WorldWideScience

Sample records for biopsy system obs

  1. Peripheral nervous system insulin resistance in ob/ob mice

    Science.gov (United States)

    2013-01-01

    Background A reduction in peripheral nervous system (PNS) insulin signaling is a proposed mechanism that may contribute to sensory neuron dysfunction and diabetic neuropathy. Neuronal insulin resistance is associated with several neurological disorders and recent evidence has indicated that dorsal root ganglion (DRG) neurons in primary culture display altered insulin signaling, yet in vivo results are lacking. Here, experiments were performed to test the hypothesis that the PNS of insulin-resistant mice displays altered insulin signal transduction in vivo. For these studies, nondiabetic control and type 2 diabetic ob/ob mice were challenged with an intrathecal injection of insulin or insulin-like growth factor 1 (IGF-1) and downstream signaling was evaluated in the DRG and sciatic nerve using Western blot analysis. Results The results indicate that insulin signaling abnormalities documented in other “insulin sensitive” tissues (i.e. muscle, fat, liver) of ob/ob mice are also present in the PNS. A robust increase in Akt activation was observed with insulin and IGF-1 stimulation in nondiabetic mice in both the sciatic nerve and DRG; however this response was blunted in both tissues from ob/ob mice. The results also suggest that upregulated JNK activation and reduced insulin receptor expression could be contributory mechanisms of PNS insulin resistance within sensory neurons. Conclusions These findings contribute to the growing body of evidence that alterations in insulin signaling occur in the PNS and may be a key factor in the pathogenesis of diabetic neuropathy. PMID:24252636

  2. Biopsy system for CT-guided biopsies

    International Nuclear Information System (INIS)

    Onik, G.; Cosman, E.; Wells, T.; Goldberg, H.I.; Moss, A.; Costello, P.; Kane, R.

    1987-01-01

    CT stereotaxic brain biopsies have made brain biopsies safe and minimally invasive. CT-guided biopsies of the body, however, have traditionally used a hand-guidance method. CT biopsy guidance systems for the body have recently become available that have similar capabilities as those of brain biopsy systems. To compare the clinical utility of stereotaxically guided biopsies with hand-guided biopsies, the authors prospectively compared 40 biopsies performed with each method. In the stereotaxic method, a localizor grid was placed on the patient to define a reference point, and a frame was used to guide the needle along the intended path. Computer software programs calculated complex paths from one scan plane to another. Although the results disclosed no significant differences in lesion size or path length between the two groups, the stereotaxically guided biopsies required 75% fewer needle manipulations to hit the intended target. Consequently, the stereotaxically guided biopsies required 40% less time and 80% fewer localization scans to find the biopsy needle than did the hand-guided biopsies

  3. Biopsy

    Science.gov (United States)

    ... Oropharynx lesion biopsy Pleural needle biopsy Polyp biopsy Rectal biopsy Renal biopsy Salivary gland biopsy Skin lesion ... Copyright 1997-2018, A.D.A.M., Inc. Duplication for commercial use must be authorized in writing ...

  4. Expression of Leptin (Ob Gene Product) in Reproductive System ...

    African Journals Online (AJOL)

    Purpose: To determine serum leptin and its ob mRNA expression both in the PCOS and non-PCOS ovary, endometrium and adipose tissue in normal or polycystic ovary syndrome (PCOS) in South Indian population. PCOS (Polycystic Ovary Syndrome) and non-PCOS subject's endometrium, ovary and adipose tissue were ...

  5. Optical diagnostics based on elastic scattering: Recent clinical demonstrations with the Los Alamos Optical Biopsy System

    Energy Technology Data Exchange (ETDEWEB)

    Bigio, I.J.; Loree, T.R.; Mourant, J.; Shimada, T. [Los Alamos National Lab., NM (United States); Story-Held, K.; Glickman, R.D. [Texas Univ. Health Science Center, San Antonio, TX (United States). Dept. of Ophthalmology; Conn, R. [Lovelace Medical Center, Albuquerque, NM (United States). Dept. of Urology

    1993-08-01

    A non-invasive diagnostic tool that could identify malignancy in situ and in real time would have a major impact on the detection and treatment of cancer. We have developed and are testing early prototypes of an optical biopsy system (OBS) for detection of cancer and other tissue pathologies. The OBS invokes a unique approach to optical diagnosis of tissue pathologies based on the elastic scattering properties, over a wide range of wavelengths, of the microscopic structure of the tissue. The use of elastic scattering as the key to optical tissue diagnostics in the OBS is based on the fact that many tissue pathologies, including a majority of cancer forms, manifest significant architectural changes at the cellular and sub-cellular level. Since the cellular components that cause elastic scattering have dimensions typically on the order of visible to near-IR wavelengths, the elastic (Mie) scattering properties will be strongly wavelength dependent. Thus, morphology and size changes can be expected to cause significant changes in an optical signature that is derived from the wavelength dependence of elastic scattering. The data acquisition and storage/display time with the OBS instrument is {approximately}1 second. Thus, in addition to the reduced invasiveness of this technique compared with current state-of-the-art methods (surgical biopsy and pathology analysis), the OBS offers the possibility of impressively faster diagnostic assessment. The OBS employs a small fiber-optic probe that is amenable to use with any endoscope, catheter or hypodermic, or to direct surface examination (e.g. as in skin cancer or cervical cancer). It has been tested in vitro on animal and human tissue samples, and clinical testing in vivo is currently in progress.

  6. Ultrasound-guided renal biopsy: experience using an automated core biopsy system.

    Science.gov (United States)

    Chan, R; Common, A A; Marcuzzi, D

    2000-04-01

    To assess the safety and efficacy of ultrasound-guided percutaneous renal biopsy using an automated core biopsy system, and to determine radiologists' accuracy in predicting sample adequacy. Ninety-five biopsies were performed on 25 native kidneys and 70 renal allografts using a 16-gauge automated, spring-loaded core biopsy device under real-time sonographic guidance. Radiologists performing the biopsy estimated the number of core samples needed to obtain an adequate specimen, based on visual inspection of each core. The final determination of the number of samples was made by a pathology technologist who attended each biopsy, based on preliminary microscopic examination of tissue cores. After each biopsy, an ultrasonographic examination was performed to search for biopsy-related hemorrhage, and a questionnaire was given to the patient to determine biopsy-related complications, which were categorized as either minor or major. The main indication for biopsy was acute renal failure (in 43.2% of biopsies). An average of 3 tissue cores per biopsy were obtained. Of the 94 patients in whom a biopsy was conducted to exclude diffuse renal disease, a mean of 12.5 glomeruli were present in each specimen. Overall, adequate tissue for diagnosis was obtained in 98.9% of cases. The radiologists' estimate of the number of core samples needed concurred with the pathology technologists' determination of sample adequacy in 88.4% of cases. A total of 26 complications occurred (in 27.4% of biopsies), consisting of 23 minor (24.2%) and 3 major (3.2%) complications. Real-time sonographic guidance in conjunction with an automated core biopsy system is a safe and accurate method of performing percutaneous renal biopsy. Routine use of sonographic examinations to search for biopsy-related complications is not indicated. Radiologists are accurate in estimating sample adequacy in most cases; however, the presence of a pathology technologist at the biopsy procedure virtually eliminates the

  7. Influences of obese (ob/ob and diabetes (db/db genotype mutations on lumber vertebral radiological and morphometric indices: Skeletal deformation associated with dysregulated systemic glucometabolism

    Directory of Open Access Journals (Sweden)

    Garris David R

    2006-02-01

    Full Text Available Abstract Background Both diabetes and obesity syndromes are recognized to promote lumbar vertebral instability, premature osteodegeneration, exacerbate progressive osteoporosis and increase the propensity towards vertebral degeneration, instability and deformation in humans. Methods The influences of single-gene missense mutations, expressing either diabetes (db/db or obese (ob/ob metabolic syndromes on vertebral maturation and development in C57BL/KsJ mice were evaluated by radiological and macro-morphometric analysis of the resulting variances in osteodevelopment indices relative to control parameters between 8 and 16 weeks of age (syndrome onset @ 4 weeks, and the influences of low-dose 17-B-estradiol therapy on vertebral growth expression evaluated. Results Associated with the indicative genotypic obesity and hyper-glycemic/-insulinemic states, both db/db and ob/ob mutants demonstrated a significant (P ≤ 0.05 elongation of total lumbar vertebrae column (VC regional length, and individual lumbar vertebrae (LV1-5 lengths, relative to control VC and LV parameters. In contrast, LV1-5 width indices were suppressed in db/db and ob/ob mutants relative to control LV growth rates. Between 8 and 16 weeks of age, the suppressed LV1-5 width indices were sustained in both genotype mutant groups relative to control osteomaturation rates. The severity of LV1-5 width osteosuppression correlated with the severe systemic hyperglycemic and hypertriglyceridemic conditions sustained in ob/ob and db/db mutants. Low-dose 17-B-estradiol therapy (E2-HRx: 1.0 ug/ 0.1 ml oil s.c/3.5 days, initiated at 4 weeks of age (i.e., initial onset phase of db/db and ob/ob expressions re-established control LV 1–5 width indices without influencing VC or LV lengths in db/db groups. Conclusion These data demonstrate that the abnormal systemic endometabolic states associated with the expression of db/db and ob/ob genomutation syndromes suppress LV 1–5 width osteomaturation

  8. Mass loss from OB supergiants in x-ray binary systems

    International Nuclear Information System (INIS)

    Alme, M.L.; Wilson, J.R.

    1975-01-01

    A study of the atmospheres of OB supergiants in x-ray binary systems indicates that when the stellar surface is close enough to the saddle in the gravitational potential to provide a mass transfer rate adequate to power a compact x-ray source, large-amplitude variations in the rate of mass flow occur. 9 references

  9. Systemic Air Embolism After CT-guided Lung Biopsy

    Science.gov (United States)

    2017-11-27

    Patients Who Underwent Percutaneous Lung Biopsy Under CT Guidance; Patients Who Presented Systemic Air Embolism After Percutaneous Lung Biopsy Under CT Guidance Depicted at the Time of the Procedure on a Whole Thoracic CT

  10. Detection of gastrointestinal cancer by elastic scattering and absorption spectroscopies with the Los Alamos Optical Biopsy System

    Energy Technology Data Exchange (ETDEWEB)

    Mourant, J.R.; Boyer, J.; Johnson, T.M.; Lacey, J.; Bigio, I.J. [Los Alamos National Lab., NM (United States); Bohorfoush, A. [Wisconsin Medical School, Milwaukee, WI (United States). Dept. of Gastroenterology; Mellow, M. [Univ. of Oklahoma Medical School, Oklahoma City, OK (United States). Dept. of Gastroenterology

    1995-03-01

    The Los Alamos National Laboratory has continued the development of the Optical Biopsy System (OBS) for noninvasive, real-time in situ diagnosis of tissue pathologies. In proceedings of earlier SPIE conferences we reported on clinical measurements in the bladder, and we report here on recent results of clinical tests in the gastrointestinal tract. With the OBS, tissue pathologies are detected/diagnosed using spectral measurements of the elastic optical transport properties (scattering and absorption) of the tissue over a wide range of wavelengths. The use of elastic scattering as the key to optical tissue diagnostics in the OBS is based on the fact that many tissue pathologies, including a majority of cancer forms, exhibit significant architectural changes at the cellular and sub-cellular level. Since the cellular components that cause elastic scattering have dimensions typically on the order of visible to near-IR wavelengths, the elastic (Mie) scattering properties will be wavelength dependent. Thus, morphology and size changes can be expected to cause significant changes m an optical signature that is derived from the wavelength-dependence of elastic scattering. Additionally, the optical geometry of the OBS beneficially enhances its sensitivity for measuring absorption bands. The OBS employs a small fiber-optic probe that is amenable to use with any endoscope or catheter, or to direct surface examination, as well as interstitial needle insertion. Data acquistion/display time is <1 second.

  11. Transjugular liver biopsy : the efficacy of quick-core biopsy needle system

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Gyoo Sik; Ahn, Byung Kwon; Lee, Sang Ouk; Chang, Hee Kyong; Oh, Kyung Seung; Huh, Jin Do; Joh, Young Duk [Kosin Medical College, Pusan (Korea, Republic of)

    1998-02-01

    To evaluate the efficacy of the Quick-Core biopsy needle system in performing transjugular liver biopsy. Between December 1995 and June 1997, eight patients underwent transjugular liver biopsy involving use of the Quick-Core biopsy needle system; the conditions involved were coagulopathy (n=4), thrombocytopenia (n=3), and ascites (n=1). Via the right internal jugular vein, the right hepatic vein was selectively catheterized with a 7-F transjugular guiding catheter, and a14-guage stiffening cannula was then inserted through this catheter; to obtain core tissue, a Quick-Core needle was then advanced into the liver parenchyma through the catheter-cannula combination. Eighteen- and 19-guage needles were used in three and five patients, respectively; specimen size, adequacy of the biopsy specimen and histologic diagnosis were determined, and complications were recorded. Biopsy was successful in all patients. The mean length of the specimen was 1.4 cm (1.0 - 1.8 cm), and all were adequate for pathologic examinations ; specific diagnosis was determined in all patients. There were two malignant neoplasms, two cases of veno-occlusive disease, and one case each of cirrhosis, fulminant hepatitis, Banti syndrome and Budd-Chiari syndrome. One patient complained of neck pain after the procedure, but no serious procedural complications were noted. Our preliminary study shows that the Quick-Core biopsy needle system is safe and provides adequate core tissues with high diagnostic yields. (author). 23 refs., 1 tab., 3 figs.

  12. Transjugular liver biopsy : the efficacy of quick-core biopsy needle system

    International Nuclear Information System (INIS)

    Jung, Gyoo Sik; Ahn, Byung Kwon; Lee, Sang Ouk; Chang, Hee Kyong; Oh, Kyung Seung; Huh, Jin Do; Joh, Young Duk

    1998-01-01

    To evaluate the efficacy of the Quick-Core biopsy needle system in performing transjugular liver biopsy. Between December 1995 and June 1997, eight patients underwent transjugular liver biopsy involving use of the Quick-Core biopsy needle system; the conditions involved were coagulopathy (n=4), thrombocytopenia (n=3), and ascites (n=1). Via the right internal jugular vein, the right hepatic vein was selectively catheterized with a 7-F transjugular guiding catheter, and a14-guage stiffening cannula was then inserted through this catheter; to obtain core tissue, a Quick-Core needle was then advanced into the liver parenchyma through the catheter-cannula combination. Eighteen- and 19-guage needles were used in three and five patients, respectively; specimen size, adequacy of the biopsy specimen and histologic diagnosis were determined, and complications were recorded. Biopsy was successful in all patients. The mean length of the specimen was 1.4 cm (1.0 - 1.8 cm), and all were adequate for pathologic examinations ; specific diagnosis was determined in all patients. There were two malignant neoplasms, two cases of veno-occlusive disease, and one case each of cirrhosis, fulminant hepatitis, Banti syndrome and Budd-Chiari syndrome. One patient complained of neck pain after the procedure, but no serious procedural complications were noted. Our preliminary study shows that the Quick-Core biopsy needle system is safe and provides adequate core tissues with high diagnostic yields. (author). 23 refs., 1 tab., 3 figs

  13. Optical diagnostics based on elastic scattering: An update of clinical demonstrations with the Optical Biopsy System

    Energy Technology Data Exchange (ETDEWEB)

    Bigio, I.J.; Boyer, J.; Johnson, T.M.; Lacey, J.; Mourant, J.R. [Los Alamos National Lab., NM (United States); Conn, R. [Lovelace Medical Center, Albuquerque, NM (United States); Bohorfoush, A. [Wisconsin Medical School, Milwaukee, WI (United States)

    1994-10-01

    The Los Alamos National Laboratory has continued the development of the Optical Biopsy System (OBS) for noninvasive, real-time in situ diagnosis of tissue pathologies. Our clinical studies have expanded since the last Biomedical Optics Europe conference (Budapest, September 1993), and we report here on the latest results of clinical tests in gastrointestinal tract. The OBS invokes a unique approach to optical diagnosis of tissue pathologies based on the elastic scattering properties, over a wide range of wavelengths, of the tissue. The use of elastic scattering as the key to optical tissue diagnostics in the OBS is based on the fact that many tissue pathologies, including a majority of cancer forms, manifest significant architectural changes at the cellular and sub-cellular level. Since the cellular components that cause elastic scattering have dimensions typically on the order of visible to near-IR wavelengths, the elastic (Mie) scattering properties will be wavelength dependent. Thus, morphology and size changes can be expected to cause significant changes in an optical signature that is derived from the wavelength-dependence of elastic scattering. The OBS employs a small fiberoptic probe that is amenable to use with any endoscope or catheter, or to direct surface examination. The probe is designed to be used in optical contact with the tissue under examination and has separate illuminating and collecting fibers. Thus, the light that is collected and transmitted to the analyzing spectrometer must first scatter through a small volume of the tissue before entering the collection fiber(s). Consequently, the system is also sensitive to the optical absorption spectrum of the tissue, over an effective operating range of <300 to 950 nm, and such absorption adds valuable complexity to the scattering spectral signature.

  14. MUG-OBS - Multiparameter Geophysical Ocean Bottom System : a new instrumental approach to monitor earthquakes.

    Science.gov (United States)

    hello, yann; Charvis, Philippe; Yegikyan, Manuk; verfaillie, Romain; Rivet, Diane

    2016-04-01

    Real time monitoring of seismic activity is a major issue for early warning of earthquakes and tsunamis. It can be done using regional scale wired nodes, such as Neptune in Canada and in the U.S, or DONET in Japan. Another approach to monitor seismic activity at sea is to deploying repeatedly OBS array like during the amphibious Cascadia Initiative (four time 1-year deployments), the Japanese Pacific Array (broadband OBSs "ocean-bottom broadband dispersion survey" with 2-years autonomy), the Obsismer program in the French Lesser Antilles (eight time 6-months deployments) and the Osisec program in Ecuador (four time 6-months deployments). These autonomous OBSs are self-recovered or recovered using an ROV. These systems are costly including ship time, and require to recover the OBS before to start working on data. Among the most recent alternative we developed a 3/4 years autonomy ocean bottom system with 9 channels (?) allowing the acquisition of different seismic or environmental parameters. MUG-OBS is a free falling instrument rated down to 6000 m. The installation of the sensor is monitored by acoustic commands from the surface and a health bulletin with data checking is recovered by acoustic during the installation. The major innovation is that it is possible to recover the data any time on demand (regularly every 6-months or after a crisis) using one of the 6 data-shuttles released from the surface by acoustic command using a one day fast cruise boat of opportunity. Since sensors stayed at the same location for 3 years, it is a perfect tool to monitor large seismic events, background seismic activity and aftershock distribution. Clock, drift measurement and GPS localization is automatic when the shuttle reaches the surface. For remote areas, shuttles released automatically and a seismic events bulletin is transmitted. Selected data can be recovered by two-way Iridium satellite communication. After a period of 3 years the main station is self-recovered by

  15. Optical Systems of Biopsy: The Invisible Eye

    Directory of Open Access Journals (Sweden)

    Kriti Bagri-Manjrekar

    2012-01-01

    Full Text Available The exploration of new methods and techniques for the diagnosis of malignant tumours has always attracted the attention of scientists. The development of adjunct tools to facilitate the non invasive screening of high risk lesions in real time has the potential to significantly improve our ability to reduce the dismal morbidity and mortality of oral cancer. Despite easy accessibility of the oral cavity to examination, there is no satisfactory method to adequately screen and detect precancers non-invasively. The current method of oral cancer diagnosis clinically relies heavily on visual examination of the oral cavity. However, discerning potentially malignant and early malignant lesions from common benign inflammatory conditions can be difficult at times. There is a need for an objective method that could provide real- time results and be routinely applied to a large population. Though science is yet to present such a perfect technique, Optical Biopsy Systems developed using knowledge of light and tissue interaction, can provide a plausible option.

  16. MODELING THE RADIO EMISSION FROM Cyg OB2 NO. 5: A QUADRUPLE SYSTEM?

    International Nuclear Information System (INIS)

    Kennedy, M.; Dougherty, S. M.; Fink, A.; Williams, P. M.

    2010-01-01

    Fifty observations at frequencies between 1.4 GHz and 43 GHz of the 6.6 day O6.5-7+O5.5-6 binary Cyg OB2 No. 5 using the Very Large Array over 20 years are re-examined. The aim is to determine the location and character of the previously detected variable radio emission. The radio emission from the system consists of a primary component that is associated with the binary, and a non-thermal source (NE), 0.''8 to the NE of the binary that has been ascribed to a wind-collision region (WCR) between the stellar winds of the binary and that of a B-type star (Star D) to the NE. Previous studies have not accounted for the potential contribution of NE to the total radio emission, most especially in observations where the primary and NE sources are not resolved as separate sources. NE shows no evidence of variation in 23 epochs where it is resolved separately from the primary radio component, demonstrating that the variable emission arises in the primary component. Since NE is non-variable, the radio flux from the primary can now be well determined for the first time, most especially in observations that do not resolve both the primary and NE components. The variable radio emission from the primary component has a period of 6.7 ± 0.3 years which is described by a simple model of a non-thermal source orbiting within the stellar wind envelope of the binary. Such a model implies the presence of a third, unresolved stellar companion (Star C) orbiting the 6.6 day binary with a period of 6.7 years and independent of Star D to the NE. The variable non-thermal emission arises from either a WCR between Star C and the binary system, or possibly from Star C directly. The model gives a mass-loss rate of 3.4 x 10 -5 M sun yr -1 for Cyg OB2 No. 5, unusually high for an Of supergiant and comparable to that of WR stars, and consistent with an unusually strong He I 1.083 μm emission line, also redolent of WR stars. An examination of radial velocity observations available from the

  17. Functional quality of MR-compatible automatic biopsy guns compared with conventional ferromagnetic biopsy systems. An in vitro study

    International Nuclear Information System (INIS)

    Langen, H.J.; Landwehr, P.

    2001-01-01

    Comparative evaluation of specimens obtained with different MR-compatible biopsy systems and a conventional ferromagnetic system. Methods: Biopsies of a pig liver were performed post-mortem with three different MR-compatible (Somatex; E-Z-EM; Daum) and one conventional biopsy system (Somatex), five with each device. The specimens were measured and the histopathological quality was graded on a scale from 0 (no tissue) to 9 (best). The tip of the needle was examined with an electron microscope before and after biopsy to demonstrate abrasion. Results: The histopathological score between the first and fifth specimen taken with one biopsy device showed no significant difference. The conventional system yielded significantly better results in nearly all categories (p 2 ) were significantly smaller than those from the conventional system (9.98 mm 2 ). The needle tip abrasion of the different biopsy systems determined by electron microscopy showed no substantial difference. (orig.) [de

  18. Growth of yttrium iron garnet single crystals in Na2O-B2O3 flux system in air

    International Nuclear Information System (INIS)

    Bandyopadhyay, Tarun; Saha, Prasenjit

    1977-01-01

    Detailed studies of growth of yttrium iron garnet (YIG) in the flux system Na 2 O-B 2 O 3 were made to delineate the phase stability regions of YIG and the neighbouring crystalline phases, and a tentative working diagram of Na 2 O-B 2 O 3 -YIG in air was drawn from the results of small batch crystal growth runs and solubility studies. The occurrence of a rather narrow field of YIG crystallization in this system was explained on the basis of relative solubilities of different oxides constituting YIG. Several long-time growth runs with some typical compositions were carried out in this system to evaluate its suitability for bulk growth of YIG crystals. The system, although possessing some inherent advantages, was found to suffer from limitations because the maximum size of the self-nucleated crystals grown hardly exceeded 2.00 mm. (author)

  19. Radionuclides in the Ob/Irtysh river system and their contribution to pollution of the Arctic

    International Nuclear Information System (INIS)

    Trapeznikov, A.; Pozolotina, V.; Trapeznikova, V.; Yushkov, P.; Polikarpov, G.; Aarkrog, A.; Nielsen, S.P.

    1995-01-01

    The aims of this study were: 1) to continue the investigation of distribution of radionuclides in the principal components of the Techa river, and 2) to get the first estimate of the contamination of sediments of the Iset, Tobol, Irtysh and Ob rivers. The samples from the Irtysh river were collected in 1993 nine km in front of confluence of the Irtysh with the Ob river. The mean Cs-137 concentration in the sediments did not show any clear trend. The sediments from the Ob river were collected in 1992 near Labitnangi, situated about 300 km from the outlet of the Ob into the Kara Sea. In 1994 samples were collected five km in front of and five km after confluence with the Irtysh river. All results are summarized in a table. It appears that the Cs-137 levels in the Ob sediments, before and after confluence with Irtysh, do not change significantly. It is difficult to see any systematic changes in Cs-137 concentrations with depth. In some cases the top five cm show higher concentrations than the deeper layers. 7 refs., 1 tab

  20. Comparison of Battery-Powered and Manual Bone Biopsy Systems for Core Needle Biopsy of Sclerotic Bone Lesions.

    Science.gov (United States)

    Cohen, Micah G; McMahon, Colm J; Kung, Justin W; Wu, Jim S

    2016-05-01

    The purpose of this study was to compare manual and battery-powered bone biopsy systems for diagnostic yield and procedural factors during core needle biopsy of sclerotic bone lesions. A total of 155 consecutive CT-guided core needle biopsies of sclerotic bone lesions were performed at one institution from January 2006 to November 2014. Before March 2012, lesions were biopsied with manual bone drill systems. After March 2012, most biopsies were performed with a battery-powered system and either noncoaxial or coaxial biopsy needles. Diagnostic yield, crush artifact, CT procedure time, procedure radiation dose, conscious sedation dose, and complications were compared between the manual and battery-powered core needle biopsy systems by Fisher exact test and t test. One-way ANOVA was used for subgroup analysis of the two battery-powered systems for procedure time and radiation dose. The diagnostic yield for all sclerotic lesions was 60.0% (93/155) and was significantly higher with the battery-powered system (73.0% [27/37]) than with the manual systems (55.9% [66/118]) (p = 0.047). There was no significant difference between the two systems in terms of crush artifact, procedure time, radiation dose, conscious sedation administered, or complications. In subgroup analysis, the coaxial battery-powered biopsies had shorter procedure times (p = 0.01) and lower radiation doses (p = 0.002) than the coaxial manual systems, but the noncoaxial battery-powered biopsies had longer average procedure times and higher radiation doses than the coaxial manual systems. In biopsy of sclerotic bone lesions, use of a battery-powered bone drill system improves diagnostic yield over use of a manual system.

  1. Stormram 4: An MR Safe Robotic System for Breast Biopsy

    NARCIS (Netherlands)

    Groenhuis, Vincent; Siepel, Françoise Jeanette; Veltman, Jeroen; van Zandwijk, Jordy Kristian; Stramigioli, Stefano

    2018-01-01

    Suspicious lesions in the breast that are only visible on magnetic resonance imaging (MRI) need to be biopsied under MR guidance with high accuracy and efficiency for accurate diagnosis. The aim of this study is to present a novel robotic system, the Stormram 4, and to perform preclinical tests in

  2. HD 144548: A young triply eclipsing system in the Upper Scorpius OB association

    Science.gov (United States)

    Alonso, R.; Deeg, H. J.; Hoyer, S.; Lodieu, N.; Palle, E.; Sanchis-Ojeda, R.

    2015-12-01

    The star HD 144548 (=HIP 78977; TYP 6212-1273-1) has been known as a detached eclipsing binary and a bona-fide member of the Upper Scorpius OB association. Continuous photometry from the K2 mission on Campaign Two has revealed the presence of additional eclipses due to the presence of a third star in the system. These are explained by a system composed of the two previously known members of the eclipsing system (Ba and Bb) with a period of 1.63 d, orbiting around an F7-F8V star with a period of 33.945 ± 0.002 d in an eccentric orbit (eA = 0.2652 ± 0.0003). The timing of the eclipses of Ba and Bb reveals the same 33.9 d periodicity, which we interpret as the combination of a light time effect combined with dynamical perturbations on the close system. Here we combine radial velocities and analytical approximations for the timing of the eclipses to derive masses and radii for the three components of the system. We obtain a mass of 1.44 ± 0.04 M⊙ and radius of 2.41 ± 0.03 R⊙ for the A component, and almost identical masses and radii of about 0.96 M⊙ and 1.33 R⊙ for each of the two components of the close binary. HD 144548 is the first triply eclipsing system for which radial velocities of all components could be measured. Partially based on observations made with the Italian Telescopio Nazionale Galileo (TNG) operated by the Fundación Galileo Galilei of the INAF, the Nordic Optical Telescope, operated by the Nordic Optical Telescope Scientific Association, and the William Herschel Telescope (programme DDT58 - PI Lodieu) operated by the Isaac Newton Group on the island of La Palma at the Spanish Observatorio Roque de los Muchachos of the IAC. This paper includes data collected by the Kepler mission. Funding for the Kepler mission is provided by the NASA Science Mission directorate.Appendices are available in electronic form at http://www.aanda.org

  3. More accurate definition of liquation dome in Na2O-B2O3-SiO2 system

    International Nuclear Information System (INIS)

    Alekseeva, Z.D.; Mazurin, O.V.; Aver'yanov, V.I.; Galakhov, F.Ya.

    1977-01-01

    The liquation region in the system Na 2 O-B 2 O 3 -SiO 2 was investigated. The liquation temperatures were determined by the boundary of disappearance of opalescence in specimens with pre-induced opalescence. Extrapolation of the concentration dependences of the liquation temperature along sections with a constant SiO 2 content to a point indicates that with a SiO 2 content of 20-40% the liquation boundary in the system B 2 O 3 -SiO 2 hardly lies above 450 deg C

  4. Application of a New Guiding System in Percutaneous Biopsies

    International Nuclear Information System (INIS)

    Petsas, Theodore; Tsota, Irene; Kalogeropoulou, Christina P.; Liatsikos, Evangelos N.

    2007-01-01

    We herein describe the application of a new guiding system designed for percutaneous biopsies. The guiding system set is composed of a 0.41 mm (27G) stainless steel guide stylet and a 22G Chiba needle. Following the initial insertion of the Chiba needle, the stylet is advanced via the needle toward the lesion. The stylet serves either as a guide for the Chiba needle or as an exchange wire for the introduction of larger or cutting biopsy needles. The stylet can also be curved prior to its insertion to facilitate access to lesions which require needle redirection. The technique was applied to 117 cases (54 thoracic, 31 abdominal, 21 pelvic, and 11 vertebral lesions.) The main advantage of the stylet is its small diameter, rendering it atraumatic and permitting multiple punctures for the successful final targeting of the lesion. With this guiding set we achieved targeting of difficult lesions. Furthermore, larger needles were more easily introduced in locations that posed technical difficulties. No major complications were observed. The complication rate was comparable to that of the conventional biopsy technique. The technique using the guide stylet was easily performed and could be applied to almost all organs

  5. In-Bore MR-Guided Biopsy Systems and Utility of PI-RADS.

    Science.gov (United States)

    Fütterer, Jurgen J; Moche, Michael; Busse, Harald; Yakar, Derya

    2016-06-01

    A diagnostic dilemma exists in cases wherein a patient with clinical suspicion for prostate cancer has a negative transrectal ultrasound-guided biopsy session. Although transrectal ultrasound-guided biopsy is the standard of care, a paradigm shift is being observed. In biopsy-naive patients and patients with at least 1 negative biopsy session, multiparametric magnetic resonance imaging (MRI) is being utilized for tumor detection and subsequent targeting. Several commercial devices are now available for targeted prostate biopsy ranging from transrectal ultrasound-MR fusion biopsy to in bore MR-guided biopsy. In this review, we will give an update on the current status of in-bore MRI-guided biopsy systems and discuss value of prostate imaging-reporting and data system (PIRADS).

  6. Stormram 4: An MR Safe Robotic System for Breast Biopsy.

    Science.gov (United States)

    Groenhuis, Vincent; Siepel, Françoise J; Veltman, Jeroen; van Zandwijk, Jordy K; Stramigioli, Stefano

    2018-05-21

    Suspicious lesions in the breast that are only visible on magnetic resonance imaging (MRI) need to be biopsied under MR guidance with high accuracy and efficiency for accurate diagnosis. The aim of this study is to present a novel robotic system, the Stormram 4, and to perform preclinical tests in an MRI environment. Excluding racks and needle, its dimensions are 72 × 51 × 40 mm. The Stormram 4 is driven by two linear and two curved pneumatic stepper motors. The linear motor is capable of exerting 63 N of force at a pressure of 0.65 MPa. In an MRI environment the maximum observed stepping frequency is 30 Hz (unloaded), or 8 Hz when full force is needed. The Stormram 4's mean positioning error is 0.73 ± 0.47 mm in free air, and 1.29 ± 0.59 mm when targeting breast phantoms in MRI. Excluding the off-the-shelf needle, the robot is inherently MR safe. The robot is able to accurately target lesions under MRI guidance, reducing tissue damage and risk of false negatives. These results are promising for clinical experiments, improving the quality of healthcare in the field of MRI-guided breast biopsies.

  7. Percutaneous biopsy of non-palpable breast lesions with the advanced breast biopsy instrumentation (ABBI): analysis of indication strategies; Perkutane stereotaktische Biopsie nicht palpabler Mammalaesionen mit dem Advanced Breast Biopsy Instrumentation (ABBI) System: kritische Evaluation der Indikationsstellung

    Energy Technology Data Exchange (ETDEWEB)

    Wedegaertner, U.; Otto, U.; Buitrago-Tellez, C.; Bremerich, J.; Bongartz, G. [Basel Univ. (Switzerland). Inst. fuer Diagnostische Radiologie; Oertli, D. [Basel Univ. (Switzerland). Inst. fuer Chirurgie; Torhorst, J. [Basel Univ. (Switzerland). Inst. fuer Pathologie

    2001-03-01

    Purpose: To compare the indications for biopsy with and without the use of the Breast Imaging Reporting and Data System. Material and methods: Biopsies using the ABBI were performed in 62 patients with 64 non-palpable evident mammographic lesions. The initial decision for biopsy was made by non-radiologists due to suspicious microcalcifications (n=53) and masses (n=11). The indication was retrospectively reassessed by adopting the BI-RADS classification by three radiologists in consensus. The positive predictive value (PPV) of both indication strategies was assessed and compared. Results: Biopsies adopting ABBI were performed without major side-effects and were diagnostic. Carcinoma was present in 14 lesions: nine specimens were diagnosed as DCIS and five as invasive carcinomas. For the 50 benign lesions histology revealed mastopathies (26/50) and fibroadenomas (8/50) as the most frequent diagnosis. The positive predictive value (PPV) for the initial indication was 22%, whereas PPV for BI-RADS based indications (categories 4 and 5) was 31%. Conclusion: ABBI enables stereotactically-guided procedures that result in representative and diagnostic biopsies. Standardized criteria like BI-RADS improve the PPV and should be a mandatory part of mammographic evaluation. Radiologists should remain involved in the decision making. (orig.) [German] Ziel: Perkutane stereotaktische Biopsien mit dem ABBI stellen eine neue Alternative in der Abklaerung nicht palpabler Mammalaesionen dar. Es soll die Indikationsstellung mit und ohne Anwendung des Breast Imaging Reporting and Data System (BI-RADS) analysiert werden. Material und Methoden: Insgesamt wurde bei 62 Patientinnen mit 64 Laesionen eine Biopsie mit dem ABBI System durchgefuehrt. Die primaere Indikation zur ABBI Biopsie wurde von Nicht-Radiologen aufgrund von Mikrokalzifikationen in 53 Faellen und einer unklaren Verdichtung in 11 Faellen gestellt. Zusaetzlich erfolgte eine retrospektive Indikationsstellung der biopsierten

  8. Nephrogenic systemic fibrosis: Review of 408 biopsy-confirmed cases

    Directory of Open Access Journals (Sweden)

    Zhitong Zou

    2011-01-01

    Full Text Available Nephrogenic systemic fibrosis (NSF has now been virtually eliminated by the discovery of its association with gadolinium-based contrast agents (GBCAs and the consequent reduced use of GBCA-enhanced magnetic resonance imaging (MRI in severe renal failure patients. This review of 408 biopsy-confirmed cases shows how to minimize NSF risk when performing GBCA-enhanced MRI or magnetic resonance angiography. The absence of any NSF cases in patients less than 8 years old or greater than 87 years old suggests that infants and elderly patients are already protected. Limiting GBCA dose to a maximum of 0.1 mMol/kg, dialyzing dialysis patients quickly following GBCA administration, delaying administration of GBCA in acute renal failure until after renal function returns or dialysis is initiated, and avoiding nonionic linear GBCA in renal failure patients, especially when there are pro-inflammatory conditions, appear to have reduced NSF risk to the point where safe GBCA-enhanced MRI is possible in most patients.

  9. X-RAY EMISSION FROM THE DOUBLE-BINARY OB-STAR SYSTEM QZ CAR (HD 93206)

    International Nuclear Information System (INIS)

    Parkin, E. R.; Naze, Y.; Rauw, G.; Broos, P. S.; Townsley, L. K.; Pittard, J. M.; Moffat, A. F. J.; Oskinova, L. M.; Waldron, W. L.

    2011-01-01

    X-ray observations of the double-binary OB-star system QZ Car (HD 93206) obtained with the Chandra X-ray Observatory over a period of roughly 2 years are presented. The respective orbits of systems A (O9.7 I+b2 v, P A = 21 days) and B (O8 III+o9 v, P B = 6 days) are reasonably well sampled by the observations, allowing the origin of the X-ray emission to be examined in detail. The X-ray spectra can be well fitted by an attenuated three-temperature thermal plasma model, characterized by cool, moderate, and hot plasma components at kT ≅ 0.2, 0.7, and 2 keV, respectively, and a circumstellar absorption of ≅0.2 x 10 22 cm -2 . Although the hot plasma component could be indicating the presence of wind-wind collision shocks in the system, the model fluxes calculated from spectral fits, with an average value of ≅7 x 10 -13 erg s -1 cm -2 , do not show a clear correlation with the orbits of the two constituent binaries. A semi-analytical model of QZ Car reveals that a stable momentum balance may not be established in either system A or B. Yet, despite this, system B is expected to produce an observed X-ray flux well in excess of the observations. If one considers the wind of the O8 III star to be disrupted by mass transfer, the model and observations are in far better agreement, which lends support to the previous suggestion of mass transfer in the O8 III + o9 v binary. We conclude that the X-ray emission from QZ Car can be reasonably well accounted for by a combination of contributions mainly from the single stars and the mutual wind-wind collision between systems A and B.

  10. Switching performance of OBS network model under prefetched real traffic

    Science.gov (United States)

    Huang, Zhenhua; Xu, Du; Lei, Wen

    2005-11-01

    Optical Burst Switching (OBS) [1] is now widely considered as an efficient switching technique in building the next generation optical Internet .So it's very important to precisely evaluate the performance of the OBS network model. The performance of the OBS network model is variable in different condition, but the most important thing is that how it works under real traffic load. In the traditional simulation models, uniform traffics are usually generated by simulation software to imitate the data source of the edge node in the OBS network model, and through which the performance of the OBS network is evaluated. Unfortunately, without being simulated by real traffic, the traditional simulation models have several problems and their results are doubtable. To deal with this problem, we present a new simulation model for analysis and performance evaluation of the OBS network, which uses prefetched IP traffic to be data source of the OBS network model. The prefetched IP traffic can be considered as real IP source of the OBS edge node and the OBS network model has the same clock rate with a real OBS system. So it's easy to conclude that this model is closer to the real OBS system than the traditional ones. The simulation results also indicate that this model is more accurate to evaluate the performance of the OBS network system and the results of this model are closer to the actual situation.

  11. Borate mineral assemblages in the system Na2OCaOMgOB2O3H2O

    Science.gov (United States)

    Christ, C.L.; Truesdell, A.H.; Erd, Richard C.

    1967-01-01

    he significant known hydrated borate mineral assemblages (principally of the western United States) in the system Na2OCaOz.sbnd;MgOB2O3H2O are expressible in three ternary composition diagrams. Phase rule interpretation of the diagrams is consistent with observation, if the activity of H2O is generally considered to be determined by the geologic environment. The absence of conflicting tie-lines on a diagram indicates that the several mineral assemblages of the diagram were formed under relatively narrow ranges of temperature and pressure. The known structural as well as empirical formulas for the minerals are listed, and the more recent (since 1960) crystal structure findings are discussed briefly. Schematic Gibbs free energy-composition diagrams based on known solubility-temperature relations in the systems Na2B4O7-H2O and Na2B4O7-NaCl-H2O, are highly useful in the interpretation and prediction of the stability relations in these systems; in particular these diagrams indicate clearly that tincalconite, although geologically important, is everywhere a metastable phase. Crystal-chemical considerations indicate that the same thermodynamic and kinetic behavior observed in the Na2B4O7-H2O system will hold in the Ca2B6O11-H2O system. This conclusion is confirmed by the petrologic evidence. The chemical relations among the mineral assemblages of a ternary diagram are expressed by a schematic "activity-activity" diagram. These activity-activity diagrams permit the tracing-out of the paragenetic sequences as a function of changing cation and H2O activities. ?? 1967.

  12. Determination of OB/OD/SF Emission Factors Using Unmanned Aerial Systems

    Science.gov (United States)

    A presentation to the Demilitarization Symposium. This proposal will present the methods of tethered aerostat and unmanned aerial system for collection of plume samples and determination of emission factors form open burning, open detonation, and static firing for weapon demilita...

  13. Development and implementation of an automated system to exchange attenuators of the OB85/1 gamma irradiator

    International Nuclear Information System (INIS)

    Silva Junior, Iremar A.; Ramos, Marcio A.G.; Carvalho, Valdir S.; Diniz, Raphael E.; Cescon, Claudinei T.; Vivolo, Vitor; Potiens, Maria da Penha A.

    2011-01-01

    In order to improve the calibration process of portable detectors of the Instrument Calibration Laboratory of IPEN, an automated system to exchange the attenuators of the OB85/1 irradiator system was developed. This automation was developed following this sequence: (i) development of the device with the cooperation of the IPEN Sector of Projects, using the Solid Edge software to design the mechanical part of the exchanging device of the attenuators, in 3D; (ii) simulation with the Festo's FluidSim software to define the pneumatic components and their respective actuators; (iii) machining and assembly of mechanical parts; (iv) assembly of pneumatic components and their actuators, like magnetic pneumatic cylinders, which allow the use of magnetic sensors, used to confirm the attenuators opened or closed positions: actuators 5/2 each, with double solenoid; (v) assembly of the control panel for operating the device remotely from the operating room. With this automation, the technicians in charge of the detectors calibration and research testing will have no hand contact with lead attenuators, improving the calibration process due to the decrease in time spent with manual shift from the attenuators and avoiding accidents, like the fall of the lead attenuators. It has been a concern of the LCI-IPEN group the decrease in the time spent by the technicians in the calibration room controlled areas should follow the recommendations of the radiological protection rules, which recommend the shortest time possible of workers in these areas. Automated systems have, usually, a better rate of reproducibility, due to the small participation by the system operator, so the LCI-IPEN is following the trend of several laboratories and automating its processes. (author)

  14. Leptin differentially regulates STAT3 activation in the ob/ob mice adipose mesenchymal stem cells

    Science.gov (United States)

    Leptin-deficient genetically obese ob/ob mice exhibit adipocyte hypertrophy and hyperplasia as well as elevated adipose tissue and systemic inflammation. Studies have shown that multipotent stem cells isolated from adult adipose tissue can differentiate into adipocytes ex vivo and thereby contribute...

  15. Percutaneous CT-guided biopsy of the musculoskeletal system: Results of 2027 cases

    International Nuclear Information System (INIS)

    Rimondi, Eugenio; Rossi, Giuseppe; Bartalena, Tommaso; Ciminari, Rosanna; Alberghini, Marco; Ruggieri, Pietro; Errani, Costantino; Angelini, Andrea; Calabro, Teresa; Abati, Caterina Novella; Balladelli, Alba; Tranfaglia, Cristina; Mavrogenis, Andreas F.; Vanel, Daniel; Mercuri, Mario

    2011-01-01

    Introduction: Biopsy of the musculoskeletal system is useful in the management of bone lesions particularly in oncology but they are often challenging procedures with a significant risk of complications. Computed tomography (CT)-guided needle biopsies may decrease these risks but doubts still exist about their diagnostic accuracy. This retrospective analysis of the experience of a single institution with percutaneous CT-guided biopsy of musculoskeletal lesions evaluates the results of these biopsies for bone lesions either in the appendicular skeleton or in the spine, and defines indications. Materials and methods: We reviewed the results of 2027 core needle biopsies performed over the past 18 years at the authors' institution. The results obtained are subject of this paper. Results: In 1567 cases the correct diagnosis was made with the first CT-guided needle biopsy (77.3% accuracy rate), in 408 cases the sample was not diagnostic and in 52 inadequate. Within 30 days these 408 patients underwent another biopsy, which was diagnostic in 340 cases with a final diagnostic accuracy of 94%. Highest accuracy rates were obtained in primary and secondary malignant lesions. Most false negative results were found in cervical lesions and in benign, pseudotumoral, flogistic, and systemic pathologies. There were 22 complications (18 transient paresis, 3 haematomas, 1 retroperitoneal haematoma) which had no influence on the treatment strategy, nor on patient outcome. Conclusion: This technique is reliable and safe and should be considered nowadays the gold standard for biopsies of the musculoskeletal system.

  16. Retrospective 5-year analysis of MR-guided biopsies in a low-field MR system

    International Nuclear Information System (INIS)

    Zangos, Stephan; Mueller, C.; Mayer, F.; Naguib, N.N.; Nour-Eldin, N.E.A.; Herzog, C.; Hammerstingl, R.M.; Thalhammer, A.; Mack, M.G.; Vogl, T.J.; Eichler, K.; Hansmann, M.L.

    2009-01-01

    Purpose: The purpose of this study was to evaluate the safety and clinical value of MR-guided biopsies in an open 0.2 T low-field system. Materials and methods: A total of 322 patients with suspicious lesions of different body regions were biopsied in a low-field MRI system (0.2 T, Concerto, Siemens). The procedures were guided using T1-weighted Flash sequences (TR/TE = 100/9; 70 ). The lesions were repeatedly biopsied using the coaxial technique with a 15-gauge (diameter 2 mm) puncture needle. Complications and biopsy findings were analyzed retrospectively. Results: In all cases the biopsy procedures were successfully performed with MR guidance. In 298 patients diagnosis was able to be confirmed on the basis of the probes. The clinical follow-up showed that in 24 patients the lesions were missed by MR-guided biopsy. From this a sensitivity of 86%, a specificity of 87% and an accuracy of 93% were calculated. In two patients major complications were observed (morbidity rate 0.6%). Conclusion: MR-guided biopsy can be performed safely and precisely in a low-field MR system and are a supplement to US or CT-guided biopsies. (orig.)

  17. Leptin differentially regulate STAT3 activation in ob/ob mouse adipose mesenchymal stem cells

    Directory of Open Access Journals (Sweden)

    Zhou Zhou

    2012-12-01

    Full Text Available Abstract Background Leptin-deficient ob/ob mice exhibit adipocyte hypertrophy and hyperplasia as well as elevated adipose tissue and systemic inflammation. Multipotent stem cells isolated from adult adipose tissue can differentiate into adipocytes ex vivo and thereby contribute toward increased adipocyte cell numbers, obesity, and inflamm ation. Currently, information is lacking regarding regulation of adipose stem cell numbers as well as leptin-induced inflammation and its signaling pathway in ob/ob mice. Methods Using leptin deficient ob/ob mice, we investigated whether leptin injection into ob/ob mice increases adipose stem cell numbers and adipose tissue inflammatory marker MCP-1 mRNA and secretion levels. We also determined leptin mediated signaling pathways in the adipose stem cells. Results We report here that adipose stem cell number is significantly increased following leptin injection in ob/ob mice and with treatment of isolated stem cells with leptin in vitro. Leptin also up-regulated MCP-1 secretion in a dose- and time-dependent manner. We further showed that increased MCP-1 mRNA levels were due to increased phosphorylation of Signal Transducer and Activator of Transcription 3 (STAT3 Ser727 but not STAT3 Tyr705 phosphorylation, suggesting differential regulation of MCP-1 gene expression under basal and leptin-stimulated conditions in adipose stem cells. Conclusions Taken together, these studies demonstrate that leptin increases adipose stem cell number and differentially activates STAT3 protein resulting in up-regulation of MCP-1 gene expression. Further studies of mechanisms mediating adipose stem cell hyperplasia and leptin signaling in obesity are warranted and may help identify novel anti-obesity target strategies.

  18. Metabolic and hepatic effects of liraglutide, obeticholic acid and elafibranor in diet-induced obese mouse models of biopsy-confirmed nonalcoholic steatohepatitis

    DEFF Research Database (Denmark)

    Tølbøl, Kirstine S; Kristiansen, Maria Nb; Hansen, Henrik H

    2018-01-01

    AIM: To evaluate the pharmacodynamics of compounds in clinical development for nonalcoholic steatohepatitis (NASH) in obese mouse models of biopsy-confirmed NASH. METHODS: Male wild-type C57BL/6J mice (DIO-NASH) and Lep ob/ob (ob/ob-NASH) mice were fed a diet high in trans-fat (40%), fructose (20......%) and cholesterol (2%) for 30 and 21 wk, respectively. Prior to treatment, all mice underwent liver biopsy for confirmation and stratification of liver steatosis and fibrosis, using the nonalcoholic fatty liver disease activity score (NAS) and fibrosis staging system. The mice were kept on the diet and received...... by quantitative liver histology, including percent fractional area of liver fat, galectin-3, and collagen 1a1. RESULTS: Liraglutide and elafibranor, but not OCA, reduced body weight in both models. Liraglutide improved steatosis scores in DIO-NASH mice only. Elafibranor and OCA reduced histopathological scores...

  19. A needle guidance system for biopsy and therapy using two-dimensional ultrasound

    International Nuclear Information System (INIS)

    Bluvol, Nathan; Sheikh, Allison; Kornecki, Anat; Del Rey Fernandez, David; Downey, Donal; Fenster, Aaron

    2008-01-01

    Image-guided needle biopsies are currently used to provide a definitive diagnosis of breast cancer; however, difficulties in tumor targeting exist as the ultrasound (United States) scan plane and biopsy needle must remain coplanar throughout the procedure to display the actual needle tip position. The additional time associated with aligning and maintaining this coplanar relationship results in increased patient discomfort. Biopsy procedural efficiency is further hindered since needle pathway interpretation is often difficult, especially for needle insertions at large depths that usually require multiple reinsertions. The authors developed a system that would increase the speed and accuracy of current breast biopsy procedures using readily available two-dimensional (2D) US technology. This system is composed of a passive articulated mechanical arm that attaches to a 2D US transducer. The arm is connected to a computer through custom electronics and software, which were developed as an interface for tracking the positioning of the mechanical components in real time. The arm couples to the biopsy needle and provides visual guidance for the physician performing the procedure in the form of a real-time projected needle pathway overlay on an US image of the breast. An agar test phantom, with stainless steel targets interspersed randomly throughout, was used to validate needle trajectory positioning accuracy. The biopsy needle was guided by both the software and hardware components to the targets. The phantom, with the needle inserted and device decoupled, was placed in an x-ray stereotactic mammography (SM) machine. The needle trajectory and bead target locations were determined in three dimensions from the SM images. Results indicated a mean needle trajectory accuracy error of 0.75±0.42 mm. This is adequate to sample lesions that are <2 mm in diameter. Chicken tissue test phantoms were used to compare core needle biopsy procedure times between experienced radiologists

  20. Find an Ob-Gyn

    Science.gov (United States)

    ... Management Education & Events Advocacy For Patients About ACOG Find an Ob-Gyn Home About ACOG Find an Ob-Gyn Page Navigation ▼ About Us ACOG ... Districts ACOG Sections Careers at ACOG Contact Us Find an Ob-Gyn Search by State Search by ...

  1. MULTI-EPOCH VERY LONG BASELINE ARRAY OBSERVATIONS OF THE COMPACT WIND-COLLISION REGION IN THE QUADRUPLE SYSTEM Cyg OB2 no. 5

    Energy Technology Data Exchange (ETDEWEB)

    Dzib, Sergio A.; Rodriguez, Luis F.; Loinard, Laurent; Ortiz-Leon, Gisela N.; Araudo, Anabella T. [Centro de Radiostronomia y Astrofisica, Universidad Nacional Autonoma de Mexico, Morelia 58089 (Mexico); Mioduszewski, Amy J., E-mail: s.dzib@crya.unam.mx [National Radio Astronomy Observatory, 1003 Lopezville Road, Socorro, NM 87801 (United States)

    2013-02-15

    We present multi-epoch Very Long Base Array observations of the compact wind-collision region in the Cyg OB2 no. 5 system. These observations confirm the arc-shaped morphology of the emission reported earlier. The total flux as a function of time is roughly constant when the source is 'on', but falls below the detection limit as the wind-collision region approaches periastron in its orbit around the contact binary at the center of the system. In addition, at one of the 'on' epochs, the flux drops to about a fifth of its average value. We suggest that this apparent variation could result from the inhomogeneity of the wind that hides part of the flux rather than from an intrinsic variation. We measured a trigonometrical parallax, for the most compact radio emission of 0.61 {+-} 0.22 mas, corresponding to a distance of 1.65 {sup +0.96} {sub -0.44} kpc, in agreement with recent trigonometrical parallaxes measured for objects in the Cygnus X complex. Using constraints on the total mass of the system and orbital parameters previously reported in the literature, we obtain two independent indirect measurements of the distance to the Cyg OB2 no. 5 system, both consistent with 1.3-1.4 kpc. Finally, we suggest that the companion star responsible for the wind interaction, yet undetected, is of spectral type between B0.5 and O8.

  2. MULTI-EPOCH VERY LONG BASELINE ARRAY OBSERVATIONS OF THE COMPACT WIND-COLLISION REGION IN THE QUADRUPLE SYSTEM Cyg OB2 no. 5

    International Nuclear Information System (INIS)

    Dzib, Sergio A.; Rodríguez, Luis F.; Loinard, Laurent; Ortiz-León, Gisela N.; Araudo, Anabella T.; Mioduszewski, Amy J.

    2013-01-01

    We present multi-epoch Very Long Base Array observations of the compact wind-collision region in the Cyg OB2 no. 5 system. These observations confirm the arc-shaped morphology of the emission reported earlier. The total flux as a function of time is roughly constant when the source is 'on', but falls below the detection limit as the wind-collision region approaches periastron in its orbit around the contact binary at the center of the system. In addition, at one of the 'on' epochs, the flux drops to about a fifth of its average value. We suggest that this apparent variation could result from the inhomogeneity of the wind that hides part of the flux rather than from an intrinsic variation. We measured a trigonometrical parallax, for the most compact radio emission of 0.61 ± 0.22 mas, corresponding to a distance of 1.65 +0.96 –0.44 kpc, in agreement with recent trigonometrical parallaxes measured for objects in the Cygnus X complex. Using constraints on the total mass of the system and orbital parameters previously reported in the literature, we obtain two independent indirect measurements of the distance to the Cyg OB2 no. 5 system, both consistent with 1.3-1.4 kpc. Finally, we suggest that the companion star responsible for the wind interaction, yet undetected, is of spectral type between B0.5 and O8.

  3. Glucose metabolism and recycling by hepatocytes of OB/OB and ob/ob mice

    International Nuclear Information System (INIS)

    Lahtela, J.T.; Wals, P.A.; Katz, J.

    1990-01-01

    Hepatocytes were prepared from livers of ob/ob (obese diabetic) mice and their lean (OB/OB) siblings that had been fasted for 24 h. The hepatocytes were incubated with [U-14C, 2-3H]-, [U-14C, 3-3H]-, and [U-14C, 6-3H]glucose at concentrations from 20 to 120 mM. 14C was recovered mainly in CO2, glycogen, and lactate. Tritium was recovered in water and glycogen. The yield in labeled products from [2-3H]glucose ranged from two to three times that from [U-14C]glucose. The yields from [3-3H]- and [6-3H]glucose were similar, and 1.3-1.7 times that from [U-14C]glucose. At 40 mM, total utilization of glucose by obese mice was about twice that for lean mice, but there was little difference at 120 mM. The rate of recycling between glucose and glucose 6-phosphate was calculated. An equation to calculate the rate of recycling of glucose from the 2-3H/U-14C ratio in glycogen is derived in the APPENDIX. Our results show that (1) the utilization of glucose by hepatocytes from obese diabetic mice exceeds that of their lean controls, (2) the rate of glucose phosphorylation in both groups greatly exceeds glucose uptake and the rate of glycogen synthesis, (3) glucose phosphorylation represents a difference between a high glucokinase rate and hydrolysis of glucose 6-phosphate, and (4) recycling of glucose carbon between glucose 6-phosphate and pyruvate occurs within mouse hepatocytes

  4. Three cases of systemic amyloidosis successfully diagnosed by subcutaneous fat tissue biopsy of the hip

    Directory of Open Access Journals (Sweden)

    Arahata M

    2016-08-01

    Full Text Available Masahisa Arahata,1 Shigeru Shimadoi,1 Satosi Yamatani,1 Shin-ichi Hayashi,2 Shigeharu Miwa,2 Hidesaku Asakura,3 Shinji Nakao4 1Department of Internal Medicine, Nanto Municipal Hospital, Nanto, 2Department of Diagnostic Pathology, Graduate School of Medicine and Pharmaceutical Sciences, University of Toyama, Toyama, 3Department of Internal Medicine (III, 4Department of Cellular Transplantation Biology, Division of Cancer Medicine, Graduate School of Medical Science, Kanazawa University, Kanazawa, Japan Abstract: Fine-needle aspiration biopsy of the abdominal fat pad is considered to be a minimally invasive procedure for diagnosing systemic amyloidosis. However, this procedure is sometimes difficult and can be dangerous for elderly patients whose abdominal fat layer is thin because of malnutrition. In such cases, alternative diagnostic methods are required. We report three elderly patients with heart failure complicated by malnutrition. In all cases, electrocardiogram showed low voltage in the limb leads and a pseudoinfarct pattern in the chest leads, and echocardiography showed left ventricular wall thickening with granular sparkling appearance. These patients were suspected of having amyloid cardiomyopathy but could not undergo myocardial biopsies because of their poor conditions. After failed attempts at biopsy of the abdominal fat pad or the other organs, subcutaneous fat tissue biopsy over the hip led to the diagnosis of systemic amyloidosis with cardiomyopathy. The resultant diagnosis guided us to choose the appropriate treatment for the patients. This article illustrates that subcutaneous fat tissue biopsy of the hip could be a useful procedure for diagnosing systemic amyloidosis in elderly patients, particularly when a fat tissue biopsy of the abdomen is associated with a high risk of complications because of malnutrition. Keywords: systemic amyloidosis, amyloid cardiomyopathy, fine-needle aspiration biopsy, subcutaneous fat tissue, hip

  5. A New System for Neuronavigation and Stereotactic Biopsy ...

    African Journals Online (AJOL)

    This hybrid system comprises three main parts: main frame, monitoring system, and pantograph, which are connected to each other and to the operating table by particular attachments. For using this system, after performing CT SCAN or Magnetic Resonance Imaging (MRI) the axial view will be transferred to Liquid Cristal ...

  6. Robot-assisted biopsies in a high-field MRI system. First clinical results

    International Nuclear Information System (INIS)

    Schell, B.; Eichler, K.; Mack, M.G.; Mueller, C.; Kerl, J.M.; Beeres, M.; Thalhammer, A.; Vogl, T.J.; Zangos, S.; Czerny, C.

    2012-01-01

    Purpose: The purpose of this study was to examine the clinical use of MR-guided biopsies in patients with suspicious lesions using a new MR-compatible assistance system in a high-field MR system. Materials and Methods: Six patients with suspicious focal lesions in various anatomic regions underwent percutanous biopsy in a high-field MR system (1.5 T, Magnetom Espree, Siemens) using a new MR-compatible assistance system (Innomotion). The procedures were planned and guided using T1-weighted FLASH and TrueFISP sequences. A servopneumatic drive then moved the guiding arm automatically to the insertion point. An MRI compatible 15G biopsy system (Somatex) was introduced by a physician guided by the needle holder and multiple biopsies were performed using the coaxial technique. The feasibility, duration of the intervention and biopsy findings were analyzed. Results: The proposed new system allows accurate punctures in a high-field MR system. The assistance device did not interfere with the image quality, and guided the needle virtually exactly as planned. Histological examination could be conducted on every patient. The lesion was malignant in four cases, and an infectious etiology was diagnosed for the two remaining lesions. Regarding the differentiation of anatomical and pathological structures and position monitoring of the insertion needle, TrueFISP images are to be given preference. The average intervention time was 41 minutes. Lesions up to 15.4 cm beneath the skin surface were punctured. Conclusion: The proposed MR-guided assistance system can be successfully utilized in a high-field MR system for accurate punctures of even deep lesions in various anatomic regions. (orig.)

  7. Stormram 3: A Magnetic Resonance Imaging-Compatible Robotic System for Breast Biopsy

    NARCIS (Netherlands)

    Groenhuis, Vincent; Veltman, Jeroen; Siepel, Françoise Jeanette; Stramigioli, Stefano

    2017-01-01

    Stormram 3 is an MRI-compatible robotic system that can perform MR guided breast biopsies of suspicious lesions. The base of the robot measures 160x180x90 mm and it is actuated by five custom pneumatic linear stepper motors, driven by a valve manifold outside the Faraday cage of the MRI scanner. All

  8. Evolution of Robot-assisted ultrasound-guided breast biopsy systems

    Directory of Open Access Journals (Sweden)

    Mustafa Z. Mahmoud

    2018-01-01

    Full Text Available Robot-assisted ultrasound-guided breast biopsy combines ultrasound (US imaging with a robotic system for medical interventions. This study was designed to provide a literature review of a robotic US-guided breast biopsy system to delineate its efficacious impact on current medical practice. In addition, the strengths and limitations of this approach were also addressed. Articles published in the English language between 2000 and 2016 were appraised in this review. A wide range of systems that bind robotics with US imaging and guided breast biopsy were examined in this article. The fundamental safety and real-time imaging capabilities of US, together with the accuracy and maneuverability of robotic devices, is clearly an effective association with unmatched capabilities. Numerous experimental systems have obvious benefits over old-fashioned techniques, and the future of robot-assisted US-guided breast biopsy will be characterized by increasing levels of automation, and they hold tremendous possibility to impact doctor achievement, patient recovery, and clinical management.

  9. Manta A New BroadBand OBS

    Science.gov (United States)

    Hello, Y.; Yegikyan, M.; Charvis, P.; Philippe, O.

    2017-12-01

    Manta is a new BroadBand OBS developed at Geoazur and commercialized by Osean. The design is inspired by 3-years autonomy MUG-OBS a Multiparameter Ocean Bottom System which carry a lot of sort of sensor types. As Mug-OBS, Manta-OBS rated 6000m is designed to resist a trawling. All the components are non corrosive such polyethylene, titanium and buoyancy is ensured by syntactic foam. Equipped in standard version with a Trillium compact OBS Manta has an autonomy of 18 months, but can accept on its 4 input channels any kind of signal as low as from an hydrophone or larger from other type of a seismometer or accelerometer. Tri-axial geophones unit (2 Hz or 4.5 Hz ) can replace the seismometer and will expend the lifespan for the instrument. The seismometer is encapsulated in a central well established by four panels of the main structure to protect it from sea current convection and is decoupled from main chassis. An health bulletin is recoverable by acoustic any time to facilitate the installation and during a visit when instrument is deployed. Main parameters for acquisition can be changed by acoustics command from surface at any time. Once at the bottom, release for the main sensor installation is programmed on a timer but controlled by the tilt of the OBS. If the tilt is too important based on programmed limits, sensor will not released automatically, but this can be forced by acoustic command after returning the tilt informations to the boat operator. Manta is equipped with flash light and AIS system for easy location at recovery, and can also send it's position by Iridium satellite in case of an unexpected ascent such caused by a possible trawling if deployed in shallow water. Clock drift calculation is automatically made against GPS time signal once the OBS return at the surface. The recovery of the OBS is initiated by an acoustic command. These new features made Manta a very versatile instrument for monitoring earthquakes.

  10. Gels and gel-derived glasses in the Na2O-B2O3-SiO2 system. [containerless melting in space

    Science.gov (United States)

    Mukherjee, S. P.

    1982-01-01

    The containerless melting of high-purity multicomponent homogeneous gels and gel-monoliths offers a unique approach to making ultrapure multicomponent optical glasses in the reduced gravity environment of space. Procedures for preparing and characterizing gels and gel-derived glasses in the Na2O-B2O3-SiO2 system are described. Preparation is based on the polymerization reactions of alkoxysilane with trimethyl borate or boric acid and a suitable sodium compound. The chemistry of the gelling process is discussed in terms of process parameters and the gel compositions. The physicochemical nature of gels prepared by three different procedures were found to be significantly different. IR absorption spectra indicate finite differences in the molecular structures of the different gels. The melting of the gel powders and the transformation of porous gel-monoliths to transparent 'glass' without melting are described.

  11. Gels and gel-derived glasses in the system Na2O-B2O3-SiO2

    Science.gov (United States)

    Mukherjee, S. P.

    1983-01-01

    The containerless melting of high-purity multicomponent homogeneous gels and gel monoliths offers a unique approach to making ultrapure multicomponent optical glasses in the reduced gravity environment of space. Procedures for preparing and characterizing gels and gel-derived glasses in the system Na2O-B2O3-SiO2 are described. Preparation is based on the polymerization reactions of alkoxysilane with trimethyl borate or boric acid and a suitable sodium compound. The chemistry of the gelling process is discussed in terms of process parameters and the gel compositions. The physicochemical nature of gels prepared by three different procedures was found to be significantly different. Infrared absorption spectra indicate finite differences in the molecular structures of the different gels. The melting of the gel powders and the transformation of porous gel monoliths to transparent 'glass' without melting are described.

  12. Preliminary experience with interactive guided brain biopsies using a vertically opened 0.5-T MR system

    International Nuclear Information System (INIS)

    Schneider, J.P.; Dietrich, J.; Lieberenz, S.; Schmidt, F.; Sorge, O.; Trantakis, C.; Seifert, V.; Kellermann, S.; Schober, R.; Franke, P.

    1999-01-01

    The purpose of our study was to evaluate the feasibility and accuracy of brain biopsies performed within a vertically opened MR system. We worked with the interventional 0.5-T MR ''SIGNA SP'' (General Electric Medical Systems, Milwaukee, Wis.) with an integrated tracking device ''Flashpoint Position Encoder'' (Image Guided Technologies, USA). As a holding device for this instrument we constructed a special frame. The whole system allows an exact adjustment of an optimum biopsy direction and guidance of the biopsy in a non-stereotactic, interactive mode in near real-time. As biopsy tools we used MR-compatible aspiration and specially made side-cut needles (Daum, Germany; E-Z-EM, USA). We performed a prospective diagnostic brain biopsy study in 18 patients. Guidance of the needle was carried out using gradient-echo single-slice technique. The sample was taken after controlling the exact position of the needle tip on spin-echo images. In 12 cases an exact neuropathological diagnosis was possible. In 6 cases of negative biopsy (4 aspiration biopsies) the samples were not representative. Our results demonstrate the feasibility of interactive MR-guided minimally invasive brain biopsies in an open MR system. The best results were achieved using cut needles for biopsies of contrast-enhancing lesions visible on T1-weighted gradient-echo guidance sequence. (orig.)

  13. Value of Diffusion Tensor Imaging of Prostate Cancer: Comparison with Systemic Prostate Biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Seong Kuk; Kim, Dong Won; Ha, Dong Ho; Kwon, Hee Jin; Kang, Myong Jin; Choi, Sun Seob; Nam, Kyung Jin; Kim, Jung Il [Dong-A University, Medical Center, Busan (Korea, Republic of)

    2011-02-15

    This study was performed to evaluate the usefulness of diffusion tensor imaging (DTI) and to correlate systemic twelve biopsy in prostate cancer. Thirty-one patients with suspected prostate cancer underwent MR imaging. DTI was performed prior to a prostate biopsy. We prospectively calculated the apparent diffusion coefficient (ADC) and fractional anisotropy (FA) value in each corresponding biopsy site. Twenty-three of 31 patients had histopathologically proven adenocarcinoma. Among the 276 biopsy cores of 23 patients with prostate cancer, 109 cores showed positive results (39%). The ADC and FA value of positive cores were 1.31 {+-} 0.34x10-3 mm2/s and 0.68 {+-} 0.07, and those of the negative cores were 1.74 {+-} 0.45x10-3 mm2/s and 0.54 {+-} 0.09, respectively. Eight patients without carcinoma showed an ADC value of 1.83 {+-} 0.26x10-3 mm2/s and an FA value of 0.47 {+-} 0.07. The ADC and FA value of positive cores were significantly lower and higher than those of negative cores and cancer-free patients, respectively (p < 0.05). The ADC and FA values using DTI may provide useful diagnostic information in the differentiation of cancerous tissues, although there is overlap in some cases

  14. Liver biopsy

    Science.gov (United States)

    Biopsy - liver; Percutaneous biopsy ... the biopsy needle to be inserted into the liver. This is often done by using ultrasound. The ... the chance of damage to the lung or liver. The needle is removed quickly. Pressure will be ...

  15. Quality assurance procedure for a gamma guided stereotactic breast biopsy system.

    Science.gov (United States)

    Welch, Benjamin L; Brem, Rachel; Black, Rachel; Majewski, Stan

    2006-01-01

    A quality assurance procedure has been developed for a prototype gamma-ray guided stereotactic biopsy system. The system consists of a compact small-field-of-view gamma-ray camera mounted to the rotational arm of a Lorad stereotactic biopsy system. The small-field-of-view gamma-ray camera has been developed for clinical applications where mammographic X-ray localization is not possible. Marker sources that can be imaged with the gamma-camera have been designed and built for quality assurance testing and to provide a fiducial reference mark. An algorithm for determining the three dimensional location of a region of interest, such as a lesion, relative to the fiducial mark has been implemented into the software control of the camera. This system can be used to determine the three-dimensional location of a region of interest from a stereo pair of images and that information can be used to guide a biopsy needle to that site. Point source phantom tests performed with the system have demonstrated that the camera can be used to localize a point of interest to within 1 mm, which is satisfactory for its use in needle localization.

  16. [Musculoskeletal biopsies in an open 0.5-T-MR system].

    Science.gov (United States)

    Pretzsch, M; Scholz, R; Moche, M; Thomas, M; Tannapfel, A; von Salis-Soglio, G

    2005-01-01

    MR-guided interventions have been successful in different medical disciplines. The aim of this paper is to report our results with the application of MR-guided biopsies of musculoskeletal lesions using an open 0.5-T-MR scanner and further to discuss these results on the basis of the available literature. Between 1998 and 2003 30 patients (average age 44.1 years) underwent a total of 31 biopsies. The interventions were performed in an open 0.5-T MRI system using an active optical localization system as well as a navigation system. For the motion tracking we used T (1)-weighted real-time sequences with 0.25 pictures per second. For the sampling MR-compatible instruments were used that were specially developed for this purpose. The data of this retrospective investigation are based on the evaluation of the patient documents and the radiological findings. On the basis of the histological findings the technical success rate and the histological overall accuracy were determined. In 81 % of the biopsies the histological diagnosis was correct. In cases of suspected inflammation the histological accuracy was smaller (70 %). No differences were observed between skeletal and soft-tissue lesions. The technical success rate amounted to 77.5 %. No procedural or anesthesiological complications occurred. The mean operating time amounted to 65 min including the time for motion tracking. In cases of suspected lesions of the musculoskeletal system, the MR-guided biopsy represents a promising and safe procedure to get a histological diagnosis. In cases of sufficient size of the lesion sampling of a representative probe is possible. On account of the outstanding performance in soft-part contrasting, the sensitive structures surrounding the lesion can be saved. Substantial disadvantages of the procedure are the high costs for personal and material and the long operating time.

  17. The Mammotome biopsy system is an effective treatment strategy for breast abscess.

    Science.gov (United States)

    Wang, Keren; Ye, Yuqin; Sun, Guang; Xu, Zheli

    2013-01-01

    Although most breast abscesses can be treated with the current first-line treatment of antibiotics by needle aspiration, the therapeutic duration is lengthy and recurrences often occur. Therefore, we aimed to investigate the clinical efficacy of the Mammotome biopsy system (Johnson & Johnson Corp., New Brunswick, NJ) in a cohort of patients with breast abscesses. Forty lactating and 30 nonlactating breast abscess patients with unfavorable outcomes with antibiotic treatment and/or needle aspiration failure were recruited and treated with the Mammotome biopsy system. Skin inflammation of all patients disappeared within 6 days with no recurrence. The clinical outcomes in patients with an abscess size ≤ 3.5 cm was significantly better than those with an abscess size >3.5 cm (P = .025). The Mammotome biopsy system, an effective treatment strategy that is minimally invasive and less damaging, in combination with appropriate antibiotic therapy can be used safely as the first-line approach to breast abscess management. Copyright © 2013 Elsevier Inc. All rights reserved.

  18. Toward a real-time system for temporal enhanced ultrasound-guided prostate biopsy.

    Science.gov (United States)

    Azizi, Shekoofeh; Van Woudenberg, Nathan; Sojoudi, Samira; Li, Ming; Xu, Sheng; Abu Anas, Emran M; Yan, Pingkun; Tahmasebi, Amir; Kwak, Jin Tae; Turkbey, Baris; Choyke, Peter; Pinto, Peter; Wood, Bradford; Mousavi, Parvin; Abolmaesumi, Purang

    2018-03-27

    We have previously proposed temporal enhanced ultrasound (TeUS) as a new paradigm for tissue characterization. TeUS is based on analyzing a sequence of ultrasound data with deep learning and has been demonstrated to be successful for detection of cancer in ultrasound-guided prostate biopsy. Our aim is to enable the dissemination of this technology to the community for large-scale clinical validation. In this paper, we present a unified software framework demonstrating near-real-time analysis of ultrasound data stream using a deep learning solution. The system integrates ultrasound imaging hardware, visualization and a deep learning back-end to build an accessible, flexible and robust platform. A client-server approach is used in order to run computationally expensive algorithms in parallel. We demonstrate the efficacy of the framework using two applications as case studies. First, we show that prostate cancer detection using near-real-time analysis of RF and B-mode TeUS data and deep learning is feasible. Second, we present real-time segmentation of ultrasound prostate data using an integrated deep learning solution. The system is evaluated for cancer detection accuracy on ultrasound data obtained from a large clinical study with 255 biopsy cores from 157 subjects. It is further assessed with an independent dataset with 21 biopsy targets from six subjects. In the first study, we achieve area under the curve, sensitivity, specificity and accuracy of 0.94, 0.77, 0.94 and 0.92, respectively, for the detection of prostate cancer. In the second study, we achieve an AUC of 0.85. Our results suggest that TeUS-guided biopsy can be potentially effective for the detection of prostate cancer.

  19. Prostate biopsy

    Science.gov (United States)

    ... give the cells a grade called a Gleason score . This helps predict how fast the cancer will ... TRUS); Stereotactic transperineal prostate biopsy (STPB) Images Male reproductive anatomy References Babayan RK, Katz MH. Biopsy prophylaxis, ...

  20. Kidney biopsy

    Science.gov (United States)

    ... the kidney (in rare cases, may require a blood transfusion) Bleeding into the muscle, which might cause soreness Infection (small risk) Alternative Names Renal biopsy; Biopsy - kidney Images Kidney anatomy ...

  1. In-Bore MR-Guided Biopsy Systems and Utility of PI-RADS

    NARCIS (Netherlands)

    Futterer, J.J.; Moche, M.; Busse, H.; Yakar, D.

    2016-01-01

    A diagnostic dilemma exists in cases wherein a patient with clinical suspicion for prostate cancer has a negative transrectal ultrasound-guided biopsy session. Although transrectal ultrasound-guided biopsy is the standard of care, a paradigm shift is being observed. In biopsy-naive patients and

  2. Genetically obese (ob/ob) mice are resistant to the lethal effects of thioacetamide hepatotoxicity

    International Nuclear Information System (INIS)

    Won, Young-Suk; Song, Ji-Won; Lim, Jong-Hwan; Lee, Mee-Young; Moon, Og-Sung; Kim, Hyoung-Chin; Son, Hwa-Young; Kwon, Hyo-Jung

    2016-01-01

    Obesity increases the risk of chronic liver diseases, including viral hepatitis, alcohol-induced liver disease, and non-alcoholic steatohepatitis. In this study, we investigated the effects of obesity in acute hepatic failure using a murine model of thioacetamide (TA)-induced liver injury. Genetically obese ob/ob mice, together with non-obese ob/+ littermates, were subjected to a single intraperitoneal injection of TA, and examined for signs of hepatic injury. ob/ob mice showed a significantly higher survival rate, lower levels of serum alanine aminotransferase and aspartate aminotransferase, and less hepatic necrosis and apoptosis, compared with ob/+ mice. In addition, ob/ob mice exhibited significantly lower levels of malondialdehyde and significantly higher levels of glutathione and antioxidant enzyme activities compared with their ob/+ counterparts. Bioactivation analyses revealed reduced plasma clearance of TA and covalent binding of [ 14 C]TA to liver macromolecules in ob/ob mice. Together, these data demonstrate that genetically obese mice are resistant to TA-induced acute liver injury through diminished bioactivation of TA and antioxidant effects. - Highlights: • ob/ob mice are resistant to lethal doses of thioacetamide, compared to ob/+ mice. • ob/ob mice show reduced oxidative stress and enhanced antioxidant enzyme activity. • ob/ob mice exhibit diminished bioactivation of thioacetamide.

  3. Genetically obese (ob/ob) mice are resistant to the lethal effects of thioacetamide hepatotoxicity

    Energy Technology Data Exchange (ETDEWEB)

    Won, Young-Suk [Laboratory Animal Resource Center, Korea Research Institute of Bioscience and Biotechnology, Chungbuk (Korea, Republic of); Song, Ji-Won [Department of Veterinary Pathology, College of Veterinary Medicine, Chungnam National University, Daejeon (Korea, Republic of); Lim, Jong-Hwan [Huons Research Center, Gyonggido (Korea, Republic of); Lee, Mee-Young [Herbal Medicine Formulation Research Group, Korea Institute of Oriental Medicine, Daejeon (Korea, Republic of); Moon, Og-Sung; Kim, Hyoung-Chin [Laboratory Animal Resource Center, Korea Research Institute of Bioscience and Biotechnology, Chungbuk (Korea, Republic of); Son, Hwa-Young [Department of Veterinary Pathology, College of Veterinary Medicine, Chungnam National University, Daejeon (Korea, Republic of); Kwon, Hyo-Jung, E-mail: hyojung@cnu.ac.kr [Department of Veterinary Pathology, College of Veterinary Medicine, Chungnam National University, Daejeon (Korea, Republic of)

    2016-01-15

    Obesity increases the risk of chronic liver diseases, including viral hepatitis, alcohol-induced liver disease, and non-alcoholic steatohepatitis. In this study, we investigated the effects of obesity in acute hepatic failure using a murine model of thioacetamide (TA)-induced liver injury. Genetically obese ob/ob mice, together with non-obese ob/+ littermates, were subjected to a single intraperitoneal injection of TA, and examined for signs of hepatic injury. ob/ob mice showed a significantly higher survival rate, lower levels of serum alanine aminotransferase and aspartate aminotransferase, and less hepatic necrosis and apoptosis, compared with ob/+ mice. In addition, ob/ob mice exhibited significantly lower levels of malondialdehyde and significantly higher levels of glutathione and antioxidant enzyme activities compared with their ob/+ counterparts. Bioactivation analyses revealed reduced plasma clearance of TA and covalent binding of [{sup 14}C]TA to liver macromolecules in ob/ob mice. Together, these data demonstrate that genetically obese mice are resistant to TA-induced acute liver injury through diminished bioactivation of TA and antioxidant effects. - Highlights: • ob/ob mice are resistant to lethal doses of thioacetamide, compared to ob/+ mice. • ob/ob mice show reduced oxidative stress and enhanced antioxidant enzyme activity. • ob/ob mice exhibit diminished bioactivation of thioacetamide.

  4. Influence able and Avoidable Risk Factors for Systemic Air Embolism due to Percutaneous CT-Guided Lung Biopsy: Patient Positioning and Coaxial Biopsy Technique-Case Report, Systematic Literature Review, and a Technical Note

    International Nuclear Information System (INIS)

    Rott, G.; Boecker, F.

    2014-01-01

    Following the first case of a systemic air embolism due to percutaneous CT-guided lung biopsy in our clinic we analysed the literature regarding this matter in view of influence able or avoidable risk factors. A systematic review of literature reporting cases of systemic air embolism due to CT-guided lung biopsy was performed to find out whether prone positioning might be a risk factor regarding this issue. In addition, a technical note concerning coaxial biopsy practice is presented. Prone position seems to have relevance for the development and/or clinical manifestation of air embolism due to CT-guided lung biopsy and should be considered a risk factor, at least as far as lesions in the lower parts of the lung are concerned. Biopsies of small or cavitary lesions in coaxial technique should be performed using a hemo static valve.

  5. The current content of artificial radionuclides in the water of the Tobol-Irtysh river system (from the mouth of the Iset River to the confluence with the Ob River)

    Energy Technology Data Exchange (ETDEWEB)

    Nikitin, Alexander I. [SI RPA ' Typhoon' of the Roshydromet, 82, Lenin avenue, Obninsk, Kaluga region 249038 (Russian Federation)]. E-mail: nikitin@typhoon.obninsk.ru; Chumichev, Vladimir B. [SI RPA ' Typhoon' of the Roshydromet, 82, Lenin avenue, Obninsk, Kaluga region 249038 (Russian Federation); Valetova, Nailia K. [SI RPA ' Typhoon' of the Roshydromet, 82, Lenin avenue, Obninsk, Kaluga region 249038 (Russian Federation); Katrich, Ivan Yu. [SI RPA ' Typhoon' of the Roshydromet, 82, Lenin avenue, Obninsk, Kaluga region 249038 (Russian Federation); Kabanov, Alexander I. [SI RPA ' Typhoon' of the Roshydromet, 82, Lenin avenue, Obninsk, Kaluga region 249038 (Russian Federation); Dunaev, Gennady E. [SI RPA ' Typhoon' of the Roshydromet, 82, Lenin avenue, Obninsk, Kaluga region 249038 (Russian Federation); Shkuro, Valentina N. [SI RPA ' Typhoon' of the Roshydromet, 82, Lenin avenue, Obninsk, Kaluga region 249038 (Russian Federation); Rodin, Victor M. [Tobolsk Biological Station of RAS, 15, Voikov street, Tobolsk, Tyumen region 626150 (Russian Federation); Mironenko, Alexander N. [Tobolsk Biological Station of RAS, 15, Voikov street, Tobolsk, Tyumen region 626150 (Russian Federation); Kireeva, Elena V. [Tobolsk Biological Station of RAS, 15, Voikov street, Tobolsk, Tyumen region 626150 (Russian Federation)

    2007-07-15

    Data on content of {sup 90}Sr, {sup 137}Cs, {sup 239,240}Pu and {sup 3}H in water of the Tobol-Irtysh part of the Techa-Iset-Tobol-Irtysh-Ob river system (through which the 'Mayak' PA radioactive wastes are transported) are presented and discussed. The data were received in 2004-2005 under the ISTC project on radioecological monitoring of the Tobol and Irtysh rivers. Monthly observations of {sup 137}Cs, {sup 90}Sr and {sup 3}H content in water in the area of the Tobol and Irtysh confluence have been conducted starting from May 2004. To obtain information on the investigated river system as a whole, the radioecological survey of the Tobol and Irtysh rivers at the section from the mouth of the Iset River to the confluence with the Ob River was carried out in 2004. It is shown that the impact of 'Mayak' PA waste transport by {sup 90}Sr is distinctly traced as far as the area of the Irtysh and Ob confluence.

  6. The current content of artificial radionuclides in the water of the Tobol-Irtysh river system (from the mouth of the Iset River to the confluence with the Ob River)

    International Nuclear Information System (INIS)

    Nikitin, Alexander I.; Chumichev, Vladimir B.; Valetova, Nailia K.; Katrich, Ivan Yu.; Kabanov, Alexander I.; Dunaev, Gennady E.; Shkuro, Valentina N.; Rodin, Victor M.; Mironenko, Alexander N.; Kireeva, Elena V.

    2007-01-01

    Data on content of 90 Sr, 137 Cs, 239,240 Pu and 3 H in water of the Tobol-Irtysh part of the Techa-Iset-Tobol-Irtysh-Ob river system (through which the 'Mayak' PA radioactive wastes are transported) are presented and discussed. The data were received in 2004-2005 under the ISTC project on radioecological monitoring of the Tobol and Irtysh rivers. Monthly observations of 137 Cs, 90 Sr and 3 H content in water in the area of the Tobol and Irtysh confluence have been conducted starting from May 2004. To obtain information on the investigated river system as a whole, the radioecological survey of the Tobol and Irtysh rivers at the section from the mouth of the Iset River to the confluence with the Ob River was carried out in 2004. It is shown that the impact of 'Mayak' PA waste transport by 90 Sr is distinctly traced as far as the area of the Irtysh and Ob confluence

  7. Cold knife cone biopsy

    Science.gov (United States)

    ... biopsy; Pap smear - cone biopsy; HPV - cone biopsy; Human papilloma virus - cone biopsy; Cervix - cone biopsy; Colposcopy - cone biopsy Images Female reproductive anatomy Cold cone biopsy Cold cone removal References Baggish ...

  8. Analysis of 62 cases with stereotaxic breast biopsy with a prone table system: emphasis on lesions with microcalcificatios

    International Nuclear Information System (INIS)

    Chung, Il Gyu; Choe, Yeon Hyeon; Han, Boo Kyung; Byun, Hong Sik; Choo, In Wook

    1999-01-01

    To evaluate the efficacy of stereotaxic breast core biopsy using a prone table system, and the effects of operator experience, lesion characteristics and number of samples on biopsy results in cases involving nonpalpable breast lesions. We performed stereotaxic core biopsies of 62 nonpalpable mammographic lesions in 61 patients. Subsequent surgical excision was performed in 11 cases with microcalcifications and one case with a mass. We equally divided patients with microcalcifications into two groups (early and late periods) and analyzed the mammographic findings. Correlation of the pathologic results of core biopsy with those of surgical excision were investigated. In two patients, stereotaxic biopsy was impossible due to poor visibility of microcalcifications and thinness of the compressed breast. In 59 patients, core biopsy was successfully performed and specimens were adequate for pathologic examination. The average number of microcalcifications seen on specimen mammography in the two groups was 1.8(range : 0x8) and 2.5(range : 0x4) respectively. In patients from whom less than five and five or more samples were taken, the average number of microcalcifications seen on specimen mammography was 1.5(range : 0x6) and 2.6(range : 0x8), respectively, throughout the whole period. The pathologic findings were fibrocystic change in 50 cases, fibroadenoma in four, ductal carcinoma in situ in four, invasive ductal carcinoma in one, and atypical ductal hyperplasia in one. The agreement rate of pathologic results between core biopsy and surgical excision was 83%(10/12) for malignancy and 75% for histology. In three cases with disagreement between core and surgical pathologic results, the sampling number was small (3x 4 times) and in two of the three cases, microcalcifications were not visible on mammography operator experience and sampling numbers larger than five results in an increased number of microcalcifications in specimens and more reliable core biopsy

  9. Analysis of 62 cases with stereotaxic breast biopsy with a prone table system: emphasis on lesions with microcalcificatios

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Il Gyu; Choe, Yeon Hyeon; Han, Boo Kyung; Byun, Hong Sik; Choo, In Wook [Sungkyunkwan University College of Medicine, Seoul (Korea, Republic of)

    1999-02-01

    To evaluate the efficacy of stereotaxic breast core biopsy using a prone table system, and the effects of operator experience, lesion characteristics and number of samples on biopsy results in cases involving nonpalpable breast lesions. We performed stereotaxic core biopsies of 62 nonpalpable mammographic lesions in 61 patients. Subsequent surgical excision was performed in 11 cases with microcalcifications and one case with a mass. We equally divided patients with microcalcifications into two groups (early and late periods) and analyzed the mammographic findings. Correlation of the pathologic results of core biopsy with those of surgical excision were investigated. In two patients, stereotaxic biopsy was impossible due to poor visibility of microcalcifications and thinness of the compressed breast. In 59 patients, core biopsy was successfully performed and specimens were adequate for pathologic examination. The average number of microcalcifications seen on specimen mammography in the two groups was 1.8(range : 0x8) and 2.5(range : 0x4) respectively. In patients from whom less than five and five or more samples were taken, the average number of microcalcifications seen on specimen mammography was 1.5(range : 0x6) and 2.6(range : 0x8), respectively, throughout the whole period. The pathologic findings were fibrocystic change in 50 cases, fibroadenoma in four, ductal carcinoma in situ in four, invasive ductal carcinoma in one, and atypical ductal hyperplasia in one. The agreement rate of pathologic results between core biopsy and surgical excision was 83%(10/12) for malignancy and 75% for histology. In three cases with disagreement between core and surgical pathologic results, the sampling number was small (3x 4 times) and in two of the three cases, microcalcifications were not visible on mammography operator experience and sampling numbers larger than five results in an increased number of microcalcifications in specimens and more reliable core biopsy.

  10. Promise(s of mesenchymal stem cells as an in vitro model system to depict pre-diabetic/diabetic milieu in WNIN/GR-Ob mutant rats.

    Directory of Open Access Journals (Sweden)

    Soundarya L Madhira

    Full Text Available BACKGROUND: Development of model systems have helped to a large extent, in bridging gap to understand the mechanism(s of disease including diabetes. Interestingly, WNIN/GR-Ob rats (Mutants, established at National Centre for Laboratory Animals (NCLAS of National Institute of Nutrition (NIN, form a suitable model system to study obesity with Type 2 diabetes (T2D demonstrating several secondary complications (cataract, cardiovascular complications, infertility, nephropathy etc. The present study has been carried out to explore the potent application(s of multipotent stem cells such as bone marrow mesenchymal stem cells (BM-MSCs, to portray features of pre-diabetic/T2D vis-à-vis featuring obesity, with impaired glucose tolerance (IGT, hyperinsulinemia (HI and insulin resistance (IR seen with Mutant rats akin to human situation. METHODOLOGY/PRINCIPAL FINDINGS: Primary cultures of BM-MSCs (third passage from Mutants, its lean littermate (Lean and parental control (Control were characterized for: proliferation markers, disease memory to mark obesity/T2D/HI/IR which included phased gene expression studies for adipogenic/pancreatic lineages, inflammatory markers and differentiation ability to form mature adipocytes/Insulin-like cellular aggregates (ILCAs. The data showed that BM-MSCs from Mutant demonstrated a state of disease memory, depicted by an upregulated expression of inflammatory markers (IL-6, TNFα; increased stem cell recruitment (Oct-4, Sox-2 and proliferation rates (CD90+/CD29+, PDA, 'S' phase of cell cycle by FACS and BrdU incorporation; accelerated preadipocyte induction (Dact-1, PPARγ2 with a quantitative increase in mature adipocyte formation (Leptin; ILCAs, which were non-responsive to high glucose did confer the Obese/T2D memory in Mutants. Further, these observations were in compliance with the anthropometric data. CONCLUSIONS: Given the ease of accessibility and availability of MSCs, the present study form the basis to report for

  11. An automated robot arm system for small animal tissue biopsy under dual-image modality

    International Nuclear Information System (INIS)

    Huang, Y.H.; Wu, T.H.; Lin, M.H.; Yang, C.C.; Guo, W.Y.; Wang, Z.J.; Chen, C.L.; Lee, J.S.

    2006-01-01

    The ability to non-invasively monitor cell biology in vivo is one of the most important goals of molecular imaging. Imaging procedures could be inter-subject performed repeatedly at different investigating stages; thereby need not sacrifice small animals during the entire study period. Thus, the ultimate goal of this study was to design a stereotactic image-guided system for small animals and integrated it with an automatic robot arm for in vivo tissue biopsy analysis. The system was composed of three main parts, including one small animal stereotactic frame, one imaging-fusion software and an automatic robot arm system. The system has been thoroughly evaluated with three components; the robot position accuracy was 0.05±0.02 mm, the image registration accuracy was 0.37±0.18 mm and the system integration was satisfactorily within 1.20±0.39 mm of error. From these results, the system demonstrated sufficient accuracy to guide the micro-injector from the planned delivery routes into practice. The entire system accuracy was limited by the image fusion and orientation procedures, due to its nature of the blurred PET imaging obtained from the small objects. The primary improvement is to acquire as higher resolution as possible the fused imaging for localizing the targets in the future

  12. Metabolic and hepatic effects of liraglutide, obeticholic acid and elafibranor in diet-induced obese mouse models of biopsy-confirmed nonalcoholic steatohepatitis

    Science.gov (United States)

    Tølbøl, Kirstine S; Kristiansen, Maria NB; Hansen, Henrik H; Veidal, Sanne S; Rigbolt, Kristoffer TG; Gillum, Matthew P; Jelsing, Jacob; Vrang, Niels; Feigh, Michael

    2018-01-01

    AIM To evaluate the pharmacodynamics of compounds in clinical development for nonalcoholic steatohepatitis (NASH) in obese mouse models of biopsy-confirmed NASH. METHODS Male wild-type C57BL/6J mice (DIO-NASH) and Lepob/ob (ob/ob-NASH) mice were fed a diet high in trans-fat (40%), fructose (20%) and cholesterol (2%) for 30 and 21 wk, respectively. Prior to treatment, all mice underwent liver biopsy for confirmation and stratification of liver steatosis and fibrosis, using the nonalcoholic fatty liver disease activity score (NAS) and fibrosis staging system. The mice were kept on the diet and received vehicle, liraglutide (0.2 mg/kg, SC, BID), obeticholic acid (OCA, 30 mg/kg PO, QD), or elafibranor (30 mg/kg PO, QD) for eight weeks. Within-subject comparisons were performed on changes in steatosis, inflammation, ballooning degeneration, and fibrosis scores. In addition, compound effects were evaluated by quantitative liver histology, including percent fractional area of liver fat, galectin-3, and collagen 1a1. RESULTS Liraglutide and elafibranor, but not OCA, reduced body weight in both models. Liraglutide improved steatosis scores in DIO-NASH mice only. Elafibranor and OCA reduced histopathological scores of hepatic steatosis and inflammation in both models, but only elafibranor reduced fibrosis severity. Liraglutide and OCA reduced total liver fat, collagen 1a1, and galectin-3 content, driven by significant reductions in liver weight. The individual drug effects on NASH histological endpoints were supported by global gene expression (RNA sequencing) and liver lipid biochemistry. CONCLUSION DIO-NASH and ob/ob-NASH mouse models show distinct treatment effects of liraglutide, OCA, and elafibranor, being in general agreement with corresponding findings in clinical trials for NASH. The present data therefore further supports the clinical translatability and utility of DIO-NASH and ob/ob-NASH mouse models of NASH for probing the therapeutic efficacy of compounds in

  13. Combined Fluoroscopy- and CT-Guided Transthoracic Needle Biopsy Using a C-Arm Cone-Beam CT System: Comparison with Fluoroscopy-Guided Biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Cheung, Joo Yeon; Kim, Yoo Kyung; Shim, Sung Shine; Lim, Soo Mee [School of Medicine, Ewha Womans University, Seoul (Korea, Republic of)

    2011-02-15

    The aim of this study was to evaluate the usefulness of combined fluoroscopy- and CT-guided transthoracic needle biopsy (FC-TNB) using a cone beam CT system in comparison to fluoroscopy-guided TNB (F-TNB). We retrospectively evaluated 74 FC-TNB cases (group A) and 97 F-TNB cases (group B) to compare their respective diagnostic accuracies according to the size and depth of the lesion, as well as complications, procedure time, and radiation dose. The sensitivity for malignancy and diagnostic accuracy for small (< 30 mm in size) and deep ({>=} 50 mm in depth) lesions were higher in group A (91% and 94%, 92% and 94%) than in group B (73% and 81%, 84% and 88%), however not statistically significant (p > 0.05). Concerning lesions {>=} 30 mm in size and < 50 mm in depth, both groups displayed similar results (group A, 91% and 92%, 80% and 87%: group B, 90% and 92%, 86% and 90%). Pneumothorax occurred 26% of the time in group A and 14% for group B. The mean procedure time and patient skin dose were significantly higher in group A (13.6 {+-} 4.0 minutes, 157.1 {+-} 76.5 mGy) than in group B (9.0 {+-} 3.5 minutes, 21.9 {+-} 15.2 mGy) (p < 0.05). Combined fluoroscopy- and CT-guided TNB allows the biopsy of small (< 30 mm) and deep lesions ({>=} 50 mm) with high diagnostic accuracy and short procedure times, whereas F-TNB is still a useful method for large and superficial lesions with a low radiation dose

  14. En bloc excision of nonpalpable breast lesions using the advanced breast biopsy instrumentation system: an alternative to needle guided surgery?

    International Nuclear Information System (INIS)

    Lifrange, E.; Colin, C.; Dondelinger, R.F.; Fridman, V.

    2001-01-01

    This study was prospectively conducted to evaluate the clinical potential of the advanced breast biopsy instrumentation (ABBI) system as an alternative to needle localization and open surgery in the management of nonpalpable breast lesions (NPBL). One hundred and eighty-six consecutive patients were referred for management of NPBL. Thirty-six underwent an ABBI procedure, offered as a first step before possible surgery for lesions which would in any case have required complete excision. The 18 patients with a malignant ABBI biopsy underwent re-excision of the biopsy site and axillary dissection was carried out in cases of infiltrating carcinoma. The other 150 patients underwent image-guided needle biopsy. Following these procedures, 60/150 (40 %) patients underwent needle-guided surgery. Finally, 96/186 (51 %) patients required complete excision. A total of 43 benign lesions and 53 carcinomas were confirmed. Thirty-six out of 96 (38 %) excisions were obtained with the ABBI system; 17/43 (40 %) benign lesions and 11/53 (21 %) carcinomas were completely removed with the ABBI system. Out of 9 malignant specimens with a pathological size less than 10 mm, 5/9 (55 %) had tumor-free margins and in 8/9 (89 %) no residual disease was found at re-excision. The preliminary results of this study suggest that, in selected cases, en bloc excision using the ABBI procedure could be an alternative to conventional surgery. (orig.)

  15. Endoscopic trans-nasal approach for biopsy of orbital tumors using image-guided neuro-navigation system

    International Nuclear Information System (INIS)

    Sieskiewicz, A.; Mariak, Z.; Rogowski, M.; Lyson, T.

    2008-01-01

    Histopathological diagnosis of intraorbital tumors is of crucial value for planning further therapy. The aim of the study was to explore clinical utility of image-guided endoscopy for biopsy of orbital tumors. Trans-nasal endoscopic biopsy of intraorbital mass lesions was performed in 6 patients using a neuro-navigation system (Medtronic Stealth Station Treon plus). The CT and MRI 1 mm slice images were fused by the system in order to visualise both bony and soft tissue structures. The anatomic fiducial registration protocol was used during the procedure. All lesions were precisely localised and the biopsies could be taken from the representative part of the pathological mass. None of the patients developed aggravation of ocular symptoms after the procedure. The operative corridor as well as the size of orbital wall fenestration could be limited to a minimum. The accuracy of neuro-navigation remained high and stable during the entire procedure. The image-guided neuro-navigation system facilitated endoscopic localisation and biopsy of intraorbital tumors and contributed to the reduction of surgical trauma during the procedure. The technique was particularly useful in small, medially located, retrobulbar tumors and in unclear situations when the structure of the lesion resembled surrounding intraorbital tissue. (author)

  16. The usefulness of the transrectal ultrasonography in the diagnosis of the prostate cancer : comparison with systemic sextant biopsy

    International Nuclear Information System (INIS)

    Moon, Min Hoan; Seong, Chang Kyu; Jeong, Jun Yong; Choi, Huck Jae; Sim, Jung Suk; Kim, Seung Hyup

    2001-01-01

    To retrospectively compared the usefulness of the transrectal ultrasonography LEAVE A SPACE(TRUS) and systemic sextant biopsy in the diagnosis of prostate cancer. A total of 84 patients with clinical and laboratory findings suggestive of prostate cancer underwent TRUS and systemic sextant biopsy. Nine patients with diffuse prostatic lesion had been excluded from the list. Following sonographic evaluation, additional targeted biopsy for the focal lesion was performed in 14 patients. A total of 464 biopsy specimens were obtained and retrospectively compared with the sonographic findings. For cancer, the sensitivity, specificity and false-positive rate of TRUS were 48%, 97% and 53%, respectively. The hypoechoic nodules seen in prostate cancer were more commonly located in the outer half of the peripheral zone of the prostate, while most BPH lesions were located in the inner half of this zone. Between prostate cancer and BPH there was statistically significant difference in the location of hypoechoic nodules revealed by TRUS (p=0.01). The location of the hypoechoic nodules provides useful information for differentiating between BPH nodules and malignant prostatic nodules and may reduce the false-positive rate of TRUS in the diagnosis of prostate cancer

  17. Abdominal fat pad excisional biopsy for the diagnosis and typing of systemic amyloidosis.

    Science.gov (United States)

    Garcia, Yessica; Collins, A Bernard; Stone, James R

    2018-02-01

    In the past, the diagnosis and typing of amyloidosis often required an invasive biopsy of an internal organ, such as the heart or kidneys. Abdominal fat pad excisional biopsy (FPEB) offers a less invasive approach, but the sensitivity of this technique has been unclear. To determine the sensitivity of FPEB for immunoglobulin light chain (AL) and transthyretin (ATTR) amyloidosis, we performed a retrospective clinicopathologic analysis of 97 patients who had undergone FPEB, of which 16 were positive for amyloid. The most significant pretest feature predicting a positive FPEB was a serum free light chain κ/λ ratio less than .5, and in this group of patients the probability of a positive biopsy was dependent on the size of the biopsy (P=.004). In FPEBs, the amyloid was present in multiple distinct patterns: pericellular, septal, medium-sized vessel, small vessel, and nodular. For patients with AL amyloidosis for which direct typing was attempted using the FPEB tissue, the amyloid was successfully typed in the FPEB in 90% of cases. The overall sensitivity of FPEB was 79% for AL amyloidosis and 12% for ATTR amyloidosis (P=.0003). In patients with AL amyloidosis, the sensitivity of FPEB was dependent on biopsy size, with small biopsies (≤700 mm 3 ) having a sensitivity of ~50%, and large biopsies (>700 mm 3 ) having a sensitivity of ~100%. This study demonstrates that FPEB has high sensitivity for AL amyloidosis, and can be routinely used to type the amyloid. However, FPEB has low sensitivity for ATTR amyloidosis in our patient population. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Percutaneous excisional biopsy of clinically benign breast lesions with vacuum-assisted system: comparison of three devices.

    Science.gov (United States)

    Wang, Zhi Li; Liu, Gang; Huang, Yan; Wan, Wen Bo; Li, Jun Lai

    2012-04-01

    The aim of this study was to compare three devices in percutaneous excisional biopsy of clinically benign breast lesions in terms of complete excision rate, duration of procedure and complications. In a retrospective study from March 2005 to May 2009, 983 lesions underwent ultrasound-guided excisional biopsy with three vacuum-assisted systems, respectively. The lesions were category 3 lesions as determined by ultrasound imaging according to Breast Imaging Reporting and Data System (BI-RADS) (n=951) or had been confirmed as benign by a previous core needle biopsy (n=32). The completely excision rate, duration of procedure and complications (hematoma, pain and ecchymosis) were recorded. 99.7% (980/983) lesions were demonstrated to be benign by pathology after percutaneous excisional biopsy. The overall complete excision rate was 94.8% (932/983). In lesions whose largest diameter equal to or larger than 1.5cm, the complete excision rates of EnCor(®) group (97.8%, 348/356) and Mammotome(®) group (97.2%, 139/143) were significantly higher than that of Vacora(®) group (91.9%, 445/484) (P<0.05). The EnCor(®) group (6.6±6.5min) had a significant less duration than Mammotome(®) (10.6±9.3min) and Vacora(®) group (25.6±23.3min) (P<0.05). Hematoma occurred more in EnCor(®) group and Mammotome(®) group than in Vacora(®) group (P<0.05). All these three vacuum-assisted systems are highly successful for excisional biopsy of benign breast lesions. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  19. Obs4MIPS: Satellite Observations for Model Evaluation

    Science.gov (United States)

    Ferraro, R.; Waliser, D. E.; Gleckler, P. J.

    2017-12-01

    This poster will review the current status of the obs4MIPs project, whose purpose is to provide a limited collection of well-established and documented datasets for comparison with Earth system models (https://www.earthsystemcog.org/projects/obs4mips/). These datasets have been reformatted to correspond with the CMIP5 model output requirements, and include technical documentation specifically targeted for their use in model output evaluation. The project holdings now exceed 120 datasets with observations that directly correspond to CMIP5 model output variables, with new additions in response to the CMIP6 experiments. With the growth in climate model output data volume, it is increasing more difficult to bring the model output and the observations together to do evaluations. The positioning of the obs4MIPs datasets within the Earth System Grid Federation (ESGF) allows for the use of currently available and planned online tools within the ESGF to perform analysis using model output and observational datasets without necessarily downloading everything to a local workstation. This past year, obs4MIPs has updated its submission guidelines to closely align with changes in the CMIP6 experiments, and is implementing additional indicators and ancillary data to allow users to more easily determine the efficacy of an obs4MIPs dataset for specific evaluation purposes. This poster will present the new guidelines and indicators, and update the list of current obs4MIPs holdings and their connection to the ESGF evaluation and analysis tools currently available, and being developed for the CMIP6 experiments.

  20. Zinc metabolism in genetically obese (ob/ob) mice

    International Nuclear Information System (INIS)

    Kennedy, M.L.; Failla, M.L.

    1987-01-01

    Recent reports indicate that the concentrations and total amounts of several essential trace metals in various tissues of genetically obese rodents differ markedly from those in lean controls. In the present studies the absorption, retention and tissue distribution of zinc and constitutive levels of zinc-metallothionein (Zn-MT) in selected tissues were compared in obese (ob/ob) and lean (+/?) C57BL/6J mice. When 5-, 10- and 22-wk-old mice were administered 1.2 mumol 65 Zn by stomach tube the apparent absorption of 65 Zn by obese mice was 1.5, 2.2 and 3.9 times higher, respectively, than that in age-matched lean mice. Retention of orally administered 65 Zn after 96 h was also substantially higher in obese mice than in lean mice. To assess the possible influences of hyperphagia and intestinal hypertrophy on the enhanced apparent absorption of 65 Zn by obese mice food intake by an additional group of obese mice was restricted to that of age-matched lean controls. When actual absorption of zinc was determined according to the method of Heth and Hoekstra, groups of ad libitum--fed obese, pair-fed obese and lean mice absorbed 38, 32 and 18% of administered 65 Zn, respectively. In contrast, the rate of 65 Zn excretion 2-6 d after oral or subcutaneous administration of the metal was similar for obese and lean mice. Unrestricted and pair-fed obese mice had significantly lower percentages of carcass 65 Zn present in skin, muscle plus bone, spleen and testes and higher percentages present in liver, small intestine and adipose tissue than lean mice

  1. First use of a truly-hybrid x-ray/MR imaging system for guidance of brain biopsy

    International Nuclear Information System (INIS)

    Fahrig, R.; Daniel, B.L.; Butts, K.; Pelc, N.J.; Heit, G.; Wen, Z.

    2003-01-01

    The use of a new hybrid imaging system for guidance of a brain biopsy is described. The system combines the strengths of MRI (soft-tissue contrast, arbitrary plane selection) with those of x-ray fluoroscopy (high-resolution real-time projection images, clear portrayal of bony structures) and allows switching between the imaging modalities without moving the patient. The biopsy was carried out using x-ray guidance for direction of the needle through the foramen ovale and MR guidance to target the soft-tissue lesion. Appropriate samples were acquired. The system could be particularly effective for guidance of those cases where motion, swelling, resection and other intra-operative anatomical changes cannot be accounted for using traditional stereotactic-based imaging approaches. (author)

  2. Combination of prostate imaging reporting and data system (PI-RADS) score and prostate-specific antigen (PSA) density predicts biopsy outcome in prostate biopsy naïve patients.

    Science.gov (United States)

    Washino, Satoshi; Okochi, Tomohisa; Saito, Kimitoshi; Konishi, Tsuzumi; Hirai, Masaru; Kobayashi, Yutaka; Miyagawa, Tomoaki

    2017-02-01

    To assess the value of the Prostate Imaging Reporting and Data System (PI-RADS) scoring system, for prostate multi-parametric magnetic resonance imaging (mpMRI) to detect prostate cancer, and classical parameters, such as prostate-specific antigen (PSA) level, prostate volume and PSA density, for predicting biopsy outcome in biopsy naïve patients who have suspected prostate cancer. Patients who underwent mpMRI at our hospital, and who had their first prostate biopsy between July 2010 and April 2014, were analysed retrospectively. The prostate biopsies were taken transperineally under transrectal ultrasonography guidance. In all, 14 cores were biopsied as a systematic biopsy in all patients. Two cognitive fusion-targeted biopsy cores were added for each lesion in patients who had suspicious or equivocal lesions on mpMRI. The PI-RADS scoring system version 2.0 (PI-RADS v2) was used to describe the MRI findings. Univariate and multivariate analyses were performed to determine significant predictors of prostate cancer and clinically significant prostate cancer. In all, 288 patients were analysed. The median patient age, PSA level, prostate volume and PSA density were 69 years, 7.5 ng/mL, 28.7 mL, and 0.26 ng/mL/mL, respectively. The biopsy results were benign, clinically insignificant, and clinically significant prostate cancer in 129 (45%), 18 (6%) and 141 (49%) patients, respectively. The multivariate analysis revealed that PI-RADS v2 score and PSA density were independent predictors for prostate cancer and clinically significant prostate cancer. When PI-RADS v2 score and PSA density were combined, a PI-RADS v2 score of ≥4 and PSA density ≥0.15 ng/mL/mL, or PI-RADS v2 score of 3 and PSA density of ≥0.30 ng/mL/mL, was associated with the highest clinically significant prostate cancer detection rates (76-97%) on the first biopsy. Of the patients in this group with negative biopsy results, 22% were subsequently diagnosed as prostate cancer. In contrast, a PI

  3. Association between Diastolic Dysfunction with Inflammation and Oxidative Stress in Females ob/ob Mice

    Science.gov (United States)

    Sartori, Michelle; Conti, Filipe F.; Dias, Danielle da Silva; dos Santos, Fernando; Machi, Jacqueline F.; Palomino, Zaira; Casarini, Dulce E.; Rodrigues, Bruno; De Angelis, Kátia; Irigoyen, Maria-Claudia

    2017-01-01

    Objective: To evaluate autonomic and cardiovascular function, as well as inflammatory and oxidative stress markers in ob/ob female mice. Methods: Metabolic parameters, cardiac function, arterial pressure (AP), autonomic, hormonal, inflammatory, and oxidative stress markers were evaluated in 12-weeks female wild-type (WT group) and ob/ob mice (OB group). Results: OB animals showed increased body weight, blood glucose, and triglyceride levels, along with glucose intolerance, when compared to WT animals. Ejection fraction (EF) and AP were similar between groups; however, the OB group presented diastolic dysfunction, as well as an impairment on myocardial performance index. Moreover, the OB group exhibited important autonomic dysfunction and baroreflex sensitivity impairment, when compared to WT group. OB group showed increased Angiotensin II levels in heart and renal tissues; decreased adiponectin and increased inflammatory markers in adipose tissue and spleen. Additionally, OB mice presented a higher damage to proteins and lipoperoxidation and lower activity of antioxidant enzymes in kidney and heart. Correlations were found between autonomic dysfunction with angiotensin II and inflammatory mediators, as well as between inflammation and oxidative stress. Conclusions: Our results showed that female adult ob/ob mice presented discrete diastolic dysfunction accompanied by autonomic disorder, which is associated with inflammation and oxidative stress in these animals. PMID:28878683

  4. Association between Diastolic Dysfunction with Inflammation and Oxidative Stress in Females ob/ob Mice

    Directory of Open Access Journals (Sweden)

    Michelle Sartori

    2017-08-01

    Full Text Available Objective: To evaluate autonomic and cardiovascular function, as well as inflammatory and oxidative stress markers in ob/ob female mice.Methods: Metabolic parameters, cardiac function, arterial pressure (AP, autonomic, hormonal, inflammatory, and oxidative stress markers were evaluated in 12-weeks female wild-type (WT group and ob/ob mice (OB group.Results: OB animals showed increased body weight, blood glucose, and triglyceride levels, along with glucose intolerance, when compared to WT animals. Ejection fraction (EF and AP were similar between groups; however, the OB group presented diastolic dysfunction, as well as an impairment on myocardial performance index. Moreover, the OB group exhibited important autonomic dysfunction and baroreflex sensitivity impairment, when compared to WT group. OB group showed increased Angiotensin II levels in heart and renal tissues; decreased adiponectin and increased inflammatory markers in adipose tissue and spleen. Additionally, OB mice presented a higher damage to proteins and lipoperoxidation and lower activity of antioxidant enzymes in kidney and heart. Correlations were found between autonomic dysfunction with angiotensin II and inflammatory mediators, as well as between inflammation and oxidative stress.Conclusions: Our results showed that female adult ob/ob mice presented discrete diastolic dysfunction accompanied by autonomic disorder, which is associated with inflammation and oxidative stress in these animals.

  5. Sentinel-Lymphknoten-Biopsie des Melanoms mittels Indocyaningrün und "FOVIS"-System.

    Science.gov (United States)

    Göppner, Daniela; Nekwasil, Stephan; Jellestad, Anne; Sachse, Alexander; Schönborn, Karl-Heinz; Gollnick, Harald

    2017-02-01

    Der Nachweis metastatischer Infiltrate im Sentinel-Lymphkoten (SLN) gilt als wesentlicher prognostischer Faktor des Melanoms. Alternativ zur Farbstoffmethode mit Patentblau zum Goldstandard der SLN-Biopsie (SLNB) mittels Radiokolloid wird die fluoreszenzoptische Darstellung mit Hilfe von Indocyaningrün (ICG) und Nahinfrarot (NIR)-Kamerasystem kommuniziert. Im Vergleich zur konventionellen Methode wurde die Wertigkeit des ICG-/NIR-Verfahrens in Abhängigkeit vom Body-Mass-Index (BMI) des Patienten und der Konzentration von ICG bezüglich der Visualisierung des Lymphabstroms und des SLNs untersucht. An zehn Patienten wurde die SLNB mittels Technetium-99m, Patentblau und ICG durchgeführt. Die Fluoreszenz-Darstellung von Lymphbahnen und SLN erfolgte in Echtzeit mittels der NIR-Kameratechnik "FOVIS". Je nach erzielter Bildqualität wurde ICG in einer Dosis von 0,25 mg bis 2,5 mg intrakutan appliziert. Neun der zehn SLN wurden fluoreszenzoptisch identifiziert (90 %), alle zehn radioaktiv (100 %), nur acht (80 %) mittels ICG-Grünfärbung bzw. Patenblau-Markierung. Transdermal wurde ein SLN dargestellt (10 %). In Korrelation zum BMI waren höhere ICG-Mengen, bis zu 2,5 mg intrakutan absolut, in der Darstellung der Lymphbahnen von Vorteil. Die SLN-Fluoreszenzmarkierung mit dem ICG/NIR-Kamera-System "FOVIS" stellt eine sichere Alternative zur Farbstoffmethode mit Patentblau ergänzend zur Radiokolloidmethode mit Technetium-99m dar. Weitere Studien zur optimalen Dosierung von ICG und transdermalen Bildgebung in Relation zum BMI sind notwendig. © 2017 Deutsche Dermatologische Gesellschaft (DDG). Published by John Wiley & Sons Ltd.

  6. Renal biopsy pathology in a cohort of patients from southwest Sydney with clinically diagnosed systemic lupus erythematosus.

    Science.gov (United States)

    Yong, Jim Lc; Killingsworth, Murray C; Lai, Ken

    2013-01-01

    The pathological manifestations in the kidneys in systemic lupus erythematosus (SLE) are commonly known as lupus nephritis. We have studied the pathological changes in renal biopsies from 59 cases of clinically diagnosed SLE obtained over a 15-year period from a racially diverse population in the Sydney metropolitan area. Our aim was to see if there was any regional variation in the morphological changes. Renal biopsy changes were assessed by routine light, immunofluorescence, and electron microscopy. We used the modified 1974 World Health Organization classification of lupus nephritis to classify cases into six classes. Disease severity was assessed by age, sex, and across racial groups, including Caucasian, Asian, Middle Eastern, Mediterranean, Indian subcontinental, South American, and Pacific Islander. Our analysis showed that cases of lupus nephritis contributed 5.4% of our total renal biopsies examined over a 15-year period. The overall incidence of biopsy-proven cases was 0.49 per 100,000 per year. The ages of our patients ranged from 10 to 79 years, with most below 50 years of age. A female to male ratio was determined to be 4.4:1. There was no relationship to ethnicity, nor was there a relationship between any of these parameters and the class or severity of disease. Renal biopsy with multimodal morphological and immunohistochemical analysis remains the gold standard for diagnosis and determination of the level of disease in lupus nephritis. Based on this approach we have identified an incidence rate for southwest Sydney that is slightly higher but comparable to that found in a similar study from the United Kingdom. We also found that there was no relationship between sex, race, or age and severity of disease.

  7. Liver Biopsy

    Science.gov (United States)

    ... called if any of the following occur: ● Persistent abdominal or chest pain ● Vomiting ● Pallor, weakness or dizziness ● Bleeding from the site of the biopsy ● Passage of tarry black stools For more information or to locate a pediatric gastroen- terologist in your area please visit our ...

  8. Controlling the Stormram 2: An MRI-compatible Robotic System for Breast Biopsy

    NARCIS (Netherlands)

    Abdelaziz, Mohamed E.M.K.; Groenhuis, Vincent; Veltman, Jeroen; Siepel, Françoise Jeanette; Stramigioli, Stefano

    2017-01-01

    Breast cancer is the most frequently life-threatening diagnosed type of cancer among women. Early and accurate diagnosis by acquiring a tissue sample using biopsy techniques is essential. However, small lesions only visible by MRI are often missed in standard methods, indicating the need for a

  9. The role of biopsy in the diagnosis of infections of the central nervous system.

    LENUS (Irish Health Repository)

    Jansen, M

    2010-01-01

    CNS infections require prompt appropriate therapy, but do not usually require tissue biopsy for diagnosis. We performed a 5 year audit of CNS infections which required brain or spinal biopsy to determine or confirm a diagnosis of CNS infection. Sixteen cases were identified in which clinical, radiological or additional investigations including culture, serology or PCR for the suspected specific infective agents were not diagnostic. 6 (37.5%) were bacterial abscesses presenting as space-occupying intracerebral lesions with a differential diagnosis of neoplasm. There were 3 (18.7%) cases of toxoplasmosis and 2 (12.5%) cases of aspergillosis. There was one case (6.2%) of herpes simplex encephalitis, one cysticercosis and one progressive multifocal leucoencephalopathy, all biopsied as possible neoplasms. There were 2 (12.5%) cases of spinal tuberculosis, one multifocal, mimicking neurofibromatosis. This review highlights the usefulness of targeted biopsy in the rapid diagnosis of CNS infections. It also emphasizes the lack of specificity of \\'negative\\' culture and serology in certain cases, especially in the setting of immune-compromise.

  10. Prostate biopsy with image fusion: system validation and clinical results (abstract)

    NARCIS (Netherlands)

    Kruecker, J.; Kadoury, S.; Xu, S.; Turkbey, B.; Choyke, P.; Pinto, P.; Wood, B.

    2011-01-01

    Purpose Prostate cancer (PCA) is the second most frequent cause of cancer-related death in men in the United States and Europe. Transrectal ultrasound (TRUS) guided systematic prostate biopsy is the standard of care for detection and diagnosis of PCA. However, due to inadequate visualization of PCA

  11. 2MASS Identifications for Galactic OB Stars

    OpenAIRE

    Reed, B. Cameron

    2007-01-01

    Cross-identifications for 14,574 intrinsically luminous galactic stars (mostly OB stars) to objects in the 2MASS survey have been determined using a search box of +/-0.0015 degrees (+/- 5.4 arcsec) in both RA and Dec. Instructions on obtaining the relevant files can be obtained at othello.alma.edu/~reed/OB-2MASS.doc.

  12. Upgrading and downgrading of prostate cancer from biopsy to radical prostatectomy: incidence and predictive factors using the modified Gleason grading system and factoring in tertiary grades.

    Science.gov (United States)

    Epstein, Jonathan I; Feng, Zhaoyong; Trock, Bruce J; Pierorazio, Phillip M

    2012-05-01

    Prior studies assessing the correlation of Gleason score (GS) at needle biopsy and corresponding radical prostatectomy (RP) predated the use of the modified Gleason scoring system and did not factor in tertiary grade patterns. To assess the relation of biopsy and RP grade in the largest study to date. A total of 7643 totally embedded RP and corresponding needle biopsies (2004-2010) were analyzed according to the updated Gleason system. All patients underwent prostate biopsy prior to RP. The relation of upgrading or downgrading to patient and cancer characteristics was compared using the chi-square test, Student t test, and multivariable logistic regression. A total of 36.3% of cases were upgraded from a needle biopsy GS 5-6 to a higher grade at RP (11.2% with GS 6 plus tertiary). Half of the cases had matching GS 3+4=7 at biopsy and RP with an approximately equal number of cases downgraded and upgraded at RP. With biopsy GS 4+3=7, RP GS was almost equally 3+4=7 and 4+3=7. Biopsy GS 8 led to an almost equal distribution between RP GS 4+3=7, 8, and 9-10. A total of 58% of the cases had matching GS 9-10 at biopsy and RP. In multivariable analysis, increasing age (pfactoring in multiple variables including the number of positive cores and the maximum percentage of cancer per core, the concordance indexes were not sufficiently high to justify the use of nomograms for predicting upgrading and downgrading for the individual patient. Almost 20% of RP cases have tertiary patterns. A needle biopsy can sample a tertiary higher Gleason pattern in the RP, which is then not recorded in the standard GS reporting, resulting in an apparent overgrading on the needle biopsy. Copyright © 2012 European Association of Urology. Published by Elsevier B.V. All rights reserved.

  13. Genetic ablation of phosphatidylcholine transfer protein/StarD2 in ob/ob mice improves glucose tolerance without increasing energy expenditure.

    Science.gov (United States)

    Krisko, Tibor I; LeClair, Katherine B; Cohen, David E

    2017-03-01

    Phosphatidylcholine transfer protein (PC-TP; synonym StarD2) is highly expressed in liver and oxidative tissues. PC-TP promotes hepatic glucose production during fasting and aggravates glucose intolerance in high fat fed mice. However, because PC-TP also suppresses thermogenesis in brown adipose tissue (BAT), its direct contribution to obesity-associated diabetes in mice remains unclear. Here we examined the effects of genetic PC-TP ablation on glucose homeostasis in leptin-deficient ob/ob mice, which exhibit both diabetes and altered thermoregulation. Mice lacking both PC-TP and leptin (Pctp -/- ;ob/ob) were prepared by crossing Pctp -/- with ob/+ mice. Glucose homeostasis was assessed by standard assays, and energy expenditure was determined by indirect calorimetry using a comprehensive laboratory animal monitoring system, which also recorded physical activity and food intake. Body composition was determined by NMR and hepatic lipids by enzymatic assays. Core body temperature was measured using a rectal thermocouple probe. Pctp -/- ;ob/ob mice demonstrated improved glucose homeostasis, as evidenced by markedly improved glucose and pyruvate tolerance tests, without changes in insulin tolerance. However, there were no differences in EE at any ambient temperature. There were also no effects of PC-TP expression on physical activity, food intake or core body temperature. Improved glucose tolerance in Pctp -/- ;ob/ob mice in the absence of increases in energy expenditure or core body temperature indicates a direct pathogenic role for PC-TP in diabetes in leptin deficient mice. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Structural anatomy of telomere OB proteins.

    Science.gov (United States)

    Horvath, Martin P

    2011-10-01

    Telomere DNA-binding proteins protect the ends of chromosomes in eukaryotes. A subset of these proteins are constructed with one or more OB folds and bind with G+T-rich single-stranded DNA found at the extreme termini. The resulting DNA-OB protein complex interacts with other telomere components to coordinate critical telomere functions of DNA protection and DNA synthesis. While the first crystal and NMR structures readily explained protection of telomere ends, the picture of how single-stranded DNA becomes available to serve as primer and template for synthesis of new telomere DNA is only recently coming into focus. New structures of telomere OB fold proteins alongside insights from genetic and biochemical experiments have made significant contributions towards understanding how protein-binding OB proteins collaborate with DNA-binding OB proteins to recruit telomerase and DNA polymerase for telomere homeostasis. This review surveys telomere OB protein structures alongside highly comparable structures derived from replication protein A (RPA) components, with the goal of providing a molecular context for understanding telomere OB protein evolution and mechanism of action in protection and synthesis of telomere DNA.

  15. New Results on the Nearest OB Association: Sco-Cen (Sco OB2)

    Science.gov (United States)

    Mamajek, Eric E.

    2013-01-01

    The Scorpius-Centaurus OB association (Sco OB2) is the nearest site of recent massive star formation to the Sun. The primary stellar groups in the Sco-Cen complex (including OB subgroups Upper Sco, Upper Cen Lup, and Lower Cen Cru, the neighboring molecular cloud complexes Lup, Cha, CrA, Oph, and dispersed young groups Eta Cha, Epsilon Cha, TW Hya, and Beta Pic) have been participants in a complex episode of stellar birth (and some stellar death) over the past ~20 Myr. Here I summarize some recent results on the Sco-Cen complex from the U. Rochester group: (1) isochronal analysis of the HR diagram positions for >1 Msun stars in the Upper Scorpius subgroup shows it to be twice as old as previously thought (11 Myr vs. 5 Myr), (2) analysis of high resolution optical echelle spectra show that the subgroups are approximately solar in composition, (3) surveys for lower mass members are showing that the complex shows more substructure than previously recognized, including at least one new subgroup ("Lower Sco"), and the velocity and age data for the nearest OB subgroup Lower Cen Cru argue for a bifurcation into a younger 10 Myr) southern part ("Crux") and an older 20 Myr) northern part ("Lower Centaurus"), (4) an eclipsing, multi-ring dust disk system was serendipitously discovered in the SuperWASP and ASAS light curve for the newly discovered K5-type Sco-Cen member 1SWASP J140747.93-394542.6. With regard to some recent results by other investigators, we find that (1) attempts by some authors to subsume the Sco-Cen subgroups into a single sample of a single age are unnecessarily mixing samples with a wide range in ages, and (2) I have been unable to replicate the expansion age determinations claimed by some investigators for the TW Hya and Beta Pic groups (both purported to have expansion ages of 8 and 12 Myr, respectively), which have been used by some investigators to independently age-date the Sco-Cen subgroups. We acknowledge support from NSF grant AST-1008908 and the

  16. Hydrogen sulfide improves diabetic wound healing in ob/ob mice via attenuating inflammation.

    Science.gov (United States)

    Zhao, Huichen; Lu, Shengxia; Chai, Jiachao; Zhang, Yuchao; Ma, Xiaoli; Chen, Jicui; Guan, Qingbo; Wan, Meiyan; Liu, Yuantao

    2017-09-01

    The proposed mechanisms of impaired wound healing in diabetes involve sustained inflammation, excess oxidative stress and compromised agiogenesis. Hydrogen sulfide (H 2 S) has been reported to have multiple biological activities. We aim to investigate the role of H 2 S in impaired wound healing in ob/ob mice and explore the possible mechanisms involved. Full-thickness skin dorsal wounds were created on ob/ob mice and C57BL/6 mice. Cystathionine-γ-lyase (CSE) expression and H 2 S production were determined in granulation tissues of the wounds. Effects of NaHS on wound healing were evaluated. Inflammation and angiogenesis in granulation tissues of the wounds were examined. CSE expression, and H 2 S content were significantly reduced in granulation tissues of wounds in ob/ob mice compared with control mice. NaHS treatment significantly improved wound healing in ob/ob mice, which was associated with reduced neutrophil and macrophage infiltration, decreased production of tumor necrosis factor (TNF)-α, interleukin (IL)-6. NaHS treatment decreased metalloproteinase (MMP)-9, whereas increased collagen deposition and vascular-like structures in granulation tissues of wounds in ob/ob mice. CSE down-regulation may play a role in the pathogenesis of diabetic impaired wound healing. Exogenous H 2 S could be a potential agent to improve diabetic impaired wound healing by attenuating inflammation and increasing angiogenesis. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Impaired Muscle Regeneration in Ob/ob and Db/db Mice

    Directory of Open Access Journals (Sweden)

    Mai-Huong Nguyen

    2011-01-01

    Full Text Available In obesity and type 2 diabetes, efficient skeletal muscle repair following injury may be required, not only for restoring muscle structure and function, but also for maintaining exercise capacity and insulin sensitivity. The hypothesis of this study was that muscle regeneration would be impaired in ob/ob and db/db mice, which are common mouse models of obesity and type 2 diabetes. Muscle injury was produced by cardiotoxin injection, and regeneration was assessed by morphological and immunostaining techniques. Muscle regeneration was delayed in ob/ob and db/db mice, but not in a less severe model of insulin resistance – feeding a high-fat diet to wild-type mice. Angiogenesis, cell proliferation, and myoblast accumulation were also impaired in ob/ob and db/db mice, but not the high-fat diet mice. The impairments in muscle regeneration were associated with impaired macrophage accumulation; macrophages have been shown previously to be required for efficient muscle regeneration. Impaired regeneration in ob/ob and db/db mice could be due partly to the lack of leptin signaling, since leptin is expressed both in damaged muscle and in cultured muscle cells. In summary, impaired muscle regeneration in ob/ob and db/db mice was associated with reduced macrophage accumulation, angiogenesis, and myoblast activity, and could have implications for insulin sensitivity in the skeletal muscle of obese and type 2 diabetic patients.

  18. Respiratory bronchiolitis-associated interstitial lung disease secondary to electronic nicotine delivery system use confirmed with open lung biopsy.

    Science.gov (United States)

    Flower, Mark; Nandakumar, Lakshmy; Singh, Mahendra; Wyld, David; Windsor, Morgan; Fielding, David

    2017-05-01

    As a modern phenomenon, there is currently limited understanding of the possible toxic effects and broader implications of electronic nicotine delivery systems (ENDS). Large volumes of aerosolized particles are inhaled during "vaping" and there are now an increasing number of case reports demonstrating toxic effects of ENDS, as well as human studies demonstrating impaired lung function in users. This article presents a case of respiratory bronchiolitis interstitial lung disease (RB-ILD) precipitated by vaping in a 33-year-old male with 10 pack years of traditional cigarette and prior treatment for mixed germ cell tumour. The patient had started vaping 10-15 times per day while continuing to smoke 10 traditional cigarettes per day. After 3 months of exposure to e-cigarette vapour, chest computed tomography demonstrated multiple new poorly defined pulmonary nodules with fluffy parenchyma opacification centred along the terminal bronchovascular units. Video-assisted thoracoscopy with lung biopsy of the right upper and right middle lobes was undertaken. The microscopic findings were overall consistent with RB-ILD. This case demonstrates toxicity with use of ENDS on open lung biopsy with resolution of radiographic findings on cessation. We believe that this is the first case where open lung biopsy has demonstrated this and our findings are consistent with RB-ILD.

  19. MR-guided transgluteal biopsies with an open low-field system in patients with clinically suspected prostate cancer: technique and preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Zangos, Stephan [Johann Wolfgang Goethe-University, Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt/Main (Germany); Johann Wolfgang Goethe-University, Institute for Diagnostic and Interventional Radiology, Frankfurt/Main (Germany); Eichler, Katrin; Engelmann, Kerstin; Ahmed, Mukhtiar; Dettmer, Sebastian; Herzog, Christopher; Pegios, Wasilios; Wetter, A.; Lehnert, Thomas; Mack, Martin G.; Vogl, Thomas J. [Johann Wolfgang Goethe-University, Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt/Main (Germany)

    2005-01-01

    The purpose of this study was to examine the feasibility and safety of MR-guided biopsies with a transgluteal approach in patients with uncertain or suspicious prostate lesions. Twenty-five patients with uncertain or suspicious focal prostate lesions detected by high-field MR imaging of the prostate gland using endorectal coil imaging were biopsied with a transgluteal approach in a low-field MRI system (0.2 T, Concerto, Siemens). The procedures were guided using T1-weighted FLASH sequences. The prostate gland was biopsied repeatedly with a coaxial technique through a 15-gauge pencil tip with a 16-gauge biopsy handy (median 3.8 samples per patient). Complications and biopsy findings were documented retrospectively. Using T1-weighted sequences biopsy procedures were performed successfully with MR guidance in all cases without any side effects or complications. The median intervention time was 11.3 min. Pathological findings revealed ten cases of hyperplasia or atrophy, three cases of prostatitis, ten cases of carcinoma and two cases of normal tissue. The clinical follow-up showed that in two patients prostate cancer was missed at MR-guided biopsy. Transgluteal MR-guided biopsy of the prostate gland is a safe and promising approach for histological clarification of uncertain or suspicious lesions. (orig.)

  20. Renal biopsy pathology in a cohort of patients from southwest Sydney with clinically diagnosed systemic lupus erythematosus

    Directory of Open Access Journals (Sweden)

    Yong JL

    2013-02-01

    Full Text Available Jim LC Yong,1,2 Murray C Killingsworth,1–3 Ken Lai1,21Department of Anatomical Pathology, Sydney South West Pathology Service, 2University of Western Sydney, School of Medicine, 3University of New South Wales, Faculty of Medicine, Sydney, New South Wales, AustraliaPurpose: The pathological manifestations in the kidneys in systemic lupus erythematosus (SLE are commonly known as lupus nephritis. We have studied the pathological changes in renal biopsies from 59 cases of clinically diagnosed SLE obtained over a 15-year period from a racially diverse population in the Sydney metropolitan area. Our aim was to see if there was any regional variation in the morphological changes.Methods: Renal biopsy changes were assessed by routine light, immunofluorescence, and electron microscopy. We used the modified 1974 World Health Organization classification of lupus nephritis to classify cases into six classes. Disease severity was assessed by age, sex, and across racial groups, including Caucasian, Asian, Middle Eastern, Mediterranean, Indian subcontinental, South American, and Pacific Islander.Results: Our analysis showed that cases of lupus nephritis contributed 5.4% of our total renal biopsies examined over a 15-year period. The overall incidence of biopsy-proven cases was 0.49 per 100,000 per year. The ages of our patients ranged from 10 to 79 years, with most below 50 years of age. A female to male ratio was determined to be 4.4:1. There was no relationship to ethnicity, nor was there a relationship between any of these parameters and the class or severity of disease.Conclusion: Renal biopsy with multimodal morphological and immunohistochemical analysis remains the gold standard for diagnosis and determination of the level of disease in lupus nephritis. Based on this approach we have identified an incidence rate for southwest Sydney that is slightly higher but comparable to that found in a similar study from the United Kingdom. We also found that there

  1. Obese diet-induced mouse models of nonalcoholic steatohepatitis-tracking disease by liver biopsy

    Science.gov (United States)

    Kristiansen, Maria Nicoline Baandrup; Veidal, Sanne Skovgård; Rigbolt, Kristoffer Tobias Gustav; Tølbøl, Kirstine Sloth; Roth, Jonathan David; Jelsing, Jacob; Vrang, Niels; Feigh, Michael

    2016-01-01

    AIM: To characterize development of diet-induced nonalcoholic steatohepatitis (NASH) by performing liver biopsy in wild-type and genetically obese mice. METHODS: Male wild-type C57BL/6J (C57) mice (DIO-NASH) and male Lepob/Lepob (ob/ob) mice (ob/ob-NASH) were maintained on a diet high in trans-fat (40%), fructose (22%) and cholesterol (2%) for 26 and 12 wk, respectively. A normal chow diet served as control in C57 mice (lean chow) and ob/ob mice (ob/ob chow). After the diet-induction period, mice were liver biopsied and a blinded histological assessment of steatosis and fibrosis was conducted. Mice were then stratified into groups counterbalanced for steatosis score and fibrosis stage and continued on diet and to receive daily PO dosing of vehicle for 8 wk. Global gene expression in liver tissue was assessed by RNA sequencing and bioinformatics. Metabolic parameters, plasma liver enzymes and lipids (total cholesterol, triglycerides) as well as hepatic lipids and collagen content were measured by biochemical analysis. Non-alcoholic fatty liver disease activity score (NAS) (steatosis/inflammation/ballooning degeneration) and fibrosis were scored. Steatosis and fibrosis were also quantified using percent fractional area. RESULTS: Diet-induction for 26 and 12 wk in DIO-NASH and ob/ob-NASH mice, respectively, elicited progressive metabolic perturbations characterized by increased adiposity, total cholesterol and elevated plasma liver enzymes. The diet also induced clear histological features of NASH including hepatosteatosis and fibrosis. Overall, the metabolic NASH phenotype was more pronounced in ob/ob-NASH vs DIO-NASH mice. During the eight week repeated vehicle dosing period, the metabolic phenotype was sustained in DIO-NASH and ob/ob-NASH mice in conjunction with hepatomegaly and increased hepatic lipids and collagen accumulation. Histopathological scoring demonstrated significantly increased NAS of DIO-NASH mice (0 vs 4.7 ± 0.4, P NASH mice (2.4 ± 0.3 vs 6.3

  2. Sextant localization of prostate cancer in peripheral zone by MRI: correlation with systemic biopsy pathology

    International Nuclear Information System (INIS)

    Huang Rong; Wang Xiaoying; Li Feiyu; Xu Yufeng; Jiang Xuexiang; He Yunfeng; Liu Pengcheng

    2006-01-01

    Objective: To determine the efficacy of sextant localization of prostate cancer (PCa) in PZ (peripheral zone) by MR Imaging. Methods: Fifty-one cases of PCa and 29 cases of benign prostate diseases were enrolled in the study. Each peripheral zone was divided into 6 sections (left/right bottom, middle and tip ) in the same fashion for biopsy and the characteristics of each sextant was evaluated separately. Being blinded to clinical data, 2 radiologists with different subspeciahy experience analyzed MR images of the 480 sections of these 80 cases retrospectively. Each sextant region impression of likelihood for cancer was estimated by the rank of a five-point rating scale (1=definite PCa, 2=probable PCa, 3=possible PCa, 4=probably not PCa, 5=definitely not PCa). If definite PCa was considered, then it was staged furthermore. Each diagnosis of sextant region was compared with the pathological result of corresponding biopsy site. Result: (1) Four hundred and seventy sections (205 cancerous and 265 benign) were proved by biopsy. The diagnosis efficacy was best when cutoff point was 2. There was moderate consistency between the results of MRI and pathology with the kappa value of 0.549-0.560. The total accuracy was 78.1%-78.3% with the sensitivity of 69.3%-76.1% and the specificity of 84.9%-80.0%. The positive predictive value was 78.0%-74.6% and the negative predictive value was 78.1%-81.2%. (2) The ROC analysis demonstrated that Az with total impression recorded by two readers had not significant difference(0.829±0.020 vs. 0.840±0.019, U=-0.3988, P>0.05). Conclusion: MRI may be an elementary way to localize PCa in PZ, but the diagnosis efficacy need to be improved furthermore. (authors)

  3. Oropharynx lesion biopsy

    Science.gov (United States)

    ... as papilloma) Fungal infections (such as candida) Histoplasmosis Oral lichen planus Precancerous sore (leukoplakia) Viral infections (such as Herpes simplex) Risks Risks of the procedure may ... Throat lesion biopsy; Biopsy - mouth or throat; Mouth lesion biopsy; Oral cancer - biopsy ...

  4. Recent Seismic Experiments of OBS in the South China Sea

    Science.gov (United States)

    Ruan, A.; Li, J.; Wu, Z.

    2012-12-01

    Since 2006 some research institutions of China have carried out some important seismic experiments by using ocean bottom seismometer(OBS) in the South China Sea (SCS) and obtained many concrete progresses in modeling the crustal structure of SCS and also in understanding of its formation and evolution as well. In 2006 three wide-angle profiles were completed in the northern margin, named OBS2006-1 across the northwestern sub-basin, OBS2006-2 parallel to the sea basin boundary and OBS2006-3 across the Dongsha Rise and Chaoshan Depression respectively. In 2010 two wide- angle profiles were completed, named OBS2010-1 and OBS 2010-2 both perpendicular to the northern off-shore faulting system. During 2009-2011 four wide-angle profiles were completed in the southern margin, named OBS973-1 from southern margin to the southwestern sub-basin, OBS973-2 from Liyue Bank to the southwestern sub-basin and OBS973-3 from Xisha to the southwestern sub-basin, OBS2011-2 from Xisha to Hainan Island respectively. In 2011 two 3D seismic array of OBS were completed in the Zhongnan-Changlong sea mount chain and Huangyan-Zhenbei sea mount chain respectively. Here we present some primary but important results as follows. (1) The velocity model of OBS2006-1 indicates that the crust under the continental slope decreases from 21km to 11km, and to 7.7km in the northwestern sub-basin with Moho depth ascends from 21km to 11km. The tectonic geometry and velocity structure of the northwestern sub-basin and its margins on both sides shows symmetrical and conjugate and indicates pure shear mode of continental margin rifting mechanism. (2) The velocity model of OBS2006-3 reveals remarkable thickness with maximum 8 km of the Mesozoic sediment in Chaoshan Depression in which velocity increases downward from 4.4 km/s at top to 5.3 km/s at the bottom. The buried depth of Moho decreases from 24-25 km under Dongsha Rise to 17 km in the lower slope and an obviously velocity abnormal is detected in the upper

  5. HSL Attenuates the Follicular Oxidative Stress and Enhances the Hair Growth in ob/ob Mice

    Directory of Open Access Journals (Sweden)

    Takeo Minematsu, PhD

    2013-10-01

    Full Text Available Summary: We demonstrated enhanced hair regeneration following topical administration of N-(3-oxododecanoyl-L-homoserine lactone (HSL in ob/ob mice. The ob/ob mice showed delayed hair regeneration (more than 6 wk after depilation, which rapidly induced transition to anagen in the hair cycle in wild-type mice. Vehicle and HSL solutions were applied to the depilated dorsal skin of ob/ob mice. The depilated skin of the HSL-treated mice was fully covered with hair, whereas no macroscopic alteration was observed in vehicle-treated group by the fourth week after depilation. Oxidative stress was drastically decreased and the expression of the antioxidative enzymes PON1 and PON3 was increased in the HSL-treated skin with highly proliferative anagen follicles. These results suggest that HSL is a candidate therapeutic agent for alopecia in metabolic syndrome.

  6. Serotonin transporter (SERT and translocator protein (TSPO expression in the obese ob/ob mouse

    Directory of Open Access Journals (Sweden)

    Santini Ferruccio

    2011-02-01

    Full Text Available Abstract Background An ever growing body of evidences is emerging concerning metabolism hormones, neurotransmitters or stress-related biomarkers as effective modulators of eating behavior and body weight in mammals. The present study sought at examining the density and affinity of two proteins related to neurotransmission and cell metabolism, the serotonin transporter SERT and the cholesterol import-benzodiazepine site TSPO (translocator protein, in a rodent leptin-lacking mutant, the obese ob/ob mouse. Binding studies were thus carried out in brain or peripheral tissues, blood platelets (SERT and kidneys (TSPO, of ob/ob and WT mice supplied with a standard diet, using the selective radiochemical ligands [3H]-paroxetine and [3H]-PK11195. Results We observed comparable SERT number or affinity in brain and platelets of ob/ob and WT mice, whilst a significantly higher [3H]-PK11195 density was reported in the brain of ob/ob animals. TSPO binding parameters were similar in the kidneys of all tested mice. By [3H]-PK11195 autoradiography of coronal hypothalamic-hippocampal sections, an increased TSPO signal was detected in the dentate gyrus (hippocampus and choroids plexus of ob/ob mice, without appreciable changes in the cortex or hypothalamic-thalamic regions. Conclusions These findings show that TSPO expression is up-regulated in cerebral regions of ob/ob leptin-deficient mice, suggesting a role of the translocator protein in leptin-dependent CNS trophism and metabolism. Unchanged SERT in mutant mice is discussed herein in the context of previous literature as the forerunner to a deeper biochemical investigation.

  7. Ob/ob mouse livers show decreased oxidative phosphorylation efficiencies and anaerobic capacities after cold ischemia.

    Directory of Open Access Journals (Sweden)

    Michael J J Chu

    Full Text Available BACKGROUND: Hepatic steatosis is a major risk factor for graft failure in liver transplantation. Hepatic steatosis shows a greater negative influence on graft function following prolonged cold ischaemia. As the impact of steatosis on hepatocyte metabolism during extended cold ischaemia is not well-described, we compared markers of metabolic capacity and mitochondrial function in steatotic and lean livers following clinically relevant durations of cold preservation. METHODS: Livers from 10-week old leptin-deficient obese (ob/ob, n = 9 and lean C57 mice (n = 9 were preserved in ice-cold University of Wisconsin solution. Liver mitochondrial function was then assessed using high resolution respirometry after 1.5, 3, 5, 8, 12, 16 and 24 hours of storage. Metabolic marker enzymes for anaerobiosis and mitochondrial mass were also measured in conjunction with non-bicarbonate tissue pH buffering capacity. RESULTS: Ob/ob and lean mice livers showed severe (>60% macrovesicular and mild (<30% microvesicular steatosis on Oil Red O staining, respectively. Ob/ob livers had lower baseline enzymatic complex I activity but similar adenosine triphosphate (ATP levels compared to lean livers. During cold storage, the respiratory control ratio and complex I-fueled phosphorylation deteriorated approximately twice as fast in ob/ob livers compared to lean livers. Ob/ob livers also demonstrated decreased ATP production capacities at all time-points analyzed compared to lean livers. Ob/ob liver baseline lactate dehydrogenase activities and intrinsic non-bicarbonate buffering capacities were depressed by 60% and 40%, respectively compared to lean livers. CONCLUSIONS: Steatotic livers have impaired baseline aerobic and anaerobic capacities compared to lean livers, and mitochondrial function indices decrease particularly from after 5 hours of cold preservation. These data provide a mechanistic basis for the clinical recommendation of shorter cold storage durations in

  8. Central Nervous System Involvement of T-cell Prolymphocytic Leukemia Diagnosed with Stereotactic Brain Biopsy: Case Report

    Directory of Open Access Journals (Sweden)

    Selçuk Göçmen

    2014-03-01

    Full Text Available Prolymphocytic leukemia (PLL is a generalized malignancy of the lymphoid tissue characterized by the accumulation of monoclonal lymphocytes, usually of B cell type. Involvement of the central nervous system (CNS is an extremely rare complication of T-cell prolymphocytic leukemia (T-PLL. We describe a case of T-PLL presenting with symptomatic infiltration of the brain that was histopathologically proven by stereotactic brain biopsy. We emphasize the importance of rapid diagnosis and immediate treatment for patients presenting with CNS involvement and a history of leukemia or lymphoma.

  9. Ablation of ghrelin receptor in leptin-deficient ob/ob mice has paradoxical effects on glucose homeostasis when compared with ablation of ghrelin in ob/ob mice

    Science.gov (United States)

    The orexigenic hormone ghrelin is important in diabetes because it has an inhibitory effect on insulin secretion. Ghrelin ablation in leptin-deficient ob/ob (Ghrelin(-/-):ob/ob) mice increases insulin secretion and improves hyperglycemia. The physiologically relevant ghrelin receptor is the growth ...

  10. Stereotactic breast biopsy with a biopsy gun

    International Nuclear Information System (INIS)

    Parker, S.H.; Lovin, J.; Luethke, J.; Jobe, W.E.; Hopper, K.D.; Yakes, W.F.

    1989-01-01

    With the recent introduction of stereotactic mammographic localizing devices, the authors have been performing histologic core needle breast biopsies in which the Bard biopsy gun is used in conjunction with sterotactic guidance. The authors have performed 60 breast gun biopsies with 16-gauge and 18-gauge biopsy-cut needles. These biopsies were followed immediately by traditional surgical excision. Pathologic results correlated well in 52 of the 60 patients, including 10 of 13 cancers. Three of the eight negative correlations occurred when diagnosis was made on gun biopsy but not on surgical biopsy. The stereotactic- guided gun biopsies appear to approach the surgical gold standard, decrease patient discomfort and potential disfigurement, lower the cost of breast biopsy, and lower the threshold necessary to perform breast biopsy

  11. C-arm cone-beam CT combined with a new electromagnetic navigation system for guidance of percutaneous needle biopsies. Initial clinical experience

    International Nuclear Information System (INIS)

    Kickuth, R.; Reichling, C.; Bley, T.; Hahn, D.; Ritter, C.

    2015-01-01

    To evaluate the feasibility and efficacy of C-arm fluoroscopic cone-beam computed tomography (CACT) in combination with a new electromagnetic tracking (EMT) system for needle guidance during percutaneous biopsies. 53 patients were referred for biopsy of thoracic (n = 19) and abdominal (n = 34) lesions. CT-like images of the anatomical region of interest (ROI) were generated using a flat panel-based angiographic system. These images were transmitted to an EMT system. A coaxial puncture needle with a sensor in its tip was connected with the navigation system and tracked into an electromagnetic field created via a field generator. Data generated within this field were merged with the CACT images. On a monitor both the anatomical ROI and needle tip position were displayed to enable precise needle insertion into the target. Through the coaxial needle, biopsy specimens for the histologic evaluation were extracted. Number of representative biopsy samples, number of core biopsies/patient, total procedure time, dose-area product, fluoroscopic time, and complications were recorded. 53 CACT/EMT-guided biopsy procedures were performed, 48 of which (91 %) yielded representative tissue samples. Four core biopsies were obtained from each patient. 40 (75 %) lesions were malignant and 13 (25 %) lesions were benign. The total procedure time was 9 ± 5 min (range, 3 - 23 min), fluoroscopic time was 0.8 ± 0.4 min (range, 0.4 - 2 min). The mean dose-area product (cGy cm 2 ) was 7373 (range, 895 - 26 904). The rate of complications (1 pneumothorax, 2 hemoptyses) was 6 %. CACT combined with EMT appears to be a feasible and effective technique for the guidance of percutaneous biopsies with a low rate of therapeutically relevant complications.

  12. C-arm cone-beam CT combined with a new electromagnetic navigation system for guidance of percutaneous needle biopsies. Initial clinical experience

    Energy Technology Data Exchange (ETDEWEB)

    Kickuth, R.; Reichling, C.; Bley, T.; Hahn, D.; Ritter, C. [University Hospital of Wuerzburg (Germany). Inst. of Diagnostic and Interventional Radiology

    2015-07-15

    To evaluate the feasibility and efficacy of C-arm fluoroscopic cone-beam computed tomography (CACT) in combination with a new electromagnetic tracking (EMT) system for needle guidance during percutaneous biopsies. 53 patients were referred for biopsy of thoracic (n = 19) and abdominal (n = 34) lesions. CT-like images of the anatomical region of interest (ROI) were generated using a flat panel-based angiographic system. These images were transmitted to an EMT system. A coaxial puncture needle with a sensor in its tip was connected with the navigation system and tracked into an electromagnetic field created via a field generator. Data generated within this field were merged with the CACT images. On a monitor both the anatomical ROI and needle tip position were displayed to enable precise needle insertion into the target. Through the coaxial needle, biopsy specimens for the histologic evaluation were extracted. Number of representative biopsy samples, number of core biopsies/patient, total procedure time, dose-area product, fluoroscopic time, and complications were recorded. 53 CACT/EMT-guided biopsy procedures were performed, 48 of which (91 %) yielded representative tissue samples. Four core biopsies were obtained from each patient. 40 (75 %) lesions were malignant and 13 (25 %) lesions were benign. The total procedure time was 9 ± 5 min (range, 3 - 23 min), fluoroscopic time was 0.8 ± 0.4 min (range, 0.4 - 2 min). The mean dose-area product (cGy cm{sup 2}) was 7373 (range, 895 - 26 904). The rate of complications (1 pneumothorax, 2 hemoptyses) was 6 %. CACT combined with EMT appears to be a feasible and effective technique for the guidance of percutaneous biopsies with a low rate of therapeutically relevant complications.

  13. Systemic Lupus Erythematosus and Antineutrophil Cytoplasmic Antibody-Associated Vasculitis Overlap Syndrome in Patients With Biopsy-Proven Glomerulonephritis

    Science.gov (United States)

    Jarrot, Pierre-Andre; Chiche, Laurent; Hervier, Baptiste; Daniel, Laurent; Vuiblet, Vincent; Bardin, Nathalie; Bertin, Daniel; Terrier, Benjamin; Amoura, Zahir; Andrés, Emmanuel; Rondeau, Eric; Hamidou, Mohamed; Pennaforte, Jean-Loup; Halfon, Philippe; Daugas, Eric; Dussol, Bertrand; Puéchal, Xavier; Kaplanski, Gilles; Jourde-Chiche, Noemie

    2016-01-01

    Abstract The aim of the study was to report the clinical, biological, and pathological characteristics of patients with glomerulonephritis (GN) secondary to systemic lupus erythematosus (SLE)/antineutrophil cytoplasmic antibodies (ANCA)-associated vasculitis (AAV) overlap syndrome. A nationwide survey was conducted to identify cases of SLE/AAV overlap syndrome. Data were collected from SLE and AAV French research groups. Inclusion criteria were diagnosis of both SLE and AAV according to international classification criteria and biopsy-proven GN between 1995 and 2014. Additional cases were identified through a systematic literature review. A cohort of consecutive biopsy-proven GN was used to study the prevalence of overlapping antibodies and/or overlap syndrome. The national survey identified 8 cases of SLE/AAV overlap syndrome. All patients were female; median age was 40 years. AAV occurred before SLE (n = 3), after (n = 3), or concomitantly (n = 2). Six patients had rapidly progressive GN and 3/8 had alveolar hemorrhage. All patients had antinuclear antibodies (ANA); 7/8 had p-ANCA antimyeloperoxidase (MPO) antibodies. Renal biopsies showed lupus nephritis (LN) or pauci-immune GN. Remission was obtained in 4/8 patients. A literature review identified 31 additional cases with a similarly severe presentation. In the GN cohort, ANCA positivity was found in 30% of LN, ANA positivity in 52% of pauci-immune GN, with no correlation with pathological findings. The estimated prevalence for SLE/AAV overlap syndrome was 2/101 (2%). In patients with GN, SLE/AAV overlap syndrome may occur but with a low prevalence. Most patients have an aggressive renal presentation, with usually both ANA and anti-MPO antibodies. Further studies are needed to assess shared pathogenesis and therapeutic options. PMID:27258503

  14. Biopsy-proven case of Epstein-Barr virus (EBV)-associated vasculitis of the central nervous system.

    Science.gov (United States)

    Kano, Kohei; Katayama, Takayuki; Takeguchi, Shiori; Asanome, Asuka; Takahashi, Kae; Saito, Tsukasa; Sawada, Jun; Saito, Masato; Anei, Ryogo; Kamada, Kyousuke; Miyokawa, Naoyuki; Nishihara, Hiroshi; Hasebe, Naoyuki

    2017-06-01

    A 75-year-old woman was admitted to our hospital with rapidly deteriorating consciousness disturbance. She had a 7-year history of rheumatoid arthritis (RA), which had been treated with methotrexate (MTX) and prednisolone. Brain T2-weighted MRI showed diffuse high-intensity lesions in the cerebral subcortical and deep white matter, bilateral basal ganglia and thalamus. A cerebrospinal fluid examination revealed elevated protein levels and positive Epstein-Barr virus (EBV) DNA. Human immunodeficiency virus was negative. Brain biopsy showed perivascular lymphocytic infiltration in the parenchyma and meninx with EBV-encoded small RNA (EBER). Since this case did not fulfill the criteria for chronic active EBV infection (CAEBV), she was diagnosed with Epstein-Barr virus (EBV)-associated vasculitis of the central nervous system. High-dose methylprednisolone, acyclovir, ganciclovir and foscarnet were not effective. Although EBV is a causative agent of infectious mononucleosis (IM), lymphomas and nasopharyngeal carcinomas, vasculitic pathology of the central nervous system with EBV reactivation in the elderly is rare. Immunosuppressive drugs such as steroids and MTX are widely used to treat autoimmune disorders, but may exacerbate the reactivation of EBV. This is the first case of biopsy-proven EBV-positive/HIV-negative vasculitis during the treatment of RA with MTX and steroids. This case indicates that EBV-associated vasculitis needs to be considered as a differential diagnosis of CNS vasculitis. © 2016 Japanese Society of Neuropathology.

  15. Real-time navigation system for sentinel lymph node biopsy in breast cancer patients using projection mapping with indocyanine green fluorescence.

    Science.gov (United States)

    Takada, Masahiro; Takeuchi, Megumi; Suzuki, Eiji; Sato, Fumiaki; Matsumoto, Yoshiaki; Torii, Masae; Kawaguchi-Sakita, Nobuko; Nishino, Hiroto; Seo, Satoru; Hatano, Etsuro; Toi, Masakazu

    2018-05-09

    Inability to visualize indocyanine green fluorescence images in the surgical field limits the application of current near-infrared fluorescence imaging (NIR) systems for real-time navigation during sentinel lymph node (SLN) biopsy in breast cancer patients. The aim of this study was to evaluate the usefulness of the Medical Imaging Projection System (MIPS), which uses active projection mapping, for SLN biopsy. A total of 56 patients (59 procedures) underwent SLN biopsy using the MIPS between March 2016 and November 2017. After SLN biopsy using the MIPS, residual SLNs were removed using a conventional NIR camera and/or radioisotope method. The primary endpoint of this study was identification rate of SLNs using the MIPS. In all procedures, at least one SLN was detected by the MIPS, giving an SLN identification rate of 100% [95% confidence interval (CI) 94-100%]. SLN biopsy was successfully performed without operating lights in all procedures. In total, 3 positive SLNs were excised using MIPS, but were not included in the additional SLNs excised by other methods. The median number of SLNs excised using the MIPS was 3 (range 1-7). Of procedures performed after preoperative systemic therapy, the median number of SLNs excised using the MIPS was 3 (range 2-6). The MIPS is effective in detecting SLNs in patients with breast cancer, providing continuous and accurate projection of fluorescence signals in the surgical field, without need for operating lights, and could be useful in real-time navigation surgery for SLN biopsy.

  16. OBS Technologies and permanent seismic Stations at Sea

    Science.gov (United States)

    Makris, J.; Nikolova, S. B.

    2003-04-01

    An off-shore telemetric system was developed during last 2 years. It consists of a buoy unit, OBS with seismic sensor and digitizer at the sea floor and coaxial cable for transferring data from the sea. The buoy unit includes all components for recording and transmitting data to the base station. A solar panel and wind generator are the sources of energy that charge the batteries in the buoy. An Omni directional antenna and a radio modem are used for data transfer. The buoy can be connected also to mobile network or satellite. The Seismic recording unit is SEDIS IV developed in GeoPro GmbH which is a 6 channel data logger equipped with a hard disk of 30 GByte capacity and a flash memory of 0.5 Gbyte which can continuously record at different sampling rate (from 31.25 to 1000sps). The operating system for SEDIS IV is LINUX, with possible data compression, event location and extraction. The data transfer and supply of the power to seismometer and ADC unit in OBS sphere is done through coaxial cable, connecting the buoy unit and OBS. The whole system was tested for a period of one month (October 2002) within frame of Nestor program in Pilos (Greece) and worked successfully.

  17. ADDITIONAL MASSIVE BINARIES IN THE CYGNUS OB2 ASSOCIATION

    International Nuclear Information System (INIS)

    Kiminki, Daniel C.; Kobulnicky, Henry A.; Ewing, Ian; Lundquist, Michael; Alexander, Michael; Vargas-Alvarez, Carlos; Choi, Heather; Bagley Kiminki, Megan M.; Henderson, C. B.

    2012-01-01

    We report the discovery and orbital solutions for two new OB binaries in the Cygnus OB2 Association, MT311 (B2V + B3V) and MT605 (B0.5V + B2.5:V). We also identify the system MT429 as a probable triple system consisting of a tight eclipsing 2.97 day B3V+B6V pair and a B0V at a projected separation of 138 AU. We further provide the first spectroscopic orbital solutions to the eclipsing, double-lined, O-star binary MT696 (O9.5V + B1:V), the double-lined, early B binary MT720 (B0-1V + B1-2V), and the double-lined, O-star binary MT771 (O7V + O9V). These systems exhibit orbital periods between 1.5 days and 12.3 days, with the majority having P <6 days. The two new binary discoveries and six spectroscopic solutions bring the total number of known massive binaries in the central region of the Cygnus OB2 Association to 20, with all but two having full orbital solutions.

  18. ADDITIONAL MASSIVE BINARIES IN THE CYGNUS OB2 ASSOCIATION

    Energy Technology Data Exchange (ETDEWEB)

    Kiminki, Daniel C.; Kobulnicky, Henry A.; Ewing, Ian; Lundquist, Michael; Alexander, Michael; Vargas-Alvarez, Carlos; Choi, Heather [Department of Physics and Astronomy, University of Wyoming, Laramie, WY 82070 (United States); Bagley Kiminki, Megan M. [Department of Astronomy, University of Arizona, Tucson, AZ 85721 (United States); Henderson, C. B. [Department of Astronomy, Ohio State University, Columbus, OH 43210 (United States)

    2012-03-01

    We report the discovery and orbital solutions for two new OB binaries in the Cygnus OB2 Association, MT311 (B2V + B3V) and MT605 (B0.5V + B2.5:V). We also identify the system MT429 as a probable triple system consisting of a tight eclipsing 2.97 day B3V+B6V pair and a B0V at a projected separation of 138 AU. We further provide the first spectroscopic orbital solutions to the eclipsing, double-lined, O-star binary MT696 (O9.5V + B1:V), the double-lined, early B binary MT720 (B0-1V + B1-2V), and the double-lined, O-star binary MT771 (O7V + O9V). These systems exhibit orbital periods between 1.5 days and 12.3 days, with the majority having P <6 days. The two new binary discoveries and six spectroscopic solutions bring the total number of known massive binaries in the central region of the Cygnus OB2 Association to 20, with all but two having full orbital solutions.

  19. Effect of Mixed Glass Former on Ionic Conductivity of Silver Boro Tungstate glass system x[0.75AgI:0.25AgCl]: (1-x) [Ag2O-{B2O3:WO3}

    Science.gov (United States)

    Dehariya, Harsha; Kumar, R.; Polu, A. R.

    2012-05-01

    The idea to explore new 'Superionic Electrolytes', "Fast ionic conductors" is due to their tremendous potential applications in solid state electrochemical devices viz. solid state batteries, fuel cells, sensors, super capacitors. Superionic glasses have attracted great deal of attention due to their several advantageous over their crystalline counterparts such as high ionic conductivity, easy preparation, wide selection of compositions, isotropic properties and high stability etc [4-7]. Large numbers of silver ion based glasses have been reported in the literature for the glassy system of AgI:Ag2O: MxOy (MxOy = B2O3, SiO2, P2O5, GeO2, V2O5, As2O5, CrO3, SeO2, MoO3 & TeO3 etc many of them shows high silver ion conductivity [8]. Ion transport behavior of Silver Boro Tungstate glass system x[0.75AgI:0.25AgCl]: (1-x) [Ag2O{B2O3:WO3}], where 0 <= x <= 1 in molar wt% prepared by melt quench technique were reported. The new host [0.75AgI:0.25AgCl] was used as a better alternate in place of conventional host salt AgI. Conductivity measurement were carried out on this glass system as a function of frequency from 50 Hz to 5 MHz, over a temperature range of 27°C to 200°C, for different compositions by Impedance spectroscopy. The composition 0.7[0.75AgI:0.25AgCl]: 0.3[Ag2O{B2O3:WO3}] shows the highest conductivity of the order of σrt ~ 2.76 × 10-2 S/cm, referred to as the Optimum Conducting Composition (OCC). The enhancement in the conductivity has been obtained by mixed former effect. XRD result shows that the system is completely amorphous. Temperature dependence of conductivity of all compositions were studied & reported. Activation energies (Ea) were also evaluated from the slope of .Log(σ) vs 1000/T, Arrhenius plots.

  20. Effect of Mixed Glass Former on Ionic Conductivity of Silver Boron Tungstate glass system x[0.75AgI:0.25AgCl]: (1-x) [Ag2O-(B2O3:WO3)

    International Nuclear Information System (INIS)

    Dehariya, Harsha; Kumar, R; Polu, A R

    2012-01-01

    The idea to explore new 'Superionic Electrolytes', 'Fast ionic conductors' is due to their tremendous potential applications in solid state electrochemical devices viz. solid state batteries, fuel cells, sensors, super capacitors. Superionic glasses have attracted great deal of attention due to their several advantageous over their crystalline counterparts such as high ionic conductivity, easy preparation, wide selection of compositions, isotropic properties and high stability etc [4-7]. Large numbers of silver ion based glasses have been reported in the literature for the glassy system of AgI:Ag2O: MxOy (MxOy = B2O3, SiO2, P2O5, GeO2, V2O5, As2O5, CrO3, SeO2, MoO3 and TeO3 etc many of them shows high silver ion conductivity [8]. Ion transport behavior of Silver Boro Tungstate glass system x[0.75AgI:0.25AgCl]: (1-x) [Ag2O(B2O3:WO3)], where 0 ≤ x ≤ 1 in molar wt% prepared by melt quench technique were reported. The new host [0.75AgI:0.25AgCl] was used as a better alternate in place of conventional host salt AgI. Conductivity measurement were carried out on this glass system as a function of frequency from 50 Hz to 5 MHz, over a temperature range of 27 C to 200 C, for different compositions by Impedance spectroscopy. The composition 0.7[0.75AgI:0.25AgCl]: 0.3[Ag2O(B2O3:WO3)] shows the highest conductivity of the order of σrt ∼ 2.76x10-2 S/cm, referred to as the Optimum Conducting Composition (OCC). The enhancement in the conductivity has been obtained by mixed former effect. XRD result shows that the system is completely amorphous. Temperature dependence of conductivity of all compositions were studied and reported. Activation energies (Ea) were also evaluated from the slope of .Log(σ) vs 1000/T, Arrhenius plots.

  1. MR-guided preoperative localization and percutaneous core biopsy of suspicious breast lesions - experience on the vertically open 0.5 T system

    International Nuclear Information System (INIS)

    Schneider, J.P.; Schulz, T.; Rueger, S.; Schmidt, F.; Kahn, T.; Leinung, S.; Briest, S.

    2002-01-01

    Purpose. To evaluate the feasibility of performing breast interventions in a vertically open 0.5 T MR system (SIGNA SP/i, GE Medical Systems). To develop fitted equipment and to establish preoperative wire localization and percutaneous breast core biopsy as clinical routine procedures. Patients and methods. Initially, we applied a localization method with the patient placed in a sitting position in 31 cases using a single loop coil and a self-developed fixation device. Subsequently, 46 wire localizations and 28 percutaneous core biopsies were carried out in prone patient position using an open breast coil with an integrated biopsy device. The used instruments were either MR-compatible (18 G biopsy needle and localization wire, 14 G coaxial needle, prototype of a 16 G double-shoot gun) or MR-safe (double-shoot gun with 16 G needle). Results. After biopsy we found the needle tip (18 G for a wire localization and 14 G for a percutaneous core biopsy, respectively) placed either within or close to the lesions ( [de

  2. Preliminary clinical experience with a dedicated interventional robotic system for CT-guided biopsies of lung lesions: a comparison with the conventional manual technique

    International Nuclear Information System (INIS)

    Anzidei, Michele; Argiro, Renato; Porfiri, Andrea; Boni, Fabrizio; Zaccagna, Fulvio; Napoli, Alessandro; Leonardi, Andrea; Bezzi, Mario; Catalano, Carlo; Anile, Marco; Venuta, Federico; Vitolo, Domenico; Saba, Luca; Longo, Flavia

    2015-01-01

    Evaluate the performance of a robotic system for CT-guided lung biopsy in comparison to the conventional manual technique. One hundred patients referred for CT-guided lung biopsy were randomly assigned to group A (robot-assisted procedure) or group B (conventional procedure). Size, distance from entry point and position in lung of target lesions were evaluated to assess homogeneity differences between the two groups. Procedure duration, dose length product (DLP), precision of needle positioning, diagnostic performance of the biopsy and rate of complications were evaluated to assess the clinical performance of the robotic system as compared to the conventional technique. All biopsies were successfully performed. The size (p = 0.41), distance from entry point (p = 0.86) and position in lung (p = 0.32) of target lesions were similar in both groups (p = 0.05). Procedure duration and radiation dose were significantly reduced in group A as compared to group B (p = 0.001). Precision of needle positioning, diagnostic performance of the biopsy and rate of complications were similar in both groups (p = 0.05). Robot-assisted CT-guided lung biopsy can be performed safely and with high diagnostic accuracy, reducing procedure duration and radiation dose in comparison to the conventional manual technique. (orig.)

  3. Preliminary clinical experience with a dedicated interventional robotic system for CT-guided biopsies of lung lesions: a comparison with the conventional manual technique

    Energy Technology Data Exchange (ETDEWEB)

    Anzidei, Michele; Argiro, Renato; Porfiri, Andrea; Boni, Fabrizio; Zaccagna, Fulvio; Napoli, Alessandro; Leonardi, Andrea; Bezzi, Mario; Catalano, Carlo [University of Rome, Department of Radiological, Oncological and Anatomopathological Sciences - Radiology - Sapienza, Rome (Italy); Anile, Marco; Venuta, Federico [University of Rome, Department of Thoracic Surgery - Sapienza, Rome (Italy); Vitolo, Domenico [University of Rome, Department of Radiological, Oncological and Anatomopathological Sciences - Pathology - Sapienza, Rome (Italy); Saba, Luca [Department of Radiology, Azienda Ospedaliero Universitaria (A.O.U.), di Cagliari-Polo di Monserrato, Monserrato (Italy); Longo, Flavia [University of Rome, Department of Radiological, Oncological and Anatomopathological Sciences - Oncology - Sapienza, Rome (Italy)

    2015-05-01

    Evaluate the performance of a robotic system for CT-guided lung biopsy in comparison to the conventional manual technique. One hundred patients referred for CT-guided lung biopsy were randomly assigned to group A (robot-assisted procedure) or group B (conventional procedure). Size, distance from entry point and position in lung of target lesions were evaluated to assess homogeneity differences between the two groups. Procedure duration, dose length product (DLP), precision of needle positioning, diagnostic performance of the biopsy and rate of complications were evaluated to assess the clinical performance of the robotic system as compared to the conventional technique. All biopsies were successfully performed. The size (p = 0.41), distance from entry point (p = 0.86) and position in lung (p = 0.32) of target lesions were similar in both groups (p = 0.05). Procedure duration and radiation dose were significantly reduced in group A as compared to group B (p = 0.001). Precision of needle positioning, diagnostic performance of the biopsy and rate of complications were similar in both groups (p = 0.05). Robot-assisted CT-guided lung biopsy can be performed safely and with high diagnostic accuracy, reducing procedure duration and radiation dose in comparison to the conventional manual technique. (orig.)

  4. iNOS inhibits hair regeneration in obese diabetic (ob/ob) mice.

    Science.gov (United States)

    Sasaki, Mari; Shinozaki, Shohei; Morinaga, Hironobu; Kaneki, Masao; Nishimura, Emi; Shimokado, Kentaro

    2018-07-02

    Previous studies have shown that androgenic alopecia is associated with metabolic syndrome and diabetes. However, the detailed mechanism whereby diabetes causes alopecia still remains unclear. We focused on the inflammatory response that is caused by diabetes or obesity, given that inflammation is a risk factor for hair loss. Inducible nitric oxide synthase (iNOS) is known to be upregulated under conditions of acute or chronic inflammation. To clarify the potential role of iNOS in diabetes-related alopecia, we generated obese diabetic iNOS-deficient (ob/ob; iNOS-KO mice). We observed that ob/ob; iNOS-KO mice were potentiated for the transition from telogen (rest phase) to anagen (growth phase) in the hair cycle compared with iNOS-proficient ob/ob mice. To determine the effect of nitric oxide (NO) on the hair cycle, we administered an iNOS inhibitor intraperitoneally (compound 1400 W, 10 mg/kg) or topically (10% aminoguanidine) in ob/ob mice. We observed that iNOS inhibitors promoted anagen transition in ob/ob mice. Next, we administered an NO donor (S-nitrosoglutathione, GSNO), to test whether NO has the telogen elongation effects. The NO donor was sufficient to induce telogen elongation in wild-type mice. Together, our data indicate that iNOS-derived NO plays a role in telogen elongation under the inflammatory conditions associated with diabetes in mice. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.

  5. Stereotactic biopsy

    International Nuclear Information System (INIS)

    Mwangi, M.N.; Handa, A.

    2006-01-01

    This technology is capable of locating lesions precise detected by the mammography examinations. This devise allows the surgeon to position automatically the needle to perform the cytological/histological biopsy with maximum position accuracy. This is under sterile procedure. to position the lesion in the beam, two radiographic procedures are carried out: the first with the X-ray beam at an inclination of -15 degrees with respect to the position 0 degrees and the second at the inclination +15 degrees. After processing the film the lesion will appear on both radiographs but on light are of the negatoscope. With the cursor information is fed from four points. On the display the length of the needle will appear immediately. The length of the needle to be used in suction is chosen on the basis of the two values on the display. This information fed on the control panel will move the needle unit position where the lesion is. the needle is then introduced under local anaesthesia at the preselected length until it clicks into position. An exposure is made with needle in situ in position at +15 degrees and -15 degrees to ensure the needle is in position. the suction is then carried out and the needle removed. The machine is then reset to return at the initial position

  6. Biopsy-proven case of childhood primary angiitis of the central nervous system presenting with bilateral panuveitis and anisocoria

    Energy Technology Data Exchange (ETDEWEB)

    Saettele, Megan R. [University of Missouri-Kansas City School of Medicine, Department of Radiology, Kansas City, MO (United States); St. Luke' s Hospital, Department of Radiology, Kansas City, MO (United States); Loskutov, Anatoly; Sigley, Matthew J. [University of Missouri-Kansas City School of Medicine, Department of Radiology, Kansas City, MO (United States); Lowe, Lisa H. [St. Luke' s Hospital, Department of Radiology, Kansas City, MO (United States); University of Missouri-Kansas City School of Medicine, Department of Radiology, Kansas City, MO (United States); Children' s Mercy Hospitals and Clinics, Department of Radiology, Kansas City, MO (United States); Nielsen, David B. [University of Missouri-Kansas City School of Medicine, Department of Radiology, Kansas City, MO (United States); Children' s Mercy Hospitals and Clinics, Department of Radiology, Kansas City, MO (United States)

    2014-06-25

    Childhood primary angiitis of the central nervous system (cPACNS) is a rare and poorly understood immune-mediated vasculitis that preferentially affects blood vessels of the central nervous system (CNS). It must be distinguished from other disorders to initiate prompt treatment and improve the patient's prognosis. The presentation of cPACNS is highly variable, making a clinical diagnosis challenging. However, MRI may be helpful in showing typical findings including perivascular space inflammation and enhancement. Identification of these imaging features allows the radiologist to specifically suggest this rare diagnosis. The purpose of this manuscript is to present a biopsy-confirmed case of cPACNS in a 9-year-old girl who presented uniquely with panuveitis and anisocoria, and emphasize the MRI features that should prompt the radiologist to suggest this rare diagnosis. (orig.)

  7. Biopsy-proven case of childhood primary angiitis of the central nervous system presenting with bilateral panuveitis and anisocoria

    International Nuclear Information System (INIS)

    Saettele, Megan R.; Loskutov, Anatoly; Sigley, Matthew J.; Lowe, Lisa H.; Nielsen, David B.

    2015-01-01

    Childhood primary angiitis of the central nervous system (cPACNS) is a rare and poorly understood immune-mediated vasculitis that preferentially affects blood vessels of the central nervous system (CNS). It must be distinguished from other disorders to initiate prompt treatment and improve the patient's prognosis. The presentation of cPACNS is highly variable, making a clinical diagnosis challenging. However, MRI may be helpful in showing typical findings including perivascular space inflammation and enhancement. Identification of these imaging features allows the radiologist to specifically suggest this rare diagnosis. The purpose of this manuscript is to present a biopsy-confirmed case of cPACNS in a 9-year-old girl who presented uniquely with panuveitis and anisocoria, and emphasize the MRI features that should prompt the radiologist to suggest this rare diagnosis. (orig.)

  8. Sequential formation of subgroups in OB associations

    International Nuclear Information System (INIS)

    Elmegreen, B.G.; Lada, C.J.

    1977-01-01

    We reconsider the structure and formation of OB association in view of recent radio and infrared observations of the adjacent molecular clouds. As a result of this reexamination, we propose that OB subgroups are formed in a step-by-step process which involves the propagation of ionization (I) and shock (S) fronts through a molecular cloud complex. OB stars formed at the edge of a molecular cloud drive these I-S fronts into the cloud. A layer of dense neutral material accumulates between the I and S fronts and eventually becomes gravitationally unstable. This process is analyzed in detail. Several arguments concerning the temperature and mass of this layer suggest that a new OB subgroup will form. After approximately one-half million years, these stars will emerge from and disrupt the star-forming layer. A new shock will be driven into the remaining molecular cloud and will initiate another cycle of star formation.Several observed properties of OB associations are shown to follow from a sequential star-forming mechanism. These include the spatial separation and systematic differences in age of OB subgroups in a given association, the regularity of subgroup masses, the alignment of subgroups along the galactic plane, and their physical expansion. Detailed observations of ionization fronts, masers, IR sources, and molecular clouds are also in agreement with this model. Finally, this mechanism provides a means of dissipating a molecular cloud and exposing less massive stars (e.g., T Tauri stars) which may have formed ahead of the shock as part of the original cloud collapsed and fragmented

  9. Star formation in the Monoceros OB1 dark cloud

    International Nuclear Information System (INIS)

    Margulis, M.S.

    1987-01-01

    A survey of the Monoceros OB1 dark cloud was made for molecular outflows and young stellar objects. In all, nine molecular outflows and thirty far-infrared sources were identified in a portion of the cloud composed of about 3 x 10 4 M of material. Statistical arguments suggest that 90% of the far-infrared sources actually are young stellar objects embedded in the cloud. If the star formation rate in the Mon OB1 cloud is roughly constant with time, then molecular outflows in the cloud should be able to support it against collapse due to gravity. This suggests that the birthrate of outflows in the solar neighborhood is very high. In fact, regardless of considerations of cloud support, the large number of outflows identified in the Mon OB1 cloud and the propensity of the youngest stellar objects in the cloud to be associated with outflows suggest that outflows have a high birthrate in the solar neighborhood and are part of a common stage in early stellar evolution. The young stellar objects identified in the cloud can be fit into a spectral classification system. Also, the outflow phase in early stellar evolution tends to occur at about the time that young stellar objects lose a large fraction of their circumstellar envelopes

  10. Open lung biopsy

    Science.gov (United States)

    Biopsy - open lung ... An open lung biopsy is done in the hospital using general anesthesia . This means you will be asleep and ... The open lung biopsy is done to evaluate lung problems seen on x-ray or CT scan .

  11. Bone lesion biopsy

    Science.gov (United States)

    Bone biopsy; Biopsy - bone ... the cut, then pushed and twisted into the bone. Once the sample is obtained, the needle is ... sample is sent to a lab for examination. Bone biopsy may also be done under general anesthesia ...

  12. Liquid biopsy for brain tumors

    Science.gov (United States)

    Shankar, Ganesh M.; Balaj, Leonora; Stott, Shannon L.; Nahed, Brian; Carter, Bob S.

    2018-01-01

    Introduction Minimally invasive methods will augment the clinical approach for establishing the diagnosis or monitoring treatment response of central nervous system tumors. Liquid biopsy by blood or cerebrospinal fluid sampling holds promise in this regard. Areas covered In this literature review, the authors highlight recent studies describing the analysis of circulating tumor cells, cell free nucleic acids, and extracellular vesicles as strategies to accomplish liquid biopsy in glioblastoma and metastatic tumors. The authors then discuss the continued efforts to improve signal detection, standardize the liquid biopsy handling and preparation, develop platforms for clinical application, and establish a role for liquid biopsies in personalized medicine. Expert commentary As the technologies used to analyze these biomarkers continue to evolve, we propose that there is a future potential to precisely diagnose and monitor treatment response with liquid biopsies. PMID:28875730

  13. Evidence for circumstellar obscuration of OB stars

    International Nuclear Information System (INIS)

    Bohannan, B.

    1975-01-01

    Reddish found a strong increase of color excess with increasing stellar luminosity: here referred to as the Reddish Effect: in ten young galactic clusters and associations. New photometric and spectroscopic observations drawn from the literature are combined with data used by Reddish to reconsider the color excess versus intrinsic magnitude diagrams of the same ten stellar groups. The reality of the Effect is questioned in all but one of the systems; this was accomplished by identifying possible foreground stars and by recognizing some of the brightest stars as supergiants, then applying correct intrinsic color indices. After careful reanalysis, the one stellar group to retain an indication of the Reddish Effect is Cygnus OB2. No correlation of reddening with luminosity was found for five additional very young stellar groups in the southern hemisphere; these groups should exhibit the Effect if it is a natural consequence of stellar evolution. Reddish ascribed the correlation to massive circumstellar remnants of material from which the stars formed. However, a peculiar dispersion in color excess could also be attributed to patchy dust within the stellar group. In several stellar systems previously identified as displaying the Reddish Effect, a correlation of observed color excess with dust and gas concentrations is noted on Palomar Sky Survey prints. If present, circumstellar dust clouds should []anifest their existence in modes other than a correlation of color excess with luminosity. The following possibilities are considered and all show negative results: correlation of color excess with spectral type; correlation of reddening slope E/subU//sub -//subB//E/subB//sub -//subV/ with spectral type; observable infrared excess. The preceding astrophysical arguments strongly imply that circumstellar dust remnants from stellar formation do not remain around stars during their main-sequence lifetimes. (auth)

  14. Initial Experience Performing In-office Ultrasound-guided Transperineal Prostate Biopsy Under Local Anesthesia Using the PrecisionPoint Transperineal Access System.

    Science.gov (United States)

    Meyer, Alexa R; Joice, Gregory A; Schwen, Zeyad R; Partin, Alan W; Allaf, Mohamad E; Gorin, Michael A

    2018-05-01

    To describe our procedural technique and initial outcomes performing in-office transperineal prostate biopsies using the PrecisionPoint Transperineal Access System (Perineologic, Cumberland, MD). Following institutional review board approval, we retrospectively reviewed the records of men who underwent an in-office transperineal prostate biopsy using the PrecisionPoint device. Records were reviewed for baseline characteristics, biopsy results, and postbiopsy complications. Between January 4, 2017 and August 23, 2017, 43 men underwent an in-office transperineal prostate biopsy using the PrecisionPoint Transperineal Access System. Patients had a median serum prostate specific antigen level of 6.1 ng/mL (range 0.8-32.9). Of the 43 biopsies, 12 (27.9%) were performed for active surveillance of low-risk prostate cancer and 31 (72.1%) were performed for cancer screening. Overall, 21 (48.8%) men were found to have prostate cancer. Among those on active surveillance, cancer was detected in 8 of 12 (66.7%) patients, with 2 of 12 (16.7%) found to have Gleason ≥3 + 4 = 7 prostate cancer. Additionally, cancer was detected in 13 of 31 (41.9%) patients undergoing a biopsy for prostate cancer screening, with 5 (16.1%) found to have Gleason ≥3 + 4 = 7 disease. In total, 3 (7.0%) patients experienced a postbiopsy complication: 2 (4.7%) with urinary retention and 1 (2.3%) with gross hematuria requiring catheterization. No patient experienced an infectious complication despite omission of periprocedural antibiotics in all cases. The PrecisionPoint device allowed for the successful performance of in-office transperineal prostate biopsies under local anesthesia without the need for periprocedural antibiotics. We observed an acceptable cancer detection rate with no infectious complications. Copyright © 2018 Elsevier Inc. All rights reserved.

  15. Biopsy Diagnosis of Oral Carcinoma by the Combination of Morphological and Spectral Methods Based on Embedded Relay Lens Microscopic Hyperspectral Imaging System.

    Science.gov (United States)

    Ou-Yang, Mang; Hsieh, Yao-Fang; Lee, Cheng-Chung

    Cytopathological examination through biopsy is very important for carcinoma detection. The embedded relay lens microscopic hyperspectral imaging system (ERL-MHIS) provides a morphological image of a biopsy sample and the spectrum of each pixel in the image simultaneously. Based on the ERL-MHIS, this work develops morphological and spectral methods to diagnose oral carcinoma biopsy. In morphological discrimination, the fractal dimension method is applied to differentiate between normal and abnormal tissues. In spectral identification, normal and cancerous cells are distinguished using five methods. However, the spectra of normal and cancerous cells vary with patient. The diagnostic performances of the five methods are thus not ideal. Hence, the proposed cocktail approach is used to determine the effectiveness of the spectral methods in correlating with the sampling conditions. And then we use a combination of effective spectral methods according to the sample conditions for diagnosing a sample. A total of 68 biopsies from 34 patients are analyzed using the ERL-MHIS. The results demonstrate a sensitivity of 90 ± 4.53 % and a specificity of 87.8 ± 5.21 %. Furthermore, in our survey, this system is the first time utilized to study oral carcinoma biopsies.

  16. uvby and JHKL photometry of OB stars in the association Cygnus OB2

    International Nuclear Information System (INIS)

    Torres-Dodgen, A.V.; Carroll, M.; Tapia, M.

    1991-01-01

    We have obtained uvby and JHK photometry of about 80 stars in the association Cygnus OB2 (VI Cygni), including some foreground stars and three infrared sources. We present colour-colour and colour-magnitude diagrams from which we derive the interstellar extinction and approximate spectral types. We confirm that the interstellar extinction law in the direction of Cyg OB2 is similar to the galactic mean. (author)

  17. Small Field of View Scintimammography Gamma Camera Integrated to a Stereotactic Core Biopsy Digital X-ray System

    Energy Technology Data Exchange (ETDEWEB)

    Andrew Weisenberger; Fernando Barbosa; T. D. Green; R. Hoefer; Cynthia Keppel; Brian Kross; Stanislaw Majewski; Vladimir Popov; Randolph Wojcik

    2002-10-01

    A small field of view gamma camera has been developed for integration with a commercial stereotactic core biopsy system. The goal is to develop and implement a dual-modality imaging system utilizing scintimammography and digital radiography to evaluate the reliability of scintimammography in predicting the malignancy of suspected breast lesions from conventional X-ray mammography. The scintimammography gamma camera is a custom-built mini gamma camera with an active area of 5.3 cm /spl times/ 5.3 cm and is based on a 2 /spl times/ 2 array of Hamamatsu R7600-C8 position-sensitive photomultiplier tubes. The spatial resolution of the gamma camera at the collimator surface is < 4 mm full-width at half-maximum and a sensitivity of /spl sim/ 4000 Hz/mCi. The system is also capable of acquiring dynamic scintimammographic data to allow for dynamic uptake studies. Sample images of preliminary clinical results are presented to demonstrate the performance of the system.

  18. Cordyceps militaris alleviates non-alcoholic fatty liver disease in ob/ob mice.

    Science.gov (United States)

    Choi, Ha-Neul; Jang, Yang-Hee; Kim, Min-Joo; Seo, Min Jeong; Kang, Byoung Won; Jeong, Yong Kee; Kim, Jung-In

    2014-04-01

    Non-alcoholic fatty liver disease (NAFLD) is becoming an important public health problem as metabolic syndrome and type 2 diabetes have become epidemic. In this study we investigated the protective effect of Cordyceps militaris (C. militaris) against NAFLD in an obese mouse model. Four-week-old male ob/ob mice were fed an AIN-93G diet or a diet containing 1% C. militaris water extract for 10 weeks after 1 week of adaptation. Serum glucose, insulin, free fatty acid (FFA), alanine transaminase (ALT), and proinflammatory cytokines were measured. Hepatic levels of lipids, glutathione (GSH), and lipid peroxide were determined. Consumption of C. militaris significantly decreased serum glucose, as well as homeostasis model assessment for insulin resistance (HOMA-IR), in ob/ob mice. In addition to lowering serum FFA levels, C. militaris also significantly decreased hepatic total lipids and triglyceride contents. Serum ALT activities and tumor necrosis factor-α (TNF-α) and interleukin-6 (IL-6) levels were reduced by C. militaris. Consumption of C. militaris increased hepatic GSH and reduced lipid peroxide levels. These results indicate that C. militaris can exert protective effects against development of NAFLD, partly by reducing inflammatory cytokines and improving hepatic antioxidant status in ob/ob mice.

  19. Robot-assisted biopsies in a high-field MRI system. First clinical results; Roboterunterstuetzte Punktion in einem Hochfeld-Kernspintomografen. Erste klinische Ergebnisse

    Energy Technology Data Exchange (ETDEWEB)

    Schell, B.; Eichler, K.; Mack, M.G.; Mueller, C.; Kerl, J.M.; Beeres, M.; Thalhammer, A.; Vogl, T.J.; Zangos, S. [Frankfurt Univ. (Germany). Inst. fuer Diagnostische und Interventionelle Radiologie; Czerny, C. [Frankfurt Univ. (Germany). Inst. fuer Unfall-, Hand- und Wiederherstellungschirurgie

    2012-01-15

    Purpose: The purpose of this study was to examine the clinical use of MR-guided biopsies in patients with suspicious lesions using a new MR-compatible assistance system in a high-field MR system. Materials and Methods: Six patients with suspicious focal lesions in various anatomic regions underwent percutanous biopsy in a high-field MR system (1.5 T, Magnetom Espree, Siemens) using a new MR-compatible assistance system (Innomotion). The procedures were planned and guided using T1-weighted FLASH and TrueFISP sequences. A servopneumatic drive then moved the guiding arm automatically to the insertion point. An MRI compatible 15G biopsy system (Somatex) was introduced by a physician guided by the needle holder and multiple biopsies were performed using the coaxial technique. The feasibility, duration of the intervention and biopsy findings were analyzed. Results: The proposed new system allows accurate punctures in a high-field MR system. The assistance device did not interfere with the image quality, and guided the needle virtually exactly as planned. Histological examination could be conducted on every patient. The lesion was malignant in four cases, and an infectious etiology was diagnosed for the two remaining lesions. Regarding the differentiation of anatomical and pathological structures and position monitoring of the insertion needle, TrueFISP images are to be given preference. The average intervention time was 41 minutes. Lesions up to 15.4 cm beneath the skin surface were punctured. Conclusion: The proposed MR-guided assistance system can be successfully utilized in a high-field MR system for accurate punctures of even deep lesions in various anatomic regions. (orig.)

  20. Deflection routing scheme for GMPLS-based OBS networks

    DEFF Research Database (Denmark)

    Eid, Arafat; Mahmood, Waqar; Alomar, Anwar

    2010-01-01

    Integrating the Generalized Multi-Protocol Label Switching (GMPLS) framework into an Optical Burst Switching (OBS) Control Plane is a promising solution to alleviating most of OBS performance and design issues. However, implementing the already proposed OBS deflection routing schemes is not appli...

  1. EPR Structural Investigations on Ag2O-B2O3-CaO-P2O5 Vitreous System

    Directory of Open Access Journals (Sweden)

    Razvan Stefan

    2011-10-01

    Full Text Available Glass samples from vitreous system 1.5Ag2O98.5%[0.47B2O3(0.53-xCaOxP2O5] with 0  x  0.08 have been obtained by undercooled method. The magnetic species existing in glass powders have been highlighting by mean of electronic paramagnetic resonance (EPR. The resonance linewidth analysis reveal the interactions between magnetic ions.

  2. A synoptic reporting system for bone marrow aspiration and core biopsy specimens.

    Science.gov (United States)

    Murari, Manjula; Pandey, Rakesh

    2006-12-01

    Advances in information technology have made electronic systems productive tools for pathology report generation. Structured data formats are recommended for better understanding of pathology reports by clinicians and for retrieval of pathology reports. Suitable formats need to be developed to include structured data elements for report generation in electronic systems. To conform to the requirement of protocol-based reporting and to provide uniform and standardized data entry and retrieval, we developed a synoptic reporting system for generation of bone marrow cytology and histology reports for incorporation into our hospital information system. A combination of macro text, short preformatted templates of tabular data entry sheets, and canned files was developed using a text editor enabling protocol-based input. The system is flexible and has facility for appending free text entry. It also incorporates SNOMED coding and codes for teaching, research, and internal auditing. This synoptic reporting system is easy to use and adaptable. Features and advantages include pick-up text with defined choices, flexibility for appending free text, facility for data entry for protocol-based reports for research use, standardized and uniform format of reporting, comparable follow-up reports, minimized typographical and transcription errors, and saving on reporting time, thus helping shorten the turnaround time. Simple structured pathology report templates are a powerful means for supporting uniformity in reporting as well as subsequent data viewing and extraction, particularly suitable to computerized reporting.

  3. MR-guided biopsies

    International Nuclear Information System (INIS)

    Gehl, H.B.; Frahm, C.

    1998-01-01

    Biopsies were the first 'intervention' under MR guidance. After initial difficulties concerning ferromagnetic biopsy instruments and the design of MR scanners, the latest technological improvements rendered MR guidance for biopsies more feasible. In this article we illustrate present-day clinical experience in the field of abdominal, breast and bone biopsy. Important aspects regarding the different designs of 'interventional' MR scanners and the visualization of instruments for biopsy are discussed. (orig.) [de

  4. Origins of Discrepancies Between Kinetic Rate Law Theory and Experiments in the Na2O-B2O3-SiO2 System

    International Nuclear Information System (INIS)

    McGrail, B. PETER; Icenhower, Jonathan P.; Rodriguez, Elsa A.; McGrail, B.P.; Cragnolino, G.A.

    2002-01-01

    Discrepancies between classical kinetic rate law theory and experiment were quantitatively assessed and found to correlate with macromolecular amorphous separation in the sodium borosilicate glass system. A quantitative reinterpretation of static corrosion data and new SPFT data shows that a recently advanced protective surface layer theory fails to describe the observed dissolution behavior of simple and complex silicate glasses under carefully controlled experimental conditions. The hypothesis is shown to be self-inconsistent in contrast with a phase separation model that is in quantitative agreement with experiments

  5. Alpha-1 adrenoceptors in brown adipose tissue of lean and ob/ob mice

    International Nuclear Information System (INIS)

    Behrens-Zaror, G.; Himms-Hagen, J.

    1986-01-01

    Obese (ob/ob) mice have a low capacity to increase thyroxine 5'-deiodinase (T4 5'-D) in brown adipose tissue (BAT) when exposed to cold. This effect is mediated by alpha-1 (A-1) adrenoceptors. The authors objective was to find out whether BAT of the ob/ob mouse has normal A-1 receptors. Saturation analysis of binding of [3H]-WB4101 at 0.05 nM to 10 μM to crude membrane preparations (100,000 g pellets from Polytron homogenates) using the LIGAND program of Munson and Rodbard, showed two populations of binding sites in BAT of lean (+/+, 11-15 wk old) mice. Acute exposure (12 h, 14 0 C) or acclimation to cold (3 wk, 14 0 C) did not alter affinity or concentration of sites. Displacement with yohimbine and prazosin indicated binding of WB4101 to A-1 receptors. Very young (5 wk) lean (+/.) and obese mice had similar affinity constants (lean 0.13 +/- 0.043 and 34.2 +/- 14.9; obese, 0.12 +/- 0.028 and 20.9 +/- 5.48 nM) and concentrations (lean 22.4 +/- 3.8 and 647 +/- 137; obese, 28.6 +/- 4.6 and 547 +/- 105 fmol/mg protein) of sites. Old (1 yr) mice had high affinity sites similar to those in younger animals (KD lean 0.19 +/- 0.028, obese, 0.25 +/- 0.075; Bmax lean, 60.2 +/- 12.1; obese, 63.1 +/- 13.5 fmol/mg protein). The authors conclude that the ob/ob mouse has normal high affinity A-1 receptors in BAT. Anomalous properties of low affinity binding in old ob/ob mice could not be characterized because of high nonspecific binding. BAT of the ob/ob mouse does not lack A-1 receptors but may have a post-receptor alteration in the A-1 adrenoceptor-mediated response

  6. Design and characterization of Stormram 4 : an MRI-compatible robotic system for breast biopsy

    NARCIS (Netherlands)

    Groenhuis, Vincent; Siepel, Françoise Jeanette; Veltman, Jeroen; Stramigioli, Stefano

    2017-01-01

    Targeting of small lesions with high precision is essential in an early phase of breast cancer for diagnosis and accurate follow up, and subsequently determines prognosis. Current techniques to diagnose breast cancer are suboptimal, and there is a need for a small, MRI-compatible robotic system able

  7. Percutaneous Management of Accidentally Retained Foreign Bodies During Image-Guided Non-vascular Procedures: Novel Technique Using a Large-Bore Biopsy System

    Energy Technology Data Exchange (ETDEWEB)

    Cazzato, Roberto Luigi, E-mail: gigicazzato@hotmail.it; Garnon, Julien, E-mail: juleiengarnon@gmail.com [Hôpitaux Universitaires de Strasbourg, HUS, Department of Interventional Radiology, Nouvel Hôpital Civil (France); Ramamurthy, Nitin, E-mail: nitin-ramamurthy@hotmail.com [Norfolk and Norwich University Hospital, Department of Radiology (United Kingdom); Tsoumakidou, Georgia, E-mail: georgia.tsoumakidou@chru-strasbourg.fr; Caudrelier, Jean, E-mail: jean.caudrelier@chru-strasbourg.fr; Thénint, Marie-Aude, E-mail: marie-aude.thenint@chru-strasbourg.fr; Rao, Pramod, E-mail: pramodrao@me.com; Koch, Guillaume, E-mail: guillaume.koch@chru-strasbourg.fr; Gangi, Afshin, E-mail: gangi@unistra.fr [Hôpitaux Universitaires de Strasbourg, HUS, Department of Interventional Radiology, Nouvel Hôpital Civil (France)

    2016-07-15

    ObjectiveTo describe a novel percutaneous image-guided technique using a large-bore biopsy system to retrieve foreign bodies (FBs) accidentally retained during non-vascular interventional procedures.Materials and MethodsBetween May 2013 and October 2015, five patients underwent percutaneous retrieval of five iatrogenic FBs, including a biopsy needle tip in the femoral head following osteoblastoma biopsy and radiofrequency ablation (RFA); a co-axial needle shaft within a giant desmoid tumour following cryoablation; and three post-vertebroplasty cement tails within paraspinal muscles. All FBs were retrieved immediately following original procedures under local or general anaesthesia, using combined computed tomography (CT) and fluoroscopic guidance. The basic technique involved positioning a 6G trocar sleeve around the FB long axis and co-axially advancing an 8G biopsy needle to retrieve the FB within the biopsy core. Retrospective chart review facilitated analysis of procedures, FBs, technical success, and complications.ResultsMean FB size was 23 mm (range 8–74 mm). Four FBs were located within 10 mm of non-vascular significant anatomic structures. The basic technique was successful in 3 cases; 2 cases required technical modifications including using a stiff guide-wire to facilitate retrieval in the case of the post-cryoablation FB; and using the central mandrin of the 6G trocar to push a cement tract back into an augmented vertebra when initial retrieval failed. Overall technical success (FB retrieval or removal to non-hazardous location) was 100 %, with no complications.ConclusionPercutaneous image-guided retrieval of iatrogenic FBs using a large-bore biopsy system is a feasible, safe, effective, and versatile technique, with potential advantages over existing methods.

  8. Expression of the P2X2 receptor in different classes of ileum myenteric neurons in the female obese ob/ob mouse

    Science.gov (United States)

    Mizuno, Márcia Sanae; Crisma, Amanda Rabello; Borelli, Primavera; Castelucci, Patricia

    2012-01-01

    AIM: To examine whether the ob/ob mouse model of obesity is accompanied by enteric nervous system abnormalities such as altered motility. METHODS: The study examined the distribution of the P2X2 receptor (P2X2R) in myenteric neurons of female ob/ob mice. Specifically, we used immunohistochemistry to analyze the co-expression of the P2X2R with neuronal nitric oxide synthase (nNOS), choline acetyltransferase (ChAT), and calretinin (CalR) in neurons of the small intestine myenteric plexus in ob/ob and control female mice. In these sections, we used scanning confocal microscopy to analyze the co-localization of these markers as well as the neuronal density (cm2) and area profile (μm²) of P2X2R-positive neurons. In addition, enteric neurons were labeled using the nicotinamide adenine dinucleotide (NADH) diaphorase method and analyzed with light microscopy as an alternate means by which to analyze neuronal density and area. RESULTS: In the present study, we observed a 29.6% increase in the body weight of the ob/ob animals (OG) compared to the control group (CG). In addition, the average small intestine area was increased by approximately 29.6% in the OG compared to the CG. Immunoreactivity (IR) for the P2X2R, nNOS, ChAT and CalR was detectable in the myenteric plexus, as well as in the smooth muscle, in both groups. This IR appeared to be mainly cytoplasmic and was also associated with the cell membrane of the myenteric plexus neurons, where it outlined the neuronal cell bodies and their processes. P2X2R-IR was observed to co-localize 100% with that for nNOS, ChAT and CalR in neurons of both groups. In the ob/ob group, however, we observed that the neuronal density (neuron/cm2) of P2X2R-IR cells was increased by 62% compared to CG, while that of NOS-IR and ChAT-IR neurons was reduced by 49% and 57%, respectively, compared to control mice. The neuronal density of CalR-IR neurons was not different between the groups. Morphometric studies further demonstrated that the

  9. Deposition of plutonium isotopes and Cs-137 in sediments of the Ob delta from the beginning of the nuclear age

    International Nuclear Information System (INIS)

    Panteleyev, G.P.; Livingston, H.D.; Sayles, F.L.; Medkova, O.N.

    1995-01-01

    As an approach to an assessment of the transport of artificial radionuclides through the Ob river system towards the arctic Ocean, results are presented from the analyses of a series of sediment cores collected in the Ob delta and estuary in 1994. These cores, collected in areas of sediment accumulation, contain the depositional history at the Ob mouth of substances associated with sediment particles from the whole river system watershed. Several approaches to dating these sediments permitted the development of a chronology for the deposition of plutonium isotopes and Cs-137, following their first introduction to the environment a half century ago. Some preliminary results for I-129 are also presented. 6 figs

  10. Arctigenin, a natural compound, activates AMP-activated protein kinase via inhibition of mitochondria complex I and ameliorates metabolic disorders in ob/ob mice.

    Science.gov (United States)

    Huang, S-L; Yu, R-T; Gong, J; Feng, Y; Dai, Y-L; Hu, F; Hu, Y-H; Tao, Y-D; Leng, Y

    2012-05-01

    Arctigenin is a natural compound that had never been previously demonstrated to have a glucose-lowering effect. Here it was found to activate AMP-activated protein kinase (AMPK), and the mechanism by which this occurred, as well as the effects on glucose and lipid metabolism were investigated. 2-Deoxyglucose uptake and AMPK phosphorylation were examined in L6 myotubes and isolated skeletal muscle. Gluconeogenesis and lipid synthesis were evaluated in rat primary hepatocytes. The acute and chronic effects of arctigenin on metabolic abnormalities were observed in C57BL/6J and ob/ob mice. Changes in mitochondrial membrane potential were measured using the J-aggregate-forming dye, JC-1. Analysis of respiration of L6 myotubes or isolated mitochondria was conducted in a channel oxygen system. Arctigenin increased AMPK phosphorylation and stimulated glucose uptake in L6 myotubes and isolated skeletal muscles. In primary hepatocytes, it decreased gluconeogenesis and lipid synthesis. The enhancement of glucose uptake and suppression of hepatic gluconeogenesis and lipid synthesis by arctigenin were prevented by blockade of AMPK activation. The respiration of L6 myotubes or isolated mitochondria was inhibited by arctigenin with a specific effect on respiratory complex I. A single oral dose of arctigenin reduced gluconeogenesis in C57BL/6J mice. Chronic oral administration of arctigenin lowered blood glucose and improved lipid metabolism in ob/ob mice. This study demonstrates a new role for arctigenin as a potent indirect activator of AMPK via inhibition of respiratory complex I, with beneficial effects on metabolic disorders in ob/ob mice. This highlights the potential value of arctigenin as a possible treatment of type 2 diabetes.

  11. Diagnosis and typing of systemic amyloidosis: The role of abdominal fat pad fine needle aspiration biopsy

    Directory of Open Access Journals (Sweden)

    Halloush Ruba

    2009-01-01

    Full Text Available Introduction: Systemic amyloidosis (SA has a broad nonspecific clinical presentation. Its diagnosis depends on identifying amyloid in tissues. Abdominal fat pad fine needle aspiration (FPFNA has been suggested as a sensitive and specific test for diagnosing SA. Materials and Methods: Thirty-nine FPFNA from 38 patients (16 women and 20 men, age range 40-88 years during a 15-year period were reviewed. Smears and cell blocks were stained with Congo red (CR. A panel of antibodies (serum amyloid protein, serum amyloid A, albumin, transthyretin, kappa light chain and lambda light chain was used on six cell blocks from five patients. The FNA findings were correlated with clinical and histological follow-up. Results: FPFNAs were positive, confirmed by CR in 5/39 (13%, suspicious in 1/39 (3%, negative in 28/39 (72%, and insufficient for diagnosis in 5/39 (13% of cases. In all the positive cases, SA was confirmed within 2-16 weeks. Among the 28 negative cases, SA was diagnosed in 21, the rest were lost to follow-up. Among the insufficient cases, SA was diagnosed in four and one was lost to follow-up. Specificity was 100%, whereas sensitivity was 19%. SA typing using cell block sections was successful in three, un-interpretable in one, and negative in two cases. Conclusion: FPFNA for SA is not as good as previously reported. This may be due to different practice setting, level of experience, diagnostic technique, or absence of abdominal soft tissue involvement. A negative result of FPFNA does not exclude SA. Immune phenotyping of amyloid is possible on cell block.

  12. Diagnosis and typing of systemic amyloidosis: The role of abdominal fat pad fine needle aspiration biopsy.

    Science.gov (United States)

    Halloush, Ruba A; Lavrovskaya, Elena; Mody, Dina R; Lager, Donna; Truong, Luan

    2010-01-15

    Systemic amyloidosis (SA) has a broad nonspecific clinical presentation. Its diagnosis depends on identifying amyloid in tissues. Abdominal fat pad fine needle aspiration (FPFNA) has been suggested as a sensitive and specific test for diagnosing SA. Thirty-nine FPFNA from 38 patients (16 women and 20 men, age range 40-88 years) during a 15-year period were reviewed. Smears and cell blocks were stained with Congo red (CR). A panel of antibodies (serum amyloid protein, serum amyloid A, albumin, transthyretin, kappa light chain and lambda light chain) was used on six cell blocks from five patients. The FNA findings were correlated with clinical and histological follow-up. FPFNAs were positive, confirmed by CR in 5/39 (13%), suspicious in 1/39 (3%), negative in 28/39 (72%), and insufficient for diagnosis in 5/39 (13%) of cases. In all the positive cases, SA was confirmed within 2-16 weeks. Among the 28 negative cases, SA was diagnosed in 21, the rest were lost to follow-up. Among the insufficient cases, SA was diagnosed in four and one was lost to follow-up. Specificity was 100%, whereas sensitivity was 19%. SA typing using cell block sections was successful in three, un-interpretable in one, and negative in two cases. FPFNA for SA is not as good as previously reported. This may be due to different practice setting, level of experience, diagnostic technique, or absence of abdominal soft tissue involvement. A negative result of FPFNA does not exclude SA. Immune phenotyping of amyloid is possible on cell block.

  13. Determining OBS Instrument Orientations: A Comparison of Algorithms

    Science.gov (United States)

    Doran, A. K.; Laske, G.

    2015-12-01

    The alignment of the orientation of the horizontal seismometer components with the geographical coordinate system is critical for a wide variety of seismic analyses, but the traditional deployment method of ocean bottom seismometers (OBS) precludes knowledge of this parameter. Current techniques for determining the orientation predominantly rely on body and surface wave data recorded from teleseismic events with sufficiently large magnitudes. Both wave types experience lateral refraction between the source and receiver as a result of heterogeneity and anisotropy, and therefore the arrival angle of any one phase can significantly deviate from the great circle minor arc. We systematically compare the results and uncertainties obtained through current determination methods, as well as describe a new algorithm that uses body wave, surface wave, and differential pressure gauge data (where available) to invert for horizontal orientation. To start with, our method is based on the easily transportable computer code of Stachnik et al. (2012) that is publicly available through IRIS. A major addition is that we utilize updated global dispersion maps to account for lateral refraction, as was done by Laske (1995). We also make measurements in a wide range of frequencies, and analyze surface wave trains of repeat orbits. Our method has the advantage of requiring fewer total events to achieve high precision estimates, which is beneficial for OBS deployments that can be as short as weeks. Although the program is designed for the purpose of use with OBS instruments, it also works with standard land installations. We intend to provide the community with a program that is easy to use, requires minimal user input, and is optimized to work with data cataloged at the IRIS DMC.

  14. Search for OB stars running away from young star clusters. I. NGC 6611

    Science.gov (United States)

    Gvaramadze, V. V.; Bomans, D. J.

    2008-11-01

    N-body simulations have shown that the dynamical decay of the young (~1 Myr) Orion Nebula cluster could be responsible for the loss of at least half of its initial content of OB stars. This result suggests that other young stellar systems could also lose a significant fraction of their massive stars at the very beginning of their evolution. To confirm this expectation, we used the Mid-Infrared Galactic Plane Survey (completed by the Midcourse Space Experiment satellite) to search for bow shocks around a number of young (⪉several Myr) clusters and OB associations. We discovered dozens of bow shocks generated by OB stars running away from these stellar systems, supporting the idea of significant dynamical loss of OB stars. In this paper, we report the discovery of three bow shocks produced by O-type stars ejected from the open cluster NGC 6611 (M16). One of the bow shocks is associated with the O9.5Iab star HD165319, which was suggested to be one of “the best examples for isolated Galactic high-mass star formation” (de Wit et al. 2005, A&A, 437, 247). Possible implications of our results for the origin of field OB stars are discussed.

  15. The Orientation of Gastric Biopsy Samples Improves the Inter-observer Agreement of the OLGA Staging System.

    Science.gov (United States)

    Cotruta, Bogdan; Gheorghe, Cristian; Iacob, Razvan; Dumbrava, Mona; Radu, Cristina; Bancila, Ion; Becheanu, Gabriel

    2017-12-01

    Evaluation of severity and extension of gastric atrophy and intestinal metaplasia is recommended to identify subjects with a high risk for gastric cancer. The inter-observer agreement for the assessment of gastric atrophy is reported to be low. The aim of the study was to evaluate the inter-observer agreement for the assessment of severity and extension of gastric atrophy using oriented and unoriented gastric biopsy samples. Furthermore, the quality of biopsy specimens in oriented and unoriented samples was analyzed. A total of 35 subjects with dyspeptic symptoms addressed for gastrointestinal endoscopy that agreed to enter the study were prospectively enrolled. The OLGA/OLGIM gastric biopsies protocol was used. From each subject two sets of biopsies were obtained (four from the antrum, two oriented and two unoriented, two from the gastric incisure, one oriented and one unoriented, four from the gastric body, two oriented and two unoriented). The orientation of the biopsy samples was completed using nitrocellulose filters (Endokit®, BioOptica, Milan, Italy). The samples were blindly examined by two experienced pathologists. Inter-observer agreement was evaluated using kappa statistic for inter-rater agreement. The quality of histopathology specimens taking into account the identification of lamina propria was analyzed in oriented vs. unoriented samples. The samples with detectable lamina propria mucosae were defined as good quality specimens. Categorical data was analyzed using chi-square test and a two-sided p value <0.05 was considered statistically significant. A total of 350 biopsy samples were analyzed (175 oriented / 175 unoriented). The kappa index values for oriented/unoriented OLGA 0/I/II/III and IV stages have been 0.62/0.13, 0.70/0.20, 0.61/0.06, 0.62/0.46, and 0.77/0.50, respectively. For OLGIM 0/I/II/III stages the kappa index values for oriented/unoriented samples were 0.83/0.83, 0.88/0.89, 0.70/0.88 and 0.83/1, respectively. No case of OLGIM IV

  16. Salivary gland biopsy

    Science.gov (United States)

    ... also be performed to diagnose diseases such as Sjogren syndrome . How to Prepare for the Test There is ... few days after the biopsy. The biopsy for Sjogren syndrome requires an injection of the anesthetic in the ...

  17. Cordyceps militaris alleviates non-alcoholic fatty liver disease in ob/ob mice

    OpenAIRE

    Choi, Ha-Neul; Jang, Yang-Hee; Kim, Min-Joo; Seo, Min Jeong; Kang, Byoung Won; Jeong, Yong Kee; Kim, Jung-In

    2014-01-01

    BACKGROUND/OBJECTIVES Non-alcoholic fatty liver disease (NAFLD) is becoming an important public health problem as metabolic syndrome and type 2 diabetes have become epidemic. In this study we investigated the protective effect of Cordyceps militaris (C. militaris) against NAFLD in an obese mouse model. MATERIALS/METHODS Four-week-old male ob/ob mice were fed an AIN-93G diet or a diet containing 1% C. militaris water extract for 10 weeks after 1 week of adaptation. Serum glucose, insulin, free...

  18. Breast cancer with Her-22 hormone receptor-positive neu: primary systemic treatment, sentinel node biopsy and hormone

    International Nuclear Information System (INIS)

    Lopez C, Nayara; Sanchez M, Jose Ignacio; De Santiago G, Javier

    2013-01-01

    Neoadjuvant chemotherapy is an interesting option in the therapy of some breast cancer cases. Cases in which the timing for sentinel lymph node biopsy is controversial. Co-expression of estrogen receptors and Her2/neu (cc-erbB-2) in breast cancer may imply hormone resistance, especially to tamoxifen. We present a clinic case with co-expression of estrogen receptors and Her2/neu that was treated with neoadjuvant chemotherapy and previous sentinel lymph node biopsy followed by breast tumorectomy with axillar lympha- denectomy, radiotherapy and hormonotherapy with letrozol, geserelina and trastuzumab. A good treatment response as found

  19. Can Prostate Imaging Reporting and Data System Version 2 reduce unnecessary prostate biopsies in men with PSA levels of 4-10 ng/ml?

    Science.gov (United States)

    Xu, Ning; Wu, Yu-Peng; Chen, Dong-Ning; Ke, Zhi-Bin; Cai, Hai; Wei, Yong; Zheng, Qing-Shui; Huang, Jin-Bei; Li, Xiao-Dong; Xue, Xue-Yi

    2018-05-01

    To explore the value of Prostate Imaging Reporting and Data System Version 2 (PI-RADS v2) for predicting prostate biopsy results in patients with prostate specific antigen (PSA) levels of 4-10 ng/ml. We retrospectively reviewed multi-parameter magnetic resonance images from 528 patients with PSA levels of 4-10 ng/ml who underwent transrectal ultrasound-guided prostate biopsies between May 2015 and May 2017. Among them, 137 were diagnosed with prostate cancer (PCa), and we further subdivided them according to pathological results into the significant PCa (S-PCa) and insignificant significant PCa (Ins-PCa) groups (121 cases were defined by surgical pathological specimen and 16 by biopsy). Age, PSA, percent free PSA, PSA density (PSAD), prostate volume (PV), and PI-RADS score were collected. Logistic regression analysis was performed to determine predictors of pathological results. Receiver operating characteristic curves were constructed to analyze the diagnostic value of PI-RADS v2 in PCa. Multivariate analysis indicated that age, PV, percent free PSA, and PI-RADS score were independent predictors of biopsy findings, while only PI-RADS score was an independent predictor of S-PCa (P PSA, and PI-RADS score were 0.570, 0.430, 0.589 and 0.836, respectively. The area under the curve for diagnosing S-PCa with respect to PI-RADS score was 0.732. A PI-RADS score of 3 was the best cutoff for predicting PCa, and 4 was the best cutoff for predicting S-PCa. Thus, 92.8% of patients with PI-RADS scores of 1-2 would have avoided biopsy, but at the cost of missing 2.2% of the potential PCa cases. Similarly, 83.82% of patients with a PI-RADS score ≤ 3 would have avoided biopsy, but at the cost of missing 3.3% of the potential S-PCa cases. PI-RADS v2 could be used to reduce unnecessary prostate biopsies in patients with PSA levels of 4-10 ng/ml.

  20. Automated identification of OB associations in M31

    Science.gov (United States)

    Magnier, Eugene A.; Battinelli, Paolo; Lewin, Walter H. G.; Haiman, Zoltan; Paradijs, Jan Van; Hasinger, Guenther; Pietsch, Wolfgang; Supper, Rodrigo; Truemper, Joachim

    1993-01-01

    A new identification of OB associations in M31 has been performed using the Path Linkage Criterion (PLC) technique of Battinelli (1991). We found 174 associations with a very small contamination (less than 5%) by random clumps of stars. The expected total number and average size of OB associations in the region of M 31 covered by our data set (Magnier et al. 1992) are approximately 280 and approximately 90 pc, respectively. M31 associations therefore have sizes similar to those of OB associations observed in nearby galaxies, so that we can consider them to be classical OB associations. This list of OB associations will be used for the study of the spatial distribution of OB associations and their correlation with other objects. Taking into account the fact that we do not cover the entire disk of M31, we extrapolate a total number of association in M31 of approximately 420.

  1. ESTIMATION OF BURSTS LENGTH AND DESIGN OF A FIBER DELAY LINE BASED OBS ROUTER

    Directory of Open Access Journals (Sweden)

    RICHA AWASTHI

    2017-03-01

    Full Text Available The demand for higher bandwidth is increasing day by day and this ever growing demand cannot be catered to with current electronic technology. Thus new communication technology like optical communication needs to be used. In the similar context OBS (optical burst switching is considered as next generation data transfer technology. In OBS information is transmitted in forms of optical bursts of variable lengths. However, contention among the bursts is a major problem in OBS system, and for contention resolution defection routing is mostly preferred. However, deflection routing increases delay. In this paper, it is shown that the arrival of very large bursts is rare event, and for moderate burst length the buffering of contending burst can provide very effective solution. However, in case of arrival of large bursts deflection can be used.

  2. MRI-guided trephine biopsy and fine-needle aspiration in the diagnosis of bone lesions in low-field (0.23 T) MRI system using optical instrument tracking

    International Nuclear Information System (INIS)

    Blanco Sequeiros, Roberto; Klemola, Rauli; Ojala, Risto; Jyrkinen, Lasse; Tervonen, Osmo; Lappi-Blanco, Elisa; Soini, Ylermi

    2002-01-01

    The purpose of this study was to evaluate the feasibility of MRI-guided bone biopsy with optical instrument tracking and evaluate advantage of combined fine-needle aspiration (FNA) with trephine biopsy. Twenty trephine bone biopsies and 13 FNAs were performed under MRI and CT guidance in 14 patients. Informed consent was obtained from all patients. The evaluation of diagnostic accuracy was achieved by comparing the histopathological and cytological diagnosis with current or final diagnosis made during 6-month clinical follow-up. A 0.23-T open MRI scanner with interventional tools (Outlook Proview, Marconi Medical Systems, Cleveland, Ohio) was used. A surface coil was used. For trephine biopsy MRI-compatible bone biopsy set (Daum medical, Schwerin, Germany) was used. The FNA was performed with MRI compatible 20-G needle (Cook, Bloomington, Ind.). The diagnostic accuracy of MRI-guided trephine biopsy was 95%. The FNA sample diagnosis concurred with the histological in 54%. Our results show that MRI guidance in bone biopsies is accurate and safe. It is comparable to CT-guided or open biopsy. The role of combined FNA with bone biopsies remains controversial. (orig.)

  3. COMP-angiopoietin-1 recovers molecular biomarkers of neuropathy and improves vascularisation in sciatic nerve of ob/ob mice.

    Directory of Open Access Journals (Sweden)

    Joanna Kosacka

    Full Text Available BACKGROUND: Leptin-deficient ob/ob mice are a model of type 2 diabetes induced peripheral neuropathy. Ob/ob mice exhibit obesity, insulin resistance, hyperglycaemia, and alterations of peripheral nerve fibres and endoneural microvessels. Here we test the hypothesis that cartilage oligomeric matrix protein (COMP-Ang-1, a soluble and stabile form of Ang-1 which promotes angiogenesis and nerve growth, improves regeneration of nerve fibres and endoneural microvessels in ob/ob mice. METHODS AND FINDINGS: COMP-Ang-1 (100 ng/ml or NaCl were intraperitoneally (i.p. injected into male (N = 184, 3-month old, ob/ob or ob/+ mice for 7 and 21 days. We measured expression of Nf68, GAP43, Cx32, Cx26, Cx43, and TNFα in sciatic nerves using Western blot analysis. To investigate the inflammation in sciatic nerves, numbers of macrophages and T-cells were counted after immunofluorescence staining. In ultrathin section, number of myelinated/non-mylinated nerve fibers, g-ratio, the thickness of Schwann cell basal lamina and microvessel endothelium were investigated. Endoneural microvessels were reconstructed with intracardial FITC injection. Treatment with COMP-Ang-1 over 21 days significantly reduced fasting blood glucose and plasma cholesterol concentrations compared to saline treated ob/ob mice. In addition, COMP-Ang-1 treatment: 1 up-regulated expression of Nf68 and GAP43; 2 improved expression of gap junction proteins including connexin 32 and 26; 3 suppressed the expression of TNFα and Cx43 and 4 led to decreased macrophage and T-cell infiltration in sciatic nerve of ob/ob mice. The significant changes of sciatic nerve ultrastructure were not observed after 21-day long COMP-Ang-1 treatment. COMP-Ang-1 treated ob/ob mice displayed regeneration of small-diameter endoneural microvessels. Effects of COMP-Ang-1 corresponded to increased phosphorylation of Akt and p38 MAPK upon Tie-2 receptor. CONCLUSIONS: COMP-Ang-1 recovers molecular biomarkers of neuropathy

  4. Abdominal wall fat pad biopsy

    Science.gov (United States)

    Amyloidosis - abdominal wall fat pad biopsy; Abdominal wall biopsy; Biopsy - abdominal wall fat pad ... is the most common method of taking an abdominal wall fat pad biopsy . The health care provider cleans the ...

  5. Case report of a 28-year-old male with the rapid progression of steroid-resistant central nervous system vasculitis diagnosed by a brain biopsy.

    Science.gov (United States)

    Takahashi, Keigo; Sato, Hideki; Hattori, Hidenori; Takao, Masaki; Takahashi, Shinichi; Suzuki, Norihiro

    2017-09-30

    A 28-year-old Japanese male without a significant past medical history presented with new-onset generalized clonic seizure and headache. A brain MRI revealed multiple enhanced lesions on both cerebral hemispheres. Laboratory exams showed no evidence of systemic inflammation or auto-immune antibodies such as ANCAs. Despite four courses of high-dose methylprednisolone pulse therapy and five treatments with plasmapheresis, his symptoms worsened and the MRI lesions progressed rapidly. During these treatments, we performed a targeted brain biopsy, that revealed histological findings consistent with a predominant angiitis of parenchymal and subdural small vessels. He was provided with diagnosis of central nervous system vasculitis (CNSV). Subsequent cyclophosphamide pulse therapy enabled a progressive successful improvement of his symptoms. While diagnostic methods for CNSV remain controversial, histological findings are thought to be more useful in obtaining a more definitive diagnosis than findings in image studies, such as MRI and angiography. We suggest that a brain biopsy should be considered during the early period of cases with suspected CNSV and rapid clinical deterioration. We also detected human herpesvirus 7 (HHV-7) using PCR technology in brain biopsy specimens, however the relationship between CNSV and HHV-7 infection is unknow.

  6. Needle muscle biopsy and its application

    Directory of Open Access Journals (Sweden)

    Meng-long CHEN

    2015-07-01

    Full Text Available Needle muscle biopsy is a straightforward and reliable minimally-invasive technique. During the past century, the needle biopsy can provide adequate samples and the technique has gradually gained wider acceptance. Compared with open biopsy, needle biopsy is less traumatic, with low rate of complications, and is suitable for the identifications and evaluations of muscular dystrophy, inflammatory myopathies and systemic diseases involving muscles, specially for infants and young children. Domestic insiders should be encouraged to apply this technique. DOI: 10.3969/j.issn.1672-6731.2015.06.003 

  7. Targeting Accuracy, Procedure Times and User Experience of 240 Experimental MRI Biopsies Guided by a Clinical Add-On Navigation System.

    Directory of Open Access Journals (Sweden)

    Harald Busse

    Full Text Available MRI is of great clinical utility for the guidance of special diagnostic and therapeutic interventions. The majority of such procedures are performed iteratively ("in-and-out" in standard, closed-bore MRI systems with control imaging inside the bore and needle adjustments outside the bore. The fundamental limitations of such an approach have led to the development of various assistance techniques, from simple guidance tools to advanced navigation systems. The purpose of this work was to thoroughly assess the targeting accuracy, workflow and usability of a clinical add-on navigation solution on 240 simulated biopsies by different medical operators.Navigation relied on a virtual 3D MRI scene with real-time overlay of the optically tracked biopsy needle. Smart reference markers on a freely adjustable arm ensured proper registration. Twenty-four operators - attending (AR and resident radiologists (RR as well as medical students (MS - performed well-controlled biopsies of 10 embedded model targets (mean diameter: 8.5 mm, insertion depths: 17-76 mm. Targeting accuracy, procedure times and 13 Likert scores on system performance were determined (strong agreement: 5.0.Differences in diagnostic success rates (AR: 93%, RR: 88%, MS: 81% were not significant. In contrast, between-group differences in biopsy times (AR: 4:15, RR: 4:40, MS: 5:06 min:sec differed significantly (p<0.01. Mean overall rating was 4.2. The average operator would use the system again (4.8 and stated that the outcome justifies the extra effort (4.4. Lowest agreement was reported for the robustness against external perturbations (2.8.The described combination of optical tracking technology with an automatic MRI registration appears to be sufficiently accurate for instrument guidance in a standard (closed-bore MRI environment. High targeting accuracy and usability was demonstrated on a relatively large number of procedures and operators. Between groups with different expertise there were

  8. Targeting Accuracy, Procedure Times and User Experience of 240 Experimental MRI Biopsies Guided by a Clinical Add-On Navigation System.

    Science.gov (United States)

    Busse, Harald; Riedel, Tim; Garnov, Nikita; Thörmer, Gregor; Kahn, Thomas; Moche, Michael

    2015-01-01

    MRI is of great clinical utility for the guidance of special diagnostic and therapeutic interventions. The majority of such procedures are performed iteratively ("in-and-out") in standard, closed-bore MRI systems with control imaging inside the bore and needle adjustments outside the bore. The fundamental limitations of such an approach have led to the development of various assistance techniques, from simple guidance tools to advanced navigation systems. The purpose of this work was to thoroughly assess the targeting accuracy, workflow and usability of a clinical add-on navigation solution on 240 simulated biopsies by different medical operators. Navigation relied on a virtual 3D MRI scene with real-time overlay of the optically tracked biopsy needle. Smart reference markers on a freely adjustable arm ensured proper registration. Twenty-four operators - attending (AR) and resident radiologists (RR) as well as medical students (MS) - performed well-controlled biopsies of 10 embedded model targets (mean diameter: 8.5 mm, insertion depths: 17-76 mm). Targeting accuracy, procedure times and 13 Likert scores on system performance were determined (strong agreement: 5.0). Differences in diagnostic success rates (AR: 93%, RR: 88%, MS: 81%) were not significant. In contrast, between-group differences in biopsy times (AR: 4:15, RR: 4:40, MS: 5:06 min:sec) differed significantly (p<0.01). Mean overall rating was 4.2. The average operator would use the system again (4.8) and stated that the outcome justifies the extra effort (4.4). Lowest agreement was reported for the robustness against external perturbations (2.8). The described combination of optical tracking technology with an automatic MRI registration appears to be sufficiently accurate for instrument guidance in a standard (closed-bore) MRI environment. High targeting accuracy and usability was demonstrated on a relatively large number of procedures and operators. Between groups with different expertise there were

  9. La biopsie prostatique

    OpenAIRE

    DJEDOUI, MERIEM

    2013-01-01

    La preuve d'un cancer de la prostate est apportée par la biopsie prostatique. Malheureusement, une biopsie négative, bien que rassurante, ne suffit pas à exclure un noyau cancéreux à côté duquel l'aiguille est passée. L'urologue peut être amené à proposer une nouvelle biopsie, en augmentant, s'il le faut, le nombre de prélèvements de tissu prostatique. Ayant connu Le but d'une biopsie prostatique, le patient pourrait maintenant décider d'entrer dans d'autres alternatives qui...

  10. Fluoroquinolone-Resistant Escherichia coli Infections after Transrectal Biopsy of the Prostate in the Veterans Affairs Healthcare System

    Directory of Open Access Journals (Sweden)

    Elie Antoun Saade

    2016-09-01

    Full Text Available Background: Recent reports suggest that infections due to fluoroquinolone-resistant Escherichia coli (E. coli are an increasingly common complication of transrectal biopsy of the prostate (TBP in the United States. A better understanding of the magnitude and scope of these infections is needed to guide prevention efforts. Our objective is to determine whether the incidence of infections due to fluoroquinolone-resistant E. coli after TBP has increased nationwide in the Veterans Affairs Health Care System and to identify risk factors for infection. Methods: We performed a retrospective, observational cohort study and a nested case-control study within the US Deparment of Veterans Affairs Healthcare System. The primary outcomes were the incidence of urinary tract infection (UTI and bacteremia with E. coli and with fluoroquinolone-resistant E. coli strains within 30 days after TBP. Secondary endpoints focused on the correlation between fluoroquinolone-resistance in all urinary E. coli isolates and post-TBP infection and risk factors for infection due to fluoroquinolone-resistant E. coli infection. Results: 245 618 patients undergoing 302 168 TBP procedures from 2000 through 2013 were included in the cohort study, and 59 469 patients undergoing TBP from 2011 through 2013 were included in the nested case-control study. Between 2000 and 2013, there was a 5-fold increase in the incidence of E. coli UTI (0.18%–0.93% and a 4-fold increase in the incidence of E. coli bacteremia (0.04%–0.18% after TBP that was attributable to an increase in the incidence of fluoroquinolone-resistant E. coli UTI (0.03%–0.75% and bacteremia (0.01%–0.14%. The increasing incidence of fluoroquinolone-resistant E. coli infections after TBP occurred in parallel with increasing rates of fluoroquinolone-resistance in all urinary E. coli isolates. By multivariable logistic regression analysis, independent risk factors for fluoroquinolone

  11. [Skin biopsy in diagnosis of chronic graft-versus-host disease in patients after allogeneic haematopoietic stem cell transplantation: pathologist's point of view on quantitative scoring system].

    Science.gov (United States)

    Grzanka, Dariusz; Styczyński, Jan; Debski, Robert; Krenska, Anna; Pacholska, Małgorzata; Prokurat, Andrzej I; Wysocki, Mariusz; Marszałek, Andrzej

    2008-01-01

    Pathology diagnosis of chronic graft-versus-host-disease (GVHD) after allogeneic haematopoietic stem cell transplantation (allo-HSCT) is an important issue in clinical follow-up, in spite of frequent difficulties in interpretation., related to dynamic changes occurring in the skin during the disease, as well as to sequelae of basic disease and immunosuppressive therapy. Recently presented Consensus NIH (National Health Institute, Bethesda, USA) of histopathologic (HP) analysis is still complex and intrinsically divergent, thus clinically difficult to implement. Analysis of clinical value of histological evaluation results of skin biopsy in children after allo-HSCT and its correlation with clinical status. Ten skin biopsies were taken from 7 patients (4 boys, 3 girls, age 3-15 years) after allo-HSCT (6 MFD, 1 MMUD) and analyzed after hematoxylin/eosine and immunohistochemical (CD3, CD45T, CD20) staining. Pathology analysis was based on commonly accepted criteria enabling simple and unambiguous interpretation. Results were compared with clinical data and indications for immunosuppressive therapy. It was found that reliable and coherent interpretation can be made when following parameters were taken into account: 1. in epithelium: the presence of apoptosis, archetypical changes and vacuolar degeneration in the basilar layer, presence of CD3/CD45 in the epidermis; 2. in the dermis: the extent of collagenization, presence of melanophages and lymphocyte infiltrations; 3. in the eccrine glands epithelium: eccrine glands atrophy and presence of lymphocytes. A new scoring system of skin biopsy analysis in patients with chronic GVHD based on the modified NIH Consensus was proposed. The preliminary clinical value of histological results was assessed. Skin biopsy evaluation based on limited qualitative and quantitative analysis of lymphocyte infiltrates together with studies on intensity of apoptosis, collagenization and archetypical changes is a valuable diagnostic method

  12. CT-guided percutaneous lung biopsy: Comparison of conventional CT fluoroscopy to CT fluoroscopy with electromagnetic navigation system in 60 consecutive patients

    Energy Technology Data Exchange (ETDEWEB)

    Grand, David Justin, E-mail: dgrand@lifespan.org [Department of Diagnostic Imaging, Warren Alpert School of Medicine, Brown University, Providence, RI 02903 (United States); Atalay, Michael A., E-mail: matalay@lifespan.org [Department of Diagnostic Imaging, Warren Alpert School of Medicine, Brown University, Providence, RI 02903 (United States); Cronan, John J., E-mail: cronan@lifespan.org [Department of Diagnostic Imaging, Warren Alpert School of Medicine, Brown University, Providence, RI 02903 (United States); Mayo-Smith, William W., E-mail: wmayo-smith@lifespan.org [Department of Diagnostic Imaging, Warren Alpert School of Medicine, Brown University, Providence, RI 02903 (United States); Dupuy, Damian E., E-mail: ddupuy@lifespan.org [Department of Diagnostic Imaging, Warren Alpert School of Medicine, Brown University, Providence, RI 02903 (United States)

    2011-08-15

    Purpose: To determine if use of an electromagnetic navigation system (EMN) decreases radiation dose and procedure time of CT fluoroscopy guided lung biopsy in lesions smaller than 2.5 cm. Materials/methods: 86 consecutive patients with small lung masses (<2.5 cm) were approached. 60 consented and were randomized to undergo biopsy with CT fluoroscopy (CTF) (34 patients) or EMN (26 patients). Technical failure required conversion to CTF in 8/26 EMN patients; 18 patients completed biopsy with EMN. Numerous biopsy parameters were compared as described below. Results: Average fluoroscopy time using CTF was 28.2 s compared to 35.0 s for EMN (p = 0.1). Average radiation dose was 117 mGy using CTF and 123 mGy for EMN (p = 0.7). Average number of needle repositions was 3.7 for CTF and 4.4 for EMN (p = 0.4). Average procedure time was 15 min for CTF and 20 min for EMN (p = 0.01). There were 7 pneumothoracesin the CTF group and 6 pneumothoraces in the EMN group (p = 0.7). One pneumothorax in the CTF group and 3 pneumothoraces in the EMN group required chest tube placement (p = 0.1). One pneumothorax patient in each group required hospital admission. Diagnostic specimens were obtained in 31/34 patients in the CTF group and 22/26 patients in the EMN group (p = 0.4). Conclusions: EMN was not statistically different than CTF for fluoroscopy time, radiation dose, number of needle repositions, incidence of pneumothorax, need for chest tube, or diagnostic yield. Procedure time was increased with EMN.

  13. Enhanced glucose cycling and suppressed de novo synthesis of glucose-6-phosphate result in a net unchanged hepatic glucose output in ob/ob mice

    NARCIS (Netherlands)

    Bandsma, RHJ; Grefhorst, A; van Dijk, TH; van der Sluijs, FH; Hammer, A; Reijngoud, DJ; Kuipers, F

    2004-01-01

    Aims/hypothesis. Leptin-deficient ob/ob mice are hyperinsulinaemic and hyperglycaemic; however, the cause of hyperglycaemia remains largely unknown. Methods. Glucose metabolism in vivo in 9-h fasted ob/ob mice and lean littermates was studied by infusing [U-C-13]-glucose, [2-C-13]-glycerol,

  14. Advective transport observations with MODPATH-OBS--documentation of the MODPATH observation process

    Science.gov (United States)

    Hanson, R.T.; Kauffman, L.K.; Hill, M.C.; Dickinson, J.E.; Mehl, S.W.

    2013-01-01

    The MODPATH-OBS computer program described in this report is designed to calculate simulated equivalents for observations related to advective groundwater transport that can be represented in a quantitative way by using simulated particle-tracking data. The simulated equivalents supported by MODPATH-OBS are (1) distance from a source location at a defined time, or proximity to an observed location; (2) time of travel from an initial location to defined locations, areas, or volumes of the simulated system; (3) concentrations used to simulate groundwater age; and (4) percentages of water derived from contributing source areas. Although particle tracking only simulates the advective component of conservative transport, effects of non-conservative processes such as retardation can be approximated through manipulation of the effective-porosity value used to calculate velocity based on the properties of selected conservative tracers. This program can also account for simple decay or production, but it cannot account for diffusion. Dispersion can be represented through direct simulation of subsurface heterogeneity and the use of many particles. MODPATH-OBS acts as a postprocessor to MODPATH, so that the sequence of model runs generally required is MODFLOW, MODPATH, and MODPATH-OBS. The version of MODFLOW and MODPATH that support the version of MODPATH-OBS presented in this report are MODFLOW-2005 or MODFLOW-LGR, and MODPATH-LGR. MODFLOW-LGR is derived from MODFLOW-2005, MODPATH 5, and MODPATH 6 and supports local grid refinement. MODPATH-LGR is derived from MODPATH 5. It supports the forward and backward tracking of particles through locally refined grids and provides the output needed for MODPATH_OBS. For a single grid and no observations, MODPATH-LGR results are equivalent to MODPATH 5. MODPATH-LGR and MODPATH-OBS simulations can use nearly all of the capabilities of MODFLOW-2005 and MODFLOW-LGR; for example, simulations may be steady-state, transient, or a combination

  15. Leptin Increases Striatal Dopamine D2 Receptor Binding in Leptin-Deficient Obese (ob/ob) Mice

    Energy Technology Data Exchange (ETDEWEB)

    Pfaffly, J.; Michaelides, M.; Wang, G-J.; Pessin, J.E.; Volkow, N.D.; Thanos, P.K.

    2010-06-01

    Peripheral and central leptin administration have been shown to mediate central dopamine (DA) signaling. Leptin-receptor deficient rodents show decreased DA D2 receptor (D2R) binding in striatum and unique DA profiles compared to controls. Leptin-deficient mice show increased DA activity in reward-related brain regions. The objective of this study was to examine whether basal D2R-binding differences contribute to the phenotypic behaviors of leptin-deficient ob/ob mice, and whether D2R binding is altered in response to peripheral leptin treatment in these mice. Leptin decreased body weight, food intake, and plasma insulin concentration in ob/ob mice but not in wild-type mice. Basal striatal D2R binding (measured with autoradiography [{sup 3}H] spiperone) did not differ between ob/ob and wild-type mice but the response to leptin did. In wild-type mice, leptin decreased striatal D2R binding, whereas, in ob/ob mice, leptin increased D2R binding. Our findings provide further evidence that leptin modulates D2R expression in striatum and that these effects are genotype/phenotype dependent.

  16. Biopsy - Multiple Languages

    Science.gov (United States)

    ... Biopsy - العربية (Arabic) Bilingual PDF Health Information Translations Breast Biopsy - العربية (Arabic) Bilingual PDF Health Information Translations Colposcopy - العربية (Arabic) Bilingual PDF ...

  17. High rate of vaginal erosions associated with the mentor ObTape.

    Science.gov (United States)

    Yamada, Brian S; Govier, Fred E; Stefanovic, Ksenija B; Kobashi, Kathleen C

    2006-08-01

    The transobturator tape method is a newer surgical technique for the treatment of stress urinary incontinence. Limited data exist related to complications with this approach or the types of mesh products used. We report our experience with vaginal erosions associated with the Mentor ObTape and American Medical Systems Monarc transobturator slings. Beginning in December 2003 selected female patients with anatomic urinary incontinence were prospectively followed after placement of the Mentor ObTape. Beginning in January 2004 we also began using the American Medical Systems Monarc in similar patients. Patients were admitted overnight after surgery, discharged on oral antibiotics, and seen in the clinic at 6 weeks postoperatively. A total of 67 patients have undergone placement of the Mentor ObTape and 9 of those patients (13.4%) have had vaginal extrusions of the sling. Eight patients reported a history of persistent vaginal discharge. One patient presented initially to an outside facility with a left thigh abscess tracking to the left inguinal incision site. Each patient was taken back to the operating room for mesh removal. A total of 56 patients have undergone placement of the AMS Monarc and none have had any vaginal erosions. Our high rate of vaginal extrusion using the ObTape has led us to discontinue the use of this product in our institution. Continued followup of all of these patients will be of critical importance.

  18. Comparison between target magnetic resonance imaging (MRI) in-gantry and cognitively directed transperineal or transrectal-guided prostate biopsies for Prostate Imaging-Reporting and Data System (PI-RADS) 3-5 MRI lesions.

    Science.gov (United States)

    Yaxley, Anna J; Yaxley, John W; Thangasamy, Isaac A; Ballard, Emma; Pokorny, Morgan R

    2017-11-01

    To compare the detection rates of prostate cancer (PCa) in men with Prostate Imaging-Reporting and Data System (PI-RADS) 3-5 abnormalities on 3-Tesla multiparametric (mp) magnetic resonance imaging (MRI) using in-bore MRI-guided biopsy compared with cognitively directed transperineal (cTP) biopsy and transrectal ultrasonography (cTRUS) biopsy. This was a retrospective single-centre study of consecutive men attending the private practice clinic of an experienced urologist performing MRI-guided biopsy and an experienced urologist performing cTP and cTRUS biopsy techniques for PI-RADS 3-5 lesions identified on 3-Tesla mpMRI. There were 595 target mpMRI lesions from 482 men with PI-RADS 3-5 regions of interest during 483 episodes of biopsy. The abnormal mpMRI target lesion was biopsied using the MRI-guided method for 298 biopsies, the cTP method for 248 biopsies and the cTRUS method for 49 biopsies. There were no significant differences in PCa detection among the three biopsy methods in PI-RADS 3 (48.9%, 40.0% and 44.4%, respectively), PI-RADS 4 (73.2%, 81.0% and 85.0%, respectively) or PI-RADS 5 (95.2, 92.0% and 95.0%, respectively) lesions, and there was no significant difference in detection of significant PCa among the biopsy methods in PI-RADS 3 (42.2%, 30.0% and 33.3%, respectively), PI-RADS 4 (66.8%, 66.0% and 80.0%, respectively) or PI-RADS 5 (90.5%, 89.8% and 90.0%, respectively) lesions. There were also no differences in PCa or significant PCa detection based on lesion location or size among the methods. We found no significant difference in the ability to detect PCa or significant PCa using targeted MRI-guided, cTP or cTRUS biopsy methods. Identification of an abnormal area on mpMRI appears to be more important in increasing the detection of PCa than the technique used to biopsy an MRI abnormality. © 2017 The Authors BJU International © 2017 BJU International Published by John Wiley & Sons Ltd.

  19. Improved transvenous liver biopsy needle

    DEFF Research Database (Denmark)

    Henriksen, Jens Henrik Sahl; Matzen, P; Christoffersen, P

    1979-01-01

    A modified type of the standard transvenous cholangiography biopsy needle is described. The modified tranvenous liver biopsy needle caused only minimal artefactual changes of the liver biopsy specimens. The new type of biopsy needle is a modified Menghini needle. The conventional Menghini needle...... should be avoided for transvenous catheter biopsies because of risk of leaving catheter fragments in the liver....

  20. PrediCTC, liquid biopsy in precision oncology: a technology transfer experience in the Spanish health system.

    Science.gov (United States)

    Alonso-Alconada, L; Barbazan, J; Candamio, S; Falco, J L; Anton, C; Martin-Saborido, C; Fuster, G; Sampedro, M; Grande, C; Lado, R; Sampietro-Colom, L; Crego, E; Figueiras, S; Leon-Mateos, L; Lopez-Lopez, R; Abal, M

    2018-05-01

    Management of metastatic disease in oncology includes monitoring of therapy response principally by imaging techniques like CT scan. In addition to some limitations, the irruption of liquid biopsy and its application in personalized medicine has encouraged the development of more efficient technologies for prognosis and follow-up of patients in advanced disease. PrediCTC constitutes a panel of genes for the assessment of circulating tumor cells (CTC) in metastatic colorectal cancer patients, with demonstrated improved efficiency compared to CT scan for the evaluation of early therapy response in a multicenter prospective study. In this work, we designed and developed a technology transfer strategy to define the market opportunity for an eventual implementation of PrediCTC in the clinical practice. This included the definition of the regulatory framework, the analysis of the regulatory roadmap needed for CE mark, a benchmarking study, the design of a product development strategy, a revision of intellectual property, a cost-effectiveness study and an expert panel consultation. The definition and analysis of an appropriate technology transfer strategy and the correct balance among regulatory, financial and technical determinants are critical for the transformation of a promising technology into a viable technology, and for the decision of implementing liquid biopsy in the monitoring of therapy response in advanced disease.

  1. Association of plutonium with sediments from the Ob and Yenisey Rivers and Estuaries

    International Nuclear Information System (INIS)

    Skipperud, Lindis; Brown, Justin; Fifield, L. Keith; Oughton, Deborah H.; Salbu, Brit

    2009-01-01

    The present study applied sequential extraction techniques to investigate the binding and mobility of plutonium (Pu) in sediments from the rivers and estuaries of the Ob and Yenisey. As a study site, the Ob and Yenisey are particularly interesting as both rivers have weapons-grade Pu sources in their catchment areas, including the Russian Pu production and reprocessing plants at Mayak, Tomsk-7 and Krashnoyarsk, and the Semipalantinsk nuclear weapons testing site in Kazakhstan. Plutonium activity and 240 Pu/ 239 Pu ratios were determined using accelerator mass spectrometry (AMS). Sequential extractions showed that between 47 and 80% of the Pu in Yenisey River sediments and 35-53% of the Pu in soils around the Techa River are mobilized with weak oxidising agents, which can indicate that Pu is bound to organic material. In contrast, Pu in Ob and Yenisey Estuarine sediments was more strongly bound, with 60-100% being found in the HNO 3 -extractable fraction. This change in speciation could reflect either that Pu bound to organic material in the Techa and Yenisey River sediments becomes more fixed to the sediments with time, or that organic-bound Pu is mobilized and released to the water when the sediments encounter the more saline water of the Ob and Yenisey estuaries. In general, 240 Pu/ 239 Pu ratios were relatively consistent between different extraction fractions, although, in whole sediments, an increase in ratio was observed with distance from the source. This reflects the increased influence of weapon fallout from catchment runoff within the river systems, as compared to the weapons-grade sources close to the production and reprocessing plants. Knowledge of Pu speciation in the Ob and Yenisey Rivers, and the processes controlling its behaviour in estuarine systems, can improve predictions of its transfer and subsequent environmental impact to Arctic Seas

  2. Reverse time migration of multiples for OBS data

    KAUST Repository

    Zhang, Dongliang

    2014-01-01

    Reverse time migration of multiples (RTMM) is applied to OBS data with sparse receiver spacing. RTMM for OBS data unlike a marine streamer acquisition is implemented in the common receiver gathers (CRG) and provides a wider and denser illumination for each CRG than the conventional RTM of primaries. Hence, while the the conventional RTM image contains strong aliasing artifacts due to a sparser receiver interval, the RTMM image suffers from this artifacts less. This benefit of RTMM is demonstrated with numerical test on the Marmousi model for sparsely sampled OBS data.

  3. Searching for self-enrichment in Cygnus OB2

    Science.gov (United States)

    Berlanas, Sara R.; Herrero, Artemio; Comerón, Fernando; Pasquali, Anna; Simón-Díaz, Sergio

    2017-11-01

    Cygnus OB2 is a rich and relatively close (d~1.4 kpc) OB association in our Galaxy. It represents an ideal testbed for our theories about self-enrichment processes produced by pollution of the interstellar medium by successive generations of massive stars. Comerón & Pasquali (2012, A&A, 543, A101) found a correlation between the age of young stellar groups in Cygnus OB2 and their Galactic longitude. If is associated with a chemical composition gradient, it could support these self-enrichment processes.

  4. Reverse time migration of multiples for OBS data

    KAUST Repository

    Zhang, Dongliang

    2014-08-05

    Reverse time migration of multiples (RTMM) is applied to OBS data with sparse receiver spacing. RTMM for OBS data unlike a marine streamer acquisition is implemented in the common receiver gathers (CRG) and provides a wider and denser illumination for each CRG than the conventional RTM of primaries. Hence, while the the conventional RTM image contains strong aliasing artifacts due to a sparser receiver interval, the RTMM image suffers from this artifacts less. This benefit of RTMM is demonstrated with numerical test on the Marmousi model for sparsely sampled OBS data.

  5. No need for biopsies

    DEFF Research Database (Denmark)

    Gjødsbøl, Kristine; Skindersoe, Mette E; Christensen, Jens Jørgen

    2011-01-01

    The aim of the study was to compare three sampling techniques used in routine diagnostics to identify the microbiota in chronic venous leg ulcers. A total of 46 patients with persisting venous leg ulcers were included in the study. At inclusion, swab, biopsy and filter paper pad samples were...... collected. After 4 weeks, additional biopsy and filter paper pad samples were collected. Bacteria were isolated and identified at species level by standard methods. The most common bacterial species detected was Staphylococcus aureus found in 89% of the ulcers. No methicillin-resistant S. aureus isolates...... species present in chronic wounds, thus avoiding complications during and after biopsy sampling....

  6. MR-sequences for prostate cancer diagnostics: validation based on the PI-RADS scoring system and targeted MR-guided in-bore biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Schimmoeller, Lars; Quentin, Michael; Buchbender, Christian; Antoch, Gerald; Blondin, Dirk [University Dusseldorf, Medical Faculty, Department of Diagnostic and Interventional Radiology, Dusseldorf (Germany); Arsov, Christian; Hiester, Andreas; Rabenalt, Robert; Albers, Peter [University Dusseldorf, Medical Faculty, Department of Urology, Dusseldorf (Germany)

    2014-10-15

    This study evaluated the accuracy of MR sequences [T2-, diffusion-weighted, and dynamic contrast-enhanced (T2WI, DWI, and DCE) imaging] at 3T, based on the European Society of Urogenital Radiology (ESUR) scoring system [Prostate Imaging Reporting and Data System (PI-RADS)] using MR-guided in-bore prostate biopsies as reference standard. In 235 consecutive patients [aged 65.7 ± 7.9 years; median prostate-specific antigen (PSA) 8 ng/ml] with multiparametric prostate MRI (mp-MRI), 566 lesions were scored according to PI-RADS. Histology of all lesions was obtained by targeted MR-guided in-bore biopsy. In 200 lesions, biopsy revealed prostate cancer (PCa). The area under the curve (AUC) for cancer detection was 0.70 (T2WI), 0.80 (DWI), and 0.74 (DCE). A combination of T2WI + DWI, T2WI + DCE, and DWI + DCE achieved an AUC of 0.81, 0.78, and 0.79. A summed PI-RADS score of T2WI + DWI + DCE achieved an AUC of 0.81. For higher grade PCa (primary Gleason pattern ≥ 4), the AUC was 0.85 for T2WI + DWI, 0.84 for T2WI + DCE, 0.86 for DWI + DCE, and 0.87 for T2WI + DWI + DCE. The AUC for T2WI + DWI + DCE for transitional-zone PCa was 0.73, and for the peripheral zone 0.88. Regarding higher-grade PCa, AUC for transitional-zone PCa was 0.88, and for peripheral zone 0.96. The combination of T2WI + DWI + DCE achieved the highest test accuracy, especially in patients with higher-grade PCa. The use of ≤2 MR sequences led to lower AUC in higher-grade and peripheral-zone cancers. (orig.)

  7. MR-sequences for prostate cancer diagnostics: validation based on the PI-RADS scoring system and targeted MR-guided in-bore biopsy

    International Nuclear Information System (INIS)

    Schimmoeller, Lars; Quentin, Michael; Buchbender, Christian; Antoch, Gerald; Blondin, Dirk; Arsov, Christian; Hiester, Andreas; Rabenalt, Robert; Albers, Peter

    2014-01-01

    This study evaluated the accuracy of MR sequences [T2-, diffusion-weighted, and dynamic contrast-enhanced (T2WI, DWI, and DCE) imaging] at 3T, based on the European Society of Urogenital Radiology (ESUR) scoring system [Prostate Imaging Reporting and Data System (PI-RADS)] using MR-guided in-bore prostate biopsies as reference standard. In 235 consecutive patients [aged 65.7 ± 7.9 years; median prostate-specific antigen (PSA) 8 ng/ml] with multiparametric prostate MRI (mp-MRI), 566 lesions were scored according to PI-RADS. Histology of all lesions was obtained by targeted MR-guided in-bore biopsy. In 200 lesions, biopsy revealed prostate cancer (PCa). The area under the curve (AUC) for cancer detection was 0.70 (T2WI), 0.80 (DWI), and 0.74 (DCE). A combination of T2WI + DWI, T2WI + DCE, and DWI + DCE achieved an AUC of 0.81, 0.78, and 0.79. A summed PI-RADS score of T2WI + DWI + DCE achieved an AUC of 0.81. For higher grade PCa (primary Gleason pattern ≥ 4), the AUC was 0.85 for T2WI + DWI, 0.84 for T2WI + DCE, 0.86 for DWI + DCE, and 0.87 for T2WI + DWI + DCE. The AUC for T2WI + DWI + DCE for transitional-zone PCa was 0.73, and for the peripheral zone 0.88. Regarding higher-grade PCa, AUC for transitional-zone PCa was 0.88, and for peripheral zone 0.96. The combination of T2WI + DWI + DCE achieved the highest test accuracy, especially in patients with higher-grade PCa. The use of ≤2 MR sequences led to lower AUC in higher-grade and peripheral-zone cancers. (orig.)

  8. The positron emission mammography/tomography breast imaging and biopsy system (PEM/PET): design, construction and phantom-based measurements

    Science.gov (United States)

    Raylman, Raymond R.; Majewski, Stan; Smith, Mark F.; Proffitt, James; Hammond, William; Srinivasan, Amarnath; McKisson, John; Popov, Vladimir; Weisenberger, Andrew; Judy, Clifford O.; Kross, Brian; Ramasubramanian, Srikanth; Banta, Larry E.; Kinahan, Paul E.; Champley, Kyle

    2008-02-01

    Tomographic breast imaging techniques can potentially improve detection and diagnosis of cancer in women with radiodense and/or fibrocystic breasts. We have developed a high-resolution positron emission mammography/tomography imaging and biopsy device (called PEM/PET) to detect and guide the biopsy of suspicious breast lesions. PET images are acquired to detect suspicious focal uptake of the radiotracer and guide biopsy of the area. Limited-angle PEM images could then be used to verify the biopsy needle position prior to tissue sampling. The PEM/PET scanner consists of two sets of rotating planar detector heads. Each detector consists of a 4 × 3 array of Hamamatsu H8500 flat panel position sensitive photomultipliers (PSPMTs) coupled to a 96 × 72 array of 2 × 2 × 15 mm3 LYSO detector elements (pitch = 2.1 mm). Image reconstruction is performed with a three-dimensional, ordered set expectation maximization (OSEM) algorithm parallelized to run on a multi-processor computer system. The reconstructed field of view (FOV) is 15 × 15 × 15 cm3. Initial phantom-based testing of the device is focusing upon its PET imaging capabilities. Specifically, spatial resolution and detection sensitivity were assessed. The results from these measurements yielded a spatial resolution at the center of the FOV of 2.01 ± 0.09 mm (radial), 2.04 ± 0.08 mm (tangential) and 1.84 ± 0.07 mm (axial). At a radius of 7 cm from the center of the scanner, the results were 2.11 ± 0.08 mm (radial), 2.16 ± 0.07 mm (tangential) and 1.87 ± 0.08 mm (axial). Maximum system detection sensitivity of the scanner is 488.9 kcps µCi-1 ml-1 (6.88%). These promising findings indicate that PEM/PET may be an effective system for the detection and diagnosis of breast cancer.

  9. The positron emission mammography/tomography breast imaging and biopsy system (PEM/PET): design, construction and phantom-based measurements

    Energy Technology Data Exchange (ETDEWEB)

    Raylman, Raymond R [Center for Advanced Imaging, Department of Radiology, West Virginia University, Morgantown, WV (United States); Majewski, Stan [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Smith, Mark F [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Proffitt, James [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Hammond, William [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Srinivasan, Amarnath [Center for Advanced Imaging, Department of Radiology, West Virginia University, Morgantown, WV (United States); McKisson, John [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Popov, Vladimir [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Weisenberger, Andrew [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Judy, Clifford O [Department of Mechanical and Aerospace Engineering, West Virginia University, Morgantown, WV (United States); Kross, Brian [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Ramasubramanian, Srikanth [Center for Advanced Imaging, Department of Radiology, West Virginia University, Morgantown, WV (United States); Banta, Larry E [Department of Mechanical and Aerospace Engineering, West Virginia University, Morgantown, WV (United States); Kinahan, Paul E [Department of Radiology, University of Washington, Seattle, WA (United States); Champley, Kyle [Department of Radiology, University of Washington, Seattle, WA (United States)

    2008-02-07

    Tomographic breast imaging techniques can potentially improve detection and diagnosis of cancer in women with radiodense and/or fibrocystic breasts. We have developed a high-resolution positron emission mammography/tomography imaging and biopsy device (called PEM/PET) to detect and guide the biopsy of suspicious breast lesions. PET images are acquired to detect suspicious focal uptake of the radiotracer and guide biopsy of the area. Limited-angle PEM images could then be used to verify the biopsy needle position prior to tissue sampling. The PEM/PET scanner consists of two sets of rotating planar detector heads. Each detector consists of a 4 x 3 array of Hamamatsu H8500 flat panel position sensitive photomultipliers (PSPMTs) coupled to a 96 x 72 array of 2 x 2 x 15 mm{sup 3} LYSO detector elements (pitch = 2.1 mm). Image reconstruction is performed with a three-dimensional, ordered set expectation maximization (OSEM) algorithm parallelized to run on a multi-processor computer system. The reconstructed field of view (FOV) is 15 x 15 x 15 cm{sup 3}. Initial phantom-based testing of the device is focusing upon its PET imaging capabilities. Specifically, spatial resolution and detection sensitivity were assessed. The results from these measurements yielded a spatial resolution at the center of the FOV of 2.01 {+-} 0.09 mm (radial), 2.04 {+-} 0.08 mm (tangential) and 1.84 {+-} 0.07 mm (axial). At a radius of 7 cm from the center of the scanner, the results were 2.11 {+-} 0.08 mm (radial), 2.16 {+-} 0.07 mm (tangential) and 1.87 {+-} 0.08 mm (axial). Maximum system detection sensitivity of the scanner is 488.9 kcps {mu}Ci{sup -1} ml{sup -1} (6.88%). These promising findings indicate that PEM/PET may be an effective system for the detection and diagnosis of breast cancer.

  10. Evaluation of the ESUR PI-RADS scoring system for multiparametric MRI of the prostate with targeted MR/TRUS fusion-guided biopsy at 3.0 Tesla.

    Science.gov (United States)

    Roethke, M C; Kuru, T H; Schultze, S; Tichy, D; Kopp-Schneider, A; Fenchel, M; Schlemmer, H-P; Hadaschik, B A

    2014-02-01

    To evaluate the Prostate Imaging Reporting and Data System (PI-RADS) proposed by the European Society of Urogenital Radiology (ESUR) for detection of prostate cancer (PCa) by multiparametric magnetic resonance imaging (mpMRI) in a consecutive cohort of patients with magnetic resonance/transrectal ultrasound (MR/TRUS) fusion-guided biopsy. Suspicious lesions on mpMRI at 3.0 T were scored according to the PI-RADS system before MR/TRUS fusion-guided biopsy and correlated to histopathology results. Statistical correlation was obtained by a Mann-Whitney U test. Receiver operating characteristics (ROC) and optimal thresholds were calculated. In 64 patients, 128/445 positive biopsy cores were obtained out of 95 suspicious regions of interest (ROIs). PCa was present in 27/64 (42%) of the patients. ROC results for the aggregated PI-RADS scores exhibited higher areas under the curve compared to those of the Likert score. Sensitivity/Specificity for the following thresholds were calculated: 85 %/73 % and 67 %/92 % for PI-RADS scores of 9 and 10, respectively; 85 %/60 % and 56 %/97 % for Likert scores of 3 and 4, respectively [corrected. The standardised ESUR PI-RADS system is beneficial to indicate the likelihood of PCa of suspicious lesions on mpMRI. It is also valuable to identify locations to be targeted with biopsy. The aggregated PI-RADS score achieved better results compared to the single five-point Likert score. • The ESUR PI-RADS scoring system was evaluated using multiparametric 3.0-T MRI. • To investigate suspicious findings, transperineal MR/TRUS fusion-guided biopsy was used. • PI-RADS can guide biopsy locations and improve detection of clinically significant cancer. • Biopsy procedures can be optimised, reducing unnecessary negative biopsies for patients. • The PI-RADS scoring system may contribute to more effective prostate MRI.

  11. Implementation of double-C-arm synchronous real-time X-ray positioning system computer aided for aspiration biopsy of small lung lesion

    International Nuclear Information System (INIS)

    Zhu Hong; Wang Dong; Ye Yukun; Zhou Yuan; Lu Jianfeng; Yang Jingyu; Wang Lining

    2007-01-01

    Objective: To evaluate the feasibility of a new type of real-time three-dimensional X-ray positioning system for aspiration biopsy of small lung lesions. Methods: Using X-ray imaging technology and X-ray collimator technology and combining with double-C-arm X-ray machine, two different synchronous real-time images were obtained from the vertical to the horizontal plane. Then, with the computer image processing and computer vision processing technologies, dynamic tracking for 3D information of a pulmonary lesion and the needle in aspiration, and the relative position of the two, were established. Results: There was no interference while the two imaging perpendicularly X-ray beam met, two synchronous real-time image acquisition and tracking of a lung lesion and a needle could be completed in free respiration. The average positioning system error was about 0.5 mm, the largest positioning error was about 1.0 mm, real-time display rate was 5 screen/sec. Conclusions: the establishment of a new type of double-C-arm synchronous real-time X-ray positioning system is feasible. It is available for the fast and accurate aspiration biopsy of small lung lesions. (authors)

  12. Breast biopsy -- stereotactic

    Science.gov (United States)

    ... org/-/media/ACR/Files/Practice-Parameters/stereo-breast.pdf . Updated 2016. Accessed March 14, 2017. Parker C, Umphrey H, Bland K. The role of stereotactic breast biopsy in the management of breast disease. In: Cameron ...

  13. Breast biopsy -- ultrasound

    Science.gov (United States)

    ... org/-/media/ACR/Files/Practice-Parameters/us-guidedbreast.pdf . Updated 2016. Accessed March 14, 2017. Torrente J, Brem RF. Minimally invasive image-guided breast biopsy and ablation. In: Mauro MA, Murphy KPJ, Thomson ...

  14. Pleural needle biopsy

    Science.gov (United States)

    ... own. Sometimes, a chest tube is needed to drain the air and expand the lung. There is also a chance of excessive blood loss. Considerations If a closed pleural biopsy is not enough to make a diagnosis, ...

  15. Colposcopy - directed biopsy

    Science.gov (United States)

    ... squamous cells - colposcopy; Pap smear - colposcopy; HPV - colposcopy; Human papilloma virus - colposcopy; Cervix - colposcopy; Colposcopy ... also called cervical dysplasia) Cervical warts (infection with human papilloma virus , or HPV) If the biopsy does not ...

  16. Liver biopsy under hypnosis.

    Science.gov (United States)

    Adams, P C; Stenn, P G

    1992-09-01

    Two patients underwent outpatient percutaneous liver biopsy under hypnosis without complications. One patient had severe anxiety about the procedure because of a previous adverse experience with liver biopsy and the other had a history of severe allergy to local anesthesia. Both patients had undergone a session of hypnosis at least once prior to the biopsy. One received no local anesthetic and the other received 1% lidocaine as a local anesthetic. Both patients were completely cooperative during the procedure with the required respiratory maneuvers. Both patients stated that they were aware of the procedure under hypnosis but described no pain and would be most willing to have the procedure done under hypnosis in the future. Hypnosis can be a useful method of preparing carefully selected patients for percutaneous liver biopsy.

  17. Corpus vitreum, retina og chorioidea biopsi

    DEFF Research Database (Denmark)

    Scherfig, Erik Christian Høegh

    2002-01-01

    oftalmology, biopsy, choroid, corpus vitreum, retina, malignant melanoma, biopsy technic, retinoblastoma......oftalmology, biopsy, choroid, corpus vitreum, retina, malignant melanoma, biopsy technic, retinoblastoma...

  18. Biopsy in Musculoskeletal Tumors

    Directory of Open Access Journals (Sweden)

    Mohammad Gharehdaghi

    2014-09-01

    Full Text Available Diagnosis of bone tumors is based on careful evaluation of clinical, imaging and a pathologic findings. So the biopsy of bone and soft tissue sarcomas is the final step in evaluation and a fundamental step in the diagnosis of the lesion. It should not be performed as a shortcut to diagnosis (1. The biopsy should be performed in order to confirm the diagnosis and differentiate among few diagnoses after careful staged studies. Real and artificial changes in imaging studies will be superimposed after performing biopsy, which may alter the interpretation if done after biopsy is taken (1. The correct management of a sarcoma depends on the accurate diagnosis. Inadequate, inapprppriate, or inaccurate non-representative biopsy leads to poorer outcome in terms of survivorship and limb salvage. An incorrect, unplanned incision and biopsy may unnecessarily contaminate uninvolved compartments which may convert a salvageable limb to amputation. Anatomic approach along with the proper biopsy techniques may lead to success or catastrophe. It is clear that in patients with inappropriate biopsy, the chance of the need to change the treatment to more radical than would originally be expected is significantly higher. Also it is more probable to need to  convert curative to palliative treatment and to require adjuvant radiotherapy in patients with inappropriate biopsies. Patients with sarcoma are best served by early referral to a specialized center where staged investigations and biopsy can be performed with minimal morbidity (3. Open biopsy is still considered the gold standard; however, recent studies suggest comparable results with percutaneous core needle biopsy. Our study on 103 consecutive CNB and open biopsy showed comparable results as well. Surgeons need to answer to two questions prior to performing a biopsy: 1-          Where is the best part of the lesion to be biopsied? 2-          What is the safest route without contaminating

  19. A Novel Congestion Detection Scheme in TCP Over OBS Networks

    KAUST Repository

    Shihada, Basem; Ho, Pin-Han; Zhang, Qiong

    2009-01-01

    This paper introduces a novel congestion detection scheme for high-bandwidth TCP flows over optical burst switching (OBS) networks, called statistical additive increase multiplicative decrease (SAIMD). SAIMD maintains and analyzes a number

  20. Impaired transport of thyroid hormones into livers of obese (ob/ob) mice

    International Nuclear Information System (INIS)

    Hillgartner, F.B.; Romsos, D.R.

    1988-01-01

    Obese (ob/ob) mice exhibit impaired hepatic thyroid hormone action that is mediated, at least in part, by a reduced nuclear 3,5,3'-triiodothyronine (T 3 ) receptor occupancy. The possibility that lowered occupancy in obese mice may be caused by decreased transport of T 3 across the hepatic plasma membrane was examined by measuring the unidirectional influx of [ 125 I]T 3 into livers of 8- to 10-wk-old obese and lean mice using a tissue-sampling portal vein-injection technique. Influx of [ 125 I]thyroxine (T 4 ), a substrate for T 4 5'-deiodinase, was also measured. Unidirectional clearance of T 3 and T 4 was 64 and 80% lower, respectively, in obese mice than in lean mice. Hepatic T 3 and T 4 uptake was nonsaturable in both lean and obese mice, suggesting that transport occurs by lipid-mediated free diffusion. Clearance of another lipid-soluble hormone, hydrocortisone, was also lower in obese mice than in lean mice. Decreased membrane permeability to the above hormones in obese mice may result from reported changes in membrane lipid composition. In conclusion, decreased hepatic thyroid hormone uptake may contribute to impaired thyroid hormone action and T 3 production in livers of obese mice

  1. Nuclear triiodothyronine receptor binding characteristics and occupancy in obese (ob/ob) mice

    International Nuclear Information System (INIS)

    Hillgartner, F.B.; Romsos, D.R.

    1987-01-01

    Obese (ob/ob) mice exhibit reduced adaptive thermogenesis associated with an impairment of thyroid hormone action. The mechanism underlying the latter defect was investigated by comparing the binding characteristics and occupancy of solubilized nuclear 3,5,3'-triiodothyronine (T 3 ) receptors from livers of lean and obese mice. T 3 concentration was measured by radioimmunoassay. Scatchard analysis showed minimal differences in B/sub max/ and K/sub d/ between phenotypes at both 4 and 8-10 wk of age, indicating that reduced hepatic thyroid hormone expression in obese mice is not caused by alterations in nuclear receptor concentration or affinity. In contrast, nuclear T 3 receptor occupancy (endogenous T 3 associated with the specific receptor divided by B/sub max/) was 14 and 23% lower in 4- and 8- to 10-wk old obese mice, respectively. Together with reported changes in hepatic thyroid hormone-sensitive enzymes, these data are consistent with a diminished nuclear T 3 signal initiating thyroid hormone action in obese mice. Decreased nuclear T 3 receptor occupancy may be secondary to a low transport of plasma T 3 to the nuclear pool. In conclusion, impaired hepatic thyroid hormone action in obese mice is mediated in part at least by a reduction in nuclear T 3 receptor occupancy

  2. Electrical biopsy of irradiated intestinal tissue with a simple electrical impedance spectroscopy system for radiation enteropathy in rats—a pilot study

    International Nuclear Information System (INIS)

    Huang, Yu-Jie; Lu, Yi-Yu; Chen, Cheng-Yu; Cheng, Kuo-Sheng; Huang, Eng-Yen

    2011-01-01

    Electrical impedance is one of the most often used parameters for characterizing material properties, especially in biomedical applications. Electrical impedance spectroscopy (EIS), used for revealing both resistive and capacitive characteristics, is good for use in tissue characterization. In this study, a portable and simple EIS system based on a commercially available chip was used to assess rat intestinal tissues following irradiation. The EIS results were fitted to a resistor and capacitor electrical circuit model to solve the electrical properties of the tissue. The variation in the tissue's electrical characteristics was compared to the morphological and histological findings. From the experimental results, it was clear that the electrical properties, based on receiver operation curve analysis, demonstrated good detection performance relative to the histological changes. The electrical parameters of the tissues could be used to distinguish the tissue's status for investigation, which introduced a concept of 'electrical biopsy', and this 'electrical biopsy' approach may be used to complement histological examinations

  3. Hardness properties and microscopic investigation of crack- crystal interaction in SiO(2)-MgO-Al(2)O(3)-K(2)O-B(2)O(3)-F glass ceramic system.

    Science.gov (United States)

    Roy, Shibayan; Basu, Bikramjit

    2010-01-01

    In view of the potential engineering applications requiring machinability and wear resistance, the present work focuses to evaluate hardness property and to understand the damage behavior of some selected glass-ceramics having different crystal morphologies with SiO(2)-MgO-Al(2)O(3)-K(2)O-B(2)O(3)-F composition, using static micro-indentation tests as well as dynamic scratch tests, respectively. Vickers hardness of up to 5.5 GPa has been measured in glass-ceramics containing plate like mica crystals. Scratch tests at a high load of 50 Nin artificial saliva were carried out in order to simulate the crack-microstructure interaction during real-time abrasion wear and machining operation. The experimental observations indicate that the novel "spherulitic-dendritic shaped "crystals, similar to the plate like crystals, have the potential to hinder the scratching induced crack propagation. In particular, such potential of the 'spherulitic-dendritic' crystals become more effective due to the larger interfacial area with the glass matrix as well as the dendritic structure of each mica plate, which helps in crack deflection and crack blunting, to a larger extent.While modest damage tolerant behavior is observed in case of 'spherulitic-dendritic' crystal containing material, severe brittle fracture of plate like crystals were noted, when both were scratched at 50 N load.

  4. Kefir improves fatty liver syndrome by inhibiting the lipogenesis pathway in leptin-deficient ob/ob knockout mice.

    Science.gov (United States)

    Chen, H-L; Tung, Y-T; Tsai, C-L; Lai, C-W; Lai, Z-L; Tsai, H-C; Lin, Y-L; Wang, C-H; Chen, C-M

    2014-09-01

    Fatty liver disease is commonly associated with obesity, insulin resistance and diabetes. Severe fatty liver is sometimes accompanied by steatohepatitis and may lead to the development of hepatocellular carcinoma. At present, there is no effective treatment for non-alcoholic fatty liver disease (NAFLD); thus, recent investigations have focused on developing effective therapeutics to treat this condition. This study aimed to evaluate the effects of kefir on the hepatic lipid metabolism of ob/ob mice, which are commonly used to model fatty liver disease. In this study, we used leptin receptor-deficient ob/ob mice as an animal disease model of NAFLD. Six-week-old ob/ob mice were orally administered the dairy product kefir (140 mg kg(-1) of body weight (BW) per day) for 4 weeks. The data demonstrated that kefir improved fatty liver syndrome on BW, energy expenditure and basal metabolic rate by inhibiting serum glutamate oxaloacetate transaminase (GOT) and glutamate pyruvate transaminase (GPT) activities (Pkefir administration also significantly reduced the macrovesicular fat quantity in liver tissue. In addition, kefir markedly decreased the expression of the genes sterol regulatory element-binding protein 1 (SREBP1), fatty acid synthase (FAS) and acetyl-CoA carboxylase (ACC) (Pkefir improves NAFLD on BW, energy expenditure and basal metabolic rate by inhibiting the lipogenesis pathway and that kefir may have the potential for clinical application to the prevention or treatment of NAFLD.

  5. Interventional bleeding, hematoma and scar-formation after vacuum-biopsy under stereotactic guidance: Mammotome®-system 11g/8g vs. ATEC®-system 12g/9g

    International Nuclear Information System (INIS)

    Schaefer, F.K.W.; Order, B.M.; Eckmann-Scholz, C.; Strauss, A.; Hilpert, F.; Kroj, K.; Biernath-Wüpping, J.; Heller, M.; Jonat, W.; Schaefer, P.J.

    2012-01-01

    Purpose: To evaluate prospectively the correlation of scar-formations after vacuum-assisted biopsy with different systems and needle-sizes and interventional bleeding/post-interventional hematoma. Methods and materials: Between 01/2008 and 12/2009, 479 patients underwent vacuum-assisted biopsy under stereotactic-guidance, using the Mammotome ® -system with 11/8-gauge and ATEC ® -system with 12/9-gauge, whereas in 178 cases with representative benign histology no surgical-biopsy after vacuum-assisted biopsy was performed and at least a 2-plane-follow-up-mammogram after 6 month post-vacuum-assisted biopsy was available. Bleeding during intervention, hematoma post-intervention and scar-tissue was scored as minimal and moderate/severe. Statistical analysis included Chi-Square-trend-test, p-value ® -system vs. 11-gauge-Mammotome ® -system (41.9% vs. 8.4%, p ® -systems 9-gauge vs. 12-gauge (26.9% vs. 29.7%, p = 0.799/42.3% vs. 43.2%, p = 0.596). 11-gauge-Mammotome ® -system vs. ATEC ® -12-gauge-system revealed significantly less bleedings/hematomas (8.4% vs. 29.7%, p = 0.015/16.7% vs. 43.2%, p = 0.001), no significant differences for the large-systems (p = 0.135/p = 0.352). Follow-up of Mammotome ® -11/8-gauge-system system has shown 13.1/16.1% minimal scar-formation and 1.2/3.2% moderate/severe scars, whereas ATEC ® -12/9-gauge-system has shown 10.8/3.8% minimal scar-formation and 0/11.5% moderate/severe scars, no significant differences. No significant difference was found when comparing Mammotome ® -11/8-g-systems vs. ATEC ® -12/9-g-systems (p = 0.609/p = 0.823). There was also no correlation between risk of scar-formation after occurrence of bleeding or hematoma with any examined VAB-system or any needle size in this study (p = 0.800). Conclusion: Using larger needle-sizes significantly (Mammotome ®) /not significant for ATEC ® ) more interventional bleedings and post-interventional hematomas were detected, only a tendency concerning scar-formation.

  6. Hormone-sensitive lipase deficiency suppresses insulin secretion from pancreatic islets of Lepob/ob mice

    International Nuclear Information System (INIS)

    Sekiya, Motohiro; Yahagi, Naoya; Tamura, Yoshiaki; Okazaki, Hiroaki; Igarashi, Masaki; Ohta, Keisuke; Takanashi, Mikio; Kumagai, Masayoshi; Takase, Satoru; Nishi, Makiko; Takeuchi, Yoshinori; Izumida, Yoshihiko; Kubota, Midori; Ohashi, Ken; Iizuka, Yoko; Yagyu, Hiroaki; Gotoda, Takanari; Nagai, Ryozo; Shimano, Hitoshi; Yamada, Nobuhiro

    2009-01-01

    It has long been a matter of debate whether the hormone-sensitive lipase (HSL)-mediated lipolysis in pancreatic β-cells can affect insulin secretion through the alteration of lipotoxicity. We generated mice lacking both leptin and HSL (Lep ob/ob /HSL -/- ) and explored the role of HSL in pancreatic β-cells in the setting of obesity. Lep ob/ob /HSL -/- developed elevated blood glucose levels and reduced plasma insulin levels compared with Lep ob/ob /HSL +/+ in a fed state, while the deficiency of HSL did not affect glucose homeostasis in Lep +/+ background. The deficiency of HSL exacerbated the accumulation of triglycerides in Lep ob/ob islets, leading to reduced glucose-stimulated insulin secretion. The deficiency of HSL also diminished the islet mass in Lep ob/ob mice due to decreased cell proliferation. In conclusion, HSL affects insulin secretary capacity especially in the setting of obesity.

  7. Hypothalamic Leptin Gene Therapy Reduces Bone Marrow Adiposity in ob/ob Mice Fed Regular and High Fat Diets

    Directory of Open Access Journals (Sweden)

    Laurence B Lindenmaier

    2016-08-01

    Full Text Available Low bone mass is often associated with increased bone marrow adiposity. Since osteoblasts and adipocytes are derived from the same mesenchymal stem cell progenitor, adipocyte formation may increase at the expense of osteoblast formation. Leptin is an adipocyte-derived hormone known to regulate energy and bone metabolism. Genetic (e.g., leptin deficiency and high fat diet-induced (e.g., leptin resistance obesity are associated with increased marrow adipose tissue (MAT and reduced bone formation. Short-duration studies suggest that leptin treatment reduces MAT and increases bone formation in leptin-deficient ob/ob mice fed a regular diet. Here, we determined the long-duration impact of increased hypothalamic leptin on marrow adipocytes and osteoblasts in ob/ob mice using recombinant adeno-associated virus (rAAV gene therapy. In a first study, eight- to ten-week-old male ob/ob mice were randomized into 4 groups: (1 untreated, (2 rAAV-Lep, (3 rAAV-green fluorescent protein (rAAV-GFP, or (4 pair-fed to rAAV-Lep. For vector administration, mice were placed in a Kopf stereotaxic apparatus, and injected intracerebroventricularly with either rAAV-Lep or rAAV-GFP (9 × 107 particles in 1.5 µl. The mice were maintained for 30 weeks following vector administration. In a second study, the impact of increased hypothalamic leptin levels on MAT was determined in mice fed high fat diets. Eight- to ten-week-old male ob/ob mice were randomized into 2 groups and treated with either rAAV-Lep or rAAV-GFP. At 7 weeks post-vector administration, half the mice in each group were switched to a high fat diet for 8 weeks. Wild type (WT controls included age-matched mice fed regular or high fat diet. Hypothalamic leptin gene therapy increased osteoblast perimeter and osteoclast perimeter with minor change in cancellous bone architecture. The gene therapy decreased MAT levels in ob/ob mice fed regular or high fat diet to values similar to WT mice fed regular diet. These

  8. Lung needle biopsy

    Science.gov (United States)

    ... if you have certain lung diseases such as emphysema. Usually, a collapsed lung after a biopsy does not need treatment. But ... any type Bullae (enlarged alveoli that occur with emphysema) Cor pulmonale (condition ... of the lung High blood pressure in the lung arteries Severe ...

  9. Closed Pericardial Biopsy

    African Journals Online (AJOL)

    1974-09-28

    Sep 28, 1974 ... The instrument used is a hook biopsy needle (Fig. I). manufactured by Becton, Dickinson and Co., Rutherford,. New Jersey, USA. The instrument' and technique' will be reviewed. The instrument consists of an ll-gauge needle with a sharp cutting edge into which fits, interchangeably, a 13-gauge needle or a ...

  10. CONE BIOPSY IN PREGNANCY*

    African Journals Online (AJOL)

    1 Mei 1971. S.-A. TYDSKRIF VIR OBSTETRIE EN GINEKOLOGIE. CONE BIOPSY ... of the abnormal cervix in pregnancy is also no longer in question following the .... the concept of cancer prophylaxis to the majority of women, many of whom ...

  11. Transbronchial biopsies safely diagnose amyloid lung disease

    Science.gov (United States)

    Govender, Praveen; Keyes, Colleen M.; Hankinson, Elizabeth A.; O’Hara, Carl J.; Sanchorawala, Vaishali; Berk, John L.

    2018-01-01

    Background Autopsy identifies lung involvement in 58–92% of patients with the most prevalent forms of systemic amyloidoses. In the absence of lung biopsies, amyloid lung disease often goes unrecognized. Report of a death following transbronchial biopsies in a patient with systemic amyloidosis cautioned against the procedure in this patient cohort. We reviewed our experience with transbronchial biopsies in patients with amyloidosis to determine the safety and utility of bronchoscopic lung biopsies. Methods We identified patients referred to the Amyloidosis Center at Boston Medical Center with lung amyloidosis diagnosed by transbronchial lung biopsies (TBBX). Amyloid typing was determined by immunohistochemistry or mass spectrometry. Standard end organ assessments, including pulmonary function test (PFT) and chest tomography (CT) imaging, and extra-thoracic biopsies established the extent of disease. Results Twenty-five (21.7%) of 115 patients with lung amyloidosis were diagnosed by TBBX. PFT classified 33.3% with restrictive physiology, 28.6% with obstructive disease, and 9.5% mixed physiology; 9.5% exhibited isolated diffusion defects while 19% had normal pulmonary testing. Two view chest or CT imaging identified focal opacities in 52% of cases and diffuse interstitial disease in 48%. Amyloid type and disease extent included 68% systemic AL disease, 16% localized (lung limited) AL disease, 12% ATTR disease, and 4% AA amyloidosis. Fluoroscopy was not used during biopsy. No procedure complications were reported. Conclusions Our case series of 25 patients supports the use of bronchoscopic transbronchial biopsies for diagnosis of parenchymal lung amyloidosis. Normal PFTs do not rule out the histologic presence of amyloid lung disease. PMID:28393574

  12. Toward Complete Statistics of Massive Binary Stars: Penultimate Results from the Cygnus OB2 Radial Velocity Survey

    OpenAIRE

    Kobulnicky, Henry A.; Kiminki, Daniel C.; Lundquist, Michael J.; Burke, Jamison; Chapman, James; Keller, Erica; Lester, Kathryn; Rolen, Emily K.; Topel, Eric; Bhattacharjee, Anirban; Smullen, Rachel A.; Alvarez, Carlos A. Vargas; Runnoe, Jessie C.; Dale, Daniel A.; Brotherton, Michael M.

    2014-01-01

    We analyze orbital solutions for 48 massive multiple-star systems in the Cygnus OB2 Association, 23 of which are newly presented here, to find that the observed distribution of orbital periods is approximately uniform in log P for P 45 d, even after correction for completeness, indicating either a lower binary fraction or a shift toward low-mass companions. A high degree of similarity (91% likelihood) between the Cyg OB2 period distribution and that of other surveys suggests that the binary p...

  13. ObsPy – What can it do for data centers and observatories?

    Directory of Open Access Journals (Sweden)

    Joachim Wassermann

    2011-04-01

    Full Text Available Data acquisition by seismic centers relies on real-time systems, like SeisComP3, Antelope and Earthworm. However, these are complex systems that are designed for fast and precisely defined standard real-time analyses. Therefore, it is not a simple task to access or modify internal routines, and to integrate them into custom-processing workflows or to perform in-depth data analyses. Often a library is necessary that provides convenient access to data and allows easy control over all of the operations that are to be performed on the data. ObsPy is such a library, which is designed to access and process seismological waveform data and metadata. We use short and simple examples here to demonstrate how effective it is to use Python for seismological data analysis. Then, we illustrate the general capabilities of ObsPy, and highlight some of its specific aspects that are relevant for seismological data centers and observatories, through presentation of real-world examples. Finally, we demonstrate how the ObsPy library can be used to develop custom graphical user interface applications.

  14. Computed tomography guidance for skeletal biopsy

    International Nuclear Information System (INIS)

    Frager, D.H.; Goldman, M.J.; Elkin, C.M.; Cynamon, J.; Leeds, N.E.; Seimon, L.P.; Habermann, E.T.; Schreiber, K.; Freeman, L.M.

    1987-01-01

    Computed tomographic (CT) guided biopsy and abscess drainage of multiple organ systems have been well described. Reports of spinal and skeletal applications have been less common. This study describes the use of CT guidance in the biopsy of various skeletal lesions in 46 patients. Forty-one patients had skinny needle aspirations (18 or 22 gauge) and 23 patients had trephine core biopsies. Sites of the lesions included: thoracic spine - 15 patients, lumbosacral spine - 17 patients, bony pelvis - 6 patients, rib - 2 patients, and long bones - 6 patients. Fast scanners capable of rapid image reconstruction have overcome many constraints. With CT guidance, the physician who performs the procedure receives virtually no ionizing radiation. The exact location of the needle tip is accurately visualized in relation to the lesion being biopsied and to the vital organs. (orig.)

  15. Magnetic resonance imaging-guided biopsies may improve diagnosis in biopsy-naive men with suspicion of prostate cancer

    DEFF Research Database (Denmark)

    Winther, Mads Dochedahl; Balslev, Ingegerd; Boesen, Lars

    2017-01-01

    INTRODUCTION: The purpose of this pilot study was to investigate whether a short prostate biparametric magnetic resonance imaging (bp-MRI) protocol provides a valuable diagnostic addition for biopsy guidance in biopsy-naive men with a suspicion of prostate cancer (PCa). METHODS: A total of 62...... biopsy-naive patients referred to a systematic transrectal ultrasound biopsy (TRUS-bx) due to suspicion of PCa were prospectively enrolled. Bp-MRI was performed before biopsy. All lesions were scored according to the modified Prostate Imaging Reporting and Data System (PI-RADS) version 2. All patients...

  16. An unidentified TeV source in the vicinity of Cygnus OB2

    Science.gov (United States)

    Aharonian, F.; Akhperjanian, A.; Beilicke, M.; Bernlöhr, K.; Börst, H.; Bojahr, H.; Bolz, O.; Coarasa, T.; Contreras, J.; Cortina, J.; Denninghoff, S.; Fonseca, V.; Girma, M.; Götting, N.; Heinzelmann, G.; Hermann, G.; Heusler, A.; Hofmann, W.; Horns, D.; Jung, I.; Kankanyan, R.; Kestel, M.; Kettler, J.; Kohnle, A.; Konopelko, A.; Kornmeyer, H.; Kranich, D.; Krawczynski, H.; Lampeitl, H.; Lopez, M.; Lorenz, E.; Lucarelli, F.; Magnussen, N.; Mang, O.; Meyer, H.; Milite, M.; Mirzoyan, R.; Moralejo, A.; Ona, E.; Panter, M.; Plyasheshnikov, A.; Prahl, J.; Pühlhofer, G.; Rauterberg, G.; Reyes, R.; Rhode, W.; Ripken, J.; Röhring, A.; Rowell, G. P.; Sahakian, V.; Samorski, M.; Schilling, M.; Schröder, F.; Siems, M.; Sobzynska, D.; Stamm, W.; Tluczykont, M.; Völk, H. J.; Wiedner, C. A.; Wittek, W.; Uchiyama, Y.; Takahashi, T.; HEGRA Collaboration

    2002-10-01

    Deep observation ( ~ 113 hrs) of the Cygnus region at TeV energies using the HEGRA stereoscopic system of air Čerenkov telescopes has serendipitously revealed a signal positionally inside the core of the OB association Cygnus OB2, at the edge of the 95% error circle of the EGRET source 3EG J2033+4118, and ~ 0.5o north of Cyg X-3. The source centre of gravity is RA alphaJ2000: 20h 32m 07s+/- 9.2sstat +/-2.2ssys, Dec deltaJ2000: +41o 30' 30''+/- 2.0'stat +/- 0.4'sys. The source is steady, has a post-trial significance of +4.6sigma , indication for extension with radius 5.6' at the ~ 3sigma level, and has a differential power-law flux with hard photon index of -1.9 +/-0.3stat +/-0.3sys. The integral flux above 1 TeV amounts ~ 3% that of the Crab. No counterpart for the TeV source at other wavelengths is presently identified, and its extension would disfavour an exclusive pulsar or AGN origin. If associated with Cygnus OB2, this dense concentration of young, massive stars provides an environment conducive to multi-TeV particle acceleration and likely subsequent interaction with a nearby gas cloud. Alternatively, one could envisage gamma -ray production via a jet-driven termination shock.

  17. KIT D816V mutation-positive cell fractions in lesional skin biopsies from adults with systemic mastocytosis

    DEFF Research Database (Denmark)

    Kielsgaard Kristensen, Thomas; Broesby-Olsen, Sigurd; Vestergaard, Hanne

    2013-01-01

    Most adults with systemic mastocytosis (SM) carry the somatic KIT D816V mutation, but the occurrence of the mutation in lesional skin remains to be characterized.......Most adults with systemic mastocytosis (SM) carry the somatic KIT D816V mutation, but the occurrence of the mutation in lesional skin remains to be characterized....

  18. Mining the Obscured OB Star Population in Carina

    Science.gov (United States)

    Smith, Michael

    2016-04-01

    Massive OB stars are very influential objects in the ecology of galaxies like our own. Current catalogues of Galactic OB stars are heavily biased towards bright (g selected OB stars across the entire Southern Galactic plane, both within clusters and in the field, down to ∼20th magnitude in g. For the first time, a complete accounting of the OB star runaway phenomenon becomes possible. Along with making the primary selection using VPHAS+ colours, I have performed Markov-Chain Monte Carlo fitting of the spectral energy distributions of the selected stars by combining VPHAS+ u, g, r, i with published J, H, K photometry. This gives rough constraints on effective temperature and distance, whilst delivering much more precise reddening parameters A0 and RV - allowing us to build a much richer picture of how extinction and extinction laws vary across the Galactic Plane. My thesis begins with a description of the method of photometric selection of OB star candidates and its validation across a 2 square degree field including the well-known young massive star cluster Westerlund 2 (Mohr-Smith et al., 2015). Following on from this I present spectroscopy with AAOmega of 283 candidates identified by our method, which confirms that ∼94% of the sample are the expected O and early B stars. I then develop this method further and apply it to a Galactic Plane strip of 42 square-degrees that runs from the Carina Arm tangent region to the much studied massive cluster in NGC 3603. A new aspect I attend to in this expansion of method is tightening up the uniform photometric calibration of the data, paying particular attention to the always-challenging u band. This leads to a new and reliable catalogue of 5915 OB stars. As well as increasing the numbers of identified massive stars in this large region of the sky by nearly an order of magnitude, a more complete picture of massive star formation in the Carina Arm has emerged. I have found a broad over-density of O stars around the highly

  19. Image-Guided percutaneous biopsies with a biopsy gun

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kyung Hwan; Lim, Hyo Keun; Kim, Eun Ah; Yun, Ku Sub; Bae, Sang Hoo; Shin, Hyung Sik [Hallym University College of Medicine, Seoul (Korea, Republic of)

    1994-07-15

    We report the results of image-guided percutaneous biopsies with a biopsy gun and evaluate the clinical usefulness. One hundred and five biopsies under ultrasonographic or fluoroscopic guidance were performed. Various anatomic sites were targeted(liver; 50, chest; 22, kidney; 12, pancreas; 8, intraperitoeum; 7, retroperitoneum; ). Obtained tissue was diagnostic in 98 of the 105 biopsies(93%). In each instance, representative core tissue specimens were obtained. Evaluation of the core tissue by pathologist revealed consistent, uniform specimens that contained significant crush artifact in no case. Five biopsies yielded inadequate tissue which were too small for histopathologic interpretation or were composed of necrotic debris. Two biopsies yielded adequate tissues, but tissues were not of the target. The diagnoses were malignancy in 77 biopsies and benign disease in 21 biopsies. No complications other than mild, localized discomfort were encountered except a transient hemoptysis and pneumothorax which was observed in two patients. Cutting biopsy with a biopsy gun provided sufficient amount of target tissue for an accurate diagnosis of malignant and benign disease. It was a safe and useful procedure for percutaneous biopsy.

  20. Radiologically Guided Bone Biopsy: Results of 502 Biopsies

    International Nuclear Information System (INIS)

    Ng, Chaan S.; Salisbury, Jonathan R.; Darby, Alan J.; Gishen, Philip

    1998-01-01

    Purpose: To analyze the results of 502 biopsies over a 19-year period for the purpose of highlighting the results that can be expected from such a large study, with emphasis on needle choice and anesthetic methods. Methods: The histological, cytological, and microbiological results of 477 patients who had 502 bone biopsies carried out between July 1977 and March 1996 were studied. Less than 5% of patients required second biopsies. There were almost equal numbers of males and females in the group. The lesions were visible radiologically and most of the biopsies were carried out by a single operator. The lesions were classified on their histopathological, cytopathological, and microbiological findings. Results: Tumors accounted for 40% of the biopsies, and infection for 16%. Biopsies which did not yield a 'positive' diagnosis accounted for 31%; these included specimens reported as normal, or as showing reactive changes, repair, remodelling, non-specific features, inflammation (but not clearly infective), or no evidence of malignancy or inflammation. Less than 4% of biopsies were incorrect, and some of these were re-biopsied. Conclusion: Bone biopsy is a valuable technique for positive diagnosis of malignancy or infection, as it enables a definitive plan for treatment and management of patients to be established. Exclusion of serious pathology is almost equally important. In principle, any osseous site can be biopsied using fluoroscopic or computed tomographic guidance. Care in the biopsy technique and selection of the bone needle is required

  1. US-guided percutaneous biopsies with a biopsy gun

    International Nuclear Information System (INIS)

    Ahn, In Oak; Kim, Hyung Jin; Kim, Jae Hyung; Lee, Goo; Jung, Sung Hoon

    1993-01-01

    Core tissue for histologic study is believed by many pathologist to be more diagnostic than material from needle aspiration. Recently introduced automatched biopsy gun simplifies core biopsies with increased quantity and quality of samples. Authors performed 38 percutaneous biopsies from 38 patients with 18G automated biopsy guns under US guide. Diagnostic target tissues were obtained in 33 biopsies(87%), inadequate tissues in 4(11%), and adequate but not of target tissue in 1(3%). There was no major complication requiring treatment, but pain needing analgesics and pain with nausea/vomiting were experienced in 2 and 1 biopsies respectively. Average number of needle passes was 1.5. We concluded that US guided gun biopsy was a easy and safe way to obtain tissue samples of good quantity and quality, especially useful in hospitals without constant availability of specialist in cytopathology

  2. Accuracy of biopsy needle navigation using the Medarpa system - computed tomography reality superimposed on the site of intervention

    International Nuclear Information System (INIS)

    Khan, M. Fawad; Maataoui, Adel; Gurung, Jessen; Schiemann, Mirko; Vogl, Thomas J.; Dogan, Selami; Ackermann, Hanns; Wesarg, Stefan; Sakas, Georgios

    2005-01-01

    The aim of this work was to determine the accuracy of a new navigational system, Medarpa, with a transparent display superimposing computed tomography (CT) reality on the site of intervention. Medarpa uses an optical and an electromagnetic tracking system which allows tracking of instruments, the radiologist and the transparent display. The display superimposes a CT view of a phantom chest on a phantom chest model, in real time. In group A, needle positioning was performed using the Medarpa system. Three targets (diameter 1.5 mm) located inside the phantom were punctured. In group B, the same targets were used to perform standard CT-guided puncturing using the single-slice technique. The same needles were used in both groups (15 G, 15 cm). A total of 42 punctures were performed in each group. Post puncture, CT scans were made to verify needle tip positions. The mean deviation from the needle tip to the targets was 6.65±1.61 mm for group A (range 3.54-9.51 mm) and 7.05±1.33 mm for group B (range 4.10-9.45 mm). No significant difference was found between group A and group B for any target (p>0.05). No significant difference was found between the targets of the same group (p>0.05). The accuracy in needle puncturing using the augmented reality system, Medarpa, matches the accuracy achieved by CT-guided puncturing technique. (orig.)

  3. Nail biopsy: A user's manual

    Directory of Open Access Journals (Sweden)

    Chander Grover

    2018-01-01

    Full Text Available Nail biopsy is a procedure not routinely resorted to; but when indicated, it is often the only clue left for diagnosis. At such times, it pays to be conversant with it. It is an investigation that not only provides etiologic, diagnostic, and prognostic information but also aids in understanding the pathogenesis of nail diseases. It can be of therapeutic value, especially with respect to nail tumors. This article compiles the procedural techniques for nail biopsy of various types and attempts to summarize the evidence available in the literature. The objective of nail biopsy is to clinch a precise diagnosis of nail pathology with a simple and safe surgical procedure, avoiding pain or permanent nail damage. Patient selection is of utmost importance, wherein, the patient does not have typical skin lesions, yields inadequate information on routine nail investigations, and has no peripheral vascular compromise. The patient needs to be explained about the risks associated, the expected functional handicap, the time required for regrowth, a possibility of permanent nail dystrophy, and a possibility of not achieving a diagnosis even after the biopsy. Techniques and types of various nail biopsies are being discussed in this article. The specimen could be collected as an excision biopsy, punch biopsy, shave biopsy, or longitudinal biopsy. The trick lies in choosing the appropriate area for biopsy. Various biopsy types discussed in this article include nail plate biopsy (easiest and least scarring; nail bed biopsy (elliptical excision or punch; nail matrix biopsy (elliptical excision, punch excision (≤3 mm or tangential/shave excision; and nail fold biopsy. Complications reported along with means to minimize them are also discussed.

  4. The biopsy of the boar testes using ultrasonographic examination

    Directory of Open Access Journals (Sweden)

    Laima Liepa

    2014-03-01

    Full Text Available The biopsy of live animal testes is an important clinical manipulation to control spermatogenesis and reproductive system pathologies. The aim was to develop a method of boar testes biopsy using a biopsy gun with ultrasound guidance and to investigate the influence of this procedure on the boar testes parenchyma and quality of ejaculate. The biopsy was carried out in six 8-month-old boars. Fourteen days prior to and 21 days after biopsy, the quality of ejaculate was examined (weight of ejaculate; concentration and motility of spermatozoa with a seven-day intervals. Ultrasound images of the testes parenchyma were recorded three times: directly before and 15 minutes after the biopsy, then 21 days after the procedure. The testes biopsies of generally anesthetized boars were performed with the biopsy gun for needle biopsy with a 12cm long, disposable 16-gauge needle 1.8mm in diameter (Vitesse through 1cm skin incision in the depth of 1.2-1.6cm of parenchyma. Fifteen minutes after the biopsy, macroscopic injures of the parenchyma of all the boar testes were not detected in the ultrasound image. Twenty one days after biopsy, the hyperechogenic line 0.1-0.2cm in diameter was seen in the testes parenchyma of six boars in the depth of 1.2-1.6cm. The biopsy of boar testes did not influence the quality of boars ejaculate. The ultrasonographic examination of boar testicles before the biopsy reduced possibilities to traumatize large blood vessels of the testes. A perfect boar testicular biopsy was easy to perform using ultrasonographic examination in the pigsty conditions.

  5. Usefulness of automated biopsy guns in image-guided biopsy

    International Nuclear Information System (INIS)

    Lee, Jung Hyung; Rhee, Chang Soo; Lee, Sung Moon; Kim, Hong; Woo, Sung Ku; Suh, Soo Jhi

    1994-01-01

    To evaluate the usefulness of automated biopsy guns in image-guided biopsy of lung, liver, pancreas and other organs. Using automated biopsy devices, 160 biopsies of variable anatomic sites were performed: Biopsies were performed under ultrasonographic(US) guidance in 95 and computed tomographic (CT) guidance in 65. We retrospectively analyzed histologic results and complications. Specimens were adequate for histopathologic diagnosis in 143 of the 160 patients(89.4%)-Diagnostic tissue was obtained in 130 (81.3%), suggestive tissue obtained in 13(8.1%), and non-diagnostic tissue was obtained in 14(8.7%). Inadequate tissue was obtained in only 3(1.9%). There was no statistically significant difference between US-guided and CT-guided percutaneous biopsy. There was no occurrence of significant complication. We have experienced mild complications in only 5 patients-2 hematuria and 2 hematochezia in transrectal prostatic biopsy, and 1 minimal pneumothorax in CT-guided percutaneous lung biopsy. All of them were resolved spontaneously. The image-guided biopsy using the automated biopsy gun was a simple, safe and accurate method of obtaining adequate specimen for the histopathologic diagnosis

  6. Usefulness of automated biopsy guns in image-guided biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jung Hyung; Rhee, Chang Soo; Lee, Sung Moon; Kim, Hong; Woo, Sung Ku; Suh, Soo Jhi [School of Medicine, Keimyung University, Daegu (Korea, Republic of)

    1994-12-15

    To evaluate the usefulness of automated biopsy guns in image-guided biopsy of lung, liver, pancreas and other organs. Using automated biopsy devices, 160 biopsies of variable anatomic sites were performed: Biopsies were performed under ultrasonographic(US) guidance in 95 and computed tomographic (CT) guidance in 65. We retrospectively analyzed histologic results and complications. Specimens were adequate for histopathologic diagnosis in 143 of the 160 patients(89.4%)-Diagnostic tissue was obtained in 130 (81.3%), suggestive tissue obtained in 13(8.1%), and non-diagnostic tissue was obtained in 14(8.7%). Inadequate tissue was obtained in only 3(1.9%). There was no statistically significant difference between US-guided and CT-guided percutaneous biopsy. There was no occurrence of significant complication. We have experienced mild complications in only 5 patients-2 hematuria and 2 hematochezia in transrectal prostatic biopsy, and 1 minimal pneumothorax in CT-guided percutaneous lung biopsy. All of them were resolved spontaneously. The image-guided biopsy using the automated biopsy gun was a simple, safe and accurate method of obtaining adequate specimen for the histopathologic diagnosis.

  7. Endobronkial ultralydsskanning af mediastinum med biopsi

    DEFF Research Database (Denmark)

    Siemsen, Mette; Steffensen, Ida E; Iversen, Martin

    2010-01-01

    Endobronchial ultrasound (EBUS) is a minimally invasive diagnostic modality, by which it is possible to visualize and do biopsy of structures adjacent to the trachea and the central bronchial system. EBUS is mostly used for staging of lung cancer patients, but EBUS is now used worldwide as a diag......Endobronchial ultrasound (EBUS) is a minimally invasive diagnostic modality, by which it is possible to visualize and do biopsy of structures adjacent to the trachea and the central bronchial system. EBUS is mostly used for staging of lung cancer patients, but EBUS is now used worldwide...

  8. Telepathology and Optical Biopsy

    Directory of Open Access Journals (Sweden)

    Olga Ferrer-Roca

    2009-01-01

    Full Text Available The ability to obtain information about the structure of tissue without taking a sample for pathology has opened the way for new diagnostic techniques. The present paper reviews all currently available techniques capable of producing an optical biopsy, with or without morphological images. Most of these techniques are carried out by physicians who are not specialized in pathology and therefore not trained to interpret the results as a pathologist would. In these cases, the use of telepathology or distant consultation techniques is essential.

  9. No need for biopsies

    DEFF Research Database (Denmark)

    Gjødsbøl, Kristine; Skindersoe, Mette E; Christensen, Jens Jørgen

    2011-01-01

    collected. After 4 weeks, additional biopsy and filter paper pad samples were collected. Bacteria were isolated and identified at species level by standard methods. The most common bacterial species detected was Staphylococcus aureus found in 89% of the ulcers. No methicillin-resistant S. aureus isolates...... were found. We did not find any significant differences regarding the bacterial species isolated between the three sampling techniques. However, using multiple techniques led to identification of more species. Our study suggests that it is sufficient to use swab specimens to identify the bacterial...

  10. [A case of neuro-neutrophilic disease presenting with 5 months' with cognitive decline, meningoencephalitis, and marked systemic inflammatory findings, and diagnosed with brain biopsy].

    Science.gov (United States)

    Ohe, Yasuko; Nakazato, Yoshihiko; Ishizawa, Keisuke; Deguchi, Ichiro; Tamura, Naotoshi; Araki, Nobuo

    2011-01-01

    A 63-year-old man was admitted to our hospital with cognitive decline. On admission, he had a fever and mild cognitive dysfunction, suggesting chronic meningoencephalitis. Apart from a mild increase in serum C-reactive protein level and marked neutrophilia, laboratory findings were unremarkable. Brain magnetic resonance (MR) imaging showed multiple small T2-hyperintense lesions in the white matter. Systemic evaluations for infectious organisms, autoantibodies, and malignancy were all negative. For 5 months we conducted therapeutic trials of various antibacterial, antifungal, and antituberculous drugs, but these were completely ineffective, and both meningoencephalitis and inflammatory signs persisted. Repeated brain MRI during the clinical course showed growth of the white matter lesions and progressive cerebral atrophy. C11-methionine positron emission tomography demonstrated a bright focus in the right frontal lobe, and this was biopsied. Key neuropathological findings were neutrophilic infiltration in the subarachnoid space and the frontal lobe without necrotic angiitis. These findings confirmed the diagnosis of neuro-neutrophilic disease, although skin tissue findings characteristic of Sweet disease and a B51, B54, or Cw1 HLA-profile were absent. After intravenous bolus administration of steroid and prolonged oral steroid therapy, fever and inflammatory signs diminished and cognitive symptoms improved.

  11. Image-guided procedures in brain biopsy.

    Science.gov (United States)

    Fujita, K; Yanaka, K; Meguro, K; Narushima, K; Iguchi, M; Nakai, Y; Nose, T

    1999-07-01

    Image-guided procedures, such as computed tomography (CT)-guided stereotactic and ultrasound-guided methods, can assist neurosurgeons in localizing the relevant pathology. The characteristics of image-guided procedures are important for their appropriate use, especially in brain biopsy. This study reviewed the results of various image-guided brain biopsies to ascertain the advantages and disadvantages. Brain biopsies assisted by CT-guided stereotactic, ultrasound-guided, Neuronavigator-guided, and the combination of ultrasound and Neuronavigator-guided procedures were carried out in seven, eight, one, and three patients, respectively. Four patients underwent open biopsy without a guiding system. Twenty of 23 patients had a satisfactory diagnosis after the initial biopsy. Three patients failed to have a definitive diagnosis after the initial procedure, one due to insufficient volume sampling after CT-guided procedure, and two due to localization failure by ultrasound because the lesions were nonechogenic. All patients who underwent biopsy using the combination of ultrasound and Neuronavigator-guided methods had a satisfactory result. The CT-guided procedure provided an efficient method of approaching any intracranial target and was appropriate for the diagnosis of hypodense lesions, but tissue sampling was sometimes not sufficient to achieve a satisfactory diagnosis. The ultrasound-guided procedure was suitable for the investigation of hyperdense lesions, but was difficult to localize nonechogenic lesions. The combination of ultrasound and Neuronavigator methods improved the diagnostic accuracy even in nonechogenic lesions such as malignant lymphoma. Therefore, it is essential to choose the most appropriate guiding method for brain biopsy according to the radiological nature of the lesions.

  12. iPLA2β deficiency attenuates obesity and hepatic steatosis in ob/ob mice through hepatic fatty-acyl phospholipid remodeling.

    Science.gov (United States)

    Deng, Xiuling; Wang, Jiliang; Jiao, Li; Utaipan, Tanyarath; Tuma-Kellner, Sabine; Schmitz, Gerd; Liebisch, Gerhard; Stremmel, Wolfgang; Chamulitrat, Walee

    2016-05-01

    PLA2G6 or GVIA calcium-independent PLA2 (iPLA2β) is identified as one of the NAFLD modifier genes in humans, and thought to be a target for NAFLD therapy. iPLA2β is known to play a house-keeping role in phospholipid metabolism and remodeling. However, its role in NAFLD pathogenesis has not been supported by results obtained from high-fat feeding of iPLA2β-null (PKO) mice. Unlike livers of human NAFLD and genetically obese rodents, fatty liver induced by high-fat diet is not associated with depletion of hepatic phospholipids. We therefore tested whether iPLA2β could regulate obesity and hepatic steatosis in leptin-deficient mice by cross-breeding PKO with ob/ob mice to generate ob/ob-PKO mice. Here we observed an improvement in ob/ob-PKO mice with significant reduction in serum enzymes, lipids, glucose, insulin as well as improved glucose tolerance, and reduction in islet hyperplasia. The improvement in hepatic steatosis measured by liver triglycerides, fatty acids and cholesterol esters was associated with decreased expression of PPARγ and de novo lipogenesis genes, and the reversal of β-oxidation gene expression. Notably, ob/ob livers contained depleted levels of lysophospholipids and phospholipids, and iPLA2β deficiency in ob/ob-PKO livers lowers the former, but replenished the latter particularly phosphatidylethanolamine (PE) and phosphatidylcholine (PC) that contained arachidonic (AA) and docosahexaenoic (DHA) acids. Compared with WT livers, PKO livers also contained increased PE and PC containing AA and DHA. Thus, iPLA2β deficiency protected against obesity and ob/ob fatty liver which was associated with hepatic fatty-acyl phospholipid remodeling. Our results support the deleterious role of iPLA2β in severe obesity associated NAFLD. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Leptin Reduces the Expression and Increases the Phosphorylation of the Negative Regulators of GLUT4 Traffic TBC1D1 and TBC1D4 in Muscle of ob/ob Mice

    Science.gov (United States)

    Sáinz, Neira; Rodríguez, Amaia; Catalán, Victoria; Becerril, Sara; Ramírez, Beatriz; Lancha, Andoni; Burgos-Ramos, Emma; Gómez-Ambrosi, Javier; Frühbeck, Gema

    2012-01-01

    Leptin improves insulin sensitivity in skeletal muscle. Our goal was to determine whether proteins controlling GLUT4 traffic are altered by leptin deficiency and in vivo leptin administration in skeletal muscle of wild type and ob/ob mice. Leptin-deficient ob/ob mice were divided in three groups: control, leptin-treated (1 mg/kg/d) and leptin pair-fed ob/ob mice. Microarray analysis revealed that 1,546 and 1,127 genes were regulated by leptin deficiency and leptin treatment, respectively. Among these, we identified 24 genes involved in intracellular vesicle-mediated transport in ob/ob mice. TBC1 domain family, member 1 (Tbc1d1), a negative regulator of GLUT4 translocation, was up-regulated (P = 0.001) in ob/ob mice as compared to wild types. Importantly, leptin treatment reduced the transcript levels of Tbc1d1 (P<0.001) and Tbc1d4 (P = 0.004) in the leptin-treated ob/ob as compared to pair-fed ob/ob animals. In addition, phosphorylation levels of TBC1D1 and TBC1D4 were enhanced in leptin-treated ob/ob as compared to control ob/ob (P = 0.015 and P = 0.023, respectively) and pair-fed ob/ob (P = 0.036 and P = 0.034, respectively) mice. Despite similar GLUT4 protein expression in wild type and ob/ob groups a different immunolocalization of this protein was evidenced in muscle sections. Leptin treatment increased GLUT4 immunoreactivity in gastrocnemius and extensor digitorum longus sections of leptin-treated ob/ob mice. Moreover, GLUT4 protein detected in immunoprecipitates from TBC1D4 was reduced by leptin replacement compared to control ob/ob (P = 0.013) and pair-fed ob/ob (P = 0.037) mice. Our findings suggest that leptin enhances the intracellular GLUT4 transport in skeletal muscle of ob/ob animals by reducing the expression and activity of the negative regulators of GLUT4 traffic TBC1D1 and TBC1D4. PMID:22253718

  14. Radio observations of the CMa OB1 H II regions

    International Nuclear Information System (INIS)

    Gaylard, M.J.; Kemball, A.J.

    1984-01-01

    A sensitive 10 0 x 15 0 13-cm map made of the CMa OB1 H II regions' radio emission shows a strong similarity to Hα emission photographs. Sharpless 296 is shown to consist of a prominent central and western arc completed by a weaker southern loop, and with a faint northern bar. The emission is thermal, superimposed over a predominantly non-thermal background. The H142α recombination line has been detected at eight positions in S296, and in S292 and S297. The average electron temperature in S296 is 6900 +- 1300 K. The UV fluxes from the CMa OB1 stars account for the observed emission measures of the H II regions. The H142α 1sr velocities indicate that the ionized material is in contact with the molecular clouds. (author)

  15. Ultrasound-guided biopsy and drainage

    International Nuclear Information System (INIS)

    Ott, R.C.; Wellauer, J.

    1985-01-01

    This book discusses the ultrasound (US) biopsy techniques, cytology, histology, and physics. The emphasis is on use of US guidance, as the authors find that virtually all lesions are visible at US scanning and they thus save valuable time on the computer tomographic scanner. The authors present in great detail their considerable work in designing needles that are readily visible at US scanning and can also collect good cytologic and histologic material. Biopsy techniques are discussed separately for each organ system. The accuracy of these techniques in over 3,000 of the author's cases is presented

  16. Web-based thyroid imaging reporting and data system: Malignancy risk of atypia of undetermined significance or follicular lesion of undetermined significance thyroid nodules calculated by a combination of ultrasonography features and biopsy results.

    Science.gov (United States)

    Choi, Young Jun; Baek, Jung Hwan; Shin, Jung Hee; Shim, Woo Hyun; Kim, Seon-Ok; Lee, Won-Hong; Song, Dong Eun; Kim, Tae Yong; Chung, Ki-Wook; Lee, Jeong Hyun

    2018-05-13

    The purpose of this study was to construct a web-based predictive model using ultrasound characteristics and subcategorized biopsy results for thyroid nodules of atypia of undetermined significance/follicular lesion of undetermined significance (AUS/FLUS) to stratify the risk of malignancy. Data included 672 thyroid nodules from 656 patients from a historical cohort. We analyzed ultrasound images of thyroid nodules and biopsy results according to nuclear atypia and architectural atypia. Multivariate logistic regression analysis was performed to predict whether nodules were diagnosed as malignant or benign. The ultrasound features, including spiculated margin, marked hypoechogenicity, calcifications, biopsy results, and cytologic atypia, showed significant differences between groups. A 13-point risk scoring system was developed, and the area under the curve (AUC) of the receiver operating characteristic (ROC) curve of the development and validation sets were 0.837 and 0.830, respectively (http://www.gap.kr/thyroidnodule_b3.php). We devised a web-based predictive model using the combined information of ultrasound characteristics and biopsy results for AUS/FLUS thyroid nodules to stratify the malignant risk. © 2018 Wiley Periodicals, Inc.

  17. Neutral hydrogen in the stellar accociation Scorpius OB-2

    Energy Technology Data Exchange (ETDEWEB)

    Bystrova, N.V.

    1979-01-01

    The distribution of neutral hydrogen connected with the stellar association Scorpius OB-2 is more complex than the expanding semienvelope suggested earlier. The neutral gas is in connection with the nebulae S1, S7, S9 and with H/sub ..cap alpha../-filaments found in the association and giving it the appearence of a spiral galaxy. The HI-distribution is in disagreement with the model of a supernova remnant.

  18. CT Guided biopsies of musculoskeletal lesions, radiological and pathologic correlation

    International Nuclear Information System (INIS)

    Hadzihasanovic, B.; Milisic, L.; Zuban, J.; Mujic, E.; Jahic, E.; Gjikolli, B.; Hasanovic, B.; Lincender-Cvijetic, L.; Jaganjac, S.

    2006-01-01

    Full text: The aim of the study is to overview our experiences in taking the CT guided biopsies of musculoskeletal lesions during the period of sixteen months, analysis of validity of samples taken and correlation with pathological findings. CT guided biopsies of musculoskeletal lesions were performed in 32 patients during the period of sixteen months (from December 2004 until March 2006). Age range was from 13 to 78 years. Majorities of the biopsies were performed with coaxial cutting needle system (14 G and 16 G) with introducers size 13 and 15 G. Bone biopsies were performed with Yamsidi needles in purpose of taking the bone cylinder. Majorities of the biopsies were performed under local anaesthesia except a thirteen years old child to whom CT guided biopsy of corpus Th 6 was performed under general anaesthesia. Two samples of tissues were sent in formalin solutions to Pathology Institute for pathological verification. In one case of musculoskeletal lesions CT guided biopsies didn't yield a representative tissue sample. We had high level of congruence between radiological and pathological findings; precise presented in the article. CT guided biopsies of musculoskeletal lesions are method of choice for pathologic verification of musculoskeletal lesions proving incomparable less risk compared to 'open' biopsy which requires operating theatre and general anaesthesia. Coaxial needle systems has shown as suitable for yielding representative tissue samples (two samples for each patient), and samples are also appropriate for immunohistochemical analysis

  19. Variability of X-ray emission from OB stars

    International Nuclear Information System (INIS)

    Collura, A.; Sciortino, S.; Serio, S.; Vaiana, G. S.; Harnden, F.R. JR.; Osservatorio Astronomico, Palermo, Italy; Harvard-Smithsonian Center for Astrophysics, Cambridge, MA)

    1989-01-01

    The variability in soft X-ray emission of 12 OB stars is studied. Two different methods of analysis, one more suitable for detecting short-term variations, the other aimed at detecting long time-scale variations, are applied to all stars in the sample. The long-term variability analysis shows that Cyg-OB2 8A Zeta Pup and Delta Ori exhibit significant count rate variations between different data sections. Similar variations are marginally detected in 15 Mon; the count rate variations for the other eight stars are consistent with statistical fluctuations. The light curve of Cyg-OB2 8A suggests the existence of two different emission levels. The short-term variability analysis detects marginal variability in Tau Sco with an effective amplitude of about 30 percent and a time scale of about 50 s. The upper limits to the effective short-term variability amplitude for all other sample stars are in the 10-30 percent range. 30 refs

  20. ObsPy: A Python Toolbox for Seismology

    Science.gov (United States)

    Krischer, Lion; Megies, Tobias; Sales de Andrade, Elliott; Barsch, Robert; MacCarthy, Jonathan

    2017-04-01

    In recent years the Python ecosystem evolved into one of the most powerful and productive scientific environments across disciplines. ObsPy (https://www.obspy.org) is a fully community-driven, open-source project dedicated to providing a bridge for seismology into that ecosystem. It does so by offering Read and write support for essentially every commonly used data format in seismology with a unified interface and automatic format detection. This includes waveform data (MiniSEED, SAC, SEG-Y, Reftek, …) as well as station (SEED, StationXML, …) and event meta information (QuakeML, ZMAP, …). Integrated access to the largest data centers, web services, and real-time data streams (FDSNWS, ArcLink, SeedLink, ...). A powerful signal processing toolbox tuned to the specific needs of seismologists. Utility functionality like travel time calculations with the TauP method, geodetic functions, and data visualizations. ObsPy has been in constant development for more than seven years and is developed and used by scientists around the world with successful applications in all branches of seismology. Additionally it nowadays serves as the foundation for a large number of more specialized packages. This presentation will give a short overview of the capabilities of ObsPy and point out several representative or new use cases. Additionally we will discuss the road ahead as well as the long-term sustainability of open-source scientific software.

  1. Liver biopsy — the current view?

    African Journals Online (AJOL)

    needles, or the more recent cutting-core automated or semi-automated needles. These may be single units, or part of gun-type system with disposable needles. The pathologist's requirements of the specimen depend on whether diffuse disease or focal lesions are biopsied. The ideal tissue core for diffuse disease should be ...

  2. A simple classification system (the Tree flowchart) for breast MRI can reduce the number of unnecessary biopsies in MRI-only lesions

    Energy Technology Data Exchange (ETDEWEB)

    Woitek, Ramona; Spick, Claudio; Schernthaner, Melanie; Kapetas, Panagiotis; Bernathova, Maria; Furtner, Julia; Pinker, Katja; Helbich, Thomas H.; Baltzer, Pascal A.T. [Medical University of Vienna, Department of Biomedical Imaging and Image-Guided Therapy, Vienna (Austria); Rudas, Margaretha [Medical University of Vienna, Clinical Institute of Pathology, Vienna (Austria)

    2017-09-15

    To assess whether using the Tree flowchart obviates unnecessary magnetic resonance imaging (MRI)-guided biopsies in breast lesions only visible on MRI. This retrospective IRB-approved study evaluated consecutive suspicious (BI-RADS 4) breast lesions only visible on MRI that were referred to our institution for MRI-guided biopsy. All lesions were evaluated according to the Tree flowchart for breast MRI by experienced readers. The Tree flowchart is a decision rule that assigns levels of suspicion to specific combinations of diagnostic criteria. Receiver operating characteristic (ROC) curve analysis was used to evaluate diagnostic accuracy. To assess reproducibility by kappa statistics, a second reader rated a subset of 82 patients. There were 454 patients with 469 histopathologically verified lesions included (98 malignant, 371 benign lesions). The area under the curve (AUC) of the Tree flowchart was 0.873 (95% CI: 0.839-0.901). The inter-reader agreement was almost perfect (kappa: 0.944; 95% CI 0.889-0.998). ROC analysis revealed exclusively benign lesions if the Tree node was ≤2, potentially avoiding unnecessary biopsies in 103 cases (27.8%). Using the Tree flowchart in breast lesions only visible on MRI, more than 25% of biopsies could be avoided without missing any breast cancer. (orig.)

  3. A Multi-Fiber Spectroscopic Search for Low-mass Young Stars in Orion OB1

    Science.gov (United States)

    Loerincs, Jacqueline; Briceno, Cesar; Calvet, Nuria; Mateo, Mario L.; Hernandez, Jesus

    2017-01-01

    We present here results of a low resolution spectroscopic followup of candidate low-mass pre-main sequence stars in the Orion OB1 association. Our targets were selected from the CIDA Variability Survey of Orion (CVSO), and we used the Michigan/Magellan Fiber Spectrograph (M2FS) on the Magellan Clay 6.5m telescope to obtain spectra of 500 candidate T Tauri stars distributed in seven 0.5 deg diameter fields, adding to a total area of ~5.5 deg2. We identify young stars by looking at the distinctive Hα 6563 Å emission and Lithium Li I 6707 Å absorption features characteristic of young low mass pre-main sequence stars. Furthermore, by measuring the strength of their Hα emission lines, confirmed T Tauri stars can be classified as either Classical T Tauris (CTTS) or Weak-line T Tauris (WTTS), which give indication of whether the star is actively accreting material from a gas and dust disk surrounding the star, which may be the precursor of a planetary system. We confirm a total of 90 T Tauri stars, of which 50% are newly identified young members of Orion; out of the 49 new detections,15 are accreting CTTS, and of these all but one are found in the OB1b sub-region. This result is in line with our previous findings that this region is much younger than the more extended Orion OB1a sub-association. The M2FS results add to our growing census of young stars in Orion, that is allowing us to characterize in a systematic and consistent way the distribution of stellar ages across the entire complex, in order to building a complete picture of star formation in this, one of nearest most active sites of star birth.

  4. Evaluation of an endoscopic liver biopsy technique in green iguanas.

    Science.gov (United States)

    Hernandez-Divers, Stephen J; Stahl, Scott J; McBride, Michael; Stedman, Nancy L

    2007-06-15

    To establish a safe and effective endoscopic technique for collection of liver biopsy specimens from lizards by use of a 2.7-mm rigid endoscope system that is commonly available in zoologic veterinary practice. Prospective study. 11 subadult male green iguanas (Iguana iguana). Each lizard was anesthetized, and right-sided coelioscopic examination of the right liver lobe and gallbladder was performed. Three liver biopsy specimens were collected from each lizard by use of a 2.7-mm rigid endoscope and 1.7-mm (5-F) biopsy forceps. Biopsy samples were evaluated histologically for quality and crush artifact. Ten days following surgery, all iguanas were euthanatized and underwent full necropsy examination. For all 11 iguanas, the right liver lobe and gallbladder were successfully examined endoscopically, and 3 biopsy specimens of the liver were collected without complications. Mean +/- SD durations of anesthesia and surgery were 24 +/- 7 minutes and 6.8 +/- 1.0 minutes, respectively. At necropsy, there was no evidence of trauma or disease associated with the skin or muscle entry sites, liver, or any visceral structures in any iguana. All 33 biopsy specimens were considered acceptable for histologic interpretation; in most samples, the extent of crush artifact was considered minimal. By use of a 2.7-mm rigid endoscope, liver biopsy procedures can be performed safely, swiftly, and easily in green iguanas. Biopsy specimens obtained by this technique are suitable for histologic examination. For evaluation of the liver and biopsy specimen collection in lizards, endoscopy is recommended.

  5. Oral Biopsy: A Dental Gawk

    African Journals Online (AJOL)

    Sir,. Dermatologists are often confronted with neoplasms and diseases of the oral cavity. Although many may be reluctant to perform oral surgical procedures, a biopsy is often needed to establish a definitive diagnosis, and biopsy of the oral cavity is a safe and useful technique that can be easily employed by dermatologists.

  6. The accuracy of colposcopic biopsy

    DEFF Research Database (Denmark)

    Stoler, Mark H; Vichnin, Michelle D; Ferenczy, Alex

    2011-01-01

    We evaluated the overall agreement between colposcopically directed biopsies and the definitive excisional specimens within the context of three clinical trials. A total of 737 women aged 16-45 who had a cervical biopsy taken within 6 months before their definitive therapy were included. Per-prot...

  7. Predictive power of the ESUR scoring system for prostate cancer diagnosis verified with targeted MR-guided in-bore biopsy

    International Nuclear Information System (INIS)

    Schimmöller, L.; Quentin, M.; Arsov, C.; Hiester, A.; Kröpil, P.; Rabenalt, R.; Albers, P.; Antoch, G.; Blondin, D.

    2014-01-01

    Highlights: • The PI-RADS summed score (PS sum ) demonstrated very good diagnostic values, especially for higher grade PCa. • Lesions with PS sum ≥13 represented prostate cancer in 88% and higher grade prostate cancer in 42%. • Sensitivity and NPV was nearly 100% for higher grade PCa detection using a cut-off limit of PS sum 10. • Peripheral zone lesions demonstrated better diagnostic value with the PS sum compared to transitional zone lesions. • Further improvement of the PI-RADS score is required to prevent unnecessary overdiagnosis. - Abstract: Purpose: This study evaluates the diagnostic value of the ESUR scoring system (PI-RADS) regarding prostate cancer detection using MR-guided in-bore biopsies (IB-GB) as the reference standard. Methods: 566 lesions in 235 consecutive patients (65.7 ± 7.9 years, PSA 9.9 ± 8.5 ng/ml) with a multiparametric (mp)-MRI (T2WI, DWI, DCE) of the prostate at 3 T were scored using the PI-RADS scoring system. PI-RADS single (PS single ), summed (PS sum ), and overall (PS overall ) scores were determined. All lesions were histologically verified by IB-GB. Results: Lesions with a PS sum below 9 contained no prostate cancer (PCa) with Gleason score (GS) ≥ 4 + 3 = 7. A PS sum of 13–15 (PS overall V) resulted in 87.8% (n = 108) in PCa and in 42.3% (n = 52) in GS ≥ 4 + 3 = 7. Transition zone (TZ) lesions with a PS sum of 13–15 (PS overall V) resulted in 76.3% (n = 36) in PCa and in 26.3% (n = 10) in GS ≥ 4 + 3 = 7, whereas for peripheral zone (PZ) lesions cancer detection rate at this score was 92.9% (n = 79) and 49.4% (n = 42) for GS ≥ 4 + 3 = 7. Using a threshold of PS sum ≥ 10, sensitivity was 86.0%, and negative predictive value (NPV) was 86.2%. For higher grade PCa sensitivity was 98.6%, and NPV was 99.5%. Conclusion: A PS sum below 9 excluded a higher grade PCa, whereas lesions with a PS sum ≥ 13 (PS overall V) represented in 88% PCa, and in 42% higher grade PCa. The PS sum or PS overall demonstrated a

  8. As assessment of the flux of radionuclide contamination through the Ob and Yenisei rivers and estuaries to the Kara Sea

    International Nuclear Information System (INIS)

    Pauluszkiewicz, T.; Hibler, L.F.; Richmond, M.C.; Bradley, D.J.

    1995-01-01

    Recent data indicate that there are potentially large sources of radionuclide contamination on the Ob River system. To quantify the existing radionuclide contamination from a possible catastrophic event data and models have been used to quantify scenarios. Using a compilation of Russian data on the radionuclide contamination, hydrologic data and studies on the sediment transport process a conceptual model has been developed of the Ob system, and a numerical model has been applied to estimate the radionuclide flux to the Kara Sea. The initial results of the river modeling in the Mayak region show how important watershed flow from the marshes are to the hydrologic budget of the area. The preliminary analysis of the sediment flux indicates the need to consider the depositional (storage) regions such as the Asanow Marsh. 31 refs., 5 figs

  9. [Modeling of Processes of Migration and Accumulation of Radionuclides in Freshwater Ecosystems by the Example of the Samson, Lev, Vandras Rivers Related to the Ob-Irtysh River Basin].

    Science.gov (United States)

    Trapeznikov, A V; Korzhavin, A V; Trapeznikova, V N; Nikolkin, V N

    2016-01-01

    Mathematical models of horizontal distribution and migration of radionuclides are presented in water and floodplain soils of the Samson-Lev-Vandras river system related to the Ob-Irtysh river basin. Integral inventory of radionuclides in the main components of the river ecosystems is calculated. The estimated annual discharge of radionuclides from the Vandras river to the Great Salym river is given. The effect of the removal of man-made radionuclides in the Samson, Lev, Vandras rivers on radioactive contamination of the Ob-Irtysh river system is shown in comparison with the Techa river, that also belongs to the Ob-Irtysh river basin. Despite the presence of an additional radioactive contamination of the Samson floodplain, the transfer of radioactive substances in the Samson, Lev, Vandras rivers has a much smaller impact on the contamination of the Ob-Irtysh river system, compared to the Techa river, prone to a large-scale radioactive contamination.

  10. Diffuse reflectance imaging: a tool for guided biopsy

    Science.gov (United States)

    Jayanthi, Jayaraj L.; Subhash, Narayanan; Manju, Stephen; Nisha, Unni G.; Beena, Valappil T.

    2012-01-01

    Accurate diagnosis of premalignant or malignant oral lesions depends on the quality of the biopsy, adequate clinical information and correct interpretation of the biopsy results. The major clinical challenge is to precisely locate the biopsy site in a clinically suspicious lesion. Dips due to oxygenated hemoglobin absorption have been noticed at 545 and 575 nm in the diffusely reflected white light spectra of oral mucosa and the intensity ratio R545/R575 has been found suited for early detection of oral pre-cancers. A multi-spectral diffuse reflectance (DR) imaging system has been developed consisting of an electron multiplying charge coupled device (EMCCD) camera and a liquid crystal tunable filter for guiding the clinician to an optimal biopsy site. Towards this DR images were recorded from 27 patients with potentially malignant lesions on their tongue (dorsal, lateral and ventral sides) and from 44 healthy controls at 545 and 575 nm with the DR imaging system. False colored ratio image R545/R575 of the lesion provides a visual discerning capability that helps in locating the most malignant site for biopsy. Histopathological report of guided biopsy showed that out of the 27 patients 16 were cancers, 9 pre-cancers and 2 lichen planus. In this clinical trial DR imaging has correctly guided 25 biopsy sites, yielding a sensitivity of 93% and a specificity of 98%, thereby establishing the potential of DR imaging as a tool for guided biopsy.

  11. A Search for Pulsar Companions to OB Runaway Stars

    Science.gov (United States)

    Kaspi, V. M.

    1995-01-01

    We have searched for radio pulsar companions to 40 nearby OB runaway stars. Observations were made at 474 and 770 MHz with the NRAO 140 ft telescope. The survey was sensitive to long- period pulsars with flux densities of 1 mJy or more. One previously unknown pulsar was discovered, PSRJ2044+4614, while observing towards target O star BD+45,3260. Follow-up timing observations of the pulsar measured its position to high precision, revealing a 9' separation between the pulsar and the target star, unequivocally indicating they are not associated.

  12. ObsPy - A Python Toolbox for Seismology - and Applications

    Science.gov (United States)

    Krischer, L.; Megies, T.; Barsch, R.; MacCarthy, J.; Lecocq, T.; Koymans, M. R.; Carothers, L.; Eulenfeld, T.; Reyes, C. G.; Falco, N.; Sales de Andrade, E.

    2017-12-01

    Recent years witnessed the evolution of Python's ecosystem into one of the most powerful and productive scientific environments across disciplines. ObsPy (https://www.obspy.org) is a fully community driven, open-source project dedicated to provide a bridge for seismology into that ecosystem. It is a Python toolbox offering: Read and write support for essentially every commonly used data format in seismology with a unified interface and automatic format detection. This includes waveform data (MiniSEED, SAC, SEG-Y, Reftek, …) as well as station (SEED, StationXML, SC3ML, …) and event meta information (QuakeML, ZMAP, …). Integrated access to the largest data centers, web services, and real-time data streams (FDSNWS, ArcLink, SeedLink, ...). A powerful signal processing toolbox tuned to the specific needs of seismologists. Utility functionality like travel time calculations with the TauP method, geodetic functions, and data visualizations. ObsPy has been in constant development for more than eight years and is developed and used by scientists around the world with successful applications in all branches of seismology. Additionally it nowadays serves as the foundation for a large number of more specialized packages. Newest features include: Full interoperability of SEED and StationXML/Inventory objects Access to the Nominal Response Library (NRL) for easy and quick creation of station metadata from scratch Support for the IRIS Federated Catalog Service Improved performance of the EarthWorm client Several improvements to MiniSEED read/write module Improved plotting capabilities for PPSD (spectrograms, PSD of discrete frequencies over time, ..) Support for.. Reading ArcLink Inventory XML Reading Reftek data format Writing SeisComp3 ML (SC3ML) Writing StationTXT format This presentation will give a short overview of the capabilities of ObsPy and point out several representative or new use cases and show-case some projects that are based on ObsPy, e.g.: seismo

  13. Assessment of tissue fibrosis in skin biopsies from patients with systemic sclerosis employing confocal laser scanning microscopy: an objective outcome measure for clinical trials?

    Science.gov (United States)

    Busquets, Joanna; Del Galdo, Francesco; Kissin, Eugene Y.

    2010-01-01

    Objectives. To obtain an objective, unbiased assessment of skin fibrosis in patients with SSc for use in clinical trials of SSc disease-modifying therapeutics. Methods. Skin biopsies from the dorsal forearm of six patients with diffuse SSc and six healthy controls, and skin biopsies from the forearm of one patient with diffuse SSc before and following 1 year treatment with mycophenolate mofetil were analysed by confocal laser scanning microscopy (CLSM) with specific antibodies against collagen types I and III or fibronectin. The integrated density of fluorescence (IDF) was calculated employing National Institutes of Health-ImageJ software in at least four different fields per biopsy spanning the full dermal thickness. Results. The intensities of collagen types I and III and fibronectin IDF were 174, 147 and 139% higher in SSc skin than in normal skin, respectively. All differences were statistically significant. The sum of the IDF values obtained for the three proteins yielded a comprehensive fibrosis score. The average fibrosis score for the six SSc samples was 28.3 × 106 compared with 18.6 × 106 for the six normal skin samples (P < 0.0001). Comparison of skin biopsies obtained from the same SSc patient before treatment and after 12 months of treatment with mycophenolate mofetil showed a reduction of 39% in total fibrosis score after treatment. Conclusions. CLSM followed by quantitative image analysis provides an objective and unbiased assessment of skin fibrosis in SSc and could be a useful end-point for clinical trials with disease-modifying agents to monitor the response or progression of the disease. PMID:20202926

  14. Mammographic scar for stereotaxic biopsy

    International Nuclear Information System (INIS)

    Guzman Tattis; Hincapie U, Ana Lucia; Patino P, Jairo Hernando

    1997-01-01

    It is reported the case of 56 years old woman who underwent a stereotactic biopsy because of having a circumscribed breast nodule. The histologic diagnosis was benign. After six months, during the mammographic control, it was noticed that the nodule showed irregular contours, because of that a surgical biopsy was performed. The histopathology was reported as benign. it is considered then, that the mammographic changes observed in the mammographic control are due to scar phenomenon after stereotactic biopsy. This findings has not been reported previously

  15. The utilization of an ultrasound-guided 8-gauge vacuum-assisted breast biopsy system as an innovative approach to accomplishing complete eradication of multiple bilateral breast fibroadenomas

    Directory of Open Access Journals (Sweden)

    Povoski Stephen P

    2007-10-01

    Full Text Available Abstract Background Ultrasound-guided vacuum-assisted breast biopsy technology is extremely useful for diagnostic biopsy of suspicious breast lesions and for attempted complete excision of appropriately selected presumed benign breast lesions. Case presentation A female patient presented with 16 breast lesions (eight within each breast, documented on ultrasound and all presumed to be fibroadenomas. Over a ten and one-half month period of time, 14 of these 16 breast lesions were removed under ultrasound guidance during a total of 11 separate 8-gauge Mammotome® excision procedures performed during seven separate sessions. Additionally, two of these 16 breast lesions were removed by open surgical excision. A histopathologic diagnosis of fibroadenoma and/or fibroadenomatous changes was confirmed at all lesion excision sites. Interval follow-up ultrasound imaging revealed no evidence of a residual lesion at the site of any of the 16 original breast lesions. Conclusion This report describes an innovative approach of utilizing ultrasound-guided 8-gauge vacuum-assisted breast biopsy technology for assisting in achieving complete eradication of multiple bilateral fibroadenomas in a patient who presented with 16 documented breast lesions. As such, this innovative approach is highly recommended in similar appropriately selected patients.

  16. Repeated biopsies in prostate cancer patients on active surveillance

    DEFF Research Database (Denmark)

    Thomsen, Frederik Birkebaek; Marcussen, Niels; Berg, Kasper Drimer

    2015-01-01

    OBJECTIVE: To investigate the clinical implications of interobserver variation in the assessment of re-biopsies obtained during active surveillance (AS). MATERIAL AND METHODS: A total of 107 low-risk prostate cancer patients with a total of 93 diagnostic biopsy sets and 109 re-biopsy sets were...... included. The ISUP 2005 Gleason scoring system was applied for the histopathological assessment of all biopsies. Three different definitions of histopathological progression were applied. Unweighted and linear weighted Kappa statistics were used to compare the interobserver agreement. RESULTS: The overall...... recommendations would have changed in up to 10.1% (95% CI: 5.4%-17.7%) of the 109 re-biopsy sets. CONCLUSION: Kappa statistics demonstrated a strong agreement between the histological evaluations. Still, up to 10% of AS patients would receive different treatment recommendation depending upon which...

  17. Modelling of slag emulsification and slag reduction in CAS-OB process

    OpenAIRE

    Sulasalmi, P. (Petri)

    2016-01-01

    Abstract Composition Adjustment by Sealed argon bubbling – Oxygen Blowing (CAS-OB) process is a ladle treatment process that was developed for chemical heating and alloying of steel. The main stages of the process are heating, (possible) alloying and reduction of slag. The CAS-OB process aims for homogenization and control of the composition and temperature of steel. In this dissertation, a mathematical reaction model was developed for the slag reduction stage of the CAS-OB process. Sl...

  18. The Seismic Broad Band Western Mediterranean (wm) Network and the Obs Fomar Pool: Current state and Obs activities.

    Science.gov (United States)

    Pazos, Antonio; Davila, Jose Martin; Buforn, Elisa; Bezzeghoud, Mourad; Harnafi, Mimoun; Mattesini, Mauricio; Caldeira, Bento; Hanka, Winfried; El Moudnib, Lahcen; Strollo, Angelo; Roca, Antoni; Lopez de Mesa, Mireya; Dahm, Torsten; Cabieces, Roberto

    2016-04-01

    The Western Mediterranean (WM) seismic network started in 1996 as an initiative of the Royal Spanish Navy Observatory (ROA) and the Universidad Complutense de Madrid (UCM), with the collaboration of the GeoForschungsZentrum (GFZ) of Potsdam. A first broad band seismic station (SFUC) was installed close to Cádiz (South Spain). Since then, additional stations have been installed in the Ibero-Moghrebian region. In 2005, the "WM" code was assigned by the FDSN and new partners were jointed: Evora University (UEVO, Portugal), the Scientifique Institute of Rabat (ISRABAT, Morocco), and GFZ. Now days, the WM network is composed by 15 BB stations, all of them with Streckaisen STS-2 or STS-2.5 sensors, Quanterra or Earthdata digitizers and SeiscomP. Most them have co-installed a permanent geodetic GPS stations, and some them also have an accelerometer. There are 10 stations deployed in Spanish territory (5 in the Iberian peninsula, 1 in Balearic islands and 4 in North Africa Spanish places) with VSAT or Internet communications, 2 in Portugal (one of them without real time), and 3 in Morocco (2 VSAT and 1 ADSL). Additionally, 2 more stations (one in South Spain and one in Morocco) will be installed along this year. Additionally ROA has deployed a permanent real time VBB (CMG-3T: 360s) station at the Alboran Island. Due to the fact that part of the seismic activity is located at marine areas, and also because of the poor geographic azimuthal coverage at some zones provided by the land stations (specially in the SW of the San Vicente Cape area), ROA and UCM have acquired six broad band "LOBSTERN" OBS, manufactured by KUM (Kiel, Germany), conforming the OBS FOMAR pool. Three of them with CMG-40T sensor and the other with Trillium 120. These OBS were deployed along the Gibraltar strait since January to November 2014 to study the microseismicity in the Gibraltar strait area. In September 2015 FOMAR network has been deployed in SW of the San Vicente Cape for 8 months as a part of

  19. Dietary Capsaicin Improves Glucose Homeostasis and Alters the Gut Microbiota in Obese Diabetic ob/ob Mice

    Directory of Open Access Journals (Sweden)

    Jun-Xian Song

    2017-08-01

    Full Text Available Background: The effects of capsaicin on obesity and glucose homeostasis are still controversial and the mechanisms underlying these effects remain largely unknown. This study aimed to investigate the potential relationship between the regulation of obesity and glucose homeostasis by dietary capsaicin and the alterations of gut microbiota in obese diabetic ob/ob mice.Methods: The ob/ob mice were subjected to a normal, low-capsaicin (0.01%, or high-capsaicin (0.02% diet for 6 weeks, respectively. Obesity phenotypes, glucose homeostasis, the gut microbiota structure and composition, short-chain fatty acids, gastrointestinal hormones, and pro-inflammatory cytokines were measured.Results: Both the low- and high-capsaicin diets failed to prevent the increase in body weight, adiposity index, and Lee's obesity index. However, dietary capsaicin at both the low and high doses significantly inhibited the increase of fasting blood glucose and insulin levels. These inhibitory effects were comparable between the two groups. Similarly, dietary capsaicin resulted in remarkable improvement in glucose and insulin tolerance. In addition, neither the low- nor high-capsaicin diet could alter the α-diversity and β-diversity of the gut microbiota. Taxonomy-based analysis showed that both the low- and high-capsaicin diets, acting in similar ways, significantly increased the Firmicutes/Bacteroidetes ratio at the phylum level as well as increased the Roseburia abundance and decreased the Bacteroides and Parabacteroides abundances at the genus level. Spearman's correlation analysis revealed that the Roseburia abundance was negatively while the Bacteroides and Parabacteroides abundances were positively correlated to the fasting blood glucose level and area under the curve by the oral glucose tolerance test. Finally, the low- and high-capsaicin diets significantly increased the fecal butyrate and plasma total GLP-1 levels, but decreased plasma total ghrelin, TNF-α, IL-1

  20. Ultrasound-Guided Breast Biopsy

    Science.gov (United States)

    ... over time. top of page What are the benefits vs. risks? Benefits The procedure is less invasive than surgical biopsy, ... risk of infection. The chance of infection requiring antibiotic treatment appears to be less than one in ...

  1. X-ray guided biopsy

    International Nuclear Information System (INIS)

    Casanova, R.; Lezana, A.H.; Pedrosa, C.S.

    1980-01-01

    Fine needle aspiration biopsy (FNAB) is now a routine procedure in many X-ray Departments. This paper presents the authors' experience with this technique in chest, abdominal and skeletal lesions. (Auth.)

  2. Stereotactic (Mammographically Guided) Breast Biopsy

    Science.gov (United States)

    ... over time. top of page What are the benefits vs. risks? Benefits The procedure is less invasive than surgical biopsy, ... risk of infection. The chance of infection requiring antibiotic treatment appears to be less than one in ...

  3. Testicular biopsy in prepubertal boys

    DEFF Research Database (Denmark)

    Faure, Alice; Bouty, Aurore; O'Brien, Mike

    2016-01-01

    No consensus exists regarding the precise role of testicular biopsy in prepubertal boys, although it is considered useful for assessing the potential consequences of undescended testes on fertility. Current scientific knowledge indicates that surgeons should broaden indications for this procedure...... for the preservation of fertility after gonadotoxic chemotherapy - even for prepubertal boys - are emerging. Cryopreservation of testicular tissue samples for the preservation of fertility - although still an experimental method at present - is appealing in this context. In our opinion, testicular biopsy...

  4. Predictive power of the ESUR scoring system for prostate cancer diagnosis verified with targeted MR-guided in-bore biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Schimmöller, L., E-mail: Lars.Schimmoeller@med.uni-duesseldorf.de [Univ Dusseldorf, Medical Faculty, Department of Diagnostic and Interventional Radiology, Moorenstr. 5, D-40225 Dusseldorf (Germany); Quentin, M., E-mail: Michael.Quentin@med.uni-duesseldorf.de [Univ Dusseldorf, Medical Faculty, Department of Diagnostic and Interventional Radiology, Moorenstr. 5, D-40225 Dusseldorf (Germany); Arsov, C., E-mail: Cristian.Arsov@med.uni-duesseldorf.de [Univ Dusseldorf, Medical Faculty, Department of Urology, Moorenstr. 5, D-40225 Dusseldorf (Germany); Hiester, A., E-mail: Andreas.Hiester@med.uni-duesseldorf.de [Univ Dusseldorf, Medical Faculty, Department of Urology, Moorenstr. 5, D-40225 Dusseldorf (Germany); Kröpil, P., E-mail: Patric.Kroepil@med.uni-duesseldorf.de [Univ Dusseldorf, Medical Faculty, Department of Diagnostic and Interventional Radiology, Moorenstr. 5, D-40225 Dusseldorf (Germany); Rabenalt, R., E-mail: Robert.Rabenalt@med.uni-duesseldorf.de [Univ Dusseldorf, Medical Faculty, Department of Urology, Moorenstr. 5, D-40225 Dusseldorf (Germany); Albers, P., E-mail: urologie@uni-duesseldorf.de [Univ Dusseldorf, Medical Faculty, Department of Urology, Moorenstr. 5, D-40225 Dusseldorf (Germany); Antoch, G., E-mail: Antoch@med.uni-duesseldorf.de [Univ Dusseldorf, Medical Faculty, Department of Diagnostic and Interventional Radiology, Moorenstr. 5, D-40225 Dusseldorf (Germany); Blondin, D., E-mail: Dirk.Blondin@sk-mg.de [Univ Dusseldorf, Medical Faculty, Department of Diagnostic and Interventional Radiology, Moorenstr. 5, D-40225 Dusseldorf (Germany)

    2014-12-15

    Highlights: • The PI-RADS summed score (PS{sub sum}) demonstrated very good diagnostic values, especially for higher grade PCa. • Lesions with PS{sub sum} ≥13 represented prostate cancer in 88% and higher grade prostate cancer in 42%. • Sensitivity and NPV was nearly 100% for higher grade PCa detection using a cut-off limit of PS{sub sum} 10. • Peripheral zone lesions demonstrated better diagnostic value with the PS{sub sum} compared to transitional zone lesions. • Further improvement of the PI-RADS score is required to prevent unnecessary overdiagnosis. - Abstract: Purpose: This study evaluates the diagnostic value of the ESUR scoring system (PI-RADS) regarding prostate cancer detection using MR-guided in-bore biopsies (IB-GB) as the reference standard. Methods: 566 lesions in 235 consecutive patients (65.7 ± 7.9 years, PSA 9.9 ± 8.5 ng/ml) with a multiparametric (mp)-MRI (T2WI, DWI, DCE) of the prostate at 3 T were scored using the PI-RADS scoring system. PI-RADS single (PS{sub single}), summed (PS{sub sum}), and overall (PS{sub overall}) scores were determined. All lesions were histologically verified by IB-GB. Results: Lesions with a PS{sub sum} below 9 contained no prostate cancer (PCa) with Gleason score (GS) ≥ 4 + 3 = 7. A PS{sub sum} of 13–15 (PS{sub overall} V) resulted in 87.8% (n = 108) in PCa and in 42.3% (n = 52) in GS ≥ 4 + 3 = 7. Transition zone (TZ) lesions with a PS{sub sum} of 13–15 (PS{sub overall} V) resulted in 76.3% (n = 36) in PCa and in 26.3% (n = 10) in GS ≥ 4 + 3 = 7, whereas for peripheral zone (PZ) lesions cancer detection rate at this score was 92.9% (n = 79) and 49.4% (n = 42) for GS ≥ 4 + 3 = 7. Using a threshold of PS{sub sum} ≥ 10, sensitivity was 86.0%, and negative predictive value (NPV) was 86.2%. For higher grade PCa sensitivity was 98.6%, and NPV was 99.5%. Conclusion: A PS{sub sum} below 9 excluded a higher grade PCa, whereas lesions with a PS{sub sum} ≥ 13 (PS{sub overall} V) represented in 88

  5. Sonographically guided percutaneous muscle biopsy in diagnosis of neuromuscular disease: a useful alternative to open surgical biopsy.

    Science.gov (United States)

    O'Sullivan, Paul J; Gorman, Grainne M; Hardiman, Orla M; Farrell, Michael J; Logan, P Mark

    2006-01-01

    The purpose of this study was to evaluate the feasibility of sonographically guided percutaneous muscle biopsy in the investigation of neuromuscular disorders. Sonographically guided percutaneous needle biopsy of skeletal muscle was performed with a 14-gauge core biopsy system in 40 patients over a 24-month period. Patients were referred from the Department of Neurology under investigation for neuromuscular disorders. Sonography was used to find suitable tissue and to avoid major vascular structures. A local anesthetic was applied below skin only. A 3- to 4-mm incision was made. Three 14-gauge samples were obtained from each patient. All samples were placed on saline-dampened gauze and sent for neuropathologic analysis. As a control, we retrospectively assessed results of the 40 most recent muscle samples acquired via open surgical biopsy. With the use of sonography, 32 (80%) of 40 patients had a histologic diagnosis made via percutaneous needle biopsy. This included 26 (93%) of 28 patients with acute muscular disease and 6 (50%) of 12 patients with chronic disease. In the surgical group (all acute disease), 38 (95%) of 40 patients had diagnostic tissue attained. Sonographically guided percutaneous 14-gauge core skeletal muscle biopsy is a useful procedure, facilitating diagnosis in acute muscular disease. It provides results comparable with those of open surgical biopsy in acute muscular disease. It may also be used in chronic muscular disease but repeated or open biopsy may be needed.

  6. Decreased triiodothyronine receptor binding in skeletal muscle nuclei and erythrocyte membranes of obese (ob/ob) mice

    International Nuclear Information System (INIS)

    Gilvary, E.P.

    1988-01-01

    Hindlimb skeletal muscle weights and binding of L-tri-iodothyronine (T 3 ) to isolated nuclei of this tissue were investigated in obese (ob/ob) mice and their lean littermates. Maximal binding capacities (Bmax) and dissociation constants (Kd) were determined by incubating isolated muscle nuclei with increasing conc. of 125 I-T 3 (0.4 nM to 4nM). At 12 wks. of age, although weighing substantially more, obese mice had only 55% as much muscle mass as their lean littermates. There was no phenotype effect observed for Kd, however, Bmax was significantly less for the obese mice. In a second experiment, a 16-wk. feeding study was conducted with 4 groups of mice according to the following design: lean mice fed rodent chow; obese mice fed rodent chow; obese mice, n-6 fatty acid (FA)-rich diet; and obese mice, n-3FA-rich diet. Erythrocyte T 3 receptor binding capacities were measured by incubating red cell ghosts from mice of these 4 groups with 125 I-T 3 . As with skeletal muscle nuclei there were no phenotype effects observed for Kd between any two groups. In contrasts obese mice fed chow and n-6FA-rich diets both exhibited lower Bmax than their lean counterparts, while no significant difference was observed between the latter group and the obese mice fed an n-3FA-rich diet. Bmax values of the n-6 group were also decreased compared to the n-3 group

  7. Mammotome HH biopsy - the future of minimal invasive breast surgery?

    International Nuclear Information System (INIS)

    Pietrzyk, G.; Nowicki, J.; Bojarski, B.; Kedzierski, B.; Wysocki, A.; Prudlak, E.

    2007-01-01

    Vacuum-assisted breast biopsy / Mammotome HH '' R '' Breast Biopsy System/ is the milestone in the diagnosis of breast lesions. This system has proven to be as diagnostically reliable as open surgery, but without scarring, deformations and hospitalizations associated with an open procedure. The aim of our study was to assess the role and possibilities of using this biopsy in treatment of benign breast lesions like fibroadenoma. From 2001 to 2004, about 1118 Mammotome biopsies were performed in our Department. Among 445 Mammotome biopsies performed under US control there were 211 cases of fibroadenomas. Follow-up was performed in 156 patients with this result at 6 and 12 months after biopsy. In our study we took into considerations the size, localizations as well as performers. In 2002 there were 70.8% patients with total lesion excision, 16.7% with residual lesion and 12.5% women with hematomas or scars. In 2003-2004 there were more women with total lesion excision (84.3%), fewer residual tumors and other lesions. In future, Mammotome breast biopsy can replace scalpel, and will become an alternative method to open surgical excision of fibroadenomas. It is important especially in the cases of young women to prevent cosmetic deformations and scars. (author)

  8. Oral delivery of [D-Leu-4]-OB3 and MA-[D-Leu-4]-OB3, synthetic peptide leptin mimetics: Immunofluorescent localization in the mouse hypothalamus.

    Science.gov (United States)

    Anderson, Brian M; Jacobson, Lauren; Novakovic, Zachary M; Grasso, Patricia

    2017-06-01

    This study describes the localization of [D-Leu-4]-OB3 and MA-[D-Leu-4]-OB3, synthetic peptide leptin mimetics, in the hypothalamus of Swiss Webster and C57BL/6J wild-type mice, leptin-deficient ob/ob mice, and leptin-resistant diet-induced obese (DIO) mice. The mice were given [D-Leu-4]-OB3 or MA-[D-Leu-4]-OB3 in 0.3% dodecyl maltoside by oral gavage. Once peak serum concentrations were reached, the mice received a lethal dose of pentobarbital and were subjected to intracardiac perfusion fixation. The brains were excised, post-fixed in paraformaldehyde, and cryo-protected in sucrose. Free-floating frozen coronal sections were cut at 25-µm and processed for imaging by immunofluorescence microscopy. In all four strains of mice, dense staining was concentrated in the area of the median eminence, at the base and/or along the inner wall of the third ventricle, and in the brain parenchyma at the level of the arcuate nucleus. These results indicate that [D-Leu-4]-OB3 and MA-[D-Leu-4]-OB3 cross the blood-brain barrier and concentrate in an area of the hypothalamus known to regulate energy balance and glucose homeostasis. Most noteworthy is the localization of [D-Leu-4]-OB3 immunoreactivity within the hypothalamus of DIO mice via a conduit that is closed to leptin in this rodent model, and in most cases of human obesity. Together with our previous studies describing the effects of [D-Leu-4]-OB3 and MA-[D-Leu-4]-OB3 on energy balance, glucose regulation, and signal transduction pathway activation, these findings are consistent with a central mechanism of action for these synthetic peptide leptin mimetics, and suggest their potential usefulness in the management of leptin-resistant obesity and type 2 diabetes in humans. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Ultrasound-guided forceps for pleural biopsy

    Directory of Open Access Journals (Sweden)

    Gamal Agmy

    2014-04-01

    Clinical implications: Ultrasound-guided forceps for pleural biopsy can overcome many of the limitations of the conventional needle biopsy procedures, provides multiple biopsy specimens of the parietal pleura that are inaccessible to the biopsy needle, and can be carried out easily and safely even in sick and obese patients. The diagnostic yield is nearly similar to thoracoscopy.

  10. Mass loss rates of OB stars derived from infrared observations

    International Nuclear Information System (INIS)

    Tanzi, E.G.; Tarenghi, M.; Panagia, N.

    1981-01-01

    In this paper the authors report briefly on a study of the mass loss of early type stars in the infrared. Up to now near infrared (1.25 - 4.8 μ) broad band photometry of 70 southern OB stars of various luminosity class has been secured. Program stars have been selected, among those bright enough in the infrared to give a suitable photometric accuracy, in order to cover a wide range of spectral types. 37 stars are found to exhibit emission in excess over a blackbody photospheric continuum, which is interpreted in terms of gas ejected in the form of an accelerated wind. By means of model calculations the corresponding mass loss rates are derived. The obtained values compare well with those determined independently by various authors for stars in common. Their data show that mass loss rates increase with luminosity and are a decreasing function of surface gravity. (Auth.)

  11. Dropping Probability Reduction in OBS Networks: A Simple Approach

    KAUST Repository

    Elrasad, Amr

    2016-08-01

    In this paper, we propose and derive a slotted-time model for analyzing the burst blocking probability in Optical Burst Switched (OBS) networks. We evaluated the immediate and delayed signaling reservation schemes. The proposed model compares the performance of both just-in-time (JIT) and just-enough-time (JET) signaling protocols associated with of void/non-void filling link scheduling schemes. It also considers none and limited range wavelength conversions scenarios. Our model is distinguished by being adaptable to different offset-time and burst length distributions. We observed that applying a limited range of wavelength conversion, burst blocking probability is reduced by several orders of magnitudes and yields a better burst delivery ratio compared with full wavelength conversion.

  12. Performance analysis of signaling protocols on OBS switches

    Science.gov (United States)

    Kirci, Pinar; Zaim, A. Halim

    2005-10-01

    In this paper, Just-In-Time (JIT), Just-Enough-Time (JET) and Horizon signalling schemes for Optical Burst Switched Networks (OBS) are presented. These signaling schemes run over a core dWDM network and a network architecture based on Optical Burst Switches (OBS) is proposed to support IP, ATM and Burst traffic. In IP and ATM traffic several packets are assembled in a single packet called burst and the burst contention is handled by burst dropping. The burst length distribution in IP traffic is arbitrary between 0 and 1, and is fixed in ATM traffic at 0,5. Burst traffic on the other hand is arbitrary between 1 and 5. The Setup and Setup ack length distributions are arbitrary. We apply the Poisson model with rate λ and Self-Similar model with pareto distribution rate α to identify inter-arrival times in these protocols. We consider a communication between a source client node and a destination client node over an ingress and one or more multiple intermediate switches.We use buffering only in the ingress node. The communication is based on single burst connections in which, the connection is set up just before sending a burst and then closed as soon as the burst is sent. Our analysis accounts for several important parameters, including the burst setup, burst setup ack, keepalive messages and the optical switching protocol. We compare the performance of the three signalling schemes on the network under as burst dropping probability under a range of network scenarios.

  13. Observations of mass loss from OB and Wolf-Rayet stars

    International Nuclear Information System (INIS)

    Barlow, M.J.

    1982-01-01

    In this review, three observationally accessible parameters of the winds of OB and Wolf-Rayet stars are discussed: (1) Terminal velocities, (2) Velocity laws, (3) Mass loss rates. In addition, some discussion of the ionisation structure of the winds is included. In general, only the most recent results for OB stars are mentioned. (Auth.)

  14. Ocular Manifestations of Biopsy-Proven Pulmonary Sarcoidosis in Korea

    Directory of Open Access Journals (Sweden)

    Seung Yong Choi

    2018-01-01

    Full Text Available Purpose. To investigate the clinical features and ocular manifestations of biopsy-proven pulmonary sarcoidosis in Korea. Methods. 55 patients diagnosed with pulmonary sarcoidosis by bronchoscopic or excisional biopsy were included. By retrospective clinical chart review, we investigated features of uveitis, ocular and systemic treatments, visual acuity, angiotensin-converting enzyme level, chest radiography, and pulmonary function tests. Clinical features were analyzed by presence of uveitis, site of biopsy, and first manifested sign of sarcoidosis. Results. The group with uveitis (n=39 presented with higher systemic (71.8% and immunosuppressive treatment rates (35.9% than the group without uveitis (31.3%, 0%, resp. (P=0.007, P=0.005, resp.. There were no significant differences in clinical features, including systemic treatment rate, by type of biopsy. Of 39 patients with uveitis, the group with ocular manifestation as a first sign of sarcoidosis showed higher systemic and immunosuppressive treatment rates (88.9%, 55.6% compared to the group with pulmonary manifestation as a first sign (57.1%, 19.0% (P=0.037, P=0.018, resp.. Conclusions. In patients with biopsy-proven pulmonary sarcoidosis, the presence of ocular involvement and uveitis as a first sign could be significant factors associated with higher systemic treatment rate, especially with immunosuppressive agents. Biopsy site determined by location and size had no influence on clinical features.

  15. Are breast biopsies adequately funded? A process cost and revenue analysis

    International Nuclear Information System (INIS)

    Hahn, M.; Fischbach, E.; Fehm, T.

    2011-01-01

    Purpose: The objective of the study was to determine whether the various breast biopsy procedures specified in the S 3 guidelines are sensibly represented within the current German health system as considered from a cost evaluation perspective. Materials and Methods: This prospectively designed multicenter study analyzed 221 breast biopsies at 7 institutions from 04/2006 to 01/2007. Core needle biopsies, vacuum-assisted biopsies and surgical open biopsies under sonographic or mammographic guidance were evaluated. During an analysis of process costs, the individual process steps were recorded in diagrammatic form and assigned to the true consumption of resources. The actual resource consumption costs were entered. A process-related breakeven analysis was conducted to check whether the reimbursement of individual biopsy types covers the costs. Results: Only sonographically guided core needle biopsy and surgical open biopsy are adequately reimbursed in the current German health system. All other breast biopsies indicate a negative profit margin. The principal reasons for underfunding are found in the area of reimbursement of investment and non-personnel costs. Conclusion: The reimbursement of breast biopsies must be improved in order to guarantee nationwide care of the population using the breast biopsy methods recommended in the S 3 guidelines and to avoid disincentives with respect to breast biopsy indications. (orig.)

  16. Tissue Biopsies in Diabetes Research

    DEFF Research Database (Denmark)

    Højlund, Kurt; Gaster, Michael; Beck-Nielsen, Henning

    2007-01-01

    resistance of glucose disposal and glycogen synthesis in this tissue are hallmark features of type 2 diabetes in humans (2,3). During the past two decades, we have carried out more than 1200 needle biopsies of skeletal muscle to study the cellular mechanisms underlying insulin resistance in type 2 diabetes....... Together with morphological studies, measurement of energy stores and metabolites, enzyme activity and phosphorylation, gene and protein expression in skeletal muscle biopsies have revealed a variety of cellular abnormalities in patients with type 2 diabetes and prediabetes. The possibility to establish...... and gene expression profiling on skeletal muscle biopsies have pointed to abnormalities in mitochondrial oxidative phosphorylation in type 2 diabetes. These novel insights will inevitably cause a renewed interest in studying skeletal muscle. This chapter reviews our experience to date and gives a thorough...

  17. Variable millimetre radiation from the colliding-wind binary Cygnus OB2 #8A

    Science.gov (United States)

    Blomme, R.; Fenech, D. M.; Prinja, R. K.; Pittard, J. M.; Morford, J. C.

    2017-12-01

    Context. Massive binaries have stellar winds that collide. In the colliding-wind region, various physically interesting processes occur, leading to enhanced X-ray emission, non-thermal radio emission, as well as non-thermal X-rays and gamma-rays. Non-thermal radio emission (due to synchrotron radiation) has so far been observed at centimetre wavelengths. At millimetre wavelengths, the stellar winds and the colliding-wind region emit more thermal free-free radiation, and it is expected that any non-thermal contribution will be difficult or impossible to detect. Aims: We aim to determine if the material in the colliding-wind region contributes substantially to the observed millimetre fluxes of a colliding-wind binary. We also try to distinguish the synchrotron emission from the free-free emission. Methods: We monitored the massive binary Cyg OB2 #8A at 3 mm with the NOrthern Extended Millimeter Array (NOEMA) interferometer of the Institut de Radioastronomie Millimétrique (IRAM). The data were collected in 14 separate observing runs (in 2014 and 2016), and provide good coverage of the orbital period. Results: The observed millimetre fluxes range between 1.1 and 2.3 mJy, and show phase-locked variability, clearly indicating that a large part of the emission is due to the colliding-wind region. A simple synchrotron model gives fluxes with the correct order of magnitude, but with a maximum that is phase-shifted with respect to the observations. Qualitatively this phase shift can be explained by our neglect of orbital motion on the shape of the colliding-wind region. A model using only free-free emission results in only a slightly worse explanation of the observations. Additionally, on the map of our observations we also detect the O6.5 III star Cyg OB2 #8B, for which we determine a 3 mm flux of 0.21 ± 0.033 mJy. Conclusions: The question of whether synchrotron radiation or free-free emission dominates the millimetre fluxes of Cyg OB2 #8A remains open. More detailed

  18. Release and transport of artificial radionuclides from nuclear weapons related activities in the Ob River, Siberia over the course of the nuclear age

    International Nuclear Information System (INIS)

    Sayles, F.L.; Kenna, T.C.; Livingston, H.D.

    1999-01-01

    Studies of sediment cores from lakes on the flood plain of the Ob River, Siberia have been used to develop a history of the release, transport, and deposition of artificial radionuclides related to the development and testing of nuclear weapons over the duration of the nuclear age (∼1950 to the present) in this major Arctic river system. The Ob is of particular importance in this regard as two of the former Soviet Union's major weapons production plants, Mayak and Tomsk-7, and the Semipalatinsk test site are located within the Ob drainage basin. Accidents and intentional releases of radionuclides at both plants have been substantial, raising the issue of transport throughout this extensive river system as well as delivery to the Arctic Ocean. Our studies have included determining sediment profiles of 239,240 Pu, 137 Cs, and the natural nuclide 210 Pb and its parent 226 Ra in a number of cores from the Ob delta, as well as analysis of 239 Pu, 240 Pu, and 237 Np. The latter provide sensitive measures of the presence of non-fallout materials derived from weapons production activities

  19. Biopsy techniques for intraocular tumors

    Directory of Open Access Journals (Sweden)

    Pukhraj Rishi

    2016-01-01

    Full Text Available Biopsy involves the surgical removal of a tissue specimen for histopathologic evaluation. Most intraocular tumors are reliably diagnosed based on the clinical evaluation or with noninvasive diagnostic techniques. However, accurately diagnosing a small percentage of tumors can be challenging. A tissue biopsy is thus needed to establish a definitive diagnosis and plan the requisite treatment. From fine-needle aspiration biopsy (FNAB to surgical excision, all tissue collection techniques have been studied in the literature. Each technique has its indications and limitations. FNAB has been reported to provide for 88-95% reliable and safe ophthalmic tumor diagnosis and has gained popularity for prognostic purposes and providing eye conserving treatment surgeries. The technique and instrumentation for biopsy vary depending upon the tissue involved (retina, choroid, subretinal space, vitreous, and aqueous, suspected diagnosis, size, location, associated retinal detachment, and clarity of the media. The cytopathologist confers a very important role in diagnosis and their assistance plays a key role in managing and planning the treatment for malignancies.

  20. Gastric tissue biopsy and culture

    Science.gov (United States)

    ... symptoms may include: Loss of appetite or weight loss Nausea and vomiting Pain in the upper part of the belly Black stools Vomiting blood or coffee ground-like material A gastric tissue biopsy and culture can help detect: Cancer Infections, most commonly Helicobacter ...

  1. The Role of Biopsy in Pediatric Dermatopathology

    Directory of Open Access Journals (Sweden)

    Fatma Şule Afşa

    2011-09-01

    Full Text Available Background and Design: Pediatric dermatology is characterized by skin disorders which have frequencies different from those in adults. Skin biopsies are necessary for differential diagnosis and clinicopathologic correlation is very important. The aim of this study was to evaluate retrospectively the pediatric dermatology cases in whom biopsy was performed for differential diagnosis and to investigate the contribution of biopsy to diagnosis of skin disorders. Material and Methods: The cases from whom biopsy was taken in the pediatric dermatology clinic during a three-year period were evaluated retrospectively for pre-diagnoses, biopsy diagnoses, and success of biopsies.Results: Two hundred thirteen (1.7% skin biopsies had been taken from a total of 12420 patients. Henoch-Schönlein purpura, psoriasis, pityriasis lichenoides, pityriasis rosea, lichen planus, pityriasis rubra pilaris, erythema multiforme, atopic dermatitis, granuloma annulare, and pigmented purpuric dermatosis were the most frequent skin disorders diagnosed dermatopathologically. In a total of 120 (56.3% cases, the biopsy diagnosis was within the pre-diagnosis and a biopsy consistency was present. In 25 (11.7% cases, biopsy had no contribution to the differential diagnosis. An absolutely different diagnosis which was incompatible with the pre-diagnosis had been reported in 10 (4.6% cases. Conclusion: In pediatric dermatology, skin biopsy is very helpful for the differential diagnosis. An easy biopsy procedure for the patient, an effective designation of biopsy indication, a good dermatopathologic correlation and an experienced team of pediatric dermatopathology increase the success of skin biopsies.

  2. New Partner Recruitment to Rural Versus Urban Ob-Gyn Practices

    Directory of Open Access Journals (Sweden)

    Michael F. Fialkow

    2017-09-01

    Full Text Available Purpose: The purpose of this pilot study was to investigate the recruitment efforts of practicing obstetrics and gynecology (ob-gyns from rural and urban practices. Method: The authors surveyed practicing ob-gyns from 5 states in the Pacific Northwest in 2016 about their background, practice setting, practice profile, partner recruitment, and retention. Results: Seventy-three patients completed the study (53.2% response rate. Thirty-seven percent of respondents work in an urban practice and 43% have a rural practice, with the remainder in a suburban setting. A majority of the respondents attempted to recruit a new partner in the past 5 years. Respondents were most interested in experience and diversity in new recruits. Urban respondents, however, were more interested in hiring those with specialized skills (χ 2 = 7.842, P = .02 than rural providers who were more interested in partners familiar with their community (χ 2 = 7.153, P = .03. Reasons most often cited to leave their practice were reimbursement, limited social/marital options, and workload, other than rural providers who more often also cited lack of access to specialty care (χ 2 = 13.256, P = .001. Rural providers were more likely to cite marital and family status as an advantage to recruitment, whereas urban and suburban providers were more often neutral. Conclusions: Reduced access to care has led to significant health disparities for women living in rural communities. Understanding which providers are most likely to be successful in these settings might help preserve access as our health-care systems evolves.

  3. Retroperitoneoscopic renal biopsy in children

    Directory of Open Access Journals (Sweden)

    Carlos M. Jesus

    2007-08-01

    Full Text Available OBJECTIVE: We present our experience in a series of 17 consecutive pediatric patients submitted to retroperitoneal laparoscopic renal biopsy. MATERIALS AND METHODS: Retroperitoneal laparoscopic renal biopsy (LRB was performed in 5 boys and 12 girls. Mean age was 8.1 years and age range from 2 to 12. Two or three trocars were used to expose the inferior pole of the kidney, remove enough cortical parenchymal specimen and fulgurate the biopsy site. Assessment included surgical time, estimated blood loss, hospitalization period, analgesia requirements, complications and number of glomeruli present in the specimen. RESULTS: LRB was successfully performed in all 15 patients (88%. In two cases, LRB was not possible to be performed. One patient was converted to a transperitoneal laparoscopy due to tear in the peritoneum. The other patient had had previous abdominal surgery and, during retroperitoneal balloon dilation, the peritoneum was opened and the open biopsy was performed. A third patient had postoperatively a perirenal hematoma, which was solved spontaneously. Complication rate was 17.6% (3/17 cases. Mean operative time was 65 minutes, while mean estimated blood loss was 52 mL, mean hospital stay was 2.2 days and mean analgesic requirement was 100 mg of tramadol. The mean number of glomeruli present in the specimen was 60. CONCLUSION: Retroperitoneal laparoscopic renal biopsy in children is a simple, safe. Bleeding is still the most common complication. However, direct vision usually allows a safe control of this drawback. In our institution, laparoscopic approach is the chosen procedure in pediatric patients older than one - year - old.

  4. Biopsy results of Bosniak 2F and 3 cystic lesions

    DEFF Research Database (Denmark)

    Rasmussen, René; Hørlyck, Arne; Nielsen, Tommy Kjærgaard

    be helpful in clinical decisions. Material and Methods: From March 2013 - December 2014 a total of 295 percutaneous ultrasound guided biopsies from 287 patients with a suspected malignant renal lesion were performed at our institution. All cases were reviewed in PACS by (RR) and lesions presenting...... with a cystic change were re-evaluated and re-categorized after the Bosniak classification system. The re-evaluation and re-categorization was performed in consensus by a junior radiologist (RR) and an uro-radiological expert (OG). Results: Biopsies from eighteen Bosniak 2F cystic lesions were pathologically...... analyzed and three (17%) proved to be malignant. Biopsies from seventeen Bosniak 3 cystic lesions were pathologically analyzed and five (29%) were found to be malignant. Conclusion: Our results reveal a considerable malignancy rate among both Bosniak 2F and 3 cystic renal lesions. Biopsy seems...

  5. CT-guided biopsies and drainage

    International Nuclear Information System (INIS)

    Scheppers, I.; Wollschlaeger, D.

    2011-01-01

    Following the implementation of computed tomography (CT) or ultrasound-guided biopsy of solid tumors and the puncture and drainage of liquid processes, the number of surgical open biopsies and curative operations for abscess drainage has declined. Such CT-guided interventions are performed in nearly every organ. Instead of aspiration biopsies, more and more core biopsies are being performed to allow histopathological evaluation and thus allowing targeted therapy. This article is intended to give a general overview of techniques, materials, indications and contraindications. Ultrasound-guided biopsies as well as large bore vacuum biopsies of the breast are not included in this review. (orig.) [de

  6. Freehand biopsy guided by electromagnetic needle tracking

    DEFF Research Database (Denmark)

    Ewertsen, C; Nielsen, Marie Kristina Rue; Nielsen, M Bachmann

    2011-01-01

    To evaluate the overall accuracy and time spent on biopsy guided by electromagnetic needle tracking in a phantom compared with the standard technique of US-guided biopsy with an attached steering device. Furthermore, to evaluate off-plane biopsy guided by needle tracking.......To evaluate the overall accuracy and time spent on biopsy guided by electromagnetic needle tracking in a phantom compared with the standard technique of US-guided biopsy with an attached steering device. Furthermore, to evaluate off-plane biopsy guided by needle tracking....

  7. On the Binary Nature of Massive Blue Hypergiants: High-resolution X-Ray Spectroscopy Suggests That Cyg OB2 12 is a Colliding Wind Binary

    Energy Technology Data Exchange (ETDEWEB)

    Oskinova, L. M.; Hamann, W.-R.; Shenar, T.; Sander, A. A. C.; Todt, H.; Hainich, R. [Institute for Physics and Astronomy, University Potsdam, D-14476 Potsdam (Germany); Huenemoerder, D. P. [Massachusetts Institute of Technology, Kavli Institute for Astrophysics and Space Research, 70 Vassar St., Cambridge, MA 02139 (United States); Ignace, R., E-mail: lida@astro.physik.uni-potsdam.de [Department of Physics and Astronomy, East Tennessee State University, Johnson City, TN 37663 (United States)

    2017-08-10

    The blue hypergiant Cyg OB2 12 (B3Ia{sup +}) is a representative member of the class of very massive stars in a poorly understood evolutionary stage. We obtained its high-resolution X-ray spectrum using the Chandra observatory. PoWR model atmospheres were calculated to provide realistic wind opacities and to establish the wind density structure. We find that collisional de-excitation is the dominant mechanism depopulating the metastable upper levels of the forbidden lines of the He-like ions Si xiv and Mg xii. Comparison between the model and observations reveals that X-ray emission is produced in a dense plasma, which could reside only at the photosphere or in a colliding wind zone between binary components. The observed X-ray spectra are well-fitted by thermal plasma models, with average temperatures in excess of 10 MK. The wind speed in Cyg OB2 12 is not high enough to power such high temperatures, but the collision of two winds in a binary system can be sufficient. We used archival data to investigate the X-ray properties of other blue hypergiants. In general, stars of this class are not detected as X-ray sources. We suggest that our new Chandra observations of Cyg OB2 12 can be best explained if Cyg OB2 12 is a colliding wind binary possessing a late O-type companion. This makes Cyg OB2 12 only the second binary system among the 16 known Galactic hypergiants. This low binary fraction indicates that the blue hypergiants are likely products of massive binary evolution during which they either accreted a significant amount of mass or already merged with their companions.

  8. COSMIC ORIGINS SPECTROGRAPH OBSERVATIONS OF TRANSLUCENT CLOUDS: Cyg OB2 8A

    International Nuclear Information System (INIS)

    Snow, Theodore P.; Destree, Joshua D.; Burgh, Eric B.; Ferguson, Ryan M.; Danforth, Charles W.; Cordiner, Martin

    2010-01-01

    Data from the Cosmic Origins Spectrograph (COS) are presented for the first highly reddened target (Cyg OB2 8A) under the COS Science Team's guaranteed time allocation. Column densities of ionic, atomic, and molecular species are reported and implications are discussed. Data from Cyg OB2 8A demonstrate the ability to analyze highly reddened interstellar sight lines with the COS that were unavailable to previous UV instruments. Measured column densities indicate that the Cyg OB2 8A line of sight contains multiple diffuse clouds rather than a dominant translucent cloud.

  9. New Parallaxes for the Upper Scorpius OB Association

    Science.gov (United States)

    Donaldson, J. K.; Weinberger, A. J.; Gagné, J.; Boss, A. P.; Keiser, S. A.

    2017-11-01

    Upper Scorpius is a subgroup of the nearest OB association, Scorpius-Centaurus. Its young age makes it an important association to study star and planet formation. We present parallaxes to 52 low-mass stars in Upper Scorpius, 28 of which have full kinematics. We measure ages of the individual stars by combining our measured parallaxes with pre-main-sequence evolutionary tracks. We find a significant difference in the ages of stars with and without circumstellar disks. The stars without disks have a mean age of 4.9 ± 0.8 Myr and those with disks have an older mean age of 8.2 ± 0.9 Myr. This somewhat counterintuitive result suggests that evolutionary effects in young stars can dominate their apparent ages. We also attempt to use the 28 stars with full kinematics (I.e., proper motion, radial velocity (RV), and parallax) to trace the stars back in time to their original birthplace to obtain a trackback age. As expected, given the large measurement uncertainties on available RV measurements, we find that measurement uncertainties alone cause the group to diverge after a few Myr.

  10. Study of clumping in the Cepheus OB 3 molecular cloud

    International Nuclear Information System (INIS)

    Carr, J.S.

    1987-01-01

    A portion of the Cep OB 3 molecular cloud has been mapped in the (C-13)O (1-0) line on a completely sampled grid with a 1.5-arcmin spacing. A total of 45 individual clouds, or clumps, have been identified in the map, with masses from 3 to 300 solar mass, sizes 3 pc or smaller, and mean densities of a few hundred/cu cm. Power-law correlations are found among the clump properties, namely, M proportional to R exp 2.5 and Delta(v) exp 0.24. These exponents differ somewhat from those found for similar correlations for molecular clouds in previous studies. Determination of the virial masses for the clumps shows that the clumps are not gravitationally bound and must be expanding on a time scale of about 1 Myr. Measurements of the (C-13)O (2-1) line give volume densities of 2000-5000. Comparisons of these densities with the mean volume densities from the (C-13)O (1-0) data suggest that the gas is clumped on a small scale with a volume filling factor of 0.04-0.10. 31 references

  11. A Novel Congestion Detection Scheme in TCP Over OBS Networks

    KAUST Repository

    Shihada, Basem

    2009-02-01

    This paper introduces a novel congestion detection scheme for high-bandwidth TCP flows over optical burst switching (OBS) networks, called statistical additive increase multiplicative decrease (SAIMD). SAIMD maintains and analyzes a number of previous round-trip time (RTTs) at the TCP senders in order to identify the confidence with which a packet loss event is due to network congestion. The confidence is derived by positioning short-term RTT in the spectrum of long-term historical RTTs. The derived confidence corresponding to the packet loss is then taken in the developed policy for TCP congestion window adjustment. We will show through extensive simulation that the proposed scheme can effectively solve the false congestion detection problem and significantly outperform the conventional TCP counterparts without losing fairness. The advantages gained in our scheme are at the expense of introducing more overhead in the SAIMD TCP senders. Based on the proposed congestion control algorithm, a throughput model is formulated, and is further verified by simulation results.

  12. Cost Analysis of Channeled, Distal Chip Laryngoscope for In-office Laryngopharyngeal Biopsies.

    Science.gov (United States)

    Marcus, Sonya; Timen, Micah; Dion, Gregory R; Fritz, Mark A; Branski, Ryan C; Amin, Milan R

    2018-02-19

    Given that financial considerations play an increasingly prominent role in clinical decision-making, we sought (1) to determine the cost-effectiveness of in-office biopsy for the patient, the provider, and the health-care system, and (2) to determine the diagnostic accuracy of in-office biopsy. Retrospective, financial analyses were performed. Patients who underwent in-office (Current Procedural Terminology Code 31576) or operative biopsy (CPT Code 31535) for laryngopharyngeal lesions were included. Two financial analyses were performed: (1) the average cost of operating room (OR) versus in-office biopsy was calculated, and (2) a break-even analysis was calculated to determine the cost-effectiveness of in-office biopsy for the provider. In addition, the diagnostic accuracy of in-office biopsies and need for additional biopsies or procedures was recorded. Of the 48 patients included in the current study, 28 underwent in-office biopsy. A pathologic sample was obtained in 26 of 28 (92.9%) biopsies performed in the office. Of these patients, 16 avoided subsequent OR procedures. The average per patient cost was $7000 and $11,000 for in-office and OR biopsy, respectively. Break-even analysis demonstrated that the provider could achieve a profit 2 years after purchase of the necessary equipment. In-office laryngopharyngeal biopsies are accurate and, overall, more cost-effective than OR biopsies. Purchase of the channeled, distal chip laryngoscope and biopsy forceps to perform in-office biopsies can be profitable for a provider with a videolaryngoscopy tower. In-office biopsy should be considered the initial diagnostic tool for suspected laryngopharyngeal malignancies noted on videolaryngoscopy. Copyright © 2018 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  13. Diagnostic accuracy of pre-treatment biopsy for grading cutaneous mast cell tumours in dogs.

    Science.gov (United States)

    Shaw, T; Kudnig, S T; Firestone, S M

    2018-06-01

    Mast cell tumours (MCTs) are common tumours of the canine skin, and are estimated to represent up to 20% of all skin tumours in dogs. Tumour grade has a major impact on the incidence of local recurrence and metastatic potential. In addition to helping the clinician with surgical planning, knowledge of the tumour grade also assists in proper prognostication and client education. For pre-treatment biopsies to be useful, there must exist a high level of correlation between the histopathological grade obtained from the pre-treatment biopsy and the actual histopathological grade from the excisional biopsy. The aim of this study was to determine concordance of tumour grade between various biopsy techniques (wedge, punch, needle core) and the "gold standard" excisional biopsy method. We found an overall concordance rate of 96% based on the Patnaik grading system, and an overall concordance rate of 92% based on the Kiupel grading system. The accuracy of the various biopsy techniques (wedge, punch and needle core) when compared with excisional biopsy was 92%, 100% and 100%, respectively, based on the Patnaik grading system, and 90%, 95% and 100%, respectively, based on the Kiupel grading system. Of the cases with discordant results, the pre-treatment biopsies tended to underestimate the grade of the tumour. Based on these results, we conclude that pre-treatment biopsies are sufficiently accurate for differentiating low-grade from high-grade MCTs, regardless of biopsy technique or tumour location. © 2017 John Wiley & Sons Ltd.

  14. Ultrasound guided percutaneous fine needle aspiration biopsy ...

    African Journals Online (AJOL)

    )-guided percutaneous fine needle aspiration biopsy (PFNAB)/US-guided percutaneous needle core biopsy (PNCB) of abdominal lesions is efficacious in diagnosis, is helpful in treatment choice, to evaluate whether various other investigations ...

  15. Right Ventricular Pseudoaneurysm Following Endomyocardial Biopsy.

    Science.gov (United States)

    Pita; Santos; Manteiga; Rodriguez; Beiras

    1996-03-01

    Ventricular perforation is an unusual complication after endomyocardial biopsy in heart transplanted patients. We report a case of asymptomatic right ventricular perforation and pseudoaneurysm formation, secondary to endomyocardial biopsy, diagnosed by angiography. The spontaneous obliteration of the pseudoaneurysm was observed.

  16. Bone biopsy needles. Mechanical properties, needle design and specimen quality

    International Nuclear Information System (INIS)

    Keulers, Annika; Penzkofer, T.; Cunha-Cruz, V.C.; Bruners, P.; Helmholtz Inst. fuer biomedizinische Technik, Aachen; Braunschweig, T.; Schmitz-Rode, T.; Mahnken, A.; Helmholtz Inst. fuer biomedizinische Technik, Aachen

    2011-01-01

    To quantitatively analyze differences in mechanical properties, needle design including signs of wear, subjective handling and specimen quality of bone biopsy needles. Materials and Methods: In this study 19 different bone biopsy systems (total 38; 2 /type) were examined. With each biopsy needle five consecutive samples were obtained from vertebral bodies of swine. During puncture a force-torques sensor measured the mechanical properties and subjective handling was assessed. Before and after each biopsy the needles were investigated using a profile projector and signs of wear were recorded. Afterwards, a pathologist semi-quantitatively examined the specimen regarding sample quality. The overall evaluation considered mechanical properties, needle wear, subjective handling and sample quality. Differences were assessed for statistical significance using ANOVA and t-test. Results: Needle diameter (p = 0.003) as well as needle design (p = 0.008) affect the mechanical properties significantly. Franseen design is significantly superior to other needle designs. Besides, length reduction recorded by the profile projector, as a quality criterion showed notable distinctions in between the needle designs. Conclusion: Bone biopsy needles vary significantly in performance. Needle design has an important influence on mechanical properties, handling and specimen quality. Detailed knowledge of those parameters would improve selecting the appropriate bone biopsy needle. (orig.)

  17. MR-guided preoperative localization and percutaneous core biopsy of suspicious breast lesions - experience on the vertically open 0.5 T system; MRT-gestuetzte Markierung und Stanzbiopsie suspekter Mammalaesionen. Moeglichkeiten und Erfahrungen an einem vertikal offenen 0,5-T-System

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, J.P.; Schulz, T.; Rueger, S.; Schmidt, F.; Kahn, T. [Universitaetsklinikum Leipzig (Germany). Klinik und Poliklinik fuer Diagnostische Radiologie; Horn, L.C. [Inst. fuer Pathologie, Universitaetsklinikum Leipzig (Germany); Leinung, S. [Chirurgische Klinik I, Universitaetsklinikum Leipzig (Germany); Briest, S. [Frauenklinik, Universitaetsklinikum Leipzig (Germany)

    2002-01-01

    Purpose. To evaluate the feasibility of performing breast interventions in a vertically open 0.5 T MR system (SIGNA SP/i, GE Medical Systems). To develop fitted equipment and to establish preoperative wire localization and percutaneous breast core biopsy as clinical routine procedures. Patients and methods. Initially, we applied a localization method with the patient placed in a sitting position in 31 cases using a single loop coil and a self-developed fixation device. Subsequently, 46 wire localizations and 28 percutaneous core biopsies were carried out in prone patient position using an open breast coil with an integrated biopsy device. The used instruments were either MR-compatible (18 G biopsy needle and localization wire, 14 G coaxial needle, prototype of a 16 G double-shoot gun) or MR-safe (double-shoot gun with 16 G needle). Results. After biopsy we found the needle tip (18 G for a wire localization and 14 G for a percutaneous core biopsy, respectively) placed either within or close to the lesions (<10 mm distance) for all patients. Out of a total of 66 benign lesions and 39 malignant tumors we missed the lesion (12 mm mean diameter, 4-25 mm range) during open biopsy in two cases and obtained a false negative result for one percutaneous biopsy of a 5 mm lesion. Conclusion. Preoperative wire localization and percutaneous core biopsy of suspicious breast lesions demonstrated by MRI can be carried out in a vertically open 0.5 T MR scanner. The degree of accuracy is comparable with that of X-ray or ultrasound-guided procedures. A follow-up has to be performed in cases with a negative biopsy. (orig.) [German] Zielsetzung. In den letzten Jahren wurde eine Vielzahl von Systemen zur praeoperativen Markierung oder Biopsie MRT-suspekter Mammalaesionen vorgestellt. Ziel unserer Untersuchungen war es, Moeglichkeiten solcher Verfahren an einem vertikal offenen 0,5-T-Magneten (SIGNA SP/i, GE Medical Systems) zu entwickeln, zu erproben und in die klinische Routine zu

  18. Neuronavigator-guided cerebral biopsy.

    Science.gov (United States)

    Koivukangas, J; Louhisalmi, Y; Alakuijala, J; Oikarinen, J

    1993-01-01

    Neuronavigators are new dynamic interactive instruments that use on-line computers to orient imaging data to the surgical field and guide the neurosurgeon to his target. We have been working since 1987 on a neuronavigator that serves not only as a precise pointer, but also as a dynamic arm that can be used to hold instruments, such as biopsy guides. The neuronavigator arm consists of six joints with optical encoders and is attached to the Mayfield headholder. The arm is connected to a workstation running customized 3D image graphics software. Special instruments and surgical technique have been developed. Here, we report on early clinical experience with ten biopsy procedures: 4 low-grade and 3 high-grade astrocytomas, one craniopharyngioma and one chronic intracerebral haematoma and intracerebral cyst, both of the latter with surrounding tumour suspect tissue. In all glioma cases serial biopsies were taken from optimal sites under ultrasound imaging control. Eight cases showed representative tumour tissue, while in two cases neoplasia was ruled out. The neuronavigator proved to be versatile, allowing comprehensive imaging data to be adapted to the surgical field.

  19. Aortography following subdiaphragmal aortic biopsy

    International Nuclear Information System (INIS)

    Schimmler, J.

    1982-01-01

    A juxtaposition of the subdiaphragmal and infrarenal translumbar aortic biopsy sites showed decisive advantages in favour of the higher site: a more stable position because of better anatomic fixation and rarer incidence of vascular alterations, a wider vascular lumen. Disadvantages lie in the fact that the large visceral arteries (especially Tr. coeliacus) branch off nearly and in the close anatomic relationship to large abdominal organs and the thoracal region. Evaluation of the radiographical image of the vascular tree after subdiaphragmal aortic biopsy showed an average 82% of the vessels to the area of the Knees to be assessable (renal arteries approximately 93%, popliteal arteries approximately 70%). Beyong, the method proved unsatisfactory: 52% of the vessels could not, or not safety, be evaluated. A relatively broad spectrum of indications by comparison with transfemoral catheter aortography had no influence on the rate of complications with reference to either method. A comparison of the topographic conditions shows the need for even more scrupulons observation of the technique in subdiaphragmal biopsy than in the infrarenal one. To sum up the results obtained, subdiaphregmal translumbar aortography is to be preferred to the infrarenal one where transfemoral catheter aortography is contra-indicated, within the limits mentioned. (orig.) [de

  20. Outcomes following negative prostate biopsy for patients with persistent disease after radiotherapy for prostate cancer

    Directory of Open Access Journals (Sweden)

    Jacob H. Cohen

    2010-02-01

    Full Text Available PURPOSE: When faced with biochemical recurrence after definitive radiotherapy for prostate cancer, clinicians must determine whether the recurrence is local or systemic. Post radiotherapy prostate biopsies to detect persistent local disease are difficult to interpret histopathologically and are subject to sampling error. Our study examines outcomes for patients with a negative prostate biopsy performed for rising prostate-specific antigen (PSA levels after prostate radiation. MATERIALS AND METHODS: We performed a retrospective review of 238 prostate cancer patients with a negative biopsy following definitive radiotherapy. Seventy-five of these patients had biochemical recurrence at the time of biopsy. A negative biopsy was defined as the absence of prostate cancer without radiation-treatment effect in the specimen. RESULTS: Patients underwent biopsy at a mean of 41 months after the completion of radiation. They had a mean PSA of 6. Patients were followed for an average of 63 months. Thirty-two patients (43% developed metastasis, and 11 (15% died of prostate cancer despite a negative post-radiation biopsy. Five of nine patients (56% with sequential biopsies had a positive second biopsy. CONCLUSIONS: Patients with PSA recurrence and a negative post-radiation biopsy have a high chance of persistent local disease, progression, and death from prostate cancer. Furthermore, an initial negative biopsy does not rule-out local recurrence. Patients with biochemical recurrence after radiotherapy for prostate cancer need to be evaluated earlier for local recurrence.

  1. Freehand biopsy guided by electromagnetic needle tracking

    DEFF Research Database (Denmark)

    Ewertsen, C; Nielsen, Marie Kristina Rue; Nielsen, M Bachmann

    2011-01-01

    To evaluate the overall accuracy and time spent on biopsy guided by electromagnetic needle tracking in a phantom compared with the standard technique of US-guided biopsy with an attached steering device. Furthermore, to evaluate off-plane biopsy guided by needle tracking....

  2. 20 CFR 718.106 - Autopsy; biopsy.

    Science.gov (United States)

    2010-04-01

    ... 20 Employees' Benefits 3 2010-04-01 2010-04-01 false Autopsy; biopsy. 718.106 Section 718.106... PNEUMOCONIOSIS Criteria for the Development of Medical Evidence § 718.106 Autopsy; biopsy. (a) A report of an autopsy or biopsy submitted in connection with a claim shall include a detailed gross macroscopic and...

  3. CT Fluoroscopy-Guided Lung Biopsy with Novel Steerable Biopsy Canula: Ex-Vivo Evaluation in Ventilated Porcine Lung Explants

    International Nuclear Information System (INIS)

    Schaefer, Philipp J.; Fabel, Michael; Bolte, Hendrik; Schaefer, Fritz K. W.; Jahnke, Thomas; Heller, Martin; Lammer, Johannes; Biederer, Juergen

    2010-01-01

    The purpose was to evaluate ex-vivo a prototype of a novel biopsy canula under CT fluoroscopy-guidance in ventilated porcine lung explants in respiratory motion simulations. Using an established chest phantom for porcine lung explants, n = 24 artificial lesions consisting of a fat-wax-Lipiodol mixture (approx. 70HU) were placed adjacent to sensible structures such as aorta, pericardium, diaphragm, bronchus and pulmonary artery. A piston pump connected to a reservoir beneath a flexible silicone reconstruction of a diaphragm simulated respiratory motion by rhythmic inflation and deflation of 1.5 L water. As biopsy device an 18-gauge prototype biopsy canula with a lancet-like, helically bended cutting edge was used. The artificial lesions were punctured under CT fluoroscopy-guidance (SOMATOM Sensation 64, Siemens, Erlangen, Germany; 30mAs/120 kV/5 mm slice thickness) implementing a dedicated protocol for CT fluoroscopy-guided lung biopsy. The mean-diameter of the artificial lesions was 8.3 ± 2.6 mm, and the mean-distance of the phantom wall to the lesions was 54.1 ± 13.5 mm. The mean-displacement of the lesions by respiratory motion was 14.1 ± 4.0 mm. The mean-duration of CT fluoroscopy was 9.6 ± 5.1 s. On a 4-point scale (1 = central; 2 = peripheral; 3 = marginal; 4 = off target), the mean-targeted precision was 1.9 ± 0.9. No misplacement of the biopsy canula affecting adjacent structures could be detected. The novel steerable biopsy canula proved to be efficient in the ex-vivo set-up. The chest phantom enabling respiratory motion and the steerable biopsy canula offer a feasible ex-vivo system for evaluating and training CT fluoroscopy-guided lung biopsy adapted to respiratory motion.

  4. Magnetic resonance imaging-guided biopsies may improve diagnosis in biopsy-naive men with suspicion of prostate cancer

    DEFF Research Database (Denmark)

    Winther, Mads Dochedahl; Balslev, Ingegerd; Boesen, Lars

    2017-01-01

    INTRODUCTION: The purpose of this pilot study was to investigate whether a short prostate biparametric magnetic resonance imaging (bp-MRI) protocol provides a valuable diagnostic addition for biopsy guidance in biopsy-naive men with a suspicion of prostate cancer (PCa). METHODS: A total of 62...... biopsy-naive patients referred to a systematic transrectal ultrasound biopsy (TRUS-bx) due to suspicion of PCa were prospectively enrolled. Bp-MRI was performed before biopsy. All lesions were scored according to the modified Prostate Imaging Reporting and Data System (PI-RADS) version 2. All patients...... underwent TRUS-bx followed by bp-MRI-guided biopsies (bp-MRI-bx) under MRI/TRUS image fusion from any bp-MRI suspicious lesions not obviously targeted by TRUS-bx. RESULTS: PCa was found in 42 (68%) and 32 (52%) patients by TRUS-bx and bp-MRI-bx, respectively. Bp-MRI-bx de-tected PCa in one patient who had...

  5. Multicenter study for the evaluation of a dedicated biopsy device for MR-guided vacuum biopsy of the breast

    International Nuclear Information System (INIS)

    Perlet, C.; Sittek, H.; Schneider, P.; Reiser, M.; Heinig, A.; Stets, C.; Heywang-Koebrunner, S.H.; Prat, X.; Lamarque, J.; Taourel, P.; Casselman, J.; Baath, L.; Anderson, I.

    2002-01-01

    The purpose of this multicenter study was to determine the accuracy and clinical value of a dedicated breast biopsy system which allows for MR-guided vacuum biopsy (VB) of contrast-enhancing lesions. In five European centers, MR-guided 11-gauge VB was performed on 341 lesions. In 7 cases VB was unsuccessful. This was immediately realized on postinterventional images or direct follow-up combined with histopathology-imaging correlation; thus, a false-negative diagnosis was avoided. Histology of 334 successful biopsies yielded 84 (25%) malignancies, 17 (5%) atypical ductal hyperplasias, and 233 (70%) benign entities. Verification of malignant or borderline lesions included reexcision of the biopsy cavity. Benign histologic biopsy results were verified by retrospective correlation with the pre- and postinterventional MRI and by subsequent follow-up. Our results indicate that MR-guided VB, in combination with the dedicated biopsy coil, offers the possibility to accurately diagnose even very small lesions that can only be visualized or localized by MRI. (orig.)

  6. [Detection of psychosocial dysfunction in ob-gyn patients].

    Science.gov (United States)

    González-Forteza, C F; Morales Carmona, F; Gutiérrez Calderon, E

    1993-01-01

    The human behavior and its social determinants are critical variables for understanding the etiology, treatment, and prevention of many disorders previously attributed to biological substrates. Among the many categories of human behavior to receive special attention from health researchers and practitioners are life events, coping responses and emotional state. The relation between these categories constituted a particular field of investigation. This relationship rather than forcing to focus on disease, distress, disability, and other failures in human functioning, permits to address health, abilities, resources, and other positive aspects of human functioning. On the other hand, the re-organization of health services considers interdisciplinary work as an objective, as it is necessary to care for the patient in an integral manner, with the consequent benefit of a more efficient service. In addition it is known that patients with psychosocial dysfunctions who use general practice care facilities overutilize these services in an unnecessary manner. With this in mind it is clear that is necessary to balance the service's cost-benefit for a more efficient clinical attention. In this paper we present the results of the categories mentioned above: life events, coping responses and its relationship with emotional state in a representative sample of 399 female patients who in 1986 received services at the National Institute of Perinatology-INPer-. Of these patients, 297 were obstetrical patients -OBS- and 102 gynaecological ones -GINE-. All patients answered these instruments: General Health Questionnaire -GHQ-7 of 30 items, a subscale of Health and Daily Living for Coping Responses and Life Events Scale.(ABSTRACT TRUNCATED AT 250 WORDS)

  7. DIRECT IMAGING AND SPECTROSCOPY OF A YOUNG EXTRASOLAR KUIPER BELT IN THE NEAREST OB ASSOCIATION

    International Nuclear Information System (INIS)

    Currie, Thayne; Lisse, Carey M.; Kuchner, Marc; Madhusudhan, Nikku; Kenyon, Scott J.; Thalmann, Christian; Carson, Joseph; Debes, John

    2015-01-01

    We describe the discovery of a bright, young Kuiper belt–like debris disk around HD 115600, a ∼1.4–1.5 M ⊙ , ∼15 Myr old member of the Sco–Cen OB Association. Our H-band coronagraphy/integral field spectroscopy from the Gemini Planet Imager shows the ring has a (luminosity-scaled) semimajor axis of (∼22 AU) ∼ 48 AU, similar to the current Kuiper belt. The disk appears to have neutral-scattering dust, is eccentric (e ∼ 0.1–0.2), and could be sculpted by analogs to the outer solar system planets. Spectroscopy of the disk ansae reveal a slightly blue to gray disk color, consistent with major Kuiper belt chemical constituents, where water ice is a very plausible dominant constituent. Besides being the first object discovered with the next generation of extreme adaptive optics systems (i.e., SCExAO, GPI, SPHERE), HD 115600's debris ring and planetary system provide a key reference point for the early evolution of the solar system, the structure, and composition of the Kuiper belt and the interaction between debris disks and planets

  8. DIRECT IMAGING AND SPECTROSCOPY OF A YOUNG EXTRASOLAR KUIPER BELT IN THE NEAREST OB ASSOCIATION

    Energy Technology Data Exchange (ETDEWEB)

    Currie, Thayne [National Astronomical Observatory of Japan, Subaru Telescope, Hilo, HI (United States); Lisse, Carey M. [Applied Physics Laboratory, The Johns Hopkins University, Laurel, MD (United States); Kuchner, Marc [NASA Goddard Space Flight Center, Greenbelt, MD (United States); Madhusudhan, Nikku [Institute for Astronomy, University of Cambridge, Cambridge (United Kingdom); Kenyon, Scott J. [Harvard-Smithsonian Center for Astrophysics, Cambridge, MA (United States); Thalmann, Christian [ETH-Zurich, Zurich (Switzerland); Carson, Joseph [Department of Physics and Astronomy, The College of Charleston, Charleston, SC (United States); Debes, John [Space Telescope Science Institute, Baltimore, MD (United States)

    2015-07-01

    We describe the discovery of a bright, young Kuiper belt–like debris disk around HD 115600, a ∼1.4–1.5 M{sub ⊙}, ∼15 Myr old member of the Sco–Cen OB Association. Our H-band coronagraphy/integral field spectroscopy from the Gemini Planet Imager shows the ring has a (luminosity-scaled) semimajor axis of (∼22 AU) ∼ 48 AU, similar to the current Kuiper belt. The disk appears to have neutral-scattering dust, is eccentric (e ∼ 0.1–0.2), and could be sculpted by analogs to the outer solar system planets. Spectroscopy of the disk ansae reveal a slightly blue to gray disk color, consistent with major Kuiper belt chemical constituents, where water ice is a very plausible dominant constituent. Besides being the first object discovered with the next generation of extreme adaptive optics systems (i.e., SCExAO, GPI, SPHERE), HD 115600's debris ring and planetary system provide a key reference point for the early evolution of the solar system, the structure, and composition of the Kuiper belt and the interaction between debris disks and planets.

  9. A CATALOG OF NEW SPECTROSCOPICALLY CONFIRMED MASSIVE OB STARS IN CARINA

    Energy Technology Data Exchange (ETDEWEB)

    Alexander, Michael J.; Hanes, Richard J.; McSwain, M. Virginia [Department of Physics, Lehigh University, 16 Memorial Drive East, Bethlehem, PA 18015 (United States); Povich, Matthew S., E-mail: alexamic@lafayette.edu, E-mail: rjh314@lehigh.edu, E-mail: mcswain@lehigh.edu, E-mail: mspovich@cpp.edu [Department of Physics and Astronomy, California State Polytechnic University, Pomona, CA 91768 (United States)

    2016-12-01

    The Carina star-forming region is one of the largest in the Galaxy, and its massive star population is still being unveiled. The large number of stars combined with high, and highly variable, interstellar extinction makes it inherently difficult to find OB stars in this type of young region. We present the results of a spectroscopic campaign to study the massive star population of the Carina Nebula, with the primary goal to confirm or reject previously identified Carina OB star candidates. A total of 141 known O- and B-type stars and 94 candidates were observed, of which 73 candidates had high enough signal-to-noise ratio to classify. We find 23 new OB stars within the Carina Nebula, a 32% confirmation rate. One of the new OB stars has blended spectra and is suspected to be a double-lined spectroscopic binary (SB2). We also reclassify the spectral types of the known OB stars and discover nine new SB2s among this population. Finally, we discuss the spatial distribution of these new OB stars relative to known structures in the Carina Nebula.

  10. THE NON-THERMAL, TIME-VARIABLE RADIO EMISSION FROM Cyg OB2 no. 5: A WIND-COLLISION REGION

    International Nuclear Information System (INIS)

    Ortiz-Leon, Gisela N.; Loinard, Laurent; RodrIguez, Luis F.; Dzib, Sergio A.; Mioduszewski, Amy J.

    2011-01-01

    The radio emission from the well-studied massive stellar system Cyg OB2 no. 5 is known to fluctuate with a period of 6.7 years between a low-flux state, when the emission is entirely of free-free origin, and a high-flux state, when an additional non-thermal component (of hitherto unknown nature) appears. In this paper, we demonstrate that the radio flux of that non-thermal component is steady on timescales of hours and that its morphology is arc-like. This shows that the non-thermal emission results from the collision between the strong wind driven by the known contact binary in the system and that of an unseen companion on a somewhat eccentric orbit with a 6.7 year period and a 5-10 mas semimajor axis. Together with the previously reported wind-collision region located about 0.''8 to the northeast of the contact binary, so far Cyg OB2 no. 5 appears to be the only multiple system known to harbor two radio-imaged wind-collision regions.

  11. Utility of abdominal skin plus subcutaneous fat and rectal mucosal biopsy in the diagnosis of AL amyloidosis with renal involvement.

    Directory of Open Access Journals (Sweden)

    Ting Li

    Full Text Available Skin fat biopsy of the abdominal wall is a simple and safe method for detecting amyloidosis, and rectal mucosal biopsy is also frequently used for screening for the disease; however, the sensitivity of these approaches has not been fully studied. The aim of this study was to evaluate the efficacy of skin fat biopsy combined with rectal mucosal biopsy as a screening procedure for the diagnosis of systemic immunoglobulin light-chain (AL amyloidosis.We retrospectively analyzed 224 AL amyloidosis patients confirmed by renal biopsy, including a test group of 165 patients and validation group of 59 patients. Surgical skin fat biopsy from the abdominal wall and rectal mucosal biopsy under endoscopy was performed to obtain specimens. Congo red staining and immunofluorescence staining with antibodies against light chains were performed to type the disease. Pathology reports were reviewed to assess the diagnostic sensitivity of skin fat biopsy and rectal mucosal biopsy. Diagnostic specificity was not examined in the present study, because no healthy volunteers and only few patients with other diseases had performed immunofluorescence staining on skin fat and rectal specimens.Of the 165 patients in the test group, Congo red staining of skin fat and rectal mucosal specimens was associated with a sensitivity of 89.3% and 94.8%, respectively. The sensitivity increased to 98.9% by combining both biopsy methods. Immunofluorescence stains were positive in 81.1% of patients undergoing skin fat biopsy and 84.7% of patients undergoing rectal mucosal biopsy. Immunofluorescence stains yielded positive results in 86.7% of cases combining skin fat biopsy with rectal mucosal biopsy. The diagnostic results also performed well in the validation group.Surgical skin biopsy including the subcutaneous fat pad can be performed safely at the bedside and is useful for diagnosing AL amyloidosis. Combining skin fat biopsy with rectal mucosal biopsy may identify amyloid deposits in

  12. Comparison of sonoelastography guided biopsy with systematic biopsy: impact on prostate cancer detection

    International Nuclear Information System (INIS)

    Pallwein, Leo; Struve, Peter; Aigner, Friedrich; Gradl, Johann; Schurich, Matthias; Frauscher, Ferdinand; Mitterberger, Michael; Horninger, Wolfgang; Bartsch, Georg; Pedross, Florian

    2007-01-01

    A prospective study was performed to determine the value of sonoelastography (SE) targeted biopsy for prostate cancer (PCa) detection. A series of 230 male screening volunteers was examined. Two independent examiners evaluated each subject. One single investigator performed ≤5 SE targeted biopsies into suspicious regions in the peripheral zone only. The stiffness of the lesion was displayed by SE and color-coded from red (soft) to blue (hard). Hard lesions were considered as malignant and targeted by biopsy. Subsequently, another examiner performed ten systematic biopsies. Cancer detection rates of the two techniques were compared. Cancer was detected in 81 of the 230 patients (35%), including 68 (30%) by SE targeted biopsy and in 58 (25%) by systematic biopsy. Cancer was detected by targeted biopsy alone in 23 patients (10%) and by systematic biopsy alone in 13 patients (6%). The detection rate for SE targeted biopsy cores (12.7% or 135 of 1,109 cores) was significantly better than for systematic biopsy cores (5.6% or 130 of 2,300 cores, P < 0.001). SE targeted biopsy in a patient with cancer was 2.9-fold more likely to detect PCa than systematic biopsy. SE targeted biopsy detected more cases of PCa than systematic biopsy, with fewer than half the number of biopsy cores in this prostate-specific antigen screening population. (orig.)

  13. Search for OB stars running away from young star clusters. II. The NGC 6357 star-forming region

    Science.gov (United States)

    Gvaramadze, V. V.; Kniazev, A. Y.; Kroupa, P.; Oh, S.

    2011-11-01

    Dynamical few-body encounters in the dense cores of young massive star clusters are responsible for the loss of a significant fraction of their massive stellar content. Some of the escaping (runaway) stars move through the ambient medium supersonically and can be revealed via detection of their bow shocks (visible in the infrared, optical or radio). In this paper, which is the second of a series of papers devoted to the search for OB stars running away from young ( ≲ several Myr) Galactic clusters and OB associations, we present the results of the search for bow shocks around the star-forming region NGC 6357. Using the archival data of the Midcourse Space Experiment (MSX) satellite and the Spitzer Space Telescope, and the preliminary data release of the Wide-Field Infrared Survey Explorer (WISE), we discovered seven bow shocks, whose geometry is consistent with the possibility that they are generated by stars expelled from the young (~1-2 Myr) star clusters, Pismis 24 and AH03 J1725-34.4, associated with NGC 6357. Two of the seven bow shocks are driven by the already known OB stars, HD 319881 and [N78] 34. Follow-up spectroscopy of three other bow-shock-producing stars showed that they are massive (O-type) stars as well, while the 2MASS photometry of the remaining two stars suggests that they could be B0 V stars, provided that both are located at the same distance as NGC 6357. Detection of numerous massive stars ejected from the very young clusters is consistent with the theoretical expectation that star clusters can effectively lose massive stars at the very beginning of their dynamical evolution (long before the second mechanism for production of runaway stars, based on a supernova explosion in a massive tight binary system, begins to operate) and lends strong support to the idea that probably all field OB stars have been dynamically ejected from their birth clusters. A by-product of our search for bow shocks around NGC 6357 is the detection of three circular

  14. The 3DBiopsy Prostate Biopsy System: Preclinical Investigation of a Needle, Actuator, and Specimen Collection Device Allowing Sampling of Individualized Prostate Lengths Between 20 and 60 mm.

    Science.gov (United States)

    Stone, Nelson N; Mouraviev, Vladimir; Schechter, David; Lucia, M Scott; Smith, Elizabeth E; Arangua, Paul; Hoenemeyer, John; Rosa, Jim; Bawa, Rajan; Crawford, E David

    2017-09-01

    To increase the likelihood of detecting anterior cancers within the prostate and provide a specimen that spans the length of the gland. Newly designed 17- and 15-gauge (G) biopsy needles, a variable actuator, and an integrated pathology system intended for the longer cores were developed and tested for this purpose. Testing was performed comparing 2 common cannula tip grinds, a Vet-point (sharp tip) and a Menghini-point (atraumatic tip), and were tested against 18-G Bard Monopty in porcine kidney. A variable actuator was developed to fire the needle 20-60 mm and tested in cadaver prostates. The aggregate firings for 3 different shot lengths comparing the Vet- with the Menghini-tip cannulas demonstrated 91% vs 85.2% fill (length of specimen/length of core bed, P = .007). A 15-G trocar needle with the Vet-tip cannula also had the best performance, with an aggregate standard deviation of 6.4% across 3 firing ranges and a minimum to maximum specimen length of 81%-105% of potential fill. Cadaver testing with the Vet-tip needles in the actuator for the transrectal (17-G) and transperineal (15-G) biopsies demonstrated mean fills of 93.3% and 76.5%, respectively. The new transrectal ultrasound needle obtained a 2-fold increase in specimen length over the standard Bard device (P actuator, the physician can obtain specimens that include peripheral and anterior zone tissue in 1 core. Determination of cancer location on the longer specimens could enhance focal therapy planning. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Diagnostic Accuracy of Multiparametric Magnetic Resonance Imaging and Fusion Guided Targeted Biopsy Evaluated by Transperineal Template Saturation Prostate Biopsy for the Detection and Characterization of Prostate Cancer.

    Science.gov (United States)

    Mortezavi, Ashkan; Märzendorfer, Olivia; Donati, Olivio F; Rizzi, Gianluca; Rupp, Niels J; Wettstein, Marian S; Gross, Oliver; Sulser, Tullio; Hermanns, Thomas; Eberli, Daniel

    2018-02-21

    We evaluated the diagnostic accuracy of multiparametric magnetic resonance imaging and multiparametric magnetic resonance imaging/transrectal ultrasound fusion guided targeted biopsy against that of transperineal template saturation prostate biopsy to detect prostate cancer. We retrospectively analyzed the records of 415 men who consecutively presented for prostate biopsy between November 2014 and September 2016 at our tertiary care center. Multiparametric magnetic resonance imaging was performed using a 3 Tesla device without an endorectal coil, followed by transperineal template saturation prostate biopsy with the BiopSee® fusion system. Additional fusion guided targeted biopsy was done in men with a suspicious lesion on multiparametric magnetic resonance imaging, defined as Likert score 3 to 5. Any Gleason pattern 4 was defined as clinically significant prostate cancer. The detection rates of multiparametric magnetic resonance imaging and fusion guided targeted biopsy were compared with the detection rate of transperineal template saturation prostate biopsy using the McNemar test. We obtained a median of 40 (range 30 to 55) and 3 (range 2 to 4) transperineal template saturation prostate biopsy and fusion guided targeted biopsy cores, respectively. Of the 124 patients (29.9%) without a suspicious lesion on multiparametric magnetic resonance imaging 32 (25.8%) were found to have clinically significant prostate cancer on transperineal template saturation prostate biopsy. Of the 291 patients (70.1%) with a Likert score of 3 to 5 clinically significant prostate cancer was detected in 129 (44.3%) by multiparametric magnetic resonance imaging fusion guided targeted biopsy, in 176 (60.5%) by transperineal template saturation prostate biopsy and in 187 (64.3%) by the combined approach. Overall 58 cases (19.9%) of clinically significant prostate cancer would have been missed if fusion guided targeted biopsy had been performed exclusively. The sensitivity of

  16. Technical note: CT-guided biopsy of lung masses using an automated guiding apparatus

    International Nuclear Information System (INIS)

    Chellathurai, Amarnath; Kanhirat, Saneej; Chokkappan, Kabilan; Swaminathan, Thiruchendur S; Kulasekaran, Nadhamuni

    2009-01-01

    Automated guiding apparatuses for CT-guided biopsies are now available. We report our experience with an indigenous system to guide lung biopsies. This system gave results similar to those with the manual technique. Automated planning also appears to be technically easier, it requires fewer number of needle passes, consumes less time, and requires fewer number of check scans

  17. SPITZER IRS SPECTRA OF DEBRIS DISKS IN THE SCORPIUS–CENTAURUS OB ASSOCIATION

    Energy Technology Data Exchange (ETDEWEB)

    Jang-Condell, Hannah [Department of Physics and Astronomy, University of Wyoming, Laramie, WY 82071 (United States); Chen, Christine H.; Mittal, Tushar; Lisse, Carey M. [Space Telescope Science Institute, 3700 San Martin Dr., Baltimore, MD 21218 (United States); Manoj, P. [Department of Astronomy and Astrophysics, Tata Institute of Fundamental Research, Homi Bhabha Rd., Mumbai 400005 (India); Watson, Dan [Department of Physics and Astronomy, University of Rochester, Rochester, NY 14627 (United States); Nesvold, Erika; Kuchner, Marc [NASA Goddard Space Flight Center, Greenbelt, MD (United States)

    2015-08-01

    We analyze spectra obtained with the Spitzer Infrared Spectrograph (IRS) of 110 B-, A-, F-, and G-type stars with optically thin infrared excess in the Scorpius–Centaurus OB association. The ages of these stars range from 11 to 17 Myr. We fit the infrared excesses observed in these sources by Spitzer IRS and the Multiband Imaging Photometer for Spitzer (MIPS) to simple dust models according to Mie theory. We find that nearly all of the objects in our study can be fit by one or two belts of dust. Dust around lower mass stars appears to be closer in than around higher mass stars, particularly for the warm dust component in the two-belt systems, suggesting a mass-dependent evolution of debris disks around young stars. For those objects with stellar companions, all dust distances are consistent with truncation of the debris disk by the binary companion. The gaps between several of the two-belt systems can place limits on the planets that might lie between the belts, potentially constraining the mass and locations of planets that may be forming around these stars.

  18. Nanoparticle Delivered Human Biliverdin Reductase-Based Peptide Increases Glucose Uptake by Activating IRK/Akt/GSK3 Axis: The Peptide Is Effective in the Cell and Wild-Type and Diabetic Ob/Ob Mice

    Directory of Open Access Journals (Sweden)

    Peter E. M. Gibbs

    2016-01-01

    Full Text Available Insulin’s stimulation of glucose uptake by binding to the IRK extracellular domain is compromised in diabetes. We have recently described an unprecedented approach to stimulating glucose uptake. KYCCSRK (P2 peptide, corresponding to the C-terminal segment of hBVR, was effective in binding to and inducing conformational change in the IRK intracellular kinase domain. Although myristoylated P2, made of L-amino acids, was effective in cell culture, its use for animal studies was unsuitable. We developed a peptidase-resistant formulation of the peptide that was efficient in both mice and cell culture systems. The peptide was constructed of D-amino acids, in reverse order, and blocked at both termini. Delivery of the encapsulated peptide to HepG2 and HSKM cells was confirmed by its prolonged effect on stimulation of glucose uptake (>6 h. The peptide improved glucose clearance in both wild-type and Ob/Ob mice; it lowered blood glucose levels and suppressed glucose-stimulated insulin secretion. IRK activity was stimulated in the liver of treated mice and in cultured cells. The peptide potentiated function of IRK’s downstream effector, Akt-GSK3-(α,β axis. Thus, P2-based approach can be used for improving glucose uptake by cells. Also, it allows for screening peptides in vitro and in animal models for treatment of diabetes.

  19. Towards the mid-infrared optical biopsy

    DEFF Research Database (Denmark)

    Seddon, Angela B.; Benson, Trevor M.; Sujecki, Slawomir

    2016-01-01

    We are establishing a new paradigm in mid-infrared molecular sensing, mapping and imaging to open up the mid-infrared spectral region for in vivo (i.e. in person) medical diagnostics and surgery. Thus, we are working towards the mid-infrared optical biopsy ('opsy' look at, bio the biology) in situ...... in the body for real-time diagnosis. This new paradigm will be enabled through focused development of devices and systems which are robust, functionally designed, safe, compact and cost effective and are based on active and passive mid-infrared optical fibers. In particular, this will enable early diagnosis...... of a bright mid-infrared wideband source in a portable package as a first step for medical fiber-based systems operating in the mid-infrared. Moreover, mid-infrared molecular mapping and imaging is potentially a disruptive technology to give improved monitoring of the environment, energy efficiency, security...

  20. Fluoroscopy-guided transnasal biopsy of nasopharyngeal carcinoma using a flexible bronchoscopic biopsy forcep

    International Nuclear Information System (INIS)

    Kim, Jai Keun; Chung, Tae Sub; Kim, Dong Ik; Suh, Jung Ho

    1996-01-01

    Otolaryngoscopic biopsy of nasopharyngeal carcinoma is a generalized method which may be associated with inadequate sampling of tissue and patient discomfort. So, we tried fluoroscopy-guided transnasal biopsy using bronchoscopic biopsy forcep and evaluated its safety and efficacy. Prospectively we performed fluoroscopy-guided transnasal biopsy in 11 patients who were radiographically suspected of nasopharyngeal carcinoma. The posterior wall of the nasopharynx was coated with barium sulfate under fluoroscopy. A flexible bronchoscopic biopsy forcep with a steerable guiding catheter which was used in removal of intrahepatic duct stones was inserted through the nare. After localization of the tip of the biopsy forcep at tumor site with fluoroscopy, a tissue specimen was obtained. We also tried CT guided biopsy in initial 2cases. Each patient had otolaryngoscopic biopsy to compare the biopsy result and patient discomfort. We could have sufficient amount of tissue for pathological evaluation in 10 of 11 patients by the first pass with the fluoroscopic technique. Contrarily, otolaryngoscopic biopsy was successful in 7 of 11 patients on single passage. Additionally, 2 patients had complaint in our method comparing with 9 patients in otolaryngoscopic biopsy. Fluoroscopy-guided transnasal biopsy of nasopharyngeal carcinoma using the bronchoscopic biopsy forcep is safe and accurate. It can be a appropriate method competing otolaryngoscopic biopsy

  1. Plutonium speciation and isotope ratios in Yenisey and Ob river and Yenisey estuary

    International Nuclear Information System (INIS)

    Skipperud, L.; Oughton, DH.; Fifield, K.; Lind, O.C.; Salbu, B.; Brown, J.

    2004-01-01

    Plutonium isotope ratios are known to vary with reactor type, nuclear fuel-burn up time, neutron flux, and energy, and for fallout from nuclear detonations, weapon type and yield. Weapons-grade plutonium is characterized by a low content of the 240 Pu isotope, with 240 Pu/ 239 Pu isotope ratio less than 0.05. In contrast, both global weapons fallout and spent nuclear fuel from civil reactors have higher 240 Pu/ 239 Pu isotope ratios (civil nuclear power reactors have 240 Pu/ 239 Pu atom ratios of between about 0.2-1). Thus, different sources often exhibit characteristic plutonium isotope ratios and these ratios can be used to identify the origin of contamination, calculate inventories, or follow the migration of contaminated sediments and waters. Together with activity measurements and isotope ratios, knowledge of plutonium speciation in the Ob and Yenisey rivers and processes controlling its behaviour in estuarine systems is a prerequisite for predicting the transfer and subsequent environmental impact to Arctic Seas. With this in mind, the study had two objectives: first to determine whether discharges from nuclear installations in the river catchment areas are having any influence on Pu levels in the estuaries; and, second, to investigate the transfer and mobility of plutonium in the Yenisey river and estuary. Plutonium 240/239 ratios were determined using accelerator mass spectrometry (AMS). The data indicated a clear influence from a low 240 Pu: 239 Pu source in surface sediments collected from the Yenisey Estuary, whereas plutonium in the Ob Estuary sediments are dominated by global fallout. The results also show an increase in plutonium concentration and a decrease in isotope ratio going upstream from the estuary. Sequential extractions of sediments indicate that up 70% of the Pu in the Yenisey river is easily mobilized with weak oxidizing agents, which indicates that the Pu is organically bound, while the Pu is more strongly irreversible bound further out

  2. MR-guided biopsies of lesions in the retroperitoneal space: technique and results

    International Nuclear Information System (INIS)

    Zangos, S.; Eichler, K.; Wetter, A.; Lehnert, T.; Hammerstingl, R.; Diebold, T.; Reichel, P.; Herzog, C.; Mack, M.G.; Vogl, T.J.; Hansmann, M.-L.

    2006-01-01

    The purpose of this study was to evaluate the safety and precision of MRI-guided biopsies of retroperitoneal space-occupying tumors in an open low-field system. In 30 patients with indistinct retroperitoneal tumors [paraaortic lesion (n=20), kidney (n=2), suprarenal gland (n=3) and pancreas (n=5)] MR-guided biopsies were performed using a low-field system (0.2 T, Magnetom Concerto, Siemens, Germany). For the monitoring of the biopsies T1-weighted FLASH sequences (TR/TE=160/5 ms; 90 ) were used in all patients and modified FLASH sequences (TR/TE=160/13 ms; 90 ) in ten patients. After positioning of the needle in the tumors 114 biopsy specimens were acquired in coaxial technique with 16-gauge cutting needles (Somatex, Germany). The biopsies were successfully performed in all patients without vascular or organ injuries. The visualization of the aortic blood flow with MRI facilitated the biopsy procedures of paraaortic lesions. The size of the lesions ranged from 1.6 to 7.5 cm. The median distance of the biopsy access path was 10.4 cm. Adequate specimens were obtained in 28 cases (93.3%) resulting in a correct histological classification of 27 lesions (90%). In conclusion, MR-guided biopsies of retroperitoneal lesions using an open low-field system can be performed safely and accurately and is an alternative to CT-guided biopsies. (orig.)

  3. Computed tomography-guided percutaneous biopsy of pancreatic masses using pneumodissection

    Directory of Open Access Journals (Sweden)

    Chiang Jeng Tyng

    2013-06-01

    Full Text Available Objective To describe the technique of computed tomography-guided percutaneous biopsy of pancreatic tumors with pneumodissection. Materials and Methods In the period from June 2011 to May 2012, seven computed tomography-guided percutaneous biopsies of pancreatic tumors utilizing pneumodissection were performed in the authors' institution. All the procedures were performed with an automatic biopsy gun and coaxial system with Tru-core needles. The biopsy specimens were histologically assessed. Results In all the cases the pancreatic mass could not be directly approached by computed tomography without passing through major organs and structures. The injection of air allowed the displacement of adjacent structures and creation of a safe coaxial needle pathway toward the lesion. Biopsy was successfully performed in all the cases, yielding appropriate specimens for pathological analysis. Conclusion Pneumodissection is a safe, inexpensive and technically easy approach to perform percutaneous biopsy in selected cases where direct access to the pancreatic tumor is not feasible.

  4. Computed tomography-guided percutaneous biopsy of pancreatic masses using pneumodissection

    International Nuclear Information System (INIS)

    Tyng, Chiang Jeng; Bitencourt, Almir Galvao Vieira; Almeida, Maria Fernanda Arruda; Barbosa, Paula Nicole Vieira; Martins, Eduardo Bruno Lobato; Junior, Joao Paulo Kawaoka Matushita; Chojniak, Rubens; Coimbra, Felipe Jose Fernandez

    2013-01-01

    Objective: to describe the technique of computed tomography-guided percutaneous biopsy of pancreatic tumors with pneumodissection. Materials and methods: in the period from June 2011 to May 2012, seven computed tomography guided percutaneous biopsies of pancreatic tumors utilizing pneumodissection were performed in the authors' institution. All the procedures were performed with an automatic biopsy gun and coaxial system with Tru-core needles. The biopsy specimens were histologically assessed. Results: in all the cases the pancreatic mass could not be directly approached by computed tomography without passing through major organs and structures. The injection of air allowed the displacement of adjacent structures and creation of a safe coaxial needle pathway toward the lesion. Biopsy was successfully performed in all the cases, yielding appropriate specimens for pathological analysis. Conclusion: Pneumodissection is a safe, inexpensive and technically easy approach to perform percutaneous biopsy in selected cases where direct access to the pancreatic tumor is not feasible. (author)

  5. 'Microerosions' in rectal biopsies in Crohn's disease

    DEFF Research Database (Denmark)

    Poulsen, Steen Seier

    1984-01-01

    Small (less than 1 mm), superficial erosions ('microerosions') have been observed stereo-microscopically in surface-stained rectal biopsies in Crohn's disease (CD). Biopsy specimens from 97 patients with CD, 225 with ulcerative colitis (UC), and a control material of 161 patients were investigated....... Granulomas were identified in 62% of the biopsies with microerosions and by examination of two consecutive biopsies from each of these patients, in 85% indicating a positive correlation. In patients with microerosions and a primary diagnosis of UC, granulomas were found in 38% and by examination of two...... biopsies in 54%. Patients with granulomas and a few other patients were reclassified as CD, but there still remained some patients with microerosions, who most probably had UC. In conclusion, microerosions are observed mainly in CD with colonic involvement. There is a high incidence of granulomas in biopsy...

  6. Are breast biopsies adequately funded? A process cost and revenue analysis; Ist die Mammabiopsie ausreichend finanziert? Eine Prozesskosten und Erloesbetrachtung

    Energy Technology Data Exchange (ETDEWEB)

    Hahn, M.; Fischbach, E.; Fehm, T. [Universitaetsklinikum Tuebingen (DE). Dept. of Obstetrics and Gynecology] (and others)

    2011-04-15

    Purpose: The objective of the study was to determine whether the various breast biopsy procedures specified in the S 3 guidelines are sensibly represented within the current German health system as considered from a cost evaluation perspective. Materials and Methods: This prospectively designed multicenter study analyzed 221 breast biopsies at 7 institutions from 04/2006 to 01/2007. Core needle biopsies, vacuum-assisted biopsies and surgical open biopsies under sonographic or mammographic guidance were evaluated. During an analysis of process costs, the individual process steps were recorded in diagrammatic form and assigned to the true consumption of resources. The actual resource consumption costs were entered. A process-related breakeven analysis was conducted to check whether the reimbursement of individual biopsy types covers the costs. Results: Only sonographically guided core needle biopsy and surgical open biopsy are adequately reimbursed in the current German health system. All other breast biopsies indicate a negative profit margin. The principal reasons for underfunding are found in the area of reimbursement of investment and non-personnel costs. Conclusion: The reimbursement of breast biopsies must be improved in order to guarantee nationwide care of the population using the breast biopsy methods recommended in the S 3 guidelines and to avoid disincentives with respect to breast biopsy indications. (orig.)

  7. Ultrasound guided needle biopsy of skeletal muscle in neuromuscular disease

    DEFF Research Database (Denmark)

    Lindequist, S; Schrøder, H D; Larsen, C

    1990-01-01

    Guided by ultrasonography percutaneous needle biopsy of skeletal muscle was performed in 24 patients, using the one hand held Biopty system and a 2 mm Tru-Cut needle. The specimens were graded with regard to diagnostic quality and utility and almost all specimens (96%) were of highest quality. Th....... The use of ultrasonography was helpful in selecting a suitable area for the biopsy and vascular structures could be avoided. The procedure was well tolerated and easy to perform, and no complications were recorded....

  8. Renal biopsies in Johor: a 7-year study.

    Science.gov (United States)

    Khoo, J J

    2001-12-01

    Consecutive renal biopsies received from 1994 to 2000 in Johor Bahru were reviewed. There were 441 cases, of which 407 were adequate biopsies (92.3%). Lupus nephritis formed the largest diagnostic entity (126 cases, 31.0%). This reflected the high prevalence of systemic lupus erythematosus (SLE) patients in Malaysia. The most common histological pattern of lupus nephritis was diffuse proliferative glomerulonephritis: WHO Class IV (96 cases, 76.2%). Other diagnostic entities were minimal change disease (28.5%), proliferative glomerulonephritis (10.6%), IgA nephropathy (9.8%), focal glomerulosclerosis (4.9%), membranous glomerulonephritis (4.4%), transplant rejection (3.9%), end stage nephropathy (3.4%) and others (3.4%). The morphological pattern of renal biopsies in Johor was similar to that reported in the University Hospital Kuala Lumpur.

  9. Nerve Biopsy In The Diagnosis Of Leporsy

    OpenAIRE

    Hazra B; Banerjee P P; Bhattacharyya N K; Gupta P N; Barbhunia J N; Sanyal S

    1997-01-01

    Skin and nerve biopsies were done in 33 cases of different clinical types of leprosy selected from Dermatology OPD of Medical College and Hospitals, Calcutta during 1994-95. Histopathological results were compared with emphasis on the role of nerve biopsies in detection of patients with multibacillary leprosy. The evident possibility of having patients with multibacillary leprosy in peripheral leprosy with multiple drugs. It is found that skin and nerve biopsy are equally informative in borde...

  10. Infective endocarditis with spondylodiscitis after prostate biopsy

    Directory of Open Access Journals (Sweden)

    Fernando Pivatto Júnior

    2014-04-01

    Full Text Available Transrectal ultrasonography-guided prostate needle biopsy is the ideal method to obtain prostate specimens for histological analysis and is therefore frequently used in clinical practice. In the majority of the studies, prostate biopsy is considered a safe procedure with few major complications. In the present report, we describe a case of endocarditis with spondylodiscitis, two very rare complications of prostate biopsy.

  11. Biopsy-proven childhood glomerulonephritis in Johor.

    Science.gov (United States)

    Khoo, J J; Pee, S; Thevarajah, B; Yap, Y C; Chin, C K

    2004-06-01

    There has been no published study of biopsy-proven childhood glomerulonephritis in Malaysia. To determine the pattern of childhood glomerulonephritis in Johor, Malaysia from a histopathological perspective and the various indications used for renal biopsy in children. Retrospective study was done of all renal biopsies from children under 16 years of age, received in Sultanah Aminah Hospital, Johor between 1994 and 2001. The histopathological findings were reviewed to determine the pattern of biopsy-proven glomerulonephritis. The indications for biopsy, mode of therapy given after biopsy and the clinical outcome were studied. 122 adequate biopsies were received, 9 children had repeat biopsies. Of the 113 biopsies, minimal change disease formed the most common histopathological diagnosis (40.7%) while lupus nephritis formed the most common secondary glomerulonephritis (23.0%). The main indications for biopsy were nephrotic syndrome (50.8%), lupus nephritis (25.4%) and renal impairment (13.1%). The mode of therapy was changed in 59.8% of the children. Of 106 patients followed-up, 84 children were found to have normal renal function in remission or on treatment. 4 patients developed chronic renal impairment and 16 reached end stage renal disease. Five of the 16 children with end stage disease had since died while 11 were on renal replacement therapy. Another 2 patients died of other complications. The pattern of childhood GN in our study tended to reflect the more severe renal parenchymal diseases in children and those requiring more aggressive treatment. This was because of our criteria of selection (indication) for renal biopsy. Renal biopsy where performed appropriately in selected children may not only be a useful investigative tool for histological diagnosis and prognosis but may help clinicians plan the optimal therapy for these children.

  12. New Version of SeismicHandler (SHX) based on ObsPy

    Science.gov (United States)

    Stammler, Klaus; Walther, Marcus

    2016-04-01

    The command line version of SeismicHandler (SH), a scientific analysis tool for seismic waveform data developed around 1990, has been redesigned in the recent years, based on a project funded by the Deutsche Forschungsgemeinschaft (DFG). The aim was to address new data access techniques, simplified metadata handling and a modularized software design. As a result the program was rewritten in Python in its main parts, taking advantage of simplicity of this script language and its variety of well developed software libraries, including ObsPy. SHX provides an easy access to waveforms and metadata via arclink and FDSN webservice protocols, also access to event catalogs is implemented. With single commands whole networks or stations within a certain area may be read in, the metadata are retrieved from the servers and stored in a local database. For data processing the large set of SH commands is available, as well as the SH scripting language. Via this SH language scripts or additional Python modules the command set of SHX is easily extendable. The program is open source, tested on Linux operating systems, documentation and download is found at URL "https://www.seismic-handler.org/".

  13. Hypoxia marker labeling in tumor biopsies: quantification of labeling variation and criteria for biopsy sectioning

    International Nuclear Information System (INIS)

    Thrall, Donald E.; Rosner, Gary L.; Azuma, Chieko; McEntee, Margaret C.; Raleigh, James A.

    1997-01-01

    Background and purpose: The error associated with using biopsy-based methods for assessing parameters reflective of the tumor microenvironment depends on the variability in distribution of the parameter throughout the tumor and the biopsy sample. Some attention has been given to intratumoral distribution of parameters, but little attention has been given to their intrabiopsy distribution. We evaluated the intrabiopsy distribution of CCI-103F, a 2-nitroimidazole hypoxia marker. Materials and methods: The hypoxia marker CCI-103F was studied in dogs bearing spontaneous solid tumors. Two biopsies were taken from each of seven tumors, for a total of 14 biopsies. Biopsies were serially sectioned and four to six contiguous slides from each 100-150 μm of the biopsy were used to formulate the best estimate of CCI-103F labeled area throughout the biopsy sample. One, two or four slides were then randomly selected from each biopsy and the labeled area, based on this limited sample, was compared to the estimate obtained from counting all available slides. Random sampling of slides was repeated 1000 times for each biopsy sample. Results: CCI-103F labeling variance throughout the biopsy decreased as the estimated overall labeled area in the biopsy decreased. The error associated with estimating the overall labeled area in a biopsy from a randomly selected subset of slides decreased as the number of slides increased, and as the overall labeled area in the biopsy decreased. No minimally labeled biopsy was classified as unlabeled based on limited sampling. Conclusion: With regard to CCI-103F labeling, quantification of the labeled area in four randomly selected slides from a biopsy can provide, in most biopsies, an estimate of the labeled area in the biopsy within an absolute range of ±0.05

  14. When size matters: diagnostic value of kidney biopsy according to the gauge of the biopsy needle.

    Science.gov (United States)

    Roth, Rachel; Parikh, Samir; Makey, Dayanand; Foster, Jamison; Rozenblit, Grigory; Satoskar, Anjali; Nadasdy, Gyongyi; Von Visger, Jon; Hebert, Lee; Rovin, Brad H; Nadasdy, Tibor; Brodsky, Sergey V

    2013-01-01

    Kidney biopsy is a vital tool in the diagnosis of kidney disease. Although it has become a routine procedure, it is not complication-free. Some serious complications of percutaneous kidney biopsy include retroperitoneal hemorrhage and death. There is an increased belief that smaller biopsy needle size results in a lower complication rate. As renal pathologists, we witness an increased number of kidney biopsies performed with a small needle size (as low as gauge 22), which results in inadequate tissue sampling and often non-diagnostic biopsy results. Herein we report the diagnostic value of kidney biopsies according to the size of the biopsy needles. We performed kidney biopsies from nephrectomy specimens using biopsy needles of different sizes. Morphologic parameters were analyzed. We found that biopsies performed by small needles (gauges 20 and 22) contain significantly lower numbers of glomeruli and blood vessels, which limits pathologic evaluation. Data from our institution do not show differences in kidney biopsy complication rates between 16- and 18-gauge needles. Our data indicate that small biopsy needles do not provide sufficient material for diagnosis, and they increase the likelihood for a repeat biopsy. Copyright © 2013 S. Karger AG, Basel.

  15. Nerve Biopsy In The Diagnosis Of Leporsy

    Directory of Open Access Journals (Sweden)

    Hazra B

    1997-01-01

    Full Text Available Skin and nerve biopsies were done in 33 cases of different clinical types of leprosy selected from Dermatology OPD of Medical College and Hospitals, Calcutta during 1994-95. Histopathological results were compared with emphasis on the role of nerve biopsies in detection of patients with multibacillary leprosy. The evident possibility of having patients with multibacillary leprosy in peripheral leprosy with multiple drugs. It is found that skin and nerve biopsy are equally informative in borderline and lepromatour leprosy and is the only means to diagnose polyneuritic leprosy. Nerve biopsy appears to be more informative in the diagnosis of all clinical types of leprosy.

  16. Surface staining of small intestinal biopsies

    DEFF Research Database (Denmark)

    Poulsen, Steen Seier

    1977-01-01

    Small intestinal biopsies are most often by routine examined under a stereo-microscope, prior to embedding for histological examination. This is done in order to get a view of the appearance of the mucosal pattern, especially villus configuration. The distinctness of the surface pattern however......, is improved considerably if the biopsies are stained with Alcian Green and/or PAS before they are examined. In the present paper a detailed description is given of staining of small intestinal biopsies as whole mounts. The difference between the unstained and the stained biopsies is illustrated by a few...

  17. Robotic Prostate Biopsy in Closed MRI Scanner

    National Research Council Canada - National Science Library

    Fischer, Gregory

    2008-01-01

    .... This work enables prostate brachytherapy and biopsy procedures in standard high-field diagnostic MRI scanners through the development of a robotic needle placement device specifically designed...

  18. Punch Biopsy Results in Misdiagnosis of Pilomatrixoma

    Directory of Open Access Journals (Sweden)

    Metin Temel

    2017-03-01

    Full Text Available Punch biopsy results in misdiagnosis of clinically unsuspected giant pilomatrixoma located over the parotid gland. This study presents a case of pilomatrixoma that was misdiagnosed as a malignant epithelial tumor using punch biopsy. A 25-year-old male was admitted to our clinic for the evaluation of a mass measuring 7×8×8 cm located over the parotid gland. The patient had previously undergone punch biopsy at another clinic because of a lesion in the parotid gland. Punch biopsy revealed a malignant epithelial tumor. The patient underwent excisional biopsy at our clinic. After the biopsy, the residual skin defect was treated using full-thickness skin grafts. The facial nerve and parotid gland were preserved during the biopsy. Histopathological examination of the excisional biopsy material revealed pilomatrixoma. Punch biopsy may result in misdiagnosis of skin lesions in the parotid gland. A differential diagnosis for benign tumors such as pilomatrixoma is essential prior to an aggressive surgical intervention of the parotid gland.

  19. Adult dementia: history, biopsy, pathology.

    Science.gov (United States)

    Torack, R M

    1979-05-01

    The historical events in the evolution of Alzheimer's disease are reviewed, including the initial description by Alois Alzheimer and the subsequent controversy regarding the nosological specificity of this entity. The similarity of senile dementia and Alzheimer's disease is emphasized. The basis for the modern concept of Alzheimer's disease as premature or accelerated aging is included in the review. The pathological correlates of the major categories of adult dementia have been described. The traditional criteria of neurofibrillary tangles and senile plaques have been re-evaluated using the current insight into these changes afforded by electron microscopy and biochemistry. The significance of amyloid has been described because it occurs within the senile plaque and also as the essential component of congophilic angiopathy. The new information regarding neuronal cell counts and the loss of choline acetyltransferase has been evaluated in terms of an indication of a pathogenic mechanism of Alzheimer's disease. The current understanding of normal pressure hydrocephalus, Creutzfeldt-Jakob disease, and multi-infarct dementia has been described. Brain biopsy in dementia has been described as having diagnostic, research, pathogenic, and prognostic value. The precautions involving the performance and handling of the biopsy have been stressed, particularly because these procedures involve conditions of possible slow virus etiology. The polemic for Alzheimer's disease as aging or slow virus infection has been summarized. At this time a consideration seems justified that Alzheimer's disease is an age-related, slow virus disease due to a hitherto unknown immune defect. Aging as an etiological agent must be clarified before Alzheimer's disease, in any form, can be considered to be an inevitable consequence of longevity.

  20. Percutaneous biopsy of non-palpable breast lesions with the advanced breast biopsy instrumentation (ABBI): analysis of indication strategies

    International Nuclear Information System (INIS)

    Wedegaertner, U.; Otto, U.; Buitrago-Tellez, C.; Bremerich, J.; Bongartz, G.; Oertli, D.; Torhorst, J.

    2001-01-01

    Purpose: To compare the indications for biopsy with and without the use of the Breast Imaging Reporting and Data System. Material and methods: Biopsies using the ABBI were performed in 62 patients with 64 non-palpable evident mammographic lesions. The initial decision for biopsy was made by non-radiologists due to suspicious microcalcifications (n=53) and masses (n=11). The indication was retrospectively reassessed by adopting the BI-RADS classification by three radiologists in consensus. The positive predictive value (PPV) of both indication strategies was assessed and compared. Results: Biopsies adopting ABBI were performed without major side-effects and were diagnostic. Carcinoma was present in 14 lesions: nine specimens were diagnosed as DCIS and five as invasive carcinomas. For the 50 benign lesions histology revealed mastopathies (26/50) and fibroadenomas (8/50) as the most frequent diagnosis. The positive predictive value (PPV) for the initial indication was 22%, whereas PPV for BI-RADS based indications (categories 4 and 5) was 31%. Conclusion: ABBI enables stereotactically-guided procedures that result in representative and diagnostic biopsies. Standardized criteria like BI-RADS improve the PPV and should be a mandatory part of mammographic evaluation. Radiologists should remain involved in the decision making. (orig.) [de

  1. Transjugular Renal Biopsy: Our Experience and Technical Considerations

    International Nuclear Information System (INIS)

    See, Teik Choon; Thompson, Barbara C.; Howie, Alexander J.; Karamshi, M.; Papadopoulou, Anthie M.; Davies, Neil; Tibballs, Jonathan

    2008-01-01

    The purpose of this study was to describe the indications for and technique of transjugular renal biopsy (TJRB) and evaluate the efficacy and complications of this method. We performed a retrospective review of 59 patients who underwent TJRB using the Quick-core needle biopsy system (Cook, Letchworth, UK) over a 4-year period. The indications for obtaining renal biopsy included acute renal failure, chronic renal failure, nephrotic syndrome, and proteinuria with or without other associated disease. Indications for the transjugular approach included coagulopathy, biopsy of a solitary kidney or essentially single functioning kidney, simultaneous renal and hepatic biopsy, morbid obesity, and failed percutaneous biopsy. All but four cases were performed via the right internal jugular vein. The right, left, or both renal veins were cannulated in 41, 14, and 4 cases, respectively. Combined liver and renal biopsies were obtained in seven cases. Diagnostic biopsy specimens were obtained in 56 of 59 patients (95%). The number and size of tissue cores ranged from 1 to 9 mm and from 1 to 20 mm, respectively. The mean numbers of glomeruli per procedure on light microscopy and electron microscopy were 10.3 and 2.6, respectively. Specimens for immunohistology were acquired in 49 cases, of which 40 were adequate. Of the 56 successful TJRB procedures, 34 (61%) were associated with isolated capsular perforation (19), contained subcapsular leak (10), isolated collecting system puncture (1), and concurrent collecting system and capsular perforation (4). There was a significant increase in capsular perforation with six or more needle passes, although no significant correlation was seen between number of needle passes and complication. Six patients had minor complications defined as hematuria or loin pain. Seven patients developed major complications, of whom five received blood transfusion alone. Two required intervention: in one an arteriocalyceal fistula was embolized and the patient

  2. Brain biopsy for diagnosis of chlamydia encephalitis

    Directory of Open Access Journals (Sweden)

    I. A. Voznyuk

    2017-01-01

    Full Text Available This is the case of encephalitis associated with chlamydia infection of central nervous system. The diagnostic protocol of the patient included: a careful observation of somatic and neurological status, laboratory tests of blood and cerebrospinal fluid, neurovisualization. The results of the diagnostic protocol suggest that laboratory tests blood and cerebrospinal fluid possess low sensitivity and specificity. The MRI study has revealed the localization and inflammatory character of the changes in brain tissue; it has also helped to choose the most favorable area for the stereotaxic biopsy. The obtained tissue was evaluated by means of light (immunohistochemistry and electronic microscopy. The active chlamydia infection was estimated. The subsequent antibacterial etiotropic therapy resulted in the regression of the neurologic symptoms and remission.The intravitalpathomorphology study of the brain could be recommended for the management of the severe encephalitis of the unknown origin. 

  3. Production of metal and metal-ceramic coatings on D-Gun Ob

    International Nuclear Information System (INIS)

    Gavrilenko, T.P.; Nikolaev, Y.A.; Ulianitsky, V.Y.

    1995-01-01

    Optimization of the detonation spraying process has been made for the production of metal and metal-ceramics coatings with the D-Gun Ob. Owing to the ability of Ob to work with several fuels and an inert diluent simultaneously, variation of detonation regimes in a wide range is possible, and because of localized powder injection in the D-Gun barrel, high uniformity of parameters of powder particles is achieved. The best conditions for particle heating and acceleration were calculated with the help of mathematical simulation, and the corresponding regimes were realized on D-Gun Ob. High-quality aluminum, copper, nickel, and nickel-chromium-silicon-carbon-boron alloy coatings were produced by using only propane fuel. Chromium carbide with nickel and tungsten carbide with cobalt coatings were produced with addition of acetylene. Optimal efficiency and high bonding strength were achieved for all powders. Data on microhardness, bonding strength, and efficiency are presented

  4. The performance study of oxide by-passed(OB) lateral double diffused MOSFET

    Science.gov (United States)

    Tang, Pan-pan

    2016-10-01

    An SOI LDMOS device structure with Oxide By-passed(OB) was investigated and its breakdown mechanism and characteristic of structure was analyzed. Its performance was verified by 3D numerical simulation with SILVACO TCAD software. The simulated results show that the electrical field element of the device is modulated by the concept of similar Superjunction(SJ) structure. Compared with the SJ LDMOS device, OB LDMOS obtains the same breakdown voltage, simultaneously the specific on-resistance of the OB LDMOS reduces from 3.81mΩ·cm2 to 1.96mΩ·cm2, except for achieving comparable performance and overcoming the high aspect ratio of fabrication structure and the difficulty of accurate concentration match of SJ LDMOS.

  5. The OB run-away stars from Sco-Cen and Orion reviewed

    International Nuclear Information System (INIS)

    Blaauw, A.

    1989-01-01

    The author studies the past paths of the run-away star Zeta Oph from the OB association Sco-Cen, and of the run-away stars AE Aur, Mu Col and 53 Ari from the OB association Ori OB1, in connection with the question of the origin of these high velocities. Should the binary-hypothesis be adhered to (supernova explosion of one of the components) or, perhaps, dynamical evolution in young, dense clusters offer a clue to this phenomenon? It is shown that the latter hypothesis is very unlikely to apply to Zeta Oph. For the run-away stars from Orion conclusive evidence may well be obtained in the course of the next decade, from improved accuracy of the proper motions

  6. Transcriptional activation of the mouse obese (ob) gene by CCAAT/enhancer binding protein alpha

    DEFF Research Database (Denmark)

    Hwang, C S; Mandrup, S; MacDougald, O A

    1996-01-01

    Like other adipocyte genes that are transcriptionally activated by CCAAT/enhancer binding protein alpha (C/EBP alpha) during preadipocyte differentiation, expression of the mouse obese (ob) gene is immediately preceded by the expression of C/EBP alpha. While the 5' flanking region of the mouse ob...... gene contains several consensus C/EBP binding sites, only one of these sites appears to be functional. DNase I cleavage inhibition patterns (footprinting) of the ob gene promoter revealed that recombinant C/EBP alpha, as well as a nuclear factor present in fully differentiated 3T3-L1 adipocytes...... to a consensus C/EBP binding site at nucleotides -55 to -47 generated a specific protein-oligonucleotide complex that was supershifted by antibody against C/EBP alpha. Probes corresponding to two upstream consensus C/EBP binding sites failed to generate protein-oligonucleotide complexes. Cotransfection of a C...

  7. [Muscle biopsy in children: Usefulness in 2012].

    Science.gov (United States)

    Cuisset, J-M; Maurage, C-A; Carpentier, A; Briand, G; Thévenon, A; Rouaix, N; Vallée, L

    2013-01-01

    Muscle biopsy is a mainstay diagnostic tool for investigating neuromuscular disorders in children. We report the yield of pediatric muscle biopsy in a population of 415 children by a retrospective study of 419 biopsies performed between 1/01/2000 and 31/12/2009 in a neuropediatric department, including mitochondrial respiratory chain analysis for 87 children. Two hundred and fifty-five biopsies were from boys (61%) 164 from girls (39%). Their mean age at biopsy was 6.5years; 155 (37%) biopsies were obtained before the child was 5years old. Final histopathological diagnoses were: congenital myopathy (n=193, including 15 structural congenital myopathies); progressive muscular dystrophy (n=75 [18%] including 57 dystrophinopathies); congenital muscular dystrophy (n=17, including six primary merosinopathies); dermatomyositis (n=11); spinal muscular atrophy (n=9, including six atypical spinal muscular atrophies); metabolic myopathy (n=32, including 19 mitochondrial myopathies); encephalomyopathy (n=53 [13%], including 27 with a mitochondrial respiratory chain defect). Pathological diagnosis remained undetermined in 16 cases. In 184 patients (44%), the muscle biopsy revealed specific histopathological anomalies (dystrophic process; specific ultrastructural abnormalities; perifascicular atrophy; neurogenic atrophy; metabolic anomalies) enabling a precise etiological diagnosis. For 85% of progressive muscular dystrophies, the biopsy resulted in a genetic diagnosis after identification of the protein defect. In 15% of the congenital myopathies, histopathological anomalies focused attention on one or several genes. Concerning dystrophinopathies, quantification of dystrophin deficiency on the biopsy specimen contributed to the definition of the clinical phenotype: Duchenne, or Becker. In children with a myopathy, muscle biopsy is often indispensable to establish the etiological diagnosis. Based on the results from this series, muscle biopsy can provide a precise

  8. Outcomes of ultrasound guided renal mass biopsies.

    Science.gov (United States)

    Sutherland, Edward L; Choromanska, Agnieszka; Al-Katib, Sayf; Coffey, Mary

    2018-06-01

    The purpose of this study was to evaluate the rate of nondiagnostic ultrasound-guided renal mass biopsies (RMBs) at our institution and to determine what patient, procedural, and focal renal mass (FRM) factors were associated with nondiagnostic ultrasound-guided RMBs. Eighty-two ultrasound-guided renal mass biopsies performed between January 2014 and October 2016 were included in our study. Biopsy outcomes (diagnostic vs. nondiagnostic) and patient, procedural, and FRM characteristics were retrospectively reviewed and recorded. Univariate statistical analyses were performed to identify biopsy characteristics that were indicative of nondiagnostic biopsy. Ultrasound-guided RMBs were diagnostic in 70 out of 82 cases (85%) and non-diagnostic in 12 cases (15%). Among the diagnostic biopsies, 54 (77%) were malignant cases, 94% of which were renal cell carcinoma (RCC). Of the 12 nondiagnostic cases, the final diagnosis was RCC in 4 cases and angiomyolipoma in one case; seven of the nondiagnostic cases were lost to follow-up. A weak association (p = 0.04) was found between the number of needle passes and the biopsy outcome. None of the remaining collected RMB characteristics showed a significant correlation with a diagnostic or nondiagnostic RMB. Six patients (7%) experienced complications. Ultrasound-guided renal mass biopsy is a safe and effective method for the diagnosis of renal masses with a low rate of nondiagnostic outcomes. A nondiagnostic biopsy should not be treated as a surrogate for a diagnosis since a significant number of patients with nondiagnostic biopsies have subsequently been shown to have renal malignancies. Repeat biopsy should be considered in such cases.

  9. Identification of beta cell dysfunction at the pre-symptomatic stage of diabetes mellitus by novel analytical system: liquid biopsy measurements in femtograms.

    Science.gov (United States)

    Krapfenbauer, Kurt

    2017-12-01

    Diabetes mellitus is produced and progresses as a consequence of complex and gradual processes, in which a variety of alterations of the endocrine pancreas, are involved and which mainly result in beta cell failure. Those molecular alterations can be found in the bloodstream, which suggests that we could quantify specific biomarkers in plasma or serum by very sensitive methods before the onset diabetes mellitus is diagnosed. However, classical methods of protein analysis such as electrophoresis, Western blot, ELISA, and liquid chromatography are generally time-consuming, lab-intensive, and not sensitive enough to detect such alteration in a pre-symptomatic state of the disease. A very sensitive and novel analytical detection conjugate system by using the combination of polyfluorophor technology with protein microchip method was developed. This innovative system facilitates the use of a very sensitive microchip assays that measure selected biomarkers in a small sample volume (10 μL) with a much higher sensitivity (92%) compare to common immune assay systems. Further advances of the application of this technology combine the power of miniaturization and faster quantification (around 10 min). The power of this technology offers great promise for point-of-care clinical testing and monitoring of specific biomarkers for diabetes in femtogram level in serum or plasma. In conclusion, the results indicate that the technical performance of this new technology is valid and that the assay is able to quantified PPY-specific antigens in plasma at femtogram levels which can be used for identification of beta cell dysfunction at the pre-symptomatic stage of diabetes mellitus.

  10. NEAR INFRARED DIFFUSE INTERSTELLAR BANDS TOWARD THE CYGNUS OB2 ASSOCIATION

    Energy Technology Data Exchange (ETDEWEB)

    Hamano, Satoshi; Kondo, Sohei; Sameshima, Hiroaki; Nakanishi, Kenshi; Kawakita, Hideyo [Laboratory of Infrared High-resolution Spectroscopy, Koyama Astronomical Observatory, Kyoto Sangyo University, Motoyama, Kamigamo, Kita-ku, Kyoto 603-8555 (Japan); Kobayashi, Naoto [Institute of Astronomy, School of Science, University of Tokyo, 2-21-1 Osawa, Mitaka, Tokyo 181-0015 (Japan); Ikeda, Yuji [Photocoding, 460-102 Iwakura-Nakamachi, Sakyo-ku, Kyoto, 606-0025 (Japan); Yasui, Chikako; Mizumoto, Misaki; Matsunaga, Noriyuki; Fukue, Kei; Yamamoto, Ryo; Izumi, Natsuko [Department of Astronomy, Graduate School of Science, University of Tokyo, Bunkyo-ku, Tokyo 113-0033 (Japan); Mito, Hiroyuki [Kiso Observatory, Institute of Astronomy, School of Science, The University of Tokyo, 10762-30 Mitake, Kiso-machi, Kiso-gun, Nagano, 397-0101 (Japan); Nakaoka, Tetsuya; Kawanishi, Takafumi; Kitano, Ayaka; Otsubo, Shogo [Department of Physics, Faculty of Sciences, Kyoto Sangyo University, Motoyama, Kamigamo, Kita-ku, Kyoto 603-8555 (Japan); Kinoshita, Masaomi, E-mail: hamano@cc.kyoto-su.ac.jp [Solar-Terrestrial Environment Laboratory, Nagoya University, Furo-cho, Chikusa-ku, Nagoya, Aichi, 464-8601 (Japan)

    2016-04-10

    We obtained the near-infrared (NIR) high-resolution (R ≡ λ/Δλ ∼ 20,000) spectra of the seven brightest early-type stars in the Cygnus OB2 association for investigating the environmental dependence of diffuse interstellar bands (DIBs). The WINERED spectrograph mounted on the Araki 1.3 m telescope in Japan was used to collect data. All 20 of the known DIBs within the wavelength coverage of WINERED (0.91 < λ < 1.36 μm) were clearly detected along all lines of sight because of their high flux density in the NIR wavelength range and the large extinction. The equivalent widths (EWs) of DIBs were not correlated with the column densities of C{sub 2} molecules, which trace the patchy dense component, suggesting that the NIR DIB carriers are distributed mainly in the diffuse component. On the basis of the correlations among the NIR DIBs both for stars in Cyg OB2 and stars observed previously, λλ10780, 10792, 11797, 12623, and 13175 are found to constitute a “family,” in which the DIBs are correlated well over the wide EW range. In contrast, the EW of λ10504 is found to remain almost constant over the stars in Cyg OB2. The extinction estimated from the average EW of λ10504 (A{sub V} ∼ 3.6 mag) roughly corresponds to the lower limit of the extinction distribution of OB stars in Cyg OB2. This suggests that λ10504 is absorbed only by the foreground clouds, implying that the carrier of λ10504 is completely destroyed in Cyg OB2, probably by the strong UV radiation field. The different behaviors of the DIBs may be caused by different properties of the DIB carriers.

  11. Long-term cultures of testicular biopsies from boys with cryptorchidism

    DEFF Research Database (Denmark)

    Larsen, Hans-Peter Ejler; Thorup, Jørgen; Skovgaard, Lene Theil

    2002-01-01

    BACKGROUND: A long-term culture system of testicular biopsies from boys with undescended testes was established to evaluate the effect of gonadotrophins on germ cell survival and growth. METHODS: Biopsies from 25 boys with cryptorchidism, aged 1.1-9.9 years, were obtained at the time of surgery. ...

  12. Prostate biopsy after ano-rectal resection: value of CT-guided trans-gluteal biopsy

    International Nuclear Information System (INIS)

    Cantwell, Colin P.; Hahn, Peter F.; Gervais, Debra A.; Mueller, Peter R.

    2008-01-01

    We describe our single-institutional experience with computed tomography (CT)-guided percutaneous transgluteal biopsy of the prostate in patients in whom transrectal ultrasound-guided biopsy is precluded by prior ano-rectal resection. Between March 1995 and April 2007, 22 patients had 34 prostate biopsies (mean age 68; mean PSA 29 ng/ml; mean follow-up 6.1 years). The charts of patients who had transgluteal biopsy were reviewed for demographic, complications and pathology. Ninety-five percent (21/22) of primary biopsies were diagnostic. Of the 21 diagnostic biopsies, 11 were positive for prostate cancer and ten were definitive benign samples. Seventy-three percent (8/11) of the patients had progressive PSA elevation that mandated 11 further prostate biopsies. Six patients had a second biopsy, one patient had a third and one patient had a fourth biopsy. Among patients who had serial biopsies, 38% (3/8) had prostate cancer. No complications or death occurred. A malignant biopsy was not significantly associated with core number (P = 0.58) or a high PSA level (P 0.15). CT-guided transgluteal biopsy of the prostate is safe and effective. (orig.)

  13. Comparison between endobronchial forceps-biopsy and cryo-biopsy by flexible

    Directory of Open Access Journals (Sweden)

    Sami El-Dahdouh

    2016-01-01

    Conclusions: We concluded that cryoprobe biopsies were more successful than forceps biopsies in the diagnosis of lung cancer. Nevertheless, further investigations are warranted to determine an efficacy of cryoprobe biopsy procedures and a rationale to use as a part of routine flexible bronchoscopy.

  14. Magnetic field of massive chemically peculiar stars in the Orion OB1 association

    Science.gov (United States)

    Romanyuk, I. I.; Semenko, E. A.; Kudryavtsev, D. O.; Yakunin, I. A.

    2018-01-01

    Spectropolarimetric observations of 55 chemically peculiar stars in the Orion OB1 association were obtained at the 6 m telescope of the Russian Academy of Sciences with the aim of searching for the presence of stellar magnetic fields. We found 8 new magnetic stars in addition to 20 previously known objects. The frequency of chemically peculiar A and B-type stars among normal A and B-type stars and the frequency of magnetic stars among all chemically peculiar stars decreases with age in the Orion OB1 association.

  15. Analyzing the Effects of Nitrogen Deficiency on the PHB Production of Methylosinus trichosporium OB3b

    Science.gov (United States)

    Kyauk, E.

    2011-12-01

    Polyhydroxybutyrate (PHB) is a biodegradable thermoplastic that is produced by various microorganisms. Because of its potential to replace conventional plastics, it has been closely researched in the past few years. Methanotrophic bacteria, bacteria that consume methane, produce this bioplastic when it lacks certain nutrients. The utilization of methane to produce PHB shows much promise as methane is a cheap, plentiful gas. In this study, we observed the methanotroph, Methylosinus trichosporium OB3b , and its yield of PHB in the absence of nitrogen. The optical density of Methylosinus trichosporium OB3b was measured in order to observe cell growth and PHB production patterns over a 48 hour period.

  16. Ultrasonographic findings 6 months after 11-gauge vacuum-assisted large-core breast biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Docktor, B.J.L.; MacGregor, J.H.; Burrowes, P.W. [Foothills Medical Centre, Dept. of Diagnostic Imaging, Calgary, Alberta (Canada)]. E-mail: bobbie.docktor@calgaryhealthregion.ca

    2004-06-01

    To assess the ultrasonographic features of post-biopsy change 6 months after 11-gauge vacuum-assisted large-core breast biopsy of pathologically proven benign lesions. Using the literature as a reference, we hypothesized that large-core breast biopsy would result in tissue changes that may mimic malignancy and may be more apparent on ultrasonography than on mammography. Two radiologists whose subspecialty is breast imaging retrospectively reviewed the pre-biopsy and 6-month follow-up sonograms of 24 patients with pathologically proven benign lesions. The images were assessed for the number and type of ultrasonographic features. A Breast Imaging Reporting and Data System (BI-RADS) category was assigned to each lesion before biopsy and at 6-month follow-up. The composition of breast tissue surrounding the lesion was assessed as fatty, mixed fibroglandular or dense. The frequency of ultrasonographic changes at 6 months after 11-gauge vacuum-assisted large-core breast biopsy was more frequent than the rate of post-biopsy change previously reported to occur mammographically. The nature of these changes may mimic malignancy in some cases. The ultrasonographic appearance of the breast after large-core breast biopsy may mimic malignancy and is, therefore, a potential pitfall when interpreting a post-biopsy sonogram. (author)

  17. Ultrasonographic findings 6 months after 11-gauge vacuum-assisted large-core breast biopsy.

    Science.gov (United States)

    Docktor, Bobbie Jo L; MacGregor, John Henry; Burrowes, Paul W

    2004-06-01

    To assess the ultrasonographic features of post-biopsy change 6 months after 11-gauge vacuum-assisted large-core breast biopsy of pathologically proven benign lesions. Using the literature as a reference, we hypothesized that large-core breast biopsy would result in tissue changes that may mimic malignancy and may be more apparent on ultrasonography than on mammography. Two radiologists whose subspecialty is breast imaging retrospectively reviewed the pre-biopsy and 6-month follow-up sonograms of 24 patients with pathologically proven benign lesions. The images were assessed for the number and type of ultrasonographic features. A Breast Imaging Reporting and Data System (BI-RADS) category was assigned to each lesion before biopsy and at 6-month follow-up. The composition of breast tissue surrounding the lesion was assessed as fatty, mixed fibroglandular or dense. The frequency of ultrasonographic changes at 6 months after 11-gauge vacuum-assisted large-core breast biopsy was more frequent than the rate of post-biopsy change previously reported to occur mammographically. The nature of these changes may mimic malignancy in some cases. The ultrasonographic appearance of the breast after large-core breast biopsy may mimic malignancy and is, therefore, a potential pitfall when interpreting a post-biopsy sonogram.

  18. Ultrasonographic findings 6 months after 11-gauge vacuum-assisted large-core breast biopsy

    International Nuclear Information System (INIS)

    Docktor, B.J.L.; MacGregor, J.H.; Burrowes, P.W.

    2004-01-01

    To assess the ultrasonographic features of post-biopsy change 6 months after 11-gauge vacuum-assisted large-core breast biopsy of pathologically proven benign lesions. Using the literature as a reference, we hypothesized that large-core breast biopsy would result in tissue changes that may mimic malignancy and may be more apparent on ultrasonography than on mammography. Two radiologists whose subspecialty is breast imaging retrospectively reviewed the pre-biopsy and 6-month follow-up sonograms of 24 patients with pathologically proven benign lesions. The images were assessed for the number and type of ultrasonographic features. A Breast Imaging Reporting and Data System (BI-RADS) category was assigned to each lesion before biopsy and at 6-month follow-up. The composition of breast tissue surrounding the lesion was assessed as fatty, mixed fibroglandular or dense. The frequency of ultrasonographic changes at 6 months after 11-gauge vacuum-assisted large-core breast biopsy was more frequent than the rate of post-biopsy change previously reported to occur mammographically. The nature of these changes may mimic malignancy in some cases. The ultrasonographic appearance of the breast after large-core breast biopsy may mimic malignancy and is, therefore, a potential pitfall when interpreting a post-biopsy sonogram. (author)

  19. The NAA system at the reactor BER II clinical analysis of fluorine, calcium, phosphorus and aluminium in bone biopsies, comparison with photon activation analysis and ion sensitive electrode

    International Nuclear Information System (INIS)

    Gawlik, D.; Gatschke, W.; Behne, D.; Braetter, P.

    1981-01-01

    Over the past few years an irradiation and measuring system has been developed for the reactor BER II at the Hahn-Meitner-Institute. It was to be suited in particular to the neutron activation analysis of biological material via short lived radionuclides. The general characteristics of this equipment and some experimental details as the recycling facility and the device used for measuring the irradiation time, the waiting time and the neutron fluency are described. This equipment was used to determine physiological concentrations of the elements sodium, chlorine, aluminium, phosphorus, fluorine, calcium, copper and selenium in biological material. The results have been compared with those obtained by photon activation analysis or ion sensitive electrode. As an example of the application of the apparatus the authors report on the clinical analysis of Ca, F, P and Al in the control of the treatment of patients suffering from osteoporosis. (author)

  20. Ultrasound guided synovial biopsy of the wrist

    NARCIS (Netherlands)

    van Vugt, R. M.; van Dalen, A.; Bijlsma, J. W.

    1997-01-01

    Seven patients (4 female and 3 male, mean age 46) with arthritis of the wrist (n = 7) without known etiology were evaluated. High-definition ultrasound equipment was used for localization of synovial hypertrophy, suitable for ultrasound guided biopsy without risk. A 18-gauge diameter Tru-cut biopsy

  1. Histopathologic quality of prostate core biopsy specimens: comparison of an MR-compatible biopsy needle and a ferromagnetic biopsy needle used for ultrasound-guided prostate biopsy

    International Nuclear Information System (INIS)

    Franiel, T.; Hamm, B.; Beyersdorff, D.; Fritzsche, F.; Staack, A.; Rost, J.

    2006-01-01

    Purpose: The histopathologic quality of core biopsy specimens obtained via MRI-guided prostate biopsy using a 16G MR-compatible needle was compared to that of biopsies obtained via ultrasound-guided biopsy using a conventional 18G stainless steel biopsy needle. Material and Methods: A retrospective analysis was performed for a total of 247 transrectal prostate biopsy specimens obtained from 32 patients. A total of 117 tissue cores were obtained from 15 patients (PSA of 10.8 ng/ml, age 64 years) who underwent an MRI-guided prostate biopsy using a 16G (1.7 mm) MR-compatible biopsy needle made of titanium alloy. The remaining 130 tissue cores were obtained from 17 patients (PSA of 6.7 ng/ml, age 68 years) who underwent a transrectal ultrasound-guided prostate biopsy using an 18G (1.3 mm) ferromagnetic stainless steel biopsy needle. The length and width of the histologic sections prepared from the tissue cores were measured to calculate the area. The histopathologic quality of the specimens was assessed microscopically using tissue fragmentation, the presence of crush artifacts, and the overall assessability as criteria. Each of these features was assigned a score from 0 to 3. All 3 features contributed equally to the overall score which ranged from 0 (no tissue) to 9 (optimal quality). Results: The overall quality scores assigned to the biopsies obtained with a 16G MR-compatible needle and an 18G ferromagnetic needle can be considered to be equivalent to a mean difference between patient related median scores of the specimens of -0.05 (95% confidence interval [-0.46; 0.36]) and a given equivalence limit of 1. The MRI biopsies showed more tissue fragmentation (p=0.001) but fewer crush artifacts (p=0.022) while the assessability did not differ significantly between the two needle types (p=0.064). There was also no significant difference in the calculated areas of the tissue cores (p=0.236). According to the different calibers of the biopsy needles, the lengths (p=0

  2. Cesium-137 global fallout into the Ob river basin and its influence on the Kara sea contamination - Weapons fallout cesium-137 in the Ob' catchment landscapes and its influence on radioactive contamination of the Kara sea: Western Siberia, Russia

    Energy Technology Data Exchange (ETDEWEB)

    Semenkov, Ivan N.; Miroshnikov, Alexey Yu. [The Organization of Russian Academy of Sciences Institute of geology of ore deposits, petrography, mineralogy and geochemistry Russian Academy of Sciences (Russian Federation)

    2014-07-01

    There are several high level {sup 137}Cs anomaly zones detected in the deposits of the SW part of the Kara Sea. These anomaly zones were formed in the Ob' and the Enisey river estuaries due to the geochemical 'river-sea' boarder barrier. Level of radiocaesium specific activity reaches 120 Bq*kg{sup -1} in the deposits from these zones. Radiochemical enterprises occur in the both river basins. Their activity results in caesium-137 transfer into the river net. Vast area is contaminated by {sup 137}Cs after nuclear weapons in Semipalatinsk test-site and Kyshtym disaster in the Ob' river basin. Moreover, caesium comes to the Ob' and the Enisey river basins with global atmospheric fallout. The inflow of global fallout caesium-137 to the catchments is 660 kCi (320 kCi including radioactive decay) that is 4 times higher than {sup 137}Cs emission due to Fukushima disaster. Therefore, these river basins as any other huge catchment are an important sources of radioactive contamination of the Arctic Ocean. The aim of our research is to study behavior of global fallout caesium-137 in the landscapes of the Ob and the Enisey river basins. We studied caesium-137 behavior on the example of first order catchments in taiga, wetland, forest-steppe, steppe, and semi-arid landscapes. Geographic information system (GIS) was made. The tenth-order catchments (n=154, Horton coding system) shape 20-groups due to topsoil properties controlling cesium mobility. Eleven first-order basins, characterized 7 groups of tenth order catchments, were studied. And 700 bulk-core soil samples were collected in 2011-2013. Cesium runoff is calculated for 3 first-order river basins in taiga and forest-steppe landscapes. Storage of global fallout caesium-137 declines from undisturbing taiga first-order river basin (90% of cumulative fallout including radioactive decay)> arable steppe and fores-steppe (70 - 75%)> undisturbing wetland (60%). Caesium-137 transfer is high in arable lands

  3. Coeliac disease: to biopsy or not?

    Science.gov (United States)

    Reilly, Norelle R; Husby, Steffen; Sanders, David S; Green, Peter H R

    2018-01-01

    Coeliac disease is increasingly recognized as a global problem in both children and adults. Traditionally, the findings of characteristic changes of villous atrophy and increased intraepithelial lymphocytosis identified in duodenal biopsy samples taken during upper gastrointestinal endoscopy have been required for diagnosis. Although biopsies remain advised as necessary for the diagnosis of coeliac disease in adults, European guidelines for children provide a biopsy-sparing diagnostic pathway. This approach has been enabled by the high specificity and sensitivity of serological testing. However, these guidelines are not universally accepted. In this Perspective, we discuss the pros and cons of a biopsy-avoiding pathway for the diagnosis of coeliac disease, especially in this current era of the call for more biopsies, even from the duodenal bulb, in the diagnosis of coeliac disease. In addition, a contrast between paediatric and adult guidelines is presented.

  4. Usefulness of CT fluoroscopy-guided percutaneous needle biopsy in the presence of pneumothorax during biopsy

    International Nuclear Information System (INIS)

    O, Dong Hyun; Cho, Young Jun; Park, Yong Sung; Hwang, Cheol Mok; Kim, Keum Won; Kim, Ji Hyung

    2006-01-01

    When pneumothorax occurs during a percutaneous needle biopsy, the radiologist usually stops the biopsy. We evaluated the usefulness of computed tomographic (CT) fluoroscopy-guided percutaneous needle biopsy in the presence of pneumothorax during biopsy. We performed 288 CT fluoroscopy guided percutaneous needle biopsies to diagnose the pulmonary nodules. Twenty two of these patients had pneumothorax that occurred during the biopsy without obtaining an adequate specimen. After pneumothorax occurred, we performed immediate CT fluoroscopy guided percutaneous needle biopsies using an 18-gauge cutting needle. We evaluated the success rate of the biopsies and also whether or not the pneumothorax progressed. We classified these patients into two groups according to whether the pneumothorax progressed (Group 2) or not (Group 1) by measuring the longest distance between the parietal pleura and the visceral pleura both in the early and late pneumothorax. Additionally, we analyzed the relationship between the progression of pneumothorax after biopsy and 1) the depth of the pulmonary nodule; 2) the number of biopsies; 3) the presence or absence of emphysema at the biopsy site; and 4) the size of the pulmonary nodule. Biopsy was successful in 19 of 22 nodules (86.3%). Of the 19 nodules, 12 (63.2%) were malignant and 7 (36.8%) were benign. Twelve patients (54.5%) were classified as group 1 and 10 patients (45.4%) as group 2. The distance between the lung lesion and pleura showed a statistically significant difference between these two groups: ≤ 1 cm in distance for group 1 (81.8%) and group 2 (18.2%), and > 1 cm in distance for group 1 (30%) and group 2 (70%), ρ 0.05). When early pneumothorax occurs during a biopsy, CT fluoroscopy guided percutaneous needle biopsy is an effective and safe procedure. Aggravation of pneumothorax after biopsy is affected by the depth of the pulmonary nodule

  5. [D-Leu-4]-OB3 and MA-[D-Leu-4]-OB3, small molecule synthetic peptide leptin mimetics, improve glycemic control in diet-induced obese (DIO) mice.

    Science.gov (United States)

    Wang, Anke; Anderson, Brian M; Novakovic, Zachary M; Grasso, Patricia

    2018-03-01

    We have previously shown that following oral delivery in dodecyl maltoside (DDM), [D-Leu-4]-OB3 and its myristic acid conjugate, MA-[D-Leu-4]-OB3, improved energy balance and glucose homeostasis in genetically obese/diabetic mouse models. More recently, we have provided immunohistochemical evidence indicating that these synthetic peptide leptin mimetics cross the blood-brain barrier and concentrate in the area of the arcuate nucleus of the hypothalamus in normal C57BL/6J and Swiss Webster mice, in genetically obese ob/ob mice, and in diet-induced obese (DIO) mice. In the present study, we describe the effects of oral delivery of [D-Leu-4]-OB3 and MA-[D-Leu-4]-OB3 on glycemic control in diet-induced (DIO) mice, a non-genetic rodent model of obesity and its associated insulin resistance, which more closely recapitulates common obesity and diabetes in humans. Male C57BL/6J and DIO mice, 17, 20, and 28 weeks of age, were maintained on a low-fat or high-fat diet and given vehicle (DDM) alone or [D-Leu-4]-OB3 or MA-[D-Leu-4]-OB3 in DDM by oral gavage for 12 or 14 days. Body weight gain, food and water intake, fasting blood glucose, oral glucose tolerance, and serum insulin levels were measured. Our data indicate that (1) [D-Leu-4]-OB3 and MA-[D-Leu-4]-OB3 restore glucose tolerance in male DIO mice maintained on a high-fat diet to levels comparable to those of non-obese C57BL/6J wild-type mice of the same age and sex maintained on a low-fat diet; and (2) the influence of [D-Leu-4]-OB3 and MA-[D-Leu-4]-OB3 on glycemic control appears to be independent of their effects on energy balance. These results suggest that [D-Leu-4]-OB3 and/or MA-[D-Leu-4]-OB3 may have application to the management of the majority of cases of common obesity in humans, a state characterized at least in part, by leptin resistance resulting from a defect in leptin transport across the blood-brain barrier. They further suggest that these small molecule synthetic peptide leptin mimetics, through their

  6. Breast carcinoma in radiosurgery biopsy

    International Nuclear Information System (INIS)

    Cohen, Leonard O.; Brito, Pablo E.; Coppolecchia, German L.; Giarmana, Maria J.; Delle Ville, Rodolfo E.; Cortese, Eduardo M.

    2006-01-01

    Purpose: To report our experience on the detection of breast cancer (BC) through guided radiosurgical biopsies (GRSB) in the Gynecology Department of the Hospital Aeronautico Central (SGHAC). Materials and method: We retrospectively analyzed 622 GRSBs performed at the SGHAC between 1 January 1995 and 31 December 2004. We took into account single or associated lesions found in mammograms, which we subdivided into four types: 1) Non-palpable mammographic nodules; 2) Microcalcifications; 3) Structural distortions; 4) Mammographic asymmetries. Results: We found 332 non-palpable nodules (53.4%), 214 microcalcifications (34.4%), 40 structural distortions (6.4%), and 36 mammographic asymmetries (5.8%). Out of the 622 GRSBs performed during the above period, 152 BCs were diagnosed, that is, an incidence of 24.4% detected through this method. Out of the 152 BCs, 110 (72.4%) were invasive and 42 (27.6%) were noninvasive. Conclusions: Although 24.4% of BCs were identified through GRSBs, our tea m considers this to be the standard method for early detection of breast cancer. (author) [es

  7. Comparison of CT and PET/CT for biopsy guidance in oncological patients

    International Nuclear Information System (INIS)

    Cerci, Juliano J.; Bogoni, Mateos; Cunha Pereira, Carlos; Cerci, Rodrigo J.; Krauzer, Cassiano; Vicente Vitola, Joao; Tabacchi, Elena; Fanti, Stefano; Delbeke, Dominique; Giacometti Sakamoto, Danielle

    2017-01-01

    To compare FDG PET/CT and CT for the guidance of percutaneous biopsies with histological confirmation of lesions. We prospectively evaluated 323 patients of whom 181 underwent FDG PET/CT-guided biopsy (total 188 biopsies) and 142 underwent CT-guided biopsy (total 146 biopsies). Biopsies were performed using the same PET/CT scanner with a fluoroscopic imaging system. Technical feasibility, clinical success and complication rates in the two groups were evaluated. Of the 188 biopsies with PET/CT guidance, 182 (96.8%) were successful with conclusive tissue samples obtained and of the 146 biopsies with CT guidance, 137 (93.8%) were successful. Therefore, 6 of 188 biopsies (3.1%) with PET/CT guidance and 9 of 146 (6.1%) with CT guidance were inconclusive (p = 0.19). Due to inconclusive histological results, 4 of the 188 lesions (2.1%) were rebiopsied with PET/CT guidance and 3 of 146 lesions (2.0%) were rebiopsied with CT guidance. Histology demonstrated that 142 of 188 lesions (75.5%) were malignant, and 40 (21.2%) were benign in the PET/CT-guided group, while 89 of 146 lesions (60.9%) were malignant and 48 (32.8%) were benign in the CT-guided group (p = 0.004 and 0.01, respectively). Patients with a histological diagnosis of benign lesion had no recurrence of disease with a minimum of 6 months follow-up. Of the 188 PET/CT-guided biopsies, 6 (3.1%) were repeat biopsies due to a previous nondiagnostic CT-guided biopsy performed in a different diagnostic centre. The interval between the two biopsies was less than a month in all cases. Histology revealed five malignant lesions and one benign lesion among these. The complication rate in the PET/CT-guided biopsy group was 12.7% (24 of 188), while in the CT-guided group, was 9.5% (14 of 146, p = 0.26). Therefore, there was no significant difference in complication rates between PET/CT and CT guidance. PET/CT-guided biopsy is already known to be a feasible and accurate method in the diagnostic work-up of suspected malignant

  8. Comparison of CT and PET/CT for biopsy guidance in oncological patients

    Energy Technology Data Exchange (ETDEWEB)

    Cerci, Juliano J.; Bogoni, Mateos; Cunha Pereira, Carlos; Cerci, Rodrigo J.; Krauzer, Cassiano; Vicente Vitola, Joao [Quanta - Diagnostico e Terapia, Curitiba, PR (Brazil); Tabacchi, Elena; Fanti, Stefano [University Hospital S. Orsola-Malpighi, Nuclear Medicine Department, Bologna (Italy); Delbeke, Dominique [Vanderbilt University, Nashville, TN (United States); Giacometti Sakamoto, Danielle [Byori - Laboratorio de Patologia, Curitiba (Brazil)

    2017-08-15

    To compare FDG PET/CT and CT for the guidance of percutaneous biopsies with histological confirmation of lesions. We prospectively evaluated 323 patients of whom 181 underwent FDG PET/CT-guided biopsy (total 188 biopsies) and 142 underwent CT-guided biopsy (total 146 biopsies). Biopsies were performed using the same PET/CT scanner with a fluoroscopic imaging system. Technical feasibility, clinical success and complication rates in the two groups were evaluated. Of the 188 biopsies with PET/CT guidance, 182 (96.8%) were successful with conclusive tissue samples obtained and of the 146 biopsies with CT guidance, 137 (93.8%) were successful. Therefore, 6 of 188 biopsies (3.1%) with PET/CT guidance and 9 of 146 (6.1%) with CT guidance were inconclusive (p = 0.19). Due to inconclusive histological results, 4 of the 188 lesions (2.1%) were rebiopsied with PET/CT guidance and 3 of 146 lesions (2.0%) were rebiopsied with CT guidance. Histology demonstrated that 142 of 188 lesions (75.5%) were malignant, and 40 (21.2%) were benign in the PET/CT-guided group, while 89 of 146 lesions (60.9%) were malignant and 48 (32.8%) were benign in the CT-guided group (p = 0.004 and 0.01, respectively). Patients with a histological diagnosis of benign lesion had no recurrence of disease with a minimum of 6 months follow-up. Of the 188 PET/CT-guided biopsies, 6 (3.1%) were repeat biopsies due to a previous nondiagnostic CT-guided biopsy performed in a different diagnostic centre. The interval between the two biopsies was less than a month in all cases. Histology revealed five malignant lesions and one benign lesion among these. The complication rate in the PET/CT-guided biopsy group was 12.7% (24 of 188), while in the CT-guided group, was 9.5% (14 of 146, p = 0.26). Therefore, there was no significant difference in complication rates between PET/CT and CT guidance. PET/CT-guided biopsy is already known to be a feasible and accurate method in the diagnostic work-up of suspected malignant

  9. The Shift From Sentinel Lymph Node Biopsy Performed Either Before or After Neoadjuvant Systemic Therapy in the Clinical Negative Nodes of Breast Cancer Patients. Results, and the Advantages and Disadvantages of Both Procedures.

    Science.gov (United States)

    Fernandez-Gonzalez, Sergi; Falo, Catalina; Pla, Maria Jesus; Pernas, Sonia; Bajen, Maite; Soler, Teresa; Ortega, Raul; Quetglas, Cecilia; Perez-Martin, Xavier; Fernandez Montoli, Maria Eulalia; Campos, Miriam; Varela-Rodriguez, Mar; Ponce, Jordi; Garcia-Tejedor, Amparo

    2018-02-01

    In patients with breast cancer who are candidates for neoadjuvant therapy (NAT), the timing of when to perform sentinel lymph node biopsy (SLNB) remains under discussion. The aim of this study was to compare the advantages and disadvantages of SLNB performed before and after NAT. One hundred seventy-two patients, T1c to T3 and N0 (clinically and according to ultrasound) candidates for NAT were included. We compared the outcomes of 2 groups: (1) 122 patients of whom SLNB was performed before NAT (pre-NAT) from December 2006 to April 2014; and (2) 50 patients with SLNB performed after NAT (post-NAT) from May 2014 to July 2016. Both groups were homogeneous in baseline patient characteristics. The SLNB was positive in 50 patients [41.7%] (33 macrometastases [66%] and 17 micrometastases [34%]) versus 6 patients [12%] (5 macrometastases [83.3%] and 1 micrometastases [16.7%]) in pre- and post-NAT groups, respectively. The lymphadenectomy was performed in 34 patients [28.3%] versus 4 patients [8%], with an odds ratio of 3.48 (95% confidence interval, 1.3-9.3). The recurrences in the pre-NAT group after a median follow-up of 62 months were 12 systemic, 2 local and systemic, and none axillary. In the post-NAT group were no recurrences after a median follow-up of 16 months. Finally, SLNB after NAT reduces the delay in starting NAT from 24 to 14 days (medians; P < .001) and the identification of the SLNB was in 122 patients [100%] versus 49 patients [98%]. SLNB performed after NAT significantly reduces the rate of lymphadenectomies without any increase in recurrences at early follow-up. Furthermore, it allows systemic treatment to be started earlier without interfering in the SLNB identification rate. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. CARINA OB STARS: X-RAY SIGNATURES OF WIND SHOCKS AND MAGNETIC FIELDS

    International Nuclear Information System (INIS)

    Gagne, Marc; Fehon, Garrett; Savoy, Michael R.; Cohen, David H.; Townsley, Leisa K.; Broos, Patrick S.; Povich, Matthew S.; Corcoran, Michael F.; Walborn, Nolan R.; Remage Evans, Nancy; Moffat, Anthony F. J.; Naze, Yael; Oskinova, Lida M.

    2011-01-01

    The Chandra Carina Complex contains 200 known O- and B-type stars. The Chandra survey detected 68 of the 70 O stars and 61 of 127 known B0-B3 stars. We have assembled a publicly available optical/X-ray database to identify OB stars that depart from the canonical L X /L bol relation or whose average X-ray temperatures exceed 1 keV. Among the single O stars with high kT we identify two candidate magnetically confined wind shock sources: Tr16-22, O8.5 V, and LS 1865, O8.5 V((f)). The O4 III(fc) star HD 93250 exhibits strong, hard, variable X-rays, suggesting that it may be a massive binary with a period of >30 days. The visual O2 If* binary HD 93129A shows soft 0.6 keV and hard 1.9 keV emission components, suggesting embedded wind shocks close to the O2 If* Aa primary and colliding wind shocks between Aa and Ab. Of the 11 known O-type spectroscopic binaries, the long orbital-period systems HD 93343, HD 93403, and QZ Car have higher shock temperatures than short-period systems such as HD 93205 and FO 15. Although the X-rays from most B stars may be produced in the coronae of unseen, low-mass pre-main-sequence companions, a dozen B stars with high L X cannot be explained by a distribution of unseen companions. One of these, SS73 24 in the Treasure Chest cluster, is a new candidate Herbig Be star.

  11. US-guided biopsy of renal allografts using 18G biopsy gun: analysis of 200 cases

    International Nuclear Information System (INIS)

    Kim, Eun Kyung; Lee, Jong Tae; Kim, Myeong Jin; Yoo, Hyung Sik; Kim, Ki Whang; Park, Ki Ill; Chung, Hyun Joo

    1995-01-01

    We evaluated the effectiveness and safety of 18G biopsy gun with US guidance in the transplanted kidneys. We performed 200 US-guided percutaneous biopsies using 18G biopsy gun. Diagnostic efficacy and complication of the biopsy in these patients were analyzed. Biopsy specimens were adequate for histologic diagnoses in 193 patients(96.5%). The mean of the biopsy frequency was 3, the mean of total glomerular number was 21.64 and the mean glomerular number per one biopsy was 6.93. Major complications occurred in 3 (1.5%) of the 200 biopsies; hematuria developed in two patients, AV fistula in one. These complications were successfully controlled either by only transfusion or by coil embolization. There were no statistical differences in blood pressure, hemoglobin, BUN/Cr between pre-and post-renal biopsies. US-guided percutaneous biopsy of renal allograft with 18G biopsy gun is simple, safe, and accurate method in evaluating the renal allograft dysfunction

  12. Conversion of chlorinated propanes by Methylosinus trichosporium OB3b expressing soluble methane monooxygenase

    NARCIS (Netherlands)

    Bosma, T.; Janssen, D.B.

    Chlorinated propanes are important pollutants that may show persistent behaviour in the environment. The biotransformation of 1-chloropropane, 1,2-dichloropropane, 1,3-dichloropropane and 1,2,3-trichloropropane was studied using resting cell suspensions of Methylosinus trichosporium OB3b expressing

  13. Formation of massive stars in OB associations and giant molecular clouds

    International Nuclear Information System (INIS)

    Lada, C.J.

    1980-01-01

    Certain interesting patterns are being perceived in the morphology of the regions which have recently produced massive OB stars. In particular, current evidence seems to favour the notion that the formation of massive stars takes place at the edges and not the centres of large molecular cloud complexes. It is this aspect of the observations that is discussed in the present paper. The phenomena described here will pertain to massive stars only. Specifically, stars with spectral types earlier than B3 will be considered since it is usually only these stars that produce sufficient havoc (e.g., maser sources, CO bright spots, H II regions) to noticeably affect their early environments. The corresponding phenomena for lower mass stars could be entirely different. A review is first presented of what has been learned about the OB star formation process from studies of the visible OB stars themselves. Then, newly derived information pertaining to the most recent episodes of OB star birth in galactic molecular clouds is discussed. Finally, a short discussion of the significance of the results and their implications for possible star formation mechanisms will be made. (U.K.)

  14. Degradation of Chlorinated Aliphatic Hydrocarbons by Methylosinus trichosporium OB3b Expressing Soluble Methane Monooxygenase

    NARCIS (Netherlands)

    Oldenhuis, R.; Vink, Ruud L.J.M.; Janssen, D. B.; Witholt, B.

    1989-01-01

    Degradation of trichloroethylene (TCE) by the methanotrophic bacterium Methylosinus trichosporium OB3b was studied by using cells grown in continuous culture. TCE degradation was a strictly cometabolic process, requiring the presence of a cosubstrate, preferably formate, and oxygen. M. trichosporium

  15. Inter-Division IV/V WG on Active OB Stars

    NARCIS (Netherlands)

    Owocki, S.; Aerts, C.; Fabregat, J.; Gies, D.; Henrichs, H.F.; McDavid, D.; Porter, J.; Rivinius, T.; Peters, G.; Stefl, S.

    2007-01-01

    Our group studies active early-type (OB) stars, with historical focus on classical Be stars, but extending in recent years to include Slowly Pulsating B-stars (SPB), Beta-Cephei stars, the strongly magnetic Bp stars, Luminous Blue Vairiable (LBV) stars, and B[e] stars. An overall goal is to

  16. Kinetics of Chlorinated Hydrocarbon Degradation by Methylosinus trichosporium OB3b and Toxicity of Trichloroethylene

    NARCIS (Netherlands)

    Oldenhuis, Roelof; Oedzes, Johannes Y.; Waarde, Jacob J. van der; Janssen, Dick B.

    The kinetics of the degradation of trichloroethylene (TCE) and seven other chlorinated aliphatic hydrocarbons by Methylosinus trichosporium OB3b were studied. All experiments were performed with cells grown under copper stress and thus expressing soluble methane monooxygenase. Compounds that were

  17. VizieR Online Data Catalog: Velocity and proper motion of OB associations (Melnik+, 2009)

    Science.gov (United States)

    Melnik, A. M.; Dambis, A. K.

    2009-11-01

    For every OB-association from the list by Blaha and Humphreys (1989AJ.....98.1598B) we give the mean galactic coordinates l and b, the mean heliocentric distance r, median line-of-sight velocity Vr, the dispersion of line-of-sight velocities dvr, and number of stars with known line-of-sight velocity nvr. The line-of-sight velocities were taken from the catalog by Barbier-Brossat and Figon (1999, Cat. ). We used only the velocities measured with errors of less than 10km/s which corresponds to the quality estimations A, B, and C. We also present median proper motions of OB-associations along l- and b- coordinates, mul and mub. The data obtained for the old reduction (1997, Cat. ) are denoted by the subscript 1, whereas those based on the reduction by van Leewen (2008, Cat. ) are marked by the subscript 2. For each OB association we represent the dispersions of proper motions, dml and dmb, as well as a number of stars nmu with known proper motion. The last column shows the total number of stars with known photometric measurements, Nt, used for determination of the distances for OB-associations. The distances r correspond to the short distance scale for classical Cepheids. They are equal to the distances from the catalog by Blaha and Humphreys (1989AJ.....98.1598B), rBH, multiplied by a factor of 0.8, r=0.8*rBH. (1 data file).

  18. ObsPack: a framework for the preparation, delivery, and attribution of atmospheric greenhouse gas data

    NARCIS (Netherlands)

    Masarie, K. A.; Peters, W.; Jacobson, A. R.; Tans, P. P.

    2014-01-01

    Observation Package (ObsPack) is a framework designed to bring together atmospheric greenhouse gas observations from a variety of sampling platforms, prepare them with specific applications in mind, and package and distribute them in a self-consistent and well-documented product. Data products

  19. ObsPack: a framework for the preparation, delivery, and attribution of atmospheric greenhouse gas measurements

    NARCIS (Netherlands)

    Masarie, K. A.; Peters, W.; Jacobson, A. R.; Tans, P. P.

    2014-01-01

    Observation Package (ObsPack) is a framework designed to bring together atmospheric greenhouse gas observations from a variety of sampling platforms, prepare them with specific applications in mind, and package and distribute them in a self-consistent and well-documented product. Data products

  20. Effect of chlorinated ethene conversion on viability and activity of Methylosinus trichosporium OB3b

    NARCIS (Netherlands)

    van Hylckama Vlieg, Johan E.T.; Koning, Wim de; Janssen, Dick B.

    1997-01-01

    The effect of transformation of chlorinated ethenes on the cell viability of Methylosinus trichosporium OB3b was investigated. A comparison of the loss of viability with the decrease in transformation rates shelved that for the monooxygenase-mediated transformation of all chlorinated ethenes except

  1. Analytical model of a burst assembly algorithm for the VBR in the OBS networks

    International Nuclear Information System (INIS)

    Shargabi, M.A.A.; Mellah, H.; Abid, A.

    2008-01-01

    This paper presents a proposed analytical model for the number of bursts aggregated in a period of time in OBS networks. The model considers the case of VBR traffic with two different sending rates, which are SCR and PCR. The model is validated using extensive simulations. Where results from simulations are in total agreement with the results obtained by the proposed model. (author)

  2. BOREAS TF-3 NSA-OBS Tower Flux, Meteorological, and Soil Temperature Data

    Science.gov (United States)

    Wofsy, Steven; Sutton, Doug; Goulden, Mike; Hall, Forrest G. (Editor); Huemmrich, Karl (Editor)

    2000-01-01

    The BOReal Ecosystem-Atmosphere Study Tower Flux (BOREAS TF-3) team collected tower flux, surface meteorological, and soil temperature data at the BOREAS Northern Study Area-Old Black Spruce (NSA-OBS) site continuously from the March 1994 through October 1996. The data are available in tabular ASCII files.

  3. Transvenous liver biopsy via the femoral vein

    International Nuclear Information System (INIS)

    Khosa, F.; McNulty, J.G.; Hickey, N.; O'Brien, P.; Tobin, A.; Noonan, N.; Ryan, B.; Keeling, P.W.N.; Kelleher, D.P.; McDonald, G.S.A.

    2003-01-01

    AIM: To study the safety, effectiveness and diagnostic value of transvenous forceps biopsy of the liver in 54 patients with coagulopathy, gross ascites or morbid obesity and suspected liver disease in whom percutaneous liver biopsy was contraindicated. MATERIAL AND METHODS: Forceps biopsy of the liver via the femoral vein was attempted in 54 adult patients with advanced liver disease of unknown aetiology who had coagulation disorders (41 cases), gross ascites (11 cases) or morbid obesity (two cases). In each patient two to six biopsies (average four) were taken using a radial jaw forceps inserted via the right or left femoral vein. RESULTS: The procedure was successful in 53 cases. Hepatic vein catheterization failed in one patient. Adequate liver tissue for diagnosis was obtained in 84% of cases. One patient developed delayed haemorrhage at 12 h from a capsular leak that was undetected during the biopsy procedure. This patient required blood transfusions and laparotomy to control bleeding. There were no deaths in the 53 patients studied. Transient minor chest and shoulder pain was encountered during sheath insertion into a hepatic vein in 23 patients. Three patients developed a femoral vein haematoma, which resolved with conservative treatment. CONCLUSION: Transvenous liver biopsy via the femoral vein is another safe, effective, simple alternative technique of biopsy when the percutaneous route is contraindicated

  4. Effects of copper mineralogy and methanobactin on cell growth and sMMO activity in Methylosinus trichosporium OB3b

    Directory of Open Access Journals (Sweden)

    C. Dennison

    2011-10-01

    Full Text Available Controls on in situ methanotroph activity are not well understood. One potentially important parameter is copper (Cu because it is the metal-centre of particulate methane monooxygenase (pMMO, the most active enzyme for oxidizing methane to methanol. Further, Cu-to-cell ratios influence the relative expression of pMMO versus the alternate soluble MMO (sMMO in some species. However, most methanotroph studies only have assessed readily soluble forms of Cu (e.g. CuCl2 and there is a dearth of Cu-related activity data for Cu sources more common in the environment. Here we quantified sMMO activity (as a practical indicator of Cu availability and growth kinetics in Methylosinus trichosporium OB3b, an organism that expresses both pMMO and sMMO, when grown on Cu-minerals with differing dissolution equilibria to assess how mineral type and methanobactin (mb might influence in situ methanotroph activity. Mb is a molecule produced by M. trichosporium OB3b that has a high affinity for Cu, reduces Cu toxicity, and may influence Cu availability in terrestrial systems. CuCO3.Cu(OH2 and CuO were chosen for study based on modelling data, reflecting more and less soluble minerals, respectively, and were found to affect M. trichosporium OB3b activity differently. Cells grew without growth lag and with active pMMO on CuCO3.Cu(OH2, regardless of the amount of mineral supplied (−1. The organism also grew well on CuO; however, significant sMMO activity was retained up to 50 μmoles Cu-total l−1, although sMMO activity was suppressed by supplemental mb and-or direct cell-mineral contact. Mb addition increased growth rates (p < 0.05 with both minerals. Results show mb broadly stimulates growth, but Cu mineralogy and mb dictate whether sMMO or pMMO is active in the cells. This explains why sMMO activity has been seen in soils with high Cu and also has implications for predicting dominant MMO activity in terrestrial bioremediation applications.

  5. The Overt Behaviour Scale-Self-Report (OBS-SR) for acquired brain injury: exploratory analysis of reliability and validity.

    Science.gov (United States)

    Kelly, Glenn; Simpson, Grahame K; Brown, Suzanne; Kremer, Peter; Gillett, Lauren

    2017-05-23

    The objectives were to test the properties, via a psychometric study, of the Overt Behaviour Scale-Self-Report (OBS-SR), a version of the OBS-Adult Scale developed to provide a client perspective on challenging behaviours after acquired brain injury. Study sample 1 consisted of 37 patients with primary brain tumour (PBT) and a family-member informant. Sample 2 consisted of 34 clients with other acquired brain injury (mixed brain injury, MBI) and a service-provider informant. Participants completed the OBS-SR (at two time points), and the Awareness Questionnaire (AQ) and Mayo Portland Adaptability Inventory-III (MPAI-III) once; informants completed the OBS-Adult and AQ once only. PBT-informant dyads displayed "good" levels of agreement (ICC 2,k  = .74; OBS-SR global index). Although MBI-informant dyads displayed no agreement (ICC 2,k  = .22; OBS-SR global index), the sub-group (17/29) rated by clinicians as having moderate to good levels of awareness displayed "fair" agreement (ICC 2,k  = .58; OBS-SR global index). Convergent/divergent validity was demonstrated by significant correlations between OBS-SR subscales and MPAI-III subscales with behavioural content (coefficients in the range .36 -.61). Scores had good reliability across one week (ICC 2,k  = .69). The OBS-SR took approximately 15 minutes to complete. It was concluded that the OBS-SR demonstrated acceptable reliability and validity, providing a useful resource in understanding clients' perspectives about their behaviour.

  6. Psoriasis skin biopsy image segmentation using Deep Convolutional Neural Network.

    Science.gov (United States)

    Pal, Anabik; Garain, Utpal; Chandra, Aditi; Chatterjee, Raghunath; Senapati, Swapan

    2018-06-01

    Development of machine assisted tools for automatic analysis of psoriasis skin biopsy image plays an important role in clinical assistance. Development of automatic approach for accurate segmentation of psoriasis skin biopsy image is the initial prerequisite for developing such system. However, the complex cellular structure, presence of imaging artifacts, uneven staining variation make the task challenging. This paper presents a pioneering attempt for automatic segmentation of psoriasis skin biopsy images. Several deep neural architectures are tried for segmenting psoriasis skin biopsy images. Deep models are used for classifying the super-pixels generated by Simple Linear Iterative Clustering (SLIC) and the segmentation performance of these architectures is compared with the traditional hand-crafted feature based classifiers built on popularly used classifiers like K-Nearest Neighbor (KNN), Support Vector Machine (SVM) and Random Forest (RF). A U-shaped Fully Convolutional Neural Network (FCN) is also used in an end to end learning fashion where input is the original color image and the output is the segmentation class map for the skin layers. An annotated real psoriasis skin biopsy image data set of ninety (90) images is developed and used for this research. The segmentation performance is evaluated with two metrics namely, Jaccard's Coefficient (JC) and the Ratio of Correct Pixel Classification (RCPC) accuracy. The experimental results show that the CNN based approaches outperform the traditional hand-crafted feature based classification approaches. The present research shows that practical system can be developed for machine assisted analysis of psoriasis disease. Copyright © 2018 Elsevier B.V. All rights reserved.

  7. TOWARD COMPLETE STATISTICS OF MASSIVE BINARY STARS: PENULTIMATE RESULTS FROM THE CYGNUS OB2 RADIAL VELOCITY SURVEY

    Energy Technology Data Exchange (ETDEWEB)

    Kobulnicky, Henry A.; Lundquist, Michael J.; Burke, Jamison; Chapman, James; Keller, Erica; Lester, Kathryn; Rolen, Emily K.; Topel, Eric; Bhattacharjee, Anirban; Smullen, Rachel A.; Álvarez, Carlos A. Vargas; Runnoe, Jessie C.; Dale, Daniel A.; Brotherton, Michael M. [Department of Physics and Astronomy, University of Wyoming, Laramie, WY 82070 (United States); Kiminki, Daniel C., E-mail: chipk@uwyo.edu, E-mail: jburke2@swarthmore.edu, E-mail: jc6380@mcla.edu, E-mail: kelle22e@mtholyoke.edu, E-mail: kvl214@lehigh.edu, E-mail: emily.k.rolen@vanderbilt.edu, E-mail: topel@stolaf.edu [Department of Astronomy, University of Arizona, Tucson, AZ 85721 (United States)

    2014-08-01

    We analyze orbital solutions for 48 massive multiple-star systems in the Cygnus OB2 association, 23 of which are newly presented here, to find that the observed distribution of orbital periods is approximately uniform in log P for P < 45 days, but it is not scale-free. Inflections in the cumulative distribution near 6 days, 14 days, and 45 days suggest key physical scales of ≅0.2, ≅0.4, and ≅1 A.U. where yet-to-be-identified phenomena create distinct features. No single power law provides a statistically compelling prescription, but if features are ignored, a power law with exponent β ≅ –0.22 provides a crude approximation over P = 1.4-2000 days, as does a piece-wise linear function with a break near 45 days. The cumulative period distribution flattens at P > 45 days, even after correction for completeness, indicating either a lower binary fraction or a shift toward low-mass companions. A high degree of similarity (91% likelihood) between the Cyg OB2 period distribution and that of other surveys suggests that the binary properties at P ≲ 25 days are determined by local physics of disk/clump fragmentation and are relatively insensitive to environmental and evolutionary factors. Fully 30% of the unbiased parent sample is a binary with period P < 45 days. Completeness corrections imply a binary fraction near 55% for P < 5000 days. The observed distribution of mass ratios 0.2 < q < 1 is consistent with uniform, while the observed distribution of eccentricities 0.1 < e < 0.6 is consistent with uniform plus an excess of e ≅ 0 systems. We identify six stars, all supergiants, that exhibit aperiodic velocity variations of ∼30 km s{sup –1} attributed to atmospheric fluctuations.

  8. Die Biopsie von Knochen- und Weichteiltumoren

    OpenAIRE

    Fuchs, B

    2008-01-01

    Technisch stellt die Biopsie von Knochen- und Weichteiltumoren einen simplen Akt dar, intellektuell aber ist die Planung einer Biopsie höchst anspruchsvoll. Zu häufig werden heutzutage immer noch Biopsien unsachgemäss durchgeführt, so dass die Behandlung - im besten Fall - erschwert wird. Eine unsachgemäss durchgeführte Biopsie führt häufig zu negativen funktionellen Konsequenzen für den Patienten, im schlimmsten Fall kann es die Prognose direkt beeinträchtigen. Aus diesem Grund soll...

  9. ObsPy: A Python toolbox for seismology - Sustainability, New Features, and Applications

    Science.gov (United States)

    Krischer, L.; Megies, T.; Sales de Andrade, E.; Barsch, R.; MacCarthy, J.

    2016-12-01

    ObsPy (https://www.obspy.org) is a community-driven, open-source project dedicated to offer a bridge for seismology into the scientific Python ecosystem. Amongst other things, it provides Read and write support for essentially every commonly used data format in seismology with a unified interface. This includes waveform data as well as station and event meta information. A signal processing toolbox tuned to the specific needs of seismologists. Integrated access to the largest data centers, web services, and databases. Wrappers around third party codes like libmseed and evalresp. Using ObsPy enables users to take advantage of the vast scientific ecosystem that has developed around Python. In contrast to many other programming languages and tools, Python is simple enough to enable an exploratory and interactive coding style desired by many scientists. At the same time it is a full-fledged programming language usable by software engineers to build complex and large programs. This combination makes it very suitable for use in seismology where research code often must be translated to stable and production ready environments, especially in the age of big data. ObsPy has seen constant development for more than six years and enjoys a large rate of adoption in the seismological community with thousands of users. Successful applications include time-dependent and rotational seismology, big data processing, event relocations, and synthetic studies about attenuation kernels and full-waveform inversions to name a few examples. Additionally it sparked the development of several more specialized packages slowly building a modern seismological ecosystem around it. We will present a short overview of the capabilities of ObsPy and point out several representative use cases and more specialized software built around ObsPy. Additionally we will discuss new and upcoming features, as well as the sustainability of open-source scientific software.

  10. Structure-function analysis of the OB and latch domains of chlorella virus DNA ligase.

    Science.gov (United States)

    Samai, Poulami; Shuman, Stewart

    2011-06-24

    Chlorella virus DNA ligase (ChVLig) is a minimized eukaryal ATP-dependent DNA sealing enzyme with an intrinsic nick-sensing function. ChVLig consists of three structural domains, nucleotidyltransferase (NTase), OB-fold, and latch, that envelop the nicked DNA as a C-shaped protein clamp. The OB domain engages the DNA minor groove on the face of the duplex behind the nick, and it makes contacts to amino acids in the NTase domain surrounding the ligase active site. The latch module occupies the DNA major groove flanking the nick. Residues at the tip of the latch contact the NTase domain to close the ligase clamp. Here we performed a structure-guided mutational analysis of the OB and latch domains. Alanine scanning defined seven individual amino acids as essential in vivo (Lys-274, Arg-285, Phe-286, and Val-288 in the OB domain; Asn-214, Phe-215, and Tyr-217 in the latch), after which structure-activity relations were clarified by conservative substitutions. Biochemical tests of the composite nick sealing reaction and of each of the three chemical steps of the ligation pathway highlighted the importance of Arg-285 and Phe-286 in the catalysis of the DNA adenylylation and phosphodiester synthesis reactions. Phe-286 interacts with the nick 5'-phosphate nucleotide and the 3'-OH base pair and distorts the DNA helical conformation at the nick. Arg-285 is a key component of the OB-NTase interface, where it forms a salt bridge to the essential Asp-29 side chain, which is imputed to coordinate divalent metal catalysts during the nick sealing steps.

  11. Structure-Function Analysis of the OB and Latch Domains of Chlorella Virus DNA Ligase*

    Science.gov (United States)

    Samai, Poulami; Shuman, Stewart

    2011-01-01

    Chlorella virus DNA ligase (ChVLig) is a minimized eukaryal ATP-dependent DNA sealing enzyme with an intrinsic nick-sensing function. ChVLig consists of three structural domains, nucleotidyltransferase (NTase), OB-fold, and latch, that envelop the nicked DNA as a C-shaped protein clamp. The OB domain engages the DNA minor groove on the face of the duplex behind the nick, and it makes contacts to amino acids in the NTase domain surrounding the ligase active site. The latch module occupies the DNA major groove flanking the nick. Residues at the tip of the latch contact the NTase domain to close the ligase clamp. Here we performed a structure-guided mutational analysis of the OB and latch domains. Alanine scanning defined seven individual amino acids as essential in vivo (Lys-274, Arg-285, Phe-286, and Val-288 in the OB domain; Asn-214, Phe-215, and Tyr-217 in the latch), after which structure-activity relations were clarified by conservative substitutions. Biochemical tests of the composite nick sealing reaction and of each of the three chemical steps of the ligation pathway highlighted the importance of Arg-285 and Phe-286 in the catalysis of the DNA adenylylation and phosphodiester synthesis reactions. Phe-286 interacts with the nick 5′-phosphate nucleotide and the 3′-OH base pair and distorts the DNA helical conformation at the nick. Arg-285 is a key component of the OB-NTase interface, where it forms a salt bridge to the essential Asp-29 side chain, which is imputed to coordinate divalent metal catalysts during the nick sealing steps. PMID:21527793

  12. Photoionization of the diffuse interstellar medium and galactic halo by OB associtations

    Science.gov (United States)

    Dove, James B.; Shull, J. Michael

    1994-01-01

    Assuming smoothly varying H I distributions in te Galactic disk, we have calculated the geometry of diffuse II regions due to OB associations in the Galactic plane. Near the solar circle, OB associations with a Lyman continuum (Lyc) photon luminosity Psi(sub Lyc) = 3.3 x 10(exp 7) cm(exp -2) s(exp -1), produce H II regions that are density bounded in the vertical direction (H II chimneys) allowing Lyc to escape the gaseous disk and penetrate into the Galactic halo. We provide analytic formulae for the Lyc escape fraction as functions of S(sub 0) O-star catalog of Garmany and a new Lyc stellar stellar Lyc stellar flux calibration, we find a production rate of Lyc photons by OB associations within 2.5 kpc of Psi(sub Lyc) = 3.3 x 10(exp 7) cm(exp -2) s(exp -1). Integrating the fraction of Lyc photons that escape the disk over our adopted luminosity function of OB associations, we estimate that approximately 7% of the ionizing photons, or Phi(sub Lyc) = 2.3 x 10(exp 6) cm(exp -2) s(exp -1), escape each side of the H I disk layer and penetrate the diffuse ionized medium ('Reynolds layer'). This flux is sufficient to explain the potoionization of this, although we have not constructed a model for the observed H-alpha emission and pulsar dispersion measures that is fully consistent with the absorption rate of Lyc in the H II layer. Since our quiescent model does not account for the effects of dynamic chimneys and superbubbles, which should enhance Lyc escape, we conclude the O stars are the probable source of ionizing radiation for the Reynolds layer. For a random distribution of OB associations throughout the disk, the Lyc flux is nearly uniform for heights Z is greater than approximately 0.8 kpc above the midplane.

  13. ObsPy: A Python Toolbox for Seismology - Recent Developments and Applications

    Science.gov (United States)

    Megies, T.; Krischer, L.; Barsch, R.; Sales de Andrade, E.; Beyreuther, M.

    2014-12-01

    ObsPy (http://www.obspy.org) is a community-driven, open-source project dedicated to building a bridge for seismology into the scientific Python ecosystem. It offersa) read and write support for essentially all commonly used waveform, station, and event metadata file formats with a unified interface,b) a comprehensive signal processing toolbox tuned to the needs of seismologists,c) integrated access to all large data centers, web services and databases, andd) convenient wrappers to legacy codes like libtau and evalresp.Python, currently the most popular language for teaching introductory computer science courses at top-ranked U.S. departments, is a full-blown programming language with the flexibility of an interactive scripting language. Its extensive standard library and large variety of freely available high quality scientific modules cover most needs in developing scientific processing workflows. Together with packages like NumPy, SciPy, Matplotlib, IPython, Pandas, lxml, and PyQt, ObsPy enables the construction of complete workflows in Python. These vary from reading locally stored data or requesting data from one or more different data centers through to signal analysis and data processing and on to visualizations in GUI and web applications, output of modified/derived data and the creation of publication-quality figures.ObsPy enjoys a large world-wide rate of adoption in the community. Applications successfully using it include time-dependent and rotational seismology, big data processing, event relocations, and synthetic studies about attenuation kernels and full-waveform inversions to name a few examples. All functionality is extensively documented and the ObsPy tutorial and gallery give a good impression of the wide range of possible use cases.We will present the basic features of ObsPy, new developments and applications, and a roadmap for the near future and discuss the sustainability of our open-source development model.

  14. NEAR-INFRARED VARIABILITY AMONG YOUNG STELLAR OBJECTS IN THE STAR FORMATION REGION CYGNUS OB7

    Energy Technology Data Exchange (ETDEWEB)

    Wolk, Scott J.; Rice, Thomas S. [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, MA 02138 (United States); Aspin, Colin [Institute for Astronomy, University of Hawaii at Manoa, 640 North Aohoku Place, Hilo, HI 96720 (United States)

    2013-08-20

    We present an analysis of near-infrared time-series photometry in J, H, and K bands for about 100 epochs of a 1 Degree-Sign Multiplication-Sign 1 Degree-Sign region of the Lynds 1003/1004 dark cloud in the Cygnus OB7 region. Augmented by data from the Wide-field Infrared Survey Explorer, we identify 96 candidate disk bearing young stellar objects (YSOs) in the region. Of these, 30 are clearly Class I or earlier. Using the Wide-Field Imaging Camera on the United Kingdom Infrared Telescope, we were able to obtain photometry over three observing seasons, with photometric uncertainty better than 0.05 mag down to J Almost-Equal-To 17. We study detailed light curves and color trajectories of {approx}50 of the YSOs in the monitored field. We investigate the variability and periodicity of the YSOs and find the data are consistent with all YSOs being variable in these wavelengths on timescales of a few years. We divide the variability into four observational classes: (1) stars with periodic variability stable over long timescales, (2) variables which exhibit short-lived cyclic behavior, (3) long-duration variables, and (4) stochastic variables. Some YSO variability defies simple classification. We can explain much of the observed variability as being due to dynamic and rotational changes in the disk, including an asymmetric or changing blocking fraction, changes to the inner disk hole size, as well as changes to the accretion rate. Overall, we find that the Class I:Class II ratio of the cluster is consistent with an age of <1 Myr, with at least one individual, wildly varying source {approx}100, 000 yr old. We have also discovered a Class II eclipsing binary system with a period of 17.87 days.

  15. Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid

    Science.gov (United States)

    ... Physician Resources Professions Site Index A-Z Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid An ... Aspiration Biopsy of the Thyroid? What is Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid? During ...

  16. Ultrasound guided pleural biopsy in undiagnosed exudative pleural effusion patients

    Directory of Open Access Journals (Sweden)

    Adel S. Ahmed

    2016-04-01

    In conclusion: Thoracic ultrasound (TUS guided pleural biopsy had a diagnostic yield which was slightly lower but comparable to both CT guided pleural biopsy and medical thoracoscopic pleural biopsy (MT.

  17. Clinical application of Lin's biopsy grasper for intrauterine targeted biopsy and polypectomy during office hysteroscopy.

    Science.gov (United States)

    Cheng, Hsin-Yi; Lin, Bao-Liang; Tseng, Jen-Yu; Ueno, Kazunori; Nakada, Sakura

    2018-06-01

    Hysteroscopy has widely been used for diagnosis of the uterine cavity; however, target biopsy has often been difficult in part to the inherent limitations of ancillary instruments. Lin's biopsy grasper was specifically designed to work in conjunction with a flexible hysteroscope to obtain intrauterine biopsy under transabdominal sonography. Herein, we share our clinical experience in the management of endometrial abnormalities with the use of Lin's biopsy grasper during office-based hysteroscopy. From February 2006 to November 2016, the use of Lin's biopsy grasper for tissue biopsy was attempted on 126 cases. We retrospectively recorded and analyzed the patients' preoperative characteristics and biopsy outcomes to demonstrate the feasibility and efficacy of Lin's biopsy grasper. Out of the one hundred and twenty-six enrolled patients, satisfactory targeted biopsies were achieved; including high diagnostic rate (92.1%, with 116 cases confirmed histologically) and adequate tissue retrieval (77.8%, with 98 cases obtaining optimal specimen volume). All patients tolerated the procedure without analgesics or anesthesia. Diagnostic flexible hysteroscopy combined with the use of Lin's biopsy grasper has proven to be an effective tool for intrauterine evaluation and obtaining tissue sample. Copyright © 2018. Published by Elsevier B.V.

  18. CT-guided lung biopsy: incidence of pneumothorax after instillation of NaCl into the biopsy track

    Energy Technology Data Exchange (ETDEWEB)

    Billich, Christian; Brenner, Gerhard; Schmidt, Stefan A.; Brambs, Hans-Juergen; Pauls, Sandra [University of Ulm, Department of Diagnostic and Interventional Radiology, Ulm (Germany); Muche, Rainer [University of Ulm, Institute of Biometrics, Ulm (Germany); Krueger, Stefan [University of Ulm, Department of Internal Medicine, Ulm (Germany)

    2008-06-15

    This study was conducted to evaluate whether instillation of NaCl 0.9% solution into the biopsy track reduces the incidence of pneumothoraces after CT-guided lung biopsy. A total of 140 consecutive patients with pulmonary lesions were included in this prospective study. All patients were alternatingly assigned to one of two groups: group A in whom the puncture access was sealed by instillation of NaCl 0.9% solution during extraction of the guide needle (n = 70) or group B for whom no sealing was performed (n = 70). CT-guided biopsy was performed with a 18-G coaxial system. Localization of lesion (pleural, peripheral, central), lesion size, needle-pleural angle, rate of pneumothorax and alveolar hemorrhage were evaluated. In group A, the incidence of pneumothorax was lower compared to group B (8%, 6/70 patients vs. 34%, 24/70 patients; P < 0.001). All pneumothoraces occurred directly post punctionem after extraction of the guide needle. One patient in group A and eight patients in group B developed large pneumothoraces requiring chest tube placement (P = 0.01). The frequency of pneumothorax was independent of other variables. After CT-guided biopsy, instillation of NaCl 0.9% solution into the puncture access during extraction of the needle significantly reduces the incidence of pneumothorax. (orig.)

  19. CT-guided lung biopsy: incidence of pneumothorax after instillation of NaCl into the biopsy track

    International Nuclear Information System (INIS)

    Billich, Christian; Brenner, Gerhard; Schmidt, Stefan A.; Brambs, Hans-Juergen; Pauls, Sandra; Muche, Rainer; Krueger, Stefan

    2008-01-01

    This study was conducted to evaluate whether instillation of NaCl 0.9% solution into the biopsy track reduces the incidence of pneumothoraces after CT-guided lung biopsy. A total of 140 consecutive patients with pulmonary lesions were included in this prospective study. All patients were alternatingly assigned to one of two groups: group A in whom the puncture access was sealed by instillation of NaCl 0.9% solution during extraction of the guide needle (n 70) or group B for whom no sealing was performed (n = 70). CT-guided biopsy was performed with a 18-G coaxial system. Localization of lesion (pleural, peripheral, central), lesion size, needle-pleural angle, rate of pneumothorax and alveolar hemorrhage were evaluated. In group A, the incidence of pneumothorax was lower compared to group B (8%, 6/70 patients vs. 34%, 24/70 patients; P < 0.001). All pneumothoraces occurred directly post punctionem after extraction of the guide needle. One patient in group A and eight patients in group B developed large pneumothoraces requiring chest tube placement (P 0.01). The frequency of pneumothorax was independent of other variables. After CT-guided biopsy, instillation of NaCl 0.9% solution into the puncture access during extraction of the needle significantly reduces the incidence of pneumothorax. (orig.)

  20. Fluoroscopically guided automated gun biopsy of chest lesions: diagnostic accuracy and complications

    International Nuclear Information System (INIS)

    Oh, Hee Sul; Han, Young Min; Choi, Ki Chul and others

    1998-01-01

    To determine the diagnostic accuracy and frequency of complications of fluoroscopyguided transthoracic needle biopsy, using an automated gun biopsy system. We retrospectively reviewed 86 patients who underwent automated gun biopsy between October 1995 and October 1996. An 18-gauge cutting needle was used in all cases. All biopsies were performed under fluoroscopic guidance by one interventional radiologist. Tissue sufficient for histologic diagnosis was obtained in 73 of 86 biopsies(84.9%). Fifty-six lesions were malignent and 30 were benign. Sensitivity and diagnostic accuracy for malignant lesions were 87.5% and 87.5%, respectively while cell type specificity in malignant diagnosis was 91.7%(11/12). Sensitivity and diagnostic accuracy for benign lesions were 80.0% and 73.3%, respectively. Postbioptic pneumothorax occurred in three of 86 biopsies(3.5%), one of which required placement of a chest tube. Automated gun biopsy is a simple, safe method for the diagnosis of focal chest lesions. An automated biopsy device offers high diagnostic accuracy in casis involving malignant and benign lesions of the chest, and is particularly useful for determining malignant cell type and specific diagnosis of benign lesions.=20

  1. Laparoscopic splenic biopsy in dogs and cats: 15 cases (2006-2008).

    Science.gov (United States)

    Radhakrishnan, Anant; Mayhew, Philipp D

    2013-01-01

    This retrospective study describes a technique and evaluates outcome associated with laparoscopic splenic biopsy in dogs and cats. Medical records of dogs (n = 10) and cats (n = 5) that had a laparoscopic splenic biopsy performed as part of their diagnostic evaluation for systemic disease were evaluated. Splenic biopsies were performed with the patient in dorsal recumbency using a two-portal approach. In some cases, concurrent organ biopsy was also performed. A pair of 5 mm cup biopsy forceps was used for biopsy collection, and an absorbable gelatin hemostatic sponge was placed at the biopsy site to aid in hemostasis. All patients recovered without major complications. Conversion to an open surgical approach was not required. Median survival time was 180 days, and nine patients were alive at the time of manuscript preparation. Four patients were diagnosed with neoplasia; however, only one had neoplasia involving the spleen. Median survival time for the nonneoplasia group (n = 11) was 300 days. Eight of those patients were alive at time of manuscript preparation. Minimal morbidity was observed in this cohort of clinical patients. Histopathology may be preferred over cytology in some clinical situations, and laparoscopic splenic biopsy provides a minimally invasive diagnostic option.

  2. Upright stereotactic vacuum-assisted needle biopsy of suspicious breast microcalcification

    International Nuclear Information System (INIS)

    Sim, L. S. J.; Kei, P. L.

    2008-01-01

    Full text: Stereotactic core needle biopsy is a useful technique for evaluation of suspicious breast microcalcifications. Thf development of the 11-G vacuum-assisted biopsy system offers another method of minimally invasive biopsy carried out on a conventional mammography unit. We evaluate its usefulness, efficacy and safety in Asian women.. Vacuum-assisted biopsy was carried out through the lateral approach using an add-on stereotactic device attached to a mammography unit. One hundred and five lesions were sampled in 97 patients. Excisional biopsy was subsequently Carried out for diagnosis of atypical ductal hyperplasia or carcinoma in high-risk patients. Patients with benign diagnosis underwent mammographic follow up. The technical success rate was 97%. An average of 13.5 tissue cores were retrieved for each lesion. The histopathological result obtained from mammotome was benign in 84.8% and malignant in 15.2%. The benign microcalcifications were predominantly fibrocystic change (n = 42)| whereas the malignant microcalcifications included ductal carcinoma in situ (n = 15) and invasive carcinoma (n = 1). Twenty-two patients underwent subsequent open surgical biopsy but no underestimation of disease was seen. Only two patients had vasovagal syncope and three others felt unwell during the biopsy. Nine patients had small haema-1 tomas, which resolved spontaneously. Vacuum-assisted biopsy carried out on an upright stereotactic mammography] unit is a safe and effective method for evaluation of suspicious microcalcifications.

  3. Sentinel node biopsy in penile cancer

    DEFF Research Database (Denmark)

    Jakobsen, J. K.; Krarup, K. P.; Sommer, P.

    2015-01-01

    INTRODUCTION & OBJECTIVES: Nodal involvement is a strong prognosticator in penile cancer and lymph node staging is crucial. Sentinel node biopsy (SNB) has proven a useful staging tool with few complications, but evidence rely mostly on single institution publications with a short follow-up. In th......INTRODUCTION & OBJECTIVES: Nodal involvement is a strong prognosticator in penile cancer and lymph node staging is crucial. Sentinel node biopsy (SNB) has proven a useful staging tool with few complications, but evidence rely mostly on single institution publications with a short follow...... died from complications. CONCLUSIONS: To our knowledge, this is the first complete national study on sentinel node biopsy. Penile cancer sentinel node biopsy with a close follow-up is a reliable lymph node staging and has few complications in a national multicentre setting. Inguinal lymph node...

  4. Magnetic Resonance (MR)-Guided Breast Biopsy

    Science.gov (United States)

    ... over time. top of page What are the benefits vs. risks? Benefits The procedure is less invasive than surgical biopsy, ... risk of infection. The chance of infection requiring antibiotic treatment appears to be less than one in ...

  5. GoM Coastal Biopsy Surveys - NRDA

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Small vessel surveys were conducted within estuarine and nearshore coastal waters of Barataria Bay, LA and Mississippi Sound, MS to collect tissue biopsy samples...

  6. morphological pattern of endometrial biopsies in south

    African Journals Online (AJOL)

    Method: A retrospective study was undertaken to review all cases of endometrial biopsies ... MATERIALS AND METHODS. A retrospective ... tumours, 10 (0.4%) mixed tumours, 14 (0.6%) ..... accurate and concise clinical information on the.

  7. Migration of global radioactive fallout to the Arctic Ocean (on the example of the Ob's river drainage basin).

    Science.gov (United States)

    Miroshnikov, A; Semenkov, I

    2012-11-01

    This article provides an assessment of the impact of global fallout on (137)Cs contamination in the bottom sediments of Kara Sea. The erosiveness of 10th-level river basins was estimated by landscape-geochemical and geomorphological characteristics. All 10th-level basins (n=154) were separated into three groups: mountain, mountain-lowland and plain. Four different types of basins were identified depending on the geochemical conditions of the migration of radiocaesium in the plain and mountain-lowland. Classifications of types were carried out using the geographic information systems-based approach. The Ob River's macroarena covers 3.5 million km(2). Internal drainage basins cover 23 % of the macroarena and accumulate whole radiocaesium from the global fallout. The remaining territory is transitional for the (137)Cs. The field research works performed in the three plain first-level basins allow one to estimate the radiocaesium run-off. The calculations show that 7 % of (137)Cs was removed from the first-level basin in arable land. Accumulation of radiocaesium in the first-level basin under undisturbed forest is 99.8 %. The research shows that (137)Cs transfer from the humid basins is in the range of 6.9-25.5 TBq and for semi-humid basins 5.6-285.5 TBq. The areas of these basins cover 40 and 8 % of the Ob River's macroarena, respectively. Drainage lakes and reservoir drainage basins make up 22 % of the macroarena. Mountainous and semi-arid drainage basins cover 7 % of the macroarena.

  8. Outpatient percutaneous renal biopsy in adult patients

    International Nuclear Information System (INIS)

    Al-Hweish, Abdulla K.; Abdul-Rehman, I. Saeed

    2007-01-01

    To study the safety and efficacy of performing percutanaeous renal biopsy in the outpatient department compared to the traditional inpatient policy, we studied 44 consecutive patients with proteinuria and other urinary sediment abnormalities, at King Fahd Hospital of the University, Al-Khobar, Saudi Arabia, during the period from September 2004 to August 2006. The patients were divided into two groups: group I, in whom kidney biopsy was performed and followed by 1-day hospital admission; and group II, in whom renal biopsy was performed in the outpatient department and followed by 6 hours observation period and then by regular outpatient visits. All biopsies were performed with the use of real-time ultrasound and automated biopsy needle. Patients with a history of bleeding diathesis or abnormal coagulation profile and those receiving warfarin, heparin, aspirin or nonsteroidal anti-inflammatory drugs were excluded from the study. Only minor biopsy-related complications such as gross hematuria, perinephric hematoma that resolved without the need for blood transfusion or surgical intervention occurred in three (13.6%) patients in group I and in two (9.1%) patients in group II. The complications were apparent within 6 hours in all but one patient (97.7%). Overall, hematuria was identified in 52% of patients at <-72 hours, 85% at <-4 hours and 97.7% at <- 6 hours. The 24-hour hematocrit levels were not significantly different between the study groups. One (4.5%) patient from group II had a small perinephric hematoma, which was detected by ultrasound examination at 24 hours but not at 6 hours post biopsy period; it resolved spontaneously without intervention. We conclude that in selected patients, same day discharge after 6 hours of renal biopsy may be given safety without increased risk of complications. (author)

  9. PET/CT-guided biopsies of metabolically active bone lesions: applications and clinical impact

    Energy Technology Data Exchange (ETDEWEB)

    Klaeser, Bernd; Wartenberg, Jan; Weitzel, Thilo; Krause, Thomas [Bern University Hospital and University of Bern, Department of Nuclear Medicine, Inselspital, Bern (Switzerland); Wiskirchen, Jakub [Bern University Hospital and University of Bern, Department of Nuclear Medicine, Inselspital, Bern (Switzerland); University Hospital Tuebingen, Department of Radiology, Neuroradiology, and Nuclear Medicine, Tuebingen (Germany); Schmid, Ralph A. [Bern University Hospital and University of Bern, Department of Thoracic Surgery, Inselspital, Bern (Switzerland); Mueller, Michel D. [Bern University Hospital and University of Bern, Department of Obstetrics and Gynaecology, Inselspital, Bern (Switzerland)

    2010-11-15

    In a minority of cases a definite diagnosis and stage grouping in cancer patients is not possible based on the imaging information of PET/CT. We report our experience with percutaneous PET/CT-guided bone biopsies to histologically verify the aetiology of hypermetabolic bone lesions. We retrospectively reviewed the data of 20 consecutive patients who underwent multimodal image-guided bone biopsies using a dedicated PET/CT system in a step-by-step technique. Technical and clinical success rates of PET/CT-guided biopsies were evaluated. Questionnaires were sent to the referring physicians to assess the impact of biopsies on patient management and to check the clinical need for PET/CT-guided biopsies. Clinical indications for biopsy were to histologically verify the aetiology of metabolically active bone lesions without a morphological correlate confirming the suspicion of metastases in 15 patients, to determine the origin of suspected metastases in 3 patients and to evaluate the appropriateness of targeted therapy options in 2 patients. Biopsies were technically successful in all patients. In 19 of 20 patients a definite histological diagnosis was possible. No complications or adverse effects occurred. The result of PET/CT-guided bone biopsies determined a change of the planned treatment in overall 56% of patients, with intramodality changes, e.g. chemotherapy with palliative instead of curative intent, and intermodality changes, e.g. systemic therapy instead of surgery, in 22 and 50%, respectively. PET/CT-guided bone biopsies are a promising alternative to conventional techniques to make metabolically active bone lesions - especially without a distinctive morphological correlate - accessible for histological verification. PET/CT-guided biopsies had a major clinical impact in patients who otherwise cannot be reliably stage grouped at the time of treatment decisions. (orig.)

  10. Ultrasound-guided percutaneous renal biopsy with an automated biopsy gun in diffuse renal disease

    International Nuclear Information System (INIS)

    Kim, Ji Yang; Moon, Jeoung Mi; Park, Ji Hyun; Kwon, Jae Soo; Song, Ik Hoon; Kim, Sung Rok

    1994-01-01

    We evaluated the effectiveness and clinical usefulness of percutaneous renal biopsy by using automated biopsy gun under the real-time ultrasonographic guidance that was performed in 17 patients with diffuse renal disease. We retrospectively analysed the histopathological diagnosis and the patients' status after percutaneous renal biopsy.Adequate amount of tissue for the histologic diagnosis could be obtained in al patients. Histopathologic diagnosis included the minimal change nephrotic syndrome in 6 patients, the membrano proliferative glomerulonephritis in 4,the membranous glomerulonephritis in 2, the glomerulosclerosis in 2, Ig A nephropathy in 2, and the normal finding in 1. Significant complication occurred in only one patient who developed a transient loss of sensation at and around the biopsy site. In conclusion, automated biopsy gun was a very useful device in performing percutaneous biopsy for diffuse renal disease with a high success rate and a low complication rate

  11. OBS Data Denoising Based on Compressed Sensing Using Fast Discrete Curvelet Transform

    Science.gov (United States)

    Nan, F.; Xu, Y.

    2017-12-01

    OBS (Ocean Bottom Seismometer) data denoising is an important step of OBS data processing and inversion. It is necessary to get clearer seismic phases for further velocity structure analysis. Traditional methods for OBS data denoising include band-pass filter, Wiener filter and deconvolution etc. (Liu, 2015). Most of these filtering methods are based on Fourier Transform (FT). Recently, the multi-scale transform methods such as wavelet transform (WT) and Curvelet transform (CvT) are widely used for data denoising in various applications. The FT, WT and CvT could represent signal sparsely and separate noise in transform domain. They could be used in different cases. Compared with Curvelet transform, the FT has Gibbs phenomenon and it cannot handle points discontinuities well. WT is well localized and multi scale, but it has poor orientation selectivity and could not handle curves discontinuities well. CvT is a multiscale directional transform that could represent curves with only a small number of coefficients. It provide an optimal sparse representation of objects with singularities along smooth curves, which is suitable for seismic data processing. As we know, different seismic phases in OBS data are showed as discontinuous curves in time domain. Hence, we promote to analysis the OBS data via CvT and separate the noise in CvT domain. In this paper, our sparsity-promoting inversion approach is restrained by L1 condition and we solve this L1 problem by using modified iteration thresholding. Results show that the proposed method could suppress the noise well and give sparse results in Curvelet domain. Figure 1 compares the Curvelet denoising method with Wavelet method on the same iterations and threshold through synthetic example. a)Original data. b) Add-noise data. c) Denoised data using CvT. d) Denoised data using WT. The CvT can well eliminate the noise and has better result than WT. Further we applied the CvT denoise method for the OBS data processing. Figure 2a

  12. Liver Biopsies for Chronic Hepatitis C: Should Nonultrasound-Guided Biopsies Be Abandoned?

    Directory of Open Access Journals (Sweden)

    Jennifer A Flemming

    2009-01-01

    Full Text Available BACKGROUND/OBJECTIVE: Liver biopsy has been the gold standard for grading and staging chronic hepatitis C virus (HCV-mediated liver injury. Traditionally, this has been performed by trained practitioners using a nonimage-guided percutaneous technique at the bedside. Recent literature suggests an expanding role for radiologists in obtaining biopsies using an ultrasound (US-guided technique. The present study was undertaken study to determine if the two techniques produced liver biopsy specimens of similar quality and hypothesized that at our institution, non-US-guided percutaneous liver biopsies for HCV would be of higher quality than US-guided specimens.

  13. Electronic Commerce -RE-SONANCE---IOct-ob-er

    Indian Academy of Sciences (India)

    and the emergence of a number of Internet Service Providers. (lSPs) who ..... may be a distributed client/server type system with each office being a client and the .... called denial of service in which a large number of frivolous enquiries are ...

  14. Multifunctional Bi2ZnOB2O6 single crystals for second and third order nonlinear optical applications

    International Nuclear Information System (INIS)

    Iliopoulos, K.; Kasprowicz, D.; Majchrowski, A.; Michalski, E.; Gindre, D.; Sahraoui, B.

    2013-01-01

    Bi 2 ZnOB 2 O 6 nonlinear optical single crystals were grown by means of the Kyropoulos method from stoichiometric melt. The second and third harmonic generation (SHG/THG) of Bi 2 ZnOB 2 O 6 crystals were investigated by the SHG/THG Maker fringes technique. Moreover, SHG microscopy studies were carried out providing two-dimensional SHG images as a function of the incident laser polarization. The high nonlinear optical efficiency combined with the possibility to grow high quality crystals make Bi 2 ZnOB 2 O 6 an excellent candidate for photonic applications

  15. Marked augmentation of PLGA nanoparticle-induced metabolically beneficial impact of γ-oryzanol on fuel dyshomeostasis in genetically obese-diabetic ob/ob mice.

    Science.gov (United States)

    Kozuka, Chisayo; Shimizu-Okabe, Chigusa; Takayama, Chitoshi; Nakano, Kaku; Morinaga, Hidetaka; Kinjo, Ayano; Fukuda, Kotaro; Kamei, Asuka; Yasuoka, Akihito; Kondo, Takashi; Abe, Keiko; Egashira, Kensuke; Masuzaki, Hiroaki

    2017-11-01

    Our previous works demonstrated that brown rice-specific bioactive substance, γ-oryzanol acts as a chaperone, attenuates exaggerated endoplasmic reticulum (ER) stress in brain hypothalamus and pancreatic islets, thereby ameliorating metabolic derangement in high fat diet (HFD)-induced obese diabetic mice. However, extremely low absorption efficiency from intestine of γ-oryzanol is a tough obstacle for the clinical application. Therefore, in this study, to overcome extremely low bioavailability of γ-oryzanol with super-high lipophilicity, we encapsulated γ-oryzanol in polymer poly (DL-lactide-co-glycolide) (PLGA) nanoparticles (Nano-Orz), and evaluated its metabolically beneficial impact in genetically obese-diabetic ob/ob mice, the best-known severest diabetic model in mice. To our surprise, Nano-Orz markedly ameliorated fuel metabolism with an unexpected magnitude (∼1000-fold lower dose) compared with regular γ-oryzanol. Furthermore, such a conspicuous impact was achievable by its administration once every 2 weeks. Besides the excellent impact on dysfunction of hypothalamus and pancreatic islets, Nano-Orz markedly decreased ER stress and inflammation in liver and adipose tissue. Collectively, nanotechnology-based developments of functional foods oriented toward γ-oryzanol shed light on the novel approach for the treatment of a variety of metabolic diseases in humans.

  16. Optimization of the Static Human Osteoblast/Osteoclast Co-culture System

    Directory of Open Access Journals (Sweden)

    James Jam Jolly

    2018-03-01

    Full Text Available Osteoblasts (OBs and osteoclasts (OCs are 2 major groups of bone cells. Their cell-to-cell interactions are important to ensure the continuity of the bone-remodeling process. Therefore, the present study was carried out to optimize an OB/OC co-culture system utilizing the human OB cell line hFOB 1.19 and OCs extracted from peripheral blood mononuclear cells (PBMNCs. It was a 2-step procedure, involving the optimization of the OB culture and the co-culture of the OBs with PBMNCs at an optimum ratio. Firstly, pre-OBs were cultured to 90% confluency and the time required for differentiation was determined. OB differentiation was determined using the van Gieson staining to detect the presence of collagen and Alizarin Red for calcium. Secondly, OBs and OCs were co-cultured at the ratios of 1 OC: 1 OB, 1 OC: 4 OBs, 2 OCs: 1 OB, and 1 OC: 2 OBs. Tartrate-resistant acid phosphatase (TRAP staining was used to detect the differentiation of the OCs. The results showed that collagen was present on day 1, whereas calcium was detected as early as day 3. Based on the result of TRAP staining, 1 OC: 2 OBs was taken as the most appropriate ratio. No macrophage colony-stimulating factor and receptor activator of the nuclear factor-κB ligand were added because they were provided by the OBs. In conclusion, these optimization processes are vital as they ensure the exact time point and ratio of the OB/OC co-culture in order to produce a reliable and reproducible co-culture system.

  17. Ultrasound-guided diagnostic breast biopsy methodology: retrospective comparison of the 8-gauge vacuum-assisted biopsy approach versus the spring-loaded 14-gauge core biopsy approach

    Science.gov (United States)

    2011-01-01

    Background Ultrasound-guided diagnostic breast biopsy technology represents the current standard of care for the evaluation of indeterminate and suspicious lesions seen on diagnostic breast ultrasound. Yet, there remains much debate as to which particular method of ultrasound-guided diagnostic breast biopsy provides the most accurate and optimal diagnostic information. The aim of the current study was to compare and contrast the 8-gauge vacuum-assisted biopsy approach and the spring-loaded 14-gauge core biopsy approach. Methods A retrospective analysis was done of all ultrasound-guided diagnostic breast biopsy procedures performed by either the 8-gauge vacuum-assisted biopsy approach or the spring-loaded 14-gauge core biopsy approach by a single surgeon from July 2001 through June 2009. Results Among 1443 ultrasound-guided diagnostic breast biopsy procedures performed, 724 (50.2%) were by the 8-gauge vacuum-assisted biopsy technique and 719 (49.8%) were by the spring-loaded 14-gauge core biopsy technique. The total number of false negative cases (i.e., benign findings instead of invasive breast carcinoma) was significantly greater (P = 0.008) in the spring-loaded 14-gauge core biopsy group (8/681, 1.2%) as compared to in the 8-gauge vacuum-assisted biopsy group (0/652, 0%), with an overall false negative rate of 2.1% (8/386) for the spring-loaded 14-gauge core biopsy group as compared to 0% (0/148) for the 8-gauge vacuum-assisted biopsy group. Significantly more (P guided diagnostic breast biopsy procedure. Significantly more (P guided diagnostic breast biopsy procedure. Conclusions In appropriately selected cases, the 8-gauge vacuum-assisted biopsy approach appears to be advantageous to the spring-loaded 14-gauge core biopsy approach for providing the most accurate and optimal diagnostic information. PMID:21835024

  18. Further RIOTS4 Characterization of Field OB Stars in the SMC

    Science.gov (United States)

    Oey, M. S.; Barnes, Jesse R.; Paggeot, Kevin J.; Dorigo Jones, John; Castro, Norberto; Simon-Diaz, Sergio; Kratter, Kaitlin M.; Moe, Maxwell; Szymanski, Michal

    2018-06-01

    We present recent results from the Runaways and O-Type Star Spectroscopic Survey of the SMC (RIOTS4), a survey quantifying properties of the field OB stars in the Small Magellanic Cloud (SMC). Based on PSF-fitting photometry and astrometry of OGLE-III I-band images, we quantify the degree of isolation for the target OB stars, classifying them as "tip-of-the-iceberg" stars accompanied by small, sparse, clusters; or as true, isolated field stars. Many of these field stars must be runaways, which we evaluate using GAIA DR2 proper motions. We measure v sin i using the IACOB code Fourier analysis, finding that the bimodal distribution of projected rotation velocities is less pronounced for O stars than early B stars. We examine rotation in relation to relative isolation and runaway status.

  19. BOREAS TF-3 Automated Chamber CO2 Flux Data from the NSA-OBS

    Science.gov (United States)

    Goulden, Michael L.; Crill, Patrick M.; Hall, Forrest G. (Editor); Conrad, Sara (Editor)

    2000-01-01

    The BOReal Ecosystem Atmosphere Study Tower Flux (BOREAS TF-3) and Trace Gas Biogeochemistry (TGB-1) teams collected automated CO2 chamber flux data in their efforts to fully describe the CO2 flux at the Northern Study Area-Old Black Spruce (NSA-OBS) site. This data set contains fluxes of CO2 at the NSA-OBS site measured using automated chambers. In addition to reporting the CO2 flux, it reports chamber air temperature, moss temperature, and light levels during each measurement. The data set covers the period from 23-Sep-1995 through 26-Oct-1995 and from 28-May-1996 through 21-Oct-1996. The data are stored in tabular ASCII files.

  20. Conversion of chlorinated propanes by Methylosinus trichosporium OB3b expressing soluble methane monooxygenase

    OpenAIRE

    Bosma, T.; Janssen, D.B.

    1998-01-01

    Chlorinated propanes are important pollutants that may show persistent behaviour in the environment. The biotransformation of 1-chloropropane, 1,2-dichloropropane, 1,3-dichloropropane and 1,2,3-trichloropropane was studied using resting cell suspensions of Methylosinus trichosporium OB3b expressing soluble methane monooxygenase. The transformation followed first-order kinetics. The rate constants were in the order 1-chloropropane > 1,3-dichloropropane > 1,2-dichloropropane > 1,2,3-trichloropr...

  1. ObStruct: a method to objectively analyse factors driving population structure using Bayesian ancestry profiles.

    Directory of Open Access Journals (Sweden)

    Velimir Gayevskiy

    Full Text Available Bayesian inference methods are extensively used to detect the presence of population structure given genetic data. The primary output of software implementing these methods are ancestry profiles of sampled individuals. While these profiles robustly partition the data into subgroups, currently there is no objective method to determine whether the fixed factor of interest (e.g. geographic origin correlates with inferred subgroups or not, and if so, which populations are driving this correlation. We present ObStruct, a novel tool to objectively analyse the nature of structure revealed in Bayesian ancestry profiles using established statistical methods. ObStruct evaluates the extent of structural similarity between sampled and inferred populations, tests the significance of population differentiation, provides information on the contribution of sampled and inferred populations to the observed structure and crucially determines whether the predetermined factor of interest correlates with inferred population structure. Analyses of simulated and experimental data highlight ObStruct's ability to objectively assess the nature of structure in populations. We show the method is capable of capturing an increase in the level of structure with increasing time since divergence between simulated populations. Further, we applied the method to a highly structured dataset of 1,484 humans from seven continents and a less structured dataset of 179 Saccharomyces cerevisiae from three regions in New Zealand. Our results show that ObStruct provides an objective metric to classify the degree, drivers and significance of inferred structure, as well as providing novel insights into the relationships between sampled populations, and adds a final step to the pipeline for population structure analyses.

  2. Obésité abdominale et autres biomarqueurs de risque ...

    African Journals Online (AJOL)

    Obésité abdominale et autres biomarqueurs de risque cardiométabolique: influence du niveau socioéconomique et du mode de vie dans deux populations noires apparentées, Cotonou (Bénin) et Port-au-Prince (Haïti). Asma EL Mabchour, Hélène Delisle, Colette Vilgrain, Phillipe Larco, Roger Sodjinou ...

  3. Bioinformatics analysis identify novel OB fold protein coding genes in C. elegans.

    Directory of Open Access Journals (Sweden)

    Daryanaz Dargahi

    Full Text Available BACKGROUND: The C. elegans genome has been extensively annotated by the WormBase consortium that uses state of the art bioinformatics pipelines, functional genomics and manual curation approaches. As a result, the identification of novel genes in silico in this model organism is becoming more challenging requiring new approaches. The Oligonucleotide-oligosaccharide binding (OB fold is a highly divergent protein family, in which protein sequences, in spite of having the same fold, share very little sequence identity (5-25%. Therefore, evidence from sequence-based annotation may not be sufficient to identify all the members of this family. In C. elegans, the number of OB-fold proteins reported is remarkably low (n=46 compared to other evolutionary-related eukaryotes, such as yeast S. cerevisiae (n=344 or fruit fly D. melanogaster (n=84. Gene loss during evolution or differences in the level of annotation for this protein family, may explain these discrepancies. METHODOLOGY/PRINCIPAL FINDINGS: This study examines the possibility that novel OB-fold coding genes exist in the worm. We developed a bioinformatics approach that uses the most sensitive sequence-sequence, sequence-profile and profile-profile similarity search methods followed by 3D-structure prediction as a filtering step to eliminate false positive candidate sequences. We have predicted 18 coding genes containing the OB-fold that have remarkably partially been characterized in C. elegans. CONCLUSIONS/SIGNIFICANCE: This study raises the possibility that the annotation of highly divergent protein fold families can be improved in C. elegans. Similar strategies could be implemented for large scale analysis by the WormBase consortium when novel versions of the genome sequence of C. elegans, or other evolutionary related species are being released. This approach is of general interest to the scientific community since it can be used to annotate any genome.

  4. Diacylglycerol production induced by growth hormone in Ob1771 preadipocytes arises from phosphatidylcholine breakdown

    International Nuclear Information System (INIS)

    Catalioto, R.M.; Ailhaud, G.; Negrel, R.

    1990-01-01

    Growth Hormone has recently been shown to stimulate the formation of diacylglycerol in Ob1771 mouse preadipocyte cells without increasing inositol lipid turnover. Addition of growth hormone to Ob1771 cells prelabelled with [ 3 H]glycerol or [ 3 H]choline led to a rapid, transient and stoechiometric formation of labelled diacylglycerol and phosphocholine, respectively. In contrast, no change was observed in the level of choline and phosphatidic acid whereas the release of water-soluble metabolites in [ 3 H]ethanolamine prelabelled cells exposed to growth hormone was hardly detectable. Stimulation by growth hormone of cells prelabelled with (2-palmitoyl 9, 10 [ 3 H])phosphatidylcholine also induced the production of labelled diacyglycerol. Pertussis toxin abolished both diacylglycerol and phosphocholine formation induced by growth hormone. It is concluded that growth hormone mediates diacylglycerol production in Ob1771 cells by means of phosphatidylcholine breakdown involving a phospholipase C which is likely coupled to the growth hormone receptor via a pertussis toxin-sensitive G-protein

  5. Relative Stabilities of Conserved and Non-Conserved Structures in the OB-Fold Superfamily

    Directory of Open Access Journals (Sweden)

    Andrei T. Alexandrescu

    2009-05-01

    Full Text Available The OB-fold is a diverse structure superfamily based on a β-barrel motif that is often supplemented with additional non-conserved secondary structures. Previous deletion mutagenesis and NMR hydrogen exchange studies of three OB-fold proteins showed that the structural stabilities of sites within the conserved β-barrels were larger than sites in non-conserved segments. In this work we examined a database of 80 representative domain structures currently classified as OB-folds, to establish the basis of this effect. Residue-specific values were obtained for the number of Cα-Cα distance contacts, sequence hydrophobicities, crystallographic B-factors, and theoretical B-factors calculated from a Gaussian Network Model. All four parameters point to a larger average flexibility for the non-conserved structures compared to the conserved β-barrels. The theoretical B-factors and contact densities show the highest sensitivity.Our results suggest a model of protein structure evolution in which novel structural features develop at the periphery of conserved motifs. Core residues are more resistant to structural changes during evolution since their substitution would disrupt a larger number of interactions. Similar factors are likely to account for the differences in stability to unfolding between conserved and non-conserved structures.

  6. Improvements to the gridding of precipitation data across Europe under the E-OBS scheme

    Science.gov (United States)

    Cornes, Richard; van den Besselaar, Else; Jones, Phil; van der Schrier, Gerard; Verver, Ge

    2016-04-01

    Gridded precipitation data are a valuable resource for analyzing past variations and trends in the hydroclimate. Such data also provide a reference against which model simulations may be driven, compared and/or adjusted. The E-OBS precipitation dataset is widely used for such analyses across Europe, and is particularly valuable since it provides a spatially complete, daily field across the European domain. In this analysis, improvements to the E-OBS precipitation dataset will be presented that aim to provide a more reliable estimate of grid-box precipitation values, particularly in mountainous areas and in regions with a relative sparsity of input station data. The established three-stage E-OBS gridding scheme is retained, whereby monthly precipitation totals are gridded using a thin-plate spline; daily anomalies are gridded using indicator kriging; and the final dataset is produced by multiplying the two grids. The current analysis focuses on improving the monthly thin-plate spline, which has overall control on the final daily dataset. The results from different techniques are compared and the influence on the final daily data is assessed by comparing the data against gridded country-wide datasets produced by various National Meteorological Services

  7. A model for the infrared emission from an OB star cluster environment

    International Nuclear Information System (INIS)

    Leisawitz, D.

    1990-01-01

    Researchers developed an interactive radiative transfer code that predicts the infrared emission from an HII region containing diffuse ionized and atomic gas and dense molecular clouds. This model complements the investigation of the redistribution of OB star luminosity in the interstellar medium (Leisawitz and Hauser 1988, Ap. J., 332, 954). The model can be used as a diagnostic tool to probe the radiation field and matter density in an HII region, place constraints on the proximity and orientation of an illuminated molecular cloud with respect to the ionizing stars, test for the presence of small, transiently heated dust grains, and determine whether the dust-to-gas ratio is normal. Predictions of the model agree qualitatively and quantitatively with observations of blister-type HII regions ionized by well-studied OB clusters in which the distribution of dense neutral material is known. This is illustrated by a model for Infrared Astronomy Satellite (IRAS) observations of the region around NGC 7380 (S142). Researchers plan to use the model in a survey of regions of massive star formation in the outer Galaxy to study OB stars embedded to various degrees in their parental molecular clouds

  8. Diacylglycerol production induced by growth hormone in Ob1771 preadipocytes arises from phosphatidylcholine breakdown

    Energy Technology Data Exchange (ETDEWEB)

    Catalioto, R.M.; Ailhaud, G.; Negrel, R. (Universite de Nice-Sophia Antipolis (France))

    1990-12-31

    Growth Hormone has recently been shown to stimulate the formation of diacylglycerol in Ob1771 mouse preadipocyte cells without increasing inositol lipid turnover. Addition of growth hormone to Ob1771 cells prelabelled with ({sup 3}H)glycerol or ({sup 3}H)choline led to a rapid, transient and stoechiometric formation of labelled diacylglycerol and phosphocholine, respectively. In contrast, no change was observed in the level of choline and phosphatidic acid whereas the release of water-soluble metabolites in ({sup 3}H)ethanolamine prelabelled cells exposed to growth hormone was hardly detectable. Stimulation by growth hormone of cells prelabelled with (2-palmitoyl 9, 10 ({sup 3}H))phosphatidylcholine also induced the production of labelled diacyglycerol. Pertussis toxin abolished both diacylglycerol and phosphocholine formation induced by growth hormone. It is concluded that growth hormone mediates diacylglycerol production in Ob1771 cells by means of phosphatidylcholine breakdown involving a phospholipase C which is likely coupled to the growth hormone receptor via a pertussis toxin-sensitive G-protein.

  9. Fluoroscopy-Guided Percutaneous Vertebral Body Biopsy Using a Novel Drill-Powered Device: Technical Case Series

    International Nuclear Information System (INIS)

    Wallace, Adam N.; Pacheco, Rafael A.; Tomasian, Anderanik; Hsi, Andy C.; Long, Jeremiah; Chang, Randy O.; Jennings, Jack W.

    2016-01-01

    BackgroundA novel coaxial biopsy system powered by a handheld drill has recently been introduced for percutaneous bone biopsy. This technical note describes our initial experience performing fluoroscopy-guided vertebral body biopsies with this system, compares the yield of drill-assisted biopsy specimens with those obtained using a manual technique, and assesses the histologic adequacy of specimens obtained with drill assistance.MethodsMedical records of all single-level, fluoroscopy-guided vertebral body biopsies were reviewed. Procedural complications were documented according to the Society of Interventional Radiology classification. The total length of bone core obtained from drill-assisted biopsies was compared with that of matched manual biopsies. Pathology reports were reviewed to determine the histologic adequacy of specimens obtained with drill assistance.ResultsTwenty eight drill-assisted percutaneous vertebral body biopsies met study inclusion criteria. No acute complications were reported. Of the 86 % (24/28) of patients with clinical follow-up, no delayed complications were reported (median follow-up, 28 weeks; range 5–115 weeks). The median total length of bone core obtained from drill-assisted biopsies was 28 mm (range 8–120 mm). This was longer than that obtained from manual biopsies (median, 20 mm; range 5–45 mm; P = 0.03). Crush artifact was present in 11 % (3/28) of drill-assisted biopsy specimens, which in one case (3.6 %; 1/28) precluded definitive diagnosis.ConclusionsA drill-assisted, coaxial biopsy system can be used to safely obtain vertebral body core specimens under fluoroscopic guidance. The higher bone core yield obtained with drill assistance may be offset by the presence of crush artifact

  10. Fluoroscopy-Guided Percutaneous Vertebral Body Biopsy Using a Novel Drill-Powered Device: Technical Case Series

    Energy Technology Data Exchange (ETDEWEB)

    Wallace, Adam N., E-mail: wallacea@mir.wustl.edu; Pacheco, Rafael A., E-mail: pachecor@mir.wustl.edu; Tomasian, Anderanik, E-mail: tomasiana@mir.wustl.edu [Washington University School of Medicine, Mallinckrodt Institute of Radiology (United States); Hsi, Andy C., E-mail: hsia@path.wustl.edu [Washington University School of Medicine, Division of Anatomic Pathology, Department of Pathology & Immunology (United States); Long, Jeremiah, E-mail: longj@mir.wustl.edu [Washington University School of Medicine, Mallinckrodt Institute of Radiology (United States); Chang, Randy O., E-mail: changr@wusm.wustl.edu [Washington University School of Medicine (United States); Jennings, Jack W., E-mail: jenningsj@mir.wustl.edu [Washington University School of Medicine, Mallinckrodt Institute of Radiology (United States)

    2016-02-15

    BackgroundA novel coaxial biopsy system powered by a handheld drill has recently been introduced for percutaneous bone biopsy. This technical note describes our initial experience performing fluoroscopy-guided vertebral body biopsies with this system, compares the yield of drill-assisted biopsy specimens with those obtained using a manual technique, and assesses the histologic adequacy of specimens obtained with drill assistance.MethodsMedical records of all single-level, fluoroscopy-guided vertebral body biopsies were reviewed. Procedural complications were documented according to the Society of Interventional Radiology classification. The total length of bone core obtained from drill-assisted biopsies was compared with that of matched manual biopsies. Pathology reports were reviewed to determine the histologic adequacy of specimens obtained with drill assistance.ResultsTwenty eight drill-assisted percutaneous vertebral body biopsies met study inclusion criteria. No acute complications were reported. Of the 86 % (24/28) of patients with clinical follow-up, no delayed complications were reported (median follow-up, 28 weeks; range 5–115 weeks). The median total length of bone core obtained from drill-assisted biopsies was 28 mm (range 8–120 mm). This was longer than that obtained from manual biopsies (median, 20 mm; range 5–45 mm; P = 0.03). Crush artifact was present in 11 % (3/28) of drill-assisted biopsy specimens, which in one case (3.6 %; 1/28) precluded definitive diagnosis.ConclusionsA drill-assisted, coaxial biopsy system can be used to safely obtain vertebral body core specimens under fluoroscopic guidance. The higher bone core yield obtained with drill assistance may be offset by the presence of crush artifact.

  11. Initial experience with new dedicated needles for laparoscopic ultrasound-guided fine-needle aspiration and histological biopsies

    DEFF Research Database (Denmark)

    Mortensen, M B; Durup, J; Pless, T

    2001-01-01

    BACKGROUND AND STUDY AIMS: Laparoscopic ultrasonography (LUS) is an important imaging modality during laparoscopic staging of intra-abdominal malignancies, but LUS-assisted biopsy is often difficult or impossible. We report a newly developed inbuilt biopsy system for direct LUS-guided fine......-needle aspiration (FNA) and Tru-cut biopsies. PATIENTS AND METHODS: LUS-guided biopsy was performed in 20 patients with upper gastrointestinal tract tumors. The biopsied lesions had either not been previously detected by other imaging modalities or had been inaccessible, or the biopsy sample had been inadequate...... were good or acceptable in 18 patients (90%). Slight needle deviation (material was obtained, but pathological examination was impossible owing...

  12. Oral biopsy: Oral pathologist′s perspective

    Directory of Open Access Journals (Sweden)

    K L Kumaraswamy

    2012-01-01

    Full Text Available Many oral lesions may need to be diagnosed by removing a sample of tissue from the oral cavity. Biopsy is widely used in the medical field, but the practice is not quite widespread in dental practice. As oral pathologists, we have found many artifacts in the tissue specimen because of poor biopsy technique or handling, which has led to diagnostic pitfalls and misery to both the patient and the clinician. This article aims at alerting the clinicians about the clinical faults arising preoperatively, intraoperatively and postoperatively while dealing with oral biopsy that may affect the histological assessment of the tissue and, therefore, the diagnosis. It also reviews the different techniques, precautions and special considerations necessary for specific lesions.

  13. Isolate pulmonary nodule. CT-guided biopsy

    International Nuclear Information System (INIS)

    Bruneton, J.N.; Ettore, F.; Rogopoulos, A.; Geoffray, A.; Balu-Maestro, C.; Le Houcq, M.

    1989-01-01

    Transparietal CT-guided biopsy location can be successfully performed for isolate pulmonary nodules, defined as lesions with a maximal diameter of 3 cm, without any other parenchymal or mediastinal abnormality. A 21 G needle has been used according to an identical protocole in 64 cases (10 benign, 54 malignant). The biopsy was successful in 77.7% of the malignant cases. In relation to the diameter of the nodules, biopsy was successful in 66.7% of the nodules smaller than 2 cm and in 76% of the nodules ranging from 2 to 3 cm. The complications observed were rare (1 case of pneumothorax requiring drainage, 9 cases of pneumothorax without clinical signs and simply followed up, 4 cases of minor hemoptysis requiring no treatment and 5 cases of hematomas smaller than 5 cm on CT) [fr

  14. Comparative study of decomposable and indecomposable biopsy needle in lung puncture biopsy

    International Nuclear Information System (INIS)

    Wang Bo; Sheng Zhanxin; Wen Yamin; Zhang Liping; Wen Zongqiu

    2007-01-01

    Objective: To contrast the clinical practice characteristics with decomposable and indecomposable biopsy needle in the CT-guided lung puncture biopsy. Methods: 50 patients with lung tumour carried on puncture biopsy under the CT guidance were divided in two groups randomly: Group A (25 examples): using the indecomposable BioPinceTM biopsy needle; Group B(25 examples): using the decomposable Precisa or Vitesse biopsy needle. The puncture biopsy organization quantity, the first time puncture success rate, the pathological diagnosis result and the incidence of puncture complication were compared in two groups. Results: More striped structures were gained obviously in group A than in group B: 24/25 and 11/25 respectively (P>0.05), The pathological diagnosis 'serious extrusion amoebocyte and nature undetermined' only occurred in group B. But the first time puncture success rate was lower in group A than in B: 52%(13/25) and 80%(20/25) respectively (P>0.05), The incidence of hemorrhage and pneumothorax in group A was higher slightly: 84% and 72%, 16% and 4% respectively (P>0.05). Conclusion: The indecomposable needle (BioPinceTM) was better in lung puncture biopsy, but the lower first time puncture success rate also increases the risk of operation and complication in some degree because of the structure of the needle. On the contrary, decomposable needle (the Precisa or the Vitesse) was not the best choice in lung puncture biopsy. But it had the original superiority, especially regarding the special patient such as patient with small tumour, thin thoracic wall, bad physique for its nimble operation. It is essential for us to use the two different types of biopsy needle rationally to enhance the level of CT-guided lung puncture biopsy. (authors)

  15. Navigated MRI-guided liver biopsies in a closed-bore scanner: experience in 52 patients.

    Science.gov (United States)

    Moche, Michael; Heinig, Susann; Garnov, Nikita; Fuchs, Jochen; Petersen, Tim-Ole; Seider, Daniel; Brandmaier, Philipp; Kahn, Thomas; Busse, Harald

    2016-08-01

    To evaluate clinical effectiveness and diagnostic efficiency of a navigation device for MR-guided biopsies of focal liver lesions in a closed-bore scanner. In 52 patients, 55 biopsies were performed. An add-on MR navigation system with optical instrument tracking was used for image guidance and biopsy device insertion outside the bore. Fast control imaging allowed visualization of the true needle position at any time. The biopsy workflow and procedure duration were recorded. Histological analysis and clinical course/outcome were used to calculate sensitivity, specificity and diagnostic accuracy. Fifty-four of 55 liver biopsies were performed successfully with the system. No major and four minor complications occurred. Mean tumour size was 23 ± 14 mm and the skin-to-target length ranged from 22 to 177 mm. In 39 cases, access path was double oblique. Sensitivity, specificity and diagnostic accuracy were 88 %, 100 % and 92 %, respectively. The mean procedure time was 51 ± 12 min, whereas the puncture itself lasted 16 ± 6 min. On average, four control scans were taken. Using this navigation device, biopsies of poorly visible and difficult accessible liver lesions could be performed safely and reliably in a closed-bore MRI scanner. The system can be easily implemented in clinical routine workflow. • Targeted liver biopsies could be reliably performed in a closed-bore MRI. • The navigation system allows for image guidance outside of the scanner bore. • Assisted MRI-guided biopsies are helpful for focal lesions with a difficult access. • Successful integration of the method in clinical workflow was shown. • Subsequent system installation in an existing MRI environment is feasible.

  16. A M2FS Spectroscopic Study of Low-mass Young Stars in Orion OB1

    Science.gov (United States)

    Kaleida, Catherine C.; Briceno, Cesar; Calvet, Nuria; Mateo, Mario L.; Hernandez, Jesus

    2015-01-01

    Surveys of pre-main sequence stars in the ~4-10 Myr range provide a window into the decline of the accretion phase of stars and the formation of planets. Nearby star clusters and stellar associations allow for the study of these young stellar populations all the way down to the lowest mass members. One of the best examples of nearby 4-10 Myr old stellar populations is the Orion OB1 association. The CIDA Variability Survey of Orion OB1 (CVSO - Briceño et al. 2001) has used the variability properties of low-mass pre-main-sequence (PMS) stars to identify hundreds of K and M-type stellar members of the Orion OB1 association, a number of them displaying IR-excess emission and thought to be representative of more evolved disk-bearing young stars. Characterizing these young, low-mass objects using spectroscopy is integral to understanding the accretion phase in young stars. We present preliminary results of a spectroscopic survey of candidate and confirmed Orion OB1 low-mass members taken during November 2014 and February 2014 using the Michigan/Magellan Fiber Spectrograph (M2FS), a PI instrument on the Magellan Clay Telescope (PI: M. Matteo). Target fields located in the off-cloud regions of Orion were identified in the CVSO, and observed using the low and high-resolution modes of M2FS. Both low and high-resolution spectra are needed in order to confirm membership and derive masses, ages, kinematics and accretion properties. Initial analysis of these spectra reveal many new K and M-type members of the Orion OB1 association in these low extinction, off-cloud areas. These are the more evolved siblings of the youngest stars still embedded in the molecular clouds, like those in the Orion Nebula Cluster. With membership and spectroscopic indicators of accretion we are building the most comprehensive stellar census of this association, enabling us to derive a robust estimate of the fraction of young stars still accreting at a various ages, a key constraint for the end of

  17. Protocol renal biopsy in patients with lupus nephritis: a single center experience.

    Science.gov (United States)

    Singh, Ametashver; Ghosh, Rabindranath; Kaur, Prabhjeet; Golay, Vishal; Pandey, Rajendra; Roychowdhury, Arpita

    2014-07-01

    Renal biopsy plays an indispensable role in the diagnosis and management of patients with lupus nephritis (LN). A number of studies have evaluated the role of a repeat biopsy in case of disease relapse or treatment unresponsiveness. We studied 40 patients with LN with renal biopsies performed at baseline and after six months of therapy. The baseline and protocol biopsies were compared with respect to histological class transformation, crescents, tubular atrophy, interstitial fibrosis and glomerulosclerosis. We also compared serum creatinine, hemoglobin, systemic lupus erythematosus disease activity index (SLEDAI) scores, 24-h urine protein excretion and C3levels as well as activity index (AI) and chronicity index (CI) at baseline and at six months. Comparison of means was made by paired t test, McNemar test and marginal homogeneity test (multinomial data). Histological class transformation was seen in 10 patients (25%). Intra-class progression to greater chronicity was seen in 10 other patients (25%).There was an increase in glomerulosclerosis, tubular atrophy, interstitial fibrosis and a reduction in cellularity, crescent formation and wire loop lesions in the protocol biopsy. A decline in AI (6.05 vs. 2.50, P protocol biopsy. Our study shows a trend toward greater chronicity in protocol biopsies in LN.

  18. Fifteen years of kidney biopsies in children: A single center in Egypt

    Directory of Open Access Journals (Sweden)

    Ashraf Bakr

    2014-01-01

    Full Text Available This study retrospectively investigates the indications and results of renal biopsy in children to determine the patterns of childhood kidney disease in a single tertiary children′s hospital in Egypt. We included all the patients who underwent ultrasound-guided renal biopsy from 1998 to 2012. All the kidney biopsies were studied under light microscopy, while immunofluorescence and electron microscopy were performed when indicated. A total of 1246 renal biopsies were performed over 15 years, on 1096 patients. The mean age of the patients at the time of biopsy was 9.2 ± 3.7 years. The main indication for a biopsy was the steroid-resistant nephrotic syndrome (n = 354, 28.4%, followed by the atypical nephrotic syndrome (n = 250, 20.1%, and renal abnormalities in the systemic diseases (n = 228, 18.3 %. In the 1226 pathologically diagnosed specimens, primary glomerulonephritis was the most common finding (n = 826, 67.4%, followed by secondary glomerulonephritis (n = 238, 19.4%. The most common causes of primary glomerulonephritis were Minimal Change Disease (MCD (n = 267, 21.8%, diffuse proliferative glomerulonephritis (n = 188, 15. 3%, and focal proliferative glomerulonephritis (n = 164, 13.3%. Lupus nephritis (n = 209, 17% was the most common cause of secondary glomerulonephritis. We conclude that the steroid-resistant nephrotic syndrome was the most frequent indication for biopsy and minimal change disease was the most common histopathological finding in our population.

  19. OB CITY–Definition of a Family-Based Intervention for Childhood Obesity Supported by Information and Communication Technologies

    Science.gov (United States)

    Hu, Ruofei; Cancela, Jorge; Cea, Gloria; Vlachopapadopoulou, Elpis-Athina; Fotiadis, Dimitrios I.; Fico, Giuseppe

    2016-01-01

    Childhood obesity is becoming one of the 21st century’s most important public health problems. Nowadays, the main treatment of childhood obesity is behavior intervention that aims at improve children’s lifestyle to arrest the disease. Information and communication technologies (ICTs) have not been widely employed in this intervention, and most of existing ICTs systems are not having a long-term effect. The purpose of this paper is to define a system to support family-based intervention through a state-of-the-art analysis of family-based interventions and related technological solutions first, and then using the analytic hierarchy process to derive a childhood obesity family-based behavior intervention model, and finally to provide a prototype of a system called OB CITY. The system makes use of applied behavior analysis, affective computing technologies, as well as serious game and gamification techniques, to offer long term services in all care dimensions of the family-based behavioral intervention aiming to provide positive effects to the treatment of childhood obesity. PMID:27602306

  20. OB CITY-Definition of a Family-Based Intervention for Childhood Obesity Supported by Information and Communication Technologies.

    Science.gov (United States)

    Hu, Ruofei; Cancela, Jorge; Arredondo Waldmeyer, Maria Teresa; Cea, Gloria; Vlachopapadopoulou, Elpis-Athina; Fotiadis, Dimitrios I; Fico, Giuseppe

    2016-01-01

    Childhood obesity is becoming one of the 21st century's most important public health problems. Nowadays, the main treatment of childhood obesity is behavior intervention that aims at improve children's lifestyle to arrest the disease. Information and communication technologies (ICTs) have not been widely employed in this intervention, and most of existing ICTs systems are not having a long-term effect. The purpose of this paper is to define a system to support family-based intervention through a state-of-the-art analysis of family-based interventions and related technological solutions first, and then using the analytic hierarchy process to derive a childhood obesity family-based behavior intervention model, and finally to provide a prototype of a system called OB CITY. The system makes use of applied behavior analysis, affective computing technologies, as well as serious game and gamification techniques, to offer long term services in all care dimensions of the family-based behavioral intervention aiming to provide positive effects to the treatment of childhood obesity.

  1. Liver biopsy in liver patients with coagulopathy

    DEFF Research Database (Denmark)

    Ott, P.; Gronbaek, H.; Clausen, M.R.

    2008-01-01

    The risk of severe bleeding after liver biopsy is estimated to be 1:12,000 in patients with near normal coagulation (INR 60 billion /l). Beyond these limits, the risk is higher, but still uncertain. The Danish guidelines require INR > 1.5, platelet count ... and normal APTT. In some instances the risk of not knowing the histology is so high that a biopsy is considered even with a more disturbed coagulation. Vitamin K, freshly frozen plasma and recombinant activated factor VII may reduce the risk of bleeding in specific situations, but no firm recommendations can...

  2. Dermatofibrosarcoma protuberans diagnosed by a single biopsy

    Directory of Open Access Journals (Sweden)

    Kristian Bakke Arvesen

    2012-07-01

    Full Text Available This brief report is about a 9 year old girl presenting with a 2.5 cm circular blue to violet discoloration on the anterolateral upper left thigh. The first biopsy taken revealed the diagnosis dermatofibrosarcoma protuberans. The patient underwent surgery at a specialized sarcoma center with post operative histology showing free wide resection margin. Preoperative chest x-ray showed no sign of metastasis. This brief report emphasizes the significance of the use of biopsy when cutaneous elements look suspicious and diagnosis is unclear.

  3. Sentinel lymph node biopsy in oral cancer

    DEFF Research Database (Denmark)

    Thomsen, Jørn Bo; Sørensen, Jens Ahm; Grupe, Peter

    2005-01-01

    PURPOSE: To validate lymphatic mapping combined with sentinel lymph node biopsy as a staging procedure, and to evaluate the possible clinical implications of added oblique lymphoscintigraphy and/or tomography and test the intra- and interobserver reproducibility of lymphoscintigraphy. MATERIAL......: Eleven (28%) patients were upstaged. The sentinel lymph node identification rate was 97.5%. Sentinel lymph node biopsy significantly differentiated between patients with or without lymph node metastasis (P = 0.001). Lymphatic mapping revealed 124 hotspots and 144 hot lymph nodes were removed by sentinel...

  4. VizieR Online Data Catalog: Properties of OB associations in IC 1613 (Garcia+, 2010)

    Science.gov (United States)

    Garcia, M.; Herrero, A.; Castro, N.; Corral, L.; Rosenberg, A.

    2014-06-01

    To understand the structure and evolution of massive stars, systematic surveys of the Local Group galaxies have been undertaken, to find these objects in environments of different chemical abundances. We focus on the metal-poor irregular galaxy IC 1613 to analyze the stellar and wind structure of its low-metallicity massive stars. We ultimately aim to study the metallicity-dependent driving mechanism of the winds of blue massive stars and use metal-poor massive stars of the Local Volume as a proxy for the stars in the early Universe. In a previous paper we produced a list of OB associations in IC 1613. Their properties are not only a powerful aid towards finding the most interesting candidate massive stars, but also reveal the structure and recent star formation history of the galaxy. We characterize these OB associations and study their connection with the galactic global properties. The reddening-free Q parameter is a powerful tool in the photometric analysis of young populations of massive stars, since it exhibits a smaller degree of degeneracy with OB spectral types than the B-V color. The color-magnitude diagram (Q vs. V) of the OB associations in IC 1613 is studied to determine their age and mass, and confirm the population of young massive stars. We identified more than 10 stars with M>=50M⊙. Spectral classification available for some of them confirm their massive nature, yet we find the common discrepancy with the spectroscopically derived masses. There is a general increasing trend of the mass of the most massive member with the number of members of each association, but not with the stellar density. The average diameter of the associations of this catalog is 40pc, half the historically considered typical size of OB associations. Size increases with the association population. The distribution of the groups strongly correlates with that of neutral and ionized hydrogen. We find the largest dispersion of association ages in the bubble region of the galaxy

  5. IPV Screening and Readiness to Respond to IPV in Ob-Gyn Settings: A Patient-Physician Study

    Directory of Open Access Journals (Sweden)

    Katherine M. Jones

    2018-01-01

    Full Text Available Purpose. Intimate partner violence (IPV is a serious, preventable public health concern that largely affects women of reproductive age. Obstetrician-gynecologists (ob-gyns have a unique opportunity to identify and support women experiencing IPV to improve women’s health. Considering recent efforts to increase IPV awareness and intervention, the present study aimed to provide a current evaluation of nationally representative samples to assess ob-gyn readiness to respond to IPV as well as patient IPV-related experiences. Methods. 400 ob-gyns were randomly selected from American College of Obstetricians and Gynecologists’ (ACOG Collaborative Ambulatory Research Network. Each physician was mailed one physician survey and 25 patient surveys. Results. IPV training/education and IPV screening practices were associated with most measures of ob-gyn readiness to respond to IPV. Among respondents, 36.8% endorsed screening all patients at annual exams; however, 36.8% felt they did not have sufficient training to assist individuals in addressing IPV. Workplace encouragement of IPV response was associated with training, screening, detection, preparation/knowledge, response practices, and resources. Thirty-one percent of patients indicated their ob-gyn had asked about possible IPV experiences during their medical visit. Conclusion. Findings highlight specific gaps in ob-gyns’ IPV knowledge and response practices to be further addressed by IPV training.

  6. The distribution and history of nuclear weapons related contamination in sediments from the Ob River, Siberia as determined by isotopic ratios of plutonium and neptunium

    International Nuclear Information System (INIS)

    Kenna, T.C.; Sayles, F.L.

    2002-01-01

    Isotopic ratios of Pu and Np measured in sediment cores from 5 locations in the Ob River drainage basin show clear evidence of input from sources other than global fallout (non-fallout sources). Historical contaminant records obtained by combining isotopic ratio information with chronological information indicate that non-fallout inputs are from several sources that have varied significantly over the past 50 years. Unique isotopic signatures observed in sediments from tributaries that drain areas containing known or suspected sources of non-fallout contamination are used to identify the source of materials in sediments collected at downstream locations. These data can lead to a better understanding of the transport behavior, fate, and relative importance of particle reactive, weapons related contaminants originating from the nuclear facilities Mayak, Tomsk-7, and Semipalitinsk, which lie within the drainage basin. From our work to date, we draw the following conclusions: (1) Persistent non-fallout contamination is observed in the Ob River above its confluence with the Irtysh River, indicating contamination from the Tomsk-7 facility. (2) Non-fallout contamination in the Tobol River above its confluence with the Irtysh River indicates contamination from the Mayak facility. (3) Non-fallout contamination in the Irtysh River above its confluence with the Tobol River indicates contamination from the Semipalitinsk weapons test site. (4) The occurrence of isotopic ratios in Ob Delta sediments that are similar to those observed in source tributaries suggests that contamination from at least two sources has been transported along the length of the river system. (5) Global fallout, a result of high-yield atmospheric weapons tests conducted by the FSU and USA primarily, is the dominant source of Pu and Np to the region; however, there have been brief periods when inputs from non-fallout sources exceeded those from global fallout

  7. Computerized determination of 3-D connectivity density in human iliac crest bone biopsies

    DEFF Research Database (Denmark)

    Thomsen, J.S.; Mosekilde, Li.; Barlach, J.

    1996-01-01

    Combining the physical disector principle with an algorithm for automatic non-linear alignment of disector pairs we have developed a software system for direct measurement of 3D connectivity densities in iliac crest bone biopsies. The method was applied to biopsies from 14 non-selected autopsy...... cases: 7 men (age range 20-84 yr) and 7 women (age range 20-86 yr). The study reveals decreases in both trabecular bone mass and connectivity density with age in women....

  8. Biopsy Needle Localization and Tracking Using ROI-RK Method

    Directory of Open Access Journals (Sweden)

    Yue Zhao

    2014-01-01

    Full Text Available ROI-RK method is a biopsy needle localization and tracking method. Previous research work has proved that it has a robust performance on different series of simulated 3D US volumes. Unfortunately, in real situations, because of the strong speckle noise of the ultrasound image and the different echogenic properties of the tissues, the real 3D US volumes have more complex background than the simulated images used previously. In this paper, to adapt the ROI-RK method in real 3D US volumes, a line-filter enhancement calculation only in the ROI is added to increase the contrast between the needle and background tissue, decreasing the phenomenon of expansion of the biopsy needle due to reverberation of ultrasound in the needle. To make the ROI-RK method more stable, a self-correction system is also implemented. Real data have been acquired on an ex vivo heart of lamb. The result of the ROI-RK method shows that it is capable to localize and track the biopsy needle in real situations, and it satisfies the demand of real-time application.

  9. Distribution of the P2X2 receptor and chemical coding in ileal enteric neurons of obese male mice (ob/ob)

    Science.gov (United States)

    Mizuno, Márcia Sanae; Crisma, Amanda Rabello; Borelli, Primavera; Schäfer, Bárbara Tavares; Silveira, Mariana Póvoa; Castelucci, Patricia

    2014-01-01

    AIM: To investigate the colocalization, density and profile of neuronal areas of enteric neurons in the ileum of male obese mice. METHODS: The small intestinal samples of male mice in an obese group (OG) (C57BL/6J ob/ob) and a control group (CG) (+/+) were used. The tissues were analyzed using a double immunostaining technique for immunoreactivity (ir) of the P2X2 receptor, nitric oxide synthase (NOS), choline acetyl transferase (ChAT) and calretinin (Calr). Also, we investigated the density and profile of neuronal areas of the NOS-, ChAT- and Calr-ir neurons in the myenteric plexus. Myenteric neurons were labeled using an NADH-diaphorase histochemical staining method. RESULTS: The analysis demonstrated that the P2X2 receptor was expressed in the cytoplasm and in the nuclear and cytoplasmic membranes only in the CG. Neuronal density values (neuron/cm2) decreased 31% (CG: 6579 ± 837; OG: 4556 ± 407) and 16.5% (CG: 7796 ± 528; OG: 6513 ± 610) in the NOS-ir and calretinin-ir neurons in the OG, respectively (P < 0.05). Density of ChAT-ir (CG: 6200 ± 310; OG: 8125 ± 749) neurons significantly increased 31% in the OG (P < 0.05). Neuron size studies demonstrated that NOS, ChAT, and Calr-ir neurons did not differ significantly between the CG and OG groups. The examination of NADH-diaphorase-positive myenteric neurons revealed an overall similarity between the OG and CG. CONCLUSION: Obesity may exert its effects by promoting a decrease in P2X2 receptor expression and modifications in the density of the NOS-ir, ChAT-ir and CalR-ir myenteric neurons. PMID:25320527

  10. CT-guided biopsy of pulmonary lesions : a comparison of diagnostic accuracy and complication rate between automated gun biopsy and fine needle aspiration biopsy

    International Nuclear Information System (INIS)

    Kim, Keon Woo; Kang, Duk Sik

    1998-01-01

    The purpose of this study is to compare the efficacy and safety of CT-guided automated gun biopsy with those of fine needle aspiration biopsy of pulmonary lesions. Under CT guidance, we performed automated gu biopsies in 115 cases of 109 patients and fine needle aspiration biopsies in 119 cases of 108 patients with pulmonary lesions. Between the two methods, we compared the diagnostic rate, diagnostic accuracy and frequency of compilations according to the depth and diameter of pulmonary lesions. The overall diagnostic rates of automated gun biopsy and fine needle aspiration biopsy were 76.5 % (88/115) and 64.7 % (77/119) respectively. There was a significant statistical difference (p=0.048), especially in the case of malignant lesions less than 3 cm (p=0.027) and more than 6 cm in maximal diameter (p=0.008), and in the lesions located from 1 cm to less than 3 cm from the pleural (p=0.030), as seen on CT. There was no significant statistical difference in the frequency of complications. Automated gun biopsy of pulmonary lesions under CT guidance is safe, with complications rate comparable to those of fine needle aspiration biopsy. A higher overall diagnostic rate can be achieved by automated gun biopsy than by fine needle aspiration biopsy. For the diagnosis of pulmonary lesions under CT guidance, automated gun biopsy is therefore a more useful procedure than fine needle aspiration biopsy. (author). 24 refs., 3 tabs

  11. Targeted MRI-guided prostate biopsy: are two biopsy cores per MRI-lesion required?

    Energy Technology Data Exchange (ETDEWEB)

    Schimmoeller, L.; Quentin, M.; Blondin, D.; Dietzel, F.; Schleich, C.; Thomas, C.; Antoch, G. [University Dusseldorf, Medical Faculty, Department of Diagnostic and Interventional Radiology, Dusseldorf (Germany); Hiester, A.; Rabenalt, R.; Albers, P.; Arsov, C. [University Dusseldorf, Medical Faculty, Department of Urology, Dusseldorf (Germany); Gabbert, H.E. [University Dusseldorf, Medical Faculty, Department of Pathology, Dusseldorf (Germany)

    2016-11-15

    This study evaluates the feasibility of performing less than two core biopsies per MRI-lesion when performing targeted MR-guided in-bore prostate biopsy. Retrospectively evaluated were 1545 biopsy cores of 774 intraprostatic lesions (two cores per lesion) in 290 patients (66 ± 7.8 years; median PSA 8.2 ng/ml) regarding prostate cancer (PCa) detection, Gleason score, and tumor infiltration of the first (FBC) compared to the second biopsy core (SBC). Biopsies were acquired under in-bore MR-guidance. For the biopsy cores, 491 were PCa positive, 239 of 774 (31 %) were FBC and 252 of 771 (33 %) were SBC (p = 0.4). Patient PCa detection rate based on the FBC vs. SBC were 46 % vs. 48 % (p = 0.6). For clinically significant PCa (Gleason score ≥4 + 3 = 7) the detection rate was 18 % for both, FBC and SBC (p = 0.9). Six hundred and eighty-seven SBC (89 %) showed no histologic difference. On the lesion level, 40 SBC detected PCa with negative FBC (7.5 %). Twenty SBC showed a Gleason upgrade from 3 + 3 = 6 to ≥3 + 4 = 7 (2.6 %) and 4 to ≥4 + 3 = 7 (0.5 %). The benefit of a second targeted biopsy core per suspicious MRI-lesion is likely minor, especially regarding PCa detection rate and significant Gleason upgrading. Therefore, a further reduction of biopsy cores is reasonable when performing a targeted MR-guided in-bore prostate biopsy. (orig.)

  12. Stereotactic core biopsy: Comparison of 11 gauge with 8 gauge vacuum assisted breast biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Venkataraman, Shambhavi, E-mail: svenkata@bidmc.harvard.edu [Department of Radiology, Beth Israel Deaconess Medical Center, 330 Brookline Avenue, Boston, MA 02215 (United States); Dialani, Vandana [Department of Radiology, Beth Israel Deaconess Medical Center, 330 Brookline Avenue, Boston, MA 02215 (United States); Gilmore, Hannah L. [Department of Pathology, UH Case Medical Center, 11100 Euclid Ave, Cleveland, OH 44106 (United States); Mehta, Tejas S. [Department of Radiology, Beth Israel Deaconess Medical Center, 330 Brookline Avenue, Boston, MA 02215 (United States)

    2012-10-15

    Purpose: The compare the performance and ability to obtain a correct diagnosis on needle biopsy between 11 gauge and 8 gauge vacuum assisted biopsy devices. Materials and methods: Hospital records of all consecutive stereotactic core biopsies performed over five years were retrospectively reviewed in compliance Health Insurance Portability and Accountability Act (HIPPA) policy and with approval from the hospital institutional review board (IRB). Pathology from core biopsy was compared with surgical pathology and/or imaging follow-up. A histological underestimation was defined if the surgical excision yielded a higher grade on pathology which changed management. Results: 828 needle core biopsies (47.5%, 393/828 with 11 gauge and 52.5%, 435/828 with 8 gauge) yielded 471 benign, 153 high risk and 204 malignant lesions. 30/193 (15.5%) 11 gauge lesions and 16/185 (8.6%) 8 gauge lesions demonstrated higher grade pathology on surgical excision. The difference in the rates of the number of correct diagnoses on core needle biopsy between 11 gauge (363/393, 92.4%) and 8 gauge (419/435, 96.3%) based on either surgical or clinical/imaging follow up and the difference in the number of discordant benign core biopsies between 11 (17/217, 7.8%) and 8 gauge (4/254, 1.6%) necessitating a surgical biopsy was significant (P = 0.013; P = 0.001). Although there were more underestimations with the 11 gauge (25/193, 13.0%) than 8 gauge (15/185, 8.1%) needle, this was not significant. Conclusion: Our study demonstrates improved performance and increased diagnostic ability of 8 gauge needle over 11 gauge in obtaining a correct diagnosis on needle biopsy.

  13. Targeted MRI-guided prostate biopsy: are two biopsy cores per MRI-lesion required?

    International Nuclear Information System (INIS)

    Schimmoeller, L.; Quentin, M.; Blondin, D.; Dietzel, F.; Schleich, C.; Thomas, C.; Antoch, G.; Hiester, A.; Rabenalt, R.; Albers, P.; Arsov, C.; Gabbert, H.E.

    2016-01-01

    This study evaluates the feasibility of performing less than two core biopsies per MRI-lesion when performing targeted MR-guided in-bore prostate biopsy. Retrospectively evaluated were 1545 biopsy cores of 774 intraprostatic lesions (two cores per lesion) in 290 patients (66 ± 7.8 years; median PSA 8.2 ng/ml) regarding prostate cancer (PCa) detection, Gleason score, and tumor infiltration of the first (FBC) compared to the second biopsy core (SBC). Biopsies were acquired under in-bore MR-guidance. For the biopsy cores, 491 were PCa positive, 239 of 774 (31 %) were FBC and 252 of 771 (33 %) were SBC (p = 0.4). Patient PCa detection rate based on the FBC vs. SBC were 46 % vs. 48 % (p = 0.6). For clinically significant PCa (Gleason score ≥4 + 3 = 7) the detection rate was 18 % for both, FBC and SBC (p = 0.9). Six hundred and eighty-seven SBC (89 %) showed no histologic difference. On the lesion level, 40 SBC detected PCa with negative FBC (7.5 %). Twenty SBC showed a Gleason upgrade from 3 + 3 = 6 to ≥3 + 4 = 7 (2.6 %) and 4 to ≥4 + 3 = 7 (0.5 %). The benefit of a second targeted biopsy core per suspicious MRI-lesion is likely minor, especially regarding PCa detection rate and significant Gleason upgrading. Therefore, a further reduction of biopsy cores is reasonable when performing a targeted MR-guided in-bore prostate biopsy. (orig.)

  14. Core biopsies of the breast: Diagnostic pitfalls

    Directory of Open Access Journals (Sweden)

    Megha Joshi

    2011-01-01

    Full Text Available The incidence of breast cancer is increasing worldwide. In this review article, the authors compare and contrast the incidence of breast cancer, and the inherent differences in the United States (US and India in screening techniques used for diagnosing breast cancer. In spite of these differences, core biopsies of the breast are common for diagnosis of breast cancer in both countries. The authors describe "Best Practices" in the reporting and processing of core biopsies and in the analysis of estrogen receptor (ER, progesterone receptor (PR, and human epidermal growth factor Receptor 2 (Her2/neu. The pitfalls in the diagnosis of fibroepithelial lesions of the breast on core biopsy are discussed, as also the significance of pseudoangiomatous stromal hyperplasia of the breast (PASH is discussed in core biopsy. In this review, the management and diagnosis of flat epithelial atypia and radiation atypia are elaborated and the use of immunohistochemistry (IHC in papillary lesions, phyllodes tumor, and complex sclerosing lesions (radial scars is illustrated. Rarer lesions such as mucinous and histiocytoid carcinoma are also discussed.

  15. Ultrasound- and MRI-Guided Prostate Biopsy

    Science.gov (United States)

    ... assistance of a nurse and an MR imaging technologist. As with the ultrasound procedure, you may receive antibiotics, sedatives and pain medication before the biopsy. The MRI-guided procedure may use contrast ... A nurse or technologist will insert an intravenous (IV) catheter into a ...

  16. Protective Capnothorax During Transthoracic Needle Biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Kavanagh, John, E-mail: jokavana@tcd.ie; Siemienowicz, Miranda L.; Lyen, Stephen; Kandel, Sonja; Rogalla, Patrik [University of Toronto, Division of Cardiothoracic Imaging, Joint Department of Medical Imaging, University Health Network and Mount Sinai Hospital (Canada)

    2017-04-15

    PurposeTransthoracic needle biopsy (TTNB) is an established procedure in the management of pulmonary nodules. The most common complications are directly related to crossing the lung or visceral pleura during the biopsy. In this study, we describe the use of carbon dioxide instead of room air to create a protective “capnothorax” during TTNB.Materials and MethodsFive patients underwent creation of a capnothorax during TTNB. Parameters recorded were location and size of target, distance from pleura, length of procedure, volume of carbon dioxide, periprocedural complications and biopsy result.ResultsInduction of capnothorax was successful in all cases. In two patients, a continuous infusion of carbon dioxide was required to maintain an adequate volume of intrapleural gas. In two patients, the carbon dioxide resolved spontaneously and in the remaining patients it was aspirated at the end of the procedure. All biopsies were diagnostic with no periprocedural or postprocedural complications.ConclusionThis study suggests that protective iatrogenic capnothorax is a safe and effective technique during TTNB. The intrinsic properties and availability of carbon dioxide make it an attractive alternative to room air.

  17. Unusual presentation and inconclusive biopsy render fibroadenoma ...

    African Journals Online (AJOL)

    Two young, nonlactating, nulliparous women presented with acutely painful breast masses. Sonographic features showed mixed echogenic masses. Core biopsies were not diagnostic, and surgical excision revealed infarcted fibroadenomas in both cases. Although fibroadenomas are common, they do not commonly infarct, ...

  18. Documenting the location of systematic transrectal ultrasound-guided prostate biopsies: correlation with multi-parametric MRI.

    Science.gov (United States)

    Turkbey, Baris; Xu, Sheng; Kruecker, Jochen; Locklin, Julia; Pang, Yuxi; Shah, Vijay; Bernardo, Marcelino; Baccala, Angelo; Rastinehad, Ardeshir; Benjamin, Compton; Merino, Maria J; Wood, Bradford J; Choyke, Peter L; Pinto, Peter A

    2011-03-29

    During transrectal ultrasound (TRUS)-guided prostate biopsies, the actual location of the biopsy site is rarely documented. Here, we demonstrate the capability of TRUS-magnetic resonance imaging (MRI) image fusion to document the biopsy site and correlate biopsy results with multi-parametric MRI findings. Fifty consecutive patients (median age 61 years) with a median prostate-specific antigen (PSA) level of 5.8 ng/ml underwent 12-core TRUS-guided biopsy of the prostate. Pre-procedural T2-weighted magnetic resonance images were fused to TRUS. A disposable needle guide with miniature tracking sensors was attached to the TRUS probe to enable fusion with MRI. Real-time TRUS images during biopsy and the corresponding tracking information were recorded. Each biopsy site was superimposed onto the MRI. Each biopsy site was classified as positive or negative for cancer based on the results of each MRI sequence. Sensitivity, specificity, and receiver operating curve (ROC) area under the curve (AUC) values were calculated for multi-parametric MRI. Gleason scores for each multi-parametric MRI pattern were also evaluated. Six hundred and 5 systemic biopsy cores were analyzed in 50 patients, of whom 20 patients had 56 positive cores. MRI identified 34 of 56 positive cores. Overall, sensitivity, specificity, and ROC area values for multi-parametric MRI were 0.607, 0.727, 0.667, respectively. TRUS-MRI fusion after biopsy can be used to document the location of each biopsy site, which can then be correlated with MRI findings. Based on correlation with tracked biopsies, T2-weighted MRI and apparent diffusion coefficient maps derived from diffusion-weighted MRI are the most sensitive sequences, whereas the addition of delayed contrast enhancement MRI and three-dimensional magnetic resonance spectroscopy demonstrated higher specificity consistent with results obtained using radical prostatectomy specimens.

  19. EFFICACY OF IMMUNOHISTOCHEMISTRY IN PROSTATE NEEDLE BIOPSIES

    Directory of Open Access Journals (Sweden)

    Tameem Afroz

    2016-10-01

    Full Text Available BACKGROUND Prostate needle biopsies can pose a major diagnostic challenge when it comes to differentiating adenocarcinoma and its variants from its benign mimics. In needle biopsies, when the suspicious focus is small, morphological features may not suffice to differentiate it from its morphologic mimics like atrophy, basal cell hyperplasia, reactive inflammatory changes, seminal vesicles and adenosis. Immunohistochemical marker for basal cells, p63 and prostate cancer specific marker, Alpha-Methylacyl-CoA Racemase (AMACR help in overcoming such diagnostic dilemmas. MATERIALS AND METHODS We analysed 157 prostate core needle biopsies over a period of 2 years. Routine Hematoxylin and Eosin (H and E sections and immunohistochemical markers for basal cells (p63 and prostate cancer specific marker (AMACR were used. Prospective study was done on prostate needle core biopsies. Biopsy was done under ultrasound guidance with an 18-gauge needle. Biopsy was done in patients with raised serum PSA levels for exclusion of prostate carcinoma. RESULTS Over a period of two years, 157 prostate core needle biopsies were studied. 83 were benign lesions comprising 69 benign prostatic hyperplasias, five basal cell hyperplasias, four granulomatous lesions and three showed atrophic changes. Two biopsies morphologically resembled seminal vesicles. Prostate cancer specific marker, AMACR was negative in all, but two lesions. In these two lesions, it showed weak nonspecific staining. Basal cell marker p63 showed a continuous staining pattern highlighting the basal cells in all the 69 cases of benign prostatic hyperplasia, 5 cases of basal hyperplasia showed positivity in all the hyperplastic basal cells. In the two cases of seminal vesicles, it showed intense basal cell positivity. It showed a discontinuous pattern in two of the four granulomatous lesions and showed a weak, but a continuous staining pattern in the atrophic lesions. 74 were adenocarcinomas; the predominant

  20. Implementation of BIRADSTM together with an organization of percutaneous breast biopsies: experiences, reactions

    International Nuclear Information System (INIS)

    Hergan, K.; Oser, W.; Laengle, I.

    2002-01-01

    Purpose: To record the acceptance and reactions of radiologist und physicians who recommend patients for mammography after simultaneous establishment of BIRADS TM and a registration of the results of percutaneous breast biopsies. Materials and methods: To improve clarity of mammographic reports and to provide guidance concerning any necessary percutaneous breast biopsies the Breast Imaging Data And Reporting System (BIRADS TM ) has been introduced regionally together with a registration of percutaneous breast biopsies. Using a questionnaire, 25 radiologists and 230 referring physicians were asked on acceptance and reactions concerning the established system. Results: Of the 15 answering radiologists, 93% considered BIRADS TM a worthwhile effort and 87% found the biopsy guidelines to be useful. They regarded the acceptance of the referring physicians and patients as high (80%). Up to 69% of the 52 participating physicians stated a better understanding of the mammographic reports, an easier comprehension of the dignity classification of a mammographic lesion and the feeling of an improvement in their work. Preoperative assessment of histology was found to be valuable by 94% of the referring physicians. They believe that more than half of the patients benefit from the biopsy guidelines and that the majority of patients accept this approach. Conclusion: BIRADS TM is useful to standardize and improve mammographic reports. It is advantageous to link BIRADS TM with guidelines for percutaneous breast biopsies. (orig.) [de

  1. Multi-institutional Evaluation of Upper Urinary Tract Biopsy Using Backloaded Cup Biopsy Forceps, a Nitinol Basket, and Standard Cup Biopsy Forceps.

    Science.gov (United States)

    Lama, Daniel J; Safiullah, Shoaib; Patel, Roshan M; Lee, Thomas K; Balani, Jyoti P; Zhang, Lishi; Okhunov, Zhamshid; Margulis, Vitaly; Savage, Stephen J; Uchio, Edward; Landman, Jaime

    2018-04-06

    To compare the performance of 3 contemporary ureteroscopic biopsy devices for the histopathologic diagnosis of upper tract urothelial carcinoma (UTUC). We retrospectively reviewed 145 patients who underwent 182 urothelial biopsies using 2.4F backloaded cup biopsy forceps, a nitinol basket, or 3F standard cup biopsy forceps at 3 tertiary academic centers between 2011 and 2016. Experienced genitourinary pathologists provided an assessment of each specimen without knowledge of the device used for biopsy. For patients who underwent nephroureterectomy without neoadjuvant chemotherapy within 3 months of biopsy-proven UTUC diagnosis, the biopsy grade was compared with both the grade and stage of the surgical specimen. Biopsy utilization varied among the 3 institutions (P cup forceps was rated similarly to the nitinol basket (P >.05) and was favored over standard cup forceps specimens. Grade concordance was not affected by specimen size (P >.05), morphology (P >.1), or location (P >.5). No difference existed among the devices in the rate of acquiring a grade concordant biopsy; however, the backloaded cup forceps provided concordant biopsies that could be distinguished as low- and high-grade (P = .02). The backloaded cup forceps and nitinol basket obtained a higher quality urothelial specimen compared with standard cup forceps. Ureteroscopic biopsy device selection did not significantly impact the accuracy of the histologic diagnosis of UTUC. Copyright © 2018 Elsevier Inc. All rights reserved.

  2. Complications of percutaneous renal tumor biopsy: An analysis of 340 consecutive biopsies

    DEFF Research Database (Denmark)

    René Rasmussen, Lars; Loft, Martina; Høyer, Søren

    Purpose Ultrasound Guided Percutaneous Kidney Biopsy (UGPKB) plays a major role in diagnosis of renal tumours. There seems to be little consensus regarding post-biopsy observation period. We aim to identify complications in UGPKB among outpatients with a suspected malignant renal lesion as well...... as the timing of onset of these complications, helping to clarify the optimal observation period. Many studies in this field suggest a lower complication risk for outpatients compared to hospitalized patients. In the latter group, an observation period of 24h after biopsy is often recommended. Material...... discrepancy. Results As for one third of the patients, analysed up until now, we find a total of one major complication and a few minor, all arisen within less than 6 hours after biopsy. Conclusions Rates of both major and minor complications in UGPKB are very low suggesting a shorter observation period...

  3. Not all stars form in clusters - measuring the kinematics of OB associations with Gaia

    Science.gov (United States)

    Ward, Jacob L.; Kruijssen, J. M. Diederik

    2018-04-01

    It is often stated that star clusters are the fundamental units of star formation and that most (if not all) stars form in dense stellar clusters. In this monolithic formation scenario, low-density OB associations are formed from the expansion of gravitationally bound clusters following gas expulsion due to stellar feedback. N-body simulations of this process show that OB associations formed this way retain signs of expansion and elevated radial anisotropy over tens of Myr. However, recent theoretical and observational studies suggest that star formation is a hierarchical process, following the fractal nature of natal molecular clouds and allowing the formation of large-scale associations in situ. We distinguish between these two scenarios by characterizing the kinematics of OB associations using the Tycho-Gaia Astrometric Solution catalogue. To this end, we quantify four key kinematic diagnostics: the number ratio of stars with positive radial velocities to those with negative radial velocities, the median radial velocity, the median radial velocity normalized by the tangential velocity, and the radial anisotropy parameter. Each quantity presents a useful diagnostic of whether the association was more compact in the past. We compare these diagnostics to models representing random motion and the expanding products of monolithic cluster formation. None of these diagnostics show evidence of expansion, either from a single cluster or multiple clusters, and the observed kinematics are better represented by a random velocity distribution. This result favours the hierarchical star formation model in which a minority of stars forms in bound clusters and large-scale, hierarchically structured associations are formed in situ.

  4. WNIN/GR-Ob - an insulin-resistant obese rat model from inbred WNIN strain.

    Science.gov (United States)

    Harishankar, N; Vajreswari, A; Giridharan, N V

    2011-09-01

    WNIN/GR-Ob is a mutant obese rat strain with impaired glucose tolerance (IGT) developed at the National Institute of Nutrition (NIN), Hyderabad, India, from the existing 80 year old Wistar rat (WNIN) stock colony. The data presented here pertain to its obese nature along with IGT trait as evidenced by physical, physiological and biochemical parameters. The study also explains its existence, in three phenotypes: homozygous lean (+/+), heterozygous carrier (+/-) and homozygous obese (-/-). Thirty animals (15 males and 15 females) from each phenotype (+/+, +/-, -/-) and 24 lean and obese (6 males and 6 females) rats were taken for growth and food intake studies respectively. Twelve adult rats from each phenotype were taken for body composition measurement by total body electrical conductivity (TOBEC); 12 rats of both genders from each phenotype at different ages were taken for clinical chemistry parameters. Physiological indices of insulin resistance were calculated according to the homeostasis model assessment for insulin resistance (HOMA-IR) and also by studying U¹⁴C 2-deoxy glucose uptake (2DG). WNINGR-Ob mutants had high growth, hyperphagia, polydipsia, polyurea, glycosuria, and significantly lower lean body mass, higher fat mass as compared with carrier and lean rats. These mutants, at 50 days of age displayed abnormal response to glucose load (IGT), hyperinsulinaemia, hypertriglyceridaemia, hypercholesterolaemia and hyperleptinaemia. Basal and insulin-stimulated glucose uptakes by diaphragm were significantly decreased in obese rats as compared with lean rats. Obese rats of the designated WNIN/GR-Ob strain showed obesity with IGT, as adjudged by physical, physiological and biochemical indices. These indices varied among the three phenotypes, being lowest in lean, highest in obese and intermediate in carrier phenotypes thereby suggesting that obesity is inherited as autosomal incomplete dominant trait in this strain. This mutant obese rat model is easy to

  5. Development of the TeamOBS-PPH - targeting clinical performance in postpartum hemorrhage.

    Science.gov (United States)

    Brogaard, Lise; Hvidman, Lone; Hinshaw, Kim; Kierkegaard, Ole; Manser, Tanja; Musaeus, Peter; Arafeh, Julie; Daniels, Kay I; Judy, Amy E; Uldbjerg, Niels

    2018-06-01

    This study aimed to develop a valid and reliable TeamOBS-PPH tool for assessing clinical performance in the management of postpartum hemorrhage (PPH). The tool was evaluated using video-recordings of teams managing PPH in both real-life and simulated settings. A Delphi panel consisting of 12 obstetricians from the UK, Norway, Sweden, Iceland, and Denmark achieved consensus on (i) the elements to include in the assessment tool, (ii) the weighting of each element, and (iii) the final tool. The validity and reliability were evaluated according to Cook and Beckman. (Level 1) Four raters scored four video-recordings of in situ simulations of PPH. (Level 2) Two raters scored 85 video-recordings of real-life teams managing patients with PPH ≥1000 mL in two Danish hospitals. (Level 3) Two raters scored 15 video-recordings of in situ simulations of PPH from a US hospital. The tool was designed with scores from 0 to 100. (Level 1) Teams of novices had a median score of 54 (95% CI 48-60), whereas experienced teams had a median score of 75 (95% CI 71-79; p < 0.001). (Level 2) The intra-rater [intra-class correlation (ICC) = 0.96] and inter-rater (ICC = 0.83) agreements for real-life PPH were strong. The tool was applicable in all cases: atony, retained placenta, and lacerations. (Level 3) The tool was easily adapted to in situ simulation settings in the USA (ICC = 0.86). The TeamOBS-PPH tool appears to be valid and reliable for assessing clinical performance in real-life and simulated settings. The tool will be shared as the free TeamOBS App. © 2018 Nordic Federation of Societies of Obstetrics and Gynecology.

  6. OB ASSOCIATIONS AT THE UPPER END OF THE MILKY WAY LUMINOSITY FUNCTION

    Energy Technology Data Exchange (ETDEWEB)

    Rahman, Mubdi; Matzner, Christopher D.; Moon, Dae-Sik, E-mail: mubdi@pha.jhu.edu [Department of Astronomy and Astrophysics, University of Toronto, 50 St. George Street, Toronto, ON M5S 3H8 (Canada)

    2013-04-01

    The Milky Way's most luminous, young, and massive (M {approx}> 10{sup 4} M{sub Sun }) star clusters and OB associations have largely evaded detection despite knowledge of their surrounding H II regions. We search for these clusters and associations within the 40 star-forming complexes from Rahman and Murray in the 13 most luminous Wilkinson Microwave Anisotropy Probe (WMAP) free-free emission sources of the Galaxy. Selecting for objects with the dust-reddened colors of OB stars, we identify new candidate associations using the Two Micron All Sky Survey point-source catalog. In 40 star-forming complexes searched, 22 contain cluster/association candidates with sizes and masses in the range of 3'-26' and 10{sup 2.3}-10{sup 5} M{sub Sun }. Of the 22 candidates, at least seven have estimated masses {approx}> 10{sup 4} M{sub Sun }, doubling the number of such massive clusters known in the Galaxy. Only one of the searched WMAP sources remains without a candidate. Applying our method to a statistically similar set of test locations, we estimate that 3.0 {+-} 0.6 of our 22 candidate associations are unrelated to the star-forming complexes. In addition, the apparent extinctions of our candidate associations correlate well with the predictions from a Galactic model. These facts, along with the clear detection of a known OB association and the previous spectral verification of one cluster found by this method, validate our method. In eight of the most luminous WMAP sources, the candidate associations can account for the observed free-free flux. With our new compilation, the Galactic census of young, massive stellar associations may now be about half complete.

  7. Ultrasound-guided fine needle aspiration versus core needle biopsy: comparison of post-biopsy hematoma rates and risk factors.

    Science.gov (United States)

    Chae, In Hye; Kim, Eun-Kyung; Moon, Hee Jung; Yoon, Jung Hyun; Park, Vivian Y; Kwak, Jin Young

    2017-07-01

    To compare post-biopsy hematoma rates between ultrasound guided-fine needle aspiration and ultrasound guided-core needle biopsy, and to investigate risk factors for post-biopsy hematoma. A total of 5304 thyroid nodules which underwent ultrasound guided biopsy were included in this retrospective study. We compared clinical and US features between patients with and without post-biopsy hematoma. Associations between these features and post-biopsy hematoma were analyzed. Post-biopsy hematoma rate was 0.8% (43/5121) for ultrasound guided-fine needle aspiration and 4.9% (9/183) for ultrasound guided-core needle biopsy (P core needle biopsy (9/179, 5.0%) than with ultrasound guided-fine needle aspiration (9/1138, 0.8%) (P core needle biopsy was the only significant risk factor for post-biopsy hematoma (adjusted Odds Ratio, 6.458, P core needle biopsy than in ultrasound guided-fine needle aspiration and ultrasound guided-core needle biopsy was the only independent factor of post-biopsy hematoma in thyroid nodules.

  8. Nature vs. Nurture: The influence of OB star environments on proto-planetary disk evolution

    Science.gov (United States)

    Bouwman, Jeroen

    2006-09-01

    We propose a combined IRAC/IRS study of a large, well-defined and unbiased X-ray selected sample of pre-main-sequence stars in three OB associations: Pismis 24 in NGC 6357, NGC 2244 in the Rosette Nebula, and IC 1795 in the W3 complex. The samples are based on recent Chandra X-ray Observatory studies which reliably identify hundreds of cluster members and were carefully chosen to avoid high infrared nebular background. A new Chandra exposure of IC 1795 is requested, and an optical followup to characterise the host stars is planned.

  9. Polimorfismos del gen ob en bovinos de raza holstein en la Comarca Lagunera, México

    OpenAIRE

    Sarai S. Mendoza-Retana; Miguel A. Gallegos-Robles; Uriel González-Salas; José L. García-Hernández; Manuel Fortis-Hernández; Cirilo Vázquez-Vázquez; Héctor I. Trejo-Escareño

    2017-01-01

    La Comarca Lagunera es la cuenca lechera más importante de México. En la actualidad se están utilizando diversas técnicas que permiten evaluar genéticamente el animal a una edad temprana, permitiendo seleccionar futuros reproductores con características deseables. Entre los genes relacionados con la producción de leche, se encuentran el gen Ob también llamado gen Leptina el cual actúa sobre el sistema nervioso central y tejidos periféricos jugando un papel muy importante ...

  10. Direct Imaging and Spectroscopy of a Young Extrasolar Kuiper Belt in the Nearest OB Association

    OpenAIRE

    Currie, Thayne; Lisse, Carey M.; Kuchner, Marc J.; Madhusudhan, Nikku; Kenyon, Scott J.; Thalmann, Christian; Carson, Joseph; Debes, John H.

    2015-01-01

    We describe the discovery of a bright, young Kuiper belt-like debris disk around HD 115600, a $\\sim$ 1.4--1.5 M$_\\mathrm{\\odot}$, $\\sim$ 15 Myr old member of the Sco-Cen OB Association. Our H-band coronagraphy/integral field spectroscopy from the \\textit{Gemini Planet Imager} shows the ring has a (luminosity scaled) semi major axis of ($\\sim$ 22 AU) $\\sim$ 48 AU, similar to the current Kuiper belt. The disk appears to have neutral scattering dust, is eccentric (e $\\sim$ 0.1--0.2), and could b...

  11. Eukaryotic RNA polymerase subunit RPB8 is a new relative of the OB family.

    Science.gov (United States)

    Krapp, S; Kelly, G; Reischl, J; Weinzierl, R O; Matthews, S

    1998-02-01

    RNA polymerase II subunit RPB8 is an essential subunit that is highly conserved throughout eukaryotic evolution and is present in all three types of nuclear RNA polymerases. We report the first high resolution structural insight into eukaryotic RNA polymerase architecture with the solution structure of RPB8 from Saccharomyces cerevisiae. It consists of an eight stranded, antiparallel beta-barrel, four short helical regions and a large, unstructured omega-loop. The strands are connected in classic Greek-key fashion. The overall topology is unusual and contains a striking C2 rotational symmetry. Furthermore, it is most likely a novel associate of the oligonucleotide/oligosaccharide (OB) binding protein class.

  12. BOREAS TF-8 NSA-OJP and SSA-OBS Ceilometer Data

    Science.gov (United States)

    Moore, Kathleen E.; Hall, Forrest G. (Editor); Huemmrich, Karl (Editor); Fitzjarrald, David R.

    2000-01-01

    The BOREAS TF-8 team used ceilometers to collect data on the fraction of the sky covered with clouds and the cloud height. Included with these data is the surface-based lifting condensation level, derived from temperature and humidity values acquired at the flux tower at the NSA-OJP site. Ceilo-meter data were collected at the NSA-OJP site in 1994 and at the NSA-OJP and SSA-OBS sites in 1996. The data are available in tabular ASCII files. The data files are available on a CD-ROM (see document number 20010000884).

  13. MR imaging-guided vacuum-assisted breast biopsy: Reduction of false-negative biopsies by short-term control MRI 24–48 h after biopsy

    International Nuclear Information System (INIS)

    Bahrs, S.D.; Hattermann, V.; Preibsch, H.; Hahn, M.; Staebler, A.; Claussen, C.D.; Siegmann-Luz, K.C.

    2014-01-01

    Aim: To evaluate whether another contrast-enhanced (CE) magnetic resonance imaging (MRI) examination 24–48 h after MRI-guided vacuum-assisted breast biopsy (MRI-VAB) can reduce the rate of false-negative cases. Materials and methods: The study included 252 patients who underwent MRI-VAB for the clarification of 299 lesions. The success of MRI-VAB was assessed at interventional MRI and another CE MRI 24–48 h after the intervention. In cases of successful MRI-VAB (complete or partial lesion removal) and benign histological results, follow-up breast MRI was performed. In cases of unsuccessful biopsy (unchanged lesion), tissue sampling was repeated. False-negative cases were calculated to assess the diagnostic value of MRI follow-up within 2 days after intervention. Results: Ninety-eight malignant (32.8%) and 201 (67.2%) benign lesions were diagnosed using MRI-VAB. At immediate unenhanced control MRI, all lesions were assessed as successfully biopsied. In 18 benign cases (6%), CE MRI after 24–48 h showed an unsuccessful intervention. Further tissue sampling revealed another 13 cancers in these patients. This results in a false-negative rate of 11.7%. Follow-up MRI of the benign lesions presented no further malignancy. Conclusions: MRI-VAB with immediate unenhanced control offers a success rate of 94%. The rate of false-negative biopsies (11.7%) could be reduced to zero by using short-term follow-up MRI. Therefore, a further CE breast MRI 24–48 h after benign MRI-VAB to eliminate missed cancers is recommended. - Highlights: • Some suspicious breast lesions are only seen on MRI. • They can be biopsied by a MRI-guided vacuum-assisted biopsy system. • Inadequate sampling causes some false-negative biopsies. • We evaluate an additional control MRI 24 to 48 hours after biopsy. • A reduced rate of the false-negative biopsies was found

  14. Percutaneous biopsy of a metastatic common iliac lymph node using hydrodissection and a semi-automated biopsy gun

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, Seong Yoon; Park, Byung Kwan [Dept. of Radiology, amsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2017-06-15

    Percutaneous biopsy is a less invasive technique for sampling the tissue than laparoscopic biopsy or exploratory laparotomy. However, it is difficult to perform biopsy of a deep-seated lesion because of the possibility of damage to the critical organs. Recently, we successfully performed CT-guided biopsy of a metastatic common iliac lymph node using hydrodissection and semi-automated biopsy devices. The purpose of this case report was to show how to perform hydrodissection and how to use a semi-automated gun for safe biopsy of a metastatic common iliac lymph node.

  15. MR-guided biopsies of undetermined liver lesions: technique and results; MRT-gezielte perkutane Biopsie bei unklaren fokalen Leberlaesionen: Technik und Ergebnisse

    Energy Technology Data Exchange (ETDEWEB)

    Zangos, S.; Kiefl, D.; Eichler, K.; Engelmann, K.; Heller, M.; Herzog, C.; Mack, M.G.; Jacobi, V.; Vogl, T.J. [Inst. fuer Diagnostische und Interventionelle Radiologie, Johann-Wolfgang-Goethe-Univ. Frankfurt (Germany)

    2003-05-01

    Purpose: To evaluate safety and precision of liver tumor biopsies performed in an open low field system using different sequence techniques. Materials and Methods: In 47 patients with liver tumors, MR-guided biopsies were performed in a low field system (0.2 Tesla, Magnetom Open, Siemens) using two different sequences. The procedure was monitored with T1-weighted FLASH sequences (TR/TE = 100/9; 70 ) in all patients and with FISP-Rotated-Keyhole-sequence (TR/TE = 18/8; 90 ) in additional 20 patients. After positioning of the needle tip in the tumors, 166 biopsy specimens were acquired with 16 G cutting needles (Somatex{sup *}). The diameter of the biopsied lesions ranged from 1 to 10 cm (mean diameter 3.2 cm). Visibility of the needles and precision of the biopsies were evaluated. Results: All interventional biopsies were performed without vascular or organ injuries. Adequate specimens for histologic interpretation were obtained in 42 cases (89.3%). The biopsy results were non-specific in 2 patients (4.2%) and the lesions missed in 3 patients (6.3%). Mean in-room time was 35 minutes and the intervention time was 8.3 minutes. T1-weighted FLASH images proved optimal for confirming needle-tip placement during the biopsies or punctures. Organs, tumors and vessels were easily identified. The FISP sequence proved to be inferior in visualizing vessels and tumors. Conclusion: MR-guided liver biopsies are safely and precisely performed using T1-weighted FLASH-sequences with sufficient visualization of the lesions and might be complementary to US- or CT-guided biopsies. (orig.) [German] Zielsetzung: Evaluierung der Sicherheit und Genauigkeit MRT-gezielter Leberbiopsien unter Verwendung verschiedener Sequenzen. Methoden: Bei 47 Patienten mit unklaren Leberlaesionen wurden in einem offenen 0,2-Tesla-MR-System (Magnetom Open, Siemens) bildgesteuerte Biopsien unter Verwendung von zwei verschiedenen Sequenzen durchgefuehrt. Die Bildgebung erfolgte bei allen Patienten mittels T

  16. Single-Pass Percutaneous Liver Biopsy for Diffuse Liver Disease Using an Automated Device: Experience in 154 Procedures

    International Nuclear Information System (INIS)

    Rivera-Sanfeliz, Gerant; Kinney, Thomas B.; Rose, Steven C.; Agha, Ayad K.M.; Valji, Karim; Miller, Franklin J.; Roberts, Anne C.

    2005-01-01

    Purpose: To describe our experience with ultrasound (US)-guided percutaneous liver biopsies using the INRAD 18G Express core needle biopsy system.Methods: One hundred and fifty-four consecutive percutaneous core liver biopsy procedures were performed in 153 men in a single institution over 37 months. The medical charts, pathology reports, and radiology files were retrospectively reviewed. The number of needle passes, type of guidance, change in hematocrit level, and adequacy of specimens for histologic analysis were evaluated.Results: All biopsies were performed for histologic staging of chronic liver diseases. The majority of patients had hepatitis C (134/153, 90.2%). All patients were discharged to home after 4 hr of postprocedural observation. In 145 of 154 (94%) biopsies, a single needle pass was sufficient for diagnosis. US guidance was utilized in all but one of the procedures (153/154, 99.4%). The mean hematocrit decrease was 1.2% (44.1-42.9%). Pain requiring narcotic analgesia, the most frequent complication, occurred in 28 of 154 procedures (18.2%). No major complications occurred. The specimens were diagnostic in 152 of 154 procedures (98.7%).Conclusions: Single-pass percutaneous US-guided liver biopsy with the INRAD 18G Express core needle biopsy system is safe and provides definitive pathologic diagnosis of chronic liver disease. It can be performed on an outpatient basis. Routine post-biopsy monitoring of hematocrit level in stable, asymptomatic patients is probably not warranted

  17. Adipose cell differentiation: evidence for a two-step process in the polyamine-dependent Ob1754 clonal line.

    Science.gov (United States)

    Amri, E Z; Dani, C; Doglio, A; Etienne, J; Grimaldi, P; Ailhaud, G

    1986-01-01

    A subclone of preadipocyte Ob17 cells has been isolated (Ob1754 clonal line). Confluent Ob1754 cells treated with an inhibitor of spermidine and spermine synthesis, methylglyoxal bis(guanylhydrazone), were totally dependent upon putrescine addition for the expression of glycerol-3-phosphate dehydrogenase which behaved as a late marker of adipose conversion. Under these conditions, the early expression of lipoprotein lipase during growth arrest remained unchanged. Studies at the mRNA level showed that the expression of unidentified pOb24 and pGH3 mRNAs, which was parallel to that of lipoprotein lipase, is independent of polyamine addition whereas the late emergence of glycerol-3-phosphate dehydrogenase mRNA was putrescine-dependent and co-ordinated with the expression of pAL422 mRNA encoding for a myelin-P2 homologue [Bernlohr, Angus, Lane, Bolanowski & Kelly (1984) Proc. Natl. Acad. Sci. U.S.A. 81, 5468-5472]. The appearance of lipoprotein lipase preceded DNA synthesis and post-confluent mitoses which were both putrescine-dependent and which took place before the appearance of glycerol-3-phosphate dehydrogenase. Thus the adipose conversion of Ob1754 cells involves the expression of at least two separate sets of markers which are differently regulated. Images Fig. 3. Fig. 6. PMID:3800927

  18. Liver CT-guided aspirative biopsies

    International Nuclear Information System (INIS)

    Santos, Gilda da Cunha; Carvalho, Leda Viegas de; Chojniak, Rubens; Morini, Sandra Regina

    1996-01-01

    Sixty-eight CT-guided aspirative biopsies of hepatic nodules were performed at A.C. Camargo Hospital, Sao Paulo, Brazil, from 1992 to 1995. The cases were distributed as follow: 44(64.7%) with a positive diagnosis for neoplastic cells, 6(8.8%) with a negative diagnosis, and 14 (20.5%) with insufficient material. Of the positive cases (primary neoplasias and metastases), the cytological diagnosis was achieved in 39 cases. There were 36 cases of carcinoma (7 hepato carcinomas, 18 adenocarcinomas, 1 small cell carcinoma and 10 cases of unspecified differentiation), 2 cases of melanoma and 1 case of melanoma and 1 case of sarcoma. The correlation with histopathological exams showed no false positive cases and concordance between cytological and histopathological diagnosis. The results demonstrate that CT-guided aspirative biopsy of hepatic nodules permits a rapid diagnosis of neoplastic lesions, especially for the evaluation of metastases. (author)

  19. PATHOMORPHOLOGY OF ZERO BIOPSIES OF DONOR KIDNEYS

    Directory of Open Access Journals (Sweden)

    M. L. Arefjev

    2011-01-01

    Full Text Available There is well known fact that kidney transplants from Extended Criteria Donors may increase risk of De- layed Graft Function and Primary Non-Function of transplants. We have collected and tested 65 «zero» kidney biopsies from cadaver donors aged from 19 to 71 years old. In the pool of elderly donors who died from cerebrovascular accident the frequency of nephrosclerosis presentation was higher than in donors of yonger age who died from craniocephalic trauma. Nevertheless in the general donor pool the number of sclerosed glomeruli was no more than 12%. We did not meet at all in the whole volume of material any bi- opsy with the severe degree of arteriosclerosis. The «zero» biopsies of cadaver kidneys is quite usable and unexpensive tool to measure the degree of nephrosclerosis in order to exclude kidneys which are not fitable for transplantation. 

  20. Prognostic significance of repeat biopsy in lupus nephritis: Histopathologic worsening and a short time between biopsies is associated with significantly increased risk for end stage renal disease and death.

    Science.gov (United States)

    Arriens, Cristina; Chen, Sixia; Karp, David R; Saxena, Ramesh; Sambandam, Kamalanathan; Chakravarty, Eliza; James, Judith A; Merrill, Joan T

    2017-12-01

    Approximately half of patients with systemic lupus erythematosus (SLE) develop lupus nephritis (LN), a major cause of morbidity and early mortality in that disease. Prolonged renal inflammation is associated with irreversible kidney damage which confers a 30% risk of end stage renal disease (ESRD), making early, aggressive treatment mandatory. Failure to achieve therapeutic response or recurrence of renal flare often prompts repeat biopsy. However, the role of repeat biopsy in determining long-term renal prognosis remains controversial. For this reason repeat biopsies are usually not utilized unless clinical evidence of refractory or recurrent disease is already present, despite known mismatches between clinical and biopsy findings. The current study quantifies the degree to which histopathologic worsening between first and second biopsies and duration between them predicts ESRD and death. Medical records of 141 LN patients with more than one biopsy were obtained from a single large urban medical center. Cases were attained using billing codes for diagnosis and procedures from 1/1999-1/2015. Biopsy worsening was defined as unfavorable histopathologic classification transitions and/or increased chronicity; if neither were present, the patient was defined as non-worsening. We used Cox proportional hazard models to study the relationship between ESRD and survival adjusting for covariates which included age at first biopsy, gender, race, initial biopsy class, and initial induction therapy. Of 630 patients screened, 141 had more than one biopsy. Advancing chronicity was detected in 48 (34.0%) and a renal class switch to worse grade of pathology was found in 54 (38.3%). At least one of these adverse second biopsy features was reported in 79 (56.0%) patients. Five years following initial biopsy, 28 (35.4%) of those with worsening histopathology on second biopsy developed ESRD, compared to 6 (9.7%) of non-worsening patients and 10 (12.7%) of patients with worsening

  1. JC virus chromogenic in situ hybridization in brain biopsies from patients with and without PML.

    Science.gov (United States)

    Procop, Gary W; Beck, Rose C; Pettay, James D; Kohn, Debra J; Tuohy, Marion J; Yen-Lieberman, Belinda; Prayson, Richard A; Tubbs, Raymond R

    2006-06-01

    Progressive multifocal leukoencephalopathy (PML) is a demyelinating disease of the central nervous system caused by the JC polyoma virus. Electron microscopy and immunohistochemistry are the traditional methods of confirming the presence of the virus in brain biopsies from these patients. We studied the brain biopsies from 7 patients with PML and 6 patients without PML with chromogenic in situ hybridization (CISH) for the JC polyoma virus using a commercially available probe. The biopsies from the patients with the PML cases were proven to contain the JC polyoma virus by traditional and molecular methods. The CISH findings were compared with the known state of infection. All (7/7) of the biopsies from patients with PML were positive for the presence of polyoma virus by CISH, w