WorldWideScience

Sample records for biopsies quality control

  1. Mapping of transrectal ultrasonographic prostate biopsies: quality control and learning curve assessment by image processing

    CERN Document Server

    Mozer, Pierre; Chevreau, Gregoire; Moreau-Gaudry, Alexandre; Bart, Stephane; Renard-Penna, Raphaele; Comperat, Eva; Conort, Pierre; Bitker, Marc-Olivier; Chartier-Kastler, Emmanuel; Richard, Francois; Troccaz, Jocelyne

    2009-01-01

    Objective: Mapping of transrectal ultrasonographic (TRUS) prostate biopsies is of fundamental importance for either diagnostic purposes or the management and treatment of prostate cancer, but the localization of the cores seems inaccurate. Our objective was to evaluate the capacities of an operator to plan transrectal prostate biopsies under 2-dimensional TRUS guidance using a registration algorithm to represent the localization of biopsies in a reference 3-dimensional ultrasonographic volume. Methods: Thirty-two patients underwent a series of 12 prostate biopsies under local anesthesia performed by 1 operator using a TRUS probe combined with specific third-party software to verify that the biopsies were indeed conducted within the planned targets. RESULTS: The operator reached 71% of the planned targets with substantial variability that depended on their localization (100% success rate for targets in the middle and right parasagittal parts versus 53% for targets in the left lateral base). Feedback from this ...

  2. Biopsies

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Biopsies - Overview A biopsy is the removal of tissue ... What are the limitations of biopsies? What are biopsies? A biopsy is the removal of tissue in ...

  3. 品管圈在减轻患者肾穿刺术前焦虑中的应用%Application of quality control circle(QCC) in patients before renal biopsy

    Institute of Scientific and Technical Information of China (English)

    石敏

    2015-01-01

    目的:探讨品管圈在减轻患者肾穿刺术前焦虑中的应用效果。方法由肾科病区一线护理人员组成品管圈小组,通过头脑风暴,调查分析肾穿刺患者术前焦虑的原因,制定相应的整改措施并组织实施。结果患者肾穿刺术前焦虑由活动前63.3%降低到活动后的23.3%,效果显著( P<0.05);提高了护理人员的创新性、科研性,并提升整个团队的凝聚力和合作力。结论品管圈活动的开展有利于减轻患者肾穿刺术前焦虑。%Objective To investigate the anxiety relieving effect of quality control circle ( QCC ) in patients before renal biopsy.Methods QCC team consisting of nephrology nursing staff, through brainstorming, analyzed the reasons for preoperative anxiety of renal biopsy patients, developed appropriate corrective measures and organized their implementation. Results After the implementation of QCC, the preoperative anxiety incidence of renal biopsy patients decreased from 63.3%to 23.3%, the effect was significant (P<0.05).QCC improved nursing innovation and promoted cohesion and cooperation of the entire team.Conclusions QCC may help reduce the preoperative anxiety of renal biopsy patients.

  4. Needle localization breast biopsy: a model for multidisciplinary quality assurance.

    Science.gov (United States)

    Howe, J R; Monsees, B; Destouet, J; Seib, J; Dehner, L P; Kraybill, W G

    1995-04-01

    As part of the quality assurance role of the Cancer Committee at Barnes Hospital, an institutional audit of Needle Localization Breast Biopsy (NLBB) was performed. Mammographic, operative, and surgical pathology reports from 370 consecutive patients at our institution undergoing both mammography and needle localization biopsy over a 34-month interval were reviewed. Carcinoma was diagnosed pathologically in 103 patients (28%), and 27% of these proved to be noninvasive. Sixteen patients were found to have histologic or clinical involvement of the axillary nodes; no patients with Tis lesions were found to have axillary nodal involvement. Of the patients, 73% were found to have either Stage 0 or Stage I disease, and 61% with an established malignancy had mastectomy (67% of patients with invasive carcinoma, 44% of those with carcinoma-in-situ), whereas 39% had some form of conservation therapy (33% of patients with invasive lesions, 56% of those with carcinoma-in-situ). Our results have been compared with other published studies, and important clinical indicators for evaluating the results of individual centers performing NLBB are discussed. It is concluded that NLBB is a safe and effective method of biopsying nonpalpable breast lesions, which allows for the identification of early stage breast carcinomas. In the present environment of concerns about the quality of care and costs, it is the responsibility of each center performing NLBB periodically to evaluate their results with this multidisciplinary procedure and to bring about change in those areas found to be deficient. PMID:7723366

  5. Endoscopic biopsy as quality assurance for endoscopic services.

    Directory of Open Access Journals (Sweden)

    King-Wah Chiu

    Full Text Available Gastroendoscopy (GS procedures are not only performed by gastroenterologists (GE but also by hepatologists (HT in many countries. Endoscopic biopsy (EBx remains the gold standard for the investigation and documentation of esophago-gastro-duodenal pathology. EBx is subjectively performed by an endoscopist, and the level of skill and experience of the endoscopist may affect the quality of the endoscopic service. Reasons for this discrepancy included lack of experience practitioners to order EBx when required of GS issues between in GE and HT limit access. Ideally, services should be safe and of high quality. This study assessed the EBx/GS ratio as the endoscopic quality assurance as an index of GS services. This was a cohort study of endoscopists at Kaohsiung Chang Gung Memorial Hospital, a teaching hospital in southern Taiwan. There were 34,570 episodes of EBx in 199,877 GS procedures. The 25 endoscopists were divided into GE (n = 13 and HT (n = 12 groups, and correlation coefficients were calculated over a 14.5-year duration of intervention. The Trimmean of EBx/GS was 19.29% in 14.5 years (34570/199877 with Trimmean 0.2 percentile ratio correlations, and the Pearson correlation coefficient was 0.90229. There were significantly more EBx procedures in the GE group than in the HT group at 1 and 5 years (21.5% vs. 15.1% and 20.9% vs. 17.3%, respectively, P<0.00001. Junior GE attempted significantly more EBx than both the senior GE (24.06% vs. 20.41%, P<0.0001, and junior HT (24.06% vs. 13.2%, P<0.0001. In conclusion, quality assurance for gastrointestinal endoscopy involves numerous aspects of unit management and patient safety. Quality measures used with the EBx/GS ratio may be one of the best ways to ensure the quality of endoscopic procedures in a teaching hospital.

  6. [Does the mounting of gastrointestinal biopsies on millipore filter contribute to an improved section quality?

    DEFF Research Database (Denmark)

    Asmussen, L.; Bernstein, I.; Matzen, P.;

    2009-01-01

    INTRODUCTION: The quality of the histological sections of gastrointestinal biopsies (GIB) affects the diagnostic possibilities. One aspect is the orientation of GIB, whereby sectioning perpendicular to the mucosal surface can be performed more readily. With the purpose to achieve correct orientat......INTRODUCTION: The quality of the histological sections of gastrointestinal biopsies (GIB) affects the diagnostic possibilities. One aspect is the orientation of GIB, whereby sectioning perpendicular to the mucosal surface can be performed more readily. With the purpose to achieve correct...

  7. Diagnosing non-palpable breast disease : short-term impact on quality of life of large-core needle biopsy versus open breast biopsy

    NARCIS (Netherlands)

    Verkooijen, HM; Buskens, E; Peeters, PHM; Rinkes, IHMB; de Koning, HJ; van Vroonhoven, TJMV

    2002-01-01

    Background: One of the alleged advantages of stereotactic large-core needle biopsy of non-palpable breast lesions is that it entails less inconvenience for the patient. In this prospective study, the quality of life of patients undergoing large-core needle biopsy was compared with that of patients u

  8. Quality Control Applications

    CERN Document Server

    Chorafas, Dimitris N

    2013-01-01

    Quality control is a constant priority in electrical, mechanical, aeronautical, and nuclear engineering – as well as in the vast domain of electronics, from home appliances to computers and telecommunications. Quality Control Applications provides guidance and valuable insight into quality control policies; their methods, their implementation, constant observation and associated technical audits. What has previously been a mostly mathematical topic is translated here for engineers concerned with the practical implementation of quality control. Once the fundamentals of quality control are established, Quality Control Applications goes on to develop this knowledge and explain how to apply it in the most effective way. Techniques are described and supported using relevant, real-life, case studies to provide detail and clarity for those without a mathematical background. Among the many practical examples, two case studies dramatize the importance of quality assurance: A shot-by-shot analysis of the errors made ...

  9. Software product quality control

    CERN Document Server

    Wagner, Stefan

    2013-01-01

    Quality is not a fixed or universal property of software; it depends on the context and goals of its stakeholders. Hence, when you want to develop a high-quality software system, the first step must be a clear and precise specification of quality. Yet even if you get it right and complete, you can be sure that it will become invalid over time. So the only solution is continuous quality control: the steady and explicit evaluation of a product's properties with respect to its updated quality goals.This book guides you in setting up and running continuous quality control in your environment. Star

  10. Local anesthesia for pain control during transrectal ultrasound-guided prostate biopsy: a systematic review and meta-analysis

    Directory of Open Access Journals (Sweden)

    Yan P

    2016-10-01

    reported general or local complications related to local anesthesia.Conclusion: This meta-analysis indicates that a combination of PPNB and IRLA/IPNB is effective and safe in alleviating the pain during TRUS-guided prostate biopsy. Further high-quality RCTs are needed to validate this result. Keywords: local anesthesia, biopsy, meta-analysis, pain control, prostate

  11. [Quality control in anesthesiology].

    Science.gov (United States)

    Muñoz-Ramón, J M

    1995-03-01

    The process of quality control and auditing of anesthesiology allows us to evaluate care given by a service and solve problems that are detected. Quality control is a basic element of care giving and is only secondarily an area of academic research; it is therefore a meaningless effort if the information does not serve to improve departmental procedures. Quality assurance procedures assume certain infrastructural requirements and an initial period of implementation and adjustment. The main objectives of quality control are the reduction of morbidity and mortality due to anesthesia, assurance of the availability and proper management of resources and, finally, the well-being and safety of the patient. PMID:7777688

  12. Checking quality control?

    DEFF Research Database (Denmark)

    Brodersen, Lars

    2005-01-01

    How is quality control doing within the community of GIS, web-services based on geo-information, GI etc.?......How is quality control doing within the community of GIS, web-services based on geo-information, GI etc.?...

  13. Evaluation of an interactive breath-hold control system in CT-guided lung biopsy

    International Nuclear Information System (INIS)

    Purpose: In this study we assessed the effect of an interactive breath-hold control system on procedure time and technical success in transthoracic CT-guided lung biopsies. Materials and Methods: in 36 patients (4 female, 32 male, mean age 65 years; range 33 - 88) with a pulmonary nodule, we performed CT-guided biopsy using a 18G Tru-cut needle (Cardinal Health, Dublin, UK) in a 64 row dual-source CT scanner (Somatom Definition, Siemens, Forchheim, Germany) using intermittent imaging of the needle. In half of the patients (2 female, 16 male, mean age 67 years), an interactive breathhold control system (IBC) (Mayo Clinic Medical Devices, USA) was applied. No additional device was used in the control group. Results: the biopsy was visually successful in all patients. The diameter of the target lesion was comparable in both groups (IBC: 30 ± 19 mm; control: 28 ± 15 mm). The number of imaging steps was significantly smaller (p < 0.05) and the intervention time was significantly shorter (p < 0.05) in the IBC group (IBC: 9 ± 5 steps 17 ± 10 min; control: 13 ± 5 steps 26 ± 12 min). Conclusion: application of the IBC unit reduced the intervention time and radiation exposure in CT-guided Tru-cut biopsy of pulmonary nodules. (orig.)

  14. Quality control of radiopharmaceuticals

    International Nuclear Information System (INIS)

    Quality assurance was introduced in the pharmaceutical field long before it was used in many other areas, and the term quality control has been used in a much broader sense than merely analytical quality control. The term Good Manufacturing Practice (GMP) has been used to describe the system used for producing safe and effective drugs of a uniform quality. GMP has also been used for the industrial production of radiopharmaceuticals. For the preparation and control of radiopharmaceuticals in hospitals a similar system has been named Good Radiopharmacy Practice (GRP). It contains the same elements as GMP but takes into account the special nature of this group of drugs. Data on the assessment of the quality of radiopharmaceuticals in relation to present standards are reviewed. The general conclusion is that the quality of radiopharmaceuticals appears comparable to that of other drugs. It seems possible to establish the production of radiopharmaceuticals, generators and preparation kits in such a way that analytical control of the final product at the hospital may be limited provided the final preparation work is carried out in accordance with GRP principles. The elements of GRP are reviewed. (author)

  15. Quality Management, Quality Assurance and Quality Control in Blood Establishments

    OpenAIRE

    Bolbate, N

    2008-01-01

    Quality terms and the roots of the matter are analyzed according to European Committee’s recommendations. Essence of process and product quality control as well as essence of quality assurance is described. Quality system’s structure including quality control, quality assurance and management is justified in the article.

  16. Bone Biopsy

    Science.gov (United States)

    ... Physician Resources Professions Site Index A-Z Bone Biopsy Bone biopsy uses a needle and imaging guidance ... limitations of Bone Biopsy? What is a Bone Biopsy? A bone biopsy is an image-guided procedure ...

  17. Effect of endometrial biopsy on intrauterine insemination outcome in controlled ovarian stimulation cycle

    OpenAIRE

    Leena Wadhwa; Amrita Pritam; Taru Gupta; Sangeeta Gupta; Sarika Arora; Rajkumar Chandoke

    2015-01-01

    OBJECTIVE: The objective was to evaluate the effect of endometrial biopsy (EB) on intrauterine insemination (IUI) outcome in controlled ovarian stimulation (COS) cycle. DESIGN: Prospective randomized control study. SETTING: Tertiary care center. MATERIALS AND METHODS: A total of 251 subjects were enrolled in the study. Subjects undergoing COS with IUI were randomly allocated into three groups. Group A: EB was taken between D19 and 24 of the spontaneous menstrual cycles that precedes the ferti...

  18. MR imaging-guided vacuum-assisted breast biopsy: Reduction of false-negative biopsies by short-term control MRI 24–48 h after biopsy

    International Nuclear Information System (INIS)

    Aim: To evaluate whether another contrast-enhanced (CE) magnetic resonance imaging (MRI) examination 24–48 h after MRI-guided vacuum-assisted breast biopsy (MRI-VAB) can reduce the rate of false-negative cases. Materials and methods: The study included 252 patients who underwent MRI-VAB for the clarification of 299 lesions. The success of MRI-VAB was assessed at interventional MRI and another CE MRI 24–48 h after the intervention. In cases of successful MRI-VAB (complete or partial lesion removal) and benign histological results, follow-up breast MRI was performed. In cases of unsuccessful biopsy (unchanged lesion), tissue sampling was repeated. False-negative cases were calculated to assess the diagnostic value of MRI follow-up within 2 days after intervention. Results: Ninety-eight malignant (32.8%) and 201 (67.2%) benign lesions were diagnosed using MRI-VAB. At immediate unenhanced control MRI, all lesions were assessed as successfully biopsied. In 18 benign cases (6%), CE MRI after 24–48 h showed an unsuccessful intervention. Further tissue sampling revealed another 13 cancers in these patients. This results in a false-negative rate of 11.7%. Follow-up MRI of the benign lesions presented no further malignancy. Conclusions: MRI-VAB with immediate unenhanced control offers a success rate of 94%. The rate of false-negative biopsies (11.7%) could be reduced to zero by using short-term follow-up MRI. Therefore, a further CE breast MRI 24–48 h after benign MRI-VAB to eliminate missed cancers is recommended. - Highlights: • Some suspicious breast lesions are only seen on MRI. • They can be biopsied by a MRI-guided vacuum-assisted biopsy system. • Inadequate sampling causes some false-negative biopsies. • We evaluate an additional control MRI 24 to 48 hours after biopsy. • A reduced rate of the false-negative biopsies was found

  19. VGI QUALITY CONTROL

    Directory of Open Access Journals (Sweden)

    C. C. Fonte

    2015-08-01

    Full Text Available This paper presents a framework for considering quality control of volunteered geographic information (VGI. Different issues need to be considered during the conception, acquisition and post-acquisition phases of VGI creation. This includes items such as collecting metadata on the volunteer, providing suitable training, giving corrective feedback during the mapping process and use of control data, among others. Two examples of VGI data collection are then considered with respect to this quality control framework, i.e. VGI data collection by National Mapping Agencies and by the most recent Geo-Wiki tool, a game called Cropland Capture. Although good practices are beginning to emerge, there is still the need for the development and sharing of best practice, especially if VGI is to be integrated with authoritative map products or used for calibration and/or validation of land cover in the future.

  20. Sentinel node biopsy in breast cancer: short time results show appropriate regional control.

    Science.gov (United States)

    Fait, V; Chrenko, V

    2007-01-01

    Sentinel node biopsy becomes a standard diagnostic and therapeutic tool in breast cancer in certain indications, while in other indications its validity is still reviewed. The authors present their experience with this method. In the years 2000-2006 700 patients underwent surgery. 704 sentinel node biopsies were performed (bilaterally in 4 cases), 7 times surgery was unsuccessful. In the unsuccessful cases immediate axillary lymph node dissection (ALND) was performed. 985 sentinel nodes were found, the average was 1.4 nodes, maximum 6 nodes. In 7 patients contralateral ALND for node positive contralateral cancer was necessary along with sentinel node biopsy. A positive sentinel lymph node (SLN) was found in 188 (26.9%) patients. A strong correlation between tumor size and lymph node positivity was found, 5.3% in pT1a, and 40.4% in pT2, respectively. The sentinel node metastases could be divided according to their size. The number of affected further nodes did correlate with this size, yet with the exception of isolated tumor cell detection, small size metastases did not exclude the possibility of further affection. Our findings support the role of sentinel node biopsy in breast cancer. 332 patients reached at least 2 years of follow up by the time of statistic evaluation, 2.5% of SLN negative and 5.6% of SLN positive patients experienced a recurrence. All of these recurrences were distant with no regional (axillary) involvement to this date. We conclude that sentinel node biopsy is not only a safe and accurate diagnostic tool, but it also provides acceptable regional control of the disease. PMID:17447860

  1. Massive rectal bleeding after prostate biopsy controlled by endoclipping in a patient using acetylsalicylic acid

    OpenAIRE

    Özveren, Bora; Türkeri, Levent

    2013-01-01

    A case of severe rectal bleeding following transurethral ultrasound (TRUS)-guided prostate biopsy is reported. Rectal bleeding is considered a minor, transient complication of this standard diagnostic procedure that can usually be controlled successfully by conservative measures. In this case where the patient had been taking acetylsalicylic acid (ASA), massive bleeding required hospitalization and blood transfusions. Conservative treatment attempts were not succesful, and profuse rectal blee...

  2. Raman-based detection of hydroxyethyl starch in kidney allograft biopsies as a potential marker of allograft quality in kidney transplant recipients

    Science.gov (United States)

    Vuiblet, Vincent; Fere, Michael; Bankole, Ezechiel; Wynckel, Alain; Gobinet, Cyril; Birembaut, Philippe; Piot, Olivier; Rieu, Philippe

    2016-01-01

    In brain-dead donor resuscitation, hydroxyethyl starch (HES) use has been associated with presence of osmotic-nephrosis-like lesions in kidney transplant recipients. Our aim was to determine whether the presence of HES in protocol renal graft biopsies at three months (M3) after transplantation is associated with renal graft quality. According to the HES administered to the donor during the procurement procedure, two groups of patients were defined according graft exposition to HES: HES group, (N = 20) and control group (N = 6). Detection and relative quantification of HES was performed by Raman spectroscopy microimaging on M3 protocol renal graft biopsies. Statistical analyses were used to investigate the association between Raman data and graft characteristics. HES spectral signal was revealed negative in the control group, whereas it was positive in 40% of biopsies from the HES group. In the HES group, a stronger HES signal was associated with a lower risk of graft failure measured by the Kidney Donor Risk Index (KDRI) and was correlated with the allograft kidney function. Thus, HES accumulation in donor kidney, as probed by Raman biophotonic technique, is correlated with the quality of donor kidney and consequently the graft renal function and graft survival. PMID:27608775

  3. Gum biopsy

    Science.gov (United States)

    Biopsy - gingiva (gums) ... used to close the opening created for the biopsy. ... to eat for a few hours before the biopsy. ... Risks for this procedure include: Bleeding from the biopsy site Infection of the gums Soreness

  4. Optimizing control of quality management

    OpenAIRE

    Fliginskih Tatyana Nikolayevna; Fedoretc Ksenia Sergeevna

    2012-01-01

    This paper describes the technology that permits controlling of business processes in industry. An example of the use of control charts as one of the most effective methods of statistical quality control of products. The author provides a definition that best reveals the understanding of quality and quality control.

  5. The effectivity of periprostatic nerve blockade for the pain control during transrectal ultrasound guided prostate biopsy

    Directory of Open Access Journals (Sweden)

    Alper Otunctemur

    2013-06-01

    Full Text Available Aim: Transrectal ultrasound (TRUS guided prostete biopsy is accepted as a standard procedure in the diagnosis of prostate cancer. Many different protocoles are applied to reduce the pain during the process. In this study we aimed to the comparison of two procedure with intrarectal lidocaine gel and periprostatice nerve blockade respective- ly in addition to perianal intrarectal lidocaine gel on the pain control in prostate biop- sy by TRUS. Methods: 473 patients who underwent prostate biopsy guided TRUS between 2008-2012 were included in the study. 10-point linear visual analog pain scale(VAS was used to evaluate the pain during biopsy. The patients were divided into two groups according to anesthesia procedure. In Group 1, there were 159 patients who had perianal-intrarectal lidocaine gel, in Group 2 there were 314 patients who had periprostatic nerve blockade in addition to intrarectal lidocain gel. The pain about probe manipulation was aseesed by VAS-1 and during the biopsy needle entries was evalu- ated by VAS-2. Results were compared with Mann-Whitney U and Pearson chi-square test. Results: Mean VAS-2 scores in Group 1 and Group 2 were 4.54 ± 1.02 and 2.06 ± 0.79 respectively. The pain score was determined significantly lower in the Group 2 (p = 0.001. In both groups there was no significant difference in VAS-1 scores, patient’s age, prostate volume, complication rate and PSA level. Conclusion: The combination of periprostatic nerve blockade and intrarectal lidocain gel provides a more meaningful pain relief compared to group of patients undergoing intrarectal lidocaine gel.

  6. Quality control in audit firm

    OpenAIRE

    Dostálová, Milena

    2008-01-01

    Thesis deals with the quality control of audit firms in accordance with international regulations. Defining the requirements for quality based on the Code of Ethics and the International quality standard ISQC1. Part of this work is the practical demonstration of ISQC1 in the smaller audit firm. For comparison, there is a description of quality control in the U.S.

  7. Biopsy-controlled liver fibrosis staging using the enhanced liver fibrosis (ELF score compared to transient elastography.

    Directory of Open Access Journals (Sweden)

    Kristin Wahl

    Full Text Available BACKGROUND AND AIMS: Chronic liver diseases are characterized by inflammatory and fibrotic liver injuries that often result in liver cirrhosis with its associated complications such as portal hypertension and hepatocellular carcinoma. Liver biopsy still represents the reference standard for fibrosis staging, although transient elastography is increasingly used for non-invasive monitoring of fibrosis progression. However, this method is not generally available and is associated with technical limitations emphasizing the need for serological biomarkers staging of liver fibrosis. The enhanced liver fibrosis (ELF score was shown to accurately predict significant liver fibrosis in different liver diseases, although extracellular matrix components detected by this score may not only mirror the extent of liver fibrosis but also inflammatory processes. METHODS: In this prospective biopsy-controlled study we evaluated the utility of the ELF score in comparison to transient elastography to predict different stages of fibrosis in 102 patients with chronic liver diseases. RESULTS: Both techniques revealed similar area under receiver operating characteristic curve values for prediction of advanced fibrosis stages. Compared to transient elastography, the ELF score showed a broader overlap between low and moderate fibrosis stages and a stronger correlation with inflammatory liver injury. CONCLUSIONS: Both the ELF score as well as transient elastography allowed for high quality fibrosis staging. However, the ELF score was less discriminative in low and moderate fibrosis stages and appeared more strongly influenced by inflammatory liver injury. This should be considered when making clinical interpretations on the basis of ELF score values.

  8. The effects of continuous quality improvement on renal biopsy nursing%持续质量改进在肾活检护理中的应用

    Institute of Scientific and Technical Information of China (English)

    李霞

    2011-01-01

    Objective To investigate the effects of continuous quality improvement (CQI)on renal biopsy nursing. Methods Eighty - five patients were divided into control group(45 patients) and observed group(40 patients). Control group patients were given ordinary nursing, observed group were given CQI mode nursing. Nursing problems were evaluated in the process of renal biopsy, and the reasons of these problems were analysed, improvement target was enacted. Steps were taken according to the target. Specific measures were laid out, the effect was appraised. Result The nursing effect of the control group is much better than the observed group. Conclusions Continuous quality improvement application on renal biopsy nursing reduced complications, ensured the patients' safety, improved nursing service quality, and reflected people- first service philosophy.%目的 探讨肾活检护理中持续质量改进(CQI)的应用效果.方法 将85例患者分为对照组45例和观察组40例,对照组按常规护理,观察组采用CQI模式进行护理,评估肾活检过程中存在的护理问题并进行分析,制定改进目标,并根据目标采取措施.制定具体实施步骤,并评价措施产生的效果.结果 观察组的护理效果显著优于对照组.结论肾活检护理中采用持续质量改进,减少了肾活检术后并发症,保证患者安全,提高了护理服务质量,体现了以人为本的护理理念.

  9. Assessing the safety and quality of ward-based renal transplant biopsies

    Directory of Open Access Journals (Sweden)

    Kenneth Wu

    2010-10-01

    Full Text Available Kenneth Wu1, Bindhu Musunuru1, Chera Arunachalam1, Aung Sett1, Paul Musker21Renal Unit, St James’ University Hospital, Leeds, West Yorkshire, UK; 2Renal Unit, St Luke’s Hospital, Bradford, West Yorkshire, UKAbstract: The aim of this pilot study was to compare renal transplant biopsies carried out by ward-based nephrology trainees and departmental based radiologists, primarily reviewing major complications and glomerular yield. There was only one patient who developed a single episode of major complication out of the 145 procedures recorded. We concluded there is no significant difference in complication rate and glomerular yield for renal allograft biopsies between nephrology trainees and radiologists, regardless of location.Keywords: renal transplant, kidney biopsy complications, renal hemorrhage, glomerular yield

  10. Accuracy of Colposcopically Directed Biopsy: Results from an Online Quality Assurance Programme for Colposcopy in a Population-Based Cervical Screening Setting in Italy

    Directory of Open Access Journals (Sweden)

    Mario Sideri

    2015-01-01

    Full Text Available Purpose. To report the accuracy of colposcopically directed biopsy in an internet-based colposcopy quality assurance programme in northern Italy. Methods. A web application was made accessible on the website of the regional Administration. Fifty-nine colposcopists out of the registered 65 logged in, viewed a posted set of 50 digital colpophotographs, classified them for colposcopic impression and need for biopsy, and indicated the most appropriate site for biopsy with a left-button mouse click on the image. Results. Total biopsy failure rate, comprising both nonbiopsy and incorrect selection of biopsy site, was 0.20 in CIN1, 0.11 in CIN2, 0.09 in CIN3, and 0.02 in carcinoma. Errors in the selection of biopsy site were stable between 0.08 and 0.09 in the three grades of CIN while decreasing to 0.01 in carcinoma. In multivariate analysis, the risk of incorrect selection of biopsy site was 1.97 for CIN2, 2.52 for CIN3, and 0.29 for carcinoma versus CIN1. Conclusions. Although total biopsy failure rate decreased regularly with increasing severity of histological diagnosis, the rate of incorrect selection of biopsy site was stable up to CIN3. In multivariate analysis, CIN2 and CIN3 had an independently increased risk of incorrect selection of biopsy site.

  11. Skin Biopsy

    Science.gov (United States)

    ... skin condition cannot be diagnosed by the patient's history and what the physician finds on examination alone. Confirming a clinical diagnosis may also be necessary prior to starting therapy. Skin biopsy types are as follows: Shave biopsies Punch biopsies ...

  12. Liver biopsy

    Science.gov (United States)

    Biopsy - liver; Percutaneous biopsy ... the biopsy needle to be inserted into the liver. This is often done by using ultrasound. The ... the chance of damage to the lung or liver. The needle is removed quickly. Pressure will be ...

  13. Biopsy - polyps

    Science.gov (United States)

    Polyp biopsy ... are treated is the colon. How a polyp biopsy is done depends on the location: Colonoscopy or flexible sigmoidoscopy explores the large bowel Colposcopy-directed biopsy examines the vagina and cervix Esophagogastroduodenoscopy (EGD) or ...

  14. Nerve biopsy

    Science.gov (United States)

    Biopsy - nerve ... A nerve biopsy is most often done on a nerve in the ankle, forearm, or along a rib. The health care ... feel a prick and a mild sting. The biopsy site may be sore for a few days ...

  15. Endometrial biopsy

    Science.gov (United States)

    Biopsy - endometrium ... The biopsy is normal if the cells in the sample are not abnormal. ... Risks of endometrial biopsy include: Infection Causing a hole in (perforating) the uterus or tearing the cervix (rarely occurs) Prolonged bleeding Slight spotting ...

  16. Quality control of radioisotopic products

    International Nuclear Information System (INIS)

    Radiopharmaceutical quality control is a very comprehensive and responsible activity since it concerns products being used for the health care of patients. Quality control is practised by an analytical specialist in close cooperation with pharmacists who are responsible for routine quality assurance. There is also a good understanding with the production group to ensure high-quality products. Quality control also relies on the research and development group to investigate problems. Finally there is feedback from the user since he is also responsible for quality control in a limited way. The scope of quality control is comprehensive, e.g. physical inspection and chemical control of all inactive starting material including supervision of the various stages of production. The quality control of radioactive material includes nuclidic analysis, verification of radiochemical purity as well as regular stability checks. Biological controls comprise sterility tests both on final products and production environment; testing for toxicity, pyrogens and LD50 values. To test product efficacy it is imperative to rely on biodistribution. Rabbits are used for quality control screening in a qualitative static mode and the dissection of mice organs is carried out for time-consuming quantitative analyses. Since radiopharmaceuticals are being used in a dynamic mode by nuclear medicine, their quality control tests on animals should, for proper evaluation, be carried out by means of comparative studies with imported products and by using a high-resolution camera with computer facilities. The Group for Quality Control and Assurance is responsible for an extensive documentation system which ensures both good manufacturing practice and effective analytical tests. Through quality control the specialist is constantly striving for improvement to ensure a good product for the benefit of the patient

  17. NI-24IMPROVING BIOBANKED SPECIMEN QUALITY: LABEL-FREE MICROSCOPIC ASSESSMENT OF HUMAN BRAIN TUMOR BIOPSIES PRIOR TO BIOBANKING

    Science.gov (United States)

    Eschbacher, Jennifer; Georges, Joseph; Zehri, Aqib; Mooney, Michael; Carlson, Elizabeth; Nichols, Joshua; Farhat, Kalil; Anderson, Trent; Preul, Mark; Jensen, Kendall; Nakaji, Peter

    2014-01-01

    INTRODUCTION: Biobanked brain tumor specimens share a critical shortcoming: the inability to efficiently screen tissue specimens prior to banking, potentially leading to storage of poor-quality samples. Standard histologic approaches to evaluate cellularity of tissue, such as frozen sectioning, may alter molecular characteristics and damage tissue for downstream analyses. Here, utilizing a novel ex vivo approach, we evaluate the feasibility of interrogating tissue cellularity and cytoarchitecture with label-free confocal reflectance microscopy (CRM) prior to biobanking. METHODS: Biopsies from patients with intracranial neoplasms (n = 3 for each; glioma, meningioma, pituitary adenoma, and schwannoma) were transported to the pathology department and placed in ice-cold saline. Samples were immediately positioned on the stage of our pathology-based Zeiss LSM710 confocal microscope and visualized with CRM. CRM images were evaluated for tumor cellularity, architecture and morphology, and then compared to corresponding permanent sections. RESULTS: CRM could contrast cellularity and stroma in all samples, as compared to corresponding permanent sections. Additionally, CRM contrasted vasculature and regions of necrosis in glioblastomas, tumor architecture in meningiomas and schwannomas, and sheets of neoplastic cells in pituitary ademonas. DISCUSSION: We found confocal reflectance microscopy to be a simple approach to screening biospecimens prior to biobanking. CRM quickly generated distinct ex vivo microscopic images from biopsies without tissue processing or application of exogenous dyes. CRM contrasted histopathological features present in our samples, and produced images that could be digitally stored and recalled with the matched specimen in the biobank. In our previous studies, we reported CRM did not alter the molecular integrity of fresh biopsies from brain tumor animal models. We hypothesize that wider use of this technique could improve the quality of banked tissue.

  18. Frontiers in statistical quality control

    CERN Document Server

    Wilrich, Peter-Theodor

    2004-01-01

    This volume treats the four main categories of Statistical Quality Control: General SQC Methodology, On-line Control including Sampling Inspection and Statistical Process Control, Off-line Control with Data Analysis and Experimental Design, and, fields related to Reliability. Experts with international reputation present their newest contributions.

  19. Quality assurance programme and quality control

    International Nuclear Information System (INIS)

    The paper analyses the requirements for the quality assurance and control in nuclear power plant projects which are needed to achieve safe, reliable and economic plants. The author describes the structure for the establishment of a nuclear programme at the national level and the participation of the different bodies involved in a nuclear power plant project. The paper ends with the study of a specific case in Spain. (NEA)

  20. Tongue biopsy

    Science.gov (United States)

    Biopsy - tongue ... A tongue biopsy can be done using a needle. You will get numbing medicine at the place where the ... provider will gently stick the needle into the tongue and remove a tiny piece of tissue. Some ...

  1. Parathyroid biopsy

    Science.gov (United States)

    ... Feel The test feels like a quick needle jab or stick. You may feel a sting as ... activities the same day. Alternative Names Biopsy - parathyroid Images Endocrine glands Parathyroid biopsy References Pellitteri PK, Sofferman ...

  2. Quality control of labelled compounds

    International Nuclear Information System (INIS)

    Some advantages and disadvantages of methods used for quality control of organic labelled compounds (131I, 14C) are shortly discussed. The methods used are electrophoresis, ultraviolet and infrared spectrometry, radiogas and thin-layer chromatography. (author)

  3. CA Water Quality Control Board

    Data.gov (United States)

    U.S. Environmental Protection Agency — Regional Water Quality Control Boards(9) in California. These district boundaries coincide with the boundaries of some of the hydrologic study areas delineated by...

  4. TRANSRECTAL ULTRASOUND GUIDED PROSTATIC NERVE BLOCKADE FOR PAIN CONTROL DURING TRANSRECTAL PROSTATE BIOPSY

    Institute of Scientific and Technical Information of China (English)

    YANG Liu-ping; DENG Jun-hong; ZHONG Hong; HU Jian-bo; WEI Hong-ai; WANG Liang-sheng

    2005-01-01

    Objective: To assess the effect of transrectal ultrasound guided prostatic nerve blockade on the discomfort associated with systematic biopsy of the prostate. Methods: 73 patients receiving systematic 13 cores biopsy of the prostate were randomized into two groups. Group A(37 cases) received an injection of 5 ml 1% lidocaine into the prostatic neurovascular bundles on each side at the base of the prostate under ultrasound guidance and group B(36 cases) received 5 ml saline injection (0.9% sodium chloride) at the same site. Pain during biopsy was assessed by using a 10-point linear visual analog score (VAS) immediately after the biopsy. Results: The mean pain scores during transrectal prostate biopsy were significantly lower in group A than group B(1.1±0.6 versus 5.9±3.1, t=4.81, P<0.01). During this study no patient in either group had any adverse effect from the injection. Conclusion: Transcrectal ultrasound guided prostatic nerve blockade is a safe and efficacious method for providing satisfactory anesthesia in transrectal prostate biopsy. We recommend its routine administration in all patients during this procedure.

  5. SAQC: SNP Array Quality Control

    Directory of Open Access Journals (Sweden)

    Li Ling-Hui

    2011-04-01

    Full Text Available Abstract Background Genome-wide single-nucleotide polymorphism (SNP arrays containing hundreds of thousands of SNPs from the human genome have proven useful for studying important human genome questions. Data quality of SNP arrays plays a key role in the accuracy and precision of downstream data analyses. However, good indices for assessing data quality of SNP arrays have not yet been developed. Results We developed new quality indices to measure the quality of SNP arrays and/or DNA samples and investigated their statistical properties. The indices quantify a departure of estimated individual-level allele frequencies (AFs from expected frequencies via standardized distances. The proposed quality indices followed lognormal distributions in several large genomic studies that we empirically evaluated. AF reference data and quality index reference data for different SNP array platforms were established based on samples from various reference populations. Furthermore, a confidence interval method based on the underlying empirical distributions of quality indices was developed to identify poor-quality SNP arrays and/or DNA samples. Analyses of authentic biological data and simulated data show that this new method is sensitive and specific for the detection of poor-quality SNP arrays and/or DNA samples. Conclusions This study introduces new quality indices, establishes references for AFs and quality indices, and develops a detection method for poor-quality SNP arrays and/or DNA samples. We have developed a new computer program that utilizes these methods called SNP Array Quality Control (SAQC. SAQC software is written in R and R-GUI and was developed as a user-friendly tool for the visualization and evaluation of data quality of genome-wide SNP arrays. The program is available online (http://www.stat.sinica.edu.tw/hsinchou/genetics/quality/SAQC.htm.

  6. Prostate biopsy tracking with deformation estimation

    CERN Document Server

    Baumann, Michael; Daanen, Vincent; Troccaz, Jocelyne

    2011-01-01

    Transrectal biopsies under 2D ultrasound (US) control are the current clinical standard for prostate cancer diagnosis. The isoechogenic nature of prostate carcinoma makes it necessary to sample the gland systematically, resulting in a low sensitivity. Also, it is difficult for the clinician to follow the sampling protocol accurately under 2D US control and the exact anatomical location of the biopsy cores is unknown after the intervention. Tracking systems for prostate biopsies make it possible to generate biopsy distribution maps for intra- and post-interventional quality control and 3D visualisation of histological results for diagnosis and treatment planning. They can also guide the clinician toward non-ultrasound targets. In this paper, a volume-swept 3D US based tracking system for fast and accurate estimation of prostate tissue motion is proposed. The entirely image-based system solves the patient motion problem with an a priori model of rectal probe kinematics. Prostate deformations are estimated with ...

  7. Quality Evaluation of Cone Biopsy Specimens Obtained by Large Loop Excision of the Transformation Zone

    Science.gov (United States)

    Garcia Ramos, Aristoteles Mauricio; Garcia Ramos, Erika Souza; dos Reis, Helena Lucia Barroso; de Rezende, Ricardo Bueno

    2015-01-01

    Background Large loop excision of the transformation zone (LLETZ) has been used for the diagnosis and treatment of precancerous cervical lesions, and it is the first choice of treatment in the majority of cervical pathology services. The aim of this study was to evaluate the presence of thermal artifacts, the need for serial sections, the percentage of clear and involved resection margins and the relationship between endocervical gland involvement and the severity of the lesion in samples resected using LLETZ. Methods A retrospective study was performed at Santa Casa de Misericordia School of Science (HSCMV), Vitoria, Espirito Santo, Brazil with a sample of 52 histopathology slides from patients submitted to conization because of abnormal cytology findings and a biopsy result of cervical intraepithelial neoplasia (CIN) 2, CIN 3 and adenocarcinoma in situ. Statistical analysis was performed using Student’s t-test. Results Serial sections were required to confirm diagnosis in four of 52 cases. Thermal artifacts were present in all cases, with grade I being the most common (94.2% of cases). Clear margins were found in 96.2% of cases. No association was found between glandular involvement and CIN 1 (P > 0.05); however, there was an association with CIN 2 and CIN 3 (P < 0.05). Conclusion The amount of excised tissue was sufficient, thermal artifacts were slight, resection margins were clear in most of cases, and a possible association was found between glandular involvement and the severity of the lesion. PMID:25699117

  8. The biopsy of the boar testes using ultrasonographic examination

    Directory of Open Access Journals (Sweden)

    Laima Liepa

    2014-03-01

    Full Text Available The biopsy of live animal testes is an important clinical manipulation to control spermatogenesis and reproductive system pathologies. The aim was to develop a method of boar testes biopsy using a biopsy gun with ultrasound guidance and to investigate the influence of this procedure on the boar testes parenchyma and quality of ejaculate. The biopsy was carried out in six 8-month-old boars. Fourteen days prior to and 21 days after biopsy, the quality of ejaculate was examined (weight of ejaculate; concentration and motility of spermatozoa with a seven-day intervals. Ultrasound images of the testes parenchyma were recorded three times: directly before and 15 minutes after the biopsy, then 21 days after the procedure. The testes biopsies of generally anesthetized boars were performed with the biopsy gun for needle biopsy with a 12cm long, disposable 16-gauge needle 1.8mm in diameter (Vitesse through 1cm skin incision in the depth of 1.2-1.6cm of parenchyma. Fifteen minutes after the biopsy, macroscopic injures of the parenchyma of all the boar testes were not detected in the ultrasound image. Twenty one days after biopsy, the hyperechogenic line 0.1-0.2cm in diameter was seen in the testes parenchyma of six boars in the depth of 1.2-1.6cm. The biopsy of boar testes did not influence the quality of boars ejaculate. The ultrasonographic examination of boar testicles before the biopsy reduced possibilities to traumatize large blood vessels of the testes. A perfect boar testicular biopsy was easy to perform using ultrasonographic examination in the pigsty conditions.

  9. Comparison of diagnostic quality of kidney biopsy obtained using 16g and 18g needles in patients with diffuse renal disease

    Directory of Open Access Journals (Sweden)

    Komal Arora

    2012-01-01

    Full Text Available To determine the diagnostic quality and complication rates of 16G and 18G needles in biopsy of the kidney, we performed renal biopsy using a biopsy gun under ultrasound guidance in 50 patients who were prospectively and evenly assigned to one of the two needle biopsy methods from April 2007 until May 2008. Two cores of renal biopsy specimen were obtained in each case and subjected to histopathological and immunoflourescence (IF examination. Pain associated with the procedure was assessed using a visual analog scale. The number of glomeruli retrieved using the 16G needle ranged from 0 to 30 (mean 9.42 ± 5.5 and those retrieved using 18G needle ranged from 0 to 19 (mean 7.72 ± 4.4, P <0.05. The quality of biopsy was poorer with 18G needle as compared with 16G needles because of a higher amount of fragmentation and crushing artifact. There was no difference in the compli-cation rates between the two needles (2% each. The 16G needle was associated with significantly more pain than the 18G needle. We conclude that our study demonstrates the benefit of the larger 16G needle in providing more tissue and glomeruli, which is more diagnostically useful. However, the use of 16G needle was associated with significantly more pain than the 18G needle, and may be a better compromise for diagnostic usefulness and patient acceptability.

  10. Essential elements of quality control.

    Science.gov (United States)

    Boylan, J C

    1983-11-01

    The components of quality control in the pharmaceutical industry are discussed as they apply to hospital pharmacy admixture services. The pharmaceutical industry complies with the FDA's Current Good Manufacturing Practices, which require manufacturers to have written procedures for ensuring sterility and nonpyrogenicity of injectable products. Because FDA specifies only what outcome measures must be assessed (rather than specific means of assessment), pharmaceutical companies have developed a multiplicity of quality-control systems. However, each system consists of a master formula (quantitative listing of all ingredients), master manufacturing instructions (the recipe for each product), master packaging instructions, and batch records. Documents used by quality control personnel include the specifications (identification, tests, and limits for products), test methods, and sampling procedures. Hospitals should have similar quality-control programs. These programs should systematically prevent or identify and correct deficiencies, measure overall quality, and provide information for managers. Hospital pharmacists whose departments do not have comprehensive programs should consult colleagues who have developed such procedures. Techniques used in industry should be applied when possible. To protect the integrity of manufacturers' drug products during compounding in hospitals, every hospital admixture service must have its own quality-control system. PMID:6650523

  11. 10 CFR 26.137 - Quality assurance and quality control.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Quality assurance and quality control. 26.137 Section 26....137 Quality assurance and quality control. (a) Quality assurance program. Each licensee testing facility shall have a quality assurance program that encompasses all aspects of the testing...

  12. Frontiers in statistical quality control

    CERN Document Server

    Wilrich, Peter-Theodor

    2001-01-01

    The book is a collection of papers presented at the 5th International Workshop on Intelligent Statistical Quality Control in Würzburg, Germany. Contributions deal with methodology and successful industrial applications. They can be grouped in four catagories: Sampling Inspection, Statistical Process Control, Data Analysis and Process Capability Studies and Experimental Design.

  13. Quality assurance and statistical control

    DEFF Research Database (Denmark)

    Heydorn, K.

    1991-01-01

    In scientific research laboratories it is rarely possible to use quality assurance schemes, developed for large-scale analysis. Instead methods have been developed to control the quality of modest numbers of analytical results by relying on statistical control: Analysis of precision serves...... through the origo. Calibration control is an essential link in the traceability of results. Only one or two samples of pure solid or aqueous standards with accurately known content need to be analyzed. Verification is carried out by analyzing certified reference materials from BCR, NIST, or others...

  14. [Color Doppler controlled needle biopsy in diagnosis of soft tissue and bone tumors].

    Science.gov (United States)

    Schulte, M; Heymer, B; Sarkar, M R; Negri, G; von Baer, A; Hartwig, E

    1998-10-01

    In a prospective study we investigated 168 patients with musculoskeletal tumors, including 71 sarcomas, by core needle biopsy using the high-speed device Autovac. Monitoring with colour-coded duplex sonography allowed a well-aimed puncture of smaller or deeply localized lesions and also permitted the discrimination of necrotic and viable parts of the tumor. Adequate material for histologic diagnosis including grading and determination of tumor subtype was obtained from soft tissue sarcomas, soft tissue metastases, malignant lymphomas, plasmacytomas, and osteolytic skeletal secondaries. In contrast, in benign soft tissue and bone tumors the diagnosis could be established in only 66% of cases. Although skeletal sarcomas were identified as malignant mesenchymal lesions, a complete histologic classification of tumor subtype frequently was not possible due to an insufficient tissue specimen. With an accuracy of 97% for the diagnosis of malignancy and of 94% for the diagnosis of soft tissue sarcoma the results of core needle biopsies were comparable to those of incisional biopsies, the reference standard in the diagnosis of musculoskeletal tumors. Regarding the known disadvantages and the oncological risks of incisional biopsies, needle biopsy should replace the open procedure as the primary means of diagnosis in soft tissue and osteolytic bone tumors. PMID:9833186

  15. Post-mortem tissue biopsies obtained at minimally invasive autopsy: an RNA-quality analysis.

    Directory of Open Access Journals (Sweden)

    Anita van der Linden

    Full Text Available Bereaved relatives often refuse to give consent for post-mortem investigation of deceased cancer patients, mainly because of the mutilation due to conventional autopsy (CA. Minimally invasive autopsy (MIA may be a more acceptable alternative and, if implemented in clinical practice, creates an opportunity to more often obtain post-mortem tissue samples of (recurred primary tumors and metastases for molecular research. As a measure for tissue quality for molecular studies, we hereby present a feasibility study, comparing the RNA quality of MIA and CA samples, and fresh frozen samples as reference.Tissue samples of heart, liver and kidney were prospectively collected from 24 MIAs followed by CA, and compared to corresponding archival fresh frozen tissue. After RNA isolation and RT-qPCR, RNA integrity numbers (RIN and GAPDH expression (six amplicon sizes ranging from 71 to 530 base pairs were measured. RIN values and GAPDH Cq values were analyzed and compared between all sample groups and post-mortem intervals (PMI.RIN values in MIA samples were significantly higher than those in CA samples. GAPDH was expressed significantly higher in MIA samples than in CA samples and 530 bp PCR products could be measured in all cases. GAPDH expression was significantly lower in samples with PMI >15 hours. As expected, the samples of the fresh frozen reference standard performed best in all analyses.MIA samples showed better RNA quality than CA samples, probably due to shorter PMI. Both had lower RNA quality and expression levels than fresh frozen tissue, however, remaining GAPDH RNA was still sufficiently intact. Therefore, other highly expressed genes are most likely also detectable. Gene array analysis should be performed to gain insight into the quality of entire post-mortem genomes. Reducing PMI will further improve the feasibility of demanding molecular research on post-mortem tissues, this is most likely more feasible with MIA than CA.

  16. Quality control of imaging devices

    International Nuclear Information System (INIS)

    Quality assurance in nuclear medicine refers collectively to all aspects of a nuclear medicine service. It would include patient scheduling, radiopharmaceutical preparation and dispensing, radiation protection of patients, staff and general public, preventive maintenance and the care of instruments, methodology, data interpretation and records keeping, and many other small things which contribute directly or indirectly to the overall quality of a nuclear medicine service in a hospital. Quality Control, on the other hand, refers to a signal component of the system and is usually applied in relation to a specific instrument and its performance

  17. Radiation measurements and quality control

    International Nuclear Information System (INIS)

    The association between radiation measurements and quality control is established for radiation sterilization of medical products and food irradiation. Good quality control implies accurate radiation dosimetry and a discussion of the factors which can affect the accuracy of in-plant dosimetry is presented. It is argued that if systematic errors are to be avoided in in-plant dosimetry the plant operators will have to spend more time and effort in developing the skills associated with the accurate use of radiation dosemeter systems. The aims and merits of an international intercomparison programme recently set up by the IAEA are discussed. The benefits of accurate in-plant dosimetry for the operator, approving authority and purchaser are balanced against the extra dosimetric efforts required for good quality control. (author)

  18. Regional distribution and alterations of lectin binding to colorectal mucin in mucosal biopsies from controls and subjects with inflammatory bowel diseases.

    OpenAIRE

    Jacobs, L R; Huber, P W

    1985-01-01

    Glycoconjugate composition of colorectal goblet cell mucin was characterized according to the anatomical distribution of lectin-binding sites in mucosal biopsies from 35 control subjects and 55 patients with inflammatory bowel disease. 24 of the controls had mucosal inflammation on biopsy, without clinical evidence of inflammatory bowel disease. These inflamed controls showed a similar rate of presence of lectin-binding sites as the normal noninflamed group. In the controls, the frequency of ...

  19. Frontiers in statistical quality control

    CERN Document Server

    Wilrich, Peter-Theodor

    1997-01-01

    Like the preceding volumes, and met with a lively response, the present volume is collecting contributions stressed on methodology or successful industrial applications. The papers are classified under four main headings: sampling inspection, process quality control, data analysis and process capability studies and finally experimental design.

  20. Randomized controlled trial of antibiotic prophylaxis regimens for transrectai ultrasound-guided prostate biopsy

    Institute of Scientific and Technical Information of China (English)

    CHAN Eddie Shu-yin; LO Ka-lun; NG Chi-fai; HOU See-ming; YIP Sidney Kam-hung

    2012-01-01

    Background A prior study showed significant antibioti resistance to quinotone in our poputation.In this study we aimed to evaluate and compare the efficacy of a single versus a combined prophylactic antibiotic regimen before transrectal ultrasound-guided prostate biopsy(TRUGPB).Methods A prospective randomized study was conducted at a university hospital.Patients undergoing TRUGPB were randomized into an amoicillin-clavulanate alone(1mg;one dose before and two doses after biopsy)or an amoxicllin-clavulanate+ciprofloxacin group(250mg;one dose before and two doses after biopsy).Patients were surveyed for infection symptoms by phine on days 3 and 30 after TRUGPB.We defined an infective complication as the iccurrence of symptoms including fever,chills or rigor within 30 days after prostate biopsy,requiring medical treatment or hospitalization,aided by a tertiory-wide etectronic medical record system.Results Between November 2007 and July 2009,367 patients were randomized to either amoxicillin-clavulanate alone or amoxicillin-caavulanate+ciprofloxacin group.The infection rates after TRUGPB were 3.9%in the former group(7 out of 179 patoents)versus 0.53%(1 out of 188 patients)in the latter.Sixty-three percent(5/8)of patients with infective complications needed hospitalization.There was no intensive care unit admission or mortality during the study period.Conclusions Combining prophylactic antibiotics with amoxicllin-clavulanate+soprofloxacin significantly reduced the in cidence of infective complications after TRUGPB.We recommended a combination regimen,especially in centre with high incidence of post-TRUGPB infection.

  1. Control of quality in mammography

    International Nuclear Information System (INIS)

    The present protocol of quality control/quality assurance in mammography is the result of the work of two regional projects realised in Latin America within the frame of ARCAL with the support of the IAEA. The first is ARCAL LV (RLA/6/043) project on quality assurance/quality control in mammography studies which analysed the present situation of the mammography in the member countries of the project which include: Bolivia, Colombia, Costa Rica, Cuba, El Salvador, Guatemala, Nicaragua, Panama, Paraguay, Peru, Dominican Republic and Republic of Venezuela and the second is ARCAL XLIX (RLA/9/035) project, whose members were Brazil, Colombia, Cuba, Chile, Mexico, and Peru, worked the application of Basic Safety Standards for the protection against ionising radiation with the aim to improve radiation protection in X-ray diagnosis medical practices through the implementation of the Basic Safety Standards (BSS) related to x-ray diagnosis in selected hospitals located in each country involved in the project. The work of both projects had been consolidated and harmonized in the present publication

  2. CRANE WHEELS PRODUCTION QUALITY CONTROL

    OpenAIRE

    OTTO GRIGOROV; SERHY GUBSKIY; ANTON OKUN

    2014-01-01

    Quality control of crane wheels is an important part for support of crane mechanisms permanent operation. Normal functioning of logistics systems requires preventing of crane downtimes and delays. The research results of the impact of the crane wheels (710 mm diameter, 65 steel) surface hardness on coercivity indicators are presented in this paper. Obtained research results of dependence between the coercivity indicators and the crane wheels rolling surface hardness for their use in practice ...

  3. Evaluation of Histopathological Changes in Control Biopsies Which Taken 48 Sessions after NBUVB Phototherapy for Early-Stage Mycosis Fungoides

    Directory of Open Access Journals (Sweden)

    Ebru Zemheri

    2012-01-01

    Full Text Available Background. There are not many studies investigating histomorphological changes in 48 sessions in patients with early-stage MF after narrowband UVB (NBUVB treatment. Our purpose is to evaluate histological features of phototherapy after 48 sessions and determine which parameters are more reliable for controlling skin biopsies. Methods. Biopsies of 32 patients with early stage of MF, who were treated with NBUVB phototherapy, were histologically evaluated before and after the treatments, including epidermotropism, stratum corneum, epidermal thickness, dermal infiltration, papillary dermal fibrosis, vascular alterations, and other dermal changes. We discuss the histomorphological effects of NBUVB phototherapy on skin biopsies by comparing the responders with nonresponders, with before and after the treatment. Results. 9 patients (28% did not give any response to treatment. Alleviation in epidermotropism, increases in parakeratosis and normal keratosis, perivascular infiltration, and melanophages, decrease in the lichenoid/patchy lichenoid infiltration pattern after the treatment was statistically significant. Comparing by response, normalization of stratum corneum and epidermis, orthohyperkeratosis, decrease in linearly arranged cells, the lichenoid/patchy lichenoid infiltration, the loss of inflammation were statistically significant in responders group. Conclusion. We detected a significant decrease in linearly arranged cells after phototherapy, indicating that it is an “important diagnostic parameter" in evaluation of therapeutic response.

  4. Radiation measurements and quality control

    International Nuclear Information System (INIS)

    Accurate measurements are essential to research leading to a successful radiation process and to the commissioning of the process and the facility. On the other hand, once the process is in production, the importance to quality control of measuring radiation quantities (i.e., absorbed dose, dose rate, dose distribution) rather than various other parameters of the process (i.e. conveyor speed, dwell time, radiation field characteristics, product dimensions) is not clearly established. When the safety of the product is determined by the magnitude of the administered dose, as in radiation sterilization, waste control, or food preservation, accuracy and precision of the measurement of the effective dose are vital. Since physical dose measurements are usually simpler, more reliable and reproducible than biological testing of the product, there is a trend toward using standardized dosimetry for quality control of some processes. In many industrial products, however, such as vulcanized rubber, textiles, plastics, coatings, films, wire and cable, the effective dose can be controlled satisfactorily by controlling process variables or by product testing itself. In the measurement of radiation dose profiles by dosimetry, it is necessary to have suitable dose meter calibrations, to account for sources of error and imprecision, and to use correct statistical procedures in specifying dwell times or conveyor speeds and source and product parameters to achieve minimum and maximum doses within specifications. (author)

  5. Synovial biopsy

    Science.gov (United States)

    ... small incision. After anesthesia, an instrument called a trocar is inserted into the joint space. This tool ... area. A biopsy grasper is inserted through the trocar and turned to cut out a tissue segment. ...

  6. Testicular biopsy

    Science.gov (United States)

    Biopsy - testicle ... or at a hospital. The skin over the testicle is cleaned with a germ-killing (antiseptic) medicine. ... through the skin. A small piece of the testicle tissue is removed. The opening in the testicle ...

  7. Renal Tumor Biopsy Technique

    Institute of Scientific and Technical Information of China (English)

    Lei Zhang; Xue-Song Li; Li-Qun Zhou

    2016-01-01

    Objective:To review hot issues and future direction of renal tumor biopsy (RTB) technique.Data Sources:The literature concerning or including RTB technique in English was collected from PubMed published from 1990 to 2015.Study Selection:We included all the relevant articles on RTB technique in English,with no limitation of study design.Results:Computed tomography and ultrasound were usually used for guiding RTB with respective advantages.Core biopsy is more preferred over fine needle aspiration because of superior accuracy.A minimum of two good-quality cores for a single renal tumor is generally accepted.The use of coaxial guide is recommended.For biopsy location,sampling different regions including central and peripheral biopsies are recommended.Conclusion:In spite of some limitations,RTB technique is relatively mature to help optimize the treatment of renal tumors.

  8. Quality control programme for radiotherapy

    International Nuclear Information System (INIS)

    A 3 years pilot programme started in January 2000 with 33 philanthropic cancer institutions that provides medical services to 60% of the patients from the national social security system. Brazil has today 161 radiotherapy services (144 operating with megavoltage equipment). These 33 institutions are distributed over 19 Brazilian states. The aim of this programme is: To create conditions to allow the participants to apply the radiotherapy with quality and efficacy; To promote up dating courses for the physicians, physicists and technicians of these 33 Institutions. With the following objectives: To recommend dosimetric and radiological protection procedures in order to guarantee the tumor prescribed dose and safe working conditions; To help in establishing and implementing these procedures. The main activities are: local quality control evaluations, postal TLD audits in reference conditions, postal TLD audits in off axis conditions and training. The local quality control program has already evaluated 22 institutions with 43 machines (25 Co-60 and 18 linear accelerators). In these visits we perform dosimetric, electrical, mechanical and safety tests. As foreseen, we found more problems among the old Co-60 machines i.e., field flatness, size, symmetry and relative output factors; lasers positioning system alignment; optical distance indicator; radiation and light field coincidence; optical and mechanical distance indicators agreement, than among the linear accelerators i.e., field flatness and size; lasers positioning system alignment; tray interlocking and wedge filter factors

  9. Quality control of pesticide products

    International Nuclear Information System (INIS)

    In light of an established need for more efficient analytical procedures, this publication, which documents the findings of an IAEA coordinated research project (CRP) on “Quality Control of Pesticide Products”, simplifies the existing protocol for pesticide analysis while simultaneously upholding existing standards of quality. This publication includes both a report on the development work done in the CRP and a training manual for use by pesticide analysis laboratories. Based on peer reviewed and internationally recognized methods published by the Association of Analytical Communities (AOAC) and the Collaborative International Pesticides Analytical Council (CIPAC), this report provides laboratories with versatile tools to enhance the analysis of pesticide chemicals and to extend the scope of available analytical repertoires. Adoption of the proposed analytical methodologies promises to reduce laboratories’ use of solvents and the time spent on reconfiguration and set-up of analytical equipment

  10. Family Control and Earnings Quality

    Directory of Open Access Journals (Sweden)

    Carolina Bona Sánchez

    2007-06-01

    Full Text Available El trabajo analiza la relación entre el control familiar y la calidad de la información contable en un contexto en el que el tradicional conflicto de agencia entre directivos y accionistas se desplaza a la divergencia de intereses entre accionistas controladores y minoritarios. Los resultados alcanzados muestran que, en comparación con las no familiares, las empresas de naturaleza familiar divulgan unos resultados de mayor calidad, tanto en términos de menores ajustes por devengo discrecionales como de mayor capacidad de los componentes actuales del resultado para predecir los cash flows futuros. Además, el aumento en los derechos de voto en manos de la familia controladora incrementa la calidad de los resultados contables. La evidencia obtenida se muestra consistente con la presencia de un efecto reputación/vinculación a largo plazo asociado a la empresa familiar. Adicionalmente, el trabajo refleja que a medida que disminuye la divergencia entre los derechos de voto y de cash flow en manos de la familia controladora, aumenta la calidad de la información contable.PALABRAS CLAVE: derechos de voto, divergencia, empresa familiar, calidad delresultado, reputación, beneficios privados.This work examines the relationship between family control and earnings quality in a context where the salient agency problem shifts away from the classical divergence between managers and shareholders to conflicts between the controlling owner and minority shareholders. The results reveal that, compared to non-family firms, family firms reveal higher earnings quality in terms of both lower discretionary accruals and greater predictability of future cash flows. They also show a positive relationship between the level of voting rights held by the controlling family and earnings quality. The evidence is consistent with the presence of a reputation/long-term involvement effect associated with the family firm. Moreover, the work reflects that, as the divergence

  11. 40 CFR 51.359 - Quality control.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 2 2010-07-01 2010-07-01 false Quality control. 51.359 Section 51.359....359 Quality control. Quality control measures shall insure that emission testing equipment is calibrated and maintained properly, and that inspection, calibration records, and control charts...

  12. Quality control in breast tomosynthesis

    Energy Technology Data Exchange (ETDEWEB)

    Jakubiak, R.R.; Messias, P.C.; Santos, M.F., E-mail: requi@utfpr.edu.br [Universidade Tecnologia Federal do Parana (UTFPR), Curitiba, PR (Brazil). Departamento Academico de Fisica; Urban, L.A.B.D., E-mail: lineiurban@hotmail.com [Diagnostico Avancado por Imagem, Curitiba, PR (Brazil)

    2015-07-01

    In Brazil, breast cancer is the most common and the leading cause of death among women, with estimated 57,000 new cases in 2014. The mammography (2D) plays an important role in the early detection of breast cancer, but in some cases can be difficult to detect malignant lesions due overlap of breast tissues. The Digital Breasts Tomosynthesis (DBT: 3D) reduces the effects of overlap, providing improved characterization of mammographic findings. However, the dose may double as compared with mammography. This study presents results of Contrast to Noise Ratio (CNR) and image quality evaluation on Siemens mammography equipment Mammomat Inspiration with tomosynthesis. The CNR was determined with Polymethylmethacrylate (PMMA) layers of 20 to 70 mm thick and an aluminum foils of 0,2 mm thickness and area of 10 mm². Image quality was assessed with the ACR Breast Simulator. In the evaluation of image quality, the detectability of fibers and masses was identical in 2D and 3D systems. Displaying fibers were 4,5 and 4 mass in both modes. In 2D mode were identified 3,5 microcalcifications groups, and 3D showed 3 groups. The Mean Glandular Dose (MGD) for the simulator in 2D mode was 1,17 mGy and 2,35 mGy for the 3D mode. The result reinforces the importance of quality control in the process of obtaining the images and obtained in accordance CNR values, ensuring image quality and compatible dose in 2D and 3D processes. (author)

  13. Quality control in breast tomosynthesis

    International Nuclear Information System (INIS)

    In Brazil, breast cancer is the most common and the leading cause of death among women, with estimated 57,000 new cases in 2014. The mammography (2D) plays an important role in the early detection of breast cancer, but in some cases can be difficult to detect malignant lesions due overlap of breast tissues. The Digital Breasts Tomosynthesis (DBT: 3D) reduces the effects of overlap, providing improved characterization of mammographic findings. However, the dose may double as compared with mammography. This study presents results of Contrast to Noise Ratio (CNR) and image quality evaluation on Siemens mammography equipment Mammomat Inspiration with tomosynthesis. The CNR was determined with Polymethylmethacrylate (PMMA) layers of 20 to 70 mm thick and an aluminum foils of 0,2 mm thickness and area of 10 mm². Image quality was assessed with the ACR Breast Simulator. In the evaluation of image quality, the detectability of fibers and masses was identical in 2D and 3D systems. Displaying fibers were 4,5 and 4 mass in both modes. In 2D mode were identified 3,5 microcalcifications groups, and 3D showed 3 groups. The Mean Glandular Dose (MGD) for the simulator in 2D mode was 1,17 mGy and 2,35 mGy for the 3D mode. The result reinforces the importance of quality control in the process of obtaining the images and obtained in accordance CNR values, ensuring image quality and compatible dose in 2D and 3D processes. (author)

  14. Quality control in breast tomosynthesis

    International Nuclear Information System (INIS)

    In Brazil breast cancer is the most common and the leading cause of death among women, with estimated 57,000 new cases in 2014. The mammography (2D) plays an important role in the early detection of breast cancer, but in some cases can be difficult to detect malignant lesions due overlap of breast tissues. The Breast Digital Tomosynthesis (BDT: 3D) reduces the effects of overlap, providing improved characterization of mammographic findings. However, the dose may double as compared to the mammography. This study presents results of Contrast Ratio Noise tests (CRN) and quality image on a Siemens mammography equipment Mammomat Inspiration with tomosynthesis. The CRN was determined with plates Polymethylmethacrylate (PMMA) of 20 to 70 mm thickness and an aluminum plate of 10 mm2 and 0.2 mm thickness. Image quality was assessed with the ACR Breast Simulator. In assessment of image quality, the detectability of fibers and masses was identical in 2D and 3D systems. Were visualized 4.5 fibers and 4 mass in both modes. In 2D mode groups have been identified 3.5 microcalcifications, and 3D were 3 groups. The Mean Glandular Dose for the simulator in 2D mode was 1.17 mGy and 2.35 mGy for the 3D mode. The result reinforces the importance of quality control in the process of obtaining the images and obtained in accordance CRN values, ensuring image quality and dose compatible in 2D and 3D processes

  15. Endomyocardial biopsy

    International Nuclear Information System (INIS)

    As the result of recent improvements in catheter design and pathologic interpretation, transvascular endomyocardial biopsy has become an important component in the invasive evaluation of patients with known or suspected primary myocardial dysfunction. Because significant controversy remains about the definition, frequency, natural history, and optimal treatment, of many of these myocardial disorders, however, use of the endomyocardial biopsy in the routine evaluation of patients with myocardial disease varies from center to center. This chapter focuses on the currently available techniques for endomyocardial histology appears most valuable, rather than on a precise listing of current indications for this procedure

  16. Internal quality control: best practice.

    Science.gov (United States)

    Kinns, Helen; Pitkin, Sarah; Housley, David; Freedman, Danielle B

    2013-12-01

    There is a wide variation in laboratory practice with regard to implementation and review of internal quality control (IQC). A poor approach can lead to a spectrum of scenarios from validation of incorrect patient results to over investigation of falsely rejected analytical runs. This article will provide a practical approach for the routine clinical biochemistry laboratory to introduce an efficient quality control system that will optimise error detection and reduce the rate of false rejection. Each stage of the IQC system is considered, from selection of IQC material to selection of IQC rules, and finally the appropriate action to follow when a rejection signal has been obtained. The main objective of IQC is to ensure day-to-day consistency of an analytical process and thus help to determine whether patient results are reliable enough to be released. The required quality and assay performance varies between analytes as does the definition of a clinically significant error. Unfortunately many laboratories currently decide what is clinically significant at the troubleshooting stage. Assay-specific IQC systems will reduce the number of inappropriate sample-run rejections compared with the blanket use of one IQC rule. In practice, only three or four different IQC rules are required for the whole of the routine biochemistry repertoire as assays are assigned into groups based on performance. The tools to categorise performance and assign IQC rules based on that performance are presented. Although significant investment of time and education is required prior to implementation, laboratories have shown that such systems achieve considerable reductions in cost and labour.

  17. Lymph node biopsy

    Science.gov (United States)

    Biopsy - lymph nodes; Open lymph node biopsy; Fine needle aspiration biopsy; Sentinel lymph node biopsy ... A lymph node biopsy is done in an operating room in a hospital. Or, it is done at an outpatient surgical center. The ...

  18. Ureteral retrograde brush biopsy

    Science.gov (United States)

    Biopsy - brush - urinary tract; Retrograde ureteral brush biopsy cytology; Cytology - ureteral retrograde brush biopsy ... to be biopsied is rubbed with the brush. Biopsy forceps may be used instead to collect a ...

  19. 14 CFR 21.139 - Quality control.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Quality control. 21.139 Section 21.139... PROCEDURES FOR PRODUCTS AND PARTS Production Certificates § 21.139 Quality control. The applicant must show that he has established and can maintain a quality control system for any product, for which...

  20. 33 CFR 385.21 - Quality control.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 3 2010-07-01 2010-07-01 false Quality control. 385.21 Section... Processes § 385.21 Quality control. (a) The Corps of Engineers and the non-Federal sponsor shall prepare a quality control plan, in accordance with applicable Corps of Engineers regulations, for each product...

  1. 7 CFR 930.44 - Quality control.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 8 2010-01-01 2010-01-01 false Quality control. 930.44 Section 930.44 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing Agreements... Control § 930.44 Quality control. (a) Quality standards. The Board may establish, with the approval of...

  2. 7 CFR 981.42 - Quality control.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 8 2010-01-01 2010-01-01 false Quality control. 981.42 Section 981.42 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing Agreements... Regulating Handling Quality Control § 981.42 Quality control. (a) Incoming. Except as provided in...

  3. Antibodies in the diagnosis of coeliac disease: a biopsy-controlled, international, multicentre study of 376 children with coeliac disease and 695 controls.

    Directory of Open Access Journals (Sweden)

    Johannes Wolf

    Full Text Available Diagnosis of coeliac disease (CD relies on a combination of clinical, genetic, serological and duodenal morphological findings. The ESPGHAN suggested that biopsy may not be necessary in all cases. New guidelines include omission of biopsy if the concentration of CD-specific antibodies exceeds 10 times the upper limit of normal (10 ULN and other criteria are met. We analysed the 10 ULN criterion and investigated multiple antibody-assays. Serum was collected from 1071 children with duodenal biopsy (376 CD patients, 695 disease-controls. IgA-antibodies to tissue transglutaminase (IgA-aTTG, IgG-antibodies to deamidated gliadin peptides (IgG-aDGL and IgA-endomysium antibodies (IgA-EMA were measured centrally. We considered 3 outcomes for antibody test procedures utilizing IgA-aTTG and/or IgG-aDGL: positive (≥10 ULN, recommend gluten-free diet, negative (90% and PPV/NPV >95%. These stringent conditions were met for appropriate antibody-procedures over a prevalence range of 9-57%. By combining IgG-aDGL with IgA-aTTG, one could do without assaying total IgA. The PPV of IgG-aDGL was estimated to be extremely high, although more studies are necessary to narrow down the LCB. The proportion of patients requiring a biopsy was <11%. The procedures were either equivalent or even better in children <2 years compared to older children. All 310 of the IgA-aTTG positive children were also IgA-EMA positive. Antibody-assays could render biopsies unnecessary in most children, if experienced paediatric gastroenterologists evaluate the case. This suggestion only applies to the kits used here and should be verified for other available assays. Confirming IgA-aTTG positivity (≥10 ULN by EMA-testing is unnecessary if performed on the same blood sample. Prospective studies are needed.

  4. Radiopharmaceutical quality control-Pragmatic approach

    International Nuclear Information System (INIS)

    The quality control must be considered in a practical manner. The radiopharmaceuticals are drugs. They must satisfy the quality assurance control. These products are then conform to Pharmacopeia. But sometimes the user must control some data especially radiochemical purity and pH value. On all the administered solutions four controls are compulsory: radionuclide identity, administered radioactivity, organoleptic character and pH

  5. Local Control Following Permanent Prostate Brachytherapy: Effect of High Biologically Effective Dose on Biopsy Results and Oncologic Outcomes

    International Nuclear Information System (INIS)

    Purpose: To determine factors that influence local control and systemic relapse in patients undergoing permanent prostate brachytherapy (PPB). Methods and Materials: A total of 584 patients receiving PPB alone or PPB with external beam radiation therapy (19.5%) agreed to undergo prostate biopsy (PB) at 2 years postimplantion and yearly if results were positive or if the prostate-specific antigen (PSA) level increased. Short-term hormone therapy was used with 280 (47.9%) patients. Radiation doses were converted to biologically effective doses (BED) (using α/β = 2). Comparisons were made by chi-square analysis and linear regression. Survival was determined by the Kaplan-Meier method. Results: The median PSA concentration was 7.1 ng/ml, and the median follow-up period was 7.1 years. PB results were positive for 48/584 (8.2%) patients. Positive biopsy results by BED group were as follows: 22/121 (18.2%) patients received a BED of ≤150 Gy; 15/244 (6.1%) patients received >150 to 200 Gy; and 6/193 (3.1%; p 200 Gy. Significant associations of positive PB results by risk group were low-risk group BED (p = 0.019), intermediate-risk group hormone therapy (p = 0.011) and BED (p = 0.040), and high-risk group BED (p = 0.004). Biochemical freedom from failure rate at 7 years was 82.7%. Biochemical freedom from failure rate by PB result was 84.7% for negative results vs. 59.2% for positive results (p 200 Gy with an α/β ratio of 2 yields 96.9% local control rate. Failure to establish local control impacts survival.

  6. Health-related Quality of Life in Vacuum-Assisted Breast Biopsy: short-term effects, long-term effects and predictors

    Directory of Open Access Journals (Sweden)

    Zografos George C

    2010-01-01

    Full Text Available Abstract Background The impact of Vacuum-assisted breast biopsy (VABB, 11-Gauge upon Health-related Quality of Life (HRQoL remains an open field. This study aims to: i assess short-term (4 days after VABB responses in terms of HRQoL after VABB, ii evaluate long-term (18 months after VABB responses, if any, and iii examine whether these responses are modified by a variety of possible predictors (anthropometric, sociodemographic, lifestyle habits, breast-related parameters, reproductive history, VABB-related features and complications, seasonality. Methods This study included 102 eligible patients undergoing VABB and having benign lesions. A variable number of cores (24-96 cores has been excised. HRQoL was assessed by EQ-5D and SF-36® questionnaires: i in the morning of the VABB procedure day (baseline measurement, ii four days after VABB (early post-biopsy measurement and iii 18 months after VABB (late post-biopsy measurement. Statistical analysis comprised two steps: i. evaluation of differences in EQ-5D/SF-36 dimensions and calculated scores (baseline versus early post-biopsy measurement and baseline versus late post-biopsy measurement and ii. assessment of predictors through multivariate linear, logistic, ordinal logistic regression, as appropriate. Results At baseline patients presented with considerable anxiety (EQ-5D anxiety/depression dimension, EQ-5D TTO/VAS indices, SF-36 Mental Health dimension. At the early post-biopsy measurement women exhibited deterioration in Usual Activities (EQ-5D and Role Functioning-Physical dimensions. At the late measurement women exhibited pain (EQ-5D pain/discomfort and SF-36 Bodily Pain, deterioration in Physical Functioning (SF-36 PF and overall SF-36 Physical Component Scale (PCS. Mastalgia, older age and lower income emerged as significant predictors for baseline anxiety, whereas seasonality modified early activities-related responses. Pain seemed idiosyncratic. Conclusions The HRQoL profile of

  7. MAIN PROBLEMS OF CONTROLLING OF THE QUALITY

    Directory of Open Access Journals (Sweden)

    Orlov A. I.

    2015-09-01

    Full Text Available Controlling of statistical methods to ensure product quality is the special case of controlling organizational and economic methods of management. Today, controlling in the practice of management of Russian companies is understood as "the system of information-analytical and methodological support to achieve their goals." The controller is developing a decision-making rules, the head takes decisions on the basis of these rules. We proved the concept of "controlling of methods". Innovation in management is based, in particular, on the use of new adequate organizational-economic (as well as economicmathematical and statistical methods. Controlling in this area - is the development and application procedures of compliance management used and newly developed (implemented organizationaleconomic methods for the task. Thus, the methodology for controlling is of great practical value in any field in which the actions (operations must be carried out in accordance with certain rules (regulations, standards, guidelines, as in any such area in which we need to use development and application procedures of compliance management used and the newly established (implemented rules for solution of tasks assigned to the organization. In this article, we select a area of controlling as controlling quality, and we discuss its main issues. This is about controlling of organizational-economic methods to ensure product quality, especially about the statistical methods based on probability theory and mathematical statistics. We consider the analysis and synthesis of plans of statistical quality control, optimization options plans of statistical control, truncated plans. Are discussed the differences control plans provider and the consumer, the allocation of units formless (liquid, gas products, the selection of a random sample of the statistical quality control of products, lower estimate of the required sample size. It is established, that is not always necessary

  8. Nasal mucosal biopsy

    Science.gov (United States)

    Biopsy - nasal mucosa; Nose biopsy ... to fast for a few hours before the biopsy. ... Nasal mucosal biopsy is usually done when abnormal tissue is seen during examination of the nose. It may also be done ...

  9. Bone lesion biopsy

    Science.gov (United States)

    Bone biopsy; Biopsy - bone ... is sent to a lab for examination. Bone biopsy may also be done under general anesthesia to ... remove the bone can be done if the biopsy exam shows that there is an abnormal growth ...

  10. Biopsy - biliary tract

    Science.gov (United States)

    Cytology analysis - biliary tract; Biliary tract biopsy ... A sample for a biliary tract biopsy can be obtained in different ways. A needle biopsy can be done if you have a well-defined tumor. The biopsy site ...

  11. Establishment for quality control of experimental animal

    International Nuclear Information System (INIS)

    Until now, because we have imported experimental animal from foreign experimental animal corporation, we could have saved money by establishing the quality control of animal in barrier system. In order to improve the quality of animal experiment and efficiency of biomedical study, it is indispensable to control many factors that effect in the experiment. Therefore, it is essential to organize the system of laboratory animal care for enhancing reliability and revivability of experimental results. The purpose of the present investigation was to establish the quality control system of experimental animals that we can provide good quality animals according to the experimental condition of each investigator although the exact quality control system to estimate the infection of bacteria and virus easily remains ill-defined yet. Accordingly, we established the useful quality control system for microbiologic monitoring and environmental monitoring to protect experimental animal from harmful bacteria and virus

  12. Establishment for quality control of experimental animal

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Tae Hwan; Kim, Soo Kwan; Kim, Tae Kyoung

    1999-06-01

    Until now, because we have imported experimental animal from foreign experimental animal corporation, we could have saved money by establishing the quality control of animal in barrier system. In order to improve the quality of animal experiment and efficiency of biomedical study, it is indispensable to control many factors that effect in the experiment. Therefore, it is essential to organize the system of laboratory animal care for enhancing reliability and revivability of experimental results. The purpose of the present investigation was to establish the quality control system of experimental animals that we can provide good quality animals according to the experimental condition of each investigator although the exact quality control system to estimate the infection of bacteria and virus easily remains ill-defined yet. Accordingly, we established the useful quality control system for microbiologic monitoring and environmental monitoring to protect experimental animal from harmful bacteria and virus.

  13. Quality Control in Production Processes

    Directory of Open Access Journals (Sweden)

    Prístavka Miroslav

    2016-09-01

    Full Text Available The tools for quality management are used for quality improvement throughout the whole Europe and developed countries. Simple statistics are considered one of the most basic methods. The goal was to apply the simple statistical methods to practice and to solve problems by using them. Selected methods are used for processing the list of internal discrepancies within the organization, and for identification of the root cause of the problem and its appropriate solution. Seven basic quality tools are simple graphical tools, but very effective in solving problems related to quality. They are called essential because they are suitable for people with at least basic knowledge in statistics; therefore, they can be used to solve the vast majority of problems.

  14. Quality control of mammographic systems

    International Nuclear Information System (INIS)

    High quality in mammography is a difficult objective to achieve, that is the reason for what efforts are made in order to improve equipment, to offer good combinations screen-film, and professional staff dedicated to this technique

  15. Quality control education in the community college

    Science.gov (United States)

    Greene, J. Griffen; Wilson, Steve

    1966-01-01

    This paper describes the Quality Control Program at Daytona Beach Junior College, including course descriptions. The program in quality control required communication between the college and the American Society for Quality Control (ASQC). The college has machinery established for certification of the learning process, and the society has the source of teachers who are competent in the technical field and who are the employers of the educational products. The associate degree for quality control does not have a fixed program, which can serve all needs, any more than all engineering degrees have identical programs. The main ideas which would be common to all quality control programs are the concept of economic control of a repetitive process and the concept of developing individual potentialities into individuals who are needed and productive.

  16. 30 CFR 74.6 - Quality control.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Quality control. 74.6 Section 74.6 Mineral... of the CMDPSU will be maintained in production through adequate quality control procedures, MSHA and... DUST SAMPLING DEVICES Approval Requirements for Coal Mine Dust Personal Sampler Unit § 74.6...

  17. 7 CFR 981.442 - Quality control.

    Science.gov (United States)

    2010-01-01

    ..., see the List of CFR Sections Affected, which appears in the Finding Aids section of the printed volume... 7 Agriculture 8 2010-01-01 2010-01-01 false Quality control. 981.442 Section 981.442 Agriculture... Administrative Rules and Regulations § 981.442 Quality control. (a) Incoming. Pursuant to § 981.42(a),...

  18. Quality control within the windmill branch

    International Nuclear Information System (INIS)

    The aim of the project was to improve the quality of Danish-produced wind turbines by initiating quality control and working out general technical guidelines compatible with European standards so that these products can be authorized internationally. Guidelines for blade production, and purchase of gear boxes are presented in addition to an explanation of the concept of quality control. Administrational procedures in relation to authorization are also explained. (AB)

  19. Parotid gland biopsy compared with labial biopsy in the diagnosis of patients with primary Sjogren's syndrome

    NARCIS (Netherlands)

    Pijpe, J.; Kalk, W. W. I.; van der Wal, J. E.; Vissink, A.; Kluin, Ph. M.; Roodenburg, J. L. N.; Bootsma, H.; Kallenberg, C. G. M.; Spijkervet, F. K. L.

    2007-01-01

    Objective. To assess the value of the parotid biopsy as a diagnostic tool for primary Sjogren's syndrome ( pSS), and to compare the parotid biopsy and the labial biopsy with regard to diagnostic value and biopsy-related morbidity. Methods. In 15 consecutive patients with pSS and 20 controls, the par

  20. Quality-control analytical methods: continuous quality improvement.

    Science.gov (United States)

    Venti, Eden M

    2006-01-01

    It is vital that all compounding pharmacies have a continuous quality improvement program in place by way of standard operating procedures to assure that patients receive high-quality preparations. The program should take into consideration any federal and state regulatory requirements, as well as professional association expectations. Quality control measurements and regular review of those measurements are the foundations of a good quality plan. All pharmacy personnel should be aware of the importance of reporting potential internal quality concerns or problems and should be encouraged to do so without fear of repercussions. Ideally, an error-free compounding pracitice would be the goal. Since this is not practical, quality issues should not be viewed as problems, but as opportunities to improve compounding practices by correcting, before they become pervasive, the processes used in the preparation of prescriptions. PMID:23974418

  1. Quality control in the radioactive waste management

    International Nuclear Information System (INIS)

    Radioactive waste management as in industrial activities must mantain in all steps a quality control programme. This control extended from materials acquisition, for waste treatment, to the package deposition is one of the most important activities because it aims to observe the waste acceptance criteria in repositories and allows to guarantee the security of the nuclear facilities. In this work basic knowledges about quality control in waste management and some examples of adopted procedures in other countries are given. (author)

  2. Sensometrics for Food Quality Control

    OpenAIRE

    Brockhoff, Per B.

    2011-01-01

    The industrial development of innovative and succesful food items and the measuring of food quality in general is difficult without actually letting human beings evaluate the products using their senses at some point in the process. The use of humans as measurement instruments calls for special attention in the modelling and data analysis phase. In this paper the focus is on sensometrics – the „metric“ side of the sensory science field. The sensometrics field is introduced and related to the ...

  3. Control by quality: proposition of a typology.

    Science.gov (United States)

    Pujo, P; Pillet, M

    The application of Quality tools and methods in industrial management has always had a fundamental impact on the control of production. It influences the behavior of the actors concerned, while introducing the necessary notions and formalizations, especially for production systems with little or no automation, which constitute a large part of the industrial activity. Several quality approaches are applied in the workshop and are implemented at the level of the control. In this paper, the authors present a typology of the various approaches that have successively influenced control, such as statistical process control, quality assurance, and continuous improvement. First the authors present a parallel between production control and quality organizational structure. They note the duality between control, which is aimed at increasing productivity, and quality, which aims to satisfy the needs of the customer. They also note the hierarchical organizational structure of these two systems of management with, at each level, the notion of a feedback loop. This notion is fundamental to any kind of decision making. The paper is organized around the operational, tactical, and strategic levels, by describing for each level the main methods and tools for control by quality. The overview of these tools and methods starts at the operational level, with the Statistical Process Control, the Taguchi technique, and the "six sigma" approach. On the tactical level, we find a quality system approach, with a documented description of the procedures introduced in the firm. The management system can refer here to Quality Assurance, Total Productive Maintenance, or Management by Total Quality. The formalization through procedures of the rules of decision governing the process control enhances the validity of these rules. This leads to the enhancement of their reliability and to their consolidation. All this counterbalances the human, intrinsically fluctuating, behavior of the control

  4. Sensometrics for Food Quality Control

    DEFF Research Database (Denmark)

    Brockhoff, Per B.

    2011-01-01

    attention in the modelling and data analysis phase. In this paper the focus is on sensometrics – the „metric“ side of the sensory science field. The sensometrics field is introduced and related to the fields of statistics, chemometrics and psychometrics. Some of the most commonly used sensory testing......The industrial development of innovative and succesful food items and the measuring of food quality in general is difficult without actually letting human beings evaluate the products using their senses at some point in the process. The use of humans as measurement instruments calls for special...

  5. Quality assurance and quality control in the radon measurement industry

    International Nuclear Information System (INIS)

    Since the release of survey results by the consumer advocacy group BUYERS-UP, QA/QC has bee the buzz word among everyone involved with Radon/Radon Decay Product measurement. This paper presents a discussion in generality of the roles of Quality Assurance and Quality Control in the Radon Measurement Industry, the strengths and weaknesses of QA/QC in radon measurement and the significance of research in QA/QC for radon measurement

  6. Control mechanisms for assuring better IS quality:

    OpenAIRE

    Pivka, Marjan

    1998-01-01

    The software domain is faced with a number of quality assurance and process improvement models. Business managers are under pressure from many different kinds of assessments for their operations, products and services. Accounting departments are audited by financial auditors. What about information systems? Do we have a universal model on how to achieve required IS quality? This paper deals with the definition of IS quality and the influence of different control mechanisms on IS. The results ...

  7. PET/CT instrumentation: Quality assurance and quality control

    International Nuclear Information System (INIS)

    Improvement in quality assurance in Nuclear Medicine and in particular, in quality control of related equipment is a major field of interest of the International Atomic Energy Agency (IAEA). Several technical documents pertaining to scintigraphic imaging have been published and are being used as reference manuals by many professionals in the field (e.g., TECDOC 317, TECDOC 602, STI/PUB 1141). Positron emission tomography (PET) scanners and related performance assessment and quality control were not included in the previously published documents, as PET has been mainly a research tool, with limited worldwide distribution until the 90's. The tremendous role played presently by PET and PET/CT in whole-body oncology for lesion detection, staging and follow-up as well as the increasing role for PET in cardiology and neurology, associated with increasing reimbursement of multiple PET indications have prompted the need for updated guidelines specific to PET and PET/CT in terms of acceptance testing as well as quality control and assurance. The aim of this work is to present an overview of acceptance testing and quality assurance and control for PET and PET/CT

  8. A quality control manual for oral radiology

    International Nuclear Information System (INIS)

    A quality control manual for oral radiology is showed. The X-ray equipment used for this activity is described, such as the X-ray tube, collimator. The high tension in X-ray tube, the spectra, the quality and the quantity of radiation and the X-ray intensity are also analysed. (C.G.C.)

  9. Quality or Control? Management in Higher Education

    Science.gov (United States)

    Milliken, John; Colohan, Gerry

    2004-01-01

    Over the past fifteen years the rationale, organisational infrastructure and delivery of social policy in Britain have undergone radical transformation. Whereas efficiency was the key word of the 1980s, quality was the touchstone of the 1990s and quality control with accountability has become the management philosophy of the new millennium.…

  10. Net analyte signal based statistical quality control

    NARCIS (Netherlands)

    Skibsted, E.T.S.; Boelens, H.F.M.; Westerhuis, J.A.; Smilde, A.K.; Broad, N.W.; Rees, D.R.; Witte, D.T.

    2005-01-01

    Net analyte signal statistical quality control (NAS-SQC) is a new methodology to perform multivariate product quality monitoring based on the net analyte signal approach. The main advantage of NAS-SQC is that the systematic variation in the product due to the analyte (or property) of interest is sep

  11. Quality control of seasonal influenza vaccines.

    Science.gov (United States)

    Mandušić Nazor, Tamara; Pipić Kosanović, Marta; Tomić, Siniša

    2010-12-01

    The purpose of seasonal influenza vaccination is to prevent its spread. The vaccines contain strains of the influenza virus recommended and approved for a particular season. Just like any other medicinal product, all vaccines require marketing approval. Batches of approved vaccines are extensively tested by the manufacturers and additionally controlled by the approving authorities, which issue the quality control certificates. This article not only to describes the legal background of quality control, but also how control test results obtained by a Croatian official control laboratory are compared to manufacturer's results. We have found that testing results can slightly differ depending on methods/analytical procedures used in different laboratories. This investigation has also shown how important it is to test finished medicinal products, independently of testing at intermediate stages, and how retesting by control authorities ensures that marketed vaccines meet quality standards.

  12. Quality Controlled Local Climatological Data (QCLCD) Publication

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Quality Controlled Local Climatological Data (QCLCD) contains summaries from major airport weather stations that include a daily account of temperature extremes,...

  13. Production and quality control of iodine-123

    International Nuclear Information System (INIS)

    The various methods for production and quality control are discussed. The author feels the 123Xe-123I generator is the best method of production. Preparation and use of 123I-labeled compounds are also considered

  14. Open lung biopsy

    Science.gov (United States)

    Biopsy - open lung ... An open lung biopsy is done in the hospital using general anesthesia , which means you are asleep and pain- ... The open lung biopsy is done to evaluate lung problems seen on x-ray or CT scan .

  15. Muscle biopsy (image)

    Science.gov (United States)

    A muscle biopsy involves removal of a plug of tissue usually by a needle to be later used for examination. Sometimes ... there is a patchy condition expected an open biopsy may be used. Open biopsy involves a small ...

  16. Bone biopsy (image)

    Science.gov (United States)

    A bone biopsy is performed by making a small incision into the skin. A biopsy needle retrieves a sample of bone and it ... examination. The most common reasons for bone lesion biopsy are to distinguish between benign and malignant bone ...

  17. Network-based production quality control

    Science.gov (United States)

    Kwon, Yongjin; Tseng, Bill; Chiou, Richard

    2007-09-01

    This study investigates the feasibility of remote quality control using a host of advanced automation equipment with Internet accessibility. Recent emphasis on product quality and reduction of waste stems from the dynamic, globalized and customer-driven market, which brings opportunities and threats to companies, depending on the response speed and production strategies. The current trends in industry also include a wide spread of distributed manufacturing systems, where design, production, and management facilities are geographically dispersed. This situation mandates not only the accessibility to remotely located production equipment for monitoring and control, but efficient means of responding to changing environment to counter process variations and diverse customer demands. To compete under such an environment, companies are striving to achieve 100%, sensor-based, automated inspection for zero-defect manufacturing. In this study, the Internet-based quality control scheme is referred to as "E-Quality for Manufacturing" or "EQM" for short. By its definition, EQM refers to a holistic approach to design and to embed efficient quality control functions in the context of network integrated manufacturing systems. Such system let designers located far away from the production facility to monitor, control and adjust the quality inspection processes as production design evolves.

  18. Quality control in 99m technetium radiopharmaceuticals

    International Nuclear Information System (INIS)

    This work means about the quality control in Tc radiopharmaceuticals preparation at hospitalary levels. Several steps must be used in a Nuclear Medicine Laboratory, such as proceeding,radiopharmaceuticals kits preparation, and dispensation materials,glasses,stopper,physical aspects,identification,ph control,storage,and reactif kits

  19. Quality control standards in PGD and PGS.

    Science.gov (United States)

    SenGupta, S B; Dhanjal, S; Harper, J C

    2016-03-01

    Preimplantation genetic diagnosis (PGD) aims to test the embryo for specific conditions before implantation in couples at risk of transmitting genetic abnormality to their offspring. The couple must undergo IVF procedures to generate embryos in vitro. The embryos can be biopsied at either the zygote, cleavage or blastocyst stage. Preimplantation genetic screening uses the same technology to screen for chromosome abnormalities in embryos from patients undergoing IVF procedures as a method of embryo selection. Fluorescence in-situ hybridization was originally used for chromosome analysis, but has now been replaced by array comparative genomic hybridization or next generation sequencing. For the diagnosis of single gene defects, polymerase chain reaction is used and has become highly developed; however, single nucleotide polymorphism arrays for karyomapping have recently been introduced. A partnership between IVF laboratories and diagnostic centres is required to carry out PGD and preimplantation genetic screening. Accreditation of PGD diagnostic laboratories is important. Accreditation gives IVF centres an assurance that the diagnostic tests conform to specified standards. ISO 15189 is an international laboratory standard specific for medical laboratories. A requirement for accreditation is to participate in external quality assessment schemes. PMID:26776824

  20. Development of the gaharu oil quality control

    International Nuclear Information System (INIS)

    Gaharu (Agar wood) is a secondary metabolite produces by the Aquilaria spp. and accumulates in the plant cell in oleoresin form. The essential oil known as gaharu oil can be extracted from this oleoresin gaharu via varies extraction method such as the water distillation, solvent extraction, pressurize extraction and etc. The gaharu oil extracted through different methods will give different fragrances. Besides, different source of materials will also give different in chemical profiles. In gaharu oil trading market, most of the buyers request quality assurance from the gaharu oil manufacturer to assure the gaharu oil purchased meets their standard requirement. Since there is a demand on gaharu oil quality assurance then it become a need to develop the gaharu oil quality control method in order to have a standard quality control of gaharu oil presented in a certificate of analysis and verified by laboratory. (author)

  1. Quality Control of Wild Berries Honey Syrup

    Directory of Open Access Journals (Sweden)

    Laura Stan

    2013-11-01

    Full Text Available This paper presents the quality control parameters of wild berries honey syrup . The product was created in laboratory (wild berries: honey, 1:4 w/w and there were no changes recorded in overall quality over 6 months preservation at 1-2°C. Basic quality parameters of the product were evaluated: humidity, pH, acidity, hydroxymethylfurfural, diastase, total sugars and ascorbic acid. Methods developed by Internantional Honey Commission and Romanian Food Quality Standards were applied during this study. The product presented qood quality criteria and it was highly appreciated by consumers who tasted it. This study presents a valuable method to preserve fresh widberries in honey over a long period of time. The economical value of this experiment resides in making these fruits available outside the harvesting season.

  2. Harmonisation Initiatives of Copernicus Data Quality Control

    Science.gov (United States)

    Vescovi, F. D.; Lankester, T.; Coleman, E.; Ottavianelli, G.

    2015-04-01

    The Copernicus Space Component Data Access system (CSCDA) incorporates data contributions from a wide range of satellite missions. Through EO data handling and distribution, CSCDA serves a set of Copernicus Services related to Land, Marine and Atmosphere Monitoring, Emergency Management and Security and Climate Change. The quality of the delivered EO products is the responsibility of each contributing mission, and the Copernicus data Quality Control (CQC) service supports and complements such data quality control activities. The mission of the CQC is to provide a service of quality assessment on the provided imagery, to support the investigation related to product quality anomalies, and to guarantee harmonisation and traceability of the quality information. In terms of product quality control, the CQC carries out analysis of representative sample products for each contributing mission as well as coordinating data quality investigation related to issues found or raised by Copernicus users. Results from the product analysis are systematically collected and the derived quality reports stored in a searchable database. The CQC service can be seen as a privileged focal point with unique comparison capacities over the data providers. The comparison among products from different missions suggests the need for a strong, common effort of harmonisation. Technical terms, definitions, metadata, file formats, processing levels, algorithms, cal/val procedures etc. are far from being homogeneous, and this may generate inconsistencies and confusion among users of EO data. The CSCDA CQC team plays a significant role in promoting harmonisation initiatives across the numerous contributing missions, so that a common effort can achieve optimal complementarity and compatibility among the EO data from multiple data providers. This effort is done in coordination with important initiatives already working towards these goals (e.g. INSPIRE directive, CEOS initiatives, OGC standards, QA4EO

  3. Evaluating quality control of Wikipedia's feature articles

    OpenAIRE

    Lindsey, David

    2010-01-01

    The purpose of this study was to evaluate the effectiveness of Wikipedia’s internal quality control mechanism, the “featured article” process, which assesses articles against a stringent set of criteria. To this end, scholars were asked to evaluate the quality and accuracy of Wikipedia featured articles within their area of expertise. A total of 22 usable responses were collected from a variety of disciplines. Out of the Wikipedia articles assessed, only 12 of 22 were found to pass Wikiped...

  4. Protein quality control in the bacterial periplasm.

    Science.gov (United States)

    Merdanovic, Melisa; Clausen, Tim; Kaiser, Markus; Huber, Robert; Ehrmann, Michael

    2011-01-01

    Protein quality control involves sensing and treatment of defective or incomplete protein structures. Misfolded or mislocalized proteins trigger dedicated signal transduction cascades that upregulate the production of protein quality-control factors. Corresponding proteases and chaperones either degrade or repair damaged proteins, thereby reducing the level of aggregation-prone molecules. Because the periplasm of gram-negative bacteria is particularly exposed to environmental changes and respective protein-folding stresses connected with the presence of detergents, low or high osmolarity of the medium, elevated temperatures, and the host's immune response, fine-tuned protein quality control systems are essential for survival under these unfavorable conditions. This review discusses recent advances in the identification and characterization of the key cellular factors and the emerging general principles of the underlying molecular mechanisms. PMID:21639788

  5. Protein quality control in the nucleus

    DEFF Research Database (Denmark)

    Nielsen, Sofie V.; Poulsen, Esben Guldahl; Rebula, Caio A.;

    2014-01-01

    to aggregate, cells have evolved several elaborate quality control systems to deal with these potentially toxic proteins. First, various molecular chaperones will seize the misfolded protein and either attempt to refold the protein or target it for degradation via the ubiquitin-proteasome system...... to be particularly active in protein quality control. Thus, specific ubiquitin-protein ligases located in the nucleus, target not only misfolded nuclear proteins, but also various misfolded cytosolic proteins which are transported to the nucleus prior to their degradation. In comparison, much less is known about...... these mechanisms in mammalian cells. Here we highlight recent advances in our understanding of nuclear protein quality control, in particular regarding substrate recognition and proteasomal degradation....

  6. Frontiers in statistical quality control 11

    CERN Document Server

    Schmid, Wolfgang

    2015-01-01

    The main focus of this edited volume is on three major areas of statistical quality control: statistical process control (SPC), acceptance sampling and design of experiments. The majority of the papers deal with statistical process control, while acceptance sampling and design of experiments are also treated to a lesser extent. The book is organized into four thematic parts, with Part I addressing statistical process control. Part II is devoted to acceptance sampling. Part III covers the design of experiments, while Part IV discusses related fields. The twenty-three papers in this volume stem from The 11th International Workshop on Intelligent Statistical Quality Control, which was held in Sydney, Australia from August 20 to August 23, 2013. The event was hosted by Professor Ross Sparks, CSIRO Mathematics, Informatics and Statistics, North Ryde, Australia and was jointly organized by Professors S. Knoth, W. Schmid and Ross Sparks. The papers presented here were carefully selected and reviewed by the scientifi...

  7. HPLC for quality control of polyimides

    Science.gov (United States)

    Young, P. R.; Sykes, G. F.

    1979-01-01

    High Pressure Liquid Chromatography (HPLC) as a quality control tool for polyimide resins and prepregs are presented. A data base to help establish accept/reject criteria for these materials was developed. This work is intended to supplement, not replace, standard quality control tests normally conducted on incoming resins and prepregs. To help achieve these objectives, the HPLC separation of LARC-160 polyimide precursor resin was characterized. Room temperature resin aging effects were studied. Graphite reinforced composites made from fresh and aged resin were fabricated and tested to determine if changes observed by HPLC were significant.

  8. Quality control of nuclear medicine instruments 1991

    International Nuclear Information System (INIS)

    This document gives detailed guidance on the quality control of various instruments used in nuclear medicine. A first preliminary document was drawn up in 1979. A revised and extended version, incorporating recommended procedures, test schedules and protocols was prepared in 1982. The first edition of ''Quality Control of Nuclear Medicine Instruments'', IAEA-TECDOC-317, was printed in late 1984. Recent advances in the field of nuclear medicine imaging made it necessary to add a chapter on Camera-Computer Systems and another on SPECT Systems. Figs and tabs

  9. Role of dosimetry in quality control

    International Nuclear Information System (INIS)

    Dosimetry plays an important role in the quality control of radiation processing. Increasingly, quality control systems are based on the standards in the 9000 series from the International Organization for Standardization, ISO. This is true not only in radiation sterilization but also in food treatment, polymer modification and other uses of radiation. It is required that all measurements - including radiation measurements -are traceable to national standards, and the uncertainty of the measurements must be stated with appropriate confidence limits. The paper discusses the significance of dosimetry, the evaluation of uncertainty, and the way in which traceability may be obtained. (author). 11 refs, 2 tabs

  10. Statistical quality control a loss minimization approach

    CERN Document Server

    Trietsch, Dan

    1999-01-01

    While many books on quality espouse the Taguchi loss function, they do not examine its impact on statistical quality control (SQC). But using the Taguchi loss function sheds new light on questions relating to SQC and calls for some changes. This book covers SQC in a way that conforms with the need to minimize loss. Subjects often not covered elsewhere include: (i) measurements, (ii) determining how many points to sample to obtain reliable control charts (for which purpose a new graphic tool, diffidence charts, is introduced), (iii) the connection between process capability and tolerances, (iv)

  11. Quality control of rainfall measurements in Cyprus

    Science.gov (United States)

    Golz, Claudia; Einfalt, Thomas; Michaelides, Silas Chr.

    The basic condition for using precipitation data from raingauges and radars is data quality control. This aspect is important for comparing and using rainfall data, for example in models. In the scope of the EU-project VOLTAIRE (Validation of multisensors precipitation fields and numerical modelling in Mediterranean test sites) rain data from Cyprus have been analysed. Different quality control methods have been applied to the rainfall data of 158 raingauges and the data of 11 events (in 2002 and 2003) of the C-Band radar in Kykkos. The first results of the use of ground clutter algorithms for radar data in Cyprus are presented in the paper.

  12. Quality control of nuclear medicine instruments, 1991

    International Nuclear Information System (INIS)

    This document gives detailed guidance on the quality control of various instruments used in nuclear medicine. A first preliminary document was drawn up in 1979. A revised and extended version, incorporating recommended procedures, test schedules and protocols was prepared in 1982. The first edition of 'Quality Control of Nuclear Medicine Instruments', IAEA-TECDOC-317, was printed in late 1984. Recent advances in the field of nuclear medicine imaging made it necessary to add a chapter on Camera-Computer Systems and another on SPECT Systems

  13. Biopsy with the New Essen Biopsy Forceps

    Directory of Open Access Journals (Sweden)

    Peter G. Traine

    2013-01-01

    Full Text Available Purpose. To present initial experience with a novel biopsy method, the Essen biopsy forceps. Therefore, two patients with diagnostic suspicion of uveal melanoma underwent biopsy for histopathological confirmation. Case Presentation. Two patients presented with painless unilateral vision reduction. Ultrasound revealed the diagnostic suspicion of uveal melanoma. Therefore, biopsy with the Essen biopsy forceps using a sutureless 23-gauge three-port vitrectomy system was performed. The specimens were then submitted to a pathologist and processed. Histopathology of the obtained specimen confirmed the diagnostic suspicion of choroid melanoma in both patients. Conclusion. Essen biopsy forceps is a very practicable alternative method to the FNAB, allowing a combined histopathological and immunohistochemical examination for achieving high diagnostic accuracy at minimal risk.

  14. Skin biopsy: Biopsy issues in specific diseases.

    Science.gov (United States)

    Elston, Dirk M; Stratman, Erik J; Miller, Stanley J

    2016-01-01

    Misdiagnosis may result from biopsy site selection, technique, or choice of transport media. Important potential sources of error include false-negative direct immunofluorescence results based on poor site selection, uninformative biopsy specimens based on both site selection and technique, and spurious interpretations of pigmented lesions and nonmelanoma skin cancer based on biopsy technique. Part I of this 2-part continuing medical education article addresses common pitfalls involving site selection and biopsy technique in the diagnosis of bullous diseases, vasculitis, panniculitis, connective tissue diseases, drug eruptions, graft-versus-host disease, staphylococcal scalded skin syndrome, hair disorders, and neoplastic disorders. Understanding these potential pitfalls can result in improved diagnostic yield and patient outcomes.

  15. Quality control algorithms for rainfall measurements

    Science.gov (United States)

    Golz, Claudia; Einfalt, Thomas; Gabella, Marco; Germann, Urs

    2005-09-01

    One of the basic requirements for a scientific use of rain data from raingauges, ground and space radars is data quality control. Rain data could be used more intensively in many fields of activity (meteorology, hydrology, etc.), if the achievable data quality could be improved. This depends on the available data quality delivered by the measuring devices and the data quality enhancement procedures. To get an overview of the existing algorithms a literature review and literature pool have been produced. The diverse algorithms have been evaluated to meet VOLTAIRE objectives and sorted in different groups. To test the chosen algorithms an algorithm pool has been established, where the software is collected. A large part of this work presented here is implemented in the scope of the EU-project VOLTAIRE ( Validati on of mu ltisensors precipit ation fields and numerical modeling in Mediter ran ean test sites).

  16. Extracellular quality control in the epididymis

    Institute of Scientific and Technical Information of China (English)

    Gail A. Cornwall; H. Henning von Horsten; Douglas Swartz; Seethal Johnson; Kim Chau; Sandra Whelly

    2007-01-01

    The epididymal lumen represents a unique extracellular environment because of the active sperm maturation process that takes place within its confines. Although much focus has been placed on the interaction of epididymal secretory proteins with spermatozoa in the lumen, very little is known regarding how the complex epididymal milieu as a whole is maintained, including mechanisms to prevent or control proteins that may not stay in their native folded state following secretion. Because some misfolded proteins can form cytotoxic aggregate structures known as amyloid, it is likely that control/surveillance mechanisms exist within the epididymis to protect against this process and allow sperm maturation to occur. To study protein aggregation and to identify extracellular quality control mechanisms in the epididymis, we used the cystatin family of cysteine protease inhibitors, including cystatin-related epididymal spermatogenic and cystatin C as molecular models because both proteins have inherent properties to aggregate and form amyloid. In this chapter, we present a brief summary of protein aggregation by the amyloid pathway based on what is known from other organ systems and describe quality control mechanisms that exist intracellularly to control protein misfolding and aggregation. We then present a summary of our studies of cystatinrelated epididymal spermatogenic (CRES) oligomerization within the epididymal lumen, including studies suggesting that transglutaminase cross-linking may be one mechanism of extracellular quality control within the epididymis.

  17. Outsourcing University Degrees: Implications for Quality Control

    Science.gov (United States)

    Edwards, Julie; Crosling, Glenda; Edwards, Ron

    2010-01-01

    Education institutions worldwide have and continue to seek opportunities to spread their offerings abroad. While the provision of courses to students located overseas through partner institutions has many advantages, it raises questions about quality control that are not as applicable to other forms of international education. This paper uses a…

  18. Water quality control program in experimental circuits

    International Nuclear Information System (INIS)

    The Water Quality Control Program of the Experimental Circuits visualizes studying the water chemistry of the cooling in the primary and secondary circuits, monitoring the corrosion of the systems and studying the mechanism of the corrosion products transport in the systems. (author)

  19. Quality Control Of Selected Pesticides With GC

    International Nuclear Information System (INIS)

    The practical quality control of selected pesticides with GC is treated. Detailed descriptions are given on materials and methods used, including sample preparation and GC operating conditions. The systematic validation of multi methods is described, comprising performance characteristics in routine analysis, like selectivity, specificity etc. This is illustrated by chromatograms, calibration curves and tables derived from real laboratory data. (author)

  20. Net analyte signal based statistical quality control.

    Science.gov (United States)

    Skibsted, E T S; Boelens, H F M; Westerhuis, J A; Smilde, A K; Broad, N W; Rees, D R; Witte, D T

    2005-11-15

    Net analyte signal statistical quality control (NAS-SQC) is a new methodology to perform multivariate product quality monitoring based on the net analyte signal approach. The main advantage of NAS-SQC is that the systematic variation in the product due to the analyte (or property) of interest is separated from the remaining systematic variation due to all other compounds in the matrix. This enhances the ability to flag products out of statistical control. Using control charts, the analyte content, variation of other compounds, and residual variation can be monitored. As an example, NAS-SQC is used to appreciate the control content uniformity of a commercially available pharmaceutical tablet product measured with near-infrared spectroscopy. Using the NAS chart, the active pharmaceutical ingredient (API) content is easily monitored for new tablets. However, since quality is a multivariate property, other quality parameters of the tablets are also monitored simultaneously. It will be demonstrated that, besides the API content, the water content of the tablets as well as the homogeneity of the other compounds is monitored. PMID:16285655

  1. Materials, methods and quality control, ch. 3

    International Nuclear Information System (INIS)

    A description of the chemical reagents, the 125I-labelled angiotensin I, the antiserum and the standards is given. A modified measuring method with the New England Nuclear kit for angiotensin I radioimmunoassay is presented as well as the quality control data

  2. Statistical quality control through overall vibration analysis

    Science.gov (United States)

    Carnero, M. a. Carmen; González-Palma, Rafael; Almorza, David; Mayorga, Pedro; López-Escobar, Carlos

    2010-05-01

    The present study introduces the concept of statistical quality control in automotive wheel bearings manufacturing processes. Defects on products under analysis can have a direct influence on passengers' safety and comfort. At present, the use of vibration analysis on machine tools for quality control purposes is not very extensive in manufacturing facilities. Noise and vibration are common quality problems in bearings. These failure modes likely occur under certain operating conditions and do not require high vibration amplitudes but relate to certain vibration frequencies. The vibration frequencies are affected by the type of surface problems (chattering) of ball races that are generated through grinding processes. The purpose of this paper is to identify grinding process variables that affect the quality of bearings by using statistical principles in the field of machine tools. In addition, an evaluation of the quality results of the finished parts under different combinations of process variables is assessed. This paper intends to establish the foundations to predict the quality of the products through the analysis of self-induced vibrations during the contact between the grinding wheel and the parts. To achieve this goal, the overall self-induced vibration readings under different combinations of process variables are analysed using statistical tools. The analysis of data and design of experiments follows a classical approach, considering all potential interactions between variables. The analysis of data is conducted through analysis of variance (ANOVA) for data sets that meet normality and homoscedasticity criteria. This paper utilizes different statistical tools to support the conclusions such as chi squared, Shapiro-Wilks, symmetry, Kurtosis, Cochran, Hartlett, and Hartley and Krushal-Wallis. The analysis presented is the starting point to extend the use of predictive techniques (vibration analysis) for quality control. This paper demonstrates the existence

  3. The role and relevance of quality assurance to quality control

    International Nuclear Information System (INIS)

    The paper describes the development of Quality Assurance as a total management technique, incorporating manufacturing and construction Quality Control, to give confidence of satisfactory in-service performance. The application of QA to the Heysham 2 and Torness AGR projects design and construction is defined with particular reference to the development of a QA requirements specification, delegation of QA responsibility through the hierarchy of purchasers and suppliers of plant and material, the role of the QA organization and QA auditing. The paper discusses the effectiveness and benefits of QA and the problems identified in its application and implementation. The problems, their solutions and longer term improvements to reduce the costs of QA as well as enhancing confidence in the satisfactory performance of future nuclear projects, are described. (author)

  4. 42 CFR 84.41 - Quality control plans; contents.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Quality control plans; contents. 84.41 Section 84... AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Quality Control § 84.41 Quality control plans; contents. (a) Each quality control plan shall contain provisions for...

  5. Determination and evaluation of air quality control. Manual of ambient air quality control in Germany

    Energy Technology Data Exchange (ETDEWEB)

    Lahmann, E.

    1997-07-01

    Measurement of air pollution emissions and ambient air quality are essential instruments for air quality control. By undertaking such measurements, pollutants are registered both at their place of origin and at the place where they may have an effect on people or the environment. Both types of measurement complement each other and are essential for the implementation of air quality legislation, particularly, in compliance with emission and ambient air quality limit values. Presented here are similar accounts of measurement principles and also contains as an Appendix a list of suitability-tested measuring devices which is based on information provided by the manufacturers. In addition, the guide of ambient air quality control contains further information on discontinuous measurement methods, on measurement planning and on the assessment of ambient air quality data. (orig./SR)

  6. Bone marrow biopsy

    Science.gov (United States)

    Biopsy - bone marrow ... A bone marrow biopsy may be done in the health care provider's office or in a hospital. The sample may be taken from the pelvic or breast bone. Sometimes, other areas are used. Marrow is removed ...

  7. Cold knife cone biopsy

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/003910.htm Cold knife cone biopsy To use the sharing features on this page, please enable JavaScript. A cold knife cone biopsy (conization) is surgery to remove ...

  8. Mediastinoscopy with biopsy

    Science.gov (United States)

    ... medlineplus.gov/ency/article/003864.htm Mediastinoscopy with biopsy To use the sharing features on this page, please enable JavaScript. Mediastinoscopy with biopsy is a procedure in which a lighted instrument ( ...

  9. Sentinel Lymph Node Biopsy

    Science.gov (United States)

    ... Ask about Your Diagnosis Research Sentinel Lymph Node Biopsy On This Page What are lymph nodes? What ... lymph node? What is a sentinel lymph node biopsy? What happens during an SLNB? What are the ...

  10. Nerve biopsy (image)

    Science.gov (United States)

    Nerve biopsy is the removal of a small piece of nerve for examination. Through a small incision, a sample ... is removed and examined under a microscope. Nerve biopsy may be performed to identify nerve degeneration, identify ...

  11. Protein quality control in the nucleus.

    Science.gov (United States)

    Jones, Ramon D; Gardner, Richard G

    2016-06-01

    The nucleus is the repository for the eukaryotic cell's genetic blueprint, which must be protected from harm to ensure survival. Multiple quality control (QC) pathways operate in the nucleus to maintain the integrity of the DNA, the fidelity of the DNA code during replication, its transcription into mRNA, and the functional structure of the proteins that are required for DNA maintenance, mRNA transcription, and other important nuclear processes. Although we understand a great deal about DNA and RNA QC mechanisms, we know far less about nuclear protein quality control (PQC) mechanisms despite that fact that many human diseases are causally linked to protein misfolding in the nucleus. In this review, we discuss what is known about nuclear PQC and we highlight new questions that have emerged from recent developments in nuclear PQC studies. PMID:27015023

  12. Progress in gamma-camera quality control

    International Nuclear Information System (INIS)

    The latest developments in the art of quality control of gamma cameras are emphasized in a simple historical manner. The exhibit describes methods developed by the Bureau of Radiological Health (BRH) in comparison with previously accepted techniques for routine evaluation of gamma-camera performance. Gamma cameras require periodic testing of their performance parameters to ensure that their optimum imaging capability is maintained. Quality control parameters reviewed are field uniformity, spatial distortion, intrinsic and spatial resolution, and temporal resolution. The methods developed for the measurement of these parameters are simple, not requiring additional electronic equipment or computers. The data has been arranged in six panels as follows: schematic diagrams of the most important test patterns used in nuclear medicine; field uniformity; regional displacements in transmission pattern image; spatial resolution using the BRH line-source phantom; instrinsic resolution using the BRH Test Pattern; and Temporal resolution and count losses at high counting rates

  13. Quality Control in Dental Radiology in Greece

    International Nuclear Information System (INIS)

    Quality control was implemented in 52 dental intra-oral X ray units in use in the public and private sector in Hellas. The protocol consisted of visual inspection of the X ray unit, complete registration of the unit's characteristics, measurement of the unit's radiological parameters, inspection of the radiation protection facilities for patient and personnel and examination of film processing conditions. The results are characterised by the large number of old X ray units, the great variability in entrance surface doses and linearity of output and the absence of strict patient and operator radiation protection measures. Analogue exposure timers have very poor accuracy compared to digital ones. Imaging techniques and film processing do not always comply with standards among dentists. In view of the above, the implementation of a Quality Control programme, including reference doses, which could, for example, be selected according to the results of this paper, is strongly recommended in Dental Radiology in Hellas. (author)

  14. Quality control of nuclear medicine equipment

    International Nuclear Information System (INIS)

    In order to determine functional status and integrity of installations and equipment used in nuclear medicine in everyday medical practice or in research studies, it is important to maintain and implement quality control program. For this type of installation are required high standards, particularly with regard to qualitative and quantitative analysis of the image, and volume measurements in diagnosis and dosimetry. Given the precarious situation of the economy in transition, nuclear medicine departments in the republic, now, can not be always of service contracts with providers of facilities and equipment for routine maintenance and periodic calibration. Therefore, in this article are at some of the quality control procedures should be performed usually by engineers and physicists from the department of nuclear medicine. (authors)

  15. Percutaneous liver biopsy.

    Science.gov (United States)

    Rustagi, Tarun; Newton, Eric; Kar, Premashish

    2010-01-01

    Percutaneous liver biopsy has been performed for more than 120 years, and remains an important diagnostic procedure for the management of hepatobiliary disorders. Modern biochemical, immunologic, and radiographic techniques have facilitated the diagnosis and management of liver diseases but have not made liver biopsy obsolete. This comprehensive review article will discuss the history of development of percutaneous liver biopsy, its indications, contraindications, complications and the various aspects of the biopsy procedure in detail.

  16. Towards quality control of food using terahertz

    Science.gov (United States)

    Ung, B. S.-Y.; Fischer, B. M.; Ng, B. W.-H.; Abbott, D.

    2007-12-01

    Terahertz radiation or T-rays, show promise in quality control of food products. As T-rays are inherently sensitive to water, they are very suitable for moisture detection. This proves to be a valuable asset in detecting the moisture content of dried food, a critical area for some products. As T-rays are transparent to plastics, food additives can also be probed through the packaging, providing checks against a manufacturer's claims, such as the presence of certain substances in foods.

  17. Glycoprotein Quality Control and Endoplasmic Reticulum Stress

    Directory of Open Access Journals (Sweden)

    Qian Wang

    2015-07-01

    Full Text Available The endoplasmic reticulum (ER supports many cellular processes and performs diverse functions, including protein synthesis, translocation across the membrane, integration into the membrane, folding, and posttranslational modifications including N-linked glycosylation; and regulation of Ca2+ homeostasis. In mammalian systems, the majority of proteins synthesized by the rough ER have N-linked glycans critical for protein maturation. The N-linked glycan is used as a quality control signal in the secretory protein pathway. A series of chaperones, folding enzymes, glucosidases, and carbohydrate transferases support glycoprotein synthesis and processing. Perturbation of ER-associated functions such as disturbed ER glycoprotein quality control, protein glycosylation and protein folding results in activation of an ER stress coping response. Collectively this ER stress coping response is termed the unfolded protein response (UPR, and occurs through the activation of complex cytoplasmic and nuclear signaling pathways. Cellular and ER homeostasis depends on balanced activity of the ER protein folding, quality control, and degradation pathways; as well as management of the ER stress coping response.

  18. 7 CFR 58.335 - Quality control tests.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Quality control tests. 58.335 Section 58.335... Procedures § 58.335 Quality control tests. All milk, cream and related products are subject to inspection for quality and condition throughout each processing operation. Quality control tests shall be made on...

  19. Adaptive quality control for multimedia communications

    Directory of Open Access Journals (Sweden)

    Santichai Chuaywong

    2008-01-01

    Full Text Available Multimedia communications are communications with several types of media, such as audio, video and data. The current Internet has some levels of capability to support multimedia communications, unfortunately, the QoS (Quality of Service is still challenging. A large number of QoS mechanisms has been proposed; however, the main concern is for low levels, e.g. layer 2 (Data Link or 3 (Transport. In this paper, mechanisms for control the quality of audio and video are proposed. G.723.1 and MPEG-4 are used as the audio and video codec respectively. The proposed algorithm for adaptive quality control of audio communication is based on forward error correction (FEC. In the case of video communication, the proposed algorithm adapts the value of key frame interval, which is an encoding parameter of MPEG-4. We evaluated our proposed algorithms by computer simulation. We have shown that, in most cases, the proposed scheme gained a higher throughput compared to other schemes.

  20. Quality Management of CERN Vacuum Controls

    CERN Document Server

    Antoniotti, F; Fortescue-Beck, E; Gama, J; Gomes, P; Le Roux, P; Pereira, H; Pigny, G

    2014-01-01

    The vacuum controls Section (TE-VSC-ICM) is in charge of the monitoring, maintenance and consolidation of the control systems of all accelerators and detectors in CERN; this represents 6 000 instruments distributed along 128 km of vacuum chambers, often of heterogeneous architectures and of diverse technical generations. In order to improve the efficiency of the services provided by ICM, to vacuum experts and to accelerator operators, a Quality Management Plan is being put into place. The first step was the standardization of the naming convention across different accelerators. The traceability of problems, requests, repairs, and other actions, has also been put into place (VTL). This was combined with the effort to identify each individual device by a coded label, and register it in a central database (MTF). Occurring in parallel, was the gathering of old documents and the centralization of information concerning architectures, procedures, equipment and settings (EDMS). To describe the topology of control c...

  1. Radar data quality control methods in VOLTAIRE

    Energy Technology Data Exchange (ETDEWEB)

    Golz, C.; Einfalt, T. [einfalt und hydrotec GbR, Luebeck (Germany); Galli, G. [MeteoSvizzera, Locarno-Monti (Switzerland)

    2006-10-15

    In the scope of the EU-project VOLTAIRE (Validation of multisensors precipitation fields and numerical modelling in Mediterranean test sites) a software library for automatic and rapid radar data quality check and modification has been developed and tests have been performed with data from different countries. Automatic procedures will never replace an experienced observer, but they help him to do his work and they can be used at places, where observation is not possible.This paper gives an overview over the algorithms that have been adopted or developed during the VOLTAIRE project for radar data quality control. Two examples of these algorithms illustrate the possibilities for data correction but also their limitations. These examples are a clutter correction combined with speckle removal for plan position indicator (PPI) data in particular of non-Doppler radars and a beam blockage correction for PPI data, where no digital elevation model (DEM) is available. (orig.)

  2. Progress in quality control of alanine dosimeters

    International Nuclear Information System (INIS)

    The ESR/alanine system has been used for different applications, over several years, as a classical routine dosimetry service. This service is based on alanine dosimeters constituted by pellets manufactured by our laboratory, which are presented with some specifications of use and different parameters bound to the intrinsic quality of the dosimeter itself. These parameters were obtained through the strict application of a production protocol and a validation protocol created, tested and validated under a quality assurance system. Every year, one batch of photon dosimeters is produced and controlled using these protocols and the specifications associated with it are checked. Two categories of data are considered separately: physical parameters and experimental data obtained by measurement on our ESR system are given with their associated standard deviation. (author)

  3. Needle Biopsy of the Lung

    Science.gov (United States)

    ... Physician Resources Professions Site Index A-Z Needle Biopsy of the Lung Needle biopsy of the lung ... Needle Biopsy of Lung Nodules? What is Needle Biopsy of the Lung? A lung nodule is relatively ...

  4. Ultrasound-Guided Breast Biopsy

    Science.gov (United States)

    ... Professions Site Index A-Z Ultrasound-Guided Breast Biopsy An ultrasound-guided breast biopsy uses sound waves ... Guided Breast Biopsy? What is Ultrasound-Guided Breast Biopsy? Lumps or abnormalities in the breast are often ...

  5. Stereotactic (Mammographically Guided) Breast Biopsy

    Science.gov (United States)

    ... Resources Professions Site Index A-Z Stereotactic Breast Biopsy Stereotactic breast biopsy uses mammography – a specific type ... Breast Biopsy? What is Stereotactic (Mammographically Guided) Breast Biopsy? Lumps or abnormalities in the breast are often ...

  6. 7 CFR 58.141 - Alternate quality control program.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Alternate quality control program. 58.141 Section 58... Service 1 Quality Specifications for Raw Milk § 58.141 Alternate quality control program. When a plant has in operation an acceptable quality program, at the producer level, which is approved by...

  7. Efficacy of video assisted thoracoscopic lung biopsy: an historical comparison with open lung biopsy.

    OpenAIRE

    Carnochan, F. M.; Walker, W. S.; Cameron, E W

    1994-01-01

    BACKGROUND--Video assisted thoracoscopic lung biopsies were compared with historical controls undergoing open lung biopsy to determine the diagnostic accuracy, effect on length of postoperative stay, and cost effectiveness of the new thoracoscopic technique. METHODS--The first 25 video assisted thoracoscopic lung biopsies performed in the Edinburgh Thoracic Unit were compared with 25 historical controls for complications, diagnostic accuracy, and length of postoperative stay. RESULTS--Statist...

  8. 'Microerosions' in rectal biopsies in Crohn's disease

    DEFF Research Database (Denmark)

    Poulsen, Steen Seier

    1984-01-01

    Small (less than 1 mm), superficial erosions ('microerosions') have been observed stereo-microscopically in surface-stained rectal biopsies in Crohn's disease (CD). Biopsy specimens from 97 patients with CD, 225 with ulcerative colitis (UC), and a control material of 161 patients were investigated...

  9. Quality assurance and quality control in fabrication of cladding tubes

    International Nuclear Information System (INIS)

    Zircaloy 2 and 4 are the most important Zirconium alloys for use as fuel cladding material in light and heavy water reactors. In fast breeder reactors the cladding tubes are of a modified 16/16 - Cr-Ni-type with improved mechanical, long - term creep rate and rupture - life versus temperature properties. Starting with hot-extruded tube shells the fabrication of Zircaloy cladding tubes is done by 3 - 4 cold reduction steps in tube reducers or rolling machines followed by heat treatments in vacuum. To obtain the specified properties a precise combination of final area reduction and final annealing is absolutely necessary. The fabrication route of stainless steel claddings and guide tubes is similar to the Zircaloy production, exceptionally the last cold-forming steps are made on cold-drawing henches, hecause of economic reasons. After each cold reduction the material is annealed at recrystalisation temperatures under protective atmosoheres. For obtaining the same final tube properties for a longer nroduction neriod the implementation of a quality assurance and control system naturally independent of the production is necessary. The application of this system regarding some of the important properties of fuel cladding tubes is reported. (RW)

  10. Quality Control, Quality Assurance, and Quality Improvement-What is the Difference and Why Should Compounding Pharmacies Care?

    Science.gov (United States)

    Cabaleiro, Joe

    2009-01-01

    This article provides scenarios of three different pharmacies in the areas of quality control, quality assurance, and quality improvement. The scenarios show the importance that each pharmacy placed on a problem of dented capsules and the potential impact that an unresolved problem can have on a compounding pharmacy's business. Although this article focuses on one particular procedure, the purpose of th article is to help pharmacists understand the differences between quality control, quality assurance, and quality improvement. PMID:23966522

  11. 7 CFR 275.21 - Quality control review reports.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 4 2010-01-01 2010-01-01 false Quality control review reports. 275.21 Section 275.21... Reporting on Program Performance § 275.21 Quality control review reports. (a) General. Each State agency shall submit reports on the performance of quality control reviews in accordance with the...

  12. 21 CFR 864.8625 - Hematology quality control mixture.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hematology quality control mixture. 864.8625... quality control mixture. (a) Identification. A hematology quality control mixture is a device used to... parameters such as white cell count (WBC), red cell count (RBC), platelet count (PLT), hemoglobin,...

  13. US-guided biopsy of renal allografts using 18G biopsy gun: analysis of 200 cases

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Eun Kyung; Lee, Jong Tae; Kim, Myeong Jin; Yoo, Hyung Sik; Kim, Ki Whang; Park, Ki Ill; Chung, Hyun Joo [Yonsei University, College of Medicine, Seoul (Korea, Republic of)

    1995-05-15

    We evaluated the effectiveness and safety of 18G biopsy gun with US guidance in the transplanted kidneys. We performed 200 US-guided percutaneous biopsies using 18G biopsy gun. Diagnostic efficacy and complication of the biopsy in these patients were analyzed. Biopsy specimens were adequate for histologic diagnoses in 193 patients(96.5%). The mean of the biopsy frequency was 3, the mean of total glomerular number was 21.64 and the mean glomerular number per one biopsy was 6.93. Major complications occurred in 3 (1.5%) of the 200 biopsies; hematuria developed in two patients, AV fistula in one. These complications were successfully controlled either by only transfusion or by coil embolization. There were no statistical differences in blood pressure, hemoglobin, BUN/Cr between pre-and post-renal biopsies. US-guided percutaneous biopsy of renal allograft with 18G biopsy gun is simple, safe, and accurate method in evaluating the renal allograft dysfunction.

  14. 40 CFR 75.21 - Quality assurance and quality control requirements.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 16 2010-07-01 2010-07-01 false Quality assurance and quality control... PROGRAMS (CONTINUED) CONTINUOUS EMISSION MONITORING Operation and Maintenance Requirements § 75.21 Quality assurance and quality control requirements. (a) Continuous emission monitoring systems. The owner...

  15. Quality control in nuclear fuel fabrication

    International Nuclear Information System (INIS)

    The department of metallurgy, NRC Inchass is embarking on a programme of on a laboratory scale, fuel pins containing uranium dioxide pellets are going to be produced. The department is making use of the expertise and equipment at present available and is going to utilize the new fuel pin fabrication unit which would be shortly in operation. The fabrication and testing of uranium dioxide pellets then gradually adapt them and develop, a national know how in this field. This would also involve building up of indigenous experience through proper training of qualified personnel. That are applied to ensure quality of U o2 pellets, the techniques implemented, the equipment used and the specifications of the equipment presently available. The following parameters are subject to quality control tests: density. O/U ration, hydrogen content, microstructure, each property will be discussed, measurements related to U o2 powders, including flow ability, bulk density, O/U ratio, bet surface area and water content will be critically discussed. Relevant tests to ensure Q C of pellets are reviewed. These include surface integrity, density, dimensions, microstructure.4 fig., 1 tab

  16. Quality control of ATLAS muon chambers

    CERN Document Server

    Fabich, Adrian

    ATLAS is a general-purpose experiment for the future Large Hadron Collider (LHC) at CERN. Its Muon Spectrometer will require ∼ 5500m2 of precision tracking chambers to measure the muon tracks along a spectrometer arm of 5m to 15m length, embedded in a magnetic field of ∼ 0.5T. The precision tracking devices in the Muon System will be high pressure drift tubes (MDTs). Approximately 370,000 MDTs will be assembled into ∼ 1200 drift chambers. The performance of the MDT chambers is very much dependent on the mechanical quality of the chambers. The uniformity and stability of the performance can only be assured providing very high quality control during production. Gas tightness, high-voltage behaviour and dark currents are global parameters which are common to gas detectors. For all chambers, they will be tested immediately after the chamber assembly at every production site. Functional tests, for example radioactive source scans and cosmic-ray runs, will be performed in order to establish detailed performan...

  17. Quality control tests for conventional mammography

    International Nuclear Information System (INIS)

    Mammography is this the test that allows the radiologist to look at images of the inside of the breasts. Mammograms help detect breast cancer early successful treatment of breast cancer depends on that early diagnosis. Breast cancer is a very common condition. About one in every nine women develops breast cancer by the age of eighty. In addition to the clinical examination and self-examination, mammography plays important role in the detection of breast cancer before they become clinically visible tumors. The mammography is the most common test for early detection of breast cancer. Quality control techniques that done ensured importance of this programme to produce images with good diagnostic values and help radiologist to diagnose breast discase easily and avoid exposing patient to radiation hazards.(Author)

  18. Terms and definitions of quality assurance/quality control

    International Nuclear Information System (INIS)

    Terms of quality assurance are defined and interpreted. Reference is made to the IAEA Code of Practice and to other important Codes and Standards like ANSI, ASME and KTA. The relevance of these terms to everyday's work and problems of a quality assurance engineer is explained. (orig.)

  19. Quality control of antibodies for assay development.

    Science.gov (United States)

    Schumacher, Sarah; Seitz, Harald

    2016-09-25

    Antibodies are used as powerful tools in basic research, for example, in biomarker identification, and in various forms for diagnostics, for example, identification of allergies or autoimmune diseases. Due to their robustness and ease of handling, immunoassays are favourite methods for investigation of various biological or medical questions. Nevertheless in many cases, additional analyses such as mass spectrometry are used to validate or confirm the results of immunoassays. To minimize the workload and to increase confidence in immunoassays, there are urgent needs for antibodies which are both highly specific and well validated. Unfortunately many commercially available antibodies are neither well characterized nor fully tested for cross-reactivities. Adequate quality control and validation of an antibody is time-consuming and can be frustrating. Such validation needs to be performed for every assay/application. However, where an antibody validation is successful, a highly specific and stable reagent will be on hand. This article describes the validation processes of antibodies, including some often neglected factors, as well as unspecific binding to other sample compounds in a multiparameter diagnostic assay. The validation consists of different immunological methods, with important assay controls, and is performed in relation to the development of a diagnostic test. PMID:26873787

  20. 21 CFR 111.117 - What quality control operations are required for equipment, instruments, and controls?

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 2 2010-04-01 2010-04-01 false What quality control operations are required for equipment, instruments, and controls? 111.117 Section 111.117 Food and Drugs FOOD AND DRUG ADMINISTRATION... and Process Control System: Requirements for Quality Control § 111.117 What quality control...

  1. Improved transvenous liver biopsy needle

    DEFF Research Database (Denmark)

    Henriksen, Jens Henrik Sahl; Matzen, P; Christoffersen, P;

    1979-01-01

    A modified type of the standard transvenous cholangiography biopsy needle is described. The modified tranvenous liver biopsy needle caused only minimal artefactual changes of the liver biopsy specimens. The new type of biopsy needle is a modified Menghini needle. The conventional Menghini needle...... should be avoided for transvenous catheter biopsies because of risk of leaving catheter fragments in the liver....

  2. [Percutaneous biopsy of the liver].

    Science.gov (United States)

    Skladaný, L; Jarcuska, P; Oltman, M; Hrusovský, S

    2003-08-01

    Percutaneous liver biopsy represents the most specific examination of the nature and severity of liver diseases. P. Ehrlich was the first physician in history having done the intervention in 1880. The new history begins with the Menghini's publication on s.c. one-second biopsy in 1957. The present paper deals exclusively with diffuse diseases of the liver including the most frequent ones--virus hepatitis, alcohol and non-alcohol steatohepatitis. The contraindications include mainly coagulation disorders and non-cooperative patients. The percutaneous biopsy is mostly executed after ultrasonographic examination or under the control of various image-forming techniques and by means of various types of needles; the authors analyze advantages and disadvantages of individual techniques. If the contraindications are respected, the percutaneous biopsy is a safe method of examination, which may be done on out-patient basis. A large series of complications exists, but their frequency is generally low. Morbidity is referred in 0.2% of patients, the most frequent complications being pain and hypotension from vaso-vagal reactions, extensive intraperitoneal bleeding and hemobilia. Mortality is extremely low, the mean in large studies being 0.001%. PMID:14518095

  3. Minimal requirements for quality controls in radiotherapy with external beams

    International Nuclear Information System (INIS)

    Physical dosimetric guidelines have been developed by the Italian National Institute of Health study group on quality assurance in radiotherapy to define protocols for quality controls in external beam radiotherapy. While the document does not determine strict rules or firm recommendations, it suggests minimal requirements for quality controls necessary to guarantee an adequate degree of accuracy in external beam radiotherapy

  4. Biopsy pathology in uveitis

    Directory of Open Access Journals (Sweden)

    Jyotirmay Biswas

    2011-01-01

    Full Text Available Uveitis is fraught with speculations and suppositions with regard to its etiology, progress and prognosis. In several clinical scenarios what may be perceived as due to a systemic infection may actually not be so and the underlying etiology may be an autoimmune process. Investigations in uveitis are sometimes the key in identification and management. Invasive techniques could be of immense value in narrowing down the etiology and help in identifying the cause. This article updates one on the invasive techniques used in biopsy such as anterior chamber paracentesis, vitreous tap and diagnostic vitrectomy, iris and ciliary body biopsy, choroidal and retinochoroidal biopsy and fine needle aspiration biopsy (FNAB. In populations where certain infections are endemic, the clinical scenario does not always respect a known presentation and the use of biopsy is resorted to as a sure way of confirming the etiology. Biopsies have a role in diagnosis of several inflammatory and infectious conditions in the eye and are pivotal in diagnosis in several dilemmas such as intraocular tumors and in inflammations. Appropriate and timely use of biopsy in uveitis could enhance the diagnosis and provide insight into the etiology, thus enabling precise management.

  5. Freezing of testicular tissue as a minced suspension preserves sperm quality better than whole-biopsy freezing when glycerol is used as cryoprotectant.

    Science.gov (United States)

    Crabbé, E; Verheyen, G; Tournaye, H; Van Steirteghem, A

    1999-02-01

    Frozen-thawed testicular spermatozoa have been used successfully for ICSI, especially in cases of obstructive azoospermia with normal spermatogenesis. Fewer attempts, however, have been made to check whether these rather immature spermatozoa, in a different environment with several other cell types present, have cryobiological requirements other than those of ejaculated spermatozoa. This is the reason why the freezing protocols and cryoprotectants (glycerol) used for freezing testicular tissue are based on experience with semen freezing. This study aimed to assess whether cryosurvival and/or motility was influenced by freezing of testicular tissue either as an intact biopsy or as a shredded tissue suspension, when glycerol was used as cryoprotectant. Freezing of testicular tissue as a suspension preserved motility (type B + C) significantly better than freezing of whole biopsies (9.2% vs. 4.0%). Similar observations have been made for vitality (39.3% vs. 25.4%). Centrifugation on 50% Percoll in order to remove the cryoprotectant resulted in a huge loss of spermatozoa (or late spermatids) and should therefore be especially avoided in cases of testicular failure. On the basis of these observations, mincing of the testicular biopsies before freezing may be advocated. Testicular spermatozoa seem to be better preserved when frozen in suspension, at least when slowly permeating glycerol is used as a cryoprotectant. PMID:10068943

  6. No need for biopsies

    DEFF Research Database (Denmark)

    Gjødsbøl, Kristine; Skindersoe, Mette E; Christensen, Jens Jørgen;

    2011-01-01

    The aim of the study was to compare three sampling techniques used in routine diagnostics to identify the microbiota in chronic venous leg ulcers. A total of 46 patients with persisting venous leg ulcers were included in the study. At inclusion, swab, biopsy and filter paper pad samples were...... collected. After 4 weeks, additional biopsy and filter paper pad samples were collected. Bacteria were isolated and identified at species level by standard methods. The most common bacterial species detected was Staphylococcus aureus found in 89% of the ulcers. No methicillin-resistant S. aureus isolates...... species present in chronic wounds, thus avoiding complications during and after biopsy sampling....

  7. Concrete and steel construction quality control and assurance

    CERN Document Server

    El-Reedy, Mohamed A

    2014-01-01

    Starting with the receipt of materials and continuing all the way through to the final completion of the construction phase, Concrete and Steel Construction: Quality Control and Assurance examines all the quality control and assurance methods involving reinforced concrete and steel structures. This book explores the proper ways to achieve high-quality construction projects, and also provides a strong theoretical and practical background. It introduces information on quality techniques and quality management, and covers the principles of quality control. The book presents all of the quality control and assurance protocols and non-destructive test methods necessary for concrete and steel construction projects, including steel materials, welding and mixing, and testing. It covers welding terminology and procedures, and discusses welding standards and procedures during the fabrication process, as well as the welding codes. It also considers the total quality management system based on ISO 9001, and utilizes numer...

  8. Quality assurance and quality control of nuclear analytical techniques

    International Nuclear Information System (INIS)

    Test and analytical laboratories in East and Central European countries need to prove the reliability and credibility of their economic, environmental, medical and legal decisions and their capacity of issuing reliable, verifiable reports. These demands imposed by the European Union aimed at avoiding a possible barrier to trade for the developing countries. In June 1999, in order to help Member States to develop according to EU objectives and the overall situation of the European market, IAEA launched a new co-operation programme designed to help the nuclear analytical laboratories in nuclear institutions and universities of Member States by training in the use of some Nuclear Analytical Techniques (NAT) that include: alpha, beta and gamma-ray spectrometry, radiochemical and neutron activation analysis, total reflection X-ray fluorescence. The Regional IAEA Project, named 'Quality Assurance/Quality Control of Nuclear Analytical Techniques' (NAT) aims at implementing the QA principles via a system of defined consecutive steps leading to a level on which the QA system is self-sustainable for formal accreditation or certification and satisfies the EU technical performance criteria; the requirements are in accordance with the new ISO/IEC 17025 Standard/Dec.1999 'General requirements for the competence of testing and calibration laboratories' - First edition. The Horia Hulubei National Institute for Nuclear Physics and Engineering, IFIN-HH, was admitted for participation in the IAEA Project in June 1999 account taken of its experience in the QA and metrology fields and its performance in the fields of beta and gamma-ray spectrometry, and radiochemical and neutron activation analysis, employed in both basic research and applications for external clients. Two working groups of specialists with the QA and Standardization and Metrology Departments and six analytical groups with the departments of Nuclear Applied Physics, Life Physics and Ionising Radiation Metrology are

  9. The quality control theory of aging

    Directory of Open Access Journals (Sweden)

    Warren Ladiges

    2014-05-01

    Full Text Available The quality control (QC theory of aging is based on the concept that aging is the result of a reduction in QC of cellular systems designed to maintain lifelong homeostasis. Four QC systems associated with aging are 1 inadequate protein processing in a distressed endoplasmic reticulum (ER; 2 histone deacetylase (HDAC processing of genomic histones and gene silencing; 3 suppressed AMPK nutrient sensing with inefficient energy utilization and excessive fat accumulation; and 4 beta-adrenergic receptor (BAR signaling and environmental and emotional stress. Reprogramming these systems to maintain efficiency and prevent aging would be a rational strategy for increased lifespan and improved health. The QC theory can be tested with a pharmacological approach using three well-known and safe, FDA-approved drugs: 1 phenyl butyric acid, a chemical chaperone that enhances ER function and is also an HDAC inhibitor, 2 metformin, which activates AMPK and is used to treat type 2 diabetes, and 3 propranolol, a beta blocker which inhibits BAR signaling and is used to treat hypertension and anxiety. A critical aspect of the QC theory, then, is that aging is associated with multiple cellular systems that can be targeted with drug combinations more effectively than with single drugs. But more importantly, these drug combinations will effectively prevent, delay, or reverse chronic diseases of aging that impose such a tremendous health burden on our society.

  10. QUALITY CONTROL OF SOME TRADITIONAL MEAT PRODUCTS

    Directory of Open Access Journals (Sweden)

    S. DOBRINAS

    2014-03-01

    Full Text Available In this paper, we present the characterization of six traditional meat products: smoked file, smoked bacon, pork sausages, sausage prepared from swine’s entrails, pork pastrami, sheep sausages. Organoleptic tests (the aspect and shape, the aspect of freshly cut in the section, smell, taste and consistency, physico-chemical and microbiological determinations (NTG, Salmonella, Listeria monocytogenes and Escherichia coli were performed. These analyzes are a part of quality control that must be done in order to obtain a certificate from the Ministry of Agriculture for a traditional product. After identification of H2S and starch and according to fat oxidation degree it was concluded that analyzed samples didn’t contain counterfeiters and all parameters analyzed are within the maximum limits allowed by law. Considering all the procedures for manufacturing, characteristics of raw and auxiliary materials, organoleptic properties of final products analyzed in this study, it can be concluded that analyzed meat specialties meet the requirements of Ministry Order no. 690/28.09.2004 for the traditional products certification.

  11. MITOCHONDRIA QUALITY CONTROL AND MUSCLE MASS MAINTENANCE

    Directory of Open Access Journals (Sweden)

    Vanina eRomanello

    2016-01-01

    Full Text Available Loss of muscle mass and force occurs in many diseases such as disuse/inactivity, diabetes, cancer, renal and cardiac failure and in aging-sarcopenia. In these catabolic conditions the mitochondrial content, morphology and function are greatly affected. The changes of mitochondrial network influence the production of reactive oxygen species (ROS that play an important role in muscle function. Moreover, dysfunctional mitochondria trigger catabolic signaling pathways which feed-forward to the nucleus to promote the activation of muscle atrophy. Exercise, on the other hand, improves mitochondrial function by activating mitochondrial biogenesis and mitophagy, possibly playing an important part in the beneficial effects of physical activity in several diseases. Optimised mitochondrial function is strictly maintained by the coordinated activation of different mitochondrial quality control pathways. In this review we outline the current knowledge linking mitochondria-dependent signaling pathways to muscle homeostasis in aging and disease and the resulting implications for the development of novel therapeutic approaches to prevent muscle loss.

  12. Quality assurance standards for purchasing and inventory control.

    Science.gov (United States)

    Soares, D P

    1985-03-01

    A process is described for quality assurance in pharmaceutical purchasing and inventory control. A quality assurance program should ensure that quality drugs are purchased at the lowest price, drug products are available when needed, the system is managed efficiently, internal controls are provided, drug products are stored under appropriate conditions, and laws, regulations, accreditation standards, and procedures are followed. To meet these objectives, product quality, vendor performance, the department's system of internal controls, purchasing data, and storage conditions should be monitored. A checklist for evaluating purchasing and inventory practices and a sample audit form listing quality assurance criteria, standards, procedures, and recommended actions are provided. A quality assurance program for pharmaceutical purchasing and inventory control should define institution-specific criteria and standards and use these standards for continual evaluation of all aspects of the purchasing and inventory control system. Documentation of quality assurance activities should be provided for use by the purchasing department, hospital administration, and regulatory bodies. PMID:3985026

  13. Retroperitoneoscopic renal biopsy in children

    Directory of Open Access Journals (Sweden)

    Carlos M. Jesus

    2007-08-01

    Full Text Available OBJECTIVE: We present our experience in a series of 17 consecutive pediatric patients submitted to retroperitoneal laparoscopic renal biopsy. MATERIALS AND METHODS: Retroperitoneal laparoscopic renal biopsy (LRB was performed in 5 boys and 12 girls. Mean age was 8.1 years and age range from 2 to 12. Two or three trocars were used to expose the inferior pole of the kidney, remove enough cortical parenchymal specimen and fulgurate the biopsy site. Assessment included surgical time, estimated blood loss, hospitalization period, analgesia requirements, complications and number of glomeruli present in the specimen. RESULTS: LRB was successfully performed in all 15 patients (88%. In two cases, LRB was not possible to be performed. One patient was converted to a transperitoneal laparoscopy due to tear in the peritoneum. The other patient had had previous abdominal surgery and, during retroperitoneal balloon dilation, the peritoneum was opened and the open biopsy was performed. A third patient had postoperatively a perirenal hematoma, which was solved spontaneously. Complication rate was 17.6% (3/17 cases. Mean operative time was 65 minutes, while mean estimated blood loss was 52 mL, mean hospital stay was 2.2 days and mean analgesic requirement was 100 mg of tramadol. The mean number of glomeruli present in the specimen was 60. CONCLUSION: Retroperitoneal laparoscopic renal biopsy in children is a simple, safe. Bleeding is still the most common complication. However, direct vision usually allows a safe control of this drawback. In our institution, laparoscopic approach is the chosen procedure in pediatric patients older than one - year - old.

  14. Thyroid gland biopsy (image)

    Science.gov (United States)

    ... a sample of cells is needed from the thyroid gland a fine needle biopsy can be performed. During ... procedure, a skinny needle is inserted into the thyroid gland, and a sample of thyroid cells and fluid ...

  15. Lung needle biopsy

    Science.gov (United States)

    ... if you have certain lung diseases such as emphysema. Usually, a collapsed lung after a biopsy does ... any type Bullae (enlarged alveoli that occur with emphysema) Cor pulmonale Cysts of the lung Pulmonary hypertension ...

  16. Quality control with R an ISO standards approach

    CERN Document Server

    Cano, Emilio L; Prieto Corcoba, Mariano

    2015-01-01

    Presenting a practitioner's guide to capabilities and best practices of quality control systems using the R programming language, this volume emphasizes accessibility and ease-of-use through detailed explanations of R code as well as standard statistical methodologies. In the interest of reaching the widest possible audience of quality-control professionals and statisticians, examples throughout are structured to simplify complex equations and data structures, and to demonstrate their applications to quality control processes, such as ISO standards. The volume balances its treatment of key aspects of quality control, statistics, and programming in R, making the text accessible to beginners and expert quality control professionals alike. Several appendices serve as useful references for ISO standards and common tasks performed while applying quality control with R.

  17. Biopsy in Musculoskeletal Tumors

    Directory of Open Access Journals (Sweden)

    Mohammad Gharehdaghi

    2014-09-01

    Full Text Available Diagnosis of bone tumors is based on careful evaluation of clinical, imaging and a pathologic findings. So the biopsy of bone and soft tissue sarcomas is the final step in evaluation and a fundamental step in the diagnosis of the lesion. It should not be performed as a shortcut to diagnosis (1. The biopsy should be performed in order to confirm the diagnosis and differentiate among few diagnoses after careful staged studies. Real and artificial changes in imaging studies will be superimposed after performing biopsy, which may alter the interpretation if done after biopsy is taken (1. The correct management of a sarcoma depends on the accurate diagnosis. Inadequate, inapprppriate, or inaccurate non-representative biopsy leads to poorer outcome in terms of survivorship and limb salvage. An incorrect, unplanned incision and biopsy may unnecessarily contaminate uninvolved compartments which may convert a salvageable limb to amputation. Anatomic approach along with the proper biopsy techniques may lead to success or catastrophe. It is clear that in patients with inappropriate biopsy, the chance of the need to change the treatment to more radical than would originally be expected is significantly higher. Also it is more probable to need to  convert curative to palliative treatment and to require adjuvant radiotherapy in patients with inappropriate biopsies. Patients with sarcoma are best served by early referral to a specialized center where staged investigations and biopsy can be performed with minimal morbidity (3. Open biopsy is still considered the gold standard; however, recent studies suggest comparable results with percutaneous core needle biopsy. Our study on 103 consecutive CNB and open biopsy showed comparable results as well. Surgeons need to answer to two questions prior to performing a biopsy: 1-          Where is the best part of the lesion to be biopsied? 2-          What is the safest route without contaminating

  18. 42 CFR 84.256 - Quality control requirements.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Quality control requirements. 84.256 Section 84.256... § 84.256 Quality control requirements. (a) In addition to the construction and performance requirements specified in §§ 84.251, 84.252, 84.253, 84.254, and 84.255, the quality control requirements in...

  19. Corpus vitreum, retina og chorioidea biopsi

    DEFF Research Database (Denmark)

    Scherfig, Erik Christian Høegh

    2002-01-01

    oftalmology, biopsy, choroid, corpus vitreum, retina, malignant melanoma, biopsy technic, retinoblastoma......oftalmology, biopsy, choroid, corpus vitreum, retina, malignant melanoma, biopsy technic, retinoblastoma...

  20. Auditor independence, audit committee quality and internal control weaknesses

    OpenAIRE

    Sorinel Domnișoru; Sorin-Sandu Vînătoru

    2008-01-01

    In this paper we investigate the relation between auditor independence, audit committee quality and the disclosure of internal control weaknesses. We begin with a sample of firms with internal control weaknesses and, based on industry, size, and performance, match these firms to a sample of control firms without internal control weaknesses. Our conditional logit analyses indicate that a relation exists between audit committee quality, auditor independence, and internal control weaknesses. Fir...

  1. Quality-Driven Synthesis and Optimization of Embedded Control Systems

    OpenAIRE

    Samii, Soheil

    2011-01-01

    This thesis addresses several synthesis and optimization issues for embedded control systems. Examples of such systems are automotive and avionics systems in which physical processes are controlled by embedded computers through sensor and actuator interfaces. The execution of multiple control applications, spanning several computation and communication components, leads to a complex temporal behavior that affects control quality. The relationship between system timing and control quality is a...

  2. Evaluation of a Biopsy Gun for Guided Biopsy of Impalpable Liver Lesions Using Intraoperative Utrasound

    OpenAIRE

    Charnley, R. M.; Sheffield, J P; Hardcastle, J. D.

    1990-01-01

    A biopsy gun which can be operated by one hand has been evaluated at post-mortem to determine its accuracy in biopsying impalpable lesions within the liver under intraoperative ultrasound control. Of 20 impalpable metastases identified positive histology was obtained in 90% demonstrating that this technique is of value in identifying and localising metastases in the liver.

  3. Quality assurance in food irradiation with emphasis on process control

    International Nuclear Information System (INIS)

    Process control is an essential component of quality assurance in food irradiation. This paper discusses the key elements of process control of gamma and electron beam irradiation of foods. They include irradiated product investigation and qualification, irradiator qualification (commissioning), dosimetry including calibration and dose-mapping, licensing documentation and inspection, and, details of routine process control. Radiation process control combined with incoming product quality control and outgoing (processed) product handling, etc., control constitute the essence of overall quality assurance in food irradiation. (author). 11 refs

  4. Methods for Prostate Biopsy

    Directory of Open Access Journals (Sweden)

    M. Ghafoori

    2008-01-01

    Full Text Available Prostate cancer is currently the most prevalent form of cancer in men and the second leading cause of can-cer death in the United States, and the third most common cancer in men worldwide. Increasing mor-tality rates due to prostate carcinoma have been ob-served worldwide. This disease usually progresses im-perceptibly; thus, patients are unlikely to seek medi-cal help during the early stages. For these reasons, screening programs aimed at early detection have been developed. The prostate-specific antigen (PSA test is among the best screening tools available in medicine today and is recognized as the best marker for its early detection. Prostate cancers detected by DRE method alone are clinically localized only 50% to 60% of the time, whereas PSA-detected tumors are clinically localized 90% of the time and pathologi-cally confined to the prostate as determined at prostatectomy about two thirds of the time. Recently, the detection of localized prostate cancers has improved, owing to the development of various new biopsy methods. However, a standard biopsy method, including number of cores, has not yet been established at present. When screening results indi-cate the possibility of prostate cancer, a pathologic diagnosis may be pursued by ultrasound guided trans-rectal needle biopsy. Prostate biopsy is usually ad-vised if serum PSA is >4 ng/mL, and this procedure remains the gold standard for prostate cancer diagno-sis. Fine needle biopsy is less painful than core bi-opsy, but also less diagnostically accurate. Systematic biopsy protocols: In 1989, Hodge et al. coined the sextant biopsy method that is still the standard of reference in prostate cancer detection. The prostate is bilaterally divided into three regions (apex, midgland, and base, all of which are system-atically biopsied once. Although Hodge et al. first proposed sextant biopsy under transrectal ultrasound guidance, some recent reports have indicated that systematic sextant biopsy

  5. Quality control by a mobile molecular workshop: quality versus quantity

    CERN Document Server

    Sharma, Ajeet K

    2010-01-01

    Ribosome is a molecular machine that moves on a mRNA track while, simultaneously, polymerizing a protein using the mRNA also as the corresponding template. We introduce quantitative measures of its performance which characterize, for example, the speed and fidelity of the template-dictated polymerization. We also define two different measures of efficiency and strength of mechano-chemical coupling of this molecular machine. We calculate all these quantities analytically. Some of these quantities show apparently counterintuitive trends of variation with the quality of kinetic proofreading. We interpret the origin of these trends. We suggest new experiments for testing some of the ideas presented here.

  6. Food and Nutrition Services Quality Control Management Program.

    Science.gov (United States)

    Wimsatt-Fraim, Teresa S.

    A program was conducted to improve the quality of food service through the training of 44 food and nutrition service employees in a 200-bed hospital. A 12-week quality control program was implemented to address four key areas: food temperatures, food accuracy, food quality, and dietary personnel. Learning strategies, emphasizing critical thinking…

  7. Teaching Quality Control with Chocolate Chip Cookies

    Science.gov (United States)

    Baker, Ardith

    2014-01-01

    Chocolate chip cookies are used to illustrate the importance and effectiveness of control charts in Statistical Process Control. By counting the number of chocolate chips, creating the spreadsheet, calculating the control limits and graphing the control charts, the student becomes actively engaged in the learning process. In addition, examining…

  8. Magnetotelluric quality control study and calibration survey

    International Nuclear Information System (INIS)

    We have performed a managetotelluric study in order to evaluate the data quality and reliability of magnetotelluric information obtained for Rockwell Hanford Operations by two sub-contractors. The motivation for performing this study resulted from: relatively poor and variable data quality and some major disagreements between the results obtained in these two surveys. Geotronics' task was to perform an analysis based on the material included in these survey reports and other available information

  9. 10 CFR 26.167 - Quality assurance and quality control.

    Science.gov (United States)

    2010-01-01

    ... each test. Validation of procedures must document that carryover does not affect the donor's specimen...); and (v) At least one control that appears to be a donor specimen to the laboratory analysts. (4) A... determined and that corrective action is taken to preclude repetition. The identification of the...

  10. Use of a newly developed piezoelectrically driven drilling machine for MR-guided bone biopsies

    International Nuclear Information System (INIS)

    Purpose: Development and clinical testing of an MR-compatible bone biopsy system, to enable the sample collection from osteosclerotic or subcortical lesions for histological investigation under MR control. Materials and Methods: A piezoelectrically driven drilling machine was constructed and tested in connection with an MR-compatible bone biopsy set in a vertical open MR scanner (0.5 T) on a phantom and 10 patients with ambiguous bone lesions. Images were obtained using T1-weighted spin-echo sequences and, in case of real-time imaging, a fast spoiled gradient-echo sequence. Results: The influence of the enabled motor (RF-interference) leads to a reduction of the signal to noise ratio of the images, but can be minimised by appropriate measures. The observed slight field distorsions do not affect the image quality during real time acquisition in a substantial manner. No complications occurred. The extracted biopsy material was sufficient and of good quality. Conclusions: In spite of slightly restricted image quality, the described drilling machine combined with the bone biopsy set is well suited for MR-guided bone biopsies, which require the application of a motor driven drill. Its application within an interventional MR scanner is safe and its handling simple and manageable. (orig.)

  11. Negative Biopsy after Referral for Biopsy-Proven Gastric Cancer

    OpenAIRE

    Tae, Chung Hyun; Lee, Jun Haeng; Min, Byung-Hoon; Kim, Kyoung-Mee; Rhee, Poong-Lyul; Kim, Jae J

    2016-01-01

    Background/Aims Repeat endoscopy with biopsy is often performed in patients with previously diagnosed gastric cancer to determine further treatment plans. However, biopsy results may differ from the original pathologic report. We reviewed patients who had a negative biopsy after referral for gastric cancer. Methods A total of 116 patients with negative biopsy results after referral for biopsy-proven gastric cancer were enrolled. Outside pathology slides were reviewed. Images of the first and ...

  12. Joint Determination of Optimal Inventory and Quality Control Policy

    OpenAIRE

    Michael H. Peters; Helmut Schneider; Kwei Tang

    1988-01-01

    Typically the operating policy for the inventory control system for a commodity is developed independent of the operating policy for the quality control system for that commodity and vice versa. In many circumstances, these systems are dependent on one another. A cost model that combines a fixed order quantity inventory control system with a Bayesian quality control system for a lot-by-lot attribute acceptance sampling plan is presented along with an algorithm to obtain the operating paramete...

  13. Quality control protocols for radiodiagnosis agents and radiopharmaceuticals

    International Nuclear Information System (INIS)

    Based on the compilation of pharmacopoeia methods, literature, manuals and other information developed in our laboratory, protocols have been prepared to carry out quality controls for radiodiagnosis agents (RDA), better known as kits and RDA labelled with Tc99m. Quality control protocols cover physicochemical and biological controls. Physicochemical controls described for RDA include physical characteristics, particle size and number, pH, chemical identification, humidity, tin II; whereas biological controls include sterility, acute toxicity and bacterial endotoxin determination (LAL). Physicochemical controls described for radiopharmaceuticals labelled with Tc99m are pH and radiochemical purity; while biological distribution is described as a biological control

  14. Chemical and physical quality control of the HIPPURAN-131I

    International Nuclear Information System (INIS)

    Some physico-chemical methods for analytical control of Hippuran-131I are compared. The most convenient to applicate in hospitals and in more specialized quality control laboratories are recommended. The quality of Hippuran-131I produced by ISOTOP (USSR) is also evaluated. The product met the requirement of the International Pharmacopeia

  15. 75 FR 41874 - Quality Control for Rental Assistance Subsidy Determinations

    Science.gov (United States)

    2010-07-19

    ... URBAN DEVELOPMENT Quality Control for Rental Assistance Subsidy Determinations AGENCY: Office of the.... This notice also lists the following information: Title of Proposal: Quality Control for Rental... agency's estimate of the burden of the proposed collection of information; (3) Enhance the...

  16. Artificial Intelligence Approach to Support Statistical Quality Control Teaching

    Science.gov (United States)

    Reis, Marcelo Menezes; Paladini, Edson Pacheco; Khator, Suresh; Sommer, Willy Arno

    2006-01-01

    Statistical quality control--SQC (consisting of Statistical Process Control, Process Capability Studies, Acceptance Sampling and Design of Experiments) is a very important tool to obtain, maintain and improve the Quality level of goods and services produced by an organization. Despite its importance, and the fact that it is taught in technical and…

  17. Quality control system response to stochastic growth of amyloid fibrils

    DEFF Research Database (Denmark)

    Pigolotti, Simone; Lizana, Ludvig; Otzen, Daniel;

    2013-01-01

    We introduce a stochastic model describing aggregation of misfolded proteins and degradation by the protein quality control system in a single cell. Aggregate growth is contrasted by the cell quality control system, that attacks them at different stages of the growth process, with an efficiency t...

  18. 46 CFR 164.019-13 - Production quality control requirements.

    Science.gov (United States)

    2010-10-01

    ... components shall supplement its procedures for assuring production quality control with a program of... and a program for maintaining production and test equipment. (e) Responsibilities; recognized... 46 Shipping 6 2010-10-01 2010-10-01 false Production quality control requirements....

  19. Safety of timber: An analysis of quality control options

    NARCIS (Netherlands)

    Kovryga, A.; Stapel, P.; Van de Kuilen, J.W.G.

    2014-01-01

    The quality assurance of timber properties is important for the safety of timber structures. In the current study, the quality control options of timber are analysed under the prism of the different growth regions. Therefore, these options - machine and output control - are simulated in accordance w

  20. Quality control of geological voxel models using experts' gaze

    NARCIS (Netherlands)

    Maanen, P.P. van; Busschers, F.S.; Brouwer, A.M.; Meulen, M.J. van der; Erp, J.B.F. van

    2015-01-01

    Due to an expected increase in geological voxel model data-flow and user demands, the development of improved quality control for such models is crucial. This study explores the potential of a new type of quality control that improves the detection of errors by just using gaze behavior of 12 geologi

  1. Electronic quality control on dental x-rays equipment

    International Nuclear Information System (INIS)

    A brief description of dental x-ray equipment is done. The non-invasive quality control is treated as than the responsibilities from the dentists to the patient and the equipment. A propose for quality control for dental x-ray equipment, film and developer is include

  2. Procedures for quality control of thermoluminescent dosimetry laboratory

    International Nuclear Information System (INIS)

    In order to assurance the results accuracy of a thermoluminescence dosimetry laboratory it is necessary a quality control program. For a laboratory in operation, without a structured program, the quality control should be started for documentation of its technical and administrative procedures. It is presented a proposal with the essential procedures to carry out this program. (author)

  3. Internal quality control in serological tests for syphilis.

    OpenAIRE

    Wasley, G. D.

    1985-01-01

    The importance of syphilis serological tests demands that laboratory reports are reliable. Internal quality control applied to the organisation of a syphilis serology service improves laboratory bench performance and reporting. Described here are internal quality control procedures of a department that serves a genitourinary medicine clinic and conducts 70 000 tests a year to investigate for syphilis.

  4. Importance of Local Control in Early-Stage Prostate Cancer: Outcomes of Patients With Positive Post-Radiation Therapy Biopsy Results Treated in RTOG 9408

    Energy Technology Data Exchange (ETDEWEB)

    Krauss, Daniel J., E-mail: dkrauss@beaumont.edu [Department of Radiation Oncology, Oakland University William Beaumont School of Medicine, Royal Oak, Michigan (United States); Hu, Chen [NRG Statistics and Data Management Center, Philadelphia, Pennsylvania (United States); Bahary, Jean-Paul [Centre Hospitalier de l' Université de Montréal-Notre Dame, Montreal, Quebec (Canada); Souhami, Luis [McGill University, Montreal, Quebec (Canada); Gore, Elizabeth M. [Medical College of Wisconsin, Milwaukee, Wisconsin (United States); Chafe, Susan Maria Jacinta [Cross Cancer Institute, Edmonton, Alberta (Canada); Leibenhaut, Mark H. [Sutter General Hospital, Sacramento, California (United States); Narayan, Samir [Michigan Cancer Research Consortium CCOP (United States); Torres-Roca, Javier [H. Lee Moffitt Cancer Center and Research Institute, Tampa, Florida (United States); Michalski, Jeff [Washington University, St. Louis, Missouri (United States); Zeitzer, Kenneth L. [Albert Einstein Medical Center, Bronx, New York, New York (United States); Donavanik, Viroon [Christiana Care Health Services Inc CCOP, Newark, Delaware (United States); Sandler, Howard [Cedars-Sinai Medical Center, Los Angeles, California (United States); McGowan, David G. [Cross Cancer Institute, Edmonton, Alberta (Canada); Jones, Christopher U. [Sutter General Hospital, Sacramento, California (United States); Shipley, William U. [Dana-Farber Cancer Institute, Boston, Massachusetts (United States)

    2015-07-15

    Purpose: The purpose of this study was to assess the association between positive post-radiation therapy (RT) biopsy results and subsequent clinical outcomes in males with localized prostate cancer. Methods and Materials: Radiation Therapy Oncology Group study 94-08 analyzed 1979 males with prostate cancer, stage T1b-T2b and prostate-specific antigen concentrations of ≤20 ng/dL, to investigate whether 4 months of total androgen suppression (TAS) added to RT improved survival compared to RT alone. Patients randomized to receive TAS received flutamide with luteinizing hormone releasing hormone (LHRH) agonist. According to protocol, patients without evidence of clinical recurrence or initiation of additional endocrine therapy underwent repeat prostate biopsy 2 years after RT completion. Statistical analysis was performed to evaluate the impact of positive post-RT biopsy results on clinical outcomes. Results: A total of 831 patients underwent post-RT biopsy, 398 were treated with RT alone and 433 with RT plus TAS. Patients with positive post-RT biopsy results had higher rates of biochemical failure (hazard ratio [HR] = 1.7; 95% confidence interval [CI] = 1.3-2.1) and distant metastasis (HR = 2.4; 95% CI = 1.3-4.4) and inferior disease-specific survival (HR = 3.8; 95% CI = 1.9-7.5). Positive biopsy results remained predictive of such outcomes after correction for potential confounders such as Gleason score, tumor stage, and TAS administration. Prior TAS therapy did not prevent elevated risk of adverse outcome in the setting of post-RT positive biopsy results. Patients with Gleason score ≥7 with a positive biopsy result additionally had inferior overall survival compared to those with a negative biopsy result (HR = 1.56; 95% CI = 1.04-2.35). Conclusions: Positive post-RT biopsy is associated with increased rates of distant metastases and inferior disease-specific survival in patients treated with definitive RT and was associated with inferior overall

  5. Contributions of CCLM to advances in quality control.

    Science.gov (United States)

    Kazmierczak, Steven C

    2013-01-01

    Abstract The discipline of laboratory medicine is relatively young when considered in the context of the history of medicine itself. The history of quality control, within the context of laboratory medicine, also enjoys a relatively brief, but rich history. Laboratory quality control continues to evolve along with advances in automation, measurement techniques and information technology. Clinical Chemistry and Laboratory Medicine (CCLM) has played a key role in helping disseminate information about the proper use and utility of quality control. Publication of important advances in quality control techniques and dissemination of guidelines concerned with laboratory quality control has undoubtedly helped readers of this journal keep up to date on the most recent developments in this field.

  6. How to set up and manage quality control and quality assurance

    NARCIS (Netherlands)

    Visschedijk, M.; Hendriks, R.; Nuyts, K.

    2005-01-01

    This document provides a general introduction to clarify the differences between quality control (QC) and quality assurance (QA). In addition it serves as a starting point for implementing a quality system approach within an organization. The paper offers practical guidance to the implementation of

  7. PERCUTANEOUS PLEURAL BIOPSY

    Directory of Open Access Journals (Sweden)

    M. Bahadori

    1966-01-01

    Full Text Available I have carried out 22 biopsies in 20 Patients, in fifteen I used a Vim _ Silverman Needle, and in the remainder a curetting type Needle, In 12 cases (60% the diagnosis that was made; in 3 cases, inadequate tissue, was obtained; in two cases a fibromuscular tissue, in one case a fatty tissue and in one case the specimen was of hepatic tissue. Even with the small biopsy specimen obtained with the Needle it is easy to recognize malignant tissue if present.

  8. Greenhouse climate control affects postharvest tomato quality

    NARCIS (Netherlands)

    Farneti, B.; Schouten, R.E.; Qian, T.; Dieleman, J.A.; Tijskens, L.M.M.; Woltering, E.J.

    2013-01-01

    In this study, important quality properties such as firmness, sugar and acid levels were measured and analysed in tomatoes harvested from three greenhouses during a five month period and stored at 16 degrees C for over 20 days. Tomatoes were harvested from three identical, neighbouring, greenhouses

  9. PROCESS VARIABILITY REDUCTION THROUGH STATISTICAL PROCESS CONTROL FOR QUALITY IMPROVEMENT

    Directory of Open Access Journals (Sweden)

    B.P. Mahesh

    2010-09-01

    Full Text Available Quality has become one of the most important customer decision factors in the selection among the competing product and services. Consequently, understanding and improving quality is a key factor leading to business success, growth and an enhanced competitive position. Hence quality improvement program should be an integral part of the overall business strategy. According to TQM, the effective way to improve the Quality of the product or service is to improve the process used to build the product. Hence, TQM focuses on process, rather than results as the results are driven by the processes. Many techniques are available for quality improvement. Statistical Process Control (SPC is one such TQM technique which is widely accepted for analyzing quality problems and improving the performance of the production process. This article illustrates the step by step procedure adopted at a soap manufacturing company to improve the Quality by reducing process variability using Statistical Process Control.

  10. NIF Projects Controls and Information Systems Software Quality Assurance Plan

    International Nuclear Information System (INIS)

    Quality achievement for the National Ignition Facility (NIF) and the National Ignition Campaign (NIC) is the responsibility of the NIF Projects line organization as described in the NIF and Photon Science Directorate Quality Assurance Plan (NIF QA Plan). This Software Quality Assurance Plan (SQAP) is subordinate to the NIF QA Plan and establishes quality assurance (QA) activities for the software subsystems within Controls and Information Systems (CIS). This SQAP implements an activity level software quality assurance plan for NIF Projects as required by the LLNL Institutional Software Quality Assurance Program (ISQAP). Planned QA activities help achieve, assess, and maintain appropriate quality of software developed and/or acquired for control systems, shot data systems, laser performance modeling systems, business applications, industrial control and safety systems, and information technology systems. The objective of this SQAP is to ensure that appropriate controls are developed and implemented for management planning, work execution, and quality assessment of the CIS organization's software activities. The CIS line organization places special QA emphasis on rigorous configuration control, change management, testing, and issue tracking to help achieve its quality goals.

  11. NIF Projects Controls and Information Systems Software Quality Assurance Plan

    Energy Technology Data Exchange (ETDEWEB)

    Fishler, B

    2011-03-18

    Quality achievement for the National Ignition Facility (NIF) and the National Ignition Campaign (NIC) is the responsibility of the NIF Projects line organization as described in the NIF and Photon Science Directorate Quality Assurance Plan (NIF QA Plan). This Software Quality Assurance Plan (SQAP) is subordinate to the NIF QA Plan and establishes quality assurance (QA) activities for the software subsystems within Controls and Information Systems (CIS). This SQAP implements an activity level software quality assurance plan for NIF Projects as required by the LLNL Institutional Software Quality Assurance Program (ISQAP). Planned QA activities help achieve, assess, and maintain appropriate quality of software developed and/or acquired for control systems, shot data systems, laser performance modeling systems, business applications, industrial control and safety systems, and information technology systems. The objective of this SQAP is to ensure that appropriate controls are developed and implemented for management planning, work execution, and quality assessment of the CIS organization's software activities. The CIS line organization places special QA emphasis on rigorous configuration control, change management, testing, and issue tracking to help achieve its quality goals.

  12. Methodical Grounds of Managing the Product Quality Control

    Directory of Open Access Journals (Sweden)

    Shapoval Olena A.

    2014-01-01

    Full Text Available The article analyses the modern state of products quality control management. It justifies a necessity of organisation of the quality control system under conditions of uninterrupted flow line production. It reveals problems connected with a low level of the products quality control management. It forms a set of factors of internal and external environments, which should be taken into account in the process of selection of a type of managerial actions by the products quality control. It considers specific features of identification of the most important factors at an enterprise on the basis of use of the matrix of strategic SWOT analysis. It offers a procedure of identification of a general assessment of factors of influence. It analyses a mechanism of use of main conceptual models, which reflect the system nature of quality management in an organisation – quality pyramids and quality loops. It proves a necessity of application of a principally new scheme of relations between the customer and enterprise, which envisages that requirements of the quality management system focus not on control and screening of semi-finished products, but on creation of conditions that exclude rejects. It considers the role of ISO 9000 in the system of quality management, which recommend the customers to make a preliminary assessment of activity of the producing enterprise.

  13. Ultrasound- and MRI-Guided Prostate Biopsy

    Science.gov (United States)

    ... Index A-Z Ultrasound- and MRI-Guided Prostate Biopsy Ultrasound- and MRI-guided prostate biopsy uses imaging ... Biopsy? What is Ultrasound- and MRI-guided Prostate Biopsy? Ultrasound- and MRI-guided prostate biopsies are performed ...

  14. Quality control of rain data used for urban runoff systems

    DEFF Research Database (Denmark)

    Jørgensen, H. K.; Rosenørn, S.; Madsen, Henrik;

    1998-01-01

    for collection and quality control of rain data from a network of tipping bucket rain gauges in Denmark carried out by the Danish Meteorological Institute. During rain, the RIMCO gauge counts the number of tips teach of 0.2 mm of precipitation) every minute, The quality control of the rain data includes......When improving software packages such as MOUSE and SAMBA for designing sewers and storage basins, and simulating overflows and flooding the quality of the input becomes important. The essential input to these modelling tools are the historical rain series. This paper presents the procedures...... Hellmann gauges. Shortcomings and improvements of the quality control are discussed. Although, it is possible to improve the efficiency of the quality control, long term corrections will always be necessary. (C) 1998 Published by Elsevier Science Ltd. All rights reserved....

  15. Quality Management of CERN Vacuum Controls

    CERN Document Server

    Antoniotti, F; Fortescue-Beck, E; Gama, J; Gomes, P; Le Roux, P; Pereira, H F; Pigny, G

    2014-01-01

    The vacuum controls Section (TE-VSC-ICM) is in charge of the monitoring, maintenance and consolidation of the control systems of all accelerators and detectors in CERN; this represents 6 000 instruments distributed along 128 km of vacuum chambers, often of heterogeneous architectures and of diverse

  16. Totally Carrying out Zero Defects Quality Control

    Institute of Scientific and Technical Information of China (English)

    ZhangQingwei; CASCPresident

    2004-01-01

    Editorial note: On March 22,1992 the launch of LM-2E launch vehicle with an Australian satellite was terminated. A piece of 0.15 milligram aluminum redundance led to the malfunction of the program distributor, which caused the emergency cutoff after 7 seconds of the ignition of the rocket. To bear in mind the painful lesson, China Aerospace Corporation set out March 22 to be “Space Quality Day” in 1994.

  17. Justification and quality control in radiodiagnostics

    International Nuclear Information System (INIS)

    The role of the radiodiagnostician in justification of x-ray examination is discussed. Under the final responsibility of the radio-diagnostician the more common examinations are performed by laboratory assistants. A justification judgement before by the radio-diagnostician does not take place. In case of complicated examinations often previous consultation between radio-diagnostician and clinician is necessary. The fast development of new techniques like CT, echography and MRI has as result that the modern radio-diagnostician develops more and more into a imaging-specialist. In the consultation with the clinician he advises about the optimal diagnostics for a certain patient, taking optimally into account the risks of x-radiation. The justifying role of the radio-diagnostician depends further upon the relation with the requiring physician. In general the inter-collegial consultation is assumed to be sufficient within the hospitals, however the feedback to general practitioners seems to be improvable in some cases. With regard to quality assurance it is remarked that the quality of the examination may not be endangered by a too strong emphasis upon radiation reduction. Aspects like education level, protocol learning, dose limits, degressive tariffs, information-transfer, radiation passport, analysis between 'blue' ton, centralization of x-ray examination and quality of apparatus, are discussed. From the Government primarily a constraint setting policy is expected, in which rule-giving with respect to quality of education and apparatus is highly important. A stimulation of inter-collegial consulting may be expected, in particular in financial sense. A permission policy has to be managed, which ensures centralization of apparatus and centrally performance of x-ray examination as much as possible. Finally warning is given for the effects of excessive fear for radiation which causes refraining of medical necessary examination. The various risk have to be weighed up

  18. Optimizing prostate biopsy for repeat transrectal prostate biopsies patients

    Institute of Scientific and Technical Information of China (English)

    Xiaojun Deng; Jianwei Cao; Feng Liu; Weifeng Wang; Jidong Hao; Jiansheng Wan; Hui Liu

    2014-01-01

    Objective:Diagnosis of patients with negative prostate biopsy and persistent suspicion of prostate cancer re-mains a serious problem. In this study, we investigated the application of optimizing prostate biopsy for patients who need repeat prostate biopsy. Methods:In this prospective, non-randomized phase-I clinical trial, the prostate cancer detection rate of initial detection scheme was compared with optimizing prostate biopsy scheme. The number of punctures of initial detection scheme was the same as that of optimizing prostate biopsy scheme. The puncture direction of optimizing prostate biopsy was a 45° angle to the sagittal plane from front, middle, and back. The two cores from each lateral lobe were horizontal y inwardly inclined 45°. Results:A total of 45 patients with initial negative biopsy for cancer were received the optimizing prostate biopsy scheme. The cancer detection rate was 17.8%(8/45), and prostate intraepithelial neoplasm (PIN) was 6.7%(3/45). The pa-tients receiving repeat transrectal prostate biopsies were pathological y diagnosed as lower Gleason grade prostate cancers. Conclusion:The cancer detection rate of repeat biopsy prostate cancer is lower than that of initial biopsy. Our study showed that the optimizing prostate biopsy is important to improve the detection rate of repeat transrectal prostate biopsies patients.

  19. Quality control of CANDU6 fuel element in fabrication process

    International Nuclear Information System (INIS)

    To enhance the fine control over all aspects of the production process, improve product quality, fuel element fabrication process for CANDU6 quality process control activities carried out by professional technical and management technology combined mode, the quality of the fuel elements formed around CANDU6 weak links - - end plug , and brazing processes and procedures associated with this aspect of strict control, in improving staff quality consciousness, strengthening equipment maintenance, improved tooling, fixtures, optimization process test, strengthen supervision, fine inspection operations, timely delivery carry out aspects of the quality of information and concerns the production environment, etc., to find the problem from the improvement of product quality and factors affecting the source, and resolved to form the active control, comprehensive and systematic analysis of the problem of the quality management concepts, effectively reducing the end plug weld microstructure after the failure times and number of defects zirconium alloys brazed, improved product quality, and created economic benefits expressly provided, while staff quality consciousness and attention to detail, collaboration department, communication has been greatly improved and achieved very good management effectiveness. (authors)

  20. 前列腺尖部活检疼痛机制及预防的临床研究%Anal canal dentate line: the important anatomic maker in prostate apical biopsy pain control

    Institute of Scientific and Technical Information of China (English)

    高小峰; 周铁; 王林辉; 许传亮; 高旭; 孙颖浩

    2008-01-01

    目的 研究前列腺尖部活检疼痛的发生机理及预防方法. 方法 观察尖部活检时穿刺针的进针位置,设计2种方法来降低疼痛程度.设立3个研究组,应用视觉模拟评分(VAS)尺评估应用不同镇痛方法进行前列腺尖部活检时患者的疼痛程度.对照组:10例,直接进行活检.肛管局麻组:10例,插入直肠探头前行肛管局部麻醉,1%利多卡因10 ml从肛门口向肛管方向环绕腹侧半圈局部浸润麻醉肛管,然后再插入直肠超声探头进行活检.针刺痛觉测试组:15例,穿刺针轻轻接触直肠,以患者有无疼痛的自主感觉判断齿状线的位置(齿状线上方无痛觉,下方有痛觉),然后从齿状线的上方进针活检.3组患者均先行尖部活检,VAS评分结束后再行前列腺其他部位的活检.结果观察尖部活检引起患者剧痛时的进针点,发现其位于齿状线以下的肛管.尖部活检3组的疼痛评分分别为:对照组4.46±1.24,肛管局麻组1.84±0.78,针刺痛觉测试组1.98±0.67(P0.05).对照组与肛管局麻组各有1例术后肛周疼痛,针刺痛觉测试组1例术后发热38.4℃. 结论 前列腺尖部穿刺活检引起的疼痛主要由活检针刺穿齿状线以下的肛管皮肤引起.通过针刺痛觉测试从齿状线上方进针能显著减轻疼痛.肛管局部麻醉虽然能减轻活检时的疼痛,但由于麻醉本身即能引起患者明显疼痛,无益于改善患者整个穿刺过程的疼痛体验.%Objective To explore the causes of more frequently happened painful prostate biopsy at the prostatic apex rather than at other areas of the gland and develop maneuvers to avoid this painful apical prostate biopsy. Methods The prostate apical biopsy needle ptmeture sites in the rectum were recorded and accessed. Two maneuvers were developed to avoid the pain. There were 3 groups in this clinical trail. Ten patients in the control group were performed the apical biopsies routinely without any maneuver. Ten

  1. Web quality control for lectures: Supercourse and Amazon.com.

    Science.gov (United States)

    Linkov, Faina; LaPorte, Ronald; Lovalekar, Mita; Dodani, Sunita

    2005-12-01

    Peer review has been at the corner stone of quality control of the biomedical journals in the past 300 years. With the emergency of the Internet, new models of quality control and peer review are emerging. However, such models are poorly investigated. We would argue that the popular system of quality control used in Amazon.com offers a way to ensure continuous quality improvement in the area of research communications on the Internet. Such system is providing an interesting alternative to the traditional peer review approaches used in the biomedical journals and challenges the traditional paradigms of scientific publishing. This idea is being explored in the context of Supercourse, a library of 2,350 prevention lectures, shared for free by faculty members from over 150 countries. Supercourse is successfully utilizing quality control approaches that are similar to Amazon.com model. Clearly, the existing approaches and emerging alternatives for quality control in scientific communications needs to be assessed scientifically. Rapid explosion of internet technologies could be leveraged to produce better, more cost effective systems for quality control in the biomedical publications and across all sciences.

  2. VPLS Based Quality and Cost Control for Tennessee Eastman Process

    Institute of Scientific and Technical Information of China (English)

    宋凯; 王海清; 李平

    2005-01-01

    Product quality and operation cost control obtain increasing emphases in modern chemical system engineering. To improve the fault detection power of the partial least square (PLS) method for quality control, a new QRPV statistic is proposed in terms of the VP (variable importance in projection) indices of monitored process variables, which is significantly advanced over and different from the conventional Q statistic. QRPV is calculated only by the residuals of the remarkable process variables (RPVs). Therefore, it is the dominant relation between quality and RPV not all process variables (as in the case of the conventional PLS) that is monitored by this new VP-PLS (VPLS) method. The combination of QRPV and T2 statistics is applied to the quality and cost control of the Tennessee Eastman (TE) process, and weak faults can be detected as quickly as possible. Consequently, the product quality of TE process is guaranteed and operation costs are reduced.

  3. The CEA contribution to quality control

    International Nuclear Information System (INIS)

    The Commissariat a l'Energie Atomique has developed original methods and techniques for testing delicate components of the primary circuit of pressure water reactors. These techniques make use of a very wide range of non destructive testing methods: Eddy currents, particularly multiple frequencies, for testing steam generator tubes, gudgeon and other pins focused ultrasonics for testing all the welds of the reactor vessel and its cover plate, mixed welds of steam vessels and generators, low welds of the pressurizer and gudgeon pins from the inside. On site use is effected with specific machines intended either for inspecting the tube bundles of steam generators under the responsibility of INTERCONTROLE Co., or for the complete examination of the reactor vessel by mixed CEA/INTERCONTROLE crews under the responsibility of the CEA. All these operations are subjected to a programme of quality assurance that provides the guaranty of execution complying with the procedures in force

  4. Academic Quality Control in Nigerian Universities: Exploring Lecturers' Perceptions

    Science.gov (United States)

    Obiekezie, E. O.; Ejemot-Nwadiaro, R. I.; Essien, M. I.; Timothy, A. Essien

    2014-01-01

    The level of job performance, international comparability and competitiveness of Nigerian university graduates are burning issues. Consequently, the academic quality of Nigerian universities has come under severe criticism. Since university lecturers are key players in quality control in universities, this study explored their perceptions of…

  5. 21 CFR 211.22 - Responsibilities of quality control unit.

    Science.gov (United States)

    2010-04-01

    ..., closures, in-process materials, packaging material, labeling, and drug products, and the authority to..., closures, packaging materials, in-process materials, and drug products shall be available to the quality... 21 Food and Drugs 4 2010-04-01 2010-04-01 false Responsibilities of quality control unit....

  6. Quality Changes of Frozen Meat During Storage and Control Measures

    Institute of Scientific and Technical Information of China (English)

    DU Jiangping

    2010-01-01

    The frozen is a common method of meat storage, generally applications in meat industrial. However, the quality of meat still have taken place changes even in the low temperature, This article discussion on the changes of frozen meat quality during freezing storage, and give the corresponding control measures.

  7. Quality Assurance and Control in Laboratory using Neutron Activation Analysis

    International Nuclear Information System (INIS)

    In accordance with the increment of international trade associated with the worldwide globalization, the importance of quality assurance and control for the commodity produced from one's own country has been stressed. ISO (International Organization for Standards) defines quality control as 'the operational techniques and activities that are used to fulfill the requirements for quality'. Since 1996, the HANARO research reactor in the Korea Atomic Energy Research Institute has been operated thereafter initial critical operation on April 1995. Neutron activation analysis system and applied techniques which is one of a nuclear analytical technologies using reactor neutrons has been developed for user's supporting and the establishment of the quality system for a measurement and analysis, testing and inspection was implemented successfully. On the basis of the qualified NAA system, the test and measurement of more than 1500 samples which is requested from 30 organizations including industrial companies, universities and institutes carried out in NAA laboratory annually. Moreover, as the goal of mutual recognition agreement (MRA) which can be removed a technical barrier in international trade, the objectivity and the confidence of analytical quality in NAA laboratory became established through the installation of international accreditation system by implementing analytical quality system in accordance with international standards in 2001. The aim of the report was to summarize the technical management of introduction, methods and the results for a quality control and assurance which should be performed in NAA technique using the HANARO research reactor. The report will help building up effective quality control strategy in the future

  8. Forward SCT Module Assembly and Quality Control at IFIC Valencia

    CERN Document Server

    Mitsou, V A; Civera, J V; Costa, M J; Escobar, C; Fuster, J; García, C; García-Navarro, J E; González, F; González-Sevilla, S; Lacasta, C; Llosá, G; Martí i García, S; Miñano, M; Modesto, P; Nácher, J; Rodríguez-Oliete, R; Sánchez, F J; Sospedra, L; Strachko, V

    2007-01-01

    This note discusses the assembly and the quality control tests of 282 forward detector modules for the ATLAS Semiconductor Tracker assembled at the Instituto de Fisica Corpuscular (IFIC) in Valencia. The construction and testing procedures are outlined and the laboratory equipment is briefly described. Emphasis is given on the module quality achieved in terms of mechanical and electrical stability.

  9. Development of Quality Control Procedures for Lepidoptera

    Science.gov (United States)

    Lepidopteran species are among the most destructive insect pests throughout the world. The sterile insect technique (SIT), within an area-wide integrated pest management (AW-IPM) approach, has proven to be a valuable tactic for controlling and eradicating important moth pests. Improving laboratory...

  10. Descriptive study of the quality control in mammography; Estudio descriptivo del control de calidad en mamografia

    Energy Technology Data Exchange (ETDEWEB)

    Gaona, E.; Perdigon C, G.M.; Casian C, G.A.; Azorin N, J.; Diaz G, J.A.I.; Arreola, M. [UAM, Xochimilco 14000 Mexico D.F. (Mexico)

    2005-07-01

    The goal of mammography is to provide contrast between a lesion that is possible residing within the breast and normal surrounding tissue. Quality control is essential for maintaining the contrast imaging performance of a mammography system and incorporate tests that are relevant in that they are predictive of future degradation of contrast imaging performance. These tests will also be done at frequency that is high enough to intercept most drifts in quality imaging or performance before they become diagnostically significant. The quality control study has as objective to describe the results of the assessment of quality imaging elements (film optical density, contrast (density difference), uniformity, resolution and noise) of 62 mammography departments without quality control program and comparison these results with a mammography reference department with a quality control program. When comparing the results they allow seeing the clinical utility of to have a quality control program to reduce the errors of mammography interpretation. (Author)

  11. Recent advances in bone marrow biopsy pathology

    OpenAIRE

    van der Walt, Jon

    2009-01-01

    The second quarter of 2009 saw steady advances in bone marrow biopsy (BMB) pathology. The following publications are a personal selection of the highlights. Quality issues in diagnostic immunohistochemistry for BMB have largely been ignored in external quality assurance programmes, and this issue is highlighted. In other areas, publications reflecting advances in flow cytometry and aspirate morphology are discussed where translation to the BMB is possible. Classifications undergo constant cha...

  12. 14 CFR 145.211 - Quality control system.

    Science.gov (United States)

    2010-01-01

    ... contractors performs maintenance, preventive maintenance, or alterations. (b) Repair station personnel must follow the quality control system when performing maintenance, preventive maintenance, or alterations... maintenance, preventive maintenance, or alteration is performed; (iv) Establishing and maintaining...

  13. NOAA Ship Henry B. Bigelow Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Henry B. Bigelow Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic...

  14. Quality control system response to stochastic growth of amyloid fibrils.

    Science.gov (United States)

    Pigolotti, Simone; Lizana, Ludvig; Otzen, Daniel; Sneppen, Kim

    2013-05-01

    We introduce a stochastic model describing aggregation of misfolded proteins and degradation by the protein quality control system in a single cell. Aggregate growth is contrasted by the cell quality control system, that attacks them at different stages of the growth process, with an efficiency that decreases with their size. Model parameters are estimated from experimental data. Two qualitatively different behaviors emerge: a homeostatic state, where the quality control system is stable and aggregates of large sizes are not formed, and an oscillatory state, where the quality control system periodically breaks down, allowing for formation of large aggregates. We discuss how these periodic breakdowns may constitute a mechanism for the development of neurodegenerative diseases. PMID:23524241

  15. Performance Evaluation Model for Product Quality Control of Vegetable Cooperatives

    Directory of Open Access Journals (Sweden)

    Li Qin

    2013-08-01

    Full Text Available The purpose of this study is to investigate the product quality control performance of vegetable cooperatives in China, using Heilongjiang province as a case. This study applies fuzzy integral theory to develop a comprehensive evaluation model and analyzes the product quality control performance of the vegetable cooperatives. The results show that the performance of vegetable cooperatives in the production process is the highest. That is, vegetable cooperatives have important effect on the performance of product quality control mainly in the production process. Through the large-scale operation and the implementation of standardized production, vegetable cooperatives can effectively transform the decentralized production into the unified production. To exert the role of vegetable cooperatives in the product quality control, the incentive systems and the financial support policies should be improved and actively implement the brand strategy.

  16. NOAA Ship Bell M. Shimada Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Bell M. Shimada Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic...

  17. NOAA Ship Pisces Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Pisces Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  18. NOAA Ship David Starr Jordan Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship David Starr Jordan Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic...

  19. NOAA Ship Oscar Elton Sette Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Oscar Elton Sette Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic...

  20. Research Ship Nathaniel B. Palmer Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship Nathaniel B. Palmer Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and...

  1. Research Ship Aurora Australis Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship Aurora Australis Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic...

  2. Research Ship Southern Surveyor Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship Southern Surveyor Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and...

  3. Research Ship Knorr Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship Knorr Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  4. NOAA Ship Fairweather Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Fairweather Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  5. Research Ship Atlantic Explorer Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship Atlantic Explorer Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and...

  6. Research Ship Roger Revelle Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship Roger Revelle Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic...

  7. Research Ship T. G. Thompson Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship T. G. Thompson Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic...

  8. NOAA Ship Ronald Brown Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Ronald Brown Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  9. NOAA Ship Miller Freeman Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Miller Freeman Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic...

  10. NOAA Ship Gordon Gunter Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Gordon Gunter Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  11. Research Ship Atlantis Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship Atlantis Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  12. NOAA Ship Okeanos Explorer Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Okeanos Explorer Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic...

  13. Research Ship Robert Gordon Sproul Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship Robert Gordon Sproul Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and...

  14. NOAA Ship Ka'imimoana Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Ka'imimoana Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  15. Research Ship Laurence M. Gould Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship Laurence M. Gould Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and...

  16. Research Ship Oceanus Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship Oceanus Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  17. NOAA Ship Rainier Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Rainier Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  18. Research Ship Kilo Moana Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship Kilo Moana Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic...

  19. NOAA Ship Oscar Dyson Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Oscar Dyson Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  20. NOAA Ship Nancy Foster Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Nancy Foster Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  1. NOAA Ship Delaware II Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Delaware II Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  2. Research Ship New Horizon Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship New Horizon Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic...

  3. Research Ship Tangaroa Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship Tangaroa Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  4. NOAA Ship Hi'ialakai Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Hi'ialakai Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  5. Research Ship Healy Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship Healy Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  6. Research Ship Melville Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship Melville Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  7. NOAA Ship Oregon II Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Oregon II Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  8. Quality controls of radiopharmaceuticals used in nuclear medicine

    International Nuclear Information System (INIS)

    Chromatographic quality controls for Tc-99m; In-113m; I-131; Tl-201 and Ga-67 radiopharmaceuticals are described. Moreover, a chromatographic system which allows to separate different radiopharmaceuticals from In-113m is pointed out. (author)

  9. The role of admission control in assuring multiple services quality

    OpenAIRE

    Carvalho, Paulo; Lima, Solange; Freitas, Vasco

    2006-01-01

    Considering that network overprovisioning by itself is not always an attainable and everlasting solution, Admission Control (AC) mechanisms are recommended to keep network load controlled and assure the required service quality levels. This article debates the role of AC in multiservice IP networks, providing an overview and discussion of current and representative AC approaches, highlighting their main characteristics, pros and cons regarding the management of network services quality. I...

  10. Biofuel quality control by portable XRF-analyser

    OpenAIRE

    Golubev, Vitaly

    2015-01-01

    The objective of this thesis project was to find out feasibility of using a handheld XRF-analyser in solid biofuel quality control, particularly for recovered wood. Global biomass supply is estimated to grow rapidly, creating demand for automatic quality control systems. X-ray fluorescent technology brings about quick, accurate and non-destructive elemental analysis. Recovered wood fuel is challenging for combustion due to high levels of contaminants. During this work a list of challenging ch...

  11. Quality control of injection moulded micro mechanical parts

    DEFF Research Database (Denmark)

    Gasparin, Stefania; Tosello, Guido; Hansen, Hans Nørgaard;

    2009-01-01

    Quality control of micro components is an increasing challenge. Smaller mechanical parts are characterized by smaller tolerance to be verified. This paper focuses on the dimensional verification of micro injection moulded components selected from an industrial application. These parts are measured...... using an Optical Coordinate Measuring Machine (OCMM), which guarantees fast surface scans suitable for in line quality control. The uncertainty assessment of the measurements is calculated following the substitution method. To investigate the influence parameters in optical coordinate metrology two...

  12. Celiac Disease Diagnosis: Endoscopic Biopsy

    Science.gov (United States)

    ... This is done in a procedure called a biopsy: the physician eases a long, thin tube called ... the tissue using instruments passed through the endoscope. Biopsy of the small intestine is the only way ...

  13. Bone Marrow Aspiration and Biopsy

    Science.gov (United States)

    ... Global Sites Search Help? Bone Marrow Aspiration and Biopsy Share this page: Was this page helpful? Also ... Examination Formal name: Bone Marrow Aspiration; Bone Marrow Biopsy Related tests: Complete Blood Count ; WBC Differential ; Reticulocyte ...

  14. Gram stain of tissue biopsy

    Science.gov (United States)

    ... ency/article/003453.htm Gram stain of tissue biopsy To use the sharing features on this page, please enable JavaScript. Gram stain of tissue biopsy test involves using crystal violet stain to test ...

  15. Production control system specified quality sausage products

    Directory of Open Access Journals (Sweden)

    A. V. Tokarev

    2016-01-01

    Full Text Available The problem of management of production target in technological system of production of sausages of the set quality is considered in article. Decomposition of technological system is considered. Functions of management are allocated: formation of an optimum compounding of forcemeat, expert analysis of a compounding, laboratory analysis of a compounding and its statement. Information technology of interaction of these functions is offered. The mathematical problem definition of finding of an optimum compounding meat product with use of possible substitutes of ingredients is presented. This mathematical problem is a classical linear programming problem whose solution has the standard program. Since the manufacture of the finished product are various nonlinear effects are taken into account at the present time it is practically impossible, the methodology provided in this operation "Expert analysis of the formulation" and "Laboratory analysis of the finished product." An example of calculating the optimum alternative base recipe "Sausages “Viennese with cheese”" TS 9213-010-40155161-2002. For an alternative formulation demands were made at a cost of meat, the ingredient composition, as well as the final product organoleptic and physic-chemical indicators should comply with regulatory requirements "Sausages “Viennese with cheese”" TS 9213-010-40155161-2002. Indicator acid activity (pH calculated stuffing formulation should be in the range 6.0-6.3. As a partial replacement for the main raw material have been proposed acceptable substitutes. It was necessary to calculate on the basis of the formulation "Sausages “Viennese with cheese”" TS 9213-010-40155161-2002 optimal price and quality alternative formulation. As a result of depreciation of the value of alternative stuffing recipe was 14,5 % when all of the restrictions on the consumer properties. The proposed information technology implemented in the software package "Multi

  16. Quality control in computed tomography X-ray scanners

    International Nuclear Information System (INIS)

    Practical methods of estimating computed tomography X-ray scanner imaging performance treat the scanner as a black box, the measurements usually being non-invasive. The performance of individual components or groups of components within the system is not usually measured. The digital nature of the imaging process allows direct numerical assessment of the actual imaging parameters. This approach is used for type and acceptance testing as well as quality control, the type and acceptance tests providing the baseline for subsequent quality control measurements. The usual X-ray imaging parameters of noise, resolution and dose can all be used for quality control purposes, but the relative emphasis between these parameters will differ when compared with type or acceptance testing. Other simple measurements may be of equal use. All manufacturers suggest quality control protocols of varying complexity using a wide range of phantom designs. Where quality control is undertaken routinely, it is usually the manufacturer's protocols that are followed. It is pertinent to ask whether the quality control measurements currently suggested are necessary and/or sufficient. (author)

  17. Experience with ISO quality control in assisted reproductive technology.

    Science.gov (United States)

    Alper, Michael M

    2013-12-01

    Assisted reproductive technology (ART) programs are complex organizations requiring the integration of multiple disciplines. ISO 9001:2008 is a quality management system that is readily adaptable to an ART program. The value that ISO brings to the entire organization includes control of documents, clear delineation of responsibilities of staff members, documentation of the numerous processes and procedures, improvement in tracking and reducing errors, and overall better control of systems. A quality ART program sets quality objectives and monitors their progress. ISO provides a sense of transparency within the organization and clearer understanding of how service is provided to patients. Most importantly, ISO provides the framework to allow for continual improvement.

  18. Control measures for NDE and quality in project construction

    International Nuclear Information System (INIS)

    Projects are constructed with huge investments in money, time and effort and therefore it is essential that they perform well during the intended life period. The reliability so expected can only be ensured by achieving the desired quality in construction. Quality mainly depends upon the effective controlling of materials used in construction, work procedures adopted, personnel performing the important functions and work environment and also ensuring proper documentation. The above fact has been well recognized during construction of the Project at Kalpakkam under Dept. of Atomic Energy. The control measures which have been designed and successfully implemented for achieving the quality are presented. (author)

  19. Quality control of environmental radiation monitoring process

    International Nuclear Information System (INIS)

    This report summarizes for the period (January/2003 to September 2003) the analytical results of the Environmental Monitoring Program- Centro de Desenvolvimento da Tecnologia Nuclear - CDTN. A statistical treatment using control graphs for periodicity and tendency analysis according to temporal variation is also carried out. Moreover, a comparison of radioactive and stable elements concentrations with the derived and intake limits for ingestion and inhalation recommended by Comissao Nacional de Energia Nuclear, Fundacao Estatual do Meio Ambiente (FEAM) e Instituto Brasileiro do Meio Ambiente (IBAMA) is performed. The results are compliant with those recommended by the legislation. (author)

  20. The process of managerial control in quality improvement initiatives.

    Science.gov (United States)

    Slovensky, D J; Fottler, M D

    1994-11-01

    The fundamental intent of strategic management is to position an organization with in its market to exploit organizational competencies and strengths to gain competitive advantage. Competitive advantage may be achieved through such strategies as low cost, high quality, or unique services or products. For health care organizations accredited by the Joint Commission on Accreditation of Healthcare Organizations, continually improving both processes and outcomes of organizational performance--quality improvement--in all operational areas of the organization is a mandated strategy. Defining and measuring quality and controlling the quality improvement strategy remain problematic. The article discusses the nature and processes of managerial control, some potential measures of quality, and related information needs. PMID:10138526

  1. Research review: Indoor air quality control techniques

    International Nuclear Information System (INIS)

    Techniques for controlling the concentration of radon, formaldehyde, and combustion products in the indoor air are reviewed. The most effective techniques, which are generally based on limiting or reducing indoor pollutant source strengths, can decrease indoor pollutant concentrations by a factor of 3 to 10. Unless the initial ventilation rate is unusually low, it is difficult to reduce indoor pollutant concentrations more than approximately 50% by increasing the ventilation rate of an entire building. However, the efficiency of indoor pollutant control by ventilation can be enhanced through the use of local exhaust ventilation near concentrated sources of pollutants, by minimizing short circuiting of air from supply to exhaust when pollutant sources are dispersed and, in some situations, by promoting a displacement flow of air and pollutants toward the exhaust. Active air cleaning is also examined briefly. Filtration and electrostatic air cleaning for removal of particles from the indoor air are the most practical and effective currently available techniques of air cleaning. 49 refs., 7 figs

  2. [Our experience with outside laboratory quality control].

    Science.gov (United States)

    Dochev, D; Arakasheva, V; Nashkov, A; Tsachev, K

    1979-01-01

    The results from the national outside laboratory qualitative control of the clinical diagnostic laboratory investigations for the period September 1975 -- May 1977 were described. The following interlaboratory discrepancy was found on base of a systematic analysis of the data from the last two ring-like check-ups, November 1976 and May 1977, exressed by the variation coefficient (V.C. %); total protein, sodium, potassium and chlorides -- under 10%; cholesterol, urea and total fats -- between 10 and 20%; calcium, phosphorus, iron and creatinine -- over 20%. The highest per cent of admissible results are found with total protein -- to 85%; cholesterol -- to 70.38%; glucosa -- to 73.17%, urea -- to 69.23%, potassium -- to 59.46%, chlorides -- to 57.9%. With sodium, phosphorus, calcium, iron creatinine and uric acid the "admissibility" fluctuates about or under 50 per cent. The values of the qualitative-control indices discussed are comparable with the values obtained from them in the interlaboratory comparisons of other countries. PMID:494628

  3. Quality control of cemented waste forms

    Energy Technology Data Exchange (ETDEWEB)

    Slate, L.J.

    1994-12-31

    To insure that cemented radwaste remains immobilized after disposal, certain standards have been set in Europe by the Commission of the European Communities. One such standard is compressive strength. If the compressive strength can be predicted during the early curing stages, time and money can be saved and the quality of the final waste form guaranteed. It was determined that the 7- and 28-day compressive strength from radwaste cementation can be predicted during the mixing and early curing stages by at least three methods. The three that were studied were maturity, rheology, and impedance. Maturity is a temperature-to-time measurement, rheology is a shear stress-to-shear rate measurement, and impedance is the opposition offered to the flow of alternating current. These three methods were employed on five different cemented radwaste concentrations with three different water-to-cement ratios; thus, a total of 15 different mix designs were considered. The results showed that the impedance was the easiest to employ for an on-line process. The results of the impedance method showed a very good relationship between impedance and water-to-cement ratio; therefore, an accurate prediction of compressive strength of cemented radwaste can be drawn from this method. The results of the theology method were very good. The method showed that concrete conforms to the Bingham plastic rheologic model, and the theology method can be used to predict the compressive strength of cemented radwaste, but may be too cumbersome. The results of the maturity method were shown to be limited in accuracy for determining compressive strength.

  4. Quality control of cast brake discs

    Directory of Open Access Journals (Sweden)

    M. Stawarz

    2008-04-01

    Full Text Available The largest industrial application so far have the gray cast irons which are characterized by low tensile and bending strength, while at the same time they have good ultimate comprehensive strength. Additionally, the fatigue strength of gray cast irons is comparatively low and they are only to some extend sensitive for the surface waters effects. Cast iron is the material, which is comparatively easy to be processed, and for this reason – it is not expensive. Brake discs are exploited in particularly hard conditions. They must be resistant both against the thermal fatigue and abrasion wearing (at dry friction as well as against seizing, corrosion and mechanical load [1-3]. The gray cast iron, better than other materials, fulfills all the requirements necessary for making the material for the casts resistant against such tough conditions. This work reflects the researches aiming to define the quality of cast brake discs (ventilated and non-ventilated ones upon a period of their exploitation in real conditions. The following researches were performed: evaluations of the disc surface condition, measurement of disc thickness, examination of run – out flank and metallographic analysis. In order to more detailed recognition of mechanisms and reasons of brake discs wearing in real conditions, one should conduct additional examinations: computer analysis of the microstructure, chemical composition analysis, etc., as well as study of the technology of their production in foundries, where they are manufactured [4]. By obtaining the full set of the mentioned above data one can draw final conclusions and remove causes of possible defects.

  5. Quality control in diagnostic mammography: myths, realities and their importance in the final image quality

    International Nuclear Information System (INIS)

    Mammography is the most used tool for early detection of breast cancer and reduce mortality from this cause. Studies with ionizing radiation it is important that be justified and provide a quality image to make the diagnosis, to get more benefits and fewer risks. The problem is the difficult to obtain an image of the breast. Therefore, the commitment to quality mammography is to maximize the contrast, definition, resolution and reliability, thus minimizing noise and dose. A mammogram performed without quality don't detect early breast cancer and the study doesn't have sense. Quality mammography requires trained and experienced staff, modern equipment and in good conditions, correct positioning, right technical factors and appropriate viewing conditions. In addition, quality programs are required to reach to ensure quality, control in testing techniques and image quality. (author)

  6. Quality control and quality assurance of micromegas readout boards for the ATLAS New Small Wheel

    CERN Document Server

    Nanda, Amit

    2016-01-01

    The resistive anode boards of the Micromegas detectors for ATLAS NSW upgrade, will be produced in industries. The anode boards will be thoroughly evaluated at CERN following a detailed quality control and quality assurance (QA/QC) procedure. The report describes thoroughly the procedures and the design of a small QC tool for easier measurements of electrical properties of the readout boards.

  7. Image-Guided percutaneous biopsies with a biopsy gun

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kyung Hwan; Lim, Hyo Keun; Kim, Eun Ah; Yun, Ku Sub; Bae, Sang Hoo; Shin, Hyung Sik [Hallym University College of Medicine, Seoul (Korea, Republic of)

    1994-07-15

    We report the results of image-guided percutaneous biopsies with a biopsy gun and evaluate the clinical usefulness. One hundred and five biopsies under ultrasonographic or fluoroscopic guidance were performed. Various anatomic sites were targeted(liver; 50, chest; 22, kidney; 12, pancreas; 8, intraperitoeum; 7, retroperitoneum; ). Obtained tissue was diagnostic in 98 of the 105 biopsies(93%). In each instance, representative core tissue specimens were obtained. Evaluation of the core tissue by pathologist revealed consistent, uniform specimens that contained significant crush artifact in no case. Five biopsies yielded inadequate tissue which were too small for histopathologic interpretation or were composed of necrotic debris. Two biopsies yielded adequate tissues, but tissues were not of the target. The diagnoses were malignancy in 77 biopsies and benign disease in 21 biopsies. No complications other than mild, localized discomfort were encountered except a transient hemoptysis and pneumothorax which was observed in two patients. Cutting biopsy with a biopsy gun provided sufficient amount of target tissue for an accurate diagnosis of malignant and benign disease. It was a safe and useful procedure for percutaneous biopsy.

  8. Ultrasound-guided renal biopsy with automated biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Pil Yeob; Kwon, Jae Soo [Masan Samsung Hospital, Masan (Korea, Republic of)

    1998-01-01

    To elevate the diagnostic yield and complications of percutaneous ultrasound-guided renal biopsy using a biopsy gun in patients with diffuse renal disease. Using an automated biopsy gun mounted with a 16 G needle, biopsies were performed on 90 patients with diffuse renal disease. In a total of 95 biopsies, diagnostic yield, the mean number of glomeruli and frequency of complication were retrospectively analysed. Tissue adequate for histological diagnosis was obtained in 92 % of procedures. Mean glomerular yield was 8.3, and complications were seen in 26% of the procedures, 25 % of these were minor, and 1% were major. For the diagnosis of diffuse renal disease, ultrasound-guided percutaneous renal biopsy using an automated biopsy gun is accurate and safe. (author). 25 refs., 1 tab.

  9. Advanced methods of quality control in nuclear fuel fabrication

    International Nuclear Information System (INIS)

    Under pressure of current economic and electricity market situation utilities implement more demanding fuel utilization schemes including higher burn ups and thermal rates, longer fuel cycles and usage of Mo fuel. Therefore, fuel vendors have recently initiated new R and D programmes aimed at improving fuel quality, design and materials to produce robust and reliable fuel. In the beginning of commercial fuel fabrication, emphasis was given to advancements in Quality Control/Quality Assurance related mainly to product itself. During recent years, emphasis was transferred to improvements in process control and to implementation of overall Total Quality Management (TQM) programmes. In the area of fuel quality control, statistical control methods are now widely implemented replacing 100% inspection. This evolution, some practical examples and IAEA activities are described in the paper. The paper presents major findings of the latest IAEA Technical Meetings (TMs) and training courses in the area with emphasis on information received at the TM and training course held in 1999 and other latest publications to provide an overview of new developments in process/quality control, their implementation and results obtained including new approaches to QC

  10. 21 CFR 111.105 - What must quality control personnel do?

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 2 2010-04-01 2010-04-01 false What must quality control personnel do? 111.105... for Quality Control § 111.105 What must quality control personnel do? Quality control personnel must... manufacturing record. To do so, quality control personnel must perform operations that include: (a) Approving...

  11. Extraction of high-quality epidermal RNA after ammonium thiocyanate-induced dermo-epidermal separation of 4 mm human skin biopsies

    DEFF Research Database (Denmark)

    Clemmensen, Anders; Thomassen, Mads; Clemmensen, Ole;

    2009-01-01

    , and satisfactory amounts of high-quality RNA were obtained. Hybridization to Affymetrix HG_U133A 2.0 GeneChips showed that ammonium thiocyanate incubation had a minute effect on gene expression resulting in only one significantly downregulated gene (cystatin E/M). We conclude that epidermis can be reproducibly...

  12. Design and implementation of the STKOS quality-control system

    Institute of Scientific and Technical Information of China (English)

    Haixia; SUN; Danya; LI; Junlian; LI; Sizhu; WU; Tiejun; HU; Qing; QIAN

    2015-01-01

    Purpose: The aim of this study is to develop and implement a quality-control system to ensure authority control of the different knowledge units for the Scientific & Technological Knowledge Organization Systems(STKOS).Design/methodology/approach: First, we analyzed quality-control requirements based on the construction of the STKOS Metathesaurus. Then we designed a quality-control framework, the task management and transfer mechanism, and a service model. Afterwards, we carried out the experiments to check the rules and algorithms used in the system. Finally, the system was developed, and gradually optimized during its service.Findings: The quality-control system supports collaborative knowledge construction, as well as consistency checks of knowledge units with different granularity levels, including terminologies, relationships, and concepts. The system can be flexibly configured.Research limitations: The system is oriented to an English-language knowledge organization system, and may not perform well with Chinese-language systems and ontologies.Practical implications: The system can be used to support the construction of a single knowledge organization system, as well as data warehousing and interoperable knowledge organization systems. Originality/value: The STKOS quality-control system not only focuses on content building for the knowledge system, but also supports collaborative task management.

  13. Analytical techniques and quality control in biomedical trace element research

    DEFF Research Database (Denmark)

    Heydorn, K.

    1994-01-01

    The small number of analytical results in trace element research calls for special methods of quality control. It is shown that when the analytical methods are in statistical control, only small numbers of duplicate or replicate results are needed to ascertain the absence of systematic errors cau...

  14. Quality control of systems of portal imaging; Control de calidad de sistemas de imagen portal

    Energy Technology Data Exchange (ETDEWEB)

    Olasolo Alonso, J.; Martin Albina, M. L.; Otal Palacin, A.; Fuentemilla Urio, N.; Miquelez Alonso, S.; Pellejero Pellejero, S.; Maneru Camara, F.; Lozares Cordero, S.; Rubio Arroniz, A.

    2013-07-01

    The importance of accuracy and reproducibility of the positioning of the patient for the radiotherapy treatment, makes key the image quality of the image device portal used for the verification of such positioning. the objective of this work is the implementation of a procedure of quality control that easily and quickly verify the main parameters of image quality of the EPID. (Author)

  15. Model based control charts in stage 1 quality control

    OpenAIRE

    Koning, Alex

    1999-01-01

    textabstractIn this paper a general method of constructing control charts for preliminary analysis of individual observations is presented, which is based on recursive score residuals. A simulation study shows that certain implementations of these charts are highly effective in detecting assignable causes.

  16. Different Methods for Prostate Biopsy and Biopsy Protocols

    Directory of Open Access Journals (Sweden)

    Mahyar Ghafoori

    2011-05-01

    Full Text Available Prostate carcinoma is one of the most common"nmalignancies among men. Increasing mortality rates due"nto prostate carcinoma have been observed worldwide."nThis disease usually progresses imperceptibly, for this"nreason; screening programs aimed at early detection"nhave been developed. The prostate specific antigen"n(PSA test is among the best screening tools available"nin medicine today because it is recognized as the best"nmarker for its early detection."nIn case of abnormal rise in PSA, the patient usually"nrefers for prostate biopsy under the guide of trans"nrectal ultrasonography (TRUS. Different methods are"nrecognized for prostate biopsy that may be divided"ninto two main categories namely, systematic biopsy"nand targeted biopsy."nIn systematic biopsy we divide the prostate gland"nrandomly to different sections and obtain biopsy"nspecimens from each section.The protocol of systematic biopsy is different among"ndifferent institutions. The number of biopsy specimens"ncould be started from less than 6 to more than 20"nbiopsies in some institutions. Increasing the number"nof biopsy specimens increases the detection rate for"nprostate cancer increasing the complications such"nas post biopsy prostatitis and septicemia, which are"nthe most important, as well. In scheduling a biopsy"nprotocol with high number of biopsies it is preferred"nto hospitalize the patient and prescribe intravenous"nantibiotics."nTargeted biopsy of the prostate means obtaining biopsy"nspecimens from a pathologic lesion that is suspicious"nfor prostate cancer. Different modalities could be"nused for detecting prostate cancer within the prostate"ngland. Transrectal ultrasonography, ultrasonography"nwith the use of ultrasound contrast agents, MRI of the"nprostate with the use of endorectal coil, dynamic MR"nstudy with contrast agent, diffusion weighted imaging"nof the prostate and MR spectroscopy all could help"nin the detection of a suspicious tumoral mass in the

  17. Usefulness of automated biopsy guns in image-guided biopsy

    International Nuclear Information System (INIS)

    To evaluate the usefulness of automated biopsy guns in image-guided biopsy of lung, liver, pancreas and other organs. Using automated biopsy devices, 160 biopsies of variable anatomic sites were performed: Biopsies were performed under ultrasonographic(US) guidance in 95 and computed tomographic (CT) guidance in 65. We retrospectively analyzed histologic results and complications. Specimens were adequate for histopathologic diagnosis in 143 of the 160 patients(89.4%)-Diagnostic tissue was obtained in 130 (81.3%), suggestive tissue obtained in 13(8.1%), and non-diagnostic tissue was obtained in 14(8.7%). Inadequate tissue was obtained in only 3(1.9%). There was no statistically significant difference between US-guided and CT-guided percutaneous biopsy. There was no occurrence of significant complication. We have experienced mild complications in only 5 patients-2 hematuria and 2 hematochezia in transrectal prostatic biopsy, and 1 minimal pneumothorax in CT-guided percutaneous lung biopsy. All of them were resolved spontaneously. The image-guided biopsy using the automated biopsy gun was a simple, safe and accurate method of obtaining adequate specimen for the histopathologic diagnosis

  18. Telepathology and Optical Biopsy

    Directory of Open Access Journals (Sweden)

    Olga Ferrer-Roca

    2009-01-01

    Full Text Available The ability to obtain information about the structure of tissue without taking a sample for pathology has opened the way for new diagnostic techniques. The present paper reviews all currently available techniques capable of producing an optical biopsy, with or without morphological images. Most of these techniques are carried out by physicians who are not specialized in pathology and therefore not trained to interpret the results as a pathologist would. In these cases, the use of telepathology or distant consultation techniques is essential.

  19. The impact of quality control in RNA-seq experiments

    Science.gov (United States)

    Merino, Gabriela A.; Fresno, Cristóbal; Netto, Frederico; Dias Netto, Emmanuel; Pratto, Laura; Fernández, Elmer A.

    2016-04-01

    High throughput mRNA sample sequencing, known as RNA-seq, is as a powerful approach to detect differentially expressed genes starting from millions of short sequence reads. Although several workflows have been proposed to analyze RNA-seq data, the experiment quality control as a whole is not usually considered, thus potentially biasing the results and/or causing information lost. Experiment quality control refers to the analysis of the experiment as a whole, prior to any analysis. It not only inspects the presence of technical effects, but also if general biological assumptions are fulfilled. In this sense, multivariate approaches are crucial for this task. Here, a multivariate approach for quality control in RNA-seq experiments is proposed. This approach uses simple and yet effective well-known statistical methodologies. In particular, Principal Component Analysis was successfully applied over real data to detect and remove outlier samples. In addition, traditional multivariate exploration tools were applied in order to asses several controls that can help to ensure the results quality. Based on differential expression and functional enrichment analysis, here is demonstrated that the information retrieval is significantly enhanced through experiment quality control. Results show that the proposed multivariate approach increases the information obtained from RNA-seq data after outlier samples removal.

  20. Secondary Control for Voltage Quality Enhancement in Microgrids

    DEFF Research Database (Denmark)

    Savaghebi, Mehdi; Jalilian, Alireza; Vasquez, Juan Carlos;

    2012-01-01

    In this paper, a hierarchical control scheme is proposed for enhancement of sensitive load bus (SLB) voltage quality in microgrids. The control structure consists of primary and secondary levels. The primary control level comprises distributed generators (DGs) local controllers. Each...... level is applied to manage the compensation of SLB voltage unbalance and harmonics by sending proper control signals to the primary level. DGs compensation efforts are controlled locally at the primary level. The system design procedure for selecting proper control parameters is discussed. Simulation...... of these controllers includes a selective virtual impedance loop which is considered to improve sharing of fundamental and harmonic components of load current among the DG units. The sharing improvement is provided at the expense of increasing voltage unbalance and harmonic distortion. Thus, the secondary control...

  1. 75 FR 80066 - Quality Control Requirements for Direct Endorsement Lenders; Notice of Proposed Information...

    Science.gov (United States)

    2010-12-21

    ... URBAN DEVELOPMENT Quality Control Requirements for Direct Endorsement Lenders; Notice of Proposed.... This Notice also lists the following information: Title of Proposal: Quality Control Requirements for... lenders, since these institutions must also conduct quality control on all loans they originate...

  2. 78 FR 69103 - 30-Day Notice of Proposed Information Collection: Quality Control for Rental Assistance Subsidy...

    Science.gov (United States)

    2013-11-18

    ... URBAN DEVELOPMENT 30-Day Notice of Proposed Information Collection: Quality Control for Rental... Information Collection: Quality Control for Rental Assistance Subsidy Determinations. OMB Approval Number... Quality Control process involves selecting a nationally representative sample of assisted households...

  3. The Emprovement of Percutaneous Puncture Core Renal Biopsy in Diffuse Diseases

    Directory of Open Access Journals (Sweden)

    Vdovin А.К.

    2013-09-01

    Full Text Available We developed methods to improve ultrasound-guided percutaneous renal puncture core biopsy in diffuse diseases. The use of semi-automatic needles True-Cut, caliber 14G, with harpoon-type mandrin, which enables to obtain high-quality tissue samples, up to 2 cm in length and up to 1.2 mm in thickness that makes it possible to perform a single tissue retrieval (2–3 — in exceptional cases. 40 patients underwent “free hand” biopsy using semi-automatic needles. The peculiarity of the suggested technique of biopsy needle visualization improvement is in the creation of induced anechoic space in paranephral cellular tissue by means of tissue infiltration by 0.25% novocaine solution. It helps to localize the tip of a mandrin immediately close to the renal surface and enables its controlled introduction into the selected biopsy area. To avoid the calices-pelvis system or vessel damage, the approach is along the line going obliquely superiorly down through parenchyma of the middle third of the kidney towards the lower pole at sufficient distance from the renal sinus echostructures. Informative material for histological study was obtained without complications in all cases. The optimized biopsy technique permits early activization of patients and their reduced (up to one day stay in hospital.

  4. Quality control of radioactive waste disposal container for borehole project

    International Nuclear Information System (INIS)

    This paper explained quality control of radioactive disposal container for the borehole project. Non-destructive Testing (NDT) is one of the quality tool used for evaluating the product. The disposal container is made of 316L stainless steel. The suitable NDT method for this object is radiography, ultrasonic, penetrant and eddy current testing. This container will be filled with radioactive capsules and cement mortar is grouted to fill the gap. The results of NDT measurements are explained and discussed. (author)

  5. Quality Assurance and Control in Laboratory using Neutron Activation Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Y. S.; Moon, J. H.; Sun, G. M.; Kim, S. H.; Baek, S. Y.; Lim, J. M.; Kim, H. R

    2007-01-15

    In accordance with the increment of international trade associated with the worldwide globalization, the importance of quality assurance and control for the commodity produced from one's own country has been stressed. ISO (International Organization for Standards) defines quality control as 'the operational techniques and activities that are used to fulfill the requirements for quality'. Since 1996, the HANARO research reactor in the Korea Atomic Energy Research Institute has been operated thereafter initial critical operation on April 1995. Neutron activation analysis system and applied techniques which is one of a nuclear analytical technologies using reactor neutrons has been developed for user's supporting and the establishment of the quality system for a measurement and analysis, testing and inspection was implemented successfully. On the basis of the qualified NAA system, the test and measurement of more than 1500 samples which is requested from 30 organizations including industrial companies, universities and institutes carried out in NAA laboratory annually. Moreover, as the goal of mutual recognition agreement (MRA) which can be removed a technical barrier in international trade, the objectivity and the confidence of analytical quality in NAA laboratory became established through the installation of international accreditation system by implementing analytical quality system in accordance with international standards in 2001. The aim of the report was to summarize the technical management of introduction, methods and the results for a quality control and assurance which should be performed in NAA technique using the HANARO research reactor. The report will help building up effective quality control strategy in the future.

  6. Theoretical White Dwarf Spectra via the Internet: Quality Control

    Science.gov (United States)

    Ringat, E.; Reindl, N.

    2013-01-01

    The first decade of the Virtual Observatory (VO) built up services and tools for data conservation, handling, processing, analysis, etc. A new challenge in the immensely growing VO in operation is continuous quality control at different authority levels. Here we shed light on various aspects of theoretical white dwarf spectra that are provided via the registered TheoSSA VO service. We present benchmark tests that enable the VO user to judge their quality.

  7. 40 CFR 81.77 - Puerto Rico Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Puerto Rico Air Quality Control Region... PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.77 Puerto Rico Air Quality Control Region. The Puerto Rico Air Quality Control...

  8. The Quality Control of the LHC Continuous Cryostat Interconnections

    CERN Document Server

    Bertinelli, F; Bozzini, D; Cruikshank, P; Fessia, P; Grimaud, A; Kotarba, A; Maan, W; Olek, S; Poncet, A; Russenschuck, Stephan; Savary, F; Sulek, Z; Tock, J P; Tommasini, D; Vaudaux, L; Williams, L

    2008-01-01

    The interconnections between the Large Hadron Collider (LHC) magnets have required some 40 000 TIG welded joints and 65 000 electrical splices. At the level of single joints and splices, non-destructive techniques find limited application: quality control is based on the qualification of the process and of operators, on the recording of production parameters and on production samples. Visual inspection and process audits were the main techniques used. At the level of an extended chain of joints and splices - from a 53.5 m half-cell to a complete 2.7 km arc sector - quality control is based on vacuum leak tests, electrical tests and RF microwave reflectometry that progressively validated the work performed. Subsequent pressure tests, cryogenic circuits flushing with high pressure helium and cool-downs revealed a few unseen or new defects. This paper presents an overview of the quality control techniques used, seeking lessons applicable to similar large, complex projects.

  9. Quality control for exposure assessment in epidemiological studies

    DEFF Research Database (Denmark)

    Bornkessel, C; Blettner, M; Breckenkamp, J;

    2010-01-01

    In the framework of an epidemiological study, dosemeters were used for the assessment of radio frequency electromagnetic field exposure. To check the correct dosemeter's performance in terms of consistency of recorded field values over the entire study period, a quality control strategy...... was developed. In this paper, the concept of quality control and its results is described. From the 20 dosemeters used, 19 were very stable and reproducible, with deviations of a maximum of +/-1 dB compared with their initial state. One device was found to be faulty and its measurement data had to be excluded...... from the analysis. As a result of continuous quality control procedures, the confidence in the measurements obtained during the field work was strengthened significantly....

  10. Development and use of reference materials and quality control materials

    International Nuclear Information System (INIS)

    Current knowledge is summarized on correct use of commercially available certified reference materials (CRMs) and reference materials (RMs). Acknowledged are also the limitations and restrictions analysts have to face if they want to apply quality control. The concept of in-house RMs or quality control materials (QCMs) is advocated to supplement the use of CRMs for quality control purposes. On hand advice on how to select, prepare, characterize and use these QCMs is given from the experts' perspective. Several scenarios are described to make this concept widely applicable to: advanced laboratories with CRMs with validated analytical techniques available, laboratories with less experience and facilities, as well as cases were labile compounds and unstable matrices are involved. Each scenario considers different approaches to overcome the lack of appropriate CRMs and advise on the preparation of QCMs, which might fit the particular purpose

  11. Methods of Statistical Control for Groundwater Quality Indicators

    Science.gov (United States)

    Yankovich, E.; Nevidimova, O.; Yankovich, K.

    2016-06-01

    The article describes the results of conducted groundwater quality control. Controlled quality indicators included the following microelements - barium, manganese, iron, mercury, iodine, chromium, strontium, etc. Quality control charts - X-bar chart and R chart - were built. For the upper and the lower threshold limits, maximum permissible concentration of components in water and the lower limit of their biologically significant concentration, respectively, were selected. The charts analysis has shown that the levels of microelements content in water at the area of study are stable. Most elements in the underground water are contained in concentrations, significant for human organisms consuming the water. For example, such elements as Ba, Mn, Fe have concentrations that exceed maximum permissible levels for drinking water.

  12. Quality assurance/quality control, reliability and availability of nuclear power plants

    International Nuclear Information System (INIS)

    In a first part this lectures will present a survey on nuclear power production and plant performance in the Western World and discuss key parameters such as load factors and non-availability. Some main reasons for reliable performance of nuclear power plants are given. The second part of this lecture deals with the question how quality assurance and quality control measures do directly influence plant reliability, availability and, thus, economy. Derived from worldwide experience gained from operating nuclear power plants, it may be concluded that the implementation of an overall quality assurance programme does not only satisfy safety requirements set forth by the nuclear regulatory bodies, but has also a considerable impact on plant reliability and availability. A positive effect on these figures will be achieved if the established quality assurance programme provides for a coordinated approach to all activities affecting quality. It is discussed how the quality of a product should be controlled and what kind of quality assurance measures by performed examples are given to demonstrate that the expenditure for maintenance work on components will decrease if planned and systematic quality assurance actions have been implemented during all procurement stages. (orig./RW)

  13. Ultrasound-guided synovial biopsy: a safe, well-tolerated and reliable technique for obtaining high-quality synovial tissue from both large and small joints in early arthritis patients.

    OpenAIRE

    Kelly, S; Humby, F; Filer, A; Ng, N.; Di Cicco, M; Hands, RE; Rocher, V; Bombardieri, M; D'Agostino, MA; McInnes, IB; Buckley, CD; Taylor, PC; Pitzalis, C

    2013-01-01

    OBJECTIVE: To determine the tolerability, safety and yield of synovial tissue in an early arthritis cohort using a minimally invasive, ultrasound (US)-guided, synovial biopsy technique in small, medium and large joints. METHODS: 93 sequential biopsy procedures were assessed from a total of 57 patients (baseline and 36 repeat biopsies at 6 months) recruited as part of the 'Pathobiology of Early Arthritis Cohort' study. Patients completed a tolerability questionnaire prior to and following the ...

  14. Axillary recurrence after sentinel lymph node biopsy

    NARCIS (Netherlands)

    van der Vegt, B; Doting, MHE; Jager, PL; Wesseling, J; de Vries, J

    2004-01-01

    Sentinel lymph node biopsy (SLNB) without further axillary dissection in patients with sentinel node-negative breast carcinoma appears to be a safe procedure to ensure locoregional control. During a median follow-up of 35 months the false-negative rate was 1% in our study population of 185 patients.

  15. Study of prostate biopsy robot system

    Institute of Scientific and Technical Information of China (English)

    ZHANG Yong-de; ZHANG Long; ZHAO Yan-jiang; ZHANG Yan-hua

    2009-01-01

    A system for prostate biopsy with robot assistance was proposed. The system consists of Motoman robot, needle insertion mechanism, and control software. A experiment was held with this software, and it proved that the whole system is simple, reliable and good application.

  16. Results of a quality control on non-interventional studies

    Directory of Open Access Journals (Sweden)

    Hundt, Ferdinand

    2011-01-01

    Full Text Available Non-interventional studies (NIS have for decades been an established part of post-authorisation medicinal research. As early as the mid-nineties, there were at least rudimentary demands for controllable data quality. Beginning with the recommendations of the Federal Institute for Drugs and Medical Devices (BfArM on the execution of non interventional (observational studies of 1998 and finally with the guidelines and recommendations for ensuring Good Epidemiological Practice (GEP, with the VFA (Verband der forschenden Arzneimittelhersteller [German Association of Research-Based Pharmaceutical Companies] – Recommendations for the Improvement of Quality and Transparency of NIS and the joint recommendations of BfArM and PEI (Paul-Ehrlich-Institut on the execution of NIS, pharmaceutical companies are required to monitor and/or verify quality in the course of a project. According to a survey of pharmaceutical companies 2010, about one third of the companies surveyed to date carry out such quality controls on site, at participating study centres.This report deals with the results of such quality control measures in 4 completed projects. The control rates defined in the respective cohort study plans, the measures carried out on site and any consequent measures, such as adjustment of forms, reduction of consultation time and necessary organisational changes are described. A high level of agreement between the data collected and the original patient documents is found, comparable to that in clinical trials.

  17. Results of a quality control on non-interventional studies.

    Science.gov (United States)

    Wörz, Karl; Hundt, Ferdinand

    2011-01-01

    Non-interventional studies (NIS) have for decades been an established part of post-authorisation medicinal research. As early as the mid-nineties, there were at least rudimentary demands for controllable data quality. Beginning with the recommendations of the Federal Institute for Drugs and Medical Devices (BfArM) on the execution of non interventional (observational) studies of 1998 and finally with the guidelines and recommendations for ensuring Good Epidemiological Practice (GEP), with the VFA (Verband der forschenden Arzneimittelhersteller [German Association of Research-Based Pharmaceutical Companies]) - Recommendations for the Improvement of Quality and Transparency of NIS and the joint recommendations of BfArM and PEI (Paul-Ehrlich-Institut) on the execution of NIS, pharmaceutical companies are required to monitor and/or verify quality in the course of a project. According to a survey of pharmaceutical companies 2010, about one third of the companies surveyed to date carry out such quality controls on site, at participating study centres. This report deals with the results of such quality control measures in 4 completed projects. The control rates defined in the respective cohort study plans, the measures carried out on site and any consequent measures, such as adjustment of forms, reduction of consultation time and necessary organisational changes are described. A high level of agreement between the data collected and the original patient documents is found, comparable to that in clinical trials. PMID:21863135

  18. Control of weld quality in large welded populations

    International Nuclear Information System (INIS)

    The use of factorial experimental design during weld procedure development, as a statistical tool for the control of weld quality in large welded populations, is investigated. As an example, it is applied to single pass welds made in the laboratory using the spacer to tube attachment geometry present in AGR boilers. The welds have been deposited using a robotic cold wire TIG technique. A replicated 25 factorial welding trial has been designed and evaluated experimentally. Transverse sections have been examined to determine weld penetration quality features. The means and variances of each quality feature have been calculated. Using a standard factorial analysis program the significant effects have been identified and incorporated into control equations. Using these data and having established minimum acceptance criteria. defect rates have been calculated as a function of weld position. The control equations have also been used to revise working point welding conditions, to achieve acceptable weld quality. These equations have also been used in conjunction with the reproducibility measurements to estimate the amount of weld quality variability that can be attributed to process control. (author)

  19. Review of 18F-FDG Synthesis and Quality Control

    OpenAIRE

    Yu, S.

    2006-01-01

    This review article covers a concise account on fludeoxyglucose (18F–FDG) synthesis and quality control procedures with emphasis on practical synthesis Currently, 18F–FDG is the most successful PET radiopharmaceutical so far. The advancement in synthesis and quality control of 18F–FDG, together with its approval by the US FDA and the availability of reimbursement, are probably the main reasons for the flourish of clinical PET over the last 20 years. 18F–FDG can be synthesised by either electr...

  20. Mitochondrial Quality Control: Decommissioning Power Plants in Neurodegenerative Diseases

    Directory of Open Access Journals (Sweden)

    Rukmini Mukherjee

    2013-01-01

    Full Text Available The cell has an intricate quality control system to protect its mitochondria from oxidative stress. This surveillance system is multi-tiered and comprises molecules that are present inside the mitochondria, in the cytosol, and in other organelles like the nucleus and endoplasmic reticulum. These molecules cross talk with each other and protect the mitochondria from oxidative stress. Oxidative stress is a fundamental part of early disease pathogenesis of neurodegenerative diseases. These disorders also damage the cellular quality control machinery that protects the cell against oxidative stress. This exacerbates the oxidative damage and causes extensive neuronal cell death that is characteristic of neurodegeneration.

  1. Quality Control of a detector probe for radio guided surgery; Control de calidad de una sonda detectora para cirugia radioguiada

    Energy Technology Data Exchange (ETDEWEB)

    Barreto, A. C.; Cardoso, G.; Ferreira, L. S.; Santos, A.

    2013-07-01

    Breast cancer is the most common tumor in women, with increasing incidence worldwide. The dissection axillary lymph node is a reason for increased morbidity of breast surgery and have been replaced by sentinel node biopsy. The quality and performance of the detector probe affect the success of sentinel node surgery. The main objective of this work is to develop a set of practical tests to evaluate the performance of a probe for detecting sentinel node. (Author)

  2. [Study thought of pharmaceutical preparations quality standards by dynamic quality control technology].

    Science.gov (United States)

    Yu, Dan-Hong; Mao, Chen-Mei; Lv, Cheng-Zhe; Jin, Hui-Zhen; Yao, Xin; Jia, Xiao-Bin

    2014-07-01

    Pharmaceutical preparations, particularly as a "secret recipe" of traditional Chinese medicine in medical institutions, are the product of China's medical and health industry, and they are also an important means of competing of different medical institutions. Although pharmaceutical preparations have advantages and characteristics than institutes for drug and pharmaceutical companies, the quality standards of pharmaceutical preparations in medical institutions has not reached the desired level over the years. As we all know, the quality of pharmaceutical preparations is important to ensure the efficacy, especially under the environment of people pay more sttention on drug safety and effectiveness and contry increase emphasis on the stste of pharmaceutical preparations. In view of this, we will improve the grade, stability, and clinical efficacy of pharmaceutical preparations by the advanced equipment, testing instruments and the process dynamic quality control technology. Finally, we hope we can provide new ideas for the quality control of pharmaceutical preparations. PMID:25272516

  3. The accuracy of colposcopic biopsy

    DEFF Research Database (Denmark)

    Stoler, Mark H; Vichnin, Michelle D; Ferenczy, Alex;

    2011-01-01

    We evaluated the overall agreement between colposcopically directed biopsies and the definitive excisional specimens within the context of three clinical trials. A total of 737 women aged 16-45 who had a cervical biopsy taken within 6 months before their definitive therapy were included. Per......-protocol, colposcopists were to also obtain a representative cervical biopsy immediately before definitive therapy. Using adjudicated histological diagnoses, the initial biopsies and the same day biopsies were correlated with the surgically excised specimens. The overall agreement between the biopsies taken within 6...... months of definitive therapy, and the definitive therapy diagnoses was 42% (weighted kappa = 0.34) (95% CI: 0.29-0.39). The overall underestimation of cervical intraepithelial neoplasia grade 2/3 or adenocarcinoma in situ (CIN2-3/AIS) and CIN3/AIS was 26 and 42%, respectively. When allowing for one...

  4. 21 CFR 111.127 - What quality control operations are required for packaging and labeling operations?

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 2 2010-04-01 2010-04-01 false What quality control operations are required for... and Process Control System: Requirements for Quality Control § 111.127 What quality control operations are required for packaging and labeling operations? Quality control operations for packaging...

  5. 21 CFR 111.130 - What quality control operations are required for returned dietary supplements?

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 2 2010-04-01 2010-04-01 false What quality control operations are required for... and Process Control System: Requirements for Quality Control § 111.130 What quality control operations are required for returned dietary supplements? Quality control operations for returned...

  6. Quality

    International Nuclear Information System (INIS)

    What is quality? How do you achieve it? How do you keep it once you have got it. The answer for industry at large is the three-step hierarchy of quality control, quality assurance and Total quality Management. An overview is given of the history of quality movement, illustrated with examples from Schlumberger operations, as well as the oil industry's approach to quality. An introduction of the Schlumberger's quality-associated ClientLink program is presented. 15 figs., 4 ills., 16 refs

  7. Chinese vaccine products go global: vaccine development and quality control.

    Science.gov (United States)

    Xu, Miao; Liang, Zhenglun; Xu, Yinghua; Wang, Junzhi

    2015-05-01

    Through the continuous efforts of several generations, China has become one of the few countries in the world that is capable of independently addressing all the requirements by the Expanded Program on Immunization. Regulatory science is applied to continuously improve the vaccine regulatory system. Passing the prequalification by WHO has allowed Chinese vaccine products to go global. Chinese vaccine products not only secure disease prevention and control domestically but also serve the needs for international public health. This article describes the history of Chinese vaccine development, the current situation of Chinese vaccine industry and its contribution to the prevention and control of infectious diseases. We also share our experience of national quality control and vaccine regulation during the past decades. China's experience in vaccine development and quality control can benefit other countries and regions worldwide, including the developing countries.

  8. Process and quality verification controls for solid propellant manufacturing

    Science.gov (United States)

    Rogers, C. J.

    1983-01-01

    It is pointed out that in-process tests to verify quality and detect discrepant propellant which could compromise motor performance are essential elements of the solid composite propellant manufacturing process. The successful performance of the 260SL-1 and 260SL-2 motors aptly verified the controls used for manufacturing the propellant. The present investigation is concerned with the selected control parameters, and their relationships to composition and final propellant properties. Control performance is evaluated by comparison with processing data experienced in the manufacture of the propellant for the 260SL-1 motor. It is found that the in-process quality verification controls utilized in the propellant manufacturing process for the 260-in. diameter motor contributed significantly to the confidence of successful and predictable motor performance.

  9. Quality control for the continuous casting process using electromagnetic transducers

    OpenAIRE

    I.S. Kim; Son, J.S.; Kim, H. J.; B.S. Sung

    2008-01-01

    Purpose: The continuous casting process is controlled automatically because various sensors and control unitsare connected to the mold and lower tundish roll. The solidification point in the process has a major factor onthe quality of products, but the point has been predicted depending on the inaccurate calculated results from acomputer simulation until now. Therefore, the objective of this paper is to develop the EMAT sensors for themeasurement of the solidification point made by a through ...

  10. Analytical quality control in studies of environmental exposure to mercury

    International Nuclear Information System (INIS)

    The work of the laboratory for quality control in this co-ordinated project for the period from November 1993 to June 1994 is presented. The major effort was devoted to assisting in establishing the homogeneity and total methylmercury levels in two new hair reference materials prepared as control materials for the project, numbered 085 (spiked) and 086 (natural level). Results for some hair materials from participants are also given. (author)

  11. Universal Power Quality Controller Modeling and Inverters Loading Analysis

    Directory of Open Access Journals (Sweden)

    F. Gharedaghi

    2011-11-01

    Full Text Available As much as nonlinear loads and power electronics devices are more applied in power distribution systems, the importance of power quality increases. This study proposes a Universal Power Quality Conditioner (UPQC with double-converter structure. The operation principle, the algorithm of compensation reference generation, and the control method are introduced. Computer simulation and many prototype experiments are carried out to verify the operation principle and investigate the compensation characteristics of UPQC for different power quality problems. It is verified that the UPQC can effectively compensate multiple different power quality interferences originated either from the load side or from the line side. The capacity of series and shunt inverters is calculated through loading calculations of these inverters applying phasor diagram to increase the design accuracy. The results of simulation in MATLAB/SIMULINK software show that the system operates correctly.

  12. Implementation of quality control program in radiodiagnostic services

    International Nuclear Information System (INIS)

    This monograph is the first version of the implementation of the quality control programme in radiology diagnostic services. Here all information related to diagnostic quality to better radiation protection to patients and personnel was collected. The programme was implemented on the X-ray equipment at three hospitals (named hospital A, hospital B and hospital C) and included the evaluation of technical parameters such as kilovolts, exposition time, filtration, fields. In addition, dark room, chassis and image intensifiers were also evaluated. The procedures to carry out the quality control and the manner in which the observations, conclusions and recommendations should be formulated are based on documents issued by the International Commission on Radiological Protection (I.C.R.P.), International Atomic Energy Agency (I.A.E.A.) and World Health Organization (W.H.O.)

  13. Statistical Data Mining for Efficient Quality Control in Manufacturing

    DEFF Research Database (Denmark)

    Khan, Abdul Rauf; Schiøler, Henrik; Knudsen, Torben Steen;

    2015-01-01

    of the process e.g sensor measurements, machine readings etc, and the major contributor of these big data sets are different quality control processes. In this article we will present methodology to extract valuable insight from manufacturing data. The proposed methodology is based on comparison of probabilities...

  14. Quality Control Charts in Large-Scale Assessment Programs

    Science.gov (United States)

    Schafer, William D.; Coverdale, Bradley J.; Luxenberg, Harlan; Jin, Ying

    2011-01-01

    There are relatively few examples of quantitative approaches to quality control in educational assessment and accountability contexts. Among the several techniques that are used in other fields, Shewart charts have been found in a few instances to be applicable in educational settings. This paper describes Shewart charts and gives examples of how…

  15. Quality Control in Primary Schools: Progress from 2001-2006

    Science.gov (United States)

    Hofman, Roelande H.; de Boom, Jan; Hofman, W. H. Adriaan

    2010-01-01

    This article presents findings of research into the quality control (QC) of schools from 2001-2006. In 2001 several targets for QC were set and the progress of 939 primary schools is presented. Furthermore, using cluster analysis, schools are classified into four QC-types that differ in their focus on school (self) evaluation and school…

  16. Transcription-associated quality control of mRNP

    DEFF Research Database (Denmark)

    Schmid, Manfred; Jensen, Torben Heick

    2013-01-01

    Although a prime purpose of transcription is to produce RNA, a substantial amount of transcript is nevertheless turned over very early in its lifetime. During transcription RNAs are matured by nucleases from longer precursors and activities are also employed to exert quality control over the RNA ...

  17. Monitoring Leptospira Strain Collections: The Need for Quality Control

    NARCIS (Netherlands)

    G.M. Cerqueira; A.J.A. McBride; A. Queiroz; L.S. Pinto; E.E. Silva; R.A. Hartskeerl; M.G. Reis; A.I. Ko; O.A. Dellagostin

    2010-01-01

    The purpose of this study was to perform a 16S sequence-based quality control of two Leptospira strain collections. 16S rRNA gene sequencing was used to verify two Leptospira reference collections provided by the World Health Organization and maintained at a reference laboratory for leptospirosis in

  18. Quality control procedure for dental x-ray film processing

    International Nuclear Information System (INIS)

    Methods of obtaining the optimum processing from dental films are discussed. A method of quality control of developing conditions for dental x-ray films has been developed. It is relatively easy to maintain and is sufficiently accurate for practical purposes

  19. Quality Control through Design and Process: Gambrel Roof Truss Challenge

    Science.gov (United States)

    Ward, Dell; Jones, James

    2011-01-01

    Customers determine whether a product fulfills their needs or satisfies them. "Quality control", then, is the process of finding out what the customer wants, along with designing, producing, delivering, and servicing the product--and ultimately satisfying the customer's expectations. For many years, people considered a product to be of good…

  20. Quality control tests for the CMS Barrel RPCs

    International Nuclear Information System (INIS)

    An RPC based system will be employed for the CMS muon first level trigger. Severe quality controls and certification have been established all along the entire production chain. Procedures are briefly described and results for the acceptance percentage are given for the second part of the single gaps and double gaps production. Summary results are also reported for the full sets of tested chambers

  1. Preserving organelle vitality : peroxisomal quality control mechanisms in yeast

    NARCIS (Netherlands)

    Aksam, Eda Bener; de Vries, Bart; van der Klei, Ida J.; Kiel, Jan A. K. W.

    2009-01-01

    Cellular proteins and organelles such as peroxisomes are under continuous quality control. Upon synthesis in the cytosol, peroxisomal proteins are kept in an import-competent state by chaperones or specific proteins with an analogous function to prevent degradation by the ubiquitin-proteasome system

  2. Quality control of leather by terahertz time-domain spectroscopy.

    Science.gov (United States)

    Hernandez-Serrano, A I; Corzo-Garcia, S C; Garcia-Sanchez, E; Alfaro, M; Castro-Camus, E

    2014-11-20

    We use terahertz time-domain spectroscopy, combined with effective-medium theory, to measure the moisture content and thickness of leather simultaneously. These results demonstrate that this method could become a standard quality control test for the industrial tanning process. PMID:25607861

  3. Quality control and quality assurance philosophy introduced in national personnel dosimetry service

    International Nuclear Information System (INIS)

    There in National Personnel Dosimetry Service (NPDS) the implementation of the control system to guarantee the credibility of the measured personal dose equivalents results was given on the basis of the international recommendations published by the European Commission and the IAEA and in particular of the decree of the SUJB No. 132/2008 Coll. The quality control and the quality assurance are carried out in all three personal dosimetry services introduced in NPDS: in the film badge, thermoluminescent (TL) and neutron dosimetry. (authors)

  4. Incorporating Quality Control Information in the Sensor Web

    Science.gov (United States)

    Devaraju, Anusuriya; Kunkel, Ralf; Bogena, Heye

    2013-04-01

    The rapid development of sensing technologies had led to the creation of large amounts of heterogeneous environmental observations. The Sensor Web provides a wider access to sensors and observations via common protocols and specifications. Observations typically go through several levels of quality control, and aggregation before they are made available to end-users. Raw data are usually inspected, and related quality flags are assigned. Data are gap-filled, and errors are removed. New data series may also be derived from one or more corrected data sets. Until now, it is unclear how these kinds of information can be captured in the Sensor Web Enablement (SWE) framework. Apart from the quality measures (e.g., accuracy, precision, tolerance, or confidence), the levels of observational series, the changes applied, and the methods involved must be specified. It is important that this kind of quality control information is well described and communicated to end-users to allow for a better usage and interpretation of data products. In this paper, we describe how quality control information can be incorporated into the SWE framework. Concerning this, first, we introduce the TERENO (TERrestrial ENvironmental Observatories), an initiative funded by the large research infrastructure program of the Helmholtz Association in Germany. The main goal of the initiative is to facilitate the study of long-term effects of climate and land use changes. The TERENO Online Data RepOsitORry (TEODOOR) is a software infrastructure that supports acquisition, provision, and management of observations within TERENO via SWE specifications and several other OGC web services. Next, we specify changes made to the existing observational data model to incorporate quality control information. Here, we describe the underlying TERENO data policy in terms of provision and maintenance issues. We present data levels, and their implementation within TEODOOR. The data levels are adapted from those used by

  5. Serial correlation of quality control data--on the use of proper control charts

    DEFF Research Database (Denmark)

    Winkel, P; Zhang, Nevin

    2004-01-01

    Biochemical quality control (QC) data have been reported to be autocorrelated. Serial correlation may increase the rate of false alarms if the traditional exponentially weighted moving average (EWMA) control chart to monitoring the process mean is used. False alarms are the focus of this paper......, where an alarm is defined as the occurrence of a QC value outside the three standard deviation control limits....

  6. Investigating Friendship Quality: An Exploration of Self-Control and Social Control Theories' Friendship Hypotheses

    Science.gov (United States)

    Boman, John H., IV; Krohn, Marvin D.; Gibson, Chris L.; Stogner, John M.

    2012-01-01

    While associations with deviant peers are well understood to impact individual development, less is understood about the relationship between friendship quality and delinquency. Two criminological theories--social control theory and self-control theory--are able to offer an explanation for the latter relationship. Social control and self-control…

  7. Quality control of radioimmunoassay kits of pituitary hormones

    International Nuclear Information System (INIS)

    The present work describe the quality control procedures carried out on three RIA-Kits by the Isotopes Centre of Cuba, The subject matter of study were ;: were: LH-RIA-Kit, FSH-RIA-Kit and Prolactin- RIA -Kit. The controls have included the characterization of the 125I labelled hormones the specific antibodies, the 2 nd antibodies, the standards curves and the control serum. For the validation of these Kits were used reference standards from the WHO (World Health Organizations) and Kits from CIS company (France) based on the IRMA assays technologies . The results obtained allow us encourage the reliability of RIA-Kits

  8. Physical aspects of quality assurance in radiotherapy: A protocol for quality control

    International Nuclear Information System (INIS)

    In consistency with the increasing requests from Member States for establishing radiotherapy programmes, an IAEA Technical Co-operation project was initiated in Latin America aimed at improving the physical aspects (as a complement to the clinical issues) of quality assurance in radiotherapy; this ARCAL XXX project (RLA/6/032) was classified as a Model Project of the IAEA. Among the important outcomes of the project were (i) the training of a considerable number of medical physicists in hospitals of the region, (ii) the development of a protocol for quality control procedures, and (iii) the organization of quality audit site visits (to the participant countries) where the implementation in hospitals of the developed quality control procedures is verified. The present publication is the protocol for quality control of the physical aspects of radiotherapy. It contains detailed procedures on what should be measured by a medical physicist in a radiotherapy treatment unit and related equipment, and how this should be made. The latter is made through several appendices, which make the document rather unique. The protocol was developed by medical physicists of the region for the professionals of the region, and it is the first document of this kind ever written in Spanish. A training course was organized in November 1998 (Havana, Cuba) where its practical implementation was taught. There are plans to have this document translated into different languages for the various regions having similar TC projects. (author)

  9. 78 FR 55281 - 60-Day Notice of Proposed Information Collection: Quality Control for Rental Assistance Subsidy...

    Science.gov (United States)

    2013-09-10

    ... URBAN DEVELOPMENT 60-Day Notice of Proposed Information Collection: Quality Control for Rental... Collection Title of Proposal: Quality Control for Rental Assistance Subsidy Determinations. OMB Approval... million households covered by the Public Housing and Section 8 housing subsidies. The Quality...

  10. Quality assurance, fabrication, and accompanying quality control of CASTOR {sup registered} transport and storage casks

    Energy Technology Data Exchange (ETDEWEB)

    Beverungen, M.; Laug, R. [GNS Gesellschaft fuer Nuklear-Service mbH, Essen (Germany)

    2004-07-01

    In Germany, the Federal Institute for Materials Research and Testing (BAM, Berlin) acts as the competent authority for the approval of quality assurance measures of packages used in the transport of radioactive material. For this purpose, the German Federal Ministry of Transport issued the ''Technical Guideline on Measures for Quality Assurance (QM) and Quality Surveillance (QUe) for packages for transport of radioactive materials (TRV 006)''. Due to this guideline, every applicant for a cask license is requested to issue a written programme for design, fabrication, testing, documentation, operation, maintenance, and recurrent testing of packages. This programme has to be approved by BAM. Therefore, the company implemented and maintains a programme on basis of the TRV 006 and a Quality Management System on basis of the ISO 9001:2000 which cover all requirements of the guideline to ensure a controlled processes. The system is regularly assessed by BAM.

  11. [MRI-guided musculoskeletal biopsy].

    Science.gov (United States)

    Daecke, W; Libicher, M; Mädler, U; Rumpf, C; Bernd, L

    2003-02-01

    MRI-guided musculoskeletal biopsy has been mentioned to be a minimally invasive method to obtain specimens for diagnostic purposes in bone tumors. To evaluate the viability, to assess the accuracy, and to record possible complications of this method, clinical data of 19 MRI-guided biopsies were analyzed. Interventions were performed on 18 patients (1-78 years) as an outpatient procedure: 15 skeletal and 4 soft tissue biopsies were taken from the pelvis, upper limb,or lower limb. We used T1-weighted gradient echoes (GE) for locating the puncture site and T2-weighted turbo spin echoes (TSE) for visualization of needle position. In 14 of 18 MRI-guided biopsies, a definite histological diagnosis was obtained. According to the pathologist, the inadequate size of the specimen was the main reason for missing the diagnoses in four cases.Long intervention time and inappropriate biopsy tools proved to be the main disadvantages of MRI-guided biopsy, but technical improvement might solve these technical problems in future.A postbiopsy hematoma was the only complication observed. Once technically improved, MRI-guided biopsy could be a precise alternative routine method for musculoskeletal biopsies in future. PMID:12607083

  12. Biopsy of the Transplanted Kidney

    OpenAIRE

    Ahmad, Iftikhar

    2004-01-01

    This article describes the current state-of-the-art technique of percutaneous transplant renal biopsy. A brief overview of the history of transplant renal biopsy is given. The indications and contraindications are discussed, including pre- and postprocedure patient management. The technique of the procedure and the devices that are available in the market are described.

  13. Aspiration and Biopsy: Bone Marrow

    Science.gov (United States)

    ... The person performing the bone marrow aspiration and biopsy will know your medical history, but might ask additional questions, such as what medicines you're taking or whether you have any allergies. Be sure to ... on the aspiration and biopsy site about 30 minutes before the procedure. You ...

  14. Current status of quality evaluation of nursing care through director review and reflection from the Nursing Quality Control Centers

    OpenAIRE

    Duan, Xia; Shi, Yan

    2014-01-01

    Background: The quality evaluation of nursing care is a key link in medical quality management. It is important and worth studying for the nursing supervisors to know the disadvantages during the process of quality evaluation of nursing care and then to improve the whole nursing quality. This study was to provide director insight on the current status of quality evaluation of nursing care from Nursing Quality Control Centers (NQCCs). Material and Methods: This qualitative study used a sample ...

  15. 21 CFR 111.135 - What quality control operations are required for product complaints?

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 2 2010-04-01 2010-04-01 false What quality control operations are required for... System: Requirements for Quality Control § 111.135 What quality control operations are required for product complaints? Quality control operations for product complaints must include reviewing and...

  16. Overall quality control in radiosurgery; Control de calidad global en radiocirugia

    Energy Technology Data Exchange (ETDEWEB)

    Banos Capilla, M. C.; Garcia Martinez, M. a.; Bea Gilbert, J.; Ros Garcia, L.; Gil Deltoro, P.

    2011-07-01

    Quality Control dosimetric and geometric is essential to ensure good treatment in stereotactic radiosurgery. Furthermore, the development of new diagnostic tools CT, MRI, fusion of both) and treatment (micromultilaminas, etc.) Allows increased accuracy thereof, and at the same time. requires a thorough quality control. Currently, the most complete and thorough is the use of dummies which are made multimodal image scans, where different plan dosimetry and radiate in the treatment unit with the relevant detector array.

  17. Renal biopsy: methods and interpretation.

    Science.gov (United States)

    Vaden, Shelly L

    2004-07-01

    Renal biopsy most often is indicated in the management of dogs and cats with glomerular disease or acute renal failure. Renal biopsy can readily be performed in dogs and cats via either percutaneous or surgical methods. Care should be taken to ensure that proper technique is used. When proper technique is employed and patient factors are properly addressed, renal biopsy is a relatively safe procedure that minimally affects renal function. Patients should be monitored during the post biopsy period for severe hemorrhage, the most common complication. Accurate diagnosis of glomerular disease, and therefore, accurate treatment planning,requires that the biopsy specimens not only be evaluated by light microscopy using special stains but by electron and immunofluorescent microscopy. PMID:15223207

  18. Genetic quality control in mass-reared melon flies

    International Nuclear Information System (INIS)

    Quality control in mass-reared melon flies, Bactrocera cucurbitae, after eradication is discussed, based on the results of artificial selection experiments. First, a brief history of quality control in mass-rearing of insects is described. In practical mass- rearing of melon fly, many traits have already been differentiated between mass-reared and wild flies. These differing traits are reviewed and the factors which caused these differences are considered. It was considered that the differences between wild and mass-reared melon flies depended on the selection pressures from the mass-rearing method. Next, the results of several artificial selection experiments using the melon fly are reviewed. Finally, consideration is given to some correlated responses to artificial selection in mass-rearing. Longevity that is correlated to early fecundity was successfully controlled by artificial selection for reproduction in the mass-rearing system. On the basis of these results, an improved method for quality control in mass-reared melon fly with considerations for quantitative genetics is discussed

  19. A Study on Power Quality Improvement in PWM Controlled AC Voltage Controller

    Directory of Open Access Journals (Sweden)

    Ahmet ALTINTAŞ

    2009-04-01

    Full Text Available A lot of topologies of pulse-width modulated (PWM-AC controllers for single-phase and three-phase systems are proposed up to date. PWM-AC controllers have important advantages compared with the phase-controlled AC controllers using thyristors and triacs. The PWM-AC controller has sinusoidal current waveforms, smaller THD values, better power factor, faster dynamics, and smaller input/output filter. This article presents a novel control technique for application to PWM-AC controllers with ability of generating fewer harmonics. In the proposed control method, both the traditional AC voltage controllers and the PWM-AC controllers are combined; and smaller THD values are obtained. Thus, the harmonic pollution in the power system will be reduced; and consequently, the power quality will be increased. For this purpose, computer simulations are performed in order to investigate the proposed controller performance. The obtained results are compared with the conventional PWM-AC controller.

  20. Minimalisasi Kekurangan Material Melalui Implementasi Quality Control Circle

    Directory of Open Access Journals (Sweden)

    Togar W. S. Panjaitan

    2011-01-01

    Full Text Available The revolution of traditional quality management concept into total quality management (TQM inspired industry for establishing and implementing quality control circle (QCC. Before starting a project as the implementation of the QCC, the training was held for supporting the knowledge of the QCC team. As the pilot project of the QCC, this research will try to minimize the percentage of the lack material in the production process of 8340 type by working together with the QCC team. The result of QCC implementation could reach the target set by the team, the percentage of the lack material reached less than 3%. The percentage of the lack material kontaktarm reduced from 3.09% to 0.00%, flachdrahtspule reduced from 9.20% to 0.40%, and niet reduced from 7.71% to 2.73%. Besides, the implementation of QCC also resulted in positive impact for all the members of the team about the benefits and experiences gained.

  1. The consistency approach for the quality control of vaccines.

    Science.gov (United States)

    Hendriksen, Coenraad; Arciniega, Juan L; Bruckner, Lukas; Chevalier, Michel; Coppens, Emmanuelle; Descamps, Johan; Duchêne, Michel; Dusek, David Michael; Halder, Marlies; Kreeftenberg, Hans; Maes, Alexandrine; Redhead, Keith; Ravetkar, Satish D; Spieser, Jean-Marc; Swam, Hanny

    2008-01-01

    Current lot release testing of conventional vaccines emphasizes quality control of the final product and is characterized by its extensive use of laboratory animals. This report, which is based on the outcome of an ECVAM (European Centre for Validation of Alternative Methods, Institute for Health and Consumer Protection, European Commission Joint Research Centre, Ispra, Italy) workshop, discusses the concept of consistency testing as an alternative approach for lot release testing. The consistency approach for the routine release of vaccines is based upon the principle that the quality of vaccines is a consequence of a quality system and of consistent production of lots with similar characteristics to those lots that have been shown to be safe and effective in humans or the target species. The report indicates why and under which circumstances this approach can be applied, the role of the different stakeholders, and the need for international harmonization. It also gives recommendations for its implementation.

  2. Image quality evaluation and control of computer-generated holograms

    Science.gov (United States)

    Yoshikawa, Hiroshi; Yamaguchi, Takeshi; Uetake, Hiroki

    2016-03-01

    Image quality of the computer-generated holograms are usually evaluated subjectively. For example, the re- constructed image from the hologram is compared with other holograms, or evaluated by the double-stimulus impairment scale method to compare with the original image. This paper proposes an objective image quality evaluation of a computer-generated hologram by evaluating both diffraction efficiency and peak signal-to-noise ratio. Theory and numerical experimental results are shown on Fourier transform transmission hologram of both amplitude and phase modulation. Results without the optimized random phase show that the amplitude transmission hologram gives better peak signal-to noise ratio, but the phase transmission hologram provides about 10 times higher diffraction efficiency to the amplitude type. As an optimized phase hologram, Kinoform is evaluated. In addition, we investigate to control image quality by non-linear operation.

  3. Radiological protection and quality control for diagnostic radiology in China

    International Nuclear Information System (INIS)

    Full text: There are 43,000 diagnostic departments, nearly 70,000 X-ray diagnostic facilities, 7,000 CT, 250 million for the annual total numbers of X-ray examinations, 120,000 occupationally exposed workers in diagnostic radiology. 'Basic standards for protection against ionizing radiation and for the safety of radiation sources' is promulgated on October, 2002. This basic standard follows the BSS. 'Rule on the administration of radio-diagnosis and radiotherapy', as a order of the Ministry of Health No. 46, is promulgated by Minister of Health on January 24, 2006. It includes general provisions, requirements and practice, establishment and approval of radio-diagnosis and radiotherapy services, safeguards and quality assurance, and so on. There are a series of radiological protection standards and quality control standards in diagnostic radiology, including 'radiological protection standard for the examination in X-ray diagnosis', 'radiological health protection standards for X-ray examination of child-bearing age women and pregnant women', 'radiological protection standards for the children in X-ray diagnosis', 'standards for radiological protection in medical X-ray diagnosis', 'specification for radiological protection monitoring in medical X-ray diagnosis', 'guide for reasonable application of medical X-ray diagnosis', 'general aspects for quality assurance in medical X-ray image of diagnosis', 'specification of image quality control test for the medical X-ray diagnostic equipment', 'specification of image quality assurance test for X-ray equipment for computed tomography', 'specification for testing of quality control in computed radiography (CR)' and 'specification for testing of quality control in X-ray mammography'. With the X-ray diagnostic equipment, there are acceptant tests, status tests and routing tests in large hospitals. It is poor for routing test in middle and smaller hospitals. CT is used widely in diagnostic radiology, however most workers in CT

  4. Quality control procedures of dental diagnostic radiology systems

    International Nuclear Information System (INIS)

    This work presents quality control reference procedures for dental diagnostic radiology systems, following the recommendations of the Publication 453 of the Brazilian Health Ministry (PF453), to be applied in dental clinics, in order to achieve an improvement in the radiological image qualities and the patient dose reduction. All tests were applied in an intraoral X rays system, following the methodology developed and the requirements of the PF 453. In order to verify the best quality of the image in relation to the smaller exposition time an object test was also developed in this work. The use of this object allowed the reduction of the exposition time of 0.5 seconds, the maximum value of the linear region of the characteristic curve, for 0.2 seconds. The tested X rays system showed a very good agreement with the applied procedures, detaching the reduction of the skin entrance dose using the film-holding devices. However, the size of the field increased and exceeded the maximum value of 6 cm recommended in the standard. The importance of the quality control in dental diagnostic radiology systems is essential due to the constant use of X radiation in dental clinics. The PF453 recommends the frequency of at least two years for the constancy tests. However, it is suggested that the professional, surgeon-dentist, should be responsible for the internal control of the image quality obtained from the X rays device. This can be done through monthly exposures of the object test developed in this work. (author)

  5. Quality Control for Expanded Tsetse Production, Sterilization and Field Application

    International Nuclear Information System (INIS)

    The use of the sterile insect technique (SIT) for the control of pest insects as part of an integrated, area-wide approach is widely accepted. Its application for the eradication of different tsetse flies, the vectors of human sleeping sickness and African animal trypanosomosis, is attracting increasing interest. Following several initial demonstrations of the application of the SIT for tsetse control the technique was applied on the island of Unguja, Zanzibar, in the mid-1990s and, as the final component of an integrated control programme, led to the eradication of the only tsetse species on the island, Glossina austeni. This successful programme encouraged a number of countries to embark on projects with an SIT component for tsetse control, most Ethiopia. In 2001 the Pan African Tsetse and Trypanosomosis Eradication Campaign (PATTEC) was launched by the Organization of African Unity (now African Union, AU) and, subsequently, six countries obtained funding from the African Development Bank (AfDB) in 2005 to support control programmes with an SIT component. A further six countries have subsequently requested AfDB funding for their programmes. The FAO/IAEA coordinated research project (CRP) on Automation for Tsetse Mass Rearing For Use in Sterile Insect Technique Programmes, which was completed in 2001, led to the development of a semi-automated system for tsetse production. Using this new system, a large rearing facility was established in Addis Ababa, Ethiopia, to supply sterile males for an elimination programme in the southern Rift Valley. The development of large-scale rearing highlighted the need for improved quality control procedures and, with this in mind, the Joint FAO/IAEA Division of Nuclear Techniques in Food and Agriculture established a CRP in 2003 entitled Improved and Harmonized Quality Control for Expanded Tsetse Production, Sterilization and Field Application with the Objective of Improving and Expanding the Quality Control Sections of the FAO

  6. Quality Assurance and Quality Control of veal calf residue control programmes for clenbuterol in the Netherlands

    NARCIS (Netherlands)

    Bos M; Ginkel LA van; Stephany RW; ARO

    1995-01-01

    Dit rapport beschrijft de resultaten van een kwaliteitsprogramma voor de analyses van biologische monsters op de aanwezigheid van residuen van beta-agonisten gericht op de bepaling van clenbuterol. Vier Nederlandse laboratoria, waarvan drie deelnemen aan het officiele Nationale Residu Controle P

  7. Quality control in digital mammography: the noise components

    Energy Technology Data Exchange (ETDEWEB)

    Leyton, Fernando [Universidade de Tarapaca, Arica (Chile). Centro de Estudios en Ciencias Radiologicas; Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Nogueira, Maria do Socorro, E-mail: mnogue@cdtn.b [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Duran, Maria Paz [Clinica Alemana, Santiago (Chile). Dept. de Radiologia; Dantas, Marcelino, E-mail: marcelino@inb.gov.b [Industrias Nucleares do Brasil (INB), Caldas, MG (Brazil). Unidade de Tratamento de Minerios; Ubeda, Carlos, E-mail: cubeda@uta.c [Universidade de Tarapaca, Arica (Chile). Fac. de Ciencias de la Salud

    2011-07-01

    To measure the linearity of the detector and determine the noise components (quantum, electronic and structural noise) that contributed to losing image quality and to determine the signal noise ratio (SNR) and contrast noise ratio (CNR). This paper describes the results of the implementation of a protocol for quality control in digital mammography performed in two direct digital mammography equipment (Hologic, Selenia) in Santiago of Chile. Shows the results of linearity and noise analysis of the images which establishes the main cause of noise in the image of the mammogram to ensure the quality and optimize procedures. The study evaluated two digital mammography's Selenia, Hologic (DR) from Santiago, Chile. We conducted the assessment of linearity of the detector, the signal noise ratio, contrast noise ratio and was determined the contribution of different noise components (quantum, electronics and structural noise). Used different thicknesses used in clinical practice according to the protocol for quality control in digital mammography of Spanish society of medical physics and NHSBSP Equipment Report 0604 Version 3. The Selenia mammography software was used for the analysis of images and Unfors Xi detector for measuring doses. The mammography detector has a linear performance, the CNR and SNR did not comply with the Protocol for the thicknesses of 60 and 70 mm. The main contribution of the noise corresponds to the quantum noise, therefore it is necessary to adjust and optimize the mammography system. (author)

  8. Viral Evasion and Manipulation of Host RNA Quality Control Pathways.

    Science.gov (United States)

    Hogg, J Robert

    2016-08-15

    Viruses have evolved diverse strategies to maximize the functional and coding capacities of their genetic material. Individual viral RNAs are often used as substrates for both replication and translation and can contain multiple, sometimes overlapping open reading frames. Further, viral RNAs engage in a wide variety of interactions with both host and viral proteins to modify the activities of important cellular factors and direct their own trafficking, packaging, localization, stability, and translation. However, adaptations increasing the information density of small viral genomes can have unintended consequences. In particular, viral RNAs have developed features that mark them as potential targets of host RNA quality control pathways. This minireview focuses on ways in which viral RNAs run afoul of the cellular mRNA quality control and decay machinery, as well as on strategies developed by viruses to circumvent or exploit cellular mRNA surveillance. PMID:27226372

  9. Sap flow sensors: construction, quality control and comparison.

    Science.gov (United States)

    Davis, Tyler W; Kuo, Chen-Min; Liang, Xu; Yu, Pao-Shan

    2012-01-01

    This work provides a design for two types of sensors, based on the thermal dissipation and heat ratio methods of sap flow calculation, for moderate to large scale deployments for the purpose of monitoring tree transpiration. These designs include a procedure for making these sensors, a quality control method for the final products, and a complete list of components with vendors and pricing information. Both sensor designs were field tested alongside a commercial sap flow sensor to assess their performance and show the importance for quality controlling the sensor outputs. Results show that for roughly 2% of the cost of commercial sensors, self-made sap flow sensors can provide acceptable estimates of the sap flow measurements compared to the commercial sensors.

  10. Quality control in nuclear fuel fabrication on the inspection basis

    International Nuclear Information System (INIS)

    Every plant productive of electric power requires the use of energetics for the transformation to electricity. In the nucleo electric plant the energetic is the uranium, in which it makes ensembles and is used as fuel in the reactor. To assure that the fuel ensembles fulfill the specifications and requirements of design stipulated in the nucleo electric plant is that under a quality control through inspections during the fabrication process. The purpose of this work is to study and verify that the lineaments of the standard 10 CFR 50 appendix B 'Quality assurement for nuclear plants' specially in the criteria 'Inspections' that is used to guarantee the quality of the ensembles. This standard is the one that rules every activity and operation inside the pilot plant and its established in the quality program in the production of nuclear fuel for the Laguna Verde plant. The quality of the assemble is verified through each one of the tests or inspections due to the importance of it in the fabrication of fuel. (Author)

  11. MAGNETIC RESONANCE IMAGING TECHNOLOGY FOR PROCESS CONTROL AND QUALITY MAINTENANCE IN FOOD QUALITY OPERATION

    Directory of Open Access Journals (Sweden)

    S.Divya

    2012-12-01

    Full Text Available This paper investigates the process optimization of various food processing methods such as drying, freezing, freeze drying, extrusion, rehydration of liquid foods, slurries, and suspensions, drypowders and baked products etc., which is an essential step in the optimization of many food manufacturing processes. This article will discuss about the quality factor associated with cellular tissueand also in chocolates. And also this article will give an idea about the on-line MRI for process control and quality assurance in the food processing operations and controlling the quality parameters and actas on-line sensors in quality control of intermediate or final products. The single magnet design and NMR protocol will differ for various applications and it is necessary to adapt a spectrometer operation to each specific application. Magnetic Resonance Imaging (MRI is an emerging technology in foods, and it allows the interior of the food to be imaged noninvasively and non- destructively. These images can then be quantified to yield information about several process and material properties ranging from the composition of a material to the physical structure of the material. The signal detected by a MRI machine varies depending on water content and local magnetic properties of a particular material. Different substances can be distinguished from one another in the study image. This technology provides a real time internal process control for the food industry. This article will also discuss about the various techniques such as solid – imaging techniques for quality check of dried-food products and functional imaging techniques for optimizing the food crops in the field using MRI technology.

  12. Quality control standards for the roots of Three Plumbago species

    Directory of Open Access Journals (Sweden)

    Ariyanathan S

    2010-01-01

    Full Text Available Physicochemical parameters of roots of three Plumbago species, Plumbago capensis, P. rosea and P. zeylanica belonging to Plumbaginaceae were analyzed. Microbial contamination, aflatoxins, pesticide residue and heavy metal content were also determined. Attempt has also been made to estimate the biologically active chemical plumbagin present in them and the data compared. The study ensures that the quality control parameters do help in the proper standardization of the crude drugs in drug development process for global acceptance.

  13. Quality Control Standards for the Roots of Three Plumbago Species

    OpenAIRE

    S. Ariyanathan; Saraswathy, A.; G.V. Rajamanickam

    2010-01-01

    Physicochemical parameters of roots of three Plumbago species, Plumbago capensis, P. rosea and P. zeylanica belonging to Plumbaginaceae were analyzed. Microbial contamination, aflatoxins, pesticide residue and heavy metal content were also determined. Attempt has also been made to estimate the biologically active chemical plumbagin present in them and the data compared. The study ensures that the quality control parameters do help in the proper standardization of the crude drugs in drug devel...

  14. AMAZON RAINFOREST COSMETICS: CHEMICAL APPROACH FOR QUALITY CONTROL

    OpenAIRE

    Mariko Funasaki; Hileia dos Santos Barroso; Valdelira Lia Araújo Fernandes; Ingrid Sabino Menezes

    2016-01-01

    The market for natural cosmetics featuring ingredients derived from Amazon natural resources is growing worldwide. However, there is neither enough scientific basis nor quality control of these ingredients. This paper is an account of the chemical constituents and their biological activities of fourteen Amazonian species used in cosmetic industry, including açaí (Euterpe oleracea), andiroba (Carapa guianensis), bacuri (Platonia insignis), Brazil nut (Bertholletia excelsa), buriti (Mauritia vi...

  15. Electronic Nose for Microbiological Quality Control of Food Products

    OpenAIRE

    M. Falasconi; Concina, I.; Gobbi, E; V. Sberveglieri; Pulvirenti, A.; Sberveglieri, G.

    2012-01-01

    Electronic noses (ENs) have recently emerged as valuable candidates in various areas of food quality control and traceability, including microbial contamination diagnosis. In this paper, the EN technology for microbiological screening of food products is reviewed. Four paradigmatic and diverse case studies are presented: (a) Alicyclobacillus spp. spoilage of fruit juices, (b) early detection of microbial contamination in processed tomatoes, (c) screening of fungal and fumonisin contamination ...

  16. Protecting the proteome: Eukaryotic cotranslational quality control pathways

    OpenAIRE

    Lykke-Andersen, Jens; Bennett, Eric J.

    2014-01-01

    The correct decoding of messenger RNAs (mRNAs) into proteins is an essential cellular task. The translational process is monitored by several quality control (QC) mechanisms that recognize defective translation complexes in which ribosomes are stalled on substrate mRNAs. Stalled translation complexes occur when defects in the mRNA template, the translation machinery, or the nascent polypeptide arrest the ribosome during translation elongation or termination. These QC events promote the disass...

  17. Automated quality control for genome wide association studies

    Science.gov (United States)

    Ellingson, Sally R.; Fardo, David W.

    2016-01-01

    This paper provides details on the necessary steps to assess and control data in genome wide association studies (GWAS) using genotype information on a large number of genetic markers for large number of individuals. Due to varied study designs and genotyping platforms between multiple sites/projects as well as potential genotyping errors, it is important to ensure high quality data. Scripts and directions are provided to facilitate others in this process.

  18. Endoplasmic Reticulum-Mediated Protein Quality Control in Arabidopsis

    OpenAIRE

    Jianming eLi; Yidan eLiu

    2014-01-01

    A correct three-dimensional structure is crucial for the physiological functions of a protein, yet the folding of proteins to acquire native conformation is a fundamentally error-prone process. Eukaryotic organisms have evolved a highly conserved endoplasmic reticulum-mediated protein quality control (ERQC) mechanism to monitor folding processes of secretory and membrane proteins, allowing export of only correctly folded proteins to their physiological destinations, retaining incompletely/mis...

  19. QUALITY CONTROL ON THE AUSTENITIC-BAINITIC DUCTILE IRON GEAR

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    By reasonable casting, spheroidizing , inoculating and heat treating processes to control cupola metallurgy and the lipuid iron chemical compositions, a new kind of austenitic-bainitic ductile iron which can substitute for 20CrMnTi carburizing steel is studied. The gears made by the cast iron are high in quality,low in weight and the production cost is greatly reduced. The mechanical properties of the gear, including wear resistance, fatigue resistance, durability and others, can be greatly improved.

  20. Quality Control of Coffee Using an Electronic Nose System

    Directory of Open Access Journals (Sweden)

    Nidal F. Shilbayeh

    2004-01-01

    Full Text Available An electronic nose system for quality control of coffee is designed and tested. The system uses the Figaro TGS800 series sensors with an integrated heating element. The testing of the system is carried out using different types of coffee where it is proved successful in classifying the tested coffees and actual discrimination of ingredients into different classes[10]. Database based software is designed to interface the built hardware and to process the electronic nose signals before being classified.

  1. Quality Control and Dosimetry in Mammographic Units in Greece

    International Nuclear Information System (INIS)

    Quality control measurements have been carried out on 29 mammographic units. It was found that a large percentage of users obtained Optical Densities outside the recommended values. Resolution under routine conditions was below the limit of 14 lp/mm in about 50% of the units. The skin entrance dose was in a few cases in excess of 10 micro Gray, but the mean value was well below this upper limit. Analysis of the results obtained has indicated that proper calibration of kilo voltage panel indications and automatic exposure control systems is of outmost importance and should be performed regularly. (authors)

  2. Automated quality control in a file-based broadcasting workflow

    Science.gov (United States)

    Zhang, Lina

    2014-04-01

    Benefit from the development of information and internet technologies, television broadcasting is transforming from inefficient tape-based production and distribution to integrated file-based workflows. However, no matter how many changes have took place, successful broadcasting still depends on the ability to deliver a consistent high quality signal to the audiences. After the transition from tape to file, traditional methods of manual quality control (QC) become inadequate, subjective, and inefficient. Based on China Central Television's full file-based workflow in the new site, this paper introduces an automated quality control test system for accurate detection of hidden troubles in media contents. It discusses the system framework and workflow control when the automated QC is added. It puts forward a QC criterion and brings forth a QC software followed this criterion. It also does some experiments on QC speed by adopting parallel processing and distributed computing. The performance of the test system shows that the adoption of automated QC can make the production effective and efficient, and help the station to achieve a competitive advantage in the media market.

  3. Run-to-run product quality control of batch processes

    Institute of Scientific and Technical Information of China (English)

    JIA Li; SHI Ji-ping; CHENG Da-shuai; CHIU Min-sen

    2009-01-01

    Batch processes have been increasingly used in the production of low volume and high value added products.Consequently,optimization control in batch processes is crucial in order to derive the maximum benefit.In this paper,a run-to-run product quality control based on iterative learning optimization control is developed.Moreover,a rigorous theorem is proposed and proven in this paper,which states that the tracking error under the optimal iterative learning control (ILC) law can converge to zero.In this paper,a typical nonlinear batch continuous stirred tank reactor (CSTR) is considered,and the results show that the performance of trajectory tracking is gradually improved by the ILC.

  4. QUALITY CONTROL OF SEMICONDUCTOR PACKAGING BASED ON PRINCIPAL COMPONENTS ANALYSIS

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    5 critical quality characteristics must be controlled in the surface mount and wire-bond process in semiconductor packaging. And these characteristics are correlated with each other. So the principal components analysis(PCA) is used in the analysis of the sample data firstly. And then the process is controlled with hotelling T2 control chart for the first several principal components which contain sufficient information. Furthermore, a software tool is developed for this kind of problems. And with sample data from a surface mounting device(SMD) process, it is demonstrated that the T2 control chart with PCA gets the same conclusion as without PCA, but the problem is transformed from high-dimensional one to a lower dimensional one, i.e., from 5 to 2 in this demonstration.

  5. [Controllability pyramid: an integrated control system of quality for traditional Chinese medicines].

    Science.gov (United States)

    Xiao, Xiao-He; Zhang, Ding-Kun; Wang, Jia-Bo; Yang, Ming; Peng, Cheng

    2015-01-01

    Quality control is one of the key scientific tissues in the modernization of traditional Chinese medicines (TCM). In order to overcome the deficiencies of assessment indexes, including little systematization and quantification, as well as loose association with clinical efficacy and dosage, a new integrated method named controllability pyramid ( CP) is first proposed in this paper. In addition, some study cases are used to explain how this model is constructed. We hope the establishment of CP could promote the clinical-orien- ted integrated innovation research of TCM, and provide control strategy and technology examples for improving the quality of Chinese medicines and clinical efficacy.

  6. Complement analysis 2016: Clinical indications, laboratory diagnostics and quality control.

    Science.gov (United States)

    Prohászka, Zoltán; Nilsson, Bo; Frazer-Abel, Ashley; Kirschfink, Michael

    2016-11-01

    In recent years, complement analysis of body fluids and biopsies, going far beyond C3 and C4, has significantly enhanced our understanding of the disease process. Such expanded complement analysis allows for a more precise differential diagnosis and for critical monitoring of complement-targeted therapy. These changes are a result of the growing understanding of the involvement of complement in a diverse set of disorders. To appreciate the importance of proper complement analysis, it is important to understand the role it plays in disease. Historically, it was the absence of complement as manifested in severe infection that was noted. Since then complement has been connected to a variety of inflammatory disorders, such as autoimmune diseases and hereditary angioedema. While the role of complement in the rejection of renal grafts has been known longer, the significant impact of complement. In certain nephropathies has now led to the reclassification of some rare kidney diseases and an increased role for complement analysis in diagnosis. Even more unexpected is that complement has also been implicated in neural, ophtalmological and dermatological disorders. With this level of involvement in some varied and impactful health issues proper complement testing is clearly important; however, analysis of the complement system varies widely among laboratories. Except for a few proteins, such as C3 and C4, there are neither well-characterized standard preparations nor calibrated assays available. This is especially true for the inter-laboratory variation of tests which assess classical, alternative, or lectin pathway function. In addition, there is a need for the standardization of the measurement of complement activation products that are so critical in determining whether clinically relevant complement activation has occurred in vivo. Finally, autoantibodies to complement proteins (e.g. anti-C1q), C3 and C4 convertases (C3 and C4 nephritic factor) or to regulatory proteins

  7. Complement analysis 2016: Clinical indications, laboratory diagnostics and quality control.

    Science.gov (United States)

    Prohászka, Zoltán; Nilsson, Bo; Frazer-Abel, Ashley; Kirschfink, Michael

    2016-11-01

    In recent years, complement analysis of body fluids and biopsies, going far beyond C3 and C4, has significantly enhanced our understanding of the disease process. Such expanded complement analysis allows for a more precise differential diagnosis and for critical monitoring of complement-targeted therapy. These changes are a result of the growing understanding of the involvement of complement in a diverse set of disorders. To appreciate the importance of proper complement analysis, it is important to understand the role it plays in disease. Historically, it was the absence of complement as manifested in severe infection that was noted. Since then complement has been connected to a variety of inflammatory disorders, such as autoimmune diseases and hereditary angioedema. While the role of complement in the rejection of renal grafts has been known longer, the significant impact of complement. In certain nephropathies has now led to the reclassification of some rare kidney diseases and an increased role for complement analysis in diagnosis. Even more unexpected is that complement has also been implicated in neural, ophtalmological and dermatological disorders. With this level of involvement in some varied and impactful health issues proper complement testing is clearly important; however, analysis of the complement system varies widely among laboratories. Except for a few proteins, such as C3 and C4, there are neither well-characterized standard preparations nor calibrated assays available. This is especially true for the inter-laboratory variation of tests which assess classical, alternative, or lectin pathway function. In addition, there is a need for the standardization of the measurement of complement activation products that are so critical in determining whether clinically relevant complement activation has occurred in vivo. Finally, autoantibodies to complement proteins (e.g. anti-C1q), C3 and C4 convertases (C3 and C4 nephritic factor) or to regulatory proteins

  8. Austrian Daily Climate Data Rescue and Quality Control

    Science.gov (United States)

    Jurkovic, A.; Lipa, W.; Adler, S.; Albenberger, J.; Lechner, W.; Swietli, R.; Vossberg, I.; Zehetner, S.

    2010-09-01

    Checked climate datasets are a "conditio sine qua non" for all projects that are relevant for environment and climate. In the framework of climate change studies and analysis it is essential to work with quality controlled and trustful data. Furthermore these datasets are used as input for various simulation models. In regard to investigations of extreme events, like strong precipitation periods, drought periods and similar ones we need climate data in high temporal resolution (at least in daily resolution). Because of the historical background - during Second World War the majority of our climate sheets were sent to Berlin, where the historical sheets were destroyed by a bomb attack and so important information got lost - only several climate sheets, mostly duplicates, before 1939 are available and stored in our climate data archive. In 1970 the Central Institute for Meteorology and Geodynamics in Vienna started a first attempt to digitize climate data by means of punch cards. With the introduction of a routinely climate data quality control in 1984 we can speak of high-class-checked daily data (finally checked data, quality flag 6). Our group is working on the processing of digitization and quality control of the historical data for the period 1872 to 1983 for 18 years. Since 2007 it was possible to intensify the work (processes) in the framework of an internal project, namely Austrian Climate Data Rescue and Quality Control. The aim of this initiative was - and still is - to supply daily data in an outstanding good and uniform quality. So this project is a kind of pre-project for all scientific projects which are working with daily data. In addition to routine quality checks (that are running since 1984) using the commercial Bull Software we are testing our data with additional open source software, namely ProClim.db. By the use of this spatial and statistical test procedure, the elements air temperature and precipitation - for several sites in Carinthia - could

  9. Retrospective exposure assessment and quality control in an international multi-centre case-control study

    DEFF Research Database (Denmark)

    Tinnerberg, H; Heikkilä, P; Huici-Montagud, A;

    2003-01-01

    to the original CA studies at the time of CA testing, but not for the whole work life. An independent occupational hygienist coordinated harmonization of the assessment criteria and the quality control procedure. The reliability of the exposure assessments was calculated as deviation from the majority......The paper presents the exposure assessment method and quality control procedure used in an international, multi-centre case-control study within a joint Nordic and Italian cohort. This study was conducted to evaluate whether occupational exposure to carcinogens influenced the predictivity of high...... was higher among the original assessors (the assessor from the same country as the subject) than the average prevalence assessed by the other four in the quality control round. The original assessors classified more job situations as exposed than the others. Several reasons for this are plausible: real...

  10. Quality control of the RMS US flood model

    Science.gov (United States)

    Jankowfsky, Sonja; Hilberts, Arno; Mortgat, Chris; Li, Shuangcai; Rafique, Farhat; Rajesh, Edida; Xu, Na; Mei, Yi; Tillmanns, Stephan; Yang, Yang; Tian, Ye; Mathur, Prince; Kulkarni, Anand; Kumaresh, Bharadwaj Anna; Chaudhuri, Chiranjib; Saini, Vishal

    2016-04-01

    The RMS US flood model predicts the flood risk in the US with a 30 m resolution for different return periods. The model is designed for the insurance industry to estimate the cost of flood risk for a given location. Different statistical, hydrological and hydraulic models are combined to develop the flood maps for different return periods. A rainfall-runoff and routing model, calibrated with observed discharge data, is run with 10 000 years of stochastic simulated precipitation to create time series of discharge and surface runoff. The 100, 250 and 500 year events are extracted from these time series as forcing for a two-dimensional pluvial and fluvial inundation model. The coupling of all the different models which are run on the large area of the US implies a certain amount of uncertainty. Therefore, special attention is paid to the final quality control of the flood maps. First of all, a thorough quality analysis of the Digital Terrain model and the river network was done, as the final quality of the flood maps depends heavily on the DTM quality. Secondly, the simulated 100 year discharge in the major river network (600 000 km) is compared to the 100 year discharge derived using extreme value distribution of all USGS gauges with more than 20 years of peak values (around 11 000 gauges). Thirdly, for each gauge the modelled flood depth is compared to the depth derived from the USGS rating curves. Fourthly, the modelled flood depth is compared to the base flood elevation given in the FEMA flood maps. Fifthly, the flood extent is compared to the FEMA flood extent. Then, for historic events we compare flood extents and flood depths at given locations. Finally, all the data and spatial layers are uploaded on geoserver to facilitate the manual investigation of outliers. The feedback from the quality control is used to improve the model and estimate its uncertainty.

  11. Online Error Reporting for Managing Quality Control Within Radiology.

    Science.gov (United States)

    Golnari, Pedram; Forsberg, Daniel; Rosipko, Beverly; Sunshine, Jeffrey L

    2016-06-01

    Information technology systems within health care, such as picture archiving and communication system (PACS) in radiology, can have a positive impact on production but can also risk compromising quality. The widespread use of PACS has removed the previous feedback loop between radiologists and technologists. Instead of direct communication of quality discrepancies found for an examination, the radiologist submitted a paper-based quality-control report. A web-based issue-reporting tool can help restore some of the feedback loop and also provide possibilities for more detailed analysis of submitted errors. The purpose of this study was to evaluate the hypothesis that data from use of an online error reporting software for quality control can focus our efforts within our department. For the 372,258 radiologic examinations conducted during the 6-month period study, 930 errors (390 exam protocol, 390 exam validation, and 150 exam technique) were submitted, corresponding to an error rate of 0.25 %. Within the category exam protocol, technologist documentation had the highest number of submitted errors in ultrasonography (77 errors [44 %]), while imaging protocol errors were the highest subtype error for computed tomography modality (35 errors [18 %]). Positioning and incorrect accession had the highest errors in the exam technique and exam validation error category, respectively, for nearly all of the modalities. An error rate less than 1 % could signify a system with a very high quality; however, a more likely explanation is that not all errors were detected or reported. Furthermore, staff reception of the error reporting system could also affect the reporting rate. PMID:26510753

  12. Quality control for some digital fluoroscopy equipment used in Sudan

    International Nuclear Information System (INIS)

    The aim of this work was to perform quality control (QC) for six digital fluoroscopy units used for cardiovascular and interventional radiology procedures. Measurement were based on the QC protocol developed in the framework of European Commission (EU) DIMOND111 project. Measurement made included: beam quality (half-value layer, HVL), peak tube voltage (kVp) accuracy, automatic exposure control (Aec) and patient dose in terms of entrance surface air kerma rate plus image intensifier input air kerma rate. Dose measurements were made using Calibrated dose rate meter. Field limitation and source to skin distant measurement in addition to evaluation radiation protection tools for occupation exposure were performed. Image quality was evaluated in terms of spatial resolution and Contrast detail detectability. Patient dose measurements was performed using polymethylmethacrylate (PMMA) patient equivalent phantom whereas image quality was assessed using Haunter Type 53 spatial frequency grating and TO10 contrast detail phantom. The results show that the measured HVL and peak tube voltage were within the recommended limits of 10% in four fluoroscopy units. Entrance surface air kerma rate measured ranged from 6.1 to 250 mGy/min for fluoroscopy units operated in pulsed, continuous and cine mode of operation. These results were obtained using varying thicknesses of PMMA phantom. Most values are in reasonable agreement with internationally established reference levels with exception to one fluoroscopy unit where doses were remarkably high. Field limitation and minimum source to skin distance were well within the recommended limits of 30 cm for all fluoroscopy units. The limiting resolution was ranged from 1.0 to 2.2 Lp /mm for image intensifier field diameters between 7 ad 23 cm. The results of present study can be used as baseline for future quality assurance measurements. (Author)

  13. 40 CFR 81.75 - Metropolitan Charlotte Interstate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.75 Metropolitan Charlotte Interstate Air Quality Control Region. The Metropolitan Charlotte Interstate Air Quality Control Region (North Carolina-South Carolina) has been...

  14. 40 CFR 81.23 - Southwest Pennsylvania Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.23 Southwest Pennsylvania Intrastate Air Quality Control Region. The Southwest Pennsylvania Intrastate Air Quality Control Region is redesignated to consist of the...

  15. 40 CFR 81.20 - Metropolitan Cincinnati Interstate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.20 Metropolitan Cincinnati Interstate Air Quality Control Region. The Metropolitan Cincinnati Interstate Air Quality Control Region (Ohio-Kentucky-Indiana) is revised to consist...

  16. 40 CFR 81.24 - Niagara Frontier Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.24 Niagara Frontier Intrastate Air Quality Control Region. The Niagara Frontier Intrastate Air Quality Control Region (New York) consists of the territorial...

  17. 40 CFR 81.14 - Metropolitan Chicago Interstate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.14 Metropolitan Chicago Interstate Air Quality Control Region. The Metropolitan Chicago Interstate Air Quality Control Region (Illinois-Indiana) is revised to consist of...

  18. 40 CFR 81.48 - Champlain Valley Interstate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.48 Champlain Valley Interstate Air Quality Control Region. The Champlain Valley Interstate Air Quality Control Region (Vermont-New York) has been revised to consist of...

  19. 40 CFR 81.16 - Metropolitan Denver Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.16 Metropolitan Denver Intrastate Air Quality Control Region. The Metropolitan Denver Intrastate Air Quality Control Region (Colorado) consists of the territorial...

  20. 40 CFR 81.45 - Metropolitan Atlanta Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.45 Metropolitan Atlanta Intrastate Air Quality Control Region. The Metropolitan Atlanta Intrastate Air Quality Control Region (Georgia) has been revised to consist of...

  1. 40 CFR 81.41 - Metropolitan Birmingham Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.41 Metropolitan Birmingham Intrastate Air Quality Control Region. The Metropolitan Birmingham Intrastate Air Quality Control Region (Alabama) has been revised to consist of...

  2. 40 CFR 81.47 - Central Oklahoma Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.47 Central Oklahoma Intrastate Air Quality Control Region. The Metropolitan Oklahoma Intrastate Air Quality Control Region has been renamed the Central Oklahoma...

  3. 40 CFR 81.59 - Cumberland-Keyser Interstate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.59 Cumberland-Keyser Interstate Air Quality Control Region. The Cumberland-Keyser Interstate Air Quality Control Region (Maryland-West Virginia) has been revised to...

  4. 40 CFR 81.34 - Metropolitan Dayton Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.34 Metropolitan Dayton Intrastate Air Quality Control Region. The Metropolitan Dayton Intrastate Air Quality Control Region consists of the territorial area encompassed by...

  5. 40 CFR 81.43 - Metropolitan Toledo Interstate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.43 Metropolitan Toledo Interstate Air Quality Control Region. The Metropolitan Toledo Interstate Air Quality Control Region (Ohio-Michigan) consists of the territorial...

  6. 40 CFR 81.49 - Southeast Florida Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.49 Southeast Florida Intrastate Air Quality Control Region. The Southeast Florida Intrastate Air Quality Control Region is redesignated to consist of the territorial...

  7. 40 CFR 81.28 - Metropolitan Baltimore Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.28 Metropolitan Baltimore Intrastate Air Quality Control Region. The Metropolitan Baltimore Intrastate Air Quality Control Region (Maryland) consists of the territorial...

  8. 40 CFR 81.19 - Metropolitan Boston Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.19 Metropolitan Boston Intrastate Air Quality Control Region. The Metropolitan Boston Intrastate Air Quality Control Region (Massachusetts) consists of the territorial...

  9. 40 CFR 81.44 - Metropolitan Memphis Interstate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.44 Metropolitan Memphis Interstate Air Quality Control Region. The Metropolitan Memphis Interstate Air Quality Control Region (Arkansas-Mississippi-Tennessee) consists of...

  10. 40 CFR 81.76 - State of Hawaii Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 17 2010-07-01 2010-07-01 false State of Hawaii Air Quality Control... PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.76 State of Hawaii Air Quality Control Region. The State of Hawaii Air...

  11. 40 CFR 81.62 - Northeast Mississippi Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.62 Northeast Mississippi Intrastate Air Quality Control Region. The Alabama-Mississippi-Tennessee Interstate Air Quality Control Region has been renamed the...

  12. 40 CFR 81.30 - Southeastern Wisconsin Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.30 Southeastern Wisconsin Intrastate Air Quality Control Region. The Metropolitan Milwaukee Intrastate Air Quality Control Region (Wisconsin) has been renamed the...

  13. 40 CFR 81.31 - Metropolitan Providence Interstate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.31 Metropolitan Providence Interstate Air Quality Control Region. The Metropolitan Providence Interstate Air Quality Control Region (Rhode Island-Massachusetts) consists of...

  14. Radiation protection of patients and quality controls in teleradiology

    Energy Technology Data Exchange (ETDEWEB)

    Vermiglio, G.; Testagrossa, B.; Sansotta, C.; Tripepi, M.G. [Messina Univ., Dept. of Protezionistica Ambientale, Sanitaria, Sociale ed Industriale (Italy)

    2006-07-01

    Nowadays, it is well-known that tele-radiology represents the new frontier of radiodiagnostic imaging. In this case, the continuous broadening of transmission bands and the more sophisticated procedures of information packaging constitute a no negligible inducement. Moreover, standards used to convert analogical signals into the digital ones, necessary to transfer via ether radiological images and information, involve a more limited loss of information. Nevertheless, unlike the common images, in case of the X-ray diagnostic images it must take into account that the EURATOM Council Directives give the health physicist all the procedures to be followed for checking the status of X-ray equipments. In particular, the EURATOM Council Directives provide minimum criteria of acceptance for parameters that characterised the correct working of the radiological equipments and the guide lines for standardised execution of X-ray images, in order to obtain high quality information. In addiction, for maintaining such level it is necessary to adopt adequate programs of Quality Assurance. Naturally, the high quality of radiological images must be conserved after the transmission of information. So, in order to evaluate the amount of losses that can be introduced after transferring the X-ray images from source to user, the authors have carried out specific procedures in order to evaluate the quality level of the images after transmission and to compare them with the correspondent ones acquired at the equipment console. To this aim, the AAs have identified all the parameters able to verify the quality level of the images and measured the values obtained for the directly acquired images and the transferred ones. They have also considered different kinds of transmission protocols to define suitable procedures of remote quality controls. (authors)

  15. Radiation protection of patients and quality controls in teleradiology

    International Nuclear Information System (INIS)

    Nowadays, it is well-known that tele-radiology represents the new frontier of radiodiagnostic imaging. In this case, the continuous broadening of transmission bands and the more sophisticated procedures of information packaging constitute a no negligible inducement. Moreover, standards used to convert analogical signals into the digital ones, necessary to transfer via ether radiological images and information, involve a more limited loss of information. Nevertheless, unlike the common images, in case of the X-ray diagnostic images it must take into account that the EURATOM Council Directives give the health physicist all the procedures to be followed for checking the status of X-ray equipments. In particular, the EURATOM Council Directives provide minimum criteria of acceptance for parameters that characterised the correct working of the radiological equipments and the guide lines for standardised execution of X-ray images, in order to obtain high quality information. In addiction, for maintaining such level it is necessary to adopt adequate programs of Quality Assurance. Naturally, the high quality of radiological images must be conserved after the transmission of information. So, in order to evaluate the amount of losses that can be introduced after transferring the X-ray images from source to user, the authors have carried out specific procedures in order to evaluate the quality level of the images after transmission and to compare them with the correspondent ones acquired at the equipment console. To this aim, the AAs have identified all the parameters able to verify the quality level of the images and measured the values obtained for the directly acquired images and the transferred ones. They have also considered different kinds of transmission protocols to define suitable procedures of remote quality controls. (authors)

  16. The consistency approach for quality control of vaccines - a strategy to improve quality control and implement 3Rs.

    Science.gov (United States)

    De Mattia, Fabrizio; Chapsal, Jean-Michel; Descamps, Johan; Halder, Marlies; Jarrett, Nicholas; Kross, Imke; Mortiaux, Frederic; Ponsar, Cecile; Redhead, Keith; McKelvie, Jo; Hendriksen, Coenraad

    2011-01-01

    Current batch release testing of established vaccines emphasizes quality control of the final product and is often characterized by extensive use of animals. This report summarises the discussions of a joint ECVAM/EPAA workshop on the applicability of the consistency approach for routine release of human and veterinary vaccines and its potential to reduce animal use. The consistency approach is based upon thorough characterization of the vaccine during development and the principle that the quality of subsequent batches is the consequence of the strict application of a quality system and of a consistent production of batches. The concept of consistency of production is state-of-the-art for new-generation vaccines, where batch release is mainly based on non-animal methods. There is now the opportunity to introduce the approach into established vaccine production, where it has the potential to replace in vivo tests with non-animal tests designed to demonstrate batch quality while maintaining the highest quality standards. The report indicates how this approach may be further developed for application to established human and veterinary vaccines and emphasizes the continuing need for co-ordination and harmonization. It also gives recommendations for work to be undertaken in order to encourage acceptance and implementation of the consistency approach.

  17. Quality Assurance and Quality Control in Point-of-Care Testing.

    Science.gov (United States)

    Newman, Ashleigh W; Behling-Kelly, Erica

    2016-03-01

    With advancements in the standard of care in veterinary medicine and instrument technology, performing in-house laboratory work on a variety of point-of-care instruments, ranging from glucometers to benchtop chemistry analyzers, has become increasingly commonplace. However, the ability of an instrument to perform a test does not guarantee that those results are accurate. Ensuring that your in-clinic laboratory is providing reliable data requires a comprehensive plan that encompasses both common sense practices aimed at preventing errors at each stage of the testing process, as well as standard operating procedures to validate and monitor analyzer performance. These 2 arms of the plan are known as quality assurance and quality control. Although these concepts are typically out of the comfort zone for veterinarians, just as the thought of business management may deter some veterinarians from practice ownership, it is not beyond the capabilities of veterinarians to learn, understand, and incorporate them into their practice. The objectives of this article are to convey the importance of quality assurance and quality control, walk you through the American Society for Veterinary Clinical Pathology guidelines on this topic, and provide direction to additional resources for further education on this topic, all with the focus on point-of-care testing in the in-clinic laboratory. PMID:27451043

  18. Emerging melt quality control solution technologies for aluminium melt

    Institute of Scientific and Technical Information of China (English)

    Arturo Pascual, Jr

    2009-01-01

    The newly developed "MTS 1500" Melt Treatment System is performing the specifically required melt treatment operations like degassing, cleaning, modification and/or grain refinement by an automated process in one step and at the same location. This linked process is saving time, energy and metal losses allowing-by automated dosage of the melt treatment agents-the production of a consistent melt quality batch after batch. By linking the MTS Metal Treatment System with sensors operating on-line in the melt, i.e., with a hydrogen sensor "Alspek H", a fully automated control of parts of the process chain like degassing is possible. This technology does guarantee a pre-specified and documented melt quality in each melt treatment batch. Furthermore, to ensure that castings are consistent and predictable there is a growing realization that critical measuring the cleanliness of an aluminum melt but these can be both slow and costly. A simple, rapid and meaningful method of measuring and bench marking the cleanliness of an aluminum melt has been developed to offer the foundry a practical method of measuring melt cleanliness.This paper shows the structure and performance of the integrated MTS melt treatment process and documents achieved melt quality standards after degassing, cleaning, modification and grain refinement operations under real foundry conditions. It also provides an insight on a melt cleanliness measuring device "Alspek MQ" to provide foundry men better tools in meeting the increasing quality and tighter specification demand from the industry.

  19. Quality control in the commerce of irradiated foods

    International Nuclear Information System (INIS)

    In spite of an irradiated food is innocuous for health and that the irradiation process offers great advantages as conservation and hygiene method and it has been recognised by the Agriculture and Health International organizations and although the adequate equipment exists to make this treatment in the majority of countries, an international trade of irradiated foods has not been established and it is that it has to be required that the quality control of the treatment should be regulated by the corresponding authorities and it also should be harmonized with other countries for the commercial interchange. Owing to up to present an identification method of irradiated foods which is validated, the unique quality control for irradiated foods is realized in the irradiation plant, measuring the absorbed dose in products, using dosimetric systems justly calibrated and standardized to be used the adequate for the type of product and dose level which is wanted to be measured for foods mainly for quarantine treatment which is very important to determine that any part of the irradiation system has reached the minimum dose to obtain the technical effect which is desired and that it does not exceed the maximum dose for that the product quality not to be altered. (Author)

  20. Digital intraoral radiographic quality assurance and control in private practice.

    Science.gov (United States)

    Walker, Timothy F; Mah, Peter; Dove, S Brent; McDavid, W Doss

    2014-01-01

    At present, the American Dental Association and the American Academy of Oral Maxillofacial Radiology have guidelines for the dental environment that include quality assurance and control of film-based radiography. Approximately 19%-30% of US dental offices currently use some form of digital intraoral radiography, and growth is expected to continue. It is anticipated that new tools and guidelines will be needed to aid in the development of quality assurance (QA) and control of digital intraoral radiographic images. Working with a representative sample of private practice dental offices, this study examined and evaluated the entire digital intraoral radiographic system used in each operatory. The X-ray machine was tested for equipment performance and accuracy, and the computer monitor calibration was evaluated and adjusted as needed. The results confirm the continued need for updated QA procedures in the dental office that include digital X-ray imaging. By implementing these changes and practices, dentists should be able to improve the diagnostic quality of radiographs while reducing the radiation exposure of the patient. PMID:25184710

  1. Data quality control in eco-environmental monitoring

    Science.gov (United States)

    Lu, Chunyan; Wang, Jing

    2007-11-01

    With the development of science and technology, a number of environmental issues, such as sustainable development, climate change, environmental pollution, and land degradation become serious. Greater attention has been attached to environmental protection. The government gradually launched some eco--environmental construction projects. In 1999, China begin to carry out the project of Grain-for-Green in the west, to improve the eco-environment, and it make some good effect, but there are some questions that still can not be answered. How about the new grass or forest? Where are they? How can we do in the future? To answer these questions, the government began to monitor the eco-environment, based on remote sensing technology. Geography information can be attained timely, but the issue of uncertainty has become increasingly recognized, and this uncertainty affects the reliability of applications using the data. This article analyzed the process of eco-environment monitoring, the uncertainty of geography information, and discussed the methods of data quality control. The Spot5 span data and multi-spectral data in 2003(2002) were used, combined with land use survey data at the scale of 1:10,000, topography data at the scale of 1:10,000, and the local Grain-for-Green project map. Also the social and economic data were collected. Eco-environmental monitoring is a process which consists of several steps, such as image geometric correction, image matching, information extraction, and so on. Based on visual and automated method, land information turned to grass and forest from cultivated land was obtained by comparing the information form remote sensing data with the land survey data, and local Grain-for-Green project data, combined with field survey. According to the process, the uncertainty in the process was analyzed. Positional uncertainty, attribute uncertainty, and thematic uncertainty was obvious. Positional uncertainty mainly derived from image geometric correction

  2. Gastric tissue biopsy and culture

    Science.gov (United States)

    ... of the belly Black stools Vomiting blood or coffee ground-like material A gastric tissue biopsy and culture can help detect: Cancer Infections, most commonly Helicobacter pylori , the bacteria that can cause stomach ulcers Normal Results A ...

  3. Possibilities of obtaining and controlling high-quality pressure castings

    Directory of Open Access Journals (Sweden)

    S. Pietrowski

    2011-07-01

    Full Text Available The paper presents the influence of the type of furnace charging melting, refining and modification silumins 226 and 231 on the porosity and microstructure of castings. It was shown that in order to reduce or eliminate the porosity of the castings is necessary to the refining ECOSAL-AL113 of liquid silumin both in the melting furnace, and in the ladle and an additional nitrogen, in the heat furnace modified and refining with nitrogen. To control the effects of refining and modifying the TDA method was used. It was found that based on crystal- lization curve can be qualitatively assess the gas porosity of the castings. In order to control and quality control silumins author developed a computer program using the method of TDA, which sets out: Rm, A5, HB and casting porosity P and the concentration of hydrogen in them. The program also informs the technological procedures to be performed for liquid silumin improper preparation.

  4. Testicular biopsy in prepubertal boys

    DEFF Research Database (Denmark)

    Faure, Alice; Bouty, Aurore; O'Brien, Mike;

    2016-01-01

    No consensus exists regarding the precise role of testicular biopsy in prepubertal boys, although it is considered useful for assessing the potential consequences of undescended testes on fertility. Current scientific knowledge indicates that surgeons should broaden indications for this procedure...... preservation of fertility after gonadotoxic chemotherapy - even for prepubertal boys - are emerging. Cryopreservation of testicular tissue samples for the preservation of fertility - although still an experimental method at present - is appealing in this context. In our opinion, testicular biopsy in...

  5. Control of quality in spectrometry gamma of low level

    CERN Document Server

    Salazar, A

    1997-01-01

    Low level gamma spectrometry is a very precise technique to measure the concentration of nuclides present in different samples in Bq kg sup - sup 1. The quality control of the procedure and method used can be carried out by intercomparison exercises with world recognized institutions. During the last three years the Nuclear Physics Laboratory Of The University of Costa Rica (LAFNA) has been participating in the international quality assessment program (QAP) carried out by the Environmental Measurements Laboratory (EML), department of Energy, USA. The results show a very good agreement with the rest of the participant laboratories. This provides a very objective evaluation of the high precision of the methods used by LAFNA in low level spectroscopy measurements. (Author)

  6. Guidebook on quality control of water reactor fuel

    International Nuclear Information System (INIS)

    As a result of the increasing contribution of nuclear power to the world's supply of electrical energy, growing emphasis is being placed on the reliability of nuclear fuel performance. The need to produce a reliable product is based not only on economic reasons but also on safety considerations. Fuel assemblies must withstand the operational requirements placed on them while in the reactor; also, in some cases, they have to be stored for long periods in water-filled basins until they are either reprocessed or ultimately subjected to disposal. One of the keys to consistent and reliable fuel production is an adequate Quality Control (QC) programme, operating under a Quality Assurance (QA) system. In connection with various activities sponsored by the International Atomic Energy Agency it has been suggested for some time that a guidebook should be published, highlighting the role that QC plays in the manufacture of nuclear fuel and stressing the relationship that exists between the QC and QA functions. The aim of this book is to give a summary of the present state of practical experience in the areas of: quality-relevant design requirements; quality control of products and processes. Specific QA requirements are referred to where they are important for an understanding of the co-operation required between the various activities involved in nuclear fuel technology. Examples are also given to illustrate specific needs or specific types of experience in this area. In order to distinguish clearly between the generally required criteria and rules and the details of particular practical experience, the book is divided into two main parts. Part A focuses on the philosophy and principles; Part B supplements Part A with technically detailed descriptions and examples

  7. 21 CFR 111.65 - What are the requirements for quality control operations?

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 2 2010-04-01 2010-04-01 false What are the requirements for quality control... Process Control System § 111.65 What are the requirements for quality control operations? You must implement quality control operations in your manufacturing, packaging, labeling, and holding operations...

  8. CASE STUDY ON WATER QUALITY CONTROL IN AN AQUAPONIC SYSTEM

    Directory of Open Access Journals (Sweden)

    Radu Mihai Filep

    2016-07-01

    Full Text Available Aquaponic systems are integrated systems that combine fish farming and different types of plants. It involves a dynamic interaction between fish plants and bacteria. Fish and plants are dependent the equilibrium of dissolved nutrients and water quality. Only by striking a balance between dissolved nutrients and water quality we can achieve a large production of plants and healthy fish. Thus, control of water quality in an aquaponic system is essential in order to obtain performance in raising fish and plants. The experiment was conducted in the laboratory of Fisheries and Aquaculture of the Faculty of Animal Science of the University of Agronomic Sciences and Veterinary Medicine of Bucharest within a period of 30 days. The system used for the experiment was designed and developed in the laboratory mentioned above. The plant used for water treatment in the system was basil (Ocimum basilicum. Fish species grown in the system was culture carp (Cyprinus carpio. Indicators measured to assess water quality in the system were: temperature, pH, dissolved oxygen, total ammonia, nitrites, nitrates and phosphates. The values determined pH 7.4-7.6, dissolved oxygen 8-10 mg / l, NH4 0.05-05 mg/ l, NO2 0.1-3.2 mg / l, NO3 0-80 mg / l, 0.02-0.3 mg, PO4 0.02-0.3 mg/l were not too high. In conclusion it was demonstrated that water quality in the aquaponic system studied is propitious to the growth and welfare of fish the registered values are not to be harmful.

  9. Quality Control of Biotechnological Inputs DetectingMycoplasma

    Directory of Open Access Journals (Sweden)

    Cristiane Netto

    2015-04-01

    Full Text Available The aim of this work was to study the Polymerase Chain Reaction (PCR as a tool of quality control of bovine sera and cellular cultures used in the biotechnological industry. A total of 46 samples of bovine sera derived from two slaughterhouses and 33 samples of BHK21 cells derived from two biotechnological industries were evaluated using the primers GPO-3 (sense and MGSO (antisense. The PCR technique sensibility analysis showed that 280 bp were amplified for the quantities of 50 ng to 0.006 ng of Micoplasma DNA. The primers specificity was confirmed in the test using Staphylococcus aureus, Escherichia coli, Bacillus subtilisand Candida albicans; except by the positive control, none of the samples showed amplification. The presence of Mycoplasma in bovine sera and in the cultures of BHK21 cells showed that 56.5 and 15.2%, respectively, were contaminated. Thus, it was possible to conclude that PCR was a fast and confident technique to detect mycoplasma and that it could be used to control the quality of immunobiological products and inputs, such as sera and cultures of BHK21 cells.

  10. Methodology of quality control for brachytherapy {sup 125}I seeds

    Energy Technology Data Exchange (ETDEWEB)

    Moura, Eduardo S.; Zeituni, Carlos A.; Manzoli, Jose E.; Rostelato, Maria Elisa C.M. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)]. E-mail: esmoura@ipen.br

    2007-07-01

    This paper presents the methodology of quality control of {sup 125}I seeds used for brachytherapy. The {sup 125}I seeds are millimeter titanium capsules widely used in permanent implants of prostate cancer, allowing a high dose within the tumour and a low dose on the surrounding tissues, with very low harm to the other tissues. Besides, with this procedure, the patients have a low impotence rate and a small incidence of urinary incontinence. To meet the medical standards, an efficient quality control is necessary, showing values with the minimum uncertainness possible, concerning the seeds dimensions and their respective activities. The medical needles are used to insert the seeds inside the prostate. The needles used in brachytherapy have an internal diameter of 1.0 mm, so it is necessary {sup 125}I seeds with an external maximum diameter of 0.85 mm. For the seeds and the spacer positioning on the planning sheet, the seeds must have a length between 4.5 and 5.0 mm. The activities must not vary more than 5% in each batch of {sup 125}I seeds. For this methodology, we used two ionization chamber detectors and one caliper. In this paper, the methodology using one control batch with 75 seeds manufactured by GE Health care Ltd is presented. (author)

  11. Software application for quality control protocol of mammography systems

    International Nuclear Information System (INIS)

    Considering the fact that the Quality Control of the technological process of the mammographic system involves testing of a large number of parameters, it is clearly evident that there is a need for using the information technology for gathering, processing and storing of all the parameters that are result of this process. The main goal of this software application is facilitation and automation of the gathering, processing, storing and presenting process of the data related to the qualification of the physical and technical parameters during the quality control of the technological process of the mammographic system. The software application along with its user interface and database has been made with the Microsoft Access 2003 application which is part of the Microsoft Office 2003 software packet and has been chosen as a platform for developing because it is the most commonly used office application today among the computer users in the country. This is important because it will provide the end users a familiar environment to work in, without the need for additional training and improving the computer skills that they posses. Most importantly, the software application is easy to use, fast in calculating the parameters needed and it is an excellent way to store and display the results. There is a possibility for up scaling this software solution so it can be used by many different users at the same time over the Internet. It is highly recommended that this system is implemented as soon as possible in the quality control process of the mammographic systems due to its many advantages.(Author)

  12. Novel jumbo biopsy forceps for surveillance of inflammatory bowel disease: a comparative retrospective assessment.

    Science.gov (United States)

    Song, Kenneth; Toweill, Daniel; Rulyak, Stephen J; Lee, Scott D

    2011-01-01

    Background and Study Aims. Most available jumbo cup forceps require a 3.7 mm biopsy channel, necessitating the use of standard-sized colonoscope. A newer jumbo forceps (Radial Jaw 4 Jumbo Biopsy Forceps [RJ4]) fits within a 3.2 mm biopsy channel, allowing use with a pediatric colonoscope. To assure the RJ4 did not alter biopsy adequacy, we compared the size and quality of specimens to a historical jumbo cup forceps (Radial Jaw 3 Max Capacity Biopsy Forceps, [RJ3 MC]). Patients and Methods. A retrospective comparative study of biopsies taken with either forceps. Biopsies were compared for diameter, depth, crush artifact, and acceptability for diagnosis. Results. 333 specimens were taken with RJ4 and 335 specimens with the RJ3 MC. Mean sample diameter was 4.45 mm and 4.55 mm for the RJ4 and RJ3 MC (P = 0.41). Mean depth of biopsies with the RJ4 was greater (P < 0.01). Conclusions. Biopsies from the RJ4 are similar in size and quality to biopsies from the RJ3 MC. The RJ4 has the advantage of fitting in a smaller biopsy channel.

  13. Novel Jumbo Biopsy Forceps for Surveillance of Inflammatory Bowel Disease: A Comparative Retrospective Assessment

    Directory of Open Access Journals (Sweden)

    Kenneth Song

    2011-01-01

    Full Text Available Background and Study Aims. Most available jumbo cup forceps require a 3.7 mm biopsy channel, necessitating the use of standard-sized colonoscope. A newer jumbo forceps (Radial Jaw 4 Jumbo Biopsy Forceps [RJ4] fits within a 3.2 mm biopsy channel, allowing use with a pediatric colonoscope. To assure the RJ4 did not alter biopsy adequacy, we compared the size and quality of specimens to a historical jumbo cup forceps (Radial Jaw 3 Max Capacity Biopsy Forceps, [RJ3 MC]. Patients and Methods. A retrospective comparative study of biopsies taken with either forceps. Biopsies were compared for diameter, depth, crush artifact, and acceptability for diagnosis. Results. 333 specimens were taken with RJ4 and 335 specimens with the RJ3 MC. Mean sample diameter was 4.45 mm and 4.55 mm for the RJ4 and RJ3 MC (=0.41. Mean depth of biopsies with the RJ4 was greater (<0.01. Conclusions. Biopsies from the RJ4 are similar in size and quality to biopsies from the RJ3 MC. The RJ4 has the advantage of fitting in a smaller biopsy channel.

  14. Implementation of Quality Assurance and Quality Control Measures in the National Phenology Database

    Science.gov (United States)

    Gerst, K.; Rosemartin, A.; Denny, E. G.; Marsh, L.; Barnett, L.

    2015-12-01

    The USA National Phenology Network (USA-NPN; www.usanpn.org) serves science and society by promoting a broad understanding of plant and animal phenology and the relationships among phenological patterns and environmental change. The National Phenology Database has over 5.5 million observation records for plants and animals for the period 1954-2015. These data have been used in a number of science, conservation and resource management applications, including national assessments of historical and potential future trends in phenology, regional assessments of spatio-temporal variation in organismal activity, and local monitoring for invasive species detection. Customizable data downloads are freely available, and data are accompanied by FGDC-compliant metadata, data-use and data-attribution policies, and vetted documented methodologies and protocols. The USA-NPN has implemented a number of measures to ensure both quality assurance and quality control. Here we describe the resources that have been developed so that incoming data submitted by both citizen and professional scientists are reliable; these include training materials, such as a botanical primer and species profiles. We also describe a number of automated quality control processes applied to incoming data streams to optimize data output quality. Existing and planned quality control measures for output of raw and derived data include: (1) Validation of site locations, including latitude, longitude, and elevation; (2) Flagging of records that conflict for a given date for an individual plant; (3) Flagging where species occur outside known ranges; (4) Flagging of records when phenophases occur outside of the plausible order for a species; (5) Flagging of records when intensity measures do not follow a plausible progression for a phenophase; (6) Flagging of records when a phenophase occurs outside of the plausible season, and (7) Quantification of precision and uncertainty for estimation of phenological metrics

  15. Radiation Dosimetry for Quality Control of Food Preservation and Disinfestation

    DEFF Research Database (Denmark)

    McLaughlin, W.L.; Miller, Arne; Uribe, R.M.

    1983-01-01

    In the use of x and gamma rays and scanned electron beams to extend the shelf life of food by delay of sprouting and ripening, killing of microbes, and control of insect population, quality assurance is provided by standardized radiation dosimetry. By strategic placement of calibrated dosimeters...... speed) to meet changes that occur in product and source parameters (e.g. bulk density and radiation spectrum). Routine dosimetry methods and certain corrections of dosimetry data may be selected for the radiations used in typical food processes....

  16. Quality assurance in a cask fleet parts control system

    International Nuclear Information System (INIS)

    This paper discusses applicable portions of the eighteen Quality Assurance criteria of Subpart H, 10 CFR 71 which are incorporated into a relational data base system which has been designed to manage the spare parts control system for a fleet of spent nuclear fuel casks. The system includes not only parts in warehouse storage but parts in use in the field plus casks, ancillary equipment, test equipment, support devices, and even personnel. It provides a high degree of assurance that any device for which a condition for certification has expired will be flagged for recertification testing or removal from service well before the critical date

  17. Radiation Dosimetry for Quality Control of Food Preservation and Disinfestation

    DEFF Research Database (Denmark)

    McLaughlin, W.L.; Miller, Arne; Uribe, R.M.

    1983-01-01

    In the use of x and gamma rays and scanned electron beams to extend the shelf life of food by delay of sprouting and ripening, killing of microbes, and control of insect population, quality assurance is provided by standardized radiation dosimetry. By strategic placement of calibrated dosimeters...... parameters (e.g. conveyor speed) to meet changes that occur in product and source parameters (e.g. bulk density and radiation spectrum). Routine dosimetry methods and certain corrections of dosimetry data may be selected for the radiations used in typical food processes....

  18. DES exposure checker: Dark Energy Survey image quality control crowdsourcer

    Science.gov (United States)

    Melchior, Peter; Sheldon, Erin; Drlica-Wagner, Alex; Rykoff, Eli S.

    2015-11-01

    DES exposure checker renders science-grade images directly to a web browser and allows users to mark problematic features from a set of predefined classes, thus allowing image quality control for the Dark Energy Survey to be crowdsourced through its web application. Users can also generate custom labels to help identify previously unknown problem classes; generated reports are fed back to hardware and software experts to help mitigate and eliminate recognized issues. These problem reports allow rapid correction of artifacts that otherwise may be too subtle or infrequent to be recognized.

  19. Experimental study and quality control of a technetium-99 generator

    International Nuclear Information System (INIS)

    The performarce of a generator of technetium-99m to be used in nuclear medicine is studied. The most interesting characteristic of this generator is the use of a U-shaped chromatographuc column so as to improve its efficiency and design without increasing the weight of its shield. With the aim of improving certain aspects of the generator, molibdenum-99 was applied to adecuate pH, pirogens were removed from the column set up before application, application was effected on a dry column, the smallest alumina particles were separated on the column, etc. The most important parameters of an isotopic generator are studied, and the corresponding quality controls performed. (author)

  20. Automated quality control for genome wide association studies.

    Science.gov (United States)

    Ellingson, Sally R; Fardo, David W

    2016-01-01

    This paper provides details on the necessary steps to assess and control data in genome wide association studies (GWAS) using genotype information on a large number of genetic markers for large number of individuals. Due to varied study designs and genotyping platforms between multiple sites/projects as well as potential genotyping errors, it is important to ensure high quality data. Scripts and directions are provided to facilitate others in this process. PMID:27635224

  1. QUALITY CONTROL PARAMETERS OF BRIHAT DASHAMULA TAILA: A PRELIMINARY STUDY

    Directory of Open Access Journals (Sweden)

    Sharma Vinay

    2011-05-01

    Full Text Available Standard analytical parameters of a number of Ayurvedic oils have been described in API. Brihat Dashamula Taila is one of the most commonly used oil by Ayurvedic Physicians. But there no standard analytical parameters are available in any authentic texts. Therefore this study aimed to set the quality control parameters with SOP of Brihat Dashamula Taila and found values like Refractive index (1.47 at 400C, specific gravity (0.923 at 250C Acid value (1.2, Iodine value (92.6 and Saponification value (86.34 may be considered as standard.

  2. Some contributions aiming to the evolution of radiodiagnosis quality control

    International Nuclear Information System (INIS)

    The importance of the implantation of quality control programs in radiodiagnostics, is shown. An experimental study to evalute the X-ray beam spectral behaviour was carried out, considering: techniques, patients, detection apparatus and filtering. The film sensitivity for oral radiology and conventional radiology was evaluated. The behaviour of chemical substances used in Brazil for image processing is analysed. A device for KVp test developed at the University of Wisconsin, was compared with two kilovoltage measuring techniques. Details of development and construction of a practical device, in two versions, for determining peak kilovoltage of in X-ray tubes, which are being used in some radiological services, are presented. (M.C.K.)

  3. Additive Manufacturing: Multi Material Processing and Part Quality Control

    OpenAIRE

    Pedersen, David Bue; De Chiffre, Leonardo; Hansen, Hans Nørgaard

    2013-01-01

    Denne Ph.D afhandling,?Additive Manufacturing: Multi Material Processing and Part Quality Control?, omhandler additive fremstillingsmetoder, hvilket er en familie af processer der er kendetegnet ved at de er computerstyret, de drager nytte af en høj grad af automation, og de fremstiller emner lagvis ved addition af materiale. To områder af særlig interesse er addreseret i denne afhandling. De er begge forankret i to meget forskellige områder, men tjener fælles formål. At styrke additive frems...

  4. Fine needle biopsy of abdominal organs in dogs -- indications, contraindications and performance technique.

    Science.gov (United States)

    Glińska-Suchocka, K; Jankowski, M; Kubiak, K; Spuzak, J; Dzimira, S; Nicpoń, J

    2013-01-01

    Recent years have seen in both human and veterinary medicine the development of numerous techniques allowing for evaluation and classification of changes in individual organs and tissues. Despite introduction of such techniques into diagnostics as among others, CT, MRI, CEUS or elastography, biopsy is still considered a "golden standard" and it is a procedure performed in order to obtain a final diagnosis. There are many biopsy techniques, such as fine needle aspiration biopsy, core biopsy as well as methods of performing a procedure, e.g. blind biopsy, biopsy under USG control and biopsy during laparotomy. In the article usefulness of biopsy techniques in relation to diagnostics of individual abdominal organ, as well as the procedure technique, contraindication and complications are discussed. PMID:24597324

  5. Validation of gamma irradiator controls for quality and regulatory compliance

    International Nuclear Information System (INIS)

    Since 1978 the U.S. Food and Drug Administration (FDA) has had both the legal authority and the Current Good Manufacturing Practice (CGMP) regulations in place to require irradiator owners who process medical devices to produce evidence of Irradiation Process Validation. One of the key components of Irradiation Process Validation is the validation of the irradiator controls. However, it is only recently that FDA audits have focused on this component of the process validation. What is Irradiator Control System Validation? What constitutes evidence of control? How do owners obtain evidence? What is the irradiator supplier's role in validation? How does the ISO 9000 Quality Standard relate to the FDA's CGMP requirement for evidence of Control System Validation? This paper presents answers to these questions based on the recent experiences of Nordion's engineering and product management staff who have worked with several US-based irradiator owners. This topic - Validation of Irradiator Controls - is a significant regulatory compliance and operations issues within the irradiator suppliers' and users' community. (author)

  6. Endoscopic duodenal biopsy in children

    Directory of Open Access Journals (Sweden)

    El Mouzan Mohammad

    2006-01-01

    Full Text Available Background: Biopsy of the small bowel is frequently obtained by endoscopic forceps instead of the classical suction capsule, yet reports from developing countries are scarce. Aim of the study: to report our experience on the diagnostic value of this procedure in our community. Patients and methods: A retrospective analysis of all endoscopic duodenal biopsies (EDB, performed on all patients below 18 years of age. Data retrieved from the records included age, gender, nationality, indication for biopsy, the endoscopic findings, and the results of histopathology. Results: From 1993 to 2002, 241 endoscopic biopsies were performed on 241 consecutive children. Most of the children (96% were Saudi nationals, the age range between six weeks to 18 years, and male to female ratio was 0.7: 1. All of the biopsy material was adequate for routine histopathology. The commonest indications for biopsy were short stature and chronic diarrhea in 116/241 (48% and 102/241 (43% of the children respectively. Refractory rickets accounted for 11/241 (5% of the indications. The prevalence of villous atrophy was highest in children presenting with chronic diarrhea (40%, compared to short stature (22%. Other less common, but important findings were villous atrophy in three unusual conditions (one refractory rickets, one unexplained anemia, and one polyendocrinopathy, two cases of intestinal Giardia lamblia infestation, three cases of intestinal lymphangiectasis and one case of Mycobacterium avium intracellulare. Unexpected endoscopic findings were documented in 34/241 (14% of the children. Conclusions: Endoscopic duodenal biopsy is adequate not only for the diagnosis of villous atrophy, but also for the detection of other gastroenteropathies. Accordingly, when expertise and equipments are available, EDB should be the procedure of choice not only in industrialized but also in developing countries.

  7. Needle biopsy of the breast.

    Science.gov (United States)

    Millis, R R

    1984-01-01

    Recently, there has been a considerable increase in the use of both fine-needle aspiration biopsy (aspiration cytology) and tissue-core needle biopsy of the breast. In patients with suspected breast cancer, needle biopsy is frequently used to confirm the diagnosis before treatment is planned. This allows a more thoughtful approach to the patient and full screening for possible metastatic disease prior to definitive surgery. Needle biopsy techniques are simple, rapid, can be performed in the doctor's office, and save time, equipment, and hospital beds. Complications are few. Aspiration cytology has the advantage that it is quick to perform, the preparation can be examined almost immediately and, in the event of an unsatisfactory smear, the procedure can be repeated. However, the diagnosis is based on purely cytological evaluation, and the information obtained is somewhat limited. Reported accuracy rates range from 42 to 96%. False positive reports are rare but have occurred in most centers, and a high degree of accuracy will only be obtained by experienced practitioners. Tissue-core needle biopsy has the advantage that the diagnosis is based on histopathological assessment, but the procedure is slightly more time consuming, is more traumatic for the patient, and the equipment is more expensive. Accuracy rates range from 67 to 98.5%. During the past 4 years, 329 tissue-core (Tru-Cut) biopsies have been performed in the Guy's Hospital Breast Unit, with an accuracy rate of 83% in the diagnosis of carcinoma. The procedure has been acceptable to most patients, and complications have been minimal. Studies comparing the use of aspiration cytology and tissue-core needle biopsy in the diagnosis of mammary carcinoma have produced variable results. Both methods have advantages and disadvantages, and the choice of technique must depend on the clinical situation and the preferences and skills of the practitioners involved in the management of the patient. PMID:6377049

  8. US quality control in Italy: present and future

    Science.gov (United States)

    Balbis, S.; Musacchio, C.; Guiot, C.; Spagnolo, R.

    2011-02-01

    US diagnostic equipments are widely diffused in Italy but, in spite of recommendations (e.g. ISPESL-Ministry of Health (1999) and SIRM (Società Italiana di Radiologia Medica, 2004), US quality controls are restricted to only a few public sanitary structure and a national (or even regional) quality assurance program for testing the performances of the US equipments is still missing. A joint Research Centre among the three Piedmontese Universities and INRIM, partially funded by Regione Piemonte, has been established in 2009 as Reference Centre for Medical Ultrasounds (CRUM). In addition to research, development and training tasks, the Centre aims at the local diffusion of the quality assurance in clinical US equipments. According to data from the Ministry of Health (2006), around 7 % of the Italian US diagnostic equipments (946 over 13526) are located in Piedmont: mostly (75.6%) in public hospitals, 9.3 % in conventionated hospitals, 4.3% in public and 10.8% in private territorial structures. The goal is the provision of a regional database, which progressively includes data related to acceptance test, status and QC tests and maintenance, in order to drive equipment turnover and carefully monitoring the overall equipment efficiency. Moreover, facilities are available at CRUM for monitoring both beam geometry and acoustic power and performing quantitative assessment of the delivered energy intensity.

  9. Terrestrial Method for Airborne Lidar Quality Control and Assessment

    Science.gov (United States)

    Alsubaie, N. M.; Badawy, H. M.; Elhabiby, M. M.; El-Sheimy, N.

    2014-11-01

    Most of LiDAR systems do not provide the end user with the calibration and acquisition procedures that can use to validate the quality of the data acquired by the airborne system. Therefore, this system needs data Quality Control (QC) and assessment procedures to verify the accuracy of the laser footprints and mainly at building edges. This research paper introduces an efficient method for validating the quality of the airborne LiDAR point clouds data using terrestrial laser scanning data integrated with edge detection techniques. This method will be based on detecting the edge of buildings from these two independent systems. Hence, the building edges are extracted from the airborne data using an algorithm that is based on the standard deviation of neighbour point's height from certain threshold with respect to centre points using radius threshold. The algorithm is adaptive to different point densities. The approach is combined with another innovative edge detection technique from terrestrial laser scanning point clouds that is based on the height and point density constraints. Finally, statistical analysis and assessment will be applied to compare these two systems in term of edge detection extraction precision, which will be a priori step for 3D city modelling generated from heterogeneous LiDAR systems

  10. THE IMPACT OF CONTROLS ON FINANCIAL REPORTING QUALITY

    Directory of Open Access Journals (Sweden)

    Cecilia (DAMOC NICA

    2015-11-01

    Full Text Available The study identifies the impact of the internal and external control of the quality of financial reporting, considering the professional accountants’ opinions, evaluating the extent to which financial and non-financial information presented annually by companies represent a guarantee of compliance with the ethical principles of professionals, and also a transparency presentation of the economic activity, risk management, at the same time protecting the interests of stakeholders in the company. The quantitative analysis performed is based on a questionnaire applied to the professional accountants being conducted on a sample of companies in Romania, in various sectors and presents a comparative study of the importance of each type of internal and external control in the delivery of financial reports and non- annual companies, real and credible.

  11. Physical aspects of radiotherapy quality assurance: quality control protocol - Update of IAEA TECDOC-1151

    International Nuclear Information System (INIS)

    An International Atomic Energy Agency (IAEA) regional project for Latin America (ARCAL XXX) entitled ''Improvement of Quality Assurance in Radiotherapy'' was completed in 2000. One of its more relevant contributions was the development of a quality control protocol for radiotherapy physics, published as an IAEA TECDOC. This was the first document of this type published entirely in Spanish, having a marked practical approach, and focused on the situation of the radiotherapy in Latin America at that time. The document found broad application and was widely adopted in the region. The recommendations and guidelines of the document were also applied in other countries having a similar level of development in radiotherapy. Since the publication of TECDOC-1151, the status of radiotherapy has changed significantly in many of the radiotherapy institutions in the Latin American region. Technological advances and improvements have created the need for a thorough revision of the protocol to reflect the current situation regarding radiotherapy equipment and techniques, keeping it a suitable and practical tool to guarantee high quality in the nowadays rather complex radiotherapy treatments. To fulfill this goal, a specific task was included in the IAEA regional project ''Improvements in Quality Assurance in Radiotherapy in the Latin American Region'' (ARCAL XC), running during the period 2007-2009, where a group of experts was formed and commissioned with the document revision. The general criteria and procedures given in TECDOC-1151 are still valid for basic radiotherapy equipment, widely disseminated and playing an important role in clinical practice in the region. It was then considered to develop additional criteria and recommendations for the new advanced technologies in the form of a supplement to the existing protocol. The supplement describes procedures and provides recommendations for newly introduced radiotherapy equipment, followed by a series of appendixes where

  12. 40 CFR 81.54 - Cook Inlet Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Cook Inlet Intrastate Air Quality...) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.54 Cook Inlet Intrastate Air Quality Control Region. The Cook...

  13. 40 CFR 81.32 - Puget Sound Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Puget Sound Intrastate Air Quality...) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.32 Puget Sound Intrastate Air Quality Control Region. The Puget...

  14. 40 CFR 81.51 - Portland Interstate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Portland Interstate Air Quality...) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.51 Portland Interstate Air Quality Control Region. The Portland...

  15. 40 CFR 81.35 - Louisville Interstate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Louisville Interstate Air Quality...) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.35 Louisville Interstate Air Quality Control Region. The...

  16. 40 CFR 81.29 - Metropolitan Indianapolis Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Air Quality Control Region. 81.29 Section 81.29 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.29 Metropolitan Indianapolis Intrastate Air Quality...

  17. 40 CFR 81.17 - Metropolitan Los Angeles Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Metropolitan Los Angeles Air Quality...) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.17 Metropolitan Los Angeles Air Quality Control Region. The Metropolitan...

  18. 40 CFR 81.52 - Wasatch Front Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Wasatch Front Intrastate Air Quality...) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.52 Wasatch Front Intrastate Air Quality Control Region. The Wasatch...

  19. 40 CFR 81.42 - Chattanooga Interstate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Chattanooga Interstate Air Quality...) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.42 Chattanooga Interstate Air Quality Control Region. The...

  20. 40 CFR 81.36 - Maricopa Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Maricopa Intrastate Air Quality...) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.36 Maricopa Intrastate Air Quality Control Region. The...

  1. 40 CFR 81.67 - Lake Michigan Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Lake Michigan Intrastate Air Quality...) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.67 Lake Michigan Intrastate Air Quality Control Region. The...

  2. FORMULATION AND QUALITY CONTROL OF METERED DOSE INHALER: A REVIEW

    Directory of Open Access Journals (Sweden)

    Ramteke K.H.

    2012-04-01

    Full Text Available The MDI is now established as the principal dosage form of inhalation drug therapy for bronchial asthma and chronic obstructive pulmonary disease (COPD. Metered dose inhalers (MDIs are pharmaceutical delivery systems designed for oral or nasal use, which deliver discrete doses of aerosolized medicament to the respiratory tract. The MDI contains the active substance, dissolved or suspended in a liquefied propellant system held in a pressurized container that is sealed with a metering valve. In general, MDI formulations can take the form of either suspensions or solutions. Traditionally the preferred route has been to formulate a suspension of the micronized drug substance in the liquid propellant (CFC or HFA. In some cases, additional excipients (e.g., surfactants and/or co- solvents have been added to improve the quality of the dispersion. Quality control testing of MDI batches is applied to the individual inhaler components prior to manufacture, as in-process controls during the manufacturing, and to the finished product. An exhaustive search for new propellants was made at the time of the switch away from CFCs, and it is unlikely that new ones will be found with the necessary physicochemical properties combined with an excellent safety profile.

  3. Quality control methods for KOOS operational sea surface temperature products

    Institute of Scientific and Technical Information of China (English)

    YANG Chansu; KIM Sunhwa

    2016-01-01

    Sea surface temperature SST obtained from the initial version of the Korea Operational Oceanographic System (KOOS) SST satellite have low accuracy during summer and daytime. This is attributed to the diurnal warming effect. Error estimation of SST data must be carried out to use the real-time forecasting numerical model of the KOOS. This study suggests two quality control methods for the KOOS SST system. To minimize the diurnal warming effect, SSTs of areas where wind speed is higher than 5 m/s were used. Depending on the wind threshold value, KOOS SST data for August 2014 were reduced by 0.15°C. Errors in SST data are considered to be a combination of random, sampling, and bias errors. To estimate bias error, the standard deviation of bias between KOOS SSTs and climatology SSTs were used. KOOS SST data yielded an analysis error standard deviation value similar to OSTIA and NOAA NCDC (OISST) data. The KOOS SST shows lower random and sampling errors with increasing number of observations using six satellite datasets. In further studies, the proposed quality control methods for the KOOS SST system will be applied through more long-term case studies and comparisons with other SST systems.

  4. mRNA quality control pathways in Saccharomyces cerevisiae

    Indian Academy of Sciences (India)

    Satarupa Das; Biswadip Das

    2013-09-01

    Efficient production of translation-competent mRNAs involves processing and modification events both in the nucleus and cytoplasm which require a number of complex machineries at both co-transcriptional and post-transcriptional levels. Mutations in the genomic sequence sometimes result in the formation of mutant non-functional defective messages. In addition, the enormous amounts of complexities involved in the biogenesis of mRNPs in the nucleus very often leads to the formation of aberrant and faulty messages along with their functional counterpart. Subsequent translation of these mutant and defective populations of messenger RNAs could possibly result in the unfaithful transmission of genetic information and thus is considered a threat to the survival of the cell. To prevent this possibility, mRNA quality control systems have evolved both in the nucleus and cytoplasm in eukaryotes to scrutinize various stages of mRNP biogenesis and translation. In this review, we will focus on the physiological role of some of these mRNA quality control systems in the simplest model eukaryote Saccharomyces cerevisiae.

  5. AMAZON RAINFOREST COSMETICS: CHEMICAL APPROACH FOR QUALITY CONTROL

    Directory of Open Access Journals (Sweden)

    Mariko Funasaki

    2016-02-01

    Full Text Available The market for natural cosmetics featuring ingredients derived from Amazon natural resources is growing worldwide. However, there is neither enough scientific basis nor quality control of these ingredients. This paper is an account of the chemical constituents and their biological activities of fourteen Amazonian species used in cosmetic industry, including açaí (Euterpe oleracea, andiroba (Carapa guianensis, bacuri (Platonia insignis, Brazil nut (Bertholletia excelsa, buriti (Mauritia vinifera or M. flexuosa, cumaru (Dipteryx odorata, cupuaçu (Theobroma grandiflorum, guarana (Paullinia cupana, mulateiro (Calycophyllum spruceanum, murumuru (Astrocaryum murumuru, patawa (Oenocarpus bataua or Jessenia bataua, pracaxi (Pentaclethra macroloba, rosewood (Aniba rosaeodora, and ucuuba (Virola sebifera. Based on the reviewed articles, we selected chemical markers for the quality control purpose and evaluated analytical methods. Even though chromatographic and spectroscopic methods are major analytical techniques in the studies of these species, molecular approaches will also be important as used in food and medicine traceability. Only a little phytochemical study is available about most of the Amazonian species and some species such as açaí and andiroba have many reports on chemical constituents, but studies on biological activities of isolated compounds and sampling with geographical variation are limited.

  6. Cumulative sum quality control for calibrated breast density measurements

    Energy Technology Data Exchange (ETDEWEB)

    Heine, John J.; Cao Ke; Beam, Craig [Cancer Prevention and Control Division, Moffitt Cancer Center, 12902 Magnolia Drive, Tampa, Florida 33612 (United States); Division of Epidemiology and Biostatistics, School of Public Health, University of Illinois at Chicago, 1603 W. Taylor St., Chicago, Illinois 60612 (United States)

    2009-12-15

    Purpose: Breast density is a significant breast cancer risk factor. Although various methods are used to estimate breast density, there is no standard measurement for this important factor. The authors are developing a breast density standardization method for use in full field digital mammography (FFDM). The approach calibrates for interpatient acquisition technique differences. The calibration produces a normalized breast density pixel value scale. The method relies on first generating a baseline (BL) calibration dataset, which required extensive phantom imaging. Standardizing prospective mammograms with calibration data generated in the past could introduce unanticipated error in the standardized output if the calibration dataset is no longer valid. Methods: Sample points from the BL calibration dataset were imaged approximately biweekly over an extended timeframe. These serial samples were used to evaluate the BL dataset reproducibility and quantify the serial calibration accuracy. The cumulative sum (Cusum) quality control method was used to evaluate the serial sampling. Results: There is considerable drift in the serial sample points from the BL calibration dataset that is x-ray beam dependent. Systematic deviation from the BL dataset caused significant calibration errors. This system drift was not captured with routine system quality control measures. Cusum analysis indicated that the drift is a sign of system wear and eventual x-ray tube failure. Conclusions: The BL calibration dataset must be monitored and periodically updated, when necessary, to account for sustained system variations to maintain the calibration accuracy.

  7. Heme oxygenase-1 regulates mitochondrial quality control in the heart

    Science.gov (United States)

    Hull, Travis D.; Boddu, Ravindra; Guo, Lingling; Tisher, Cornelia C.; Traylor, Amie M.; Patel, Bindiya; Joseph, Reny; Prabhu, Sumanth D.; Suliman, Hagir B.; Piantadosi, Claude A.; Agarwal, Anupam; George, James F.

    2016-01-01

    The cardioprotective inducible enzyme heme oxygenase-1 (HO-1) degrades prooxidant heme into equimolar quantities of carbon monoxide, biliverdin, and iron. We hypothesized that HO-1 mediates cardiac protection, at least in part, by regulating mitochondrial quality control. We treated WT and HO-1 transgenic mice with the known mitochondrial toxin, doxorubicin (DOX). Relative to WT mice, mice globally overexpressing human HO-1 were protected from DOX-induced dilated cardiomyopathy, cardiac cytoarchitectural derangement, and infiltration of CD11b+ mononuclear phagocytes. Cardiac-specific overexpression of HO-1 ameliorated DOX-mediated dilation of the sarcoplasmic reticulum as well as mitochondrial disorganization in the form of mitochondrial fragmentation and increased numbers of damaged mitochondria in autophagic vacuoles. HO-1 overexpression promotes mitochondrial biogenesis by upregulating protein expression of NRF1, PGC1α, and TFAM, which was inhibited in WT animals treated with DOX. Concomitantly, HO-1 overexpression inhibited the upregulation of the mitochondrial fission mediator Fis1 and resulted in increased expression of the fusion mediators, Mfn1 and Mfn2. It also prevented dynamic changes in the levels of key mediators of the mitophagy pathway, PINK1 and parkin. Therefore, these findings suggest that HO-1 has a novel role in protecting the heart from oxidative injury by regulating mitochondrial quality control. PMID:27110594

  8. Implementation of a quality control program in nuclear medicine

    International Nuclear Information System (INIS)

    Rectilinear scanners and dose calibrators were tested for a variety of operating conditions and performance.The tests for rectilinear scanners were based on image quality obtained with phantoms of the brain, liver and thyroid. The parameters investigated for rectilinear scanners included the direct control of the operator, such as the proper setting of the focal distance, the velocity, the photopeak calibration, contrast, correct collimator, line spacing and back ground count.The accuracy of dose calibrators was checked with sources of Cs-137, Co-57 and Co-60. The linearity of dose calibrators was checked with sources of technetium-99m and geometry was likewise checked with variable volumes of technetium-99m.The evaluation of the proper setting for rectilinear scanners was made by determining the number of hot and cold areas in the phantom before and after corrective adjustments of physical parameters.The results obtained on rectilinear scanners indicated efficiencies in the operating conditions. The results found on dose calibrators shown that geometry effect was minimal; the reproducibility and stability was satisfactory. However,more than a half(60%)of the dose calibrators tested for accuracy and linearity were performed without acceptable limits. We can conclude that is very useful and important the implementation of quality control programme to entire diagnostic process in nuclear medicine. (author)

  9. IAEA quality control atlas for scintillation camera systems

    International Nuclear Information System (INIS)

    Nuclear medicine professionals deal with various medical images almost daily. Often, however, they may not be aware -- as a result of the limited information available to them or of a lack of experience -- of possible image problems, among them abnormalities in the image and various artefacts. At times, even when it is eventually seen that an image is incorrect, it is already too late to take any remedial action, for example in the case of images with crystal hydration at various stages. To provide nuclear medicine professionals with an assortment of examples of possible image errors and problems, this Quality Control Atlas has been produced under the auspices of the IAEA, through technical co-operation projects and research and technical contracts. About 250 typical nuclear scintillation camera images -- normal images as well as those showing abnormalities and various artefacts -- have been collected in this volume, all catalogued and provided with explanations as to the causes of and solutions to each individual image problem. This atlas is intended to be used as a guide on how to take proper quality control measures, on performing situation and problem analysis, and on problem prevention. It is hoped that the atlas will be especially useful to physicists, physicians, technologists and service engineers in the nuclear medicine field. It is available in CD-ROM, Internet and hard copy versions

  10. UPLC®-RAD the new standard in quality control of PET radiopharmaceutical

    NARCIS (Netherlands)

    Maas, B.; Zijlma, R.; Bannink, A.; Lub-De Hooge, M.; Elsinga, P.H.; Dierckx, R.A.J.O.; Boersma, H.H.; Luurtsema, G.

    2013-01-01

    Objectives: Good Manufacturing Practice (GMP) compliant productions require validated, quality control procedures of the radiopharmaceutical. Quality control of the final product is conventionally performed by High Performance Liquid Chromatography (HPLC) with UV and radioactivity (RAD) detection. T

  11. DTIPrep: Quality Control of Diffusion-Weighted Images

    Directory of Open Access Journals (Sweden)

    Ipek eOguz

    2014-01-01

    Full Text Available In the last decade, diffusion MRI (dMRI studies of the human and animal brain have been used to investigate a multitude of pathologies and drug-related effects in neuroscience research. Study after study identifies white matter (WM degeneration as a crucial biomarker for all these diseases. The tool of choice for studying WM is dMRI. However, dMRI has inherently low signal-to-noise ratio and its acquisition requires a relatively long scan time; in fact, the high loads required occasionally stress scanner hardware past the point of physical failure. As a result, many types of artifacts implicate the quality of diffusion imagery. Using these complex scans containing artifacts without quality control (QC can result in considerable error and bias in the subsequent analysis, negatively affecting the results of research studies using them. However, dMRI QC remains an under-recognized issue in the dMRI community as there are no user-friendly tools commonly available to comprehensively address the issue of dMRI QC. As a result, current dMRI studies often perform a poor job at dMRI QC.Thorough QC of diffusion MRI will reduce measurement noise and improve reproducibility, and sensitivity in neuroimaging studies; this will allow researchers to more fully exploit the power of the dMRI technique and will ultimately advance neuroscience. Therefore, in this manuscript, we present our open-source software, DTIPrep, as a unified, user friendly platform for thorough quality control of dMRI data. These include artifacts caused by eddy-currents, head motion, bed vibration and pulsation, venetian blind artifacts, as well as slice-wise and gradient-wise intensity inconsistencies. This paper summarizes a basic set of features of DTIPrep described earlier and focuses on newly added capabilities related to directional artifacts and bias analysis.

  12. Organ donation quality control in Abruzzo region (Italy).

    Science.gov (United States)

    Parzanese, I; Maccarone, D; Caniglia, L; Pisani, F; Laurenzi, C; Famulari, A

    2006-05-01

    Abruzzo is a region in central Italy with a population of 1,262,392. Within this region there are 13 hospitals with intensive care units, four of which have neurosurgical units. The Regional Centre for Transplants in L'Aquila is notified of encephalic deaths in hospitals in Abruzzo and Molise and coordinates organ retrieval and transplantation. Organ donation is a process that involves a whole series of professionals who, operating in a sequential manner in each hospital, make possible the use of a cadaveric organ to give life to a person or improve the quality of life of a patient on a waiting list. Quality control procedures were introduced in 2001 and involve all of the hospitals in the region with intensive care units. The system for quality control was computerized in 2004 and is used in the four hospitals with neurosurgical units (type A hospitals) and in the 13 hospitals without (type B hospitals); the different types of deaths (cause of death, age, etc) are also analyzed with this system. One of the aims of this system is to discover the theoretical donation capacity, taking as benchmark values those resulting from the regional average and those published in international literature, and noting any shortcomings. It has emerged that donor identification is well organized and efficient and this is thanks to a concerted effort that has been made to overcome technical and organizational problems connected to donor detection and donor maintenance during the 6 hours of legal observation. The high percentage of opposition to organ removal, despite the fall registered in the first half of this year (2005), is still above the national average and still remains a critical point in the organ donation process.

  13. Introducing Quality Control in the Chemistry Teaching Laboratory Using Control Charts

    Science.gov (United States)

    Schazmann, Benjamin; Regan, Fiona; Ross, Mary; Diamond, Dermot; Paull, Brett

    2009-01-01

    Quality control (QC) measures are less prevalent in teaching laboratories than commercial settings possibly owing to a lack of commercial incentives or teaching resources. This article focuses on the use of QC assessment in the analytical techniques of high performance liquid chromatography (HPLC) and ultraviolet-visible spectroscopy (UV-vis) at…

  14. Protocol biopsies for renal transplantation

    Directory of Open Access Journals (Sweden)

    Rush David

    2010-01-01

    Full Text Available Protocol biopsies in renal transplantation are those that are procured at predetermined times post renal transplantation, regardless of renal function. These biopsies have been useful to study the natural history of the transplanted kidney as they have detected unexpected - i.e. "subclinical" pathology. The most significant subclinical pathologies that have been detected with protocol biopsies have been acute lesions, such as cellular and antibody mediated rejection, and chronic lesions, such as interstitial fibrosis and tubular atrophy, and transplant glomerulopathy. The potential benefit of early recognition of the above lesions is that their early treatment may result in improved long-term outcomes. Conversely, the identification of normal histology on a protocol biopsy, may inform us about the safety of reduction in overall immunosuppression. Our centre, as well as others, is attempting to develop non-invasive methods of immune monitoring of renal transplant patients. However, we believe that until such methods have been developed and validated, the protocol biopsy will remain an indispensable tool for the complete care of renal transplant patients.

  15. The protein quality control system manages plant defence compound synthesis.

    Science.gov (United States)

    Pollier, Jacob; Moses, Tessa; González-Guzmán, Miguel; De Geyter, Nathan; Lippens, Saskia; Vanden Bossche, Robin; Marhavý, Peter; Kremer, Anna; Morreel, Kris; Guérin, Christopher J; Tava, Aldo; Oleszek, Wieslaw; Thevelein, Johan M; Campos, Narciso; Goormachtig, Sofie; Goossens, Alain

    2013-12-01

    Jasmonates are ubiquitous oxylipin-derived phytohormones that are essential in the regulation of many development, growth and defence processes. Across the plant kingdom, jasmonates act as elicitors of the production of bioactive secondary metabolites that serve in defence against attackers. Knowledge of the conserved jasmonate perception and early signalling machineries is increasing, but the downstream mechanisms that regulate defence metabolism remain largely unknown. Here we show that, in the legume Medicago truncatula, jasmonate recruits the endoplasmic-reticulum-associated degradation (ERAD) quality control system to manage the production of triterpene saponins, widespread bioactive compounds that share a biogenic origin with sterols. An ERAD-type RING membrane-anchor E3 ubiquitin ligase is co-expressed with saponin synthesis enzymes to control the activity of 3-hydroxy-3-methylglutaryl-CoA reductase (HMGR), the rate-limiting enzyme in the supply of the ubiquitous terpene precursor isopentenyl diphosphate. Thus, unrestrained bioactive saponin accumulation is prevented and plant development and integrity secured. This control apparatus is equivalent to the ERAD system that regulates sterol synthesis in yeasts and mammals but that uses distinct E3 ubiquitin ligases, of the HMGR degradation 1 (HRD1) type, to direct destruction of HMGR. Hence, the general principles for the management of sterol and triterpene saponin biosynthesis are conserved across eukaryotes but can be controlled by divergent regulatory cues. PMID:24213631

  16. Near Fatal Asthma: Clinical and Airway Biopsy Characteristics

    OpenAIRE

    Barbers, Richard G.; Papanikolaou, Ilias C.; Michael N. Koss; Ashish Patel ,; Elton Katagihara; Maggie Arenas; Khalid Chan; Azen, Colleen G.; Sharma, Om P.

    2012-01-01

    Background. Inflammation and remodeling are integral parts of asthma pathophysiology. We sought to describe the clinical and pathologic features of near fatal asthma exacerbation (NFE). Methods. Bronchial biopsies were collected prospectively from NFE I subjects. Another NFE II group and a moderate severity exacerbation control group (ME II) were retrospectively identified—no biopsies obtained. Results. All NFE II ( = 9 ) subjects exhibited remodeling and significant inflammation (eosinophi...

  17. Mammotome HH biopsy - the future of minimal invasive breast surgery?

    International Nuclear Information System (INIS)

    Vacuum-assisted breast biopsy / Mammotome HH '' R '' Breast Biopsy System/ is the milestone in the diagnosis of breast lesions. This system has proven to be as diagnostically reliable as open surgery, but without scarring, deformations and hospitalizations associated with an open procedure. The aim of our study was to assess the role and possibilities of using this biopsy in treatment of benign breast lesions like fibroadenoma. From 2001 to 2004, about 1118 Mammotome biopsies were performed in our Department. Among 445 Mammotome biopsies performed under US control there were 211 cases of fibroadenomas. Follow-up was performed in 156 patients with this result at 6 and 12 months after biopsy. In our study we took into considerations the size, localizations as well as performers. In 2002 there were 70.8% patients with total lesion excision, 16.7% with residual lesion and 12.5% women with hematomas or scars. In 2003-2004 there were more women with total lesion excision (84.3%), fewer residual tumors and other lesions. In future, Mammotome breast biopsy can replace scalpel, and will become an alternative method to open surgical excision of fibroadenomas. It is important especially in the cases of young women to prevent cosmetic deformations and scars. (author)

  18. SATURATION BIOPSY OF THE PROSTATE (REVIEW

    Directory of Open Access Journals (Sweden)

    A. V. Sadchenko

    2014-07-01

    Full Text Available Prostate biopsy is the principal method of diagnois of prostate cancer, allowing to start the adequate treatment. The tactics of the patients, which have negative initial biopsy, is a subject of discussion. Saturation biopsy is a “gold standard„ of diagnostics of PCA with repeat biopsy. Saturation biopsy of the prostate is not a primary procedure, usually apply in patients with negative biopsies in anamnesis, patients with multifocal PIN and ASAP. Saturation biopsy allows to more precisely predict the volume and degree of malignancy of PCA, that can be used for planning tactics of active surveillance and focal therapy.

  19. Digital reconstructed radiography quality control with software methods

    Science.gov (United States)

    Denis, Eloise; Beaumont, Stephane; Guedon, JeanPierre

    2005-04-01

    Nowadays, most of treatments for external radiotherapy are prepared with Treatment Planning Systems (TPS) which uses a virtual patient generated by a set of transverse slices acquired with a CT scanner of the patient in treatment position 1 2 3. In the first step of virtual simulation, the TPS is used to define a ballistic allowing a good target covering and the lowest irradiation for normal tissues. This parameters optimisation of the treatment with the TPS is realised with particular graphic tools allowing to: ×Contour the target, ×Expand the limit of the target in order to take into account contouring uncertainties, patient set up errors, movements of the target during the treatment (internal movement of the target and external movement of the patient), and beam's penumbra, ×Determine beams orientation and define dimensions and forms of the beams, ×Visualize beams on the patient's skin and calculate some characteristic points which will be tattooed on the patient to assist the patient set up before treating, ×Calculate for each beam a Digital Reconstructed Radiography (DRR) consisting in projecting the 3D CT virtual patient and beam limits with a cone beam geometry onto a plane. These DRR allow one for insuring the patient positioning during the treatment, essentially bone structures alignment by comparison with real radiography realized with the treatment X-ray source in the same geometric conditions (portal imaging). Then DRR are preponderant to insure the geometric accuracy of the treatment. For this reason quality control of its computation is mandatory4 . Until now, this control is realised with real test objects including some special inclusions4 5 . This paper proposes to use some numerical test objects to control the quality DRR calculation in terms of computation time, beam angle, divergence and magnification precision, spatial and contrast resolutions. The main advantage of this proposed method is to avoid a real test object CT acquisition

  20. K-type geomagnetic index nowcast with data quality control

    Directory of Open Access Journals (Sweden)

    René Warnant

    2011-07-01

    Full Text Available

    A nowcast system for operational estimation of a proxy K-type geomagnetic index is presented. The system is based on a fully automated computer procedure for real-time digital magnetogram data acquisition that includes screening of the dataset and removal of the outliers, estimation of the solar regular variation (SR of the geomagnetic field, calculation of the index, and issuing of an alert if storm-level activity is indicated. This is a time-controlled (rather than event-driven system that delivers the regular output of: the index value, the estimated quality flag, and eventually, an alert. The novel features provided are first, the strict control of the data input and processing, and second, the increased frequency of production of the index (every 1 h. Such quality control and increased time resolution have been found to be of crucial importance for various applications, e.g. ionospheric monitoring, that are of particular interest to us and to users of our service. The nowcast system operability, accuracy and precision have been tested with instantaneous measurements from recent years. A statistical comparison between the nowcast and the definitive index values shows that the average root-mean-square error is smaller than 1 KU. The system is now operational at the site of the Geophysical Centre of the Royal Meteorological Institute in Dourbes (50.1ºN, 4.6ºE, and it is being used for alerting users when geomagnetic storms take place.