WorldWideScience

Sample records for biopsy specimens obtained

  1. Breast cancer: determining the genetic profile from ultrasound-guided percutaneous biopsy specimens obtained during the diagnostic workups.

    Science.gov (United States)

    López Ruiz, J A; Zabalza Estévez, I; Mieza Arana, J A

    2016-01-01

    To evaluate the possibility of determining the genetic profile of primary malignant tumors of the breast from specimens obtained by ultrasound-guided percutaneous biopsies during the diagnostic imaging workup. This is a retrospective study in 13 consecutive patients diagnosed with invasive breast cancer by B-mode ultrasound-guided 12 G core needle biopsy. After clinical indication, the pathologist decided whether the paraffin block specimens seemed suitable (on the basis of tumor size, validity of the sample, and percentage of tumor cells) before sending them for genetic analysis with the MammaPrint® platform. The size of the tumors on ultrasound ranged from 0.6cm to 5cm. In 11 patients the preserved specimen was considered valid and suitable for use in determining the genetic profile. In 1 patient (with a 1cm tumor) the pathologist decided that it was necessary to repeat the core biopsy to obtain additional samples. In 1 patient (with a 5cm tumor) the specimen was not considered valid by the genetic laboratory. The percentage of tumor cells in the samples ranged from 60% to 70%. In 11/13 cases (84.62%) it was possible to do the genetic analysis on the previously diagnosed samples. In most cases, regardless of tumor size, it is possible to obtain the genetic profile from tissue specimens obtained with ultrasound-guided 12 G core biopsy preserved in paraffin blocks. Copyright © 2015 SERAM. Published by Elsevier España, S.L.U. All rights reserved.

  2. High concordance of findings obtained from transgluteal magnetic resonance imaging - and transrectal ultrasonography-guided biopsy as compared with prostatectomy specimens.

    Science.gov (United States)

    Steurer, Stefan; Rico, Sebastian Dwertmann; Simon, Ronald; Minner, Sarah; Tsourlakis, Maria Christina; Krech, Till; Koop, Christina; Graefen, Markus; Heinzer, Hans; Adam, Meike; Huland, Hartwig; Schlomm, Thorsten; Sauter, Guido; Lumiani, Agron

    2017-09-01

    To determine the utility of our transgluteal magnetic resonance imaging (MRI)-guided prostate biopsy approach. A total of 960 biopsy series, taken within the period of 1 year, were evaluated, including 301 MRI-guided and 659 transrectal ultrasonography (TRUS)-guided biopsies. The positivity rate and proportion of high grade cancers were significantly higher in MRI-guided than in TRUS-guided biopsies. Of 301 MRI-guided biopsies, 65.4% contained cancer while 57.2% of 659 TRUS biopsies contained cancer (P = 0.016). Gleason grade 3 + 3 = 6 disease was observed in 16.8% of 197 MRI-guided and in 36.1% of 377 TRUS-guided biopsies (P guided biopsies. In all cancers, the mean cancer surface area was 64.8 ± 51.6 mm 2 in MRI-guided biopsies as compared with 23.0 ± 31.4 mm 2 in non-MRI-guided biopsies (P guided biopsy was highest in Gleason grade 3 + 3 = 6 cancers (20.9 ± 27.9 vs 5.1 ± 10.2 mm 2 ; P guided and in 170 patients with non-MRI-guided biopsies. This comparison showed a very high but almost identical concordance of TRUS- and MRI-guided biopsies with the prostatectomy specimen findings. With both approaches, undetected high-risk cancers were present in ~10% of patients with low-risk biopsy results. A significant difference was observed, however, in the proportion of patients who had clinically insignificant cancers and who underwent surgery. The proportion of patients with Gleason grade 3 + 3 = 6 carcinoma in their prostatectomy specimen was 11.2% in the post-TRUS biopsy cohort, but only 2.5% in the post-MRI biopsy cohort (P = 0.021). MRI-guided transgluteal prostate biopsy has a high detection rate for high-risk carcinomas, while the risk of detecting clinically insignificant carcinomas appears to be reduced. This may by itself lead to a reduction of unnecessary prostatectomies. Overtreatment may be further avoided by better applicability of molecular testing to MRI-guided biopsies because of the excessive amount of tissue available for analysis, especially in

  3. SU-F-J-07: Evaluating the Adequacy of Biopsy Specimens for Genetic Signature Assessment by Measuring the Metabolic Activity in Specimens Obtained Under 18F-FDG PET/CT Guidance

    Energy Technology Data Exchange (ETDEWEB)

    Fanchon, L; Russell, J; Dogan, S; Carlin, S; Pinker-Domenig, K; Yorke, E; Schmidtlein, C. Ross; Fujisawa, S; Manova-Todorova, K; Zanzonico, P; Deasy, J O; Humm, J L; Solomon, S; Kirov, A S [Memorial Sloan Kettering Cancer Center, New York, NY (United States)

    2016-06-15

    Purpose: Genetic profiling of biopsied tissue is the basis for personalized cancer therapy. However biopsied materials may not contain sufficient amounts of DNA needed for analysis. We propose a method to determine the adequacy of specimens for performing genetic profiling by quantifying metabolic activity. Methods: We measured the response of two radiation detectors to the activity contained in the minimum amount of tumor cells needed for genetic profiling in biopsy specimens obtained under 2-deoxy-2-({sup 18}F)fluoro-D-glucose ({sup 18}F-FDG) PET/CT guidance. The expected tumor cell concentration in biopsy specimens was evaluated from the amount of DNA needed (∼100 µg) and the number of pathology sections typically used for the analysis. The average {sup 18}F-FDG uptake per cell was measured by incubating KPC-4662 pancreatic tumor cells and HT-29 colorectal adenocarcinoma tumor cells in {sup 18}F-FDG containing solution (activity concentrations between 0.0122 and 1.51 MBq/mL and glucose concentrations of 3.1 and 1 g/L) for 1 to 1.75 hours and then measuring the activity of a known number of cells. Measurements of surrogate specimens obtained using 18G needle biopsies of gels containing these cells in expected concentrations (∼10{sup 4} µL{sup −1}) were performed using an autoradiography CCD based device (up to 20 min exposure) and a scintillation well counter (∼1 min measurements) about 3 and 5 hours after the end of incubation respectively. Results: At start of autoradiography there were between 0.16 and 1.5 {sup 18}F-FDG molecules/cell and between 1.14 and 5.43×10{sup 7} {sup 18}F-FDG molecules/mL. For the scintillation well counter, sample to minimum-detectable-count rate ratios were greater than 7 and the counting error was less than 25% for ≤80 s measurement times. Images of the samples were identifiable on the autoradiograph for ∼10 min and longer exposure times. Conclusion: Scintillation well counter measurements and CCD based

  4. SU-F-J-07: Evaluating the Adequacy of Biopsy Specimens for Genetic Signature Assessment by Measuring the Metabolic Activity in Specimens Obtained Under 18F-FDG PET/CT Guidance

    International Nuclear Information System (INIS)

    Fanchon, L; Russell, J; Dogan, S; Carlin, S; Pinker-Domenig, K; Yorke, E; Schmidtlein, C. Ross; Fujisawa, S; Manova-Todorova, K; Zanzonico, P; Deasy, J O; Humm, J L; Solomon, S; Kirov, A S

    2016-01-01

    Purpose: Genetic profiling of biopsied tissue is the basis for personalized cancer therapy. However biopsied materials may not contain sufficient amounts of DNA needed for analysis. We propose a method to determine the adequacy of specimens for performing genetic profiling by quantifying metabolic activity. Methods: We measured the response of two radiation detectors to the activity contained in the minimum amount of tumor cells needed for genetic profiling in biopsy specimens obtained under 2-deoxy-2-( 18 F)fluoro-D-glucose ( 18 F-FDG) PET/CT guidance. The expected tumor cell concentration in biopsy specimens was evaluated from the amount of DNA needed (∼100 µg) and the number of pathology sections typically used for the analysis. The average 18 F-FDG uptake per cell was measured by incubating KPC-4662 pancreatic tumor cells and HT-29 colorectal adenocarcinoma tumor cells in 18 F-FDG containing solution (activity concentrations between 0.0122 and 1.51 MBq/mL and glucose concentrations of 3.1 and 1 g/L) for 1 to 1.75 hours and then measuring the activity of a known number of cells. Measurements of surrogate specimens obtained using 18G needle biopsies of gels containing these cells in expected concentrations (∼10 4 µL −1 ) were performed using an autoradiography CCD based device (up to 20 min exposure) and a scintillation well counter (∼1 min measurements) about 3 and 5 hours after the end of incubation respectively. Results: At start of autoradiography there were between 0.16 and 1.5 18 F-FDG molecules/cell and between 1.14 and 5.43×10 7 18 F-FDG molecules/mL. For the scintillation well counter, sample to minimum-detectable-count rate ratios were greater than 7 and the counting error was less than 25% for ≤80 s measurement times. Images of the samples were identifiable on the autoradiograph for ∼10 min and longer exposure times. Conclusion: Scintillation well counter measurements and CCD based autoradiography have adequate sensitivity to detect the

  5. Technical Note: Scintillation well counters and particle counting digital autoradiography devices can be used to detect activities associated with genomic profiling adequacy of biopsy specimens obtained after a low activity18F-FDG injection.

    Science.gov (United States)

    Kirov, Assen S; Fanchon, Louise M; Seiter, Daniel; Czmielewski, Christian; Russell, James; Dogan, Snjezana; Carlin, Sean; Pinker-Domenig, Katja; Yorke, Ellen; Schmidtlein, C Ross; Boyko, Vitaly; Fujisawa, Sho; Manova-Todorova, Katia; Zanzonico, Pat; Dauer, Lawrence; Deasy, Joseph O; Humm, John L; Solomon, Stephen

    2018-02-26

    Genomic profiling of biopsied tissue is the basis for precision cancer therapy. However, biopsied materials may not contain sufficient amounts of tumor deoxyribonucleonic acid needed for the analysis. We propose a method to determine the adequacy of specimens for performing genomic profiling by quantifying their metabolic activity. We estimated the average density of tumor cells in biopsy specimens needed to successfully perform genomic analysis following the Memorial Sloan Kettering Integrated Mutation Profiling of Actionable Cancer Targets (MSK-IMPACT) protocol from the minimum amount of deoxyribonucleonic acid needed and the volume of tissue typically used for analysis. The average 18 F-FDG uptake per cell was assessed by incubating HT-29 adenocarcinoma tumor cells in 18 F-FDG containing solution and then measuring their activity with a scintillation well counter. Consequently, we evaluated the response of two devices around the minimum expected activities which would indicate genomic profiling adequacy of biopsy specimens obtained under 18 F-FDG PET/CT guidance. Surrogate samples obtained using 18G core needle biopsies of gels containing either 18 F-FDG-loaded cells in the expected concentrations or the corresponding activity were measured using autoradiography and a scintillation well counter. Autoradiography was performed using a CCD-based device with real-time image display as well as with digital autoradiography imaging plates following a 30-min off-line protocol for specimen activity determination against previously established calibration. Cell incubation experiments and estimates obtained from quantitative autoradiography of biopsy specimens (QABS) indicate that specimens acquired under 18 F-FDG PET/CT guidance that contained the minimum amount of cells needed for genomic profiling would have an average activity concentration in the range of about 3 to about 9 kBq/mL. When exposed to specimens with similar activity concentration, both a CCD

  6. [Bone biopsy needles: mechanical properties, needle design and specimen quality].

    Science.gov (United States)

    Keulers, A; Cunha-Cruz, V C; Bruners, P; Penzkofer, T; Braunschweig, T; Schmitz-Rode, T; Mahnken, A

    2011-03-01

    To quantitatively analyze differences in mechanical properties, needle design including signs of wear, subjective handling and specimen quality of bone biopsy needles. In this study 19 different bone biopsy systems (total 38; 2 /type) were examined. With each biopsy needle five consecutive samples were obtained from vertebral bodies of swine. During puncture a force-torques sensor measured the mechanical properties and subjective handling was assessed. Before and after each biopsy the needles were investigated using a profile projector and signs of wear were recorded. Afterwards, a pathologist semi-quantitatively examined the specimen regarding sample quality. The overall evaluation considered mechanical properties, needle wear, subjective handling and sample quality. Differences were assessed for statistical significance using ANOVA and t-test. Needle diameter (p = 0.003) as well as needle design (p = 0.008) affect the mechanical properties significantly. Franseen design is significantly superior to other needle designs. Besides, length reduction recorded by the profile projector, as a quality criterion showed notable distinctions in between the needle designs. Bone biopsy needles vary significantly in performance. Needle design has an important influence on mechanical properties, handling and specimen quality. Detailed knowledge of those parameters would improve selecting the appropriate bone biopsy needle. © Georg Thieme Verlag KG Stuttgart · New York.

  7. Radial scars without atypia in percutaneous biopsy specimens: can they obviate surgical biopsy?

    Science.gov (United States)

    Mesa-Quesada, J; Romero-Martín, S; Cara-García, M; Martínez-López, A; Medina-Pérez, M; Raya-Povedano, J L

    To evaluate the need for surgical biopsy in patients diagnosed with radial scars without atypia by percutaneous biopsy. In this retrospective observational study, we selected patients with a histological diagnosis of radial scar in specimens obtained by percutaneous biopsy during an 8-year period. The statistical analysis was centered on patients with radial scar without atypia (we assessed the radiologic presentation, the results of the percutaneous biopsy, and their correlation with the results of surgical biopsy and follow-up) and we added the patients with atypia and cancer in the elaboration of the diagnostic indices. We identified 96 patients with radial scar on percutaneous biopsy; 54 had no atypia, 18 had atypia, and 24 had cancer. Among patients with radial scar without atypia, there were no statistically significant differences between patients who underwent imaging follow-up and those who underwent surgical biopsy (p>0.05). The rate of underdiagnosis for percutaneous biopsy in patients without atypia was 1.9%. The rates of diagnosis obtained with percutaneous biopsy in relation to follow-up and surgical biopsy in the 96 cases were sensitivity 92.3%, specificity 100%, positive predictive value 100%, negative predictive value 97.2%, and accuracy 97.9%. The area under the ROC curve was 0.96 (p<0.001), and the kappa concordance index was 0.95 (p<0.001) CONCLUSIONS: We consider that it is not necessary to perform surgical biopsies in patients with radial scars without atypia on percutaneous biopsies because the rate of underestimation is very low and the concordance between the diagnosis reached by percutaneous biopsy and the definitive diagnosis is very high. Copyright © 2017 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.

  8. Gleason Score Correlation Between Prostate Biopsy and Radical Prostatectomy Specimens

    Directory of Open Access Journals (Sweden)

    Erdem Öztürk

    2018-04-01

    Full Text Available Objective: Prostate cancer is the most common malignancy in men and the second cause of cancer-related mortality. Prostate biopsy and the Gleason score guide treatment decisions in prostate cancer. Several studies have investigated the correlation between biopsy scores and radical prostatectomy specimen scores. We also evaluated the correlation of Gleason scores of these specimens in our patient series. Materials and Methods: We retrospectively reviewed the data of 468 men who were diagnosed with prostate cancer and underwent radical prostatectomy between 2008 and 2017. Patients’ age, prostate-specific antigen levels at diagnosis, and prostate biopsy and radical prostatectomy specimen Gleason scores were recorded. Upgrading and downgrading were defined as increase or decrease of Gleason score of radical prostate specimen compared to Gleason score of prostate biopsy. Results: A total of 442 men diagnosed with prostate cancer were included in the study. The mean age of the patients was 62.62±6.26 years (44-84 years and mean prostate specific antigen level was 9.01±6.84 ng/mL (1.09-49 ng/mL. Prostate biopsy Gleason score was 7 in 27 (6.1% men. Radical prostatectomy specimen Gleason score was 7 in 62 (14% men. Gleason correlation was highest in the 240 patients (71.6% with score <7 and was lowest in the 31 (38.75% patients with score =7. Conclusion: This study demonstrated that the discordance rate between Gleason scores of prostate biopsy and radical prostatectomy specimens was 35.7%.

  9. Histology of specimens taken by prostatectomy and needle biopsy ...

    African Journals Online (AJOL)

    Histology of specimens taken by prostatectomy and needle biopsy. P M Ngugi, B Byakika. Abstract. No Abstract. East African Medical Journal Vol. 84 (8) 2007: pp. 363-366. Full Text: EMAIL FREE FULL TEXT EMAIL FREE FULL TEXT · DOWNLOAD FULL TEXT DOWNLOAD FULL TEXT.

  10. Pre-bisection of a single skin biopsy does not produce technically inadequate specimens for direct immunofluorescence: a review of 3450 specimens.

    Science.gov (United States)

    Loh, Ern; Armstrong, April W; Fung, Maxwell A

    2014-11-01

    Evaluation of a potential immunobullous disorder typically requires two pieces of tissue obtained by skin biopsy: one placed in formalin for conventional microscopy and a second placed in a different transport medium suitable for direct immunofluorescence (DIF) testing. Clinical practice in this area is not standardized, with dermatologists either obtaining two biopsies or dividing (pre-bisecting) a single biopsy. Some DIF specimens are technically inadequate for interpretation of subepidermal imunobullous disorders because the basement membrane zone is not intact, but it is unknown whether pre-bisecting the tissue increases the risk of compromising the specimen. To investigate whether technically inadequate DIF specimens are associated with pre-bisection. DIF specimens were consecutively sampled from a single referral center and identified as whole (non-bisected) biopsy specimens or pre-bisected biopsy specimens. The proportion of inadequate specimens was calculated for both groups. A total of 3450 specimens were included. The percentage of inadequate specimens was 5.072% (153/3016) for whole (non-bisected) specimens and 5.299% for pre-bisected specimens. This difference was not significant (chi square, p = 0.84). The study was sufficiently powered to detect a relative risk of 1.685. Pre-bisection of a single skin biopsy does not significantly increase the risk of a technically inadequate specimen for direct immunofluorescence testing. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  11. Hyaluronic acid and HYAL-1 in prostate biopsy specimens: predictors of biochemical recurrence.

    Science.gov (United States)

    Gomez, Christopher S; Gomez, Pablo; Knapp, Judith; Jorda, Merce; Soloway, Mark S; Lokeshwar, Vinata B

    2009-10-01

    Molecular markers could aid prostate specific antigen, biopsy Gleason sum and clinical stage to provide accurate information on prostate cancer progression. HYAL-1 hyaluronidase and hyaluronic acid staining in prostatectomy specimens predicts biochemical recurrence. We examined whether hyaluronic acid and HYAL-1 staining in biopsy specimens predicts biochemical recurrence and correlates with staining in matched prostatectomy specimens. Biopsy and prostatectomy specimens were obtained from 61 patients with clinically localized prostate cancer from multiple centers, including 23 with (group 1) and 38 without (group 2) biochemical recurrence. Mean followup was 103.1 months. Biotinylated hyaluronic acid binding protein and anti-HYAL-1 antibody were used for hyaluronic acid and HYAL-1 staining, respectively. Staining was graded between 0 and 300 depending on staining intensity and area. HYAL-1 and hyaluronic acid were expressed in tumor cells and stroma, respectively. In biopsy specimens HYAL-1 and hyaluronic acid expression was higher in group 1 than in group 2 (203.9 and 182.1 vs 48.8 and 87.0, respectively, p hyaluronic acid, HYAL-1, biopsy Gleason and prostate specific antigen significantly predicted biochemical recurrence (p <0.001). On multivariate analysis only HYAL-1 staining independently predicted recurrence with an accuracy of 81.8% (p <0.001). In prostatectomy specimens only HYAL-1 staining correlated with staining in biopsy specimens (Spearman rho = 0.72, p = 0.0002) and predicted biochemical recurrence. To our knowledge this is the first report that HYAL-1 staining in biopsy specimens is an independent predictor of biochemical recurrence. This may be useful when selecting treatment.

  12. HYALURONIC ACID AND HYAL-1 EXPRESSION IN PROSTATE BIOPSY SPECIMENS: PREDICTORS OF BIOCHEMICAL RECURRENCE

    Science.gov (United States)

    Gomez, Christopher S; Gomez, Pablo; Knapp, Judith; Jorda, Merce; Soloway, Mark S.; Lokeshwar, Vinata B.

    2010-01-01

    Purpose Molecular markers could aid PSA, biopsy Gleason sum and clinical stage in providing accurate information about prostate cancer (CaP) progression. HYAL-1 hyaluronidase and hyaluronic acid (HA) staining in prostatectomy specimens predicts biochemical recurrence. We examined whether HA and HYAL-1 staining in biopsy specimens predicts biochemical recurrence and correlates with the staining in matched prostatectomy specimens. Materials and Methods Biopsy and prostatectomy specimens were obtained from patients with clinically localized CaP (n = 61; mean follow-up = 103.1 months) from multiple centers; Gr. 1: patients with biochemical recurrence (n = 23); Gr. 2: patients without recurrence (n = 38). A biotinylated HA-binding protein and an anti-HYAL-1 antibody were used for HA and HYAL-1 staining. The staining was graded between 0 – 300 depending upon staining intensity and the area. Results HYAL-1 and HA were expressed in tumor cells and stroma, respectively. In biopsy specimens, HYAL-1 and HA expression was higher in Gr.1 (203.9 and 182.1) when compared to Gr. 2 (48.8 and 87.0; P < 0.0001). In univariate analysis, HA, HYAL-1, biopsy Gleason and PSA significantly predicted biochemical recurrence (P < 0.001). In multivariate analysis only HYAL-1 staining was an independent predictor of recurrence (P < 0.001; accuracy: 81.8%). In prostatectomy specimens only HYAL-1 staining correlated with the staining in biopsy specimens (Spearman ρ= 0.72; P = 0.0002), and predicted biochemical recurrence. Conclusion This is the first report that demonstrates that in biopsy specimens HYAL-1 staining is an independent predictor of biochemical recurrence and may be useful in selecting treatment. PMID:19683287

  13. Characterization of Cement Particles Found in Peri-implantitis-Affected Human Biopsy Specimens.

    Science.gov (United States)

    Burbano, Maria; Wilson, Thomas G; Valderrama, Pilar; Blansett, Jonathan; Wadhwani, Chandur P K; Choudhary, Pankaj K; Rodriguez, Lucas C; Rodrigues, Danieli C

    2015-01-01

    Peri-implantitis is a disease characterized by soft tissue inflammation and continued loss of supporting bone, which can result in implant failure. Peri-implantitis is a multifactorial disease, and one of its triggering factors may be the presence of excess cement in the soft tissues surrounding an implant. This descriptive study evaluated the composition of foreign particles from 36 human biopsy specimens with 19 specimens selected for analysis. The biopsy specimens were obtained from soft tissues affected by peri-implantitis around cement-retained implant crowns and compared with the elemental composition of commercial luting cement. Nineteen biopsy specimens were chosen for the comparison, and five test cements (TempBond, Telio, Premier Implant Cement, Intermediate Restorative Material, and Relyx) were analyzed using scanning electron microscopy equipped with energy dispersive x-ray spectroscopy. This enabled the identification of the chemical composition of foreign particles embedded in the tissue specimens and the composition of the five cements. Statistical analysis was conducted using classification trees to pair the particles present in each specimen with the known cements. The particles in each biopsy specimen could be associated with one of the commercial cements with a level of probability ranging between .79 and 1. TempBond particles were found in one biopsy specimen, Telio particles in seven, Premier Implant Cement particles in four, Relyx particles in four, and Intermediate Restorative Material particles in three. Particles found in human soft tissue biopsy specimens around implants affected by peri-implant disease were associated with five commercially available dental cements.

  14. Correlation Between Incisional Biopsy Histological Subtype and a Mohs Surgery Specimen for Nonmelanoma Skin Cancer.

    Science.gov (United States)

    Cortés-Peralta, E C; Ocampo-Candiani, J; Vázquez-Martínez, O T; Gutiérrez-Villarreal, I M; Miranda-Maldonado, I; Garza-Rodríguez, V

    Histological diagnosis of a clinically suspected nonmelanoma skin cancer (NMSC) is recommended before treatment. For NMSC, concordance between the histological subtype of the preoperative biopsy and the excision specimen of basal cell carcinoma (BCC) has been reported to range from 10% to 81%. No large study on the concordance between NMSC histology seen in a preoperative biopsy with the following tumour specimen from Mohs micrographic surgery (MMS) has been performed in a Latin American population. The aim of this study was to analyse and compare the histological subtype of the incisional biopsies reviewed by the dermatopathologist with the histological subtype of the tumour specimen obtained during MMS interpreted by the dermatopathologist and the Mohs surgeon. A retrospective analysis of 320 NMSC was performed. The interobserver correlation was based on kappa values. The mean weighted kappa value between the preoperative NMSC biopsy and intraoperative histological subtype of the tumour specimen from MMS analysed by the Mohs surgeon and the dermatopathologist was 0.22 and 0.24, respectively. The correlation in the histologic subtype of the intraoperative tumour specimen from MMS that was interpreted by the dermatopathologist and Mohs surgeon was 0.58. Dermatologists need to be aware of the limited value of incisional biopsies to accurately diagnose the histological subtype of a NMSC. The concordance rate in the histological diagnosis of the tumour specimens that were obtained from MMS between the Mohs surgeon and the dermatopathologist is moderate. However, the correlation is low compared with incisional biopsy subtypes. Copyright © 2017 AEDV. Publicado por Elsevier España, S.L.U. All rights reserved.

  15. Stereological quantification of immune-competent cells in baseline biopsy specimens from achilles tendons

    DEFF Research Database (Denmark)

    Kragsnaes, Maja Skov; Fredberg, Ulrich; Stribolt, Katrine

    2014-01-01

    BACKGROUND: Limited data exist on the presence and function of immune-competent cells in chronic tendinopathic tendons and their potential role in inflammation and tissue healing as well as in predicting long-term outcome. PURPOSE: To quantify subtypes of immune-competent cells in biopsy specimens....... METHODS: Fifty patients with nonruptured chronic Achilles tendinopathy and 15 healthy participants were included. At time of inclusion, an ultrasound examination was performed immediately before an ultrasound-guided Achilles tendon biopsy specimen was obtained. Tissue samples were evaluated......(+)) using a stereological technique. A follow-up examination was conducted more than 4 years (range, 4-9 years) after the biopsy procedure to evaluate the long-term presence of Achilles tendon symptoms. RESULTS: Macrophages, T lymphocytes, mast cells, and natural killer cells were observed in the majority...

  16. Biopsies

    Science.gov (United States)

    ... vs. risks? What are the limitations of biopsies? What are biopsies? A biopsy is the removal of tissue in order to examine it for disease. The ... lung parenchyma during renal biopsy top of page What are the limitations of ... some cases, the amount of tissue obtained from a needle biopsy may not be ...

  17. A Comprehensive Analysis of Cribriform Morphology on Magnetic Resonance Imaging/Ultrasound Fusion Biopsy Correlated with Radical Prostatectomy Specimens.

    Science.gov (United States)

    Truong, Matthew; Feng, Changyong; Hollenberg, Gary; Weinberg, Eric; Messing, Edward M; Miyamoto, Hiroshi; Frye, Thomas P

    2018-01-01

    Recently a large body of evidence has emerged indicating that cribriform morphology is an aggressive prostate cancer morphological pattern associated with higher cancer specific mortality. In a comprehensive analysis we compared traditional and contemporary prostate biopsy techniques to detect prostate cancer with cribriform morphology with radical prostatectomy serving as the reference standard. We queried a retrospectively maintained, single institution, multiparametric magnetic resonance imaging database of 1,001 patients to identify 240 who underwent magnetic resonance imaging-ultrasound fusion targeted biopsy and concurrent systematic biopsy from December 2014 to December 2016. Of the 3,978 biopsy cores obtained 694 positive cores were rereviewed by a genitourinary pathologist for pattern 4 subtype (cribriform, fused and poorly formed glands). Using paired analysis pathological results among 3 biopsy methods (systematic biopsy, targeted biopsy and systematic plus targeted biopsy) were compared. Prostatectomy specimens were also pathologically reviewed. Systematic plus targeted biopsy was superior to systematic biopsy alone or targeted biopsy alone to detect cribriform morphology (all p <0.0001). On final histopathology cribriform tumor foci were associated with an increased percent of pattern 4 involvement and extraprostatic extension (p <0.0001 and 0.003, respectively). Only 17.4% of cribriform tumors in pure form were visible on multiparametric magnetic resonance imaging. Based on final histopathology the sensitivity of systematic biopsy, targeted biopsy and systematic plus targeted biopsy for cribriform morphology was 20.7%, 28.6% and 37.1%, respectively. Although systematic plus targeted biopsy was the most accurate biopsy method to detect cribriform morphology, biopsy sensitivity and specificity remained poor. Copyright © 2018 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  18. Comparison of Genotyping Helicobacter pylori Directly from Biopsy Specimens and Genotyping from Bacterial Cultures

    OpenAIRE

    Park, Chang-Young; Kwak, Minjung; Gutierrez, Oscar; Graham, David Y.; Yamaoka, Yoshio

    2003-01-01

    PCR for vacA and cagA genotypes of Helicobacter pylori using DNA isolated from infected gastric biopsy specimens was approximately equal to genotyping using bacterial DNA from cultures. Inconsistent results were associated with low H. pylori density in biopsies. A higher proportion of mixed infection was found when biopsies were used.

  19. The diagnosis of cancer in thyroid fine needle aspiration biopsy. Surgery, repeat biopsy or specimen consultation?

    Directory of Open Access Journals (Sweden)

    Agata Stanek-Widera

    2016-05-01

    Full Text Available Fine needle aspiration biopsy (FNA is the only diagnostic method that allows a preoperative diagnosis of thyroid carcinoma. An unequivocal diagnosis of a malignant change is achievable only in cases in which all cytological criteria of carcinoma are met. The aim of the study was to evaluate the necessity of repeat thyroid FNA in patients with papillary thyroid carcinoma verified on consultative examination (CE. We analyzed cytology reports of thyroid FNA and CE that resulted in the diagnosis of papillary carcinoma. Evaluation of the correlation of the cytological diagnosis with the histopathology report was based on data obtained after the surgery. Between 2010 and 2015 in the Institute of Oncology (IO there were 184 cancers diagnosed on CE or in thyroid FNA performed primarily in IO. Additionally, 74 patients were subjected to repeat biopsy after confirmation of cancer in CE. Histopathological diagnosis of cancer was obtained in 62 (100% cases that were doubly confirmed with cytological examination. The remaining 12 patients were operated on outside the institute. From 110 FNA primarily performed in the IO, histopathological verification was achievable in 92 cases, from which 92 (100% provided a confirmation of cancer, and the remaining 18 patients were operated on outside the institute. High (100% specificity of cancer diagnosis in FNA established primarily and verified on CE (second independent assessment indicates that repeat FNA in order to confirm the diagnosis is unnecessary.

  20. Eosinophils are rare in biopsy specimens of psoriasis vulgaris.

    Science.gov (United States)

    Rosa, Gabriela; Fernandez, Anthony P; Schneider, Sarah; Billings, Steven D

    2017-12-01

    Histological features of lesional biopsies can be helpful in distinguishing psoriasis subtypes from disease mimickers. However, occasionally, classic histological features are not sufficient for distinction, and additional clues would be useful. There is a common belief that the presence of eosinophils in skin biopsies argues against psoriasis, but actual literature is scant. Skin biopsies with a diagnosis of psoriasis from 2013 to 2016 were reviewed. For inclusion, both histological and clinical features were required to be consistent with psoriasis. For biopsies meeting inclusion criteria, a detailed evaluation for typical histological parameters of psoriasis, as well as presence of dermal eosinophils, was performed. Of 85 cases meeting inclusion criteria, all had either individual or grouped intracorneal neutrophils and dilated papillary blood vessels. Diminished or complete loss of the granular cell layer was seen in 83 cases (98%), and parakeratosis was seen in 84 cases (99%). Alternatively, dermal eosinophils were seen in only 15 cases (18%). Of cases with eosinophils, none had more than 3 eosinophils upon examination of the entire dermis. Active treatment did not appear to impact presence/absence or numbers of eosinophils. Eosinophils are uncommon in psoriasis biopsies, and when present, they are found in small numbers. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  1. Rotary powered device for bone marrow aspiration and biopsy yields excellent specimens quickly and efficiently.

    Science.gov (United States)

    Swords, Ronan T; Kelly, Kevin R; Cohen, Stephen C; Miller, Larry J; Philbeck, Thomas E; Hacker, Sander O; Spadaccini, Cathy J; Giles, Francis J; Brenner, Andrew J

    2010-06-01

    Recently, a new FDA-cleared battery powered bone marrow biopsy system was developed to allow operators access to the bone marrow space quickly and efficiently. A pre-clinical evaluation of the device (OnControl, Vidacare Corporation, San Antonio, TX, USA) on anesthetized pigs was conducted, in addition to a clinical evaluation in hematology clinic patients requiring a bone marrow biopsy. Twenty-six samples were collected from the swine model. No cellular artifact or thermal damage was reported in any of the samples obtained. For the clinical evaluation of the device, 16 patients were recruited. Mean time from needle contact with skin to needle removal was 38.5 +/- 13.94 seconds. No complications were reported. In this study, the manual and powered samples were equivalent in specimen quality. In the patients evaluated, the device was safe, easy to use and the mean procedural time was significantly faster than previously reported with a manual technique.

  2. Liquid culture medium for the rapid cultivation of Helicobacter pylori from biopsy specimens.

    Science.gov (United States)

    Sainsus, N; Cattori, V; Lepadatu, C; Hofmann-Lehmann, R

    2008-12-01

    The goal of this study was to develop a liquid culture medium for the rapid isolation, cultivation, identification and subsequent antibiotics susceptibility testing of Helicobacter pylori directly from biopsy specimens. Five liquid media were tested: Ham's F-12, Brucella broth, tryptic soybroth, brain heart infusion broth and Mueller-Hinton broth. After optimisation of the medium, it was applied in order to investigate biopsy samples from 150 patients with gastro-duodenal disorders and compared with traditional culture methods, microscopy and an H. pylori-specific TaqMan real-time polymerase chain reaction (PCR). The most reliable and rapid growth of H. pylori, even at a small inoculum size, was obtained in Ham's F-12 medium with 5% horse serum. The developed system allowed the primary isolation of H. pylori in clinical samples and provided 87% sensitivity and 100% specificity.

  3. HER2 Heterogeneity in Gastroesophageal Cancer Detected by Testing Biopsy and Resection Specimens.

    Science.gov (United States)

    Fazlollahi, Ladan; Remotti, Helen E; Iuga, Alina; Yang, Hui-Min; Lagana, Stephen M; Sepulveda, Antonia R

    2017-08-07

    - In advanced gastric, esophageal, and gastroesophageal junction adenocarcinomas (GE-GEJ-AC) that overexpress ERBB2 (erb-b2 receptor tyrosine kinase 2 or HER2), anti-HER2 monoclonal antibody therapy confers survival benefit. To select patients for treatment, HER2 expression and gene amplification are evaluated by immunohistochemistry (IHC) and in situ hybridization. - To determine whether GE-GEJ-AC tested for HER2 on biopsy specimens of a primary tumor show different IHC scores and/or HER2 amplification by in situ hybridization in matched resection specimens, potentially changing therapy eligibility. - Immunohistochemistry and silver in situ hybridization were performed in biopsy and/or resection specimens from 100 patients. HER2 testing was performed in matched resection and biopsy specimens of 15 cases to determine whether GE-GEJ-AC with IHC scores of 0, 1 + , and 2 + in biopsy and resection specimens had different IHC and silver in situ hybridization results. - The IHC 3 + cases showed HER2 amplification in 4 of 5 cases (80%), and IHC scores of 0, 1 + , and 2 + showed 3.5%, 14.3%, and 23.5% HER2 amplification by silver in situ hybridization. Among the 15 paired biopsy and resection specimens, 9 (60%) had at least pT2 stage GE-GEJ-AC with HER2 IHC scores of 0, 1 + , or 2 + in the biopsy, and 2 of those 9 cases (22%) had IHC 3 + and HER2 amplification by silver in situ hybridization on the resection specimen. - Our data suggest that HER2 testing should be repeated on resection specimens of GE-GEJ-AC with HER2 IHC scores of negative (0 and 1 + ) or equivocal (2 + ) and in situ hybridization amplification negative biopsy specimen results to evaluate for HER2 heterogeneity when patients are being considered for anti-HER2 therapy.

  4. Bacteriology of Urine Specimens Obtained from Men with ...

    African Journals Online (AJOL)

    empiric use of antibiotics in this group of patients. KEYWORDS: Bacteriuria, benign prostatic hyperplasia, urinary tract infection. How to cite this article: Agbugui JO, Obarisiagbon EO, Osaigbovo II. Bacteriology of Urine Specimens Obtained from Men with Symptomatic. Benign Prostatic Hyperplasia. Niger J Surg 0;0:0.

  5. Lessons learned from the comparative study between renal mass biopsy and the analysis of the surgical specimen.

    Science.gov (United States)

    Domínguez-Esteban, M; Villacampa-Aubá, F; Garcia-Muñóz, H; Tejido Sánchez, A; Romero Otero, J; de la Rosa Kehrmann, F

    2014-12-01

    The role of renal mass (RM) biopsy is currently under discussion. As a result of the progressive increase in the incidental diagnosis of RMs (which have a higher percentage of benignity and well-differentiated cancers), new approaches have emerged such as observation, especially with elderly patients or those with significant comorbidity. RM biopsy (RMB) should provide sufficient information for making this decision, but so far this has not been the case. We examine our prospective series of in-bench RMBs after surgery and compare them with the anatomy of the removed specimen. We obtained (prospectively, in-bench and with a 16-gauge needle) 4 biopsies of RMs operated on in our department from October 2008 to December 2009. These RMs were analyzed by 2 uropathologists and compared with the results of the specimen. We analyzed 188 biopsies (47 RMs); 12.75% were "not valid". The ability of biopsy to diagnose malignancy or benignity was 100%, and the coincidence in the histological type was 95%. The success in determining the tumor grade was 100% when the cancer was low-grade and 62% when high-grade. None of the analyzed data (necrosis, size, etc.) influenced the results in a statistically significant manner. RMB with a 16-G needle enables the differentiation between malignancy and benignity in 100% of cases, with a very similar diagnostic accuracy in the tumor type. Tumor grade is still the pending issue with renal mass biopsy. Copyright © 2014 AEU. Published by Elsevier Espana. All rights reserved.

  6. Electron microscopic examination of skin and conjunctival biopsy specimens in neuronal storage diseases.

    Science.gov (United States)

    Yamano, T; Shimada, M; Okada, S; Yutaka, T; Yabuuchi, H; Nakao, Y

    1979-01-01

    Skin and conjunctival biopsy specimens from fourteen patients with neuronal storage diseases were investigated using an electron microscope. The diseases were Tay-Sachs disease, ceroid-lipofuscinosis (Jansky-Bielschowsky type), Niemann-Pick disease (type B), highly suspected adrenoleukodystrophy, I-cell disease, mucolipidosis of the beta-galactosidase deficient type, Hurler disease, Hunter disease and Morquio disease. This examination provided valuable diagnostic information on some neuronal storage diseases but not on Morquio disease or highly suspected adrenoleukodystrophy. False negative results may sometimes occur using this examination method. However, this examination suggests the usefulness of skin and conjunctival biopsy specimens as a diagnostic tool in some neuronal storage diseases.

  7. Application of low-vacuum scanning electron microscopy for renal biopsy specimens.

    Science.gov (United States)

    Miyazaki, Hiroki; Uozaki, Hiroshi; Tojo, Akihiro; Hirashima, Sayuri; Inaga, Sumire; Sakuma, Kei; Morishita, Yasuyuki; Fukayama, Masashi

    2012-09-15

    Low-vacuum scanning electron microscopy (LV-SEM) has been developed which enables the observation of soft, moist, and electrically insulating materials without any pretreatment unlike conventional scanning electron microscopy, in which samples must be solid, dry and usually electrically conductive. The purpose of this study was to assess the usefulness of LV-SEM for renal biopsy specimens. We analyzed 20 renal biopsy samples obtained for diagnostic purposes. The sections were stained with periodic acid methenamine silver to enhance the contrast, and subsequently examined by LV-SEM. LV-SEM showed a precise and fine structure of the glomerulus in both formalin fixed paraffin and glutaraldehyde-osmium tetroxide-fixed epoxy resin sections up to 10,000-fold magnification. The spike formation on the basement membrane was clearly observed in the membranous nephropathy samples. Similarly to transmission electron microscopy, electron dense deposits were observed in the epoxy resin sections of the IgA nephropathy and membranous nephropathy samples. LV-SEM could accurately show various glomerular lesions at high magnification after a simple and rapid processing of the samples. We consider that this is a novel and useful diagnostic tool for renal pathologies. Copyright © 2012 Elsevier GmbH. All rights reserved.

  8. Radiofrequency identification specimen tracking in anatomical pathology: pilot study of 1067 consecutive prostate biopsies.

    Science.gov (United States)

    Bostwick, David G

    2013-10-01

    Improved methods such as radiofrequency identification (RFID) are needed to optimize specimen tracking in anatomical pathology. We undertook a study of RFID in an effort to optimize specimen tracking and patient identification, including the following: (1) creation of workflow process maps, (2) evaluation of existing RFID hardware technologies, (3) creation of Web-based software to support the RFID-enabled workflow, and (4) assessment of the impact with a series of prostate biopsies. We identified multiple steps in the workflow process in which RFID enhanced specimen tracking. Multiple product choices were found that could withstand the harsh heat and chemical environments encountered in pathology processing, and software that was compatible with our laboratory information system was designed in-house. A total of 1067 prostate biopsies were received, and 78.3% were successfully processed with the RFID system. Radiofrequency identification allowed dynamic specimen tracking throughout the workflow process in anatomical pathology. Copyright © 2013. Published by Elsevier Inc.

  9. Well-differentiated prostate cancer in core biopsy specimens may be associated with extraprostatic disease

    Directory of Open Access Journals (Sweden)

    José Cury

    Full Text Available CONTEXT AND OBJECTIVE: Accurate determination of the Gleason score in prostate core biopsy specimens is crucial in selecting the type of prostate cancer treatment, especially for patients with well-differentiated tumors (Gleason score 2 to 4. For such patients, an inaccurate biopsy score may result in a therapeutic intervention that is too conservative. We evaluate the role of Gleason score 2-4 in prostate core-needle biopsies for predicting the final pathological staging following radical prostatectomy. DESIGN AND SETTING: Retrospective study at Hospital das Clínicas, Faculdade de Medicina da Universidade de São Paulo. METHODS: We analyzed the medical records of 120 consecutive patients who underwent radical retropubic prostatectomy to treat clinical localized prostate cancer at our institution between December 2001 and July 2006. Thirty-two of these patients presented well-differentiated tumors (Gleason score 2 to 4 in biopsy specimens and were included in the study. The Gleason scores of the core-needle biopsies were compared with the pathological staging of the surgical specimens. RESULTS: Sixteen of the 32 patients (50% presented moderately differentiated tumors (Gleason score 5 to 7 in surgical specimens. Eighteen patients (56% had tumors with involvement of the prostate capsule and ten (31% had involvement of adjacent organs. Evaluating the 16 patients that maintained Gleason scores of 2 to 4 in the pathological staging of the surgical specimens, 11 (68.7% had focal invasion of the prostate capsule and five (31.25% had organ-confined disease. CONCLUSION: Well-differentiated tumors (Gleason score 2 to 4 seen in biopsies are not predictive of organ-confined disease.

  10. Identification of EGFR Mutations by Immunohistochemistry with EGFR Mutation-Specific Antibodies in Biopsy and Resection Specimens from Pulmonary Adenocarcinoma.

    Science.gov (United States)

    Kim, Chi Hong; Kim, Seung Hoon; Park, Sonya Youngju; Yoo, Jinyoung; Kim, Sung Kyoung; Kim, Hoon Kyo

    2015-10-01

    Mutation-specific antibodies have recently been developed for identification of epidermal growth factor receptor (EGFR) mutations by immunohistochemistry (IHC). This study was designed to investigate whether the type of specimen (biopsy vs. resection) would make a difference in determining mutation status by IHC, and to evaluate whether biopsies are suitable for detection of mutant EGFR protein. IHC was performed using mutation-specific antibodies for E746-A750 deletion (DEL) and L858R point mutation (L858R) in biopsies and tissue microarrays of resected tumors from 154 patients with pulmonary adenocarcinoma. Results were then compared with DNA sequencing data. Molecular-based assays detected EGFR mutations in 62 patients (40.3%), including 14 (9.1%) with DEL, and 31 (20.1%) with L858R. IHC with two mutation-specific antibodies showed a homogeneous staining pattern, and correctly identified EGFR mutation status in 89% (137/154). Overall (biopsy/resection) sensitivity, specificity, positive predictive value, and negative predictive value were 75.6% (78.3%/72.7%), 94.5% (90.9%/96.3%), 85% (78.3%/88.9%), and 90.4% (90.9%/89.7%), respectively. Our data showed that IHC using EGFR mutation-specific antibodies is useful for detection of EGFR mutations with high specificity and good sensitivity not only for resection specimens but also for biopsy materials. Therefore, IHC using EGFR mutation-specific antibodies may preclude a second biopsy procedure to obtain additional tissues for identification of EGFR mutations by molecular assays in biopsies from advanced cancer, particularly when tumor cells in the samples are limited.

  11. Specimen Provenance Testing Identifies Contamination That Affects Molecular Prognostic Assay Results in Prostate Cancer Biopsy Specimens.

    Science.gov (United States)

    Wojno, Lathem; Minutella, Caitlyn; Moylan, Donald; Bush, Arla; Wojno, Kirk

    2018-02-21

    To determine if tissue contamination in histologic specimens can significantly affect the results of prognostic molecular markers that are routinely used as confirmatory tests to safely assign appropriate candidates to prostate cancer active surveillance protocols. This study evaluates 2,134 cases from a single, large urology practice that were successfully tested for DNA specimen provenance verification using short tandem repeat analysis for the presence of a significant level of contaminating DNA. After removal of the contamination, five of the samples were retested, and the results of the molecular diagnostic test were compared. 49 of the 2,134 cases (2.3%) sent for DNA provenance analysis were found to possess significant levels of contamination. Of these 49 cases, seven of them were resent for a repeat molecular diagnostic test after being decontaminated. Five of these prostate cancer specimens had sufficient tissue and RNA to give a more accurate cell cycle progression (CCP) score. The average absolute change in these patient's CCP scores was 0.48, with a low of a 0.1-unit and a high of a 1.0-unit difference. These changes in CCP scores are significant enough to cause meaningful alterations in a patient's calculated 10-year mortality rate, as defined by their combined risk score (CRS). DNA contamination in unstained tissue sections sent for prognostic prostate cancer molecular diagnostic testing occurs on 2.3% of cases, and can be of a magnitude that affects the results and subsequent clinical decision of appropriateness for active surveillance. Copyright © 2018. Published by Elsevier Inc.

  12. CT-Guided Transthoracic Core Biopsy for Pulmonary Tuberculosis: Diagnostic Value of the Histopathological Findings in the Specimen

    International Nuclear Information System (INIS)

    Fukuda, Hozumi; Ibukuro, Kenji; Tsukiyama, Toshitaka; Ishii, Rei

    2004-01-01

    We evaluated the value of CT-guided transthoracic core biopsy for the diagnosis of mycobacterial pulmonary nodules. The 30 subjects in this study had pulmonary nodules that had been either diagnosed histopathologically as tuberculosis or were suspected as tuberculosis based on a specimen obtained by CT-guided transthoracic core biopsy. The histopathological findings, the existence of acid-fast bacilli in the biopsy specimens, and the clinical course of the patients after the biopsy were reviewed retrospectively. Two of the three histological findings for tuberculosis that included epithelioid cells, multinucleated giant cells and caseous necrosis were observed in 21 of the nodules which were therefore diagnosed as histological tuberculosis. Six of these 21 nodules were positive for acid-fast bacilli, confirming the diagnosis of tuberculosis. Thirteen of the 21 nodules did not contain acid-fast bacilli but decreased in size in response to antituberculous treatment and were therefore diagnosed as clinical tuberculosis. Seven nodules with only caseous necrosis were diagnosed as suspected tuberculosis, with a final diagnosis of tuberculosis being made in 4 of the nodules and a diagnosis of old tuberculosis in 2 nodules. Two nodules with only multinucleated giant cells were diagnosed as suspected tuberculosis with 1 of these nodules being diagnosed finally as tuberculosis and the other nodule as a nonspecific granuloma. When any two of the three following histopathological findings - epithelioid cells, multinucleated giant cells or caseous necrosis - are observed in a specimen obtained by CT-guided transthoracic core biopsy, the diagnosis of tuberculosis can be established without the detection of acid-fast bacilli or Mycobacterium tuberculosis

  13. Frequency of residual melanoma in wide local excision (WLE) specimens after complete excisional biopsy.

    Science.gov (United States)

    Bolshinsky, Vladimir; Lin, Matthew J; Serpell, Jonathan; Leung, Michael; Wolfe, Rory; McLean, Catriona; Kelly, John W

    2016-01-01

    We sought to better understand the role of wide local excision (WLE) in the treatment of cutaneous melanoma by analyzing residual or locally metastatic disease in WLE specimens of melanomas initially diagnosed with a complete excisional biopsy. This was a retrospective review of 807 consecutive WLEs of melanomas diagnosed after complete excisional biopsy. All specimens were reviewed by a single dermatopathologist. Risk of residual or locally metastatic disease was analyzed using univariate and multivariate logistic regression models. In the 807 WLE specimens, further melanoma was found in 34 cases (4.2%; 95% confidence interval [CI] 2.9-5.8). Residual primary melanoma was found in 33 of these. On univariate analysis, features associated with residual or locally metastatic disease were histologic subtype (odds ratio 3.0; 95% CI 1.3-7.1, P = .01) and tumor location (odds ratio 7.3; 95% CI 2.0-26.6, P melanoma remaining in WLE specimens (odds ratio 2.7; 95% CI 1.0-7.3, P = .04). Residual melanoma in WLE specimens after histologically assessed complete excisional biopsy is not uncommon. Patients with lentigo maligna subtype melanomas are most at risk. Our findings indicate that the procedure of WLE is most important therapeutically for its role in controlling the primary tumor, rather than in preventing local metastatic recurrence. Crown Copyright © 2015. Published by Elsevier Inc. All rights reserved.

  14. Relationship between thallium-201 myocardial SPECT and findings of endomyocardial biopsy specimens in dilated cardiomyopathy

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, Motohiro; Gotoh, Kohshi; Nagashima, Kenshi [Gifu Univ. (Japan). School of Medicine] (and others)

    2001-02-01

    The purpose of this study was to clarify which myocardial histological findings associated with dilated cardiomyopathy (DCM) are reflected in quantitative {sup 201}Tl myocardial SPECT. We obtained studied SPECT images from 21 patients with DCM 10 minutes and 2 hours after they received an injection of 111 MBq {sup 201}Tl at rest. We calculated the percent coefficient of variation of myocardial {sup 201}Tl counts [%CV(Tl)], the washout rate (WR), standard deviation of WR [SD(WR)], extent score (ES) and severity score (SS). We used image analysis to measure % fibrosis, % myocytes, the ratio of fibrous tissue to myocyte tissue (F/My), myocyte size and standard deviation of myocyte size [SD(My)] in left ventricular endomyocardial biopsy specimens. The %CV(Tl) was correlated with % fibrosis and F/My. The ES and SS also correlated with F/My. The correlation between SD(WR) and SD(My) was significant. The present findings suggest that %CV(Tl), ES and SS of rest {sup 201}Tl SPECT reflect myocardial fibrosis and that the standard deviation of washout reflects the distribution of myocyte size. (author)

  15. Concordance of DNA methylation profiles between breast core biopsy and surgical excision specimens containing ductal carcinoma in situ (DCIS).

    Science.gov (United States)

    Chen, Youdinghuan; Marotti, Jonathan D; Jenson, Erik G; Onega, Tracy L; Johnson, Kevin C; Christensen, Brock C

    2017-08-01

    The utility and reliability of assessing molecular biomarkers for translational applications on pre-operative core biopsy specimens assume consistency of molecular profiles with larger surgical specimens. Whether DNA methylation in ductal carcinoma in situ (DCIS), measured in core biopsy and surgical specimens are similar, remains unclear. Here, we compared genome-scale DNA methylation measured in matched core biopsy and surgical specimens from DCIS, including specific DNA methylation biomarkers of subsequent invasive cancer. DNA was extracted from guided 2mm cores of formalin fixed paraffin embedded (FFPE) specimens, bisulfite-modified, and measured on the Illumina HumanMethylation450 BeadChip. DNA methylation profiles of core biopsies exhibited high concordance with matched surgical specimens. Within-subject variability in DNA methylation was significantly lower than between-subject variability (all Pcore biopsy and surgical specimens, 15%, and a pathway analysis of these CpGs indicated enrichment for genes related with wound healing. Our results indicate that DNA methylation measured in core biopsies are representative of the matched surgical specimens and suggest that DCIS biomarkers measured in core biopsies can inform clinical decision-making. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  16. Genomic Characterization and Comparison of Multi-Regional and Pooled Tumor Biopsy Specimens.

    Directory of Open Access Journals (Sweden)

    Je-Gun Joung

    Full Text Available A single tumor biopsy specimen is typically used in cancer genome studies. However, it may represent incompletely the underlying mutational and transcriptional profiles of tumor biology. Multi-regional biopsies have the advantage of increased sensitivity for genomic profiling, but they are not cost-effective. The concept of an alternative method such as the pooling of multiple biopsies is a challenge. In order to determine if the pooling of distinct regions is representative at the genomic and transcriptome level, we performed sequencing of four regional samples and pooled samples for four cancer types including colon, stomach, kidney and liver cancer. Subsequently, a comparative analysis was conducted to explore differences in mutations and gene expression profiles between multiple regional biopsies and pooled biopsy for each tumor. Our analysis revealed a marginal level of regional difference in detected variants, but in those with low allele frequency, considerable discrepancies were observed. In conclusion, sequencing pooled samples has the benefit of detecting many variants with moderate allele frequency that occur in partial regions, but it is not applicable for detecting low-frequency mutations that require deep sequencing.

  17. Banff study of pathologic changes in lung allograft biopsy specimens with donor-specific antibodies

    DEFF Research Database (Denmark)

    Wallace, William Dean; Li, Ning; Andersen, Claus B

    2016-01-01

    a statistically significant difference vs NABs in the setting of acute lung injury, with or without diffuse alveolar damage (p = 0.0008), in the presence of capillary neutrophilic inflammation (p = 0.0014), and in samples with endotheliitis (p = 0.0155). In samples with complement 4d staining, there was a trend......-DSAs, and no antibodies (NABs) present. The significance of each histologic variable was reviewed. RESULTS: We found no statistically significant association with acute cellular rejection, airway inflammation, or bronchiolitis obliterans and the presence or absence of antibodies. However, biopsy specimens with DSAs had...... but no statistically significant difference between specimens associated with DSAs and specimens with NABs. CONCLUSIONS: Capillary inflammation, acute lung injury, and endotheliitis significantly correlated with DSAs. The infrequently observed diffuse staining for complement 4d limits the usefulness of this stain....

  18. Optimization of initial prostate biopsy in clinical practice: sampling, labeling and specimen processing.

    Science.gov (United States)

    Bjurlin, Marc A; Carter, H Ballentine; Schellhammer, Paul; Cookson, Michael S; Gomella, Leonard G; Troyer, Dean; Wheeler, Thomas M; Schlossberg, Steven; Penson, David F; Taneja, Samir S

    2013-06-01

    An optimal prostate biopsy in clinical practice is based on a balance among adequate detection of clinically significant prostate cancers (sensitivity), assuredness regarding the accuracy of negative sampling (negative predictive value), limited detection of clinically insignificant cancers and good concordance with whole gland surgical pathology results to allow accurate risk stratification and disease localization for treatment selection. Inherent within this optimization is variation of the core number, location, labeling and processing for pathological evaluation. To date, there is no consensus in this regard. The purpose of this review is to 1) define the optimal number and location of biopsy cores during primary prostate biopsy among men with suspected prostate cancer, 2) define the optimal method of labeling prostate biopsy cores for pathological processing which will provide relevant and necessary clinical information for all potential clinical scenarios, and 3) determine the maximal number of prostate biopsy cores allowable within a specimen jar which would not preclude accurate histological evaluation of the tissue. A bibliographic search using PubMed® covering the period up to July 2012 yielded approximately 550 articles. Articles were reviewed and categorized based on which of the 3 objectives of this review was addressed. Data were extracted, analyzed and summarized. Recommendations are provided based on this literature review and our clinical experience. The use of 10 to 12-core extended sampling protocols increases cancer detection rates compared to traditional sextant sampling methods and reduces the likelihood of repeat biopsy by increasing negative predictive value, ultimately allowing more accurate risk stratification without increasing the likelihood of detecting insignificant cancers. As the number of cores increases above 12, the increase in diagnostic yield becomes marginal. Only limited evidence supports the use of initial biopsy schemes

  19. High sensitivity of late gadolinium enhancement for predicting microscopic myocardial scarring in biopsied specimens in hypertrophic cardiomyopathy.

    Directory of Open Access Journals (Sweden)

    Tetsuo Konno

    Full Text Available BACKGROUND: Myocardial scarring can be assessed by cardiac magnetic resonance imaging with late gadolinium enhancement and by endomyocardial biopsy. However, accuracy of late gadolinium enhancement for predicting microscopic myocardial scarring in biopsied specimens remains unknown in hypertrophic cardiomyopathy. We investigated whether late gadolinium enhancement in the whole heart reflects microscopic myocardial scarring in the small biopsied specimens in hypertrophic cardiomyopathy. METHODS AND RESULTS: Twenty-one consecutive patients with hypertrophic cardiomyopathy who were examined both by cardiac magnetic resonance imaging and by endomyocardial biopsy were retrospectively studied. The right interventricular septum was the target site for endomyocardial biopsy in all patients. Late gadolinium enhancement in the ventricular septum had an excellent sensitivity (100% with a low specificity (40% for predicting microscopic myocardial scarring in biopsied specimens. The sensitivity of late gadolinium enhancement in the whole heart remained 100% with a specificity of 27% for predicting microscopic myocardial scarring in biopsied specimens. Quantitative assessments of fibrosis revealed that the extent of late gadolinium enhancement in the whole heart was the only independent variable related to the microscopic collagen fraction in biopsied specimens (β  =  0.59, 95% confident interval: 0.15 - 1.0, p  =  0.012. CONCLUSIONS: Although there was a compromise in the specificity, the sensitivity of late gadolinium enhancement was excellent for prediction of microscopic myocardial scarring in hypertrophic cardiomyopathy. Moreover, the severity of late gadolinium enhancement was independently associated with the quantitative collagen fraction in biopsied specimens in hypertrophic cardiomyopathy. These findings indicate that late gadolinium enhancement can reflect both the presence and the extent of microscopic myocardial scarring in the small

  20. Morphological study of Pipelle biopsy specimens in cases of abnormal uterine bleeding.

    Science.gov (United States)

    Khadim, Muhammad Tahir; Zehra, Talat; Ashraf, Hafiz Murtuza

    2015-07-01

    To determine the frequencies of common morphological patterns of abnormal uterine bleeding on Pipelle biopsy specimen. The cross-sectional study was conducted at PNS Shifa Hospital, Karachi, and comprised endometrial Pipelle biopsies of patients with abnormal uterine bleeding received between January 2013 and January 2014. Patient's age, marital status, parity and histopatholgical spectrum were recorded. SPSS 17 was used for data analysis. Of the 101 patients, 53(52.50%) presented with proliferative endometrium, 22(21.80%) had secretory endometrium, 13(12.9%) presented with chronic non-specific endometritis, 8(7.9%) had endometrial hyperplasia without atypia, and 5(5%) had endometrial hyperplasia with atypia. Besides, 86(85.1 %) were nulliparous; 15(14.9%) were parous; 92(91.1%) were married and 9(8.9%) were unmarried. The most common morphological pattern was proliferative endometrium. Though Pipelle has its own limitations, it performed better when endometrial pathology was global rather than focal.

  1. Significant histologic features differentiating cellular fibroadenoma from phyllodes tumor on core needle biopsy specimens.

    Science.gov (United States)

    Yasir, Saba; Gamez, Roberto; Jenkins, Sarah; Visscher, Daniel W; Nassar, Aziza

    2014-09-01

    Cellular fibroepithelial lesions (CFELs) are a heterogeneous group of tumors encompassing cellular fibroadenoma (CFA) and phyllodes tumor (PT). Distinction between the two is challenging on core needle biopsy (CNB) specimens. The objective of this study was to evaluate histologic features that can help distinguish PT from CFA on CNB specimens. Records of all patients diagnosed with CFELs on CNB specimens with follow-up excision between January 2002 and December 2012 were retrieved. Histopathologic stromal features were evaluated on CNB specimens, including mitoses per 10 high-power fields (hpf), overgrowth, increased cellularity, fragmentation, adipose tissue infiltration, heterogeneity, subepithelial condensation, and nuclear pleomorphism. Twenty-seven (42.2%) of 64 were diagnosed as PT (24 benign PTs and three borderline PTs) and 37 (57.8%) as CFA on excision. All features except for increased stromal cellularity were statistically significant. The average number of histologic features seen in PT and CFA was 3.9 and 1.4, respectively (odds ratio [OR], 7.27; 95% confidence interval [CI], 2.44-21.69; P = .0004). The average number of mitoses per 10 hpf was 3.0 for PT compared with 0.8 for CFA (OR, 2.14; 95% CI, 1.18-3.86; P = .01). The presence of mitoses (three or more) and/or total histologic features of three or more on CNB specimens were the most helpful features in predicting PT on excision. Copyright© by the American Society for Clinical Pathology.

  2. Diagnostic value of immunoperoxidase staining and immunofluorescence in the study of kidney biopsy specimens.

    Science.gov (United States)

    Jafari, Mohammad; Monsef-Esfahani, Alireza; Solimani, Bahram

    2015-07-01

    This study aimed to determine diagnostic value of immunoperoxidase in comparison with immunofluorescence in the diagnostic assessment of kidney biopsy specimens. Forty-eight kidney biopsy specimens were used to compare a direct immunofluorescence technique with immunoperoxidase techniques on paraffin sections. The sensitivity and specificity were calculated. The kappa statistic for agreement between the two tests was categorized as poor (zero to 0.2), moderate (0.21 to 0.45), good (0.46 to 0.75), and almost perfect concordance (0.76 to 1.0). Compared with immunofluorescence, the immunoperoxidase technique presented a sensitivity of 88.55% and a specificity of 69.22%. Its sensitivity in the staining for IgG, IgM, and IgA was 93.75%, 95.45%, and 76.47%, respectively. The specificity of this test in the staining for IgG, IgM, and IgA was 54.54%, 57.14%, and 96.00%, respectively. The overall kappa value was 0.60 and it was 0.60 for assessing staining intensity. There was a moderate agreement between immunoperoxidase and immunofluorescence in the positive or negative staining for IgG and IgM, as well as a good agreement in the positive or negative staining for IgA. For the staining intensity, the two tests had a good concordance for IgG and IgA and a moderate concordance for IgM. Although immunoperoxidase method has a lower overall diagnostic performance as compared to immunofluorescence, given the good concordance between the two techniques, it can be an alternative method for immunofluorescence study of kidney biopsy specimens, particularly where immunofluorescence fails or is not available.

  3. Intestinal Bacterial Infection Diagnosed by Histological Examination of Endoscopic Biopsy Specimens

    Directory of Open Access Journals (Sweden)

    Michiko Yuki

    2016-10-01

    Full Text Available Intestinal spirochetosis (IS in humans is characterized by spirochetal microorganisms attached to the luminal surface of the colonic epithelium. In the present case, attached organisms appeared as 3- to 4 μm-thick (average thickness, 3.4 μm basophilic fringes or haze in HE-stained endoscopic biopsy specimens. The basophilic fringes were clearly labeled by Treponema pallidum antiserum. Because IS is relatively rare in developed countries, thin basophilic fringes characteristic of IS are readily overlooked. Thus, the recognition of histological characteristics of this disease is important for its diagnosis.

  4. Evaluation of polymerase chain reaction in nerve biopsy specimens of patients with Hansen's disease.

    Science.gov (United States)

    Tiwari, Vandana; Malhotra, Kiranpreet; Khan, Kainat; Maurya, Pradeep K; Singh, Ajai Kumar; Thacker, Anup Kumar; Husain, Nuzhat; Kulshreshtha, Dinkar

    2017-09-15

    Pure neuritic variety of leprosy (PNL) presents as peripheral neuropathy with absent skin lesions and negative skin smears. Diagnosing PNL is an uphill task as most of these patients have nonspecific changes on nerve biopsy. In such circumstances, additional molecular diagnostic tools like polymerase chain reaction (PCR) has proven to be useful in diagnosing leprosy. The present study was planned to evaluate the role of PCR in nerve biopsy specimens of patients with PNL. Patients attending the neuromuscular clinic from January 2013 to June 2014 with mononeuropathy multiplex underwent detailed diagnostic evaluation to ascertain the cause of neuropathy. Patients where this evaluation failed to establish an etiology underwent a nerve biopsy. Nerve biopsy was done in 52 patients, of which 35 were diagnosed as pure neuritic leprosy. Definite leprosy with positive wade fite staining for lepra bacilli was seen in 13 patients and 22 biopsies revealed a probable leprosy without lepra bacilli being identified. PCR for M. leprae was positive in 22 patients (62%). 12 of the 13 cases with definite leprosy on histopathology were PCR positive while in the AFB negative group, PCR was positive in 10 cases. PCR had a sensitivity of 92.3%, specificity of 54.5%. The positive and negative predictive value of PCR was 54.5% and 92.3% respectively. PCR helps in diagnosing PNL in doubtful cases. A positive PCR increases the sensitivity of detection of M. leprae especially in cases of probable PNL group where AFB cannot be demonstrated on histopathology. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. High prevalence of herpes simplex virus DNA in temporal arteritis biopsy specimens.

    Science.gov (United States)

    Powers, James F; Bedri, Shahinaz; Hussein, Shakir; Salomon, Robert N; Tischler, Arthur S

    2005-02-01

    Giant cell arteritis (GCA) affecting the cranial arteries is a disease of unknown cause that causes blindness, stroke, and other morbidity. Its sudden onset and segmental distribution are suggestive of diseases that involve viral reactivation, and cranial arteries are known to be innervated by ganglia that harbor herpes simplex virus (HSV). We used a high-sensitivity polymerase chain reaction assay to test for HSV DNA in specimens from 39 consecutive temporal artery biopsies performed for suspected GCA. HSV DNA was detected in 21 (88%) of 24 histologically positive and 8 (53%) of 15 histologically negative specimens (P = .027; Fisher exact test). Analysis of 10 renal artery samples from age-matched control subjects using the same assay showed no detectable HSV DNA. We conclude that detectable HSV DNA is correlated with histologically confirmed GCA in this patient population.

  6. Risk Factors Associated with Discordant Ki-67 Levels between Preoperative Biopsy and Postoperative Surgical Specimens in Breast Cancers

    OpenAIRE

    Kim, Hyung Sun; Park, Seho; Koo, Ja Seung; Kim, Sanghwa; Kim, Jee Ye; Nam, Sanggeun; Park, Hyung Seok; Kim, Seung Il; Park, Byeong-Woo

    2016-01-01

    Purpose The Ki-67 labelling index is significant for the management of breast cancer. However, the concordance of Ki-67 expression between preoperative biopsy and postoperative surgical specimens has not been well evaluated. This study aimed to find the correlation in Ki-67 expression between biopsy and surgical specimens and to determine the clinicopathological risk factors associated with discordant values. Patients and Methods Ki-67 levels were immunohistochemically measured using paired b...

  7. Genome-Wide Analysis of 18 Epstein-Barr Viruses Isolated from Primary Nasopharyngeal Carcinoma Biopsy Specimens.

    Science.gov (United States)

    Tu, Chaofeng; Zeng, Zhaoyang; Qi, Peng; Li, Xiayu; Yu, Zhengyuan; Guo, Can; Xiong, Fang; Xiang, Bo; Zhou, Ming; Gong, Zhaojian; Liao, Qianjin; Yu, Jianjun; He, Yi; Zhang, Wenling; Li, Xiaoling; Li, Yong; Li, Guiyuan; Xiong, Wei

    2017-09-01

    Epstein-Barr virus (EBV) is a ubiquitous gammaherpesvirus that is highly prevalent in almost all human populations and is associated with many human cancers, such as nasopharyngeal carcinoma (NPC), Hodgkin's disease, and gastric carcinoma. However, in these EBV-associated cancers, only NPC exhibits remarkable ethnic and geographic distribution. We hypothesized that EBV genomic variations might contribute to the pathogenesis of different human cancers in different geographic areas. In this study, we collected 18 NPC biopsy specimens from the Hunan Province in southern China and de novo assembled 18 NPC biopsy specimen-derived EBV (NPC-EBV) genomes, designated HN1 to HN18. This was achieved through target enrichment of EBV DNA by hybridization, followed by next-generation sequencing, to reveal sequence diversity. These EBV genomes harbored 20,570 variations totally, including 20,328 substitutions, 88 insertions, and 154 deletions, compared to the EBV reference genome. Phylogenetic analysis revealed that all NPC-EBV genomes were distinct from other EBV genomes. Furthermore, HN1 to HN18 had some nonsynonymous variations in EBV genes including genes encoding latent, early lytic, and tegument proteins, such as substitutions within transmembrane domains 1 and 3 of LMP1, FoP_duplication, and zf-AD domains of ENBA1, in addition to aberrations in noncoding regions, especially in BamHI A rightward transcript microRNAs. These variations might have potential biological significance. In conclusion, we reported a genome-wide view of sequence variation in EBV isolated from primary NPC biopsy specimens obtained from the Hunan Province. This might contribute to further understanding of how genomic variations contribute to carcinogenesis, which would impact the treatment of EBV-associated cancer. IMPORTANCE Nasopharyngeal carcinoma (NPC) is highly associated with Epstein-Barr virus (EBV) infection and exhibits remarkable ethnic and geographic distribution. Hunan Province in southern

  8. Are biomarkers evaluated in biopsy specimens predictive of prostate cancer aggressiveness?

    Science.gov (United States)

    Carozzi, Francesca; Tamburrino, Lara; Bisanzi, Simonetta; Marchiani, Sara; Paglierani, Milena; Di Lollo, Simonetta; Crocetti, Emanuele; Buzzoni, Carlotta; Burroni, Elena; Greco, Luana; Baldi, Elisabetta; Sani, Cristina

    2016-01-01

    To evaluate biomarkers involved in biological pathways for prostate cancer (PCa) progression, measured in biopsy specimens, in order to distinguish patients at higher risk for fatal PCa and thus improve the initial management of disease. Retrospective case-control study. In 129 PCa patients who underwent ultrasound-guided needle prostate biopsy and subsequent radical prostatectomy from 1987 to 1999 at the University Hospital of Careggi, we evaluated: (1) mRNA expression of the serine 2 (TMPRSS2): erythroblastosis virus E26 oncogene homolog (ERG); (2) expression of matrix metalloproteinases (MMP)-2 and 9 (epithelial and stromal); (3) expression of androgen receptor; (4) expression of prognostic marker Ki67 (MIB1); (5) presence and typing of human papilloma virus; (6) DNA methylation of CpG islands of several genes involved in PCa progression. The cohort consists of 38 cases (patients with PCa and died of PCa within 10 years from diagnosis) and 91 controls (patients with PCa but alive 10 years after diagnosis). Gleason bioptic score, epithelial MMP expression and SERPINB5 methylation correlated with statistically significant increase in death risk OR. Compared with patients with high level of MMP, patients with low level of MMP had OR for specific death 4.78 times higher (p = 0.0066). After adjustment for age and Gleason score, none of the investigated biomarkers showed increased OR for PCa death. Our preliminary results suggest that evaluation, in prostate biopsy specimens, of a panel of biomarkers known to be involved in PCa progression is poorly indicative of tumor outcome.

  9. Immuno-histochemistry analysis of Helicobacter pylori antigen in renal biopsy specimens from patients with glomerulonephritis

    Directory of Open Access Journals (Sweden)

    Qian Li

    2013-01-01

    Full Text Available This study was conducted to investigate the relationship between Helicobacter pylori infection and three varieties of glomerulonephritis. Renal biopsy specimens from patients with Henoch Schonlein Purpura nephritis (HSPN; n = 10, membranous nephropathy (MN; n = 9 and lupus nephritis (LN; n = 27 were studied using immuno-histochemical labeling to clarify the etiological significance of H. pylori antigen in this disease. Immuno-histochemical labeling was performed using a mixture of anti-H. pylori-antibody-positive serum from nine volunteers; a mixture of anti-H. pylori-antibody-negative serum from nine volunteers was used as control. Staphylococci protein-A labeled by horseradish peroxidase was used as the second antibody in this study. A total of 34 of the 48 specimens revealed positive reaction with the anti-H. pylori-positive serum and five of the 48 specimens revealed positive reaction with the anti-H. pylori-negative serum. Positive reaction against anti-H. pylori-positive serum was seen in 10/10 patients with HSPN, six of nine patients with MN and 18/27 patients with LN. Statistical analysis showed that the difference of the positive reaction between anti-H. pylori-positive and negative sera was significant (χ 2 = 36.318, P = 0.000. Our study indicates that H. pylori infection may be associated with the development and/or progression of HSPN, MN and LN.

  10. Instant Transport Media for Biopsied Soft Tissue Specimens: A Comparative Study

    Directory of Open Access Journals (Sweden)

    Shankargouda Patil

    2015-01-01

    Full Text Available Background. Formalin, a traditionally preferred fixative in the field of pathology, has restricted usage in private settings. Since its toxicity violates the Occupational Safety and Health Administration regulations, an eco-friendly alternative would be the need of the hour. Hence an instant media which is economical and nontoxic and enables easy transport of biopsied soft tissue specimens in its original state is of vital importance. Materials and Methods. Commercially available fresh goat buccal mucosa specimens were sliced into smaller bits of equal dimensions and placed in six different containers containing 20% honey, 30% jaggery, milk, and ice for 1 hr, 6 hours, 12 hours, and 24 hours each with formalin as a positive control. After the set time interval, the specimens were fixed in 10% buffered formalin for 24 hours followed by routine processing and staining. The histologic interpretations were a blinded procedure and evaluated by two experts. Results were statistically analysed. Results. 30% jaggery proved to be an ideal transport media showing high quality preservation after 24 hours. 20% honey and ice showed optimal tissue preservation up to 6 hours following which quality deteriorated. Tissues transported in milk showed poor preservation. Conclusion. 30% jaggery can be endorsed in routine histopathological analysis as a transport media.

  11. Powered bone marrow biopsy procedures produce larger core specimens, with less pain, in less time than with standard manual devices

    Directory of Open Access Journals (Sweden)

    Larry J. Miller

    2011-07-01

    Full Text Available Bone marrow sampling remains essential in the evaluation of hematopoietic and many non-hematopoietic disorders. One common limitation to these procedures is the discomfort experienced by patients. To address whether a Powered biopsy system could reduce discomfort while providing equivalent or better results, we performed a randomized trial in adult volunteers. Twenty-six subjects underwent bilateral biopsies with each device. Core samples were obtained in 66.7% of Manual insertions; 100% of Powered insertions (P=0.002. Initial mean biopsy core lengths were 11.1±4.5 mm for the Manual device; 17.0±6.8 mm for the Powered device (P<0.005. Pathology assessment for the Manual device showed a mean length of 6.1±5.6 mm, width of 1.0±0.7 mm, and volume of 11.0±10.8 mm3. Powered device measurements were mean length of 15.3±6.1 mm, width of 2.0±0.3 mm, and volume of 49.1±21.5 mm3 (P<0.001. The mean time to core ejection was 86 seconds for Manual device; 47 seconds for the Powered device (P<0.001. The mean second look overall pain score was 33.3 for the Manual device; 20.9 for the Powered (P=0.039. We conclude that the Powered biopsy device produces superior sized specimens, with less overall pain, in less time.

  12. Evaluation of Ki67 expression across distinct categories of breast cancer specimens: a population-based study of matched surgical specimens, core needle biopsies and tissue microarrays.

    Directory of Open Access Journals (Sweden)

    Gøril Knutsvik

    Full Text Available Tumor cell proliferation in breast cancer is strongly prognostic and may also predict response to chemotherapy. However, there is no consensus on counting areas or cut-off values for patient stratification. Our aim was to assess the matched level of proliferation by Ki67 when using different tissue categories (whole sections, WS; core needle biopsies, CNB; tissue microarrays, TMA, and the corresponding prognostic value.We examined a retrospective, population-based series of breast cancer (n = 534 from the Norwegian Breast Cancer Screening Program. The percentage of Ki67 positive nuclei was evaluated by visual counting on WS (n = 534, CNB (n = 154 and TMA (n = 459.The median percentage of Ki67 expression was 18% on WS (hot-spot areas, 13% on CNB, and 7% on TMA, and this difference was statistically significant in paired cases. Increased Ki67 expression by all evaluation methods was associated with aggressive tumor features (large tumor diameter, high histologic grade, ER negativity and reduced patient survival.There is a significant difference in tumor cell proliferation by Ki67 across different sample categories. Ki67 is prognostic over a wide range of cut-off points and for different sample types, although Ki67 results derived from TMA sections are lower compared with those obtained using specimens from a clinical setting. Our findings indicate that specimen specific cut-off values should be applied for practical use.

  13. Evaluation of Ki67 expression across distinct categories of breast cancer specimens: a population-based study of matched surgical specimens, core needle biopsies and tissue microarrays.

    Science.gov (United States)

    Knutsvik, Gøril; Stefansson, Ingunn M; Aziz, Sura; Arnes, Jarle; Eide, Johan; Collett, Karin; Akslen, Lars A

    2014-01-01

    Tumor cell proliferation in breast cancer is strongly prognostic and may also predict response to chemotherapy. However, there is no consensus on counting areas or cut-off values for patient stratification. Our aim was to assess the matched level of proliferation by Ki67 when using different tissue categories (whole sections, WS; core needle biopsies, CNB; tissue microarrays, TMA), and the corresponding prognostic value. We examined a retrospective, population-based series of breast cancer (n = 534) from the Norwegian Breast Cancer Screening Program. The percentage of Ki67 positive nuclei was evaluated by visual counting on WS (n = 534), CNB (n = 154) and TMA (n = 459). The median percentage of Ki67 expression was 18% on WS (hot-spot areas), 13% on CNB, and 7% on TMA, and this difference was statistically significant in paired cases. Increased Ki67 expression by all evaluation methods was associated with aggressive tumor features (large tumor diameter, high histologic grade, ER negativity) and reduced patient survival. There is a significant difference in tumor cell proliferation by Ki67 across different sample categories. Ki67 is prognostic over a wide range of cut-off points and for different sample types, although Ki67 results derived from TMA sections are lower compared with those obtained using specimens from a clinical setting. Our findings indicate that specimen specific cut-off values should be applied for practical use.

  14. In vitro culture and characterization of enteric neural precursor cells from human gut biopsy specimens using polymer scaffold.

    Science.gov (United States)

    Krishnamohan, Janardhanam; Senthilnathan, Venugopal S; Vaikundaraman, Tirunelveli Muthiah; Srinivasan, Thangavelu; Balamurugan, Madasamy; Iwasaki, Masaru; Preethy, Senthilkumar; Abraham, Samuel Jk

    2013-08-01

    In vitro expansion and characterization of neural precursor cells from human gut biopsy specimens with or without Hirschsprung's disease using a novel thermoreversible gelation polymer (TGP) is reported aiming at a possible future treatment. Gut biopsy samples were obtained from five patients undergoing gut resection for Hirschsprung's disease (n = 1) or gastrointestinal disorders (n = 4). Cells isolated from the smooth muscle layer and the myenteric plexus were cultured in two groups for 18 to 28 days; Group I: conventional culture as earlier reported and Group II: using TGP scaffold. Neurosphere like bodies (NLBs) were observed in the cultures between 8th to 12th day and H & E staining was positive for neural cells in both groups including aganglionic gut portion from the Hirschsprung's disease patient. Immunohistochemistry using S-100 and neuron specific enolase (NSE) was positive in both groups but the TGP group (Group II) showed more number of cells with intense cytoplasmic granular positivity for both NSE and S-100 compared to Group I. TGP supports the in vitro expansion of human gut derived neuronal cells with seemingly better quality NLBs. Animal Studies can be tried to validate their functional outcome by transplanting the NLBs with TGP scaffolds to see whether this can enhance the outcome of cell based therapies for Hirschsprung's disease.

  15. The Diagnosis of Gastric Mucosa-associated Lymphoid Tissue Lymphoma by Flow Cytometry and Fluorescence in situ Hybridization of Biopsy Specimens.

    Science.gov (United States)

    Matsueda, Katsunori; Omote, Sizuma; Sakata, Masahiro; Fujita, Isao; Horii, Jouichiro; Toyokawa, Tatsuya

    2018-04-15

    Mucosa-associated lymphoid tissue (MALT) lymphoma and reactive inflammatory lymphoid changes are frequently difficult to distinguish based on a routine histological differential diagnosis. We were unable to diagnose gastric MALT lymphoma histologically using specimens obtained by endoscopy, although a flow cytometry (FCM) analysis demonstrated clonality of neoplastic cells by separating cells by CD45 gating. Furthermore, a fluorescence in situ hybridization (FISH) analysis showed trisomy 18. We therefore diagnosed gastric MALT lymphoma with trisomy 18. We recommend that FCM and FISH analyses of biopsy specimens be considered for diagnosing gastric MALT lymphoma if this diagnosis is suspected based on endoscopic findings.

  16. Diagnosis of Helicobacter pylori in gastric brush and biopsy specimens stained by Romanowsky and immunocytochemical methods: comparison with the CLOtest.

    Science.gov (United States)

    Faraker, C A

    1996-04-01

    Helicobacter pylori has been implicated in the pathogenesis of chronic gastritis, gastric and duodenal ulcer, and possibly gastric carcinoma. The organism may be detected by invasive or non-invasive methods with variable sensitivity. Paired gastric biopsy and gastric brush specimens were collected from 83 patients presenting with non-ulcer dyspepsia. One biopsy was tested for urease using the CLOtest, the other was processed to paraffin and consecutive sections were stained with haematoxylin and eosin, modified Giemsa and anti-H. pylori antisera. The brush specimens were stained with a rapid Romanowsky stain (Hema-Gurr) and anti-H. pylori. The CLOtest was positive in 31 cases, the Giemsa biopsy in 25, the anti-H. pylori biopsy in 27, the Hema-Gurr smear in 27 and the anti-H. pylori smear in 19. The sensitivities of the methods after omitting one inadequate biopsy were 96%, 93%, 100%, 96% and 78%, respectively. The specificities were 93% for the CLOtest and 100% for the other methods. While immunocytochemical staining of gastric biopsies may be the most sensitive method for H. pylori identification, the cost and turn around time of the technique may preclude its routine use. Gastric brush cytology is a highly sensitive and specific method for H. pylori detection that is quick and simple to perform. Its application is recommended for the routine diagnosis of H. pylori infection.

  17. Ga-68 DOTATOC PET/CT-Guided Biopsy and Cryoablation with Autoradiography of Biopsy Specimen for Treatment of Tumor-Induced Osteomalacia

    Energy Technology Data Exchange (ETDEWEB)

    Maybody, Majid, E-mail: maybodym@mskcc.org [Memorial Sloan Kettering Cancer Center, Interventional Radiology Service (United States); Grewal, Ravinder K. [Memorial Sloan Kettering Cancer Center, Molecular Imaging and Therapy Service, Department of Radiology (United States); Healey, John H. [Memorial Sloan Kettering Cancer Center, Orthopedic Surgical Oncology Service, Department of Surgery (United States); Antonescu, Cristina R. [Memorial Sloan Kettering Cancer Center, Department of Pathology (United States); Fanchon, Louise [Memorial Sloan Kettering Cancer Center, Department of Physics (United States); Hwang, Sinchun [Memorial Sloan Kettering Cancer Center, Department of Radiology (United States); Carrasquillo, Jorge A. [Memorial Sloan Kettering Cancer Center, Molecular Imaging and Therapy Service, Department of Radiology (United States); Kirov, Assen [Memorial Sloan Kettering Cancer Center, Department of Physics (United States); Farooki, Azeez [Memorial Sloan Kettering Cancer Center, Department of Medicine (United States)

    2016-09-15

    Tumor-induced osteomalacia (TIO) is a rare paraneoplastic syndrome caused by small benign tumors of mesenchymal origin also known as phosphaturic mesenchymal tumors mixed connective tissue variant. Excellent prognosis is expected with eradication of the culprit tumor. These small tumors are notoriously difficult to localize with conventional imaging studies; this often leads to an extensive work up and prolonged morbidity. We report a patient with clinical diagnosis of TIO whose culprit tumor was localized with Ga-68 DOTATOC PET/CT and MRI. Biopsy and cryoablation were performed under Ga-68 DOTATOC PET/CT guidance. Autoradiography of the biopsy specimen was performed and showed in situ correlation between Ga-68 DOTATOC uptake and histopathology with millimeter resolution.

  18. Rapid diagnosis of pleural tuberculosis by Xpert MTB/RIF assay using pleural biopsy and pleural fluid specimens

    OpenAIRE

    Du, Jinghui; Huang, Zikun; Luo, Qing; Xiong, Guoliang; Xu, Xiaomeng; Li, Weiting; Liu, Xu; Li, Junming

    2015-01-01

    Background: Early pleural tuberculosis (TB) diagnosis is particularly difficult. The aim of this study was to investigate the diagnostic accuracy of the Xpert MTB/RIF (Xpert) (Cepheid, Sunnyvale, CA) assay using pleural biopsy and pleural fluid specimens in patients with suspected pleural TB but who had a negative sputum acid-fast bacilli (AFB) smear. Materials and Methods: In this study, 134 sputum smear-negative suspected pleural TB patients were selected. Paired pleural fluid and pleural b...

  19. Biopsy

    Science.gov (United States)

    ... to examine tissue for disease. Normal Results The tissue removed is normal. What Abnormal Results Mean An abnormal biopsy means that the tissue or cells have an unusual structure, shape, size, ...

  20. Sequence Capture and Phylogenetic Utility of Genomic Ultraconserved Elements Obtained from Pinned Insect Specimens.

    Directory of Open Access Journals (Sweden)

    Bonnie B Blaimer

    Full Text Available Obtaining sequence data from historical museum specimens has been a growing research interest, invigorated by next-generation sequencing methods that allow inputs of highly degraded DNA. We applied a target enrichment and next-generation sequencing protocol to generate ultraconserved elements (UCEs from 51 large carpenter bee specimens (genus Xylocopa, representing 25 species with specimen ages ranging from 2-121 years. We measured the correlation between specimen age and DNA yield (pre- and post-library preparation DNA concentration and several UCE sequence capture statistics (raw read count, UCE reads on target, UCE mean contig length and UCE locus count with linear regression models. We performed piecewise regression to test for specific breakpoints in the relationship of specimen age and DNA yield and sequence capture variables. Additionally, we compared UCE data from newer and older specimens of the same species and reconstructed their phylogeny in order to confirm the validity of our data. We recovered 6-972 UCE loci from samples with pre-library DNA concentrations ranging from 0.06-9.8 ng/μL. All investigated DNA yield and sequence capture variables were significantly but only moderately negatively correlated with specimen age. Specimens of age 20 years or less had significantly higher pre- and post-library concentrations, UCE contig lengths, and locus counts compared to specimens older than 20 years. We found breakpoints in our data indicating a decrease of the initial detrimental effect of specimen age on pre- and post-library DNA concentration and UCE contig length starting around 21-39 years after preservation. Our phylogenetic results confirmed the integrity of our data, giving preliminary insights into relationships within Xylocopa. We consider the effect of additional factors not measured in this study on our age-related sequence capture results, such as DNA fragmentation and preservation method, and discuss the promise of the UCE

  1. Comparison of Core Needle Biopsy and Excision Specimens for the Accurate Evaluation of Breast Cancer Molecular Markers: a Report of 1003 Cases.

    Science.gov (United States)

    Chen, Jie; Wang, Zu; Lv, Qing; Du, Zhenggui; Tan, Qiuwen; Zhang, Di; Xiong, Bingjun; Zeng, Helin; Gou, Juxiang

    2017-10-01

    In this study, we compared the accuracy of marker evaluation in core needle biopsy (CNB) specimens versus excision specimens (ESs) from breast cancer patients. This retrospective study used data collected from the breast cancer database at the West China Hospital, China. Immunohistochemistry (IHC) results from CNB specimens and ESs were compared, using estrogen receptor (ER), progesterone receptor (PR), human epidermal growth factor receptor 2 (HER2), and Ki-67 as markers. Molecular subtyping and endocrine therapy usage correlations based on CNB samples and ESs were evaluated. The results obtained from CNB samples and ESs exhibited substantial agreement for the detection of ER (κ = 0.522), PR (κ = 0.441), and HER2 (κ = 0.451), and also influenced endocrine therapy usage. Fair and poor correlations were observed for Ki-67 staining and molecular subtyping (κ = 0.195), respectively. This disagreement might be attributable to a combination of heterogeneity and large tumor size. This study indicates that the discordance rate in molecular marker staining between CNB specimens and ESs is significant enough that results obtained with CNB specimens should be used cautiously or verified using ESs.

  2. The value of touch imprint cytology of prostate core needle biopsy specimens – Kuwait experience

    Directory of Open Access Journals (Sweden)

    S. Hussein

    2015-12-01

    Conclusions: The routine use of TIC complements CNB reports and helps to provide an immediate and reliable cytological diagnosis of prostate lesions. TIC and serial sectioning of CNB specimens significantly improve the diagnostic accuracy.

  3. Percutaneous computed tomography-guided core needle biopsy of soft tissue tumors: results and correlation with surgical specimen analysis

    Energy Technology Data Exchange (ETDEWEB)

    Chojniak, Rubens; Grigio, Henrique Ramos; Bitencourt, Almir Galvao Vieira; Pinto, Paula Nicole Vieira; Tyng, Chiang J.; Cunha, Isabela Werneck da; Aguiar Junior, Samuel; Lopes, Ademar, E-mail: chojniak@uol.com.br [Hospital A.C. Camargo, Sao Paulo, SP (Brazil)

    2012-09-15

    Objective: To evaluate the efficacy of percutaneous computed tomography (CT)-guided core needle biopsy of soft tissue tumors in obtaining appropriate samples for histological analysis, and compare its diagnosis with the results of the surgical pathology as available. Materials and Methods: The authors reviewed medical records, imaging and histological reports of 262 patients with soft-tissue tumors submitted to CT-guided core needle biopsy in an oncologic reference center between 2003 and 2009. Results: Appropriate samples were obtained in 215 (82.1%) out of the 262 patients. The most prevalent tumors were sarcomas (38.6%), metastatic carcinomas (28.8%), benign mesenchymal tumors (20.5%) and lymphomas (9.3%). Histological grading was feasible in 92.8% of sarcoma patients, with the majority of them (77.9%) being classified as high grade tumors. Out of the total sample, 116 patients (44.3%) underwent surgical excision and diagnosis confirmation. Core biopsy demonstrated 94.6% accuracy in the identification of sarcomas, with 96.4% sensitivity and 89.5% specificity. A significant intermethod agreement about histological grading was observed between core biopsy and surgical resection (p < 0.001; kappa = 0.75). Conclusion: CT-guided core needle biopsy demonstrated a high diagnostic accuracy in the evaluation of soft tissue tumors as well as in the histological grading of sarcomas, allowing an appropriate therapeutic planning (author)

  4. A Clinical and Pathological Analysis of 3722 Renal Biopsy Specimens from Adults with Primary Glomerular Disease in Shandong Province, China

    Directory of Open Access Journals (Sweden)

    Y-C Hu

    2014-09-01

    Full Text Available Objectives: To determine the pattern of disease in adults with primary glomerular diseases (PGD in the Shandong Province of China, to identify the clinical and renal pathology and to assess the relationship between these two factors. Methods: This was a retrospective analysis of renal biopsies performed during the period January 2008 to June 2013. All biopsy specimens were evaluated according to the clinical data available and standard histological methods; the results were analysed according to age and clinical findings. Results: A total of 3722 renal biopsies from adults with PGD were analysed. Nephrotic syndrome and nephritic syndrome were the two most common indications for biopsy among all PGD cases. The most common form of primary glomerulonephritis was due to immunoglobulin A (IgA nephropathy (37.72%, followed by membranous glomerulonephritis (27.57%, minimal change disease (16.42%, focal segmental glomerulosclerosis [FSGS] (8.79% and mesangioproliferative glomerulonephritis [Non IgA] (5.05%. The most common cause of nephrotic syndrome was membranous nephropathy (44.00%. Immunoglobulin A nephropathy was the leading cause of nephritic syndrome, asymptomatic urinary abnormalities and chronic renal failure. Crescentic glomerulonephritis was the pathological type associated with an older age group, whereas minimal change disease was the pathological type associated with a younger age group. Over the six years analysed, membranous glomerulonephritis showed a significant per cent increase, minimal change disease did not significantly vary and FSGS decreased slightly. Conclusions: Nephrotic syndrome was the most common indications for biopsy among all PGD cases. The most common form of primary glomerulonephritis was due to IgA nephropathy. Minimal change disease was the pathological type associated with a younger age group. Membranous nephropathy showed a significant per cent increase during the six years.

  5. The quality of specimens obtained by fine-needle aspiration biopsy ...

    African Journals Online (AJOL)

    Questionnaires were completed prior to the training session and after the subsequent six-month period, to determine the subjective assessment of the clinicians' perceived value of the training on their aspiration technique. Results: Five of the clinicians had never received training in FNAB technique. The adequacy of the ...

  6. The quality of specimens obtained by fine-needle aspiration biopsy ...

    African Journals Online (AJOL)

    2011-10-27

    Oct 27, 2011 ... He was born between 936 and 940 near Cordoba in Spain, and died in 1013. He discussed needle puncture ..... Wu M, Burstein DE. Fine needle aspiration. Cancer Invest. 2004;22(4):620-628. 5. Koss LG. Koss' diagnostic cytology and its histopathologic bases. 5th ed. Philadelphia: Lippincott, Williams and ...

  7. Comparison of diagnostic quality of kidney biopsy obtained using 16g and 18g needles in patients with diffuse renal disease

    Directory of Open Access Journals (Sweden)

    Komal Arora

    2012-01-01

    Full Text Available To determine the diagnostic quality and complication rates of 16G and 18G needles in biopsy of the kidney, we performed renal biopsy using a biopsy gun under ultrasound guidance in 50 patients who were prospectively and evenly assigned to one of the two needle biopsy methods from April 2007 until May 2008. Two cores of renal biopsy specimen were obtained in each case and subjected to histopathological and immunoflourescence (IF examination. Pain associated with the procedure was assessed using a visual analog scale. The number of glomeruli retrieved using the 16G needle ranged from 0 to 30 (mean 9.42 ± 5.5 and those retrieved using 18G needle ranged from 0 to 19 (mean 7.72 ± 4.4, P <0.05. The quality of biopsy was poorer with 18G needle as compared with 16G needles because of a higher amount of fragmentation and crushing artifact. There was no difference in the compli-cation rates between the two needles (2% each. The 16G needle was associated with significantly more pain than the 18G needle. We conclude that our study demonstrates the benefit of the larger 16G needle in providing more tissue and glomeruli, which is more diagnostically useful. However, the use of 16G needle was associated with significantly more pain than the 18G needle, and may be a better compromise for diagnostic usefulness and patient acceptability.

  8. Magnetic resonance imaging for prostate cancer: Comparative studies including radical prostatectomy specimens and template transperineal biopsy

    Directory of Open Access Journals (Sweden)

    Liam Toner

    2015-12-01

    Conclusions: mpMRI has an increasing role for PCa diagnosis, staging, and directing management toward improving patient outcomes. Its sensitivity and specificity when compared with RP and TTPB specimens are less than what some expect, possibly reflecting a learning curve for the technique of mpMRI.

  9. Significant association between renal function and amyloid-positive area in renal biopsy specimens in AL amyloidosis

    Directory of Open Access Journals (Sweden)

    Kuroda Takeshi

    2012-09-01

    Full Text Available Abstract Background The kidney is a major target organ for systemic amyloidosis that often affects the kidney including proteinura, and elevated serum creatinine (Cr. The correlation between amount of amyloid deposits and clinical parameters is not known. The aim of this study was to clarify correlation the amyloid area in all renal biopsy specimen and clinical parameters. Methods Fifty-eight patients with an established diagnosis of AL amyloidosis participated in the study. All patients showed amyloid deposits in renal biopsies. We retrospectively investigated the correlation between clinical data and amyloid occupied area in whole renal biopsy specimens. Results The area occupied by amyloid was less than 10% in 57 of the 58 patients, and was under 2% in 40. For statistical analyses, %amyloid-positive areas were transformed to common logarithmic values (Log10%amyloid. Cr showed significant correlation with Log10%amyloid and estimated glomerular filtration rate (eGFR showed the significant negative correlation. Patient age, cleatinine clearance (Ccr, blood urea nitorogen, and urinary protein was not significantly correlated with Log10%amyloid. The correlation with other clinical factors such as sex, and serum concentrations of total protein, albumin, immunoglobulins, compliments was evaluated. None of these factors significantly correlated with Log10%amyloid. According to sex- and age- adjusted multiple linear regression analysis, Log10%amyloid had significant positive association with Cr and significant negative association with eGFR. Conclusion There is significant association between amyloid-positive area in renal tissue and renal function, especially Cr and eGFR. The level of Cr and eGFR may be a marker of amount of amyloid in renal tissue.

  10. The need for using fluoroscopic guidance to obtain gastric biopsies when in search of Helicobacter pylori with a nonendoscopic method

    International Nuclear Information System (INIS)

    Bender, Greg N.; Mullins, Daniel J.; Makuch, Richard S.

    1999-01-01

    Purpose: Nonendoscopic, fluoroscopic biopsy of the gastric mucosa, following barium examination of the stomach, has gained attention with its ease of performance and cost savings potential over endoscopy. Endoscopic research concerning the efficacy of biopsy sites has revealed an increased sensitivity of antral biopsies over greater curvature biopsies for the detection of Helicobacter pylori. Fluoroscopically guided biopsies of the gastric mucosal are studied to determine whether such a difference between site sensitivity held true. If not, blind biopsy through a nasogastric tube, which traditionally samples only the greater curvature, might prove an even less expensive alternative. Materials and methods: Seventy-two patients underwent nonendoscopic, fluoroscopically guided, mucosal biopsy of both the gastric antrum and the greater curvature of the stomach. Pathologic reports from both sites, using each patient as their own control, are compared to assess site sensitivity in the diagnosis of H. pylori gastritis. Results: The sensitivity for the detection of H. pylori gastritis by antral biopsy is 89% whereas the sensitivity of greater curvature biopsy is 62%. The difference is considered clinically significant at P≤0.05. Conclusions: This study confirms the need for antral biopsies when desiring a nonendoscopic approach to gastric mucosal sampling, in order to obtain a reasonable yield of data in dyspeptic patients with H. pylori gastritis. Blind techniques cannot reliably reach the antrum. Fluoroscopy can, and remains a less expensive alternative to endoscopy

  11. The need for using fluoroscopic guidance to obtain gastric biopsies when in search of Helicobacter pylori with a nonendoscopic method

    Energy Technology Data Exchange (ETDEWEB)

    Bender, Greg N.; Mullins, Daniel J.; Makuch, Richard S

    1999-12-01

    Purpose: Nonendoscopic, fluoroscopic biopsy of the gastric mucosa, following barium examination of the stomach, has gained attention with its ease of performance and cost savings potential over endoscopy. Endoscopic research concerning the efficacy of biopsy sites has revealed an increased sensitivity of antral biopsies over greater curvature biopsies for the detection of Helicobacter pylori. Fluoroscopically guided biopsies of the gastric mucosal are studied to determine whether such a difference between site sensitivity held true. If not, blind biopsy through a nasogastric tube, which traditionally samples only the greater curvature, might prove an even less expensive alternative. Materials and methods: Seventy-two patients underwent nonendoscopic, fluoroscopically guided, mucosal biopsy of both the gastric antrum and the greater curvature of the stomach. Pathologic reports from both sites, using each patient as their own control, are compared to assess site sensitivity in the diagnosis of H. pylori gastritis. Results: The sensitivity for the detection of H. pylori gastritis by antral biopsy is 89% whereas the sensitivity of greater curvature biopsy is 62%. The difference is considered clinically significant at P{<=}0.05. Conclusions: This study confirms the need for antral biopsies when desiring a nonendoscopic approach to gastric mucosal sampling, in order to obtain a reasonable yield of data in dyspeptic patients with H. pylori gastritis. Blind techniques cannot reliably reach the antrum. Fluoroscopy can, and remains a less expensive alternative to endoscopy.

  12. Can direct immunofluorescence testing still be accurate if performed on biopsy specimens after brief inadvertent immersion in formalin?

    Science.gov (United States)

    Arbesman, Joshua; Grover, Raminder; Helm, Thomas N; Beutner, Ernst H

    2011-07-01

    Direct immunofluorescence is useful in the diagnosis of autoimmune, vesiculobullous, and connective tissue diseases. Michel medium is typically indicated for transport, but clinicians may inadvertently place samples into formalin. We set out to determine the amount of time that specimens can remain in 10% buffered formalin and still retain their diagnostic properties. Biopsy samples were examined from cases with established diagnoses of bullous pemphigoid (n = 12), dermatitis herpetiformis (n = 6), and pemphigus vulgaris (n = 6) and exposed to formalin for time points ranging from 2 minutes to 4 hours. We found that immunoreactants were detectable in the majority of samples when subjected to 2 minutes of formalin exposure. Dermatitis herpetiformis and pemphigoid samples retained immunogenicity for 10 minutes, whereas pemphigus showed reduced immunogenicity for all samples studied. A nonimmunologic nuclear fluorochroming pattern was noted in some of the specimens after formalin immersion. Sample size, only examining 3 disease processes, and samples already having been in Michel medium were the major limitations in the study. In direct immunofluorescence studies, formalin exposure to biopsy specimens causes two types of artifactual changes: (1) the shortest exposure (2 minutes) causes complete loss of diagnostic markers of pemphigus; and (2) prolonged exposure changes tissue to a form that allows fluorescein-labeled antibodies to give fluorochroming reactions of nuclei (which can be mistaken for in vivo antinuclear antibody reactions of lupus erythematosus). After time intervals of 10 minutes to 2 hours, direct immunofluorescence studies of proven cases of bullous pemphigoid and dermatitis herpetiformis retained variable levels of specific reactivity. Copyright © 2010 American Academy of Dermatology, Inc. Published by Mosby, Inc. All rights reserved.

  13. Clonality Analysis of Helicobacter pylori in Patients Isolated from Several Biopsy Specimens and Gastric Juice in a Japanese Urban Population by Random Amplified Polymorphic DNA Fingerprinting

    Directory of Open Access Journals (Sweden)

    Nariaki Toita

    2013-01-01

    Full Text Available Background. The number of Helicobacter pylori clones infecting a single host has been discussed in numerous reports. The number has been suggested to vary depending on the regions in the world. Aim. The purpose of this study was to examine the number of clones infecting a single host in a Japanese urban population. Materials and Methods. Thirty-one Japanese patients undergoing upper gastrointestinal endoscopy were enrolled in this study. H. pylori isolates (total 104 strains were obtained from biopsy specimens (antrum, corpus, and duodenum and gastric juice. Clonal diversity was examined by the random amplified polymorphic DNA (RAPD fingerprinting method. Results. The RAPD fingerprinting patterns of isolates from each patient were identical or very similar. And the isolates obtained from several patients with 5- to 9-year intervals showed identical or very similar RAPD patterns. Conclusion. Each Japanese individual of an urban population is predominantly infected with a single H. pylori clone.

  14. Fluorescence microscopy is superior to polarized microscopy for detecting amyloid deposits in Congo red-stained trephine bone marrow biopsy specimens.

    Science.gov (United States)

    Marcus, Alan; Sadimin, Evita; Richardson, Maurice; Goodell, Lauri; Fyfe, Billie

    2012-10-01

    The classic gold standard for detecting amyloid deposits is Congo red-stained bright field and polarized microscopy (CRPM). A prior study showed that Congo red fluorescence (CRF) microscopy had increased sensitivity compared with traditional CRPM when analyzing fat pad specimens. The purpose of the current study was to determine the sensitivity of CRF for evaluating Congo red-stained bone marrow biopsy specimens, and to compare these results with those of CRPM. We compared the CRPM and the CRF analyses of 33 trephine bone marrow biopsy specimens with clinical or morphologic suspicion of amyloid deposits. These results were verified against immunohistochemical staining with anti-amyloid P antibody. CRF achieved 100% sensitivity, and CRPM achieved 75% sensitivity. Both groups showed 100% specificity compared with amyloid P immunohistochemical staining. The results show that CRF is a sensitive method to analyze trephine bone marrow biopsy specimens for amyloid deposits.

  15. Residual stress analysis in near net-shape formed specimens obtained by thermal spraying

    International Nuclear Information System (INIS)

    Fogarassy, P.; Manescu, A.; Markocsan, N.; Rustichelli, F.

    2004-01-01

    Neutron and X-ray diffraction measurements were performed in near-net shape formed conical specimens of yttria partial stabilised zirconia in order to evaluate the level of residual stress induced by the manufacturing process. A preliminary finite element analysis was also carried out. The X-ray measurements were done in two directions: axial and tangential. A three direction measurement (including also radial direction) was performed using neutron diffraction. In this case three points through the thickness of the samples were considered. We obtained in all three analysed specimens (three different mandrel removing methods considered) compressive stresses in the axial direction, tensile in the tangential one and negligable stresses in the radial direction. The experimental results are in good agreement with those predicted by the finite element analysis

  16. Residual stress analysis in near net-shape formed specimens obtained by thermal spraying

    Science.gov (United States)

    Fogarassy, P.; Manescu, A.; Markocsan, N.; Rustichelli, F.

    2004-07-01

    Neutron and X-ray diffraction measurements were performed in near-net shape formed conical specimens of yttria partial stabilised zirconia in order to evaluate the level of residual stress induced by the manufacturing process. A preliminary finite element analysis was also carried out. The X-ray measurements were done in two directions: axial and tangential. A three direction measurement (including also radial direction) was performed using neutron diffraction. In this case three points through the thickness of the samples were considered. We obtained in all three analysed specimens (three different mandrel removing methods considered) compressive stresses in the axial direction, tensile in the tangential one and negligable stresses in the radial direction. The experimental results are in good agreement with those predicted by the finite element analysis.

  17. Fluorescence techniques for diagnosing intestinal microsporidiosis in stool, enteric fluid, and biopsy specimens from acquired immunodeficiency syndrome patients with chronic diarrhea.

    Science.gov (United States)

    Conteas, C N; Sowerby, T; Berlin, G W; Dahlan, F; Nguyen, A; Porschen, R; Donovan, J; LaRiviere, M; Orenstein, J M

    1996-09-01

    To evaluate three fluorescent chitin stains for detecting microsporidia spores in specimens from acquired immunodeficiency syndrome (AIDS) patients with chronic diarrhea. We compared the Fungifluor, Calcofluor White, and Fungiqual A fluorochrome stains for identifying Enterocytozoon bieneusi and Septata intestinalis spores in stool, intestinal fluid, biopsy imprints, and paraffin biopsy sections. The modified chromotrope trichrome stain was used as the standard light microscopic technique for stool and fluid specimens. Stained and unstained paraffin sections and fluid preparations were also evaluated. Multiple specimens from 50 consecutive symptomatic AIDS patients and archival material from known microsporidia-positive AIDS patients were analyzed. Spores of E bieneusi and S intestinalis fluoresce brightly with all three fluorochrome stains in all of the types of diagnostic specimens. Fluorescing debris and the much larger fungal forms were readily distinguished. Spores were equally well detected in unfixed and formalin-fixed stool specimens, but were not as well detected after sodium acetate-acetic acid, polyvinyl acetate, and ethanol fixation. Bouin's tissue fixative gave a higher background staining than formalin. Spores were readily detected in archival paraffin sections and stool preparations, even when the specimens had been stained previously. Repeat fluorochrome staining was possible. The methods also could detect extraintestinal parasites in paraffin sections. The three fluorescent chitin stains are sensitive and rapid methods for detecting microsporidia spores in stool, intestinal fluid, biopsy imprint, and tissue specimens, even from archived material.

  18. High Yield of Adult Oligodendrocyte Lineage Cells Obtained from Meningeal Biopsy

    Directory of Open Access Journals (Sweden)

    Sissi Dolci

    2017-10-01

    Full Text Available Oligodendrocyte loss can lead to cognitive and motor deficits. Current remyelinating therapeutic strategies imply either modulation of endogenous oligodendrocyte precursors or transplantation of in vitro expanded oligodendrocytes. Cell therapy, however, still lacks identification of an adequate source of oligodendrocyte present in adulthood and able to efficiently produce transplantable cells. Recently, a neural stem cell-like population has been identified in meninges. We developed a protocol to obtain high yield of oligodendrocyte lineage cells from one single biopsy of adult rat meningeal tissue. From 1 cm2 of adult rat spinal cord meninges, we efficiently expanded a homogenous culture of 10 millions of meningeal-derived oligodendrocyte lineage cells in a short period of time (approximately 4 weeks. Meningeal-derived oligodendrocyte lineage cells show typical mature oligodendrocyte morphology and express specific oligodendrocyte markers, such as galactosylceramidase and myelin basic protein. Moreover, when transplanted in a chemically demyelinated spinal cord model, meningeal-derived oligodendrocyte lineage cells display in vivo-remyelinating potential. This oligodendrocyte lineage cell population derives from an accessible and adult source, being therefore a promising candidate for autologous cell therapy of demyelinating diseases. In addition, the described method to differentiate meningeal-derived neural stem cells into oligodendrocyte lineage cells may represent a valid in vitro model to dissect oligodendrocyte differentiation and to screen for drugs capable to promote oligodendrocyte regeneration.

  19. Evaluation of endoscopically obtained duodenal biopsy samples from cats and dogs in an adapter-modified Ussing chamber

    Science.gov (United States)

    DeBiasio, John V.; Suchodolski, Jan S.; Newman, Shelley; Musch, Mark W.; Steiner, Jörg M.

    2014-01-01

    This study was conducted to evaluate an adapter-modified Ussing chamber for assessment of transport physiology in endoscopically obtained duodenal biopsies from healthy cats and dogs, as well as dogs with chronic enteropathies. 17 duodenal biopsies from five cats and 51 duodenal biopsies from 13 dogs were obtained. Samples were transferred into an adapter-modified Ussing chamber and sequentially exposed to various absorbagogues and secretagogues. Overall, 78.6% of duodenal samples obtained from cats responded to at least one compound. In duodenal biopsies obtained from dogs, the rate of overall response ranged from 87.5% (healthy individuals; n = 8), to 63.6% (animals exhibiting clinical signs of gastrointestinal disease and histopathological unremarkable duodenum; n = 15), and 32.1% (animals exhibiting clinical signs of gastrointestinal diseases and moderate to severe histopathological lesions; n = 28). Detailed information regarding the magnitude and duration of the response are provided. The adapter-modified Ussing chamber enables investigation of the absorptive and secretory capacity of endoscopically obtained duodenal biopsies from cats and dogs and has the potential to become a valuable research tool. The response of samples was correlated with histopathological findings. PMID:24378587

  20. Evaluation of diagnostic methods for the detection of Helicobacter pylori in gastric biopsy specimens of dyspeptic patients

    Directory of Open Access Journals (Sweden)

    Ivy Bastos Ramis

    2012-09-01

    Full Text Available Helicobacter pylori infects nearly 50% of the world's population. This microorganism is accepted as the most important agent of gastritis and as a risk factor for peptic ulcer disease and gastric adenocarcinoma. Currently many diagnostic methods exist for detecting H. pylori, however they all have limitations, thus it is recommend a combination of at least two methods. The aim of this study was to evaluate diagnostic methods, such as in-house urease test, culture and Polymerase Chain Reaction (PCR, for the detection of the H. pylori in gastric biopsy specimens of 144 dyspeptic patients, using as gold standard the association between histology and rapid urease test. According to the gold standard used in this study, 48 (33.3% patients were infected with H. pylori, while 96 (66.7% were classified as not infected. The in-house urease test and the PCR were the most sensitive methods (100%, followed by culture (85.4%. However, the in-house urease test and the culture were the most specific (100%, followed by PCR (75%. In conclusion, this study showed that, in comparison with the combination of histology and rapid urease test, the in-house urease test and the PCR presented 100% of sensitivity in the diagnosis of gastric infection by H. pylori, while the in-house urease test and the culture reached 100% of specificity. These finding suggest that the combination of two or more methods may improve the accuracy of the H. pylori detection.

  1. Low lactase activity in a small-bowel biopsy specimen : Should dietary lactose intake be restricted in children with small intestinal mucosal damage?

    NARCIS (Netherlands)

    Koetse, HA; Vonk, RJ; Gonera-de Jong, GBC; Priebe, MG; Antoine, JM; Stellaard, F; Sauer, PJJ

    Objective. Small intestinal mucosal damage can result in decreased lactase activity (LA). When LA is low in a small-bowel biopsy (SBB) specimen, a reduction of dietary lactose intake is usually advised. This is often done by reducing dietary dairy products, which also reduces the intake of calcium,

  2. Towards real-time metabolic profiling of a biopsy specimen during a surgical operation by 1H high resolution magic angle spinning nuclear magnetic resonance: a case report

    Directory of Open Access Journals (Sweden)

    Piotto Martial

    2012-01-01

    Full Text Available Abstract Introduction Providing information on cancerous tissue samples during a surgical operation can help surgeons delineate the limits of a tumoral invasion more reliably. Here, we describe the use of metabolic profiling of a colon biopsy specimen by high resolution magic angle spinning nuclear magnetic resonance spectroscopy to evaluate tumoral invasion during a simulated surgical operation. Case presentation Biopsy specimens (n = 9 originating from the excised right colon of a 66-year-old Caucasian women with an adenocarcinoma were automatically analyzed using a previously built statistical model. Conclusions Metabolic profiling results were in full agreement with those of a histopathological analysis. The time-response of the technique is sufficiently fast for it to be used effectively during a real operation (17 min/sample. Metabolic profiling has the potential to become a method to rapidly characterize cancerous biopsies in the operation theater.

  3. Endometrial aspiration biopsy: a non-invasive method of obtaining functional lymphoid progenitor cells and mature natural killer cells.

    LENUS (Irish Health Repository)

    McMenamin, Moya

    2012-09-01

    The aim of this study was to compare the efficacy of endometrial aspiration biopsy (EAB) with the more traditional dilatation and curettage (D&C) for the procurement of lymphoid progenitor cells and uterine natural killer (NK) populations in endometrial tissue. This prospective observational study conducted in a tertiary referral university hospital examined endometrium obtained from 32 women admitted for laparoscopic gynaecological procedures. Each participant had endometrium sampled using both EAB and D&C. Both methods were assessed as a source of uterine NK and lymphoid progenitor cells. Similar proportions of mature CD45+CD56+ NK cells (range 25.4-36.2%) and CD45+CD34+ lymphoid progenitors (range 1.2-2.0%) were found in tissue obtained using both EAB and D&C. These cells were adequate for flow cytometric analysis, magnetic bead separation and culture. Colony formation by the CD34+ population demonstrated maturational potential. Tissues obtained via endometrial biopsy and D&C are equivalent, by analysis of uterine NK and lymphoid progenitor cells. The aim of this study was to compare two methods of endometrial sampling - endometrial aspiration biopsy and traditional dilatation and curettage - for the procurement of haematopoietic stem cells and uterine natural killer (NK) populations in endometrial tissue. Thirty-two women who had gynaecological procedures in a tertiary referral hospital participated in this study and had endometrial tissue collected via both methods. Similar populations of mature NK cells and haematopoietic stem cells were found in tissue obtained using both endometrial aspiration biopsy and dilatation and curettage. Tissue obtained via endometrial aspiration biopsy was adequate for the culture and growth of haematopoietic stem cells. We conclude that tissue obtained via endometrial biopsy and dilatation and curettage is equivalent, by analysis of uterine NK and haematopoietic stem cells using flow cytometry. This has implications for further

  4. Diagnostic multiplex polymerase chain reaction assay for the identification of Pseudomonas aeruginosa from the skin biopsy specimens in burn wound infections and detection of antibiotic susceptibility

    International Nuclear Information System (INIS)

    Mashouf, Rasoul Y.; Farahani, Hadi S.; Zamani, A.

    2008-01-01

    Objective was to identify Pseudomonas aeruginosa (P. aeruginosa) from the skin biopsy specimens in burn wound infections by multiplex polymerase chain reaction (M-PCR) and detection of antimicrobial susceptibility of isolates from culture. We conducted the cross-sectional study in 140 patients with wound infections who admitted to referral burn center of Motahari, Tehran, Iran, during a 12-month period from 2005-2006. Skin biopsy specimens were aseptically taken from each patient, one for PCR and one for bacterial culture. A M-PCR test based on simultaneous amplification of 2 lipoprotein genes: oprI and oprL, was used to directly detect fluorescent pseudomonades and P. aeruginosa in skin biopsy specimens. The susceptibility of P. aeruginosa isolates to 16 antibiotics was determined using the disc diffusion method. Out of 140 biopsy specimens, M-PCR detected 66 (47.2%) isolates, while culture detected 57 (40.7%) isolates as P. aeruginosa. Positive results for both genes which observed only for P. aeruginosa, while only one gene, oprI, was amplified from other fluorescent pseudomonades (n=12) and all other bacterial tested (n=62) were negative by the amplification test. The most effective antibiotics against isolate of P. aeruginosa were cefepime (79%), azetreonam (76%), ticarcillin-clavulanic acid (68%), tobramycin (62%) and amikacin (61%). Multiplex PCR assay appears promising for the rapid and sensitive detection of P. aeruginosa from the burned skin biopsy specimens. Simultaneous amplification of 2 lipoprotein genes: oprI and oprL could detect P. aeruginosa and oprI gene only for other fluorescent pseudomonades. (author)

  5. Development of test specimens to obtain the transmission factors to attenuate photons of 0.511 MeV

    International Nuclear Information System (INIS)

    Costa, Jacó Júlio de Souza; Cardoso, Domingos D'Oliveira; Gavazza, Sérgio; Oliveira, Cláudio Luiz de; Morales, Rudnei Karam; Amorim, Aneuri Souza de; Balthar, Mario Cesar Viegas; Oliveira, Luciano Santa Rita

    2017-01-01

    For designing a shielding, it is necessary, mainly, to determine or have access to the following parameters: transmission factors of the material used and type of radiation to be shielded. Cylindrical test specimens with different thicknesses were developed for experimentally obtaining the material transmission factor for shielding calculation. The cylindrical test specimens were made considering the geometric characteristics of the detector, the ease of production and the energy of 0.511 MeV from the 18 F-FDG decay. A type of concrete widely used in Brazil was used in the preparation of the cylindrical test specimens. (author)

  6. Development of test specimens to obtain the transmission factors to attenuate photons of 0.511 MeV

    Science.gov (United States)

    Costa, J. J. S.; Cardoso, D. D.; Gavazza, S.; Oliveira, C. L.; Morales, R. K.; Amorim, A. S.; Balthar, M. C. V.; Oliveira, L. S. R.

    2018-03-01

    For designing a shielding, it is necessary, mainly, to determine or have access to the following parameters: transmission factors of the material used and type of radiation to be shielded. Cylindrical test specimens with different thicknesses were developed for experimentally obtaining the material transmission factor for shielding calculation. The cylindrical test specimens were made considering the geometric characteristics of the detector, the ease of production and the energy of 0.511 MeV from the 18F-FDG decay. A type of concrete widely used in Brazil was used in the preparation of the cylindrical test specimens.

  7. The 3DBiopsy Prostate Biopsy System: Preclinical Investigation of a Needle, Actuator, and Specimen Collection Device Allowing Sampling of Individualized Prostate Lengths Between 20 and 60 mm.

    Science.gov (United States)

    Stone, Nelson N; Mouraviev, Vladimir; Schechter, David; Lucia, M Scott; Smith, Elizabeth E; Arangua, Paul; Hoenemeyer, John; Rosa, Jim; Bawa, Rajan; Crawford, E David

    2017-09-01

    To increase the likelihood of detecting anterior cancers within the prostate and provide a specimen that spans the length of the gland. Newly designed 17- and 15-gauge (G) biopsy needles, a variable actuator, and an integrated pathology system intended for the longer cores were developed and tested for this purpose. Testing was performed comparing 2 common cannula tip grinds, a Vet-point (sharp tip) and a Menghini-point (atraumatic tip), and were tested against 18-G Bard Monopty in porcine kidney. A variable actuator was developed to fire the needle 20-60 mm and tested in cadaver prostates. The aggregate firings for 3 different shot lengths comparing the Vet- with the Menghini-tip cannulas demonstrated 91% vs 85.2% fill (length of specimen/length of core bed, P = .007). A 15-G trocar needle with the Vet-tip cannula also had the best performance, with an aggregate standard deviation of 6.4% across 3 firing ranges and a minimum to maximum specimen length of 81%-105% of potential fill. Cadaver testing with the Vet-tip needles in the actuator for the transrectal (17-G) and transperineal (15-G) biopsies demonstrated mean fills of 93.3% and 76.5%, respectively. The new transrectal ultrasound needle obtained a 2-fold increase in specimen length over the standard Bard device (P planning. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Temno biopsy needle

    International Nuclear Information System (INIS)

    Quinn, S.F.; Demlow, T.; Dunkley, B.

    1991-01-01

    This paper reports on the Temno needle which is spring-activated biopsy needle that is being marketed to radiologists as a needle that can obtain histologic cores. One hundred fifteen biopsy procedures were performed; biopsy sites included liver; retroperitoneum; lung, mediastinum, and pleura; musculoskeletal structures; thyroid; abdominal and pelvic masses; and pancreas. The needle sizes included 21-gauge, 18-gauge, 16-gauge, and 14-gauge needles. The biopsy procedures were diagnostic in 87.8D% of cases, and the average biopsy specimen measured 1.0-40.0 mm. The biopsy diagnoses included both malignant and benign processes. The Temno needle has a lightweight, nonattenuating handle that makes it especially useful for CT-guided procedures

  9. Fatigue behavior of notched steel specimens with nanocrystallized surface obtained by severe shot peening

    International Nuclear Information System (INIS)

    Bagherifard, S.; Fernandez-Pariente, I.; Ghelichi, R.; Guagliano, M.

    2013-01-01

    Highlights: ► Steel notched specimens are shot peened using different peening parameters. ► Shot peening with severe parameters results in surface nanocrystallization. ► Severe treatment affects a thick layer of material by compressive residual stresses. ► Severe treatment results in a very significant fatigue strength improvement. -- Abstract: Among severe plastic deformation methods that result in surface nanocrystallization, shot peening has proved to be a promising technique. Application of severe air blast shot peening results in surface nanocrystallization, affects a thick layer of material with high compressive residual stresses but at the same time produces rather high surface roughness. In this study notched specimens with a stress concentration factor common in many structural components have been subjected to severe shot peening process. The mentioned treatment uses peening parameters essentially different from conventional ones. Roughness and X-ray diffraction residual stress measurements as well as microscopy observations have been carried out on the treated specimens. Room temperature rotating bending fatigue tests are performed to evaluate the effect of the treatment on specimens’ fatigue strength. Fracture surfaces have been then observed by scanning electron microscopy. The results indicate a very significant fatigue strength improvement for severely shot peened specimens in spite of their very high surface roughness.

  10. Usefulness of automated biopsy guns in image-guided biopsy

    International Nuclear Information System (INIS)

    Lee, Jung Hyung; Rhee, Chang Soo; Lee, Sung Moon; Kim, Hong; Woo, Sung Ku; Suh, Soo Jhi

    1994-01-01

    To evaluate the usefulness of automated biopsy guns in image-guided biopsy of lung, liver, pancreas and other organs. Using automated biopsy devices, 160 biopsies of variable anatomic sites were performed: Biopsies were performed under ultrasonographic(US) guidance in 95 and computed tomographic (CT) guidance in 65. We retrospectively analyzed histologic results and complications. Specimens were adequate for histopathologic diagnosis in 143 of the 160 patients(89.4%)-Diagnostic tissue was obtained in 130 (81.3%), suggestive tissue obtained in 13(8.1%), and non-diagnostic tissue was obtained in 14(8.7%). Inadequate tissue was obtained in only 3(1.9%). There was no statistically significant difference between US-guided and CT-guided percutaneous biopsy. There was no occurrence of significant complication. We have experienced mild complications in only 5 patients-2 hematuria and 2 hematochezia in transrectal prostatic biopsy, and 1 minimal pneumothorax in CT-guided percutaneous lung biopsy. All of them were resolved spontaneously. The image-guided biopsy using the automated biopsy gun was a simple, safe and accurate method of obtaining adequate specimen for the histopathologic diagnosis

  11. The anterior cerebral artery: II. A computer model of its cortical branches estereotaxically obtained from anatomical specimens

    Directory of Open Access Journals (Sweden)

    Raul Marino Jr

    1979-12-01

    Full Text Available This article is a corrollary of a previously published anatomical study of the anterior cerebral artery. The authors propose a method to obtain a computer model of the anterior cerebral artery, based on a combined system of stereotaxic coordinates and a specially developed computer program. The graphic analysis, thus obtained, is projected on a model atlas brain and an ideal diagram of this anatomical structure is obtained. Forty anatomical specimens were used for this study.

  12. Analysis of histopathological pattern of kidney biopsy specimens in Kuwait: A single-center, five-year prospective study

    Directory of Open Access Journals (Sweden)

    Emad Abdallah

    2015-01-01

    Full Text Available Glomerulonephritis (GN varies in incidence in different geographical areas due to different socioeconomic conditions and ethnicity, genetic variability and environmental factors. Our study is aimed to determine the histopathological pattern of kidney biopsies in Kuwait over the preceding five years. In a prospective study, we analyzed the clinical and pathological data of 214 kidney biopsies that were performed during the period from November 2009 to November 2014 at the Al-Khezam Dialysis Center, Al-Adan Hospital, Kuwait. Kidney biopsies were performed percutaneously using an automated gun guided by ultrasound. The biopsy samples were processed for light microscopy and immunofluorescence. Electron microscopy was performed only in selected cases. Age, gender, serum creatinine, 24-h urinary protein, virology, immunology profiles, indication for renal biopsy and histopathological findings were recorded for analysis. Primary GN was reported in 46.7%, secondary GN was reported in 42.9% and tubulointerstitial disease was reported in 10.3% of the 214 kidney biopsies studied. Among primary GN, membranous GN (MGN was the most common lesion (12.1%, followed by immunoglobulin A nephropathy (IgAN, 11.7%, minimal change disease (9.8%, focal and segmental glomerulosclerosis (9.3%, membranoproliferative GN (1.9%, Alport′s syndrome (1.4% and fibrillary GN (0.46%. Among biopsies that showed secondary GN, lupus nephritis was the most common (11.7%, followed by hypertensive glomerulosclerosis (10.3%, crescentic GN (7.1%, diabetic nephropathy (3.3%, thrombotic microangiopathy (2.3%, amyloidosis (2.3%, post-infectious GN (1.4% and myeloma kidney (0.9%. Among biopsies that showed tubulointerstitial disease, acute interstitial nephritis was the most common lesion (6.1%, followed by chronic interstitial nephritis (2.8% and acute tubular necrosis (1.4%. Our study indicates that MGN was the most common primary GN, followed by IgAN, while lupus nephritis was the most

  13. Importance of prostate-specific antigen (PSA) as a predictive factor for concordance between the Gleason scores of prostate biopsies and RADICAL prostatectomy specimens.

    Science.gov (United States)

    Lima, Nelson Gianni de; Soares, Daniel de Freitas Gomes; Rhoden, Ernani Luis

    2013-06-01

    To evaluate the concordance between the Gleason scores of prostate biopsies and radical prostatectomy specimens, thereby highlighting the importance of the prostate-specific antigen (PSA) level as a predictive factor of concordance. We retrospectively analyzed 253 radical prostatectomy cases performed between 2006 and 2011. The patients were divided into 4 groups for the data analysis and dichotomized according to the preoperative PSA, PSA level was 9.3±4.9 ng/mL. The overall concordance between the Gleason scores was 52%. Patients presented preoperative PSA levels PSA levels PSA levels ≥10 ng/dL (61% x 23%, p=0.023), which resulted in 77% upgrading after surgery in those patients with PSA levels ≥10 ng/dl. The Gleason scores of needle prostate biopsies and those of the surgical specimens were concordant in approximately half of the global sample. The preoperative PSA level was a strong predictor of discrepancy and might improve the identification of those patients who tended to be upgraded after surgery, particularly in patients with Gleason scores of 3 + 3 in the prostate biopsy and preoperative PSA levels ≥10 ng/mL.

  14. The accuracy of colposcopic biopsy

    DEFF Research Database (Denmark)

    Stoler, Mark H; Vichnin, Michelle D; Ferenczy, Alex

    2011-01-01

    We evaluated the overall agreement between colposcopically directed biopsies and the definitive excisional specimens within the context of three clinical trials. A total of 737 women aged 16-45 who had a cervical biopsy taken within 6 months before their definitive therapy were included. Per......-protocol, colposcopists were to also obtain a representative cervical biopsy immediately before definitive therapy. Using adjudicated histological diagnoses, the initial biopsies and the same day biopsies were correlated with the surgically excised specimens. The overall agreement between the biopsies taken within 6...... months of definitive therapy, and the definitive therapy diagnoses was 42% (weighted kappa = 0.34) (95% CI: 0.29-0.39). The overall underestimation of cervical intraepithelial neoplasia grade 2/3 or adenocarcinoma in situ (CIN2-3/AIS) and CIN3/AIS was 26 and 42%, respectively. When allowing for one...

  15. Importance of prostate-specific antigen (PSA as a predictive factor for concordance between the Gleason scores of prostate biopsies and RADICAL prostatectomy specimens

    Directory of Open Access Journals (Sweden)

    Nelson Gianni de Lima

    2013-06-01

    Full Text Available OBJECTIVE: To evaluate the concordance between the Gleason scores of prostate biopsies and radical prostatectomy specimens, thereby highlighting the importance of the prostate-specific antigen (PSA level as a predictive factor of concordance. METHODS: We retrospectively analyzed 253 radical prostatectomy cases performed between 2006 and 2011. The patients were divided into 4 groups for the data analysis and dichotomized according to the preoperative PSA, <10 ng/mL and ≥10 ng/mL. A p-score <0.05 was considered significant. RESULTS: The average patient age was 63.3±7.8 years. The median PSA level was 9.3±4.9 ng/mL. The overall concordance between the Gleason scores was 52%. Patients presented preoperative PSA levels <10 ng/mL in 153 of 235 cases (65% and ≥10 ng/mL in 82 of 235 cases (35%. The Gleason scores were identical in 86 of 153 cases (56% in the <10 ng/mL group and 36 of 82 (44% cases in the ≥10 ng/mL group (p = 0.017. The biopsy underestimated the Gleason score in 45 (30% patients in the <10 ng/mL group and 38 (46% patients in the ≥10 ng/mL (p = 0.243. Specifically, the patients with Gleason 3 + 3 scores according to the biopsies demonstrated global concordance in 56 of 110 cases (51%. In this group, the patients with preoperative PSA levels <10 ng/dL had higher concordance than those with preoperative PSA levels ≥10 ng/dL (61% x 23%, p = 0.023, which resulted in 77% upgrading after surgery in those patients with PSA levels ≥10 ng/dl. CONCLUSION: The Gleason scores of needle prostate biopsies and those of the surgical specimens were concordant in approximately half of the global sample. The preoperative PSA level was a strong predictor of discrepancy and might improve the identification of those patients who tended to be upgraded after surgery, particularly in patients with Gleason scores of 3 + 3 in the prostate biopsy and preoperative PSA levels ≥10 ng/mL.

  16. An innovative method for obtaining consistent images and quantification of histochemically stained specimens.

    Science.gov (United States)

    Linden, Michael A; Sedgewick, Gerald J; Ericson, Marna

    2015-04-01

    Obtaining digital images of color brightfield microscopy is an important aspect of biomedical research and the clinical practice of diagnostic pathology. Although the field of digital pathology has had tremendous advances in whole-slide imaging systems, little effort has been directed toward standardizing color brightfield digital imaging to maintain image-to-image consistency and tonal linearity. Using a single camera and microscope to obtain digital images of three stains, we show that microscope and camera systems inherently produce image-to-image variation. Moreover, we demonstrate that post-processing with a widely used raster graphics editor software program does not completely correct for session-to-session inconsistency. We introduce a reliable method for creating consistent images with a hardware/software solution (ChromaCal™; Datacolor Inc., NJ) along with its features for creating color standardization, preserving linear tonal levels, providing automated white balancing and setting automated brightness to consistent levels. The resulting image consistency using this method will also streamline mean density and morphometry measurements, as images are easily segmented and single thresholds can be used. We suggest that this is a superior method for color brightfield imaging, which can be used for quantification and can be readily incorporated into workflows. © The Author(s) 2015.

  17. Analysis of parasitic diseases diagnosed by tissue biopsy specimens at KyungHee Medical Center (1984-2005) in Seoul, Korea.

    Science.gov (United States)

    Choi, Won-Hyung; Chu, Jong-Phil; Jiang, Meihua; Lee, Yun-Sik; Kim, Bum-Shik; Kim, Deog-Gon; Park, Yong-Koo

    2010-03-01

    We analyzed parasitic diseases diagnosed by tissue biopsy specimens at KyungHee Medical Center (KMC) from 1984 to 2005. The total number of parasite infection cases was 150 (0.07%) out of the total 211,859 biopsy specimens submitted for histopathological examinations. They consisted of 62 cysticercosis, 23 sparganosis, 16 paragonimiasis, 15 amebiasis, 11 anisakiasis, 11 clonorchiasis, 3 ascariasis, 2 scabies, 2 enterobiasis, 2 trichuriasis, 1 leishmaniasis, 1 taeniasis, and 1 thelaziasis. Out of 62 cysticercosis cases, 55 were detected in subcutaneous tissues or the central nerve system. Eighteen out of 23 sparganosis cases were involved in muscular and subcutaneous tissues. In most anisakiasis cases, the involved organ was the stomach. The lung and the pleura were the most common site of paragonimiasis. The incidence of parasitic diseases during the first 5 years (1984-1988) was the highest of all observed periods. After 1989, similar incidences were shown throughout the period. Whereas cysticercosis was diagnosed in 34 cases during 1984-1988, no case has been diagnosed since 2000. In the case of sparganosis, the chronological incidence was almost uniform throughout the period 1984-2005. Paragonimiasis showed a similar tendency to cysticercosis. In gender and age distribution of parasitic diseases, men showed higher incidence rates than females, and the age groups of the 40s or older indicated higher infection frequencies than other age groups. Therefore, these results are a significant report to appear the tendency of human parasitic disease diagnosed by tissue biopsy in association with parasitosis at KMC in Seoul.

  18. Clinical significance of methicillin-resistant coagulase-negative staphylococci obtained from sterile specimens.

    Science.gov (United States)

    Tashiro, Masato; Izumikawa, Koichi; Ashizawa, Nobuyuki; Narukawa, Munetoshi; Yamamoto, Yoshihiro

    2015-01-01

    Distinguishing true coagulase-negative staphylococci bacteremia from contamination remains a challenge. We conducted a retrospective analysis of 183 patients with methicillin-resistant coagulase-negative staphylococci (MR-CoNS)-positive and methicillin-resistant Staphylococcus aureus-positive cultures obtained from sterile sites such as blood, synovial fluid, ascitic fluid, and cerebrospinal fluid. Of the 209 MR-CoNS isolates, 83 (39.7%) were considered infection associated, and 126 (60.3%) were considered contamination. MR-CoNS isolates cultured from synovial fluid were more likely to be infection associated (P = 0.009). The median interval from insertion of a central venous catheter to onset of infection tended to be longer in MR-CoNS infection cases than in methicillin-resistant S. aureus infection cases (41 days versus 14 days, P = 0.055). In conclusion, our results suggest that the proportion of cases of true MR-CoNS infection may be higher than previously reported. Copyright © 2015 Elsevier Inc. All rights reserved.

  19. Next-generation sequencing for molecular diagnosis of lung adenocarcinoma specimens obtained by fine needle aspiration cytology

    Science.gov (United States)

    Qiu, Tian; Guo, Huiqin; Zhao, Huan; Wang, Luhua; Zhang, Zhihui

    2015-06-01

    Identification of multi-gene variations has led to the development of new targeted therapies in lung adenocarcinoma patients, and identification of an appropriate patient population with a reliable screening method is the key to the overall success of tumor targeted therapies. In this study, we used the Ion Torrent next-generation sequencing (NGS) technique to screen for mutations in 89 cases of lung adenocarcinoma metastatic lymph node specimens obtained by fine-needle aspiration cytology (FNAC). Of the 89 specimens, 30 (34%) were found to harbor epidermal growth factor receptor (EGFR) kinase domain mutations. Seven (8%) samples harbored KRAS mutations, and three (3%) samples had BRAF mutations involving exon 11 (G469A) and exon 15 (V600E). Eight (9%) samples harbored PIK3CA mutations. One (1%) sample had a HRAS G12C mutation. Thirty-two (36%) samples (36%) harbored TP53 mutations. Other genes including APC, ATM, MET, PTPN11, GNAS, HRAS, RB1, SMAD4 and STK11 were found each in one case. Our study has demonstrated that NGS using the Ion Torrent technology is a useful tool for gene mutation screening in lung adenocarcinoma metastatic lymph node specimens obtained by FNAC, and may promote the development of new targeted therapies in lung adenocarcinoma patients.

  20. Hypoxia-Inducible Factor-1α Expression in Kidney Transplant Biopsy Specimens After Reperfusion Is Associated With Early Recovery of Graft Function After Cadaveric Kidney Transplantation.

    Science.gov (United States)

    Oda, T; Ishimura, T; Yokoyama, N; Ogawa, S; Miyake, H; Fujisaw, M

    Ischemia/reperfusion injury during kidney transplantation (KTx) delays allograft recovery. Hypoxia-inducible factor-1α (HIF-1α) is the key regulator of the protective response to ischemia/reperfusion injury. We evaluated the impact of the HIF-1α signaling pathway on allograft recovery during cadaveric KTx. Between 1996 and 2015, 46 patients underwent cadaveric KTx. The expression levels of HIF-1α-related proteins, including phosphoinositide 3-kinase, phosphorylated (p)-Akt, p-mammalian target of rapamycin, p-Eukaryotic translation initiation factor 4E, p-S6 ribosomal protein, and HIF-1α, were immunohistochemically evaluated and semi-quantitatively scored in graft biopsy specimens after 1 hour of revascularization. Ten kidney biopsy specimens collected during donor nephrectomy for living KTx were used as controls. Delayed graft function (DGF) was defined as the need for dialysis within 1 week of KTx. We compared the staining scores of each protein and several clinical parameters between patients with and those without DGF. Expression levels of all six proteins in specimens after revasculization were elevated compared with those in controls. Thirty-five patients had DGF. Expression levels of PI3K, p-AKT, p-mTOR, p-eIF4E, and HIF-1α were significantly higher in patients without DGF than in those with DGF. Univariate analysis identified expression levels of p-Akt, p-S6, and HIF-1α, in addition to donor type (heart beating/non-heart beating), cold ischemic time, and donor age as significant predictors of DGF. Of these, only expression levels of HIF-1α and donor type were independently associated with DGF in multivariate analysis. Up-regulation of HIF-1α in allografts after reperfusion may be a predictor of early recovery after cadaveric KTx. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Comparison of HER2 and phospho-HER2 expression between biopsy and resected breast cancer specimens using a quantitative assessment method.

    Directory of Open Access Journals (Sweden)

    Yalai Bai

    Full Text Available BACKGROUND: HER2/Neu (ErbB-2 overexpression, which occurs in 15-20% of breast cancer cases, is associated with better response to treatment with the drug trastuzumab. PhosphoHER2 (pHER2 has been evaluated for prediction of response to trastuzumab. Both markers are heterogeneously detected and are potentially subject to loss as a consequence of delayed time to fixation. Here, we quantitatively assess both markers in core needle biopsies (CNBs and matched tumor resections to assess concordance between the core and the resection and between HER2 and pHER2. METHODS: A selected retrospective collection of archival breast cancer cases yielded 67 cases with both core and resection specimens. Both HER2 and pTyr(1248HER2 were analyzed by the AQUA® method of quantitative immunofluorescence on each specimen pair. RESULTS: Both HER2 immunoreactivity (P<0.0001 and pTyr(1248HER2 immunoreactivity (P<0.0001 were lower in resections relative to CNB specimens. However, clinical implications of this change may not be evident since no case changed from 3+ (CNB to negative (resection. Assessment of pTyr(1248HER2 showed no direct correlation with HER2 in either CNB or resection specimens. CONCLUSIONS: The data suggest that measurement of both HER2 and phospho- Tyr(1248HER2, in formalin-fixed tissue by immunological methods is significantly affected by pre-analytic variables. The current study warrants the adequate handling of resected specimens for the reproducible evaluation of HER2 and pHER2. The level of pTyr(1248HER2, was not correlated to total HER2 protein. Further studies are required to determine the significance of these observations with respect to response to HER2 directed therapies.

  2. Surveillance cultures of samples obtained from biopsy channels and automated endoscope reprocessors after high-level disinfection of gastrointestinal endoscopes

    Directory of Open Access Journals (Sweden)

    Chiu King-Wah

    2012-09-01

    Full Text Available Abstract Background The instrument channels of gastrointestinal (GI endoscopes may be heavily contaminated with bacteria even after high-level disinfection (HLD. The British Society of Gastroenterology guidelines emphasize the benefits of manually brushing endoscope channels and using automated endoscope reprocessors (AERs for disinfecting endoscopes. In this study, we aimed to assess the effectiveness of decontamination using reprocessors after HLD by comparing the cultured samples obtained from biopsy channels (BCs of GI endoscopes and the internal surfaces of AERs. Methods We conducted a 5-year prospective study. Every month random consecutive sampling was carried out after a complete reprocessing cycle; 420 rinse and swabs samples were collected from BCs and internal surface of AERs, respectively. Of the 420 rinse samples collected from the BC of the GI endoscopes, 300 were obtained from the BCs of gastroscopes and 120 from BCs of colonoscopes. Samples were collected by flushing the BCs with sterile distilled water, and swabbing the residual water from the AERs after reprocessing. These samples were cultured to detect the presence of aerobic and anaerobic bacteria and mycobacteria. Results The number of culture-positive samples obtained from BCs (13.6%, 57/420 was significantly higher than that obtained from AERs (1.7%, 7/420. In addition, the number of culture-positive samples obtained from the BCs of gastroscopes (10.7%, 32/300 and colonoscopes (20.8%, 25/120 were significantly higher than that obtained from AER reprocess to gastroscopes (2.0%, 6/300 and AER reprocess to colonoscopes (0.8%, 1/120. Conclusions Culturing rinse samples obtained from BCs provides a better indication of the effectiveness of the decontamination of GI endoscopes after HLD than culturing the swab samples obtained from the inner surfaces of AERs as the swab samples only indicate whether the AERs are free from microbial contamination or not.

  3. Comparison of pathological data between prostate biopsy and radical prostatectomy specimen in patients with low to very low risk prostate cancer.

    Science.gov (United States)

    Lendínez-Cano, G; Alonso-Flores, J; Beltrán-Aguilar, V; Cayuela, A; Salazar-Otero, S; Bachiller-Burgos, J

    2015-10-01

    To analyze the correlation between pathological data found in radical prostatectomy and previously performed biopsy in patients at low risk prostate cancer. A descriptive, cross-sectional study was conducted to assess the characteristics of radical prostatectomies performed in our center from January 2012 to November 2014. The inclusion criteria were patients with low-risk disease (cT1c-T2a, PSA≤10ng/mL and Gleason score≤6). We excluded patients who had fewer than 8 cores in the biopsy, an unspecified number of affected cores, rectal examinations not reported in the medical history or biopsies performed in another center. Of the 184 patients who underwent prostatectomy during this period, 87 met the inclusion criteria, and 26 of these had<3 affected cores and PSA density≤.15 (very low risk). In the entire sample, the percentage of undergrading (Gleason score≥7) and extracapsular invasion (pT3) was 18.4% (95% CI 10.3-27.6) and 10.35% (95% CI 4.6-17.2), respectively. The percentage of positive margins was 21.8% (95% CI 12.6-29.9). In the very low-risk group, we found no cases of extracapsular invasion and only 1 case of undergrading (Gleason 7 [3+4]), representing 3.8% of the total (95% CI 0-12.5). Predictors of no correlation (stage≥pT3a or undergrading) were the initial risk group, volume, PSA density and affected cores. Prostate volume, PSA density, the number of affected cores and the patient's initial risk group influence the poor pathological prognosis in the radical prostatectomy specimen (extracapsular invasion and Gleason score≥7). Copyright © 2014 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  4. Ultrasound-guided renal biopsy: experience using an automated core biopsy system.

    Science.gov (United States)

    Chan, R; Common, A A; Marcuzzi, D

    2000-04-01

    To assess the safety and efficacy of ultrasound-guided percutaneous renal biopsy using an automated core biopsy system, and to determine radiologists' accuracy in predicting sample adequacy. Ninety-five biopsies were performed on 25 native kidneys and 70 renal allografts using a 16-gauge automated, spring-loaded core biopsy device under real-time sonographic guidance. Radiologists performing the biopsy estimated the number of core samples needed to obtain an adequate specimen, based on visual inspection of each core. The final determination of the number of samples was made by a pathology technologist who attended each biopsy, based on preliminary microscopic examination of tissue cores. After each biopsy, an ultrasonographic examination was performed to search for biopsy-related hemorrhage, and a questionnaire was given to the patient to determine biopsy-related complications, which were categorized as either minor or major. The main indication for biopsy was acute renal failure (in 43.2% of biopsies). An average of 3 tissue cores per biopsy were obtained. Of the 94 patients in whom a biopsy was conducted to exclude diffuse renal disease, a mean of 12.5 glomeruli were present in each specimen. Overall, adequate tissue for diagnosis was obtained in 98.9% of cases. The radiologists' estimate of the number of core samples needed concurred with the pathology technologists' determination of sample adequacy in 88.4% of cases. A total of 26 complications occurred (in 27.4% of biopsies), consisting of 23 minor (24.2%) and 3 major (3.2%) complications. Real-time sonographic guidance in conjunction with an automated core biopsy system is a safe and accurate method of performing percutaneous renal biopsy. Routine use of sonographic examinations to search for biopsy-related complications is not indicated. Radiologists are accurate in estimating sample adequacy in most cases; however, the presence of a pathology technologist at the biopsy procedure virtually eliminates the

  5. Infective endocarditis with spondylodiscitis after prostate biopsy

    Directory of Open Access Journals (Sweden)

    Fernando Pivatto Júnior

    2014-04-01

    Full Text Available Transrectal ultrasonography-guided prostate needle biopsy is the ideal method to obtain prostate specimens for histological analysis and is therefore frequently used in clinical practice. In the majority of the studies, prostate biopsy is considered a safe procedure with few major complications. In the present report, we describe a case of endocarditis with spondylodiscitis, two very rare complications of prostate biopsy.

  6. Receptor binding sites for substance P in surgical specimens obtained from patients with ulcerative colitis and Crohn disease

    Energy Technology Data Exchange (ETDEWEB)

    Mantyh, C.R.; Gates, T.S.; Zimmerman, R.P.; Welton, M.L.; Passaro, E.P. Jr.; Vigna, S.R.; Maggio, J.E.; Kruger, L.; Mantyh, P.W.

    1988-05-01

    Several lines of evidence indicate that tachykinin neuropeptides (substance P (SP), substance K (SK), and neuromedin K (NK)) play a role in regulating the inflammatory and immune responses. To test this hypothesis in a human inflammatory disease, quantitative receptor autoradiography was used to examine possible abnormalities in tachykinin binding sites in surgical specimens from patients with inflammatory bowel disease. In all cases, specimens were processed for quantitative receptor autoradiography by using /sup 125/I-labeled Bolton-Hunter conjugates of NK, SK, and SP. In colon tissue obtained from ulcerative colitis and Crohn disease patients, very high concentrations of SP receptor binding sites are expressed by arterioles and venules located in the submucosa, muscalairs mucosa, external circular muscle, external longitudinal muscle, and serosa, in contrast to control patients. These results demonstrate that receptor binding sites for SP, but not SK or NK, are ectopically expressed in high concentrations by cells involved in mediating inflammatory and immune responses. These data suggest that SP may be involved in the pathophysiology of inflammatory bowel disease and might provide some insight into the interaction between the nervous system and the regulation of inflammation and the immune response in human inflammatory disease.

  7. Magnetic resonance metabolic profiling of breast cancer tissue obtained with core needle biopsy for predicting pathologic response to neoadjuvant chemotherapy.

    Directory of Open Access Journals (Sweden)

    Ji Soo Choi

    Full Text Available The purpose of this study was to determine whether metabolic profiling of core needle biopsy (CNB samples using high-resolution magic angle spinning (HR-MAS magnetic resonance spectroscopy (MRS could be used for predicting pathologic response to neoadjuvant chemotherapy (NAC in patients with locally advanced breast cancer. After institutional review board approval and informed consent were obtained, CNB tissue samples were collected from 37 malignant lesions in 37 patients before NAC treatment. The metabolic profiling of CNB samples were performed by HR-MAS MRS. Metabolic profiles were compared according to pathologic response to NAC using the Mann-Whitney test. Multivariate analysis was performed with orthogonal projections to latent structure-discriminant analysis (OPLS-DA. Various metabolites including choline-containing compounds were identified and quantified by HR-MAS MRS in all 37 breast cancer tissue samples obtained by CNB. In univariate analysis, the metabolite concentrations and metabolic ratios of CNB samples obtained with HR-MAS MRS were not significantly different between different pathologic response groups. However, there was a trend of lower levels of phosphocholine/creatine ratio and choline-containing metabolite concentrations in the pathologic complete response group compared to the non-pathologic complete response group. In multivariate analysis, the OPLS-DA models built with HR-MAS MR metabolic profiles showed visible discrimination between the pathologic response groups. This study showed OPLS-DA multivariate analysis using metabolic profiles of pretreatment CNB samples assessed by HR- MAS MRS may be used to predict pathologic response before NAC, although we did not identify the metabolite showing statistical significance in univariate analysis. Therefore, our preliminary results raise the necessity of further study on HR-MAS MR metabolic profiling of CNB samples for a large number of cancers.

  8. Liver Biopsies for Chronic Hepatitis C: Should Nonultrasound-Guided Biopsies Be Abandoned?

    Directory of Open Access Journals (Sweden)

    Jennifer A Flemming

    2009-01-01

    Full Text Available BACKGROUND/OBJECTIVE: Liver biopsy has been the gold standard for grading and staging chronic hepatitis C virus (HCV-mediated liver injury. Traditionally, this has been performed by trained practitioners using a nonimage-guided percutaneous technique at the bedside. Recent literature suggests an expanding role for radiologists in obtaining biopsies using an ultrasound (US-guided technique. The present study was undertaken study to determine if the two techniques produced liver biopsy specimens of similar quality and hypothesized that at our institution, non-US-guided percutaneous liver biopsies for HCV would be of higher quality than US-guided specimens.

  9. Digital dewaxing of Raman signals: discrimination between nevi and melanoma spectra obtained from paraffin-embedded skin biopsies.

    Science.gov (United States)

    Tfayli, Ali; Gobinet, Cyril; Vrabie, Valeriu; Huez, Regis; Manfait, Michel; Piot, Olivier

    2009-05-01

    Malignant melanoma (MM) is the most severe tumor affecting the skin and accounts for three quarters of all skin cancer deaths. Raman spectroscopy is a promising nondestructive tool that has been increasingly used for characterization of the molecular features of cancerous tissues. Different multivariate statistical analysis techniques are used in order to extract relevant information that can be considered as functional spectroscopic descriptors of a particular pathology. Paraffin embedding (waxing) is a highly efficient process used to conserve biopsies in tumor banks for several years. However, the use of non-dewaxed formalin-fixed paraffin-embedded tissues for Raman spectroscopic investigations remains very restricted, limiting the development of the technique as a routine analytical tool for biomedical purposes. This is due to the highly intense signal of paraffin, which masks important vibrations of the biological tissues. In addition to being time consuming and chemical intensive, chemical dewaxing methods are not efficient and they leave traces of the paraffin in tissues, which affects the Raman signal. In the present study, we use independent component analysis (ICA) on Raman spectral images collected on melanoma and nevus samples. The sources obtained from these images are then used to eliminate, using non-negativity constrained least squares (NCLS), the paraffin contribution from each individual spectrum of the spectral images of nevi and melanomas. Corrected spectra of both types of lesion are then compared and classified into dendrograms using hierarchical cluster analysis (HCA).

  10. Constructing kinetics fatigue diagrams using testing results obtained on a machine with rigid loading for specimens of various thickness

    International Nuclear Information System (INIS)

    Simin'kovich, V.N.; Gladkij, Ya.N.; Deev, N.A.

    1981-01-01

    Bending tests of 40KhS steel specimens, tempered at 200 and 500 deg C, are conducted to investigate the possible effects of specimen thickness on fatigue crack growth. Kinetic fatigue diagrams are constructed using the investigation results. An increase in crack growth with thickness is observed only in high-tempered specimens. Changes in specimen thickness do not affect crack growth in 40KhS low-tempered steel [ru

  11. Equine preantral follicles obtained via the Biopsy Pick-Up method: histological evaluation and validation of a mechanical isolation technique.

    Science.gov (United States)

    Haag, K T; Magalhães-Padilha, D M; Fonseca, G R; Wischral, A; Gastal, M O; King, S S; Jones, K L; Figueiredo, J R; Gastal, E L

    2013-03-15

    The aims of this study in mares were to: (1) compare preantral follicle parameters between in vitro Biopsy Pick-Up (BPU) and scalpel blade collection methods and between histological and mechanical isolation processing (experiment 1); (2) histologically evaluate preantral follicles (experiment 2); and (3) compare histological analysis with a previously established mechanical isolation technique using a tissue chopper (experiment 3) for ovarian cortical fragments obtained in vivo using a BPU instrument. In experiment 1, preantral follicles were analyzed (N = 220; 90% primordial and 10% primary). Proportions of primordial and primary follicles did not differ (P > 0.05) between tissue collection (BPU vs. scalpel blade dissection) or processing (mechanical isolation vs. histology) methods. Follicle viability and morphology rates were similar (P > 0.05) between tissue collection methods, but mechanical isolation produced more (P histology. For experiment 2, preantral follicles (N = 332) were analyzed and primordial and transitional (combined) follicles and oocytes were 36.3 ± 0.3 and 26.1 ± 0.3 μm in diameter, respectively, and primary follicles and oocytes averaged 42.9 ± 1.8 and 31.8 ± 2.1 μm. For experiment 3 (188 preantral follicles), within the same animals, the proportion of primordial versus primary follicles was higher (P histological analysis (98%) compared to tissue chopper analysis (94%), and number of follicles per mg of tissue was not affected (P > 0.05) by processing methods. In conclusion, most parameters evaluated for preantral follicles were similar between histological and tissue chopper processing techniques; hence, mechanical isolation efficiently dissociated equine preantral follicles from the ovarian cortex. Therefore, the tissue chopper could be used to isolate large numbers of morphologically normal equine preantral follicles for cryopreservation and/or in vitro culture. Copyright © 2013 Elsevier Inc. All rights reserved.

  12. Muscle biopsy.

    Science.gov (United States)

    Meola, G; Bugiardini, E; Cardani, R

    2012-04-01

    Muscle biopsy is required to provide a definitive diagnosis in many neuromuscular disorders. It can be performed through an open or needle technique under local anesthesia. The major limitations of the needle biopsy technique are the sample size, which is smaller than that obtained with open biopsy, and the impossibility of direct visualization of the sampling site. However, needle biopsy is a less invasive procedure than open biopsy and is particularly indicated for diagnosis of neuromuscular disease in infancy and childhood. The biopsied muscle should be one affected by the disease but not be too weak or too atrophic. Usually, in case of proximal muscle involvement, the quadriceps and the biceps are biopsied, while under suspicion of mitochondrial disorder, the deltoid is preferred. The samples must be immediately frozen or fixed after excision to prevent loss of enzymatic reactivity, DNA depletion or RNA degradation. A battery of stainings is performed on muscle sections from every frozen muscle biopsy arriving in the pathology laboratory. Histological, histochemical, and histoenzymatic stainings are performed to evaluate fiber atrophy, morphological, and structural changes and metabolic disorders. Moreover, immunohistochemistry and Western blotting analysis may be used for expression analysis of muscle proteins to obtain a specific diagnosis. There are myopathies that do not need muscle biopsy since a genetic test performed on a blood sample is enough for definitive diagnosis. Muscle biopsy is a useful technique which can make an enormous contribution in the field of neuromuscular disorders but should be considered and interpreted together with the patient's family and clinical history.

  13. Comparison of urine and bladder or urethral mucosal biopsy culture obtained by transurethral cystoscopy in dogs with chronic lower urinary tract disease: 41 cases (2002 to 2011).

    Science.gov (United States)

    Sycamore, K F; Poorbaugh, V R; Pullin, S S; Ward, C R

    2014-07-01

    To compare aerobic bacterial culture of urine to cystoscopically obtained mucosal biopsies of the lower urinary tract in dogs. Retrospective review of case records from dogs that had transurethral cystoscopy at a veterinary teaching hospital between 2002 and 2011. Dogs that had culture results from cystocentesis obtained urine and transurethral cystoscopically obtained mucosal samples were included in the study. Pathogens identified were compared between sampling methods. Forty dogs underwent transurethral cystoscopy for lower urinary tract disease on 41 occasions. There was significant (P = 0 · 0003) agreement between urine and mucosal biopsy cultures. Both cultures were negative in 66% and positive in 17% of dogs. There was a 17% disagreement between the sampling methods. Although not statistically significant, more mucosal samples than urine cultures were positive for Escherichia coli. There was a good agreement between pathogen identification from urine and lower urinary tract mucosal cultures. These results do not support the utilisation of transurethral cystoscopy to obtain biopsy samples for culture in dogs with urinary tract infection and positive urine culture. Individual cases with possible chronic urinary tract infection and negative urine culture may benefit from transurethral cystoscopy to obtain biopsies for culture. © 2014 British Small Animal Veterinary Association.

  14. Comparação entre fragmentos obtidos com agulhas de calibres 14 e 12 em "core biopsy" estereotáxica de lesões mamárias impalpáveis: diferenças entre o tamanho dos fragmentos e freqüência dos tipos de lesões diagnosticadas Comparison between the fragments obtained by stereotactic core biopsy of nonpalpable breast lesions using 14- and 12-gauge needles: differences on the length of the fragments obtained and on the frequency of the types of diagnosed lesions

    Directory of Open Access Journals (Sweden)

    Maria do Carmo Abreu-e-Lima

    2001-10-01

    Full Text Available Com o objetivo de avaliar o desempenho das agulhas de calibres 14 e 12 na obtenção de "core biopsies" da mama sob controle estereotáxico, os autores compararam biópsias de lesões mamárias impalpáveis obtidas com agulhas desses calibres quanto ao tamanho dos fragmentos e freqüência dos tipos de lesões diagnosticadas. De um total de 1.009 biópsias, os autores analisaram 900 obtidas por agulhas 14 e 109 obtidas por agulhas 12, para análise da freqüência das lesões. Os tamanhos dos fragmentos foram analisados nos 700 primeiros casos para os espécimes obtidos por agulhas 14. A utilização de agulhas 12 resultou em maior tamanho dos fragmentos (p The purpose of this study was to compare the performance of 14- and 12-gauge needles for obtaining biopsy specimens under stereotactic guidance. The authors compared the biopsies of nonpalpable breast lesions using these different size needles, regarding the length of the fragments obtained and the types of diagnosed lesions. A total of 1,009 samples were obtained using 14-gauge (900 samples and 12-gauge (109 samples needles. The size of the samples was evaluated on the first 700 consecutive biopsies using 14-gauge needles. The use of 12-gauge needles consistently provided larger size specimens than 14-gauge needles (p < 0.001; a reduction in the prevalence of benign nonneoplastic lesions (p = 0.03 and a higher frequency of in situ and invasive carcinomas (p < 0.001 were also observed. These findings may suggest a higher diagnostic accuracy of biopsies performed with 12-gauge needles due to the larger samples obtained and/or due to a better radiological selection of those lesions, which were detected by digital mammography and biopsied under digital stereotactic guidance.

  15. COX-2 expression in papillary thyroid carcinoma (PTC in cytological material obtained by fine needle aspiration biopsy (FNAB

    Directory of Open Access Journals (Sweden)

    Krawczyk-Rusiecka Kinga

    2011-01-01

    Full Text Available Abstract Background COX-2 is an enzyme isoform that catalyses the formation of prostanoids from arachidonic acid. An increased COX-2 gene expression is believed to participate in carcinogenesis. Recent studies have shown that COX-2 up-regulation is associated with the development of numerous neoplasms, including skin, colorectal, breast, lung, stomach, pancreas and liver cancers. COX-2 products stimulate endothelial cell proliferation and their overexpression has been demonstrated to be involved in the mechanism of decreased resistance to apoptosis. Suppressed angiogenesis was found in experimental animal studies as a consequence of null mutation of COX-2 gene in mice. Despite the role of COX-2 expression remains a subject of numerous studies, its participation in carcinogenesis or the thyroid cancer progression remains unclear. Methods Twenty three (23 patients with cytological diagnosis of PTC were evaluated. After FNAB examination, the needle was washed out with a lysis buffer and the obtained material was used for COX-2 expression estimation. Total RNA was isolated (RNeasy Micro Kit, and RT reactions were performed. β-actin was used as endogenous control. Relative COX-2 expression was assessed in real-time PCR reactions by an ABI PRISM 7500 Sequence Detection System, using the ΔΔCT method. Results COX-2 gene expression was higher in patients with PTC, when compared to specimens from patients with non-toxic nodular goitre (NTG. Conclusions The preliminary results may indicate COX-2 role in thyroid cancer pathogenesis, however the observed variability in results among particular subjects requires additional clinical data and tumor progression analysis.

  16. Improved transvenous liver biopsy needle

    DEFF Research Database (Denmark)

    Henriksen, Jens Henrik Sahl; Matzen, P; Christoffersen, P

    1979-01-01

    A modified type of the standard transvenous cholangiography biopsy needle is described. The modified tranvenous liver biopsy needle caused only minimal artefactual changes of the liver biopsy specimens. The new type of biopsy needle is a modified Menghini needle. The conventional Menghini needle...... should be avoided for transvenous catheter biopsies because of risk of leaving catheter fragments in the liver....

  17. Diagnosis of multiple myeloma on based the material obtained by fine needle aspiration biopsy of the lungs

    Directory of Open Access Journals (Sweden)

    Bokun Radojka

    2004-01-01

    Full Text Available The patient presented in this paper was admitted to the hospital for the evaluation of radiologically revealed shadow in both lungs. In the course of diagnostic procedures, fine needle aspiration biopsy of the intrathoracic mass was performed. Cytologic analysis of the smear was performed because of clinical suspicion of plasma cell proliferative disease that was confirmed by bone marrow aspiration. Thus, the cytologic finding of intrathoracic lesion preceded the diagnosis of multiple myeloma.

  18. Evaluation of an endoscopic liver biopsy technique in green iguanas.

    Science.gov (United States)

    Hernandez-Divers, Stephen J; Stahl, Scott J; McBride, Michael; Stedman, Nancy L

    2007-06-15

    To establish a safe and effective endoscopic technique for collection of liver biopsy specimens from lizards by use of a 2.7-mm rigid endoscope system that is commonly available in zoologic veterinary practice. Prospective study. 11 subadult male green iguanas (Iguana iguana). Each lizard was anesthetized, and right-sided coelioscopic examination of the right liver lobe and gallbladder was performed. Three liver biopsy specimens were collected from each lizard by use of a 2.7-mm rigid endoscope and 1.7-mm (5-F) biopsy forceps. Biopsy samples were evaluated histologically for quality and crush artifact. Ten days following surgery, all iguanas were euthanatized and underwent full necropsy examination. For all 11 iguanas, the right liver lobe and gallbladder were successfully examined endoscopically, and 3 biopsy specimens of the liver were collected without complications. Mean +/- SD durations of anesthesia and surgery were 24 +/- 7 minutes and 6.8 +/- 1.0 minutes, respectively. At necropsy, there was no evidence of trauma or disease associated with the skin or muscle entry sites, liver, or any visceral structures in any iguana. All 33 biopsy specimens were considered acceptable for histologic interpretation; in most samples, the extent of crush artifact was considered minimal. By use of a 2.7-mm rigid endoscope, liver biopsy procedures can be performed safely, swiftly, and easily in green iguanas. Biopsy specimens obtained by this technique are suitable for histologic examination. For evaluation of the liver and biopsy specimen collection in lizards, endoscopy is recommended.

  19. Significant association between renal function and area of amyloid deposition in kidney biopsy specimens in both AA amyloidosis associated with rheumatoid arthritis and AL amyloidosis.

    Science.gov (United States)

    Kuroda, Takeshi; Tanabe, Naohito; Hasegawa, Eriko; Wakamatsu, Ayako; Nozawa, Yukiko; Sato, Hiroe; Nakatsue, Takeshi; Wada, Yoko; Ito, Yumi; Imai, Naofumi; Ueno, Mitsuhiro; Nakano, Masaaki; Narita, Ichiei

    2017-06-01

    The kidney is a major target organ for systemic amyloidosis, which results in proteinuria and an elevated serum creatinine level. The clinical manifestations and precursor proteins of amyloid A (AA) and light-chain (AL) amyloidosis are different, and the renal damage due to amyloid deposition also seems to differ. The purpose of this study was to clarify haw the difference in clinical features between AA and AL amyloidosis are explained by the difference in the amount and distribution of amyloid deposition in the renal tissues. A total of 119 patients participated: 58 patients with an established diagnosis of AA amyloidosis (AA group) and 61 with AL amyloidosis (AL group). We retrospectively investigated the correlation between clinical data, pathological manifestations, and the area occupied by amyloid in renal biopsy specimens. In most of the renal specimens the percentage area occupied by amyloid was less than 10%. For statistical analyses, the percentage area of amyloid deposition was transformed to a common logarithmic value (Log 10 %amyloid). The results of sex-, age-, and Log 10 %amyloid-adjusted analyses showed that systolic blood pressure (SBP) was higher in the AA group. In terms of renal function parameters, serum creatinine, creatinine clearance (Ccr) and estimated glomerular filtration rate (eGFR) indicated significant renal impairment in the AA group, whereas urinary protein indicated significant renal impairment in the AL group. Pathological examinations revealed amyloid was predominantly deposited at glomerular basement membrane (GBM) and easily transferred to the mesangial area in the AA group, and it was predominantly deposited at in the AL group. The degree of amyloid deposition in the glomerular capillary was significantly more severe in AL group. The frequency of amyloid deposits in extraglomerular mesangium was not significantly different between the two groups, but in AA group, the degree amyloid deposition was significantly more severe, and

  20. Bone lesion biopsy

    Science.gov (United States)

    Bone biopsy; Biopsy - bone ... the cut, then pushed and twisted into the bone. Once the sample is obtained, the needle is ... sample is sent to a lab for examination. Bone biopsy may also be done under general anesthesia ...

  1. Detection of hepatitis C viral RNA sequences in fresh and paraffin-embedded liver biopsy specimens of non-A, non-B hepatitis patients

    NARCIS (Netherlands)

    Bresters, D.; Cuypers, H. T.; Reesink, H. W.; Chamuleau, R. A.; Schipper, M. E.; Boeser-Nunnink, B. D.; Lelie, P. N.; Jansen, P. L.

    1992-01-01

    In this study methods of HCV-RNA detection in fresh frozen and formalin-fixed, paraffin-embedded liver biopsies are described. Of 22 untreated chronic non-A, non-B hepatitis patients and 6 control patients, a plasma sample and part of a liver biopsy were freshly frozen for hepatitis C virus (HCV)

  2. Mononuclear cell infiltration and its relation to the expression of major histocompatibility complex antigens and adhesion molecules in pancreas biopsy specimens from newly diagnosed insulin-dependent diabetes mellitus patients.

    OpenAIRE

    Itoh, N; Hanafusa, T; Miyazaki, A; Miyagawa, J; Yamagata, K; Yamamoto, K; Waguri, M; Imagawa, A; Tamura, S; Inada, M

    1993-01-01

    We examined pancreas biopsy specimens from 18 newly diagnosed insulin-dependent diabetes mellitus (IDDM) patients to elucidate the mechanism underlying beta cell destruction. Pancreas islets were seen in all patients and insulitis in eight patients. Infiltrating mononuclear cells consisted of CD4+T, CD8+T, B lymphocytes, and macrophages. Among them, CD8+T lymphocytes were predominant and macrophages followed. The expression of MHC class I antigens was increased in islet and endothelial cells ...

  3. A comparison of ARMS and mutation specific IHC for common activating EGFR mutations analysis in small biopsy and cytology specimens of advanced non small cell lung cancer

    OpenAIRE

    Wang, Xueqing; Wang, Guoqing; Hao, Yueyue; Xu, Yinhong; Zhang, Lihua

    2014-01-01

    We have compared mutation analysis by Amplification Refractory Mutation System (ARMS) and epidermal growth factor receptor (EGFR) mutant-specific antibodies for their ability to detect two common activating EGFR mutations in a cohort of 115 advanced non-small cell lung cancer (NSCLC), including cytology material, core biopsy, and bronchoscopic biopsies. Assessment of EGFR mutation status was performed by using antibodies and ARMS assay specific to the two major forms of mutant EGFR, exon 19 d...

  4. Predictive factors for invasive cancer in surgical specimens following an initial diagnosis of ductal carcinoma in situ after stereotactic vacuum-assisted breast biopsy in microcalcification-only lesions.

    Science.gov (United States)

    Gümüş, Hatice; Mills, Philippa; Fish, David; Gümüş, Metehan; Cox, Karina; Devalia, Haresh; Jones, Sue; Jones, Peter; Sever, Ali R

    2016-01-01

    The aim of this study was to determine the incidence of invasive breast carcinoma in patients with preoperative diagnosis of ductal carcinoma in situ (DCIS) by stereotactic vacuum-assisted biopsy (SVAB) performed for microcalcification-only lesions, and to identify the predictive factors of invasion. From 2000 to 2010, the records of 353 DCIS patients presenting with microcalcification-only lesions who underwent SVAB were retrospectively reviewed. The mammographic size of microcalcification cluster, presence of microinvasion within the cores, the total number of calcium specks, and the number of calcium specks within the retrieved core biopsy specimen were recorded. Patients were grouped as those with or without invasion in the final pathologic report, and variables were compared between the two groups. The median age was 58 years (range, 34-88 years). At histopathologic examination of the surgical specimen, 63 of 353 patients (17.8%) were found to have an invasive component, although SVAB cores had only shown DCIS preoperatively. The rate of underestimation was significantly higher in patients with microcalcification covering an area of 40 mm or more, in the presence of microinvasion at biopsy, and in cases where less than 40% of the calcium specks were removed from the lesion. Invasion might be underestimated in DCIS cases diagnosed with SVAB performed for microcalcification-only lesions, especially when the mammographic size of calcification is equal to or more than 40 mm or if microinvasion is found within the biopsy specimen and less than 40% of the calcifications are removed. At least 40% of microcalcification specks should be removed from the lesion to decrease the rate of underestimation with SVAB.

  5. Assessment of RET/PTC1 and RET/PTC3 rearrangements in fine-needle aspiration biopsy specimens collected from patients with Hashimoto's thyroiditis

    Directory of Open Access Journals (Sweden)

    Cyniak-Magierska Anna

    2011-01-01

    Full Text Available Abstract Background RET/PTC rearrangements are the most frequent molecular changes in papillary thyroid carcinoma (PTC. So far, 15 main RET/PTC rearrangements have been described, among which RET/PTC1 and RET/PTC3 are the most common in PTC - especially in radiation-induced tumours. RET/PTC1 and RET/PTC3 are the result of intrachromosomal paracentric inversions in chromosome 10, where RET and the activating genes (H4 and ELE1, respectively are located. Recently, RET/PTC rearrangements have been shown not only in PTC but also in benign thyroid lesions, including Hashimoto's thyroiditis (HT. The aim of study was an assessment of RET/PTC1 and RET/PTC3 rearrangements in patients with Hashimoto's thyroiditis. Materials and methods Thyroid aspirates, eligible for the study, were obtained from 26 patients with Hashimoto's thyroiditis by fine-needle aspiration biopsy (FNAB. Each aspirate was smeared for conventional cytology, while its remaining part was immediately washed out of the needle. The cells, obtained from the needle, were used in further investigation. Total RNA from FNAB was extracted by use of an RNeasy Micro Kit, based on modified Chomczynski and Sacchi's method and reverse transcription (RT-PCR was done. Quantitative evaluation of RET/PTC1 and RET/PTC3 rearrangements by real-time PCR was performed by an ABI PRISM® 7500 Sequence Detection System. In the study, PTC tissues with known RET/PTC1 and RET/PTC3 rearrangements served as a reference standard (calibrator, while β-actin gene was used as endogenous control. Results Amplification reactions were done in triplicate for each examined sample. No RET/PTC1 and RET/PTC3 rearrangements were found in the examined samples. Conclusions Our results indicate that RET/PTC1 and RET/PTC3 rearrangements in Hashimoto's thyroiditis, if any, are rather rare events and further investigations should be conducted in order to determine molecular changes, connecting Hashimoto's thyroiditis with PTC.

  6. Cone biopsy

    Science.gov (United States)

    ... biopsy; HSIL - cone biopsy; Low-grade cone biopsy; High-grade cone biopsy; Carcinoma in situ-cone biopsy; ... the cervix. In: Baggish MS, Karram MM, eds. Atlas of Pelvic Anatomy and Gynecologic Surgery . 4th ed. ...

  7. Clinical and microbiological characterization of Staphylococcus lugdunensis isolates obtained from clinical specimens in a hospital in China

    Directory of Open Access Journals (Sweden)

    Liu Chaojun

    2012-08-01

    Full Text Available Abstract Background Several reports have associated Staphylococcus lugdunensis with the incidence of severe infection in humans; however, the frequency and prevalence of this microorganism and thus the propensity of its antimicrobial drug resistance is unknown in China. The objective of the current study was to determine the prevalence of Staphylococcus lugdunensis among six hundred and seventy non-replicate coagulase negative Staphylococcus (CoNS isolates collected in a 12-month period from clinical specimens in the General Hospital of the People’s Liberation Army in Beijing, China. Results Five (0.7% of the 670 isolates of CoNS were identified as S. lugdunensis. Whereas three isolates were resistant to erythromycin, clindamycin, and penicillin and carried the ermC gene and a fourth one was resistant to cefoxitin and penicillin and carried the mecA gene, one isolate was not resistant to any of the tested antimicrobials. Pulse field gel electrophoretic analysis did not reveal widespread epidemiological diversity of the different isolates. Conclusion Hence, even though S. lugdunensis may be yet unrecognized and undefined in China, it still might be the infrequent cause of infection and profound multi-drug resistance in the same population.

  8. COMPARSION THE HISTOPATHOLOGICAL FINDINGS AFTER CERVICAL BIOPSY AND EXCISIONAL PROCEDURES

    Directory of Open Access Journals (Sweden)

    Aljosa Mandic

    2013-01-01

    Full Text Available Introduction: A definitive diagnosis of cervical intraepithelial neoplasia (CIN is confirmed after histopathological (HP examination of the tissue obtained through the biopsy. The aim of this study was to compare histopathological results obtained with punch biopsy and results obtained through one of the excisional techniques. Material and methods: We analysed histology results of 130 patients referred to our institution with abnormal smear. Punch biopsy was performed after colposcopic examination in all patients before one of the excision methods. Excision methods performed were: large loop excision of transformation zone (LLETZ, radio-frequency knife conisation or cold knife conisation. Based on the histopathological examination of the punch biopsy specimen or excisional specimen diagnosis of CIN was established. Results: CIN and invasive cancer were the most common diagnoses in the 31–40 age group at 45.4% (59/130. Discrepancies in the histological diagnosis between punch biopsy and excisional biopsy was identified in 58.5% (76/130 of the patients. In 6% of the of the cases the biopsy did not detect an invasive carcinoma. Conclusion: The most frequent discrepancies between punch biopsy and excisional biopsy were in the group of patients with a higher grade cervical dysplasia. Mild dysplastic changes diagnosed through punch biopsy, require a more conservative approach, as the majority of this group had negative specimens on the cone after excision, especially in the younger population. It is advisable that the patients above 30 years of age and a higher grade dysplasia in the biopsy specimen, should undergo one of the excisional techniques as a diagnostic/therapeutic method of treatment.

  9. Transjugular liver biopsy : the efficacy of quick-core biopsy needle system

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Gyoo Sik; Ahn, Byung Kwon; Lee, Sang Ouk; Chang, Hee Kyong; Oh, Kyung Seung; Huh, Jin Do; Joh, Young Duk [Kosin Medical College, Pusan (Korea, Republic of)

    1998-02-01

    To evaluate the efficacy of the Quick-Core biopsy needle system in performing transjugular liver biopsy. Between December 1995 and June 1997, eight patients underwent transjugular liver biopsy involving use of the Quick-Core biopsy needle system; the conditions involved were coagulopathy (n=4), thrombocytopenia (n=3), and ascites (n=1). Via the right internal jugular vein, the right hepatic vein was selectively catheterized with a 7-F transjugular guiding catheter, and a14-guage stiffening cannula was then inserted through this catheter; to obtain core tissue, a Quick-Core needle was then advanced into the liver parenchyma through the catheter-cannula combination. Eighteen- and 19-guage needles were used in three and five patients, respectively; specimen size, adequacy of the biopsy specimen and histologic diagnosis were determined, and complications were recorded. Biopsy was successful in all patients. The mean length of the specimen was 1.4 cm (1.0 - 1.8 cm), and all were adequate for pathologic examinations ; specific diagnosis was determined in all patients. There were two malignant neoplasms, two cases of veno-occlusive disease, and one case each of cirrhosis, fulminant hepatitis, Banti syndrome and Budd-Chiari syndrome. One patient complained of neck pain after the procedure, but no serious procedural complications were noted. Our preliminary study shows that the Quick-Core biopsy needle system is safe and provides adequate core tissues with high diagnostic yields. (author). 23 refs., 1 tab., 3 figs.

  10. Transjugular liver biopsy : the efficacy of quick-core biopsy needle system

    International Nuclear Information System (INIS)

    Jung, Gyoo Sik; Ahn, Byung Kwon; Lee, Sang Ouk; Chang, Hee Kyong; Oh, Kyung Seung; Huh, Jin Do; Joh, Young Duk

    1998-01-01

    To evaluate the efficacy of the Quick-Core biopsy needle system in performing transjugular liver biopsy. Between December 1995 and June 1997, eight patients underwent transjugular liver biopsy involving use of the Quick-Core biopsy needle system; the conditions involved were coagulopathy (n=4), thrombocytopenia (n=3), and ascites (n=1). Via the right internal jugular vein, the right hepatic vein was selectively catheterized with a 7-F transjugular guiding catheter, and a14-guage stiffening cannula was then inserted through this catheter; to obtain core tissue, a Quick-Core needle was then advanced into the liver parenchyma through the catheter-cannula combination. Eighteen- and 19-guage needles were used in three and five patients, respectively; specimen size, adequacy of the biopsy specimen and histologic diagnosis were determined, and complications were recorded. Biopsy was successful in all patients. The mean length of the specimen was 1.4 cm (1.0 - 1.8 cm), and all were adequate for pathologic examinations ; specific diagnosis was determined in all patients. There were two malignant neoplasms, two cases of veno-occlusive disease, and one case each of cirrhosis, fulminant hepatitis, Banti syndrome and Budd-Chiari syndrome. One patient complained of neck pain after the procedure, but no serious procedural complications were noted. Our preliminary study shows that the Quick-Core biopsy needle system is safe and provides adequate core tissues with high diagnostic yields. (author). 23 refs., 1 tab., 3 figs

  11. Transjugular Liver Biopsy: Results of 97 Patients

    Directory of Open Access Journals (Sweden)

    Kemal Deniz

    2012-06-01

    Full Text Available Objective: To evaluate the feasibility and efficacy of transjugular liver biopsy in patients with contraindicated percutaneous biopsy.Materials and Methods: Between June 2005 and April 2010, 97 patients who were admitted for transjugular liver biopsy were enrolled in this retrospective study. All liver biopsies were obtained using an 18 gauge Quick-Core liver biopsy set through the right hepatic vein via the internal jugular vein. Clinical indication, histopathological diagnosis, and complications were noted.Results: Primary technical success was achieved in 93 (95.8% patients. Hepatic veins could not be catheterized and opacified in two patients and in the remaining two patients the veins could be opacified and catheterized but we were not able to pass the biopsy needle into the hepatic vein because of the acute angle between the inferior vena cava and hepatic veins. At least two specimens were obtained from each patient. The most frequent histopathological diagnosis was cirrhosis. A subcutaneous hematoma around the puncture side was encountered in one patient.Conclusion: Transjugular liver biopsy is a feasible and effective alternative in patients with contraindication for percutaneous biopsy.

  12. The relative test performance characteristics of two commercial assays for the detection of Mycobacterium tuberculosis complex in paraffin-fixed human biopsy specimens

    Directory of Open Access Journals (Sweden)

    Broukhanski George

    2008-09-01

    Full Text Available Abstract The Seeplex™ TB Detection-2 assay (Rockville, MD is a nested endpoint PCR for the Mycobacterium tuberculosis complex (MTBC targets IS6110 and MPB64 that utilizes dual priming oligonucleotide technology. When used to detect the presence of MTBC DNA in formalin-fixed paraffin-embedded tissue specimens, the sensitivity and specificity of this assay is equivalent to a labor-intensive traditional endpoint PCR assay and is more sensitive than a commercial real-time PCR assay.

  13. Effects of staple size, tissue thickness, and precompression time on staple shape in side-to-side jejunocecal anastomosis in specimens obtained from healthy horses at an abattoir.

    Science.gov (United States)

    Giusto, Gessica; Gandini, Marco; Amedeo, Stefano

    2014-07-01

    To determine effects of staple size, precompression time, and tissue thickness on staple shape and tissue approximation in side-to-side jejunocecal anastomosis in equine specimens. Cecum, ileum, and jejunum specimens obtained from 18 healthy horses at an abattoir. Specimens were allotted into 2 groups. Anastomoses were stapled with 4.8-or 3.8-mm staples. Precompression time was 15 seconds for both groups. Staple lines were cut into proximal, middle, and distal sections. Thickness of intestinal walls was measured with a calibrated tissue micrometer, photographs were obtained, and intestinal tissues were digested. An investigator measured staples and assessed the shape of staples on high-definition digital images. Number of optimally shaped staples and staple height were compared among sections and between groups. Use of 4.8-mm staples resulted in poor approximation of tissues in the distal sections of anastomoses. The percentage of optimally shaped staples was 538 of 551 (97.6%) and 616 of 634 (97.2%) for 4.8- and 3.8-mm staples, respectively. The percentage of optimally shaped staples did not differ significantly between groups for the same sections. There was a lower percentage of optimally shaped staples in the distal sections than in the proximal and middle sections of each group. Mean staple height did not differ significantly among sections of each group. Use of 3.8-mm staples with an adequate precompression time for jejunocecal anastomosis in horses resulted in proper staple shape. These findings could be used to improve the technique and outcome for stapled jejunocecal anastomoses in horses.

  14. Production of 16N and obtaining of its gamma spectrum in order to calibrate detectors or determination of fluorine in geological specimens

    International Nuclear Information System (INIS)

    Rey-Ronco, M.A.; Alonso-Sanchez, T.; Castro-Garcia, M.P.

    2010-01-01

    In this paper, we show a procedure for producing 16 N and a method to obtain its gamma spectrum with a NaI(Tl) detector. We also demonstrate the interest of this radioactive element for the purpose of NaI(Tl) detector calibration and for the determination of fluorine in geological specimens using an Alpha Beryllium neutron source. This work consists of a theoretical study which analyzes the characteristics of 16 N and nuclear reactions that originate from an Americium Beryllium source of 1Ci activity. We justify our choice of reaction 19 F(n,α) 16 N and the use of fluorspar as a source of fluorine. The mathematical procedure followed to obtain the gamma rays spectrum produced by 16 N in a NaI(Tl) detector is shown.

  15. Production of {sup 16}N and obtaining of its gamma spectrum in order to calibrate detectors or determination of fluorine in geological specimens

    Energy Technology Data Exchange (ETDEWEB)

    Rey-Ronco, M.A., E-mail: rey@uniovi.e [Departamento de Energia, Universidad de Oviedo, 33004 Oviedo (Spain); Alonso-Sanchez, T., E-mail: tjalonso@uniovi.e [Departamento de Explotacion y Prospeccion de Minas, Universidad de Oviedo, 33004 Oviedo (Spain); Castro-Garcia, M.P., E-mail: UO21947@uniovi.e [Departamento de Explotacion y Prospeccion de Minas, Universidad de Oviedo, 33004 Oviedo (Spain)

    2010-09-15

    In this paper, we show a procedure for producing {sup 16}N and a method to obtain its gamma spectrum with a NaI(Tl) detector. We also demonstrate the interest of this radioactive element for the purpose of NaI(Tl) detector calibration and for the determination of fluorine in geological specimens using an Alpha Beryllium neutron source. This work consists of a theoretical study which analyzes the characteristics of {sup 16}N and nuclear reactions that originate from an Americium Beryllium source of 1Ci activity. We justify our choice of reaction {sup 19}F(n,{alpha}){sup 16}N and the use of fluorspar as a source of fluorine. The mathematical procedure followed to obtain the gamma rays spectrum produced by {sup 16}N in a NaI(Tl) detector is shown.

  16. Liver biopsy

    Science.gov (United States)

    Biopsy - liver; Percutaneous biopsy ... the biopsy needle to be inserted into the liver. This is often done by using ultrasound. The ... the chance of damage to the lung or liver. The needle is removed quickly. Pressure will be ...

  17. Fluoroscopy-Guided Percutaneous Vertebral Body Biopsy Using a Novel Drill-Powered Device: Technical Case Series

    Energy Technology Data Exchange (ETDEWEB)

    Wallace, Adam N., E-mail: wallacea@mir.wustl.edu; Pacheco, Rafael A., E-mail: pachecor@mir.wustl.edu; Tomasian, Anderanik, E-mail: tomasiana@mir.wustl.edu [Washington University School of Medicine, Mallinckrodt Institute of Radiology (United States); Hsi, Andy C., E-mail: hsia@path.wustl.edu [Washington University School of Medicine, Division of Anatomic Pathology, Department of Pathology & Immunology (United States); Long, Jeremiah, E-mail: longj@mir.wustl.edu [Washington University School of Medicine, Mallinckrodt Institute of Radiology (United States); Chang, Randy O., E-mail: changr@wusm.wustl.edu [Washington University School of Medicine (United States); Jennings, Jack W., E-mail: jenningsj@mir.wustl.edu [Washington University School of Medicine, Mallinckrodt Institute of Radiology (United States)

    2016-02-15

    BackgroundA novel coaxial biopsy system powered by a handheld drill has recently been introduced for percutaneous bone biopsy. This technical note describes our initial experience performing fluoroscopy-guided vertebral body biopsies with this system, compares the yield of drill-assisted biopsy specimens with those obtained using a manual technique, and assesses the histologic adequacy of specimens obtained with drill assistance.MethodsMedical records of all single-level, fluoroscopy-guided vertebral body biopsies were reviewed. Procedural complications were documented according to the Society of Interventional Radiology classification. The total length of bone core obtained from drill-assisted biopsies was compared with that of matched manual biopsies. Pathology reports were reviewed to determine the histologic adequacy of specimens obtained with drill assistance.ResultsTwenty eight drill-assisted percutaneous vertebral body biopsies met study inclusion criteria. No acute complications were reported. Of the 86 % (24/28) of patients with clinical follow-up, no delayed complications were reported (median follow-up, 28 weeks; range 5–115 weeks). The median total length of bone core obtained from drill-assisted biopsies was 28 mm (range 8–120 mm). This was longer than that obtained from manual biopsies (median, 20 mm; range 5–45 mm; P = 0.03). Crush artifact was present in 11 % (3/28) of drill-assisted biopsy specimens, which in one case (3.6 %; 1/28) precluded definitive diagnosis.ConclusionsA drill-assisted, coaxial biopsy system can be used to safely obtain vertebral body core specimens under fluoroscopic guidance. The higher bone core yield obtained with drill assistance may be offset by the presence of crush artifact.

  18. Transvitreal Retinochoroidal Biopsy Provides a Representative Sample From Choroidal Melanoma for Detection of Chromosome 3 Aberrations

    DEFF Research Database (Denmark)

    Bagger, Mette; Andersen, Morten T.; Heegaard, Steffen

    2015-01-01

    PURPOSE: To compare the status of chromosomes 3 and 8 in 25-gauge transvitreal retinochoroidal (TVRC) biopsy specimens and enucleated eyes in order to evaluate for genetic heterogeneity and the utility of TVRC biopsy to obtain an adequate sampling of the tumor. METHODS: Genetic heterogeneity...

  19. Relative quantification of PIK3CA gene expression level in fine-needle aspiration biopsy thyroid specimens collected from patients with papillary thyroid carcinoma and non-toxic goitre by real-time RT-PCR

    Directory of Open Access Journals (Sweden)

    Wojciechowska-Durczyńska Katarzyna

    2010-08-01

    Full Text Available Abstract Background Recent studies have shown that the phosphatidylinositol 3-kinase (PI3K signaling pathway is important regulator of many cellular events, including apoptosis, proliferation and motility. PI3K pathway alterations (PIK3CA gene mutations and/or amplification have been observed in various human tumours. In the majority of diagnosed cases, mutations are localized in one of the three "hot spots" in the gene, responsible for coding catalytic subunit α of class I PI3K (PIK3CA. Mutations and amplification of PIK3CA gene are characteristic for thyroid cancer, as well. Methods The aim of our study was to examine a gene expression level of PIK3CA in fine-needle aspiration biopsy (FNAB thyroid specimens in two types of thyroid lesions, papillary thyroid carcinoma (PTC and non-toxic goitre (NTG. Following conventional cytological examination, 42 thyroid FNAB specimens, received from patients with PTC (n = 20 and NTG (n = 22, were quantitatively evaluated regarding PIK3CA expression level by real-time PCR in the ABI PRISM® 7500 Sequence Detection System. Results Significantly higher expression level (RQ of PIK3CA in PTC group has been noted in comparison with NTG group (p Conclusion These observations may suggest role of PIK3CA alterations in PTC carcinogenesis.

  20. Ultrasound-guided forceps for pleural biopsy

    Directory of Open Access Journals (Sweden)

    Gamal Agmy

    2014-04-01

    Clinical implications: Ultrasound-guided forceps for pleural biopsy can overcome many of the limitations of the conventional needle biopsy procedures, provides multiple biopsy specimens of the parietal pleura that are inaccessible to the biopsy needle, and can be carried out easily and safely even in sick and obese patients. The diagnostic yield is nearly similar to thoracoscopy.

  1. Analysis of histological findings obtained combining US/mp-MRI fusion-guided biopsies with systematic US biopsies: mp-MRI role in prostate cancer detection and false negative.

    Science.gov (United States)

    Faiella, Eliodoro; Santucci, Domiziana; Greco, Federico; Frauenfelder, Giulia; Giacobbe, Viola; Muto, Giovanni; Zobel, Bruno Beomonte; Grasso, Rosario Francesco

    2018-02-01

    To evaluate the diagnostic accuracy of mp-MRI correlating US/mp-MRI fusion-guided biopsy with systematic random US-guided biopsy in prostate cancer diagnosis. 137 suspected prostatic abnormalities were identified on mp-MRI (1.5T) in 96 patients and classified according to PI-RADS score v2. All target lesions underwent US/mp-MRI fusion biopsy and prostatic sampling was completed by US-guided systematic random 12-core biopsies. Histological analysis and Gleason score were established for all the samples, both target lesions defined by mp-MRI, and random biopsies. PI-RADS score was correlated with the histological results, divided in three groups (benign tissue, atypia and carcinoma) and with Gleason groups, divided in four categories considering the new Grading system of the ISUP 2014, using t test. Multivariate analysis was used to correlate PI-RADS and Gleason categories to PSA level and abnormalities axial diameter. When the random core biopsies showed carcinoma (mp-MRI false-negatives), PSA value and lesions Gleason median value were compared with those of carcinomas identified by mp-MRI (true-positives), using t test. There was statistically significant difference between PI-RADS score in carcinoma, atypia and benign lesions groups (4.41, 3.61 and 3.24, respectively) and between PI-RADS score in Gleason  7 group (4.14 and 4.79, respectively). mp-MRI performance was more accurate for lesions > 15 mm and in patients with PSA > 6 ng/ml. In systematic sampling, 130 (11.25%) mp-MRI false-negative were identified. There was no statistic difference in Gleason median value (7.0 vs 7.06) between this group and the mp-MRI true-positives, but a significant lower PSA median value was demonstrated (7.08 vs 7.53 ng/ml). mp-MRI remains the imaging modality of choice to identify PCa lesions. Integrating US-guided random sampling with US/mp-MRI fusion target lesions sampling, 3.49% of false-negative were identified.

  2. Utility of abdominal skin plus subcutaneous fat and rectal mucosal biopsy in the diagnosis of AL amyloidosis with renal involvement.

    Directory of Open Access Journals (Sweden)

    Ting Li

    Full Text Available Skin fat biopsy of the abdominal wall is a simple and safe method for detecting amyloidosis, and rectal mucosal biopsy is also frequently used for screening for the disease; however, the sensitivity of these approaches has not been fully studied. The aim of this study was to evaluate the efficacy of skin fat biopsy combined with rectal mucosal biopsy as a screening procedure for the diagnosis of systemic immunoglobulin light-chain (AL amyloidosis.We retrospectively analyzed 224 AL amyloidosis patients confirmed by renal biopsy, including a test group of 165 patients and validation group of 59 patients. Surgical skin fat biopsy from the abdominal wall and rectal mucosal biopsy under endoscopy was performed to obtain specimens. Congo red staining and immunofluorescence staining with antibodies against light chains were performed to type the disease. Pathology reports were reviewed to assess the diagnostic sensitivity of skin fat biopsy and rectal mucosal biopsy. Diagnostic specificity was not examined in the present study, because no healthy volunteers and only few patients with other diseases had performed immunofluorescence staining on skin fat and rectal specimens.Of the 165 patients in the test group, Congo red staining of skin fat and rectal mucosal specimens was associated with a sensitivity of 89.3% and 94.8%, respectively. The sensitivity increased to 98.9% by combining both biopsy methods. Immunofluorescence stains were positive in 81.1% of patients undergoing skin fat biopsy and 84.7% of patients undergoing rectal mucosal biopsy. Immunofluorescence stains yielded positive results in 86.7% of cases combining skin fat biopsy with rectal mucosal biopsy. The diagnostic results also performed well in the validation group.Surgical skin biopsy including the subcutaneous fat pad can be performed safely at the bedside and is useful for diagnosing AL amyloidosis. Combining skin fat biopsy with rectal mucosal biopsy may identify amyloid deposits in

  3. Evaluation of a manual biopsy device, the 'Spirotome', on fresh canine organs: liver, spleen, and kidneys, and first clinical experiences in animals.

    Science.gov (United States)

    Vignoli, Massimo; Barberet, Virginie; Chiers, Koen; Duchateau, Luc; Bacci, Barbara; Terragni, Rossella; Rossi, Federica; Saunders, Jimmy H

    2011-03-01

    Several methods for obtaining specimens from abdominal organs have been described. Imaging-guided biopsy, particularly ultrasound-guided biopsy, is the most frequently used in clinical trials. The aim of this study was to evaluate the diagnostic quality of histological samples obtained with a manual biopsy device (Spirotome) on biopsies of the liver, spleen, and kidney, in fresh canine organs and in live animals in a clinical trial. The study was divided into two different parts, one using normal fresh canine organs with a total of 60 biopsies, 20 of liver, spleen, and kidney, respectively; and one on clinical patients, including 35 biopsied lesions in 28 animals (25 dogs and three cats) for a total of 95 biopsies. All the biopsy samples were considered satisfactory from canine cadavers, and all specimens were diagnostic in clinical cases. The technique was accurate and safe and no major complications were noted.

  4. Clinical value of detection of HPL-expressing intermediate trophoblasts in abortion or curettage-obtained specimens for diagnosis of intrauterine or ectopic pregnancies

    International Nuclear Information System (INIS)

    He Xiaomei; Wang Yuping; Wang Lisha; Yang Jingxiu; Gao Xueyan

    2005-01-01

    Objective: To investigate the value of detection of HPL-expressing intermediate trophoblasts in endometrial specimens for diagnosis of intrauterine and ectopic pregnancies. Methods: The examined specimens included: (1) Group I, 35 specimens with suspected intermediate trophoblast in decidua (2) Group II, 30 specimens with decidua-like plump endometrial stroma cells and/ or A-S phenomena in glandular epithelium (3) 30 specimens from proven intrauterine pregnancies serving as controls. Histochemistry (SP method) was used for HPL detection in all these specimens. Results: In the 30 proven intrauterine pregnancies, decidua and villa were present in all the specimens. Only 24 of the 30 were found to be HPL(+) with 6 HPL negatives (20%). In Group I , 28 of the 35 specimens were found to be HPL(+) and all of 28 were from intrauterine pregnancies: Of the 7 HPL negative cases, 5 were later confirmed as with ectopic pregnancy, the remaining 2 were with intrauterine pregnancy. In Group II, 22 of 30 specimens were HPL(+) and all were from intrauterine pregnancy. Of the 8 HPL negative cases, 6 were later confirmed as with ectopic pregnancy and 2 were with intrauterine pregnancy. Combining the data from Group I and II, we could see that in the total 15 HPL negative cases, 11 were with ectopic pregnancy (11/15=73.3%) and 4 were with intrauterine pregnancy (4/15=26.7%). Conclusion: In specimens of intrauterine contents, demonstration of HPL (+) cells could be regarded as confirmative evidence of intrauterine pregnancy. However, the reverse did not hold true. Many of the HPL negative specimens were from intrauterine pregnancies (in this study 4/15 or 26.7%). Therefore, in HPL negative cases, there was a high possibility of ectopic pregnancy but further examinations were required to ascertain the diagnosis. (authors)

  5. Pesquisa de Mycobacterium leprae em biópsias de mucosa oral por meio da reação em cadeia da polimerase Molecular detection of Mycobacterium leprae by polymerase chain reaction in oral mucosa biopsy specimens

    Directory of Open Access Journals (Sweden)

    Geraldo Gomes dos Santos

    2007-06-01

    Full Text Available FUNDAMENTOS - A hanseníase é endêmica na América do Sul, sendo responsável por 3% do total dos casos mundiais e, particularmente, no Brasil, por 85% dos casos sul-americanos. Seu agente pode ser encontrado na mucosa oral sem qualquer alteração evidente, e apenas testes laboratoriais muito sensíveis podem detectar sua presença. OBJETIVOS - Determinar se o genoma do Mycobacterium leprae pode ser encontrado pelo teste da PCR em biópsias com punch da mucosa oral de pacientes com hanseníase. MATERIAL E MÉTODOS - Realizou-se biópsia da mucosa oral normal de sete pacientes com hanseníase multibacilar. Cinco estavam em tratamento durante o estudo, e apenas um, ainda sem tratamento, teve o diagnóstico confirmado pela hematoxilina-eosina e coloração de Fite-Faraco para M. leprae. As peças foram incluídas em parafina e submetidas à PCR para pesquisa de M. leprae. RESULTADOS - Seis dos sete casos foram positivos para M. leprae, e um para Mycobacterium sp., demonstrando-se alta sensibilidade e especificidade do método. CONCLUSÃO - A PCR é método rápido, fácil e confiável para a investigação de rotina da infecção por micobactéria, mesmo quando a doença ainda é assintomática. O diagnóstico pode ser obtido a partir de simples biópsia ambulatorial.BACKGROUND - Hansen's disease is endemic in South America, which accounts for 3% of total world cases, and particularly in Brazil, which accounts for 85% of all South American cases. The bacteria can be found in the oral mucosa with no evident signs of infection, and only very sensitive laboratory assays can detect its presence. OBJECTIVES - The aim of this study was to ascertain if the M. leprae genome can be detected by PCR in small punch biopsy specimens from the oral mucosa of patients with Hansen's disease. METHODS - The normal oral mucosas of seven multibacillary Hansen's disease patients were biopsied. Five of them were under treatment at the time of the study. Diagnosis of

  6. Tongue biopsy

    Science.gov (United States)

    Biopsy - tongue ... A tongue biopsy can be done using a needle. You will get numbing medicine at the place where the ... provider will gently stick the needle into the tongue and remove a tiny piece of tissue. Some ...

  7. The value of percutaneous trephine biopsy in the diagnosis of ...

    African Journals Online (AJOL)

    The results obtained in 55 adult patients with sinister lesions of vertebral bodies, who were subjected to percutaneous trephine biopsy, are presented. A positive diagnosis was made on histopathological examination of specimens from 24 patients (44%). In the remaining 31 patients (56%), pathological features were seen ...

  8. Small intestinal biopsies in celiac disease: duodenal or jejunal?

    NARCIS (Netherlands)

    Meijer, JW; Wahab, PJ; Mulder, C.J.J.

    2003-01-01

    BACKGROUND: For diagnosis and follow-up of celiac disease, pediatric societies advise that intestinal mucosal specimens should be obtained using suction capsule from the jejunum. This procedure is strenuous for patients, time-consuming, expensive and requires radiographic guidance. Mucosal biopsies

  9. Molecular Typing and Virulence Gene Profiles of Enterotoxin Gene Cluster (egc)-Positive Staphylococcus aureus Isolates Obtained from Various Food and Clinical Specimens.

    Science.gov (United States)

    Song, Minghui; Shi, Chunlei; Xu, Xuebing; Shi, Xianming

    2016-11-01

    The enterotoxin gene cluster (egc) has been proposed to contribute to the Staphylococcus aureus colonization, which highlights the need to evaluate genetic diversity and virulence gene profiles of the egc-positive population. Here, a total of 43 egc-positive isolates (16.2%) were identified from 266 S. aureus isolates that were obtained from various food and clinical specimens in Shanghai. Seven different egc profiles were found based on the polymerase chain reaction (PCR) result for egc genes. Then, these 43 egc-positive isolates were further typed by multilocus sequence typing, pulsed-field gel electrophoresis (PFGE), multiple-locus variable-number tandem-repeat analysis (MLVA), and accessory gene regulatory (agr) typing. It showed that the 43 egc-positive isolates displayed 17 sequence types, 28 PFGE patterns, 29 MLVA types, and 4 agr types, respectively. Among them, the dominant clonal lineage was CC5-agr II (48.84%). Thirty toxin and 20 adhesion-associated genes were detected by PCR in egc-positive isolates. Notably, invasive toxin genes showed a high prevalence, such as 76.7% for Panton-Valentine leukocidin encoding genes, 27.9% for sec, and 23.3% for tsst-1. Most of the examined adhesion-associated genes were found to be conserved (76.7-100%), whereas the fnbB gene was only found in 8 (18.6%) isolates. In addition, 33 toxin gene profiles and 13 adhesion gene profiles were identified, respectively. Our results imply that isolates belonging to the same clonal lineage harbored similar adhesion gene profiles but diverse toxin gene profiles. Overall, the high prevalence of invasive virulence genes increases the potential risk of egc-positive isolates in S. aureus infection.

  10. Usefulness of the coaxial technique in US-guided breast core biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong Hyun; Lee, Jeong Hwa; Ha, Jeon Ju; Lee, Keon; Kim, Won Ho; Kwon, Jung Hyeok [Dongkang general hospital, Seoul (Korea, Republic of); Ham, Soo Youn [Ulsan Univ. Hospital, Ulsan (Korea, Republic of)

    1999-05-01

    To evaluate the usefulness of the coaxial technique in US-guided breast core biopsy. Using the coaxial technique, US-guided breast core biopsy was performed in 49 breast lesions (40 patients). Under US-guidance the 17-gauge, 13 cm long introducer needle was positioned proximal to the lesion. Once the needle was in place, the central trocar was removed and was replaced with the core biopsy needle. We used an 18-gauge, 16-cm-long core biopsy needle with a 17 mm specimen notch. Four to eight tissue specimens were obtained from each lesion, and the quality and quantity of specimens, procedure time, and complications and their rate were evaluated. For 48 of 49 lesions, specimens were adequate for histopathologic diagnosis, and the findings were as follows : six cases of invasive ductal carcinoma, one of ductal carcinoma in situ, 29 of fibrocystic disease, eight of fibroadenoma, two of chronic inflammation, and two of sclerosing lesion. In 12 lesions agreement between the pathologic results of needle core biopsy and surgical results was 100%. The procedure time was about 15 minutes and no significant complications were noted. In breast core biopsy, the coaxial technique is simple and time-saving, and compared with standard breast core biopsy, may also be less traumatic and decrease the potential risk of seeding the biopsy tract with malignant cells.

  11. Compatibility study of the different pole figures in one and the same specimen. Comparison between the results obtained by neutron and by X-ray diffraction

    International Nuclear Information System (INIS)

    Pernot, M.; Penelle, R.; Dervin, P.

    1981-01-01

    Development of a calculation to show directly the compatibility of the different pole figures in the same specimen is exposed. A review of the method by serial development is given. Experimental methods are described. The position of the anisotropy axes is determined. Compatibilities resulting from X-ray and from neutron diffraction is analysed [fr

  12. Radiologically Guided Bone Biopsy: Results of 502 Biopsies

    International Nuclear Information System (INIS)

    Ng, Chaan S.; Salisbury, Jonathan R.; Darby, Alan J.; Gishen, Philip

    1998-01-01

    Purpose: To analyze the results of 502 biopsies over a 19-year period for the purpose of highlighting the results that can be expected from such a large study, with emphasis on needle choice and anesthetic methods. Methods: The histological, cytological, and microbiological results of 477 patients who had 502 bone biopsies carried out between July 1977 and March 1996 were studied. Less than 5% of patients required second biopsies. There were almost equal numbers of males and females in the group. The lesions were visible radiologically and most of the biopsies were carried out by a single operator. The lesions were classified on their histopathological, cytopathological, and microbiological findings. Results: Tumors accounted for 40% of the biopsies, and infection for 16%. Biopsies which did not yield a 'positive' diagnosis accounted for 31%; these included specimens reported as normal, or as showing reactive changes, repair, remodelling, non-specific features, inflammation (but not clearly infective), or no evidence of malignancy or inflammation. Less than 4% of biopsies were incorrect, and some of these were re-biopsied. Conclusion: Bone biopsy is a valuable technique for positive diagnosis of malignancy or infection, as it enables a definitive plan for treatment and management of patients to be established. Exclusion of serious pathology is almost equally important. In principle, any osseous site can be biopsied using fluoroscopic or computed tomographic guidance. Care in the biopsy technique and selection of the bone needle is required

  13. Detection of foot-and-mouth disease virus RNA in pharyngeal epithelium biopsy samples obtained from infected cattle: Investigation of possible sites of virus replication and persistence

    DEFF Research Database (Denmark)

    Stenfeldt, Anna Carolina; Belsham, Graham

    2012-01-01

    Foot-and-mouth disease (FMD) is a highly contagious viral infection of significant financial importance to the export and trade of agricultural products. The occurrence of persistently infected ‘‘carriers’’ of FMD-virus (FMDV) in ruminant species adds further complications to disease control....... There have been significant discrepancies in reports regarding the pathogenesis of FMDV infection in cattle with specific emphasis on the anatomical sites involved in early and persistent virus replication. In this study, collection of small biopsy samples from the dorsal soft palate (DSP) of live animals...... was used to investigate the level of FMDV RNA present at this site at sequential time points during the infection. Results were compared to measurements of virus excretion in samples of oropharyngeal fluid collected at corresponding time points. Possible sites of virus persistence were investigated through...

  14. Characteristics of colon cancer among atomic bomb exposure obtained from autopsy specimen at data and specimens center of atomic bomb disaster at Research Institute for Nuclear Medicine and Biology of Hiroshima University

    International Nuclear Information System (INIS)

    Ito, Akihiro; Kagawa, Naoki; Watanabe, Hiromitsu; Fukazawa, Kiichi; Hayakawa, Norihiko; Munaka, Masami

    1989-01-01

    Autopsy data of colon cancer from 135 A-bomb survivors (Group A) found during the period 1952-1981 were analyzed in terms of sex, age, site of occurrence, distance from the hypocenter, and histology. Control data were collected from 72 patients with surgery or biopsy proven colon cancer (Group B) found during the period 1983-1987. Patients consisted of 76 men and 59 women in Group A, and 44 men and 28 women in Group B. According to age groups, patients aged ≤50 years, between the ages of 51 and 70, and ≥71 years accounted for 16%, 44%, and 40%, respectively, in Group A. The corresponding figures in Group B were 18%, 36%, and 46%. The commonest site in Group A was the rectum (45.9%), followed by the descending colon and sigmoid colon (27.4%), and the ileocecum and ascending colon (20%). In Group B, the descending colon and sigmoid colon were the commonest site (41.7%), followed by the rectum (40.3%) and the ileocecum and ascending colon (9.7%). Patients in Group A tended to have colon cancer on the right side; it was observed in 23% of A-bomb survivors exposed at up to 2500 m from the hypocenter and in 14.8% of those exposed at a distance of over 2500 m. Histology revealed well differentiated adenocarcinoma in 78% in both groups. Both poorly differentiated and mucocellular adenocarcinomas occupied 13.4% in Group A, as compared with 4.2% in Group B. (N.K.)

  15. Nail biopsy: A user's manual

    Directory of Open Access Journals (Sweden)

    Chander Grover

    2018-01-01

    Full Text Available Nail biopsy is a procedure not routinely resorted to; but when indicated, it is often the only clue left for diagnosis. At such times, it pays to be conversant with it. It is an investigation that not only provides etiologic, diagnostic, and prognostic information but also aids in understanding the pathogenesis of nail diseases. It can be of therapeutic value, especially with respect to nail tumors. This article compiles the procedural techniques for nail biopsy of various types and attempts to summarize the evidence available in the literature. The objective of nail biopsy is to clinch a precise diagnosis of nail pathology with a simple and safe surgical procedure, avoiding pain or permanent nail damage. Patient selection is of utmost importance, wherein, the patient does not have typical skin lesions, yields inadequate information on routine nail investigations, and has no peripheral vascular compromise. The patient needs to be explained about the risks associated, the expected functional handicap, the time required for regrowth, a possibility of permanent nail dystrophy, and a possibility of not achieving a diagnosis even after the biopsy. Techniques and types of various nail biopsies are being discussed in this article. The specimen could be collected as an excision biopsy, punch biopsy, shave biopsy, or longitudinal biopsy. The trick lies in choosing the appropriate area for biopsy. Various biopsy types discussed in this article include nail plate biopsy (easiest and least scarring; nail bed biopsy (elliptical excision or punch; nail matrix biopsy (elliptical excision, punch excision (≤3 mm or tangential/shave excision; and nail fold biopsy. Complications reported along with means to minimize them are also discussed.

  16. Endometrial biopsy

    Science.gov (United States)

    ... due to changes in hormone levels ( anovulatory bleeding ) Risks Risks of endometrial biopsy include: Infection Causing a ... American College of Obstetricians and Gynecologists, Group Health Cooperative, Bellevue, WA. Also reviewed by David Zieve, MD, ...

  17. Bone Biopsy

    Science.gov (United States)

    ... bear denotes child-specific content. Related Articles and Media Computed Tomography (CT) - Body Magnetic Resonance Imaging (MRI) - Body X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Bone Biopsy Sponsored by Please note ...

  18. Skin Biopsy

    Science.gov (United States)

    ... tape it closed with small strips of clear, sticky tape. If you get stitches, your doctor will ... of Your Skin Melanoma Eczema Aspiration and Biopsy: Bone Marrow Impetigo Pityriasis Rosea View more Partner Message ...

  19. CT-guided bone biopsy in cancer patients with suspected bone metastases: retrospective review of 308 procedures.

    Science.gov (United States)

    Monfardini, Lorenzo; Preda, Lorenzo; Aurilio, Gaetano; Rizzo, Stefania; Bagnardi, Vincenzo; Renne, Giuseppe; Maccagnoni, Sara; Vigna, Paolo Della; Davide, Disalvatore; Bellomi, Massimo

    2014-11-01

    The authors assessed the adequacy and sensitivity of CT-guided bone biopsy in 308 procedures performed in 286 cancer patients with suspected bone metastases. An electronic search of our CT-guided bone biopsy database was retrospectively performed to evaluate the adequacy of samples and, in the event of negative samples, whether the patients had radiological progression at the site of biopsy (false negative). Adequacy and false-negative rate were compared with radiological features, biopsy location, specimen length and complications to assess any statistically relevant association with a multivariate logistic regression model. A total of 290/308 (94.1 %) samples were adequate. Forty-five patients had normal bone marrow and were followed-up, with evidence of progression at the site of biopsy in 10 cases (false-negative cases); overall sensitivity was 96.7 %. Specimen length was significantly correlated to the probability of an adequate biopsy (p = 0.035) and inversely correlated to the probability to obtain a false-negative result (p = 0.02). We encountered 11/308 (3.5 %) minor complications and no major complications. CT-guided biopsy of bone lesions in cancer patients allows for a final diagnosis in 94 % of cases. A specimen longer than 1 cm may lead to a significant result in terms of adequacy and sensitivity. Negative biopsies with positive positron emission tomography or magnetic resonance imaging and specimen shorter than 1 cm should be repeated to avoid a false-negative result.

  20. Does Prebiopsy, Nonsterile Ultrasonography Gel Affect Biopsy-Site Asepsis?

    International Nuclear Information System (INIS)

    Gurel, Kamil; Karabay, Oguz; Gurel, Safiye; Hildebolt, Charles

    2008-01-01

    Purpose. The purpose of this study was to determine the extent to which the use of nonsterile gel, prior to antiseptic procedures in ultrasonography (US)-guided percutaneous biopsies, results in contamination of the biopsy site. Materials and Methods. Patients referred for US-guided percutaneous biopsies were included in this study. Transmission material used for US evaluation before biopsy-site antiseptic procedures were performed was either nonsterile gel or sterile saline. Patients were randomly assigned to two groups: nonsterile gel (n = 30) and sterile saline (n = 30). Before the transmission material was used and after antiseptic procedures were performed, microbial swabs of a 10-cm 2 -diameter area were obtained at the biopsy site. Swabs were also obtained from the gel, saline, and povidine-iodine. Inoculated specimen plates were incubated at 37 o C under aerobic conditions, and the numbers of colony-forming units recorded. Nominal logistic regression analysis was used to calculate the odds of postantisepsis bacterial growth (after antiseptic procedures were performed) based on group, gender, coincidental disease (diabetes, chronic renal failure, and malignancy), biopsy-site location (head and neck or breast and abdomen), and local factors (skin fold, skin tag, and hair). Results. The following odds ratios (adjusted for the other variables) and their 95% confidence intervals were calculated: (1) group (2.9 [0.8-11.1]; p = 0.10); (2) gender (1.2 [0.3-5.2]; p = 0.78); (3) coincidental disease (7.6 [0.9-166.7]; p = 0.09); (4) biopsy site location (6.2 [1.4-31.3]; p = 0.02); and (5) local factors (7.0 [1.6-36.0]; p = 0.01). No bacterial growth occurred with swabs obtained from gel, povidine-iodine, or saline. Conclusion. We conclude that nonsterile gel used prior to percutaneous biopsy does not affect biopsy-site asepsis

  1. CT-guided core-needle biopsy in omental pathology

    International Nuclear Information System (INIS)

    Pombo, F.; Rodriguez, E.; Martin, R.; Lago, M.

    1997-01-01

    Purpose: To assess the accuracy and clinical usefulness of CT-guided core-needle biopsy in the diagnosis of omental pathology. Material and Methods: We retrospectively reviewed the results of CT-guided percutaneous core biopsies in 25 patients with focal (n=2) or diffuse (n=23) omental pathology. These results were compared to the final diagnoses as determined by laparotomy (n=15), laparoscopic biopsy (n=3), endoscopic biopsy (n=1), or by the results of percutaneous biopsy and clinical-radiological and bacteriological modalities (n=6). The final diagnoses showed 4 patients with isolated omental pathology and 21 with widespread peritoneal involvement. The CT-guided biopsies were performed with 1.0=1.8-mm Surecut core-needles. Results: In 16 patients, the final diagnosis was metastatic adenocarcinoma - with the primary tumor sites in the ovary (n=3), stomach (n=1), appendix (n=2), and unknown (n=10). In the remaining 9 patients, the final diagnosis was hepatocellular carcinoma, lymphoma, and mesothelioma in 1 patient each; tuberculosis in 5; and actinomycosis in 1. Sufficient histological (n=16) or cytological (n=8) material was obtained by CT biopsy in 24/25 (96%) cases; the specimen was insufficient for diagnosis in 1 case. In differentiating benign from malignant disease, CT-guided biopsy showed a sensitivity, specificity and accuracy of respectively 89.5%, 100% and 92%. It gave a specific diagnosis in 78.9% (15/19) of patients with malignant conditions and in 50% (3/6) of patients with benign disorders. There were no biopsy-related complications. Conclusion: CT-guided percutaneous core-needle biopsy of the omentum is a safe, useful and highly accurate procedure for diagnosing malignant omental pathology. (orig.)

  2. Usefulness of US-guided automated gun biopsy of nonpalpable breast lesions

    Energy Technology Data Exchange (ETDEWEB)

    Kwak, Min Sook; Kim, Hak Soo; Lee, Han Kyung; Koh, Sung Hye; O, Eun Young; Yoon, Myung Hwan; Yang, Dal Mo; Kim, Hyung Sik [Chungang Gil Hospital, Incheon (Korea, Republic of)

    1997-11-01

    To evaluate the clinical usefulness of ultrasonography(US)-guided automated gun biopsy of nonpalpable breast lesions. In 30 nonpalpable breast lesions over 0.6cm and detected on US, we performed US-guided biopsy using an 18-gauge automated biopsy gun. Two to four specimens were obtained from each lesion. We analyzed the site, size and depth of the lesions, and the length and histopathologic results of the specimens. In four lesions, surgical biopsy and gun biopsy results were compared. In 29 of 30 lesions(96.7%), specimens were adequate for histopathologic diagnosis, and this was as follows : one case of infiltrating ductal carcinoma, 13 of fibrocystic disease, 10 of fibrocystic disease versus fibroadenoma and one of fibrodenoma. There was also one reactive hyperplasia of LN, and one fatty one and two normal tissues, and in these four lesions, agreement between gun and surgical biopsy results was 100%. The only complication was minor bleeding, which was controlled by compression. US-guided automated gun biopsy is a clinically useful and safe procedure for evaluating nonpalpable breast lesions detected on US.

  3. Usefulness of US-guided automated gun biopsy of nonpalpable breast lesions

    International Nuclear Information System (INIS)

    Kwak, Min Sook; Kim, Hak Soo; Lee, Han Kyung; Koh, Sung Hye; O, Eun Young; Yoon, Myung Hwan; Yang, Dal Mo; Kim, Hyung Sik

    1997-01-01

    To evaluate the clinical usefulness of ultrasonography(US)-guided automated gun biopsy of nonpalpable breast lesions. In 30 nonpalpable breast lesions over 0.6cm and detected on US, we performed US-guided biopsy using an 18-gauge automated biopsy gun. Two to four specimens were obtained from each lesion. We analyzed the site, size and depth of the lesions, and the length and histopathologic results of the specimens. In four lesions, surgical biopsy and gun biopsy results were compared. In 29 of 30 lesions(96.7%), specimens were adequate for histopathologic diagnosis, and this was as follows : one case of infiltrating ductal carcinoma, 13 of fibrocystic disease, 10 of fibrocystic disease versus fibroadenoma and one of fibrodenoma. There was also one reactive hyperplasia of LN, and one fatty one and two normal tissues, and in these four lesions, agreement between gun and surgical biopsy results was 100%. The only complication was minor bleeding, which was controlled by compression. US-guided automated gun biopsy is a clinically useful and safe procedure for evaluating nonpalpable breast lesions detected on US

  4. Biopsy in Musculoskeletal Tumors

    Directory of Open Access Journals (Sweden)

    Mohammad Gharehdaghi

    2014-09-01

    proximity to the skin incision, because this tract is also contaminated and must be excised with the surgical specimen. Imaging-guided core needle biopsy is a well-established technique for the diagnosis of bone and soft tissue tumors and tumor-like lesions in specialized orthopedic oncology centers. Although large lesions of the limbs can easily be biopsied without image guidance, lesions in the spine, para spinal area, and pelvis are difficult to target, therefore taking the advantage of C.T. guidance will improve the accuracy of targeting the lesion for biopsy purposes. We can benefit from image intensifiers for targeting limb lesions rather than C.T. guidance. Also sonographic guide can be applied for soft tissue lesions (Figure D, E, F. In soft tissue tumors, the results of percutaneous CNB are relatively inferior compared to open biopsy whereas almost equal results are expected for bony tumors except for low-grade chondrosarcoma. CNB is a safe, minimally invasive, and cost effective technique for the diagnosis of bone lesions if done by an experienced orthopedic oncologic surgeon and be evaluated by an experienced anatomical bone pathologist (1, 3. For soft tissue tumors, CNB results depend on the size of the lesion, its location and amount of tumor necrosis. Guided needle biopsy have become the standard technique in most orthopedic oncologic centers. The accuracy of this method in our center is more than 90% for bone tumors. Cores should be taken in different directions including areas of central necrotic tissues but from a single well planned entrance. The procedure is quick, especially for bone CNB or soft tissue FNA and CNB, and the diagnosis can be achieved within 24 – 48 hours. The material should be sufficient for immunohistochemistry evaluations as well (1-3. Because I have seen 3 cases of tumor implantation at the towel clips puncture site including 2 chondrosarcomas and a case of malignant schowanoma, so I highly suggest that never crush the skin by towel

  5. Liver Biopsy

    Science.gov (United States)

    ... instrument called a cannula to remove the liver tissue sample. What is the liver and what does it do? ... who specializes in diagnosing diseases—looks at the tissue with a microscope and sends a report to the person's health care provider. What are the risks of liver biopsy? The risks ...

  6. Diagnostic value of polymerase chain reaction analysis of skin biopsies in purpura fulminans.

    Science.gov (United States)

    Beau, Caroline; Vlassova, Natalia; Sarlangue, Jean; Brissaud, Olivier; Léauté-Labrèze, Christine; Boralevi, Franck

    2013-01-01

    Even though prompt diagnosis and treatment of purpura fulminans (PF) is essential to reduce mortality, early administration of antibiotics may preclude identification of the causative agent by standard bacterial cultures and thus render definitive diagnosis impossible. Here we present a case of an infant with PF and negative bacterial cultures for whom polymerase chain reaction (PCR) analysis of a cutaneous biopsy specimen obtained 4 days after initiation of antibiotics identified the genomic sequence of Neisseria meningitidis genogroup C. When bacterial cultures fail to provide useful information, PCR of skin biopsy specimens can be a valuable diagnostic tool in PF. © 2013 Wiley Periodicals, Inc.

  7. Prostate biopsy: indications and technique.

    Science.gov (United States)

    Matlaga, Brian R; Eskew, L Andrew; McCullough, David L

    2003-01-01

    The last decade has seen numerous modifications in the way prostate cancer is diagnosed. We review the current indications for and methods of prostate biopsy. The English language literature was reviewed regarding major indications for and methods of prostate biopsy. Pertinent peer reviewed articles were collated and analyzed. The most widely accepted indication for prostate biopsy is a prostate specific antigen (PSA) value of greater than 4.0 ng./ml. However, some investigators advocate prostate biopsy for men with a PSA value in the 2.5 to 4.0 ng./ml. range, believing that use of this parameter results in detection of a greater number of cases of curable disease. Age specific PSA range, percent free PSA and presence of prostatic intraepithelial neoplasia or atypia are all considered to be relative indications for prostate biopsy. The current literature describes a trend toward increasing the number of cores obtained and the sites biopsied beyond those of the standard sextant technique. The additional cores in many series are obtained from more lateral regions of the gland. Although several criteria are used as indications for initial prostate biopsy, all are based on PSA level and/or abnormal digital rectal examination. Future improvements in currently used prostate cancer markers may result in better selection of cases to biopsy. There is no universally accepted technique of prostate gland biopsy. The current literature supports use of more extensive biopsy techniques to increase the likelihood of prostate cancer detection.

  8. No need for biopsies

    DEFF Research Database (Denmark)

    Gjødsbøl, Kristine; Skindersoe, Mette E; Christensen, Jens Jørgen

    2011-01-01

    collected. After 4 weeks, additional biopsy and filter paper pad samples were collected. Bacteria were isolated and identified at species level by standard methods. The most common bacterial species detected was Staphylococcus aureus found in 89% of the ulcers. No methicillin-resistant S. aureus isolates...... were found. We did not find any significant differences regarding the bacterial species isolated between the three sampling techniques. However, using multiple techniques led to identification of more species. Our study suggests that it is sufficient to use swab specimens to identify the bacterial...

  9. Small airways dysfunction and neutrophilic inflammation in bronchial biopsies and BAL in COPD

    NARCIS (Netherlands)

    Lapperre, Thérèse S.; Willems, Luuk N. A.; Timens, Wim; Rabe, Klaus F.; Hiemstra, Pieter S.; Postma, Dirkje S.; Sterk, Peter J.

    2007-01-01

    BACKGROUND: The single-breath N(2) test (sbN(2)-test) is closely related to small airways pathology in resected lung specimens of smokers. We investigated whether uneven ventilation and airway closure are associated with specific markers of airway inflammation as obtained by bronchial biopsies, BAL,

  10. Small airways dysfunction and neutrophilic inflammation in bronchial biopsies and BAL in COPD

    NARCIS (Netherlands)

    Lapperre, Therese S.; Willems, Luuk N. A.; Timens, Wim; Rabe, Klaus F.; Hiemstra, Pieter S.; Postma, Dirkje S.; Sterk, Peter J.

    Background: The single-breath N-2 test (sbN(2)-test) is closely related to small airways pathology in resected lung specimens of smokers. We investigated whether uneven ventilation and airway closure are associated with specific markers of airway inflammation as obtained by bronchial biopsies, BAIL,

  11. morphological pattern of endometrial biopsies in south

    African Journals Online (AJOL)

    INTRODUCTION. Endometrial biopsies are among the most common specimens submitted for histopathological analysis.1. Endometrial biopsy is a safe, efficient and cost-effective means of evaluating the uterine endometrium. The procedure is usually associated with minimal discomfort and is easily accomplished in the ...

  12. 'Microerosions' in rectal biopsies in Crohn's disease

    DEFF Research Database (Denmark)

    Poulsen, Steen Seier

    1984-01-01

    Small (less than 1 mm), superficial erosions ('microerosions') have been observed stereo-microscopically in surface-stained rectal biopsies in Crohn's disease (CD). Biopsy specimens from 97 patients with CD, 225 with ulcerative colitis (UC), and a control material of 161 patients were investigated...

  13. Diagnostic performance of imaging-guided core needle biopsy of the mesentery and peritoneum.

    Science.gov (United States)

    Pérez Montilla, M E; Lombardo Galera, S; Espejo Herrero, J J; Sastoque, J M; Zurera Tendero, L

    2018-01-21

    To evaluate the diagnostic performance of imaging-guided core needle biopsy of nodules and diffuse infiltration of the omentum or of the peritoneum. We retrospectively evaluated 57 patients who underwent core needle biopsy of the peritoneum or of the omentum between March 2014 and January 2017. We used computed tomography (CT) to plan the biopsy. Biopsies were guided by CT or ultrasonography (US). We classified the results as diagnostic (benign / malignant) or inconclusive (inadequate sample). We calculated the sensitivity, specificity, positive-predictive value, and negative predictive value. We analyzed whether the specimen was diagnostic depending on the imaging technique used (CT or US) and on the type of omental or peritoneal involvement from which the specimen was obtained (mass, nodule, or diffuse involvement). All (100%) the percutaneous biopsies were diagnostic. The sensitivity of the technique was 98.18% and the specificity was 100%. The positive predictive value was 100% and the negative predictive value was 50%. Both the specimens obtained under CT guidance (n=10) and those obtained under US guidance (n=47) were diagnostic. Likewise, biopsies of masses (n=24), of nodules (n=17), and even of diffuse infiltration (n=16) of the peritoneum or omentum enabled the histologic diagnosis. The rate of complications was 1.75% (one death). Percutaneous core needle biopsy has high sensitivity regardless of the imaging technique used to guide the technique (CT or US) and of the type of lesion biopsied (mass, nodule, diffuse infiltration). It is a useful technique with a very low rate of complications, although severe complications can occur. Copyright © 2018 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.

  14. A randomized trial to determine the diagnostic accuracy of conventional vs. jumbo forceps biopsy of gastric epithelial neoplasias before endoscopic submucosal dissection; open-label study.

    Science.gov (United States)

    Jeon, Hyo Keun; Ryu, Ho Yoel; Cho, Mee Yon; Kim, Hyun-Soo; Kim, Jae Woo; Park, Hong Jun; Kim, Moon Young; Baik, Soon Koo; Kwon, Sang Ok; Park, Su Yeon; Won, Sung Ho

    2014-10-01

    Larger biopsy specimens or increasing the number of biopsies may improve the diagnostic accuracy of gastric epithelial neoplasia (GEN). The aims of this study was to compare the diagnostic accuracies between conventional and jumbo forceps biopsy of GEN before endoscopic submucosal dissection (ESD) and to confirm that increasing the number of biopsies is useful for the diagnosis of GEN. The concordance rate between EFB and ESD specimens was not significantly different between the two groups [83.1 % (54/65) in JG vs. 79.1 % (53/67) in CG]. On multivariate analyses, two or four EFBs significantly increased the cumulating concordance rate [coefficients; twice: 5.1 (P = 0.01), four times: 5.9 (P = 0.02)]. But, the concordance rate was decreased in high grade dysplasia (coefficient -40.32, P = 0.006). One hundred and sixty GENs from 148 patients were randomized into two groups and finally 67 GENs in 61 patients and 65 GENs in 63 patients were allocated to the conventional group (CG) or jumbo group (JG), respectively. Four endoscopic forceps biopsy (EFB) specimens were obtained from each lesion with conventional (6.8 mm) forceps or jumbo (8 mm) forceps. The histological concordance rate between 4 EFB specimens and ESD specimens was investigated in the two groups. Before ESD, the diagnostic accuracy of GENs was significantly increased not by the use of jumbo forceps biopsy but by increasing the number of biopsies.

  15. PET-guided breast biopsy.

    Science.gov (United States)

    Kalinyak, Judith E; Schilling, Kathy; Berg, Wendie A; Narayanan, Deepa; Mayberry, Jennifer P; Rai, Rajesh; Dupree, Elizabeth B; Shusterman, Denise K; Gittleman, Mark A; Luo, Weidong; Matthews, Chris G

    2011-01-01

    Molecular imaging, using positron emission tomography (PET), has become an integral step in the evaluation of many patients with malignancy. However, its use in patients with breast cancer has been limited by the lower levels of (18) F-fluorodeoxyglucose (FDG) uptake in some breast malignancies compared to other cancers, the small size of many breast cancers, and the need for biopsy under PET guidance. High-resolution breast PET, or positron emission mammography (PEM), with biopsy guidance software, now addresses these issues. We report a prospective, multicenter study designed to test the efficacy and safety of PEM biopsy guidance software in women with FDG-avid breast lesions worrisome for malignancy. The intervention chosen was vacuum-assisted core biopsy. Nineteen subjects underwent a total of 24 PEM-guided biopsies. All lesions were successfully targeted and sampled as determined by post-biopsy image scan evaluation, specimen imaging, and pathologic concordance. Invasive cancer was identified in 13 of 24 lesions (54%), while four (17%) were high-risk lesions and three of these were upgraded to malignancy at excision. No serious adverse events occurred and all patients found the procedure to cause only minimal to mild discomfort. High-resolution PEM-guided breast biopsy is both safe and effective for the sampling of PET-depicted breast lesions. © 2011 Wiley Periodicals, Inc.

  16. Ultrasound-guided percutaneous biopsy of digestive tract lesions

    International Nuclear Information System (INIS)

    Gil, S.; Martin, I.; Ballesteros, J. M.; Gomez, C.; Marco, S. F.; Fernandez, P.

    1999-01-01

    To present our experience in ultrasound-guided percutaneous biopsy of lesions located in the digestive tract. We performed ultrasound-guided percutaneous biopsy in 14 patients (10 men and 4 women) ranging in age from 7 to 71 years (mean; 519 years). The lesions were located throughout the digestive tract, from the pyriform sinus to the sigmoid colon. The biopsy was carried out with a 5 MHz convex probe equipped with a device to direct the needle. An 18G automatic needle or a 20G Chiba needle was used to obtain specimens for histological study in every case, and additional samples were collected with a 22G needle for cytological examination in 13 of the patients. The ultrasound images corresponded to pseudokidney in 9 cases and extrinsic masses in 5. The diagnosis was obtained from the histological examination in every case (100%) and from cytology in 6 (44.4%), the latter results were less specific. The only complication corresponded to a case of bilioperitoneum. Ultrasound-guided percutaneous biopsy is a suitable technique for the histological diagnosis of those lesions of the digestive tract that are visible in ultrasound images, but that for some reason can not be examined by endoscopic biopsy. (Author) 20 refs

  17. Receptor Binding Sites for Substance P, but not Substance K or Neuromedin K, are Expressed in High Concentrations by Arterioles, Venules, and Lymph Nodules in Surgical Specimens Obtained from Patients with Ulcerative Colitis and Crohn Disease

    Science.gov (United States)

    Mantyh, Christopher R.; Gates, Troy S.; Zimmerman, Robert P.; Welton, Mark L.; Passaro, Edward P.; Vigna, Steven R.; Maggio, John E.; Kruger, Lawrence; Mantyh, Patrick W.

    1988-05-01

    Several lines of evidence indicate that tachykinin neuropeptides [substance P (SP), substance K (SK), and neuromedin K (NK)] play a role in regulating the inflammatory and immune responses. To test this hypothesis in a human inflammatory disease, quantitative receptor autoradiography was used to examine possible abnormalities in tachykinin binding sites in surgical specimens from patients with inflammatory bowel disease. Surgical specimens of colon were obtained from patients with ulcerative colitis (n = 4) and Crohn disease (n = 4). Normal tissue was obtained from uninvolved areas of extensive resections for carcinoma (n = 6). In all cases, specimens were obtained <5 min after removal to minimize influences associated with degradation artifacts and were processed for quantitative receptor autoradiography by using 125I-labeled Bolton--Hunter conjugates of NK, SK, and SP. In the normal colon a low concentration of SP receptor binding sites is expressed by submucosal arterioles and venules and a moderate concentration is expressed by the external circular muscle, whereas SK receptor binding sites are expressed in low concentrations by the external circular and longitudinal muscle. In contrast, specific NK binding sites were not observed in any area of the human colon. In colon tissue obtained from ulcerative colitis and Crohn disease patients, however, very high concentrations of SP receptor binding sites are expressed by arterioles and venules located in the submucosa, muscularis mucosa, external circular muscle, external longitudinal muscle, and serosa. In addition, very high concentrations of SP receptor binding sites are expressed within the germinal center of lymph nodules, whereas the concentrations of SP and SK binding sites expressed by the external muscle layers are not altered significantly. These results demonstrate that receptor binding sites for SP, but not SK or NK, are ectopically expressed in high concentrations (1000-2000 times normal) by cells

  18. Semi-Nested Real-Time Reverse Transcription Polymerase Chain Reaction Methods for the Successful Quantitation of Cytokeratin mRNA Expression Levels for the Subtyping of Non-Small-Cell Lung Carcinoma Using Paraffin-Embedded and Microdissected Lung Biopsy Specimens

    International Nuclear Information System (INIS)

    Nakanishi, Yoko; Shimizu, Tetsuo; Tsujino, Ichiro; Obana, Yukari; Seki, Toshimi; Fuchinoue, Fumi; Ohni, Sumie; Oinuma, Toshinori; Kusumi, Yoshiaki; Yamada, Tsutomu; Takahashi, Noriaki; Hashimoto, Shu; Nemoto, Norimichi

    2013-01-01

    In patients with inoperable advanced non-small cell lung carcinomas (NSCLCs), histological subtyping using small-mount biopsy specimens was often required to decide the indications for drug treatment. The aim of this study was to assess the utility of highly sensitive mRNA quantitation for the subtyping of advanced NSCLC using small formalin fixing and paraffin embedding (FFPE) biopsy samples. Cytokeratin (CK) 6, CK7, CK14, CK18, and thyroid transcription factor (TTF)-1 mRNA expression levels were measured using semi-nested real-time quantitative (snq) reverse-transcribed polymerase chain reaction (RT-PCR) in microdissected tumor cells collected from 52 lung biopsies. Our results using the present snqRT-PCR method showed an improvement in mRNA quantitation from small FFPE samples, and the mRNA expression level using snqRT-PCR was correlated with the immunohistochemical protein expression level. CK7, CK18, and TTF-1 mRNA were expressed at significantly higher levels (P<0.05) in adenocarcinoma (AD) than in squamous cell carcinoma (SQ), while CK6 and CK14 mRNA expression was significantly higher (P<0.05) in SQ than in AD. Each histology-specific CK, particularly CK18 in AD and CK6 in SQ, were shown to be correlated with a poor prognosis (P=0.02, 0.02, respectively). Our results demonstrated that a quantitative CK subtype mRNA analysis from lung biopsy samples can be useful for predicting the histology subtype and prognosis of advanced NSCLC

  19. Histological Diagnosis of Oral Lesions with Cutting Needle Biopsy: a Pilot Study

    Directory of Open Access Journals (Sweden)

    José Antonio Rossi dos Santos

    2011-04-01

    Full Text Available Objectives: The aim of this pilot study was to evaluate the effectiveness of cutting needle biopsy in the diagnosis of solid oral lesions.Material and Methods: The biopsies were carried out on seven patients who presented with solid oral lesions with sizes ranging from 2 to 6 cm. Specimens were obtained from each lesion before conventional biopsies using a cutting needle with 18-gauge x 9 cm (MD TECH, Gainesville, FL, USA. A total of 64 specimens processed by hematoxylin-eosin staining method, were obtained. Afterwards, the analysis was performed by an oral pathologist, in two different stages, with and without the clinical history of each lesion. Then, these answers were compared with the final histological diagnosis.Results: Results presented by the descriptive analysis showed that the correct diagnosis using cutting needle biopsy without the clinical history of lesions was registered in 37.5% of cases, while with the clinical history in 76.6%.Conclusions: Despite the promising results as a potential technique for biopsies and histological diagnosis of oral lesions, the cutting needle biopsy should be analyzed carefully in those cases.

  20. Prostate cancer diagnostics with biopsy material

    Directory of Open Access Journals (Sweden)

    Fedorina Т.A.

    2013-12-01

    Full Text Available The aim of the article is to study the potential importance of specific location of biopsy of prostate cancer. Material and methods. Histological material from 700 patients has been examinated. 580 specimen of radical prostatectomy were examined. TRUS-guided 12-cores biopsy has been performed in all patients. Histological, computer morphomet-ric, immunohistochemal methods (PIN4-coctail, AR were used. Results. It has been established that undergrading of carcinoma in needle biopsy occurred in 26% of patients. Overgrading of carcinoma in needle biopsy may also occur, but it was only found in 3% of cases. Undergrading results have been explained by low amount of tumor elements taken from tiny areas of carcinoma, multicentric growth and heterogenous structure of tumor. Conclusions. An important task is to identify the minimal or limited adenocarcinoma in biopsies, as tumor of >1cc volume is often found in prostatectomy specimen.

  1. Transjugular Renal Biopsy: Our Experience and Technical Considerations

    International Nuclear Information System (INIS)

    See, Teik Choon; Thompson, Barbara C.; Howie, Alexander J.; Karamshi, M.; Papadopoulou, Anthie M.; Davies, Neil; Tibballs, Jonathan

    2008-01-01

    The purpose of this study was to describe the indications for and technique of transjugular renal biopsy (TJRB) and evaluate the efficacy and complications of this method. We performed a retrospective review of 59 patients who underwent TJRB using the Quick-core needle biopsy system (Cook, Letchworth, UK) over a 4-year period. The indications for obtaining renal biopsy included acute renal failure, chronic renal failure, nephrotic syndrome, and proteinuria with or without other associated disease. Indications for the transjugular approach included coagulopathy, biopsy of a solitary kidney or essentially single functioning kidney, simultaneous renal and hepatic biopsy, morbid obesity, and failed percutaneous biopsy. All but four cases were performed via the right internal jugular vein. The right, left, or both renal veins were cannulated in 41, 14, and 4 cases, respectively. Combined liver and renal biopsies were obtained in seven cases. Diagnostic biopsy specimens were obtained in 56 of 59 patients (95%). The number and size of tissue cores ranged from 1 to 9 mm and from 1 to 20 mm, respectively. The mean numbers of glomeruli per procedure on light microscopy and electron microscopy were 10.3 and 2.6, respectively. Specimens for immunohistology were acquired in 49 cases, of which 40 were adequate. Of the 56 successful TJRB procedures, 34 (61%) were associated with isolated capsular perforation (19), contained subcapsular leak (10), isolated collecting system puncture (1), and concurrent collecting system and capsular perforation (4). There was a significant increase in capsular perforation with six or more needle passes, although no significant correlation was seen between number of needle passes and complication. Six patients had minor complications defined as hematuria or loin pain. Seven patients developed major complications, of whom five received blood transfusion alone. Two required intervention: in one an arteriocalyceal fistula was embolized and the patient

  2. Evaluation of EGFR mutation status in cytology specimens: an institutional experience.

    Science.gov (United States)

    Aisner, D L; Deshpande, C; Baloch, Z; Watt, C D; Litzky, L A; Malhotra, B; Sepulveda, A R; Langer, C; Evans, T; Van Deerlin, V M

    2013-04-01

    Epidermal growth factor receptor (EGFR) mutation status has been shown to predict response to anti-EGFR tyrosine kinase inhibitors in non-small cell lung cancer (NSCLC). In patients with advanced-stage NSCLC, evaluation of mutational status is increasingly requested on biopsy or fine-needle aspiration specimens, which often have limited material. There are limited data on the suitability of cytology cell blocks (CB) for EGFR mutation testing. In this study, we report our institutional experience with cytology cell block material for EGFR mutation testing. We retrospectively reviewed EGFR mutation analyses performed on 234 surgical (SP) and cytology (CB) from October 2007 to May 2010. One hundred ninety-two SP specimens and 42 CB specimens were evaluated for EGFR mutation. CB specimens were evaluated for overall specimen size based on aggregate cellularity in comparison to small biopsy specimens, and percent tumor. Of the 192 SP and 42 CB specimens, 31 (16.1%) and 11 (26.2%) were positive for EGFR mutation, respectively; there does not appear to be an association between mutation detection rate and the source of the specimen (P = 0.124). Limited DNA was obtained from 70.0% (29/42), including 81.8% (9/11) of those which were mutation positive. Additionally, 45.4% (5/11) of mutation positive specimens had extremely low DNA yields. Although 16.6% (7/42) of CB specimens had 10% tumor. These data indicate that CB specimens provide an alternative source for molecular evaluation of NSCLC, and that tumor percentage may be more important than specimen size and/or DNA yield in determining the suitability of these specimens for testing. Copyright © 2011 Wiley Periodicals, Inc.

  3. Current status of core needle biopsy of the thyroid

    Energy Technology Data Exchange (ETDEWEB)

    Baek, Jung Hwan [Dept. of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of)

    2017-04-15

    Thyroid nodules are a common clinical problem. Fine-needle aspiration (FNA) and large-needle biopsy have been used to diagnose thyroid nodules. Before the 1980s, large-needle biopsy was the standard procedure for the thyroid, but FNA became the standard diagnostic tool in the 1980s because it is a safe procedure that leads to accurate diagnoses. With advances in core needle biopsy (CNB) devices (i.e., spring-activated core needles) and development of high-resolution ultrasound, it has become possible to make accurate diagnoses while minimizing complications. Although 18- to 21-gauge core needles can be used to biopsy thyroid nodules, 18-gauge needles are most commonly used in Korea. The relationships among the size of the needle, the number of core specimens, and diagnostic accuracy have not yet been conclusively established, but the general tendency is that thinner needles cause less damage to the normal thyroid, but allow a smaller amount of thyroid tissue to be biopsied to be obtained. These relationships may be validated in the future.

  4. Comparison of CT and PET/CT for biopsy guidance in oncological patients

    Energy Technology Data Exchange (ETDEWEB)

    Cerci, Juliano J.; Bogoni, Mateos; Cunha Pereira, Carlos; Cerci, Rodrigo J.; Krauzer, Cassiano; Vicente Vitola, Joao [Quanta - Diagnostico e Terapia, Curitiba, PR (Brazil); Tabacchi, Elena; Fanti, Stefano [University Hospital S. Orsola-Malpighi, Nuclear Medicine Department, Bologna (Italy); Delbeke, Dominique [Vanderbilt University, Nashville, TN (United States); Giacometti Sakamoto, Danielle [Byori - Laboratorio de Patologia, Curitiba (Brazil)

    2017-08-15

    lesions. This prospective analysis of a large number of patients demonstrated the feasibility and advantages of using PET/CT as the imaging method of choice for biopsy guidance, especially where FDG-avid foci do not show corresponding lesions on the CT scan. There were no significant differences in the ability to obtain a diagnostic specimen or in the complication rates between PET/CT and CT guidance. (orig.)

  5. Stereotactic biopsy

    International Nuclear Information System (INIS)

    Mwangi, M.N.; Handa, A.

    2006-01-01

    This technology is capable of locating lesions precise detected by the mammography examinations. This devise allows the surgeon to position automatically the needle to perform the cytological/histological biopsy with maximum position accuracy. This is under sterile procedure. to position the lesion in the beam, two radiographic procedures are carried out: the first with the X-ray beam at an inclination of -15 degrees with respect to the position 0 degrees and the second at the inclination +15 degrees. After processing the film the lesion will appear on both radiographs but on light are of the negatoscope. With the cursor information is fed from four points. On the display the length of the needle will appear immediately. The length of the needle to be used in suction is chosen on the basis of the two values on the display. This information fed on the control panel will move the needle unit position where the lesion is. the needle is then introduced under local anaesthesia at the preselected length until it clicks into position. An exposure is made with needle in situ in position at +15 degrees and -15 degrees to ensure the needle is in position. the suction is then carried out and the needle removed. The machine is then reset to return at the initial position

  6. Screen-film specimen radiography

    International Nuclear Information System (INIS)

    Shepard, S.J.; Hogan, J.; Schreck, B.

    1990-01-01

    This paper reports on the reproducibility and quality of biopsy specimen radiographs, a unique phototimed cabinet x-ray system is being developed. The system utilizes specially modified Kodal Min-R cassettes and will be compatible with current mammographic films. Tube voltages are in the 14-20-kVp range with 0.1-1.0-second exposure times. A top-hat type compression device is used (1) to compress the specimen to uniform thickness, (2) to measure the specimen thickness and determine optimum kVp, and (3) to superimpose a grid over the specimen for identification of objects of radiographic interest. The phototiming circuit developed specifically for this purpose will be described along with the modified Min-R cassette. Characteristics of the generator and cabinet will also be described. Tests will be performed on phantoms to evaluate the system limitations

  7. Biopsy system for CT-guided biopsies

    International Nuclear Information System (INIS)

    Onik, G.; Cosman, E.; Wells, T.; Goldberg, H.I.; Moss, A.; Costello, P.; Kane, R.

    1987-01-01

    CT stereotaxic brain biopsies have made brain biopsies safe and minimally invasive. CT-guided biopsies of the body, however, have traditionally used a hand-guidance method. CT biopsy guidance systems for the body have recently become available that have similar capabilities as those of brain biopsy systems. To compare the clinical utility of stereotaxically guided biopsies with hand-guided biopsies, the authors prospectively compared 40 biopsies performed with each method. In the stereotaxic method, a localizor grid was placed on the patient to define a reference point, and a frame was used to guide the needle along the intended path. Computer software programs calculated complex paths from one scan plane to another. Although the results disclosed no significant differences in lesion size or path length between the two groups, the stereotaxically guided biopsies required 75% fewer needle manipulations to hit the intended target. Consequently, the stereotaxically guided biopsies required 40% less time and 80% fewer localization scans to find the biopsy needle than did the hand-guided biopsies

  8. Predictors of prostate cancer in ultrasound-guided transperineal saturation biopsy in Turkish men with multiple prior negative biopsies.

    Science.gov (United States)

    Yazici, Sertac; Kiziloz, Halil; Bozaci, Ali Cansu; Baydar, Dilek Ertoy; Del Biondo, Dario; Ozen, Haluk

    2016-05-24

    Transperineal prostate biopsy (STPB) is associated with an improved cancer detection rate and an increase in anterior and apical prostate cancers compared to standard transrectal biopsy. A total of 48 men with at least two sets of prior prostate biopsies underwent transrectal ultrasound-guided STPB. Prostate rebiopsy indications were serum prostate-specific antigen (PSA) levels greater than 2.5 ng/mL and/or abnormal digital rectal examination and/or presence of high-grade prostatic intraepithelial neoplasia (HGPIN; ≥2 cores) or atypical small acinar proliferation (ASAP) at previous biopsies. The procedure was performed at dorsal lithotomy position under general anesthesia using a perineal 0.5 cm brachytherapy template attached to the transrectal ultrasound probe. Specimens from each zone were sent separately for pathological examination. Mean PSA level at STPB was 15.9 ng/mL (range 4.03 to 59.57). An average of 54.5 cores was obtained. Prostate adenocarcinoma was detected in 15 of 48 (31%) patients. Mean percentage of malignant cores was 11.9%. Multivariate logistic regression analysis revealed that age and presence of ASAP or HGPIN at previous biopsies were independent predictors of prostate cancer (p<0.05). No major complications, including sepsis and severe urinary or rectal bleeding, were observed in any of the patients. Five patients (10%) developed acute urinary retention after the procedure requiring urethral catheterization. Considerable number of patients with negative multiple biopsies were diagnosed with prostate cancer. STPB is a well-tolerated procedure with minimal morbidity, which can be considered for the diagnosis of prostate cancer in patients with previous negative biopsies.

  9. Fracture toughness of thin specimen

    International Nuclear Information System (INIS)

    Machida, Kenji; Kikuchi, Masanori; Miyamoto, Hiroshi

    1991-01-01

    Three-dimensional elastic-plastic analyses were carried out on 1 and 2 mm-thick CCT specimens with or without side grooves. The valid effective thickness, 0.85 √(B o xB n ), was obtained from the 3-D analyses. The stretched-zone method is better than the R-curve method to determine the J in value of the thin specimen. However, a great many data should be gathered near the J in value. The J in value obtained using side-grooved specimens is always lower than that of non-side-grooved specimens. Considering the difficulty of machining the side groove, the side groove is not appropriate for the thin specimen. As the thickness decreases, the J in value decreases. However, it is possible to estimate the J ic value from the J in value obtained using thin CCT specimens. (author)

  10. Sampling variability of percutaneous liver biopsy in primary sclerosing cholangitis.

    Science.gov (United States)

    Olsson, R; Hägerstrand, I; Broomé, U; Danielsson, A; Järnerot, G; Lööf, L; Prytz, H; Rydén, B O; Wallerstedt, S

    1995-01-01

    AIMS--To study sampling variability of percutaneous liver biopsy in primary sclerosing cholangitis (PSC). METHODS--One hundred and twelve biopsy specimens (that is, 56 pairs) from 44 patients with PSC, confirmed by cholangiography, were evaluated blindly. Six different features, qualitative grading of four other features and staging according to Ludwig were assessed. RESULTS--Quantitative sampling variability was confined mainly to just one grade or stage, although 11% (six of 56) of the biopsy specimen pairs differed by more than one stage (7% (one of 15) in pairs > 2 cm in length). Qualitative sampling variabilities were between 18 and 71%. Advanced disease (stages 3 or 4) was missed in 40% (two of five) of the biopsy specimens while cirrhosis was missed in 37%. CONCLUSION--Paired liver biopsy specimens should be taken in clinical studies of PSC using liver histology for evaluation or prognosis. PMID:8537493

  11. Confounding factors in diagnostics of MGMT promoter methylation status in glioblastomas in stereotactic biopsies.

    Science.gov (United States)

    Weise, Lutz M; Harter, Patrick N; Eibach, Sebastian; Braczynski, Anne K; Dunst, Maika; Rieger, Johannes; Bähr, Oliver; Hattingen, Elke; Steinbach, Joachim P; Plate, Karl H; Seifert, Volker; Mittelbronn, Michel

    2014-01-01

    In nonresectable glioblastoma (GBM), stereotactic biopsies are performed to retrieve tissue for diagnostic purposes. The analysis of O6-methylguanine-DNA methyltransferase (MGMT) promoter methylation adds prognostic and predictive information. The aim of the study was to detect confounding factors that limit the number of conclusive MGMT promoter methylation results. We analyzed 71 consecutive GBM patients undergoing stereotactic biopsy on whom MGMT analysis was performed by methylation-specific polymerase chain reaction. Specimens were correlated to imaging by coregistration and prospective documentation of biopsy localization. Our findings were validated in an additional 62 GBM stereotactic biopsies. Our results demonstrate that the best MGMT promoter methylation results were obtained from samples (n = 71) taken in a tangential manner from tumor areas showing contrast enhancement in magnetic resonance imaging. In the additional validation series of 62 stereotactically biopsied GBM, we were able to increase the rate of conclusive MGMT promoter methylation results from 76.1 to 85.48% by strictly planning the route of biopsy in a tangential manner if possible. These results underline that within the contrast-enhanced tumor part, choosing the trajectory in a tangential manner increases the diagnostic yield for conclusive MGMT promoter methylation analyses in stereotactic biopsies as a basis for patient stratification and individualized therapy.

  12. Ultrasound-guided percutaneous core needle biopsy of splenic lesions

    Energy Technology Data Exchange (ETDEWEB)

    Park, SangIk; Shin, Yong Moon; Won, Hyung Jin; Kim, Pyo Nyun; Lee, Moon Gyu [Dept. of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of)

    2017-05-15

    To evaluate the safety and efficacy of ultrasound-guided percutaneous core needle biopsy of splenic lesions. This retrospective study included 30 patients who underwent percutaneous core needle biopsy of their splenic lesions using 18- or 20-gauge needles between January 2001 and July 2016 in a single tertiary care center. The characteristics of the splenic lesions were determined by reviewing the ultrasound and computed tomography examinations. Acquisition rate and diagnostic accuracy were calculated, using pathologic results of the splenectomy specimen, clinical course and/or imaging follow-up as a reference standard. Post-procedure complications were identified from electronic medical records, laboratory findings and computed tomography images. Seventy-three specimens were obtained from the 30 patients and splenectomy was performed in 2 patients. Twenty-nine of the 30 patients had focal splenic lesions, while the remaining patient had homogeneous splenomegaly. Acquisition rate and diagnostic accuracy were 80.0% (24/30) and 76.7% (23/30), respectively. Perisplenic hemorrhage without hemodynamic instability developed in one patient. Ultrasound-guided percutaneous core needle biopsy of splenic lesions is a safe method for achieving a histopathologic diagnosis and can be considered as an alternative to splenectomy in patients with a high risk of splenectomy-related complications.

  13. Ultrasound-guided percutaneous core needle biopsy of splenic lesions

    International Nuclear Information System (INIS)

    Park, SangIk; Shin, Yong Moon; Won, Hyung Jin; Kim, Pyo Nyun; Lee, Moon Gyu

    2017-01-01

    To evaluate the safety and efficacy of ultrasound-guided percutaneous core needle biopsy of splenic lesions. This retrospective study included 30 patients who underwent percutaneous core needle biopsy of their splenic lesions using 18- or 20-gauge needles between January 2001 and July 2016 in a single tertiary care center. The characteristics of the splenic lesions were determined by reviewing the ultrasound and computed tomography examinations. Acquisition rate and diagnostic accuracy were calculated, using pathologic results of the splenectomy specimen, clinical course and/or imaging follow-up as a reference standard. Post-procedure complications were identified from electronic medical records, laboratory findings and computed tomography images. Seventy-three specimens were obtained from the 30 patients and splenectomy was performed in 2 patients. Twenty-nine of the 30 patients had focal splenic lesions, while the remaining patient had homogeneous splenomegaly. Acquisition rate and diagnostic accuracy were 80.0% (24/30) and 76.7% (23/30), respectively. Perisplenic hemorrhage without hemodynamic instability developed in one patient. Ultrasound-guided percutaneous core needle biopsy of splenic lesions is a safe method for achieving a histopathologic diagnosis and can be considered as an alternative to splenectomy in patients with a high risk of splenectomy-related complications

  14. The value of bladder mapping and prostatic urethra biopsies for detection of carcinoma in situ (CIS).

    Science.gov (United States)

    Gudjónsson, Sigurdur; Bläckberg, Mats; Chebil, Gunilla; Jahnson, Staffan; Olsson, Hans; Bendahl, Pär-Ola; Månsson, Wiking; Liedberg, Fredrik

    2012-07-01

    It is well known that CIS is a major risk factor for muscle-invasive bladder cancer and that this entity can be difficult to diagnose. Taking cold-cup mapping biopsies from different areas of the bladder (BMAP) is commonly used in patients at risk of harbouring CIS. The diagnostic accuracy of this approach has not been assessed until now. By using the CIS found in the cystoprostatectomy specimen as an indicator of the true occurrence of CIS and comparing that with the findings of BMAP, it is clear that the sensitivity of BMAP to detect CIS when present is low and that negative findings should be considered unreliable. To assess the value of bladder mapping and prostatic urethra biopsies for detection of urothelial carcinoma in situ (CIS). CIS of the urinary bladder is a flat high-grade lesion of the mucosa associated with a significant risk of progression to muscle-invasive disease. CIS is difficult to identify on cystoscopy, and definite diagnosis requires histopathology. Traditionally, if CIS is suspected, multiple cold-cup biopsies are taken from the bladder mucosa, and resection biopsies are obtained from the prostatic urethra in males. This approach is often called bladder mapping (BMAP). The accuracy of BMAP as a diagnostic tool is not known. Male patients with bladder cancer scheduled for cystectomy underwent cold-cup bladder biopsies (sidewalls, posterior wall, dome, trigone), and resection biopsies were taken from the prostatic urethra. After cystectomy, the surgical specimen was investigated in a standardised manner and subsequently compared with the BMAP biopsies for the presence of CIS. The histopathology reports of 162 patients were analysed. CIS was detected in 46% of the cystoprostatectomy specimens, and multiple (≥2) CIS lesions were found in 30%. BMAP (cold-cup bladder biopsies + resection biopsies from the prostatic urethra) provided sensitivity of 51% for any CIS, and 55% for multiple CIS lesions. The cold-cup biopsies for CIS in the bladder

  15. Ultrasound-guided percutaneous core needle biopsy of abdominal viscera: Tips to ensure safe and effective biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jin Woong; Shin, Sang Soo [Chonnam National University Hospital, Chonnam National University Medical School, Gwangju(Korea, Republic of)

    2017-04-15

    Ultrasound-guided percutaneous core needle biopsy (USPCB) is used extensively in daily clinical practice for the pathologic confirmation of both focal and diffuse diseases of the abdominal viscera. As a guidance tool, US has a number of clear advantages over computerized tomography or magnetic resonance imaging: fewer false-negative biopsies, lack of ionizing radiation, portability, relatively short procedure time, real-time intra-procedural visualization of the biopsy needle, ability to guide the procedure in almost any anatomic plane, and relatively lower cost. Notably, USPCB is widely used to retrieve tissue specimens in cases of hepatic lesions. However, general radiologists, particularly beginners, find USPCB difficult to perform in abdominal organs other than the liver; indeed, a full understanding of the entire USPCB process and specific considerations for specific abdominal organs is necessary to safely obtain adequate specimens. In this review, we discuss some points and techniques that need to be borne in mind to increase the chances of successful USPCB. We believe that the tips and considerations presented in this review will help radiologists perform USPCB to successfully retrieve target tissue from different organs with minimal complications.

  16. Telepathology and Optical Biopsy

    Directory of Open Access Journals (Sweden)

    Olga Ferrer-Roca

    2009-01-01

    Full Text Available The ability to obtain information about the structure of tissue without taking a sample for pathology has opened the way for new diagnostic techniques. The present paper reviews all currently available techniques capable of producing an optical biopsy, with or without morphological images. Most of these techniques are carried out by physicians who are not specialized in pathology and therefore not trained to interpret the results as a pathologist would. In these cases, the use of telepathology or distant consultation techniques is essential.

  17. Augmented reality visualization using image overlay technology for MR-guided interventions: cadaveric bone biopsy at 1.5 T.

    Science.gov (United States)

    Fritz, Jan; U-Thainual, Paweena; Ungi, Tamas; Flammang, Aaron J; McCarthy, Edward F; Fichtinger, Gabor; Iordachita, Iulian I; Carrino, John A

    2013-06-01

    The purpose of this study was to prospectively test the hypothesis that image overlay technology facilitates accurate navigation for magnetic resonance (MR)-guided osseous biopsy. A prototype augmented reality image overlay system was used in conjunction with a clinical 1.5-T MR imaging system. Osseous biopsy of a total of 16 lesions was planned in 4 human cadavers with osseous metastases. A loadable module of 3D Slicer open-source medical image analysis and visualization software was developed and used for display of MR images, lesion identification, planning of virtual biopsy paths, and navigation of drill placement. The osseous drill biopsy was performed by maneuvering the drill along the displayed MR image containing the virtual biopsy path into the target. The drill placement and the final drill position were monitored by intermittent MR imaging. Outcome variables included successful drill placement, number of intermittent MR imaging control steps, target error, number of performed passes and tissue sampling, time requirements, and pathological analysis of the obtained osseous core specimens including adequacy of specimens, presence of tumor cells, and degree of necrosis. A total of 16 osseous lesions were sampled with percutaneous osseous drill biopsy. Eight lesions were located in the osseous pelvis (8/16, 50%) and 8 (8/16, 50%) lesions were located in the thoracic and lumbar spine. Lesion size was 2.2 cm (1.1-3.5 cm). Four (2-8) MR imaging control steps were required. MR imaging demonstrated successful drill placement inside 16 of the 16 target lesions (100%). One needle pass was sufficient for accurate targeting of all lesions. One tissue sample was obtained in 8 of the 16 lesions (50%); 2, in 6 of the 16 lesions (38%); and 3, in 2 of the 16 lesions (12%). The target error was 4.3 mm (0.8-6.8 mm). Length of time required for biopsy of a single lesion was 38 minutes (20-55 minutes). Specimens of 15 of the 16 lesions (94%) were sufficient for pathological

  18. Comparison of the Diagnostic Yield of EUS Needles for Liver Biopsy: Ex Vivo Study.

    Science.gov (United States)

    Lee, Woo Jung; Uradomo, Lance T; Zhang, Yang; Twaddell, William; Darwin, Peter

    2017-01-01

    EUS-guided liver biopsy is an emerging method of liver tissue acquisition which is safe and had been shown to produce excellent histological yield. There is limited data comparing the diagnostic yield of different FNA needles. We aimed to compare the diagnostic performance of four commercially available 19-gauge FNA needles. Four FNA needles and one percutaneous needle were used to perform liver biopsies on two human cadaveric livers: Cook Echotip Procore™, Olympus EZ Shot 2™, Boston Scientific Expect Slimline™, Covidien SharkCore™, and an 18-gauge percutaneous needle (TruCore™, Argon Medical Devices). Each needle obtained biopsies by three, six, and nine complete back-and-forth motions of the needle ("throw") with a fanning technique. The combined lengths of specimen fragments and the total number of complete portal tracts (CPT) were measured by a blinded pathologist. One-way analysis of variance (ANOVA) and Bonferroni correction were used for statistical analysis. A total of 52 liver biopsies were performed. The Covidien SharkCore needle had significantly greater number of CPT compared to other FNA needles. The number of "throws" did not impact the number of CPT significantly. There was no statistically significant difference in mean total specimen length between each FNA needle type. The Covidien SharkCore needle produced superior histological specimen by capturing more CPT, possibly due to its unique needle design.

  19. Biopsy techniques for intraocular tumors

    Directory of Open Access Journals (Sweden)

    Pukhraj Rishi

    2016-01-01

    Full Text Available Biopsy involves the surgical removal of a tissue specimen for histopathologic evaluation. Most intraocular tumors are reliably diagnosed based on the clinical evaluation or with noninvasive diagnostic techniques. However, accurately diagnosing a small percentage of tumors can be challenging. A tissue biopsy is thus needed to establish a definitive diagnosis and plan the requisite treatment. From fine-needle aspiration biopsy (FNAB to surgical excision, all tissue collection techniques have been studied in the literature. Each technique has its indications and limitations. FNAB has been reported to provide for 88-95% reliable and safe ophthalmic tumor diagnosis and has gained popularity for prognostic purposes and providing eye conserving treatment surgeries. The technique and instrumentation for biopsy vary depending upon the tissue involved (retina, choroid, subretinal space, vitreous, and aqueous, suspected diagnosis, size, location, associated retinal detachment, and clarity of the media. The cytopathologist confers a very important role in diagnosis and their assistance plays a key role in managing and planning the treatment for malignancies.

  20. Obstructive jaundice: a comparative study of forceps and brush biopsy under percutaneous transhepatic cholangiography

    International Nuclear Information System (INIS)

    Li Yongdong; Han Xinwei; Wu Gang; Ma Bo; Xing Gusheng

    2004-01-01

    Objective: To compare the sensitivity between forceps biopsy and brushing, and to explore a feasible approach to pathological diagnosis of the obstructive jaundice. Methods: 92 consecutive patients with obstructive jaundice underwent transluminal forceps biopsy and brushing during percutaneous transhepatic cholangiography and percutaneous transhepatic cholangiodrainage. The technique was performed through a preexisting percutaneous transhepatic tract with multiple specimens obtained after passing the forceps biopsy or brush into a 8-French sheath. Finally the specimens were fixed with formalin for pathologic or cytologic diagnosis. Results: The histopathologic diagnosis was acquired in 81 out of 92 patients with forceps biopsy reaching the successful rate of 97.83%. Sensitivity of forceps biopsy in 92 patients was higher than that of brush in 84 patients (88.04% vs 76.19% χ 2 =4.251, P= <0.05). Conclusions: Percutaneous transhepatic cholangiobiopsy is a simple technique with minimal invasion, high sensitivity and worthy to be used spread extensively. Percutaneous transluminal brush cytology is also an useful method for establishing a diagnosis of cholangiocarcinoma. (authors)

  1. Microfabricated instrument for tissue biopsy and analysis

    Science.gov (United States)

    Krulevitch, Peter A.; Lee, Abraham P.; Northrup, M. Allen; Benett, William J.

    2001-01-01

    A microfabricated biopsy/histology instrument which has several advantages over the conventional procedures, including minimal specimen handling, smooth cutting edges with atomic sharpness capable of slicing very thin specimens (approximately 2 .mu.m or greater), micro-liter volumes of chemicals for treating the specimens, low cost, disposable, fabrication process which renders sterile parts, and ease of use. The cutter is a "cheese-grater" style design comprising a block or substrate of silicon and which uses anisotropic etching of the silicon to form extremely sharp and precise cutting edges. As a specimen is cut, it passes through the silicon cutter and lies flat on a piece of glass which is bonded to the cutter. Microchannels are etched into the glass or silicon substrates for delivering small volumes of chemicals for treating the specimen. After treatment, the specimens can be examined through the glass substrate.

  2. Hypoxia marker labeling in tumor biopsies: quantification of labeling variation and criteria for biopsy sectioning

    International Nuclear Information System (INIS)

    Thrall, Donald E.; Rosner, Gary L.; Azuma, Chieko; McEntee, Margaret C.; Raleigh, James A.

    1997-01-01

    Background and purpose: The error associated with using biopsy-based methods for assessing parameters reflective of the tumor microenvironment depends on the variability in distribution of the parameter throughout the tumor and the biopsy sample. Some attention has been given to intratumoral distribution of parameters, but little attention has been given to their intrabiopsy distribution. We evaluated the intrabiopsy distribution of CCI-103F, a 2-nitroimidazole hypoxia marker. Materials and methods: The hypoxia marker CCI-103F was studied in dogs bearing spontaneous solid tumors. Two biopsies were taken from each of seven tumors, for a total of 14 biopsies. Biopsies were serially sectioned and four to six contiguous slides from each 100-150 μm of the biopsy were used to formulate the best estimate of CCI-103F labeled area throughout the biopsy sample. One, two or four slides were then randomly selected from each biopsy and the labeled area, based on this limited sample, was compared to the estimate obtained from counting all available slides. Random sampling of slides was repeated 1000 times for each biopsy sample. Results: CCI-103F labeling variance throughout the biopsy decreased as the estimated overall labeled area in the biopsy decreased. The error associated with estimating the overall labeled area in a biopsy from a randomly selected subset of slides decreased as the number of slides increased, and as the overall labeled area in the biopsy decreased. No minimally labeled biopsy was classified as unlabeled based on limited sampling. Conclusion: With regard to CCI-103F labeling, quantification of the labeled area in four randomly selected slides from a biopsy can provide, in most biopsies, an estimate of the labeled area in the biopsy within an absolute range of ±0.05

  3. Biopsy - Multiple Languages

    Science.gov (United States)

    ... 简体中文) Expand Section Biopsy - 简体中文 (Chinese, Simplified (Mandarin dialect)) Bilingual PDF Health Information Translations Bone Marrow Biopsy - 简体中文 (Chinese, Simplified (Mandarin dialect)) ...

  4. Initial experience with a novel EUS-guided core biopsy needle (SharkCore): results of a large North American multicenter study

    Science.gov (United States)

    DiMaio, Christopher J.; Kolb, Jennifer M.; Benias, Petros C.; Shah, Hiral; Shah, Shashin; Haluszka, Oleh; Maranki, Jennifer; Sharzehi, Kaveh; Lam, Eric; Gordon, Stuart R.; Hyder, Sarah M.; Kaimakliotis, Pavlos Z.; Allaparthi, Satya B.; Gress, Frank G.; Sethi, Amrita; Shah, Ashish R.; Nieto, Jose; Kaul, Vivek; Kothari, Shivangi; Kothari, Truptesh H.; Ho, Sammy; Izzy, Manhal J.; Sharma, Neil R.; Watson, Rabindra R.; Muthusamy, V. Raman; Pleskow, Douglas K.; Berzin, Tyler M.; Sawhney, Mandeep; Aljahdi, Emad; Ryou, Marvin; Wong, Clarence K.; Gupta, Parantap; Yang, Dennis; Gonzalez, Susana; Adler, Douglas G.

    2016-01-01

    Background and aims: The ability to safely and effectively obtain sufficient tissue for pathologic evaluation by using endoscopic ultrasound (EUS) guidance remains a challenge. Novel designs in EUS needles may provide for improved ability to obtain such core biopsies. The aim of this study was to evaluate the diagnostic yield of core biopsy specimens obtained using a novel EUS needle specifically designed to obtain core biopsies. Patients and methods: Multicenter retrospective review of all EUS-guided fine-needle biopsies obtained using a novel biopsy needle (SharkCore FNB needle, Medtronic, Dublin, Ireland). Data regarding patient demographics, lesion type/location, technical parameters, and diagnostic yield was obtained. Results: A total of 250 lesions were biopsied in 226 patients (Median age 66 years; 113 (50 %) male). Median size of all lesions (mm): 26 (2 – 150). Overall, a cytologic diagnosis was rendered in 81 % specimens with a median number of 3 passes. When rapid onsite cytologic evaluation (ROSE) was used, cytologic diagnostic yield was 126/149 (85 %) with a median number of 3 passes; without ROSE, cytologic diagnostic yield was 31/45 (69 %, P = 0.03) with a median number of 3 passes. Overall, a pathologic diagnosis was rendered in 130/147 (88 %) specimens with a median number of 2 passes. Pathologic diagnostic yield for specific lesion types: pancreas 70/81 (86 %), subepithelial lesion 13/15 (87 %), lymph node 26/28 (93 %). Ten patients (10/226, 4 %) experienced adverse events: 4 acute pancreatitis, 5 pain, 1 fever/cholangitis. Conclusions: Initial experience with a novel EUS core biopsy needle demonstrates excellent pathologic diagnostic yield with a minimum number of passes. PMID:27652304

  5. Clinical application of CT-guided percutaneous puncturing biopsy of subcarinal lymph node

    International Nuclear Information System (INIS)

    Yuan Xiaodong; Wang Jianhua; Zuo Changjing; Tian Jianming

    2011-01-01

    Objective: To discuss the safety and clinical significance of CT-guided percutaneous puncturing biopsy of subcarinal lymph node. Methods: During the period of July 2006-July 2010, CT-guided percutaneous puncturing biopsy of subcarinal lymph node was carried out in 17 patients (11 males and 6 females, with an average age of 54 years) with enlarged subcarinal lymph nodes. The clinical data were retrospectively analyzed. Immediately after the puncturing procedure was completed, CT scanning was performed to observe if there any complications and to evaluate the safety of puncturing biopsy. Biopsy specimens were sent for pathological examination to assess the puncturing accuracy and to make the pathologic diagnosis. The clinical usefulness of this technique was evaluated. Results: Of the total 17 cases, successful puncturing into the enlarged subcarinal lymph nodes with single procedure was achieved in 14 and sufficient tissue sample was obtained. The biopsy failed in three cases at initial puncturing procedure as the needle could not be placed into the enlarged subcarinal lymph nodes, the puncturing biopsy had to given up in two patients because of hemoptysis and in another patient the second puncturing biopsy performed one week later was successful. The total technical successful rate was 88.2% (15/17). Of the fifteen cases with successful puncturing, definitive pathological diagnosis was obtained in 13 and the diagnosis was uncertain in the remaining two, with a diagnosis positive rate of 86.7% (13/15). Pathologically, the diagnoses included metastatic lymphadenopathy from lung cancer (n=10), proliferative inflammatory lymphadenopathy (n=2) and tuberculous enlargement of lymph nodes (n=1). Complications occurred in 4 patients (23.5%, 4/17), which mainly were pneumothorax and pulmonary hemorrhage. Conclusion: With high successful rate and diagnostic accuracy, CT-guided percutaneous puncturing biopsy of subcarinal lymph node is a safe and effective technique if the

  6. Preserved genetic diversity in organoids cultured from biopsies of human colorectal cancer metastases.

    Science.gov (United States)

    Weeber, Fleur; van de Wetering, Marc; Hoogstraat, Marlous; Dijkstra, Krijn K; Krijgsman, Oscar; Kuilman, Thomas; Gadellaa-van Hooijdonk, Christa G M; van der Velden, Daphne L; Peeper, Daniel S; Cuppen, Edwin P J G; Vries, Robert G; Clevers, Hans; Voest, Emile E

    2015-10-27

    Tumor organoids are 3D cultures of cancer cells. They can be derived from the tumor of each individual patient, thereby providing an attractive ex vivo assay to tailor treatment. Using patient-derived tumor organoids for this purpose requires that organoids derived from biopsies maintain the genetic diversity of the in vivo tumor. In this study tumor biopsies were obtained from 14 patients with metastatic colorectal cancer (i) to test the feasibility of organoid culture from metastatic biopsy specimens and (ii) to compare the genetic diversity of patient-derived tumor organoids and the original tumor biopsy. Genetic analysis was performed using SOLiD sequencing for 1,977 cancer-relevant genes. Copy number profiles were generated from sequencing data using CopywriteR. Here we demonstrate that organoid cultures can be established from tumor biopsies of patients with metastatic colorectal cancer with a success rate of 71%. Genetic analysis showed that organoids reflect the metastasis from which they were derived. Ninety percent of somatic mutations were shared between organoids and biopsies from the same patient, and the DNA copy number profiles of organoids and the corresponding original tumor show a correlation of 0.89. Most importantly, none of the mutations that were found exclusively in either the tumor or organoid culture are in driver genes or genes amenable for drug targeting. These findings support further exploration of patient-derived organoids as an ex vivo platform to personalize anticancer treatment.

  7. Evaluation of the accuracy and precision three-dimensional sterotactic breast biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Mi Hwa [Dept. of Health Care, Hanseo University, Seosan (Korea, Republic of)

    2015-09-15

    This research was study the accuracy of three dimensional stereotactic breast biopsy, using a core Needle Biopsy and to assess the accuracy of Stereotactic biopsy and Sono guided biopsy. Using Stereotactic QC phantom to measure the accuracy of the 3D sterotactic machine. CT Scan and equipment obtained in the measured X, Y, Z and compares the accuracy of the length. Using Agar power phantom compare the accuracy of the 3D sterotactic machine and 2D ultrasound machine. Z axis measured by the equipment to compare the accuracy and reliability. Check the accuracy by using visual inspection and Specimen Medical application phantom. The accuracy of the 3D sterotactic machine measured by Stereotactic QC phantom was 100%. Accuracy as compared to CT, all of X, Y, Z axis is p > 0.05. The accuracy of the two devices was 100% as measured by Agar powder phantom. There was no difference between the two devices as CT and p > 0.05. 3D sterotactic machine of the ICC was 0.954, 2D ultrasound machine was 0.785. 2D ultrasound machine was different according to the inspector. Medical application phantom experiments in 3D sterotactic machine could not find the Sliced boneless ham. 2D ultrasound machine has not been able to find a small chalk powder group. The reproducibility of the three dimensional stereotactic breast biopsy was better than effect of Sono guided biopsy.

  8. Percutaneous transbiliary biopsy.

    Science.gov (United States)

    Andrade, Gustavo Vieira; Santos, Miguel Arcanjo; Meira, Marconi Roberto; Meira, Mateus Duarte

    2017-01-01

    Percutaneous drainage of the bile ducts is an established procedure for malignant obstructions, in which a histological diagnosis is often not obtained. We describe the biopsy technique of obstructive lesions through biliary drainage access, using a 7F endoscopic biopsy forceps, widely available; some are even reusable. This technique applies to lesions of the hepatic ducts, of the common hepatic duct and of all extension of the common bile duct. RESUMO A drenagem percutânea das vias biliares é um procedimento estabelecido para obstruções malignas, nos quais, muitas vezes, não se consegue um diagnóstico histológico. Descrevemos a técnica de biópsia da lesão obstrutiva através do acesso de drenagem biliar, utilizando um fórcipe de biópsia endoscópica 7F, amplamente disponível e alguns reutilizáveis. Esta técnica aplica-se a lesões dos ductos hepáticos, do hepático comum e de toda extensão do colédoco.

  9. Ultrasound guided needle biopsy of skeletal muscle in neuromuscular disease

    DEFF Research Database (Denmark)

    Lindequist, S; Schrøder, H D; Larsen, C

    1990-01-01

    Guided by ultrasonography percutaneous needle biopsy of skeletal muscle was performed in 24 patients, using the one hand held Biopty system and a 2 mm Tru-Cut needle. The specimens were graded with regard to diagnostic quality and utility and almost all specimens (96%) were of highest quality....... The use of ultrasonography was helpful in selecting a suitable area for the biopsy and vascular structures could be avoided. The procedure was well tolerated and easy to perform, and no complications were recorded....

  10. Analysis of prostate cancer localization toward improved diagnostic accuracy of transperineal prostate biopsy

    Directory of Open Access Journals (Sweden)

    Yoshiro Sakamoto

    2014-09-01

    Conclusions: The concordance of prostate cancer between prostatectomy specimens and biopsies is comparatively favorable. According to our study, the diagnostic accuracy of transperineal prostate biopsy can be improved in our institute by including the anterior portion of the Apex-Mid and Mid regions in the 12-core biopsy or 16-core biopsy, such that a 4-core biopsy of the anterior portion is included.

  11. Pathological discrepancy between colposcopic directed cervical biopsy and Loop Electrosurgical-Excision Procedures (LEEPs in patients with biopsies proven high grade cervical intraepithelial neoplasia

    Directory of Open Access Journals (Sweden)

    Sitchuphong Noothong

    2017-10-01

    Conclusion: The prevalence of patients with CIN1 or less from LEEP specimens who previously had colposcopic biopsies proven CIN2 or 3 was 16.3%. CIN2 from biopsy was the statistically significant risk factor of CIN1 or less in LEEP specimens.

  12. Ultrasound-Guided Breast Biopsy

    Science.gov (United States)

    ... Physician Resources Professions Site Index A-Z Ultrasound-Guided Breast Biopsy An ultrasound-guided breast biopsy uses ... of Ultrasound-Guided Breast Biopsy? What is Ultrasound-Guided Breast Biopsy? Lumps or abnormalities in the breast ...

  13. Rotating specimen rack repair

    International Nuclear Information System (INIS)

    Miller, G.E.; Rogers, P.J.; Nabor, W.G.; Bair, H.

    1984-01-01

    In 1980, an operator at the UCI TRIGA Reactor noticed difficulties with the rotation of the specimen rack. Investigations showed that the drive bearing in the rack had failed and allowed the bearings to enter the rack. After some time of operation in static mode it was decided that installation of a bearing substitute - a graphite sleeve - would be undertaken. Procedures were written and approved for removal of the rack, fabrication and installation of the sleeve, and re-installation of the rack. This paper describes these procedures in some detail. Detailed drawings of the necessary parts may be obtained from the authors

  14. US-Guided Vacuum-Assisted Biopsy of Microcalcifications in Breast Lesions and Long-Term Follow-Up Results

    Science.gov (United States)

    Kim, Hua Sun; Kim, Eun-Kyung; Kwak, Jin Young; Son, Eun Ju; Oh, Ki Keun

    2008-01-01

    Objective To evaluate the diagnostic accuracy of the use of an ultrasonography (US)-guided vacuum-assisted biopsy for microcalcifications of breast lesions and to evaluate the efficacy of the use of US-guided vacuum-assisted biopsy with long-term follow-up results. Materials and Methods US-guided vacuum-assisted biopsy cases of breast lesions that were performed between 2002 and 2006 for microcalcifications were retrospectively reviewed. A total of 62 breast lesions were identified where further pathological confirmation was obtained or where at least two years of mammography follow-up was obtained. These lesions were divided into the benign and malignant lesions (benign and malignant group) and were divided into underestimated group and not-underestimated lesions (underestimated and not-underestimated group) according to the diagnosis after a vacuum-assisted biopsy. The total number of specimens that contained microcalcifications was analyzed and the total number of microcalcification flecks as depicted on specimen mammography was analyzed to determine if there was any statistical difference between the groups. Results There were no false negative cases after more than two years of follow-up. Twenty-nine lesions were diagnosed as malignant (two invasive carcinomas and 27 carcinoma in situ lesions). Two of the 27 carcinoma in situ lesions were upgraded to invasive cancers after surgery. Among three patients diagnosed with atypical ductal hyperplasia, the diagnosis was upgraded to a ductal carcinoma in situ after surgery in one patient. There was no statistically significant difference in the number of specimens with microcalcifications and the total number of microcalcification flecks between the benign group and malignant group of patients and between the underestimated group and not-underestimated group of patients. Conclusion US-guided vacuum-assisted biopsy can be an effective alternative to stereotactic-guided vacuum-assisted biopsy in cases where

  15. Loss of high-molecular-weight cytokeratin antigenicity in prostate tissue obtained by transurethral resections.

    Science.gov (United States)

    Multhaupt, H A; Fessler, J N; Warhol, M J

    2000-12-01

    Staining of prostatic basal cells for the expression of high-molecular-weight cytokeratin has been suggested as a way of distinguishing benign from malignant prostate glands. We evaluated the utility of high-molecular-weight cytokeratin in the diagnosis of malignancy in prostate specimens obtained in various ways. Prostate tissues obtained from needle biopsies, transurethral resections, and total prostatectomies were immunostained with monoclonal antibody 34betaE12, an antibody directed against high-molecular-weight cytokeratins. Antiserum to high-molecular-weight cytokeratin only stained the basal cells in normal glands in 3 (12%) of 25 specimens obtained by transurethral resection. Other antigens, such as the alternate 10-nm filament protein vimentin, were unaffected and were detected in 100% of these specimens. However, keratin antigenicity in transurethral biopsies could be restored in these specimens by antigen retrieval in a low pH citrate buffer using a microwave heat technique. Keratin staining in needle biopsies and total prostatectomies was unaffected. In summary, our results indicate the technique of transurethral resection results in a specific loss of keratin antigenicity. This limits the utility of anticytokeratin 34betaE12 in interpreting transurethral resections without the application of antigen retrieval.

  16. Incision for pleural tissue biopsy (image)

    Science.gov (United States)

    ... open pleural biopsy, a small piece of the pleural tissue is removed through a surgical incision in the chest. After the sample is obtained, a chest tube is placed and the incision is closed with ...

  17. HISTOMORPHOLOGICAL PROFILE OF PROSTATE BIOPSIES AND CORRELATION WITH SERUM TPSA LEVEL

    Directory of Open Access Journals (Sweden)

    Laishram Deepak Kumar

    2017-11-01

    Full Text Available BACKGROUND In our study, 50 cases of transurethral prostate biopsies were evaluated histopathologically in the Department of Pathology in collaboration with Department of Urology, Regional Institute of Medical Sciences, Imphal, from October 2013 to September 2015. Total PSA (tPSA was estimated from serum samples in all cases. MATERIALS AND METHODS A total of 50 patients with elevated serum tPSA levels were inducted in this study and prostate needle biopsies taken. Matched prostatectomy specimens were also obtained for 7 cases. Specimens were kept in 10% formalin saline, grossing done and tissues processed. H and E stained sections were examined and the different histomorphological features noted. Gleason scoring system was used in cancers to stratify it. RESULTS Out of the 50 cases, 30 malignant (all adenocarcinomas, 4 premalignant and 16 benign cases were found. Gleason scoring on needle biopsies were compared against the prostatectomy specimens. In 5 carcinoma cases with Gleason score 3+3=6 on needle biopsy, 4 cases had similar findings in the corresponding prostatectomy specimens, however, it was upgraded in 1 case. Intermediate differentiation prostatic carcinomas with Gleason score 3+4=7 in needle biopsies were comparable with prostatectomy specimens in 2 cases. The differentiation of prostatic carcinoma vis-a-vis Gleason scoring correlated well with the PSA values. In carcinomas, tPSA value and the Gleason score had a very good correlation (rs = 0.908. Mean PSA value was found to increase from benign to premalignant and malignant cases, this was found to be statistically significant (p<0.05. CONCLUSION Use of newer technologies like MRI and serum PSA as a screening tool for prostate pathology have made it possible to identify prostate cancer at an earlier stage in younger age group and has an increased case detection rate. However, there is no marker to predict disease course and at times lead to overtreatment. Image-guided prostate biopsy

  18. Accuracy of percutaneous lung biopsy for invasive pulmonary aspergillosis

    International Nuclear Information System (INIS)

    Hoffer, F.A.; Gow, K.; Davidoff, A.; Flynn, P.M.

    2001-01-01

    Background. Invasive pulmonary aspergillosis is fulminant and often fatal in immunosuppressed patients. Percutaneous biopsy may select patients who could benefit from surgical resection. Objective. We sought to determine the accuracy of percutaneous biopsy for pediatric invasive pulmonary aspergillosis. Materials and methods. We retrospectively reviewed 28 imaging-guided percutaneous biopsies of the lungs of 24 children with suspected pulmonary aspergillosis. Twenty-two were being treated for malignancy and two for congenital immunodeficiency; 15 had received bone-marrow transplants. The accuracy of the percutaneous lung biopsy was determined by subsequent surgical resection, autopsy, or clinical course. Results. Histopathological studies showed ten biopsy specimens with septate hyphae, indicating a mold, and seven with Aspergillus flavus colonies in culture. The remaining 18 biopsies revealed no fungi. No patient had progressive aspergillosis after negative biopsy. Invasive pulmonary mold was detected by percutaneous biopsy with 100 % (10/10) sensitivity and 100 % (18/18) specificity. Percutaneous biopsy results influenced the surgical decision in 86 % (24 of 28) of the cases. Bleeding complicated the biopsy in 46 % (13/28) and hastened one death. Conclusion. Percutaneous biopsy of the lung is an accurate technique for the diagnosis of invasive pulmonary aspergillosis and correctly determines which immunosuppressed pediatric patients would benefit from therapeutic pulmonary resection. (orig.)

  19. Delayed culture of Leishmania in skin biopsies.

    Science.gov (United States)

    Dedet, J P; Pratlong, F; Pradinaud, R; Moreau, B

    1999-01-01

    Between January 1997 and October 1998, 16 skin biopsies collected from 13 patients with cutaneous leishmaniasis in French Guiana were inoculated in culture medium after travel for 3-17 days from the place of biopsy to the culture laboratory in France. Each biopsy fragment was introduced near the flame of a Bunsen burner into the transport medium (RPMI medium supplemented with 10% fetal calf serum) which was maintained at ambient temperature during postal delivery to France. In France the biopsies were ground in sterile saline before being inoculated into NNN culture tubes. The cultures were incubated at 25 degrees C and subcultured every week until the 5th week. The cultures were positive in 9 cases, remained negative in 4, and were contaminated in 3 cases. Positive results were obtained at all seasons and for 3 different Leishmania species. The study indicates that delayed culture can yield useful results from biopsies taken in field conditions.

  20. Fine-needle aspiration biopsy of synovial sarcoma. A cytomorphologic analysis of primary, recurrent, and metastatic tumors.

    Science.gov (United States)

    Kilpatrick, S E; Teot, L A; Stanley, M W; Ward, W G; Savage, P D; Geisinger, K R

    1996-12-01

    Thirteen fine-needle aspiration specimens from 10 patients with histologically proven synovial sarcoma are described. The aspiration biopsy specimens were obtained from the primary tumor in five cases, locally recurrent tumors in four cases, pulmonary metastases in three cases, and mediastinal metastasis in one case. Patient's ages ranged from 22 years to 65 years; there were four women and six men. All cases had a confirmation biopsy and/or resection specimen that were reviewed. Histologic subtypes included monophasic fibrous (5 cases), monophasic epithelial (1 case), biphasic (3 cases), and poorly differentiated (1 case). The majority of the aspiration biopsy specimens were similar with moderate to marked smear cellularity dominated by cohesive clusters of spindle-shaped cells with ovoid, hyperchromatic nuclei and scanty tapering cytoplasm. Nucleoli were not prominent. Epithelial tumor cells with ovoid to round, mostly regular, centrally to eccentrically located nuclei, surrounded by scant to abundant cytoplasm predominated in one case (monophasic epithelial) and were admixed with spindle cells in a second (classical biphasic). Multi-nucleated tumor giant cells were not observed in any of the tumors. In biphasic synovial sarcoma, the neoplastic spindle cells are generally more numerous and frequent than the epithelial cells, making distinction from monophasic synovial sarcoma or other spindle cell soft tissue tumors difficult. Although synovial sarcoma may be diagnosed by fine-needle aspiration cytology, clinical correlation, especially in monophasic types, is necessary to minimize errors in sarcoma classification.

  1. Evaluation of novel slim biopsy forceps for diagnosis of biliary strictures: Single-institutional study of consecutive 360 cases (with video).

    Science.gov (United States)

    Yamamoto, Kenjiro; Tsuchiya, Takayoshi; Itoi, Takao; Tsuji, Shujiro; Tanaka, Reina; Tonozuka, Ryosuke; Honjo, Mitsuyoshi; Mukai, Shuntaro; Kamada, Kentaro; Fujita, Mitsuru; Asai, Yasutsugu; Matsunami, Yukitoshi; Nagakawa, Yuichi; Yamaguchi, Hiroshi; Sofuni, Atsushi

    2017-09-21

    To evaluate the feasibility and reliability of endoscopic transpapillary bile duct biopsy for the diagnosis of biliary strictures. A total of 360 patients (241 men) who underwent endoscopic retrograde cholangiopancreatography for biliary strictures with biopsy from April 2012 to March 2016 at Tokyo Medical University Hospital were retrospectively reviewed. This study was approved by our Institutional Review Board (No. 3516). Informed consent was obtained from all individual participants included in this study. The biopsy specimens were obtained using a novel slim biopsy forceps (Radial Jaw 4P, Boston Scientific, Boston, MA, United States). The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were 69.6%, 100%, 100%, 59.1%, and 78.8%, respectively. The sensitivity was 75.6% in bile duct cancer, 64% in pancreatic cancer, 61.1% in gallbladder cancer, and 57.1% in metastasis. In bile duct cancer, a lower sensitivity was observed for perihilar bile duct stricture (68.7%) than for distal bile duct stricture (83.1%). In terms of the stricture lengths of pancreatic cancer, gallbladder cancer, and metastasis, a longer stenosis resulted in a better sensitivity. In particular, there was a significant difference between pancreatic cancer and gallbladder cancer ( P < 0.05). One major complication was perforation of the extrahepatic bile duct with bile leakage. Endoscopic transpapillary biopsy alone using novel slim biopsy forceps is feasible and reliable, but restrictive. Biopsy should be performed in consideration of the stricture level, stricture length, and cancer type.

  2. Urine culture - catheterized specimen

    Science.gov (United States)

    Culture - urine - catheterized specimen; Urine culture - catheterization; Catheterized urine specimen culture ... Normal values depend on the test being performed. Normal results are reported as "no growth" and are a sign ...

  3. Evaluation of chronic infectious interstitial pulmonary disease in children by low-dose CT-guided transthoracic lung biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Heyer, Christoph M.; Lemburg, Stefan P.; Kagel, Thomas; Nicolas, Volkmar [Ruhr-University of Bochum, Institute of Diagnostic Radiology, Interventional Radiology and Nuclear Medicine, BG Clinics Bergmannsheil, Bochum (Germany); Mueller, Klaus-Michael [Ruhr-University of Bochum, Institute of Pathology, BG Clinics Bergmannsheil, Bochum (Germany); Nuesslein, Thomas G.; Rieger, Christian H.L. [Ruhr-University of Bochum, Pediatric Hospital, Bochum (Germany)

    2005-07-01

    Children with chronic infectious interstitial lung disease often have to undergo open lung biopsy to establish a final diagnosis. Open lung biopsy is an invasive procedure with major potential complications. Transthoracic lung biopsy (TLB) guided by computed tomography (CT) is a less-invasive well-established procedure in adults. Detailing the role of low-dose CT-guided TLB in the enhanced diagnosis of chronic lung diseases related to infection in children. A group of 11 children (age 8 months to 16 years) underwent CT-guided TLB with a 20-gauge biopsy device. All investigations were done under general anaesthesia on a multidetector CT scanner (SOMATOM Volume Zoom, Siemens, Erlangen, Germany) using a low-dose protocol (single slices, 120 kV, 20 mAs). Specimens were processed by histopathological, bacteriological, and virological techniques. All biopsies were performed without major complications; one child developed a small pneumothorax that resolved spontaneously. A diagnosis could be obtained in 10 of the 11 patients. Biopsy specimens revealed chronic interstitial alveolitis in ten patients. In five patients Chlamydia pneumoniae PCR was positive, in three Mycoplasma pneumoniae PCR was positive, and in two Cytomegalovirus PCR was positive. The average effective dose was 0.83 mSv. Low-dose CT-guided TLB can be a helpful tool in investigating chronic infectious inflammatory processes in children with minimal radiation exposure. It should be considered prior to any open surgical procedure performed for biopsy alone. In our patient group no significant complication occurred. A disadvantage of the method is that it does not allow smaller airways and vessels to be assessed. (orig.)

  4. Mediastinoscopy with biopsy

    Science.gov (United States)

    ... This procedure is also done for certain infections (tuberculosis, sarcoidosis) and autoimmune disorders . ... Biopsies of lymph node tissues are normal and do not show signs of cancer or infection.

  5. Salivary gland biopsy

    Science.gov (United States)

    ... biopsy References Miloro M, Kolokythas A. Diagnosis and management of salivary gland disorders. In: Hupp JR, Ellis E, Tucker MR, eds. Contemporary Oral and Maxillofacial Surgery . 6th ed. St Louis, ...

  6. Colposcopy - directed biopsy

    Science.gov (United States)

    ... squamous cells - colposcopy; Pap smear - colposcopy; HPV - colposcopy; Human papilloma virus - colposcopy; Cervix - colposcopy; Colposcopy ... also called cervical dysplasia) Cervical warts (infection with human papilloma virus , or HPV) If the biopsy does not determine ...

  7. Biopsy (For Parents)

    Science.gov (United States)

    ... is taking or whether your child has any allergies. Be sure to report any bleeding tendencies in your child, and whether your daughter might be pregnant. Some biopsies require only local anesthesia. Others require sedation or general anesthesia. If that's ...

  8. Corpus vitreum, retina og chorioidea biopsi

    DEFF Research Database (Denmark)

    Scherfig, Erik Christian Høegh

    2002-01-01

    oftalmology, biopsy, choroid, corpus vitreum, retina, malignant melanoma, biopsy technic, retinoblastoma......oftalmology, biopsy, choroid, corpus vitreum, retina, malignant melanoma, biopsy technic, retinoblastoma...

  9. Transvenous liver biopsy via the femoral vein

    International Nuclear Information System (INIS)

    Khosa, F.; McNulty, J.G.; Hickey, N.; O'Brien, P.; Tobin, A.; Noonan, N.; Ryan, B.; Keeling, P.W.N.; Kelleher, D.P.; McDonald, G.S.A.

    2003-01-01

    AIM: To study the safety, effectiveness and diagnostic value of transvenous forceps biopsy of the liver in 54 patients with coagulopathy, gross ascites or morbid obesity and suspected liver disease in whom percutaneous liver biopsy was contraindicated. MATERIAL AND METHODS: Forceps biopsy of the liver via the femoral vein was attempted in 54 adult patients with advanced liver disease of unknown aetiology who had coagulation disorders (41 cases), gross ascites (11 cases) or morbid obesity (two cases). In each patient two to six biopsies (average four) were taken using a radial jaw forceps inserted via the right or left femoral vein. RESULTS: The procedure was successful in 53 cases. Hepatic vein catheterization failed in one patient. Adequate liver tissue for diagnosis was obtained in 84% of cases. One patient developed delayed haemorrhage at 12 h from a capsular leak that was undetected during the biopsy procedure. This patient required blood transfusions and laparotomy to control bleeding. There were no deaths in the 53 patients studied. Transient minor chest and shoulder pain was encountered during sheath insertion into a hepatic vein in 23 patients. Three patients developed a femoral vein haematoma, which resolved with conservative treatment. CONCLUSION: Transvenous liver biopsy via the femoral vein is another safe, effective, simple alternative technique of biopsy when the percutaneous route is contraindicated

  10. Effect of needle gauge and lobe laterality on parenchymal liver biopsy outcome: a retrospective analysis.

    Science.gov (United States)

    Vijayaraghavan, Gopal R; Vedantham, Srinivasan; Rangan, Vikram; Karam, Adib; Zheng, Larry; Roychowdhury, Abhijit; Hussain, Sarwat

    2015-06-01

    To analyze the effect of lobe selection, needle gauge, and number of passes on procedure outcomes in terms of specimen length and post-procedure complications. In this HIPAA-compliant, IRB-approved retrospective study, the data from 771 ultrasound-guided adult parenchymal liver biopsies were analyzed. Post-procedure complications were assigned a 3-point rating scale. Associations between specimen length and post-procedure complications with lobe laterality, needle gauge, and number of passes were analyzed. Multivariate logistic regression models were used to analyze the likelihood for achieving a specimen length of at least 2 cm. Post-procedure complications were not associated with lobe laterality, needle gauge, and number of passes (p > 0.3). Specimen length was associated with the number of passes dichotomized at the study mean (p = 0.007), but not with lobe laterality or needle gauge (p > 0.2). After adjusting for lobe laterality and needle gauge, procedures with 1 or 2 passes were associated with a higher likelihood of obtaining a 2 cm or longer specimen (OR 2.469; CI 1.08-5.63, p = 0.0315) than procedures with 3 or more passes, possibly due to poorer sample quality. After adjusting for lobe laterality, an 18-gauge needle was associated with higher odds of a biopsy procedure with 1 or 2 passes (OR 3.665; CI 1.93-6.95, p gauge needle. Lobe laterality was not associated with specimen length or post-procedure complications. An 18-gauge needle compared to a 20-gauge needle could reduce the need for a procedure with more than 2 passes. There was no difference in post-procedure complications between the two needle sizes.

  11. Development of Reconstitution Technology for Surveillance Specimens

    International Nuclear Information System (INIS)

    Yasushi Atago; Shunichi Hatano; Eiichiro Otsuka

    2002-01-01

    The Japan Power Engineering and Inspection Corporation (JAPEIC) has been carrying out the project titled 'Nuclear Power Plant Integrated Management Technology (PLIM)' consigned by Japanese Ministry of Economy, Trade and Industry (METI) since 1996FY as a 10-years project. As one of the project themes, development of reconstitution technology for reactor pressure vessel (RPV/RV) surveillance specimens, which are installed in RPVs to monitor the neutron irradiation embrittlement on RPV/RV materials, is now on being carried out to deal with the long-term operation of nuclear power plants. The target of this theme is to establish the technical standard for applicability of reconstituted surveillance specimens including the reconstitution of the Charpy specimens and Compact Tension (CT) specimens. With the Charpy specimen reconstitution, application of 10 mm length inserts is used, which enables the conversion of tests from the LT-direction to the TL-direction. This paper presents the basic data from Charpy and CT specimens of RPV materials using the surveillance specimens obtained for un-irradiated materials including the following. 1) Reconstitution Technology of Charpy Specimens. a) The interaction between plastic zone and Heat Affected Zone (HAZ). b) The effects of the possible deviations from the standard specimens for the reconstituted specimens. 2) Reconstitution Technology of CT specimens. a) The correlation between fracture toughness and plastic zone width. Because the project is now in progress, this paper describes the outline of the results obtained as of the end of 2000 FY. (authors)

  12. Aortography following subdiaphragmal aortic biopsy

    International Nuclear Information System (INIS)

    Schimmler, J.

    1982-01-01

    A juxtaposition of the subdiaphragmal and infrarenal translumbar aortic biopsy sites showed decisive advantages in favour of the higher site: a more stable position because of better anatomic fixation and rarer incidence of vascular alterations, a wider vascular lumen. Disadvantages lie in the fact that the large visceral arteries (especially Tr. coeliacus) branch off nearly and in the close anatomic relationship to large abdominal organs and the thoracal region. Evaluation of the radiographical image of the vascular tree after subdiaphragmal aortic biopsy showed an average 82% of the vessels to the area of the Knees to be assessable (renal arteries approximately 93%, popliteal arteries approximately 70%). Beyong, the method proved unsatisfactory: 52% of the vessels could not, or not safety, be evaluated. A relatively broad spectrum of indications by comparison with transfemoral catheter aortography had no influence on the rate of complications with reference to either method. A comparison of the topographic conditions shows the need for even more scrupulons observation of the technique in subdiaphragmal biopsy than in the infrarenal one. To sum up the results obtained, subdiaphregmal translumbar aortography is to be preferred to the infrarenal one where transfemoral catheter aortography is contra-indicated, within the limits mentioned. (orig.) [de

  13. Endoscopic biopsy of foramen of Monro and third ventricle lesions guided by frameless neuronavigation: usefulness and limitations.

    Science.gov (United States)

    Prat, Ricardo; Galeano, Inmaculada

    2009-09-01

    To describe our institution experience regarding the usefulness and limitations of frameless neuronavigation in the endoscopic biopsy of foramen of Monro and third ventricle lesions. We report our experience with 22 patients harbouring intraventricular lesions located in the region of the foramen of Monro or the third ventricle who underwent endoscopic biopsy guided by the neuronavigation system. Nine lesions were located on the posterior aspect of the third ventricle or at the pineal region, and thirteen lesions were located at the foramen of Monro or anterior third ventricle region. The endoscopes were introduced via an operating sheath, which had previously been inserted with a trocar under neuronavigational control. After approaching the foramen of Monro from the planned angle, surgery was continued under direct visualisation until the lesion was reached, if it was located on the third ventricle. In cases where the lesion was located at the foramen of Monro, an excellent view of the lesion was obtained and neuronavigation was used to determine the location of critical areas. Histological examination of biopsy specimens obtained endoscopically was diagnostic in all cases. Open surgery following endoscopic biopsy was only needed in 1 patient out of 22. In our experience, image-guided neuroendoscopy can improve the accuracy of the endoscopic approach, minimising brain trauma. It can be particularly helpful when performing a brain biopsy in the absence of clear intraventricular landmarks or in the event of adverse visual conditions such as intraventricular bleeding.

  14. Ultrasound-guided percutaneous biopsy of digestive tract lesions; Biopsia percutanea de lesiones del tubo digestivo guiada por ecografia

    Energy Technology Data Exchange (ETDEWEB)

    Gil, S.; Martin, I.; Ballesteros, J. M.; Gomez, C. [Hospital General Universitario de Alicante (Spain); Marco, S. F.; Fernandez, P. [Hospital Gneral de Castellon (Spain)

    1999-07-01

    To present our experience in ultrasound-guided percutaneous biopsy of lesions located in the digestive tract. We performed ultrasound-guided percutaneous biopsy in 14 patients (10 men and 4 women) ranging in age from 7 to 71 years (mean; 519 years). The lesions were located throughout the digestive tract, from the pyriform sinus to the sigmoid colon. The biopsy was carried out with a 5 MHz convex probe equipped with a device to direct the needle. An 18G automatic needle or a 20G Chiba needle was used to obtain specimens for histological study in every case, and additional samples were collected with a 22G needle for cytological examination in 13 of the patients. The ultrasound images corresponded to pseudokidney in 9 cases and extrinsic masses in 5. The diagnosis was obtained from the histological examination in every case (100%) and from cytology in 6 (44.4%), the latter results were less specific. The only complication corresponded to a case of bilioperitoneum. Ultrasound-guided percutaneous biopsy is a suitable technique for the histological diagnosis of those lesions of the digestive tract that are visible in ultrasound images, but that for some reason can not be examined by endoscopic biopsy. (Author) 20 refs.

  15. Diagnostic Ability of Percutaneous Needle Biopsy Immediately After Radiofrequency Ablation for Malignant Lung Tumors: An Initial Experience

    International Nuclear Information System (INIS)

    Hasegawa, Takaaki; Kondo, Chiaki; Sato, Yozo; Inaba, Yoshitaka; Yamaura, Hidekazu; Kato, Mina; Murata, Shinichi; Onoda, Yui; Kuroda, Hiroaki; Sakao, Yukinori; Yatabe, Yasushi

    2016-01-01

    PurposeTo evaluate the safety and diagnostic ability of percutaneous needle biopsy performed immediately after lung radiofrequency ablation (RFA).Materials and MethodsFrom May 2013 to April 2014, percutaneous needle biopsy was performed immediately after RFA for 3 patients (2 men and 1 woman, aged 57–76 years) who had lung tumors measuring 1.3–2.6 cm in diameter. All patients had prior history of malignancy, and all tumors were radiologically diagnosed as malignant. Obtained specimens were pathologically classified using standard hematoxylin and eosin staining.ResultsWe completed three planned sessions of RFA followed by percutaneous needle biopsy, all of which obtained tumor tissue that could be pathologically diagnosed. Two tumors were metastatic from renal clear cell carcinoma and rectal adenocarcinoma, respectively; one tumor was primary lung adenocarcinoma. There was no death or major complication related to the procedures. Although pneumothorax occurred in two patients, these resolved without the need for aspiration or chest tube placement. Tumor seeding was not observed, but 21 months after the procedure, one case developed local tumor progression that was treated by additional RFA.ConclusionPathologic diagnosis was possible by needle biopsy immediately after RFA for lung tumors. This technique may reduce the risks and efforts of performing biopsy and RFA on separate occasions.

  16. Diagnostic Ability of Percutaneous Needle Biopsy Immediately After Radiofrequency Ablation for Malignant Lung Tumors: An Initial Experience

    Energy Technology Data Exchange (ETDEWEB)

    Hasegawa, Takaaki, E-mail: t-hasegawa@aichi-cc.jp [Aichi Cancer Center Hospital, Department of Diagnostic and Interventional Radiology (Japan); Kondo, Chiaki [Aichi Cancer Center Hospital, Department of Pathology and Molecular Diagnosis (Japan); Sato, Yozo; Inaba, Yoshitaka; Yamaura, Hidekazu; Kato, Mina; Murata, Shinichi; Onoda, Yui [Aichi Cancer Center Hospital, Department of Diagnostic and Interventional Radiology (Japan); Kuroda, Hiroaki; Sakao, Yukinori [Aichi Cancer Center Hospital, Department of Thoracic Surgery (Japan); Yatabe, Yasushi [Aichi Cancer Center Hospital, Department of Pathology and Molecular Diagnosis (Japan)

    2016-08-15

    PurposeTo evaluate the safety and diagnostic ability of percutaneous needle biopsy performed immediately after lung radiofrequency ablation (RFA).Materials and MethodsFrom May 2013 to April 2014, percutaneous needle biopsy was performed immediately after RFA for 3 patients (2 men and 1 woman, aged 57–76 years) who had lung tumors measuring 1.3–2.6 cm in diameter. All patients had prior history of malignancy, and all tumors were radiologically diagnosed as malignant. Obtained specimens were pathologically classified using standard hematoxylin and eosin staining.ResultsWe completed three planned sessions of RFA followed by percutaneous needle biopsy, all of which obtained tumor tissue that could be pathologically diagnosed. Two tumors were metastatic from renal clear cell carcinoma and rectal adenocarcinoma, respectively; one tumor was primary lung adenocarcinoma. There was no death or major complication related to the procedures. Although pneumothorax occurred in two patients, these resolved without the need for aspiration or chest tube placement. Tumor seeding was not observed, but 21 months after the procedure, one case developed local tumor progression that was treated by additional RFA.ConclusionPathologic diagnosis was possible by needle biopsy immediately after RFA for lung tumors. This technique may reduce the risks and efforts of performing biopsy and RFA on separate occasions.

  17. Use of diagnostic dynamic contrast-enhanced (DCE)-MRI for targeting of soft tissue tumour biopsies at 3T: preliminary results

    International Nuclear Information System (INIS)

    Noebauer-Huhmann, Iris-Melanie; Amann, Gabriele; Krssak, Martin; Panotopoulos, Joannis; Funovics, Philipp; Windhager, Reinhard; Szomolanyi, Pavol; Weber, Michael; Czerny, Christian; Nemec, Stefan; Breitenseher, Martin; Grabner, Guenther; Bogner, Wolfgang; Dominkus, Martin; Trattnig, Siegfried

    2015-01-01

    To test the feasibility and accuracy of MR-guided soft tissue tumour biopsy at 3T, using the dynamic contrast-enhanced (DCE) information from staging MRI for intralesional targeting. After obtaining written informed consent for this institutional review board-approved study, 53 patients with suspected soft tissue tumours prospectively underwent preoperative staging MRI at 3T, including DCE, and subsequent MR-guided core needle biopsy. In 44/53 cases, DCE was heterogeneous and was used for intralesional biopsy targeting. Surgical, whole-specimen histology was used as the gold standard in 43/44 patients and revealed 42 soft tissue tumours (24 men; 18 women; mean age, 52 years; range, 19 - 84). Final surgical histology revealed eight benign lesions, six tumours of intermediate dignity, and 28 malignancies. All malignancies had shown heterogeneous DCE. The diagnostic yield of the biopsies was 100 % (42/42). Histological accuracy rates of biopsy were 100 % in predicting the dignity (42/42; 95 % CI [0.916 - 1.000]), 95.2 % for the tissue-specific entity (40/42; 95 % CI [0.847 - 0.987]), and 90.5 % for the tumour grade (38/42; 95 % CI [0.779 - 0.962]). Our preliminary study indicates that biopsy of soft tissue tumours can be performed accurately and safely with DCE targeted MR-guidance at 3T, using a combined staging/biopsy MRI protocol. (orig.)

  18. Use of diagnostic dynamic contrast-enhanced (DCE)-MRI for targeting of soft tissue tumour biopsies at 3T: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Noebauer-Huhmann, Iris-Melanie [Medical University of Vienna, Department of Biomedical Imaging and Image-guided Therapy, Division of Neuroradiology and Musculoskeletal Radiology, Vienna (Austria); Medical University of Vienna, High Field MR Center, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria); Medical University of Vienna/Vienna General Hospital, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria); Amann, Gabriele [Medical University of Vienna, Clinical Institute for Pathology, Vienna (Austria); Krssak, Martin [Medical University of Vienna, High Field MR Center, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria); Medical University of Vienna, Department of Internal Medicine III, Endocrinology and Metabolism, Vienna (Austria); Panotopoulos, Joannis; Funovics, Philipp; Windhager, Reinhard [Medical University of Vienna, Department of Orthopaedics, Vienna (Austria); Szomolanyi, Pavol [Medical University of Vienna, High Field MR Center, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria); Slovak Academy of Sciences, Department of Imaging Methods, Institute of Measurement Science, Bratislava (Slovakia); Weber, Michael; Czerny, Christian; Nemec, Stefan [Medical University of Vienna, Department of Biomedical Imaging and Image-guided Therapy, Division of Neuroradiology and Musculoskeletal Radiology, Vienna (Austria); Breitenseher, Martin [Landesklinikum Waldviertel Horn, Horn (Austria); Grabner, Guenther; Bogner, Wolfgang [Medical University of Vienna, High Field MR Center, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria); Dominkus, Martin [Orthopaedics Hospital Speising, Vienna (Austria); Trattnig, Siegfried [Medical University of Vienna, High Field MR Center, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria); Ludwig Boltzmann Institute for Experimental and Clinical Traumatology, Austrian Cluster for Tissue Regeneration, Vienna (Austria)

    2015-07-15

    To test the feasibility and accuracy of MR-guided soft tissue tumour biopsy at 3T, using the dynamic contrast-enhanced (DCE) information from staging MRI for intralesional targeting. After obtaining written informed consent for this institutional review board-approved study, 53 patients with suspected soft tissue tumours prospectively underwent preoperative staging MRI at 3T, including DCE, and subsequent MR-guided core needle biopsy. In 44/53 cases, DCE was heterogeneous and was used for intralesional biopsy targeting. Surgical, whole-specimen histology was used as the gold standard in 43/44 patients and revealed 42 soft tissue tumours (24 men; 18 women; mean age, 52 years; range, 19 - 84). Final surgical histology revealed eight benign lesions, six tumours of intermediate dignity, and 28 malignancies. All malignancies had shown heterogeneous DCE. The diagnostic yield of the biopsies was 100 % (42/42). Histological accuracy rates of biopsy were 100 % in predicting the dignity (42/42; 95 % CI [0.916 - 1.000]), 95.2 % for the tissue-specific entity (40/42; 95 % CI [0.847 - 0.987]), and 90.5 % for the tumour grade (38/42; 95 % CI [0.779 - 0.962]). Our preliminary study indicates that biopsy of soft tissue tumours can be performed accurately and safely with DCE targeted MR-guidance at 3T, using a combined staging/biopsy MRI protocol. (orig.)

  19. Computed tomography-guided percutaneous biopsy of bone lesions: rate of diagnostic success and complications

    Energy Technology Data Exchange (ETDEWEB)

    Maciel, Macello Jose Sampaio; Tyng, Chiang Jeng; Barbosa, Paula Nicole Vieira Pinto; Bitencourt, Almir Galvao Vieira; Matushita Junior, Joao Paulo Kawaoka; Zurstrassen, Charles Edouard; Chung, Wu Tu; Chojniak, Rubens, E-mail: macellomaciel@me.com [A.C.Camargo Cancer Center, Sao Paulo, SP (Brazil)

    2014-09-15

    Objective: To determine the rates of diagnostic success and complications of computed tomography (CT)-guided percutaneous biopsy of bone lesions suspected for malignancy. Materials and Methods: Retrospective study including 186 cases of CT-guided percutaneous biopsies of bone lesions in the period from January, 2010 to December, 2012. All the specimens were obtained with 8-10 gauge needles. The following data were collected: demographics, previous history of malignancy, data related to the lesion, to the procedure, and to histological results. Results: Most patients were women (57%), and the mean age was 53.0 ± 16.4 years. In 139 cases (74.6%), there was diagnostic suspicion of metastasis and the most common primary tumors were breast (32.1%) and prostate (11.8%). The bones most commonly involved were spine (36.0%), hip (32.8%) and long bones (18.3%). Complications occurred in only three cases (1.6%) including bone fracture, paraesthesia with functional impairment, and needle breakage requiring surgical removal. The specimens collected from 183 lesions (98.4%) were considered appropriate for diagnosis. Malignant results were more frequently found in patients who had a suspected secondary lesion and history of known malignancy (p < 0.001), and in patients who underwent PET/CT-guided procedures (p = 0.011). Conclusion: CT-guided percutaneous biopsy is a safe and effective procedure for the diagnosis of suspicious bone lesions. (author)

  20. Computed tomography-guided percutaneous biopsy of bone lesions: rate of diagnostic success and complications.

    Science.gov (United States)

    Maciel, Macello Jose Sampaio; Tyng, Chiang Jeng; Barbosa, Paula Nicole Vieira Pinto; Bitencourt, Almir Galvão Vieira; Matushita Junior, João Paulo Kawaoka; Zurstrassen, Charles Edouard; Chung, Wu Tu; Chojniak, Rubens

    2014-01-01

    To determine the rates of diagnostic success and complications of computed tomography (CT)-guided percutaneous biopsy of bone lesions suspected for malignancy. Retrospective study including 186 cases of CT-guided percutaneous biopsies of bone lesions in the period from January, 2010 to December, 2012. All the specimens were obtained with 8-10 gauge needles. The following data were collected: demographics, previous history of malignancy, data related to the lesion, to the procedure, and to histological results. Most patients were women (57%), and the mean age was 53.0 ± 16.4 years. In 139 cases (74.6%), there was diagnostic suspicion of metastasis and the most common primary tumors were breast (32.1%) and prostate (11.8%). The bones most commonly involved were spine (36.0%), hip (32.8%) and long bones (18.3%). Complications occurred in only three cases (1.6%) including bone fracture, paresthesia with functional impairment, and needle breakage requiring surgical removal. The specimens collected from 183 lesions (98.4%) were considered appropriate for diagnosis. Malignant results were more frequently found in patients who had a suspected secondary lesion and history of known malignancy (p guided procedures (p = 0.011). CT-guided percutaneous biopsy is a safe and effective procedure for the diagnosis of suspicious bone lesions.

  1. Postreperfusion biopsies are useful in predicting complications after liver transplantation.

    Science.gov (United States)

    Busquets, J; Figueras, J; Serrano, T; Torras, J; Ramos, E; Rafecas, A; Fabregat, J; Lama, C; Xiol, X; Baliellas, C; Jaurrieta, E

    2001-05-01

    Biliary complications after orthotopic liver transplantation (OLT) may occur because of preservation injury (PI). In this study, we examine findings on routine reperfusion biopsy specimens in relation to the occurrence of biliary complications and graft outcome. From 1997 to 2000, a total of 193 OLTs were performed in our center. Postreperfusion biopsy specimens were analyzed and histological lesions were graded. For analysis, grafts were grouped into 2 categories: the presence or absence of PI (severe to moderate lesions versus mild or no lesions). Histological evidence of PI was present in 17% of the biopsy specimens. The incidence of grafts with PI and ischemia time longer than 12 hours was 38% compared with 14% in PI and short ischemia time (P =.02). Biliary complications were also more frequent in the PI group (28% v 14%; P =.03). Study of risk factors by means of logistic regression analysis confirmed that the PI group had a greater risk for biliary complications (relative risk, 2.8; 95% confidence interval, 1 to 7.4; P =.03). Moreover, moderate macrovesicular steatosis was found in 6% of the grafts, resulting in a 40% graft loss rate. We found that an increased presence of neutrophilic infiltrates in the postreperfusion biopsy specimen, indicating PI, was related to an increased incidence of biliary complications. Moreover, moderate macrovesicular steatosis was associated with increased graft loss. Therefore, postreperfusion biopsies are useful in anticipating post-OLT complications.

  2. TEM Specimen Preparation

    OpenAIRE

    sprotocols

    2014-01-01

    Author: House Ear Institute ### Preparative Techniques for the TEM For routine transmission electron microscopy (TEM), it is generally accepted that specimens should be thin, dry and contain molecules which diffract electrons. Biological specimens, which are large and consist of large amounts of water, also do not defract electrons and are therefore difficult to see in the TEM. Preparing biological specimens for the TEM, whilst retaining the structural morphology of the material, is a...

  3. Laparoscopic specimen retrieval bags.

    Science.gov (United States)

    Smorgick, Noam

    2014-10-01

    Specimen retrieval bags have long been used in laparoscopic gynecologic surgery for contained removal of adnexal cysts and masses. More recently, the concerns regarding spread of malignant cells during mechanical morcellation of myoma have led to an additional use of specimen retrieval bags for contained "in-bag" morcellation. This review will discuss the indications for use retrieval bags in gynecologic endoscopy, and describe the different specimen bags available to date.

  4. Percutaneous Liver Biopsies Guided with Ultrasonography: A Case Series

    International Nuclear Information System (INIS)

    Cakmakci, Emin; Caliskan, Kosti Can; Tabakci, Omer Naci; Tahtabasi, Mehmet; Karpat, Zeki

    2013-01-01

    Although liver biopsy is an easy procedure for hospitalized patients and outpatients, some complications may occur. To evaluate the efficiency, complications, safety and clinicopathological utility of ultrasonographic-guided percutaneous liver biopsy in diffuse liver disease. In our retrospective study, we evaluated ultrasound-assisted needle biopsies that were performed in outpatients from October 2006 to July 2010. The liver biopsies were performed following one-night fasting using the tru-cut biopsy gun (18-20 gauge) after marking the best seen and hypovascular part of the liver, distant enough from the adjacent organs. A total of 1018 patients were referred to our radiology department. Most of the patients had hepatitis B (60.6%). The biopsy specimens were recorded and sent to our pathology department for histopathological examination. According to the results of our series, percutaneous liver biopsy using the tru-cut biopsy gun guided by ultrasonography can be performed safely. We resolve that routine ultrasound of the puncture site is a quick, effective and safe procedure. The complication rate is very low. The US-assisted percutaneous liver biopsy should be used for all cases

  5. The usefulness of S100P, mesothelin, fascin, prostate stem cell antigen, and 14-3-3 sigma in diagnosing pancreatic adenocarcinoma in cytological specimens obtained by endoscopic ultrasound guided fine-needle aspiration.

    Science.gov (United States)

    Dim, Daniel C; Jiang, Feng; Qiu, Qi; Li, Ting; Darwin, Peter; Rodgers, William H; Peng, Hong Qi

    2014-03-01

    Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) of the pancreas is an efficient and minimally invasive procedure for the diagnosis and staging of pancreatic adenocarcinoma. Because of some limitations of EUS-FNA in diagnosis of well-differentiated or early stage cancers, the purpose of this study is to assess the added benefit of immunohistochemistry. We studied five proteins overexpressed in pancreatic adenocarcinoma, namely, prostate stem cell antigen, fascin, 14-3-3 sigma, mesothelin and S100P utilizing immunohistochemistry on paraffin sections from cellblocks obtained by EUS-FNA. Sixty-two cases of EUS-FNA of the pancreas that had follow-up histological and/or clinical diagnosis and sufficient material in cell blocks were included. Using histological diagnosis and/or clinical outcome as the reference standard, EUS-FNA shows the highest sensitivity (95%) and specificity (91%) and is superior to any marker in this study. Among five antibodies, S100P reveals the best diagnostic characters showing 90% of sensitivity and 67% of specificity. Fascin shows high specificity (92%) but low sensitivity (38%). Mesothelin has a moderate sensitivity (74%) and low specificity (33%), PSCA and 14-3-3 show high sensitivity but zero specificity. S100P and mesothelin were useful in nine indeterminate cases. S100P correctly predicted six of seven cancers and one of one without cancer and mesothelin correctly diagnosed five of seven cancers and one of two noncancers in this group. EUS-FNA cytomorphology is superior to any of the immunohistochemical markers used in this study. Use of S100P and mesothelin in cytologically borderline cases can increase the diagnostic accuracy in this group. Copyright © 2011 Wiley Periodicals, Inc., A Wiley Company.

  6. Benefits of early biopsy on the outcome of kidney transplantation.

    Science.gov (United States)

    Dominguez, J; Kompatzki, A; Norambuena, R; Arenas, J; Dell'Oro, A; Bustamante, A; Pinochet, R; Cabello, J M; Alvarez, S; Pais, E; Llanos, R; Cortes-Monroy, G

    2005-10-01

    Delayed graft function has been associated with worse long-term kidney allograft survival. Adequate diagnosis of the etiology of dysfunction is crucial, often requiring routine early biopsies. The aim of this article was to report the results and safety of early kidney allograft biopsies and how they influenced its management. Between September 1994 and July 2004, 134 renal transplant recipients were prescribed cyclosporine (CsA; Neoral, Novartis, Chile), steroids, and a third agent (azathioprine in 92% of the graft recipients). Thirty-four patients (26%) had a kidney biopsy performed within the first week because of allograft dysfunction. The main diagnosis was acute tubular necrosis (ATN) in 22 patients (65%), whereas 6 (18%) were diagnosed with an acute rejection episode (ARE), allowing prompt initiation of therapy with reversal of rejection in 4 of them. Two patients (6%) showed signs of thrombotic microangiopathy (TMA) induced by CsA, which subsided following a switch from CsA to tacrolimus (Prograf Pharmainvesti, Chile). In 2 patients, the biopsy specimen showed signs of CsA nephrotoxicity that reverted following dose reduction. Finally, in 2 patients, the biopsy specimen showed chronic nephropathy of donor origin, which had not been previously recognized, resulting in graft loss. There was only one major complication related to the biopsy, intraperitoneal bleeding that required surgical treatment. Early allograft biopsy is safe and, in a significant number of cases (30%), it detects important allograft pathology (ARE, TMA, and drug toxicity), which when adequately and promptly treated may rescue the graft.

  7. No need for biopsies

    DEFF Research Database (Denmark)

    Gjødsbøl, Kristine; Skindersoe, Mette E; Christensen, Jens Jørgen

    2011-01-01

    The aim of the study was to compare three sampling techniques used in routine diagnostics to identify the microbiota in chronic venous leg ulcers. A total of 46 patients with persisting venous leg ulcers were included in the study. At inclusion, swab, biopsy and filter paper pad samples were...... collected. After 4 weeks, additional biopsy and filter paper pad samples were collected. Bacteria were isolated and identified at species level by standard methods. The most common bacterial species detected was Staphylococcus aureus found in 89% of the ulcers. No methicillin-resistant S. aureus isolates...

  8. Consistent and reproducible outcomes of blastocyst biopsy and aneuploidy screening across different biopsy practitioners: a multicentre study involving 2586 embryo biopsies.

    Science.gov (United States)

    Capalbo, Antonio; Ubaldi, Filippo Maria; Cimadomo, Danilo; Maggiulli, Roberta; Patassini, Cristina; Dusi, Ludovica; Sanges, Federica; Buffo, Laura; Venturella, Roberta; Rienzi, Laura

    2016-01-01

    Is blastocyst biopsy and quantitative real-time PCR based comprehensive chromosome screening a consistent and reproducible approach across different biopsy practitioners? The blastocyst biopsy approach provides highly consistent and reproducible laboratory and clinical outcomes across multiple practitioners from different IVF centres when all of the embryologists received identical training and use similar equipment. Recently there has been a trend towards trophectoderm (TE) biopsy in preimplantation genetic screening (PGS)/preimplantation genetic diagnosis (PGD) programmes. However, there is still a lack of knowledge about the reproducibility that can be obtained from multiple biopsy practitioners in different IVF centres in relation also to blastocysts of different morphology. Although it has been demonstrated that biopsy at the blastocyst stage has no impact on embryo viability, it remains a possibility that less experienced individual biopsy practitioners or laboratories performing TE biopsy may affect certain outcomes. We investigated whether TE biopsy practitioners can have an impact on the quality of the genetic test and the subsequent clinical outcomes. This longitudinal cohort study, between April 2013 and December 2014, involved 2586 consecutive blastocyst biopsies performed at three different IVF centres and the analysis of 494 single frozen euploid embryo transfer cycles (FEET). Seven biopsy practitioners performed the blastocyst biopsies in the study period and quantitative PCR was used for comprehensive chromosome screening (CCS). The same practitioner performed both the biopsy and tubing procedures for each blastocyst they biopsied. To investigate the quality of the biopsied samples, the diagnostic rate, sample-specific concurrence and the cell number retrieved in the biopsy were evaluated for each biopsy operator. Clinical outcomes following FEET cycles were stratified by biopsy operator and compared. Cellularity of the biopsy sample was also

  9. MRI-Guided Percutaneous Biopsy of Mediastinal Masses Using a Large Bore Magnet: Technical Feasibility

    Energy Technology Data Exchange (ETDEWEB)

    Garnon, J., E-mail: juliengarnon@gmail.com [Nouvel Hôpital Civil, Department of Interventional Radiology (France); Ramamurthy, N., E-mail: nitin-ramamurthy@hotmail.com [Norfolk and Norwich University Hospital, Department of Radiology (United Kingdom); Caudrelier J, J., E-mail: caudjean@yahoo.fr [Nouvel Hôpital Civil, Department of Interventional Radiology (France); Erceg, G., E-mail: erceggorislav@yahoo.com; Breton, E., E-mail: ebreton@unistra.fr [ICube, University of Strasbourg, CNRS (France); Tsoumakidou, G., E-mail: gtsoumakidou@yahoo.com; Rao, P., E-mail: pramodrao@me.com; Gangi, A., E-mail: gangi@unistra.fr [Nouvel Hôpital Civil, Department of Interventional Radiology (France)

    2016-05-15

    ObjectiveTo evaluate the diagnostic accuracy and safety of magnetic resonance imaging (MRI)-guided percutaneous biopsy of mediastinal masses performed using a wide-bore high-field scanner.Materials and MethodsThis is a retrospective study of 16 consecutive patients (8 male, 8 female; mean age 74 years) who underwent MRI-guided core needle biopsy of a mediastinal mass between February 2010 and January 2014. Size and location of lesion, approach taken, time for needle placement, overall duration of procedure, and post-procedural complications were evaluated. Technical success rates and correlation with surgical pathology (where available) were assessed.ResultsTarget lesions were located in the anterior (n = 13), middle (n = 2), and posterior mediastinum (n = 1), respectively. Mean size was 7.2 cm (range 3.6–11 cm). Average time for needle placement was 9.4 min (range 3–18 min); average duration of entire procedure was 42 min (range 27–62 min). 2–5 core samples were obtained from each lesion (mean 2.6). Technical success rate was 100 %, with specimens successfully obtained in all 16 patients. There were no immediate complications. Histopathology revealed malignancy in 12 cases (4 of which were surgically confirmed), benign lesions in 3 cases (1 of which was false negative following surgical resection), and one inconclusive specimen (treated as inaccurate since repeat CT-guided biopsy demonstrated thymic hyperplasia). Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy in our study were 92.3, 100, 100, 66.7, and 87.5 %, respectively.ConclusionMRI-guided mediastinal biopsy is a safe procedure with high diagnostic accuracy, which may offer a non-ionizing alternative to CT guidance.

  10. Tangential Biopsy Thickness versus Lesion Depth in Longitudinal Melanonychia: A Pilot Study

    Directory of Open Access Journals (Sweden)

    Nilton Di Chiacchio

    2012-01-01

    Full Text Available Longitudinal melanonychia can be caused by melanocyte activation (hypermelanosis or proliferation (lentigo, nevus or melanoma. Histopathologic examination is mandatory for suspicious cases of melanomas. Tangential biopsy of the matrix is an elegant technique avoiding nail plate dystrophy, but it was unknown whether the depth of the sample obtained by this method is adequate for histopathologic diagnosis. Twenty-two patients with longitudinal melanonychia striata were submitted to tangential matrix biopsies described by Haneke. The tissue was stained with hematoxylin-eosin and the specimens were measured at 3 distinct points according to the total thickness: largest (A, intermediate (B and narrowest (C then divided into 4 groups according to the histopathologic diagnosis (G1: hypermelanosis; G2: lentigos; G3: nevus; G4: melanoma. The lesions were measured using the same method. The mean specimen/lesion thickness measure values for each group was: G1: 0,59/0,10 mm, G2: 0,67/0,08 mm, G3: 0,52/0,05 mm, G4: 0,58/0,10 mm. The general average thickness for all the specimens/lesions was 0,59/0,08 mm. We concluded that the tangential excision, for longitudinal melanonychia, provides an adequate material for histopathological diagnosis.

  11. Breast biopsy - stereotactic

    Science.gov (United States)

    The provider will ask about your medical history. A breast exam may be done. If you take medicines (including aspirin, supplements, or herbs), ask your doctor whether you need to stop taking these before the biopsy. Tell your doctor if you may be ...

  12. Closed Pericardial Biopsy

    African Journals Online (AJOL)

    1974-09-28

    Sep 28, 1974 ... The instrument used is a hook biopsy needle (Fig. I). manufactured by Becton, Dickinson and Co., Rutherford,. New Jersey, USA. The instrument' and technique' will be reviewed. The instrument consists of an ll-gauge needle with a sharp cutting edge into which fits, interchangeably, a 13-gauge needle or a ...

  13. Lung needle biopsy

    Science.gov (United States)

    ... if you have certain lung diseases such as emphysema. Usually, a collapsed lung after a biopsy does not need treatment. But ... any type Bullae (enlarged alveoli that occur with emphysema) Cor pulmonale (condition ... of the lung High blood pressure in the lung arteries Severe ...

  14. No need for biopsies

    DEFF Research Database (Denmark)

    Gjødsbøl, Kristine; Skindersoe, Mette E; Christensen, Jens Jørgen

    2011-01-01

    The aim of the study was to compare three sampling techniques used in routine diagnostics to identify the microbiota in chronic venous leg ulcers. A total of 46 patients with persisting venous leg ulcers were included in the study. At inclusion, swab, biopsy and filter paper pad samples were coll...

  15. Open pleural biopsy

    Science.gov (United States)

    An open pleural biopsy is done in the hospital using general anesthesia . This means you will be asleep and pain-free. A tube will be placed through your mouth down your throat to help you breathe. The surgery is done in ...

  16. Axial-Gap Induction Motor For Levitated Specimens

    Science.gov (United States)

    Sridharan, Govind; Rhim, Won-Kyu; Barber, Dan; Chung, Sang

    1992-01-01

    Motor does not obscure view of specimen. Axial-gap induction motor applies torque to rotate electrostatically or electromagnetically levitated specimen of metal. Possible applications include turning specimens for uniform heating under focused laser beams and obtaining indirect measurements of resistivities or of surface tensions in molten specimens.

  17. Effectiveness of combined use of imprint cytological and histological examination in CT-guided tissue-core biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Yamagami, Takuji; Yoshimatsu, Rika; Kajiwara, Kenji; Ishikawa, Masaki; Awai, Kazuo [Hiroshima University, Department of Diagnostic Radiology, Institute and Graduate School of Biomedical Sciences, Minami-Ku, Hiroshima (Japan); Matsumoto, Tomohiro; Hasebe, Terumitsu [Tokai University Hachioji Hospital, Tokai University School of Medicine, Department of Radiology, Hachioji, Tokyo (Japan); Kakizawa, Hideaki [Hiroshima University, Department of Diagnostic Radiology, Institute and Graduate School of Biomedical Sciences, Minami-Ku, Hiroshima (Japan); Hiroshima Red Cross Hospital and Atomic-bomb Survivors Hospital, Department of Diagnostic Radiology, Naka-Ku, Hiroshima (Japan); Toyoda, Naoyuki [Hiroshima University, Department of Diagnostic Radiology, Institute and Graduate School of Biomedical Sciences, Minami-Ku, Hiroshima (Japan); National Hospital Organisation Kure Medical Centre, Department of Diagnostic Radiology, Kure, Hiroshima (Japan)

    2014-05-15

    This study evaluated the efficacy of the combination of imprint cytology and histology in tissue-core percutaneous biopsy under real-time computed tomography (CT) fluoroscopic guidance. Between October 2009 and June 2013, 156 percutaneous needle biopsies were performed in our institution. Those obtained by tissue-core biopsy underwent both imprint cytological and histological examinations routinely after touch imprint cytology was performed on site to evaluate the samples' sufficiency for cytological and pathological examination. Final diagnosis was confirmed by independent surgical pathology, independent culture results or clinical follow-up. Rates of adequate specimens and precise diagnosis, by combined cytological and histological examination were 100 % (156/156) and 96.2 % (150/156), by cytology 94.4 % (152/156) and 83.3 % (130/156) and by histology 99.3 % (155/156) and 92.3 % (144/156). Precise diagnosis was achieved by combined examinations in 94.7 % (89/94) of thoracic lesions, 97.6 % (40/41) of musculoskeletal lesions, and 100 % (21/21) of abdominal, pelvic and retroperitoneal lesions. In all 104 lesions diagnosed as malignant by CT-guided biopsy and in 30 of 52 diagnosed as benign, specific cell types could be proved by combined examinations. Combined imprint cytology and histology performed after on-site touch imprint cytological evaluation improved the diagnostic ability of CT fluoroscopically guided biopsy. (orig.)

  18. [A transportation vehicle for laparoscopically obtained follicular specimens].

    Science.gov (United States)

    Fliess, F R; Sudik, R

    1984-01-01

    Structure, function and first results with a vehicle for transportation were described. This apparatus allows to store laparoscopic harvested follicular fluids for a while in constant temperature and in air condition with 5% CO2 in compressed air. Simultaneously the follicular fluids were transported in this vehicle from operating theatre to the laboratory.

  19. Bacteriology of urine specimens obtained from men with ...

    African Journals Online (AJOL)

    Background: Bacteriuria and urinary tract infections are common sequelae of benign prostatic hyperplasia (BPH). Thus, the knowledge of urine bacteriology in men with symptomatic BPH in our environment may play a complementary role in management. Objectives: To determine the incidence of bacteriuria and the ...

  20. Recommendations for processing cardiovascular surgical pathology specimens: a consensus statement from the Standards and Definitions Committee of the Society for Cardiovascular Pathology and the Association for European Cardiovascular Pathology

    NARCIS (Netherlands)

    Stone, James R.; Basso, Cristina; Baandrup, Ulrik T.; Bruneval, Patrick; Butany, Jagdish; Gallagher, Patrick J.; Halushka, Marc K.; Miller, Dylan V.; Padera, Robert F.; Radio, Stanley J.; Sheppard, Mary N.; Suvarna, Kim; Tan, Carmela D.; Thiene, Gaetano; van der Wal, Allard C.; Veinot, John P.

    2012-01-01

    With the advent of molecular subclassification of diseases, much consideration should be given to the proper processing of cardiovascular surgical pathology specimens to maximize patient care. Such specimens include endomyocardial biopsies, cardiac myectomy specimens, cardiac apical core segments,

  1. Development of miniature bending fatigue specimens

    International Nuclear Information System (INIS)

    Rao, G.R.; Chin, B.A.; Rowcliffe, A.

    1991-01-01

    Two new miniaturized bending fatigue specimens have been designed and developed to aid in the scoping of materials for fusion first-wall and blanket structural applications. One of these is rectangular in shape with a gauge section 6.35 mm in length, while the other is cut from a 3 mm transmission electron microscopy (TEM) disk and has a gauge length of 1.5 mm. Test rules for unirradiated annealed type 316 stainless steel tested at room temperature, 550deg C and 650deg C are presented. A good correlation between miniature and standard subsize fatigue specimen results was obtained. The miniature specimen results show the same dependence of strain range on cycles to failure as the standard subsize specimens with the miniature-disk specimen results falling below all the other results. The results indicate that these specimens provide reliable data that can be used to scope fatigue properties for fusion applications. (orig.)

  2. CT Guided Bone Biopsy Using a Battery Powered Intraosseous Device

    Energy Technology Data Exchange (ETDEWEB)

    Schnapauff, Dirk, E-mail: dirk.schnapauff@charite.de; Marnitz, Tim, E-mail: tim.marnitz@charite.de; Freyhardt, Patrick, E-mail: Patrick.freyhardt@charite.de; Collettini, Federico, E-mail: Federico.collettini@charite.de [Charite Universitaetsmedizin Berlin, Campus Virchow-Klinikum, Department of Radiology (Germany); Hartwig, Kerstin, E-mail: kerstin.hartwig@charite.de [Charite Universitaetsmedizin Berlin, Campus Charite Mitte, Department of Haematology and Oncology (Germany); Joehrens, Korinna, E-mail: korinna.joehrens@charite.de [Charite Universitaetsmedizin Berlin, Campus Charite Mitte, Department of Pathology (Germany); Hamm, Bernd, E-mail: bernd.hamm@charite.de; Kroencke, Thomas, E-mail: thomas.kroencke@charite.de; Gebauer, Bernhard, E-mail: Bernhard.gebauer@charite.de [Charite Universitaetsmedizin Berlin, Campus Virchow-Klinikum, Department of Radiology (Germany)

    2013-10-15

    Purpose: To evaluate the feasibility of a battery powered intraosseous device to perform CT-fluoroscopy guided bone biopsy. Methods: Retrospective analysis of 12 patients in whom bone specimen were acquired from different locations under CT-fluoroscopy guidance using the OnControl bone marrow biopsy system (OBM, Vidacare, Shavano Park, TX, USA). Data of the 12 were compared to a historic cohort in whom the specimen were acquired using the classic Jamshidi Needle, as reference needle using manual force for biopsy. Results: Technical success was reached in 11 of 12 cases, indicated by central localisation of the needle within the target lesion. All specimen sampled were sufficient for histopathological workup. Compared to the historical cohort the time needed for biopsy decreased significantly from 13 {+-} 6 to 6 {+-} 4 min (P = 0.0001). Due to the shortened intervention time the radiation dose (CTDI) during CT-fluoroscopy was lowered significantly from 169 {+-} 87 to 111 {+-} 54 mGy Multiplication-Sign cm (P = 0.0001). Interventional radiologists were confident with the performance of the needle especially when using in sclerotic or osteoblastic lesions. Conclusion: The OBM is an attractive support for CT-fluoroscopy guided bone biopsy which is safe tool and compared to the classical approach using the Jamshidi needle leading to significantly reduced intervention time and radiation exposure.

  3. Dysplastic naevi: to shave, or not to shave? A retrospective study of the use of the shave biopsy technique in the initial management of dysplastic naevi.

    Science.gov (United States)

    Armour, Katherine; Mann, Stephen; Lee, Stephen

    2005-05-01

    The management of dysplastic naevi is a controversial subject. This study sought to assess the usefulness of the shave biopsy technique in the initial management of dysplastic naevi, and to demonstrate the advantages over the punch biopsy technique. We report a retrospective observational study of histopathology specimens examined in one histopathology practice over a 14-month period. Patients who had a clinical diagnosis of 'dysplastic naevus', which had initially been biopsied using either a shave or punch biopsy, and then followed up with a full-thickness elliptical excision, were included in the study. Histopathological concordance between the shave and punch biopsy specimens and their respective follow-up elliptical excisions was compared. We found that 21 of 22 (95.5%) shave biopsies were concordant with their respective excision specimens, and that 29 of 41 (70.7%) punch biopsies were concordant with their respective elliptical excision specimens. Of the shave biopsy specimens reviewed, 66% showed that the dysplastic naevi were completely excised with the initial biopsy, compared with 21.2% of the punch biopsy specimens. These findings confirm that shave biopsies provide accurate diagnostic information in the assessment of dysplastic naevi. Shave biopsies enable the entire lesion to be submitted for histopathological assessment, improving the chances of an accurate diagnosis.

  4. Percutaneous lung biopsy after pneumonectomy: factors for improving success in the care of patients at high risk.

    Science.gov (United States)

    Cronin, Carmel G; Sharma, Amita; Digumarthy, Subba R; Gilman, Mathew D; McLoud, Theresa; Muse, Victorine V; Shepard, Joanne O

    2011-04-01

    The purpose of this study was to assess the risks and complications of CT-guided needle biopsy of lung nodules in patients with a single lung after pneumonectomy. A database search for the records of patients who had undergone lung biopsy over a 9-year period revealed that 1771 patients had done so. Fourteen (0.7%) of these patients (11 men, three women; mean age, 63 years; range, 42.4-79.6 years) had undergone pneumonectomy and been referred for biopsy of the contralateral lung. The images and medical records of these patients were reviewed in detail. Lung biopsy was technically successful in 86% (12/14) of cases. All procedures were fine-needle aspiration, and a core biopsy specimen also was obtained in one case. Fifty percent (6/12) of the procedures were performed with local anesthesia alone and 50% with a combination of local anesthesia and conscious sedation. The pneumothorax rate was 25% (3/12). All pneumothoraces were small and asymptomatic, and none required a chest drain. There were no cases of hemoptysis. No other immediate or delayed complications were encountered. Malignancy was found in 83% (10/12) of cases. In one of the other two cases (8%) the result was false-negative, and in the other, the nodules resolved without chemotherapy and were presumed to be inflammatory. Percutaneous lung biopsy performed on the single lung in patients who have undergone pneumonectomy is feasible and successful. Lung biopsy in these circumstances should be performed by an experienced radiologist with thoracic surgical backup.

  5. Endometrial Biopsy and Hystopathological Diagnosis - A 10 year ...

    African Journals Online (AJOL)

    Background: Appropriate diagnosis is the mainstay of proper and effective management. For an appropriate histopathological diagnosis to be made, an accurate record of clinical details including sex is essential. The completeness or otherwise of data supplied by clinicians submitting endometrial biopsy specimen was ...

  6. Prevalence Of Helicobacter pylori In Gastric Biopsies Of Patients ...

    African Journals Online (AJOL)

    The prevalence of Helicobacter pylori infection as seen at the University of Benin Teaching Hospital (UBTH) Benin City Nigeria was 16% which was significant using the students T-test (P<0.05). Eighty one gastric biopsy specimens received in the microbiology laboratory were cultured on chocolate agar. Of the H. pylori ...

  7. Percutaneous CT-guided needle biopsies of musculoskeletal tumors: a 5-year analysis of non-diagnostic biopsies

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Connie Y.; Huang, Ambrose J.; Bredella, Miriam A.; Torriani, Martin; Rosenthal, Daniel I. [Massachusetts General Hospital, Division of Musculoskeletal Imaging and Intervention, Department of Radiology, Boston, MA (United States); Halpern, Elkan F. [Massachusetts General Hospital, Institute for Technology Assessment, Department of Radiology, Boston, MA (United States); Springfield, Dempsey S. [Massachusetts General Hospital, Department of Orthopedics, Boston, MA (United States)

    2015-12-15

    To study non-diagnostic CT-guided musculoskeletal biopsies and take steps to minimize them. Specifically we asked: (1) What malignant diagnoses have a higher non-diagnostic rate? (2) What factors of a non-diagnostic biopsy may warrant more aggressive pursuit? (3) Do intra-procedural frozen pathology (FP) or point-of-care (POC) cytology reduce the non-diagnostic biopsy rate ?This study was IRB-approved and HIPAA-compliant. We retrospectively reviewed 963 consecutive CT-guided musculoskeletal biopsies. We categorized pathology results as malignant, benign, or non-diagnostic and recorded use of FP or POC cytology. Initial biopsy indication, final diagnosis, method of obtaining the final diagnosis of non-diagnostic biopsies, age of the patient, and years of biopsy attending experience were recorded. Groups were compared using Pearson's χ{sup 2} test or Fisher's exact test. In all, 140 of 963 (15 %) biopsies were non-diagnostic. Lymphoma resulted in more non-diagnostic biopsies (P < 0.0001). While 67% of non-diagnostic biopsies yielded benign diagnoses, 33% yielded malignant diagnoses. Patients whose percutaneous biopsy was indicated due to the clinical context without malignancy history almost always generated benign results (96 %). Whereas 56% of biopsies whose indication was an imaging finding of a treatable lesion were malignant, 20% of biopsies whose indication was a history of malignancy were malignant. There was no statistically significant difference in the nondiagnostic biopsy rates of pediatric versus adult patients (P = 0.8) and of biopsy attendings with fewer versus more years of experience (P = 0.5). The non-diagnostic rates of biopsies with FP (8 %), POC cytology (25 %), or neither (24 %) were significantly different (P < 0.0001). Lymphoma is the malignant diagnosis most likely to result in a non-diagnostic biopsy. If the clinical and radiologic suspicion for malignancy is high, repeat biopsy is warranted. If the clinical context suggests a

  8. Computed tomography-guided percutaneous biopsy of pancreatic masses using pneumodissection

    Directory of Open Access Journals (Sweden)

    Chiang Jeng Tyng

    2013-06-01

    Full Text Available Objective To describe the technique of computed tomography-guided percutaneous biopsy of pancreatic tumors with pneumodissection. Materials and Methods In the period from June 2011 to May 2012, seven computed tomography-guided percutaneous biopsies of pancreatic tumors utilizing pneumodissection were performed in the authors' institution. All the procedures were performed with an automatic biopsy gun and coaxial system with Tru-core needles. The biopsy specimens were histologically assessed. Results In all the cases the pancreatic mass could not be directly approached by computed tomography without passing through major organs and structures. The injection of air allowed the displacement of adjacent structures and creation of a safe coaxial needle pathway toward the lesion. Biopsy was successfully performed in all the cases, yielding appropriate specimens for pathological analysis. Conclusion Pneumodissection is a safe, inexpensive and technically easy approach to perform percutaneous biopsy in selected cases where direct access to the pancreatic tumor is not feasible.

  9. Computed tomography-guided percutaneous biopsy of pancreatic masses using pneumodissection

    International Nuclear Information System (INIS)

    Tyng, Chiang Jeng; Bitencourt, Almir Galvao Vieira; Almeida, Maria Fernanda Arruda; Barbosa, Paula Nicole Vieira; Martins, Eduardo Bruno Lobato; Junior, Joao Paulo Kawaoka Matushita; Chojniak, Rubens; Coimbra, Felipe Jose Fernandez

    2013-01-01

    Objective: to describe the technique of computed tomography-guided percutaneous biopsy of pancreatic tumors with pneumodissection. Materials and methods: in the period from June 2011 to May 2012, seven computed tomography guided percutaneous biopsies of pancreatic tumors utilizing pneumodissection were performed in the authors' institution. All the procedures were performed with an automatic biopsy gun and coaxial system with Tru-core needles. The biopsy specimens were histologically assessed. Results: in all the cases the pancreatic mass could not be directly approached by computed tomography without passing through major organs and structures. The injection of air allowed the displacement of adjacent structures and creation of a safe coaxial needle pathway toward the lesion. Biopsy was successfully performed in all the cases, yielding appropriate specimens for pathological analysis. Conclusion: Pneumodissection is a safe, inexpensive and technically easy approach to perform percutaneous biopsy in selected cases where direct access to the pancreatic tumor is not feasible. (author)

  10. Oral Biopsy: A Dental Gawk

    African Journals Online (AJOL)

    Oral Biopsy: A Dental Gawk. Sir,. Dermatologists are often confronted with neoplasms ... the use of a needle, biopsy punch, biopsy forceps, laser, or electrocautery device. Needles may be appropriate in ... so widespread in dental practice––fundamentally because of a lack of awareness of the procedure among dental.

  11. Observer variation and discriminatory value of biopsy features in inflammatory bowel disease.

    OpenAIRE

    Theodossi, A; Spiegelhalter, D J; Jass, J; Firth, J; Dixon, M; Leader, M; Levison, D A; Lindley, R; Filipe, I; Price, A

    1994-01-01

    If skilled histopathologists disagree over the same biopsy specimen, at least one must have an incorrect interpretation. Thus, disagreement is associated with, although not the cause of, diagnostic error. The present study aimed to determine the magnitude of variation among 10 observers with a special interest in gastrointestinal histopathology. They independently interpreted the same biopsy specimens for morphological features which may discriminate between patients with Crohn's disease and ...

  12. Prostate needle biopsies: interobserver variation and clinical consequences of histopathological re-evaluation

    DEFF Research Database (Denmark)

    Berg, Kasper Drimer; Toft, Birgitte Grønkaer; Røder, Martin Andreas

    2011-01-01

    -evaluations in 19.7% and 13.1% of patients, respectively. Gleason scoring based on the radical prostatectomy specimen was higher than in both primary reports and re-evaluation of biopsies. Although a relatively high degree of concordance was found between biopsy assessments, the significant trend towards higher...

  13. Novel modified Ussing chamber for the study of absorption and secretion in human endoscopic biopsies

    DEFF Research Database (Denmark)

    Larsen, R; Mertz-Nielsen, A; Hansen, M B

    2001-01-01

    The aim of this study was to design and evaluate a modified Ussing chamber, that makes use of constant air suction (modified Ussing air suction chamber, MUAS) for fixation of biopsy specimens. Standard size forceps biopsies were taken from the descending part of duodenum from patients undergoing ...

  14. Discrepancies between biopsy-based and excision-based grading of cervical intraepithelial neoplasia: the important role of time between excision and biopsy.

    Science.gov (United States)

    Zhang, Lu; Li, Qiang; Zhao, Mingyu; Jia, Lin; Zhang, Youzhong

    2015-05-01

    We sought to evaluate the rate of cervical intraepithelial neoplasia (CIN) ≤ 1 in loop electrosurgical excision procedure (LEEP) specimens after the treatment of biopsy-proven CIN 2-3, and to identify factors that are associated with the rate of CIN ≤ 1, especially focusing on the time interval between biopsy and LEEP. The goal of this research is to reduce the overtreatment of women with CIN 2-3. This was a retrospective study performed on women undergoing LEEP for biopsy-proven CIN 2-3 in Qilu hospital in Shandong, China. Patients were separated according to LEEP pathology (CIN ≤ 1 vs. CIN 2-3), and compared using the χ2 test and Student t test. The main outcome measures were pathologic discrepancy (defined as CIN 2-3 at biopsy, but CIN ≤ 1 at excision). Of the 391 women with biopsy-proven CIN 2-3, 26.9% had LEEP specimens with CIN ≤ 1 histologies. The likelihood of a CIN ≤ 1 LEEP specimen increases for greater biopsy-LEEP intervals (odds ratio, 1.374; 95% confidence interval, 1.089-1.735; P = 0.008). Cases in younger women and biopsy-assessed CIN 2 cases were both more likely to have CIN 1 or negative LEEP specimens. The rate of spontaneous histologic regression (defined as CIN ≤ 1 at resection) was 26.9%. These low-grade lesions were more common in LEEP specimens from young women with CIN 2 at biopsy, and who underwent LEEP later after the initial biopsy.

  15. Histopathological of lymph node biopsies in Lagos, South West ...

    African Journals Online (AJOL)

    The demographic data regarding age, sex, provisional diagnosis and site of biopsy were obtained from request forms. The data were analysed using the Statistical Package for Social Science version 21. There were 123 lymph node biopsies seen during the study period with age range of 1- 78 years and male to female ...

  16. CT‑guided percutaneous transthoracic lung biopsy: First experience ...

    African Journals Online (AJOL)

    Percutaneous lung biopsy had been described in the nineteenth century by Leyden, but image- guided needle chest biopsy only gained widespread acceptance in the 1970s. Currently, tissue sampling of a thoracic lesion is indicated when the diagnosis cannot be obtained by the non-invasive techniques and cytological ...

  17. Prostate biopsy techniques and indications: when, where, and how?

    Science.gov (United States)

    Scherr, Douglas S; Eastham, James; Ohori, Makoto; Scardino, Peter T

    2002-02-01

    Transrectal ultrasound (TRUS) and prostate biopsy have become one of the most common office-based procedures for the practicing urologist. During the past 50 years, the techniques, indications, and pathologic interpretation of prostate biopsies have evolved. The abandonment of blind finger-guided needle biopsies in favor of systematic TRUS-guided biopsies epitomizes much of this change. Similarly, the indications for prostate biopsy have become more refined. In the past, the presence of a prostatic nodule on digital rectal examination (DRE) was the primary indication for biopsy until the introduction of prostatic-specific antigen (PSA) in the 1980s and its widespread use for prostate cancer screening. Abnormalities of PSA or its derivatives now represent the most common indication for prostate biopsy. Although TRUS initially began as a tool to direct needles into various locations within the prostate, today a great deal of information can be obtained from prostate ultrasound for the discerning clinician. As such, TRUS-guided biopsy of the prostate has become an important staging and diagnostic tool for the practicing urologist. Here we review the current techniques and indications as well as pertinent pathologic and staging data obtained through TRUS and prostate biopsy. Copyright 2002 by W.B. Saunders Company

  18. Transjugular renal biopsy in a case of nephrotic syndrome with extrahepatic portal venous obstruction

    Directory of Open Access Journals (Sweden)

    N Siddiqi

    2013-01-01

    Full Text Available Renal biopsy in patients with nephrotic syndrome helps to establish the pathological diagnosis and subsequent treatment. In certain circumstances, biopsies are difficult to obtain because of the risk of bleeding. We report a case where renal biopsy was obtained through the transjugular route in a patient who had nephrotic syndrome with extrahepatic portal venous obstruction.

  19. Endometrial biopsy findings in postmenopausal bleeding

    International Nuclear Information System (INIS)

    Sarfraz, T.; Tariq, H.

    2007-01-01

    To study endometrial histopathology in women presenting with postmenopausal bleeding. A two-year study from January 2003 to December 2004 of 100 cases of postmenopausal bleeding was conducted at Combined Military Hospital, Sialkot. The histopathology of endometrial biopsy specimens was done to find out the causes of postmenopausal bleeding in these ladies. All these 100 patients had confirmed menopause and the average age was 55 years and above. The most common histopathological diagnosis was senile endometrial atrophy (27%), followed by simple cystic hyperplasia in (17%). Three cases of simple cystic hyperplasia had coexistent ovarian tumors. Glandular hyperplasia without atypia was seen in 6% and with atypia in 4%. Other causes were endometritis (13%), endometrial polyps (8%), proliferative phase endometrium (6%) and secretary phase endometrium (5%). Endometrial carcinoma was seen in (6%) cases, (8%) biopsy specimens were non-representative. Although senile endometrial atrophy was most commonly found in these ladies but a significant percentage of endometrial hyperplasia and endometrial cancer implies the need for investigating all cases of postmenopausal bleeding. Bimanual examination and pelvic ultrasonography should be combined with endometrial sampling so that rare pelvic pathologies may not be missed. (author)

  20. Video-assisted thoracoscopic lung biopsy in the diagnosis of interstitial lung disease: a prospective, multi-center study in 224 patients.

    Science.gov (United States)

    Fibla, Juan J; Molins, Laureano; Blanco, Ana; Royo, Iñigo; Martínez Vallina, Primitivo; Martínez, Néstor; García Barajas, Santiago; Gomez, Ana; Estors, Miriam; Moldes, Milagros; Fernández, Esther; Xaubet, Antoni

    2012-03-01

    To evaluate whether the location and number of lung biopsies obtained by video-assisted thoracoscopy (VAT) influence the diagnosis of diffuse interstitial lung disease (ILD). To assess the applicability of an Ambulatory Surgery Program (ASP). Prospective, multicenter study of VAT lung biopsies due to suspected ILD from January 2007 to December 2009, including 224 patients from 13 Spanish centers (mean age 57.1 years; 52.6% females). Data were prospectively collected in every institution and sent to the coordination center for analysis. The most affected areas in high resolution chest CT were the lower lobes (55%). Bronchoscopy was performed in 84% and transbronchial biopsy in 49.1%. In 179 cases (79.9%), more than one biopsy was performed, with a diagnostic agreement of 97.2%. A definitive histopathologic diagnosis was obtained in 195 patients (87%). Idiopathic pulmonary fibrosis was the most frequent diagnosis (26%). There were no statistically significant factors that could predict a greater diagnostic yield (neither anatomical location nor number of biopsies). Seventy patients (31.3%) were included in an ASP. After discharge, there were complications in 12 patients (5.4%), similar between patients admitted postoperatively (9/154: 5.8%) and those included in an ASP (3/70: 4.3%). Anatomical location and number of lung biopsy specimens did not seem to influence the diagnosis. The patients included in an ASP had a complication rate comparable to that of the hospitalized, so this procedure can be included in a surgical outpatient program. Lung biopsy obtained by VAT is a powerful and safe tool for diagnosis of suspected ILD, resulting in a definitive diagnosis for the majority of patients with a low morbidity rate. Copyright © 2011 SEPAR. Published by Elsevier Espana. All rights reserved.

  1. Preserve specimens for reproducibility

    Czech Academy of Sciences Publication Activity Database

    Krell, F.-T.; Klimeš, Petr; Rocha, L. A.; Fikáček, M.; Miller, S. E.

    2016-01-01

    Roč. 539, č. 7628 (2016), s. 168 ISSN 0028-0836 Institutional support: RVO:60077344 Keywords : reproducibility * specimen * biodiversity Subject RIV: EH - Ecology, Behaviour Impact factor: 40.137, year: 2016 http://www.nature.com/nature/journal/v539/n7628/full/539168b.html

  2. A Comparison of Transjugular and Plugged-Percutaneous Liver Biopsy in Patients with Contraindications to Ordinary Percutaneous Liver Biopsy and an 'In-House' Protocol for Selecting the Procedure of Choice

    International Nuclear Information System (INIS)

    Atar, Eli; Ben Ari, Ziv; Bachar, Gil N.; Amlinski, Yelena; Neyman, Chaim; Knizhnik, Michael; Litvin, Sergey; Schmilovitz-Weiss, Hemda; Shapiro, Riki; Bruckhaimer, Elchanan; Tur-Kaspa, Ran; Belenky, Alexander

    2010-01-01

    The purpose of this study was to evaluate the effectiveness and safety of transjugular liver biopsy (TJLB) and plugged-percutaneous liver biopsy (PB) in consecutive patients with severe liver disease associated with impaired coagulation, ascites, or both and to verify the in-house protocol used to select the appropriate procedure. In 2000-2006, 329 patients (208 male [62.8%] and 121 female [37.2%]), aged 1 month to 81 years (mean, 46.8 years), underwent 150 TJLBs (39.1%) or 233 PBs (60.9%) procedures at a major tertiary center, as determined by an in-house protocol. The groups were compared for specimen characteristics, technical success, and complications. Technical success rates were 97.4% for TJLB (146/150) and 99.1% for PB (231/233). TJLB was associated with a lower average core length (1.29 vs. 1.43 cm) and lower average number of specimens obtained (2.44 vs. 2.8), but both methods yielded sufficient tissue for a definitive diagnosis. There were no major complications in either group. TJLB and PB can be safely and effectively performed for the diagnosis of hepatic disease in patients with contraindications for standard percutaneous liver biopsy. When both are technically available, we suggest PB as the procedure of choice, especially in transplanted livers.

  3. Examination of Surgical Specimens of the Esophagus.

    Science.gov (United States)

    Bejarano, Pablo A; Berho, Mariana

    2015-11-01

    Esophageal cancer continues to be one of the most lethal of all gastrointestinal malignancies. Its prognostic parameters are based on the gross and histopathologic examination of resected specimens by pathologists. To describe the implications of appropriate handling and examination of endomucosal resection and esophagectomy specimens from patients with esophageal carcinoma while considering the implications of the surgical techniques used to obtain such specimens. Parameters include histopathologic findings necessary for accurate staging, differences in the assessment of margins, residual malignancy, and criteria to evaluate for tumor regression after chemoradiation therapy as well as the role of immunohistochemistry and the judicious use of frozen sections. Sources were a review of the literature and the authors' experience handling these types of specimens. Examining surgical specimens of the esophagus is critical in the management of patients with esophageal carcinoma, and it requires careful consideration of the diagnostic pitfalls, staging-related parameters, and results of molecular tests.

  4. Discordance between location of positive cores in biopsy and location of positive surgical margin following radical prostatectomy.

    Science.gov (United States)

    Kim, Ji Won; Park, Hyoung Keun; Kim, Hyeong Gon; Ham, Dong Yeub; Paick, Sung Hyun; Lho, Yong Soo; Choi, Woo Suk

    2015-10-01

    We compared location of positive cores in biopsy and location of positive surgical margin (PSM) following radical prostatectomy. This retrospective analysis included patients who were diagnosed as prostate cancer by standard 12-core transrectal ultrasonography guided prostate biopsy, and who have PSM after radical prostatectomy. After exclusion of number of biopsy cores location data, 46 patients with PSM were identified. Locations of PSM in pathologic specimen were reported as 6 difference sites (apex, base and lateral in both sides). Discordance of biopsy result and PSM was defined when no positive cores in biopsy was identified at the location of PSM. Most common location of PSM were right apex (n=21) and left apex (n=15). Multiple PSM was reported in 21 specimens (45.7%). In 32 specimens (69.6%) with PSM, one or more concordant positive biopsy cores were identified, but 14 specimens (28%) had no concordant biopsy cores at PSM location. When discordant rate was separated by locations of PSM, right apex PSM had highest rate of discordant (38%). The discordant group had significantly lower prostate volume and lower number of positive cores in biopsy than concordant group. This study showed that one fourth of PSM occurred at location where tumor was not detected at biopsy and that apex PSM had highest rate of discordant. Careful dissection to avoid PSM should be performed in every location, including where tumor was not identified in biopsy.

  5. [Stereotactic vacuum-assisted breast biopsy (Mammotome biopsy) for non-palpable microcalcification on mammography].

    Science.gov (United States)

    Matsuzaki, Saeko; Shiba, Eiichi; Kobayashi, Yasushi; Kawai, Mieko; Kitamura, Kaeko; Nishita, Toshiyuki; Nishio, Hiroshi; Kobayashi, Nobuyuki

    2005-01-01

    The purpose of this study was to assess the benefits of stereotactic vacuum-assisted breast biopsy in patients with non-palpable microcalcification detected on mammography. Between October 2001 and November 2003, stereotactic Mammotome biopsies were performed for 150 microcalcified lesions on mammography using the prone-type stereotactic vacuum-assisted breast biopsy system (Mammotest and Mammovision, Fischer, Denver, USA) . The mammography findings were classified according to the guidelines of The Japan Radiological Society/The Japan Association of Radiological Technologists. Ninety-eight cases were category 3, 38 were category 4, and 14 were category 5. All cases were determined to be cases of microcalcification by specimen radiography or histology. Complications were negligible. One hundred twenty of the cases were mastopathy, and 30 of them were breast cancer (14 were ductal carcinoma in situ, 7 were ductal carcinoma in situ with microinvasion, and 9 were invasive ductal carcinoma). Twenty-seven breast cancers were diagnosed as category 4 or 5 (51.9%) on mammography. The operative stages of 27 cases were as follows: 7 were stage 0, 17 were stage 1, and 3 were stage 2A. Twenty-four of 27 (88.9%) were early breast cancers. Mammotome biopsy is a safe and useful modality for the histological diagnosis of non-palpable microcalcifications.

  6. Potential impact of the MR spectroscopic cancer blood test on reducing the need for lung biopsy

    International Nuclear Information System (INIS)

    Simon, M.; Fossel, E.T.

    1989-01-01

    Lung biopsies are generally performed to identify or rule out malignancy. A clinical presumption of lung malignancy without biopsy proof may result in unjustified surgery. The authors sought to test the value of the MR cancer blood test (CBT) recently described. They obtained prebiopsy blood samples (2 mL) from 65 patients undergoing lung biopsy for radiologically identified lesions. The CBT was performed blinded, and the result was then compared with the pathologic diagnosis obtained from biopsy. Results are presented

  7. Diagnosis of mediastinal neoplasms using mediastinoscopy and CT-guided needle biopsy supported by gene analysis

    International Nuclear Information System (INIS)

    Chiba, Wataru; Sawai, Satoru; Ishida, Hisao; Hanawa, Takeshi; Matsubara, Yoshito; Ikeda, Sadao; Kinoshita, Moritoshi; Ikei, Nobuhiro.

    1993-01-01

    Of 140 cases of mediastinal neoplasms in our hospital, histological diagnosis was confirmed in 129 cases. We examined the methods of preoperative biopsy with those 129 cases. Biopsy had been performed in 25 cases. Mediastinoscopy was performed in seven cases, needle biopsy in eight cases, lymph node biopsy in eight cases, esophageal biopsy using a gastrofiberscope in one case, transbronchial biopsy using a bronchoscope in one case. The true positive rates of those methods were 100% for both mediastinoscopy and lymph node biopsy, and 75% for needle biopsy. Preoperative misdiagnosis occurred in two cases of needle biopsy. The postoperative histological diagnosis was malignant lymphoma in both cases. We performed gene analysis of the immunoglobulin heavy chain gene, light chain κ and λ genes, and the T-cell receptor β gene by use of biopsied specimens, and we found rearrangement bands of these genes in the cases of malignant lymphoma. Therefore, we summarize that gene analysis is a reliable method if malignant lymphoma is suspected. If a needle biopsy is performed under CT guidance, the needle is sure to puncture the tumor. We concluded, therefore, that if a tumor is located in the anterior mediastinum, CT-guided needle biopsy should be performed first of all. Mediastinoscopy is a useful method if the tumor is located in the mid-mediastinum. (author)

  8. Comparison between hemosiderin and Technetium-99 in sentinel lymph node biopsy in human breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Vasques, Paulo Henrique Diogenes; Aquino, Ranniere Gurgel Furtado de; Pinheiro, Luiz Gonzaga Porto, E-mail: luizgporto@uol.com.br [Universidade Federal do Ceara (UFC), Fortaleza, CE (Brazil). Departamento de Cirurgia; Alves, Mayara Maia [Rede Nordeste de Biotecnologia (RENORBIO/UFC), Fortaleza, CE (Brazil); Torres, Roberto Vitor Almeida; Bezerra, Jose Lucas Martins [Universidade Federal do Ceara (UFC), Fortaleza, CE (Brazil). Faculdade de Medicina; Brasileiro, Luis Porto [Faculdades INTA, Sobral, CE (Brazil). Faculdade de Medicina

    2015-11-15

    Purpose: To assess the safety and potential equivalence of the use of hemosiderin compared to the Technetium-99 in sentinel lymph node biopsy in human breast cancer. Methods: Non-random sample of 14 volunteer women diagnosed with breast cancer with primary tumors (T1/T2) and clinically tumor-free axilla were submitted to the identification of sentinel lymph node using hemosiderin obtained from autologous blood injected in the periareolar region 24h before surgery on an outpatient basis. Patients received preoperative subareolar intradermal injection of Technetium-99 in the immediate preoperative period. Patients were submitted to sentinel lymph node biopsy, with incision in the axillary fold guided by Gamma-Probe, dissection by planes until the identification of the point of maximum uptake of Technetium-99, identifying the marked nodes and their colors. All surgical specimens were sent for pathological and immunohistochemical study. Results: The results showed no evidence of side effects and/or allergic and non-allergic reactions in patients submitted to SLNB with hemosiderin. The SLN identification rate per patient was 100%. SLNB identification rate per patient with hemosiderin was the same as that of Technetium, with a concordance rate of 100% between the methods. Conclusion: Hemosiderin is a safe dye that is equivalent to Technetium in breast sentinel lymph node biopsy. (author)

  9. Comparison between hemosiderin and Technetium-99 in sentinel lymph node biopsy in human breast cancer.

    Science.gov (United States)

    Vasques, Paulo Henrique Diógenes; Alves, Mayara Maia; Aquino, Ranniere Gurgel Furtado de; Torres, Roberto Vitor Almeida; Bezerra, José Lucas Martins; Brasileiro, Luis Porto; Pinheiro, Luiz Gonzaga Porto

    2015-11-01

    To assess the safety and potential equivalence of the use of hemosiderin compared to the Technetium-99 in sentinel lymph node biopsy in human breast cancer. Non-random sample of 14 volunteer women diagnosed with breast cancer with primary tumors (T1/T2) and clinically tumor-free axilla were submitted to the identification of sentinel lymph node using hemosiderin obtained from autologous blood injected in the periareolar region 24h before surgery on an outpatient basis. Patients received preoperative subareolar intradermal injection of Technetium-99 in the immediate preoperative period. Patients were submitted to sentinel lymph node biopsy, with incision in the axillary fold guided by Gamma-Probe, dissection by planes until the identification of the point of maximum uptake of Technetium-99, identifying the marked nodes and their colors. All surgical specimens were sent for pathological and immunohistochemical study. The results showed no evidence of side effects and/or allergic and non-allergic reactions in patients submitted to SLNB with hemosiderin. The SLN identification rate per patient was 100%. SLNB identification rate per patient with hemosiderin was the same as that of Technetium, with a concordance rate of 100% between the methods. Hemosiderin is a safe dye that is equivalent to Technetium in breast sentinel lymph node biopsy.

  10. Histological Value of Duodenal Biopsies

    Directory of Open Access Journals (Sweden)

    Limci Gupta

    2005-01-01

    Full Text Available This study was performed to see the value of histopathological diagnosis in management of patients with duodenal biopsies; to look for correlation of histology and serology in suspected cases of coeliac disease; the reasons for taking duodenal biopsies and whether proper adequate histories are provided on the forms sent with request for histopathological view on duodenal biopsies. Here are the observations of the study followed by the discussion.

  11. Image-guided pleural biopsy: diagnostic yield and complications

    Energy Technology Data Exchange (ETDEWEB)

    Benamore, R.E. [Department of Radiology and Department of Histopathology, Glenfield Hospital, University Hospitals of Leicester NHS Trust, Leicester (United Kingdom)]. E-mail: rachelbenamore@doctors.org.uk; Scott, K. [Department of Radiology and Department of Histopathology, Glenfield Hospital, University Hospitals of Leicester NHS Trust, Leicester (United Kingdom); Richards, C.J. [Department of Radiology and Department of Histopathology, Glenfield Hospital, University Hospitals of Leicester NHS Trust, Leicester (United Kingdom); Entwisle, J.J. [Department of Radiology and Department of Histopathology, Glenfield Hospital, University Hospitals of Leicester NHS Trust, Leicester (United Kingdom)

    2006-08-15

    Background: Pleural biopsy and cytology are standard procedures for the investigation of pleural disease. Recent medical literature has suggested that image-guided pleural biopsy shows improved sensitivity for the diagnosis of pleural malignancy, when compared with the more commonly performed reverse bevel needle biopsy such as Abrams' needle. In our centre there has been an increasing trend towards performing image-guided pleural biopsies, and to our knowledge there is no large published series documenting the complication rate and diagnostic yield. Methods: The radiology and pathology databases were searched for all image-guided [computed tomography (CT) and ultrasound (US)] pleural biopsies from January 2001 to December 2004. All imaging and histology were reviewed, and final diagnostic information about patients was obtained from the respiratory multidisciplinary team database and patient notes. A record was made of complications following biopsy, presence of pleura in the biopsy, and adequacy of tissue for histological diagnosis. Results: A total of 82 patients underwent 85 image-guided pleural biopsies over a 4-year period. 80 cases were performed under CT and five under US guidance. The rate of new pneumothorax detected by chest radiography was 4.7%. No patient required a chest drain or blood transfusion to treat complications. In 10 (12%) cases, there was inadequate tissue to reach a confident histological diagnosis and in eight (9%) of these, no pleura was present. Assuming all suspicious and inadequate biopsies are treated as benign, which is the worst case scenario, image-guided pleural biopsy has a sensitivity and specificity of 76% and 100%, respectively, for the diagnosis of malignant disease. Conclusions: Image-guided pleural biopsy is a safe procedure with few associated complications and has a higher sensitivity than previously published series for reverse cutting needle biopsy in the diagnosis of malignant pleural disease.

  12. Correlation of Cervical Pap Smear with Biopsy in the Lesion of Cervix.

    Science.gov (United States)

    Dhakal, R; Makaju, R; Sharma, S; Bhandari, S; Shrestha, S; Bastakoti, R

    Background Cervical cancer can be controlled to a greater extent by screening to improve morbidity and mortality. Pap smear is important screening method, which has proven to be highly effective in reducing the number of cases and the mortality from cervical carcinoma. Any abnormality detected in pap smear has to be confirmed with cervical biopsy, which remains the reference investigation. Objective To find the changes of cervical cytology by pap smear, to classify cervical lesions into malignant and benign groups on cytological and histopathological basis and to correlate the changes observed in cervical cytology with cervical biopsy. Method This is a prospective cross sectional study done in between July 2014 and July 2015 in Dhulikhel Hospital, Kathmandu University Hospital. During the period, all the samples requested for pap smear were studied. The cases who had undergone both pap smear and cervical biopsy were compared. Clinical data were obtained from requisition submitted along with the cytology and tissue specimens received in the department. Result During the study period, total 1922 pap smears were performed and out of them 75 patients were advised to do cervical biopsy. On cytology, out of total 1922 number of cases, 67.90% were normal, 27.90% were inflammatory smears, 3.80% were unsatisfactory (inadequate) and 0.40% were high grade intraepithelial lesions. Highest numbers of patients screened for pap smear ranged from 31 to 40 years. On histopathology, 78.70% had chronic cervicitis, 8% had normal findings, 1.30% had moderate and 6.70% had severe squamous intraepithelial lesions. The frank malignancy was found in 5.30%. The mean age ± SD for carcinoma was 52.75±6.29. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value of pap smear were 77.80%, 100%, 100% and 97% respectively considering cervical biopsy as the gold standard Conclusion This study revealed a good correlation of cervical cytology with cervical biopsy

  13. Biaxial Creep Specimen Fabrication

    Energy Technology Data Exchange (ETDEWEB)

    JL Bump; RF Luther

    2006-02-09

    This report documents the results of the weld development and abbreviated weld qualification efforts performed by Pacific Northwest National Laboratory (PNNL) for refractory metal and superalloy biaxial creep specimens. Biaxial creep specimens were to be assembled, electron beam welded, laser-seal welded, and pressurized at PNNL for both in-pile (JOYO reactor, O-arai, Japan) and out-of-pile creep testing. The objective of this test campaign was to evaluate the creep behavior of primary cladding and structural alloys under consideration for the Prometheus space reactor. PNNL successfully developed electron beam weld parameters for six of these materials prior to the termination of the Naval Reactors program effort to deliver a space reactor for Project Prometheus. These materials were FS-85, ASTAR-811C, T-111, Alloy 617, Haynes 230, and Nirnonic PE16. Early termination of the NR space program precluded the development of laser welding parameters for post-pressurization seal weldments.

  14. Biaxial Creep Specimen Fabrication

    International Nuclear Information System (INIS)

    JL Bump; RF Luther

    2006-01-01

    This report documents the results of the weld development and abbreviated weld qualification efforts performed by Pacific Northwest National Laboratory (PNNL) for refractory metal and superalloy biaxial creep specimens. Biaxial creep specimens were to be assembled, electron beam welded, laser-seal welded, and pressurized at PNNL for both in-pile (JOYO reactor, O-arai, Japan) and out-of-pile creep testing. The objective of this test campaign was to evaluate the creep behavior of primary cladding and structural alloys under consideration for the Prometheus space reactor. PNNL successfully developed electron beam weld parameters for six of these materials prior to the termination of the Naval Reactors program effort to deliver a space reactor for Project Prometheus. These materials were FS-85, ASTAR-811C, T-111, Alloy 617, Haynes 230, and Nirnonic PE16. Early termination of the NR space program precluded the development of laser welding parameters for post-pressurization seal weldments

  15. The usefulness of the transrectal ultrasonography in the diagnosis of the prostate cancer : comparison with systemic sextant biopsy

    International Nuclear Information System (INIS)

    Moon, Min Hoan; Seong, Chang Kyu; Jeong, Jun Yong; Choi, Huck Jae; Sim, Jung Suk; Kim, Seung Hyup

    2001-01-01

    To retrospectively compared the usefulness of the transrectal ultrasonography LEAVE A SPACE(TRUS) and systemic sextant biopsy in the diagnosis of prostate cancer. A total of 84 patients with clinical and laboratory findings suggestive of prostate cancer underwent TRUS and systemic sextant biopsy. Nine patients with diffuse prostatic lesion had been excluded from the list. Following sonographic evaluation, additional targeted biopsy for the focal lesion was performed in 14 patients. A total of 464 biopsy specimens were obtained and retrospectively compared with the sonographic findings. For cancer, the sensitivity, specificity and false-positive rate of TRUS were 48%, 97% and 53%, respectively. The hypoechoic nodules seen in prostate cancer were more commonly located in the outer half of the peripheral zone of the prostate, while most BPH lesions were located in the inner half of this zone. Between prostate cancer and BPH there was statistically significant difference in the location of hypoechoic nodules revealed by TRUS (p=0.01). The location of the hypoechoic nodules provides useful information for differentiating between BPH nodules and malignant prostatic nodules and may reduce the false-positive rate of TRUS in the diagnosis of prostate cancer

  16. Enzyme immunoassay of oestrogen receptors in needle biopsies from human liver

    DEFF Research Database (Denmark)

    Becker, U; Andersen, J; Poulsen, H S

    1991-01-01

    For quantitative assessments of sex hormone receptors in liver tissue, ligand binding assays are inconvenient, as they require large biopsies (0.5-1.0 g). The present study shows that it is possible to measure oestrogen receptors (ER) quantitatively in needle biopsy specimens as small as 10 mg...... by modifications of a commercial enzyme immunoassay employing monoclonal antibodies. Sucrose gradient centrifugation and the dextran charcoal method served as reference methods. A consecutive series of needle biopsies from patients suspected of liver disease were investigated. The biopsies (n = 37) had a median...

  17. Applying the Principles of Lean Production to Gastrointestinal Biopsy Handling: From the Factory Floor to the Anatomic Pathology Laboratory.

    Science.gov (United States)

    Sugianto, Jessica Z; Stewart, Brian; Ambruzs, Josephine M; Arista, Amanda; Park, Jason Y; Cope-Yokoyama, Sandy; Luu, Hung S

    2015-01-01

    To implement Lean principles to accommodate expanding volumes of gastrointestinal biopsies and to improve laboratory processes overall. Our continuous improvement (kaizen) project analyzed the current state for gastrointestinal biopsy handling using value-stream mapping for specimens obtained at a 487-bed tertiary care pediatric hospital in Dallas, Texas. We identified non-value-added time within the workflow process, from receipt of the specimen in the histology laboratory to the delivery of slides and paperwork to the pathologist. To eliminate non-value-added steps, we implemented the changes depicted in a revised-state value-stream map. Current-state value-stream mapping identified a total specimen processing time of 507 minutes, of which 358 minutes were non-value-added. This translated to a process cycle efficiency of 29%. Implementation of a revised-state value stream resulted in a total process time reduction to 238 minutes, of which 89 minutes were non-value-added, and an improved process cycle efficiency of 63%. Lean production principles of continuous improvement and waste elimination can be successfully implemented within the clinical laboratory.

  18. Surecut 0.6 mm liver biopsy in the diagnosis of cirrhosis

    DEFF Research Database (Denmark)

    Torp-Pedersen, S; Vyberg, Mogens; Smith, E

    1990-01-01

    material for a morphological diagnosis concerning liver architecture was obtained with both biopsy techniques (Surecut insufficient in 5 cases and Menghini insufficient in 2 cases). The biopsies were classified as cirrhosis or non-cirrhosis. There was agreement in 69 cases (97%, confidence limits 90......Liver biopsy with the 0.6 mm (23 gauge) Surecut needle was compared to conventional Menghini biopsy in the diagnosis of cirrhosis. Seventy-seven consecutive patients (mainly alcoholics) with a clinical indication for liver biopsy had both biopsies performed simultaneously. In 71 patients sufficient...

  19. The cost effectiveness of vacuum-assisted versus core-needle versus surgical biopsy of breast lesions.

    Science.gov (United States)

    Fernández-García, P; Marco-Doménech, S F; Lizán-Tudela, L; Ibáñez-Gual, M V; Navarro-Ballester, A; Casanovas-Feliu, E

    To determine the cost effectiveness of breast biopsy by 9G vacuum-assisted guided by vertical stereotaxy or ultrasonography in comparison with breast biopsy by 14G core-needle biopsy and surgical biopsy. We analyzed a total of 997 biopsies (181 vacuum-assisted, 626 core, and 190 surgical biopsies). We calculated the total costs (indirect and direct) of the three types of biopsy. We did not calculate intangible costs. We measured the percentage of correct diagnoses obtained with each technique. To identify the most cost-effective option, we calculated the mean ratios for the three types of biopsies. Total costs were €225.09 for core biopsy, €638.90 for vacuum-assisted biopsy, and €1780.01 for surgical biopsy. The overall percentage of correct diagnoses was 91.81% for core biopsy, 94.03% for vacuum-assisted biopsy, and 100% for surgical biopsy; however, these differences did not reach statistical significance (p=0.3485). For microcalcifications, the percentage of correct diagnoses was 50% for core biopsy and 96.77% for vacuum-assisted biopsy (p<0.0001). For nodules, there were no significant differences among techniques. The mean cost-effectiveness ratio considering all lesions was 2.45 for core biopsy, 6.79 for vacuum-assisted biopsy, and 17.80 for surgical biopsy. Core biopsy was the dominant option for the diagnosis of suspicious breast lesions in general. However, in cases with microcalcifications, the low percentage of correct diagnoses achieved by core biopsy (50%) advises against its use in this context, where vacuum-assisted biopsy would be the technique of choice because it is more cost-effective than surgical biopsy, the other technique indicated for biopsying microcalcifications. Copyright © 2016 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.

  20. Differences in Ki67 expressions between pre- and post-neoadjuvant chemotherapy specimens might predict early recurrence of breast cancer.

    Science.gov (United States)

    Tokuda, Emi; Horimoto, Yoshiya; Arakawa, Atsushi; Himuro, Takanori; Senuma, Koji; Nakai, Katsuya; Saito, Mitsue

    2017-05-01

    The prognosis of breast cancer patients not obtaining a pathological complete response (pCR) with neoadjuvant chemotherapy (NAC) is poorer than that of pCR patients. Identifying new prognostic factors for non-pCR patients is important because fractions of this population might benefit from novel adjuvant treatments currently under development. High Ki67 expression in remnant disease after NAC has been described as a poor prognostic factor. Studies have shown that a reduction in Ki67 expression is more often observed in good responders to chemotherapy. We hypothesized that the change in Ki67 expression might be useful for predicting patient outcomes and thus retrospectively examined pairs of biopsy and surgical specimens of breast tissue from individual patients. One hundred sixteen patients with remnant invasive disease in the breast, who received NAC and underwent surgery at our institution, were retrospectively examined. Differences in Ki67 expression between pre- and post-NAC specimens were analyzed in relation to patient outcomes. The mean Ki67 expression value after NAC was higher in patients who developed metastasis than in those without metastasis (PKi67 expression in the surgical than in the biopsy specimen were more frequent in patients with metastasis (PKi67 expressions after versus before NAC might be an important predictor of early metastasis. Evaluating not only absolute Ki67 values, but also any changes in response to NAC, may improve the prediction of patient outcomes. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Comparison of four different methods for detection of Helicobacter pylori from gastric biopsies.

    Science.gov (United States)

    Lee, N; Tsai, H N; Fang, K M

    1990-08-01

    Helicobacter pylori are commonly found colonizing the gastric mucosa of different populations. Its presence may be important in the pathogenesis of gastritis and peptic ulcer disease. The detection rates vary widely depending upon the diagnostic methods applied. In this study, multiple gastric biopsies were taken from the fundal and antral mucosa of 25 patients during endoscopy. In one patient, the procedure was repeated about two months after the initial biopsy. A total of 52 sets of specimens were obtained. One sample from each site was used to make imprint smear and tissue section. The other sample was used for microbiological culture and rapid urease test. An association between histological confirmed chronic gastritis (both active and inactive) and the morphological diagnosis of H. pylori by tissue sections was found in all of the 26 cases (52 specimens). There was an excellent concordance (96.2%) between the morphological diagnosis of H. pylori in the Gram-stained imprint smears and the tissue sections. There was a good concordance (86.5%) between the histology and the bacterial culture. Interestingly, a different species of gastric campylobacter-like organism with similar morphological appearance was also cultivated. The results of rapid urease test are unsatisfactory because urease was detected in less than 10% of culture-positive biopsies after 1 hour and 71.1% after 24 hours. In summary, culture and histology are complementary to each other. The combination of both is the "gold standard" for confirming the presence of H. pylori. As for rapid diagnosis, the Gram-stained imprint smears are shown to give satisfactory results.

  2. Positron emission mammography-guided breast biopsy.

    Science.gov (United States)

    Raylman, R R; Majewski, S; Weisenberger, A G; Popov, V; Wojcik, R; Kross, B; Schreiman, J S; Bishop, H A

    2001-06-01

    Positron emission mammography (PEM) is a technique to obtain planar images of the breast for detection of potentially cancerous, radiotracer-avid tumors. To increase the diagnostic accuracy of this method, use of minimally invasive methods (e.g., core biopsy) may be desirable for obtaining tissue samples from lesions detected with PEM. The purpose of this study was to test the capabilities of a novel method for performing PEM-guided stereotactic breast biopsies. The PEM system consisted of 2 square (10 x 10 cm) arrays of discrete scintillator crystals. The detectors were mounted on a stereotactic biopsy table. The stereotactic technique used 2 PEM images acquired at +/-15 degrees and a new trigonometric algorithm. The accuracy and precision of the guidance method was tested by placement of small point sources of (18)F at known locations within the field of view of the imager. The calculated positions of the sources were compared with the known locations. In addition, simulated stereotactic biopsies of a breast phantom consisting of a 10-mm-diameter gelatin sphere containing a concentration of (18)F-FDG consistent with that reported for breast cancer were performed. The simulated lesion was embedded in a 4-cm-thick slab of gelatin containing a commonly reported concentration of FDG, simulating a compressed breast (target-to-background ratio, approximately 8.5:1). An anthropomorphic torso phantom was used to simulate tracer uptake in the organs of a patient 1 h after a 370-MBq injection of FDG. Five trials of the biopsy procedure were performed to assess repeatability. Finally, a method for verifying needle positioning was tested. The positions of the point sources were successfully calculated to within 0.6 mm of their true positions with a mean error of +/-0.4 mm. The biopsy procedures, including the method for verification of needle position, were successful in all 5 trials in acquiring samples from the simulated lesions. The success of this new technique shows its

  3. NASA Biological Specimen Repository

    Science.gov (United States)

    McMonigal, K. A.; Pietrzyk, R. A.; Sams, C. F.; Johnson, M. A.

    2010-01-01

    The NASA Biological Specimen Repository (NBSR) was established in 2006 to collect, process, preserve and distribute spaceflight-related biological specimens from long duration ISS astronauts. This repository provides unique opportunities to study longitudinal changes in human physiology spanning may missions. The NBSR collects blood and urine samples from all participating ISS crewmembers who have provided informed consent. These biological samples are collected once before flight, during flight scheduled on flight days 15, 30, 60, 120 and within 2 weeks of landing. Postflight sessions are conducted 3 and 30 days after landing. The number of in-flight sessions is dependent on the duration of the mission. Specimens are maintained under optimal storage conditions in a manner that will maximize their integrity and viability for future research The repository operates under the authority of the NASA/JSC Committee for the Protection of Human Subjects to support scientific discovery that contributes to our fundamental knowledge in the area of human physiological changes and adaptation to a microgravity environment. The NBSR will institute guidelines for the solicitation, review and sample distribution process through establishment of the NBSR Advisory Board. The Advisory Board will be composed of representatives of all participating space agencies to evaluate each request from investigators for use of the samples. This process will be consistent with ethical principles, protection of crewmember confidentiality, prevailing laws and regulations, intellectual property policies, and consent form language. Operations supporting the NBSR are scheduled to continue until the end of U.S. presence on the ISS. Sample distribution is proposed to begin with selections on investigations beginning in 2017. The availability of the NBSR will contribute to the body of knowledge about the diverse factors of spaceflight on human physiology.

  4. Risk factors for acute prostatitis after transrectal biopsy of the prostate.

    Science.gov (United States)

    Kim, Sang Jin; Kim, Sun Il; Ahn, Hyun Soo; Choi, Jong Bo; Kim, Young Soo; Kim, Se Joong

    2010-06-01

    To investigate the incidence, clinical features, pathogenic bacteria, and risk factors associated with acute prostatitis after transrectal prostate biopsy. We retrospectively reviewed the medical records of 923 transrectal ultrasound-guided needle biopsies of the prostate in 878 patients performed at our institution from June 2004 to May 2009. The indications for biopsy were generally serum prostate-specific antigen (PSA) elevation, abnormal findings on a digital rectal examination, or both. All biopsies were performed with the patient hospitalized except for 10 patients who refused to be hospitalized, and ciprofloxacin was administered as an antibiotic prophylaxis. The incidence, clinical features, pathogenic bacteria, and potential risk factors associated with acute prostatitis after prostate biopsy were evaluated. Acute prostatitis developed in 18 (2.0%) cases after prostate biopsy. Among them, 9 (1.0%) had bacteremia and 2 (0.2%) showed clinical features of sepsis. Of the total 50 urine or blood specimens sent for culture study, 27 (54.0%) specimens showed positive cultures, including E. coli in 25. Among the 27 culture-positive specimens, 26 (96.3%) were resistant to ciprofloxacin. Among the potential risk factors for acute prostatitis after prostate biopsy, biopsy performed as an outpatient procedure without a cleansing enema (p=0.001) and past history of cerebrovascular accident (p=0.048) were statistically significant. Fluoroquinolone is effective as an antibiotic prophylaxis for transrectal prostate biopsy in most cases. The incidence of acute prostatitis after transrectal prostate biopsy was 2.0%, and almost all cases were caused by fluoroquinolone-resistant E. coli. A cleansing enema is recommended before transrectal prostate biopsy.

  5. Utility of bronchial lavage fluids for epithelial growth factor receptor mutation assay in lung cancer patients: Comparison between cell pellets, cell blocks and matching tissue specimens.

    Science.gov (United States)

    Asaka, Shiho; Yoshizawa, Akihiko; Nakata, Rie; Negishi, Tatsuya; Yamamoto, Hiroshi; Shiina, Takayuki; Shigeto, Shohei; Matsuda, Kazuyuki; Kobayashi, Yukihiro; Honda, Takayuki

    2018-02-01

    The detection of epidermal growth factor receptor ( EGFR ) mutations is necessary for the selection of suitable patients with non-small cell lung cancer (NSCLC) for treatment with EGFR tyrosine kinase inhibitors. Cytology specimens are known to be suitable for EGFR mutation detection, although tissue specimens should be prioritized; however, there are limited studies that examine the utility of bronchial lavage fluid (BLF) in mutation detection. The purpose of the present study was to investigate the utility of BLF specimens for the detection of EGFR mutations using a conventional quantitative EGFR polymerase chain reaction (PCR) assay. Initially, quantification cycle (Cq) values of cell pellets, cell-free supernatants and cell blocks obtained from three series of 1% EGFR mutation-positive lung cancer cell line samples were compared for mutation detection. In addition, PCR analysis of BLF specimens obtained from 77 consecutive NSCLC patients, detecting EGFR mutations was validated, and these results were compared with those for the corresponding formalin-fixed paraffin-embedded (FFPE) tissue specimens obtained by surgical resection or biopsy of 49 of these patients. The Cq values for mutation detection were significantly lower in the cell pellet group (average, 29.58) compared with the other groups, followed by those in cell-free supernatants (average, 34.15) and in cell blocks (average, 37.12) for all three series (Pmatching FFPE tissue specimens. Notably, EGFR mutations were even detected in 10 cytological specimens that contained insufficient tumor cells. EGFR mutation testing with BLF specimens is therefore a useful and reliable method, particularly when sufficient cancer cells are not obtained.

  6. Comparative study on Charpy specimen reconstitution techniques

    International Nuclear Information System (INIS)

    Bourdiliau, B.; Decroix, G.-M.; Averty, X.; Wident, P.; Bienvenu, Y.

    2011-01-01

    Highlights: → Welding processes are used to reconstitute previously tested Charpy specimens. → Stud welding is preferred for a quick installation, almost immediately operational. → Friction welding produces better quality welds, but requires a development effort. - Abstract: Reconstitution techniques are often used to allow material from previously fractured Charpy-V specimens to be reused for additional experiments. This paper presents a comparative experimental study of various reconstitution techniques and evaluates the feasibility of these methods for future use in shielded cells. The following techniques were investigated: arc stud welding, 6.0 kW CO 2 continuous wave laser welding, 4.5 kW YAG continuous wave laser welding and friction welding. Subsize Charpy specimens were reconstituted using a 400 W YAG pulsed wave laser. The best result was obtained with arc stud welding; the resilience of the reconstituted specimens and the load-displacement curves agreed well with the reference specimens, and the temperature elevation caused by the welding process was limited to the vicinity of the weld. Good results were also obtained with friction welding; this process led to the best quality welds. Laser welding seems to have affected the central part of the specimens, thus leading to different resilience values and load-displacement curves.

  7. Development of a permanently controllable rotating biopsy device. Pt. I. Theoretical considerations and in-vitro results for five different prototypes

    International Nuclear Information System (INIS)

    Schaefer, Philipp Jost; Jahnke, T.; Andres, H.; Heller, M.; Schaefer, F.K.; Hedderich, J.

    2009-01-01

    Purpose: to develop different prototypes of permanently controllable rotating biopsy devices with determination of the most efficient prototype in biopsies in bovine myocardium. Materials and Methods: Five different prototypes of 18-gauge rotating biopsy devices were designed and constructed, four (1-4) with various drill-like cutting edges and one (5) cannula type with a lancet-like helically bent cutting edge. Using bovine myocardium as the biopsy tissue, n = 100 specimens per prototype were obtained, and a quantitative analysis including tissue fragmentation, length in mm and weight in mg was carried out. For statistical analysis, the chi-square test for tissue fragmentation and Kruskal-Wallis test for the parameters length and weight were calculated. Results: prototype 5 showed the highest rate of extraction of one-fragment specimens in n=66 cases and the lowest rate of failure to obtain tissue in n=11 cases. The mean length/weight were 4.15 mm/3.91 mg for prototype 1, 1.80 mm/1.66 mg for prototype 2, 4.61 mm/3.28 mg for prototype 3, 5.20 mm/3.74 mg for prototype 4, and 9.57 mm/6.97 mg for prototype 5. In all three categories, prototype 5 was significantly superior to the prototypes 1-4 with p < 0.001. Conclusion: the cannula type with a lancet-like helically bent cutting edge proved to be the most efficient prototype and may now be tested competitively against established automated biopsy devices in vitro. (orig.)

  8. How to improve microscopic images obtained with consumer-type digital cameras.

    Science.gov (United States)

    Regitnig, P; van Paasen, R; Tsybrovskyy, O

    2003-05-01

    Digital imaging is useful in conventional photography because it immediately provides images, and the image quality can be improved afterwards by the use of computer programs. The major disadvantages of consumer-type digital cameras mounted on microscopes are (i) unequal illumination through the image, and (ii) a coloured background. A computer program was specifically adapted and refined to improve images obtained with consumer-type digital cameras mounted on microscopes. An approach using a division operation between the specimen image and a background image leads to homogeneous illumination throughout the image, with automatically corrected brightness and white background. The correct colour spectrum is preserved by correction of the histogram. This approach was obtained from the freeware computer program 'Image Arithmetic'. In a test, three different consumer-type digital cameras (Sony, Nikon, Olympus) on different microscopes were used to obtain images of different types of histological specimens (cervical smear, bone marrow biopsy, and colonic biopsy). The computer program dramatically improved the quality of images obtained with all tested cameras. Using this approach, even low-cost digital cameras mounted on microscopes produce brilliant images with homogeneous illumination and a white background, the image quality being comparable with expensive cameras especially designed for microscopes.

  9. Kidney biopsy in west of Iran: Complications and histopathological findings

    Science.gov (United States)

    Rahbar, M.

    2009-01-01

    In this retrospective study, we reviewed the medical records and histopathology findings of 135 patients who underwent renal biopsies at two special hospitals affiliated to Kermanshah medical university during a six-year period (2003-2007). All were performed using Tru-Cut needle under ultrasound guidance. Twenty four specimens were unsatisfactory. There were 38 males (34.2%) and 73 females (65.7%) in 111 patients with adequate specimens (each specimen has more than 5 glomeruli); the mean age was 16.5 years (range 2-64 years). Side effects of the renal biopsies included pain at the site of biopsy in 2 (2.7%), gross hematuria in 1 (0.9%). Nephrotic syndrome was the most common indication for biopsy followed by acute renal failure of unknown etiology and nephritic syndrome. Primary glomerular disease was reported in 78 patients (70.2%) and also secondary glomerular disease in 33 patients (29.7%). Among the primary glomerulonephritis disease, minimal change disease and membranous glomerulonephritis were the commonest findings in children below the age of 16 years. Minimal change disease ranked first in adults whole membranous glomerular disease and focal segmental glomerulosclerosis were more common in the elderly. In all patients lupus glomerular disease was the commonest secondary glomerular disease. We conclude that study on renal biopsy makes final diagnosis which is associated with an acceptably low rate of complications in our practice, and in all, the patterns of renal histology in our study vary slightly from those reported from other countries. PMID:20368927

  10. [Sample representativeness and incidence of liver biopsy complications caused by needles of bigger diameter (1.6 mm) and smaller diameter (1.2 mm) in children with cholestatic syndrome].

    Science.gov (United States)

    Bosković, Aleksandra; Kitić, Ivana; Prokić, Dragan; Stanković, Ivica

    2013-01-01

    Percutaneous liver biopsy and histomorphological analysis of liver tissue is an important diagnostic procedure in the investigation of neonates and infants with cholestatic syndrome. This study has been aimed at determining whether there is a difference in the incidence of complications after liver biopsy performed by Menghini technique using a needle of 1.6 mm as compared to 1.2 mm diameter and if there is a difference in the sample representativeness of liver tissue after liver biopsy with those two different needle diameters. We retrospectively reviewed medical records of 156 neonates and infants with chronic cholestatic syndrome, hospitalized at Mother and Child Health Care Institute, Serbia. One hundred and fifty six children underwent liver biopsy. There was no difference in frequency of liver biopsy complications performed by Menghini technique using a larger diameter needle (1.6 mm) as compared to 1.2 mm diameter. The mortality after liver biopsy was 0% while the frequency of complications with a needle of 1.6 mm in diameter was 3.8% the percentage of serious complications being 0.6%. Among the samples of liver biopsy taken by a larger diameter needle (1.6 mm), 108/109 were representative samples (> 5 portal areas), and among those taken by a smaller diameter needle (1.2 mm), 34/47 were representative samples. Of 109 liver biopsy specimens obtained by Menghini technique using a needle of larger diameter (1.6 mm), 109/109 were representative samples (> 3 portal areas), and when a smaller diameter needle (1.2 mm) was used, 42/47 were representative samples. Our results indicate that the sample representativeness was significantly higher when a larger diameter needle was used for liver biopsy by Menghini technique; however, no difference in the incidence of complications was observed.

  11. Fine-needle aspiration biopsy of intraosseous jaw lesions.

    Science.gov (United States)

    August, M; Faquin, W C; Ferraro, N F; Kaban, L B

    1999-11-01

    This study assessed diagnostic accuracy, determined reasons for error, and evaluated modifications to improve the reliability of fine-needle aspiration biopsy (FNAB) of primary jaw lesions. This was a retrospective review of 32 FNABs of intraosseous jaw lesions performed at the Massachusetts General and Children's Hospital between 1993 and 1998. A consistent, standardized technique was used, and each case was evaluated for 1) adequacy of cells to allow diagnosis, 2) presence of malignant cells, and 3) correlation between FNAB diagnosis and the final histopathology. Material obtained by FNAB was adequate for evaluation in 30 of 32 cases. No complications were reported. Malignant cells were found in 5 of 30 cases. FNAB diagnosis was confirmed by histopathology in all 5 of these specimens (100% accuracy). The FNAB diagnosis of benign lesions was confirmed in 17 of 25 cases (68%). The most common benign lesions were odontogenic cysts, ameloblastomas, and fibro-osseous and giant cell lesions. Incorrect diagnosis was related to lack of architectural context of the FNAB material, sampling of a nonrepresentative part of a large lesion, and inadequate quantity or quality of the aspirate. FNAB is a useful technique to distinguish between malignant and benign intraosseous jaw lesions. Its simplicity, suitability as an outpatient procedure, rapidity of interpretation, and minimal morbidity potentially make it the diagnostic tool of choice in the hospital setting.

  12. Imaging regional variation of cellular proliferation in gliomas using 3'-deoxy-3'-[18F]fluorothymidine positron-emission tomography: an image-guided biopsy study

    International Nuclear Information System (INIS)

    Price, S.J.; Fryer, T.D.; Cleij, M.C.; Dean, A.F.; Joseph, J.; Salvador, R.; Wang, D.D.; Hutchinson, P.J.; Clark, J.C.; Burnet, N.G.; Pickard, J.D.; Aigbirhio, F.I.

    2009-01-01

    Aim: To compare regional variations in uptake of 3'-deoxy-3'- [ 18 F]-fluorothymidine (FLT) images using positron-emission tomography (PET) with measures of cellular proliferation from biopsy specimens obtained by image-guided brain biopsies. Materials and methods: Fourteen patients with a supratentorial glioma that required an image-guided brain biopsy were imaged preoperatively with dynamic PET after the administration of FLT. Maps of FLT irreversible uptake rate (K i ) and standardized uptake value (SUV) were calculated. These maps were co-registered to a gadolinium-enhanced T1-weighted spoiled gradient echo (SPGR) sequence that was used for biopsy guidance, and the mean and maximum K i and SUV determined for each biopsy site. These values were correlated with the MIB-1 labelling index (a tissue marker of proliferation) from these biopsy sites. Results: A total of 57 biopsy sites were studied. Although all measures correlated with MIB-1 labelling index, K i max provided the best correlation (Pearson coefficient, r = 0.68; p i mean (±SD) was significantly higher than in normal tissue (3.3 ± 1.7 x 10 -3 ml plasma /min/ml tissue versus 1.2 ± 0.7 x 10 -3 ml plasma /min/ml tissue ; p = 0.001). High-grade gliomas showed heterogeneous uptake with a mean K i of 7.7 ± 4 x 10 -3 ml plasma /min/ml tissue . A threshold K i mean of 1.8 x 10 -3 differentiates between normal tissue and tumour (sensitivity 84%, specificity 88%); however, the latter threshold underestimated the extent of tumour in half the cases. SUV closely agreed with K i measurements. Conclusion: FLT PET is a useful marker of cellular proliferation that correlates with regional variation in cellular proliferation; however, it is unable to identify the margin of gliomas

  13. Association between Helicobacter pylori concentration and the combining frequency of histopathological findings in gastric biopsies specimens Associação entre a concentração de Helicobacter pylori e a freqüência de combinação de alterações histopatológicas em biopsias gástricas

    Directory of Open Access Journals (Sweden)

    Gisele Alborghetti Nai

    2007-09-01

    Full Text Available BACKGROUND: Helicobacter pylori is the most prevalent infectious agent worldwide. About 90% of patients with chronic gastritis are infected with this bacterium. Some studies have shown a association between the H. pylori concentration and the scores of gastritis activity and severity. AIM: To evaluate the association between H. pylori concentration and the combining frequency of findings on histopathological examination. METHODS: Two hundred consecutive gastric endoscopic biopsies diagnosed as chronic gastritis were retrospectively investigated. The Warthin-Starry silver stain was used to study H. pylori and the following parameters were assessed (according to the Sydney system: 1. infiltration by polymorphonuclear cells in chorio and epithelium (activity graded as mild, moderate and marked; 2. presence of lymphoid follicles; 3. presence of intestinal metaplasia; 4. presence of regenerative cell atypias, graded as mild, moderate and marked; and 5. H. pylori concentration on the mucous covering the foveolar epithelium. RESULTS: The most frequent association was chronic gastritis and activity, regardless of H. pylori concentration. The association of five histopathological findings in the same biopsy has not occurred in the cases of higher concentration of H. pylori. CONCLUSION: Our study has not revealed any association between H. pylori concentration and an increasing in the number of histopathological findings found in the gastric mucosa. Since referring to its presence is much more important than to its concentration.RACIONAL: O Helicobacter pylori é o agente infeccioso com maior prevalência em todo o mundo. Cerca de 90% dos pacientes com gastrite crônica têm infecção por esta bactéria. Alguns estudos demonstram correlação entre a concentração de H. pylori e o grau de severidade e atividade da gastrite. OBJETIVOS: Avaliar a associação entre a concentração de H. pylori e a freqüência de combinações de alterações no exame

  14. Prevalence of Prognostic Biomarkers in Archival Specimens and Breast Cancer Survival Among White, Black, and Asian Women

    National Research Council Canada - National Science Library

    Krieger, Nancy

    1998-01-01

    We assessed distributions of breast cancer tumor characteristics and molecular prognostic biomarkers by race/ethnicity and socioeconomic position among paraffin-embedded tumor biopsy specimens from 135 U.S. women...

  15. [Usefulness of Helicobacter pylori detection from feces specimens of the patients with peptic ulcer by polymerase chain reaction].

    Science.gov (United States)

    Kurokawa, M; Minamide, M; Nukina, M; Nakanishi, H; Miki, K; Tomita, S; Tohdo, A; Haruta, T

    1997-11-01

    Detection of Helicobacter pylori was studied on the feces and biopsy specimens of 91 patients with gastric ulcer by using cultured and polymerase chain reaction methods. Number of samples from feces and biopsy specimens were 1 (1.1%) and 56 (61.5%) by culture method, on the other hands 49 (53.8%) and 70 (76.9%) in polymerase chain reaction method, respectively. Sensitivity of polymerase chain reaction applied to feces and biopsy specimens were 68.1 and 97.2, respectively. Noninvasive diagnosis such as detection of organisms from feces is effective for patients who have difficulty in collecting the gastric biopsy specimens. Infection route was not clarified, however, fecal-to-oral transmission was strongly suggested by the fact that the organisms were detected from feces samples in this study.

  16. Improving bone marrow biopsy quality through peer discussion and data comparisons: A single institution experience.

    Science.gov (United States)

    Yang, R K; Nazeef, M; Patel, S S; Mattison, R; Yang, D T; Ranheim, E A; Leith, C P

    2018-03-25

    Bone marrow biopsy (BMB) is crucial for the diagnosis, staging, and monitoring of a variety of hematologic diseases. Obtaining an adequate BMB can be challenging given the need to balance patient comfort with acquisition of high quality specimens. We had observed variable BMB quality at our institution with poor quality specimens sometimes affecting diagnosis. We thus undertook this quality improvement (QI) project to improve the quality of diagnostic BMB specimens. We used an A3 QI process to identify factors possibly influencing BMB quality. We collected baseline data on 211 BMB, with short and long-term follow-up data on a further 382 cases. We used clinical conferences to discuss data, perform peer comparisons and identify strategies to create a sustainable improvement in BMB quality. Baseline data showed that BMB length was influenced most by the individual performer, with some influence of needle gauge. Other factors such as sedation, BMB indication were noncontributory. BMB lengths improved following performer education and individual performer data comparisons (15.2 mm post vs 12.8 mm baseline, P quality, leading to easier pathology diagnosis. © 2018 John Wiley & Sons Ltd.

  17. An experience with the Advanced Breast Biopsy Instrumentation (ABBI) system in the management of non-palpable breast lesions

    Energy Technology Data Exchange (ETDEWEB)

    Insausti, Pina L.; Vivas, I.; Martinez-Cuesta, A.; Bergaz, F. [Department of Radiology, Clinica Universitaria de Navarra, Pamplona (Spain); Alberro, J.A. [Department of General Surgery, Instituto Oncologico, San Sebastian (Spain); Regueira, F.M.; Zornoza, G. [Department of General Surgery, Clinica Universitaria de Navarra, C/Pio XII, 36, 31008 Pamplona (Spain); Imana, J. [Department of Radiology, Instituto Oncologico, San Sebastian (Spain); Errasti, T. [Department of Gynaecology, Clinica Universitaria de Navarra, C/Pio XII, 36, 31008 Pamplona (Spain); Rezola, R. [Department of Pathology, Instituto Oncologico, 20012 San Sebastian (Spain)

    2002-07-01

    Our objective was to evaluate our experience with the Advanced Breast Biopsy Instrumentation system (ABBI) in non-palpable breast lesions in a prospective study from July 1998 to November 2000. The ABBI system was included in a protocol for BIRADS 4 non-palpable, small (<15 mm) breast lesions. Digital radiographs of both specimen and biopsy cavity were obtained to validate the procedure. A total of 255 ABBI biopsies were performed in 254 patients. In 251 cases the lesions were successfully removed (98.4%). Mammographic lesions consisted of 176 cases of microcalcifications (69%), 51 cases of architectural distortions (20%) and 28 cases of nodules (11%). Seventy-two carcinomas were diagnosed (28.2%). Affected margins were found in 41 cases (56.9%). Residual tumour was seen in 31 patients (43%). Seventeen borderline results and 33 benign architectural distortions obviated further procedures. The complication rate in 10 cases was as follows: 3 wound infections; 4 haematomas; and 3 vasovagal reactions. The main utility of the ABBI system is to allow a reliable diagnosis in complex lesions, such as small clusters of microcalcifications and especially architectural distortions. Surgery can be avoided for borderline cases if the lesion is completely removed and free margins are obtained in the pathology study. Therapeutic use is controversial and can be applied only in selected cases. (orig.)

  18. Comparative study between biopsy and brushing sampling methods for detection of human papillomavirus in oral and oropharyngeal cavity lesions.

    Science.gov (United States)

    Marques, Marise da Penha Costa; Bussoloti Filho, Ivo; Rossi, Lia Mara; Andreoli, Maria Antonieta; Cruz, Natália Oliveira

    2015-01-01

    Many epidemiological studies have suggested that human papillomavirus (HPV), especially type 16, is involved in the genesis of squamous cell carcinoma of the oral cavity and oropharynx, especially in young, non-smoking patients; thus, its detection in lesions in this region is important. To clarify the capacity of the brushing sampling method to detect the presence of HPV in oral or oropharyngeal lesions through polymerase chain reaction (PCR) testing, and to compare the results with those obtained by biopsy. Prospective study of adult patients with oral or oropharyngeal lesions assessed by PCR, comparing biopsy specimens with samples obtained by the brushing method. The study was approved by the Research Ethics Committee of the institution. A total of 35 sample pairs were analyzed, but 45.7% of the brushing samples were inadequate (16/35) and, thus, only 19 pairs could be compared. There was agreement of results in 94.7% (18/19) of the pairs, with HPV identified in 16 of them. HPV DNA was detected in 8.6% (3/35) of biopsy and 5.7% (2/35) of brushing samples. There was no statistically significant difference between the two methods, but the brushing sampling method showed a higher number of inadequate samples, suggesting that it is an unreliable method for surveillance. Copyright © 2015 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  19. Intraductal Carcinoma of the Prostate on Diagnostic Needle Biopsy Predicts Prostate Cancer Mortality: A Population-Based Study.

    Science.gov (United States)

    Saeter, Thorstein; Vlatkovic, Ljiljana; Waaler, Gudmund; Servoll, Einar; Nesland, Jahn M; Axcrona, Karol; Axcrona, Ulrika

    2017-06-01

    Intraductal carcinoma of the prostate (IDC-P) is a distinct histopathologic feature associated with high-grade, advanced prostate cancer. Although studies have shown that IDC-P is a predictor of progression following surgical or radiation treatment for prostate cancer, there are sparse data regarding IDC-P on diagnostic needle biopsy as a prognosticator of prostate cancer mortality. This was a population-based study of all prostate cancer patients diagnosed using needle biopsy and without evidence of systemic disease between 1991 and 1999 within a defined geographic region of Norway. Patients were identified by cross-referencing the Norwegian Cancer Registry. Of 318 eligible patients, 283 had biopsy specimens available for central pathology review. Clinical data were obtained from medical charts. We examined whether IDC-P on diagnostic needle biopsy was associated with adverse clinicopathological features and prostate cancer mortality. Patients with IDC-P on diagnostic needle biopsy had a more advanced stage and a higher Gleason score compared to patients without IDC-P. IDC-P was also associated with an intensively reactive stroma. The 10-year prostate cancer-specific survival was 69% for patients with IDC-P on diagnostic needle biopsy and 89% for patients without IDC-P (Log rank P-value prostate cancer mortality after adjustments for clinical prognostic factors and treatment. After adjustment for the newly implemented Grade Group system of prostate cancer, IDC-P showed a strong tendency toward statistical significance. However, IDC-P did not remain a statistically significant predictor in the multivariable analysis. IDC-P on diagnostic needle biopsy is an indicator of prostate cancer with a high risk of mortality. Accordingly, a diagnosis of IDC-P on needle biopsy should be reported and considered a feature of high-risk prostate cancer. Moreover, the association between IDC-P and reactive stroma provides evidence in support of the idea that stromal factors

  20. Friction Compensation in the Upsetting of Cylindrical Test Specimens

    DEFF Research Database (Denmark)

    Christiansen, Peter; Martins, P. A. F.; Bay, Niels Oluf

    2016-01-01

    This manuscript presents a combined numerical andexperimental methodology for determining the stress-straincurve of metallic materials from the measurements of forceand displacement obtained in the axial compression of cylindrical test specimens with friction between the specimens and the platens...... model or combined friction models are utilized .Experimental results obtained from cylindrical and Rastegaev test specimens with different lubricants combined with the experimental determination of friction by means of ring compression tests allows compensating the effect of friction...

  1. Thermal property testing technique on micro specimen

    International Nuclear Information System (INIS)

    Baba, Tetsuya; Kishimoto, Isao; Taketoshi, Naoyuki

    2000-01-01

    This study aims at establishment of further development on some testing techniques on the nuclear advanced basic research accumulated by the National Research Laboratory of Metrology for ten years. For this purpose, a technology to test heat diffusion ratio and specific heat capacity of less than 3 mm in diameter and 1 mm in thickness of micro specimen and technology to test heat diffusion ratio at micro area of less than 1 mm in area along cross section of less than 10 mm in diameter of column specimen were developed to contribute to common basic technology supporting the nuclear power field. As a result, as an element technology to test heat diffusion ratio and specific heat capacity of the micro specimen, a specimen holding technique stably to hold a micro specimen with 3 mm in diameter could be developed. And, for testing the specific heat capacity by using the laser flush differential calorimetry, a technique to hold two specimen of 5 mm in diameter at their proximities was also developed. In addition, by promoting development of thermal property data base capable of storing thermal property data obtained in this study and with excellent workability in this 1998 fiscal year a data in/out-put program with graphical user interface could be prepared. (G.K.)

  2. Usefulness of GATA-3 as a marker of seminal epithelium in prostate biopsies.

    Science.gov (United States)

    Ortiz-Rey, J A; Chantada-de la Fuente, D; Peteiro-Cancelo, M Á; Gómez-de María, C; San Miguel-Fraile, M P

    2017-11-01

    The incidental presence of seminal vesicle epithelium in prostate needle biopsies is generally recognisable through routine microscopy. However, the biopsy can sometimes be erroneously interpreted as malignant due to its architectural and cytological characteristics, and immunohistochemistry can be useful for correctly identifying the biopsy. Our objective was to analyse the potential usefulness of GATA-3 as a marker of seminal epithelium. Through immunohistochemistry with a monoclonal anti-GATA-3 antibody (clone L50-823), we studied seminal vesicle sections from 20 prostatectomy specimens, 12 prostate needle biopsies that contained seminal vesicle tissue and 68 prostate biopsies without seminal vesicle epithelium, 36 of which showed adenocarcinoma. Staining for GATA-3 was intense in the 20 seminal vesicles of the prostatectomy specimens and in the 12 prostate needle biopsies that contained seminal epithelium. In the 60 biopsies without a seminal vesicle, GATA-3 was positive in the prostate basal cells and even in the secretory cells (57 cases), although with less intensity in 55 of the cases. One of the 36 prostatic adenocarcinomas tested positive for GATA-3. The intense immunohistochemical expression of GATA-3 in the seminal vesicle epithelium can help identify the epithelium in prostate biopsies. This marker is also positive in the basal cells of healthy prostates and, with less intensity, in the secretory cells. Positivity, weak or moderate, is observed on rare occasions in prostatic adenocarcinomas. Copyright © 2017 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  3. Ultrasonic Needles for Bone Biopsy.

    Science.gov (United States)

    Mathieson, Andrew; Wallace, Robert; Cleary, Rebecca; Li Li; Simpson, Hamish; Lucas, Margaret

    2017-02-01

    Bone biopsy is an invasive clinical procedure, where a bone sample is recovered for analysis during the diagnosis of a medical condition. When the architecture of the bone tissue is required to be preserved, a core-needle biopsy is taken. Although this procedure is performed while the patient is under local anaesthesia, the patient can still experience significant discomfort. Additionally, large haematoma can be induced in the soft tissue surrounding the biopsy site due to the large axial and rotational forces, which are applied through the needle to penetrate bone. It is well documented that power ultrasonic surgical devices offer the advantages of low cutting force, high accuracy, and preservation of soft tissues. This paper reports a study of the design, analysis, and test of two novel power ultrasonic needles for bone biopsy that operate using different configurations to penetrate bone. The first utilizes micrometric vibrations generated at the distil tip of a full-wavelength resonant ultrasonic device, while the second utilizes an ultrasonic-sonic approach, where vibrational energy generated by a resonant ultrasonic horn is transferred to a needle via the chaotic motion of a free-mass. It is shown that the dynamic behavior of the devices identified through experimental techniques closely match the behavior calculated through numerical and finite-element analysis methods, demonstrating that they are effective design tools for these devices. Both devices were able to recover trabecular bone from the metaphysis of an ovine femur, and the biopsy samples were found to be comparable to a sample extracted using a conventional biopsy needle. Furthermore, the resonant needle device was also able to extract a cortical bone sample from the central diaphysis, which is the strongest part of the bone, and the biopsy was found to be superior to the sample recovered by a conventional bone biopsy needle.

  4. Clinical utility of endorectal MRI-guided prostate biopsy: Preliminary experience

    Science.gov (United States)

    Jung, Adam J.; Westphalen, Antonio C.; Kurhanewicz, John; Wang, Zhen J.; Carroll, Peter R.; Simko, Jeffry P.; Coakley, Fergus V.

    2013-01-01

    Purpose To investigate the potential clinical utility of endorectal MRI-guided biopsy in patients with known or suspected prostate cancer. Methods We prospectively recruited 24 men with known or suspected prostate cancer in whom MRI-guided biopsy was clinically requested after multiparametric endorectal MRI showed one or more appropriate targets. One to six 18-gauge biopsy cores were obtained from each patient. Transrectal ultrasound guided biopsy results and post MRI-guided biopsy complications were also recorded. Results MRI-guided biopsy was positive in 5 of 7 patients with suspected prostate cancer (including 2 of 4 with prior negative ultrasound-guided biopsies), in 8 of 12 with known untreated prostate cancer (including 5 where MRI-guided biopsy demonstrated a higher Gleason score than ultrasound guided biopsy results), and in 3 of 5 with treated cancer. MRI-guided biopsies had a significantly higher maximum percentage of cancer in positive cores when compared to ultrasound guided biopsy (mean of 37 ± 8% versus 13 ± 4%; p = 0.01). No serious post-biopsy complications occurred. Conclusion Our preliminary experience suggests endorectal MRI-guided biopsy may safely contribute to the management of patients with known or suspected prostate cancer by making a new diagnosis of malignancy, upgrading previously diagnosed disease, or diagnosing local recurrence. PMID:24924999

  5. Diagnostic accuracy and complication rate of CT-guided fine needle aspiration biopsy of lung lesions: A study based on the experience of the cytopathologist

    Energy Technology Data Exchange (ETDEWEB)

    Massimiliano Priola, Adriano; Priola, Sandro Massimo; Cataldi, Aldo; Paze, Francesco (Dept. of Diagnostic and Interventional Radiology, Univ. of Turin, S. Luigi Gonzaga Hospital, Turin (Italy)), e-mail: adriano.priola@inwind.it; Di Franco, Marisa (Dept. of Pharmacology, S. Luigi Gonzaga Hospital, Orbassano, Turin (Italy)); Marci, Valerio (Dept. of Pathology, S. Luigi Gonzaga Hospital, Orbassano, Turin (Italy)); Berruti, Alfredo (Dept. of Oncology, S. Luigi Gonzaga Hospital, Orbassano, Turin (Italy))

    2010-06-15

    Background: CT-guided transthoracic needle biopsy is a well-established technique for the diagnosis of focal lung lesions. Fine needle aspiration biopsy (FNAB) requires the presence of a cytopathologist on-site to assess the adequacy of samples. For this reason FNAB is less and less used, and core biopsy is the first-line procedure when an experienced cytopathologist is not immediately available. Purpose: To evaluate the accuracy and complication rate of CT-guided FNAB of lung lesions according to the experience of the cytopathologist on-site. Material and Methods: A total of 321 consecutive biopsies were considered. Immediate cytological assessment was performed by an experienced cytopathologist for the first 165 procedures (group A) and by two training pathologists for the remaining 156 biopsies (group B). At the time of FNAB the pathologist assigned a semiquantitative score (0-3) to each specimen to assess its diagnostic quality. All variables between the two groups were analyzed by chi-square and Student's t test. A P value <0.05 was considered statistically significant. Results: For all procedures, overall diagnostic accuracy was 80% for cytology alone, with no statistical difference between the two groups for diagnostic accuracy and sample score assigned. In all, 75% of the cytological samples (75% group A, 74% group B) obtained a higher score with a specific diagnosis of histotype. A post biopsy pneumothorax was detected in 27% of biopsies (25% group A, 28% group B). Thirteen patients (4.0%) required chest tube insertion for treatment. For all cases, the pneumothorax rate was significantly affected by the number of samples obtained (P=0.02), but not by the pleural punctures (P=0.15). There was no statistically significant difference between the two groups concerning the number of needle passes and complication rate (P>0.05). Conclusion: The efficacy and safety of CT-guided FNAB is not significantly affected by the training level of the cytopathologist

  6. Ultrasound-guided biopsy of the thickened peritoneal reflections: efficacy and diagnostic role in the differential diagnosis of peritoneal tuberculosis and peritoneal carcinomatosis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young Hwan; Ryeom, Hun Kyu; Chung, Tae Gyun; Park, Hyo Yong; Kim, Yong Joo; Kang, Duck Sik [Kyungpook National University Hospital, Taegu (Korea, Republic of)

    2000-08-01

    To evaluate the accuracy and safety of ultrasound-guided biopsy of the thickened peritoneal reflections and to determine the efficacy and diagnostic role of this procedure in the differential diagnosis of peritoneal tuberculosis and peritoneal carcinomatosis. Twenty-seven patients with only mildly thickened (25 mm or less) peritoneal reflections without apparent mass formations, and in whom imaging findings were not diagnostic, underwent ultrasound-guided biopsy. Five-MHz linear or convex linear array transducers were used for ultrasound guidance, and an automated gun with 18-gauge (n=3D23) or 20-gauge (n=3D4) needles for tissue sampling. biopsies were performed on the thickened parietal peritoneum (n=3D9), greater omentum (n=3D11), and small bowel mesentery (n=3D7), and the results were compared with the final diagnosis determined by radiologic/clinical follow-up (n=3D17) or laparoscopic biopsy (n=3D10). Complications and changes in hemoglobin and hematocrit levels after the procedure were evaluated. Specimens adequate for pathologic examination were obtained in all 27 patients. The histopathologic results were metastatic carcinomatosis (n=3D15), peritoneal tuberculosis (n=3D8), and chronic granulomatous inflammation (n=3D4). Specific pathologic diagnosis was obtained in all patients except the four with chronic granulomatous inflammation. Differentiation between benignancy and malignancy was possible in all patients and the histopathologic specific accuracy rate was 100%. No clinically significant complications were observed. In 24 patients with ascites at the site of the biopsy, transient bleeding was observed immediately after the procedure, but this stopped spontaneously within a few minutes. Post-procedural hemoglobin and hematocrit levels were only minimally lower (mean values of 0.9 g/dL and 3.0%, respectively) than pre-procedurally. Ultrasound-guided biopsy of thickened peritoneal reflections is a safe and effective diagnostic procedure and is useful in

  7. Ultrasound-guided biopsy of the thickened peritoneal reflections: efficacy and diagnostic role in the differential diagnosis of peritoneal tuberculosis and peritoneal carcinomatosis

    International Nuclear Information System (INIS)

    Kim, Young Hwan; Ryeom, Hun Kyu; Chung, Tae Gyun; Park, Hyo Yong; Kim, Yong Joo; Kang, Duck Sik

    2000-01-01

    To evaluate the accuracy and safety of ultrasound-guided biopsy of the thickened peritoneal reflections and to determine the efficacy and diagnostic role of this procedure in the differential diagnosis of peritoneal tuberculosis and peritoneal carcinomatosis. Twenty-seven patients with only mildly thickened (25 mm or less) peritoneal reflections without apparent mass formations, and in whom imaging findings were not diagnostic, underwent ultrasound-guided biopsy. Five-MHz linear or convex linear array transducers were used for ultrasound guidance, and an automated gun with 18-gauge (n=3D23) or 20-gauge (n=3D4) needles for tissue sampling. biopsies were performed on the thickened parietal peritoneum (n=3D9), greater omentum (n=3D11), and small bowel mesentery (n=3D7), and the results were compared with the final diagnosis determined by radiologic/clinical follow-up (n=3D17) or laparoscopic biopsy (n=3D10). Complications and changes in hemoglobin and hematocrit levels after the procedure were evaluated. Specimens adequate for pathologic examination were obtained in all 27 patients. The histopathologic results were metastatic carcinomatosis (n=3D15), peritoneal tuberculosis (n=3D8), and chronic granulomatous inflammation (n=3D4). Specific pathologic diagnosis was obtained in all patients except the four with chronic granulomatous inflammation. Differentiation between benignancy and malignancy was possible in all patients and the histopathologic specific accuracy rate was 100%. No clinically significant complications were observed. In 24 patients with ascites at the site of the biopsy, transient bleeding was observed immediately after the procedure, but this stopped spontaneously within a few minutes. Post-procedural hemoglobin and hematocrit levels were only minimally lower (mean values of 0.9 g/dL and 3.0%, respectively) than pre-procedurally. Ultrasound-guided biopsy of thickened peritoneal reflections is a safe and effective diagnostic procedure and is useful in

  8. CT-Guided Percutaneous Biopsy of Intrathoracic Lesions

    Energy Technology Data Exchange (ETDEWEB)

    Lai, Hira; Neyaz, Zafar; Nath, Alok; Borah, Samudra [Sanjay Gandhi Post Graduate Institute of Medical Sciences, Lucknow (India)

    2012-03-15

    Percutaneous CT-guided needle biopsy of mediastinal and pulmonary lesions is a minimally invasive approach for obtaining tissue for histopathological examination. Although it is a widely accepted procedure with relatively few complications, precise planning and detailed knowledge of various aspects of the biopsy procedure is mandatory to avert complications. In this pictorial review, we reviewed important anatomical approaches, technical aspects of the procedure, and its associated complications.

  9. Renal biopsy with 16G needle: a safety study.

    Science.gov (United States)

    Guerrero-Ramos, F; Villacampa-Aubá, F; Jiménez-Alcaide, E; García-González, L; Ospina-Galeano, I A; de la Rosa-Kehrmann, F; Rodríguez-Antolín, A; Passas-Martínez, J; Díaz-González, R

    2014-11-01

    The development of percutaneous renal biopsy as a routinary diagnostic procedure for renal masses is topic of discussion for the last few years. However, this technique has been associated with some complications, although infrequent, and morbidity. Our objective is to carry out a descriptive study about complications and outcomes of orthotopic kidney biopsies with 16 G needle. A retrospective review of 180 orthotopic ultrasound-guided renal biopsies performed in our service among January 2008 to May 2010 was carried out. The procedure was developed using an automated biopsy gun (16G needle). Multiple clinical variables, early post-procedure complications and its management were collected. Complication rates as well as the relationship between risk factors and occurrence of complications were studied. Mean age was 55.8 years. The average number of biopsy cylinders per intervention was 2.49. The overall complication rate was 5.6%. An interventionist attitude derived from complication of the procedure was necessary in only 3 patients (1.67%). No surgical interventions were required and no death as consequence of procedure was registered. No relationship between hypertension (P=.09) previous anticoagulation (P=.099) or previous antiaggregation (P=.603) and complications were demonstrated. In 2.8% of biopsies the material obtained was insufficient for diagnosing. Percutaneous ultrasound-guided renal biopsy with 16G needle is a safe technique with high diagnostic performance. Copyright © 2013 AEU. Published by Elsevier Espana. All rights reserved.

  10. Elemental microanalysis of botanical specimens using the Melbourne Proton Microprobe

    International Nuclear Information System (INIS)

    Mazzolini, A.P.J.; Legge, G.J.F.

    1978-01-01

    A proton microprobe has been used to obtain the distribution of elements of various botanical specimens. This paper presents preliminary results obtained by the irradiation of certain organs of the wheat plant

  11. Renal biopsy in the elderly

    Directory of Open Access Journals (Sweden)

    Javier Robaina

    2016-09-01

    Full Text Available Introduction: Kidney disease is very common among the elderly. Over the last decades, the number of renal biopsies performed on these patients has increased. Objective: This study was carried out to examine the frequency and the clinical-pathological correlation of kidney disease in elderly patients who have had a renal biopsy done. Methods: The clinical presentation of kidney disease and the main histological findings were retrospectively analyzed in patients over 65 who had undergone renal biopsy (n=109 for a period of 12 years. Results: The total number of renal biopsies performed during this period was 871, out of which 109 (12.5% corresponded to patients over 65. The main indications for renal biopsies were nephrotic syndrome (37.6% and kidney failure (34.9%. Microscopic hematuria was found in 59.6% of the patients and high blood pressure in 62.4% of them. The most frequent histological diagnosis was membranous glomerulonephritis (21.1%, followed by extracapillary glomerulonephritis (20.2%. When clinical syndromes and histological findings were compared, the nephrotic syndrome was found to be the main feature of membranous nephropathy (78.3%, of focal segmental glomerulosclerosis (55.6% and of diabetic nephropathy (66.7%. Kidney failure was present in 90% of the cases of extracapillary glomerulonephritis (95.5% pauciimmune or type 3. Microscopic hematuria was the main sign of mesangial prolifeative glomerulonephritis (83.3%. Conclusions: Nephrotic syndrome and kidney failure (especially rapidly progressive renal failure were the main renal biopsy results in this group of patients, bearing close relation to histological findings. The most common types of glomerulonephritis were membranous GN and pauciimmune extracapillary GN. Renal biopsy provides useful information for the diagnosis, prognosis and treatment of kidney disease in the elderly.

  12. Janka hardness using nonstandard specimens

    Science.gov (United States)

    David W. Green; Marshall Begel; William Nelson

    2006-01-01

    Janka hardness determined on 1.5- by 3.5-in. specimens (2×4s) was found to be equivalent to that determined using the 2- by 2-in. specimen specified in ASTM D 143. Data are presented on the relationship between Janka hardness and the strength of clear wood. Analysis of historical data determined using standard specimens indicated no difference between side hardness...

  13. Fatal mediastinal biopsy: How interventional radiology saves the day

    Directory of Open Access Journals (Sweden)

    Y Yaacob

    2012-01-01

    Full Text Available This was a case of a 35-year-old man with mediastinal mass requiring computed tomography (CT-guided biopsy for tissue diagnosis. A posterior approach with an 18-gauge biopsy needle was used to obtain tissue sample. Post biopsy, patient condition deteriorated and multiphase CT study detected active bleeding in arterial phase at the biopsy site with massive hemothorax. Subsequent angiography showed arterial bleeder arising from the apical branch of the right pulmonary artery. Selective endovascular embolization with NBCA (n-Butyl cyanoacrylate was successful. Patient survived the complication. The case highlighted a rare complication in a common radiology procedure and the value of the interventional radiology unit in avoiding a fatal outcome.

  14. Percutaneous Biopsy of Retrobulbar Masses: Anatomical Considerations and MRI Guidance

    Energy Technology Data Exchange (ETDEWEB)

    Edalat, Faramarz, E-mail: faramarz.edalat@gmail.com; Cazzato, Roberto Luigi; Garnon, Julien; Tsoumakidou, Georgia [Nouvel Hôpital Civil (Hôpitaux Universitaires de Strasbourg, HUS), Department of Interventional Radiology (France); Avérous, Gerlinde [CHU Strasbourg Hautepierre, Department of Pathology (France); Caudrelier, Jean; Koch, Guillaume; Gangi, Afshin [Nouvel Hôpital Civil (Hôpitaux Universitaires de Strasbourg, HUS), Department of Interventional Radiology (France)

    2017-04-15

    PurposeObtaining adequate tissue from retrobulbar masses remains a challenge. To this end, a new method of retrobulbar mass biopsy using MRI guidance is presented.Materials and MethodsTwo patients (7- and 71-year-old male) with indeterminate retrobulbar masses underwent bioptic and cytological samplings using MR-compatible 18G and 20–22G needles, and multi-planar MR fluoroscopy. An inferior approach was taken to avoid injury to the optic nerve and ophthalmic arteries.ResultsThe two biopsies were completed without complication. The core biopsy resulted in a final diagnosis, whereas the cytological sampling was non-diagnostic.ConclusionPercutaneous MR-guided retrobulbar mass biopsy proved to be feasible and safe in the two cases described in this report.

  15. [Diagnosis of bone lesions using image guided percutaneous biopsy].

    Science.gov (United States)

    Contreras, Oscar; Burdiles, Alvaro

    2006-10-01

    Percutaneous biopsies have a good sensitivity and specificity for the diagnosis of bone lesions. To report the experience with 270 percutaneous bone lesions biopsies guided with fluoroscopy or computed tomography. Retrospective review of the medical records of 270 patients (mean age 53.4 years, range 4 to 95 years; 134 female) subjected to a percutaneous biopsy of a bone lesion, guided either by computed tomography or fluoroscopy. The final analysis included the tumor type, tumor malignancy, tumor grade and complications of the procedure. One hundred seventy nine lesions were malignant and 91 benign. Of the malignant lesions, 95 were metastatic and 84 were primary. In 3 cases, the initial diagnosis was a false negative (1.1%). Only one patient had a local hematoma after the procedure. Image guided percutaneous biopsy of bone lesions is a safe, effective, fast and economic procedure to obtain a pathological diagnosis of bone lesions.

  16. Barbed micro-spikes for micro-scale biopsy

    Science.gov (United States)

    Byun, Sangwon; Lim, Jung-Min; Paik, Seung-Joon; Lee, Ahra; Koo, Kyo-in; Park, Sunkil; Park, Jaehong; Choi, Byoung-Doo; Seo, Jong Mo; Kim, Kyung-ah; Chung, Hum; Song, Si Young; Jeon, Doyoung; Cho, Dongil

    2005-06-01

    Single-crystal silicon planar micro-spikes with protruding barbs are developed for micro-scale biopsy and the feasibility of using the micro-spike as a micro-scale biopsy tool is evaluated for the first time. The fabrication process utilizes a deep silicon etch to define the micro-spike outline, resulting in protruding barbs of various shapes. Shanks of the fabricated micro-spikes are 3 mm long, 100 µm thick and 250 µm wide. Barbs protruding from micro-spike shanks facilitate the biopsy procedure by tearing off and retaining samples from target tissues. Micro-spikes with barbs successfully extracted tissue samples from the small intestines of the anesthetized pig, whereas micro-spikes without barbs failed to obtain a biopsy sample. Parylene coating can be applied to improve the biocompatibility of the micro-spike without deteriorating the biopsy function of the micro-spike. In addition, to show that the biopsy with the micro-spike can be applied to tissue analysis, samples obtained by micro-spikes were examined using immunofluorescent staining. Nuclei and F-actin of cells which are extracted by the micro-spike from a transwell were clearly visualized by immunofluorescent staining.

  17. Prospective study to evaluate the number and the location of biopsies in rapid urease test for diagnosis of Helicobacter Pylori

    Directory of Open Access Journals (Sweden)

    Antoine Abou Rached

    2017-11-01

    Full Text Available Helicobacter pylori (H. pylori can cause a wide variety of illnesses such as peptic ulcer disease, gastric adenocarcinoma and mucosa-associated lymphoid tissue (MALT lymphoma. The diagnosis and eradication of H. pylori are crucial. The diagnosis of H. pylori is usually based on the rapid urease test (RUT and gastric antral biopsy for histology. The aim of this study is to evaluate the numbers of needed biopsies and their location (antrum/fundus to obtain optimal result for the diagnosis of H. pylori. Three hundred fifty consecutive patients were recruited, 210 fulfill the inclusion criteria and had nine gastric biopsies for the detection of H. pylori infection: two antral for the first RUT (RUT1, one antral and one fundic for the second (RUT2, one antral for the third (RUT3 and two antral with two fundic for histology (HES, Giemsa, PAS. The reading of the 3 types of RUT was performed at 1 hour, 3 hours and 24 hours and biopsies were read by two experienced pathologists not informed about the result of RUT. Results of RUT were considered positive if H. pylori was found on histology of at least one biopsy. The RUT1 at 1h, 3h and 24h has a sensitivity of 72%, 82% and 89% and a specificity of 100%, 99% and 87% respectively. The positive predictive value (PPV was 100%, 99% and 85% respectively and the negative predictive value (NPV of 81%, 87% and 90%. The RUT2 at 1h, 3h and 24h, respectively, had a sensitivity of 86%, 87% and 91% and a specificity of 99%, 97% and 90%. The PPV was 99%, 96% and 88% and NPV of 89%, 90%, 94%. The RUT3 at 1h, 3h and 24h, respectively, had a sensitivity of 70%, 74% and 84% and a specificity of 99%, 99% and 94%. The PPV was 99%, 99% and 92% and NPV of 79%, 81% and 87%. The best sensitivity and specificity were obtained for RUT1 read at 3h, for RUT2 read 1h and 3h, and the RUT3 read at 24h.This study demonstrates that the best sensitivity and specificity of rapid test for urease is obtained when fundic plus antral biopsy

  18. Intrinsic material properties of trabecular bone by nanoindentation testing of biopsies taken from healthy women before and after menopause.

    Science.gov (United States)

    Polly, Benjamin J; Yuya, Philip A; Akhter, Mohammed P; Recker, Robert R; Turner, Joseph A

    2012-04-01

    Postmenopausal osteoporosis in women is characterized by an increase in bone fragility and risk of fracture. In addition to transmenopausal decline in three-dimensional trabecular bone architecture, changes in intrinsic material properties (local stiffness, damping, and hardness) may contribute to increased bone fragility. In this study, nanoindentation was used to quantify transmenopausal changes in the intrinsic properties of trabecular bone. Paired transilial biopsy specimens were used from a previously reported study in which bone biopsies were obtained from women prior to menopause (premenopausal, age 49.0 ± 1.9) and at 12 months past the last menstrual period (postmenopausal, age 54.6 ± 2.2). Elastic and viscoelastic material properties of the trabecular bone were measured using quasi-static and dynamic nanoindentation techniques, respectively. Paired Student's t tests (n = 15) were performed to assess the significance of the measured intrinsic properties. Trabecular bone microarchitecture is compromised in postmenopausal women, and although this loss is associated with a trend toward reduction in some intrinsic properties (storage modulus), we found no statistically significant changes in bone intrinsic properties between healthy pre- and postmenopausal biopsies in the quasi-static results and frequency-averaged dynamic results.

  19. Image-guided biopsy in patients with suspected ovarian carcinoma: a safe and effective technique?

    Energy Technology Data Exchange (ETDEWEB)

    Griffin, Nyree; Grant, Lee A.; Freeman, Susan J.; Berman, Laurence H.; Sala, Evis [Addenbrooke' s Hospital, Department of Radiology, Cambridge (United Kingdom); Jimenez-Linan, Mercedes [Addenbrooke' s Hospital, Department of Histopathology, Cambridge (United Kingdom); Earl, Helena; Ahmed, Ahmed Ashour; Crawford, Robin; Brenton, James [Addenbrooke' s Hospital, Department of Oncology, Cambridge (United Kingdom)

    2009-01-15

    In patients with suspected advanced ovarian carcinoma, a precise histological diagnosis is required before commencing neo-adjuvant chemotherapy. This study aims to determine the diagnostic accuracy and complication rate of percutaneous biopsies performed under ultrasound or computed tomography guidance. Between 2002 to 2007, 60 consecutive image-guided percutaneous biopsies were performed in patients with suspected ovarian cancer. The following variables were recorded: tissue biopsied, imaging technique, experience of operator, biopsy needle gauge, number of passes, complications, and final histology. Forty-seven patients had omental biopsies, 12 pelvic mass biopsies, and 1 para-aortic lymph node biopsy. Thirty-five biopsies were performed under ultrasound, 25 under computed tomography guidance. Biopsy needle gauges ranged from 14-20 swg with two to five passes for each patient. There were no complications. Histology was obtained in 52 (87%) patients. Percutaneous image-guided biopsy of peritoneal disease or pelvic mass is safe with high diagnostic accuracy. The large-gauge biopsy needle is as safe as the small gauge needle, but has the added value of obtaining tissue samples for immunohistochemistry and genomic studies. (orig.)

  20. Mixed germ cell tumor of mediastinum/lung masquerading as hemangioma in fine needle biopsy

    Directory of Open Access Journals (Sweden)

    Rathna Nuti

    2013-01-01

    Full Text Available The histological predominance of one component in a germ cell tumor can lead to a mistaken diagnosis. Here, we describe a mediastinal teratoma with predominant vascular proliferation (>90% which on fine needle biopsy was diagnosed as a pulmonary hemangioma. Later, resection specimen revealed other components constituting ~4%, changing the diagnosis while illustrating theimportance of careful evaluation. A 37-year-old Caucasian male with shortness of breath, weight loss, and history of recently resolved pneumonia was diagnosed with hemangioma, after a computed tomography guided fine needle biopsy of a -16.3-cm mediastinal pulmonary mass revealed abundant benign vascular elements. Following tumor excision, ~94% of the sample exhibited predominant vascular elementsThe mass also exhibited rare focal areas of malignant epithelium in a reticular arrangement and undifferentiated pleomorphic cells associated with vascular invasion. These atypical epithelial cells were positive for CD30, pan CK, AFP, β-HCG and CD 117, thusprocuring a diagnosis of mediastinal mixed germ cell tumor. Although mixed germ cell tumors consist of various tissue types, diagnosis can be easily overlooked if one component dominates. Therefore, obtaining adequate representative neoplasm samples, and sectioning the samples thoroughly, searching for coexisting tissue types is critical for accurate diagnosis.

  1. Clinical studies on diabetic myocardial disease using exercise testing with myocardial scintigraphy and endomyocardial biopsy

    International Nuclear Information System (INIS)

    Genda, A.; Mizuno, S.; Nunoda, S.

    1986-01-01

    Nine diabetics without significant coronary stenosis participated in an exercise testing protocol with thallium-201 myocardial scintigraphy. Endomyocardial biopsy of right ventricle was also obtained. There were 4 patients with abnormal perfusion (positive group) and 5 patients with normal perfusion (negative group). All cases of the positive group were familial diabetics and there was only one case of dietary treatment, whereas in the negative group, there were only 2 cases of familial diabetics and 3 cases receiving dietary treatment. No statistical differences between the positive and negative groups were observed for the data of exercise performance and hemodynamic parameters in cardiac catheterization at rest. However, the mean ejection fraction in the positive group (62 +/- 13%) was significantly lower than in the negative group (77 +/- 4%). In both groups, the mean diameter of myocardial cells and the mean percent fibrosis of biopsy specimens showed significant increases compared with the control group. The mean percent fibrosis in the positive group (24.1 +/- 8.5%) compared with that in the negative group (16.5 +/- 5.9%) showed a tendency to increase. It is suggested that the abnormal perfusion of thallium-201 in the positive group indicates subclinically a pathological change of microcirculation caused by diabetes mellitus

  2. High grade squamous intraepithelial lesion in inmates from Ohio: cervical screening and biopsy follow-up

    Directory of Open Access Journals (Sweden)

    Rofagha Soraya

    2006-01-01

    Full Text Available Abstract Background Cervical carcinoma remains the second leading cause of cancer death in women worldwide and sexual behavior is regarded as the main contributing factor. We studied cervical cytology screening with surgical biopsy follow-up in women prisoners and compared the findings to those in the general population. Methods We reviewed 1024 conventional cervical smears, 73 cervical biopsies and 2 loop electrosurgical excision procedure (LEEP specimens referred to us from the Correctional Center in Columbus, Ohio during a 12-month period. The results were compared to 40,993 Pap smears from the general population for the same 12-month period. Results High grade squamous intraepithelial lesion (HGSIL was diagnosed in 1.3% of the cervical smears from the inmate population versus 0.6% in the general population (p < 0.01. The unsatisfactory rate was 1.6% compared to 0.3% in the general population (p < 0.01. Among the study population, follow-up tissue diagnosis was obtained in 24.3% of the abnormal cytology results (ASCUS, LGSIL, and HGSIL. Of the HGSIL Pap smears, 61.5% had a subsequent tissue diagnosis. Thirty-nine biopsies (52% of the all inmate biopsies and LEEP showed CIN II/III (cervical intraepithelial neoplasia II/III. Eight of these thirty-nine follow-up biopsies diagnosed as CIN II/III had a previous cervical cytology diagnosis of ASCUS. The average age for HGSIL was 30.5 years (S.D. = 5.7 and for low grade squamous intraepithelial lesion (LGSIL was 27.2 years (S.D. = 6.1. Conclusion A significantly higher prevalence of HGSIL cervical cytology and unsatisfactory smears was encountered in female inmates, with tissue follow-up performed in less than two thirds of the patients with HGSIL. These results are in keeping with data available in the literature suggesting that the inmate population is high-risk and may be subject to less screening and tissue follow-up than the general population. Clinicians should proceed with urgency to improve

  3. Clinical evaluation of percutaneous transthoracic needle core-biopsy under CT guidance (with 522 cases reports)

    International Nuclear Information System (INIS)

    Li Chengzhou; Wu Chungen; Ding Yuegen; Jia Ningyang; Zhang Dianbo; Liu Shiyuan; Xiao Xiangsheng; Jiang Qingjun

    2008-01-01

    Objective: To evaluate the diagnostic accuracy, sensitivity, specificity and complications of transthoracic needle core-biopsy of pulmonary lesions under CT guidance, and to compare with those biopsies under fine-needle aspiration. Methods: 522 patients who underwent transthoracic needle biopsy under CT guidance were enrolled including 467 pulmonary nodules or masses, and 55 with diffuse pulmonary diseases, but no pleural or chest wall lesions were enrolled. Both histopathologic and cytopathologic analyses were involved together with positive predictive value, sensitivity, specificity, accuracy, false- negative rate and complication (pneumothorax) were analyzed as well. Results: 476 cases with obtained enough specimens got accurate pathological diagnosis of 91.2% total acuracy (476/522). 301 cases were proved to be malignant tumors, including adenocarcinoma (n=107), squamous cell carcinoma (n=84), malignancy with no specified type (n=59), small cell lung cancer(n=16),metastatic lesiions (n=22), lower-degree malignant tumors (n=3), pulmonary sarcoma(n=3), bronchioloalveolar carcinoma(n=2), and suspected malignancy (n=5). 17 cases were suspected of cacinomatous charge, whereas they were confirmed to be benign critics eventually. 129 cases hadn't been found carcinomatous cells, which could be classified as specific-negative results in 102 cases, non-specific results 73, and the remained 29 cases were assigned to be false-negative and later proved to be cancer via operation and f011owed-up. Positive predictive value was 94.7%(301/(301+17)); sensitivity and specificity were 91.2%(301/(301+29))and 91.1% (175/(175+17)), respectively. False-negative rate was 14.2% (29/204). Pneumothorax occured in 54 cases with the rate of 10.3%(54/522), but chest tube placement and drainage were established in only eight cases(1.5%). Pulmonary hemorrhage and hemoptysis ocurred in 46 and 32 cases. One patient had hemoptysis over 50 mi,but no additional treatment was conducted. Conclusion

  4. Testicular biopsy in prepubertal boys

    DEFF Research Database (Denmark)

    Faure, Alice; Bouty, Aurore; O'Brien, Mike

    2016-01-01

    for the preservation of fertility after gonadotoxic chemotherapy - even for prepubertal boys - are emerging. Cryopreservation of testicular tissue samples for the preservation of fertility - although still an experimental method at present - is appealing in this context. In our opinion, testicular biopsy...

  5. Gram stain of tissue biopsy

    Science.gov (United States)

    ... suspected. Normal Results Whether there are bacteria, and what type there are, depends on the tissue being biopsied. Some tissues in the body are ... about the meaning of your specific test results. What Abnormal Results Mean ... results usually mean there is an infection in the tissue. More tests, such as culturing the tissue that ...

  6. M. tuberculosis in Lymph Node Biopsy Paraffin-Embedded Sections

    Directory of Open Access Journals (Sweden)

    Abdurehman Eshete

    2011-01-01

    Full Text Available Background. Tuberculosis lymphadenitis is one of the most common forms of all extrapulmonary tuberculosis. Objective. To evaluate the magnitude of M. tuberculosis from lymph node biopsy paraffin-embedded sections among suspected patients visiting the Jimma University Specialized Hospital. Method. A cross-sectional study design of histological examination among lymph node biopsy paraffin-embedded sections by Ziehl-Neelsen and hematoxylin/eosin staining technique was conducted from December, 2009, to October, 2010, at the Department of Medical Laboratory Science and Pathology. Result. Histopathological examination of the specimens by hematoxylin and eosin staining technique revealed the presence of granulomas. But for the caseation and necrosis they were present in 85% cases of nodal tissue biopsies. From those, 56.7% were from females. The presence of acid-fast bacilli was microscopically confirmed by ZN staining in 37 (61.7% of the nodal tissue biopsies. Conclusion and Recommendation. Tuberculosis lymphadenitis is significantly more common in females. Hence, attention should be given for control and prevention of extrapulmonary tuberculosis.

  7. Cost Analysis of Channeled, Distal Chip Laryngoscope for In-office Laryngopharyngeal Biopsies.

    Science.gov (United States)

    Marcus, Sonya; Timen, Micah; Dion, Gregory R; Fritz, Mark A; Branski, Ryan C; Amin, Milan R

    2018-02-19

    Given that financial considerations play an increasingly prominent role in clinical decision-making, we sought (1) to determine the cost-effectiveness of in-office biopsy for the patient, the provider, and the health-care system, and (2) to determine the diagnostic accuracy of in-office biopsy. Retrospective, financial analyses were performed. Patients who underwent in-office (Current Procedural Terminology Code 31576) or operative biopsy (CPT Code 31535) for laryngopharyngeal lesions were included. Two financial analyses were performed: (1) the average cost of operating room (OR) versus in-office biopsy was calculated, and (2) a break-even analysis was calculated to determine the cost-effectiveness of in-office biopsy for the provider. In addition, the diagnostic accuracy of in-office biopsies and need for additional biopsies or procedures was recorded. Of the 48 patients included in the current study, 28 underwent in-office biopsy. A pathologic sample was obtained in 26 of 28 (92.9%) biopsies performed in the office. Of these patients, 16 avoided subsequent OR procedures. The average per patient cost was $7000 and $11,000 for in-office and OR biopsy, respectively. Break-even analysis demonstrated that the provider could achieve a profit 2 years after purchase of the necessary equipment. In-office laryngopharyngeal biopsies are accurate and, overall, more cost-effective than OR biopsies. Purchase of the channeled, distal chip laryngoscope and biopsy forceps to perform in-office biopsies can be profitable for a provider with a videolaryngoscopy tower. In-office biopsy should be considered the initial diagnostic tool for suspected laryngopharyngeal malignancies noted on videolaryngoscopy. Copyright © 2018 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  8. Retrospective study comparing six - and twelve-core prostate biopsy in detection of prostate cancer

    Directory of Open Access Journals (Sweden)

    Motoi Tobiume

    2008-02-01

    Full Text Available OBJECTIVE: We compared the safety and efficacy of the 12-core biopsy with those of the conventional systematic 6-core biopsy with PSA levels between 4.1 and 20.0 ng/mL. MATERIALS AND METHODS: This study included 428 patients who underwent a 6-core biopsy and 128 patients who underwent a 12-core biopsy. Biopsies were performed transrectally under ultrasound guidance. The 12-core biopsy scheme involved obtaining 6 far lateral cores. RESULTS: For patients with PSA level between 4.1 and 10.1 ng/mL, 47 of the 265 patients who underwent 6-core biopsy and 32 of the 91 patients who underwent a12-core biopsy were diagnosed with prostate cancer (p = 0.0006. Among the patients with a PSA level between 10.1 and 20.0 ng/mL, 48 of 163 patients who underwent the 6-core biopsy and 16 of 37 patients who underwent the 12-core biopsy were diagnosed with prostate cancer (p = 0.0606. Three of the 95 patients who were diagnosed with prostate cancer through the 6-core biopsy and 12 of the 48 patients who were diagnosed through the 12-core biopsy had cancer located in the anterior apex. The 12-core biopsy increased the diagnostic rate in the apex (p = 0.001. No statistically significant differences were found in incidence of complications. CONCLUSION: We concluded that the 12-core biopsy is a safe and more effective procedure for increasing the diagnostic rate of prostate cancer than the 6-core biopsy in patients with PSA level between 4.1 and 10.0 ng/mL, and the most useful anatomical area to be added was found to be cores from the anterior apex.

  9. When to biopsy seminal vesicles.

    Science.gov (United States)

    Panach-Navarrete, J; García-Morata, F; Hernández-Medina, J A; Martínez-Jabaloyas, J M

    2015-05-01

    The involvement of seminal vesicles in prostate cancer can affect the prognosis and determine the treatment. The objective of this study was to determine whether we could predict its infiltration at the time of the prostate biopsy to know when to indicate the biopsy of the seminal vesicles. observational retrospective study of 466 patients who underwent seminal vesicle biopsy. The indication for this biopsy was a prostate-specific antigen (PSA) level greater than 10 ng/ml or an asymmetric or obliterated prostatoseminal angle. The following variables were included in the analysis: PSA level, PSA density, prostate volume, number of cores biopsied, suspicious rectal examination, and preservation of the prostatoseminal angle, studying its relationship with the involvement of the seminal vesicles. Forty-one patients (8.8%) had infiltrated seminal vesicles and 425 (91.2%) had no involvement. In the univariate analysis, the cases with infiltration had a higher mean PSA level (P 19.60 ng/dL (P < .01) and 2.95 times higher if there is a suspicious rectal examination (P = .014). Furthermore, this probability increases by 1.04 times for each unit of prostate volume lower (P < .01). The ROC curves showed maximum sensitivity and specificity at 19.6 ng/mL for PSA and 0.39 for PSA density. In this series, greater involvement of seminal vesicles was associated with a PSA level ≥20 ng/ml, a suspicious rectal examination and a lack of prostatoseminal angle preservation. Copyright © 2014 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  10. Effectiveness of core biopsy for screen-detected breast lesions under 10 mm: implications for surgical management.

    Science.gov (United States)

    Farshid, Gelareh; Downey, Peter; Pieterse, Steve; Gill, P Grantley

    2017-09-01

    Technical advances have improved the detection of small mammographic lesions. In the context of mammographic screening, accurate sampling of these lesions by percutaneous biopsy is crucial in limiting diagnostic surgical biopsies, many of which show benign results. Women undergoing core biopsy between January 1997 and December 2007 for core histology, 345 women (43.0%) were immediately cleared of malignancy and 300 (37.4%) were referred for definitive cancer treatment. A further 157 women (19.6%) required diagnostic surgical biopsy because of indefinite or inadequate core results or radiological-pathological discordance, and one woman (0.1%) needed further imaging in 12 months. The open biopsies were malignant in 46 (29.3%) cases. The positive predictive value of malignant core biopsy was 100%. The negative predictive value for benign core results was 97.7%, and the false-negative rate was 2.6%. The lesion could not be visualized after core biopsy in 5.1% of women and in 4.0% of women with malignant core biopsies excision specimens did not contain residual malignancy. Excessive delays in surgery because of complications of core biopsy were not reported. Even at this small size range, core biopsy evaluation of screen-detected breast lesions is highly effective and accurate. A lesion miss rate of 3.1% and under-representation of lesions on core samples highlight the continued need for multidisciplinary collaboration and selective use of diagnostic surgical biopsy. © 2015 Royal Australasian College of Surgeons.

  11. stomach contents of a specimen of proteles cristatus from angola

    African Journals Online (AJOL)

    north of Sa da Bandeira, Angola (at about 140. SO' Sjl3° 35' E). The skin and skull were deposited in the Alexander McGregor Memorial Museum. Kimberley, Cape (Collectors No. 276a). The stomach contents of this specimen are detailed in. Table I. The habitat where the specimen was obtained was degraded ...

  12. Biopsy location for direct immunofluorescence in patients with suspected bullous pemphigoid impacts probability of a positive test result.

    Science.gov (United States)

    Sladden, Chris; Kirchhof, Mark G; Crawford, Richard I

    2014-11-01

    Bullous pemphigoid (BP) is an autoimmune polymorphic skin disease characterized by erythematous papules and plaques and tense bullae. A skin biopsy for direct immunofluorescence (DIF) is used to detect autoantibodies and complement proteins. We sought to determine which location would provide the highest probability of obtaining a positive DIF result. We undertook a retrospective chart review of 1,423 DIF biopsies. Biopsies with a clinical suspicion of BP were designated as either lesional, perilesional, or indeterminate. Fifty percent of lesional DIF biopsies were positive, whereas 22% of perilesional and 12% of indeterminate biopsies had a positive DIF result. The odds ratio of a positive DIF from a lesional versus perilesional biopsy site was found to be 3.45 (95% CI 1.44-8.29). Clinicians are more likely to obtain a positive DIF result from a lesional nonbullous skin biopsy than from a perilesional or normal skin biopsy.

  13. [Incidence of lamellae annulatae in testicular biopsy material].

    Science.gov (United States)

    Vydra, G

    1980-07-01

    Incidence of lamellae annulatae has been studied in testis biopsy specimens of 52 patients with varicocele, atrophia of testis, agenesia of ductus deferens and Klinefelter syndrome. Biopsies were performed between September 1977 and June 1979. Lamellae annulatae have been observed in every case except two. These observations seem to confirm the hypothesis, according to which lamellae annulate of germinal cells take their origin from the nuclear membranes. Their localization in Sertoli cells seems to contradict to this theory. Lamellae annulatae of germinal cells have a longitudinal, parallel arrangement. In Sertoli cells most of them appear to be concentric structure. Lamellae annulatae in accordance with data reported in literature in Leydig cells have not been found.

  14. Freehand biopsy guided by electromagnetic needle tracking

    DEFF Research Database (Denmark)

    Ewertsen, C; Nielsen, Marie Kristina Rue; Nielsen, M Bachmann

    2011-01-01

    To evaluate the overall accuracy and time spent on biopsy guided by electromagnetic needle tracking in a phantom compared with the standard technique of US-guided biopsy with an attached steering device. Furthermore, to evaluate off-plane biopsy guided by needle tracking.......To evaluate the overall accuracy and time spent on biopsy guided by electromagnetic needle tracking in a phantom compared with the standard technique of US-guided biopsy with an attached steering device. Furthermore, to evaluate off-plane biopsy guided by needle tracking....

  15. Microarray analysis for delineating the gene expression in biopsies of gastrocnemius muscle of patients with chronic critical limb ischaemia compared with non-ischaemic controls.

    Science.gov (United States)

    Freund, Daniel; Brilloff, Silke; Ghazy, Tamer; Kirschner, Stephan; Gäbel, Gabor; Hinterseher, Irene; Weiss, Norbert; Mahlmann, Adrian

    2018-03-20

    Microarray analysis has been carried out in this pilot study to compare delineated gene expression profiles in the biopsies of skeletal muscle taken from patients with chronic critical limb ischaemia (CLI) and non-ischaemic control subjects. Biopsy of gastrocnemius muscle was obtained from six patients with unreconstructed CLI referred for surgical major amputation. As control, biopsies of six patients undergoing elective knee arthroplasty without evidence of peripheral arterial occlusive disease were taken. The differences in gene expression associated with angiogenic processes in specimens obtained from ischaemic and non-ischaemic skeletal muscle were confirmed by quantitative real-time polymerase chain reaction (PCR) analysis. Compared with non-ischaemic skeletal muscle biopsy of chronic-ischaemic skeletal muscle contained 55 significantly up-regulated and 45 down-regulated genes, out of which 64 genes had a known genetic product ((Author, please revise sentence)). Tissue samples of ischaemic muscle were characterized by increased expression of cell survival factors (e. g. tissue factor pathway inhibitor 2) in combination with reduced expression of cell proliferation effectors (e. g. microfibrillar-associated protein 5 and transferrin receptor). The expression of growth factors (e. g. early growth response 3 and chemokine receptor chemokine C-X-C motif ligand 4) which play a central role in arterial and angiogenic processes and anti-angiogenetic factors (e. g. pentraxin 3) were increased in chronic ischaemic skeletal muscle. An increased expression of extracellular matrix proteins (e. g. cysteine-rich angiogenic inducer 61) was also observed. Gene expression profiles in biopsies of gastrocnemius muscle in patients with chronic critical limb ischaemia showed an increase in pro-survival factors, extracellular matrix protein deposition, and impaired proliferation, compared with non-ischaemic controls. Further studies are required to analyse the endogenous repair

  16. Technique of endoscopic biopsy of islet allografts transplanted into the gastric submucosal space in pigs.

    Science.gov (United States)

    Fujita, Minoru; McGrath, Kevin M; Bottino, Rita; Dons, Eefje M; Long, Cassandra; Kumar, Goutham; Ekser, Burcin; Echeverri, Gabriel J; Hata, Jiro; Haruma, Ken; Cooper, David K C; Hara, Hidetaka

    2013-01-01

    Currently, islet cells are transplanted into the liver via portal vein infusion. One disadvantage of this approach is that it is not possible to adequately biopsy the islets in the liver to assess for rejection. Islet transplantation (Tx) into the gastric submucosal space (GSMS) can be performed endoscopically and has the potential advantage of histological evaluation by endoscopic biopsy. The aim of this study was to determine whether a representative allograft sample could be obtained endoscopically. We performed islet Tx into the GSMS in nonimmunosuppressed pigs using simple endoscopic submucosal injection. Islets were transplanted at four sites. Endoscopic ultrasonography and biopsy of the transplanted islets at two sites by modified endoscopic submucosal dissection were carried out successfully in all pigs 5 days after islet Tx. Tissue obtained at both biopsy and necropsy (including full-thickness sections of the gastric wall around the sites of the remaining islets and biopsies) were examined by histology and immunohistochemistry to confirm the presence of the islet grafts and any features of rejection. Representative allograft sampling was successfully obtained from all biopsy sites. All biopsies included islets with insulin-positive staining. There was significant CD3(+) and CD68(+) cell infiltration in the islet masses obtained at biopsy and from sections taken at necropsy, with similar histopathological features. Endoscopic biopsy of islet allografts in the GSMS is feasible, provides accurate histopathological data, and would provide a significant advance if translated into clinical practice.

  17. MR and CT Imaging to Optimize CT-Guided Biopsies in Suspected Spondylodiscitis.

    Science.gov (United States)

    Foreman, Sarah C; Schwaiger, Benedikt J; Gempt, Jens; Jungmann, Pia M; Kehl, Victoria; Delbridge, Claire; Wantia, Nina; Zimmer, Claus; Kirschke, Jan S

    2017-03-01

    The diagnostic value of computed tomography (CT)-guided spinal biopsy in patients with suspected spondylodiscitis is reported inconsistently in the literature. Our aim was to evaluate associations between procedural, clinical, and imaging parameters and the diagnostic yield of CT-guided spinal biopsy. One hundred and two procedures performed in 87 patients with clinically suggested spondylodiscitis were analyzed retrospectively. Preprocedural magnetic resonance (MR) and CT images were evaluated regarding signal alterations, vertebral destruction, and soft-tissue involvement. The position of the biopsy needle in correlation with MR imaging findings was assessed. Patient characteristics and clinical details were noted. Parameters were compared in patients with positive and negative microbiological and histologic results. Following microbiologic and histologic analysis, infectious spondylodiscitis was diagnosed in 29 and 23 biopsies, respectively. Microbiology results were significantly higher in biopsy specimens with central needle positioning within contrast enhancing tissue in correlation with the MR images (36% vs. 7%; P = 0.005). Biopsy specimens positioned in fluid-equivalent hyperintense discs in T2-weighted sequences yielded significantly lower microbiology results (6% vs. 33%; P = 0.036). Purely lytic endplate destruction and mixed vertebral density as shown by CT increased microbiology results (60% vs. 24%; P = 0.028). Previous antibiotic treatment for any cause did not influence microbiology yields significantly (P = 0.232). MR imaging is mandatory to determine the optimal biopsy position. No clinical or imaging parameter could rule out a positive biopsy result and thus omit an unnecessary procedure. Biopsy should not be avoided if antibiotic treatment has previously been administered. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. A comparison of two techniques: Open and percutaneous biopsies of thoracolumbar vertebral body lesions

    Directory of Open Access Journals (Sweden)

    Furkan Yapici

    2015-01-01

    Full Text Available Aim: The purpose of this article is to compare the similarity of initial radiological diagnosis and pathological diagnosis between thoracal and lumbar vertebral bodies and the adequacy and the reliability of open and percutaneous biopsies performed via transpedicular approach in the lesions located in vertebral bodies. Materials and Methods: Thirty-three patients who had undergone transpedicular biopsy for vertebral body lesions were retrospectively evaluated. Seventeen patients were diagnosed by percutaneous transpedicular biopsy (11 in the lumbar vertebrae, 6 in the thoracal vertebrae. Sixteen patients were diagnosed by open transpedicular biopsy (9 in the lumbar vertebrae, 7 in the thoracal vertebrae. Results: The similarity ratio between the initial radiological diagnosis and the final pathological diagnosis was 71.4% in the open biopsy and was 69.2% in the percutaneous biopsy (P > 0.05. The similarity ratio between the initial radiological diagnosis and the final pathological diagnosis was 66.7% in the lumbar region and was 77.8% in the thoracal region (P > 0.05. For percutaneous biopsy group, the similarity ratio was 72.7% in the lumbar region and was 66.7% in the thoracal region (P > 0.05. For open biopsy group, the similarity ratio was 62.5% in the lumbar region and 83.3% in the thoracal region (P > 0.05. No complication was observed. Conclusion: Specimen adequacy of open biopsy was higher than percutaneous biopsy. Particularly, the open thoracal biopsy has provided the highest similarity ratio between the initial radiological diagnosis and the final pathological diagnosis.

  19. Paraffin-based immunohistochemistry in the evaluation of glomerular diseases in renal biopsies

    International Nuclear Information System (INIS)

    Rathore, M.U.; Khadim, M.T.; Atique, M.

    2012-01-01

    Objective: To determine sensitivity and specificity of paraffin-based immunohistochemistry in the evaluation of glomerular diseases in renal biopsies using immunofluorescence as gold standard. Study Design: Cross-sectional analytical study. Place and Duration of Study: Department of Histopathology, Armed Forces Institute of Pathology, Rawalpindi, from August 2008 to August 2009. Methodology: Seventy renal biopsy specimens fulfilling the inclusion criteria for light microscopy and immuno-fluorescence during the study period were evaluated. Antibodies to immunoglobulins (IgG, IgA, and IgM) and components of complement system (C3) were applied on 70 formalin-fixed paraffin-embedded renal biopsy specimens previously classified by means of light microscopy and immunofluorescence (IF). Staining for these antibodies was recorded as positive and negative for immunohistochemistry (IHC) and IF in paired proportions presuming IF as gold standard test. The sensitivity, specificity, positive predictive value and negative predictive value of individual antibody were calculated. Results: Of 70 patients, mean age was 33 +- 18 years ranging from 2 to 80 years. Forty five (64%) were males and 25 (36%) were females. The sensitivity, specificity and predictive values of individual antibodies to IgG, IgA, IgM and C3 were very low and generally in the range of 40 - 60%. Conclusion: The sensitivity, specificity and predictive values of immunohistochemistry on formalin-fixed paraffin-embedded renal biopsy specimens were very low and therefore, not suitable for evaluation of renal biopsies in current circumstances. (author)

  20. Manufacturing of Plutonium Tensile Specimens

    Energy Technology Data Exchange (ETDEWEB)

    Knapp, Cameron M [Los Alamos National Laboratory

    2012-08-01

    Details workflow conducted to manufacture high density alpha Plutonium tensile specimens to support Los Alamos National Laboratory's science campaigns. Introduces topics including the metallurgical challenge of Plutonium and the use of high performance super-computing to drive design. Addresses the utilization of Abaqus finite element analysis, programmable computer numerical controlled (CNC) machining, as well as glove box ergonomics and safety in order to design a process that will yield high quality Plutonium tensile specimens.

  1. Biopsy

    Science.gov (United States)

    ... What is the FOD? Foundation Levels of Giving Governance By-Laws Committees Committee Service Conflict of Interest ... These are often done to remove a small growth and confirm its nature at the same time. ...

  2. DNA extraction from herbarium specimens.

    Science.gov (United States)

    Drábková, Lenka Záveská

    2014-01-01

    With the expansion of molecular techniques, the historical collections have become widely used. Studying plant DNA using modern molecular techniques such as DNA sequencing plays an important role in understanding evolutionary relationships, identification through DNA barcoding, conservation status, and many other aspects of plant biology. Enormous herbarium collections are an important source of material especially for specimens from areas difficult to access or from taxa that are now extinct. The ability to utilize these specimens greatly enhances the research. However, the process of extracting DNA from herbarium specimens is often fraught with difficulty related to such variables as plant chemistry, drying method of the specimen, and chemical treatment of the specimen. Although many methods have been developed for extraction of DNA from herbarium specimens, the most frequently used are modified CTAB and DNeasy Plant Mini Kit protocols. Nine selected protocols in this chapter have been successfully used for high-quality DNA extraction from different kinds of plant herbarium tissues. These methods differ primarily with respect to their requirements for input material (from algae to vascular plants), type of the plant tissue (leaves with incrustations, sclerenchyma strands, mucilaginous tissues, needles, seeds), and further possible applications (PCR-based methods or microsatellites, AFLP).

  3. Magnetic Resonance and Ultrasound Image Fusion Supported Transperineal Prostate Biopsy Using the Ginsburg Protocol: Technique, Learning Points, and Biopsy Results.

    Science.gov (United States)

    Hansen, Nienke; Patruno, Giulio; Wadhwa, Karan; Gaziev, Gabriele; Miano, Roberto; Barrett, Tristan; Gnanapragasam, Vincent; Doble, Andrew; Warren, Anne; Bratt, Ola; Kastner, Christof

    2016-08-01

    Prostate biopsy supported by transperineal image fusion has recently been developed as a new method to the improve accuracy of prostate cancer detection. To describe the Ginsburg protocol for transperineal prostate biopsy supported by multiparametric magnetic resonance imaging (mpMRI) and transrectal ultrasound (TRUS) image fusion, provide learning points for its application, and report biopsy results. The article is supplemented by a Surgery in Motion video. This single-centre retrospective outcome study included 534 patients from March 2012 to October 2015. A total of 107 had no previous prostate biopsy, 295 had benign TRUS-guided biopsies, and 159 were on active surveillance for low-risk cancer. A Likert scale reported mpMRI for suspicion of cancer from 1 (no suspicion) to 5 (cancer highly likely). Transperineal biopsies were obtained under general anaesthesia using BiopSee fusion software (Medcom, Darmstadt, Germany). All patients had systematic biopsies, two cores from each of 12 anatomic sectors. Likert 3-5 lesions were targeted with a further two cores per lesion. Any cancer and Gleason score 7-10 cancer on biopsy were noted. Descriptive statistics and positive predictive values (PPVs) and negative predictive values (NPVs) were calculated. The detection rate of Gleason score 7-10 cancer was similar across clinical groups. Likert scale 3-5 MRI lesions were reported in 378 (71%) of the patients. Cancer was detected in 249 (66%) and Gleason score 7-10 cancer was noted in 157 (42%) of these patients. PPV for detecting 7-10 cancer was 0.15 for Likert score 3, 0.43 for score 4, and 0.63 for score 5. NPV of Likert 1-2 findings was 0.87 for Gleason score 7-10 and 0.97 for Gleason score ≥4+3=7 cancer. Limitations include lack of data on complications. Transperineal prostate biopsy supported by MRI/TRUS image fusion using the Ginsburg protocol yielded high detection rates of Gleason score 7-10 cancer. Because the NPV for excluding Gleason score 7-10 cancer was very

  4. Ultrasound guided percutaneous fine needle aspiration biopsy ...

    African Journals Online (AJOL)

    2011-06-15

    )-guided percutaneous fine needle aspiration biopsy (PFNAB)/US-guided percutaneous needle core biopsy (PNCB) of abdominal lesions is efficacious in diagnosis, is helpful in treatment choice, to evaluate whether various ...

  5. Ultrasound guided percutaneous fine needle aspiration biopsy ...

    African Journals Online (AJOL)

    )-guided percutaneous fine needle aspiration biopsy (PFNAB)/US-guided percutaneous needle core biopsy (PNCB) of abdominal lesions is efficacious in diagnosis, is helpful in treatment choice, to evaluate whether various other investigations ...

  6. Histological evidence of testicular dysgenesis in contralateral biopsies from 218 patients with testicular germ cell cancer

    DEFF Research Database (Denmark)

    Hoei-Hansen, Christina E; Holm, Mette; Rajpert-De Meyts, Ewa

    2003-01-01

    retrospectively. Two hundred and eighteen specimens were subsequently included in this study, after 63 patients who did not meet inclusion criteria had to be excluded. The presence of carcinoma in situ (which is believed to originate from transformed gonocytes) was detected in 8.7% of biopsies. The incidence...

  7. The value of touch imprint cytology of prostate core needle biopsy ...

    African Journals Online (AJOL)

    S. Hussein

    2015-11-10

    Nov 10, 2015 ... Abstract. Objectives: Touch imprint cytology (TIC) is a reliable, cost-effective technique for the diagnosis of cancer. The aim of this study was to determine the diagnostic value and accuracy of TIC of prostate core needle biopsy (CNB) specimens in predicting the final histology in patients with suspected ...

  8. The value of touch imprint cytology of prostate core needle biopsy ...

    African Journals Online (AJOL)

    Objectives: Touch imprint cytology (TIC) is a reliable, cost-effective technique for the diagnosis of cancer. The aim of this study was to determine the diagnostic value and accuracy of TIC of prostate core needle biopsy (CNB) specimens in predicting the final histology in patients with suspected prostate cancer. Subjects and ...

  9. Does prostate-specific antigen density alter decision making on biopsy?

    NARCIS (Netherlands)

    Vleeming, R.; de Craen, A. J.; de Reijke, T. M.; van Andel, G.; Kurth, K. H.

    1996-01-01

    The ability of prostate-specific antigen density (PSAD) to predict prostate cancer in biopsy specimens is evaluated in patients with benign digital rectal examination (DRE) and prostate-specific antigen (PSA) between 4.0 and 10.0 ng/ml. 144 referred patients with a benign DRE and PSA > 4.0 ng/ml

  10. Application of subsize specimens in nuclear plant life extension

    International Nuclear Information System (INIS)

    Rosinski, S.T.; Kumar, A.S.; Cannon, N.S.; Hamilton, M.L.

    1993-01-01

    The US Department of Energy is sponsoring a research effort through Sandia National Laboratories and the University of Missouri-Rolla to test a correlation for the upper shelf energy (USE) values obtained from the impact testing of subsize Charpy V-notch specimens to those obtained from the testing of full-size samples. The program involves the impact testing of unirradiated and irradiated full-, half-, and third-size Charpy V-notch specimens. To verify the applicability of the correlation on LWR materials, unirradiated and irradiated full-, half-, and third-size Charpy V-notch specimens of a commercial pressure vessel steel (ASTM A533 Grade B) will be tested. The correlation methodology is based on the partitioning of the USE into crack initiation and crack propagation energies. To accomplish this partition, both precracked and notched-only specimens will be used. Whereas the USE of notched-only specimens is the sum of both crack initiation and crack propagation energies, the USE of precracked specimens reflects only the crack propagation component. The difference in the USE of the two types of specimens represents a measure of the crack initiation energy. Normalizing the values of the crack initiation energy to the fracture volume of the sample produces similar values for the full-, half-, and third-size specimens. In addition, the ratios of the USE and the crack propagation energy are also in agreement for full-, half-, and third-size specimens. These two observations will be used to predict the USE of full-size specimens based on subsize USE data. This paper provides details of the program and presents results obtained from the application of the developed correlation methodology to the impact testing of the unirradiated full-, half-, and third-size A533 Grade B Charpy V-notch specimens

  11. The role of procurement biopsies in acceptance decisions for kidneys retrieved for transplant.

    Science.gov (United States)

    Kasiske, Bertram L; Stewart, Darren E; Bista, Bipin R; Salkowski, Nicholas; Snyder, Jon J; Israni, Ajay K; Crary, Gretchen S; Rosendale, John D; Matas, Arthur J; Delmonico, Francis L

    2014-03-01

    There is a shortage of kidneys for transplant, and many patients on the deceased donor kidney transplant waiting list would likely benefit from kidneys that are currently being discarded. In the United States, the most common reason given for discarding kidneys retrieved for transplant is procurement biopsy results. This study aimed to compare biopsy results from discarded kidneys with discard attributed to biopsy findings, with biopsy results from comparable kidneys that were successfully transplanted. In this retrospective, observational, case-control study, biopsy reports were examined from 83 kidneys discarded in 2010 due to biopsy findings (cases), 83 contralateral transplanted kidneys from the same donor (contralateral controls), and 83 deceased donors randomly matched to cases by donor risk profile (randomly matched controls). A second procurement biopsy was obtained in 64 of 332 kidneys (19.3%). The quality of biopsy reports was low, with amounts of tubular atrophy, interstitial inflammation, arteriolar hyalinosis, and acute tubular necrosis often not indicated; 69% were wedge biopsies and 94% used frozen tissue. The correlation between first and second procurement biopsies was poor; only 25% of the variability (R(2)) in glomerulosclerosis was explained by biopsies being from the same kidney. The percentages of glomerulosclerosis overlapped substantially between cases, contralateral controls, and randomly matched controls: 17.1%±15.3%, 9.0%±6.6%, and 5.0%±5.9%, respectively. Of all biopsy findings, only glomerulosclerosis>20% was independently correlated with discard (cases versus contralateral controls; odds ratio, 15.09; 95% confidence interval, 2.47 to 92.41; P=0.003), suggesting that only this biopsy result was used in acceptance decisions. One-year graft survival was 79.5% and 90.7% in contralateral and randomly matched controls, respectively, versus 91.6% among all deceased donor transplants in the Scientific Registry of Transplant Recipients

  12. Computed tomography-guided percutaneous biopsy of pancreatic masses using pneumodissection; Biopsia percutanea de massas pancreaticas guiada por tomografia computadorizada com pneumodisseccao

    Energy Technology Data Exchange (ETDEWEB)

    Tyng, Chiang Jeng; Bitencourt, Almir Galvao Vieira; Almeida, Maria Fernanda Arruda; Barbosa, Paula Nicole Vieira; Martins, Eduardo Bruno Lobato; Junior, Joao Paulo Kawaoka Matushita; Chojniak, Rubens, E-mail: chiangjengtyng@gmail.com [Hospital A.C. Camargo, Sao Paulo, SP (Brazil). Dept. de Imagem; Coimbra, Felipe Jose Fernandez [Hospital A.C. Camargo, Sao Paulo, SP (Brazil). Dept. de Cirurgia Abdominal

    2013-05-15

    Objective: to describe the technique of computed tomography-guided percutaneous biopsy of pancreatic tumors with pneumodissection. Materials and methods: in the period from June 2011 to May 2012, seven computed tomography guided percutaneous biopsies of pancreatic tumors utilizing pneumodissection were performed in the authors' institution. All the procedures were performed with an automatic biopsy gun and coaxial system with Tru-core needles. The biopsy specimens were histologically assessed. Results: in all the cases the pancreatic mass could not be directly approached by computed tomography without passing through major organs and structures. The injection of air allowed the displacement of adjacent structures and creation of a safe coaxial needle pathway toward the lesion. Biopsy was successfully performed in all the cases, yielding appropriate specimens for pathological analysis. Conclusion: Pneumodissection is a safe, inexpensive and technically easy approach to perform percutaneous biopsy in selected cases where direct access to the pancreatic tumor is not feasible. (author)

  13. Multimodal nonlinear microscopy of biopsy specimen: towards intraoperative diagnostics (Conference Presentation)

    Science.gov (United States)

    Schmitt, Michael; Heuke, Sandro; Meyer, Tobias; Chernavskaia, Olga; Bocklitz, Thomas W.; Popp, Juergen

    2016-03-01

    The realization of label-free molecule specific imaging of morphology and chemical composition of tissue at subcellular spatial resolution in real time is crucial for many envisioned applications in medicine, e.g., precise surgical guidance and non-invasive histopathologic examination of tissue. Thus, new approaches for a fast and reliable in vivo and near in vivo (ex corpore in vivo) tissue characterization to supplement routine pathological diagnostics is needed. Spectroscopic imaging approaches are particularly important since they have the potential to provide a pathologist with adequate support in the form of clinically-relevant information under both ex vivo and in vivo conditions. In this contribution it is demonstrated, that multimodal nonlinear microscopy combining coherent anti-Stokes Raman scattering (CARS), two photon excited fluorescence (TPEF) and second harmonic generation (SHG) enables the detection of characteristic structures and the accompanying molecular changes of widespread diseases, particularly of cancer and atherosclerosis. The detailed images enable an objective evaluation of the tissue samples for an early diagnosis of the disease status. Increasing the spectral resolution and analyzing CARS images at multiple Raman resonances improves the chemical specificity. To facilitate handling and interpretation of the image data characteristic properties can be automatically extracted by advanced image processing algorithms, e.g., for tissue classification. Overall, the presented examples show the great potential of multimodal imaging to augment standard intraoperative clinical assessment with functional multimodal CARS/SHG/TPEF images to highlight functional activity and tumor boundaries. It ensures fast, label-free and non-invasive intraoperative tissue classification paving the way towards in vivo optical pathology.

  14. A synoptic reporting system for bone marrow aspiration and core biopsy specimens.

    Science.gov (United States)

    Murari, Manjula; Pandey, Rakesh

    2006-12-01

    Advances in information technology have made electronic systems productive tools for pathology report generation. Structured data formats are recommended for better understanding of pathology reports by clinicians and for retrieval of pathology reports. Suitable formats need to be developed to include structured data elements for report generation in electronic systems. To conform to the requirement of protocol-based reporting and to provide uniform and standardized data entry and retrieval, we developed a synoptic reporting system for generation of bone marrow cytology and histology reports for incorporation into our hospital information system. A combination of macro text, short preformatted templates of tabular data entry sheets, and canned files was developed using a text editor enabling protocol-based input. The system is flexible and has facility for appending free text entry. It also incorporates SNOMED coding and codes for teaching, research, and internal auditing. This synoptic reporting system is easy to use and adaptable. Features and advantages include pick-up text with defined choices, flexibility for appending free text, facility for data entry for protocol-based reports for research use, standardized and uniform format of reporting, comparable follow-up reports, minimized typographical and transcription errors, and saving on reporting time, thus helping shorten the turnaround time. Simple structured pathology report templates are a powerful means for supporting uniformity in reporting as well as subsequent data viewing and extraction, particularly suitable to computerized reporting.

  15. Molecular Detection of Helicobacter pylori ‎Infection in Gastric Biopsy Specimens by PCR

    Directory of Open Access Journals (Sweden)

    Haider Ali AlNaji‎

    2017-12-01

    Full Text Available Infection with Helicobacter pylori is associated with the development of different gastric disorders. Clinical outcome of H. pylori infection related to virulence factors that encoded by genes of this bacteria that can be used in a molecular detection such as the housekeeping genes; ureA and ureC. 16S rRNA is also used in bacterial diagnosis. Seventy-five patients with dyspeptic symptoms sent to esophago- gastroduodenal scope (OGD unit at Merjan Hospital in Babylon Province.  They were diagnosed by specialist physicians and selected in the current study and were classified 43 patients had gastritis, 23 patients had peptic ulcer disease(PUD, 3 had growth like mass non cancer and 6 were normal as negative control.      The results of multiplex PCR and monoplex PCR revealed that a total of 49 (65.3% cases were found positive for H. pylori by 16S rRNA and ureA, whereas ureC primer is less sensitive for bacterial detection

  16. Comparison of Quantitative Microbiology and Histopathology in Divided Burn-Wound Biopsy Specimens

    Science.gov (United States)

    1987-01-01

    control of microbial growth is a temperature. critical facto. in instituting further steps to prevent or treat Pearson’s correlation coefficient and...bacterial counts with the Rhizopus species 1 clinical condition of the patient. However, although not specifically None* 3 stated in the report, I

  17. Assessment of in vitro drug resistance of human breast cancer cells subcultured from biopsy specimens

    Czech Academy of Sciences Publication Activity Database

    Krásná, Luboslava; Netíková, I.; Chaloupková, Alena; Taišlová, Eva; Zimovjanová, M.; Veselý, Pavel; Daneš, J.; Petruželka, L.; Matoušková, Eva

    2003-01-01

    Roč. 23, 3B (2003), s. 2593-2600 ISSN 0250-7005 R&D Projects: GA MZd NC6734 Institutional research plan: CEZ:AV0Z5052915 Keywords : Breast cancer * 3T3 feeder-layer culture technique * MTT test Subject RIV: EA - Cell Biology Impact factor: 1.347, year: 2003

  18. Impact of Consensus Conference Review on Diagnostic Disagreements in the Evaluation of Cervical Biopsy Specimens.

    Science.gov (United States)

    Layfield, Lester J; Hammer, Richard D; Frazier, Shellaine R; Esebua, Magda; Bivin, William W; Laziuk, Katsiaryna; Nguyen, Van T; Johannesen, Eric; Schmidt, Robert L

    2017-05-01

    To determine the impact of consensus conferences on the frequency of discrepant cases in a surgical pathology practice. The percentage of discrepancies in cases reviewed at a weekly consensus conference was calculated for the first and last months of a 13-month period. Both interrater agreement and agreement with the consensus diagnoses were assessed. A total of 309 diagnoses were performed for the first month and 518 for the last month. Both absolute and chance-corrected agreement were calculated for each period. Absolute agreement rate increased from 91.2% in the first month to 98.2% in the final month. Chance-corrected agreement increased from 0.80 in the first month to 0.97 in the final month. The consensus conference technique appears to be a useful method to reduce intradepartmental diagnostic discrepancies. Both absolute and chance-corrected agreement are improved by using consensus conferences. © American Society for Clinical Pathology, 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  19. Role of microscopic examination of stool specimens in the diagnosis ...

    African Journals Online (AJOL)

    stain of the stool in diagnosis of campylobacter infection, using culture as the gold standard. A total of 226 stool specimens were obtained from children with acute diarrhoea, attending Mulago Hospital in Kampala, Uganda. Stool smears were ...

  20. 20 CFR 718.106 - Autopsy; biopsy.

    Science.gov (United States)

    2010-04-01

    ... 20 Employees' Benefits 3 2010-04-01 2010-04-01 false Autopsy; biopsy. 718.106 Section 718.106... PNEUMOCONIOSIS Criteria for the Development of Medical Evidence § 718.106 Autopsy; biopsy. (a) A report of an autopsy or biopsy submitted in connection with a claim shall include a detailed gross macroscopic and...

  1. Breast magnetic resonance imaging guided biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Yun, Bo La; Kim, Sun Mi; Jang, Mi Jung [Dept. of Radiology, Seoul National University Bundang Hospital, Seongnam (Korea, Republic of); Cho, Nariya; Moon, Woo Kyung [Dept. of Radiology, Seoul National University Hospital, Seoul (Korea, Republic of); Kim, Hak Hee [Dept. of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of)

    2016-06-15

    Despite the high sensitivity of breast magnetic resonance imaging (MRI), pathologic confirmation by biopsy is essential because of limited specificity. MRI-guided biopsy is required in patients with lesions only seen on MRI. We review preprocedural considerations and the technique of MRI-guided biopsy, challenging situations and trouble-shooting, and correlation of radiologic and pathologic findings.

  2. Freehand biopsy guided by electromagnetic needle tracking

    DEFF Research Database (Denmark)

    Ewertsen, C; Nielsen, Marie Kristina Rue; Nielsen, M Bachmann

    2011-01-01

    To evaluate the overall accuracy and time spent on biopsy guided by electromagnetic needle tracking in a phantom compared with the standard technique of US-guided biopsy with an attached steering device. Furthermore, to evaluate off-plane biopsy guided by needle tracking....

  3. The value of percutaneous trephine biopsy in the diagnosis of ...

    African Journals Online (AJOL)

    1991-01-05

    Jan 5, 1991 ... CERVICAL o. 40. ----..-.--.-.----.-.-. -- --.--. 50 -. 30. 10. 20. Fig. 1. Distribution of vertebrae. The results obtained in 55 adult patients with sinister lesions of vertebral bodies, who were sUbjected to percutaneous trephine biopsy, are presented. A positive diagnosis was made on histopathological examination of ...

  4. The localisation of treponemes and characterisation of the inflammatory infiltrate in skin biopsies from patients with primary or secondary syphilis, or early infectious yaws

    NARCIS (Netherlands)

    Engelkens, H. J.; ten Kate, F. J.; Judanarso, J.; Vuzevski, V. D.; van Lier, J. B.; Godschalk, J. C.; van der Sluis, J. J.; Stolz, E.

    1993-01-01

    To study the localisation of treponemes and to analyse the inflammatory infiltrate in biopsy specimens from patients with primary or secondary syphilis, or early infectious yaws. Skin biopsies originating from human lesions of primary (29x) or secondary (15x) syphilis (Rotterdam), or early yaws

  5. Percutaneous transluminal forceps biopsy in patients suspected of having malignant biliary obstruction: factors influencing the outcomes of 271 patients

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jung Gu; Jung, Gyoo-Sik; Yun, Jong Hyouk [Kosin University College of Medicine, Department of Radiology, Seo-gu, Busan (Korea, Republic of); Yun, Byung Chul; Lee, Sang Uk; Han, Byung Hoon [Kosin University College of Medicine, Department of Internal Medicine, Busan (Korea, Republic of); Ko, Ji Ho [Busan Medical Center, Department of Radiology, Busan (Korea, Republic of)

    2017-10-15

    To evaluate predictive factors for false-negative diagnosis of percutaneous forceps biopsies in patients suspected of having a malignant biliary obstruction Two hundred seventy one consecutive patients with obstructive jaundice underwent percutaneous forceps biopsy. In each patient, three to five specimens (mean, 3.5 specimens) were collected from the lesion. The final diagnosis for each patient was confirmed with pathologic findings at surgery, additional histocytologic data, or clinical and radiologic follow-up. Univariate and multivariate logistic regression analysis was used to identify risk factors associated with false-negative diagnosis. One hundred ninety four of 271 biopsies resulted in correct diagnoses of malignancy, while 20 biopsy diagnoses were proved to be true-negative. There were 57 false-negative diagnoses and no false-positive diagnoses. The diagnostic performance of transluminal forceps biopsy in malignant biliary obstructions was as follows: sensitivity, 77.2%; specificity, 100%; and accuracy, 78.9%; positive predictive value, 100%, negative predictive value; 25.9%. Periampullary segment of common bile duct, intrahepatic bile duct and metastatic disease were the significant risk factors of false-negative diagnosis. Percutaneous forceps biopsy provides relatively high accuracy in the diagnosis of malignant biliary obstructions. The predictive factors of false-negative biopsy were determined to be biopsy site and origin of primary tumour. (orig.)

  6. Single-Pass Percutaneous Liver Biopsy for Diffuse Liver Disease Using an Automated Device: Experience in 154 Procedures

    International Nuclear Information System (INIS)

    Rivera-Sanfeliz, Gerant; Kinney, Thomas B.; Rose, Steven C.; Agha, Ayad K.M.; Valji, Karim; Miller, Franklin J.; Roberts, Anne C.

    2005-01-01

    Purpose: To describe our experience with ultrasound (US)-guided percutaneous liver biopsies using the INRAD 18G Express core needle biopsy system.Methods: One hundred and fifty-four consecutive percutaneous core liver biopsy procedures were performed in 153 men in a single institution over 37 months. The medical charts, pathology reports, and radiology files were retrospectively reviewed. The number of needle passes, type of guidance, change in hematocrit level, and adequacy of specimens for histologic analysis were evaluated.Results: All biopsies were performed for histologic staging of chronic liver diseases. The majority of patients had hepatitis C (134/153, 90.2%). All patients were discharged to home after 4 hr of postprocedural observation. In 145 of 154 (94%) biopsies, a single needle pass was sufficient for diagnosis. US guidance was utilized in all but one of the procedures (153/154, 99.4%). The mean hematocrit decrease was 1.2% (44.1-42.9%). Pain requiring narcotic analgesia, the most frequent complication, occurred in 28 of 154 procedures (18.2%). No major complications occurred. The specimens were diagnostic in 152 of 154 procedures (98.7%).Conclusions: Single-pass percutaneous US-guided liver biopsy with the INRAD 18G Express core needle biopsy system is safe and provides definitive pathologic diagnosis of chronic liver disease. It can be performed on an outpatient basis. Routine post-biopsy monitoring of hematocrit level in stable, asymptomatic patients is probably not warranted

  7. Evolution of prostate biopsy techniques. Looking back on a meaningful journey.

    Science.gov (United States)

    Sivaraman, A; Sanchez-Salas, R; Castro-Marin, M; Barret, E; Guillot-Tantay, C; Prapotnich, D; Cathelineau, X

    2016-10-01

    The technique of prostate biopsy has evolved a long way since its inception to being a safe diagnostic procedure. The principles of the biopsy technique continue to improvise with the knowledge about prostate cancer and availability of newer treatment options like active surveillance and focal therapy. Currently, we depend on accurate cancer information from the biopsy more than ever for deciding the ideal treatment option. The aim of this review is to present the major milestones in prostate biopsy technique evolutions and its impact on the prostate cancer management. We performed a detailed non-systematic literature review to present the historical facts on the transformations in prostate biopsy techniques and also the direction of present research to improve accurate cancer detection. There is a clear change in trend in biopsy technique before and after the introduction of transrectal ultrasound and prostate specific antigen. In the earlier era, the biopsies were aimed at palpable nodules and obtaining adequate prostatic tissue for diagnosis while the later era has moved towards detection of non-palpable and early prostate cancer. Recently, there is an increasing trend towards image guided targeted biopsies to extract maximum cancer information from minimum biopsy cores. Prostate biopsy techniques have seen major changes since its inception and have a major impact on prostate cancer management. There is a great potential for research which can further support the newer treatment options like focal therapy. Copyright © 2016 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  8. Correlation of kidney biopsy findings and clinical manifestations of primary focal and segmental glomerulosclerosis.

    Science.gov (United States)

    Taheri, Diana; Chehrei, Ali; Samanianpour, Pargol; Hassanzadeh, Amar; Sadrarhami, Shohreh; Seyrafian, Shiva

    2009-05-01

    To evaluate the correlation of clinical, laboratory, and pathological features at pre-sentation of focal segmental sclerosis (FSGS), we reviewed in a cross sectional study the pathological findings of kidney biopsies in 64 cases of primary FSGS, and correlated them with the clinical and laboratory data obtained at the time of the biopsies. The data included blood pressure, glomerular filtration rate (GFR), serum albumin, and the level of proteinuria. The mean level of serum creatinine was significantly higher in the biopsies' findings of synechiae (adhesions) in the Bowman's capsule, interstitial fibrosis, and global scars (PBowman's capsule in their biopsies.

  9. Prospective Study for Comparison of Endoscopic Ultrasound-Guided Tissue Acquisition Using 25- and 22-Gauge Core Biopsy Needles in Solid Pancreatic Masses.

    Science.gov (United States)

    Park, Se Woo; Chung, Moon Jae; Lee, Sang Hoon; Lee, Hee Seung; Lee, Hyun Jik; Park, Jeong Yup; Park, Seung Woo; Song, Si Young; Kim, Hoguen; Chung, Jae Bock; Bang, Seungmin

    2016-01-01

    Although thicker needles theoretically allow more tissue to be collected, their decreased flexibility can cause mechanical damage to the endoscope, technical failure, and sample blood contamination. The effects of needle gauge on diagnostic outcomes of endoscopic ultrasound-guided fine-needle biopsy (EUS-FNB) of pancreatic mass lesions remain unknown. This study compared procurement rates of histologic cores obtained from EUS-FNB of pancreatic masses using 25- and 22-gauge core biopsy needles. From March 2014 to July 2014, 66 patients with solid pancreatic mass underwent EUS-FNB with both 25- and 22-gauge core biopsy needles. Among them, 10 patients were excluded and thus 56 patients were eligible for the analyses. Needle sequences were randomly assigned, and two passes were made with each needle, consisting of 10 uniform to-and-fro movements on each pass with 10 mL syringe suction. A pathologist blinded to needle sequence evaluated specimens for the presence of histologic core. The mean patient age was 65.8 ± 9.5 years (range, 44-89 years); 35 patients (62.5%) were men. The mean pancreatic mass size was 35.3 ± 17.1 mm (range 14-122.3 mm). Twenty-eight patients (50%) had tumors at the pancreas head or uncinate process. There were no significant differences in procurement rates of histologic cores between 25-gauge (49/56, 87.5%) and 22-gauge (46/56, 82.1%, P = 0.581) needles or diagnostic accuracy using only histologic cores (98% and 95%). There were no technical failures or procedure-related adverse events. The 25-gauge core biopsy needle could offer acceptable and comparable outcomes regarding diagnostic performance including histologic core procurement rates compared to the 22-gauge core biopsy needle, although the differences were not statistically significant. ClinicalTrials.gov NCT01795066.

  10. Diagnostic Accuracy of Multiparametric Magnetic Resonance Imaging and Fusion Guided Targeted Biopsy Evaluated by Transperineal Template Saturation Prostate Biopsy for the Detection and Characterization of Prostate Cancer.

    Science.gov (United States)

    Mortezavi, Ashkan; Märzendorfer, Olivia; Donati, Olivio F; Rizzi, Gianluca; Rupp, Niels J; Wettstein, Marian S; Gross, Oliver; Sulser, Tullio; Hermanns, Thomas; Eberli, Daniel

    2018-02-21

    We evaluated the diagnostic accuracy of multiparametric magnetic resonance imaging and multiparametric magnetic resonance imaging/transrectal ultrasound fusion guided targeted biopsy against that of transperineal template saturation prostate biopsy to detect prostate cancer. We retrospectively analyzed the records of 415 men who consecutively presented for prostate biopsy between November 2014 and September 2016 at our tertiary care center. Multiparametric magnetic resonance imaging was performed using a 3 Tesla device without an endorectal coil, followed by transperineal template saturation prostate biopsy with the BiopSee® fusion system. Additional fusion guided targeted biopsy was done in men with a suspicious lesion on multiparametric magnetic resonance imaging, defined as Likert score 3 to 5. Any Gleason pattern 4 was defined as clinically significant prostate cancer. The detection rates of multiparametric magnetic resonance imaging and fusion guided targeted biopsy were compared with the detection rate of transperineal template saturation prostate biopsy using the McNemar test. We obtained a median of 40 (range 30 to 55) and 3 (range 2 to 4) transperineal template saturation prostate biopsy and fusion guided targeted biopsy cores, respectively. Of the 124 patients (29.9%) without a suspicious lesion on multiparametric magnetic resonance imaging 32 (25.8%) were found to have clinically significant prostate cancer on transperineal template saturation prostate biopsy. Of the 291 patients (70.1%) with a Likert score of 3 to 5 clinically significant prostate cancer was detected in 129 (44.3%) by multiparametric magnetic resonance imaging fusion guided targeted biopsy, in 176 (60.5%) by transperineal template saturation prostate biopsy and in 187 (64.3%) by the combined approach. Overall 58 cases (19.9%) of clinically significant prostate cancer would have been missed if fusion guided targeted biopsy had been performed exclusively. The sensitivity of

  11. THE PROGNOSTIC AND DIAGNOSTIC VALUE OF REPEATED TRANSRECTAL PROSTATE SATURATION BIOPSY

    Directory of Open Access Journals (Sweden)

    M. A. Kurdzhiev

    2014-08-01

    Full Text Available Objective: to determine the rate of prostate cancer (PC development after repeated transrectal saturation prostate biopsy (RTRSPB, to study the characteristics of diagnosed tumors, and to estimate their clinical significance from the data of radical retropubic prostatectomy (RRP.Materials and methods. The results of RTRSPB were analyzed in 226 patients with a later evaluation of a tumor from the results of RRP. All the patients underwent at least 2 prostate biopsies (mean 2.4. The average number of biopsy cores was 26.7 (range 24—30. The average value of total prostate-specific antigen before saturation biopsy was 7.5 (range 7.5 to 28.6 ng/ml. The mean age of patients was 62 years (range 53 to 70.  Results. PC was diagnosed in 14.6% of cases (33/226. An isolated lesion of the prostatic transition zone was in 12.1% of cases. If this zone had been excluded from the biopsy scheme, the detection rate of PC during saturation biopsy should be reduced by 13.8%. Better PC detectability during repeated saturation biopsy generally occurred due to the localized forms of the disease (93.3%. The agreement of Gleason tumor grading in the biopsy and prostatectomy specimens was noted in 66.7% of cases.Conclusion. Saturation biopsy allows prediction of a pathological stage of PC, Gleason grade of a tumor and its site localization with a greater probability. Most tumors detectable by saturation biopsy were clinically significant, which makes it possible to recommend RTRSPB to some cohort of high PC-risk patients 

  12. Novel computer-aided diagnosis of mesothelioma using nuclear structure of mesothelial cells in effusion cytology specimens

    Science.gov (United States)

    Tosun, Akif Burak; Yergiyev, Oleksandr; Kolouri, Soheil; Silverman, Jan F.; Rohde, Gustavo K.

    2014-03-01

    diagnostic standard is a pleural biopsy with subsequent histologic examination of the tissue demonstrating invasion by the tumor. The diagnostic tissue is obtained through thoracoscopy or open thoracotomy, both being highly invasive procedures. Thoracocenthesis, or removal of effusion fluid from the pleural space, is a far less invasive procedure that can provide material for cytological examination. However, it is insufficient to definitively confirm or exclude the diagnosis of malignant mesothelioma, since tissue invasion cannot be determined. In this study, we present a computerized method to detect and classify malignant mesothelioma based on the nuclear chromatin distribution from digital images of mesothelial cells in effusion cytology specimens. Our method aims at determining whether a set of nuclei belonging to a patient, obtained from effusion fluid images using image segmentation, is benign or malignant, and has a potential to eliminate the need for tissue biopsy. This method is performed by quantifying chromatin morphology of cells using the optimal transportation (Kantorovich-Wasserstein) metric in combination with the modified Fisher discriminant analysis, a k-nearest neighborhood classification, and a simple voting strategy. Our results show that we can classify the data of 10 different human cases with 100% accuracy after blind cross validation. We conclude that nuclear structure alone contains enough information to classify the malignant mesothelioma. We also conclude that the distribution of chromatin seems to be a discriminating feature between nuclei of benign and malignant mesothelioma cells.

  13. Sentinel lymph node biopsy in patients with a needle core biopsy diagnosis of ductal carcinoma in situ: is it justified?

    LENUS (Irish Health Repository)

    Doyle, B

    2012-02-01

    BACKGROUND: The incidence of ductal carcinoma in situ (DCIS) has increased markedly with the introduction of population-based mammographic screening. DCIS is usually diagnosed non-operatively. Although sentinel lymph node biopsy (SNB) has become the standard of care for patients with invasive breast carcinoma, its use in patients with DCIS is controversial. AIM: To examine the justification for offering SNB at the time of primary surgery to patients with a needle core biopsy (NCB) diagnosis of DCIS. METHODS: A retrospective analysis was performed of 145 patients with an NCB diagnosis of DCIS who had SNB performed at the time of primary surgery. The study focused on rates of SNB positivity and underestimation of invasive carcinoma by NCB, and sought to identify factors that might predict the presence of invasive carcinoma in the excision specimen. RESULTS: 7\\/145 patients (4.8%) had a positive sentinel lymph node, four macrometastases and three micrometastases. 6\\/7 patients had invasive carcinoma in the final excision specimen. 55\\/145 patients (37.9%) with an NCB diagnosis of DCIS had invasive carcinoma in the excision specimen. The median invasive tumour size was 6 mm. A radiological mass and areas of invasion <1 mm, amounting to "at least microinvasion" on NCB were predictive of invasive carcinoma in the excision specimen. CONCLUSIONS: SNB positivity in pure DCIS is rare. In view of the high rate of underestimation of invasive carcinoma in patients with an NCB diagnosis of DCIS in this study, SNB appears justified in this group of patients.

  14. Long-term cultures of testicular biopsies from boys with cryptorchidism

    DEFF Research Database (Denmark)

    Larsen, Hans-Peter Ejler; Thorup, Jørgen; Skovgaard, Lene Theil

    2002-01-01

    BACKGROUND: A long-term culture system of testicular biopsies from boys with undescended testes was established to evaluate the effect of gonadotrophins on germ cell survival and growth. METHODS: Biopsies from 25 boys with cryptorchidism, aged 1.1-9.9 years, were obtained at the time of surgery...

  15. Automated tru-cut imaging-guided core needle biopsy of canine ...

    African Journals Online (AJOL)

    The purpose of this study was to evaluate the diagnostic value of imaging-guided core needle biopsy for canine orbital mass diagnosis. A second excisional biopsy obtained during surgery or necropsy was used as the reference standard. A prospective feasibility study was conducted in 23 canine orbital masses at a single ...

  16. Sonographically guided fine-needle biopsy of thyroid nodules: the effects of nodule characteristics, sampling technique, and needle size on the adequacy of cytological material

    International Nuclear Information System (INIS)

    Degirmenci, B.; Haktanir, A.; Albayrak, R.; Acar, M.; Sahin, D.A.; Sahin, O.; Yucel, A.; Caliskan, G.

    2007-01-01

    Aim: To evaluate the effects of sonographic characteristics of thyroid nodules, the diameter of needle used for sampling, and sampling technique on obtaining sufficient cytological material (SCM). Materials and methods: We performed sonography-guided fine-needle biopsy (FNB) in 232 solid thyroid nodules. Size-, echogenicity, vascularity, and localization of all nodules were evaluated by Doppler sonography before the biopsy. Needles of size 20, 22, and 24 G were used for biopsy. The biopsy specimen was acquired using two different methods after localisation. In first method, the needle tip was advanced into the nodule in various positions using a to-and-fro motion whilst in the nodule, along with concurrent aspiration. In the second method, the needle was advanced vigorously using a to-and-fro motion within the nodule whilst being rotated on its axis (capillary-action technique). Results: The mean nodule size was 2.1 ± 1.3 cm (range 0.4-7.2 cm). SCM was acquired from 154 (66.4%) nodules by sonography-guided FNB. In 78 (33.6%) nodules, SCM could not be collected. There was no significant difference between nodules with different echogenicity and vascularity for SCM. Regarding the needle size, the lowest rate of SCM was obtained using 20 G needles (56.6%) and the highest rate of adequate material was obtained using 24 G needles (82.5%; p = 0.001). The SCM rate was 76.9% with the capillary-action technique versus 49.4% with the aspiration technique (p < 0.001). Conclusion: Selecting finer needles (24-25 G) for sonography-guided FNB of thyroid nodules and using the capillary-action technique decreased the rate of inadequate material in cytological examination

  17. Role of pleural biopsy in etiological diagnosis of pleural effusion

    Directory of Open Access Journals (Sweden)

    Pandit Sudipta

    2010-01-01

    Full Text Available Background: Pleural effusion remains the most common manifestation of pleural pathology. Sometimes it is difficult to differentiate between tubercular and malignant pleural effusion in spite of routine biochemical and cytological examination of pleural fluid. Aims: This study aims to evaluate the role of pleural biopsy to determine the etiology of pleural effusion and to correlate it with the biochemical and cytological parameters of pleural fluid. Settings and Design: Seventy two consecutive patients of pleural effusion were selected from the out patient and indoor department of a tertiary hospital of Kolkata. It was a prospective and observational study conducted over a period of one year. Materials and Methods: Biochemical, cytological and microbiological evaluation of pleural fluid was done in all cases. Those with exudative pleural effusions underwent pleural biopsy by Abram′s needle. Subsequently, the etiology of effusion was determined. Results: Malignancy was the most common etiology, followed by tuberculosis. Pleural biopsy was done in 72 patients. Pleural tissue was obtained in 62 cases. Malignancy was diagnosed in 24, tuberculosis in 20 and non-specific inflammation in 18, on histopathological examination. Out of 20 histological proven tuberculosis cases adenosine de-aminase (ADA was more than 70 u/l in 11 cases. Conclusions: In our study, malignancy is more common than tuberculosis, particularly in elderly. When thoracoscope is not available, pleural fluid cytology and pleural biopsy can give definite diagnosis. Pleural fluid ADA ≥ 70 u/l is almost diagnostic of tuberculosis, where pleural biopsy is not recommended.

  18. Tissue Biopsies in Diabetes Research

    DEFF Research Database (Denmark)

    Højlund, Kurt; Gaster, Michael; Beck-Nielsen, Henning

    2007-01-01

    Type 2 diabetes is characterized by insulin resistance in major metabolic tissues such as skeletal muscle, liver and fat cells, and failure of the pancreatic ß-cells to compensate for this abnormality (1,2). Skeletal muscle is the major site of glucose disposal in response to insulin, and insulin....... Together with morphological studies, measurement of energy stores and metabolites, enzyme activity and phosphorylation, gene and protein expression in skeletal muscle biopsies have revealed a variety of cellular abnormalities in patients with type 2 diabetes and prediabetes. The possibility to establish...

  19. Tissue Biopsies in Diabetes Research

    DEFF Research Database (Denmark)

    Højlund, Kurt; Gaster, Michael; Beck-Nielsen, Henning

    2007-01-01

    Type 2 diabetes is characterized by insulin resistance in major metabolic tissues such as skeletal muscle, liver and fat cells, and failure of the pancreatic ß-cells to compensate for this abnormality (1,2). Skeletal muscle is the major site of glucose disposal in response to insulin, and insulin...... description of the technique of percutaneous needle biopsy of skeletal muscle and the establishment of human muscle cell cultures together with a discussion of advantages and limitations of the methods in diabetes research...

  20. Fifteen years of kidney biopsies in children: A single center in Egypt

    Directory of Open Access Journals (Sweden)

    Ashraf Bakr

    2014-01-01

    Full Text Available This study retrospectively investigates the indications and results of renal biopsy in children to determine the patterns of childhood kidney disease in a single tertiary children′s hospital in Egypt. We included all the patients who underwent ultrasound-guided renal biopsy from 1998 to 2012. All the kidney biopsies were studied under light microscopy, while immunofluorescence and electron microscopy were performed when indicated. A total of 1246 renal biopsies were performed over 15 years, on 1096 patients. The mean age of the patients at the time of biopsy was 9.2 ± 3.7 years. The main indication for a biopsy was the steroid-resistant nephrotic syndrome (n = 354, 28.4%, followed by the atypical nephrotic syndrome (n = 250, 20.1%, and renal abnormalities in the systemic diseases (n = 228, 18.3 %. In the 1226 pathologically diagnosed specimens, primary glomerulonephritis was the most common finding (n = 826, 67.4%, followed by secondary glomerulonephritis (n = 238, 19.4%. The most common causes of primary glomerulonephritis were Minimal Change Disease (MCD (n = 267, 21.8%, diffuse proliferative glomerulonephritis (n = 188, 15. 3%, and focal proliferative glomerulonephritis (n = 164, 13.3%. Lupus nephritis (n = 209, 17% was the most common cause of secondary glomerulonephritis. We conclude that the steroid-resistant nephrotic syndrome was the most frequent indication for biopsy and minimal change disease was the most common histopathological finding in our population.

  1. CT guided fine needle aspiration biopsy of biliopancreatic lesions

    International Nuclear Information System (INIS)

    Geng, Jia-Zheng; Qin, Pan-Rui; Hui, Liu-De; Po, Pei-Dong

    1987-01-01

    CT guided percutaneous fine needle aspiration biopsy was performed on 30 patients with pancreatic and periampullary neoplasms, in the Department of Surgery, China-Japan Friendship Hospital, between March 1985 and January 1986. We obtained positive cytodiagnosis from all cases of carcinoma of the pancreatic head (9 cases), body and tail (4 cases), and ampullary carcinomas (5 cases) (100 per cent). In 2 of 3 duodenal carcinomas (66.6 per cent), and 6 of 7 distal common duct carcinomas (86 per cent), a positive cytodiagnosis was also obtained. On the other hand, 2 cases of pancreatitis both gave a negative cytodiagnosis, i.e. no false positives were obtained. Out of the 30 cases who underwent CT guided biopsy, a correct diagnosis was obtained in 28, i.e. a diagnostic accuracy of 93.3 per cent. The cytodiagnosis of the other two cases was either suspicious or false negative. There have been no clinical complications noted. (author)

  2. Infective complications in patients after transrectal ultrasound-guided prostate biopsy and the role of ciprofloxacin resistant Escherichia coli colonization in rectal flora.

    Science.gov (United States)

    Hamarat, Mustafa Bilal; Tarhan, Fatih; Horuz, Rahim; Öcal, Gülfem Akengin; Demirkol, Mehmet Kutlu; Kafkaslı, Alper; Yazıcı, Özgür

    2017-06-01

    other prophylactic agents for a certain period of time in populations with higher rates of resistance to this medical agent. Furthermore, it will be appropriate again to obtain rectal swab specimens for culture tests before biopsy procedure in order to perform targeted prophylaxis according to the culture antibiogram test results. This approach will enable us to evaluate the cost-effectiveness of the procedure in detail.

  3. Diagnostic yield of kidney biopsies performed in a suburban, satellite hospital

    Directory of Open Access Journals (Sweden)

    Che Rosle Draman

    2013-01-01

    Full Text Available Kidney biopsy is indicated to confirm the clinical diagnosis or to evaluate prognosis of a renal problem. It is a reliable and safe procedure, especially with real-time ultrasound guidance. This is a single-center, retrospective review of the biopsies performed in Hospital Tengku Ampuan Afzan, Pahang from 2000 to 2010. The demographic data, clinical parameters, and histological reports were extracted from clinic records and analyzed to determine the diagnostic adequacy of biopsy samples for both lupus and non-lupus patients. A total of 219 biopsies were performed throughout the period and only 74 were included in this review. Their mean age was 22.5 ± 10.5 years. 59.5% of the biopsies were performed on female patients. Malays comprised 79.7% (n = 59 of them, followed by Chinese (18.9%, n=14 and Indian (1.4%, n=1. About one-third of the biopsies(n = 25 were performed on patients with lupus nephritis and two-thirds (n = 49 on non-lupus nephritis patients. At the time of biopsy, their serum creatinine values were normal, serum albumin 28.4 ± 10 g/L and total cholesterol 8.9 ± 4.6 mmol/L (mean ± SD. The urine dipstick was 3+ for both proteinuria and hematuria and daily protein excretion was 3.6 ± 3.2 g. Sixty-seven specimens were considered adequate and only six (8% were inadequate for histological interpretations. The mean number of glomeruli in the biopsy specimens was 16 ± 9.9 (range: 0-47 glomeruli. In non-lupus patients, focal segmental glomerulosclerosis was the commonest histological diagnosis (n = 15, 30.6%, followed by minimal change disease (n = 13, 26.5% and mesangial proliferative glomerulonephritis (n = 7, 14.3%. Membranous nephropathy was diagnosed in four (8.2% and membranoproliferative glomerulonephritis in two (4.1% specimens. Both post-infectious glomerulonephritis and advanced glomerulosclerosis were found in one specimen each. Among the lupus nephritis patients (n = 25, 88% of them were females (P <0.05 and lupus nephritis

  4. Analysis of the liver biopsies: a histopathological study

    International Nuclear Information System (INIS)

    Hanif, G.; Zaman, S.; Hamid, T.

    2001-01-01

    Objective: To evaluate the spectrum of childhood liver diseases. Design: a department based retrospective study. Place and Duration of study: It was carried out at the department of Pathology, Children's Hospital and the Institute of Child Health, Lahore, over a period of two years (October 1998 to October 2000). Subjects and Methods: The histopathological data of total 50 percutaneous needle biopsies, wedge biopsies and partial hepatectomy specimens of both the sexes between 1 month 16 years age were collected and compared with the findings reported from centers in other parts of the county. Results: The commonest cause of hepatomegaly was hepatic inflammatory disorder in 43 cases (29%) followed by biliary atresia in 40 cases (27%). Other causes of hepatomegaly were hepatic neoplasia 11 caes (7.3%), cirrhosis 10 cases (7%), glycogen storage disease 10 cases (7%) and fatty change in 8 cases (5.3%). Conclusion: Hepatic diseases are quite common in paediatric population in Pakistan and percutaneous needle liver biopsy is an important and helpful diagnostic procedure in undiagnosed cases of hepatomegaly. (author)

  5. Single-port retroperitoneal renal biopsy using standard urological instruments

    Directory of Open Access Journals (Sweden)

    Rodrigo Guerra

    2015-02-01

    Full Text Available Objective To describe the surgical technique and initial experience with a single-port retroperitoneal renal biopsy (SPRRB. Materials and Methods Between January and April 2013, five children underwent SPRRB in our hospital. A single 1.5 cm incision was performed under the 12th rib at mid-axillary line, and an 11 mm trocar was inserted. A nephroscope was used to identify the kidney and dissect the perirenal fat. After lower pole exposure, a laparoscopic biopsy forceps was introduced through the nephroscope working channel to collect a renal tissue sample. Results SPRRB was successfully performed in five children. The mean operative time was 32 minutes, and mean estimated blood loss was less than 10 mL. The hospital stay of all patients was two days because they were discharged in the second postoperative day, after remaining at strict bed rest for 24 hours after the procedure. The average number of glomeruli present in the specimen was 31. Conclusion SPRRB is a simple, safe and reliable alternative to open and videolaparoscopic approaches to surgical renal biopsy.

  6. Comparison of Histologic Core Portions Acquired from a Core Biopsy Needle and a Conventional Needle in Solid Mass Lesions: A Prospective Randomized Trial.

    Science.gov (United States)

    Lee, Ban Seok; Cho, Chang-Min; Jung, Min Kyu; Jang, Jung Sik; Bae, Han Ik

    2017-07-15

    The superiority of endoscopic ultrasound-guided fine needle biopsy (EUS-FNB) over EUS-guided fine needle aspiration (EUS-FNA) remains controversial. Given the lack of studies analyzing histologic specimens acquired from EUS-FNB or EUS-FNA, we compared the proportion of the histologic core obtained from both techniques. A total of 58 consecutive patients with solid mass lesions were enrolled and randomly assigned to the EUS-FNA or EUS-FNB groups. The opposite needle was used after the failure of core tissue acquisition using the initial needle with up to three passes. Using computerized analyses of the scanned histologic slide, the overall area and the area of the histologic core portion in specimens obtained by the two techniques were compared. No significant differences were identified between the two groups with respect to demographic and clinical characteristics. Fewer needle passes were required to obtain core specimens in the FNB group (pcore (11.8%±19.5% vs 8.0%±11.1%, p=0.376) or in the diagnostic accuracy (80.6% vs 81.5%, p=0.935) between two groups. The proportion of histologic core and the diagnostic accuracy were comparable between the FNB and FNA groups. However, fewer needle passes were required to establish an accurate diagnosis in EUS-FNB.

  7. Specimen Collection and Submission Manual

    Science.gov (United States)

    2016-06-01

    local, approved medical treatment facility collection procedures. Superficial wounds and abscesses Sterile swab Follow local, approved medical...Tests May Include: West Nile virus (WNV), Eastern equine encephalitis virus, Venezuelan equine encephalitis virus, yellow fever virus, dengue virus... Wound Botulism Acceptable Specimens Required Volume/Comments Toxin Assay (T) or Culture (C) Performed Serum (priority sample type) 5 ml (less

  8. Detection of prostate cancer: comparison of cancer detection rates of sextant and extended ten-core biopsy protocols.

    Science.gov (United States)

    Ojewola, R W; Tijani, K H; Jeje, E A; Anunobi, C C; Ogunjimi, M A; Ezenwa, E V; Ogundiniyi, O S

    2012-09-01

    To compare the cancer detection rates of sextant and ten- core biopsy protocol amongst patients being evaluated for prostate cancer. This is a prospective study involving 125 men with suspicion of prostate cancer. They all had an extended 10-core transrectal digitally-guided prostatic biopsy using Tru-Cut needle. Indications for biopsy were presence of one or more of the following: elevated Prostate Specific Antigen (PSA), abnormal Digital Rectal Examination (DRE) findings and abnormal prostate scan. Sextant biopsies were collected first, followed by four lateral biopsies in all patients. Both groups of specimen were kept and analyzsed separately by the same pathologist. The cancer detection rates of sextant and extended (combination of sextant and lateral) 10-core biopsy protocols were determined and compared. Pearson's Chi square and McNemar tests at two degrees of freedom with level of significance set at 0.05 ( P <0.005) were used to determine the statistical significance. The overall cancer detection rate of 10-core prostate biopsy was 48.8%. Of all positive biopsies, the sextant biopsy protocol detected 52 cancers (85.2%) while the lateral biopsy protocol detected 58 cases (95.1%). Three (3) cancers were detected by the sextant protocol only while the lateral protocol detected nine (9) cancers where sextant technique was negative for malignancy. Ten-core extended protocol showed a statistically significant increase of 14.8% over the traditional sextant. (P=0.046). The overall complication rate of ten-core biopsy was 26.4% and the procedure was well tolerated in most patients. We conclude that a ten-core prostate biopsy protocol significantly improves cancer detection and should be considered as the optimum biopsy protocol.

  9. Analysis of 62 cases with stereotaxic breast biopsy with a prone table system: emphasis on lesions with microcalcificatios

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Il Gyu; Choe, Yeon Hyeon; Han, Boo Kyung; Byun, Hong Sik; Choo, In Wook [Sungkyunkwan University College of Medicine, Seoul (Korea, Republic of)

    1999-02-01

    To evaluate the efficacy of stereotaxic breast core biopsy using a prone table system, and the effects of operator experience, lesion characteristics and number of samples on biopsy results in cases involving nonpalpable breast lesions. We performed stereotaxic core biopsies of 62 nonpalpable mammographic lesions in 61 patients. Subsequent surgical excision was performed in 11 cases with microcalcifications and one case with a mass. We equally divided patients with microcalcifications into two groups (early and late periods) and analyzed the mammographic findings. Correlation of the pathologic results of core biopsy with those of surgical excision were investigated. In two patients, stereotaxic biopsy was impossible due to poor visibility of microcalcifications and thinness of the compressed breast. In 59 patients, core biopsy was successfully performed and specimens were adequate for pathologic examination. The average number of microcalcifications seen on specimen mammography in the two groups was 1.8(range : 0x8) and 2.5(range : 0x4) respectively. In patients from whom less than five and five or more samples were taken, the average number of microcalcifications seen on specimen mammography was 1.5(range : 0x6) and 2.6(range : 0x8), respectively, throughout the whole period. The pathologic findings were fibrocystic change in 50 cases, fibroadenoma in four, ductal carcinoma in situ in four, invasive ductal carcinoma in one, and atypical ductal hyperplasia in one. The agreement rate of pathologic results between core biopsy and surgical excision was 83%(10/12) for malignancy and 75% for histology. In three cases with disagreement between core and surgical pathologic results, the sampling number was small (3x 4 times) and in two of the three cases, microcalcifications were not visible on mammography operator experience and sampling numbers larger than five results in an increased number of microcalcifications in specimens and more reliable core biopsy.

  10. Evaluation of fracture toughness of nuclear piping using real pipe and tensile compact pipe specimens

    International Nuclear Information System (INIS)

    Koo, J.M.; Park, S.; Seok, C.S.

    2013-01-01

    Highlights: • The tensile compact pipe (CP) specimen was proposed. • J-integral for the specimen was obtained by the plastic limit load analysis and FEA. • Fracture toughness tests by several types of specimens were performed and compared. • The constraint effects were considered by comparing Q-stresses for them. -- Abstract: The leak-before-break (LBB) concept is generally used to design the primary heat transport piping for a nuclear power plant. The LBB concept is based on the fracture resistance curve, which is obtained by J–R tests on various types of specimens. Fracture toughness data differ according to the various types of specimens. It has also been known that there is a difference in the constraint effect between real pipes and standard specimens, and LBB design using standard specimens is conservative. We propose a new type of specimen for J–R tests, a tensile compact pipe (CP) specimen, and perform fracture toughness tests on various types of specimens. We also perform constraint effect analysis on such specimens. The Q-stresses of the tensile CP specimens are lower than those of real pipes under 4-point bending, and are higher than those of elbow pipes. If the lever length of a tensile CP specimen is controlled, the specimen can simulate various stress conditions, and it is thought that the LBB design of piping in service can be performed using this specimen

  11. Evaluation of fracture toughness of nuclear piping using real pipe and tensile compact pipe specimens

    Energy Technology Data Exchange (ETDEWEB)

    Koo, J.M.; Park, S.; Seok, C.S., E-mail: seok@skku.edu

    2013-06-15

    Highlights: • The tensile compact pipe (CP) specimen was proposed. • J-integral for the specimen was obtained by the plastic limit load analysis and FEA. • Fracture toughness tests by several types of specimens were performed and compared. • The constraint effects were considered by comparing Q-stresses for them. -- Abstract: The leak-before-break (LBB) concept is generally used to design the primary heat transport piping for a nuclear power plant. The LBB concept is based on the fracture resistance curve, which is obtained by J–R tests on various types of specimens. Fracture toughness data differ according to the various types of specimens. It has also been known that there is a difference in the constraint effect between real pipes and standard specimens, and LBB design using standard specimens is conservative. We propose a new type of specimen for J–R tests, a tensile compact pipe (CP) specimen, and perform fracture toughness tests on various types of specimens. We also perform constraint effect analysis on such specimens. The Q-stresses of the tensile CP specimens are lower than those of real pipes under 4-point bending, and are higher than those of elbow pipes. If the lever length of a tensile CP specimen is controlled, the specimen can simulate various stress conditions, and it is thought that the LBB design of piping in service can be performed using this specimen.

  12. The diagnostic ability of an additional midline peripheral zone biopsy in transrectal ultrasonography-guided 12-core prostate biopsy to detect midline prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, In Pyeong; Kim, Sang Youn; Cho, Jeong Yeon; Lee, Myoung Seok; Kim, Seung Hyup [Dept. of Radiology, Seoul National University Hospital and Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul (Korea, Republic of)

    2016-01-15

    The goal of this study was to evaluate the diagnostic effect of adding a midline peripheral zone (PZ) biopsy to the 12-core biopsy protocol used to diagnose prostate cancer (PC), and to assess the clinical and pathologic characteristics of midline-positive PC in order to identify a potential subgroup of patients who would require midline PZ biopsy. This study included 741 consecutive patients who underwent a transrectal ultrasonography-guided, 12-core prostate biopsy with an additional midline core biopsy between October 2012 and December 2013. We grouped patients by the presence or absence of PC and subdivided patients with PC based on the involvement of the midline core. The clinical characteristics of these groups were compared, including serum prostate-specific antigen (PSA) concentrations, PSA density, and pathological features in the biopsy specimens. PC was detected in 289 patients (39.0%). Among the PC patients, 66 patients (22.8%) had midline PC. No patients were diagnosed with PC based only on a midline core. The Gleason scores, number of positive cores, tumor core length, serum PSA concentrations, and PSA density were significantly higher in patients with midline-positive PC (P<0.001). Furthermore, significant cancer was more frequent in the midline-positive group (98.5% vs. 78.0%). Patients showing a positive result for PC in a midline PZ biopsy were more likely to have multiple tumors or large-volume PC with a high tumor burden. However, our data indicated that an additional midline core biopsy is unlikely to be helpful in detecting occult midline PC.

  13. The Dugdale model for the compact specimen

    Science.gov (United States)

    Mall, S.; Newman, J. C., Jr.

    1983-01-01

    Plastic zone size and crack tip opening displacement (CTOD) equations were developed. Boundary collocation analyses were used to analyze the compact specimen subjected to various loading conditions (pin loads, concentrated forces, and uniform pressure acting on the crack surface). Stress intensity factor and crack surface displacement equations for some of these loadings were developed and used to obtain the Dugdale model. The results from the equations for plastic zone size and CTOD agreed well with numerical values calculated by Terada for crack length to width ratios greater than 0.4.

  14. The Dugdale model for compact specimen

    Science.gov (United States)

    Mall, S.; Newman, J. C., Jr.

    1985-01-01

    Plastic zone size and crack tip opening displacement (CTOD) equations were developed. Boundary collocation analyses were used to analyze the compact specimen subjected to various loading conditions (pin loads, concentrated forces, and uniform pressure acting on the crack surface). Stress intensity factor and crack surface displacement equations for some of these loadings were developed and used to obtain the Dugdale model. The results from the equations for plastic zone size and CTOD agreed well with numerical values calculated by Terada for crack length to width ratios greater than 0.4.

  15. High efficiency for prostate biopsy qualification with full-field OCT after training

    Science.gov (United States)

    Yang, C.; Ricco, R.; Sisk, A.; Duc, A.; Sibony, M.; Beuvon, F.; Dalimier, E.; Delongchamps, N. B.

    2016-02-01

    Full-field optical coherence tomography (FFOCT) offers a fast and non-destructive method of obtaining images of biological tissues at ultrahigh resolution, approaching traditional histological sections. In the context of prostate cancer diagnosis involving multiple biopsies, FFOCT could be used to validate the cores just after they are obtained in order to guide the number of biopsies to be performed. The aim of the study was to define and test a training protocol for efficient FFOCT prostate biopsy assessment. Three readers (a pathologist with previous experience with FFOCT, a pathologist new to FFOCT, and a urologist new to FFOCT) were trained to read FFOCT images of prostate biopsies on a set of 20 commented zooms (1 mm field of view) and 25 complete images. They were later tested on a set of 115 anonymized and randomized images of prostate biopsies. The results showed that an extra 30 images were necessary for more complete training as compared to prior studies. After training, pathologists obtained 100% sensitivity on high-grade cancer detection and 96% overall specificity; the urologist obtained 88% sensitivity on high-grade cancer and 89% overall specificity. Overall, the readers obtained a mean of 93% accuracy of qualifying malignancy on prostate biopsies. Moreover, the two pathologists showed a steeper learning curve than the urologist. This study demonstrates that a training protocol for such a new imaging modality may be implemented and yield very high efficiency for the pre-histologic detection of malignancy on prostate biopsies.

  16. Celioscopic liver biopsy in silver catfish (Rhamdia quelen

    Directory of Open Access Journals (Sweden)

    João P.S. Feranti

    2015-01-01

    Full Text Available Endosurgery has been used for assessment of fish celomatic cavity, as well as for obtaining biopsies for organic analysis. Such minimally invasive access may also be used for the analysis of environmental impact on biomarkers of pollution. In Brazil, studies and literature regarding the use of celioscopy in fish are sparse. The purpose of the current study was to develop a two-port celioscopy technique to obtain liver biopsy in silver catfish (Rhamdia quelen. Six adult female silver catfish were used. The animals were anesthetized and the inspection of the celomatic cavity were performed using a telescope and celioscopic-guided liver biopsy were taken using laparoscopic Kelly forceps. On the early postoperative period, the animals were released in a confined water reservoir where mortality could be checked. The liver samples were sent for histological assessment. There were no complications during surgery on early postoperative period. It was possible to visualize meticulously several organs (liver, spleen, stomach, pancreas, swim bladder, ovaries, bowel and transverse septum. In conclusion, the surgical technique and the anesthetic protocol proposed were suitable to perform liver biopsies in silver catfish and provided low morbidity.

  17. Percutaneous renal graft biopsy: a clinical, laboratory and pathological analysis

    Directory of Open Access Journals (Sweden)

    Marilda Mazzali

    1999-03-01

    Full Text Available CONTEXT: Renal allograft biopsies have been used as a good method for monitoring the evolution of kidney transplants for at least 20 years.1 Histological analysis permits differential diagnosis of the causes of allograft dysfunction to be made. OBJECTIVES: To correlate the data of urinalysis and serum creatinine with histological diagnosis of renal graft in a group of renal transplant patients. DESIGN: Accuracy study, retrospective analysis. SETTING: A university terciary referral center. SAMPLE: 339 percutaneous allograft biopsies obtained from 153 patients. Blood and urine samples were obtained before the graft biopsy. MAIN MEASUREMENTS: Laboratory evaluation and hystological analysis (light microscopy, imunofluorescent eletronic microscopy. RESULTS: Most of the biopsies (58.9% were performed during the first month post-transplant. An increase in serum creatinine was associated with acute tubular and/or cortical necrosis. Proteinuria and normal serum creatinine were associated with glomerular lesions. Non-nephrotic range proteinuria and an increase in serum creatinine were associated with chronic rejection. CONCLUSIONS: Evaluation of serum creatinine and urinalysis can be useful in suggesting the histological graft diagnosis.

  18. Screening for Helicobacter pylori in Idiopathic Pulmonary Fibrosis Lung Biopsies.

    Science.gov (United States)

    Kreuter, Michael; Kirsten, Detlef; Bahmer, Thomas; Penzel, Roland; Claussen, Martin; Ehlers-Tenenbaum, Svenja; Muley, Thomas; Palmowski, Karin; Eichinger, Monika; Leider, Marta; Herth, Felix J F; Rabe, Klaus F; Bittmann, Iris; Warth, Arne

    2016-01-01

    Increasing evidence suggests a role of gastro-oesophageal reflux (GER) in idiopathic pulmonary fibrosis (IPF) pathogenesis. Recently, an association between serum Helicobacter pylori (HP) antibody positivity and more severe disease was described, but HP has not been directly analysed in lung tissue so far. To investigate the presence of HP in the lung tissue of IPF patients. Two tertiary interstitial lung disease care centre databases were screened for available lung biopsy material from IPF patients. Clinical and radiological data, including presence of GER and antiacid medication, were evaluated. HP-specific PCR was carried out on the IPF lung biopsy specimens. A total of 39 IPF patients were included, of whom 85% were male. The patients' median age was 66 years, their vital capacity was 79% predicted, and their diffusing capacity for carbon monoxide was 53% predicted. In all, 82% of the lung biopsies were surgical and 18% transbronchial. Comorbidities were GER disease in 23% (n = 9), sleep apnoea in 13% (n = 5) and hiatal hernia in 38% of the cases (n = 15). Proton pump inhibitors were prescribed at the time of biopsy in 21% of the cases (n = 9). After a median follow-up of 25 months (range 6-69), there were 1 death, 1 lung transplantation and 8 acute exacerbations without relevant differences between the GER and non-GER subgroups. HP DNA was not detected in any of the lung tissue samples. The fact that no HP DNA was detected in the lung tissues calls into question the proposed relevance of HP to the direct pathogenesis of IPF. © 2015 S. Karger AG, Basel.

  19. Case report of a 28-year-old male with the rapid progression of steroid-resistant central nervous system vasculitis diagnosed by a brain biopsy.

    Science.gov (United States)

    Takahashi, Keigo; Sato, Hideki; Hattori, Hidenori; Takao, Masaki; Takahashi, Shinichi; Suzuki, Norihiro

    2017-09-30

    A 28-year-old Japanese male without a significant past medical history presented with new-onset generalized clonic seizure and headache. A brain MRI revealed multiple enhanced lesions on both cerebral hemispheres. Laboratory exams showed no evidence of systemic inflammation or auto-immune antibodies such as ANCAs. Despite four courses of high-dose methylprednisolone pulse therapy and five treatments with plasmapheresis, his symptoms worsened and the MRI lesions progressed rapidly. During these treatments, we performed a targeted brain biopsy, that revealed histological findings consistent with a predominant angiitis of parenchymal and subdural small vessels. He was provided with diagnosis of central nervous system vasculitis (CNSV). Subsequent cyclophosphamide pulse therapy enabled a progressive successful improvement of his symptoms. While diagnostic methods for CNSV remain controversial, histological findings are thought to be more useful in obtaining a more definitive diagnosis than findings in image studies, such as MRI and angiography. We suggest that a brain biopsy should be considered during the early period of cases with suspected CNSV and rapid clinical deterioration. We also detected human herpesvirus 7 (HHV-7) using PCR technology in brain biopsy specimens, however the relationship between CNSV and HHV-7 infection is unknow.

  20. Primary Signet Ring Cell Carcinoma of Rectum Diagnosed by Boring Biopsy in Combination with Endoscopic Mucosal Resection

    Directory of Open Access Journals (Sweden)

    Yoshito Hirata

    2018-01-01

    Full Text Available A 46-year-old man with severe back pain visited our hospital. Magnetic resonance imaging revealed extensive bone metastasis and rectal wall thickness. Colonoscopy revealed circumferential stenosis with edematous mucosa, suggesting colon cancer. However, histological findings of biopsy specimens revealed inflammatory cells but no malignant cells. The patient underwent endoscopic ultrasound, which demonstrated edematous wall thickness without destruction of the normal layer structure. After unsuccessful detection of neoplastic cells by boring biopsies, we performed endoscopic mucosal resection followed by boring biopsies that finally revealed signet ring cell carcinoma. Herein, we present a case and provide a review of the literature.

  1. Biopsy-proven childhood glomerulonephritis in Johor.

    Science.gov (United States)

    Khoo, J J; Pee, S; Thevarajah, B; Yap, Y C; Chin, C K

    2004-06-01

    There has been no published study of biopsy-proven childhood glomerulonephritis in Malaysia. To determine the pattern of childhood glomerulonephritis in Johor, Malaysia from a histopathological perspective and the various indications used for renal biopsy in children. Retrospective study was done of all renal biopsies from children under 16 years of age, received in Sultanah Aminah Hospital, Johor between 1994 and 2001. The histopathological findings were reviewed to determine the pattern of biopsy-proven glomerulonephritis. The indications for biopsy, mode of therapy given after biopsy and the clinical outcome were studied. 122 adequate biopsies were received, 9 children had repeat biopsies. Of the 113 biopsies, minimal change disease formed the most common histopathological diagnosis (40.7%) while lupus nephritis formed the most common secondary glomerulonephritis (23.0%). The main indications for biopsy were nephrotic syndrome (50.8%), lupus nephritis (25.4%) and renal impairment (13.1%). The mode of therapy was changed in 59.8% of the children. Of 106 patients followed-up, 84 children were found to have normal renal function in remission or on treatment. 4 patients developed chronic renal impairment and 16 reached end stage renal disease. Five of the 16 children with end stage disease had since died while 11 were on renal replacement therapy. Another 2 patients died of other complications. The pattern of childhood GN in our study tended to reflect the more severe renal parenchymal diseases in children and those requiring more aggressive treatment. This was because of our criteria of selection (indication) for renal biopsy. Renal biopsy where performed appropriately in selected children may not only be a useful investigative tool for histological diagnosis and prognosis but may help clinicians plan the optimal therapy for these children.

  2. Computed tomography guided needle biopsy: experience from 1,300 procedures

    Energy Technology Data Exchange (ETDEWEB)

    Chojniak, Rubens; Isberner, Rony Klaus; Viana, Luciana Marinho; Yu, Liao Shin; Aita, Alessandro Amorim; Soares, Fernando Augusto [Hospital do Cancer A.C. Camargo, Sao Paulo, SP (Brazil). Dept. de Radiologia e Patologia

    2006-01-15

    Context and objective: computed tomography (CT) guided biopsy is widely accepted as effective and safe for diagnosis in many settings. Accuracy depends on target organ and needle type. Cutting needles present advantages over fine needles. This study presents experience from CT guided biopsies performed at an oncology center. Design and setting: retrospective study at Hospital do Cancer A. C. Camargo, Sao Paulo.Methods: 1,300 consecutive CT guided biopsies performed between July 1994 and February 2000 were analyzed. Nodules or masses were suspected as primary malignancy in 845 cases (65%) or metastatic lesion in 455 (35%). 628 lesions were thoracic, 281 abdominal, 208 retroperitoneal, 134 musculoskeletal and 49 head/neck. All biopsies were performed by one radiologist or under his supervision: 765 (59%) with 22-gauge fine-needle/aspiration technique and 535 (41%) with automated 16 or 18-gauge cutting-needle biopsy. Results: adequate samples were obtained in 70-92% of fine-needle and 93-100% of cutting-needle biopsies. The specific diagnosis rates were 54-67% for fine-needle and 82-100% for cutting-needle biopsies, according to biopsy site. For any site, sample adequacy and specific diagnosis rate were always better for cutting-needle biopsy. Among 530 lung biopsies, there were 84 pneumothorax (16%) and two hemothorax (0.3%) cases, with thoracic drainage in 24 (4.9%). Among abdominal and retroperitoneal biopsies, there were two cases of major bleeding and one of peritonitis. Conclusion: both types of needle showed satisfactory results, but cutting-needle biopsy should be used when specific diagnosis is desired without greater incidence of complications. (author)

  3. Diagnosis of metastatic tumours to the thyroid gland by fine needle aspiration biopsy.

    Science.gov (United States)

    Buła, Grzegorz; Waler, Janusz; Niemiec, Andrzej; Koziołek, Henryk; Bichalski, Wojciech; Gawrychowski, Jacek

    2010-01-01

    Malignant metastases are rarely found in the thyroid gland, the incidence reaching approximately 2% of all thyroid malignant neoplasms. They are most often caused by tumours of the kidneys, lungs, mammary glands, ovary, and colon or by melanomas. The aim of the study was to evaluate the usefulness of fine needle aspiration biopsy (FNA) for diagnosing tumour metastases to thyroid glands. A total of 15122 patients were operated between 1990 and 2009 for goitres. Malignant neoplasm was diagnosed in 733 (4.8%) patients. Malignant metastases to the thyroid gland were detected in 10 patients, namely 2 men and 8 women aged 48-89 years. The group made up 1.4% of all patients operated for malignant thyroid tumour. Preoperative diagnostic procedure consisted of thyroid scintigraphy, thyroid ultrasonography, and cytology of the material obtained through FNA. In addition, the hormonal activity of the thyroid gland was examined. The range of operation was established through clinical assessment of the tumour, preoperative cytology, and intra-operative histopathology. Among 7 patients with thyroid metastases from renal clear cell carcinoma, as diagnosed postoperatively, cytology of the thyroid material obtained through FNA revealed follicular tumour in 3 (43%) patients, tumour cells in 2 (28.5%) and atypical cells in the other 2 (28.5%). Intraoperative histopathology confirmed the presence of metastasis from renal clear cell carcinoma (1) and indicated thyroid medullary cancer (1), follicular tumour (4), or trabecular adenoma with necrosis (1). Among two patients with thyroid metastases from breast cancer, cytology confirmed a metastasis from breast cancer in one (the woman was disqualified for surgical treatment) and indicated follicular tumour in one. Intraoperative histopathology suggested thyroid anaplastic cancer. Examination of biopsy specimen revealed epithelial cells accompanied by cell atypia in one patient with thyroid metastasis from lung cancer. Intra

  4. Can Sonovue targeted biopsy replace extended or saturation biopsy in prostate cancer diagnosis? Our experience at primary and repeat biopsy.

    Science.gov (United States)

    Pepe, Pietro; Candiano, Giuseppe; Pennisi, Michele; Aragona, Francesco

    2010-09-01

    To evaluate the detection rate of prostate cancer (PCa) at initial and repeat biopsy in patients submitted to Sonovue targeted biopsy vs extended or saturation prostate biopsy (SPBx). From November 2007 to April 2008 60 patients aged 64 years (median) underwent extended TRUS-guided transperineal prostate biopsy. Indications to biopsy were: abnormal DRE, PSA > 10 ng/mL; PSA included between 2.6 and 4.0 and 4.1 and 10 ng/mL with %free/total PSA digital rectal examination was positive in 9 vs 3 patients, respectively. Before performing extended or SPBx scheme in case of primary (19 cores) and repeated (28 cores) procedure, prostate areas characterized by absence of enhancement after Sonovue (2.4 mg) administration on gray scale during continuous harmonic imaging (HI) contrast-enhanced ultrasound (CEUS) were considered suspicious for PCa and submitted to targeted biopsy. 3.5 (median) targeted biopsies were performed in the peripheral zone of 22 men. In patients who underwent primary and repeated biopsy PCa was detected in 20/45 (44.5%) and 3/15 (20%) cases, but Sonovue detected only 6/20 (30%) and 1/3 (33.4%) of cancers, respectively. Sensitivity and specificity of Sonovue in diagnosing PCa was equal to 30.0% and 61.5% (primary biopsy) vs 33.4% and 54.5% (repeated biopsy). Based on its low diagnostic accuracy, Sonovue CEUS HI targeted biopsy can not replace extended or SPBx in diagnosing PCa.

  5. Nerve Biopsy In The Diagnosis Of Leporsy

    Directory of Open Access Journals (Sweden)

    Hazra B

    1997-01-01

    Full Text Available Skin and nerve biopsies were done in 33 cases of different clinical types of leprosy selected from Dermatology OPD of Medical College and Hospitals, Calcutta during 1994-95. Histopathological results were compared with emphasis on the role of nerve biopsies in detection of patients with multibacillary leprosy. The evident possibility of having patients with multibacillary leprosy in peripheral leprosy with multiple drugs. It is found that skin and nerve biopsy are equally informative in borderline and lepromatour leprosy and is the only means to diagnose polyneuritic leprosy. Nerve biopsy appears to be more informative in the diagnosis of all clinical types of leprosy.

  6. The diagnostic value of liver biopsy

    Directory of Open Access Journals (Sweden)

    Zimmermann Arthur

    2001-10-01

    Full Text Available Abstract Background Since the introduction of molecular diagnostic tools such as markers for hepatitis C and different autoimmune diseases, liver biopsy is thought to be useful mainly for staging but not for diagnostic purposes. The aim was to review the liver biopsies for 5 years after introduction of testing for hepatitis C, in order to evaluate what diagnostic insights – if any – remain after serologic testing. Methods Retrospective review of all liver biopsies performed between 1.1.1995 and 31.12.1999 at an academic outpatient hepatology department. The diagnoses suspected in the biopsy note were compared with the final diagnosis arrived at during a joint meeting with the responsible clinicians and a hepatopathologist. Results In 365 patients, 411 diagnoses were carried out before biopsy. 84.4 % were confirmed by biopsy but in 8.8 %, 6.8 % and 10.5 % the diagnosis was specified, changed or a diagnosis added, respectively. Additional diagnoses of clinical relevance were unrecognized biliary obstruction and additional alcoholic liver disease in patients with chronic hepatitis C. Liver biopsy led to change in management for 12.1 % of patients. Conclusion Even in the era of advanced virological, immunological and molecular genetic testing, liver biopsy remains a useful diagnostic tool. The yield is particularly high in marker negative patients but also in patients with a clear-cut prebiopsy diagnosis, liver biopsy can lead to changes in patient management.

  7. Robotic Prostate Biopsy in Closed MRI Scanner

    National Research Council Canada - National Science Library

    Fischer, Gregory

    2008-01-01

    .... This work enables prostate brachytherapy and biopsy procedures in standard high-field diagnostic MRI scanners through the development of a robotic needle placement device specifically designed...

  8. Needle muscle biopsy and its application

    Directory of Open Access Journals (Sweden)

    Meng-long CHEN

    2015-07-01

    Full Text Available Needle muscle biopsy is a straightforward and reliable minimally-invasive technique. During the past century, the needle biopsy can provide adequate samples and the technique has gradually gained wider acceptance. Compared with open biopsy, needle biopsy is less traumatic, with low rate of complications, and is suitable for the identifications and evaluations of muscular dystrophy, inflammatory myopathies and systemic diseases involving muscles, specially for infants and young children. Domestic insiders should be encouraged to apply this technique. DOI: 10.3969/j.issn.1672-6731.2015.06.003 

  9. A validated method of labial minor salivary gland biopsy for the diagnosis of Sjögren's syndrome.

    Science.gov (United States)

    Kim, Jean; Sun, Daniel; Ozl, Rebecca; Grader-Beck, Thomas; Birnbaum, Julius; Akpek, Esen K; Baer, Alan N

    2016-09-01

    To validate a technique and outcomes of labial minor salivary gland biopsy (LSGB) used for the diagnosis of Sjögren's syndrome (SS). Prospective cohort study. Clinical data were prospectively obtained pre- and postbiopsy using patient-reported questionnaires. LSGB was performed using described methods. Specimens were analyzed by a pathologist with expertise in SS and assessed using established criteria to determine the focus score. Data were analyzed using cross-tabulations. Among the 58 patients in the study, 52 (90%) presented with sicca symptoms of dry eyes and/or mouth. Eight patients (14%) had histopathologic findings supportive of a diagnosis of SS. At 1 month postbiopsy, greater than 71% of patients denied any complaints of pain, swelling, numbness. or tingling. Sixteen patients (28%) had only a minor level of complaints. Only one patient complained of severe numbness at the biopsy site. Greater than 70% of patients would consider rebiopsy after the procedure, if requested by their physician. We present a safe and effective method of LSGB for the diagnosis of SS. 4 Laryngoscope, 126:2041-2046, 2016. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.

  10. Is it possible to predict low-volume and insignificant prostate cancer by core needle biopsies?

    DEFF Research Database (Denmark)

    Berg, Kasper Drimer; Toft, Birgitte Grønkaer; Røder, Martin Andreas

    2013-01-01

    M: tumour ≤5% of total prostate volume and prostate-specific antigen (PSA) ≤10 ng/mL. In all definitions, Gleason score (GS) was ≤6 and the tumour was organ confined. Biopsies alone performed poorly as a predictor of unifocal and unilateral cancer in the prostatectomy specimens with positive predictive...... values of 17.8% and 18.9% respectively. Inclusion of other clinical and biochemical parameters did not significantly increase the predictive value. However, the combination of GS ≤ 6, PSA ≤ 10 ng/mL and unifocal or unilateral cancer in biopsy cores resulted in a positive predictive value of 61.1%, 38...

  11. Indications for extended 14-core transrectal ultrasound-guided prostate biopsy.

    Science.gov (United States)

    Uno, Hiromi; Nakano, Masahiro; Ehara, Hidetoshi; Deguchi, Takashi

    2008-01-01

    We compared the cancer detection rate of extended 14-core biopsy with that of sextant biopsy to assess whether additional biopsy cores are useful for detection of prostate cancer and to clarify the indications for obtaining additional cores. Study subjects were 313 patients who underwent transrectal ultrasound-guided 14-core biopsy because of a prostate-specific antigen (PSA) level greater than 4.0 ng/mL and/or abnormalities found on digital rectal examination (DRE). In addition to the standard 6 biopsy cores, 6 lateral cores were obtained as well as 2 transition zone cores. PSA density (PSAD) was determined as the total PSA level divided by the prostate volume as estimated by transrectal ultrasound. Prostate cancer was diagnosed in 127 patients (40.6%). In 28 (22%) patients, the cancer would not have been detected by the sextant method alone. Among 211 patients with normal DRE findings, the cancer detection rate with 14-core biopsy was statistically higher than that with 6-core biopsy in the 141 patients with a PSA level of 4.01 ng/mL to 10.0 ng/mL, and 14 (38.9%) of 36 cancers were diagnosed in additional cores only, not in the standard sextant biopsy cores. Among the 141 patients with a gray-zone PSA level, the cancer detection rate with extended biopsy was statistically higher in those with PSAD greater than 0.13 ng/mL. Lateral biopsy should be used in conjunction with sextant biopsy in patients with a PSA level of 4.01 ng/mL to 10.0 ng/mL with normal DRE findings, especially in those with PSAD greater than 0.13 ng/mL.

  12. A quantitative swab is a good non-invasive alternative to a quantitative biopsy for quantifying bacterial load in wounds healing by second intention in horses.

    Science.gov (United States)

    Van Hecke, L L; Hermans, K; Haspeslagh, M; Chiers, K; Pint, E; Boyen, F; Martens, A M

    2017-07-01

    The aim of this study was to evaluate different techniques for diagnosing wound infection in wounds healing by second intention in horses and to assess the effect of a vortex and sonication protocol on quantitative bacteriology in specimens with a histologically confirmed biofilm. In 50 wounds healing by second intention, a clinical assessment, a quantitative swab, a semi-quantitative swab, and a swab for cytology were compared to a quantitative tissue biopsy (reference standard). Part of the biopsy specimen was examined histologically for evidence of a biofilm. There was a significant, high correlation (Pquantitative swabs and the quantitative biopsies. The semi-quantitative swabs showed a significant, moderate correlation with the quantitative biopsies (Pquantitative swab is an acceptable non-invasive alternative to a quantitative biopsy for quantifying bacterial load in equine wounds healing by second intention. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. A review on the use of bulk specimen X-ray microanalysis in cancer research

    International Nuclear Information System (INIS)

    Zs-Nagy, I.

    1989-01-01

    The freeze-fracture, freeze-drying (FFFD) method of biological bulk specimen preparation combined with quantitative X-ray microanalysis is suitable for the measurement of intracellular concentrations of biologically relevant elements in human biopsy or experimental animal materials. Especially useful information can be obtained regarding the intracellular Na+/K+ ratios being independent of the actual (and unknown) water content of the cytoplasm. The sustained increase of this ratio indicates a sustained depolarization of the cell membrane. These data are of importance from the point of view of the membrane hypothesis of mitogenesis (MHM). It has been revealed that the distribution histograms of the intracellular Na+/K+ ratio display a very significant broadening and an increase of the average values in human urogenital, thyroid and laryngeal tumors, as well as in experimentally induced cell proliferation models. Although MHM has been claimed to be invalid on the basis of some atomic absorption measurements of the intracellular monovalent ion concentrations as well as of some in vitro results obtained with amiloride, this review paper demonstrates that MHM may still be a valid hypothesis for the explanation of mitotic regulation.97 references

  14. Effect of specimen size on the fracture toughness of V-4Cr-4Ti

    Energy Technology Data Exchange (ETDEWEB)

    Kurtz, R.J.; Jones, R.H. [Pacific Northwest National Laboratory, Richland, WA (United States); Li, Huaxin

    1996-04-01

    J-R curves were generated using the single specimen unload-compliance technique on four specimens of V-4Cr-4Ti to determine the effect of specimen dimensions on the fracture behavior. Ductile crack initiation and growth was observed in the 6.35 mm thick specimens but not in the 12.70 mm thick specimens. The J-R curves determined from these tests were not valid per ASTM validity criteria so quantitative measures of the resistance to ductile crack initiation and growth were not obtained. These data suggests that standard fracture toughness tests were performed with small-scale DCT specimens may also not be valid.

  15. Creep test with use of miniaturized specimens

    Science.gov (United States)

    Chvostová, E.; Džugan, J.

    2017-02-01

    Application of the mini samples methods is very common especially for residual service life assessment of the components operating in the energy sector. Residual lifetime of operating device can be evaluated using standard tests, but these usually cannot be performed due to limited material amount that can be extracted from the components. It is possible to use in these cases a semi destructive sampling of materials and testing methods employing miniature specimens. This article deals with comparison of the creep results obtained with the use of on standard test bars and sub sized samples such as Small Punch Test and newly proposed miniature samples that are axially loaded. The experiment was performed on steam line steel CSN 15 128 after operation. Emphasis was put to practical use of the test results and therefore residual life was assessed with the use of standard and new mini specimens. The results obtained for standard and mini samples exhibit very good agreement without necessity of any correlation as in the case of SPT and thus much more straight forward approach can be applied even for “unknown materials”.

  16. Reheating of zinc-titanate sintered specimens

    Directory of Open Access Journals (Sweden)

    Labus N.

    2015-01-01

    Full Text Available The scope of this work was observing dimensional and heat transfer changes in ZnTiO3 samples during heating in nitrogen and air atmosphere. Interactions of bulk specimens with gaseous surrounding induce microstructure changes during heating. Sintered ZnTiO3 nanopowder samples were submitted to subsequent heating. Dilatation curves and thermogravimetric with simultaneous differential thermal analysis TGA/DTA curves were recorded. Reheating was performed in air and nitrogen atmospheres. Reheated samples obtained at different characteristic temperatures in air were analyzed by X-ray diffraction (XRD. Microstructures obtained by scanning electron microscopy (SEM of reheated sintered samples are presented and compared. Reheating in a different atmosphere induced different microstructures. The goal was indicating possible causes leading to the microstructure changes. [Projekat Ministarstva nauke Republike Srbije, br. OI172057 i br. III45014

  17. Percutaneous transluminal biopsy using 7F forceps for diagnosing malignant biliary obstruction

    Energy Technology Data Exchange (ETDEWEB)

    Bahn, Young Eun; Kim, Young Hwan; An, Eun Jung; Kim, See Hyung [Keimyung Univ. College of Medicine, Daegu (Korea, Republic of)

    2012-07-15

    To evaluate the usefulness of the percutaneous transluminal biopsy using 7-F forceps for diagnosing malignant biliary obstruction. One hundred and seven consecutive patients with obstructive jaundice underwent transluminal forceps biopsy. The lesions involved the common bile duct (n = 33), common hepatic duct (n = 13), hilum (n = 17), right or left intrahepatic bile duct (n = 32), multiple sites (extra and intrahepatic ducts, n = 7), or anastomotic sites (n = 5). In each patient, an average of three specimens was taken with 7F biopsy forceps through a transhepatic biliary drainage tract. The final diagnosis was confirmed with pathologic findings, or a clinical and radiologic follow up. The final diagnoses showed malignancies in 75 patients and benign biliary obstructions in 32 patients. Pathologic classifications of malignancies established by forceps biopsy included 67 adenocarcinomas, 1 adenosquamous cell carcinoma, and 1 hepatocelluar carcinoma. There were 6 false-negative diagnoses. The diagnostic performance of transluminal forceps biopsy in malignant biliary obstruction had a sensitivity of 92%, specificity of 100%, positive predictive value of 100%, a negative predictive value of 84.2%, and an accuracy of 94.2%. Percutaneous transluminal forceps biopsy is a safe procedure that is easy to perform through a transhepatic biliary drainage tract. It is a highly accurate technique for diagnosing malignant biliary obstructions.

  18. Identifying pathogens of spondylodiscitis: percutaneous endoscopy or CT-guided biopsy.

    Science.gov (United States)

    Yang, Shih-Chieh; Fu, Tsai-Sheng; Chen, Lih-Huei; Chen, Wen-Jer; Tu, Yuan-Kun

    2008-12-01

    Identifying offending pathogens is crucial for appropriate antibiotic administration for infectious spondylitis. Although computed tomography (CT)-guided biopsy for bacteriologic diagnosis is a standard procedure, it has a variable success rate. Some reports claim percutaneous endoscopic discectomy and drainage offer a sufficient amount of tissue for microbiologic examination and easy application. We therefore compared the diagnostic value of CT guidance with that of endoscope guidance in 52 patients with suspected infectious spondylitis. Twenty patients underwent percutaneous endoscopic discectomy and drainage by an orthopaedic surgeon and the other 32 patients underwent CT-guided biopsies by a radiologist. Patients were followed a minimum of 12 months after treatment. Culture results of the biopsy specimens were recorded. Causative bacteria were identified more frequently with percutaneous endoscopy than in CT-guided biopsy (18 of 20 [90%] versus 15 of 32 [47%]). We observed no biopsy-related complications or side effects in either group. The data suggest percutaneous endoscopic discectomy and drainage yield higher bacterial recovery rates than CT-guided spinal biopsy. Level III, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.

  19. Accuracy of HER2 status determination on breast core-needle biopsies (immunohistochemistry, FISH, CISH and SISH vs FISH).

    Science.gov (United States)

    Arnould, Laurent; Roger, Pascal; Macgrogan, Gaëtan; Chenard, Marie-Pierre; Balaton, André; Beauclair, Sophie; Penault-Llorca, Frederique

    2012-05-01

    Preoperative breast cancer diagnosis on core biopsies has become a standard of care in many countries. Controversies exist concerning the accuracy of HER2 testing on biopsies as compared with surgical specimens, and few data exist concerning the use of emerging technologies such as bright-field in-situ hybridization in such a setting. A French multicenter, cross-sectional, histopathological study assessed the concordance of HER2 status determined by immunohistochemistry and silver (SISH) or chromogenic in-situ hybridization (CISH) on core-needle biopsies with HER2 status determined by fluorescence in-situ hybridization (FISH) on surgical specimens. The concordance between biopsy and operative results was also assessed for each method. We studied 260 breast tumors from 24 centers between April 2003 and August 2009. Excellent concordance (κ: 0.92-0.97) was shown between immunohistochemistry and FISH with low discordance rates (2-4%), high specificity (97-98%) and sensitivity values (95-99%), with no significant difference according to the immunohistochemistry interpretation guidelines used. The correlation between SISH and CISH on biopsies and FISH on surgical samples was strong (κ: 0.96 and 0.94, respectively), with no significant difference between false negative rates or sensitivity and specificity values (2 and 5%, 99 and 96%, 98 and 98%, respectively). Whatever the evaluation technique, excellent concordance between biopsies and surgical specimens was observed (κ ≥ 0.97; discordance rates between 1 and 2%), with high sensitivity (98-99%) and specificity (98-100%). Based on these results, when FISH cannot be used, SISH and/or CISH could be proposed as an alternative method to determine HER2 status and to confirm any ambiguous immunohistochemistry results, either for preoperative percutaneous biopsies or for surgical specimens. They could also be used for quality controls and immunohistochemistry calibration.

  20. Testicular biopsy: Clinical practice and interpretation

    NARCIS (Netherlands)

    G.R. Dohle (Gert); S. Elzanaty (Saad); N.J. van Casteren (Niels)

    2012-01-01

    textabstractTesticular biopsy was considered the cornerstone of male infertility diagnosis for many years in men with unexplained infertility and azoospermia. Recent guidelines for male infertility have limited the indications for a diagnostic testicular biopsy to the confirmation of obstructive

  1. Ultrasound guided synovial biopsy of the wrist

    NARCIS (Netherlands)

    van Vugt, R. M.; van Dalen, A.; Bijlsma, J. W.

    1997-01-01

    Seven patients (4 female and 3 male, mean age 46) with arthritis of the wrist (n = 7) without known etiology were evaluated. High-definition ultrasound equipment was used for localization of synovial hypertrophy, suitable for ultrasound guided biopsy without risk. A 18-gauge diameter Tru-cut biopsy

  2. The criteria for the decision of transrectal US-guided prostate biopsy: Can we reduce the number of unnecessary biopsies?

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Joon Hyung; Cho, Jae Ho; Ahn, Jay Hong; Chang, Jay Chun [Yeungnam University College of Medicine, Taegu (Korea, Republic of)

    2001-09-15

    To establish the criteria which can safely reduce the number of unnecessary biopsies by comparing the transrectal ultrasonography (TRUS) findings, serum prostate-specific antigen (PSA), and prostate specific antigen density (PSAD) in the decision of criteria for the prostatic biopsy using TRUS. Two hundred and twenty patients underwent TRUS- guided prostate biopsy due to elevated PSA and/or focal nodule on TRUS were included. Sixty five (27.5%) patients were confirmed as prostate cancer, and remained 155 (70.5%) patients were reported as benign diseases including benign prostate hyperplasia. The sensitivity, specificity and accuracy of TRUS, PSA and PSAD were evaluated and the single criterion or the combination of the criteria which can safely reduce the unnecessary biopsies without missing prostatic cancer were investigated. The sensitivity, specificity and accuracy of TRUS, PSA (cut-off value, 4 ng/ml) and PSAD (cut-off level, 0.2 ng/ml/cm{sup 3}) were 78.5%/95.4%/95.4%/27.8%/51.6%/64/5%, 42.7%/64.5%/73.6%, respectively. PSAD cut-off level 0.2 ng/ml/cm{sup 3} was the most excellent single criterion for the decision of prostatic biopsy and the number of unnecessary biopsies was 100 cases. But 3 cases of prostatic cancer which the PSAD level was below 0.2 ng/ml/cm{sup 3} were included and in all these 3 cases, a focal nodule was detected on TRUS. Therefore, we applied these two criteria at once and the biopsies of 30 cases (13.6%) are unnecessary. With the single criterion, we could not obtain the satisfactory results but by the combinations of criteria (TRUS and PSAD), 30 (13.6%) cases are unnecessary biopsies without missing cancer. We think that the short term follow-up may be a substitute for the immediate when nodular lesion is suspicious on TRUS and serum PSAD level is below 0.2 ng/ml/cm{sup 3}.

  3. Coeliac disease: to biopsy or not?

    Science.gov (United States)

    Reilly, Norelle R; Husby, Steffen; Sanders, David S; Green, Peter H R

    2018-01-01

    Coeliac disease is increasingly recognized as a global problem in both children and adults. Traditionally, the findings of characteristic changes of villous atrophy and increased intraepithelial lymphocytosis identified in duodenal biopsy samples taken during upper gastrointestinal endoscopy have been required for diagnosis. Although biopsies remain advised as necessary for the diagnosis of coeliac disease in adults, European guidelines for children provide a biopsy-sparing diagnostic pathway. This approach has been enabled by the high specificity and sensitivity of serological testing. However, these guidelines are not universally accepted. In this Perspective, we discuss the pros and cons of a biopsy-avoiding pathway for the diagnosis of coeliac disease, especially in this current era of the call for more biopsies, even from the duodenal bulb, in the diagnosis of coeliac disease. In addition, a contrast between paediatric and adult guidelines is presented.

  4. Breast carcinoma in radiosurgery biopsy

    International Nuclear Information System (INIS)

    Cohen, Leonard O.; Brito, Pablo E.; Coppolecchia, German L.; Giarmana, Maria J.; Delle Ville, Rodolfo E.; Cortese, Eduardo M.

    2006-01-01

    Purpose: To report our experience on the detection of breast cancer (BC) through guided radiosurgical biopsies (GRSB) in the Gynecology Department of the Hospital Aeronautico Central (SGHAC). Materials and method: We retrospectively analyzed 622 GRSBs performed at the SGHAC between 1 January 1995 and 31 December 2004. We took into account single or associated lesions found in mammograms, which we subdivided into four types: 1) Non-palpable mammographic nodules; 2) Microcalcifications; 3) Structural distortions; 4) Mammographic asymmetries. Results: We found 332 non-palpable nodules (53.4%), 214 microcalcifications (34.4%), 40 structural distortions (6.4%), and 36 mammographic asymmetries (5.8%). Out of the 622 GRSBs performed during the above period, 152 BCs were diagnosed, that is, an incidence of 24.4% detected through this method. Out of the 152 BCs, 110 (72.4%) were invasive and 42 (27.6%) were noninvasive. Conclusions: Although 24.4% of BCs were identified through GRSBs, our tea m considers this to be the standard method for early detection of breast cancer. (author) [es

  5. BI-26HOW MUCH INSIGHT CAN A STEREOTACTIC BIOPSY DELIVER?

    OpenAIRE

    Timmer, Marco; Perrech, Moritz; Röhn, Gabriele; Rueß, Daniel; Blau, Tobias; Breuer, Nadine; Galldiks, Norbert; Goldbrunner, Roland; Ruge, Maximilian

    2014-01-01

    INTRODUCTION: Besides standard evaluation of histology, immunology and molecular markers as MGNT, IDH etc. an additional screening for biomarkers, genetic alterations and epigenetic features deriving from tissue from primary or recurrent brain tumors may harbor potential as prognostic and predictive information. With this pilot study we intended to examine in how far tissue obtained by stereotactic biopsy can be utilized for extended evaluation. METHODS: Stereotactically guided serial tissue ...

  6. Risk factors for bleeding complications after nephrologist-performed native renal biopsy.

    Science.gov (United States)

    Lees, Jennifer S; McQuarrie, Emily P; Mordi, Natalie; Geddes, Colin C; Fox, Jonathan G; Mackinnon, Bruce

    2017-08-01

    Bleeding is a recognized complication of native percutaneous renal biopsy. This study aimed to describe the incidence of major bleeding after biopsy in a single centre over a 15-year period and examine factors associated with major bleeding. We identified consecutive adult patients undergoing ultrasound-guided native renal biopsy in the Glasgow Renal and Transplant Unit from 2000 to 2014. From the electronic patient record, we collected data pertaining to biopsy indication, pre- and post-biopsy laboratory measurements, prescribed medication and diagnosis. Aspirin was routinely continued. We defined major bleeding post-biopsy as the need for blood transfusion, surgical or radiological intervention or death. Binary logistic regression analysis was used to assess factors associated with increased risk of major bleeding. There were 2563 patients who underwent native renal biopsy (1499 elective, 1064 emergency). The average age of patients was 57 (SD 17) years and 57.4% were male. Overall, the rate of major bleeding was 2.2%. In all, 46 patients required transfusion (1.8%), 9 patients underwent embolization (0.4%), no patient required nephrectomy and 1 patient died as a result of a significant late retroperitoneal bleed. Major bleeding was more common in those undergoing emergency compared with elective renal biopsy (3.4 versus 1.1%; P 30). The risk of major bleeding following native renal biopsy in the modern era is low. Complications are more common when biopsy is conducted as an emergency, which has implications for obtaining informed consent. Our data support the strategy of not stopping aspirin before renal biopsy.

  7. Wildlife specimen collection, preservation, and shipment

    Science.gov (United States)

    White, C. LeAnn; Dusek, Robert J.; Franson, J. Christian; Friend, Milton; Gibbs, Samantha E.J.; Wild, Margaret A.

    2015-01-01

    Specimens are used to provide supporting information leading to the determination of the cause of disease or death in wildlife and for disease monitoring or surveillance. Commonly used specimens for wildlife disease investigations include intact carcasses, tissues from carcasses, euthanized or moribund animals, parasites, ingested food, feces, or environmental samples. Samples from live animals or the environment (e.g., contaminated feed) in the same vicinity as a mortality event also may be helpful. The type of specimen collected is determined by availability of samples and biological objectives. Multiple fresh, intact carcasses from affected species are the most useful in establishing a cause for a mortality event. Submission of entire carcasses allows observation of gross lesions and abnormalities, as well as disease testing of multiple tissues. Samples from live animals may be more appropriate when sick animals cannot be euthanized (e.g., threatened or endangered species) or for research and monitoring projects examining disease or agents circulating in apparently healthy animals or those not exhibiting clinical signs. Samples from live animals may include collections of blood, hair, feathers, feces, or ectoparasites, or samples obtained by swabbing lesions or orifices. Photographs and videos are useful additions for recording field and clinical signs and conveying conditions at the site. Collection of environmental samples (e.g., feces, water, feed, or soil) may be appropriate when animals cannot be captured for sampling or the disease agent may persist in the environment. If lethal collection is considered necessary, biologists should refer to the policies, procedures, and permit requirements of their institution/facility and the agency responsible for species management (U.S. Fish and Wildlife Service or State natural resource agency) prior to use in the field. If threatened or endangered species are found dead, or there is evidence of illegal take, field

  8. Tensile and Creep Testing of Sanicro 25 Using Miniature Specimens

    Science.gov (United States)

    Dymáček, Petr; Jarý, Milan; Dobeš, Ferdinand; Kloc, Luboš

    2018-01-01

    Tensile and creep properties of new austenitic steel Sanicro 25 at room temperature and operating temperature 700 °C were investigated by testing on miniature specimens. The results were correlated with testing on conventional specimens. Very good agreement of results was obtained, namely in yield and ultimate strength, as well as short-term creep properties. Although the creep rupture time was found to be systematically shorter and creep ductility lower in the miniature test, the minimum creep rates were comparable. The analysis of the fracture surfaces revealed similar ductile fracture morphology for both specimen geometries. One exception was found in a small area near the miniature specimen edge that was cut by electro discharge machining, where an influence of the steel fracture behavior at elevated temperature was identified. PMID:29337867

  9. Tensile and Creep Testing of Sanicro 25 Using Miniature Specimens.

    Science.gov (United States)

    Dymáček, Petr; Jarý, Milan; Dobeš, Ferdinand; Kloc, Luboš

    2018-01-16

    Tensile and creep properties of new austenitic steel Sanicro 25 at room temperature and operating temperature 700 °C were investigated by testing on miniature specimens. The results were correlated with testing on conventional specimens. Very good agreement of results was obtained, namely in yield and ultimate strength, as well as short-term creep properties. Although the creep rupture time was found to be systematically shorter and creep ductility lower in the miniature test, the minimum creep rates were comparable. The analysis of the fracture surfaces revealed similar ductile fracture morphology for both specimen geometries. One exception was found in a small area near the miniature specimen edge that was cut by electro discharge machining, where an influence of the steel fracture behavior at elevated temperature was identified.

  10. Tensile and Creep Testing of Sanicro 25 Using Miniature Specimens

    Directory of Open Access Journals (Sweden)

    Petr Dymáček

    2018-01-01

    Full Text Available Tensile and creep properties of new austenitic steel Sanicro 25 at room temperature and operating temperature 700 °C were investigated by testing on miniature specimens. The results were correlated with testing on conventional specimens. Very good agreement of results was obtained, namely in yield and ultimate strength, as well as short-term creep properties. Although the creep rupture time was found to be systematically shorter and creep ductility lower in the miniature test, the minimum creep rates were comparable. The analysis of the fracture surfaces revealed similar ductile fracture morphology for both specimen geometries. One exception was found in a small area near the miniature specimen edge that was cut by electro discharge machining, where an influence of the steel fracture behavior at elevated temperature was identified.

  11. Liver biopsy in patients on hemodialysis with hepatitis C virus infection: An important tool

    Directory of Open Access Journals (Sweden)

    S K Agarwal

    2015-01-01

    Full Text Available Hepatitis C virus (HCV infection is commonest blood borne infection amongst hemodialysis patients. Still, there is paucity of data on liver biopsy in these patients. Our center is doing regular liver biopsy in these patients and thus thought of sharing our experience. In this retrospective study, all patients with HCV infection on hemodialysis were subjected to liver biopsy. Serum bilirubin, liver enzyme, HCV-PCR, genotype and viral load measurement were done in all. Biopsy specimen was stained with H and E, Periodic Acid Schiff, Gomori Stain, Masson Trichrome and Perls Stain. International Working Group scoring system of Ishak et al. was used for Grading and Staging. Of the 270 liver biopsies, mean age of patients was 34.05 ΁ 10.28 years and 233 (85.3% were males. Mean duration of hemodialysis was 10.9 ΁ 7.4 months while of known HCV infection was 5.2 ΁ 4.0 months. Genotype 3 was commonest followed by 1. All had normal bilirubin and 64 (23.1% had normal ALT. In 37 (13.3% patients anti-HCV was not detectable. Mean histology grade was 4.03 ΁ 1.65 (1-10 and stage was 0.75 ΁ 0.98 (0-3. Only one patient had cirrhosis on histology. Associated hemosiderosis was seen 10 patients. Only minor complications were observed with no mortality. In conclusion, our study shows that in one-fourth patients with active liver disease, liver enzymes are persistently normal in patients on hemodialysis. Further, carefully performed liver biopsy is reasonably safe procedure though some patients do have non-fatal complications. Liver biopsy helps in assessing disease activity, which otherwise cannot be assessed. Histological grade and stage in these patients is usually mild and cirrhosis is rare. Till such time other non-invasive test is validated, liver biopsy will remain an important test in these patients.

  12. Skin and soft tissue infections: experience over a five-year period and clinical usefulness of ultrasonography-guided gun biopsy-based culture.

    Science.gov (United States)

    Noh, Ji Yun; Cheong, Hee Jin; Song, Joon Young; Hong, Suk-Joo; Myung, Jae Sung; Choi, Won Suk; Jo, Yu Mi; Heo, Jung Yeon; Kim, Woo Joo

    2011-12-01

    Skin and soft tissue infections (SSTIs) are common clinical diseases, but only a few reports of microbiological data on SSTIs in Korea have been published. In practice, specimens are rarely obtained from infected lesions unless there is visible pus or an abscess pocket. However, identification of the causative pathogen is important, because of emerging drug resistance and the increase in immunocompromised hosts. The medical records of 760 adult cases of community-acquired SSTIs (CA-SSTIs) from September 2003 to August 2008 were reviewed retrospectively. We analyzed epidemio-clinical features and microbiological distributions of CA-SSTIs and evaluated the positive culture rate of several diagnostic methods, including swab, tissue biopsy, blind needle aspiration, ultrasonography (US)-guided needle aspiration, and US-guided gun biopsy. Most CA-SSTIs (76.1%) occurred in previously healthy persons without underlying diseases. Re-infections were identified in 76 (10%) patients and cirrhosis was an independent risk factor for re-infection (odds ratio 3.64, 95% confidence interval 1.36-9.76). The most commonly identified pathogen was methicillin-susceptible Staphylococcus aureus, and 3(rd)-generation cephalosporins were the most commonly used empirical antibiotics (47.9%). US-guided needle aspiration had a high positive culture rate of 73.9% and the positive culture rate of US-guided gun biopsy was 17.5%. Considering the microbiological distribution of CA-SSTIs in Korea, penicillinase-stable penicillin or a 1(st)-generation cephalosporin should be adequate for initial antibiotic treatment. US-guided needle aspiration was a good technique for the identification of causative pathogens, and additive productivity is expected with US-guided gun biopsy culture from lesions without fluid collection.

  13. Imprint cytology on microcalcifications excised by Vacuum-Assisted Breast Biopsy: A rapid preliminary diagnosis

    Directory of Open Access Journals (Sweden)

    Drouveli Theodora

    2007-04-01

    Full Text Available Abstract Background To evaluate imprint cytology in the context of specimens with microcalcifications derived from Vacuum-Assisted Breast Biopsy (VABB. Patients and methods A total of 93 women with microcalcifications BI-RADS 3 and 4 underwent VABB and imprint samples were examined. VABB was performed on Fischer's table using 11-gauge Mammotome vacuum probes. A mammogram of the cores after the procedure confirmed the excision of microcalcifications. For the application of imprint cytology, the cores with microcalcifications confirmed by mammogram were gently rolled against glass microscope slides and thus imprint smears were made. For rapid preliminary diagnosis Diff-Quick stain, modified Papanicolaou stain and May Grunwald Giemsa were used. Afterwards, the core was dipped into a CytoRich Red Collection fluid for a few seconds in order to obtain samples with the use of the specimen wash. After the completion of cytological procedures, the core was prepared for routine histological study. The pathologist was blind to the preliminary cytological results. The cytological and pathological diagnoses were comparatively evaluated. Results According to the pathological examination, 73 lesions were benign, 15 lesions were carcinomas (12 ductal carcinomas in situ, 3 invasive ductal carcinomas, and 5 lesions were precursor: 3 cases of atypical ductal hyperplasia (ADH and 2 cases of lobular neoplasia (LN. The observed sensitivity and specificity of the cytological imprints for cancer were 100% (one-sided, 97.5% CI: 78.2%–100%. Only one case of ADH could be detected by imprint cytology. Neither of the two LN cases was detected by the imprints. The imprints were uninformative in 11 out of 93 cases (11.8%. There was no uninformative case among women with malignancy. Conclusion Imprint cytology provides a rapid, accurate preliminary diagnosis in a few minutes. This method might contribute to the diagnosis of early breast cancer and possibly attenuates

  14. PRELIMINARY EVALUATION OF SPIROTOME® DEVICE FOR LIVER BIOPSY IN GREEN IGUANAS (IGUANA IGUANA): A PILOT STUDY.

    Science.gov (United States)

    Nardini, Giordano; Origgi, Francesco C; Leopardi, Stefania; Zaghini, Anna; Saunders, Jimmy H; Vignoli, Massimo

    2016-06-01

    The aim of this study was to evaluate a large-core manual biopsy device (Spirotome(®), Medinvents, 3500 Hasselt, Belgium) for liver sampling and histologic diagnosis in green iguanas (Iguana iguana). The study included eight green iguanas, and two ultrasound-guided biopsies were collected for each lizard, for 16 biopsies in total. The procedure was carried out under general anesthesia induced by intravenous injection of propofol (10 mg/kg) maintained with a mixture of 2.0% isoflurane and 0.8-1.2 L/min oxygen after tracheal intubation. Fourteen (87.5%) of the 16 biopsies were considered diagnostic. Liver biopsy quality was assessed according to sample size and tissue preservation. In particular, mean length (16.2 ± 4.5 mm), width (2.2 ± 0.5 mm), area (34.8 ± 6.9 mm(2)), and number of portal areas (9.4 ± 3.9) of each biopsy were recorded for all green iguanas. The total available surface of the sections obtained from the biopsies and their grade of preservation enabled a satisfactory evaluation of the parenchymal architecture. One of the green iguanas in the study died the day after the procedure due to severe hemocoeloma. Risk assessment evaluation suggested that small green iguanas may not be suitable for this biopsy procedure.

  15. Upright stereotactic vacuum-assisted needle biopsy of suspicious breast microcalcification

    International Nuclear Information System (INIS)

    Sim, L. S. J.; Kei, P. L.

    2008-01-01

    Full text: Stereotactic core needle biopsy is a useful technique for evaluation of suspicious breast microcalcifications. Thf development of the 11-G vacuum-assisted biopsy system offers another method of minimally invasive biopsy carried out on a conventional mammography unit. We evaluate its usefulness, efficacy and safety in Asian women.. Vacuum-assisted biopsy was carried out through the lateral approach using an add-on stereotactic device attached to a mammography unit. One hundred and five lesions were sampled in 97 patients. Excisional biopsy was subsequently Carried out for diagnosis of atypical ductal hyperplasia or carcinoma in high-risk patients. Patients with benign diagnosis underwent mammographic follow up. The technical success rate was 97%. An average of 13.5 tissue cores were retrieved for each lesion. The histopathological result obtained from mammotome was benign in 84.8% and malignant in 15.2%. The benign microcalcifications were predominantly fibrocystic change (n = 42)| whereas the malignant microcalcifications included ductal carcinoma in situ (n = 15) and invasive carcinoma (n = 1). Twenty-two patients underwent subsequent open surgical biopsy but no underestimation of disease was seen. Only two patients had vasovagal syncope and three others felt unwell during the biopsy. Nine patients had small haema-1 tomas, which resolved spontaneously. Vacuum-assisted biopsy carried out on an upright stereotactic mammography] unit is a safe and effective method for evaluation of suspicious microcalcifications.

  16. Improving CT-guided transthoracic biopsy of mediastinal lesions by diffusion-weighted magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Guimaraes, Marcos Duarte; TyngI, Chiang Cheng; Bitencourt, Almir Galvao Vieira; Gross, Jefferson Luiz; Zurstrassen, Charles Edouard, E-mail: marcosduarte500@gmail.com [AC Camargo Cancer Center, Sao Paulo, SP (Brazil); Hochhegger, Bruno [Universidade Federal de Ciencias da Saude de Porto Alegre (UFCSPA), RS (Brazil). Dept. de Radiologia; Benveniste, Marcelo Felipe Kuperman; Odisio, Bruno Calazans [University of Texas, MD Anderson Cancer Center, Houston, TX (United States); Marchiori, Edson [Universidade Federal do Rio de Janeiro (UFRJ), Petropolis, RJ (Brazil)

    2014-11-15

    Objectives: to evaluate the preliminary results obtained using diffusion-weighted magnetic resonance imaging and the apparent diffusion coefficient for planning computed tomography-guided biopsies of selected mediastinal lesions. Methods: eight patients with mediastinal lesions suspicious for malignancy were referred for computed tomography-guided biopsy. Diffusion-weighted magnetic resonance imaging and apparent diffusion coefficient measurement were performed to assist in biopsy planning with diffusion/computed tomography fused images. We selected mediastinal lesions that could provide discordant diagnoses depending on the biopsy site, including large heterogeneous masses, lesions associated with lung atelectasis or consolidation, lesions involving large mediastinal vessels and lesions for which the results of biopsy using other methods and histopathological examination were divergent from the clinical and radiological suspicion. Results: in all cases, the biopsy needle was successfully directed to areas of higher signal intensity on diffusion weighted sequences and the lowest apparent diffusion coefficient within the lesion (mean, 0.8 [range, 0.6–1.1]610{sup -3} mm{sup 2}/s), suggesting high cellularity. All biopsies provided adequate material for specific histopathological diagnoses of four lymphomas, two sarcomas and two thymoma s. Conclusion: functional imaging tools, such as diffusion-weighted imaging and the apparent diffusion coefficient, are promising for implementation in noninvasive and imaging-guided procedures. However, additional studies are needed to confirm that mediastinal biopsy can be improved with these techniques. (author)

  17. Fluoroscopically guided automated gun biopsy of chest lesions: diagnostic accuracy and complications

    International Nuclear Information System (INIS)

    Oh, Hee Sul; Han, Young Min; Choi, Ki Chul and others

    1998-01-01

    To determine the diagnostic accuracy and frequency of complications of fluoroscopyguided transthoracic needle biopsy, using an automated gun biopsy system. We retrospectively reviewed 86 patients who underwent automated gun biopsy between October 1995 and October 1996. An 18-gauge cutting needle was used in all cases. All biopsies were performed under fluoroscopic guidance by one interventional radiologist. Tissue sufficient for histologic diagnosis was obtained in 73 of 86 biopsies(84.9%). Fifty-six lesions were malignent and 30 were benign. Sensitivity and diagnostic accuracy for malignant lesions were 87.5% and 87.5%, respectively while cell type specificity in malignant diagnosis was 91.7%(11/12). Sensitivity and diagnostic accuracy for benign lesions were 80.0% and 73.3%, respectively. Postbioptic pneumothorax occurred in three of 86 biopsies(3.5%), one of which required placement of a chest tube. Automated gun biopsy is a simple, safe method for the diagnosis of focal chest lesions. An automated biopsy device offers high diagnostic accuracy in casis involving malignant and benign lesions of the chest, and is particularly useful for determining malignant cell type and specific diagnosis of benign lesions.=20

  18. A new surgical localization technique for biopsy in patients with nipple discharge.

    Science.gov (United States)

    Choudhury, A; Wengert, P A; Smith, J S

    1989-07-01

    In a series of 12 patients with bloody nipple discharge, a new technique of mammary ductal localization was used to identify the duct responsible for the discharge and assure its complete removal for pathological diagnosis. This procedure utilizes a 30-gauge anterior chamber needle that is gently advanced into the offending duct, and methylene blue dye is injected to outline the involved duct for easy dissection though a circumareolar incision. This provides the pathologist with an intact specimen and avoids the problems associated with specimen roentgenography or loss of a ductal probe during the procedure. Because we feel that all patients with a bloody nipple discharge warrant a biopsy, this procedure provides a safe, rapid, effective method and allows the biopsy to be done on an outpatient basis.

  19. Improvement and optimization of the classical gastric biopsy culture technique for Helicobacter pylori diagnosis using trypsin.

    Science.gov (United States)

    Peretz, Avi; Paritsky, Maya; Pastukh, Nina; Koifman, Anna; Brodsky, Diana; Glyatman, Tatyana; On, Avi

    2015-06-01

    Helicobacter pylori infection represents a key factor in the aetiology of various gastrointestinal diseases. H. pylori infection diagnosis is generally achieved using both invasive (e.g. biopsy of the gastric epithelium) and non-invasive methods. Therefore, cultivation on a growth medium becomes complex. Trypsin is a proteinase enzyme that plays a role in an early stage of tissue digestion. In this study, we used trypsin in order to improve the diagnostic sensitivity of the H. pylori cultivation technique. We used 46 duplicate antrum biopsy specimens, divided into trypsin-treated and non-treated groups. The tissues were seeded on a selective H. pylori growth agar medium. We demonstrated that the classic H. pylori culture technique misses the growth of a large number of H. pylori colonies. Significantly more colonies were found in the trypsin-treated specimens group.

  20. Innovation for reducing blood culture contamination: initial specimen diversion technique.

    Science.gov (United States)

    Patton, Richard G; Schmitt, Timothy

    2010-12-01

    We hypothesized that diversion of the first milliliter of venipuncture blood-the initial specimen diversion technique (ISDT)-would eliminate incompletely sterilized fragments of skin from the culture specimen and significantly reduce our blood culture contamination rate (R). We studied our hypothesis prospectively beginning with our control culture (C) definition: one venipuncture with two sequentially obtained specimens, 10 ml each, the first specimen (M1) for aerobic and the second (M2) for anaerobic media. The test ISDT culture (D) was identical, with the exception that each was preceded by diverting a 1-ml sample (DS) from the same venipuncture. During the first of two sequential 9-month periods, we captured D versus C data (n=3,733), where DMXR and CMXR are R for D and C specimens. Our hypothesis predicted DS would divert soiled skin fragments from DM1, and therefore, CM1R would be significantly greater than DM1R. This was confirmed by CM1R (30/1,061 [2.8%]) less DM1R (37/2,672 [1.4%]; P=0.005), which equals 1.4%. For the second 9-month follow-up period, data were compiled for all cultures (n=4,143), where ADMXR is R for all (A) diversion specimens, enabling comparison to test ISDT. Our hypothesis predicted no significant differences for test ISDT versus all ISDT. This was confirmed by DM1R (37/2,672 [1.4%]) versus ADM1R (42/4,143 [1.0%]; P=0.17) and DM2R (21/2,672 [0.80%]) versus ADM2R (39/4,143 [0.94%]; P=0.50). We conclude that our hypothesis is valid: venipuncture needles soil blood culture specimens with unsterilized skin fragments and increase R, and ISDT significantly reduces R from venipuncture-obtained blood culture specimens.

  1. Plugged percutaneous biopsy of the liver in living-donor liver transplantation recipients suspected to have graft rejection.

    Science.gov (United States)

    Kim, Sung Jung; Won, Je Hwan; Kim, Young Bae; Wang, Hee-Jung; Kim, Bong-Wan; Kim, Haeryoung; Kim, Jinoo

    2017-07-01

    Background Percutaneous biopsy is a widely-accepted technique for acquiring histologic samples of the liver. When there is concern for bleeding, plugged percutaneous biopsy (PPB) may be performed, which involves embolization of the biopsy tract. Purpose To evaluate the efficacy and safety of PPB of the liver in patients suspected to have graft rejection after living-donor liver transplantation (LDLT). Material and Methods During January 2007 and December 2013, 51 patients who underwent PPB of the liver under the suspicion of post-LDLT graft rejection were retrospectively analyzed. A total of 73 biopsies were performed. Biopsy was performed with a 17-gauge core needle and 18-gauge cutting needle. The needle tract was embolized using gelatin sponge (n = 44) or N-butyl cyanoacrylate (NBCA) (n = 29). The specimens were reviewed to determine their adequacy for histologic diagnosis. We reviewed all medical records after PPB. Results Specimens were successfully acquired in all procedures (100%). They were adequate for diagnosis in 70 cases (95.9%) and inadequate in three (1.3%). Average of 9.8 complete portal tracts was counted per specimen. One minor complication (1.4%) occurred where the patient had transient fever after the procedure. Conclusion PPB is easy and safe to perform in LDLT recipients and provides high diagnostic yield.

  2. Biopsy of human morula-stage embryos: outcome of 215 IVF/ICSI cycles with PGS.

    Directory of Open Access Journals (Sweden)

    Elena E Zakharova

    Full Text Available Preimplantation genetic diagnosis (PGD is commonly performed on biopsies from 6-8-cell-stage embryos or blastocyst trophectoderm obtained on day 3 or 5, respectively. Day 4 human embryos at the morula stage were successfully biopsied. Biopsy was performed on 709 morulae from 215 ICSI cycles with preimplantation genetic screening (PGS, and 3-7 cells were obtained from each embryo. The most common vital aneuploidies (chromosomes X/Y, 21 were screened by fluorescence in situ hybridization (FISH. No aneuploidy was observed in 72.7% of embryos, 91% of those developed to blastocysts. Embryos were transferred on days 5-6. Clinical pregnancy was obtained in 32.8% of cases, and 60 babies were born. Patients who underwent ICSI/PGS treatment were compared with those who underwent standard ICSI treatment by examining the percentage of blastocysts, pregnancy rate, gestational length, birth height and weight. No significant differences in these parameters were observed between the groups. Day 4 biopsy procedure does not adversely affect embryo development in vitro or in vivo. The increased number of cells obtained by biopsy of morulae might facilitate diagnostic screening. There is enough time after biopsy to obtain PGD results for embryo transfer on day 5-6 in the current IVF cycle.

  3. BONE MARROW BIOPSY IN EVALUATION OF HAEMATOLOGICAL DISORDERS

    Directory of Open Access Journals (Sweden)

    Sandhya Rani Sahoo

    2017-04-01

    Full Text Available BACKGROUND Bone Marrow Trephine Biopsy (BMTB and aspiration is critical for diagnosis, prognostic evaluation and monitoring therapeutic response. BMTB is of greater value in assessing cellularity, degree of fibrosis, marrow architecture and especially when aspiration is dry tap. At the same time, it provides sample for immunohistochemistry. MATERIALSAND METHODS It is a single centre observational study conducted from July 2014 to July 2016 in Department of Pathology, S.C.B. Medical College, Cuttack, which included both cell block and touch imprint along with trephine biopsy. Cases selected where lymphoma studied for pattern and extent of infiltration. Aspiration with dry tap and selected cases of myeloproliferative disorders, myelodysplastic syndrome, leukaemia (both acute and chronic, anaemia, multiple myeloma were studied. Jamshidi needle was used for biopsy. Samples obtained were formalin preserved, kept in decalcification solution (Hammersmith protocol and H and E slides prepared. Special stain-like reticulin and Masson’s trichrome were used for grading of fibrosis. Immunohistochemistry was done on selected cases of lymphoma. RESULTS Out of total 100 cases studied, 60 were of haematopoietic and lymphoid neoplasms, 12 anaemia, 20 secondary metastasis, 8 miscellaneous (1 haemophagocytic lymphohistiocytic disease, 1 storage disease, 1 granulomatous and 5 ITP. CONCLUSION The study was conducted to establish the advantage of bone marrow biopsy in inadequate and failed aspiration, but both are complementary to each other and together provide a comprehensive evaluation of the bone marrow. Bone marrow fibrosis are well accessed and increased detection of tumour cells in suspected secondary metastasis. Special stains, IHC, cytogenetic study can be done over biopsy block.

  4. CT-guided core biopsy of malignant lung lesions: how many needle passes are needed?

    International Nuclear Information System (INIS)

    Lim, Chaehun; Han, Dae Hee; Lee, Kyo Young; Kim, Young Kyoon; Ko, Jeong Min

    2013-01-01

    The study aims to determine the number of needle pass in the CT-guided core needle biopsy (CNB) in making a diagnosis of pulmonary malignancy. A total of 434 CNB records were retrospectively reviewed. The specimen obtained from each needle pass was put in a formalin container and then labelled for separate histopathological reporting. The patients were divided into five groups according to the total number of needle passes (n=1, n=2, n=3, n=4 and n≥5). In each of the groups 2–4, it was analysed how many needle passes are required before a plateau in diagnostic yield is achieved. CNB produced 283 true-positive and 23 false-negative diagnosis of malignancy. Cumulative sensitivity significantly (P<0.05) increased between the first and second as well as the second and the third (if done) needle passes, but not between the third and fourth ones. Three coaxial needle passes might be optimal in the diagnosis of lung malignancy.

  5. Prevention of sepsis prior to prostate biopsy

    Directory of Open Access Journals (Sweden)

    Liam Toner

    2016-03-01

    Full Text Available Purpose: Urosepsis is the most feared complication of transrectal prostate biopsy. The incidence may be increasing from <1% to 2%–3% in contemporary series. Historically, fluoroquinolones have been effective antibiotic prophylaxis to prevent infective complications but antibiotic resistance is increasing. The increase in antibiotic resistance may contribute to reported increases in urosepsis and hospitalization after transrectal biopsy. This article will review other methods clinicians may employ to reduce the incidence of infective complications after prostate biopsy. Materials and Methods: A systematic review of the literature was conducted using literature databases PubMed and Ovid MEDLINE in August 2015 in accordance with the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-analyses criteria. Results: Effective strategies to reduce infective complications after transrectal prostate biopsy include augmented prophylaxis with other antibiotics, rectal swab culture directed antibiotic prophylaxis or a transperineal biopsy approach. Needle disinfection, minimizing the number of biopsy needles and rectal disinfectants may also be of use. These methods may be of particular utility in patients with risk factors for developing urosepsis such as recent antibiotic use and overseas travel. Conclusions: The scientific literature describes various techniques designed to reduce infective complications caused by prostate biopsy. Clinicians should consider incorporating these novel techniques into their contemporary practice.

  6. The percentage of affected fragments in needle biopsy in the assessment of pathological staging of prostate cancer

    Directory of Open Access Journals (Sweden)

    Rógerson Tenorio de Andrade

    2013-10-01

    Full Text Available INTRODUCTION: Prostate cancer has high prevalence and mortality among men. Some of the findings on prostate biopsy may be related to the prognosis of the disease. OBJECTIVE: To evaluate the association between the percentage of fragments affected by cancer in the prostate biopsy and the pathological staging in the surgical specimen. MATERIALS AND METHODS: Selected 159 patients underwent radical prostatectomy (RP between 2003 and 2009. Data was collected on age, digital rectal exam, prostate-specific antigen (PSA, Gleason score, number of biopsy fragments, number of fragments affected by tumor, and tumor extension in the surgical specimen. Statistical analysis with Student's t-test, chi-squared test, and multiple logistic regression evaluated the association of percentage of affected fragments (PAF with tumor extension and its predictive value. RESULTS: The patients mean age and PSA were respectively 64 years and 8.5 ng/ml. Histopathologic evaluation of surgical specimens revealed 20.8% of patients with extraprostatic disease, 8.2% with seminal vesicle invasion and 35.8% with positive margins. We found that patients with extraprostatic disease, positive surgical margins, and seminal vesicle invasion had a higher mean PAF. PAF was divided into three groups: less than 34%, 34% to 50%, and greater than 50%, and the higher the PFA, the larger the increase in pathological changes. CONCLUSION: PAF in biopsy is a simple and practical parameter, which should be used as a predictor of pathological stage in RP specimen.

  7. Measurements and Counts for Notacanthidae Specimens

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Taxonomic data were collected for specimens of deep-sea spiny eels (Notacanthidae) from the Hawaiian Ridge by Bruce C. Mundy. Specimens were collected off the north...

  8. Transjugular liver core biopsy: indications, results, and complications

    International Nuclear Information System (INIS)

    Dinkel, H.P.; Wittchen, K.; Hoppe, H.; Triller, J.; Dufour, J.F.; Zimmermann, A.

    2003-01-01

    Purpose: To evaluate benefit, feasibility, and frequency of complications with transjugular liver biopsy using a semi-automatic Tru-cut system. Materials and Methods: Eighty-five consecutive patients (57 males, 28 females) with various liver disorders (cirrhosis [30], hepatitis [12], acute hepatopathy [34], orthotopic liver transplantation [8], hepatocellular carcinoma [1]), coagulopathies (n=71) and/or ascites (n = 46) were referred to our department for a transjugular liver biopsy. Mean age was 48 ± 16 years (range 17 to 75 years). Success and complications were retrospectively evaluated from the radiology reports, pathology reports, and patient files. Success was defined as procuring a tissue specimen that enabled a definite histological diagnosis. The complications included thrombosis at the puncture site, hematoma, cardiac arrhythmia, capsular perforation, hemorrhage, and cardiac damage. Mortality included all deaths within 30 days after the procedure. Procedure-related mortality included all deaths related to the procedure. Results: The procedure was technically successful in 80 patients (94%) and unsuccessful in 5 patients (6%) due to a failed hepatic vein cannulation (1 patient with Budd Chiari syndrome and total liver vein occlusion, 4 patients with unsuitable anatomy). One biopsy pass was made in 22 patients, and two passes were made in 45 and three or more passes in 14 patients, all in a single session. The sample quality was judged by the pathologist as good in 71 of 80 patients (89%) and poor in 8 patients (10%). A diagnosis was not possible in 1 patient. Eight procedure-related complications occurred, which were classified according to the criteria of the society of interventional radiology (SIR) as minor in 5 (3 type A, 2 type B) and major in 3 (1 pneumothorax, type C, 1 nonfatal bleeding, type D, and 1 fatal bleeding, type F). Procedure-related mortality was 1%, overall mortality 15% (mostly due to progressive liver failure). (orig.) [de

  9. [Is percutaneous liver biopsy using the Trucut (Travenol) needle superior to Menghini puncture?].

    Science.gov (United States)

    Judmaier, G; Prior, C; Klimpfinger, M; Bernklau, E; Vogel, W; Dietze, O; Denk, H

    1989-11-01

    The aim of this study was to compare the quality of biopsy cylinders obtained by the Menghini or Trucut liver biopsy-method as well as the frequency of complications observed with both these methods. For this purpose, 74 Menghini and 62 Trucut biopsies were analyzed. Both groups were comparable with respect to histologic diagnosis, but no final diagnosis could be made in eight cases of Menghini biopsy because of insufficiency of the material obtained. Fragmentation of the sample occurred significantly more often in the Menghini group (p less than 0.05; chi 2 test). Trucut biopsies were significantly longer (12 mm versus 8 mm mean value; p less than 0.001; Wilcoxon rank sum test) and contained significantly more portal tracts (16 versus 6 mean value; p less than 0.001). None of the total 136 biopsies led to serious complications. We conclude that Trucut liver biopsy is superior to the Menghini method since tissue yield is better and both methods are equally safe.

  10. Ultrasound-guided biopsy of transplanted pancreas: evaluation of 20 cases

    Directory of Open Access Journals (Sweden)

    Marcel Vieira da Nóbrega

    2009-03-01

    Full Text Available Objective: To report the experience with percutaneous biopsies of pancreatic grafts guided by ultrasonography. Methods: Series of cases referred from outpatient’s clinic for biopsy of pancreas transplant, between December 2006 and March 2008. Data were collected from medical electronic records for age, sex and histopathology. The indication for the procedure was obtained from medical and laboratory records. Doppler ultrasonography was performed for control and to guide biopsy in real time. Rresults: Twenty patients referred for biopsy of their transplanted pancreas over a one-year period were evaluated. In one patient, biopsy was not performed for having no safe access for ultrasound. It was used 18 gauge needles, mostly automatic-cut type. The main indications were increased blood glucose and pancreatic enzyme levels as well as reduction of urinary amylase. The sonographic aspect of the pancreatic graft was normal in 18 cases. In all 19 biopsies performed, satisfactory samples for histopathological study were obtained. There were no complications. Cconclusions: This series of cases demonstrated low sensitivity and specificity of ultrasound in diagnosis of pancreatic transplants disorders, but showed to be very useful to guide transplanted pancreas biopsies. Although no complications occurred in this experience, the risk-benefit relation should always be assessed for every patient.

  11. Effect of a Biopsy Center on Adequacy Rates of Thyroid Nodule Fine-Needle Aspiration.

    Science.gov (United States)

    Leung, Vincent A; Kirpalani, Anish; Mnatzakanian, Gevork; Colak, Errol; Vlachou, Paraskevi A

    2017-08-01

    The purpose of this study was to investigate the effect of a biopsy center-a dedicated space with a dedicated ultrasound machine and technologist, staffed daily by a radiologist responsible for performing ultrasound-guided procedures only-on the rate of non-diagnostic or unsatisfactory thyroid fine-needle aspiration (FNA). Three radiologists performed FNA on 1200 nodules in 998 patients between September 2010 and November 2015. We compared rates of nondiagnostic or unsatisfactory FNA before and after implementation of a biopsy center in September 2014 as part of a quality improvement initiative. Before the establishment of our biopsy center, ultrasound-guided procedures were scheduled between diagnostic studies in the main ultrasound department and were performed by a radiologist responsible for both. Multivariate logistic regression analysis was performed to assess the effect of the biopsy center on the odds of obtaining an adequate sample. Rates of nondiagnostic or unsatisfactory FNA decreased significantly from 15.1% to 8.5% (p < 0.001) after implementation of the biopsy center. The odds of obtaining an adequate sample were higher in the biopsy center (odds ratio, 2.07; 95% CI, 1.43-3.01), even after adjusting for patient age, nodule size, the radiologist performing the procedure, and time over the study period. The implementation of a biopsy center was associated with significantly lower rates of nondiagnostic or unsatisfactory thyroid FNA, suggesting target rates of 10% or lower are achievable with quality improvement measures.

  12. Sono-Guided Percutaneous Automated Gun Biopsy in Pediatric Renal Disease

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jong Chul [Chungnam National University College of Medicine, Daejeon (Korea, Republic of)

    1996-12-15

    To evaluate whether sono-guided percutaneous automated gun biopsy is also useful in pediatricpatients with renal diseases. In the prone position of twenty pediatric patients with renal parenchymal diseases, percutaneous biopsy was done through lateral aspect of the lower pole of left kidney with automated biopsy gun under the guidance of ultrasonography. The biopsy needle was either of 18 or 20 gauge. The obtained core of renal tissue was examined with light, immunofluorescent or electron microscope by the renal pathologist. In 18 among 20 patients, adequate renal tissue core sufficient to be pathologically diagnosed was obtained. The histologic findings were as follows : IG A nephropathy (n = 2), lupus nephritis (n =2), minimal change glomerulonephritis (n = 5), membranoproliferative glomerulonephritis (n = 3), mesangialproliferative glomeru-lonephritis (n = 1), diffuse proliferative glomerulonephritis (n = 3), focalglomerulo-sclerosis (n = 1), membranous glomerulopathy (n = 1). No significant complications occurred during or after the biopsy. Sono-guided percutaneous renal biopsy using automated biopsy gun is also useful todiagnose renal parenchymal diseases without significant complications in pediatric patients

  13. Techniques for the recovery and identification of Cryptosporidium oocysts from stool specimens.

    OpenAIRE

    Garcia, L S; Bruckner, D A; Brewer, T C; Shimizu, R Y

    1983-01-01

    Due to increasing numbers of patients with documented infections with Cryptosporidium and other coccidia, it is important for the physician and clinical laboratory to be aware of the appropriate diagnostic techniques necessary for organism recovery and identification. Although Cryptosporidium is found in the gastrointestinal tract, tissue biopsies may be insufficient for organism recovery; the examination of stool specimens is a noninvasive procedure and will provide better overall opportunit...

  14. Detection of the microsporidian parasite Enterocytozoon bieneusi in specimens from patients with AIDS by PCR.

    OpenAIRE

    Velásquez, J N; Carnevale, S; Guarnera, E A; Labbé, J H; Chertcoff, A; Cabrera, M G; Rodríguez, M I

    1996-01-01

    Microsporidia are protozoa parasites responsible for significant gastrointestinal disease in patients infected with human immunodeficiency virus. We evaluated a PCR assay of stool samples, duodenal aspirates, and biopsy specimens from patients with Enterocytozoon bieneusi infection. A 210-bp DNA fragment of the unique rRNA intergenic spacer could be amplified from all samples infected with E. bieneusi, but no amplification was seen by using DNA purified from samples with Septata intestinalis ...

  15. Study of two tantalum Taylor impact specimens using experiments and stochastic polycrystal plasticity simulation

    Energy Technology Data Exchange (ETDEWEB)

    Tonks, Michael R [Los Alamos National Laboratory

    2008-01-01

    We compare the experimentally obtained response of two cylindrical tantalum Taylor impact specimens. The first specimen is manufactured using a powder metallurgy (P/M) process with a random initial texture and relatively equiaxed crystals. The second is sectioned from a roundcorner square rolled (RCSR) rod with an asymmetric texture and elongated crystals. The deformed P/M specimen has an axisymmetric footprint while the deformed RCSR projectile has an eccentric footprint with distinct corners. Also, the two specimens experienced similar crystallographic texture evolution, though the RCSR specimen experienced greater plastic deformation. Our simulation predictions mimic the texture and deformation data measured from the P/M specimen. However, our RCSR specimen simulations over-predict the texture development and do not accurately predict the deformation, though the deformation prediction is improved when the texture is not allowed to evolve. We attribute this discrepancy to the elongated crystal morphology in the RCSR specimen which is not represented in our mean-field model.

  16. Ultrasound guided pleural biopsy in undiagnosed exudative pleural effusion patients

    Directory of Open Access Journals (Sweden)

    Adel S. Ahmed

    2016-04-01

    In conclusion: Thoracic ultrasound (TUS guided pleural biopsy had a diagnostic yield which was slightly lower but comparable to both CT guided pleural biopsy and medical thoracoscopic pleural biopsy (MT.

  17. Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid

    Science.gov (United States)

    ... Physician Resources Professions Site Index A-Z Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid An ... Aspiration Biopsy of the Thyroid? What is Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid? During ...

  18. Life-threatening complication of percutaneous transthoracic fine-needle aspiration biopsy: systemic arterial air embolism.

    Science.gov (United States)

    Olgun, Deniz Cebi; Samanci, Cesur; Ergin, Ayse Seda; Akman, Canan

    2015-02-01

    Computed tomography-guided percutaneous transthoracic fine-needle aspiration biopsy of lung lesions is a well known diagnostic technique. Nevertheless, it has some complications; such as pneumothorax, intraparenchymal hemorrhage and hemoptysis, which are not rare. Air embolism is one of the rare but potentially fetal complications of this procedure. Herein, we report the case of a 69-year-old male, in which case of systemic air embolism developed after the performance of lung biopsy. Early diagnosis and prompt oxygen therapy is crucial for patient's survival so careful reviewing of the obtained computed tomography images during the biopsy may prevent a missing systemic air embolism and provide an adequate therapy.

  19. Stereotactic biopsy aided by a computer graphics workstation: experience with 200 consecutive cases.

    Science.gov (United States)

    Ulm, A J; Bova, F J; Friedman, W A

    2001-12-01

    The advent of modern computer technology has made it possible to examine not just the target point, but the entire trajectory in planning for stereotactic biopsies. Two hundred consecutive biopsies were performed by one surgeon, utilizing a computer graphics workstation. The target point, entry point, and complete trajectory were carefully scrutinized and adjusted to minimize potential complications. Pathologically abnormal tissue was obtained in 197 cases (98.5%). There was no mortality in this series. Symptomatic hemorrhages occurred in 4 cases (2%). Computer graphics workstations facilitate safe and effective biopsies in virtually any brain area.

  20. Circulating tumor DNA detection (liquid biopsy: prospects in oncology

    Directory of Open Access Journals (Sweden)

    N. V. Zhukov

    2015-01-01

    Full Text Available Modern research techniques allows tumor studying in almost any level: protein expression, structural changes of DNA, RNA, epigenetic changes, activity of signaling pathways, microenvironment, interaction with the immune system, etc. However, tumor samples are obtained as 100 years ago – by tumor biopsy prior to treatment. Based on available data about intratumoral heterogeneity and tumor changes during treatment, it may be one of the factors braking to obtain required information of tumor biology. According to study, the analysis of circulating tumor DNA (ctDNA allows to hope to overcome the key limitations of routine biopsy. One of the key benefits of ctDNA analysis is the ability to a more comprehensive tumor investigation, while maintain