WorldWideScience

Sample records for biopsy specimens revealed

  1. Impact of specimen adequacy on the assessment of renal allograft biopsy specimens.

    Science.gov (United States)

    Cimen, S; Geldenhuys, L; Guler, S; Imamoglu, A; Molinari, M

    2016-01-01

    The Banff classification was introduced to achieve uniformity in the assessment of renal allograft biopsies. The primary aim of this study was to evaluate the impact of specimen adequacy on the Banff classification. All renal allograft biopsies obtained between July 2010 and June 2012 for suspicion of acute rejection were included. Pre-biopsy clinical data on suspected diagnosis and time from renal transplantation were provided to a nephropathologist who was blinded to the original pathological report. Second pathological readings were compared with the original to assess agreement stratified by specimen adequacy. Cohen's kappa test and Fisher's exact test were used for statistical analyses. Forty-nine specimens were reviewed. Among these specimens, 81.6% were classified as adequate, 6.12% as minimal, and 12.24% as unsatisfactory. The agreement analysis among the first and second readings revealed a kappa value of 0.97. Full agreement between readings was found in 75% of the adequate specimens, 66.7 and 50% for minimal and unsatisfactory specimens, respectively. There was no agreement between readings in 5% of the adequate specimens and 16.7% of the unsatisfactory specimens. For the entire sample full agreement was found in 71.4%, partial agreement in 20.4% and no agreement in 8.2% of the specimens. Statistical analysis using Fisher's exact test yielded a P value above 0.25 showing that - probably due to small sample size - the results were not statistically significant. Specimen adequacy may be a determinant of a diagnostic agreement in renal allograft specimen assessment. While additional studies including larger case numbers are required to further delineate the impact of specimen adequacy on the reliability of histopathological assessments, specimen quality must be considered during clinical decision making while dealing with biopsy reports based on minimal or unsatisfactory specimens.

  2. Gleason Score Correlation Between Prostate Biopsy and Radical Prostatectomy Specimens

    Directory of Open Access Journals (Sweden)

    Erdem Öztürk

    2018-04-01

    Full Text Available Objective: Prostate cancer is the most common malignancy in men and the second cause of cancer-related mortality. Prostate biopsy and the Gleason score guide treatment decisions in prostate cancer. Several studies have investigated the correlation between biopsy scores and radical prostatectomy specimen scores. We also evaluated the correlation of Gleason scores of these specimens in our patient series. Materials and Methods: We retrospectively reviewed the data of 468 men who were diagnosed with prostate cancer and underwent radical prostatectomy between 2008 and 2017. Patients’ age, prostate-specific antigen levels at diagnosis, and prostate biopsy and radical prostatectomy specimen Gleason scores were recorded. Upgrading and downgrading were defined as increase or decrease of Gleason score of radical prostate specimen compared to Gleason score of prostate biopsy. Results: A total of 442 men diagnosed with prostate cancer were included in the study. The mean age of the patients was 62.62±6.26 years (44-84 years and mean prostate specific antigen level was 9.01±6.84 ng/mL (1.09-49 ng/mL. Prostate biopsy Gleason score was 7 in 27 (6.1% men. Radical prostatectomy specimen Gleason score was 7 in 62 (14% men. Gleason correlation was highest in the 240 patients (71.6% with score <7 and was lowest in the 31 (38.75% patients with score =7. Conclusion: This study demonstrated that the discordance rate between Gleason scores of prostate biopsy and radical prostatectomy specimens was 35.7%.

  3. Histopathologic quality of prostate core biopsy specimens: comparison of an MR-compatible biopsy needle and a ferromagnetic biopsy needle used for ultrasound-guided prostate biopsy

    International Nuclear Information System (INIS)

    Franiel, T.; Hamm, B.; Beyersdorff, D.; Fritzsche, F.; Staack, A.; Rost, J.

    2006-01-01

    Purpose: The histopathologic quality of core biopsy specimens obtained via MRI-guided prostate biopsy using a 16G MR-compatible needle was compared to that of biopsies obtained via ultrasound-guided biopsy using a conventional 18G stainless steel biopsy needle. Material and Methods: A retrospective analysis was performed for a total of 247 transrectal prostate biopsy specimens obtained from 32 patients. A total of 117 tissue cores were obtained from 15 patients (PSA of 10.8 ng/ml, age 64 years) who underwent an MRI-guided prostate biopsy using a 16G (1.7 mm) MR-compatible biopsy needle made of titanium alloy. The remaining 130 tissue cores were obtained from 17 patients (PSA of 6.7 ng/ml, age 68 years) who underwent a transrectal ultrasound-guided prostate biopsy using an 18G (1.3 mm) ferromagnetic stainless steel biopsy needle. The length and width of the histologic sections prepared from the tissue cores were measured to calculate the area. The histopathologic quality of the specimens was assessed microscopically using tissue fragmentation, the presence of crush artifacts, and the overall assessability as criteria. Each of these features was assigned a score from 0 to 3. All 3 features contributed equally to the overall score which ranged from 0 (no tissue) to 9 (optimal quality). Results: The overall quality scores assigned to the biopsies obtained with a 16G MR-compatible needle and an 18G ferromagnetic needle can be considered to be equivalent to a mean difference between patient related median scores of the specimens of -0.05 (95% confidence interval [-0.46; 0.36]) and a given equivalence limit of 1. The MRI biopsies showed more tissue fragmentation (p=0.001) but fewer crush artifacts (p=0.022) while the assessability did not differ significantly between the two needle types (p=0.064). There was also no significant difference in the calculated areas of the tissue cores (p=0.236). According to the different calibers of the biopsy needles, the lengths (p=0

  4. Characterization of Cement Particles Found in Peri-implantitis-Affected Human Biopsy Specimens.

    Science.gov (United States)

    Burbano, Maria; Wilson, Thomas G; Valderrama, Pilar; Blansett, Jonathan; Wadhwani, Chandur P K; Choudhary, Pankaj K; Rodriguez, Lucas C; Rodrigues, Danieli C

    2015-01-01

    Peri-implantitis is a disease characterized by soft tissue inflammation and continued loss of supporting bone, which can result in implant failure. Peri-implantitis is a multifactorial disease, and one of its triggering factors may be the presence of excess cement in the soft tissues surrounding an implant. This descriptive study evaluated the composition of foreign particles from 36 human biopsy specimens with 19 specimens selected for analysis. The biopsy specimens were obtained from soft tissues affected by peri-implantitis around cement-retained implant crowns and compared with the elemental composition of commercial luting cement. Nineteen biopsy specimens were chosen for the comparison, and five test cements (TempBond, Telio, Premier Implant Cement, Intermediate Restorative Material, and Relyx) were analyzed using scanning electron microscopy equipped with energy dispersive x-ray spectroscopy. This enabled the identification of the chemical composition of foreign particles embedded in the tissue specimens and the composition of the five cements. Statistical analysis was conducted using classification trees to pair the particles present in each specimen with the known cements. The particles in each biopsy specimen could be associated with one of the commercial cements with a level of probability ranging between .79 and 1. TempBond particles were found in one biopsy specimen, Telio particles in seven, Premier Implant Cement particles in four, Relyx particles in four, and Intermediate Restorative Material particles in three. Particles found in human soft tissue biopsy specimens around implants affected by peri-implant disease were associated with five commercially available dental cements.

  5. Bone biopsy needles. Mechanical properties, needle design and specimen quality

    International Nuclear Information System (INIS)

    Keulers, Annika; Penzkofer, T.; Cunha-Cruz, V.C.; Bruners, P.; Helmholtz Inst. fuer biomedizinische Technik, Aachen; Braunschweig, T.; Schmitz-Rode, T.; Mahnken, A.; Helmholtz Inst. fuer biomedizinische Technik, Aachen

    2011-01-01

    To quantitatively analyze differences in mechanical properties, needle design including signs of wear, subjective handling and specimen quality of bone biopsy needles. Materials and Methods: In this study 19 different bone biopsy systems (total 38; 2 /type) were examined. With each biopsy needle five consecutive samples were obtained from vertebral bodies of swine. During puncture a force-torques sensor measured the mechanical properties and subjective handling was assessed. Before and after each biopsy the needles were investigated using a profile projector and signs of wear were recorded. Afterwards, a pathologist semi-quantitatively examined the specimen regarding sample quality. The overall evaluation considered mechanical properties, needle wear, subjective handling and sample quality. Differences were assessed for statistical significance using ANOVA and t-test. Results: Needle diameter (p = 0.003) as well as needle design (p = 0.008) affect the mechanical properties significantly. Franseen design is significantly superior to other needle designs. Besides, length reduction recorded by the profile projector, as a quality criterion showed notable distinctions in between the needle designs. Conclusion: Bone biopsy needles vary significantly in performance. Needle design has an important influence on mechanical properties, handling and specimen quality. Detailed knowledge of those parameters would improve selecting the appropriate bone biopsy needle. (orig.)

  6. Prevalence of mabDAS-1 positivity in biopsy specimens from the esophagogastric junction.

    Science.gov (United States)

    Rogge-Wolf, Claudia; Seldenrijk, Cornelis A; Das, Kiron M; Timmer, Robin; Breumelhof, Ronald; Smout, André J P M; Amenta, Peter S; Griffel, Louis H

    2002-12-01

    Intestinal metaplasia (IM) is a precursor for malignancies at the esophagogastric junction. A monoclonal antibody, mAbDAS-1, can probably identify cellular characteristics of IM before the appearance of goblet cells. The aim of this study was to examine the prevalence of mAbDAS-1 positivity in biopsies from the squamocolumnar junction (SCJ) and to correlate this positivity with the presence of IM and clinical findings. In 559 patients, reflux symptoms were scored, and the presence of reflux esophagitis and hiatus hernia was evaluated during endoscopy. Two biopsy specimens were obtained from the SCJ. In a subset of patients (n = 99), biopsies from the endoscopically defined cardiac region (2 cm distal to proximal margin of gastric folds) were available. Biopsy specimens were stained with hematoxylin and eosin, Alcian Blue, modified Giemsa, and mAbDAS-1. mAbDAS-1 positivity was observed in the SCJ biopsies of 201 of 486 (41.4%) patients without IM and in 64 of 73 (87.7%) patients with IM. Patients without IM but with antibody positivity showed similar histological characteristics as patients with IM at the SCJ. Biopsies of 123 of 559 patients (22%) revealed a columnar-cuboidal epithelium, which was found to be mAbDAS-1 positive in 64.2% (77 of 123). Tissue specimens from the cardiac region without IM stained positive in 14.2% (13 of 91), 12 of those also stained at the SCJ. In patients without IM, a high prevalence of mAbDAS-1 positivity was observed. Biopsies of these patients showed similar histological characteristics as patients with IM. Although not all patients exhibiting this reactivity may develop IM, mAbDAS-1 reactivity may help in the understanding of the histogenesis of IM at the SCJ.

  7. Tumor containing fragment number influences immunohistochemistry positive rate of HER2 in biopsy specimens of gastric cancer.

    Science.gov (United States)

    Xu, Chen; Liu, Yalan; Ge, Xiaowen; Jiang, Dongxian; Zhang, Ying; Ji, Yuan; Hou, Jun; Huang, Jie; Su, Jieakesu; Zeng, Haiying; Qin, Jing; Hou, Yingyong

    2017-05-26

    HER2 assessment in biopsy specimens of gastric cancer (GC) is challenging because of the intratumoral heterogeneity. False negative results may be get because of limited biopsy material. The aim of this study is to explore how tumor-containing fragment number and biopsy specimen number affect HER2 immunohistochemistry (IHC) positive rate. Eight hundred and ninety biopsy specimens and 459 paired resected specimens were collected. IHC staining of HER2 was performed. HER2 IHC positive (scored 3+) rate was compared based on tumor-containing fragment number, biopsy specimen number, average size and tumor tissue proportion of tumor-containing fragments. The positive predictability of biopsy specimens to resected specimens was analyzed based on tumor fragment number. HER2 IHC positive rates were 2.0, 3.5, 7.0, 13.2, 17.1, and 15.9% when tumor fragment numbers were 1, 2, 3, 4, 5 and 6 respectively. The rate rose with the increase of tumor fragment number (P = 0.004). ROC curve analysis showed that biopsy specimens exhibited positive predictability when tumor fragment number reached 3, but showed better performance when the number was ≥4 (P fragment number reached 4, no statistic differences were reached in either HER2 IHC positive rate or positive predictability with further increase of the number (P > 0.05). HER2 IHC positive rate was not associated with biopsy number (P = 0.127), average size of tumor fragments (P = 0.397), and tumor tissue proportion of tumor fragments (P = 0.825) directly. The number of tumor-containing fragments influences HER2 IHC positive (scored 3+) rate. Greater than or equal to 4 (≥4) tumor fragments give better results in the positive rate as well as positive predictability. We recommend the number of tumor containing fragments be described in the HER2 IHC pathology reports for clinical reference in endoscopic biopsy specimens of GC.

  8. Concordance of DNA methylation profiles between breast core biopsy and surgical excision specimens containing ductal carcinoma in situ (DCIS).

    Science.gov (United States)

    Chen, Youdinghuan; Marotti, Jonathan D; Jenson, Erik G; Onega, Tracy L; Johnson, Kevin C; Christensen, Brock C

    2017-08-01

    The utility and reliability of assessing molecular biomarkers for translational applications on pre-operative core biopsy specimens assume consistency of molecular profiles with larger surgical specimens. Whether DNA methylation in ductal carcinoma in situ (DCIS), measured in core biopsy and surgical specimens are similar, remains unclear. Here, we compared genome-scale DNA methylation measured in matched core biopsy and surgical specimens from DCIS, including specific DNA methylation biomarkers of subsequent invasive cancer. DNA was extracted from guided 2mm cores of formalin fixed paraffin embedded (FFPE) specimens, bisulfite-modified, and measured on the Illumina HumanMethylation450 BeadChip. DNA methylation profiles of core biopsies exhibited high concordance with matched surgical specimens. Within-subject variability in DNA methylation was significantly lower than between-subject variability (all Pcore biopsy and surgical specimens, 15%, and a pathway analysis of these CpGs indicated enrichment for genes related with wound healing. Our results indicate that DNA methylation measured in core biopsies are representative of the matched surgical specimens and suggest that DCIS biomarkers measured in core biopsies can inform clinical decision-making. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  9. Eosinophils in biopsy specimens of lichen sclerosus: a not uncommon finding.

    Science.gov (United States)

    Lester, Elizabeth B; Swick, Brian L

    2015-01-01

    Evolving lesions of lichen sclerosus (LS) pose a diagnostic challenge owing to an absence of classic findings of epidermal atrophy, dermal sclerosis, a band-like lymphocytic infiltrate and the presence of eosinophils. Retrospective specimens of LS were reviewed. Demographic information, biopsy vs. excision and the following histopathological characteristics were noted: presence and number of eosinophils, epidermal hyperplasia, spongiosis, early/transitional LS, well-developed LS and coexisting squamous cell carcinoma (SCC). Linear regression analysis was performed. The data consisted of 66 biopsies (36 male [M], 30 female [F]), from 53 individuals (33M, 20F), including 57 genital and 9 extragenital biopsies. Seven biopsies showed SCC, 28 showed epidermal hyperplasia and 14 exhibited spongiosis. Thirty-five specimens were early/transitional LS and commonly exhibited epidermal hyperplasia (57%), epidermotropism of lymphocytes (97%) and basement membrane thickening (97%). Thirty-five biopsies (53%) contained eosinophils (23 early/transitional lesions). Male gender (p = 0.074) was associated with increased eosinophils. The presence of SCC (p = 0.014) was a significant predictors of eosinophil number. Epidermal hyperplasia, epidermotropism of lymphocytes and basement membrane thickening are helpful features in identifying early LS. Eosinophils are not an uncommon finding in LS and are most common in male genital lesions and in LS associated with SCC. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  10. Image-Guided percutaneous biopsies with a biopsy gun

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kyung Hwan; Lim, Hyo Keun; Kim, Eun Ah; Yun, Ku Sub; Bae, Sang Hoo; Shin, Hyung Sik [Hallym University College of Medicine, Seoul (Korea, Republic of)

    1994-07-15

    We report the results of image-guided percutaneous biopsies with a biopsy gun and evaluate the clinical usefulness. One hundred and five biopsies under ultrasonographic or fluoroscopic guidance were performed. Various anatomic sites were targeted(liver; 50, chest; 22, kidney; 12, pancreas; 8, intraperitoeum; 7, retroperitoneum; ). Obtained tissue was diagnostic in 98 of the 105 biopsies(93%). In each instance, representative core tissue specimens were obtained. Evaluation of the core tissue by pathologist revealed consistent, uniform specimens that contained significant crush artifact in no case. Five biopsies yielded inadequate tissue which were too small for histopathologic interpretation or were composed of necrotic debris. Two biopsies yielded adequate tissues, but tissues were not of the target. The diagnoses were malignancy in 77 biopsies and benign disease in 21 biopsies. No complications other than mild, localized discomfort were encountered except a transient hemoptysis and pneumothorax which was observed in two patients. Cutting biopsy with a biopsy gun provided sufficient amount of target tissue for an accurate diagnosis of malignant and benign disease. It was a safe and useful procedure for percutaneous biopsy.

  11. Capillary Versus Aspiration Biopsy: Effect of Needle Size and Length on the Cytopathological Specimen Quality

    International Nuclear Information System (INIS)

    Hopper, Kenneth D.; Grenko, Ronald T.; Fisher, Alicia I.; TenHave, Thomas R.

    1996-01-01

    Purpose: To test the value of the nonaspiration, or capillary, biopsy technique by experimental comparison with the conventional fine-needle aspiration technique using various needle gauges and lengths. Methods: On fresh hepatic and renal tissue from five autopsies, multiple biopsy specimens were taken with 20, 22, and 23-gauge Chiba needles of 5, 10, 15, and 20-cm length, using the aspiration technique and the capillary technique. The resultant specimens were graded on the basis of a grading scheme by a cytopathologist who was blinded to the biopsy technique. Results: The capillary technique obtained less background blood or clot which could obscure diagnostic tissue, although not significantly different from the aspiration technique (p= 0.2). However, for the amount of cellular material obtained, retention of appropriate architecture, and mean score, the capillary technique performed statistically worse than aspiration biopsy (p < 0.01). In addition, with decreasing needle caliber (increasing needle gauge) and increasing length, the capillary biopsy was inferior to the aspiration biopsy. Conclusion: The capillary biopsy technique is inferior to the aspiration technique according to our study. When the capillary technique is to be applied, preference should be given to larger caliber, shorter needles

  12. The expressions of P53 protein and proliferating cell nuclear antigen in specimens by CT-guidance percutaneous lung biopsy

    International Nuclear Information System (INIS)

    Zhuang Yiping; Shen Zongli; Zhang Jin; Kang Zheng; Zhu Yueqing; Feng Yong; Shen Wenrong; Wang Yaping

    2004-01-01

    Objective: To evaluate relations between lung cancer and the expressions of P53 protein together with proliferating cell nuclear antigen (PCNA) in specimens of lung lesions by needle biopsy. Methods: CT-guidance percutaneous biopsy of lung lesions were performed in 66 patients with the determination of expressions of p53 protein and PCNA by flow cytometer (FCM). Results: 1. The sensitivity of CT-guidance percutaneous biopsy was 94.3% in 53 cases of lung cancer with the diagnostic accuracy of 90.9% totally. The complication rate of pneumothorax was 4.6%. 2. The expression of P53 protein was (29.9 ± 2.7)% in lung cancer (53 cases), while (17.9 ± 2.8)% in benign lesions (13 cases) (t=2.0, P 2 =6.10, P 2 =9.71, P 0.05). Conclusions: FCM plays and valuable role in determining the expression of P53 protein and PCNA in the specimen of lung cancer by CT-guided percutaneous biopsy. The expression of p53 and PCNA may be useful in the diagnosis of lung cancer by providing the relation between imaging of lung cancer and the molecular mechanism, and furthermore revealing the characteristics of molecular biology of lung cancer at protein level. (authors)

  13. Stellate-cell lipidosis in liver biopsy specimens. Recognition and significance.

    Science.gov (United States)

    Levine, Pascale Hummel; Delgado, Yara; Theise, Neil D; West, A Brian

    2003-02-01

    Hepatic stellate-cell lipidosis due to hypervitaminosis A can lead to cirrhosis, which can be averted by restricting vitamin A intake. Other causes, including the use of synthetic retinoids, have been postulated. We studied the frequency and etiology of stellate-cell lipidosis in patients undergoing liver biopsy for reasons other than vitamin A abuse. Fourteen cases (1.1%) were identified retrospectively among 1,235 nontransplant liver biopsy specimens examined from January 1995 through December 1999. Diagnostic criteria included the following: lipid-laden cells in the space of Disse; small, dark, crescent-shaped nuclei with inconspicuous nucleoli; and wispy cytoplasmic strands separating fat droplets. Patient details, reason for biopsy, and medication use were studied. Reasons for biopsy included hepatitis C (10 cases), abnormal liver enzyme levels (2 cases), methotrexate use (1 case), and alcohol abuse (1 case). Hypervitaminosis A was not suspected clinically in the 5 patients who used oral vitamin A or 3 who used topical tretinoin (Retin-A). In 6 patients, no cause of stellate-cell lipidosis was discerned. Stellate-cell lipidosis should be reported to alert clinicians to a potentially preventable form of liver injury.

  14. Breast cancer: determining the genetic profile from ultrasound-guided percutaneous biopsy specimens obtained during the diagnostic workups.

    Science.gov (United States)

    López Ruiz, J A; Zabalza Estévez, I; Mieza Arana, J A

    2016-01-01

    To evaluate the possibility of determining the genetic profile of primary malignant tumors of the breast from specimens obtained by ultrasound-guided percutaneous biopsies during the diagnostic imaging workup. This is a retrospective study in 13 consecutive patients diagnosed with invasive breast cancer by B-mode ultrasound-guided 12 G core needle biopsy. After clinical indication, the pathologist decided whether the paraffin block specimens seemed suitable (on the basis of tumor size, validity of the sample, and percentage of tumor cells) before sending them for genetic analysis with the MammaPrint® platform. The size of the tumors on ultrasound ranged from 0.6cm to 5cm. In 11 patients the preserved specimen was considered valid and suitable for use in determining the genetic profile. In 1 patient (with a 1cm tumor) the pathologist decided that it was necessary to repeat the core biopsy to obtain additional samples. In 1 patient (with a 5cm tumor) the specimen was not considered valid by the genetic laboratory. The percentage of tumor cells in the samples ranged from 60% to 70%. In 11/13 cases (84.62%) it was possible to do the genetic analysis on the previously diagnosed samples. In most cases, regardless of tumor size, it is possible to obtain the genetic profile from tissue specimens obtained with ultrasound-guided 12 G core biopsy preserved in paraffin blocks. Copyright © 2015 SERAM. Published by Elsevier España, S.L.U. All rights reserved.

  15. Patient identification error among prostate needle core biopsy specimens--are we ready for a DNA time-out?

    Science.gov (United States)

    Suba, Eric J; Pfeifer, John D; Raab, Stephen S

    2007-10-01

    Patient identification errors in surgical pathology often involve switches of prostate or breast needle core biopsy specimens among patients. We assessed strategies for decreasing the occurrence of these uncommon and yet potentially catastrophic events. Root cause analyses were performed following 3 cases of patient identification error involving prostate needle core biopsy specimens. Patient identification errors in surgical pathology result from slips and lapses of automatic human action that may occur at numerous steps during pre-laboratory, laboratory and post-laboratory work flow processes. Patient identification errors among prostate needle biopsies may be difficult to entirely prevent through the optimization of work flow processes. A DNA time-out, whereby DNA polymorphic microsatellite analysis is used to confirm patient identification before radiation therapy or radical surgery, may eliminate patient identification errors among needle biopsies.

  16. Contribution of flow cytometry to the diagnosis of gastric lymphomas in endoscopic biopsy specimens.

    Science.gov (United States)

    Almasri, N M; Zaer, F S; Iturraspe, J A; Braylan, R C

    1997-07-01

    Gastric lymphomas seem to have unique clinical, pathologic, and immunophenotypic features that set them apart from nodal lymphomas. Microscopic examination of endoscopic biopsy specimens is the most frequent procedure used to diagnose gastric tumors, but it is very difficult, and sometimes impossible, to recognize lymphomas in endoscopic samples by histologic or even immunohistologic methods. Because most gastric lymphomas are of B-cell origin, we used flow cytometry to assess B-cell clonality in gastric biopsy specimens containing dense lymphocytic infiltrates thought to represent lymphoma. We prepared viable cell suspensions from unfixed specimens obtained from 29 consecutive patients who had a previous microscopic diagnosis of suspicious gastric lymphoid infiltrates. We performed immunophenotypic studies with multicolor flow cytometry, and we assessed clonality by examination of immunoglobulin (Ig) light-chain expression analyzed exclusively on B cells identified by anti-CD20 or CD19 antibodies. The mean number of cells recovered was 1.04 x 10(6), from an average of 5.5 gastric biopsy fragments per patient. In 26 of the 29 patients, the number of cells was adequate for analysis. We detected B-cell monoclonality in 16 cases, including 5 in which the percentage of clonal B cells was less than 5%. Of the 16 cases, only 8 could be diagnosed as lymphomas on morphologic grounds alone; the remaining 8 patients had either suspicious lymphoid infiltrates or chronic gastritis. The three cases with an insufficient number of cells were considered non-neoplastic either on histologic grounds alone or in conjunction with Southern analysis of Ig genes. We conclude that flow cytometric immunophenotypic analysis of freshly prepared cell suspensions obtained from endoscopic biopsy specimens can be used to evaluate gastric lymphocytic infiltrates. Specifically, the analysis of surface Ig light-chain expression on B cells distinguishes between monoclonal (lymphoma) and polyclonal

  17. Is There a Concordance Between the Gleason Scores of Needle Biopsy and Radical Prostatectomy Specimens in Prostatic Carsinoma?

    Directory of Open Access Journals (Sweden)

    Faruk Özgör

    2016-03-01

    Full Text Available Aim: To evaluate the concordance between the Gleason Scores (GS of prostate biopsy and radical prostatectomy specimens. Methods: Prostate biopsy was performed in 1135 patients with the suspicion of prostate cancer in our clinic between 2008 and 2012. A total of 366 patients were diagnosed with prostate cancer. Radical prostatectomy was performed in 73 of these patients and GS of pathology specimens were included in this study for comparison. The patients were divided into three groups (low intermediate- and high-risk patients according to the D’amico risk classification for prostate cancer. Results: The median age of the patients was 64.2±6.1 years (54- 73. The mean prostate specific antigen level was 20.34 ng/mL and the mean biopsy core number was 12±0.58. A statistically significant concordance was detected between the GS of biopsy specimens and radical prostatectomy materials in 65.7% of patients (p<0.01. There were 40 patients in the low-risk group, however, 8 (20% of them were identified to be intermediate-risk patients and one (2.5% was found to be a high-risk patient after radical prostatectomy. Conclusion: Concordance between the GS of prostate biopsy and radical prostatectomy materials are important for selection of the appropriate treatment

  18. Techniques in human airway inflammation - Quantity and morphology of bronchial biopsy specimens taken by forceps of three sizes

    NARCIS (Netherlands)

    Aleva, RM; Kraan, J; Smith, M; ten Hacken, NHT; Postma, DS; Timens, W

    Background: In recent years, fiberoptic bronchoscopy has been introduced successfully in the research of bronchial asthma. Bronchial biopsy specimens obtained by this procedure are small, and an optimal biopsy technique is necessary to obtain high-quality tissue samples, as sufficient length of

  19. CT-Guided Transthoracic Core Biopsy for Pulmonary Tuberculosis: Diagnostic Value of the Histopathological Findings in the Specimen

    International Nuclear Information System (INIS)

    Fukuda, Hozumi; Ibukuro, Kenji; Tsukiyama, Toshitaka; Ishii, Rei

    2004-01-01

    We evaluated the value of CT-guided transthoracic core biopsy for the diagnosis of mycobacterial pulmonary nodules. The 30 subjects in this study had pulmonary nodules that had been either diagnosed histopathologically as tuberculosis or were suspected as tuberculosis based on a specimen obtained by CT-guided transthoracic core biopsy. The histopathological findings, the existence of acid-fast bacilli in the biopsy specimens, and the clinical course of the patients after the biopsy were reviewed retrospectively. Two of the three histological findings for tuberculosis that included epithelioid cells, multinucleated giant cells and caseous necrosis were observed in 21 of the nodules which were therefore diagnosed as histological tuberculosis. Six of these 21 nodules were positive for acid-fast bacilli, confirming the diagnosis of tuberculosis. Thirteen of the 21 nodules did not contain acid-fast bacilli but decreased in size in response to antituberculous treatment and were therefore diagnosed as clinical tuberculosis. Seven nodules with only caseous necrosis were diagnosed as suspected tuberculosis, with a final diagnosis of tuberculosis being made in 4 of the nodules and a diagnosis of old tuberculosis in 2 nodules. Two nodules with only multinucleated giant cells were diagnosed as suspected tuberculosis with 1 of these nodules being diagnosed finally as tuberculosis and the other nodule as a nonspecific granuloma. When any two of the three following histopathological findings - epithelioid cells, multinucleated giant cells or caseous necrosis - are observed in a specimen obtained by CT-guided transthoracic core biopsy, the diagnosis of tuberculosis can be established without the detection of acid-fast bacilli or Mycobacterium tuberculosis

  20. Pseudoangiomatous Stromal Hyperplasia in Core Needle Biopsies of Breast Specimens.

    Science.gov (United States)

    Kelten Talu, Canan; Boyaci, Ceren; Leblebici, Cem; Hacihasanoglu, Ezgi; Bozkurt, Erol Rustu

    2017-02-01

    Pseudoangiomatous stromal hyperplasia (PASH) is a benign lesion of myofibroblasts that is composed of a network of slit-like channels that resemble vascular spaces. The aims of this study were to document the frequency of PASH in core needle biopsy specimens (CNBS) of the breast, to describe which histopathologic findings coexist with PASH and to examine any endothelial cell differentiation. We reevaluated hematoxylin and eosin-stained sections of all CNBS that were obtained during a 1-year period. First, we performed CD34 and CD31 immunostainings to highlight the areas of PASH, then performed D2-40/podoplanin (lymphatic endothelial marker) and Fli-1 (vascular endothelial cell marker) immunostains. The total number of CNBS was 412. Areas of PASH were noted in 37 of the 412 cases (9%), with a mean age of 38.5 years. The lesions that were described in association with PASH were "benign breast parenchyma with stromal fibrosis" (17/37; 46%), "fibroepithelial tumors" (17/37; 46%), "columnar cell changes (CCC)" (2/37; 5%), and "invasive carcinoma" (1/37; 3%). There were 2 cases of CCC within the foci of PASH (direct contact with PASH), and 8 additional cases of CCC that coexisted in the same specimen but were not in direct contact. There was no staining for D2-40 or Fli-1 within PASH foci. PASH lesions occurred with a frequency of 9% in CNBS and were mostly in association with benign breast lesions in premenopausal women. CCC was determined as an accompanying epithelial lesion within or near PASH areas. No obvious immunopositivity compatible with endothelial cell differentiation was revealed.

  1. Routine Hematoxylin and Eosin Stain Is Specific for the Diagnosis of Cytomegalovirus Infection in Gastrointestinal Biopsy Specimens.

    Science.gov (United States)

    Guo, Ling; DeRoche, Tom C; Salih, Ziyan T; Qasem, Shadi A

    2018-03-01

    Gastrointestinal cytomegalovirus (CMV) infection is a serious complication in immunocompromised patients; clinicians often expect expedited results for biopsy specimens. Our goal is to determine the accuracy of identification of CMV on hematoxylin and eosin (H&E) stain. A total of 361 biopsy specimens from 273 patients with suspicion for CMV infection were retrieved. CMV was detected by immunohistochemistry (IHC) in 37 specimens acquired from 33 individual patients (average age = 54 years). Among the CMV-positive patients, 29 (88%) were reported to be immunosuppressed. Colon was the most common affected location. Of 37 CMV-positive specimens by IHC, 28 were positive by H&E (76%), 6 were negative (16%), and 3 were suspicious (8%). Of the 29 positive specimens on H&E, 28 were confirmed by IHC (97%) and 1 was indeterminate (3%). The sensitivity and specificity of H&E were 84% and 94%, respectively; the positive predictive value was 97%, and the negative predictive value was 93% ( P < .00001). Our results show that a preliminary diagnosis of CMV infection, based on H&E stains, can be reported with high specificity and low risk for false-positive results. Suspicious cases should be deferred pending the result of IHC stains.

  2. Ga-68 DOTATOC PET/CT-Guided Biopsy and Cryoablation with Autoradiography of Biopsy Specimen for Treatment of Tumor-Induced Osteomalacia

    Energy Technology Data Exchange (ETDEWEB)

    Maybody, Majid, E-mail: maybodym@mskcc.org [Memorial Sloan Kettering Cancer Center, Interventional Radiology Service (United States); Grewal, Ravinder K. [Memorial Sloan Kettering Cancer Center, Molecular Imaging and Therapy Service, Department of Radiology (United States); Healey, John H. [Memorial Sloan Kettering Cancer Center, Orthopedic Surgical Oncology Service, Department of Surgery (United States); Antonescu, Cristina R. [Memorial Sloan Kettering Cancer Center, Department of Pathology (United States); Fanchon, Louise [Memorial Sloan Kettering Cancer Center, Department of Physics (United States); Hwang, Sinchun [Memorial Sloan Kettering Cancer Center, Department of Radiology (United States); Carrasquillo, Jorge A. [Memorial Sloan Kettering Cancer Center, Molecular Imaging and Therapy Service, Department of Radiology (United States); Kirov, Assen [Memorial Sloan Kettering Cancer Center, Department of Physics (United States); Farooki, Azeez [Memorial Sloan Kettering Cancer Center, Department of Medicine (United States)

    2016-09-15

    Tumor-induced osteomalacia (TIO) is a rare paraneoplastic syndrome caused by small benign tumors of mesenchymal origin also known as phosphaturic mesenchymal tumors mixed connective tissue variant. Excellent prognosis is expected with eradication of the culprit tumor. These small tumors are notoriously difficult to localize with conventional imaging studies; this often leads to an extensive work up and prolonged morbidity. We report a patient with clinical diagnosis of TIO whose culprit tumor was localized with Ga-68 DOTATOC PET/CT and MRI. Biopsy and cryoablation were performed under Ga-68 DOTATOC PET/CT guidance. Autoradiography of the biopsy specimen was performed and showed in situ correlation between Ga-68 DOTATOC uptake and histopathology with millimeter resolution.

  3. Intratumor microvessel density in biopsy specimens predicts local response of hypopharyngeal cancer to radiotherapy

    International Nuclear Information System (INIS)

    Zhang, Shi-Chuan; Miyamoto, Shin-ichi; Hasebe, Takahiro; Ishii, Genichiro; Ochiai, Atsushi; Kamijo, Tomoyuki; Hayashi, Ryuichi; Fukayama, Masashi

    2003-01-01

    The aim of this retrospective study was to identify reliable predictive factors for local control of hypopharyngeal cancer (HPC) treated by radiotherapy. A cohort of 38 patients with HPC treated by radical radiotherapy at the National Cancer Center Hospital East between 1992 and 1999 were selected as subjects for the present study. Paraffin-embedded pre-therapy biopsy specimens from these patients were used for immunostaining to evaluate the relationships between local tumor control and expression of the following previously reported predictive factors for local recurrence of head and neck cancer treated by radiotherapy: Ki-67, Cyclin D1, CDC25B, VEGF, p53, Bax and Bcl-2. The predictive power of microvessel density (MVD) in biopsy specimens and of clinicopathologic factors (age, gender and clinical tumor-node-metastasis stage) was also statistically analyzed. Twenty-five patients developed tumor recurrence at the primary site. Univariate analysis indicated better local control of tumors with high microvessel density [MVD≥median (39 vessels/field)] than with low MVD (< median, P=0.042). There were no significant associations between local control and expression of Ki-67 (P=0.467), Bcl-2 (P=0.127), Bax (P=0.242), p53 (P=0.262), Cyclin D1 (P=0.245), CDC25B (P=0.511) or VEGF (P=0.496). Clinicopathologic factors were also demonstrated to have no significant influence on local control (age, P=0.974; gender, P=0.372; T factor, P=0.602; N factor, P=0.530; Stage, P=0.499). MVD in biopsy specimens was closely correlated with local control of HPC treated by radiotherapy. (author)

  4. Risk Factors Associated with Discordant Ki-67 Levels between Preoperative Biopsy and Postoperative Surgical Specimens in Breast Cancers.

    Directory of Open Access Journals (Sweden)

    Hyung Sun Kim

    Full Text Available The Ki-67 labelling index is significant for the management of breast cancer. However, the concordance of Ki-67 expression between preoperative biopsy and postoperative surgical specimens has not been well evaluated. This study aimed to find the correlation in Ki-67 expression between biopsy and surgical specimens and to determine the clinicopathological risk factors associated with discordant values.Ki-67 levels were immunohistochemically measured using paired biopsy and surgical specimens in 310 breast cancer patients between 2008 and 2013. ΔKi-67 was calculated by postoperative Ki-67 minus preoperative levels. The outliers of ΔKi-67 were defined as [lower quartile of ΔKi-67-1.5 × interquartile range (IQR] or (upper quartile + 1.5 × IQR and were evaluated according to clinicopathological parameters by logistic regression analysis.The median preoperative and postoperative Ki-67 levels were 10 (IQR, 15 and 10 (IQR, 25, respectively. Correlation of Ki-67 levels between the two specimens indicated a moderately positive relationship (coefficient = 0.676. Of 310 patients, 44 (14.2% showed outliers of ΔKi-67 (range, ≤-20 or ≥28. A significant association with poor prognostic factors was found among these patients. Multivariate analysis determined that significant risk factors for outliers of ΔKi-67 were tumor size >1 cm, negative progesterone receptor (PR expression, grade III cancer, and age ≤35 years. Among 171 patients with luminal human epidermal growth factor receptor 2-negative tumors, breast cancer subtype according to preoperative or postoperative Ki-67 levels discordantly changed in 46 (26.9% patients and a significant proportion of patients with discordant cases had ≥1 risk factor.Ki-67 expression showed a substantial concordance between biopsy and surgical specimens. Extremely discordant Ki-67 levels may be associated with aggressive tumor biology. In patients with luminal subtype disease, clinical application of Ki-67

  5. Multi-institutional Evaluation of Upper Urinary Tract Biopsy Using Backloaded Cup Biopsy Forceps, a Nitinol Basket, and Standard Cup Biopsy Forceps.

    Science.gov (United States)

    Lama, Daniel J; Safiullah, Shoaib; Patel, Roshan M; Lee, Thomas K; Balani, Jyoti P; Zhang, Lishi; Okhunov, Zhamshid; Margulis, Vitaly; Savage, Stephen J; Uchio, Edward; Landman, Jaime

    2018-04-06

    To compare the performance of 3 contemporary ureteroscopic biopsy devices for the histopathologic diagnosis of upper tract urothelial carcinoma (UTUC). We retrospectively reviewed 145 patients who underwent 182 urothelial biopsies using 2.4F backloaded cup biopsy forceps, a nitinol basket, or 3F standard cup biopsy forceps at 3 tertiary academic centers between 2011 and 2016. Experienced genitourinary pathologists provided an assessment of each specimen without knowledge of the device used for biopsy. For patients who underwent nephroureterectomy without neoadjuvant chemotherapy within 3 months of biopsy-proven UTUC diagnosis, the biopsy grade was compared with both the grade and stage of the surgical specimen. Biopsy utilization varied among the 3 institutions (P cup forceps was rated similarly to the nitinol basket (P >.05) and was favored over standard cup forceps specimens. Grade concordance was not affected by specimen size (P >.05), morphology (P >.1), or location (P >.5). No difference existed among the devices in the rate of acquiring a grade concordant biopsy; however, the backloaded cup forceps provided concordant biopsies that could be distinguished as low- and high-grade (P = .02). The backloaded cup forceps and nitinol basket obtained a higher quality urothelial specimen compared with standard cup forceps. Ureteroscopic biopsy device selection did not significantly impact the accuracy of the histologic diagnosis of UTUC. Copyright © 2018 Elsevier Inc. All rights reserved.

  6. Assessment of bone biopsy needles for sample size, specimen quality and ease of use

    International Nuclear Information System (INIS)

    Roberts, C.C.; Liu, P.T.; Morrison, W.B.; Leslie, K.O.; Carrino, J.A.; Lozevski, J.L.

    2005-01-01

    To assess whether there are significant differences in ease of use and quality of samples among several bone biopsy needles currently available. Eight commonly used, commercially available bone biopsy needles of different gauges were evaluated. Each needle was used to obtain five consecutive samples from a lamb lumbar pedicle. Subjective assessment of ease of needle use, ease of sample removal from the needle and sample quality, before and after fixation, was graded on a 5-point scale. The number of attempts necessary to reach a 1 cm depth was recorded. Each biopsy specimen was measured in the gross state and after fixation. The RADI Bonopty 15 g and Kendall Monoject J-type 11 g needles were rated the easiest to use, while the Parallax Core-Assure 11 g and the Bard Ostycut 16 g were rated the most difficult. Parallax Core-Assure and Kendall Monoject needles had the highest quality specimen in the gross state; Cook Elson/Ackerman 14 g and Bard Ostycut 16 g needles yielded the lowest. The MD Tech without Trap-Lok 11 g needle had the highest quality core after fixation, while the Bard Ostycut 16 g had the lowest. There was a significant difference in pre-fixation sample length between needles (P<0.0001), despite acquiring all cores to a standard 1 cm depth. Core length and width decrease in size by an average of 28% and 42% after fixation. Bone biopsy needles vary significantly in performance. Detailed knowledge of the strengths and weaknesses of different needles is important to make an appropriate selection for each individual's practice. (orig.)

  7. Banff study of pathologic changes in lung allograft biopsy specimens with donor-specific antibodies

    DEFF Research Database (Denmark)

    Wallace, William Dean; Li, Ning; Andersen, Claus B

    2016-01-01

    a statistically significant difference vs NABs in the setting of acute lung injury, with or without diffuse alveolar damage (p = 0.0008), in the presence of capillary neutrophilic inflammation (p = 0.0014), and in samples with endotheliitis (p = 0.0155). In samples with complement 4d staining, there was a trend......-DSAs, and no antibodies (NABs) present. The significance of each histologic variable was reviewed. RESULTS: We found no statistically significant association with acute cellular rejection, airway inflammation, or bronchiolitis obliterans and the presence or absence of antibodies. However, biopsy specimens with DSAs had...... but no statistically significant difference between specimens associated with DSAs and specimens with NABs. CONCLUSIONS: Capillary inflammation, acute lung injury, and endotheliitis significantly correlated with DSAs. The infrequently observed diffuse staining for complement 4d limits the usefulness of this stain....

  8. Study of CT-guided percutaneous biopsy for the spine lesions

    International Nuclear Information System (INIS)

    Zhang Ji; Wu Chungen; Cheng Yongde; Zhu Xuee; Gu Yifeng; Zhang Huijian

    2008-01-01

    Objective: To determine the successful rate, diagnostic accuracy and clinical usefulness of CT-guided percutaneous biopsy for the spine lesions. Methods: Eight-five patients (61 outpatients, 24 ward patients)underwent CT-guided percutaneous biopsy for the spine lesion. The imaging appearance of spinal lesions were lytic in 57 cases, osteosclerotic in 19 cases, and mixed in 9 cases. Biopsy specimens were sent for cytologic and histologic analysis in order to correct diagnosis. Bacterial studies were performed when ever infection was suspected. Results: The localization of puncture biopsy needle inside the spinal lesions, was conformed by computed tomography including 3 cervical, 26 thoracic, 37 lumbar, and 19 sacral lesions. Biopsy specimens included bone (29 cases), soft tissue (5 cases), mixed tissue (47 cases )and no specimen be obtained(4 cases). An adequate specimen for pathologic examination was obtained in 81 biopsies (95%). The pathologic examinations revealed 44 metastases, 17 primary bone neoplasms, 18 infections (included tuberculosis)and 2 normal tissues of vertebral body. The diagnostic accuracy reached 97.5% (79 of 81 patients). Conclusions: CT-guided percutaneous biopsy is an important tool in the evaluation of spinal lesions, providing accurate localization, less trauma and reliable pathologic diagnosis and worthwhile to be the routine before vertebroplasy. (authors)

  9. Instant Transport Media for Biopsied Soft Tissue Specimens: A Comparative Study

    Directory of Open Access Journals (Sweden)

    Shankargouda Patil

    2015-01-01

    Full Text Available Background. Formalin, a traditionally preferred fixative in the field of pathology, has restricted usage in private settings. Since its toxicity violates the Occupational Safety and Health Administration regulations, an eco-friendly alternative would be the need of the hour. Hence an instant media which is economical and nontoxic and enables easy transport of biopsied soft tissue specimens in its original state is of vital importance. Materials and Methods. Commercially available fresh goat buccal mucosa specimens were sliced into smaller bits of equal dimensions and placed in six different containers containing 20% honey, 30% jaggery, milk, and ice for 1 hr, 6 hours, 12 hours, and 24 hours each with formalin as a positive control. After the set time interval, the specimens were fixed in 10% buffered formalin for 24 hours followed by routine processing and staining. The histologic interpretations were a blinded procedure and evaluated by two experts. Results were statistically analysed. Results. 30% jaggery proved to be an ideal transport media showing high quality preservation after 24 hours. 20% honey and ice showed optimal tissue preservation up to 6 hours following which quality deteriorated. Tissues transported in milk showed poor preservation. Conclusion. 30% jaggery can be endorsed in routine histopathological analysis as a transport media.

  10. The effectiveness of inking needle core prostate biopsies for preventing patient specimen identification errors: a technique to address Joint Commission patient safety goals in specialty laboratories.

    Science.gov (United States)

    Raff, Lester J; Engel, George; Beck, Kenneth R; O'Brien, Andrea S; Bauer, Meagan E

    2009-02-01

    The elimination or reduction of medical errors has been a main focus of health care enterprises in the United States since the year 2000. Elimination of errors in patient and specimen identification is a key component of this focus and is the number one goal in the Joint Commission's 2008 National Patient Safety Goals Laboratory Services Program. To evaluate the effectiveness of using permanent inks to maintain specimen identity in sequentially submitted prostate needle biopsies. For a 12-month period, a grossing technician stained each prostate core with permanent ink developed for inking of pathology specimens. A different color was used for each patient, with all the prostate cores from all vials for a particular patient inked with the same color. Five colors were used sequentially: green, blue, yellow, orange, and black. The ink was diluted with distilled water to a consistency that allowed application of a thin, uniform coating of ink along the edges of the prostate core. The time required to ink patient specimens comprising different numbers of vials and prostate biopsies was timed. The number and type of inked specimen discrepancies were evaluated. The identified discrepancy rate for prostate biopsy patients was 0.13%. The discrepancy rate in terms of total number of prostate blocks was 0.014%. Diluted inks adhered to biopsy contours throughout tissue processing. The tissue showed no untoward reactions to the inks. Inking did not affect staining (histochemical or immunohistochemical) or pathologic evaluation. On average, inking prostate needle biopsies increases grossing time by 20%. Inking of all prostate core biopsies with colored inks, in sequential order, is an aid in maintaining specimen identity. It is a simple and effective method of addressing Joint Commission patient safety goals by maintaining specimen identity during processing of similar types of gross specimens. This technique may be applicable in other specialty laboratories and high

  11. Histopathologic Review of Previously Negative Prostatic Core Needle Biopsies following a New Diagnosis of Adenocarcinoma of the Prostate by Core Needle Biopsies: Implications for Quality Assurance Programs

    Directory of Open Access Journals (Sweden)

    Jay Patel

    2008-01-01

    Full Text Available Programs for quality assurance are increasingly important in surgical pathology. Many quality assurance (QA techniques for surgical pathology were adopted from procedures introduced in cytopathology. Surgical pathology specimens have diminished in size such that the majority of diagnostic biopsies of prostatic lesions are now core needle biopsies. These specimens raise issues similar to those of cytology specimens, including concerns regarding adequacy and the representative nature of the biopsy. Due to sample size, some neoplasms may not be diagnosed on initial biopsy, raising concerns regarding false negative results. Cytopathologists have instituted QA procedures including review of all previously negative slides received within five years prior to the new diagnosis of high grade squamous intraepithelial lesion or gynecologic malignancy. No such requirement exists in surgical pathology for review of core biopsies. The Department of Pathology at the University of Utah instituted a QA policy requiring review of prior negative prostatic needle biopsies following a new diagnosis of prostatic adenocarcinoma. We reviewed five years of QA records of prostate needle biopsy review. During this time, nine hundred and fifty-eight core biopsy sets were performed. Two hundred and ninety-five of these contained at least one biopsy with a diagnosis of adenocarcinoma. Two hundred and eight patients had a prior set of prostatic needle biopsies with a diagnosis of adenocarcinoma. The remaining 87 had prior biopsies with either a diagnosis of prostatic intraepithelial neoplasia (23, small atypical acinar proliferation (21 or no evidence of malignancy (43. QA review of these 87 cases revealed two biopsies which revealed foci of adenocarcinoma. Both had been initially diagnosed as no evidence of malignancy. The false negative rate for core biopsy was 0.68%. In an additional twenty-one cases, microscopic foci of atypical small acinar proliferations were found in

  12. Yield of abrams needle pleural biopsy in exudative pleural effusion

    International Nuclear Information System (INIS)

    Khan, I.N.; Zaman, M.; Khan, N.; Jadoon, H.; Ahmed, A.

    2009-01-01

    Pleural effusion is the abnormal collection of fluid in the pleural space resulting from excessive fluid production or decreased absorption and it is one of the most common clinical conditions that we come across in pulmonology clinics and in hospitals. The objective of prospective study was to evaluate the diagnostic role of Abrams Needle Biopsy in Exudative Pleural Effusion The study was performed at the Department of Pulmonology, Ayub Teaching Hospital, Abbottabad over a period of 1 year, i.e., January 2008 to December 2008. Sixty-three patients of either sex and all ages with exudative pleural effusion, on whom Abrams Needle Biopsy was performed were included in the study. Minimum of four specimens from each patient were taken and histopathology done. Out of 63 patients, histopathology revealed the cause in 60 (95%) cases. Tuberculosis, malignancy and rheumatoid pleurisy were confirmed in 34, 24, and 2 cases respectively. Specimens of 3 patients did not reveal any result and showed non-specific inflammation and were further investigated accordingly. The diagnostic yield of Biopsy was 95%. Pleural biopsy is still a reliable and valuable investigation in diagnosing pleural effusion, provided that adequate pleural specimen is taken. (author)

  13. High concordance of findings obtained from transgluteal magnetic resonance imaging - and transrectal ultrasonography-guided biopsy as compared with prostatectomy specimens.

    Science.gov (United States)

    Steurer, Stefan; Rico, Sebastian Dwertmann; Simon, Ronald; Minner, Sarah; Tsourlakis, Maria Christina; Krech, Till; Koop, Christina; Graefen, Markus; Heinzer, Hans; Adam, Meike; Huland, Hartwig; Schlomm, Thorsten; Sauter, Guido; Lumiani, Agron

    2017-09-01

    To determine the utility of our transgluteal magnetic resonance imaging (MRI)-guided prostate biopsy approach. A total of 960 biopsy series, taken within the period of 1 year, were evaluated, including 301 MRI-guided and 659 transrectal ultrasonography (TRUS)-guided biopsies. The positivity rate and proportion of high grade cancers were significantly higher in MRI-guided than in TRUS-guided biopsies. Of 301 MRI-guided biopsies, 65.4% contained cancer while 57.2% of 659 TRUS biopsies contained cancer (P = 0.016). Gleason grade 3 + 3 = 6 disease was observed in 16.8% of 197 MRI-guided and in 36.1% of 377 TRUS-guided biopsies (P guided biopsies. In all cancers, the mean cancer surface area was 64.8 ± 51.6 mm 2 in MRI-guided biopsies as compared with 23.0 ± 31.4 mm 2 in non-MRI-guided biopsies (P guided biopsy was highest in Gleason grade 3 + 3 = 6 cancers (20.9 ± 27.9 vs 5.1 ± 10.2 mm 2 ; P guided and in 170 patients with non-MRI-guided biopsies. This comparison showed a very high but almost identical concordance of TRUS- and MRI-guided biopsies with the prostatectomy specimen findings. With both approaches, undetected high-risk cancers were present in ~10% of patients with low-risk biopsy results. A significant difference was observed, however, in the proportion of patients who had clinically insignificant cancers and who underwent surgery. The proportion of patients with Gleason grade 3 + 3 = 6 carcinoma in their prostatectomy specimen was 11.2% in the post-TRUS biopsy cohort, but only 2.5% in the post-MRI biopsy cohort (P = 0.021). MRI-guided transgluteal prostate biopsy has a high detection rate for high-risk carcinomas, while the risk of detecting clinically insignificant carcinomas appears to be reduced. This may by itself lead to a reduction of unnecessary prostatectomies. Overtreatment may be further avoided by better applicability of molecular testing to MRI-guided biopsies because of the excessive amount of tissue available for analysis, especially in

  14. Usefulness of automated biopsy guns in image-guided biopsy

    International Nuclear Information System (INIS)

    Lee, Jung Hyung; Rhee, Chang Soo; Lee, Sung Moon; Kim, Hong; Woo, Sung Ku; Suh, Soo Jhi

    1994-01-01

    To evaluate the usefulness of automated biopsy guns in image-guided biopsy of lung, liver, pancreas and other organs. Using automated biopsy devices, 160 biopsies of variable anatomic sites were performed: Biopsies were performed under ultrasonographic(US) guidance in 95 and computed tomographic (CT) guidance in 65. We retrospectively analyzed histologic results and complications. Specimens were adequate for histopathologic diagnosis in 143 of the 160 patients(89.4%)-Diagnostic tissue was obtained in 130 (81.3%), suggestive tissue obtained in 13(8.1%), and non-diagnostic tissue was obtained in 14(8.7%). Inadequate tissue was obtained in only 3(1.9%). There was no statistically significant difference between US-guided and CT-guided percutaneous biopsy. There was no occurrence of significant complication. We have experienced mild complications in only 5 patients-2 hematuria and 2 hematochezia in transrectal prostatic biopsy, and 1 minimal pneumothorax in CT-guided percutaneous lung biopsy. All of them were resolved spontaneously. The image-guided biopsy using the automated biopsy gun was a simple, safe and accurate method of obtaining adequate specimen for the histopathologic diagnosis

  15. Usefulness of automated biopsy guns in image-guided biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jung Hyung; Rhee, Chang Soo; Lee, Sung Moon; Kim, Hong; Woo, Sung Ku; Suh, Soo Jhi [School of Medicine, Keimyung University, Daegu (Korea, Republic of)

    1994-12-15

    To evaluate the usefulness of automated biopsy guns in image-guided biopsy of lung, liver, pancreas and other organs. Using automated biopsy devices, 160 biopsies of variable anatomic sites were performed: Biopsies were performed under ultrasonographic(US) guidance in 95 and computed tomographic (CT) guidance in 65. We retrospectively analyzed histologic results and complications. Specimens were adequate for histopathologic diagnosis in 143 of the 160 patients(89.4%)-Diagnostic tissue was obtained in 130 (81.3%), suggestive tissue obtained in 13(8.1%), and non-diagnostic tissue was obtained in 14(8.7%). Inadequate tissue was obtained in only 3(1.9%). There was no statistically significant difference between US-guided and CT-guided percutaneous biopsy. There was no occurrence of significant complication. We have experienced mild complications in only 5 patients-2 hematuria and 2 hematochezia in transrectal prostatic biopsy, and 1 minimal pneumothorax in CT-guided percutaneous lung biopsy. All of them were resolved spontaneously. The image-guided biopsy using the automated biopsy gun was a simple, safe and accurate method of obtaining adequate specimen for the histopathologic diagnosis.

  16. SU-F-J-07: Evaluating the Adequacy of Biopsy Specimens for Genetic Signature Assessment by Measuring the Metabolic Activity in Specimens Obtained Under 18F-FDG PET/CT Guidance

    Energy Technology Data Exchange (ETDEWEB)

    Fanchon, L; Russell, J; Dogan, S; Carlin, S; Pinker-Domenig, K; Yorke, E; Schmidtlein, C. Ross; Fujisawa, S; Manova-Todorova, K; Zanzonico, P; Deasy, J O; Humm, J L; Solomon, S; Kirov, A S [Memorial Sloan Kettering Cancer Center, New York, NY (United States)

    2016-06-15

    Purpose: Genetic profiling of biopsied tissue is the basis for personalized cancer therapy. However biopsied materials may not contain sufficient amounts of DNA needed for analysis. We propose a method to determine the adequacy of specimens for performing genetic profiling by quantifying metabolic activity. Methods: We measured the response of two radiation detectors to the activity contained in the minimum amount of tumor cells needed for genetic profiling in biopsy specimens obtained under 2-deoxy-2-({sup 18}F)fluoro-D-glucose ({sup 18}F-FDG) PET/CT guidance. The expected tumor cell concentration in biopsy specimens was evaluated from the amount of DNA needed (∼100 µg) and the number of pathology sections typically used for the analysis. The average {sup 18}F-FDG uptake per cell was measured by incubating KPC-4662 pancreatic tumor cells and HT-29 colorectal adenocarcinoma tumor cells in {sup 18}F-FDG containing solution (activity concentrations between 0.0122 and 1.51 MBq/mL and glucose concentrations of 3.1 and 1 g/L) for 1 to 1.75 hours and then measuring the activity of a known number of cells. Measurements of surrogate specimens obtained using 18G needle biopsies of gels containing these cells in expected concentrations (∼10{sup 4} µL{sup −1}) were performed using an autoradiography CCD based device (up to 20 min exposure) and a scintillation well counter (∼1 min measurements) about 3 and 5 hours after the end of incubation respectively. Results: At start of autoradiography there were between 0.16 and 1.5 {sup 18}F-FDG molecules/cell and between 1.14 and 5.43×10{sup 7} {sup 18}F-FDG molecules/mL. For the scintillation well counter, sample to minimum-detectable-count rate ratios were greater than 7 and the counting error was less than 25% for ≤80 s measurement times. Images of the samples were identifiable on the autoradiograph for ∼10 min and longer exposure times. Conclusion: Scintillation well counter measurements and CCD based

  17. Infiltration of tumour-associated macrophages in prostate biopsy specimens is predictive of disease progression after hormonal therapy for prostate cancer.

    Science.gov (United States)

    Nonomura, Norio; Takayama, Hitoshi; Nakayama, Masashi; Nakai, Yasutomo; Kawashima, Atsunari; Mukai, Masatoshi; Nagahara, Akira; Aozasa, Katsuyuki; Tsujimura, Akira

    2011-06-01

    • To evaluate tumour-associated macrophage (TAM) infiltration in prostate biopsy specimens as a possible prognostic factor for prostate cancer (PCa) after hormonal therapy. • Immunostaining of TAMs in prostate biopsy specimens was performed using a monoclonal antibody CD68 for 71 patients having PCa treated with hormonal therapy. • Six microscopic (×400) fields around the cancer foci were selected for TAM counting. • The median value of serum prostate-specific antigen (PSA) was 50.1 ng/mL, and the median TAM count was 22. • Recurrence-free survival was significantly better in patients with fewer TAMs (<22) than in those with higher numbers of TAMs (≥22) (P < 0.001). • TAM count was higher in those with higher serum PSA (PSA), higher Gleason score, clinical T stage or those with PSA failure. Cox multivariate analysis showed that TAM count is one of the prognostic factors for PCa treated by hormonal therapy (P < 0.0001). • TAM infiltration in prostate needle biopsy specimens is a useful predictive factor for PSA failure or progression of PCa after hormonal therapy. © 2010 THE AUTHORS. BJU INTERNATIONAL © 2010 BJU INTERNATIONAL.

  18. Stereological quantification of immune-competent cells in baseline biopsy specimens from achilles tendons

    DEFF Research Database (Denmark)

    Kragsnaes, Maja Skov; Fredberg, Ulrich; Stribolt, Katrine

    2014-01-01

    BACKGROUND: Limited data exist on the presence and function of immune-competent cells in chronic tendinopathic tendons and their potential role in inflammation and tissue healing as well as in predicting long-term outcome. PURPOSE: To quantify subtypes of immune-competent cells in biopsy specimens...... immunohistochemically by quantifying the presence of macrophages (CD68-PGM1(+), CD68-KP1(+)), hemosiderophages (Perls blue), T lymphocytes (CD2(+), CD3(+), CD4(+), CD7(+), CD8(+)), B lymphocytes (CD20(+)), natural killer cells (CD56(+)), mast cells (NaSDCl(+)), Schwann cells (S100(+)), and endothelial cells (CD34......(+)) using a stereological technique. A follow-up examination was conducted more than 4 years (range, 4-9 years) after the biopsy procedure to evaluate the long-term presence of Achilles tendon symptoms. RESULTS: Macrophages, T lymphocytes, mast cells, and natural killer cells were observed in the majority...

  19. Computed Tomography-Guided Core-Needle Biopsy Specimens Demonstrate Epidermal Growth Factor Receptor Mutations in Patients with Non-Small-Cell Lung Cancer

    International Nuclear Information System (INIS)

    Chen, C.M.; Chang, J.W.C.; Cheung, Y.C.; Lin, G.; Hsieh, J.J.; Hsu, T.; Huang, S.F.

    2008-01-01

    Background: Target therapy with a new class of epidermal growth factor receptor (EGFR) inhibitors shows improved clinical response in EGFR gene-mutated lung cancers. Purpose: To evaluate the use of computed tomography (CT)-guided core-needle biopsy specimens for the assessment of EGFR gene mutation in non-small-cell lung cancer (NSCLC). Material and Methods: Seventeen (nine males, eight females) patients with advanced NSCLC were enrolled in this study. All patients underwent CT-guided core-needle biopsy of the lung tumor prior to treatment with the EGFR inhibitor gefitinib. There were no life-threatening complications of biopsy. The specimens were sent fresh-frozen for EGFR mutation analysis and histopathological study. Results: There were 12 (70.6%) EGFR gene mutants and five (29.4%) nonmutants. The objective response rate to gefitinib therapy was 73.3% (11 of 15 patients), with 91.7% (11 of 12 mutants) for the mutant group and 0% for the nonmutant group. Conclusion: CT-guided core-needle biopsy of advanced NSCLC enables the acquisition of sufficient tissue for EGFR gene mutation analysis

  20. HER2 testing on core needle biopsy specimens from primary breast cancers: interobserver reproducibility and concordance with surgically resected specimens

    International Nuclear Information System (INIS)

    Tsuda, Hitoshi; Kurosumi, Masafumi; Umemura, Shinobu; Yamamoto, Sohei; Kobayashi, Takayuki; Osamura, Robert Yoshiyuki

    2010-01-01

    Accurate evaluation of human epidermal growth factor receptor type-2 (HER2) status based on core needle biopsy (CNB) specimens is mandatory for identification of patients with primary breast cancer who will benefit from primary systemic therapy with trastuzumab. The aim of the present study was to validate the application of HER2 testing with CNB specimens from primary breast cancers in terms of interobserver reproducibility and comparison with surgically resected specimens. A total of 100 pairs of archival formalin-fixed paraffin-embedded CNB and surgically resected specimens of invasive breast carcinomas were cut into sections. All 100 paired sections were subjected to HER2 testing by immunohistochemistry (IHC) and 27 paired sections were subjected to that by fluorescence in situ hybridization (FISH), the results being evaluated by three and two observers, respectively. Interobserver agreement levels in terms of judgment and the concordance of consensus scores between CNB samples and the corresponding surgically resected specimens were estimated as the percentage agreement and κ statistic. In CNB specimens, the percentage interobserver agreement of HER2 scoring by IHC was 76% (κ = 0.71) for 3 × 3 categories (0-1+ versus 2+ versus 3+) and 90% (κ = 0.80) for 2 × 2 categories (0-2+ versus 3+). These levels were close to the corresponding ones for the surgically resected specimens: 80% (κ = 0.77) for 3 × 3 categories and 92% (κ = 0.88) for 2 × 2 categories. Concordance of consensus for HER2 scores determined by IHC between CNB and the corresponding surgical specimens was 87% (κ = 0.77) for 3 × 3 categories, and 94% (κ = 0.83) for 2 × 2 categories. Among the 13 tumors showing discordance in the mean IHC scores between the CNB and surgical specimens, the results of consensus for FISH results were concordant in 11. The rate of successful FISH analysis and the FISH positivity rate in cases with a HER2 IHC score of 2+ differed among specimens processed at

  1. HER2 testing on core needle biopsy specimens from primary breast cancers: interobserver reproducibility and concordance with surgically resected specimens

    Directory of Open Access Journals (Sweden)

    Yamamoto Sohei

    2010-10-01

    Full Text Available Abstract Background Accurate evaluation of human epidermal growth factor receptor type-2 (HER2 status based on core needle biopsy (CNB specimens is mandatory for identification of patients with primary breast cancer who will benefit from primary systemic therapy with trastuzumab. The aim of the present study was to validate the application of HER2 testing with CNB specimens from primary breast cancers in terms of interobserver reproducibility and comparison with surgically resected specimens. Methods A total of 100 pairs of archival formalin-fixed paraffin-embedded CNB and surgically resected specimens of invasive breast carcinomas were cut into sections. All 100 paired sections were subjected to HER2 testing by immunohistochemistry (IHC and 27 paired sections were subjected to that by fluorescence in situ hybridization (FISH, the results being evaluated by three and two observers, respectively. Interobserver agreement levels in terms of judgment and the concordance of consensus scores between CNB samples and the corresponding surgically resected specimens were estimated as the percentage agreement and κ statistic. Results In CNB specimens, the percentage interobserver agreement of HER2 scoring by IHC was 76% (κ = 0.71 for 3 × 3 categories (0-1+ versus 2+ versus 3+ and 90% (κ = 0.80 for 2 × 2 categories (0-2+ versus 3+. These levels were close to the corresponding ones for the surgically resected specimens: 80% (κ = 0.77 for 3 × 3 categories and 92% (κ = 0.88 for 2 × 2 categories. Concordance of consensus for HER2 scores determined by IHC between CNB and the corresponding surgical specimens was 87% (κ = 0.77 for 3 × 3 categories, and 94% (κ = 0.83 for 2 × 2 categories. Among the 13 tumors showing discordance in the mean IHC scores between the CNB and surgical specimens, the results of consensus for FISH results were concordant in 11. The rate of successful FISH analysis and the FISH positivity rate in cases with a HER2 IHC score of

  2. Computed-Tomography-Guided Percutaneous Core Needle Biopsies of Suspected Malignant Lymphomas: Impact of Biopsy, Lesion, and Patient Parameters on Diagnostic Yield

    International Nuclear Information System (INIS)

    Hesselmann, V.; Zaehringer, M.; Krug, B.; Wesselmann, C.; Haferkamp, K.; Wickenhauser, C.; Lackner, K.

    2004-01-01

    Purpose: To investigate the diagnostic yield of core needle biopsy in patients with malignant lymphoma. Material and Methods: Computed-tomography-guided core needle biopsies in patients with malignant lymphoma performed in the period 1996 to 2001 were evaluated retrospectively. A biopsy was considered as 'fully diagnostic' if a histological diagnosis, including the histologic subtype in the event of malignant lymphoma, was achieved and the clinical course and CT follow-up of at least 6 months confirmed the biopsy results. A biopsy was regarded as 'partly diagnostic' if histological work-up defined malignant lymphoma but not the histological subtype, and if histological diagnosis bore therapeutic relevance. Diagnostic yield was correlated with features such as size of specimen, location and depth of the target lesion, and experience of the investigator. Results: 45 biopsies were performed in 40 patients. With respect to definite histopathological diagnosis, 31 biopsies (68.9%) were diagnostic and 14 (31.1%) non-diagnostic. In 4 cases (8.8%), biopsies yielded partly diagnostic results, since therapy could be scheduled after biopsy without final sub-classification. Statistical analysis of biopsy parameters revealed that sample sizes were significantly larger in the diagnostic group. Conclusion: CT-guided biopsy can be considered as an alternative for lymphoma diagnosis and should be the first interventional procedure. The most important parameter for diagnostic success is the size of the specimen

  3. Usefulness of ultrasound-guided mammotome biopsy for microcalcification

    Energy Technology Data Exchange (ETDEWEB)

    Kim, You Me [Dankook University Hospital, Seoul (Korea, Republic of); Park, Hee Boong [Park Breast Clinic, Seoul (Korea, Republic of); Ryu, Jin Woo [Cheonan Choongmu Hospital, Cheonan (Korea, Republic of)

    2005-08-15

    To evaluate the usefulness of ultrasound-guided mammotome biopsy for microcalcification and to suggest a new approach for the localization of microcalcifications which are not detected on ultrasound. Twenty-one calcific lesions in 21 women (aged 33-56 years) underwent ultrasound-guided, vacuum-assisted, mammotome biopsy and a mean of 14 specimens per lesion were obtained. Calcification retrieval was defined as identification of calcifications on specimen radiographs. In the 13 cases of calcifications which were not detected on ultrasound imaging, mammotome biopsy was performed after localization of one or two needles at the microcalcifications under mammography-guidance. Radiographs of the specimens and histologic findings were reviewed and scheduled follow-up imaging was performed for evaluation of the complications of biopsy. Ultrasound-guided, vacuum-assisted, mammotome biopsy removed all calcifications in 21 lesions. Eight (38%) lesions showed visible calcification on the ultrasound while 13 (62%) lesions were invisible, which underwent mammotome biopsy after needle localization under mammography-guidance. Surgery revealed DCIS in 1 (4.8%) of 21 lesions, infiltrating ductal carcinoma in two (9.5%), fibroadenomas with calcifications in 6 (28.6%), fibroadenmas with adenosis in 2(9.5%), and fibrocystic change with calcifications in 10 (47.6%). Clinical significant complications did not occur on follow-up examination in any of the cases. Ultrasound-guided, vacuum-assisted, mammotome biopsy was an effective method for microcalcifications on mammogram. The results suggested that mammotome biopsy after mammogram-guided, needle localization is a good alternative method for the diagnosis of microcalcifications which are undetectable in the ultrasound images.

  4. Usefulness of ultrasound-guided mammotome biopsy for microcalcification

    International Nuclear Information System (INIS)

    Kim, You Me; Park, Hee Boong; Ryu, Jin Woo

    2005-01-01

    To evaluate the usefulness of ultrasound-guided mammotome biopsy for microcalcification and to suggest a new approach for the localization of microcalcifications which are not detected on ultrasound. Twenty-one calcific lesions in 21 women (aged 33-56 years) underwent ultrasound-guided, vacuum-assisted, mammotome biopsy and a mean of 14 specimens per lesion were obtained. Calcification retrieval was defined as identification of calcifications on specimen radiographs. In the 13 cases of calcifications which were not detected on ultrasound imaging, mammotome biopsy was performed after localization of one or two needles at the microcalcifications under mammography-guidance. Radiographs of the specimens and histologic findings were reviewed and scheduled follow-up imaging was performed for evaluation of the complications of biopsy. Ultrasound-guided, vacuum-assisted, mammotome biopsy removed all calcifications in 21 lesions. Eight (38%) lesions showed visible calcification on the ultrasound while 13 (62%) lesions were invisible, which underwent mammotome biopsy after needle localization under mammography-guidance. Surgery revealed DCIS in 1 (4.8%) of 21 lesions, infiltrating ductal carcinoma in two (9.5%), fibroadenomas with calcifications in 6 (28.6%), fibroadenmas with adenosis in 2(9.5%), and fibrocystic change with calcifications in 10 (47.6%). Clinical significant complications did not occur on follow-up examination in any of the cases. Ultrasound-guided, vacuum-assisted, mammotome biopsy was an effective method for microcalcifications on mammogram. The results suggested that mammotome biopsy after mammogram-guided, needle localization is a good alternative method for the diagnosis of microcalcifications which are undetectable in the ultrasound images

  5. Comparison of specimen adequacy in fine-needle aspiration biopsies performed by surgeons and pathologists

    International Nuclear Information System (INIS)

    Al-Marzooq, Yusef M.; Chopra, Rajan; Al-Bahrani, Ahmed T.; Younis, Mohammad; Al-Mulhim, Abdulrahman S.; Al-Mommatten, Mohammed I.

    2004-01-01

    Fine-needle aspiration biopsy (FNAB) may yield different results depending on its operator. We compared the proportions of unsatisfactory aspirates obtained by pathologists vs. surgeons. In a retrospective review, all FNAB reports and slides performed between March 2002 and February 2003 were grouped by organ/site and according to whether they were done by pathologist or a surgeon. The proportions of unsatisfactory aspirates for pathologists and surgeons were compared. Of 692 FNAB's, 390 were performed by pathologists at the FNAC clinic and the remainder by surgeons. Overall, 15.5% of aspirates obtained were unsatisfactory (n=107). Of aspirates obtained by surgeons, 29.5% were unsatisfactory, compared to 4.6% of those obtained by pathologists (P<0.001). Pathologists had significantly lower proportions of unsatisfactory aspirates in all sites. A 33% reduction in the number of lymph node excisional biopsies has been reported subsequent to establishment of the FNAC clinic. The advantages of a pathologist performing FNAB are that a rapid evaluation can be rendered regarding specimen adequacy and the need for repeating the procedure. In addition, pathologists can direct the distribution of aspirated material for other tests such as culture study, flow cytometry and electron microscopy, as indicated by preliminary evaluation of the smears. These factors significantly lower the proportions of unsatisfactory specimens and improve the diagnstic accuracy of FNAB technique. (author)

  6. A comparative kinetic RT/-PCR strategy for the quantitation of mRNAs in microdissected human renal biopsy specimens.

    Science.gov (United States)

    Del Prete, D; Forino, M; Gambaro, G; D'Angelo, A; Baggio, B; Anglani, F

    1998-01-01

    Molecular biology techniques, to be applicable to a diagnostic renal biopsy specimen, should (1) be highly sensitive to be performed on a very small quantity of tissue; (2) be quantitative because they have to analyze genes normally expressed in the tissue and (3) allow the analysis of as large a number of genes as possible. Among different methods, only the reverse-transcriptase polymerase chain reaction (RT/-PCR) might comply with previous requisites, but the few RT/-PCR examples on renal biopsies in the literature do not allow starting RNA quantification and quality control; furthermore they have the drawback of analyzing only few genes. In an ongoing study to assess the expression of a number of genes in glomeruli and in tubulointerstitium of patients with different nephropathies, we developed a comparative RT/-PCR kinetic strategy based on the purification and quantification of total glomerular and tubulointerstitial RNA and on the use of an internal standard, the housekeeping gene G3PDH. We demonstrate that in microdissected diagnostic renal biopsies (1) glomerular and interstitial starting RNA can be quantified; (2) the G3PDH gene may be used both as an internal standard and as an indirect marker of RNA integrity; (3) as low as 28 ng of total RNA is sufficient to obtain PCR products of eight genes, and (4) it is worth to operate on microdissected biopsy specimens because of the different expression of genes in the two renal compartments.

  7. Diagnostic multiplex polymerase chain reaction assay for the identification of Pseudomonas aeruginosa from the skin biopsy specimens in burn wound infections and detection of antibiotic susceptibility

    International Nuclear Information System (INIS)

    Mashouf, Rasoul Y.; Farahani, Hadi S.; Zamani, A.

    2008-01-01

    Objective was to identify Pseudomonas aeruginosa (P. aeruginosa) from the skin biopsy specimens in burn wound infections by multiplex polymerase chain reaction (M-PCR) and detection of antimicrobial susceptibility of isolates from culture. We conducted the cross-sectional study in 140 patients with wound infections who admitted to referral burn center of Motahari, Tehran, Iran, during a 12-month period from 2005-2006. Skin biopsy specimens were aseptically taken from each patient, one for PCR and one for bacterial culture. A M-PCR test based on simultaneous amplification of 2 lipoprotein genes: oprI and oprL, was used to directly detect fluorescent pseudomonades and P. aeruginosa in skin biopsy specimens. The susceptibility of P. aeruginosa isolates to 16 antibiotics was determined using the disc diffusion method. Out of 140 biopsy specimens, M-PCR detected 66 (47.2%) isolates, while culture detected 57 (40.7%) isolates as P. aeruginosa. Positive results for both genes which observed only for P. aeruginosa, while only one gene, oprI, was amplified from other fluorescent pseudomonades (n=12) and all other bacterial tested (n=62) were negative by the amplification test. The most effective antibiotics against isolate of P. aeruginosa were cefepime (79%), azetreonam (76%), ticarcillin-clavulanic acid (68%), tobramycin (62%) and amikacin (61%). Multiplex PCR assay appears promising for the rapid and sensitive detection of P. aeruginosa from the burned skin biopsy specimens. Simultaneous amplification of 2 lipoprotein genes: oprI and oprL could detect P. aeruginosa and oprI gene only for other fluorescent pseudomonades. (author)

  8. Liver Biopsies for Chronic Hepatitis C: Should Nonultrasound-Guided Biopsies Be Abandoned?

    Directory of Open Access Journals (Sweden)

    Jennifer A Flemming

    2009-01-01

    Full Text Available BACKGROUND/OBJECTIVE: Liver biopsy has been the gold standard for grading and staging chronic hepatitis C virus (HCV-mediated liver injury. Traditionally, this has been performed by trained practitioners using a nonimage-guided percutaneous technique at the bedside. Recent literature suggests an expanding role for radiologists in obtaining biopsies using an ultrasound (US-guided technique. The present study was undertaken study to determine if the two techniques produced liver biopsy specimens of similar quality and hypothesized that at our institution, non-US-guided percutaneous liver biopsies for HCV would be of higher quality than US-guided specimens.

  9. Significant histologic features differentiating cellular fibroadenoma from phyllodes tumor on core needle biopsy specimens.

    Science.gov (United States)

    Yasir, Saba; Gamez, Roberto; Jenkins, Sarah; Visscher, Daniel W; Nassar, Aziza

    2014-09-01

    Cellular fibroepithelial lesions (CFELs) are a heterogeneous group of tumors encompassing cellular fibroadenoma (CFA) and phyllodes tumor (PT). Distinction between the two is challenging on core needle biopsy (CNB) specimens. The objective of this study was to evaluate histologic features that can help distinguish PT from CFA on CNB specimens. Records of all patients diagnosed with CFELs on CNB specimens with follow-up excision between January 2002 and December 2012 were retrieved. Histopathologic stromal features were evaluated on CNB specimens, including mitoses per 10 high-power fields (hpf), overgrowth, increased cellularity, fragmentation, adipose tissue infiltration, heterogeneity, subepithelial condensation, and nuclear pleomorphism. Twenty-seven (42.2%) of 64 were diagnosed as PT (24 benign PTs and three borderline PTs) and 37 (57.8%) as CFA on excision. All features except for increased stromal cellularity were statistically significant. The average number of histologic features seen in PT and CFA was 3.9 and 1.4, respectively (odds ratio [OR], 7.27; 95% confidence interval [CI], 2.44-21.69; P = .0004). The average number of mitoses per 10 hpf was 3.0 for PT compared with 0.8 for CFA (OR, 2.14; 95% CI, 1.18-3.86; P = .01). The presence of mitoses (three or more) and/or total histologic features of three or more on CNB specimens were the most helpful features in predicting PT on excision. Copyright© by the American Society for Clinical Pathology.

  10. Transjugular liver biopsy : the efficacy of quick-core biopsy needle system

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Gyoo Sik; Ahn, Byung Kwon; Lee, Sang Ouk; Chang, Hee Kyong; Oh, Kyung Seung; Huh, Jin Do; Joh, Young Duk [Kosin Medical College, Pusan (Korea, Republic of)

    1998-02-01

    To evaluate the efficacy of the Quick-Core biopsy needle system in performing transjugular liver biopsy. Between December 1995 and June 1997, eight patients underwent transjugular liver biopsy involving use of the Quick-Core biopsy needle system; the conditions involved were coagulopathy (n=4), thrombocytopenia (n=3), and ascites (n=1). Via the right internal jugular vein, the right hepatic vein was selectively catheterized with a 7-F transjugular guiding catheter, and a14-guage stiffening cannula was then inserted through this catheter; to obtain core tissue, a Quick-Core needle was then advanced into the liver parenchyma through the catheter-cannula combination. Eighteen- and 19-guage needles were used in three and five patients, respectively; specimen size, adequacy of the biopsy specimen and histologic diagnosis were determined, and complications were recorded. Biopsy was successful in all patients. The mean length of the specimen was 1.4 cm (1.0 - 1.8 cm), and all were adequate for pathologic examinations ; specific diagnosis was determined in all patients. There were two malignant neoplasms, two cases of veno-occlusive disease, and one case each of cirrhosis, fulminant hepatitis, Banti syndrome and Budd-Chiari syndrome. One patient complained of neck pain after the procedure, but no serious procedural complications were noted. Our preliminary study shows that the Quick-Core biopsy needle system is safe and provides adequate core tissues with high diagnostic yields. (author). 23 refs., 1 tab., 3 figs.

  11. Transjugular liver biopsy : the efficacy of quick-core biopsy needle system

    International Nuclear Information System (INIS)

    Jung, Gyoo Sik; Ahn, Byung Kwon; Lee, Sang Ouk; Chang, Hee Kyong; Oh, Kyung Seung; Huh, Jin Do; Joh, Young Duk

    1998-01-01

    To evaluate the efficacy of the Quick-Core biopsy needle system in performing transjugular liver biopsy. Between December 1995 and June 1997, eight patients underwent transjugular liver biopsy involving use of the Quick-Core biopsy needle system; the conditions involved were coagulopathy (n=4), thrombocytopenia (n=3), and ascites (n=1). Via the right internal jugular vein, the right hepatic vein was selectively catheterized with a 7-F transjugular guiding catheter, and a14-guage stiffening cannula was then inserted through this catheter; to obtain core tissue, a Quick-Core needle was then advanced into the liver parenchyma through the catheter-cannula combination. Eighteen- and 19-guage needles were used in three and five patients, respectively; specimen size, adequacy of the biopsy specimen and histologic diagnosis were determined, and complications were recorded. Biopsy was successful in all patients. The mean length of the specimen was 1.4 cm (1.0 - 1.8 cm), and all were adequate for pathologic examinations ; specific diagnosis was determined in all patients. There were two malignant neoplasms, two cases of veno-occlusive disease, and one case each of cirrhosis, fulminant hepatitis, Banti syndrome and Budd-Chiari syndrome. One patient complained of neck pain after the procedure, but no serious procedural complications were noted. Our preliminary study shows that the Quick-Core biopsy needle system is safe and provides adequate core tissues with high diagnostic yields. (author). 23 refs., 1 tab., 3 figs

  12. Significant association between renal function and amyloid-positive area in renal biopsy specimens in AL amyloidosis

    Directory of Open Access Journals (Sweden)

    Kuroda Takeshi

    2012-09-01

    Full Text Available Abstract Background The kidney is a major target organ for systemic amyloidosis that often affects the kidney including proteinura, and elevated serum creatinine (Cr. The correlation between amount of amyloid deposits and clinical parameters is not known. The aim of this study was to clarify correlation the amyloid area in all renal biopsy specimen and clinical parameters. Methods Fifty-eight patients with an established diagnosis of AL amyloidosis participated in the study. All patients showed amyloid deposits in renal biopsies. We retrospectively investigated the correlation between clinical data and amyloid occupied area in whole renal biopsy specimens. Results The area occupied by amyloid was less than 10% in 57 of the 58 patients, and was under 2% in 40. For statistical analyses, %amyloid-positive areas were transformed to common logarithmic values (Log10%amyloid. Cr showed significant correlation with Log10%amyloid and estimated glomerular filtration rate (eGFR showed the significant negative correlation. Patient age, cleatinine clearance (Ccr, blood urea nitorogen, and urinary protein was not significantly correlated with Log10%amyloid. The correlation with other clinical factors such as sex, and serum concentrations of total protein, albumin, immunoglobulins, compliments was evaluated. None of these factors significantly correlated with Log10%amyloid. According to sex- and age- adjusted multiple linear regression analysis, Log10%amyloid had significant positive association with Cr and significant negative association with eGFR. Conclusion There is significant association between amyloid-positive area in renal tissue and renal function, especially Cr and eGFR. The level of Cr and eGFR may be a marker of amount of amyloid in renal tissue.

  13. Rotary powered device for bone marrow aspiration and biopsy yields excellent specimens quickly and efficiently.

    Science.gov (United States)

    Swords, Ronan T; Kelly, Kevin R; Cohen, Stephen C; Miller, Larry J; Philbeck, Thomas E; Hacker, Sander O; Spadaccini, Cathy J; Giles, Francis J; Brenner, Andrew J

    2010-06-01

    Recently, a new FDA-cleared battery powered bone marrow biopsy system was developed to allow operators access to the bone marrow space quickly and efficiently. A pre-clinical evaluation of the device (OnControl, Vidacare Corporation, San Antonio, TX, USA) on anesthetized pigs was conducted, in addition to a clinical evaluation in hematology clinic patients requiring a bone marrow biopsy. Twenty-six samples were collected from the swine model. No cellular artifact or thermal damage was reported in any of the samples obtained. For the clinical evaluation of the device, 16 patients were recruited. Mean time from needle contact with skin to needle removal was 38.5 +/- 13.94 seconds. No complications were reported. In this study, the manual and powered samples were equivalent in specimen quality. In the patients evaluated, the device was safe, easy to use and the mean procedural time was significantly faster than previously reported with a manual technique.

  14. Functional quality of MR-compatible automatic biopsy guns compared with conventional ferromagnetic biopsy systems. An in vitro study

    International Nuclear Information System (INIS)

    Langen, H.J.; Landwehr, P.

    2001-01-01

    Comparative evaluation of specimens obtained with different MR-compatible biopsy systems and a conventional ferromagnetic system. Methods: Biopsies of a pig liver were performed post-mortem with three different MR-compatible (Somatex; E-Z-EM; Daum) and one conventional biopsy system (Somatex), five with each device. The specimens were measured and the histopathological quality was graded on a scale from 0 (no tissue) to 9 (best). The tip of the needle was examined with an electron microscope before and after biopsy to demonstrate abrasion. Results: The histopathological score between the first and fifth specimen taken with one biopsy device showed no significant difference. The conventional system yielded significantly better results in nearly all categories (p 2 ) were significantly smaller than those from the conventional system (9.98 mm 2 ). The needle tip abrasion of the different biopsy systems determined by electron microscopy showed no substantial difference. (orig.) [de

  15. Primary Signet Ring Cell Carcinoma of Rectum Diagnosed by Boring Biopsy in Combination with Endoscopic Mucosal Resection

    Directory of Open Access Journals (Sweden)

    Yoshito Hirata

    2018-01-01

    Full Text Available A 46-year-old man with severe back pain visited our hospital. Magnetic resonance imaging revealed extensive bone metastasis and rectal wall thickness. Colonoscopy revealed circumferential stenosis with edematous mucosa, suggesting colon cancer. However, histological findings of biopsy specimens revealed inflammatory cells but no malignant cells. The patient underwent endoscopic ultrasound, which demonstrated edematous wall thickness without destruction of the normal layer structure. After unsuccessful detection of neoplastic cells by boring biopsies, we performed endoscopic mucosal resection followed by boring biopsies that finally revealed signet ring cell carcinoma. Herein, we present a case and provide a review of the literature.

  16. Improved transvenous liver biopsy needle

    DEFF Research Database (Denmark)

    Henriksen, Jens Henrik Sahl; Matzen, P; Christoffersen, P

    1979-01-01

    A modified type of the standard transvenous cholangiography biopsy needle is described. The modified tranvenous liver biopsy needle caused only minimal artefactual changes of the liver biopsy specimens. The new type of biopsy needle is a modified Menghini needle. The conventional Menghini needle...... should be avoided for transvenous catheter biopsies because of risk of leaving catheter fragments in the liver....

  17. The value of touch imprint cytology of prostate core needle biopsy ...

    African Journals Online (AJOL)

    The value of touch imprint cytology of prostate core needle biopsy specimens ... prostate cancer as indicated by a high prostate serum antigen (PSA) level or ... revealed benign features in 7 and prostatitis in 17, while high-grade prostatic ...

  18. Eosinophils are rare in biopsy specimens of psoriasis vulgaris.

    Science.gov (United States)

    Rosa, Gabriela; Fernandez, Anthony P; Schneider, Sarah; Billings, Steven D

    2017-12-01

    Histological features of lesional biopsies can be helpful in distinguishing psoriasis subtypes from disease mimickers. However, occasionally, classic histological features are not sufficient for distinction, and additional clues would be useful. There is a common belief that the presence of eosinophils in skin biopsies argues against psoriasis, but actual literature is scant. Skin biopsies with a diagnosis of psoriasis from 2013 to 2016 were reviewed. For inclusion, both histological and clinical features were required to be consistent with psoriasis. For biopsies meeting inclusion criteria, a detailed evaluation for typical histological parameters of psoriasis, as well as presence of dermal eosinophils, was performed. Of 85 cases meeting inclusion criteria, all had either individual or grouped intracorneal neutrophils and dilated papillary blood vessels. Diminished or complete loss of the granular cell layer was seen in 83 cases (98%), and parakeratosis was seen in 84 cases (99%). Alternatively, dermal eosinophils were seen in only 15 cases (18%). Of cases with eosinophils, none had more than 3 eosinophils upon examination of the entire dermis. Active treatment did not appear to impact presence/absence or numbers of eosinophils. Eosinophils are uncommon in psoriasis biopsies, and when present, they are found in small numbers. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  19. Ultrasound-guided renal biopsy: experience using an automated core biopsy system.

    Science.gov (United States)

    Chan, R; Common, A A; Marcuzzi, D

    2000-04-01

    To assess the safety and efficacy of ultrasound-guided percutaneous renal biopsy using an automated core biopsy system, and to determine radiologists' accuracy in predicting sample adequacy. Ninety-five biopsies were performed on 25 native kidneys and 70 renal allografts using a 16-gauge automated, spring-loaded core biopsy device under real-time sonographic guidance. Radiologists performing the biopsy estimated the number of core samples needed to obtain an adequate specimen, based on visual inspection of each core. The final determination of the number of samples was made by a pathology technologist who attended each biopsy, based on preliminary microscopic examination of tissue cores. After each biopsy, an ultrasonographic examination was performed to search for biopsy-related hemorrhage, and a questionnaire was given to the patient to determine biopsy-related complications, which were categorized as either minor or major. The main indication for biopsy was acute renal failure (in 43.2% of biopsies). An average of 3 tissue cores per biopsy were obtained. Of the 94 patients in whom a biopsy was conducted to exclude diffuse renal disease, a mean of 12.5 glomeruli were present in each specimen. Overall, adequate tissue for diagnosis was obtained in 98.9% of cases. The radiologists' estimate of the number of core samples needed concurred with the pathology technologists' determination of sample adequacy in 88.4% of cases. A total of 26 complications occurred (in 27.4% of biopsies), consisting of 23 minor (24.2%) and 3 major (3.2%) complications. Real-time sonographic guidance in conjunction with an automated core biopsy system is a safe and accurate method of performing percutaneous renal biopsy. Routine use of sonographic examinations to search for biopsy-related complications is not indicated. Radiologists are accurate in estimating sample adequacy in most cases; however, the presence of a pathology technologist at the biopsy procedure virtually eliminates the

  20. Discrepancies between biopsy-based and excision-based grading of cervical intraepithelial neoplasia: the important role of time between excision and biopsy.

    Science.gov (United States)

    Zhang, Lu; Li, Qiang; Zhao, Mingyu; Jia, Lin; Zhang, Youzhong

    2015-05-01

    We sought to evaluate the rate of cervical intraepithelial neoplasia (CIN) ≤ 1 in loop electrosurgical excision procedure (LEEP) specimens after the treatment of biopsy-proven CIN 2-3, and to identify factors that are associated with the rate of CIN ≤ 1, especially focusing on the time interval between biopsy and LEEP. The goal of this research is to reduce the overtreatment of women with CIN 2-3. This was a retrospective study performed on women undergoing LEEP for biopsy-proven CIN 2-3 in Qilu hospital in Shandong, China. Patients were separated according to LEEP pathology (CIN ≤ 1 vs. CIN 2-3), and compared using the χ2 test and Student t test. The main outcome measures were pathologic discrepancy (defined as CIN 2-3 at biopsy, but CIN ≤ 1 at excision). Of the 391 women with biopsy-proven CIN 2-3, 26.9% had LEEP specimens with CIN ≤ 1 histologies. The likelihood of a CIN ≤ 1 LEEP specimen increases for greater biopsy-LEEP intervals (odds ratio, 1.374; 95% confidence interval, 1.089-1.735; P = 0.008). Cases in younger women and biopsy-assessed CIN 2 cases were both more likely to have CIN 1 or negative LEEP specimens. The rate of spontaneous histologic regression (defined as CIN ≤ 1 at resection) was 26.9%. These low-grade lesions were more common in LEEP specimens from young women with CIN 2 at biopsy, and who underwent LEEP later after the initial biopsy.

  1. Evaluation of an endoscopic liver biopsy technique in green iguanas.

    Science.gov (United States)

    Hernandez-Divers, Stephen J; Stahl, Scott J; McBride, Michael; Stedman, Nancy L

    2007-06-15

    To establish a safe and effective endoscopic technique for collection of liver biopsy specimens from lizards by use of a 2.7-mm rigid endoscope system that is commonly available in zoologic veterinary practice. Prospective study. 11 subadult male green iguanas (Iguana iguana). Each lizard was anesthetized, and right-sided coelioscopic examination of the right liver lobe and gallbladder was performed. Three liver biopsy specimens were collected from each lizard by use of a 2.7-mm rigid endoscope and 1.7-mm (5-F) biopsy forceps. Biopsy samples were evaluated histologically for quality and crush artifact. Ten days following surgery, all iguanas were euthanatized and underwent full necropsy examination. For all 11 iguanas, the right liver lobe and gallbladder were successfully examined endoscopically, and 3 biopsy specimens of the liver were collected without complications. Mean +/- SD durations of anesthesia and surgery were 24 +/- 7 minutes and 6.8 +/- 1.0 minutes, respectively. At necropsy, there was no evidence of trauma or disease associated with the skin or muscle entry sites, liver, or any visceral structures in any iguana. All 33 biopsy specimens were considered acceptable for histologic interpretation; in most samples, the extent of crush artifact was considered minimal. By use of a 2.7-mm rigid endoscope, liver biopsy procedures can be performed safely, swiftly, and easily in green iguanas. Biopsy specimens obtained by this technique are suitable for histologic examination. For evaluation of the liver and biopsy specimen collection in lizards, endoscopy is recommended.

  2. The Diagnosis of Gastric Mucosa-associated Lymphoid Tissue Lymphoma by Flow Cytometry and Fluorescence in situ Hybridization of Biopsy Specimens.

    Science.gov (United States)

    Matsueda, Katsunori; Omote, Sizuma; Sakata, Masahiro; Fujita, Isao; Horii, Jouichiro; Toyokawa, Tatsuya

    2018-04-15

    Mucosa-associated lymphoid tissue (MALT) lymphoma and reactive inflammatory lymphoid changes are frequently difficult to distinguish based on a routine histological differential diagnosis. We were unable to diagnose gastric MALT lymphoma histologically using specimens obtained by endoscopy, although a flow cytometry (FCM) analysis demonstrated clonality of neoplastic cells by separating cells by CD45 gating. Furthermore, a fluorescence in situ hybridization (FISH) analysis showed trisomy 18. We therefore diagnosed gastric MALT lymphoma with trisomy 18. We recommend that FCM and FISH analyses of biopsy specimens be considered for diagnosing gastric MALT lymphoma if this diagnosis is suspected based on endoscopic findings.

  3. Ultrasound-guided forceps for pleural biopsy

    Directory of Open Access Journals (Sweden)

    Gamal Agmy

    2014-04-01

    Clinical implications: Ultrasound-guided forceps for pleural biopsy can overcome many of the limitations of the conventional needle biopsy procedures, provides multiple biopsy specimens of the parietal pleura that are inaccessible to the biopsy needle, and can be carried out easily and safely even in sick and obese patients. The diagnostic yield is nearly similar to thoracoscopy.

  4. Towards real-time metabolic profiling of a biopsy specimen during a surgical operation by 1H high resolution magic angle spinning nuclear magnetic resonance: a case report

    Directory of Open Access Journals (Sweden)

    Piotto Martial

    2012-01-01

    Full Text Available Abstract Introduction Providing information on cancerous tissue samples during a surgical operation can help surgeons delineate the limits of a tumoral invasion more reliably. Here, we describe the use of metabolic profiling of a colon biopsy specimen by high resolution magic angle spinning nuclear magnetic resonance spectroscopy to evaluate tumoral invasion during a simulated surgical operation. Case presentation Biopsy specimens (n = 9 originating from the excised right colon of a 66-year-old Caucasian women with an adenocarcinoma were automatically analyzed using a previously built statistical model. Conclusions Metabolic profiling results were in full agreement with those of a histopathological analysis. The time-response of the technique is sufficiently fast for it to be used effectively during a real operation (17 min/sample. Metabolic profiling has the potential to become a method to rapidly characterize cancerous biopsies in the operation theater.

  5. A trucut biopsy needle for bipolar radiofrequency ablation of needle tract: a proof-of-concept experiment.

    Science.gov (United States)

    Bruners, Philipp; Penzkofer, Tobias; Isfort, Peter; Pfeffer, Jochen; Schmitz-Rode, Thomas; Günther, Rolf W; Mahnken, Andreas H

    2010-08-01

    To develop a trucut biopsy needle featuring two electrodes that allow for bipolar radiofrequency (RF) coagulation of the puncture tract. We modified a 14-G trucut biopsy needle to contain two insulated electrodes and connected the device to an RF generator. Biopsies in ex vivo porcine liver and kidney were performed. The puncture tract was coagulated by using different RF energy settings (5 W, 10 W, 20 W). Tissue specimens were dissected along the puncture tract and the coagulation area was macroscopically evaluated. CT-guided in vivo liver and kidney biopsies were performed in two domestic pigs. Lengths of specimens were measured. Post-biopsy contrast-enhanced CT examinations were performed to rule out biopsy-related bleeding. Animals were euthanised and coagulation areas macroscopically explored. The mean diameters of the coagulated area around the ex vivo biopsy tract were 4.2 +/- 1.1 mm (5 W), 6.0 +/- 2.0 mm (10 W) and 5.2 +/- 0.51 mm (20 W) in liver and 5.0 +/- 0.7 mm (5 W), 6.6 +/- 0.9 (10 W) and 6.0 +/- 2.0 mm (20 W) in kidney. After biopsies CT revealed no bleeding. Mean maximum coagulation diameters were 10.1 +/- 4.6 mm (10 W) in liver and 6.0 +/- 2.5 mm (10 W) in kidney. Mean length of the specimens was 12.2 +/- 4.4 mm in kidney and 11.1 +/- 3.6 mm in liver tissue. Bipolar RF biopsy is a promising tool for tract coagulation after percutaneous biopsy.

  6. A trucut biopsy needle for bipolar radiofrequency ablation of needle tract: a proof-of-concept experiment

    International Nuclear Information System (INIS)

    Bruners, Philipp; Penzkofer, Tobias; Isfort, Peter; Pfeffer, Jochen; Schmitz-Rode, Thomas; Guenther, Rolf W.; Mahnken, Andreas H.

    2010-01-01

    To develop a trucut biopsy needle featuring two electrodes that allow for bipolar radiofrequency (RF) coagulation of the puncture tract. We modified a 14-G trucut biopsy needle to contain two insulated electrodes and connected the device to an RF generator. Biopsies in ex vivo porcine liver and kidney were performed. The puncture tract was coagulated by using different RF energy settings (5 W, 10 W, 20 W). Tissue specimens were dissected along the puncture tract and the coagulation area was macroscopically evaluated. CT-guided in vivo liver and kidney biopsies were performed in two domestic pigs. Lengths of specimens were measured. Post-biopsy contrast-enhanced CT examinations were performed to rule out biopsy-related bleeding. Animals were euthanised and coagulation areas macroscopically explored. The mean diameters of the coagulated area around the ex vivo biopsy tract were 4.2 ± 1.1 mm (5 W), 6.0 ± 2.0 mm (10 W) and 5.2 ± 0.51 mm (20 W) in liver and 5.0 ± 0.7 mm (5 W), 6.6 ± 0.9 (10 W) and 6.0 ± 2.0 mm (20 W) in kidney. After biopsies CT revealed no bleeding. Mean maximum coagulation diameters were 10.1 ± 4.6 mm (10 W) in liver and 6.0 ± 2.5 mm (10 W) in kidney. Mean length of the specimens was 12.2 ± 4.4 mm in kidney and 11.1 ± 3.6 mm in liver tissue. Bipolar RF biopsy is a promising tool for tract coagulation after percutaneous biopsy. (orig.)

  7. The Effectiveness of Mapping Biopsy in Patients with Extramammary Paget's Disease

    Directory of Open Access Journals (Sweden)

    Byung Jun Kim

    2014-11-01

    Full Text Available BackgroundExtramammary Paget's disease (EMPD is an intraepithelial carcinoma usually occurring on the skin or mucosa of the perineum. Clinically, it resembles eczema or dermatitis, and misdiagnosis and treatment delays are common. The treatment of choice for EMPD is a wide excision with adequate margins. Wide excision with intraoperative frozen biopsy and Mohs micrographic surgery are common methods; however, these are associated with a high recurrence rate and long operation time, respectively.MethodsBetween January 2010 and June 2013, 21 patients diagnosed with EMPD underwent mapping biopsy. Biopsy specimens were collected from at least 10 areas, 2 cm from the tumor margin. When the specimens were positive for malignancy, additional mapping biopsy was performed around the biopsy site of the positive result, and continued until no cancer cells were found. Based on the results, excision margins and reconstruction plans were established preoperatively.ResultsThe patients (18 male, 3 female had a mean age of 66.5 years (range, 50-82 years. Almost all cases involved in the perineal area, except one case of axillary involvement. Permanent biopsy revealed one case (4.8% of positive cancer cells on the resection margin, in which additional mapping biopsy and re-operation was performed. At the latest follow-up (mean, 27.4 months; range, 12-53 months, recurrence had not occurred.ConclusionsPreoperative mapping biopsy enables accurate resection margins and a preoperative reconstructing plan. Additionally, it reduces the operation time and risk of recurrence. Accordingly, it represents an effective alternative to Mohs micrographic surgery and wide excision with intraoperative frozen biopsy.

  8. Accuracy of percutaneous lung biopsy for invasive pulmonary aspergillosis

    Energy Technology Data Exchange (ETDEWEB)

    Hoffer, F.A. [Dept. of Diagnostic Imaging, St. Jude Children' s Research Hospital, Memphis, TN (United States); Gow, K.; Davidoff, A. [Dept. of Surgery, St. Jude Children' s Research Hospital, Memphis, TN (United States); Flynn, P.M. [Dept. of Infectious Diseases, St. Jude Children' s Research Hospital, Memphis, TN (United States)

    2001-03-01

    Background. Invasive pulmonary aspergillosis is fulminant and often fatal in immunosuppressed patients. Percutaneous biopsy may select patients who could benefit from surgical resection. Objective. We sought to determine the accuracy of percutaneous biopsy for pediatric invasive pulmonary aspergillosis. Materials and methods. We retrospectively reviewed 28 imaging-guided percutaneous biopsies of the lungs of 24 children with suspected pulmonary aspergillosis. Twenty-two were being treated for malignancy and two for congenital immunodeficiency; 15 had received bone-marrow transplants. The accuracy of the percutaneous lung biopsy was determined by subsequent surgical resection, autopsy, or clinical course. Results. Histopathological studies showed ten biopsy specimens with septate hyphae, indicating a mold, and seven with Aspergillus flavus colonies in culture. The remaining 18 biopsies revealed no fungi. No patient had progressive aspergillosis after negative biopsy. Invasive pulmonary mold was detected by percutaneous biopsy with 100 % (10/10) sensitivity and 100 % (18/18) specificity. Percutaneous biopsy results influenced the surgical decision in 86 % (24 of 28) of the cases. Bleeding complicated the biopsy in 46 % (13/28) and hastened one death. Conclusion. Percutaneous biopsy of the lung is an accurate technique for the diagnosis of invasive pulmonary aspergillosis and correctly determines which immunosuppressed pediatric patients would benefit from therapeutic pulmonary resection. (orig.)

  9. Accuracy of percutaneous lung biopsy for invasive pulmonary aspergillosis

    International Nuclear Information System (INIS)

    Hoffer, F.A.; Gow, K.; Davidoff, A.; Flynn, P.M.

    2001-01-01

    Background. Invasive pulmonary aspergillosis is fulminant and often fatal in immunosuppressed patients. Percutaneous biopsy may select patients who could benefit from surgical resection. Objective. We sought to determine the accuracy of percutaneous biopsy for pediatric invasive pulmonary aspergillosis. Materials and methods. We retrospectively reviewed 28 imaging-guided percutaneous biopsies of the lungs of 24 children with suspected pulmonary aspergillosis. Twenty-two were being treated for malignancy and two for congenital immunodeficiency; 15 had received bone-marrow transplants. The accuracy of the percutaneous lung biopsy was determined by subsequent surgical resection, autopsy, or clinical course. Results. Histopathological studies showed ten biopsy specimens with septate hyphae, indicating a mold, and seven with Aspergillus flavus colonies in culture. The remaining 18 biopsies revealed no fungi. No patient had progressive aspergillosis after negative biopsy. Invasive pulmonary mold was detected by percutaneous biopsy with 100 % (10/10) sensitivity and 100 % (18/18) specificity. Percutaneous biopsy results influenced the surgical decision in 86 % (24 of 28) of the cases. Bleeding complicated the biopsy in 46 % (13/28) and hastened one death. Conclusion. Percutaneous biopsy of the lung is an accurate technique for the diagnosis of invasive pulmonary aspergillosis and correctly determines which immunosuppressed pediatric patients would benefit from therapeutic pulmonary resection. (orig.)

  10. Significance of endoscopic biopsy after preoperative irradiation therapy for rectal cancer

    Energy Technology Data Exchange (ETDEWEB)

    Takiguchi, Nobuhiro; Sarashina, Hiromi; Saito, Norio; Nunomura, Masao; Kohda, Keishi; Nakajima, Nobuyuki (Chiba Univ. (Japan). School of Medicine)

    1994-05-01

    To evaluate the utility of endoscopic biopsy before and after preoperative irradiation therapy for rectal cancer, we examined histologically both biopsy specimens and resected materials of forty-three patients. Two pieces of biopsy materials were taken both before and after irradiation therapy (total dose 42.6 Gy) from the marginal wall of the tumor, cavity and transitional mucosa, respectively. In biopsy specimens, according to the degree of degeneration of cancer cells, cases with remarkable changes of nucleus, nucleolus, and cytoplasm due to irradiation were classified into the severely degenerated group. According to the histological examinations of resected materials, twenty-four cases were under Grade 1b (Gr I), and nineteen cases were over Grade 2 (Gr II). The rates of cancer cells found in biopsy materials after irradiation were 91.7% in Gr I and were 47.4% in Gr II, respectively (p<0.01). Among the cases, 54.5% in Gr I and 100% in Gr II belonged to the severely degenerated group (p<0.05). Transitional mucosas were not greatly damaged by irradiation. As a result, the greater the irradiation effect was, the fewer cancer cells were found and the more degenerated cancer cells were found in biopsy specimens. But the rate of severely degenerated cells found in the biopsy specimens of little effect cases was high. So it was thought to be too difficult to predict the histological radiation effect of resected specimens from only biopsy specimens. (author).

  11. A randomized controlled trial of electrocoagulation-enabled biopsy versus conventional biopsy in the diagnosis of endobronchial lesions.

    Science.gov (United States)

    Khan, Ajmal; Aggarwal, Ashutosh N; Agarwal, Ritesh; Bal, Amanjit; Gupta, Dheeraj

    2011-01-01

    Although electrocoagulation at time of endobronchial biopsy can potentially reduce procedure-related bleeding during fiberoptic bronchoscopy (FOB), it can also impair quality of tissue specimen; credible data for either are lacking. To evaluate the impact of hot biopsy on the quality of tissue samples and to quantify the amount of procedure-related bleeding during endobronchial biopsy. In this single-center, prospective, single-blind, randomized controlled study we included adult patients referred for FOB and having endobronchial lesions. Patients were randomized to bronchial biopsy using an electrocoagulation-enabled biopsy forceps, with (EC+ group) or without (EC- group) application of electrocoagulation current (40 W for 10 s in a monopolar mode). Procedure-related bleeding was semi-quantified by observer description, as well as through a visual analogue scale. Overall quality of biopsy specimen and tissue damage were assessed and graded by a pulmonary pathologist blinded to FOB details. 160 patients were randomized to endobronchial biopsy with (n = 81) or without (n = 79) the application of electrocoagulation. There were no severe bleeding episodes in either group, and severity of bleeding in the EC+ and EC- groups was similar (median visual analogue scale scores of 14 and 16, respectively). Histopathological diagnosis was similar in the EC+ and EC- groups (77.8% and 82.3%, respectively). There was no significant difference in tissue quality between the two groups. Use of electrocoagulation-enabled endobronchial biopsy does not alter specimen quality and does not result in any significant reduction in procedure-related bleeding. Copyright © 2010 S. Karger AG, Basel.

  12. Clinical significance of inadequate endometrial biopsies prior to hysterectomy.

    Science.gov (United States)

    Turney, Emily H; Farghaly, Hanan; Eskew, Ashley M; Parker, Lynn P; Milam, Michael R

    2012-01-01

    To evaluate preoperative clinical risk factors associated with significant uterine histopathologic abnormalities in final hysterectomy specimens in patients with inadequate preoperative endometrial biopsies. This is an institutional review board-approved, retrospective cohort analysis of 469 consecutive patients who underwent preoperative endometrial biopsies with subsequent hysterectomy from January 1, 2005, to December 31, 2009, at the University of Louisville Medical Center. We analyzed risk factors for inadequate biopsy and for final diagnosis of endometrial pathology (defined as endometrial hyperplasia or uterine cancer). Of the 469 preoperative endometrial biopsies reviewed, 26.2% (123/469) were inadequate (IBx) and 73.8% (346/469) were adequate and benign. IBx on endometrial biopsies was associated with a greater risk of having significant uterine histopathologic abnormalities on final hysterectomy specimens (6.5% vs. 2.3%, RR 2.8 [95% CI 1.1-7.3], p = 0.04). Although inadequate endometrial biopsies are a common finding, they can be associated with significant uterine histopathologic abnormalities on final hysterectomy specimens.

  13. Radiologically Guided Bone Biopsy: Results of 502 Biopsies

    International Nuclear Information System (INIS)

    Ng, Chaan S.; Salisbury, Jonathan R.; Darby, Alan J.; Gishen, Philip

    1998-01-01

    Purpose: To analyze the results of 502 biopsies over a 19-year period for the purpose of highlighting the results that can be expected from such a large study, with emphasis on needle choice and anesthetic methods. Methods: The histological, cytological, and microbiological results of 477 patients who had 502 bone biopsies carried out between July 1977 and March 1996 were studied. Less than 5% of patients required second biopsies. There were almost equal numbers of males and females in the group. The lesions were visible radiologically and most of the biopsies were carried out by a single operator. The lesions were classified on their histopathological, cytopathological, and microbiological findings. Results: Tumors accounted for 40% of the biopsies, and infection for 16%. Biopsies which did not yield a 'positive' diagnosis accounted for 31%; these included specimens reported as normal, or as showing reactive changes, repair, remodelling, non-specific features, inflammation (but not clearly infective), or no evidence of malignancy or inflammation. Less than 4% of biopsies were incorrect, and some of these were re-biopsied. Conclusion: Bone biopsy is a valuable technique for positive diagnosis of malignancy or infection, as it enables a definitive plan for treatment and management of patients to be established. Exclusion of serious pathology is almost equally important. In principle, any osseous site can be biopsied using fluoroscopic or computed tomographic guidance. Care in the biopsy technique and selection of the bone needle is required

  14. Digital quantification of gene expression in sequential breast cancer biopsies reveals activation of an immune response.

    Directory of Open Access Journals (Sweden)

    Rinath M Jeselsohn

    Full Text Available Advancements in molecular biology have unveiled multiple breast cancer promoting pathways and potential therapeutic targets. Large randomized clinical trials remain the ultimate means of validating therapeutic efficacy, but they require large cohorts of patients and are lengthy and costly. A useful approach is to conduct a window of opportunity study in which patients are exposed to a drug pre-surgically during the interval between the core needle biopsy and the definitive surgery. These are non-therapeutic studies and the end point is not clinical or pathological response but rather evaluation of molecular changes in the tumor specimens that can predict response. However, since the end points of the non-therapeutic studies are biologic, it is critical to first define the biologic changes that occur in the absence of treatment. In this study, we compared the molecular profiles of breast cancer tumors at the time of the diagnostic biopsy versus the definitive surgery in the absence of any intervention using the Nanostring nCounter platform. We found that while the majority of the transcripts did not vary between the two biopsies, there was evidence of activation of immune related genes in response to the first biopsy and further investigations of the immune changes after a biopsy in early breast cancer seem warranted.

  15. Pathological discrepancy between colposcopic directed cervical biopsy and Loop Electrosurgical-Excision Procedures (LEEPs in patients with biopsies proven high grade cervical intraepithelial neoplasia

    Directory of Open Access Journals (Sweden)

    Sitchuphong Noothong

    2017-10-01

    Conclusion: The prevalence of patients with CIN1 or less from LEEP specimens who previously had colposcopic biopsies proven CIN2 or 3 was 16.3%. CIN2 from biopsy was the statistically significant risk factor of CIN1 or less in LEEP specimens.

  16. The accuracy of colposcopic biopsy

    DEFF Research Database (Denmark)

    Stoler, Mark H; Vichnin, Michelle D; Ferenczy, Alex

    2011-01-01

    We evaluated the overall agreement between colposcopically directed biopsies and the definitive excisional specimens within the context of three clinical trials. A total of 737 women aged 16-45 who had a cervical biopsy taken within 6 months before their definitive therapy were included. Per-prot...

  17. Prostate biopsy after definitive treatment by interstitial iodine 125 implant or external beam radiation therapy

    International Nuclear Information System (INIS)

    Schellhammer, P.F.; el-Mahdi, A.M.; Higgins, E.M.; Schultheiss, T.E.; Ladaga, L.E.; Babb, T.J.

    1987-01-01

    The response to definitive radiation therapy of localized carcinoma of the prostate by iodine 125 implantation or external beam radiotherapy was monitored by examining specimens from biopsies performed after treatment. We analyzed 126 biopsy specimens obtained 18 months or more after treatment: 71 were obtained from 109 patients treated by iodine 125 and 55 from 197 patients treated by external beam radiotherapy. Thereafter, the disease status of these patients was examined at minimum 3-year intervals. No significant statistical difference was found between the negative specimen rates of the 2 treatment modalities: 46 of 71 (65 per cent) after iodine 125 implantation and 39 of 55 (71 per cent) after external beam radiotherapy were negative. To analyze the predictive value of biopsy results 103 patients whose prostatic examination results were normal at biopsy or who showed regression of tumor size and tumor induration after radiation were evaluated. The biopsy results from all patients were combined for analysis. Of 77 patients with negative biopsy specimens 16 (21 per cent) have had recurrent disease, compared to 17 of 26 (65 per cent) with positive biopsy specimens (p equals 0.00005). Of the 77 patients with negative biopsy specimens 7 (9 per cent) had local disease recurrence, compared to 12 of 26 (46 per cent) with a positive biopsy specimen (p equals 0.0001). The value of a positive specimen to predict failure remained significant with patients stratified by pre-treatment clinical stage and grade of the disease. Our results show that patients with positive specimens from the prostate who had been judged clinically by rectal examination to have responded to radiation therapy had a significantly increased incidence of local and distant failure compared to patients who had negative biopsy specimens

  18. Amyloidosis diagnosed in cytology specimen of pleural effusion: A case report.

    Science.gov (United States)

    Manur, Rashmi; Lamzabi, Ihab

    2018-06-01

    Amyloidosis is a rare condition resulting from extracellular deposition of amyloid, a fibrillary material derived from various precursor proteins. Involvement of the pleura by amyloidosis is a rare but serious complication. Pleural amyloidosis is primarily diagnosed by identifying amyloid deposition by histology on pleural biopsy specimens. Hereby, we report a case of systemic amyloidosis where we were able to identify amyloid in a pleural effusion specimen sent for cytopathology evaluation. A 59-year-old male with newly diagnosed multiple myeloma and systemic amyloidosis underwent therapeutic thoracentesis. The H&E stained cell block sections revealed a single, less than one millimeter focus of waxy material surrounded by a rim of reactive mesothelial cells suspicious for amyloid deposit in a background of fibrin, lymphocytes, and reactive mesothelial cells. The focus stained salmon pink with Congo-red special stain and showed apple-green birefringence under polarized light. Our finding suggests that pleural involvement in patients with systemic amyloidosis can be identified on effusion specimens and avert the need for more invasive procedures like pleural or pulmonary parenchymal biopsies. © 2017 Wiley Periodicals, Inc.

  19. Percutaneous biopsy of non-palpable breast lesions with the advanced breast biopsy instrumentation (ABBI): analysis of indication strategies

    International Nuclear Information System (INIS)

    Wedegaertner, U.; Otto, U.; Buitrago-Tellez, C.; Bremerich, J.; Bongartz, G.; Oertli, D.; Torhorst, J.

    2001-01-01

    Purpose: To compare the indications for biopsy with and without the use of the Breast Imaging Reporting and Data System. Material and methods: Biopsies using the ABBI were performed in 62 patients with 64 non-palpable evident mammographic lesions. The initial decision for biopsy was made by non-radiologists due to suspicious microcalcifications (n=53) and masses (n=11). The indication was retrospectively reassessed by adopting the BI-RADS classification by three radiologists in consensus. The positive predictive value (PPV) of both indication strategies was assessed and compared. Results: Biopsies adopting ABBI were performed without major side-effects and were diagnostic. Carcinoma was present in 14 lesions: nine specimens were diagnosed as DCIS and five as invasive carcinomas. For the 50 benign lesions histology revealed mastopathies (26/50) and fibroadenomas (8/50) as the most frequent diagnosis. The positive predictive value (PPV) for the initial indication was 22%, whereas PPV for BI-RADS based indications (categories 4 and 5) was 31%. Conclusion: ABBI enables stereotactically-guided procedures that result in representative and diagnostic biopsies. Standardized criteria like BI-RADS improve the PPV and should be a mandatory part of mammographic evaluation. Radiologists should remain involved in the decision making. (orig.) [de

  20. Retroperitoneoscopic renal biopsy in children

    Directory of Open Access Journals (Sweden)

    Carlos M. Jesus

    2007-08-01

    Full Text Available OBJECTIVE: We present our experience in a series of 17 consecutive pediatric patients submitted to retroperitoneal laparoscopic renal biopsy. MATERIALS AND METHODS: Retroperitoneal laparoscopic renal biopsy (LRB was performed in 5 boys and 12 girls. Mean age was 8.1 years and age range from 2 to 12. Two or three trocars were used to expose the inferior pole of the kidney, remove enough cortical parenchymal specimen and fulgurate the biopsy site. Assessment included surgical time, estimated blood loss, hospitalization period, analgesia requirements, complications and number of glomeruli present in the specimen. RESULTS: LRB was successfully performed in all 15 patients (88%. In two cases, LRB was not possible to be performed. One patient was converted to a transperitoneal laparoscopy due to tear in the peritoneum. The other patient had had previous abdominal surgery and, during retroperitoneal balloon dilation, the peritoneum was opened and the open biopsy was performed. A third patient had postoperatively a perirenal hematoma, which was solved spontaneously. Complication rate was 17.6% (3/17 cases. Mean operative time was 65 minutes, while mean estimated blood loss was 52 mL, mean hospital stay was 2.2 days and mean analgesic requirement was 100 mg of tramadol. The mean number of glomeruli present in the specimen was 60. CONCLUSION: Retroperitoneal laparoscopic renal biopsy in children is a simple, safe. Bleeding is still the most common complication. However, direct vision usually allows a safe control of this drawback. In our institution, laparoscopic approach is the chosen procedure in pediatric patients older than one - year - old.

  1. Usefulness of the coaxial technique in US-guided breast core biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong Hyun; Lee, Jeong Hwa; Ha, Jeon Ju; Lee, Keon; Kim, Won Ho; Kwon, Jung Hyeok [Dongkang general hospital, Seoul (Korea, Republic of); Ham, Soo Youn [Ulsan Univ. Hospital, Ulsan (Korea, Republic of)

    1999-05-01

    To evaluate the usefulness of the coaxial technique in US-guided breast core biopsy. Using the coaxial technique, US-guided breast core biopsy was performed in 49 breast lesions (40 patients). Under US-guidance the 17-gauge, 13 cm long introducer needle was positioned proximal to the lesion. Once the needle was in place, the central trocar was removed and was replaced with the core biopsy needle. We used an 18-gauge, 16-cm-long core biopsy needle with a 17 mm specimen notch. Four to eight tissue specimens were obtained from each lesion, and the quality and quantity of specimens, procedure time, and complications and their rate were evaluated. For 48 of 49 lesions, specimens were adequate for histopathologic diagnosis, and the findings were as follows : six cases of invasive ductal carcinoma, one of ductal carcinoma in situ, 29 of fibrocystic disease, eight of fibroadenoma, two of chronic inflammation, and two of sclerosing lesion. In 12 lesions agreement between the pathologic results of needle core biopsy and surgical results was 100%. The procedure time was about 15 minutes and no significant complications were noted. In breast core biopsy, the coaxial technique is simple and time-saving, and compared with standard breast core biopsy, may also be less traumatic and decrease the potential risk of seeding the biopsy tract with malignant cells.

  2. Usefulness of the coaxial technique in US-guided breast core biopsy

    International Nuclear Information System (INIS)

    Kim, Dong Hyun; Lee, Jeong Hwa; Ha, Jeon Ju; Lee, Keon; Kim, Won Ho; Kwon, Jung Hyeok; Ham, Soo Youn

    1999-01-01

    To evaluate the usefulness of the coaxial technique in US-guided breast core biopsy. Using the coaxial technique, US-guided breast core biopsy was performed in 49 breast lesions (40 patients). Under US-guidance the 17-gauge, 13 cm long introducer needle was positioned proximal to the lesion. Once the needle was in place, the central trocar was removed and was replaced with the core biopsy needle. We used an 18-gauge, 16-cm-long core biopsy needle with a 17 mm specimen notch. Four to eight tissue specimens were obtained from each lesion, and the quality and quantity of specimens, procedure time, and complications and their rate were evaluated. For 48 of 49 lesions, specimens were adequate for histopathologic diagnosis, and the findings were as follows : six cases of invasive ductal carcinoma, one of ductal carcinoma in situ, 29 of fibrocystic disease, eight of fibroadenoma, two of chronic inflammation, and two of sclerosing lesion. In 12 lesions agreement between the pathologic results of needle core biopsy and surgical results was 100%. The procedure time was about 15 minutes and no significant complications were noted. In breast core biopsy, the coaxial technique is simple and time-saving, and compared with standard breast core biopsy, may also be less traumatic and decrease the potential risk of seeding the biopsy tract with malignant cells

  3. Automated gun biopsy of the prostate under ultrasound guide

    International Nuclear Information System (INIS)

    Yang, Ik; Lim, Jae Hoon; Ko, Young Tae; Lee, Dong Ho; Lim, Joo Won

    1994-01-01

    To assess the effectiveness and clinical usefulness of prostate biopsy by automated gun biopsy device under the transrectal ultrasonographic guidance, authors analysed the result of biopsy and the patients status after biopsy procedure. The subjects consisted of 24 patients with prostatic disease. Biopsy instrument was an automated gun biopsy device loaded with an 18 gauze biopsy needle. All the patients were admitted to the hospital. No analgesics was given. All the procedure was performed with the patient in left lateral decubitus. Biopsy was performed at 2-4 different points of the prostate in 22 cases, but recently, six different points were targeted in two patients. Biopsy specimens were sufficient in 21 cases but insufficient in three cases. Histologic examination of biopsy specimens showed that 13 cases were nodular hyperplasia, eight cases were cancerous and three cases were inflammation. There was no clinically significant complication. There was mild to moderate degree of pain in all patients. Tansrectal biopsy of the prostate with an automated gun biopsy device under ultrasonographic guidance is considered relatively easy, handy and useful procedure in patients with prostatic disease. The procedure may be performed on the out patient basis

  4. US-guided biopsy of renal allografts using 18G biopsy gun: analysis of 200 cases

    International Nuclear Information System (INIS)

    Kim, Eun Kyung; Lee, Jong Tae; Kim, Myeong Jin; Yoo, Hyung Sik; Kim, Ki Whang; Park, Ki Ill; Chung, Hyun Joo

    1995-01-01

    We evaluated the effectiveness and safety of 18G biopsy gun with US guidance in the transplanted kidneys. We performed 200 US-guided percutaneous biopsies using 18G biopsy gun. Diagnostic efficacy and complication of the biopsy in these patients were analyzed. Biopsy specimens were adequate for histologic diagnoses in 193 patients(96.5%). The mean of the biopsy frequency was 3, the mean of total glomerular number was 21.64 and the mean glomerular number per one biopsy was 6.93. Major complications occurred in 3 (1.5%) of the 200 biopsies; hematuria developed in two patients, AV fistula in one. These complications were successfully controlled either by only transfusion or by coil embolization. There were no statistical differences in blood pressure, hemoglobin, BUN/Cr between pre-and post-renal biopsies. US-guided percutaneous biopsy of renal allograft with 18G biopsy gun is simple, safe, and accurate method in evaluating the renal allograft dysfunction

  5. Usefulness of US-guided automated gun biopsy of nonpalpable breast lesions

    Energy Technology Data Exchange (ETDEWEB)

    Kwak, Min Sook; Kim, Hak Soo; Lee, Han Kyung; Koh, Sung Hye; O, Eun Young; Yoon, Myung Hwan; Yang, Dal Mo; Kim, Hyung Sik [Chungang Gil Hospital, Incheon (Korea, Republic of)

    1997-11-01

    To evaluate the clinical usefulness of ultrasonography(US)-guided automated gun biopsy of nonpalpable breast lesions. In 30 nonpalpable breast lesions over 0.6cm and detected on US, we performed US-guided biopsy using an 18-gauge automated biopsy gun. Two to four specimens were obtained from each lesion. We analyzed the site, size and depth of the lesions, and the length and histopathologic results of the specimens. In four lesions, surgical biopsy and gun biopsy results were compared. In 29 of 30 lesions(96.7%), specimens were adequate for histopathologic diagnosis, and this was as follows : one case of infiltrating ductal carcinoma, 13 of fibrocystic disease, 10 of fibrocystic disease versus fibroadenoma and one of fibrodenoma. There was also one reactive hyperplasia of LN, and one fatty one and two normal tissues, and in these four lesions, agreement between gun and surgical biopsy results was 100%. The only complication was minor bleeding, which was controlled by compression. US-guided automated gun biopsy is a clinically useful and safe procedure for evaluating nonpalpable breast lesions detected on US.

  6. Usefulness of US-guided automated gun biopsy of nonpalpable breast lesions

    International Nuclear Information System (INIS)

    Kwak, Min Sook; Kim, Hak Soo; Lee, Han Kyung; Koh, Sung Hye; O, Eun Young; Yoon, Myung Hwan; Yang, Dal Mo; Kim, Hyung Sik

    1997-01-01

    To evaluate the clinical usefulness of ultrasonography(US)-guided automated gun biopsy of nonpalpable breast lesions. In 30 nonpalpable breast lesions over 0.6cm and detected on US, we performed US-guided biopsy using an 18-gauge automated biopsy gun. Two to four specimens were obtained from each lesion. We analyzed the site, size and depth of the lesions, and the length and histopathologic results of the specimens. In four lesions, surgical biopsy and gun biopsy results were compared. In 29 of 30 lesions(96.7%), specimens were adequate for histopathologic diagnosis, and this was as follows : one case of infiltrating ductal carcinoma, 13 of fibrocystic disease, 10 of fibrocystic disease versus fibroadenoma and one of fibrodenoma. There was also one reactive hyperplasia of LN, and one fatty one and two normal tissues, and in these four lesions, agreement between gun and surgical biopsy results was 100%. The only complication was minor bleeding, which was controlled by compression. US-guided automated gun biopsy is a clinically useful and safe procedure for evaluating nonpalpable breast lesions detected on US

  7. Fluoroscopy-guided transnasal biopsy of nasopharyngeal carcinoma using a flexible bronchoscopic biopsy forcep

    International Nuclear Information System (INIS)

    Kim, Jai Keun; Chung, Tae Sub; Kim, Dong Ik; Suh, Jung Ho

    1996-01-01

    Otolaryngoscopic biopsy of nasopharyngeal carcinoma is a generalized method which may be associated with inadequate sampling of tissue and patient discomfort. So, we tried fluoroscopy-guided transnasal biopsy using bronchoscopic biopsy forcep and evaluated its safety and efficacy. Prospectively we performed fluoroscopy-guided transnasal biopsy in 11 patients who were radiographically suspected of nasopharyngeal carcinoma. The posterior wall of the nasopharynx was coated with barium sulfate under fluoroscopy. A flexible bronchoscopic biopsy forcep with a steerable guiding catheter which was used in removal of intrahepatic duct stones was inserted through the nare. After localization of the tip of the biopsy forcep at tumor site with fluoroscopy, a tissue specimen was obtained. We also tried CT guided biopsy in initial 2cases. Each patient had otolaryngoscopic biopsy to compare the biopsy result and patient discomfort. We could have sufficient amount of tissue for pathological evaluation in 10 of 11 patients by the first pass with the fluoroscopic technique. Contrarily, otolaryngoscopic biopsy was successful in 7 of 11 patients on single passage. Additionally, 2 patients had complaint in our method comparing with 9 patients in otolaryngoscopic biopsy. Fluoroscopy-guided transnasal biopsy of nasopharyngeal carcinoma using the bronchoscopic biopsy forcep is safe and accurate. It can be a appropriate method competing otolaryngoscopic biopsy

  8. Evaluation of lymphocytic exudative pleural effusion with pleural biopsy

    International Nuclear Information System (INIS)

    Khurram, M.; Jaffery, A.H.; Khar, Hamama-tul-Bushra; Malik, M.F.; Javed, S.; Burki, U.F.; Khan, B.A.; Ali, A.

    2002-01-01

    Objective: Evaluation of lymphocytic exudative pleural effusion by histopathological examination of pleural biopsy in patients with suspected tuberculous or malignant pleural effusion. Place and Duration of Study: The study was conducted at Pulmonology Department, Pakistan Institute of Medical Sciences, Islamabad and DHQ Teaching Hospital, Rawalpindi for two years 1999-2000. Subjects and Methods: A total of 120 patients with exudative pleural effusion underwent closed pleural biopsy with Abram's needle in standard way. Average 4 biopsy specimens were obtained in each patient which were examined histopathologically. Patients in whom a definite diagnosis was not possible were further investigated with repeat pleural biopsy, sputum examinations, bronchoscopy etc. Results definite histopathological diagnosis with pleural biopsy was possible in 59 (49.16% patients, including 13 diagnosed on repeat pleural biopsy. Two commonest diagnoses made were tuberculosis and adenocarcinoma, 64.40% and 13.55% respectively. Conclusion: Histopathological evaluation of pleural biopsy specimens can lead to diagnosis in 49.16% patients with exudative lymphocytic pleural effusion. (author)

  9. [Muscle biopsy in children: Usefulness in 2012].

    Science.gov (United States)

    Cuisset, J-M; Maurage, C-A; Carpentier, A; Briand, G; Thévenon, A; Rouaix, N; Vallée, L

    2013-01-01

    Muscle biopsy is a mainstay diagnostic tool for investigating neuromuscular disorders in children. We report the yield of pediatric muscle biopsy in a population of 415 children by a retrospective study of 419 biopsies performed between 1/01/2000 and 31/12/2009 in a neuropediatric department, including mitochondrial respiratory chain analysis for 87 children. Two hundred and fifty-five biopsies were from boys (61%) 164 from girls (39%). Their mean age at biopsy was 6.5years; 155 (37%) biopsies were obtained before the child was 5years old. Final histopathological diagnoses were: congenital myopathy (n=193, including 15 structural congenital myopathies); progressive muscular dystrophy (n=75 [18%] including 57 dystrophinopathies); congenital muscular dystrophy (n=17, including six primary merosinopathies); dermatomyositis (n=11); spinal muscular atrophy (n=9, including six atypical spinal muscular atrophies); metabolic myopathy (n=32, including 19 mitochondrial myopathies); encephalomyopathy (n=53 [13%], including 27 with a mitochondrial respiratory chain defect). Pathological diagnosis remained undetermined in 16 cases. In 184 patients (44%), the muscle biopsy revealed specific histopathological anomalies (dystrophic process; specific ultrastructural abnormalities; perifascicular atrophy; neurogenic atrophy; metabolic anomalies) enabling a precise etiological diagnosis. For 85% of progressive muscular dystrophies, the biopsy resulted in a genetic diagnosis after identification of the protein defect. In 15% of the congenital myopathies, histopathological anomalies focused attention on one or several genes. Concerning dystrophinopathies, quantification of dystrophin deficiency on the biopsy specimen contributed to the definition of the clinical phenotype: Duchenne, or Becker. In children with a myopathy, muscle biopsy is often indispensable to establish the etiological diagnosis. Based on the results from this series, muscle biopsy can provide a precise

  10. THE ANTI-TB DRUG SENSITIVITY OF MYCOBACTERIUM TUBERCULOSIS FROM CEREBROSPINAL FLUID AND BONE TISSUE BIOPSY SPECIMENS OF PATIENTS SUSPECTED TUBERCULOUS MENINGITIS AND SPINAL TB IN DR SOETOMO HOSPITAL INDONESIA

    Directory of Open Access Journals (Sweden)

    Ni Made Mertaniasih

    2014-09-01

    Full Text Available Tuberculous meningitis (TBM is an infection of meningens which potentially life threatening with significant morbidity and mortality. Spinal TB has the same problem with TBM, infection in bone and joint, the delayed diagnosis worsens the prognosis. The rapid and accurate diagnosis plus promt adequate treatment is essential for the good outcome. The aim of this research is to study the first line drug sensitivity of Mycobacterium tuberculosis isolated from specimens of cerebrospinal fluid from suspected tuberculous meningitis patients and bone tissue biopsy from suspected spinal TB patients. The method of this research is TB Laboratory examination in Department of Clinical Microbiology – Dr. Soetomo General Hospital, Indonesia, using the gold standard liquid culture method MGIT 960 System (Becton Dickinson and solid culture method with Lowenstein-Jensen medium. The specimens CSF from 50 TBM patients at January 2013 until May 2014. Positive isolate detection of Mycobacterium tuberculosis complex were 11 isolates (22%, which sensitivity 100% (11/11 isolates to Rifampin (R, Pyrazinamide (Z, Ethambutol (E, and Streptomycin (S; one isolate resistant to Isoniazid, sensitivity to Isoniazid 90,90% (10/11; and received 21 specimens of bone tissue biopsy which positive 5 isolates (23%, all isolates sensitive 100% (5/5 isolates to Rifampin and Pyrazinamide, and 1 isolates resistant to Isoniazid, Ethambutol, and Streptomycin, in which sensitivity 80% (4/5 isolates to Isoniazid, Ethambutol, and Streptomycin. The conclusion of this research is positivity detection 22% of CSF specimens, and 23% of bone tissue biopsy were low. All isolates sensitive 100% to Rifampin and Pyrazinamide, and 80-90% sensitive to Isoniazid.

  11. Powered bone marrow biopsy procedures produce larger core specimens, with less pain, in less time than with standard manual devices

    Directory of Open Access Journals (Sweden)

    Larry J. Miller

    2011-07-01

    Full Text Available Bone marrow sampling remains essential in the evaluation of hematopoietic and many non-hematopoietic disorders. One common limitation to these procedures is the discomfort experienced by patients. To address whether a Powered biopsy system could reduce discomfort while providing equivalent or better results, we performed a randomized trial in adult volunteers. Twenty-six subjects underwent bilateral biopsies with each device. Core samples were obtained in 66.7% of Manual insertions; 100% of Powered insertions (P=0.002. Initial mean biopsy core lengths were 11.1±4.5 mm for the Manual device; 17.0±6.8 mm for the Powered device (P<0.005. Pathology assessment for the Manual device showed a mean length of 6.1±5.6 mm, width of 1.0±0.7 mm, and volume of 11.0±10.8 mm3. Powered device measurements were mean length of 15.3±6.1 mm, width of 2.0±0.3 mm, and volume of 49.1±21.5 mm3 (P<0.001. The mean time to core ejection was 86 seconds for Manual device; 47 seconds for the Powered device (P<0.001. The mean second look overall pain score was 33.3 for the Manual device; 20.9 for the Powered (P=0.039. We conclude that the Powered biopsy device produces superior sized specimens, with less overall pain, in less time.

  12. Does imprint cytology improve the accuracy of transrectal prostate needle biopsy?

    Science.gov (United States)

    Sayar, Hamide; Bulut, Burak Besir; Bahar, Abdulkadir Yasir; Bahar, Mustafa Remzi; Seringec, Nurten; Resim, Sefa; Çıralık, Harun

    2015-02-01

    To evaluate the accuracy of imprint cytology of core needle biopsy specimens in the diagnosis of prostate cancer. Between December 24, 2011 and May 9, 2013, patients with an abnormal DRE and/or serum PSA level of >2.5 ng/mL underwent transrectal prostate needle biopsy. Samples with positive imprint cytology but negative initial histologic exam underwent repeat sectioning and histological examination. 1,262 transrectal prostate needle biopsy specimens were evaluated from 100 patients. Malignant imprint cytology was found in 236 specimens (18.7%), 197 (15.6%) of which were confirmed by histologic examination, giving an initial 3.1% (n = 39) rate of discrepant results by imprint cytology. Upon repeat sectioning and histologic examination of these 39 biopsy samples, 14 (1.1% of the original specimens) were then diagnosed as malignant, 3 (0.2%) as atypical small acinar proliferation (ASAP), and 5 (0.4%) as high-grade prostatic intraepithelial neoplasia (HGPIN). Overall, 964 (76.4%) specimens were negative for malignancy by imprint cytology. Seven (0.6%) specimens were benign by cytology but malignant cells were found on histological evaluation. On imprint cytology examination, nonmalignant but abnormal findings were seen in 62 specimens (4.9%). These were all due to benign processes. After reexamination, the accuracy, sensitivity, specificity, positive predictive value, negative predictive value, false-positive rate, false-negative rate of imprint preparations were 98.1, 96.9, 98.4, 92.8, 99.3, 1.6, 3.1%, respectively. Imprint cytology is valuable tool for evaluating TRUS-guided core needle biopsy specimens from the prostate. Use of imprint cytology in combination with histopathology increases diagnostic accuracy when compared with histopathologic assessment alone. © 2014 Wiley Periodicals, Inc.

  13. False-negative results of breast core needle biopsies - retrospective analysis of 988 biopsies

    International Nuclear Information System (INIS)

    Boba, M.; Koltun, U.; Bobek-Billewicz, B.; Eksner, B.; Olejnik, T.; Chmielik, E.

    2011-01-01

    Background: Breast cancer is the most common malignant neoplasm and the most common cause of death among women. The core needle biopsy is becoming a universal practice in diagnosing breast lesions suspected of malignancy. Unfortunately, breast core needle biopsies also bear the risk of having false-negative results. Material/Methods: 988 core needle breast biopsies were performed at the Maria Sklodowska-Curie Memorial Cancer Center and Institute of Oncology, Gliwice Branch, between 01 March 2006 and 29 February 2008. Malignant lesions were diagnosed in 426/988 (43.12%) cases, atypical hyperplasia in 69/988 (6.98%), and benign lesions in 493/988 (49.90%) cases. Results: Twenty-two out of 988 biopsies (2.23%) were found to be false negative. Histopathological assessment of tissue specimens was repeated in these cases. In 14/22 (64%) cases, the previous diagnosis of a benign lesion was changed. In 8/22 (36%) cases, the diagnosis of a benign lesion was confirmed. False-negative rate was calculated at 2.2%. The rate of false-negative diagnoses resulting from a radiological mistake was estimated at 36%. The rate of false-negative diagnoses, resulting from histopathological assessment, was 64%. False-negative results caused by a radiological error comprised 1.5% of all histopathologically diagnosed cancers and atypias (sensitivity of 98.5%). There were no false-positive results in our material - the specificity of the method was 100%. Conclusions: Histopathological interpretation is a substantial cause of false-negative results of breast core needle biopsy. Thus, in case of a radiological-histopathological divergence, histopathological analysis of biopsy specimens should be repeated. The main radiological causes of false-negative results of breast core needle biopsy are as follows: sampling from an inappropriate site and histopathological non-homogeneity of cancer infiltration. (authors)

  14. Infective endocarditis with spondylodiscitis after prostate biopsy

    Directory of Open Access Journals (Sweden)

    Fernando Pivatto Júnior

    2014-04-01

    Full Text Available Transrectal ultrasonography-guided prostate needle biopsy is the ideal method to obtain prostate specimens for histological analysis and is therefore frequently used in clinical practice. In the majority of the studies, prostate biopsy is considered a safe procedure with few major complications. In the present report, we describe a case of endocarditis with spondylodiscitis, two very rare complications of prostate biopsy.

  15. The 3DBiopsy Prostate Biopsy System: Preclinical Investigation of a Needle, Actuator, and Specimen Collection Device Allowing Sampling of Individualized Prostate Lengths Between 20 and 60 mm.

    Science.gov (United States)

    Stone, Nelson N; Mouraviev, Vladimir; Schechter, David; Lucia, M Scott; Smith, Elizabeth E; Arangua, Paul; Hoenemeyer, John; Rosa, Jim; Bawa, Rajan; Crawford, E David

    2017-09-01

    To increase the likelihood of detecting anterior cancers within the prostate and provide a specimen that spans the length of the gland. Newly designed 17- and 15-gauge (G) biopsy needles, a variable actuator, and an integrated pathology system intended for the longer cores were developed and tested for this purpose. Testing was performed comparing 2 common cannula tip grinds, a Vet-point (sharp tip) and a Menghini-point (atraumatic tip), and were tested against 18-G Bard Monopty in porcine kidney. A variable actuator was developed to fire the needle 20-60 mm and tested in cadaver prostates. The aggregate firings for 3 different shot lengths comparing the Vet- with the Menghini-tip cannulas demonstrated 91% vs 85.2% fill (length of specimen/length of core bed, P = .007). A 15-G trocar needle with the Vet-tip cannula also had the best performance, with an aggregate standard deviation of 6.4% across 3 firing ranges and a minimum to maximum specimen length of 81%-105% of potential fill. Cadaver testing with the Vet-tip needles in the actuator for the transrectal (17-G) and transperineal (15-G) biopsies demonstrated mean fills of 93.3% and 76.5%, respectively. The new transrectal ultrasound needle obtained a 2-fold increase in specimen length over the standard Bard device (P actuator, the physician can obtain specimens that include peripheral and anterior zone tissue in 1 core. Determination of cancer location on the longer specimens could enhance focal therapy planning. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Importance of prostate-specific antigen (PSA as a predictive factor for concordance between the Gleason scores of prostate biopsies and RADICAL prostatectomy specimens

    Directory of Open Access Journals (Sweden)

    Nelson Gianni de Lima

    2013-06-01

    Full Text Available OBJECTIVE: To evaluate the concordance between the Gleason scores of prostate biopsies and radical prostatectomy specimens, thereby highlighting the importance of the prostate-specific antigen (PSA level as a predictive factor of concordance. METHODS: We retrospectively analyzed 253 radical prostatectomy cases performed between 2006 and 2011. The patients were divided into 4 groups for the data analysis and dichotomized according to the preoperative PSA, <10 ng/mL and ≥10 ng/mL. A p-score <0.05 was considered significant. RESULTS: The average patient age was 63.3±7.8 years. The median PSA level was 9.3±4.9 ng/mL. The overall concordance between the Gleason scores was 52%. Patients presented preoperative PSA levels <10 ng/mL in 153 of 235 cases (65% and ≥10 ng/mL in 82 of 235 cases (35%. The Gleason scores were identical in 86 of 153 cases (56% in the <10 ng/mL group and 36 of 82 (44% cases in the ≥10 ng/mL group (p = 0.017. The biopsy underestimated the Gleason score in 45 (30% patients in the <10 ng/mL group and 38 (46% patients in the ≥10 ng/mL (p = 0.243. Specifically, the patients with Gleason 3 + 3 scores according to the biopsies demonstrated global concordance in 56 of 110 cases (51%. In this group, the patients with preoperative PSA levels <10 ng/dL had higher concordance than those with preoperative PSA levels ≥10 ng/dL (61% x 23%, p = 0.023, which resulted in 77% upgrading after surgery in those patients with PSA levels ≥10 ng/dl. CONCLUSION: The Gleason scores of needle prostate biopsies and those of the surgical specimens were concordant in approximately half of the global sample. The preoperative PSA level was a strong predictor of discrepancy and might improve the identification of those patients who tended to be upgraded after surgery, particularly in patients with Gleason scores of 3 + 3 in the prostate biopsy and preoperative PSA levels ≥10 ng/mL.

  17. Fluoroscopy-Guided Percutaneous Vertebral Body Biopsy Using a Novel Drill-Powered Device: Technical Case Series

    International Nuclear Information System (INIS)

    Wallace, Adam N.; Pacheco, Rafael A.; Tomasian, Anderanik; Hsi, Andy C.; Long, Jeremiah; Chang, Randy O.; Jennings, Jack W.

    2016-01-01

    BackgroundA novel coaxial biopsy system powered by a handheld drill has recently been introduced for percutaneous bone biopsy. This technical note describes our initial experience performing fluoroscopy-guided vertebral body biopsies with this system, compares the yield of drill-assisted biopsy specimens with those obtained using a manual technique, and assesses the histologic adequacy of specimens obtained with drill assistance.MethodsMedical records of all single-level, fluoroscopy-guided vertebral body biopsies were reviewed. Procedural complications were documented according to the Society of Interventional Radiology classification. The total length of bone core obtained from drill-assisted biopsies was compared with that of matched manual biopsies. Pathology reports were reviewed to determine the histologic adequacy of specimens obtained with drill assistance.ResultsTwenty eight drill-assisted percutaneous vertebral body biopsies met study inclusion criteria. No acute complications were reported. Of the 86 % (24/28) of patients with clinical follow-up, no delayed complications were reported (median follow-up, 28 weeks; range 5–115 weeks). The median total length of bone core obtained from drill-assisted biopsies was 28 mm (range 8–120 mm). This was longer than that obtained from manual biopsies (median, 20 mm; range 5–45 mm; P = 0.03). Crush artifact was present in 11 % (3/28) of drill-assisted biopsy specimens, which in one case (3.6 %; 1/28) precluded definitive diagnosis.ConclusionsA drill-assisted, coaxial biopsy system can be used to safely obtain vertebral body core specimens under fluoroscopic guidance. The higher bone core yield obtained with drill assistance may be offset by the presence of crush artifact

  18. Fluoroscopy-Guided Percutaneous Vertebral Body Biopsy Using a Novel Drill-Powered Device: Technical Case Series

    Energy Technology Data Exchange (ETDEWEB)

    Wallace, Adam N., E-mail: wallacea@mir.wustl.edu; Pacheco, Rafael A., E-mail: pachecor@mir.wustl.edu; Tomasian, Anderanik, E-mail: tomasiana@mir.wustl.edu [Washington University School of Medicine, Mallinckrodt Institute of Radiology (United States); Hsi, Andy C., E-mail: hsia@path.wustl.edu [Washington University School of Medicine, Division of Anatomic Pathology, Department of Pathology & Immunology (United States); Long, Jeremiah, E-mail: longj@mir.wustl.edu [Washington University School of Medicine, Mallinckrodt Institute of Radiology (United States); Chang, Randy O., E-mail: changr@wusm.wustl.edu [Washington University School of Medicine (United States); Jennings, Jack W., E-mail: jenningsj@mir.wustl.edu [Washington University School of Medicine, Mallinckrodt Institute of Radiology (United States)

    2016-02-15

    BackgroundA novel coaxial biopsy system powered by a handheld drill has recently been introduced for percutaneous bone biopsy. This technical note describes our initial experience performing fluoroscopy-guided vertebral body biopsies with this system, compares the yield of drill-assisted biopsy specimens with those obtained using a manual technique, and assesses the histologic adequacy of specimens obtained with drill assistance.MethodsMedical records of all single-level, fluoroscopy-guided vertebral body biopsies were reviewed. Procedural complications were documented according to the Society of Interventional Radiology classification. The total length of bone core obtained from drill-assisted biopsies was compared with that of matched manual biopsies. Pathology reports were reviewed to determine the histologic adequacy of specimens obtained with drill assistance.ResultsTwenty eight drill-assisted percutaneous vertebral body biopsies met study inclusion criteria. No acute complications were reported. Of the 86 % (24/28) of patients with clinical follow-up, no delayed complications were reported (median follow-up, 28 weeks; range 5–115 weeks). The median total length of bone core obtained from drill-assisted biopsies was 28 mm (range 8–120 mm). This was longer than that obtained from manual biopsies (median, 20 mm; range 5–45 mm; P = 0.03). Crush artifact was present in 11 % (3/28) of drill-assisted biopsy specimens, which in one case (3.6 %; 1/28) precluded definitive diagnosis.ConclusionsA drill-assisted, coaxial biopsy system can be used to safely obtain vertebral body core specimens under fluoroscopic guidance. The higher bone core yield obtained with drill assistance may be offset by the presence of crush artifact.

  19. False-negative results of breast core needle biopsies – retrospective analysis of 988 biopsies

    International Nuclear Information System (INIS)

    Boba, Marek; Kołtun, Urszula; Bobek-Billewicz, Barbara; Chmielik, Ewa; Eksner, Bartosz; Olejnik, Tomasz

    2011-01-01

    Breast cancer is the most common malignant neoplasm and the most common cause of death among women. The core needle biopsy is becoming a universal practice in diagnosing breast lesions suspected of malignancy. Unfortunately, breast core needle biopsies also bear the risk of having false-negative results. 988 core needle breast biopsies were performed at the Maria Skłodowska-Curie Memorial Cancer Center and Institute of Oncology, Gliwice Branch, between 01 March 2006 and 29 February 2008. Malignant lesions were diagnosed in 426/988 (43.12%) cases, atypical hyperplasia in 69/988 (6.98%), and benign lesions in 493/988 (49.90%) cases. Twenty-two out of 988 biopsies (2.23%) were found to be false negative. Histopathological assessment of tissue specimens was repeated in these cases. In 14/22 (64%) cases, the previous diagnosis of a benign lesion was changed. In 8/22 (36%) cases, the diagnosis of a benign lesion was confirmed. False-negative rate was calculated at 2.2%. The rate of false-negative diagnoses resulting from a radiological mistake was estimated at 36%. The rate of false-negative diagnoses, resulting from histopathological assessment, was 64%. False-negative results caused by a radiological error comprised 1.5% of all histopathologically diagnosed cancers and atypias (sensitivity of 98.5%). There were no false-positive results in our material - the specificity of the method was 100%. Histopathological interpretation is a substantial cause of false-negative results of breast core needle biopsy. Thus, in case of a radiological-histopathological divergence, histopathological analysis of biopsy specimens should be repeated. The main radiological causes of false-negative results of breast core needle biopsy are as follows: sampling from an inappropriate site and histopathological non-homogeneity of cancer infiltration

  20. When size matters: diagnostic value of kidney biopsy according to the gauge of the biopsy needle.

    Science.gov (United States)

    Roth, Rachel; Parikh, Samir; Makey, Dayanand; Foster, Jamison; Rozenblit, Grigory; Satoskar, Anjali; Nadasdy, Gyongyi; Von Visger, Jon; Hebert, Lee; Rovin, Brad H; Nadasdy, Tibor; Brodsky, Sergey V

    2013-01-01

    Kidney biopsy is a vital tool in the diagnosis of kidney disease. Although it has become a routine procedure, it is not complication-free. Some serious complications of percutaneous kidney biopsy include retroperitoneal hemorrhage and death. There is an increased belief that smaller biopsy needle size results in a lower complication rate. As renal pathologists, we witness an increased number of kidney biopsies performed with a small needle size (as low as gauge 22), which results in inadequate tissue sampling and often non-diagnostic biopsy results. Herein we report the diagnostic value of kidney biopsies according to the size of the biopsy needles. We performed kidney biopsies from nephrectomy specimens using biopsy needles of different sizes. Morphologic parameters were analyzed. We found that biopsies performed by small needles (gauges 20 and 22) contain significantly lower numbers of glomeruli and blood vessels, which limits pathologic evaluation. Data from our institution do not show differences in kidney biopsy complication rates between 16- and 18-gauge needles. Our data indicate that small biopsy needles do not provide sufficient material for diagnosis, and they increase the likelihood for a repeat biopsy. Copyright © 2013 S. Karger AG, Basel.

  1. Clinical application of Lin's biopsy grasper for intrauterine targeted biopsy and polypectomy during office hysteroscopy.

    Science.gov (United States)

    Cheng, Hsin-Yi; Lin, Bao-Liang; Tseng, Jen-Yu; Ueno, Kazunori; Nakada, Sakura

    2018-06-01

    Hysteroscopy has widely been used for diagnosis of the uterine cavity; however, target biopsy has often been difficult in part to the inherent limitations of ancillary instruments. Lin's biopsy grasper was specifically designed to work in conjunction with a flexible hysteroscope to obtain intrauterine biopsy under transabdominal sonography. Herein, we share our clinical experience in the management of endometrial abnormalities with the use of Lin's biopsy grasper during office-based hysteroscopy. From February 2006 to November 2016, the use of Lin's biopsy grasper for tissue biopsy was attempted on 126 cases. We retrospectively recorded and analyzed the patients' preoperative characteristics and biopsy outcomes to demonstrate the feasibility and efficacy of Lin's biopsy grasper. Out of the one hundred and twenty-six enrolled patients, satisfactory targeted biopsies were achieved; including high diagnostic rate (92.1%, with 116 cases confirmed histologically) and adequate tissue retrieval (77.8%, with 98 cases obtaining optimal specimen volume). All patients tolerated the procedure without analgesics or anesthesia. Diagnostic flexible hysteroscopy combined with the use of Lin's biopsy grasper has proven to be an effective tool for intrauterine evaluation and obtaining tissue sample. Copyright © 2018. Published by Elsevier B.V.

  2. Computed tomography-guided percutaneous biopsy of pancreatic masses using pneumodissection

    Directory of Open Access Journals (Sweden)

    Chiang Jeng Tyng

    2013-06-01

    Full Text Available Objective To describe the technique of computed tomography-guided percutaneous biopsy of pancreatic tumors with pneumodissection. Materials and Methods In the period from June 2011 to May 2012, seven computed tomography-guided percutaneous biopsies of pancreatic tumors utilizing pneumodissection were performed in the authors' institution. All the procedures were performed with an automatic biopsy gun and coaxial system with Tru-core needles. The biopsy specimens were histologically assessed. Results In all the cases the pancreatic mass could not be directly approached by computed tomography without passing through major organs and structures. The injection of air allowed the displacement of adjacent structures and creation of a safe coaxial needle pathway toward the lesion. Biopsy was successfully performed in all the cases, yielding appropriate specimens for pathological analysis. Conclusion Pneumodissection is a safe, inexpensive and technically easy approach to perform percutaneous biopsy in selected cases where direct access to the pancreatic tumor is not feasible.

  3. Computed tomography-guided percutaneous biopsy of pancreatic masses using pneumodissection

    International Nuclear Information System (INIS)

    Tyng, Chiang Jeng; Bitencourt, Almir Galvao Vieira; Almeida, Maria Fernanda Arruda; Barbosa, Paula Nicole Vieira; Martins, Eduardo Bruno Lobato; Junior, Joao Paulo Kawaoka Matushita; Chojniak, Rubens; Coimbra, Felipe Jose Fernandez

    2013-01-01

    Objective: to describe the technique of computed tomography-guided percutaneous biopsy of pancreatic tumors with pneumodissection. Materials and methods: in the period from June 2011 to May 2012, seven computed tomography guided percutaneous biopsies of pancreatic tumors utilizing pneumodissection were performed in the authors' institution. All the procedures were performed with an automatic biopsy gun and coaxial system with Tru-core needles. The biopsy specimens were histologically assessed. Results: in all the cases the pancreatic mass could not be directly approached by computed tomography without passing through major organs and structures. The injection of air allowed the displacement of adjacent structures and creation of a safe coaxial needle pathway toward the lesion. Biopsy was successfully performed in all the cases, yielding appropriate specimens for pathological analysis. Conclusion: Pneumodissection is a safe, inexpensive and technically easy approach to perform percutaneous biopsy in selected cases where direct access to the pancreatic tumor is not feasible. (author)

  4. In vitro culture and characterization of enteric neural precursor cells from human gut biopsy specimens using polymer scaffold.

    Science.gov (United States)

    Krishnamohan, Janardhanam; Senthilnathan, Venugopal S; Vaikundaraman, Tirunelveli Muthiah; Srinivasan, Thangavelu; Balamurugan, Madasamy; Iwasaki, Masaru; Preethy, Senthilkumar; Abraham, Samuel Jk

    2013-08-01

    In vitro expansion and characterization of neural precursor cells from human gut biopsy specimens with or without Hirschsprung's disease using a novel thermoreversible gelation polymer (TGP) is reported aiming at a possible future treatment. Gut biopsy samples were obtained from five patients undergoing gut resection for Hirschsprung's disease (n = 1) or gastrointestinal disorders (n = 4). Cells isolated from the smooth muscle layer and the myenteric plexus were cultured in two groups for 18 to 28 days; Group I: conventional culture as earlier reported and Group II: using TGP scaffold. Neurosphere like bodies (NLBs) were observed in the cultures between 8th to 12th day and H & E staining was positive for neural cells in both groups including aganglionic gut portion from the Hirschsprung's disease patient. Immunohistochemistry using S-100 and neuron specific enolase (NSE) was positive in both groups but the TGP group (Group II) showed more number of cells with intense cytoplasmic granular positivity for both NSE and S-100 compared to Group I. TGP supports the in vitro expansion of human gut derived neuronal cells with seemingly better quality NLBs. Animal Studies can be tried to validate their functional outcome by transplanting the NLBs with TGP scaffolds to see whether this can enhance the outcome of cell based therapies for Hirschsprung's disease.

  5. Screen-film specimen radiography

    International Nuclear Information System (INIS)

    Shepard, S.J.; Hogan, J.; Schreck, B.

    1990-01-01

    This paper reports on the reproducibility and quality of biopsy specimen radiographs, a unique phototimed cabinet x-ray system is being developed. The system utilizes specially modified Kodal Min-R cassettes and will be compatible with current mammographic films. Tube voltages are in the 14-20-kVp range with 0.1-1.0-second exposure times. A top-hat type compression device is used (1) to compress the specimen to uniform thickness, (2) to measure the specimen thickness and determine optimum kVp, and (3) to superimpose a grid over the specimen for identification of objects of radiographic interest. The phototiming circuit developed specifically for this purpose will be described along with the modified Min-R cassette. Characteristics of the generator and cabinet will also be described. Tests will be performed on phantoms to evaluate the system limitations

  6. Ultrasound guided needle biopsy of skeletal muscle in neuromuscular disease

    DEFF Research Database (Denmark)

    Lindequist, S; Schrøder, H D; Larsen, C

    1990-01-01

    Guided by ultrasonography percutaneous needle biopsy of skeletal muscle was performed in 24 patients, using the one hand held Biopty system and a 2 mm Tru-Cut needle. The specimens were graded with regard to diagnostic quality and utility and almost all specimens (96%) were of highest quality. Th....... The use of ultrasonography was helpful in selecting a suitable area for the biopsy and vascular structures could be avoided. The procedure was well tolerated and easy to perform, and no complications were recorded....

  7. Evaluation of chronic infectious interstitial pulmonary disease in children by low-dose CT-guided transthoracic lung biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Heyer, Christoph M.; Lemburg, Stefan P.; Kagel, Thomas; Nicolas, Volkmar [Ruhr-University of Bochum, Institute of Diagnostic Radiology, Interventional Radiology and Nuclear Medicine, BG Clinics Bergmannsheil, Bochum (Germany); Mueller, Klaus-Michael [Ruhr-University of Bochum, Institute of Pathology, BG Clinics Bergmannsheil, Bochum (Germany); Nuesslein, Thomas G.; Rieger, Christian H.L. [Ruhr-University of Bochum, Pediatric Hospital, Bochum (Germany)

    2005-07-01

    Children with chronic infectious interstitial lung disease often have to undergo open lung biopsy to establish a final diagnosis. Open lung biopsy is an invasive procedure with major potential complications. Transthoracic lung biopsy (TLB) guided by computed tomography (CT) is a less-invasive well-established procedure in adults. Detailing the role of low-dose CT-guided TLB in the enhanced diagnosis of chronic lung diseases related to infection in children. A group of 11 children (age 8 months to 16 years) underwent CT-guided TLB with a 20-gauge biopsy device. All investigations were done under general anaesthesia on a multidetector CT scanner (SOMATOM Volume Zoom, Siemens, Erlangen, Germany) using a low-dose protocol (single slices, 120 kV, 20 mAs). Specimens were processed by histopathological, bacteriological, and virological techniques. All biopsies were performed without major complications; one child developed a small pneumothorax that resolved spontaneously. A diagnosis could be obtained in 10 of the 11 patients. Biopsy specimens revealed chronic interstitial alveolitis in ten patients. In five patients Chlamydia pneumoniae PCR was positive, in three Mycoplasma pneumoniae PCR was positive, and in two Cytomegalovirus PCR was positive. The average effective dose was 0.83 mSv. Low-dose CT-guided TLB can be a helpful tool in investigating chronic infectious inflammatory processes in children with minimal radiation exposure. It should be considered prior to any open surgical procedure performed for biopsy alone. In our patient group no significant complication occurred. A disadvantage of the method is that it does not allow smaller airways and vessels to be assessed. (orig.)

  8. 'Microerosions' in rectal biopsies in Crohn's disease

    DEFF Research Database (Denmark)

    Poulsen, Steen Seier

    1984-01-01

    Small (less than 1 mm), superficial erosions ('microerosions') have been observed stereo-microscopically in surface-stained rectal biopsies in Crohn's disease (CD). Biopsy specimens from 97 patients with CD, 225 with ulcerative colitis (UC), and a control material of 161 patients were investigated....... Granulomas were identified in 62% of the biopsies with microerosions and by examination of two consecutive biopsies from each of these patients, in 85% indicating a positive correlation. In patients with microerosions and a primary diagnosis of UC, granulomas were found in 38% and by examination of two...... biopsies in 54%. Patients with granulomas and a few other patients were reclassified as CD, but there still remained some patients with microerosions, who most probably had UC. In conclusion, microerosions are observed mainly in CD with colonic involvement. There is a high incidence of granulomas in biopsy...

  9. Nail biopsy: A user's manual

    Directory of Open Access Journals (Sweden)

    Chander Grover

    2018-01-01

    Full Text Available Nail biopsy is a procedure not routinely resorted to; but when indicated, it is often the only clue left for diagnosis. At such times, it pays to be conversant with it. It is an investigation that not only provides etiologic, diagnostic, and prognostic information but also aids in understanding the pathogenesis of nail diseases. It can be of therapeutic value, especially with respect to nail tumors. This article compiles the procedural techniques for nail biopsy of various types and attempts to summarize the evidence available in the literature. The objective of nail biopsy is to clinch a precise diagnosis of nail pathology with a simple and safe surgical procedure, avoiding pain or permanent nail damage. Patient selection is of utmost importance, wherein, the patient does not have typical skin lesions, yields inadequate information on routine nail investigations, and has no peripheral vascular compromise. The patient needs to be explained about the risks associated, the expected functional handicap, the time required for regrowth, a possibility of permanent nail dystrophy, and a possibility of not achieving a diagnosis even after the biopsy. Techniques and types of various nail biopsies are being discussed in this article. The specimen could be collected as an excision biopsy, punch biopsy, shave biopsy, or longitudinal biopsy. The trick lies in choosing the appropriate area for biopsy. Various biopsy types discussed in this article include nail plate biopsy (easiest and least scarring; nail bed biopsy (elliptical excision or punch; nail matrix biopsy (elliptical excision, punch excision (≤3 mm or tangential/shave excision; and nail fold biopsy. Complications reported along with means to minimize them are also discussed.

  10. Discordance between location of positive cores in biopsy and location of positive surgical margin following radical prostatectomy.

    Science.gov (United States)

    Kim, Ji Won; Park, Hyoung Keun; Kim, Hyeong Gon; Ham, Dong Yeub; Paick, Sung Hyun; Lho, Yong Soo; Choi, Woo Suk

    2015-10-01

    We compared location of positive cores in biopsy and location of positive surgical margin (PSM) following radical prostatectomy. This retrospective analysis included patients who were diagnosed as prostate cancer by standard 12-core transrectal ultrasonography guided prostate biopsy, and who have PSM after radical prostatectomy. After exclusion of number of biopsy cores location data, 46 patients with PSM were identified. Locations of PSM in pathologic specimen were reported as 6 difference sites (apex, base and lateral in both sides). Discordance of biopsy result and PSM was defined when no positive cores in biopsy was identified at the location of PSM. Most common location of PSM were right apex (n=21) and left apex (n=15). Multiple PSM was reported in 21 specimens (45.7%). In 32 specimens (69.6%) with PSM, one or more concordant positive biopsy cores were identified, but 14 specimens (28%) had no concordant biopsy cores at PSM location. When discordant rate was separated by locations of PSM, right apex PSM had highest rate of discordant (38%). The discordant group had significantly lower prostate volume and lower number of positive cores in biopsy than concordant group. This study showed that one fourth of PSM occurred at location where tumor was not detected at biopsy and that apex PSM had highest rate of discordant. Careful dissection to avoid PSM should be performed in every location, including where tumor was not identified in biopsy.

  11. Ultrasound-guided percutaneous core needle biopsy of abdominal viscera: Tips to ensure safe and effective biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jin Woong; Shin, Sang Soo [Chonnam National University Hospital, Chonnam National University Medical School, Gwangju(Korea, Republic of)

    2017-04-15

    Ultrasound-guided percutaneous core needle biopsy (USPCB) is used extensively in daily clinical practice for the pathologic confirmation of both focal and diffuse diseases of the abdominal viscera. As a guidance tool, US has a number of clear advantages over computerized tomography or magnetic resonance imaging: fewer false-negative biopsies, lack of ionizing radiation, portability, relatively short procedure time, real-time intra-procedural visualization of the biopsy needle, ability to guide the procedure in almost any anatomic plane, and relatively lower cost. Notably, USPCB is widely used to retrieve tissue specimens in cases of hepatic lesions. However, general radiologists, particularly beginners, find USPCB difficult to perform in abdominal organs other than the liver; indeed, a full understanding of the entire USPCB process and specific considerations for specific abdominal organs is necessary to safely obtain adequate specimens. In this review, we discuss some points and techniques that need to be borne in mind to increase the chances of successful USPCB. We believe that the tips and considerations presented in this review will help radiologists perform USPCB to successfully retrieve target tissue from different organs with minimal complications.

  12. Ultrasound-guided percutaneous core needle biopsy of abdominal viscera: Tips to ensure safe and effective biopsy

    International Nuclear Information System (INIS)

    Kim, Jin Woong; Shin, Sang Soo

    2017-01-01

    Ultrasound-guided percutaneous core needle biopsy (USPCB) is used extensively in daily clinical practice for the pathologic confirmation of both focal and diffuse diseases of the abdominal viscera. As a guidance tool, US has a number of clear advantages over computerized tomography or magnetic resonance imaging: fewer false-negative biopsies, lack of ionizing radiation, portability, relatively short procedure time, real-time intra-procedural visualization of the biopsy needle, ability to guide the procedure in almost any anatomic plane, and relatively lower cost. Notably, USPCB is widely used to retrieve tissue specimens in cases of hepatic lesions. However, general radiologists, particularly beginners, find USPCB difficult to perform in abdominal organs other than the liver; indeed, a full understanding of the entire USPCB process and specific considerations for specific abdominal organs is necessary to safely obtain adequate specimens. In this review, we discuss some points and techniques that need to be borne in mind to increase the chances of successful USPCB. We believe that the tips and considerations presented in this review will help radiologists perform USPCB to successfully retrieve target tissue from different organs with minimal complications

  13. Dysplastic naevi: to shave, or not to shave? A retrospective study of the use of the shave biopsy technique in the initial management of dysplastic naevi.

    Science.gov (United States)

    Armour, Katherine; Mann, Stephen; Lee, Stephen

    2005-05-01

    The management of dysplastic naevi is a controversial subject. This study sought to assess the usefulness of the shave biopsy technique in the initial management of dysplastic naevi, and to demonstrate the advantages over the punch biopsy technique. We report a retrospective observational study of histopathology specimens examined in one histopathology practice over a 14-month period. Patients who had a clinical diagnosis of 'dysplastic naevus', which had initially been biopsied using either a shave or punch biopsy, and then followed up with a full-thickness elliptical excision, were included in the study. Histopathological concordance between the shave and punch biopsy specimens and their respective follow-up elliptical excisions was compared. We found that 21 of 22 (95.5%) shave biopsies were concordant with their respective excision specimens, and that 29 of 41 (70.7%) punch biopsies were concordant with their respective elliptical excision specimens. Of the shave biopsy specimens reviewed, 66% showed that the dysplastic naevi were completely excised with the initial biopsy, compared with 21.2% of the punch biopsy specimens. These findings confirm that shave biopsies provide accurate diagnostic information in the assessment of dysplastic naevi. Shave biopsies enable the entire lesion to be submitted for histopathological assessment, improving the chances of an accurate diagnosis.

  14. Molecular Auditing: An Evaluation of Unsuspected Tissue Specimen Misidentification.

    Science.gov (United States)

    Demetrick, Douglas J

    2018-06-18

    Context Specimen misidentification is the most significant error in laboratory medicine, potentially accounting for hundreds of millions of dollars in extra health care expenses and significant morbidity in patient populations in the United States alone. New technology allows the unequivocal documentation of specimen misidentification or contamination; however, the value of this technology currently depends on suspicion of the specimen integrity by a pathologist or other health care worker. Objective To test the hypothesis that there is a detectable incidence of unsuspected tissue specimen misidentification among cases submitted for routine surgical pathology examination. Design To test this hypothesis, we selected specimen pairs that were obtained at different times and/or different hospitals from the same patient, and compared their genotypes using standardized microsatellite markers used commonly for forensic human DNA comparison in order to identify unsuspected mismatches between the specimen pairs as a trial of "molecular auditing." We preferentially selected gastrointestinal, prostate, and skin biopsies because we estimated that these types of specimens had the greatest potential for misidentification. Results Of 972 specimen pairs, 1 showed an unexpected discordant genotype profile, indicating that 1 of the 2 specimens was misidentified. To date, we are unable to identify the etiology of the discordance. Conclusions These results demonstrate that, indeed, there is a low level of unsuspected tissue specimen misidentification, even in an environment with careful adherence to stringent quality assurance practices. This study demonstrates that molecular auditing of random, routine biopsy specimens can identify occult misidentified specimens, and may function as a useful quality indicator.

  15. Analysis of prostate cancer localization toward improved diagnostic accuracy of transperineal prostate biopsy

    Directory of Open Access Journals (Sweden)

    Yoshiro Sakamoto

    2014-09-01

    Conclusions: The concordance of prostate cancer between prostatectomy specimens and biopsies is comparatively favorable. According to our study, the diagnostic accuracy of transperineal prostate biopsy can be improved in our institute by including the anterior portion of the Apex-Mid and Mid regions in the 12-core biopsy or 16-core biopsy, such that a 4-core biopsy of the anterior portion is included.

  16. Comparison of HER2 and phospho-HER2 expression between biopsy and resected breast cancer specimens using a quantitative assessment method.

    Directory of Open Access Journals (Sweden)

    Yalai Bai

    Full Text Available BACKGROUND: HER2/Neu (ErbB-2 overexpression, which occurs in 15-20% of breast cancer cases, is associated with better response to treatment with the drug trastuzumab. PhosphoHER2 (pHER2 has been evaluated for prediction of response to trastuzumab. Both markers are heterogeneously detected and are potentially subject to loss as a consequence of delayed time to fixation. Here, we quantitatively assess both markers in core needle biopsies (CNBs and matched tumor resections to assess concordance between the core and the resection and between HER2 and pHER2. METHODS: A selected retrospective collection of archival breast cancer cases yielded 67 cases with both core and resection specimens. Both HER2 and pTyr(1248HER2 were analyzed by the AQUA® method of quantitative immunofluorescence on each specimen pair. RESULTS: Both HER2 immunoreactivity (P<0.0001 and pTyr(1248HER2 immunoreactivity (P<0.0001 were lower in resections relative to CNB specimens. However, clinical implications of this change may not be evident since no case changed from 3+ (CNB to negative (resection. Assessment of pTyr(1248HER2 showed no direct correlation with HER2 in either CNB or resection specimens. CONCLUSIONS: The data suggest that measurement of both HER2 and phospho- Tyr(1248HER2, in formalin-fixed tissue by immunological methods is significantly affected by pre-analytic variables. The current study warrants the adequate handling of resected specimens for the reproducible evaluation of HER2 and pHER2. The level of pTyr(1248HER2, was not correlated to total HER2 protein. Further studies are required to determine the significance of these observations with respect to response to HER2 directed therapies.

  17. Usefulness of CT fluoroscopy-guided percutaneous needle biopsy in the presence of pneumothorax during biopsy

    International Nuclear Information System (INIS)

    O, Dong Hyun; Cho, Young Jun; Park, Yong Sung; Hwang, Cheol Mok; Kim, Keum Won; Kim, Ji Hyung

    2006-01-01

    When pneumothorax occurs during a percutaneous needle biopsy, the radiologist usually stops the biopsy. We evaluated the usefulness of computed tomographic (CT) fluoroscopy-guided percutaneous needle biopsy in the presence of pneumothorax during biopsy. We performed 288 CT fluoroscopy guided percutaneous needle biopsies to diagnose the pulmonary nodules. Twenty two of these patients had pneumothorax that occurred during the biopsy without obtaining an adequate specimen. After pneumothorax occurred, we performed immediate CT fluoroscopy guided percutaneous needle biopsies using an 18-gauge cutting needle. We evaluated the success rate of the biopsies and also whether or not the pneumothorax progressed. We classified these patients into two groups according to whether the pneumothorax progressed (Group 2) or not (Group 1) by measuring the longest distance between the parietal pleura and the visceral pleura both in the early and late pneumothorax. Additionally, we analyzed the relationship between the progression of pneumothorax after biopsy and 1) the depth of the pulmonary nodule; 2) the number of biopsies; 3) the presence or absence of emphysema at the biopsy site; and 4) the size of the pulmonary nodule. Biopsy was successful in 19 of 22 nodules (86.3%). Of the 19 nodules, 12 (63.2%) were malignant and 7 (36.8%) were benign. Twelve patients (54.5%) were classified as group 1 and 10 patients (45.4%) as group 2. The distance between the lung lesion and pleura showed a statistically significant difference between these two groups: ≤ 1 cm in distance for group 1 (81.8%) and group 2 (18.2%), and > 1 cm in distance for group 1 (30%) and group 2 (70%), ρ 0.05). When early pneumothorax occurs during a biopsy, CT fluoroscopy guided percutaneous needle biopsy is an effective and safe procedure. Aggravation of pneumothorax after biopsy is affected by the depth of the pulmonary nodule

  18. Percutaneous biopsy of malignant hepatic tumor in patients with bleeding tendency : usefulness of gelfoam plugging up the biopsy track

    International Nuclear Information System (INIS)

    Yoon, Hye Ran; Kwak, Byung Kook; Choi, Chi Hoon; Park, Yong Ok; Yang, Keun Myeong; Seo, Ja Young; Lee, Shin Hyung; Lee, Chang Joon; Shim, Hyung Jin

    1998-01-01

    To plug the biopsy site in eight patients with coagulopathy who had undergone percutaneous liver biopsy. To this end, gelfoam cartridge was used as a sealant. Materials and Methods: Using an 18G Tru-Cut-type disposable automated biopsy gun(Soo Ho Medi-tech, Seoul, Korea) and under US guidance, eight patients underwent percutaneous liver biopsy. After the gun had fired, the biopsy specimen in the inner stylet was retrieved while the outer cannula was held in place ; the cannula was then used to plug the biopsy tracks with gelfoam, using two or three cartridges. If bleeding occurred, this was controlled by the use of more gelfoam cartridges. Results:Diagnostic target tissue was obtained in seven of the eight patients(87.5%). Hepatocellular carcinoma was diagnosed in five cases and metastatic cancer in two. Profuse bleeding was observed in one patient(12.5%) and resolved by gelfoam plugging. Conclusion: We believe that in patients with coagulopathy who are required to undergo liver biopsy plugging the liver biopsy track with gelfoam cartridge is a simple, safe and useful method

  19. Differential contributions of specimen types, culturing, and 16S rRNA sequencing in diagnosis of prosthetic joint infections

    DEFF Research Database (Denmark)

    Larsen, Lone Heimann; Khalid, Vesal; Xu, Yijuan

    2018-01-01

    to variations in specimen sampling. In this prospective, multidisciplinary study of hip or knee prosthetic failures, we assessed the contributions of different specimen types, extended culture incubations, and 16S rRNA sequencing for diagnosing prosthetic joint infections (PJI). Project specimens included joint...... fluid (JF), bone biopsy specimens (BB), soft-tissue biopsy specimens (STB), and swabs (SW) from the prosthesis, collected in situ, and sonication fluid collected from prosthetic components (PC). Specimens were cultured for 6 (conventional) or 14 days, and 16S rRNA sequencing was performed at study...... completion. Of the 156 patients enrolled, 111 underwent 114 surgical revisions (cases) due to indications of either PJI (n = 43) or AF (n = 71). Conventional tissue biopsy cultures confirmed PJI in 28/43 (65%) cases and refuted AF in 3/71 (4%) cases; one case was not evaluable. Based on these results, minor...

  20. Confocal fluorescence microscopy for rapid evaluation of invasive tumor cellularity of inflammatory breast carcinoma core needle biopsies.

    Science.gov (United States)

    Dobbs, Jessica; Krishnamurthy, Savitri; Kyrish, Matthew; Benveniste, Ana Paula; Yang, Wei; Richards-Kortum, Rebecca

    2015-01-01

    Tissue sampling is a problematic issue for inflammatory breast carcinoma, and immediate evaluation following core needle biopsy is needed to evaluate specimen adequacy. We sought to determine if confocal fluorescence microscopy provides sufficient resolution to evaluate specimen adequacy by comparing invasive tumor cellularity estimated from standard histologic images to invasive tumor cellularity estimated from confocal images of breast core needle biopsy specimens. Grayscale confocal fluorescence images of breast core needle biopsy specimens were acquired following proflavine application. A breast-dedicated pathologist evaluated invasive tumor cellularity in histologic images with hematoxylin and eosin staining and in grayscale and false-colored confocal images of cores. Agreement between cellularity estimates was quantified using a kappa coefficient. 23 cores from 23 patients with suspected inflammatory breast carcinoma were imaged. Confocal images were acquired in an average of less than 2 min per core. Invasive tumor cellularity estimated from histologic and grayscale confocal images showed moderate agreement by kappa coefficient: κ = 0.48 ± 0.09 (p confocal images require less than 2 min for acquisition and allow for evaluation of invasive tumor cellularity in breast core needle biopsy specimens with moderate agreement to histologic images. We show that confocal fluorescence microscopy can be performed immediately following specimen acquisition and could indicate the need for additional biopsies at the initial visit.

  1. Biopsy techniques for intraocular tumors

    Directory of Open Access Journals (Sweden)

    Pukhraj Rishi

    2016-01-01

    Full Text Available Biopsy involves the surgical removal of a tissue specimen for histopathologic evaluation. Most intraocular tumors are reliably diagnosed based on the clinical evaluation or with noninvasive diagnostic techniques. However, accurately diagnosing a small percentage of tumors can be challenging. A tissue biopsy is thus needed to establish a definitive diagnosis and plan the requisite treatment. From fine-needle aspiration biopsy (FNAB to surgical excision, all tissue collection techniques have been studied in the literature. Each technique has its indications and limitations. FNAB has been reported to provide for 88-95% reliable and safe ophthalmic tumor diagnosis and has gained popularity for prognostic purposes and providing eye conserving treatment surgeries. The technique and instrumentation for biopsy vary depending upon the tissue involved (retina, choroid, subretinal space, vitreous, and aqueous, suspected diagnosis, size, location, associated retinal detachment, and clarity of the media. The cytopathologist confers a very important role in diagnosis and their assistance plays a key role in managing and planning the treatment for malignancies.

  2. Percutaneous biopsy of non-palpable breast lesions with the advanced breast biopsy instrumentation (ABBI): analysis of indication strategies; Perkutane stereotaktische Biopsie nicht palpabler Mammalaesionen mit dem Advanced Breast Biopsy Instrumentation (ABBI) System: kritische Evaluation der Indikationsstellung

    Energy Technology Data Exchange (ETDEWEB)

    Wedegaertner, U.; Otto, U.; Buitrago-Tellez, C.; Bremerich, J.; Bongartz, G. [Basel Univ. (Switzerland). Inst. fuer Diagnostische Radiologie; Oertli, D. [Basel Univ. (Switzerland). Inst. fuer Chirurgie; Torhorst, J. [Basel Univ. (Switzerland). Inst. fuer Pathologie

    2001-03-01

    Purpose: To compare the indications for biopsy with and without the use of the Breast Imaging Reporting and Data System. Material and methods: Biopsies using the ABBI were performed in 62 patients with 64 non-palpable evident mammographic lesions. The initial decision for biopsy was made by non-radiologists due to suspicious microcalcifications (n=53) and masses (n=11). The indication was retrospectively reassessed by adopting the BI-RADS classification by three radiologists in consensus. The positive predictive value (PPV) of both indication strategies was assessed and compared. Results: Biopsies adopting ABBI were performed without major side-effects and were diagnostic. Carcinoma was present in 14 lesions: nine specimens were diagnosed as DCIS and five as invasive carcinomas. For the 50 benign lesions histology revealed mastopathies (26/50) and fibroadenomas (8/50) as the most frequent diagnosis. The positive predictive value (PPV) for the initial indication was 22%, whereas PPV for BI-RADS based indications (categories 4 and 5) was 31%. Conclusion: ABBI enables stereotactically-guided procedures that result in representative and diagnostic biopsies. Standardized criteria like BI-RADS improve the PPV and should be a mandatory part of mammographic evaluation. Radiologists should remain involved in the decision making. (orig.) [German] Ziel: Perkutane stereotaktische Biopsien mit dem ABBI stellen eine neue Alternative in der Abklaerung nicht palpabler Mammalaesionen dar. Es soll die Indikationsstellung mit und ohne Anwendung des Breast Imaging Reporting and Data System (BI-RADS) analysiert werden. Material und Methoden: Insgesamt wurde bei 62 Patientinnen mit 64 Laesionen eine Biopsie mit dem ABBI System durchgefuehrt. Die primaere Indikation zur ABBI Biopsie wurde von Nicht-Radiologen aufgrund von Mikrokalzifikationen in 53 Faellen und einer unklaren Verdichtung in 11 Faellen gestellt. Zusaetzlich erfolgte eine retrospektive Indikationsstellung der biopsierten

  3. Diode laser for excisional biopsy of peripheral ossifying fibroma

    Directory of Open Access Journals (Sweden)

    Kirti Chawla

    2014-01-01

    Full Text Available Peripheral Ossifying Fibroma is one of the commonest occurring reactive lesions on gingiva. It is associated with local irritational factors and often interferes with speech, mastication and maintenance of oral hygiene, in addition to being aesthetically unpleasant. It is usually treated with surgical excision using scalpel and removal of irritational factors, often resulting in mucogingival defect. Other modalities such as radiosurgery and electrocautery have also been used for its management, but they cause changes in microarchitecture of biopsy specimen, altering the histologic picture for true diagnosis. We are presenting a case of excisional biopsy of this lesion in an adult female using a diode laser with excellent post-operative results, without affecting microarchitecture of biopsy specimen. The patient is being followed for last 1 year and no sign of recurrence has been found. A diode laser may offer a good alternative modality for management of such cases.

  4. Assessment of pain score and specimen adequacy for ultrasound-guided fine-needle aspiration biopsy of thyroid nodules

    Directory of Open Access Journals (Sweden)

    Liao LJ

    2017-12-01

    Full Text Available Li-Jen Liao,1 Wu-Chia Lo,1 Wan-Lun Hsu,2 Po-Wen Cheng,1 Cheng-Ping Wang3 1Department of Otolaryngology, Far Eastern Memorial Hospital, 2Genomics Research Center, Academia Sinica, 3Department of Otolaryngology, National Taiwan University Hospital, Taipei, Taiwan, Republic of China Objective: The aim of this study was to evaluate pain scores and specimen adequacy for ultrasound-guided fine-needle aspiration biopsy (US-FNAB of thyroid nodules without and with local anesthesia (LA. Materials and methods: The US-FNAB procedure was performed on 183 patients with and without LA. One puncture was made for solid nodules, and if patients could tolerate it, a two-puncture technique was used for nodules with a cystic change. Four-point verbal rating scores were assessed by a nursing assistant after completion of US-FNAB. To be an adequate specimen, at least six groups of follicular cells are required, and each group should contain at least 10 cells.Results: Immediately after US-FNAB, 92% of patients with LA and 80% without LA reported no or mild pain (p=0.01. Most patients tolerated the procedure well, with no pain (82.5% reported 5 minutes after the procedure. In univariate logistic regression, irregular boundary (odds ratio [OR]: 2.52, 95% confidence interval [CI]: 1.04–6.06, p=0.04, calcification (OR: 2.86, 95% CI: 1.06–7.76, p=0.04, and LA (OR: 0.35, 95% CI: 0.15–0.86, p=0.02 were significantly associated with immediate moderate or severe pain. Specimen adequacy was significantly associated with age (OR: 0.95, 95% CI: 0.92–0.97, p<0.01, heterogeneous echo-texture (OR: 1.76, 95% CI: 1.23–5.17, p=0.01, predominate solid architecture (OR: 2.78, 95% CI: 1.42–5.41, p<0.01, and the use of LA (OR: 3.34, 95% CI: 1.70–6.56, p<0.01. In multivariate logistic regression, patients receiving LA had lower risk of moderate or severe pain (OR: 0.25, 95% CI: 0.09–0.67, p=0.01 and higher chances of specimen adequacy (OR: 4.84, 95% CI: 2.17–10.7, p<0

  5. Real-time virtual sonography for navigation during targeted prostate biopsy using magnetic resonance imaging data

    International Nuclear Information System (INIS)

    Miyagawa, Tomoaki; Ishikawa, Satoru; Kimura, Tomokazu; Suetomi, Takahiro; Tsutsumi, Masakazu; Irie, Toshiyuki; Kondoh, Masanao; Mitake, Tsuyoshi

    2010-01-01

    The objective of this study was to evaluate the effectiveness of the medical navigation technique, namely, Real-time Virtual Sonography (RVS), for targeted prostate biopsy. Eighty-five patients with suspected prostate cancer lesions using magnetic resonance imaging (MRI) were included in this study. All selected patients had at least one negative result on the previous transrectal biopsies. The acquired MRI volume data were loaded onto a personal computer installed with RVS software, which registers the volumes between MRI and real-time ultrasound data for real-time display. The registered MRI images were displayed adjacent to the ultrasonographic sagittal image on the same computer monitor. The suspected lesions on T2-weighted images were marked with a red circle. At first suspected lesions were biopsied transperineally under real-time navigation with RVS and then followed by the conventional transrectal and transperineal biopsy under spinal anesthesia. The median age of the patients was 69 years (56-84 years), and the prostate-specific antigen level and prostate volume were 9.9 ng/mL (4.0-34.2) and 37.2 mL (18-141), respectively. Prostate cancer was detected in 52 patients (61%). The biopsy specimens obtained using RVS revealed 45/52 patients (87%) positive for prostate cancer. A total of 192 biopsy cores were obtained using RVS. Sixty-two of these (32%) were positive for prostate cancer, whereas conventional random biopsy revealed cancer only in 75/833 (9%) cores (P<0.01). Targeted prostate biopsy with RVS is very effective to diagnose lesions detected with MRI. This technique only requires additional computer and RVS software and thus is cost-effective. Therefore, RVS-guided prostate biopsy has great potential for better management of prostate cancer patients. (author)

  6. HISTOMORPHOLOGICAL PROFILE OF PROSTATE BIOPSIES AND CORRELATION WITH SERUM TPSA LEVEL

    Directory of Open Access Journals (Sweden)

    Laishram Deepak Kumar

    2017-11-01

    Full Text Available BACKGROUND In our study, 50 cases of transurethral prostate biopsies were evaluated histopathologically in the Department of Pathology in collaboration with Department of Urology, Regional Institute of Medical Sciences, Imphal, from October 2013 to September 2015. Total PSA (tPSA was estimated from serum samples in all cases. MATERIALS AND METHODS A total of 50 patients with elevated serum tPSA levels were inducted in this study and prostate needle biopsies taken. Matched prostatectomy specimens were also obtained for 7 cases. Specimens were kept in 10% formalin saline, grossing done and tissues processed. H and E stained sections were examined and the different histomorphological features noted. Gleason scoring system was used in cancers to stratify it. RESULTS Out of the 50 cases, 30 malignant (all adenocarcinomas, 4 premalignant and 16 benign cases were found. Gleason scoring on needle biopsies were compared against the prostatectomy specimens. In 5 carcinoma cases with Gleason score 3+3=6 on needle biopsy, 4 cases had similar findings in the corresponding prostatectomy specimens, however, it was upgraded in 1 case. Intermediate differentiation prostatic carcinomas with Gleason score 3+4=7 in needle biopsies were comparable with prostatectomy specimens in 2 cases. The differentiation of prostatic carcinoma vis-a-vis Gleason scoring correlated well with the PSA values. In carcinomas, tPSA value and the Gleason score had a very good correlation (rs = 0.908. Mean PSA value was found to increase from benign to premalignant and malignant cases, this was found to be statistically significant (p<0.05. CONCLUSION Use of newer technologies like MRI and serum PSA as a screening tool for prostate pathology have made it possible to identify prostate cancer at an earlier stage in younger age group and has an increased case detection rate. However, there is no marker to predict disease course and at times lead to overtreatment. Image-guided prostate biopsy

  7. MR-guided biopsies of lesions in the retroperitoneal space: technique and results

    International Nuclear Information System (INIS)

    Zangos, S.; Eichler, K.; Wetter, A.; Lehnert, T.; Hammerstingl, R.; Diebold, T.; Reichel, P.; Herzog, C.; Mack, M.G.; Vogl, T.J.; Hansmann, M.-L.

    2006-01-01

    The purpose of this study was to evaluate the safety and precision of MRI-guided biopsies of retroperitoneal space-occupying tumors in an open low-field system. In 30 patients with indistinct retroperitoneal tumors [paraaortic lesion (n=20), kidney (n=2), suprarenal gland (n=3) and pancreas (n=5)] MR-guided biopsies were performed using a low-field system (0.2 T, Magnetom Concerto, Siemens, Germany). For the monitoring of the biopsies T1-weighted FLASH sequences (TR/TE=160/5 ms; 90 ) were used in all patients and modified FLASH sequences (TR/TE=160/13 ms; 90 ) in ten patients. After positioning of the needle in the tumors 114 biopsy specimens were acquired in coaxial technique with 16-gauge cutting needles (Somatex, Germany). The biopsies were successfully performed in all patients without vascular or organ injuries. The visualization of the aortic blood flow with MRI facilitated the biopsy procedures of paraaortic lesions. The size of the lesions ranged from 1.6 to 7.5 cm. The median distance of the biopsy access path was 10.4 cm. Adequate specimens were obtained in 28 cases (93.3%) resulting in a correct histological classification of 27 lesions (90%). In conclusion, MR-guided biopsies of retroperitoneal lesions using an open low-field system can be performed safely and accurately and is an alternative to CT-guided biopsies. (orig.)

  8. Oral biopsy: Oral pathologist′s perspective

    Directory of Open Access Journals (Sweden)

    K L Kumaraswamy

    2012-01-01

    Full Text Available Many oral lesions may need to be diagnosed by removing a sample of tissue from the oral cavity. Biopsy is widely used in the medical field, but the practice is not quite widespread in dental practice. As oral pathologists, we have found many artifacts in the tissue specimen because of poor biopsy technique or handling, which has led to diagnostic pitfalls and misery to both the patient and the clinician. This article aims at alerting the clinicians about the clinical faults arising preoperatively, intraoperatively and postoperatively while dealing with oral biopsy that may affect the histological assessment of the tissue and, therefore, the diagnosis. It also reviews the different techniques, precautions and special considerations necessary for specific lesions.

  9. How to Interpret Thyroid Biopsy Results: A Three-Year Retrospective Interventional Radiology Experience

    International Nuclear Information System (INIS)

    Oppenheimer, Jason D.; Kasuganti, Deepa; Nayar, Ritu; Chrisman, Howard B.; Lewandowski, Robert J.; Nemcek, Albert A.; Ryu, Robert K.

    2010-01-01

    Results of thyroid biopsy determine whether thyroid nodule resection is appropriate and the extent of thyroid surgery. At our institution we use 20/22-gauge core biopsy (CBx) in conjunction with fine-needle aspiration (FNA) to decrease the number of passes and improve adequacy. Occasionally, both ultrasound (US)-guided FNA and CBx yield unsatisfactory specimens. To justify clinical recommendations for these unsatisfactory thyroid biopsies, we compare rates of malignancy at surgical resection for unsatisfactory biopsy results against definitive biopsy results. We retrospectively reviewed a database of 1979 patients who had a total of 2677 FNA and 663 CBx performed by experienced interventional radiologists under US guidance from 2003 to 2006 at a tertiary-care academic center. In 451 patients who had surgery following biopsy, Fisher's exact test was used to compare surgical malignancy rates between unsatisfactory and malignant biopsy cohorts as well as between unsatisfactory and benign biopsy cohorts. We defined statistical significance at P = 0.05. We reported an overall unsatisfactory thyroid biopsy rate of 3.7% (100/2677). A statistically significant higher rate of surgically proven malignancies was found in malignant biopsy patients compared to unsatisfactory biopsy patients (P = 0.0001). The incidence of surgically proven malignancy in unsatisfactory biopsy patients was not significantly different from that in benign biopsy patients (P = 0.8625). In conclusion, an extremely low incidence of malignancy was associated with both benign and unsatisfactory thyroid biopsy results. The difference in incidence between these two groups was not statistically significant. Therefore, patients with unsatisfactory biopsy specimens can be reassured and counseled accordingly.

  10. Use of diagnostic dynamic contrast-enhanced (DCE)-MRI for targeting of soft tissue tumour biopsies at 3T: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Noebauer-Huhmann, Iris-Melanie [Medical University of Vienna, Department of Biomedical Imaging and Image-guided Therapy, Division of Neuroradiology and Musculoskeletal Radiology, Vienna (Austria); Medical University of Vienna, High Field MR Center, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria); Medical University of Vienna/Vienna General Hospital, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria); Amann, Gabriele [Medical University of Vienna, Clinical Institute for Pathology, Vienna (Austria); Krssak, Martin [Medical University of Vienna, High Field MR Center, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria); Medical University of Vienna, Department of Internal Medicine III, Endocrinology and Metabolism, Vienna (Austria); Panotopoulos, Joannis; Funovics, Philipp; Windhager, Reinhard [Medical University of Vienna, Department of Orthopaedics, Vienna (Austria); Szomolanyi, Pavol [Medical University of Vienna, High Field MR Center, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria); Slovak Academy of Sciences, Department of Imaging Methods, Institute of Measurement Science, Bratislava (Slovakia); Weber, Michael; Czerny, Christian; Nemec, Stefan [Medical University of Vienna, Department of Biomedical Imaging and Image-guided Therapy, Division of Neuroradiology and Musculoskeletal Radiology, Vienna (Austria); Breitenseher, Martin [Landesklinikum Waldviertel Horn, Horn (Austria); Grabner, Guenther; Bogner, Wolfgang [Medical University of Vienna, High Field MR Center, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria); Dominkus, Martin [Orthopaedics Hospital Speising, Vienna (Austria); Trattnig, Siegfried [Medical University of Vienna, High Field MR Center, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria); Ludwig Boltzmann Institute for Experimental and Clinical Traumatology, Austrian Cluster for Tissue Regeneration, Vienna (Austria)

    2015-07-15

    To test the feasibility and accuracy of MR-guided soft tissue tumour biopsy at 3T, using the dynamic contrast-enhanced (DCE) information from staging MRI for intralesional targeting. After obtaining written informed consent for this institutional review board-approved study, 53 patients with suspected soft tissue tumours prospectively underwent preoperative staging MRI at 3T, including DCE, and subsequent MR-guided core needle biopsy. In 44/53 cases, DCE was heterogeneous and was used for intralesional biopsy targeting. Surgical, whole-specimen histology was used as the gold standard in 43/44 patients and revealed 42 soft tissue tumours (24 men; 18 women; mean age, 52 years; range, 19 - 84). Final surgical histology revealed eight benign lesions, six tumours of intermediate dignity, and 28 malignancies. All malignancies had shown heterogeneous DCE. The diagnostic yield of the biopsies was 100 % (42/42). Histological accuracy rates of biopsy were 100 % in predicting the dignity (42/42; 95 % CI [0.916 - 1.000]), 95.2 % for the tissue-specific entity (40/42; 95 % CI [0.847 - 0.987]), and 90.5 % for the tumour grade (38/42; 95 % CI [0.779 - 0.962]). Our preliminary study indicates that biopsy of soft tissue tumours can be performed accurately and safely with DCE targeted MR-guidance at 3T, using a combined staging/biopsy MRI protocol. (orig.)

  11. Use of diagnostic dynamic contrast-enhanced (DCE)-MRI for targeting of soft tissue tumour biopsies at 3T: preliminary results

    International Nuclear Information System (INIS)

    Noebauer-Huhmann, Iris-Melanie; Amann, Gabriele; Krssak, Martin; Panotopoulos, Joannis; Funovics, Philipp; Windhager, Reinhard; Szomolanyi, Pavol; Weber, Michael; Czerny, Christian; Nemec, Stefan; Breitenseher, Martin; Grabner, Guenther; Bogner, Wolfgang; Dominkus, Martin; Trattnig, Siegfried

    2015-01-01

    To test the feasibility and accuracy of MR-guided soft tissue tumour biopsy at 3T, using the dynamic contrast-enhanced (DCE) information from staging MRI for intralesional targeting. After obtaining written informed consent for this institutional review board-approved study, 53 patients with suspected soft tissue tumours prospectively underwent preoperative staging MRI at 3T, including DCE, and subsequent MR-guided core needle biopsy. In 44/53 cases, DCE was heterogeneous and was used for intralesional biopsy targeting. Surgical, whole-specimen histology was used as the gold standard in 43/44 patients and revealed 42 soft tissue tumours (24 men; 18 women; mean age, 52 years; range, 19 - 84). Final surgical histology revealed eight benign lesions, six tumours of intermediate dignity, and 28 malignancies. All malignancies had shown heterogeneous DCE. The diagnostic yield of the biopsies was 100 % (42/42). Histological accuracy rates of biopsy were 100 % in predicting the dignity (42/42; 95 % CI [0.916 - 1.000]), 95.2 % for the tissue-specific entity (40/42; 95 % CI [0.847 - 0.987]), and 90.5 % for the tumour grade (38/42; 95 % CI [0.779 - 0.962]). Our preliminary study indicates that biopsy of soft tissue tumours can be performed accurately and safely with DCE targeted MR-guidance at 3T, using a combined staging/biopsy MRI protocol. (orig.)

  12. Efficacy and Complications of Ultrasound-Guided Percutaneous Renal Biopsy Using Automatic Biopsy Gun in Pediatric Diffuse Renal Disease: Analysis of 97 Cases

    International Nuclear Information System (INIS)

    Han, Seung Min; Chung, Tae Woong; Yoon, Woong

    2007-01-01

    To evaluate the diagnostic efficacy and complications of ultrasound-guided percutaneous renal biopsy using automatic biopsy gun in patients with pediatric diffuse renal disease. Using an 18G automatic biopsy gun, biopsies were performed on 97 pediatric patients with clinically suspicious diffuse renal disease. The acquired tissue specimens were analyzed by photomicroscopy, immunofluorescence, and electron microscopy to support the diagnosis. In the 97 biopsies, the success of the histologic diagnosis, number of glomeruli, and complication rates were retrospectively evaluated by analyzing the variable exams and clinical records. Adequate tissue for histologic diagnosis was obtained in 91 of 97 biopsies (94%) and the mean number of glomeruli was 9.6. Complications such as minute pain, gross hematuria, and small perirenal hematoma presented in 22 of the 97 biopsies (23%), all of which either improved within 5-72 hours or did not need specific treatment. Ultrasound-guided percutaneous renal biopsy using 18G automatic biopsy gun is an effective and safe method for the histologic diagnosis of pediatric diffuse renal disease without any major complication

  13. [Lung Abscess Diagnosed as Adenocarcinoma by Needle Biopsy;Report of a Case].

    Science.gov (United States)

    Shomura, Shin; Suzuki, Hitoshi; Yada, Masaki; Kondo, Chiaki

    2015-07-01

    We report a case of lung abscess misdiagnosed as adenocarcinoma based on cytologic findings of the sample obtained from needle biopsy. A 45-year-old man consulted our hospital because of fever, wet cough and an abnormal shadow on a chest X-ray film. A chest computed tomography revealed gradually enlarging pulmonary mass in the left S6 infiltrating the S5. A diagnosis of lung cancer was suspected and surgery was performed. Pathological findings of the specimen showed atypical cells with a large nucleus and a gross papillary neoplasm by needle biopsy. The patient underwent left lower lobectomy and partial resection of upper lobe with standard nodal dissection. The final diagnosis was a lung abscess with pneumonia without evidence of malignancy. When an indeterminate pulmonary tumor must be diagnosed during an operation, we should perform partial resection if possible.

  14. Enzyme immunoassay of oestrogen receptors in needle biopsies from human liver

    DEFF Research Database (Denmark)

    Becker, U; Andersen, J; Poulsen, H S

    1991-01-01

    For quantitative assessments of sex hormone receptors in liver tissue, ligand binding assays are inconvenient, as they require large biopsies (0.5-1.0 g). The present study shows that it is possible to measure oestrogen receptors (ER) quantitatively in needle biopsy specimens as small as 10 mg...... by modifications of a commercial enzyme immunoassay employing monoclonal antibodies. Sucrose gradient centrifugation and the dextran charcoal method served as reference methods. A consecutive series of needle biopsies from patients suspected of liver disease were investigated. The biopsies (n = 37) had a median...

  15. Punch Biopsy Results in Misdiagnosis of Pilomatrixoma

    Directory of Open Access Journals (Sweden)

    Metin Temel

    2017-03-01

    Full Text Available Punch biopsy results in misdiagnosis of clinically unsuspected giant pilomatrixoma located over the parotid gland. This study presents a case of pilomatrixoma that was misdiagnosed as a malignant epithelial tumor using punch biopsy. A 25-year-old male was admitted to our clinic for the evaluation of a mass measuring 7×8×8 cm located over the parotid gland. The patient had previously undergone punch biopsy at another clinic because of a lesion in the parotid gland. Punch biopsy revealed a malignant epithelial tumor. The patient underwent excisional biopsy at our clinic. After the biopsy, the residual skin defect was treated using full-thickness skin grafts. The facial nerve and parotid gland were preserved during the biopsy. Histopathological examination of the excisional biopsy material revealed pilomatrixoma. Punch biopsy may result in misdiagnosis of skin lesions in the parotid gland. A differential diagnosis for benign tumors such as pilomatrixoma is essential prior to an aggressive surgical intervention of the parotid gland.

  16. Complete Spontaneous Regression of Merkel Cell Carcinoma After Biopsy: A Case Report and Review of the Literature.

    Science.gov (United States)

    Ahmadi Moghaddam, Parnian; Cornejo, Kristine M; Hutchinson, Lloyd; Tomaszewicz, Keith; Dresser, Karen; Deng, April; OʼDonnell, Patrick

    2016-11-01

    Merkel cell carcinoma (MCC) is a rare primary cutaneous neuroendocrine tumor that typically occurs on the head and neck of the elderly and follows an aggressive clinical course. Merkel cell polyomavirus (MCPyV) has been identified in up to 80% of cases and has been shown to participate in MCC tumorigenesis. Complete spontaneous regression of MCC has been rarely reported in the literature. We describe a case of a 79-year-old man that presented with a rapidly growing, 3-cm mass on the left jaw. An incisional biopsy revealed MCC. Additional health issues were discovered in the preoperative workup of this patient which delayed treatment. One month after the biopsy, the lesion showed clinical regression in the absence of treatment. Wide excision of the biopsy site with sentinel lymph node dissection revealed no evidence of MCC 2 months later. The tumor cells in the patient's biopsy specimen were negative for MCPyV by polymerase chain reaction and immunohistochemistry (CM2B4 antibody, Santa Cruz, CA). The exact mechanism for complete spontaneous regression in MCC is unknown. To our knowledge, only 2 previous studies evaluated the presence of MCPyV by polymerase chain reaction in MCC with spontaneous regression. Whether the presence or absence of MCPyV correlates with spontaneous regression warrants further investigation.

  17. Histological outcome of duodenal biopsies in patients with clinically suspected celiac disease - a study of 100 cases

    International Nuclear Information System (INIS)

    Sarfraz, T.; Khan, S.A.; Tariq, H.

    2018-01-01

    To see the histological outcome of duodenal biopsies done in patients clinically suspected of celiac disease. Study Design: Prospective descriptive study. Place and Duration of Study: Histopathology Department, Army Medical College Rawalpindi, from 1 Jan 2017 to 30 Jun 2017. Material and Methods: One hundred (100) cases were included in the study. Duodenal biopsies done in patients clinically suspected of celiac disease were included in the study. Inadequate biopsies were excluded from the study. All the normal and abnormal histological features were noted to make the diagnosis. Data was entered and analyzed by using SPSS version 17. Results: Duodenal biopsies of 100 patients, done in clinically suspected cases of celiac disease were analyzed histologically. Out of these 100 cases, 46 cases (46%) showed histological features consistent with celiac disease, while 38 cases (38%) revealed chronic non specific duodenitis, 2 cases (2%) were of giardiasis, while 14 biopsies (14%) were unremarkable with no significant pathology. Conclusion: A significant number of cases clinically suspected of celiac disease may not be showing histological features consistent with celiac disease on duodenal biopsies. Due to the changing presentation of disease, as well as the recognition of a number of potential clinical and histopathological mimics, communication between pathologists and gastroenterologists is essential for appropriate interpretation of duodenal biopsy specimens. (author)

  18. Paraffin-based immunohistochemistry in the evaluation of glomerular diseases in renal biopsies

    International Nuclear Information System (INIS)

    Rathore, M.U.; Khadim, M.T.; Atique, M.

    2012-01-01

    Objective: To determine sensitivity and specificity of paraffin-based immunohistochemistry in the evaluation of glomerular diseases in renal biopsies using immunofluorescence as gold standard. Study Design: Cross-sectional analytical study. Place and Duration of Study: Department of Histopathology, Armed Forces Institute of Pathology, Rawalpindi, from August 2008 to August 2009. Methodology: Seventy renal biopsy specimens fulfilling the inclusion criteria for light microscopy and immuno-fluorescence during the study period were evaluated. Antibodies to immunoglobulins (IgG, IgA, and IgM) and components of complement system (C3) were applied on 70 formalin-fixed paraffin-embedded renal biopsy specimens previously classified by means of light microscopy and immunofluorescence (IF). Staining for these antibodies was recorded as positive and negative for immunohistochemistry (IHC) and IF in paired proportions presuming IF as gold standard test. The sensitivity, specificity, positive predictive value and negative predictive value of individual antibody were calculated. Results: Of 70 patients, mean age was 33 +- 18 years ranging from 2 to 80 years. Forty five (64%) were males and 25 (36%) were females. The sensitivity, specificity and predictive values of individual antibodies to IgG, IgA, IgM and C3 were very low and generally in the range of 40 - 60%. Conclusion: The sensitivity, specificity and predictive values of immunohistochemistry on formalin-fixed paraffin-embedded renal biopsy specimens were very low and therefore, not suitable for evaluation of renal biopsies in current circumstances. (author)

  19. Histopathological analysis of gastric mucosal biopsies in non ulcer dyspepsia

    International Nuclear Information System (INIS)

    Sarfraz, T.; Hafeez, M.; Tariq, H.; Azhar, M.

    2016-01-01

    Objective: To find out the pattern of gastric mucosal histopathological findings in gastric biopsies of patients with non ulcer dyspepsia. Study Design: Prospective descriptive study. Place and Duration of Study: Histopathology department Combined Military Hospital (CMH) Kharian Pakistan from Jan to Dec 2015. Material and Methods: One hundred patients presenting at outpatient gastroenterology department with dyspepsia having no endoscopic lesion were included in the study. Two gastric mucosal biopsies from antrum and two from corpus were taken. The specimens were processed and examined histologically to see the changes. Results: Gastric biopsies of 100 patients including 65 males and 35 females presenting with non ulcer dyspepsia were studied. Most of the patients were between the age group of 31-50 years. Histological examination of gastric biopsies revealed 70 percent of patients having histological features of gastritis, while 30 percent having no significant histological finding. Chronic inflammation was seen in 70 cases (70 percent), activity in 15 cases (15 percent), glandular atrophy in 2 cases (2 percent) and intestinal metaplasia in 2 cases (2 percent). H.Pylori were identified in 25 cases (25 percent) based on haematoxylin and eosin (H and E) staining and modified giemsa staining. Conclusion: Most the cases of non ulcer dyspepsia show histological evidence of gastritis, however a significant number of patients showed no gastric mucosal histological abnormality. A significantly low frequency of H. Pylori in gastric biopsies noted in non ulcer dyspepsia cases may be due to more frequent use of antibiotics and acid suppressant drugs used by general practitioners at some stage of disease. (author)

  20. Use of percutaneous image-guided coaxial core-needle biopsy for diagnosis of intraabdominal lymphoma

    International Nuclear Information System (INIS)

    Shimizu, Ikuo; Okazaki, Yoichi; Takeda, Wataru; Kirihara, Takehiko; Sato, Keijiro; Fujikawa, Yuko; Ueki, Toshimitsu; Hiroshima, Yuki; Sumi, Masahiko; Ueno, Mayumi; Ichikawa, Naoaki; Kobayashi, Hikaru

    2014-01-01

    Although pathological diagnosis is essential for managing malignant lymphoma, intraabdominal lesions are generally difficult to approach due to the invasiveness of abdominal surgery. Here, we report the use of percutaneous image-guided coaxial core-needle biopsy (CNB) to obtain intraabdominal specimens for diagnosing intraabdominal lymphomas, which typically requires histopathological and immunohistochemical evaluation. We retrospectively reviewed consecutive cases involving computed tomography (CT)- or ultrasonography (US)-guided CNB to obtain pathological specimens for intraabdominal lesions from 1999 to 2011. Liver, spleen, kidney, and inguinal node biopsies were excluded. We compared CNBs with laparotomic biopsies. A total of 66 CNBs were performed for 59 patients (32 males, 27 females; median age, 63.5), including second or third repeat procedures. Overall diagnostic rate was 88.5%. None of the patients required additional surgical biopsies. Notably, the median interval between recognition of an intraabdominal mass and biopsy was only 1 day. Forty-five procedures were performed for hematological malignancies. Adequate specimens were obtained for histopathological diagnosis in 86% of cases. Flow cytometry detected lymphoma cells in 79.5% of cases. Twelve patients (nine males, three females; median age, 60) were eligible for surgical biopsy. While every postoperative course was satisfactory, median duration from lesion recognition to therapy initiation for lymphoma cases was significantly shorter for CNB than for surgical biopsy (14 vs. 35 days). While one-fourth of the patients were not eligible for the procedures, CNB is safe and highly effective for diagnosis of intraabdominal lymphomas. This method significantly improves sampling and potentially helps attain immunohistological distinction, allowing for more timely therapy initiation

  1. The diagnosis of cancer in thyroid fine needle aspiration biopsy. Surgery, repeat biopsy or specimen consultation?

    Directory of Open Access Journals (Sweden)

    Agata Stanek-Widera

    2016-05-01

    Full Text Available Fine needle aspiration biopsy (FNA is the only diagnostic method that allows a preoperative diagnosis of thyroid carcinoma. An unequivocal diagnosis of a malignant change is achievable only in cases in which all cytological criteria of carcinoma are met. The aim of the study was to evaluate the necessity of repeat thyroid FNA in patients with papillary thyroid carcinoma verified on consultative examination (CE. We analyzed cytology reports of thyroid FNA and CE that resulted in the diagnosis of papillary carcinoma. Evaluation of the correlation of the cytological diagnosis with the histopathology report was based on data obtained after the surgery. Between 2010 and 2015 in the Institute of Oncology (IO there were 184 cancers diagnosed on CE or in thyroid FNA performed primarily in IO. Additionally, 74 patients were subjected to repeat biopsy after confirmation of cancer in CE. Histopathological diagnosis of cancer was obtained in 62 (100% cases that were doubly confirmed with cytological examination. The remaining 12 patients were operated on outside the institute. From 110 FNA primarily performed in the IO, histopathological verification was achievable in 92 cases, from which 92 (100% provided a confirmation of cancer, and the remaining 18 patients were operated on outside the institute. High (100% specificity of cancer diagnosis in FNA established primarily and verified on CE (second independent assessment indicates that repeat FNA in order to confirm the diagnosis is unnecessary.

  2. Liver biopsy — the current view?

    African Journals Online (AJOL)

    needles, or the more recent cutting-core automated or semi-automated needles. These may be single units, or part of gun-type system with disposable needles. The pathologist's requirements of the specimen depend on whether diffuse disease or focal lesions are biopsied. The ideal tissue core for diffuse disease should be ...

  3. Proposal of an Appropriate Decalcification Method of Bone Marrow Biopsy Specimens in the Era of Expanding Genetic Molecular Study

    Directory of Open Access Journals (Sweden)

    Sung-Eun Choi

    2015-05-01

    Full Text Available Background: The conventional method for decalcification of bone specimens uses hydrochloric acid (HCl and is notorious for damaging cellular RNA, DNA, and proteins, thus complicating molecular and immunohistochemical analyses. A method that can effectively decalcify while preserving genetic material is necessary. Methods: Pairs of bilateral bone marrow biopsies sampled from 53 patients were decalcified according to protocols of two comparison groups: EDTA versus HCl and RDO GOLD (RDO versus HCl. Pairs of right and left bone marrow biopsy samples harvested from 28 cases were allocated into the EDTA versus HCl comparison group, and 25 cases to the RDO versus HCl comparison group. The decalcification protocols were compared with regards to histomorphology, immunohistochemistry, and molecular analysis. For molecular analysis, we randomly selected 5 cases from the EDTA versus HCl and RDO versus HCl groups. Results: The decalcification time for appropriate histomorphologic analysis was the longest in the EDTA method and the shortest in the RDO method. EDTA was superior to RDO or HCl in DNA yield and integrity, assessed via DNA extraction, polymerase chain reaction, and silver in situ hybridization using DNA probes. The EDTA method maintained intact nuclear protein staining on immunohistochemistry, while the HCl method produced poor quality images. Staining after the RDO method had equivocal results. RNA in situ hybridization using kappa and lambda RNA probes measured RNA integrity; the EDTA and RDO method had the best quality, followed by HCl. Conclusions: The EDTA protocol would be the best in preserving genetic material. RDO may be an acceptable alternative when rapid decalcification is necessary.

  4. Accuracy of post-radiotherapy biopsy before salvage radical prostatectomy.

    Science.gov (United States)

    Meeks, Joshua J; Walker, Marc; Bernstein, Melanie; Kent, Matthew; Eastham, James A

    2013-08-01

    To determine whether post-radiotherapy (RT) biopsy (PRB) adequately predicts the presence, location, and histological features of cancer in the salvage radical prostatectomy (SRP) specimen. Before salvage treatment, a PRB is required to confirm the presence of locally recurrent or persistent cancer and to determine the extent and location of the prostate cancer. SRP was performed between 1998 and 2011 on 198 patients. All patients underwent a PRB. PRB and SRP specimens were evaluated by a genitourinary pathologist. Patients had external-beam RT alone (EBRT; 71%) or brachytherapy with or without EBRT (29%). Of the men undergoing SRP, 26 (14%) were clinical stage ≥T3, with 13% of PRBs with Gleason score ≥8. Cancer was unilateral in 120 (61%) biopsies, with contralateral or bilateral prostate cancer at SRP in 49%. In the SRP specimen, cancer was multifocal in 57%. Cancer was upgraded at SRP in 58% of men, with 20% having an increase in primary Gleason grade. The accuracy of PRB varied by region from 62% to 76%, with undetected cancers ranging from 12% to 26% and most likely to occur at the mid-gland. Radiation-recurrent prostate cancers were often multifocal, and biopsy missed up to 20% of tumours. More than half of the cancers were upgraded at SRP, and many that were unilateral on PRB were bilateral at SRP. © 2013 BJU International.

  5. Changes in contact area characteristics of the ankle after a cartilage biopsy at the postero-medial rim of the talar dome.

    Science.gov (United States)

    Matricali, G A; Bartels, W; Labey, L; Dereymaeker, G Ph E; Luyten, F P; Vander Sloten, J

    2009-11-01

    Study the changes in local and generalized biomechanical characteristics of the ankle joint, associated with a well defined cartilage biopsy at the postero-medial rim of the talar dome, to evaluate its safety. Ten cadaver ankles were (sub-) physiologically loaded pre- and post-biopsy; in neutral position, 10 degrees of plantar-flexion (PF) and 10 degrees of dorsi-flexion (DF). Fuji film was used as transducer. Qualitatively, the coverage of the biopsy by the tibial plafond, and changes in the shape of the footprint were analyzed. Quantitatively, the pressure profile plot, normalized-tibio-talar contact area and the centroid position of pressure were examined. Results were reported as a mean for all specimens, and as individual values for every single specimen as well. Mean results did not show significant changes, but those of some single specimens did. The majority of those changes were in PF. Some occurred in N, and besides two exceptions none occurred in DF. Two specimens did not show any change. One specimen showed an isolated quantitative change. Seven specimens showed both qualitative and quantitative changes. However, all changes were of low-magnitude and contact stresses did not show any rebound effect. Although biopsies at the postero-medial rim of the talar dome did not induce on average significant changes in quantitative contact characteristics, few specimens did show some alterations. Currently, the investigated biopsy site seems safe, but long term follow-up studies in patients are needed for confirmation.

  6. Differential contributions of specimen types, culturing, and 16S rRNA sequencing in diagnosis of prosthetic joint infections

    DEFF Research Database (Denmark)

    Larsen, Lone Heimann; Khalid, Vesal; Xu, Yijuan

    2018-01-01

    Prosthetic joint failure is mainly caused by infection, aseptic failure (AF), and mechanical problems. Infection detection has been improved with modified culture methods and molecular diagnostics. However, comparisons between modified and conventional microbiology methods are difficult due...... to variations in specimen sampling. In this prospective, multidisciplinary study of hip or knee prosthetic failures, we assessed the contributions of different specimen types, extended culture incubations, and 16S rRNA sequencing for diagnosing prosthetic joint infections (PJI). Project specimens included joint...... fluid (JF), bone biopsy specimens (BB), soft-tissue biopsy specimens (STB), and swabs (SW) from the prosthesis, collected in situ, and sonication fluid collected from prosthetic components (PC). Specimens were cultured for 6 (conventional) or 14 days, and 16S rRNA sequencing was performed at study...

  7. Imprint cytology from ultrasound-guided core biopsies: accurate and immediate diagnosis in a one-stop breast clinic

    International Nuclear Information System (INIS)

    Jones, L.; Lott, M.F.; Calder, C.J.; Kutt, E.

    2004-01-01

    AIM: To investigate whether imprint cytology from ultrasound-guided core biopsy specimens was adequate for the National Health Service Breast Screening Programme (NHSBSP) guidelines. METHODS: We prospectively audited imprint cytology from ultrasound-guided core biopsy specimens. The performance indicators for imprint cytology specimens from 111 consecutive ultrasound-guided core biopsy were compared with standards set by the NHSBSP for fine-needle aspiration cytology (FNAC). RESULTS: Imprint cytology fulfilled the 'preferred' targets for absolute and complete sensitivity, specificity, positive predictive value, false-positive and false-negative rates, inadequate rate and inadequate rate from cancers. It also satisfied the minimum target for suspicious rate. The complete sensitivity was 97%, full specificity 78%, with 100% positive predictive value for C5 cytology and an inadequate rate from cancers of 1.5%. CONCLUSION: Imprint cytology from ultrasound-guided core biopsy allows same-day diagnosis and the collection of data regarding the grade of the carcinoma for treatment decisions from a single needle test

  8. Using the epigenetic field defect to detect prostate cancer in biopsy negative patients.

    Science.gov (United States)

    Truong, Matthew; Yang, Bing; Livermore, Andrew; Wagner, Jennifer; Weeratunga, Puspha; Huang, Wei; Dhir, Rajiv; Nelson, Joel; Lin, Daniel W; Jarrard, David F

    2013-06-01

    We determined whether a novel combination of field defect DNA methylation markers could predict the presence of prostate cancer using histologically normal transrectal ultrasound guided biopsy cores. Methylation was assessed using quantitative Pyrosequencing® in a training set consisting of 65 nontumor and tumor associated prostate tissues from University of Wisconsin. A multiplex model was generated using multivariate logistic regression and externally validated in blinded fashion in a set of 47 nontumor and tumor associated biopsy specimens from University of Washington. We observed robust methylation differences in all genes at all CpGs assayed (p prostate cancer (AUC 0.774, p = 0.001) and had a negative predictive value of 0.909. Comparison between 2 separate cores in patients in this validation set revealed similar methylation defects, indicating detection of a widespread field defect. A widespread epigenetic field defect can be used to detect prostate cancer in patients with histologically negative biopsies. To our knowledge this assay is unique, in that it detects alterations in nontumor cells. With further validation this marker combination (EVX1 and FGF1) has the potential to decrease the need for repeat prostate biopsies, a procedure associated with cost and complications. Copyright © 2013 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  9. The Orientation of Gastric Biopsy Samples Improves the Inter-observer Agreement of the OLGA Staging System.

    Science.gov (United States)

    Cotruta, Bogdan; Gheorghe, Cristian; Iacob, Razvan; Dumbrava, Mona; Radu, Cristina; Bancila, Ion; Becheanu, Gabriel

    2017-12-01

    Evaluation of severity and extension of gastric atrophy and intestinal metaplasia is recommended to identify subjects with a high risk for gastric cancer. The inter-observer agreement for the assessment of gastric atrophy is reported to be low. The aim of the study was to evaluate the inter-observer agreement for the assessment of severity and extension of gastric atrophy using oriented and unoriented gastric biopsy samples. Furthermore, the quality of biopsy specimens in oriented and unoriented samples was analyzed. A total of 35 subjects with dyspeptic symptoms addressed for gastrointestinal endoscopy that agreed to enter the study were prospectively enrolled. The OLGA/OLGIM gastric biopsies protocol was used. From each subject two sets of biopsies were obtained (four from the antrum, two oriented and two unoriented, two from the gastric incisure, one oriented and one unoriented, four from the gastric body, two oriented and two unoriented). The orientation of the biopsy samples was completed using nitrocellulose filters (Endokit®, BioOptica, Milan, Italy). The samples were blindly examined by two experienced pathologists. Inter-observer agreement was evaluated using kappa statistic for inter-rater agreement. The quality of histopathology specimens taking into account the identification of lamina propria was analyzed in oriented vs. unoriented samples. The samples with detectable lamina propria mucosae were defined as good quality specimens. Categorical data was analyzed using chi-square test and a two-sided p value <0.05 was considered statistically significant. A total of 350 biopsy samples were analyzed (175 oriented / 175 unoriented). The kappa index values for oriented/unoriented OLGA 0/I/II/III and IV stages have been 0.62/0.13, 0.70/0.20, 0.61/0.06, 0.62/0.46, and 0.77/0.50, respectively. For OLGIM 0/I/II/III stages the kappa index values for oriented/unoriented samples were 0.83/0.83, 0.88/0.89, 0.70/0.88 and 0.83/1, respectively. No case of OLGIM IV

  10. A Selective Biomarker Panel Increases the Reproducibility and the Accuracy in Endometrial Biopsy Diagnosis

    DEFF Research Database (Denmark)

    Nastic, Denis; Shanwell, Emma; Wallin, Keng-Ling

    2017-01-01

    Grading and histologic typing of endometrial cancer in biopsy material has a direct impact on the decision to perform lymphadenectomy and/or omentectomy in many cancer centers. Endometrial biopsies are among the most common general surgical pathology specimens. Multiple studies have shown...... that biopsy diagnosis suffers from a lack of reproducibility. Although many biomarkers have been proposed, none have been demonstrated to improve the diagnosis in the biopsy setting. In this study, 70 biopsies with endometrial carcinoma were supplemented with a biomarker panel consisting of ER, PR, P53...

  11. Analysis of 62 cases with stereotaxic breast biopsy with a prone table system: emphasis on lesions with microcalcificatios

    International Nuclear Information System (INIS)

    Chung, Il Gyu; Choe, Yeon Hyeon; Han, Boo Kyung; Byun, Hong Sik; Choo, In Wook

    1999-01-01

    To evaluate the efficacy of stereotaxic breast core biopsy using a prone table system, and the effects of operator experience, lesion characteristics and number of samples on biopsy results in cases involving nonpalpable breast lesions. We performed stereotaxic core biopsies of 62 nonpalpable mammographic lesions in 61 patients. Subsequent surgical excision was performed in 11 cases with microcalcifications and one case with a mass. We equally divided patients with microcalcifications into two groups (early and late periods) and analyzed the mammographic findings. Correlation of the pathologic results of core biopsy with those of surgical excision were investigated. In two patients, stereotaxic biopsy was impossible due to poor visibility of microcalcifications and thinness of the compressed breast. In 59 patients, core biopsy was successfully performed and specimens were adequate for pathologic examination. The average number of microcalcifications seen on specimen mammography in the two groups was 1.8(range : 0x8) and 2.5(range : 0x4) respectively. In patients from whom less than five and five or more samples were taken, the average number of microcalcifications seen on specimen mammography was 1.5(range : 0x6) and 2.6(range : 0x8), respectively, throughout the whole period. The pathologic findings were fibrocystic change in 50 cases, fibroadenoma in four, ductal carcinoma in situ in four, invasive ductal carcinoma in one, and atypical ductal hyperplasia in one. The agreement rate of pathologic results between core biopsy and surgical excision was 83%(10/12) for malignancy and 75% for histology. In three cases with disagreement between core and surgical pathologic results, the sampling number was small (3x 4 times) and in two of the three cases, microcalcifications were not visible on mammography operator experience and sampling numbers larger than five results in an increased number of microcalcifications in specimens and more reliable core biopsy

  12. Analysis of 62 cases with stereotaxic breast biopsy with a prone table system: emphasis on lesions with microcalcificatios

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Il Gyu; Choe, Yeon Hyeon; Han, Boo Kyung; Byun, Hong Sik; Choo, In Wook [Sungkyunkwan University College of Medicine, Seoul (Korea, Republic of)

    1999-02-01

    To evaluate the efficacy of stereotaxic breast core biopsy using a prone table system, and the effects of operator experience, lesion characteristics and number of samples on biopsy results in cases involving nonpalpable breast lesions. We performed stereotaxic core biopsies of 62 nonpalpable mammographic lesions in 61 patients. Subsequent surgical excision was performed in 11 cases with microcalcifications and one case with a mass. We equally divided patients with microcalcifications into two groups (early and late periods) and analyzed the mammographic findings. Correlation of the pathologic results of core biopsy with those of surgical excision were investigated. In two patients, stereotaxic biopsy was impossible due to poor visibility of microcalcifications and thinness of the compressed breast. In 59 patients, core biopsy was successfully performed and specimens were adequate for pathologic examination. The average number of microcalcifications seen on specimen mammography in the two groups was 1.8(range : 0x8) and 2.5(range : 0x4) respectively. In patients from whom less than five and five or more samples were taken, the average number of microcalcifications seen on specimen mammography was 1.5(range : 0x6) and 2.6(range : 0x8), respectively, throughout the whole period. The pathologic findings were fibrocystic change in 50 cases, fibroadenoma in four, ductal carcinoma in situ in four, invasive ductal carcinoma in one, and atypical ductal hyperplasia in one. The agreement rate of pathologic results between core biopsy and surgical excision was 83%(10/12) for malignancy and 75% for histology. In three cases with disagreement between core and surgical pathologic results, the sampling number was small (3x 4 times) and in two of the three cases, microcalcifications were not visible on mammography operator experience and sampling numbers larger than five results in an increased number of microcalcifications in specimens and more reliable core biopsy.

  13. Obstructive jaundice: a comparative study of forceps and brush biopsy under percutaneous transhepatic cholangiography

    International Nuclear Information System (INIS)

    Li Yongdong; Han Xinwei; Wu Gang; Ma Bo; Xing Gusheng

    2004-01-01

    Objective: To compare the sensitivity between forceps biopsy and brushing, and to explore a feasible approach to pathological diagnosis of the obstructive jaundice. Methods: 92 consecutive patients with obstructive jaundice underwent transluminal forceps biopsy and brushing during percutaneous transhepatic cholangiography and percutaneous transhepatic cholangiodrainage. The technique was performed through a preexisting percutaneous transhepatic tract with multiple specimens obtained after passing the forceps biopsy or brush into a 8-French sheath. Finally the specimens were fixed with formalin for pathologic or cytologic diagnosis. Results: The histopathologic diagnosis was acquired in 81 out of 92 patients with forceps biopsy reaching the successful rate of 97.83%. Sensitivity of forceps biopsy in 92 patients was higher than that of brush in 84 patients (88.04% vs 76.19% χ 2 =4.251, P= <0.05). Conclusions: Percutaneous transhepatic cholangiobiopsy is a simple technique with minimal invasion, high sensitivity and worthy to be used spread extensively. Percutaneous transluminal brush cytology is also an useful method for establishing a diagnosis of cholangiocarcinoma. (authors)

  14. Backscattering analysis of high frequency ultrasonic imaging for ultrasound-guided breast biopsy

    Science.gov (United States)

    Cummins, Thomas; Akiyama, Takahiro; Lee, Changyang; Martin, Sue E.; Shung, K. Kirk

    2017-03-01

    A new ultrasound-guided breast biopsy technique is proposed. The technique utilizes conventional ultrasound guidance coupled with a high frequency embedded ultrasound array located within the biopsy needle to improve the accuracy in breast cancer diagnosis.1 The array within the needle is intended to be used to detect micro- calcifications indicative of early breast cancers such as ductal carcinoma in situ (DCIS). Backscattering analysis has the potential to characterize tissues to improve localization of lesions. This paper describes initial results of the application of backscattering analysis of breast biopsy tissue specimens and shows the usefulness of high frequency ultrasound for the new biopsy related technique. Ultrasound echoes of ex-vivo breast biopsy tissue specimens were acquired by using a single-element transducer with a bandwidth from 41 MHz to 88 MHz utilizing a UBM methodology, and the backscattering coefficients were calculated. These values as well as B-mode image data were mapped in 2D and matched with each pathology image for the identification of tissue type for the comparison to the pathology images corresponding to each plane. Microcalcifications were significantly distinguished from normal tissue. Adenocarcinoma was also successfully differentiated from adipose tissue. These results indicate that backscattering analysis is able to quantitatively distinguish tissues into normal and abnormal, which should help radiologists locate abnormal areas during the proposed ultrasound-guided breast biopsy with high frequency ultrasound.

  15. Transjugular Renal Biopsy: Our Experience and Technical Considerations

    International Nuclear Information System (INIS)

    See, Teik Choon; Thompson, Barbara C.; Howie, Alexander J.; Karamshi, M.; Papadopoulou, Anthie M.; Davies, Neil; Tibballs, Jonathan

    2008-01-01

    The purpose of this study was to describe the indications for and technique of transjugular renal biopsy (TJRB) and evaluate the efficacy and complications of this method. We performed a retrospective review of 59 patients who underwent TJRB using the Quick-core needle biopsy system (Cook, Letchworth, UK) over a 4-year period. The indications for obtaining renal biopsy included acute renal failure, chronic renal failure, nephrotic syndrome, and proteinuria with or without other associated disease. Indications for the transjugular approach included coagulopathy, biopsy of a solitary kidney or essentially single functioning kidney, simultaneous renal and hepatic biopsy, morbid obesity, and failed percutaneous biopsy. All but four cases were performed via the right internal jugular vein. The right, left, or both renal veins were cannulated in 41, 14, and 4 cases, respectively. Combined liver and renal biopsies were obtained in seven cases. Diagnostic biopsy specimens were obtained in 56 of 59 patients (95%). The number and size of tissue cores ranged from 1 to 9 mm and from 1 to 20 mm, respectively. The mean numbers of glomeruli per procedure on light microscopy and electron microscopy were 10.3 and 2.6, respectively. Specimens for immunohistology were acquired in 49 cases, of which 40 were adequate. Of the 56 successful TJRB procedures, 34 (61%) were associated with isolated capsular perforation (19), contained subcapsular leak (10), isolated collecting system puncture (1), and concurrent collecting system and capsular perforation (4). There was a significant increase in capsular perforation with six or more needle passes, although no significant correlation was seen between number of needle passes and complication. Six patients had minor complications defined as hematuria or loin pain. Seven patients developed major complications, of whom five received blood transfusion alone. Two required intervention: in one an arteriocalyceal fistula was embolized and the patient

  16. Microbiology specimens obtained at the time of surgical lung biopsy for interstitial lung disease: clinical yield and cost analysis.

    Science.gov (United States)

    Fibla, Juan J; Brunelli, Alessandro; Allen, Mark S; Wigle, Dennis; Shen, Robert; Nichols, Francis; Deschamps, Claude; Cassivi, Stephen D

    2012-01-01

    In efforts to obtain complete results, current practice in surgical lung biopsy (LB) for interstitial lung disease (ILD) recommends sending lung tissue samples for bacterial, mycobacterial, fungal, and viral cultures. This study assesses the value of this practice by evaluating the microbiology findings obtained from LB for ILD and their associated costs. A total of 296 consecutive patients (140 women, 156 men, median age=61 years) underwent LB for ILD from 2002 to 2009. All had lung tissue sent for microbiology examination. Microbiology results and resultant changes in patient management were analyzed retrospectively. A cost analysis was performed based upon nominal hospital charges adjusted on current inflation rates. Cost data included cultures, stains, smears, direct fluorescent antibody studies, and microbiologist consulting fees. As many as 25 patients (8.4%) underwent open LB and 271 (91.6%) underwent thoracoscopic LB. A total of 592 specimens were assessed (range 1-4 per patient). The most common pathologic diagnoses were idiopathic pulmonary fibrosis in 122 (41.2%), cryptogenic organizing pneumonia in 31 (10.5%), and respiratory bronchiolitis ILD in 16 (5.4%). Microbiology testing was negative in 174 patients (58.8%). A total of 118 of 122 (96.7%) positive results were clinically considered to be contaminants and resulted in no change in clinical management. The most common contaminants were Propionibacterium acnes (38 patients; 31%) and Penicillium fungus (16 patients; 13%). In only four patients (1.4%), the organism cultured (Nocardia one, Histoplasma one, and Aspergillus fumigatus two) resulted in a change in clinical management. The cost of microbiology studies per specimen was $984 (€709), with a total cost for the study cohort being $582,000 (€420,000). The yield and impact on clinical management of microbiology specimens from LB for ILD is very low. Its routine use in LB is questionable. We suggest it should be limited to those cases of ILD with

  17. MRI-Guided Percutaneous Biopsy of Mediastinal Masses Using a Large Bore Magnet: Technical Feasibility

    Energy Technology Data Exchange (ETDEWEB)

    Garnon, J., E-mail: juliengarnon@gmail.com [Nouvel Hôpital Civil, Department of Interventional Radiology (France); Ramamurthy, N., E-mail: nitin-ramamurthy@hotmail.com [Norfolk and Norwich University Hospital, Department of Radiology (United Kingdom); Caudrelier J, J., E-mail: caudjean@yahoo.fr [Nouvel Hôpital Civil, Department of Interventional Radiology (France); Erceg, G., E-mail: erceggorislav@yahoo.com; Breton, E., E-mail: ebreton@unistra.fr [ICube, University of Strasbourg, CNRS (France); Tsoumakidou, G., E-mail: gtsoumakidou@yahoo.com; Rao, P., E-mail: pramodrao@me.com; Gangi, A., E-mail: gangi@unistra.fr [Nouvel Hôpital Civil, Department of Interventional Radiology (France)

    2016-05-15

    ObjectiveTo evaluate the diagnostic accuracy and safety of magnetic resonance imaging (MRI)-guided percutaneous biopsy of mediastinal masses performed using a wide-bore high-field scanner.Materials and MethodsThis is a retrospective study of 16 consecutive patients (8 male, 8 female; mean age 74 years) who underwent MRI-guided core needle biopsy of a mediastinal mass between February 2010 and January 2014. Size and location of lesion, approach taken, time for needle placement, overall duration of procedure, and post-procedural complications were evaluated. Technical success rates and correlation with surgical pathology (where available) were assessed.ResultsTarget lesions were located in the anterior (n = 13), middle (n = 2), and posterior mediastinum (n = 1), respectively. Mean size was 7.2 cm (range 3.6–11 cm). Average time for needle placement was 9.4 min (range 3–18 min); average duration of entire procedure was 42 min (range 27–62 min). 2–5 core samples were obtained from each lesion (mean 2.6). Technical success rate was 100 %, with specimens successfully obtained in all 16 patients. There were no immediate complications. Histopathology revealed malignancy in 12 cases (4 of which were surgically confirmed), benign lesions in 3 cases (1 of which was false negative following surgical resection), and one inconclusive specimen (treated as inaccurate since repeat CT-guided biopsy demonstrated thymic hyperplasia). Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy in our study were 92.3, 100, 100, 66.7, and 87.5 %, respectively.ConclusionMRI-guided mediastinal biopsy is a safe procedure with high diagnostic accuracy, which may offer a non-ionizing alternative to CT guidance.

  18. Incidence of cholesterol in periapical biopsies among adolescent and elderly patients.

    Science.gov (United States)

    Slutzky-Goldberg, Iris; Baev, Valery; Volkov, Alexander; Zini, Avi; Tsesis, Igor

    2013-12-01

    Cholesterol clefts are common histologic findings in periapical biopsies; they have a reported incidence in periapical periodontitis of up to 44%. Cholesterol crystals are also recognized in advanced atherosclerotic plaques in humans. Male sex, genetic abnormalities, and age have been associated with advanced atherosclerotic lesions. Among these nonmodifiable risk factors, age is the most dominant. The aim of the study was to evaluate if age is also linked to cholesterol deposition in periapical periodontitis. The database of biopsy reports obtained between 2006 and 2009 was searched for specimens diagnosed as radicular cysts or periapical granulomas. Only data relating to biopsies obtained from adolescent (13-21 years old) and elderly (over 60 years old) patients were selected. The biopsies were examined by a pathologist under a light microscope (Zeiss, Jena, Germany) at magnifications of 40×-200×. The available material was scanned for the presence of cholesterol clefts and foamy cells in radicular cysts and granulomas. A total of 41 specimens were collected in the adolescent group and 48 specimens in the elderly group over a 4-year period. A higher incidence of cholesterol was found in the elderly group compared with that in the adolescent group (odds ratio = 6.857). The highly significant incidence of cholesterol deposits in periapical biopsies among elderly patients may be a possible cause for the lack of repair. The mechanism for cholesterol accumulation is probably similar to the process leading to atherosclerosis and coronary artery disease. Statin administration may be advantageous for the treatment of persistent lesions. A clinician should be aware of the risk for persistent lesions after endodontic treatment in elderly patients. Copyright © 2013 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  19. Validation of morphometric analyses of small-intestinal biopsy readouts in celiac disease.

    Directory of Open Access Journals (Sweden)

    Juha Taavela

    Full Text Available BACKGROUND: Assessment of the gluten-induced small-intestinal mucosal injury remains the cornerstone of celiac disease diagnosis. Usually the injury is evaluated using grouped classifications (e.g. Marsh groups, but this is often too imprecise and ignores minor but significant changes in the mucosa. Consequently, there is a need for validated continuous variables in everyday practice and in academic and pharmacological research. METHODS: We studied the performance of our standard operating procedure (SOP on 93 selected biopsy specimens from adult celiac disease patients and non-celiac disease controls. The specimens, which comprised different grades of gluten-induced mucosal injury, were evaluated by morphometric measurements. Specimens with tangential cutting resulting from poorly oriented biopsies were included. Two accredited evaluators performed the measurements in blinded fashion. The intraobserver and interobserver variations for villus height and crypt depth ratio (VH:CrD and densities of intraepithelial lymphocytes (IELs were analyzed by the Bland-Altman method and intraclass correlation. RESULTS: Unevaluable biopsies according to our SOP were correctly identified. The intraobserver analysis of VH:CrD showed a mean difference of 0.087 with limits of agreement from -0.398 to 0.224; the standard deviation (SD was 0.159. The mean difference in interobserver analysis was 0.070, limits of agreement -0.516 to 0.375, and SD 0.227. The intraclass correlation coefficient in intraobserver variation was 0.983 and that in interobserver variation 0.978. CD3(+ IEL density countings in the paraffin-embedded and frozen biopsies showed SDs of 17.1% and 16.5%; the intraclass correlation coefficients were 0.961 and 0.956, respectively. CONCLUSIONS: Using our SOP, quantitative, reliable and reproducible morphometric results can be obtained on duodenal biopsy specimens with different grades of gluten-induced injury. Clinically significant changes were

  20. Posttreatment biopsy results following interstitial brachytherapy in early-stage prostate cancer

    International Nuclear Information System (INIS)

    Prestidge, Bradley R.; Hoak, David C.; Grimm, Peter D.; Ragde, Haakon; Cavanagh, William; Blasko, John C.

    1997-01-01

    Purpose: To assess pathologic control rates for prostatic carcinoma as determined by postimplant prostate biopsy in a large series of consecutive patients who have received permanent interstitial brachytherapy using a contemporary transrectal ultrasound-directed, transperineal, computer generated, volume technique. Methods and Materials: Four hundred and two patients received permanent 125 I or 103 Pd interstitial brachytherapy as primary treatment for early stage prostatic carcinoma at the Northwest Tumor Institute between January 1988 and January 1994. Of these, 201 have consented to biopsy 12 or more months postimplant with a median follow-up of 40 months (range: 12-83 months). None had received homonal manipulation. A total of 361 biopsies was performed on 201 patients with a range of one to six annual biopsies per patient (91 received multiple, serial biopsies). Of the 161 patients more than 12 months postimplant who have not been biopsied, most have been unwilling or unable to submit to biopsy. Only six patients with biochemical progression have not been biopsied. There was no difference in the presenting characteristics or implant parameters between those patients biopsied and those that were not. One hundred and forty-three received 125 I (71%) prescribed to a MPD of 160 Gy with a median activity of 35.5 mCi, and 58 (29%) received 103 Pd prescribed to a MPD of 115 Gy with a median activity of 123 mCi. Multiple biopsies were performed under transrectal ultrasound guidance, and all specimens were classified as either negative, indeterminate, or positive. Results: At the time of last biopsy, 161 (80%) have achieved negative pathology, 34 (17%) remain indeterminate, and 6 (3%) have been positive. Only 2 of the 186 patients with a PSA < 4.0 ng/ml at the time of biopsy were positive. Among those 33 indeterminate patients with a subsequent biopsy, 28 have converted to negative, 2 to positive, and 3 remain unchanged to date. Conclusions: These data demonstrate at

  1. Magnetic resonance elastography is as accurate as liver biopsy for liver fibrosis staging.

    Science.gov (United States)

    Morisaka, Hiroyuki; Motosugi, Utaroh; Ichikawa, Shintaro; Nakazawa, Tadao; Kondo, Tetsuo; Funayama, Satoshi; Matsuda, Masanori; Ichikawa, Tomoaki; Onishi, Hiroshi

    2018-05-01

    Liver MR elastography (MRE) is available for the noninvasive assessment of liver fibrosis; however, no previous studies have compared the diagnostic ability of MRE with that of liver biopsy. To compare the diagnostic accuracy of liver fibrosis staging between MRE-based methods and liver biopsy using the resected liver specimens as the reference standard. A retrospective study at a single institution. In all, 200 patients who underwent preoperative MRE and subsequent surgical liver resection were included in this study. Data from 80 patients were used to estimate cutoff and distributions of liver stiffness values measured by MRE for each liver fibrosis stage (F0-F4, METAVIR system). In the remaining 120 patients, liver biopsy specimens were obtained from the resected liver tissues using a standard biopsy needle. 2D liver MRE with gradient-echo based sequence on a 1.5 or 3T scanner was used. Two radiologists independently measured the liver stiffness value on MRE and two types of MRE-based methods (threshold and Bayesian prediction method) were applied. Two pathologists evaluated all biopsy samples independently to stage liver fibrosis. Surgically resected whole tissue specimens were used as the reference standard. The accuracy for liver fibrosis staging was compared between liver biopsy and MRE-based methods with a modified McNemar's test. Accurate fibrosis staging was achieved in 53.3% (64/120) and 59.1% (71/120) of patients using MRE with threshold and Bayesian methods, respectively, and in 51.6% (62/120) with liver biopsy. Accuracies of MRE-based methods for diagnoses of ≥F2 (90-91% [108-9/120]), ≥F3 (79-81% [95-97/120]), and F4 (82-85% [98-102/120]) were statistically equivalent to those of liver biopsy (≥F2, 79% [95/120], P ≤ 0.01; ≥F3, 88% [105/120], P ≤ 0.006; and F4, 82% [99/120], P ≤ 0.017). MRE can be an alternative to liver biopsy for fibrosis staging. 3. Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018;47:1268-1275. © 2017

  2. Small intestinal biopsies in celiac disease: duodenal or jejunal?

    NARCIS (Netherlands)

    Meijer, JW; Wahab, PJ; Mulder, C.J.J.

    2003-01-01

    BACKGROUND: For diagnosis and follow-up of celiac disease, pediatric societies advise that intestinal mucosal specimens should be obtained using suction capsule from the jejunum. This procedure is strenuous for patients, time-consuming, expensive and requires radiographic guidance. Mucosal biopsies

  3. Endometrial biopsy findings in postmenopausal bleeding

    International Nuclear Information System (INIS)

    Sarfraz, T.; Tariq, H.

    2007-01-01

    To study endometrial histopathology in women presenting with postmenopausal bleeding. A two-year study from January 2003 to December 2004 of 100 cases of postmenopausal bleeding was conducted at Combined Military Hospital, Sialkot. The histopathology of endometrial biopsy specimens was done to find out the causes of postmenopausal bleeding in these ladies. All these 100 patients had confirmed menopause and the average age was 55 years and above. The most common histopathological diagnosis was senile endometrial atrophy (27%), followed by simple cystic hyperplasia in (17%). Three cases of simple cystic hyperplasia had coexistent ovarian tumors. Glandular hyperplasia without atypia was seen in 6% and with atypia in 4%. Other causes were endometritis (13%), endometrial polyps (8%), proliferative phase endometrium (6%) and secretary phase endometrium (5%). Endometrial carcinoma was seen in (6%) cases, (8%) biopsy specimens were non-representative. Although senile endometrial atrophy was most commonly found in these ladies but a significant percentage of endometrial hyperplasia and endometrial cancer implies the need for investigating all cases of postmenopausal bleeding. Bimanual examination and pelvic ultrasonography should be combined with endometrial sampling so that rare pelvic pathologies may not be missed. (author)

  4. Utility of abdominal skin plus subcutaneous fat and rectal mucosal biopsy in the diagnosis of AL amyloidosis with renal involvement.

    Directory of Open Access Journals (Sweden)

    Ting Li

    Full Text Available Skin fat biopsy of the abdominal wall is a simple and safe method for detecting amyloidosis, and rectal mucosal biopsy is also frequently used for screening for the disease; however, the sensitivity of these approaches has not been fully studied. The aim of this study was to evaluate the efficacy of skin fat biopsy combined with rectal mucosal biopsy as a screening procedure for the diagnosis of systemic immunoglobulin light-chain (AL amyloidosis.We retrospectively analyzed 224 AL amyloidosis patients confirmed by renal biopsy, including a test group of 165 patients and validation group of 59 patients. Surgical skin fat biopsy from the abdominal wall and rectal mucosal biopsy under endoscopy was performed to obtain specimens. Congo red staining and immunofluorescence staining with antibodies against light chains were performed to type the disease. Pathology reports were reviewed to assess the diagnostic sensitivity of skin fat biopsy and rectal mucosal biopsy. Diagnostic specificity was not examined in the present study, because no healthy volunteers and only few patients with other diseases had performed immunofluorescence staining on skin fat and rectal specimens.Of the 165 patients in the test group, Congo red staining of skin fat and rectal mucosal specimens was associated with a sensitivity of 89.3% and 94.8%, respectively. The sensitivity increased to 98.9% by combining both biopsy methods. Immunofluorescence stains were positive in 81.1% of patients undergoing skin fat biopsy and 84.7% of patients undergoing rectal mucosal biopsy. Immunofluorescence stains yielded positive results in 86.7% of cases combining skin fat biopsy with rectal mucosal biopsy. The diagnostic results also performed well in the validation group.Surgical skin biopsy including the subcutaneous fat pad can be performed safely at the bedside and is useful for diagnosing AL amyloidosis. Combining skin fat biopsy with rectal mucosal biopsy may identify amyloid deposits in

  5. Quantification of tumor extension in prostate biopsies: importance in the identification of confined tumors

    Directory of Open Access Journals (Sweden)

    Leite Kátia R.M.

    2003-01-01

    Full Text Available OBJECTIVE: To assess the importance of quantifying the adenocarcinoma in prostate biopsies when determining the tumor's final stage in patients who undergo radical prostatectomy. To identify the best methodology for obtaining such data. PATIENTS AND METHODS: Prostate biopsies from 132 patients were examined, with determination of Gleason histological grade and tumor volume in number of involved fragments, tumor extent of the fragment mostly affected by the tumor and the total percentage of tumor in the specimen. Theses parameters were statistically correlated with the neoplasia's final stage following the evaluation of radical prostatectomy specimens. RESULTS: An average of 12 and a median of 14 biopsy fragments were evaluated per patient. In the univariate analysis the Gleason histological grade, the largest tumor extent in one fragment and the total percentage of tumor in the specimen were correlated with tumor stage of the surgical specimen. In the multivariate analysis, the Gleason histological grade and the total percentage of tumor were strongly correlated with the neoplasia's final stage. The risk of the tumor not being confined was 3 for Gleason 7 tumors and 10.6 for Gleason 8 tumors or above. In cases where the tumor involved more than 60% of the specimen, the risk of non-confined disease was 4.4 times. Among 19 patients with unfavorable histological parameters, Gleason > 7 and extension greater than 60% the tumor final stage was pT3 in 95%. CONCLUSION: When associated to the Gleason histological grade, tumor quantification in prostate biopsies is an important factor for determining organ-confined disease, and among the methods, total percentage of tumor is the most informative one. Such data should be included in the pathological report and must be incorporated in future nomograms.

  6. Plugged percutaneous biopsy of the liver in living-donor liver transplantation recipients suspected to have graft rejection.

    Science.gov (United States)

    Kim, Sung Jung; Won, Je Hwan; Kim, Young Bae; Wang, Hee-Jung; Kim, Bong-Wan; Kim, Haeryoung; Kim, Jinoo

    2017-07-01

    Background Percutaneous biopsy is a widely-accepted technique for acquiring histologic samples of the liver. When there is concern for bleeding, plugged percutaneous biopsy (PPB) may be performed, which involves embolization of the biopsy tract. Purpose To evaluate the efficacy and safety of PPB of the liver in patients suspected to have graft rejection after living-donor liver transplantation (LDLT). Material and Methods During January 2007 and December 2013, 51 patients who underwent PPB of the liver under the suspicion of post-LDLT graft rejection were retrospectively analyzed. A total of 73 biopsies were performed. Biopsy was performed with a 17-gauge core needle and 18-gauge cutting needle. The needle tract was embolized using gelatin sponge (n = 44) or N-butyl cyanoacrylate (NBCA) (n = 29). The specimens were reviewed to determine their adequacy for histologic diagnosis. We reviewed all medical records after PPB. Results Specimens were successfully acquired in all procedures (100%). They were adequate for diagnosis in 70 cases (95.9%) and inadequate in three (1.3%). Average of 9.8 complete portal tracts was counted per specimen. One minor complication (1.4%) occurred where the patient had transient fever after the procedure. Conclusion PPB is easy and safe to perform in LDLT recipients and provides high diagnostic yield.

  7. Accuracy of HER2 status determination on breast core-needle biopsies (immunohistochemistry, FISH, CISH and SISH vs FISH).

    Science.gov (United States)

    Arnould, Laurent; Roger, Pascal; Macgrogan, Gaëtan; Chenard, Marie-Pierre; Balaton, André; Beauclair, Sophie; Penault-Llorca, Frederique

    2012-05-01

    Preoperative breast cancer diagnosis on core biopsies has become a standard of care in many countries. Controversies exist concerning the accuracy of HER2 testing on biopsies as compared with surgical specimens, and few data exist concerning the use of emerging technologies such as bright-field in-situ hybridization in such a setting. A French multicenter, cross-sectional, histopathological study assessed the concordance of HER2 status determined by immunohistochemistry and silver (SISH) or chromogenic in-situ hybridization (CISH) on core-needle biopsies with HER2 status determined by fluorescence in-situ hybridization (FISH) on surgical specimens. The concordance between biopsy and operative results was also assessed for each method. We studied 260 breast tumors from 24 centers between April 2003 and August 2009. Excellent concordance (κ: 0.92-0.97) was shown between immunohistochemistry and FISH with low discordance rates (2-4%), high specificity (97-98%) and sensitivity values (95-99%), with no significant difference according to the immunohistochemistry interpretation guidelines used. The correlation between SISH and CISH on biopsies and FISH on surgical samples was strong (κ: 0.96 and 0.94, respectively), with no significant difference between false negative rates or sensitivity and specificity values (2 and 5%, 99 and 96%, 98 and 98%, respectively). Whatever the evaluation technique, excellent concordance between biopsies and surgical specimens was observed (κ ≥ 0.97; discordance rates between 1 and 2%), with high sensitivity (98-99%) and specificity (98-100%). Based on these results, when FISH cannot be used, SISH and/or CISH could be proposed as an alternative method to determine HER2 status and to confirm any ambiguous immunohistochemistry results, either for preoperative percutaneous biopsies or for surgical specimens. They could also be used for quality controls and immunohistochemistry calibration.

  8. Diagnostic value of polymerase chain reaction analysis of skin biopsies in purpura fulminans.

    Science.gov (United States)

    Beau, Caroline; Vlassova, Natalia; Sarlangue, Jean; Brissaud, Olivier; Léauté-Labrèze, Christine; Boralevi, Franck

    2013-01-01

    Even though prompt diagnosis and treatment of purpura fulminans (PF) is essential to reduce mortality, early administration of antibiotics may preclude identification of the causative agent by standard bacterial cultures and thus render definitive diagnosis impossible. Here we present a case of an infant with PF and negative bacterial cultures for whom polymerase chain reaction (PCR) analysis of a cutaneous biopsy specimen obtained 4 days after initiation of antibiotics identified the genomic sequence of Neisseria meningitidis genogroup C. When bacterial cultures fail to provide useful information, PCR of skin biopsy specimens can be a valuable diagnostic tool in PF. © 2013 Wiley Periodicals, Inc.

  9. Cryobiopsy: Should This Be Used in Place of Endobronchial Forceps Biopsies?

    Directory of Open Access Journals (Sweden)

    Edmundo R. Rubio

    2013-01-01

    Full Text Available Forceps biopsies of airway lesions have variable yields. The yield increases when combining techniques in order to collect more material. With the use of cryotherapy probes (cryobiopsy larger specimens can be obtained, resulting in an increase in the diagnostic yield. However, the utility and safety of cryobiopsy with all types of lesions, including flat mucosal lesions, is not established. Aims. Demonstrate the utility/safety of cryobiopsy versus forceps biopsy to sample exophytic and flat airway lesions. Settings and Design. Teaching hospital-based retrospective analysis. Methods. Retrospective analysis of patients undergoing cryobiopsies (singly or combined with forceps biopsies from August 2008 through August 2010. Statistical Analysis. Wilcoxon signed-rank test. Results. The comparative analysis of 22 patients with cryobiopsy and forceps biopsy of the same lesion showed the mean volumes of material obtained with cryobiopsy were significantly larger (0.696 cm3 versus 0.0373 cm3, P=0.0014. Of 31 cryobiopsies performed, one had minor bleeding. Cryopbiopsy allowed sampling of exophytic and flat lesions that were located centrally or distally. Cryobiopsies were shown to be safe, free of artifact, and provided a diagnostic yield of 96.77%. Conclusions. Cryobiopsy allows safe sampling of exophytic and flat airway lesions, with larger specimens, excellent tissue preservation and high diagnostic accuracy.

  10. Percutaneous CT-guided biopsy for lung lesions 1 cm or smaller: the technique, results and complication

    International Nuclear Information System (INIS)

    Song, Chi Sung

    2006-01-01

    The author wanted to assess the diagnostic accuracy and safety of percutaneous biopsy for lung lesions 1 cm or smaller; the biopsies were performed on the basis of the modified coaxial technique under CT guidance. Thirty-five patients (22 men and 13 women) 23-76 years old (average age: 56.8 years) with lung lesions 1 cm or smaller underwent CT-guided percutaneous biopsy. Fifteen patients had underlying primary malignancies. After an 18 G guiding cannula was introduced to the border of the small lung lesion via the modified coaxial technique, fine-needle aspiration biopsy with 21 G needle and core tissue biopsies with 19.5 G or 20 G biopsy guns were performed through the lumen of the guiding cannula. The core tissue biopsies were finished after 6 macroscopic core tissue specimens were obtained. When the needle hit the eccentric portion of the small lung lesion, a 'fanning-out' technique with using the guiding cannula was applied to get multiple core tissue specimens from the small lung lesion. The diagnostic accuracy of this method was evaluated and the complications were reviewed. Both the cytopathologic and histopathologic specimens were obtained in all 35 cases. The fanning-out technique was necessary in 15 cases (43%) for obtaining six core tissue specimens from small lesions. The final diagnoses were 17 malignant lesions and 18 benign lesions. Sixteen lesions were true-positive, eighteen were true-negative, none was false-positive and one was false-negative. The overall diagnostic accuracy was 97%. The sensitivity for detecting malignancy and the specificity for benign lesion were 94% and 100%, respectively. The positive and negative predictive values were 100% and 95%, respectively. The diagnostic ability to characterize the specific cell type of the malignant lesion was 94% (16 of 17), that for the benign lesions was 83% (15 of 18), and overall diagnostic ability was 89% (31 of 35). Five patients (14%) developed a pneumopthorax, and one of them (3%) received

  11. Cytologic anaplasia is a prognostic factor in osteosarcoma biopsies, but mitotic rate or extent of spontaneous tumor necrosis are not: a critique of the College of American Pathologists Bone Biopsy template.

    Science.gov (United States)

    Cates, Justin Mm; Dupont, William D

    2017-01-01

    The current College of American Pathologists cancer template for reporting biopsies of bone tumors recommends including information that is of unproven prognostic significance for osteosarcoma, such as the presence of spontaneous tumor necrosis and mitotic rate. Conversely, the degree of cytologic anaplasia (degree of differentiation) is not reported in this template. This retrospective cohort study of 125 patients with high-grade osteosarcoma was performed to evaluate the prognostic impact of these factors in diagnostic biopsy specimens in predicting the clinical outcome and response to neoadjuvant chemotherapy. Multivariate Cox regression was performed to adjust survival analyses for well-established prognostic factors. Multivariate logistic regression was used to determine odds ratios for good chemotherapy response (≥90% tumor necrosis). Osteosarcomas with severe anaplasia were independently associated with increased overall and disease-free survival, but mitotic rate and spontaneous necrosis had no prognostic impact after controlling for other confounding factors. Mitotic rate showed a trend towards increased odds of a good histologic response, but this effect was diminished after controlling for other predictive factors. Neither spontaneous necrosis nor the degree of cytologic anaplasia observed in biopsy specimens was predictive of a good response to chemotherapy. Mitotic rate and spontaneous tumor necrosis observed in pretreatment biopsy specimens of high-grade osteosarcoma are not strong independent prognostic factors for clinical outcome or predictors of response to neoadjuvant chemotherapy. Therefore, reporting these parameters for osteosarcoma, as recommended in the College of American Pathologists Bone Biopsy template, does not appear to have clinical utility. In contrast, histologic grading schemes for osteosarcoma based on the degree of cytologic anaplasia may have independent prognostic value and should continue to be evaluated.

  12. Phosphotyrosine-based-phosphoproteomics scaled-down to biopsy level for analysis of individual tumor biology and treatment selection.

    Science.gov (United States)

    Labots, Mariette; van der Mijn, Johannes C; Beekhof, Robin; Piersma, Sander R; de Goeij-de Haas, Richard R; Pham, Thang V; Knol, Jaco C; Dekker, Henk; van Grieken, Nicole C T; Verheul, Henk M W; Jiménez, Connie R

    2017-06-06

    Mass spectrometry-based phosphoproteomics of cancer cell and tissue lysates provides insight in aberrantly activated signaling pathways and potential drug targets. For improved understanding of individual patient's tumor biology and to allow selection of tyrosine kinase inhibitors in individual patients, phosphoproteomics of small clinical samples should be feasible and reproducible. We aimed to scale down a pTyr-phosphopeptide enrichment protocol to biopsy-level protein input and assess reproducibility and applicability to tumor needle biopsies. To this end, phosphopeptide immunoprecipitation using anti-phosphotyrosine beads was performed using 10, 5 and 1mg protein input from lysates of colorectal cancer (CRC) cell line HCT116. Multiple needle biopsies from 7 human CRC resection specimens were analyzed at the 1mg-level. The total number of phosphopeptides captured and detected by LC-MS/MS ranged from 681 at 10mg input to 471 at 1mg HCT116 protein. ID-reproducibility ranged from 60.5% at 10mg to 43.9% at 1mg. Per 1mg-level biopsy sample, >200 phosphopeptides were identified with 57% ID-reproducibility between paired tumor biopsies. Unsupervised analysis clustered biopsies from individual patients together and revealed known and potential therapeutic targets. This study demonstrates the feasibility of label-free pTyr-phosphoproteomics at the tumor biopsy level based on reproducible analyses using 1mg of protein input. The considerable number of identified phosphopeptides at this level is attributed to an effective down-scaled immuno-affinity protocol as well as to the application of ID propagation in the data processing and analysis steps. Unsupervised cluster analysis reveals patient-specific profiles. Together, these findings pave the way for clinical trials in which pTyr-phosphoproteomics will be performed on pre- and on-treatment biopsies. Such studies will improve our understanding of individual tumor biology and may enable future p

  13. Sentinel lymph node biopsy in patients with a needle core biopsy diagnosis of ductal carcinoma in situ: is it justified?

    LENUS (Irish Health Repository)

    Doyle, B

    2012-02-01

    BACKGROUND: The incidence of ductal carcinoma in situ (DCIS) has increased markedly with the introduction of population-based mammographic screening. DCIS is usually diagnosed non-operatively. Although sentinel lymph node biopsy (SNB) has become the standard of care for patients with invasive breast carcinoma, its use in patients with DCIS is controversial. AIM: To examine the justification for offering SNB at the time of primary surgery to patients with a needle core biopsy (NCB) diagnosis of DCIS. METHODS: A retrospective analysis was performed of 145 patients with an NCB diagnosis of DCIS who had SNB performed at the time of primary surgery. The study focused on rates of SNB positivity and underestimation of invasive carcinoma by NCB, and sought to identify factors that might predict the presence of invasive carcinoma in the excision specimen. RESULTS: 7\\/145 patients (4.8%) had a positive sentinel lymph node, four macrometastases and three micrometastases. 6\\/7 patients had invasive carcinoma in the final excision specimen. 55\\/145 patients (37.9%) with an NCB diagnosis of DCIS had invasive carcinoma in the excision specimen. The median invasive tumour size was 6 mm. A radiological mass and areas of invasion <1 mm, amounting to "at least microinvasion" on NCB were predictive of invasive carcinoma in the excision specimen. CONCLUSIONS: SNB positivity in pure DCIS is rare. In view of the high rate of underestimation of invasive carcinoma in patients with an NCB diagnosis of DCIS in this study, SNB appears justified in this group of patients.

  14. No need for biopsies

    DEFF Research Database (Denmark)

    Gjødsbøl, Kristine; Skindersoe, Mette E; Christensen, Jens Jørgen

    2011-01-01

    collected. After 4 weeks, additional biopsy and filter paper pad samples were collected. Bacteria were isolated and identified at species level by standard methods. The most common bacterial species detected was Staphylococcus aureus found in 89% of the ulcers. No methicillin-resistant S. aureus isolates...... were found. We did not find any significant differences regarding the bacterial species isolated between the three sampling techniques. However, using multiple techniques led to identification of more species. Our study suggests that it is sufficient to use swab specimens to identify the bacterial...

  15. Ultrasound-guided percutaneous core needle biopsy of splenic lesions

    Energy Technology Data Exchange (ETDEWEB)

    Park, SangIk; Shin, Yong Moon; Won, Hyung Jin; Kim, Pyo Nyun; Lee, Moon Gyu [Dept. of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of)

    2017-05-15

    To evaluate the safety and efficacy of ultrasound-guided percutaneous core needle biopsy of splenic lesions. This retrospective study included 30 patients who underwent percutaneous core needle biopsy of their splenic lesions using 18- or 20-gauge needles between January 2001 and July 2016 in a single tertiary care center. The characteristics of the splenic lesions were determined by reviewing the ultrasound and computed tomography examinations. Acquisition rate and diagnostic accuracy were calculated, using pathologic results of the splenectomy specimen, clinical course and/or imaging follow-up as a reference standard. Post-procedure complications were identified from electronic medical records, laboratory findings and computed tomography images. Seventy-three specimens were obtained from the 30 patients and splenectomy was performed in 2 patients. Twenty-nine of the 30 patients had focal splenic lesions, while the remaining patient had homogeneous splenomegaly. Acquisition rate and diagnostic accuracy were 80.0% (24/30) and 76.7% (23/30), respectively. Perisplenic hemorrhage without hemodynamic instability developed in one patient. Ultrasound-guided percutaneous core needle biopsy of splenic lesions is a safe method for achieving a histopathologic diagnosis and can be considered as an alternative to splenectomy in patients with a high risk of splenectomy-related complications.

  16. Ultrasound-guided percutaneous core needle biopsy of splenic lesions

    International Nuclear Information System (INIS)

    Park, SangIk; Shin, Yong Moon; Won, Hyung Jin; Kim, Pyo Nyun; Lee, Moon Gyu

    2017-01-01

    To evaluate the safety and efficacy of ultrasound-guided percutaneous core needle biopsy of splenic lesions. This retrospective study included 30 patients who underwent percutaneous core needle biopsy of their splenic lesions using 18- or 20-gauge needles between January 2001 and July 2016 in a single tertiary care center. The characteristics of the splenic lesions were determined by reviewing the ultrasound and computed tomography examinations. Acquisition rate and diagnostic accuracy were calculated, using pathologic results of the splenectomy specimen, clinical course and/or imaging follow-up as a reference standard. Post-procedure complications were identified from electronic medical records, laboratory findings and computed tomography images. Seventy-three specimens were obtained from the 30 patients and splenectomy was performed in 2 patients. Twenty-nine of the 30 patients had focal splenic lesions, while the remaining patient had homogeneous splenomegaly. Acquisition rate and diagnostic accuracy were 80.0% (24/30) and 76.7% (23/30), respectively. Perisplenic hemorrhage without hemodynamic instability developed in one patient. Ultrasound-guided percutaneous core needle biopsy of splenic lesions is a safe method for achieving a histopathologic diagnosis and can be considered as an alternative to splenectomy in patients with a high risk of splenectomy-related complications

  17. In vitro autoradiographic studies for determination of mitotic index and labelling index in biopsies of the human oral mucosa

    International Nuclear Information System (INIS)

    Etzbach, T.

    1980-01-01

    In order to find the most favourable method of incubation for in-vitro autoradiographies of biopsies of human oral mucosa, tissue biopsies were taken from oral mucosa transplants of 10 patients (7 females, 3 males) and either fixed or incubated at once. The author then investigated the mitotic index of the non-incubated tissue specimens, the mitotic index of the tissue specimens incubated in atmospheric conditions (A), and the mitotic index of the tissue specimens incubated under pressure (B). Simultaneously, autoradiographs of the incubated tissue specimens were prepared in order to determine their labelling indices. The mitotic indices of the non-incubated tissue specimen were found to differ significantly from those of the A-incubated tissue specimens. A similar difference was found between the mitotic indices of the A- and B-incubated tissue biopsies. Further, the labelling indices of A autoradiographs differed significantly from the labelling indices of B autoradiographs. The findings suggest that incubation with an excess oxygen pressure of 2 bar is the method of choice for in-vitro studies of human oral mucosa as the cells retain their specific activity and cell processes will continue unhindered. Further, the findings can be transferred to in-vivo conditions with a reasonable error rate. (orig./MG) [de

  18. The value of bladder mapping and prostatic urethra biopsies for detection of carcinoma in situ (CIS).

    Science.gov (United States)

    Gudjónsson, Sigurdur; Bläckberg, Mats; Chebil, Gunilla; Jahnson, Staffan; Olsson, Hans; Bendahl, Pär-Ola; Månsson, Wiking; Liedberg, Fredrik

    2012-07-01

    It is well known that CIS is a major risk factor for muscle-invasive bladder cancer and that this entity can be difficult to diagnose. Taking cold-cup mapping biopsies from different areas of the bladder (BMAP) is commonly used in patients at risk of harbouring CIS. The diagnostic accuracy of this approach has not been assessed until now. By using the CIS found in the cystoprostatectomy specimen as an indicator of the true occurrence of CIS and comparing that with the findings of BMAP, it is clear that the sensitivity of BMAP to detect CIS when present is low and that negative findings should be considered unreliable. To assess the value of bladder mapping and prostatic urethra biopsies for detection of urothelial carcinoma in situ (CIS). CIS of the urinary bladder is a flat high-grade lesion of the mucosa associated with a significant risk of progression to muscle-invasive disease. CIS is difficult to identify on cystoscopy, and definite diagnosis requires histopathology. Traditionally, if CIS is suspected, multiple cold-cup biopsies are taken from the bladder mucosa, and resection biopsies are obtained from the prostatic urethra in males. This approach is often called bladder mapping (BMAP). The accuracy of BMAP as a diagnostic tool is not known. Male patients with bladder cancer scheduled for cystectomy underwent cold-cup bladder biopsies (sidewalls, posterior wall, dome, trigone), and resection biopsies were taken from the prostatic urethra. After cystectomy, the surgical specimen was investigated in a standardised manner and subsequently compared with the BMAP biopsies for the presence of CIS. The histopathology reports of 162 patients were analysed. CIS was detected in 46% of the cystoprostatectomy specimens, and multiple (≥2) CIS lesions were found in 30%. BMAP (cold-cup bladder biopsies + resection biopsies from the prostatic urethra) provided sensitivity of 51% for any CIS, and 55% for multiple CIS lesions. The cold-cup biopsies for CIS in the bladder

  19. A Simple Model to Assess the Probability of Invasion in Ductal Carcinoma In Situ of the Breast Diagnosed by Needle Biopsy

    Directory of Open Access Journals (Sweden)

    Oldřich Coufal

    2014-01-01

    Full Text Available Objectives. The aim of the study was to develop a clinical prediction model for assessing the probability of having invasive cancer in the definitive surgical resection specimen in patients with biopsy diagnosis of ductal carcinoma in situ (DCIS of the breast, to facilitate decision making regarding axillary surgery. Methods. In 349 women with DCIS, predictors of invasion in the definitive resection specimen were identified. A model to predict the probability of invasion was developed and subsequently simplified to divide patients into two risk categories. The model’s performance was validated on another patient population. Results. Multivariate logistic regression revealed four independent predictors of invasion: (i suspicious (microinvasion in the biopsy specimen; (ii visibility of the lesion on ultrasonography; (iii size of the lesion on mammography >30 mm; (iv clinical palpability of the lesion. The actual frequency of invasion in the high-risk patient group in the test and validation population was 52.6% and 48.3%, respectively; in the low-risk group it was 16.8% and 7.1%, respectively. Conclusion. The model proved to have good performance. In patients with a low probability of invasion, an axillary procedure can be omitted without a substantial risk of additional surgery.

  20. Comparison of CT and PET/CT for biopsy guidance in oncological patients

    Energy Technology Data Exchange (ETDEWEB)

    Cerci, Juliano J.; Bogoni, Mateos; Cunha Pereira, Carlos; Cerci, Rodrigo J.; Krauzer, Cassiano; Vicente Vitola, Joao [Quanta - Diagnostico e Terapia, Curitiba, PR (Brazil); Tabacchi, Elena; Fanti, Stefano [University Hospital S. Orsola-Malpighi, Nuclear Medicine Department, Bologna (Italy); Delbeke, Dominique [Vanderbilt University, Nashville, TN (United States); Giacometti Sakamoto, Danielle [Byori - Laboratorio de Patologia, Curitiba (Brazil)

    2017-08-15

    To compare FDG PET/CT and CT for the guidance of percutaneous biopsies with histological confirmation of lesions. We prospectively evaluated 323 patients of whom 181 underwent FDG PET/CT-guided biopsy (total 188 biopsies) and 142 underwent CT-guided biopsy (total 146 biopsies). Biopsies were performed using the same PET/CT scanner with a fluoroscopic imaging system. Technical feasibility, clinical success and complication rates in the two groups were evaluated. Of the 188 biopsies with PET/CT guidance, 182 (96.8%) were successful with conclusive tissue samples obtained and of the 146 biopsies with CT guidance, 137 (93.8%) were successful. Therefore, 6 of 188 biopsies (3.1%) with PET/CT guidance and 9 of 146 (6.1%) with CT guidance were inconclusive (p = 0.19). Due to inconclusive histological results, 4 of the 188 lesions (2.1%) were rebiopsied with PET/CT guidance and 3 of 146 lesions (2.0%) were rebiopsied with CT guidance. Histology demonstrated that 142 of 188 lesions (75.5%) were malignant, and 40 (21.2%) were benign in the PET/CT-guided group, while 89 of 146 lesions (60.9%) were malignant and 48 (32.8%) were benign in the CT-guided group (p = 0.004 and 0.01, respectively). Patients with a histological diagnosis of benign lesion had no recurrence of disease with a minimum of 6 months follow-up. Of the 188 PET/CT-guided biopsies, 6 (3.1%) were repeat biopsies due to a previous nondiagnostic CT-guided biopsy performed in a different diagnostic centre. The interval between the two biopsies was less than a month in all cases. Histology revealed five malignant lesions and one benign lesion among these. The complication rate in the PET/CT-guided biopsy group was 12.7% (24 of 188), while in the CT-guided group, was 9.5% (14 of 146, p = 0.26). Therefore, there was no significant difference in complication rates between PET/CT and CT guidance. PET/CT-guided biopsy is already known to be a feasible and accurate method in the diagnostic work-up of suspected malignant

  1. Comparison of CT and PET/CT for biopsy guidance in oncological patients

    International Nuclear Information System (INIS)

    Cerci, Juliano J.; Bogoni, Mateos; Cunha Pereira, Carlos; Cerci, Rodrigo J.; Krauzer, Cassiano; Vicente Vitola, Joao; Tabacchi, Elena; Fanti, Stefano; Delbeke, Dominique; Giacometti Sakamoto, Danielle

    2017-01-01

    To compare FDG PET/CT and CT for the guidance of percutaneous biopsies with histological confirmation of lesions. We prospectively evaluated 323 patients of whom 181 underwent FDG PET/CT-guided biopsy (total 188 biopsies) and 142 underwent CT-guided biopsy (total 146 biopsies). Biopsies were performed using the same PET/CT scanner with a fluoroscopic imaging system. Technical feasibility, clinical success and complication rates in the two groups were evaluated. Of the 188 biopsies with PET/CT guidance, 182 (96.8%) were successful with conclusive tissue samples obtained and of the 146 biopsies with CT guidance, 137 (93.8%) were successful. Therefore, 6 of 188 biopsies (3.1%) with PET/CT guidance and 9 of 146 (6.1%) with CT guidance were inconclusive (p = 0.19). Due to inconclusive histological results, 4 of the 188 lesions (2.1%) were rebiopsied with PET/CT guidance and 3 of 146 lesions (2.0%) were rebiopsied with CT guidance. Histology demonstrated that 142 of 188 lesions (75.5%) were malignant, and 40 (21.2%) were benign in the PET/CT-guided group, while 89 of 146 lesions (60.9%) were malignant and 48 (32.8%) were benign in the CT-guided group (p = 0.004 and 0.01, respectively). Patients with a histological diagnosis of benign lesion had no recurrence of disease with a minimum of 6 months follow-up. Of the 188 PET/CT-guided biopsies, 6 (3.1%) were repeat biopsies due to a previous nondiagnostic CT-guided biopsy performed in a different diagnostic centre. The interval between the two biopsies was less than a month in all cases. Histology revealed five malignant lesions and one benign lesion among these. The complication rate in the PET/CT-guided biopsy group was 12.7% (24 of 188), while in the CT-guided group, was 9.5% (14 of 146, p = 0.26). Therefore, there was no significant difference in complication rates between PET/CT and CT guidance. PET/CT-guided biopsy is already known to be a feasible and accurate method in the diagnostic work-up of suspected malignant

  2. Current status of core needle biopsy of the thyroid

    Energy Technology Data Exchange (ETDEWEB)

    Baek, Jung Hwan [Dept. of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of)

    2017-04-15

    Thyroid nodules are a common clinical problem. Fine-needle aspiration (FNA) and large-needle biopsy have been used to diagnose thyroid nodules. Before the 1980s, large-needle biopsy was the standard procedure for the thyroid, but FNA became the standard diagnostic tool in the 1980s because it is a safe procedure that leads to accurate diagnoses. With advances in core needle biopsy (CNB) devices (i.e., spring-activated core needles) and development of high-resolution ultrasound, it has become possible to make accurate diagnoses while minimizing complications. Although 18- to 21-gauge core needles can be used to biopsy thyroid nodules, 18-gauge needles are most commonly used in Korea. The relationships among the size of the needle, the number of core specimens, and diagnostic accuracy have not yet been conclusively established, but the general tendency is that thinner needles cause less damage to the normal thyroid, but allow a smaller amount of thyroid tissue to be biopsied to be obtained. These relationships may be validated in the future.

  3. CT-guided core-needle biopsy in omental pathology

    International Nuclear Information System (INIS)

    Pombo, F.; Rodriguez, E.; Martin, R.; Lago, M.

    1997-01-01

    Purpose: To assess the accuracy and clinical usefulness of CT-guided core-needle biopsy in the diagnosis of omental pathology. Material and Methods: We retrospectively reviewed the results of CT-guided percutaneous core biopsies in 25 patients with focal (n=2) or diffuse (n=23) omental pathology. These results were compared to the final diagnoses as determined by laparotomy (n=15), laparoscopic biopsy (n=3), endoscopic biopsy (n=1), or by the results of percutaneous biopsy and clinical-radiological and bacteriological modalities (n=6). The final diagnoses showed 4 patients with isolated omental pathology and 21 with widespread peritoneal involvement. The CT-guided biopsies were performed with 1.0=1.8-mm Surecut core-needles. Results: In 16 patients, the final diagnosis was metastatic adenocarcinoma - with the primary tumor sites in the ovary (n=3), stomach (n=1), appendix (n=2), and unknown (n=10). In the remaining 9 patients, the final diagnosis was hepatocellular carcinoma, lymphoma, and mesothelioma in 1 patient each; tuberculosis in 5; and actinomycosis in 1. Sufficient histological (n=16) or cytological (n=8) material was obtained by CT biopsy in 24/25 (96%) cases; the specimen was insufficient for diagnosis in 1 case. In differentiating benign from malignant disease, CT-guided biopsy showed a sensitivity, specificity and accuracy of respectively 89.5%, 100% and 92%. It gave a specific diagnosis in 78.9% (15/19) of patients with malignant conditions and in 50% (3/6) of patients with benign disorders. There were no biopsy-related complications. Conclusion: CT-guided percutaneous core-needle biopsy of the omentum is a safe, useful and highly accurate procedure for diagnosing malignant omental pathology. (orig.)

  4. The usefulness of the transrectal ultrasonography in the diagnosis of the prostate cancer : comparison with systemic sextant biopsy

    International Nuclear Information System (INIS)

    Moon, Min Hoan; Seong, Chang Kyu; Jeong, Jun Yong; Choi, Huck Jae; Sim, Jung Suk; Kim, Seung Hyup

    2001-01-01

    To retrospectively compared the usefulness of the transrectal ultrasonography LEAVE A SPACE(TRUS) and systemic sextant biopsy in the diagnosis of prostate cancer. A total of 84 patients with clinical and laboratory findings suggestive of prostate cancer underwent TRUS and systemic sextant biopsy. Nine patients with diffuse prostatic lesion had been excluded from the list. Following sonographic evaluation, additional targeted biopsy for the focal lesion was performed in 14 patients. A total of 464 biopsy specimens were obtained and retrospectively compared with the sonographic findings. For cancer, the sensitivity, specificity and false-positive rate of TRUS were 48%, 97% and 53%, respectively. The hypoechoic nodules seen in prostate cancer were more commonly located in the outer half of the peripheral zone of the prostate, while most BPH lesions were located in the inner half of this zone. Between prostate cancer and BPH there was statistically significant difference in the location of hypoechoic nodules revealed by TRUS (p=0.01). The location of the hypoechoic nodules provides useful information for differentiating between BPH nodules and malignant prostatic nodules and may reduce the false-positive rate of TRUS in the diagnosis of prostate cancer

  5. The diagnostic value of ultrasound-guided fine-needle aspiration biopsy in breast masses

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Nam Hee; Lim, Hyun Yang; Park, Noh Kyong; Tae, Seok; Shin, Kyung Ja; Lee, Sang Chun [Seoul Red Cross Hospital, Seoul (Korea, Republic of)

    1993-05-15

    Real-time ultrasound-guided fine-needle aspiration biopsy in 137 solid breast masses was performed. Sonographic findings were categorized into three groups and aspirates were categorized into three cytologic groups. The cytologic results was reported benign masses (cytologic group 1) in 71 cases (52%). malignant masses (cytologic group 2 and 3) in 44 cases (32%) and insufficient specimens in 22 case (16%). Insufficient specimens were treated as benign masses. Excisional biopsy in 44 malignant masses and 3 benign masses according to cytologic results, clinical findings and follow up study was performed. The result was reported 41 malignant masses and 6 benign masses. Based on cytologic criteria, sensitivity for detection of malignancy was 93% and specificity was 94%. In conclusion, the high specificity provided by ultrasound-guided fine-needle aspiration biopsy could markedly reduce unnecessary surgical excisions for benign masses and it should be routinely performed, since it can give physical and emotional benefits to patients and lead to earlier and cost effective diagnosis of breast cancer.

  6. The diagnostic value of ultrasound-guided fine-needle aspiration biopsy in breast masses

    International Nuclear Information System (INIS)

    Lee, Nam Hee; Lim, Hyun Yang; Park, Noh Kyong; Tae, Seok; Shin, Kyung Ja; Lee, Sang Chun

    1993-01-01

    Real-time ultrasound-guided fine-needle aspiration biopsy in 137 solid breast masses was performed. Sonographic findings were categorized into three groups and aspirates were categorized into three cytologic groups. The cytologic results was reported benign masses (cytologic group 1) in 71 cases (52%). malignant masses (cytologic group 2 and 3) in 44 cases (32%) and insufficient specimens in 22 case (16%). Insufficient specimens were treated as benign masses. Excisional biopsy in 44 malignant masses and 3 benign masses according to cytologic results, clinical findings and follow up study was performed. The result was reported 41 malignant masses and 6 benign masses. Based on cytologic criteria, sensitivity for detection of malignancy was 93% and specificity was 94%. In conclusion, the high specificity provided by ultrasound-guided fine-needle aspiration biopsy could markedly reduce unnecessary surgical excisions for benign masses and it should be routinely performed, since it can give physical and emotional benefits to patients and lead to earlier and cost effective diagnosis of breast cancer

  7. Pseudolipomatosis in Endometrial Specimens Does Not Represent Uterine Perforation.

    Science.gov (United States)

    Heller, Alexis

    2017-02-01

    Specimens of endometrial biopsies can sometimes present with an artifact within blood, composed of optically clear vacuoles mimicking adipose tissue, pseudolipomatosis. This artifact can be mistaken for adipose tissue and lead to an overdiagnosis of uterine perforation. We describe the case of pseudolipomatosis seen within the evacuated products of conception from a missed abortion. Areas of vacuolization in the blood clot mimicked adipose tissue. However, the vacuoles varied in size and did not contain adipocytes. Familiarity with this artifact will lead to avoidance of overdiagnosis of adipose tissue and uterine perforation in curettage specimens.

  8. Comparative Tissue Proteomics of Microdissected Specimens Reveals Novel Candidate Biomarkers of Bladder Cancer*

    Science.gov (United States)

    Chen, Chien-Lun; Chung, Ting; Wu, Chih-Ching; Ng, Kwai-Fong; Yu, Jau-Song; Tsai, Cheng-Han; Chang, Yu-Sun; Liang, Ying; Tsui, Ke-Hung; Chen, Yi-Ting

    2015-01-01

    More than 380,000 new cases of bladder cancer are diagnosed worldwide, accounting for ∼150,200 deaths each year. To discover potential biomarkers of bladder cancer, we employed a strategy combining laser microdissection, isobaric tags for relative and absolute quantitation labeling, and liquid chromatography-tandem MS (LC-MS/MS) analysis to profile proteomic changes in fresh-frozen bladder tumor specimens. Cellular proteins from four pairs of surgically resected primary bladder cancer tumor and adjacent nontumorous tissue were extracted for use in two batches of isobaric tags for relative and absolute quantitation experiments, which identified a total of 3220 proteins. A DAVID (database for annotation, visualization and integrated discovery) analysis of dysregulated proteins revealed that the three top-ranking biological processes were extracellular matrix organization, extracellular structure organization, and oxidation-reduction. Biological processes including response to organic substances, response to metal ions, and response to inorganic substances were highlighted by up-expressed proteins in bladder cancer. Seven differentially expressed proteins were selected as potential bladder cancer biomarkers for further verification. Immunohistochemical analyses showed significantly elevated levels of three proteins—SLC3A2, STMN1, and TAGLN2—in tumor cells compared with noncancerous bladder epithelial cells, and suggested that TAGLN2 could be a useful tumor tissue marker for diagnosis (AUC = 0.999) and evaluating lymph node metastasis in bladder cancer patients. ELISA results revealed significantly increased urinary levels of both STMN1 and TAGLN2 in bladder cancer subgroups compared with control groups. In comparisons with age-matched hernia urine specimens, urinary TAGLN2 in bladder cancer samples showed the largest fold change (7.13-fold), with an area-under-the-curve value of 0.70 (p < 0.001, n = 205). Overall, TAGLN2 showed the most significant

  9. Biopsy system for CT-guided biopsies

    International Nuclear Information System (INIS)

    Onik, G.; Cosman, E.; Wells, T.; Goldberg, H.I.; Moss, A.; Costello, P.; Kane, R.

    1987-01-01

    CT stereotaxic brain biopsies have made brain biopsies safe and minimally invasive. CT-guided biopsies of the body, however, have traditionally used a hand-guidance method. CT biopsy guidance systems for the body have recently become available that have similar capabilities as those of brain biopsy systems. To compare the clinical utility of stereotaxically guided biopsies with hand-guided biopsies, the authors prospectively compared 40 biopsies performed with each method. In the stereotaxic method, a localizor grid was placed on the patient to define a reference point, and a frame was used to guide the needle along the intended path. Computer software programs calculated complex paths from one scan plane to another. Although the results disclosed no significant differences in lesion size or path length between the two groups, the stereotaxically guided biopsies required 75% fewer needle manipulations to hit the intended target. Consequently, the stereotaxically guided biopsies required 40% less time and 80% fewer localization scans to find the biopsy needle than did the hand-guided biopsies

  10. Relation between reflux of bile acids into the stomach and gastric mucosal atrophy, intestinal metaplasia in biopsy specimens.

    Science.gov (United States)

    Matsuhisa, Takeshi; Tsukui, Taku

    2012-05-01

    During endoscopic examinations we collected fluid in the stomach that included reflux fluid from the duodenum, and assessed the effect of quantitatively determined bile acids on glandular atrophy and intestinal metaplasia using biopsy specimens. A total of 294 outpatients were enrolled in this study. Total bile acid concentration was measured by an enzyme immunoassay. Glandular atrophy and intestinal metaplasia scores were graded according to the Updated Sydney System. An effect of refluxed bile acids on atrophy and intestinal metaplasia was shown in the high-concentration reflux group in comparison with the control group. However, when the odds ratios (ORs) were calculated according to whether Helicobacter pylori (H. pylori) infection was present, no significant associations were shown between reflux bile acids and atrophy in either the H. pylori-positive cases or -negative cases. The same was true for intestinal metaplasia in the H. pylori-positive cases, whereas intestinal metaplasia was more pronounced in the high-concentration reflux group in the H. pylori-negative cases (OR 2.4, 95%CI 1.1-5.6). We could not clarify the effect of the reflux of bile acids into the stomach in the progression of atrophy. High-concentration bile acids had an effect on the progression of intestinal metaplasia in the H. pylori-negative cases.

  11. CT-Guided Transgluteal Biopsy for Systematic Random Sampling of the Prostate in Patients Without Rectal Access.

    Science.gov (United States)

    Goenka, Ajit H; Remer, Erick M; Veniero, Joseph C; Thupili, Chakradhar R; Klein, Eric A

    2015-09-01

    The objective of our study was to review our experience with CT-guided transgluteal prostate biopsy in patients without rectal access. Twenty-one CT-guided transgluteal prostate biopsy procedures were performed in 16 men (mean age, 68 years; age range, 60-78 years) who were under conscious sedation. The mean prostate-specific antigen (PSA) value was 11.4 ng/mL (range, 2.3-39.4 ng/mL). Six had seven prior unsuccessful transperineal or transurethral biopsies. Biopsy results, complications, sedation time, and radiation dose were recorded. The mean PSA values and number of core specimens were compared between patients with malignant results and patients with nonmalignant results using the Student t test. The average procedural sedation time was 50.6 minutes (range, 15-90 minutes) (n = 20), and the mean effective radiation dose was 8.2 mSv (median, 6.6 mSv; range 3.6-19.3 mSv) (n = 13). Twenty of the 21 (95%) procedures were technically successful. The only complication was a single episode of gross hematuria and penile pain in one patient, which resolved spontaneously. Of 20 successful biopsies, 8 (40%) yielded adenocarcinoma (Gleason score: mean, 8; range, 7-9). Twelve biopsies yielded nonmalignant results (60%): high-grade prostatic intraepithelial neoplasia (n = 3) or benign prostatic tissue with or without inflammation (n = 9). Three patients had carcinoma diagnosed on subsequent biopsies (second biopsy, n = 2 patients; third biopsy, n = 1 patient). A malignant biopsy result was not significantly associated with the number of core specimens (p = 0.3) or the mean PSA value (p = 0.1). CT-guided transgluteal prostate biopsy is a safe and reliable technique for the systematic random sampling of the prostate in patients without a rectal access. In patients with initial negative biopsy results, repeat biopsy should be considered if there is a persistent rise in the PSA value.

  12. Inflammation, Adenoma and Cancer: Objective Classification of Colon Biopsy Specimens with Gene Expression Signature

    Directory of Open Access Journals (Sweden)

    Orsolya Galamb

    2008-01-01

    Full Text Available Gene expression analysis of colon biopsies using high-density oligonucleotide microarrays can contribute to the understanding of local pathophysiological alterations and to functional classification of adenoma (15 samples, colorectal carcinomas (CRC (15 and inflammatory bowel diseases (IBD (14. Total RNA was extracted, amplified and biotinylated from frozen colonic biopsies. Genome-wide gene expression profile was evaluated by HGU133plus2 microarrays and verified by RT-PCR. We applied two independent methods for data normalization and used PAM for feature selection. Leave one-out stepwise discriminant analysis was performed. Top validated genes included collagenIVα1, lipocalin-2, calumenin, aquaporin-8 genes in CRC; CD44, met proto-oncogene, chemokine ligand-12, ADAM-like decysin-1 and ATP-binding casette-A8 genes in adenoma; and lipocalin-2, ubiquitin D and IFITM2 genes in IBD. Best differentiating markers between Ulcerative colitis and Crohn's disease were cyclin-G2; tripartite motif-containing-31; TNFR shedding aminopeptidase regulator-1 and AMICA. The discriminant analysis was able to classify the samples in overall 96.2% using 7 discriminatory genes (indoleamine-pyrrole-2,3-dioxygenase, ectodermal-neural cortex, TIMP3, fucosyltransferase-8, collectin sub-family member 12, carboxypeptidase D, and transglutaminase-2. Using routine biopsy samples we successfully performed whole genomic microarray analysis to identify discriminative signatures. Our results provide further insight into the pathophysiological background of colonic diseases. The results set up data warehouse which can be mined further.

  13. Biopsy

    Science.gov (United States)

    ... Oropharynx lesion biopsy Pleural needle biopsy Polyp biopsy Rectal biopsy Renal biopsy Salivary gland biopsy Skin lesion ... Copyright 1997-2018, A.D.A.M., Inc. Duplication for commercial use must be authorized in writing ...

  14. Fast MRI-guided vacuum-assisted breast biopsy: initial experience.

    Science.gov (United States)

    Liberman, Laura; Morris, Elizabeth A; Dershaw, D David; Thornton, Cynthia M; Van Zee, Kimberly J; Tan, Lee K

    2003-11-01

    The purpose of this study was to evaluate a new method for performing MRI-guided vacuum-assisted breast biopsy in a study of lesions that had subsequent surgical excision. SUBJECTS AND METHODS. Twenty women scheduled for MRI-guided needle localization and surgical biopsy were prospectively entered in the study. MRI-guided biopsy was performed with a vacuum-assisted probe, followed by placement of a localizing clip, and then needle localization for surgical excision. Vacuum-assisted biopsy and surgical histology were correlated. Vacuum-assisted biopsy was successfully performed in 19 (95%) of the 20 women. The median size of 27 MRI-detected lesions that had biopsy was 1.0 cm (range, 0.4-6.4 cm). Cancer was present in eight (30%) of 27 lesions and in six (32%) of 19 women; among these eight cancers, five were infiltrating and three were ductal carcinoma in situ (DCIS). Among these 27 lesions, histology was benign at vacuum-assisted biopsy and at surgery in 19 (70%), cancer at vacuum-assisted biopsy in six (22%), atypical ductal hyperplasia at vacuum-assisted biopsy and DCIS at surgery in one (4%), and benign at vacuum-assisted biopsy with surgery showing microscopic DCIS that was occult at MRI in one (4%). The median time to perform vacuum-assisted biopsy of a single lesion was 35 min (mean, 35 min; range, 24-48 min). Placement of a localizing clip, attempted in 26 lesions, was successful in 25 (96%) of 26, and the clip was retrieved on specimen radiography in 22 (96%) of 23. One complication occurred: a hematoma that resolved with compression. MRI-guided vacuum-assisted biopsy is a fast, safe, and accurate alternative to surgical biopsy for breast lesions detected on MRI.

  15. MR-guided biopsies of undetermined liver lesions: technique and results; MRT-gezielte perkutane Biopsie bei unklaren fokalen Leberlaesionen: Technik und Ergebnisse

    Energy Technology Data Exchange (ETDEWEB)

    Zangos, S.; Kiefl, D.; Eichler, K.; Engelmann, K.; Heller, M.; Herzog, C.; Mack, M.G.; Jacobi, V.; Vogl, T.J. [Inst. fuer Diagnostische und Interventionelle Radiologie, Johann-Wolfgang-Goethe-Univ. Frankfurt (Germany)

    2003-05-01

    Purpose: To evaluate safety and precision of liver tumor biopsies performed in an open low field system using different sequence techniques. Materials and Methods: In 47 patients with liver tumors, MR-guided biopsies were performed in a low field system (0.2 Tesla, Magnetom Open, Siemens) using two different sequences. The procedure was monitored with T1-weighted FLASH sequences (TR/TE = 100/9; 70 ) in all patients and with FISP-Rotated-Keyhole-sequence (TR/TE = 18/8; 90 ) in additional 20 patients. After positioning of the needle tip in the tumors, 166 biopsy specimens were acquired with 16 G cutting needles (Somatex{sup *}). The diameter of the biopsied lesions ranged from 1 to 10 cm (mean diameter 3.2 cm). Visibility of the needles and precision of the biopsies were evaluated. Results: All interventional biopsies were performed without vascular or organ injuries. Adequate specimens for histologic interpretation were obtained in 42 cases (89.3%). The biopsy results were non-specific in 2 patients (4.2%) and the lesions missed in 3 patients (6.3%). Mean in-room time was 35 minutes and the intervention time was 8.3 minutes. T1-weighted FLASH images proved optimal for confirming needle-tip placement during the biopsies or punctures. Organs, tumors and vessels were easily identified. The FISP sequence proved to be inferior in visualizing vessels and tumors. Conclusion: MR-guided liver biopsies are safely and precisely performed using T1-weighted FLASH-sequences with sufficient visualization of the lesions and might be complementary to US- or CT-guided biopsies. (orig.) [German] Zielsetzung: Evaluierung der Sicherheit und Genauigkeit MRT-gezielter Leberbiopsien unter Verwendung verschiedener Sequenzen. Methoden: Bei 47 Patienten mit unklaren Leberlaesionen wurden in einem offenen 0,2-Tesla-MR-System (Magnetom Open, Siemens) bildgesteuerte Biopsien unter Verwendung von zwei verschiedenen Sequenzen durchgefuehrt. Die Bildgebung erfolgte bei allen Patienten mittels T

  16. Confocal Microscopy of Unfixed Breast Needle Core Biopsies: A Comparison to Fixed and Stained Sections

    Directory of Open Access Journals (Sweden)

    Zavislan James M

    2009-08-01

    Full Text Available Abstract Background Needle core biopsy, often in conjunction with ultrasonic or stereotactic guided techniques, is frequently used to diagnose breast carcinoma in women. Confocal scanning laser microscopy (CSLM is a technology that provides real-time digital images of tissues with cellular resolution. This paper reports the progress in developing techniques to rapidly screen needle core breast biopsy and surgical specimens at the point of care. CSLM requires minimal tissue processing and has the potential to reduce the time from excision to diagnosis. Following imaging, specimens can still be submitted for standard histopathological preparation. Methods Needle core breast specimens from 49 patients were imaged at the time of biopsy. These lesions had been characterized under the Breast Imaging Reporting And Data System (BI-RADS as category 3, 4 or 5. The core biopsies were imaged with the CSLM before fixation. Samples were treated with 5% citric acid and glycerin USP to enhance nuclear visibility in the reflectance confocal images. Immediately following imaging, the specimens were fixed in buffered formalin and submitted for histological processing and pathological diagnosis. CSLM images were then compared to the standard histology. Results The pathologic diagnoses by standard histology were 7 invasive ductal carcinomas, 2 invasive lobular carcinomas, 3 ductal carcinomas in-situ (CIS, 21 fibrocystic changes/proliferative conditions, 9 fibroadenomas, and 5 other/benign; two were excluded due to imaging difficulties. Morphologic and cellular features of benign and cancerous lesions were identified in the confocal images and were comparable to standard histologic sections of the same tissue. Conclusion CSLM is a technique with the potential to screen needle core biopsy specimens in real-time. The confocal images contained sufficient information to identify stromal reactions such as fibrosis and cellular proliferations such as intra-ductal and

  17. Confocal Microscopy of Unfixed Breast Needle Core Biopsies: A Comparison to Fixed and Stained Sections

    Science.gov (United States)

    2009-01-01

    Background Needle core biopsy, often in conjunction with ultrasonic or stereotactic guided techniques, is frequently used to diagnose breast carcinoma in women. Confocal scanning laser microscopy (CSLM) is a technology that provides real-time digital images of tissues with cellular resolution. This paper reports the progress in developing techniques to rapidly screen needle core breast biopsy and surgical specimens at the point of care. CSLM requires minimal tissue processing and has the potential to reduce the time from excision to diagnosis. Following imaging, specimens can still be submitted for standard histopathological preparation. Methods Needle core breast specimens from 49 patients were imaged at the time of biopsy. These lesions had been characterized under the Breast Imaging Reporting And Data System (BI-RADS) as category 3, 4 or 5. The core biopsies were imaged with the CSLM before fixation. Samples were treated with 5% citric acid and glycerin USP to enhance nuclear visibility in the reflectance confocal images. Immediately following imaging, the specimens were fixed in buffered formalin and submitted for histological processing and pathological diagnosis. CSLM images were then compared to the standard histology. Results The pathologic diagnoses by standard histology were 7 invasive ductal carcinomas, 2 invasive lobular carcinomas, 3 ductal carcinomas in-situ (CIS), 21 fibrocystic changes/proliferative conditions, 9 fibroadenomas, and 5 other/benign; two were excluded due to imaging difficulties. Morphologic and cellular features of benign and cancerous lesions were identified in the confocal images and were comparable to standard histologic sections of the same tissue. Conclusion CSLM is a technique with the potential to screen needle core biopsy specimens in real-time. The confocal images contained sufficient information to identify stromal reactions such as fibrosis and cellular proliferations such as intra-ductal and infiltrating carcinoma, and

  18. [When to ask for a skin biopsy in a patient with leg ulcer? Retrospective study of 143 consecutive biopsies].

    Science.gov (United States)

    Stansal, A; Khayat, K; Duchatelle, V; Tella, E; Gautier, V; Sfeir, D; Attal, R; Lazareth, I; Priollet, P

    2018-02-01

    A vascular cause is found in around 85% of leg ulcer patients, but non-vascular causes are also observed. Their diagnosis is based on a set of clinical arguments and skin biopsy with histological analysis. The aim of this study was to analyze the results of these biopsies and to find common criteria for ulcers whose skin biopsies had led to the diagnosis of a non-vascular ulcer. A retrospective study was carried out on the analysis of 143 skin biopsies of leg ulcers. The reasons for the biopsy were mainly atypical clinical signs and/or the lack of improvement in care after 6 months, as advocated by the French health authorities. The skin biopsies led to a diagnosis of non-vascular ulcer in 4.9% of cases (7/143), including skin cancer (n=5, 3.5%), cutaneous leishmaniasis (n=1, 0.7%) and Pyoderma gangrenosum (n=1, 0.7%). The univariate statistical analysis revealed that an elevated rim and abnormal excessive granulation tissue were significantly more frequently found in these ulcers. All patients with a positive skin biopsy had associated vascular involvement. This study found a 5% rate of non-vascular causes of ulcers, mainly skin cancer. Elevated rims and abnormal excessive granulation tissue were the unusual features most commonly found in these ulcers. All patients whose skin biopsy revealed a non-vascular cause had associated vascular involvement. This information confirms the need to perform a skin biopsy, even in the presence of a vascular disease. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  19. Computed tomography-guided percutaneous biopsy of pancreatic masses using pneumodissection; Biopsia percutanea de massas pancreaticas guiada por tomografia computadorizada com pneumodisseccao

    Energy Technology Data Exchange (ETDEWEB)

    Tyng, Chiang Jeng; Bitencourt, Almir Galvao Vieira; Almeida, Maria Fernanda Arruda; Barbosa, Paula Nicole Vieira; Martins, Eduardo Bruno Lobato; Junior, Joao Paulo Kawaoka Matushita; Chojniak, Rubens, E-mail: chiangjengtyng@gmail.com [Hospital A.C. Camargo, Sao Paulo, SP (Brazil). Dept. de Imagem; Coimbra, Felipe Jose Fernandez [Hospital A.C. Camargo, Sao Paulo, SP (Brazil). Dept. de Cirurgia Abdominal

    2013-05-15

    Objective: to describe the technique of computed tomography-guided percutaneous biopsy of pancreatic tumors with pneumodissection. Materials and methods: in the period from June 2011 to May 2012, seven computed tomography guided percutaneous biopsies of pancreatic tumors utilizing pneumodissection were performed in the authors' institution. All the procedures were performed with an automatic biopsy gun and coaxial system with Tru-core needles. The biopsy specimens were histologically assessed. Results: in all the cases the pancreatic mass could not be directly approached by computed tomography without passing through major organs and structures. The injection of air allowed the displacement of adjacent structures and creation of a safe coaxial needle pathway toward the lesion. Biopsy was successfully performed in all the cases, yielding appropriate specimens for pathological analysis. Conclusion: Pneumodissection is a safe, inexpensive and technically easy approach to perform percutaneous biopsy in selected cases where direct access to the pancreatic tumor is not feasible. (author)

  20. Molecular markers: Implications for cytopathology and specimen collection.

    Science.gov (United States)

    VanderLaan, Paul A

    2015-08-01

    Cytologic specimens obtained through minimally invasive biopsy techniques are increasingly being used as principle diagnostic specimens for tumors arising in multiple sites. The number and scope of ancillary tests performed on these specimens have grown substantially over the past decade, including many molecular markers that not only can aid in formulating accurate and specific diagnoses but also can provide prognostic or therapeutic information to help direct clinical decisions. Thus, the cytopathologist needs to ensure that adequate material is collected and appropriately processed for the study of relevant molecular markers, many of which are specific to tumor site. This brief review covers considerations for effective cytologic specimen collection and processing to ensure diagnostic and testing success. In addition, a general overview is provided of molecular markers pertinent to tumors from a variety of sites. The recognition of these established and emerging molecular markers by cytopathologists is an important step toward realizing the promise of personalized medicine. © 2015 American Cancer Society.

  1. Eosinophilic esophageal myositis diagnosed by endoscopic ultrasound-guided fine-needle aspiration biopsy: a case report.

    Science.gov (United States)

    Igarashi, Ryo; Irisawa, Atsushi; Shibukawa, Goro; Yamabe, Akane; Fujisawa, Mariko; Sato, Ai; Maki, Takumi; Arakawa, Noriyuki; Yoshida, Yoshitsugu; Yamamoto, Shogo; Ikeda, Tsunehiko

    2016-10-01

    Eosinophilic esophagitis (EoE) is diagnosed by microscopic findings of eosinophilic infiltration into the squamous epithelium. In contrast, another disease concept termed "eosinophilic esophageal myositis (EoEM)" has been proposed, whereby there is eosinophilic infiltration into the muscularis propria instead. A 60-year-old man was referred to our hospital for chest pain, dysphagia, and several episodes of esophageal food impaction. Although EoE was suspected based on clinical features, biopsy specimens showed no mucosal eosinophilic infiltration. Endoscopic ultrasound (EUS) showed thickening of the muscularis propria layer and subsequent EUS-guided fine-needle aspiration biopsy (EUS-FNA) revealed eosinophilic infiltration into the muscularis propria. Although the patient's symptoms gradually improved after steroid administration, complete remission was not achieved after 1 year of treatment. This case may reflect a disorder distinct from typical EoE based on eosinophilic infiltration of the muscularis propria but not the squamous epithelium, and we, therefore, diagnosed it as EoEM using the EUS-FNA findings as reference.

  2. Percutaneous transhepatic cholangiographic forceps biopsy in pathologic diagnosis for obstructive jaundice

    International Nuclear Information System (INIS)

    Han Xinwei; Li Yongdong; Ma Bo; Xing Gusheng; Wu Gang; Gao Xuemei; Ma Nan

    2004-01-01

    Objective: To evaluate the technical feasibility and sensitivity of percutaneous transhepatic cholangiographic forceps biopsy in bile duct diseases. Methods: Between April 2001 and March 2003, 65 consecutive patients (36 men and 29 women; age range 33-88 years, mean 54 years) with obstructive jaundice underwent transluminal forceps biopsy or/and brush during percutaneous transhepatic cholangiography, percutaneous transhepatic cholangiography and drainage, or placement of stents. The technique was performed through an existing percutaneous transhepatic tract. Multiple specimens were obtained after passing the biopsy forceps or brush into a long 8-French sheath, and the specimens were fixed with formalin for pathologic or cytologic diagnosis. Statistical analysis was performed with the χ 2 test or Fisher exact probability, and P 2 =5.919, P=0.015). The cyctologic diagnosis was acquired in 43 of 58 patients with brush biopsy. Pathologic reports included cholangioadenocarcinoma (n=36), cholangiosquam-ocarcinoma (n=1), pancreatic adenocarcinoma (n=1), hepatocellular carcinoma (n=2), metastatic carcinoma (n=2), zoogloea aggregation (n=1), and negative results (n=15). The sensitivity rate of brush biopsy was 74.14%. Sensitivity of brush in the 45 patients with cholangiocarcinoma was higher than in the 11 patients with malignant tumors other than cholangiocarcinoma (82.22% vs 45.45%, χ 2 =4.563, P=0.033). Sensitivity of forceps biopsy in the 65 patients was higher than that of brush in the 58 patients (χ 2 =4.754, P=0.029). Conclusion: Percutaneous transhepatic cholangiobiopsy is a safe and minimal invasive procedure with no pain and low complication that is easy to perform with no addition trauma through a transhepatic biliary drainage tract. It is an effective, economic, accurate, and reliable new approach, which is safe and easy to perform in acquiring the pathologic diagnosis worthy to spread extensively. (authors)

  3. Antiendomysial and antihuman recombinant tissue transglutaminase antibodies in the diagnosis of coeliac disease: a biopsy-proven European multicentre study.

    Science.gov (United States)

    Collin, Pekka; Kaukinen, Katri; Vogelsang, Harald; Korponay-Szabó, Ilma; Sommer, Rudolf; Schreier, Elisabeth; Volta, Umberto; Granito, Alessandro; Veronesi, Lorenza; Mascart, Françoise; Ocmant, Annick; Ivarsson, Anneli; Lagerqvist, Carina; Bürgin-Wolff, Annemarie; Hadziselimovic, Faruk; Furlano, Raoul I; Sidler, Marc A; Mulder, Chris J J; Goerres, Marije S; Mearin, M Luisa; Ninaber, Maarten K; Gudmand-Høyer, Eivind; Fabiani, Elisabetta; Catassi, Carlo; Tidlund, Helena; Alainentalo, Lisbeth; Mäki, Markku

    2005-01-01

    To investigate the value of serum antitissue transglutaminase IgA antibodies (IgA-TTG) and IgA antiendomysial antibodies (IgA-EMA) in the diagnosis of coeliac disease in cohorts from different geographical areas in Europe. The setting allowed a further comparison between the antibody results and the conventional small-intestinal histology. A total of 144 cases with coeliac disease [median age 19.5 years (range 0.9-81.4)], and 127 disease controls [median age 29.2 years (range 0.5-79.0)], were recruited, on the basis of biopsy, from 13 centres in nine countries. All biopsy specimens were re-evaluated and classified blindly a second time by two investigators. IgA-TTG were determined by ELISA with human recombinant antigen and IgA-EMA by an immunofluorescence test with human umbilical cord as antigen. The quality of the biopsy specimens was not acceptable in 29 (10.7%) of 271 cases and a reliable judgement could not be made, mainly due to poor orientation of the samples. The primary clinical diagnosis and the second classification of the biopsy specimens were divergent in nine cases, and one patient was initially enrolled in the wrong group. Thus, 126 coeliac patients and 106 controls, verified by biopsy, remained for final analysis. The sensitivity of IgA-TTG was 94% and IgA-EMA 89%, the specificity was 99% and 98%, respectively. Serum IgA-TTG measurement is effective and at least as good as IgA-EMA in the identification of coeliac disease. Due to a high percentage of poor histological specimens, the diagnosis of coeliac disease should not depend only on biopsy, but in addition the clinical picture and serology should be considered.

  4. Percutaneous transluminal forceps biopsy in patients suspected of having malignant biliary obstruction: factors influencing the outcomes of 271 patients

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jung Gu; Jung, Gyoo-Sik; Yun, Jong Hyouk [Kosin University College of Medicine, Department of Radiology, Seo-gu, Busan (Korea, Republic of); Yun, Byung Chul; Lee, Sang Uk; Han, Byung Hoon [Kosin University College of Medicine, Department of Internal Medicine, Busan (Korea, Republic of); Ko, Ji Ho [Busan Medical Center, Department of Radiology, Busan (Korea, Republic of)

    2017-10-15

    To evaluate predictive factors for false-negative diagnosis of percutaneous forceps biopsies in patients suspected of having a malignant biliary obstruction Two hundred seventy one consecutive patients with obstructive jaundice underwent percutaneous forceps biopsy. In each patient, three to five specimens (mean, 3.5 specimens) were collected from the lesion. The final diagnosis for each patient was confirmed with pathologic findings at surgery, additional histocytologic data, or clinical and radiologic follow-up. Univariate and multivariate logistic regression analysis was used to identify risk factors associated with false-negative diagnosis. One hundred ninety four of 271 biopsies resulted in correct diagnoses of malignancy, while 20 biopsy diagnoses were proved to be true-negative. There were 57 false-negative diagnoses and no false-positive diagnoses. The diagnostic performance of transluminal forceps biopsy in malignant biliary obstructions was as follows: sensitivity, 77.2%; specificity, 100%; and accuracy, 78.9%; positive predictive value, 100%, negative predictive value; 25.9%. Periampullary segment of common bile duct, intrahepatic bile duct and metastatic disease were the significant risk factors of false-negative diagnosis. Percutaneous forceps biopsy provides relatively high accuracy in the diagnosis of malignant biliary obstructions. The predictive factors of false-negative biopsy were determined to be biopsy site and origin of primary tumour. (orig.)

  5. Prevalence Of Helicobacter pylori In Gastric Biopsies Of Patients ...

    African Journals Online (AJOL)

    The prevalence of Helicobacter pylori infection as seen at the University of Benin Teaching Hospital (UBTH) Benin City Nigeria was 16% which was significant using the students T-test (P<0.05). Eighty one gastric biopsy specimens received in the microbiology laboratory were cultured on chocolate agar. Of the H. pylori ...

  6. Ultrasound-guided percutaneous biopsy of digestive tract lesions

    International Nuclear Information System (INIS)

    Gil, S.; Martin, I.; Ballesteros, J. M.; Gomez, C.; Marco, S. F.; Fernandez, P.

    1999-01-01

    To present our experience in ultrasound-guided percutaneous biopsy of lesions located in the digestive tract. We performed ultrasound-guided percutaneous biopsy in 14 patients (10 men and 4 women) ranging in age from 7 to 71 years (mean; 519 years). The lesions were located throughout the digestive tract, from the pyriform sinus to the sigmoid colon. The biopsy was carried out with a 5 MHz convex probe equipped with a device to direct the needle. An 18G automatic needle or a 20G Chiba needle was used to obtain specimens for histological study in every case, and additional samples were collected with a 22G needle for cytological examination in 13 of the patients. The ultrasound images corresponded to pseudokidney in 9 cases and extrinsic masses in 5. The diagnosis was obtained from the histological examination in every case (100%) and from cytology in 6 (44.4%), the latter results were less specific. The only complication corresponded to a case of bilioperitoneum. Ultrasound-guided percutaneous biopsy is a suitable technique for the histological diagnosis of those lesions of the digestive tract that are visible in ultrasound images, but that for some reason can not be examined by endoscopic biopsy. (Author) 20 refs

  7. Histopathological Features Of Granulomatous Skin Diseases : An Analysis Of 22 Skin Biopsies

    OpenAIRE

    Dhar Subhra; Dhar Sandipan

    2002-01-01

    In the present study, skin biopsies were analysed for histopathological (HP) changes in 22 patients with various granulomatous dermatoses. In 6 specimens, HP features were diagnostic of BT leprosy, in 1 each of BB, BL and historid LL. The HP features were was lupus valugaris (LV) in 6 biopsies, tuberculosis verrucosa cutis (TBVC) in 2, sarcoidosis in 3 and sporotrichosis in remaining 2. The study reiterated the usefulness of HP examination of all suspected cases of granulomatous skin diseases.

  8. Temporal artery biopsies in south-east Scotland: a five year review.

    Science.gov (United States)

    Gajree, S; Borooah, S; Dhillon, N; Goudie, C; Smith, C; Aspinall, P; Dhillon, B

    2017-06-01

    Temporal artery biopsy is the gold standard investigation for the diagnosis of giant cell arteritis. The aim of this retrospective study was to investigate the use of temporal artery biopsy in diagnosing giant cell arteritis in south-east Scotland over a five-year period. We aimed to quantify success rates, and predictive factors for a positive biopsy, as well as compare the different specialities performing the biopsies. The data should enable the development of better criteria for referral for investigation of giant cell arteritis. Methods Patients were identified using a database of temporal artery biopsies generated by the pathology department in NHS Lothian (south east Scotland), for all biopsies examined between January 2010 and December 2015. An electronic patient record was used to retrospectively examine the records of patients in the database. Results A total of 715 biopsies were included in the study, of which 250 (35.0%) showed features of giant cell arteritis. The main predictors for a positive biopsy were age at biopsy, specialty performing biopsy, erythrocyte sedimentation rate, jaw claudication/pain, and ophthalmic symptoms. The most important predictor of a positive biopsy was erythrocyte sedimentation rate. The length of biopsy was not found to be a predictor of positive biopsy; however, diameter of biopsy was predictive. Conclusions We have shown that many temporal artery biopsies are negative, and finding ways to reduce the number of patients unnecessarily undergoing biopsy will be essential in reducing workload and streamlining services. This study demonstrates some key predictive factors for patients with positive biopsies. The study also shows that a large proportion of biopsies taking place do not result in the recommended length of specimen, but this does not necessarily reduce the likelihood of a positive biopsy.

  9. Stereotactic breast biopsy with a biopsy gun

    International Nuclear Information System (INIS)

    Parker, S.H.; Lovin, J.; Luethke, J.; Jobe, W.E.; Hopper, K.D.; Yakes, W.F.

    1989-01-01

    With the recent introduction of stereotactic mammographic localizing devices, the authors have been performing histologic core needle breast biopsies in which the Bard biopsy gun is used in conjunction with sterotactic guidance. The authors have performed 60 breast gun biopsies with 16-gauge and 18-gauge biopsy-cut needles. These biopsies were followed immediately by traditional surgical excision. Pathologic results correlated well in 52 of the 60 patients, including 10 of 13 cancers. Three of the eight negative correlations occurred when diagnosis was made on gun biopsy but not on surgical biopsy. The stereotactic- guided gun biopsies appear to approach the surgical gold standard, decrease patient discomfort and potential disfigurement, lower the cost of breast biopsy, and lower the threshold necessary to perform breast biopsy

  10. Transperineal template-guided prostate saturation biopsies in men with suspicion of prostate cancer: a pilot study from Pakistan.

    Science.gov (United States)

    Mehmood, K; Mubarak, M; Dhar, M; Rafi, M; Kinsella, J

    2017-12-01

    Traditionally, transrectal ultrasound (TRUS)-guided biopsies are done for the diagnosis of prostate cancer (PCa) in Pakistan. The transperineal template-guided saturation biopsy (TTSB) approach has been recently introduced in Pakistan and we share diagnostic yields and pathological findings of specimens taken for PCa diagnosis in men with elevated serum total prostate specific antigen (PSA) and negative TRUS-guided prostate biopsies. In all, 16 patients investigated at the Department of Urology, Sindh Institute of Urology and Transplantation (SIUT), underwent TTSB. The mean age of patients was 67.8 ± 8.8 (range: 55 - 84) years. The median PSA was 9.5 (IQR: 7.9 - 19.8) ng/ ml. The duration of symptoms before biopsy ranged from 1 month to 144 months. The prostate was enlarged with mean weight of 73.5 ± 55.5 g. Histopathology revealed PCa in 5 of 16 (31.2%) cases. The Gleason score was 6 (3+3), 7 (3+4) and 8 (4+4) in 1 case each (6.3%) and 10 (5+5) in 2 cases (12.5%). At least two cores were positive in all positive cases. None of the patients required antibiotics post-procedure. In conclusion, the TTSB technique is a promising option for patients with elevated PSA level and negative transrectal prostate biopsies for the detection of PCa in our setting.

  11. 11-gauge vacuum assisted directional biopsy of breast calcifications, using upright stereotactic guidance

    International Nuclear Information System (INIS)

    Nisbet, A.P.; Borthwick-Clarke, A.; Scott, N.

    2000-01-01

    To assess the use of a prototype vacuum assisted biopsy device on a standard upright mammography unit, using a slightly modified digital stereotactic add-on component. A group comprised of 42 sequential patients, who had been recalled from an asymptomatic mammographic screening programme, were studied. All 42 were recalled for assessment of small clusters of microcalcification, graded as indeterminate. Group 1 (21 patients) were biopsied using 14-gauge automated large core needle biopsy. Group 2 (21 patients) were biopsied using 11-gauge vacuum assisted biopsy. Both groups had mammographic guidance on the same upright mammographic unit (Siemens 3000), with Opdima Digital Stereotactic add-on. A total of 86% of specimen radiographs in Group 2 patients (vacuum assisted biopsy) showed successful sampling of the calcifications, compared to 62% of Group 1 patients (14-gauge automated large core biopsies). This study shows that vacuum assisted biopsy is possible using upright stereotactic mammography units. The technique shows promise as a biopsy tool, offering larger cores compared to 14-gauge automated large core biopsy, while requiring less space and lower purchase price compared to dedicated prone biopsy tables. The technique also offers access to biopsy in patients with posterior lesions and for patients who cannot tolerate prone positioning

  12. Computed tomography-guided core-needle biopsy of lung lesions: an oncology center experience

    Energy Technology Data Exchange (ETDEWEB)

    Guimaraes, Marcos Duarte; Fonte, Alexandre Calabria da; Chojniak, Rubens, E-mail: marcosduarte@yahoo.com.b [Hospital A.C. Camargo, Sao Paulo, SP (Brazil). Dept. of Radiology and Imaging Diagnosis; Andrade, Marcony Queiroz de [Hospital Alianca, Salvador, BA (Brazil); Gross, Jefferson Luiz [Hospital A.C. Camargo, Sao Paulo, SP (Brazil). Dept. of Chest Surgery

    2011-03-15

    Objective: The present study is aimed at describing the experience of an oncology center with computed tomography guided core-needle biopsy of pulmonary lesions. Materials and Methods: Retrospective analysis of 97 computed tomography-guided core-needle biopsy of pulmonary lesions performed in the period between 1996 and 2004 in a Brazilian reference oncology center (Hospital do Cancer - A.C. Camargo). Information regarding material appropriateness and the specific diagnoses were collected and analyzed. Results: Among 97 lung biopsies, 94 (96.9%) supplied appropriate specimens for histological analyses, with 71 (73.2%) cases being diagnosed as malignant lesions and 23 (23.7%) diagnosed as benign lesions. Specimens were inappropriate for analysis in three cases. The frequency of specific diagnosis was 83 (85.6%) cases, with high rates for both malignant lesions with 63 (88.7%) cases and benign lesions with 20 (86.7%). As regards complications, a total of 12 cases were observed as follows: 7 (7.2%) cases of hematoma, 3 (3.1%) cases of pneumothorax and 2 (2.1%) cases of hemoptysis. Conclusion: Computed tomography-guided core needle biopsy of lung lesions demonstrated high rates of material appropriateness and diagnostic specificity, and low rates of complications in the present study. (author)

  13. Mixed germ cell tumor of mediastinum/lung masquerading as hemangioma in fine needle biopsy

    Directory of Open Access Journals (Sweden)

    Rathna Nuti

    2013-01-01

    Full Text Available The histological predominance of one component in a germ cell tumor can lead to a mistaken diagnosis. Here, we describe a mediastinal teratoma with predominant vascular proliferation (>90% which on fine needle biopsy was diagnosed as a pulmonary hemangioma. Later, resection specimen revealed other components constituting ~4%, changing the diagnosis while illustrating theimportance of careful evaluation. A 37-year-old Caucasian male with shortness of breath, weight loss, and history of recently resolved pneumonia was diagnosed with hemangioma, after a computed tomography guided fine needle biopsy of a -16.3-cm mediastinal pulmonary mass revealed abundant benign vascular elements. Following tumor excision, ~94% of the sample exhibited predominant vascular elementsThe mass also exhibited rare focal areas of malignant epithelium in a reticular arrangement and undifferentiated pleomorphic cells associated with vascular invasion. These atypical epithelial cells were positive for CD30, pan CK, AFP, β-HCG and CD 117, thusprocuring a diagnosis of mediastinal mixed germ cell tumor. Although mixed germ cell tumors consist of various tissue types, diagnosis can be easily overlooked if one component dominates. Therefore, obtaining adequate representative neoplasm samples, and sectioning the samples thoroughly, searching for coexisting tissue types is critical for accurate diagnosis.

  14. Vertical vs. transverse sections of scalp biopsy specimens: a pilot study on the comparison of the diagnostic value of two techniques in alopecia.

    Science.gov (United States)

    Özcan, D; Özen, Ö; Seçkin, D

    2011-12-01

    Using both vertical and transverse sections is preferred for histopathological diagnosis of alopecia. However, in cases in which only a single biopsy is taken, it is not clear which type of sectioning is better. To compare the diagnostic value of transverse and vertical sections. In total, 53 patients with alopecia were enrolled in the study. Two biopsies were taken from each patient, and cut into either transverse or vertical sections. The clinical and histopathological findings were evaluated together for the definitive diagnosis. After the study period, a pathologist randomly re-evaluated the sections. We compared the histopathological diagnoses with the definitive diagnoses, and determined the sensitivity and specificity of each method. A definitive diagnosis was made for 47 patients (88.7%). Of these, 30 (63.8%) had noncicatricial and 17 (36.2%) had cicatricial alopecia, and the diagnosis was made by transverse and vertical sections for 43 (91.5%) and 39 (88%), respectively (P > 0.05; sensitivity; 91.5% vs. 82%). All 30 patients with noncicatricial alopecia were diagnosed by transverse sections, and 25 (83.3%) of the 30 were diagnosed with vertical sections (P = 0.05; sensitivity 100% vs. 83.3%). Of the 17 patients with cicatricial alopecia, 13 (76.5%) and 14 (82.4%) patients were diagnosed by transverse and vertical sections, respectively (P > 0.05; sensitivity 76.5% vs. 82.4%). Five patients with lichen planopilaris were diagnosed by vertical sections, and one by transverse sections. There were several limitations to the study: (i) statistical subtype analysis could be performed only for alopecia areata; (ii) no conclusion could be drawn about the interobserver reliability of two sections; and (iii) having the pathologist-blinded study performed retrospectively might have caused a recall bias. If only a single biopsy specimen is available, it may be preferable to have transverse sections in cases of suspected noncicatricial alopecia, and vertical sections in

  15. Evaluation of diagnostic methods for the detection of Helicobacter pylori in gastric biopsy specimens of dyspeptic patients

    Directory of Open Access Journals (Sweden)

    Ivy Bastos Ramis

    2012-09-01

    Full Text Available Helicobacter pylori infects nearly 50% of the world's population. This microorganism is accepted as the most important agent of gastritis and as a risk factor for peptic ulcer disease and gastric adenocarcinoma. Currently many diagnostic methods exist for detecting H. pylori, however they all have limitations, thus it is recommend a combination of at least two methods. The aim of this study was to evaluate diagnostic methods, such as in-house urease test, culture and Polymerase Chain Reaction (PCR, for the detection of the H. pylori in gastric biopsy specimens of 144 dyspeptic patients, using as gold standard the association between histology and rapid urease test. According to the gold standard used in this study, 48 (33.3% patients were infected with H. pylori, while 96 (66.7% were classified as not infected. The in-house urease test and the PCR were the most sensitive methods (100%, followed by culture (85.4%. However, the in-house urease test and the culture were the most specific (100%, followed by PCR (75%. In conclusion, this study showed that, in comparison with the combination of histology and rapid urease test, the in-house urease test and the PCR presented 100% of sensitivity in the diagnosis of gastric infection by H. pylori, while the in-house urease test and the culture reached 100% of specificity. These finding suggest that the combination of two or more methods may improve the accuracy of the H. pylori detection.

  16. Percutaneous computed tomography-guided core needle biopsy of soft tissue tumors: results and correlation with surgical specimen analysis

    Energy Technology Data Exchange (ETDEWEB)

    Chojniak, Rubens; Grigio, Henrique Ramos; Bitencourt, Almir Galvao Vieira; Pinto, Paula Nicole Vieira; Tyng, Chiang J.; Cunha, Isabela Werneck da; Aguiar Junior, Samuel; Lopes, Ademar, E-mail: chojniak@uol.com.br [Hospital A.C. Camargo, Sao Paulo, SP (Brazil)

    2012-09-15

    Objective: To evaluate the efficacy of percutaneous computed tomography (CT)-guided core needle biopsy of soft tissue tumors in obtaining appropriate samples for histological analysis, and compare its diagnosis with the results of the surgical pathology as available. Materials and Methods: The authors reviewed medical records, imaging and histological reports of 262 patients with soft-tissue tumors submitted to CT-guided core needle biopsy in an oncologic reference center between 2003 and 2009. Results: Appropriate samples were obtained in 215 (82.1%) out of the 262 patients. The most prevalent tumors were sarcomas (38.6%), metastatic carcinomas (28.8%), benign mesenchymal tumors (20.5%) and lymphomas (9.3%). Histological grading was feasible in 92.8% of sarcoma patients, with the majority of them (77.9%) being classified as high grade tumors. Out of the total sample, 116 patients (44.3%) underwent surgical excision and diagnosis confirmation. Core biopsy demonstrated 94.6% accuracy in the identification of sarcomas, with 96.4% sensitivity and 89.5% specificity. A significant intermethod agreement about histological grading was observed between core biopsy and surgical resection (p < 0.001; kappa = 0.75). Conclusion: CT-guided core needle biopsy demonstrated a high diagnostic accuracy in the evaluation of soft tissue tumors as well as in the histological grading of sarcomas, allowing an appropriate therapeutic planning (author)

  17. Single-Pass Percutaneous Liver Biopsy for Diffuse Liver Disease Using an Automated Device: Experience in 154 Procedures

    International Nuclear Information System (INIS)

    Rivera-Sanfeliz, Gerant; Kinney, Thomas B.; Rose, Steven C.; Agha, Ayad K.M.; Valji, Karim; Miller, Franklin J.; Roberts, Anne C.

    2005-01-01

    Purpose: To describe our experience with ultrasound (US)-guided percutaneous liver biopsies using the INRAD 18G Express core needle biopsy system.Methods: One hundred and fifty-four consecutive percutaneous core liver biopsy procedures were performed in 153 men in a single institution over 37 months. The medical charts, pathology reports, and radiology files were retrospectively reviewed. The number of needle passes, type of guidance, change in hematocrit level, and adequacy of specimens for histologic analysis were evaluated.Results: All biopsies were performed for histologic staging of chronic liver diseases. The majority of patients had hepatitis C (134/153, 90.2%). All patients were discharged to home after 4 hr of postprocedural observation. In 145 of 154 (94%) biopsies, a single needle pass was sufficient for diagnosis. US guidance was utilized in all but one of the procedures (153/154, 99.4%). The mean hematocrit decrease was 1.2% (44.1-42.9%). Pain requiring narcotic analgesia, the most frequent complication, occurred in 28 of 154 procedures (18.2%). No major complications occurred. The specimens were diagnostic in 152 of 154 procedures (98.7%).Conclusions: Single-pass percutaneous US-guided liver biopsy with the INRAD 18G Express core needle biopsy system is safe and provides definitive pathologic diagnosis of chronic liver disease. It can be performed on an outpatient basis. Routine post-biopsy monitoring of hematocrit level in stable, asymptomatic patients is probably not warranted

  18. Gene Expression Profiles in Paired Gingival Biopsies from Periodontitis-Affected and Healthy Tissues Revealed by Massively Parallel Sequencing

    Science.gov (United States)

    Båge, Tove; Lagervall, Maria; Jansson, Leif; Lundeberg, Joakim; Yucel-Lindberg, Tülay

    2012-01-01

    Periodontitis is a chronic inflammatory disease affecting the soft tissue and bone that surrounds the teeth. Despite extensive research, distinctive genes responsible for the disease have not been identified. The objective of this study was to elucidate transcriptome changes in periodontitis, by investigating gene expression profiles in gingival tissue obtained from periodontitis-affected and healthy gingiva from the same patient, using RNA-sequencing. Gingival biopsies were obtained from a disease-affected and a healthy site from each of 10 individuals diagnosed with periodontitis. Enrichment analysis performed among uniquely expressed genes for the periodontitis-affected and healthy tissues revealed several regulated pathways indicative of inflammation for the periodontitis-affected condition. Hierarchical clustering of the sequenced biopsies demonstrated clustering according to the degree of inflammation, as observed histologically in the biopsies, rather than clustering at the individual level. Among the top 50 upregulated genes in periodontitis-affected tissues, we investigated two genes which have not previously been demonstrated to be involved in periodontitis. These included interferon regulatory factor 4 and chemokine (C-C motif) ligand 18, which were also expressed at the protein level in gingival biopsies from patients with periodontitis. In conclusion, this study provides a first step towards a quantitative comprehensive insight into the transcriptome changes in periodontitis. We demonstrate for the first time site-specific local variation in gene expression profiles of periodontitis-affected and healthy tissues obtained from patients with periodontitis, using RNA-seq. Further, we have identified novel genes expressed in periodontitis tissues, which may constitute potential therapeutic targets for future treatment strategies of periodontitis. PMID:23029519

  19. Metagenomic analysis reveals presence of Treponema denticola in a tissue biopsy of the Iceman.

    Directory of Open Access Journals (Sweden)

    Frank Maixner

    Full Text Available Ancient hominoid genome studies can be regarded by definition as metagenomic analyses since they represent a mixture of both hominoid and microbial sequences in an environment. Here, we report the molecular detection of the oral spirochete Treponema denticola in ancient human tissue biopsies of the Iceman, a 5,300-year-old Copper Age natural ice mummy. Initially, the metagenomic data of the Iceman's genomic survey was screened for bacterial ribosomal RNA (rRNA specific reads. Through ranking the reads by abundance a relatively high number of rRNA reads most similar to T. denticola was detected. Mapping of the metagenome sequences against the T. denticola genome revealed additional reads most similar to this opportunistic pathogen. The DNA damage pattern of specifically mapped reads suggests an ancient origin of these sequences. The haematogenous spread of bacteria of the oral microbiome often reported in the recent literature could already explain the presence of metagenomic reads specific for T. denticola in the Iceman's bone biopsy. We extended, however, our survey to an Iceman gingival tissue sample and a mouth swab sample and could thereby detect T. denticola and Porphyrimonas gingivalis, another important member of the human commensal oral microflora. Taken together, this study clearly underlines the opportunity to detect disease-associated microorganisms when applying metagenomics-enabled approaches on datasets of ancient human remains.

  20. Histopathological Features Of Granulomatous Skin Diseases : An Analysis Of 22 Skin Biopsies

    Directory of Open Access Journals (Sweden)

    Dhar Subhra

    2002-01-01

    Full Text Available In the present study, skin biopsies were analysed for histopathological (HP changes in 22 patients with various granulomatous dermatoses. In 6 specimens, HP features were diagnostic of BT leprosy, in 1 each of BB, BL and historid LL. The HP features were was lupus valugaris (LV in 6 biopsies, tuberculosis verrucosa cutis (TBVC in 2, sarcoidosis in 3 and sporotrichosis in remaining 2. The study reiterated the usefulness of HP examination of all suspected cases of granulomatous skin diseases.

  1. Using an AMACR (P504S)/34betaE12/p63 cocktail for the detection of small focal prostate carcinoma in needle biopsy specimens.

    Science.gov (United States)

    Jiang, Zhong; Li, Cuizhen; Fischer, Andrew; Dresser, Karen; Woda, Bruce A

    2005-02-01

    We assessed the usefulness of immunohistochemical analysis with a 3-antibody cocktail (alpha-methylacyl coenzyme A racemase [AMACR, or P504S], 34betaE12, p63) and a double-chromogen reaction for detection of limited prostate cancer in 138 needle biopsy specimens, including 82 with small foci of prostatic adenocarcinoma and 56 benign prostates. When carcinoma was present, red cytoplasmic granular staining (AMACR) in the malignant glands and cells and dark brown nuclear (p63) and cytoplasmic (34betaE12) staining in basal cells of adjacent nonmalignant glands were found. Of 82 cases of small foci of prostatic adenocarcinoma, 78 (95%) expressed AMACR; all malignant glands were negative for basal cell staining. All benign glands adjacent to malignant glands were recognized easily by basal cell marker positivity and little or no AMACR expression. No benign glands were simultaneously positive for AMACR and negative for basal cell markers (specificity, 100%). There were no differences in intensity and numbers of positive glands with double-chromogen staining compared with using 1-color staining. Our results indicate that immunohistochemistry with a 3-antibody cocktail and double chromogen is a simple and easy assay that can be used as a routine test, which overcomes the problems of studying small lesions in prostate needle biopsies with multiple immunohistochemical stains.

  2. Stereotaxic percutaneous core biopsy versus surgical biopsy of nonpalpable breast lesions using a standard mammographic table with an add-on device

    International Nuclear Information System (INIS)

    Levin, M.F.; Papoff, W.J.; Doan, L.; Eliasziw, M.

    2001-01-01

    To determine the accuracy of using a regular mammographic table with an add-on device for biopsy of nonpalpable breast lesions in women in a community hospital setting. During a 3-year period, 70 consenting women (39-80 years of age) with a nonpalpable mammographically suspicious lesion on routine screening mammography underwent 14-gauge automated percutaneous core biopsies, immediate needle localization and lumpectomy. The needle and surgical biopsy results were independently classified into 1 of 5 categories: cancer, fibroadenomal fibrocystic change, normal or other. The procedure was well tolerated, and all core specimens yielded adequate tissue for pathologic evaluation. There were 3 episodes of vasovagal reaction. There was complete agreement in histologic findings in 64 cases (91%), including 22 of 24 cancers (92%). The overall agreement for categorizing lesions was 91% (k 0.88), and there was 97% agreement (k = 0.94) for the classification of cancer versus benign lesion. The results are similar to those of studies performed with dedicated prone equipment. Stereotaxic core biopsies can be done safely and accurately in a community hospital setting with relatively inexpensive nondedicated mammographic equipment. (author)

  3. Stereotaxic percutaneous core biopsy versus surgical biopsy of nonpalpable breast lesions using a standard mammographic table with an add-on device

    Energy Technology Data Exchange (ETDEWEB)

    Levin, M.F.; Papoff, W.J.; Doan, L.; Eliasziw, M. [St. Thomas-Elgin General Hospital, St. Thomas, Ontario (Canada)

    2001-02-01

    To determine the accuracy of using a regular mammographic table with an add-on device for biopsy of nonpalpable breast lesions in women in a community hospital setting. During a 3-year period, 70 consenting women (39-80 years of age) with a nonpalpable mammographically suspicious lesion on routine screening mammography underwent 14-gauge automated percutaneous core biopsies, immediate needle localization and lumpectomy. The needle and surgical biopsy results were independently classified into 1 of 5 categories: cancer, fibroadenomal fibrocystic change, normal or other. The procedure was well tolerated, and all core specimens yielded adequate tissue for pathologic evaluation. There were 3 episodes of vasovagal reaction. There was complete agreement in histologic findings in 64 cases (91%), including 22 of 24 cancers (92%). The overall agreement for categorizing lesions was 91% (k 0.88), and there was 97% agreement (k = 0.94) for the classification of cancer versus benign lesion. The results are similar to those of studies performed with dedicated prone equipment. Stereotaxic core biopsies can be done safely and accurately in a community hospital setting with relatively inexpensive nondedicated mammographic equipment. (author)

  4. The diagnostic ability of an additional midline peripheral zone biopsy in transrectal ultrasonography-guided 12-core prostate biopsy to detect midline prostate cancer

    Directory of Open Access Journals (Sweden)

    Inpyeong Hwang

    2016-01-01

    Full Text Available Purpose: The goal of this study was to evaluate the diagnostic effect of adding a midline peripheral zone (PZ biopsy to the 12-core biopsy protocol used to diagnose prostate cancer (PC, and to assess the clinical and pathologic characteristics of midline-positive PC in order to identify a potential subgroup of patients who would require midline PZ biopsy. Methods: This study included 741 consecutive patients who underwent a transrectal ultrasonography-guided, 12-core prostate biopsy with an additional midline core biopsy between October 2012 and December 2013. We grouped patients by the presence or absence of PC and subdivided patients with PC based on the involvement of the midline core. The clinical characteristics of these groups were compared, including serum prostate-specific antigen (PSA concentrations, PSA density, and pathological features in the biopsy specimens. Results: PC was detected in 289 patients (39.0%. Among the PC patients, 66 patients (22.8% had midline PC. No patients were diagnosed with PC based only on a midline core. The Gleason scores, number of positive cores, tumor core length, serum PSA concentrations, and PSA density were significantly higher in patients with midline-positive PC (P<0.001. Furthermore, significant cancer was more frequent in the midline-positive group (98.5% vs. 78.0%. Conclusion: Patients showing a positive result for PC in a midline PZ biopsy were more likely to have multiple tumors or large-volume PC with a high tumor burden. However, our data indicated that an additional midline core biopsy is unlikely to be helpful in detecting occult midline PC.

  5. Diagnostic usefulness of endorectal magnetic resonance imaging with dynamic contrast-enhancement in patients with localized prostate cancer. Mapping studies with biopsy specimens

    International Nuclear Information System (INIS)

    Tanaka, Nobumichi; Samma, Shoji; Joko, Masanori; Akiyama, Tatsuya; Takewa, Megumi; Kitano, Satoru; Okajima, Eigoro

    1999-01-01

    New diagnostic criteria for dynamic magnetic resonance (MR) imaging in prostate cancer are presented. The diagnostic usefulness of endorectal MR imaging with dynamic contrast-enhancement in localized prostate cancer and the validity of these criteria were evaluated. Eighteen untreated patients who were suspected of localized prostate cancer were included in the study. They received endorectal dynamic MR imaging before systematic sextant needle biopsy. First, a mapping study with the findings of MR images and histopathology of biopsy specimens was performed in eight patients out of 18 to compare the difference in T2-weighted images with the endorectal coil and the body coil in the same individuals. Second, another mapping study was performed in all 18 patients by analyzing the findings of endorectal dynamic MR images. For the diagnosis of prostate cancer in MR imaging, we offered diagnostic criteria from our experience in addition to those in plain T2-weighted images from the literature. The overall diagnostic rates of endorectal dynamic MR imaging were 88.9% in accuracy, 100% in sensitivity, and 81.8% in specificity. In the comparison of the endorectal and body coils in T2-weighted images in eight patients, there was no difference in the diagnostic rates except for one more histopathologic false positive portion in endorectal MR imaging. In the second mapping study in 18 patients, the diagnostic rates were 92.6% in accuracy, 88.9% in sensitivity and 93.3% in specificity. Endorectal dynamic imaging raised the diagnostic sensitivity from 77.8 to 88.9%. The data demonstrated the validity of this diagnostic criteria and the diagnostic usefulness of endorectal dynamic MR imaging in localized prostate cancer. (author)

  6. Ultrasonography-guided Transthoracic Cutting Biopsy of Pulmonary Lesion: Diagnostic Benefits and Safety

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Mei Ah; Park, Mi Hyun [Dankook University Hospital, Cheonan (Korea, Republic of); Shin, Byung Seok [Chungnam National University Hospital, Daejeon (Korea, Republic of); Ohm, Joon Young [Bucheon St. Mary' s Hospital, Bucheon (Korea, Republic of)

    2012-06-15

    To assess the safety and usefulness of ultrasonography-guided transthoracic cutting biopsy for lung lesions. Eighty-eight patients (66 men, 22 women, mean age 59 years) with lung lesions underwent an ultrasonography(USG)-guided transthoracic cutting biopsy. The final diagnosis was based on the findings of surgery and clinical and radiological follow-ups. The histopathologic results and diagnostic accuracy of cutting biopsy were determined. Also, the complication rate was statistically evaluated according to the mass size, number of biopsies, and the presence or absence of pleural effusion. Biopsy specimens were successfully obtained in all patients. 79 of 88 lesions (89.8%) were established by histopathology. The final diagnosis was malignant in 58 and benign in 28. The remaining 2 patients were lost to follow-up. Diagnostic sensitivity for malignant lesions was 89.6% (52/58) and that for benign lesions was 96.4% (27/28). Procedure-related complications occurred in 9 patients (10.2%) including pneumothorax (n = 2) and hemoptysis (n = 7). And there was no significant difference according to mass size, number of biopsies, or presence of pleural effusion. USG-guided transthoracic cutting biopsy is a useful and safe method for technically-feasible lung lesions

  7. Ultrasonography-guided Transthoracic Cutting Biopsy of Pulmonary Lesion: Diagnostic Benefits and Safety

    International Nuclear Information System (INIS)

    Yang, Mei Ah; Park, Mi Hyun; Shin, Byung Seok; Ohm, Joon Young

    2012-01-01

    To assess the safety and usefulness of ultrasonography-guided transthoracic cutting biopsy for lung lesions. Eighty-eight patients (66 men, 22 women, mean age 59 years) with lung lesions underwent an ultrasonography(USG)-guided transthoracic cutting biopsy. The final diagnosis was based on the findings of surgery and clinical and radiological follow-ups. The histopathologic results and diagnostic accuracy of cutting biopsy were determined. Also, the complication rate was statistically evaluated according to the mass size, number of biopsies, and the presence or absence of pleural effusion. Biopsy specimens were successfully obtained in all patients. 79 of 88 lesions (89.8%) were established by histopathology. The final diagnosis was malignant in 58 and benign in 28. The remaining 2 patients were lost to follow-up. Diagnostic sensitivity for malignant lesions was 89.6% (52/58) and that for benign lesions was 96.4% (27/28). Procedure-related complications occurred in 9 patients (10.2%) including pneumothorax (n = 2) and hemoptysis (n = 7). And there was no significant difference according to mass size, number of biopsies, or presence of pleural effusion. USG-guided transthoracic cutting biopsy is a useful and safe method for technically-feasible lung lesions

  8. Case report of a 28-year-old male with the rapid progression of steroid-resistant central nervous system vasculitis diagnosed by a brain biopsy.

    Science.gov (United States)

    Takahashi, Keigo; Sato, Hideki; Hattori, Hidenori; Takao, Masaki; Takahashi, Shinichi; Suzuki, Norihiro

    2017-09-30

    A 28-year-old Japanese male without a significant past medical history presented with new-onset generalized clonic seizure and headache. A brain MRI revealed multiple enhanced lesions on both cerebral hemispheres. Laboratory exams showed no evidence of systemic inflammation or auto-immune antibodies such as ANCAs. Despite four courses of high-dose methylprednisolone pulse therapy and five treatments with plasmapheresis, his symptoms worsened and the MRI lesions progressed rapidly. During these treatments, we performed a targeted brain biopsy, that revealed histological findings consistent with a predominant angiitis of parenchymal and subdural small vessels. He was provided with diagnosis of central nervous system vasculitis (CNSV). Subsequent cyclophosphamide pulse therapy enabled a progressive successful improvement of his symptoms. While diagnostic methods for CNSV remain controversial, histological findings are thought to be more useful in obtaining a more definitive diagnosis than findings in image studies, such as MRI and angiography. We suggest that a brain biopsy should be considered during the early period of cases with suspected CNSV and rapid clinical deterioration. We also detected human herpesvirus 7 (HHV-7) using PCR technology in brain biopsy specimens, however the relationship between CNSV and HHV-7 infection is unknow.

  9. Prostate needle biopsies: interobserver variation and clinical consequences of histopathological re-evaluation

    DEFF Research Database (Denmark)

    Berg, Kasper Drimer; Toft, Birgitte Grønkaer; Røder, Martin Andreas

    2011-01-01

    Histopathological grading of prostate cancer (PCa) is associated with significant interobserver variability. This, as well as clinical consequences of histopathological re-evaluation, was investigated. In 350 patients, histopathological re-evaluations of prostate biopsies were compared with primary.......9%. The cancers were assessed with higher GS at re-evaluation in 25.0% of patients in cases with primary GS ≤ 6, while scores were devaluated in 3.0% and 10.3% of the patients with primary GS = 7 and ≥ 8, respectively. Strategies for clinical evaluation and treatment were changed as a result of the biopsy re......-evaluations in 19.7% and 13.1% of patients, respectively. Gleason scoring based on the radical prostatectomy specimen was higher than in both primary reports and re-evaluation of biopsies. Although a relatively high degree of concordance was found between biopsy assessments, the significant trend towards higher...

  10. Percutaneous ultrasound-guided renal biopsy: A Libyan experience

    Science.gov (United States)

    Mishra, A.; Tarsin, R.; ElHabbash, B.; Zagan, N.; Markus, R.; Drebeka, S.; AbdElmola, K.; Shawish, T.; Shebani, A.; AbdElmola, T.; ElUsta, A.; Ehtuish, E. F.

    2010-01-01

    This study was done to assess the safety and efficacy of ultrasound-guided percutaneous renal biopsy (PRB), to ascertain the risk factors for complications and determine the optimal period of observation. The radiologist (A.M.) at the National Organ Transplant Centre, Central Hospital, Tripoli, Libya, performed 86 PRBs between February 1, 2006, and January 31, 2008, using an automated biopsy gun with 16-gauge needle. Coagulation profile was done in all the patients. All patients were kept on strict bed rest for six hours post-procedure. Eighty six renal biopsies were performed on 78 patients referred from rheumatology department and eight post-kidney transplant recipients; 23 were males with age range 15 – 56 years and 63 females with age range 16 – 66 years. A mean of 17.5 glomeruli were present in each specimen. A glomerular yield of less than five glomeruli was seen in four biopsies. Class I lupus nephritis (LN) was seen in 1 patient, class II lupus nephritis in 7 patients, class III LN in 13 patients and class IV LN in 29 patients. All the eight renal allografts were diagnosed as acute tubular necrosis or acute interstitial rejection. The risk of post-biopsy bleeding was higher in women, older patients and higher PTT. The overall complication rate was 5.8%. Three complications were observed within six hours of biopsy. No late complication was seen. PRB under real-time ultrasound-guidance is a safe and efficacious procedure to establish the histological diagnosis and should be done as out-patient procedure. Observation time of six hours post-biopsy is optimal. PMID:20835320

  11. High-resolution, 2- and 3-dimensional imaging of uncut, unembedded tissue biopsy samples.

    Science.gov (United States)

    Torres, Richard; Vesuna, Sam; Levene, Michael J

    2014-03-01

    Despite continuing advances in tissue processing automation, traditional embedding, cutting, and staining methods limit our ability for rapid, comprehensive visual examination. These limitations are particularly relevant to biopsies for which immediate therapeutic decisions are most necessary, faster feedback to the patient is desired, and preservation of tissue for ancillary studies is most important. The recent development of improved tissue clearing techniques has made it possible to consider use of multiphoton microscopy (MPM) tools in clinical settings, which could address difficulties of established methods. To demonstrate the potential of MPM of cleared tissue for the evaluation of unembedded and uncut pathology samples. Human prostate, liver, breast, and kidney specimens were fixed and dehydrated by using traditional histologic techniques, with or without incorporation of nucleic acid fluorescent stains into dehydration steps. A benzyl alcohol/benzyl benzoate clearing protocol was substituted for xylene. Multiphoton microscopy was performed on a home-built system. Excellent morphologic detail was achievable with MPM at depths greater than 500 μm. Pseudocoloring produced images analogous to hematoxylin-eosin-stained images. Concurrent second-harmonic generation detection allowed mapping of collagen. Subsequent traditional section staining with hematoxylin-eosin did not reveal any detrimental morphologic effects. Sample immunostains on renal tissue showed preservation of normal reactivity. Complete reconstructions of 1-mm cubic samples elucidated 3-dimensional architectural organization. Multiphoton microscopy on cleared, unembedded, uncut biopsy specimens shows potential as a practical clinical tool with significant advantages over traditional histology while maintaining compatibility with gold standard techniques. Further investigation to address remaining implementation barriers is warranted.

  12. Direct identification of an HPV-16 tumor antigen from cervical cancer biopsy specimens

    Directory of Open Access Journals (Sweden)

    Derin B Keskin

    2011-12-01

    Full Text Available Persistent infection with high-risk human papilloma viruses (HPV is the worldwide cause of many cancers, including cervical, anal, vulval, vaginal, penile and oropharyngeal. Since T cells naturally eliminate the majority of chronic HPV infections by recognizing epitopes displayed on virally altered epithelium, we exploited Poisson detection mass spectrometry (MS3 to identify those epitopes and inform future T cell-based vaccine design. Nine cervical cancer biopsies from HPV-16 positive HLA-A*02 patients were obtained, histopathology determined, and E7 oncogene PCR-amplified from tumor DNA and sequenced. Conservation of E7 oncogene coding segments was found in all tumors. MS3 analysis of HLA-A*02 immunoprecipitates detected E711-19 peptide (YMLDLQPET in seven of the nine tumor biopsies. The remaining two samples were E711-19 negative and lacked the HLA-A*02 binding GILT thioreductase peptide despite possessing binding-competent HLA-A*02 alleles. Thus, the conserved E711-19 peptide is a dominant HLA-A*02 binding tumor antigen in HPV-16 transformed cervical squamous and adenocarcinomas. Findings that a minority of HLA-A*02:01 tumors lack expression of both E711-19 and a peptide from a thioreductase important in processing of cysteine-rich proteins like E7 underscore the value of physical detection, define a potential additional tumor escape mechanism and have implications for therapeutic cancer vaccine development.

  13. An Evaluation of the Diagnostic Accuracy of the Grade of Preoperative Biopsy Compared to Surgical Excision in Chondrosarcoma of the Long Bones

    Directory of Open Access Journals (Sweden)

    Robert Jennings

    2010-01-01

    Full Text Available Chondrosarcoma is the second most common primary malignant bone tumour. Distinguishing between grades is not necessarily straightforward and may alter the disease management. We evaluated the correlation between histological grading of the preoperative image-guided needle biopsy and the resection specimen of 78 consecutive cases of chondrosarcoma of the femur, humerus, and tibia. In 11 instances, there was a discrepancy in histological grade between the biopsy and surgical specimen. Therefore, there was an 85.9% (67/78 accuracy rate for pre-operative histological grading of chondrosarcoma, based on needle biopsy. However, the accuracy of the diagnostic biopsy to distinguish low-grade from high-grade chondrosarcoma was 93.6% (73/78. We conclude that accurate image-guided biopsy is a very useful adjunct in determining histological grade of chondrosarcoma and the subsequent treatment plan. At present, a multidisciplinary approach, comprising experienced orthopaedic surgeons, radiologists, and pathologists, offers the most reliable means of accurately diagnosing and grading of chondrosarcoma of long bones.

  14. Trained nurses can obtain satisfactory bone marrow aspirates and trephine biopsies.

    Science.gov (United States)

    Lawson, S; Aston, S; Baker, L; Fegan, C D; Milligan, D W

    1999-01-01

    AIMS: To assess the feasibility of training nurse practitioners to perform bone marrow aspiration and trephine biopsy, and to compare the quality of these samples with those obtained by medical staff. METHODS: A retrospective audit was undertaken of nurse practitioner and medical staff performance in bone marrow procedures in a busy haematology day unit. RESULTS: Nurse practitioners fared favourably in comparison with medical staff in performing bone marrow trephine biopsies, with mean biopsy lengths of 11 mm and 10.7 mm respectively. However, only 78% of the smears obtained by the nurses were judged technically satisfactory, compared with 91% prepared by doctors. This discrepancy was thought to be due largely to the quality of slide spreading. CONCLUSIONS: With motivated staff and a structured educational and training programme it is possible for nurse practitioners to perform the techniques of bone marrow aspiration and biopsy, and obtain specimens of satisfactory quality, thus improving efficiency of the haematology day unit and increasing quality of patient care. Images PMID:10396248

  15. Age estimation of living Indian individuals based on aspartic acid racemization from tooth biopsy specimen

    Science.gov (United States)

    Rastogi, Manu; Logani, Ajay; Shah, Naseem; Kumar, Abhishek; Arora, Saurabh

    2017-01-01

    Background: Age estimation in living individuals is imperative to amicably settle civil and criminal disputes. A biochemical method based on amino acid racemization was evaluated for age estimation of living Indian individuals. Design: Caries-free maxillary/mandibular premolar teeth (n = 90) were collected from participants with age proof documents and divided into predefined nine age groups. Materials and Methods: Dentine biopsy from the labial aspect of the tooth crown was taken with an indigenously developed microtrephine. The samples were processed and subjected to gas chromatography. Dextrorotatory:levorotatory ratios were calculated, and a regression equation was formulated. Results: Across all age groups, an error of 0 ± 4 years between protein racemization age and chronological age was observed. Conclusion: Aspartic acid racemization from dentine biopsy samples could be a viable and accurate technique for age estimation of living individuals who have attained a state of skeletal maturity. PMID:29263613

  16. Does Prebiopsy, Nonsterile Ultrasonography Gel Affect Biopsy-Site Asepsis?

    International Nuclear Information System (INIS)

    Gurel, Kamil; Karabay, Oguz; Gurel, Safiye; Hildebolt, Charles

    2008-01-01

    Purpose. The purpose of this study was to determine the extent to which the use of nonsterile gel, prior to antiseptic procedures in ultrasonography (US)-guided percutaneous biopsies, results in contamination of the biopsy site. Materials and Methods. Patients referred for US-guided percutaneous biopsies were included in this study. Transmission material used for US evaluation before biopsy-site antiseptic procedures were performed was either nonsterile gel or sterile saline. Patients were randomly assigned to two groups: nonsterile gel (n = 30) and sterile saline (n = 30). Before the transmission material was used and after antiseptic procedures were performed, microbial swabs of a 10-cm 2 -diameter area were obtained at the biopsy site. Swabs were also obtained from the gel, saline, and povidine-iodine. Inoculated specimen plates were incubated at 37 o C under aerobic conditions, and the numbers of colony-forming units recorded. Nominal logistic regression analysis was used to calculate the odds of postantisepsis bacterial growth (after antiseptic procedures were performed) based on group, gender, coincidental disease (diabetes, chronic renal failure, and malignancy), biopsy-site location (head and neck or breast and abdomen), and local factors (skin fold, skin tag, and hair). Results. The following odds ratios (adjusted for the other variables) and their 95% confidence intervals were calculated: (1) group (2.9 [0.8-11.1]; p = 0.10); (2) gender (1.2 [0.3-5.2]; p = 0.78); (3) coincidental disease (7.6 [0.9-166.7]; p = 0.09); (4) biopsy site location (6.2 [1.4-31.3]; p = 0.02); and (5) local factors (7.0 [1.6-36.0]; p = 0.01). No bacterial growth occurred with swabs obtained from gel, povidine-iodine, or saline. Conclusion. We conclude that nonsterile gel used prior to percutaneous biopsy does not affect biopsy-site asepsis

  17. THE PROGNOSTIC AND DIAGNOSTIC VALUE OF REPEATED TRANSRECTAL PROSTATE SATURATION BIOPSY

    Directory of Open Access Journals (Sweden)

    M. A. Kurdzhiev

    2014-08-01

    Full Text Available Objective: to determine the rate of prostate cancer (PC development after repeated transrectal saturation prostate biopsy (RTRSPB, to study the characteristics of diagnosed tumors, and to estimate their clinical significance from the data of radical retropubic prostatectomy (RRP.Materials and methods. The results of RTRSPB were analyzed in 226 patients with a later evaluation of a tumor from the results of RRP. All the patients underwent at least 2 prostate biopsies (mean 2.4. The average number of biopsy cores was 26.7 (range 24—30. The average value of total prostate-specific antigen before saturation biopsy was 7.5 (range 7.5 to 28.6 ng/ml. The mean age of patients was 62 years (range 53 to 70.  Results. PC was diagnosed in 14.6% of cases (33/226. An isolated lesion of the prostatic transition zone was in 12.1% of cases. If this zone had been excluded from the biopsy scheme, the detection rate of PC during saturation biopsy should be reduced by 13.8%. Better PC detectability during repeated saturation biopsy generally occurred due to the localized forms of the disease (93.3%. The agreement of Gleason tumor grading in the biopsy and prostatectomy specimens was noted in 66.7% of cases.Conclusion. Saturation biopsy allows prediction of a pathological stage of PC, Gleason grade of a tumor and its site localization with a greater probability. Most tumors detectable by saturation biopsy were clinically significant, which makes it possible to recommend RTRSPB to some cohort of high PC-risk patients 

  18. Relationship between histopathological changes in post partum renal biopsies and renal function tests of African women with early onset pre-eclampsia.

    Science.gov (United States)

    Khedun, S M; Naicker, T; Moodley, J

    2000-05-01

    To improve the diagnostic accuracy of concurrent renal disease in hypertension of pregnancy, biopsy evaluation is essential. In addition, establishing underlying renal disease is important for prognosis on future pregnancies. We therefore designed a study to determine the diagnostic yield of postpartum renal biopsy and the nature and frequency of complications associated with this procedure. Also, to determine relationships, if any, between renal function tests and ultrastructural and histopathological findings. Fifty renal biopsies were performed in the immediate postpartum period in black African women with early onset pre-eclampsia. Each biopsy specimen was placed in a separate container and coded so that sampling was unknown to the electron microscopist. Each biopsy specimen was divided into three parts, and processed and stained for light, fluorescent and transmission electron microscopy using conventional techniques. Renal tissue biopsies were adequate for diagnostic purposes in all cases. There were no complications in any of the 50 patients studied. Ultrastructural examination confirmed the light microscopy findings. In addition the ultrastructural findings showed intramembranous deposits, foot process fusion and mesangial deposits. In 16 patients with normal renal function tests; the biopsies evaluation from these patients showed ultrastructural changes. In the remaining 34 patients with abnormal renal function tests of varying severity; biopsy evaluation from these patients showed both ultrastructural and histopathological changes. Renal biopsy procedure is safe, and ultrastructural and histological findings obtained from postpartum renal biopsies are more informative than the routine renal function tests.

  19. A quantitative swab is a good non-invasive alternative to a quantitative biopsy for quantifying bacterial load in wounds healing by second intention in horses.

    Science.gov (United States)

    Van Hecke, L L; Hermans, K; Haspeslagh, M; Chiers, K; Pint, E; Boyen, F; Martens, A M

    2017-07-01

    The aim of this study was to evaluate different techniques for diagnosing wound infection in wounds healing by second intention in horses and to assess the effect of a vortex and sonication protocol on quantitative bacteriology in specimens with a histologically confirmed biofilm. In 50 wounds healing by second intention, a clinical assessment, a quantitative swab, a semi-quantitative swab, and a swab for cytology were compared to a quantitative tissue biopsy (reference standard). Part of the biopsy specimen was examined histologically for evidence of a biofilm. There was a significant, high correlation (Pquantitative swabs and the quantitative biopsies. The semi-quantitative swabs showed a significant, moderate correlation with the quantitative biopsies (Pquantitative swab is an acceptable non-invasive alternative to a quantitative biopsy for quantifying bacterial load in equine wounds healing by second intention. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Digital imaging improves upright stereotactic core biopsy of mammographic microcalcifications

    International Nuclear Information System (INIS)

    Whitlock, J.P.L.; Evans, A.J.; Burrell, H.C.; Pinder, S.E.; Ellis, I.O.; Blamey, R.W.; Wilson, A.R.M.

    2000-01-01

    AIM: This comparative study was carried out to assess the effect of using digital images compared to conventional film-screen mammography on the accuracy of core biopsy of microcalcifications using upright stereotactic equipment. MATERIALS AND METHODS: The biopsy results from a consecutive series of 104 upright stereotactic 14-gauge core biopsies performed with conventional X-ray (Group A) were compared with 40 biopsies carried out using stereotaxis with digital imaging (Group B). In all cases specimen radiography was performed and analysed for the presence of calcifications. Pathological correlation was then carried out with needle and surgical histology. RESULTS: The use of digital add-on equipment increased the radiographic calcification retrieval rate from 55 to 85% (P < 0.005). The absolute sensitivity of core biopsy in pure ductal carcinoma in situ (DCIS) cases rose from 34 to 69% (P < 0.03), with the complete sensitivity increasing from 52 to 94% (P < 0.005). For DCIS with or without an invasive component the absolute sensitivity rose from 41 to 67% (P = 0.052), while the complete sensitivity was 59% before and 86% after the introduction of digital imaging (P < 0.04). CONCLUSION: Digital equipment improves the performance of upright stereotactic core biopsy of microcalcifications, giving a significantly increased success rate in accurately obtaining calcifications. This leads to an improvement in absolute and complete sensitivity of core biopsy when diagnosing DCIS. Whitlock, J.P.L. (2000)

  1. Biopsy in Musculoskeletal Tumors

    Directory of Open Access Journals (Sweden)

    Mohammad Gharehdaghi

    2014-09-01

    proximity to the skin incision, because this tract is also contaminated and must be excised with the surgical specimen. Imaging-guided core needle biopsy is a well-established technique for the diagnosis of bone and soft tissue tumors and tumor-like lesions in specialized orthopedic oncology centers. Although large lesions of the limbs can easily be biopsied without image guidance, lesions in the spine, para spinal area, and pelvis are difficult to target, therefore taking the advantage of C.T. guidance will improve the accuracy of targeting the lesion for biopsy purposes. We can benefit from image intensifiers for targeting limb lesions rather than C.T. guidance. Also sonographic guide can be applied for soft tissue lesions (Figure D, E, F. In soft tissue tumors, the results of percutaneous CNB are relatively inferior compared to open biopsy whereas almost equal results are expected for bony tumors except for low-grade chondrosarcoma. CNB is a safe, minimally invasive, and cost effective technique for the diagnosis of bone lesions if done by an experienced orthopedic oncologic surgeon and be evaluated by an experienced anatomical bone pathologist (1, 3. For soft tissue tumors, CNB results depend on the size of the lesion, its location and amount of tumor necrosis. Guided needle biopsy have become the standard technique in most orthopedic oncologic centers. The accuracy of this method in our center is more than 90% for bone tumors. Cores should be taken in different directions including areas of central necrotic tissues but from a single well planned entrance. The procedure is quick, especially for bone CNB or soft tissue FNA and CNB, and the diagnosis can be achieved within 24 – 48 hours. The material should be sufficient for immunohistochemistry evaluations as well (1-3. Because I have seen 3 cases of tumor implantation at the towel clips puncture site including 2 chondrosarcomas and a case of malignant schowanoma, so I highly suggest that never crush the skin by towel

  2. A Comparison of Transjugular and Plugged-Percutaneous Liver Biopsy in Patients with Contraindications to Ordinary Percutaneous Liver Biopsy and an 'In-House' Protocol for Selecting the Procedure of Choice

    International Nuclear Information System (INIS)

    Atar, Eli; Ben Ari, Ziv; Bachar, Gil N.; Amlinski, Yelena; Neyman, Chaim; Knizhnik, Michael; Litvin, Sergey; Schmilovitz-Weiss, Hemda; Shapiro, Riki; Bruckhaimer, Elchanan; Tur-Kaspa, Ran; Belenky, Alexander

    2010-01-01

    The purpose of this study was to evaluate the effectiveness and safety of transjugular liver biopsy (TJLB) and plugged-percutaneous liver biopsy (PB) in consecutive patients with severe liver disease associated with impaired coagulation, ascites, or both and to verify the in-house protocol used to select the appropriate procedure. In 2000-2006, 329 patients (208 male [62.8%] and 121 female [37.2%]), aged 1 month to 81 years (mean, 46.8 years), underwent 150 TJLBs (39.1%) or 233 PBs (60.9%) procedures at a major tertiary center, as determined by an in-house protocol. The groups were compared for specimen characteristics, technical success, and complications. Technical success rates were 97.4% for TJLB (146/150) and 99.1% for PB (231/233). TJLB was associated with a lower average core length (1.29 vs. 1.43 cm) and lower average number of specimens obtained (2.44 vs. 2.8), but both methods yielded sufficient tissue for a definitive diagnosis. There were no major complications in either group. TJLB and PB can be safely and effectively performed for the diagnosis of hepatic disease in patients with contraindications for standard percutaneous liver biopsy. When both are technically available, we suggest PB as the procedure of choice, especially in transplanted livers.

  3. A comparison of transjugular and plugged-percutaneous liver biopsy in patients with contraindications to ordinary percutaneous liver biopsy and an "in-house" protocol for selecting the procedure of choice.

    Science.gov (United States)

    Atar, Eli; Ben Ari, Ziv; Bachar, Gil N; Amlinski, Yelena; Neyman, Chaim; Knizhnik, Michael; Litvin, Sergey; Schmilovitz-Weiss, Hemda; Shapiro, Riki; Bruckhaimer, Elchanan; Tur-Kaspa, Ran; Belenky, Alexander

    2010-06-01

    The purpose of this study was to evaluate the effectiveness and safety of transjugular liver biopsy (TJLB) and plugged-percutaneous liver biopsy (PB) in consecutive patients with severe liver disease associated with impaired coagulation, ascites, or both and to verify the in-house protocol used to select the appropriate procedure. In 2000-2006, 329 patients (208 male [62.8%] and 121 female [37.2%]), aged 1 month to 81 years (mean, 46.8 years), underwent 150 TJLBs (39.1%) or 233 PBs (60.9%) procedures at a major tertiary center, as determined by an in-house protocol. The groups were compared for specimen characteristics, technical success, and complications. Technical success rates were 97.4% for TJLB (146/150) and 99.1% for PB (231/233). TJLB was associated with a lower average core length (1.29 vs. 1.43 cm) and lower average number of specimens obtained (2.44 vs. 2.8), but both methods yielded sufficient tissue for a definitive diagnosis. There were no major complications in either group. TJLB and PB can be safely and effectively performed for the diagnosis of hepatic disease in patients with contraindications for standard percutaneous liver biopsy. When both are technically available, we suggest PB as the procedure of choice, especially in transplanted livers.

  4. Tissue Biopsies in Diabetes Research

    DEFF Research Database (Denmark)

    Højlund, Kurt; Gaster, Michael; Beck-Nielsen, Henning

    2007-01-01

    resistance of glucose disposal and glycogen synthesis in this tissue are hallmark features of type 2 diabetes in humans (2,3). During the past two decades, we have carried out more than 1200 needle biopsies of skeletal muscle to study the cellular mechanisms underlying insulin resistance in type 2 diabetes....... Together with morphological studies, measurement of energy stores and metabolites, enzyme activity and phosphorylation, gene and protein expression in skeletal muscle biopsies have revealed a variety of cellular abnormalities in patients with type 2 diabetes and prediabetes. The possibility to establish...... and gene expression profiling on skeletal muscle biopsies have pointed to abnormalities in mitochondrial oxidative phosphorylation in type 2 diabetes. These novel insights will inevitably cause a renewed interest in studying skeletal muscle. This chapter reviews our experience to date and gives a thorough...

  5. Techniques for the recovery and identification of Cryptosporidium oocysts from stool specimens.

    Science.gov (United States)

    Garcia, L S; Bruckner, D A; Brewer, T C; Shimizu, R Y

    1983-07-01

    Due to increasing numbers of patients with documented infections with Cryptosporidium and other coccidia, it is important for the physician and clinical laboratory to be aware of the appropriate diagnostic techniques necessary for organism recovery and identification. Although Cryptosporidium is found in the gastrointestinal tract, tissue biopsies may be insufficient for organism recovery; the examination of stool specimens is a noninvasive procedure and will provide better overall opportunities for organism recovery. Human clinical specimens were examined from 45 patients with confirmed cryptosporidiosis or suspected of having the infection. Tissue biopsy sections, fecal wet preparations, and permanent stained smears were examined. Stool specimens were submitted in 10% Formalin, 2.5% potassium dichromate, and polyvinyl alcohol and were examined for oocysts by using 15 different methods: phase-contrast and light microscopy; Sheather's sugar flotation; Formalin concentration techniques; 10% potassium hydroxide; Giemsa; trichrome; periodic acid-Schiff; modified periodic acid-Schiff; silver methenamine; acridine orange; auramine-rhodamine; Kinyoun acid-fast; Ziehl-Neelsen carbolfuchsin; and a modified acid-fast procedure. Each technique or combination of techniques was assessed by organism quantitation, organism morphology, and ease of visual recognition. Based on these comparative studies, the modified Ziehl-Neelsen carbolfuchsin stain on 10% Formalin-preserved stool is recommended for the recovery and identification of Cryptosporidium.

  6. Accuracy and complications of CT-guided core needle biopsy of peripheral nerve sheath tumours

    Energy Technology Data Exchange (ETDEWEB)

    Pianta, Marcus; Chock, Eric; Schlicht, Stephen [St Vincent' s Hospital, Fitzroy, VIC (Australia); McCombe, David [St Vincent' s Hospital and Victorian Hand Surgery Associates, Victoria (Australia)

    2015-09-15

    This single-centre study retrospectively reviews the complications in patients that have occurred following peripheral nerve sheath tumour biopsy, and assesses whether there is an association with biopsy technique or underlying lesion characteristics. 41 consecutive core needle biopsies of proven peripheral nerve sheath tumours over a 2-year period in a tertiary teaching hospital were reviewed. Patient demographics and symptoms, tumour characteristics and radiological appearances were recorded. Biopsy and surgical histology were correlated, and post-biopsy and surgical complications analyzed. 41 biopsies were performed in 38 patients. 68 % schwannomas, 24 % neurofibromas and 7 % malignant peripheral nerve sheath tumours. Biopsy histology correlated with surgery in all cases. 71 % of lesions were surgically excised. 60 % of patients reported pain related to their lesion. Following the biopsy, 12 % reported increased pain, which resolved in all cases. Pain exacerbation was noted in tumours smaller in size, more superficial and in closer proximity of the biopsy needle tip to the traversing nerve. Number of biopsy needle passes was not associated with an increased incidence of procedure-related pain. Core biopsy of a suspected peripheral nerve sheath tumour may be performed safely before excisional surgery to confirm lesion histology and assist prognosis. There is excellent correlation between core biopsy and excised surgical specimen histology. The most common complication of pain exacerbation is seen in a minority and is temporary, and more likely with smaller, more superficial lesions and a closer needle-tip to traversing nerve distance during biopsy. (orig.)

  7. Accuracy and complications of CT-guided core needle biopsy of peripheral nerve sheath tumours

    International Nuclear Information System (INIS)

    Pianta, Marcus; Chock, Eric; Schlicht, Stephen; McCombe, David

    2015-01-01

    This single-centre study retrospectively reviews the complications in patients that have occurred following peripheral nerve sheath tumour biopsy, and assesses whether there is an association with biopsy technique or underlying lesion characteristics. 41 consecutive core needle biopsies of proven peripheral nerve sheath tumours over a 2-year period in a tertiary teaching hospital were reviewed. Patient demographics and symptoms, tumour characteristics and radiological appearances were recorded. Biopsy and surgical histology were correlated, and post-biopsy and surgical complications analyzed. 41 biopsies were performed in 38 patients. 68 % schwannomas, 24 % neurofibromas and 7 % malignant peripheral nerve sheath tumours. Biopsy histology correlated with surgery in all cases. 71 % of lesions were surgically excised. 60 % of patients reported pain related to their lesion. Following the biopsy, 12 % reported increased pain, which resolved in all cases. Pain exacerbation was noted in tumours smaller in size, more superficial and in closer proximity of the biopsy needle tip to the traversing nerve. Number of biopsy needle passes was not associated with an increased incidence of procedure-related pain. Core biopsy of a suspected peripheral nerve sheath tumour may be performed safely before excisional surgery to confirm lesion histology and assist prognosis. There is excellent correlation between core biopsy and excised surgical specimen histology. The most common complication of pain exacerbation is seen in a minority and is temporary, and more likely with smaller, more superficial lesions and a closer needle-tip to traversing nerve distance during biopsy. (orig.)

  8. Ultrastructural examination of skin biopsies may assist in diagnosing mitochondrial cytopathy when muscle biopsies yield negative results.

    Science.gov (United States)

    McAfee, John L; Warren, Christine B; Prayson, Richard A

    2017-08-01

    Ultrastructural evaluation of skin biopsies has been utilized for diagnosis of mitochondrial disease. This study investigates how frequently skin biopsies reveal mitochondrial abnormalities, correlates skin and muscle biopsy findings, and describes clinical diagnoses rendered following the evaluation. A retrospective review of surgical pathology reports from 1990 to 2015 identified skin biopsies examined by electron microscopy for suspected metabolic disease. A total of 630 biopsies were included from 615 patients. Of these patients, 178 also underwent a muscle biopsy. Of the 630 skin biopsies, 75 (12%) showed ultrastructural abnormalities and 34 (5%) specifically showed mitochondrial abnormalities including increased size (n=27), reduced or abnormal cristae (n=23), dense matrices (n=20), and increased number (n=8). Additional findings included lysosomal abnormalities (n=13), lipid accumulation (n=2) or glycogen accumulation (n=1). Of the 34 patients with mitochondrial abnormalities on skin biopsy, 20 also had muscle biopsies performed and nine showed abnormalities suggestive of a mitochondrial disorder including absent cytochrome oxidase staining (n=2), increased subsarcolemmal NADH, SDH, or cytochrome oxidase staining (n=1), or ultrastructural findings including large mitochondrial size (n=5), abnormal mitochondrial structure (n=5), and increased mitochondrial number (n=4). The most common presenting symptoms were intellectual disability (n=13), seizures (n=12), encephalopathy (n=9), and gastrointestinal disturbances (n=9). At last known follow-up, 12 patients had a definitive diagnosis of a mitochondrial disorder. One patient each had Complex I deficiency, Complex III deficiency, Charcot-Marie-Tooth disease, pyruvate dehydrogenase deficiency, and Phelan-McDermid syndrome. Our results suggest that skin biopsy sometimes yields diagnostic clues suggestive of a mitochondrial cytopathy in cases with a negative muscle biopsy. Copyright © 2017 Elsevier Inc. All rights

  9. Tangential Biopsy Thickness versus Lesion Depth in Longitudinal Melanonychia: A Pilot Study

    Directory of Open Access Journals (Sweden)

    Nilton Di Chiacchio

    2012-01-01

    Full Text Available Longitudinal melanonychia can be caused by melanocyte activation (hypermelanosis or proliferation (lentigo, nevus or melanoma. Histopathologic examination is mandatory for suspicious cases of melanomas. Tangential biopsy of the matrix is an elegant technique avoiding nail plate dystrophy, but it was unknown whether the depth of the sample obtained by this method is adequate for histopathologic diagnosis. Twenty-two patients with longitudinal melanonychia striata were submitted to tangential matrix biopsies described by Haneke. The tissue was stained with hematoxylin-eosin and the specimens were measured at 3 distinct points according to the total thickness: largest (A, intermediate (B and narrowest (C then divided into 4 groups according to the histopathologic diagnosis (G1: hypermelanosis; G2: lentigos; G3: nevus; G4: melanoma. The lesions were measured using the same method. The mean specimen/lesion thickness measure values for each group was: G1: 0,59/0,10 mm, G2: 0,67/0,08 mm, G3: 0,52/0,05 mm, G4: 0,58/0,10 mm. The general average thickness for all the specimens/lesions was 0,59/0,08 mm. We concluded that the tangential excision, for longitudinal melanonychia, provides an adequate material for histopathological diagnosis.

  10. Clinical Value of CT-Guided Needle Biopsy for Retroperitoneal Lesions

    International Nuclear Information System (INIS)

    Tomozawa, Yuki; Inaba, Yoshitaka; Yamaura, Hidekazu; Sato, Yozo; Kato, Mina; Kanamoto, Takaaki; Sakane, Makoto

    2011-01-01

    The purpose of this study was to investigate retrospectively the clinical procedural performance of CT-guided needle biopsy for retroperitoneal lesions. CT-guided needle biopsy was performed in 74 consecutive patients (M:F = 44:30; mean age, 59.7 years) with retroperitoneal lesions between April 1998 and June 2009. The target lesion ranged from 1.5 to 12.5 cm in size. The biopsy access path ranged from 3.5 to 11.5 cm in depth. A biopsy specimen was obtained using an 18-gauge core needle under a CT or CT-fluoroscopy guidance and with the patient under local anesthesia. The histopathological diagnoses from the biopsies were obtained. The diagnostic confirmation of the subtype of lymphoma was evaluated. Satisfactory biopsy samples were obtained in 73 (99%) of 74 patients and a pathological diagnosis was made in 70 (95%) of 74 patients. Sixty three lesions were malignant (45 lymphomas, nine primary tumors, nine lymph node metastases) and seven were benign. The subtype of lymphoma was specified in 43 (96%) of 45 patients who were diagnosed with lymphoma. Analysis of the value of CT-guided biopsy in this series indicated 63 true positives, zero false positive, six true negatives and five false negatives. This test had a sensitivity of 93%, a specificity of 100% and an accuracy of 93%. No major complications were seen and minor complications were noted in seven patients (five with local hematomas, two with transient pain at the puncture site). CT-guided needle biopsy for retroperitoneal lesions is highly practical and useful, and particularly for determining the subtypes in patients with lymphoma.

  11. Diagnosis of mediastinal neoplasms using mediastinoscopy and CT-guided needle biopsy supported by gene analysis

    International Nuclear Information System (INIS)

    Chiba, Wataru; Sawai, Satoru; Ishida, Hisao; Hanawa, Takeshi; Matsubara, Yoshito; Ikeda, Sadao; Kinoshita, Moritoshi; Ikei, Nobuhiro.

    1993-01-01

    Of 140 cases of mediastinal neoplasms in our hospital, histological diagnosis was confirmed in 129 cases. We examined the methods of preoperative biopsy with those 129 cases. Biopsy had been performed in 25 cases. Mediastinoscopy was performed in seven cases, needle biopsy in eight cases, lymph node biopsy in eight cases, esophageal biopsy using a gastrofiberscope in one case, transbronchial biopsy using a bronchoscope in one case. The true positive rates of those methods were 100% for both mediastinoscopy and lymph node biopsy, and 75% for needle biopsy. Preoperative misdiagnosis occurred in two cases of needle biopsy. The postoperative histological diagnosis was malignant lymphoma in both cases. We performed gene analysis of the immunoglobulin heavy chain gene, light chain κ and λ genes, and the T-cell receptor β gene by use of biopsied specimens, and we found rearrangement bands of these genes in the cases of malignant lymphoma. Therefore, we summarize that gene analysis is a reliable method if malignant lymphoma is suspected. If a needle biopsy is performed under CT guidance, the needle is sure to puncture the tumor. We concluded, therefore, that if a tumor is located in the anterior mediastinum, CT-guided needle biopsy should be performed first of all. Mediastinoscopy is a useful method if the tumor is located in the mid-mediastinum. (author)

  12. MR imaging-guided vacuum-assisted breast biopsy: Reduction of false-negative biopsies by short-term control MRI 24–48 h after biopsy

    International Nuclear Information System (INIS)

    Bahrs, S.D.; Hattermann, V.; Preibsch, H.; Hahn, M.; Staebler, A.; Claussen, C.D.; Siegmann-Luz, K.C.

    2014-01-01

    Aim: To evaluate whether another contrast-enhanced (CE) magnetic resonance imaging (MRI) examination 24–48 h after MRI-guided vacuum-assisted breast biopsy (MRI-VAB) can reduce the rate of false-negative cases. Materials and methods: The study included 252 patients who underwent MRI-VAB for the clarification of 299 lesions. The success of MRI-VAB was assessed at interventional MRI and another CE MRI 24–48 h after the intervention. In cases of successful MRI-VAB (complete or partial lesion removal) and benign histological results, follow-up breast MRI was performed. In cases of unsuccessful biopsy (unchanged lesion), tissue sampling was repeated. False-negative cases were calculated to assess the diagnostic value of MRI follow-up within 2 days after intervention. Results: Ninety-eight malignant (32.8%) and 201 (67.2%) benign lesions were diagnosed using MRI-VAB. At immediate unenhanced control MRI, all lesions were assessed as successfully biopsied. In 18 benign cases (6%), CE MRI after 24–48 h showed an unsuccessful intervention. Further tissue sampling revealed another 13 cancers in these patients. This results in a false-negative rate of 11.7%. Follow-up MRI of the benign lesions presented no further malignancy. Conclusions: MRI-VAB with immediate unenhanced control offers a success rate of 94%. The rate of false-negative biopsies (11.7%) could be reduced to zero by using short-term follow-up MRI. Therefore, a further CE breast MRI 24–48 h after benign MRI-VAB to eliminate missed cancers is recommended. - Highlights: • Some suspicious breast lesions are only seen on MRI. • They can be biopsied by a MRI-guided vacuum-assisted biopsy system. • Inadequate sampling causes some false-negative biopsies. • We evaluate an additional control MRI 24 to 48 hours after biopsy. • A reduced rate of the false-negative biopsies was found

  13. Biopsy histopathology in herpes simplex encephalitis and in encephalitis of undefined etiology.

    Science.gov (United States)

    Booss, J.; Kim, J. H.

    1984-01-01

    The histopathology of herpes simplex encephalitis (HSE) has been described principally from postmortem studies which reveal end-stage disease. Biopsy material, which selects an earlier stage in disease development, has been used principally to isolate virus, identify viral particles, and locate viral antigens. Further, little attention has been paid to the histopathology of biopsies of encephalitis of undefined etiology. In the present study, sections from biopsies which yielded virus and those which were negative for virus were evaluated in a systematic and controlled manner. Biopsies yielding virus were characterized by meningeal inflammation, perivascular infiltrates, and glial nodules. Biopsies which did not yield virus and which failed to reveal another diagnosis were characterized by nonspecific gliosis. Thus the early histiopathology of HSE is characterized by early signs of inflammation in the absence of necrosis and generally differs from biopsies in which virus is not isolated. PMID:6098083

  14. Emergency surgery for lung cancer with abscess formation after transbronchial biopsy.

    Science.gov (United States)

    Takanashi, Yusuke; Miyashita, Koichi; Tajima, Shogo; Hayakawa, Takamitsu; Neyatani, Hiroshi; Funai, Kazuhito

    2017-03-01

    Abscess formation in lung cancer after transbronchial biopsy (TBB) is a rare complication with no standard consensus on a coping strategy or prophylaxis. We describe an instructive case of lung cancer which developed into an abscess after TBB. An 80-year-old man with poorly controlled diabetes mellitus underwent TBB for diagnosing a mass lesion in the left upper lobe. The TBB specimen confirmed a diagnosis of lung cancer, and he was scheduled for radical surgery. However, the tumour was revealed to have progressed into an enlarged abscess 24 days after TBB. Prompt use of meropenem failed to relieve the infection, hence we performed emergency left upper lobectomy. Poorly controlled diabetes mellitus was considered to be a risk for the formation of a tumour abscess after TBB. It was difficult to control the infection with conservative treatment using antibiotics; emergency surgical resection was considered to be the safest strategy for recovery.

  15. Small airways dysfunction and neutrophilic inflammation in bronchial biopsies and BAL in COPD

    NARCIS (Netherlands)

    Lapperre, Thérèse S.; Willems, Luuk N. A.; Timens, Wim; Rabe, Klaus F.; Hiemstra, Pieter S.; Postma, Dirkje S.; Sterk, Peter J.

    2007-01-01

    BACKGROUND: The single-breath N(2) test (sbN(2)-test) is closely related to small airways pathology in resected lung specimens of smokers. We investigated whether uneven ventilation and airway closure are associated with specific markers of airway inflammation as obtained by bronchial biopsies, BAL,

  16. Small airways dysfunction and neutrophilic inflammation in bronchial biopsies and BAL in COPD

    NARCIS (Netherlands)

    Lapperre, Therese S.; Willems, Luuk N. A.; Timens, Wim; Rabe, Klaus F.; Hiemstra, Pieter S.; Postma, Dirkje S.; Sterk, Peter J.

    Background: The single-breath N-2 test (sbN(2)-test) is closely related to small airways pathology in resected lung specimens of smokers. We investigated whether uneven ventilation and airway closure are associated with specific markers of airway inflammation as obtained by bronchial biopsies, BAIL,

  17. Percutaneous transluminal biopsy using 7F forceps for diagnosing malignant biliary obstruction

    Energy Technology Data Exchange (ETDEWEB)

    Bahn, Young Eun; Kim, Young Hwan; An, Eun Jung; Kim, See Hyung [Keimyung Univ. College of Medicine, Daegu (Korea, Republic of)

    2012-07-15

    To evaluate the usefulness of the percutaneous transluminal biopsy using 7-F forceps for diagnosing malignant biliary obstruction. One hundred and seven consecutive patients with obstructive jaundice underwent transluminal forceps biopsy. The lesions involved the common bile duct (n = 33), common hepatic duct (n = 13), hilum (n = 17), right or left intrahepatic bile duct (n = 32), multiple sites (extra and intrahepatic ducts, n = 7), or anastomotic sites (n = 5). In each patient, an average of three specimens was taken with 7F biopsy forceps through a transhepatic biliary drainage tract. The final diagnosis was confirmed with pathologic findings, or a clinical and radiologic follow up. The final diagnoses showed malignancies in 75 patients and benign biliary obstructions in 32 patients. Pathologic classifications of malignancies established by forceps biopsy included 67 adenocarcinomas, 1 adenosquamous cell carcinoma, and 1 hepatocelluar carcinoma. There were 6 false-negative diagnoses. The diagnostic performance of transluminal forceps biopsy in malignant biliary obstruction had a sensitivity of 92%, specificity of 100%, positive predictive value of 100%, a negative predictive value of 84.2%, and an accuracy of 94.2%. Percutaneous transluminal forceps biopsy is a safe procedure that is easy to perform through a transhepatic biliary drainage tract. It is a highly accurate technique for diagnosing malignant biliary obstructions.

  18. Systematic Assessment Reveals Lack of Understandability for Prostate Biopsy Online Patient Education Materials.

    Science.gov (United States)

    Maciolek, Kimberly A; Jarrard, David F; Abel, E Jason; Best, Sara L

    2017-11-01

    To evaluate the accuracy, readability, understandability, and actionability of Internet patient education materials (PEM) about transrectal ultrasound-guided prostate biopsy. A comprehensive Internet search was performed to find PEM with pre- or postbiopsy instructions. PEM that were duplicates, government affiliated, international, or video based were excluded. Biopsy instructions were evaluated for accuracy and presence of essential topics. Readability was assessed via word count and Flesch-Kincaid Grade Level. Understandability and actionability were measured using the Patient Education Materials Assessment Tool (PEMAT). Effects of authorship and geographical variation were determined using Fischer exact and Kruskal-Wallis tests. We identified 148 unique PEM. Only 31 (21%) sites adhered to the recommended reading level. Most PEM did not contain recommended graphics (14%), checklists (2%), or summaries (6%). The PEMAT understandability score for academic PEM was higher than private (P = .02) and unaffiliated PEM (P = .01). No websites had inaccurate content. Only 2 PEM sites (1%) included all essential content (stop anticoagulants, antibiotics, need for urinalysis, biopsy pain, when to resume activity, and bleeding complications). Few significant differences based on geographic region were observed for word count, readability, PEMAT scores, or content. Transrectal ultrasound-guided prostate biopsy PEM adhere poorly to guidelines for easy-to-understand materials. Most PEM lack vital information and are written at a reading level that is too complex for patient comprehension. The urology community can construct better websites by consulting PEM advisory materials and providing nontechnical language, figures, and specific instructions. Published by Elsevier Inc.

  19. US-guided percutaneous biopsies with a biopsy gun

    International Nuclear Information System (INIS)

    Ahn, In Oak; Kim, Hyung Jin; Kim, Jae Hyung; Lee, Goo; Jung, Sung Hoon

    1993-01-01

    Core tissue for histologic study is believed by many pathologist to be more diagnostic than material from needle aspiration. Recently introduced automatched biopsy gun simplifies core biopsies with increased quantity and quality of samples. Authors performed 38 percutaneous biopsies from 38 patients with 18G automated biopsy guns under US guide. Diagnostic target tissues were obtained in 33 biopsies(87%), inadequate tissues in 4(11%), and adequate but not of target tissue in 1(3%). There was no major complication requiring treatment, but pain needing analgesics and pain with nausea/vomiting were experienced in 2 and 1 biopsies respectively. Average number of needle passes was 1.5. We concluded that US guided gun biopsy was a easy and safe way to obtain tissue samples of good quantity and quality, especially useful in hospitals without constant availability of specialist in cytopathology

  20. Is it possible to predict low-volume and insignificant prostate cancer by core needle biopsies?

    DEFF Research Database (Denmark)

    Berg, Kasper Drimer; Toft, Birgitte Grønkaer; Røder, Martin Andreas

    2013-01-01

    M: tumour ≤5% of total prostate volume and prostate-specific antigen (PSA) ≤10 ng/mL. In all definitions, Gleason score (GS) was ≤6 and the tumour was organ confined. Biopsies alone performed poorly as a predictor of unifocal and unilateral cancer in the prostatectomy specimens with positive predictive......In an attempt to minimize overtreatment of localized prostate cancer (PCa) active surveillance (AS) and minor invasive procedures have received increased attention. We investigated the accuracy of pre-operative findings in defining insignificant disease and distinguishing between unilateral.......9% and 12.0%, respectively, for identifying InsigM, InsigW and InsigE in the prostate specimen. Conclusively, routine prostate biopsies cannot predict unifocal and unilateral PCa, and must be regarded insufficient to select patients for focal therapy. Although candidates for AS may be identified using...

  1. Evaluation of gastroscopy and biopsy of the proventriculus and ventriculus in pigeons (Columba livia).

    Science.gov (United States)

    Sladakovic, Izidora; Ellis, Angela E; Divers, Stephen J

    2017-01-01

    OBJECTIVE To evaluate the efficacy and safety of gastroscopy and biopsy of the proventriculus and ventriculus in pigeons (Columba livia). ANIMALS 15 adult pigeons. PROCEDURES Each pigeon was anesthetized, and the upper gastrointestinal tract (from the cervical portion of the esophagus to the ventriculus) was endoscopically evaluated by use of a rigid endoscope inserted orally. Saline (0.9% NaCl) solution was orally infused to achieve lumen dilation and visibility. Two mucosal biopsy specimens were collected from each of the proventriculus and ventriculus, histologically evaluated, and graded for crush artifacts and depth. Pigeons were monitored for adverse effects for 3 to 6 days after the procedure, after which they were euthanized for necropsy. RESULTS Gastroscopy via the oral approach provided excellent visibility of the lumen and mucosal surfaces of the proventriculus and cranial portion of the ventriculus and was safe provided that appropriate precautions were taken. Two intraoperative deaths occurred at the beginning of the study; following procedure refinement, no additional deaths occurred. No major adverse effects of the procedure were detected in the remaining 13 pigeons during the postoperative monitoring period or at necropsy. Diagnostic quality of proventriculus specimens was adequate for 10 of 13 pigeons. Eight of 13 ventriculus specimens were of inadequate quality, and only 3 were of adequate quality. CONCLUSIONS AND CLINICAL RELEVANCE Gastroscopy was useful for evaluating the lumen and mucosal surface of the proventriculus and ventriculus in pigeons, and biopsy of those organs was safely performed with the appropriate technique. Further evaluation of these techniques is needed in birds with clinical disease and birds of other species.

  2. Specimen Identification Errors in Breast Biopsies: Age Matters. Report of Two Near-Miss Events and Review of the Literature.

    Science.gov (United States)

    Tozbikian, Gary; Gemignani, Mary L; Brogi, Edi

    2017-09-01

    The consequences of patient identification errors due to specimen mislabeling can be deleterious. We describe two near-miss events involving mislabeled breast specimens from two patients who sought treatment at our institution. In both cases, microscopic review of the slides identified inconsistencies between the histologic findings and patient age, unveiling specimen identification errors. By correlating the clinical information with the microscopic findings, we identified mistakes that had occurred at the time of specimen accessioning at the original laboratories. In both cases, thanks to a timely reassignment of the specimens, the patients suffered no harm. These cases highlight the importance of routine clinical and pathologic correlation as a critical component of quality assurance and patient safety. A review of possible specimen identification errors in the anatomic pathology setting is presented. © 2017 Wiley Periodicals, Inc.

  3. Recommendations for processing cardiovascular surgical pathology specimens: a consensus statement from the Standards and Definitions Committee of the Society for Cardiovascular Pathology and the Association for European Cardiovascular Pathology

    NARCIS (Netherlands)

    Stone, James R.; Basso, Cristina; Baandrup, Ulrik T.; Bruneval, Patrick; Butany, Jagdish; Gallagher, Patrick J.; Halushka, Marc K.; Miller, Dylan V.; Padera, Robert F.; Radio, Stanley J.; Sheppard, Mary N.; Suvarna, Kim; Tan, Carmela D.; Thiene, Gaetano; van der Wal, Allard C.; Veinot, John P.

    2012-01-01

    With the advent of molecular subclassification of diseases, much consideration should be given to the proper processing of cardiovascular surgical pathology specimens to maximize patient care. Such specimens include endomyocardial biopsies, cardiac myectomy specimens, cardiac apical core segments,

  4. Gallium-67 imaging in patients with dilated cardiomyopathy and biopsy-proven myocarditis

    International Nuclear Information System (INIS)

    O'Connell, J.B.; Henkin, R.E.; Robinson, J.A.; Subramanian, R.; Scanlon, P.J.; Gunnar, R.M.

    1984-01-01

    Current standards for detection of myocarditis in a clinical setting rely on endomyocardial biopsy for accurate diagnosis. With this technique a subset of patients with dilated cardiomyopathy show unsuspected myocarditis histologically. Endomyocardial biopsy, despite its specificity, may lack sensitivity due to sampling error if the inflammation is patchy or focal. Therefore, inflammation-sensitive radioisotopic imaging may be a useful adjunct in the diagnosis of myocarditis. This study was designed to evaluate the applicability of gallium-67 (67Ga) myocardial imaging as an adjunct to endomyocardial biopsy in the diagnosis of myocarditis. Sixty-eight consecutive patients referred for evaluation of dilated cardiomyopathy underwent 71 parallel studies with 67Ga imaging and biopsies that served as the basis of comparison for this study. Histologic myocarditis was identified in 8% of biopsy specimens. Clinical and hemodynamic parameters could not be used to predict the presence of myocarditis. Five of six biopsy samples (87%) with myocarditis showed dense 67Ga uptake, whereas only nine of 65 negative biopsy samples (14%) were paired with equivocally positive 67Ga scans. The single patient with myocarditis and no myocardial 67Ga uptake had dense mediastinal lymph node uptake that may have obscured cardiac uptake. The incidence of myocarditis on biopsy with a positive 67Ga scan was 36% (5/14); however, the incidence of myocarditis with a negative 67Ga scan was only 1.8% (1/57). Follow-up scans for three patients showed close correlation of 67Ga uptake with myocarditis on biopsy. In conclusion 67Ga may be a useful screening test for identifying patients with a high yield of myocarditis on biopsy, and serial scans may eliminate the need for frequent biopsies in patients with proven myocarditis

  5. Detection, mapping, and quantification of single walled carbon nanotubes in histological specimens with photoacoustic microscopy.

    NARCIS (Netherlands)

    Avti, P.K.; Hu, S.; Favazza, C.; Mikos, A.G.; Jansen, J.A.; Shroyer, K.R.; Wang, L.V.; Sitharaman, B.

    2012-01-01

    AIMS: In the present study, the efficacy of multi-scale photoacoustic microscopy (PAM) was investigated to detect, map, and quantify trace amounts [nanograms (ng) to micrograms (microg)] of SWCNTs in a variety of histological tissue specimens consisting of cancer and benign tissue biopsies

  6. Significant association between renal function and area of amyloid deposition in kidney biopsy specimens in both AA amyloidosis associated with rheumatoid arthritis and AL amyloidosis.

    Science.gov (United States)

    Kuroda, Takeshi; Tanabe, Naohito; Hasegawa, Eriko; Wakamatsu, Ayako; Nozawa, Yukiko; Sato, Hiroe; Nakatsue, Takeshi; Wada, Yoko; Ito, Yumi; Imai, Naofumi; Ueno, Mitsuhiro; Nakano, Masaaki; Narita, Ichiei

    2017-06-01

    The kidney is a major target organ for systemic amyloidosis, which results in proteinuria and an elevated serum creatinine level. The clinical manifestations and precursor proteins of amyloid A (AA) and light-chain (AL) amyloidosis are different, and the renal damage due to amyloid deposition also seems to differ. The purpose of this study was to clarify haw the difference in clinical features between AA and AL amyloidosis are explained by the difference in the amount and distribution of amyloid deposition in the renal tissues. A total of 119 patients participated: 58 patients with an established diagnosis of AA amyloidosis (AA group) and 61 with AL amyloidosis (AL group). We retrospectively investigated the correlation between clinical data, pathological manifestations, and the area occupied by amyloid in renal biopsy specimens. In most of the renal specimens the percentage area occupied by amyloid was less than 10%. For statistical analyses, the percentage area of amyloid deposition was transformed to a common logarithmic value (Log 10 %amyloid). The results of sex-, age-, and Log 10 %amyloid-adjusted analyses showed that systolic blood pressure (SBP) was higher in the AA group. In terms of renal function parameters, serum creatinine, creatinine clearance (Ccr) and estimated glomerular filtration rate (eGFR) indicated significant renal impairment in the AA group, whereas urinary protein indicated significant renal impairment in the AL group. Pathological examinations revealed amyloid was predominantly deposited at glomerular basement membrane (GBM) and easily transferred to the mesangial area in the AA group, and it was predominantly deposited at in the AL group. The degree of amyloid deposition in the glomerular capillary was significantly more severe in AL group. The frequency of amyloid deposits in extraglomerular mesangium was not significantly different between the two groups, but in AA group, the degree amyloid deposition was significantly more severe, and

  7. The localisation of treponemes and characterisation of the inflammatory infiltrate in skin biopsies from patients with primary or secondary syphilis, or early infectious yaws

    NARCIS (Netherlands)

    Engelkens, H. J.; ten Kate, F. J.; Judanarso, J.; Vuzevski, V. D.; van Lier, J. B.; Godschalk, J. C.; van der Sluis, J. J.; Stolz, E.

    1993-01-01

    To study the localisation of treponemes and to analyse the inflammatory infiltrate in biopsy specimens from patients with primary or secondary syphilis, or early infectious yaws. Skin biopsies originating from human lesions of primary (29x) or secondary (15x) syphilis (Rotterdam), or early yaws

  8. Histological evidence of testicular dysgenesis in contralateral biopsies from 218 patients with testicular germ cell cancer

    DEFF Research Database (Denmark)

    Hoei-Hansen, Christina E; Holm, Mette; Rajpert-De Meyts, Ewa

    2003-01-01

    dysgenesis, microscopic dysgenetic features were quantified in contralateral testicular biopsies in patients with a testicular germ cell tumour. Two hundred and eighty consecutive contralateral testicular biopsies from Danish patients with testicular cancer diagnosed in 1998-2001 were evaluated...... retrospectively. Two hundred and eighteen specimens were subsequently included in this study, after 63 patients who did not meet inclusion criteria had to be excluded. The presence of carcinoma in situ (which is believed to originate from transformed gonocytes) was detected in 8.7% of biopsies. The incidence...... patients, areas with immature and morphologically distorted tubules were also noted. Spermatogenesis was qualitatively normal in 51.4%, whereas 11.5% had very poor or absent spermatogenesis. It is concluded that microscopic testicular dysgenesis is a frequent feature in contralateral biopsies from patients...

  9. Fifteen years of kidney biopsies in children: A single center in Egypt

    Directory of Open Access Journals (Sweden)

    Ashraf Bakr

    2014-01-01

    Full Text Available This study retrospectively investigates the indications and results of renal biopsy in children to determine the patterns of childhood kidney disease in a single tertiary children′s hospital in Egypt. We included all the patients who underwent ultrasound-guided renal biopsy from 1998 to 2012. All the kidney biopsies were studied under light microscopy, while immunofluorescence and electron microscopy were performed when indicated. A total of 1246 renal biopsies were performed over 15 years, on 1096 patients. The mean age of the patients at the time of biopsy was 9.2 ± 3.7 years. The main indication for a biopsy was the steroid-resistant nephrotic syndrome (n = 354, 28.4%, followed by the atypical nephrotic syndrome (n = 250, 20.1%, and renal abnormalities in the systemic diseases (n = 228, 18.3 %. In the 1226 pathologically diagnosed specimens, primary glomerulonephritis was the most common finding (n = 826, 67.4%, followed by secondary glomerulonephritis (n = 238, 19.4%. The most common causes of primary glomerulonephritis were Minimal Change Disease (MCD (n = 267, 21.8%, diffuse proliferative glomerulonephritis (n = 188, 15. 3%, and focal proliferative glomerulonephritis (n = 164, 13.3%. Lupus nephritis (n = 209, 17% was the most common cause of secondary glomerulonephritis. We conclude that the steroid-resistant nephrotic syndrome was the most frequent indication for biopsy and minimal change disease was the most common histopathological finding in our population.

  10. Novel modified Ussing chamber for the study of absorption and secretion in human endoscopic biopsies

    DEFF Research Database (Denmark)

    Larsen, R; Mertz-Nielsen, A; Hansen, M B

    2001-01-01

    ). Experimental biopsy specimens showed intact surface epithelium by histologic examination and did not differ from controls apart from minor indications of edge damage. No difference in basal electrical parameters and D-glucose fluxes were found between Helicobacter pylori positive and negative patients. Our...

  11. Outcomes following negative prostate biopsy for patients with persistent disease after radiotherapy for prostate cancer

    Directory of Open Access Journals (Sweden)

    Jacob H. Cohen

    2010-02-01

    Full Text Available PURPOSE: When faced with biochemical recurrence after definitive radiotherapy for prostate cancer, clinicians must determine whether the recurrence is local or systemic. Post radiotherapy prostate biopsies to detect persistent local disease are difficult to interpret histopathologically and are subject to sampling error. Our study examines outcomes for patients with a negative prostate biopsy performed for rising prostate-specific antigen (PSA levels after prostate radiation. MATERIALS AND METHODS: We performed a retrospective review of 238 prostate cancer patients with a negative biopsy following definitive radiotherapy. Seventy-five of these patients had biochemical recurrence at the time of biopsy. A negative biopsy was defined as the absence of prostate cancer without radiation-treatment effect in the specimen. RESULTS: Patients underwent biopsy at a mean of 41 months after the completion of radiation. They had a mean PSA of 6. Patients were followed for an average of 63 months. Thirty-two patients (43% developed metastasis, and 11 (15% died of prostate cancer despite a negative post-radiation biopsy. Five of nine patients (56% with sequential biopsies had a positive second biopsy. CONCLUSIONS: Patients with PSA recurrence and a negative post-radiation biopsy have a high chance of persistent local disease, progression, and death from prostate cancer. Furthermore, an initial negative biopsy does not rule-out local recurrence. Patients with biochemical recurrence after radiotherapy for prostate cancer need to be evaluated earlier for local recurrence.

  12. Clonality Analysis of Helicobacter pylori in Patients Isolated from Several Biopsy Specimens and Gastric Juice in a Japanese Urban Population by Random Amplified Polymorphic DNA Fingerprinting

    Directory of Open Access Journals (Sweden)

    Nariaki Toita

    2013-01-01

    Full Text Available Background. The number of Helicobacter pylori clones infecting a single host has been discussed in numerous reports. The number has been suggested to vary depending on the regions in the world. Aim. The purpose of this study was to examine the number of clones infecting a single host in a Japanese urban population. Materials and Methods. Thirty-one Japanese patients undergoing upper gastrointestinal endoscopy were enrolled in this study. H. pylori isolates (total 104 strains were obtained from biopsy specimens (antrum, corpus, and duodenum and gastric juice. Clonal diversity was examined by the random amplified polymorphic DNA (RAPD fingerprinting method. Results. The RAPD fingerprinting patterns of isolates from each patient were identical or very similar. And the isolates obtained from several patients with 5- to 9-year intervals showed identical or very similar RAPD patterns. Conclusion. Each Japanese individual of an urban population is predominantly infected with a single H. pylori clone.

  13. Semi-Nested Real-Time Reverse Transcription Polymerase Chain Reaction Methods for the Successful Quantitation of Cytokeratin mRNA Expression Levels for the Subtyping of Non-Small-Cell Lung Carcinoma Using Paraffin-Embedded and Microdissected Lung Biopsy Specimens

    International Nuclear Information System (INIS)

    Nakanishi, Yoko; Shimizu, Tetsuo; Tsujino, Ichiro; Obana, Yukari; Seki, Toshimi; Fuchinoue, Fumi; Ohni, Sumie; Oinuma, Toshinori; Kusumi, Yoshiaki; Yamada, Tsutomu; Takahashi, Noriaki; Hashimoto, Shu; Nemoto, Norimichi

    2013-01-01

    In patients with inoperable advanced non-small cell lung carcinomas (NSCLCs), histological subtyping using small-mount biopsy specimens was often required to decide the indications for drug treatment. The aim of this study was to assess the utility of highly sensitive mRNA quantitation for the subtyping of advanced NSCLC using small formalin fixing and paraffin embedding (FFPE) biopsy samples. Cytokeratin (CK) 6, CK7, CK14, CK18, and thyroid transcription factor (TTF)-1 mRNA expression levels were measured using semi-nested real-time quantitative (snq) reverse-transcribed polymerase chain reaction (RT-PCR) in microdissected tumor cells collected from 52 lung biopsies. Our results using the present snqRT-PCR method showed an improvement in mRNA quantitation from small FFPE samples, and the mRNA expression level using snqRT-PCR was correlated with the immunohistochemical protein expression level. CK7, CK18, and TTF-1 mRNA were expressed at significantly higher levels (P<0.05) in adenocarcinoma (AD) than in squamous cell carcinoma (SQ), while CK6 and CK14 mRNA expression was significantly higher (P<0.05) in SQ than in AD. Each histology-specific CK, particularly CK18 in AD and CK6 in SQ, were shown to be correlated with a poor prognosis (P=0.02, 0.02, respectively). Our results demonstrated that a quantitative CK subtype mRNA analysis from lung biopsy samples can be useful for predicting the histology subtype and prognosis of advanced NSCLC

  14. Hepatitis E in liver biopsies from patients with acute hepatitis of clinically unexplained origin.

    Directory of Open Access Journals (Sweden)

    Uta eDrebber

    2013-12-01

    Full Text Available Hepatitis E virus (HEV is a small RNA virus and the infectious agent of hepatitis E that occurs worldwide either as epidemics in Asia caused by genotype 1 and 2 or as sporadic disease in industrialized countries induced by genotype 3 and 4. The frequency might be underestimated in central Europe as a cause of acute hepatitis. Therefore, we analyzed on liver biopsies, if cases of acute hepatitis with clinically unknown or obscure diagnosis were actually caused by the infection with HEV.We included 221 liver biopsies retrieved from the files of the institute of pathology during the years 2000 till 2010 that were taken from patients with acute hepatitis of obscure or doubtful diagnosis. From all biopsies RNA was extracted, prepared, and subjected to RT-PCR with specific primers. Amplified RNA was detected in 7 patients, sequenced and the genotype 3 could be determined in four of the seven of positive specimens from 221 samples. Histopathology of the biopsies revealed a classic acute hepatitis with cholestatic features and in some cases confluent necrosis in zone 3. Histology in a cohort of matched patients was less severe and showed more eosinophils. The analysis of the immune response by subtyping of liver infiltrating lymphocytes showed circumstantial evidence of adaptive immune reaction with CD 8 positive CTLs being the dominant lymphocyte population.In conclusion, in doubtful cases of acute hepatitis of unknown origine hepatitis E virus infection should be considered as etiology in central Europe. We demonstrate for the first time that the diagnosis can be made in paraffin-embedded liver biopsies reliably when no serum is available and also the genotype can be determined. The analysis of the immune response by subtyping of liver infiltrating lymphocytes indicates an adaptive mechanism suggesting in analogy with HAV, HBV and HCV that the virus itself is not cytopathic but liver damage is due to immune reaction.

  15. Biópsia mamária realizada pela técnica de biópsia helicoide: estudo experimental Breast biopsy performed by the helicoid biopsy technique: an experimental study

    Directory of Open Access Journals (Sweden)

    Eliel de Souza

    2010-12-01

    Full Text Available OBJETIVO: avaliar o desempenho da biópsia helicoide na realização de biópsias mamárias. MÉTODOS: foi selecionado aleatoriamente uma amostra composta de 30 pacientes portadoras de câncer de mama submetidas à mastectomia. Foram excluídas as mulheres portadoras de tumor que tivessem consistência pétrea, não-palpável, com manipulação cirúrgica prévia ou que contivesse líquido. Utilizando-se o kit de biópsia helicoide e um equipamento de core biopsy com cânula e agulha de 14 gauge, respectivamente, coletou-se um fragmento por equipamento em área sã e nos tumores, em cada peça cirúrgica, totalizando 120 fragmentos para estudo histológico. Para a análise dos dados, definiu-se um nível de confiança de 95% e utilizou-se o software SPSS, versão 13; o índice de concordância Kappa e o teste paramétrico t de Student. RESULTADOS: a média das idades das pacientes foi de 51,6 anos (±11,1 anos. A core biopsy apresentou sensibilidade de 93,3%, especificidade de 100% e acurácia de 96,7%, enquanto a biópsia helicoide teve sensibilidade de 96,7%, especificidade de 100% e acurácia de 98,3%. Na comparação entre a histologia dos tumores e dos fragmentos de biópsias, houve alto grau de concordância nos diagnósticos (Kappa igual a 0,9, com pPURPOSE: to assess the helicoid biopsy performance when carrying out breast biopsies. METHODS: thirty patients with breast cancer submitted to mastectomy were selected at random. Women with a tumor of petreous consistency, nonpalpable, submitted to previous surgical manipulation or containing fluid were excluded. The helicoid biopsy kit and a core biopsy device with a cannula and a 14-gauge-needle, respectively, were used to collect a fragment each from a healthy area and from the tumor of each surgical specimen, for a total of 120 fragments for histological study. Data were analyzed statistically by the parametric Student's t-test and by the Kappa concordance index at the 95% confidence level

  16. Muscle biopsies from human muscle diseases with myopathic pathology reveal common alterations in mitochondrial function.

    Science.gov (United States)

    Sunitha, Balaraju; Gayathri, Narayanappa; Kumar, Manish; Keshava Prasad, Thottethodi Subrahmanya; Nalini, Atchayaram; Padmanabhan, Balasundaram; Srinivas Bharath, Muchukunte Mukunda

    2016-07-01

    Muscle diseases are clinically and genetically heterogeneous and manifest as dystrophic, inflammatory and myopathic pathologies, among others. Our previous study on the cardiotoxin mouse model of myodegeneration and inflammation linked muscle pathology with mitochondrial damage and oxidative stress. In this study, we investigated whether human muscle diseases display mitochondrial changes. Muscle biopsies from muscle disease patients, represented by dysferlinopathy (dysfy) (dystrophic pathology; n = 43), polymyositis (PM) (inflammatory pathology; n = 24), and distal myopathy with rimmed vacuoles (DMRV) (distal myopathy; n = 31) were analyzed. Mitochondrial damage (ragged blue and COX-deficient fibers) was revealed in dysfy, PM, and DMRV cases by enzyme histochemistry (SDH and COX-SDH), electron microscopy (vacuolation and altered cristae) and biochemical assays (significantly increased ADP/ATP ratio). Proteomic analysis of muscle mitochondria from all three muscle diseases by isobaric tag for relative and absolute quantitation labeling and liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis demonstrated down-regulation of electron transport chain (ETC) complex subunits, assembly factors and Krebs cycle enzymes. Interestingly, 80 of the under-expressed proteins were common among the three pathologies. Assay of ETC and Krebs cycle enzyme activities validated the MS data. Mitochondrial proteins from muscle pathologies also displayed higher tryptophan (Trp) oxidation and the same was corroborated in the cardiotoxin model. Molecular modeling predicted Trp oxidation to alter the local structure of mitochondrial proteins. Our data highlight mitochondrial alterations in muscle pathologies, represented by morphological changes, altered mitochondrial proteome and protein oxidation, thereby establishing the role of mitochondrial damage in human muscle diseases. We investigated whether human muscle diseases display mitochondrial changes. Muscle biopsies

  17. Cold knife cone biopsy

    Science.gov (United States)

    ... biopsy; Pap smear - cone biopsy; HPV - cone biopsy; Human papilloma virus - cone biopsy; Cervix - cone biopsy; Colposcopy - cone biopsy Images Female reproductive anatomy Cold cone biopsy Cold cone removal References Baggish ...

  18. Dermatofibrosarcoma protuberans diagnosed by a single biopsy

    Directory of Open Access Journals (Sweden)

    Kristian Bakke Arvesen

    2012-07-01

    Full Text Available This brief report is about a 9 year old girl presenting with a 2.5 cm circular blue to violet discoloration on the anterolateral upper left thigh. The first biopsy taken revealed the diagnosis dermatofibrosarcoma protuberans. The patient underwent surgery at a specialized sarcoma center with post operative histology showing free wide resection margin. Preoperative chest x-ray showed no sign of metastasis. This brief report emphasizes the significance of the use of biopsy when cutaneous elements look suspicious and diagnosis is unclear.

  19. Sentinel lymph node biopsy in oral cancer

    DEFF Research Database (Denmark)

    Thomsen, Jørn Bo; Sørensen, Jens Ahm; Grupe, Peter

    2005-01-01

    PURPOSE: To validate lymphatic mapping combined with sentinel lymph node biopsy as a staging procedure, and to evaluate the possible clinical implications of added oblique lymphoscintigraphy and/or tomography and test the intra- and interobserver reproducibility of lymphoscintigraphy. MATERIAL......: Eleven (28%) patients were upstaged. The sentinel lymph node identification rate was 97.5%. Sentinel lymph node biopsy significantly differentiated between patients with or without lymph node metastasis (P = 0.001). Lymphatic mapping revealed 124 hotspots and 144 hot lymph nodes were removed by sentinel...

  20. Liver biopsy

    Science.gov (United States)

    Biopsy - liver; Percutaneous biopsy ... the biopsy needle to be inserted into the liver. This is often done by using ultrasound. The ... the chance of damage to the lung or liver. The needle is removed quickly. Pressure will be ...

  1. Effectiveness of core biopsy for screen-detected breast lesions under 10 mm: implications for surgical management.

    Science.gov (United States)

    Farshid, Gelareh; Downey, Peter; Pieterse, Steve; Gill, P Grantley

    2017-09-01

    Technical advances have improved the detection of small mammographic lesions. In the context of mammographic screening, accurate sampling of these lesions by percutaneous biopsy is crucial in limiting diagnostic surgical biopsies, many of which show benign results. Women undergoing core biopsy between January 1997 and December 2007 for core histology, 345 women (43.0%) were immediately cleared of malignancy and 300 (37.4%) were referred for definitive cancer treatment. A further 157 women (19.6%) required diagnostic surgical biopsy because of indefinite or inadequate core results or radiological-pathological discordance, and one woman (0.1%) needed further imaging in 12 months. The open biopsies were malignant in 46 (29.3%) cases. The positive predictive value of malignant core biopsy was 100%. The negative predictive value for benign core results was 97.7%, and the false-negative rate was 2.6%. The lesion could not be visualized after core biopsy in 5.1% of women and in 4.0% of women with malignant core biopsies excision specimens did not contain residual malignancy. Excessive delays in surgery because of complications of core biopsy were not reported. Even at this small size range, core biopsy evaluation of screen-detected breast lesions is highly effective and accurate. A lesion miss rate of 3.1% and under-representation of lesions on core samples highlight the continued need for multidisciplinary collaboration and selective use of diagnostic surgical biopsy. © 2015 Royal Australasian College of Surgeons.

  2. Detection of Xenotropic Murine Leukemia Virus-Related Virus in Prostate Biopsy Samples

    International Nuclear Information System (INIS)

    Baig, F. A.; Mirza, T.; Khanani, R.; Khan, S.

    2014-01-01

    Objective: To determine the association of Xenotropic murine leukemia virus related virus (XMRV) infection with prostate cancer and compare it with benign prostate hyperplasia. Study Design: Case control study. Place and Duration of Study: Department of Histopathology and Molecular Pathology, Dow University of Health Sciences, Karachi, from January 2009 to December 2012. Methodology: XMRV was screened in 50 prostate cancer and 50 benign prostatic hyperplasia biopsies using conventional end-point PCR. Other studied variables were family history of prostate cancer, patients age and Gleason score. Results: XMRV was detected in 4 (8%) of the 50 prostate cancer biopsy specimens compared to none in biopsies with benign prostatic hyperplasia. However, there was no significant statistical association of XMRV infection with the other variables. Conclusion: A low frequency of XMRV infection was found in this case-control study. Men, who harbor XMRV infection, may be at increased risk of prostate cancer but this needs to be investigated further at a larger scale. (author)

  3. Profiling cellular bioenergetics, glutathione levels, and caspase activities in stomach biopsies of patients with upper gastrointestinal symptoms

    Science.gov (United States)

    Alfazari, Ali S; Al-Dabbagh, Bayan; Al-Dhaheri, Wafa; Taha, Mazen S; Chebli, Ahmad A; Fontagnier, Eva M; Koutoubi, Zaher; Kochiyi, Jose; Karam, Sherif M; Souid, Abdul-Kader

    2015-01-01

    AIM: To measure biochemical parameters in stomach biopsies and test their suitability as diagnostic biomarkers for gastritis and precancerous lesions. METHODS: Biopsies were obtained from the stomachs of two groups of patients (n = 40) undergoing fiber-optic endoscopy due to upper gastrointestinal symptoms. In the first group (n = 17), only the corpus region was examined. Biopsies were processed for microscopic examination and measurement of mitochondrial O2 consumption (cellular respiration), cellular adenosine triphosphate (ATP), glutathione (GSH), and caspase activity. In the second group of patients (n = 23), both corpus and antral regions were studied. Some biopsies were processed for microscopic examination, while the others were used for measurements of cellular respiration and GSH level. RESULTS: Microscopic examinations of gastric corpus biopsies from 17 patients revealed normal mucosae in 8 patients, superficial gastritis in 7 patients, and chronic atrophic gastritis in 1 patient. In patients with normal histology, the rate (mean ± SD) of cellular respiration was 0.17 ± 0.02 μmol/L O2 min-1 mg-1, ATP content was 487 ± 493 pmol/mg, and GSH was 469 ± 98 pmol/mg. Caspase activity was detected in 3 out of 8 specimens. The values of ATP and caspase activity were highly variable. The presence of superficial gastritis had insignificant effects on the measured biomarkers. In the patient with atrophic gastritis, cellular respiration was high and ATP was relatively low, suggesting uncoupling oxidative phosphorylation. In the second cohort of patients, the examined biopsies showed either normal or superficial gastritis. The rate of cellular respiration (O2. μmol/L min-1 mg-1) was slightly higher in the corpus than the antrum (0.18 ± 0.05 vs 0.15 ± 0.04, P = 0.019). The value of GSH was about the same in both tissues (310 ± 135 vs 322 ± 155, P = 0.692). CONCLUSION: The corpus mucosa was metabolically more active than the antrum tissue. The data in this

  4. Computed tomography-guided percutaneous biopsy of bone lesions: rate of diagnostic success and complications

    International Nuclear Information System (INIS)

    Maciel, Macello Jose Sampaio; Tyng, Chiang Jeng; Barbosa, Paula Nicole Vieira Pinto; Bitencourt, Almir Galvao Vieira; Matushita Junior, Joao Paulo Kawaoka; Zurstrassen, Charles Edouard; Chung, Wu Tu; Chojniak, Rubens

    2014-01-01

    Objective: To determine the rates of diagnostic success and complications of computed tomography (CT)-guided percutaneous biopsy of bone lesions suspected for malignancy. Materials and Methods: Retrospective study including 186 cases of CT-guided percutaneous biopsies of bone lesions in the period from January, 2010 to December, 2012. All the specimens were obtained with 8-10 gauge needles. The following data were collected: demographics, previous history of malignancy, data related to the lesion, to the procedure, and to histological results. Results: Most patients were women (57%), and the mean age was 53.0 ± 16.4 years. In 139 cases (74.6%), there was diagnostic suspicion of metastasis and the most common primary tumors were breast (32.1%) and prostate (11.8%). The bones most commonly involved were spine (36.0%), hip (32.8%) and long bones (18.3%). Complications occurred in only three cases (1.6%) including bone fracture, paraesthesia with functional impairment, and needle breakage requiring surgical removal. The specimens collected from 183 lesions (98.4%) were considered appropriate for diagnosis. Malignant results were more frequently found in patients who had a suspected secondary lesion and history of known malignancy (p < 0.001), and in patients who underwent PET/CT-guided procedures (p = 0.011). Conclusion: CT-guided percutaneous biopsy is a safe and effective procedure for the diagnosis of suspicious bone lesions. (author)

  5. Biopsy diagnoses of clinically atypical pigmented lesions of the head and neck in adults.

    Science.gov (United States)

    Udovenko, Olga; Griffin, John R; Elston, Dirk M

    2014-10-01

    A subset of facial melanoma in situ has histological features that overlap with those of "dysplastic" nevi. The authors evaluated this important diagnostic pitfall by assessing the frequency of melanoma as the final diagnosis in skin biopsies submitted over a 1-year period with a clinical impression of "atypical" or dysplastic nevus from the head or neck of adults. A total of 1998 biopsies met inclusion criteria. Final diagnoses included both melanocytic and nonmelanocytic processes. Clear trends were noted based on the age of the patient with benign nevi encompassing nearly 70% of specimens in patients aged 21-29 years and jawline; and 3, temple), a location not traditionally associated with atypical nevi. Facial atypical nevi were found in all age groups. Malignant melanoma accounted for 1.8% of all specimens increasing from 0% in the patients aged 21-29 years to 5% in patients aged 70 years and above. Caution is warranted when evaluating skin biopsies from sun-damaged skin of the head or neck of an older adult submitted with a clinical diagnosis of atypical nevus. However, the authors' findings suggest that atypical nevi with histological features of dysplastic nevi occur on the head and neck of adults, including elderly adults. The incidence of such lesions decreases with age as the incidence of melanoma increases, and careful clinicopathologic correlation is vital.

  6. Computed tomography-guided percutaneous biopsy of bone lesions: rate of diagnostic success and complications

    Energy Technology Data Exchange (ETDEWEB)

    Maciel, Macello Jose Sampaio; Tyng, Chiang Jeng; Barbosa, Paula Nicole Vieira Pinto; Bitencourt, Almir Galvao Vieira; Matushita Junior, Joao Paulo Kawaoka; Zurstrassen, Charles Edouard; Chung, Wu Tu; Chojniak, Rubens, E-mail: macellomaciel@me.com [A.C.Camargo Cancer Center, Sao Paulo, SP (Brazil)

    2014-09-15

    Objective: To determine the rates of diagnostic success and complications of computed tomography (CT)-guided percutaneous biopsy of bone lesions suspected for malignancy. Materials and Methods: Retrospective study including 186 cases of CT-guided percutaneous biopsies of bone lesions in the period from January, 2010 to December, 2012. All the specimens were obtained with 8-10 gauge needles. The following data were collected: demographics, previous history of malignancy, data related to the lesion, to the procedure, and to histological results. Results: Most patients were women (57%), and the mean age was 53.0 ± 16.4 years. In 139 cases (74.6%), there was diagnostic suspicion of metastasis and the most common primary tumors were breast (32.1%) and prostate (11.8%). The bones most commonly involved were spine (36.0%), hip (32.8%) and long bones (18.3%). Complications occurred in only three cases (1.6%) including bone fracture, paraesthesia with functional impairment, and needle breakage requiring surgical removal. The specimens collected from 183 lesions (98.4%) were considered appropriate for diagnosis. Malignant results were more frequently found in patients who had a suspected secondary lesion and history of known malignancy (p < 0.001), and in patients who underwent PET/CT-guided procedures (p = 0.011). Conclusion: CT-guided percutaneous biopsy is a safe and effective procedure for the diagnosis of suspicious bone lesions. (author)

  7. Oropharynx lesion biopsy

    Science.gov (United States)

    ... as papilloma) Fungal infections (such as candida) Histoplasmosis Oral lichen planus Precancerous sore (leukoplakia) Viral infections (such as Herpes simplex) Risks Risks of the procedure may ... Throat lesion biopsy; Biopsy - mouth or throat; Mouth lesion biopsy; Oral cancer - biopsy ...

  8. Diagnostic yield of pleural biopsy in exudative pleural effusion.

    Science.gov (United States)

    Devkota, K C; Chokhani, R; Gautam, S

    2014-09-01

    To know the diagnostic role of pleural biopsy in determining underlying etiological causes of exudative pleural effusion. A total of 47 patients, aged 16-104 years with mean age of 47.36 years, of either sex, with exudative pleural effusion underwent closed pleural biopsy with Abram's needle in standard way. Average 4-6 biopsy specimens were obtained from each patient, which were sent for histopathological examination. In this study, 47 cases of exudative pleural effusion were included, among them 26 (55.31%) cases were male and 21 (44.69%) were female with mean age 47.36 years. Cough was reported by 42 (89.36%) cases, expectoration 28 (59.57%), hemoptysis 3 (6.38%), breathlessness 27 (57.44%), wheezing 3 (6.38%), chest pain 38 (80.85%) and fever by 30 (63.82%) cases. Out of 47 cases, 28 (59.57%) cases had a positive yield, whereas in 19 (40.43%) cases the result was nonspecific inflammation. Out of 28 (59.57%) cases with positive yield 21 (44.68%) were found to have granulomatous inflammation and 10 (21.28%) cases were malignant. Among malignant pleural effusion, 4 cases were squamous cell carcinoma; 3 small cell carcinoma; 1 case adenocarcinoma and 1 case found to have mesothelioma. Tuberculosis and malignancy are the two most common causes of exudative pleural effusion in our set up. Pleural biopsy is a safe, simple and well validated diagnostic tool that helps us to differentiate between malignancy and tuberculosis.

  9. Imaging-histologic discordance at sonographically guided percutaneous biopsy of breast lesions

    International Nuclear Information System (INIS)

    Kim, Min Jung; Kim, Eun-Kyung; Park, Sun Young; Jung, Hae Kyoung; Park, Byeong-Woo; Kim, Haeryung; Oh, Ki Keun

    2008-01-01

    Objective: To determine the frequency of imaging-histologic discordance at percutaneous breast biopsy and to evaluate differences in clinical and radiologic findings between pathologically upgraded lesions and non-upgraded lesions. Materials and methods: From February 2000 to June 2005, we reviewed 386 cases that had suspicious imaging findings but yielded benign histology at US-core needle biopsy and that underwent subsequent excisional biopsy. In 74 of 386 cases, the benign histology at core needle biopsy could not provide a satisfactory explanation for the radiologically suspicious lesions. The clinical, radiologic and histologic findings were reviewed for those 74 cases that were classified as the upgrade group and the non-upgrade group after excisional biopsy. Results: The upgrade rate was 17.6% (95% confidence interval, 10.6-27.8%, 13 of 74 cases) revealed upgraded pathology at the subsequent excisional biopsy. Besides the size of masses, there were no statistically significant differences in imaging findings between the upgrade and non-upgrade groups at excisional biopsy. Conclusion: This upgrade rate of 17.6% suggests that excisional biopsy or re-biopsy is warranted in those cases presenting imaging-histologic discordance at US-guided core biopsy

  10. Detection of hepatitis C viral RNA sequences in fresh and paraffin-embedded liver biopsy specimens of non-A, non-B hepatitis patients

    NARCIS (Netherlands)

    Bresters, D.; Cuypers, H. T.; Reesink, H. W.; Chamuleau, R. A.; Schipper, M. E.; Boeser-Nunnink, B. D.; Lelie, P. N.; Jansen, P. L.

    1992-01-01

    In this study methods of HCV-RNA detection in fresh frozen and formalin-fixed, paraffin-embedded liver biopsies are described. Of 22 untreated chronic non-A, non-B hepatitis patients and 6 control patients, a plasma sample and part of a liver biopsy were freshly frozen for hepatitis C virus (HCV)

  11. Respiratory analysis of coupled mitochondria in cryopreserved liver biopsies

    Directory of Open Access Journals (Sweden)

    Mercedes García-Roche

    2018-07-01

    Full Text Available The aim of this work was to develop a cryopreservation method of small liver biopsies for in situ mitochondrial function assessment. Herein we describe a detailed protocol for tissue collection, cryopreservation, high-resolution respirometry using complex I and II substrates, calculation and interpretation of respiratory parameters. Liver biopsies from cow and rat were sequentially frozen in a medium containing dimethylsulfoxide as cryoprotectant and stored for up to 3 months at −80 °C. Oxygen consumption rate studies of fresh and cryopreserved samples revealed that most respiratory parameters remained unchanged. Additionally, outer mitochondrial membrane integrity was assessed adding cytochrome c, proving that our cryopreservation method does not harm mitochondrial structure. In sum, we present a reliable way to cryopreserve small liver biopsies without affecting mitochondrial function. Our protocol will enable the transport and storage of samples, extending and facilitating mitochondrial function analysis of liver biopsies. Keywords: Cryopreservation, Mitochondria, Biopsy, Oxygen consumption rate, High-resolution respirometry, Mitochondrial function

  12. Histology of Testicular Biopsies Obtained for Experimental Fertility Preservation Protocol in Boys with Cancer.

    Science.gov (United States)

    Pietzak, Eugene J; Tasian, Gregory E; Tasian, Sarah K; Brinster, Ralph L; Carlson, Claire; Ginsberg, Jill P; Kolon, Thomas F

    2015-11-01

    Cryopreservation of testicular tissue with subsequent reimplantation after therapy has the potential to preserve fertility for prepubertal boys with cancer. We present the histology and feasibility of testicular tissue procurement for this novel approach. We performed a prospective cohort study of boys at significant risk for treatment associated gonadotoxicity who were eligible for an experimental research protocol between 2008 and 2011. Open testicular biopsy was performed while the patients were anesthetized for another treatment related procedure. Half of the specimen was reserved for cryopreservation, while the other half was used for research purposes. Semithin sections of the biopsy specimens were evaluated for histological features and compared to age adjusted reference values. A total of 34 boys underwent biopsy between March 2008 and October 2011. Of the patients 29 had solid tumors and 5 underwent hematopoietic stem cell transplantation for benign disease. A total of 27 patients had adequate tissue for histological analysis. Median patient age was 8.7 years (IQR 2.2 to 11.5). All children had either normal (81.5% of patients) or increased (18.5%) numbers of germ cells per tubule for their age. However, 5 of 26 patients (19%) older than 6 months had no evidence of adult dark spermatogonia and 9 of 16 (56%) older than 6 years had no evidence of primary spermatocytes on biopsy, which would be expected based on age norms. These findings are suggestive of abnormal germ cell maturation. The preliminary histological findings of abnormal spermatogenesis maturation in the testes of prepubertal boys with cancer warrants further investigation. Copyright © 2015 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  13. MR-guided biopsies

    International Nuclear Information System (INIS)

    Gehl, H.B.; Frahm, C.

    1998-01-01

    Biopsies were the first 'intervention' under MR guidance. After initial difficulties concerning ferromagnetic biopsy instruments and the design of MR scanners, the latest technological improvements rendered MR guidance for biopsies more feasible. In this article we illustrate present-day clinical experience in the field of abdominal, breast and bone biopsy. Important aspects regarding the different designs of 'interventional' MR scanners and the visualization of instruments for biopsy are discussed. (orig.) [de

  14. CT-guided transgluteal biopsy for systematic sampling of the prostate in patients without rectal access: a 13-year single-center experience.

    Science.gov (United States)

    Olson, Michael C; Atwell, Thomas D; Mynderse, Lance A; King, Bernard F; Welch, Timothy; Goenka, Ajit H

    2017-08-01

    The purpose of our study was to examine the safety and diagnostic utility of transgluteal CT-guided prostate biopsy for prostate sampling in patients without rectal access. Seventy-three biopsies were performed in 65 patients over a 13-year period (2002-2015). Mean prostate-specific antigen (PSA) at biopsy was 7.8 ng/mL (range 0.37-31.5). Electronic medical records were reviewed for procedural details and complications. Mean PSA and number of cores in malignant and benign cohorts were compared with Student's t test. Technical success rate was 97.3% (71/73; mean cores 8, range 3-28). Of these, 43.6% (31/71) yielded malignancy (mean Gleason score 7, range 6-10) and 56.3% (40/71) yielded benign tissue. The only complication was an asymptomatic periprostatic hematoma (1/73; 1.4%). In 14 patients who underwent surgery, Gleason scores were concordant in 71.4% (10/14) and discordant in 28.6% (4/14; Gleason 6 on biopsy but Gleason 7 on surgical specimen). Mean effective radiation dose was 18.5 mSv (median 15.0, range 4.4-86.2). There was no significant difference in either mean PSA (p = 0.06) or number of core specimens (p = 0.33) between malignant and benign cohorts. CT-guided transgluteal prostate biopsy is highly safe and reliable for the detection of prostate cancer in men without rectal access. • Prostate cancer detection in men without rectal access is challenging. • CT-guided transgluteal prostate biopsy is safe and effective in these patients. • CT-guided biopsy may be particularly effective in diagnosing high-grade prostate cancer. • Unilateral CT-guided biopsy may be effective in patients with focal lesions. • The radiation exposure with this technique is acceptable.

  15. Interobserver variability and feasibility of polymerase chain reaction-based assay in distinguishing ischemic colitis from Clostridium difficile colitis in endoscopic mucosal biopsies.

    Science.gov (United States)

    Wiland, Homer O; Procop, Gary W; Goldblum, John R; Tuohy, Marion; Rybicki, Lisa; Patil, Deepa T

    2013-06-01

    Polymerase chain reaction (PCR)-based assays using stool samples are currently the most effective method of detecting Clostridium difficile. This study examines the feasibility of this assay using mucosal biopsy samples and evaluates the interobserver reproducibility in diagnosing and distinguishing ischemic colitis from C difficile colitis. Thirty-eight biopsy specimens were reviewed and classified by 3 observers into C difficile and ischemic colitis. The findings were correlated with clinical data. PCR was performed on 34 cases using BD GeneOhm C difficile assay. The histologic interobserver agreement was excellent (κ= 0.86) and the agreement between histologic and clinical diagnosis was good (κ = 0.84). All 19 ischemic colitis cases tested negative (100% specificity) and 3 of 15 cases of C difficile colitis tested positive (20% sensitivity). C difficile colitis can be reliably distinguished from ischemic colitis using histologic criteria. The C difficile PCR test on endoscopic biopsy specimens has excellent specificity but limited sensitivity.

  16. Ultrasound-guided core needle biopsy for breast cancer

    International Nuclear Information System (INIS)

    Naqvi, S.Q.H.; Solangi, R.A.; Memon, M.; Solangi, R.A.

    2008-01-01

    To evaluate the efficacy of ultrasound-guided core needle biopsy (US-CNB) as a preoperative diagnostic modality for breast cancer. Females with solid and/or intermediate breast lesions visualized on ultrasonography. Apart from clinical work-up, all the above mentioned patients underwent ultrasound-guided core needle biopsy and excisional biopsy of their breast lesions. The histopathological diagnosis on ultrasound-guided core needle biopsy was then compared with the findings of the excisional biopsy. Out of the total 93 cases, 47(50.5%) had benign lesions on ultrasound; US-CNB showed 24 as fibroadenomata, four with chronic non-specific mastitis, five chronic suppurative mastitis, one tuberculosis, four fat necrosis, two lactational adenoma and seven cases with benign ductal hyperplasia without atypia. Nine (9.7%) cases showed suspicious abnormality on ultrasound; US-CNB revealed five cases with atypical ductal hyperplasia, one ductal carcinoma in situ and three invasive ductal carcinoma. Thirty seven (39.8%) cases were highly suggestive of malignancy on ultrasound; US-CNB showed 34 as invasive ductal carcinoma, two invasive lobular and one medullary carcinoma. Excisional biopsy confirmed the diagnosis of ultrasound-guided core needle biopsy in all cases except four; one case of chronic suppurative mastitis was diagnosed as that of tuberculosis and three cases of atypial ductal hyperplasia as invasive ductal carcinoma. Hence there was no false positive case, but four (4.3%) false negative cases. The sensitivity of the US-CNB was thus 100% and specificity 91.1%. Ultrasound guided core needle biopsy is a satisfactory procedure for the histopathological diagnosis of breast lesions. Any unsatisfactory, suspicious or atypical change on US-CNB should be followed by an open biopsy. (author)

  17. Applying the Principles of Lean Production to Gastrointestinal Biopsy Handling: From the Factory Floor to the Anatomic Pathology Laboratory.

    Science.gov (United States)

    Sugianto, Jessica Z; Stewart, Brian; Ambruzs, Josephine M; Arista, Amanda; Park, Jason Y; Cope-Yokoyama, Sandy; Luu, Hung S

    2015-01-01

    To implement Lean principles to accommodate expanding volumes of gastrointestinal biopsies and to improve laboratory processes overall. Our continuous improvement (kaizen) project analyzed the current state for gastrointestinal biopsy handling using value-stream mapping for specimens obtained at a 487-bed tertiary care pediatric hospital in Dallas, Texas. We identified non-value-added time within the workflow process, from receipt of the specimen in the histology laboratory to the delivery of slides and paperwork to the pathologist. To eliminate non-value-added steps, we implemented the changes depicted in a revised-state value-stream map. Current-state value-stream mapping identified a total specimen processing time of 507 minutes, of which 358 minutes were non-value-added. This translated to a process cycle efficiency of 29%. Implementation of a revised-state value stream resulted in a total process time reduction to 238 minutes, of which 89 minutes were non-value-added, and an improved process cycle efficiency of 63%. Lean production principles of continuous improvement and waste elimination can be successfully implemented within the clinical laboratory.

  18. Bone marrow solid core biopsy needle: a critical assessment of the utility, benefits and limitations of the instruments employed in current day haematology and oncology.

    Science.gov (United States)

    Islam, Anwarul

    2018-06-01

    The optimal clinical evaluation of the bone marrow requires an examination of air-dried and well-stained films of the aspirated tissue along with a histopathological evaluation of adequately processed and properly stained core biopsy specimens. A bone marrow evaluation can be essential in establishing a diagnosis, determining the efficacy of treatment in haematological disorders and to monitor haematological status of patients following bone marrow/stem cell transplantation. It is also an essential component of the staging process for newly diagnosed malignancies. Currently available bone marrow aspiration needles are quite satisfactory and if properly used provide good-quality specimens for morphological evaluation. However, if a bone marrow core biopsy is concerned, several needles are currently in use but not all of them provide good-quality biopsy specimens for histological evaluation or are user friendly. We have compared the recently introduced Moeller Medical single use bone marrow core biopsy needle with the Jamshidi needle with marrow acquisition cradle (CareFusion), J-needle (Cardinal Health) and OnControl device (Vidacare). It is concluded that the Moeller Medical needle system has definite advantages over others and is recommended for routine use. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  19. Development of a permanently controllable rotating biopsy device. Pt. I. Theoretical considerations and in-vitro results for five different prototypes

    International Nuclear Information System (INIS)

    Schaefer, Philipp Jost; Jahnke, T.; Andres, H.; Heller, M.; Schaefer, F.K.; Hedderich, J.

    2009-01-01

    Purpose: to develop different prototypes of permanently controllable rotating biopsy devices with determination of the most efficient prototype in biopsies in bovine myocardium. Materials and Methods: Five different prototypes of 18-gauge rotating biopsy devices were designed and constructed, four (1-4) with various drill-like cutting edges and one (5) cannula type with a lancet-like helically bent cutting edge. Using bovine myocardium as the biopsy tissue, n = 100 specimens per prototype were obtained, and a quantitative analysis including tissue fragmentation, length in mm and weight in mg was carried out. For statistical analysis, the chi-square test for tissue fragmentation and Kruskal-Wallis test for the parameters length and weight were calculated. Results: prototype 5 showed the highest rate of extraction of one-fragment specimens in n=66 cases and the lowest rate of failure to obtain tissue in n=11 cases. The mean length/weight were 4.15 mm/3.91 mg for prototype 1, 1.80 mm/1.66 mg for prototype 2, 4.61 mm/3.28 mg for prototype 3, 5.20 mm/3.74 mg for prototype 4, and 9.57 mm/6.97 mg for prototype 5. In all three categories, prototype 5 was significantly superior to the prototypes 1-4 with p < 0.001. Conclusion: the cannula type with a lancet-like helically bent cutting edge proved to be the most efficient prototype and may now be tested competitively against established automated biopsy devices in vitro. (orig.)

  20. Documenting the location of systematic transrectal ultrasound-guided prostate biopsies: correlation with multi-parametric MRI.

    Science.gov (United States)

    Turkbey, Baris; Xu, Sheng; Kruecker, Jochen; Locklin, Julia; Pang, Yuxi; Shah, Vijay; Bernardo, Marcelino; Baccala, Angelo; Rastinehad, Ardeshir; Benjamin, Compton; Merino, Maria J; Wood, Bradford J; Choyke, Peter L; Pinto, Peter A

    2011-03-29

    During transrectal ultrasound (TRUS)-guided prostate biopsies, the actual location of the biopsy site is rarely documented. Here, we demonstrate the capability of TRUS-magnetic resonance imaging (MRI) image fusion to document the biopsy site and correlate biopsy results with multi-parametric MRI findings. Fifty consecutive patients (median age 61 years) with a median prostate-specific antigen (PSA) level of 5.8 ng/ml underwent 12-core TRUS-guided biopsy of the prostate. Pre-procedural T2-weighted magnetic resonance images were fused to TRUS. A disposable needle guide with miniature tracking sensors was attached to the TRUS probe to enable fusion with MRI. Real-time TRUS images during biopsy and the corresponding tracking information were recorded. Each biopsy site was superimposed onto the MRI. Each biopsy site was classified as positive or negative for cancer based on the results of each MRI sequence. Sensitivity, specificity, and receiver operating curve (ROC) area under the curve (AUC) values were calculated for multi-parametric MRI. Gleason scores for each multi-parametric MRI pattern were also evaluated. Six hundred and 5 systemic biopsy cores were analyzed in 50 patients, of whom 20 patients had 56 positive cores. MRI identified 34 of 56 positive cores. Overall, sensitivity, specificity, and ROC area values for multi-parametric MRI were 0.607, 0.727, 0.667, respectively. TRUS-MRI fusion after biopsy can be used to document the location of each biopsy site, which can then be correlated with MRI findings. Based on correlation with tracked biopsies, T2-weighted MRI and apparent diffusion coefficient maps derived from diffusion-weighted MRI are the most sensitive sequences, whereas the addition of delayed contrast enhancement MRI and three-dimensional magnetic resonance spectroscopy demonstrated higher specificity consistent with results obtained using radical prostatectomy specimens.

  1. Unusual presentation and inconclusive biopsy render fibroadenoma ...

    African Journals Online (AJOL)

    Two young, nonlactating, nulliparous women presented with acutely painful breast masses. Sonographic features showed mixed echogenic masses. Core biopsies were not diagnostic, and surgical excision revealed infarcted fibroadenomas in both cases. Although fibroadenomas are common, they do not commonly infarct, ...

  2. Sonographically-guided vacuum-assisted biopsy with digital mammography-guided skin marking of suspicious breast microcalcifications: comparison of outcomes with stereotactic biopsy in Asian women.

    Science.gov (United States)

    Hahn, Soo Yeon; Shin, Jung Hee; Han, Boo-Kyung; Ko, Eun Young

    2011-02-01

    Management of suspicious microcalcifications in very thin breasts is problematic. To evaluate whether sonographically-guided vacuum-assisted biopsy (USVAB) with digital mammography-guided skin marking (DM) for the diagnosis of breast microcalcifications is comparable to stereotactic-guided vacuum-assisted biopsy (SVAB) in Asian women with thin breasts. Retrospective review was performed for 263 consecutive suspicious microcalcification lesions in 261 women who underwent USVAB with DM or SVAB using a prone table between January 2004 and December 2007. SVAB was performed for 190 lesions and USVAB for 73 lesions. Biopsy results were correlated with surgical pathology or followed up for at least 12 months. The diagnostic outcomes of SVAB and USVAB to diagnose microcalcifications were compared. Of 263 lesions, 104 (40%) underwent surgery and 159 (60%) were followed up. SVAB and USVAB groups showed similar final categories or the extent of microcalcifications. US visible lesions were 57 (78%) of 73 at USVAB and 14 (10%) of 140 at SVAB. Of 57 US visible lesions at USVAB, 29 (51%) were not found in initial US but were detectable with the help of DM. Specimen radiographs were negative in 2.1% of lesions at SVAB and in 4.1% at USVAB (p=0.4008). The under-estimation rate and false-negative rate were similar in SVAB and USVAB. US with DM facilitates US visibility of microcalcifications. USVAB with DM can produce acceptable biopsy results, as can SVAB, to diagnose breast microcalcifications in patients with thin breasts.

  3. Comparison of sonoelastography guided biopsy with systematic biopsy: impact on prostate cancer detection

    International Nuclear Information System (INIS)

    Pallwein, Leo; Struve, Peter; Aigner, Friedrich; Gradl, Johann; Schurich, Matthias; Frauscher, Ferdinand; Mitterberger, Michael; Horninger, Wolfgang; Bartsch, Georg; Pedross, Florian

    2007-01-01

    A prospective study was performed to determine the value of sonoelastography (SE) targeted biopsy for prostate cancer (PCa) detection. A series of 230 male screening volunteers was examined. Two independent examiners evaluated each subject. One single investigator performed ≤5 SE targeted biopsies into suspicious regions in the peripheral zone only. The stiffness of the lesion was displayed by SE and color-coded from red (soft) to blue (hard). Hard lesions were considered as malignant and targeted by biopsy. Subsequently, another examiner performed ten systematic biopsies. Cancer detection rates of the two techniques were compared. Cancer was detected in 81 of the 230 patients (35%), including 68 (30%) by SE targeted biopsy and in 58 (25%) by systematic biopsy. Cancer was detected by targeted biopsy alone in 23 patients (10%) and by systematic biopsy alone in 13 patients (6%). The detection rate for SE targeted biopsy cores (12.7% or 135 of 1,109 cores) was significantly better than for systematic biopsy cores (5.6% or 130 of 2,300 cores, P < 0.001). SE targeted biopsy in a patient with cancer was 2.9-fold more likely to detect PCa than systematic biopsy. SE targeted biopsy detected more cases of PCa than systematic biopsy, with fewer than half the number of biopsy cores in this prostate-specific antigen screening population. (orig.)

  4. Incidental intraductal papillomas (breast diagnosed on needle core biopsy do not need to be excised.

    Science.gov (United States)

    Jaffer, Shabnam; Bleiweiss, Ira J; Nagi, Chandandeep

    2013-01-01

    Most authors recommend excision of intraductal papillomas diagnosed on core needle biopsy. This leads to the question of whether or not excision is necessary for incidental intraductal papillomas on core needle biopsy as opposed to those corresponding to imaging findings. Using the pathology computerized data base we retrospectively identified 46 incidental intraductal papillomas diagnosed on core needle biopsy from 1/2000 to 12/2008. Clinical, radiologic, and pathologic information was gathered and correlated. All core needle biopsies were reviewed to confirm the diagnosis of incidental intraductal papillomas, and excision specimens reviewed when available. Of the 46 patients, follow-up information was available in only 38. The age of the patients ranged from 39 to 82 years (mean = 48 years). Most incidental intraductal papillomas were diagnosed by mammotome core needle biopsy (36 cases). A total of 33 cases were performed for calcifications with the following indications: clustered = 21, new = 4, pleomorphic = 3, increasing = 3, indeterminant = 2. The correlating diagnoses included the following: fibrocystic changes with calcium phosphate = 18 or calcium oxalate = 10, fibroadenoma with calcifications = 5. The three masses were: two cases of cystic papillary apocrine metaplasia (I Ultrasound and 1 MRI) and 1 fibroadenoma (Ultrasound). In all cases, the intraductal papillomas were ≤0.2 cm, were not associated with calcifications, and were incidental to them or the underlying mass. A total of 14 patients underwent excision, whereas the remaining 24 have remained radiologically stable for over 12 months. The excision specimen findings were: fibrocystic changes = 8 and intraductal papilloma = 6. With the exception of one case, all the intraductal papilloma remained incidental to imaging findings. In this solitary case, the calcifications were described as pleomorphic and corresponded to fibrocystic changes calcifications on core needle

  5. Detection, mapping, and quantification of single walled carbon nanotubes in histological specimens with photoacoustic microscopy.

    Science.gov (United States)

    Avti, Pramod K; Hu, Song; Favazza, Christopher; Mikos, Antonios G; Jansen, John A; Shroyer, Kenneth R; Wang, Lihong V; Sitharaman, Balaji

    2012-01-01

    In the present study, the efficacy of multi-scale photoacoustic microscopy (PAM) was investigated to detect, map, and quantify trace amounts [nanograms (ng) to micrograms (µg)] of SWCNTs in a variety of histological tissue specimens consisting of cancer and benign tissue biopsies (histological specimens from implanted tissue engineering scaffolds). Optical-resolution (OR) and acoustic-resolution (AR)--Photoacoustic microscopy (PAM) was employed to detect, map and quantify the SWCNTs in a variety of tissue histological specimens and compared with other optical techniques (bright-field optical microscopy, Raman microscopy, near infrared (NIR) fluorescence microscopy). Both optical-resolution and acoustic-resolution PAM, allow the detection and quantification of SWCNTs in histological specimens with scalable spatial resolution and depth penetration. The noise-equivalent detection sensitivity to SWCNTs in the specimens was calculated to be as low as ∼7 pg. Image processing analysis further allowed the mapping, distribution, and quantification of the SWCNTs in the histological sections. The results demonstrate the potential of PAM as a promising imaging technique to detect, map, and quantify SWCNTs in histological specimens, and could complement the capabilities of current optical and electron microscopy techniques in the analysis of histological specimens containing SWCNTs.

  6. Detection, mapping, and quantification of single walled carbon nanotubes in histological specimens with photoacoustic microscopy.

    Directory of Open Access Journals (Sweden)

    Pramod K Avti

    Full Text Available In the present study, the efficacy of multi-scale photoacoustic microscopy (PAM was investigated to detect, map, and quantify trace amounts [nanograms (ng to micrograms (µg] of SWCNTs in a variety of histological tissue specimens consisting of cancer and benign tissue biopsies (histological specimens from implanted tissue engineering scaffolds.Optical-resolution (OR and acoustic-resolution (AR--Photoacoustic microscopy (PAM was employed to detect, map and quantify the SWCNTs in a variety of tissue histological specimens and compared with other optical techniques (bright-field optical microscopy, Raman microscopy, near infrared (NIR fluorescence microscopy.Both optical-resolution and acoustic-resolution PAM, allow the detection and quantification of SWCNTs in histological specimens with scalable spatial resolution and depth penetration. The noise-equivalent detection sensitivity to SWCNTs in the specimens was calculated to be as low as ∼7 pg. Image processing analysis further allowed the mapping, distribution, and quantification of the SWCNTs in the histological sections.The results demonstrate the potential of PAM as a promising imaging technique to detect, map, and quantify SWCNTs in histological specimens, and could complement the capabilities of current optical and electron microscopy techniques in the analysis of histological specimens containing SWCNTs.

  7. Limited endoscopic transsphenoidal approach for cavernous sinus biopsy: illustration of 3 cases and discussion.

    Science.gov (United States)

    Graillon, T; Fuentes, S; Metellus, P; Adetchessi, T; Gras, R; Dufour, H

    2014-01-01

    Advances in transsphenoidal surgery and endoscopic techniques have opened new perspectives for cavernous sinus (CS) approaches. The aim of this study was to assess the advantages and disadvantages of limited endoscopic transsphenoidal approach, as performed in pituitary adenoma surgery, for CS tumor biopsy illustrated with three clinical cases. The first case was a 46-year-old woman with a prior medical history of parotid adenocarcinoma successfully treated 10 years previously. The cavernous sinus tumor was revealed by right third and sixth nerve palsy and increased over the past three years. A tumor biopsy using a limited endoscopic transsphenoidal approach revealed an adenocarcinoma metastasis. Complementary radiosurgery was performed. The second case was a 36-year-old woman who consulted for diplopia with right sixth nerve palsy and amenorrhea with hyperprolactinemia. Dopamine agonist treatment was used to restore the patient's menstrual cycle. Cerebral magnetic resonance imaging (MRI) revealed a right sided CS tumor. CS biopsy, via a limited endoscopic transsphenoidal approach, confirmed a meningothelial grade 1 meningioma. Complementary radiosurgery was performed. The third case was a 63-year-old woman with progressive installation of left third nerve palsy and visual acuity loss, revealing a left cavernous sinus tumor invading the optic canal. Surgical biopsy was performed using an enlarged endoscopic transsphenoidal approach to the decompress optic nerve. Biopsy results revealed a meningothelial grade 1 meningioma. Complementary radiotherapy was performed. In these three cases, no complications were observed. Mean hospitalization duration was 4 days. Reported anatomical studies and clinical series have shown the feasibility of reaching the cavernous sinus using an endoscopic endonasal approach. Trans-foramen ovale CS percutaneous biopsy is an interesting procedure but only provides cell analysis results, and not tissue analysis. However, radiotherapy and

  8. Sentinel lymph node biopsy in node-negative squamous cell carcinoma of the oral cavity and oropharynx.

    LENUS (Irish Health Repository)

    Burns, P

    2012-02-01

    OBJECTIVES: Considerable controversy exists regarding the merits of elective neck dissection in patients with early stage oral cavity and oropharyngeal squamous cell carcinoma. It is highly desirable to have a method of identifying those patients who would benefit from further treatment of the neck when they are clinically node-negative. The purpose of the present study was to examine the use of sentinel lymph node biopsy in identifying occult neck disease in a cohort of patients with node-negative oral cavity and oropharyngeal squamous cell carcinoma. DESIGN: We evaluated a total of 13 patients with oral cavity and oropharyngeal cancer who were clinically and radiologically node-negative. RESULTS: A sentinel lymph node was found in all 13 patients, revealing metastatic disease in five patients, four of whom had one or more positive sentinel lymph nodes. There was one false negative result, in which the sentinel lymph node was negative for tumour whereas histological examination of the neck dissection specimen showed occult disease. CONCLUSION: In view of these findings, we would recommend the use of sentinel lymph node biopsy in cases of oral cavity and oropharyngeal squamous cell carcinoma, in order to aid the differentiation of those patients whose necks are harbouring occult disease and who require further treatment.

  9. Comparison between endobronchial forceps-biopsy and cryo-biopsy by flexible

    Directory of Open Access Journals (Sweden)

    Sami El-Dahdouh

    2016-01-01

    Conclusions: We concluded that cryoprobe biopsies were more successful than forceps biopsies in the diagnosis of lung cancer. Nevertheless, further investigations are warranted to determine an efficacy of cryoprobe biopsy procedures and a rationale to use as a part of routine flexible bronchoscopy.

  10. Stereotaxic core needle biopsy of breast microcalcifications obtained using a standard mammography table with an add-on unit

    International Nuclear Information System (INIS)

    Ward, S.E.; Taves, D.H.; McCurdy, L.I.

    2000-01-01

    To demonstrate the reliability of stereotaxic biopsy of indeterminate microcalcifications using a standard mammography table with an add-on unit. In 121 cases of indeterminate microcalcifications, core biopsy was performed using a standard mammography table with an add-on stereotaxic unit. Microcalcifications were identified on radiography of core specimens. Microcalcifications and a definitive histologic diagnosis were obtained in 112 core biopsies (92.6%), with no significant complications. In 23 lesions frank malignancy was diagnosed, and all of these diagnoses were confirmed on surgery. Pathologic examination suggested carcinoma in 4 lesions, and open biopsy confirmed malignancy in 3 of these cases. Four lesions showed atypical ductal hyperplasia. Benign disease was diagnosed in 81 lesions, of which 78 remained stable on mammographic follow-up (mean 16 months later) and 3 were subjected to surgical biopsy (of which 1 was malignant and 2 were benign). Nine cases were technically unsatisfactory because microcalcifications were not sampled. Stereotaxic core biopsy performed with an add-on unit is a safe and reliable technique for biopsy of indeterminate microcalcifications. For successful biopsy, microcalcifications must be harvested. Pathologic results should be correlated with mammographic findings. The accuracy rate compares favourably with results reported using prone biopsy tables. In an era of cost containment, this alternative to prone biopsy tables could result m significant savings in terms of capital investment and use of hospital rooms. In this study, surgical biopsy could have been avoided in 64.5% of cases. (author)

  11. Prostate biopsy after ano-rectal resection: value of CT-guided trans-gluteal biopsy

    International Nuclear Information System (INIS)

    Cantwell, Colin P.; Hahn, Peter F.; Gervais, Debra A.; Mueller, Peter R.

    2008-01-01

    We describe our single-institutional experience with computed tomography (CT)-guided percutaneous transgluteal biopsy of the prostate in patients in whom transrectal ultrasound-guided biopsy is precluded by prior ano-rectal resection. Between March 1995 and April 2007, 22 patients had 34 prostate biopsies (mean age 68; mean PSA 29 ng/ml; mean follow-up 6.1 years). The charts of patients who had transgluteal biopsy were reviewed for demographic, complications and pathology. Ninety-five percent (21/22) of primary biopsies were diagnostic. Of the 21 diagnostic biopsies, 11 were positive for prostate cancer and ten were definitive benign samples. Seventy-three percent (8/11) of the patients had progressive PSA elevation that mandated 11 further prostate biopsies. Six patients had a second biopsy, one patient had a third and one patient had a fourth biopsy. Among patients who had serial biopsies, 38% (3/8) had prostate cancer. No complications or death occurred. A malignant biopsy was not significantly associated with core number (P = 0.58) or a high PSA level (P 0.15). CT-guided transgluteal biopsy of the prostate is safe and effective. (orig.)

  12. CT-guided transgluteal biopsy for systematic sampling of the prostate in patients without rectal access: a 13-year single-center experience

    Energy Technology Data Exchange (ETDEWEB)

    Olson, Michael C.; Atwell, Thomas D.; King, Bernard F.; Welch, Timothy; Goenka, Ajit H. [Mayo Clinic, Department of Radiology, Rochester, MN (United States); Mynderse, Lance A. [Mayo Clinic, Department of Urology, Rochester, MN (United States)

    2017-08-15

    The purpose of our study was to examine the safety and diagnostic utility of transgluteal CT-guided prostate biopsy for prostate sampling in patients without rectal access. Seventy-three biopsies were performed in 65 patients over a 13-year period (2002-2015). Mean prostate-specific antigen (PSA) at biopsy was 7.8 ng/mL (range 0.37-31.5). Electronic medical records were reviewed for procedural details and complications. Mean PSA and number of cores in malignant and benign cohorts were compared with Student's t test. Technical success rate was 97.3% (71/73; mean cores 8, range 3-28). Of these, 43.6% (31/71) yielded malignancy (mean Gleason score 7, range 6-10) and 56.3% (40/71) yielded benign tissue. The only complication was an asymptomatic periprostatic hematoma (1/73; 1.4%). In 14 patients who underwent surgery, Gleason scores were concordant in 71.4% (10/14) and discordant in 28.6% (4/14; Gleason 6 on biopsy but Gleason 7 on surgical specimen). Mean effective radiation dose was 18.5 mSv (median 15.0, range 4.4-86.2). There was no significant difference in either mean PSA (p = 0.06) or number of core specimens (p = 0.33) between malignant and benign cohorts. CT-guided transgluteal prostate biopsy is highly safe and reliable for the detection of prostate cancer in men without rectal access. (orig.)

  13. Biopsies of colorectal clinical polyps--emergence of diagnostic information on deeper levels

    DEFF Research Database (Denmark)

    Warnecke, Mads; Engel, Ulla Højholt; Bernstein, Inge

    2009-01-01

    an increased risk of CRC (hereditary, n=19, including 15 hereditary non-polyposis colorectal cancer (HNPCC) cases). Sixty-five (13.5%) of the 480 samples were classified as NDB (normal morphology n=49, suspicious of adenoma n=5, suspicious of HP n=11), constituting roughly 10% of all biopsies from......Although the occasional appearance of a normal histology of biopsies from endoscopic colorectal (CR) polyps is generally held knowledge, its prevalence has rarely been focused on, and the yield of additional sections in such cases has been previously addressed in merely four communications...... specimens were obtained from 245 endoscopies and stratified in the following categories according to the clinical indications: relevant symptoms (symptomatic, n=127), previously documented sporadic large bowel neoplasia (follow-up, n=99), and documented or presumed hereditary condition that confer...

  14. Does a previous prostate biopsy-related acute bacterial prostatitis affect the results of radical prostatectomy?

    Science.gov (United States)

    Türk, Hakan; Ün, Sitki; Arslan, Erkan; Zorlu, Ferruh

    2018-01-01

    To The standard technique for obtaining a histologic diagnosis of prostatic carcinomas is transrectal ultrasound guided prostate biopsy. Acute prostatitis which might develop after prostate biopsy can cause periprostatic inflammation and fibrosis. In this study, we performed a retrospective review of our database to determine whether ABP history might affect the outcome of RP. 441 RP patients who were operated in our clinic from 2002 to 2014 were included in our study group. All patients' demographic values, PSA levels, biopsy and radical prostatectomy specimen pathology results and their perioperative/postoperative complications were evaluated. There were 41 patients in patients with acute prostatitis following biopsy and 397 patients that did not develop acute prostatitis. Mean blood loss, transfusion rate and operation period were found to be significantly higher in ABP patients. Hospitalization period and reoperation rates were similar in both groups. However, post-op complications were significantly higher in ABP group. Even though it does not affect oncological outcomes, we would like to warn the surgeons for potential complaints during surgery in ABP patients. Copyright® by the International Brazilian Journal of Urology.

  15. Does a previous prostate biopsy-related acute bacterial prostatitis affect the results of radical prostatectomy?

    Directory of Open Access Journals (Sweden)

    Hakan Türk

    Full Text Available ABSTRACT Objective To The standard technique for obtaining a histologic diagnosis of prostatic carcinomas is transrectal ultrasound guided prostate biopsy. Acute prostatitis which might develop after prostate biopsy can cause periprostatic inflammation and fibrosis. In this study, we performed a retrospective review of our database to determine whether ABP history might affect the outcome of RP. Materials and Methods 441 RP patients who were operated in our clinic from 2002 to 2014 were included in our study group. All patients’ demographic values, PSA levels, biopsy and radical prostatectomy specimen pathology results and their perioperative/ postoperative complications were evaluated. Results There were 41 patients in patients with acute prostatitis following biopsy and 397 patients that did not develop acute prostatitis. Mean blood loss, transfusion rate and operation period were found to be significantly higher in ABP patients. Hospitalization period and reoperation rates were similar in both groups. However, post-op complications were significantly higher in ABP group. Conclusion Even though it does not affect oncological outcomes, we would like to warn the surgeons for potential complaints during surgery in ABP patients.

  16. Signet Ring Cell Carcinoma of the Extrahepatic Bile Duct Diagnosed by Preoperative Biopsy: A Case Report

    Directory of Open Access Journals (Sweden)

    Emiri Kita

    2014-11-01

    Full Text Available A 73-year-old woman was admitted because of obstructive jaundice. Computed tomography revealed a stricture in the lower bile duct with enhanced bile duct wall. Endoscopic retrograde cholangiopancreatography (ERCP revealed a tapering stenosis at the lower bile duct. Transpapillary histological biopsy using biopsy forceps through ERCP was performed; the diagnosis of signet ring cell carcinoma (SRCC of the bile duct was established. Regional lymph node enlargement and distant metastases were not detected on diagnostic imaging. Pancreaticoduodenectomy with pylorus preservation was performed. Histological examination of the resected specimen confirmed SRCC of the extrahepatic bile duct coexisting with adenocarcinoma (ADC of the extrahepatic bile duct with negative resection margins. However, tumor cells directly invaded the pancreatic parenchyma and the muscle layer of the duodenum, prompting us to administer adjuvant chemotherapy to the patient, with no sign of tumor recurrence at 1-year follow-up. Almost all tumors originating from the extrahepatic bile duct are ADC and other histological variants are rare. Of these, SRCC is extremely rare and only four cases have been reported. Furthermore, to the best of our knowledge, this is the first case report regarding the preoperative diagnosis of SRCC of the bile duct. Current reports indicate that younger age and Asian ethnicity are the clinical features of SRCC of the extrahepatic bile duct. Immunohistochemical staining of CK7, CK20 and MUC2 may be useful for predicting prognosis. Chemotherapy has not resulted in increased survival rates and only surgical resection currently serves as a curative treatment.

  17. Touch imprint cytology of prostate core needle biopsy specimens: A useful method for immediate reporting of prostate cancer

    Directory of Open Access Journals (Sweden)

    Berna Aytac

    2012-01-01

    Conclusions: TIC smears can provide an immediate and reliable cytological diagnosis of prostate carcinoma. It may clearly help the rapid detection of carcinoma, particularly in highly suspected cases that had negative routine biopsy results for malignancy with abnormal serum prostate specific antigen (PSA levels and atypical digital rectal examination.

  18. Bone lesion biopsy

    Science.gov (United States)

    Bone biopsy; Biopsy - bone ... the cut, then pushed and twisted into the bone. Once the sample is obtained, the needle is ... sample is sent to a lab for examination. Bone biopsy may also be done under general anesthesia ...

  19. Open lung biopsy

    Science.gov (United States)

    Biopsy - open lung ... An open lung biopsy is done in the hospital using general anesthesia . This means you will be asleep and ... The open lung biopsy is done to evaluate lung problems seen on x-ray or CT scan .

  20. Bronchoscopic intratumoral injection of tranexamic acid to prevent excessive bleeding during multiple forceps biopsies of lesions with a high risk of bleeding: a prospective case series

    International Nuclear Information System (INIS)

    Zamani, Adil

    2014-01-01

    Significant bleeding may occur following endobronchial forceps biopsy or brushing of necrotic or hypervascular tumors in the airways. In some cases, methods such as endobronchial instillation of iced saline lavage and epinephrine may fail to control bleeding. The present study evaluated the efficacy and safety of a new bronchoscopic technique using intratumoral injection of tranexamic acid (IIT) for control of bleeding during forceps biopsy in patients with endobronchial tumors with a high risk of bleeding. The study was a prospective case series carried out in a single center. Bronchoscopic IIT was performed in those patients who had endoscopically visible tumoral lesions with persistent active bleeding following the first attempt at bronchoscopic sampling. Tranexamic acid (TEA) was injected through a 22-gauge Wang cytology needle into the lesion in nominal doses of 250–500 mg. After 2–3 minutes, multiple forceps biopsy specimens were obtained from the lesion. Of the 57 consecutive patients included in the study, 20 patients (35.1%) underwent bronchoscopic IIT. The first attempt in 18 patients was endobronchial forceps biopsy (EBB), and because of a high risk of bleeding, the first attempt for the remaining two patients, who were on continuous dual antiplatelet therapy (aspirin and clopidogrel), employed endobronchial needle aspiration (EBNA) as a precautionary measure. Following IIT, subsequent specimens were obtained using EBB in all patients. Multiple forceps biopsy specimens (3–10) were obtained from the lesions (8 necrotic and 12 hypervascular) without incurring active bleeding. The following histopathologic diagnoses were made: squamous cell carcinoma (n = 14), adenocarcinoma (n = 2), small-cell lung cancer (n = 3), and malignant mesenchymal tumor (n = 1). No side effects of TEA were observed. Bronchoscopic IIT is a useful and safe technique for controlling significant bleeding from a forceps biopsy procedure and can be considered as a pre-biopsy

  1. Kidney biopsy

    Science.gov (United States)

    ... the kidney (in rare cases, may require a blood transfusion) Bleeding into the muscle, which might cause soreness Infection (small risk) Alternative Names Renal biopsy; Biopsy - kidney Images Kidney anatomy ...

  2. cDNA Microarray Analysis of Serially Sampled Cervical Cancer Specimens From Patients Treated With Thermochemoradiotherapy

    International Nuclear Information System (INIS)

    Borkamo, Erling Dahl; Schem, Baard-Christian; Fluge, Oystein; Bruland, Ove; Dahl, Olav; Mella, Olav

    2009-01-01

    Purpose: To elucidate changes in gene expression after treatment with regional thermochemoradiotherapy in locally advanced squamous cell cervical cancer. Methods and Materials: Tru-Cut biopsy specimens were serially collected from 16 patients. Microarray gene expression levels before and 24 h after the first and second trimodality treatment sessions were compared. Pathway and network analyses were conducted by use of Ingenuity Pathways Analysis (IPA; Ingenuity Systems, Redwood City, CA). Single gene expressions were analyzed by quantitative real-time reverse transcription-polymerase chain reaction. Results: We detected 53 annotated genes that were differentially expressed after trimodality treatment. Central in the three top networks detected by IPA were interferon alfa, interferon beta, and interferon gamma receptor; nuclear factor κB; and tumor necrosis factor, respectively. These genes encode proteins that are important in regulation cell signaling, proliferation, gene expression, and immune stimulation. Biological processes over-represented among the 53 genes were fibrosis, tumorigenesis, and immune response. Conclusions: Microarrays showed minor changes in gene expression after thermochemoradiotherapy in locally advanced cervical cancer. We detected 53 differentially expressed genes, mainly involved in fibrosis, tumorigenesis, and immune response. A limitation with the use of serial biopsy specimens was low quality of ribonucleic acid from tumors that respond to highly effective therapy. Another 'key limitation' is timing of the post-treatment biopsy, because 24 h may be too late to adequately assess the impact of hyperthermia on gene expression.

  3. Emergency surgery for lung cancer with abscess formation after transbronchial biopsy

    OpenAIRE

    Takanashi, Yusuke; Miyashita, Koichi; Tajima, Shogo; Hayakawa, Takamitsu; Neyatani, Hiroshi; Funai, Kazuhito

    2017-01-01

    Abscess formation in lung cancer after transbronchial biopsy (TBB) is a rare complication with no standard consensus on a coping strategy or prophylaxis. We describe an instructive case of lung cancer which developed into an abscess after TBB. An 80?year?old man with poorly controlled diabetes mellitus underwent TBB for diagnosing a mass lesion in the left upper lobe. The TBB specimen confirmed a diagnosis of lung cancer, and he was scheduled for radical surgery. However, the tumour was revea...

  4. Differentiation of prostatitis and prostate cancer by using diffusion-weighted MR imaging and MR-guided biopsy at 3 T

    NARCIS (Netherlands)

    Nagel, Klaas N.A.; Schouten, Martijn G.; Hambrock, Thomas; Litjens, Geert J.S.; Hoeks, Caroline; ten Haken, Bernard; Barentsz, Jelle O.; Fütterer, Johannes Jacobus; Fütterer, Jurgen J.

    2013-01-01

    Purpose To determine if prostatitis and prostate cancer (PCa) can be distinguished by using apparent diffusion coefficients (ADCs) on magnetic resonance (MR) images, with specimens obtained at MR-guided biopsy as the standard of reference. Materials and Methods The need for institutional review

  5. Feasibility of contrast-enhanced ultrasound-guided biopsy of sentinel lymph nodes in dogs.

    Science.gov (United States)

    Gelb, Hylton R; Freeman, Lynetta J; Rohleder, Jacob J; Snyder, Paul W

    2010-01-01

    Our goal was to develop and validate a technique to identify the sentinel lymph nodes of the mammary glands of healthy dogs with contrast-enhanced ultrasound, and evaluate the feasibility of obtaining representative samples of a sentinel lymph node under ultrasound guidance using a new biopsy device. Three healthy intact female adult hounds were anesthetized and each received an injection of octafluoropropane-filled lipid microspheres and a separate subcutaneous injection of methylene blue dye around a mammary gland. Ultrasound was then used to follow the contrast agent through the lymphatic channel to the sentinel lymph node. Lymph node biopsy was performed under ultrasound guidance, followed by an excisional biopsy of the lymph nodes and a regional mastectomy procedure. Excised tissues were submitted for histopathologic examination and evaluated as to whether they were representative of the node. The ultrasound contrast agent was easily visualized with ultrasound leading up to the sentinel lymph nodes. Eight normal lymph nodes (two inguinal, one axillary in two dogs; two inguinal in one dog) were identified and biopsied. Lymphoid tissue was obtained from all biopsy specimens. Samples from four of eight lymph nodes contained both cortical and medullary lymphoid tissue. Contrast-enhanced ultrasound can be successfully used to image and guide minimally invasive biopsy of the normal sentinel lymph nodes draining the mammary glands in healthy dogs. Further work is needed to evaluate whether this technique may be applicable in patients with breast cancer or other conditions warranting evaluation of sentinel lymph nodes in animals.

  6. É a biópsia incisional útil na classificação dos carcinomas basocelulares? Is incisional biopsy helpful in the histopathological classification of basal cell carcinoma?

    Directory of Open Access Journals (Sweden)

    Maria Cristina de Lorenzo Messina

    2006-10-01

    Full Text Available FUNDAMENTOS: O carcinoma basocelular é tumor constituído por diferentes tipos histológicos, que demonstram diversificado potencial de agressividade. Sabe-se que a correlação entre os tipos histológicos de carcinoma basocelular encontrados no material de biópsia pré-operatória e no material da peça cirúrgica excisional não é total. Na literatura essa correlação varia de 42,7 a 80%. OBJETIVO: Avaliar a correlação entre os tipos histológicos de carcinoma basocelular nas biópsias incisionais e respectivas peças cirúrgicas excisionais. MÉTODOS: Análise retrospectiva de 70 casos de carcinoma basocelular primário submetidos a biópsia pré-operatória e cirurgia excisional. A avaliação histológica foi feita de modo padronizado, determinando tanto o tipo histológico predominante quanto os tipos histológicos acessórios encontrados no material das biópsias préoperatórias e nas peças cirúrgicas excisionais. RESULTADOS: Houve 78,3% de correlação entre tipo histológico predominante da biópsia e peça cirúrgica e 87% de correlação entre tipo histológico predominante e/ou tipo histológico acessório da biópsia e tipo histológico predominante da peça cirúrgica. CONCLUSÃO: A biópsia pré-operatória é útil para predizer o tipo histológico predominante de carcinoma basocelular da peça cirúrgica excisional na maioria dos casos. No entanto, é importante ressaltar que, quando descrito apenas o tipo histológico predominante encontrado na biópsia, ocorre 21,7% de falha no diagnóstico.BACKGROUND: Basal cell carcinoma is a tumor with many histologic types, each one with different aggressiveness potential. The known correlation between histologic types found in preoperative biopsy samples and excisional specimens is not absolute. Correspondence rates vary from 42.7 to 80.0% in medical literature. OBJECTIVE: To evaluate the correlation between histologic types of basal cell carcinoma in preoperative biopsies and

  7. Clinical application of CT-guided percutaneous puncturing biopsy of subcarinal lymph node

    International Nuclear Information System (INIS)

    Yuan Xiaodong; Wang Jianhua; Zuo Changjing; Tian Jianming

    2011-01-01

    Objective: To discuss the safety and clinical significance of CT-guided percutaneous puncturing biopsy of subcarinal lymph node. Methods: During the period of July 2006-July 2010, CT-guided percutaneous puncturing biopsy of subcarinal lymph node was carried out in 17 patients (11 males and 6 females, with an average age of 54 years) with enlarged subcarinal lymph nodes. The clinical data were retrospectively analyzed. Immediately after the puncturing procedure was completed, CT scanning was performed to observe if there any complications and to evaluate the safety of puncturing biopsy. Biopsy specimens were sent for pathological examination to assess the puncturing accuracy and to make the pathologic diagnosis. The clinical usefulness of this technique was evaluated. Results: Of the total 17 cases, successful puncturing into the enlarged subcarinal lymph nodes with single procedure was achieved in 14 and sufficient tissue sample was obtained. The biopsy failed in three cases at initial puncturing procedure as the needle could not be placed into the enlarged subcarinal lymph nodes, the puncturing biopsy had to given up in two patients because of hemoptysis and in another patient the second puncturing biopsy performed one week later was successful. The total technical successful rate was 88.2% (15/17). Of the fifteen cases with successful puncturing, definitive pathological diagnosis was obtained in 13 and the diagnosis was uncertain in the remaining two, with a diagnosis positive rate of 86.7% (13/15). Pathologically, the diagnoses included metastatic lymphadenopathy from lung cancer (n=10), proliferative inflammatory lymphadenopathy (n=2) and tuberculous enlargement of lymph nodes (n=1). Complications occurred in 4 patients (23.5%, 4/17), which mainly were pneumothorax and pulmonary hemorrhage. Conclusion: With high successful rate and diagnostic accuracy, CT-guided percutaneous puncturing biopsy of subcarinal lymph node is a safe and effective technique if the

  8. Biopsy results of Bosniak 2F and 3 cystic lesions

    DEFF Research Database (Denmark)

    Rasmussen, René; Hørlyck, Arne; Nielsen, Tommy Kjærgaard

    be helpful in clinical decisions. Material and Methods: From March 2013 - December 2014 a total of 295 percutaneous ultrasound guided biopsies from 287 patients with a suspected malignant renal lesion were performed at our institution. All cases were reviewed in PACS by (RR) and lesions presenting...... with a cystic change were re-evaluated and re-categorized after the Bosniak classification system. The re-evaluation and re-categorization was performed in consensus by a junior radiologist (RR) and an uro-radiological expert (OG). Results: Biopsies from eighteen Bosniak 2F cystic lesions were pathologically...... analyzed and three (17%) proved to be malignant. Biopsies from seventeen Bosniak 3 cystic lesions were pathologically analyzed and five (29%) were found to be malignant. Conclusion: Our results reveal a considerable malignancy rate among both Bosniak 2F and 3 cystic renal lesions. Biopsy seems...

  9. Prostate biopsy

    Science.gov (United States)

    ... give the cells a grade called a Gleason score . This helps predict how fast the cancer will ... TRUS); Stereotactic transperineal prostate biopsy (STPB) Images Male reproductive anatomy References Babayan RK, Katz MH. Biopsy prophylaxis, ...

  10. Differentiation of Prostatitis and Prostate Cancer by Using Diffusion-weighted MR Imaging and MR-guided Biopsy at 3 T

    NARCIS (Netherlands)

    Nagel, K.N.A.; Schouten, M.G.; Hambrock, T.; Litjens, G.J.S.; Hoeks, C.M.A.; Haken, B.T.; Barentsz, J.O.; Futterer, J.J.

    2013-01-01

    Purpose:To determine if prostatitis and prostate cancer (PCa) can be distinguished by using apparent diffusion coefficients (ADCs) on magnetic resonance (MR) images, with specimens obtained at MR-guided biopsy as the standard of reference.Materials and Methods:The need for institutional review board

  11. Role of axillary sentinel lymph node biopsy in patients with pure ductal carcinoma in situ of the breast

    International Nuclear Information System (INIS)

    Zavagno, Giorgio; Capitanio, Giovanni; Ballarin, Andrea; Pierobon, Maria Elena; Marconato, Giorgia; Nitti, Donato; Carcoforo, Paolo; Marconato, Renato; Franchini, Zeno; Scalco, Giuliano; Burelli, Paolo; Pietrarota, Paolo; Lise, Mario; Mencarelli, Roberto

    2005-01-01

    Sentinel lymph node (SLN) biopsy is an effective tool for axillary staging in patients with invasive breast cancer. This procedure has been recently proposed as part of the treatment for patients with ductal carcinoma in situ (DCIS), because cases of undetected invasive foci and nodal metastases occasionally occur. However, the indications for SLN biopsy in DCIS patients are controversial. The aim of the present study was therefore to assess the incidence of SLN metastases in a series of patients with a diagnosis of pure DCIS. A retrospective evaluation was made of a series of 102 patients who underwent SLN biopsy, and had a final histologic diagnosis of pure DCIS. Patients with microinvasion were excluded from the analysis. The patients were operated on in five Institutions between 1999 and 2004. Subdermal or subareolar injection of 30–50 MBq of 99 m-Tc colloidal albumin was used for SLN identification. All sentinel nodes were evaluated with serial sectioning, haematoxylin and eosin staining, and immunohistochemical analysis for cytocheratin. Only one patient (0.98%) was SLN positive. The primary tumour was a small micropapillary intermediate-grade DCIS and the SLN harboured a micrometastasis. At pathologic revision of the specimen, no detectable focus of microinvasion was found. Our findings indicate that SLN metastases in pure DCIS are a very rare occurrence. SLN biopsy should not therefore be routinely performed in patients who undergo resection for DCIS. SLN mapping can be performed, as a second operation, in cases in which an invasive component is identified in the specimen. Only DCIS patients who require a mastectomy should have SLN biopsy performed at the time of breast operation, since in these cases subsequent node mapping is not feasible

  12. Prostate needle biopsies: interobserver variation and clinical consequences of histopathological re-evaluation

    DEFF Research Database (Denmark)

    Berg, Kasper Drimer; Toft, Birgitte Grønkaer; Røder, Martin Andreas

    2011-01-01

    Histopathological grading of prostate cancer (PCa) is associated with significant interobserver variability. This, as well as clinical consequences of histopathological re-evaluation, was investigated. In 350 patients, histopathological re-evaluations of prostate biopsies were compared with primary...... pathology reports and with histopathology of the radical prostatectomy specimen. The consequences of re-evaluation for clinical workup and treatment of patients according to local algorithms were determined. For Gleason score (GS), complete agreement between primary report and re-evaluation was found in 76.......9%. The cancers were assessed with higher GS at re-evaluation in 25.0% of patients in cases with primary GS = 6, while scores were devaluated in 3.0% and 10.3% of the patients with primary GS = 7 and = 8, respectively. Strategies for clinical evaluation and treatment were changed as a result of the biopsy re...

  13. Percutaneous needle biopsy in diagnosis and identification of causative organisms in cases of suspected vertebral osteomyelitis

    International Nuclear Information System (INIS)

    Sehn, Jennifer K.; Gilula, Louis A.

    2012-01-01

    Background: Biopsy with demonstration of the infectious organism is the gold standard for diagnosing spondylodiscitis. The purpose of this study is to evaluate the positive culture rate of image-guided percutaneous biopsy in cases of radiologically suspected and unsuspected spinal osteomyelitis and to assess the role of pathology in diagnosis. Methods: With IRB approval and in compliance with HIPAA regulations, the charts of patients undergoing 323 consecutive image-guided percutaneous spinal biopsies performed by one musculoskeletal radiology department between January 2001 and March 2007 were reviewed. Image guidance was via fluoroscopy or computed tomography. Radiological and clinical suspicion, cultures, and pathology were assessed and compared to previously published reports. Results: In 92 cases radiographically and clinically consistent with infection (high probability of infection), 28 specimens yielded positive cultures (30.4%). Positive cultures resulted from 5 of 31 cases (16.1%) radiographically indeterminate for infection (intermediate probability of infection versus tumor). When radiographically not suggestive of infection (low probability of infection, i.e. suspicious for tumor), 10 of 200 cultures were positive (5.0%). From 113 cases sent to pathology with an intermediate or high suspicion for infection, 63 were histopathologically diagnosed as such (55.8%). Cultures were positive in 19 of those 63 cases (30.2%). Culture and/or pathology was positive in 73 (64.6%) of the 113 cases. There were no significant differences in rates of positive culture or pathology by vertebral region (p = 0.51, p = 0.81). The most frequently identified organisms were Staphylococcus aureus (13) and coagulase negative staphylococci (13). Conclusions: Our results suggest that the positive culture rate of percutaneous spinal biopsy specimens is 30.4% with radiographically high probability for infection, which is lower than previously published. Infection may also be present

  14. Retrospective review of pediatric oral lesions from a dental school biopsy service.

    Science.gov (United States)

    Shah, Suhani K; Le, Mary C; Carpenter, William M

    2009-01-01

    This report presents a review of the results from 5457 biopsies of patients, 0-16 years of age, received over 15 years at the University of the Pacific School of Dentistry (Pacific Oral and Maxillofacial Pathology Laboratory). To carry out the largest and most up to date U.S. survey of oral specimens from children. The computerized data was retrieved and compiled for age and diagnoses. The lesions were divided by the MIND classification system into 1) Metabolic 2) Inflammatory 3) Neoplastic and 4) Developmental. Inflammatory lesions formed the largest group of biopsies (2758, 51%) followed by Developmental conditions (1928, 35%) and Neoplasms (734, 13%). Dentigerous cysts were the most common lesions, followed by the mucous retention phenomenon (mucocele). The 15 most frequently occurring lesions accounted for 80% of all biopsies. Eight malignancies and 22 benign aggressive tumors were also included. 1. Pathoses increase with age. 2. Results from our study are similar to most of the other studies. 3. More serious pathoses occur in some countries where there is limited access to care, resulting in patients seeking care only when symptomatic. 4. Oral malignancies are rare, but as with any malignancy, early diagnosis renders a more favorable prognosis.

  15. La biopsie prostatique

    OpenAIRE

    DJEDOUI, MERIEM

    2013-01-01

    La preuve d'un cancer de la prostate est apportée par la biopsie prostatique. Malheureusement, une biopsie négative, bien que rassurante, ne suffit pas à exclure un noyau cancéreux à côté duquel l'aiguille est passée. L'urologue peut être amené à proposer une nouvelle biopsie, en augmentant, s'il le faut, le nombre de prélèvements de tissu prostatique. Ayant connu Le but d'une biopsie prostatique, le patient pourrait maintenant décider d'entrer dans d'autres alternatives qui...

  16. CT-guided biopsy of pulmonary lesions : a comparison of diagnostic accuracy and complication rate between automated gun biopsy and fine needle aspiration biopsy

    International Nuclear Information System (INIS)

    Kim, Keon Woo; Kang, Duk Sik

    1998-01-01

    The purpose of this study is to compare the efficacy and safety of CT-guided automated gun biopsy with those of fine needle aspiration biopsy of pulmonary lesions. Under CT guidance, we performed automated gu biopsies in 115 cases of 109 patients and fine needle aspiration biopsies in 119 cases of 108 patients with pulmonary lesions. Between the two methods, we compared the diagnostic rate, diagnostic accuracy and frequency of compilations according to the depth and diameter of pulmonary lesions. The overall diagnostic rates of automated gun biopsy and fine needle aspiration biopsy were 76.5 % (88/115) and 64.7 % (77/119) respectively. There was a significant statistical difference (p=0.048), especially in the case of malignant lesions less than 3 cm (p=0.027) and more than 6 cm in maximal diameter (p=0.008), and in the lesions located from 1 cm to less than 3 cm from the pleural (p=0.030), as seen on CT. There was no significant statistical difference in the frequency of complications. Automated gun biopsy of pulmonary lesions under CT guidance is safe, with complications rate comparable to those of fine needle aspiration biopsy. A higher overall diagnostic rate can be achieved by automated gun biopsy than by fine needle aspiration biopsy. For the diagnosis of pulmonary lesions under CT guidance, automated gun biopsy is therefore a more useful procedure than fine needle aspiration biopsy. (author). 24 refs., 3 tabs

  17. Ultrasound-guided diagnostic breast biopsy methodology: retrospective comparison of the 8-gauge vacuum-assisted biopsy approach versus the spring-loaded 14-gauge core biopsy approach

    Science.gov (United States)

    2011-01-01

    Background Ultrasound-guided diagnostic breast biopsy technology represents the current standard of care for the evaluation of indeterminate and suspicious lesions seen on diagnostic breast ultrasound. Yet, there remains much debate as to which particular method of ultrasound-guided diagnostic breast biopsy provides the most accurate and optimal diagnostic information. The aim of the current study was to compare and contrast the 8-gauge vacuum-assisted biopsy approach and the spring-loaded 14-gauge core biopsy approach. Methods A retrospective analysis was done of all ultrasound-guided diagnostic breast biopsy procedures performed by either the 8-gauge vacuum-assisted biopsy approach or the spring-loaded 14-gauge core biopsy approach by a single surgeon from July 2001 through June 2009. Results Among 1443 ultrasound-guided diagnostic breast biopsy procedures performed, 724 (50.2%) were by the 8-gauge vacuum-assisted biopsy technique and 719 (49.8%) were by the spring-loaded 14-gauge core biopsy technique. The total number of false negative cases (i.e., benign findings instead of invasive breast carcinoma) was significantly greater (P = 0.008) in the spring-loaded 14-gauge core biopsy group (8/681, 1.2%) as compared to in the 8-gauge vacuum-assisted biopsy group (0/652, 0%), with an overall false negative rate of 2.1% (8/386) for the spring-loaded 14-gauge core biopsy group as compared to 0% (0/148) for the 8-gauge vacuum-assisted biopsy group. Significantly more (P guided diagnostic breast biopsy procedure. Significantly more (P guided diagnostic breast biopsy procedure. Conclusions In appropriately selected cases, the 8-gauge vacuum-assisted biopsy approach appears to be advantageous to the spring-loaded 14-gauge core biopsy approach for providing the most accurate and optimal diagnostic information. PMID:21835024

  18. Association of Parathyroid Gland Biopsy Excision Technique With Ex Vivo Radiation Counts During Radioguided Parathyroid Surgery.

    Science.gov (United States)

    Hinson, Andrew M; Lawson, Bradley R; Franco, Aime T; Stack, Brendan C

    2017-06-01

    Parathyroid biopsy represents a means for normal and hyperfunctional glands to be distinguished intraoperatively. However, no data exist to guide surgeons regarding how much of a parathyroid gland must be biopsied to satisfy the 20% rule. To quantify the relative proportion of a hyperfunctional parathyroid gland that must be evaluated with the gamma probe to satisfy the 20% rule. A retrospective review of surgical data for 24 consecutive patients (16 women, 18 men; mean [SD] age, 66.6 [10] years; range, 51-83 years) who underwent surgery for primary hyperparathyroidism between May and October, 2015, in a tertieary academic medical center. Extirpated parathyroid glands were sectioned into parallel or pie-shaped biopsies and evaluated ex vivo with a gamma probe to determine what percentage of a hyperfunctional gland must be sampled to meet the Norman 20% rule. The hypothesis was formulated during data collection. In total, 253 ex vivo biopsy specimens were obtained from 33 surgically removed parathyroid glands. Parathyroid biopsies satisfied the 20% rule with an accuracy that depended on the relative proportion of the parent gland represented: half or more (96.6%; 95% CI, 91.7%-100.0%), a quarter to one-half (87.0%; 95% CI, 79.3%-94.7%), less than a quarter (63.6%; 95% CI, 54.5%-72.8%). When less than a quarter of the gland was removed, pie-shaped biopsies were more likely to satisfy the 20% rule compared with parallel biopsies of the same weight (78.4% vs 56.2%; absolute difference, 22.2%; 95% CI, 4.7%-39.7%). Unless half of a parathyroid gland is biopsied during radioguided parathyroidectomy, the 20% rule cannot reliably rule out the presence of a hyperfunctional parathyroid lesion. Pie-shaped biopsies originating from the center of the gland are associated with a lower rate of false-negative results compared with peripheral biopsies of similar size. Pie-shaped biopsies and biopsy of half or more of each nonexcised parathyroid gland for ex vivo counts may increase

  19. Usefulness of transrectal ultrasound-guided 12 core biopsy method in patients with clinically suspected prostate cancer

    International Nuclear Information System (INIS)

    Kwon, Se Hwan; Lim, Joo Won; Park, Seong Jin; Ko, Young Tae; Kim, Yoon Wha

    2000-01-01

    To evaluate the improvement of prostate cancer detection provided by transrectal ultrasound (TRUS)-guided 12 core biopsy method compared with sextant biopsy method. Between June 1997 and February 1999, 29 patients with pathologically proven prostate cancer in 124 patients who underwent TRUS-guided 12 core biopsy method were evaluated. They had abnormal findings in prostate specific antigen (PSA), digital rectal examination (DRE) or TRUS findings. The prostate was diffusely enlarged in all patients on DRE findings and in 15 cases (15/29, 52%), hard nodule was palpated. The average of PSA and prostate specific antigen density (PSAD) is 229.33 ng/ml (1-2280) and 9.14 ng/ml/cm 3 (0.048-142.5), respectively, 12 transrectal biopsy, including 2 transition zones, was performed in both lobe, 6 biopsies were located in both base, middle and apex. Then 2 biopsies were inserted between 3 biopsies in both peripheral zone and 2 biopsies were performed in both transition zone. Each specimen was pathologically examined. The results of pathology were compared with method 1 and 2, respectively. We defined the method 1 and 2 as different sextant biopsy method. The method 1 is that cores are taken from both base, middle and apex and method 2 is that cores are taken from both base, apex and transition zone. TRUS findings were analyzed by two radiologists. Of the 29 patients with prostate cancer, 3 (10%) had carcinomas only in the additional regions as compared with method. When compared with method 2,2 (7.0%) had carcinomas only in the additional regions. 2 patients were same in both cases. TRUS findings were abnormal in 21 cases in all patients whose 12 biopsy method was not helpful. 12 biopsy method was helpful in 2/8 (25%) whose TRUS findings were non-specific and 1/21 (4.8%) whose TRUS findings were abnormal. Small low echoic lesion was seen in one patients whose 12 biopsy method was helpful, but cancer was found in other area. TRUS-guided 12 core biopsy method may be superior to

  20. Relative quantification of PIK3CA gene expression level in fine-needle aspiration biopsy thyroid specimens collected from patients with papillary thyroid carcinoma and non-toxic goitre by real-time RT-PCR

    Directory of Open Access Journals (Sweden)

    Wojciechowska-Durczyńska Katarzyna

    2010-08-01

    Full Text Available Abstract Background Recent studies have shown that the phosphatidylinositol 3-kinase (PI3K signaling pathway is important regulator of many cellular events, including apoptosis, proliferation and motility. PI3K pathway alterations (PIK3CA gene mutations and/or amplification have been observed in various human tumours. In the majority of diagnosed cases, mutations are localized in one of the three "hot spots" in the gene, responsible for coding catalytic subunit α of class I PI3K (PIK3CA. Mutations and amplification of PIK3CA gene are characteristic for thyroid cancer, as well. Methods The aim of our study was to examine a gene expression level of PIK3CA in fine-needle aspiration biopsy (FNAB thyroid specimens in two types of thyroid lesions, papillary thyroid carcinoma (PTC and non-toxic goitre (NTG. Following conventional cytological examination, 42 thyroid FNAB specimens, received from patients with PTC (n = 20 and NTG (n = 22, were quantitatively evaluated regarding PIK3CA expression level by real-time PCR in the ABI PRISM® 7500 Sequence Detection System. Results Significantly higher expression level (RQ of PIK3CA in PTC group has been noted in comparison with NTG group (p Conclusion These observations may suggest role of PIK3CA alterations in PTC carcinogenesis.

  1. Hypoxia marker labeling in tumor biopsies: quantification of labeling variation and criteria for biopsy sectioning

    International Nuclear Information System (INIS)

    Thrall, Donald E.; Rosner, Gary L.; Azuma, Chieko; McEntee, Margaret C.; Raleigh, James A.

    1997-01-01

    Background and purpose: The error associated with using biopsy-based methods for assessing parameters reflective of the tumor microenvironment depends on the variability in distribution of the parameter throughout the tumor and the biopsy sample. Some attention has been given to intratumoral distribution of parameters, but little attention has been given to their intrabiopsy distribution. We evaluated the intrabiopsy distribution of CCI-103F, a 2-nitroimidazole hypoxia marker. Materials and methods: The hypoxia marker CCI-103F was studied in dogs bearing spontaneous solid tumors. Two biopsies were taken from each of seven tumors, for a total of 14 biopsies. Biopsies were serially sectioned and four to six contiguous slides from each 100-150 μm of the biopsy were used to formulate the best estimate of CCI-103F labeled area throughout the biopsy sample. One, two or four slides were then randomly selected from each biopsy and the labeled area, based on this limited sample, was compared to the estimate obtained from counting all available slides. Random sampling of slides was repeated 1000 times for each biopsy sample. Results: CCI-103F labeling variance throughout the biopsy decreased as the estimated overall labeled area in the biopsy decreased. The error associated with estimating the overall labeled area in a biopsy from a randomly selected subset of slides decreased as the number of slides increased, and as the overall labeled area in the biopsy decreased. No minimally labeled biopsy was classified as unlabeled based on limited sampling. Conclusion: With regard to CCI-103F labeling, quantification of the labeled area in four randomly selected slides from a biopsy can provide, in most biopsies, an estimate of the labeled area in the biopsy within an absolute range of ±0.05

  2. Comparative study of decomposable and indecomposable biopsy needle in lung puncture biopsy

    International Nuclear Information System (INIS)

    Wang Bo; Sheng Zhanxin; Wen Yamin; Zhang Liping; Wen Zongqiu

    2007-01-01

    Objective: To contrast the clinical practice characteristics with decomposable and indecomposable biopsy needle in the CT-guided lung puncture biopsy. Methods: 50 patients with lung tumour carried on puncture biopsy under the CT guidance were divided in two groups randomly: Group A (25 examples): using the indecomposable BioPinceTM biopsy needle; Group B(25 examples): using the decomposable Precisa or Vitesse biopsy needle. The puncture biopsy organization quantity, the first time puncture success rate, the pathological diagnosis result and the incidence of puncture complication were compared in two groups. Results: More striped structures were gained obviously in group A than in group B: 24/25 and 11/25 respectively (P>0.05), The pathological diagnosis 'serious extrusion amoebocyte and nature undetermined' only occurred in group B. But the first time puncture success rate was lower in group A than in B: 52%(13/25) and 80%(20/25) respectively (P>0.05), The incidence of hemorrhage and pneumothorax in group A was higher slightly: 84% and 72%, 16% and 4% respectively (P>0.05). Conclusion: The indecomposable needle (BioPinceTM) was better in lung puncture biopsy, but the lower first time puncture success rate also increases the risk of operation and complication in some degree because of the structure of the needle. On the contrary, decomposable needle (the Precisa or the Vitesse) was not the best choice in lung puncture biopsy. But it had the original superiority, especially regarding the special patient such as patient with small tumour, thin thoracic wall, bad physique for its nimble operation. It is essential for us to use the two different types of biopsy needle rationally to enhance the level of CT-guided lung puncture biopsy. (authors)

  3. Value of Tropheryma whipplei quantitative polymerase chain reaction assay for the diagnosis of Whipple disease: usefulness of saliva and stool specimens for first-line screening.

    Science.gov (United States)

    Fenollar, Florence; Laouira, Sonia; Lepidi, Hubert; Rolain, Jean-Marc; Raoult, Didier

    2008-09-01

    Whipple disease (WD) is a chronic infectious disease caused by Tropheryma whipplei. WD DNA has been found in stool and saliva specimens from patients and asymptomatic carriers. A total of 4418 samples that were sent to our center for determination of WD were tested by a T. whipplei-specific quantitative polymerase chain reaction (PCR) based on repetitive sequences. Definite WD was diagnosed in 71 patients, including 55 patients with classic WD (defined by positive results of periodic acid-Schiff staining and/or specific immunohistochemistry of small-bowel biopsy specimens) and 16 patients with localized WD (including patients with endocarditis, neurologic infection, and uveitis). Of the persons without WD, 2.3% had stool specimens positive for T. whipplei by PCR and 0.2% had saliva specimens positive for T. whipplei by PCR. Diagnosis of WD was likely in patients with positive results of both PCR of saliva specimens and PCR of stool specimens (positive predictive value, 95.2%). When the bacterial load was >10(4) colony-forming units per g of stool, the positive predictive value was 100%. A negative result of PCR of a saliva or stool specimen had a negative predictive value of 99.2% for classic WD. For localized WD, positive results of both PCR of saliva specimens and PCR of stool specimens had a sensitivity of 58% (compared with 94% for classic WD). The positive predictive value of testing of blood, cerebrospinal fluid, and urine specimens was 100% for each, and the positive predictive value for testing of duodenal biopsy specimens was 97.5%. T. whipplei-specific quantitative PCR of saliva and stool specimens should be performed as first-line noninvasive screening for WD. When the results for both types of specimens are positive, diagnosis of classic WD should be highly suspected, especially if a high bacterial load is detected. Because PCR of saliva and stool specimens lacks sensitivity for determination of localized WD, invasive samples should be tested on the

  4. Diagnostic efficacy of ultrasound-guided core-needle biopsy of peripheral lymph nodes in sarcoidosis.

    Science.gov (United States)

    Boussouar, S; Medjhoul, A; Bernaudin, J F; Tayebjee, O; Soussan, M; Uzunhan, Y; Nunes, H; Kambouchner, M; Martin, A; Valeyre, D; Brillet, P Y

    2015-09-14

    Core-needle biopsy guided by ultrasound can be performed for investigating peripheral lymph node (PLN). The aim of this study was to determine the efficacy of this technique in sarcoidosis. Retrospective review of files of all patients in the database of the radiology department of Avicenne university hospital who underwent PLN biopsies guided by ultrasound from January 2008 to June 2011 (n=292). Cases with either granulomas at histology with the procedure or with a final diagnosis of sarcoidosis were included in the study. The histological specimens were adequate in 282 out of 292 cases (96%) showing non-caseating granulomas in 22 cases (n=20 patients with a final diagnosis of sarcoidosis and n=2 patients with tuberculosis). After reviewing clinical files of the 282 patient, 22 were confirmed to have sarcoidosis, at initial presentation (n=19) or later during flare-up or relapse (n=3) with only 2 patients having no granuloma on PLN biopsy. PLN were palpable in 18 cases and only detected by (18F)FDG-PET/CT showing increased PLN uptake in 4 cases. The sensitivity and specificity of adequate biopsy were 91 and 99% and the positive and negative predictive values were 91 and 99%, respectively. Core-needle biopsy guided by ultrasound has a high efficacy for evidencing granulomas in sarcoidosis patients with PLN involvement either clinically palpable or in the presence of (18F)FDG-PET/CT uptake.

  5. Abdominal wall fat pad biopsy

    Science.gov (United States)

    Amyloidosis - abdominal wall fat pad biopsy; Abdominal wall biopsy; Biopsy - abdominal wall fat pad ... is the most common method of taking an abdominal wall fat pad biopsy . The health care provider cleans the ...

  6. Screening for Helicobacter pylori in Idiopathic Pulmonary Fibrosis Lung Biopsies.

    Science.gov (United States)

    Kreuter, Michael; Kirsten, Detlef; Bahmer, Thomas; Penzel, Roland; Claussen, Martin; Ehlers-Tenenbaum, Svenja; Muley, Thomas; Palmowski, Karin; Eichinger, Monika; Leider, Marta; Herth, Felix J F; Rabe, Klaus F; Bittmann, Iris; Warth, Arne

    2016-01-01

    Increasing evidence suggests a role of gastro-oesophageal reflux (GER) in idiopathic pulmonary fibrosis (IPF) pathogenesis. Recently, an association between serum Helicobacter pylori (HP) antibody positivity and more severe disease was described, but HP has not been directly analysed in lung tissue so far. To investigate the presence of HP in the lung tissue of IPF patients. Two tertiary interstitial lung disease care centre databases were screened for available lung biopsy material from IPF patients. Clinical and radiological data, including presence of GER and antiacid medication, were evaluated. HP-specific PCR was carried out on the IPF lung biopsy specimens. A total of 39 IPF patients were included, of whom 85% were male. The patients' median age was 66 years, their vital capacity was 79% predicted, and their diffusing capacity for carbon monoxide was 53% predicted. In all, 82% of the lung biopsies were surgical and 18% transbronchial. Comorbidities were GER disease in 23% (n = 9), sleep apnoea in 13% (n = 5) and hiatal hernia in 38% of the cases (n = 15). Proton pump inhibitors were prescribed at the time of biopsy in 21% of the cases (n = 9). After a median follow-up of 25 months (range 6-69), there were 1 death, 1 lung transplantation and 8 acute exacerbations without relevant differences between the GER and non-GER subgroups. HP DNA was not detected in any of the lung tissue samples. The fact that no HP DNA was detected in the lung tissues calls into question the proposed relevance of HP to the direct pathogenesis of IPF. © 2015 S. Karger AG, Basel.

  7. The clinical relevance of plasma CD147/basigin in biopsy-proven kidney diseases.

    Science.gov (United States)

    Mori, Yoshiko; Masuda, Tomohiro; Kosugi, Tomoki; Yoshioka, Tomoki; Hori, Mayuko; Nagaya, Hiroshi; Maeda, Kayaho; Sato, Yuka; Kojima, Hiroshi; Kato, Noritoshi; Ishimoto, Takuji; Katsuno, Takayuki; Yuzawa, Yukio; Kadomatsu, Kenji; Maruyama, Shoichi

    2017-12-12

    Precise understanding of kidney disease activity is needed to design therapeutic strategies. CD147/basigin is involved in the pathogenesis of acute kidney injury and renal fibrosis through inflammatory cell infiltration. The present study examined the clinical relevance of CD147 in biopsy-proven kidney diseases that lead to the progression of chronic kidney disease. Kidney biopsy specimens and plasma and urine samples were obtained from patients with kidney diseases, including IgA nephropathy (IgAN), Henoch-Schönlein purpura nephritis (HSPN), diabetic kidney disease (DKD), focal segmental glomerulosclerosis (FSGS), and membranous nephropathy (MN), who underwent renal biopsy between 2011 and 2014. Plasma and urinary CD147 levels were measured and evaluated for their ability to reflect histological features. Disease activity of IgAN tissues was evaluated according to the Oxford classification and the Japanese histological grading system. In biopsy tissues, CD147 induction was detected in injured lesions representing renal inflammation. Plasma CD147 values correlated with eGFR in patients with inflammation-related kidney diseases such as IgAN, HSPN, and DKD. Particularly in IgAN patients, plasma CD147 levels were correlated with injured regions comprising more than 50% of glomeruli or with tubular atrophy/interstitial injury in biopsy tissues. Proteinuria showed a closer correlation with urinary values of CD147 and L-FABP. Of note, plasma and urinary CD147 levels showed a strong correlation with eGFR or proteinuria, respectively, only in DKD patients. Evaluation of plasma and urinary CD147 levels might provide key insights for the understanding of the activity of various kidney diseases.

  8. BEM-based simulation of lung respiratory deformation for CT-guided biopsy.

    Science.gov (United States)

    Chen, Dong; Chen, Weisheng; Huang, Lipeng; Feng, Xuegang; Peters, Terry; Gu, Lixu

    2017-09-01

    Accurate and real-time prediction of the lung and lung tumor deformation during respiration are important considerations when performing a peripheral biopsy procedure. However, most existing work focused on offline whole lung simulation using 4D image data, which is not applicable in real-time image-guided biopsy with limited image resources. In this paper, we propose a patient-specific biomechanical model based on the boundary element method (BEM) computed from CT images to estimate the respiration motion of local target lesion region, vessel tree and lung surface for the real-time biopsy guidance. This approach applies pre-computation of various BEM parameters to facilitate the requirement for real-time lung motion simulation. The resulting boundary condition at end inspiratory phase is obtained using a nonparametric discrete registration with convex optimization, and the simulation of the internal tissue is achieved by applying a tetrahedron-based interpolation method depend on expert-determined feature points on the vessel tree model. A reference needle is tracked to update the simulated lung motion during biopsy guidance. We evaluate the model by applying it for respiratory motion estimations of ten patients. The average symmetric surface distance (ASSD) and the mean target registration error (TRE) are employed to evaluate the proposed model. Results reveal that it is possible to predict the lung motion with ASSD of [Formula: see text] mm and a mean TRE of [Formula: see text] mm at largest over the entire respiratory cycle. In the CT-/electromagnetic-guided biopsy experiment, the whole process was assisted by our BEM model and final puncture errors in two studies were 3.1 and 2.0 mm, respectively. The experiment results reveal that both the accuracy of simulation and real-time performance meet the demands of clinical biopsy guidance.

  9. Percutaneous CT-guided needle biopsies of musculoskeletal tumors: a 5-year analysis of non-diagnostic biopsies

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Connie Y.; Huang, Ambrose J.; Bredella, Miriam A.; Torriani, Martin; Rosenthal, Daniel I. [Massachusetts General Hospital, Division of Musculoskeletal Imaging and Intervention, Department of Radiology, Boston, MA (United States); Halpern, Elkan F. [Massachusetts General Hospital, Institute for Technology Assessment, Department of Radiology, Boston, MA (United States); Springfield, Dempsey S. [Massachusetts General Hospital, Department of Orthopedics, Boston, MA (United States)

    2015-12-15

    To study non-diagnostic CT-guided musculoskeletal biopsies and take steps to minimize them. Specifically we asked: (1) What malignant diagnoses have a higher non-diagnostic rate? (2) What factors of a non-diagnostic biopsy may warrant more aggressive pursuit? (3) Do intra-procedural frozen pathology (FP) or point-of-care (POC) cytology reduce the non-diagnostic biopsy rate ?This study was IRB-approved and HIPAA-compliant. We retrospectively reviewed 963 consecutive CT-guided musculoskeletal biopsies. We categorized pathology results as malignant, benign, or non-diagnostic and recorded use of FP or POC cytology. Initial biopsy indication, final diagnosis, method of obtaining the final diagnosis of non-diagnostic biopsies, age of the patient, and years of biopsy attending experience were recorded. Groups were compared using Pearson's χ{sup 2} test or Fisher's exact test. In all, 140 of 963 (15 %) biopsies were non-diagnostic. Lymphoma resulted in more non-diagnostic biopsies (P < 0.0001). While 67% of non-diagnostic biopsies yielded benign diagnoses, 33% yielded malignant diagnoses. Patients whose percutaneous biopsy was indicated due to the clinical context without malignancy history almost always generated benign results (96 %). Whereas 56% of biopsies whose indication was an imaging finding of a treatable lesion were malignant, 20% of biopsies whose indication was a history of malignancy were malignant. There was no statistically significant difference in the nondiagnostic biopsy rates of pediatric versus adult patients (P = 0.8) and of biopsy attendings with fewer versus more years of experience (P = 0.5). The non-diagnostic rates of biopsies with FP (8 %), POC cytology (25 %), or neither (24 %) were significantly different (P < 0.0001). Lymphoma is the malignant diagnosis most likely to result in a non-diagnostic biopsy. If the clinical and radiologic suspicion for malignancy is high, repeat biopsy is warranted. If the clinical context suggests a

  10. Percutaneous CT-guided needle biopsies of musculoskeletal tumors: a 5-year analysis of non-diagnostic biopsies

    International Nuclear Information System (INIS)

    Chang, Connie Y.; Huang, Ambrose J.; Bredella, Miriam A.; Torriani, Martin; Rosenthal, Daniel I.; Halpern, Elkan F.; Springfield, Dempsey S.

    2015-01-01

    To study non-diagnostic CT-guided musculoskeletal biopsies and take steps to minimize them. Specifically we asked: (1) What malignant diagnoses have a higher non-diagnostic rate? (2) What factors of a non-diagnostic biopsy may warrant more aggressive pursuit? (3) Do intra-procedural frozen pathology (FP) or point-of-care (POC) cytology reduce the non-diagnostic biopsy rate ?This study was IRB-approved and HIPAA-compliant. We retrospectively reviewed 963 consecutive CT-guided musculoskeletal biopsies. We categorized pathology results as malignant, benign, or non-diagnostic and recorded use of FP or POC cytology. Initial biopsy indication, final diagnosis, method of obtaining the final diagnosis of non-diagnostic biopsies, age of the patient, and years of biopsy attending experience were recorded. Groups were compared using Pearson's χ 2 test or Fisher's exact test. In all, 140 of 963 (15 %) biopsies were non-diagnostic. Lymphoma resulted in more non-diagnostic biopsies (P < 0.0001). While 67% of non-diagnostic biopsies yielded benign diagnoses, 33% yielded malignant diagnoses. Patients whose percutaneous biopsy was indicated due to the clinical context without malignancy history almost always generated benign results (96 %). Whereas 56% of biopsies whose indication was an imaging finding of a treatable lesion were malignant, 20% of biopsies whose indication was a history of malignancy were malignant. There was no statistically significant difference in the nondiagnostic biopsy rates of pediatric versus adult patients (P = 0.8) and of biopsy attendings with fewer versus more years of experience (P = 0.5). The non-diagnostic rates of biopsies with FP (8 %), POC cytology (25 %), or neither (24 %) were significantly different (P < 0.0001). Lymphoma is the malignant diagnosis most likely to result in a non-diagnostic biopsy. If the clinical and radiologic suspicion for malignancy is high, repeat biopsy is warranted. If the clinical context suggests a benign

  11. Detection of early lung cancer lesions in surgical resections and in bronchial and transbronchial biopsies

    International Nuclear Information System (INIS)

    Rott, T.; Jerse, M.; Tercelj, M.; Erzen, J.

    2006-01-01

    Background. Overall bad prognosis of lung cancer is mostly due to too late detection of early lung cancer, which may be treated with good success. Therefore, different diagnostic methods are developing for more efficient detection of early lung cancer: besides modern radiological, bronchoscopic methods with additional fluorescence techniques, quantitative cytological investigations, also histological and molecular investigations are included. Histology may reveal early preinvasive lung cancer lesions, associated early during multistep lung carcinogenesis with molecular genetic changes. Patients and methods. Preinvasive epithelial lung cancer lesions we searched in two groups of patients. In the first group of 316 patients from the period March 2003 - August 2006, 498 bronchial and transbronchial biopsies were examined for squamous metaplasia and dysplasia, carcinoma in situ, and invasive tumours. In the second group of 238 patients from the period January 2004 - August 2006, resected primary lung tumours were analysed for preinvasive and invasive neuroendocrine tumours and atypical adenomatous hyperplasia. Results. The most frequent changes in bronchial and transbronchial biopsies were squamous metaplasia (46.5%), simple or goblet cell hyperplasia of the bronchial epithelium (44.3%), malignant tumours (20.66%) and squamous dysplasia (16.1%), but rare carcinoma in situ (0.63%). Diffuse idiopathic pulmonary neuroendocrine cell hyperplasia was found in 15 (6.3%) cases in the vicinity of 238 resected lung cancer specimens, carcinoid in 12 patients (5%), and mostly combined large cell neuroendocrine cancer in 21 patients (8.8%). Atypical adenomatous hyperplasia was found in 2 patients. Conclusions. Classical histological analysis should be focused on detection of early preinvasive epithelial lung cancer lesions. Additional available molecular investigations may reveal gradual genetic changes characteristic for a series of the preinvasive epithelial histological changes

  12. Early prostate cancer antigen expression in predicting presence of prostate cancer in men with histologically negative biopsies.

    Science.gov (United States)

    Hansel, D E; DeMarzo, A M; Platz, E A; Jadallah, S; Hicks, J; Epstein, J I; Partin, A W; Netto, G J

    2007-05-01

    Early prostate cancer antigen is a nuclear matrix protein that was recently shown to be expressed in prostate adenocarcinoma and adjacent benign tissue. Previous studies have demonstrated early prostate cancer antigen expression in benign prostate tissue up to 5 years before a diagnosis of prostate carcinoma, suggesting that early prostate cancer antigen could be used as a potential predictive marker. We evaluated early prostate cancer antigen expression by immunohistochemistry using a polyclonal antibody (Onconome Inc., Seattle, Washington) on benign biopsies from 98 patients. Biopsies were obtained from 4 groups that included 39 patients with first time negative biopsy (group 1), 24 patients with persistently negative biopsies (group 2), 8 patients with initially negative biopsies who were subsequently diagnosed with prostate carcinoma (group 3) and negative biopsies obtained from 27 cases where other concurrent biopsies contained prostate carcinoma (group 4). Early prostate cancer antigen staining was assessed by 2 of the authors who were blind to the group of the examined sections. Staining intensity (range 0 to 3) and extent (range 1 to 3) scores were assigned. The presence of intensity 3 staining in any of the blocks of a biopsy specimen was considered as positive for early prostate cancer antigen for the primary outcome in the statistical analysis. In addition, as secondary outcomes we evaluated the data using the proportion of blocks with intensity 3 early prostate cancer antigen staining, the mean of the product of staining intensity and staining extent of all blocks within a biopsy, and the mean of the product of intensity 3 staining and extent. Primary outcome analysis revealed the proportion of early prostate cancer antigen positivity to be highest in group 3 (6 of 8, 75%) and lowest in group 2 (7 of 24, 29%, p=0.04 for differences among groups). A relatively higher than expected proportion of early prostate cancer antigen positivity was present in

  13. Diagnostic Ability of Percutaneous Needle Biopsy Immediately After Radiofrequency Ablation for Malignant Lung Tumors: An Initial Experience

    Energy Technology Data Exchange (ETDEWEB)

    Hasegawa, Takaaki, E-mail: t-hasegawa@aichi-cc.jp [Aichi Cancer Center Hospital, Department of Diagnostic and Interventional Radiology (Japan); Kondo, Chiaki [Aichi Cancer Center Hospital, Department of Pathology and Molecular Diagnosis (Japan); Sato, Yozo; Inaba, Yoshitaka; Yamaura, Hidekazu; Kato, Mina; Murata, Shinichi; Onoda, Yui [Aichi Cancer Center Hospital, Department of Diagnostic and Interventional Radiology (Japan); Kuroda, Hiroaki; Sakao, Yukinori [Aichi Cancer Center Hospital, Department of Thoracic Surgery (Japan); Yatabe, Yasushi [Aichi Cancer Center Hospital, Department of Pathology and Molecular Diagnosis (Japan)

    2016-08-15

    PurposeTo evaluate the safety and diagnostic ability of percutaneous needle biopsy performed immediately after lung radiofrequency ablation (RFA).Materials and MethodsFrom May 2013 to April 2014, percutaneous needle biopsy was performed immediately after RFA for 3 patients (2 men and 1 woman, aged 57–76 years) who had lung tumors measuring 1.3–2.6 cm in diameter. All patients had prior history of malignancy, and all tumors were radiologically diagnosed as malignant. Obtained specimens were pathologically classified using standard hematoxylin and eosin staining.ResultsWe completed three planned sessions of RFA followed by percutaneous needle biopsy, all of which obtained tumor tissue that could be pathologically diagnosed. Two tumors were metastatic from renal clear cell carcinoma and rectal adenocarcinoma, respectively; one tumor was primary lung adenocarcinoma. There was no death or major complication related to the procedures. Although pneumothorax occurred in two patients, these resolved without the need for aspiration or chest tube placement. Tumor seeding was not observed, but 21 months after the procedure, one case developed local tumor progression that was treated by additional RFA.ConclusionPathologic diagnosis was possible by needle biopsy immediately after RFA for lung tumors. This technique may reduce the risks and efforts of performing biopsy and RFA on separate occasions.

  14. Targeted MRI-guided prostate biopsy: are two biopsy cores per MRI-lesion required?

    Energy Technology Data Exchange (ETDEWEB)

    Schimmoeller, L.; Quentin, M.; Blondin, D.; Dietzel, F.; Schleich, C.; Thomas, C.; Antoch, G. [University Dusseldorf, Medical Faculty, Department of Diagnostic and Interventional Radiology, Dusseldorf (Germany); Hiester, A.; Rabenalt, R.; Albers, P.; Arsov, C. [University Dusseldorf, Medical Faculty, Department of Urology, Dusseldorf (Germany); Gabbert, H.E. [University Dusseldorf, Medical Faculty, Department of Pathology, Dusseldorf (Germany)

    2016-11-15

    This study evaluates the feasibility of performing less than two core biopsies per MRI-lesion when performing targeted MR-guided in-bore prostate biopsy. Retrospectively evaluated were 1545 biopsy cores of 774 intraprostatic lesions (two cores per lesion) in 290 patients (66 ± 7.8 years; median PSA 8.2 ng/ml) regarding prostate cancer (PCa) detection, Gleason score, and tumor infiltration of the first (FBC) compared to the second biopsy core (SBC). Biopsies were acquired under in-bore MR-guidance. For the biopsy cores, 491 were PCa positive, 239 of 774 (31 %) were FBC and 252 of 771 (33 %) were SBC (p = 0.4). Patient PCa detection rate based on the FBC vs. SBC were 46 % vs. 48 % (p = 0.6). For clinically significant PCa (Gleason score ≥4 + 3 = 7) the detection rate was 18 % for both, FBC and SBC (p = 0.9). Six hundred and eighty-seven SBC (89 %) showed no histologic difference. On the lesion level, 40 SBC detected PCa with negative FBC (7.5 %). Twenty SBC showed a Gleason upgrade from 3 + 3 = 6 to ≥3 + 4 = 7 (2.6 %) and 4 to ≥4 + 3 = 7 (0.5 %). The benefit of a second targeted biopsy core per suspicious MRI-lesion is likely minor, especially regarding PCa detection rate and significant Gleason upgrading. Therefore, a further reduction of biopsy cores is reasonable when performing a targeted MR-guided in-bore prostate biopsy. (orig.)

  15. Targeted MRI-guided prostate biopsy: are two biopsy cores per MRI-lesion required?

    International Nuclear Information System (INIS)

    Schimmoeller, L.; Quentin, M.; Blondin, D.; Dietzel, F.; Schleich, C.; Thomas, C.; Antoch, G.; Hiester, A.; Rabenalt, R.; Albers, P.; Arsov, C.; Gabbert, H.E.

    2016-01-01

    This study evaluates the feasibility of performing less than two core biopsies per MRI-lesion when performing targeted MR-guided in-bore prostate biopsy. Retrospectively evaluated were 1545 biopsy cores of 774 intraprostatic lesions (two cores per lesion) in 290 patients (66 ± 7.8 years; median PSA 8.2 ng/ml) regarding prostate cancer (PCa) detection, Gleason score, and tumor infiltration of the first (FBC) compared to the second biopsy core (SBC). Biopsies were acquired under in-bore MR-guidance. For the biopsy cores, 491 were PCa positive, 239 of 774 (31 %) were FBC and 252 of 771 (33 %) were SBC (p = 0.4). Patient PCa detection rate based on the FBC vs. SBC were 46 % vs. 48 % (p = 0.6). For clinically significant PCa (Gleason score ≥4 + 3 = 7) the detection rate was 18 % for both, FBC and SBC (p = 0.9). Six hundred and eighty-seven SBC (89 %) showed no histologic difference. On the lesion level, 40 SBC detected PCa with negative FBC (7.5 %). Twenty SBC showed a Gleason upgrade from 3 + 3 = 6 to ≥3 + 4 = 7 (2.6 %) and 4 to ≥4 + 3 = 7 (0.5 %). The benefit of a second targeted biopsy core per suspicious MRI-lesion is likely minor, especially regarding PCa detection rate and significant Gleason upgrading. Therefore, a further reduction of biopsy cores is reasonable when performing a targeted MR-guided in-bore prostate biopsy. (orig.)

  16. CT-guided transthoracic core needle biopsy for small pulmonary lesions: diagnostic performance and adequacy for molecular testing.

    Science.gov (United States)

    Tian, Panwen; Wang, Ye; Li, Lei; Zhou, Yongzhao; Luo, Wenxin; Li, Weimin

    2017-02-01

    Computed tomography (CT)-guided transthoracic needle biopsy is a well-established, minimally invasive diagnostic tool for pulmonary lesions. Few large studies have been conducted on the diagnostic performance and adequacy for molecular testing of transthoracic core needle biopsy (TCNB) for small pulmonary lesions. This study included CT-guided TCNB with 18-gauge cutting needles in 560 consecutive patients with small (≤3 cm) pulmonary lesions from January 2012 to January 2015. There were 323 males and 237 females, aged 51.8±12.7 years. The size of the pulmonary lesions was 1.8±0.6 cm. The sensitivity, specificity, accuracy and complications of the biopsies were investigated. The risk factors of diagnostic failure were assessed using univariate and multivariate analyses. The sample's adequacy for molecular testing of non-small cell lung cancer (NSCLC) was analyzed. The overall sensitivity, specificity, and accuracy for diagnosis of malignancy were 92.0% (311/338), 98.6% (219/222), and 94.6% (530/560), respectively. The incidence of bleeding complications was 22.9% (128/560), and the incidence of pneumothorax was 10.4% (58/560). Logistic multivariate regression analysis showed that the independent risk factors for diagnostic failure were a lesion size ≤1 cm [odds ratio (OR), 3.95; P=0.007], lower lobe lesions (OR, 2.83; P=0.001), and pneumothorax (OR, 1.98; P=0.004). Genetic analysis was successfully performed on 95.45% (168/176) of specimens diagnosed as NSCLC. At least 96.8% of samples with two or more passes from a lesion were sufficient for molecular testing. The diagnostic yield of small pulmonary lesions by CT-guided TCNB is high, and the procedure is relatively safe. A lesion size ≤1 cm, lower lobe lesions, and pneumothorax are independent risk factors for biopsy diagnostic failure. TCNB specimens could provide adequate tissues for molecular testing.

  17. Ex vivo MRI evaluation of prostate cancer: Localization and margin status prediction of prostate cancer in fresh radical prostatectomy specimens.

    Science.gov (United States)

    Heidkamp, Jan; Hoogenboom, Martijn; Kovacs, Iringo E; Veltien, Andor; Maat, Arie; Sedelaar, J P Michiel; Hulsbergen-van de Kaa, Christina A; Fütterer, Jurgen J

    2018-02-01

    To investigate the ability of high field ex vivo magnetic resonance imaging (MRI) to localize prostate cancer (PCa) and to predict the margin status in fresh radical prostatectomy (RP) specimens using histology as the reference standard. This Institutional Review Board (IRB)-approved study had written informed consent. Patients with biopsy-proved PCa and a diagnostic multiparametric 3T MRI examination of the prostate prior to undergoing RP were prospectively included. A custom-made container provided reference between the 7T ex vivo MRI obtained from fresh RP specimens and histological slicing. On ex vivo MRI, PCa was localized and the presence of positive surgical margins was determined in a double-reading session. These findings were compared with histological findings obtained from completely cut, whole-mount embedded, prostate specimens. In 12 RP specimens, histopathology revealed 36 PCa lesions, of which 17 (47%) and 20 (56%) were correlated with the ex vivo MRI in the first and second reading session, respectively. Nine of 12 (75%) index lesions were localized in the first session, in the second 10 of 12 (83%). Seven and 8 lesions of 11 lesions with Gleason score >6 and >0.5 cc were localized in the first and second session, respectively. In the first session none of the four histologically positive surgical margins (sensitivity 0%) and 9 of 13 negative margins (specificity 69%) were detected. In second session the sensitivity and specificity were 25% and 88%, respectively. Ex vivo MRI enabled accurate localization of PCa in fresh RP specimens, and the technique provided information on the margin status with high specificity. 1 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2018;47:439-448. © 2017 International Society for Magnetic Resonance in Medicine.

  18. CT-guided biopsies and drainage

    International Nuclear Information System (INIS)

    Scheppers, I.; Wollschlaeger, D.

    2011-01-01

    Following the implementation of computed tomography (CT) or ultrasound-guided biopsy of solid tumors and the puncture and drainage of liquid processes, the number of surgical open biopsies and curative operations for abscess drainage has declined. Such CT-guided interventions are performed in nearly every organ. Instead of aspiration biopsies, more and more core biopsies are being performed to allow histopathological evaluation and thus allowing targeted therapy. This article is intended to give a general overview of techniques, materials, indications and contraindications. Ultrasound-guided biopsies as well as large bore vacuum biopsies of the breast are not included in this review. (orig.) [de

  19. Effectiveness of combined use of imprint cytological and histological examination in CT-guided tissue-core biopsy

    International Nuclear Information System (INIS)

    Yamagami, Takuji; Yoshimatsu, Rika; Kajiwara, Kenji; Ishikawa, Masaki; Awai, Kazuo; Matsumoto, Tomohiro; Hasebe, Terumitsu; Kakizawa, Hideaki; Toyoda, Naoyuki

    2014-01-01

    This study evaluated the efficacy of the combination of imprint cytology and histology in tissue-core percutaneous biopsy under real-time computed tomography (CT) fluoroscopic guidance. Between October 2009 and June 2013, 156 percutaneous needle biopsies were performed in our institution. Those obtained by tissue-core biopsy underwent both imprint cytological and histological examinations routinely after touch imprint cytology was performed on site to evaluate the samples' sufficiency for cytological and pathological examination. Final diagnosis was confirmed by independent surgical pathology, independent culture results or clinical follow-up. Rates of adequate specimens and precise diagnosis, by combined cytological and histological examination were 100 % (156/156) and 96.2 % (150/156), by cytology 94.4 % (152/156) and 83.3 % (130/156) and by histology 99.3 % (155/156) and 92.3 % (144/156). Precise diagnosis was achieved by combined examinations in 94.7 % (89/94) of thoracic lesions, 97.6 % (40/41) of musculoskeletal lesions, and 100 % (21/21) of abdominal, pelvic and retroperitoneal lesions. In all 104 lesions diagnosed as malignant by CT-guided biopsy and in 30 of 52 diagnosed as benign, specific cell types could be proved by combined examinations. Combined imprint cytology and histology performed after on-site touch imprint cytological evaluation improved the diagnostic ability of CT fluoroscopically guided biopsy. (orig.)

  20. Effectiveness of combined use of imprint cytological and histological examination in CT-guided tissue-core biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Yamagami, Takuji; Yoshimatsu, Rika; Kajiwara, Kenji; Ishikawa, Masaki; Awai, Kazuo [Hiroshima University, Department of Diagnostic Radiology, Institute and Graduate School of Biomedical Sciences, Minami-Ku, Hiroshima (Japan); Matsumoto, Tomohiro; Hasebe, Terumitsu [Tokai University Hachioji Hospital, Tokai University School of Medicine, Department of Radiology, Hachioji, Tokyo (Japan); Kakizawa, Hideaki [Hiroshima University, Department of Diagnostic Radiology, Institute and Graduate School of Biomedical Sciences, Minami-Ku, Hiroshima (Japan); Hiroshima Red Cross Hospital and Atomic-bomb Survivors Hospital, Department of Diagnostic Radiology, Naka-Ku, Hiroshima (Japan); Toyoda, Naoyuki [Hiroshima University, Department of Diagnostic Radiology, Institute and Graduate School of Biomedical Sciences, Minami-Ku, Hiroshima (Japan); National Hospital Organisation Kure Medical Centre, Department of Diagnostic Radiology, Kure, Hiroshima (Japan)

    2014-05-15

    This study evaluated the efficacy of the combination of imprint cytology and histology in tissue-core percutaneous biopsy under real-time computed tomography (CT) fluoroscopic guidance. Between October 2009 and June 2013, 156 percutaneous needle biopsies were performed in our institution. Those obtained by tissue-core biopsy underwent both imprint cytological and histological examinations routinely after touch imprint cytology was performed on site to evaluate the samples' sufficiency for cytological and pathological examination. Final diagnosis was confirmed by independent surgical pathology, independent culture results or clinical follow-up. Rates of adequate specimens and precise diagnosis, by combined cytological and histological examination were 100 % (156/156) and 96.2 % (150/156), by cytology 94.4 % (152/156) and 83.3 % (130/156) and by histology 99.3 % (155/156) and 92.3 % (144/156). Precise diagnosis was achieved by combined examinations in 94.7 % (89/94) of thoracic lesions, 97.6 % (40/41) of musculoskeletal lesions, and 100 % (21/21) of abdominal, pelvic and retroperitoneal lesions. In all 104 lesions diagnosed as malignant by CT-guided biopsy and in 30 of 52 diagnosed as benign, specific cell types could be proved by combined examinations. Combined imprint cytology and histology performed after on-site touch imprint cytological evaluation improved the diagnostic ability of CT fluoroscopically guided biopsy. (orig.)

  1. CT-guided needle biopsy in the diagnosis of lung adenocarcinoma accompanied by extranodal marginal zone lymphoma of mucosa-associated lymphoid tissue: a rare combination.

    Science.gov (United States)

    Tian, Panwen; Wang, Ye; Wan, Chun; Shen, Yongchun; Wen, Fuqiang

    2015-01-01

    We represent a rare case of lung adenocarcinoma accompanied by extranodal marginal zone lymphoma of mucosa-associated lymphoid tissue (MALT). The patient was a 66-year-old male presented with 1 month history of recurrent cough and hemoptysis. Chest CT showed solitary ground-glass opacity (GGO) in the upper lobe of the right lung and mediastinal lymph node enlargement in station 3p. A CT-guided transthoracic needle biopsy was performed. Tissue specimens of the GGO revealed a typical adenocarcinoma. Histopathologic diagnosis of mediastinal lymph node was extranodal marginal zone lymphoma of MALT. Because of its rarity, extranodal marginal zone lymphoma of MALT should be considered in the differential diagnosis when we encounter mediastinal lymphadenopathy in patients with lung adenocarcinoma.

  2. CT fluoroscopy-guided vs. multislice CT biopsy mode-guided lung biopsies: Accuracy, complications and radiation dose

    International Nuclear Information System (INIS)

    Prosch, Helmut; Stadler, Alfred; Schilling, Matthias; Bürklin, Sandra; Eisenhuber, Edith; Schober, Ewald; Mostbeck, Gerhard

    2012-01-01

    Background: The aim of this retrospective study was to compare the diagnostic accuracy, the frequency of complications, the duration of the interventions and the radiation doses of CT fluoroscopy (CTF) guided biopsies of lung lesions with those of multislice CT (MS-CT) biopsy mode-guided biopsies. Methods: Data and images from 124 consecutive patients undergoing CTF-guided lung biopsy (group A) and 132 MS-CT-biopsy mode-guided lung biopsy (group B) were reviewed. CTF-guided biopsies were performed on a Siemens Emotion 6 CT scanner with intermittent or continuous CT-fluoroscopy, MS-CT biopsy mode-guided biopsies were performed on a Siemens Emotion 16 CT scanner. All biopsies were performed with a coaxial needle technique. Results: The two groups (A vs. B) did not differ significantly regarding sensitivity (95.5% vs. 95.9%), specificity (96.7% vs. 95.5%), negative predictive value (87.9% vs. 84%) or positive predictive value (98.8% vs. 98.9%). Pneumothorax was observed in 30.0% and 32.5% of the patients, respectively. Chest tube placement was necessary in 4% (group A) and 13% (group B) of the patients. The duration of the intervention was significantly longer in group A (median 37 min vs. 32 min, p = 0.04). The mean CT dose index (CTDI) was 422 in group A and 36.3 in group B (p < 0.001). Conclusion: Compared to CTF-guided biopsies, chest biopsies using the MS-CT biopsy mode show dramatically lower CTDI levels. Although the diagnostic yield of the procedures do not differ significantly, biopsies using the MS-CT-biopsy mode have a three-fold higher rate of chest tube placement.

  3. A retrospective study: correlation of histologic inflammation in biopsy specimens of Chinese men undergoing surgery for benign prostatic hyperplasia with serum prostate-specific antigen.

    Science.gov (United States)

    Song, Lingmin; Zhu, Yuchun; Han, Ping; Chen, Ni; Lin, Dao; Lai, Jianyu; Wei, Qiang

    2011-03-01

    To reveal the correlation between benign prostatic hyperplasia (BPH) histologic inflammation and serum prostate-specific antigen (sPSA) concentrations, and the possible mechanism. Patients underwent surgery at the Urology Department of West China Hospital of Sichuan University were retrospectively studied. Preoperative sPSA and transrectal ultrasonography were measured. According to the histopathological classification system for chronic prostatic inflammation proposed by the Chronic Prostatitis Collaborative Research Network (CPCRN) and the International Prostatitis Collaborative Network (IPCN), we classified the histologic sections of prostatic biopsy into glandular, periglandular, and stromal inflammation by the anatomical location of inflammatory infiltration. The glandular inflammation was graded according to the inflammatory aggressiveness. The periglandular and stromal inflammation were graded according to the inflammatory density. The correlation between histologic inflammation and sPSA was studied by a multiple regression model in conjunction with age and total prostatic volume. A total of 454 patients with exclusively BPH were analyzed. The periglandular inflammatory infiltration was the most common pattern (95.6%). Single regression analysis revealed that total prostatic volume, the aggressiveness of glandular inflammation, and the intensity of periglandular and stromal inflammation were correlated with sPSA. However, the multiple regression analysis revealed that only the total prostatic volume and the aggressiveness of glandular inflammation were correlated significantly with sPSA (R = .389, 0.289; P = .000). The aggressiveness of glandular inflammatory infiltration in BPH is a significant contributor to elevated sPSA levels. The theory of leakage may be the most reasonable mechanism to reveal the correlation morphologically. We should take inflammation into consideration when interpreting the abnormal elevating of sPSA levels. Copyright © 2011

  4. Salivary gland biopsy

    Science.gov (United States)

    ... also be performed to diagnose diseases such as Sjogren syndrome . How to Prepare for the Test There is ... few days after the biopsy. The biopsy for Sjogren syndrome requires an injection of the anesthetic in the ...

  5. Non-repeatable science: assessing the frequency of voucher specimen deposition reveals that most arthropod research cannot be verified

    Directory of Open Access Journals (Sweden)

    Shaun Turney

    2015-08-01

    Full Text Available Scientific findings need to be verifiable and grounded in repeatability. With specimen-level research this is in part achieved with the deposition of voucher specimens. These are labeled, curated, data-based specimens that have been deposited in a collection or museum, available for verification of the work and to ensure researchers are calling the same taxa by the same names. Voucher specimens themselves are the subject of research, from the discovery of new species by taxonomists to ecologists documenting historical records of invasive species. Our objective was to quantify the frequency of voucher specimen deposition in biodiversity and community ecology research through a survey of the peer-reviewed literature about arthropods, from 1989 until 2014. Overall rates of voucher deposition were alarmingly low, at under 25%. This rate increased significantly over time, with 35% of papers reporting on vouchers in 2014. Relative to the global mean, entomological research had a significantly higher rate of voucher deposition (46%, whereas researchers studying crustaceans deposited vouchers less than 6% of the time, significantly less than the mean. Researchers working in museums had a significantly higher frequency of voucher deposition. Our results suggest a significant culture shift about the process of vouchering specimens is required. There must be more education and mentoring about voucher specimens within laboratories and across different fields of study. Principal investigators and granting agencies need a proactive approach to ensuring specimen-level data are properly, long-term curated. Editorial boards and journals can also adopt policies to ensure papers are published only if explicit statements about the deposition of voucher specimens is provided. Although the gap is significant, achieving a higher rate of voucher specimen deposition is a worthy goal to ensure all research efforts are preserved for future generations.

  6. Non-repeatable science: assessing the frequency of voucher specimen deposition reveals that most arthropod research cannot be verified.

    Science.gov (United States)

    Turney, Shaun; Cameron, Elyssa R; Cloutier, Christopher A; Buddle, Christopher M

    2015-01-01

    Scientific findings need to be verifiable and grounded in repeatability. With specimen-level research this is in part achieved with the deposition of voucher specimens. These are labeled, curated, data-based specimens that have been deposited in a collection or museum, available for verification of the work and to ensure researchers are calling the same taxa by the same names. Voucher specimens themselves are the subject of research, from the discovery of new species by taxonomists to ecologists documenting historical records of invasive species. Our objective was to quantify the frequency of voucher specimen deposition in biodiversity and community ecology research through a survey of the peer-reviewed literature about arthropods, from 1989 until 2014. Overall rates of voucher deposition were alarmingly low, at under 25%. This rate increased significantly over time, with 35% of papers reporting on vouchers in 2014. Relative to the global mean, entomological research had a significantly higher rate of voucher deposition (46%), whereas researchers studying crustaceans deposited vouchers less than 6% of the time, significantly less than the mean. Researchers working in museums had a significantly higher frequency of voucher deposition. Our results suggest a significant culture shift about the process of vouchering specimens is required. There must be more education and mentoring about voucher specimens within laboratories and across different fields of study. Principal investigators and granting agencies need a proactive approach to ensuring specimen-level data are properly, long-term curated. Editorial boards and journals can also adopt policies to ensure papers are published only if explicit statements about the deposition of voucher specimens is provided. Although the gap is significant, achieving a higher rate of voucher specimen deposition is a worthy goal to ensure all research efforts are preserved for future generations.

  7. Ultrasound-guided fine needle aspiration versus core needle biopsy: comparison of post-biopsy hematoma rates and risk factors.

    Science.gov (United States)

    Chae, In Hye; Kim, Eun-Kyung; Moon, Hee Jung; Yoon, Jung Hyun; Park, Vivian Y; Kwak, Jin Young

    2017-07-01

    To compare post-biopsy hematoma rates between ultrasound guided-fine needle aspiration and ultrasound guided-core needle biopsy, and to investigate risk factors for post-biopsy hematoma. A total of 5304 thyroid nodules which underwent ultrasound guided biopsy were included in this retrospective study. We compared clinical and US features between patients with and without post-biopsy hematoma. Associations between these features and post-biopsy hematoma were analyzed. Post-biopsy hematoma rate was 0.8% (43/5121) for ultrasound guided-fine needle aspiration and 4.9% (9/183) for ultrasound guided-core needle biopsy (P core needle biopsy (9/179, 5.0%) than with ultrasound guided-fine needle aspiration (9/1138, 0.8%) (P core needle biopsy was the only significant risk factor for post-biopsy hematoma (adjusted Odds Ratio, 6.458, P core needle biopsy than in ultrasound guided-fine needle aspiration and ultrasound guided-core needle biopsy was the only independent factor of post-biopsy hematoma in thyroid nodules.

  8. CT-Guided Biopsy of Small Liver Lesions: Visibility, Artifacts, and Corresponding Diagnostic Accuracy

    International Nuclear Information System (INIS)

    Stattaus, Joerg; Kuehl, Hilmar; Ladd, Susanne; Schroeder, Tobias; Antoch, Gerald; Baba, Hideo A.; Barkhausen, Joerg; Forsting, Michael

    2007-01-01

    Purpose. Our study aimed to determine the visibility of small liver lesions during CT-guided biopsy and to assess the influence of lesion visibility on biopsy results. Material and Methods. Fifty patients underwent CT-guided core biopsy of small focal liver lesions (maximum diameter, 3 cm); 38 biopsies were performed using noncontrast CT, and the remaining 12 were contrast-enhanced. Visibility of all lesions was graded on a 4-point-scale (0 = not visible, 1 = poorly visible, 2 = sufficiently visible, 3 = excellently visible) before and during biopsy (with the needle placed adjacent to and within the target lesion). Results. Forty-three biopsies (86%) yielded diagnostic results, and seven biopsies were false-negative. In noncontrast biopsies, the rate of insufficiently visualized lesions (grades 0-1) increased significantly during the procedure, from 10.5% to 44.7%, due to needle artifacts. This resulted in more (17.6%) false-negative biopsy results compared to lesions with good visualization (4.8%), although this difference lacks statistical significance. Visualization impairment appeared more often with an intercostal or subcostal vs. an epigastric access and with a subcapsular vs. a central lesion location, respectively. With contrast-enhanced biopsy the visibility of hepatic lesions was only temporarily improved, with a risk of complete obscuration in the late phase. Conclusion. In conclusion, visibility of small liver lesions diminished significantly during CT-guided biopsy due to needle artifacts, with a fourfold increased rate of insufficiently visualized lesions and of false-negative histological results. Contrast enhancement did not reveal better results

  9. Optical biopsy of head and neck cancer using hyperspectral imaging and convolutional neural networks

    Science.gov (United States)

    Halicek, Martin; Little, James V.; Wang, Xu; Patel, Mihir; Griffith, Christopher C.; El-Deiry, Mark W.; Chen, Amy Y.; Fei, Baowei

    2018-02-01

    Successful outcomes of surgical cancer resection necessitate negative, cancer-free surgical margins. Currently, tissue samples are sent to pathology for diagnostic confirmation. Hyperspectral imaging (HSI) is an emerging, non-contact optical imaging technique. A reliable optical method could serve to diagnose and biopsy specimens in real-time. Using convolutional neural networks (CNNs) as a tissue classifier, we developed a method to use HSI to perform an optical biopsy of ex-vivo surgical specimens, collected from 21 patients undergoing surgical cancer resection. Training and testing on samples from different patients, the CNN can distinguish squamous cell carcinoma (SCCa) from normal aerodigestive tract tissues with an area under the curve (AUC) of 0.82, 81% accuracy, 81% sensitivity, and 80% specificity. Additionally, normal oral tissues can be sub-classified into epithelium, muscle, and glandular mucosa using a decision tree method, with an average AUC of 0.94, 90% accuracy, 93% sensitivity, and 89% specificity. After separately training on thyroid tissue, the CNN differentiates between thyroid carcinoma and normal thyroid with an AUC of 0.95, 92% accuracy, 92% sensitivity, and 92% specificity. Moreover, the CNN can discriminate medullary thyroid carcinoma from benign multi-nodular goiter (MNG) with an AUC of 0.93, 87% accuracy, 88% sensitivity, and 85% specificity. Classical-type papillary thyroid carcinoma is differentiated from benign MNG with an AUC of 0.91, 86% accuracy, 86% sensitivity, and 86% specificity. Our preliminary results demonstrate that an HSI-based optical biopsy method using CNNs can provide multi-category diagnostic information for normal head-and-neck tissue, SCCa, and thyroid carcinomas. More patient data are needed in order to fully investigate the proposed technique to establish reliability and generalizability of the work.

  10. Corpus vitreum, retina og chorioidea biopsi

    DEFF Research Database (Denmark)

    Scherfig, Erik Christian Høegh

    2002-01-01

    oftalmology, biopsy, choroid, corpus vitreum, retina, malignant melanoma, biopsy technic, retinoblastoma......oftalmology, biopsy, choroid, corpus vitreum, retina, malignant melanoma, biopsy technic, retinoblastoma...

  11. A multicenter study of biopsied oral and maxillofacial lesions in a Brazilian pediatric population.

    Science.gov (United States)

    Silva, Leni Verônica de Oliveira; Arruda, José Alcides Almeida; Martelli, Stephanie Joana; Kato, Camila de Nazaré Alves de Oliveira; Nunes, Laiz Fernanda Mendes; Vasconcelos, Ana Carolina Uchoa; Tarquinio, Sandra Beatriz Chaves; Gomes, Ana Paula Neutzling; Gomez, Ricardo Santiago; Mesquita, Ricardo Alves; Silveira, Marcia Maria Fonseca da; Sobral, Ana Paula Veras

    2018-03-15

    The aim of this study was to investigate the prevalence of oral and maxillofacial lesions among children from representative regions of Brazil. A retrospective descriptive study was conducted. Biopsy records comprising the period from 2000 to 2015 were obtained from the archives of three Brazilian oral pathology referral centers. A total of 32,506 biopsy specimens were analyzed, and specimens from 1,706 children aged 0-12 years were selected. Gender, age, anatomical location and histopathological diagnosis were evaluated. Descriptive statistics was carried out. Likelihood ratio tests were used to evaluate the association between the categorical variables. The level of significance was set at 0.05. The post-hoc test was used to identify the subgroups that significantly differed from one another, and the Bonferroni correction was applied. A total of 1,706 oral and maxillofacial lesions were diagnosed in pediatric patients, including 51.9% girls. Oral mucocele was the most prevalent reactive/inflammatory lesion (64%). The most commonly affected sites were the lips (34.5%) and mandible (19.9%). A significant association was observed between age and the group of lesions of the oral cavity (p oral and maxillofacial lesions were frequent and showed wide diversity, with the prevalence of mucocele. Knowledge of oral lesions is important for pediatric dentists worldwide, since it provides accurate data for the diagnosis and oral health of children.

  12. C-arm cone-beam CT virtual navigation-guided percutaneous mediastinal mass biopsy: Diagnostic accuracy and complications

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyungjin [Seoul National University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Seoul National University Medical Research Center, Institute of Radiation Medicine, Seoul (Korea, Republic of); Aerospace Medical Group, Air Force Education and Training Command, Jinju (Korea, Republic of); Park, Chang Min; Goo, Jin Mo [Seoul National University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Seoul National University Medical Research Center, Institute of Radiation Medicine, Seoul (Korea, Republic of); Seoul National University, Cancer Research Institute, Seoul (Korea, Republic of); Lee, Sang Min [Seoul National University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Seoul National University Medical Research Center, Institute of Radiation Medicine, Seoul (Korea, Republic of)

    2015-12-15

    To assess the usefulness of C-arm cone-beam computed tomography (CBCT) virtual navigation-guided percutaneous mediastinal mass biopsy in terms of diagnostic accuracy and complication rates. Seventy-eight CBCT virtual navigation-guided percutaneous mediastinal mass biopsies were performed in 75 patients (M:F, 38:37; mean age, 48.55 ± 18.76 years). The procedural details, diagnostic sensitivity, specificity, accuracy and complication rate were investigated. Mean lesion size was 6.80 ± 3.08 cm, skin-to-target distance was 3.67 ± 1.80 cm, core needle biopsy rate was 96.2 % (75/78), needle indwelling time was 9.29 ± 4.34 min, total procedure time was 13.26 ± 5.29 min, number of biopsy specimens obtained was 3.13 ± 1.02, number of CBCTs performed was 3.03 ± 0.68, rate of lesion border discrimination from abutting mediastinal structures on CBCT was 26.9 % (21/78), technical success rate was 100 % (78/78), estimated effective dose was 5.33 ± 4.99 mSv, and the dose area product was 12,723.68 ± 10,665.74 mGy.cm{sup 2}. Among the 78 biopsies, 69 were malignant, 7 were benign and 2 were indeterminate. Diagnostic sensitivity, specificity and accuracy for the diagnosis of malignancies were 97.1 % (67/69), 100 % (7/7) and 97.4 % (74/76), respectively, with a complication rate of 3.85 % (3/78), all of which were small pneumothoraces. CBCT virtual navigation-guided biopsy is a highly accurate and safe procedure for the evaluation of mediastinal lesions. (orig.)

  13. Biopsy - Multiple Languages

    Science.gov (United States)

    ... Biopsy - العربية (Arabic) Bilingual PDF Health Information Translations Breast Biopsy - العربية (Arabic) Bilingual PDF Health Information Translations Colposcopy - العربية (Arabic) Bilingual PDF ...

  14. Primary temporal region squamous cell carcinoma diagnosed by a superficial temporal artery biopsy

    DEFF Research Database (Denmark)

    Andersen, S A W; Kiss, K

    2015-01-01

    artery biopsy was performed. The histopathology revealed perineural invasion of squamous cell carcinoma (SCC). A thorough investigation revealed no other primary site for the SCC and the patient was treated with surgical excision. CONCLUSION: Malignancy is rarely found in superficial temporal artery...

  15. Cytology specimens offer an effective alternative to formalin-fixed tissue as demonstrated by novel automated detection for ALK break-apart FISH testing and immunohistochemistry in lung adenocarcinoma.

    Science.gov (United States)

    Rosenblum, Frida; Hutchinson, Lloyd M; Garver, Joann; Woda, Bruce; Cosar, Ediz; Kurian, Elizabeth M

    2014-11-01

    Minimally invasive sampling by cytology or core needle biopsy often provides an initial diagnosis for treatment in patients with lung nodules. From these limited specimens, multiple molecular studies are frequently requested. Current guidelines from the US Food and Drug Administration recommend using formalin-fixed paraffin-embedded tissue sections for the detection of anaplastic lymphoma kinase (ALK) gene rearrangement by fluorescence in situ hybridization (FISH). The authors compared alcohol-fixed and formalin-fixed cytology specimens using a novel automated detection for ALK rearrangements by FISH and immunohistochemistry (IHC). ALK FISH testing was performed on 129 lung adenocarcinomas from 71 cytology cases and 58 biopsy/resection specimens using Papanicolaou staining with integrated cytomorphology. IHC with the ALK D5F3 antibody was performed on cases with residual material (88 of 129 cases). The mean age of the patients was 66 years; there were 62 women and 67 men. ALK gene rearrangement was present in 4% of cytology specimens (3 of 71 specimens) and 7% of surgical specimens (4 of 58 specimens). FISH in 13 cases was technically unsuccessful. Of the 7 FISH-positive cases, only 2 cytology cases (4%) and 2 surgical cases (6%) were found to be positive with the ALK antibody, demonstrating 80% concordance. The one case found to be negative for ALK by IHC demonstrated a variant rearrangement of the ALK 2p23 gene locus by FISH. The results of the current study validate the usefulness of alcohol-fixed and/or formalin-fixed cytology specimens for ALK rearrangement by a novel automated FISH method. IHC using the D5F3 antibody for ALK is specific in this limited cohort. The authors also demonstrated that alcohol-fixed cytology specimens can be used for ALK rearrangement by automated FISH, alone or in conjunction with IHC. © 2014 American Cancer Society.

  16. Ultrasound-guided percutaneous renal biopsy with an automated biopsy gun in diffuse renal disease

    International Nuclear Information System (INIS)

    Kim, Ji Yang; Moon, Jeoung Mi; Park, Ji Hyun; Kwon, Jae Soo; Song, Ik Hoon; Kim, Sung Rok

    1994-01-01

    We evaluated the effectiveness and clinical usefulness of percutaneous renal biopsy by using automated biopsy gun under the real-time ultrasonographic guidance that was performed in 17 patients with diffuse renal disease. We retrospectively analysed the histopathological diagnosis and the patients' status after percutaneous renal biopsy.Adequate amount of tissue for the histologic diagnosis could be obtained in al patients. Histopathologic diagnosis included the minimal change nephrotic syndrome in 6 patients, the membrano proliferative glomerulonephritis in 4,the membranous glomerulonephritis in 2, the glomerulosclerosis in 2, Ig A nephropathy in 2, and the normal finding in 1. Significant complication occurred in only one patient who developed a transient loss of sensation at and around the biopsy site. In conclusion, automated biopsy gun was a very useful device in performing percutaneous biopsy for diffuse renal disease with a high success rate and a low complication rate

  17. Can EGFR mutation status be reliably determined in pre-operative needle biopsies from adenocarcinomas of the lung?

    DEFF Research Database (Denmark)

    Lindahl, Kim Hein; Sørensen, Flemming Brandt; Jonstrup, Søren Peter

    2015-01-01

    The identification of EGFR mutations in non-small-cell lung cancer is important for selecting patients, who may benefit from treatment with EGFR tyrosine kinase inhibitors. The analysis is usually performed on cytological aspirates and/or histological needle biopsies, representing a small fraction....... Moreover, several inconclusive results in the diagnostic biopsies reveal that attention must be paid on the suitability of pre-operative biopsies for EGFR mutation analysis....

  18. Fibroadenoma versus phyllodes tumor: distinguishing factors in patients diagnosed with fibroepithelial lesions after a core needle biopsy

    Science.gov (United States)

    Wiratkapun, Cholatip; Piyapan, Pawat; Lertsithichai, Panuwat; Larbcharoensub, Noppadol

    2014-01-01

    PURPOSE We aimed to identify factors that might help differentiate phyllodes tumors from fibroadenomas among cases in which a fibroepithelial breast lesion was diagnosed from core needle biopsy (CNB) under imaging guidance. MATERIALS AND METHODS A retrospective review was performed on 213 lesions in 200 patients who had undergone both CNB and excisional biopsy during a four-year period between 2008 and 2011. The final pathology revealed 173 fibroadenomas and 40 phyllodes tumors. The data, including patient characteristics, clinical presentation, and mammography, ultrasonography (US), and pathology findings were analyzed. RESULTS Upon univariable analysis, the factors that significantly helped to identify phyllodes tumors consisted of the presenting symptoms (palpable mass or breast pain), increased size on clinical examination, hyperdense mass on mammogram, and the following three US features: heterogeneous echo, presence of round cysts within the mass, and presence of clefts within the mass. The pathologist’s suggestion of a phyllodes tumor was also helpful. The factors that remained statistically significant upon multivariable analysis consisted of symptoms of breast pain, the presence of clefts on US, the presence of round cysts on US and the pathologist’s favoring of phyllodes tumors from a CNB specimen. CONCLUSION A multidisciplinary approach was needed to distinguish phyllodes tumors from fibroadenomas in patients who had undergone CNB. US findings (clefts and round cysts), suggestive pathological diagnoses, and clinical symptoms were all useful for the decision to surgically remove the fibroepithelial lesions diagnosed from CNB. PMID:24356293

  19. Efficacy of deep biopsy for subepithelial lesions in the upper gastrointestinal tract.

    Science.gov (United States)

    Vaicekauskas, Rolandas; Stanaitis, Juozas; Valantinas, Jonas

    2016-01-01

    Accurate diagnosis of subepithelial lesions (SELs) in the gastrointestinal tract depends on a variety of methods: endoscopy, endoscopic ultrasound and different types of biopsy. Making an error-free diagnosis is vital for the subsequent application of an appropriate treatment. To evaluate the efficacy of deep biopsy via the endoscopic submucosal dissection (ESD) technique for SELs in the upper gastrointestinal tract. It was a case series study. Deep biopsy via the ESD technique was completed in 38 patients between November 2012 and October 2014. Thirty-eight SELs in the upper gastrointestinal tract of varying size (very small ≤ 1 cm, small 1-2 cm and large ≥ 2 cm) by means of the ESD technique after an incision with an electrosurgical knife of the overlying layers and revealing a small part of the lesion were biopsied under direct endoscopic view. Deep biopsy via the ESD technique was diagnostic in 28 of 38 patients (73.3%; 95% CI: 59.7-89.7%). The diagnostic yield for SELs with a clear endophytic shape increased to 91.3%. An evident endophytic appearance of a subepithelial lesion, the mean number of biopsied samples (6.65 ±1.36) and the total size in length of all samples per case (19.88 ±8.07 mm) were the main criteria influencing the positiveness of deep biopsy in the diagnostic group compared to the nondiagnostic one (p = 0.001; p = 0.025; p = 0.008). Deep biopsy via the ESD technique is an effective and safe method for the diagnosis of SELs especially with a clear endophytic appearance in a large number of biopsied samples.

  20. Stereotactic core biopsy: Comparison of 11 gauge with 8 gauge vacuum assisted breast biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Venkataraman, Shambhavi, E-mail: svenkata@bidmc.harvard.edu [Department of Radiology, Beth Israel Deaconess Medical Center, 330 Brookline Avenue, Boston, MA 02215 (United States); Dialani, Vandana [Department of Radiology, Beth Israel Deaconess Medical Center, 330 Brookline Avenue, Boston, MA 02215 (United States); Gilmore, Hannah L. [Department of Pathology, UH Case Medical Center, 11100 Euclid Ave, Cleveland, OH 44106 (United States); Mehta, Tejas S. [Department of Radiology, Beth Israel Deaconess Medical Center, 330 Brookline Avenue, Boston, MA 02215 (United States)

    2012-10-15

    Purpose: The compare the performance and ability to obtain a correct diagnosis on needle biopsy between 11 gauge and 8 gauge vacuum assisted biopsy devices. Materials and methods: Hospital records of all consecutive stereotactic core biopsies performed over five years were retrospectively reviewed in compliance Health Insurance Portability and Accountability Act (HIPPA) policy and with approval from the hospital institutional review board (IRB). Pathology from core biopsy was compared with surgical pathology and/or imaging follow-up. A histological underestimation was defined if the surgical excision yielded a higher grade on pathology which changed management. Results: 828 needle core biopsies (47.5%, 393/828 with 11 gauge and 52.5%, 435/828 with 8 gauge) yielded 471 benign, 153 high risk and 204 malignant lesions. 30/193 (15.5%) 11 gauge lesions and 16/185 (8.6%) 8 gauge lesions demonstrated higher grade pathology on surgical excision. The difference in the rates of the number of correct diagnoses on core needle biopsy between 11 gauge (363/393, 92.4%) and 8 gauge (419/435, 96.3%) based on either surgical or clinical/imaging follow up and the difference in the number of discordant benign core biopsies between 11 (17/217, 7.8%) and 8 gauge (4/254, 1.6%) necessitating a surgical biopsy was significant (P = 0.013; P = 0.001). Although there were more underestimations with the 11 gauge (25/193, 13.0%) than 8 gauge (15/185, 8.1%) needle, this was not significant. Conclusion: Our study demonstrates improved performance and increased diagnostic ability of 8 gauge needle over 11 gauge in obtaining a correct diagnosis on needle biopsy.

  1. Endoscopic biopsies in Ussing chambers evaluated for studies of macromolecular permeability in the human colon.

    Science.gov (United States)

    Wallon, Conny; Braaf, Ylva; Wolving, Mats; Olaison, Gunnar; Söderholm, Johan D

    2005-05-01

    Studies of mucosal permeability to protein antigens in humans are limited to in vitro techniques. The use of surgical specimens for such studies has major shortcomings. Endoscopic biopsies in Ussing chambers have been introduced as a means of studying secretion and transepithelial permeability, but have not been evaluated for studies of protein antigen uptake in human intestine. Standard forceps biopsies from the sigmoid colon of 24 healthy volunteers were mounted in Ussing chambers with an exposed tissue area of 1.76 mm2. 51Cr-EDTA (paracellular probe) and horseradish peroxidase (HRP; 45 kDa protein antigen) were used as permeability markers. Mucosal permeability, electrophysiology, histology and energy contents of the biopsies were studied over time. To evaluate the ability of the technique to detect permeability changes, the mucosa was modulated with capric acid, a medium-chain fatty acid, known to affect tight junctions. In the Ussing chamber the mucosal biopsies were viable for 160 min with stable levels of ATP and lactate, and only minor changes in morphology. Steady-state permeability with low variability was seen for both markers during the 30-90 min period. Exposure to capric acid induced a rapid decrease in short-circuit current (Isc) and a slower reversible decrease in transepithelial resistance (TER), as well as an increased permeability to 51Cr-EDTA and HRP. Endoscopic biopsies of human colon are viable in Ussing chambers and are reliable tools for studies of mucosal permeability to protein antigens. The technique offers a broad potential for studies of mucosal function in the pathophysiology of human gastrointestinal diseases.

  2. Lobular neoplasia found on breast biopsy: marker of increased risk of malignancy or direct pre-cancerous lesion?

    Directory of Open Access Journals (Sweden)

    Jan Kornafel

    2011-10-01

    Full Text Available The aim of this study was to compare the imaging symptoms and microscopic findings in females with lobular neoplasia (LN found on biopsy. 1,478 women who underwent primary open biopsy or surgical excision after percutaneous biopsy were reviewed. In 24 of them (1.6%, LN was found. In four patients, excisional biopsy with hook-wire localization was done primarily due to the radial scar. In 20 females, surgical excision of BIRADS 4 lesion was performed because of the presence of LN in specimens from the vacuum-assisted or core-needle percutaneous biopsy. Postoperative pathologic findings were compared to the radiological symptoms. In 13 women, LN did not produce any radiological symptoms and was an additional histologic finding existing near the other lesion: fibroadenoma and radial scar. In none of these lesions was an invasive cancer noticed. In one single patient, ductal carcinoma in situ was observed in the other segment of the breast. Invasive ductal cancer developed in the contralateral breast in one patient. In 11 patients, LN was diagnosed due to radiological symptoms produced by itself. In this group, the invasive lobular cancer was found in seven lesions (64%. Our finding suggests that LN producing suspicious radiological symptoms can be a different biologic type of this lesion when compared asymptomatic LN diagnosed which is usually found on biopsy as additional microscopic pathology. Symptomatic LN is probably associated with a higher potential of malignant transformation. (Folia Histochemica et Cytobiologica 2011; Vol. 49, No. 3, pp. 417–424

  3. Intra-patient comparison of parietal pleural biopsies by rigid forceps, flexible forceps and cryoprobe obtained during medical thoracoscopy: a prospective series of 80 cases with pleural effusion.

    Science.gov (United States)

    Wurps, H; Schönfeld, N; Bauer, T T; Bock, M; Duve, C; Sauer, R; Mairinger, T; Griff, S

    2016-07-07

    There is only few data available on the use of cryotechnique during medical thoracoscopy. Medical thoracoscopy was performed in consecutive patients with pleural effusion. Prospectively, biopsies were taken by rigid forceps, flexible forceps and cryoprobe. Specimen size, depth and diagnostic yield were compared. 80 Patients were included. 408 biopsies were taken (205 rigid biopsies, 104 flexible biopsies, 99 cryobiopsies). Mean surface area of rigid biopsies was 22.6 ± 20.4 mm(2) (flexible biopsies: 7.1 ± 9.3 mm(2), cryobiopsies: 14.4 ± 12.8 mm(2)). Rigid biopsies were significantly larger than cryobiopsies (p < 0.001) and flexible biopsies (p < 0.001), crybiopsies were significantly larger than flexible biopsies (p < 0.01). A deep biopsy containing fatty tissue was harvested in 63 % of rigid biopsies (cryobiopsy: 49.5 % flexible biopsy: 39.5 %). In 79/80 cases (98.7 % 95 % CI cannot be calculated) a diagnosis was obtained by rigid biopsy (cryobiopsy: 73/80 cases (91.3 % 95 % CI 86.0 - 96.5 %), flexible biopsy: 74/80 cases (92.5 % 95 % CI 88.6 - 97.4 %)). Diagnostic yield achieved with cryobiopsies was inferior to the yield of rigid biopsies (Difference: 12.7 %), but non-inferior to flexible biopsies (Difference: 6.5 %). Cryobiopsies in medical thoracoscopy are safe with high diagnostic yield, non-inferior to flexible biopsies with increased tissue quantity and quality. Cryotechnique can develop an important role in medical thoracoscopy in the near future when rigid thoracoscopy is not available.

  4. Liquid biopsy in the diagnosis of HPV DNA in breast lesions.

    Science.gov (United States)

    Carolis, Sabrina De; Pellegrini, Alice; Santini, Donatella; Ceccarelli, Claudio; De Leo, Antonio; Alessandrini, Federica; Arienti, Chiara; Pignatta, Sara; Tesei, Anna; Mantovani, Vilma; Zamagni, Claudio; Taffurelli, Mario; Sansone, Pasquale; Bonafé, Massimiliano; Cricca, Monica

    2018-02-01

    HPV DNA has never been investigated in nipple discharges (ND) and serum-derived extracellular vesicles, although its presence has been reported in ductal lavage fluids and blood specimens. We analyzed 50 ND, 22 serum-derived extracellular vesicles as well as 51 pathologic breast tissues for the presence of 16 HPV DNA types. We show that the presence of HPV DNA in the ND is predictive of HPV DNA-positive breast lesions and that HPV DNA is more represented in intraductal papillomas. We also show the presence of HPV DNA in the serum-derived extracellular vesicles. Our data supports the use of liquid biopsy to detect HPV DNA in breast pathology.

  5. Direct measurement of catalase activity in living cells and tissue biopsies.

    Science.gov (United States)

    Scaglione, Christine N; Xu, Qijin; Ramanujan, V Krishnan

    2016-01-29

    Spatiotemporal regulation of enzyme-substrate interactions governs the decision-making steps in biological systems. Enzymes, being functional units of every living cell, contribute to the macromolecular stability of cell survival, proliferation and hence are vital windows to unraveling the biological complexity. Experimental measurements capturing this dynamics of enzyme-substrate interactions in real time add value to this understanding. Furthermore these measurements, upon validation in realistic biological specimens such as clinical biopsies - can further improve our capability in disease diagnostics and treatment monitoring. Towards this direction, we describe here a novel, high-sensitive measurement system for measuring diffusion-limited enzyme-substrate kinetics in real time. Using catalase (enzyme) and hydrogen peroxide (substrate) as the example pair, we demonstrate that this system is capable of direct measurement of catalase activity in vitro and the measured kinetics follows the classical Michaelis-Menten reaction kinetics. We further demonstrate the system performance by measuring catalase activity in living cells and in very small amounts of liver biopsies (down to 1 μg total protein). Catalase-specific enzyme activity is demonstrated by genetic and pharmacological tools. Finally we show the clinically-relevant diagnostic capability of our system by comparing the catalase activities in liver biopsies from young and old mouse (liver and serum) samples. We discuss the potential applicability of this system in clinical diagnostics as well as in intraoperative surgical settings. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Sentinel node biopsy before neoadjuvant chemotherapy spares breast cancer patients axillary lymph node dissection.

    Science.gov (United States)

    van Rijk, Maartje C; Nieweg, Omgo E; Rutgers, Emiel J T; Oldenburg, Hester S A; Olmos, Renato Valdés; Hoefnagel, Cornelis A; Kroon, Bin B R

    2006-04-01

    Neoadjuvant chemotherapy in breast cancer patients is a valuable method to determine the efficacy of chemotherapy and potentially downsize the primary tumor, which facilitates breast-conserving therapy. In 18 studies published about sentinel node biopsy after neoadjuvant chemotherapy, the sentinel node was identified in on average 89%, and the false-negative rate was on average 10%. Because of these mediocre results, no author dares to omit axillary clearance just yet. In our institute, sentinel lymph node biopsy is performed before neoadjuvant chemotherapy. The aim of this study was to evaluate our experience with this approach. Sentinel node biopsy was performed before neoadjuvant chemotherapy in 25 T2N0 patients by using lymphoscintigraphy, a gamma ray detection probe, and patent blue dye. Axillary lymph node dissection was performed after chemotherapy if the sentinel node contained metastases. Ten patients had a tumor-positive axillary sentinel node, and one patient had an involved lateral intramammary node. Four patients had additional involved nodes in the completion lymph node dissection specimen. The other 14 patients (56%) had a tumor-negative sentinel node and did not undergo axillary lymph node dissection. No recurrences have been observed after a median follow-up of 18 months. Fourteen (56%) of the 25 patients were spared axillary lymph node dissection when the sentinel node was found to be disease free. Performing sentinel node biopsy before neoadjuvant chemotherapy seems successful and reliable in patients with T2N0 breast cancer.

  7. [Safety management in pathology laboratory: from specimen handling to confirmation of reports].

    Science.gov (United States)

    Minato, Hiroshi; Nojima, Takayuki; Nakano, Mariko; Yamazaki, Michiko

    2011-03-01

    Medical errors in pathological diagnosis give a huge amount of physical and psychological damage to patients as well as medical staffs. We discussed here how to avoid medical errors in surgical pathology laboratory through our experience. Handling of surgical specimens and diagnosing process requires intensive labor and involves many steps. Each hospital reports many kinds of accidents or incidents, however, many laboratories share common problems and each process has its specific risk for the certain error. We analyzed the problems in each process and concentrated on avoiding misaccessioning, mislabeling, and misreporting. We have made several changes in our system, such as barcode labels, digital images of all specimens, putting specimens in embedding cassettes directly on the endoscopic biopsied specimens, and using a multitissue control block as controls in immunohistochemistry. Some problems are still left behind, but we have reduced the errors by decreasing the number of artificial operation as much as possible. A pathological system recognizing the status of read or unread the pathological reports by clinician are now underconstruction. We also discussed about quality assurance of diagnosis, cooperation with clinicians and other comedical staffs, and organization and method. In order to operate riskless work, it is important for all the medical staffs to have common awareness of the problems, keeping careful observations, and sharing all the information in common. Incorporation of an organizational management tool such as ISO 15189 and utilizing PDCA cycle is also helpful for safety management and quality improvement of the laboratory.

  8. CT-guided percutaneous spine biopsy in suspected infection or malignancy. A study of 214 patients

    Energy Technology Data Exchange (ETDEWEB)

    Rehm, J.; Veith, S.; Kauczor, H.U.; Weber, M.A. [Heidelberg Univ. (Germany). Inst. of Diagnostic and Interventional Radiology; Akbar, M. [Heidelberg Univ. (Germany). Dept. of Orthopaedic Surgery and Rehabilitation Medicine

    2016-12-15

    To retrospectively determine the effectiveness and accuracy of CT-guided percutaneous biopsy of malignant and inflammatory bone lesions of the spine and to assess the reliability of pre-biopsy CT and MRI. 214 patients with lesions of the spine, which were suspicious either for being malignant or inflammatory, underwent CT-guided biopsy for pathological and/or microbiological detection. Biopsy samples were sent for histological examination in 128/214 patients, for microbiological analysis in 17/214 patients and for both analyses in 69/214 patients. Retrospectively, the diagnostic accuracy and sensitivity/specificity of the pre-interventional imaging (CT and MRI) were determined. In addition, the influence of the biopsy on subsequent patient management was assessed. The accuracy was 94.4% for histopathological analysis and 97.7% for microbiological analysis. In 25% of cases the microbiological analysis revealed an underlying pathogen that was not significantly affected by pre-biopsy antibiotic therapy. The sensitivity/specificity of the pre-biopsy cross-sectional imaging concerning suspected malignancy was 69%/78%. For suspected infection, the sensitivity/specificity of pre-biopsy imaging was 81%/44%. In 52% of all cases, the biopsy result changed subsequent patient management. Percutaneous CT-guided spine biopsy is a useful and reliable diagnostic procedure to establish a definitive diagnosis but with a relatively low yield of microorganisms in the case of infection.

  9. CT-guided percutaneous spine biopsy in suspected infection or malignancy. A study of 214 patients

    International Nuclear Information System (INIS)

    Rehm, J.; Veith, S.; Kauczor, H.U.; Weber, M.A.; Akbar, M.

    2016-01-01

    To retrospectively determine the effectiveness and accuracy of CT-guided percutaneous biopsy of malignant and inflammatory bone lesions of the spine and to assess the reliability of pre-biopsy CT and MRI. 214 patients with lesions of the spine, which were suspicious either for being malignant or inflammatory, underwent CT-guided biopsy for pathological and/or microbiological detection. Biopsy samples were sent for histological examination in 128/214 patients, for microbiological analysis in 17/214 patients and for both analyses in 69/214 patients. Retrospectively, the diagnostic accuracy and sensitivity/specificity of the pre-interventional imaging (CT and MRI) were determined. In addition, the influence of the biopsy on subsequent patient management was assessed. The accuracy was 94.4% for histopathological analysis and 97.7% for microbiological analysis. In 25% of cases the microbiological analysis revealed an underlying pathogen that was not significantly affected by pre-biopsy antibiotic therapy. The sensitivity/specificity of the pre-biopsy cross-sectional imaging concerning suspected malignancy was 69%/78%. For suspected infection, the sensitivity/specificity of pre-biopsy imaging was 81%/44%. In 52% of all cases, the biopsy result changed subsequent patient management. Percutaneous CT-guided spine biopsy is a useful and reliable diagnostic procedure to establish a definitive diagnosis but with a relatively low yield of microorganisms in the case of infection.

  10. Percutaneous biopsy of a metastatic common iliac lymph node using hydrodissection and a semi-automated biopsy gun

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, Seong Yoon; Park, Byung Kwan [Dept. of Radiology, amsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2017-06-15

    Percutaneous biopsy is a less invasive technique for sampling the tissue than laparoscopic biopsy or exploratory laparotomy. However, it is difficult to perform biopsy of a deep-seated lesion because of the possibility of damage to the critical organs. Recently, we successfully performed CT-guided biopsy of a metastatic common iliac lymph node using hydrodissection and semi-automated biopsy devices. The purpose of this case report was to show how to perform hydrodissection and how to use a semi-automated gun for safe biopsy of a metastatic common iliac lymph node.

  11. Indications and results of renal biopsy in children: a 36-year experience.

    Science.gov (United States)

    Santangelo, Luisa; Netti, Giuseppe Stefano; Giordano, Paolo; Carbone, Vincenza; Martino, Marida; Torres, Diletta Domenica; Rossini, Michele; Di Palma, Anna Maria; Gesualdo, Loreto; Giordano, Mario

    2018-04-01

    This study was conducted to investigate retrospectively the indications for renal biopsy (RB) in native kidneys and to analyze pathological findings in a single tertiary pediatric hospital in Southern Italy for the last 36 years. All patients who underwent RB at our hospital from 1979 to 2014 were included. All renal tissue specimens were studied under light and immunofluorescent microscopy, while electron microscopy was performed only for specific clinical indications. The study group included 213 patients (female 43.2%) who underwent 225 percutaneous native kidney biopsies. Median age was 10.4 years (range 0.6-24 years). The most frequent indication for RB was nephrotic syndrome (44.4%), followed by proteinuria (27.6%), asymptomatic hematuria (17.3%) and acute kidney injury (9.8%). Gross hematuria appeared after biopsy in less than 5% of the patients, but none of them needed blood transfusion. Adequate renal tissue sample was obtained in 95.5% of the renal biopsies. Primary glomerulonephritis (GN) was the most common finding (61.4%), followed by secondary GN (21.4%), tubulointerstitial diseases (3.7%) and hereditary nephropathy (2.8%), while in 10.7% of the cases, normal renal tissues were found. According to histopathological diagnosis, the most common causes of primary GN were IgA nephropathy (20.9%), followed by minimal change disease (18.1%) and focal segmental glomerulosclerosis (11.6%). The epidemiology of glomerular disease in our single-center cohort is similar to that shown in other national and international reports. Moreover, our study shows that percutaneous ultrasound-guided RB is a safe, reliable and effective technique in children.

  12. Complications of percutaneous renal tumor biopsy: An analysis of 340 consecutive biopsies

    DEFF Research Database (Denmark)

    René Rasmussen, Lars; Loft, Martina; Høyer, Søren

    Purpose Ultrasound Guided Percutaneous Kidney Biopsy (UGPKB) plays a major role in diagnosis of renal tumours. There seems to be little consensus regarding post-biopsy observation period. We aim to identify complications in UGPKB among outpatients with a suspected malignant renal lesion as well...... as the timing of onset of these complications, helping to clarify the optimal observation period. Many studies in this field suggest a lower complication risk for outpatients compared to hospitalized patients. In the latter group, an observation period of 24h after biopsy is often recommended. Material...... discrepancy. Results As for one third of the patients, analysed up until now, we find a total of one major complication and a few minor, all arisen within less than 6 hours after biopsy. Conclusions Rates of both major and minor complications in UGPKB are very low suggesting a shorter observation period...

  13. Computerized determination of 3-D connectivity density in human iliac crest bone biopsies

    DEFF Research Database (Denmark)

    Thomsen, J.S.; Mosekilde, Li.; Barlach, J.

    1996-01-01

    Combining the physical disector principle with an algorithm for automatic non-linear alignment of disector pairs we have developed a software system for direct measurement of 3D connectivity densities in iliac crest bone biopsies. The method was applied to biopsies from 14 non-selected autopsy...... cases: 7 men (age range 20-84 yr) and 7 women (age range 20-86 yr). The study reveals decreases in both trabecular bone mass and connectivity density with age in women....

  14. The Clinical and Genomic Significance of Donor-Specific Antibody–Positive/C4d-Negative and Donor-Specific Antibody–Negative/C4d-Negative Transplant Glomerulopathy

    Science.gov (United States)

    Hayde, Nicole; Bao, Yi; Pullman, James; Ye, Bin; Calder, R. Brent; Chung, Monica; Schwartz, Daniel; Lubetzky, Michelle; Ajaimy, Maria; de Boccardo, Graciela

    2013-01-01

    Summary Background This study investigated the mechanisms involved in development of donor-specific antibody (DSA) and/or C4d-negative transplant glomerulopathy (TGP) by allograft gene expression profiles using microarrays. Design, Setting, Participants, & Measurements This cohort study was conducted in kidney transplant recipients. Patients were eligible for inclusion if they required a clinically indicated biopsy at any time point after their transplant. They were then classified according to their histopathology findings and DSA and C4d results. Eighteen chronic antibody-mediated rejection (CAMR), 14 DSA+/C4d− TGP, 25 DSA−/C4d− TGP, and 47 nonspecific interstitial fibrosis/tubular atrophy (IFTA) biopsy specimens were identified. In a subset of patients from the study population, biopsy specimens in each group and normal transplant kidney specimens were analyzed with Affymetrix Human Gene 1.0 ST Arrays. Results The mean sum score of glomerulitis and peritubular capillaritis increased from 0.28±0.78 in IFTA specimens to 0.75±0.85 in DSA−/C4d− TGP specimens, 1.71±1.49 in DSA+/C4d−/TGP specimens, and 2.11±1.74 in CAMR specimens (PTGP specimens (14.3%), and DSA−/C4d− TGP specimens (16%) (P=0.01). With use of microarrays, comparison of the gene expression profiles of DSA−/C4d− TGP specimens with glomerulitis + peritubular capillaritis scores > 0 to normal and IFTA biopsy specimens revealed higher expression of quantitative cytotoxic T cell–associated transcripts (QCAT). However, both CAMR and DSA+/C4d− TGP specimens had higher expression of not only QCAT but also IFN-γ and rejection-induced, constitutive macrophage-associated, natural killer cell–associated, and DSA-selective transcripts. Endothelial cell–associated transcript expression was upregulated only in CAMR biopsy specimens. Conclusions These results suggested that DSA+/C4d− TGP biopsy specimens may be classified as CAMR. In contrast, DSA−/C4d− TGP specimens showed

  15. The clinical and genomic significance of donor-specific antibody-positive/C4d-negative and donor-specific antibody-negative/C4d-negative transplant glomerulopathy.

    Science.gov (United States)

    Hayde, Nicole; Bao, Yi; Pullman, James; Ye, Bin; Calder, R Brent; Chung, Monica; Schwartz, Daniel; Lubetzky, Michelle; Ajaimy, Maria; de Boccardo, Graciela; Akalin, Enver

    2013-12-01

    This study investigated the mechanisms involved in development of donor-specific antibody (DSA) and/or C4d-negative transplant glomerulopathy (TGP) by allograft gene expression profiles using microarrays. This cohort study was conducted in kidney transplant recipients. Patients were eligible for inclusion if they required a clinically indicated biopsy at any time point after their transplant. They were then classified according to their histopathology findings and DSA and C4d results. Eighteen chronic antibody-mediated rejection (CAMR), 14 DSA+/C4d- TGP, 25 DSA-/C4d- TGP, and 47 nonspecific interstitial fibrosis/tubular atrophy (IFTA) biopsy specimens were identified. In a subset of patients from the study population, biopsy specimens in each group and normal transplant kidney specimens were analyzed with Affymetrix Human Gene 1.0 ST Arrays. The mean sum score of glomerulitis and peritubular capillaritis increased from 0.28±0.78 in IFTA specimens to 0.75±0.85 in DSA-/C4d- TGP specimens, 1.71±1.49 in DSA+/C4d-/TGP specimens, and 2.11±1.74 in CAMR specimens (PTGP specimens (14.3%), and DSA-/C4d- TGP specimens (16%) (P=0.01). With use of microarrays, comparison of the gene expression profiles of DSA-/C4d- TGP specimens with glomerulitis + peritubular capillaritis scores > 0 to normal and IFTA biopsy specimens revealed higher expression of quantitative cytotoxic T cell-associated transcripts (QCAT). However, both CAMR and DSA+/C4d- TGP specimens had higher expression of not only QCAT but also IFN-γ and rejection-induced, constitutive macrophage-associated, natural killer cell-associated, and DSA-selective transcripts. Endothelial cell-associated transcript expression was upregulated only in CAMR biopsy specimens. These results suggested that DSA+/C4d- TGP biopsy specimens may be classified as CAMR. In contrast, DSA-/C4d- TGP specimens showed increased cytotoxic T cell-associated transcripts, suggesting T cell activation as a mechanism of injury.

  16. The proportion of prostate biopsy tissue with Gleason pattern 4 or 5 predicts for biochemical and clinical outcome after radiotherapy for prostate cancer

    International Nuclear Information System (INIS)

    D'Ambrosio, David J.; Hanlon, Alexandra L.; Al-Saleem, Tahseen; Feigenberg, Steven J.; Horwitz, Eric M.; Uzzo, Robert G.; Pollack, Alan; Buyyounouski, Mark K.

    2007-01-01

    Purpose: To investigate the prognostic utility of the proportion of prostate biopsy tissue containing Gleason pattern 4 or 5 (GP4/5) after definitive radiotherapy (RT) for prostate cancer. Methods and Materials: A total of 568 patients with T1c-3 Nx/0 prostate cancer who received three-dimensional conformal RT alone between May 1989 and August 2001 were studied. There were 161 men with Gleason score 7-10 disease. The GP4/5 was defined as the percentage of biopsy tissue containing Gleason pattern 4 or 5. A Cox proportional hazards model was used for univariate and multivariate analyses (MVA) for biochemical failure (BF) (American Society of Therapeutic Radiology and Oncology definition) and distant metastasis (DM). A recursive partitioning analysis was done using the results of the MVA to identify a cutpoint for GP4/5. Results: The median follow-up was 46 (range, 13-114) months and median RT dose was 76 (range, 65-82) Gy. On MVA, increasing initial prostate-specific antigen (p = 0.0248) decreasing RT dose (continuous, p = 0.0022), T stage (T1/2 vs. T3) (p = 0.0136) and GP4/5 (continuous, p < 0.0001) were significant predictors of BF in a model also containing GS. GP4/5 was the only significant predictor of DM in the same model (p < 0.0001). Conclusion: The GP4/5 in prostate biopsy specimens is a predictor of BF and DM after RT independent of Gleason score. This parameter should be reported by the pathologist when reviewing prostatic biopsy specimens

  17. A review on the use of bulk specimen X-ray microanalysis in cancer research

    International Nuclear Information System (INIS)

    Zs-Nagy, I.

    1989-01-01

    The freeze-fracture, freeze-drying (FFFD) method of biological bulk specimen preparation combined with quantitative X-ray microanalysis is suitable for the measurement of intracellular concentrations of biologically relevant elements in human biopsy or experimental animal materials. Especially useful information can be obtained regarding the intracellular Na+/K+ ratios being independent of the actual (and unknown) water content of the cytoplasm. The sustained increase of this ratio indicates a sustained depolarization of the cell membrane. These data are of importance from the point of view of the membrane hypothesis of mitogenesis (MHM). It has been revealed that the distribution histograms of the intracellular Na+/K+ ratio display a very significant broadening and an increase of the average values in human urogenital, thyroid and laryngeal tumors, as well as in experimentally induced cell proliferation models. Although MHM has been claimed to be invalid on the basis of some atomic absorption measurements of the intracellular monovalent ion concentrations as well as of some in vitro results obtained with amiloride, this review paper demonstrates that MHM may still be a valid hypothesis for the explanation of mitotic regulation.97 references

  18. Human papillomavirus genotype prevalence in cervical biopsies from women diagnosed with cervical intraepithelial neoplasia or cervical cancer in Fiji.

    Science.gov (United States)

    Tabrizi, Sepehr N; Law, Irwin; Buadromo, Eka; Stevens, Matthew P; Fong, James; Samuela, Josaia; Patel, Mahomed; Mulholland, E Kim; Russell, Fiona M; Garland, Suzanne M

    2011-09-01

    There is currently limited information about human papillomavirus (HPV) genotype distribution in women in the South Pacific region. This study's objective was to determine HPV genotypes present in cervical cancer (CC) and precancers (cervical intraepithelial lesion (CIN) 3) in Fiji. Cross-sectional analysis evaluated archival CC and CIN3 biopsy samples from 296 women of Melanesian Fijian ethnicity (n=182, 61.5%) and Indo-Fijian ethnicity (n=114, 38.5%). HPV genotypes were evaluated using the INNO-LiPA assay in archival samples from CC (n=174) and CIN3 (n=122) among women in Fiji over a 5-year period from 2003 to 2007. Overall, 99% of the specimens tested were HPV DNA-positive for high-risk genotypes, with detection rates of 100%, 97.4% and 100% in CIN3, squamous cell carcinoma (SCC) and adenosquamous carcinoma biopsies, respectively. Genotypes 16 and 18 were the most common (77%), followed by HPV 31 (4.3%). Genotype HPV 16 was the most common identified (59%) in CIN3 specimens, followed by HPV 31 (9%) and HPV 52 (6.6%). Multiple genotypes were detected in 12.5-33.3% of specimens, depending on the pathology. These results indicated that the two most prevalent CC-associated HPV genotypes in Fiji parallel those described in other regions worldwide, with genotype variations thereafter. These data suggest that the currently available bivalent and quadrivalent HPV vaccines could potentially reduce cervical cancers in Fiji by over 80% and reduce precancers by at least 60%.

  19. SHOULD EVERY APPENDECECTOMY SPECIMEN BE SUBJECTED TO HISTOPATHOLOGICAL EXAMINATION? A RETROSPECTIVE STUDY OF HISTOLOGICAL FINDINGS IN APPENDICECTOMY SPECIMENS

    Directory of Open Access Journals (Sweden)

    Shahanuma Shaik

    2017-12-01

    Full Text Available BACKGROUND Appendicitis is one of the commonest surgical emergencies with a lifetime risk of 7-8%. The appendicectomy specimens operated upon clinically-suspected appendicitis often appear normal on gross examination, but histopathological evaluation may reveal a diverse underlying pathology. Therefore, for accurate diagnosis, histopathological examination of all appendicectomy specimens is mandatory. MATERIALS AND METHODS A retrospective study of 175 appendicectomy cases operated over a period of two years. The clinical data and histopathological reports were reviewed and various histopathological findings are categorised. RESULTS Out of the total 175 appendicectomies, 155 emergency appendicectomy cases were included in the study, while 20 cases of incidental appendicectomy were excluded. The peak incidence was found in the 2nd and 3rd decades with male predominance. Among the 155 specimens, 96.8% had histological features of appendicitis and 1.9% were normal appendix. The unusual histopathological findings were Carcinoid tumour and Enterobius vermicularis. CONCLUSION The definitive diagnoses of appendicitis as well as the unusual incidental findings that were missed intraoperatively are established by histopathological examination. The study supports the histological examination of all resected appendicectomy specimens.

  20. Herbarium specimens can reveal impacts of climate change on plant phenology; a review of methods and applications.

    Science.gov (United States)

    Jones, Casey A; Daehler, Curtis C

    2018-01-01

    Studies in plant phenology have provided some of the best evidence for large-scale responses to recent climate change. Over the last decade, more than thirty studies have used herbarium specimens to analyze changes in flowering phenology over time, although studies from tropical environments are thus far generally lacking. In this review, we summarize the approaches and applications used to date. Reproductive plant phenology has primarily been analyzed using two summary statistics, the mean flowering day of year and first-flowering day of year, but mean flowering day has proven to be a more robust statistic. Two types of regression models have been applied to test for associations between flowering, temperature and time: flowering day regressed on year and flowering day regressed on temperature. Most studies analyzed the effect of temperature by averaging temperatures from three months prior to the date of flowering. On average, published studies have used 55 herbarium specimens per species to characterize changes in phenology over time, but in many cases fewer specimens were used. Geospatial grid data are increasingly being used for determining average temperatures at herbarium specimen collection locations, allowing testing for finer scale correspondence between phenology and climate. Multiple studies have shown that inferences from herbarium specimen data are comparable to findings from systematically collected field observations. Understanding phenological responses to climate change is a crucial step towards recognizing implications for higher trophic levels and large-scale ecosystem processes. As herbaria are increasingly being digitized worldwide, more data are becoming available for future studies. As temperatures continue to rise globally, herbarium specimens are expected to become an increasingly important resource for analyzing plant responses to climate change.

  1. Endoscopic biopsy of foramen of Monro and third ventricle lesions guided by frameless neuronavigation: usefulness and limitations.

    Science.gov (United States)

    Prat, Ricardo; Galeano, Inmaculada

    2009-09-01

    To describe our institution experience regarding the usefulness and limitations of frameless neuronavigation in the endoscopic biopsy of foramen of Monro and third ventricle lesions. We report our experience with 22 patients harbouring intraventricular lesions located in the region of the foramen of Monro or the third ventricle who underwent endoscopic biopsy guided by the neuronavigation system. Nine lesions were located on the posterior aspect of the third ventricle or at the pineal region, and thirteen lesions were located at the foramen of Monro or anterior third ventricle region. The endoscopes were introduced via an operating sheath, which had previously been inserted with a trocar under neuronavigational control. After approaching the foramen of Monro from the planned angle, surgery was continued under direct visualisation until the lesion was reached, if it was located on the third ventricle. In cases where the lesion was located at the foramen of Monro, an excellent view of the lesion was obtained and neuronavigation was used to determine the location of critical areas. Histological examination of biopsy specimens obtained endoscopically was diagnostic in all cases. Open surgery following endoscopic biopsy was only needed in 1 patient out of 22. In our experience, image-guided neuroendoscopy can improve the accuracy of the endoscopic approach, minimising brain trauma. It can be particularly helpful when performing a brain biopsy in the absence of clear intraventricular landmarks or in the event of adverse visual conditions such as intraventricular bleeding.

  2. Use of the Prostate Core Mitomic Test in Repeated Biopsy Decision-Making: Real-World Assessment of Clinical Utility in a Multicenter Patient Population.

    Science.gov (United States)

    Legisi, Lorena; DeSa, Elise; Qureshi, M Nasar

    2016-12-01

    Prostate cancer is the most common cancer diagnosed in men in developed countries. Using molecular testing may help to improve outcomes in this clinically challenging group. Since 2011, the Prostate Core Mitomic Test (PCMT), which quantifies a 3.4-kb mitochondrial DNA deletion strongly associated with prostate cancer, has been used by more than 50 urology practices accessing pathology services through our laboratory in New Jersey. However, the use of a molecular test can only be beneficial if it affects patient management and improves outcomes. To determine whether repeated biopsy decision-making was affected in a quantifiable manner through the adjunct use of molecular testing with the PCMT. In this observational study we conducted 2 independent, structured query language database queries of our patient records at our laboratory, QDx Pathology Services, in Cranford, NJ. Query 1 included all men who had a negative prostate biopsy and a negative PCMT between February 1, 2011, and June 30, 2013. Men with a previous diagnosis of cancer were excluded. Query 2 included all men who had a negative prostate biopsy and a repeated biopsy between February 1, 2011, and September 30, 2013. The data exported for each query included the unique specimen number for an index biopsy, the interval between biopsies where present, the unique specimen number for a follow-up biopsy where present, histopathology for all biopsies, the biopsy procedure dates, the patient's date of birth, and the PCMT result when utilized. The patient rebiopsy rates and intervals were compared between the patients who were using PCMT and those who were not to assess whether the adjunct use of the PCMT impacted the rebiopsy decision-making process. Query 1 identified 644 men who had a negative biopsy and a negative PCMT result within the study period. Query 2 identified 823 men with a repeat biopsy after the initial negative index biopsy within the study period. Of these men, 132 had PCMT to inform their care

  3. Combination of prostate imaging reporting and data system (PI-RADS) score and prostate-specific antigen (PSA) density predicts biopsy outcome in prostate biopsy naïve patients.

    Science.gov (United States)

    Washino, Satoshi; Okochi, Tomohisa; Saito, Kimitoshi; Konishi, Tsuzumi; Hirai, Masaru; Kobayashi, Yutaka; Miyagawa, Tomoaki

    2017-02-01

    To assess the value of the Prostate Imaging Reporting and Data System (PI-RADS) scoring system, for prostate multi-parametric magnetic resonance imaging (mpMRI) to detect prostate cancer, and classical parameters, such as prostate-specific antigen (PSA) level, prostate volume and PSA density, for predicting biopsy outcome in biopsy naïve patients who have suspected prostate cancer. Patients who underwent mpMRI at our hospital, and who had their first prostate biopsy between July 2010 and April 2014, were analysed retrospectively. The prostate biopsies were taken transperineally under transrectal ultrasonography guidance. In all, 14 cores were biopsied as a systematic biopsy in all patients. Two cognitive fusion-targeted biopsy cores were added for each lesion in patients who had suspicious or equivocal lesions on mpMRI. The PI-RADS scoring system version 2.0 (PI-RADS v2) was used to describe the MRI findings. Univariate and multivariate analyses were performed to determine significant predictors of prostate cancer and clinically significant prostate cancer. In all, 288 patients were analysed. The median patient age, PSA level, prostate volume and PSA density were 69 years, 7.5 ng/mL, 28.7 mL, and 0.26 ng/mL/mL, respectively. The biopsy results were benign, clinically insignificant, and clinically significant prostate cancer in 129 (45%), 18 (6%) and 141 (49%) patients, respectively. The multivariate analysis revealed that PI-RADS v2 score and PSA density were independent predictors for prostate cancer and clinically significant prostate cancer. When PI-RADS v2 score and PSA density were combined, a PI-RADS v2 score of ≥4 and PSA density ≥0.15 ng/mL/mL, or PI-RADS v2 score of 3 and PSA density of ≥0.30 ng/mL/mL, was associated with the highest clinically significant prostate cancer detection rates (76-97%) on the first biopsy. Of the patients in this group with negative biopsy results, 22% were subsequently diagnosed as prostate cancer. In contrast, a PI

  4. Liver biopsy under hypnosis.

    Science.gov (United States)

    Adams, P C; Stenn, P G

    1992-09-01

    Two patients underwent outpatient percutaneous liver biopsy under hypnosis without complications. One patient had severe anxiety about the procedure because of a previous adverse experience with liver biopsy and the other had a history of severe allergy to local anesthesia. Both patients had undergone a session of hypnosis at least once prior to the biopsy. One received no local anesthetic and the other received 1% lidocaine as a local anesthetic. Both patients were completely cooperative during the procedure with the required respiratory maneuvers. Both patients stated that they were aware of the procedure under hypnosis but described no pain and would be most willing to have the procedure done under hypnosis in the future. Hypnosis can be a useful method of preparing carefully selected patients for percutaneous liver biopsy.

  5. DNA analysis of herbarium Specimens of the grass weed Alopecurus myosuroides reveals herbicide resistance pre-dated herbicides.

    Science.gov (United States)

    Délye, Christophe; Deulvot, Chrystel; Chauvel, Bruno

    2013-01-01

    Acetyl-CoA carboxylase (ACCase) alleles carrying one point mutation that confers resistance to herbicides have been identified in arable grass weed populations where resistance has evolved under the selective pressure of herbicides. In an effort to determine whether herbicide resistance evolves from newly arisen mutations or from standing genetic variation in weed populations, we used herbarium specimens of the grass weed Alopecurus myosuroides to seek mutant ACCase alleles carrying an isoleucine-to-leucine substitution at codon 1781 that endows herbicide resistance. These specimens had been collected between 1788 and 1975, i.e., prior to the commercial release of herbicides inhibiting ACCase. Among the 734 specimens investigated, 685 yielded DNA suitable for PCR. Genotyping the ACCase locus using the derived Cleaved Amplified Polymorphic Sequence (dCAPS) technique identified one heterozygous mutant specimen that had been collected in 1888. Occurrence of a mutant codon encoding a leucine residue at codon 1781 at the heterozygous state was confirmed in this specimen by sequencing, clearly demonstrating that resistance to herbicides can pre-date herbicides in weeds. We conclude that point mutations endowing resistance to herbicides without having associated deleterious pleiotropic effects can be present in weed populations as part of their standing genetic variation, in frequencies higher than the mutation frequency, thereby facilitating their subsequent selection by herbicide applications.

  6. Biopsy-proven childhood glomerulonephritis in Johor.

    Science.gov (United States)

    Khoo, J J; Pee, S; Thevarajah, B; Yap, Y C; Chin, C K

    2004-06-01

    There has been no published study of biopsy-proven childhood glomerulonephritis in Malaysia. To determine the pattern of childhood glomerulonephritis in Johor, Malaysia from a histopathological perspective and the various indications used for renal biopsy in children. Retrospective study was done of all renal biopsies from children under 16 years of age, received in Sultanah Aminah Hospital, Johor between 1994 and 2001. The histopathological findings were reviewed to determine the pattern of biopsy-proven glomerulonephritis. The indications for biopsy, mode of therapy given after biopsy and the clinical outcome were studied. 122 adequate biopsies were received, 9 children had repeat biopsies. Of the 113 biopsies, minimal change disease formed the most common histopathological diagnosis (40.7%) while lupus nephritis formed the most common secondary glomerulonephritis (23.0%). The main indications for biopsy were nephrotic syndrome (50.8%), lupus nephritis (25.4%) and renal impairment (13.1%). The mode of therapy was changed in 59.8% of the children. Of 106 patients followed-up, 84 children were found to have normal renal function in remission or on treatment. 4 patients developed chronic renal impairment and 16 reached end stage renal disease. Five of the 16 children with end stage disease had since died while 11 were on renal replacement therapy. Another 2 patients died of other complications. The pattern of childhood GN in our study tended to reflect the more severe renal parenchymal diseases in children and those requiring more aggressive treatment. This was because of our criteria of selection (indication) for renal biopsy. Renal biopsy where performed appropriately in selected children may not only be a useful investigative tool for histological diagnosis and prognosis but may help clinicians plan the optimal therapy for these children.

  7. The Role of Biopsy in Pediatric Dermatopathology

    Directory of Open Access Journals (Sweden)

    Fatma Şule Afşa

    2011-09-01

    Full Text Available Background and Design: Pediatric dermatology is characterized by skin disorders which have frequencies different from those in adults. Skin biopsies are necessary for differential diagnosis and clinicopathologic correlation is very important. The aim of this study was to evaluate retrospectively the pediatric dermatology cases in whom biopsy was performed for differential diagnosis and to investigate the contribution of biopsy to diagnosis of skin disorders. Material and Methods: The cases from whom biopsy was taken in the pediatric dermatology clinic during a three-year period were evaluated retrospectively for pre-diagnoses, biopsy diagnoses, and success of biopsies.Results: Two hundred thirteen (1.7% skin biopsies had been taken from a total of 12420 patients. Henoch-Schönlein purpura, psoriasis, pityriasis lichenoides, pityriasis rosea, lichen planus, pityriasis rubra pilaris, erythema multiforme, atopic dermatitis, granuloma annulare, and pigmented purpuric dermatosis were the most frequent skin disorders diagnosed dermatopathologically. In a total of 120 (56.3% cases, the biopsy diagnosis was within the pre-diagnosis and a biopsy consistency was present. In 25 (11.7% cases, biopsy had no contribution to the differential diagnosis. An absolutely different diagnosis which was incompatible with the pre-diagnosis had been reported in 10 (4.6% cases. Conclusion: In pediatric dermatology, skin biopsy is very helpful for the differential diagnosis. An easy biopsy procedure for the patient, an effective designation of biopsy indication, a good dermatopathologic correlation and an experienced team of pediatric dermatopathology increase the success of skin biopsies.

  8. Blood specimen labelling errors: Implications for nephrology nursing practice.

    Science.gov (United States)

    Duteau, Jennifer

    2014-01-01

    Patient safety is the foundation of high-quality health care, as recognized both nationally and worldwide. Patient blood specimen identification is critical in ensuring the delivery of safe and appropriate care. The practice of nephrology nursing involves frequent patient blood specimen withdrawals to treat and monitor kidney disease. A critical review of the literature reveals that incorrect patient identification is one of the major causes of blood specimen labelling errors. Misidentified samples create a serious risk to patient safety leading to multiple specimen withdrawals, delay in diagnosis, misdiagnosis, incorrect treatment, transfusion reactions, increased length of stay and other negative patient outcomes. Barcode technology has been identified as a preferred method for positive patient identification leading to a definitive decrease in blood specimen labelling errors by as much as 83% (Askeland, et al., 2008). The use of a root cause analysis followed by an action plan is one approach to decreasing the occurrence of blood specimen labelling errors. This article will present a review of the evidence-based literature surrounding blood specimen labelling errors, followed by author recommendations for completing a root cause analysis and action plan. A failure modes and effects analysis (FMEA) will be presented as one method to determine root cause, followed by the Ottawa Model of Research Use (OMRU) as a framework for implementation of strategies to reduce blood specimen labelling errors.

  9. Preliminary investigation of candidate specimens for the Egyptian environmental specimen bank

    International Nuclear Information System (INIS)

    Shawky, S.; Amer, H.; Schladot, J.D.; Ostapczuk, P.; Emons, H.; Abou El-Nour, F.

    2000-01-01

    In the frame of establishing an environmental monitoring program related to environmental specimen banking in egypt, some candidate specimens from the aquatic environment (Fish muscle, fish liver; mussels) were investigated. The selection of specimens and sampling sites is described. Specimens are chemically characterised with respect to some major and trace elements and the results are compared with data obtained from comparable specimens collected in aquatic ecosystems of germany

  10. Adaptation of a 3D prostate cancer atlas for transrectal ultrasound guided target-specific biopsy

    International Nuclear Information System (INIS)

    Narayanan, R; Suri, J S; Werahera, P N; Barqawi, A; Crawford, E D; Shinohara, K; Simoneau, A R

    2008-01-01

    Due to lack of imaging modalities to identify prostate cancer in vivo, current TRUS guided prostate biopsies are taken randomly. Consequently, many important cancers are missed during initial biopsies. The purpose of this study was to determine the potential clinical utility of a high-speed registration algorithm for a 3D prostate cancer atlas. This 3D prostate cancer atlas provides voxel-level likelihood of cancer and optimized biopsy locations on a template space (Zhan et al 2007). The atlas was constructed from 158 expert annotated, 3D reconstructed radical prostatectomy specimens outlined for cancers (Shen et al 2004). For successful clinical implementation, the prostate atlas needs to be registered to each patient's TRUS image with high registration accuracy in a time-efficient manner. This is implemented in a two-step procedure, the segmentation of the prostate gland from a patient's TRUS image followed by the registration of the prostate atlas. We have developed a fast registration algorithm suitable for clinical applications of this prostate cancer atlas. The registration algorithm was implemented on a graphical processing unit (GPU) to meet the critical processing speed requirements for atlas guided biopsy. A color overlay of the atlas superposed on the TRUS image was presented to help pick statistically likely regions known to harbor cancer. We validated our fast registration algorithm using computer simulations of two optimized 7- and 12-core biopsy protocols to maximize the overall detection rate. Using a GPU, patient's TRUS image segmentation and atlas registration took less than 12 s. The prostate cancer atlas guided 7- and 12-core biopsy protocols had cancer detection rates of 84.81% and 89.87% respectively when validated on the same set of data. Whereas the sextant biopsy approach without the utility of 3D cancer atlas detected only 70.5% of the cancers using the same histology data. We estimate 10-20% increase in prostate cancer detection rates

  11. Prostate cancer-associated gene expression alterations determined from needle biopsies.

    Science.gov (United States)

    Qian, David Z; Huang, Chung-Ying; O'Brien, Catherine A; Coleman, Ilsa M; Garzotto, Mark; True, Lawrence D; Higano, Celestia S; Vessella, Robert; Lange, Paul H; Nelson, Peter S; Beer, Tomasz M

    2009-05-01

    To accurately identify gene expression alterations that differentiate neoplastic from normal prostate epithelium using an approach that avoids contamination by unwanted cellular components and is not compromised by acute gene expression changes associated with tumor devascularization and resulting ischemia. Approximately 3,000 neoplastic and benign prostate epithelial cells were isolated using laser capture microdissection from snap-frozen prostate biopsy specimens provided by 31 patients who subsequently participated in a clinical trial of preoperative chemotherapy. cDNA synthesized from amplified total RNA was hybridized to custom-made microarrays composed of 6,200 clones derived from the Prostate Expression Database. Expression differences for selected genes were verified using quantitative reverse transcription-PCR. Comparative analyses identified 954 transcript alterations associated with cancer (q transport. Genes down-regulated in prostate cancers were enriched in categories related to immune response, cellular responses to pathogens, and apoptosis. A heterogeneous pattern of androgen receptor expression changes was noted. In exploratory analyses, androgen receptor down-regulation was associated with a lower probability of cancer relapse after neoadjuvant chemotherapy followed by radical prostatectomy. Assessments of tumor phenotypes based on gene expression for treatment stratification and drug targeting of oncogenic alterations may best be ascertained using biopsy-based analyses where the effects of ischemia do not complicate interpretation.

  12. Mistaken identity: Legionella micdadei appearing as acid-fast bacilli on lung biopsy of a hematopoietic stem cell transplant patient.

    Science.gov (United States)

    Waldron, P R; Martin, B A; Ho, D Y

    2015-02-01

    Legionella micdadei is a potential cause of invasive lung infections in immunocompromised hosts. On biopsy specimens, it can appear as an acid-fast bacillus (AFB) and can be mistaken for a member of genus Mycobacterium. As Legionella requires selective media to grow in culture, and the commonly used, commercially available urine antigen test for Legionella only detects Legionella pneumophila serogroup-1, but not L. micdadei, it is important to consider this organism in the differential diagnosis for AFB in immunocompromised hosts. We report a case of L. micdadei infection, which was initially treated empirically for non-tuberculous mycobacteria based on AFB staining of biopsy tissue before the final diagnosis was made. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  13. CT-guided biopsy with cutting-edge needle for the diagnosis of malignant lymphoma: Experience of 267 biopsies

    International Nuclear Information System (INIS)

    Agid, R.; Sklair-Levy, M.; Bloom, A.I.; Lieberman, S.; Polliack, A.; Ben-Yehuda, D.; Sherman, Y.; Libson, E.

    2003-01-01

    AIM: We performed a retrospective study of 267 core needle aspiration biopsies in order to estimate the accuracy of CT-guided aspiration core needle biopsies for the diagnosis and subsequent treatment of malignant lymphoma. MATERIALS AND METHODS: Between 1989 and 1999, 267 CT-guided core needle biopsies were performed in 241 patients with either primary or recurrent malignant lymphoma. Patients age ranged from 4--88 years. One hundred and sixty-six (62.2%) nodal and 101 (37.8%) extranodal aspiration biopsies were performed using either 18 G or 20 G Turner needles. Statistical method used was Chi-square analysis. RESULTS: An accurate histological diagnosis was made in 199 (82.5%) patients, the remaining 42 (17.4%) patients had non-diagnostic CT biopsies. Thirty-seven of them were diagnosed by a surgical biopsy, four by bone marrow biopsy and in one patient by paracentesis. One hundred and seventy-nine patients had non-Hodgkin's lymphoma (NHL) and 62 had Hodgkin's disease (HD); 23 (9.54%) patients underwent repeated CT biopsy which was diagnostic in 17 (73.9%) and non-diagnostic in six (26%). CONCLUSION: CT-guided aspiration core biopsies were sufficient to establish a diagnosis in lymphoproliferative disorders in 82.5% of cases. In the light of this experience we suggest that imaging-guided core needle biopsy be used as the first step in the work up of many patients with lymphoma Agid,R. et al. (2003). Clinical Radiology58, 143-147

  14. Liquid biopsy for brain tumors

    Science.gov (United States)

    Shankar, Ganesh M.; Balaj, Leonora; Stott, Shannon L.; Nahed, Brian; Carter, Bob S.

    2018-01-01

    Introduction Minimally invasive methods will augment the clinical approach for establishing the diagnosis or monitoring treatment response of central nervous system tumors. Liquid biopsy by blood or cerebrospinal fluid sampling holds promise in this regard. Areas covered In this literature review, the authors highlight recent studies describing the analysis of circulating tumor cells, cell free nucleic acids, and extracellular vesicles as strategies to accomplish liquid biopsy in glioblastoma and metastatic tumors. The authors then discuss the continued efforts to improve signal detection, standardize the liquid biopsy handling and preparation, develop platforms for clinical application, and establish a role for liquid biopsies in personalized medicine. Expert commentary As the technologies used to analyze these biomarkers continue to evolve, we propose that there is a future potential to precisely diagnose and monitor treatment response with liquid biopsies. PMID:28875730

  15. Intraductal Carcinoma of the Prostate on Diagnostic Needle Biopsy Predicts Prostate Cancer Mortality: A Population-Based Study.

    Science.gov (United States)

    Saeter, Thorstein; Vlatkovic, Ljiljana; Waaler, Gudmund; Servoll, Einar; Nesland, Jahn M; Axcrona, Karol; Axcrona, Ulrika

    2017-06-01

    Intraductal carcinoma of the prostate (IDC-P) is a distinct histopathologic feature associated with high-grade, advanced prostate cancer. Although studies have shown that IDC-P is a predictor of progression following surgical or radiation treatment for prostate cancer, there are sparse data regarding IDC-P on diagnostic needle biopsy as a prognosticator of prostate cancer mortality. This was a population-based study of all prostate cancer patients diagnosed using needle biopsy and without evidence of systemic disease between 1991 and 1999 within a defined geographic region of Norway. Patients were identified by cross-referencing the Norwegian Cancer Registry. Of 318 eligible patients, 283 had biopsy specimens available for central pathology review. Clinical data were obtained from medical charts. We examined whether IDC-P on diagnostic needle biopsy was associated with adverse clinicopathological features and prostate cancer mortality. Patients with IDC-P on diagnostic needle biopsy had a more advanced stage and a higher Gleason score compared to patients without IDC-P. IDC-P was also associated with an intensively reactive stroma. The 10-year prostate cancer-specific survival was 69% for patients with IDC-P on diagnostic needle biopsy and 89% for patients without IDC-P (Log rank P-value prostate cancer mortality after adjustments for clinical prognostic factors and treatment. After adjustment for the newly implemented Grade Group system of prostate cancer, IDC-P showed a strong tendency toward statistical significance. However, IDC-P did not remain a statistically significant predictor in the multivariable analysis. IDC-P on diagnostic needle biopsy is an indicator of prostate cancer with a high risk of mortality. Accordingly, a diagnosis of IDC-P on needle biopsy should be reported and considered a feature of high-risk prostate cancer. Moreover, the association between IDC-P and reactive stroma provides evidence in support of the idea that stromal factors

  16. Magnetic resonance imaging-guided biopsies may improve diagnosis in biopsy-naive men with suspicion of prostate cancer

    DEFF Research Database (Denmark)

    Winther, Mads Dochedahl; Balslev, Ingegerd; Boesen, Lars

    2017-01-01

    INTRODUCTION: The purpose of this pilot study was to investigate whether a short prostate biparametric magnetic resonance imaging (bp-MRI) protocol provides a valuable diagnostic addition for biopsy guidance in biopsy-naive men with a suspicion of prostate cancer (PCa). METHODS: A total of 62...... biopsy-naive patients referred to a systematic transrectal ultrasound biopsy (TRUS-bx) due to suspicion of PCa were prospectively enrolled. Bp-MRI was performed before biopsy. All lesions were scored according to the modified Prostate Imaging Reporting and Data System (PI-RADS) version 2. All patients...

  17. Recurrent nodule on the nasal columella: a good reason to re-biopsy.

    Science.gov (United States)

    Vujevich, Justin J; Goldberg, Leonard H; Kimyai-Asadi, Arash; Law, Robert

    2008-07-01

    A 15-year-old Caucasian male presented with 9-month history of a recurrent nodule on the nasal columella. The previous biopsy was reported as a neurofibroma. Frozen sections revealed a spindle cell neoplasm. Permanent section immunohistochemistry sections stained positive for vimentin and smooth muscle actin and negative for S100 and CD34, confirming the diagnosis of leiomyosarcoma. The tumor was removed using Mohs micrographic surgery. Radiological work-up revealed no distant metastasis. There has been no local recurrence to date. Leiomyosarcoma is a difficult diagnosis to make clinically and requires histological confirmation. Re-biopsy of a "benign" growth may be necessary if clinicopathological correlation does not match with the clinical behavior of the tumor in question. Finally, Mohs micrographic surgery is a useful treatment modality for leiomyosarcomas, particularly those located in cosmetically-sensitive regions of the body such as the nose.

  18. A tissue biopsy-based epigenetic multiplex PCR assay for prostate cancer detection

    Directory of Open Access Journals (Sweden)

    Van Neste Leander

    2012-06-01

    Full Text Available Abstract Background PSA-directed prostate cancer screening leads to a high rate of false positive identifications and an unnecessary biopsy burden. Epigenetic biomarkers have proven useful, exhibiting frequent and abundant inactivation of tumor suppressor genes through such mechanisms. An epigenetic, multiplex PCR test for prostate cancer diagnosis could provide physicians with better tools to help their patients. Biomarkers like GSTP1, APC and RASSF1 have demonstrated involvement with prostate cancer, with the latter two genes playing prominent roles in the field effect. The epigenetic states of these genes can be used to assess the likelihood of cancer presence or absence. Results An initial test cohort of 30 prostate cancer-positive samples and 12 cancer-negative samples was used as basis for the development and optimization of an epigenetic multiplex assay based on the GSTP1, APC and RASSF1 genes, using methylation specific PCR (MSP. The effect of prostate needle core biopsy sample volume and age of formalin-fixed paraffin-embedded (FFPE samples was evaluated on an independent follow-up cohort of 51 cancer-positive patients. Multiplexing affects copy number calculations in a consistent way per assay. Methylation ratios are therefore altered compared to the respective singleplex assays, but the correlation with patient outcome remains equivalent. In addition, tissue-biopsy samples as small as 20 μm can be used to detect methylation in a reliable manner. The age of FFPE-samples does have a negative impact on DNA quality and quantity. Conclusions The developed multiplex assay appears functionally similar to individual singleplex assays, with the benefit of lower tissue requirements, lower cost and decreased signal variation. This assay can be applied to small biopsy specimens, down to 20 microns, widening clinical applicability. Increasing the sample volume can compensate the loss of DNA quality and quantity in older samples.

  19. Magnetic Resonance Imaging-Guided Osseous Biopsy in Children With Chronic Recurrent Multifocal Osteomyelitis

    International Nuclear Information System (INIS)

    Fritz, Jan; Tzaribachev, Nikolay; Thomas, Christoph; Wehrmann, Manfred; Horger, Marius S.; Carrino, John A.; König, Claudius W.; Pereira, Philippe L.

    2012-01-01

    Purpose: To report the safety and diagnostic performance of magnetic resonance (MRI)—guided core biopsy of osseous lesions in children with chronic recurrent multifocal osteomyelitis (CRMO) that were visible on MRI but were occult on radiography and computed tomography (CT). Materials and Methods: A retrospective analysis of MRI-guided osseous biopsy performed in seven children (four girls and three boys; mean age 13 years (range 11 to 14) with CRMO was performed. Indication for using MRI guidance was visibility of lesions by MRI only. MRI-guided procedures were performed with 0.2-Tesla (Magnetom Concerto; Siemens, Erlangen, Germany; n = 5) or 1.5-T (Magnetom Espree; Siemens; n = 2) open MRI systems. Core needle biopsy was obtained using an MRI-compatible 4-mm drill system. Conscious sedation or general anesthesia was used. Parameters evaluated were lesion visibility, technical success, procedure time, complications and microbiology, cytology, and histopathology findings. Results: Seven of seven (100%) targeted lesions were successfully visualized and sampled. All obtained specimens were sufficient for histopathological analysis. Length of time of the procedures was 77 min (range 64 to 107). No complications occurred. Histopathology showed no evidence of malignancy, which was confirmed at mean follow-up of 50 months (range 28 to 78). Chronic nonspecific inflammation characteristic for CRMO was present in four of seven (58%) patients, and edema with no inflammatory cells was found in three of seven (42%) patients. There was no evidence of infection in any patient. Conclusion: MRI-guided osseous biopsy is a safe and accurate technique for the diagnosis of pediatric CRMO lesions that are visible on MRI only.

  20. Stereotactic large-core needle breast biopsy: analysis of pain and discomfort related to the biopsy procedure

    International Nuclear Information System (INIS)

    Hemmer, Judith M.; Heesewijk, Hans P.M. van; Kelder, Johannes C.

    2008-01-01

    The purpose of this study was to determine the significance of variables such as duration of the procedure, type of breast tissue, number of passes, depth of the biopsies, underlying pathology, the operator performing the procedure, and their effect on women's perception of pain and discomfort during stereotactic large-core needle breast biopsy. One hundred and fifty consecutive patients with a non-palpable suspicious mammographic lesions were included. Between three and nine 14-gauge breast passes were taken using a prone stereotactic table. Following the biopsy procedure, patients were asked to complete a questionnaire. There was no discomfort in lying on the prone table. There is no relation between type of breast lesion and pain, underlying pathology and pain and performing operator and pain. The type of breast tissue is correlated with pain experienced from biopsy (P = 0.0001). We found out that patients with dense breast tissue complain of more pain from biopsy than patients with more involution of breast tissue. The depth of the biopsy correlates with pain from biopsy (P = 0.0028). Deep lesions are more painful than superficial ones. There is a correlation between the number of passes and pain in the neck (P = 0.0188) and shoulder (P = 0.0366). The duration of the procedure is correlated with pain experienced in the neck (P = 0.0116) but not with pain experienced from biopsy. (orig.)

  1. Freehand biopsy guided by electromagnetic needle tracking

    DEFF Research Database (Denmark)

    Ewertsen, C; Nielsen, Marie Kristina Rue; Nielsen, M Bachmann

    2011-01-01

    To evaluate the overall accuracy and time spent on biopsy guided by electromagnetic needle tracking in a phantom compared with the standard technique of US-guided biopsy with an attached steering device. Furthermore, to evaluate off-plane biopsy guided by needle tracking.......To evaluate the overall accuracy and time spent on biopsy guided by electromagnetic needle tracking in a phantom compared with the standard technique of US-guided biopsy with an attached steering device. Furthermore, to evaluate off-plane biopsy guided by needle tracking....

  2. Tensile and Creep Testing of Sanicro 25 Using Miniature Specimens

    Science.gov (United States)

    Dymáček, Petr; Jarý, Milan; Dobeš, Ferdinand; Kloc, Luboš

    2018-01-01

    Tensile and creep properties of new austenitic steel Sanicro 25 at room temperature and operating temperature 700 °C were investigated by testing on miniature specimens. The results were correlated with testing on conventional specimens. Very good agreement of results was obtained, namely in yield and ultimate strength, as well as short-term creep properties. Although the creep rupture time was found to be systematically shorter and creep ductility lower in the miniature test, the minimum creep rates were comparable. The analysis of the fracture surfaces revealed similar ductile fracture morphology for both specimen geometries. One exception was found in a small area near the miniature specimen edge that was cut by electro discharge machining, where an influence of the steel fracture behavior at elevated temperature was identified. PMID:29337867

  3. Tensile and Creep Testing of Sanicro 25 Using Miniature Specimens.

    Science.gov (United States)

    Dymáček, Petr; Jarý, Milan; Dobeš, Ferdinand; Kloc, Luboš

    2018-01-16

    Tensile and creep properties of new austenitic steel Sanicro 25 at room temperature and operating temperature 700 °C were investigated by testing on miniature specimens. The results were correlated with testing on conventional specimens. Very good agreement of results was obtained, namely in yield and ultimate strength, as well as short-term creep properties. Although the creep rupture time was found to be systematically shorter and creep ductility lower in the miniature test, the minimum creep rates were comparable. The analysis of the fracture surfaces revealed similar ductile fracture morphology for both specimen geometries. One exception was found in a small area near the miniature specimen edge that was cut by electro discharge machining, where an influence of the steel fracture behavior at elevated temperature was identified.

  4. Comparison between hemosiderin and Technetium-99 in sentinel lymph node biopsy in human breast cancer

    International Nuclear Information System (INIS)

    Vasques, Paulo Henrique Diogenes; Aquino, Ranniere Gurgel Furtado de; Pinheiro, Luiz Gonzaga Porto; Torres, Roberto Vitor Almeida; Bezerra, Jose Lucas Martins; Brasileiro, Luis Porto

    2015-01-01

    Purpose: To assess the safety and potential equivalence of the use of hemosiderin compared to the Technetium-99 in sentinel lymph node biopsy in human breast cancer. Methods: Non-random sample of 14 volunteer women diagnosed with breast cancer with primary tumors (T1/T2) and clinically tumor-free axilla were submitted to the identification of sentinel lymph node using hemosiderin obtained from autologous blood injected in the periareolar region 24h before surgery on an outpatient basis. Patients received preoperative subareolar intradermal injection of Technetium-99 in the immediate preoperative period. Patients were submitted to sentinel lymph node biopsy, with incision in the axillary fold guided by Gamma-Probe, dissection by planes until the identification of the point of maximum uptake of Technetium-99, identifying the marked nodes and their colors. All surgical specimens were sent for pathological and immunohistochemical study. Results: The results showed no evidence of side effects and/or allergic and non-allergic reactions in patients submitted to SLNB with hemosiderin. The SLN identification rate per patient was 100%. SLNB identification rate per patient with hemosiderin was the same as that of Technetium, with a concordance rate of 100% between the methods. Conclusion: Hemosiderin is a safe dye that is equivalent to Technetium in breast sentinel lymph node biopsy. (author)

  5. Comparison between hemosiderin and Technetium-99 in sentinel lymph node biopsy in human breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Vasques, Paulo Henrique Diogenes; Aquino, Ranniere Gurgel Furtado de; Pinheiro, Luiz Gonzaga Porto, E-mail: luizgporto@uol.com.br [Universidade Federal do Ceara (UFC), Fortaleza, CE (Brazil). Departamento de Cirurgia; Alves, Mayara Maia [Rede Nordeste de Biotecnologia (RENORBIO/UFC), Fortaleza, CE (Brazil); Torres, Roberto Vitor Almeida; Bezerra, Jose Lucas Martins [Universidade Federal do Ceara (UFC), Fortaleza, CE (Brazil). Faculdade de Medicina; Brasileiro, Luis Porto [Faculdades INTA, Sobral, CE (Brazil). Faculdade de Medicina

    2015-11-15

    Purpose: To assess the safety and potential equivalence of the use of hemosiderin compared to the Technetium-99 in sentinel lymph node biopsy in human breast cancer. Methods: Non-random sample of 14 volunteer women diagnosed with breast cancer with primary tumors (T1/T2) and clinically tumor-free axilla were submitted to the identification of sentinel lymph node using hemosiderin obtained from autologous blood injected in the periareolar region 24h before surgery on an outpatient basis. Patients received preoperative subareolar intradermal injection of Technetium-99 in the immediate preoperative period. Patients were submitted to sentinel lymph node biopsy, with incision in the axillary fold guided by Gamma-Probe, dissection by planes until the identification of the point of maximum uptake of Technetium-99, identifying the marked nodes and their colors. All surgical specimens were sent for pathological and immunohistochemical study. Results: The results showed no evidence of side effects and/or allergic and non-allergic reactions in patients submitted to SLNB with hemosiderin. The SLN identification rate per patient was 100%. SLNB identification rate per patient with hemosiderin was the same as that of Technetium, with a concordance rate of 100% between the methods. Conclusion: Hemosiderin is a safe dye that is equivalent to Technetium in breast sentinel lymph node biopsy. (author)

  6. Comparison of plain potassium hydroxide mounts, fungal cultures and nail plate biopsies in the diagnosis of onychomycosis

    International Nuclear Information System (INIS)

    Malik, N.A.; Nasiruddin, A.

    2006-01-01

    To compare the relative sensitivity of direct microscopy, fungal culture and nail plate biopsy in the diagnosis of onychomycosis. A total of 50 patients who were suffering from different clinical variants of onychomycosis, irrespective of their age, gender, with or without simultaneous presence of systemic diseases, were subjected to laboratory investigations including direct microscopy with 20% potassium hydroxide (KOH) for fungal hyphae, fungal cultures and nail plate biopsies. These patients were later categorized into two groups based upon the results of nail plate biopsies. Of 50 patients, 15 (30%) were positive for fungal elements in direct microscopy, 8 (16%) were positive for fungal culture and 16 (32%) revealed positive results in nail plate biopsies. Amongst nail plate biopsy positive cases, 10 (63%) were positive for direct microscopy and 6 (37.5%) were positive for fungal cultures. In biopsy negative cases, positive results for direct microscopy were seen in 5 (14.7%) patients and positive fungal culture was found in 2 (5.88%) patients. (author)

  7. C-arm cone-beam CT combined with a new electromagnetic navigation system for guidance of percutaneous needle biopsies. Initial clinical experience

    Energy Technology Data Exchange (ETDEWEB)

    Kickuth, R.; Reichling, C.; Bley, T.; Hahn, D.; Ritter, C. [University Hospital of Wuerzburg (Germany). Inst. of Diagnostic and Interventional Radiology

    2015-07-15

    To evaluate the feasibility and efficacy of C-arm fluoroscopic cone-beam computed tomography (CACT) in combination with a new electromagnetic tracking (EMT) system for needle guidance during percutaneous biopsies. 53 patients were referred for biopsy of thoracic (n = 19) and abdominal (n = 34) lesions. CT-like images of the anatomical region of interest (ROI) were generated using a flat panel-based angiographic system. These images were transmitted to an EMT system. A coaxial puncture needle with a sensor in its tip was connected with the navigation system and tracked into an electromagnetic field created via a field generator. Data generated within this field were merged with the CACT images. On a monitor both the anatomical ROI and needle tip position were displayed to enable precise needle insertion into the target. Through the coaxial needle, biopsy specimens for the histologic evaluation were extracted. Number of representative biopsy samples, number of core biopsies/patient, total procedure time, dose-area product, fluoroscopic time, and complications were recorded. 53 CACT/EMT-guided biopsy procedures were performed, 48 of which (91 %) yielded representative tissue samples. Four core biopsies were obtained from each patient. 40 (75 %) lesions were malignant and 13 (25 %) lesions were benign. The total procedure time was 9 ± 5 min (range, 3 - 23 min), fluoroscopic time was 0.8 ± 0.4 min (range, 0.4 - 2 min). The mean dose-area product (cGy cm{sup 2}) was 7373 (range, 895 - 26 904). The rate of complications (1 pneumothorax, 2 hemoptyses) was 6 %. CACT combined with EMT appears to be a feasible and effective technique for the guidance of percutaneous biopsies with a low rate of therapeutically relevant complications.

  8. C-arm cone-beam CT combined with a new electromagnetic navigation system for guidance of percutaneous needle biopsies. Initial clinical experience

    International Nuclear Information System (INIS)

    Kickuth, R.; Reichling, C.; Bley, T.; Hahn, D.; Ritter, C.

    2015-01-01

    To evaluate the feasibility and efficacy of C-arm fluoroscopic cone-beam computed tomography (CACT) in combination with a new electromagnetic tracking (EMT) system for needle guidance during percutaneous biopsies. 53 patients were referred for biopsy of thoracic (n = 19) and abdominal (n = 34) lesions. CT-like images of the anatomical region of interest (ROI) were generated using a flat panel-based angiographic system. These images were transmitted to an EMT system. A coaxial puncture needle with a sensor in its tip was connected with the navigation system and tracked into an electromagnetic field created via a field generator. Data generated within this field were merged with the CACT images. On a monitor both the anatomical ROI and needle tip position were displayed to enable precise needle insertion into the target. Through the coaxial needle, biopsy specimens for the histologic evaluation were extracted. Number of representative biopsy samples, number of core biopsies/patient, total procedure time, dose-area product, fluoroscopic time, and complications were recorded. 53 CACT/EMT-guided biopsy procedures were performed, 48 of which (91 %) yielded representative tissue samples. Four core biopsies were obtained from each patient. 40 (75 %) lesions were malignant and 13 (25 %) lesions were benign. The total procedure time was 9 ± 5 min (range, 3 - 23 min), fluoroscopic time was 0.8 ± 0.4 min (range, 0.4 - 2 min). The mean dose-area product (cGy cm 2 ) was 7373 (range, 895 - 26 904). The rate of complications (1 pneumothorax, 2 hemoptyses) was 6 %. CACT combined with EMT appears to be a feasible and effective technique for the guidance of percutaneous biopsies with a low rate of therapeutically relevant complications.

  9. Cutting needle biopsy combined with immunohistochemical study of myeloperoxidase for the diagnosis of histiocytic necrotizing lymphadenitis.

    Science.gov (United States)

    Hanakawa, Hiroyuki; Orita, Yorihisa; Sato, Yasuharu; Takeuchi, Mai; Ohno, Kyotaro; Iwaki, Noriko; Ito, Toshihiro; Nishizaki, Kazunori; Yoshino, Tadashi

    2013-12-01

    Cutting needle biopsy (CNB) combined with immunohistochemical study of myeloperoxidase (MPO) is a useful minimally invasive diagnostic procedure for histiocytic necrotizing lymphadenitis (HNL). HNL is mainly diagnosed by pathological findings of open surgical biopsy (OSB) specimens. Recently the appearance of anti-MPO positive histiocytes has been reported as a highly specific pathological diagnosis for HNL. Considering the cosmetic impact and burden on the patients, we performed CNB combined with immunohistochemical study of MPO for the diagnosis of HNL. Few studies have reported the utility of this method in the diagnosis of HNL. A retrospective study was conducted using clinical data from 20 HNL patients. CNB was performed in 8 patients and OSB in 13 (OSB after CNB in 1). MPO-positive histiocytes were observed in all of the 20 cases. The accuracy of the diagnoses was finally confirmed by the clinical courses in all cases.

  10. Keratosis reduces sensitivity of anal cytology in detecting anal intraepithelial neoplasia.

    Science.gov (United States)

    ElNaggar, Adam C; Santoso, Joseph T; Xie, Huiwen Bill

    2012-02-01

    To identify factors that may contribute to poor sensitivity of anal cytology in contrast to the sensitivity of anoscopy in heterosexual women. We analyzed 324 patients with biopsy confirmed diagnosis of genital intraepithelial neoplasia (either vulva, vaginal, or cervical) from 2006 to 2011 who underwent both anal cytology and anoscopy. Cytology, anoscopy, and biopsy results were recorded. Biopsy specimens underwent independent analysis for quality of specimen. Also, biopsy specimens were analyzed for characteristics that may contribute to correlation, or lack thereof, between anal cytology and anoscopic directed biopsy. 133 (41%) patients had abnormal anoscopy and underwent directed biopsy. 120 patients with normal anal cytology had anoscopy directed biopsies, resulting in 58 cases of AIN (sensitivity 9.4%; 0.039-0.199). This cohort was noted to have extensive keratosis covering the entire dysplastic anal lesion. 18 patients yielded abnormal anal cytology. Of these patients, 13 had anoscopic directed biopsies revealing 6 with AIN and absent keratosis (specificity 88.6%; 0.78-0.95). The κ statistic for anal cytology and anoscopy was -0.0213 (95% CI=-0.128-0.086). Keratosis reduces the sensitivity of anal cytology. Furthermore, anal cytology poorly correlates with anoscopy in the detection of AIN (κ statistic=-0.0213). Copyright © 2011 Elsevier Inc. All rights reserved.

  11. Arterial Stiffness is an Independent Risk Factor for Anemia After Percutaneous Native Kidney Biopsy

    Directory of Open Access Journals (Sweden)

    Keiko Tanaka

    2017-05-01

    Full Text Available Background/Aims: Bleeding is the most common complication after renal biopsy. Although numerous predictors of bleeding have been reported, it remains unclear whether arterial stiffness affects bleeding complications. Method: We performed an observational study of the renal biopsies performed in our division over an approximately 6-year period (May 2010 to May 2016. The clinical and laboratory factors were analyzed to reveal the risk factors associated with bleeding, with a focus on anemia (defined as a ≥10% decrease in hemoglobin [Hb] after biopsy. The brachial-ankle pulse wave velocity (baPWV was measured to evaluate arterial stiffness. Results: This study included 462 patients (male, n=244; female, n=218. Anemia (defined above was observed in 54 patients (11.7%. The risk of anemia was higher in women, older patients, and patients with lower serum albumin, lower eGFR and lower diastolic blood pressure after biopsy. We then performed a further analysis of 187 patients whose baPWV data were available. Multivariate analysis revealed that a higher baPWV was an independent risk factor for anemia. ROC analysis for predicting anemia found that a baPWV value of 1839 cm/s had the best performance (AUC 0.689. Conclusion: An increased baPWV may be a more valuable predictor of bleeding than any of the other reported risk factors.

  12. Improved quality of patient care through routine second review of histopathology specimens prior to multidisciplinary meetings.

    Science.gov (United States)

    Kuijpers, Chantal C H J; Burger, Gerard; Al-Janabi, Shaimaa; Willems, Stefan M; van Diest, Paul J; Jiwa, Mehdi

    2016-10-01

    Double reading may be a valuable tool for improving quality of patient care by identifying diagnostic errors before final sign-out, but standard double reading would significantly increase costs of pathology. We assessed the added value of intradepartmental routine double reading of histopathology specimens prior to multidisciplinary meetings. Diagnoses, treatment plans and prognoses of patients are often discussed at multidisciplinary meetings. As part of the daily routine, all pathology specimens to be discussed at upcoming multidisciplinary meetings undergo prior intradepartmental double reading. We identified all histopathology specimens from 2013 that underwent such double reading and determined major and minor discordance rates based on clinical relevance between the initial and consensus sign-out diagnoses. We included 6796 histopathology specimens that underwent double reading, representing approximately 8% of all histopathology cases at our institution in 2013. Double reading diagnoses were concordant in 6566 specimens (96.6%). Major and minor discordances were observed in 60 (0.9%) and 170 (2.5%) specimens, respectively. Urology specimens had significantly more discordances than other tissues of origin, Gleason grading of prostate cancer biopsies being the most frequent diagnostic problem. Furthermore, premalignant and malignant cases showed significantly higher discordance rates than the rest. The vast majority (90%) of discordances represented changes within the same diagnostic category (eg, malignant to malignant). Routine double reading of histopathology specimens prior to multidisciplinary meetings prevents diagnostic errors. It resulted in about 1% discordant diagnoses of potential clinical significance, indicating that second review is worthwhile in terms of patient safety and quality of patient care. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  13. Comparison of Battery-Powered and Manual Bone Biopsy Systems for Core Needle Biopsy of Sclerotic Bone Lesions.

    Science.gov (United States)

    Cohen, Micah G; McMahon, Colm J; Kung, Justin W; Wu, Jim S

    2016-05-01

    The purpose of this study was to compare manual and battery-powered bone biopsy systems for diagnostic yield and procedural factors during core needle biopsy of sclerotic bone lesions. A total of 155 consecutive CT-guided core needle biopsies of sclerotic bone lesions were performed at one institution from January 2006 to November 2014. Before March 2012, lesions were biopsied with manual bone drill systems. After March 2012, most biopsies were performed with a battery-powered system and either noncoaxial or coaxial biopsy needles. Diagnostic yield, crush artifact, CT procedure time, procedure radiation dose, conscious sedation dose, and complications were compared between the manual and battery-powered core needle biopsy systems by Fisher exact test and t test. One-way ANOVA was used for subgroup analysis of the two battery-powered systems for procedure time and radiation dose. The diagnostic yield for all sclerotic lesions was 60.0% (93/155) and was significantly higher with the battery-powered system (73.0% [27/37]) than with the manual systems (55.9% [66/118]) (p = 0.047). There was no significant difference between the two systems in terms of crush artifact, procedure time, radiation dose, conscious sedation administered, or complications. In subgroup analysis, the coaxial battery-powered biopsies had shorter procedure times (p = 0.01) and lower radiation doses (p = 0.002) than the coaxial manual systems, but the noncoaxial battery-powered biopsies had longer average procedure times and higher radiation doses than the coaxial manual systems. In biopsy of sclerotic bone lesions, use of a battery-powered bone drill system improves diagnostic yield over use of a manual system.

  14. Sonographically guided core biopsy of the breast: comparison of 14-gauge automated gun and 11-gauge directional vacuum-assisted biopsy methods

    International Nuclear Information System (INIS)

    Cho, Nariya; Moon, Woo Kyung; Cha, Joo Hee

    2005-01-01

    To compare the outcomes of 14-gauge automated biopsy and 11-gauge vacuum-assisted biopsy for the sonographically guided core biopsies of breast lesions. We retrospectively reviewed all sonographically guided core biopsies performed from January 2002 to February 2004. The sonographically guided core biopsies were performed with using a 14-gauge automated gun on 562 breast lesions or with using an 11-gauge vacuum-assisted device on 417 lesions. The histologic findings were compared with the surgical, imaging and follow-up findings. The histologic underestimation rate, the repeat biopsy rate and the false negative rates were compared between the two groups. A repeat biopsy was performed on 49 benign lesions because of the core biopsy results of the high-risk lesions (n=24), the imaging-histologic discordance (n=5), and the imaging findings showing disease progression (n=20). The total underestimation rates, according to the biopsy device, were 55% (12/22) for the 14-gauge automated gun biopsies and 36% (8/22) for the 11-gauge vacuum-assisted device (ρ = 0.226). The atypical ductal hyperplasia (ADH) underestimation (i.e., atypical ductal hyperplasia at core biopsy and carcinoma at surgery) was 58% (7/12) for the 14-gauge automated gun biopsies and 20% (1/5) for the 11-gauge vacuum-assisted biopsies. The ductal carcinoma in situ (DCIS) underestimation rate (i.e., ductal carcinoma in situ upon core biopsy and invasive carcinoma found at surgery) was 50% (5/10) for the 14-gauge automated gun biopsies and 41% (7/17) for the 11-gauge vacuum-assisted biopsies. The repeat biopsy rates were 6% (33/562) for the 14-gauge automated gun biopsies and 3.5% (16/417) for the 11-gauge vacuum-assisted biopsies. Only 5 (0.5%) of the 979 core biopsies were believed to have missed the malignant lesions. The false-negative rate was 3% (4 of 128 cancers) for the 14-gauge automated gun biopsies and 1% (1 of 69 cancers) for the 11-gauge vacuum-assisted biopsies. The outcomes of the

  15. Immunohistological expression of HIF-1α, GLUT-1, Bcl-2 and Ki-67 in consecutive biopsies during chemoradiotherapy in patients with rectal cancer

    DEFF Research Database (Denmark)

    Havelund, Birgitte Mayland; Sørensen, Flemming Brandt; Pløen, John

    2013-01-01

    receiving preoperative CRT (>50.4 Gy and Uracil/Tegafur). Immunohistological expressions of HIF-1α, GLUT-1, Bcl-2 and Ki-67 were investigated in biopsies taken before treatment, after 2, 4 and 6 weeks of CRT and in specimens from the operation. Decreasing expressions of HIF-1α, Bcl-2 and Ki-67 were observed...

  16. Comparison of diagnostic quality of kidney biopsy obtained using 16g and 18g needles in patients with diffuse renal disease

    Directory of Open Access Journals (Sweden)

    Komal Arora

    2012-01-01

    Full Text Available To determine the diagnostic quality and complication rates of 16G and 18G needles in biopsy of the kidney, we performed renal biopsy using a biopsy gun under ultrasound guidance in 50 patients who were prospectively and evenly assigned to one of the two needle biopsy methods from April 2007 until May 2008. Two cores of renal biopsy specimen were obtained in each case and subjected to histopathological and immunoflourescence (IF examination. Pain associated with the procedure was assessed using a visual analog scale. The number of glomeruli retrieved using the 16G needle ranged from 0 to 30 (mean 9.42 ± 5.5 and those retrieved using 18G needle ranged from 0 to 19 (mean 7.72 ± 4.4, P <0.05. The quality of biopsy was poorer with 18G needle as compared with 16G needles because of a higher amount of fragmentation and crushing artifact. There was no difference in the compli-cation rates between the two needles (2% each. The 16G needle was associated with significantly more pain than the 18G needle. We conclude that our study demonstrates the benefit of the larger 16G needle in providing more tissue and glomeruli, which is more diagnostically useful. However, the use of 16G needle was associated with significantly more pain than the 18G needle, and may be a better compromise for diagnostic usefulness and patient acceptability.

  17. Relationship of endometrial thickness detected by transvaginal sonography with the results of endometrial biopsy & hysteroscopic directed biopsy in post menopausal bleeding

    Directory of Open Access Journals (Sweden)

    Vahid Dastjerdi M

    2008-05-01

    Full Text Available Background: Post-menopausal hemorrhage is one of the most common complains in gynecologic clinics. More than 60% of these cases have abnormal findings in diagnostic work ups. There is contraversy about the best diagnostic method for evaluating post-menopausal hemorrhage. The aim of this study was to evaluate the results of Trans-Vaginal Ultrasonography and compare its result to ones derived from direct endometrial biopsy and Hysteroscopy findings.Methods: In a cross-sectional study, menopausal women who attended the outpatient clinic of Arash Hospital, Tehran University of medical Sciences, from April 2005 to March 2006 with the complain of hemorrhage were evaluated. In all of these patients, after getting informed consent, Trans-Vaginal Ultrasonography, Dilatation and Curettage and Hysteroscopy were performed.Results: The total number of 90 women was recruited to the study with the age range of 41-80 years. The mean age of participants was 53.84 ± 6 years and 4.3 ± 5.1 years had passed from their menopause. The mean thickness of endometrium, measured by Trans Vaginal ultrasonography was 6.25 ± 3.7 millimeter. In the biopsy derived specimens, the most finding pathological presentation was atrophy (48.9% and the Proliferative endometrium had the second prevalence (36.7%. Atrophy (44.4% and Proliferative endometrium (33.3% were the most prevalent finding in Hysteroscopy. There was a significant difference in endometrial thickness between groups of different pathological findings. A significant difference in endometrial thickness was also seen between groups with different Hysteroscopic finding. By grouping the data according to endometrial thickness, it became evident that endometrial thickness can predict the outcome of endometrial biopsy and Hysteroscopic finding efficiently. We used ROC curves to find the best grouping threshold for endometrial thickness to achieve the best sensitivity and specificity.Conclusion: Measuring the endometrial

  18. No need for biopsies

    DEFF Research Database (Denmark)

    Gjødsbøl, Kristine; Skindersoe, Mette E; Christensen, Jens Jørgen

    2011-01-01

    The aim of the study was to compare three sampling techniques used in routine diagnostics to identify the microbiota in chronic venous leg ulcers. A total of 46 patients with persisting venous leg ulcers were included in the study. At inclusion, swab, biopsy and filter paper pad samples were...... collected. After 4 weeks, additional biopsy and filter paper pad samples were collected. Bacteria were isolated and identified at species level by standard methods. The most common bacterial species detected was Staphylococcus aureus found in 89% of the ulcers. No methicillin-resistant S. aureus isolates...... species present in chronic wounds, thus avoiding complications during and after biopsy sampling....

  19. Magnetic resonance imaging-guided biopsies may improve diagnosis in biopsy-naive men with suspicion of prostate cancer

    DEFF Research Database (Denmark)

    Winther, Mads Dochedahl; Balslev, Ingegerd; Boesen, Lars

    2017-01-01

    INTRODUCTION: The purpose of this pilot study was to investigate whether a short prostate biparametric magnetic resonance imaging (bp-MRI) protocol provides a valuable diagnostic addition for biopsy guidance in biopsy-naive men with a suspicion of prostate cancer (PCa). METHODS: A total of 62...... biopsy-naive patients referred to a systematic transrectal ultrasound biopsy (TRUS-bx) due to suspicion of PCa were prospectively enrolled. Bp-MRI was performed before biopsy. All lesions were scored according to the modified Prostate Imaging Reporting and Data System (PI-RADS) version 2. All patients...... underwent TRUS-bx followed by bp-MRI-guided biopsies (bp-MRI-bx) under MRI/TRUS image fusion from any bp-MRI suspicious lesions not obviously targeted by TRUS-bx. RESULTS: PCa was found in 42 (68%) and 32 (52%) patients by TRUS-bx and bp-MRI-bx, respectively. Bp-MRI-bx de-tected PCa in one patient who had...

  20. Incremental diagnostic value of targeted biopsy using mpMRI-TRUS fusion versus 14-fragments prostatic biopsy. A prospective controlled study

    International Nuclear Information System (INIS)

    Mariotti, Guilherme C.; Falsarella, Priscila M.; Garcia, Rodrigo G.; Queiroz, Marcos R.G.; Lemos, Gustavo C.; Baroni, Ronaldo H.

    2018-01-01

    To compare the incremental diagnostic value of targeted biopsy using real-time multiparametric magnetic resonance imaging and transrectal ultrasound (mpMRI-TRUS) fusion to conventional 14-cores biopsy. Uni-institutional, institutional review board (IRB) approved prospective blinded study comparing TRUS-guided random and targeted biopsy using mpMRI-TRUS fusion, in 100 consecutive men. We included men with clinical-laboratorial suspicious for prostate cancer and Likert score ≥ 3 mp-MRI. Patients previously diagnosed with prostate cancer were excluded. All patients were submitted to 14-cores TRUS-guided biopsy (mpMRI data operator-blinded), followed by targeted biopsy using mpMRI-TRUS fusion. There was an overall increase in cancer detection rate, from 56% with random technique to 62% combining targeted biopsy using mpMRI-TRUS fusion; incremental diagnosis was even more relevant for clinically significant lesions (Gleason ≥ 7), diagnosing 10% more clinically significant lesions with fusion biopsy technique. Diagnosis upgrade occurred in 5 patients that would have negative results in random biopsies and had clinically significant tumours with the combined technique, and in 5 patients who had the diagnosis of significant tumours after fusion biopsy and clinically insignificant tumours in random biopsies(p=0.0010). Targeted biopsy using mpMRI-TRUS fusion has incremental diagnostic value in comparison to conventional random biopsy, better detecting clinically significant prostate cancers. (orig.)

  1. Incremental diagnostic value of targeted biopsy using mpMRI-TRUS fusion versus 14-fragments prostatic biopsy. A prospective controlled study

    Energy Technology Data Exchange (ETDEWEB)

    Mariotti, Guilherme C.; Falsarella, Priscila M.; Garcia, Rodrigo G.; Queiroz, Marcos R.G. [Hospital Israelita Albert Einstein, Department of Interventional Radiology, Sao Paulo (Brazil); Lemos, Gustavo C. [Hospital Israelita Albert Einstein, Department of Urology, Sao Paulo (Brazil); Baroni, Ronaldo H. [Hospital Israelita Albert Einstein, Department of Radiology, Sao Paulo (Brazil)

    2018-01-15

    To compare the incremental diagnostic value of targeted biopsy using real-time multiparametric magnetic resonance imaging and transrectal ultrasound (mpMRI-TRUS) fusion to conventional 14-cores biopsy. Uni-institutional, institutional review board (IRB) approved prospective blinded study comparing TRUS-guided random and targeted biopsy using mpMRI-TRUS fusion, in 100 consecutive men. We included men with clinical-laboratorial suspicious for prostate cancer and Likert score ≥ 3 mp-MRI. Patients previously diagnosed with prostate cancer were excluded. All patients were submitted to 14-cores TRUS-guided biopsy (mpMRI data operator-blinded), followed by targeted biopsy using mpMRI-TRUS fusion. There was an overall increase in cancer detection rate, from 56% with random technique to 62% combining targeted biopsy using mpMRI-TRUS fusion; incremental diagnosis was even more relevant for clinically significant lesions (Gleason ≥ 7), diagnosing 10% more clinically significant lesions with fusion biopsy technique. Diagnosis upgrade occurred in 5 patients that would have negative results in random biopsies and had clinically significant tumours with the combined technique, and in 5 patients who had the diagnosis of significant tumours after fusion biopsy and clinically insignificant tumours in random biopsies(p=0.0010). Targeted biopsy using mpMRI-TRUS fusion has incremental diagnostic value in comparison to conventional random biopsy, better detecting clinically significant prostate cancers. (orig.)

  2. Characterization of Human Cytomegalovirus Genome Diversity in Immunocompromised Hosts by Whole-Genome Sequencing Directly From Clinical Specimens.

    Science.gov (United States)

    Hage, Elias; Wilkie, Gavin S; Linnenweber-Held, Silvia; Dhingra, Akshay; Suárez, Nicolás M; Schmidt, Julius J; Kay-Fedorov, Penelope C; Mischak-Weissinger, Eva; Heim, Albert; Schwarz, Anke; Schulz, Thomas F; Davison, Andrew J; Ganzenmueller, Tina

    2017-06-01

    Advances in next-generation sequencing (NGS) technologies allow comprehensive studies of genetic diversity over the entire genome of human cytomegalovirus (HCMV), a significant pathogen for immunocompromised individuals. Next-generation sequencing was performed on target enriched sequence libraries prepared directly from a variety of clinical specimens (blood, urine, breast milk, respiratory samples, biopsies, and vitreous humor) obtained longitudinally or from different anatomical compartments from 20 HCMV-infected patients (renal transplant recipients, stem cell transplant recipients, and congenitally infected children). De novo-assembled HCMV genome sequences were obtained for 57 of 68 sequenced samples. Analysis of longitudinal or compartmental HCMV diversity revealed various patterns: no major differences were detected among longitudinal, intraindividual blood samples from 9 of 15 patients and in most of the patients with compartmental samples, whereas a switch of the major HCMV population was observed in 6 individuals with sequential blood samples and upon compartmental analysis of 1 patient with HCMV retinitis. Variant analysis revealed additional aspects of minor virus population dynamics and antiviral-resistance mutations. In immunosuppressed patients, HCMV can remain relatively stable or undergo drastic genomic changes that are suggestive of the emergence of minor resident strains or de novo infection. © The Author 2017. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail journals.permissions@oup.com.

  3. Outcomes of ultrasound guided renal mass biopsies.

    Science.gov (United States)

    Sutherland, Edward L; Choromanska, Agnieszka; Al-Katib, Sayf; Coffey, Mary

    2018-06-01

    The purpose of this study was to evaluate the rate of nondiagnostic ultrasound-guided renal mass biopsies (RMBs) at our institution and to determine what patient, procedural, and focal renal mass (FRM) factors were associated with nondiagnostic ultrasound-guided RMBs. Eighty-two ultrasound-guided renal mass biopsies performed between January 2014 and October 2016 were included in our study. Biopsy outcomes (diagnostic vs. nondiagnostic) and patient, procedural, and FRM characteristics were retrospectively reviewed and recorded. Univariate statistical analyses were performed to identify biopsy characteristics that were indicative of nondiagnostic biopsy. Ultrasound-guided RMBs were diagnostic in 70 out of 82 cases (85%) and non-diagnostic in 12 cases (15%). Among the diagnostic biopsies, 54 (77%) were malignant cases, 94% of which were renal cell carcinoma (RCC). Of the 12 nondiagnostic cases, the final diagnosis was RCC in 4 cases and angiomyolipoma in one case; seven of the nondiagnostic cases were lost to follow-up. A weak association (p = 0.04) was found between the number of needle passes and the biopsy outcome. None of the remaining collected RMB characteristics showed a significant correlation with a diagnostic or nondiagnostic RMB. Six patients (7%) experienced complications. Ultrasound-guided renal mass biopsy is a safe and effective method for the diagnosis of renal masses with a low rate of nondiagnostic outcomes. A nondiagnostic biopsy should not be treated as a surrogate for a diagnosis since a significant number of patients with nondiagnostic biopsies have subsequently been shown to have renal malignancies. Repeat biopsy should be considered in such cases.

  4. Surface staining of small intestinal biopsies

    DEFF Research Database (Denmark)

    Poulsen, Steen Seier

    1977-01-01

    Small intestinal biopsies are most often by routine examined under a stereo-microscope, prior to embedding for histological examination. This is done in order to get a view of the appearance of the mucosal pattern, especially villus configuration. The distinctness of the surface pattern however......, is improved considerably if the biopsies are stained with Alcian Green and/or PAS before they are examined. In the present paper a detailed description is given of staining of small intestinal biopsies as whole mounts. The difference between the unstained and the stained biopsies is illustrated by a few...

  5. Needle muscle biopsy and its application

    Directory of Open Access Journals (Sweden)

    Meng-long CHEN

    2015-07-01

    Full Text Available Needle muscle biopsy is a straightforward and reliable minimally-invasive technique. During the past century, the needle biopsy can provide adequate samples and the technique has gradually gained wider acceptance. Compared with open biopsy, needle biopsy is less traumatic, with low rate of complications, and is suitable for the identifications and evaluations of muscular dystrophy, inflammatory myopathies and systemic diseases involving muscles, specially for infants and young children. Domestic insiders should be encouraged to apply this technique. DOI: 10.3969/j.issn.1672-6731.2015.06.003 

  6. Optical biopsy of tissue with Mueller polarimetry: theory and experiments (Conference Presentation)

    Science.gov (United States)

    Novikova, Tatiana; Meglinski, Igor; Garcia-Caurel, Enric; Bykov, Alexander; Rehbinder, Jean; Deby, Stanislas; Vizet, Jérémy; Pierangelo, Angelo; Moreau, François; Validire, Pierre; Benali, Abdelali; Gayet, Brice; Teig, Benjamin; Nazac, André; Ossikovski, Razvigor

    2017-02-01

    The rise of optical biopsy as an alternative to classical biopsy is dictated by ongoing technological progress: any type of measurements has to be fast, precise, non-invasive and implemented in-vivo. The use of polarized light for optical biopsy has a long history. As Mueller-Stokes formalism provides the most complete description of polarized light interaction with any type of sample (even depolarizing one) we explored the capabilities of in-house multi-wavelength Mueller imaging polarimeter for the detection of pre-malignancy and malignancy. Our studies were performed with both scattering phantom tissues (in transmission configuration) and specimens of human colon and uterine cervix (in backscattering configuration). For the interpretation of measurement results we decomposed Mueller matrix of a sample into product of elementary Mueller matrices of homogeneous diattenuator, retarder, and depolarizer. This phenomenological approach does not require the exact solution of Maxwell equations and provides the "effective" values of polarimetric properties of sample. Exploring differential Mueller matrix formalism for fluctuating medium we showed that depolarization in homogeneous turbid medium varied parabolically with the pathlength of transmitted light, while the standard deviation of elementary polarization properties of medium depends linearly on the concentration of scatterers. Neither scattering phantoms nor human tissue possessed any measurable diattenuation in backscattering configuration. The polarimetric images of tissue depolarization power, scalar birefringence and orientation of optical axis were compared with the analysis of histological slides. The spectral dependence of depolarization power and scalar birefringence values ascertained the potential of imaging Mueller polarimetry to discriminate healthy and diseased tissue zones.

  7. 20 CFR 718.106 - Autopsy; biopsy.

    Science.gov (United States)

    2010-04-01

    ... 20 Employees' Benefits 3 2010-04-01 2010-04-01 false Autopsy; biopsy. 718.106 Section 718.106... PNEUMOCONIOSIS Criteria for the Development of Medical Evidence § 718.106 Autopsy; biopsy. (a) A report of an autopsy or biopsy submitted in connection with a claim shall include a detailed gross macroscopic and...

  8. Surgical Excision of Benign Papillomas Diagnosed with Core Biopsy: A Community Hospital Approach

    International Nuclear Information System (INIS)

    Rozentsvayg, Eka; Carver, Kristen; Borkar, Sunita; Mathew, Melvy; Enis, Sean; Friedman, Paul

    2011-01-01

    Our goal was to assess the value of surgical excision of benign papillomas of the breast diagnosed on percutaneous core biopsy by determining the frequency of upgrade to malignancies and high risk lesions on a final surgical pathology. We reviewed 67 patients who had biopsies yielding benign papilloma and underwent subsequent surgical excision. Surgical pathology of the excised lesions was compared with initial core biopsy pathology results. 54 patients had concordant benign core and excisional pathology. Cancer (ductal carcinoma in situ and invasive ductal carcinoma) was diagnosed in five (7%) patients. Surgery revealed high-risk lesions in 8 (12%) patients, including atypical ductal hyperplasia, atypical lobular hyperplasia, and lobular carcinoma in situ. Cancer and high risk lesions accounted for 13 (19%) upstaging events from benign papilloma diagnosis. Our data suggests that surgical excision is warranted with core pathology of benign papilloma

  9. Sonographically guided percutaneous muscle biopsy in diagnosis of neuromuscular disease: a useful alternative to open surgical biopsy.

    Science.gov (United States)

    O'Sullivan, Paul J; Gorman, Grainne M; Hardiman, Orla M; Farrell, Michael J; Logan, P Mark

    2006-01-01

    The purpose of this study was to evaluate the feasibility of sonographically guided percutaneous muscle biopsy in the investigation of neuromuscular disorders. Sonographically guided percutaneous needle biopsy of skeletal muscle was performed with a 14-gauge core biopsy system in 40 patients over a 24-month period. Patients were referred from the Department of Neurology under investigation for neuromuscular disorders. Sonography was used to find suitable tissue and to avoid major vascular structures. A local anesthetic was applied below skin only. A 3- to 4-mm incision was made. Three 14-gauge samples were obtained from each patient. All samples were placed on saline-dampened gauze and sent for neuropathologic analysis. As a control, we retrospectively assessed results of the 40 most recent muscle samples acquired via open surgical biopsy. With the use of sonography, 32 (80%) of 40 patients had a histologic diagnosis made via percutaneous needle biopsy. This included 26 (93%) of 28 patients with acute muscular disease and 6 (50%) of 12 patients with chronic disease. In the surgical group (all acute disease), 38 (95%) of 40 patients had diagnostic tissue attained. Sonographically guided percutaneous 14-gauge core skeletal muscle biopsy is a useful procedure, facilitating diagnosis in acute muscular disease. It provides results comparable with those of open surgical biopsy in acute muscular disease. It may also be used in chronic muscular disease but repeated or open biopsy may be needed.

  10. Are concurrent systematic cores needed at the time of targeted biopsy in patients with prior negative prostate biopsies?

    Science.gov (United States)

    Albisinni, S; Aoun, F; Noel, A; El Rassy, E; Lemort, M; Paesmans, M; van Velthoven, R; Roumeguère, T; Peltier, A

    2018-01-01

    MRI-guided targeted biopsies are advised in patients who have undergone an initial series of negative systematic biopsies, in whom prostate cancer (PCa) suspicion remains elevated. The aim of the study was to evaluate whether, in men with prior negative prostate biopsies, systematic cores are also warranted at the time of an MRI-targeted repeat biopsy. We enrolled patients with prior negative biopsy undergoing real time MRI/TRUS fusion guided prostate biopsy at our institute between 2014 and 2016. Patients with at least one index lesion on multiparametric MRI were included. All eligible patients underwent both systematic random biopsies (12-14 cores) and targeted biopsies (2-4 cores). The study included 74 men with a median age of 65 years, PSA level of 9.27ng/mL, and prostatic volume of 45ml. The overall PCa detection rate and the clinically significant cancer detection rate were 56.7% and 39.2%, respectively. Targeted cores demonstrated similar clinically significant PCa detection rate compared to systematic cores (33.8% vs. 28.4%, P=0.38) with significantly less tissue sampling. Indeed, a combination approach was significantly superior to a targeted-only in overall PCa detection (+16.7% overall detection rate, P=0.007). Although differences in clinically significant PCa detection were statistically non-significant (P=0.13), a combination approach did allow detecting 7 extra clinically significant PCas (+13.8%). In patients with elevated PSA and prior negative biopsies, concurrent systematic sampling may be needed at the time of targeted biopsy in order to maximize PCa detection rate. Larger studies are needed to validate our findings. 4. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  11. A new method in thoracoscopic inferior mediastinal lymph node biopsy: a case report

    Directory of Open Access Journals (Sweden)

    Sanlı Maruf

    2009-11-01

    Full Text Available Abstract Introduction We performed video-thoracoscopy with a video-mediastinoscope to conduct a mediastinal lymph node biopsy. Here, we discuss the various advantages of the method. Case presentation A 56-year-old Turkish Caucasian man had been complaining of dyspnea on exertion, hacking cough, fever and continuous sweating for one and a half months. Thoracic computed tomography revealed enlarged paratracheal and aorticopulmonary lymph nodes, the largest of which was 1 cm in diameter and reticulo-micronodular interstitial infiltration extending symmetrically to the pleural surfaces in both pulmonary perihilar areas. Computed tomography supported positron emission tomography showed increased fluorodeoxyglucose retention in lymph nodes in both hilar areas (10R and 10L (maximum standardized uptake values 5.6 and 5.7, and in the right lower paratracheal (4R (maximum standardized uptake value 4.1 and right para-esophageal (8 (maximum standardized uptake value 8.9 lymph nodes. Pathological examination of the right lymph node number 8 biopsy using the video-mediastinoscope revealed the presence of granulomatous inflammation. No problems were observed during the postoperative period. Conclusion The use of the video-mediastinoscope for inferior lymph node biopsy in thoracoscopy is an easy, safe and practical method, especially in patients with pleural adhesions.

  12. Mammographic scar for stereotaxic biopsy

    International Nuclear Information System (INIS)

    Guzman Tattis; Hincapie U, Ana Lucia; Patino P, Jairo Hernando

    1997-01-01

    It is reported the case of 56 years old woman who underwent a stereotactic biopsy because of having a circumscribed breast nodule. The histologic diagnosis was benign. After six months, during the mammographic control, it was noticed that the nodule showed irregular contours, because of that a surgical biopsy was performed. The histopathology was reported as benign. it is considered then, that the mammographic changes observed in the mammographic control are due to scar phenomenon after stereotactic biopsy. This findings has not been reported previously

  13. MRI-Targeted or Standard Biopsy for Prostate-Cancer Diagnosis.

    Science.gov (United States)

    Kasivisvanathan, Veeru; Rannikko, Antti S; Borghi, Marcelo; Panebianco, Valeria; Mynderse, Lance A; Vaarala, Markku H; Briganti, Alberto; Budäus, Lars; Hellawell, Giles; Hindley, Richard G; Roobol, Monique J; Eggener, Scott; Ghei, Maneesh; Villers, Arnauld; Bladou, Franck; Villeirs, Geert M; Virdi, Jaspal; Boxler, Silvan; Robert, Grégoire; Singh, Paras B; Venderink, Wulphert; Hadaschik, Boris A; Ruffion, Alain; Hu, Jim C; Margolis, Daniel; Crouzet, Sébastien; Klotz, Laurence; Taneja, Samir S; Pinto, Peter; Gill, Inderbir; Allen, Clare; Giganti, Francesco; Freeman, Alex; Morris, Stephen; Punwani, Shonit; Williams, Norman R; Brew-Graves, Chris; Deeks, Jonathan; Takwoingi, Yemisi; Emberton, Mark; Moore, Caroline M

    2018-05-10

    Multiparametric magnetic resonance imaging (MRI), with or without targeted biopsy, is an alternative to standard transrectal ultrasonography-guided biopsy for prostate-cancer detection in men with a raised prostate-specific antigen level who have not undergone biopsy. However, comparative evidence is limited. In a multicenter, randomized, noninferiority trial, we assigned men with a clinical suspicion of prostate cancer who had not undergone biopsy previously to undergo MRI, with or without targeted biopsy, or standard transrectal ultrasonography-guided biopsy. Men in the MRI-targeted biopsy group underwent a targeted biopsy (without standard biopsy cores) if the MRI was suggestive of prostate cancer; men whose MRI results were not suggestive of prostate cancer were not offered biopsy. Standard biopsy was a 10-to-12-core, transrectal ultrasonography-guided biopsy. The primary outcome was the proportion of men who received a diagnosis of clinically significant cancer. Secondary outcomes included the proportion of men who received a diagnosis of clinically insignificant cancer. A total of 500 men underwent randomization. In the MRI-targeted biopsy group, 71 of 252 men (28%) had MRI results that were not suggestive of prostate cancer, so they did not undergo biopsy. Clinically significant cancer was detected in 95 men (38%) in the MRI-targeted biopsy group, as compared with 64 of 248 (26%) in the standard-biopsy group (adjusted difference, 12 percentage points; 95% confidence interval [CI], 4 to 20; P=0.005). MRI, with or without targeted biopsy, was noninferior to standard biopsy, and the 95% confidence interval indicated the superiority of this strategy over standard biopsy. Fewer men in the MRI-targeted biopsy group than in the standard-biopsy group received a diagnosis of clinically insignificant cancer (adjusted difference, -13 percentage points; 95% CI, -19 to -7; Pprostate cancer who had not undergone biopsy previously. (Funded by the National Institute for

  14. Frequency of fungal infection in biopsies of oral mucosal lesions: A prospective hospital-based study

    Directory of Open Access Journals (Sweden)

    Thimmarasa Venkappa Bhovi

    2015-01-01

    Full Text Available Aims and Objectives: To determine the frequency and common site of fungal infection in biopsies of oral mucosal lesions and also to detect the lesions most likely to be infected with fungal infection. Materials and Methods: A total of 100 patients with oral mucosal lesions were advised routine hematological examination followed by incisional biopsy under local anesthesia. The specimen were fixed in 10% neutral buffered formalin and processed. One section from the specimen was stained with hematoxylin and eosin staining for histopathological diagnosis of the lesion and a second section was stained with Periodic acid-Schiff (PAS stain for detection of fungal infection. Results: Out of the 100 patients, the most common mucosal lesion encountered was carcinoma (56% followed by lesions with dysplastic changes (28%, benign lesions (9%, squamous papilloma (2% and oral submucous fibrosis (5%. The most common anatomic location affected by the mucosal lesions were buccal mucosa, followed by the tongue, gingiva, maxillary tuberosity and floor of the mouth with values of 73%, 16%, 6%, 4% and 1%, respectively. Squamous papilloma had the highest positive association with fungal infection (100% followed by lesions with dysplastic changes (17.9% and carcinoma (8.9%. The maximum fungal positive association was encountered in the mucosal lesions over the tongue (18.7% followed by the buccal mucosa (12.3%. Conclusion: There is statistically significant association of fungal infection with dysplastic lesions and papilloma with the tongue and buccal mucosa as the most common sites. Hence a PAS stain should be performed whenever epithelial dysplasia on the tongue and buccal mucosa is diagnosed.

  15. Coeliac disease: to biopsy or not?

    Science.gov (United States)

    Reilly, Norelle R; Husby, Steffen; Sanders, David S; Green, Peter H R

    2018-01-01

    Coeliac disease is increasingly recognized as a global problem in both children and adults. Traditionally, the findings of characteristic changes of villous atrophy and increased intraepithelial lymphocytosis identified in duodenal biopsy samples taken during upper gastrointestinal endoscopy have been required for diagnosis. Although biopsies remain advised as necessary for the diagnosis of coeliac disease in adults, European guidelines for children provide a biopsy-sparing diagnostic pathway. This approach has been enabled by the high specificity and sensitivity of serological testing. However, these guidelines are not universally accepted. In this Perspective, we discuss the pros and cons of a biopsy-avoiding pathway for the diagnosis of coeliac disease, especially in this current era of the call for more biopsies, even from the duodenal bulb, in the diagnosis of coeliac disease. In addition, a contrast between paediatric and adult guidelines is presented.

  16. Accuracy of pre-operative hysteroscopic guided biopsy for predicting final pathology in uterine malignancies.

    Science.gov (United States)

    Martinelli, Fabio; Ditto, Antonino; Bogani, Giorgio; Signorelli, Mauro; Chiappa, Valentina; Lorusso, Domenica; Haeusler, Edward; Raspagliesi, Francesco

    2017-07-01

    To evaluate concordance (C) between pre-operative hysteroscopic-directed sampling and final pathology in uterine cancers. A retrospective cross-sectional evaluation of prospectively collected data of women who underwent hysterectomy for uterine malignancies and a previous hysteroscopic-guided biopsy was performed. Diagnostic concordance between pre-operative (hysteroscopic biopsy) and postoperative (uterine specimen) histology was evaluated. In endometrioid-endometrial cancers cases Kappa (k) statistics was applied to evaluate agreement for grading (G) between the preoperative and final pathology. A total 101 hysterectomies for uterine malignancies were evaluated. There were 23 non-endometrioid cancers: 7 serous (C:5/7, 71.4%); 10 carcinosarcomas (C:7/10, 70%, remaining 3 cases only epithelial component diagnosed); 3 clear cell (C:3/3, 100%); 3 sarcomas (C:3/3, 100%). In 78 cases an endometrioid endometrial cancer was found. In 63 cases there was a histological C (63/78, 80.8%) between hysteroscopic-guided biopsy and final pathology, while in 15 cases (19.2%) only hyperplasia (with/without atypia) was found preoperatively. Overall accuracy to detect endometrial cancer was 80.2%. In 50 out of 63 endometrial cancers (79.4%) grading was concordant. The overall level of agreement between preoperative and postoperative grading was "substantial" according to Kappa (k) statistics (k 0.64; 95% CI: 0.449-0.83; p < 0.001), as well as for G1 (0.679; 95% CI: 0.432-0.926; p < 0.001) and G3 (0.774; 94% CI: 0.534-1; p < 0.001), while for G2 (0.531; 95% CI: 0.286-0.777; p < 0.001) it was moderate. In our series we found an 80% C between pre-operative hysteroscopic-guided biopsy and final pathology, in uterine malignancies. Moreover, hysteroscopic biopsy accurately predicted endometrial cancer in 80% of cases and "substantially" predicted histological grading. Hysteroscopic-guided uterine sampling could be a useful tool to tailor treatment in patients with uterine

  17. Clinical evaluation of a mobile digital specimen radiography system for intraoperative specimen verification.

    Science.gov (United States)

    Wang, Yingbing; Ebuoma, Lilian; Saksena, Mansi; Liu, Bob; Specht, Michelle; Rafferty, Elizabeth

    2014-08-01

    Use of mobile digital specimen radiography systems expedites intraoperative verification of excised breast specimens. The purpose of this study was to evaluate the performance of a such a system for verifying targets. A retrospective review included 100 consecutive pairs of breast specimen radiographs. Specimens were imaged in the operating room with a mobile digital specimen radiography system and then with a conventional digital mammography system in the radiology department. Two expert reviewers independently scored each image for image quality on a 3-point scale and confidence in target visualization on a 5-point scale. A target was considered confidently verified only if both reviewers declared the target to be confidently detected. The 100 specimens contained a total of 174 targets, including 85 clips (49%), 53 calcifications (30%), 35 masses (20%), and one architectural distortion (1%). Although a significantly higher percentage of mobile digital specimen radiographs were considered poor quality by at least one reviewer (25%) compared with conventional digital mammograms (1%), 169 targets (97%), were confidently verified with mobile specimen radiography; 172 targets (98%) were verified with conventional digital mammography. Three faint masses were not confidently verified with mobile specimen radiography, and conventional digital mammography was needed for confirmation. One faint mass and one architectural distortion were not confidently verified with either method. Mobile digital specimen radiography allows high diagnostic confidence for verification of target excision in breast specimens across target types, despite lower image quality. Substituting this modality for conventional digital mammography can eliminate delays associated with specimen transport, potentially decreasing surgical duration and increasing operating room throughput.

  18. Value of CT-guided biopsy in malignant lymphoma; Wertigkeit der CT-gesteuerten Biopsie maligner Lymphome

    Energy Technology Data Exchange (ETDEWEB)

    Libicher, M.; Noeldge, G.; Radeleff, B.; Gholipur, F.; Richter, G.M. [Abteilung Radiodiagnostik, Universitaetsklinikum Heidelberg (Germany)

    2002-12-01

    Management of diagnosing malignant lymphomas has changed with development of CT-guided techniques and reliable biopsy tools.Pathologists can use representative tissue samples for sub classification in more than 90%.Evaluation of residual lymphoma or relapse can be nearly as effective. Therefore percutaneous biopsy can be considered as primary diagnostic tool in the absence of peripheral lymphadenopathy. CT-guided biopsies can be performed on an outpatient basis under conscious sedation considering contraindications as well as regional complications. Acceptance of percutaneous biopsy by the pathologist and oncologist is based on diagnostic effectiveness that is significantly improved if more than 3{dagger}solid tissue samples are taken. This article reviews the value of CT-guided biopsy in comparison to surgical procedures in patients with malignant lymphoma. Essential aspects that lead to a diagnostic percutaneous biopsy are discussed on grounds of the current literature. (orig.) [German] Mit der Entwicklung CT-gesteuerter Biopsieverfahren sowie zuverlaessiger Biopsiesysteme hat sich die Vorgehensweise bei der Diagnostik maligner Lymphome geaendert. Repraesentative Stanzzylinder mit hoher Praeparatequalitaet ermoeglichen dem Pathologen eine Subklassifikation der Lymphome in ueber 90%. Eine aehnlich hohe Treffsicherheit ist auch bei der Rezidivdiagnostik moeglich. Deshalb sind perkutane Biopsien bei fehlender peripherer Lymphadenopathie als primaere diagnostische Methode geeignet. Unter Beachtung der Kontraindikationen sowie der regional unterschiedlichen Komplikationsmoeglichkeiten koennen die meisten CT-gesteuerten Biopsien ambulant unter Analgosedierung durchgefuehrt werden. Die Akzeptanz perkutaner Biopsien durch Pathologen und Onkologen ist an die diagnostische Genauigkeit gekoppelt. Diese wird durch Gewinnung von mindestens 3 repraesentativen Biopsiezylindern aus den soliden Anteilen eines Lymphoms signifikant erhoeht. Die vorliegende Uebersichtsarbeit

  19. Rapidly decreased serum IgG to Campylobacter pylori following elimination of Campylobacter in histological chronic biopsy Campylobacter-positive gastritis.

    Science.gov (United States)

    van Bohemen, C G; Langenberg, M L; Rauws, E A; Oudbier, J; Weterings, E; Zanen, H C

    1989-01-15

    The anaerobic bacterium Campylobacter pylori (Cp) is thought to be associated with chronic gastritis. This paper presents clinical data underpinning this view. Five patients with histological chronic gastritis as determined by diagnostic endoscopy, which was associated with Cp as determined by positive biopsy cultures, all possessed statistically raised serum IgG ELISA titers to Cp during a longitudinal period of observation of 15 months. Treatment with the antibiotics amoxycillin (clamoxyl) or colloidal bismuth subcitrate (denol) eliminated Cp within one month. Associated with this, serum IgG ELISA titers were found to decrease sharply and rapidly. Tagamet and spiramycin had little effect. Although the data are preliminary, they support the assumed Cp involvement in chronic gastritis and suggest that specific serum IgG ELISA titers to Cp are useful parameters in monitoring disease status, exceeding bacteriological culture of biopsy specimens in speed and convenience.

  20. Multicenter study for the evaluation of a dedicated biopsy device for MR-guided vacuum biopsy of the breast

    International Nuclear Information System (INIS)

    Perlet, C.; Sittek, H.; Schneider, P.; Reiser, M.; Heinig, A.; Stets, C.; Heywang-Koebrunner, S.H.; Prat, X.; Lamarque, J.; Taourel, P.; Casselman, J.; Baath, L.; Anderson, I.

    2002-01-01

    The purpose of this multicenter study was to determine the accuracy and clinical value of a dedicated breast biopsy system which allows for MR-guided vacuum biopsy (VB) of contrast-enhancing lesions. In five European centers, MR-guided 11-gauge VB was performed on 341 lesions. In 7 cases VB was unsuccessful. This was immediately realized on postinterventional images or direct follow-up combined with histopathology-imaging correlation; thus, a false-negative diagnosis was avoided. Histology of 334 successful biopsies yielded 84 (25%) malignancies, 17 (5%) atypical ductal hyperplasias, and 233 (70%) benign entities. Verification of malignant or borderline lesions included reexcision of the biopsy cavity. Benign histologic biopsy results were verified by retrospective correlation with the pre- and postinterventional MRI and by subsequent follow-up. Our results indicate that MR-guided VB, in combination with the dedicated biopsy coil, offers the possibility to accurately diagnose even very small lesions that can only be visualized or localized by MRI. (orig.)

  1. Microscopic findings in EUS-guided fine needle (SharkCore) biopsies with type 1 and type 2 autoimmune pancreatitis

    DEFF Research Database (Denmark)

    Detlefsen, Sönke; Joergensen, Maiken Thyregod; Mortensen, Michael Bau

    2017-01-01

    The International Consensus Diagnostic Criteria (ICDC) for the diagnosis of autoimmune pancreatitis (AIP) include the histological criterion that is based on either pancreatic core needle biopsies (CNBs) or surgical specimens. However, CNBs are difficult to obtain by endoscopic ultrasound (EUS......). EUS fine-needle aspiration (EUS-FNA) cytology is usually not sufficient for the diagnosis of AIP, but may sometimes contain tissue microfragments. Another approach is EUS-guided histological fine-needle biopsy (EUS-FNB), using needles such as the SharkCore or ProCore needle. Published data regarding...... EUS-guided SharkCore FNB for the diagnosis of AIP are lacking. We aimed to describe our histological findings in one type 1 and two type 2 AIP patients who underwent EUS SharkCore FNB. The EUS-FNBs of two patients fulfilled the histological level 2 ICDC for type 1 AIP or type 2 AIP. The EUS-FNB of one...

  2. Optimal combinations for detection of prostate cancer: systematic sextant and laterally directed biopsies versus systematic sextant and color Doppler-targeted biopsies.

    Science.gov (United States)

    Kravchick, Sergey; Cytron, Shmuel; Peled, Ronit; London, Daniel; Sibi, Yosef; Ben-Dor, David

    2004-02-01

    To determine the accuracy of different combinations of biopsies in detecting prostate cancer. The standard sextant protocol for obtaining prostate biopsy underestimates the presence of prostate cancer. Conversely, an increased cancer detection rate has been obtained with additional laterally directed biopsies. The results of the studies dedicated to transrectal color Doppler (CD) sonography have shown that it might detect neoplastic lesions with no corresponding gray-scale abnormality. A total of 120 consecutive patients underwent sextant biopsy with additional biopsy cores taken from the lateral peripheral zone (four to six cores, depending on the prostate volume) and CD-guided biopsy. The sensitivity of laterally directed, CD-guided, and different combinations of biopsies was compared. Various patient, clinical, and pathologic factors were compared, and multivariate analysis was performed to assess the strongest predictor of cancer detection. Cancer was detected in 43 (35.8%) of 120 patients. The combination of sextant biopsy with laterally directed cores gained sensitivity to 56.6% compared with 67.4% obtained in the regimen that combined sextant and CD-guided biopsy. The CD regimen detected cancer in 11 additional patients. However, the differences in the detection rates of these combinations were not statistically significant (P = 0.797). The results of multivariate analysis showed that sextant biopsy and laterally directed cores were the strongest predictors of cancer detection (odds ratio 8.356 versus 49.282; 95% confidence interval 1.698 to 41.114 versus 10.508 to 231.130). The regimen that included sextant and CD-guided biopsy was the most sensitive. However, only standard sextant and laterally directed biopsies were statistically significant predictors of cancer detection on biopsy.

  3. Vortex-dislodged cells from bone marrow trephine biopsy yield satisfactory results for flow cytometric immunophenotyping.

    Science.gov (United States)

    Bommannan, K; Sachdeva, M U S; Gupta, M; Bose, P; Kumar, N; Sharma, P; Naseem, S; Ahluwalia, J; Das, R; Varma, N

    2016-10-01

    A good bone marrow (BM) sample is essential in evaluating many hematologic disorders. An unsuccessful BM aspiration (BMA) procedure precludes a successful flow cytometric immunophenotyping (FCI) in most hematologic malignancies. Apart from FCI, most ancillary diagnostic techniques in hematology are less informative. We describe the feasibility of FCI in vortex-dislodged cell preparation obtained from unfixed trephine biopsy (TB) specimens. In pancytopenic patients and dry tap cases, routine diagnostic BMA and TB samples were complemented by additional trephine biopsies. These supplementary cores were immediately transferred into sterile tubes filled with phosphate-buffered saline, vortexed, and centrifuged. The cell pellet obtained was used for flow cytometric immunophenotyping. Of 7955 BMAs performed in 42 months, 34 dry tap cases were eligible for the study. Vortexing rendered a cell pellet in 94% of the cases (32 of 34), and FCI rendered a rapid diagnosis in 100% of the cases (32 of 32) where cell pellets were available. We describe an efficient procedure which could be effectively utilized in resource-limited centers and reduce the frequency of repeat BMA procedures. © 2016 John Wiley & Sons Ltd.

  4. Freehand biopsy guided by electromagnetic needle tracking

    DEFF Research Database (Denmark)

    Ewertsen, C; Nielsen, Marie Kristina Rue; Nielsen, M Bachmann

    2011-01-01

    To evaluate the overall accuracy and time spent on biopsy guided by electromagnetic needle tracking in a phantom compared with the standard technique of US-guided biopsy with an attached steering device. Furthermore, to evaluate off-plane biopsy guided by needle tracking....

  5. CT diagnosis of the primary lung cancer and usefulness of biopsy under CT

    International Nuclear Information System (INIS)

    Fujisawa, Hidefumi; Kushihashi, Tamio

    2011-01-01

    CT especially plays an important role in imaging diagnosis of lung cancer (LC) which gives quite multiple CT findings and this paper describes details to be noted for CT findings of individual lung lesion and cancer according to 5 classes below, together with usefulness of CT-guided biopsy and positron emission tomography (PET) usage. Explained are as follows: Important points in histopathology and CT findings from adenomatous hyperplasia (AH) to atypical AH (pre-invasive lesion); Differential CT diagnosis of benignity or malignancy of pulmonary nodes and tumors; Typical CT findings of LC of peripheral type of invasive or exclusive proliferative type, and pulmonary hillar type; Atypical CT findings of LC/having atypical inner structure such as presenting atypical calcification and atypical cavity/having atypical morphology such as presenting pneumonia-like finding, exhibiting regular or linear edge, and existing at atypical region like extrapleural lumen /having atypical progression rate such as showing rapid or slow doubling time of the volume and shrinking tentatively during the progress/of juvenile LC/and generated from background lung diseases such as interstitial pneumonia, tuberculosis, pneumoconiosis like asbestosis, pneumosilicosis, and pulmonary emphysema and bulla; and Regional ground glass opacity. As well, authors mention about the usefulness of CT-guided needle biopsy of the pulmonary lesion which enables to take the nodal specimen as small as <10 mm. Most frequent complication of the biopsy is pneumothorax (10-50%). How to use PET for LC examination is also commented with its usability and limitation. (T.T.)

  6. Diagnosis of prostate cancer with needle biopsy: should all cases be biopsied before treatment?

    Science.gov (United States)

    Oranusi, C K; Ugezu, A I; Nwofor, Ame

    2012-01-01

    The triad of digital rectal examination (DRE), serum prostate specific antigen, and transrectal ultrasound-guided prostate biopsy is used in the detection of prostate cancer (PCa). It is recommended that all cases of PCa should be diagnosed with needle biopsy before treatment. The exclusion criteria for those that may not be suitable have not yet been defined. We reviewed all the patients diagnosed with PCa at the Nnamdi Azikiwe University Teaching Hospital Nnewi, Southeast, Nigeria, from January 2007 to December 2010. Relevant biodata and method of diagnosis of PCa before treatment were reviewed. A total of 133 patients had bilateral orchidectomy over the period. 120 (90.2%) had their diagnosis confirmed by needle biopsy before bilateral orchidectomy (category 1), while 13 (9.8%) had bilateral orchidectomy before diagnosis was confirmed. The method of diagnosis for category 1 patients was with lower urinary tract symptoms (LUTS), abnormal DRE findings, elevated prostate-specific antigen (PSA), and transrectal needle biopsy. For category 11 patients, diagnosis of PCa was suspected based on LUTS, abnormal DRE findings, and elevated PSA. Of this number, 11 (84.6%) had, in addition, sudden onset paraplegia at presentation, while 2 (15.4%) had severe uncontrolled hematuria at presentation. All the patients in both categories had needle biopsy confirmation of their disease. The sensitivity of PSA was 99.2%. Needle biopsy of the prostate is the preferred method for the diagnosis of PCa in most cases before treatment is undertaken. There are valid reasons why all PCas will not be diagnosed in this fashion. Elevated PSA when combined with an abnormal DRE finding increases the predictive value for cancer. In areas where pathologists are lacking, abnormal DRE and elevated PSA results can be a guide to proceed to treatment especially, where there is severe compromise of patients' quality of life due to symptoms of advanced PCa while awaiting confirmation.

  7. Post-treatment biopsy results following permanent transrectal ultrasound-guided interstitial brachytherapy in early stage prostate cancer

    International Nuclear Information System (INIS)

    Prestidge, Bradley R.; Blasko, John C.; Grimm, Peter D.; Hoak, David C.; Cavanagh, Bill; Ragde, Haakon

    1995-01-01

    minimum peripheral dose of 115 Gy with a median activity of 123 mCi. Sextant biopsies were performed under transrectal ultrasound guidance as well as any focal hypoechoic areas on ultrasound. All biopsy specimens were examined by a single, genitourinary pathologist and classified as either 'negative', 'indeterminate', or 'positive' depending on cellular, architectural, and immunohistochemical criteria. RESULTS: At the time of last biopsy, 161 (80%) have achieved negative pathology (median follow-up 30.8 months). 34 patients (17%) had indeterminate biopsies (median follow-up 21.0 months), and 6 (3%) were positive (median follow-up 30.0 months). Positive, indeterminate, and negative biopsy results by stage were respectively: 51 T1 - 1 (2%), 11 (22%), and 39 (76%); 125 T2a - 3 (2%), 23 (18%), and 99 (79%); 25 T2b/c - 2 (8%), 0, and 23 (92%). Excluding 6 patients with distant relapse proven on bone scan, median PSA values at the time of post-implant biopsy according to biopsy category were: negative 0.2 (range 0.1-7.4), indeterminate 0.5 (range 0.1-2.2), and positive 8.1 (range 2.6-26) (p < 0.005). Only 2 of the 186 patients with a PSA <4.0 at the time of biopsy were positive. All 6 of the positive, 26 indeterminate, and 111 negative biopsies were treated with I-125. Among the 58 Pd-103 patients, none have had positive biopsies, 8 have been indeterminate, and 50 negative. Among those 33 patients with a biopsy interpreted as 'indeterminate' who had serial biopsies, 28 subsequently converted to negative, 1 to positive, and 4 have remained indeterminate. The number of biopsies classified as indeterminate were time-dependent comprising 33% (48/144) of biopsies taken between 12 and 18 months, decreasing to 14.2% (15/106) at 18-30 months, and 5% (1/19) for biopsies taken 54 or more months post-implant. CONCLUSION: These data demonstrate an 80% biopsy confirmed local control rate following permanent prostate implant. In addition, a higher local control rate will likely be attained

  8. MRI-only lesions: application of diffusion-weighted imaging obviates unnecessary MR-guided breast biopsies

    Energy Technology Data Exchange (ETDEWEB)

    Spick, Claudio; Pinker-Domenig, Katja; Helbich, Thomas H.; Baltzer, Pascal A. [Medical University of Vienna (AKH), General Hospital Vienna, Department of Biomedical Imaging and Image-guided Therapy, Division of Molecular and Gender Imaging, Wien (Austria); Rudas, Margaretha [Medical University of Vienna (AKH), Clinical Institute of Pathology, Wien (Austria)

    2014-06-15

    To assess if the application of diffusion-weighted imaging (DWI) obviates unnecessary MR-guided biopsies in suspicious breast lesions visible only on contrast-enhanced MRI (CE-MRI). This institutional review board (IRB)-approved, retrospective, single-centre study included 101 patients (mean age, 49.5; SD 13.9 years) who underwent additional DWI at 1.5 T prior to MRI-guided biopsy of 104 lesions classified as suspicious for malignancy and visible on CE-MRI only. An experienced radiologist, blinded to histopathologic and follow-up results, measured apparent diffusion coefficient (ADC) values obtained from DWI. Diagnostic accuracy was investigated using receiver operating characteristics (ROC) analysis. Histopathology revealed 20 malignant and 84 benign lesions. Lesions were masses in 61 (15 malignant, 24.6 %) and non-masses in 43 cases (five malignant, 11.6 %). Mean ADC values were 1.53 ± 0.38 x 10{sup -3} mm{sup 2}/s in benign lesions and 1.06 ± 0.27 x 10{sup -3} mm{sup 2}/s in malignant lesions. ROC analysis revealed exclusively benign lesions if ADC values were greater than 1.58 x 10{sup -3} mm{sup 2}/s. As a consequence, 29 false-positive biopsies (34.5 %) could have been avoided without any false-negative findings. Both in mass and in non-mass lesions, rule-in and rule-out criteria were identified using flexible ADC thresholds based on ROC analysis. Additional application of DWI in breast lesions visible only on MRI can avoid false-positive, MR-guided biopsies. Thus, DWI should be an integral part of breast MRI protocols. (orig.)

  9. Direct measurement of catalase activity in living cells and tissue biopsies

    International Nuclear Information System (INIS)

    Scaglione, Christine N.; Xu, Qijin; Ramanujan, V. Krishnan

    2016-01-01

    Spatiotemporal regulation of enzyme-substrate interactions governs the decision-making steps in biological systems. Enzymes, being functional units of every living cell, contribute to the macromolecular stability of cell survival, proliferation and hence are vital windows to unraveling the biological complexity. Experimental measurements capturing this dynamics of enzyme-substrate interactions in real time add value to this understanding. Furthermore these measurements, upon validation in realistic biological specimens such as clinical biopsies – can further improve our capability in disease diagnostics and treatment monitoring. Towards this direction, we describe here a novel, high-sensitive measurement system for measuring diffusion-limited enzyme-substrate kinetics in real time. Using catalase (enzyme) and hydrogen peroxide (substrate) as the example pair, we demonstrate that this system is capable of direct measurement of catalase activity in vitro and the measured kinetics follows the classical Michaelis-Menten reaction kinetics. We further demonstrate the system performance by measuring catalase activity in living cells and in very small amounts of liver biopsies (down to 1 μg total protein). Catalase-specific enzyme activity is demonstrated by genetic and pharmacological tools. Finally we show the clinically-relevant diagnostic capability of our system by comparing the catalase activities in liver biopsies from young and old mouse (liver and serum) samples. We discuss the potential applicability of this system in clinical diagnostics as well as in intraoperative surgical settings. - Highlights: • A novel, direct measurement of Catalase enzyme activity via, oxygen sensing method. • Steady-stateprofiles of Catalase activity follow the Michaelis-Menten Kinetics. • Catalase-specific activity demonstrated using genetic and pharmacological tools. • Overcomes limitations of spectroscopic methods and indirect calorimetric approaches. • Clear

  10. Direct measurement of catalase activity in living cells and tissue biopsies

    Energy Technology Data Exchange (ETDEWEB)

    Scaglione, Christine N.; Xu, Qijin; Ramanujan, V. Krishnan, E-mail: Ramanujanv@csmc.edu

    2016-01-29

    Spatiotemporal regulation of enzyme-substrate interactions governs the decision-making steps in biological systems. Enzymes, being functional units of every living cell, contribute to the macromolecular stability of cell survival, proliferation and hence are vital windows to unraveling the biological complexity. Experimental measurements capturing this dynamics of enzyme-substrate interactions in real time add value to this understanding. Furthermore these measurements, upon validation in realistic biological specimens such as clinical biopsies – can further improve our capability in disease diagnostics and treatment monitoring. Towards this direction, we describe here a novel, high-sensitive measurement system for measuring diffusion-limited enzyme-substrate kinetics in real time. Using catalase (enzyme) and hydrogen peroxide (substrate) as the example pair, we demonstrate that this system is capable of direct measurement of catalase activity in vitro and the measured kinetics follows the classical Michaelis-Menten reaction kinetics. We further demonstrate the system performance by measuring catalase activity in living cells and in very small amounts of liver biopsies (down to 1 μg total protein). Catalase-specific enzyme activity is demonstrated by genetic and pharmacological tools. Finally we show the clinically-relevant diagnostic capability of our system by comparing the catalase activities in liver biopsies from young and old mouse (liver and serum) samples. We discuss the potential applicability of this system in clinical diagnostics as well as in intraoperative surgical settings. - Highlights: • A novel, direct measurement of Catalase enzyme activity via, oxygen sensing method. • Steady-stateprofiles of Catalase activity follow the Michaelis-Menten Kinetics. • Catalase-specific activity demonstrated using genetic and pharmacological tools. • Overcomes limitations of spectroscopic methods and indirect calorimetric approaches. • Clear

  11. Esophageal squamous cell carcinoma presenting as submucosal lesion with repeatedly negative endoscopic biopsies

    Directory of Open Access Journals (Sweden)

    Narendra S Choudhary

    2016-01-01

    Full Text Available A 74-year-old male presented with dysphagia for 2 months. Computed tomography revealed irregular wall thickening of the esophagus at T3 to T5 level. He underwent gastroscopy which revealed a submucosal bulge with normal mucosa at 25 cm from incisors. Repeated biopsies were taken, all were negative for malignancy. The patient underwent endoscopic ultrasound, and fine-needle aspiration was taken which was suggestive for squamous cell carcinoma.

  12. Can Single Positive Core Prostate Cancer at biopsy be Considered a Low-Risk Disease after Radical Prostatectomy?

    Directory of Open Access Journals (Sweden)

    Ricardo Kupka da Silva

    2013-12-01

    Full Text Available Purpose Single positive core in a prostate biopsy is usually associated with indolent prostate cancer (PCa and is one of the active surveillance (AS inclusion criteria. We investigated whether single positive core PCa at biopsy could define an archetype of low-risk disease. Materials and Methods A total of 1320 consecutive patients were enrolled. Among them, 249 patients with single positive core PCa were followed up, and the clinical and pathological parameters influencing prognosis were analyzed. Results Out of the 249 patients, 172 (69.0% had pathological findings ≥ pT2c and 87 (34.9% had an undergraded Gleason Score (GS based on the biopsy. Positive surgical margins (PSMs, extraprostatic extension (EPE and seminal vesicle invasion (SVI were found in 20.8%, 10.0% and 6.0% of patients, respectively. In a comparative analysis, we found that the PSA level, prostate weight and number of cores at biopsy are essential to correctly predict an indolent PCa. A total of 125 patients (67.3% with nonpalpable tumors became high-risk tumors (pT2c-T3. Analyzing only nonpalpable tumors with a GS of 6 at biopsy (156 patients, we noted that 106 (67.9% of cT1 progressed from cT1c to pT2c-pT3. Conclusions Single core PCa have clinically significant disease in the Radical Prostatectomy specimens, with considerable rates of overgrading for the GS, pT2c-pT3, PSMs, EPE and SVI. The treatment plan must be evaluated individually for patients with single core PCa and must take into account other prognostic factors when determining whether a patient should be managed with AS.

  13. Transrectal ultrasound and needle biopsy of the prostate

    Directory of Open Access Journals (Sweden)

    Tomaž Smrkolj

    2016-01-01

    Full Text Available In the last 25 years widespread use of prostatic specific antigen caused a stage migration of prostate cancer towards localized disease at diagnosis, which resulted in transrectal ultrasound biopsy to become standard in clinical practice. Transrectal ultrasound examination of the prostate is used to diagnose benign prostatic diseases, e.g. benign prostatic enlargement, prostatitis, prostatic and seminal vesicle cysts. It is also important in detection of obstructive causes of male infertility. Transrectal ultrasound examination is performed most often in needle biopsy for prostate cancer diagnosis. Besides guiding systematic tissue core biopsy, characteristic ultrasound changes enables target biopsies of suspect areas. The article describes indications, contraindications, antibiotic prophylaxis, various biopsy templates and complications of the needle biopsy. Experience with transrectal ultrasound guided biopsy at Department of urology at University medical center in Ljubljana is presented.

  14. Image-guided procedures in brain biopsy.

    Science.gov (United States)

    Fujita, K; Yanaka, K; Meguro, K; Narushima, K; Iguchi, M; Nakai, Y; Nose, T

    1999-07-01

    Image-guided procedures, such as computed tomography (CT)-guided stereotactic and ultrasound-guided methods, can assist neurosurgeons in localizing the relevant pathology. The characteristics of image-guided procedures are important for their appropriate use, especially in brain biopsy. This study reviewed the results of various image-guided brain biopsies to ascertain the advantages and disadvantages. Brain biopsies assisted by CT-guided stereotactic, ultrasound-guided, Neuronavigator-guided, and the combination of ultrasound and Neuronavigator-guided procedures were carried out in seven, eight, one, and three patients, respectively. Four patients underwent open biopsy without a guiding system. Twenty of 23 patients had a satisfactory diagnosis after the initial biopsy. Three patients failed to have a definitive diagnosis after the initial procedure, one due to insufficient volume sampling after CT-guided procedure, and two due to localization failure by ultrasound because the lesions were nonechogenic. All patients who underwent biopsy using the combination of ultrasound and Neuronavigator-guided methods had a satisfactory result. The CT-guided procedure provided an efficient method of approaching any intracranial target and was appropriate for the diagnosis of hypodense lesions, but tissue sampling was sometimes not sufficient to achieve a satisfactory diagnosis. The ultrasound-guided procedure was suitable for the investigation of hyperdense lesions, but was difficult to localize nonechogenic lesions. The combination of ultrasound and Neuronavigator methods improved the diagnostic accuracy even in nonechogenic lesions such as malignant lymphoma. Therefore, it is essential to choose the most appropriate guiding method for brain biopsy according to the radiological nature of the lesions.

  15. Unguided bronchoscopic biopsy: Does yield increase with operator experience

    Directory of Open Access Journals (Sweden)

    Tyagi Rahul

    2017-08-01

    Full Text Available Background Bronchoscopic Forceps biopsy (Endobronchial Biopsy (EBB and Trans Bronchial Lung Biopsy (TBLB are commonly performed for diagnosis in patients with endobronchial abnormalities or diffuse parenchymal involvement. As the operator gains experience his yield of various diagnostic bronchoscopic biopsies is expected to increase, however, no studies on the subject are available in literature. Aims To determine the effect of on- job experience on the yield of unguided bronchoscopic biopsies. Methods A total of 244 bronchoscopies were performed between Oct 2013 and Oct 2016. A retrospective analysis of all these bronchoscopies was undertaken. All patients who underwent biopsy were included in the study. Patients were divided into two groups with first group (Group A comprising of biopsies done between Oct 2013 to Apr 2015 and second group comprising biopsies done between May 2015 to Oct 2016 (Group B. The diagnostic yield in two groups was compared. Results Total 71 bronchoscopic biopsies were performed during Oct 2013 to Oct 2016. 36 patients were included in group A and 35 patients were included in group B. The groups were matched in demographic profile, clinical diagnosis, bronchoscopic findings and type of biopsy undertaken. The biopsy was diagnostic in 31 patient (43.6 per cent and nondiagnostic in 33 patients (46.4 per cent. There were 15 diagnostic biopsies in group A and 16 diagnostic biopsies in group B. The difference in the diagnostic biopsies between the two groups was not significant. Conclusion There was no significant impact of on job experience on diagnostic yield of biopsies. This may be due to adequate exposure during training leading to a diagnostic plateau being reached.

  16. Image-guided pleural biopsy: diagnostic yield and complications

    International Nuclear Information System (INIS)

    Benamore, R.E.; Scott, K.; Richards, C.J.; Entwisle, J.J.

    2006-01-01

    Background: Pleural biopsy and cytology are standard procedures for the investigation of pleural disease. Recent medical literature has suggested that image-guided pleural biopsy shows improved sensitivity for the diagnosis of pleural malignancy, when compared with the more commonly performed reverse bevel needle biopsy such as Abrams' needle. In our centre there has been an increasing trend towards performing image-guided pleural biopsies, and to our knowledge there is no large published series documenting the complication rate and diagnostic yield. Methods: The radiology and pathology databases were searched for all image-guided [computed tomography (CT) and ultrasound (US)] pleural biopsies from January 2001 to December 2004. All imaging and histology were reviewed, and final diagnostic information about patients was obtained from the respiratory multidisciplinary team database and patient notes. A record was made of complications following biopsy, presence of pleura in the biopsy, and adequacy of tissue for histological diagnosis. Results: A total of 82 patients underwent 85 image-guided pleural biopsies over a 4-year period. 80 cases were performed under CT and five under US guidance. The rate of new pneumothorax detected by chest radiography was 4.7%. No patient required a chest drain or blood transfusion to treat complications. In 10 (12%) cases, there was inadequate tissue to reach a confident histological diagnosis and in eight (9%) of these, no pleura was present. Assuming all suspicious and inadequate biopsies are treated as benign, which is the worst case scenario, image-guided pleural biopsy has a sensitivity and specificity of 76% and 100%, respectively, for the diagnosis of malignant disease. Conclusions: Image-guided pleural biopsy is a safe procedure with few associated complications and has a higher sensitivity than previously published series for reverse cutting needle biopsy in the diagnosis of malignant pleural disease

  17. Image-guided pleural biopsy: diagnostic yield and complications

    Energy Technology Data Exchange (ETDEWEB)

    Benamore, R.E. [Department of Radiology and Department of Histopathology, Glenfield Hospital, University Hospitals of Leicester NHS Trust, Leicester (United Kingdom)]. E-mail: rachelbenamore@doctors.org.uk; Scott, K. [Department of Radiology and Department of Histopathology, Glenfield Hospital, University Hospitals of Leicester NHS Trust, Leicester (United Kingdom); Richards, C.J. [Department of Radiology and Department of Histopathology, Glenfield Hospital, University Hospitals of Leicester NHS Trust, Leicester (United Kingdom); Entwisle, J.J. [Department of Radiology and Department of Histopathology, Glenfield Hospital, University Hospitals of Leicester NHS Trust, Leicester (United Kingdom)

    2006-08-15

    Background: Pleural biopsy and cytology are standard procedures for the investigation of pleural disease. Recent medical literature has suggested that image-guided pleural biopsy shows improved sensitivity for the diagnosis of pleural malignancy, when compared with the more commonly performed reverse bevel needle biopsy such as Abrams' needle. In our centre there has been an increasing trend towards performing image-guided pleural biopsies, and to our knowledge there is no large published series documenting the complication rate and diagnostic yield. Methods: The radiology and pathology databases were searched for all image-guided [computed tomography (CT) and ultrasound (US)] pleural biopsies from January 2001 to December 2004. All imaging and histology were reviewed, and final diagnostic information about patients was obtained from the respiratory multidisciplinary team database and patient notes. A record was made of complications following biopsy, presence of pleura in the biopsy, and adequacy of tissue for histological diagnosis. Results: A total of 82 patients underwent 85 image-guided pleural biopsies over a 4-year period. 80 cases were performed under CT and five under US guidance. The rate of new pneumothorax detected by chest radiography was 4.7%. No patient required a chest drain or blood transfusion to treat complications. In 10 (12%) cases, there was inadequate tissue to reach a confident histological diagnosis and in eight (9%) of these, no pleura was present. Assuming all suspicious and inadequate biopsies are treated as benign, which is the worst case scenario, image-guided pleural biopsy has a sensitivity and specificity of 76% and 100%, respectively, for the diagnosis of malignant disease. Conclusions: Image-guided pleural biopsy is a safe procedure with few associated complications and has a higher sensitivity than previously published series for reverse cutting needle biopsy in the diagnosis of malignant pleural disease.

  18. En bloc excision of nonpalpable breast lesions using the advanced breast biopsy instrumentation system: an alternative to needle guided surgery?

    International Nuclear Information System (INIS)

    Lifrange, E.; Colin, C.; Dondelinger, R.F.; Fridman, V.

    2001-01-01

    This study was prospectively conducted to evaluate the clinical potential of the advanced breast biopsy instrumentation (ABBI) system as an alternative to needle localization and open surgery in the management of nonpalpable breast lesions (NPBL). One hundred and eighty-six consecutive patients were referred for management of NPBL. Thirty-six underwent an ABBI procedure, offered as a first step before possible surgery for lesions which would in any case have required complete excision. The 18 patients with a malignant ABBI biopsy underwent re-excision of the biopsy site and axillary dissection was carried out in cases of infiltrating carcinoma. The other 150 patients underwent image-guided needle biopsy. Following these procedures, 60/150 (40 %) patients underwent needle-guided surgery. Finally, 96/186 (51 %) patients required complete excision. A total of 43 benign lesions and 53 carcinomas were confirmed. Thirty-six out of 96 (38 %) excisions were obtained with the ABBI system; 17/43 (40 %) benign lesions and 11/53 (21 %) carcinomas were completely removed with the ABBI system. Out of 9 malignant specimens with a pathological size less than 10 mm, 5/9 (55 %) had tumor-free margins and in 8/9 (89 %) no residual disease was found at re-excision. The preliminary results of this study suggest that, in selected cases, en bloc excision using the ABBI procedure could be an alternative to conventional surgery. (orig.)

  19. TU-CD-BRB-12: Radiogenomics of MRI-Guided Prostate Cancer Biopsy Habitats

    Energy Technology Data Exchange (ETDEWEB)

    Stoyanova, R; Lynne, C; Abraham, S; Patel, M; Jorda, M; Kryvenko, O; Ishkanian, A; Abramowitz, M; Pollack, A [University of Miami, Miami, FL (United States); Tachar, M; Erho, N; Buerki, C; Lam, L; Davicioni, E [GenomeDx Biosciences Inc., Vancouver, British Columbia (Canada)

    2015-06-15

    Purpose: Diagnostic prostate biopsies are subject to sampling bias. We hypothesize that quantitative imaging with multiparametric (MP)-MRI can more accurately direct targeted biopsies to index lesions associated with highest risk clinical and genomic features. Methods: Regionally distinct prostate habitats were delineated on MP-MRI (T2-weighted, perfusion and diffusion imaging). Directed biopsies were performed on 17 habitats from 6 patients using MRI-ultrasound fusion. Biopsy location was characterized with 52 radiographic features. Transcriptome-wide analysis of 1.4 million RNA probes was performed on RNA from each habitat. Genomics features with insignificant expression values (<0.25) and interquartile range <0.5 were filtered, leaving total of 212 genes. Correlation between imaging features, genes and a 22 feature genomic classifier (GC), developed as a prognostic assay for metastasis after radical prostatectomy was investigated. Results: High quality genomic data was derived from 17 (100%) biopsies. Using the 212 ‘unbiased’ genes, the samples clustered by patient origin in unsupervised analysis. When only prostate cancer related genomic features were used, hierarchical clustering revealed samples clustered by needle-biopsy Gleason score (GS). Similarly, principal component analysis of the imaging features, found the primary source of variance segregated the samples into high (≥7) and low (6) GS. Pearson’s correlation analysis of genes with significant expression showed two main patterns of gene expression clustering prostate peripheral and transitional zone MRI features. Two-way hierarchical clustering of GC with radiomics features resulted in the expected groupings of high and low expressed genes in this metastasis signature. Conclusions: MP-MRI-targeted diagnostic biopsies can potentially improve risk stratification by directing pathological and genomic analysis to clinically significant index lesions. As determinant lesions are more reliably

  20. Benign core biopsy of probably benign breast lesions 2 cm or larger: correlation with excisional biopsy and long-term follow-up

    OpenAIRE

    Jung, Hyun Kyung; Moon, Hee Jung; Kim, Min Jung; Kim, Eun-Kyung

    2014-01-01

    Purpose: To evaluate the accuracy of benign core biopsy of probably benign breast lesions (category 3) 2 cm or larger on the basis of excisional biopsy and long-term follow-up. Methods: We retrospectively reviewed 146 category 3 lesions in 146 patients 2 cm or larger which were diagnosed as benign by ultrasound (US)-guided core biopsy. Patients were initially diagnosed as benign at core needle biopsy and then followed up with excisional biopsy (surgical excision, n=91; US-guided vacuum assist...

  1. Racial Variation in the Outcome of Subsequent Prostate Biopsies in Men With an Initial Diagnosis of Atypical Small Acinar Proliferation.

    Science.gov (United States)

    Scott Libby, Robert; Kramer, Jordan J; Tue Nguyen, Hoang Minh; Feibus, Allison; Thomas, Raju; Silberstein, Jonathan L

    2017-12-01

    African American (AA) men are known to have more aggressive prostate cancer (PCa) compared with Caucasian American men. We sought to determine predictors of subsequent detection and risk stratification of PCa in a racially diverse group of men with atypical small acinar proliferation (ASAP) on initial prostate biopsy. A retrospective analysis was conducted on data from men with ASAP on initial prostate biopsy who subsequently received confirmatory biopsies between September 2000 and July 2015. Biopsies with more than 3 years between initial and confirmatory biopsies were excluded. Race, age, body mass index, transrectal ultrasound volume, serum prostate-specific antigen (PSA), PSA velocity, PSA density, and elapsed time between biopsies were assessed for predictive value in subsequent PCa diagnosis after an initial finding of ASAP. Of 106 men analyzed, 75 (71%) were AA and 31 (29%) were non-AA. Baseline variables revealed AA men had higher PSA levels, PSA velocity, and PSA density (all P level, and PSA density were significant predictors of PCa. AA men diagnosed with ASAP on initial prostate biopsy do not have increased risk of PCa on confirmatory biopsy compared with non-AA men. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. The role of stereotactic 11G vacuum biopsy for clarification of BI-RADS{sup TM} IV findings in mammography; Wertigkeit der stereotaktischen 11 G-Vakuumbiopsie zur Abklaerung von Befunden der Kategorie BI-RADS{sup TM} IV in der Mammographie

    Energy Technology Data Exchange (ETDEWEB)

    Diebold, T.; Jacobi, V.; Ballenberger, S.; Hochmuth, K.; Balzer, J.O.; Vogl, T.J. [Inst. fuer Diagnostische und Interventionelle Radiologie, Klinikum der J.W.G.-Univ. Frankfurt/Main (Germany); Krapfl, E.; Minckwitz, G. v.; Solbach, C.; Kaufmann, M. [Klinik fuer Gynaekologie und Geburtshilfe, Klinikum der J.W.G.-Univ. Frankfurt/Main (Germany); Fellbaum, M. [Senckenbergisches Inst. fuer Pathologie, Klinikum der J.W.G.-Univ. Frankfurt/Main (Germany)

    2003-04-01

    Purpose: To evaluate the potential of stereotactic vacuum breast biopsy in the histologic evaluation of suspicious mammographic findings (BI-RADS{sup TM} IV). Materials und Methods: In 221 patients with 227 probable mammographic lesions categorized as (BI-RADS{sup TM}-IV), stereotactic biopsies were performed with an 11-gauge vacuum-assisted biopsy device (Mammotome). The evaluation included the histology of the specimens obtained with the Mammotome or with surgery, the time for the biopsy, the amount of bleeding, number of rotations and procured specimens, the extent of the resection and the complications. Results: The biopsies were technically successful in 214 of the 227 probable mammographic lesions, with 176 lesions mostly resected and 34 lesions removed more than 50%. No representative tissue was obtained from 4 lesions. All biopsies were performed without any clinically relevant complications and terminated after adequate material was obtained (Oe 28 specimens, 2.58 rotations). The mean time needed for performing the biopsy was 40.2 minutes. The histologic findings were DCIS (42 lesions), ADH (7 lesions), LCIS (3 lesions), ID-Ca (14 lesions), IL-Ca (3 lesions), and IDL-Ca (1 lesion). In 28 of 42 lesions with the initial DCIS histology, the surgical histology was also DCIS (n=28) or no residual tumor (n=10). In 4 lesions with an initial DCIS-histology, the surgical histology was invasive ductal cancer (9.5%). The late follow-up examinations (up to 3 years) did not find any evidence of a false negative biopsy. Conclusion: Stereotactic vacuum breast biopsy ideally complements existing breast biopsy methods. The method is minimal invasive with a low rate of mostly minor complications. (orig.) [German] Ziel: Evaluierung der Wertigkeit der stereotaktischen Vakuumbiopsie zur Abklaerung von Befunden der Kategorie BI-RADS{sup TM} IV in der Mammographie. Material und Methode: Bei 221 Patientinnen mit 227 mammographischen Laesionen der BI-RADS{sup TM}-Kategorie IV

  3. Cone-beam computed tomography fusion and navigation for real-time positron emission tomography-guided biopsies and ablations: a feasibility study.

    Science.gov (United States)

    Abi-Jaoudeh, Nadine; Mielekamp, Peter; Noordhoek, Niels; Venkatesan, Aradhana M; Millo, Corina; Radaelli, Alessandro; Carelsen, Bart; Wood, Bradford J

    2012-06-01

    To describe a novel technique for multimodality positron emission tomography (PET) fusion-guided interventions that combines cone-beam computed tomography (CT) with PET/CT before the procedure. Subjects were selected among patients scheduled for a biopsy or ablation procedure. The lesions were not visible with conventional imaging methods or did not have uniform uptake on PET. Clinical success was defined by adequate histopathologic specimens for molecular profiling or diagnosis and by lack of enhancement on follow-up imaging for ablation procedures. Time to target (time elapsed between the completion of the initial cone-beam CT scan and first tissue sample or treatment), total procedure time (time from the moment the patient was on the table until the patient was off the table), and number of times the needle was repositioned were recorded. Seven patients underwent eight procedures (two ablations and six biopsies). Registration and procedures were completed successfully in all cases. Clinical success was achieved in all biopsy procedures and in one of the two ablation procedures. The needle was repositioned once in one biopsy procedure only. On average, the time to target was 38 minutes (range 13-54 min). Total procedure time was 95 minutes (range 51-240 min, which includes composite ablation). On average, fluoroscopy time was 2.5 minutes (range 1.3-6.2 min). An integrated cone-beam CT software platform can enable PET-guided biopsies and ablation procedures without the need for additional specialized hardware. Copyright © 2012 SIR. Published by Elsevier Inc. All rights reserved.

  4. Evaluation of specimen preparation techniques for micro-PIXE localisation of elements in hyperaccumulating plants

    International Nuclear Information System (INIS)

    Kachenko, Anthony G.; Siegele, Rainer; Bhatia, Naveen P.; Singh, Balwant; Ionescu, Mihail

    2008-01-01

    Hybanthus floribundus subsp. floribundus, a rare Australian Ni-hyperaccumulating shrub and Pityrogramma calomelanos var. austroamericana, an Australian naturalized As-hyperaccumulating fern are promising species for use in phytoremediation of contaminated sites. Micro-proton-induced X-ray emission (μ-PIXE) spectroscopy was used to map the elemental distribution of the accumulated metal(loid)s, Ca and K in leaf or pinnule tissues of the two plant species. Samples were prepared by two contrasting specimen preparation techniques: freeze-substitution in tetrahydrofuran (THF) and freeze-drying. The specimens were analysed to compare the suitability of each technique in preserving (i) the spatial elemental distribution and (ii) the tissue structure of the specimens. Further, the μ-PIXE results were compared with concentration of elements in the bulk tissue obtained by ICP-AES analysis. In H. floribundus subsp. floribundus, μ-PIXE analysis revealed Ni, Ca and K concentrations in freeze-dried leaf tissues were at par with bulk tissue concentrations. Elemental distribution maps illustrated that Ni was preferentially localised in the adaxial epidermal tissues (1% DW) and least concentration was found in spongy mesophyll tissues (0.53% DW). Conversely, elemental distribution maps of THF freeze-substituted tissues indicated significantly lower Ni, Ca and K concentrations than freeze-dried specimens and bulk tissue concentrations. Moreover, Ni concentrations were uniform across the whole specimen and no localisation was observed. In P. calomelanos var. austroamericana freeze-dried pinnule tissues, μ-PIXE revealed statistically similar As, Ca and K concentrations as compared to bulk tissue concentrations. Elemental distribution maps showed that As localisation was relatively uniform across the whole specimen. Once again, THF freeze-substituted tissues revealed a significant loss of As compared to freeze-dried specimens and the concentrations obtained by bulk tissue analysis

  5. The effect of residual stresses induced by prestraining on fatigue life of notched specimens

    Science.gov (United States)

    Sadeler, R.; Ozel, A.; Kaymaz, I.; Totik, Y.

    2005-06-01

    The effect of tensile prestraining-induced residual stress on the fatigue life of notched steel parts was investigated. The study was performed on AISI 4140 steel. Rotating bending fatigue tests were carried out on semicircular notched specimens with different notch radii in the as-quenched and tempered conditions. Metallography of the specimens was performed by means of light optical microscopy. The finite-element method was used to evaluate the residual stress distribution near the notch region. Fatigue tests revealed fatigue life improvement for notched specimens, which changes depending on the notch radii and applied stress. Scanning electron microscopy was used to examine the fracture surfaces of the specimens.

  6. Oral Biopsy: A Dental Gawk

    African Journals Online (AJOL)

    Sir,. Dermatologists are often confronted with neoplasms and diseases of the oral cavity. Although many may be reluctant to perform oral surgical procedures, a biopsy is often needed to establish a definitive diagnosis, and biopsy of the oral cavity is a safe and useful technique that can be easily employed by dermatologists.

  7. Postobstructive pulmonary edema after biopsy of a nasopharyngeal mass.

    Science.gov (United States)

    Mehta, Keyur Kamlesh; Ahmad, Sabina Qureshi; Shah, Vikas; Lee, Haesoon

    2015-01-01

    We describe a case of 17 year-old male with a nasopharyngeal rhabdomyosarcoma who developed postobstructive pulmonary edema (POPE) after removing the endotracheal tube following biopsy. He developed muffled voice, rhinorrhea, dysphagia, odynophagia, and difficulty breathing through nose and weight loss of 20 pounds in the preceding 2 months. A nasopharyngoscopy revealed a fleshy nasopharyngeal mass compressing the soft and hard palate. Head and neck MRI revealed a large mass in the nasopharynx extending into the bilateral choana and oropharynx. Biopsy of the mass was taken under general anesthesia with endotracheal intubation. Immediately after extubation he developed oxygen desaturation, which did not improve with bag mask ventilation with 100% of oxygen, but improved after a dose of succinylcholine. He was re-intubated and pink, frothy fluid was suctioned from the endotracheal tube. Chest radiograph (CXR) was suggestive of an acute pulmonary edema. He improved with mechanical ventilation and intravenous furosemide. His pulmonary edema resolved over the next 24 h. POPE is a rare but serious complication associated with upper airway obstruction. The pathophysiology of POPE involves hemodynamic changes occurring in the lung and the heart during forceful inspiration against a closed airway due to an acute or chronic airway obstruction. This case illustrates the importance of considering the development of POPE with general anesthesia, laryngospasm and removal of endotracheal tube to make prompt diagnosis and to initiate appropriate management.

  8. The biopsy of the boar testes using ultrasonographic examination

    Directory of Open Access Journals (Sweden)

    Laima Liepa

    2014-03-01

    Full Text Available The biopsy of live animal testes is an important clinical manipulation to control spermatogenesis and reproductive system pathologies. The aim was to develop a method of boar testes biopsy using a biopsy gun with ultrasound guidance and to investigate the influence of this procedure on the boar testes parenchyma and quality of ejaculate. The biopsy was carried out in six 8-month-old boars. Fourteen days prior to and 21 days after biopsy, the quality of ejaculate was examined (weight of ejaculate; concentration and motility of spermatozoa with a seven-day intervals. Ultrasound images of the testes parenchyma were recorded three times: directly before and 15 minutes after the biopsy, then 21 days after the procedure. The testes biopsies of generally anesthetized boars were performed with the biopsy gun for needle biopsy with a 12cm long, disposable 16-gauge needle 1.8mm in diameter (Vitesse through 1cm skin incision in the depth of 1.2-1.6cm of parenchyma. Fifteen minutes after the biopsy, macroscopic injures of the parenchyma of all the boar testes were not detected in the ultrasound image. Twenty one days after biopsy, the hyperechogenic line 0.1-0.2cm in diameter was seen in the testes parenchyma of six boars in the depth of 1.2-1.6cm. The biopsy of boar testes did not influence the quality of boars ejaculate. The ultrasonographic examination of boar testicles before the biopsy reduced possibilities to traumatize large blood vessels of the testes. A perfect boar testicular biopsy was easy to perform using ultrasonographic examination in the pigsty conditions.

  9. Full-thickness rectal biopsy in children suspicious for Hirschsprung's disease is safe and yields a low number of insufficient biopsies

    DEFF Research Database (Denmark)

    Bjørn, Niels; Rasmussen, Lars; Qvist, Niels

    2018-01-01

    INTRODUCTION: The diagnosis of Hirschsprung's disease (HD) relies on the histological demonstration of aganglionosis in the bowel wall. Biopsies may be obtained by rectal suction biopsy (RSB) or by transanal full-thickness excision biopsy (FTB). The objective of the present study was to evaluate...... the frequency of complications and inconclusive biopsies after FTB in children referred with suspicion of HD. The secondary objective was to calculate the frequency of proven aganglionosis. METHODS: A retrospective chart review was performed of all patients under the age of 16years who underwent transanal FTB...... during the time period of 2008-2014. RESULTS: A total of 555 patients were included in the review. Inconclusive biopsies were found at the primary biopsy in 35 patients (5.9%). Aganglionosis was found in 12% of the cases. The complication rate was 6.6% (39 patients), 85% of which were classified...

  10. Clinical relevance of DNA microarray analyses using archival formalin-fixed paraffin-embedded breast cancer specimens

    International Nuclear Information System (INIS)

    Sadi, Al Muktafi; Wang, Dong-Yu; Youngson, Bruce J; Miller, Naomi; Boerner, Scott; Done, Susan J; Leong, Wey L

    2011-01-01

    The ability of gene profiling to predict treatment response and prognosis in breast cancers has been demonstrated in many studies using DNA microarray analyses on RNA from fresh frozen tumor specimens. In certain clinical and research situations, performing such analyses on archival formalin fixed paraffin-embedded (FFPE) surgical specimens would be advantageous as large libraries of such specimens with long-term follow-up data are widely available. However, FFPE tissue processing can cause fragmentation and chemical modifications of the RNA. A number of recent technical advances have been reported to overcome these issues. Our current study evaluates whether or not the technology is ready for clinical applications. A modified RNA extraction method and a recent DNA microarray technique, cDNA-mediated annealing, selection, extension and ligation (DASL, Illumina Inc) were evaluated. The gene profiles generated from FFPE specimens were compared to those obtained from paired fresh fine needle aspiration biopsies (FNAB) of 25 breast cancers of different clinical subtypes (based on ER and Her2/neu status). Selected RNA levels were validated using RT-qPCR, and two public databases were used to demonstrate the prognostic significance of the gene profiles generated from FFPE specimens. Compared to FNAB, RNA isolated from FFPE samples was relatively more degraded, nonetheless, over 80% of the RNA samples were deemed suitable for subsequent DASL assay. Despite a higher noise level, a set of genes from FFPE specimens correlated very well with the gene profiles obtained from FNAB, and could differentiate breast cancer subtypes. Expression levels of these genes were validated using RT-qPCR. Finally, for the first time we correlated gene expression profiles from FFPE samples to survival using two independent microarray databases. Specifically, over-expression of ANLN and KIF2C, and under-expression of MAPT strongly correlated with poor outcomes in breast cancer patients. We

  11. The need for using fluoroscopic guidance to obtain gastric biopsies when in search of Helicobacter pylori with a nonendoscopic method

    International Nuclear Information System (INIS)

    Bender, Greg N.; Mullins, Daniel J.; Makuch, Richard S.

    1999-01-01

    Purpose: Nonendoscopic, fluoroscopic biopsy of the gastric mucosa, following barium examination of the stomach, has gained attention with its ease of performance and cost savings potential over endoscopy. Endoscopic research concerning the efficacy of biopsy sites has revealed an increased sensitivity of antral biopsies over greater curvature biopsies for the detection of Helicobacter pylori. Fluoroscopically guided biopsies of the gastric mucosal are studied to determine whether such a difference between site sensitivity held true. If not, blind biopsy through a nasogastric tube, which traditionally samples only the greater curvature, might prove an even less expensive alternative. Materials and methods: Seventy-two patients underwent nonendoscopic, fluoroscopically guided, mucosal biopsy of both the gastric antrum and the greater curvature of the stomach. Pathologic reports from both sites, using each patient as their own control, are compared to assess site sensitivity in the diagnosis of H. pylori gastritis. Results: The sensitivity for the detection of H. pylori gastritis by antral biopsy is 89% whereas the sensitivity of greater curvature biopsy is 62%. The difference is considered clinically significant at P≤0.05. Conclusions: This study confirms the need for antral biopsies when desiring a nonendoscopic approach to gastric mucosal sampling, in order to obtain a reasonable yield of data in dyspeptic patients with H. pylori gastritis. Blind techniques cannot reliably reach the antrum. Fluoroscopy can, and remains a less expensive alternative to endoscopy

  12. The need for using fluoroscopic guidance to obtain gastric biopsies when in search of Helicobacter pylori with a nonendoscopic method

    Energy Technology Data Exchange (ETDEWEB)

    Bender, Greg N.; Mullins, Daniel J.; Makuch, Richard S

    1999-12-01

    Purpose: Nonendoscopic, fluoroscopic biopsy of the gastric mucosa, following barium examination of the stomach, has gained attention with its ease of performance and cost savings potential over endoscopy. Endoscopic research concerning the efficacy of biopsy sites has revealed an increased sensitivity of antral biopsies over greater curvature biopsies for the detection of Helicobacter pylori. Fluoroscopically guided biopsies of the gastric mucosal are studied to determine whether such a difference between site sensitivity held true. If not, blind biopsy through a nasogastric tube, which traditionally samples only the greater curvature, might prove an even less expensive alternative. Materials and methods: Seventy-two patients underwent nonendoscopic, fluoroscopically guided, mucosal biopsy of both the gastric antrum and the greater curvature of the stomach. Pathologic reports from both sites, using each patient as their own control, are compared to assess site sensitivity in the diagnosis of H. pylori gastritis. Results: The sensitivity for the detection of H. pylori gastritis by antral biopsy is 89% whereas the sensitivity of greater curvature biopsy is 62%. The difference is considered clinically significant at P{<=}0.05. Conclusions: This study confirms the need for antral biopsies when desiring a nonendoscopic approach to gastric mucosal sampling, in order to obtain a reasonable yield of data in dyspeptic patients with H. pylori gastritis. Blind techniques cannot reliably reach the antrum. Fluoroscopy can, and remains a less expensive alternative to endoscopy.

  13. Comparison of plain potassium hydroxide mounts, fungal cultures and nail plate biopsies in the diagnosis of onychomycosis.

    Science.gov (United States)

    Malik, Naveed Akhter; Nasiruddin; Dar, Nasser Rasheed; Khan, Ashfaq Ahmed

    2006-10-01

    To compare the relative sensitivity of direct microscopy, fungal culture and nail plate biopsy in the diagnosis of onychomycosis. Cross-sectional study. The Skin Department, Military Hospital, Rawalpindi from February 1998 to February 1999. A total of 50 patients who were suffering from different clinical variants of onychomycosis, irrespective of their age, gender, with or without simultaneous presence of systemic diseases, were subjected to laboratory investigations including direct microscopy with 20% potassium hydroxide (KOH) for fungal hyphae, fungal cultures and nail plate biopsies. These patients were later categorized into two groups based upon the results of nail plate biopsies. Of 50 patients, 15 (30%) were positive for fungal elements in direct microscopy, 8 (16%) were positive for fungal culture and 16 (32%) revealed positive results in nail plate biopsies. Amongst nail plate biopsy positive cases, 10 (63%) were positive for direct microscopy and 6 (37.5%) were positive for fungal cultures. In biopsy negative cases, positive results for direct microscopy were seen in 5 (14.7%) patients and positive fungal culture was found in 2 (5.88%) patients. The clinical impression of onychomycosis is not true in all the cases. Nail scraping for direct microscopy with 20% KOH should be the first line screening test for all patients which should then be supplemented with fungal culture and/ or nail plate biopsy.

  14. Preoperative core needle biopsy is accurate in determining molecular subtypes in invasive breast cancer

    International Nuclear Information System (INIS)

    Chen, Xiaosong; Yuan, Ying; Fei, Xiaochun; Jin, Xiaolong; Shen, Kunwei; Sun, Long; Mao, Yan; Zhu, Siji; Wu, Jiayi; Huang, Ou; Li, Yafen; Chen, Weiguo; Wang, Jianhua

    2013-01-01

    Estrogen receptor (ER), progesterone receptor (PgR), HER2, and Ki67 have been increasingly evaluated by core needle biopsy (CNB) and are recommended for classifying breast cancer into molecular subtypes. However, the concordance rate between CNB and open excision biopsy (OEB) has not been well documented. Patients with paired CNB and OEB samples from Oct. 2009 to Feb. 2012 in Ruijin Hospital were included. ER, PgR, HER2, and Ki67 were determined by immunohistochemistry (IHC). Patients with HER2 IHC 2+ were further examined by FISH. Cutoff value for Ki67 high expression was 14%. Molecular subtypes were constructed as follows: Luminal A, Luminal B, Triple Negative, and HER2 positive. There were 298 invasive breast cancer patients analyzed. Concordance rates for ER, PgR, and HER2 were 93.6%, 85.9%, and 96.3%, respectively. Ki67 expression was slightly higher in OEB than in CNB samples (29.3% vs. 26.8%, P = 0.046). Good agreement (κ = 0.658) was demonstrated in evaluating molecular subtypes between CNB and OEB, with a concordance rate of 77.2%. We also used a different Ki67 cutoff value (20%) for determining Luminal A and B subtypes in HR (hormone receptor) +/HER2- diseases and the overall concordance rate was 79.2%. However, using a cut-point of Ki67 either 14% or 20% for both specimens, there will be about 14% of HR+/HER2- specimens that are called Luminal A on CNB and Luminal B on OEB. CNB was accurate in determining ER, PgR, and HER2 status as well as non-Luminal molecular subtypes in invasive breast cancer. Ki67 should be retested on OEB samples in HR+/HER2- patients to accurately distinguish Luminal A from B tumors

  15. Follow-up Sonography after Sonoguided Renal Biopsy

    International Nuclear Information System (INIS)

    Kim, Hyung Soo; Park, Cheol Min; Cha, In Ho

    1996-01-01

    To assess ultrasonographic findings and clinical significance after renal biopsy. 174 cases of post-biopsy sonography were studied retrospectively. We classified post-biopsy hematoma on the basis of their size as small (thickness less than 1 cm, length less than 3cm), medium (thickness less than 1cm, length greater than 3 cm), large (thickness greater than 1 cm, length greater than 3 cm). We also compared bleeding parameters (prothrombin time, partial thromboplastin time) and renal function in both cases which had hematoma or not. Total 33 hematomas were found (19%). Small hematoma was observed in 14 cases, medium hematoma in 16 cases, large hematoma in 3 cases. Severe complications requiring prompt therapy occurred in 1 case(0.6%). In 6 cases hematocrit fell by more than 4%, all of these hematomas were observed on US. Severe complications after sonoguided renal biopsy were rare. There was poor correlation between prebiopsybleeding parameter, renal function and post-biopsy hematomas. And sonography is considered as adequate method for follow up of post-biopsy hematoma

  16. Prostatic biopsy after irradiation therapy for prostatic cancer

    International Nuclear Information System (INIS)

    Scardino, P.T.; Wheeler, T.M.

    1985-01-01

    To determine the prognostic significance of a routine needle biopsy of the prostate performed six to thirty-six months after the completion of definitive radiotherapy, biopsy results were analyzed in 146 patients who had no evidence of disease at the time of biopsy and who received no other therapy before proved recurrence of the tumor. Patients were followed up a mean of 3.9 years after radioactive gold seed implantation and external beam irradiation. The total dose was 8,000 rad. Among 146 patients, 56 (38%) had one or more positive biopsy results within this time interval. The positive biopsy rate correlated with the clinical stage ranging from 17 per cent in Stage B1N to 59 per cent in Stage C1. The risk of developing local recurrence or distant metastases at any given time after irradiation therapy was markedly greater in those patients with a positive biopsy result (p less than 0.0005). Prostatic biopsy is an accurate means of measuring the success of radiotherapy. A positive postirradiation biopsy result carries grave prognostic implications for the patient and indicates that the treatment has failed

  17. Sentinel node biopsy in penile cancer

    DEFF Research Database (Denmark)

    Jakobsen, J. K.; Krarup, K. P.; Sommer, P.

    2015-01-01

    INTRODUCTION & OBJECTIVES: Nodal involvement is a strong prognosticator in penile cancer and lymph node staging is crucial. Sentinel node biopsy (SNB) has proven a useful staging tool with few complications, but evidence rely mostly on single institution publications with a short follow-up. In th......INTRODUCTION & OBJECTIVES: Nodal involvement is a strong prognosticator in penile cancer and lymph node staging is crucial. Sentinel node biopsy (SNB) has proven a useful staging tool with few complications, but evidence rely mostly on single institution publications with a short follow...... died from complications. CONCLUSIONS: To our knowledge, this is the first complete national study on sentinel node biopsy. Penile cancer sentinel node biopsy with a close follow-up is a reliable lymph node staging and has few complications in a national multicentre setting. Inguinal lymph node...

  18. Computed tomography guidance for skeletal biopsy

    International Nuclear Information System (INIS)

    Frager, D.H.; Goldman, M.J.; Elkin, C.M.; Cynamon, J.; Leeds, N.E.; Seimon, L.P.; Habermann, E.T.; Schreiber, K.; Freeman, L.M.

    1987-01-01

    Computed tomographic (CT) guided biopsy and abscess drainage of multiple organ systems have been well described. Reports of spinal and skeletal applications have been less common. This study describes the use of CT guidance in the biopsy of various skeletal lesions in 46 patients. Forty-one patients had skinny needle aspirations (18 or 22 gauge) and 23 patients had trephine core biopsies. Sites of the lesions included: thoracic spine - 15 patients, lumbosacral spine - 17 patients, bony pelvis - 6 patients, rib - 2 patients, and long bones - 6 patients. Fast scanners capable of rapid image reconstruction have overcome many constraints. With CT guidance, the physician who performs the procedure receives virtually no ionizing radiation. The exact location of the needle tip is accurately visualized in relation to the lesion being biopsied and to the vital organs. (orig.)

  19. Transbronchial biopsies safely diagnose amyloid lung disease

    Science.gov (United States)

    Govender, Praveen; Keyes, Colleen M.; Hankinson, Elizabeth A.; O’Hara, Carl J.; Sanchorawala, Vaishali; Berk, John L.

    2018-01-01

    Background Autopsy identifies lung involvement in 58–92% of patients with the most prevalent forms of systemic amyloidoses. In the absence of lung biopsies, amyloid lung disease often goes unrecognized. Report of a death following transbronchial biopsies in a patient with systemic amyloidosis cautioned against the procedure in this patient cohort. We reviewed our experience with transbronchial biopsies in patients with amyloidosis to determine the safety and utility of bronchoscopic lung biopsies. Methods We identified patients referred to the Amyloidosis Center at Boston Medical Center with lung amyloidosis diagnosed by transbronchial lung biopsies (TBBX). Amyloid typing was determined by immunohistochemistry or mass spectrometry. Standard end organ assessments, including pulmonary function test (PFT) and chest tomography (CT) imaging, and extra-thoracic biopsies established the extent of disease. Results Twenty-five (21.7%) of 115 patients with lung amyloidosis were diagnosed by TBBX. PFT classified 33.3% with restrictive physiology, 28.6% with obstructive disease, and 9.5% mixed physiology; 9.5% exhibited isolated diffusion defects while 19% had normal pulmonary testing. Two view chest or CT imaging identified focal opacities in 52% of cases and diffuse interstitial disease in 48%. Amyloid type and disease extent included 68% systemic AL disease, 16% localized (lung limited) AL disease, 12% ATTR disease, and 4% AA amyloidosis. Fluoroscopy was not used during biopsy. No procedure complications were reported. Conclusions Our case series of 25 patients supports the use of bronchoscopic transbronchial biopsies for diagnosis of parenchymal lung amyloidosis. Normal PFTs do not rule out the histologic presence of amyloid lung disease. PMID:28393574

  20. Post-ion beam induced degradation of copper layers in transmission electron microscopy specimens

    Science.gov (United States)

    Seidel, F.; Richard, O.; Bender, H.; Vandervorst, W.

    2015-11-01

    Copper containing transmission electron microscopy (TEM) specimens frequently show corrosion after focused ion beam (FIB) preparation. This paper reveals that the corrosion product is a Cu-S phase growing over the specimen surface. The layer is identified by energy-dispersive x-ray spectroscopy, and lattice spacing indexing of power spectra patterns. The corrosion process is further studied by TEM on cone-shaped specimens, which are intentionally stored after FIB preparation with S flakes for short time. Furthermore, a protective method against corrosion is developed by varying the time in the FIB vacuum and the duration of a subsequent plasma cleaning.