WorldWideScience

Sample records for biopsy results showed

  1. Radiologically Guided Bone Biopsy: Results of 502 Biopsies

    International Nuclear Information System (INIS)

    Ng, Chaan S.; Salisbury, Jonathan R.; Darby, Alan J.; Gishen, Philip

    1998-01-01

    Purpose: To analyze the results of 502 biopsies over a 19-year period for the purpose of highlighting the results that can be expected from such a large study, with emphasis on needle choice and anesthetic methods. Methods: The histological, cytological, and microbiological results of 477 patients who had 502 bone biopsies carried out between July 1977 and March 1996 were studied. Less than 5% of patients required second biopsies. There were almost equal numbers of males and females in the group. The lesions were visible radiologically and most of the biopsies were carried out by a single operator. The lesions were classified on their histopathological, cytopathological, and microbiological findings. Results: Tumors accounted for 40% of the biopsies, and infection for 16%. Biopsies which did not yield a 'positive' diagnosis accounted for 31%; these included specimens reported as normal, or as showing reactive changes, repair, remodelling, non-specific features, inflammation (but not clearly infective), or no evidence of malignancy or inflammation. Less than 4% of biopsies were incorrect, and some of these were re-biopsied. Conclusion: Bone biopsy is a valuable technique for positive diagnosis of malignancy or infection, as it enables a definitive plan for treatment and management of patients to be established. Exclusion of serious pathology is almost equally important. In principle, any osseous site can be biopsied using fluoroscopic or computed tomographic guidance. Care in the biopsy technique and selection of the bone needle is required

  2. Ultrastructural examination of skin biopsies may assist in diagnosing mitochondrial cytopathy when muscle biopsies yield negative results.

    Science.gov (United States)

    McAfee, John L; Warren, Christine B; Prayson, Richard A

    2017-08-01

    Ultrastructural evaluation of skin biopsies has been utilized for diagnosis of mitochondrial disease. This study investigates how frequently skin biopsies reveal mitochondrial abnormalities, correlates skin and muscle biopsy findings, and describes clinical diagnoses rendered following the evaluation. A retrospective review of surgical pathology reports from 1990 to 2015 identified skin biopsies examined by electron microscopy for suspected metabolic disease. A total of 630 biopsies were included from 615 patients. Of these patients, 178 also underwent a muscle biopsy. Of the 630 skin biopsies, 75 (12%) showed ultrastructural abnormalities and 34 (5%) specifically showed mitochondrial abnormalities including increased size (n=27), reduced or abnormal cristae (n=23), dense matrices (n=20), and increased number (n=8). Additional findings included lysosomal abnormalities (n=13), lipid accumulation (n=2) or glycogen accumulation (n=1). Of the 34 patients with mitochondrial abnormalities on skin biopsy, 20 also had muscle biopsies performed and nine showed abnormalities suggestive of a mitochondrial disorder including absent cytochrome oxidase staining (n=2), increased subsarcolemmal NADH, SDH, or cytochrome oxidase staining (n=1), or ultrastructural findings including large mitochondrial size (n=5), abnormal mitochondrial structure (n=5), and increased mitochondrial number (n=4). The most common presenting symptoms were intellectual disability (n=13), seizures (n=12), encephalopathy (n=9), and gastrointestinal disturbances (n=9). At last known follow-up, 12 patients had a definitive diagnosis of a mitochondrial disorder. One patient each had Complex I deficiency, Complex III deficiency, Charcot-Marie-Tooth disease, pyruvate dehydrogenase deficiency, and Phelan-McDermid syndrome. Our results suggest that skin biopsy sometimes yields diagnostic clues suggestive of a mitochondrial cytopathy in cases with a negative muscle biopsy. Copyright © 2017 Elsevier Inc. All rights

  3. Punch Biopsy Results in Misdiagnosis of Pilomatrixoma

    Directory of Open Access Journals (Sweden)

    Metin Temel

    2017-03-01

    Full Text Available Punch biopsy results in misdiagnosis of clinically unsuspected giant pilomatrixoma located over the parotid gland. This study presents a case of pilomatrixoma that was misdiagnosed as a malignant epithelial tumor using punch biopsy. A 25-year-old male was admitted to our clinic for the evaluation of a mass measuring 7×8×8 cm located over the parotid gland. The patient had previously undergone punch biopsy at another clinic because of a lesion in the parotid gland. Punch biopsy revealed a malignant epithelial tumor. The patient underwent excisional biopsy at our clinic. After the biopsy, the residual skin defect was treated using full-thickness skin grafts. The facial nerve and parotid gland were preserved during the biopsy. Histopathological examination of the excisional biopsy material revealed pilomatrixoma. Punch biopsy may result in misdiagnosis of skin lesions in the parotid gland. A differential diagnosis for benign tumors such as pilomatrixoma is essential prior to an aggressive surgical intervention of the parotid gland.

  4. False-negative results of breast core needle biopsies - retrospective analysis of 988 biopsies

    International Nuclear Information System (INIS)

    Boba, M.; Koltun, U.; Bobek-Billewicz, B.; Eksner, B.; Olejnik, T.; Chmielik, E.

    2011-01-01

    Background: Breast cancer is the most common malignant neoplasm and the most common cause of death among women. The core needle biopsy is becoming a universal practice in diagnosing breast lesions suspected of malignancy. Unfortunately, breast core needle biopsies also bear the risk of having false-negative results. Material/Methods: 988 core needle breast biopsies were performed at the Maria Sklodowska-Curie Memorial Cancer Center and Institute of Oncology, Gliwice Branch, between 01 March 2006 and 29 February 2008. Malignant lesions were diagnosed in 426/988 (43.12%) cases, atypical hyperplasia in 69/988 (6.98%), and benign lesions in 493/988 (49.90%) cases. Results: Twenty-two out of 988 biopsies (2.23%) were found to be false negative. Histopathological assessment of tissue specimens was repeated in these cases. In 14/22 (64%) cases, the previous diagnosis of a benign lesion was changed. In 8/22 (36%) cases, the diagnosis of a benign lesion was confirmed. False-negative rate was calculated at 2.2%. The rate of false-negative diagnoses resulting from a radiological mistake was estimated at 36%. The rate of false-negative diagnoses, resulting from histopathological assessment, was 64%. False-negative results caused by a radiological error comprised 1.5% of all histopathologically diagnosed cancers and atypias (sensitivity of 98.5%). There were no false-positive results in our material - the specificity of the method was 100%. Conclusions: Histopathological interpretation is a substantial cause of false-negative results of breast core needle biopsy. Thus, in case of a radiological-histopathological divergence, histopathological analysis of biopsy specimens should be repeated. The main radiological causes of false-negative results of breast core needle biopsy are as follows: sampling from an inappropriate site and histopathological non-homogeneity of cancer infiltration. (authors)

  5. False-negative results of breast core needle biopsies – retrospective analysis of 988 biopsies

    International Nuclear Information System (INIS)

    Boba, Marek; Kołtun, Urszula; Bobek-Billewicz, Barbara; Chmielik, Ewa; Eksner, Bartosz; Olejnik, Tomasz

    2011-01-01

    Breast cancer is the most common malignant neoplasm and the most common cause of death among women. The core needle biopsy is becoming a universal practice in diagnosing breast lesions suspected of malignancy. Unfortunately, breast core needle biopsies also bear the risk of having false-negative results. 988 core needle breast biopsies were performed at the Maria Skłodowska-Curie Memorial Cancer Center and Institute of Oncology, Gliwice Branch, between 01 March 2006 and 29 February 2008. Malignant lesions were diagnosed in 426/988 (43.12%) cases, atypical hyperplasia in 69/988 (6.98%), and benign lesions in 493/988 (49.90%) cases. Twenty-two out of 988 biopsies (2.23%) were found to be false negative. Histopathological assessment of tissue specimens was repeated in these cases. In 14/22 (64%) cases, the previous diagnosis of a benign lesion was changed. In 8/22 (36%) cases, the diagnosis of a benign lesion was confirmed. False-negative rate was calculated at 2.2%. The rate of false-negative diagnoses resulting from a radiological mistake was estimated at 36%. The rate of false-negative diagnoses, resulting from histopathological assessment, was 64%. False-negative results caused by a radiological error comprised 1.5% of all histopathologically diagnosed cancers and atypias (sensitivity of 98.5%). There were no false-positive results in our material - the specificity of the method was 100%. Histopathological interpretation is a substantial cause of false-negative results of breast core needle biopsy. Thus, in case of a radiological-histopathological divergence, histopathological analysis of biopsy specimens should be repeated. The main radiological causes of false-negative results of breast core needle biopsy are as follows: sampling from an inappropriate site and histopathological non-homogeneity of cancer infiltration

  6. The Study for Results of Complex Cystic Breast Masses by Biopsy on Ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Hye Kyoung [Dept. of Radiology, Yangji General Hospital, Kwangju (Korea, Republic of); Dong, Kyung Rae [Dept. of Radiological Technology, Gwangju Health College, Kwangju (Korea, Republic of)

    2008-06-15

    We examined the roles of Ultrasonography conductors by analyzing the results of tissue biopsy of complex cystic masse under the guidance of breast US. This study was performed to a group of 178 who showed breast US indicating complex cystic masses among 342 patients who were definitely diagnosed by tissue biopsies and operations in our hospital from June 30th, 2003 to June 30th, 2007. The evaluation of tissues around, calcification, the distribution state of blood flow were excluded from the analysis subjects and logic 200 made by GE corporation and gun for core biopsy(Kimal corp., K7/MBD23) were used in this study. The biopsy results of 178 subjects showed FCC (fibrocystic change)(n=56 : 31.4%), Fibrosis (n=41 : 23.0%), Fibroadenoma (n=20 : 11.2%), Epithelial hyperplasia (n=17 : 9.6%), Carcinoma (n=15 : 8.4%), Fibroadipose (n=8 : 4.5%), Sclerosing adenosis (n=7 : 3.9%), Duct ectasia (n=5 : 2.8%), Papiloma (n=5 : 2.8%), and Fat necrosis (n=1 : 0.6%), Hemangioma (n=1 : 0.6%), Abscess (n=1 : 0.6%), Dystrophic calcification(n=1 : 0.6%). The US showed that the results of the tissue biopsy of complex cystic masses were mostly carcinoma(8.4%). Most of them were benign and only 9.6% of epithelial hyperplasia which has high progression rate into malignant tumors epidemically showed malignancy. Most of them were included in the spectrum of fibrous cystic nodule. Even though these results are confirmed, further studies are required. As a result, a nodule which is not certified by US should be right to take the tissue biopsy, but if it's difficult due to patients or another reasons, re-check tests in three months are required. And systemic ultrasonography evaluation should be well recognized to conduct more careful and specific tests.

  7. The Study for Results of Complex Cystic Breast Masses by Biopsy on Ultrasound

    International Nuclear Information System (INIS)

    Kang, Hye Kyoung; Dong, Kyung Rae

    2008-01-01

    We examined the roles of Ultrasonography conductors by analyzing the results of tissue biopsy of complex cystic masse under the guidance of breast US. This study was performed to a group of 178 who showed breast US indicating complex cystic masses among 342 patients who were definitely diagnosed by tissue biopsies and operations in our hospital from June 30th, 2003 to June 30th, 2007. The evaluation of tissues around, calcification, the distribution state of blood flow were excluded from the analysis subjects and logic 200 made by GE corporation and gun for core biopsy(Kimal corp., K7/MBD23) were used in this study. The biopsy results of 178 subjects showed FCC (fibrocystic change)(n=56 : 31.4%), Fibrosis (n=41 : 23.0%), Fibroadenoma (n=20 : 11.2%), Epithelial hyperplasia (n=17 : 9.6%), Carcinoma (n=15 : 8.4%), Fibroadipose (n=8 : 4.5%), Sclerosing adenosis (n=7 : 3.9%), Duct ectasia (n=5 : 2.8%), Papiloma (n=5 : 2.8%), and Fat necrosis (n=1 : 0.6%), Hemangioma (n=1 : 0.6%), Abscess (n=1 : 0.6%), Dystrophic calcification(n=1 : 0.6%). The US showed that the results of the tissue biopsy of complex cystic masses were mostly carcinoma(8.4%). Most of them were benign and only 9.6% of epithelial hyperplasia which has high progression rate into malignant tumors epidemically showed malignancy. Most of them were included in the spectrum of fibrous cystic nodule. Even though these results are confirmed, further studies are required. As a result, a nodule which is not certified by US should be right to take the tissue biopsy, but if it's difficult due to patients or another reasons, re-check tests in three months are required. And systemic ultrasonography evaluation should be well recognized to conduct more careful and specific tests.

  8. Postradiotherapy prostate biopsies: what do they really mean? results for 498 patients

    International Nuclear Information System (INIS)

    Crook, Juanita; Malone, Shawn; Perry, Gad; Bahadur, Yasir; Robertson, Susan; Abdolell, Mohamed

    2000-01-01

    Purpose: Postradiotherapy (RT) prostate biopsies are prone to problems in interpretation. False negatives due to sampling error, false positives due to delayed tumor regression, and indeterminate biopsies showing radiation effect in residual tumor of uncertain viability are common occurrences. Methods and Materials: A cohort of 498 men treated with conventional RT from 06/87-10/96 were followed prospectively with systematic transrectal ultrasound (TRUS)-guided post-RT prostate biopsies, starting 12-18 months after RT. If there was residual tumor but further decline in serum prostate-specific antigen (PSA), biopsies were repeated every 6-12 months. Patients with negative biopsies were rebiopsied at 36 months. Residual tumor was evaluated for RT effect and proliferation markers. The 498 men had 978 biopsies. Median time of the first biopsy (n = 498) was 13 months, biopsy no. 2 (n = 342) 28 months, biopsy no. 3 (n = 110) 36 months, biopsy no. 4 (n = 28) 44 months, and biopsy no. 5 (n = 4) 55 months. Median follow-up is 54 months (range 13-131). One hundred seventy-five patients (34%) had prior hormonal therapy for a median of 5 months (range 1-60). Results: Clinical stage distribution was T1b: 46; T1c: 50; T2a: 115; T2b/c: 170; T3: 108; T4: 11; Tx: 1. Distribution by Gleason score was: 28% Gleason score 2-4; 42%: 5-6; 18%: 7; and 12%: 8-10. Seventy-one men have died, 26 of prostate cancer and 45 of other causes. Actuarial failure-free survival by T stage at 5 years is T1b: 78%; T1c: 76%; T2a: 60%; T2b/c: 55%; T3: 30%; and T4: 0%. Actuarial freedom from local failure at 5 years is T1b: 83%; T1c: 88%; T2a: 72%; T2b/c: 66%; T3: 58%; and T4: 0%. The proportion of indeterminate biopsies decreases with time, being 33% for biopsy 1, 24% for biopsy 2, 18% for biopsy 3, and 7% for biopsy 4. Thirty percent of indeterminate biopsies resolved to NED status, regardless of the degree of RT effect, 18% progressed to local failure, and 34% remained as biopsy failures with

  9. Results and complications of CT-guided biopsy with CT fluoroscopy

    International Nuclear Information System (INIS)

    Saika, Yoshinori; Ogura, Yasuharu; Doi, Kenji; Misaki, Toshimasa; Shimizu, Masashi; Narabayashi, Isamu

    2002-01-01

    We studied the results and complications of CT-guided biopsy with CT fluoroscopy performed 66 lesions in 64 patients from March 1999 to February 2001. In addition to the conventional procedure of CT-guided biopsy, we use CT fluoroscopy for confirmation of the location of the tip of the biopsy needle and the accurate contact, in some cases, at the time of puncturing. Examination results showed malignancy in 36 lesions and benign findings in 30 lesions. The sensitivity was 85.7%, specificity was 100.0%, and accuracy was 90.9%. Pneumothorax occurred in 20 out of 64 patients (31.3%). In a study on 26 small lesions (≤2 cm) in 25 patients, the sensitivity was 81.8%, specificity was 100.0%, accuracy was 92.3%. Pneumothorax occurred in 12 out of 25 patients (48.0%), more frequently than in patients with large lesions. In a study on 6 false negative cases, they tended to be intrapulmonary on location, small in diameter, and far from the skin puncture point. Examination results were satisfactory, especially in terms of accuracy in small lesions (≤2 cm). However, when the lesions were small, pneumothorax occurred frequently (48.0%). (author)

  10. How to Interpret Thyroid Biopsy Results: A Three-Year Retrospective Interventional Radiology Experience

    International Nuclear Information System (INIS)

    Oppenheimer, Jason D.; Kasuganti, Deepa; Nayar, Ritu; Chrisman, Howard B.; Lewandowski, Robert J.; Nemcek, Albert A.; Ryu, Robert K.

    2010-01-01

    Results of thyroid biopsy determine whether thyroid nodule resection is appropriate and the extent of thyroid surgery. At our institution we use 20/22-gauge core biopsy (CBx) in conjunction with fine-needle aspiration (FNA) to decrease the number of passes and improve adequacy. Occasionally, both ultrasound (US)-guided FNA and CBx yield unsatisfactory specimens. To justify clinical recommendations for these unsatisfactory thyroid biopsies, we compare rates of malignancy at surgical resection for unsatisfactory biopsy results against definitive biopsy results. We retrospectively reviewed a database of 1979 patients who had a total of 2677 FNA and 663 CBx performed by experienced interventional radiologists under US guidance from 2003 to 2006 at a tertiary-care academic center. In 451 patients who had surgery following biopsy, Fisher's exact test was used to compare surgical malignancy rates between unsatisfactory and malignant biopsy cohorts as well as between unsatisfactory and benign biopsy cohorts. We defined statistical significance at P = 0.05. We reported an overall unsatisfactory thyroid biopsy rate of 3.7% (100/2677). A statistically significant higher rate of surgically proven malignancies was found in malignant biopsy patients compared to unsatisfactory biopsy patients (P = 0.0001). The incidence of surgically proven malignancy in unsatisfactory biopsy patients was not significantly different from that in benign biopsy patients (P = 0.8625). In conclusion, an extremely low incidence of malignancy was associated with both benign and unsatisfactory thyroid biopsy results. The difference in incidence between these two groups was not statistically significant. Therefore, patients with unsatisfactory biopsy specimens can be reassured and counseled accordingly.

  11. Biopsy results of Bosniak 2F and 3 cystic lesions

    DEFF Research Database (Denmark)

    Rasmussen, René; Hørlyck, Arne; Nielsen, Tommy Kjærgaard

    be helpful in clinical decisions. Material and Methods: From March 2013 - December 2014 a total of 295 percutaneous ultrasound guided biopsies from 287 patients with a suspected malignant renal lesion were performed at our institution. All cases were reviewed in PACS by (RR) and lesions presenting...... with a cystic change were re-evaluated and re-categorized after the Bosniak classification system. The re-evaluation and re-categorization was performed in consensus by a junior radiologist (RR) and an uro-radiological expert (OG). Results: Biopsies from eighteen Bosniak 2F cystic lesions were pathologically...... analyzed and three (17%) proved to be malignant. Biopsies from seventeen Bosniak 3 cystic lesions were pathologically analyzed and five (29%) were found to be malignant. Conclusion: Our results reveal a considerable malignancy rate among both Bosniak 2F and 3 cystic renal lesions. Biopsy seems...

  12. Posttreatment biopsy results following interstitial brachytherapy in early-stage prostate cancer

    International Nuclear Information System (INIS)

    Prestidge, Bradley R.; Hoak, David C.; Grimm, Peter D.; Ragde, Haakon; Cavanagh, William; Blasko, John C.

    1997-01-01

    Purpose: To assess pathologic control rates for prostatic carcinoma as determined by postimplant prostate biopsy in a large series of consecutive patients who have received permanent interstitial brachytherapy using a contemporary transrectal ultrasound-directed, transperineal, computer generated, volume technique. Methods and Materials: Four hundred and two patients received permanent 125 I or 103 Pd interstitial brachytherapy as primary treatment for early stage prostatic carcinoma at the Northwest Tumor Institute between January 1988 and January 1994. Of these, 201 have consented to biopsy 12 or more months postimplant with a median follow-up of 40 months (range: 12-83 months). None had received homonal manipulation. A total of 361 biopsies was performed on 201 patients with a range of one to six annual biopsies per patient (91 received multiple, serial biopsies). Of the 161 patients more than 12 months postimplant who have not been biopsied, most have been unwilling or unable to submit to biopsy. Only six patients with biochemical progression have not been biopsied. There was no difference in the presenting characteristics or implant parameters between those patients biopsied and those that were not. One hundred and forty-three received 125 I (71%) prescribed to a MPD of 160 Gy with a median activity of 35.5 mCi, and 58 (29%) received 103 Pd prescribed to a MPD of 115 Gy with a median activity of 123 mCi. Multiple biopsies were performed under transrectal ultrasound guidance, and all specimens were classified as either negative, indeterminate, or positive. Results: At the time of last biopsy, 161 (80%) have achieved negative pathology, 34 (17%) remain indeterminate, and 6 (3%) have been positive. Only 2 of the 186 patients with a PSA < 4.0 ng/ml at the time of biopsy were positive. Among those 33 indeterminate patients with a subsequent biopsy, 28 have converted to negative, 2 to positive, and 3 remain unchanged to date. Conclusions: These data demonstrate at

  13. Percutaneous CT-guided biopsy of the musculoskeletal system: Results of 2027 cases

    International Nuclear Information System (INIS)

    Rimondi, Eugenio; Rossi, Giuseppe; Bartalena, Tommaso; Ciminari, Rosanna; Alberghini, Marco; Ruggieri, Pietro; Errani, Costantino; Angelini, Andrea; Calabro, Teresa; Abati, Caterina Novella; Balladelli, Alba; Tranfaglia, Cristina; Mavrogenis, Andreas F.; Vanel, Daniel; Mercuri, Mario

    2011-01-01

    Introduction: Biopsy of the musculoskeletal system is useful in the management of bone lesions particularly in oncology but they are often challenging procedures with a significant risk of complications. Computed tomography (CT)-guided needle biopsies may decrease these risks but doubts still exist about their diagnostic accuracy. This retrospective analysis of the experience of a single institution with percutaneous CT-guided biopsy of musculoskeletal lesions evaluates the results of these biopsies for bone lesions either in the appendicular skeleton or in the spine, and defines indications. Materials and methods: We reviewed the results of 2027 core needle biopsies performed over the past 18 years at the authors' institution. The results obtained are subject of this paper. Results: In 1567 cases the correct diagnosis was made with the first CT-guided needle biopsy (77.3% accuracy rate), in 408 cases the sample was not diagnostic and in 52 inadequate. Within 30 days these 408 patients underwent another biopsy, which was diagnostic in 340 cases with a final diagnostic accuracy of 94%. Highest accuracy rates were obtained in primary and secondary malignant lesions. Most false negative results were found in cervical lesions and in benign, pseudotumoral, flogistic, and systemic pathologies. There were 22 complications (18 transient paresis, 3 haematomas, 1 retroperitoneal haematoma) which had no influence on the treatment strategy, nor on patient outcome. Conclusion: This technique is reliable and safe and should be considered nowadays the gold standard for biopsies of the musculoskeletal system.

  14. Electromagnetic-Tracked Biopsy under Ultrasound Guidance: Preliminary Results

    International Nuclear Information System (INIS)

    Hakime, Antoine; Deschamps, Frederic; Marques De Carvalho, Enio Garcia; Barah, Ali; Auperin, Anne; Baere, Thierry De

    2012-01-01

    Purpose: This study was designed to evaluate the accuracy and safety of electromagnetic needle tracking for sonographically guided percutaneous liver biopsies. Methods: We performed 23 consecutive ultrasound-guided liver biopsies for liver nodules with an electromagnetic tracking of the needle. A sensor placed at the tip of a sterile stylet (18G) inserted in a coaxial guiding trocar (16G) used for biopsy was localized in real time relative to the ultrasound imaging plane, thanks to an electromagnetic transmitter and two sensors on the ultrasound probe. This allows for electronic display of the needle tip location and the future needle path overlaid on the real-time ultrasound image. Distance between needle tip position and its electronic display, number of needle punctures, number of needle pull backs for redirection, technical success (needle positioned in the target), diagnostic success (correct histopathology result), procedure time, and complication were evaluated according to lesion sizes, depth and location, operator experience, and “in-plane” or “out-of-plane” needle approach. Results: Electronic display was always within 2 mm from the real position of the needle tip. The technical success rate was 100%. A single needle puncture without repuncture was used in all patients. Pull backs were necessary in six patients (26%) to obtain correct needle placement. The overall diagnostic success rate was 91%. The overall true-positive, true-negative, false-negative, and failure rates of the biopsy were 100% (19/19) 100% (2/2), 0% (0/23), and 9% (2/23). The median total procedure time from the skin puncture to the needle in the target was 30 sec (from 5–60 s). Lesion depth and localizations, operator experience, in-plane or out-of-plane approach did not affect significantly the technical, diagnostic success, or procedure time. Even when the tumor size decreased, the procedure time did not increase. Conclusions: Electromagnetic-tracked biopsy is accurate to

  15. MR-guided biopsies of lesions in the retroperitoneal space: technique and results

    International Nuclear Information System (INIS)

    Zangos, S.; Eichler, K.; Wetter, A.; Lehnert, T.; Hammerstingl, R.; Diebold, T.; Reichel, P.; Herzog, C.; Mack, M.G.; Vogl, T.J.; Hansmann, M.-L.

    2006-01-01

    The purpose of this study was to evaluate the safety and precision of MRI-guided biopsies of retroperitoneal space-occupying tumors in an open low-field system. In 30 patients with indistinct retroperitoneal tumors [paraaortic lesion (n=20), kidney (n=2), suprarenal gland (n=3) and pancreas (n=5)] MR-guided biopsies were performed using a low-field system (0.2 T, Magnetom Concerto, Siemens, Germany). For the monitoring of the biopsies T1-weighted FLASH sequences (TR/TE=160/5 ms; 90 ) were used in all patients and modified FLASH sequences (TR/TE=160/13 ms; 90 ) in ten patients. After positioning of the needle in the tumors 114 biopsy specimens were acquired in coaxial technique with 16-gauge cutting needles (Somatex, Germany). The biopsies were successfully performed in all patients without vascular or organ injuries. The visualization of the aortic blood flow with MRI facilitated the biopsy procedures of paraaortic lesions. The size of the lesions ranged from 1.6 to 7.5 cm. The median distance of the biopsy access path was 10.4 cm. Adequate specimens were obtained in 28 cases (93.3%) resulting in a correct histological classification of 27 lesions (90%). In conclusion, MR-guided biopsies of retroperitoneal lesions using an open low-field system can be performed safely and accurately and is an alternative to CT-guided biopsies. (orig.)

  16. When size matters: diagnostic value of kidney biopsy according to the gauge of the biopsy needle.

    Science.gov (United States)

    Roth, Rachel; Parikh, Samir; Makey, Dayanand; Foster, Jamison; Rozenblit, Grigory; Satoskar, Anjali; Nadasdy, Gyongyi; Von Visger, Jon; Hebert, Lee; Rovin, Brad H; Nadasdy, Tibor; Brodsky, Sergey V

    2013-01-01

    Kidney biopsy is a vital tool in the diagnosis of kidney disease. Although it has become a routine procedure, it is not complication-free. Some serious complications of percutaneous kidney biopsy include retroperitoneal hemorrhage and death. There is an increased belief that smaller biopsy needle size results in a lower complication rate. As renal pathologists, we witness an increased number of kidney biopsies performed with a small needle size (as low as gauge 22), which results in inadequate tissue sampling and often non-diagnostic biopsy results. Herein we report the diagnostic value of kidney biopsies according to the size of the biopsy needles. We performed kidney biopsies from nephrectomy specimens using biopsy needles of different sizes. Morphologic parameters were analyzed. We found that biopsies performed by small needles (gauges 20 and 22) contain significantly lower numbers of glomeruli and blood vessels, which limits pathologic evaluation. Data from our institution do not show differences in kidney biopsy complication rates between 16- and 18-gauge needles. Our data indicate that small biopsy needles do not provide sufficient material for diagnosis, and they increase the likelihood for a repeat biopsy. Copyright © 2013 S. Karger AG, Basel.

  17. Biopsy system for CT-guided biopsies

    International Nuclear Information System (INIS)

    Onik, G.; Cosman, E.; Wells, T.; Goldberg, H.I.; Moss, A.; Costello, P.; Kane, R.

    1987-01-01

    CT stereotaxic brain biopsies have made brain biopsies safe and minimally invasive. CT-guided biopsies of the body, however, have traditionally used a hand-guidance method. CT biopsy guidance systems for the body have recently become available that have similar capabilities as those of brain biopsy systems. To compare the clinical utility of stereotaxically guided biopsies with hand-guided biopsies, the authors prospectively compared 40 biopsies performed with each method. In the stereotaxic method, a localizor grid was placed on the patient to define a reference point, and a frame was used to guide the needle along the intended path. Computer software programs calculated complex paths from one scan plane to another. Although the results disclosed no significant differences in lesion size or path length between the two groups, the stereotaxically guided biopsies required 75% fewer needle manipulations to hit the intended target. Consequently, the stereotaxically guided biopsies required 40% less time and 80% fewer localization scans to find the biopsy needle than did the hand-guided biopsies

  18. Stereotactic breast biopsy with a biopsy gun

    International Nuclear Information System (INIS)

    Parker, S.H.; Lovin, J.; Luethke, J.; Jobe, W.E.; Hopper, K.D.; Yakes, W.F.

    1989-01-01

    With the recent introduction of stereotactic mammographic localizing devices, the authors have been performing histologic core needle breast biopsies in which the Bard biopsy gun is used in conjunction with sterotactic guidance. The authors have performed 60 breast gun biopsies with 16-gauge and 18-gauge biopsy-cut needles. These biopsies were followed immediately by traditional surgical excision. Pathologic results correlated well in 52 of the 60 patients, including 10 of 13 cancers. Three of the eight negative correlations occurred when diagnosis was made on gun biopsy but not on surgical biopsy. The stereotactic- guided gun biopsies appear to approach the surgical gold standard, decrease patient discomfort and potential disfigurement, lower the cost of breast biopsy, and lower the threshold necessary to perform breast biopsy

  19. Modified Core Wash Cytology: A reliable same day biopsy result for breast clinics.

    Science.gov (United States)

    Bulte, J P; Wauters, C A P; Duijm, L E M; de Wilt, J H W; Strobbe, L J A

    2016-12-01

    Fine Needle Aspiration Biopsy (FNAB), Core Needle biopsy (CNB) and hybrid techniques including Core Wash Cytology (CWC) are available for same-day diagnosis in breast lesions. In CWC a washing of the biopsy core is processed for a provisional cytological diagnosis, after which the core is processed like a regular CNB. This study focuses on the reliability of CWC in daily practice. All consecutive CWC procedures performed in a referral breast centre between May 2009 and May 2012 were reviewed, correlating CWC results with the CNB result, definitive diagnosis after surgical resection and/or follow-up. Symptomatic as well as screen-detected lesions, undergoing CNB were included. 1253 CWC procedures were performed. Definitive histology showed 849 (68%) malignant and 404 (32%) benign lesions. 80% of CWC procedures yielded a conclusive diagnosis: this percentage was higher amongst malignant lesions and lower for benign lesions: 89% and 62% respectively. Sensitivity and specificity of a conclusive CWC result were respectively 98.3% and 90.4%. The eventual incidence of malignancy in the cytological 'atypical' group (5%) was similar to the cytological 'benign' group (6%). CWC can be used to make a reliable provisional diagnosis of breast lesions within the hour. The high probability of conclusive results in malignant lesions makes CWC well suited for high risk populations. Copyright © 2016 Elsevier Ltd, BASO ~ the Association for Cancer Surgery, and the European Society of Surgical Oncology. All rights reserved.

  20. Magnetic Resonance and Ultrasound Image Fusion Supported Transperineal Prostate Biopsy Using the Ginsburg Protocol: Technique, Learning Points, and Biopsy Results.

    Science.gov (United States)

    Hansen, Nienke; Patruno, Giulio; Wadhwa, Karan; Gaziev, Gabriele; Miano, Roberto; Barrett, Tristan; Gnanapragasam, Vincent; Doble, Andrew; Warren, Anne; Bratt, Ola; Kastner, Christof

    2016-08-01

    Prostate biopsy supported by transperineal image fusion has recently been developed as a new method to the improve accuracy of prostate cancer detection. To describe the Ginsburg protocol for transperineal prostate biopsy supported by multiparametric magnetic resonance imaging (mpMRI) and transrectal ultrasound (TRUS) image fusion, provide learning points for its application, and report biopsy results. The article is supplemented by a Surgery in Motion video. This single-centre retrospective outcome study included 534 patients from March 2012 to October 2015. A total of 107 had no previous prostate biopsy, 295 had benign TRUS-guided biopsies, and 159 were on active surveillance for low-risk cancer. A Likert scale reported mpMRI for suspicion of cancer from 1 (no suspicion) to 5 (cancer highly likely). Transperineal biopsies were obtained under general anaesthesia using BiopSee fusion software (Medcom, Darmstadt, Germany). All patients had systematic biopsies, two cores from each of 12 anatomic sectors. Likert 3-5 lesions were targeted with a further two cores per lesion. Any cancer and Gleason score 7-10 cancer on biopsy were noted. Descriptive statistics and positive predictive values (PPVs) and negative predictive values (NPVs) were calculated. The detection rate of Gleason score 7-10 cancer was similar across clinical groups. Likert scale 3-5 MRI lesions were reported in 378 (71%) of the patients. Cancer was detected in 249 (66%) and Gleason score 7-10 cancer was noted in 157 (42%) of these patients. PPV for detecting 7-10 cancer was 0.15 for Likert score 3, 0.43 for score 4, and 0.63 for score 5. NPV of Likert 1-2 findings was 0.87 for Gleason score 7-10 and 0.97 for Gleason score ≥4+3=7 cancer. Limitations include lack of data on complications. Transperineal prostate biopsy supported by MRI/TRUS image fusion using the Ginsburg protocol yielded high detection rates of Gleason score 7-10 cancer. Because the NPV for excluding Gleason score 7-10 cancer was very

  1. Association of serum prostate-specific antigen levels with the results of the prostate needle biopsy.

    Science.gov (United States)

    Janbaziroudsari, Hamid; Mirzaei, Arezoo; Maleki, Nasrollah

    2016-09-01

    To investigate the relationship of serum prostate-specific antigen (PSA) levels with outcomes of prostate needle biopsy in men 50 or more years old. We measured serum PSA levels in 1472 healthy men 50 or more years old. Men who had serum PSA values 4.0ng/mL or higher underwent digital rectal examination. If there were either an elevated PSA level (≥4ng/mL) or abnormal digital rectal examination, a transrectal ultrasound-guided prostate biopsy was performed. The mean serum total PSA level was 13.73±11.44ng/mL, and the mean serum free PSA level was 4.99±0.97ng/mL. Of the 260 men who had serum total PSA levels of≥4ng/mL, 139 underwent biopsy. Of these 139 men, 45 (32.4%) had prostate cancer. Benign prostatic hyperplasia with or without prostatitis was diagnosed in 94 patients (67.6%). There was no significant correlation between age and histologic results of prostate needle biopsy (P-value=0.469). The serum free PSA showed no significant correlation with histologic results of prostate needle biopsy, whereas the serum total PSA level had a significant correlation in patients with adenocarcinoma compared with other diagnosis. The overall frequency of detection of prostate adenocarcinoma was 32.4%. This study revealed that no level of PSA was associated with a 100% positive predictive value and negative biopsy can occur virtually at any PSA level. There is a need to create awareness among the general population and health professionals for an early diagnosis of this common form of cancer. Copyright © 2016 Société Française du Cancer. Published by Elsevier Masson SAS. All rights reserved.

  2. Functional quality of MR-compatible automatic biopsy guns compared with conventional ferromagnetic biopsy systems. An in vitro study

    International Nuclear Information System (INIS)

    Langen, H.J.; Landwehr, P.

    2001-01-01

    Comparative evaluation of specimens obtained with different MR-compatible biopsy systems and a conventional ferromagnetic system. Methods: Biopsies of a pig liver were performed post-mortem with three different MR-compatible (Somatex; E-Z-EM; Daum) and one conventional biopsy system (Somatex), five with each device. The specimens were measured and the histopathological quality was graded on a scale from 0 (no tissue) to 9 (best). The tip of the needle was examined with an electron microscope before and after biopsy to demonstrate abrasion. Results: The histopathological score between the first and fifth specimen taken with one biopsy device showed no significant difference. The conventional system yielded significantly better results in nearly all categories (p 2 ) were significantly smaller than those from the conventional system (9.98 mm 2 ). The needle tip abrasion of the different biopsy systems determined by electron microscopy showed no substantial difference. (orig.) [de

  3. Ultrasonography-guided core needle biopsy for the thyroid nodule: does the procedure hold any benefit for the diagnosis when fine-needle aspiration cytology analysis shows inconclusive results?

    Science.gov (United States)

    Hahn, S Y; Han, B-K; Ko, E Y; Ko, E S

    2013-01-01

    Objective: We evaluated the diagnostic role of ultrasonography-guided core needle biopsy (CNB) according to ultrasonography features of thyroid nodules that had inconclusive ultrasonography-guided fine-needle aspiration (FNA) results. Methods: A total of 88 thyroid nodules in 88 patients who underwent ultrasonography-guided CNB because of previous inconclusive FNA results were evaluated. The patients were classified into three groups based on ultrasonography findings: Group A, which was suspicious for papillary thyroid carcinoma (PTC); Group B, which was suspicious for follicular (Hurthle cell) neoplasm; and Group C, which was suspicious for lymphoma. The final diagnoses of the thyroid nodules were determined by surgical confirmation or follow-up after ultrasonography-guided CNB. Results: Of the 88 nodules, the malignant rate was 49.1% in Group A, 12.0% in Group B and 90.0% in Group C. The rates of conclusive ultrasonography-guided CNB results after previous incomplete ultrasonography-guided FNA results were 96.2% in Group A, 64.0% in Group B and 90.0% in Group C (p=0.001). 12 cases with inconclusive ultrasonography-guided CNB results were finally diagnosed as 8 benign lesions, 3 PTCs and 1 lymphoma. The number of previous ultrasonography-guided FNA biopsies was not significantly different between the conclusive and the inconclusive result groups of ultrasonography-guided CNB (p=0.205). Conclusion: Ultrasonography-guided CNB has benefit for the diagnosis of thyroid nodules with inconclusive ultrasonography-guided FNA results. However, it is still not helpful for the differential diagnosis in 36% of nodules that are suspicious for follicular neoplasm seen on ultrasonography. Advances in knowledge: This study shows the diagnostic contribution of ultrasonography-guided CNB as an alternative to repeat ultrasonography-guided FNA or surgery. PMID:23564885

  4. MR-guided biopsies of undetermined liver lesions: technique and results; MRT-gezielte perkutane Biopsie bei unklaren fokalen Leberlaesionen: Technik und Ergebnisse

    Energy Technology Data Exchange (ETDEWEB)

    Zangos, S.; Kiefl, D.; Eichler, K.; Engelmann, K.; Heller, M.; Herzog, C.; Mack, M.G.; Jacobi, V.; Vogl, T.J. [Inst. fuer Diagnostische und Interventionelle Radiologie, Johann-Wolfgang-Goethe-Univ. Frankfurt (Germany)

    2003-05-01

    Purpose: To evaluate safety and precision of liver tumor biopsies performed in an open low field system using different sequence techniques. Materials and Methods: In 47 patients with liver tumors, MR-guided biopsies were performed in a low field system (0.2 Tesla, Magnetom Open, Siemens) using two different sequences. The procedure was monitored with T1-weighted FLASH sequences (TR/TE = 100/9; 70 ) in all patients and with FISP-Rotated-Keyhole-sequence (TR/TE = 18/8; 90 ) in additional 20 patients. After positioning of the needle tip in the tumors, 166 biopsy specimens were acquired with 16 G cutting needles (Somatex{sup *}). The diameter of the biopsied lesions ranged from 1 to 10 cm (mean diameter 3.2 cm). Visibility of the needles and precision of the biopsies were evaluated. Results: All interventional biopsies were performed without vascular or organ injuries. Adequate specimens for histologic interpretation were obtained in 42 cases (89.3%). The biopsy results were non-specific in 2 patients (4.2%) and the lesions missed in 3 patients (6.3%). Mean in-room time was 35 minutes and the intervention time was 8.3 minutes. T1-weighted FLASH images proved optimal for confirming needle-tip placement during the biopsies or punctures. Organs, tumors and vessels were easily identified. The FISP sequence proved to be inferior in visualizing vessels and tumors. Conclusion: MR-guided liver biopsies are safely and precisely performed using T1-weighted FLASH-sequences with sufficient visualization of the lesions and might be complementary to US- or CT-guided biopsies. (orig.) [German] Zielsetzung: Evaluierung der Sicherheit und Genauigkeit MRT-gezielter Leberbiopsien unter Verwendung verschiedener Sequenzen. Methoden: Bei 47 Patienten mit unklaren Leberlaesionen wurden in einem offenen 0,2-Tesla-MR-System (Magnetom Open, Siemens) bildgesteuerte Biopsien unter Verwendung von zwei verschiedenen Sequenzen durchgefuehrt. Die Bildgebung erfolgte bei allen Patienten mittels T

  5. Hematoxylin and eosin stain shows a high sensitivity but sub-optimal specificity in demonstrating iron pigment in liver biopsies.

    Science.gov (United States)

    Alwahaibi, Nasar Yousuf; Alkhatri, Azza Sarhan; Kumar, Johanes Selva

    2015-01-01

    Perls' stain is routinely used to demonstrate iron in liver biopsies. We tested the hypothesis that it may be unnecessary in cases, where no iron or another similar pigment was seen on the routine hematoxylin and eosin (H and E) stained section. The aim of this study was to evaluate the efficiency of H and E stain in demonstrating iron in liver biopsies as well as to determine the possibility of replacing Perls' stain with H and E stain. Two hundred pairs of slides of liver biopsies were taken from the archival files of the Department of Pathology from 2006 to 2011. Perls' and H and E slides were independently reviewed for the presence of iron. Hundred and one cases showed the presence of iron using H and E stain. 84 of 86 cases showed positive iron using both Perls' and H and E stains. Seventeen cases were positive using H and E stain but negative with Perls'. Only two cases did not show the presence of iron using H and E stain. Ninety-seven cases were negative using both Perls' and H and E stains. H and E stain showed a sensitivity, specificity, accuracy, positive predictive valve, and negative predictive value of 97.67%, 85.08%, 90.5%, 83.16%, and 97.98%, respectively. We demonstrate that the H and E stain is a sensitive method to detect iron pigment in liver biopsies, particularly when present in large quantities. A negative H and E stain might obviate the need for extra Perls' staining, thus saving costs and shortening report turn-around times.

  6. Image-Guided percutaneous biopsies with a biopsy gun

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kyung Hwan; Lim, Hyo Keun; Kim, Eun Ah; Yun, Ku Sub; Bae, Sang Hoo; Shin, Hyung Sik [Hallym University College of Medicine, Seoul (Korea, Republic of)

    1994-07-15

    We report the results of image-guided percutaneous biopsies with a biopsy gun and evaluate the clinical usefulness. One hundred and five biopsies under ultrasonographic or fluoroscopic guidance were performed. Various anatomic sites were targeted(liver; 50, chest; 22, kidney; 12, pancreas; 8, intraperitoeum; 7, retroperitoneum; ). Obtained tissue was diagnostic in 98 of the 105 biopsies(93%). In each instance, representative core tissue specimens were obtained. Evaluation of the core tissue by pathologist revealed consistent, uniform specimens that contained significant crush artifact in no case. Five biopsies yielded inadequate tissue which were too small for histopathologic interpretation or were composed of necrotic debris. Two biopsies yielded adequate tissues, but tissues were not of the target. The diagnoses were malignancy in 77 biopsies and benign disease in 21 biopsies. No complications other than mild, localized discomfort were encountered except a transient hemoptysis and pneumothorax which was observed in two patients. Cutting biopsy with a biopsy gun provided sufficient amount of target tissue for an accurate diagnosis of malignant and benign disease. It was a safe and useful procedure for percutaneous biopsy.

  7. Clinical validation of an epigenetic assay to predict negative histopathological results in repeat prostate biopsies.

    Science.gov (United States)

    Partin, Alan W; Van Neste, Leander; Klein, Eric A; Marks, Leonard S; Gee, Jason R; Troyer, Dean A; Rieger-Christ, Kimberly; Jones, J Stephen; Magi-Galluzzi, Cristina; Mangold, Leslie A; Trock, Bruce J; Lance, Raymond S; Bigley, Joseph W; Van Criekinge, Wim; Epstein, Jonathan I

    2014-10-01

    The DOCUMENT multicenter trial in the United States validated the performance of an epigenetic test as an independent predictor of prostate cancer risk to guide decision making for repeat biopsy. Confirming an increased negative predictive value could help avoid unnecessary repeat biopsies. We evaluated the archived, cancer negative prostate biopsy core tissue samples of 350 subjects from a total of 5 urological centers in the United States. All subjects underwent repeat biopsy within 24 months with a negative (controls) or positive (cases) histopathological result. Centralized blinded pathology evaluation of the 2 biopsy series was performed in all available subjects from each site. Biopsies were epigenetically profiled for GSTP1, APC and RASSF1 relative to the ACTB reference gene using quantitative methylation specific polymerase chain reaction. Predetermined analytical marker cutoffs were used to determine assay performance. Multivariate logistic regression was used to evaluate all risk factors. The epigenetic assay resulted in a negative predictive value of 88% (95% CI 85-91). In multivariate models correcting for age, prostate specific antigen, digital rectal examination, first biopsy histopathological characteristics and race the test proved to be the most significant independent predictor of patient outcome (OR 2.69, 95% CI 1.60-4.51). The DOCUMENT study validated that the epigenetic assay was a significant, independent predictor of prostate cancer detection in a repeat biopsy collected an average of 13 months after an initial negative result. Due to its 88% negative predictive value adding this epigenetic assay to other known risk factors may help decrease unnecessary repeat prostate biopsies. Copyright © 2014 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  8. Histopathologic quality of prostate core biopsy specimens: comparison of an MR-compatible biopsy needle and a ferromagnetic biopsy needle used for ultrasound-guided prostate biopsy

    International Nuclear Information System (INIS)

    Franiel, T.; Hamm, B.; Beyersdorff, D.; Fritzsche, F.; Staack, A.; Rost, J.

    2006-01-01

    Purpose: The histopathologic quality of core biopsy specimens obtained via MRI-guided prostate biopsy using a 16G MR-compatible needle was compared to that of biopsies obtained via ultrasound-guided biopsy using a conventional 18G stainless steel biopsy needle. Material and Methods: A retrospective analysis was performed for a total of 247 transrectal prostate biopsy specimens obtained from 32 patients. A total of 117 tissue cores were obtained from 15 patients (PSA of 10.8 ng/ml, age 64 years) who underwent an MRI-guided prostate biopsy using a 16G (1.7 mm) MR-compatible biopsy needle made of titanium alloy. The remaining 130 tissue cores were obtained from 17 patients (PSA of 6.7 ng/ml, age 68 years) who underwent a transrectal ultrasound-guided prostate biopsy using an 18G (1.3 mm) ferromagnetic stainless steel biopsy needle. The length and width of the histologic sections prepared from the tissue cores were measured to calculate the area. The histopathologic quality of the specimens was assessed microscopically using tissue fragmentation, the presence of crush artifacts, and the overall assessability as criteria. Each of these features was assigned a score from 0 to 3. All 3 features contributed equally to the overall score which ranged from 0 (no tissue) to 9 (optimal quality). Results: The overall quality scores assigned to the biopsies obtained with a 16G MR-compatible needle and an 18G ferromagnetic needle can be considered to be equivalent to a mean difference between patient related median scores of the specimens of -0.05 (95% confidence interval [-0.46; 0.36]) and a given equivalence limit of 1. The MRI biopsies showed more tissue fragmentation (p=0.001) but fewer crush artifacts (p=0.022) while the assessability did not differ significantly between the two needle types (p=0.064). There was also no significant difference in the calculated areas of the tissue cores (p=0.236). According to the different calibers of the biopsy needles, the lengths (p=0

  9. Prostate cancer detection using multiparametric 3 – tesla MRI and fusion biopsy: preliminary results

    Directory of Open Access Journals (Sweden)

    Thais Caldara Mussi

    Full Text Available ABSTRACT Objective: To evaluate the diagnostic efficacy of transrectal ultrasonography (US biopsy with imaging fusion using multiparametric (mp magnetic resonance imaging (MRI in patients with suspicion of prostate cancer (PCa, with an emphasis on clinically significant tumors according to histological criteria. Materials and Methods: A total of 189 consecutive US/MRI fusion biopsies were performed obtaining systematic and guided samples of suspicious areas on mpMRI using a 3 Tesla magnet without endorectal coil. Clinical significance for prostate cancer was established based on Epstein criteria. Results: In our casuistic, the average Gleason score was 7 and the average PSA was 5.0ng/mL. Of the 189 patients that received US/MRI biopsies, 110 (58.2% were positive for PCa. Of those cases, 88 (80% were clinically significant, accounting for 46.6% of all patients. We divided the MRI findings into 5 Likert scales of probability of having clinically significant PCa. The positivity of US/MRI biopsy for clinically significant PCa was 0%, 17.6% 23.5%, 53.4% and 84.4% for Likert scores 1, 2, 3, 4 and 5, respectively. There was a statistically significant difference in terms of biopsy results between different levels of suspicion on mpMRI and also when biopsy results were divided into groups of clinically non-significant versus clinically significant between different levels of suspicion on mpMRI (p-value <0.05 in both analyzes. Conclusion: We found that there is a significant difference in cancer detection using US/MRI fusion biopsy between low-probability and intermediate/high probability Likert scores using mpMRI.

  10. Usefulness of automated biopsy guns in image-guided biopsy

    International Nuclear Information System (INIS)

    Lee, Jung Hyung; Rhee, Chang Soo; Lee, Sung Moon; Kim, Hong; Woo, Sung Ku; Suh, Soo Jhi

    1994-01-01

    To evaluate the usefulness of automated biopsy guns in image-guided biopsy of lung, liver, pancreas and other organs. Using automated biopsy devices, 160 biopsies of variable anatomic sites were performed: Biopsies were performed under ultrasonographic(US) guidance in 95 and computed tomographic (CT) guidance in 65. We retrospectively analyzed histologic results and complications. Specimens were adequate for histopathologic diagnosis in 143 of the 160 patients(89.4%)-Diagnostic tissue was obtained in 130 (81.3%), suggestive tissue obtained in 13(8.1%), and non-diagnostic tissue was obtained in 14(8.7%). Inadequate tissue was obtained in only 3(1.9%). There was no statistically significant difference between US-guided and CT-guided percutaneous biopsy. There was no occurrence of significant complication. We have experienced mild complications in only 5 patients-2 hematuria and 2 hematochezia in transrectal prostatic biopsy, and 1 minimal pneumothorax in CT-guided percutaneous lung biopsy. All of them were resolved spontaneously. The image-guided biopsy using the automated biopsy gun was a simple, safe and accurate method of obtaining adequate specimen for the histopathologic diagnosis

  11. Usefulness of automated biopsy guns in image-guided biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jung Hyung; Rhee, Chang Soo; Lee, Sung Moon; Kim, Hong; Woo, Sung Ku; Suh, Soo Jhi [School of Medicine, Keimyung University, Daegu (Korea, Republic of)

    1994-12-15

    To evaluate the usefulness of automated biopsy guns in image-guided biopsy of lung, liver, pancreas and other organs. Using automated biopsy devices, 160 biopsies of variable anatomic sites were performed: Biopsies were performed under ultrasonographic(US) guidance in 95 and computed tomographic (CT) guidance in 65. We retrospectively analyzed histologic results and complications. Specimens were adequate for histopathologic diagnosis in 143 of the 160 patients(89.4%)-Diagnostic tissue was obtained in 130 (81.3%), suggestive tissue obtained in 13(8.1%), and non-diagnostic tissue was obtained in 14(8.7%). Inadequate tissue was obtained in only 3(1.9%). There was no statistically significant difference between US-guided and CT-guided percutaneous biopsy. There was no occurrence of significant complication. We have experienced mild complications in only 5 patients-2 hematuria and 2 hematochezia in transrectal prostatic biopsy, and 1 minimal pneumothorax in CT-guided percutaneous lung biopsy. All of them were resolved spontaneously. The image-guided biopsy using the automated biopsy gun was a simple, safe and accurate method of obtaining adequate specimen for the histopathologic diagnosis.

  12. Post-treatment biopsy results following permanent transrectal ultrasound-guided interstitial brachytherapy in early stage prostate cancer

    International Nuclear Information System (INIS)

    Prestidge, Bradley R.; Blasko, John C.; Grimm, Peter D.; Hoak, David C.; Cavanagh, Bill; Ragde, Haakon

    1995-01-01

    PURPOSE/OBJECTIVE: Although some controversy remains, most authors agree that post-treatment prostatic biopsy is the best measure of local control in prostate cancer. Brachytherapy series reporting post-implant biopsy results have been few in number, limited in size, and involving older open or combined external beam techniques. The present study was undertaken to assess local control rates as determined by post-implant prostate biopsy in a large series of consecutive patients who have received permanent interstitial brachytherapy using a contemporary transrectal ultrasound directed, transperineal, computer generated, volume technique. METHOD/MATERIALS: From January 1988 to January 1994, 402 patients received permanent I-125 (285, 71%) or Pd-103 (117, 29%) interstitial brachytherapy as primary treatment for prostatic carcinoma at the Northwest Tumor Institute. Of these, 201 have consented to prostatic biopsy at least 12 months post-implant with a median follow-up of 40 months (range of 12 to 83 months). None had received hormone manipulation. A total of 361 biopsies were performed on 201 patients with a range of 1 to 6 yearly biopsies per patient; 91 receiving multiple biopsies. The other 201 patients were either unable (for geographic reasons) or unwilling to submit for biopsy. However, all patients with a rising PSA or clinical suspicion of recurrence underwent biopsy when possible. The 201 biopsy patients presented with a median age of 69 (range 47 to 89). Stages included 51 T1 (25%), 125 T2a (62%), 22 T2b (11%), and 3 T2c (1%). Gleason sums included 69 2-4 (34%), 117 5-6 (58%), 15 7-10 (7%), and 2 ungraded (1%). The initial PSA was 6.6 (range 0.7 to 74.6). There was no significant difference in the presenting characteristics or implant parameters between those patients biopsied and those that were not. 143 received I-125 (71%) prescribed to a minimum peripheral dose of 160 Gy with a median activity of 35.5 mCi, and 58 (29%) received Pd-103 prescribed to a

  13. CT-guided core-needle biopsy in omental pathology

    International Nuclear Information System (INIS)

    Pombo, F.; Rodriguez, E.; Martin, R.; Lago, M.

    1997-01-01

    Purpose: To assess the accuracy and clinical usefulness of CT-guided core-needle biopsy in the diagnosis of omental pathology. Material and Methods: We retrospectively reviewed the results of CT-guided percutaneous core biopsies in 25 patients with focal (n=2) or diffuse (n=23) omental pathology. These results were compared to the final diagnoses as determined by laparotomy (n=15), laparoscopic biopsy (n=3), endoscopic biopsy (n=1), or by the results of percutaneous biopsy and clinical-radiological and bacteriological modalities (n=6). The final diagnoses showed 4 patients with isolated omental pathology and 21 with widespread peritoneal involvement. The CT-guided biopsies were performed with 1.0=1.8-mm Surecut core-needles. Results: In 16 patients, the final diagnosis was metastatic adenocarcinoma - with the primary tumor sites in the ovary (n=3), stomach (n=1), appendix (n=2), and unknown (n=10). In the remaining 9 patients, the final diagnosis was hepatocellular carcinoma, lymphoma, and mesothelioma in 1 patient each; tuberculosis in 5; and actinomycosis in 1. Sufficient histological (n=16) or cytological (n=8) material was obtained by CT biopsy in 24/25 (96%) cases; the specimen was insufficient for diagnosis in 1 case. In differentiating benign from malignant disease, CT-guided biopsy showed a sensitivity, specificity and accuracy of respectively 89.5%, 100% and 92%. It gave a specific diagnosis in 78.9% (15/19) of patients with malignant conditions and in 50% (3/6) of patients with benign disorders. There were no biopsy-related complications. Conclusion: CT-guided percutaneous core-needle biopsy of the omentum is a safe, useful and highly accurate procedure for diagnosing malignant omental pathology. (orig.)

  14. CT fluoroscopy-guided vs. multislice CT biopsy mode-guided lung biopsies: Accuracy, complications and radiation dose

    International Nuclear Information System (INIS)

    Prosch, Helmut; Stadler, Alfred; Schilling, Matthias; Bürklin, Sandra; Eisenhuber, Edith; Schober, Ewald; Mostbeck, Gerhard

    2012-01-01

    Background: The aim of this retrospective study was to compare the diagnostic accuracy, the frequency of complications, the duration of the interventions and the radiation doses of CT fluoroscopy (CTF) guided biopsies of lung lesions with those of multislice CT (MS-CT) biopsy mode-guided biopsies. Methods: Data and images from 124 consecutive patients undergoing CTF-guided lung biopsy (group A) and 132 MS-CT-biopsy mode-guided lung biopsy (group B) were reviewed. CTF-guided biopsies were performed on a Siemens Emotion 6 CT scanner with intermittent or continuous CT-fluoroscopy, MS-CT biopsy mode-guided biopsies were performed on a Siemens Emotion 16 CT scanner. All biopsies were performed with a coaxial needle technique. Results: The two groups (A vs. B) did not differ significantly regarding sensitivity (95.5% vs. 95.9%), specificity (96.7% vs. 95.5%), negative predictive value (87.9% vs. 84%) or positive predictive value (98.8% vs. 98.9%). Pneumothorax was observed in 30.0% and 32.5% of the patients, respectively. Chest tube placement was necessary in 4% (group A) and 13% (group B) of the patients. The duration of the intervention was significantly longer in group A (median 37 min vs. 32 min, p = 0.04). The mean CT dose index (CTDI) was 422 in group A and 36.3 in group B (p < 0.001). Conclusion: Compared to CTF-guided biopsies, chest biopsies using the MS-CT biopsy mode show dramatically lower CTDI levels. Although the diagnostic yield of the procedures do not differ significantly, biopsies using the MS-CT-biopsy mode have a three-fold higher rate of chest tube placement.

  15. Biopsy

    Science.gov (United States)

    ... Oropharynx lesion biopsy Pleural needle biopsy Polyp biopsy Rectal biopsy Renal biopsy Salivary gland biopsy Skin lesion ... Copyright 1997-2018, A.D.A.M., Inc. Duplication for commercial use must be authorized in writing ...

  16. [Transthoracic needle-biopsy in coin-lesions of the lung-comparison of the results of different procedures (author's transl)].

    Science.gov (United States)

    Dürschmied, H; Polak, J

    1980-01-01

    This report deals with the results and the complications of transthoracic needle-biopsy performed with different methods at two cooperating hospitals (Prague and Bad Berka). Each hospital investigated 200 persons. As for tumours thin-needle biopsy yielded more positive results for tumours also more false positive results. As for other localized lung diseases the biopsy by means of a Hauser-needle was more successful.

  17. MR imaging-guided vacuum-assisted breast biopsy: Reduction of false-negative biopsies by short-term control MRI 24–48 h after biopsy

    International Nuclear Information System (INIS)

    Bahrs, S.D.; Hattermann, V.; Preibsch, H.; Hahn, M.; Staebler, A.; Claussen, C.D.; Siegmann-Luz, K.C.

    2014-01-01

    Aim: To evaluate whether another contrast-enhanced (CE) magnetic resonance imaging (MRI) examination 24–48 h after MRI-guided vacuum-assisted breast biopsy (MRI-VAB) can reduce the rate of false-negative cases. Materials and methods: The study included 252 patients who underwent MRI-VAB for the clarification of 299 lesions. The success of MRI-VAB was assessed at interventional MRI and another CE MRI 24–48 h after the intervention. In cases of successful MRI-VAB (complete or partial lesion removal) and benign histological results, follow-up breast MRI was performed. In cases of unsuccessful biopsy (unchanged lesion), tissue sampling was repeated. False-negative cases were calculated to assess the diagnostic value of MRI follow-up within 2 days after intervention. Results: Ninety-eight malignant (32.8%) and 201 (67.2%) benign lesions were diagnosed using MRI-VAB. At immediate unenhanced control MRI, all lesions were assessed as successfully biopsied. In 18 benign cases (6%), CE MRI after 24–48 h showed an unsuccessful intervention. Further tissue sampling revealed another 13 cancers in these patients. This results in a false-negative rate of 11.7%. Follow-up MRI of the benign lesions presented no further malignancy. Conclusions: MRI-VAB with immediate unenhanced control offers a success rate of 94%. The rate of false-negative biopsies (11.7%) could be reduced to zero by using short-term follow-up MRI. Therefore, a further CE breast MRI 24–48 h after benign MRI-VAB to eliminate missed cancers is recommended. - Highlights: • Some suspicious breast lesions are only seen on MRI. • They can be biopsied by a MRI-guided vacuum-assisted biopsy system. • Inadequate sampling causes some false-negative biopsies. • We evaluate an additional control MRI 24 to 48 hours after biopsy. • A reduced rate of the false-negative biopsies was found

  18. Robot-assisted biopsies in a high-field MRI system. First clinical results

    International Nuclear Information System (INIS)

    Schell, B.; Eichler, K.; Mack, M.G.; Mueller, C.; Kerl, J.M.; Beeres, M.; Thalhammer, A.; Vogl, T.J.; Zangos, S.; Czerny, C.

    2012-01-01

    Purpose: The purpose of this study was to examine the clinical use of MR-guided biopsies in patients with suspicious lesions using a new MR-compatible assistance system in a high-field MR system. Materials and Methods: Six patients with suspicious focal lesions in various anatomic regions underwent percutanous biopsy in a high-field MR system (1.5 T, Magnetom Espree, Siemens) using a new MR-compatible assistance system (Innomotion). The procedures were planned and guided using T1-weighted FLASH and TrueFISP sequences. A servopneumatic drive then moved the guiding arm automatically to the insertion point. An MRI compatible 15G biopsy system (Somatex) was introduced by a physician guided by the needle holder and multiple biopsies were performed using the coaxial technique. The feasibility, duration of the intervention and biopsy findings were analyzed. Results: The proposed new system allows accurate punctures in a high-field MR system. The assistance device did not interfere with the image quality, and guided the needle virtually exactly as planned. Histological examination could be conducted on every patient. The lesion was malignant in four cases, and an infectious etiology was diagnosed for the two remaining lesions. Regarding the differentiation of anatomical and pathological structures and position monitoring of the insertion needle, TrueFISP images are to be given preference. The average intervention time was 41 minutes. Lesions up to 15.4 cm beneath the skin surface were punctured. Conclusion: The proposed MR-guided assistance system can be successfully utilized in a high-field MR system for accurate punctures of even deep lesions in various anatomic regions. (orig.)

  19. Targeted MRI-guided prostate biopsy: are two biopsy cores per MRI-lesion required?

    Energy Technology Data Exchange (ETDEWEB)

    Schimmoeller, L.; Quentin, M.; Blondin, D.; Dietzel, F.; Schleich, C.; Thomas, C.; Antoch, G. [University Dusseldorf, Medical Faculty, Department of Diagnostic and Interventional Radiology, Dusseldorf (Germany); Hiester, A.; Rabenalt, R.; Albers, P.; Arsov, C. [University Dusseldorf, Medical Faculty, Department of Urology, Dusseldorf (Germany); Gabbert, H.E. [University Dusseldorf, Medical Faculty, Department of Pathology, Dusseldorf (Germany)

    2016-11-15

    This study evaluates the feasibility of performing less than two core biopsies per MRI-lesion when performing targeted MR-guided in-bore prostate biopsy. Retrospectively evaluated were 1545 biopsy cores of 774 intraprostatic lesions (two cores per lesion) in 290 patients (66 ± 7.8 years; median PSA 8.2 ng/ml) regarding prostate cancer (PCa) detection, Gleason score, and tumor infiltration of the first (FBC) compared to the second biopsy core (SBC). Biopsies were acquired under in-bore MR-guidance. For the biopsy cores, 491 were PCa positive, 239 of 774 (31 %) were FBC and 252 of 771 (33 %) were SBC (p = 0.4). Patient PCa detection rate based on the FBC vs. SBC were 46 % vs. 48 % (p = 0.6). For clinically significant PCa (Gleason score ≥4 + 3 = 7) the detection rate was 18 % for both, FBC and SBC (p = 0.9). Six hundred and eighty-seven SBC (89 %) showed no histologic difference. On the lesion level, 40 SBC detected PCa with negative FBC (7.5 %). Twenty SBC showed a Gleason upgrade from 3 + 3 = 6 to ≥3 + 4 = 7 (2.6 %) and 4 to ≥4 + 3 = 7 (0.5 %). The benefit of a second targeted biopsy core per suspicious MRI-lesion is likely minor, especially regarding PCa detection rate and significant Gleason upgrading. Therefore, a further reduction of biopsy cores is reasonable when performing a targeted MR-guided in-bore prostate biopsy. (orig.)

  20. Targeted MRI-guided prostate biopsy: are two biopsy cores per MRI-lesion required?

    International Nuclear Information System (INIS)

    Schimmoeller, L.; Quentin, M.; Blondin, D.; Dietzel, F.; Schleich, C.; Thomas, C.; Antoch, G.; Hiester, A.; Rabenalt, R.; Albers, P.; Arsov, C.; Gabbert, H.E.

    2016-01-01

    This study evaluates the feasibility of performing less than two core biopsies per MRI-lesion when performing targeted MR-guided in-bore prostate biopsy. Retrospectively evaluated were 1545 biopsy cores of 774 intraprostatic lesions (two cores per lesion) in 290 patients (66 ± 7.8 years; median PSA 8.2 ng/ml) regarding prostate cancer (PCa) detection, Gleason score, and tumor infiltration of the first (FBC) compared to the second biopsy core (SBC). Biopsies were acquired under in-bore MR-guidance. For the biopsy cores, 491 were PCa positive, 239 of 774 (31 %) were FBC and 252 of 771 (33 %) were SBC (p = 0.4). Patient PCa detection rate based on the FBC vs. SBC were 46 % vs. 48 % (p = 0.6). For clinically significant PCa (Gleason score ≥4 + 3 = 7) the detection rate was 18 % for both, FBC and SBC (p = 0.9). Six hundred and eighty-seven SBC (89 %) showed no histologic difference. On the lesion level, 40 SBC detected PCa with negative FBC (7.5 %). Twenty SBC showed a Gleason upgrade from 3 + 3 = 6 to ≥3 + 4 = 7 (2.6 %) and 4 to ≥4 + 3 = 7 (0.5 %). The benefit of a second targeted biopsy core per suspicious MRI-lesion is likely minor, especially regarding PCa detection rate and significant Gleason upgrading. Therefore, a further reduction of biopsy cores is reasonable when performing a targeted MR-guided in-bore prostate biopsy. (orig.)

  1. Indications and results of renal biopsy in children: a 36-year experience.

    Science.gov (United States)

    Santangelo, Luisa; Netti, Giuseppe Stefano; Giordano, Paolo; Carbone, Vincenza; Martino, Marida; Torres, Diletta Domenica; Rossini, Michele; Di Palma, Anna Maria; Gesualdo, Loreto; Giordano, Mario

    2018-04-01

    This study was conducted to investigate retrospectively the indications for renal biopsy (RB) in native kidneys and to analyze pathological findings in a single tertiary pediatric hospital in Southern Italy for the last 36 years. All patients who underwent RB at our hospital from 1979 to 2014 were included. All renal tissue specimens were studied under light and immunofluorescent microscopy, while electron microscopy was performed only for specific clinical indications. The study group included 213 patients (female 43.2%) who underwent 225 percutaneous native kidney biopsies. Median age was 10.4 years (range 0.6-24 years). The most frequent indication for RB was nephrotic syndrome (44.4%), followed by proteinuria (27.6%), asymptomatic hematuria (17.3%) and acute kidney injury (9.8%). Gross hematuria appeared after biopsy in less than 5% of the patients, but none of them needed blood transfusion. Adequate renal tissue sample was obtained in 95.5% of the renal biopsies. Primary glomerulonephritis (GN) was the most common finding (61.4%), followed by secondary GN (21.4%), tubulointerstitial diseases (3.7%) and hereditary nephropathy (2.8%), while in 10.7% of the cases, normal renal tissues were found. According to histopathological diagnosis, the most common causes of primary GN were IgA nephropathy (20.9%), followed by minimal change disease (18.1%) and focal segmental glomerulosclerosis (11.6%). The epidemiology of glomerular disease in our single-center cohort is similar to that shown in other national and international reports. Moreover, our study shows that percutaneous ultrasound-guided RB is a safe, reliable and effective technique in children.

  2. A study to evaluate the efficacy of image-guided core biopsy in the diagnosis and management of lymphoma-Results in 103 biopsies

    International Nuclear Information System (INIS)

    Vandervelde, C.; Kamani, T.; Varghese, A.; Ramesar, K.; Grace, R.; Howlett, D.C.

    2008-01-01

    The reason for this study was to evaluate the ability of image-guided core biopsy to replace surgical excision by providing sufficient diagnostic and treatment information. All consecutive image-guided core biopsies in patients with a final diagnosis of lymphoma over a 6-year period at our institution were collected retrospectively. Case notes and pathology reports were reviewed and the diagnostic techniques used were recorded. Pathology reports were graded according to their diagnostic completeness and their ability to provide treatment information. Out of a total of 328 instances of lymphoma, 103 image-guided core biopsies were performed in 96 patients. In 78% of these, the diagnostic information obtained from the biopsy provided a fully graded and subtyped diagnosis of lymphoma with sufficient information to initiate therapy. In the head and neck 67% of core biopsies were fully diagnostic for treatment purposes compared to 91% in the thorax, abdomen and pelvis. Image-guided core biopsy has a number of cost and safety advantages over surgical excision biopsy and in suitable cases it can obviate the need for surgery in cases of suspected lymphoma. This is especially relevant for elderly patients and those with poor performance status

  3. A study to evaluate the efficacy of image-guided core biopsy in the diagnosis and management of lymphoma-Results in 103 biopsies

    Energy Technology Data Exchange (ETDEWEB)

    Vandervelde, C. [Department of Radiology, Eastbourne District General Hospital, Kings Drive, Eastbourne, East Sussex BN21 2UD (United Kingdom)], E-mail: clivevandervelde@gmail.com; Kamani, T. [Department of ENT Surgery, Eastbourne District General Hospital, Kings Drive, Eastbourne, East Sussex BN21 2UD (United Kingdom)], E-mail: tkamany@yahoo.com; Varghese, A. [Department of Radiology, Eastbourne District General Hospital, Kings Drive, Eastbourne, East Sussex BN21 2UD (United Kingdom)], E-mail: vargheseajay@hotmail.com; Ramesar, K. [Department of Histopathology, Eastbourne District General Hospital, Kings Drive, Eastbourne, East Sussex BN21 2UD (United Kingdom)], E-mail: keith.ramesar@esht.nhs.uk; Grace, R. [Department of Haematology, Eastbourne District General Hospital, Kings Drive, Eastbourne, East Sussex BN21 2UD (United Kingdom)], E-mail: richard.grace@esht.nhs.uk; Howlett, D.C. [Department of Radiology, Eastbourne District General Hospital, Kings Drive, Eastbourne, East Sussex BN21 2UD (United Kingdom)], E-mail: david.howlett@esht.nhs.uk

    2008-04-15

    The reason for this study was to evaluate the ability of image-guided core biopsy to replace surgical excision by providing sufficient diagnostic and treatment information. All consecutive image-guided core biopsies in patients with a final diagnosis of lymphoma over a 6-year period at our institution were collected retrospectively. Case notes and pathology reports were reviewed and the diagnostic techniques used were recorded. Pathology reports were graded according to their diagnostic completeness and their ability to provide treatment information. Out of a total of 328 instances of lymphoma, 103 image-guided core biopsies were performed in 96 patients. In 78% of these, the diagnostic information obtained from the biopsy provided a fully graded and subtyped diagnosis of lymphoma with sufficient information to initiate therapy. In the head and neck 67% of core biopsies were fully diagnostic for treatment purposes compared to 91% in the thorax, abdomen and pelvis. Image-guided core biopsy has a number of cost and safety advantages over surgical excision biopsy and in suitable cases it can obviate the need for surgery in cases of suspected lymphoma. This is especially relevant for elderly patients and those with poor performance status.

  4. Does a previous prostate biopsy-related acute bacterial prostatitis affect the results of radical prostatectomy?

    Directory of Open Access Journals (Sweden)

    Hakan Türk

    Full Text Available ABSTRACT Objective To The standard technique for obtaining a histologic diagnosis of prostatic carcinomas is transrectal ultrasound guided prostate biopsy. Acute prostatitis which might develop after prostate biopsy can cause periprostatic inflammation and fibrosis. In this study, we performed a retrospective review of our database to determine whether ABP history might affect the outcome of RP. Materials and Methods 441 RP patients who were operated in our clinic from 2002 to 2014 were included in our study group. All patients’ demographic values, PSA levels, biopsy and radical prostatectomy specimen pathology results and their perioperative/ postoperative complications were evaluated. Results There were 41 patients in patients with acute prostatitis following biopsy and 397 patients that did not develop acute prostatitis. Mean blood loss, transfusion rate and operation period were found to be significantly higher in ABP patients. Hospitalization period and reoperation rates were similar in both groups. However, post-op complications were significantly higher in ABP group. Conclusion Even though it does not affect oncological outcomes, we would like to warn the surgeons for potential complaints during surgery in ABP patients.

  5. Clinical impact of bladder biopsies with TUR-BT according to cytology results in patients with bladder cancer: a case control study

    Directory of Open Access Journals (Sweden)

    Matsumoto Kazuhiro

    2010-06-01

    Full Text Available Abstract Background There seems to be no consensus concerning taking bladder biopsies during transurethral resection of bladder tumor (TUR-BT. We investigate the clinical significance of bladder biopsy with TUR-BT and the relationship between urinary cytology and the biopsy results. Methods We reviewed a total of 424 patients with non-muscle invasive bladder cancer treated with TUR-BT between 1998 and 2005. Of the total, 293 patients also underwent a bladder biopsy. Biopsies from suspicious-appearing urothelium (N = 59 and those from normal-appearing urothelium (N = 234 were evaluated separately. Results Bladder cancer was observed in 23 cases (39.0% who underwent a biopsy of suspicious-appearing urothelium. Among these 23 cases, 9 cases with visible tumor resection had carcinoma in situ (CIS only in the biopsies from suspicious-appearing urothelium. Urinary cytology was negative in 3 of the 9 cases. Bladder cancer was observed in 26 cases (11.1% who underwent a biopsy of normal-appearing urothelium. Of them, 5 cases with visible tumors had CIS only in the multiple biopsies from normal-appearing urothelium. Urinary cytology was positive in all of the 5 cases. No upstaging or upgrading cases were found in these patients by the addition of these two types of biopsy. Furthermore, therapy was not altered in these patients. With or without bladder biopsy was not a significant factor for tumor recurrence in either the univariate or multivariate analysis. Conclusions Based on the results, it is concluded the multiple biopsies from normal-appearing urothelium are not necessary in patients with negative cytology results because of the low detection rate and lack of influence on therapeutic decisions. Meanwhile, biopsy of suspicious-appearing urothelium is needed in patients with negative cytology results in order to detect CIS due to staging properties. This result supports a recent EAU guideline.

  6. Percutaneous fine needle aspiration biopsy for the intrathoracic lesions: What is the meaning of non-diagnostic results?

    International Nuclear Information System (INIS)

    Kim, Min Ju; Lee, Jin Seong; Do, Kyung Hyun; Seo, Joon Beom; Song, Koun Sik; Lim, Tae Hwan

    2003-01-01

    To know what is the meaning of non-diagnostic results of fine needle aspiration biopsy (FNAB) and whether repeated aspiration is needed or not in those situations. We reviewed 1845 patients who underwent FNAB from 1997 to 2001. Non-diagnostic results of the first FNAB were divided into four groups: insufficient number of cells, inflammatory cells, necrotic debris and atypical cells. We analyzed final diagnosis of 531 patients who had non-diagnostic results from the first FNAB. Among them, 207 lesions were re-biopsied because of clinical and radiologic suspicion of malignancy. The diagnostic yield of repeated FNAB was analyzed and compared with the results of the first FNAB. Among 255 cases with 'inflammatory cells only' results, 120 cases were confirmed benignancy on follow-up. Twenty nine of 50 stypical cells (58%) were malignant of follow-up. One hundred one of 207 repeated FNAB resulted in the non-diagnostic reports, and 106 of 207 repeated FNAB were diagnosed as specific diagnosis. Among thirty lesions showing atypical cells on the repeated FNAB, 22 (73%) were identified as malignant neoplasms. When the specimen of FNAB shows atypical cells, the possibility of malignancy is very high. When the results of FNAB is non-diagnostic in the cases with clinical and radiological suspicion of malignancy, repeated FNAB procedures should be seriously considered and will be helpful for accurate specific diagnosis

  7. Biopsy in Musculoskeletal Tumors

    Directory of Open Access Journals (Sweden)

    Mohammad Gharehdaghi

    2014-09-01

    Full Text Available Diagnosis of bone tumors is based on careful evaluation of clinical, imaging and a pathologic findings. So the biopsy of bone and soft tissue sarcomas is the final step in evaluation and a fundamental step in the diagnosis of the lesion. It should not be performed as a shortcut to diagnosis (1. The biopsy should be performed in order to confirm the diagnosis and differentiate among few diagnoses after careful staged studies. Real and artificial changes in imaging studies will be superimposed after performing biopsy, which may alter the interpretation if done after biopsy is taken (1. The correct management of a sarcoma depends on the accurate diagnosis. Inadequate, inapprppriate, or inaccurate non-representative biopsy leads to poorer outcome in terms of survivorship and limb salvage. An incorrect, unplanned incision and biopsy may unnecessarily contaminate uninvolved compartments which may convert a salvageable limb to amputation. Anatomic approach along with the proper biopsy techniques may lead to success or catastrophe. It is clear that in patients with inappropriate biopsy, the chance of the need to change the treatment to more radical than would originally be expected is significantly higher. Also it is more probable to need to  convert curative to palliative treatment and to require adjuvant radiotherapy in patients with inappropriate biopsies. Patients with sarcoma are best served by early referral to a specialized center where staged investigations and biopsy can be performed with minimal morbidity (3. Open biopsy is still considered the gold standard; however, recent studies suggest comparable results with percutaneous core needle biopsy. Our study on 103 consecutive CNB and open biopsy showed comparable results as well. Surgeons need to answer to two questions prior to performing a biopsy: 1-          Where is the best part of the lesion to be biopsied? 2-          What is the safest route without contaminating

  8. Accuracy of percutaneous lung biopsy for invasive pulmonary aspergillosis

    Energy Technology Data Exchange (ETDEWEB)

    Hoffer, F.A. [Dept. of Diagnostic Imaging, St. Jude Children' s Research Hospital, Memphis, TN (United States); Gow, K.; Davidoff, A. [Dept. of Surgery, St. Jude Children' s Research Hospital, Memphis, TN (United States); Flynn, P.M. [Dept. of Infectious Diseases, St. Jude Children' s Research Hospital, Memphis, TN (United States)

    2001-03-01

    Background. Invasive pulmonary aspergillosis is fulminant and often fatal in immunosuppressed patients. Percutaneous biopsy may select patients who could benefit from surgical resection. Objective. We sought to determine the accuracy of percutaneous biopsy for pediatric invasive pulmonary aspergillosis. Materials and methods. We retrospectively reviewed 28 imaging-guided percutaneous biopsies of the lungs of 24 children with suspected pulmonary aspergillosis. Twenty-two were being treated for malignancy and two for congenital immunodeficiency; 15 had received bone-marrow transplants. The accuracy of the percutaneous lung biopsy was determined by subsequent surgical resection, autopsy, or clinical course. Results. Histopathological studies showed ten biopsy specimens with septate hyphae, indicating a mold, and seven with Aspergillus flavus colonies in culture. The remaining 18 biopsies revealed no fungi. No patient had progressive aspergillosis after negative biopsy. Invasive pulmonary mold was detected by percutaneous biopsy with 100 % (10/10) sensitivity and 100 % (18/18) specificity. Percutaneous biopsy results influenced the surgical decision in 86 % (24 of 28) of the cases. Bleeding complicated the biopsy in 46 % (13/28) and hastened one death. Conclusion. Percutaneous biopsy of the lung is an accurate technique for the diagnosis of invasive pulmonary aspergillosis and correctly determines which immunosuppressed pediatric patients would benefit from therapeutic pulmonary resection. (orig.)

  9. Accuracy of percutaneous lung biopsy for invasive pulmonary aspergillosis

    International Nuclear Information System (INIS)

    Hoffer, F.A.; Gow, K.; Davidoff, A.; Flynn, P.M.

    2001-01-01

    Background. Invasive pulmonary aspergillosis is fulminant and often fatal in immunosuppressed patients. Percutaneous biopsy may select patients who could benefit from surgical resection. Objective. We sought to determine the accuracy of percutaneous biopsy for pediatric invasive pulmonary aspergillosis. Materials and methods. We retrospectively reviewed 28 imaging-guided percutaneous biopsies of the lungs of 24 children with suspected pulmonary aspergillosis. Twenty-two were being treated for malignancy and two for congenital immunodeficiency; 15 had received bone-marrow transplants. The accuracy of the percutaneous lung biopsy was determined by subsequent surgical resection, autopsy, or clinical course. Results. Histopathological studies showed ten biopsy specimens with septate hyphae, indicating a mold, and seven with Aspergillus flavus colonies in culture. The remaining 18 biopsies revealed no fungi. No patient had progressive aspergillosis after negative biopsy. Invasive pulmonary mold was detected by percutaneous biopsy with 100 % (10/10) sensitivity and 100 % (18/18) specificity. Percutaneous biopsy results influenced the surgical decision in 86 % (24 of 28) of the cases. Bleeding complicated the biopsy in 46 % (13/28) and hastened one death. Conclusion. Percutaneous biopsy of the lung is an accurate technique for the diagnosis of invasive pulmonary aspergillosis and correctly determines which immunosuppressed pediatric patients would benefit from therapeutic pulmonary resection. (orig.)

  10. The results of transrectal prostate biopsy in patients with low levels of prostate specific antigen

    Directory of Open Access Journals (Sweden)

    Ahmet Ali Sancaktutar

    2012-06-01

    Full Text Available Objectives: The aim of this study is to evaluate the resultsof prostate biopsy of patients who had the prostatespecificantigen (PSA levels below 4 ng/ml.Material and methods: The medical records of 63 patientswho underwent transrectal prostate biopsy, betweenJanuary 2005 and December 2011, due to suspicionof prostate cancer with the PSA levels under 4 ng/mlwere retrospectively reviewed.Results: Transrectal Prostate biopsy was performed to63 patients. Prostate cancer was detected in 12 (19%patients. The mean value of PSA was 2.5 ng/ml. TheGleason score of Prostate cancer patients was 6,8 (5-7and the number of positive cores were 3.Conclusions: The rate of prostate cancer was found as19% in patients with levels of PSA under 4 ng/ml and thisratio is compatible with the results of previous reports.

  11. Breast Biopsy: The Effects of Hypnosis and Music.

    Science.gov (United States)

    Téllez, Arnoldo; Sánchez-Jáuregui, Teresa; Juárez-García, Dehisy M; García-Solís, Manuel

    2016-01-01

    The authors evaluated the efficacies of audio-recorded hypnosis with background music and music without hypnosis in the reduction of emotional and physical disturbances in patients scheduled for breast biopsy in comparison with a control group. A total of 75 patients were randomly assigned to 3 different groups and evaluated at baseline and before and after breast biopsy using visual analog scales of stress, pain, depression, anxiety, fatigue, optimism, and general well-being. The results showed that, before breast biopsy, the music group presented less stress and anxiety, whereas the hypnosis with music group presented reduced stress, anxiety, and depression and increased optimism and general well-being. After the biopsy, the music group presented less anxiety and pain, whereas the hypnosis group showed less anxiety and increased optimism.

  12. Percutaneous CT-guided needle biopsies of musculoskeletal tumors: a 5-year analysis of non-diagnostic biopsies

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Connie Y.; Huang, Ambrose J.; Bredella, Miriam A.; Torriani, Martin; Rosenthal, Daniel I. [Massachusetts General Hospital, Division of Musculoskeletal Imaging and Intervention, Department of Radiology, Boston, MA (United States); Halpern, Elkan F. [Massachusetts General Hospital, Institute for Technology Assessment, Department of Radiology, Boston, MA (United States); Springfield, Dempsey S. [Massachusetts General Hospital, Department of Orthopedics, Boston, MA (United States)

    2015-12-15

    To study non-diagnostic CT-guided musculoskeletal biopsies and take steps to minimize them. Specifically we asked: (1) What malignant diagnoses have a higher non-diagnostic rate? (2) What factors of a non-diagnostic biopsy may warrant more aggressive pursuit? (3) Do intra-procedural frozen pathology (FP) or point-of-care (POC) cytology reduce the non-diagnostic biopsy rate ?This study was IRB-approved and HIPAA-compliant. We retrospectively reviewed 963 consecutive CT-guided musculoskeletal biopsies. We categorized pathology results as malignant, benign, or non-diagnostic and recorded use of FP or POC cytology. Initial biopsy indication, final diagnosis, method of obtaining the final diagnosis of non-diagnostic biopsies, age of the patient, and years of biopsy attending experience were recorded. Groups were compared using Pearson's χ{sup 2} test or Fisher's exact test. In all, 140 of 963 (15 %) biopsies were non-diagnostic. Lymphoma resulted in more non-diagnostic biopsies (P < 0.0001). While 67% of non-diagnostic biopsies yielded benign diagnoses, 33% yielded malignant diagnoses. Patients whose percutaneous biopsy was indicated due to the clinical context without malignancy history almost always generated benign results (96 %). Whereas 56% of biopsies whose indication was an imaging finding of a treatable lesion were malignant, 20% of biopsies whose indication was a history of malignancy were malignant. There was no statistically significant difference in the nondiagnostic biopsy rates of pediatric versus adult patients (P = 0.8) and of biopsy attendings with fewer versus more years of experience (P = 0.5). The non-diagnostic rates of biopsies with FP (8 %), POC cytology (25 %), or neither (24 %) were significantly different (P < 0.0001). Lymphoma is the malignant diagnosis most likely to result in a non-diagnostic biopsy. If the clinical and radiologic suspicion for malignancy is high, repeat biopsy is warranted. If the clinical context suggests a

  13. Percutaneous CT-guided needle biopsies of musculoskeletal tumors: a 5-year analysis of non-diagnostic biopsies

    International Nuclear Information System (INIS)

    Chang, Connie Y.; Huang, Ambrose J.; Bredella, Miriam A.; Torriani, Martin; Rosenthal, Daniel I.; Halpern, Elkan F.; Springfield, Dempsey S.

    2015-01-01

    To study non-diagnostic CT-guided musculoskeletal biopsies and take steps to minimize them. Specifically we asked: (1) What malignant diagnoses have a higher non-diagnostic rate? (2) What factors of a non-diagnostic biopsy may warrant more aggressive pursuit? (3) Do intra-procedural frozen pathology (FP) or point-of-care (POC) cytology reduce the non-diagnostic biopsy rate ?This study was IRB-approved and HIPAA-compliant. We retrospectively reviewed 963 consecutive CT-guided musculoskeletal biopsies. We categorized pathology results as malignant, benign, or non-diagnostic and recorded use of FP or POC cytology. Initial biopsy indication, final diagnosis, method of obtaining the final diagnosis of non-diagnostic biopsies, age of the patient, and years of biopsy attending experience were recorded. Groups were compared using Pearson's χ 2 test or Fisher's exact test. In all, 140 of 963 (15 %) biopsies were non-diagnostic. Lymphoma resulted in more non-diagnostic biopsies (P < 0.0001). While 67% of non-diagnostic biopsies yielded benign diagnoses, 33% yielded malignant diagnoses. Patients whose percutaneous biopsy was indicated due to the clinical context without malignancy history almost always generated benign results (96 %). Whereas 56% of biopsies whose indication was an imaging finding of a treatable lesion were malignant, 20% of biopsies whose indication was a history of malignancy were malignant. There was no statistically significant difference in the nondiagnostic biopsy rates of pediatric versus adult patients (P = 0.8) and of biopsy attendings with fewer versus more years of experience (P = 0.5). The non-diagnostic rates of biopsies with FP (8 %), POC cytology (25 %), or neither (24 %) were significantly different (P < 0.0001). Lymphoma is the malignant diagnosis most likely to result in a non-diagnostic biopsy. If the clinical and radiologic suspicion for malignancy is high, repeat biopsy is warranted. If the clinical context suggests a benign

  14. Temporal artery biopsies in south-east Scotland: a five year review.

    Science.gov (United States)

    Gajree, S; Borooah, S; Dhillon, N; Goudie, C; Smith, C; Aspinall, P; Dhillon, B

    2017-06-01

    Temporal artery biopsy is the gold standard investigation for the diagnosis of giant cell arteritis. The aim of this retrospective study was to investigate the use of temporal artery biopsy in diagnosing giant cell arteritis in south-east Scotland over a five-year period. We aimed to quantify success rates, and predictive factors for a positive biopsy, as well as compare the different specialities performing the biopsies. The data should enable the development of better criteria for referral for investigation of giant cell arteritis. Methods Patients were identified using a database of temporal artery biopsies generated by the pathology department in NHS Lothian (south east Scotland), for all biopsies examined between January 2010 and December 2015. An electronic patient record was used to retrospectively examine the records of patients in the database. Results A total of 715 biopsies were included in the study, of which 250 (35.0%) showed features of giant cell arteritis. The main predictors for a positive biopsy were age at biopsy, specialty performing biopsy, erythrocyte sedimentation rate, jaw claudication/pain, and ophthalmic symptoms. The most important predictor of a positive biopsy was erythrocyte sedimentation rate. The length of biopsy was not found to be a predictor of positive biopsy; however, diameter of biopsy was predictive. Conclusions We have shown that many temporal artery biopsies are negative, and finding ways to reduce the number of patients unnecessarily undergoing biopsy will be essential in reducing workload and streamlining services. This study demonstrates some key predictive factors for patients with positive biopsies. The study also shows that a large proportion of biopsies taking place do not result in the recommended length of specimen, but this does not necessarily reduce the likelihood of a positive biopsy.

  15. Transrectal ultrasound: Diagnosis of prostate cancer by a new biplane US-guided biopsy technique. Comparison of thin-needle cytology and histology with large-core biopsy

    International Nuclear Information System (INIS)

    Lee, F.; Littrup, P.; McLeary, R.; Kumasaka, G.; Borlaza, G.; McHugh, T.; Soiderer, M.; Roi, L.

    1986-01-01

    A new transperineal biopsy technique was developed that uses biplane transrectal US guidance for needle placement into anechoic-hypoechoic lesions thought to indicate prostate cancer (n = 83). The results of histologic studies on biopsy material obtained with a 22-gauge needle and of aspiration histologic studies on biopsy material obtained with a 19-gauge needle were compared with results of histologic studies on material obtained with a 14-gauge needle. When sufficient tissue was obtained, the positive biopsy yield was 61% by cytology and 58% by histology; the combined yield was 61%. A limited study ( n = 21) of histologic findings in biopsy material obtained with 19-gauge and 14-gauge needles showed equivalent diagnostic results. Sixty-seven percent of the biopsies were of lesions less than 1.5 cm in diameter, and 57% (13 of 23) of the biopsy-proved cancers in this group were either nonpalpable or only mildly suspicious on digital rectal examination

  16. Fluoroscopy-guided transnasal biopsy of nasopharyngeal carcinoma using a flexible bronchoscopic biopsy forcep

    International Nuclear Information System (INIS)

    Kim, Jai Keun; Chung, Tae Sub; Kim, Dong Ik; Suh, Jung Ho

    1996-01-01

    Otolaryngoscopic biopsy of nasopharyngeal carcinoma is a generalized method which may be associated with inadequate sampling of tissue and patient discomfort. So, we tried fluoroscopy-guided transnasal biopsy using bronchoscopic biopsy forcep and evaluated its safety and efficacy. Prospectively we performed fluoroscopy-guided transnasal biopsy in 11 patients who were radiographically suspected of nasopharyngeal carcinoma. The posterior wall of the nasopharynx was coated with barium sulfate under fluoroscopy. A flexible bronchoscopic biopsy forcep with a steerable guiding catheter which was used in removal of intrahepatic duct stones was inserted through the nare. After localization of the tip of the biopsy forcep at tumor site with fluoroscopy, a tissue specimen was obtained. We also tried CT guided biopsy in initial 2cases. Each patient had otolaryngoscopic biopsy to compare the biopsy result and patient discomfort. We could have sufficient amount of tissue for pathological evaluation in 10 of 11 patients by the first pass with the fluoroscopic technique. Contrarily, otolaryngoscopic biopsy was successful in 7 of 11 patients on single passage. Additionally, 2 patients had complaint in our method comparing with 9 patients in otolaryngoscopic biopsy. Fluoroscopy-guided transnasal biopsy of nasopharyngeal carcinoma using the bronchoscopic biopsy forcep is safe and accurate. It can be a appropriate method competing otolaryngoscopic biopsy

  17. Optimal combinations for detection of prostate cancer: systematic sextant and laterally directed biopsies versus systematic sextant and color Doppler-targeted biopsies.

    Science.gov (United States)

    Kravchick, Sergey; Cytron, Shmuel; Peled, Ronit; London, Daniel; Sibi, Yosef; Ben-Dor, David

    2004-02-01

    To determine the accuracy of different combinations of biopsies in detecting prostate cancer. The standard sextant protocol for obtaining prostate biopsy underestimates the presence of prostate cancer. Conversely, an increased cancer detection rate has been obtained with additional laterally directed biopsies. The results of the studies dedicated to transrectal color Doppler (CD) sonography have shown that it might detect neoplastic lesions with no corresponding gray-scale abnormality. A total of 120 consecutive patients underwent sextant biopsy with additional biopsy cores taken from the lateral peripheral zone (four to six cores, depending on the prostate volume) and CD-guided biopsy. The sensitivity of laterally directed, CD-guided, and different combinations of biopsies was compared. Various patient, clinical, and pathologic factors were compared, and multivariate analysis was performed to assess the strongest predictor of cancer detection. Cancer was detected in 43 (35.8%) of 120 patients. The combination of sextant biopsy with laterally directed cores gained sensitivity to 56.6% compared with 67.4% obtained in the regimen that combined sextant and CD-guided biopsy. The CD regimen detected cancer in 11 additional patients. However, the differences in the detection rates of these combinations were not statistically significant (P = 0.797). The results of multivariate analysis showed that sextant biopsy and laterally directed cores were the strongest predictors of cancer detection (odds ratio 8.356 versus 49.282; 95% confidence interval 1.698 to 41.114 versus 10.508 to 231.130). The regimen that included sextant and CD-guided biopsy was the most sensitive. However, only standard sextant and laterally directed biopsies were statistically significant predictors of cancer detection on biopsy.

  18. Percutaneous biopsy of a metastatic common iliac lymph node using hydrodissection and a semi-automated biopsy gun

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, Seong Yoon; Park, Byung Kwan [Dept. of Radiology, amsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2017-06-15

    Percutaneous biopsy is a less invasive technique for sampling the tissue than laparoscopic biopsy or exploratory laparotomy. However, it is difficult to perform biopsy of a deep-seated lesion because of the possibility of damage to the critical organs. Recently, we successfully performed CT-guided biopsy of a metastatic common iliac lymph node using hydrodissection and semi-automated biopsy devices. The purpose of this case report was to show how to perform hydrodissection and how to use a semi-automated gun for safe biopsy of a metastatic common iliac lymph node.

  19. Automated gun biopsy of the prostate under ultrasound guide

    International Nuclear Information System (INIS)

    Yang, Ik; Lim, Jae Hoon; Ko, Young Tae; Lee, Dong Ho; Lim, Joo Won

    1994-01-01

    To assess the effectiveness and clinical usefulness of prostate biopsy by automated gun biopsy device under the transrectal ultrasonographic guidance, authors analysed the result of biopsy and the patients status after biopsy procedure. The subjects consisted of 24 patients with prostatic disease. Biopsy instrument was an automated gun biopsy device loaded with an 18 gauze biopsy needle. All the patients were admitted to the hospital. No analgesics was given. All the procedure was performed with the patient in left lateral decubitus. Biopsy was performed at 2-4 different points of the prostate in 22 cases, but recently, six different points were targeted in two patients. Biopsy specimens were sufficient in 21 cases but insufficient in three cases. Histologic examination of biopsy specimens showed that 13 cases were nodular hyperplasia, eight cases were cancerous and three cases were inflammation. There was no clinically significant complication. There was mild to moderate degree of pain in all patients. Tansrectal biopsy of the prostate with an automated gun biopsy device under ultrasonographic guidance is considered relatively easy, handy and useful procedure in patients with prostatic disease. The procedure may be performed on the out patient basis

  20. EFFICACY OF IMMUNOHISTOCHEMISTRY IN PROSTATE NEEDLE BIOPSIES

    Directory of Open Access Journals (Sweden)

    Tameem Afroz

    2016-10-01

    Full Text Available BACKGROUND Prostate needle biopsies can pose a major diagnostic challenge when it comes to differentiating adenocarcinoma and its variants from its benign mimics. In needle biopsies, when the suspicious focus is small, morphological features may not suffice to differentiate it from its morphologic mimics like atrophy, basal cell hyperplasia, reactive inflammatory changes, seminal vesicles and adenosis. Immunohistochemical marker for basal cells, p63 and prostate cancer specific marker, Alpha-Methylacyl-CoA Racemase (AMACR help in overcoming such diagnostic dilemmas. MATERIALS AND METHODS We analysed 157 prostate core needle biopsies over a period of 2 years. Routine Hematoxylin and Eosin (H and E sections and immunohistochemical markers for basal cells (p63 and prostate cancer specific marker (AMACR were used. Prospective study was done on prostate needle core biopsies. Biopsy was done under ultrasound guidance with an 18-gauge needle. Biopsy was done in patients with raised serum PSA levels for exclusion of prostate carcinoma. RESULTS Over a period of two years, 157 prostate core needle biopsies were studied. 83 were benign lesions comprising 69 benign prostatic hyperplasias, five basal cell hyperplasias, four granulomatous lesions and three showed atrophic changes. Two biopsies morphologically resembled seminal vesicles. Prostate cancer specific marker, AMACR was negative in all, but two lesions. In these two lesions, it showed weak nonspecific staining. Basal cell marker p63 showed a continuous staining pattern highlighting the basal cells in all the 69 cases of benign prostatic hyperplasia, 5 cases of basal hyperplasia showed positivity in all the hyperplastic basal cells. In the two cases of seminal vesicles, it showed intense basal cell positivity. It showed a discontinuous pattern in two of the four granulomatous lesions and showed a weak, but a continuous staining pattern in the atrophic lesions. 74 were adenocarcinomas; the predominant

  1. Does a previous prostate biopsy-related acute bacterial prostatitis affect the results of radical prostatectomy?

    Science.gov (United States)

    Türk, Hakan; Ün, Sitki; Arslan, Erkan; Zorlu, Ferruh

    2018-01-01

    To The standard technique for obtaining a histologic diagnosis of prostatic carcinomas is transrectal ultrasound guided prostate biopsy. Acute prostatitis which might develop after prostate biopsy can cause periprostatic inflammation and fibrosis. In this study, we performed a retrospective review of our database to determine whether ABP history might affect the outcome of RP. 441 RP patients who were operated in our clinic from 2002 to 2014 were included in our study group. All patients' demographic values, PSA levels, biopsy and radical prostatectomy specimen pathology results and their perioperative/postoperative complications were evaluated. There were 41 patients in patients with acute prostatitis following biopsy and 397 patients that did not develop acute prostatitis. Mean blood loss, transfusion rate and operation period were found to be significantly higher in ABP patients. Hospitalization period and reoperation rates were similar in both groups. However, post-op complications were significantly higher in ABP group. Even though it does not affect oncological outcomes, we would like to warn the surgeons for potential complaints during surgery in ABP patients. Copyright® by the International Brazilian Journal of Urology.

  2. Widespread high grade prostatic intraepithelial neoplasia on biopsy predicts the risk of prostate cancer: A 12 months analysis after three consecutive prostate biopsies

    Directory of Open Access Journals (Sweden)

    Cosimo De Nunzio

    2013-06-01

    Full Text Available Purpose: To evaluate the risk of prostate cancer (PCa on a third prostate biopsy in a group of patients with two consecutive diagnoses of high grade intraepithelial neoplasia (HGPIN. Materials and methods: From November 2004 to December 2007, patients referred to our clinic with a PSA ! 4 ng/ml or an abnormal digital rectal examination (DRE were scheduled for trans-rectal ultrasound (TRUS guided 12-core prostate biopsy. Patients with HGPIN underwent a second prostate biopsy, and if the results of such procedure yielded a second diagnosis of HGPIN, we proposed a third 12-core needle biopsy regardless of PSA value. Crude and adjusted logistic regressions were used to assess predictors of PCa on the third biopsy. Results: A total of 650 patients underwent 12 cores transrectal ultrasound prostatic biopsy in the study period. Of 147 (22% men with a diagnosis of HGPIN, 117 underwent a second prostatic biopsy after six months and 43 a third biopsy after other six months. After the third biopsy, 19 patients (34% still showed HGPIN, 15 (35% were diagnosed with PCa and 9 (21% presented with chronic prostatitis. Widespread HGPIN on a second biopsy was significantly associated with PCa on further biopsy (!2 = 4.04, p = 0.04. Moreover, the presence of widespread HGPIN significantly predicted the risk of PCa on crude and adjusted logistic regressions. Conclusions: Widespread HGPIN on second biopsy is associated with the presence of PCa on a third biopsy. Nonetheless, the relationship between HGPIN and PCa remains complex and further studies are needed to confirm our findings.

  3. Comparative study of decomposable and indecomposable biopsy needle in lung puncture biopsy

    International Nuclear Information System (INIS)

    Wang Bo; Sheng Zhanxin; Wen Yamin; Zhang Liping; Wen Zongqiu

    2007-01-01

    Objective: To contrast the clinical practice characteristics with decomposable and indecomposable biopsy needle in the CT-guided lung puncture biopsy. Methods: 50 patients with lung tumour carried on puncture biopsy under the CT guidance were divided in two groups randomly: Group A (25 examples): using the indecomposable BioPinceTM biopsy needle; Group B(25 examples): using the decomposable Precisa or Vitesse biopsy needle. The puncture biopsy organization quantity, the first time puncture success rate, the pathological diagnosis result and the incidence of puncture complication were compared in two groups. Results: More striped structures were gained obviously in group A than in group B: 24/25 and 11/25 respectively (P>0.05), The pathological diagnosis 'serious extrusion amoebocyte and nature undetermined' only occurred in group B. But the first time puncture success rate was lower in group A than in B: 52%(13/25) and 80%(20/25) respectively (P>0.05), The incidence of hemorrhage and pneumothorax in group A was higher slightly: 84% and 72%, 16% and 4% respectively (P>0.05). Conclusion: The indecomposable needle (BioPinceTM) was better in lung puncture biopsy, but the lower first time puncture success rate also increases the risk of operation and complication in some degree because of the structure of the needle. On the contrary, decomposable needle (the Precisa or the Vitesse) was not the best choice in lung puncture biopsy. But it had the original superiority, especially regarding the special patient such as patient with small tumour, thin thoracic wall, bad physique for its nimble operation. It is essential for us to use the two different types of biopsy needle rationally to enhance the level of CT-guided lung puncture biopsy. (authors)

  4. Transjugular liver biopsy : the efficacy of quick-core biopsy needle system

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Gyoo Sik; Ahn, Byung Kwon; Lee, Sang Ouk; Chang, Hee Kyong; Oh, Kyung Seung; Huh, Jin Do; Joh, Young Duk [Kosin Medical College, Pusan (Korea, Republic of)

    1998-02-01

    To evaluate the efficacy of the Quick-Core biopsy needle system in performing transjugular liver biopsy. Between December 1995 and June 1997, eight patients underwent transjugular liver biopsy involving use of the Quick-Core biopsy needle system; the conditions involved were coagulopathy (n=4), thrombocytopenia (n=3), and ascites (n=1). Via the right internal jugular vein, the right hepatic vein was selectively catheterized with a 7-F transjugular guiding catheter, and a14-guage stiffening cannula was then inserted through this catheter; to obtain core tissue, a Quick-Core needle was then advanced into the liver parenchyma through the catheter-cannula combination. Eighteen- and 19-guage needles were used in three and five patients, respectively; specimen size, adequacy of the biopsy specimen and histologic diagnosis were determined, and complications were recorded. Biopsy was successful in all patients. The mean length of the specimen was 1.4 cm (1.0 - 1.8 cm), and all were adequate for pathologic examinations ; specific diagnosis was determined in all patients. There were two malignant neoplasms, two cases of veno-occlusive disease, and one case each of cirrhosis, fulminant hepatitis, Banti syndrome and Budd-Chiari syndrome. One patient complained of neck pain after the procedure, but no serious procedural complications were noted. Our preliminary study shows that the Quick-Core biopsy needle system is safe and provides adequate core tissues with high diagnostic yields. (author). 23 refs., 1 tab., 3 figs.

  5. Transjugular liver biopsy : the efficacy of quick-core biopsy needle system

    International Nuclear Information System (INIS)

    Jung, Gyoo Sik; Ahn, Byung Kwon; Lee, Sang Ouk; Chang, Hee Kyong; Oh, Kyung Seung; Huh, Jin Do; Joh, Young Duk

    1998-01-01

    To evaluate the efficacy of the Quick-Core biopsy needle system in performing transjugular liver biopsy. Between December 1995 and June 1997, eight patients underwent transjugular liver biopsy involving use of the Quick-Core biopsy needle system; the conditions involved were coagulopathy (n=4), thrombocytopenia (n=3), and ascites (n=1). Via the right internal jugular vein, the right hepatic vein was selectively catheterized with a 7-F transjugular guiding catheter, and a14-guage stiffening cannula was then inserted through this catheter; to obtain core tissue, a Quick-Core needle was then advanced into the liver parenchyma through the catheter-cannula combination. Eighteen- and 19-guage needles were used in three and five patients, respectively; specimen size, adequacy of the biopsy specimen and histologic diagnosis were determined, and complications were recorded. Biopsy was successful in all patients. The mean length of the specimen was 1.4 cm (1.0 - 1.8 cm), and all were adequate for pathologic examinations ; specific diagnosis was determined in all patients. There were two malignant neoplasms, two cases of veno-occlusive disease, and one case each of cirrhosis, fulminant hepatitis, Banti syndrome and Budd-Chiari syndrome. One patient complained of neck pain after the procedure, but no serious procedural complications were noted. Our preliminary study shows that the Quick-Core biopsy needle system is safe and provides adequate core tissues with high diagnostic yields. (author). 23 refs., 1 tab., 3 figs

  6. Stereotoracic skin biopsy in non-palpable woman mammary glands lesions

    International Nuclear Information System (INIS)

    Leborgne, Francisco; Mezzera, Julieta

    1999-01-01

    Seventy stereotactic breast biopsies in non palpable lesions were performed in asintomatic patients, studied with mammography, physical examination and high-resolution ultrasonography. A 14-gauge cutting needle was used with excursion of 2 and 20 mm. in high likelihood probably benign lesions and low likelihood probably malignant lesions, not snographical evident and not less than 4 mm. in diameter. Long term follow-up or surgical correlation is available in only 46 biopsies, with 35 negative results and 11 positive results for cancer. Follow-up mammography was recommended in 34 of 35 negative results and one case showed mammographic lesion progression, a false negative result, with sensitivity 90.9% and NPV 97%. Needle wire localization and open surgery was recommended in 11 positive results, with total agreement between stereotactic core biopsy and open surgery, with specificity 100% and PPV 100%. The indication of stereotactic biopsy in non palpable lesions as an alternative to surgical biopsy in order to decrease the number of surgical biopsies with negative results and in consequence lowering costs of diagnosis of asintomatic malignant lesions, with error of 2.1% and 2.8% minor complications

  7. Life-threatening meningitis resulting from transrectal prostate biopsy

    Institute of Scientific and Technical Information of China (English)

    Zhou-Jun Shen; Shan-Wen Chen; Hua Wang; Xie-Lai Zhou; Ju-Ping Zhao

    2005-01-01

    After antibiotic prophylaxis with metronidazole and levofloxacin, a transrectal sextant biopsy was performed under the guide of transrectal ultrasonography (TRUS) for a 75-year-old suspicious patient with prostate adenocarcinoma.Although antibiotics were also given after this procedure, the patient still developed fever, anxious, agrypnia and headache. Blood cultures remained negative. Lumbar puncture was performed and was consistent with Escherichia coli bacterial meningitis.

  8. Development of a permanently controllable rotating biopsy device. Pt. I. Theoretical considerations and in-vitro results for five different prototypes

    International Nuclear Information System (INIS)

    Schaefer, Philipp Jost; Jahnke, T.; Andres, H.; Heller, M.; Schaefer, F.K.; Hedderich, J.

    2009-01-01

    Purpose: to develop different prototypes of permanently controllable rotating biopsy devices with determination of the most efficient prototype in biopsies in bovine myocardium. Materials and Methods: Five different prototypes of 18-gauge rotating biopsy devices were designed and constructed, four (1-4) with various drill-like cutting edges and one (5) cannula type with a lancet-like helically bent cutting edge. Using bovine myocardium as the biopsy tissue, n = 100 specimens per prototype were obtained, and a quantitative analysis including tissue fragmentation, length in mm and weight in mg was carried out. For statistical analysis, the chi-square test for tissue fragmentation and Kruskal-Wallis test for the parameters length and weight were calculated. Results: prototype 5 showed the highest rate of extraction of one-fragment specimens in n=66 cases and the lowest rate of failure to obtain tissue in n=11 cases. The mean length/weight were 4.15 mm/3.91 mg for prototype 1, 1.80 mm/1.66 mg for prototype 2, 4.61 mm/3.28 mg for prototype 3, 5.20 mm/3.74 mg for prototype 4, and 9.57 mm/6.97 mg for prototype 5. In all three categories, prototype 5 was significantly superior to the prototypes 1-4 with p < 0.001. Conclusion: the cannula type with a lancet-like helically bent cutting edge proved to be the most efficient prototype and may now be tested competitively against established automated biopsy devices in vitro. (orig.)

  9. Aortography following subdiaphragmal aortic biopsy

    International Nuclear Information System (INIS)

    Schimmler, J.

    1982-01-01

    A juxtaposition of the subdiaphragmal and infrarenal translumbar aortic biopsy sites showed decisive advantages in favour of the higher site: a more stable position because of better anatomic fixation and rarer incidence of vascular alterations, a wider vascular lumen. Disadvantages lie in the fact that the large visceral arteries (especially Tr. coeliacus) branch off nearly and in the close anatomic relationship to large abdominal organs and the thoracal region. Evaluation of the radiographical image of the vascular tree after subdiaphragmal aortic biopsy showed an average 82% of the vessels to the area of the Knees to be assessable (renal arteries approximately 93%, popliteal arteries approximately 70%). Beyong, the method proved unsatisfactory: 52% of the vessels could not, or not safety, be evaluated. A relatively broad spectrum of indications by comparison with transfemoral catheter aortography had no influence on the rate of complications with reference to either method. A comparison of the topographic conditions shows the need for even more scrupulons observation of the technique in subdiaphragmal biopsy than in the infrarenal one. To sum up the results obtained, subdiaphregmal translumbar aortography is to be preferred to the infrarenal one where transfemoral catheter aortography is contra-indicated, within the limits mentioned. (orig.) [de

  10. PROGNOSTIC FACTORS OF POSITIVE RESULTS OF MULTIFOCAL TRUS-GUIDED VESICOURETHRAL ANASTOMOSIS BIOPSY IN PATIENTS WITH BIOCHEMICAL RECURRENCE AFTER RADICAL PROSTATECTOMY

    Directory of Open Access Journals (Sweden)

    P. D. Demeshko

    2014-07-01

    Full Text Available Purpose. To evaluate influence of clinical, biochemical and histological factors to detection rate of local recurrence following radical prostatectomy (RPE using multifocal TRUS-guided vesicourethral anastomosis (VUA biopsy.Material and methods. 59 patients with newly diagnosed biochemical recurrence (BR after RPE were included into prospective study. All of them underwent multifocal TRUS-guided VUA biopsy. Сlinical variables (serum prostate-specifi c antigen [PSA] level and PSA kinetics, time RPE-BR, Gleason grade, stage after RPE and clinical findings were evaluated. Logistic regression and receiver operating characteristic (ROC curve analyses were performed.Results. The detection rate of local prostate recurrence with TRUS-guided VUA biopsy was 45,8 % (95 % CI 33,7–58,3. At multivariate analysis only PSA level at the moment of biopsy (≤ 1,5 ng/ml vs > 1,5 ng/ml and time RPE-BR (≤ 15 months vs > 15 months were significantly associated with positive results of multifocal TRUS-guided VUA biopsy (p < 0,05.Conclusion The detection rate of local prostate recurrence with TRUS-guided VUA biopsy depends on combination of independent predictors (PSA level at the moment of biopsy and time RPE—BR.

  11. Testicular biopsy in psittacine birds (Psittaciformes): impact of endoscopy and biopsy on health, testicular morphology, and sperm parameters.

    Science.gov (United States)

    Hänse, Maria; Krautwald-Junghanns, Maria-Elisabeth; Reitemeier, Susanne; Einspanier, Almuth; Schmidt, Volker

    2013-12-01

    Histologic examination of a testicular biopsy sample may be required to evaluate the reproductive status of male psittacine birds. The purpose of this study was to evaluate the viability of testicular sampling from live birds by assessing the impact on the birds' health, testicular integrity, and sperm quality. Testicular biopsy samples were obtained by endoscopy 4 times during 12 months from 9 cockatiels (Nymphicus hollandicus) and 7 rose-ringed parakeets (Psittacula krameri). Only 2 of 16 birds showed testicular cicatrization or divided testicular tissue after a single endoscopy. Further complications, such as damage to the air sacs or bleeding, predominantly occurred in subsequent endoscopies. In both species, endoscopy and testicular biopsy caused only minor or transient effects on sperm production and sperm quality. These results support that a single testicular biopsy is a viable method for evaluating the reproductive status of male psittacine birds.

  12. Barbed micro-spikes for micro-scale biopsy

    Science.gov (United States)

    Byun, Sangwon; Lim, Jung-Min; Paik, Seung-Joon; Lee, Ahra; Koo, Kyo-in; Park, Sunkil; Park, Jaehong; Choi, Byoung-Doo; Seo, Jong Mo; Kim, Kyung-ah; Chung, Hum; Song, Si Young; Jeon, Doyoung; Cho, Dongil

    2005-06-01

    Single-crystal silicon planar micro-spikes with protruding barbs are developed for micro-scale biopsy and the feasibility of using the micro-spike as a micro-scale biopsy tool is evaluated for the first time. The fabrication process utilizes a deep silicon etch to define the micro-spike outline, resulting in protruding barbs of various shapes. Shanks of the fabricated micro-spikes are 3 mm long, 100 µm thick and 250 µm wide. Barbs protruding from micro-spike shanks facilitate the biopsy procedure by tearing off and retaining samples from target tissues. Micro-spikes with barbs successfully extracted tissue samples from the small intestines of the anesthetized pig, whereas micro-spikes without barbs failed to obtain a biopsy sample. Parylene coating can be applied to improve the biocompatibility of the micro-spike without deteriorating the biopsy function of the micro-spike. In addition, to show that the biopsy with the micro-spike can be applied to tissue analysis, samples obtained by micro-spikes were examined using immunofluorescent staining. Nuclei and F-actin of cells which are extracted by the micro-spike from a transwell were clearly visualized by immunofluorescent staining.

  13. Usefulness of CT fluoroscopy-guided percutaneous needle biopsy in the presence of pneumothorax during biopsy

    International Nuclear Information System (INIS)

    O, Dong Hyun; Cho, Young Jun; Park, Yong Sung; Hwang, Cheol Mok; Kim, Keum Won; Kim, Ji Hyung

    2006-01-01

    When pneumothorax occurs during a percutaneous needle biopsy, the radiologist usually stops the biopsy. We evaluated the usefulness of computed tomographic (CT) fluoroscopy-guided percutaneous needle biopsy in the presence of pneumothorax during biopsy. We performed 288 CT fluoroscopy guided percutaneous needle biopsies to diagnose the pulmonary nodules. Twenty two of these patients had pneumothorax that occurred during the biopsy without obtaining an adequate specimen. After pneumothorax occurred, we performed immediate CT fluoroscopy guided percutaneous needle biopsies using an 18-gauge cutting needle. We evaluated the success rate of the biopsies and also whether or not the pneumothorax progressed. We classified these patients into two groups according to whether the pneumothorax progressed (Group 2) or not (Group 1) by measuring the longest distance between the parietal pleura and the visceral pleura both in the early and late pneumothorax. Additionally, we analyzed the relationship between the progression of pneumothorax after biopsy and 1) the depth of the pulmonary nodule; 2) the number of biopsies; 3) the presence or absence of emphysema at the biopsy site; and 4) the size of the pulmonary nodule. Biopsy was successful in 19 of 22 nodules (86.3%). Of the 19 nodules, 12 (63.2%) were malignant and 7 (36.8%) were benign. Twelve patients (54.5%) were classified as group 1 and 10 patients (45.4%) as group 2. The distance between the lung lesion and pleura showed a statistically significant difference between these two groups: ≤ 1 cm in distance for group 1 (81.8%) and group 2 (18.2%), and > 1 cm in distance for group 1 (30%) and group 2 (70%), ρ 0.05). When early pneumothorax occurs during a biopsy, CT fluoroscopy guided percutaneous needle biopsy is an effective and safe procedure. Aggravation of pneumothorax after biopsy is affected by the depth of the pulmonary nodule

  14. US-guided percutaneous biopsies with a biopsy gun

    International Nuclear Information System (INIS)

    Ahn, In Oak; Kim, Hyung Jin; Kim, Jae Hyung; Lee, Goo; Jung, Sung Hoon

    1993-01-01

    Core tissue for histologic study is believed by many pathologist to be more diagnostic than material from needle aspiration. Recently introduced automatched biopsy gun simplifies core biopsies with increased quantity and quality of samples. Authors performed 38 percutaneous biopsies from 38 patients with 18G automated biopsy guns under US guide. Diagnostic target tissues were obtained in 33 biopsies(87%), inadequate tissues in 4(11%), and adequate but not of target tissue in 1(3%). There was no major complication requiring treatment, but pain needing analgesics and pain with nausea/vomiting were experienced in 2 and 1 biopsies respectively. Average number of needle passes was 1.5. We concluded that US guided gun biopsy was a easy and safe way to obtain tissue samples of good quantity and quality, especially useful in hospitals without constant availability of specialist in cytopathology

  15. Malignant-looking thyroid nodules with size reduction: Core needle biopsy results

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ha Young; Baek, Jung Hwan; Ha, Eun Jun; Park, Jee Won; Lee, Jeong Hyun; Song, Dong Eun; Shong, Young Kee [Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of)

    2016-08-15

    The aim of this study was to evaluate whether malignant-looking thyroid nodules with size reduction were malignant or not. From November 2010 to July 2011, we retrospectively enrolled 16 patients with 16 nodules (11 females and five males; mean age, 55 years) who underwent core needle biopsy (CNB), and whose thyroid nodules had malignant ultrasonographic (US) features, although they showed size reduction (>20% decrease in maximum diameter) during the follow-up period (mean, 37±27 months). The histologic findings of the CNB specimen were reviewed and correlated with the US findings. US studies were analyzed for their internal content, shape, margin, echogenicity, the presence of microcalcification and macrocalcification, inner isoechoic rim, and low-echoic halo. All nodules were confirmed as benign by CNB. Pathologic analysis was available for 12 CNB specimens. US imaging showed central hypoechogenicity or marked hypoechogenicity in all cases and a peripheral isoechoic rim in 15 nodules. US-pathologic correlation showed that the central hypoechoic area was primarily composed of fibrosis (12/12) and hemorrhage (8/12) and that the isoechoic rim was composed of follicular cells. In our study, the CNB results of all of the malignant-looking thyroid nodules with size reduction were benign and were primarily composed of internal fibrosis and hemorrhage. Understanding these US and pathologic features could prevent repeated fine-needle aspiration or unnecessary diagnostic surgery.

  16. Image guided versus palpation guided core needle biopsy of palpable breast masses: a prospective study

    Directory of Open Access Journals (Sweden)

    Smriti Hari

    2016-01-01

    Interpretation & conclusions: Our results showed that in palpable breast masses, image guided biopsy was superior to palpation guided biopsy in terms of sensitivity, false negative rate and repeat biopsy rates.

  17. MR-guided transgluteal biopsies with an open low-field system in patients with clinically suspected prostate cancer: technique and preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Zangos, Stephan [Johann Wolfgang Goethe-University, Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt/Main (Germany); Johann Wolfgang Goethe-University, Institute for Diagnostic and Interventional Radiology, Frankfurt/Main (Germany); Eichler, Katrin; Engelmann, Kerstin; Ahmed, Mukhtiar; Dettmer, Sebastian; Herzog, Christopher; Pegios, Wasilios; Wetter, A.; Lehnert, Thomas; Mack, Martin G.; Vogl, Thomas J. [Johann Wolfgang Goethe-University, Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt/Main (Germany)

    2005-01-01

    The purpose of this study was to examine the feasibility and safety of MR-guided biopsies with a transgluteal approach in patients with uncertain or suspicious prostate lesions. Twenty-five patients with uncertain or suspicious focal prostate lesions detected by high-field MR imaging of the prostate gland using endorectal coil imaging were biopsied with a transgluteal approach in a low-field MRI system (0.2 T, Concerto, Siemens). The procedures were guided using T1-weighted FLASH sequences. The prostate gland was biopsied repeatedly with a coaxial technique through a 15-gauge pencil tip with a 16-gauge biopsy handy (median 3.8 samples per patient). Complications and biopsy findings were documented retrospectively. Using T1-weighted sequences biopsy procedures were performed successfully with MR guidance in all cases without any side effects or complications. The median intervention time was 11.3 min. Pathological findings revealed ten cases of hyperplasia or atrophy, three cases of prostatitis, ten cases of carcinoma and two cases of normal tissue. The clinical follow-up showed that in two patients prostate cancer was missed at MR-guided biopsy. Transgluteal MR-guided biopsy of the prostate gland is a safe and promising approach for histological clarification of uncertain or suspicious lesions. (orig.)

  18. Computed tomography guided needle biopsy: experience from 1,300 procedures

    Energy Technology Data Exchange (ETDEWEB)

    Chojniak, Rubens; Isberner, Rony Klaus; Viana, Luciana Marinho; Yu, Liao Shin; Aita, Alessandro Amorim; Soares, Fernando Augusto [Hospital do Cancer A.C. Camargo, Sao Paulo, SP (Brazil). Dept. de Radiologia e Patologia

    2006-01-15

    Context and objective: computed tomography (CT) guided biopsy is widely accepted as effective and safe for diagnosis in many settings. Accuracy depends on target organ and needle type. Cutting needles present advantages over fine needles. This study presents experience from CT guided biopsies performed at an oncology center. Design and setting: retrospective study at Hospital do Cancer A. C. Camargo, Sao Paulo.Methods: 1,300 consecutive CT guided biopsies performed between July 1994 and February 2000 were analyzed. Nodules or masses were suspected as primary malignancy in 845 cases (65%) or metastatic lesion in 455 (35%). 628 lesions were thoracic, 281 abdominal, 208 retroperitoneal, 134 musculoskeletal and 49 head/neck. All biopsies were performed by one radiologist or under his supervision: 765 (59%) with 22-gauge fine-needle/aspiration technique and 535 (41%) with automated 16 or 18-gauge cutting-needle biopsy. Results: adequate samples were obtained in 70-92% of fine-needle and 93-100% of cutting-needle biopsies. The specific diagnosis rates were 54-67% for fine-needle and 82-100% for cutting-needle biopsies, according to biopsy site. For any site, sample adequacy and specific diagnosis rate were always better for cutting-needle biopsy. Among 530 lung biopsies, there were 84 pneumothorax (16%) and two hemothorax (0.3%) cases, with thoracic drainage in 24 (4.9%). Among abdominal and retroperitoneal biopsies, there were two cases of major bleeding and one of peritonitis. Conclusion: both types of needle showed satisfactory results, but cutting-needle biopsy should be used when specific diagnosis is desired without greater incidence of complications. (author)

  19. Combined colonoscopy and endometrial biopsy cancer screening results in women with Lynch syndrome.

    Science.gov (United States)

    Nebgen, Denise R; Lu, Karen H; Rimes, Sue; Keeler, Elizabeth; Broaddus, Russell; Munsell, Mark F; Lynch, Patrick M

    2014-10-01

    Endometrial biopsy (EMBx) and colonoscopy performed under the same sedation is termed combined screening and has been shown to be feasible and to provide a less painful and more satisfactory experience for women with Lynch syndrome (LS). However, clinical results of these screening efforts have not been reported. The purpose of this study was to evaluate the long-term clinical outcomes and patient compliance with serial screenings over the last 10.5 years. We retrospectively analyzed the data for 55 women with LS who underwent combined screening every 1-2 years between 2002 and 2013. Colonoscopy and endometrial biopsy were performed by a gastroenterologist and a gynecologist, with the patient under conscious sedation. Out of 111 screening visits in these 55 patients, endometrial biopsies detected one simple hyperplasia, three complex hyperplasia, and one endometrioid adenocarcinoma (FIGO Stage 1A). Seventy-one colorectal polyps were removed in 29 patients, of which 29 were tubular adenomas. EMBx in our study detected endometrial cancer in 0.9% (1/111) of surveillance visits, and premalignant hyperplasia in 3.6% (4/111) of screening visits. No interval endometrial or colorectal cancers were detected. Combined screening under sedation is feasible and less painful than EMBx alone. Our endometrial pathology detection rates were comparable to yearly screening studies. Our results indicate that screening of asymptomatic LS women with EMBx every 1-2 years, rather than annually, is effective in the early detection of (pre)cancerous lesions, leading to their prompt definitive management, and potential reduction in endometrial cancer. Copyright © 2014 Elsevier Inc. All rights reserved.

  20. Relationship of endometrial thickness detected by transvaginal sonography with the results of endometrial biopsy & hysteroscopic directed biopsy in post menopausal bleeding

    Directory of Open Access Journals (Sweden)

    Vahid Dastjerdi M

    2008-05-01

    Full Text Available Background: Post-menopausal hemorrhage is one of the most common complains in gynecologic clinics. More than 60% of these cases have abnormal findings in diagnostic work ups. There is contraversy about the best diagnostic method for evaluating post-menopausal hemorrhage. The aim of this study was to evaluate the results of Trans-Vaginal Ultrasonography and compare its result to ones derived from direct endometrial biopsy and Hysteroscopy findings.Methods: In a cross-sectional study, menopausal women who attended the outpatient clinic of Arash Hospital, Tehran University of medical Sciences, from April 2005 to March 2006 with the complain of hemorrhage were evaluated. In all of these patients, after getting informed consent, Trans-Vaginal Ultrasonography, Dilatation and Curettage and Hysteroscopy were performed.Results: The total number of 90 women was recruited to the study with the age range of 41-80 years. The mean age of participants was 53.84 ± 6 years and 4.3 ± 5.1 years had passed from their menopause. The mean thickness of endometrium, measured by Trans Vaginal ultrasonography was 6.25 ± 3.7 millimeter. In the biopsy derived specimens, the most finding pathological presentation was atrophy (48.9% and the Proliferative endometrium had the second prevalence (36.7%. Atrophy (44.4% and Proliferative endometrium (33.3% were the most prevalent finding in Hysteroscopy. There was a significant difference in endometrial thickness between groups of different pathological findings. A significant difference in endometrial thickness was also seen between groups with different Hysteroscopic finding. By grouping the data according to endometrial thickness, it became evident that endometrial thickness can predict the outcome of endometrial biopsy and Hysteroscopic finding efficiently. We used ROC curves to find the best grouping threshold for endometrial thickness to achieve the best sensitivity and specificity.Conclusion: Measuring the endometrial

  1. Sonographically guided core biopsy of the breast: comparison of 14-gauge automated gun and 11-gauge directional vacuum-assisted biopsy methods

    International Nuclear Information System (INIS)

    Cho, Nariya; Moon, Woo Kyung; Cha, Joo Hee

    2005-01-01

    To compare the outcomes of 14-gauge automated biopsy and 11-gauge vacuum-assisted biopsy for the sonographically guided core biopsies of breast lesions. We retrospectively reviewed all sonographically guided core biopsies performed from January 2002 to February 2004. The sonographically guided core biopsies were performed with using a 14-gauge automated gun on 562 breast lesions or with using an 11-gauge vacuum-assisted device on 417 lesions. The histologic findings were compared with the surgical, imaging and follow-up findings. The histologic underestimation rate, the repeat biopsy rate and the false negative rates were compared between the two groups. A repeat biopsy was performed on 49 benign lesions because of the core biopsy results of the high-risk lesions (n=24), the imaging-histologic discordance (n=5), and the imaging findings showing disease progression (n=20). The total underestimation rates, according to the biopsy device, were 55% (12/22) for the 14-gauge automated gun biopsies and 36% (8/22) for the 11-gauge vacuum-assisted device (ρ = 0.226). The atypical ductal hyperplasia (ADH) underestimation (i.e., atypical ductal hyperplasia at core biopsy and carcinoma at surgery) was 58% (7/12) for the 14-gauge automated gun biopsies and 20% (1/5) for the 11-gauge vacuum-assisted biopsies. The ductal carcinoma in situ (DCIS) underestimation rate (i.e., ductal carcinoma in situ upon core biopsy and invasive carcinoma found at surgery) was 50% (5/10) for the 14-gauge automated gun biopsies and 41% (7/17) for the 11-gauge vacuum-assisted biopsies. The repeat biopsy rates were 6% (33/562) for the 14-gauge automated gun biopsies and 3.5% (16/417) for the 11-gauge vacuum-assisted biopsies. Only 5 (0.5%) of the 979 core biopsies were believed to have missed the malignant lesions. The false-negative rate was 3% (4 of 128 cancers) for the 14-gauge automated gun biopsies and 1% (1 of 69 cancers) for the 11-gauge vacuum-assisted biopsies. The outcomes of the

  2. Ultrasound-guided diagnostic breast biopsy methodology: retrospective comparison of the 8-gauge vacuum-assisted biopsy approach versus the spring-loaded 14-gauge core biopsy approach

    Science.gov (United States)

    2011-01-01

    Background Ultrasound-guided diagnostic breast biopsy technology represents the current standard of care for the evaluation of indeterminate and suspicious lesions seen on diagnostic breast ultrasound. Yet, there remains much debate as to which particular method of ultrasound-guided diagnostic breast biopsy provides the most accurate and optimal diagnostic information. The aim of the current study was to compare and contrast the 8-gauge vacuum-assisted biopsy approach and the spring-loaded 14-gauge core biopsy approach. Methods A retrospective analysis was done of all ultrasound-guided diagnostic breast biopsy procedures performed by either the 8-gauge vacuum-assisted biopsy approach or the spring-loaded 14-gauge core biopsy approach by a single surgeon from July 2001 through June 2009. Results Among 1443 ultrasound-guided diagnostic breast biopsy procedures performed, 724 (50.2%) were by the 8-gauge vacuum-assisted biopsy technique and 719 (49.8%) were by the spring-loaded 14-gauge core biopsy technique. The total number of false negative cases (i.e., benign findings instead of invasive breast carcinoma) was significantly greater (P = 0.008) in the spring-loaded 14-gauge core biopsy group (8/681, 1.2%) as compared to in the 8-gauge vacuum-assisted biopsy group (0/652, 0%), with an overall false negative rate of 2.1% (8/386) for the spring-loaded 14-gauge core biopsy group as compared to 0% (0/148) for the 8-gauge vacuum-assisted biopsy group. Significantly more (P guided diagnostic breast biopsy procedure. Significantly more (P guided diagnostic breast biopsy procedure. Conclusions In appropriately selected cases, the 8-gauge vacuum-assisted biopsy approach appears to be advantageous to the spring-loaded 14-gauge core biopsy approach for providing the most accurate and optimal diagnostic information. PMID:21835024

  3. Mammographic scar for stereotaxic biopsy

    International Nuclear Information System (INIS)

    Guzman Tattis; Hincapie U, Ana Lucia; Patino P, Jairo Hernando

    1997-01-01

    It is reported the case of 56 years old woman who underwent a stereotactic biopsy because of having a circumscribed breast nodule. The histologic diagnosis was benign. After six months, during the mammographic control, it was noticed that the nodule showed irregular contours, because of that a surgical biopsy was performed. The histopathology was reported as benign. it is considered then, that the mammographic changes observed in the mammographic control are due to scar phenomenon after stereotactic biopsy. This findings has not been reported previously

  4. Importance of Local Control in Early-Stage Prostate Cancer: Outcomes of Patients With Positive Post-Radiation Therapy Biopsy Results Treated in RTOG 9408

    International Nuclear Information System (INIS)

    Krauss, Daniel J.; Hu, Chen; Bahary, Jean-Paul; Souhami, Luis; Gore, Elizabeth M.; Chafe, Susan Maria Jacinta; Leibenhaut, Mark H.; Narayan, Samir; Torres-Roca, Javier; Michalski, Jeff; Zeitzer, Kenneth L.; Donavanik, Viroon; Sandler, Howard; McGowan, David G.; Jones, Christopher U.; Shipley, William U.

    2015-01-01

    Purpose: The purpose of this study was to assess the association between positive post-radiation therapy (RT) biopsy results and subsequent clinical outcomes in males with localized prostate cancer. Methods and Materials: Radiation Therapy Oncology Group study 94-08 analyzed 1979 males with prostate cancer, stage T1b-T2b and prostate-specific antigen concentrations of ≤20 ng/dL, to investigate whether 4 months of total androgen suppression (TAS) added to RT improved survival compared to RT alone. Patients randomized to receive TAS received flutamide with luteinizing hormone releasing hormone (LHRH) agonist. According to protocol, patients without evidence of clinical recurrence or initiation of additional endocrine therapy underwent repeat prostate biopsy 2 years after RT completion. Statistical analysis was performed to evaluate the impact of positive post-RT biopsy results on clinical outcomes. Results: A total of 831 patients underwent post-RT biopsy, 398 were treated with RT alone and 433 with RT plus TAS. Patients with positive post-RT biopsy results had higher rates of biochemical failure (hazard ratio [HR] = 1.7; 95% confidence interval [CI] = 1.3-2.1) and distant metastasis (HR = 2.4; 95% CI = 1.3-4.4) and inferior disease-specific survival (HR = 3.8; 95% CI = 1.9-7.5). Positive biopsy results remained predictive of such outcomes after correction for potential confounders such as Gleason score, tumor stage, and TAS administration. Prior TAS therapy did not prevent elevated risk of adverse outcome in the setting of post-RT positive biopsy results. Patients with Gleason score ≥7 with a positive biopsy result additionally had inferior overall survival compared to those with a negative biopsy result (HR = 1.56; 95% CI = 1.04-2.35). Conclusions: Positive post-RT biopsy is associated with increased rates of distant metastases and inferior disease-specific survival in patients treated with definitive RT and was associated with inferior overall

  5. Hypoxia marker labeling in tumor biopsies: quantification of labeling variation and criteria for biopsy sectioning

    International Nuclear Information System (INIS)

    Thrall, Donald E.; Rosner, Gary L.; Azuma, Chieko; McEntee, Margaret C.; Raleigh, James A.

    1997-01-01

    Background and purpose: The error associated with using biopsy-based methods for assessing parameters reflective of the tumor microenvironment depends on the variability in distribution of the parameter throughout the tumor and the biopsy sample. Some attention has been given to intratumoral distribution of parameters, but little attention has been given to their intrabiopsy distribution. We evaluated the intrabiopsy distribution of CCI-103F, a 2-nitroimidazole hypoxia marker. Materials and methods: The hypoxia marker CCI-103F was studied in dogs bearing spontaneous solid tumors. Two biopsies were taken from each of seven tumors, for a total of 14 biopsies. Biopsies were serially sectioned and four to six contiguous slides from each 100-150 μm of the biopsy were used to formulate the best estimate of CCI-103F labeled area throughout the biopsy sample. One, two or four slides were then randomly selected from each biopsy and the labeled area, based on this limited sample, was compared to the estimate obtained from counting all available slides. Random sampling of slides was repeated 1000 times for each biopsy sample. Results: CCI-103F labeling variance throughout the biopsy decreased as the estimated overall labeled area in the biopsy decreased. The error associated with estimating the overall labeled area in a biopsy from a randomly selected subset of slides decreased as the number of slides increased, and as the overall labeled area in the biopsy decreased. No minimally labeled biopsy was classified as unlabeled based on limited sampling. Conclusion: With regard to CCI-103F labeling, quantification of the labeled area in four randomly selected slides from a biopsy can provide, in most biopsies, an estimate of the labeled area in the biopsy within an absolute range of ±0.05

  6. Image-guided pleural biopsy: diagnostic yield and complications

    International Nuclear Information System (INIS)

    Benamore, R.E.; Scott, K.; Richards, C.J.; Entwisle, J.J.

    2006-01-01

    Background: Pleural biopsy and cytology are standard procedures for the investigation of pleural disease. Recent medical literature has suggested that image-guided pleural biopsy shows improved sensitivity for the diagnosis of pleural malignancy, when compared with the more commonly performed reverse bevel needle biopsy such as Abrams' needle. In our centre there has been an increasing trend towards performing image-guided pleural biopsies, and to our knowledge there is no large published series documenting the complication rate and diagnostic yield. Methods: The radiology and pathology databases were searched for all image-guided [computed tomography (CT) and ultrasound (US)] pleural biopsies from January 2001 to December 2004. All imaging and histology were reviewed, and final diagnostic information about patients was obtained from the respiratory multidisciplinary team database and patient notes. A record was made of complications following biopsy, presence of pleura in the biopsy, and adequacy of tissue for histological diagnosis. Results: A total of 82 patients underwent 85 image-guided pleural biopsies over a 4-year period. 80 cases were performed under CT and five under US guidance. The rate of new pneumothorax detected by chest radiography was 4.7%. No patient required a chest drain or blood transfusion to treat complications. In 10 (12%) cases, there was inadequate tissue to reach a confident histological diagnosis and in eight (9%) of these, no pleura was present. Assuming all suspicious and inadequate biopsies are treated as benign, which is the worst case scenario, image-guided pleural biopsy has a sensitivity and specificity of 76% and 100%, respectively, for the diagnosis of malignant disease. Conclusions: Image-guided pleural biopsy is a safe procedure with few associated complications and has a higher sensitivity than previously published series for reverse cutting needle biopsy in the diagnosis of malignant pleural disease

  7. Image-guided pleural biopsy: diagnostic yield and complications

    Energy Technology Data Exchange (ETDEWEB)

    Benamore, R.E. [Department of Radiology and Department of Histopathology, Glenfield Hospital, University Hospitals of Leicester NHS Trust, Leicester (United Kingdom)]. E-mail: rachelbenamore@doctors.org.uk; Scott, K. [Department of Radiology and Department of Histopathology, Glenfield Hospital, University Hospitals of Leicester NHS Trust, Leicester (United Kingdom); Richards, C.J. [Department of Radiology and Department of Histopathology, Glenfield Hospital, University Hospitals of Leicester NHS Trust, Leicester (United Kingdom); Entwisle, J.J. [Department of Radiology and Department of Histopathology, Glenfield Hospital, University Hospitals of Leicester NHS Trust, Leicester (United Kingdom)

    2006-08-15

    Background: Pleural biopsy and cytology are standard procedures for the investigation of pleural disease. Recent medical literature has suggested that image-guided pleural biopsy shows improved sensitivity for the diagnosis of pleural malignancy, when compared with the more commonly performed reverse bevel needle biopsy such as Abrams' needle. In our centre there has been an increasing trend towards performing image-guided pleural biopsies, and to our knowledge there is no large published series documenting the complication rate and diagnostic yield. Methods: The radiology and pathology databases were searched for all image-guided [computed tomography (CT) and ultrasound (US)] pleural biopsies from January 2001 to December 2004. All imaging and histology were reviewed, and final diagnostic information about patients was obtained from the respiratory multidisciplinary team database and patient notes. A record was made of complications following biopsy, presence of pleura in the biopsy, and adequacy of tissue for histological diagnosis. Results: A total of 82 patients underwent 85 image-guided pleural biopsies over a 4-year period. 80 cases were performed under CT and five under US guidance. The rate of new pneumothorax detected by chest radiography was 4.7%. No patient required a chest drain or blood transfusion to treat complications. In 10 (12%) cases, there was inadequate tissue to reach a confident histological diagnosis and in eight (9%) of these, no pleura was present. Assuming all suspicious and inadequate biopsies are treated as benign, which is the worst case scenario, image-guided pleural biopsy has a sensitivity and specificity of 76% and 100%, respectively, for the diagnosis of malignant disease. Conclusions: Image-guided pleural biopsy is a safe procedure with few associated complications and has a higher sensitivity than previously published series for reverse cutting needle biopsy in the diagnosis of malignant pleural disease.

  8. Percutaneous computed tomography-guided core needle biopsy of soft tissue tumors: results and correlation with surgical specimen analysis

    Energy Technology Data Exchange (ETDEWEB)

    Chojniak, Rubens; Grigio, Henrique Ramos; Bitencourt, Almir Galvao Vieira; Pinto, Paula Nicole Vieira; Tyng, Chiang J.; Cunha, Isabela Werneck da; Aguiar Junior, Samuel; Lopes, Ademar, E-mail: chojniak@uol.com.br [Hospital A.C. Camargo, Sao Paulo, SP (Brazil)

    2012-09-15

    Objective: To evaluate the efficacy of percutaneous computed tomography (CT)-guided core needle biopsy of soft tissue tumors in obtaining appropriate samples for histological analysis, and compare its diagnosis with the results of the surgical pathology as available. Materials and Methods: The authors reviewed medical records, imaging and histological reports of 262 patients with soft-tissue tumors submitted to CT-guided core needle biopsy in an oncologic reference center between 2003 and 2009. Results: Appropriate samples were obtained in 215 (82.1%) out of the 262 patients. The most prevalent tumors were sarcomas (38.6%), metastatic carcinomas (28.8%), benign mesenchymal tumors (20.5%) and lymphomas (9.3%). Histological grading was feasible in 92.8% of sarcoma patients, with the majority of them (77.9%) being classified as high grade tumors. Out of the total sample, 116 patients (44.3%) underwent surgical excision and diagnosis confirmation. Core biopsy demonstrated 94.6% accuracy in the identification of sarcomas, with 96.4% sensitivity and 89.5% specificity. A significant intermethod agreement about histological grading was observed between core biopsy and surgical resection (p < 0.001; kappa = 0.75). Conclusion: CT-guided core needle biopsy demonstrated a high diagnostic accuracy in the evaluation of soft tissue tumors as well as in the histological grading of sarcomas, allowing an appropriate therapeutic planning (author)

  9. Clinical utility of an epigenetic assay to detect occult prostate cancer in histopathologically negative biopsies: results of the MATLOC study.

    Science.gov (United States)

    Stewart, Grant D; Van Neste, Leander; Delvenne, Philippe; Delrée, Paul; Delga, Agnès; McNeill, S Alan; O'Donnell, Marie; Clark, James; Van Criekinge, Wim; Bigley, Joseph; Harrison, David J

    2013-03-01

    Concern about possible false-negative prostate biopsy histopathology findings often leads to rebiopsy. A quantitative methylation specific polymerase chain reaction assay panel, including GSTP1, APC and RASSF1, could increase the sensitivity of detecting cancer over that of pathological review alone, leading to a high negative predictive value and a decrease in unnecessary repeat biopsies. The MATLOC study blindly tested archived prostate biopsy needle core tissue samples of 498 subjects from the United Kingdom and Belgium with histopathologically negative prostate biopsies, followed by positive (cases) or negative (controls) repeat biopsy within 30 months. Clinical performance of the epigenetic marker panel, emphasizing negative predictive value, was assessed and cross-validated. Multivariate logistic regression was used to evaluate all risk factors. The epigenetic assay performed on the first negative biopsies of this retrospective review cohort resulted in a negative predictive value of 90% (95% CI 87-93). In a multivariate model correcting for patient age, prostate specific antigen, digital rectal examination and first biopsy histopathological characteristics the epigenetic assay was a significant independent predictor of patient outcome (OR 3.17, 95% CI 1.81-5.53). A multiplex quantitative methylation specific polymerase chain reaction assay determining the methylation status of GSTP1, APC and RASSF1 was strongly associated with repeat biopsy outcome up to 30 months after initial negative biopsy in men with suspicion of prostate cancer. Adding this epigenetic assay could improve the prostate cancer diagnostic process and decrease unnecessary repeat biopsies. Copyright © 2013 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  10. Transcriptomics and proteomics show that selenium affects inflammation, cytoskeleton, and cancer pathways in human rectal biopsies.

    Science.gov (United States)

    Méplan, Catherine; Johnson, Ian T; Polley, Abigael C J; Cockell, Simon; Bradburn, David M; Commane, Daniel M; Arasaradnam, Ramesh P; Mulholland, Francis; Zupanic, Anze; Mathers, John C; Hesketh, John

    2016-08-01

    Epidemiologic studies highlight the potential role of dietary selenium (Se) in colorectal cancer prevention. Our goal was to elucidate whether expression of factors crucial for colorectal homoeostasis is affected by physiologic differences in Se status. Using transcriptomics and proteomics followed by pathway analysis, we identified pathways affected by Se status in rectal biopsies from 22 healthy adults, including 11 controls with optimal status (mean plasma Se = 1.43 μM) and 11 subjects with suboptimal status (mean plasma Se = 0.86 μM). We observed that 254 genes and 26 proteins implicated in cancer (80%), immune function and inflammatory response (40%), cell growth and proliferation (70%), cellular movement, and cell death (50%) were differentially expressed between the 2 groups. Expression of 69 genes, including selenoproteins W1 and K, which are genes involved in cytoskeleton remodelling and transcription factor NFκB signaling, correlated significantly with Se status. Integrating proteomics and transcriptomics datasets revealed reduced inflammatory and immune responses and cytoskeleton remodelling in the suboptimal Se status group. This is the first study combining omics technologies to describe the impact of differences in Se status on colorectal expression patterns, revealing that suboptimal Se status could alter inflammatory signaling and cytoskeleton in human rectal mucosa and so influence cancer risk.-Méplan, C., Johnson, I. T., Polley, A. C. J., Cockell, S., Bradburn, D. M., Commane, D. M., Arasaradnam, R. P., Mulholland, F., Zupanic, A., Mathers, J. C., Hesketh, J. Transcriptomics and proteomics show that selenium affects inflammation, cytoskeleton, and cancer pathways in human rectal biopsies. © The Author(s).

  11. Diffuse reflectance imaging: a tool for guided biopsy

    Science.gov (United States)

    Jayanthi, Jayaraj L.; Subhash, Narayanan; Manju, Stephen; Nisha, Unni G.; Beena, Valappil T.

    2012-01-01

    Accurate diagnosis of premalignant or malignant oral lesions depends on the quality of the biopsy, adequate clinical information and correct interpretation of the biopsy results. The major clinical challenge is to precisely locate the biopsy site in a clinically suspicious lesion. Dips due to oxygenated hemoglobin absorption have been noticed at 545 and 575 nm in the diffusely reflected white light spectra of oral mucosa and the intensity ratio R545/R575 has been found suited for early detection of oral pre-cancers. A multi-spectral diffuse reflectance (DR) imaging system has been developed consisting of an electron multiplying charge coupled device (EMCCD) camera and a liquid crystal tunable filter for guiding the clinician to an optimal biopsy site. Towards this DR images were recorded from 27 patients with potentially malignant lesions on their tongue (dorsal, lateral and ventral sides) and from 44 healthy controls at 545 and 575 nm with the DR imaging system. False colored ratio image R545/R575 of the lesion provides a visual discerning capability that helps in locating the most malignant site for biopsy. Histopathological report of guided biopsy showed that out of the 27 patients 16 were cancers, 9 pre-cancers and 2 lichen planus. In this clinical trial DR imaging has correctly guided 25 biopsy sites, yielding a sensitivity of 93% and a specificity of 98%, thereby establishing the potential of DR imaging as a tool for guided biopsy.

  12. Cold knife cone biopsy

    Science.gov (United States)

    ... biopsy; Pap smear - cone biopsy; HPV - cone biopsy; Human papilloma virus - cone biopsy; Cervix - cone biopsy; Colposcopy - cone biopsy Images Female reproductive anatomy Cold cone biopsy Cold cone removal References Baggish ...

  13. Ultrasound-guided renal biopsy: experience using an automated core biopsy system.

    Science.gov (United States)

    Chan, R; Common, A A; Marcuzzi, D

    2000-04-01

    To assess the safety and efficacy of ultrasound-guided percutaneous renal biopsy using an automated core biopsy system, and to determine radiologists' accuracy in predicting sample adequacy. Ninety-five biopsies were performed on 25 native kidneys and 70 renal allografts using a 16-gauge automated, spring-loaded core biopsy device under real-time sonographic guidance. Radiologists performing the biopsy estimated the number of core samples needed to obtain an adequate specimen, based on visual inspection of each core. The final determination of the number of samples was made by a pathology technologist who attended each biopsy, based on preliminary microscopic examination of tissue cores. After each biopsy, an ultrasonographic examination was performed to search for biopsy-related hemorrhage, and a questionnaire was given to the patient to determine biopsy-related complications, which were categorized as either minor or major. The main indication for biopsy was acute renal failure (in 43.2% of biopsies). An average of 3 tissue cores per biopsy were obtained. Of the 94 patients in whom a biopsy was conducted to exclude diffuse renal disease, a mean of 12.5 glomeruli were present in each specimen. Overall, adequate tissue for diagnosis was obtained in 98.9% of cases. The radiologists' estimate of the number of core samples needed concurred with the pathology technologists' determination of sample adequacy in 88.4% of cases. A total of 26 complications occurred (in 27.4% of biopsies), consisting of 23 minor (24.2%) and 3 major (3.2%) complications. Real-time sonographic guidance in conjunction with an automated core biopsy system is a safe and accurate method of performing percutaneous renal biopsy. Routine use of sonographic examinations to search for biopsy-related complications is not indicated. Radiologists are accurate in estimating sample adequacy in most cases; however, the presence of a pathology technologist at the biopsy procedure virtually eliminates the

  14. Liver biopsy

    Science.gov (United States)

    Biopsy - liver; Percutaneous biopsy ... the biopsy needle to be inserted into the liver. This is often done by using ultrasound. The ... the chance of damage to the lung or liver. The needle is removed quickly. Pressure will be ...

  15. The diagnostic ability of an additional midline peripheral zone biopsy in transrectal ultrasonography-guided 12-core prostate biopsy to detect midline prostate cancer

    Directory of Open Access Journals (Sweden)

    Inpyeong Hwang

    2016-01-01

    Full Text Available Purpose: The goal of this study was to evaluate the diagnostic effect of adding a midline peripheral zone (PZ biopsy to the 12-core biopsy protocol used to diagnose prostate cancer (PC, and to assess the clinical and pathologic characteristics of midline-positive PC in order to identify a potential subgroup of patients who would require midline PZ biopsy. Methods: This study included 741 consecutive patients who underwent a transrectal ultrasonography-guided, 12-core prostate biopsy with an additional midline core biopsy between October 2012 and December 2013. We grouped patients by the presence or absence of PC and subdivided patients with PC based on the involvement of the midline core. The clinical characteristics of these groups were compared, including serum prostate-specific antigen (PSA concentrations, PSA density, and pathological features in the biopsy specimens. Results: PC was detected in 289 patients (39.0%. Among the PC patients, 66 patients (22.8% had midline PC. No patients were diagnosed with PC based only on a midline core. The Gleason scores, number of positive cores, tumor core length, serum PSA concentrations, and PSA density were significantly higher in patients with midline-positive PC (P<0.001. Furthermore, significant cancer was more frequent in the midline-positive group (98.5% vs. 78.0%. Conclusion: Patients showing a positive result for PC in a midline PZ biopsy were more likely to have multiple tumors or large-volume PC with a high tumor burden. However, our data indicated that an additional midline core biopsy is unlikely to be helpful in detecting occult midline PC.

  16. Results of vardenafil mediated power Doppler ultrasound, contrast enhanced ultrasound and systematic random biopsies to detect prostate cancer.

    Science.gov (United States)

    Morelli, Girolamo; Pagni, Riccardo; Mariani, Chiara; Minervini, Riccardo; Morelli, Andrea; Gori, Francesco; Ferdeghini, Ezio Maria; Paterni, Marco; Mauro, Eva; Guidi, Elisa; Armillotta, Nicola; Canale, Domenico; Vitti, Paolo; Caramella, Davide; Minervini, Andrea

    2011-06-01

    We evaluated the ability of the phosphodiesterase-5 inhibitor vardenafil to increase prostate microcirculation during power Doppler ultrasound. We also evaluated the results of contrast and vardenafil enhanced targeted biopsies compared to those of standard 12-core random biopsies to detect cancer. Between May 2008 and January 2010, 150 consecutive patients with prostate specific antigen more than 4 ng/ml at first diagnosis with negative digital rectal examination and transrectal ultrasound, and no clinical history of prostatitis underwent contrast enhanced power Doppler ultrasound (bolus injection of 2.4 ml SonoVue® contrast agent), followed by vardenafil enhanced power Doppler ultrasound (1 hour after oral administration of vardenafil 20 mg). All patients underwent standard 12-core transrectal ultrasound guided random prostate biopsy plus 1 further sampling from each suspected hypervascular lesion detected by contrast and vardenafil enhanced power Doppler ultrasound. Prostate cancer was detected in 44 patients (29.3%). Contrast and vardenafil enhanced power Doppler ultrasound detected suspicious, contrast enhanced and vardenafil enhanced areas in 112 (74.6%) and 110 patients (73.3%), and was diagnostic for cancer in 32 (28.5%) and 42 (38%), respectively. Analysis of standard technique, and contrast and vardenafil enhanced power Doppler ultrasound findings by biopsy core showed significantly higher detection using vardenafil vs contrast enhanced power Doppler ultrasound and standard technique (41.2% vs 22.7% and 8.1%, p power Doppler ultrasound was 10% and 11.7% (p not significant). Vardenafil enhanced power Doppler ultrasound enables excellent visualization of the microvasculature associated with cancer and can improve the detection rate compared to contrast enhanced power Doppler ultrasound and the random technique. Copyright © 2011 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  17. Imaging-guided percutaneous needle biopsy for infectious spondylitis: Factors affecting culture positivity

    Energy Technology Data Exchange (ETDEWEB)

    Sung, Si Yoon; Kwon, Jong Won [Dept. of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2015-11-15

    To evaluate the variable factors affecting the results of percutaneous needle biopsies for infectious spondylitis. In all, 249 patients who underwent both MRI and percutaneous needle biopsies due to a suspicion of infectious spondylitis were evaluated with respect to the following factors: the usage of antibiotics before the procedure, the location of the biopsy, the guiding equipment used, the experience level of the operators, and the number of biopsies performed. The positivity of culture in cases of treated with antibiotics (16.3%) before the biopsy was lower than in the untreated cases (30.5%) (p = 0.004). Biopsies performed at the abscess (43.5%) and with fluoroscopic guidance (27.8%) showed higher culture positivity as well. The experience level of the operators and the number of biopsies had no effect on culture positivity. The usage of antibiotics before the biopsy, the biopsy's location, and the guiding equipment used affect the culture positivity, while the experience levels of the operators and the number of biopsies do not have an effect.

  18. Imaging-guided percutaneous needle biopsy for infectious spondylitis: Factors affecting culture positivity

    International Nuclear Information System (INIS)

    Sung, Si Yoon; Kwon, Jong Won

    2015-01-01

    To evaluate the variable factors affecting the results of percutaneous needle biopsies for infectious spondylitis. In all, 249 patients who underwent both MRI and percutaneous needle biopsies due to a suspicion of infectious spondylitis were evaluated with respect to the following factors: the usage of antibiotics before the procedure, the location of the biopsy, the guiding equipment used, the experience level of the operators, and the number of biopsies performed. The positivity of culture in cases of treated with antibiotics (16.3%) before the biopsy was lower than in the untreated cases (30.5%) (p = 0.004). Biopsies performed at the abscess (43.5%) and with fluoroscopic guidance (27.8%) showed higher culture positivity as well. The experience level of the operators and the number of biopsies had no effect on culture positivity. The usage of antibiotics before the biopsy, the biopsy's location, and the guiding equipment used affect the culture positivity, while the experience levels of the operators and the number of biopsies do not have an effect

  19. Complications of percutaneous renal tumor biopsy: An analysis of 340 consecutive biopsies

    DEFF Research Database (Denmark)

    René Rasmussen, Lars; Loft, Martina; Høyer, Søren

    Purpose Ultrasound Guided Percutaneous Kidney Biopsy (UGPKB) plays a major role in diagnosis of renal tumours. There seems to be little consensus regarding post-biopsy observation period. We aim to identify complications in UGPKB among outpatients with a suspected malignant renal lesion as well...... as the timing of onset of these complications, helping to clarify the optimal observation period. Many studies in this field suggest a lower complication risk for outpatients compared to hospitalized patients. In the latter group, an observation period of 24h after biopsy is often recommended. Material...... discrepancy. Results As for one third of the patients, analysed up until now, we find a total of one major complication and a few minor, all arisen within less than 6 hours after biopsy. Conclusions Rates of both major and minor complications in UGPKB are very low suggesting a shorter observation period...

  20. Oropharynx lesion biopsy

    Science.gov (United States)

    ... as papilloma) Fungal infections (such as candida) Histoplasmosis Oral lichen planus Precancerous sore (leukoplakia) Viral infections (such as Herpes simplex) Risks Risks of the procedure may ... Throat lesion biopsy; Biopsy - mouth or throat; Mouth lesion biopsy; Oral cancer - biopsy ...

  1. Grading of shoulder ulcerations in sows by biopsies

    DEFF Research Database (Denmark)

    Jensen, Henrik Elvang; Dahl-Pedersen, Kirstin; Barington, Krisitane

    2014-01-01

    legislation, stating that sows with shoulder ulcers grade 3 or 4 must be kept loose and have access to soft bedding. Thus, the aim of the present study was to evaluate if biopsies from the center of a shoulder ulcer can be used to point out animals for which an intervention must be initiated. Postmortem......, a punch biopsy was sampled from the center of the ulceration or from the tissue overlaying the tuber spina scapula. Afterward, the shoulders were cross-sectioned and evaluated grossly and histologically (“gold standard”). In total, 121 shoulders were included in the study, and the diagnostic value...... of a punch biopsy in grading shoulder ulcerations was evaluated. The results showed a sensitivity of 0.78, a specificity of 0.98, a positive likelihood ratio of 38.36, and a negative likelihood ratio of 0.22. The agreement between the cross-section evaluation and the punch biopsy was found to be 0...

  2. Ultrasound-guided core needle biopsy for breast cancer

    International Nuclear Information System (INIS)

    Naqvi, S.Q.H.; Solangi, R.A.; Memon, M.; Solangi, R.A.

    2008-01-01

    To evaluate the efficacy of ultrasound-guided core needle biopsy (US-CNB) as a preoperative diagnostic modality for breast cancer. Females with solid and/or intermediate breast lesions visualized on ultrasonography. Apart from clinical work-up, all the above mentioned patients underwent ultrasound-guided core needle biopsy and excisional biopsy of their breast lesions. The histopathological diagnosis on ultrasound-guided core needle biopsy was then compared with the findings of the excisional biopsy. Out of the total 93 cases, 47(50.5%) had benign lesions on ultrasound; US-CNB showed 24 as fibroadenomata, four with chronic non-specific mastitis, five chronic suppurative mastitis, one tuberculosis, four fat necrosis, two lactational adenoma and seven cases with benign ductal hyperplasia without atypia. Nine (9.7%) cases showed suspicious abnormality on ultrasound; US-CNB revealed five cases with atypical ductal hyperplasia, one ductal carcinoma in situ and three invasive ductal carcinoma. Thirty seven (39.8%) cases were highly suggestive of malignancy on ultrasound; US-CNB showed 34 as invasive ductal carcinoma, two invasive lobular and one medullary carcinoma. Excisional biopsy confirmed the diagnosis of ultrasound-guided core needle biopsy in all cases except four; one case of chronic suppurative mastitis was diagnosed as that of tuberculosis and three cases of atypial ductal hyperplasia as invasive ductal carcinoma. Hence there was no false positive case, but four (4.3%) false negative cases. The sensitivity of the US-CNB was thus 100% and specificity 91.1%. Ultrasound guided core needle biopsy is a satisfactory procedure for the histopathological diagnosis of breast lesions. Any unsatisfactory, suspicious or atypical change on US-CNB should be followed by an open biopsy. (author)

  3. Usefulness of ultrasound-guided mammotome biopsy for microcalcification

    Energy Technology Data Exchange (ETDEWEB)

    Kim, You Me [Dankook University Hospital, Seoul (Korea, Republic of); Park, Hee Boong [Park Breast Clinic, Seoul (Korea, Republic of); Ryu, Jin Woo [Cheonan Choongmu Hospital, Cheonan (Korea, Republic of)

    2005-08-15

    To evaluate the usefulness of ultrasound-guided mammotome biopsy for microcalcification and to suggest a new approach for the localization of microcalcifications which are not detected on ultrasound. Twenty-one calcific lesions in 21 women (aged 33-56 years) underwent ultrasound-guided, vacuum-assisted, mammotome biopsy and a mean of 14 specimens per lesion were obtained. Calcification retrieval was defined as identification of calcifications on specimen radiographs. In the 13 cases of calcifications which were not detected on ultrasound imaging, mammotome biopsy was performed after localization of one or two needles at the microcalcifications under mammography-guidance. Radiographs of the specimens and histologic findings were reviewed and scheduled follow-up imaging was performed for evaluation of the complications of biopsy. Ultrasound-guided, vacuum-assisted, mammotome biopsy removed all calcifications in 21 lesions. Eight (38%) lesions showed visible calcification on the ultrasound while 13 (62%) lesions were invisible, which underwent mammotome biopsy after needle localization under mammography-guidance. Surgery revealed DCIS in 1 (4.8%) of 21 lesions, infiltrating ductal carcinoma in two (9.5%), fibroadenomas with calcifications in 6 (28.6%), fibroadenmas with adenosis in 2(9.5%), and fibrocystic change with calcifications in 10 (47.6%). Clinical significant complications did not occur on follow-up examination in any of the cases. Ultrasound-guided, vacuum-assisted, mammotome biopsy was an effective method for microcalcifications on mammogram. The results suggested that mammotome biopsy after mammogram-guided, needle localization is a good alternative method for the diagnosis of microcalcifications which are undetectable in the ultrasound images.

  4. Usefulness of ultrasound-guided mammotome biopsy for microcalcification

    International Nuclear Information System (INIS)

    Kim, You Me; Park, Hee Boong; Ryu, Jin Woo

    2005-01-01

    To evaluate the usefulness of ultrasound-guided mammotome biopsy for microcalcification and to suggest a new approach for the localization of microcalcifications which are not detected on ultrasound. Twenty-one calcific lesions in 21 women (aged 33-56 years) underwent ultrasound-guided, vacuum-assisted, mammotome biopsy and a mean of 14 specimens per lesion were obtained. Calcification retrieval was defined as identification of calcifications on specimen radiographs. In the 13 cases of calcifications which were not detected on ultrasound imaging, mammotome biopsy was performed after localization of one or two needles at the microcalcifications under mammography-guidance. Radiographs of the specimens and histologic findings were reviewed and scheduled follow-up imaging was performed for evaluation of the complications of biopsy. Ultrasound-guided, vacuum-assisted, mammotome biopsy removed all calcifications in 21 lesions. Eight (38%) lesions showed visible calcification on the ultrasound while 13 (62%) lesions were invisible, which underwent mammotome biopsy after needle localization under mammography-guidance. Surgery revealed DCIS in 1 (4.8%) of 21 lesions, infiltrating ductal carcinoma in two (9.5%), fibroadenomas with calcifications in 6 (28.6%), fibroadenmas with adenosis in 2(9.5%), and fibrocystic change with calcifications in 10 (47.6%). Clinical significant complications did not occur on follow-up examination in any of the cases. Ultrasound-guided, vacuum-assisted, mammotome biopsy was an effective method for microcalcifications on mammogram. The results suggested that mammotome biopsy after mammogram-guided, needle localization is a good alternative method for the diagnosis of microcalcifications which are undetectable in the ultrasound images

  5. Antibiotic prophylaxis and complications following prostate biopsies - a systematic review

    DEFF Research Database (Denmark)

    Klemann, Nina; Helgstrand, John Thomas; Brasso, Klaus

    2017-01-01

    of the first dose of antibiotic, one study found that administration 24 h before biopsy versus administration immediately before reduced the relative risk of post-biopsy infection by 55%. Seven studies compared different durations of antibiotic prophylaxis. None showed any benefit from continuing prophylaxis......INTRODUCTION: Transrectal ultrasound-guided biopsies (TRUS-gb) are associated with both mild and serious complications. Prophylactic antibiotics reduce the risk of septicaemia and mortality; however, no international consensus exists on the timing and duration of antibiotics, including the optimal...... drug strategy. We reviewed the current evidence supporting use of prophylactic antibiotics and the risk of complications following prostate biopsies. METHODS: This review was drafted in accordance with the Prisma Guidelines. The PubMed, Embase and Cochrane databases were searched. RESULTS: A total...

  6. Pulmonary Masses: Initial Results of Cone-beam CT Guidance with Needle Planning Software for Percutaneous Lung Biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Braak, Sicco J., E-mail: sjbraak@gmail.com [St. Antonius Hospital, Department of Radiology (Netherlands); Herder, Gerarda J. M., E-mail: j.herder@antoniusziekenhuis.nl [St. Antonius Hospital, Department of Pulmonology (Netherlands); Heesewijk, Johannes P. M. van, E-mail: j.heesewijk@antoniusziekenhuis.nl; Strijen, Marco J. L. van, E-mail: m.van.strijen@antoniusziekenhuis.nl [St. Antonius Hospital, Department of Radiology (Netherlands)

    2012-12-15

    Purpose: To evaluate the outcome of percutaneous lung biopsy (PLB) findings using cone-beam computed tomographic (CT) guidance (CBCT guidance) and compared to conventional biopsy guidance techniques. Methods: CBCT guidance is a stereotactic technique for needle interventions, combining 3D soft-tissue cone-beam CT, needle planning software, and real-time fluoroscopy. Between March 2007 and August 2010, we performed 84 Tru-Cut PLBs, where bronchoscopy did not provide histopathologic diagnosis. Mean patient age was 64.6 (range 24-85) years; 57 patients were men, and 25 were women. Records were prospectively collected for calculating sensitivity, specificity, positive predictive value, negative predictive value, and accuracy. We also registered fluoroscopy time, room time, interventional time, dose-area product (DAP), and complications. Procedures were divided into subgroups (e.g., location, size, operator). Results: Mean lesion diameter was 32.5 (range 3.0-93.0) mm, and the mean number of samples per biopsy procedure was 3.2 (range 1-7). Mean fluoroscopy time was 161 (range 104-551) s, room time was 34 (range 15-79) min, mean DAP value was 25.9 (range 3.9-80.5) Gy{center_dot}cm{sup -2}, and interventional time was 18 (range 5-65) min. Of 84 lesions, 70 were malignant (83.3%) and 14 were benign (16.7%). Seven (8.3%) of the biopsy samples were nondiagnostic. All nondiagnostic biopsied lesions proved to be malignant during surgical resection. The outcome for sensitivity, specificity, positive predictive value, negative predictive value, and accuracy was 90% (95% confidence interval [CI] 86-96), 100% (95% CI 82-100), 100% (95% CI 96-100), 66.7% (95% CI 55-83), and 91.7% (95% CI 86-96), respectively. Sixteen patients (19%) had minor and 2 (2.4%) had major complications. Conclusion: CBCT guidance is an effective method for PLB, with results comparable to CT/CT fluoroscopy guidance.

  7. MR-guided biopsies

    International Nuclear Information System (INIS)

    Gehl, H.B.; Frahm, C.

    1998-01-01

    Biopsies were the first 'intervention' under MR guidance. After initial difficulties concerning ferromagnetic biopsy instruments and the design of MR scanners, the latest technological improvements rendered MR guidance for biopsies more feasible. In this article we illustrate present-day clinical experience in the field of abdominal, breast and bone biopsy. Important aspects regarding the different designs of 'interventional' MR scanners and the visualization of instruments for biopsy are discussed. (orig.) [de

  8. Nonalbumin proteinuria predominates in biopsy-proven tenofovir nephrotoxicity.

    Science.gov (United States)

    Sise, Meghan E; Hirsch, Jamie S; Canetta, Pietro A; Herlitz, Leal; Mohan, Sumit

    2015-05-15

    Tenofovir disoproxil fumarate (TDF) nephrotoxicity is characterized by proximal renal tubular injury and dysmorphic mitochondria resulting in proteinuria, orthoglycemic glycosuria, and other markers of proximal tubular dysfunction. The objective of this study was to determine the pattern of proteinuria in patients with biopsy-proven TDF nephrotoxicity. Retrospective chart review. Patients with biopsy-proven TDF nephrotoxicity were identified and their medical charts and biopsy reports were reviewed. Comparison was made with HIV-infected patients not on TDF who underwent kidney biopsy. We identified 43 biopsy-proven cases of TDF nephrotoxicity; mean age 54.7 ± 0.4 years, 53% men, 42% whites. Thirty-seven cases reported proteinuria by dipstick of which only 60% had at least 2+ proteinuria. Twenty-seven patients had urine protein quantified by either 24-h collection or spot urine protein-to-creatinine ratio; median proteinuria was 1742 mg/day [interquartile range (IQR) 1200-2000 mg] and 1667 mg/g creatinine (IQR 851-1967 mg/g), respectively. Ten patients had concurrent urinary albumin measured, with a median 236 mg/g creatinine (IQR 137-343 mg/g). The mean urine albumin-to-urine protein ratio (uAPR) was 0.17 (IQR 0.14-0.19), confirming that TDF nephrotoxicity is primarily associated with nonalbumin proteinuria. Control cases had a uAPR of 0.65 (IQR 0.55-0.79) P < 0.001. Histopathology showed the predominance of proximal tubular injury with characteristic mitochondrial abnormalities. In the largest published cohort of patients with biopsy-proven TDF nephrotoxicity, we show that low uAPR is a reliable feature of this disease. Because of the predominance of nonalbumin proteinuria, dipstick urinalysis may be unreliable in TDF nephrotoxicity.

  9. Prostatic biopsy after irradiation therapy for prostatic cancer

    International Nuclear Information System (INIS)

    Scardino, P.T.; Wheeler, T.M.

    1985-01-01

    To determine the prognostic significance of a routine needle biopsy of the prostate performed six to thirty-six months after the completion of definitive radiotherapy, biopsy results were analyzed in 146 patients who had no evidence of disease at the time of biopsy and who received no other therapy before proved recurrence of the tumor. Patients were followed up a mean of 3.9 years after radioactive gold seed implantation and external beam irradiation. The total dose was 8,000 rad. Among 146 patients, 56 (38%) had one or more positive biopsy results within this time interval. The positive biopsy rate correlated with the clinical stage ranging from 17 per cent in Stage B1N to 59 per cent in Stage C1. The risk of developing local recurrence or distant metastases at any given time after irradiation therapy was markedly greater in those patients with a positive biopsy result (p less than 0.0005). Prostatic biopsy is an accurate means of measuring the success of radiotherapy. A positive postirradiation biopsy result carries grave prognostic implications for the patient and indicates that the treatment has failed

  10. Computed-Tomography-Guided Percutaneous Core Needle Biopsies of Suspected Malignant Lymphomas: Impact of Biopsy, Lesion, and Patient Parameters on Diagnostic Yield

    International Nuclear Information System (INIS)

    Hesselmann, V.; Zaehringer, M.; Krug, B.; Wesselmann, C.; Haferkamp, K.; Wickenhauser, C.; Lackner, K.

    2004-01-01

    Purpose: To investigate the diagnostic yield of core needle biopsy in patients with malignant lymphoma. Material and Methods: Computed-tomography-guided core needle biopsies in patients with malignant lymphoma performed in the period 1996 to 2001 were evaluated retrospectively. A biopsy was considered as 'fully diagnostic' if a histological diagnosis, including the histologic subtype in the event of malignant lymphoma, was achieved and the clinical course and CT follow-up of at least 6 months confirmed the biopsy results. A biopsy was regarded as 'partly diagnostic' if histological work-up defined malignant lymphoma but not the histological subtype, and if histological diagnosis bore therapeutic relevance. Diagnostic yield was correlated with features such as size of specimen, location and depth of the target lesion, and experience of the investigator. Results: 45 biopsies were performed in 40 patients. With respect to definite histopathological diagnosis, 31 biopsies (68.9%) were diagnostic and 14 (31.1%) non-diagnostic. In 4 cases (8.8%), biopsies yielded partly diagnostic results, since therapy could be scheduled after biopsy without final sub-classification. Statistical analysis of biopsy parameters revealed that sample sizes were significantly larger in the diagnostic group. Conclusion: CT-guided biopsy can be considered as an alternative for lymphoma diagnosis and should be the first interventional procedure. The most important parameter for diagnostic success is the size of the specimen

  11. Clinical background and its relation to results of percutaneous needle biopsy of suspected bone metastasis under guidance with CT fluoroscopy

    International Nuclear Information System (INIS)

    Aoki, Jun; Koyama, Yoshinori; Morita, Hideo; Takahashi, Ayako; Nakajima, Takahito; Yagi, Akiko; Arai, Kiyokazu; Shinozaki, Tetsuya; Watanabe, Hideomi

    2005-01-01

    The purpose of this study was to investigate the clinical background of needle biopsy of suspected bone metastasis under guidance with CT fluoroscopy. During a 3-year period (from April 2000 to March 2003), 103 needle biopsies on 101 lesions of 90 patients were performed for pathological evaluation of suspected bone metastasis. The clinical course of these patients prior to biopsy and its relation to the biopsy results were retrospectively reviewed. Sixty-two patients (69% of total cases) were referred for biopsy from orthopedic surgeons, and 51 of these patients consulted orthopedic surgeons on the initial presentation. Malignancy was pathologically proved in 47 (76%) of the 62 orthopedic patients, and in 19 (68%) of the 28 patients referred from other clinicians. Thirteen (21%) of the orthopedic patients had a history of malignancy, while 22 (78%) of the non-orthopedic patients were cancer patients. Metastasis was pathologically proved in 23 (66%) of the 35 patients with a history of malignancy, while malignancy was pathologically proved in 43 (78%) of the 55 patients without known malignancy. Diagnostic accuracy of the needle bone biopsy was 96%, and its complication rate was 0.7%. In the era of CT fluoroscopy, needle biopsy for suspected bone metastasis was most frequently requested for the patients who consulted orthopedic surgeons for the occurrence of local bone pain as the initial symptom of unknown malignancy. Frequency of malignancy proved by the biopsy in those patients was as high as that in the cancer patients referred from other clinicians. (author)

  12. Multicenter study for the evaluation of a dedicated biopsy device for MR-guided vacuum biopsy of the breast

    International Nuclear Information System (INIS)

    Perlet, C.; Sittek, H.; Schneider, P.; Reiser, M.; Heinig, A.; Stets, C.; Heywang-Koebrunner, S.H.; Prat, X.; Lamarque, J.; Taourel, P.; Casselman, J.; Baath, L.; Anderson, I.

    2002-01-01

    The purpose of this multicenter study was to determine the accuracy and clinical value of a dedicated breast biopsy system which allows for MR-guided vacuum biopsy (VB) of contrast-enhancing lesions. In five European centers, MR-guided 11-gauge VB was performed on 341 lesions. In 7 cases VB was unsuccessful. This was immediately realized on postinterventional images or direct follow-up combined with histopathology-imaging correlation; thus, a false-negative diagnosis was avoided. Histology of 334 successful biopsies yielded 84 (25%) malignancies, 17 (5%) atypical ductal hyperplasias, and 233 (70%) benign entities. Verification of malignant or borderline lesions included reexcision of the biopsy cavity. Benign histologic biopsy results were verified by retrospective correlation with the pre- and postinterventional MRI and by subsequent follow-up. Our results indicate that MR-guided VB, in combination with the dedicated biopsy coil, offers the possibility to accurately diagnose even very small lesions that can only be visualized or localized by MRI. (orig.)

  13. Comparison of sonoelastography guided biopsy with systematic biopsy: impact on prostate cancer detection

    International Nuclear Information System (INIS)

    Pallwein, Leo; Struve, Peter; Aigner, Friedrich; Gradl, Johann; Schurich, Matthias; Frauscher, Ferdinand; Mitterberger, Michael; Horninger, Wolfgang; Bartsch, Georg; Pedross, Florian

    2007-01-01

    A prospective study was performed to determine the value of sonoelastography (SE) targeted biopsy for prostate cancer (PCa) detection. A series of 230 male screening volunteers was examined. Two independent examiners evaluated each subject. One single investigator performed ≤5 SE targeted biopsies into suspicious regions in the peripheral zone only. The stiffness of the lesion was displayed by SE and color-coded from red (soft) to blue (hard). Hard lesions were considered as malignant and targeted by biopsy. Subsequently, another examiner performed ten systematic biopsies. Cancer detection rates of the two techniques were compared. Cancer was detected in 81 of the 230 patients (35%), including 68 (30%) by SE targeted biopsy and in 58 (25%) by systematic biopsy. Cancer was detected by targeted biopsy alone in 23 patients (10%) and by systematic biopsy alone in 13 patients (6%). The detection rate for SE targeted biopsy cores (12.7% or 135 of 1,109 cores) was significantly better than for systematic biopsy cores (5.6% or 130 of 2,300 cores, P < 0.001). SE targeted biopsy in a patient with cancer was 2.9-fold more likely to detect PCa than systematic biopsy. SE targeted biopsy detected more cases of PCa than systematic biopsy, with fewer than half the number of biopsy cores in this prostate-specific antigen screening population. (orig.)

  14. Stereotactic core biopsy: Comparison of 11 gauge with 8 gauge vacuum assisted breast biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Venkataraman, Shambhavi, E-mail: svenkata@bidmc.harvard.edu [Department of Radiology, Beth Israel Deaconess Medical Center, 330 Brookline Avenue, Boston, MA 02215 (United States); Dialani, Vandana [Department of Radiology, Beth Israel Deaconess Medical Center, 330 Brookline Avenue, Boston, MA 02215 (United States); Gilmore, Hannah L. [Department of Pathology, UH Case Medical Center, 11100 Euclid Ave, Cleveland, OH 44106 (United States); Mehta, Tejas S. [Department of Radiology, Beth Israel Deaconess Medical Center, 330 Brookline Avenue, Boston, MA 02215 (United States)

    2012-10-15

    Purpose: The compare the performance and ability to obtain a correct diagnosis on needle biopsy between 11 gauge and 8 gauge vacuum assisted biopsy devices. Materials and methods: Hospital records of all consecutive stereotactic core biopsies performed over five years were retrospectively reviewed in compliance Health Insurance Portability and Accountability Act (HIPPA) policy and with approval from the hospital institutional review board (IRB). Pathology from core biopsy was compared with surgical pathology and/or imaging follow-up. A histological underestimation was defined if the surgical excision yielded a higher grade on pathology which changed management. Results: 828 needle core biopsies (47.5%, 393/828 with 11 gauge and 52.5%, 435/828 with 8 gauge) yielded 471 benign, 153 high risk and 204 malignant lesions. 30/193 (15.5%) 11 gauge lesions and 16/185 (8.6%) 8 gauge lesions demonstrated higher grade pathology on surgical excision. The difference in the rates of the number of correct diagnoses on core needle biopsy between 11 gauge (363/393, 92.4%) and 8 gauge (419/435, 96.3%) based on either surgical or clinical/imaging follow up and the difference in the number of discordant benign core biopsies between 11 (17/217, 7.8%) and 8 gauge (4/254, 1.6%) necessitating a surgical biopsy was significant (P = 0.013; P = 0.001). Although there were more underestimations with the 11 gauge (25/193, 13.0%) than 8 gauge (15/185, 8.1%) needle, this was not significant. Conclusion: Our study demonstrates improved performance and increased diagnostic ability of 8 gauge needle over 11 gauge in obtaining a correct diagnosis on needle biopsy.

  15. Comparison between endobronchial forceps-biopsy and cryo-biopsy by flexible

    Directory of Open Access Journals (Sweden)

    Sami El-Dahdouh

    2016-01-01

    Conclusions: We concluded that cryoprobe biopsies were more successful than forceps biopsies in the diagnosis of lung cancer. Nevertheless, further investigations are warranted to determine an efficacy of cryoprobe biopsy procedures and a rationale to use as a part of routine flexible bronchoscopy.

  16. Prostate biopsy after definitive treatment by interstitial iodine 125 implant or external beam radiation therapy

    International Nuclear Information System (INIS)

    Schellhammer, P.F.; el-Mahdi, A.M.; Higgins, E.M.; Schultheiss, T.E.; Ladaga, L.E.; Babb, T.J.

    1987-01-01

    The response to definitive radiation therapy of localized carcinoma of the prostate by iodine 125 implantation or external beam radiotherapy was monitored by examining specimens from biopsies performed after treatment. We analyzed 126 biopsy specimens obtained 18 months or more after treatment: 71 were obtained from 109 patients treated by iodine 125 and 55 from 197 patients treated by external beam radiotherapy. Thereafter, the disease status of these patients was examined at minimum 3-year intervals. No significant statistical difference was found between the negative specimen rates of the 2 treatment modalities: 46 of 71 (65 per cent) after iodine 125 implantation and 39 of 55 (71 per cent) after external beam radiotherapy were negative. To analyze the predictive value of biopsy results 103 patients whose prostatic examination results were normal at biopsy or who showed regression of tumor size and tumor induration after radiation were evaluated. The biopsy results from all patients were combined for analysis. Of 77 patients with negative biopsy specimens 16 (21 per cent) have had recurrent disease, compared to 17 of 26 (65 per cent) with positive biopsy specimens (p equals 0.00005). Of the 77 patients with negative biopsy specimens 7 (9 per cent) had local disease recurrence, compared to 12 of 26 (46 per cent) with a positive biopsy specimen (p equals 0.0001). The value of a positive specimen to predict failure remained significant with patients stratified by pre-treatment clinical stage and grade of the disease. Our results show that patients with positive specimens from the prostate who had been judged clinically by rectal examination to have responded to radiation therapy had a significantly increased incidence of local and distant failure compared to patients who had negative biopsy specimens

  17. A biomedical engineering approach to mitigate the errors of prostate biopsy.

    Science.gov (United States)

    Ahmed, Hashim Uddin; Emberton, Mark; Kepner, Gordon; Kepner, Jeremy

    2012-02-07

    The current protocol for detecting and ruling out prostate cancer involves serum PSA testing followed by sampling of the prostate using a transrectal ultrasonography (TRUS)-guided biopsy. Many specialists have discussed how PSA screening has contributed to underdetection of clinically significant prostate cancer, overdiagnosis of clinically insignificant disease and poor risk stratification; however, little consideration has been given to the role of TRUS-guided biopsy in these errors. The performance of TRUS-guided biopsy is constrained by the biomechanical attributes of the sampling strategy, resulting in suboptimal detection efficiency of each core. By using a biomedical engineering approach, a uniform grid sampling strategy could be used to improve the detection efficiency of prostate biopsy. Moreover, the calibration of the sampling can be adjusted by altering the distance between needle deployments. Our model shows that for any given number of needle trajectories, a uniform grid approach will be superior to a divergent, nonuniform strategy for the detection of clinically important disease. This is an important message that should result in a move away from divergent sampling to a uniform grid approach for prostate biopsy.

  18. Sonographically guided percutaneous muscle biopsy in diagnosis of neuromuscular disease: a useful alternative to open surgical biopsy.

    Science.gov (United States)

    O'Sullivan, Paul J; Gorman, Grainne M; Hardiman, Orla M; Farrell, Michael J; Logan, P Mark

    2006-01-01

    The purpose of this study was to evaluate the feasibility of sonographically guided percutaneous muscle biopsy in the investigation of neuromuscular disorders. Sonographically guided percutaneous needle biopsy of skeletal muscle was performed with a 14-gauge core biopsy system in 40 patients over a 24-month period. Patients were referred from the Department of Neurology under investigation for neuromuscular disorders. Sonography was used to find suitable tissue and to avoid major vascular structures. A local anesthetic was applied below skin only. A 3- to 4-mm incision was made. Three 14-gauge samples were obtained from each patient. All samples were placed on saline-dampened gauze and sent for neuropathologic analysis. As a control, we retrospectively assessed results of the 40 most recent muscle samples acquired via open surgical biopsy. With the use of sonography, 32 (80%) of 40 patients had a histologic diagnosis made via percutaneous needle biopsy. This included 26 (93%) of 28 patients with acute muscular disease and 6 (50%) of 12 patients with chronic disease. In the surgical group (all acute disease), 38 (95%) of 40 patients had diagnostic tissue attained. Sonographically guided percutaneous 14-gauge core skeletal muscle biopsy is a useful procedure, facilitating diagnosis in acute muscular disease. It provides results comparable with those of open surgical biopsy in acute muscular disease. It may also be used in chronic muscular disease but repeated or open biopsy may be needed.

  19. Complications and risk factors in transrectal ultrasound-guided prostate biopsies

    Directory of Open Access Journals (Sweden)

    Carlos Márcio Nóbrega de Jesus

    Full Text Available CONTEXT AND OBJECTIVE: Prostate biopsy is not a procedure without risk. There is concern about major complications and which antibiotics are best for routine use before these biopsies. The objective was to determine the rate of complications and the possible risk factors in prostate biopsies. DESIGN AND SETTING: Prospective study, Faculdade de Medicina de Botucatu. METHODS: Transrectal ultrasound (TRUS guided prostate biopsies were carried out in 174 patients presenting either abnormality in digital rectal examinations (DRE or levels higher than 4 ng/ml in prostate-specific antigen (PSA tests, or both. RESULTS: Hemorrhagic complications were the most common (75.3%, while infectious complications occurred in 19% of the cases. Hematuria was the most frequent type (56%. Urinary tract infection (UTI occurred in 16 patients (9.2%. Sepsis was observed in three patients (1.7%. The presence of an indwelling catheter was a risk factor for infectious complications (p < 0.05. Higher numbers of biopsies correlated with hematuria, rectal bleeding and infectious complications (p < 0.05. The other conditions investigated did not correlate with post-biopsy complications. CONCLUSIONS: Post-biopsy complications were mostly self-limiting. The rate of major complications was low, thus showing that TRUS guided prostate biopsy was safe and effective. Higher numbers of fragments taken in biopsies correlated with hematuria, rectal bleeding and infectious complications. An indwelling catheter represented a risk factor for infectious complications. The use of aspirin was not an absolute contraindication for TRUS.

  20. Outcomes of ultrasound guided renal mass biopsies.

    Science.gov (United States)

    Sutherland, Edward L; Choromanska, Agnieszka; Al-Katib, Sayf; Coffey, Mary

    2018-06-01

    The purpose of this study was to evaluate the rate of nondiagnostic ultrasound-guided renal mass biopsies (RMBs) at our institution and to determine what patient, procedural, and focal renal mass (FRM) factors were associated with nondiagnostic ultrasound-guided RMBs. Eighty-two ultrasound-guided renal mass biopsies performed between January 2014 and October 2016 were included in our study. Biopsy outcomes (diagnostic vs. nondiagnostic) and patient, procedural, and FRM characteristics were retrospectively reviewed and recorded. Univariate statistical analyses were performed to identify biopsy characteristics that were indicative of nondiagnostic biopsy. Ultrasound-guided RMBs were diagnostic in 70 out of 82 cases (85%) and non-diagnostic in 12 cases (15%). Among the diagnostic biopsies, 54 (77%) were malignant cases, 94% of which were renal cell carcinoma (RCC). Of the 12 nondiagnostic cases, the final diagnosis was RCC in 4 cases and angiomyolipoma in one case; seven of the nondiagnostic cases were lost to follow-up. A weak association (p = 0.04) was found between the number of needle passes and the biopsy outcome. None of the remaining collected RMB characteristics showed a significant correlation with a diagnostic or nondiagnostic RMB. Six patients (7%) experienced complications. Ultrasound-guided renal mass biopsy is a safe and effective method for the diagnosis of renal masses with a low rate of nondiagnostic outcomes. A nondiagnostic biopsy should not be treated as a surrogate for a diagnosis since a significant number of patients with nondiagnostic biopsies have subsequently been shown to have renal malignancies. Repeat biopsy should be considered in such cases.

  1. Prostate biopsy after ano-rectal resection: value of CT-guided trans-gluteal biopsy

    International Nuclear Information System (INIS)

    Cantwell, Colin P.; Hahn, Peter F.; Gervais, Debra A.; Mueller, Peter R.

    2008-01-01

    We describe our single-institutional experience with computed tomography (CT)-guided percutaneous transgluteal biopsy of the prostate in patients in whom transrectal ultrasound-guided biopsy is precluded by prior ano-rectal resection. Between March 1995 and April 2007, 22 patients had 34 prostate biopsies (mean age 68; mean PSA 29 ng/ml; mean follow-up 6.1 years). The charts of patients who had transgluteal biopsy were reviewed for demographic, complications and pathology. Ninety-five percent (21/22) of primary biopsies were diagnostic. Of the 21 diagnostic biopsies, 11 were positive for prostate cancer and ten were definitive benign samples. Seventy-three percent (8/11) of the patients had progressive PSA elevation that mandated 11 further prostate biopsies. Six patients had a second biopsy, one patient had a third and one patient had a fourth biopsy. Among patients who had serial biopsies, 38% (3/8) had prostate cancer. No complications or death occurred. A malignant biopsy was not significantly associated with core number (P = 0.58) or a high PSA level (P 0.15). CT-guided transgluteal biopsy of the prostate is safe and effective. (orig.)

  2. Pulmonary Masses: Initial Results of Cone-beam CT Guidance with Needle Planning Software for Percutaneous Lung Biopsy

    International Nuclear Information System (INIS)

    Braak, Sicco J.; Herder, Gerarda J. M.; Heesewijk, Johannes P. M. van; Strijen, Marco J. L. van

    2012-01-01

    Purpose: To evaluate the outcome of percutaneous lung biopsy (PLB) findings using cone-beam computed tomographic (CT) guidance (CBCT guidance) and compared to conventional biopsy guidance techniques. Methods: CBCT guidance is a stereotactic technique for needle interventions, combining 3D soft-tissue cone-beam CT, needle planning software, and real-time fluoroscopy. Between March 2007 and August 2010, we performed 84 Tru-Cut PLBs, where bronchoscopy did not provide histopathologic diagnosis. Mean patient age was 64.6 (range 24–85) years; 57 patients were men, and 25 were women. Records were prospectively collected for calculating sensitivity, specificity, positive predictive value, negative predictive value, and accuracy. We also registered fluoroscopy time, room time, interventional time, dose–area product (DAP), and complications. Procedures were divided into subgroups (e.g., location, size, operator). Results: Mean lesion diameter was 32.5 (range 3.0–93.0) mm, and the mean number of samples per biopsy procedure was 3.2 (range 1–7). Mean fluoroscopy time was 161 (range 104–551) s, room time was 34 (range 15–79) min, mean DAP value was 25.9 (range 3.9–80.5) Gy·cm −2 , and interventional time was 18 (range 5–65) min. Of 84 lesions, 70 were malignant (83.3%) and 14 were benign (16.7%). Seven (8.3%) of the biopsy samples were nondiagnostic. All nondiagnostic biopsied lesions proved to be malignant during surgical resection. The outcome for sensitivity, specificity, positive predictive value, negative predictive value, and accuracy was 90% (95% confidence interval [CI] 86–96), 100% (95% CI 82–100), 100% (95% CI 96–100), 66.7% (95% CI 55–83), and 91.7% (95% CI 86–96), respectively. Sixteen patients (19%) had minor and 2 (2.4%) had major complications. Conclusion: CBCT guidance is an effective method for PLB, with results comparable to CT/CT fluoroscopy guidance.

  3. Diagnostic Accuracy of Robot-Guided, Software Based Transperineal MRI/TRUS Fusion Biopsy of the Prostate in a High Risk Population of Previously Biopsy Negative Men

    Directory of Open Access Journals (Sweden)

    Malte Kroenig

    2016-01-01

    Full Text Available Objective. In this study, we compared prostate cancer detection rates between MRI-TRUS fusion targeted and systematic biopsies using a robot-guided, software based transperineal approach. Methods and Patients. 52 patients received a MRIT/TRUS fusion followed by a systematic volume adapted biopsy using the same robot-guided transperineal approach. The primary outcome was the detection rate of clinically significant disease (Gleason grade ≥ 4. Secondary outcomes were detection rate of all cancers, sampling efficiency and utility, and serious adverse event rate. Patients received no antibiotic prophylaxis. Results. From 52 patients, 519 targeted biopsies from 135 lesions and 1561 random biopsies were generated (total n=2080. Overall detection rate of clinically significant PCa was 44.2% (23/52 and 50.0% (26/52 for target and random biopsy, respectively. Sampling efficiency as the median number of cores needed to detect clinically significant prostate cancer was 9 for target (IQR: 6–14.0 and 32 (IQR: 24–32 for random biopsy. The utility as the number of additionally detected clinically significant PCa cases by either strategy was 0% (0/52 for target and 3.9% (2/52 for random biopsy. Conclusions. MRI/TRUS fusion based target biopsy did not show an advantage in the overall detection rate of clinically significant prostate cancer.

  4. Accuracy of Colposcopically Directed Biopsy: Results from an Online Quality Assurance Programme for Colposcopy in a Population-Based Cervical Screening Setting in Italy

    Science.gov (United States)

    Sideri, Mario; Garutti, Paola; Costa, Silvano; Cristiani, Paolo; Sassoli de Bianchi, Priscilla; Naldoni, Carlo

    2015-01-01

    Purpose. To report the accuracy of colposcopically directed biopsy in an internet-based colposcopy quality assurance programme in northern Italy. Methods. A web application was made accessible on the website of the regional Administration. Fifty-nine colposcopists out of the registered 65 logged in, viewed a posted set of 50 digital colpophotographs, classified them for colposcopic impression and need for biopsy, and indicated the most appropriate site for biopsy with a left-button mouse click on the image. Results. Total biopsy failure rate, comprising both nonbiopsy and incorrect selection of biopsy site, was 0.20 in CIN1, 0.11 in CIN2, 0.09 in CIN3, and 0.02 in carcinoma. Errors in the selection of biopsy site were stable between 0.08 and 0.09 in the three grades of CIN while decreasing to 0.01 in carcinoma. In multivariate analysis, the risk of incorrect selection of biopsy site was 1.97 for CIN2, 2.52 for CIN3, and 0.29 for carcinoma versus CIN1. Conclusions. Although total biopsy failure rate decreased regularly with increasing severity of histological diagnosis, the rate of incorrect selection of biopsy site was stable up to CIN3. In multivariate analysis, CIN2 and CIN3 had an independently increased risk of incorrect selection of biopsy site. PMID:26180805

  5. The Role of Biopsy in Pediatric Dermatopathology

    Directory of Open Access Journals (Sweden)

    Fatma Şule Afşa

    2011-09-01

    Full Text Available Background and Design: Pediatric dermatology is characterized by skin disorders which have frequencies different from those in adults. Skin biopsies are necessary for differential diagnosis and clinicopathologic correlation is very important. The aim of this study was to evaluate retrospectively the pediatric dermatology cases in whom biopsy was performed for differential diagnosis and to investigate the contribution of biopsy to diagnosis of skin disorders. Material and Methods: The cases from whom biopsy was taken in the pediatric dermatology clinic during a three-year period were evaluated retrospectively for pre-diagnoses, biopsy diagnoses, and success of biopsies.Results: Two hundred thirteen (1.7% skin biopsies had been taken from a total of 12420 patients. Henoch-Schönlein purpura, psoriasis, pityriasis lichenoides, pityriasis rosea, lichen planus, pityriasis rubra pilaris, erythema multiforme, atopic dermatitis, granuloma annulare, and pigmented purpuric dermatosis were the most frequent skin disorders diagnosed dermatopathologically. In a total of 120 (56.3% cases, the biopsy diagnosis was within the pre-diagnosis and a biopsy consistency was present. In 25 (11.7% cases, biopsy had no contribution to the differential diagnosis. An absolutely different diagnosis which was incompatible with the pre-diagnosis had been reported in 10 (4.6% cases. Conclusion: In pediatric dermatology, skin biopsy is very helpful for the differential diagnosis. An easy biopsy procedure for the patient, an effective designation of biopsy indication, a good dermatopathologic correlation and an experienced team of pediatric dermatopathology increase the success of skin biopsies.

  6. Bone lesion biopsy

    Science.gov (United States)

    Bone biopsy; Biopsy - bone ... the cut, then pushed and twisted into the bone. Once the sample is obtained, the needle is ... sample is sent to a lab for examination. Bone biopsy may also be done under general anesthesia ...

  7. Open lung biopsy

    Science.gov (United States)

    Biopsy - open lung ... An open lung biopsy is done in the hospital using general anesthesia . This means you will be asleep and ... The open lung biopsy is done to evaluate lung problems seen on x-ray or CT scan .

  8. Concurrent Alzheimer's pathology in patients with clinical normal pressure hydrocephalus: correlation of high-volume lumbar puncture results, cortical brain biopsies, and outcomes.

    Science.gov (United States)

    Pomeraniec, I Jonathan; Bond, Aaron E; Lopes, M Beatriz; Jane, John A

    2016-02-01

    Normal pressure hydrocephalus (NPH) remains most often a clinical diagnosis and has been widely considered responsive to the placement of a cerebrospinal fluid (CSF) shunt. The high incidence of patients with Alzheimer's disease (AD) with NPH symptoms leads to poorer outcomes than would be expected in patients with NPH alone. This article reviews a series of patients operated on for presumed NPH in whom preoperative high-volume lumbar puncture (HVLP) and intraoperative cortical brain biopsies were performed. The data derived from these procedures were then used to understand the incidence of AD in patients presenting with NPH symptoms and to analyze the efficacy of HVLP in patients with NPH and patients with concurrent AD (NPH+AD). A review of the outcomes of shunt surgery is provided. The cases of all patients who underwent placement of a CSF shunt for NPH from 1998 to 2013 at the University of Virginia by the senior author were retrospectively reviewed. Patients who underwent HVLP and patients who underwent cortical brain biopsies were stratified based on the biopsy results into an NPH-only group and an NPH+AD group. The HVLP results and outcomes were then compared in these 2 groups. From 1998 to 2013, 142 patients underwent shunt operations because of a preoperative clinical diagnosis of NPH. Of the patients with a shunt who had a diagnosis of NPH, 105 (74%) received HVLPs. Of 142 shunt-treated patients with NPH, 27 (19%) were determined to have concomitant Alzheimer's pathology based on histopathological findings at the time of shunting. Patients who underwent repeat biopsies had an initial positive outcome. After they clinically deteriorated, they underwent repeat biopsies during shunt interrogation, and 13% of the repeat biopsies demonstrated Alzheimer's pathology. Improvements in gait and cognition did not reach significance between the NPH and NPH+AD groups. In total, 105 patients underwent HVLP before shunt placement. In the NPH cohort, 44.6% of patients

  9. Kidney biopsy

    Science.gov (United States)

    ... the kidney (in rare cases, may require a blood transfusion) Bleeding into the muscle, which might cause soreness Infection (small risk) Alternative Names Renal biopsy; Biopsy - kidney Images Kidney anatomy ...

  10. Magnetic resonance imaging-guided biopsies may improve diagnosis in biopsy-naive men with suspicion of prostate cancer

    DEFF Research Database (Denmark)

    Winther, Mads Dochedahl; Balslev, Ingegerd; Boesen, Lars

    2017-01-01

    INTRODUCTION: The purpose of this pilot study was to investigate whether a short prostate biparametric magnetic resonance imaging (bp-MRI) protocol provides a valuable diagnostic addition for biopsy guidance in biopsy-naive men with a suspicion of prostate cancer (PCa). METHODS: A total of 62...... biopsy-naive patients referred to a systematic transrectal ultrasound biopsy (TRUS-bx) due to suspicion of PCa were prospectively enrolled. Bp-MRI was performed before biopsy. All lesions were scored according to the modified Prostate Imaging Reporting and Data System (PI-RADS) version 2. All patients...... underwent TRUS-bx followed by bp-MRI-guided biopsies (bp-MRI-bx) under MRI/TRUS image fusion from any bp-MRI suspicious lesions not obviously targeted by TRUS-bx. RESULTS: PCa was found in 42 (68%) and 32 (52%) patients by TRUS-bx and bp-MRI-bx, respectively. Bp-MRI-bx de-tected PCa in one patient who had...

  11. Percutaneous ultrasound-guided renal biopsy in children: The need for renal biopsy in pediatric patients with persistent asymptomatic microscopic hematuria

    Directory of Open Access Journals (Sweden)

    Mei-Ching Yu

    2014-12-01

    Full Text Available Background: Percutaneous renal biopsy (PRB is essential for the diagnosis, prognosis, and management of children with unknown kidney disease. In this study, the safety and efficacy of PRB is investigated, and also the common etiologies of childhood kidney disease, based on histological findings. In addition, we explored the role of PRBs in the diagnosis of children who presented with persistent asymptomatic hematuria. Methods: By chart review, from July 2005 to July 2009, a total of 99 PRBs were performed on 91 children (43 girls and 48 boys; mean age, 10.9 ± 4.4 years under ultrasound (US guidance, by a doctor, using an automated 18-gauge biopsy needle following the same protocol, at a medical center in northern Taiwan. Results: The accuracy of the histological diagnosis was excellent. The most common post-biopsy complications were perirenal hematoma (11.1% and asymptomatic gross hematuria (3.0%, respectively. Nevertheless, these complications resolved spontaneously, and none had major bleeding episodes. Histological results showed that lupus nephritis, minimal change disease, and IgA nephropathy (IgAN could be the current leading causes of childhood kidney diseases in Taiwan. Conclusions: Automated ultrasound (US-guided PRB is a safe and reliable method of assessing childhood renal disease. A recent study shows that the presence of persistent asymptomatic isolated microhematuria in adolescents is a predictive marker of future end-stage renal disease. Hence, the emphasis of renal biopsy on children with persistent asymptomatic hematuria is beneficial for the early diagnosis of IgAN or other glomerulonephritis (GN, which tends toward progressive kidney disease in adulthood without prompt therapeutic intervention.

  12. Multi-institutional Evaluation of Upper Urinary Tract Biopsy Using Backloaded Cup Biopsy Forceps, a Nitinol Basket, and Standard Cup Biopsy Forceps.

    Science.gov (United States)

    Lama, Daniel J; Safiullah, Shoaib; Patel, Roshan M; Lee, Thomas K; Balani, Jyoti P; Zhang, Lishi; Okhunov, Zhamshid; Margulis, Vitaly; Savage, Stephen J; Uchio, Edward; Landman, Jaime

    2018-04-06

    To compare the performance of 3 contemporary ureteroscopic biopsy devices for the histopathologic diagnosis of upper tract urothelial carcinoma (UTUC). We retrospectively reviewed 145 patients who underwent 182 urothelial biopsies using 2.4F backloaded cup biopsy forceps, a nitinol basket, or 3F standard cup biopsy forceps at 3 tertiary academic centers between 2011 and 2016. Experienced genitourinary pathologists provided an assessment of each specimen without knowledge of the device used for biopsy. For patients who underwent nephroureterectomy without neoadjuvant chemotherapy within 3 months of biopsy-proven UTUC diagnosis, the biopsy grade was compared with both the grade and stage of the surgical specimen. Biopsy utilization varied among the 3 institutions (P cup forceps was rated similarly to the nitinol basket (P >.05) and was favored over standard cup forceps specimens. Grade concordance was not affected by specimen size (P >.05), morphology (P >.1), or location (P >.5). No difference existed among the devices in the rate of acquiring a grade concordant biopsy; however, the backloaded cup forceps provided concordant biopsies that could be distinguished as low- and high-grade (P = .02). The backloaded cup forceps and nitinol basket obtained a higher quality urothelial specimen compared with standard cup forceps. Ureteroscopic biopsy device selection did not significantly impact the accuracy of the histologic diagnosis of UTUC. Copyright © 2018 Elsevier Inc. All rights reserved.

  13. Liver CT-guided aspirative biopsies

    International Nuclear Information System (INIS)

    Santos, Gilda da Cunha; Carvalho, Leda Viegas de; Chojniak, Rubens; Morini, Sandra Regina

    1996-01-01

    Sixty-eight CT-guided aspirative biopsies of hepatic nodules were performed at A.C. Camargo Hospital, Sao Paulo, Brazil, from 1992 to 1995. The cases were distributed as follow: 44(64.7%) with a positive diagnosis for neoplastic cells, 6(8.8%) with a negative diagnosis, and 14 (20.5%) with insufficient material. Of the positive cases (primary neoplasias and metastases), the cytological diagnosis was achieved in 39 cases. There were 36 cases of carcinoma (7 hepato carcinomas, 18 adenocarcinomas, 1 small cell carcinoma and 10 cases of unspecified differentiation), 2 cases of melanoma and 1 case of melanoma and 1 case of sarcoma. The correlation with histopathological exams showed no false positive cases and concordance between cytological and histopathological diagnosis. The results demonstrate that CT-guided aspirative biopsy of hepatic nodules permits a rapid diagnosis of neoplastic lesions, especially for the evaluation of metastases. (author)

  14. Bone marrow trephine biopsies: A single centre experience in Eastern India

    Directory of Open Access Journals (Sweden)

    Sima Chauhan

    2017-01-01

    Full Text Available Introduction: Bone marrow aspiration (BMA and trephine biopsy are indispensable diagnostic tools for evaluating hematological and nonhematological disorders in the present era. However, trephine biopsy demands greater technical skills and expertise as compared to BMA alone. In this study, we have analyzed the advantages of carrying out trephine biopsy along with BMA in the same sitting. Materials and Methods: This is a prospective observational study carried out from June 2014 to May 2015. The patients attending hematology and medicine outdoors were screened by detailed clinical examination, laboratory investigations including complete blood counts, peripheral smear, and whenever indicated were subjected to BMA and trephine biopsy in the same sitting. Results: Out of total 570 aspirations and trephine biopsies done, 8% showed inadequate aspirates and diagnosis was based only on biopsy findings. Confirmatory diagnosis of aplastic anemia was done on trephine biopsy in 100% cases. Fifty percent cases of granulomas and 33.3% cases of metastasis were missed in aspiration smears. They were diagnosed on trephine biopsy. All cases of myelofibrosis required trephine biopsy for diagnosis, but aspiration alone was adequate for diagnosis in majority of acute leukemias. Conclusion: Trephine biopsy is mandatory for diagnosis of aplastic anemia, myelofibrosis, and for staging of lymphomas. It specially carries diagnostic value in cases of dry tap and bloody aspirates. Aspiration is simple, has high specificity, and is especially useful for nutritional anemia, immune thrombocytopenia, acute leukemia, and multiple myeloma.

  15. CT-guided biopsy with cutting-edge needle for the diagnosis of malignant lymphoma: Experience of 267 biopsies

    International Nuclear Information System (INIS)

    Agid, R.; Sklair-Levy, M.; Bloom, A.I.; Lieberman, S.; Polliack, A.; Ben-Yehuda, D.; Sherman, Y.; Libson, E.

    2003-01-01

    AIM: We performed a retrospective study of 267 core needle aspiration biopsies in order to estimate the accuracy of CT-guided aspiration core needle biopsies for the diagnosis and subsequent treatment of malignant lymphoma. MATERIALS AND METHODS: Between 1989 and 1999, 267 CT-guided core needle biopsies were performed in 241 patients with either primary or recurrent malignant lymphoma. Patients age ranged from 4--88 years. One hundred and sixty-six (62.2%) nodal and 101 (37.8%) extranodal aspiration biopsies were performed using either 18 G or 20 G Turner needles. Statistical method used was Chi-square analysis. RESULTS: An accurate histological diagnosis was made in 199 (82.5%) patients, the remaining 42 (17.4%) patients had non-diagnostic CT biopsies. Thirty-seven of them were diagnosed by a surgical biopsy, four by bone marrow biopsy and in one patient by paracentesis. One hundred and seventy-nine patients had non-Hodgkin's lymphoma (NHL) and 62 had Hodgkin's disease (HD); 23 (9.54%) patients underwent repeated CT biopsy which was diagnostic in 17 (73.9%) and non-diagnostic in six (26%). CONCLUSION: CT-guided aspiration core biopsies were sufficient to establish a diagnosis in lymphoproliferative disorders in 82.5% of cases. In the light of this experience we suggest that imaging-guided core needle biopsy be used as the first step in the work up of many patients with lymphoma Agid,R. et al. (2003). Clinical Radiology58, 143-147

  16. Prostate biopsy with image fusion: system validation and clinical results (abstract)

    NARCIS (Netherlands)

    Kruecker, J.; Kadoury, S.; Xu, S.; Turkbey, B.; Choyke, P.; Pinto, P.; Wood, B.

    2011-01-01

    Purpose Prostate cancer (PCA) is the second most frequent cause of cancer-related death in men in the United States and Europe. Transrectal ultrasound (TRUS) guided systematic prostate biopsy is the standard of care for detection and diagnosis of PCA. However, due to inadequate visualization of PCA

  17. [Muscle biopsy in children: Usefulness in 2012].

    Science.gov (United States)

    Cuisset, J-M; Maurage, C-A; Carpentier, A; Briand, G; Thévenon, A; Rouaix, N; Vallée, L

    2013-01-01

    Muscle biopsy is a mainstay diagnostic tool for investigating neuromuscular disorders in children. We report the yield of pediatric muscle biopsy in a population of 415 children by a retrospective study of 419 biopsies performed between 1/01/2000 and 31/12/2009 in a neuropediatric department, including mitochondrial respiratory chain analysis for 87 children. Two hundred and fifty-five biopsies were from boys (61%) 164 from girls (39%). Their mean age at biopsy was 6.5years; 155 (37%) biopsies were obtained before the child was 5years old. Final histopathological diagnoses were: congenital myopathy (n=193, including 15 structural congenital myopathies); progressive muscular dystrophy (n=75 [18%] including 57 dystrophinopathies); congenital muscular dystrophy (n=17, including six primary merosinopathies); dermatomyositis (n=11); spinal muscular atrophy (n=9, including six atypical spinal muscular atrophies); metabolic myopathy (n=32, including 19 mitochondrial myopathies); encephalomyopathy (n=53 [13%], including 27 with a mitochondrial respiratory chain defect). Pathological diagnosis remained undetermined in 16 cases. In 184 patients (44%), the muscle biopsy revealed specific histopathological anomalies (dystrophic process; specific ultrastructural abnormalities; perifascicular atrophy; neurogenic atrophy; metabolic anomalies) enabling a precise etiological diagnosis. For 85% of progressive muscular dystrophies, the biopsy resulted in a genetic diagnosis after identification of the protein defect. In 15% of the congenital myopathies, histopathological anomalies focused attention on one or several genes. Concerning dystrophinopathies, quantification of dystrophin deficiency on the biopsy specimen contributed to the definition of the clinical phenotype: Duchenne, or Becker. In children with a myopathy, muscle biopsy is often indispensable to establish the etiological diagnosis. Based on the results from this series, muscle biopsy can provide a precise

  18. Prostate biopsy

    Science.gov (United States)

    ... give the cells a grade called a Gleason score . This helps predict how fast the cancer will ... TRUS); Stereotactic transperineal prostate biopsy (STPB) Images Male reproductive anatomy References Babayan RK, Katz MH. Biopsy prophylaxis, ...

  19. Ocular Manifestations of Biopsy-Proven Pulmonary Sarcoidosis in Korea

    Directory of Open Access Journals (Sweden)

    Seung Yong Choi

    2018-01-01

    Full Text Available Purpose. To investigate the clinical features and ocular manifestations of biopsy-proven pulmonary sarcoidosis in Korea. Methods. 55 patients diagnosed with pulmonary sarcoidosis by bronchoscopic or excisional biopsy were included. By retrospective clinical chart review, we investigated features of uveitis, ocular and systemic treatments, visual acuity, angiotensin-converting enzyme level, chest radiography, and pulmonary function tests. Clinical features were analyzed by presence of uveitis, site of biopsy, and first manifested sign of sarcoidosis. Results. The group with uveitis (n=39 presented with higher systemic (71.8% and immunosuppressive treatment rates (35.9% than the group without uveitis (31.3%, 0%, resp. (P=0.007, P=0.005, resp.. There were no significant differences in clinical features, including systemic treatment rate, by type of biopsy. Of 39 patients with uveitis, the group with ocular manifestation as a first sign of sarcoidosis showed higher systemic and immunosuppressive treatment rates (88.9%, 55.6% compared to the group with pulmonary manifestation as a first sign (57.1%, 19.0% (P=0.037, P=0.018, resp.. Conclusions. In patients with biopsy-proven pulmonary sarcoidosis, the presence of ocular involvement and uveitis as a first sign could be significant factors associated with higher systemic treatment rate, especially with immunosuppressive agents. Biopsy site determined by location and size had no influence on clinical features.

  20. MRI-Targeted or Standard Biopsy for Prostate-Cancer Diagnosis.

    Science.gov (United States)

    Kasivisvanathan, Veeru; Rannikko, Antti S; Borghi, Marcelo; Panebianco, Valeria; Mynderse, Lance A; Vaarala, Markku H; Briganti, Alberto; Budäus, Lars; Hellawell, Giles; Hindley, Richard G; Roobol, Monique J; Eggener, Scott; Ghei, Maneesh; Villers, Arnauld; Bladou, Franck; Villeirs, Geert M; Virdi, Jaspal; Boxler, Silvan; Robert, Grégoire; Singh, Paras B; Venderink, Wulphert; Hadaschik, Boris A; Ruffion, Alain; Hu, Jim C; Margolis, Daniel; Crouzet, Sébastien; Klotz, Laurence; Taneja, Samir S; Pinto, Peter; Gill, Inderbir; Allen, Clare; Giganti, Francesco; Freeman, Alex; Morris, Stephen; Punwani, Shonit; Williams, Norman R; Brew-Graves, Chris; Deeks, Jonathan; Takwoingi, Yemisi; Emberton, Mark; Moore, Caroline M

    2018-05-10

    Multiparametric magnetic resonance imaging (MRI), with or without targeted biopsy, is an alternative to standard transrectal ultrasonography-guided biopsy for prostate-cancer detection in men with a raised prostate-specific antigen level who have not undergone biopsy. However, comparative evidence is limited. In a multicenter, randomized, noninferiority trial, we assigned men with a clinical suspicion of prostate cancer who had not undergone biopsy previously to undergo MRI, with or without targeted biopsy, or standard transrectal ultrasonography-guided biopsy. Men in the MRI-targeted biopsy group underwent a targeted biopsy (without standard biopsy cores) if the MRI was suggestive of prostate cancer; men whose MRI results were not suggestive of prostate cancer were not offered biopsy. Standard biopsy was a 10-to-12-core, transrectal ultrasonography-guided biopsy. The primary outcome was the proportion of men who received a diagnosis of clinically significant cancer. Secondary outcomes included the proportion of men who received a diagnosis of clinically insignificant cancer. A total of 500 men underwent randomization. In the MRI-targeted biopsy group, 71 of 252 men (28%) had MRI results that were not suggestive of prostate cancer, so they did not undergo biopsy. Clinically significant cancer was detected in 95 men (38%) in the MRI-targeted biopsy group, as compared with 64 of 248 (26%) in the standard-biopsy group (adjusted difference, 12 percentage points; 95% confidence interval [CI], 4 to 20; P=0.005). MRI, with or without targeted biopsy, was noninferior to standard biopsy, and the 95% confidence interval indicated the superiority of this strategy over standard biopsy. Fewer men in the MRI-targeted biopsy group than in the standard-biopsy group received a diagnosis of clinically insignificant cancer (adjusted difference, -13 percentage points; 95% CI, -19 to -7; Pprostate cancer who had not undergone biopsy previously. (Funded by the National Institute for

  1. Visually directed vs. software-based targeted biopsy compared to transperineal template mapping biopsy in the detection of clinically significant prostate cancer.

    Science.gov (United States)

    Valerio, Massimo; McCartan, Neil; Freeman, Alex; Punwani, Shonit; Emberton, Mark; Ahmed, Hashim U

    2015-10-01

    analysis showed similar results. Based on these findings, a paired cohort study enrolling at least 257 men would verify whether this difference is statistically significant. The diagnostic ability of software-based targeted biopsy and visually directed targeted biopsy seems almost comparable, although utility and efficiency both seem to be slightly in favor of the software-based strategy. Ongoing trials are sufficiently powered to prove or disprove these findings. Copyright © 2015 Elsevier Inc. All rights reserved.

  2. High-resolution respirometry of fine-needle muscle biopsies in pre-manifest Huntington's disease expansion mutation carriers shows normal mitochondrial respiratory function.

    Directory of Open Access Journals (Sweden)

    Eva Buck

    Full Text Available Alterations in mitochondrial respiration are an important hallmark of Huntington's disease (HD, one of the most common monogenetic causes of neurodegeneration. The ubiquitous expression of the disease causing mutant huntingtin gene raises the prospect that mitochondrial respiratory deficits can be detected in skeletal muscle. While this tissue is readily accessible in humans, transgenic animal models offer the opportunity to cross-validate findings and allow for comparisons across organs, including the brain. The integrated respiratory chain function of the human vastus lateralis muscle was measured by high-resolution respirometry (HRR in freshly taken fine-needle biopsies from seven pre-manifest HD expansion mutation carriers and nine controls. The respiratory parameters were unaffected. For comparison skeletal muscle isolated from HD knock-in mice (HdhQ111 as well as a broader spectrum of tissues including cortex, liver and heart muscle were examined by HRR. Significant changes of mitochondrial respiration in the HdhQ knock-in mouse model were restricted to the liver and the cortex. Mitochondrial mass as quantified by mitochondrial DNA copy number and citrate synthase activity was stable in murine HD-model tissue compared to control. mRNA levels of key enzymes were determined to characterize mitochondrial metabolic pathways in HdhQ mice. We demonstrated the feasibility to perform high-resolution respirometry measurements from small human HD muscle biopsies. Furthermore, we conclude that alterations in respiratory parameters of pre-manifest human muscle biopsies are rather limited and mirrored by a similar absence of marked alterations in HdhQ skeletal muscle. In contrast, the HdhQ111 murine cortex and liver did show respiratory alterations highlighting the tissue specific nature of mutant huntingtin effects on respiration.

  3. 11-gauge vacuum assisted directional biopsy of breast calcifications, using upright stereotactic guidance

    International Nuclear Information System (INIS)

    Nisbet, A.P.; Borthwick-Clarke, A.; Scott, N.

    2000-01-01

    To assess the use of a prototype vacuum assisted biopsy device on a standard upright mammography unit, using a slightly modified digital stereotactic add-on component. A group comprised of 42 sequential patients, who had been recalled from an asymptomatic mammographic screening programme, were studied. All 42 were recalled for assessment of small clusters of microcalcification, graded as indeterminate. Group 1 (21 patients) were biopsied using 14-gauge automated large core needle biopsy. Group 2 (21 patients) were biopsied using 11-gauge vacuum assisted biopsy. Both groups had mammographic guidance on the same upright mammographic unit (Siemens 3000), with Opdima Digital Stereotactic add-on. A total of 86% of specimen radiographs in Group 2 patients (vacuum assisted biopsy) showed successful sampling of the calcifications, compared to 62% of Group 1 patients (14-gauge automated large core biopsies). This study shows that vacuum assisted biopsy is possible using upright stereotactic mammography units. The technique shows promise as a biopsy tool, offering larger cores compared to 14-gauge automated large core biopsy, while requiring less space and lower purchase price compared to dedicated prone biopsy tables. The technique also offers access to biopsy in patients with posterior lesions and for patients who cannot tolerate prone positioning

  4. Percutaneous CT-guided biopsy for lung lesions 1 cm or smaller: the technique, results and complication

    International Nuclear Information System (INIS)

    Song, Chi Sung

    2006-01-01

    The author wanted to assess the diagnostic accuracy and safety of percutaneous biopsy for lung lesions 1 cm or smaller; the biopsies were performed on the basis of the modified coaxial technique under CT guidance. Thirty-five patients (22 men and 13 women) 23-76 years old (average age: 56.8 years) with lung lesions 1 cm or smaller underwent CT-guided percutaneous biopsy. Fifteen patients had underlying primary malignancies. After an 18 G guiding cannula was introduced to the border of the small lung lesion via the modified coaxial technique, fine-needle aspiration biopsy with 21 G needle and core tissue biopsies with 19.5 G or 20 G biopsy guns were performed through the lumen of the guiding cannula. The core tissue biopsies were finished after 6 macroscopic core tissue specimens were obtained. When the needle hit the eccentric portion of the small lung lesion, a 'fanning-out' technique with using the guiding cannula was applied to get multiple core tissue specimens from the small lung lesion. The diagnostic accuracy of this method was evaluated and the complications were reviewed. Both the cytopathologic and histopathologic specimens were obtained in all 35 cases. The fanning-out technique was necessary in 15 cases (43%) for obtaining six core tissue specimens from small lesions. The final diagnoses were 17 malignant lesions and 18 benign lesions. Sixteen lesions were true-positive, eighteen were true-negative, none was false-positive and one was false-negative. The overall diagnostic accuracy was 97%. The sensitivity for detecting malignancy and the specificity for benign lesion were 94% and 100%, respectively. The positive and negative predictive values were 100% and 95%, respectively. The diagnostic ability to characterize the specific cell type of the malignant lesion was 94% (16 of 17), that for the benign lesions was 83% (15 of 18), and overall diagnostic ability was 89% (31 of 35). Five patients (14%) developed a pneumopthorax, and one of them (3%) received

  5. Bone biopsy needles. Mechanical properties, needle design and specimen quality

    International Nuclear Information System (INIS)

    Keulers, Annika; Penzkofer, T.; Cunha-Cruz, V.C.; Bruners, P.; Helmholtz Inst. fuer biomedizinische Technik, Aachen; Braunschweig, T.; Schmitz-Rode, T.; Mahnken, A.; Helmholtz Inst. fuer biomedizinische Technik, Aachen

    2011-01-01

    To quantitatively analyze differences in mechanical properties, needle design including signs of wear, subjective handling and specimen quality of bone biopsy needles. Materials and Methods: In this study 19 different bone biopsy systems (total 38; 2 /type) were examined. With each biopsy needle five consecutive samples were obtained from vertebral bodies of swine. During puncture a force-torques sensor measured the mechanical properties and subjective handling was assessed. Before and after each biopsy the needles were investigated using a profile projector and signs of wear were recorded. Afterwards, a pathologist semi-quantitatively examined the specimen regarding sample quality. The overall evaluation considered mechanical properties, needle wear, subjective handling and sample quality. Differences were assessed for statistical significance using ANOVA and t-test. Results: Needle diameter (p = 0.003) as well as needle design (p = 0.008) affect the mechanical properties significantly. Franseen design is significantly superior to other needle designs. Besides, length reduction recorded by the profile projector, as a quality criterion showed notable distinctions in between the needle designs. Conclusion: Bone biopsy needles vary significantly in performance. Needle design has an important influence on mechanical properties, handling and specimen quality. Detailed knowledge of those parameters would improve selecting the appropriate bone biopsy needle. (orig.)

  6. The value of diagnostic hysteroscopy with biopsy in the preoperative of endometrial ablation

    Directory of Open Access Journals (Sweden)

    Salete Yatabe

    2011-12-01

    Full Text Available Objective: To assess the value of diagnostic hysteroscopy with biopsy in the preoperative preparation for endometrial ablation. Methods: It was a prospective non-randomized study conducted at the division of Gynecologic Endoscopy of Hospital do Servidor Público Estadual “Francisco Morato de Oliveira” from March 2007 to May 2009. A total of 45 patients with abnormal uterine bleeding, and referred to endometrial ablation were included. All women underwent a diagnostic hysteroscopy, and were treated with a GnRH analogous – goserelin – 10.8 mg before surgery. The endometrial ablation was performed with a surgical resectoscope. Patients were submitted to one directed endometrial biopsy, one guided endometrial biopsy with Novak curette, and to endometrial ablation, which was considered as reference for pathological examination with samples from the biopsies. Data were analyze using the SPSS-v16 software, and considered significance at p = 0.05. Results: The mean age of women was 44.20 years (33-56, parity of 2.67 (0-9, uterus size of 139.99 calculated in cc (42-278, and the mean duration of symptoms was 3.68 years (0.5-15. The guided endometrial biopsy showed sensitivity of 80% for endometrium without atypia, and the directed endometrial biopsy had sensitivity of 60%. For proliferative endometrium the directed endometrial biopsy showed sensitivity of 76 and 100% for secretory endometrium, which was higher than the guided endometrial biopsy with 53 and 50%, respectively. Conclusion: The directed biopsy before endometrial ablation had lower sensitivity than guided biopsy for endometrium without atypia, however it was higher for proliferative and secretory endometrium.

  7. Percutaneous biopsy of malignant hepatic tumor in patients with bleeding tendency : usefulness of gelfoam plugging up the biopsy track

    International Nuclear Information System (INIS)

    Yoon, Hye Ran; Kwak, Byung Kook; Choi, Chi Hoon; Park, Yong Ok; Yang, Keun Myeong; Seo, Ja Young; Lee, Shin Hyung; Lee, Chang Joon; Shim, Hyung Jin

    1998-01-01

    To plug the biopsy site in eight patients with coagulopathy who had undergone percutaneous liver biopsy. To this end, gelfoam cartridge was used as a sealant. Materials and Methods: Using an 18G Tru-Cut-type disposable automated biopsy gun(Soo Ho Medi-tech, Seoul, Korea) and under US guidance, eight patients underwent percutaneous liver biopsy. After the gun had fired, the biopsy specimen in the inner stylet was retrieved while the outer cannula was held in place ; the cannula was then used to plug the biopsy tracks with gelfoam, using two or three cartridges. If bleeding occurred, this was controlled by the use of more gelfoam cartridges. Results:Diagnostic target tissue was obtained in seven of the eight patients(87.5%). Hepatocellular carcinoma was diagnosed in five cases and metastatic cancer in two. Profuse bleeding was observed in one patient(12.5%) and resolved by gelfoam plugging. Conclusion: We believe that in patients with coagulopathy who are required to undergo liver biopsy plugging the liver biopsy track with gelfoam cartridge is a simple, safe and useful method

  8. Image-guided procedures in brain biopsy.

    Science.gov (United States)

    Fujita, K; Yanaka, K; Meguro, K; Narushima, K; Iguchi, M; Nakai, Y; Nose, T

    1999-07-01

    Image-guided procedures, such as computed tomography (CT)-guided stereotactic and ultrasound-guided methods, can assist neurosurgeons in localizing the relevant pathology. The characteristics of image-guided procedures are important for their appropriate use, especially in brain biopsy. This study reviewed the results of various image-guided brain biopsies to ascertain the advantages and disadvantages. Brain biopsies assisted by CT-guided stereotactic, ultrasound-guided, Neuronavigator-guided, and the combination of ultrasound and Neuronavigator-guided procedures were carried out in seven, eight, one, and three patients, respectively. Four patients underwent open biopsy without a guiding system. Twenty of 23 patients had a satisfactory diagnosis after the initial biopsy. Three patients failed to have a definitive diagnosis after the initial procedure, one due to insufficient volume sampling after CT-guided procedure, and two due to localization failure by ultrasound because the lesions were nonechogenic. All patients who underwent biopsy using the combination of ultrasound and Neuronavigator-guided methods had a satisfactory result. The CT-guided procedure provided an efficient method of approaching any intracranial target and was appropriate for the diagnosis of hypodense lesions, but tissue sampling was sometimes not sufficient to achieve a satisfactory diagnosis. The ultrasound-guided procedure was suitable for the investigation of hyperdense lesions, but was difficult to localize nonechogenic lesions. The combination of ultrasound and Neuronavigator methods improved the diagnostic accuracy even in nonechogenic lesions such as malignant lymphoma. Therefore, it is essential to choose the most appropriate guiding method for brain biopsy according to the radiological nature of the lesions.

  9. Incremental diagnostic value of targeted biopsy using mpMRI-TRUS fusion versus 14-fragments prostatic biopsy. A prospective controlled study

    International Nuclear Information System (INIS)

    Mariotti, Guilherme C.; Falsarella, Priscila M.; Garcia, Rodrigo G.; Queiroz, Marcos R.G.; Lemos, Gustavo C.; Baroni, Ronaldo H.

    2018-01-01

    To compare the incremental diagnostic value of targeted biopsy using real-time multiparametric magnetic resonance imaging and transrectal ultrasound (mpMRI-TRUS) fusion to conventional 14-cores biopsy. Uni-institutional, institutional review board (IRB) approved prospective blinded study comparing TRUS-guided random and targeted biopsy using mpMRI-TRUS fusion, in 100 consecutive men. We included men with clinical-laboratorial suspicious for prostate cancer and Likert score ≥ 3 mp-MRI. Patients previously diagnosed with prostate cancer were excluded. All patients were submitted to 14-cores TRUS-guided biopsy (mpMRI data operator-blinded), followed by targeted biopsy using mpMRI-TRUS fusion. There was an overall increase in cancer detection rate, from 56% with random technique to 62% combining targeted biopsy using mpMRI-TRUS fusion; incremental diagnosis was even more relevant for clinically significant lesions (Gleason ≥ 7), diagnosing 10% more clinically significant lesions with fusion biopsy technique. Diagnosis upgrade occurred in 5 patients that would have negative results in random biopsies and had clinically significant tumours with the combined technique, and in 5 patients who had the diagnosis of significant tumours after fusion biopsy and clinically insignificant tumours in random biopsies(p=0.0010). Targeted biopsy using mpMRI-TRUS fusion has incremental diagnostic value in comparison to conventional random biopsy, better detecting clinically significant prostate cancers. (orig.)

  10. Incremental diagnostic value of targeted biopsy using mpMRI-TRUS fusion versus 14-fragments prostatic biopsy. A prospective controlled study

    Energy Technology Data Exchange (ETDEWEB)

    Mariotti, Guilherme C.; Falsarella, Priscila M.; Garcia, Rodrigo G.; Queiroz, Marcos R.G. [Hospital Israelita Albert Einstein, Department of Interventional Radiology, Sao Paulo (Brazil); Lemos, Gustavo C. [Hospital Israelita Albert Einstein, Department of Urology, Sao Paulo (Brazil); Baroni, Ronaldo H. [Hospital Israelita Albert Einstein, Department of Radiology, Sao Paulo (Brazil)

    2018-01-15

    To compare the incremental diagnostic value of targeted biopsy using real-time multiparametric magnetic resonance imaging and transrectal ultrasound (mpMRI-TRUS) fusion to conventional 14-cores biopsy. Uni-institutional, institutional review board (IRB) approved prospective blinded study comparing TRUS-guided random and targeted biopsy using mpMRI-TRUS fusion, in 100 consecutive men. We included men with clinical-laboratorial suspicious for prostate cancer and Likert score ≥ 3 mp-MRI. Patients previously diagnosed with prostate cancer were excluded. All patients were submitted to 14-cores TRUS-guided biopsy (mpMRI data operator-blinded), followed by targeted biopsy using mpMRI-TRUS fusion. There was an overall increase in cancer detection rate, from 56% with random technique to 62% combining targeted biopsy using mpMRI-TRUS fusion; incremental diagnosis was even more relevant for clinically significant lesions (Gleason ≥ 7), diagnosing 10% more clinically significant lesions with fusion biopsy technique. Diagnosis upgrade occurred in 5 patients that would have negative results in random biopsies and had clinically significant tumours with the combined technique, and in 5 patients who had the diagnosis of significant tumours after fusion biopsy and clinically insignificant tumours in random biopsies(p=0.0010). Targeted biopsy using mpMRI-TRUS fusion has incremental diagnostic value in comparison to conventional random biopsy, better detecting clinically significant prostate cancers. (orig.)

  11. Diagnosing pancreatic cancer: the role of percutaneous biopsy and CT

    International Nuclear Information System (INIS)

    Amin, Z.; Theis, B.; Russell, R.C.G.; House, C.; Novelli, M.; Lees, W.R.

    2006-01-01

    Aims: To determine the sensitivity and complications of percutaneous biopsy of pancreatic masses, and whether typical computed tomography (CT) features of adenocarcinoma can reliably predict this diagnosis. Materials and methods: A 5 year retrospective analysis of percutaneous core biopsies of pancreatic masses and their CT features was undertaken. Data were retrieved from surgical/pathology databases; medical records and CT reports and images. Results: Three hundred and three patients underwent 372 biopsies; 56 of 87 patients had repeat biopsies. Malignancy was diagnosed in 276 patients, with ductal adenocarcinoma in 259 (85%). Final sensitivity of percutaneous biopsy for diagnosing pancreatic neoplasms was 90%; for repeat biopsy it was 87%. Complications occurred in 17 (4.6%) patients, in three of whom the complications were major (1%): one abscess, one duodenal perforation, one large retroperitoneal bleed. CT features typical of ductal adenocarcinoma were: hypovascular pancreatic mass with bile and/or pancreatic duct dilatation. Atypical CT features were: isodense or hypervascular mass, calcification, non-dilated ducts, cystic change, and extensive lymphadenopathy. Defining typical CT features of adenocarcinoma as true-positives, CT had a sensitivity of 68%, specificity of 95%, positive predictive value (PPV) of 98%, and negative predictive value of 41% for diagnosing pancreatic adenocarcinoma. Conclusion: Final sensitivity of percutaneous biopsy for establishing the diagnosis was 90%. CT features typical of pancreatic adenocarcinoma had high specificity and PPV. On some occasions, especially in frail patients with co-morbidity, it might be reasonable to assume a diagnosis of pancreatic cancer if CT features are typical, and biopsy only if CT shows atypical features

  12. Diagnosing pancreatic cancer: the role of percutaneous biopsy and CT

    Energy Technology Data Exchange (ETDEWEB)

    Amin, Z.; Theis, B.; Russell, R.C.G.; House, C.; Novelli, M.; Lees, W.R

    2006-12-15

    Aims: To determine the sensitivity and complications of percutaneous biopsy of pancreatic masses, and whether typical computed tomography (CT) features of adenocarcinoma can reliably predict this diagnosis. Materials and methods: A 5 year retrospective analysis of percutaneous core biopsies of pancreatic masses and their CT features was undertaken. Data were retrieved from surgical/pathology databases; medical records and CT reports and images. Results: Three hundred and three patients underwent 372 biopsies; 56 of 87 patients had repeat biopsies. Malignancy was diagnosed in 276 patients, with ductal adenocarcinoma in 259 (85%). Final sensitivity of percutaneous biopsy for diagnosing pancreatic neoplasms was 90%; for repeat biopsy it was 87%. Complications occurred in 17 (4.6%) patients, in three of whom the complications were major (1%): one abscess, one duodenal perforation, one large retroperitoneal bleed. CT features typical of ductal adenocarcinoma were: hypovascular pancreatic mass with bile and/or pancreatic duct dilatation. Atypical CT features were: isodense or hypervascular mass, calcification, non-dilated ducts, cystic change, and extensive lymphadenopathy. Defining typical CT features of adenocarcinoma as true-positives, CT had a sensitivity of 68%, specificity of 95%, positive predictive value (PPV) of 98%, and negative predictive value of 41% for diagnosing pancreatic adenocarcinoma. Conclusion: Final sensitivity of percutaneous biopsy for establishing the diagnosis was 90%. CT features typical of pancreatic adenocarcinoma had high specificity and PPV. On some occasions, especially in frail patients with co-morbidity, it might be reasonable to assume a diagnosis of pancreatic cancer if CT features are typical, and biopsy only if CT shows atypical features.

  13. False Negative Fine Needle Aspiration Biopsy Results in Primary Thyroid Lymphoma

    Energy Technology Data Exchange (ETDEWEB)

    Kim, In Joong; Kim, Eun Kyung; Koh, Myoung Ju; Kwak, Jin Young; Moon, Hee Jung [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2012-06-15

    Ultrasonography-guided fine needle aspiration biopsy (US-FNA) is one of the methods used to diagnose thyroid lymphoma, but it has a relatively high false-negative rate. The authors report a case of a primary thyroid lymphoma associated with underlying lymphocytic thyroiditis that was initially misdiagnosed as lymphocytic thyroiditis based on US-FNA findings

  14. Web-based thyroid imaging reporting and data system: Malignancy risk of atypia of undetermined significance or follicular lesion of undetermined significance thyroid nodules calculated by a combination of ultrasonography features and biopsy results.

    Science.gov (United States)

    Choi, Young Jun; Baek, Jung Hwan; Shin, Jung Hee; Shim, Woo Hyun; Kim, Seon-Ok; Lee, Won-Hong; Song, Dong Eun; Kim, Tae Yong; Chung, Ki-Wook; Lee, Jeong Hyun

    2018-05-13

    The purpose of this study was to construct a web-based predictive model using ultrasound characteristics and subcategorized biopsy results for thyroid nodules of atypia of undetermined significance/follicular lesion of undetermined significance (AUS/FLUS) to stratify the risk of malignancy. Data included 672 thyroid nodules from 656 patients from a historical cohort. We analyzed ultrasound images of thyroid nodules and biopsy results according to nuclear atypia and architectural atypia. Multivariate logistic regression analysis was performed to predict whether nodules were diagnosed as malignant or benign. The ultrasound features, including spiculated margin, marked hypoechogenicity, calcifications, biopsy results, and cytologic atypia, showed significant differences between groups. A 13-point risk scoring system was developed, and the area under the curve (AUC) of the receiver operating characteristic (ROC) curve of the development and validation sets were 0.837 and 0.830, respectively (http://www.gap.kr/thyroidnodule_b3.php). We devised a web-based predictive model using the combined information of ultrasound characteristics and biopsy results for AUS/FLUS thyroid nodules to stratify the malignant risk. © 2018 Wiley Periodicals, Inc.

  15. La biopsie prostatique

    OpenAIRE

    DJEDOUI, MERIEM

    2013-01-01

    La preuve d'un cancer de la prostate est apportée par la biopsie prostatique. Malheureusement, une biopsie négative, bien que rassurante, ne suffit pas à exclure un noyau cancéreux à côté duquel l'aiguille est passée. L'urologue peut être amené à proposer une nouvelle biopsie, en augmentant, s'il le faut, le nombre de prélèvements de tissu prostatique. Ayant connu Le but d'une biopsie prostatique, le patient pourrait maintenant décider d'entrer dans d'autres alternatives qui...

  16. Results and complications of CT-guided transthoracic fine-needle aspiration biopsy of pulmonary lesions

    Energy Technology Data Exchange (ETDEWEB)

    Lima, Cristiano Dias de; Nunes, Rodolfo Acatauassu; Saito, Eduardo Haruo; Higa, Claudio; Cardona, Zanier Jose Fernando; Santos, Denise Barbosa dos, E-mail: cristianodiaslima@gmail.co [Hospital Universitario Pedro Ernesto (HUPE/UERJ), Rio de Janeiro, RJ (Brazil). Dept. Cirurgia Toracica

    2011-03-15

    Objective: to analyze the cytological findings of CT-guided percutaneous fine-needle aspiration biopsies of the lung, to demonstrate the diagnostic feasibility of the method in the investigation of pulmonary lesions, and to determine the complications of the procedure, evaluating its safety. Methods: a retrospective analysis of 89 patients with various types of pulmonary lesions who underwent 97 procedures over a period of five years. The patients were divided into groups regarding the indication for the procedure: suspicion of primary lung cancer (stages IIIB or IV); suspicion of lung cancer (stages I, II, or IIIA) and clinical contraindications for surgery; suspicion of pulmonary metastasis from other organs; and pulmonary lesions with benign radiological aspect. All of the procedures were performed with 25-gauge needles and were guided by spiral CT. The final diagnosis was confirmed by surgical biopsy and clinical/oncological follow-up. For the analysis of complications, the total number of procedures was considered. Results: the main indication for the procedure was suspicion of advanced stage primary lung cancer. The accuracy of the method for malignant lesions was 91.5%. The lesion was confirmed as cancer in 73% of the patients. The major complication was pneumothorax (27.8%), which required chest tube drainage in 12.4% of the procedures. Conclusions: the principal indication for CT-guided fine-needle biopsy was suspicion of primary lung cancer in patients who were not surgical candidates. The procedure has high diagnostic feasibility for malignant pulmonary diseases. The most prevalent complication was pneumothorax. However, in most cases, chest tube drainage was unnecessary. No deaths were related to the procedure. (author)

  17. A randomized, prospective cross-over trial comparing methylene blue-directed biopsy and conventional random biopsy for detecting intestinal metaplasia and dysplasia in Barrett's esophagus.

    Science.gov (United States)

    Ragunath, K; Krasner, N; Raman, V S; Haqqani, M T; Cheung, W Y

    2003-12-01

    The value of methylene blue-directed biopsies (MBDB) in detecting specialized intestinal metaplasia and dysplasia in Barrett's esophagus remains unclear. The aim of this study was to compare the accuracy of MBDB with random biopsy in detecting intestinal metaplasia and dysplasia in patients with Barrett's esophagus. A prospective, randomized, cross-over trial was undertaken to compare MBDB with random biopsy in patients with Barrett's esophagus segments 3 cm or more in length without macroscopic evidence of dysplasia or cancer. Dysplasia was graded as: indefinite for dysplasia, low-grade dysplasia, high-grade dysplasia, or carcinoma, and was reported in a blinded fashion. Fifty-seven patients were recruited, 44 of whom were male. A total of 1,269 biopsies were taken (MBDB-651, random biopsie-618). Analysis of the results by per-biopsy protocol showed that the MBDB technique diagnosed significantly more specialized intestinal metaplasia (75 %) compared to the random biopsy technique (68 %; P = 0.032). The sensitivity and specificity rates of MBDB for diagnosing specialized intestinal metaplasia were 91 % (95 % CI, 88 - 93 %) and 43 % (95 % CI, 36 - 51 %), respectively. The sensitivity and specificity rates of MBDB for diagnosing dysplasia or carcinoma were 49 % (95 % CI, 38 - 61 %) and 85 % (95 % CI, 82 - 88 %), respectively. There were no significant differences in the diagnosis of dysplasia and carcinoma - MBDB 12 %, random biopsy 10 %. The methylene blue staining pattern appeared to have an influence on the detection of specialized intestinal metaplasia and dysplasia/carcinoma. Dark blue staining was associated with increased detection of specialized intestinal metaplasia (P biopsies. Although MBDB prolongs the endoscopy procedure slightly, it is a safe and well-tolerated procedure. Further clinical studies on the MBDB technique exclusively in endoscopically normal dysplastic Barrett's esophagus are needed.

  18. Integrating machine learning and physician knowledge to improve the accuracy of breast biopsy.

    Science.gov (United States)

    Dutra, I; Nassif, H; Page, D; Shavlik, J; Strigel, R M; Wu, Y; Elezaby, M E; Burnside, E

    2011-01-01

    In this work we show that combining physician rules and machine learned rules may improve the performance of a classifier that predicts whether a breast cancer is missed on percutaneous, image-guided breast core needle biopsy (subsequently referred to as "breast core biopsy"). Specifically, we show how advice in the form of logical rules, derived by a sub-specialty, i.e. fellowship trained breast radiologists (subsequently referred to as "our physicians") can guide the search in an inductive logic programming system, and improve the performance of a learned classifier. Our dataset of 890 consecutive benign breast core biopsy results along with corresponding mammographic findings contains 94 cases that were deemed non-definitive by a multidisciplinary panel of physicians, from which 15 were upgraded to malignant disease at surgery. Our goal is to predict upgrade prospectively and avoid surgery in women who do not have breast cancer. Our results, some of which trended toward significance, show evidence that inductive logic programming may produce better results for this task than traditional propositional algorithms with default parameters. Moreover, we show that adding knowledge from our physicians into the learning process may improve the performance of the learned classifier trained only on data.

  19. CT-guided biopsy of pulmonary lesions : a comparison of diagnostic accuracy and complication rate between automated gun biopsy and fine needle aspiration biopsy

    International Nuclear Information System (INIS)

    Kim, Keon Woo; Kang, Duk Sik

    1998-01-01

    The purpose of this study is to compare the efficacy and safety of CT-guided automated gun biopsy with those of fine needle aspiration biopsy of pulmonary lesions. Under CT guidance, we performed automated gu biopsies in 115 cases of 109 patients and fine needle aspiration biopsies in 119 cases of 108 patients with pulmonary lesions. Between the two methods, we compared the diagnostic rate, diagnostic accuracy and frequency of compilations according to the depth and diameter of pulmonary lesions. The overall diagnostic rates of automated gun biopsy and fine needle aspiration biopsy were 76.5 % (88/115) and 64.7 % (77/119) respectively. There was a significant statistical difference (p=0.048), especially in the case of malignant lesions less than 3 cm (p=0.027) and more than 6 cm in maximal diameter (p=0.008), and in the lesions located from 1 cm to less than 3 cm from the pleural (p=0.030), as seen on CT. There was no significant statistical difference in the frequency of complications. Automated gun biopsy of pulmonary lesions under CT guidance is safe, with complications rate comparable to those of fine needle aspiration biopsy. A higher overall diagnostic rate can be achieved by automated gun biopsy than by fine needle aspiration biopsy. For the diagnosis of pulmonary lesions under CT guidance, automated gun biopsy is therefore a more useful procedure than fine needle aspiration biopsy. (author). 24 refs., 3 tabs

  20. The clinical application of percutaneous large core needle biopsy on large breast mass

    International Nuclear Information System (INIS)

    Peng Songhong; Ma Jie; Wang Guohong; Sun Guoping; Fu Jianmin; Zhou Dongxian

    2005-01-01

    Objective: An evaluation of the clinical application of percutaneous large core needle biopsy on large breast mass. Methods: Mammography and percutaneous large core needle biopsy were performed in 31 cases of large breast mass. Results: Apart from 5 cases showing characteristic calcification of malignancy, the rest cases were lack of diagnostic manifestation. Needle biopsy and pathological examination identified breast canner in 11 cases, suppurative mastitis in 9 case, fibrocystic mammary disorder in 7 cases, tuberculosis in 1 case, and fibroadenoma in 3 cases. Fibrocystic mammary disease was initially identified by biopsy in a case, while the following pathological diagnosis was fibrocystic mammary disorder with cancinoma in sim. Specificity rate of' biopsy was 96.8% and no false positive was observed. Vagotonia occurred in one case during the biopsy and hematoma in another. Conclusion: Percutaneous large core needle biopsy is a less invasive, simple, safe and reliable methods in the diagnosis of the large breast mass. And it may be recommended as a complementary procedure for routine imaging modality or surgical resection. (authors)

  1. US-guided biopsy of renal allografts using 18G biopsy gun: analysis of 200 cases

    International Nuclear Information System (INIS)

    Kim, Eun Kyung; Lee, Jong Tae; Kim, Myeong Jin; Yoo, Hyung Sik; Kim, Ki Whang; Park, Ki Ill; Chung, Hyun Joo

    1995-01-01

    We evaluated the effectiveness and safety of 18G biopsy gun with US guidance in the transplanted kidneys. We performed 200 US-guided percutaneous biopsies using 18G biopsy gun. Diagnostic efficacy and complication of the biopsy in these patients were analyzed. Biopsy specimens were adequate for histologic diagnoses in 193 patients(96.5%). The mean of the biopsy frequency was 3, the mean of total glomerular number was 21.64 and the mean glomerular number per one biopsy was 6.93. Major complications occurred in 3 (1.5%) of the 200 biopsies; hematuria developed in two patients, AV fistula in one. These complications were successfully controlled either by only transfusion or by coil embolization. There were no statistical differences in blood pressure, hemoglobin, BUN/Cr between pre-and post-renal biopsies. US-guided percutaneous biopsy of renal allograft with 18G biopsy gun is simple, safe, and accurate method in evaluating the renal allograft dysfunction

  2. Yield of abrams needle pleural biopsy in exudative pleural effusion

    International Nuclear Information System (INIS)

    Khan, I.N.; Zaman, M.; Khan, N.; Jadoon, H.; Ahmed, A.

    2009-01-01

    Pleural effusion is the abnormal collection of fluid in the pleural space resulting from excessive fluid production or decreased absorption and it is one of the most common clinical conditions that we come across in pulmonology clinics and in hospitals. The objective of prospective study was to evaluate the diagnostic role of Abrams Needle Biopsy in Exudative Pleural Effusion The study was performed at the Department of Pulmonology, Ayub Teaching Hospital, Abbottabad over a period of 1 year, i.e., January 2008 to December 2008. Sixty-three patients of either sex and all ages with exudative pleural effusion, on whom Abrams Needle Biopsy was performed were included in the study. Minimum of four specimens from each patient were taken and histopathology done. Out of 63 patients, histopathology revealed the cause in 60 (95%) cases. Tuberculosis, malignancy and rheumatoid pleurisy were confirmed in 34, 24, and 2 cases respectively. Specimens of 3 patients did not reveal any result and showed non-specific inflammation and were further investigated accordingly. The diagnostic yield of Biopsy was 95%. Pleural biopsy is still a reliable and valuable investigation in diagnosing pleural effusion, provided that adequate pleural specimen is taken. (author)

  3. Comb-push ultrasound shear elastography of breast masses: initial results show promise.

    Science.gov (United States)

    Denis, Max; Mehrmohammadi, Mohammad; Song, Pengfei; Meixner, Duane D; Fazzio, Robert T; Pruthi, Sandhya; Whaley, Dana H; Chen, Shigao; Fatemi, Mostafa; Alizad, Azra

    2015-01-01

    To evaluate the performance of Comb-push Ultrasound Shear Elastography (CUSE) for classification of breast masses. CUSE is an ultrasound-based quantitative two-dimensional shear wave elasticity imaging technique, which utilizes multiple laterally distributed acoustic radiation force (ARF) beams to simultaneously excite the tissue and induce shear waves. Female patients who were categorized as having suspicious breast masses underwent CUSE evaluations prior to biopsy. An elasticity estimate within the breast mass was obtained from the CUSE shear wave speed map. Elasticity estimates of various types of benign and malignant masses were compared with biopsy results. Fifty-four female patients with suspicious breast masses from our ongoing study are presented. Our cohort included 31 malignant and 23 benign breast masses. Our results indicate that the mean shear wave speed was significantly higher in malignant masses (6 ± 1.58 m/s) in comparison to benign masses (3.65 ± 1.36 m/s). Therefore, the stiffness of the mass quantified by the Young's modulus is significantly higher in malignant masses. According to the receiver operating characteristic curve (ROC), the optimal cut-off value of 83 kPa yields 87.10% sensitivity, 82.61% specificity, and 0.88 for the area under the curve (AUC). CUSE has the potential for clinical utility as a quantitative diagnostic imaging tool adjunct to B-mode ultrasound for differentiation of malignant and benign breast masses.

  4. Neuronavigator-guided cerebral biopsy.

    Science.gov (United States)

    Koivukangas, J; Louhisalmi, Y; Alakuijala, J; Oikarinen, J

    1993-01-01

    Neuronavigators are new dynamic interactive instruments that use on-line computers to orient imaging data to the surgical field and guide the neurosurgeon to his target. We have been working since 1987 on a neuronavigator that serves not only as a precise pointer, but also as a dynamic arm that can be used to hold instruments, such as biopsy guides. The neuronavigator arm consists of six joints with optical encoders and is attached to the Mayfield headholder. The arm is connected to a workstation running customized 3D image graphics software. Special instruments and surgical technique have been developed. Here, we report on early clinical experience with ten biopsy procedures: 4 low-grade and 3 high-grade astrocytomas, one craniopharyngioma and one chronic intracerebral haematoma and intracerebral cyst, both of the latter with surrounding tumour suspect tissue. In all glioma cases serial biopsies were taken from optimal sites under ultrasound imaging control. Eight cases showed representative tumour tissue, while in two cases neoplasia was ruled out. The neuronavigator proved to be versatile, allowing comprehensive imaging data to be adapted to the surgical field.

  5. Health-economic evaluation of magnetic resonance imaging before biopsy for diagnosis of prostate cancer; Gesundheitsoekonomische Evaluation einer Magnetresonanzbildgebung vor Biopsie zur Diagnose von Prostatakarzinomen

    Energy Technology Data Exchange (ETDEWEB)

    Stadlbauer, A.; Salomonowitz, E. [Landesklinikum St. Poelten (Austria). Zentrales Inst. fuer Radiologie, Diagnostik und Interventionelle Therapie; Bernt, R. [Hanusch Krankenhaus, Vienna (Austria). Zentralroentgeninst.; Plas, E. [Hanusch Krankenhaus, Vienna (Austria). Abt. fuer Urologie; Strunk, G. [Technische Univ. Dortmund (Germany). Wirtschaftswissenschaft und Oekonomische Bildung; Eberhardt, K. [Krankenhaus Schloss Werneck, Werneck (Germany). MRT-Kompetenzzentrum

    2011-10-15

    The aim of this study was the health-economic analysis of MR imaging in the diagnostics of suspicious prostate carcinoma (PCa) before execution of a first biopsy. The health-economic analysis included four steps: modeling, determination of probabilities, evaluation, and sensitivity analyses. We performed an effectiveness analysis from the patient perspective as well as a cost-effectiveness and a cost-utility analysis from the health insurance perspective for Austria and Germany. The effectiveness and cost-effectiveness analysis used a hypothetical cohort of 100 000 patients. The result parameters were number of biopsies, number of detected PCa, and monetary costs. For the cost-efficiency analysis, the result parameters, quality-adjusted life years (QALYs) and costs, were calculated for an individual patient. The efficiency analysis showed that MRI before a first biopsy can prevent ca. 64 000 unnecessary biopsies/ 100 000 patients. The diagnostic efficiency was higher by a factor of 1.7. Due to MRI, eight PCas were additionally detected. From a health insurance perspective, MRI was not cost-effective. Extra costs of ca. 42 m. Euro per 100 000 patients and of 650 Euro per prevented biopsy were calculated. The costs per detected PCa were increased by 1395 Euro. The attainable QALYs were a little higher for the MRI alternative, which was therefore not dominated. Our results do not permit a clear recommendation for or against the application of MRI in the diagnostics of PCa. From the patient perspective, it is to be endorsed due to the higher medical efficiency. However, it is connected with higher health insurance costs. (orig.)

  6. Dermatofibrosarcoma protuberans diagnosed by a single biopsy

    Directory of Open Access Journals (Sweden)

    Kristian Bakke Arvesen

    2012-07-01

    Full Text Available This brief report is about a 9 year old girl presenting with a 2.5 cm circular blue to violet discoloration on the anterolateral upper left thigh. The first biopsy taken revealed the diagnosis dermatofibrosarcoma protuberans. The patient underwent surgery at a specialized sarcoma center with post operative histology showing free wide resection margin. Preoperative chest x-ray showed no sign of metastasis. This brief report emphasizes the significance of the use of biopsy when cutaneous elements look suspicious and diagnosis is unclear.

  7. Effectiveness of core biopsy for screen-detected breast lesions under 10 mm: implications for surgical management.

    Science.gov (United States)

    Farshid, Gelareh; Downey, Peter; Pieterse, Steve; Gill, P Grantley

    2017-09-01

    Technical advances have improved the detection of small mammographic lesions. In the context of mammographic screening, accurate sampling of these lesions by percutaneous biopsy is crucial in limiting diagnostic surgical biopsies, many of which show benign results. Women undergoing core biopsy between January 1997 and December 2007 for core histology, 345 women (43.0%) were immediately cleared of malignancy and 300 (37.4%) were referred for definitive cancer treatment. A further 157 women (19.6%) required diagnostic surgical biopsy because of indefinite or inadequate core results or radiological-pathological discordance, and one woman (0.1%) needed further imaging in 12 months. The open biopsies were malignant in 46 (29.3%) cases. The positive predictive value of malignant core biopsy was 100%. The negative predictive value for benign core results was 97.7%, and the false-negative rate was 2.6%. The lesion could not be visualized after core biopsy in 5.1% of women and in 4.0% of women with malignant core biopsies excision specimens did not contain residual malignancy. Excessive delays in surgery because of complications of core biopsy were not reported. Even at this small size range, core biopsy evaluation of screen-detected breast lesions is highly effective and accurate. A lesion miss rate of 3.1% and under-representation of lesions on core samples highlight the continued need for multidisciplinary collaboration and selective use of diagnostic surgical biopsy. © 2015 Royal Australasian College of Surgeons.

  8. Prevalence of adult Pompe disease in patients with proximal myopathic syndrome and undiagnosed muscle biopsy.

    Science.gov (United States)

    Golsari, Amir; Nasimzadah, Arzoo; Thomalla, Götz; Keller, Sarah; Gerloff, Christian; Magnus, Tim

    2018-03-01

    We examined patients with limb-girdle muscle weakness and/or hyper-CKaemia and undiagnosed muscle biopsy for late onset Pompe disease (LOPD). Patients with an inconclusive limb-girdle muscle weakness who presented at our neuromuscular centre between 2005 and 2015 with undiagnosed muscle biopsies were examined by dry blood spot testing (DBS) including determination of the enzyme activity of acid alpha-glucosidase (GAA). In the case of depressed enzyme activity, additional gene testing of the GAA gene was carried out. Of the 340 evaluated muscle biopsies, 69 patients fulfilled the inclusion criteria and were examined with DBS. Among those patients, 76% showed a limb-girdle muscle weakness and 14% showed a hyper-CKaemia. A diagnosis of LOPD could be established in the case of two patients (2.9%) with reduced GAA enzyme activity and proof of mutations in the GAA gene. One of the two patients presents in the muscle biopsy suggestive features of Pompe disease including vacuoles with positive acid phosphatase reaction. In summary, our results show that a muscle biopsy can be helpful in identifying LOPD patients, but vacuolation with glycogen storage can also be absent. An inconspicuous muscle biopsy does not rule out Pompe disease. Consequently, all patients with limb-girdle muscle weakness should be examined by DBS before conducting a muscle biopsy. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Nail biopsy: A user's manual

    Directory of Open Access Journals (Sweden)

    Chander Grover

    2018-01-01

    Full Text Available Nail biopsy is a procedure not routinely resorted to; but when indicated, it is often the only clue left for diagnosis. At such times, it pays to be conversant with it. It is an investigation that not only provides etiologic, diagnostic, and prognostic information but also aids in understanding the pathogenesis of nail diseases. It can be of therapeutic value, especially with respect to nail tumors. This article compiles the procedural techniques for nail biopsy of various types and attempts to summarize the evidence available in the literature. The objective of nail biopsy is to clinch a precise diagnosis of nail pathology with a simple and safe surgical procedure, avoiding pain or permanent nail damage. Patient selection is of utmost importance, wherein, the patient does not have typical skin lesions, yields inadequate information on routine nail investigations, and has no peripheral vascular compromise. The patient needs to be explained about the risks associated, the expected functional handicap, the time required for regrowth, a possibility of permanent nail dystrophy, and a possibility of not achieving a diagnosis even after the biopsy. Techniques and types of various nail biopsies are being discussed in this article. The specimen could be collected as an excision biopsy, punch biopsy, shave biopsy, or longitudinal biopsy. The trick lies in choosing the appropriate area for biopsy. Various biopsy types discussed in this article include nail plate biopsy (easiest and least scarring; nail bed biopsy (elliptical excision or punch; nail matrix biopsy (elliptical excision, punch excision (≤3 mm or tangential/shave excision; and nail fold biopsy. Complications reported along with means to minimize them are also discussed.

  10. Multiple biopsy probe sampling enabled minimally invasive electrical impedance tomography

    International Nuclear Information System (INIS)

    Shini, Mohanad; Rubinsky, Boris

    2008-01-01

    Biopsies are a reliable method for examining tissues and organs inside the body, in particular for detection of tumors. However, a single biopsy produces only limited information on the site from which it is taken. Therefore, tumor detection now employs multiple biopsy samplings to examine larger volumes of tissue. Nevertheless, even with multiple biopsies, the information remains discrete, while the costs of biopsy increase. Here we propose and evaluate the feasibility of using minimally invasive medical imaging as a means to overcome the limitations of discrete biopsy sampling. The minimally invasive medical imaging technique employs the biopsy probe as electrodes for measurements of electrical impedance tomography relevant data during each biopsy sampling. The data from multiple samplings are combined and used to produce an EIT image of the tissue. Two- and three-dimensional mathematical simulations confirm that the minimally invasive medical imaging technique can produce electrical impedance tomography images of the tissues between the biopsy probe insertion sites. We show that these images can detect tumors that would be missed with multiple biopsy samplings only, and that the technique may facilitate the detection of tumors with fewer biopsies, thereby reducing the cost of cancer detection

  11. Transrectal ultrasound and needle biopsy of the prostate

    Directory of Open Access Journals (Sweden)

    Tomaž Smrkolj

    2016-01-01

    Full Text Available In the last 25 years widespread use of prostatic specific antigen caused a stage migration of prostate cancer towards localized disease at diagnosis, which resulted in transrectal ultrasound biopsy to become standard in clinical practice. Transrectal ultrasound examination of the prostate is used to diagnose benign prostatic diseases, e.g. benign prostatic enlargement, prostatitis, prostatic and seminal vesicle cysts. It is also important in detection of obstructive causes of male infertility. Transrectal ultrasound examination is performed most often in needle biopsy for prostate cancer diagnosis. Besides guiding systematic tissue core biopsy, characteristic ultrasound changes enables target biopsies of suspect areas. The article describes indications, contraindications, antibiotic prophylaxis, various biopsy templates and complications of the needle biopsy. Experience with transrectal ultrasound guided biopsy at Department of urology at University medical center in Ljubljana is presented.

  12. Ultrasound-Guided Fine-Needle Aspiration Biopsy of Multiple Thyroid Nodules

    International Nuclear Information System (INIS)

    Kim, Ji Dae; Bae, Il Hun; Lee, Seung Young; Han, Gi Seok; Cha, Sang Hun; Kim, Sung Jin; Park, Kil Sun; Koong, Sung Soo; Lee, Ok Jun

    2006-01-01

    To standardize the number of nodules which necessitates ultrasound-guided, fine-needle, aspiration biopsy in patients who have multiple thyroid nodules with the same sonographic characteristics as each other. From February, 2002 to March, 2004, among patients whose diagnosis was confirmed by ultrasound-guided, fine-needle, aspiration biopsy, 545 nodules of 203 patients were found in sonography with more than two thyroid nodules. Each thyroid gland nodule was classified on a score from 0 to 2 points on the basis of the following 5 characteristics: internal content, margin, echogenicity, shape and calcification in sonography. When the score of all characteristics was the same, by deciding on nodules with the same sonographic characteristics and with the score of at least one characteristic being different, we divided the nodules with different sonographic characteristics in a patient. By methods such as given in the preceding descriptions, patients with multiple thyroid nodules were separated into two groups: one in which all nodules had the same sonographic characteristics and another in which nodules have at least one different sonographic characteristic. Then, each pathologic result was searched for the same case and different case in each patient group. Among the 203 patients who were diagnosed with multiple thyroid nodules in ultrasonography, 79 patients (38.9%) had nodules with the same ultrasonographic characteristics and 124 patients (61.1%) had nodules with at least one different ultrasonographic characteristic. All 79 patient's nodules with the same ultrasonographic characteristics in each patient showed the same pathologic result in all cases (100.0%) and there was no case showing a different pathologic result. Otherwise, among the 124 patient's nodules with different ultrasonographic characteristics, each patient showed the same pathologic result in 111 (89.5%) and different pathologic result in 13 (10.5%). In patients who have multiple thyroid nodules

  13. Indications for diagnostic open biopsy of mammographic screen-detected lesions preoperatively diagnosed as fibroadenomas by needle biopsy and their outcomes

    International Nuclear Information System (INIS)

    Sala, M.A.; Dhillon, R.; Brookes, D.; Lagrange, C.; Metcalf, C.; Wylie, E.

    2015-01-01

    Aim: To identify the clinical, radiological, and histopathological factors that resulted in a diagnostic open biopsy of mammographic screen-detected lesions diagnosed preoperatively as fibroadenomas by needle biopsy. Materials and methods: BreastScreen WA data over 10 year period from 1 January 1999 to 31 December 2008 was reviewed. Results: Among the 760,027 women screened in Western Australia between 1999 and 2008, 31 had a fine-needle aspiration (FNA) or a core biopsy (CB) diagnosing a fibroadenoma and subsequently underwent a diagnostic open biopsy (DOB). Three were preoperatively diagnosed as fibroadenoma by initial FNA but subsequent CB showed that these were not fibroadenomas and, therefore, were excluded from the present series. Of the 28 cases, DOB identified 21 fibroadenomas, two cellular fibroadenomas, two benign phyllodes tumours, one malignant phyllodes tumour, one fibroadenoma containing ductal carcinoma in situ (DCIS), and one case of a 40 mm adenosis tumour with a small 5 mm fibroadenoma. The lesions ranged from 5–100 mm in size with an average size of 28 mm. DOB and CB results were concordant in 25 (89%) of the cases. The primary clinical indications for undergoing DOB included indeterminate histopathological findings of cellular fibroadenomas versus phyllodes tumour (n = 10), enlarging size (n = 4), large size (n = 5), fibroadenomas with atypia (n = 1), discordant radiological and pathological findings (n = 3), patient preference (n = 1), association with a second screen-detected lesion requiring excision (n = 2), and an unknown indication (n = 1). Conclusion: CB diagnosis of fibroadenomas is a safe diagnosis unless it has atypical clinical, radiological, or pathological features. - Highlights: • The aim was to identify factors that lead to excision of benign fibroadenomas. • Screen detected fibroadenomas must be adequately sampled to exclude malignancy. • Large, enlarging, cellular or atypical lesions should undergo

  14. Abdominal wall fat pad biopsy

    Science.gov (United States)

    Amyloidosis - abdominal wall fat pad biopsy; Abdominal wall biopsy; Biopsy - abdominal wall fat pad ... is the most common method of taking an abdominal wall fat pad biopsy . The health care provider cleans the ...

  15. Thyroid nodules with nondiagnostic results on repeat fine-needle aspiration biopsy: which nodules should be considered for repeat biopsy or surgery rather than follow-up?

    Energy Technology Data Exchange (ETDEWEB)

    Eun, Na Lae; Chang, Hang Seok; Gweon, Hye Mi; Kim, Jeong Ah; Youk, Ji Hyun; Son, Eun Jun [Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of); Yoo, Mi Ri [Dept. of Radiology, Dongjak Kyunghee Hospital, Seoul (Korea, Republic of); Park, Ah Young [Dept. of Radiology, Korea University Ansan Hospital, Korea University College of Medicine, Ansan (Korea, Republic of); Moon, Hee Jung [Dept. of Radiology and Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2016-07-15

    The goal of this study was to assess the clinicopathologic and ultrasonographic features of thyroid nodules with nondiagnostic results on repeat ultrasonography (US)-guided fineneedle aspiration biopsy (FNAB) according to size and the number of suspicious findings and to determine the proper management of nodules with consecutive nondiagnostic results. This retrospective study included 297 nodules with nondiagnostic results on repeat FNAB that were evaluated by US over the course of at least 12 months of follow-up, a follow-up biopsy, or an operation. We compared clinical and US variables between benign and malignant nodules in thyroid nodules with repeat nondiagnostic results. The comparison of benign and malignant nodules with repeat nondiagnostic results revealed that age, marked hypoechogenicity, irregular or microlobulated margins, microcalcifications, and nonparallel shape were significantly associated with malignancy. Multivariate logistic regression analysis in malignant nodules revealed that microcalcifications and irregular or microlobulated margins were independently associated with malignancy. Among them, only irregular or microlobulated margins were independently significant as a predictor of malignancy in repeatedly nondiagnostic nodules measuring >10 mm. Using receiver operating characteristic analysis, the best cutoff value for the “number of suspicious findings” between benign and malignant nodules was three in nodules of all sizes, three in nodules measuring ≤10 mm, and two in nodules measuring >10 mm. Irregular or microlobulated margins may be the most frequent US features in repeatedly nondiagnostic nodules >10 mm. The presence of “two or more suspicious findings” can be used as the cutoff for distinguishing benign and malignant nodules.

  16. Evaluating imaging-pathology concordance and discordance after ultrasound-guided breast biopsy

    Science.gov (United States)

    2018-01-01

    Ultrasound (US)-guided breast biopsy has become the main method for diagnosing breast pathology, and it has a high diagnostic accuracy, approaching that of open surgical biopsy. However, methods for confirming adequate lesion retrieval after US-guided biopsy are relatively limited and false-negative results are unavoidable. Determining imaging-pathology concordance after US-guided biopsy is essential for validating the biopsy result and providing appropriate management. In this review article, we briefly present the results of US-guided breast biopsy; describe general aspects to consider when establishing imaging-pathology concordance; and review the various categories of imaging-pathology correlations and corresponding management strategies. PMID:29169231

  17. Backscattering analysis of high frequency ultrasonic imaging for ultrasound-guided breast biopsy

    Science.gov (United States)

    Cummins, Thomas; Akiyama, Takahiro; Lee, Changyang; Martin, Sue E.; Shung, K. Kirk

    2017-03-01

    A new ultrasound-guided breast biopsy technique is proposed. The technique utilizes conventional ultrasound guidance coupled with a high frequency embedded ultrasound array located within the biopsy needle to improve the accuracy in breast cancer diagnosis.1 The array within the needle is intended to be used to detect micro- calcifications indicative of early breast cancers such as ductal carcinoma in situ (DCIS). Backscattering analysis has the potential to characterize tissues to improve localization of lesions. This paper describes initial results of the application of backscattering analysis of breast biopsy tissue specimens and shows the usefulness of high frequency ultrasound for the new biopsy related technique. Ultrasound echoes of ex-vivo breast biopsy tissue specimens were acquired by using a single-element transducer with a bandwidth from 41 MHz to 88 MHz utilizing a UBM methodology, and the backscattering coefficients were calculated. These values as well as B-mode image data were mapped in 2D and matched with each pathology image for the identification of tissue type for the comparison to the pathology images corresponding to each plane. Microcalcifications were significantly distinguished from normal tissue. Adenocarcinoma was also successfully differentiated from adipose tissue. These results indicate that backscattering analysis is able to quantitatively distinguish tissues into normal and abnormal, which should help radiologists locate abnormal areas during the proposed ultrasound-guided breast biopsy with high frequency ultrasound.

  18. Nerve Biopsy In The Diagnosis Of Leporsy

    OpenAIRE

    Hazra B; Banerjee P P; Bhattacharyya N K; Gupta P N; Barbhunia J N; Sanyal S

    1997-01-01

    Skin and nerve biopsies were done in 33 cases of different clinical types of leprosy selected from Dermatology OPD of Medical College and Hospitals, Calcutta during 1994-95. Histopathological results were compared with emphasis on the role of nerve biopsies in detection of patients with multibacillary leprosy. The evident possibility of having patients with multibacillary leprosy in peripheral leprosy with multiple drugs. It is found that skin and nerve biopsy are equally informative in borde...

  19. Full-thickness rectal biopsy in children suspicious for Hirschsprung's disease is safe and yields a low number of insufficient biopsies

    DEFF Research Database (Denmark)

    Bjørn, Niels; Rasmussen, Lars; Qvist, Niels

    2018-01-01

    INTRODUCTION: The diagnosis of Hirschsprung's disease (HD) relies on the histological demonstration of aganglionosis in the bowel wall. Biopsies may be obtained by rectal suction biopsy (RSB) or by transanal full-thickness excision biopsy (FTB). The objective of the present study was to evaluate...... the frequency of complications and inconclusive biopsies after FTB in children referred with suspicion of HD. The secondary objective was to calculate the frequency of proven aganglionosis. METHODS: A retrospective chart review was performed of all patients under the age of 16years who underwent transanal FTB...... during the time period of 2008-2014. RESULTS: A total of 555 patients were included in the review. Inconclusive biopsies were found at the primary biopsy in 35 patients (5.9%). Aganglionosis was found in 12% of the cases. The complication rate was 6.6% (39 patients), 85% of which were classified...

  20. Improved transvenous liver biopsy needle

    DEFF Research Database (Denmark)

    Henriksen, Jens Henrik Sahl; Matzen, P; Christoffersen, P

    1979-01-01

    A modified type of the standard transvenous cholangiography biopsy needle is described. The modified tranvenous liver biopsy needle caused only minimal artefactual changes of the liver biopsy specimens. The new type of biopsy needle is a modified Menghini needle. The conventional Menghini needle...... should be avoided for transvenous catheter biopsies because of risk of leaving catheter fragments in the liver....

  1. Nerve Biopsy In The Diagnosis Of Leporsy

    Directory of Open Access Journals (Sweden)

    Hazra B

    1997-01-01

    Full Text Available Skin and nerve biopsies were done in 33 cases of different clinical types of leprosy selected from Dermatology OPD of Medical College and Hospitals, Calcutta during 1994-95. Histopathological results were compared with emphasis on the role of nerve biopsies in detection of patients with multibacillary leprosy. The evident possibility of having patients with multibacillary leprosy in peripheral leprosy with multiple drugs. It is found that skin and nerve biopsy are equally informative in borderline and lepromatour leprosy and is the only means to diagnose polyneuritic leprosy. Nerve biopsy appears to be more informative in the diagnosis of all clinical types of leprosy.

  2. Analysis of the value of post-radiation prostate biopsy in predicting subsequent disease progression

    International Nuclear Information System (INIS)

    Benda, R.; Shamsa, F.; Meetze, K.; Bolton, S.; Littrup, P.; Grignon, D.; Washington, T.; Forman, J.D.

    1997-01-01

    Purpose: To analyze the value of Transrectal ultrasound(TRUS), Color flow doppler(CFD) and Prostate specific antigen(PSA) in identifying residual disease in the prostate status post external beam radiation therapy and to determine the value of this pathologic information in predicting subsequent disease progression. Materials and Methods: As part of four prospective protocols, 146 patients had scheduled TRUS guided prostate biopsies 6-25 months status post radiation therapy. The stage distribution was: 13% T1, 51% T2, and 36% T3/T4. Fifty six percent had neo-adjuvant hormones. Conformal photon or mixed neutron/photon irradiation was given to a median 2 Gy/fraction equivalent dose of 77 Gy(range 74 to 84 Gy). Following treatment, patients were assessed by digital rectal exam (DRE), PSA and TRUS guided biopsies at 6, 12 and/or 18 months. The ultrasound and CFD results were scored as normal, suspicious or abnormal. Sextant biopsies were obtained as well as ultrasound guided biopsies from any abnormal ultrasound or doppler area. The biopsies, all read by one pathologist (DG), were graded as negative, marked, moderate, minimal therapeutic effect or positive. The median followup post radiation therapy was 33.6 months and post biopsy was 25.3 months. Comparisons were done by Kappa index with corresponding 95% CI, chi square and Fisher's exact tests. Results: Twenty-eight patients had biopsies at both six and 12-18 months. Overall 35% of patients had all negative cores, 30% had at least one core showing a marked therapeutic effect, and 35% had at least one core showing moderate or minimal therapeutic effect or were positive. Although CFD correlated with a positive biopsy in 9% and a suspicious doppler identified cancer in 15% of cases, an abnormal TRUS identified cancer in 29.5% biopsies ((49(166))). However, a serum PSA >1.5ng/ml at the time of biopsy predicted 61% of positive biopsies ((23(38))). A negative biopsy was associated with low stage (≤T2c, p=0.001), low pre

  3. A randomized controlled trial of electrocoagulation-enabled biopsy versus conventional biopsy in the diagnosis of endobronchial lesions.

    Science.gov (United States)

    Khan, Ajmal; Aggarwal, Ashutosh N; Agarwal, Ritesh; Bal, Amanjit; Gupta, Dheeraj

    2011-01-01

    Although electrocoagulation at time of endobronchial biopsy can potentially reduce procedure-related bleeding during fiberoptic bronchoscopy (FOB), it can also impair quality of tissue specimen; credible data for either are lacking. To evaluate the impact of hot biopsy on the quality of tissue samples and to quantify the amount of procedure-related bleeding during endobronchial biopsy. In this single-center, prospective, single-blind, randomized controlled study we included adult patients referred for FOB and having endobronchial lesions. Patients were randomized to bronchial biopsy using an electrocoagulation-enabled biopsy forceps, with (EC+ group) or without (EC- group) application of electrocoagulation current (40 W for 10 s in a monopolar mode). Procedure-related bleeding was semi-quantified by observer description, as well as through a visual analogue scale. Overall quality of biopsy specimen and tissue damage were assessed and graded by a pulmonary pathologist blinded to FOB details. 160 patients were randomized to endobronchial biopsy with (n = 81) or without (n = 79) the application of electrocoagulation. There were no severe bleeding episodes in either group, and severity of bleeding in the EC+ and EC- groups was similar (median visual analogue scale scores of 14 and 16, respectively). Histopathological diagnosis was similar in the EC+ and EC- groups (77.8% and 82.3%, respectively). There was no significant difference in tissue quality between the two groups. Use of electrocoagulation-enabled endobronchial biopsy does not alter specimen quality and does not result in any significant reduction in procedure-related bleeding. Copyright © 2010 S. Karger AG, Basel.

  4. Histopathological analysis of gastric mucosal biopsies in non ulcer dyspepsia

    International Nuclear Information System (INIS)

    Sarfraz, T.; Hafeez, M.; Tariq, H.; Azhar, M.

    2016-01-01

    Objective: To find out the pattern of gastric mucosal histopathological findings in gastric biopsies of patients with non ulcer dyspepsia. Study Design: Prospective descriptive study. Place and Duration of Study: Histopathology department Combined Military Hospital (CMH) Kharian Pakistan from Jan to Dec 2015. Material and Methods: One hundred patients presenting at outpatient gastroenterology department with dyspepsia having no endoscopic lesion were included in the study. Two gastric mucosal biopsies from antrum and two from corpus were taken. The specimens were processed and examined histologically to see the changes. Results: Gastric biopsies of 100 patients including 65 males and 35 females presenting with non ulcer dyspepsia were studied. Most of the patients were between the age group of 31-50 years. Histological examination of gastric biopsies revealed 70 percent of patients having histological features of gastritis, while 30 percent having no significant histological finding. Chronic inflammation was seen in 70 cases (70 percent), activity in 15 cases (15 percent), glandular atrophy in 2 cases (2 percent) and intestinal metaplasia in 2 cases (2 percent). H.Pylori were identified in 25 cases (25 percent) based on haematoxylin and eosin (H and E) staining and modified giemsa staining. Conclusion: Most the cases of non ulcer dyspepsia show histological evidence of gastritis, however a significant number of patients showed no gastric mucosal histological abnormality. A significantly low frequency of H. Pylori in gastric biopsies noted in non ulcer dyspepsia cases may be due to more frequent use of antibiotics and acid suppressant drugs used by general practitioners at some stage of disease. (author)

  5. Psoriasis skin biopsy image segmentation using Deep Convolutional Neural Network.

    Science.gov (United States)

    Pal, Anabik; Garain, Utpal; Chandra, Aditi; Chatterjee, Raghunath; Senapati, Swapan

    2018-06-01

    Development of machine assisted tools for automatic analysis of psoriasis skin biopsy image plays an important role in clinical assistance. Development of automatic approach for accurate segmentation of psoriasis skin biopsy image is the initial prerequisite for developing such system. However, the complex cellular structure, presence of imaging artifacts, uneven staining variation make the task challenging. This paper presents a pioneering attempt for automatic segmentation of psoriasis skin biopsy images. Several deep neural architectures are tried for segmenting psoriasis skin biopsy images. Deep models are used for classifying the super-pixels generated by Simple Linear Iterative Clustering (SLIC) and the segmentation performance of these architectures is compared with the traditional hand-crafted feature based classifiers built on popularly used classifiers like K-Nearest Neighbor (KNN), Support Vector Machine (SVM) and Random Forest (RF). A U-shaped Fully Convolutional Neural Network (FCN) is also used in an end to end learning fashion where input is the original color image and the output is the segmentation class map for the skin layers. An annotated real psoriasis skin biopsy image data set of ninety (90) images is developed and used for this research. The segmentation performance is evaluated with two metrics namely, Jaccard's Coefficient (JC) and the Ratio of Correct Pixel Classification (RCPC) accuracy. The experimental results show that the CNN based approaches outperform the traditional hand-crafted feature based classification approaches. The present research shows that practical system can be developed for machine assisted analysis of psoriasis disease. Copyright © 2018 Elsevier B.V. All rights reserved.

  6. Protective Capnothorax During Transthoracic Needle Biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Kavanagh, John, E-mail: jokavana@tcd.ie; Siemienowicz, Miranda L.; Lyen, Stephen; Kandel, Sonja; Rogalla, Patrik [University of Toronto, Division of Cardiothoracic Imaging, Joint Department of Medical Imaging, University Health Network and Mount Sinai Hospital (Canada)

    2017-04-15

    PurposeTransthoracic needle biopsy (TTNB) is an established procedure in the management of pulmonary nodules. The most common complications are directly related to crossing the lung or visceral pleura during the biopsy. In this study, we describe the use of carbon dioxide instead of room air to create a protective “capnothorax” during TTNB.Materials and MethodsFive patients underwent creation of a capnothorax during TTNB. Parameters recorded were location and size of target, distance from pleura, length of procedure, volume of carbon dioxide, periprocedural complications and biopsy result.ResultsInduction of capnothorax was successful in all cases. In two patients, a continuous infusion of carbon dioxide was required to maintain an adequate volume of intrapleural gas. In two patients, the carbon dioxide resolved spontaneously and in the remaining patients it was aspirated at the end of the procedure. All biopsies were diagnostic with no periprocedural or postprocedural complications.ConclusionThis study suggests that protective iatrogenic capnothorax is a safe and effective technique during TTNB. The intrinsic properties and availability of carbon dioxide make it an attractive alternative to room air.

  7. Comb-push ultrasound shear elastography of breast masses: initial results show promise.

    Directory of Open Access Journals (Sweden)

    Max Denis

    Full Text Available To evaluate the performance of Comb-push Ultrasound Shear Elastography (CUSE for classification of breast masses.CUSE is an ultrasound-based quantitative two-dimensional shear wave elasticity imaging technique, which utilizes multiple laterally distributed acoustic radiation force (ARF beams to simultaneously excite the tissue and induce shear waves. Female patients who were categorized as having suspicious breast masses underwent CUSE evaluations prior to biopsy. An elasticity estimate within the breast mass was obtained from the CUSE shear wave speed map. Elasticity estimates of various types of benign and malignant masses were compared with biopsy results.Fifty-four female patients with suspicious breast masses from our ongoing study are presented. Our cohort included 31 malignant and 23 benign breast masses. Our results indicate that the mean shear wave speed was significantly higher in malignant masses (6 ± 1.58 m/s in comparison to benign masses (3.65 ± 1.36 m/s. Therefore, the stiffness of the mass quantified by the Young's modulus is significantly higher in malignant masses. According to the receiver operating characteristic curve (ROC, the optimal cut-off value of 83 kPa yields 87.10% sensitivity, 82.61% specificity, and 0.88 for the area under the curve (AUC.CUSE has the potential for clinical utility as a quantitative diagnostic imaging tool adjunct to B-mode ultrasound for differentiation of malignant and benign breast masses.

  8. Retrospective 5-year analysis of MR-guided biopsies in a low-field MR system

    International Nuclear Information System (INIS)

    Zangos, Stephan; Mueller, C.; Mayer, F.; Naguib, N.N.; Nour-Eldin, N.E.A.; Herzog, C.; Hammerstingl, R.M.; Thalhammer, A.; Mack, M.G.; Vogl, T.J.; Eichler, K.; Hansmann, M.L.

    2009-01-01

    Purpose: The purpose of this study was to evaluate the safety and clinical value of MR-guided biopsies in an open 0.2 T low-field system. Materials and methods: A total of 322 patients with suspicious lesions of different body regions were biopsied in a low-field MRI system (0.2 T, Concerto, Siemens). The procedures were guided using T1-weighted Flash sequences (TR/TE = 100/9; 70 ). The lesions were repeatedly biopsied using the coaxial technique with a 15-gauge (diameter 2 mm) puncture needle. Complications and biopsy findings were analyzed retrospectively. Results: In all cases the biopsy procedures were successfully performed with MR guidance. In 298 patients diagnosis was able to be confirmed on the basis of the probes. The clinical follow-up showed that in 24 patients the lesions were missed by MR-guided biopsy. From this a sensitivity of 86%, a specificity of 87% and an accuracy of 93% were calculated. In two patients major complications were observed (morbidity rate 0.6%). Conclusion: MR-guided biopsy can be performed safely and precisely in a low-field MR system and are a supplement to US or CT-guided biopsies. (orig.)

  9. Clinical application of Lin's biopsy grasper for intrauterine targeted biopsy and polypectomy during office hysteroscopy.

    Science.gov (United States)

    Cheng, Hsin-Yi; Lin, Bao-Liang; Tseng, Jen-Yu; Ueno, Kazunori; Nakada, Sakura

    2018-06-01

    Hysteroscopy has widely been used for diagnosis of the uterine cavity; however, target biopsy has often been difficult in part to the inherent limitations of ancillary instruments. Lin's biopsy grasper was specifically designed to work in conjunction with a flexible hysteroscope to obtain intrauterine biopsy under transabdominal sonography. Herein, we share our clinical experience in the management of endometrial abnormalities with the use of Lin's biopsy grasper during office-based hysteroscopy. From February 2006 to November 2016, the use of Lin's biopsy grasper for tissue biopsy was attempted on 126 cases. We retrospectively recorded and analyzed the patients' preoperative characteristics and biopsy outcomes to demonstrate the feasibility and efficacy of Lin's biopsy grasper. Out of the one hundred and twenty-six enrolled patients, satisfactory targeted biopsies were achieved; including high diagnostic rate (92.1%, with 116 cases confirmed histologically) and adequate tissue retrieval (77.8%, with 98 cases obtaining optimal specimen volume). All patients tolerated the procedure without analgesics or anesthesia. Diagnostic flexible hysteroscopy combined with the use of Lin's biopsy grasper has proven to be an effective tool for intrauterine evaluation and obtaining tissue sample. Copyright © 2018. Published by Elsevier B.V.

  10. [Comparative study of histological results between resection and biopsy of the prostate].

    Science.gov (United States)

    Mathieu, R; Tibari, Y; Verhoest, G; Vincendeau, S; Manunta, A; Rioux-Leclercq, N; Bensalah, K

    2014-05-01

    To evaluate the histological correlation between transuretral resection chips and biopsy cores within a population of patients who underwent resection of prostate (TURP) and prostate biopsies (BPx). Clinical and tumoral data of 77 patients who had both procedures simultaneously or with a slight delay were collected. According to the presence of prostate cancer (Pca), 4 groups were defined: group 1 (TURP and BPx negative), group 2 (TURP positive, BPx negative), group 3 (TURP negative, BPx positive), group 4 (TURP and BPx positive). Means and proportions were compared using Anova and χ(2) test, respectively. The patients were older in groups 3 and 4 (79 and 76 respectively, P=0.65). The PSA was higher in the groups 3 and 4 (64 and 55 ng/mL) than the groups 1 and 2 (10.6 et 16 respectively, P=0.23). The number of positive biopsy was higher in the group 4 than the group 3 (5.6 vs. 4.6, P<0.0001), the chips were more invaded in the group 4 than the group 2 (41% vs. 11% P<0.0001), the Gleason score at TURP was higher in the group 4 than the group 2 (7.5 vs. 6.2 P<0.0001). Our study underlines that the Pca of transition and peripheral zones seems to have distinct characteristics. When chips of TURP and BPx were both invaded, it was due to an aggressive cancer. The decision to explore the peripheral zone in the case of positive TURP must take clinical context into consideration. Copyright © 2013. Published by Elsevier Masson SAS.

  11. Is MR imaging useful for detecting prostate cancer in cases requiring repeat biopsy?. Presidential award proceedings

    International Nuclear Information System (INIS)

    Ito, Hirotoshi; Takahata, Akiko; Goto, Mariko; Masunami, Terutoshi; Yuen, Sachiko; Yamada, Kei; Nishimura, Tsunehiko

    2007-01-01

    The purpose of this study was to evaluate the usefulness of magnetic resonance (MR) imaging in detecting prostate cancer in cases requiring repeat biopsy. Twenty patients with negative first prostate biopsy were evaluated by T2-weighted images (T 2 W), diffusion weighted image (DWI), and contrast-enhanced dynamic MRI at 1.5T prior to repeat biopsy. Eleven of the 20 also underwent MR imaging before initial biopsy. Cancer criteria were defined as an area of low signal intensity on T 2 W, high signal intensity on DWI, and early enhancement on dynamic MR imaging. We compared MR imaging findings with biopsy results. Prostate cancer was detected by repeat biopsy in nine of 20 patients. MR imaging demonstrated the cancer lesion in seven of the 9 patients whose biopsies were positive for cancer. MR imaging of 5 patients whose biopsies showed cancer also demonstrated cancer lesion previous to initial biopsy. Most cancers were detected in the anterior, apex, and far lateral areas. False-negative cases were low-grade cancers and had a few positive biopsy cores. In patients with repeat prostate biopsy, prior MR imaging may be valuable for detecting and localizing prostate cancer. (author)

  12. Liver Biopsies for Chronic Hepatitis C: Should Nonultrasound-Guided Biopsies Be Abandoned?

    Directory of Open Access Journals (Sweden)

    Jennifer A Flemming

    2009-01-01

    Full Text Available BACKGROUND/OBJECTIVE: Liver biopsy has been the gold standard for grading and staging chronic hepatitis C virus (HCV-mediated liver injury. Traditionally, this has been performed by trained practitioners using a nonimage-guided percutaneous technique at the bedside. Recent literature suggests an expanding role for radiologists in obtaining biopsies using an ultrasound (US-guided technique. The present study was undertaken study to determine if the two techniques produced liver biopsy specimens of similar quality and hypothesized that at our institution, non-US-guided percutaneous liver biopsies for HCV would be of higher quality than US-guided specimens.

  13. CT-guided biopsies and drainage

    International Nuclear Information System (INIS)

    Scheppers, I.; Wollschlaeger, D.

    2011-01-01

    Following the implementation of computed tomography (CT) or ultrasound-guided biopsy of solid tumors and the puncture and drainage of liquid processes, the number of surgical open biopsies and curative operations for abscess drainage has declined. Such CT-guided interventions are performed in nearly every organ. Instead of aspiration biopsies, more and more core biopsies are being performed to allow histopathological evaluation and thus allowing targeted therapy. This article is intended to give a general overview of techniques, materials, indications and contraindications. Ultrasound-guided biopsies as well as large bore vacuum biopsies of the breast are not included in this review. (orig.) [de

  14. CT-guided needle biopsy of lung lesions: A survey of severe complication based on 9783 biopsies in Japan

    International Nuclear Information System (INIS)

    Tomiyama, Noriyuki; Yasuhara, Yoshifumi; Nakajima, Yasuo; Adachi, Shuji; Arai, Yasuaki; Kusumoto, Masahiko; Eguchi, Kenji; Kuriyama, Keiko; Sakai, Fumikazu; Noguchi, Masayuki; Murata, Kiyoshi; Murayama, Sadayuki; Mochizuki, Teruhito; Mori, Kiyoshi; Yamada, Kozo

    2006-01-01

    Purpose: The aim of our study was to update the rate of severe complications following CT-guided needle biopsy in Japan via a mailed survey. Materials and methods: Postal questionnaires regarding CT-guided needle biopsy were sent out to multiple hospitals in Japan. The questions regarded: the total number and duration of CT-guided lung biopsies performed at each hospital, and the complication rates and numbers of pneumothorax, hemothorax, air embolism, tumor seeding, tension pneumothorax and other rare complications. Each severe complication was followed with additional questions. Results: Data from 9783 biopsies was collected from 124 centers. Pneumothorax was the most common complication, and occurred in 2412 (35%) of 6881 cases. A total of 39 (35%) hospitals reported 74 (0.75%) cases with severe complications. There were six cases (0.061%) with air embolism, six cases (0.061%) with tumor seeding at the site of the biopsy route, 10 cases (0.10%) with tension pneumothorax, six cases (0.061%) with severe pulmonary hemorrhage or hemoptysis, nine cases (0.092%) with hemothorax, and 27 cases (0.26%) with others, including heart arrest, shock, and respiratory arrest. From a total of 62 patients with severe complications, 54 patients (0.55%) recovered without sequela, however one patient (0.01%) recovered with hemiplegia due to cerebral infarction, and the remaining seven patients (0.07%) died. Conclusions: This is the first national study documenting severe complications with respect to CT-guided needle biopsy in Japan. The complication rate in Japan is comparable to internationally published figures. We believe this data will improve both clinicians as well as patients understanding of the risk versus benefit of CT-guided needle biopsy, resulting better decisions

  15. Fast MRI-guided vacuum-assisted breast biopsy: initial experience.

    Science.gov (United States)

    Liberman, Laura; Morris, Elizabeth A; Dershaw, D David; Thornton, Cynthia M; Van Zee, Kimberly J; Tan, Lee K

    2003-11-01

    The purpose of this study was to evaluate a new method for performing MRI-guided vacuum-assisted breast biopsy in a study of lesions that had subsequent surgical excision. SUBJECTS AND METHODS. Twenty women scheduled for MRI-guided needle localization and surgical biopsy were prospectively entered in the study. MRI-guided biopsy was performed with a vacuum-assisted probe, followed by placement of a localizing clip, and then needle localization for surgical excision. Vacuum-assisted biopsy and surgical histology were correlated. Vacuum-assisted biopsy was successfully performed in 19 (95%) of the 20 women. The median size of 27 MRI-detected lesions that had biopsy was 1.0 cm (range, 0.4-6.4 cm). Cancer was present in eight (30%) of 27 lesions and in six (32%) of 19 women; among these eight cancers, five were infiltrating and three were ductal carcinoma in situ (DCIS). Among these 27 lesions, histology was benign at vacuum-assisted biopsy and at surgery in 19 (70%), cancer at vacuum-assisted biopsy in six (22%), atypical ductal hyperplasia at vacuum-assisted biopsy and DCIS at surgery in one (4%), and benign at vacuum-assisted biopsy with surgery showing microscopic DCIS that was occult at MRI in one (4%). The median time to perform vacuum-assisted biopsy of a single lesion was 35 min (mean, 35 min; range, 24-48 min). Placement of a localizing clip, attempted in 26 lesions, was successful in 25 (96%) of 26, and the clip was retrieved on specimen radiography in 22 (96%) of 23. One complication occurred: a hematoma that resolved with compression. MRI-guided vacuum-assisted biopsy is a fast, safe, and accurate alternative to surgical biopsy for breast lesions detected on MRI.

  16. SU-F-J-06: Optimized Patient Inclusion for NaF PET Response-Based Biopsies

    Energy Technology Data Exchange (ETDEWEB)

    Roth, A; Harmon, S; Perk, T; Jeraj, R [University of Wisconsin, Madison, WI (United States)

    2016-06-15

    Purpose: A method to guide mid-treatment biopsies using quantitative [F-18]NaF PET/CT response is being investigated in a clinical trial. This study aims to develop methodology to identify patients amenable to mid-treatment biopsy based on pre-treatment imaging characteristics. Methods: 35 metastatic prostate cancer patients had NaF PET/CT scans taken prior to the start of treatment and 9–12 weeks into treatment. For mid-treatment biopsy targeting, lesions must be at least 1.5 cm{sup 3} and located in a clinically feasible region (lumbar/sacral spine, pelvis, humerus, or femur). Three methods were developed based on number of lesions present prior to treatment: a feasibility-restricted method, a location-restricted method, and an unrestricted method. The feasibility restricted method only utilizes information from lesions meeting biopsy requirements in the pre-treatment scan. The unrestricted method accounts for all lesions present in the pre-treatment scan. For each method, optimized classification cutoffs for candidate patients were determined. Results: 13 of the 35 patients had enough lesions at the mid-treatment for biopsy candidacy. Of 1749 lesions identified in all 35 patients at mid-treatment, only 9.8% were amenable to biopsy. Optimizing the feasibility-restricted method required 4 lesions at pre-treatment meeting volume and region requirements for biopsy, resulting patient identification sensitivity of 0.8 and specificity of 0.7. Of 6 false positive patients, only one patient lacked lesions for biopsy. Restricting for location alone showed poor results (sensitivity 0.2 and specificity 0.3). The optimized unrestricted method required patients have at least 37 lesions in pretreatment scan, resulting in a sensitivity of 0.8 and specificity of 0.8. There were 5 false positives, only one lacked lesions for biopsy. Conclusion: Incorporating the overall pre-treatment number of NaF PET/CT identified lesions provided best prediction for identifying candidate

  17. SU-F-J-06: Optimized Patient Inclusion for NaF PET Response-Based Biopsies

    International Nuclear Information System (INIS)

    Roth, A; Harmon, S; Perk, T; Jeraj, R

    2016-01-01

    Purpose: A method to guide mid-treatment biopsies using quantitative [F-18]NaF PET/CT response is being investigated in a clinical trial. This study aims to develop methodology to identify patients amenable to mid-treatment biopsy based on pre-treatment imaging characteristics. Methods: 35 metastatic prostate cancer patients had NaF PET/CT scans taken prior to the start of treatment and 9–12 weeks into treatment. For mid-treatment biopsy targeting, lesions must be at least 1.5 cm 3 and located in a clinically feasible region (lumbar/sacral spine, pelvis, humerus, or femur). Three methods were developed based on number of lesions present prior to treatment: a feasibility-restricted method, a location-restricted method, and an unrestricted method. The feasibility restricted method only utilizes information from lesions meeting biopsy requirements in the pre-treatment scan. The unrestricted method accounts for all lesions present in the pre-treatment scan. For each method, optimized classification cutoffs for candidate patients were determined. Results: 13 of the 35 patients had enough lesions at the mid-treatment for biopsy candidacy. Of 1749 lesions identified in all 35 patients at mid-treatment, only 9.8% were amenable to biopsy. Optimizing the feasibility-restricted method required 4 lesions at pre-treatment meeting volume and region requirements for biopsy, resulting patient identification sensitivity of 0.8 and specificity of 0.7. Of 6 false positive patients, only one patient lacked lesions for biopsy. Restricting for location alone showed poor results (sensitivity 0.2 and specificity 0.3). The optimized unrestricted method required patients have at least 37 lesions in pretreatment scan, resulting in a sensitivity of 0.8 and specificity of 0.8. There were 5 false positives, only one lacked lesions for biopsy. Conclusion: Incorporating the overall pre-treatment number of NaF PET/CT identified lesions provided best prediction for identifying candidate patients

  18. Gallium-67 imaging in patients with dilated cardiomyopathy and biopsy-proven myocarditis

    International Nuclear Information System (INIS)

    O'Connell, J.B.; Henkin, R.E.; Robinson, J.A.; Subramanian, R.; Scanlon, P.J.; Gunnar, R.M.

    1984-01-01

    Current standards for detection of myocarditis in a clinical setting rely on endomyocardial biopsy for accurate diagnosis. With this technique a subset of patients with dilated cardiomyopathy show unsuspected myocarditis histologically. Endomyocardial biopsy, despite its specificity, may lack sensitivity due to sampling error if the inflammation is patchy or focal. Therefore, inflammation-sensitive radioisotopic imaging may be a useful adjunct in the diagnosis of myocarditis. This study was designed to evaluate the applicability of gallium-67 (67Ga) myocardial imaging as an adjunct to endomyocardial biopsy in the diagnosis of myocarditis. Sixty-eight consecutive patients referred for evaluation of dilated cardiomyopathy underwent 71 parallel studies with 67Ga imaging and biopsies that served as the basis of comparison for this study. Histologic myocarditis was identified in 8% of biopsy specimens. Clinical and hemodynamic parameters could not be used to predict the presence of myocarditis. Five of six biopsy samples (87%) with myocarditis showed dense 67Ga uptake, whereas only nine of 65 negative biopsy samples (14%) were paired with equivocally positive 67Ga scans. The single patient with myocarditis and no myocardial 67Ga uptake had dense mediastinal lymph node uptake that may have obscured cardiac uptake. The incidence of myocarditis on biopsy with a positive 67Ga scan was 36% (5/14); however, the incidence of myocarditis with a negative 67Ga scan was only 1.8% (1/57). Follow-up scans for three patients showed close correlation of 67Ga uptake with myocarditis on biopsy. In conclusion 67Ga may be a useful screening test for identifying patients with a high yield of myocarditis on biopsy, and serial scans may eliminate the need for frequent biopsies in patients with proven myocarditis

  19. Transrectal ultrasound-guided biopsy sepsis and the rise in carbapenem antibiotic use.

    Science.gov (United States)

    Leahy, Olivia R; O'Reilly, Mary; Dyer, David R; Phillips, David; Grummet, Jeremy P

    2015-12-01

    This study sought to determine the number of hospital admissions for sepsis following transrectal ultrasound-guided (TRUS) biopsy, and the rate of both prophylactic and therapeutic use of carbapenem antibiotics for TRUS biopsy, at a single institution. A retrospective review of prospectively collected data from the medical records electronic database of Cabrini Health, a private metropolitan hospital, was queried for coding of admissions under any admitting urologist for sepsis and prostate-related infections from 2009 to 2012. Records were examined for whether a TRUS biopsy had been performed within 14 days prior and if a therapeutic carbapenem was required. The database also queried the use of carbapenems as prophylaxis in patients undergoing TRUS biopsy. Of the 63 admissions for TRUS biopsy sepsis, multi-drug-resistant organisms were isolated from 26 (41%). Twenty-three admissions were from the 1937 patients who underwent a TRUS biopsy at Cabrini (a sepsis rate of 1.2%) and 40 were following TRUS biopsies at other centres. Thirty-seven (58.7%) patients received therapeutic carbapenems either empirically, or after culture results. Of the 1937 Cabrini TRUS biopsy patients, 154 (8%) were given a carbapenem as prophylaxis, with a rapid increase in prophylactic use over the 4 years studied from 0.25% to 13%. This study did not show evidence of an increasing rate of hospital admissions for TRUS biopsy sepsis at this institution. However, there was a dramatic uptake in prophylactic administration of carbapenems. Increasing carbapenem use may contribute to development of carbapenem-resistant bacteria. Alternative methods of prostate biopsy that avoid sepsis should be considered. © 2014 Royal Australasian College of Surgeons.

  20. [Gene expression analyses of kidney biopsies: the European renal cDNA bank--Kröner-Fresenius biopsy bank].

    Science.gov (United States)

    Cohen, C D; Kretzler, M

    2009-03-01

    Histological analysis of kidney biopsies is an essential part of our current diagnostic workup of patients with renal disease. Besides the already established diagnostic tools, new methods allow extensive analysis of the sample tissue's gene expression. Using results from a European multicenter study on gene expression analysis of renal biopsies, in this review we demonstrate that this novel approach not only expands the scope of so-called basic research but also might supplement future biopsy diagnostics. The goals are improved diagnosis and more specific therapy choice and prognosis estimates.

  1. Salivary gland biopsy

    Science.gov (United States)

    ... also be performed to diagnose diseases such as Sjogren syndrome . How to Prepare for the Test There is ... few days after the biopsy. The biopsy for Sjogren syndrome requires an injection of the anesthetic in the ...

  2. Percutaneous biopsy of non-palpable breast lesions with the advanced breast biopsy instrumentation (ABBI): analysis of indication strategies

    International Nuclear Information System (INIS)

    Wedegaertner, U.; Otto, U.; Buitrago-Tellez, C.; Bremerich, J.; Bongartz, G.; Oertli, D.; Torhorst, J.

    2001-01-01

    Purpose: To compare the indications for biopsy with and without the use of the Breast Imaging Reporting and Data System. Material and methods: Biopsies using the ABBI were performed in 62 patients with 64 non-palpable evident mammographic lesions. The initial decision for biopsy was made by non-radiologists due to suspicious microcalcifications (n=53) and masses (n=11). The indication was retrospectively reassessed by adopting the BI-RADS classification by three radiologists in consensus. The positive predictive value (PPV) of both indication strategies was assessed and compared. Results: Biopsies adopting ABBI were performed without major side-effects and were diagnostic. Carcinoma was present in 14 lesions: nine specimens were diagnosed as DCIS and five as invasive carcinomas. For the 50 benign lesions histology revealed mastopathies (26/50) and fibroadenomas (8/50) as the most frequent diagnosis. The positive predictive value (PPV) for the initial indication was 22%, whereas PPV for BI-RADS based indications (categories 4 and 5) was 31%. Conclusion: ABBI enables stereotactically-guided procedures that result in representative and diagnostic biopsies. Standardized criteria like BI-RADS improve the PPV and should be a mandatory part of mammographic evaluation. Radiologists should remain involved in the decision making. (orig.) [de

  3. Ultrasound-guided fine needle aspiration versus core needle biopsy: comparison of post-biopsy hematoma rates and risk factors.

    Science.gov (United States)

    Chae, In Hye; Kim, Eun-Kyung; Moon, Hee Jung; Yoon, Jung Hyun; Park, Vivian Y; Kwak, Jin Young

    2017-07-01

    To compare post-biopsy hematoma rates between ultrasound guided-fine needle aspiration and ultrasound guided-core needle biopsy, and to investigate risk factors for post-biopsy hematoma. A total of 5304 thyroid nodules which underwent ultrasound guided biopsy were included in this retrospective study. We compared clinical and US features between patients with and without post-biopsy hematoma. Associations between these features and post-biopsy hematoma were analyzed. Post-biopsy hematoma rate was 0.8% (43/5121) for ultrasound guided-fine needle aspiration and 4.9% (9/183) for ultrasound guided-core needle biopsy (P core needle biopsy (9/179, 5.0%) than with ultrasound guided-fine needle aspiration (9/1138, 0.8%) (P core needle biopsy was the only significant risk factor for post-biopsy hematoma (adjusted Odds Ratio, 6.458, P core needle biopsy than in ultrasound guided-fine needle aspiration and ultrasound guided-core needle biopsy was the only independent factor of post-biopsy hematoma in thyroid nodules.

  4. The future perspectives in transrectal prostate ultrasound guided biopsy

    Directory of Open Access Journals (Sweden)

    Sung Il Hwang

    2014-12-01

    Full Text Available Prostate cancer is one of the most common neoplasms in men. Transrectal ultrasound (TRUS-guided systematic biopsy has a crucial role in the diagnosis of prostate cancer. However, it shows limited value with gray-scale ultrasound alone because only a small number of malignancies are visible on TRUS. Recently, new emerging technologies in TRUS-guided prostate biopsy were introduced and showed high potential in the diagnosis of prostate cancer. High echogenicity of ultrasound contrast agent reflect the increased status of angiogenesis in tumor. Molecular imaging for targeting specific biomarker can be also used using ultrasound contrast agent for detecting angiogenesis or surface biomarker of prostate cancer. The combination of TRUS-guided prostate biopsy and ultrasound contrast agents can increase the accuracy of prostate cancer diagnosis. Elastography is an emerging ultrasound technique that can provide the information regarding tissue elasticity and stiffness. Tumors are usually stiffer than the surrounding soft tissue. In two types of elastography techniques, shearwave elastography has many potential in that it can provide quantitative information on tissue elasticity. Multiparametric magnetic resonance imaging (MRI from high resolution morphologic and functional magnetic resonance (MR technique enables to detect more prostate cancers. The combination of functional techniques including apparent diffusion coefficient map from diffusion weighted imaging, dynamic contrast enhanced MR and MR spectroscopy are helpful in the localization of the prostate cancer. MR-ultrasound (US fusion image can enhance the advantages of both two modalities. With MR-US fusion image, targeted biopsy of suspicious areas on MRI is possible and fusion image guided biopsy can provide improved detection rate. In conclusion, with recent advances in multiparametric-MRI, and introduction of new US techniques such as contrast-enhanced US and elastography, TRUS-guided biopsy

  5. Effects of percutaneous needle liver biopsy on dairy cow behaviour

    DEFF Research Database (Denmark)

    Mølgaard, Lene; Damgaard, Birthe Marie; Bjerre-Harpøth, Vibeke

    2012-01-01

    In cattle, percutaneous needle liver biopsy is used for scientific examination of liver metabolism. The impact of the biopsy procedure is, however, poorly investigated. Our aim was to examine the behaviour of dairy cows during and after liver biopsy. Data were collected from 18 dry cows....... Percutaneous needle liver biopsies (after administration of local anaesthesia (2% Procaine)) and blood samples were taken during restraining. During the control treatment, animals were restrained and blood sampled. During the biopsy procedure, cows showed increased restlessness (P = 0.008), frequency of head...... behavioural changes for up to 19 h – and particularly for behaviour previously associated with pain. Even though the exact welfare impact of percutaneous needle liver biopsies in cows is not known, and the magnitude of the behavioural changes was limited, pain always has negative effects on animal welfare...

  6. Percutaneous biopsy of non-palpable breast lesions with the advanced breast biopsy instrumentation (ABBI): analysis of indication strategies; Perkutane stereotaktische Biopsie nicht palpabler Mammalaesionen mit dem Advanced Breast Biopsy Instrumentation (ABBI) System: kritische Evaluation der Indikationsstellung

    Energy Technology Data Exchange (ETDEWEB)

    Wedegaertner, U.; Otto, U.; Buitrago-Tellez, C.; Bremerich, J.; Bongartz, G. [Basel Univ. (Switzerland). Inst. fuer Diagnostische Radiologie; Oertli, D. [Basel Univ. (Switzerland). Inst. fuer Chirurgie; Torhorst, J. [Basel Univ. (Switzerland). Inst. fuer Pathologie

    2001-03-01

    Purpose: To compare the indications for biopsy with and without the use of the Breast Imaging Reporting and Data System. Material and methods: Biopsies using the ABBI were performed in 62 patients with 64 non-palpable evident mammographic lesions. The initial decision for biopsy was made by non-radiologists due to suspicious microcalcifications (n=53) and masses (n=11). The indication was retrospectively reassessed by adopting the BI-RADS classification by three radiologists in consensus. The positive predictive value (PPV) of both indication strategies was assessed and compared. Results: Biopsies adopting ABBI were performed without major side-effects and were diagnostic. Carcinoma was present in 14 lesions: nine specimens were diagnosed as DCIS and five as invasive carcinomas. For the 50 benign lesions histology revealed mastopathies (26/50) and fibroadenomas (8/50) as the most frequent diagnosis. The positive predictive value (PPV) for the initial indication was 22%, whereas PPV for BI-RADS based indications (categories 4 and 5) was 31%. Conclusion: ABBI enables stereotactically-guided procedures that result in representative and diagnostic biopsies. Standardized criteria like BI-RADS improve the PPV and should be a mandatory part of mammographic evaluation. Radiologists should remain involved in the decision making. (orig.) [German] Ziel: Perkutane stereotaktische Biopsien mit dem ABBI stellen eine neue Alternative in der Abklaerung nicht palpabler Mammalaesionen dar. Es soll die Indikationsstellung mit und ohne Anwendung des Breast Imaging Reporting and Data System (BI-RADS) analysiert werden. Material und Methoden: Insgesamt wurde bei 62 Patientinnen mit 64 Laesionen eine Biopsie mit dem ABBI System durchgefuehrt. Die primaere Indikation zur ABBI Biopsie wurde von Nicht-Radiologen aufgrund von Mikrokalzifikationen in 53 Faellen und einer unklaren Verdichtung in 11 Faellen gestellt. Zusaetzlich erfolgte eine retrospektive Indikationsstellung der biopsierten

  7. Seminal epithelium in prostate biopsy can mimic malignant and premalignant prostatic lesions.

    Science.gov (United States)

    Arista-Nasr, J; Trolle-Silva, A; Aguilar-Ayala, E; Martínez-Benítez, B

    2016-01-01

    In most prostate biopsies, the seminal epithelium is easily recognised because it meets characteristic histological criteria. However, some biopsies can mimic malignant or premalignant prostatic lesions. The aims of this study were to analyse the histological appearance of the biopsies that mimic adenocarcinomas or preneoplastic prostatic lesions, discuss the differential diagnosis and determine the frequency of seminal epithelia in prostate biopsies. We consecutively reviewed 500 prostate puncture biopsies obtained using the sextant method and selected those cases in which we observed seminal vesicle or ejaculatory duct epithelium. In the biopsies in which the seminal epithelium resembled malignant or premalignant lesions, immunohistochemical studies were conducted that included prostate-specific antigen and MUC6. The most important clinical data were recorded. Thirty-six (7.2%) biopsies showed seminal epithelium, and 7 of them (1.4%) resembled various prostate lesions, including high-grade prostatic intraepithelial neoplasia, atypical acinar proliferations, adenocarcinomas with papillary patterns and poorly differentiated carcinoma. The seminal epithelium resembled prostate lesions when the lipofuscin deposit, the perinuclear vacuoles or the nuclear pseudoinclusions were inconspicuous or missing. Five of the 7 biopsies showed mild to moderate cellular atypia with small and hyperchromatic nuclei, and only 2 showed cellular pleomorphism. The patients were alive and asymptomatic after an average of 6 years of progression. The seminal epithelium resembles prostatic intraepithelial neoplasia, atypical acinar proliferations and various types of prostatic adenocarcinomas in approximately 1.4% of prostate biopsies. Copyright © 2015 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  8. [When to ask for a skin biopsy in a patient with leg ulcer? Retrospective study of 143 consecutive biopsies].

    Science.gov (United States)

    Stansal, A; Khayat, K; Duchatelle, V; Tella, E; Gautier, V; Sfeir, D; Attal, R; Lazareth, I; Priollet, P

    2018-02-01

    A vascular cause is found in around 85% of leg ulcer patients, but non-vascular causes are also observed. Their diagnosis is based on a set of clinical arguments and skin biopsy with histological analysis. The aim of this study was to analyze the results of these biopsies and to find common criteria for ulcers whose skin biopsies had led to the diagnosis of a non-vascular ulcer. A retrospective study was carried out on the analysis of 143 skin biopsies of leg ulcers. The reasons for the biopsy were mainly atypical clinical signs and/or the lack of improvement in care after 6 months, as advocated by the French health authorities. The skin biopsies led to a diagnosis of non-vascular ulcer in 4.9% of cases (7/143), including skin cancer (n=5, 3.5%), cutaneous leishmaniasis (n=1, 0.7%) and Pyoderma gangrenosum (n=1, 0.7%). The univariate statistical analysis revealed that an elevated rim and abnormal excessive granulation tissue were significantly more frequently found in these ulcers. All patients with a positive skin biopsy had associated vascular involvement. This study found a 5% rate of non-vascular causes of ulcers, mainly skin cancer. Elevated rims and abnormal excessive granulation tissue were the unusual features most commonly found in these ulcers. All patients whose skin biopsy revealed a non-vascular cause had associated vascular involvement. This information confirms the need to perform a skin biopsy, even in the presence of a vascular disease. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  9. Fatal mediastinal biopsy: How interventional radiology saves the day

    Directory of Open Access Journals (Sweden)

    Y Yaacob

    2012-01-01

    Full Text Available This was a case of a 35-year-old man with mediastinal mass requiring computed tomography (CT-guided biopsy for tissue diagnosis. A posterior approach with an 18-gauge biopsy needle was used to obtain tissue sample. Post biopsy, patient condition deteriorated and multiphase CT study detected active bleeding in arterial phase at the biopsy site with massive hemothorax. Subsequent angiography showed arterial bleeder arising from the apical branch of the right pulmonary artery. Selective endovascular embolization with NBCA (n-Butyl cyanoacrylate was successful. Patient survived the complication. The case highlighted a rare complication in a common radiology procedure and the value of the interventional radiology unit in avoiding a fatal outcome.

  10. Corpus vitreum, retina og chorioidea biopsi

    DEFF Research Database (Denmark)

    Scherfig, Erik Christian Høegh

    2002-01-01

    oftalmology, biopsy, choroid, corpus vitreum, retina, malignant melanoma, biopsy technic, retinoblastoma......oftalmology, biopsy, choroid, corpus vitreum, retina, malignant melanoma, biopsy technic, retinoblastoma...

  11. Diagnosis of prostate cancer with needle biopsy: should all cases be biopsied before treatment?

    Science.gov (United States)

    Oranusi, C K; Ugezu, A I; Nwofor, Ame

    2012-01-01

    The triad of digital rectal examination (DRE), serum prostate specific antigen, and transrectal ultrasound-guided prostate biopsy is used in the detection of prostate cancer (PCa). It is recommended that all cases of PCa should be diagnosed with needle biopsy before treatment. The exclusion criteria for those that may not be suitable have not yet been defined. We reviewed all the patients diagnosed with PCa at the Nnamdi Azikiwe University Teaching Hospital Nnewi, Southeast, Nigeria, from January 2007 to December 2010. Relevant biodata and method of diagnosis of PCa before treatment were reviewed. A total of 133 patients had bilateral orchidectomy over the period. 120 (90.2%) had their diagnosis confirmed by needle biopsy before bilateral orchidectomy (category 1), while 13 (9.8%) had bilateral orchidectomy before diagnosis was confirmed. The method of diagnosis for category 1 patients was with lower urinary tract symptoms (LUTS), abnormal DRE findings, elevated prostate-specific antigen (PSA), and transrectal needle biopsy. For category 11 patients, diagnosis of PCa was suspected based on LUTS, abnormal DRE findings, and elevated PSA. Of this number, 11 (84.6%) had, in addition, sudden onset paraplegia at presentation, while 2 (15.4%) had severe uncontrolled hematuria at presentation. All the patients in both categories had needle biopsy confirmation of their disease. The sensitivity of PSA was 99.2%. Needle biopsy of the prostate is the preferred method for the diagnosis of PCa in most cases before treatment is undertaken. There are valid reasons why all PCas will not be diagnosed in this fashion. Elevated PSA when combined with an abnormal DRE finding increases the predictive value for cancer. In areas where pathologists are lacking, abnormal DRE and elevated PSA results can be a guide to proceed to treatment especially, where there is severe compromise of patients' quality of life due to symptoms of advanced PCa while awaiting confirmation.

  12. Stereotaxic core needle biopsy of breast microcalcifications obtained using a standard mammography table with an add-on unit

    International Nuclear Information System (INIS)

    Ward, S.E.; Taves, D.H.; McCurdy, L.I.

    2000-01-01

    To demonstrate the reliability of stereotaxic biopsy of indeterminate microcalcifications using a standard mammography table with an add-on unit. In 121 cases of indeterminate microcalcifications, core biopsy was performed using a standard mammography table with an add-on stereotaxic unit. Microcalcifications were identified on radiography of core specimens. Microcalcifications and a definitive histologic diagnosis were obtained in 112 core biopsies (92.6%), with no significant complications. In 23 lesions frank malignancy was diagnosed, and all of these diagnoses were confirmed on surgery. Pathologic examination suggested carcinoma in 4 lesions, and open biopsy confirmed malignancy in 3 of these cases. Four lesions showed atypical ductal hyperplasia. Benign disease was diagnosed in 81 lesions, of which 78 remained stable on mammographic follow-up (mean 16 months later) and 3 were subjected to surgical biopsy (of which 1 was malignant and 2 were benign). Nine cases were technically unsatisfactory because microcalcifications were not sampled. Stereotaxic core biopsy performed with an add-on unit is a safe and reliable technique for biopsy of indeterminate microcalcifications. For successful biopsy, microcalcifications must be harvested. Pathologic results should be correlated with mammographic findings. The accuracy rate compares favourably with results reported using prone biopsy tables. In an era of cost containment, this alternative to prone biopsy tables could result m significant savings in terms of capital investment and use of hospital rooms. In this study, surgical biopsy could have been avoided in 64.5% of cases. (author)

  13. Biopsy - Multiple Languages

    Science.gov (United States)

    ... Biopsy - العربية (Arabic) Bilingual PDF Health Information Translations Breast Biopsy - العربية (Arabic) Bilingual PDF Health Information Translations Colposcopy - العربية (Arabic) Bilingual PDF ...

  14. Percutaneous needle-biopsy of the adrenal glands

    International Nuclear Information System (INIS)

    Wernecke, K.; Galanski, M.

    1986-01-01

    This account of techniques, range of indications and results of percutaneous adrenal biopsy refers to communications in the literature and to the authors' own experience. Lateral, transhepatic aspiration of adrenal material guided by sonographic control is more easy in the right adrenal gland. Punctation of the left adrenal gland ought to be done from the back and guided by computerized tomography, also in order to leave spleen, kidney, pancreas and stomach as unaffected as possible. The most frequent problem indicating adrenal biopsy still is differentiation between metastases or encretorily non-active adenomas in tumor patients. Experienced examiners will achieve an 80 to 90% sensitivity of adrenal biopsy. Clinically established, suspected phaeochromocytoma is an absolute contra-indication to fine-needle biopsy. (orig./MG) [de

  15. Unguided bronchoscopic biopsy: Does yield increase with operator experience

    Directory of Open Access Journals (Sweden)

    Tyagi Rahul

    2017-08-01

    Full Text Available Background Bronchoscopic Forceps biopsy (Endobronchial Biopsy (EBB and Trans Bronchial Lung Biopsy (TBLB are commonly performed for diagnosis in patients with endobronchial abnormalities or diffuse parenchymal involvement. As the operator gains experience his yield of various diagnostic bronchoscopic biopsies is expected to increase, however, no studies on the subject are available in literature. Aims To determine the effect of on- job experience on the yield of unguided bronchoscopic biopsies. Methods A total of 244 bronchoscopies were performed between Oct 2013 and Oct 2016. A retrospective analysis of all these bronchoscopies was undertaken. All patients who underwent biopsy were included in the study. Patients were divided into two groups with first group (Group A comprising of biopsies done between Oct 2013 to Apr 2015 and second group comprising biopsies done between May 2015 to Oct 2016 (Group B. The diagnostic yield in two groups was compared. Results Total 71 bronchoscopic biopsies were performed during Oct 2013 to Oct 2016. 36 patients were included in group A and 35 patients were included in group B. The groups were matched in demographic profile, clinical diagnosis, bronchoscopic findings and type of biopsy undertaken. The biopsy was diagnostic in 31 patient (43.6 per cent and nondiagnostic in 33 patients (46.4 per cent. There were 15 diagnostic biopsies in group A and 16 diagnostic biopsies in group B. The difference in the diagnostic biopsies between the two groups was not significant. Conclusion There was no significant impact of on job experience on diagnostic yield of biopsies. This may be due to adequate exposure during training leading to a diagnostic plateau being reached.

  16. Ultrasound-guided biopsy of greater omentum: An effective method to trace the origin of unclear ascites

    Energy Technology Data Exchange (ETDEWEB)

    Que Yanhong [Department of Ultrasound, First Affiliated Hospital of China Medical University, Shenyang, Liaoning 110001 (China)], E-mail: quebaobao@yahoo.com.cn; Wang Xuemei [Department of Ultrasound, First Affiliated Hospital of China Medical University, Shenyang, Liaoning 110001 (China)], E-mail: wxmlmt@yahoo.com.cn; Liu Yanjun [Department of Ultrasound, First Affiliated Hospital of China Medical University, Shenyang, Liaoning 110001 (China)], E-mail: lyj7512@sina.com; Li Ping [Department of Ultrasound, First Affiliated Hospital of China Medical University, Shenyang, Liaoning 110001 (China)], E-mail: liping7213@sina.com; Ou Guocheng [Department of Ultrasound, First Affiliated Hospital of China Medical University, Shenyang, Liaoning 110001 (China)], E-mail: yang9951@126.com; Zhao Wenjing [Department of Ultrasound, First Affiliated Hospital of China Medical University, Shenyang, Liaoning 110001 (China)], E-mail: awk999@163.com

    2009-05-15

    Objectives: Thickened greater omentum is encountered with high frequency in patients with ascites. The purpose of our study was to assess the utility of greater omentum biopsy under the guidance of ultrasound (US) in tracing the origin of unclear ascites and differentiating benign and malignant ascites. Materials and methods: We retrospectively reviewed our institutional database for all records of greater omentum biopsy cases. One hundred and ninety-four patients with unclear ascites and thickened greater omentum were included in the study. The sonograms of greater omentum were evaluated before undergoing the ultrasound-guided biopsy and a biopsy was considered successful if a specific benign or malignant diagnosis was rendered by the pathologist. Results: Successful biopsy was rendered for 182 biopsy procedures (93.8%, 182/194) including tuberculosis (n = 114), chronic inflammation (n = 3), metastases (n = 58), malignant mesothelioma (n = 6) and pseudomyxoma peritonei (n = 1). Twelve biopsies were non-diagnostic. According to the results of biopsy and follow-up, the sensitivity and specificity of biopsy in distinguishing malignant ascites from benign ascities were respectively 95.6% (65/68) and 92.9% (117/126). The greater omentum of 84 cases of tuberculous peritonitis showed 'cerebral fissure' sign and was well seen as an omental cake infiltrated with irregular nodules when involved by carcinomatosis. No 'cerebral fissure' sign was observed in peritoneal carcinomatosis. The sensitivity and specificity of this sign in indicating the existence of tuberculous peritonitis were 73.5% (89/121) and 100% (73/73). Moreover, if the specific 'cerebral fissure' sign was combined with the biopsy results, the specificity of biopsy in distinguishing malignant ascites from benign ascits increased to 96.8% (122/126). Conclusion: Ultrasound-guided biopsy of greater omentum is an important and effective method to diagnose the unclear ascites for

  17. Transvenous liver biopsy via the femoral vein

    International Nuclear Information System (INIS)

    Khosa, F.; McNulty, J.G.; Hickey, N.; O'Brien, P.; Tobin, A.; Noonan, N.; Ryan, B.; Keeling, P.W.N.; Kelleher, D.P.; McDonald, G.S.A.

    2003-01-01

    AIM: To study the safety, effectiveness and diagnostic value of transvenous forceps biopsy of the liver in 54 patients with coagulopathy, gross ascites or morbid obesity and suspected liver disease in whom percutaneous liver biopsy was contraindicated. MATERIAL AND METHODS: Forceps biopsy of the liver via the femoral vein was attempted in 54 adult patients with advanced liver disease of unknown aetiology who had coagulation disorders (41 cases), gross ascites (11 cases) or morbid obesity (two cases). In each patient two to six biopsies (average four) were taken using a radial jaw forceps inserted via the right or left femoral vein. RESULTS: The procedure was successful in 53 cases. Hepatic vein catheterization failed in one patient. Adequate liver tissue for diagnosis was obtained in 84% of cases. One patient developed delayed haemorrhage at 12 h from a capsular leak that was undetected during the biopsy procedure. This patient required blood transfusions and laparotomy to control bleeding. There were no deaths in the 53 patients studied. Transient minor chest and shoulder pain was encountered during sheath insertion into a hepatic vein in 23 patients. Three patients developed a femoral vein haematoma, which resolved with conservative treatment. CONCLUSION: Transvenous liver biopsy via the femoral vein is another safe, effective, simple alternative technique of biopsy when the percutaneous route is contraindicated

  18. Ultrasound-guided percutaneous renal biopsy with an automated biopsy gun in diffuse renal disease

    International Nuclear Information System (INIS)

    Kim, Ji Yang; Moon, Jeoung Mi; Park, Ji Hyun; Kwon, Jae Soo; Song, Ik Hoon; Kim, Sung Rok

    1994-01-01

    We evaluated the effectiveness and clinical usefulness of percutaneous renal biopsy by using automated biopsy gun under the real-time ultrasonographic guidance that was performed in 17 patients with diffuse renal disease. We retrospectively analysed the histopathological diagnosis and the patients' status after percutaneous renal biopsy.Adequate amount of tissue for the histologic diagnosis could be obtained in al patients. Histopathologic diagnosis included the minimal change nephrotic syndrome in 6 patients, the membrano proliferative glomerulonephritis in 4,the membranous glomerulonephritis in 2, the glomerulosclerosis in 2, Ig A nephropathy in 2, and the normal finding in 1. Significant complication occurred in only one patient who developed a transient loss of sensation at and around the biopsy site. In conclusion, automated biopsy gun was a very useful device in performing percutaneous biopsy for diffuse renal disease with a high success rate and a low complication rate

  19. Cryobiopsy: Should This Be Used in Place of Endobronchial Forceps Biopsies?

    Directory of Open Access Journals (Sweden)

    Edmundo R. Rubio

    2013-01-01

    Full Text Available Forceps biopsies of airway lesions have variable yields. The yield increases when combining techniques in order to collect more material. With the use of cryotherapy probes (cryobiopsy larger specimens can be obtained, resulting in an increase in the diagnostic yield. However, the utility and safety of cryobiopsy with all types of lesions, including flat mucosal lesions, is not established. Aims. Demonstrate the utility/safety of cryobiopsy versus forceps biopsy to sample exophytic and flat airway lesions. Settings and Design. Teaching hospital-based retrospective analysis. Methods. Retrospective analysis of patients undergoing cryobiopsies (singly or combined with forceps biopsies from August 2008 through August 2010. Statistical Analysis. Wilcoxon signed-rank test. Results. The comparative analysis of 22 patients with cryobiopsy and forceps biopsy of the same lesion showed the mean volumes of material obtained with cryobiopsy were significantly larger (0.696 cm3 versus 0.0373 cm3, P=0.0014. Of 31 cryobiopsies performed, one had minor bleeding. Cryopbiopsy allowed sampling of exophytic and flat lesions that were located centrally or distally. Cryobiopsies were shown to be safe, free of artifact, and provided a diagnostic yield of 96.77%. Conclusions. Cryobiopsy allows safe sampling of exophytic and flat airway lesions, with larger specimens, excellent tissue preservation and high diagnostic accuracy.

  20. Transbronchial biopsies safely diagnose amyloid lung disease

    Science.gov (United States)

    Govender, Praveen; Keyes, Colleen M.; Hankinson, Elizabeth A.; O’Hara, Carl J.; Sanchorawala, Vaishali; Berk, John L.

    2018-01-01

    Background Autopsy identifies lung involvement in 58–92% of patients with the most prevalent forms of systemic amyloidoses. In the absence of lung biopsies, amyloid lung disease often goes unrecognized. Report of a death following transbronchial biopsies in a patient with systemic amyloidosis cautioned against the procedure in this patient cohort. We reviewed our experience with transbronchial biopsies in patients with amyloidosis to determine the safety and utility of bronchoscopic lung biopsies. Methods We identified patients referred to the Amyloidosis Center at Boston Medical Center with lung amyloidosis diagnosed by transbronchial lung biopsies (TBBX). Amyloid typing was determined by immunohistochemistry or mass spectrometry. Standard end organ assessments, including pulmonary function test (PFT) and chest tomography (CT) imaging, and extra-thoracic biopsies established the extent of disease. Results Twenty-five (21.7%) of 115 patients with lung amyloidosis were diagnosed by TBBX. PFT classified 33.3% with restrictive physiology, 28.6% with obstructive disease, and 9.5% mixed physiology; 9.5% exhibited isolated diffusion defects while 19% had normal pulmonary testing. Two view chest or CT imaging identified focal opacities in 52% of cases and diffuse interstitial disease in 48%. Amyloid type and disease extent included 68% systemic AL disease, 16% localized (lung limited) AL disease, 12% ATTR disease, and 4% AA amyloidosis. Fluoroscopy was not used during biopsy. No procedure complications were reported. Conclusions Our case series of 25 patients supports the use of bronchoscopic transbronchial biopsies for diagnosis of parenchymal lung amyloidosis. Normal PFTs do not rule out the histologic presence of amyloid lung disease. PMID:28393574

  1. Variables affecting the risk of pneumothorax and intrapulmonal hemorrhage in CT-guided transthoracic biopsy

    International Nuclear Information System (INIS)

    Khan, M.F.; Straub, R.; Moghaddam, S.R.; Maataoui, A.; Gurung, J.; Thalhammer, A.; Vogl, T.J.; Jacobi, V.; Wagner, T.O.F.; Ackermann, H.

    2008-01-01

    The influence of various variables on the rate of pneumothorax and intrapulmonal hemorrhage associated with computed tomography (CT)-guided transthoracic needle biopsy of the lung were evaluated retrospectivly. One hundred and thirty-three patients underwent CT guided biopsy of a pulmonary lesion. Two patients were biopsied twice. Variables analyzed were lesion size, lesion location, number of pleural needle passes, lesion margin, length of intrapulmonal biopsy path and puncture time. Eighteen-gauge (18G) cutting needles (Trucut, Somatex, Teltow, Germany) were used for biopsy. Pneumothorax occured in 23 of 135 biopsies (17%). Chest tube placement was required in three out of 23 cases of pneumothorax (2% of all biopsies). Pneumothorax rate was significantly higher when the lesions were located in the lung parenchyma compared with locations at the pleura or chest wall (P < 0.05), but all pneumothorax cases which required chest tube treatment occured in lesions located less than 2 cm from the pleura. Longer puncture time led to an increase in pneumothorax rate (P < 0.05). Thirty-seven (27%) out of 135 biopsies showed perifocal hemorrhage. Intrapulmonal biopsy paths longer than 4 cm showed significantly higher numbers of perifocal hemorrhage and pneumothorax (P < 0.05). Significantly more hemorrhage occured when the pleura was penetrated twice during the puncture (P < 0.05). Lesion size <4 cm is strongly correlated with higher occurence of perifocal hemorrhage (P < 0.05). Lesion margination showed no significant effect on complication rate. CT-guided biopsy of smaller lesions correlates with a higher bleeding rate. Puncture time should be minimized to reduce pneumothorax rate. Passing the pleura twice significantly increases the risk of hemorrhage. Intrapulmonal biopsy paths longer than 4 cm showed significantly higher numbers of perifocal hemorrhage as well as pneumothorax. (orig.)

  2. Vacuum-assisted biopsies under MR guidance: results of 72 procedures

    Energy Technology Data Exchange (ETDEWEB)

    Malhaire, C.; El Khoury, C.; Thibault, F.; Athanasiou, A.; Petrow, P.; Ollivier, L.; Tardivon, A. [Institut Curie, Radiology Department, Paris (France)

    2010-07-15

    To investigate the clinical accuracy of magnetic resonance imaging-guided breast vacuum-assisted biopsy (MR-VAB). Of 97 scheduled MR-VAB for single MRI lesions (negative second-look sonography) categorised as BI-RADS 4 or 5, 4 were cancelled (undetected lesion = 2, technical problems = 2). Twenty-one patients lost to follow-up were excluded. Twenty-three patients (median age 51 years) were at high risk (BRCA1 = 11, BRCA2 = 7, familial risk = 5), 23 had a suspected local recurrence of breast cancer. Seventy-two imaged lesions (focus = 1, mass enhancement = 32, non-mass-like enhancement = 39) were targeted with a 10-gauge VAB probe using MRI guidance, with a median of 18 specimens per lesion (median procedural time 72 min, range 50-131 min) followed by clip placement. In the case of benignity, MRI follow-up was performed (19 patients, median 389 days, range 33-1,592) or mammography (3 patients, median 420 days, range 372-1,354). According to histopathology results, 29 lesions were benign, 10 were high-risk (papillary = 2, radial scar = 1, atypical epithelial hyperplasia = 7) and 33 malignant (ductal carcinoma in situ = 8, invasive cancers = 25). Three false negative results and 3 complications occurred (1 malaise, 1 skin defect, 1 infection). MRI-guided VAB represents an accurate tool for the histological diagnosis of lesions visible only at MRI. (orig.)

  3. Enzyme immunoassay of oestrogen receptors in needle biopsies from human liver

    DEFF Research Database (Denmark)

    Becker, U; Andersen, J; Poulsen, H S

    1991-01-01

    For quantitative assessments of sex hormone receptors in liver tissue, ligand binding assays are inconvenient, as they require large biopsies (0.5-1.0 g). The present study shows that it is possible to measure oestrogen receptors (ER) quantitatively in needle biopsy specimens as small as 10 mg...... by modifications of a commercial enzyme immunoassay employing monoclonal antibodies. Sucrose gradient centrifugation and the dextran charcoal method served as reference methods. A consecutive series of needle biopsies from patients suspected of liver disease were investigated. The biopsies (n = 37) had a median...

  4. Evaluation of lymphocytic exudative pleural effusion with pleural biopsy

    International Nuclear Information System (INIS)

    Khurram, M.; Jaffery, A.H.; Khar, Hamama-tul-Bushra; Malik, M.F.; Javed, S.; Burki, U.F.; Khan, B.A.; Ali, A.

    2002-01-01

    Objective: Evaluation of lymphocytic exudative pleural effusion by histopathological examination of pleural biopsy in patients with suspected tuberculous or malignant pleural effusion. Place and Duration of Study: The study was conducted at Pulmonology Department, Pakistan Institute of Medical Sciences, Islamabad and DHQ Teaching Hospital, Rawalpindi for two years 1999-2000. Subjects and Methods: A total of 120 patients with exudative pleural effusion underwent closed pleural biopsy with Abram's needle in standard way. Average 4 biopsy specimens were obtained in each patient which were examined histopathologically. Patients in whom a definite diagnosis was not possible were further investigated with repeat pleural biopsy, sputum examinations, bronchoscopy etc. Results definite histopathological diagnosis with pleural biopsy was possible in 59 (49.16% patients, including 13 diagnosed on repeat pleural biopsy. Two commonest diagnoses made were tuberculosis and adenocarcinoma, 64.40% and 13.55% respectively. Conclusion: Histopathological evaluation of pleural biopsy specimens can lead to diagnosis in 49.16% patients with exudative lymphocytic pleural effusion. (author)

  5. Usefulness of US-guided automated gun biopsy of nonpalpable breast lesions

    Energy Technology Data Exchange (ETDEWEB)

    Kwak, Min Sook; Kim, Hak Soo; Lee, Han Kyung; Koh, Sung Hye; O, Eun Young; Yoon, Myung Hwan; Yang, Dal Mo; Kim, Hyung Sik [Chungang Gil Hospital, Incheon (Korea, Republic of)

    1997-11-01

    To evaluate the clinical usefulness of ultrasonography(US)-guided automated gun biopsy of nonpalpable breast lesions. In 30 nonpalpable breast lesions over 0.6cm and detected on US, we performed US-guided biopsy using an 18-gauge automated biopsy gun. Two to four specimens were obtained from each lesion. We analyzed the site, size and depth of the lesions, and the length and histopathologic results of the specimens. In four lesions, surgical biopsy and gun biopsy results were compared. In 29 of 30 lesions(96.7%), specimens were adequate for histopathologic diagnosis, and this was as follows : one case of infiltrating ductal carcinoma, 13 of fibrocystic disease, 10 of fibrocystic disease versus fibroadenoma and one of fibrodenoma. There was also one reactive hyperplasia of LN, and one fatty one and two normal tissues, and in these four lesions, agreement between gun and surgical biopsy results was 100%. The only complication was minor bleeding, which was controlled by compression. US-guided automated gun biopsy is a clinically useful and safe procedure for evaluating nonpalpable breast lesions detected on US.

  6. Usefulness of US-guided automated gun biopsy of nonpalpable breast lesions

    International Nuclear Information System (INIS)

    Kwak, Min Sook; Kim, Hak Soo; Lee, Han Kyung; Koh, Sung Hye; O, Eun Young; Yoon, Myung Hwan; Yang, Dal Mo; Kim, Hyung Sik

    1997-01-01

    To evaluate the clinical usefulness of ultrasonography(US)-guided automated gun biopsy of nonpalpable breast lesions. In 30 nonpalpable breast lesions over 0.6cm and detected on US, we performed US-guided biopsy using an 18-gauge automated biopsy gun. Two to four specimens were obtained from each lesion. We analyzed the site, size and depth of the lesions, and the length and histopathologic results of the specimens. In four lesions, surgical biopsy and gun biopsy results were compared. In 29 of 30 lesions(96.7%), specimens were adequate for histopathologic diagnosis, and this was as follows : one case of infiltrating ductal carcinoma, 13 of fibrocystic disease, 10 of fibrocystic disease versus fibroadenoma and one of fibrodenoma. There was also one reactive hyperplasia of LN, and one fatty one and two normal tissues, and in these four lesions, agreement between gun and surgical biopsy results was 100%. The only complication was minor bleeding, which was controlled by compression. US-guided automated gun biopsy is a clinically useful and safe procedure for evaluating nonpalpable breast lesions detected on US

  7. Biopsy Needle Localization and Tracking Using ROI-RK Method

    Directory of Open Access Journals (Sweden)

    Yue Zhao

    2014-01-01

    Full Text Available ROI-RK method is a biopsy needle localization and tracking method. Previous research work has proved that it has a robust performance on different series of simulated 3D US volumes. Unfortunately, in real situations, because of the strong speckle noise of the ultrasound image and the different echogenic properties of the tissues, the real 3D US volumes have more complex background than the simulated images used previously. In this paper, to adapt the ROI-RK method in real 3D US volumes, a line-filter enhancement calculation only in the ROI is added to increase the contrast between the needle and background tissue, decreasing the phenomenon of expansion of the biopsy needle due to reverberation of ultrasound in the needle. To make the ROI-RK method more stable, a self-correction system is also implemented. Real data have been acquired on an ex vivo heart of lamb. The result of the ROI-RK method shows that it is capable to localize and track the biopsy needle in real situations, and it satisfies the demand of real-time application.

  8. Can concurrent core biopsy and fine needle aspiration biopsy improve the false negative rate of sonographically detectable breast lesions?

    Directory of Open Access Journals (Sweden)

    Chang Tsai-Wang

    2010-07-01

    Full Text Available Abstract Background The aims of this study were to determine the accuracy of concurrent core needle biopsy (CNB and fine needle aspiration biopsy (FNAB for breast lesions and to estimate the false-negative rate using the two methods combined. Methods Over a seven-year period, 2053 patients with sonographically detectable breast lesions underwent concurrent ultrasound-guided CNB and FNAB. The sonographic and histopathological findings were classified into four categories: benign, indeterminate, suspicious, and malignant. The histopathological findings were compared with the definitive excision pathology results. Patients with benign core biopsies underwent a detailed review to determine the false-negative rate. The correlations between the ultrasonography, FNAB, and CNB were determined. Results Eight hundred eighty patients were diagnosed with malignant disease, and of these, 23 (2.5% diagnoses were found to be false-negative after core biopsy. After an intensive review of discordant FNAB results, the final false-negative rate was reduced to 1.1% (p-value = 0.025. The kappa coefficients for correlations between methods were 0.304 (p-value p-value p-value Conclusions Concurrent CNB and FNAB under ultrasound guidance can provide accurate preoperative diagnosis of breast lesions and provide important information for appropriate treatment. Identification of discordant results using careful radiological-histopathological correlation can reduce the false-negative rate.

  9. Medical audit of rectal biopsy diagnosis of inflammatory bowel disease.

    Science.gov (United States)

    Frei, J V; Morson, B C

    1982-03-01

    The records of the rectal biopsy diagnoses of ulcerative colitis and Crohn's disease in the Department of Pathology, St Mark's Hospital, London, were reviewed. The biopsy diagnoses were compared to subsequent resection diagnoses on the same patients, and annual and seasonal variations in the frequency of these and related diagnoses were studied. The accuracy rate for the biopsy diagnosis of ulcerative colitis was about 70% and for Crohn's disease about 40% each time a biopsy was read. The low figure for the accuracy rate for Crohn's disease could be attributed to sampling error inherent in the diagnosis of a disease which is essentially patchy, showing discontinuous pathology. Also, many patients with Crohn's disease have a normal rectum which is biopsied to demonstrate the distinction from ulcerative colitis. In practical terms therefore a 40% accuracy rate in Crohn's disease is probably adequate. The rate of "false-positive" diagnoses was about 5%. There was a seasonal variation in the frequency of these two diagnoses, but no variation attributable to changes in observers, as pathology trainees in the Department change regularly. The frequency of diagnoses of non-specific inflammation and of normal colon did show such non-random variations.

  10. Aspiration biopsy of testis: another method for histologic examination

    International Nuclear Information System (INIS)

    Nseyo, U.O.; Englander, L.S.; Huben, R.P.; Pontes, J.E.

    1984-01-01

    The most important method for evaluating the pathogenesis of male infertility is open testicular biopsy. Herein the authors describe a method of aspiration biopsy of testis for histologic examination. Sexually mature dogs and rats treated with chemotherapeutic agents and ionizing radiation were followed with periodic testicular aspiration biopsy during and after treatment. The histologic findings from the aspiration biopsy compare with the results of routine histologic examination in assessing spermatogenetic activity and delineating pathologic changes. The puncture in the experimental animals was performed under general anesthesia. In human patients testicular biopsy could be done under local anesthesia in an outpatient clinic. The procedure would be less painful, minimally invasive, and more cost-effective

  11. Sonographically-guided vacuum-assisted biopsy with digital mammography-guided skin marking of suspicious breast microcalcifications: comparison of outcomes with stereotactic biopsy in Asian women.

    Science.gov (United States)

    Hahn, Soo Yeon; Shin, Jung Hee; Han, Boo-Kyung; Ko, Eun Young

    2011-02-01

    Management of suspicious microcalcifications in very thin breasts is problematic. To evaluate whether sonographically-guided vacuum-assisted biopsy (USVAB) with digital mammography-guided skin marking (DM) for the diagnosis of breast microcalcifications is comparable to stereotactic-guided vacuum-assisted biopsy (SVAB) in Asian women with thin breasts. Retrospective review was performed for 263 consecutive suspicious microcalcification lesions in 261 women who underwent USVAB with DM or SVAB using a prone table between January 2004 and December 2007. SVAB was performed for 190 lesions and USVAB for 73 lesions. Biopsy results were correlated with surgical pathology or followed up for at least 12 months. The diagnostic outcomes of SVAB and USVAB to diagnose microcalcifications were compared. Of 263 lesions, 104 (40%) underwent surgery and 159 (60%) were followed up. SVAB and USVAB groups showed similar final categories or the extent of microcalcifications. US visible lesions were 57 (78%) of 73 at USVAB and 14 (10%) of 140 at SVAB. Of 57 US visible lesions at USVAB, 29 (51%) were not found in initial US but were detectable with the help of DM. Specimen radiographs were negative in 2.1% of lesions at SVAB and in 4.1% at USVAB (p=0.4008). The under-estimation rate and false-negative rate were similar in SVAB and USVAB. US with DM facilitates US visibility of microcalcifications. USVAB with DM can produce acceptable biopsy results, as can SVAB, to diagnose breast microcalcifications in patients with thin breasts.

  12. CT-Guided Biopsy of Small Liver Lesions: Visibility, Artifacts, and Corresponding Diagnostic Accuracy

    International Nuclear Information System (INIS)

    Stattaus, Joerg; Kuehl, Hilmar; Ladd, Susanne; Schroeder, Tobias; Antoch, Gerald; Baba, Hideo A.; Barkhausen, Joerg; Forsting, Michael

    2007-01-01

    Purpose. Our study aimed to determine the visibility of small liver lesions during CT-guided biopsy and to assess the influence of lesion visibility on biopsy results. Material and Methods. Fifty patients underwent CT-guided core biopsy of small focal liver lesions (maximum diameter, 3 cm); 38 biopsies were performed using noncontrast CT, and the remaining 12 were contrast-enhanced. Visibility of all lesions was graded on a 4-point-scale (0 = not visible, 1 = poorly visible, 2 = sufficiently visible, 3 = excellently visible) before and during biopsy (with the needle placed adjacent to and within the target lesion). Results. Forty-three biopsies (86%) yielded diagnostic results, and seven biopsies were false-negative. In noncontrast biopsies, the rate of insufficiently visualized lesions (grades 0-1) increased significantly during the procedure, from 10.5% to 44.7%, due to needle artifacts. This resulted in more (17.6%) false-negative biopsy results compared to lesions with good visualization (4.8%), although this difference lacks statistical significance. Visualization impairment appeared more often with an intercostal or subcostal vs. an epigastric access and with a subcapsular vs. a central lesion location, respectively. With contrast-enhanced biopsy the visibility of hepatic lesions was only temporarily improved, with a risk of complete obscuration in the late phase. Conclusion. In conclusion, visibility of small liver lesions diminished significantly during CT-guided biopsy due to needle artifacts, with a fourfold increased rate of insufficiently visualized lesions and of false-negative histological results. Contrast enhancement did not reveal better results

  13. Histological outcome of duodenal biopsies in patients with clinically suspected celiac disease - a study of 100 cases

    International Nuclear Information System (INIS)

    Sarfraz, T.; Khan, S.A.; Tariq, H.

    2018-01-01

    To see the histological outcome of duodenal biopsies done in patients clinically suspected of celiac disease. Study Design: Prospective descriptive study. Place and Duration of Study: Histopathology Department, Army Medical College Rawalpindi, from 1 Jan 2017 to 30 Jun 2017. Material and Methods: One hundred (100) cases were included in the study. Duodenal biopsies done in patients clinically suspected of celiac disease were included in the study. Inadequate biopsies were excluded from the study. All the normal and abnormal histological features were noted to make the diagnosis. Data was entered and analyzed by using SPSS version 17. Results: Duodenal biopsies of 100 patients, done in clinically suspected cases of celiac disease were analyzed histologically. Out of these 100 cases, 46 cases (46%) showed histological features consistent with celiac disease, while 38 cases (38%) revealed chronic non specific duodenitis, 2 cases (2%) were of giardiasis, while 14 biopsies (14%) were unremarkable with no significant pathology. Conclusion: A significant number of cases clinically suspected of celiac disease may not be showing histological features consistent with celiac disease on duodenal biopsies. Due to the changing presentation of disease, as well as the recognition of a number of potential clinical and histopathological mimics, communication between pathologists and gastroenterologists is essential for appropriate interpretation of duodenal biopsy specimens. (author)

  14. Use of diagnostic dynamic contrast-enhanced (DCE)-MRI for targeting of soft tissue tumour biopsies at 3T: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Noebauer-Huhmann, Iris-Melanie [Medical University of Vienna, Department of Biomedical Imaging and Image-guided Therapy, Division of Neuroradiology and Musculoskeletal Radiology, Vienna (Austria); Medical University of Vienna, High Field MR Center, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria); Medical University of Vienna/Vienna General Hospital, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria); Amann, Gabriele [Medical University of Vienna, Clinical Institute for Pathology, Vienna (Austria); Krssak, Martin [Medical University of Vienna, High Field MR Center, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria); Medical University of Vienna, Department of Internal Medicine III, Endocrinology and Metabolism, Vienna (Austria); Panotopoulos, Joannis; Funovics, Philipp; Windhager, Reinhard [Medical University of Vienna, Department of Orthopaedics, Vienna (Austria); Szomolanyi, Pavol [Medical University of Vienna, High Field MR Center, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria); Slovak Academy of Sciences, Department of Imaging Methods, Institute of Measurement Science, Bratislava (Slovakia); Weber, Michael; Czerny, Christian; Nemec, Stefan [Medical University of Vienna, Department of Biomedical Imaging and Image-guided Therapy, Division of Neuroradiology and Musculoskeletal Radiology, Vienna (Austria); Breitenseher, Martin [Landesklinikum Waldviertel Horn, Horn (Austria); Grabner, Guenther; Bogner, Wolfgang [Medical University of Vienna, High Field MR Center, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria); Dominkus, Martin [Orthopaedics Hospital Speising, Vienna (Austria); Trattnig, Siegfried [Medical University of Vienna, High Field MR Center, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria); Ludwig Boltzmann Institute for Experimental and Clinical Traumatology, Austrian Cluster for Tissue Regeneration, Vienna (Austria)

    2015-07-15

    To test the feasibility and accuracy of MR-guided soft tissue tumour biopsy at 3T, using the dynamic contrast-enhanced (DCE) information from staging MRI for intralesional targeting. After obtaining written informed consent for this institutional review board-approved study, 53 patients with suspected soft tissue tumours prospectively underwent preoperative staging MRI at 3T, including DCE, and subsequent MR-guided core needle biopsy. In 44/53 cases, DCE was heterogeneous and was used for intralesional biopsy targeting. Surgical, whole-specimen histology was used as the gold standard in 43/44 patients and revealed 42 soft tissue tumours (24 men; 18 women; mean age, 52 years; range, 19 - 84). Final surgical histology revealed eight benign lesions, six tumours of intermediate dignity, and 28 malignancies. All malignancies had shown heterogeneous DCE. The diagnostic yield of the biopsies was 100 % (42/42). Histological accuracy rates of biopsy were 100 % in predicting the dignity (42/42; 95 % CI [0.916 - 1.000]), 95.2 % for the tissue-specific entity (40/42; 95 % CI [0.847 - 0.987]), and 90.5 % for the tumour grade (38/42; 95 % CI [0.779 - 0.962]). Our preliminary study indicates that biopsy of soft tissue tumours can be performed accurately and safely with DCE targeted MR-guidance at 3T, using a combined staging/biopsy MRI protocol. (orig.)

  15. Use of diagnostic dynamic contrast-enhanced (DCE)-MRI for targeting of soft tissue tumour biopsies at 3T: preliminary results

    International Nuclear Information System (INIS)

    Noebauer-Huhmann, Iris-Melanie; Amann, Gabriele; Krssak, Martin; Panotopoulos, Joannis; Funovics, Philipp; Windhager, Reinhard; Szomolanyi, Pavol; Weber, Michael; Czerny, Christian; Nemec, Stefan; Breitenseher, Martin; Grabner, Guenther; Bogner, Wolfgang; Dominkus, Martin; Trattnig, Siegfried

    2015-01-01

    To test the feasibility and accuracy of MR-guided soft tissue tumour biopsy at 3T, using the dynamic contrast-enhanced (DCE) information from staging MRI for intralesional targeting. After obtaining written informed consent for this institutional review board-approved study, 53 patients with suspected soft tissue tumours prospectively underwent preoperative staging MRI at 3T, including DCE, and subsequent MR-guided core needle biopsy. In 44/53 cases, DCE was heterogeneous and was used for intralesional biopsy targeting. Surgical, whole-specimen histology was used as the gold standard in 43/44 patients and revealed 42 soft tissue tumours (24 men; 18 women; mean age, 52 years; range, 19 - 84). Final surgical histology revealed eight benign lesions, six tumours of intermediate dignity, and 28 malignancies. All malignancies had shown heterogeneous DCE. The diagnostic yield of the biopsies was 100 % (42/42). Histological accuracy rates of biopsy were 100 % in predicting the dignity (42/42; 95 % CI [0.916 - 1.000]), 95.2 % for the tissue-specific entity (40/42; 95 % CI [0.847 - 0.987]), and 90.5 % for the tumour grade (38/42; 95 % CI [0.779 - 0.962]). Our preliminary study indicates that biopsy of soft tissue tumours can be performed accurately and safely with DCE targeted MR-guidance at 3T, using a combined staging/biopsy MRI protocol. (orig.)

  16. Added value of second biopsy target in screen-detected widespread suspicious breast calcifications.

    Science.gov (United States)

    Falkner, Nathalie M; Hince, Dana; Porter, Gareth; Dessauvagie, Ben; Jeganathan, Sanjay; Bulsara, Max; Lo, Glen

    2018-06-01

    There is controversy on the optimal work-up of screen-detected widespread breast calcifications: whether to biopsy a single target or multiple targets. This study evaluates agreement between multiple biopsy targets within the same screen-detected widespread (≥25 mm) breast calcification to determine if the second biopsy adds value. Retrospective observational study of women screened in a statewide general population risk breast cancer mammographic screening program from 2009 to 2016. Screening episodes recalled for widespread calcifications where further views indicated biopsy, and two or more separate target areas were sampled within the same lesion were included. Percentage agreement and Cohen's Kappa were calculated. A total of 293317 women were screened during 761124 separate episodes with recalls for widespread calcifications in 2355 episodes. In 171 women, a second target was biopsied within the same lesion. In 149 (86%) cases, the second target biopsy result agreed with the first biopsy (κ = 0.6768). Agreement increased with increasing mammography score (85%, 86% and 92% for score 3, 4 and 5 lesions). Same day multiple biopsied lesions were three times more likely to yield concordant results compared to post-hoc second target biopsy cases. While a single target biopsy is sufficient to discriminate a benign vs. malignant diagnosis in most cases, in 14% there is added value in performing a second target biopsy. Biopsies performed prospectively are more likely to yield concordant results compared to post-hoc second target biopsy cases, suggesting a single prospective biopsy may be sufficient when results are radiological-pathological concordant; discordance still requires repeat sampling. © 2018 The Royal Australian and New Zealand College of Radiologists.

  17. THE PROGNOSTIC AND DIAGNOSTIC VALUE OF REPEATED TRANSRECTAL PROSTATE SATURATION BIOPSY

    Directory of Open Access Journals (Sweden)

    M. A. Kurdzhiev

    2014-08-01

    Full Text Available Objective: to determine the rate of prostate cancer (PC development after repeated transrectal saturation prostate biopsy (RTRSPB, to study the characteristics of diagnosed tumors, and to estimate their clinical significance from the data of radical retropubic prostatectomy (RRP.Materials and methods. The results of RTRSPB were analyzed in 226 patients with a later evaluation of a tumor from the results of RRP. All the patients underwent at least 2 prostate biopsies (mean 2.4. The average number of biopsy cores was 26.7 (range 24—30. The average value of total prostate-specific antigen before saturation biopsy was 7.5 (range 7.5 to 28.6 ng/ml. The mean age of patients was 62 years (range 53 to 70.  Results. PC was diagnosed in 14.6% of cases (33/226. An isolated lesion of the prostatic transition zone was in 12.1% of cases. If this zone had been excluded from the biopsy scheme, the detection rate of PC during saturation biopsy should be reduced by 13.8%. Better PC detectability during repeated saturation biopsy generally occurred due to the localized forms of the disease (93.3%. The agreement of Gleason tumor grading in the biopsy and prostatectomy specimens was noted in 66.7% of cases.Conclusion. Saturation biopsy allows prediction of a pathological stage of PC, Gleason grade of a tumor and its site localization with a greater probability. Most tumors detectable by saturation biopsy were clinically significant, which makes it possible to recommend RTRSPB to some cohort of high PC-risk patients 

  18. Retroperitoneoscopic renal biopsy in children

    Directory of Open Access Journals (Sweden)

    Carlos M. Jesus

    2007-08-01

    Full Text Available OBJECTIVE: We present our experience in a series of 17 consecutive pediatric patients submitted to retroperitoneal laparoscopic renal biopsy. MATERIALS AND METHODS: Retroperitoneal laparoscopic renal biopsy (LRB was performed in 5 boys and 12 girls. Mean age was 8.1 years and age range from 2 to 12. Two or three trocars were used to expose the inferior pole of the kidney, remove enough cortical parenchymal specimen and fulgurate the biopsy site. Assessment included surgical time, estimated blood loss, hospitalization period, analgesia requirements, complications and number of glomeruli present in the specimen. RESULTS: LRB was successfully performed in all 15 patients (88%. In two cases, LRB was not possible to be performed. One patient was converted to a transperitoneal laparoscopy due to tear in the peritoneum. The other patient had had previous abdominal surgery and, during retroperitoneal balloon dilation, the peritoneum was opened and the open biopsy was performed. A third patient had postoperatively a perirenal hematoma, which was solved spontaneously. Complication rate was 17.6% (3/17 cases. Mean operative time was 65 minutes, while mean estimated blood loss was 52 mL, mean hospital stay was 2.2 days and mean analgesic requirement was 100 mg of tramadol. The mean number of glomeruli present in the specimen was 60. CONCLUSION: Retroperitoneal laparoscopic renal biopsy in children is a simple, safe. Bleeding is still the most common complication. However, direct vision usually allows a safe control of this drawback. In our institution, laparoscopic approach is the chosen procedure in pediatric patients older than one - year - old.

  19. Comparison of CT and PET/CT for biopsy guidance in oncological patients

    Energy Technology Data Exchange (ETDEWEB)

    Cerci, Juliano J.; Bogoni, Mateos; Cunha Pereira, Carlos; Cerci, Rodrigo J.; Krauzer, Cassiano; Vicente Vitola, Joao [Quanta - Diagnostico e Terapia, Curitiba, PR (Brazil); Tabacchi, Elena; Fanti, Stefano [University Hospital S. Orsola-Malpighi, Nuclear Medicine Department, Bologna (Italy); Delbeke, Dominique [Vanderbilt University, Nashville, TN (United States); Giacometti Sakamoto, Danielle [Byori - Laboratorio de Patologia, Curitiba (Brazil)

    2017-08-15

    To compare FDG PET/CT and CT for the guidance of percutaneous biopsies with histological confirmation of lesions. We prospectively evaluated 323 patients of whom 181 underwent FDG PET/CT-guided biopsy (total 188 biopsies) and 142 underwent CT-guided biopsy (total 146 biopsies). Biopsies were performed using the same PET/CT scanner with a fluoroscopic imaging system. Technical feasibility, clinical success and complication rates in the two groups were evaluated. Of the 188 biopsies with PET/CT guidance, 182 (96.8%) were successful with conclusive tissue samples obtained and of the 146 biopsies with CT guidance, 137 (93.8%) were successful. Therefore, 6 of 188 biopsies (3.1%) with PET/CT guidance and 9 of 146 (6.1%) with CT guidance were inconclusive (p = 0.19). Due to inconclusive histological results, 4 of the 188 lesions (2.1%) were rebiopsied with PET/CT guidance and 3 of 146 lesions (2.0%) were rebiopsied with CT guidance. Histology demonstrated that 142 of 188 lesions (75.5%) were malignant, and 40 (21.2%) were benign in the PET/CT-guided group, while 89 of 146 lesions (60.9%) were malignant and 48 (32.8%) were benign in the CT-guided group (p = 0.004 and 0.01, respectively). Patients with a histological diagnosis of benign lesion had no recurrence of disease with a minimum of 6 months follow-up. Of the 188 PET/CT-guided biopsies, 6 (3.1%) were repeat biopsies due to a previous nondiagnostic CT-guided biopsy performed in a different diagnostic centre. The interval between the two biopsies was less than a month in all cases. Histology revealed five malignant lesions and one benign lesion among these. The complication rate in the PET/CT-guided biopsy group was 12.7% (24 of 188), while in the CT-guided group, was 9.5% (14 of 146, p = 0.26). Therefore, there was no significant difference in complication rates between PET/CT and CT guidance. PET/CT-guided biopsy is already known to be a feasible and accurate method in the diagnostic work-up of suspected malignant

  20. Comparison of CT and PET/CT for biopsy guidance in oncological patients

    International Nuclear Information System (INIS)

    Cerci, Juliano J.; Bogoni, Mateos; Cunha Pereira, Carlos; Cerci, Rodrigo J.; Krauzer, Cassiano; Vicente Vitola, Joao; Tabacchi, Elena; Fanti, Stefano; Delbeke, Dominique; Giacometti Sakamoto, Danielle

    2017-01-01

    To compare FDG PET/CT and CT for the guidance of percutaneous biopsies with histological confirmation of lesions. We prospectively evaluated 323 patients of whom 181 underwent FDG PET/CT-guided biopsy (total 188 biopsies) and 142 underwent CT-guided biopsy (total 146 biopsies). Biopsies were performed using the same PET/CT scanner with a fluoroscopic imaging system. Technical feasibility, clinical success and complication rates in the two groups were evaluated. Of the 188 biopsies with PET/CT guidance, 182 (96.8%) were successful with conclusive tissue samples obtained and of the 146 biopsies with CT guidance, 137 (93.8%) were successful. Therefore, 6 of 188 biopsies (3.1%) with PET/CT guidance and 9 of 146 (6.1%) with CT guidance were inconclusive (p = 0.19). Due to inconclusive histological results, 4 of the 188 lesions (2.1%) were rebiopsied with PET/CT guidance and 3 of 146 lesions (2.0%) were rebiopsied with CT guidance. Histology demonstrated that 142 of 188 lesions (75.5%) were malignant, and 40 (21.2%) were benign in the PET/CT-guided group, while 89 of 146 lesions (60.9%) were malignant and 48 (32.8%) were benign in the CT-guided group (p = 0.004 and 0.01, respectively). Patients with a histological diagnosis of benign lesion had no recurrence of disease with a minimum of 6 months follow-up. Of the 188 PET/CT-guided biopsies, 6 (3.1%) were repeat biopsies due to a previous nondiagnostic CT-guided biopsy performed in a different diagnostic centre. The interval between the two biopsies was less than a month in all cases. Histology revealed five malignant lesions and one benign lesion among these. The complication rate in the PET/CT-guided biopsy group was 12.7% (24 of 188), while in the CT-guided group, was 9.5% (14 of 146, p = 0.26). Therefore, there was no significant difference in complication rates between PET/CT and CT guidance. PET/CT-guided biopsy is already known to be a feasible and accurate method in the diagnostic work-up of suspected malignant

  1. Development and Evaluation of a Novel Curved Biopsy Device for CT-Guided Biopsy of Lesions Unreachable Using Standard Straight Needle Trajectories

    Energy Technology Data Exchange (ETDEWEB)

    Schulze-Hagen, Maximilian Franz, E-mail: mschulze@ukaachen.de; Pfeffer, Jochen; Zimmermann, Markus; Liebl, Martin [University Hospital RWTH Aachen, Department of Diagnostic and Interventional Radiology (Germany); Stillfried, Saskia Freifrau von [University Hospital RWTH Aachen, Department of Pathology (Germany); Kuhl, Christiane; Bruners, Philipp; Isfort, Peter [University Hospital RWTH Aachen, Department of Diagnostic and Interventional Radiology (Germany)

    2017-06-15

    PurposeTo evaluate the feasibility of a novel curved CT-guided biopsy needle prototype with shape memory to access otherwise not accessible biopsy targets.Methods and MaterialsA biopsy needle curved by 90° with specific radius was designed. It was manufactured using nitinol to acquire shape memory, encased in a straight guiding trocar to be driven out for access of otherwise inaccessible targets. Fifty CT-guided punctures were conducted in a biopsy phantom and 10 CT-guided punctures in a swine corpse. Biposies from porcine liver and muscle tissue were separately gained using the biopsy device, and histological examination was performed subsequently.ResultsMean time for placement of the trocar and deployment of the inner biopsy needle was ~205 ± 69 and ~93 ± 58 s, respectively, with a mean of ~4.5 ± 1.3 steps to reach adequate biopsy position. Mean distance from the tip of the needle to the target was ~0.7 ± 0.8 mm. CT-guided punctures in the swine corpse took relatively longer and required more biopsy steps (~574 ± 107 and ~380 ± 148 s, 8 ± 2.6 steps). Histology demonstrated appropriate tissue samples in nine out of ten cases (90%).ConclusionsTargets that were otherwise inaccessible via standard straight needle trajectories could be successfully reached with the curved biopsy needle prototype. Shape memory and preformed size with specific radius of the curved needle simplify the target accessibility with a low risk of injuring adjacent structures.

  2. Morphological pattern of endometrial biopsies in southwestern Nigeria

    African Journals Online (AJOL)

    Background: Endometrium remains the most sensitive indicator of ovarian function and endometrial biopsy is one of the diagnostic procedures in endometrial pathology. The current study was carried out to examine the morphological pattern of endometrial biopsies in Ibadan, South-western Nigeria and compare the results ...

  3. Does Prebiopsy, Nonsterile Ultrasonography Gel Affect Biopsy-Site Asepsis?

    International Nuclear Information System (INIS)

    Gurel, Kamil; Karabay, Oguz; Gurel, Safiye; Hildebolt, Charles

    2008-01-01

    Purpose. The purpose of this study was to determine the extent to which the use of nonsterile gel, prior to antiseptic procedures in ultrasonography (US)-guided percutaneous biopsies, results in contamination of the biopsy site. Materials and Methods. Patients referred for US-guided percutaneous biopsies were included in this study. Transmission material used for US evaluation before biopsy-site antiseptic procedures were performed was either nonsterile gel or sterile saline. Patients were randomly assigned to two groups: nonsterile gel (n = 30) and sterile saline (n = 30). Before the transmission material was used and after antiseptic procedures were performed, microbial swabs of a 10-cm 2 -diameter area were obtained at the biopsy site. Swabs were also obtained from the gel, saline, and povidine-iodine. Inoculated specimen plates were incubated at 37 o C under aerobic conditions, and the numbers of colony-forming units recorded. Nominal logistic regression analysis was used to calculate the odds of postantisepsis bacterial growth (after antiseptic procedures were performed) based on group, gender, coincidental disease (diabetes, chronic renal failure, and malignancy), biopsy-site location (head and neck or breast and abdomen), and local factors (skin fold, skin tag, and hair). Results. The following odds ratios (adjusted for the other variables) and their 95% confidence intervals were calculated: (1) group (2.9 [0.8-11.1]; p = 0.10); (2) gender (1.2 [0.3-5.2]; p = 0.78); (3) coincidental disease (7.6 [0.9-166.7]; p = 0.09); (4) biopsy site location (6.2 [1.4-31.3]; p = 0.02); and (5) local factors (7.0 [1.6-36.0]; p = 0.01). No bacterial growth occurred with swabs obtained from gel, povidine-iodine, or saline. Conclusion. We conclude that nonsterile gel used prior to percutaneous biopsy does not affect biopsy-site asepsis

  4. A Novel Design of Needle Aspiration Biopsy Monitoring Instrument (NAOMI Tested on a Low Cost Chest Phantom

    Directory of Open Access Journals (Sweden)

    Surakusumah Rino Ferdian

    2016-01-01

    Full Text Available Needle biopsy is a medical intervention method for taking a lung tissue sample that suspected as a cancer. The disadvantage is the physicians directly visualize the anatomical structures in an open surgery for lung cancer biopsy procedure. There is a need to develop an instrument that may help the physician to guarantee the accuracy and efficiency while performing needle aspiration biopsy. Therefore, a needle aspiration biopsy monitoring instrument or named as NAOMI is proposed. It consists of a microcontroller system, an IMU sensor, an ultrasonic ranging module, a bluetooth module, and a 9V lithium battery. The experimental testing consist of performance testing, functional testing using chest phantom, and user acceptances. The results showed that the NAOMI improve the accuracy and efficiency while performing the needle biopsy operation.

  5. In-bore transrectal MRI-guided prostate biopsies: Are there risk factors for complications?

    Energy Technology Data Exchange (ETDEWEB)

    Meier-Schroers, Michael, E-mail: michael.meier@ukb.uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Str 25, 53127 Bonn (Germany); Homsi, Rami, E-mail: rami.homsi@ukb.uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Str 25, 53127 Bonn (Germany); Kukuk, Guido, E-mail: guido.kukuk@ukb.uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Str 25, 53127 Bonn (Germany); Wolter, Karsten, E-mail: karsten.wolter@ukb.uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Str 25, 53127 Bonn (Germany); Decker, Georges, E-mail: georges.decker@ukb.uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Str 25, 53127 Bonn (Germany); Fischer, Stefan, E-mail: stefan.fischer@ukb.uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Str 25, 53127 Bonn (Germany); Marx, Christian, E-mail: christian.marx@ukb.uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Str 25, 53127 Bonn (Germany); Schmeel, Frederic Carsten, E-mail: carsten.schmeel@ukb.uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Str 25, 53127 Bonn (Germany); Block, Wolfgang, E-mail: wolfgang.block@ukb.uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Str 25, 53127 Bonn (Germany); Sprinkart, Alois Martin, E-mail: sprinkart@uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Str 25, 53127 Bonn (Germany); Traeber, Frank, E-mail: frank.traeber@ukb.uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Str 25, 53127 Bonn (Germany); Schild, Hans Heinz, E-mail: hans.schild@ukb.uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Str 25, 53127 Bonn (Germany); Willinek, Winfried, E-mail: w.willinek@bk-trier.de [Department of Radiology, Neuroradiology, Sonography and Nuclear Medicine, Hospital of the Barmherzige Brüder Trier, Nordallee 1, 54292 Trier (Germany)

    2016-12-15

    Purpose: To systematically analyze risk factors for complications of in-bore transrectal MRI-guided prostate biopsies (MRGB). Materials and methods: 90 patients, who were scheduled for MRGB were included for this study. Exclusion criteria were coagulation disorders, therapy with anticoagulant drugs, and acute infections of the urinary and the lower gastrointestinal tract. Directly after, one week and one year after the biopsy, we assessed biopsy related complications (e.g. hemorrhages or signs of prostatitis). Differences between patients with and without complications were analyzed regarding possible risk factors: age, prostate volume, number of taken samples, biopsy duration, biopsy of more than one lesion, diabetes, arterial hypertension, hemorrhoids, benign prostate hyperplasia, carcinoma or prostatitis (according to histopathological analysis), and lesion localization. Complications were classified according to the Clavien-Dindo classification. Results: We observed 15 grade I complications in 90 biopsies (16.7%) with slight hematuria in 9 cases (10%), minor vasovagal reactions in 4 cases (4.4%), and urinary retention and positioning-related facial dysesthesia in 1 case each (1.1%). One patient showed acute prostatitis requiring antibiotics as the only grade II complication (1.1%). There were no adverse events that occurred later than one week. Complications grade III or higher such as pelvic abscesses, urosepsis or severe hemorrhages were not seen. There were no significant associations between the assessed risk factors and biopsy-related complications. Conclusion: In-bore transrectal MRI-guided prostate biopsies can be considered safe procedures in the diagnosis of prostate cancer with very low complication rates. There seem to be no risk factors for complications.

  6. In-bore transrectal MRI-guided prostate biopsies: Are there risk factors for complications?

    International Nuclear Information System (INIS)

    Meier-Schroers, Michael; Homsi, Rami; Kukuk, Guido; Wolter, Karsten; Decker, Georges; Fischer, Stefan; Marx, Christian; Schmeel, Frederic Carsten; Block, Wolfgang; Sprinkart, Alois Martin; Traeber, Frank; Schild, Hans Heinz; Willinek, Winfried

    2016-01-01

    Purpose: To systematically analyze risk factors for complications of in-bore transrectal MRI-guided prostate biopsies (MRGB). Materials and methods: 90 patients, who were scheduled for MRGB were included for this study. Exclusion criteria were coagulation disorders, therapy with anticoagulant drugs, and acute infections of the urinary and the lower gastrointestinal tract. Directly after, one week and one year after the biopsy, we assessed biopsy related complications (e.g. hemorrhages or signs of prostatitis). Differences between patients with and without complications were analyzed regarding possible risk factors: age, prostate volume, number of taken samples, biopsy duration, biopsy of more than one lesion, diabetes, arterial hypertension, hemorrhoids, benign prostate hyperplasia, carcinoma or prostatitis (according to histopathological analysis), and lesion localization. Complications were classified according to the Clavien-Dindo classification. Results: We observed 15 grade I complications in 90 biopsies (16.7%) with slight hematuria in 9 cases (10%), minor vasovagal reactions in 4 cases (4.4%), and urinary retention and positioning-related facial dysesthesia in 1 case each (1.1%). One patient showed acute prostatitis requiring antibiotics as the only grade II complication (1.1%). There were no adverse events that occurred later than one week. Complications grade III or higher such as pelvic abscesses, urosepsis or severe hemorrhages were not seen. There were no significant associations between the assessed risk factors and biopsy-related complications. Conclusion: In-bore transrectal MRI-guided prostate biopsies can be considered safe procedures in the diagnosis of prostate cancer with very low complication rates. There seem to be no risk factors for complications.

  7. Closed pleural biopsy is still useful in the evaluation of malignant pleural effusion

    Directory of Open Access Journals (Sweden)

    Somnath Bhattacharya

    2012-01-01

    Full Text Available Background: Pleural fluid cytology for malignant cells is the easiest way to diagnose malignant pleural effusion with good sensitivity and specificity. With the introduction of medical thoracoscopy, the use of closed pleural biopsy for the diagnosis of cytology negative malignant pleural effusion is gradually decreasing. However use of thoracoscopy is limited due to its high cost and procedure related complications. Aims: The aim was to assess the usefulness of closed pleural biopsy in the diagnosis of malignant pleural effusion. Materials and Methods: Sixty-six patients of pleural effusion associated with malignancy were selected from the patients admitted in the chest ward of a tertiary care hospital over a period of 1 year. Pleural fluid aspiration for cytology and closed pleural biopsy were done in all the patients. Results: Out of 66 patients, 46 (69% patients showed malignant cells in pleural fluid cytology examination. Cytology was positive in 35 (52%, 10 (15%, and 1 (1.5% patients in the first, second, and third samples respectively. Closed pleural biopsy was positive in 32 (48% patients. Among them, 22 also had positive cytology. Additional 10 cytology negative patients were diagnosed by pleural biopsy. Cytology-histology concordance was seen in 12 patients. Definite histological diagnosis could be achieved in five patients with indeterminate cytology. Pleural biopsy was not associated with any major postoperative complication. Conclusion: Closed pleural biopsy can improve the diagnostic ability in cytology negative malignant pleural effusion. Closed pleural biopsy has still a place in evaluation of malignant pleural effusion especially in a resource-limited country like India.

  8. Validation of morphometric analyses of small-intestinal biopsy readouts in celiac disease.

    Directory of Open Access Journals (Sweden)

    Juha Taavela

    Full Text Available BACKGROUND: Assessment of the gluten-induced small-intestinal mucosal injury remains the cornerstone of celiac disease diagnosis. Usually the injury is evaluated using grouped classifications (e.g. Marsh groups, but this is often too imprecise and ignores minor but significant changes in the mucosa. Consequently, there is a need for validated continuous variables in everyday practice and in academic and pharmacological research. METHODS: We studied the performance of our standard operating procedure (SOP on 93 selected biopsy specimens from adult celiac disease patients and non-celiac disease controls. The specimens, which comprised different grades of gluten-induced mucosal injury, were evaluated by morphometric measurements. Specimens with tangential cutting resulting from poorly oriented biopsies were included. Two accredited evaluators performed the measurements in blinded fashion. The intraobserver and interobserver variations for villus height and crypt depth ratio (VH:CrD and densities of intraepithelial lymphocytes (IELs were analyzed by the Bland-Altman method and intraclass correlation. RESULTS: Unevaluable biopsies according to our SOP were correctly identified. The intraobserver analysis of VH:CrD showed a mean difference of 0.087 with limits of agreement from -0.398 to 0.224; the standard deviation (SD was 0.159. The mean difference in interobserver analysis was 0.070, limits of agreement -0.516 to 0.375, and SD 0.227. The intraclass correlation coefficient in intraobserver variation was 0.983 and that in interobserver variation 0.978. CD3(+ IEL density countings in the paraffin-embedded and frozen biopsies showed SDs of 17.1% and 16.5%; the intraclass correlation coefficients were 0.961 and 0.956, respectively. CONCLUSIONS: Using our SOP, quantitative, reliable and reproducible morphometric results can be obtained on duodenal biopsy specimens with different grades of gluten-induced injury. Clinically significant changes were

  9. Diabetic mastopathy: Imaging features and the role of image-guided biopsy in its diagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jong Hyeon; Kim, Eun Kyung; Kim, Min Jung; Moon, Hee Jung; Yoon, Jung Hyun [Dept. of Radiology, Research Institute of Radiological Science, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2016-03-15

    The goal of this study was to evaluate the imaging features of diabetic mastopathy (DMP) and the role of image-guided biopsy in its diagnosis. Two experienced radiologists retrospectively reviewed the mammographic and sonographic images of 19 pathologically confirmed DMP patients. The techniques and results of the biopsies performed in each patient were also reviewed. Mammograms showed negative findings in 78% of the patients. On ultrasonography (US), 13 lesions were seen as masses and six as non-mass lesions. The US features of the mass lesions were as follows: irregular shape (69%), oval shape (31%), indistinct margin (69%), angular margin (15%), microlobulated margin (8%), well-defined margin (8%), heterogeneous echogenicity (62%), hypoechoic echogenicity (38%), posterior shadowing (92%), parallel orientation (100%), the absence of calcifications (100%), and the absence of vascularity (100%). Based on the US findings, 17 lesions (89%) were classified as Breast Imaging Reporting and Data System category 4 and two (11%) as category 3. US-guided core biopsy was performed in 18 patients, and 10 (56%) were diagnosed with DMP on that basis. An additional vacuum-assisted biopsy was performed in seven patients and all were diagnosed with DMP. The US features of DMP were generally suspicious for malignancy, whereas the mammographic findings were often negative or showed only focal asymmetry. Core biopsy is an adequate method for initial pathological diagnosis. However, since it yields non-diagnostic results in a considerable number of cases, the evaluation of correlations between imaging and pathology plays an important role in the diagnostic process.

  10. Diabetic mastopathy: Imaging features and the role of image-guided biopsy in its diagnosis

    International Nuclear Information System (INIS)

    Kim, Jong Hyeon; Kim, Eun Kyung; Kim, Min Jung; Moon, Hee Jung; Yoon, Jung Hyun

    2016-01-01

    The goal of this study was to evaluate the imaging features of diabetic mastopathy (DMP) and the role of image-guided biopsy in its diagnosis. Two experienced radiologists retrospectively reviewed the mammographic and sonographic images of 19 pathologically confirmed DMP patients. The techniques and results of the biopsies performed in each patient were also reviewed. Mammograms showed negative findings in 78% of the patients. On ultrasonography (US), 13 lesions were seen as masses and six as non-mass lesions. The US features of the mass lesions were as follows: irregular shape (69%), oval shape (31%), indistinct margin (69%), angular margin (15%), microlobulated margin (8%), well-defined margin (8%), heterogeneous echogenicity (62%), hypoechoic echogenicity (38%), posterior shadowing (92%), parallel orientation (100%), the absence of calcifications (100%), and the absence of vascularity (100%). Based on the US findings, 17 lesions (89%) were classified as Breast Imaging Reporting and Data System category 4 and two (11%) as category 3. US-guided core biopsy was performed in 18 patients, and 10 (56%) were diagnosed with DMP on that basis. An additional vacuum-assisted biopsy was performed in seven patients and all were diagnosed with DMP. The US features of DMP were generally suspicious for malignancy, whereas the mammographic findings were often negative or showed only focal asymmetry. Core biopsy is an adequate method for initial pathological diagnosis. However, since it yields non-diagnostic results in a considerable number of cases, the evaluation of correlations between imaging and pathology plays an important role in the diagnostic process

  11. Liver biopsy under hypnosis.

    Science.gov (United States)

    Adams, P C; Stenn, P G

    1992-09-01

    Two patients underwent outpatient percutaneous liver biopsy under hypnosis without complications. One patient had severe anxiety about the procedure because of a previous adverse experience with liver biopsy and the other had a history of severe allergy to local anesthesia. Both patients had undergone a session of hypnosis at least once prior to the biopsy. One received no local anesthetic and the other received 1% lidocaine as a local anesthetic. Both patients were completely cooperative during the procedure with the required respiratory maneuvers. Both patients stated that they were aware of the procedure under hypnosis but described no pain and would be most willing to have the procedure done under hypnosis in the future. Hypnosis can be a useful method of preparing carefully selected patients for percutaneous liver biopsy.

  12. Biopsy-proven childhood glomerulonephritis in Johor.

    Science.gov (United States)

    Khoo, J J; Pee, S; Thevarajah, B; Yap, Y C; Chin, C K

    2004-06-01

    There has been no published study of biopsy-proven childhood glomerulonephritis in Malaysia. To determine the pattern of childhood glomerulonephritis in Johor, Malaysia from a histopathological perspective and the various indications used for renal biopsy in children. Retrospective study was done of all renal biopsies from children under 16 years of age, received in Sultanah Aminah Hospital, Johor between 1994 and 2001. The histopathological findings were reviewed to determine the pattern of biopsy-proven glomerulonephritis. The indications for biopsy, mode of therapy given after biopsy and the clinical outcome were studied. 122 adequate biopsies were received, 9 children had repeat biopsies. Of the 113 biopsies, minimal change disease formed the most common histopathological diagnosis (40.7%) while lupus nephritis formed the most common secondary glomerulonephritis (23.0%). The main indications for biopsy were nephrotic syndrome (50.8%), lupus nephritis (25.4%) and renal impairment (13.1%). The mode of therapy was changed in 59.8% of the children. Of 106 patients followed-up, 84 children were found to have normal renal function in remission or on treatment. 4 patients developed chronic renal impairment and 16 reached end stage renal disease. Five of the 16 children with end stage disease had since died while 11 were on renal replacement therapy. Another 2 patients died of other complications. The pattern of childhood GN in our study tended to reflect the more severe renal parenchymal diseases in children and those requiring more aggressive treatment. This was because of our criteria of selection (indication) for renal biopsy. Renal biopsy where performed appropriately in selected children may not only be a useful investigative tool for histological diagnosis and prognosis but may help clinicians plan the optimal therapy for these children.

  13. Repeated biopsies in prostate cancer patients on active surveillance

    DEFF Research Database (Denmark)

    Thomsen, Frederik Birkebaek; Marcussen, Niels; Berg, Kasper Drimer

    2015-01-01

    OBJECTIVE: To investigate the clinical implications of interobserver variation in the assessment of re-biopsies obtained during active surveillance (AS). MATERIAL AND METHODS: A total of 107 low-risk prostate cancer patients with a total of 93 diagnostic biopsy sets and 109 re-biopsy sets were...... included. The ISUP 2005 Gleason scoring system was applied for the histopathological assessment of all biopsies. Three different definitions of histopathological progression were applied. Unweighted and linear weighted Kappa statistics were used to compare the interobserver agreement. RESULTS: The overall...... recommendations would have changed in up to 10.1% (95% CI: 5.4%-17.7%) of the 109 re-biopsy sets. CONCLUSION: Kappa statistics demonstrated a strong agreement between the histological evaluations. Still, up to 10% of AS patients would receive different treatment recommendation depending upon which...

  14. Robot-assisted biopsies in a high-field MRI system. First clinical results; Roboterunterstuetzte Punktion in einem Hochfeld-Kernspintomografen. Erste klinische Ergebnisse

    Energy Technology Data Exchange (ETDEWEB)

    Schell, B.; Eichler, K.; Mack, M.G.; Mueller, C.; Kerl, J.M.; Beeres, M.; Thalhammer, A.; Vogl, T.J.; Zangos, S. [Frankfurt Univ. (Germany). Inst. fuer Diagnostische und Interventionelle Radiologie; Czerny, C. [Frankfurt Univ. (Germany). Inst. fuer Unfall-, Hand- und Wiederherstellungschirurgie

    2012-01-15

    Purpose: The purpose of this study was to examine the clinical use of MR-guided biopsies in patients with suspicious lesions using a new MR-compatible assistance system in a high-field MR system. Materials and Methods: Six patients with suspicious focal lesions in various anatomic regions underwent percutanous biopsy in a high-field MR system (1.5 T, Magnetom Espree, Siemens) using a new MR-compatible assistance system (Innomotion). The procedures were planned and guided using T1-weighted FLASH and TrueFISP sequences. A servopneumatic drive then moved the guiding arm automatically to the insertion point. An MRI compatible 15G biopsy system (Somatex) was introduced by a physician guided by the needle holder and multiple biopsies were performed using the coaxial technique. The feasibility, duration of the intervention and biopsy findings were analyzed. Results: The proposed new system allows accurate punctures in a high-field MR system. The assistance device did not interfere with the image quality, and guided the needle virtually exactly as planned. Histological examination could be conducted on every patient. The lesion was malignant in four cases, and an infectious etiology was diagnosed for the two remaining lesions. Regarding the differentiation of anatomical and pathological structures and position monitoring of the insertion needle, TrueFISP images are to be given preference. The average intervention time was 41 minutes. Lesions up to 15.4 cm beneath the skin surface were punctured. Conclusion: The proposed MR-guided assistance system can be successfully utilized in a high-field MR system for accurate punctures of even deep lesions in various anatomic regions. (orig.)

  15. Ultrasound-guided forceps for pleural biopsy

    Directory of Open Access Journals (Sweden)

    Gamal Agmy

    2014-04-01

    Clinical implications: Ultrasound-guided forceps for pleural biopsy can overcome many of the limitations of the conventional needle biopsy procedures, provides multiple biopsy specimens of the parietal pleura that are inaccessible to the biopsy needle, and can be carried out easily and safely even in sick and obese patients. The diagnostic yield is nearly similar to thoracoscopy.

  16. The Effectiveness of Mapping Biopsy in Patients with Extramammary Paget's Disease

    Directory of Open Access Journals (Sweden)

    Byung Jun Kim

    2014-11-01

    Full Text Available BackgroundExtramammary Paget's disease (EMPD is an intraepithelial carcinoma usually occurring on the skin or mucosa of the perineum. Clinically, it resembles eczema or dermatitis, and misdiagnosis and treatment delays are common. The treatment of choice for EMPD is a wide excision with adequate margins. Wide excision with intraoperative frozen biopsy and Mohs micrographic surgery are common methods; however, these are associated with a high recurrence rate and long operation time, respectively.MethodsBetween January 2010 and June 2013, 21 patients diagnosed with EMPD underwent mapping biopsy. Biopsy specimens were collected from at least 10 areas, 2 cm from the tumor margin. When the specimens were positive for malignancy, additional mapping biopsy was performed around the biopsy site of the positive result, and continued until no cancer cells were found. Based on the results, excision margins and reconstruction plans were established preoperatively.ResultsThe patients (18 male, 3 female had a mean age of 66.5 years (range, 50-82 years. Almost all cases involved in the perineal area, except one case of axillary involvement. Permanent biopsy revealed one case (4.8% of positive cancer cells on the resection margin, in which additional mapping biopsy and re-operation was performed. At the latest follow-up (mean, 27.4 months; range, 12-53 months, recurrence had not occurred.ConclusionsPreoperative mapping biopsy enables accurate resection margins and a preoperative reconstructing plan. Additionally, it reduces the operation time and risk of recurrence. Accordingly, it represents an effective alternative to Mohs micrographic surgery and wide excision with intraoperative frozen biopsy.

  17. Seven cases of upper gastrointestinal bleeding after cold biopsy

    OpenAIRE

    Alneaimi, Khaled; Abdelmoula, Ali; Vincent, Magalie; Savale, Camille; Baye, Birane; Lesur, Gilles

    2016-01-01

    Background and study aims: Routine biopsy of the upper gastrointestinal tract is performed with increasing frequency. It is generally considered to be safe without significant complication. However, gastrointestinal bleeding as a result of cold biopsy is a known complication. We report seven cases of upper gastrointestinal bleeding after cold biopsy and discuss clinical data, risks factors, severity and management of this event. We suggest that physicians must be more cautious with this rare ...

  18. Ultrasound-guided biopsy of transplanted pancreas: evaluation of 20 cases

    Directory of Open Access Journals (Sweden)

    Marcel Vieira da Nóbrega

    2009-03-01

    Full Text Available Objective: To report the experience with percutaneous biopsies of pancreatic grafts guided by ultrasonography. Methods: Series of cases referred from outpatient’s clinic for biopsy of pancreas transplant, between December 2006 and March 2008. Data were collected from medical electronic records for age, sex and histopathology. The indication for the procedure was obtained from medical and laboratory records. Doppler ultrasonography was performed for control and to guide biopsy in real time. Rresults: Twenty patients referred for biopsy of their transplanted pancreas over a one-year period were evaluated. In one patient, biopsy was not performed for having no safe access for ultrasound. It was used 18 gauge needles, mostly automatic-cut type. The main indications were increased blood glucose and pancreatic enzyme levels as well as reduction of urinary amylase. The sonographic aspect of the pancreatic graft was normal in 18 cases. In all 19 biopsies performed, satisfactory samples for histopathological study were obtained. There were no complications. Cconclusions: This series of cases demonstrated low sensitivity and specificity of ultrasound in diagnosis of pancreatic transplants disorders, but showed to be very useful to guide transplanted pancreas biopsies. Although no complications occurred in this experience, the risk-benefit relation should always be assessed for every patient.

  19. Value of Diffusion Tensor Imaging of Prostate Cancer: Comparison with Systemic Prostate Biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Seong Kuk; Kim, Dong Won; Ha, Dong Ho; Kwon, Hee Jin; Kang, Myong Jin; Choi, Sun Seob; Nam, Kyung Jin; Kim, Jung Il [Dong-A University, Medical Center, Busan (Korea, Republic of)

    2011-02-15

    This study was performed to evaluate the usefulness of diffusion tensor imaging (DTI) and to correlate systemic twelve biopsy in prostate cancer. Thirty-one patients with suspected prostate cancer underwent MR imaging. DTI was performed prior to a prostate biopsy. We prospectively calculated the apparent diffusion coefficient (ADC) and fractional anisotropy (FA) value in each corresponding biopsy site. Twenty-three of 31 patients had histopathologically proven adenocarcinoma. Among the 276 biopsy cores of 23 patients with prostate cancer, 109 cores showed positive results (39%). The ADC and FA value of positive cores were 1.31 {+-} 0.34x10-3 mm2/s and 0.68 {+-} 0.07, and those of the negative cores were 1.74 {+-} 0.45x10-3 mm2/s and 0.54 {+-} 0.09, respectively. Eight patients without carcinoma showed an ADC value of 1.83 {+-} 0.26x10-3 mm2/s and an FA value of 0.47 {+-} 0.07. The ADC and FA value of positive cores were significantly lower and higher than those of negative cores and cancer-free patients, respectively (p < 0.05). The ADC and FA values using DTI may provide useful diagnostic information in the differentiation of cancerous tissues, although there is overlap in some cases

  20. Hepatic mitochondrial function analysis using needle liver biopsy samples.

    Directory of Open Access Journals (Sweden)

    Michael J J Chu

    Full Text Available BACKGROUNDS AND AIM: Current assessment of pre-operative liver function relies upon biochemical blood tests and histology but these only indirectly measure liver function. Mitochondrial function (MF analysis allows direct measurement of cellular metabolic function and may provide an additional index of hepatic health. Conventional MF analysis requires substantial tissue samples (>100 mg obtained at open surgery. Here we report a method to assess MF using <3 mg of tissue obtained by a Tru-cut® biopsy needle making it suitable for percutaneous application. METHODS: An 18G Bard® Max-core® biopsy instrument was used to collect samples. The optimal Tru-cut® sample weight, stability in ice-cold University of Wisconsin solution, reproducibility and protocol utility was initially evaluated in Wistar rat livers then confirmed in human samples. MF was measured in saponin-permeabilized samples using high-resolution respirometry. RESULTS: The average mass of a single rat and human liver Tru-cut® biopsy was 5.60±0.30 and 5.16±0.15 mg, respectively (mean; standard error of mean. Two milligram of sample was found the lowest feasible mass for the MF assay. Tissue MF declined after 1 hour of cold storage. Six replicate measurements within rats and humans (n = 6 each showed low coefficient of variation (<10% in measurements of State-III respiration, electron transport chain (ETC capacity and respiratory control ratio (RCR. Ischemic rat and human liver samples consistently showed lower State-III respiration, ETC capacity and RCR, compared to normal perfused liver samples. CONCLUSION: Consistent measurement of liver MF and detection of derangement in a disease state was successfully demonstrated using less than half the tissue from a single Tru-cut® biopsy. Using this technique outpatient assessment of liver MF is now feasible, providing a new assay for the evaluation of hepatic function.

  1. Are breast biopsies adequately funded? A process cost and revenue analysis

    International Nuclear Information System (INIS)

    Hahn, M.; Fischbach, E.; Fehm, T.

    2011-01-01

    Purpose: The objective of the study was to determine whether the various breast biopsy procedures specified in the S 3 guidelines are sensibly represented within the current German health system as considered from a cost evaluation perspective. Materials and Methods: This prospectively designed multicenter study analyzed 221 breast biopsies at 7 institutions from 04/2006 to 01/2007. Core needle biopsies, vacuum-assisted biopsies and surgical open biopsies under sonographic or mammographic guidance were evaluated. During an analysis of process costs, the individual process steps were recorded in diagrammatic form and assigned to the true consumption of resources. The actual resource consumption costs were entered. A process-related breakeven analysis was conducted to check whether the reimbursement of individual biopsy types covers the costs. Results: Only sonographically guided core needle biopsy and surgical open biopsy are adequately reimbursed in the current German health system. All other breast biopsies indicate a negative profit margin. The principal reasons for underfunding are found in the area of reimbursement of investment and non-personnel costs. Conclusion: The reimbursement of breast biopsies must be improved in order to guarantee nationwide care of the population using the breast biopsy methods recommended in the S 3 guidelines and to avoid disincentives with respect to breast biopsy indications. (orig.)

  2. Liquid biopsy for brain tumors

    Science.gov (United States)

    Shankar, Ganesh M.; Balaj, Leonora; Stott, Shannon L.; Nahed, Brian; Carter, Bob S.

    2018-01-01

    Introduction Minimally invasive methods will augment the clinical approach for establishing the diagnosis or monitoring treatment response of central nervous system tumors. Liquid biopsy by blood or cerebrospinal fluid sampling holds promise in this regard. Areas covered In this literature review, the authors highlight recent studies describing the analysis of circulating tumor cells, cell free nucleic acids, and extracellular vesicles as strategies to accomplish liquid biopsy in glioblastoma and metastatic tumors. The authors then discuss the continued efforts to improve signal detection, standardize the liquid biopsy handling and preparation, develop platforms for clinical application, and establish a role for liquid biopsies in personalized medicine. Expert commentary As the technologies used to analyze these biomarkers continue to evolve, we propose that there is a future potential to precisely diagnose and monitor treatment response with liquid biopsies. PMID:28875730

  3. Minimal invasive biopsy results of 'uncertain malignant potential' in digital mammography screening. High prevalence but also high predictive value for malignancy

    International Nuclear Information System (INIS)

    Weigel, S.; Heindel, W.; Universitaetsklinikum Muenster; Decker, T.; Universitaetsklinikum Muenster; Korsching, E.; Biesheuvel, C.; Woestmann, A.; Boecker, W.; Hungermann, D.; Roterberg, K.; Tio, J.

    2011-01-01

    Purpose: To evaluate the rate, the histological spectrum and the positive predictive value (PPV) for malignancy of minimally invasive biopsies with 'uncertain malignant potential (B3)' in digital mammography screening. Methods and Materials: Consecutive data of 37 178 participants of one digital unit of the German screening program were included. Results: The B 3 rate was 15.1 % (148/979). The frequencies of lesion subtypes were as follows: atypical epithelial proliferation of ductal type (AEPDT) 35.1 % (52/148), radial scar (RS) 28.4 % (42/148), papillary lesions (PAP) 20.3 % (30/148), lobular carcinoma in situ 8.8 % (13/148), flat epithelial atypia 5.4 % (8/148), and mucocele-like lesions 2.0 % (3/148). The PPV for malignancy in surgical excisions was overall 0.28 (25/91); in detail 0.40 (19/47) for AEPDT, 0.20 (5/25) for RS, 0.08 (1/12) for PAP. Conclusion: Despite a higher B 3 rate of minimally invasive biopsies with 'uncertain malignant potential' in digital screening, the benign surgical biopsy rate is not disproportionally increased compared with analog screening programs. Together with defined management protocols, this results in an increased cancer detection rate per screening participant with surgical excision. (orig.)

  4. A comparison of diagnostic performance of vacuum-assisted biopsy and core needle biopsy for breast microcalcification: a systematic review and meta-analysis.

    Science.gov (United States)

    Huang, Xu Chen; Hu, Xu Hua; Wang, Xiao Ran; Zhou, Chao Xi; Wang, Fei Fei; Yang, Shan; Wang, Gui Ying

    2018-03-16

    Core needle biopsy (CNB) and vacuum-assisted biopsy (VAB) are both popularly used breast percutaneous biopsies. Both of them have become reliable alternatives to open surgical biopsy (OSB) for breast microcalcification (BM). It is controversial that which biopsy method is more accurate and safer for BM. Hence, we conducted this meta-analysis to compare the diagnostic performance between CNB and VAB for BM, aiming to find out the better method. Articles according with including and excluding criteria were collected from the databases, PubMed, Embase, and the Cochrane Library. Preset outcomes were abstracted and pooled to find out the potential advantages in CNB or VAB. Seven studies were identified and entered final meta-analysis from initially found 138 studies. The rate of ductal carcinoma in situ (DCIS) underestimation was significantly lower in VAB than CNB group [risk ratio (RR) = 1.83, 95% confidence interval (CI) 1.40 to 2.40, p < 0.001]. The microcalcification retrieval rate was significantly higher in VAB than CNB group (RR = 0.89, 95% CI 0.81 to 0.98, p = 0.02), while CNB owned a significantly lower complication rate than VAB (RR = 0.18, 95% CI 0.03 to 0.93, p = 0.04). The atypical ductal hyperplasia (ADH) underestimation rates were not compared for the limited number of studies reporting this outcome. Compared with CNB, VAB shows better diagnostic performance in DCIS underestimation rate and microcalcification retrieval rate. However, CNB shows a significantly lower complication rate. More studies are needed to verify these findings.

  5. Magnetic resonance imaging-guided biopsies may improve diagnosis in biopsy-naive men with suspicion of prostate cancer

    DEFF Research Database (Denmark)

    Winther, Mads Dochedahl; Balslev, Ingegerd; Boesen, Lars

    2017-01-01

    INTRODUCTION: The purpose of this pilot study was to investigate whether a short prostate biparametric magnetic resonance imaging (bp-MRI) protocol provides a valuable diagnostic addition for biopsy guidance in biopsy-naive men with a suspicion of prostate cancer (PCa). METHODS: A total of 62...... biopsy-naive patients referred to a systematic transrectal ultrasound biopsy (TRUS-bx) due to suspicion of PCa were prospectively enrolled. Bp-MRI was performed before biopsy. All lesions were scored according to the modified Prostate Imaging Reporting and Data System (PI-RADS) version 2. All patients...

  6. Tumor containing fragment number influences immunohistochemistry positive rate of HER2 in biopsy specimens of gastric cancer.

    Science.gov (United States)

    Xu, Chen; Liu, Yalan; Ge, Xiaowen; Jiang, Dongxian; Zhang, Ying; Ji, Yuan; Hou, Jun; Huang, Jie; Su, Jieakesu; Zeng, Haiying; Qin, Jing; Hou, Yingyong

    2017-05-26

    HER2 assessment in biopsy specimens of gastric cancer (GC) is challenging because of the intratumoral heterogeneity. False negative results may be get because of limited biopsy material. The aim of this study is to explore how tumor-containing fragment number and biopsy specimen number affect HER2 immunohistochemistry (IHC) positive rate. Eight hundred and ninety biopsy specimens and 459 paired resected specimens were collected. IHC staining of HER2 was performed. HER2 IHC positive (scored 3+) rate was compared based on tumor-containing fragment number, biopsy specimen number, average size and tumor tissue proportion of tumor-containing fragments. The positive predictability of biopsy specimens to resected specimens was analyzed based on tumor fragment number. HER2 IHC positive rates were 2.0, 3.5, 7.0, 13.2, 17.1, and 15.9% when tumor fragment numbers were 1, 2, 3, 4, 5 and 6 respectively. The rate rose with the increase of tumor fragment number (P = 0.004). ROC curve analysis showed that biopsy specimens exhibited positive predictability when tumor fragment number reached 3, but showed better performance when the number was ≥4 (P fragment number reached 4, no statistic differences were reached in either HER2 IHC positive rate or positive predictability with further increase of the number (P > 0.05). HER2 IHC positive rate was not associated with biopsy number (P = 0.127), average size of tumor fragments (P = 0.397), and tumor tissue proportion of tumor fragments (P = 0.825) directly. The number of tumor-containing fragments influences HER2 IHC positive (scored 3+) rate. Greater than or equal to 4 (≥4) tumor fragments give better results in the positive rate as well as positive predictability. We recommend the number of tumor containing fragments be described in the HER2 IHC pathology reports for clinical reference in endoscopic biopsy specimens of GC.

  7. Transjugular liver core biopsy: indications, results, and complications; Transjugulaere Leberstanzbiopsie: Indikationen, Ergebnisse, Komplikationen

    Energy Technology Data Exchange (ETDEWEB)

    Dinkel, H.P.; Wittchen, K.; Hoppe, H.; Triller, J. [Inst. fuer Diagnostische Radiologie, Inselspital, Univ. Bern (Switzerland); Dufour, J.F. [Inst. fuer Klinische Pharmakologie, Inselspital, Univ. Bern (Switzerland); Zimmermann, A. [Inst. fuer Pathologie, Inselspital, Univ. Bern (Switzerland)

    2003-08-01

    Purpose: To evaluate benefit, feasibility, and frequency of complications with transjugular liver biopsy using a semi-automatic Tru-cut system. Materials and Methods: Eighty-five consecutive patients (57 males, 28 females) with various liver disorders (cirrhosis [30], hepatitis [12], acute hepatopathy [34], orthotopic liver transplantation [8], hepatocellular carcinoma [1]), coagulopathies (n=71) and/or ascites (n = 46) were referred to our department for a transjugular liver biopsy. Mean age was 48 {+-} 16 years (range 17 to 75 years). Success and complications were retrospectively evaluated from the radiology reports, pathology reports, and patient files. Success was defined as procuring a tissue specimen that enabled a definite histological diagnosis. The complications included thrombosis at the puncture site, hematoma, cardiac arrhythmia, capsular perforation, hemorrhage, and cardiac damage. Mortality included all deaths within 30 days after the procedure. Procedure-related mortality included all deaths related to the procedure. Results: The procedure was technically successful in 80 patients (94%) and unsuccessful in 5 patients (6%) due to a failed hepatic vein cannulation (1 patient with Budd Chiari syndrome and total liver vein occlusion, 4 patients with unsuitable anatomy). One biopsy pass was made in 22 patients, and two passes were made in 45 and three or more passes in 14 patients, all in a single session. The sample quality was judged by the pathologist as good in 71 of 80 patients (89%) and poor in 8 patients (10%). A diagnosis was not possible in 1 patient. Eight procedure-related complications occurred, which were classified according to the criteria of the society of interventional radiology (SIR) as minor in 5 (3 type A, 2 type B) and major in 3 (1 pneumothorax, type C, 1 nonfatal bleeding, type D, and 1 fatal bleeding, type F). Procedure-related mortality was 1%, overall mortality 15% (mostly due to progressive liver failure). (orig.) [German

  8. Biópsia mamária realizada pela técnica de biópsia helicoide: estudo experimental Breast biopsy performed by the helicoid biopsy technique: an experimental study

    Directory of Open Access Journals (Sweden)

    Eliel de Souza

    2010-12-01

    , using the SPSS software, version 13. RESULTS: the mean patient's age was 51.6 (±11.1 years old. The core biopsy showed 93.3% sensitivity, 100% specificity and 96.7% accuracy, and the helicoid biopsy showed 96.7% sensitivity, 100% specificity, and 98.3% accuracy. The comparison of tumor histology and biopsy fragments revealed a high degree of concordance in the diagnoses (Kappa equal to 0.9, with p<0.05. CONCLUSIONS: both methods provided a highly accurate histological diagnosis of the lesions. The results of the present study demonstrate that the helicoid biopsy is a reliable alternative for the preoperative diagnosis of breast lesions.

  9. The Incidence of Malignant Infiltration in the Biopsy Tract of Osteosarcoma

    Directory of Open Access Journals (Sweden)

    R Mohana

    2007-11-01

    Full Text Available Biopsy is a crucial step in the management of musculoskeletal sarcoma. The surgical approach to the biopsy site is important, as the tract must be removed en bloc with the tumour during limb sparing surgery so as to reduce the risk of local recurrence. The biopsy tracts of 26 osteosarcoma patients were evaluated histologically for tumour infiltration. Horizontal sections of 1 mm thickness with 2 cm radius from were evaluated from each excised biopsy tract. Five out of 26 cases (19.2% showed positive tumour infiltration. One case (3.85% had tumour infiltration in the pseudocapsule, two cases (7.69% had tumour infiltration into the muscle and two other cases (7.69% had tumour infiltration into the subcutaneous tissue. None had skin infiltration. We conclude that resection of the entire biopsy tract is indeed mandatory for surgical treatment of osteosarcoma.

  10. Stereotactic large-core needle breast biopsy: analysis of pain and discomfort related to the biopsy procedure

    International Nuclear Information System (INIS)

    Hemmer, Judith M.; Heesewijk, Hans P.M. van; Kelder, Johannes C.

    2008-01-01

    The purpose of this study was to determine the significance of variables such as duration of the procedure, type of breast tissue, number of passes, depth of the biopsies, underlying pathology, the operator performing the procedure, and their effect on women's perception of pain and discomfort during stereotactic large-core needle breast biopsy. One hundred and fifty consecutive patients with a non-palpable suspicious mammographic lesions were included. Between three and nine 14-gauge breast passes were taken using a prone stereotactic table. Following the biopsy procedure, patients were asked to complete a questionnaire. There was no discomfort in lying on the prone table. There is no relation between type of breast lesion and pain, underlying pathology and pain and performing operator and pain. The type of breast tissue is correlated with pain experienced from biopsy (P = 0.0001). We found out that patients with dense breast tissue complain of more pain from biopsy than patients with more involution of breast tissue. The depth of the biopsy correlates with pain from biopsy (P = 0.0028). Deep lesions are more painful than superficial ones. There is a correlation between the number of passes and pain in the neck (P = 0.0188) and shoulder (P = 0.0366). The duration of the procedure is correlated with pain experienced in the neck (P = 0.0116) but not with pain experienced from biopsy. (orig.)

  11. Percutaneous Biopsy of Retrobulbar Masses: Anatomical Considerations and MRI Guidance

    Energy Technology Data Exchange (ETDEWEB)

    Edalat, Faramarz, E-mail: faramarz.edalat@gmail.com; Cazzato, Roberto Luigi; Garnon, Julien; Tsoumakidou, Georgia [Nouvel Hôpital Civil (Hôpitaux Universitaires de Strasbourg, HUS), Department of Interventional Radiology (France); Avérous, Gerlinde [CHU Strasbourg Hautepierre, Department of Pathology (France); Caudrelier, Jean; Koch, Guillaume; Gangi, Afshin [Nouvel Hôpital Civil (Hôpitaux Universitaires de Strasbourg, HUS), Department of Interventional Radiology (France)

    2017-04-15

    PurposeObtaining adequate tissue from retrobulbar masses remains a challenge. To this end, a new method of retrobulbar mass biopsy using MRI guidance is presented.Materials and MethodsTwo patients (7- and 71-year-old male) with indeterminate retrobulbar masses underwent bioptic and cytological samplings using MR-compatible 18G and 20–22G needles, and multi-planar MR fluoroscopy. An inferior approach was taken to avoid injury to the optic nerve and ophthalmic arteries.ResultsThe two biopsies were completed without complication. The core biopsy resulted in a final diagnosis, whereas the cytological sampling was non-diagnostic.ConclusionPercutaneous MR-guided retrobulbar mass biopsy proved to be feasible and safe in the two cases described in this report.

  12. Scan-guided fine needle aspiration biopsy in malignant hepatic disease

    International Nuclear Information System (INIS)

    Johansen, P.; Svendsen, K.N.

    1978-01-01

    The method of scan-guided fine needle aspiration biopsy of the liver is described, and the diagnostic value of this combined method in the diagnosis of malignant hepatic disease is evaluated in 83 confirmed cases, showing a specificity of 100% and a sensitivity of 94%. The combined method is compared to liver scanning alone and to Menghini biopsy. Different methods for the diagnosis of malignant hepatic disease are discussed, and it is concluded that scan-guided fine needle aspiration biopsy has a diagnostic value only obtainable otherwise by a combination of liver scanning and biopsy during laparoscopy. Cytologic features in the two most common tumor types in this study, i.e., metastatic colonic adenocarcinoma and hepatocarcinoma, are presented along with a brief discussion of the specificity of the cytologic diagnosis of hepatocarcinoma

  13. Freehand biopsy guided by electromagnetic needle tracking

    DEFF Research Database (Denmark)

    Ewertsen, C; Nielsen, Marie Kristina Rue; Nielsen, M Bachmann

    2011-01-01

    To evaluate the overall accuracy and time spent on biopsy guided by electromagnetic needle tracking in a phantom compared with the standard technique of US-guided biopsy with an attached steering device. Furthermore, to evaluate off-plane biopsy guided by needle tracking.......To evaluate the overall accuracy and time spent on biopsy guided by electromagnetic needle tracking in a phantom compared with the standard technique of US-guided biopsy with an attached steering device. Furthermore, to evaluate off-plane biopsy guided by needle tracking....

  14. [Prostate cancer diagnostic by saturation randomized biopsy versus rigid targeted biopsy].

    Science.gov (United States)

    Defontaines, J; Salomon, L; Champy, C; Cholley, I; Chiaradia, M; de la Taille, A

    2017-12-01

    Optimal diagram teaming up randomized biopsy (BR) to targeted biopsy (BC) is still missing for the diagnostic of prostate cancer (CP). This study compares diagram of 6, 12 or 18 BR with or without BC rigid. Between January 2014 and May 2016, 120 patients had prostate biopsy BR and BC. Each patient had 18 BR and BC. Results compared sextant (6 BR), standard (12 BR) and saturation (18 BR) protocol with or without the adding of BC for the detection of CP. Rectal examination was normal, mean PSA at 8.99ng/mL and mean volume at 54cm 3 . It was first round for 48% of patients. Forty-four cancers were found by the group 18 BR+BC (control). The detection rate was respectively, for 6, 12 and 18 BR of 61%, 82% and 91%. The add of BC increased this detection of +27% for 6 BR+BC, +13% for 12 BR+BC and +9% for 18 BR+BC. BC found 70% of all CP. Nine percent of CP were missed by BR only. Significant CP (Gleason≥7) diagnostic was the same for 12 BR+BC and 18 BR+BC. The add of BC to BR increase the detection of CP by 10%. Twelve BR+BC is the optimal diagram for the diagnostic of CP finding 95% of CP and 97% of significant CP. 4. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  15. Imaging-histologic discordance at sonographically guided percutaneous biopsy of breast lesions

    International Nuclear Information System (INIS)

    Kim, Min Jung; Kim, Eun-Kyung; Park, Sun Young; Jung, Hae Kyoung; Park, Byeong-Woo; Kim, Haeryung; Oh, Ki Keun

    2008-01-01

    Objective: To determine the frequency of imaging-histologic discordance at percutaneous breast biopsy and to evaluate differences in clinical and radiologic findings between pathologically upgraded lesions and non-upgraded lesions. Materials and methods: From February 2000 to June 2005, we reviewed 386 cases that had suspicious imaging findings but yielded benign histology at US-core needle biopsy and that underwent subsequent excisional biopsy. In 74 of 386 cases, the benign histology at core needle biopsy could not provide a satisfactory explanation for the radiologically suspicious lesions. The clinical, radiologic and histologic findings were reviewed for those 74 cases that were classified as the upgrade group and the non-upgrade group after excisional biopsy. Results: The upgrade rate was 17.6% (95% confidence interval, 10.6-27.8%, 13 of 74 cases) revealed upgraded pathology at the subsequent excisional biopsy. Besides the size of masses, there were no statistically significant differences in imaging findings between the upgrade and non-upgrade groups at excisional biopsy. Conclusion: This upgrade rate of 17.6% suggests that excisional biopsy or re-biopsy is warranted in those cases presenting imaging-histologic discordance at US-guided core biopsy

  16. TU-CD-BRB-12: Radiogenomics of MRI-Guided Prostate Cancer Biopsy Habitats

    Energy Technology Data Exchange (ETDEWEB)

    Stoyanova, R; Lynne, C; Abraham, S; Patel, M; Jorda, M; Kryvenko, O; Ishkanian, A; Abramowitz, M; Pollack, A [University of Miami, Miami, FL (United States); Tachar, M; Erho, N; Buerki, C; Lam, L; Davicioni, E [GenomeDx Biosciences Inc., Vancouver, British Columbia (Canada)

    2015-06-15

    Purpose: Diagnostic prostate biopsies are subject to sampling bias. We hypothesize that quantitative imaging with multiparametric (MP)-MRI can more accurately direct targeted biopsies to index lesions associated with highest risk clinical and genomic features. Methods: Regionally distinct prostate habitats were delineated on MP-MRI (T2-weighted, perfusion and diffusion imaging). Directed biopsies were performed on 17 habitats from 6 patients using MRI-ultrasound fusion. Biopsy location was characterized with 52 radiographic features. Transcriptome-wide analysis of 1.4 million RNA probes was performed on RNA from each habitat. Genomics features with insignificant expression values (<0.25) and interquartile range <0.5 were filtered, leaving total of 212 genes. Correlation between imaging features, genes and a 22 feature genomic classifier (GC), developed as a prognostic assay for metastasis after radical prostatectomy was investigated. Results: High quality genomic data was derived from 17 (100%) biopsies. Using the 212 ‘unbiased’ genes, the samples clustered by patient origin in unsupervised analysis. When only prostate cancer related genomic features were used, hierarchical clustering revealed samples clustered by needle-biopsy Gleason score (GS). Similarly, principal component analysis of the imaging features, found the primary source of variance segregated the samples into high (≥7) and low (6) GS. Pearson’s correlation analysis of genes with significant expression showed two main patterns of gene expression clustering prostate peripheral and transitional zone MRI features. Two-way hierarchical clustering of GC with radiomics features resulted in the expected groupings of high and low expressed genes in this metastasis signature. Conclusions: MP-MRI-targeted diagnostic biopsies can potentially improve risk stratification by directing pathological and genomic analysis to clinically significant index lesions. As determinant lesions are more reliably

  17. Effects of muscular biopsy on the mechanics of running.

    Science.gov (United States)

    Morin, Jean-Benoit; Samozino, Pierre; Féasson, Léonard; Geyssant, André; Millet, Guillaume

    2009-01-01

    Muscle biopsy is a widely used technique in protocols aiming at studying physical capacities and fiber profiles of athletes, and muscular adaptations to exercise. Side effects of biopsy alone on physiological parameters have recently been pointed out, and we sought to determine whether a single biopsy had effects on the main stride mechanical parameters. Ten male runners performed 4-min runs before and after undergoing a biopsy of their left vastus lateralis muscle. Step frequency and duty factor were significantly higher after biopsy (2.86 +/- 0.14 vs. 2.82 +/- 0.15 Hz, and 0.77 +/- 0.04 vs. 0.75 +/- 0.05, respectively), whereas other factors were significantly lower: maximal vertical ground reaction force (1,601 +/- 240 vs. 1,643 +/- 230 N), loading rate (53.9 +/- 12.8 vs. 58.4 +/- 13.5 bw s(-1)), center of mass vertical displacement (0.056 +/- 0.008 vs. 0.058 +/- 0.008 m) and external mechanical work at each step (1.14 +/- 0.10 vs. 1.24 +/- 0.10 J kg(-1) step(-1)). These effects were observed on the left (biopsed) leg, but also on the right one for the external mechanical work, the duty factor and the maximal vertical ground reaction force, showing that a single biopsy had both ipsi- and contralateral effects on running mechanics.

  18. Sentinel lymph node biopsy in local recurrence of cutaneous melanoma

    International Nuclear Information System (INIS)

    Junqueira, G. Jr.; Bodanese, B.; Boff, M.F.; Espindola, M.B.; Haack, R.L.; Frigeri, C.D.L.

    2004-01-01

    Full text: Locally recurrent disease in patients with melanoma is usually defined as cutaneous or subcutaneous arising within 5 cm of the primary site after complete excision of the primary lesion. It may represent residual disease not excised with the primary tumor or the outgrowth of the satellite lesions, which are common with melanoma. Lymphatic mapping and sentinel lymph node (SLN) biopsy is highly accurate in staging nodal basins at risk of regional metastases in primary melanoma patients and identifies those who may benefit from earlier lymphadenectomy. Our purpose was to evaluate the efficacy of sentinel lymph node mapping and biopsy in local recurrence of cutaneous melanoma when the primary lesion was less than 1.0mm thick. Three patients with local recurrence of cutaneous melanoma underwent sentinel lymph node mapping and biopsy. All patients underwent preoperative lymphoscintigraphy to identify the lymphatic basin and the site of the sentinel node. All patients subsequently underwent intra-operative lymphatic mapping and selective lymph node biopsy with vital blue dye and hand-held gamma probe. Excised SLN were analysed by conventional histological staining (H and E) and immunohistochemical staining. In all patients the lymphatic mapping and sentinel lymph node biopsy was successful. The SLN biopsy was negative in two patients and positive in one who underwent therapeutic lymph node dissection. Our results indicate that the SLN mapping and biopsy is also possible in patients having local recurrence of cutaneous melanoma. Although long-term results are not available, early results are promising. (author)

  19. Changes in contact area characteristics of the ankle after a cartilage biopsy at the postero-medial rim of the talar dome.

    Science.gov (United States)

    Matricali, G A; Bartels, W; Labey, L; Dereymaeker, G Ph E; Luyten, F P; Vander Sloten, J

    2009-11-01

    Study the changes in local and generalized biomechanical characteristics of the ankle joint, associated with a well defined cartilage biopsy at the postero-medial rim of the talar dome, to evaluate its safety. Ten cadaver ankles were (sub-) physiologically loaded pre- and post-biopsy; in neutral position, 10 degrees of plantar-flexion (PF) and 10 degrees of dorsi-flexion (DF). Fuji film was used as transducer. Qualitatively, the coverage of the biopsy by the tibial plafond, and changes in the shape of the footprint were analyzed. Quantitatively, the pressure profile plot, normalized-tibio-talar contact area and the centroid position of pressure were examined. Results were reported as a mean for all specimens, and as individual values for every single specimen as well. Mean results did not show significant changes, but those of some single specimens did. The majority of those changes were in PF. Some occurred in N, and besides two exceptions none occurred in DF. Two specimens did not show any change. One specimen showed an isolated quantitative change. Seven specimens showed both qualitative and quantitative changes. However, all changes were of low-magnitude and contact stresses did not show any rebound effect. Although biopsies at the postero-medial rim of the talar dome did not induce on average significant changes in quantitative contact characteristics, few specimens did show some alterations. Currently, the investigated biopsy site seems safe, but long term follow-up studies in patients are needed for confirmation.

  20. Histological Spectrum of Idiopathic Noncirrhotic Portal Hypertension in Liver Biopsies From Dialysis Patients.

    Science.gov (United States)

    Lee, Hwajeong; Ainechi, Sanaz; Singh, Mandeep; Ells, Peter F; Sheehan, Christine E; Lin, Jingmei

    2015-09-01

    Liver biopsy is performed for various indications in dialysis patients. Being a less-common subset, the hepatic pathology in renal dialysis is not well documented. Idiopathic noncirrhotic portal hypertension (INCPH) is a clinical entity associated with unexplained portal hypertension and/or a spectrum of histopathological vascular changes in the liver. After encountering INCPH and vascular changes of INCPH in 2 renal dialysis patients, we sought to further investigate this noteworthy association. A random search for patients on hemodialysis or peritoneal dialysis with liver biopsy was performed. Hematoxylin and eosin, reticulin, trichrome, and CK7 stains were performed on formalin-fixed, paraffin-embedded tissue sections. Histopathological features were reviewed, and the results were correlated with clinical findings. In all, 13 liver biopsies were retrieved. The mean cumulative duration of dialysis was 50 months (range = 17 months to 11 years). All patients had multiple comorbidities. Indications for biopsy were a combination of abnormal liver function tests (6), portal hypertension (4), ascites (3), and possible cirrhosis (3). Two patients with portal hypertension underwent multiple liver biopsies for diagnostic purposes. All (100%) biopsies showed some histological features of INCPH, including narrowed portal venous lumen (9), increased portal vascular channels (8), shunt vessels (3), dilated sinusoids (9), regenerative nodule (5), and features of venous outflow obstruction (3). No cirrhosis was identified. Liver biopsies from patients on dialysis demonstrate histopathological vascular changes of INCPH. Some (31%) patients present with portal hypertension without cirrhosis. The histological changes may be reflective of underlying risk factors for INCPH in this group. © The Author(s) 2015.

  1. COMPARATIVE STUDY OF ENDOMETRIAL SAMPLING USING PIPELLE WITH HYSTEROSCOPIC-GUIDED BIOPSY

    Directory of Open Access Journals (Sweden)

    Nalina S

    2017-07-01

    Full Text Available BACKGROUND Hysteroscopic-guided biopsy is the gold standard for endometrial sampling, but it carries risk of general anaesthesia, infection and perforation, whereas Pipelle does not require anaesthesia or cervical dilatation and it allows outpatient and painless endometrial sampling. The aim of the study is to determine the reliability and accuracy of Pipelle aspiration in acquiring an adequate and representative endometrial sample and to compare its histopathology with hysteroscopic-directed biopsy. MATERIALS AND METHODS A prospective observational comparative study evaluating the role of Pipelle aspiration as an outpatient procedure in endometrial sampling of perimenopausal women with AUB. 150 perimenopausal women with clinical diagnosis of abnormal uterine bleeding were selected from the Gynaecology OPD of IOG, Chennai, between October 2014 and September 2015. They were subjected to endometrial sampling by Pipelle followed by hysteroscopic-directed biopsy. The efficacy of Pipelle was determined by correlating the histopathological results obtained from it and the hysteroscopic-directed biopsy. RESULTS The histopathology of the endometrium obtained using Pipelle’s curette showed a sensitivity of 93%, specificity of 90% in the detection of abnormal findings with PPV of 88% and NPV of 94%. However, accuracy of Pipelle is found to be less in the diagnosis of polyps and submucous fibroids with accuracy of nearing 100% when using hysteroscopy. CONCLUSION Pipelle endometrial sampling is convenient, easy, painless and safe in obtaining an adequate sample for histopathology with high sensitivity and specificity for endometrial pathologies and endometrial carcinoma.

  2. Gamma Imaging-Guided Minimally Invasive Breast Biopsy: Initial Clinical Experience.

    Science.gov (United States)

    Brem, Rachel F; Mehta, Anita K; Rapelyea, Jocelyn A; Akin, Esma A; Bazoberry, Adriana M; Velasco, Christel D

    2018-03-01

    The purpose of this study was to evaluate our initial experience with gamma imaging-guided vacuum-assisted breast biopsy in women with abnormal findings. A retrospective review of patients undergoing breast-specific gamma imaging (BSGI), also known as molecular breast imaging (MBI), between April 2011 and October 2015 found 117 nonpalpable mammographically and sonographically occult lesions for which gamma imaging-guided biopsies were recommended. Biopsy was performed with a 9-gauge vacuum-assisted device with subsequent placement of a titanium biopsy site marker. Medical records and pathologic findings were evaluated. Of the 117 biopsies recommended, 104 were successful and 13 were canceled. Of the 104 performed biopsies, 32 (30.8%) had abnormal pathologic findings. Of those 32 biopsies, nine (28.1%) found invasive cancers, six (18.8%) found ductal carcinoma in situ (DCIS), and 17 (53.1%) found high-risk lesions. Of the 17 high-risk lesions, there were three (17.6%) lobular carcinomas in situ, five (29.4%) atypical ductal hyperplasias, two (11.8%) atypical lobular hyperplasias, one (5.9%) flat epithelial atypia, and six (35.3%) papillomas. Two cases of atypical ductal hyperplasia were upgraded to DCIS at surgery. The overall cancer detection rate for gamma imaging-guided biopsy was 16.3%. In this study, gamma imaging-guided biopsy had a positive predictive value of total successful biopsies of 16.3% for cancer and 30.8% for cancer and high-risk lesions. Gamma imaging-guided biopsy is a viable approach to sampling BSGI-MBI-detected lesions without sonographic or mammographic correlate. Our results compare favorably to those reported for MRI-guided biopsy.

  3. Comparison of Battery-Powered and Manual Bone Biopsy Systems for Core Needle Biopsy of Sclerotic Bone Lesions.

    Science.gov (United States)

    Cohen, Micah G; McMahon, Colm J; Kung, Justin W; Wu, Jim S

    2016-05-01

    The purpose of this study was to compare manual and battery-powered bone biopsy systems for diagnostic yield and procedural factors during core needle biopsy of sclerotic bone lesions. A total of 155 consecutive CT-guided core needle biopsies of sclerotic bone lesions were performed at one institution from January 2006 to November 2014. Before March 2012, lesions were biopsied with manual bone drill systems. After March 2012, most biopsies were performed with a battery-powered system and either noncoaxial or coaxial biopsy needles. Diagnostic yield, crush artifact, CT procedure time, procedure radiation dose, conscious sedation dose, and complications were compared between the manual and battery-powered core needle biopsy systems by Fisher exact test and t test. One-way ANOVA was used for subgroup analysis of the two battery-powered systems for procedure time and radiation dose. The diagnostic yield for all sclerotic lesions was 60.0% (93/155) and was significantly higher with the battery-powered system (73.0% [27/37]) than with the manual systems (55.9% [66/118]) (p = 0.047). There was no significant difference between the two systems in terms of crush artifact, procedure time, radiation dose, conscious sedation administered, or complications. In subgroup analysis, the coaxial battery-powered biopsies had shorter procedure times (p = 0.01) and lower radiation doses (p = 0.002) than the coaxial manual systems, but the noncoaxial battery-powered biopsies had longer average procedure times and higher radiation doses than the coaxial manual systems. In biopsy of sclerotic bone lesions, use of a battery-powered bone drill system improves diagnostic yield over use of a manual system.

  4. The criteria for the decision of transrectal US-guided prostate biopsy: Can we reduce the number of unnecessary biopsies?

    International Nuclear Information System (INIS)

    Cho, Joon Hyung; Cho, Jae Ho; Ahn, Jay Hong; Chang, Jay Chun

    2001-01-01

    To establish the criteria which can safely reduce the number of unnecessary biopsies by comparing the transrectal ultrasonography (TRUS) findings, serum prostate-specific antigen (PSA), and prostate specific antigen density (PSAD) in the decision of criteria for the prostatic biopsy using TRUS. Two hundred and twenty patients underwent TRUS- guided prostate biopsy due to elevated PSA and/or focal nodule on TRUS were included. Sixty five (27.5%) patients were confirmed as prostate cancer, and remained 155 (70.5%) patients were reported as benign diseases including benign prostate hyperplasia. The sensitivity, specificity and accuracy of TRUS, PSA and PSAD were evaluated and the single criterion or the combination of the criteria which can safely reduce the unnecessary biopsies without missing prostatic cancer were investigated. The sensitivity, specificity and accuracy of TRUS, PSA (cut-off value, 4 ng/ml) and PSAD (cut-off level, 0.2 ng/ml/cm 3 ) were 78.5%/95.4%/95.4%/27.8%/51.6%/64/5%, 42.7%/64.5%/73.6%, respectively. PSAD cut-off level 0.2 ng/ml/cm 3 was the most excellent single criterion for the decision of prostatic biopsy and the number of unnecessary biopsies was 100 cases. But 3 cases of prostatic cancer which the PSAD level was below 0.2 ng/ml/cm 3 were included and in all these 3 cases, a focal nodule was detected on TRUS. Therefore, we applied these two criteria at once and the biopsies of 30 cases (13.6%) are unnecessary. With the single criterion, we could not obtain the satisfactory results but by the combinations of criteria (TRUS and PSAD), 30 (13.6%) cases are unnecessary biopsies without missing cancer. We think that the short term follow-up may be a substitute for the immediate when nodular lesion is suspicious on TRUS and serum PSAD level is below 0.2 ng/ml/cm 3 .

  5. Usefulness of the coaxial technique in US-guided breast core biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong Hyun; Lee, Jeong Hwa; Ha, Jeon Ju; Lee, Keon; Kim, Won Ho; Kwon, Jung Hyeok [Dongkang general hospital, Seoul (Korea, Republic of); Ham, Soo Youn [Ulsan Univ. Hospital, Ulsan (Korea, Republic of)

    1999-05-01

    To evaluate the usefulness of the coaxial technique in US-guided breast core biopsy. Using the coaxial technique, US-guided breast core biopsy was performed in 49 breast lesions (40 patients). Under US-guidance the 17-gauge, 13 cm long introducer needle was positioned proximal to the lesion. Once the needle was in place, the central trocar was removed and was replaced with the core biopsy needle. We used an 18-gauge, 16-cm-long core biopsy needle with a 17 mm specimen notch. Four to eight tissue specimens were obtained from each lesion, and the quality and quantity of specimens, procedure time, and complications and their rate were evaluated. For 48 of 49 lesions, specimens were adequate for histopathologic diagnosis, and the findings were as follows : six cases of invasive ductal carcinoma, one of ductal carcinoma in situ, 29 of fibrocystic disease, eight of fibroadenoma, two of chronic inflammation, and two of sclerosing lesion. In 12 lesions agreement between the pathologic results of needle core biopsy and surgical results was 100%. The procedure time was about 15 minutes and no significant complications were noted. In breast core biopsy, the coaxial technique is simple and time-saving, and compared with standard breast core biopsy, may also be less traumatic and decrease the potential risk of seeding the biopsy tract with malignant cells.

  6. Usefulness of the coaxial technique in US-guided breast core biopsy

    International Nuclear Information System (INIS)

    Kim, Dong Hyun; Lee, Jeong Hwa; Ha, Jeon Ju; Lee, Keon; Kim, Won Ho; Kwon, Jung Hyeok; Ham, Soo Youn

    1999-01-01

    To evaluate the usefulness of the coaxial technique in US-guided breast core biopsy. Using the coaxial technique, US-guided breast core biopsy was performed in 49 breast lesions (40 patients). Under US-guidance the 17-gauge, 13 cm long introducer needle was positioned proximal to the lesion. Once the needle was in place, the central trocar was removed and was replaced with the core biopsy needle. We used an 18-gauge, 16-cm-long core biopsy needle with a 17 mm specimen notch. Four to eight tissue specimens were obtained from each lesion, and the quality and quantity of specimens, procedure time, and complications and their rate were evaluated. For 48 of 49 lesions, specimens were adequate for histopathologic diagnosis, and the findings were as follows : six cases of invasive ductal carcinoma, one of ductal carcinoma in situ, 29 of fibrocystic disease, eight of fibroadenoma, two of chronic inflammation, and two of sclerosing lesion. In 12 lesions agreement between the pathologic results of needle core biopsy and surgical results was 100%. The procedure time was about 15 minutes and no significant complications were noted. In breast core biopsy, the coaxial technique is simple and time-saving, and compared with standard breast core biopsy, may also be less traumatic and decrease the potential risk of seeding the biopsy tract with malignant cells

  7. Breath-hold after forced expiration before removal of the biopsy needle decreased the rate of pneumothorax in CT-guided transthoracic lung biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Min, Lingfeng; Xu, Xingxiang [Subei People' s Hospital of Jiangsu Province, Clinical Medical School of Yangzhou University, Yangzhou 225001, Jiangsu (China); Song, Yong [Jinling Hospital, Nanjing University School of Medical, Nanjing 210002, Jiangsu (China); Issahar, Ben-Dov [Pulmonary Institute, Sheba Medical Center, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv (Israel); Wu, Jingtao; Zhang, Le; Huang, Qian [Subei People' s Hospital of Jiangsu Province, Clinical Medical School of Yangzhou University, Yangzhou 225001, Jiangsu (China); Chen, Mingxiang, E-mail: chenmx1129@126.com [Subei People' s Hospital of Jiangsu Province, Clinical Medical School of Yangzhou University, Yangzhou 225001, Jiangsu (China)

    2013-01-15

    Purpose: To assess the effect of a breath-hold after forced expiration on the rate of pneumothorax after computed tomography (CT)-guided transthoracic needle biopsy of pulmonary lesions. Materials and methods: Between January 2008 and December 2011, percutaneous CT-guided lung biopsy was performed in 440 patients. Two hundred and twenty-one biopsies were performed without (control group) and two hundred and nineteen biopsies were performed with (study group) the study maneuver – a breath-hold after forced expiratory approach. Multivariate analysis was performed between groups for risk factors for pneumothorax, including patient demographics, lesion characteristics, and biopsy technique. Results: A reduced number of pneumothoraces (18 [8.2%] vs 35 [15.8%]; P = 0.014) but no significant difference in rate of drainage catheter insertions (2 [0.9%] vs (4 [1.8%]; P = 0.418) were noted in the study group as compared with the control group. By logistic regression analysis, three factors significantly and independently affected the risk for pneumothorax including lesion size (transverse and longitudinal diameter), distance from pleura and utilizing or avoiding the breath-hold after deep expiration maneuver. Conclusion: Breath-holding after forced expiration before removal of the biopsy needle during the percutaneous CT-guided transthoracic lung biopsy almost halved the rate of overall pneumothorax. Small lesion size (longitudinal diameter) and the distance from pleura were also predictors of pneumothorax in our study.

  8. Breath-hold after forced expiration before removal of the biopsy needle decreased the rate of pneumothorax in CT-guided transthoracic lung biopsy

    International Nuclear Information System (INIS)

    Min, Lingfeng; Xu, Xingxiang; Song, Yong; Issahar, Ben-Dov; Wu, Jingtao; Zhang, Le; Huang, Qian; Chen, Mingxiang

    2013-01-01

    Purpose: To assess the effect of a breath-hold after forced expiration on the rate of pneumothorax after computed tomography (CT)-guided transthoracic needle biopsy of pulmonary lesions. Materials and methods: Between January 2008 and December 2011, percutaneous CT-guided lung biopsy was performed in 440 patients. Two hundred and twenty-one biopsies were performed without (control group) and two hundred and nineteen biopsies were performed with (study group) the study maneuver – a breath-hold after forced expiratory approach. Multivariate analysis was performed between groups for risk factors for pneumothorax, including patient demographics, lesion characteristics, and biopsy technique. Results: A reduced number of pneumothoraces (18 [8.2%] vs 35 [15.8%]; P = 0.014) but no significant difference in rate of drainage catheter insertions (2 [0.9%] vs (4 [1.8%]; P = 0.418) were noted in the study group as compared with the control group. By logistic regression analysis, three factors significantly and independently affected the risk for pneumothorax including lesion size (transverse and longitudinal diameter), distance from pleura and utilizing or avoiding the breath-hold after deep expiration maneuver. Conclusion: Breath-holding after forced expiration before removal of the biopsy needle during the percutaneous CT-guided transthoracic lung biopsy almost halved the rate of overall pneumothorax. Small lesion size (longitudinal diameter) and the distance from pleura were also predictors of pneumothorax in our study

  9. Analysis of cosmetic results and complications in patients with Stage I and II breast cancer treated by biopsy and irradiation

    International Nuclear Information System (INIS)

    Clarke, D.; Martinez, A.; Cox, R.S.

    1983-01-01

    Between May, 1973 and December, 1980, 78 Stage I and II breast carcinomas in 76 patients were treated by biopsy and radiotherapy with curative intent. With a maximum follow-up of 10 years, a minimum of 2 1/2 years and a median follow-up of 3 1/2 years, a loco-regional control rate of 97% was obtained. Cosmetic results and treatment complications were studied. Patient characteristics, tumor size, excisional biopsy technique, axillary staging procedure and radiotherapy techniques were analyzed and all found to be important factors affecting cosmesis and complications. The most common complications included transient breast edema observed in 51% of patients, breast fibrosis (usually mild) seen in 23% of the population, axillary hematoma or seroma formation in 15%, mild arm edema in 14% and basilic vein thrombosis in 10% of patients. The causes of these and other less frequent complications are discussed. The overall cosmetic result was excellent in 78%, satisfactory in 18% and unsatisfactory in 4% of patients. Recommendations for improving cosmetic results and minimizing complications are made

  10. Percutaneous Native Renal Biopsy Adequacy: A Successful Interdepartmental Quality Improvement Activity

    Directory of Open Access Journals (Sweden)

    Laurette Geldenhuys

    2015-03-01

    Full Text Available Background: An adequate renal biopsy is essential for diagnosis and treatment of medical renal disease. Objective: We evaluated two initiatives to improve adequacy of renal biopsy samples at our centre. Design: Retrospective determination of renal biopsy adequacy. Setting: Queen Elizabeth II Health Sciences Centre. Patients: Patients undergoing medical renal biopsies. Measurements: Renal biopsy adequacy. Methods: The first initiative was to restrict the performance of biopsies to a smaller group of radiologists and to include a comment on biopsy adequacy in every pathology report. The second initiative was to introduce on-site adequacy assessment by a medical laboratory technologist. Native renal and allograft biopsy adequacies were calculated for three periods: 1 baseline, October 2005 to September 2006; 2 after implementation of the first initiative, January 2007 to September 2011; and 3 after implementation of the second initiative, October 2011 to September 2012. A subset of native renal biopsies was examined to determine if there was a relationship between adequacy and number of passes. Results: The percentages of adequate native renal biopsies during the first, second, and third periods were 31%, 72% and 90%, respectively. This represents a significant increase (40%, p < 0.0001 in adequacy following the first initiative, and another significant increase (18%, p = 0.0003 following the second initiative. The percentages of adequate renal allograft biopsies during the first, second, and third periods were 75%, 56% and 69%, respectively. These changes in adequacy were not statistically significant. In the subset of native renal biopsies examined, a biopsy comprising more than three cores was not associated with increase in adequacy. Limitations: The most important limitation is the lack of generally accepted and applied adequacy criteria limiting generalizability of our findings. Conclusions: Restricting the performance of biopsies to

  11. [The role of percutaneous renal biopsy in kidney transplant].

    Science.gov (United States)

    Manfro, R C; Lee, J Y; Lewgoy, J; Edelweiss, M I; Gonçalves, L F; Prompt, C A

    1994-01-01

    Percutaneous renal biopsy (PRB) is an useful tool for diagnostic and therapeutic orientation in renal transplantation. PURPOSE--To evaluate the current role of PRB in post-transplant acute renal dysfunction (ARD) of renal allografts. METHODS--Sixty-five renal transplant patients were submitted to 95 valid renal biopsies with no major complications. RESULTS--There was disagreement between the clinical and the pathological diagnosis in 28 occasions (29.5%). In 36 cases (37.9%) the results of the pathological examination led to a modification in patient's management. These modifications were most commonly the avoidance or witholding of a steroid pulse (8 cases); nephrectomy of the renal allograft (8 cases); witholding or decrease of cyclosporine dosage (6 cases); giving a steroid pulse (5 cases) and giving antibiotics to treat acute pyelonephritis in 4 cases. The use of kidneys from cadaveric donors was significantly associated with an increased number of biopsies (p renal biopsy is still an indispensable method to the management of ARD in renal transplant patients.

  12. No need for biopsies

    DEFF Research Database (Denmark)

    Gjødsbøl, Kristine; Skindersoe, Mette E; Christensen, Jens Jørgen

    2011-01-01

    The aim of the study was to compare three sampling techniques used in routine diagnostics to identify the microbiota in chronic venous leg ulcers. A total of 46 patients with persisting venous leg ulcers were included in the study. At inclusion, swab, biopsy and filter paper pad samples were...... collected. After 4 weeks, additional biopsy and filter paper pad samples were collected. Bacteria were isolated and identified at species level by standard methods. The most common bacterial species detected was Staphylococcus aureus found in 89% of the ulcers. No methicillin-resistant S. aureus isolates...... species present in chronic wounds, thus avoiding complications during and after biopsy sampling....

  13. Histological diagnosis of ultrasound-visible breast lesions by large core needle biopsy

    International Nuclear Information System (INIS)

    Sanchis-Querol, E.; Valeros, O.; Collado, A.; Gimenez, J.; Yanguas, C.

    1999-01-01

    We present our experience in the histological diagnosis of breast lesions using ultrasound-guided large core needle biopsy (LCNB), assessing its utility as an alternative to excisional biopsy. We have studied retrospectively a series of 146 cases involving the performance of LCNB. The results were comparable with those of FNAB in 59 cases and with those of surgical aspiration biopsy in 105. Of the 113 lesions identified as malignant by percutaneous large core needle aspiration biopsy, 96 were resected. Surgical aspiration biopsy agreed with LCNB in 100% of cases. Of the 33 lesions identified as benign by LCNB, surgical biopsy detected malignancy in 5. The results obtained establish a specificity for LCNB of 100% and a sensitivity of 96%, both of which are superior to the values for FNAB. Thus, this technique can be considered valid for preoperative diagnosis. LCNB is useful in the preoperative diagnosis of breast lesions, making FNAB and surgical biopsy unnecessary. Moreover, it constitutes a significant change in the management of patients with malignant or undetermined breast lesions. (Author) 8 refs

  14. Computed tomography-guided percutaneous biopsy of pancreatic masses using pneumodissection

    Directory of Open Access Journals (Sweden)

    Chiang Jeng Tyng

    2013-06-01

    Full Text Available Objective To describe the technique of computed tomography-guided percutaneous biopsy of pancreatic tumors with pneumodissection. Materials and Methods In the period from June 2011 to May 2012, seven computed tomography-guided percutaneous biopsies of pancreatic tumors utilizing pneumodissection were performed in the authors' institution. All the procedures were performed with an automatic biopsy gun and coaxial system with Tru-core needles. The biopsy specimens were histologically assessed. Results In all the cases the pancreatic mass could not be directly approached by computed tomography without passing through major organs and structures. The injection of air allowed the displacement of adjacent structures and creation of a safe coaxial needle pathway toward the lesion. Biopsy was successfully performed in all the cases, yielding appropriate specimens for pathological analysis. Conclusion Pneumodissection is a safe, inexpensive and technically easy approach to perform percutaneous biopsy in selected cases where direct access to the pancreatic tumor is not feasible.

  15. Computed tomography-guided percutaneous biopsy of pancreatic masses using pneumodissection

    International Nuclear Information System (INIS)

    Tyng, Chiang Jeng; Bitencourt, Almir Galvao Vieira; Almeida, Maria Fernanda Arruda; Barbosa, Paula Nicole Vieira; Martins, Eduardo Bruno Lobato; Junior, Joao Paulo Kawaoka Matushita; Chojniak, Rubens; Coimbra, Felipe Jose Fernandez

    2013-01-01

    Objective: to describe the technique of computed tomography-guided percutaneous biopsy of pancreatic tumors with pneumodissection. Materials and methods: in the period from June 2011 to May 2012, seven computed tomography guided percutaneous biopsies of pancreatic tumors utilizing pneumodissection were performed in the authors' institution. All the procedures were performed with an automatic biopsy gun and coaxial system with Tru-core needles. The biopsy specimens were histologically assessed. Results: in all the cases the pancreatic mass could not be directly approached by computed tomography without passing through major organs and structures. The injection of air allowed the displacement of adjacent structures and creation of a safe coaxial needle pathway toward the lesion. Biopsy was successfully performed in all the cases, yielding appropriate specimens for pathological analysis. Conclusion: Pneumodissection is a safe, inexpensive and technically easy approach to perform percutaneous biopsy in selected cases where direct access to the pancreatic tumor is not feasible. (author)

  16. Non-specific Inflammatory Disease Showed Abnormal FDG Uptake in Lower Extremities

    International Nuclear Information System (INIS)

    Chun, Kyung Ah; Kong, Eun Jung; Cho, Ihn Ho; Hong, Young Hoon; Lee, Choong Ki

    2008-01-01

    Including malignancy, various disease can show abnormal uptake in bone marrow. 1,2) We report a case of non-specific inflammatory FDG uptake in bone marrow mimicking malignancy. A 35-year old woman with fever of unknown origin (FUO) underwent 18 F-FDG PET/CT to find out fever focus and unknown malignancy. 18 F-FDG was injected and imaged 1hr after injection with Discovery ST (GE, USA). 18 F-FDG PET/CT whole body image showed abnormal uptake in lower extremities. MRI and biopsy was also done in the sites of abnormal uptake. PET and MRI suspect malignancy, but biopsy result was non-specific inflammatory process. The patient was improved her clinical condition after antibiotics therapy

  17. Diagnosis of BK viral nephropathy in the renal allograft biopsy: role of fluorescence in situ hybridization.

    Science.gov (United States)

    Wang, Zhen; Portier, Bryce P; Hu, Bo; Chiesa-Vottero, Andres; Myles, Jonathan; Procop, Gary W; Tubbs, Raymond R

    2012-09-01

    Early recognition of BK viral nephropathy is essential for successful management. Our aim in this study was to evaluate a novel fluorescence in situ hybridization (FISH) assay for detection of BK virus in renal transplant biopsies in the context of standard detection methods. Renal allograft biopsies (n = 108) were analyzed via H&E, immunohistochemistry (IHC) for simian virus 40, and FISH for BK virus. BK virus was detected in 16 (14.8%) cases by H&E, 13 (12%) cases by IHC, 18 (16.6%) cases by FISH, and 19 (17.6%) cases by real-time PCR; 24 of 108 showed a discrepancy in ≥1 testing modalities. Comparison of H&E, IHC, and FISH showed no statistical difference in detection of BK virus. However, performing comparisons between the different tissue-based assays in the context of plasma or urine real-time PCR results showed significant improvement in detection of BK by FISH over H&E (P = 0.02) but not IHC (P = 0.07). This novel FISH-based approach for BK virus identification in renal allograft biopsy tissue mirrored real-time PCR results and showed superior performance to detection of inclusions by H&E. Therefore, use of FISH for BK virus detection in the setting of renal allograft biopsy is a useful and sensitive detection method and could be adopted in any laboratory that currently performs FISH analysis. Copyright © 2012 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.

  18. CT-guided biopsy: diagnostic relevance, therapeutic consequences and economic aspects

    International Nuclear Information System (INIS)

    Schwarzenberg, H.; Mueller-Huelsbeck, S.; Link, J.; Brossmann, J.; Fahl, M.; Quirin, A.; Heller, M.

    1996-01-01

    Purpose: To evaluate the diagnostic and clinical relevance and therapeutic consequences of CT-guided biopsy with regard to economic aspects. Methods: 213 CT-guided biopsies in 190 were evaluated. All information regarding patient referral, reason for request, body region, underlying diagnosis, and clinical consequences were registered over a period of 22.2±9.4 month. Results: Patient referral to biopsy was mainly from the departments of surgery, internal medicine, and radiotherapy with the question of tumor and metastasis. Less than 5% of biopsies were performed in outpatients. Main regions were the lung (39%), the abdomen (35%), and the skeleton (11%). Biopsy and surgical histology corresponded in 73%. Largest diagnosis groups were benign unspecific tissues or other benign lesions in 24%. As a result of CTP no further procedures necessary in 22.5%. Follow-up studies or conservative treatment were indicated in 11.3%. Surgical procedures were needed in only 15.5%. There was only one complication requiring therapy. Conclusion: CT-guided biopsy is a safe procedure, which helps to avoid unnecessary cost-intensive diagnostics and surgical treatment. If CTP is performed early and in outpatients residence time in the hospital is reduced and thus money is saved. (orig.) [de

  19. Discordance between location of positive cores in biopsy and location of positive surgical margin following radical prostatectomy.

    Science.gov (United States)

    Kim, Ji Won; Park, Hyoung Keun; Kim, Hyeong Gon; Ham, Dong Yeub; Paick, Sung Hyun; Lho, Yong Soo; Choi, Woo Suk

    2015-10-01

    We compared location of positive cores in biopsy and location of positive surgical margin (PSM) following radical prostatectomy. This retrospective analysis included patients who were diagnosed as prostate cancer by standard 12-core transrectal ultrasonography guided prostate biopsy, and who have PSM after radical prostatectomy. After exclusion of number of biopsy cores location data, 46 patients with PSM were identified. Locations of PSM in pathologic specimen were reported as 6 difference sites (apex, base and lateral in both sides). Discordance of biopsy result and PSM was defined when no positive cores in biopsy was identified at the location of PSM. Most common location of PSM were right apex (n=21) and left apex (n=15). Multiple PSM was reported in 21 specimens (45.7%). In 32 specimens (69.6%) with PSM, one or more concordant positive biopsy cores were identified, but 14 specimens (28%) had no concordant biopsy cores at PSM location. When discordant rate was separated by locations of PSM, right apex PSM had highest rate of discordant (38%). The discordant group had significantly lower prostate volume and lower number of positive cores in biopsy than concordant group. This study showed that one fourth of PSM occurred at location where tumor was not detected at biopsy and that apex PSM had highest rate of discordant. Careful dissection to avoid PSM should be performed in every location, including where tumor was not identified in biopsy.

  20. Epidemiology of biopsy-proven glomerulonephritis in Queensland adults.

    Science.gov (United States)

    Jegatheesan, Dev; Nath, Karthik; Reyaldeen, Reza; Sivasuthan, Goutham; John, George T; Francis, Leo; Rajmokan, Mohana; Ranganathan, Dwarakanathan

    2016-01-01

    There is a paucity of data pertaining to the incidence of biopsy-proven glomerulonephritis (GN) in Australia. This retrospective study aims to review the data from all adult native renal biopsies performed in the state of Queensland from 2002 to 2011--comparing results with centres from across the world. Pathology reports of 3697 adult native kidney biopsies were reviewed, of which 2048 had GN diagnoses. Age, gender, clinical indication and histopathology findings were compared. The average age at biopsy was 48 ± 17 years. Male preponderance was noted overall (∼60%), with lupus nephritis being the only individual GN with female predilection. The average rate of biopsy was 12.04 per hundred thousand people per year (php/yr). Nephrotic and nephritic syndromes comprised approximately 75% of all clinical indications that lead to GN diagnoses. IgA nephropathy (1.41 php/yr) was the most common primary GN followed by focal segmental glomerulosclerosis (1.02 php/yr) and crescentic GN (0.73 php/yr). Diabetic nephropathy (0.84 php/yr), lupus nephritis (0.69 php/yr) and amyloidosis (0.19 php/yr) were the most commonly identified secondary GN. IgA nephropathy is the predominant primary GN in Queensland, and nephrotic syndrome the most common indication for a renal biopsy. While crescentic GN incidence has significantly increased with time, focal segmental glomerulosclerosis incidence has not shown any trend. Incidence of GN overall appears to increase with age. The annual rate of biopsy in this study appears lower than previously published in an Australian population. © 2015 Asian Pacific Society of Nephrology.

  1. Digital imaging improves upright stereotactic core biopsy of mammographic microcalcifications

    International Nuclear Information System (INIS)

    Whitlock, J.P.L.; Evans, A.J.; Burrell, H.C.; Pinder, S.E.; Ellis, I.O.; Blamey, R.W.; Wilson, A.R.M.

    2000-01-01

    AIM: This comparative study was carried out to assess the effect of using digital images compared to conventional film-screen mammography on the accuracy of core biopsy of microcalcifications using upright stereotactic equipment. MATERIALS AND METHODS: The biopsy results from a consecutive series of 104 upright stereotactic 14-gauge core biopsies performed with conventional X-ray (Group A) were compared with 40 biopsies carried out using stereotaxis with digital imaging (Group B). In all cases specimen radiography was performed and analysed for the presence of calcifications. Pathological correlation was then carried out with needle and surgical histology. RESULTS: The use of digital add-on equipment increased the radiographic calcification retrieval rate from 55 to 85% (P < 0.005). The absolute sensitivity of core biopsy in pure ductal carcinoma in situ (DCIS) cases rose from 34 to 69% (P < 0.03), with the complete sensitivity increasing from 52 to 94% (P < 0.005). For DCIS with or without an invasive component the absolute sensitivity rose from 41 to 67% (P = 0.052), while the complete sensitivity was 59% before and 86% after the introduction of digital imaging (P < 0.04). CONCLUSION: Digital equipment improves the performance of upright stereotactic core biopsy of microcalcifications, giving a significantly increased success rate in accurately obtaining calcifications. This leads to an improvement in absolute and complete sensitivity of core biopsy when diagnosing DCIS. Whitlock, J.P.L. (2000)

  2. Evaluation of a robotic technique for transrectal MRI-guided prostate biopsies

    Energy Technology Data Exchange (ETDEWEB)

    Schouten, Martijn G. [Radboud University Nijmegen Medical Centre, Department of Radiology, Nijmegen (Netherlands); University Medical Centre Nijmegen, Department of Radiology, Nijmegen (Netherlands); Bomers, Joyce G.R.; Yakar, Derya; Huisman, Henkjan; Bosboom, Dennis; Scheenen, Tom W.J.; Fuetterer, Jurgen J. [Radboud University Nijmegen Medical Centre, Department of Radiology, Nijmegen (Netherlands); Rothgang, Eva [Pattern Recognition Lab, Friedrich-Alexander-University of Erlangen-Nuremberg, Erlangen (Germany); Center for Applied Medical Imaging, Siemens Corporate Research (Germany); Center for Applied Medical Imaging, Siemens Corporate Research, Baltimore, MD (United States); Misra, Sarthak [University of Twente, MIRA-Institute of Biomedical Technology and Technical Medicine, Enschede (Netherlands)

    2012-02-15

    To evaluate the accuracy and speed of a novel robotic technique as an aid to perform magnetic resonance image (MRI)-guided prostate biopsies on patients with cancer suspicious regions. A pneumatic controlled MR-compatible manipulator with 5 degrees of freedom was developed in-house to guide biopsies under real-time imaging. From 13 consecutive biopsy procedures, the targeting error, biopsy error and target displacement were calculated to evaluate the accuracy. The time was recorded to evaluate manipulation and procedure time. The robotic and manual techniques demonstrated comparable results regarding mean targeting error (5.7 vs 5.8 mm, respectively) and mean target displacement (6.6 vs 6.0 mm, respectively). The mean biopsy error was larger (6.5 vs 4.4 mm) when using the robotic technique, although not significant. Mean procedure and manipulation time were 76 min and 6 min, respectively using the robotic technique and 61 and 8 min with the manual technique. Although comparable results regarding accuracy and speed were found, the extended technical effort of the robotic technique make the manual technique - currently - more suitable to perform MRI-guided biopsies. Furthermore, this study provided a better insight in displacement of the target during in vivo biopsy procedures. (orig.)

  3. Evaluation of a robotic technique for transrectal MRI-guided prostate biopsies

    International Nuclear Information System (INIS)

    Schouten, Martijn G.; Bomers, Joyce G.R.; Yakar, Derya; Huisman, Henkjan; Bosboom, Dennis; Scheenen, Tom W.J.; Fuetterer, Jurgen J.; Rothgang, Eva; Misra, Sarthak

    2012-01-01

    To evaluate the accuracy and speed of a novel robotic technique as an aid to perform magnetic resonance image (MRI)-guided prostate biopsies on patients with cancer suspicious regions. A pneumatic controlled MR-compatible manipulator with 5 degrees of freedom was developed in-house to guide biopsies under real-time imaging. From 13 consecutive biopsy procedures, the targeting error, biopsy error and target displacement were calculated to evaluate the accuracy. The time was recorded to evaluate manipulation and procedure time. The robotic and manual techniques demonstrated comparable results regarding mean targeting error (5.7 vs 5.8 mm, respectively) and mean target displacement (6.6 vs 6.0 mm, respectively). The mean biopsy error was larger (6.5 vs 4.4 mm) when using the robotic technique, although not significant. Mean procedure and manipulation time were 76 min and 6 min, respectively using the robotic technique and 61 and 8 min with the manual technique. Although comparable results regarding accuracy and speed were found, the extended technical effort of the robotic technique make the manual technique - currently - more suitable to perform MRI-guided biopsies. Furthermore, this study provided a better insight in displacement of the target during in vivo biopsy procedures. (orig.)

  4. Three cases of systemic amyloidosis successfully diagnosed by subcutaneous fat tissue biopsy of the hip

    Directory of Open Access Journals (Sweden)

    Arahata M

    2016-08-01

    Full Text Available Masahisa Arahata,1 Shigeru Shimadoi,1 Satosi Yamatani,1 Shin-ichi Hayashi,2 Shigeharu Miwa,2 Hidesaku Asakura,3 Shinji Nakao4 1Department of Internal Medicine, Nanto Municipal Hospital, Nanto, 2Department of Diagnostic Pathology, Graduate School of Medicine and Pharmaceutical Sciences, University of Toyama, Toyama, 3Department of Internal Medicine (III, 4Department of Cellular Transplantation Biology, Division of Cancer Medicine, Graduate School of Medical Science, Kanazawa University, Kanazawa, Japan Abstract: Fine-needle aspiration biopsy of the abdominal fat pad is considered to be a minimally invasive procedure for diagnosing systemic amyloidosis. However, this procedure is sometimes difficult and can be dangerous for elderly patients whose abdominal fat layer is thin because of malnutrition. In such cases, alternative diagnostic methods are required. We report three elderly patients with heart failure complicated by malnutrition. In all cases, electrocardiogram showed low voltage in the limb leads and a pseudoinfarct pattern in the chest leads, and echocardiography showed left ventricular wall thickening with granular sparkling appearance. These patients were suspected of having amyloid cardiomyopathy but could not undergo myocardial biopsies because of their poor conditions. After failed attempts at biopsy of the abdominal fat pad or the other organs, subcutaneous fat tissue biopsy over the hip led to the diagnosis of systemic amyloidosis with cardiomyopathy. The resultant diagnosis guided us to choose the appropriate treatment for the patients. This article illustrates that subcutaneous fat tissue biopsy of the hip could be a useful procedure for diagnosing systemic amyloidosis in elderly patients, particularly when a fat tissue biopsy of the abdomen is associated with a high risk of complications because of malnutrition. Keywords: systemic amyloidosis, amyloid cardiomyopathy, fine-needle aspiration biopsy, subcutaneous fat tissue, hip

  5. Histopathologic Review of Previously Negative Prostatic Core Needle Biopsies following a New Diagnosis of Adenocarcinoma of the Prostate by Core Needle Biopsies: Implications for Quality Assurance Programs

    Directory of Open Access Journals (Sweden)

    Jay Patel

    2008-01-01

    Full Text Available Programs for quality assurance are increasingly important in surgical pathology. Many quality assurance (QA techniques for surgical pathology were adopted from procedures introduced in cytopathology. Surgical pathology specimens have diminished in size such that the majority of diagnostic biopsies of prostatic lesions are now core needle biopsies. These specimens raise issues similar to those of cytology specimens, including concerns regarding adequacy and the representative nature of the biopsy. Due to sample size, some neoplasms may not be diagnosed on initial biopsy, raising concerns regarding false negative results. Cytopathologists have instituted QA procedures including review of all previously negative slides received within five years prior to the new diagnosis of high grade squamous intraepithelial lesion or gynecologic malignancy. No such requirement exists in surgical pathology for review of core biopsies. The Department of Pathology at the University of Utah instituted a QA policy requiring review of prior negative prostatic needle biopsies following a new diagnosis of prostatic adenocarcinoma. We reviewed five years of QA records of prostate needle biopsy review. During this time, nine hundred and fifty-eight core biopsy sets were performed. Two hundred and ninety-five of these contained at least one biopsy with a diagnosis of adenocarcinoma. Two hundred and eight patients had a prior set of prostatic needle biopsies with a diagnosis of adenocarcinoma. The remaining 87 had prior biopsies with either a diagnosis of prostatic intraepithelial neoplasia (23, small atypical acinar proliferation (21 or no evidence of malignancy (43. QA review of these 87 cases revealed two biopsies which revealed foci of adenocarcinoma. Both had been initially diagnosed as no evidence of malignancy. The false negative rate for core biopsy was 0.68%. In an additional twenty-one cases, microscopic foci of atypical small acinar proliferations were found in

  6. CT fluoroscopy-guided core needle biopsy of anterior mediastinal masses.

    Science.gov (United States)

    Iguchi, T; Hiraki, T; Matsui, Y; Fujiwara, H; Sakurai, J; Masaoka, Y; Uka, M; Tanaka, T; Gobara, H; Kanazawa, S

    2018-02-01

    To retrospectively evaluate the safety, diagnostic yield, and risk factors of diagnostic failure of computed tomography (CT) fluoroscopy-guided biopsies of anterior mediastinal masses. Biopsy procedures and results of anterior mediastinal masses in 71 patients (32 women/39 men; mean [±standard deviation] age, 53.8±20.0years; range, 14-88years) were analyzed. Final diagnoses were based on surgical outcomes, imaging findings, or clinical follow-up findings. The biopsy results were compared with the final diagnosis, and the biopsy procedures grouped by pathologic findings into diagnostic success and failure groups. Multiple putative risk factors for diagnostic failure were then assessed. Seventy-one biopsies (71 masses; mean size, 67.5±27.3mm; range 8.6-128.2mm) were analyzed. We identified 17 grade 1 and one grade 2 adverse events (25.4% overall) according to the National Cancer Institute Common Terminology Criteria for Adverse Events version 4.0. Sixty-nine biopsies (97.2%) provided samples fit for pathologic analysis. Diagnostic failure was found for eight (11.3%) masses; the 63 masses diagnosed successfully included thymic carcinoma (n=17), lung cancer (n=14), thymoma (n=12), malignant lymphoma (n=11), germ cell tumor (n=3), and others (n=6). Using a thinner needle (i.e., a 20-gauge needle) was the sole significant risk factor for diagnostic failure (P=0.039). CT fluoroscopy-guided biopsy of anterior mediastinal masses was safe and had a high diagnostic yield; however, using a thinner biopsy needle significantly increased the risk of a failed diagnosis. Copyright © 2017 Éditions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.

  7. Unusual presentation and inconclusive biopsy render fibroadenoma ...

    African Journals Online (AJOL)

    Two young, nonlactating, nulliparous women presented with acutely painful breast masses. Sonographic features showed mixed echogenic masses. Core biopsies were not diagnostic, and surgical excision revealed infarcted fibroadenomas in both cases. Although fibroadenomas are common, they do not commonly infarct, ...

  8. Transthoracic needle biopsy: factors effecting risk of pneumothorax

    International Nuclear Information System (INIS)

    Topal, Ugur; Ediz, Buelent

    2003-01-01

    Objective: to evaluate the factors that could effect the risk of pneumothorax in patients undergoing transthoracic biopsy. Material and methods: variables that could increase the risk of pneumothorax were evaluated in 453 CT-guided transthoracic biopsies. Factors were evaluated in two groups: (1) lesion related (presence of emphysema around the lesion, lesion depth, cavitation, presence of fissure/atelectasis and pleural tag in the needle trajectory); and (2) procedure related (biopsy type, needle size, number of passages, level of experience of the operator). All variables were analysed by χ 2 test and multivariate logistic regression statistics. Results: pneumothorax was developed in 85 (18.8%) out of 453 procedures. A chest tube was inserted in ten (11.7%) of them. Variables that were significantly associated with an increased risk of pneumothorax were depth of the lesion (P<0.001) and severity of the emphysema (P<0.01). Conclusion: the length of the lung parenchyma traversed during the biopsy is the predominant risk factor for pneumothorax in patients undergoing CT-guided transthoracic biopsy. The risk of pneumothorax was also increased with the severity of the emphysema around the lesion

  9. Health-economic evaluation of magnetic resonance imaging before biopsy for diagnosis of prostate cancer

    International Nuclear Information System (INIS)

    Stadlbauer, A.; Salomonowitz, E.; Bernt, R.; Plas, E.; Strunk, G.; Eberhardt, K.

    2011-01-01

    The aim of this study was the health-economic analysis of MR imaging in the diagnostics of suspicious prostate carcinoma (PCa) before execution of a first biopsy. The health-economic analysis included four steps: modeling, determination of probabilities, evaluation, and sensitivity analyses. We performed an effectiveness analysis from the patient perspective as well as a cost-effectiveness and a cost-utility analysis from the health insurance perspective for Austria and Germany. The effectiveness and cost-effectiveness analysis used a hypothetical cohort of 100 000 patients. The result parameters were number of biopsies, number of detected PCa, and monetary costs. For the cost-efficiency analysis, the result parameters, quality-adjusted life years (QALYs) and costs, were calculated for an individual patient. The efficiency analysis showed that MRI before a first biopsy can prevent ca. 64 000 unnecessary biopsies/ 100 000 patients. The diagnostic efficiency was higher by a factor of 1.7. Due to MRI, eight PCas were additionally detected. From a health insurance perspective, MRI was not cost-effective. Extra costs of ca. 42 m. Euro per 100 000 patients and of 650 Euro per prevented biopsy were calculated. The costs per detected PCa were increased by 1395 Euro. The attainable QALYs were a little higher for the MRI alternative, which was therefore not dominated. Our results do not permit a clear recommendation for or against the application of MRI in the diagnostics of PCa. From the patient perspective, it is to be endorsed due to the higher medical efficiency. However, it is connected with higher health insurance costs. (orig.)

  10. Stereotaxic percutaneous core biopsy versus surgical biopsy of nonpalpable breast lesions using a standard mammographic table with an add-on device

    International Nuclear Information System (INIS)

    Levin, M.F.; Papoff, W.J.; Doan, L.; Eliasziw, M.

    2001-01-01

    To determine the accuracy of using a regular mammographic table with an add-on device for biopsy of nonpalpable breast lesions in women in a community hospital setting. During a 3-year period, 70 consenting women (39-80 years of age) with a nonpalpable mammographically suspicious lesion on routine screening mammography underwent 14-gauge automated percutaneous core biopsies, immediate needle localization and lumpectomy. The needle and surgical biopsy results were independently classified into 1 of 5 categories: cancer, fibroadenomal fibrocystic change, normal or other. The procedure was well tolerated, and all core specimens yielded adequate tissue for pathologic evaluation. There were 3 episodes of vasovagal reaction. There was complete agreement in histologic findings in 64 cases (91%), including 22 of 24 cancers (92%). The overall agreement for categorizing lesions was 91% (k 0.88), and there was 97% agreement (k = 0.94) for the classification of cancer versus benign lesion. The results are similar to those of studies performed with dedicated prone equipment. Stereotaxic core biopsies can be done safely and accurately in a community hospital setting with relatively inexpensive nondedicated mammographic equipment. (author)

  11. Stereotaxic percutaneous core biopsy versus surgical biopsy of nonpalpable breast lesions using a standard mammographic table with an add-on device

    Energy Technology Data Exchange (ETDEWEB)

    Levin, M.F.; Papoff, W.J.; Doan, L.; Eliasziw, M. [St. Thomas-Elgin General Hospital, St. Thomas, Ontario (Canada)

    2001-02-01

    To determine the accuracy of using a regular mammographic table with an add-on device for biopsy of nonpalpable breast lesions in women in a community hospital setting. During a 3-year period, 70 consenting women (39-80 years of age) with a nonpalpable mammographically suspicious lesion on routine screening mammography underwent 14-gauge automated percutaneous core biopsies, immediate needle localization and lumpectomy. The needle and surgical biopsy results were independently classified into 1 of 5 categories: cancer, fibroadenomal fibrocystic change, normal or other. The procedure was well tolerated, and all core specimens yielded adequate tissue for pathologic evaluation. There were 3 episodes of vasovagal reaction. There was complete agreement in histologic findings in 64 cases (91%), including 22 of 24 cancers (92%). The overall agreement for categorizing lesions was 91% (k 0.88), and there was 97% agreement (k = 0.94) for the classification of cancer versus benign lesion. The results are similar to those of studies performed with dedicated prone equipment. Stereotaxic core biopsies can be done safely and accurately in a community hospital setting with relatively inexpensive nondedicated mammographic equipment. (author)

  12. Accuracy of CT-guided biopsies in 158 patients with thoracic spinal lesions

    Energy Technology Data Exchange (ETDEWEB)

    Hao, D.J.; He, B.R.; Liu, T.J.; Zhao, Q.P. (Dept. of Spinal Surgery, Xian Red Cross Hospital, Xian Shaanxi (China)), email: zqpddn1@gmail.com; Sun, H.H. (Dept. of Orthopaedic, Tangdu Hospital, Fourth Military Medical Univ., Xian Shaanxi (China)); Jiang, Y.H. (Dept. of Radiology, Xian Red Cross Hospital, Xian Shaanxi (China))

    2011-11-15

    Background. Inconsistent accuracies of CT-guided thoracic spinal biopsies have been reported in previous studies. Purpose. To determine the accuracy of CT-guided thoracic spinal biopsy, to compare the results with those previously reported, and to determine if there are any factors that influence the accuracy of CT-guided thoracic spinal biopsy. Material and Methods. In total, 158 consecutive CT-guided percutaneous thoracic spine procedures (performed at the Dept. of Spinal Surgery, Xian Red Cross Hospital between April 2000 and July 2010) were reviewed. The 158 lesions were categorized by location and radiographic features. Pathological and clinical follow-up were used to determine accuracy. Results. The diagnostic accuracy of CT-guided thoracic spinal biopsy was 90.5% overall. Biopsy of metastatic bone disease (98.2%) was significantly more accurate than biopsies of primary tumors (80.9%) and of hematological malignancies (47.0%) (P < 0.05 and P < 0.005, respectively). The diagnostic accuracy of CT-guided thoracic spinal biopsy was significantly higher for the lower thoracic spine (97.6%) than for the middle (90.0%) or upper thoracic spine (80.4%) (P < 0.05 and P < 0.025, respectively). The diagnostic accuracy was significantly higher for lytic lesions (96.4%) than for sclerotic lesions (81.3%) (P < 0.010). The accuracy of biopsies performed using the transpedicular approach (91.0%) was not significantly different from that of biopsies performed using posterolateral approaches (91.5%) (0.25 < P < 0.5). Conclusion. Percutaneous CT-guided thoracic spinal biopsy is a viable alternative to open surgical biopsy. The diagnostic accuracy was not affected by any of the variables except for lesion level, histology, and radiographic features

  13. Accuracy of CT-guided biopsies in 158 patients with thoracic spinal lesions

    International Nuclear Information System (INIS)

    Hao, D.J.; He, B.R.; Liu, T.J.; Zhao, Q.P.; Sun, H.H.; Jiang, Y.H.

    2011-01-01

    Background. Inconsistent accuracies of CT-guided thoracic spinal biopsies have been reported in previous studies. Purpose. To determine the accuracy of CT-guided thoracic spinal biopsy, to compare the results with those previously reported, and to determine if there are any factors that influence the accuracy of CT-guided thoracic spinal biopsy. Material and Methods. In total, 158 consecutive CT-guided percutaneous thoracic spine procedures (performed at the Dept. of Spinal Surgery, Xian Red Cross Hospital between April 2000 and July 2010) were reviewed. The 158 lesions were categorized by location and radiographic features. Pathological and clinical follow-up were used to determine accuracy. Results. The diagnostic accuracy of CT-guided thoracic spinal biopsy was 90.5% overall. Biopsy of metastatic bone disease (98.2%) was significantly more accurate than biopsies of primary tumors (80.9%) and of hematological malignancies (47.0%) (P < 0.05 and P < 0.005, respectively). The diagnostic accuracy of CT-guided thoracic spinal biopsy was significantly higher for the lower thoracic spine (97.6%) than for the middle (90.0%) or upper thoracic spine (80.4%) (P < 0.05 and P < 0.025, respectively). The diagnostic accuracy was significantly higher for lytic lesions (96.4%) than for sclerotic lesions (81.3%) (P < 0.010). The accuracy of biopsies performed using the transpedicular approach (91.0%) was not significantly different from that of biopsies performed using posterolateral approaches (91.5%) (0.25 < P < 0.5). Conclusion. Percutaneous CT-guided thoracic spinal biopsy is a viable alternative to open surgical biopsy. The diagnostic accuracy was not affected by any of the variables except for lesion level, histology, and radiographic features

  14. Surface staining of small intestinal biopsies

    DEFF Research Database (Denmark)

    Poulsen, Steen Seier

    1977-01-01

    Small intestinal biopsies are most often by routine examined under a stereo-microscope, prior to embedding for histological examination. This is done in order to get a view of the appearance of the mucosal pattern, especially villus configuration. The distinctness of the surface pattern however......, is improved considerably if the biopsies are stained with Alcian Green and/or PAS before they are examined. In the present paper a detailed description is given of staining of small intestinal biopsies as whole mounts. The difference between the unstained and the stained biopsies is illustrated by a few...

  15. Needle muscle biopsy and its application

    Directory of Open Access Journals (Sweden)

    Meng-long CHEN

    2015-07-01

    Full Text Available Needle muscle biopsy is a straightforward and reliable minimally-invasive technique. During the past century, the needle biopsy can provide adequate samples and the technique has gradually gained wider acceptance. Compared with open biopsy, needle biopsy is less traumatic, with low rate of complications, and is suitable for the identifications and evaluations of muscular dystrophy, inflammatory myopathies and systemic diseases involving muscles, specially for infants and young children. Domestic insiders should be encouraged to apply this technique. DOI: 10.3969/j.issn.1672-6731.2015.06.003 

  16. 20 CFR 718.106 - Autopsy; biopsy.

    Science.gov (United States)

    2010-04-01

    ... 20 Employees' Benefits 3 2010-04-01 2010-04-01 false Autopsy; biopsy. 718.106 Section 718.106... PNEUMOCONIOSIS Criteria for the Development of Medical Evidence § 718.106 Autopsy; biopsy. (a) A report of an autopsy or biopsy submitted in connection with a claim shall include a detailed gross macroscopic and...

  17. A template for a clinico-pathological audit of medical liver biopsies.

    Science.gov (United States)

    Colling, Richard; Fryer, Eve; Cobbold, Jeremy; Collier, Jane; Collantes, Elena; Wang, Lai Mun; Hubscher, Stefan; Wyatt, Judith; Fleming, Kenneth

    2015-11-01

    With changing indications for performing medical liver biopsies, we aimed to develop a tool to allow pathologists to evaluate the current usefulness, value and impact of their medical liver biopsy service. We designed and piloted a questionnaire-based clinico-pathological audit for medical liver biopsies. The audit tool was simple to implement and provided useful information about our service. Hepatologists felt that 96% of reports were clinically useful. 56% of biopsies confirmed clinical diagnoses, 46% helped differentiate between diagnoses and 42% were able to exclude possible diagnoses. 74% resulted in a change of management and 27% of liver biopsies resulted in a diagnosis which was not clinically suspected. We demonstrate the usefulness of an audit tool in providing evidence of the value of the liver pathology service in a large UK regional centre. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  18. Are concurrent systematic cores needed at the time of targeted biopsy in patients with prior negative prostate biopsies?

    Science.gov (United States)

    Albisinni, S; Aoun, F; Noel, A; El Rassy, E; Lemort, M; Paesmans, M; van Velthoven, R; Roumeguère, T; Peltier, A

    2018-01-01

    MRI-guided targeted biopsies are advised in patients who have undergone an initial series of negative systematic biopsies, in whom prostate cancer (PCa) suspicion remains elevated. The aim of the study was to evaluate whether, in men with prior negative prostate biopsies, systematic cores are also warranted at the time of an MRI-targeted repeat biopsy. We enrolled patients with prior negative biopsy undergoing real time MRI/TRUS fusion guided prostate biopsy at our institute between 2014 and 2016. Patients with at least one index lesion on multiparametric MRI were included. All eligible patients underwent both systematic random biopsies (12-14 cores) and targeted biopsies (2-4 cores). The study included 74 men with a median age of 65 years, PSA level of 9.27ng/mL, and prostatic volume of 45ml. The overall PCa detection rate and the clinically significant cancer detection rate were 56.7% and 39.2%, respectively. Targeted cores demonstrated similar clinically significant PCa detection rate compared to systematic cores (33.8% vs. 28.4%, P=0.38) with significantly less tissue sampling. Indeed, a combination approach was significantly superior to a targeted-only in overall PCa detection (+16.7% overall detection rate, P=0.007). Although differences in clinically significant PCa detection were statistically non-significant (P=0.13), a combination approach did allow detecting 7 extra clinically significant PCas (+13.8%). In patients with elevated PSA and prior negative biopsies, concurrent systematic sampling may be needed at the time of targeted biopsy in order to maximize PCa detection rate. Larger studies are needed to validate our findings. 4. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  19. The Utility of Endoscopic Biopsies in Patients with Normal Upper Endoscopy

    Directory of Open Access Journals (Sweden)

    Anouar Teriaky

    2016-01-01

    Full Text Available Background and Aims. Upper endoscopy is a valuable tool in the workup of gastrointestinal (GI complaints. The purpose of this study is to determine cost and yield of taking biopsies in a normal upper GI tract. Methods. This is a retrospective study where all upper GI biopsies were identified between May 2012 and April 2013, at a tertiary care center. Clinical, procedural, and pathology reports were reviewed to identify patient demographics, procedure information, and pathology diagnosis. Results. Biopsies of the upper GI tract were taken in 1297 patients with normal upper endoscopies. In patients with normal upper endoscopy, 22% of esophageal, 44% of gastric, and 12% of duodenal biopsies were abnormal. The most frequent abnormality was reflux esophagitis in 16% of esophageal biopsies, chronic gastritis in 23% of gastric biopsies, and increased intraepithelial lymphocytes in 6% of duodenal biopsies. The additional cost for taking biopsies in a normal upper GI tract for a diagnosis of eosinophilic esophagitis was $2963 Canadian (CAD, H. pylori associated gastritis was $1404 CAD, and celiac disease was $3024 CAD. Conclusions. The yield of biopsy in normal upper endoscopy varied with location, but the additional expense can be costly and should be tailored to appropriate clinical situations.

  20. IS WAITING THE HARDEST PART? A CRITICAL STUDY OF THE EXPERIENCE OF WOMEN AWAITING BREAST BIOPSY RESULTS.

    Science.gov (United States)

    Hodgkinson, T; Govender, C; Rayne, S

    2017-06-01

    Most previous research efforts have focused on the psychological effects of receiving a cancer diagnosis rather than the period of waiting for definitive Results. Early detection of cancer is directly linked to successful treatment regimes, yet these procedures evoke significant anxiety in patients. The long wait for medical test Results in state health institutions, with one of the possible outcomes being a cancer diagnosis, means that the days of waiting can induce emotional distress before the diagnosis has even been given. Eight research collaborators were invited to, in their own voice, shed light on their individual experiences while waiting for their biopsy Results to gain an understanding of the experiences of each collaborator by letting her tell her story and to explore the possibility of shared experience between collaborators. Research collaborators at a local, government hospital kept a journal for the two-week waiting period for their biopsy Results. Shortly before receiving their Results, they took part in a short semi-structured interview to inquire about their waiting. The theoretical framework used for data interpretation is critical theory focusing on the structures within society and healthcare systems that impact on the experience of waiting. The undercurrent of critical commentary about the roles of the gender, economic, political and cultural factors that contribute to the screening experience for women in South Africa helps to shed light on the complex forces at play within the procedures. The Results indicate that for some women waiting provokes significant psychological stress which manifests in multiple psychological processes including the psychological bracing phenomenon, denial, suppression and negation of their emotional experience all perpetuated by the structures of power within the health care system. More understanding of the psychological experience of awaiting a cancer diagnosis is required and there is an important place for

  1. Risk factor analysis of pulmonary hemorrhage complicating CT-guided lung biopsy in coaxial and non-coaxial core biopsy techniques in 650 patients

    Energy Technology Data Exchange (ETDEWEB)

    Nour-Eldin, Nour-Eldin A., E-mail: nour410@hotmail.com [Institute for Diagnostic and Interventional Radiology, Johan Wolfgang Goethe – University Hospital, Theodor-Stern-Kai 7, 60590 Frankfurt am Main (Germany); Diagnostic and Interventional Radiology Department, Cairo University Hospital, Cairo (Egypt); Alsubhi, Mohammed [Institute for Diagnostic and Interventional Radiology, Johan Wolfgang Goethe – University Hospital, Theodor-Stern-Kai 7, 60590 Frankfurt am Main (Germany); Naguib, Nagy N. [Institute for Diagnostic and Interventional Radiology, Johan Wolfgang Goethe – University Hospital, Theodor-Stern-Kai 7, 60590 Frankfurt am Main (Germany); Diagnostic and Interventional Radiology Department, Alexandria University Hospital, Alexandria (Egypt); Lehnert, Thomas; Emam, Ahmed; Beeres, Martin; Bodelle, Boris; Koitka, Karen; Vogl, Thomas J.; Jacobi, Volkmar [Institute for Diagnostic and Interventional Radiology, Johan Wolfgang Goethe – University Hospital, Theodor-Stern-Kai 7, 60590 Frankfurt am Main (Germany)

    2014-10-15

    Purpose: To evaluate the risk factors involved in the development of pulmonary hemorrhage complicating CT-guided biopsy of pulmonary lesions in coaxial and non-coaxial techniques. Materials and methods: Retrospective study included CT-guided percutaneous lung biopsies in 650 consecutive patients (407 males, 243 females; mean age 54.6 years, SD: 5.2) from November 2008 to June 2013. Patients were classified according to lung biopsy technique in coaxial group (318 lesions) and non-coaxial group (332 lesions). Exclusion criteria for biopsy were: lesions <5 mm in diameter, uncorrectable coagulopathy, positive-pressure ventilation, severe respiratory compromise, pulmonary arterial hypertension or refusal of the procedure. Risk factors for pulmonary hemorrhage complicating lung biopsy were classified into: (a) patient's related risk factors, (b) lesion's related risk factors and (d) technical risk factors. Radiological assessments were performed by two radiologists in consensus. Mann–Whitney U test and Fisher's exact tests for statistical analysis. p values <0.05 were considered statistically significant. Results: Incidence of pulmonary hemorrhage was 19.6% (65/332) in non-coaxial group and 22.3% (71/318) in coaxial group. The difference in incidence between both groups was statistically insignificant (p = 0.27). Hemoptysis developed in 5.4% (18/332) and in 6.3% (20/318) in the non-coaxial and coaxial groups respectively. Traversing pulmonary vessels in the needle biopsy track was a significant risk factor of the development pulmonary hemorrhage (incidence: 55.4% (36/65, p = 0.0003) in the non-coaxial group and 57.7% (41/71, p = 0.0013) in coaxial group). Other significant risk factors included: lesions of less than 2 cm (p value of 0.01 and 0.02 in non-coaxial and coaxial groups respectively), basal and middle zonal lesions in comparison to upper zonal lung lesions (p = 0.002 and 0.03 in non-coaxial and coaxial groups respectively), increased lesion

  2. Risk factor analysis of pulmonary hemorrhage complicating CT-guided lung biopsy in coaxial and non-coaxial core biopsy techniques in 650 patients

    International Nuclear Information System (INIS)

    Nour-Eldin, Nour-Eldin A.; Alsubhi, Mohammed; Naguib, Nagy N.; Lehnert, Thomas; Emam, Ahmed; Beeres, Martin; Bodelle, Boris; Koitka, Karen; Vogl, Thomas J.; Jacobi, Volkmar

    2014-01-01

    Purpose: To evaluate the risk factors involved in the development of pulmonary hemorrhage complicating CT-guided biopsy of pulmonary lesions in coaxial and non-coaxial techniques. Materials and methods: Retrospective study included CT-guided percutaneous lung biopsies in 650 consecutive patients (407 males, 243 females; mean age 54.6 years, SD: 5.2) from November 2008 to June 2013. Patients were classified according to lung biopsy technique in coaxial group (318 lesions) and non-coaxial group (332 lesions). Exclusion criteria for biopsy were: lesions <5 mm in diameter, uncorrectable coagulopathy, positive-pressure ventilation, severe respiratory compromise, pulmonary arterial hypertension or refusal of the procedure. Risk factors for pulmonary hemorrhage complicating lung biopsy were classified into: (a) patient's related risk factors, (b) lesion's related risk factors and (d) technical risk factors. Radiological assessments were performed by two radiologists in consensus. Mann–Whitney U test and Fisher's exact tests for statistical analysis. p values <0.05 were considered statistically significant. Results: Incidence of pulmonary hemorrhage was 19.6% (65/332) in non-coaxial group and 22.3% (71/318) in coaxial group. The difference in incidence between both groups was statistically insignificant (p = 0.27). Hemoptysis developed in 5.4% (18/332) and in 6.3% (20/318) in the non-coaxial and coaxial groups respectively. Traversing pulmonary vessels in the needle biopsy track was a significant risk factor of the development pulmonary hemorrhage (incidence: 55.4% (36/65, p = 0.0003) in the non-coaxial group and 57.7% (41/71, p = 0.0013) in coaxial group). Other significant risk factors included: lesions of less than 2 cm (p value of 0.01 and 0.02 in non-coaxial and coaxial groups respectively), basal and middle zonal lesions in comparison to upper zonal lung lesions (p = 0.002 and 0.03 in non-coaxial and coaxial groups respectively), increased lesion

  3. Upright stereotactic vacuum-assisted needle biopsy of suspicious breast microcalcification

    International Nuclear Information System (INIS)

    Sim, L. S. J.; Kei, P. L.

    2008-01-01

    Full text: Stereotactic core needle biopsy is a useful technique for evaluation of suspicious breast microcalcifications. Thf development of the 11-G vacuum-assisted biopsy system offers another method of minimally invasive biopsy carried out on a conventional mammography unit. We evaluate its usefulness, efficacy and safety in Asian women.. Vacuum-assisted biopsy was carried out through the lateral approach using an add-on stereotactic device attached to a mammography unit. One hundred and five lesions were sampled in 97 patients. Excisional biopsy was subsequently Carried out for diagnosis of atypical ductal hyperplasia or carcinoma in high-risk patients. Patients with benign diagnosis underwent mammographic follow up. The technical success rate was 97%. An average of 13.5 tissue cores were retrieved for each lesion. The histopathological result obtained from mammotome was benign in 84.8% and malignant in 15.2%. The benign microcalcifications were predominantly fibrocystic change (n = 42)| whereas the malignant microcalcifications included ductal carcinoma in situ (n = 15) and invasive carcinoma (n = 1). Twenty-two patients underwent subsequent open surgical biopsy but no underestimation of disease was seen. Only two patients had vasovagal syncope and three others felt unwell during the biopsy. Nine patients had small haema-1 tomas, which resolved spontaneously. Vacuum-assisted biopsy carried out on an upright stereotactic mammography] unit is a safe and effective method for evaluation of suspicious microcalcifications.

  4. Eosinophils in biopsy specimens of lichen sclerosus: a not uncommon finding.

    Science.gov (United States)

    Lester, Elizabeth B; Swick, Brian L

    2015-01-01

    Evolving lesions of lichen sclerosus (LS) pose a diagnostic challenge owing to an absence of classic findings of epidermal atrophy, dermal sclerosis, a band-like lymphocytic infiltrate and the presence of eosinophils. Retrospective specimens of LS were reviewed. Demographic information, biopsy vs. excision and the following histopathological characteristics were noted: presence and number of eosinophils, epidermal hyperplasia, spongiosis, early/transitional LS, well-developed LS and coexisting squamous cell carcinoma (SCC). Linear regression analysis was performed. The data consisted of 66 biopsies (36 male [M], 30 female [F]), from 53 individuals (33M, 20F), including 57 genital and 9 extragenital biopsies. Seven biopsies showed SCC, 28 showed epidermal hyperplasia and 14 exhibited spongiosis. Thirty-five specimens were early/transitional LS and commonly exhibited epidermal hyperplasia (57%), epidermotropism of lymphocytes (97%) and basement membrane thickening (97%). Thirty-five biopsies (53%) contained eosinophils (23 early/transitional lesions). Male gender (p = 0.074) was associated with increased eosinophils. The presence of SCC (p = 0.014) was a significant predictors of eosinophil number. Epidermal hyperplasia, epidermotropism of lymphocytes and basement membrane thickening are helpful features in identifying early LS. Eosinophils are not an uncommon finding in LS and are most common in male genital lesions and in LS associated with SCC. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  5. Low grade urothelial carcinoma mimicking basal cell hyperplasia and transitional metaplasia in needle prostate biopsy

    Directory of Open Access Journals (Sweden)

    Julian Arista-Nasr

    2016-04-01

    Full Text Available ABSTRACT Purpose The vast majority of urothelial carcinomas infiltrating the bladder are consistent with high-grade tumors that can be easily recognized as malignant in needle prostatic biopsies. In contrast, the histological changes of low-grade urothelial carcinomas in this kind of biopsy have not been studied. Materials and Methods We describe the clinicopathologic features of two patients with low-grade bladder carcinomas infiltrating the prostate. They reported dysuria and hematuria. Both had a slight elevation of the prostate specific antigen and induration of the prostatic lobes. Needle biopsies were performed. At endoscopy bladder tumors were found in both cases. Results Both biopsies showed nests of basophilic cells and cells with perinuclear clearing and slight atypia infiltrating acini and small prostatic ducts. The stroma exhibited extensive desmoplasia and chronic inflammation. The original diagnosis was basal cell hyperplasia and transitional metaplasia. The bladder tumors also showed low-grade urothelial carcinoma. In one case, the neoplasm infiltrated the lamina propria, and in another, the muscle layer. In both, a transurethral resection was performed for obstructive urinary symptoms. The neoplasms were positive for high molecular weight keratin (34BetaE12 and thrombomodulin. No metastases were found in either of the patients, and one of them has survived for five years. Conclusions The diagnosis of low-grade urothelial carcinoma in prostate needle biopsies is difficult and may simulate benign prostate lesions including basal cell hyperplasia and urothelial metaplasia. It is crucial to recognize low-grade urothelial carcinoma in needle biopsies because only an early diagnosis and aggressive treatment can improve the prognosis for these patients.

  6. Diagnostic Yield of Transbronchial Biopsy in Comparison to High Resolution Computerized Tomography in Sarcoidosis Cases

    Science.gov (United States)

    Akten, H Serpil; Kilic, Hatice; Celik, Bulent; Erbas, Gonca; Isikdogan, Zeynep; Turktas, Haluk; Kokturk, Nurdan

    2018-04-25

    This study aimed to evaluate the diagnostic yield of fiberoptic bronchoscopic (FOB) transbronchial biopsy and its relation with quantitative findings of high resolution computerized tomography (HRCT). A total of 83 patients, 19 males and 64 females with a mean age of 45.1 years diagnosed with sarcoidosis with complete records of high resolution computerized tomography were retrospectively recruited during the time period from Feb 2005 to Jan 2015. High resolution computerized tomography scans were retrospectively assessed in random order by an experienced observer without knowledge of the bronchoscopic results or lung function tests. According to the radiological staging with HRCT, 2.4% of the patients (n=2) were stage 0, 19.3% (n=16) were stage 1, 72.3% (n=60) were stage 2 and 6.0% (n=5) were stage 3. This study showed that transbronchial lung biopsy showed positive results in 39.7% of the stage I or II sarcoidosis patients who were diagnosed by bronchoscopy. Different high resolution computerized tomography patterns and different scores of involvement did make a difference in the diagnostic accuracy of transbronchial biopsy (p=0.007). Creative Commons Attribution License

  7. Coeliac disease: to biopsy or not?

    Science.gov (United States)

    Reilly, Norelle R; Husby, Steffen; Sanders, David S; Green, Peter H R

    2018-01-01

    Coeliac disease is increasingly recognized as a global problem in both children and adults. Traditionally, the findings of characteristic changes of villous atrophy and increased intraepithelial lymphocytosis identified in duodenal biopsy samples taken during upper gastrointestinal endoscopy have been required for diagnosis. Although biopsies remain advised as necessary for the diagnosis of coeliac disease in adults, European guidelines for children provide a biopsy-sparing diagnostic pathway. This approach has been enabled by the high specificity and sensitivity of serological testing. However, these guidelines are not universally accepted. In this Perspective, we discuss the pros and cons of a biopsy-avoiding pathway for the diagnosis of coeliac disease, especially in this current era of the call for more biopsies, even from the duodenal bulb, in the diagnosis of coeliac disease. In addition, a contrast between paediatric and adult guidelines is presented.

  8. Risk factors for bleeding complications after nephrologist-performed native renal biopsy.

    Science.gov (United States)

    Lees, Jennifer S; McQuarrie, Emily P; Mordi, Natalie; Geddes, Colin C; Fox, Jonathan G; Mackinnon, Bruce

    2017-08-01

    Bleeding is a recognized complication of native percutaneous renal biopsy. This study aimed to describe the incidence of major bleeding after biopsy in a single centre over a 15-year period and examine factors associated with major bleeding. We identified consecutive adult patients undergoing ultrasound-guided native renal biopsy in the Glasgow Renal and Transplant Unit from 2000 to 2014. From the electronic patient record, we collected data pertaining to biopsy indication, pre- and post-biopsy laboratory measurements, prescribed medication and diagnosis. Aspirin was routinely continued. We defined major bleeding post-biopsy as the need for blood transfusion, surgical or radiological intervention or death. Binary logistic regression analysis was used to assess factors associated with increased risk of major bleeding. There were 2563 patients who underwent native renal biopsy (1499 elective, 1064 emergency). The average age of patients was 57 (SD 17) years and 57.4% were male. Overall, the rate of major bleeding was 2.2%. In all, 46 patients required transfusion (1.8%), 9 patients underwent embolization (0.4%), no patient required nephrectomy and 1 patient died as a result of a significant late retroperitoneal bleed. Major bleeding was more common in those undergoing emergency compared with elective renal biopsy (3.4 versus 1.1%; P 30). The risk of major bleeding following native renal biopsy in the modern era is low. Complications are more common when biopsy is conducted as an emergency, which has implications for obtaining informed consent. Our data support the strategy of not stopping aspirin before renal biopsy.

  9. CT-Guided Transgluteal Biopsy for Systematic Random Sampling of the Prostate in Patients Without Rectal Access.

    Science.gov (United States)

    Goenka, Ajit H; Remer, Erick M; Veniero, Joseph C; Thupili, Chakradhar R; Klein, Eric A

    2015-09-01

    The objective of our study was to review our experience with CT-guided transgluteal prostate biopsy in patients without rectal access. Twenty-one CT-guided transgluteal prostate biopsy procedures were performed in 16 men (mean age, 68 years; age range, 60-78 years) who were under conscious sedation. The mean prostate-specific antigen (PSA) value was 11.4 ng/mL (range, 2.3-39.4 ng/mL). Six had seven prior unsuccessful transperineal or transurethral biopsies. Biopsy results, complications, sedation time, and radiation dose were recorded. The mean PSA values and number of core specimens were compared between patients with malignant results and patients with nonmalignant results using the Student t test. The average procedural sedation time was 50.6 minutes (range, 15-90 minutes) (n = 20), and the mean effective radiation dose was 8.2 mSv (median, 6.6 mSv; range 3.6-19.3 mSv) (n = 13). Twenty of the 21 (95%) procedures were technically successful. The only complication was a single episode of gross hematuria and penile pain in one patient, which resolved spontaneously. Of 20 successful biopsies, 8 (40%) yielded adenocarcinoma (Gleason score: mean, 8; range, 7-9). Twelve biopsies yielded nonmalignant results (60%): high-grade prostatic intraepithelial neoplasia (n = 3) or benign prostatic tissue with or without inflammation (n = 9). Three patients had carcinoma diagnosed on subsequent biopsies (second biopsy, n = 2 patients; third biopsy, n = 1 patient). A malignant biopsy result was not significantly associated with the number of core specimens (p = 0.3) or the mean PSA value (p = 0.1). CT-guided transgluteal prostate biopsy is a safe and reliable technique for the systematic random sampling of the prostate in patients without a rectal access. In patients with initial negative biopsy results, repeat biopsy should be considered if there is a persistent rise in the PSA value.

  10. Renal biopsies in children: current practice and audit of outcomes.

    Science.gov (United States)

    Hussain, Farida; Mallik, Meeta; Marks, Stephen D; Watson, Alan R

    2010-02-01

    There is considerable variation in the way that children are prepared for and the techniques employed in a renal biopsy. There was national agreement between UK paediatric renal centres to review current practice and audit outcomes An initial questionnaire survey was undertaken and a 12-month prospective audit performed of renal biopsies against agreed standards for the number of needle passes, adequacy of biopsy material and complication rates. Eleven of 13 centres participated. Information leaflets are sent pre-biopsy in five centres with only one using play preparation. Six of 11 routinely perform biopsies as day-case (DC) procedures and 6 use general anaesthesia (GA). Real-time ultrasound is the favoured method in eight centres. Biopsies are performed by nephrologists only in four centres, nephrologists with radiologists in five and radiology alone in two. Of 531 biopsies (352 native), 31% were performed as a DC with 49% being done under GA. The standard for the number of passes of native kidneys (95%). The major complication rate was higher than the standard of biopsy was performed as a DC or inpatient procedure (P = 0.73) or when GA or sedation was used (P = 0.8). The audit highlights significant variation in clinical practice with limited use of preparation materials and DC procedures. The results have stimulated constructive debate about preparation and indications for biopsy and training issues. The audit enables centres and individuals to monitor performance.

  11. Ultrasound-guided percutaneous biopsy of digestive tract lesions

    International Nuclear Information System (INIS)

    Gil, S.; Martin, I.; Ballesteros, J. M.; Gomez, C.; Marco, S. F.; Fernandez, P.

    1999-01-01

    To present our experience in ultrasound-guided percutaneous biopsy of lesions located in the digestive tract. We performed ultrasound-guided percutaneous biopsy in 14 patients (10 men and 4 women) ranging in age from 7 to 71 years (mean; 519 years). The lesions were located throughout the digestive tract, from the pyriform sinus to the sigmoid colon. The biopsy was carried out with a 5 MHz convex probe equipped with a device to direct the needle. An 18G automatic needle or a 20G Chiba needle was used to obtain specimens for histological study in every case, and additional samples were collected with a 22G needle for cytological examination in 13 of the patients. The ultrasound images corresponded to pseudokidney in 9 cases and extrinsic masses in 5. The diagnosis was obtained from the histological examination in every case (100%) and from cytology in 6 (44.4%), the latter results were less specific. The only complication corresponded to a case of bilioperitoneum. Ultrasound-guided percutaneous biopsy is a suitable technique for the histological diagnosis of those lesions of the digestive tract that are visible in ultrasound images, but that for some reason can not be examined by endoscopic biopsy. (Author) 20 refs

  12. Study of CT-guided percutaneous biopsy for the spine lesions

    International Nuclear Information System (INIS)

    Zhang Ji; Wu Chungen; Cheng Yongde; Zhu Xuee; Gu Yifeng; Zhang Huijian

    2008-01-01

    Objective: To determine the successful rate, diagnostic accuracy and clinical usefulness of CT-guided percutaneous biopsy for the spine lesions. Methods: Eight-five patients (61 outpatients, 24 ward patients)underwent CT-guided percutaneous biopsy for the spine lesion. The imaging appearance of spinal lesions were lytic in 57 cases, osteosclerotic in 19 cases, and mixed in 9 cases. Biopsy specimens were sent for cytologic and histologic analysis in order to correct diagnosis. Bacterial studies were performed when ever infection was suspected. Results: The localization of puncture biopsy needle inside the spinal lesions, was conformed by computed tomography including 3 cervical, 26 thoracic, 37 lumbar, and 19 sacral lesions. Biopsy specimens included bone (29 cases), soft tissue (5 cases), mixed tissue (47 cases )and no specimen be obtained(4 cases). An adequate specimen for pathologic examination was obtained in 81 biopsies (95%). The pathologic examinations revealed 44 metastases, 17 primary bone neoplasms, 18 infections (included tuberculosis)and 2 normal tissues of vertebral body. The diagnostic accuracy reached 97.5% (79 of 81 patients). Conclusions: CT-guided percutaneous biopsy is an important tool in the evaluation of spinal lesions, providing accurate localization, less trauma and reliable pathologic diagnosis and worthwhile to be the routine before vertebroplasy. (authors)

  13. Mammotome HH biopsy - the future of minimal invasive breast surgery?

    International Nuclear Information System (INIS)

    Pietrzyk, G.; Nowicki, J.; Bojarski, B.; Kedzierski, B.; Wysocki, A.; Prudlak, E.

    2007-01-01

    Vacuum-assisted breast biopsy / Mammotome HH '' R '' Breast Biopsy System/ is the milestone in the diagnosis of breast lesions. This system has proven to be as diagnostically reliable as open surgery, but without scarring, deformations and hospitalizations associated with an open procedure. The aim of our study was to assess the role and possibilities of using this biopsy in treatment of benign breast lesions like fibroadenoma. From 2001 to 2004, about 1118 Mammotome biopsies were performed in our Department. Among 445 Mammotome biopsies performed under US control there were 211 cases of fibroadenomas. Follow-up was performed in 156 patients with this result at 6 and 12 months after biopsy. In our study we took into considerations the size, localizations as well as performers. In 2002 there were 70.8% patients with total lesion excision, 16.7% with residual lesion and 12.5% women with hematomas or scars. In 2003-2004 there were more women with total lesion excision (84.3%), fewer residual tumors and other lesions. In future, Mammotome breast biopsy can replace scalpel, and will become an alternative method to open surgical excision of fibroadenomas. It is important especially in the cases of young women to prevent cosmetic deformations and scars. (author)

  14. [Current situation and prospect of breast cancer liquid biopsy].

    Science.gov (United States)

    Zhou, B; Xin, L; Xu, L; Ye, J M; Liu, Y H

    2018-02-01

    Liquid biopsy is a diagnostic approach by analyzing body fluid samples. Peripheral blood is the most common sample. Urine, saliva, pleural effusion and ascites are also used. Now liquid biopsy is mainly used in the area of neoplasm diagnosis and treatment. Compared with traditional tissue biopsy, liquid biopsy is minimally invasive, convenient to sample and easy to repeat. Liquid biopsy mainly includes circulating tumor cells and circulating tumor DNA (ctDNA) detection. Detection of ctDNA requires sensitive and accurate methods. The progression of next-generation sequencing (NGS) and digital PCR promote the process of studies in ctDNA. In 2016, Nature published the result of whole-genome sequencing study of breast cancer. The study found 1 628 mutations of 93 protein-coding genes which may be driver mutations of breast cancer. The result of this study provided a new platform for breast cancer ctDNA studies. In recent years, there were many studies using ctDNA detection to monitor therapeutic effect and guide treatment. NGS is a promising technique in accessing genetic information and guiding targeted therapy. It must be emphasized that ctDNA detection using NGS is still at research stage. It is important to standardize ctDNA detection technique and perform prospective clinical researches. The time is not ripe for using ctDNA detection to guide large-scale breast cancer clinical practice at present.

  15. Value of CT-guided biopsy in malignant lymphoma; Wertigkeit der CT-gesteuerten Biopsie maligner Lymphome

    Energy Technology Data Exchange (ETDEWEB)

    Libicher, M.; Noeldge, G.; Radeleff, B.; Gholipur, F.; Richter, G.M. [Abteilung Radiodiagnostik, Universitaetsklinikum Heidelberg (Germany)

    2002-12-01

    Management of diagnosing malignant lymphomas has changed with development of CT-guided techniques and reliable biopsy tools.Pathologists can use representative tissue samples for sub classification in more than 90%.Evaluation of residual lymphoma or relapse can be nearly as effective. Therefore percutaneous biopsy can be considered as primary diagnostic tool in the absence of peripheral lymphadenopathy. CT-guided biopsies can be performed on an outpatient basis under conscious sedation considering contraindications as well as regional complications. Acceptance of percutaneous biopsy by the pathologist and oncologist is based on diagnostic effectiveness that is significantly improved if more than 3{dagger}solid tissue samples are taken. This article reviews the value of CT-guided biopsy in comparison to surgical procedures in patients with malignant lymphoma. Essential aspects that lead to a diagnostic percutaneous biopsy are discussed on grounds of the current literature. (orig.) [German] Mit der Entwicklung CT-gesteuerter Biopsieverfahren sowie zuverlaessiger Biopsiesysteme hat sich die Vorgehensweise bei der Diagnostik maligner Lymphome geaendert. Repraesentative Stanzzylinder mit hoher Praeparatequalitaet ermoeglichen dem Pathologen eine Subklassifikation der Lymphome in ueber 90%. Eine aehnlich hohe Treffsicherheit ist auch bei der Rezidivdiagnostik moeglich. Deshalb sind perkutane Biopsien bei fehlender peripherer Lymphadenopathie als primaere diagnostische Methode geeignet. Unter Beachtung der Kontraindikationen sowie der regional unterschiedlichen Komplikationsmoeglichkeiten koennen die meisten CT-gesteuerten Biopsien ambulant unter Analgosedierung durchgefuehrt werden. Die Akzeptanz perkutaner Biopsien durch Pathologen und Onkologen ist an die diagnostische Genauigkeit gekoppelt. Diese wird durch Gewinnung von mindestens 3 repraesentativen Biopsiezylindern aus den soliden Anteilen eines Lymphoms signifikant erhoeht. Die vorliegende Uebersichtsarbeit

  16. An Unexpected Complication of Bone Marrow Aspiration and Trephine Biopsy: Arteriovenous Fistula

    Science.gov (United States)

    Berber, Ilhami; Erkurt, Mehmet Ali; Kuku, Irfan; Kaya, Emin; Kutlu, Ramazan; Koroglu, Mustafa; Yigit, Ali; Unlu, Serkan

    2014-01-01

    Objective To report a case of arteriovenous fistula (AVF) following bone marrow aspiration and trephine biopsy. Clinical Presentation and Intervention A 76-year-old man was diagnosed with acute myeloblastic leukemia. Pain and hematoma were detected in his left leg and hip 4 days after bone marrow aspiration and trephine biopsy. A pelvic arteriography was performed, and a diagnosis of AVF was made. Conclusion This case shows that clinicians should be aware of AVF, especially in cases with refractory bleeding after bone marrow aspiration and trephine biopsy despite normal blood coagulation parameters. PMID:24481007

  17. Is the Diagnosis of Celiac Disease Possible Without Intestinal Biopsy?

    Directory of Open Access Journals (Sweden)

    Maha Shomaf

    2017-08-01

    Full Text Available Background: Coeliac disease is defined as a state of immune-mediated hyper-responsiveness to dietary gluten from wheat, barley, or rye in genetically predisposed individuals that results in tissue damage. The diagnosis is made by microscopic examination of a small intestinal biopsy, although serological testing for antibodies against tissue transglutaminase and deamidated gliadin peptide can be of great advantage. It has been suggested that duodenal biopsy can be avoided in patients with high levels of the tissue transglutaminase antibody, since a relationship has been found to be present between tissue transglutaminase antibody titres and coeliac disease. Aims: To study the correlation between tissue transglutaminase titre and small intestinal biopsy findings in patients with coeliac disease. Study Design: Diagnostic accuracy study. Methods: Ninety-five cases of patients diagnosed with coeliac disease and with positive serum tissue transglutaminase titres were retrieved from the Jordan University Hospital archives between December 2014 and December 2015. All the cases were classified according to the Marsh classification. Results: Ninety-five cases with a positive titre for the antibody were included in this study, 73 (76.8% of them were females and 22 cases (23.2% were males. The age of the patients ranged between 4 and 75 years with a mean age ± standard deviation of 32.3±14.7. The sensitivity was the highest in Marsh IIIC and lowest in Marsh IIIA (95% versus 68% respectively. The specificity was moderate (76% for all subtypes of Marsh III. Conclusion: This study showed a positive correlation between the tissue transglutaminase titre and the degree of duodenal damage (Marsh IIIC in patients with coeliac disease. In the presence of high tissue transglutaminase levels, duodenal biopsy might not be always necessary for diagnosis, particularly in symptomatic patients

  18. 'Microerosions' in rectal biopsies in Crohn's disease

    DEFF Research Database (Denmark)

    Poulsen, Steen Seier

    1984-01-01

    Small (less than 1 mm), superficial erosions ('microerosions') have been observed stereo-microscopically in surface-stained rectal biopsies in Crohn's disease (CD). Biopsy specimens from 97 patients with CD, 225 with ulcerative colitis (UC), and a control material of 161 patients were investigated....... Granulomas were identified in 62% of the biopsies with microerosions and by examination of two consecutive biopsies from each of these patients, in 85% indicating a positive correlation. In patients with microerosions and a primary diagnosis of UC, granulomas were found in 38% and by examination of two...... biopsies in 54%. Patients with granulomas and a few other patients were reclassified as CD, but there still remained some patients with microerosions, who most probably had UC. In conclusion, microerosions are observed mainly in CD with colonic involvement. There is a high incidence of granulomas in biopsy...

  19. Analysis of histological findings obtained combining US/mp-MRI fusion-guided biopsies with systematic US biopsies: mp-MRI role in prostate cancer detection and false negative.

    Science.gov (United States)

    Faiella, Eliodoro; Santucci, Domiziana; Greco, Federico; Frauenfelder, Giulia; Giacobbe, Viola; Muto, Giovanni; Zobel, Bruno Beomonte; Grasso, Rosario Francesco

    2018-02-01

    To evaluate the diagnostic accuracy of mp-MRI correlating US/mp-MRI fusion-guided biopsy with systematic random US-guided biopsy in prostate cancer diagnosis. 137 suspected prostatic abnormalities were identified on mp-MRI (1.5T) in 96 patients and classified according to PI-RADS score v2. All target lesions underwent US/mp-MRI fusion biopsy and prostatic sampling was completed by US-guided systematic random 12-core biopsies. Histological analysis and Gleason score were established for all the samples, both target lesions defined by mp-MRI, and random biopsies. PI-RADS score was correlated with the histological results, divided in three groups (benign tissue, atypia and carcinoma) and with Gleason groups, divided in four categories considering the new Grading system of the ISUP 2014, using t test. Multivariate analysis was used to correlate PI-RADS and Gleason categories to PSA level and abnormalities axial diameter. When the random core biopsies showed carcinoma (mp-MRI false-negatives), PSA value and lesions Gleason median value were compared with those of carcinomas identified by mp-MRI (true-positives), using t test. There was statistically significant difference between PI-RADS score in carcinoma, atypia and benign lesions groups (4.41, 3.61 and 3.24, respectively) and between PI-RADS score in Gleason  7 group (4.14 and 4.79, respectively). mp-MRI performance was more accurate for lesions > 15 mm and in patients with PSA > 6 ng/ml. In systematic sampling, 130 (11.25%) mp-MRI false-negative were identified. There was no statistic difference in Gleason median value (7.0 vs 7.06) between this group and the mp-MRI true-positives, but a significant lower PSA median value was demonstrated (7.08 vs 7.53 ng/ml). mp-MRI remains the imaging modality of choice to identify PCa lesions. Integrating US-guided random sampling with US/mp-MRI fusion target lesions sampling, 3.49% of false-negative were identified.

  20. Minimal invasive biopsy results of 'uncertain malignant potential' in digital mammography screening. High prevalence but also high predictive value for malignancy

    Energy Technology Data Exchange (ETDEWEB)

    Weigel, S.; Heindel, W. [Universitaetsklinikum Muenster (Germany). Inst. fuer Klinische Radiologie; Universitaetsklinikum Muenster (Germany). Referenzzentrum Mammographie; Decker, T. [Dietrich Bonhoeffer Klinikum, Neubrandenburg (Germany). Inst. fuer Pathologie; Universitaetsklinikum Muenster (Germany). Referenzzentrum Mammographie; Korsching, E. [Universitaetsklinikum Muenster (Germany). Inst. fuer Bioinformatik; Biesheuvel, C.; Woestmann, A.; Boecker, W. [Universitaetsklinikum Muenster (Germany). Referenzzentrum Mammographie; Hungermann, D. [Universitaetsklinikum Muenster (Germany). Gerhard-Domagk-Inst. fuer Pathologie; Roterberg, K.; Tio, J. [Universitaetsklinikum Muenster (Germany). Klinik und Poliklinik fuer Frauenheilkunde und Geburtshilfe, Bereich Senologie

    2011-08-15

    Purpose: To evaluate the rate, the histological spectrum and the positive predictive value (PPV) for malignancy of minimally invasive biopsies with 'uncertain malignant potential (B3)' in digital mammography screening. Methods and Materials: Consecutive data of 37 178 participants of one digital unit of the German screening program were included. Results: The B 3 rate was 15.1 % (148/979). The frequencies of lesion subtypes were as follows: atypical epithelial proliferation of ductal type (AEPDT) 35.1 % (52/148), radial scar (RS) 28.4 % (42/148), papillary lesions (PAP) 20.3 % (30/148), lobular carcinoma in situ 8.8 % (13/148), flat epithelial atypia 5.4 % (8/148), and mucocele-like lesions 2.0 % (3/148). The PPV for malignancy in surgical excisions was overall 0.28 (25/91); in detail 0.40 (19/47) for AEPDT, 0.20 (5/25) for RS, 0.08 (1/12) for PAP. Conclusion: Despite a higher B 3 rate of minimally invasive biopsies with 'uncertain malignant potential' in digital screening, the benign surgical biopsy rate is not disproportionally increased compared with analog screening programs. Together with defined management protocols, this results in an increased cancer detection rate per screening participant with surgical excision. (orig.)

  1. Protocol renal biopsy in patients with lupus nephritis: a single center experience.

    Science.gov (United States)

    Singh, Ametashver; Ghosh, Rabindranath; Kaur, Prabhjeet; Golay, Vishal; Pandey, Rajendra; Roychowdhury, Arpita

    2014-07-01

    Renal biopsy plays an indispensable role in the diagnosis and management of patients with lupus nephritis (LN). A number of studies have evaluated the role of a repeat biopsy in case of disease relapse or treatment unresponsiveness. We studied 40 patients with LN with renal biopsies performed at baseline and after six months of therapy. The baseline and protocol biopsies were compared with respect to histological class transformation, crescents, tubular atrophy, interstitial fibrosis and glomerulosclerosis. We also compared serum creatinine, hemoglobin, systemic lupus erythematosus disease activity index (SLEDAI) scores, 24-h urine protein excretion and C3levels as well as activity index (AI) and chronicity index (CI) at baseline and at six months. Comparison of means was made by paired t test, McNemar test and marginal homogeneity test (multinomial data). Histological class transformation was seen in 10 patients (25%). Intra-class progression to greater chronicity was seen in 10 other patients (25%).There was an increase in glomerulosclerosis, tubular atrophy, interstitial fibrosis and a reduction in cellularity, crescent formation and wire loop lesions in the protocol biopsy. A decline in AI (6.05 vs. 2.50, P protocol biopsy. Our study shows a trend toward greater chronicity in protocol biopsies in LN.

  2. Accuracy of CT-guided percutaneous core needle biopsy for assessment of pediatric musculoskeletal lesions

    International Nuclear Information System (INIS)

    Hryhorczuk, Anastasia L.; Strouse, Peter J.; Biermann, J.S.

    2011-01-01

    CT-guided percutaneous core needle biopsy has been shown in adults to be an effective diagnostic tool for a large number of musculoskeletal malignancies. To characterize our experience with CT-guided percutaneous core needle biopsy of pediatric bone lesions and determine its utility in diagnosing pediatric osseous lesions, in a population where such lesions are commonly benign. From 2000 to 2009, 61 children underwent 63 CT-guided percutaneous biopsies. Radiological, pathological and clinical records were reviewed. Fourteen biopsies (22%) were performed on malignant lesions, while 49 biopsies (78%) were performed on benign lesions. Forty-nine of the 63 biopsies (78%) were adequate; these children underwent no further tissue sampling. Fourteen of the 63 biopsies (22%) were inadequate or non-conclusive. Of these patients, 12 underwent open biopsy. Retrospective analysis of percutaneous biopsies in these patients demonstrates that 9/12 provided clinically relevant information, and 4/12 patients received final diagnoses that confirmed initial core biopsy findings. No malignancies were diagnosed as benign on percutaneous biopsy. Overall, percutaneous core needle biopsy provided accurate diagnostic information in 84% (53/63) of biopsies. Our results demonstrate that CT-guided percutaneous biopsy is safe and beneficial in children. This study supports the use of CT-guided percutaneous core needle biopsy for primary diagnosis of pediatric bone lesions. (orig.)

  3. Frequency of precancerous lesions in endoscopic gastric biopsies in chronic gastritis

    International Nuclear Information System (INIS)

    Haroon, S.; Faridi, N.; Lodhi, F. R.; Mujtaba, S.

    2013-01-01

    Objective: To determine the frequency of precancerous lesions in endoscopic gastric biopsies of patients with chronic gastritis. Study Design: A case series. Place and Duration of Study: Department of Histopathology, Liaquat National Hospital, Karachi, from July 2008 to January 2009. Methodology: Over 6 months, 375 endoscopic gastric biopsies of patients with age group of 15-65 years having endoscopic chronic gastritis were included. From final biopsy report, basic information like patient demographics and presence of precancerous lesions i.e. activity (chronic active gastritis), atrophy (atrophic gastritis), intestinal metaplasia and dysplasia were recorded on proforma. Results were described as proportions and frequency. Results: The frequency of precancerous lesions in endoscopic gastric biopsies of patients with chronic gastritis in Karachi was markedly high. Most common lesion was chronic active gastritis as depicted by activity (48.3%); dysplasia (1.3%) was the least common. Proportion of more aggressive precancerous lesions were markedly higher in older age group (> 40 years). Conclusion: The precancerous lesions are frequent in endoscopic gastric biopsies of patients with chronic gastritis. (author)

  4. Combination of prostate imaging reporting and data system (PI-RADS) score and prostate-specific antigen (PSA) density predicts biopsy outcome in prostate biopsy naïve patients.

    Science.gov (United States)

    Washino, Satoshi; Okochi, Tomohisa; Saito, Kimitoshi; Konishi, Tsuzumi; Hirai, Masaru; Kobayashi, Yutaka; Miyagawa, Tomoaki

    2017-02-01

    To assess the value of the Prostate Imaging Reporting and Data System (PI-RADS) scoring system, for prostate multi-parametric magnetic resonance imaging (mpMRI) to detect prostate cancer, and classical parameters, such as prostate-specific antigen (PSA) level, prostate volume and PSA density, for predicting biopsy outcome in biopsy naïve patients who have suspected prostate cancer. Patients who underwent mpMRI at our hospital, and who had their first prostate biopsy between July 2010 and April 2014, were analysed retrospectively. The prostate biopsies were taken transperineally under transrectal ultrasonography guidance. In all, 14 cores were biopsied as a systematic biopsy in all patients. Two cognitive fusion-targeted biopsy cores were added for each lesion in patients who had suspicious or equivocal lesions on mpMRI. The PI-RADS scoring system version 2.0 (PI-RADS v2) was used to describe the MRI findings. Univariate and multivariate analyses were performed to determine significant predictors of prostate cancer and clinically significant prostate cancer. In all, 288 patients were analysed. The median patient age, PSA level, prostate volume and PSA density were 69 years, 7.5 ng/mL, 28.7 mL, and 0.26 ng/mL/mL, respectively. The biopsy results were benign, clinically insignificant, and clinically significant prostate cancer in 129 (45%), 18 (6%) and 141 (49%) patients, respectively. The multivariate analysis revealed that PI-RADS v2 score and PSA density were independent predictors for prostate cancer and clinically significant prostate cancer. When PI-RADS v2 score and PSA density were combined, a PI-RADS v2 score of ≥4 and PSA density ≥0.15 ng/mL/mL, or PI-RADS v2 score of 3 and PSA density of ≥0.30 ng/mL/mL, was associated with the highest clinically significant prostate cancer detection rates (76-97%) on the first biopsy. Of the patients in this group with negative biopsy results, 22% were subsequently diagnosed as prostate cancer. In contrast, a PI

  5. Biopsying southern right whales : Their reactions and effects on reproduction

    NARCIS (Netherlands)

    Best, PB; Reeb, D; Rew, MB; Palsboll, PJ; Schaeff, C; Brandao, A

    Collecting skin biopsies from large whales for genetic analysis is often subject to national permit, and in the case of cow-calf pairs, it may be prohibited. We present results of 906 biopsy attempts on southern fight whales (Eubalaena australis) in South African waters between 1995 and 1997,

  6. Optical coherence elastography (OCE) as a method for identifying benign and malignant prostate biopsies

    Science.gov (United States)

    Li, Chunhui; Guan, Guangying; Ling, Yuting; Lang, Stephen; Wang, Ruikang K.; Huang, Zhihong; Nabi, Ghulam

    2015-03-01

    Objectives. Prostate cancer is the most frequently diagnosed malignancy in men. Digital rectal examination (DRE) - a known clinical tool based on alteration in the mechanical properties of tissues due to cancer has traditionally been used for screening prostate cancer. Essentially, DRE estimates relative stiffness of cancerous and normal prostate tissue. Optical coherence elastography (OCE) are new optical imaging techniques capable of providing cross-sectional imaging of tissue microstructure as well as elastogram in vivo and in real time. In this preliminary study, OCE was used in the setting of the human prostate biopsies ex vivo, and the images acquired were compared with those obtained using standard histopathologic methods. Methods. 120 prostate biopsies were obtained by TRUS guided needle biopsy procedures from 9 patients with clinically suspected cancer of the prostate. The biopsies were approximately 0.8mm in diameter and 12mm in length, and prepared in Formalin solution. Quantitative assessment of biopsy samples using OCE was obtained in kilopascals (kPa) before histopathologic evaluation. The results obtained from OCE and standard histopathologic evaluation were compared provided the cross-validation. Sensitivity, specificity, and positive and negative predictive values were calculated for OCE (histopathology was a reference standard). Results. OCE could provide quantitative elasticity properties of prostate biopsies within benign prostate tissue, prostatic intraepithelial neoplasia, atypical hyperplasia and malignant prostate cancer. Data analysed showed that the sensitivity and specificity of OCE for PCa detection were 1 and 0.91, respectively. PCa had significantly higher stiffness values compared to benign tissues, with a trend of increasing in stiffness with increasing of malignancy. Conclusions. Using OCE, microscopic resolution elastogram is promising in diagnosis of human prostatic diseases. Further studies using this technique to improve the

  7. Freehand biopsy guided by electromagnetic needle tracking

    DEFF Research Database (Denmark)

    Ewertsen, C; Nielsen, Marie Kristina Rue; Nielsen, M Bachmann

    2011-01-01

    To evaluate the overall accuracy and time spent on biopsy guided by electromagnetic needle tracking in a phantom compared with the standard technique of US-guided biopsy with an attached steering device. Furthermore, to evaluate off-plane biopsy guided by needle tracking....

  8. Stereotactic biopsy of cerebellar lesions: straight versus oblique frame positioning.

    Science.gov (United States)

    Quick-Weller, Johanna; Brawanski, Nina; Dinc, Nazife; Behmanesh, Bedjahn; Kammerer, Sara; Dubinski, Daniel; Seifert, Volker; Marquardt, Gerhard; Weise, Lutz

    2017-10-26

    Biospies of brain lesions with unknown entity are an everyday procedure among many neurosurgical departments. Biopsies can be performed frame-guided or frameless. However, cerebellar lesions are a special entity with a more complex approach. All biopsies in this study were performed stereotactically frame guided. Therefore, only biopsies of cerebellar lesions were included in this study. We compared whether the frame was attached straight versus oblique and we focused on diagnostic yield and complication rate. We evaluated 20 patients who underwent the procedure between 2009 and 2017. Median age was 56.5 years. 12 (60%) Patients showed a left sided lesion, 6 (30%) showed a lesion in the right cerebellum and 2 (10%) patients showed a midline lesion. The stereotactic frame was mounted oblique in 12 (60%) patients and straight in 8 (40%) patients. Postoperative CT scan showed small, clinically silent blood collection in two (10%) of the patients, one (5%) patient showed haemorrhage, which caused a hydrocephalus. He received an external ventricular drain. In both patients with small haemorrhage the frame was positioned straight, while in the patient who showed a larger haemorrhage the frame was mounted oblique. In all patients a final histopathological diagnosis was established. Cerebellar lesions of unknown entity can be accessed transcerebellar either with the stereotactic frame mounted straight or oblique. Also for cerebellar lesions the procedure shows a high diagnostic yield with a low rate of severe complications, which need further treatment.

  9. A comparison of prostate tumor targeting strategies using magnetic resonance imaging-targeted, transrectal ultrasound-guided fusion biopsy.

    Science.gov (United States)

    Martin, Peter R; Cool, Derek W; Fenster, Aaron; Ward, Aaron D

    2018-03-01

    Magnetic resonance imaging (MRI)-targeted, three-dimensional (3D) transrectal ultrasound (TRUS)-guided prostate biopsy aims to reduce the 21-47% false-negative rate of clinical two-dimensional (2D) TRUS-guided systematic biopsy, but continues to yield false-negative results. This may be improved via needle target optimization, accounting for guidance system errors and image registration errors. As an initial step toward the goal of optimized prostate biopsy targeting, we investigated how needle delivery error impacts tumor sampling probability for two targeting strategies. We obtained MRI and 3D TRUS images from 49 patients. A radiologist and radiology resident assessed these MR images and contoured 81 suspicious regions, yielding tumor surfaces that were registered to 3D TRUS. The biopsy system's root-mean-squared needle delivery error (RMSE) and systematic error were modeled using an isotropic 3D Gaussian distribution. We investigated two different prostate tumor-targeting strategies using (a) the tumor's centroid and (b) a ring in the lateral-elevational plane. For each simulation, targets were spaced at equal arc lengths on a ring with radius equal to the systematic error magnitude. A total of 1000 biopsy simulations were conducted for each tumor, with RMSE and systematic error magnitudes ranging from 1 to 6 mm. The difference in median tumor sampling probability and probability of obtaining a 50% core involvement was determined for ring vs centroid targeting. Our simulation results indicate that ring targeting outperformed centroid targeting in situations where systematic error exceeds RMSE. In these instances, we observed statistically significant differences showing 1-32% improvement in sampling probability due to ring targeting. Likewise, we observed statistically significant differences showing 1-39% improvement in 50% core involvement probability due to ring targeting. Our results suggest that the optimal targeting scheme for prostate biopsy depends on

  10. The preventive effect of tamsulosin on voiding dysfunction after prostate biopsy: a prospective, open-label, observational study.

    Science.gov (United States)

    Chung, Seung Jun; Jung, Seung Il; Ryu, Ji Won; Hwang, Eu Chang; Kwon, Dong Deuk; Park, Kwangsung; Kim, Jin Woong

    2015-05-01

    To evaluate the association of prostate biopsy with voiding impairment and to investigate whether tamsulosin treatment given before prostate biopsy could improve voiding dysfunction after the procedure. The study included 88 consecutive patients who underwent transrectal ultrasound-guided prostate biopsy without prior BPH medication and were prospectively randomized. Of these 88 patients, 44 patients underwent prostate biopsy only without tamsulosin treatment and served as the control group. The remaining 44 patients were treated with tamsulosin (0.2 mg daily) beginning the day before the biopsy procedure for 7 days. The International Prostate Symptom Score (IPSS) was recorded in all patients before the procedure and on postbiopsy day 7. Maximal flow rate (Q(max)) and postvoid residual urine volume were recorded in all patients before the procedure and on postbiopsy days 1 and 7. No difference was found in baseline characteristics between the two groups. The IPSS (total, storage, and voiding symptom) was not significantly changed after biopsy in both groups. In the control group, the postvoid residual urine volume was increased on postbiopsy days 1 (P tamsulosin group, Q(max) was significantly increased on postbiopsy days 1 and 7 (P tamsulosin group, but it developed in two patients (4.5%) of the control group. The results of our study show that prostate biopsy leads to objective voiding impairment. Therefore, the use of alpha-1 blocker tamsulosin before biopsy in patients without prior BPH medication may decrease this morbidity.

  11. The accuracy of colposcopic biopsy

    DEFF Research Database (Denmark)

    Stoler, Mark H; Vichnin, Michelle D; Ferenczy, Alex

    2011-01-01

    We evaluated the overall agreement between colposcopically directed biopsies and the definitive excisional specimens within the context of three clinical trials. A total of 737 women aged 16-45 who had a cervical biopsy taken within 6 months before their definitive therapy were included. Per-prot...

  12. Biopsy techniques for intraocular tumors

    Directory of Open Access Journals (Sweden)

    Pukhraj Rishi

    2016-01-01

    Full Text Available Biopsy involves the surgical removal of a tissue specimen for histopathologic evaluation. Most intraocular tumors are reliably diagnosed based on the clinical evaluation or with noninvasive diagnostic techniques. However, accurately diagnosing a small percentage of tumors can be challenging. A tissue biopsy is thus needed to establish a definitive diagnosis and plan the requisite treatment. From fine-needle aspiration biopsy (FNAB to surgical excision, all tissue collection techniques have been studied in the literature. Each technique has its indications and limitations. FNAB has been reported to provide for 88-95% reliable and safe ophthalmic tumor diagnosis and has gained popularity for prognostic purposes and providing eye conserving treatment surgeries. The technique and instrumentation for biopsy vary depending upon the tissue involved (retina, choroid, subretinal space, vitreous, and aqueous, suspected diagnosis, size, location, associated retinal detachment, and clarity of the media. The cytopathologist confers a very important role in diagnosis and their assistance plays a key role in managing and planning the treatment for malignancies.

  13. IgG4-related disease with cavernous sinus and intra-orbital lesions diagnosed by nasal mucosa biopsy.

    Science.gov (United States)

    Nakata, Ruka; Yoshimura, Shunsuke; Motomura, Masakatsu; Tsujino, Akira; Hayashi, Tomayoshi; Hara, Minoru

    2016-09-29

    IgG4-related disease is a systemic disease characterized by lesions with IgG4 positive plasma cell infiltration in the involved organs and a raised serum IgG4 level. We report a patient of 70-year-old male presented orbital inflammation of IgG4-related disease. The patient developed right eye pain, double vision, and reduced eye sight. MRI image revealed mild right ocular proptosis and swelling of right carvenous sinus, bilateral intraorbital extraocular muscles and right optic nerve. Right optic nerve showed ring-like enhancement. IgG4-related disease was suspected with increased serum IgG4 level of 355 mg/dl, mediastinal lymphadenopathy and prostate enlargement. Transbronchial lung biopsy and prostate needle biopsy were administered with negative results. The eye related symptoms resolved with time, but serum IgG4 continuously increased. IgG4-related disease was diagnosed by nasal mucosa biopsy, which showed IgG4 positive plasma cells within the inflammatory infiltrate. This report emphasizes the usefulness of nasal mucosa biopsy for the diagnosis of IgG4 related disease with lesions difficult to approach.

  14. The predictive value of 2-year posttreatment biopsy after prostate cancer radiotherapy for eventual biochemical outcome

    International Nuclear Information System (INIS)

    Vance, Waseet; Tucker, Susan L.; Crevoisier, Renaud de; Kuban, Deborah A.; Cheung, M. Rex

    2007-01-01

    Purpose: To determine the value of a 2-year post-radiotherapy (RT) prostate biopsy for predicting eventual biochemical failure in patients who were treated for localized prostate cancer. Methods and Materials: This study comprised 164 patients who underwent a planned 2-year post-RT prostate biopsy. The independent prognostic value of the biopsy results for forecasting eventual biochemical outcome and overall survival was tested with other factors (the Gleason score, 1992 American Joint Committee on Cancer tumor stage, pretreatment prostate-specific antigen level, risk group, and RT dose) in a multivariate analysis. The current nadir + 2 (CN + 2) definition of biochemical failure was used. Patients with rising prostate-specific antigen (PSA) or suspicious digital rectal examination before the biopsy were excluded. Results: The biopsy results were normal in 78 patients, scant atypical and malignant cells in 30, carcinoma with treatment effect in 43, and carcinoma without treatment effect in 13. Using the CN + 2 definition, we found a significant association between biopsy results and eventual biochemical failure. We also found that the biopsy status provides predictive information independent of the PSA status at the time of biopsy. Conclusion: A 2-year post-RT prostate biopsy may be useful for forecasting CN + 2 biochemical failure. Posttreatment prostate biopsy may be useful for identifying patients for aggressive salvage therapy

  15. Accuracy of Core Needle Biopsy Versus Fine Needle Aspiration Cytology for Diagnosing Salivary Gland Tumors

    Directory of Open Access Journals (Sweden)

    In Hye Song

    2015-03-01

    Full Text Available Background: Core needle biopsy is a relatively new technique used to diagnose salivary gland lesions, and its role in comparison with fine needle aspiration cytology needs to be refined. Methods: We compared the results of 228 ultrasound-guided core needle biopsy and 371 fine needle aspiration procedures performed on major salivary gland tumors with their postoperative histological diagnoses. Results: Core needle biopsy resulted in significantly higher sensitivity and more accurate tumor subtyping, especially for malignant tumors, than fine needle aspiration. No patient developed major complications after core needle biopsy. Conclusions: We recommend ultrasoundguided core needle biopsy as the primary diagnostic tool for the preoperative evaluation of patients with salivary gland lesions, especially when malignancy is suspected.

  16. Identification of proteomic biomarkers predicting prostate cancer aggressiveness and lethality despite biopsy-sampling error

    OpenAIRE

    Shipitsin, M; Small, C; Choudhury, S; Giladi, E; Friedlander, S; Nardone, J; Hussain, S; Hurley, A D; Ernst, C; Huang, Y E; Chang, H; Nifong, T P; Rimm, D L; Dunyak, J; Loda, M

    2014-01-01

    Background: Key challenges of biopsy-based determination of prostate cancer aggressiveness include tumour heterogeneity, biopsy-sampling error, and variations in biopsy interpretation. The resulting uncertainty in risk assessment leads to significant overtreatment, with associated costs and morbidity. We developed a performance-based strategy to identify protein biomarkers predictive of prostate cancer aggressiveness and lethality regardless of biopsy-sampling variation. Methods: Prostatectom...

  17. Ga-68 DOTATOC PET/CT-Guided Biopsy and Cryoablation with Autoradiography of Biopsy Specimen for Treatment of Tumor-Induced Osteomalacia

    Energy Technology Data Exchange (ETDEWEB)

    Maybody, Majid, E-mail: maybodym@mskcc.org [Memorial Sloan Kettering Cancer Center, Interventional Radiology Service (United States); Grewal, Ravinder K. [Memorial Sloan Kettering Cancer Center, Molecular Imaging and Therapy Service, Department of Radiology (United States); Healey, John H. [Memorial Sloan Kettering Cancer Center, Orthopedic Surgical Oncology Service, Department of Surgery (United States); Antonescu, Cristina R. [Memorial Sloan Kettering Cancer Center, Department of Pathology (United States); Fanchon, Louise [Memorial Sloan Kettering Cancer Center, Department of Physics (United States); Hwang, Sinchun [Memorial Sloan Kettering Cancer Center, Department of Radiology (United States); Carrasquillo, Jorge A. [Memorial Sloan Kettering Cancer Center, Molecular Imaging and Therapy Service, Department of Radiology (United States); Kirov, Assen [Memorial Sloan Kettering Cancer Center, Department of Physics (United States); Farooki, Azeez [Memorial Sloan Kettering Cancer Center, Department of Medicine (United States)

    2016-09-15

    Tumor-induced osteomalacia (TIO) is a rare paraneoplastic syndrome caused by small benign tumors of mesenchymal origin also known as phosphaturic mesenchymal tumors mixed connective tissue variant. Excellent prognosis is expected with eradication of the culprit tumor. These small tumors are notoriously difficult to localize with conventional imaging studies; this often leads to an extensive work up and prolonged morbidity. We report a patient with clinical diagnosis of TIO whose culprit tumor was localized with Ga-68 DOTATOC PET/CT and MRI. Biopsy and cryoablation were performed under Ga-68 DOTATOC PET/CT guidance. Autoradiography of the biopsy specimen was performed and showed in situ correlation between Ga-68 DOTATOC uptake and histopathology with millimeter resolution.

  18. Computed tomography-guided needle biopsy of lung lesions in fourteen cats and dogs

    International Nuclear Information System (INIS)

    Yoshida, K.; Mori, T.; Yamada, M.; Sakaida, M.; Yonemaru, K.; Murakami, M.; Sakai, H.; Maruo, K.

    2007-01-01

    Computed tomography (CT)-guided fine-needle aspirates (FNA) or core biopsies of lung lesions were performed in nine dogs and five cats. A clinical diagnosis was obtained in twelve of fourteen animals (85%), namely 80% FNA and 100% core biopsies. Eight animals had other mass (es) apart from the lung, and five were diagnosed to metastases. In only one case, the lung mass was histopathologically diagnosed as a malignant primary tumor. Iatrogenic complications through the lung biopsies were noted in four animals, and three showed mild pneumothorax on CT images and one was bleeding from the needle. However, between fifteen and thirty minutes after the biopsy, no animal indicated signs of pneumothorax or hemorrhage

  19. VALIDITY OF CORE NEEDLE BIOPSY IN THE HISTOPATHOLOGICAL VERIFICATION OF PAROTID GLAND LESIONS

    Directory of Open Access Journals (Sweden)

    Oroz Aleksandar

    2016-07-01

    Full Text Available Background and purpose: An adequate diagnosis of a parotid gland enlargement is crucial for an appropriate treatment. The aim of the study was to evaluate effectiveness and minimal invasiveness of diagnostic procedures of core-needle biopsy. Materials and Methods: This study involved 67 patients, aged 40 to 90 years, with a tumor mass in the submandibular and parotid region. Method used for taking samples of pathological masses was BD Disposable guillotine spring-loaded needle for biopsies on soft tissues. Final diagnoses were established on the basis of surgical-pathological results in 67 cases, and on the basis of histopathological analysis of core-biopsy samples. Results: Compared with results of surgical biopsy, core-needle biopsy had sensitivity of 100% in differentiating benign from malignant lesions and in setting up an adequate diagnosis. Its positive predictive values were 100% in diagnosing malignancy. There were found 28 non-malignant and 39 malignant lesions with fewer disadvantages for patients.

  20. Improving CT-guided transthoracic biopsy of mediastinal lesions by diffusion-weighted magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Guimaraes, Marcos Duarte; TyngI, Chiang Cheng; Bitencourt, Almir Galvao Vieira; Gross, Jefferson Luiz; Zurstrassen, Charles Edouard, E-mail: marcosduarte500@gmail.com [AC Camargo Cancer Center, Sao Paulo, SP (Brazil); Hochhegger, Bruno [Universidade Federal de Ciencias da Saude de Porto Alegre (UFCSPA), RS (Brazil). Dept. de Radiologia; Benveniste, Marcelo Felipe Kuperman; Odisio, Bruno Calazans [University of Texas, MD Anderson Cancer Center, Houston, TX (United States); Marchiori, Edson [Universidade Federal do Rio de Janeiro (UFRJ), Petropolis, RJ (Brazil)

    2014-11-15

    Objectives: to evaluate the preliminary results obtained using diffusion-weighted magnetic resonance imaging and the apparent diffusion coefficient for planning computed tomography-guided biopsies of selected mediastinal lesions. Methods: eight patients with mediastinal lesions suspicious for malignancy were referred for computed tomography-guided biopsy. Diffusion-weighted magnetic resonance imaging and apparent diffusion coefficient measurement were performed to assist in biopsy planning with diffusion/computed tomography fused images. We selected mediastinal lesions that could provide discordant diagnoses depending on the biopsy site, including large heterogeneous masses, lesions associated with lung atelectasis or consolidation, lesions involving large mediastinal vessels and lesions for which the results of biopsy using other methods and histopathological examination were divergent from the clinical and radiological suspicion. Results: in all cases, the biopsy needle was successfully directed to areas of higher signal intensity on diffusion weighted sequences and the lowest apparent diffusion coefficient within the lesion (mean, 0.8 [range, 0.6–1.1]610{sup -3} mm{sup 2}/s), suggesting high cellularity. All biopsies provided adequate material for specific histopathological diagnoses of four lymphomas, two sarcomas and two thymoma s. Conclusion: functional imaging tools, such as diffusion-weighted imaging and the apparent diffusion coefficient, are promising for implementation in noninvasive and imaging-guided procedures. However, additional studies are needed to confirm that mediastinal biopsy can be improved with these techniques. (author)

  1. The accuracy of frozen section analysis in ultrasound- guided core needle biopsy of breast lesions

    International Nuclear Information System (INIS)

    Brunner, Andreas H; Sagmeister, Thomas; Kremer, Jolanta; Riss, Paul; Brustmann, Hermann

    2009-01-01

    Limited data are available to evaluate the accuracy of frozen section analysis and ultrasound- guided core needle biopsy of the breast. In a retrospective analysis data of 120 consecutive handheldultrasound- guided 14- gauge automated core needle biopsies (CNB) in 109 consecutive patients with breast lesions between 2006 and 2007 were evaluated. In our outpatient clinic120 CNB were performed. In 59/120 (49.2%) cases we compared histological diagnosis on frozen sections with those on paraffin sections of CNB and finally with the result of open biopsy. Of the cases 42/59 (71.2%) were proved to be malignant and 17/59 (28.8%) to be benign in the definitive histology. 2/59 (3.3%) biopsies had a false negative frozen section result. No false positive results of the intraoperative frozen section analysis were obtained, resulting in a sensitivity, specificity and positive predicting value (PPV) and negative predicting value (NPV) of 95%, 100%, 100% and 90%, respectively. Histological and morphobiological parameters did not show up relevance for correct frozen section analysis. In cases of malignancy time between diagnosis and definitive treatment could not be reduced due to frozen section analysis. The frozen section analysis of suspect breast lesions performed by CNB displays good sensitivity/specificity characteristics. Immediate investigations of CNB is an accurate diagnostic tool and an important step in reducing psychological strain by minimizing the period of uncertainty in patients with breast tumor

  2. Comparison between preoperative biopsy and post-excision ...

    African Journals Online (AJOL)

    Comparison between preoperative biopsy and post-excision histology results in sarcoma: Experience at Chris Hani Baragwanath Academic Hospital, Johannesburg, South Africa. KG Panda, MJ Hale, D Kruger, TE Luvhengo ...

  3. Benign core biopsy of probably benign breast lesions 2 cm or larger: correlation with excisional biopsy and long-term follow-up

    OpenAIRE

    Jung, Hyun Kyung; Moon, Hee Jung; Kim, Min Jung; Kim, Eun-Kyung

    2014-01-01

    Purpose: To evaluate the accuracy of benign core biopsy of probably benign breast lesions (category 3) 2 cm or larger on the basis of excisional biopsy and long-term follow-up. Methods: We retrospectively reviewed 146 category 3 lesions in 146 patients 2 cm or larger which were diagnosed as benign by ultrasound (US)-guided core biopsy. Patients were initially diagnosed as benign at core needle biopsy and then followed up with excisional biopsy (surgical excision, n=91; US-guided vacuum assist...

  4. Right atrial and right ventricular ultrasound-guided biopsy technique in standing horses.

    Science.gov (United States)

    Decloedt, A; de Clercq, D; Ven, S; van der Vekens, N; Chiers, K; van Loon, G

    2016-05-01

    Endomyocardial biopsies could be a valuable tool in equine cardiology for diagnosing myocardial disease, which is probably underdiagnosed in horses because of lack of specific diagnostic measures and limitations of currently available diagnostic methods. To describe a technique for serial right atrial and right ventricular endomyocardial biopsy in standing horses using a percutaneous approach through the jugular vein. Prospective study. Biopsy was performed in 10 healthy standing horses sedated with detomidine, under continuous electrocardiography monitoring. A 10 cm (n = 6), 45 cm (n = 1) or 98 cm (n = 3) introducer sheath was inserted into the right jugular vein. Under echocardiographic guidance, a biopsy forceps was introduced through the sheath into the right ventricle and right atrium and endomyocardial biopsies were acquired. In all horses, 3 right ventricular biopsies were obtained from the right ventricular apex and 3 right atrial biopsies were obtained from the dorsal right atrial wall near the tuberculum intervenosum. The presence of myocardial tissue was confirmed by histology. All horses showed atrial and ventricular premature depolarisations associated with acquisition of the biopsies. In 9 horses, the arrhythmia disappeared after retraction of the forceps and introducer sheath. In one horse, ventricular premature depolarisations disappeared only after 8 h. No other complications were observed. Endomyocardial biopsy of the right atrium and right ventricle could be performed in standing horses using a percutaneous approach through the jugular vein and was not associated with complications other than temporary arrhythmias. This technique may be useful for research purposes or as a diagnostic tool, although further research is needed to establish the safety of the technique in clinical patients with myocardial disease. © 2015 EVJ Ltd.

  5. Vortex-dislodged cells from bone marrow trephine biopsy yield satisfactory results for flow cytometric immunophenotyping.

    Science.gov (United States)

    Bommannan, K; Sachdeva, M U S; Gupta, M; Bose, P; Kumar, N; Sharma, P; Naseem, S; Ahluwalia, J; Das, R; Varma, N

    2016-10-01

    A good bone marrow (BM) sample is essential in evaluating many hematologic disorders. An unsuccessful BM aspiration (BMA) procedure precludes a successful flow cytometric immunophenotyping (FCI) in most hematologic malignancies. Apart from FCI, most ancillary diagnostic techniques in hematology are less informative. We describe the feasibility of FCI in vortex-dislodged cell preparation obtained from unfixed trephine biopsy (TB) specimens. In pancytopenic patients and dry tap cases, routine diagnostic BMA and TB samples were complemented by additional trephine biopsies. These supplementary cores were immediately transferred into sterile tubes filled with phosphate-buffered saline, vortexed, and centrifuged. The cell pellet obtained was used for flow cytometric immunophenotyping. Of 7955 BMAs performed in 42 months, 34 dry tap cases were eligible for the study. Vortexing rendered a cell pellet in 94% of the cases (32 of 34), and FCI rendered a rapid diagnosis in 100% of the cases (32 of 32) where cell pellets were available. We describe an efficient procedure which could be effectively utilized in resource-limited centers and reduce the frequency of repeat BMA procedures. © 2016 John Wiley & Sons Ltd.

  6. Extended analysis of AL-amyloid protein from abdominal wall subcutaneous fat biopsy

    DEFF Research Database (Denmark)

    Olsen, K E; Sletten, K; Westermark, Per

    1998-01-01

    a subcutaneous fat tissue biopsy and submitted to extended protein separation, typing and amino acid sequence analyses. The AL-protein belonged to the rare immunoglobulin light chain kappa, subtype kappa IV and contained unique amino acid substitutions, mostly in the highly preserved framework regions. The study...... shows that subcutaneous fat biopsies are useful sources of amyloid material for biochemical studies....

  7. Oral Biopsy: A Dental Gawk

    African Journals Online (AJOL)

    Sir,. Dermatologists are often confronted with neoplasms and diseases of the oral cavity. Although many may be reluctant to perform oral surgical procedures, a biopsy is often needed to establish a definitive diagnosis, and biopsy of the oral cavity is a safe and useful technique that can be easily employed by dermatologists.

  8. Efficacy and Complications of Ultrasound-Guided Percutaneous Renal Biopsy Using Automatic Biopsy Gun in Pediatric Diffuse Renal Disease: Analysis of 97 Cases

    International Nuclear Information System (INIS)

    Han, Seung Min; Chung, Tae Woong; Yoon, Woong

    2007-01-01

    To evaluate the diagnostic efficacy and complications of ultrasound-guided percutaneous renal biopsy using automatic biopsy gun in patients with pediatric diffuse renal disease. Using an 18G automatic biopsy gun, biopsies were performed on 97 pediatric patients with clinically suspicious diffuse renal disease. The acquired tissue specimens were analyzed by photomicroscopy, immunofluorescence, and electron microscopy to support the diagnosis. In the 97 biopsies, the success of the histologic diagnosis, number of glomeruli, and complication rates were retrospectively evaluated by analyzing the variable exams and clinical records. Adequate tissue for histologic diagnosis was obtained in 91 of 97 biopsies (94%) and the mean number of glomeruli was 9.6. Complications such as minute pain, gross hematuria, and small perirenal hematoma presented in 22 of the 97 biopsies (23%), all of which either improved within 5-72 hours or did not need specific treatment. Ultrasound-guided percutaneous renal biopsy using 18G automatic biopsy gun is an effective and safe method for the histologic diagnosis of pediatric diffuse renal disease without any major complication

  9. The biopsy of the boar testes using ultrasonographic examination

    Directory of Open Access Journals (Sweden)

    Laima Liepa

    2014-03-01

    Full Text Available The biopsy of live animal testes is an important clinical manipulation to control spermatogenesis and reproductive system pathologies. The aim was to develop a method of boar testes biopsy using a biopsy gun with ultrasound guidance and to investigate the influence of this procedure on the boar testes parenchyma and quality of ejaculate. The biopsy was carried out in six 8-month-old boars. Fourteen days prior to and 21 days after biopsy, the quality of ejaculate was examined (weight of ejaculate; concentration and motility of spermatozoa with a seven-day intervals. Ultrasound images of the testes parenchyma were recorded three times: directly before and 15 minutes after the biopsy, then 21 days after the procedure. The testes biopsies of generally anesthetized boars were performed with the biopsy gun for needle biopsy with a 12cm long, disposable 16-gauge needle 1.8mm in diameter (Vitesse through 1cm skin incision in the depth of 1.2-1.6cm of parenchyma. Fifteen minutes after the biopsy, macroscopic injures of the parenchyma of all the boar testes were not detected in the ultrasound image. Twenty one days after biopsy, the hyperechogenic line 0.1-0.2cm in diameter was seen in the testes parenchyma of six boars in the depth of 1.2-1.6cm. The biopsy of boar testes did not influence the quality of boars ejaculate. The ultrasonographic examination of boar testicles before the biopsy reduced possibilities to traumatize large blood vessels of the testes. A perfect boar testicular biopsy was easy to perform using ultrasonographic examination in the pigsty conditions.

  10. New patient pathway using vacuum-assisted biopsy reduces diagnostic surgery for B3 lesions

    International Nuclear Information System (INIS)

    Rajan, S.; Shaaban, A.M.; Dall, B.J.G.; Sharma, N.

    2012-01-01

    Aim: To assess the clinical impact of a new patient management pathway incorporating vacuum-assisted biopsy for lesions of uncertain malignant potential (B3). Materials and methods: A retrospective analysis was undertaken of all B3 lesions on core biopsy in the pathology database from April 2008 to April 2010. Outcome measures assessed included final histological diagnosis, frequency of diagnostic surgical biopsy, and impact on management. Results: In the old pathway, there were 95 B3 lesions, of which 14% (13/95) were planned for vacuum-assisted biopsy and 86% (82/95) for surgical biopsy. In the new pathway, there were 94 B3 lesions, of which 68% (64/94) were planned for vacuum-assisted biopsy and 32% (30/94) for surgical biopsy. Following further sampling with vacuum-assisted biopsy, only 13% of patients required diagnostic surgical biopsy and in 25% of cases, a preoperative diagnosis of carcinoma was reached allowing patients to proceed to therapeutic surgery. Conclusion: The new pathway has reduced the number of benign diagnostic surgical biopsies performed and increased the preoperative diagnosis of breast cancer.

  11. Is percutaneous fine-needle biopsy a hazard? An update

    International Nuclear Information System (INIS)

    Smith, E.H.

    1987-01-01

    Fine-needle biopsy (FNB) has become a commonplace diagnostic procedure in most radiology departments with the assumption that risks are nonexistent. Animal experiments conclusively indicate the leakage of tumor cells after biopsy, but clinical evidence appears to point to a paucity of complications. In a prior review of the literature, two needle tract seedings (NTS) and two fatalities after FNB were discovered. A questionnaire at that time uncovered three more cases of NTS and four deaths. An updated literature search and questionnaire showed an additional 14 cases of NTS and nine deaths. An analysis of the date are reported

  12. Diagnostic accuracy of pre-treatment biopsy for grading cutaneous mast cell tumours in dogs.

    Science.gov (United States)

    Shaw, T; Kudnig, S T; Firestone, S M

    2018-06-01

    Mast cell tumours (MCTs) are common tumours of the canine skin, and are estimated to represent up to 20% of all skin tumours in dogs. Tumour grade has a major impact on the incidence of local recurrence and metastatic potential. In addition to helping the clinician with surgical planning, knowledge of the tumour grade also assists in proper prognostication and client education. For pre-treatment biopsies to be useful, there must exist a high level of correlation between the histopathological grade obtained from the pre-treatment biopsy and the actual histopathological grade from the excisional biopsy. The aim of this study was to determine concordance of tumour grade between various biopsy techniques (wedge, punch, needle core) and the "gold standard" excisional biopsy method. We found an overall concordance rate of 96% based on the Patnaik grading system, and an overall concordance rate of 92% based on the Kiupel grading system. The accuracy of the various biopsy techniques (wedge, punch and needle core) when compared with excisional biopsy was 92%, 100% and 100%, respectively, based on the Patnaik grading system, and 90%, 95% and 100%, respectively, based on the Kiupel grading system. Of the cases with discordant results, the pre-treatment biopsies tended to underestimate the grade of the tumour. Based on these results, we conclude that pre-treatment biopsies are sufficiently accurate for differentiating low-grade from high-grade MCTs, regardless of biopsy technique or tumour location. © 2017 John Wiley & Sons Ltd.

  13. Transition from blastomere to trophectoderm biopsy: comparing two preimplantation genetic testing for aneuploidies strategies.

    Science.gov (United States)

    Coll, Lluc; Parriego, Mònica; Boada, Montserrat; Devesa, Marta; Arroyo, Gemma; Rodríguez, Ignacio; Coroleu, Bonaventura; Vidal, Francesca; Veiga, Anna

    2018-05-25

    SummaryShortly after the implementation of comprehensive chromosome screening (CCS) techniques for preimplantation genetic testing for aneuploidies (PGT-A), the discussion about the transition from day 3 to blastocyst stage biopsy was initiated. Trophectoderm biopsy with CCS is meant to overcome the limitations of cleavage-stage biopsy and single-cell analysis. The aim of this study was to assess the results obtained in our PGT-A programme after the implementation of this new strategy. Comparisons between the results obtained in 179 PGT-A cycles with day 3 biopsy (D+3) and fresh embryo transfer, and 204 cycles with trophectoderm biopsy and deferred (frozen-thawed) embryo transfer were established. Fewer embryos were biopsied and a higher euploidy rate was observed in the trophectoderm biopsy group. No differences in implantation (50.3% vs. 61.4%) and clinical pregnancy rate per transfer (56.1% vs. 65.3%) were found. Although the mean number of euploid embryos per cycle did not differ between groups (1.5 ± 1.7 vs. 1.7 ± 1.8), the final number of euploid blastocysts available for transfer per cycle was significantly higher in the trophectoderm biopsy group (1.1 ± 1.3 vs. 1.7 ± 1.8). This factor led to an increased cumulative live birth rate in this last group (34.1% vs. 44.6%). Although both strategies can offer good results, trophectoderm biopsy offers a more robust diagnosis and the intervention is less harmful for the embryos so more euploid blastocysts are finally available for transfer and/or vitrification.

  14. Diode laser for excisional biopsy of peripheral ossifying fibroma

    Directory of Open Access Journals (Sweden)

    Kirti Chawla

    2014-01-01

    Full Text Available Peripheral Ossifying Fibroma is one of the commonest occurring reactive lesions on gingiva. It is associated with local irritational factors and often interferes with speech, mastication and maintenance of oral hygiene, in addition to being aesthetically unpleasant. It is usually treated with surgical excision using scalpel and removal of irritational factors, often resulting in mucogingival defect. Other modalities such as radiosurgery and electrocautery have also been used for its management, but they cause changes in microarchitecture of biopsy specimen, altering the histologic picture for true diagnosis. We are presenting a case of excisional biopsy of this lesion in an adult female using a diode laser with excellent post-operative results, without affecting microarchitecture of biopsy specimen. The patient is being followed for last 1 year and no sign of recurrence has been found. A diode laser may offer a good alternative modality for management of such cases.

  15. Complete removal of a breast mass by US-guided mammotome biopsy: histologic assessment by marginal sampling

    International Nuclear Information System (INIS)

    Kim, Youn Jeong; Choi, Hye Young; Moon, Byung In; Lee, Shi Nae

    2005-01-01

    The aim of this study was to assess whether the complete removal of a breast mass using ultrasound (US) guided mammotome biopsy was successful using a marginal biopsy after insuring the total visual excision of the breast mass on US images. The relationship of complete breast mass removal, and the hematoma, mass size and shape were also evaluated. A US guided mammotome biopsy was performed in a total of 136 cases in 133 patients, with marginal biopsies also added when the complete removal of breast mass had been identified by sonography. The results of the marginal biopsies were serially dividing into three groups, as follows: group I were the cases in the initial 6 months, group II after the initial 6 months and group III having undergone two marginal biopsies. The marginal biopsies were performed in four directions around the probe, with 'marginal positivity' defined as the same histopathological findings to that of the main mass in at least one direction. A statistical analysis was also used to evaluate between the marginal positivity and the hematoma, mass size and shape. The marginal positivities of groups I, II and III were 48.8, 29.4 and 45.5%, respectively. The marginal positivity of those with a lobular shaped mass was significantly higher (ρ = 0.0121) than those with round or oval shaped masses (61.5 vs 33.7 vs 50%), but showed no statistical relationship with hematoma size of the lesions. Although the lesions were removed by US using a US-guided mammotome biopsy, many residual lesions were still histologically present in the marginal samplings, especially in the lobular shaped masse

  16. Documenting the location of systematic transrectal ultrasound-guided prostate biopsies: correlation with multi-parametric MRI.

    Science.gov (United States)

    Turkbey, Baris; Xu, Sheng; Kruecker, Jochen; Locklin, Julia; Pang, Yuxi; Shah, Vijay; Bernardo, Marcelino; Baccala, Angelo; Rastinehad, Ardeshir; Benjamin, Compton; Merino, Maria J; Wood, Bradford J; Choyke, Peter L; Pinto, Peter A

    2011-03-29

    During transrectal ultrasound (TRUS)-guided prostate biopsies, the actual location of the biopsy site is rarely documented. Here, we demonstrate the capability of TRUS-magnetic resonance imaging (MRI) image fusion to document the biopsy site and correlate biopsy results with multi-parametric MRI findings. Fifty consecutive patients (median age 61 years) with a median prostate-specific antigen (PSA) level of 5.8 ng/ml underwent 12-core TRUS-guided biopsy of the prostate. Pre-procedural T2-weighted magnetic resonance images were fused to TRUS. A disposable needle guide with miniature tracking sensors was attached to the TRUS probe to enable fusion with MRI. Real-time TRUS images during biopsy and the corresponding tracking information were recorded. Each biopsy site was superimposed onto the MRI. Each biopsy site was classified as positive or negative for cancer based on the results of each MRI sequence. Sensitivity, specificity, and receiver operating curve (ROC) area under the curve (AUC) values were calculated for multi-parametric MRI. Gleason scores for each multi-parametric MRI pattern were also evaluated. Six hundred and 5 systemic biopsy cores were analyzed in 50 patients, of whom 20 patients had 56 positive cores. MRI identified 34 of 56 positive cores. Overall, sensitivity, specificity, and ROC area values for multi-parametric MRI were 0.607, 0.727, 0.667, respectively. TRUS-MRI fusion after biopsy can be used to document the location of each biopsy site, which can then be correlated with MRI findings. Based on correlation with tracked biopsies, T2-weighted MRI and apparent diffusion coefficient maps derived from diffusion-weighted MRI are the most sensitive sequences, whereas the addition of delayed contrast enhancement MRI and three-dimensional magnetic resonance spectroscopy demonstrated higher specificity consistent with results obtained using radical prostatectomy specimens.

  17. CT guided biopsies as a part of the investigations in findings in the lung and thorax wall

    DEFF Research Database (Denmark)

    Vagn-Hansen, Chris Aksel; Pedersen, Malene Roland Vils; Rafaelsen, Søren Rafael

    was performed. Results: In 86 % of the biopsies, the tissue material was found sufficient. In 32 % of the biopsies there was a complication, mostly pneumothorax (30%), but in only 15 % of the 520 cases chest drainage was needed. There was one death in a known cancer patient with severe reduced lung and cardiac...... function. Patients with more than 10 cigarette pack years had a complication risk twice as high compared to patients with less pack years. We found that the risk of pneumothorax rises the further the lesion is from the skin surface, the smaller the lesions are and when the patient is biopsied in a lateral...... position. We found a higher risk of complications in females. Conclusion: CT guided biopsy is an excellent tool in the analysis of lesions in the lungs. This study clearly shows that the risk of developing a pneumothorax is significantly higher among smokers and former smokers with more than 10 pack years....

  18. Follow-up Sonography after Sonoguided Renal Biopsy

    International Nuclear Information System (INIS)

    Kim, Hyung Soo; Park, Cheol Min; Cha, In Ho

    1996-01-01

    To assess ultrasonographic findings and clinical significance after renal biopsy. 174 cases of post-biopsy sonography were studied retrospectively. We classified post-biopsy hematoma on the basis of their size as small (thickness less than 1 cm, length less than 3cm), medium (thickness less than 1cm, length greater than 3 cm), large (thickness greater than 1 cm, length greater than 3 cm). We also compared bleeding parameters (prothrombin time, partial thromboplastin time) and renal function in both cases which had hematoma or not. Total 33 hematomas were found (19%). Small hematoma was observed in 14 cases, medium hematoma in 16 cases, large hematoma in 3 cases. Severe complications requiring prompt therapy occurred in 1 case(0.6%). In 6 cases hematocrit fell by more than 4%, all of these hematomas were observed on US. Severe complications after sonoguided renal biopsy were rare. There was poor correlation between prebiopsybleeding parameter, renal function and post-biopsy hematomas. And sonography is considered as adequate method for follow up of post-biopsy hematoma

  19. Sentinel node biopsy in penile cancer

    DEFF Research Database (Denmark)

    Jakobsen, J. K.; Krarup, K. P.; Sommer, P.

    2015-01-01

    INTRODUCTION & OBJECTIVES: Nodal involvement is a strong prognosticator in penile cancer and lymph node staging is crucial. Sentinel node biopsy (SNB) has proven a useful staging tool with few complications, but evidence rely mostly on single institution publications with a short follow-up. In th......INTRODUCTION & OBJECTIVES: Nodal involvement is a strong prognosticator in penile cancer and lymph node staging is crucial. Sentinel node biopsy (SNB) has proven a useful staging tool with few complications, but evidence rely mostly on single institution publications with a short follow...... died from complications. CONCLUSIONS: To our knowledge, this is the first complete national study on sentinel node biopsy. Penile cancer sentinel node biopsy with a close follow-up is a reliable lymph node staging and has few complications in a national multicentre setting. Inguinal lymph node...

  20. Computed tomography guidance for skeletal biopsy

    International Nuclear Information System (INIS)

    Frager, D.H.; Goldman, M.J.; Elkin, C.M.; Cynamon, J.; Leeds, N.E.; Seimon, L.P.; Habermann, E.T.; Schreiber, K.; Freeman, L.M.

    1987-01-01

    Computed tomographic (CT) guided biopsy and abscess drainage of multiple organ systems have been well described. Reports of spinal and skeletal applications have been less common. This study describes the use of CT guidance in the biopsy of various skeletal lesions in 46 patients. Forty-one patients had skinny needle aspirations (18 or 22 gauge) and 23 patients had trephine core biopsies. Sites of the lesions included: thoracic spine - 15 patients, lumbosacral spine - 17 patients, bony pelvis - 6 patients, rib - 2 patients, and long bones - 6 patients. Fast scanners capable of rapid image reconstruction have overcome many constraints. With CT guidance, the physician who performs the procedure receives virtually no ionizing radiation. The exact location of the needle tip is accurately visualized in relation to the lesion being biopsied and to the vital organs. (orig.)

  1. Potential impact of the MR spectroscopic cancer blood test on reducing the need for lung biopsy

    International Nuclear Information System (INIS)

    Simon, M.; Fossel, E.T.

    1989-01-01

    Lung biopsies are generally performed to identify or rule out malignancy. A clinical presumption of lung malignancy without biopsy proof may result in unjustified surgery. The authors sought to test the value of the MR cancer blood test (CBT) recently described. They obtained prebiopsy blood samples (2 mL) from 65 patients undergoing lung biopsy for radiologically identified lesions. The CBT was performed blinded, and the result was then compared with the pathologic diagnosis obtained from biopsy. Results are presented

  2. Risk score predicts high-grade prostate cancer in DNA-methylation positive, histopathologically negative biopsies.

    Science.gov (United States)

    Van Neste, Leander; Partin, Alan W; Stewart, Grant D; Epstein, Jonathan I; Harrison, David J; Van Criekinge, Wim

    2016-09-01

    Prostate cancer (PCa) diagnosis is challenging because efforts for effective, timely treatment of men with significant cancer typically result in over-diagnosis and repeat biopsies. The presence or absence of epigenetic aberrations, more specifically DNA-methylation of GSTP1, RASSF1, and APC in histopathologically negative prostate core biopsies has resulted in an increased negative predictive value (NPV) of ∼90% and thus could lead to a reduction of unnecessary repeat biopsies. Here, it is investigated whether, in methylation-positive men, DNA-methylation intensities could help to identify those men harboring high-grade (Gleason score ≥7) PCa, resulting in an improved positive predictive value. Two cohorts, consisting of men with histopathologically negative index biopsies, followed by a positive or negative repeat biopsy, were combined. EpiScore, a methylation intensity algorithm was developed in methylation-positive men, using area under the curve of the receiver operating characteristic as metric for performance. Next, a risk score was developed combining EpiScore with traditional clinical risk factors to further improve the identification of high-grade (Gleason Score ≥7) cancer. Compared to other risk factors, detection of DNA-methylation in histopathologically negative biopsies was the most significant and important predictor of high-grade cancer, resulting in a NPV of 96%. In methylation-positive men, EpiScore was significantly higher for those with high-grade cancer detected upon repeat biopsy, compared to those with either no or low-grade cancer. The risk score resulted in further improvement of patient risk stratification and was a significantly better predictor compared to currently used metrics as PSA and the prostate cancer prevention trial (PCPT) risk calculator (RC). A decision curve analysis indicated strong clinical utility for the risk score as decision-making tool for repeat biopsy. Low DNA-methylation levels in PCa-negative biopsies led

  3. A Single-Institution Experience in Percutaneous Image-Guided Biopsy of Malignant Pleural Mesothelioma

    International Nuclear Information System (INIS)

    Welch, B. T.; Eiken, P. W.; Atwell, T. D.; Peikert, T.; Yi, E. S.; Nichols, F.; Schmit, G. D.

    2017-01-01

    PurposeMesothelioma has been considered a difficult pathologic diagnosis to achieve via image-guided core needle biopsy. The purpose of this study was to assess the diagnostic sensitivity of percutaneous image-guided biopsy for diagnosis of pleural mesothelioma.Materials and MethodsRetrospective review was performed to identify patients with a confirmed diagnosis of pleural mesothelioma and who underwent image-guided needle biopsy between January 1, 2002, and January 1, 2016. Thirty-two patients with pleural mesothelioma were identified and included for analysis in 33 image-guided biopsy procedures. Patient, procedural, and pathologic characteristics were recorded. Complications were characterized via standardized nomenclature [Common Terminology for Clinically Adverse Events (CTCAE)].ResultsPercutaneous image-guided biopsy was associated with an overall sensitivity of 81%. No CTCAE clinically significant complications were observed. No image-guided procedures were complicated by pneumothorax or necessitated chest tube placement. No patients had tumor seeding of the biopsy tract.ConclusionPercutaneous image-guided biopsy can achieve high sensitivity for pathologic diagnosis of pleural mesothelioma with a low procedural complication rate, potentially obviating need for surgical biopsy.

  4. A Single-Institution Experience in Percutaneous Image-Guided Biopsy of Malignant Pleural Mesothelioma

    Energy Technology Data Exchange (ETDEWEB)

    Welch, B. T., E-mail: Welch.brian@mayo.edu; Eiken, P. W.; Atwell, T. D. [Mayo Clinic, Department of Radiology (United States); Peikert, T. [Mayo Clinic, Department of Pulmonary and Critical Care Medicine (United States); Yi, E. S. [Mayo Clinic, Department of Pathology (United States); Nichols, F. [Mayo Clinic, Department of Thoracic Surgery (United States); Schmit, G. D. [Mayo Clinic, Department of Radiology (United States)

    2017-06-15

    PurposeMesothelioma has been considered a difficult pathologic diagnosis to achieve via image-guided core needle biopsy. The purpose of this study was to assess the diagnostic sensitivity of percutaneous image-guided biopsy for diagnosis of pleural mesothelioma.Materials and MethodsRetrospective review was performed to identify patients with a confirmed diagnosis of pleural mesothelioma and who underwent image-guided needle biopsy between January 1, 2002, and January 1, 2016. Thirty-two patients with pleural mesothelioma were identified and included for analysis in 33 image-guided biopsy procedures. Patient, procedural, and pathologic characteristics were recorded. Complications were characterized via standardized nomenclature [Common Terminology for Clinically Adverse Events (CTCAE)].ResultsPercutaneous image-guided biopsy was associated with an overall sensitivity of 81%. No CTCAE clinically significant complications were observed. No image-guided procedures were complicated by pneumothorax or necessitated chest tube placement. No patients had tumor seeding of the biopsy tract.ConclusionPercutaneous image-guided biopsy can achieve high sensitivity for pathologic diagnosis of pleural mesothelioma with a low procedural complication rate, potentially obviating need for surgical biopsy.

  5. Clinical utility of the Prostate Health Index (phi) for biopsy decision management in a large group urology practice setting.

    Science.gov (United States)

    White, Jay; Shenoy, B Vittal; Tutrone, Ronald F; Karsh, Lawrence I; Saltzstein, Daniel R; Harmon, William J; Broyles, Dennis L; Roddy, Tamra E; Lofaro, Lori R; Paoli, Carly J; Denham, Dwight; Reynolds, Mark A

    2018-04-01

    Deciding when to biopsy a man with non-suspicious DRE findings and tPSA in the 4-10 ng/ml range can be challenging, because two-thirds of such biopsies are typically found to be benign. The Prostate Health Index (phi) exhibits significantly improved diagnostic accuracy for prostate cancer detection when compared to tPSA and %fPSA, however only one published study to date has investigated its impact on biopsy decisions in clinical practice. An IRB approved observational study was conducted at four large urology group practices using a physician reported two-part questionnaire. Physician recommendations were recorded before and after receiving the phi test result. A historical control group was queried from each site's electronic medical records for eligible men who were seen by the same participating urologists prior to the implementation of the phi test in their practice. 506 men receiving a phi test were prospectively enrolled and 683 men were identified for the historical control group (without phi). Biopsy and pathological findings were also recorded for both groups. Men receiving a phi test showed a significant reduction in biopsy procedures performed when compared to the historical control group (36.4% vs. 60.3%, respectively, P phi score impacted the physician's patient management plan in 73% of cases, including biopsy deferrals when the phi score was low, and decisions to perform biopsies when the phi score indicated an intermediate or high probability of prostate cancer (phi ≥36). phi testing significantly impacted the physician's biopsy decision for men with tPSA in the 4-10 ng/ml range and non-suspicious DRE findings. Appropriate utilization of phi resulted in a significant reduction in biopsy procedures performed compared to historical patients seen by the same participating urologists who would have met enrollment eligibility but did not receive a phi test.

  6. Can Confirmatory Biopsy be Omitted in Prostate Cancer Active Surveillance Patients with Favorable Diagnostic Features?

    Science.gov (United States)

    Satasivam, Prassannah; Poon, Bing Ying; Ehdaie, Behfar; Vickers, Andrew J.; Eastham, James A.

    2016-01-01

    Purpose We evaluated whether initial diagnostic parameters could predict the confirmatory biopsy result in patients initiating active surveillance for prostate cancer, to determine whether some men at low risk of reclassification could be spared unnecessary biopsy. Materials and Methods The cohort included 392 men with Gleason 6 prostate cancer on initial biopsy undergoing confirmatory biopsy. We used univariate and multivariable logistic regression to assess if high-grade cancer (Gleason ≥ 7) on confirmatory biopsy could be predicted from initial diagnostic parameters (prostate-specific antigen density, magnetic resonance imaging result, percent positive cores, percent cancer in positive cores, and total tumor length). Results Median age was 62 years (IQR 56–66) and 47% of patients were found to have a dominant or focal lesion on magnetic resonance imaging. Of the 392 patients, 44 (11%) were found to have high-grade cancer on confirmatory biopsy, among whom 39 had 3+4, 1 had 4+3, 3 had Gleason 8, and 1 patient had Gleason 9 disease. All predictors were significantly associated with high-grade cancer at confirmatory biopsy on univariate analysis. However, in the multivariable model only prostate-specific antigen density and total tumor length were significantly associated (AUC of 0.85). Using this model to select patients for confirmatory biopsy would generally provide a higher net benefit than performing confirmatory biopsy in all patients, across a wide range of threshold probabilities. Conclusion If externally validated, a model based on initial diagnostic criteria could be used to avoid confirmatory biopsy in many patients initiating active surveillance. PMID:26192258

  7. Cost-effectiveness of MR Imaging-guided Strategies for Detection of Prostate Cancer in Biopsy-Naive Men.

    Science.gov (United States)

    Pahwa, Shivani; Schiltz, Nicholas K; Ponsky, Lee E; Lu, Ziang; Griswold, Mark A; Gulani, Vikas

    2017-10-01

    Purpose To evaluate the cost-effectiveness of multiparametric diagnostic magnetic resonance (MR) imaging examination followed by MR imaging-guided biopsy strategies in the detection of prostate cancer in biopsy-naive men presenting with clinical suspicion of cancer for the first time. Materials and Methods A decision-analysis model was created for biopsy-naive men who had been recommended for prostate biopsy on the basis of abnormal digital rectal examination results or elevated prostate-specific antigen levels (age groups: 41-50 years, 51-60 years, and 61-70 years). The following three major strategies were evaluated: (a) standard transrectal ultrasonography (US)-guided biopsy; (b) diagnostic MR imaging followed by MR imaging-targeted biopsy, with no biopsy performed if MR imaging findings were negative; and (c) diagnostic MR imaging followed by MR imaging-targeted biopsy, with a standard biopsy performed when MR imaging findings were negative. The following three MR imaging-guided biopsy strategies were further evaluated in each MR imaging category: (a) biopsy with cognitive guidance, (b) biopsy with MR imaging/US fusion guidance, and (c) in-gantry MR imaging-guided biopsy. Model parameters were derived from the literature. The primary outcome measure was net health benefit (NHB), which was measured as quality-adjusted life-years (QALYs) gained or lost by investing resources in a new strategy compared with a standard strategy at a willingness-to-pay (WTP) threshold of $50 000 per QALY gained. Probabilistic sensitivity analysis was performed by using Monte Carlo simulations. Results Noncontrast MR imaging followed by cognitively guided MR biopsy (no standard biopsy if MR imaging findings were negative) was the most cost-effective approach, yielding an additional NHB of 0.198 QALY compared with the standard biopsy approach. Noncontrast MR imaging followed by in-gantry MR imaging-guided biopsy (no standard biopsy if MR imaging findings were negative) led to the

  8. Significance of endoscopic biopsy after preoperative irradiation therapy for rectal cancer

    Energy Technology Data Exchange (ETDEWEB)

    Takiguchi, Nobuhiro; Sarashina, Hiromi; Saito, Norio; Nunomura, Masao; Kohda, Keishi; Nakajima, Nobuyuki (Chiba Univ. (Japan). School of Medicine)

    1994-05-01

    To evaluate the utility of endoscopic biopsy before and after preoperative irradiation therapy for rectal cancer, we examined histologically both biopsy specimens and resected materials of forty-three patients. Two pieces of biopsy materials were taken both before and after irradiation therapy (total dose 42.6 Gy) from the marginal wall of the tumor, cavity and transitional mucosa, respectively. In biopsy specimens, according to the degree of degeneration of cancer cells, cases with remarkable changes of nucleus, nucleolus, and cytoplasm due to irradiation were classified into the severely degenerated group. According to the histological examinations of resected materials, twenty-four cases were under Grade 1b (Gr I), and nineteen cases were over Grade 2 (Gr II). The rates of cancer cells found in biopsy materials after irradiation were 91.7% in Gr I and were 47.4% in Gr II, respectively (p<0.01). Among the cases, 54.5% in Gr I and 100% in Gr II belonged to the severely degenerated group (p<0.05). Transitional mucosas were not greatly damaged by irradiation. As a result, the greater the irradiation effect was, the fewer cancer cells were found and the more degenerated cancer cells were found in biopsy specimens. But the rate of severely degenerated cells found in the biopsy specimens of little effect cases was high. So it was thought to be too difficult to predict the histological radiation effect of resected specimens from only biopsy specimens. (author).

  9. Die Biopsie von Knochen- und Weichteiltumoren

    OpenAIRE

    Fuchs, B

    2008-01-01

    Technisch stellt die Biopsie von Knochen- und Weichteiltumoren einen simplen Akt dar, intellektuell aber ist die Planung einer Biopsie höchst anspruchsvoll. Zu häufig werden heutzutage immer noch Biopsien unsachgemäss durchgeführt, so dass die Behandlung - im besten Fall - erschwert wird. Eine unsachgemäss durchgeführte Biopsie führt häufig zu negativen funktionellen Konsequenzen für den Patienten, im schlimmsten Fall kann es die Prognose direkt beeinträchtigen. Aus diesem Grund soll...

  10. Percutaneous transluminal biopsy using 7F forceps for diagnosing malignant biliary obstruction

    Energy Technology Data Exchange (ETDEWEB)

    Bahn, Young Eun; Kim, Young Hwan; An, Eun Jung; Kim, See Hyung [Keimyung Univ. College of Medicine, Daegu (Korea, Republic of)

    2012-07-15

    To evaluate the usefulness of the percutaneous transluminal biopsy using 7-F forceps for diagnosing malignant biliary obstruction. One hundred and seven consecutive patients with obstructive jaundice underwent transluminal forceps biopsy. The lesions involved the common bile duct (n = 33), common hepatic duct (n = 13), hilum (n = 17), right or left intrahepatic bile duct (n = 32), multiple sites (extra and intrahepatic ducts, n = 7), or anastomotic sites (n = 5). In each patient, an average of three specimens was taken with 7F biopsy forceps through a transhepatic biliary drainage tract. The final diagnosis was confirmed with pathologic findings, or a clinical and radiologic follow up. The final diagnoses showed malignancies in 75 patients and benign biliary obstructions in 32 patients. Pathologic classifications of malignancies established by forceps biopsy included 67 adenocarcinomas, 1 adenosquamous cell carcinoma, and 1 hepatocelluar carcinoma. There were 6 false-negative diagnoses. The diagnostic performance of transluminal forceps biopsy in malignant biliary obstruction had a sensitivity of 92%, specificity of 100%, positive predictive value of 100%, a negative predictive value of 84.2%, and an accuracy of 94.2%. Percutaneous transluminal forceps biopsy is a safe procedure that is easy to perform through a transhepatic biliary drainage tract. It is a highly accurate technique for diagnosing malignant biliary obstructions.

  11. Effect on hemostasis of an absorbable hemostatic gelatin sponge after transrectal prostate needle biopsy

    Directory of Open Access Journals (Sweden)

    Kohei Kobatake

    2015-04-01

    Full Text Available Objectives To examine the usefulness of an absorbable hemostatic gelatin sponge for hemostasis after transrectal prostate needle biopsy. Subjects and Methods The subjects comprised 278 participants who underwent transrectal prostate needle biopsy. They were randomly allocated to the gelatin sponge insertion group (group A: 148 participants and to the non-insertion group (group B: 130 participants. In group A, the gelatin sponge was inserted into the rectum immediately after biopsy. A biopsy-induced hemorrhage was defined as a case in which a subject complained of bleeding from the rectum, and excretion of blood clots was confirmed. A blood test was performed before and after biopsy, and a questionnaire survey was given after the biopsy. Results Significantly fewer participants in group A required hemostasis after biopsy compared to group B (3 (2.0% vs. 11 (8.5%, P=0.029. The results of the blood tests and the responses from the questionnaire did not differ significantly between the two groups. In multivariate analysis, only “insertion of a gelatin sponge into the rectum” emerged as a significant predictor of hemostasis. Conclusion Insertion of a gelatin sponge into the rectum after transrectal prostate needle biopsy significantly increases hemostasis without increasing patient symptoms, such as pain and a sense of discomfort.

  12. Feasibility and effectiveness of image-guided percutaneous biopsy of the urinary bladder.

    Science.gov (United States)

    Butros, Selim Reha; McCarthy, Colin James; Karaosmanoğlu, Ali Devrim; Shenoy-Bhangle, Anuradha S; Arellano, Ronald S

    2015-08-01

    To evaluate the indications, technique, results, and complications of image-guided percutaneous biopsy of the urinary bladder. This retrospective study included 15 patients (10 male, 5 female) who underwent image-guided percutaneous biopsy of the urinary bladder between January 1999 and December 2013. The medical records, imaging studies, procedural details, and long-term follow-up of each patient were reviewed in detail to assess the feasibility of percutaneous bladder biopsy. Ten patients had focal bladder masses and 5 patients had asymmetric or diffuse bladder wall thickening. Eleven patients had either negative or unsatisfactory cystoscopies prior to the biopsy. Percutaneous biopsies were performed under computed tomography guidance in 12 patients and ultrasound in 3 patients. All procedures were technically successful and there were no procedural complications. Malignancy was confirmed in 8 patients, among whom 6 had transitional cell carcinoma, 1 cervical cancer, and 1 prostate cancer metastasis. Seven patients had a benign diagnosis, including 3 that were later confirmed by pathology following surgery and 2 patients with a false-negative result. The overall sensitivity was 80% and accuracy was 87%. Image-guided percutaneous biopsy of the urinary bladder is a safe and technically feasible procedure with a high sensitivity and accuracy rate. Although image-guided bladder biopsy is an uncommon procedure, it should be considered in selected cases when more traditional methods of tissue sampling are either not possible or fail to identify abnormalities detected by cross-sectional imaging.

  13. Prostate Cancer Diagnosed After Repeat Biopsies Have a Favorable Pathological Outcome but Similar Recurrence Rate

    Science.gov (United States)

    Lopez-Corona, Ernesto; Ohori, Makoto; Wheeler, Thomas M.; Reuter, Victor E.; Scardino, Peter T.; Kattan, Michael W.; Eastham, James A.

    2007-01-01

    Purpose We investigated whether repeat prostate biopsies are associated with more favorable prognoses, less extensive disease or higher rates of IC in patients who are ultimately diagnosed with prostate cancer and treated with RRP. Materials and Methods We examined standard clinical and pathological data on 1,357 patients treated with RRP from 1983 to 2001. In addition, we noted the rate of IC in a subgroup of 847 patients in whom tumor volume was measured. Results Cancer was found in 1,042 patients (77%) at the first biopsy, in 227 (17%) at the second biopsy, in 59 (4%) at the third biopsy and in 29 (2%) at the fourth or later biopsy. Patients with 2 or greater biopsies had a higher rate of clinical T1c stage cancer and larger prostates than patients with only 1 biopsy (each p <0.0001). After RRP patients with 1 biopsy had a lower rate of organ confined tumors (61% vs 75%, p <0.0001), and a higher rate of extracapsular extension, seminal vesicle invasion, lymph node metastases and Gleason sum 7 or greater than other patients. IC was found in 10% of patients with 1 biopsy and 18% of those with 2 or greater biopsies (p = 0.018). Despite these more favorable pathological outcomes there was no difference in biochemical recurrence rate. Conclusions Although we found that a greater number of biopsies was related to a better pathological outcome after RRP, the number of biopsies did not predict disease recurrence. The increasing number of biopsies currently being performed, especially in patients with larger prostates, likely results in higher rates of IC. PMID:16469581

  14. CT Fluoroscopy-Guided Lung Biopsy with Novel Steerable Biopsy Canula: Ex-Vivo Evaluation in Ventilated Porcine Lung Explants

    International Nuclear Information System (INIS)

    Schaefer, Philipp J.; Fabel, Michael; Bolte, Hendrik; Schaefer, Fritz K. W.; Jahnke, Thomas; Heller, Martin; Lammer, Johannes; Biederer, Juergen

    2010-01-01

    The purpose was to evaluate ex-vivo a prototype of a novel biopsy canula under CT fluoroscopy-guidance in ventilated porcine lung explants in respiratory motion simulations. Using an established chest phantom for porcine lung explants, n = 24 artificial lesions consisting of a fat-wax-Lipiodol mixture (approx. 70HU) were placed adjacent to sensible structures such as aorta, pericardium, diaphragm, bronchus and pulmonary artery. A piston pump connected to a reservoir beneath a flexible silicone reconstruction of a diaphragm simulated respiratory motion by rhythmic inflation and deflation of 1.5 L water. As biopsy device an 18-gauge prototype biopsy canula with a lancet-like, helically bended cutting edge was used. The artificial lesions were punctured under CT fluoroscopy-guidance (SOMATOM Sensation 64, Siemens, Erlangen, Germany; 30mAs/120 kV/5 mm slice thickness) implementing a dedicated protocol for CT fluoroscopy-guided lung biopsy. The mean-diameter of the artificial lesions was 8.3 ± 2.6 mm, and the mean-distance of the phantom wall to the lesions was 54.1 ± 13.5 mm. The mean-displacement of the lesions by respiratory motion was 14.1 ± 4.0 mm. The mean-duration of CT fluoroscopy was 9.6 ± 5.1 s. On a 4-point scale (1 = central; 2 = peripheral; 3 = marginal; 4 = off target), the mean-targeted precision was 1.9 ± 0.9. No misplacement of the biopsy canula affecting adjacent structures could be detected. The novel steerable biopsy canula proved to be efficient in the ex-vivo set-up. The chest phantom enabling respiratory motion and the steerable biopsy canula offer a feasible ex-vivo system for evaluating and training CT fluoroscopy-guided lung biopsy adapted to respiratory motion.

  15. Risk of disseminated intravascular coagulation in patients undergoing US-guided transperineal prostatic biopsy

    International Nuclear Information System (INIS)

    Stella, M.S.; Comparato, D.; Camici, M.; Evangelisti, L.; Gaudio, V.; De Negri, F.; Talarico, L.; Giusti, C.; Morelli, G.

    1991-01-01

    Disseminated intravascular coagulation (DIC) is a severe life-threatening acute bleeding disorder. Traumatized tissues, tumors, necrotic tissues, or bacterial endotoxines release similar material in the blood to the tissutal factors activating the coagulation cascade. This preliminary study was aimed at verifying the risk of DIV in patients undergoing US-guided transperineal prostatic biopsy with Chiba and Tru-Cut needles. To evaluate the activation degree of coagulation factors in the circulation, the authors measured the concentrations of urinary fibrin degradation products in 10 patients undergoing US-guided transperineal prostatic biopsy, both before and after biopsy, every second hour, for 24 hours. Every tube of urine sample contained soya bean trypsin inhibitor and bovine thrombin to prevent any further fibrin degradation during incubation period for the possible presence of blood in urine samples. The results showed that 7/10 patients had marked increase in urinary fibrin degradation product levels (up to 800 XXXX%), with a 3-phase trend: early peak after 2-6 hours, middle peak after 6-14 hours, and late peak after 18-24 hours, which proved the activation of the coagulation cascade

  16. Diagnostic yield and complications of transthoracic computed tomography-guided biopsies

    DEFF Research Database (Denmark)

    Vagn-Hansen, Chris Aksel; Pedersen, Malene Roland Vils; Rafaelsen, Søren Rafael

    2016-01-01

    , the tissue material was found to be sufficient. In 32% of the biopsies, a complication arose, mostly pneumothorax (30%), but chest drainage was needed in only 15% of the 520 cases. Patients with more than ten cigarette pack-years had a complication risk that was twice as high at that of patients with fewer...... packyears. We found that the risk of pneumothorax increased the further the lesion was from the skin surface, the smaller the lesions were and when the patient was biopsied in a lateral position. We also found a higher risk of complications in females than in males. CONCLUSIONS: CT-guided biopsy...... is an excellent tool for analysing pulmonary lesions. The present study clearly shows that the risk of developing a pneumothorax is significantly increased among smokers and former smokers with more than ten pack-years....

  17. Optical coherence tomography for bladder cancer - ready as a surrogate for optical biopsy? - results of a prospective mono-centre study

    Directory of Open Access Journals (Sweden)

    Karl A

    2010-03-01

    Full Text Available Abstract Introduction New modalities like Optical Coherence Tomography (OCT allow non-invasive examination of the internal structure of biological tissue in vivo. The potential benefits and limitations of this new technology for the detection and evaluation of bladder cancer were examined in this study. Materials and methods Between January 2007 and January 2008, 52 patients who underwent transurethral bladder biopsy or TUR-BT for surveillance or due to initial suspicion of urothelial carcinoma of the bladder were enrolled in this study. In total, 166 lesions were suspicious for malignancy according to standard white light cystoscopy. All suspicious lesions were scanned and interpreted during perioperative cystoscopy using OCT. Cold cup biopsies and/or TUR-B was performed for all these lesions. For this study we used an OCT-device (Niris®, Imalux®, Cleveland, US, that utilizes near-infrared light guided through a flexible fibre-based applicator, which is placed into the bladder via the working channel of the cystoscope. The technology provides high spatial resolution on the order of about 10-20 μm, and a visualization of tissue to a depth of about 2 mm across a lateral span of about 2 mm in width. The device used received market clearance from the FDA and CE approval in Germany. The diagnostic and surgical procedure was videotaped and analyzed afterwards for definitive matching of scanned and biopsied lesion. The primary aim of this study was to determine the level of correlation between OCT interpretation and final histological result. Results Of 166 scanned OCT images, 102 lesions (61.4% matched to the same site where the biopsy/TUR-BT was taken according to videoanalysis. Only these video-verified lesions were used for further analysis. Of all analyzed lesions 88 were benign (inflammation, edema, hyperplasia etc. and 14 were malignant (CIS, Ta, T1, T2 as shown by final histo pathology. All 14 malignant lesions were detected correctly by

  18. Performance of combined clinical mammography and needle biopsy: a nationwide study from Denmark

    DEFF Research Database (Denmark)

    Jensen, Allan; Rank, Fritz; Dyreborg, Uffe

    2006-01-01

    Clinical mammography and needle biopsy are key tools for non-operative assessment of breast lesions. We evaluated the performance of all combined tests undertaken in Denmark in 2000. Clinical mammography and needle biopsy data were collected and linked to final cancer outcome, to determine sensit...... with a suspicious or malignant result indicated a high risk of cancer, and excisional diagnostic biopsy therefore still has an important role to play.......Clinical mammography and needle biopsy are key tools for non-operative assessment of breast lesions. We evaluated the performance of all combined tests undertaken in Denmark in 2000. Clinical mammography and needle biopsy data were collected and linked to final cancer outcome, to determine...

  19. Prevalence of mabDAS-1 positivity in biopsy specimens from the esophagogastric junction.

    Science.gov (United States)

    Rogge-Wolf, Claudia; Seldenrijk, Cornelis A; Das, Kiron M; Timmer, Robin; Breumelhof, Ronald; Smout, André J P M; Amenta, Peter S; Griffel, Louis H

    2002-12-01

    Intestinal metaplasia (IM) is a precursor for malignancies at the esophagogastric junction. A monoclonal antibody, mAbDAS-1, can probably identify cellular characteristics of IM before the appearance of goblet cells. The aim of this study was to examine the prevalence of mAbDAS-1 positivity in biopsies from the squamocolumnar junction (SCJ) and to correlate this positivity with the presence of IM and clinical findings. In 559 patients, reflux symptoms were scored, and the presence of reflux esophagitis and hiatus hernia was evaluated during endoscopy. Two biopsy specimens were obtained from the SCJ. In a subset of patients (n = 99), biopsies from the endoscopically defined cardiac region (2 cm distal to proximal margin of gastric folds) were available. Biopsy specimens were stained with hematoxylin and eosin, Alcian Blue, modified Giemsa, and mAbDAS-1. mAbDAS-1 positivity was observed in the SCJ biopsies of 201 of 486 (41.4%) patients without IM and in 64 of 73 (87.7%) patients with IM. Patients without IM but with antibody positivity showed similar histological characteristics as patients with IM at the SCJ. Biopsies of 123 of 559 patients (22%) revealed a columnar-cuboidal epithelium, which was found to be mAbDAS-1 positive in 64.2% (77 of 123). Tissue specimens from the cardiac region without IM stained positive in 14.2% (13 of 91), 12 of those also stained at the SCJ. In patients without IM, a high prevalence of mAbDAS-1 positivity was observed. Biopsies of these patients showed similar histological characteristics as patients with IM. Although not all patients exhibiting this reactivity may develop IM, mAbDAS-1 reactivity may help in the understanding of the histogenesis of IM at the SCJ.

  20. Image-guided breast biopsy: state-of-the-art

    Energy Technology Data Exchange (ETDEWEB)

    O' Flynn, E.A.M., E-mail: lizoflynn@doctors.org.u [South East London Breast Screening Programme and National Breast Screening Training Centre, Kings College Hospital NHS Foundation Trust, London SE5 9RS (United Kingdom); Wilson, A.R.M.; Michell, M.J. [South East London Breast Screening Programme and National Breast Screening Training Centre, Kings College Hospital NHS Foundation Trust, London SE5 9RS (United Kingdom)

    2010-04-15

    Percutaneous image-guided breast biopsy is widely practised to evaluate predominantly non-palpable breast lesions. There has been steady development in percutaneous biopsy techniques. Fine-needle aspiration cytology was the original method of sampling, followed in the early 1990s by large core needle biopsy. The accuracy of both has been improved by ultrasound and stereotactic guidance. Larger bore vacuum-assisted biopsy devices became available in the late 1990s and are now commonplace in most breast units. We review the different types of breast biopsy devices currently available together with various localization techniques used, focusing on their advantages, limitations and current controversial clinical management issues.

  1. Ultrasonography-guided Transthoracic Cutting Biopsy of Pulmonary Lesion: Diagnostic Benefits and Safety

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Mei Ah; Park, Mi Hyun [Dankook University Hospital, Cheonan (Korea, Republic of); Shin, Byung Seok [Chungnam National University Hospital, Daejeon (Korea, Republic of); Ohm, Joon Young [Bucheon St. Mary' s Hospital, Bucheon (Korea, Republic of)

    2012-06-15

    To assess the safety and usefulness of ultrasonography-guided transthoracic cutting biopsy for lung lesions. Eighty-eight patients (66 men, 22 women, mean age 59 years) with lung lesions underwent an ultrasonography(USG)-guided transthoracic cutting biopsy. The final diagnosis was based on the findings of surgery and clinical and radiological follow-ups. The histopathologic results and diagnostic accuracy of cutting biopsy were determined. Also, the complication rate was statistically evaluated according to the mass size, number of biopsies, and the presence or absence of pleural effusion. Biopsy specimens were successfully obtained in all patients. 79 of 88 lesions (89.8%) were established by histopathology. The final diagnosis was malignant in 58 and benign in 28. The remaining 2 patients were lost to follow-up. Diagnostic sensitivity for malignant lesions was 89.6% (52/58) and that for benign lesions was 96.4% (27/28). Procedure-related complications occurred in 9 patients (10.2%) including pneumothorax (n = 2) and hemoptysis (n = 7). And there was no significant difference according to mass size, number of biopsies, or presence of pleural effusion. USG-guided transthoracic cutting biopsy is a useful and safe method for technically-feasible lung lesions

  2. Ultrasonography-guided Transthoracic Cutting Biopsy of Pulmonary Lesion: Diagnostic Benefits and Safety

    International Nuclear Information System (INIS)

    Yang, Mei Ah; Park, Mi Hyun; Shin, Byung Seok; Ohm, Joon Young

    2012-01-01

    To assess the safety and usefulness of ultrasonography-guided transthoracic cutting biopsy for lung lesions. Eighty-eight patients (66 men, 22 women, mean age 59 years) with lung lesions underwent an ultrasonography(USG)-guided transthoracic cutting biopsy. The final diagnosis was based on the findings of surgery and clinical and radiological follow-ups. The histopathologic results and diagnostic accuracy of cutting biopsy were determined. Also, the complication rate was statistically evaluated according to the mass size, number of biopsies, and the presence or absence of pleural effusion. Biopsy specimens were successfully obtained in all patients. 79 of 88 lesions (89.8%) were established by histopathology. The final diagnosis was malignant in 58 and benign in 28. The remaining 2 patients were lost to follow-up. Diagnostic sensitivity for malignant lesions was 89.6% (52/58) and that for benign lesions was 96.4% (27/28). Procedure-related complications occurred in 9 patients (10.2%) including pneumothorax (n = 2) and hemoptysis (n = 7). And there was no significant difference according to mass size, number of biopsies, or presence of pleural effusion. USG-guided transthoracic cutting biopsy is a useful and safe method for technically-feasible lung lesions

  3. Right Ventricular Pseudoaneurysm Following Endomyocardial Biopsy.

    Science.gov (United States)

    Pita; Santos; Manteiga; Rodriguez; Beiras

    1996-03-01

    Ventricular perforation is an unusual complication after endomyocardial biopsy in heart transplanted patients. We report a case of asymptomatic right ventricular perforation and pseudoaneurysm formation, secondary to endomyocardial biopsy, diagnosed by angiography. The spontaneous obliteration of the pseudoaneurysm was observed.

  4. The effects of hypnotherapy during transrectal ultrasound-guided prostate needle biopsy for pain and anxiety.

    Science.gov (United States)

    Hızlı, Fatih; Özcan, Osman; Selvi, İsmail; Eraslan, Pınar; Köşüş, Aydın; Baş, Okan; Yıkılmaz, Taha Numan; Güven, Oğuz; Başar, Halil

    2015-11-01

    Several studies evaluating the tolerance of transrectal ultrasound (TRUS)-guided needle biopsies showed that moderate-to-severe pain was associated with the procedure. Additionally, prebiopsy anxiety or rebiopsy as a result of a prior biopsy procedure is mentioned as factors predisposing to higher pain intensity. Thus, in this study, we investigated the effects of hypnotherapy during transrectal ultrasound-guided prostate needle biopsy for pain and anxiety. Sixty-four patients presenting for TRUS-guided prostate needle biopsy were randomly assigned to receive either 10-min presurgery hypnosis session (n = 32, mean age 63.5 ± 6.1, p = 0.289) or a presurgery control session (n = 32, mean age 61.8 ± 6.8, p = 0.289). The hypnosis session involved suggestions for increased relaxation and decreased anxiety. Presurgery pain and anxiety were measured using visual analog scales (VAS), Beck Anxiety Inventory (BAI), and Hamilton Anxiety Scale (HAS), respectively. In our statistics, p < 0.05 was considered statistically significant. Postintervention, and before surgery, patients in the hypnosis group had significantly lower mean values for presurgery VAS [mean 1 (0-8); p = 0.011], BAI (6.0 vs 2.0; p < 0.001), and HAS (11.0 vs 6.0; p < 0.001). The study results indicate that a brief presurgery hypnosis intervention can be an effective means of controlling presurgical anxiety, and therefore pain, in patients awaiting diagnostic prostate cancer surgery.

  5. Ultrasonographic findings 6 months after 11-gauge vacuum-assisted large-core breast biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Docktor, B.J.L.; MacGregor, J.H.; Burrowes, P.W. [Foothills Medical Centre, Dept. of Diagnostic Imaging, Calgary, Alberta (Canada)]. E-mail: bobbie.docktor@calgaryhealthregion.ca

    2004-06-01

    To assess the ultrasonographic features of post-biopsy change 6 months after 11-gauge vacuum-assisted large-core breast biopsy of pathologically proven benign lesions. Using the literature as a reference, we hypothesized that large-core breast biopsy would result in tissue changes that may mimic malignancy and may be more apparent on ultrasonography than on mammography. Two radiologists whose subspecialty is breast imaging retrospectively reviewed the pre-biopsy and 6-month follow-up sonograms of 24 patients with pathologically proven benign lesions. The images were assessed for the number and type of ultrasonographic features. A Breast Imaging Reporting and Data System (BI-RADS) category was assigned to each lesion before biopsy and at 6-month follow-up. The composition of breast tissue surrounding the lesion was assessed as fatty, mixed fibroglandular or dense. The frequency of ultrasonographic changes at 6 months after 11-gauge vacuum-assisted large-core breast biopsy was more frequent than the rate of post-biopsy change previously reported to occur mammographically. The nature of these changes may mimic malignancy in some cases. The ultrasonographic appearance of the breast after large-core breast biopsy may mimic malignancy and is, therefore, a potential pitfall when interpreting a post-biopsy sonogram. (author)

  6. Ultrasonographic findings 6 months after 11-gauge vacuum-assisted large-core breast biopsy.

    Science.gov (United States)

    Docktor, Bobbie Jo L; MacGregor, John Henry; Burrowes, Paul W

    2004-06-01

    To assess the ultrasonographic features of post-biopsy change 6 months after 11-gauge vacuum-assisted large-core breast biopsy of pathologically proven benign lesions. Using the literature as a reference, we hypothesized that large-core breast biopsy would result in tissue changes that may mimic malignancy and may be more apparent on ultrasonography than on mammography. Two radiologists whose subspecialty is breast imaging retrospectively reviewed the pre-biopsy and 6-month follow-up sonograms of 24 patients with pathologically proven benign lesions. The images were assessed for the number and type of ultrasonographic features. A Breast Imaging Reporting and Data System (BI-RADS) category was assigned to each lesion before biopsy and at 6-month follow-up. The composition of breast tissue surrounding the lesion was assessed as fatty, mixed fibroglandular or dense. The frequency of ultrasonographic changes at 6 months after 11-gauge vacuum-assisted large-core breast biopsy was more frequent than the rate of post-biopsy change previously reported to occur mammographically. The nature of these changes may mimic malignancy in some cases. The ultrasonographic appearance of the breast after large-core breast biopsy may mimic malignancy and is, therefore, a potential pitfall when interpreting a post-biopsy sonogram.

  7. Ultrasonographic findings 6 months after 11-gauge vacuum-assisted large-core breast biopsy

    International Nuclear Information System (INIS)

    Docktor, B.J.L.; MacGregor, J.H.; Burrowes, P.W.

    2004-01-01

    To assess the ultrasonographic features of post-biopsy change 6 months after 11-gauge vacuum-assisted large-core breast biopsy of pathologically proven benign lesions. Using the literature as a reference, we hypothesized that large-core breast biopsy would result in tissue changes that may mimic malignancy and may be more apparent on ultrasonography than on mammography. Two radiologists whose subspecialty is breast imaging retrospectively reviewed the pre-biopsy and 6-month follow-up sonograms of 24 patients with pathologically proven benign lesions. The images were assessed for the number and type of ultrasonographic features. A Breast Imaging Reporting and Data System (BI-RADS) category was assigned to each lesion before biopsy and at 6-month follow-up. The composition of breast tissue surrounding the lesion was assessed as fatty, mixed fibroglandular or dense. The frequency of ultrasonographic changes at 6 months after 11-gauge vacuum-assisted large-core breast biopsy was more frequent than the rate of post-biopsy change previously reported to occur mammographically. The nature of these changes may mimic malignancy in some cases. The ultrasonographic appearance of the breast after large-core breast biopsy may mimic malignancy and is, therefore, a potential pitfall when interpreting a post-biopsy sonogram. (author)

  8. 3D non-rigid surface-based MR-TRUS registration for image-guided prostate biopsy

    Science.gov (United States)

    Sun, Yue; Qiu, Wu; Romagnoli, Cesare; Fenster, Aaron

    2014-03-01

    Two dimensional (2D) transrectal ultrasound (TRUS) guided prostate biopsy is the standard approach for definitive diagnosis of prostate cancer (PCa). However, due to the lack of image contrast of prostate tumors needed to clearly visualize early-stage PCa, prostate biopsy often results in false negatives, requiring repeat biopsies. Magnetic Resonance Imaging (MRI) has been considered to be a promising imaging modality for noninvasive identification of PCa, since it can provide a high sensitivity and specificity for the detection of early stage PCa. Our main objective is to develop and validate a registration method of 3D MR-TRUS images, allowing generation of volumetric 3D maps of targets identified in 3D MR images to be biopsied using 3D TRUS images. Our registration method first makes use of an initial rigid registration of 3D MR images to 3D TRUS images using 6 manually placed approximately corresponding landmarks in each image. Following the manual initialization, two prostate surfaces are segmented from 3D MR and TRUS images and then non-rigidly registered using a thin-plate spline (TPS) algorithm. The registration accuracy was evaluated using 4 patient images by measuring target registration error (TRE) of manually identified corresponding intrinsic fiducials (calcifications and/or cysts) in the prostates. Experimental results show that the proposed method yielded an overall mean TRE of 2.05 mm, which is favorably comparable to a clinical requirement for an error of less than 2.5 mm.

  9. Infective endocarditis with spondylodiscitis after prostate biopsy

    Directory of Open Access Journals (Sweden)

    Fernando Pivatto Júnior

    2014-04-01

    Full Text Available Transrectal ultrasonography-guided prostate needle biopsy is the ideal method to obtain prostate specimens for histological analysis and is therefore frequently used in clinical practice. In the majority of the studies, prostate biopsy is considered a safe procedure with few major complications. In the present report, we describe a case of endocarditis with spondylodiscitis, two very rare complications of prostate biopsy.

  10. Safety of liver biopsy as a day procedure in Abuth Zaria, Nigeria

    International Nuclear Information System (INIS)

    Samuel, D.O.; Okuleke, I.P.

    2012-01-01

    Chronic liver disease (CLD) is an important condition, diagnosed mainly by liver biopsy and is a leading cause of death among the working class group. It is a major burden in sub-Saharan Africa where it leads to hepatocellular carcinoma with a high mortality. This study was a retrospective one undertaken to determine the safety of performing liver biopsy procedure between January 2000 to January 2009 in terms of the frequency of indications and side effects. A total of 279 entries were found out of which 270 (96.77%) had a definitive liver biopsy histology result. The main indication for liver biopsy was chronic viral hepatitis in 150 patients (53.76%) while the commonest complication was the post-procedure pain that was seen in 16 patients (5.7%). The average duration of hospital stay after biopsy was 6.08 +- 0.52 hours. (author)

  11. Axillary sentinel node identification in breast cancer patients: degree of radioactivity present at biopsy is critical

    DEFF Research Database (Denmark)

    Nielsen, Kristina R; Oturai, Peter S; Friis, Esbern

    2011-01-01

    The radioactivity present in the patient (Act(rem) ) at sentinel node (SN) biopsy will depend on injected activity amount as well as on the time interval from tracer injection to biopsy, which both show great variations in the literature. The purpose of this study was to analyse the influence...... of varying Act(rem) levels on the outcome of axillary SN biopsy in patients with breast cancer (BC)....

  12. 21 CFR 876.1075 - Gastroenterology-urology biopsy instrument.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Gastroenterology-urology biopsy instrument. 876... SERVICES (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Diagnostic Devices § 876.1075 Gastroenterology-urology biopsy instrument. (a) Identification. A gastroenterology-urology biopsy instrument is a...

  13. Accessible or Inaccessible? Diagnostic Efficacy of CT-Guided Core Biopsies of Head and Neck Masses

    Energy Technology Data Exchange (ETDEWEB)

    Cunningham, Jane D., E-mail: janecunningham0708@gmail.com; McCusker, Mark W.; Power, Sarah; PearlyTi, Joanna; Thornton, John; Brennan, Paul; Lee, Michael J.; O’Hare, Alan; Looby, Seamus [Beaumont Hospital, Department of Radiology (Ireland)

    2015-04-15

    PurposeTissue sampling of lesions in the head and neck is challenging due to complex regional anatomy and sometimes necessitates open surgical biopsy. However, many patients are poor surgical candidates due to comorbidity. Thus, we evaluated the use of CT guidance for establishing histopathological diagnosis of head and neck masses.MethodsAll consecutive patients (n = 22) who underwent CT-guided core biopsy of head or neck masses between April 2009 and August 2012 were retrospectively reviewed using the departmental CT interventional procedures database. The indication for each biopsy performed was to establish or exclude a diagnosis of neoplasia in patients with suspicious head or neck lesions found on clinical examination or imaging studies. Patients received conscious sedation and 18 G, semiautomated core needle biopsies were performed by experienced neuroradiologists using 16-slice multidetector row CT imaging guidance (Somatom Definition Siemens Medical Solutions, Germany). Histopathology results of each biopsy were analysed.ResultsSixteen of 22 biopsies that were performed (73 %) yielded a pathological diagnosis. Anatomic locations biopsied included: masticator (n = 7), parapharyngeal (n = 3), parotid (n = 3), carotid (n = 3), perivertebral (n = 3), pharyngeal (n = 2), and retropharyngeal (n = 1) spaces. Six biopsies (27 %) were nondiagnostic due to inadequate tissue sampling, particularly small biopsy sample size and failure to biopsy the true sampling site due to extensive necrosis. No major complications were encountered.ConclusionsThe use of CT guidance to perform core biopsies of head and neck masses is an effective means of establishing histopathological diagnosis and reduces the need for diagnostic open surgical biopsy and general anaesthesia.

  14. A review of repeat prostate biopsies and the influence of technique on cancer detection: our experience.

    LENUS (Irish Health Repository)

    Quinlan, M R

    2012-02-01

    BACKGROUND: Follow-up of patients with an initial negative prostate biopsy, but surrounding whom a suspicion of prostate cancer persists, is difficult. In addition, debate exists as to the optimal technique for repeat prostate biopsy. AIMS: To assess the cancer detection rate on repeat prostate biopsy. METHODS: We reviewed patients who underwent prostate biopsy in our department in 2005 who had >or=1 previous biopsy within the preceding 5 years. Cancer detection rate on repeat biopsy and the influence of the number of biopsy cores were recorded. RESULTS: Cancer detection rate on repeat biopsy was 15.4%, with approximately 60% detected on the first repeat biopsy, but approximately 10% not confirmed until the fourth repeat biopsy. Gleason score was similar regardless of the time of diagnosis (6.1-6.5). Mean interval between first biopsy and cancer diagnosis (range 18-55 months) depended on the number of repeat procedures. There was an association between the number of biopsy cores and cancer detection. CONCLUSIONS: This study supports the practice of increasing the number of cores taken on initial and first repeat biopsy to maximise prostate cancer detection and reduce the overall number of biopsies needed.

  15. BONE MARROW BIOPSY IN EVALUATION OF HAEMATOLOGICAL DISORDERS

    Directory of Open Access Journals (Sweden)

    Sandhya Rani Sahoo

    2017-04-01

    Full Text Available BACKGROUND Bone Marrow Trephine Biopsy (BMTB and aspiration is critical for diagnosis, prognostic evaluation and monitoring therapeutic response. BMTB is of greater value in assessing cellularity, degree of fibrosis, marrow architecture and especially when aspiration is dry tap. At the same time, it provides sample for immunohistochemistry. MATERIALSAND METHODS It is a single centre observational study conducted from July 2014 to July 2016 in Department of Pathology, S.C.B. Medical College, Cuttack, which included both cell block and touch imprint along with trephine biopsy. Cases selected where lymphoma studied for pattern and extent of infiltration. Aspiration with dry tap and selected cases of myeloproliferative disorders, myelodysplastic syndrome, leukaemia (both acute and chronic, anaemia, multiple myeloma were studied. Jamshidi needle was used for biopsy. Samples obtained were formalin preserved, kept in decalcification solution (Hammersmith protocol and H and E slides prepared. Special stain-like reticulin and Masson’s trichrome were used for grading of fibrosis. Immunohistochemistry was done on selected cases of lymphoma. RESULTS Out of total 100 cases studied, 60 were of haematopoietic and lymphoid neoplasms, 12 anaemia, 20 secondary metastasis, 8 miscellaneous (1 haemophagocytic lymphohistiocytic disease, 1 storage disease, 1 granulomatous and 5 ITP. CONCLUSION The study was conducted to establish the advantage of bone marrow biopsy in inadequate and failed aspiration, but both are complementary to each other and together provide a comprehensive evaluation of the bone marrow. Bone marrow fibrosis are well accessed and increased detection of tumour cells in suspected secondary metastasis. Special stains, IHC, cytogenetic study can be done over biopsy block.

  16. Outpatient percutaneous renal biopsy in adult patients

    International Nuclear Information System (INIS)

    Al-Hweish, Abdulla K.; Abdul-Rehman, I. Saeed

    2007-01-01

    To study the safety and efficacy of performing percutanaeous renal biopsy in the outpatient department compared to the traditional inpatient policy, we studied 44 consecutive patients with proteinuria and other urinary sediment abnormalities, at King Fahd Hospital of the University, Al-Khobar, Saudi Arabia, during the period from September 2004 to August 2006. The patients were divided into two groups: group I, in whom kidney biopsy was performed and followed by 1-day hospital admission; and group II, in whom renal biopsy was performed in the outpatient department and followed by 6 hours observation period and then by regular outpatient visits. All biopsies were performed with the use of real-time ultrasound and automated biopsy needle. Patients with a history of bleeding diathesis or abnormal coagulation profile and those receiving warfarin, heparin, aspirin or nonsteroidal anti-inflammatory drugs were excluded from the study. Only minor biopsy-related complications such as gross hematuria, perinephric hematoma that resolved without the need for blood transfusion or surgical intervention occurred in three (13.6%) patients in group I and in two (9.1%) patients in group II. The complications were apparent within 6 hours in all but one patient (97.7%). Overall, hematuria was identified in 52% of patients at <-72 hours, 85% at <-4 hours and 97.7% at <- 6 hours. The 24-hour hematocrit levels were not significantly different between the study groups. One (4.5%) patient from group II had a small perinephric hematoma, which was detected by ultrasound examination at 24 hours but not at 6 hours post biopsy period; it resolved spontaneously without intervention. We conclude that in selected patients, same day discharge after 6 hours of renal biopsy may be given safety without increased risk of complications. (author)

  17. Tissue Biopsies in Diabetes Research

    DEFF Research Database (Denmark)

    Højlund, Kurt; Gaster, Michael; Beck-Nielsen, Henning

    2007-01-01

    resistance of glucose disposal and glycogen synthesis in this tissue are hallmark features of type 2 diabetes in humans (2,3). During the past two decades, we have carried out more than 1200 needle biopsies of skeletal muscle to study the cellular mechanisms underlying insulin resistance in type 2 diabetes....... Together with morphological studies, measurement of energy stores and metabolites, enzyme activity and phosphorylation, gene and protein expression in skeletal muscle biopsies have revealed a variety of cellular abnormalities in patients with type 2 diabetes and prediabetes. The possibility to establish...... and gene expression profiling on skeletal muscle biopsies have pointed to abnormalities in mitochondrial oxidative phosphorylation in type 2 diabetes. These novel insights will inevitably cause a renewed interest in studying skeletal muscle. This chapter reviews our experience to date and gives a thorough...

  18. High concordance of findings obtained from transgluteal magnetic resonance imaging - and transrectal ultrasonography-guided biopsy as compared with prostatectomy specimens.

    Science.gov (United States)

    Steurer, Stefan; Rico, Sebastian Dwertmann; Simon, Ronald; Minner, Sarah; Tsourlakis, Maria Christina; Krech, Till; Koop, Christina; Graefen, Markus; Heinzer, Hans; Adam, Meike; Huland, Hartwig; Schlomm, Thorsten; Sauter, Guido; Lumiani, Agron

    2017-09-01

    To determine the utility of our transgluteal magnetic resonance imaging (MRI)-guided prostate biopsy approach. A total of 960 biopsy series, taken within the period of 1 year, were evaluated, including 301 MRI-guided and 659 transrectal ultrasonography (TRUS)-guided biopsies. The positivity rate and proportion of high grade cancers were significantly higher in MRI-guided than in TRUS-guided biopsies. Of 301 MRI-guided biopsies, 65.4% contained cancer while 57.2% of 659 TRUS biopsies contained cancer (P = 0.016). Gleason grade 3 + 3 = 6 disease was observed in 16.8% of 197 MRI-guided and in 36.1% of 377 TRUS-guided biopsies (P guided biopsies. In all cancers, the mean cancer surface area was 64.8 ± 51.6 mm 2 in MRI-guided biopsies as compared with 23.0 ± 31.4 mm 2 in non-MRI-guided biopsies (P guided biopsy was highest in Gleason grade 3 + 3 = 6 cancers (20.9 ± 27.9 vs 5.1 ± 10.2 mm 2 ; P guided and in 170 patients with non-MRI-guided biopsies. This comparison showed a very high but almost identical concordance of TRUS- and MRI-guided biopsies with the prostatectomy specimen findings. With both approaches, undetected high-risk cancers were present in ~10% of patients with low-risk biopsy results. A significant difference was observed, however, in the proportion of patients who had clinically insignificant cancers and who underwent surgery. The proportion of patients with Gleason grade 3 + 3 = 6 carcinoma in their prostatectomy specimen was 11.2% in the post-TRUS biopsy cohort, but only 2.5% in the post-MRI biopsy cohort (P = 0.021). MRI-guided transgluteal prostate biopsy has a high detection rate for high-risk carcinomas, while the risk of detecting clinically insignificant carcinomas appears to be reduced. This may by itself lead to a reduction of unnecessary prostatectomies. Overtreatment may be further avoided by better applicability of molecular testing to MRI-guided biopsies because of the excessive amount of tissue available for analysis, especially in

  19. Proton magnetic resonance chemical shift imaging (1H CSI)-directed stereotactic biopsy

    International Nuclear Information System (INIS)

    Son, B.-C.; Kim, B.-C.; Kang, J.-K.; Choi, B.-G.; Kim, E.-N.; Baik, H.-M.; Choe, B.-Y.; Naruse, S.

    2001-01-01

    Introduction. To add metabolic information during stereotactic biopsy target selection, the authors adopted proton chemical shift imaging ( 1 H CSI)-directed stereotactic biopsy. Currently, proton single voxel spectroscopy (SVS) technique has been reported in stereotactic biopsy. We performed 1 H CSI in combination with a stereotactic headframe and selected targets according to local metabolic information, and evaluated the pathological results. Patients and Method. The 1 H CSI-directed stereotactic biopsy was performed in four patients. 1 H CSI and conventional Gd-enhancement stereotactic MRI were performed simultaneously after the fitting of a stereotactic frame. After reconstructing the metabolic maps of N-acetylaspartate (NAA)/phosphocreatine (Cr), phosphocholine (Cho)/Cr, and Lactate/Cr ratios, focal areas of increased Cho/Cr ratio and Lac/Cr ratios were selected as target sites in the stereotactic MR images. Result. 1 H CSI is possible with the stereotactic headframe in place. No difficulty was experienced performing 1 H CSI or making a diagnosis. Pathological samples taken from areas of increased Cho/Cr ratios and decreased NAA/Cr ratios provided information upon increased cellularity, mitoses and cellular atypism, and facilitated diagnosis. Pathological samples taken from areas of increased Lac/ Cr ratio snowed predominant feature of necrosis. Conclusion. 1 H CSI was feasible with the stereotactic headframe in place. The final pathological results obtained were concordant with the local metabolic information from 1 H CSI. We believe that 1 H CSI-directed stereotactic biopsy has the potential to significantly improve the accuracy of stereotactic biopsy targeting. (author)

  20. Discrepancies between biopsy-based and excision-based grading of cervical intraepithelial neoplasia: the important role of time between excision and biopsy.

    Science.gov (United States)

    Zhang, Lu; Li, Qiang; Zhao, Mingyu; Jia, Lin; Zhang, Youzhong

    2015-05-01

    We sought to evaluate the rate of cervical intraepithelial neoplasia (CIN) ≤ 1 in loop electrosurgical excision procedure (LEEP) specimens after the treatment of biopsy-proven CIN 2-3, and to identify factors that are associated with the rate of CIN ≤ 1, especially focusing on the time interval between biopsy and LEEP. The goal of this research is to reduce the overtreatment of women with CIN 2-3. This was a retrospective study performed on women undergoing LEEP for biopsy-proven CIN 2-3 in Qilu hospital in Shandong, China. Patients were separated according to LEEP pathology (CIN ≤ 1 vs. CIN 2-3), and compared using the χ2 test and Student t test. The main outcome measures were pathologic discrepancy (defined as CIN 2-3 at biopsy, but CIN ≤ 1 at excision). Of the 391 women with biopsy-proven CIN 2-3, 26.9% had LEEP specimens with CIN ≤ 1 histologies. The likelihood of a CIN ≤ 1 LEEP specimen increases for greater biopsy-LEEP intervals (odds ratio, 1.374; 95% confidence interval, 1.089-1.735; P = 0.008). Cases in younger women and biopsy-assessed CIN 2 cases were both more likely to have CIN 1 or negative LEEP specimens. The rate of spontaneous histologic regression (defined as CIN ≤ 1 at resection) was 26.9%. These low-grade lesions were more common in LEEP specimens from young women with CIN 2 at biopsy, and who underwent LEEP later after the initial biopsy.

  1. BEM-based simulation of lung respiratory deformation for CT-guided biopsy.

    Science.gov (United States)

    Chen, Dong; Chen, Weisheng; Huang, Lipeng; Feng, Xuegang; Peters, Terry; Gu, Lixu

    2017-09-01

    Accurate and real-time prediction of the lung and lung tumor deformation during respiration are important considerations when performing a peripheral biopsy procedure. However, most existing work focused on offline whole lung simulation using 4D image data, which is not applicable in real-time image-guided biopsy with limited image resources. In this paper, we propose a patient-specific biomechanical model based on the boundary element method (BEM) computed from CT images to estimate the respiration motion of local target lesion region, vessel tree and lung surface for the real-time biopsy guidance. This approach applies pre-computation of various BEM parameters to facilitate the requirement for real-time lung motion simulation. The resulting boundary condition at end inspiratory phase is obtained using a nonparametric discrete registration with convex optimization, and the simulation of the internal tissue is achieved by applying a tetrahedron-based interpolation method depend on expert-determined feature points on the vessel tree model. A reference needle is tracked to update the simulated lung motion during biopsy guidance. We evaluate the model by applying it for respiratory motion estimations of ten patients. The average symmetric surface distance (ASSD) and the mean target registration error (TRE) are employed to evaluate the proposed model. Results reveal that it is possible to predict the lung motion with ASSD of [Formula: see text] mm and a mean TRE of [Formula: see text] mm at largest over the entire respiratory cycle. In the CT-/electromagnetic-guided biopsy experiment, the whole process was assisted by our BEM model and final puncture errors in two studies were 3.1 and 2.0 mm, respectively. The experiment results reveal that both the accuracy of simulation and real-time performance meet the demands of clinical biopsy guidance.

  2. Satellite tagging and biopsy sampling of killer whales at subantarctic Marion Island: effectiveness, immediate reactions and long-term responses.

    Directory of Open Access Journals (Sweden)

    Ryan R Reisinger

    Full Text Available Remote tissue biopsy sampling and satellite tagging are becoming widely used in large marine vertebrate studies because they allow the collection of a diverse suite of otherwise difficult-to-obtain data which are critical in understanding the ecology of these species and to their conservation and management. Researchers must carefully consider their methods not only from an animal welfare perspective, but also to ensure the scientific rigour and validity of their results. We report methods for shore-based, remote biopsy sampling and satellite tagging of killer whales Orcinus orca at Subantarctic Marion Island. The performance of these methods is critically assessed using 1 the attachment duration of low-impact minimally percutaneous satellite tags; 2 the immediate behavioural reactions of animals to biopsy sampling and satellite tagging; 3 the effect of researcher experience on biopsy sampling and satellite tagging; and 4 the mid- (1 month and long- (24 month term behavioural consequences. To study mid- and long-term behavioural changes we used multievent capture-recapture models that accommodate imperfect detection and individual heterogeneity. We made 72 biopsy sampling attempts (resulting in 32 tissue samples and 37 satellite tagging attempts (deploying 19 tags. Biopsy sampling success rates were low (43%, but tagging rates were high with improved tag designs (86%. The improved tags remained attached for 26±14 days (mean ± SD. Individuals most often showed no reaction when attempts missed (66% and a slight reaction-defined as a slight flinch, slight shake, short acceleration, or immediate dive-when hit (54%. Severe immediate reactions were never observed. Hit or miss and age-sex class were important predictors of the reaction, but the method (tag or biopsy was unimportant. Multievent trap-dependence modelling revealed considerable variation in individual sighting patterns; however, there were no significant mid- or long-term changes

  3. Percutaneous image-guided needle biopsy in children - summary of our experience with 57 children

    International Nuclear Information System (INIS)

    Sklair-Levy, M.; Lebensart, P.D.; Applbaum, Y.H.; Bar-Ziv, J.; Libson, E.; Ramu, N.; Freeman, A.; Gozal, D.; Gross, E.; Sherman, Y.

    2001-01-01

    Background: Percutaneous image-guided needle biopsy in children has been slower to gain acceptance than in adults where it is regarded as the standard clinical practice in screening suspicious masses. Objectives: To report our experience with percutaneous image-guided needle biopsy in the pediatric population and assess its clinical use, efficacy and limitations. Material and methods: Sixty-nine percutaneous image-guided needle biopsies were performed in 57 children. The age of the children ranged from 4 days to 14 years (mean 5.6 years). We used 16- to-20-gauge cutting-edge needles. Sixty-two biopsies were core-needle biopsies and 7 fine-needle aspiration biopsies. Results: There were 50 malignant lesions, 10 benign lesions and 2 infectious lesions. In 55 (88.7 %) lesions the needle biopsy was diagnostic. In 7 (11.3 %) the biopsy was non-diagnostic and the diagnosis was made by surgery. Core-needle biopsy was diagnostic in 47 of 50 (94 %) of the malignant solid tumors. In 3 out of 5 children with lymphoma, an accurate diagnosis was obtained with needle aspiration. Seven children underwent a repeated core-needle biopsy, (5 for Wilms' tumor and 2 for neuroblastoma) that was diagnostic in all cases. All the biopsies were performed without complications. Conclusion: Percutaneous image-guided needle biopsy is a simple, minimally invasive, safe and accurate method for the evaluation of children with suspicious masses. These data suggest that image-guided needle biopsy is an excellent tool for diagnosing solid tumors in the pediatric population. Negative studies should be considered nondiagnostic and followed by excisional surgical biopsies when clinical suspicion of malignancy is high. (orig.)

  4. Success rates for computed tomography-guided musculoskeletal biopsies performed using a low-dose technique

    International Nuclear Information System (INIS)

    Motamedi, Kambiz; Levine, Benjamin D.; Seeger, Leanne L.; McNitt-Gray, Michael F.

    2014-01-01

    To evaluate the success rate of a low-dose (50 % mAs reduction) computed tomography (CT) biopsy technique. This protocol was adopted based on other successful reduced-CT radiation dose protocols in our department, which were implemented in conjunction with quality improvement projects. The technique included a scout view and initial localizing scan with standard dose. Additional scans obtained for further guidance or needle adjustment were acquired by reducing the tube current-time product (mAs) by 50 %. The radiology billing data were searched for CT-guided musculoskeletal procedures performed over a period of 8 months following the initial implementation of the protocol. These were reviewed for the type of procedure and compliance with the implemented protocol. The compliant CT-guided biopsy cases were then retrospectively reviewed for patient demographics, tumor pathology, and lesion size. Pathology results were compared to the ultimate diagnoses and were categorized as diagnostic, accurate, or successful. Of 92 CT-guided procedures performed during this period, two were excluded as they were not biopsies (one joint injection and one drainage), 19 were excluded due to non-compliance (operators neglected to follow the protocol), and four were excluded due to lack of available follow-up in our electronic medical records. A total of 67 compliant biopsies were performed in 63 patients (two had two biopsies, and one had three biopsies). There were 32 males and 31 females with an average age of 50 (range, 15-84 years). Of the 67 biopsies, five were non-diagnostic and inaccurate and thus unsuccessful (7 %); five were diagnostic but inaccurate and thus unsuccessful (7 %); 57 were diagnostic and accurate thus successful (85 %). These results were comparable with results published in the radiology literature. The success rate of CT-guided biopsies using a low-dose protocol is comparable to published rates for conventional dose biopsies. The implemented low-dose protocol

  5. Success rates for computed tomography-guided musculoskeletal biopsies performed using a low-dose technique

    Energy Technology Data Exchange (ETDEWEB)

    Motamedi, Kambiz; Levine, Benjamin D.; Seeger, Leanne L.; McNitt-Gray, Michael F. [UCLA Health System, Radiology, Los Angeles, CA (United States)

    2014-11-15

    To evaluate the success rate of a low-dose (50 % mAs reduction) computed tomography (CT) biopsy technique. This protocol was adopted based on other successful reduced-CT radiation dose protocols in our department, which were implemented in conjunction with quality improvement projects. The technique included a scout view and initial localizing scan with standard dose. Additional scans obtained for further guidance or needle adjustment were acquired by reducing the tube current-time product (mAs) by 50 %. The radiology billing data were searched for CT-guided musculoskeletal procedures performed over a period of 8 months following the initial implementation of the protocol. These were reviewed for the type of procedure and compliance with the implemented protocol. The compliant CT-guided biopsy cases were then retrospectively reviewed for patient demographics, tumor pathology, and lesion size. Pathology results were compared to the ultimate diagnoses and were categorized as diagnostic, accurate, or successful. Of 92 CT-guided procedures performed during this period, two were excluded as they were not biopsies (one joint injection and one drainage), 19 were excluded due to non-compliance (operators neglected to follow the protocol), and four were excluded due to lack of available follow-up in our electronic medical records. A total of 67 compliant biopsies were performed in 63 patients (two had two biopsies, and one had three biopsies). There were 32 males and 31 females with an average age of 50 (range, 15-84 years). Of the 67 biopsies, five were non-diagnostic and inaccurate and thus unsuccessful (7 %); five were diagnostic but inaccurate and thus unsuccessful (7 %); 57 were diagnostic and accurate thus successful (85 %). These results were comparable with results published in the radiology literature. The success rate of CT-guided biopsies using a low-dose protocol is comparable to published rates for conventional dose biopsies. The implemented low-dose protocol

  6. Liver Biopsy

    Science.gov (United States)

    ... called if any of the following occur: ● Persistent abdominal or chest pain ● Vomiting ● Pallor, weakness or dizziness ● Bleeding from the site of the biopsy ● Passage of tarry black stools For more information or to locate a pediatric gastroen- terologist in your area please visit our ...

  7. Evaluation of The Value of Core Needle Biopsy in The Diagnosis of a Breast Mass

    Directory of Open Access Journals (Sweden)

    Asieh Sadat Fattahi

    2016-06-01

    Full Text Available Background: Core needle biopsy (CNB with histological findings is regarded as one of the most important diagnostic measures that make preoperative assessment and planning for appropriate treatment possible. The aim of this study was to determine the sensitivity and specificity of core biopsy results in our patients with benign and malignant breast lumps, especially for borderline breast lesions, by using a classification method.Methods: In this study, 116 patients who were referred to the Surgery Clinic of Ghaem Hospital, Mashhad University of Medical Sciences, Mashhad, Iran with breast lump and underwent diagnostic procedures such as mammography and ultrasound were selected. Core needle biopsy (Tru-cut #14 or 16 was performed. After that, excisional biopsy was done. The benign, malignant and unspecified samples obtained by core needle biopsy were evaluated with the samples of the surgical and pathological findings. Then, false positive, false negative, sensitivity, specificity, and diagnostic accuracy of the core needle biopsy method were calculated. Also, the National Health Service Breast Screening Program (NHSBSP classification was employed.Results: The mean age of the participants in this study was 39±13.13 years and the mean tumor size was 2.7 cm. An average of 3.35 biopsies was taken from all patients. Most of the pathology samples taken from CNB and excisional biopsy were compatible with invasive ductal carcinoma. Of the B type classifications, B5 was the most frequent in both methods. Borderline lesions B3 and B4 had a change in their category after surgery. About 2.5% of the samples in core biopsy were inadequate. Skin bruising was the most common core biopsy complication reported. While, the most common complication of excisional biopsy was hematoma. Accuracy, sensitivity, specificity, positive and negative predictive values of the core needle biopsy procedure compared with excisional biopsy was 95.5%, 92.6%, 100%, 100%, and 91

  8. Retrospective study comparing six - and twelve-core prostate biopsy in detection of prostate cancer

    Directory of Open Access Journals (Sweden)

    Motoi Tobiume

    2008-02-01

    Full Text Available OBJECTIVE: We compared the safety and efficacy of the 12-core biopsy with those of the conventional systematic 6-core biopsy with PSA levels between 4.1 and 20.0 ng/mL. MATERIALS AND METHODS: This study included 428 patients who underwent a 6-core biopsy and 128 patients who underwent a 12-core biopsy. Biopsies were performed transrectally under ultrasound guidance. The 12-core biopsy scheme involved obtaining 6 far lateral cores. RESULTS: For patients with PSA level between 4.1 and 10.1 ng/mL, 47 of the 265 patients who underwent 6-core biopsy and 32 of the 91 patients who underwent a12-core biopsy were diagnosed with prostate cancer (p = 0.0006. Among the patients with a PSA level between 10.1 and 20.0 ng/mL, 48 of 163 patients who underwent the 6-core biopsy and 16 of 37 patients who underwent the 12-core biopsy were diagnosed with prostate cancer (p = 0.0606. Three of the 95 patients who were diagnosed with prostate cancer through the 6-core biopsy and 12 of the 48 patients who were diagnosed through the 12-core biopsy had cancer located in the anterior apex. The 12-core biopsy increased the diagnostic rate in the apex (p = 0.001. No statistically significant differences were found in incidence of complications. CONCLUSION: We concluded that the 12-core biopsy is a safe and more effective procedure for increasing the diagnostic rate of prostate cancer than the 6-core biopsy in patients with PSA level between 4.1 and 10.0 ng/mL, and the most useful anatomical area to be added was found to be cores from the anterior apex.

  9. Should a Sentinel Node Biopsy Be Performed in Patients with High-Risk Breast Cancer?

    International Nuclear Information System (INIS)

    Westover, K.D.; Westover, M.B.; Winer, E.P.; Richardson, A.L.; Iglehart, J.D.; Punglia, R.S.

    2011-01-01

    A negative sentinel lymph node (SLN) biopsy spares many breast cancer patients the complications associated with lymph node irradiation or additional surgery. However, patients at high risk for nodal involvement based on clinical characteristics may remain at unacceptably high risk of axillary disease even after a negative SLN biopsy result. A Bayesian nomogram was designed to combine the probability of axillary disease prior to nodal biopsy with customized test characteristics for an SLN biopsy and provides the probability of axillary disease despite a negative SLN biopsy. Users may individualize the sensitivity of an SLN biopsy based on factors known to modify the sensitivity of the procedure. This tool may be useful in identifying patients who should have expanded up front exploration of the axilla or comprehensive axillary irradiation

  10. The eternal enigma in prostatic biopsy access route

    Directory of Open Access Journals (Sweden)

    Andrea Fabiani

    2017-10-01

    Full Text Available Dear Editors,We read with interest the article by Di Franco and co-workers (1. The introduction of prostatic magnetic resonance and the relative fusion-biopsy have not yet allowed the expected improvements in prostate biopsy. To our knowledge, there are no works that demonstrate the superiority of fusion techniques on the remaining ultrasound guided prostate biopsies that are still the widely used in the diagnosis of prostate cancer. Furthemore, these technologies are expensive exams and they are not yet available in all centers, especially in those minors. We work at a “minor” center and we always keep in mind that the goal of  prostatic biopsy is the diagnosis and the staging of prostatic neoplasms.. However, it remains uncertain which of the two techniques, transperineal (TP or transrectal (TR, is superior in terms of detection rate during first biopsy setting. Several studies have compared the prostate cancer detection rate but TR and TP access route in prostatic gland sampling seems to be equivalent in terms of efficiency and complications, as reported by Shen PF et al. (2, despite several methodological limitations recognized in their work. The results reported by Di Franco CA et al. represent the real life experience of most urologists that perform the PB based on their own training experience and available technical devices. From an historical viewpoint, the TP route has been the first one to be used to reach the prostate, both for diagnostic and therapeutic purposes. To date, because it seems to be more invasive and difficult, the TP route is less used worldwide than the TR one (2. Theoretically, the TP approach should detect more prostate cancer than the TR way  because the cores of the TP approach are directed longitudinally to the peripheral zone and the anterior part of the prostate (4. The results reported by Di Franco et al. seems to confirm these considerations. However, our real life experience differ from the conclusions

  11. The eternal enigma in prostatic biopsy access route.

    Science.gov (United States)

    Fabiani, Andrea; Principi, Emanuele; Filosa, Alessandra; Servi, Lucilla

    2017-10-03

    Dear Editors,We read with interest the article by Di Franco and co-workers (1). The introduction of prostatic magnetic resonance and the relative fusion-biopsy have not yet allowed the expected improvements in prostate biopsy. To our knowledge, there are no works that demonstrate the superiority of fusion techniques on the remaining ultrasound guided prostate biopsies that are still the widely used in the diagnosis of prostate cancer. Furthemore, these technologies are expensive exams and they are not yet available in all centers, especially in those minors. We work at a "minor" center and we always keep in mind that the goal of  prostatic biopsy is the diagnosis and the staging of prostatic neoplasms.. However, it remains uncertain which of the two techniques, transperineal (TP) or transrectal (TR), is superior in terms of detection rate during first biopsy setting. Several studies have compared the prostate cancer detection rate but TR and TP access route in prostatic gland sampling seems to be equivalent in terms of efficiency and complications, as reported by Shen PF et al. (2), despite several methodological limitations recognized in their work. The results reported by Di Franco CA et al. represent the real life experience of most urologists that perform the PB based on their own training experience and available technical devices. From an historical viewpoint, the TP route has been the first one to be used to reach the prostate, both for diagnostic and therapeutic purposes. To date, because it seems to be more invasive and difficult, the TP route is less used worldwide than the TR one (2). Theoretically, the TP approach should detect more prostate cancer than the TR way  because the cores of the TP approach are directed longitudinally to the peripheral zone and the anterior part of the prostate (4). The results reported by Di Franco et al. seems to confirm these considerations. However, our real life experience differ from the conclusions reached in their

  12. Breast biopsy -- ultrasound

    Science.gov (United States)

    ... org/-/media/ACR/Files/Practice-Parameters/us-guidedbreast.pdf . Updated 2016. Accessed March 14, 2017. Torrente J, Brem RF. Minimally invasive image-guided breast biopsy and ablation. In: Mauro MA, Murphy KPJ, Thomson ...

  13. Colposcopy - directed biopsy

    Science.gov (United States)

    ... squamous cells - colposcopy; Pap smear - colposcopy; HPV - colposcopy; Human papilloma virus - colposcopy; Cervix - colposcopy; Colposcopy ... also called cervical dysplasia) Cervical warts (infection with human papilloma virus , or HPV) If the biopsy does not ...

  14. Results of kidney transplantation from high-terminal creatinine donors and the role of time-zero biopsy.

    Science.gov (United States)

    Lin, N C; Yang, A H; King, K L; Wu, T H; Yang, W C; Loong, C C

    2010-11-01

    Deceased-donor kidney transplantation (DDKT) from high-terminal creatinine donors is associated with lower graft survival. These kidneys may be considered for discarding, worsening the organ shortage crisis. Using time-zero biopsy for histologic evaluation of these kidneys, we identified those organs eligible for transplantation, seeking to achieve better graft utility with comparable outcomes. From April 2004 to April 2008, 55 patients underwent DDKT. A time-zero biopsy was used to examine glomerulosclerosis, interstitial fibrosis, tubular atrophy, and arteriolar narrowing. A scoring system was used to determine a discard. Twenty-five patients received DDKT from donors whose terminal creatinine levels were >2.0 mg/dL (high terminal creatinine, HTC group) and 30 from donors whose terminal creatinine levels were creatinine, LTC group). Patients who accepted kidneys from HTC donors had shorter waiting times (P = .011) but a higher incidence of delayed graft function after transplantation (P high-terminal creatinine donors can be transplanted to overcome the organ shortage while achieving reasonable graft survival. Copyright © 2010 Elsevier Inc. All rights reserved.

  15. Relationship between histopathological changes in post partum renal biopsies and renal function tests of African women with early onset pre-eclampsia.

    Science.gov (United States)

    Khedun, S M; Naicker, T; Moodley, J

    2000-05-01

    To improve the diagnostic accuracy of concurrent renal disease in hypertension of pregnancy, biopsy evaluation is essential. In addition, establishing underlying renal disease is important for prognosis on future pregnancies. We therefore designed a study to determine the diagnostic yield of postpartum renal biopsy and the nature and frequency of complications associated with this procedure. Also, to determine relationships, if any, between renal function tests and ultrastructural and histopathological findings. Fifty renal biopsies were performed in the immediate postpartum period in black African women with early onset pre-eclampsia. Each biopsy specimen was placed in a separate container and coded so that sampling was unknown to the electron microscopist. Each biopsy specimen was divided into three parts, and processed and stained for light, fluorescent and transmission electron microscopy using conventional techniques. Renal tissue biopsies were adequate for diagnostic purposes in all cases. There were no complications in any of the 50 patients studied. Ultrastructural examination confirmed the light microscopy findings. In addition the ultrastructural findings showed intramembranous deposits, foot process fusion and mesangial deposits. In 16 patients with normal renal function tests; the biopsies evaluation from these patients showed ultrastructural changes. In the remaining 34 patients with abnormal renal function tests of varying severity; biopsy evaluation from these patients showed both ultrastructural and histopathological changes. Renal biopsy procedure is safe, and ultrastructural and histological findings obtained from postpartum renal biopsies are more informative than the routine renal function tests.

  16. Validation study of villous atrophy and small intestinal inflammation in Swedish biopsy registers

    Directory of Open Access Journals (Sweden)

    Montgomery Scott M

    2009-03-01

    Full Text Available Abstract Background Small intestinal biopsy with villous atrophy (VA is the gold standard for the diagnosis of celiac disease (CD. We validated VA (Marsh 3 and small intestinal inflammation without VA (Marsh 1+2 in Swedish regional biopsy registers. Methods All pathology departments in Sweden (n = 28 were searched to identify individuals with VA or duodenal/jejunal inflammation. The validation consisted of blinded examination of biopsy samples, manual review of biopsy reports, web surveys, and patient chart reviews of 121 individuals with VA and 39 with inflammation. Results We identified 29,148 individuals with VA and 13,446 individuals with inflammation. In a blinded examination, Swedish pathologists correctly classified 90% of biopsies with VA. Manual screening of 1,534 biopsy reports (performed by co-author JFL and a research assistant found that comorbidity other than CD was rare. IBD was the most common comorbidity and occurred in 0.3% of biopsies with VA (1.6% in inflammation. Among 114 patients with VA and available data, 108 (95% had a clinical diagnosis of CD. 79% of the validated individuals with VA and 64% of those with inflammation had documented gastrointestinal symptoms prior to biopsy. 88% of the validated individuals with VA had positive CD serology before their first biopsy. 172/180 (96% of Swedish gastroenterologists and 68/68 (100% of pediatricians perform a small intestinal biopsy in at least 9 out of 10 individuals prior to diagnosis of CD. Conclusion Regional biopsy data are feasible to identify individuals with CD and small-intestinal inflammation. The specificity of CD is high in villous atrophy.

  17. Ultrasound guided core biopsy of suspicious mammographic calcifications using high frequency and power Doppler ultrasound

    International Nuclear Information System (INIS)

    Teh, W.L.; Wilson, A.R.M; Evans, A.J.; Burrell, H.; Pinder, S.E.; Ellis, I.O.

    2000-01-01

    AIM: The pre-operative diagnosis of suspicious mammographic microcalcifications usually requires stereotactic needle biopsy. The aim of this study was to evaluate if high frequency 13 MHz ultrasound (HFUS) and power Doppler (PD) can aid visualization and biopsy of microcalcifications. MATERIALS AND METHODS: Forty-four consecutive patients presenting with microcalcifications without associated mammographic or palpable masses were examined with HFUS and PD. Ultrasound-guided core biopsy (USCB) was performed where possible. Stereotactic biopsy was carried out when US-guided biopsy was unsuccessful. Surgery was performed if a diagnosis of malignancy was made on core biopsy or if the repeat core biopsy was non-diagnostic. RESULTS: Forty-one patients (93%) had ultrasound abnormalities corresponding to mammographic calcification. USCB was performed on 37 patients. In 29/37, USCB obtained a definitive result (78.4%). USCB was non-diagnostic in 4/9 benign (44.4%) and 4/28 (14.3%) malignant lesions biopsied. The complete and absolute sensitivities for malignancy using USCB were 85.7% (24/28) and 81% (23/28), respectively. USCB correctly identified invasive disease in 12/23 (52.2%) cases. There was no significant difference in the presence of abnormal flow on PD between benign and malignant lesions. However, abnormal PD vascularity was present in 43.5% of invasive cancer and was useful in directing successful biopsy in eight cases. CONCLUSION: The combination of high frequency US with PD is useful in the detection and guidance of successful needle biopsy of microcalcifications particularly where there is an invasive focus within larger areas of DCIS. Teh, W.L. (2000)

  18. Gallium-67 imaging in human heart transplantation: correlation with endomyocardial biopsy

    International Nuclear Information System (INIS)

    Meneguetti, J.C.; Camargo, E.E.; Soares, J. Jr.

    1987-01-01

    Endomyocardial biopsy seems to be the most accurate method to use for diagnosis and follow-up of acute rejection of the transplanted heart. This investigation compared a noninvasive procedure, gallium-67 imaging, with endomyocardial biopsy in the detection of acute rejection in heart transplantation. Seven male patients (aged 41 to 54 years) sequentially had 46 gallium-67 scintigrams and 46 endomyocardial biopsies between 1 week and 8 months after transplantation. Both studies were obtained in the same day, 48 hours after the administration of an intravenous injection of gallium-67 citrate. Cardiac uptake was graded as negative, mild, moderate, and marked according to an increasing count ratio with rib and sternal uptakes. Histologic findings were graded as negative, mild acute rejection, moderate acute rejection, severe acute rejection, resolving rejection, and nonspecific reaction. Negative biopsies were not found with moderate uptake, and neither moderate nor severe acute rejection were found with negative scintigrams. Imaging sensitivity was 83% with 17% false negatives and 9% false positives. Of seven studies with moderate uptake, five showed moderate acute rejection, and the patients had specific therapy with a decline in uptake, which correlated with resolving rejection. It is conceivable that in the future this technique may be used as a screening procedure for sequential endomyocardial biopsies in the follow-up of heart transplant patients

  19. A novel technique for diaphragm biopsies in human patients.

    Science.gov (United States)

    Noullet, Séverine; Romero, Norma; Menegaux, Fabrice; Chapart, Maud; Demoule, Alexandre; Morelot-Panzini, Capucine; Similowski, Thomas; Gonzalez-Bermejo, Jésus

    2015-06-15

    The diaphragm is difficult to biopsy because of its anatomic location. We describe a new laparoscopic diaphragm biopsy technique. Fifty one patients with amyotrophic lateral sclerosis gave their consent to diaphragm biopsy in the context of an implanted phrenic nerve stimulation protocol (NCT01583088). The biopsy was taken from the costal diaphragm, after opening the parietal peritoneum with scissors, and by grasping the diaphragmatic muscle over the rib with toothed laparoscopy forceps. The first four electrocoagulation biopsies were unsuitable for morphologic examination. The following 47 biopsies were therefore performed without electrocoagulation. The mean size of the biopsy fragments obtained after preparation was 3 ± 1 × 2 ± 1 × 1 ± 1 mm (maximum: 4 × 3 × 2 mm). A diaphragmatic injury occurred during the section in three cases requiring immediate suture without causing pneumothorax. A small pleural effusion was observed on the postoperative chest x-ray in one patient with a spontaneously favorable outcome. Numerous stains were able to be performed on the fragments obtained. Diaphragm biopsy can be safely performed by laparoscopy and yields tissue suitable for our future histologic evaluation. Copyright © 2015 Elsevier Inc. All rights reserved.

  20. Nonfocal renal biopsies: adequacy and factors affecting a successful outcome.

    Science.gov (United States)

    Goldstein, Mark A; Atri, Mostafa; O'Malley, Martin; Jacks, Lindsay; John, Rohan; Herzenberg, Andrew; Reich, Heather; Ghai, Sangeet

    2013-01-01

    The purpose of this study was to evaluate factors affecting the success of ultrasound-guided core biopsy of kidneys and determine the optimum number of passes. This retrospective study evaluated 484 nonfocal renal biopsies performed with 18-gauge side-notch biopsy needles. Number of biopsy passes, serum creatinine, body mass index, needle type, transplant age, kidney size, diabetic status, and operator were evaluated as predictors of the number of biopsy passes. Four hundred seventy-four biopsies (338 transplant, 136 native) were included with mean number of passes 2.87 (3.1 native vs 2.78 transplant; P = 0.002). Mean number of glomeruli yielded per pass was 6.9 (7.2 transplant vs 6.1 native; P = 0.0002) with 3 passes adequate for histological diagnosis in 84% of biopsies. Native kidney, increasing serum creatinine level, trainee biopsy operator, and use of a Temno needle were found to be independent predictors of having more than 3 biopsy passes on multivariate analysis. Age, sex, body mass index, diabetic status, and kidney size were not associated with the number of biopsy passes. The success of a nonfocal renal biopsy has many influencing variables, and in the absence of an on-site electron microscopy technologist to immediately evaluate biopsy samples, 3 passes with an 18-gauge needle would be adequate in 84% of kidneys to achieve a histological diagnosis, with 2 passes needed for transplant kidneys to meet the Banff 97 criteria.

  1. Nasal biopsies of children exposed to air pollutants.

    Science.gov (United States)

    Calderón-Garcidueñas, L; Rodriguez-Alcaraz, A; Valencia-Salazar, G; Mora-Tascareño, A; García, R; Osnaya, N; Villarreal-Calderón, A; Devlin, R B; Van Dyke, T

    2001-01-01

    Southwest Metropolitan Mexico City (SWMMC) atmosphere is a complex mixture of air pollutants, including ozone, particulate matter, and aldehydes. Children in SWMMC are exposed chronically and sequentially to numerous toxicants, and they exhibit significant nasal damage. The objective of this study was to assess p53 accumulation by immunohistochemistry in nasal biopsies of SWMMC children. We evaluated 111 biopsies from 107 children (83 exposed SWMMC children and 24 control children residents in a pollutant-compliant Caribbean island). Complete clinical histories and physical examinations, including an ear-nose-throat (ENT) exam were done. There was a significant statistical difference in the upper and lower respiratory symptomatology and ENT findings between control and exposed children (p < 0.001). Control children gave no respiratory symptomatology in the 3 months prior to the study; their biopsies exhibited normal ciliated respiratory epithelium and were p53-negative. SWMMC children complained of epistaxis, nasal obstruction. and crusting. Irregular areas of whitish-gray recessed mucosa over the inferior and middle turbinates were seen in 25% of SWMMC children, and their nasal biopsies displayed basal cell hyperplasia, decreased numbers of ciliated and goblet cells, neutrophilic epithelial infiltrates, squamous metaplasia. and mild dysplasia. Four of 21 SWMMC children with grossly abnormal mucosal changes exhibited strong transmural nuclear p53 staining in their nasal biopsies (p 0.005, odds ratio 26). In the context of lifetime exposures to toxic and potentially carcinogenic air pollutants, p53 nasal induction in children could potentially represent. a) a checkpoint response to toxic exposures, setting up a selective condition for p53 mutation, or b) a p53 mutation has already occurred as a result of such selection. Because the biological significance of p53 nuclear accumulation in the nasal biopsies of these children is not clear at this point, we strongly

  2. Breast biopsy -- stereotactic

    Science.gov (United States)

    ... org/-/media/ACR/Files/Practice-Parameters/stereo-breast.pdf . Updated 2016. Accessed March 14, 2017. Parker C, Umphrey H, Bland K. The role of stereotactic breast biopsy in the management of breast disease. In: Cameron ...

  3. Capillary Versus Aspiration Biopsy: Effect of Needle Size and Length on the Cytopathological Specimen Quality

    International Nuclear Information System (INIS)

    Hopper, Kenneth D.; Grenko, Ronald T.; Fisher, Alicia I.; TenHave, Thomas R.

    1996-01-01

    Purpose: To test the value of the nonaspiration, or capillary, biopsy technique by experimental comparison with the conventional fine-needle aspiration technique using various needle gauges and lengths. Methods: On fresh hepatic and renal tissue from five autopsies, multiple biopsy specimens were taken with 20, 22, and 23-gauge Chiba needles of 5, 10, 15, and 20-cm length, using the aspiration technique and the capillary technique. The resultant specimens were graded on the basis of a grading scheme by a cytopathologist who was blinded to the biopsy technique. Results: The capillary technique obtained less background blood or clot which could obscure diagnostic tissue, although not significantly different from the aspiration technique (p= 0.2). However, for the amount of cellular material obtained, retention of appropriate architecture, and mean score, the capillary technique performed statistically worse than aspiration biopsy (p < 0.01). In addition, with decreasing needle caliber (increasing needle gauge) and increasing length, the capillary biopsy was inferior to the aspiration biopsy. Conclusion: The capillary biopsy technique is inferior to the aspiration technique according to our study. When the capillary technique is to be applied, preference should be given to larger caliber, shorter needles

  4. Muscle biopsies off-set normal cellular signaling in surrounding musculature

    DEFF Research Database (Denmark)

    Krag, Thomas O; Hauerslev, Simon; Dahlqvist, Julia R

    2013-01-01

    muscle tissue for at least 3 weeks after the biopsy was performed and magnetic resonance imaging suggests that an effect of a biopsy may persist for at least 5 months. Cellular signaling after a biopsy resembles what is seen in severe limb-girdle muscular dystrophy type 2I with respect to protein......Studies of muscle physiology and muscular disorders often require muscle biopsies to answer questions about muscle biology. In this context, we have often wondered if muscle biopsies, especially if performed repeatedly, would affect interpretation of muscle morphology and cellular signaling. We...... hypothesized that muscle morphology and cellular signaling involved in myogenesis/regeneration and protein turnover can be changed by a previous muscle biopsy in close proximity to the area under investigation. Here we report a case where a past biopsy or biopsies affect cellular signaling of the surrounding...

  5. The clinical application of percutaneous auto-biopsy of small lung nodular under CT-Guided

    International Nuclear Information System (INIS)

    Zhou Yuanmin; Ye Genxin; Zhang Chenghui; Wang Yu; Chen Wei

    2008-01-01

    Objective: To evaluated the clinical value of technology of petcutaneous auto-biopsy of small lung nodular under CT- Guide. Methods: 44 cases of small single lung nodular were underwent biopsy with 20G auto-biopsy needle under CT guidance. All cases underwent pathological diagnosis. Results: All 44 cases were punctured successfully. 41 cases were succeeded in first puncturation. The success ratio was 93.02%. Other 3 cases needed second puncturation. 39 of 44 cases pathological diagnosis were malignant. Only 1 case could not be diagnosed. 6 patients had lightly pneumatothorax after biopsy. 10 cases had mild pneumonorrhagia after biopsy. 2 of them had haemptysis. All cases had no complication such as infection, needle track implantation. Conclusion: The technology of CT Guidance auto-biopsy of small lung nodular is safe and effective; it has extreme diagnostic ratio and less complication. (authors)

  6. Prevalence of histological features of idiopathic noncirrhotic portal hypertension in general population: a retrospective study of incidental liver biopsies.

    Science.gov (United States)

    Zuo, Chunlai; Chumbalkar, Vaibhav; Ells, Peter F; Bonville, Daniel J; Lee, Hwajeong

    2017-09-01

    Idiopathic noncirrhotic portal hypertension (INCPH) is associated with histologic changes secondary to obliterative portal venopathy without cirrhosis. We studied the prevalence of individual histological features of INCPH in liver biopsies obtained incidentally during unrelated elective procedures and in elective liver biopsies with the diagnosis of fatty liver disease. A total of 53 incidental liver biopsies obtained intraoperatively during unrelated elective procedures and an additional 28 elective biopsies with the diagnosis of fatty liver disease without portal hypertension and cirrhosis were studied. Various histologic features of INCPH were evaluated. Shunt vessel (30%), phlebosclerosis (27%), increased number of portal vessels (19%) and incomplete septa (17%) were common in these liver biopsies after confounding factors such as co-existing fatty liver disease or fibrosis were excluded. At least one feature of INCPH was noted in 90% of the biopsies. Eight (10%) biopsies showed 5-6 features of INCPH. In total, 11 (14%) of 81 patients had risk factors associated with INCPH, including hypercoagulability, autoimmune disease, exposure to drugs, and infections. No patient had portal hypertension at the end of the follow-up. The histologic features of INCPH are seen in incidental liver biopsies and fatty liver disease without portal hypertension. Ten percent of the biopsies show 5-6 features of INCPH without portal hypertension. Interpreting histologic features in the right clinical context is important for proper patient care.

  7. Live births after polar body biopsy and frozen-thawed cleavage stage embryo transfer: case report.

    Science.gov (United States)

    Guimarães, Fernando; Roque, Matheus; Valle, Marcello; Kostolias, Alessandra; Azevedo, Rodrigo A de; Martinhago, Ciro D; Sampaio, Marcos; Geber, Selmo

    2016-12-01

    Pre-implantation genetic diagnosis (PGD) or screening (PGS) technology, has emerged and developed in the past few years, benefiting couples as it allows the selection and transfer of healthy embryos during IVF treatments. These techniques can be performed in oocytes (polar-body biopsy) or embryos (blastomere or trophectoderm biopsy). In this case report, we describe the first two live births to be published in Brazil after a polar-body (PB) biopsy. In case 1, a 42-year-old was submitted to PB biopsy with PGS due to advanced maternal age and poor ovarian reserve. Five MII oocytes underwent first and second polar body biopsy and four cleavage embryos were cryopreserved. The PGS analysis resulted in two euploid embryos (next generation sequence). A frozen-thawed embryo transfer (FET) was performed after endometrial priming and a healthy baby was delivered after a cesarean section (37 weeks, female, 3390g, 47.5 cm). In case 2, a 40-year old patient with balanced translocation and poor ovarian response was submitted to PB biopsy. Two MII oocytes underwent first and second polar body biopsy and two embryos were cryopreserved in cleavage stage. The analysis resulted in one euploid embryo that was transferred after endometrial priming. A preterm healthy baby (34 weeks, female, 2100g, 40 cm) was delivered via cesarean section. In conclusion, although the blastocyst biopsy is the norm when performing PGS/PGD during IVF treatments, other alternatives (as PB biopsy) should be considered in some specific situations.

  8. Ultrasound guided percutaneous fine needle aspiration biopsy ...

    African Journals Online (AJOL)

    )-guided percutaneous fine needle aspiration biopsy (PFNAB)/US-guided percutaneous needle core biopsy (PNCB) of abdominal lesions is efficacious in diagnosis, is helpful in treatment choice, to evaluate whether various other investigations ...

  9. Where Do Transrectal Ultrasound- and Magnetic Resonance Imaging-guided Biopsies Miss Significant Prostate Cancer?

    DEFF Research Database (Denmark)

    Boesen, Lars; Nørgaard, Nis; Løgager, Vibeke

    2017-01-01

    -guided biopsy (reTRUSbx) and targeted mpMRIbx (image fusion) of any suspicious lesion. Biopsy results were compared and the locations of missed sPCa lesions were registered. Cancer significance was defined as (1) any core with a Gleason score of >6, (2) cancer core involvement of ≥50% and for re......TRUSbx on patient level, and (3) the presence of ≥3 positive cores. RESULTS: Of the 289 patients, prostate cancer was detected in 128 (44%) with 88 (30%) having sPCa. Overall, 165 separate prostate cancer lesions were detected with 100 being sPCa. Of these, mpMRIbx and reTRUSbx detected 90% (90/100) and 68% (68...... TRUSbx and mpMRIbx missed sPCa lesions in specific segments of the prostate. Missed sPCa lesions at repeat biopsy were primarily located anteriorly for TRUSbx and posterolateral midprostatic for mpMRIbx. Localization of these segments may improve biopsy techniques in men undergoing repeat biopsies....

  10. Correlation of Utrophin Levels with the Dystrophin Protein Complex and Muscle Fibre Regeneration in Duchenne and Becker Muscular Dystrophy Muscle Biopsies.

    Science.gov (United States)

    Janghra, Narinder; Morgan, Jennifer E; Sewry, Caroline A; Wilson, Francis X; Davies, Kay E; Muntoni, Francesco; Tinsley, Jonathon

    2016-01-01

    Duchenne muscular dystrophy is a severe and currently incurable progressive neuromuscular condition, caused by mutations in the DMD gene that result in the inability to produce dystrophin. Lack of dystrophin leads to loss of muscle fibres and a reduction in muscle mass and function. There is evidence from dystrophin-deficient mouse models that increasing levels of utrophin at the muscle fibre sarcolemma by genetic or pharmacological means significantly reduces the muscular dystrophy pathology. In order to determine the efficacy of utrophin modulators in clinical trials, it is necessary to accurately measure utrophin levels and other biomarkers on a fibre by fibre basis within a biopsy section. Our aim was to develop robust and reproducible staining and imaging protocols to quantify sarcolemmal utrophin levels, sarcolemmal dystrophin complex members and numbers of regenerating fibres within a biopsy section. We quantified sarcolemmal utrophin in mature and regenerating fibres and the percentage of regenerating muscle fibres, in muscle biopsies from Duchenne, the milder Becker muscular dystrophy and controls. Fluorescent immunostaining followed by image analysis was performed to quantify utrophin intensity and β-dystrogylcan and ɣ -sarcoglycan intensity at the sarcolemma. Antibodies to fetal and developmental myosins were used to identify regenerating muscle fibres allowing the accurate calculation of percentage regeneration fibres in the biopsy. Our results indicate that muscle biopsies from Becker muscular dystrophy patients have fewer numbers of regenerating fibres and reduced utrophin intensity compared to muscle biopsies from Duchenne muscular dystrophy patients. Of particular interest, we show for the first time that the percentage of regenerating muscle fibres within the muscle biopsy correlate with the clinical severity of Becker and Duchenne muscular dystrophy patients from whom the biopsy was taken. The ongoing development of these tools to quantify

  11. Correlation of Utrophin Levels with the Dystrophin Protein Complex and Muscle Fibre Regeneration in Duchenne and Becker Muscular Dystrophy Muscle Biopsies.

    Directory of Open Access Journals (Sweden)

    Narinder Janghra

    Full Text Available Duchenne muscular dystrophy is a severe and currently incurable progressive neuromuscular condition, caused by mutations in the DMD gene that result in the inability to produce dystrophin. Lack of dystrophin leads to loss of muscle fibres and a reduction in muscle mass and function. There is evidence from dystrophin-deficient mouse models that increasing levels of utrophin at the muscle fibre sarcolemma by genetic or pharmacological means significantly reduces the muscular dystrophy pathology. In order to determine the efficacy of utrophin modulators in clinical trials, it is necessary to accurately measure utrophin levels and other biomarkers on a fibre by fibre basis within a biopsy section. Our aim was to develop robust and reproducible staining and imaging protocols to quantify sarcolemmal utrophin levels, sarcolemmal dystrophin complex members and numbers of regenerating fibres within a biopsy section. We quantified sarcolemmal utrophin in mature and regenerating fibres and the percentage of regenerating muscle fibres, in muscle biopsies from Duchenne, the milder Becker muscular dystrophy and controls. Fluorescent immunostaining followed by image analysis was performed to quantify utrophin intensity and β-dystrogylcan and ɣ -sarcoglycan intensity at the sarcolemma. Antibodies to fetal and developmental myosins were used to identify regenerating muscle fibres allowing the accurate calculation of percentage regeneration fibres in the biopsy. Our results indicate that muscle biopsies from Becker muscular dystrophy patients have fewer numbers of regenerating fibres and reduced utrophin intensity compared to muscle biopsies from Duchenne muscular dystrophy patients. Of particular interest, we show for the first time that the percentage of regenerating muscle fibres within the muscle biopsy correlate with the clinical severity of Becker and Duchenne muscular dystrophy patients from whom the biopsy was taken. The ongoing development of these

  12. Migration of Gelfoam to the gallbladder after liver biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Riddle, Chris [The Hospital for Sick Children, Image Guided Therapy, Department of Diagnostic Imaging, Toronto (Canada); Dalhousie University, School of Medicine, Halifax (Canada); Ahmed, Bilal [University of Toronto School of Medicine, Toronto (Canada); Doyle, John [The Hospital for Sick Children, Department of Hematology/Oncology, Toronto (Canada); Connolly, Bairbre L. [The Hospital for Sick Children, Image Guided Therapy, Department of Diagnostic Imaging, Toronto (Canada)

    2008-07-15

    Liver biopsy is a common procedure, with an inherent risk of bleeding. There are different ways to help avoid hemorrhage, including biopsy through a transjugular venous route or embolization of the tract with liquid or solid materials. We describe an image-guided percutaneous core needle liver biopsy with tract embolization using thick Gelfoam slurry in a pediatric oncology patient. Imaging studies acquired after the biopsy indicated that the Gelfoam mixture had likely migrated to the gallbladder and common bile duct. We report this rare occurrence with its striking imaging in order to make those performing biopsies aware of this possibility. (orig.)

  13. Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid

    Science.gov (United States)

    ... Physician Resources Professions Site Index A-Z Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid An ... Aspiration Biopsy of the Thyroid? What is Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid? During ...

  14. Use of a novel percutaneous biopsy localization device: initial musculoskeletal experience

    International Nuclear Information System (INIS)

    Roberts, C.C.; Morrison, W.B.; Deely, D.M.; Zoga, A.C.; Koulouris, G.; Winalski, C.S.

    2007-01-01

    To preliminarily evaluate a new CT-biopsy guidance device, the SeeStar (Radi, Uppsala, Sweden), for use in musculoskeletal applications. The device was evaluated using an imaging phantom and in various simulated clinical biopsy situations. The phantom study was undertaken to optimize the linear metallic artifacts produced by the guidance device. The phantom and guidance device were imaged with CT after altering different imaging parameters, including field of view, filter, focal spot size, kV, mAs, slice thickness and pitch. Clinical biopsy situations were simulated for a superficial biopsy, a deep biopsy and a horizontal biopsy approach. Altering CT parameters had little effect on the subjective appearance of the linear metal artifact, which is used to plan the biopsy approach. Placement of an 18-G needle inside of the biopsy device was subjectively helpful in exaggerating the artifact. Use of this artifact could be helpful in planning biopsy approach for deep lesions or lesions near critical structures. The metal guide on the device adequately supports a standard biopsy needle, making it potentially advantageous for biopsy of superficial lesions and lesions approached from a horizontal orientation. Use of this CT-biopsy guidance device is potentially useful for musculoskeletal applications. The linear metal artifact produced by the device can help plan the biopsy approach. The device can also be useful in biopsy situations where the biopsy needle requires external support during imaging. (orig.)

  15. Reoperative sentinel lymph node biopsy after previous mastectomy.

    Science.gov (United States)

    Karam, Amer; Stempel, Michelle; Cody, Hiram S; Port, Elisa R

    2008-10-01

    Sentinel lymph node (SLN) biopsy is the standard of care for axillary staging in breast cancer, but many clinical scenarios questioning the validity of SLN biopsy remain. Here we describe our experience with reoperative-SLN (re-SLN) biopsy after previous mastectomy. Review of the SLN database from September 1996 to December 2007 yielded 20 procedures done in the setting of previous mastectomy. SLN biopsy was performed using radioisotope with or without blue dye injection superior to the mastectomy incision, in the skin flap in all patients. In 17 of 20 patients (85%), re-SLN biopsy was performed for local or regional recurrence after mastectomy. Re-SLN biopsy was successful in 13 of 20 patients (65%) after previous mastectomy. Of the 13 patients, 2 had positive re-SLN, and completion axillary dissection was performed, with 1 having additional positive nodes. In the 11 patients with negative re-SLN, 2 patients underwent completion axillary dissection demonstrating additional negative nodes. One patient with a negative re-SLN experienced chest wall recurrence combined with axillary recurrence 11 months after re-SLN biopsy. All others remained free of local or axillary recurrence. Re-SLN biopsy was unsuccessful in 7 of 20 patients (35%). In three of seven patients, axillary dissection was performed, yielding positive nodes in two of the three. The remaining four of seven patients all had previous modified radical mastectomy, so underwent no additional axillary surgery. In this small series, re-SLN was successful after previous mastectomy, and this procedure may play some role when axillary staging is warranted after mastectomy.

  16. Bulk Genotyping of Biopsies Can Create Spurious Evidence for Hetereogeneity in Mutation Content.

    Directory of Open Access Journals (Sweden)

    Rumen Kostadinov

    2016-04-01

    Full Text Available When multiple samples are taken from the neoplastic tissues of a single patient, it is natural to compare their mutation content. This is often done by bulk genotyping of whole biopsies, but the chance that a mutation will be detected in bulk genotyping depends on its local frequency in the sample. When the underlying mutation count per cell is equal, homogenous biopsies will have more high-frequency mutations, and thus more detectable mutations, than heterogeneous ones. Using simulations, we show that bulk genotyping of data simulated under a neutral model of somatic evolution generates strong spurious evidence for non-neutrality, because the pattern of tissue growth systematically generates differences in biopsy heterogeneity. Any experiment which compares mutation content across bulk-genotyped biopsies may therefore suggest mutation rate or selection intensity variation even when these forces are absent. We discuss computational and experimental approaches for resolving this problem.

  17. Bulk Genotyping of Biopsies Can Create Spurious Evidence for Hetereogeneity in Mutation Content.

    Science.gov (United States)

    Kostadinov, Rumen; Maley, Carlo C; Kuhner, Mary K

    2016-04-01

    When multiple samples are taken from the neoplastic tissues of a single patient, it is natural to compare their mutation content. This is often done by bulk genotyping of whole biopsies, but the chance that a mutation will be detected in bulk genotyping depends on its local frequency in the sample. When the underlying mutation count per cell is equal, homogenous biopsies will have more high-frequency mutations, and thus more detectable mutations, than heterogeneous ones. Using simulations, we show that bulk genotyping of data simulated under a neutral model of somatic evolution generates strong spurious evidence for non-neutrality, because the pattern of tissue growth systematically generates differences in biopsy heterogeneity. Any experiment which compares mutation content across bulk-genotyped biopsies may therefore suggest mutation rate or selection intensity variation even when these forces are absent. We discuss computational and experimental approaches for resolving this problem.

  18. Evaluation of the tumor registration error in biopsy procedures performed under real-time PET/CT guidance.

    Science.gov (United States)

    Fanchon, Louise M; Apte, Adytia; Schmidtlein, C Ross; Yorke, Ellen; Hu, Yu-Chi; Dogan, Snjezana; Hatt, Mathieu; Visvikis, Dimitris; Humm, John L; Solomon, Stephen B; Kirov, Assen S

    2017-10-01

    The purpose of this study is to quantify tumor displacement during real-time PET/CT guided biopsy and to investigate correlations between tumor displacement and false-negative results. 19 patients who underwent real-time 18 F-FDG PET-guided biopsy and were found positive for malignancy were included in this study under IRB approval. PET/CT images were acquired for all patients within minutes prior to biopsy to visualize the FDG-avid region and plan the needle insertion. The biopsy needle was inserted and a post-insertion CT scan was acquired. The two CT scans acquired before and after needle insertion were registered using a deformable image registration (DIR) algorithm. The DIR deformation vector field (DVF) was used to calculate the mean displacement between the pre-insertion and post-insertion CT scans for a region around the tip of the biopsy needle. For 12 patients one biopsy core from each was tracked during histopathological testing to investigate correlations of the mean displacement between the two CT scans and false-negative or true-positive biopsy results. For 11 patients, two PET scans were acquired; one at the beginning of the procedure, pre-needle insertion, and an additional one with the needle in place. The pre-insertion PET scan was corrected for intraprocedural motion by applying the DVF. The corrected PET was compared with the post-needle insertion PET to validate the correction method. The mean displacement of tissue around the needle between the pre-biopsy CT and the postneedle insertion CT was 5.1 mm (min = 1.1 mm, max = 10.9 mm and SD = 3.0 mm). For mean displacements larger than 7.2 mm, the biopsy cores gave false-negative results. Correcting pre-biopsy PET using the DVF improved the PET/CT registration in 8 of 11 cases. The DVF obtained from DIR of the CT scans can be used for evaluation and correction of the error in needle placement with respect to the FDG-avid area. Misregistration between the pre-biopsy PET and the CT acquired with the

  19. CT-Guided Biopsy in Suspected Spondylodiscitis--The Association of Paravertebral Inflammation with Microbial Pathogen Detection.

    Directory of Open Access Journals (Sweden)

    Daniel Spira

    Full Text Available To search for imaging characteristics distinguishing patients with successful from those with futile microbiological pathogen detection by CT-guided biopsy in suspected spondylodiscitis.34 consecutive patients with suspected spondylodiscitis underwent CT-guided biopsy for pathogen detection. MR-images were assessed for inflammatory infiltration of disks, adjacent vertebrae, epidural and paravertebral space. CT-images were reviewed for arrosion of adjacent end plates and reduced disk height. Biopsy samples were sent for microbiological examination in 34/34 patients, and for additional histological analysis in 28/34 patients.Paravertebral infiltration was present in all 10/10 patients with positive microbiology and occurred in only 12/24 patients with negative microbiology, resulting in a sensitivity of 100% and a specificity of 50% for pathogen detection. Despite its limited sensitivities, epidural infiltration and paravertebral abscesses showed considerably higher specificities of 83.3% and 90.9%, respectively. Paravertebral infiltration was more extensive in patients with positive as compared to negative microbiology (p = 0.002. Even though sensitivities for pathogen detection were also high in case of vertebral and disk infiltration, or end plate arrosion, specificities remained below 10%.Inflammatory infiltration of the paravertebral space indicated successful pathogen detection by CT-guided biopsy. Specificity was increased by the additional occurrence of epidural infiltration or paravertebral abscesses.

  20. CT-guided percutaneous transthoracic aspiration biopsy of lung lesions: factors influencing the diagnostic accuracy

    International Nuclear Information System (INIS)

    Huang Zhenguo; Zhang Xuezhe; Wang Wu

    2006-01-01

    Objective: To investigate the factors influencing the diagnostic accuracy in CT-guided percutaneous transthoracic aspiration biopsy of lung lesions. Methods: CT-guided percutaneous transthoracic biopsy was performed in 435 patients with surgical pathologic confirmation or clinical follow-up. Univariant statistical analysis and multivariant stepwise Logistic regression analysis were used to study the influence of lesion-related factors (benignancy or malignancy, size, location, depth, presence of cavity), procedure factors (laser-guidance, position of patient) and patient-related factors (sex, age, presence of emphysema); with the accuracy of the diagnosis. Results: 1)289 lesions were diagnosed as malignant ones and 146 as benign ones. The accuracy of CT-guided biopsy was 83.4%(363/435). Univariant analysis showed that the diagnostic accuracies for malignant and benign lesions were 88.9%(257/289) and 72.6%(106/146), respectively (χ 2 =18.71, P=0.00002). Laser-group was superior to non-laser group (88.4% versus 80.9%, respectively, χ 2 =4.00, P=0.0456). Mean diameters of lesions in correct diagnostic group and non-correct diagnostic group were 3.78±1.64 cm and 3.02±1.26 cm, respectively (F=13.79, P=0.0002). 2)Multivariant stepwise Logistic regression analysis showed that among the various factors influencing the final benign or malignant diagnoses (Wald χ 2 =14.01, P=0.0002) and using laser-guidance(Wald χ 2 =3.92, P=0.0477) were significantly associated with the diagnostic accuracy. Conclusions: Final correct diagnoses (benign, malignant) are closely related to the application of laser-guidance for determining the diagnostic accuracy in CT-guided transcutaneous thoracic needle aspiration biopsy. (authors)

  1. Telepathology and Optical Biopsy

    Directory of Open Access Journals (Sweden)

    Olga Ferrer-Roca

    2009-01-01

    Full Text Available The ability to obtain information about the structure of tissue without taking a sample for pathology has opened the way for new diagnostic techniques. The present paper reviews all currently available techniques capable of producing an optical biopsy, with or without morphological images. Most of these techniques are carried out by physicians who are not specialized in pathology and therefore not trained to interpret the results as a pathologist would. In these cases, the use of telepathology or distant consultation techniques is essential.

  2. Decision analysis for the cost effectiveness of Sestamibi Scintimammography in minimizing unnecessary biopsies

    International Nuclear Information System (INIS)

    Allen, M.W.; Hendi, P.; Schwimmer, J.; Gambhir, S.S.; Bassett, L.

    2000-01-01

    The purpose of this study was to assess if breast cancer screening using sestamibi scintimammography (SSMM) in conjunction with mammography (MM) is cost effective in avoiding biopsies in healthy patients. Quantitative decision tree sensitivity analysis was used to compare the conventional MM alone strategy (strategy A) with two decision strategies for screening with SSMM; SSMM after an indeterminate mammogram (strategy B) or SSMM after both a positive and an indeterminate mammogram (strategy C). Cost effectiveness was measured by calculating the expected cost per patient and the average life expectancy per patient for baseline values as well as over a range of values for all of the variables of each strategy. Based on Medicare reimbursement values, strategies B and C showed a cost savings of $9 and $20 per patient respectively as compared to strategy A. This translates into respective savings of $189 and $420 million per year assuming 21 million females undergo screening each year. Strategies B and C did however have a loss of mean life expectancy of 0.000178 and 0.000222 years respectively as compared to strategy A due to interval progression of breast cancer in a small number of women. Strategies B and C significantly lowered the number of biopsies performed on healthy patients in the screening population by 750,063 and 1,557,915 biopsies respectively as compared to strategy A. These results quantitatively verify the potential utility of using SSMM in avoiding unnecessary biopsies

  3. Current Strategies for Quantitating Fibrosis in Liver Biopsy

    Directory of Open Access Journals (Sweden)

    Yan Wang

    2015-01-01

    Full Text Available Objective: The present mini-review updated the progress in methodologies based on using liver biopsy. Data Sources: Articles for study of liver fibrosis, liver biopsy or fibrosis assessment published on high impact peer review journals from 1980 to 2014. Study Selection: Key articles were selected mainly according to their levels of relevance to this topic and citations. Results: With the recently mounting progress in chronic liver disease therapeutics, comes by a pressing need for precise, accurate, and dynamic assessment of hepatic fibrosis and cirrhosis in individual patients. Histopathological information is recognized as the most valuable data for fibrosis assessment. Conventional histology categorical systems describe the changes of fibrosis patterns in liver tissue; but the simplified ordinal digits assigned by these systems cannot reflect the fibrosis dynamics with sufficient precision and reproducibility. Morphometric assessment by computer assist digital image analysis, such as collagen proportionate area (CPA, detects change of fibrosis amount in tissue section in a continuous variable, and has shown its independent diagnostic value for assessment of advanced or late-stage of fibrosis. Due to its evident sensitivity to sampling variances, morphometric measurement is feasible to be taken as a reliable statistical parameter for the study of a large cohort. Combining state-of-art imaging technology and fundamental principle in Tissue Engineering, structure-based quantitation was recently initiated with a novel proof-of-concept tool, qFibrosis. qFibrosis showed not only the superior performance to CPA in accurately and reproducibly differentiating adjacent stages of fibrosis, but also the possibility for facilitating analysis of fibrotic regression and cirrhosis sub-staging. Conclusions: With input from multidisciplinary innovation, liver biopsy assessment as a new "gold standard" is anticipated to substantially support the accelerated

  4. Value of Renal Biopsy in Diagnosing Infantile Nephropathic Cystinosis Associated With Secondary Nephrogenic Diabetes Insipidus.

    Science.gov (United States)

    Joyce, Emily; Ho, Jacqueline; El-Gharbawy, Areeg; Salgado, Cláudia M; Ranganathan, Sarangarajan; Reyes-Múgica, Miguel

    2017-01-01

    Cystinosis is the most common cause of inherited renal Fanconi syndrome in young children, and typically presents with laboratory findings of a proximal tubulopathy and corneal crystals by one year of age. We describe here renal biopsy findings in a 20-month-old patient with an atypical presentation of distal renal tubular acidosis, diabetes insipidus, and the absence of corneal crystals. Although renal biopsy is usually not necessary to establish the diagnosis of cystinosis, when the patient presents with atypical signs and symptoms, a renal biopsy may be extremely valuable. A 20-month-old boy presented with failure to thrive, polyuria, polydipsia, and rickets. He initially showed evidence of a renal tubular acidosis, mild renal insufficiency, and nephrogenic diabetes insipidus. His initial ophthalmologic examination did not demonstrate corneal crystals. His subsequent workup revealed phosphaturia, suggesting a partial proximal tubulopathy. Concomitantly, a renal biopsy revealed prominent podocytes with an immature glomerular appearance, and electron microscopy analysis showed numerous intracellular crystals within tubular epithelial cells. Subsequent laboratory and genetic testing confirmed a diagnosis of infantile nephropathic cystinosis. This case highlights the variability in the clinical presentation of cystinosis, resulting in an uncommon clinical picture of a rare disease. Given that treatment is available to prolong renal function and minimize the extra-renal manifestations of this disorder, early diagnosis is essential. It is important to raise the index of suspicion of cystinosis by recognizing its subtle morphological changes in young patients, and that nephrogenic diabetes insipidus can be secondary to this disorder.

  5. Pleural needle biopsy

    Science.gov (United States)

    ... own. Sometimes, a chest tube is needed to drain the air and expand the lung. There is also a chance of excessive blood loss. Considerations If a closed pleural biopsy is not enough to make a diagnosis, ...

  6. A needle guidance system for biopsy and therapy using two-dimensional ultrasound

    International Nuclear Information System (INIS)

    Bluvol, Nathan; Sheikh, Allison; Kornecki, Anat; Del Rey Fernandez, David; Downey, Donal; Fenster, Aaron

    2008-01-01

    Image-guided needle biopsies are currently used to provide a definitive diagnosis of breast cancer; however, difficulties in tumor targeting exist as the ultrasound (United States) scan plane and biopsy needle must remain coplanar throughout the procedure to display the actual needle tip position. The additional time associated with aligning and maintaining this coplanar relationship results in increased patient discomfort. Biopsy procedural efficiency is further hindered since needle pathway interpretation is often difficult, especially for needle insertions at large depths that usually require multiple reinsertions. The authors developed a system that would increase the speed and accuracy of current breast biopsy procedures using readily available two-dimensional (2D) US technology. This system is composed of a passive articulated mechanical arm that attaches to a 2D US transducer. The arm is connected to a computer through custom electronics and software, which were developed as an interface for tracking the positioning of the mechanical components in real time. The arm couples to the biopsy needle and provides visual guidance for the physician performing the procedure in the form of a real-time projected needle pathway overlay on an US image of the breast. An agar test phantom, with stainless steel targets interspersed randomly throughout, was used to validate needle trajectory positioning accuracy. The biopsy needle was guided by both the software and hardware components to the targets. The phantom, with the needle inserted and device decoupled, was placed in an x-ray stereotactic mammography (SM) machine. The needle trajectory and bead target locations were determined in three dimensions from the SM images. Results indicated a mean needle trajectory accuracy error of 0.75±0.42 mm. This is adequate to sample lesions that are <2 mm in diameter. Chicken tissue test phantoms were used to compare core needle biopsy procedure times between experienced radiologists

  7. Gleason Score Correlation Between Prostate Biopsy and Radical Prostatectomy Specimens

    Directory of Open Access Journals (Sweden)

    Erdem Öztürk

    2018-04-01

    Full Text Available Objective: Prostate cancer is the most common malignancy in men and the second cause of cancer-related mortality. Prostate biopsy and the Gleason score guide treatment decisions in prostate cancer. Several studies have investigated the correlation between biopsy scores and radical prostatectomy specimen scores. We also evaluated the correlation of Gleason scores of these specimens in our patient series. Materials and Methods: We retrospectively reviewed the data of 468 men who were diagnosed with prostate cancer and underwent radical prostatectomy between 2008 and 2017. Patients’ age, prostate-specific antigen levels at diagnosis, and prostate biopsy and radical prostatectomy specimen Gleason scores were recorded. Upgrading and downgrading were defined as increase or decrease of Gleason score of radical prostate specimen compared to Gleason score of prostate biopsy. Results: A total of 442 men diagnosed with prostate cancer were included in the study. The mean age of the patients was 62.62±6.26 years (44-84 years and mean prostate specific antigen level was 9.01±6.84 ng/mL (1.09-49 ng/mL. Prostate biopsy Gleason score was 7 in 27 (6.1% men. Radical prostatectomy specimen Gleason score was 7 in 62 (14% men. Gleason correlation was highest in the 240 patients (71.6% with score <7 and was lowest in the 31 (38.75% patients with score =7. Conclusion: This study demonstrated that the discordance rate between Gleason scores of prostate biopsy and radical prostatectomy specimens was 35.7%.

  8. Comparison of plain potassium hydroxide mounts, fungal cultures and nail plate biopsies in the diagnosis of onychomycosis

    International Nuclear Information System (INIS)

    Malik, N.A.; Nasiruddin, A.

    2006-01-01

    To compare the relative sensitivity of direct microscopy, fungal culture and nail plate biopsy in the diagnosis of onychomycosis. A total of 50 patients who were suffering from different clinical variants of onychomycosis, irrespective of their age, gender, with or without simultaneous presence of systemic diseases, were subjected to laboratory investigations including direct microscopy with 20% potassium hydroxide (KOH) for fungal hyphae, fungal cultures and nail plate biopsies. These patients were later categorized into two groups based upon the results of nail plate biopsies. Of 50 patients, 15 (30%) were positive for fungal elements in direct microscopy, 8 (16%) were positive for fungal culture and 16 (32%) revealed positive results in nail plate biopsies. Amongst nail plate biopsy positive cases, 10 (63%) were positive for direct microscopy and 6 (37.5%) were positive for fungal cultures. In biopsy negative cases, positive results for direct microscopy were seen in 5 (14.7%) patients and positive fungal culture was found in 2 (5.88%) patients. (author)

  9. Cost comparison between ultrasound-guided 14-g large core breast biopsy and open surgical biopsy: An analysis for Austria

    Energy Technology Data Exchange (ETDEWEB)

    Gruber, R., E-mail: renate.gruber@meduniwien.ac.a [Medical University of Vienna, Department of Radiology, Division of Molecular and Gender Imaging, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Walter, E. [Institute of Pharmacoeconomic Research, Wolfengasse 4/7, A-1010 Vienna (Austria); Helbich, T.H. [Medical University of Vienna, Department of Radiology, Division of Molecular and Gender Imaging, Waehringer Guertel 18-20, A-1090 Vienna (Austria)

    2010-06-15

    Purpose: To examine the budget impact of ultrasound-guided 14-g large core breast biopsy (US-guided LCBB) by comparing the costs of US-guided LCBB and open surgical biopsy (OSB); to calculate the cost savings attributable to US-guided LCBB; and to assess the frequency with which US-guided LCBB obviates the need for an OSB. Materials and methods: In a retrospective study, we reviewed 399 suspicious breast lesions on which US-guided LCBB and OSB or, in cases of benign histology, clinical follow-up, were performed. Cost savings were calculated using nationally allowed flat rates (A-drg) and patient charges. Costs were measured from both, a hospital and a socioeconomic perspective. Deterministic sensitivity analyses were simulated to assess the extent of achievable cost savings. Results: Overall cost savings for US-guided LCBB over OSB were Euro 977 ( Euro 2,337/ Euro 3,314) per case from a hospital perspective, resulting in a total cost decrease of 30% for the diagnosis of suspicious breast lesions. From a socioeconomic perspective, cost savings were Euro 1,542 ( Euro 2,600/ Euro 4,142) per case, resulting in a 37% reduction in biopsy cost. US-guided LCBB obviated the need for a surgical procedure in 240 (60%) of 399 women. In all four sensitivity analyses, costs of US-guided LCBB remained lower than that of OSB. Conclusion: From an economic perspective, US-guided LCBB is highly recommended for the diagnosis of suspicious breast lesions, as this procedure reduces the cost of diagnosis substantially. In Austria, annual cost savings would be Euro 18.5 million.

  10. Cost comparison between ultrasound-guided 14-g large core breast biopsy and open surgical biopsy: An analysis for Austria

    International Nuclear Information System (INIS)

    Gruber, R.; Walter, E.; Helbich, T.H.

    2010-01-01

    Purpose: To examine the budget impact of ultrasound-guided 14-g large core breast biopsy (US-guided LCBB) by comparing the costs of US-guided LCBB and open surgical biopsy (OSB); to calculate the cost savings attributable to US-guided LCBB; and to assess the frequency with which US-guided LCBB obviates the need for an OSB. Materials and methods: In a retrospective study, we reviewed 399 suspicious breast lesions on which US-guided LCBB and OSB or, in cases of benign histology, clinical follow-up, were performed. Cost savings were calculated using nationally allowed flat rates (A-drg) and patient charges. Costs were measured from both, a hospital and a socioeconomic perspective. Deterministic sensitivity analyses were simulated to assess the extent of achievable cost savings. Results: Overall cost savings for US-guided LCBB over OSB were Euro 977 ( Euro 2,337/ Euro 3,314) per case from a hospital perspective, resulting in a total cost decrease of 30% for the diagnosis of suspicious breast lesions. From a socioeconomic perspective, cost savings were Euro 1,542 ( Euro 2,600/ Euro 4,142) per case, resulting in a 37% reduction in biopsy cost. US-guided LCBB obviated the need for a surgical procedure in 240 (60%) of 399 women. In all four sensitivity analyses, costs of US-guided LCBB remained lower than that of OSB. Conclusion: From an economic perspective, US-guided LCBB is highly recommended for the diagnosis of suspicious breast lesions, as this procedure reduces the cost of diagnosis substantially. In Austria, annual cost savings would be Euro 18.5 million.

  11. Preliminary experience with interactive guided brain biopsies using a vertically opened 0.5-T MR system

    International Nuclear Information System (INIS)

    Schneider, J.P.; Dietrich, J.; Lieberenz, S.; Schmidt, F.; Sorge, O.; Trantakis, C.; Seifert, V.; Kellermann, S.; Schober, R.; Franke, P.

    1999-01-01

    The purpose of our study was to evaluate the feasibility and accuracy of brain biopsies performed within a vertically opened MR system. We worked with the interventional 0.5-T MR ''SIGNA SP'' (General Electric Medical Systems, Milwaukee, Wis.) with an integrated tracking device ''Flashpoint Position Encoder'' (Image Guided Technologies, USA). As a holding device for this instrument we constructed a special frame. The whole system allows an exact adjustment of an optimum biopsy direction and guidance of the biopsy in a non-stereotactic, interactive mode in near real-time. As biopsy tools we used MR-compatible aspiration and specially made side-cut needles (Daum, Germany; E-Z-EM, USA). We performed a prospective diagnostic brain biopsy study in 18 patients. Guidance of the needle was carried out using gradient-echo single-slice technique. The sample was taken after controlling the exact position of the needle tip on spin-echo images. In 12 cases an exact neuropathological diagnosis was possible. In 6 cases of negative biopsy (4 aspiration biopsies) the samples were not representative. Our results demonstrate the feasibility of interactive MR-guided minimally invasive brain biopsies in an open MR system. The best results were achieved using cut needles for biopsies of contrast-enhancing lesions visible on T1-weighted gradient-echo guidance sequence. (orig.)

  12. [Transabdominal chorionic villus sampling using biopsy forceps or needle: pregnancy outcomes by technique used].

    Science.gov (United States)

    Spallina, J; Anselem, O; Haddad, B; Touboul, C; Tsatsaris, V; Le Ray, C

    2014-11-01

    To compare pregnancy outcomes after transabdominal chorionic villus sampling using biopsy forceps or needle. Retrospective bicentric study including all women who had a transabdominal chorionic villus sampling between 2005 and 2009 (172 using biopsy forceps and 160 using needle). The primary endpoint was the rate of fetal loss, after excluding medical abortion due to the result of the biopsy. The secondary endpoint was the rate of premature rupture of the membrane. All cases were reviewed to try to determine the responsibility of the biopsy. The pregnancy outcomes were not different between the two groups: 4 (4.4%) fetal losses in the biopsy forceps group and 6 (7.4%) in the needle group (P=0.52). Only one case (1.2%) of fetal loss can be attributed to the biopsy, using a needle, and none (0%) following a forceps biospy (P=0.29). The rate of premature rupture of the membrane was comparable in the two groups. The pregnancy outcomes following chorionic villus sampling using a biopsy forceps or a needle seem comparable. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  13. Value of MR-guided localization and biopsy in breast lesions; Stellenwert der MR-gestuetzten Lokalisation und Biopsie von Brustlaesionen

    Energy Technology Data Exchange (ETDEWEB)

    Obenauer, S.; Grabbe, E.; Knollmann, F. [Abt. Diagnostische Radiologie, Georg-August-Univ. Goettingen (Germany)

    2006-05-15

    Contrast-enhanced dynamic MR mammography can provide important additional diagnostic information when performed for certain indications. When suspicious lesions are identified on MR mammography and cannot be reproduced using other imaging modalities, a decision must be made as to its management, i.e. further diagnostic work-up. One possibility is the short-term follow-up of such findings, resulting in higher costs and a possible delay in the start of treatment of a malignant lesion. An alternative to a follow-up is an MR-guide intervention. MR-compatible equipment has been developed for this purpose. This includes equipment specialized for percutaneous biopsy and preoperative localization. The following is an overview of the diagnostic value of MR-guided biopsy and preoperative localization including the relevant literature. (orig.)

  14. Implementation of BIRADSTM together with an organization of percutaneous breast biopsies: experiences, reactions

    International Nuclear Information System (INIS)

    Hergan, K.; Oser, W.; Laengle, I.

    2002-01-01

    Purpose: To record the acceptance and reactions of radiologist und physicians who recommend patients for mammography after simultaneous establishment of BIRADS TM and a registration of the results of percutaneous breast biopsies. Materials and methods: To improve clarity of mammographic reports and to provide guidance concerning any necessary percutaneous breast biopsies the Breast Imaging Data And Reporting System (BIRADS TM ) has been introduced regionally together with a registration of percutaneous breast biopsies. Using a questionnaire, 25 radiologists and 230 referring physicians were asked on acceptance and reactions concerning the established system. Results: Of the 15 answering radiologists, 93% considered BIRADS TM a worthwhile effort and 87% found the biopsy guidelines to be useful. They regarded the acceptance of the referring physicians and patients as high (80%). Up to 69% of the 52 participating physicians stated a better understanding of the mammographic reports, an easier comprehension of the dignity classification of a mammographic lesion and the feeling of an improvement in their work. Preoperative assessment of histology was found to be valuable by 94% of the referring physicians. They believe that more than half of the patients benefit from the biopsy guidelines and that the majority of patients accept this approach. Conclusion: BIRADS TM is useful to standardize and improve mammographic reports. It is advantageous to link BIRADS TM with guidelines for percutaneous breast biopsies. (orig.) [de

  15. Mammotome biopsy under ultrasound control in the diagnostics and treatment of nodular breast lesions - own experience.

    Science.gov (United States)

    Kibil, Wojciech; Hodorowicz-Zaniewska, Diana; Kulig, Jan

    2012-05-01

    Mammotome biopsy is an effective, minimally invasive, novel technique used in the verification of breast lesions.The aim of the study was to assess the value of ultrasound-guided vacuum-assisted core needle biopsy (mammotome biopsy) in the diagnostics and treatment of nodular breast lesions, considering own data.Material and methods. Analysis comprised 1183 mammotome biopsies under ultrasound control performed in 1177 female patients during the period between 2000 and 2010, at the Regional Clinic for Early Diagnostics and Treatment of Breast Lesions, I Chair and Department of General Surgery, Jagiellonian University, Collegium Medicum.Results. The average patient age amounted to 41.7 years. The size of the investigated lesions ranged between 4 and 65 mm (mean - 12 mm). The histopathological examination result was as follows: fibrocystic lesions (n=285), adenofibroma (n=477), adenosis sclerosans (n=188), hyperplasia without atypy (n=58), phyllode tumor (n=2), papilloma (n=14), hamartoma (n=1), atypical hyperplasia (n=25), in situ ductal carcinoma (n=4), in situ lobular carcinoma (n=5), infiltrating ductal carcinoma (n=114), infiltrating lobular carcinoma (n=4), non-diagnostic result (n=6). The histopathological diagnosis was obtained in 99.5% of cases. Patients diagnosed with atypical hyperplasia or cancer were qualified for surgery, according to accepted standards. The presence of a hematoma was the most common complication after the biopsy, observed in 16.5% of patients.Conclusions. The obtained results confirmed the high value of ultrasound-guided biopsies in the diagnostics of nodular breast lesions. The method is safe, minimally invasive, with few complications, providing a good cosmetic effect. In case of benign lesions with a diameter of less than 15 mm the mammotome biopsy enables to completely excise the lesions, being an alternative to open surgical biopsies. The mammotome biopsy should become the method of choice considering the diagnostics of nodular

  16. Sentinel Lymph Node Biopsy Following Neoadjuvant Chemotherapy: Review of the Literature and Recommendations for Use in Patient Management

    Directory of Open Access Journals (Sweden)

    Yan Xing

    2004-10-01

    Full Text Available Breast cancer is a significant health problem worldwide and is one of the leading causes of cancer-related mortality in women. Preoperative chemotherapy has become the standard of care for patients with locally advanced disease and is being used more frequently in patients with early-stage breast cancer. Sentinel lymph node biopsy has shown great promise in the surgical management of breast cancer patients, but its use following preoperative chemotherapy is yet to be determined. Eleven studies have been published with respect to the accuracy of sentinel lymph node biopsy following neoadjuvant chemotherapy. Ten studies showed favourable results, with the ability to identify a sentinel lymph node in 84% to 98% of cases, and reported false negative rates ranging from 0% to 20%. The accuracy of sentinel lymph node biopsy following preoperative chemotherapy for breast cancer ranges from 88% to 100%, with higher rates when specific techniques and inclusion criteria are applied. The published literature supports the use of sentinel lymph node biopsy for assessment of the axilla in patients with clinically node-negative disease following preoperative chemotherapy.

  17. Omitting duodenal biopsy in children with suspected celiac disease and extra-intestinal symptoms.

    Science.gov (United States)

    Bozzola, Mauro; Meazza, Cristina; Gertosio, Chiara; Pagani, Sara; Larizza, Daniela; Calcaterra, Valeria; Luinetti, Ombretta; Farello, Giovanni; Tinelli, Carmine; Iughetti, Lorenzo

    2017-07-15

    The aim of our study is to evaluate if in children with highly positive serology and HLA-DQ2/DQ8 (triple test, TT) and only extra-intestinal symptoms, it is possible to omit performing an intestinal biopsy for celiac disease (CD) diagnosis, as suggested by the new European Society for Pediatric Gastroenterology, Hepatology and Nutrition ESPGHAN guidelines. In this retrospective study a total of 105 patients, suspected of having CD because of extra-intestinal symptoms and showing serum tissue transglutaminase antibody (anti-tTG) and anti-endomysial antibody (EMA) measurements and HLA genotyping, were considered for the final analysis (33 boys and 72 girls; age range 1.5-17.6 years). Histological findings confirmed diagnosis of CD in 97 (92.4%) patients. Forty-one patients (39%) showed anti-tTG >10 times normal values, positive EMA and positive HLA-DQ2/DQ8 (positive TT). All of them had a diagnosis of CD, therefore there were no false positive cases. Sixty-four patients were negative for the TT. In eight cases, CD was ruled out and these were considered true negative cases. In the remaining 56 negative TT patients, intestinal biopsy confirmed CD diagnosis and they were considered false negatives. Based on these results, specificity for the TT was 100% and sensitivity was 42.3%. On the basis of the present study, diagnosis of CD can be reliably performed without a duodenal biopsy in children with only extra-intestinal symptoms.

  18. Unmasking of complements using proteinase-K in formalin fixed paraffin embedded renal biopsies

    Directory of Open Access Journals (Sweden)

    R Nada

    2016-01-01

    Full Text Available Renal biopsy interpretation requires histopathology, direct immunofluorescence (DIF and electron microscopy. Formalin-fixed, paraffin-embedded tissue (FFPE sent for light microscopy can be used for DIF after antigen retrieval. However, complement staining has not been satisfactory. We standardized DIF using proteinase-K for antigen retrieval in FFPE renal biopsies. A pilot study was conducted on known cases of membranous glomerulonephritis (MGN, membranoproliferative type-1 (MPGN-1, immunoglobulin A nephropathy (IgAN, and anti-glomerular basement disease (anti-GBM. Immunofluorescence panel included fluorescein isothiocyanate (FITC conjugated IgG, IgA, IgM, complements (C3 and C1q, light chains (kappa, lambda and fibrinogen antibodies. After standardization of the technique, 75 renal biopsies and 43 autopsies cases were stained. Out of 43 autopsy cases, immune-complex mediated glomerulonephritis (GN was confirmed in 18 cases (Lupus nephritis-11, IgAN-6, MGN-1, complement-mediated dense deposit disease (DDD-1 and monoclonal diseases in 4 cases (amyloidosis-3, cast nephropathy-1. Immune-mediated injury was excluded in 17 cases (focal segmental glomerulosclerosis -3, crescentic GN-6 [pauci-immune-3, anti-GBM-3], thrombotic microangiopathy-5, atherosclerosis-3. Renal biopsies (n-75 where inadequate or no frozen sample was available; this technique classified 52 mesangiocapillary pattern as MPGN type-1-46, DDD-2 and (C3GN-4. Others were diagnosed as IgAN-3, lupus nephritis-2, MGN-4, diffuse proliferative glomerulonephritis (DPGN-1, Non-IC crescentic GN-1, monoclonal diseases-3. In nine cases, DIF on FFPE tissue could not help in making diagnosis. Proteinase-K enzymatic digestion of FFPE renal biopsies can unmask complements (both C3 and C1q in immune-complexes mediated and complement-mediated diseases. This method showed good results on autopsy tissues archived for as long as 15 years.

  19. Medially Directed TRUS Biopsy of the Prostate: Clinical Utility and Optimal Protocol

    International Nuclear Information System (INIS)

    Park, Byung Kwan; Kim, Seung Hyup

    2012-01-01

    The objective of this study is to determine whether medially directed transrectal ultrasound (TRUS)-guided biopsy is necessary for detection of prostate cancer and for establishment of an optimal biopsy regimen that is equivalent to a systematic 12 core biopsy. A total of 302 patients underwent a TRUS-guided systematic 12 core biopsy consisting of both medial sextant biopsy obtained between the parasagittal line and midline and lateral sextant biopsy obtained between the parasagittal line and lateral border. We obtained cancer detection rates of various biopsy regimens that were produced from a systematic 12 core biopsy. Using a systematic 12 core biopsy, cancer was detected in 116 (38.4%) of 302 patients. No significant difference was observed between cancer detection rates of medial sextant biopsy and lateral sextant biopsy (33.8% versus 31.5%, p >.05). Biopsy regimens that were equivalent to the systematic 12 core regarding cancer detection rate included medially directed cores that were obtained from both medial portions of the apex. Both medially directed biopsy and laterally directed biopsy are necessary for detection of prostate cancer and for establishment of an optimal biopsy regimen.

  20. Testicular biopsy in prepubertal boys

    DEFF Research Database (Denmark)

    Faure, Alice; Bouty, Aurore; O'Brien, Mike

    2016-01-01

    No consensus exists regarding the precise role of testicular biopsy in prepubertal boys, although it is considered useful for assessing the potential consequences of undescended testes on fertility. Current scientific knowledge indicates that surgeons should broaden indications for this procedure...... for the preservation of fertility after gonadotoxic chemotherapy - even for prepubertal boys - are emerging. Cryopreservation of testicular tissue samples for the preservation of fertility - although still an experimental method at present - is appealing in this context. In our opinion, testicular biopsy...

  1. In-Bore MR-Guided Biopsy Systems and Utility of PI-RADS.

    Science.gov (United States)

    Fütterer, Jurgen J; Moche, Michael; Busse, Harald; Yakar, Derya

    2016-06-01

    A diagnostic dilemma exists in cases wherein a patient with clinical suspicion for prostate cancer has a negative transrectal ultrasound-guided biopsy session. Although transrectal ultrasound-guided biopsy is the standard of care, a paradigm shift is being observed. In biopsy-naive patients and patients with at least 1 negative biopsy session, multiparametric magnetic resonance imaging (MRI) is being utilized for tumor detection and subsequent targeting. Several commercial devices are now available for targeted prostate biopsy ranging from transrectal ultrasound-MR fusion biopsy to in bore MR-guided biopsy. In this review, we will give an update on the current status of in-bore MRI-guided biopsy systems and discuss value of prostate imaging-reporting and data system (PIRADS).

  2. Comparison between preoperative biopsy and post-excision ...

    African Journals Online (AJOL)

    peripheral nerve sheath tumour (6%).[6] Soft-tissue sarcomas most frequently affect the extremities and include MFH (40%), lipo- sarcoma (25%), synovial sarcoma and fibrosarcoma.[7]. Appropriate management is reliant on an accurate preoperative histology result. Excision biopsy is recommended for tumours. <3 cm in ...

  3. Axillary lymph node core biopsy for breast cancer metastases — How many needle passes are enough?

    International Nuclear Information System (INIS)

    Macaskill, E.J.; Purdie, C.A.; Jordan, L.B.; Mclean, D.; Whelehan, P.; Brown, D.C.; Evans, A.

    2012-01-01

    Aim: To determine the diagnostic yield of each of three core passes when sampling abnormal lymph nodes in patients presenting with breast cancer. Materials and methods: All patients suspected of having breast cancer had axillary ultrasound as part of initial assessment. Radiologically abnormal nodes (cortical thickness >2.3 mm or round shape) were biopsied with three passes of a 22 mm throw 14 G core biopsy needle and sent for histopathology in separate numbered pots. Data were collected prospectively, and analysis performed on the data of 55 consecutive patients who had positive nodes on at least one core biopsy needle pass. Results: Of 55 patients with a positive node on core biopsy, tumour was noted in all three cores taken in 39 (70.9%). Lymph node metastasis was detected in 45 (81.8%) first core biopsies. With the first two cores taken, positive results were detected in 53 of 55 cases (96.4%). In both cases where tumour was only found on a third core biopsy pass, no lymph node tissue was present in the first two biopsy passes. Conclusion: Two well-directed 14 G core biopsy samples from an abnormal axillary node are adequate for diagnosis of breast cancer metastasis.

  4. Effectiveness of Sedoanalgesia in Percutaneous Liver Biopsy Premedication

    Science.gov (United States)

    Sezgin, Orhan; Ates, Fehmi; Altintas, Engin; Saritas, Bunyamin

    2017-01-01

    Aim: Percutaneous needle liver biopsy (PLB) is frequently associated with pain and anxiety. This may discourage the patients for biopsy, and rebiopsies, if needed. We planned a study to investigate the efficacy of additional analgesia or sedation for PLB. Materials and methods: The study has been designed as a single-center, prospective study. The PLB was planned for 18- to 65-year-old consecutive patients who were included in the study. The patients were divided into three premedication groups as control, Meperidine, and Midazolam. Hospital Anxiety and Depression Scale (HADS) was used to measure each subject’s anxiety level. Fifteen minutes before the biopsy, 1 mL 0.9% NaCl subcutaneously (sc), 1 mg/kg (max 100 mg) Meperidine sc, or 0.1 mg/kg (max 5 mg) Midazolam intravenously was administered to patients respectively. Then PLB was done with 16 G Menghini needle. The day after, the patients were asked about feelings regarding biopsy. Results: Groups were similar by gender and age. The HADS scores prior to PLB and on visual analog scale (VAS, 1-10 points) score during PLB were similar. In the three groups, 7, 12, and 7 patients, respectively, experienced no pain. Other patients explained pain as mild or moderate or severe. The number of patients who agreed for possible rebiopsy was higher in Meperidine and Midazolam groups than in the control group. Conclusion: Premedication with Meperidine or Midazolam in PLB would improve patients’ tolerance, comfort, and attitude against a possible repeat PLB. How to cite this article: Sezgin O, Yaras S, Ates F, Altintas E, Saritas B. Effectiveness of Sedoanalgesia in Percutaneous Liver Biopsy Premedication. Euroasian J Hepato-Gastroenterol 2017;7(2):146-149. PMID:29201797

  5. Assessment and clinical factors associated with pain in patients undergoing transrectal prostate biopsy.

    Science.gov (United States)

    Gómez-Gómez, E; Ramírez, M; Gómez-Ferrer, A; Rubio-Briones, J; Iborra, I; J Carrasco-Valiente; Campos, J P; Ruiz-García, J; Requena-Tapia, M J; Solsona, E

    2015-09-01

    To quantify the degree of pain experienced by patients who undergo ultrasound-guided transrectal prostate biopsy in standard clinical practice and assess the clinical factors associated with increased pain. Analysis of a multicenter series of patients with prostate biopsy according to standard clinical practice. The biopsy was performed transrectally with a protocol of local anesthesia on the posterolateral nerve bundle. The pain was assessed at 20minutes into the procedure using the visual analog scale (0-10). The degree of pain was analyzed, and the association was studied using a univariate/multivariate analysis of selected clinical variables and the degree of pain. A total of 1188 patients with a median age of 64 years were analyzed. Thirty percent of the biopsies were diagnosed with a tumor. The median pain score was 2, with 65% of the patients reporting a pain score ≤2. The multivariate analysis showed that the prostate volume (RR, 1.34; 95% CI 1.01-1.77; P=.04), having a previous biopsy (RR, 2.25; 95% CI 1.44-3.52; P<.01), age (RR, .63; 95% CI .47-.85; P<.01) and feel palpation (RR, 1.95; 95% CI 1.28-2.96; P<.01) were factors independently associated with greater pain during the procedure. Transrectal biopsy with local anesthesia is a relatively painless technique. Factors such as age, a previous biopsy, pain on being touched and prostate volume were associated with the presence of greater pain during the procedure. Copyright © 2014 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  6. Morphologic Features Suggestive of Endometriosis in Nondiagnostic Peritoneal Biopsies.

    Science.gov (United States)

    Harrison, Beth T; Mittal, Khush

    2015-11-01

    Endometriosis is a common disorder that causes significant morbidity from dysmenorrhea, pelvic pain, and subfertility. Establishment of a definitive diagnosis has important therapeutic implications; however, only approximately 50% of biopsies of laparoscopically suspicious areas provide a diagnosis of endometriosis. Histologic criteria for diagnosis require the presence of endometrial glands or endometrial-type stroma. We hypothesize that other frequently present, but nondiagnostic, histologic features of endometriosis suggest its presence in patients with nondiagnostic peritoneal biopsies. We performed a retrospective clinicopathologic study of morphologic and immunohistochemical features that may improve the histologic diagnosis of endometriosis on laparoscopic peritoneal biopsies. We compared diagnostic (n=88) and nondiagnostic (n=54) peritoneal biopsies from pathologically confirmed endometriosis cases with negative peritoneal biopsies (n=84) from early-stage gynecologic cancer cases. Statistical analysis utilized the Fisher exact test. Multiple morphologic features were significantly increased in nondiagnostic biopsies from patients with endometriosis in comparison with those from negative controls, including foamy macrophages (P=0.0001) and submesothelial stromal clusters (SSCs) (P=0.0008). SSCs ranged from subtle aggregates of spindle cells to nodules of whorled spindle cells with small vessels and extravasated red blood cells resembling stromal endometriosis. Immunohistochemical studies confirmed that ER and CD10-positive SSCs were present in a greater proportion of both nondiagnostic and diagnostic peritoneal biopsies and at a greater number of lesions per biopsy. The overall histologic detection rate of peritoneal biopsies for endometriosis was 62.0%, and inclusion of SSCs with or without foamy macrophages in the diagnostic criteria appreciably increased this rate to between 72.5% and 76.8%. We describe SSCs, which appear to be an early or less developed

  7. Sensitivity of Computed Tomography‑guided Transthoracic Biopsies ...

    African Journals Online (AJOL)

    2018-03-05

    Mar 5, 2018 ... Introduction: The indications for open biopsies for intrathoracic lesions have become almost negligible. This development was made possible by less invasive maneuvers such as computed tomography‑guided (CT‑guided) biopsy, thoracoscopy or video‑assisted thoracoscopy, and bronchoscopy.

  8. Sensitivity of Computed Tomography‑guided Transthoracic Biopsies ...

    African Journals Online (AJOL)

    Introduction: The indications for open biopsies for intrathoracic lesions have become almost negligible. This development was made possible by less invasive maneuvers such as computed tomography‑guided (CT‑guided) biopsy, thoracoscopy or video‑assisted thoracoscopy, and bronchoscopy. CT‑guided percutaneous ...

  9. Nursing care for patients receiving perccutaneous biopsy of the pancreas under CT-guidance

    International Nuclear Information System (INIS)

    Li Yongli; Wang Zhenfang

    2010-01-01

    Objective: To discuss the application of nursing care in CT-guided percutaneous biopsy of the pancreas. Methods: The perioperative nursing measures were carried out in 21 patients receiving percutaneous biopsy of the pancreas under CT-guidance. Active, effective and comprehensive nursing procedures were adopted to closely cooperate with the whole process of percutaneous biopsy as far as possible. Results: All the patients could actively cooperate with the physician during the whole process of percutaneous biopsy and the surgery was successfully completed in all patients. The technical success rate with only single puncture was 100%. No obvious complications occurred after the procedure. Conclusion: In order to ensure that the patient will be able to cooperate with the CT-guided percutaneous biopsy of the pancreas, that the operation time can be shortened and that the postoperative complications can be avoided, perioperative nursing care is indispensable. (authors)

  10. Malignancy rate of biopsied suspicious bone lesions identified on FDG PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Adams, Hugo J.A.; Kwee, Thomas C. [University Medical Center Utrecht, Department of Radiology and Nuclear Medicine, Utrecht (Netherlands); Klerk, John M.H. de [Meander Medical Center, Department of Nuclear Medicine, Amersfoort (Netherlands); Heggelman, Ben G.F. [Meander Medical Center, Department of Radiology, Amersfoort (Netherlands); Dubois, Stefan V. [Meander Medical Center, Department of Pathology, Amersfoort (Netherlands)

    2016-07-15

    To determine the malignancy rate of bone lesions identified on FDG PET/CT in patients who have undergone CT-guided biopsy because of the suspicion of malignancy. This single-centre retrospective study spanned eight consecutive years and included all patients who underwent both FDG PET/CT and CT-guided bone biopsy because of the suspicion of malignancy. The positive predictive value (PPV) for malignancy was calculated, and different patient and imaging characteristics were compared between malignant and benign bone lesions. Of 102 included patients with bone lesions that all showed FDG uptake exceeding mediastinal uptake, bone biopsy showed a malignant lesion in 91 patients, yielding a PPV for malignancy of 89.2 % (95 % CI 81.7 - 93.9 %). In the 94 patients with bone lesions that showed FDG uptake exceeding liver uptake, bone biopsy showed a malignant lesion in 83 patients, yielding a PPV for malignancy of 88.3 % (95 % CI 80.1 - 93.5 %). Higher age, bone marrow replacement of the lesion seen on CT, expansion of the lesion seen on CT, and presence of multifocal lesions on FDG PET/CT were significantly more frequent in patients with malignant lesions than in those with benign bone lesions (P = 0.044, P = 0.009, P = 0.015, and P = 0.019, respectively). Furthermore, there was a trend towards a higher incidence of cortical destruction (P = 0.056) and surrounding soft tissue mass (P = 0.063) in patients with malignant bone lesions. The PPV for malignancy of suspicious bone lesions identified on FDG PET/CT is not sufficiently high to justify changes in patient management without histopathological confirmation. Nevertheless, ancillary patient and imaging characteristics may increase the likelihood of a malignant bone lesion. (orig.)

  11. MRI-guided trephine biopsy and fine-needle aspiration in the diagnosis of bone lesions in low-field (0.23 T) MRI system using optical instrument tracking

    International Nuclear Information System (INIS)

    Blanco Sequeiros, Roberto; Klemola, Rauli; Ojala, Risto; Jyrkinen, Lasse; Tervonen, Osmo; Lappi-Blanco, Elisa; Soini, Ylermi

    2002-01-01

    The purpose of this study was to evaluate the feasibility of MRI-guided bone biopsy with optical instrument tracking and evaluate advantage of combined fine-needle aspiration (FNA) with trephine biopsy. Twenty trephine bone biopsies and 13 FNAs were performed under MRI and CT guidance in 14 patients. Informed consent was obtained from all patients. The evaluation of diagnostic accuracy was achieved by comparing the histopathological and cytological diagnosis with current or final diagnosis made during 6-month clinical follow-up. A 0.23-T open MRI scanner with interventional tools (Outlook Proview, Marconi Medical Systems, Cleveland, Ohio) was used. A surface coil was used. For trephine biopsy MRI-compatible bone biopsy set (Daum medical, Schwerin, Germany) was used. The FNA was performed with MRI compatible 20-G needle (Cook, Bloomington, Ind.). The diagnostic accuracy of MRI-guided trephine biopsy was 95%. The FNA sample diagnosis concurred with the histological in 54%. Our results show that MRI guidance in bone biopsies is accurate and safe. It is comparable to CT-guided or open biopsy. The role of combined FNA with bone biopsies remains controversial. (orig.)

  12. The clinical relevance of plasma CD147/basigin in biopsy-proven kidney diseases.

    Science.gov (United States)

    Mori, Yoshiko; Masuda, Tomohiro; Kosugi, Tomoki; Yoshioka, Tomoki; Hori, Mayuko; Nagaya, Hiroshi; Maeda, Kayaho; Sato, Yuka; Kojima, Hiroshi; Kato, Noritoshi; Ishimoto, Takuji; Katsuno, Takayuki; Yuzawa, Yukio; Kadomatsu, Kenji; Maruyama, Shoichi

    2017-12-12

    Precise understanding of kidney disease activity is needed to design therapeutic strategies. CD147/basigin is involved in the pathogenesis of acute kidney injury and renal fibrosis through inflammatory cell infiltration. The present study examined the clinical relevance of CD147 in biopsy-proven kidney diseases that lead to the progression of chronic kidney disease. Kidney biopsy specimens and plasma and urine samples were obtained from patients with kidney diseases, including IgA nephropathy (IgAN), Henoch-Schönlein purpura nephritis (HSPN), diabetic kidney disease (DKD), focal segmental glomerulosclerosis (FSGS), and membranous nephropathy (MN), who underwent renal biopsy between 2011 and 2014. Plasma and urinary CD147 levels were measured and evaluated for their ability to reflect histological features. Disease activity of IgAN tissues was evaluated according to the Oxford classification and the Japanese histological grading system. In biopsy tissues, CD147 induction was detected in injured lesions representing renal inflammation. Plasma CD147 values correlated with eGFR in patients with inflammation-related kidney diseases such as IgAN, HSPN, and DKD. Particularly in IgAN patients, plasma CD147 levels were correlated with injured regions comprising more than 50% of glomeruli or with tubular atrophy/interstitial injury in biopsy tissues. Proteinuria showed a closer correlation with urinary values of CD147 and L-FABP. Of note, plasma and urinary CD147 levels showed a strong correlation with eGFR or proteinuria, respectively, only in DKD patients. Evaluation of plasma and urinary CD147 levels might provide key insights for the understanding of the activity of various kidney diseases.

  13. Trained nurses can obtain satisfactory bone marrow aspirates and trephine biopsies.

    Science.gov (United States)

    Lawson, S; Aston, S; Baker, L; Fegan, C D; Milligan, D W

    1999-01-01

    AIMS: To assess the feasibility of training nurse practitioners to perform bone marrow aspiration and trephine biopsy, and to compare the quality of these samples with those obtained by medical staff. METHODS: A retrospective audit was undertaken of nurse practitioner and medical staff performance in bone marrow procedures in a busy haematology day unit. RESULTS: Nurse practitioners fared favourably in comparison with medical staff in performing bone marrow trephine biopsies, with mean biopsy lengths of 11 mm and 10.7 mm respectively. However, only 78% of the smears obtained by the nurses were judged technically satisfactory, compared with 91% prepared by doctors. This discrepancy was thought to be due largely to the quality of slide spreading. CONCLUSIONS: With motivated staff and a structured educational and training programme it is possible for nurse practitioners to perform the techniques of bone marrow aspiration and biopsy, and obtain specimens of satisfactory quality, thus improving efficiency of the haematology day unit and increasing quality of patient care. Images PMID:10396248

  14. Oral biopsy: Oral pathologist′s perspective

    Directory of Open Access Journals (Sweden)

    K L Kumaraswamy

    2012-01-01

    Full Text Available Many oral lesions may need to be diagnosed by removing a sample of tissue from the oral cavity. Biopsy is widely used in the medical field, but the practice is not quite widespread in dental practice. As oral pathologists, we have found many artifacts in the tissue specimen because of poor biopsy technique or handling, which has led to diagnostic pitfalls and misery to both the patient and the clinician. This article aims at alerting the clinicians about the clinical faults arising preoperatively, intraoperatively and postoperatively while dealing with oral biopsy that may affect the histological assessment of the tissue and, therefore, the diagnosis. It also reviews the different techniques, precautions and special considerations necessary for specific lesions.

  15. Microarray analysis in clinical oncology: pre-clinical optimization using needle core biopsies from xenograft tumors

    International Nuclear Information System (INIS)

    Goley, Elizabeth M; Anderson, Soni J; Ménard, Cynthia; Chuang, Eric; Lü, Xing; Tofilon, Philip J; Camphausen, Kevin

    2004-01-01

    DNA microarray profiling performed on clinical tissue specimens can potentially provide significant information regarding human cancer biology. Biopsy cores, the typical source of human tumor tissue, however, generally provide very small amounts of RNA (0.3–15 μg). RNA amplification is a common method used to increase the amount of material available for hybridization experiments. Using human xenograft tissue, we sought to address the following three questions: 1) is amplified RNA representative of the original RNA profile? 2) what is the minimum amount of total RNA required to perform a representative amplification? 3) are the direct and indirect methods of labeling the hybridization probe equivalent? Total RNA was extracted from human xenograft tissue and amplified using a linear amplification process. RNA was labeled and hybridized, and the resulting images yielded data that was extracted into two categories using the mAdb system: 'all genes' and 'outliers'. Scatter plots were generated for each slide and Pearson Coefficients of correlation were obtained. Results show that the amplification of 5 μg of total RNA yields a Pearson Correlation Coefficient of 0.752 (N = 6,987 genes) between the amplified and total RNA samples. We subsequently determined that amplification of 0.5 μg of total RNA generated a similar Pearson Correlation Coefficient as compared to the corresponding original RNA sample. Similarly, sixty-nine percent of total RNA outliers were detected with 5 μg of amplified starting RNA, and 55% of outliers were detected with 0.5 μg of starting RNA. However, amplification of 0.05 μg of starting RNA resulted in a loss of fidelity (Pearson Coefficient 0.669 between amplified and original samples, 44% outlier concordance). In these studies the direct or indirect methods of probe labeling yielded similar results. Finally, we examined whether RNA obtained from needle core biopsies of human tumor xenografts, amplified and indirectly

  16. Feasibility of computed tomography-guided core needle biopsy in producing state-of-the-art clinical management in Chinese lung cancer.

    Science.gov (United States)

    Chen, Hua-Jun; Yang, Jin-Ji; Fang, Liang-Yi; Huang, Min-Min; Yan, Hong-Hong; Zhang, Xu-Chao; Xu, Chong-Rui; Wu, Yi-Long

    2014-03-01

    A satisfactory biopsy determines the state-of-the-art management of lung cancer in this era of personalized medicine. This study aimed to investigate the suitability and efficacy of computed tomography (CT)-guided core needle biopsy in clinical management. A cohort of 353 patients with clinically suspected lung cancer was enrolled in the study. Patient factors and biopsy variables were recorded. Epidermal growth factor receptor (EGFR) gene mutations and echinoderm microtubule-associated protein-like 4 (EML4)-anaplastic lymphoma kinase (ALK) rearrangement were detected in tumor specimens. Adequacy of biopsic obtainment for clinical trial screening and tissue bank establishment were reviewed. Overall diagnostic accuracy of malignancy achieved 98.5%. The median biopsy time of the cohort was 20 minutes. In patients with non-small cell lung cancer (NSCLC), 99.3% (287/289) were diagnosed as specific histologic subtypes, and two patients (0.7%) were determined as NSCLC not otherwise specified (NOS). EGFR mutations were analyzed in 81.7% (236/289) of patients with NSCLC, and 98.7% (233/236) showed conclusive results. EML4-ALK gene fusion was tested in 43.9% (127/289) of NSCLC patients, and 98.4% (125/127) showed conclusive results: 6.4% (8/125) of those had gene fusion. Ninety-six NSCLC patients participated in clinical trial screening and provided mandatory tumor slides for molecular profiling. Pathological evaluation was fulfilled in 90 patients (93.8%); 99.4% (320/322) of patients with malignancy provided extra tissue for the establishment of a tumor bank. CT-guided core needle biopsy provided optimal clinical management in this era of translational medicine. The biopsic modality should be prioritized in selected lung cancer patients.

  17. Can Confirmatory Biopsy be Omitted in Patients with Prostate Cancer Favorable Diagnostic Features on Active Surveillance?

    Science.gov (United States)

    Satasivam, Prassannah; Poon, Bing Ying; Ehdaie, Behfar; Vickers, Andrew J; Eastham, James A

    2016-01-01

    We evaluated whether initial diagnostic parameters could predict the confirmatory biopsy result in patients initiating active surveillance for prostate cancer, to determine whether some men at low risk for disease reclassification could be spared unnecessary biopsy. The cohort included 392 men with Gleason 6 prostate cancer on initial biopsy undergoing confirmatory biopsy. We used univariate and multivariable logistic regression to assess if high grade cancer (Gleason 7 or greater) on confirmatory biopsy could be predicted from initial diagnostic parameters (prostate specific antigen density, magnetic resonance imaging result, percent positive cores, percent cancer in positive cores and total tumor length). Median patient age was 62 years (IQR 56-66) and 47% of patients had a dominant or focal lesion on magnetic resonance imaging. Of the 392 patients 44 (11%) had high grade cancer on confirmatory biopsy, of whom 39 had Gleason 3+4, 1 had 4+3, 3 had Gleason 8 and 1 had Gleason 9 disease. All predictors were significantly associated with high grade cancer at confirmatory biopsy on univariate analysis. However, in the multivariable model only prostate specific antigen density and total tumor length were significantly associated (AUC 0.85). Using this model to select patients for confirmatory biopsy would generally provide a higher net benefit than performing confirmatory biopsy in all patients, across a wide range of threshold probabilities. If externally validated, a model based on initial diagnostic criteria could be used to avoid confirmatory biopsy in many patients initiating active surveillance. Copyright © 2016 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  18. A study of pathology and clinical findings in cervical lymph node biopsies

    International Nuclear Information System (INIS)

    Asakawa, Takeshi; Yoshida, Shinya; Yoshikawa, Takuma; Kishida, Satoru

    2003-01-01

    We investigated the pathology, age groups, blood test, CT image, isotope findings and fine-needle aspiration biopsy (FNAB) diagnosis in 92 cervical lymph node biopsies. There were 31 cases of benign causes and 61 cases of malignant cases. 18 patients had been treated for malignant disease previously. Of these 18, 17 had had a recurrence of a previous malignant disease. Eleven of the 15 cases that showed an enhancement in the CT examination were malignant. Sensitivity and specificity for malignant etiology in the gallium isotope examination were 91.4% and 37.5%. The hot spot for scintigraphy with 67 Ga was helpful for diagnosis of malignancy. In a total of 8 cases of malignant lymphoma and metastatic lymphoepithelial carcinoma, 5 cases were diagnosed as Class I or II by fine-needle aspiration biopsy. However, there was a hot spot for scintigraphy with 67 Ga in these 5 cases. Therefore, we concluded that the indications of operation in cervical lymph node biopsy are the following: elderly patients with lymphadenopathy that have shown no spontaneous regression for a long time, patients who have been treated for malignant disease previously except for class IV or V, patients who were found to have an enhancement in their CT besides a hot spot for scintigraphy, and suspicion of malignant lymphoma, a hot spot for scintigraphy but in Class I or II. We also investigated 9 cases, 4 men and 5 women aged 13-34 years, with necrotizing lymphadenitis that were correctly diagnosed by biopsy. Antibiotics were not effective in all cases. These patients were improving by taking prednisone after their biopsy. We considered a biopsy necessary in cases where it is difficult to distinguish malignant lymphoma from the effects of prednisone. (author)

  19. Histopathological pattern of abnormal uterine bleeding in endometrial biopsies.

    Science.gov (United States)

    Vaidya, S; Lakhey, M; Vaidya, S; Sharma, P K; Hirachand, S; Lama, S; KC, S

    2013-03-01

    Abnormal uterine bleeding is a common presenting complaint in gyanecology out patient department. Histopathological evaluation of the endometrial samples plays a significant role in the diagnosis of abnormal uterine bleeding. This study was carried out to determine the histopathological pattern of the endometrium in women of various age groups presenting with abnormal uterine bleeding. Endometrial biopsies and curettings of patients presenting with abnormal uterine bleeding was retrospectively studied. A total of 403 endometrial biopsies and curettings were analyzed. The age of the patients ranged from 18 to 70 years. Normal cyclical endometrium was seen in 165 (40.94%) cases, followed by 54 (13.40%) cases of disordered proliferative endometrium and 44 (10.92%) cases of hyperplasia. Malignancy was seen in 10 (2.48%) cases. Hyperplasia and malignancy were more common in the perimenopausal and postmenopausal age groups. Histopathological examination of endometrial biopsies and curettings in patients presenting with abnormal uterine bleeding showed a wide spectrum of changes ranging from normal endometrium to malignancy. Endometrial evaluation is specially recommended in women of perimenopausal and postmenopausal age groups presenting with AUB, to rule out a possibility of any preneoplastic condition or malignancy.

  20. Identification of proteomic biomarkers predicting prostate cancer aggressiveness and lethality despite biopsy-sampling error.

    Science.gov (United States)

    Shipitsin, M; Small, C; Choudhury, S; Giladi, E; Friedlander, S; Nardone, J; Hussain, S; Hurley, A D; Ernst, C; Huang, Y E; Chang, H; Nifong, T P; Rimm, D L; Dunyak, J; Loda, M; Berman, D M; Blume-Jensen, P

    2014-09-09

    Key challenges of biopsy-based determination of prostate cancer aggressiveness include tumour heterogeneity, biopsy-sampling error, and variations in biopsy interpretation. The resulting uncertainty in risk assessment leads to significant overtreatment, with associated costs and morbidity. We developed a performance-based strategy to identify protein biomarkers predictive of prostate cancer aggressiveness and lethality regardless of biopsy-sampling variation. Prostatectomy samples from a large patient cohort with long follow-up were blindly assessed by expert pathologists who identified the tissue regions with the highest and lowest Gleason grade from each patient. To simulate biopsy-sampling error, a core from a high- and a low-Gleason area from each patient sample was used to generate a 'high' and a 'low' tumour microarray, respectively. Using a quantitative proteomics approach, we identified from 160 candidates 12 biomarkers that predicted prostate cancer aggressiveness (surgical Gleason and TNM stage) and lethal outcome robustly in both high- and low-Gleason areas. Conversely, a previously reported lethal outcome-predictive marker signature for prostatectomy tissue was unable to perform under circumstances of maximal sampling error. Our results have important implications for cancer biomarker discovery in general and development of a sampling error-resistant clinical biopsy test for prediction of prostate cancer aggressiveness.