WorldWideScience

Sample records for biological dosimetry methods

  1. The method validation step of biological dosimetry accreditation process

    International Nuclear Information System (INIS)

    Roy, L.; Voisin, P.A.; Guillou, A.C.; Busset, A.; Gregoire, E.; Buard, V.; Delbos, M.; Voisin, Ph.

    2006-01-01

    One of the missions of the Laboratory of Biological Dosimetry (L.D.B.) of the Institute for Radiation and Nuclear Safety (I.R.S.N.) is to assess the radiological dose after an accidental overexposure suspicion to ionising radiation, by using radio-induced changes of some biological parameters. The 'gold standard' is the yield of dicentrics observed in patients lymphocytes, and this yield is converted in dose using dose effect relationships. This method is complementary to clinical and physical dosimetry, for medical team in charge of the patients. To obtain a formal recognition of its operational activity, the laboratory decided three years ago, to require an accreditation, by following the recommendations of both 17025 General Requirements for the Competence of Testing and Calibration Laboratories and 19238 Performance criteria for service laboratories performing biological dosimetry by cyto-genetics. Diagnostics, risks analysis were realized to control the whole analysis process leading to documents writing. Purchases, personnel department, vocational training were also included in the quality system. Audits were very helpful to improve the quality system. One specificity of this technique is that it is not normalized therefore apart from quality management aspects, several technical points needed some validations. An inventory of potentially influent factors was carried out. To estimate their real effect on the yield of dicentrics, a Placket-Burman experimental design was conducted. The effect of seven parameters was tested: the BUdr (bromodeoxyuridine), PHA (phytohemagglutinin) and colcemid concentration, the culture duration, the incubator temperature, the blood volume and the medium volume. The chosen values were calculated according to the uncertainties on the way they were measured i.e. pipettes, thermometers, test tubes. None of the factors has a significant impact on the yield of dicentrics. Therefore the uncertainty linked to their use was considered as

  2. The method validation step of biological dosimetry accreditation process

    Energy Technology Data Exchange (ETDEWEB)

    Roy, L.; Voisin, P.A.; Guillou, A.C.; Busset, A.; Gregoire, E.; Buard, V.; Delbos, M.; Voisin, Ph. [Institut de Radioprotection et de Surete Nucleaire, LDB, 92 - Fontenay aux Roses (France)

    2006-07-01

    One of the missions of the Laboratory of Biological Dosimetry (L.D.B.) of the Institute for Radiation and Nuclear Safety (I.R.S.N.) is to assess the radiological dose after an accidental overexposure suspicion to ionising radiation, by using radio-induced changes of some biological parameters. The 'gold standard' is the yield of dicentrics observed in patients lymphocytes, and this yield is converted in dose using dose effect relationships. This method is complementary to clinical and physical dosimetry, for medical team in charge of the patients. To obtain a formal recognition of its operational activity, the laboratory decided three years ago, to require an accreditation, by following the recommendations of both 17025 General Requirements for the Competence of Testing and Calibration Laboratories and 19238 Performance criteria for service laboratories performing biological dosimetry by cyto-genetics. Diagnostics, risks analysis were realized to control the whole analysis process leading to documents writing. Purchases, personnel department, vocational training were also included in the quality system. Audits were very helpful to improve the quality system. One specificity of this technique is that it is not normalized therefore apart from quality management aspects, several technical points needed some validations. An inventory of potentially influent factors was carried out. To estimate their real effect on the yield of dicentrics, a Placket-Burman experimental design was conducted. The effect of seven parameters was tested: the BUdr (bromodeoxyuridine), PHA (phytohemagglutinin) and colcemid concentration, the culture duration, the incubator temperature, the blood volume and the medium volume. The chosen values were calculated according to the uncertainties on the way they were measured i.e. pipettes, thermometers, test tubes. None of the factors has a significant impact on the yield of dicentrics. Therefore the uncertainty linked to their use was

  3. Neutron dosimetry in biology

    International Nuclear Information System (INIS)

    Sigurbjoernsson, B.; Smith, H.H.; Gustafsson, A.

    1965-01-01

    To study adequately the biological effects of different energy neutrons it is necessary to have high-intensity sources which are not contaminated by other radiations, the most serious of which are gamma rays. An effective dosimetry must provide an accurate measure of the absorbed dose, in biological materials, of each type of radiation at any reactor facility involved in radiobiological research. A standardized biological dosimetry, in addition to physical and chemical methods, may be desirable. The ideal data needed to achieve a fully documented dosimetry has been compiled by H. Glubrecht: (1) Energy spectrum and intensity of neutrons; (2) Angular distribution of neutrons on the whole surface of the irradiated object; (3) Additional undesired radiation accompanying the neutrons; (4) Physical state and chemical composition of the irradiated object. It is not sufficient to note only an integral dose value (e.g. in 'rad') as the biological effect depends on the above data

  4. Usefulness and limits of biological dosimetry based on cytogenetic methods

    International Nuclear Information System (INIS)

    Leonard, A.; Rueff, J.; Gerber, G. B.; Leonard, E. D.

    2005-01-01

    Damage from occupational or accidental exposure to ionising radiation is often assessed by monitoring chromosome aberrations in peripheral blood lymphocytes, and these procedures have, in several cases, assisted physicians in the management of irradiated persons. Thereby, circulating lymphocytes, which are in the G0 stage of the cell cycle are stimulated with a mitogenic agent, usually phytohaemagglutinin, to replicate in vitro their DNA and enter cell division, and are then observed for abnormalities. Comparison with dose response relationships obtained in vitro allows an estimate of exposure based on scoring: - Unstable aberrations by the conventional, well-established analysis of metaphases for chromosome abnormalities or for micronuclei; - So-called stable aberrations by the classical G-banding (Giemsa-Stain-banding) technique or by the more recently developed fluorescent in situ hybridisation (FISH) method using fluorescent-labelled probes for centromeres and chromosomes. Three factors need to be considered in applying such biological dosimetry: (1) Radiation doses in the body are often inhomogeneous. A comparison of the distribution of the observed aberrations among with that expected from a normal poisson distribution can allow conclusions to be made with regard to the inhomogeneity of exposure by means of the so-called contaminated poisson distribution method; however, its application requires a sufficiently large number of aberrations, i.e. an exposure to a rather large dose at a high dose rate. (2) Exposure can occur at a low dose rate (e.g. from spread or lost radioactive sources) rendering a comparison with in vitro exposure hazardous. Dose-effect relationships of most aberrations that were scored, such as translocations, follow a square law. Repair intervening during exposure reduces the quadratic component with decreasing dose rate as exposure is spread over a longer period of time. No valid solution for this problem has yet been developed, although

  5. Dosimetry methods

    DEFF Research Database (Denmark)

    McLaughlin, W.L.; Miller, A.; Kovacs, A.

    2003-01-01

    Chemical and physical radiation dosimetry methods, used for the measurement of absorbed dose mainly during the practical use of ionizing radiation, are discussed with respect to their characteristics and fields of application....

  6. Biological dosimetry methods and their application in the Czech Army

    International Nuclear Information System (INIS)

    Zarybnicka, Lenka; Sinkorova, Zuzana; Pejchal, Jaroslav; Vilasova, Zdena

    2009-01-01

    Biodosimetric methods estimate the absorbed dose based on the irradiated body's individual response. Cytological, cytogenetic, and molecular methods are employed, each having its assets and shortcomings. The diagnosis of acute radiation sickness and the medical care of irradiated and/or contaminated individuals in the Czech Army are based on 5 basic indicators: dosimetric data, radiation history, type and intensity of prodromal signs, laboratory tests, and radiation dermatitis. Based on those indicators the affected individuals and categorized on-site into evacuation priority classes. The need for a rapid absorbed dose determination in the field environment is also associated with the requirement of a minimal laboratory and personnel background.

  7. Radiation effects analysis in a group of interventional radiologists using biological and physical dosimetry methods

    Energy Technology Data Exchange (ETDEWEB)

    Ramos, M., E-mail: WEMLmirapas@iqn.upv.e [Department of Chemical and Nuclear Engineering, Polytechnic University of Valencia, Camino de Vera s/n, 46022 Valencia (Spain); Montoro, A.; Almonacid, M. [Radiation Protection Service, Hospital Universitario La Fe Valencia (Spain); Ferrer, S. [Department of Chemical and Nuclear Engineering, Polytechnic University of Valencia, Camino de Vera s/n, 46022 Valencia (Spain); Barquinero, J.F. [Biological Dosimetry Service, Unit of Anthropology, Department of Animal and Vegetable Biology and Ecology, Universitat Autonoma de Barcelona (UAB) (Spain); Tortosa, R. [Radiation Protection Service, Hospital Universitario La Fe Valencia (Spain); Verdu, G. [Department of Chemical and Nuclear Engineering, Polytechnic University of Valencia, Camino de Vera s/n, 46022 Valencia (Spain); Rodriguez, P. [Biological Dosimetry Service, Unit of Anthropology, Department of Animal and Vegetable Biology and Ecology, Universitat Autonoma de Barcelona (UAB) (Spain); Barrios, L.L. [Department of Physiology and Cellular Biology, Unit of Cellular Biology (UAB) (Spain); Villaescusa, J.I. [Radiation Protection Service, Hospital Universitario La Fe Valencia (Spain)

    2010-08-15

    Interventional radiologists and staff members are frequently exposed to protracted and fractionated low doses of ionizing radiation, which extend during all their professional activities. These exposures can derive, due to the effects of direct and scattered radiation, in deterministic effects (radiodermitis, aged skin, cataracts, telangiectasia in nasal region, vasocellular epitelioms, hands depilation) and/or stochastic ones (cancer incidence). A methodology has been proposed for estimating the radiation risk or detriment from a group of six exposed interventional radiologists of the Hospital Universitario La Fe (Valencia, Spain), which had developed general exposition symptoms attributable to deterministic effects of ionizing radiation. Equivalent doses have been periodically registered using TLD's and wrist dosimeters, H{sub p}(10) and H{sub p}(0.07), respectively, and estimated through the observation of translocations in lymphocytes of peripheral blood (biological methods), by extrapolating the yield of translocations to their respective dose-effect curves. The software RADRISK has been applied for estimating radiation risks in these occupational radiation exposures. This software is based on transport models from epidemiological studies of population exposed to external sources of ionizing radiation, such as Hiroshima and Nagasaki atomic bomb survivors [UNSCEAR, Sources and effects of ionizing radiation: 2006 report to the general assembly, with scientific annexes. New York: United Nations; 2006]. The minimum and maximum average excess ratio for skin cancer has been, using wrist physical doses, of [1.03x10{sup -3}, 5.06x10{sup -2}], concluding that there is not an increased risk of skin cancer incidence. The minimum and maximum average excess ratio for leukemia has been, using TLD physical doses, of [7.84x10{sup -2}, 3.36x10{sup -1}], and using biological doses, of [1.40x10{sup -1}, 1.51], which is considerably higher than incidence rates, showing an

  8. Biological dosimetry of irradiation accidents

    International Nuclear Information System (INIS)

    Durand, V.; Chambrette, V.; Le Roy, A.; Paillole, N.; Sorokine, I.; Voisin, P.

    1994-01-01

    The biological dosimetry in radiation protection allows to evaluate the received dose by a potentially irradiated person from biological markers such chromosomal abnormalities. The technologies of Hybridization In Situ by Fluorescence (F.I.S.H) allow the detection of steady chromosomal aberrations of translocation type

  9. Development of radiation biological dosimetry

    International Nuclear Information System (INIS)

    Cho, Chul Koo; Kim, Tae Hwan; Lee, Yun Sil; Son, Young Sook; Kim, Soo Kwan; Jang, Won Suk; Le, Sun Joo; Jee, Young Heun; Jung, Woo Jung

    1999-04-01

    Up until now, only a few methods have been developed for radiation biological dosimetry such as conventional chromosome aberration and micronucleus in peripheral blood cell. However, because these methods not only can be estimated by the expert, but also have a little limitation due to need high technique and many times in the case of radiation accident, it is very difficult to evaluate the absorbed dose of victims. Therefore, we should develop effective, easy, simple and rapid biodosimetry and its guideline (triage) to be able to be treated the victims as fast as possible. We established the premature chromosome condensation assay and apoptotic fragment assay which was the significant relationship between dose and cell damages to evaluate the irradiation dose as correct and rapid as possible using lymphocytes and crypt cells, and compared with conventional chromosome aberration assay and micronuclei assay

  10. Development of radiation biological dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Chul Koo; Kim, Tae Hwan; Lee, Yun Sil; Son, Young Sook; Kim, Soo Kwan; Jang, Won Suk; Le, Sun Joo; Jee, Young Heun; Jung, Woo Jung

    1999-04-01

    Up until now, only a few methods have been developed for radiation biological dosimetry such as conventional chromosome aberration and micronucleus in peripheral blood cell. However, because these methods not only can be estimated by the expert, but also have a little limitation due to need high technique and many times in the case of radiation accident, it is very difficult to evaluate the absorbed dose of victims. Therefore, we should develop effective, easy, simple and rapid biodosimetry and its guideline (triage) to be able to be treated the victims as fast as possible. We established the premature chromosome condensation assay and apoptotic fragment assay which was the significant relationship between dose and cell damages to evaluate the irradiation dose as correct and rapid as possible using lymphocytes and crypt cells, and compared with conventional chromosome aberration assay and micronuclei assay.

  11. Light scattering by irradiated cells as a method of biological dosimetry

    International Nuclear Information System (INIS)

    Ostashevsky, J.

    1984-01-01

    Light scattering (LS) parameters between 350-500 nm wavelength have been studied for 2 groups of cells: 1) blood (BL) and thymus (TL) lymphocytes of rats and mice, and 2) Ehrlich ascite tumor (EAT) cells. LS measurements of freshly prepared cell suspensions have been made 24 hrs after x-ray irradiation of rodents (250 Kev, HVL = 2 mm Cu) at doses of 50-900 cGy. A steep (30% per Gy) linear (50-800 cGy for TL and 50-400 cGy for BL) dose-dependence was obtained for the increase in 90 0 -angle LS intensity. Increase in absorption (low-angle LS) was also linear (50-800 cGy for TL and BL) but less steep (9% per Gy). Irradiated cells were the same size as unirradiated. Changes in LS for TL and BL appear to follow the appearance of additional vacuoles which may become new internal smaller-size centers of LS. This suggestion is supported by direct observations of cells with dark-field microscopy. For EAT cells, both 90 0 and low angle LS had the same slope. This slope (4% per Gy) is much shallower than that for BL and TL, and quantitatively coincides with enlargement of area of EAT cells, which could explain LS changes. The difference in LS behavior of the two cellular groups reflects a difference in their early response to irradiation: interphase death for TL and BL, vs division delay for EAT cells. The above data suggest the fast and simple method of biological dosimetry

  12. Biological dosimetry intercomparison exercise: an evaluation of Triage and routine mode results by robust methods

    International Nuclear Information System (INIS)

    Di Giorgio, M.; Vallerga, M.B.; Radl, A.; Taja, M.R.; Barquinero, J.F.; Seoane, A.; De Luca, J.; Guerrero Carvajal, Y.C.; Stuck Oliveira, M.S.; Valdivia, P.; García Lima, O.; Lamadrid, A.; González Mesa, J.; Romero Aguilera, I.; Mandina Cardoso, T.; Arceo Maldonado, C.; Espinoza, M.E.; Martínez López, W.; Lloyd, D.C.; Méndez Acuña, L.; Di Tomaso, M.V.; Roy, L.; Lindholm, C.; Romm, H.; Güçlü, I.

    2011-01-01

    Well-defined protocols and quality management standards are indispensable for biological dosimetry laboratories. Participation in periodic proficiency testing by interlaboratory comparisons is also required. This harmonization is essential if a cooperative network is used to respond to a mass casualty event. Here we present an international intercomparison based on dicentric chromosome analysis for dose assessment performed in the framework of the IAEA Regional Latin American RLA/9/054 Project. The exercise involved 14 laboratories, 8 from Latin America and 6 from Europe. The performance of each laboratory and the reproducibility of the exercise were evaluated using robust methods described in ISO standards. The study was based on the analysis of slides from samples irradiated with 0.75 (DI) and 2.5 Gy (DII). Laboratories were required to score the frequency of dicentrics and convert them to estimated doses, using their own dose-effect curves, after the analysis of 50 or 100 cells (triage mode) and after conventional scoring of 500 cells or 100 dicentrics. In the conventional scoring, at both doses, all reported frequencies were considered as satisfactory, and two reported doses were considered as questionable. The analysis of the data dispersion among the dicentric frequencies and among doses indicated a better reproducibility for estimated doses (15.6% for DI and 8.8% for DII) than for frequencies (24.4% for DI and 11.4% for DII), expressed by the coefficient of variation. In the two triage modes, although robust analysis classified some reported frequencies or doses as unsatisfactory or questionable, all estimated doses were in agreement with the accepted error of ±0.5 Gy. However, at the DI dose and for 50 scored cells, 5 out of the 14 reported confidence intervals that included zero dose and could be interpreted as false negatives. This improved with 100 cells, where only one confidence interval included zero dose. At the DII dose, all estimations fell within

  13. Analysis and assessment of the detriment in interventional radiology using biological dosimetry methods

    International Nuclear Information System (INIS)

    Montoro, A.; Almonacid, M.; Villaescusa, J.I.; Barquinero, J.F.; Rodriguez, P.; Barrios, L.; Verdu, G.; Ramos, M.

    2006-01-01

    Interventional radiologist and staff members usually are exposed to high levels of scattered radiation. As a result, the exposition to radiation procedures can produce detrimental effects that we would have to know. Effective dose is the quantity that better estimates the radiation risk. For this study we have realized an estimation of the radiological detriment to exposed workers of the Hospital la Fe de Valencia. For it, have been used physical doses registered in detectors T.L.D., and doses estimated by biological dosimetry in lymphocytes of peripheral blood. There has been estimated for every case the probability of effect of skin cancer and of non-solid cancers (leukaemia, lymphoma and myeloma), being compared with the baseline probability of natural effect. Biological doses were obtained by extrapolating the yield of dicentrics and translocations to their respective dose -effect curves. The discrepancies observed between physically recorded doses and biological estimated doses indicate that workers did not always wear their dosimeters or the dosimeters were not always in the radiation field. Cytogenetic studies should be extended to more workers to assess the risk derived from their occupational exposure. (authors)

  14. Analysis and assessment of the detriment in interventional radiology using biological dosimetry methods

    Energy Technology Data Exchange (ETDEWEB)

    Montoro, A.; Almonacid, M.; Villaescusa, J.I. [Hospital Univ. la Fe de Valen cian, Servicio de Proteccion Radiologica, Valencia (Spain); Barquinero, J.F.; Rodriguez, P. [Universitat Autonom a de Barcelona, Servicio de Dosimetria Biologica, Unidad de Antropologia, Departamento de Biologia Animal, Vegetal y Ecologia., Barcelona (Spain); Barrios, L. [Universidad Autonoma de Barcelona, Dept. de Biologia Celular y Fisiologia. Unidad de Biologia Celular, Barcelona (Spain); Verdu, G.; Ramos, M. [Universidad Politecnica de Valencia, Dept. de Ingenieria Quimica y Nuclear, Valencia, (Spain)

    2006-07-01

    Interventional radiologist and staff members usually are exposed to high levels of scattered radiation. As a result, the exposition to radiation procedures can produce detrimental effects that we would have to know. Effective dose is the quantity that better estimates the radiation risk. For this study we have realized an estimation of the radiological detriment to exposed workers of the Hospital la Fe de Valencia. For it, have been used physical doses registered in detectors T.L.D., and doses estimated by biological dosimetry in lymphocytes of peripheral blood. There has been estimated for every case the probability of effect of skin cancer and of non-solid cancers (leukaemia, lymphoma and myeloma), being compared with the baseline probability of natural effect. Biological doses were obtained by extrapolating the yield of dicentrics and translocations to their respective dose -effect curves. The discrepancies observed between physically recorded doses and biological estimated doses indicate that workers did not always wear their dosimeters or the dosimeters were not always in the radiation field. Cytogenetic studies should be extended to more workers to assess the risk derived from their occupational exposure. (authors)

  15. Reconstruction of absorbed dose by methods biological dosimetry inhabitans living in Semipalatinsk Nuclear Test Site

    International Nuclear Information System (INIS)

    Abildinova, G.

    2010-01-01

    As a result perennial overland and atmospheric test the nucleus weapon on Semipalatinsk nucler test site (NTS) about 1,2 ml person were subjected to frequentative sharp and chronic irradiation in different range of doses. Besides a significant number of battle radioactive matters tests with radionuclei dispersion on soil surface and an atmosphere was realized also. All this activity has caused the significant radioactive contamination and damage to an environment, and the local population has received extra exposure to radiation. These circumstances have essentially complicated the economy development of the given region. Aim: Reconstruction of absorbed dose by modern methods biological dosimetry beside inhabitants living in region of influence Semipalatinsk NTS. The cytogenetically examination of population Semipalatinsk region, living in different zones radiation risk: s. Dolon, s. Sarzhal, s. Mostik. Installed that total frequency of chromosome aberrations forms 4,8/100; 2,1/100; 2,5/100 cells, accordingly. High level of chromosome aberrations is conditioned to account radiations markers - acentric fragments (2,1/100 cells in s. Dolon; 1,09/100 cells in s. Sarzhal; 0,79/100 cells in s. Mostik); dysenteric and ring chromosomes (0,6; 0,2; 0,11) and stable type chromosome aberrations (1,02; 0,3; 1,0, accordingly). Frequency and spectrum of chromosome aberrations are indicative of significant mutation action ionizing radiations on chromosome device of somatic cells. Studied dependency an cytogenetically of effects from dose of irradiation within before 0,5 Gr in vitro for calibrated curve standard when undertaking reconstruction efficient dose at the time of irradiations examined group of population. Dependency is described the model a*cos(x) 1 + sin (x), where x - correlation a dysenteric and ring chromosomes to acentric fragments. Dependence of cytogenetic parameters upon ESR-doses had been studied. Had been received dependences: for the total frequency of

  16. The Latin American Biological Dosimetry Network (LBDNet)

    International Nuclear Information System (INIS)

    Garcia, O.; Lamadrid, A.I.; Gonzalez, J.E.; Romero, I.; Mandina, T.; Di Giorgio, M.; Radl, A.; Taja, M.R.; Sapienza, C.E.; Deminge, M.M.; Fernandez Rearte, J.; Stuck Oliveira, M.; Valdivia, P.; Guerrero-Carbajal, C.; Arceo Maldonado, C.; Cortina Ramirez, G.E.; Espinoza, M.; Martinez-Lopez, W.; Di Tomasso, M.

    2016-01-01

    Biological Dosimetry is a necessary support for national radiation protection programmes and emergency response schemes. The Latin American Biological Dosimetry Network (LBDNet) was formally founded in 2007 to provide early biological dosimetry assistance in case of radiation emergencies in the Latin American Region. Here are presented the main topics considered in the foundational document of the network, which comprise: mission, partners, concept of operation, including the mechanism to request support for biological dosimetry assistance in the region, and the network capabilities. The process for network activation and the role of the coordinating laboratory during biological dosimetry emergency response is also presented. This information is preceded by historical remarks on biological dosimetry cooperation in Latin America. A summary of the main experimental and practical results already obtained by the LBDNet is also included. (authors)

  17. The Latin American Biological Dosimetry Network (LBDNet).

    Science.gov (United States)

    García, O; Di Giorgio, M; Radl, A; Taja, M R; Sapienza, C E; Deminge, M M; Fernández Rearte, J; Stuck Oliveira, M; Valdivia, P; Lamadrid, A I; González, J E; Romero, I; Mandina, T; Guerrero-Carbajal, C; ArceoMaldonado, C; Cortina Ramírez, G E; Espinoza, M; Martínez-López, W; Di Tomasso, M

    2016-09-01

    Biological Dosimetry is a necessary support for national radiation protection programmes and emergency response schemes. The Latin American Biological Dosimetry Network (LBDNet) was formally founded in 2007 to provide early biological dosimetry assistance in case of radiation emergencies in the Latin American Region. Here are presented the main topics considered in the foundational document of the network, which comprise: mission, partners, concept of operation, including the mechanism to request support for biological dosimetry assistance in the region, and the network capabilities. The process for network activation and the role of the coordinating laboratory during biological dosimetry emergency response is also presented. This information is preceded by historical remarks on biological dosimetry cooperation in Latin America. A summary of the main experimental and practical results already obtained by the LBDNet is also included. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  18. Calibration curves for biological dosimetry

    International Nuclear Information System (INIS)

    Guerrero C, C.; Brena V, M. . E-mail cgc@nuclear.inin.mx

    2004-01-01

    The generated information by the investigations in different laboratories of the world, included the ININ, in which settles down that certain class of chromosomal leisure it increases in function of the dose and radiation type, has given by result the obtaining of calibrated curves that are applied in the well-known technique as biological dosimetry. In this work is presented a summary of the work made in the laboratory that includes the calibrated curves for gamma radiation of 60 Cobalt and X rays of 250 k Vp, examples of presumed exposure to ionizing radiation, resolved by means of aberration analysis and the corresponding dose estimate through the equations of the respective curves and finally a comparison among the dose calculations in those people affected by the accident of Ciudad Juarez, carried out by the group of Oak Ridge, USA and those obtained in this laboratory. (Author)

  19. Dosimetry and biological effects of fast neutrons

    International Nuclear Information System (INIS)

    Zoetelief, J.

    1981-01-01

    This thesis contains studies on two types of cellular damage: cell reproductive death and chromosome aberrations induced by irradiation with X rays, gamma rays and fast neutrons of different energies. A prerequisite for the performance of radiobiological experiments is the determination of the absorbed dose with a sufficient degree of accuracy and precision. Basic concepts of energy deposition by ionizing radiation and practical aspects of neutron dosimetry for biomedical purposes are discussed. Information on the relative neutron sensitivity of GM counters and on the effective point of measurement of ionization chambers for dosimetry of neutron and photon beams under free-in-air conditions and inside phantoms which are used to simulate the biological objects is presented. Different methods for neutron dosimetry are compared and the experimental techniques used for the investigations of cell reproductive death and chromosome aberrations induced by ionizing radiation of different qualities are presented. Dose-effect relations for induction cell inactivation and chromsome aberrations in three cultured cell lines for different radiation qualities are presented. (Auth.)

  20. The use of apoptosis in human lymphocytes peripheral as alternative methods in biological dosimetry of radiation effects from cobalt-60

    International Nuclear Information System (INIS)

    Lemes, Marisa

    1997-01-01

    Gamma rays affect cells in dose-response manner, resulting in cell death, as in cancer radiotherapy. The ionizing radiation acts by transferring energy, mainly by free radicals from water radiolysis that result in nucleic acid damage and other effects in lipids and proteins, The level of exposure is indirectly estimated by physical dosimetry, but the biological dosimetry can measure the direct radiation effect, mainly in post-dividing cells by classical cytogenetic approach. Recently, it was reported that irradiated cells develop an induced programmed death or apoptosis. With a biological dosimetric technique, we measured apoptotic cell fraction in 60 Co in vitro irradiated blood cells from voluntary healthy donors. The agarose gel electrophoresis showed a low sensitivity, because cell DNA presented the characteristic pattern only when the cells were exposed to 100 c Gy or more. Using a terminal DNA labeling technique we observed that the apoptotic cell fraction proportionally increases with irradiation. Similar sensitivity was observed when compared to classical cytogenetics (3 c Gy minimum detection level). These techniques are easier to perform, do not need cell culture and all cells, including interphase ones, can be analyzed, providing a good tool in biological dosimetry. (author)

  1. About the factors distorting biological dosimetry results

    International Nuclear Information System (INIS)

    Mosseh, I.B.

    1999-01-01

    The row of chemical substances that have not mutagenic effect can strengthen ionising radiation induced cytogenetic effects. For example nitrite sodium and nitrate sodium reinforce mutagenic action of radiation and cause sensitized effect although they aren't mutagens. Presence of residual amount of herbicides in food products can have influence at level of aberration in human cells. It was investigated the influence of herbicide zencor at mutagenic action of radiation. This substance has weak mutagenic activity. In the case of combined action of zencor with irradiation antagonistic effect was observed. Mutation rate turns out to be lower than expected summary value. At the same time many foods products (tea, coffee, cacao, chocolate etc., which contain melanin) are antimutagens and can also change the frequency of radiation induced mutations. Taking of medicine distort the results of dose estimation. The frequency of chromosomal aberrations in blood lymphocytes after acute irradiation is considered to be adequate method of biological dosimetry. In the case of chronic irradiation this analysis becomes complicated with such processes as adaptation (selection and proliferation of cells with more radioresistant genotype) and the origin of genetic un stability which leads to higher radiosensitivity. The estimation of the level of point mutations is the most precise method of biological dosimetry because their existence is less exposed to modifications

  2. Biological dosimetry of local radiation accidents of skin: possible cytological and biochemical methods

    International Nuclear Information System (INIS)

    Potten, C.S.

    1986-01-01

    Skin erythema or skin reaction is a highly dose-dependent change in skin appearance. A few gray can usually be detected in humans but higher doses are usually required for experimental rodents. The disadvantages are that the end-point is subjective and the response strongly influenced by numerous physical and biological factors. Changes in the levels of pigmentation can be detected in the epidermis and possibly the hair follicles but generally these only become apparent after chronic exposures. The skin appendages, particularly the hair follicles, could represent sensitive systems for detecting radiation exposures, but the cyclic behaviour of the hair follicles is difficult to control or determine in an accident. Acute cell death can be measured in the follicle germ and changes in the thickness and appearance of the hair are easily detected: in severe cases there is loss of hair (epilation). The number of dead cells per follicle section increased at a rate of 2.9/Gy and doses of about 0.2Gy can be easily detected. The width of the hair is reduced by about 7-8%/Gy and this change, which results in a dysplastic hair is believed to be the consequences of cell death in the follicles. (author)

  3. Establishing working standards of chromosome aberrations analysis for biological dosimetry

    International Nuclear Information System (INIS)

    Bui Thi Kim Luyen; Tran Que; Pham Ngoc Duy; Nguyen Thi Kim Anh; Ha Thi Ngoc Lien

    2015-01-01

    Biological dosimetry is an dose assessment method using specify bio markers of radiation. IAEA (International Atomic Energy Agency) and ISO (International Organization for Standardization) defined that dicentric chromosome is specify for radiation, it is a gold standard for biodosimetry. Along with the documents published by IAEA, WHO, ISO and OECD, our results of study on the chromosome aberrations induced by radiation were organized systematically in nine standards that dealing with chromosome aberration test and micronucleus test in human peripheral blood lymphocytes in vitro. This standard addresses: the reference dose-effect for dose estimation, the minimum detection levels, cell culture, slide preparation, scoring procedure for chromosome aberrations use for biodosimetry, the criteria for converting aberration frequency into absorbed dose, reporting of results. Following these standards, the automatic analysis devices were calibrated for improving biological dosimetry method. This standard will be used to acquire and maintain accreditation of the Biological Dosimetry laboratory in Nuclear Research Institute. (author)

  4. Biological dosimetry, scopes and limitations

    International Nuclear Information System (INIS)

    Guerrero C, C.; Brena V, M.

    1999-01-01

    The analysis of the aberrations in chromosomes is an alternative to establish the exposure dose to the radiation, when the information provided by the traditional physical methods is insufficient. There are diverse causes by which it can reached to apply an alternative system, such is the case of exposures of another persons to the management of radiation sources, which not carry physical dosemeter. Contrary case is to the occupational exposure personnel (OEP), what must to utilize some system for determining the exposure dose, even so can be needed the case for more information. In any case, the cells from the affected person are the alternative without the biological system be overlap to the physical, it is complementary. (Author)

  5. DRDC Ottawa working standard for biological dosimetry

    International Nuclear Information System (INIS)

    Segura, T.M.; Prud'homme-Lalonde, L.; Thorleifson, E.; Lachapelle, S.; Mullins, D.; Qutob, S.; Wilkinson, D.

    2005-07-01

    This Standard provides quality assurance, quality control, and evaluation of the performance criteria for the purpose of accreditation of the Radiation Biology laboratory at Defence Research and Development Canada - Ottawa (DRDC Ottawa) using biological dosimetry to predict radiation exposure doses. The International Standard (ISO 19238) and the International Atomic Energy Association (IAEA) Technical Report Series No. 405 are used as guiding documents in preparation of this working document specific to the DRDC Ottawa Radiation Biology Laboratory. This Standard addresses: 1. The confidentiality of personal information, for the customer and the service laboratory; 2. The laboratory safety requirements; 3. The calibration sources and calibration dose ranges useful for establishing the reference dose-effect curves allowing the dose estimation from chromosome aberration frequency, and the minimum detection levels; 4. Transportation criteria for shipping of test samples to the laboratory; 5. Preparation of samples for analysis; 6. The scoring procedure for unstable chromosome aberrations used for biological dosimetry; 7. The criteria for converting a measured aberration frequency into an estimate of absorbed dose; 8. The reporting of results; 9. The quality assurance and quality control plan for the laboratory; and 10. Informative annexes containing examples of a questionnaire, instructions for customers, a data sheet for recording aberrations, a sample report and other supportive documents. (author)

  6. DRDC Ottawa working standard for biological dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Segura, T M; Prud' homme-Lalonde, L [Defence Research and Development Canada, Ottawa, Ontario (Canada); Thorleifson, E [Health Canada, Gatineau, Quebec (Canada); Lachapelle, S; Mullins, D [JERA Consulting (Canada); Qutob, S [Health Canada, Gatineau, Quebec (Canada); Wilkinson, D

    2005-07-15

    This Standard provides quality assurance, quality control, and evaluation of the performance criteria for the purpose of accreditation of the Radiation Biology laboratory at Defence Research and Development Canada - Ottawa (DRDC Ottawa) using biological dosimetry to predict radiation exposure doses. The International Standard (ISO 19238) and the International Atomic Energy Association (IAEA) Technical Report Series No. 405 are used as guiding documents in preparation of this working document specific to the DRDC Ottawa Radiation Biology Laboratory. This Standard addresses: 1. The confidentiality of personal information, for the customer and the service laboratory; 2. The laboratory safety requirements; 3. The calibration sources and calibration dose ranges useful for establishing the reference dose-effect curves allowing the dose estimation from chromosome aberration frequency, and the minimum detection levels; 4. Transportation criteria for shipping of test samples to the laboratory; 5. Preparation of samples for analysis; 6. The scoring procedure for unstable chromosome aberrations used for biological dosimetry; 7. The criteria for converting a measured aberration frequency into an estimate of absorbed dose; 8. The reporting of results; 9. The quality assurance and quality control plan for the laboratory; and 10. Informative annexes containing examples of a questionnaire, instructions for customers, a data sheet for recording aberrations, a sample report and other supportive documents. (author)

  7. Chromosome aberration analysis for biological dosimetry: a review

    International Nuclear Information System (INIS)

    Paul, S.F.D.; Venkatachalam, P.; Jeevanram, R.K.

    1996-01-01

    Among various biological dosimetry techniques, dicentric chromosome aberration method appears to be the method of choice in analysing accidental radiation exposure in most of the laboratories. The major advantage of this method is its sensitivity as the number of dicentric chromosomes present in control population is too small and more importantly radiation induces mainly dicentric chromosome aberration among unstable aberration. This report brings out the historical development of various cytogenetic methods, the basic structure of DNA, chromosomes and different forms of chromosome aberrations. It also highlights the construction of dose-response curve for dicentric chromosome and its use in the estimation of radiation dose. (author)

  8. Modern methods of personnel dosimetry

    International Nuclear Information System (INIS)

    Kraus, W.; Herrmann, D.; Kiesewetter, W.

    The physical properties of radiation detectors for personnel dosimetry are described and compared. The suitability of different types of dosimeters for operational and central monitoring of normal occupational exposure, for accident and catastrophe dosimetry and for background and space-flight dosimetry is discussed. The difficulties in interpreting the dosimeter reading with respect to the dose in individual body organs are discussed briefly. 430 literature citations (up to Spring 1966) are given

  9. Dosimetry

    International Nuclear Information System (INIS)

    Rezende, D.A.O. de

    1976-01-01

    The fundamental units of dosimetry are defined, such as exposure rate, absorbed dose and equivalent dose. A table is given of relative biological effectiveness values for the different types of radiation. The relation between the roentgen and rad units is calculated and the concepts of physical half-life, biological half-life and effective half-life are discussed. Referring to internal dosimetry, a mathematical treatment is given to β particle-and γ radiation dosimetry. The absorbed dose is calculated and a practical example is given of the calculation of the exposure and of the dose rate for a gama source [pt

  10. Role of cytogenetic techniques in biological dosimetry of absorbed radiation

    International Nuclear Information System (INIS)

    Rao, B.S.

    2016-01-01

    In most of the radiation accidents, physical dosimetric information is rarely available. Further, most of the accidental exposures are non-uniform involving either partial body or localized exposure to significant doses. In such situations, physical dosimetry does not provide reliable dose estimate. It has now been realized that biological dosimetric techniques can play an important role in the assessment of absorbed dose. In recent years, a number of biological indicators of radiation have been identified. These include the kinetics of onset and persistence of prodromal syndromes (radiation sickness), cytogenetic changes in peripheral blood lymphocytes, hematological changes, biochemical indicators, ESR spectroscopy of biological samples, induction of gene mutations in red blood cells, cytogenetic and physiological changes in skin and neurophysiological changes. In general, dosimetric information is derived by a combination of several different methods, as they have potential to serve as prognostic indicators. The role of cytogenetic techniques in peripheral blood lymphocytes (PBL) as biological indicators of absorbed radiation is reviewed here

  11. Dosimetry Control: Technic and methods. Proceedings of the international workshop 'Actual problems of dosimetry'

    International Nuclear Information System (INIS)

    Lyutsko, A.M.; Nesterenko, V.B.; Chudakov, V.A.; Konoplya, E.F.; Milyutin, A.A.

    1997-10-01

    There is a number of unsolved problems of both dosimetric and radiometric control, questions of the biological dosimetry, reconstruction of dozes of irradiation of the population at radiation incidents, which require coordination of efforts of scientists in various areas of a science. The submitted materials are grouped on five units: dosimetry engineering, biological dosimetry and markers of radiation impact, dosimetry of a medical irradiation, normative and measurement assurance of the dosimetric control, monitoring and reconstruction of dozes at radiation incidents

  12. Statistical issues in biological radiation dosimetry for risk assessment using stable chromosome aberrations

    International Nuclear Information System (INIS)

    Cologne, J.B.; Preston, D.L.

    1998-01-01

    Biological dosimeters are useful for epidemiologic risk assessment in populations exposed to catastrophic nuclear events and as a means of validating physical dosimetry in radiation workers. Application requires knowledge of the magnitude of uncertainty in the biological dose estimates and an understanding of potential statistical pitfalls arising from their use. This paper describes the statistical aspects of biological dosimetry in general and presents a detailed analysis in the specific case of dosimetry for risk assessment using stable chromosome aberration frequency. Biological dose estimates may be obtained from a dose-response curve, but negative estimates can result and adjustment must be made for regression bias due to imprecise estimation when the estimates are used in regression analyses. Posterior-mean estimates, derived as the mean of the distribution of true doses compatible with a given value of the biological endpoint, have several desirable properties: they are nonnegative, less sensitive to extreme skewness in the true dose distribution, and implicitly adjusted to avoid regression bias. The methods necessitate approximating the true-dose distribution in the population in which biological dosimetry is being applied, which calls for careful consideration of this distribution through other information. An important question addressed here is to what extent the methods are robust to misspecification of this distribution, because in many applications of biological dosimetry it cannot be characterized well. The findings suggest that dosimetry based solely on stable chromosome aberration frequency may be useful for population-based risk assessment

  13. Cytogenetic biological dosimetry. Dose estimative in accidental exposure

    International Nuclear Information System (INIS)

    Santos, O.R. dos; Campos, I.M.A. de.

    1988-01-01

    The methodology of cytogenetic biological dosimetry is studied. The application in estimation of dose in five cases of accidental exposure is reported. An hematological study and culture of lymphocytes is presented. (M.A.C.) [pt

  14. Dosimetry

    International Nuclear Information System (INIS)

    Anon.

    1990-01-01

    The purpose of ionizing radiation dosimetry is the measurement of the physical and biological consequences of exposure to radiation. As these consequences are proportional to the local absorption of energy, the dosimetry of ionizing radiation is based on the measurement of this quantity. Owing to the size of the effects of ionizing radiation on materials in all of these area, dosimetry plays an essential role in the prevention and the control of radiation exposure. Its use is of great importance in two areas in particular where the employment of ionizing radiation relates to human health: radiation protection, and medical applications. Dosimetry is different for various reasons: owing to the diversity of the physical characteristics produced by different kinds of radiation according to their nature (X- and γ-photons, electrons, neutrons,...), their energy (from several keV to several MeV), the orders of magnitude of the doses being estimated (a factor of about 10 5 between diagnostic and therapeutic applications); and the temporal and spatial variation of the biological parameters entering into the calculations. On the practical level, dosimetry poses two distinct yet closely related problems: the determination of the absorbed dose received by a subject exposed to radiation from a source external to his body (external dosimetry); and the determination of the absorbed dose received by a subject owing to the presence within his body of some radioactive substance (internal dosimetry)

  15. Biological dosimetry of X-rays by micronuclei study

    International Nuclear Information System (INIS)

    Gomez, E.; Silva, A.; Navlet, J.

    1991-01-01

    Biological dosimetry consists of estimating absorbed doses for people exposed to radiation by mean biological methods. Several indicators used are based in hematological, biochemical an cytogenetics data, although nowadays without doubt, the cytogenetic method is considered to be the most reliable, in this case, the study of micronuclei in peripheral blood lymphocytes cytokinetic blocked can be related to absorbed dose through an experimental calibration curve. An experimental dose-response curve, using micronuclei assay for X-rays at 250 kVp, 43,79 rads/min and temperature 37 degree celsius has been produced. Experimental data is fitted to model Y=c+ α D+β D 2 where. Y is the number micronuclei per cell and D the dose. the curve is compared with those produced elsewhere

  16. Biological Dosimetry of X-rays by micronuclei study

    International Nuclear Information System (INIS)

    Gomez, E.; Silva, A.; Navlet, J.

    1991-01-01

    Biological dosimetry consists of estimating absorbed doses for people exposed to radiation by mean biological methods. Several indicators used are based in haematological, biochemical an cytogenetics data, although nowadays without doubt, the cytogenetic method is considered to be the most reliable, in this case, the study of micronuclei in peripheral blood lymphocytes citokinetics blocked can be related to absorbed dose through an experimental calibration curve. An experimental dose-response curve, using micronuclei assay for X-rays at 250 kVp, 43,79 rads/min and temperature 37 degree centigree has been produced. Experimental data is fitted to model Y=C+ αD+BD''2 where Y is the number of micronuclei per cell and D the dose. The curve is compared with those produced elsewhere. (Author) 24 refs

  17. Biological dosimetry of ionizing radiation by chromosomal aberration analysis

    International Nuclear Information System (INIS)

    Gonzalez-Castano, S.; Silva, A.; Navlet, J.

    1990-01-01

    Biological dosimetry consists of estimating absorbed doses for people exposed to radiation by mean biological methods. Several indicators used are based in haematological, biochemical, and cytogenetic data, although nowadays without doubt, the cytogenetic method is considered to be the most reliable. In this case, the study ol chromosomal aberrations, normally dicentric chromosomes, in peripheral lymphocytes can be related to absorbed dose through an experimental calibration curve. An experimental dose-response curve, using dicentric chromosomes analysis, X-rays at 300 kVp, 114 rad/min and temperature 37 degree celsius has been produced. Experimental data is fitted to model Y =α + β 1 D + β 2 D 2 , where Y is the number of dicentrics per cell and D the dose. The curve is compared with those produced elsewhere. (Author) 14 refs

  18. Biological dosimetry of ionizing radiation by chromosomal aberration analysis

    International Nuclear Information System (INIS)

    Navlet Armenta, J.M.; Gonzalez, S.; Silva, A.

    1990-01-01

    Biological dosimetry consists of estimating absorbed doses for people exposed to radiation by mean biological methods. Several indicators used are based in haemathological, biochemical, and cytogenetic data, although nowadays without doubt, the cytogenetic method is considered to be the most reliable. In this case, the study of chromosomal aberrations, normally dicentric chromosomes, in peripheral lymphocytes can be related to absorbed dose through an experimental calibration curve. An experimental dose-response curve using dicentric chromosomes analysis, X-rays at 300 kVp, 114 rad/min and temperature 37 o C has been produced. Experimental data is fitted to model Y = α+β 1 D+β 2 D 2 , where Y is the number of dicentrics per cell and D the dose. The curve is compared with those produced elsewhere. (Author)

  19. Integration of new biological and physical retrospective dosimetry methods into EU emergency response plans - joint RENEB and EURADOS inter-laboratory comparisons.

    Science.gov (United States)

    Ainsbury, Elizabeth; Badie, Christophe; Barnard, Stephen; Manning, Grainne; Moquet, Jayne; Abend, Michael; Antunes, Ana Catarina; Barrios, Lleonard; Bassinet, Celine; Beinke, Christina; Bortolin, Emanuela; Bossin, Lily; Bricknell, Clare; Brzoska, Kamil; Buraczewska, Iwona; Castaño, Carlos Huertas; Čemusová, Zina; Christiansson, Maria; Cordero, Santiago Mateos; Cosler, Guillaume; Monaca, Sara Della; Desangles, François; Discher, Michael; Dominguez, Inmaculada; Doucha-Senf, Sven; Eakins, Jon; Fattibene, Paola; Filippi, Silvia; Frenzel, Monika; Georgieva, Dimka; Gregoire, Eric; Guogyte, Kamile; Hadjidekova, Valeria; Hadjiiska, Ljubomira; Hristova, Rositsa; Karakosta, Maria; Kis, Enikő; Kriehuber, Ralf; Lee, Jungil; Lloyd, David; Lumniczky, Katalin; Lyng, Fiona; Macaeva, Ellina; Majewski, Matthaeus; Vanda Martins, S; McKeever, Stephen W S; Meade, Aidan; Medipally, Dinesh; Meschini, Roberta; M'kacher, Radhia; Gil, Octávia Monteiro; Montero, Alegria; Moreno, Mercedes; Noditi, Mihaela; Oestreicher, Ursula; Oskamp, Dominik; Palitti, Fabrizio; Palma, Valentina; Pantelias, Gabriel; Pateux, Jerome; Patrono, Clarice; Pepe, Gaetano; Port, Matthias; Prieto, María Jesús; Quattrini, Maria Cristina; Quintens, Roel; Ricoul, Michelle; Roy, Laurence; Sabatier, Laure; Sebastià, Natividad; Sholom, Sergey; Sommer, Sylwester; Staynova, Albena; Strunz, Sonja; Terzoudi, Georgia; Testa, Antonella; Trompier, Francois; Valente, Marco; Hoey, Olivier Van; Veronese, Ivan; Wojcik, Andrzej; Woda, Clemens

    2017-01-01

    RENEB, 'Realising the European Network of Biodosimetry and Physical Retrospective Dosimetry,' is a network for research and emergency response mutual assistance in biodosimetry within the EU. Within this extremely active network, a number of new dosimetry methods have recently been proposed or developed. There is a requirement to test and/or validate these candidate techniques and inter-comparison exercises are a well-established method for such validation. The authors present details of inter-comparisons of four such new methods: dicentric chromosome analysis including telomere and centromere staining; the gene expression assay carried out in whole blood; Raman spectroscopy on blood lymphocytes, and detection of radiation-induced thermoluminescent signals in glass screens taken from mobile phones. In general the results show good agreement between the laboratories and methods within the expected levels of uncertainty, and thus demonstrate that there is a lot of potential for each of the candidate techniques. Further work is required before the new methods can be included within the suite of reliable dosimetry methods for use by RENEB partners and others in routine and emergency response scenarios.

  20. Estimation of individual radiation doses determined by the biological dosimetry method at the inhabitants of the Chernobyl region

    International Nuclear Information System (INIS)

    Nikolaevich, L.N.

    1997-01-01

    The results obtained by the method of the chromosome aberration analysis in human peripheral blood lymphocytes are given. Hematologically healthy inhabitants of Vetka and Khoiniki districts in Gomel Region (80 adults and 38 children), as well as persons suffering from hemoblastosis (acute lymphoblastic leukemia, acute myeloblastic leukemia) were examined. 27258 metaphase cells being analysed. Only two-hit aberrations (dicentric and ring chromosomes with fragments and without them), specific disturbances in response to radiation effect, were tested for estimating an individual dose of ionizing radiation. The examined groups of adults and children were formed depending on the value of an individual radiation dose: 0 kGy; from 0 to 1,4 kGy and from 1,5 to 3,0 kGy. 39% of adults took the dose up to 1,5 kGy and about 9% did above 2,0 kGy. The tendency towards increasing the amount of aberrant lymphocytes in peripheral blood is observed in persons who took the dose above 2,0 kGy. Among children 52,6% took the doses from 1,5 to 3,0 kGy. No increase in the level of aberrant cells in comparison with the children from the 'zero group' was observed in those children. Apparently, in some cases slightly reduced radiation doses can be obtained by the data of the chromosome analysis method since with the time elimination of a portion of these cells with unstable chromosome aberrations takes place. Elimination of chromosome aberrations in lymphocytes can be caused by different infectious processes which are accompanied by a pronounced immune response inducing inclusion of lymphocytes with aberrations in mitosis and , as a result, disappearance of unstable mutations. However, together with elimination of old chromosome aberrations new ones, caused by ongoing radiation, emerge in people living in radio contaminated regions and thus, the radiation dose determined by the chromosome analysis method even increases with years that can favour rise in malignant tumors. The radiation dose

  1. Latinamerican Biological Dosimetry Network (LBDNET). International Biological Dosimetry intercomparison Program (exercise 2007-2008)

    International Nuclear Information System (INIS)

    Di Giorgio, Marina; Vallerga, Maria B.; Radl, A.; Taja, Maria R.

    2009-01-01

    This paper describes the International Biological Dosimetry Intercomparison Program (exercise 2007-2008) - developed within the framework of the IAEA regional project - RLA/9/054 (Establishment of national capabilities for response to radiological and nuclear emergency) whose general objectives are: assess reproducibility inter-laboratory; identify problems and provide the necessary modifications for collaborative work in accidental situations requiring activation of mutual assistance mechanisms which will form the basis of the Organization of LBDNET. This exercise involves the laboratories of the region: Argentina (laboratory support), Brazil, Chile, Cuba, Mexico, Peru and Uruguay and the laboratory of the Autonomous University of Barcelona-Espana (Joan Francesc Barquinero and staff). Finally, these countries will meet the next time for the drafting of a final report and later publication. (author)

  2. Bayesian Methods for Radiation Detection and Dosimetry

    CERN Document Server

    Groer, Peter G

    2002-01-01

    We performed work in three areas: radiation detection, external and internal radiation dosimetry. In radiation detection we developed Bayesian techniques to estimate the net activity of high and low activity radioactive samples. These techniques have the advantage that the remaining uncertainty about the net activity is described by probability densities. Graphs of the densities show the uncertainty in pictorial form. Figure 1 below demonstrates this point. We applied stochastic processes for a method to obtain Bayesian estimates of 222Rn-daughter products from observed counting rates. In external radiation dosimetry we studied and developed Bayesian methods to estimate radiation doses to an individual with radiation induced chromosome aberrations. We analyzed chromosome aberrations after exposure to gammas and neutrons and developed a method for dose-estimation after criticality accidents. The research in internal radiation dosimetry focused on parameter estimation for compartmental models from observed comp...

  3. New methodologies of biological dosimetry applied to human protection

    International Nuclear Information System (INIS)

    Catena, C.; Parasacchi, P.; Conti, D.; Righi, E.

    1995-04-01

    Biological dosimetry is a diagnostic methodology for the measurement of the individual dose absorbed in the case of accidental overexposition to ionizing radiation. It is demonstrated how in vitro radiobiological and chemobiological studies using cytogenetic methods (count of chromosomal aberrations and micronuclei) on human lymphocytes from healthy subjects and individuals undergoing radiotherapy or chemotherapy, as well as on lymphocytes of mammals other than man (comparative cytogenetics), can help to increase the basic radiobiological and chemobiological scientific information. Such information gives a valid contribution to understanding of the action of ionizing radiation or of pharmaceuticals on cells and, in return, can be of value to human radioprotection and chemoprotection. Cytogenetic studies can be summerized as follows: a) biodosimetry (estimate of dose received after accidental events); b) individual radiosensitivity (level of individual response); c) clinical radiobiology and chemobiology (individual response to radiopharmaceuticals, to radiotherapy and to chemopharmaceuticals); d) comparative radiobiology (cytogenetic studies on species other than man); e) animal model in the environmental surveillance

  4. Calibration Curves for Biological Dosimetry by Fluorescence In situ Hybridisation

    International Nuclear Information System (INIS)

    Stonati, L.; Durante, M.; Gensabella, G.; Gialanella, G.; Grossi, G.F.; Pugliese, M.; Scampoli, P.; Sgura, A.; Testa, A.; Tanzarella, C.

    2001-01-01

    Dose-response curves were measured for the induction of chromosomal aberrations in peripheral blood lymphocytes after acute exposure in vitro to 60 Co γ rays. Blood was obtained from four different healthy donors, and chromosomes were either observed at metaphase, following colcemid accumulation, or prematurely condensed by calyculin A. Cells were analysed in three different Italian laboratories. Chromosomes 1, 2, and 4 were painted, and simple-type interchanges between painted and non-painted chromosomes were scored in cells exposed in the dose range 0.1-3.0 Gy. The chemical-induced premature chromosome condensation method was also used combined with chromosome painting (chromosome 4 only) to determine calibration curves for high dose exposures (up to 20 Gy X rays). Calibration curves described in this paper will be used in our laboratories for biological dosimetry by fluorescence in situ hybridisation. (author)

  5. Developments in biological dosimetry for the nuclear industry

    Energy Technology Data Exchange (ETDEWEB)

    Gale, K L; Boreham, D R; Maves, S; Morrison, D P [Atomic Energy of Canada Ltd., Chalk River, ON (Canada)

    1996-12-31

    The purpose of this program is to develop methods for providing estimates of radiation exposure based on changes in the cells/tissues of exposed individuals. This work arises from the need for independent measures of exposure of workers when standard dose measurements are unavailable or questionable. The radiation-induced changes that we propose to measure have been correlated with carcinogenesis. It follows that the methods used should also provide indications of the likely biological consequences of radiation exposure for an individual. The consequences of radiation exposure lie in the resolution of the radiation effects at the cellular level. Accordingly, it is at the cellular level that our attention is directed. More precisely, since the consequences of most concern, cancer induction and the induction of inherited diseases, are the result of changes to the genetic material of cells (the DNA), it is the measurement of effects on DNA that are being investigated as possible dose meters. Individuals are unique in terms of their DNA and differ in their cellular capacities to repair the damage from an ionizing radiation dose. Because of these features, not only do biological dosimetry tools offer us a means of measuring a dose at the individual level but may also provide us with a measure of the ultimate risk associated with a given exposure. (author). 7 refs., 2 tabs., 4 figs.

  6. Developments in biological dosimetry for the nuclear industry

    International Nuclear Information System (INIS)

    Gale, K.L.; Boreham, D.R.; Maves, S.; Morrison, D.P.

    1995-01-01

    The purpose of this program is to develop methods for providing estimates of radiation exposure based on changes in the cells/tissues of exposed individuals. This work arises from the need for independent measures of exposure of workers when standard dose measurements are unavailable or questionable. The radiation-induced changes that we propose to measure have been correlated with carcinogenesis. It follows that the methods used should also provide indications of the likely biological consequences of radiation exposure for an individual. The consequences of radiation exposure lie in the resolution of the radiation effects at the cellular level. Accordingly, it is at the cellular level that our attention is directed. More precisely, since the consequences of most concern, cancer induction and the induction of inherited diseases, are the result of changes to the genetic material of cells (the DNA), it is the measurement of effects on DNA that are being investigated as possible dose meters. Individuals are unique in terms of their DNA and differ in their cellular capacities to repair the damage from an ionizing radiation dose. Because of these features, not only do biological dosimetry tools offer us a means of measuring a dose at the individual level but may also provide us with a measure of the ultimate risk associated with a given exposure. (author). 7 refs., 2 tabs., 4 figs

  7. Special methods used in neutron dosimetry

    International Nuclear Information System (INIS)

    Mas, P.

    1975-01-01

    The methods used in radiation reactor dosimetry which do not depend on fission reaction nor foil activation are reviewed. These other techniques are especially the following: the different types of self-powered detectors, with fast or slow response, their characteristics of noise and temperature effect, their practical uses: the damage detectors, considering the variations of their physical properties (resistivity, density, ...) and their use for characterizing the neutron spectra; the little loop with circulating fluids (air, nitrogen, helium, water) [fr

  8. Bayesian Methods for Radiation Detection and Dosimetry

    International Nuclear Information System (INIS)

    Peter G. Groer

    2002-01-01

    We performed work in three areas: radiation detection, external and internal radiation dosimetry. In radiation detection we developed Bayesian techniques to estimate the net activity of high and low activity radioactive samples. These techniques have the advantage that the remaining uncertainty about the net activity is described by probability densities. Graphs of the densities show the uncertainty in pictorial form. Figure 1 below demonstrates this point. We applied stochastic processes for a method to obtain Bayesian estimates of 222Rn-daughter products from observed counting rates. In external radiation dosimetry we studied and developed Bayesian methods to estimate radiation doses to an individual with radiation induced chromosome aberrations. We analyzed chromosome aberrations after exposure to gammas and neutrons and developed a method for dose-estimation after criticality accidents. The research in internal radiation dosimetry focused on parameter estimation for compartmental models from observed compartmental activities. From the estimated probability densities of the model parameters we were able to derive the densities for compartmental activities for a two compartment catenary model at different times. We also calculated the average activities and their standard deviation for a simple two compartment model

  9. Study on biological dosimetry of premature chromosome condensation technique

    International Nuclear Information System (INIS)

    Jiang Bo

    2005-01-01

    The premature chromosome condensation technique has been applied for biological dosimetry purpose. Premature chromo-some condensation was induced by incubating unstimulated human peripheral blood lymphocytes in the presence of okadaic acid or calyculin A (a phosphatase inhibitor) which eliminated the need for fusion with mitotic cells. It is now possible to examine the early damage induced by radiation. It is simple, exact when it combines with fluorecence in situ hybridization. (authors)

  10. Internal dosimetry hazard and risk assessments: methods and applications

    International Nuclear Information System (INIS)

    Roberts, G.A.

    2006-01-01

    Routine internal dose exposures are typically (in the UK nuclear industry) less than external dose exposures: however, the costs of internal dosimetry monitoring programmes can be significantly greater than those for external dosimetry. For this reason decisions on when to apply routine monitoring programmes, and the nature of these programmes, can be more critical than for external dosimetry programmes. This paper describes various methods for performing hazard and risk assessments which are being developed by RWE NUKEM Limited Approved Dosimetry Services to provide an indication when routine internal dosimetry monitoring should be considered. (author)

  11. Biological and clinical dosimetry, July 1, 1964 to December 31, 1984. Final report

    International Nuclear Information System (INIS)

    Laughlin, J.S.; Zeitz, L.

    1986-01-01

    The goal was to develop systems for the determination of absorbed dose in biological research and clinical applications. The primary method under study is the local absorbed dose calorimeter. In addition, secondary dosimetric systems such as ionization chambers, chemical dosimeters and thermoluminescent dosimeters (TLD) are being developed and applied to provide an absolute basis for the evaluation and comparison of experiments, treatments and other procedures using radiation. In keeping with these objectives this project has accomplished significant advances in the following areas: (1) local absorbed dose calorimetry; (2) neutron dosimetry; (3) dosimetry of ultra-high intensity radiation sources; (4) solid state detector and germanium gamma camera program; (5) dosimetry for brachytherapy; and (6) ''non-isolated sensor'' calorimeters

  12. Dosimetry methods in boron neutron capture therapy

    Energy Technology Data Exchange (ETDEWEB)

    Gambarini, G.; Artuso, E.; Felisi, M.; Regazzoni, V.; Giove, D. [Universita degli Studi di Milano, Department of Physics, Via Festa del Patrono 7, 20122 Milano (Italy); Agosteo, S.; Barcaglioni, L. [Istituto Nazionale di Fisica Nucleare, Milano (Italy); Campi, F.; Garlati, L. [Politecnico di Milano, Energy Department, Piazza Leonardo Da Vinci 32, 20133 Milano (Italy); De Errico, F. [Universita degli Studi di Pisa, Department of Civil and Industrial Engineering, Lungamo Pacinotti 43, 56126 Pisa (Italy); Borroni, M.; Carrara, M. [Fondazione IRCCS Istituto Nazionale Tumori, Medical Physics Unit, Via Venezian 1, 20133 Milano (Italy); Burian, J.; Klupak, V.; Viererbl, L.; Marek, M. [Research Centre Rez, Department of Neutron Physics, 250-68 Husinec-Rez (Czech Republic)

    2014-08-15

    Dosimetry studies have been carried out at thermal and epithermal columns of Lvr-15 research reactor for investigating the spatial distribution of gamma dose, fast neutron dose and thermal neutron fluence. Two different dosimetry methods, both based on solid state detectors, have been studied and applied and the accuracy and consistency of the results have been inspected. One method is based on Fricke gel dosimeters that are dilute water solutions and have good tissue equivalence for neutrons and also for all the secondary radiations produced by neutron interactions in tissue or water phantoms. Fricke gel dosimeters give the possibility of separating the various dose contributions, i.e. the gamma dose, the fast neutron dose and the dose due to charged particles generated during thermal neutron reactions by isotopes having high cross section, like 10-B. From this last dose, thermal neutron fluence can be obtained by means of the kerma factor. The second method is based on thermoluminescence dosimeters. In particular, the developed method draw advantage from the different heights of the peaks of the glow curve of such phosphors when irradiated with photons or with thermal neutrons. The results show that satisfactory results can be obtained with simple methods, in spite of the complexity of the subject. However, the more suitable dosimeters and principally their utilization and analysis modalities are different for the various neutron beams, mainly depending on the relative intensities of the three components of the neutron field, in particular are different for thermal and epithermal columns. (Author)

  13. Dosimetry methods in boron neutron capture therapy

    International Nuclear Information System (INIS)

    Gambarini, G.; Artuso, E.; Felisi, M.; Regazzoni, V.; Giove, D.; Agosteo, S.; Barcaglioni, L.; Campi, F.; Garlati, L.; De Errico, F.; Borroni, M.; Carrara, M.; Burian, J.; Klupak, V.; Viererbl, L.; Marek, M.

    2014-08-01

    Dosimetry studies have been carried out at thermal and epithermal columns of Lvr-15 research reactor for investigating the spatial distribution of gamma dose, fast neutron dose and thermal neutron fluence. Two different dosimetry methods, both based on solid state detectors, have been studied and applied and the accuracy and consistency of the results have been inspected. One method is based on Fricke gel dosimeters that are dilute water solutions and have good tissue equivalence for neutrons and also for all the secondary radiations produced by neutron interactions in tissue or water phantoms. Fricke gel dosimeters give the possibility of separating the various dose contributions, i.e. the gamma dose, the fast neutron dose and the dose due to charged particles generated during thermal neutron reactions by isotopes having high cross section, like 10-B. From this last dose, thermal neutron fluence can be obtained by means of the kerma factor. The second method is based on thermoluminescence dosimeters. In particular, the developed method draw advantage from the different heights of the peaks of the glow curve of such phosphors when irradiated with photons or with thermal neutrons. The results show that satisfactory results can be obtained with simple methods, in spite of the complexity of the subject. However, the more suitable dosimeters and principally their utilization and analysis modalities are different for the various neutron beams, mainly depending on the relative intensities of the three components of the neutron field, in particular are different for thermal and epithermal columns. (Author)

  14. Direct biological dosimetry in Chernobyl clear-up workers

    International Nuclear Information System (INIS)

    Maznik, N.A.; Vinnikov, V.A.; Rozdil'ski, S.I.

    1999-01-01

    Full text: In cases of large-scale radiological accidents like Chernobyl (1986) the estimation of somatic risk to exposed populations became a problem due to lack of direct physical dosimetry data. In such conditions the necessarily information can be obtained from biological dosimetry, firstly by chromosomal aberrations analysis in human peripheral blood lymphocytes. Conventional cytogenetic assay have been carried out in 130 persons recruited as clean-up workers ('liquidators') to the Chernobyl zone in 1986-87 yrs. Blood sampling was performed during 1 year post-irradiation, in 100 persons p to 0.5 year. The aberrations of choice for biological dosimetry were unstable chromosome exchanges (dicentrics and centric rings with accompanying acentric fragments). The dose calculations have been done using the linear term of the dose-response curve built with acute gamma-irradiation of blood in dose range up to 1 Gy. The distributions of biological doses were investigated in groups of liquidators with doses in documents ranging 17-140, 175-230, 250, 260-365, 440-1030 mSv and in the group of non-monitored persons. The weak correlation between monitored individual doses and biological doses was shown; the biological and physical dose distribution peculiarity in monitored groups is discussed. The distribution of individual aberration frequencies and the average yield of chromosomal exchanges in monitored and non-monitored liquidators were identical. The common cohort analysis (monitored and non-monitored persons) showed that the individual aberration yields distribution among liquidators was strictly randomised in accordance with Poissonian statistics. The cytogenetic dose estimations obtained can be of great value for somatic effects risk assessment in post-Chernobyl cohorts

  15. Biological Dosimetry Methods Employed at the Boris Kidric Institute of Nuclear Sciences; Application de Quelques Methodes Particulieres de Dosimetrie Biologique a l'Institut des Sciences Nucleaires Boris Kidric

    Energy Technology Data Exchange (ETDEWEB)

    Aleksic, B.; Veljkovic, D.; Djordjevic, O.; Djukic, Z. [Institut des Sciences Nucleaires Boris Kidric, Belgrade, Yugoslavia (Serbia)

    1971-06-15

    In addition to the more usual methods, the following methods are used at the Boris Kidric Institute of Nuclear Sciences in the medical supervision of occupationally exposed staff: analysis of bi nucleated lymphocytes and chromosome aberrations; physical examination (for example, determination of the pain sensitivity threshold, adaptation to pain, discrimination of sensitivity); capillaroscopy. These methods are described briefly and their practical application discussed. (author) [French] Outre les methodes habituelles, on a utilise a l'Institut Boris Kidric, pour le controle medical des travailleurs professionnellement exposes, des methodes d'analyse des lymphocytes binuclees et des aberrations chromosomiques, ainsi que des methodes d'examen physique telles que la determination du seuil de sensibilite douloureuse, de l'adaptation a la douleur et de la discrimination de la sensibilite, et la capillaroscopie. Ces methodes sont brievement decrites et leurs applications pratiques discutees. (author)

  16. Internal Dosimetry Intake Estimation using Bayesian Methods

    International Nuclear Information System (INIS)

    Miller, G.; Inkret, W.C.; Martz, H.F.

    1999-01-01

    New methods for the inverse problem of internal dosimetry are proposed based on evaluating expectations of the Bayesian posterior probability distribution of intake amounts, given bioassay measurements. These expectation integrals are normally of very high dimension and hence impractical to use. However, the expectations can be algebraically transformed into a sum of terms representing different numbers of intakes, with a Poisson distribution of the number of intakes. This sum often rapidly converges, when the average number of intakes for a population is small. A simplified algorithm using data unfolding is described (UF code). (author)

  17. Biological dosimetry: chromosomal aberration analysis for dose assessment

    International Nuclear Information System (INIS)

    1986-01-01

    In view of the growing importance of chromosomal aberration analysis as a biological dosimeter, the present report provides a concise summary of the scientific background of the subject and a comprehensive source of information at the technical level. After a review of the basic principles of radiation dosimetry and radiation biology basic information on the biology of lymphocytes, the structure of chromosomes and the classification of chromosomal aberrations are presented. This is followed by a presentation of techniques for collecting blood, storing, transporting, culturing, making chromosomal preparations and scaring of aberrations. The physical and statistical parameters involved in dose assessment are discussed and examples of actual dose assessments taken from the scientific literature are given

  18. Activities developed by the biological dosimetry laboratory of the Autoridad Regulatoria Nuclear - ARN of Argentina

    International Nuclear Information System (INIS)

    Radl, A.; Sapienza, C.E.; Taja, M.R.; Bubniak, R.; Deminge, M.; Di Giorgio, M.

    2013-01-01

    Biological dosimetry (DB) allows to estimate doses absorbed in individuals exposed to ionizing radiation through the quantification of stable and unstable chromosome aberrations (SCA and UCA). The frequency of these aberrations is referred to a calibration dose response curve (in vitro) to determine the doses of the individual to the whole body. The DB is a necessary support for programs of national radiation protection and response systems in nuclear or radiological emergencies in the event of accidental or incidental, single overexposure or large scale. In this context the Laboratory of Dosimetry Biological (LDB) of the Authority Regulatory Nuclear (ARN) Argentina develops and applies different dosimeters cytogenetic from four decades ago. These dosimeters provide a fact more within the whole of the information necessary for an accidental, complementing the physical and clinical dosimetry exposure assessment. The most widely used in the DB biodosimetric method is the quantification of SCA (dicentrics and rings Central) from a sample of venous blood. The LDB is accredited for the trial, under rules IRAM 301: 2005 (ISO / IEC 17025: 2005) and ISO 19238:2004. Test applies to the immediate dosimetry evaluation of acute exposures, all or a large part of the body in the range 0,1-5 Gy. In this context the LDB is part of the Latin American network of DB (LBDNet), BioDoseNet-who and response system in radiological emergencies and nuclear IAEA-RANET, being enabled to summon the LBDNet if necessary

  19. Review of unfolding methods for neutron flux dosimetry

    International Nuclear Information System (INIS)

    Stallmann, F.W.; Kam, F.B.K.

    1975-01-01

    The primary method in reactor dosimetry is the foil activation technique. To translate the activation measurements into neutron fluxes, a special data processing technique called unfolding is needed. Some general observations about the problems and the reliability of this approach to reactor dosimetry are presented. Current unfolding methods are reviewed. 12 references. (auth)

  20. Application of numerical analysis methods to thermoluminescence dosimetry

    International Nuclear Information System (INIS)

    Gomez Ros, J. M.; Delgado, A.

    1989-01-01

    This report presents the application of numerical methods to thermoluminescence dosimetry (TLD), showing the advantages obtained over conventional evaluation systems. Different configurations of the analysis method are presented to operate in specific dosimetric applications of TLD, such as environmental monitoring and mailed dosimetry systems for quality assurance in radiotherapy facilities. (Author) 10 refs

  1. Accidental and retrospective dosimetry using TL method

    International Nuclear Information System (INIS)

    Mesterházy, D.; Osvay, M.; Kovács, A.; Kelemen, A.

    2012-01-01

    Retrospective dosimetry is one of the most important tools of accidental dosimetry for dose estimation when dose measurement was not planned. In the affected area many objects can be applied as natural dosimeters. The paper discusses our recent investigations on various electronic components and common salt (NaCl) having useful thermoluminescence (TL) properties. Among materials investigated the electronic components of cell phones seem promising for retrospective dosimetry purposes, having high TL responses, proper glow curve peaks and the intensity of TL peaks vs. gamma dose received provided nearly linear response in the dose range of 10 mGy–1.5 Gy. - Highlights: ► Electronic components and common salt were investigated for accidental and retrospective dosimetry. ► SMD resistors seem promising for retrospective dosimetry purposes. ► Table salt can be used effectively for accidental dosimetry purposes, as well.

  2. Biological dosimetry study in differentiated thyroid carcinoma patients treated with 131Iodine

    International Nuclear Information System (INIS)

    Vallerga, Maria Belen

    2008-11-01

    Biological Dosimetry allows individual dose assessments based on the effect produced by ionizing radiation on a given biological parameter. The current biological endpoint being scored is chromosomal aberrations, relying on a lymphocytes culture from the patient's blood. The measured yield of chromosome aberrations is referred to a calibration curve obtaining the whole body dose. Different scenarios of overexposure can be taken into account by modifying the calculations leading to the dose estimate. Differentiated Thyroid Carcinoma patients undergo thyroidectomy followed by internal radiotherapy with 131 I. The treatment's success entails the delivery of a lethal dose to the tumour within the maximum tolerable dose to a critical organ (blood doses over 2 Gy could lead to bone marrow depression). Currently, there is no established agreement for the selection of radioiodine dosage. Historically, the empiric approach, based on clinical and biochemical data, has been recommended. Nevertheless, this method may not be associated with optimal outcomes. On the other hand, the dosimetric approach attempts to determine the maximum allowable activity to be administered, establishing its biokinetics by a diagnostic 131 I study. The methodology may be modified to further individualized treatment, however it requires validation. Biological dosimetry provides an independent measure of radiotherapy effect, as such it might aid in the validation process. Nonetheless, biological dosimetry has traditionally been applied in cases of external and accidental overexposure to ionizing radiation. Accordingly, it is mandatory to assess its value in medical internal incorporations (main objective of the present study). The applied treatment strategy comprises whole body dose assessment by biological and internal dosimetry in order to administer a personalized therapeutic activity. Overall, 20 patients with differentiated thyroid carcinoma were included in the study. For biological dosimetry

  3. An improved in vitro micronucleus assay to biological dosimetry

    International Nuclear Information System (INIS)

    Ocampo, Ivette Z.; Okazaki, Kayo; Vieira, Daniel P.

    2013-01-01

    The biological dosimetry is widely used to estimate the absorbed dose in people occupationally or accidentally exposed to the radiation for a better medical treatment, minimizing the harmful effects. Many techniques and methods have been proposed to detect and quantify the radioinduced lesions in genetic material, among them, the micronucleus (MN) assay. In the present study, we proposed an improved in vitro micronucleus technique that is rapid, sensitive and with minor cell manipulations. Assays were carried out with human tumor cells (MCF-7) seeded (3x10 4 cells) in slides placed into Petri dishes. Adherent cells were maintained with RPMI medium, supplemented with fetal calf serum, 1 % antibiotics, cytochalasin B (2 μg/mL), and incubated at 37 deg C in the presence of 5% CO2 for 72h. Cells were pre-treated for 24h with aminoguanidine, a nitric oxide synthase inhibitor. Nitric oxide is an intracellular free-radical, involved in DNA double-strand break repair mechanisms. After incubation, adherent cells on slides were briefly fixed with paraformaldehyde and stained with acridine orange (100 μg/mL) for analysis through fluorescence microscopy. Dye fluorescence permitted accurate discrimination between nuclei and micronuclei (bright green) and cytoplasm (red), and made possible a faster counting of binucleated cells. Aminoguanidine (2 mM) induced significant increase (p< 0.05) in frequencies of binucleated cells with micronuclei and in the number of micronuclei per binucleated cell. Data showed that proposed modifications permit to understand an early aspect of NO inhibition and suggested an improved protocol to MN assays. (author)

  4. Dosimetry using environmental and biological materials. Final report

    International Nuclear Information System (INIS)

    Haskell, E.; Kenner, G.; Hayes, R.

    1998-02-01

    This report summarizes a five year effort to improve the sensitivity and reliability of retrospective dosimetry methods, to collaborate with laboratories engaged in related research and to share the technology with startup laboratories seeking similar capabilities. This research program has focused on validation of electron paramagnetic resonance (EPR) as a dosimetry tool and on optimization of the technique by reducing the lower limits of detection, simplifying the process of sample preparation and analysis and speeding analysis to allow greater throughput in routine measurement situations. The authors have investigated the dosimetric signal of hard tissues in enamel, deorganified dentin, synthetic carbonated apatites and synthetic hydroxyapatite. This research has resulted in a total of 27 manuscripts which have been published, are in press, or have been submitted for publication. Of these manuscripts, 14 are included in this report and were indexed separately for inclusion in the data base

  5. Neutron dosimetry - A review

    Energy Technology Data Exchange (ETDEWEB)

    Baum, J W

    1955-03-29

    This review summarizes information on the following subjects: (1) physical processes of importance in neutron dosimetry; (2) biological effects of neutrons; (3) neutron sources; and (4) instruments and methods used in neutron dosimetry. Also, possible improvements in dosimetry instrumentation are outlined and discussed. (author)

  6. Main activities of the Latin American Network of Biological Dosimetry (LBDNet)

    International Nuclear Information System (INIS)

    Di Giorgio, M.; Vallerga, M.B.; Radl, A.; Taja, M.R.; Stuck Oliveira, M.; Valdivia, P.; Garcia Lima, O.; Lamadrid, A.; Gonzalez Mesa, J.E.; Romero Aguilera, I.; Mandina Cardoso, T.; Guerrero Carbajal, C.; Arceo Maldonado, C.; Espinoza, M.; Martinez Lopez, W.; Di Tomasso, M.; Barquinero, F.; Roy, L.

    2010-01-01

    The Latin American Biological Dosimetry Network (LBDNET) was constituted in 2007 for mutual assistance in case of a radiation emergency in the region supported by IAEA Technical Cooperation Projects RLA/9/054 and RLA/9/061. The main objectives are: a) to strengthen the technical capacities of Biological Dosimetry Services belonging to laboratories existing in the region (Argentine, Brazil, Chile, Cuba, Mexico, Peru and Uruguay) integrated in National Radiological Emergency Plans to provide a rapid biodosimetric response in a coordinated manner between countries and with RANET-IAEA/BioDoseNet-WHO, b) to provide support to other countries in the region lacking Biological Dosimetry laboratories, c) to consolidate the organization of the Latin American Biological Dosimetry Network for mutual assistance. The activities developed include technical meetings for protocols and chromosomal aberration scoring criteria unification, blood samples cultures exercises, chromosomal aberrations analysis at microscope, discussion of statistical methods and specialized software for dose calculation, the intercomparison between laboratory data after the analysis of slides with irradiated material and the intercomparison of the analysis of captured images distributed electronically in the WEB. The last exercise was the transportation of an irradiated human blood sample to countries inside and outside of the region. At the moment the exercises are concluded and they are pending to be published in reference journals. Results obtained show the capacity in the region for a biodosimetric response to a radiological accident. In the future the network will integrate techniques for high dose exposure evaluation and will enhance the interaction with other emergency systems in the region. (authors) [es

  7. Biological dosimetry in cases gives occupational high exposition to ionizing radiations

    International Nuclear Information System (INIS)

    Ramalho, Adriana T.; Costa, Maria Lucia P.; Oliveira, Monica S.; Silva, Francisco Cesar A.

    1998-01-01

    From 1983 the cytogenetics dosimetry method it has been used as routine in the IRD laboratory in the period 1983 at 1997 but a high exposition occupational case the physical dosimeters happened in Brazil they were investigated through the cytogenetics dosimetry technique. This technique is employ when the dosimetry personal marks a high dose to 100 mSv (0,1 Gy) that is the cut-off minimum detected in the dosimetry cytogenetics

  8. Development of radiation biological dosimetry and treatment of radiation-induced damaged tissue

    International Nuclear Information System (INIS)

    Cho, Chul Koo; Kim, Tae Hwan; Lee, Yun Sil

    2000-04-01

    Util now, only a few methods have been developed for radiation biological dosimetry such as conventional chromosome aberration and micronucleus in peripheral blood cell. However, because these methods not only can be estimated by the expert, but also have a little limitation due to need high technique and many times in the case of radiation accident, it is very difficult to evaluate the absorbed dose of victims. Therefore, we should develop effective, easy, simple and rapid biodosimetry and its guideline(triage) to be able to be treated the victims as fast as possible. We established the apoptotic fragment assay, PCC, comet assay, and micronucleus assay which was the significant relationship between dose and cell damages to evaluate the irradiated dose as correct and rapid as possible using lymphocytes and crypt cells, and compared with chromosome dosimetry and micronucleus assay

  9. Development of radiation biological dosimetry and treatment of radiation-induced damaged tissue

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Chul Koo; Kim, Tae Hwan; Lee, Yun Sil [and others

    2000-04-01

    Util now, only a few methods have been developed for radiation biological dosimetry such as conventional chromosome aberration and micronucleus in peripheral blood cell. However, because these methods not only can be estimated by the expert, but also have a little limitation due to need high technique and many times in the case of radiation accident, it is very difficult to evaluate the absorbed dose of victims. Therefore, we should develop effective, easy, simple and rapid biodosimetry and its guideline(triage) to be able to be treated the victims as fast as possible. We established the apoptotic fragment assay, PCC, comet assay, and micronucleus assay which was the significant relationship between dose and cell damages to evaluate the irradiated dose as correct and rapid as possible using lymphocytes and crypt cells, and compared with chromosome dosimetry and micronucleus assay.

  10. RENEB - Running the European Network of biological dosimetry and physical retrospective dosimetry.

    Science.gov (United States)

    Kulka, Ulrike; Abend, Michael; Ainsbury, Elizabeth; Badie, Christophe; Barquinero, Joan Francesc; Barrios, Lleonard; Beinke, Christina; Bortolin, Emanuela; Cucu, Alexandra; De Amicis, Andrea; Domínguez, Inmaculada; Fattibene, Paola; Frøvig, Anne Marie; Gregoire, Eric; Guogyte, Kamile; Hadjidekova, Valeria; Jaworska, Alicja; Kriehuber, Ralf; Lindholm, Carita; Lloyd, David; Lumniczky, Katalin; Lyng, Fiona; Meschini, Roberta; Mörtl, Simone; Della Monaca, Sara; Monteiro Gil, Octávia; Montoro, Alegria; Moquet, Jayne; Moreno, Mercedes; Oestreicher, Ursula; Palitti, Fabrizio; Pantelias, Gabriel; Patrono, Clarice; Piqueret-Stephan, Laure; Port, Matthias; Prieto, María Jesus; Quintens, Roel; Ricoul, Michelle; Romm, Horst; Roy, Laurence; Sáfrány, Géza; Sabatier, Laure; Sebastià, Natividad; Sommer, Sylwester; Terzoudi, Georgia; Testa, Antonella; Thierens, Hubert; Turai, Istvan; Trompier, François; Valente, Marco; Vaz, Pedro; Voisin, Philippe; Vral, Anne; Woda, Clemens; Zafiropoulos, Demetre; Wojcik, Andrzej

    2017-01-01

    A European network was initiated in 2012 by 23 partners from 16 European countries with the aim to significantly increase individualized dose reconstruction in case of large-scale radiological emergency scenarios. The network was built on three complementary pillars: (1) an operational basis with seven biological and physical dosimetric assays in ready-to-use mode, (2) a basis for education, training and quality assurance, and (3) a basis for further network development regarding new techniques and members. Techniques for individual dose estimation based on biological samples and/or inert personalized devices as mobile phones or smart phones were optimized to support rapid categorization of many potential victims according to the received dose to the blood or personal devices. Communication and cross-border collaboration were also standardized. To assure long-term sustainability of the network, cooperation with national and international emergency preparedness organizations was initiated and links to radiation protection and research platforms have been developed. A legal framework, based on a Memorandum of Understanding, was established and signed by 27 organizations by the end of 2015. RENEB is a European Network of biological and physical-retrospective dosimetry, with the capacity and capability to perform large-scale rapid individualized dose estimation. Specialized to handle large numbers of samples, RENEB is able to contribute to radiological emergency preparedness and wider large-scale research projects.

  11. Non-invasive biological dosimetry of the skin

    International Nuclear Information System (INIS)

    Barton, S.; Marks, R.; Charles, M.W.; Wells, J.

    1986-01-01

    Investigations designed to identify a potential biological dosimetry technique to examine the effects of X-ray doses down to 0.1 Gy on human skin, are described. In a variety of parameters assessed, the most important changes observed were a significant depression in epidermal cell production in the basal layer after X-ray doses between 0.5 Gy and 1 Gy and a concomitant reduction in the desquamation rate of corneocytes after doses above 1 Gy. Changes in non-specific esterase (NSE) activity were also observed. Further work is described which applies these results to several non-invasive techniques which may have potential for routine application. Preliminary data from irradiated human skin are presented on the measurement of forced desquamation, the evaluation of NSE activity from hair samples and the evaluation of stratum corneum turnover time using the fluorescent dye, dansyl chloride. (author)

  12. Biological dosimetry for mixed gamma-neutron field

    International Nuclear Information System (INIS)

    Brandao, J.O.C.; Santos, J.A.L.; Souza, P.L.G.; Lima, F.F.; Vilela, E.C.; Calixto, M.S.; Santos, N.

    2011-01-01

    There is increasing concern about airline crew members (about one million worldwide) exposed to measurable neutrons doses. Historically, cytogenetic biodosimetry assays have been based on quantifying asymmetrical chromosome alterations (dicentrics, centric rings and acentric fragments) in mitogen-stimulated T-lymphocytes in their first mitosis after radiation exposure. Increased levels of chromosome damage in peripheral blood lymphocytes are a sensitive indicator of radiation exposure and they are routinely exploited for assessing radiation absorbed dose after accidental or occupational exposure. Since radiological accidents are not common, not all nations feel that it is economically justified to maintain biodosimetry competence. However, dependable access to biological dosimetry capabilities is completely critical in event of an accident. In this paper the dose-response curve was measured for the induction of chromosomal alterations in peripheral blood lymphocytes after chronic exposure in vitro to mixed gamma-neutron field. Blood was obtained from one healthy donor and exposed to two mixed gamma-neutron field from sources 241 AmBe (20 Ci) at the Neutron Calibration Laboratory (NCL - CRCN/NE - PE - Brazil). The evaluated absorbed doses were 0.2 Gy; 1.0 Gy and 2.5 Gy. The dicentric chromosomes were observed at metaphase, following colcemide accumulation and 1000 well-spread metaphases were analyzed for the presence of dicentrics by two experts after painted by giemsa 5%. The preliminary results showed a linear dependence between radiations absorbed dose and dicentric chromosomes frequencies. Dose-response curve described in this paper will contribute to the construction of calibration curve that will be used in our laboratory for biological dosimetry. (author)

  13. Biological dosimetry in case of combined radiation injuries. Biologicheskaya dozimetriya pri kombinirovannykh radiatsionnykh porazheniyakh

    Energy Technology Data Exchange (ETDEWEB)

    Vladimirov, V G; Teslenko, V M

    1990-11-01

    The state of biological dosimetry methods and prospects for their development are considered. Attention is paid to biological indicators of radiation injuries caused by nuclear weapons. It is noted, that determination of the number of lymphocytes in the blood in case of combined radiation injuries should be concerned with great care and in each case the analysis results should reffered to critically and supported by the data from other investigations. Promissing are the methods related to dermination of reticulocyte number in the peripheral blood within the irradiation dose range, causing bone marrow form of radiation syndrome, method of leukocyte adhesion and some other methods based on the change of biophysical caracteristics of cell membranes. To increase the information efficiency it is necessary to combine these methods with the methods, based on genetic change registration, and to develop a combined method.

  14. A new method for dosimetry with films radiochromic

    International Nuclear Information System (INIS)

    Mendez Carot, I.

    2013-01-01

    in this paper a new method is presented and the results of the comparison between the calibration is summarized based on a planning reference and calibration obtained from the irradiated fragments measure different dose levels multichannel compare dosimetry based on the weighted average dosimetry described by Micke et al.(present in the FilmQAPro software) and, finally, show different results obtained with the method proposed in several applications clinics. (Author)

  15. Development of technology for biological dosimetry -A study on the radiation and environmental safety-

    International Nuclear Information System (INIS)

    Lee, Kang Suk; Cheon, Ki Jeong; Kim, Kook Chan; Kim, Jin Kyu; Kim, Sang Bok; Kim, In Kyu; Park, Hyo Kook

    1994-07-01

    α-amylase showed a significant increase in its activity when exposed to radiation of 0.1 Gy. However it had no relationship with radiation dose. Enzyme activities in liver tissue showed similar changes to those in serum. Among others, changes in acid phosphatase activity were highly related to radiation dose. Of acute phase proteins in serum, CRP, ceruloplasmin and haptoglobin positively responded to radiation while albumin did negatively. ELISA proved to be an efficient method to detect changes in serum protein level. Finally the measurements of changes in APRs using ELISA could provide an useful tools for biological dosimetry. (Author)

  16. Dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Hurst, G S; Ritchie, R H; Sanders, F W; Reinhardt, P W; Auxier, J A; Wagner, E B; Callihan, A D; Morgan, K Z [Health Physics Division, Oak Ridge National Laboratory, Oak Ridge, TN (United States)

    1962-03-15

    The methods of dosimetry used for investigation of the doses received by the individuals exposed in the Yugoslav accident were essentially those used in connection with the Oak Ridge Y-12 accident. An outline of the general scheme is as follows: When fast neutrons enter the human body, most of these are moderated to thermal energy and a small fraction of these are captured by a (n, gamma) process in Na sup 2 sup 3 , giving rise to Na sup 2 sup 4 , which by virtue of its emission of high-energy gamma rays with a half life of 14.8 h, is easily detected. It has been shown that the probability of capture, making Na sup 2 sup 4 , is not a strong function of the energy of the fast neutrons and that the probability of capture for neutrons is higher in the fast region than in the thermal region. Thus, the uniform distribution of Na sup 2 sup 3 in the human body provides an excellent means of normalizing the neutron exposure of an individual. in particular, for a given neutron energy spectrum the fast neutron dose is proportional to the ratio Na sup 2 sup 4 /Na sup 2 sup 3 in the body or in the blood system. This method of normalization is quite important in the dosimetry of radiation accidents since no assumptions need be made about the exact location of an individual at the time of the energy release. The importance of this fact can be made clear by reference to the Y-12 accident where it was shown by calculation of the neutron dose based on the known number of fissions and the stated location of the individual that one of the surviving individuals would have received a dose several times the lethal value. To accomplish the measurements described, the zero power R sub B reactor was operated in two ranges of power level, 'low' power and 'high 'power. Neutron leakage spectrum was obtained by multigroup approximation of the Boltzmann transport equation. Prompt gamma rays from fission products, from capture in the moderator and fuel cladding as well as in tank walls are given

  17. Dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Hurst, G S; Ritchie, R H; Sanders, F W; Reinhardt, P W; Auxier, J A; Wagner, E B; Callihan, A D; Morgan, K Z [Health Physics Division, Oak Ridge National Laboratory, Oak Ridge, TN (United States)

    1962-03-01

    The methods of dosimetry used for investigation of the doses received by the individuals exposed in the Yugoslav accident were essentially those used in connection with the Oak Ridge Y-12 accident. An outline of the general scheme is as follows: When fast neutrons enter the human body, most of these are moderated to thermal energy and a small fraction of these are captured by a (n, {gamma}) process in Na{sup 23}, giving rise to Na{sup 24}, which by virtue of its emission of high-energy gamma rays with a half life of 14.8 h, is easily detected. It has been shown that the probability of capture, making Na{sup 24}, is not a strong function of the energy of the fast neutrons and that the probability of capture for neutrons is higher in the fast region than in the thermal region. Thus, the uniform distribution of Na{sup 23} in the human body provides an excellent means of normalizing the neutron exposure of an individual. in particular, for a given neutron energy spectrum the fast neutron dose is proportional to the ratio Na{sup 24}/Na{sup 23} in the body or in the blood system. This method of normalization is quite important in the dosimetry of radiation accidents since no assumptions need be made about the exact location of an individual at the time of the energy release. The importance of this fact can be made clear by reference to the Y-12 accident where it was shown by calculation of the neutron dose based on the known number of fissions and the stated location of the individual that one of the surviving individuals would have received a dose several times the lethal value. To accomplish the measurements described, the zero power R{sub B} reactor was operated in two ranges of power level, 'low' power and 'high 'power. Neutron leakage spectrum was obtained by multigroup approximation of the Boltzman transport equation. Prompt gamma rays from fission products, from capture in the moderator and fuel cladding as well as in tank walls are given. A summary of the 4{pi

  18. A method for neutron dosimetry in ultrahigh flux environments

    International Nuclear Information System (INIS)

    Ougouag, A.M.; Wemple, C.A.; Rogers, J.W.

    1996-01-01

    A method for neutron dosimetry in ultrahigh flux environments is developed, and devices embodying it are proposed and simulated using a Monte Carlo code. The new approach no longer assumes a linear relationship between the fluence and the activity of the nuclides formed by irradiation. It accounts for depletion of the original ''foil'' material and for decay and depletion of the formed nuclides. In facilities where very high fluences are possible, the fluences inferred by activity measurements may be ambiguous. A method for resolving these ambiguities is also proposed and simulated. The new method and proposed devices should make possible the use of materials not traditionally considered desirable for neutron activation dosimetry

  19. Solid State and Chemical Radiation Dosimetry in Medicine and Biology. Proceedings of a Symposium

    International Nuclear Information System (INIS)

    1967-01-01

    Proceedings of a Symposium organized by the IAEA and held in Vienna, 3-7 October 1966. The meeting was attended by 104 participants from 21 countries and three international organizations. Contents: Solid state dosimetry (17 papers); Chemical dosimetry (10 papers); Invited lectures (2 papers); General aspects and other methods of dosimetry (6 papers); Panel discussion on research and development needed in dosimetry. Each paper is in its original language (32 English, 2 French and 1 Spanish) and is preceded by an abstract in English and one in the original language, if this is not English. Discussions are in English. (author)

  20. Solid State and Chemical Radiation Dosimetry in Medicine and Biology. Proceedings of a Symposium

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1967-03-15

    Proceedings of a Symposium organized by the IAEA and held in Vienna, 3-7 October 1966. The meeting was attended by 104 participants from 21 countries and three international organizations. Contents: Solid state dosimetry (17 papers); Chemical dosimetry (10 papers); Invited lectures (2 papers); General aspects and other methods of dosimetry (6 papers); Panel discussion on research and development needed in dosimetry. Each paper is in its original language (32 English, 2 French and 1 Spanish) and is preceded by an abstract in English and one in the original language, if this is not English. Discussions are in English. (author)

  1. Overview of physical dosimetry methods for triage application integrated in the new European network RENEB.

    Science.gov (United States)

    Trompier, François; Burbidge, Christopher; Bassinet, Céline; Baumann, Marion; Bortolin, Emanuela; De Angelis, Cinzia; Eakins, Jonathan; Della Monaca, Sara; Fattibene, Paola; Quattrini, Maria Cristina; Tanner, Rick; Wieser, Albrecht; Woda, Clemens

    2017-01-01

    In the EC-funded project RENEB (Realizing the European Network in Biodosimetry), physical methods applied to fortuitous dosimetric materials are used to complement biological dosimetry, to increase dose assessment capacity for large-scale radiation/nuclear accidents. This paper describes the work performed to implement Optically Stimulated Luminescence (OSL) and Electron Paramagnetic Resonance (EPR) dosimetry techniques. OSL is applied to electronic components and EPR to touch-screen glass from mobile phones. To implement these new approaches, several blind tests and inter-laboratory comparisons (ILC) were organized for each assay. OSL systems have shown good performances. EPR systems also show good performance in controlled conditions, but ILC have also demonstrated that post-irradiation exposure to sunlight increases the complexity of the EPR signal analysis. Physically-based dosimetry techniques present high capacity, new possibilities for accident dosimetry, especially in the case of large-scale events. Some of the techniques applied can be considered as operational (e.g. OSL on Surface Mounting Devices [SMD]) and provide a large increase of measurement capacity for existing networks. Other techniques and devices currently undergoing validation or development in Europe could lead to considerable increases in the capacity of the RENEB accident dosimetry network.

  2. Calibration curves for biological dosimetry by drug-induced prematurely condensed chromosomes in human lymphocytes

    International Nuclear Information System (INIS)

    Kang, C. M.; Chung, H. C.; Cho, C. K.

    2002-01-01

    To develop the cytogenetic tool to detect chromosome damages after high dose exposure with 60 Coγ- rays, dose-response curves were measured for induction of prematurely condensed chromosomes (PCC) in peripheral lymphocytes. Blood was obtained from 10 different healthy donors, and given okadaic acid (OA) 500nM in cultured lymphocytes 1h after radiation exposure. Cells were analyzed by the frequencies of OA-induced PCC rings because it is difficult to obtain mitotic chromosomes using a conventional chromosome aberration (CA). PCC-rings were scored in cells exposed in the dose range of 0.2-16Gy. The frequency of the cells with PCC and the dose-response relationship for the yield of PCC rings were examined in the irradiated lymphocytes. The yield of PCC-rings increased with dose dependent-manner up to 16Gy. The observed dose-effect relationship for the percentage of cells with PCC-rings was calculated by linear-quadratic model. This technique can be applied to biological dosimetry of radiation exposures involving whole body irradiation to allow damaged chromosomes to be detected with great sensitivity. Detection of okadaic acid-induced PCC rings is a useful method up to 16Gy or more doses in estimating the absorbed doses of victims after high dose exposure. Calibration curves described in this paper will be used in our laboratory for biological dosimetry by PCC-ring after a high dose exposure

  3. Absolute measurements methods for proton beam dosimetry

    International Nuclear Information System (INIS)

    Laitano, R.F.

    1998-01-01

    A widespread interest in improving proton beam characteristics and related dosimetry became apparent in the recent years, even if the advantages of protons in radiotherapy were pointed out since 1946. The early treatments by proton beams were made for a long time on a small number of patients in very few accelerators sharing their use with nuclear-physics experiments. The first proton accelerator totally dedicated to radiotherapy was established just in 1990 at the Loma Linda Medical Center in the USA. A further reason of the slowly growing use of protons for therapy in the early years, was the lack of adequate means for accurate localization of the treatment volume. The potentialities of protons in imparting a largest part of their energy to very small volumes became exploitable only after the established clinical use of accurate imaging techniques such as based on CT, NMR, PET, etc

  4. Personnel dosimetry methods introduced in the Czechoslovak national laboratories

    International Nuclear Information System (INIS)

    Trousil, J.; Singer, J.; Kokta, L.; Prouza, Z.

    1979-01-01

    Personnel dosimetry methods are described that were developed in the Institute for Research, Production and Application of Radioisotopes and that have been or will be introduced in the national personnel dosimetry service. In Czechoslovakia, workers exposed to a radiation risk are divided into two groups, according to the level of the risk. The criterion is the possibility of exceeding one tenth of the MPD. For the higher risk group, a complex dose meter is usually used for dosimetry of photon and beta radiation; it contains a film dose meter and a radiothermoluminescent (RTL) glass dose meter. The RTL glass dose meter also serves as an accident dose meter. For neutron dosimetry, a dose meter comprising a solid-state track detector in combination with fissionable foils has been introduced. For accident dosimetry, a silicon diode of Czechoslovak production is used. For the lower risk group, only the introduction of an RTL dose meter is foreseen. There will be a three month control period; for neutron dosimetry, the track detector in combination with fissionable foils is retained. For measurements of hand doses, a themoluminescent ring dose meter has been introduced. The dose meters are described, giving information on the types of detectors employed, measurement techniques and descriptions of the basic characteristics of the instruments, their basic dosimetric parameters and the dose and energy ranges which can be measured. The results of international comparisons are presented; these have served to confirm the measurement precision. In conclusion, some questions of dose-meter calibration are summarized, and the problems of dose measurement in mixed fields of neutrons and gamma rays are discussed. (author)

  5. Recombination methods for boron neutron capture therapy dosimetry

    International Nuclear Information System (INIS)

    Golnik, N.; Tulik, P.; Zielczynski, M.

    2003-01-01

    The radiation effects of boron neutron capture therapy (BNCT) are associated with four-dose-compartment radiation field - boron dose (from 10 B(n,α) 7 Li) reaction), proton dose from 14 N(n,p) 14 C reaction, neutron dose (mainly fast and epithermal neutrons) and gamma-ray dose (external and from capture reaction 1 H(n,γ) 2 D). Because of this the relation between the absorbed dose and the biological effects is very complex and all the above mentioned absorbed dose components should be determined. From this point of view, the recombination chambers can be very useful instruments for characterization of the BNCT beams. They can be used for determination of gamma and high-LET dose components for the characterization of radiation quality of mixed radiation fields by recombination microdosimetric method (RMM). In present work, a graphite high-pressure recombination chamber filled with nitrogen, 10 BF 3 and tissue equivalent gas was used for studies on application of RMM for BNCT dosimetry. The use of these gases or their mixtures opens a possibility to design a recombination chamber for determination of the dose fractions due to gamma radiation, fast neutrons, neutron capture on nitrogen and high LET particles from (n, 10 B) reaction in simulated tissue with different content of 10 B. (author)

  6. Decomposition of spectra in EPR dosimetry using the matrix method

    International Nuclear Information System (INIS)

    Sholom, S.V.; Chumak, V.V.

    2003-01-01

    The matrix method of EPR spectra decomposition is developed and adapted for routine application in retrospective EPR dosimetry with teeth. According to this method, the initial EPR spectra are decomposed (using methods of matrix algebra) into several reference components (reference matrices) that are specific for each material. Proposed procedure has been tested on the example of tooth enamel. Reference spectra were a spectrum of an empty sample tube and three standard signals of enamel (two at g=2.0045, both for the native signal and one at g perpendicular =2.0018, g parallel =1.9973 for the dosimetric signal). Values of dosimetric signals obtained using the given method have been compared with data obtained by manual manipulation of spectra, and good coincidence was observed. This allows considering the proposed method as potent for application in routine EPR dosimetry

  7. Biological in vivo dosimetry with an external measuring technique under application of a labelled DNA-precursor (iodine-125-desoxyuridine)

    International Nuclear Information System (INIS)

    Porschen, W.; Zamboglou, N.; Muehlensiepen, H.; Feinendegen, L.E.

    1976-01-01

    The depression of the incorporation rate of IDU in the whole body or in the bone marrow is a sensitive indicator for a whole-body irradiation. It was found that the maximum effect is observed some 4 hours after irradiation. For this reason, bone marrow cells were labelled in vitro with IDU 4 hours after whole-body irradiation. This method proved to be extraordinarily sensitive and resulted in reproducible effects which occurred already at doses below 5 rad. All the other biological methods of dosimetry known so far are less sensitive. Although the theory explaining these results is not yet fully clarified, this method of dosimetry appears to offer practical possibilities of application. (orig.) [de

  8. Selective saturation method for EPR dosimetry with tooth enamel

    International Nuclear Information System (INIS)

    Ignatiev, E.A.; Romanyukha, A.A.; Koshta, A.A.; Wieser, A.

    1996-01-01

    The method of selective saturation is based on the difference in the microwave (mw) power dependence of the background and radiation induced EPR components of the tooth enamel spectrum. The subtraction of the EPR spectrum recorded at low mw power from that recorded at higher mw power provides a considerable reduction of the background component in the spectrum. The resolution of the EPR spectrum could be improved 10-fold, however simultaneously the signal-to-noise ratio was found to be reduced twice. A detailed comparative study of reference samples with known absorbed doses was performed to demonstrate the advantage of the method. The application of the selective saturation method for EPR dosimetry with tooth enamel reduced the lower limit of EPR dosimetry to about 100 mGy. (author)

  9. Internal sources dosimetry

    International Nuclear Information System (INIS)

    Savio, Eduardo

    1994-01-01

    The absorbed dose, need of estimation in risk evaluation in the application of radiopharmaceuticals in Nuclear Medicine practice,internal dosimetry,internal and external sources. Calculation methodology,Marinelli model,MIRD system for absorbed dose calculation based on biological parameters of radiopharmaceutical in human body or individual,energy of emitted radiations by administered radionuclide, fraction of emitted energy that is absorbed by target body.Limitation of the MIRD calculation model. A explanation of Marinelli method of dosimetry calculation,β dosimetry. Y dosimetry, effective dose, calculation in organs and tissues, examples. Bibliography .

  10. Biological dosimetry of patients with differenced carcinoma of thyroid treated with Iodine-131

    International Nuclear Information System (INIS)

    Vallerga, M. B.; Rojo, A.M.; Taja, M.R.; Deluca, G.; Di Giorgio, M.; Fadel, A.; Cabrejas, M.; Valdivieso, C.

    2006-01-01

    aberrations it was considered absorbed dose to whole body. The obtained doses were compared by the different biological methods used. The evaluation by internal dosimetry of the data obtained tracer post-activity allowed to personalize the activity of I-131 to administer, starting from physical-mathematical models that consider the particular biokinetics of each patient (MIRD methodology). The doses estimated by the used biological dosemeters were consistent among them. It was discussed its scopes and limitations to be applied in the validation of the dosimetric estimation based on models, in order to administer a therapeutic dose protecting the patient of the adverse effects of the internal radiotherapy in organs that are not target of the same one. The acquired experience is considered of utility to give answer in cases of radioiodine incorporation in occupationally exposed personnel. (Author)

  11. Canadian Cytogenetic Emergency network (CEN) for biological dosimetry following radiological/nuclear accidents.

    Science.gov (United States)

    Miller, Susan M; Ferrarotto, Catherine L; Vlahovich, Slavica; Wilkins, Ruth C; Boreham, Douglas R; Dolling, Jo-Anna

    2007-07-01

    To test the ability of the cytogenetic emergency network (CEN) of laboratories, currently under development across Canada, to provide rapid biological dosimetry using the dicentric assay for triage assessment, that could be implemented in the event of a large-scale radiation/nuclear emergency. A workshop was held in May 2004 in Toronto, Canada, to introduce the concept of CEN and recruit clinical cytogenetic laboratories at hospitals across the country. Slides were prepared for dicentric assay analysis following in vitro irradiation of blood to a range of gamma-ray doses. A minimum of 50 metaphases per slide were analyzed by 41 people at 22 different laboratories to estimate the exposure level. Dose estimates were calculated based on a dose response curve generated at Health Canada. There were a total of 104 dose estimates and 96 (92.3%) of them fell within the expected range using triage scoring criteria. Half of the laboratories analyzed 50 metaphases in biological dosimetry. When this network is fully operational, it will be the first of its kind in Canada able to respond to radiological/nuclear emergencies by providing triage quality biological dosimetry for a large number of samples. This network represents an alternate expansion of existing international emergency biological dosimetry cytogenetic networks.

  12. Biological dosimetry in radiological protection: dose response curves elaboration for 60Co and 137Cs

    International Nuclear Information System (INIS)

    Silva, Marcia Augusta da

    1997-01-01

    Ionizing radiation sources for pacific uses are being extensively utilized by modern society and the applications of these sources have raised the probability of the occurrence of accidents. The accidental exposition to radiation creates a necessity of the development of methods to evaluate dose quantity. This data could be obtained by the measurement of damage caused by radiation in the exposed person. The radiation dose can be estimated in exposed persons through physical methods (physical dosimetry) but the biological methods can't be dispensed, and among them, the cytogenetic one that makes use of chromosome aberrations (dicentric and centric ring) formed in peripheral blood lymphocytes (PBL) exposed to ionizing radiation. This method correlates the frequency of radioinduced aberrations with the estimated absorbed dose, as in vitro as in vivo, which is called cytogenetic dosimetry. By the introduction of improved new techniques in culture, in the interpretation of aberrations in the different analysers of slides and by the adoption of different statistical programs to analyse the data, significant differences are observed among laboratories in dose-response curves (calibration curves). The estimation of absorbed dose utilizing other laboratory calibration curves may introduce some uncertainties, so the International Atomic Energy Agency (IAEA) advises that each laboratory elaborates your own dose-response curve for cytogenetic dosimetry. The results were obtained from peripheral blood lymphocytes of the healthy and no-smoking donors exposed to 60 Co and 137 Cs radiation, with dose rate of 5 cGy.min. -1 . Six points of dose were determined 20,50,100,200,300,400 cGy and the control not irradiated. The analysed aberrations were of chromosomic type, dicentric and centric ring. The dose response curve for dicentrics were obtained by frequencies weighted in liner-quadratic mathematic model and the equation resulted were for 60 Co: Y = (3 46 +- 2.14)10 -4 cGy -1 + (3

  13. Development of radiological emergency preparedness and biological dosimetry technology

    Energy Technology Data Exchange (ETDEWEB)

    Han, Moon Hee; Kim, In Gyoo; Kim, Kook Chan; Kim, Eun Han; Suh, Kyung Suk; Hwang, Won Tae; Choi, Young Gil; Shim, Hae Won; Lee, Jeong Ho; Lee, Kang Suk

    1999-04-01

    Large-scale field tracer experiments have been conducted on Ulchin and Wolsung nuclear sites for the purpose of validating FADAS and of analyzing the environmental characteristics around the nuclear site. The most influential factor in atmospheric dispersion is the meteorological condition. During the experiment, meteorological data were measured on the release point and the selected positions among sampling points. Once radioactive materials are released to the atmosphere, members of public may be exposed through the environmental media such as air, soil and foods. Therefore, to protect the public, adequate countermeasures should be taken at due time for those exposure pathways. Both processes of justification and optimization are applied to a countermeasure simultaneously for decision-making. The work scope of biological research for the radiation protection had contained the search of biological microanalytic methods for the assessment of health effect by radiation and toxic agents, the standardization of human t-lymphocyte cell culture and polymerase chain reaction, T-cell clonal assay, and the quantification of mutation frequency in hypoxanthine (guanine) phosphoribosyl transferase (hprt) gene locus by single exposure or combined exposure. Especially, the polymerase chain reaction methods by usage of reverse transcriptase had been developed to analyze of gene product by {gamma} - radiation and chemical (pentachlorophenol) agent exposure, and investigate the point mutation in hprt gene locus of T-lymphocytes. (author)

  14. Development of radiological emergency preparedness and biological dosimetry technology

    International Nuclear Information System (INIS)

    Han, Moon Hee; Kim, In Gyoo; Kim, Kook Chan; Kim, Eun Han; Suh, Kyung Suk; Hwang, Won Tae; Choi, Young Gil; Shim, Hae Won; Lee, Jeong Ho; Lee, Kang Suk

    1999-04-01

    Large-scale field tracer experiments have been conducted on Ulchin and Wolsung nuclear sites for the purpose of validating FADAS and of analyzing the environmental characteristics around the nuclear site. The most influential factor in atmospheric dispersion is the meteorological condition. During the experiment, meteorological data were measured on the release point and the selected positions among sampling points. Once radioactive materials are released to the atmosphere, members of public may be exposed through the environmental media such as air, soil and foods. Therefore, to protect the public, adequate countermeasures should be taken at due time for those exposure pathways. Both processes of justification and optimization are applied to a countermeasure simultaneously for decision-making. The work scope of biological research for the radiation protection had contained the search of biological microanalytic methods for the assessment of health effect by radiation and toxic agents, the standardization of human t-lymphocyte cell culture and polymerase chain reaction, T-cell clonal assay, and the quantification of mutation frequency in hypoxanthine (guanine) phosphoribosyl transferase (hprt) gene locus by single exposure or combined exposure. Especially, the polymerase chain reaction methods by usage of reverse transcriptase had been developed to analyze of gene product by γ - radiation and chemical (pentachlorophenol) agent exposure, and investigate the point mutation in hprt gene locus of T-lymphocytes. (author)

  15. Overview of dosimetry methods used in medical exposure

    International Nuclear Information System (INIS)

    Ninsiima, Lynn

    2016-04-01

    Medical exposure is the highest means of contribution of ionizing radiation to humans. The different modalities in medical exposure present a high risk to the human body as a result of the dose associated with them. However, with the knowledge of the available dosimetry techniques, medical exposure can be highly beneficial to the patients involved. This project provides an overview of the available dosimetry methods in all the medical exposure modalities and the dosimetric quantities required in order to estimate the dose received by the patients in a bid to keep it as low as reasonably achievable yet with the required diagnostic image quality and treatment being availed. With the knowledge about the dosimetric techniques, required qualification and appropriate training of the workers in the medical field together with the principles of justification and optimization of the procedures, both the medical practitioners and the patients are able to achieve the required goal, diagnosis and treatment at the end of the day. (au)

  16. Dosimetry using radiosensitive gels in radiotherapy: significance and methods

    International Nuclear Information System (INIS)

    Gibon, D.; Bourel, P.; Castelain, B.; Marchandise, X.; Rousseau, J.

    2001-01-01

    The goal of conformal radiotherapy is to concentrate the dose in a well-defined volume by avoiding the neighbouring healthy structures. This technique requires powerful treatment planning software and a rigorous control of estimated dosimetry. The usual dosimetric tools are not adapted to visualize and validate complex 3D treatment. Dosimetry by radiosensitive gel permits visualization and measurement of the three-dimensional dose distribution. The objective of this work is to report on current work in this field and, based on our results and our experience, to draw prospects for an optimal use of this technique. Further developments will relate to the realization of new radiosensitive gels satisfying, as well as possible, cost requirements, easy realization and use, magnetic resonance imagery (MRI) sensitivity, tissue equivalence, and stability. Other developments focus on scanning methods, especially in MRI to measure T1 and T2. (author)

  17. Stochastic Methods in Biology

    CERN Document Server

    Kallianpur, Gopinath; Hida, Takeyuki

    1987-01-01

    The use of probabilistic methods in the biological sciences has been so well established by now that mathematical biology is regarded by many as a distinct dis­ cipline with its own repertoire of techniques. The purpose of the Workshop on sto­ chastic methods in biology held at Nagoya University during the week of July 8-12, 1985, was to enable biologists and probabilists from Japan and the U. S. to discuss the latest developments in their respective fields and to exchange ideas on the ap­ plicability of the more recent developments in stochastic process theory to problems in biology. Eighteen papers were presented at the Workshop and have been grouped under the following headings: I. Population genetics (five papers) II. Measure valued diffusion processes related to population genetics (three papers) III. Neurophysiology (two papers) IV. Fluctuation in living cells (two papers) V. Mathematical methods related to other problems in biology, epidemiology, population dynamics, etc. (six papers) An important f...

  18. Biological dosimetry studies for boron neutron capture therapy at the RA-1 research reactor facility

    International Nuclear Information System (INIS)

    Trivillin, Veronica A.; Heber, Elisa M.; Itoiz, Maria E.; Schwint, Amanda E.; Castillo, Jorge

    2004-01-01

    Initial physical dosimetry measurements have been completed using activation spectrometry and thermoluminescent dosimeters to characterize the BNCT facility developed at the RA-1 research reactor operated by the National Atomic Energy Commission in Buenos Aires. Biological dosimetry was performed employing the hamster cheek pouch oral cancer model previously validated for BNCT studies by our group. Results indicate that the RA-1 neutron source produces useful dose rates for BNCT studies but that some improvements in the initial configuration will be needed to optimize the spectrum for thermal-neutron BNCT research applications. (author)

  19. Biological dosimetry by the triage dicentric chromosome assay - Further validation of international networking

    Energy Technology Data Exchange (ETDEWEB)

    Wilkins, Ruth C., E-mail: Ruth.Wilkins@hc-sc.gc.ca [Health Canada, Ottawa, ON K1A 0K9 (Canada); Romm, Horst; Oestreicher, Ursula [Bundesamt fur Strahlenschutz, 38226 Salzgitter (Germany); Marro, Leonora [Health Canada, Ottawa, ON K1A 0K9 (Canada); Yoshida, Mitsuaki A. [Biological Dosimetry Section, Dept. of Dose Assessment, Research Center for Radiation Emergency Medicine, NIRS, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555 (Japan); Department Radiation Biology, Institute of Radiation Emergency Medicine, Hirosaki University Graduate School of Health Sciences, 66-1 Hon-cho, Hirosaki, Aomori 036-8564 (Japan); Suto, Y. [Biological Dosimetry Section, Dept. of Dose Assessment, Research Center for Radiation Emergency Medicine, NIRS, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555 (Japan); Prasanna, Pataje G.S. [National Cancer Institute, Division of Cancer Treatment and Diagnosis, Radiation Research Program, 6130 Executive Blvd., MSC 7440, Bethesda, MD 20892-7440 (United States)

    2011-09-15

    Biological dosimetry is an essential tool for estimating radiation doses received to personnel when physical dosimetry is not available or inadequate. The current preferred biodosimetry method is based on the measurement of radiation-specific dicentric chromosomes in exposed individuals' peripheral blood lymphocytes. However, this method is labor-, time- and expertise-demanding. Consequently, for mass casualty applications, strategies have been developed to increase its throughput. One such strategy is to develop validated cytogenetic biodosimetry laboratory networks, both national and international. In a previous study, the dicentric chromosome assay (DCA) was validated in our cytogenetic biodosimetry network involving five geographically dispersed laboratories. A complementary strategy to further enhance the throughput of the DCA among inter-laboratory networks is to use a triage DCA where dose assessments are made by truncating the labor-demanding and time-consuming metaphase spread analysis to 20 - 50 metaphase spreads instead of routine 500 - 1000 metaphase spread analysis. Our laboratory network also validated this triage DCA, however, these dose estimates were made using calibration curves generated in each laboratory from the blood samples irradiated in a single laboratory. In an emergency situation, dose estimates made using pre-existing calibration curves which may vary according to radiation type and dose rate and therefore influence the assessed dose. Here, we analyze the effect of using a pre-existing calibration curve on assessed dose among our network laboratories. The dose estimates were made by analyzing 1000 metaphase spreads as well as triage quality scoring and compared to actual physical doses applied to the samples for validation. The dose estimates in the laboratory partners were in good agreement with the applied physical doses and determined to be adequate for guidance in the treatment of acute radiation syndrome.

  20. Biological dosimetry, scopes and limitations; Dosimetria biologica, alcances y limitaciones

    Energy Technology Data Exchange (ETDEWEB)

    Guerrero C, C.; Brena V, M. [Departamento de Biologia, Instituto Nacional de Investigaciones Nucleares, C.P. 52045 Salazar, Estado de Mexico (Mexico)

    1999-07-01

    The analysis of the aberrations in chromosomes is an alternative to establish the exposure dose to the radiation, when the information provided by the traditional physical methods is insufficient. There are diverse causes by which it can reached to apply an alternative system, such is the case of exposures of another persons to the management of radiation sources, which not carry physical dosemeter. Contrary case is to the occupational exposure personnel (OEP), what must to utilize some system for determining the exposure dose, even so can be needed the case for more information. In any case, the cells from the affected person are the alternative without the biological system be overlap to the physical, it is complementary. (Author)

  1. Latin-American Biological Dosimetry Network (LBDNET) Intercomparison Exercise. Evaluation through triage and conventional scoring criteria. Development of a new approach for statistical data analysis

    International Nuclear Information System (INIS)

    Di Giorgio, M.; Vallerga, M.B.; Radl, A.

    2011-01-01

    Biological Dosimetry is a necessary support for National Radiation Protection Programs and Emergency Response Schemes. A Latin-American Biological Dosimetry Network (LBDNET) has been constituted by the biological dosimetry laboratories from: Argentina, Brazil, Chile, Cuba, Mexico, Peru, and Uruguay (IAEA Regional Project RLA9/054, 2007). The biological dosimetry laboratory of Argentina organized an international biological dosimetry intercomparison for the analysis of some relevant parameters involved in dose assessment, to reinforce the response capability in accidental situations requiring the activation of mutual assistance mechanisms and thus, constituting the bases of the LBDNET organization. (authors)

  2. Dosimetry Methods for Human Exposure to Non-Ionising Radiation

    International Nuclear Information System (INIS)

    Poljak, D.; Sarolic, A.; Doric, V.; Peratta, C.; Peratta, A.

    2011-01-01

    The paper deals with human exposure to electromagnetic fields from extremely low frequencies (ELF) to GSM frequencies. The problem requires (1) the assessment of external field generated by electromagnetic interference (EMI) source at a given frequency (incident field dosimetry) and then (2) the assessment of corresponding fields induced inside the human body (internal field dosimetry). Several methods used in theoretical and experimental dosimetry are discussed within this work. Theoretical dosimetry models at low frequencies are based on quasistatic approaches, while analyses at higher frequencies use the full-wave models. Experimental techniques involve near and far field measurement. Human exposure to power lines, transformer substations, power line communication (PLC) systems, Radio Frequency Identification (RFID) antennas and GSM base station antenna systems is analyzed. The results o are compared to the exposure limits proposed by relevant safety guidelines. Theoretical incident dosimetry used in this paper is based on the set of Pocklington integro-differential equations for the calculation of the current distribution and subsequently radiated field from power lines. Experimental incident dosimetry techniques involve measurement techniques of fields radiated by RFID antennas and GSM base station antennas. First example set of numerical results is related to the internal dosimetry of realistic well-grounded body model exposed to vertical component of the electric field E = 10 kV/m generated by high voltage power line. The results obtained via the HNA model exceed the ICNIRP basic restrictions for public exposure (2 mA/m 2 ) in knee (8.6 mA/m 2 ) and neck (9.8 mA/m 2 ) and for occupational exposure (10 mA/m 2 ) in ankle (32 mA/m 2 ). In the case of a conceptual model of a realistic human body inside a transformer substation room touching a control panel at the potential φ0 = 400 V and with two scenarios for dry-air between worker's hand and panel, the values

  3. Methods of dosimetry for aquatic organisms

    International Nuclear Information System (INIS)

    Woodhead, D.S.

    1979-01-01

    The importance is emphasized of accurate estimates of radiation doses or dose rates that must be made for experiments to investigate the effects of irradiation on aquatic organisms. Computational methods are described which provide the best estimate of radiation dose or dose rates received by aquatic organisms when living in contaminated water. Also, techniques appropriate to the determination of radiation doses from external sources are briefly discussed. (author)

  4. Preliminary study on biological dosimetry using alkaline single cell gel electrophoresis of human peripheral lymphocytes

    International Nuclear Information System (INIS)

    Liu Qingjie; Lu Xue; Feng Jiangbing; Chen Deqing; Chen Xiaosui

    2006-01-01

    Objective: To explore the feasibility of alkaline single cell gel electrophoresis (SCGE) in biological dosimetry of ionizing radiation. Methods: Normal peripheral blood samples from two healthy males were exposed to different doses coblat-60 gamma-rays, ranged from 0 to 5 Gy, and the tail length (TL) and Oliver tail moment (TM) of the lymphocytes were analyzed with SCGE. The dose-effect curves of TL and TM were fitted respectively. The TL and TM of lymphocytes for eight radiation workers were analyzed with SCGE, cumulative doses were estimated using the fitted TL and TM equations, and then compared with the recorded monitoring doses. Results: The TLs or TMs of normal human lymphocytes were increased with the irradiation doses, and its relationship can be fitted with a linear-quadratic equations: Y=13.59 + 20.87X - 2.27 X 2 for TL, and Y = 8.50 + 15.04X - 1.43X 2 for TM, respectively (Y denotes TL or TM value, X is radiation dose). The doses estimated with TM equation were closer to the recorded monitoring doses than that with TL equation. Conclusions: The TM in lymphocytes analyzed with SCGE is a promising radiation biological dosimeter. (authors)

  5. Biological dosimetry of ionizing radiation: Evaluation of the dose with cytogenetic methodologies by the construction of calibration curves

    Science.gov (United States)

    Zafiropoulos, Demetre; Facco, E.; Sarchiapone, Lucia

    2016-09-01

    In case of a radiation accident, it is well known that in the absence of physical dosimetry biological dosimetry based on cytogenetic methods is a unique tool to estimate individual absorbed dose. Moreover, even when physical dosimetry indicates an overexposure, scoring chromosome aberrations (dicentrics and rings) in human peripheral blood lymphocytes (PBLs) at metaphase is presently the most widely used method to confirm dose assessment. The analysis of dicentrics and rings in PBLs after Giemsa staining of metaphase cells is considered the most valid assay for radiation injury. This work shows that applying the fluorescence in situ hybridization (FISH) technique, using telomeric/centromeric peptide nucleic acid (PNA) probes in metaphase chromosomes for radiation dosimetry, could become a fast scoring, reliable and precise method for biological dosimetry after accidental radiation exposures. In both in vitro methods described above, lymphocyte stimulation is needed, and this limits the application in radiation emergency medicine where speed is considered to be a high priority. Using premature chromosome condensation (PCC), irradiated human PBLs (non-stimulated) were fused with mitotic CHO cells, and the yield of excess PCC fragments in Giemsa stained cells was scored. To score dicentrics and rings under PCC conditions, the necessary centromere and telomere detection of the chromosomes was obtained using FISH and specific PNA probes. Of course, a prerequisite for dose assessment in all cases is a dose-effect calibration curve. This work illustrates the various methods used; dose response calibration curves, with 95% confidence limits used to estimate dose uncertainties, have been constructed for conventional metaphase analysis and FISH. We also compare the dose-response curve constructed after scoring of dicentrics and rings using PCC combined with FISH and PNA probes. Also reported are dose response curves showing scored dicentrics and rings per cell, combining

  6. Dose estimation by biological methods

    International Nuclear Information System (INIS)

    Guerrero C, C.; David C, L.; Serment G, J.; Brena V, M.

    1997-01-01

    The human being is exposed to strong artificial radiation sources, mainly of two forms: the first is referred to the occupationally exposed personnel (POE) and the second, to the persons that require radiological treatment. A third form less common is by accidents. In all these conditions it is very important to estimate the absorbed dose. The classical biological dosimetry is based in the dicentric analysis. The present work is part of researches to the process to validate the In situ Fluorescent hybridation (FISH) technique which allows to analyse the aberrations on the chromosomes. (Author)

  7. Dosimetry methods for fuels, cladding and structural materials

    International Nuclear Information System (INIS)

    Roettger, H.

    1980-01-01

    This volume of the proceedings of the symposium on reactor dosimetry covers the following topics: the metallurgy and dosimetry interface, radiation damage correlations of structural materials and damage analyses techniques, dosimetry for fusion materials, light water reactor pressure vessel surveillance in practice and irradiation experiments, fast reactor and reseach reactor characterization

  8. The use of the dicentric assay for biological dosimetry for radiation accidents in Bulgaria.

    Science.gov (United States)

    Hadjidekova, Valeria; Hristova, Rositsa; Ainsbury, Elizabeth A; Atanasova, Petya; Popova, Ljubomira; Staynova, Albena

    2010-02-01

    This paper details the construction of a 137Cs gamma calibration curve that has been established for dicentric assay and the testing and validation of the curve through biological dosimetry in three situations of suspected workplace overexposure that arose accidentally or through negligence or lack of appropriate safety measures. The three situations were: (1) suspected 137Cs contamination in a factory air supply; (2) suspected exposure to an industrial 192Ir source; and (3) accidental exposure of construction workers to radiation from a 60Co radiotherapy source in a hospital medical physics department. From a total of 24 potentially-exposed subjects, only one worker was found to have a statistically significant dose (0.16 Gy, 95% confidence intervals 0.02-0.43 Gy). In all other cases, the main function of the biological dosimetry was to reassure the subjects that any dose received was low.

  9. Radiation protection - Performance criteria for service laboratories performing biological dosimetry by cytogenetics

    International Nuclear Information System (INIS)

    2004-01-01

    This International Standard provides criteria for quality assurance and quality control, evaluation of the performance and the accreditation of biological dosimetry by cytogenetic service laboratories. This International Standard addresses: a) the confidentiality of personal information, for the customer and the service laboratory, b) the laboratory safety requirements, c) the calibration sources and calibration dose ranges useful for establishing the reference dose-effect curves allowing the dose estimation from chromosome aberration frequency, and the minimum detection levels, d) the scoring procedure for unstable chromosome aberrations used for biological dosimetry, e) the criteria for converting a measured aberration frequency into an estimate of absorbed dose, f) the reporting of results, g) the quality assurance and quality control, h) informative annexes containing examples of a questionnaire, instructions for customers, a data sheet for recording aberrations and a sample report

  10. Mammalian spermatogenesis as a new system for biologic dosimetry of ionizing irradiation

    International Nuclear Information System (INIS)

    Hacker, U.; Schumann, J.; Goehde, W.

    1982-01-01

    The radiation induced reduction of the number of DNA synthesizing cells (spermatogonia) is described using the fast-working flow cytophotometer. Since there is no shoulder in the initial part of the dose response curve this model of biologic dosimetry is very sensitive. The D 50 value is 0.25 Gy; a radiation exposure of only 0.1 Gy can be detected. (Auth.)

  11. The Latin American Biological Dosimetry Network (LBDNet): Argentina, Brazil, Chile, Cuba, Mexico, Peru, Uruguay

    Energy Technology Data Exchange (ETDEWEB)

    Guerrero C, C.; Arceo M, C. [ININ, Carretera Mexico-Toluca s/n, Ocoyoacac 52750, Estado de Mexico (Mexico); Di Giorgio, M.; Vallerga, M.; Radl, A. [Autoridad Regulatoria Nuclear, Av. del Libertador 8250, C1429 BNP CABA (Argentina); Taja, M.; Seoane, A.; De Luca, J. [Universidad Nacionald de La Plata, Av. 7 No. 1776, La Plata 1900, Buenos Aires (Argentina); Stuck O, M. [Instituto de Radioproteccion y Dosimetria, Av. Salvador Allende s/n, Recreio dos Bandeirantes, Rio de Janeiro (Brazil); Valdivia, P., E-mail: lbdnet@googlegroups.co [Comision Chilena de Energia, Amutanegui 95, Santiago Centro, Santiago (Chile)

    2010-10-15

    Biological dosimetry is a necessary support for national radiation protection programs and emergency response schemes. The Latin American Biological Dosimetry Network (LBDNet) was formally founded in 2007 for mutual assistance in case of radiation emergencies and for providing support to other Latin American countries that do not have bio dosimetry laboratories. In the frame of the IAEA Technical Cooperation Projects RLA/9/54 and RLA/9/61 the following activities have been performed: a) An international intercomparison exercise organized during 2007-2008 included six European countries and LBDNet laboratories. Relevant parameters related with dose assessment were evaluated through triage and conventional scoring criteria. A new approach for statistical data analysis was developed including assessment of inter-laboratory reproducibility and intra-laboratory repeatability. Overall, the laboratory performance was satisfactory for mutual cooperation purposes. b) In 2009, LBDNet and two European countries carried out a digital image intercomparison exercise involving dose assessment from metaphase images distributed electronically through internet. The main objectives were to evaluate scoring feasibility on metaphase images and time response. In addition a re-examination phase was considered in which the most controversial images were discussed jointly, this allowed for the development of a homogeneous scoring criteria within the network. c) A further exercise was performed during 2009 involving the shipment of biological samples for biological dosimetry assessment. The aim of this exercise was to test the timely and properly sending and receiving blood samples under national and international regulations. A total of 14 laboratories participated in this joint IAEA, PAHO and WHO. (Author)

  12. The Latin American Biological Dosimetry Network (LBDNet): Argentina, Brazil, Chile, Cuba, Mexico, Peru, Uruguay

    International Nuclear Information System (INIS)

    Guerrero C, C.; Arceo M, C.; Di Giorgio, M.; Vallerga, M.; Radl, A.; Taja, M.; Seoane, A.; De Luca, J.; Stuck O, M.; Valdivia, P.

    2010-10-01

    Biological dosimetry is a necessary support for national radiation protection programs and emergency response schemes. The Latin American Biological Dosimetry Network (LBDNet) was formally founded in 2007 for mutual assistance in case of radiation emergencies and for providing support to other Latin American countries that do not have bio dosimetry laboratories. In the frame of the IAEA Technical Cooperation Projects RLA/9/54 and RLA/9/61 the following activities have been performed: a) An international intercomparison exercise organized during 2007-2008 included six European countries and LBDNet laboratories. Relevant parameters related with dose assessment were evaluated through triage and conventional scoring criteria. A new approach for statistical data analysis was developed including assessment of inter-laboratory reproducibility and intra-laboratory repeatability. Overall, the laboratory performance was satisfactory for mutual cooperation purposes. b) In 2009, LBDNet and two European countries carried out a digital image intercomparison exercise involving dose assessment from metaphase images distributed electronically through internet. The main objectives were to evaluate scoring feasibility on metaphase images and time response. In addition a re-examination phase was considered in which the most controversial images were discussed jointly, this allowed for the development of a homogeneous scoring criteria within the network. c) A further exercise was performed during 2009 involving the shipment of biological samples for biological dosimetry assessment. The aim of this exercise was to test the timely and properly sending and receiving blood samples under national and international regulations. A total of 14 laboratories participated in this joint IAEA, PAHO and WHO. (Author)

  13. Mammalian spermatogenesis as a new system for biologic dosimetry of ionizing irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Hacker, U; Schumann, J; Goehde, W [Muenster Univ. (Germany, F.R.). Radiologische Klinik

    1982-01-01

    The radiation induced reduction of the number of DNA synthesizing cells (spermatogonia) is described using the fast-working flow cytophotometer. Since there is no shoulder in the initial part of the dose response curve this model of biologic dosimetry is very sensitive. The D/sub 50/ value is 0.25 Gy; a radiation exposure of only 0.1 Gy can be detected.

  14. Validation of internal dosimetry protocols based on stochastic method

    International Nuclear Information System (INIS)

    Mendes, Bruno M.; Fonseca, Telma C.F.; Almeida, Iassudara G.; Trindade, Bruno M.; Campos, Tarcisio P.R.

    2015-01-01

    Computational phantoms adapted to Monte Carlo codes have been applied successfully in radiation dosimetry fields. NRI research group has been developing Internal Dosimetry Protocols - IDPs, addressing distinct methodologies, software and computational human-simulators, to perform internal dosimetry, especially for new radiopharmaceuticals. Validation of the IDPs is critical to ensure the reliability of the simulations results. Inter comparisons of data from literature with those produced by our IDPs is a suitable method for validation. The aim of this study was to validate the IDPs following such inter comparison procedure. The Golem phantom has been reconfigured to run on MCNP5. The specific absorbed fractions (SAF) for photon at 30, 100 and 1000 keV energies were simulated based on the IDPs and compared with reference values (RV) published by Zankl and Petoussi-Henss, 1998. The SAF average differences from RV and those obtained in IDP simulations was 2.3 %. The SAF largest differences were found in situations involving low energy photons at 30 keV. The Adrenals and thyroid, i.e. the lowest mass organs, had the highest SAF discrepancies towards RV as 7.2 % and 3.8 %, respectively. The statistic differences of SAF applying our IDPs from reference values were considered acceptable at the 30, 100 and 1000 keV spectra. We believe that the main reason for the discrepancies in IDPs run, found in lower masses organs, was due to our source definition methodology. Improvements of source spatial distribution in the voxels may provide outputs more consistent with reference values for lower masses organs. (author)

  15. Validation of internal dosimetry protocols based on stochastic method

    Energy Technology Data Exchange (ETDEWEB)

    Mendes, Bruno M.; Fonseca, Telma C.F., E-mail: bmm@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Almeida, Iassudara G.; Trindade, Bruno M.; Campos, Tarcisio P.R., E-mail: tprcampos@yahoo.com.br [Universidade Federal de Minas Gerais (DEN/UFMG), Belo Horizonte, MG (Brazil). Departamento de Engenharia Nuclear

    2015-07-01

    Computational phantoms adapted to Monte Carlo codes have been applied successfully in radiation dosimetry fields. NRI research group has been developing Internal Dosimetry Protocols - IDPs, addressing distinct methodologies, software and computational human-simulators, to perform internal dosimetry, especially for new radiopharmaceuticals. Validation of the IDPs is critical to ensure the reliability of the simulations results. Inter comparisons of data from literature with those produced by our IDPs is a suitable method for validation. The aim of this study was to validate the IDPs following such inter comparison procedure. The Golem phantom has been reconfigured to run on MCNP5. The specific absorbed fractions (SAF) for photon at 30, 100 and 1000 keV energies were simulated based on the IDPs and compared with reference values (RV) published by Zankl and Petoussi-Henss, 1998. The SAF average differences from RV and those obtained in IDP simulations was 2.3 %. The SAF largest differences were found in situations involving low energy photons at 30 keV. The Adrenals and thyroid, i.e. the lowest mass organs, had the highest SAF discrepancies towards RV as 7.2 % and 3.8 %, respectively. The statistic differences of SAF applying our IDPs from reference values were considered acceptable at the 30, 100 and 1000 keV spectra. We believe that the main reason for the discrepancies in IDPs run, found in lower masses organs, was due to our source definition methodology. Improvements of source spatial distribution in the voxels may provide outputs more consistent with reference values for lower masses organs. (author)

  16. Towards Establishing Capacity for Biological Dosimetry at Ghana Atomic Energy Commission.

    Science.gov (United States)

    Achel, Daniel Gyingiri; Achoribo, Elom; Agbenyegah, Sandra; Adaboro, Rudolph M; Donkor, Shadrack; Adu-Bobi, Nana A K; Agyekum, Akwasi A; Akuamoa, Felicia; Tagoe, Samuel N; Kyei, Kofi A; Yarney, Joel; Serafin, Antonio; Akudugu, John M

    2016-01-01

    The aim of this study was not only to obtain basic technical prerequisites for the establishment of capacity of biological dosimetry at the Ghana Atomic Energy Commission (GAEC) but also to stimulate interest in biological dosimetry research in Ghana and Sub-Saharan Africa. Peripheral blood from four healthy donors was exposed to different doses (0-6 Gy) of gamma rays from a radiotherapy machine and lymphocytes were subsequently stimulated, cultured, and processed according to standard protocols for 48-50 h. Processed cells were analyzed for the frequencies of dicentric and centric ring chromosomes. Radiation dose delivered to the experimental model was verified using GafChromic® EBT films in parallel experiments. Basic technical prerequisites for the establishment of capacity of biological dosimetry in the GAEC have been realized and expertise in the dicentric chromosome assay consolidated. We successfully obtained preliminary cytogenetic data for a dose-response relationship of the irradiated blood lymphocytes. The data strongly indicate the existence of significant linear (α) and quadratic (β) components and are consistent with those published for the production of chromosome aberrations in comparable absorbed dose ranges.

  17. A contribution to the study of the biological dosimetry in clinical radiopathology

    International Nuclear Information System (INIS)

    Eston, T.E. de.

    1983-01-01

    The effects of total body irradiation with different radiation doses from a 4MeV linear accelerator on organs and tissues of adult male rabbits were studied. Doses of 0.50, 2.00, 6.00 and 8.00 Gy were applied. Different organic parameters were evaluated before and after various periods of the post-irradiation time. Mortality did not occured for 0.50 or 2.00 Gy, but morbility was greater in comparison with the control; sexual potency was maintained. 'Impotentia colundi' occured with 6 Gy. A small loss of weight occured with 2.00 Gy and a higher loss for 6.00 Gy, with later recovery. Blood parameters varied even for lowest dose. Alterations were evident in the bone marrow activity for 2.00 and 6.00 Gy. Spermatides, spermatocytes and mature spermatozoids were affect even by low doses, the laters loosing motility. Significant difference was observed in the relation DNA/RNA for irradiated-and control animals. The results showed that T3 asssay could serve as 'biological indicator' of irradiation in a period of at least 7 hours and for doses of 4Gy or more. Using the kinetic method, an increase of glutamic oxalacetic transaminase (GOT) seric levels was observed for 6.00 Gy after 7 hours and a decrease for the glutamic pyruvic transaminase (GPT). Fasting glycemy and catecolamines urinary extraction were not statiscally significants. The study of chromosomal aberrations that occur in lymphocytes after 'in vitro' irradiation showed that this is at the present moment the most efficient method for biological dosimetry. (M.A.) [pt

  18. Biological Dosimetry of X-rays by micronuclei study; Dosimetria Biologica de rayos-X mediante el estudio de micronucleos

    Energy Technology Data Exchange (ETDEWEB)

    Gomez, E.; Silva, A.; Navlet, J.

    1991-07-01

    Biological dosimetry consists of estimating absorbed doses for people exposed to radiation by mean biological methods. Several indicators used are based in haematological, biochemical an cytogenetics data, although nowadays without doubt, the cytogenetic method is considered to be the most reliable, in this case, the study of micronuclei in peripheral blood lymphocytes citokinetics blocked can be related to absorbed dose through an experimental calibration curve. An experimental dose-response curve, using micronuclei assay for X-rays at 250 kVp, 43,79 rads/min and temperature 37 degree centigree has been produced. Experimental data is fitted to model Y=C+ {alpha}D+BD''2 where Y is the number of micronuclei per cell and D the dose. The curve is compared with those produced elsewhere. (Author) 24 refs.

  19. Biological Dosimetry of X-rays by micronuclei study; Dosimetria Biologica de rayos-X mediante el estudio de micronucleos

    Energy Technology Data Exchange (ETDEWEB)

    Gomez, E; Silva, A; Navlet, J

    1991-07-01

    Biological dosimetry consists of estimating absorbed doses for people exposed to radiation by mean biological methods. Several indicators used are based in haematological, biochemical an cytogenetics data, although nowadays without doubt, the cytogenetic method is considered to be the most reliable, in this case, the study of micronuclei in peripheral blood lymphocytes citokinetics blocked can be related to absorbed dose through an experimental calibration curve. An experimental dose-response curve, using micronuclei assay for X-rays at 250 kVp, 43,79 rads/min and temperature 37 degree centigree has been produced. Experimental data is fitted to model Y=C+ {alpha}D+BD''2 where Y is the number of micronuclei per cell and D the dose. The curve is compared with those produced elsewhere. (Author) 24 refs.

  20. General guidelines for safe and expeditious international transport of samples subjected to biological dosimetry assessment.

    Science.gov (United States)

    Di Giorgio, Marina; Radl, Analía; Taja, María R; Bubniak, Ruth; Deminge, Mayra; Sapienza, Carla; Vázquez, Marina; Baciu, Florian; Kenny, Pat

    2014-06-01

    It has been observed that victims of accidental overexposures show better chance of survival if they receive medical treatment early. The increased risk of scenarios involving mass casualties has stimulated the scientific community to develop tools that would help the medical doctors to treat victims. The biological dosimetry has become a routine test to estimate the dose, supplementing physical and clinical dosimetry. In case of radiation emergencies, in order to provide timely and effectively biological dosimetry assistance it is essential to guarantee an adequate transport of blood samples in principal, for providing support to countries that do not have biodosimetry laboratories. The objective of the present paper is to provide general guidelines, summarised in 10 points, for timely and proper receiving and sending of blood samples under National and International regulations, for safe and expeditious international transport. These guidelines cover the classification, packaging, marking, labelling, refrigeration and documentation requirements for the international shipping of blood samples and pellets, to provide assistance missions with a tool that would contribute with the preparedness for an effective biodosimetric response in cases of radiological or nuclear emergencies. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  1. A parameterization method and application in breast tomosynthesis dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Li, Xinhua; Zhang, Da; Liu, Bob [Division of Diagnostic Imaging Physics and Webster Center for Advanced Research and Education in Radiation, Department of Radiology, Massachusetts General Hospital, Boston, Massachusetts 02114 (United States)

    2013-09-15

    Purpose: To present a parameterization method based on singular value decomposition (SVD), and to provide analytical parameterization of the mean glandular dose (MGD) conversion factors from eight references for evaluating breast tomosynthesis dose in the Mammography Quality Standards Act (MQSA) protocol and in the UK, European, and IAEA dosimetry protocols.Methods: MGD conversion factor is usually listed in lookup tables for the factors such as beam quality, breast thickness, breast glandularity, and projection angle. The authors analyzed multiple sets of MGD conversion factors from the Hologic Selenia Dimensions quality control manual and seven previous papers. Each data set was parameterized using a one- to three-dimensional polynomial function of 2–16 terms. Variable substitution was used to improve accuracy. A least-squares fit was conducted using the SVD.Results: The differences between the originally tabulated MGD conversion factors and the results computed using the parameterization algorithms were (a) 0.08%–0.18% on average and 1.31% maximum for the Selenia Dimensions quality control manual, (b) 0.09%–0.66% on average and 2.97% maximum for the published data by Dance et al. [Phys. Med. Biol. 35, 1211–1219 (1990); ibid. 45, 3225–3240 (2000); ibid. 54, 4361–4372 (2009); ibid. 56, 453–471 (2011)], (c) 0.74%–0.99% on average and 3.94% maximum for the published data by Sechopoulos et al. [Med. Phys. 34, 221–232 (2007); J. Appl. Clin. Med. Phys. 9, 161–171 (2008)], and (d) 0.66%–1.33% on average and 2.72% maximum for the published data by Feng and Sechopoulos [Radiology 263, 35–42 (2012)], excluding one sample in (d) that does not follow the trends in the published data table.Conclusions: A flexible parameterization method is presented in this paper, and was applied to breast tomosynthesis dosimetry. The resultant data offer easy and accurate computations of MGD conversion factors for evaluating mean glandular breast dose in the MQSA

  2. Role of accelerator mass spectrometry in biological dosimetry

    International Nuclear Information System (INIS)

    Felton, J.S.; Turteltaub, K.W.; Frantz, C.; Vogel, J.S.; Gledhill, B.L.

    1992-01-01

    Understanding risks from exposures to carcinogens and other chemicals depends upon measurement of their dose to target tissues and their reactivity with critical macromolecules. The authors have used AMS detection of radio-isotopes to assess doses and reactivities at low, environmentally relevant doses. Several biomedical investigations show the effectiveness of quantification of biologically important events at extremely high sensitivity with AMS. Specifically, they have measured the addition of environmental carcinogens such as 2-amino-3,8-dimethylimidazo[4,5-f]-quinoaxaline (MelQx), a chemical found in cooked food, to DNA at concentrations relevant to human exposure. Other low level detection problems in biology, such as immunoassay assessment of small environmental chemicals, is being developed with attomole sensitivity. AMS also aids the assessment of genotoxic risks from chemicals by quantifying the binding of labeled chemicals to DNA. The very toxic and potent carcinogen, tetrachlorodibenzo-p-dioxin (TCDD) was assessed for DNA binding, but no detectable radiocarbon-labeled TCDD was found associated with mouse liver DNA at less than systematically toxic levels. The data indicate that a mutation mechanism does not mediate TCDD carcinogenesis

  3. Personnel β-dosimetry method for reducing energy dependence

    International Nuclear Information System (INIS)

    Gesell, T.F.; Jones, D.E.; Gupta, V.P.; Kalbeitzer, F.L.; Cusimano, J.P.

    1979-03-01

    Current practices for the measurement of skin dose are reviewed and found to be inadequate. The current INEL dosimeter was examined for systematic and random error. Systematic (i.e., variation with energy) error was found to range over a factor of 10 while the random error was reasonably small for the larger β/γ ratios. Other designs with thicker windows as is more common would show even larger systematic errors. Various methods for improving beta dosimetry were reviewed. A new dosimeter design utilizing three chips, each having a window of difference thickness, was proposed. According to the calculations, this dosimeter should markedly reduce systematic error but will introduce somewhat more random error. Preliminary measurements were carried out related to angular dependence and charged particle equilibrium. The proposed dosimeter design was tested with betas from a uranium slab. The average of the seven results was in excellent agreement with the known dose rate and the standard deviation of the result was 16%

  4. Biological detector and method

    Science.gov (United States)

    Sillerud, Laurel; Alam, Todd M; McDowell, Andrew F

    2013-02-26

    A biological detector includes a conduit for receiving a fluid containing one or more magnetic nanoparticle-labeled, biological objects to be detected and one or more permanent magnets or electromagnet for establishing a low magnetic field in which the conduit is disposed. A microcoil is disposed proximate the conduit for energization at a frequency that permits detection by NMR spectroscopy of whether the one or more magnetically-labeled biological objects is/are present in the fluid.

  5. A method of dosimetry for synchrotron microbeam radiation therapy using radiochromic films and microdensitometry

    International Nuclear Information System (INIS)

    Crosbie, J. C.; Svalbe, I. D.; Lewis, R. A.

    2007-01-01

    Full text: Normal tissue displays an exceptional tolerance to high doses of radiation (hundreds of Gy) when delivered as a microplanar array of synchrotron-generated x-rays. Furthermore, MRT has been shown to cause significant tumour growth delay and in some case complete ablation. The biological effects of MRT on tissue are not fully understood. This is further complicated by difficulties in performing accurate dosimetry. The majority of dosimetry performed for MRT has been Monte Carlo simulations. The aim of this work was to utilise film dosimetry and microdensitometry to measure the peak-to-valley dose ratios (PVDRs) for synchrotron microbeam radiation therapy.

  6. Transient impedance changes in venous endothelial monolayers as a biological radiation dosimetry response

    Directory of Open Access Journals (Sweden)

    Erik Fossum Young

    2012-10-01

    Full Text Available In March of 2011, a magnitude 9.0 earthquake and subsequent 14 m-high tsunami caused major damage to the Fukushima Daiichi nuclear power plant in Japan.  While cancer incidence in the radiation-exposed population is a logical concern, the complex effects of radiation on the heart and cardiovascular system are also of interest.  Immediate and early vascular radiation effects could be exploited as a dosimetry modality.  To test whether non-coronary vasculature exhibited transient perturbation in barrier function, video microscopy studies and Electric Cell Substrate Impedance Sensing technology were used to probe very subtle changes in primary human vascular endothelium.  Human umbilical vein endothelial cell (HUVEC monolayers exhibit a transient, statistically significant decrease (P = 0.017 in monolayer resistance 3 h after irradiation with 5.0 Gy of g rays.  Radiation induced perturbations in HUVEC monolayer permeability are similar in magnitude and kinetics to those observed in coronary arterial endothelium.  Therefore, at least two types of vasculature respond to radiation on ECIS arrays with an early transient disruption in permeability.  The finding supports the use of early passage HUVECs for use in bioelectric dosimetry studies of vasculature and suggests that permeability of vessels could potentially serve as a biological dosimetry tool.

  7. Conventional radiation-biological dosimetry using frequencies of unstable chromosome aberrations

    International Nuclear Information System (INIS)

    Ramalho, Adriana T.; Costa, Maria Lucia P.; Oliveira, Monica S.

    1998-01-01

    Frequency of chromosome aberrations detected by conventional cytogenetics is a very useful parameter in biological radiodosimetry. It can be used for estimating absorbed doses in individuals working with radioactive sources and individuals accidentally exposed to radiation. In the first case subjects wear physical dosimeters as a routine safety habit. The laboratory at the Institute of Radioprotection and Dosimetry (IRD, Brazil) has been using conventional cytogenetic analysis to complement data obtained by physical dosimetry since 1983. Until now, more than one hundred cases were investigated where individual physical dosimeters detected occupational exposure (above the safety limits allowed). In total, only 34% of these cases were confirmed by conventional cytogenetic dosimetry. Also, conventional cytogenetic analysis following the radiation accident of Goiania (Brazil) in 1987 have been used. Peripheral lymphocytes from 129 exposed or potentially exposed individuals were analyzed for the frequencies of unstable chromosomal aberrations (dicentrics, centric rings and acentrics fragments) to estimate absorbed radiation doses. During the emergency period, doses were estimated to help immediate medical treatment using in vitro calibration curves produced before the accident. Later on, doses were assessed once more using new in vitro calibration curves. A drawback of this technique is that unstable aberrations are lost after exposure. To investigate the mean lifespan of lymphocytes containing dicentric and ring aberrations, we have followed 15 victims of the Goiania accident over all these years. Results suggest that the disappearance of unstable aberrations is dose-dependent. This could explain the variation in the results found among studies in this field

  8. Conventional radiation-biological dosimetry using frequencies of unstable chromosome aberrations

    Energy Technology Data Exchange (ETDEWEB)

    Ramalho, Adriana T.; Costa, Maria Lucia P.; Oliveira, Monica S. [Institute of Radioprotection and Dosimetry (IRD), National Commission of Nuclear Energy (CNEN), Av. Salvador Allende, Cx. P. 37750, Rio de Janeiro 22.780-160 (Brazil)

    1998-08-03

    Frequency of chromosome aberrations detected by conventional cytogenetics is a very useful parameter in biological radiodosimetry. It can be used for estimating absorbed doses in individuals working with radioactive sources and individuals accidentally exposed to radiation. In the first case subjects wear physical dosimeters as a routine safety habit. The laboratory at the Institute of Radioprotection and Dosimetry (IRD, Brazil) has been using conventional cytogenetic analysis to complement data obtained by physical dosimetry since 1983. Until now, more than one hundred cases were investigated where individual physical dosimeters detected occupational exposure (above the safety limits allowed). In total, only 34% of these cases were confirmed by conventional cytogenetic dosimetry. Also, conventional cytogenetic analysis following the radiation accident of Goiania (Brazil) in 1987 have been used. Peripheral lymphocytes from 129 exposed or potentially exposed individuals were analyzed for the frequencies of unstable chromosomal aberrations (dicentrics, centric rings and acentrics fragments) to estimate absorbed radiation doses. During the emergency period, doses were estimated to help immediate medical treatment using in vitro calibration curves produced before the accident. Later on, doses were assessed once more using new in vitro calibration curves. A drawback of this technique is that unstable aberrations are lost after exposure. To investigate the mean lifespan of lymphocytes containing dicentric and ring aberrations, we have followed 15 victims of the Goiania accident over all these years. Results suggest that the disappearance of unstable aberrations is dose-dependent. This could explain the variation in the results found among studies in this field

  9. Dosimetry using environmental and biological materials. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Haskell, E.; Kenner, G.; Hayes, R.

    1996-09-01

    Although theoretical models have been the traditional tool for assessment of doses delivered by nuclear accidents, their use is now accompanied by increasing political and scientific demand for physical measurements which provide site specific dose information related directly to the original events, can be used to verify and augment the theoretical models, and can be performed and reflicated by independent laboratories. This report details a four year effort to improve the sensitivity and reliability of retrospective methods, to collaborate with laboratories engaged in related research, and to share the technology with startup laboratories seeking similar capabilities.

  10. Biological (DB) and internal dosimetry (DI) in patients with differentiated thyroid carcinoma (CaDT) treated with iodine 131

    International Nuclear Information System (INIS)

    Fadel, Ana M.; Chebel, G.; Oneto, A.; Di Giorgio, Marina; Vallerga, Maria B.; Taja, Maria R.; Radl, A.; Rojo, Ana M.; Deluca, G.; Levi de Cabrejas, Mariana; Cabrejas, Raul C.

    2009-01-01

    The internal 131 I radiotherapy in patients with CaDT is used within the therapeutic scheme as a step post-thyroidectomy. The success of therapy is to achieve a lethal dose in the tumor tissue without exceeding the dose of tolerance in healthy tissues (doses greater than 2 Gy in bone marrow could lead to myelotoxicity). In this work, the treatment protocol applied incorporates assessment by biological (DB) and internal dosimetry (DI) for estimating doses to the whole body and bone marrow to administer a therapeutic personalized for each patient. The estimate biological dose is based in the quantification of chromosomal aberrations, which is referred to a dose-response curve. Objectives: 1) To estimate the absorbed dose to the whole body and bone marrow due to the administration of 131 I therapy in patients with CaDT, by applying three different cytogenetic tests: conventional cytogenetics, micronuclei (MN) and fluorescence in situ hybridization (FISH); 2) Assess the correlation of the results obtained by DB and DI for personalization of treatment. Materials and methods: We evaluated 24 patients with CaDiT by applying the cytogenetic tests mentioned and internal dosimetry (methodology Mird-Olinda). Internal dosimetry: We administered a tracer dose 74 to 111 MBq. Measurements were made of activity in whole body and blood. By adjusting the scheme was estimated MIRD dose in bone marrow and the maximum therapeutic activity to manage and secure. Through software Olinda was determined absorbed dose to the whole body for each patient. We considered patient-specific data (physical frame size, weight, hematocrit) to adjust the methodology in each particular case. It is assumed that the tracer activity administered has a kinetic in the body similar to the 131 I to be administered in therapeutic amounts. Biology Dosimetry : We performed for each patient taking 2 sequential venous blood samples to estimate the dose due to therapeutic activity in review: the first shows, pre

  11. Studies with encapsulated 125I sources: dosimetry for determination of relative biological effectiveness

    International Nuclear Information System (INIS)

    Goldhagen, P.; Freeman, M.L.; Hall, E.J.

    1981-01-01

    During the past year, members of this laboratory have measured the Relative Biological Effectiveness (RBE) of photons from encapsulated 125 I sources (mean energy = 28.33 keV) using 661.6 keV 137 Cs gamma rays as a standard for comparison. These experiments were performed at clinically relevant dose rates and used reduction of the reproductive viability of mammalian cells as an endpoint. This section will discuss how dosimetry problems special to 125 I influence the design of the apparatus and will describe the ionization chamber to be used for measuring dose rates from both 125 I and 137 Cs photons

  12. Metabolomics in Radiation-Induced Biological Dosimetry: A Mini-Review and a Polyamine Study

    Directory of Open Access Journals (Sweden)

    Changhyun Roh

    2018-05-01

    Full Text Available In this study, we elucidate that polyamine metabolite is a powerful biomarker to study post-radiation changes. Metabolomics in radiation biodosimetry, the application of a metabolomics analysis to the field of radiobiology, promises to increase the understanding of biological responses by ionizing radiation (IR. Radiation exposure triggers a complex network of molecular and cellular responses that impacts metabolic processes and alters the levels of metabolites. Such metabolites have potential as biomarkers for radiation dosimetry. Among metabolites, polyamine is one of many potential biomarkers to estimate radiation response. In addition, this review provides an opportunity for the understanding of a radiation metabolomics in biodosimetry and a polyamine case study.

  13. Chromosomal analysis and application of biological dosimetry in two cases of apparent over exposure

    International Nuclear Information System (INIS)

    Guerrero C, C.; Brena V, M.

    2002-01-01

    The gamma radiation calibration curve of 60 Co is used which was generated in the ININ Laboratory of Biology to calculate the exposure dose of two workers whose dosemeters marked values above of the limit allowed. The analysis indicates that in a first case, the aberrations frequency corresponded to the basal value, therefore there is not over exposure. The aberrations frequency of the second case is lightly above to the basal value and therefore the probability favors to what the physical dosimetry indicates. (Author)

  14. Bibliographical database of radiation biological dosimetry and risk assessment: Part 1, through June 1988

    Energy Technology Data Exchange (ETDEWEB)

    Straume, T.; Ricker, Y.; Thut, M.

    1988-08-29

    This database was constructed to support research in radiation biological dosimetry and risk assessment. Relevant publications were identified through detailed searches of national and international electronic databases and through our personal knowledge of the subject. Publications were numbered and key worded, and referenced in an electronic data-retrieval system that permits quick access through computerized searches on publication number, authors, key words, title, year, and journal name. Photocopies of all publications contained in the database are maintained in a file that is numerically arranged by citation number. This report of the database is provided as a useful reference and overview. It should be emphasized that the database will grow as new citations are added to it. With that in mind, we arranged this report in order of ascending citation number so that follow-up reports will simply extend this document. The database cite 1212 publications. Publications are from 119 different scientific journals, 27 of these journals are cited at least 5 times. It also contains reference to 42 books and published symposia, and 129 reports. Information relevant to radiation biological dosimetry and risk assessment is widely distributed among the scientific literature, although a few journals clearly dominate. The four journals publishing the largest number of relevant papers are Health Physics, Mutation Research, Radiation Research, and International Journal of Radiation Biology. Publications in Health Physics make up almost 10% of the current database.

  15. Bibliographical database of radiation biological dosimetry and risk assessment: Part 1, through June 1988

    International Nuclear Information System (INIS)

    Straume, T.; Ricker, Y.; Thut, M.

    1988-01-01

    This database was constructed to support research in radiation biological dosimetry and risk assessment. Relevant publications were identified through detailed searches of national and international electronic databases and through our personal knowledge of the subject. Publications were numbered and key worded, and referenced in an electronic data-retrieval system that permits quick access through computerized searches on publication number, authors, key words, title, year, and journal name. Photocopies of all publications contained in the database are maintained in a file that is numerically arranged by citation number. This report of the database is provided as a useful reference and overview. It should be emphasized that the database will grow as new citations are added to it. With that in mind, we arranged this report in order of ascending citation number so that follow-up reports will simply extend this document. The database cite 1212 publications. Publications are from 119 different scientific journals, 27 of these journals are cited at least 5 times. It also contains reference to 42 books and published symposia, and 129 reports. Information relevant to radiation biological dosimetry and risk assessment is widely distributed among the scientific literature, although a few journals clearly dominate. The four journals publishing the largest number of relevant papers are Health Physics, Mutation Research, Radiation Research, and International Journal of Radiation Biology. Publications in Health Physics make up almost 10% of the current database

  16. Biological dosimetry of heavy ion induced chromosome lesions in human peripheral blood lymphocytes of different healthy donors

    International Nuclear Information System (INIS)

    Groesser, T.; Rydberg, B.; Ritter, S.; Hessel, P.; Kraft, G.

    2003-01-01

    Full text: In the presented work the effect of sparsely ionizing X-rays or densely ionizing carbon ions on human peripheral blood lymphocytes (PBL) from healthy donors regarding the fluctuations in radiosensitivity within the same donor and between different donors was examined. This is not only of special interest for physicians and radiation biologists but also plays an important role in space flights because such fluctuations in the radiation response would reduce the accuracy of the biological dosimetry. In this context, biological changes in the aberration rate of metaphase cells as well as in cell proliferation and the mitotic index were measured. Since chromosome analyses are presently the most powerful biological method to quantify radiation exposure, the study focused on the measurements of chromosome aberrations in first-metaphase cells. The investigations showed that the aberration yield after 400 MeV/u carbon ion exposure (LET = 11 keV/micrometer) was higher than after X-irradiation. The aberration yield in first mitotic cells as well as the proportion of damaged cells was stable over the examined period up to 72h after exposure to X-rays or carbon ions. Furthermore, the results of the presented work revealed pronounced fluctuations in the measured parameters in the same donor as well as between different donors. If the dose effect curves of such parameters were used as calibration curves for radiation dose assessment these fluctuations will decrease their potential of use for dose estimation. This demonstrates that a general calibration curve for dose assessment might not be sufficiently precise and individual calibration curves might improve the accuracy of the biological dosimetry

  17. Fast film dosimetry calibration method for IMRT treatment plan verification

    International Nuclear Information System (INIS)

    Schwob, N.; Wygoda, A.

    2004-01-01

    Intensity-Modulated Radiation Therapy (IMRT) treatments are delivered dynamically and as so, require routinely performed verification measurements [1]. Radiographic film dosimetry is a well-adapted method for integral measurements of dynamic treatments fields, with some drawbacks related to the known problems of dose calibration of films. Classically, several films are exposed to increasing doses, and a Net Optical Density (N.O.D) vs. dose sensitometric curve (S.C.) is generated. In order to speed up the process, some authors have developed a method based on the irradiation of a single film with a non-uniform pattern of O.D., delivered with a dynamic MLC. However, this curve still needs to be calibrated to dose by the means of measurements in a water phantom. It is recommended to make a new calibration for every series of measurements, in order to avoid the processing quality dependence of the film response. These frequent measurements are very time consuming. We developed a simple method for quick dose calibration of films, including a check of the accuracy of the calibration curve obtained

  18. Cytogenetic techniques for biological indications and dosimetry of of radiation damages in humans

    International Nuclear Information System (INIS)

    Hadjidekova, V.

    2003-01-01

    The cytogenetic methods present a proved way for bio-monitoring and bio-dosimetry for persons, submitted to ionising radiation in occupational and emergency conditions. Their application complement and assist the evaluation of the physical dosimetry and takes in account the individual radiosensitivity of the organism. A comparative assessment is made of the cytogenetic markers for radiation damage of humans applied in Bulgaria. It is discussed the sensitivity of the methods and their development in the last years, as well as the basic concept for their application - the causal relationship between the frequency of the observation of cytogenetic markers in peripheral blood lymphocytes and the risk of oncological disease. The conventional analysis of dicentrics is recognised as a 'golden standard' for the quantitative assessment of the radiation damage. The long term persisting translocations reflect properly the cumulative dose burden from chronic exposure. The micronucleus test allows a quick screening of large groups of persons, working in ionising radiation environment. The combined application with centromeric DNA probe improves the sensitivity and presents a modern alternative of the bio-monitoring and bio-dosimetry. It is discussed the advantages of the different cytogenetic techniques and their optimised application for the assessment of the radiation impact on humans

  19. Effect of contrast agent administration on consequences of dosimetry and biology in radiotherapy planning

    International Nuclear Information System (INIS)

    Lo, Ching-Jung; Yang, Pei-Ying; Chao, Tsi-Chian; Tu, Shu-Ju

    2015-01-01

    In the treatment planning of radiation therapy, patients may be administrated with contrast media in CT scanning to assist physicians for accurate delineation of the target or organs. However, contrast media are not used in patients during the treatment delivery. In particular, contrast media contain materials with high atomic numbers and dosimetric variations may occur between scenarios where contrast media are present in treatment planning and absent in treatment delivery. In this study we evaluate the effect of contrast media on the dosimetry and biological consequence. An analytical phantom based on AAPM TG 119 and five sets of CT images from clinical patients are included. Different techniques of treatment planning are considered, including 1-field AP, 2-field AP+PA, 4-field box, 7-field IMRT, and RapidArc. RapidArc is a recent technique of volumetric modulated arc therapy and is used in our study of contrast media in clinical scenarios. The effect of RapidArc on dosimetry and biological consequence for administration of contrast media in radiotherapy is not discussed previously in literature. It is shown that dose difference is reduced as the number of external beams is increased, suggesting RapidArc may be favored to be used in the treatment planning enhanced by contrast media. Linear trend lines are fitted for assessment of percent dose differences in the planning target volume versus concentrations of contrast media between plans where contrast media are present and absent, respectively

  20. Computational methods in several fields of radiation dosimetry

    International Nuclear Information System (INIS)

    Paretzke, Herwig G.

    2010-01-01

    Full text: Radiation dosimetry has to cope with a wide spectrum of applications and requirements in time and size. The ubiquitous presence of various radiation fields or radionuclides in the human home, working, urban or agricultural environment can lead to various dosimetric tasks starting from radioecology, retrospective and predictive dosimetry, personal dosimetry, up to measurements of radionuclide concentrations in environmental and food product and, finally in persons and their excreta. In all these fields measurements and computational models for the interpretation or understanding of observations are employed explicitly or implicitly. In this lecture some examples of own computational models will be given from the various dosimetric fields, including a) Radioecology (e.g. with the code systems based on ECOSYS, which was developed far before the Chernobyl reactor accident, and tested thoroughly afterwards), b) Internal dosimetry (improved metabolism models based on our own data), c) External dosimetry (with the new ICRU-ICRP-Voxelphantom developed by our lab), d) Radiation therapy (with GEANT IV as applied to mixed reactor radiation incident on individualized voxel phantoms), e) Some aspects of nanodosimetric track structure computations (not dealt with in the other presentation of this author). Finally, some general remarks will be made on the high explicit or implicit importance of computational models in radiation protection and other research field dealing with large systems, as well as on good scientific practices which should generally be followed when developing and applying such computational models

  1. An accurate method of 131I dosimetry in the rat thyroid

    International Nuclear Information System (INIS)

    Lee, W.; Shleien, B.; Telles, N.C.; Chiacchierini, R.P.

    1979-01-01

    An accurate method of thyroid 131 I dosimetry was developed by imploying the dose formulation recommended by the Medical Internal Radiation Dose (MIRD) Committee. Six-week-old female Long-Evans rats were injected intraperitonealy with 0.5, 1.9, and 5.4 μCi of Na 131 I. The accumulated 131 I activities in the thyroid were precisely determined by integrating the 131 I activities per gram of the thyroid as functions of postinjection time. When the mean thyroid doses derived from this method are compared to those derived from the conventional method, the conventional method over-estimated the doses by 60 to 70%. Similarly, the conventional method yielded effective half-lives of 2.5 to 2.8 days; these estimates were found to be high by factors of 1.4 to 2.0. This finding implies that the biological elimination of iodide from the rat thyroid is much more rapid (up to 2.5 times) that once believed. Results from this study showed that the basic assumption in the conventional method of thyroid 131 I dosimetry in the rat, i.e., that the thyroid iodide retention function is a single exponential, is invalid. Results from this study also demonstrated that variations in animal body weight of 6 to 7-week-old animals and diurnal variation have no significant influence on the mean thyroid doses for a given injected activity of 131 I. However, as expected, variation in iodide content of the animal diets significantly altered the thyroid doses for a given 131 I injected activity

  2. A retrospective dosimetry method and its uncertainty analysis

    International Nuclear Information System (INIS)

    Zhang, L.; Jia, D.; Dai, G.

    2000-01-01

    The main aim of a radiation epidemiological study is to assess the risk of the population exposed to ionizing radiation. The actual work of the assessment may be very difficult because dose information about the population is often indirect and incomplete. It is very important, therefore, to find a way of estimating reasonable and reliable doses of the population by a retrospective method from limited information. In order to provide reasonable dose information for the cohort study of Chinese medical diagnostic X-ray workers, a retrospective dosimetry method was established. In China, a cohort study of more than 27,000 medical diagnostic X-ray workers, with 25,000 controls, has been carried out for about fifteen years in order to assess the risk to an occupationally exposed population. Obviously, a key to the success of the study is to obtain reliable and reasonable results of dose estimation by the dose reconstruction method. Before 1985, there was a lack of information regarding personal dose measured directly; however, we can obtain other indirect information. Examples are information about working loads from the documents of the hospitals, information about operational conditions of the workers of different statuses by a survey of occupational history, and the exposure levels of various working conditions by some simulation methods. The information for estimating organ dose can also be obtained by simulating experiments with a phantom. Based on the information mentioned above, a mathematical model and computerizing system for dose reconstruction of this occupational population was design and developed. Uncertainty analysis very important for dose reconstruction. The sources of uncertainty of our study are coming from two fields. One is coming from the mode of dose reconstruction. Another is coming from the survey of the occupational history. In the result reported, main results of the uncertainty will be presented. In order to control the uncertainty of the

  3. Bibliographical database of radiation biological dosimetry and risk assessment: Part 2

    International Nuclear Information System (INIS)

    Straume, T.; Ricker, Y.; Thut, M.

    1990-09-01

    This is part 11 of a database constructed to support research in radiation biological dosimetry and risk assessment. Relevant publications were identified through detailed searches of national and international electronic databases and through our personal knowledge of the subject. Publications were numbered and key worded, and referenced in an electronic data-retrieval system that permits quick access through computerized searches on authors, key words, title, year, journal name, or publication number. Photocopies of the publications contained in the database are maintained in a file that is numerically arranged by our publication acquisition numbers. This volume contains 1048 additional entries, which are listed in alphabetical order by author. The computer software used for the database is a simple but sophisticated relational database program that permits quick information access, high flexibility, and the creation of customized reports. This program is inexpensive and is commercially available for the Macintosh and the IBM PC. Although the database entries were made using a Macintosh computer, we have the capability to convert the files into the IBM PC version. As of this date, the database cites 2260 publications. Citations in the database are from 200 different scientific journals. There are also references to 80 books and published symposia, and 158 reports. Information relevant to radiation biological dosimetry and risk assessment is widely distributed within the scientific literature, although a few journals clearly predominate. The journals publishing the largest number of relevant papers are Health Physics, with a total of 242 citations in the database, and Mutation Research, with 185 citations. Other journals with over 100 citations in the database, are Radiation Research, with 136, and International Journal of Radiation Biology, with 132

  4. Biological dosimetry after criticality accidents. Intercomparison exercise in the Silene Reactor - France

    International Nuclear Information System (INIS)

    Di Giorgio, Marina; Vallerga, Maria B.; Taja, Maria R.

    2004-01-01

    The Institute of Radiation Protection and Nuclear Safety Institute (IRSN) organized an international biological dosimetry intercomparison, at the SILENE experimental reactor (Valduc, France), simulating different criticality scenarios: bare source 4 Gy, lead shield source 1 and 2 Gy and gamma pure 60 Co source 2 Gy. Fifteen laboratories were involved in this exercise, including the Argentine Biological Dosimetry Laboratory. The purposes of the intercomparison were: 1) To compare the unstable chromosome aberration (UCA) frequency observed by the different laboratories; and 2) To compare the dose estimation for gamma rays and neutrons. The objects of the present work were: I) To compare the mean frequency of UCA observed by the Argentine laboratory with the mean frequency observed by the participant laboratories as a whole. II) To compare the dose estimates performed by the Argentine lab with those estimated by the other laboratories involved in the second stage of the intercomparison. Overall, the mean frequencies of UCA and the correspondent 95% confidence limits obtained by the Argentine lab were consistent with the results obtained by the laboratories as a whole. For the gamma pure scenario, smaller variations were observed among laboratories in terms of dose (CV=18,2%) than in terms of frequency (CV=30,1%). For the mixed field scenarios, only four laboratories, including the Argentine lab, estimated gamma and neutron components of the total dose and just two (Argentine lab and lab 12) were in agreement with the given physical doses. The 1 Gy experiment presented lesser variations both in terms of frequency and dose than the other two scenarios. For the 4 and 2 Gy experiments, variations in neutron dose were more significant than variations in gamma dose, related to the magnitude of the dose. The results suggest that intercomparison exercises jointly with the accreditation of biological dosimetry by cytogenetic service laboratories, in compliance with ISO

  5. Foundations of ionizing radiation dosimetry

    International Nuclear Information System (INIS)

    Denisenko, O.N.; Pereslegin, I.A.

    1985-01-01

    Foundations of dosimetry in application to radiotherapy are presented. General characteristics of ionizing radiations and main characteristics of ionizing radiation sources, mostly used in radiotherapy, are given. Values and units for measuring ionizing radiation (activity of a radioactive substance, absorbed dose, exposure dose, integral dose and dose equivalent are considered. Different methods and instruments for ionizing radiation dosimetry are discussed. The attention is paid to the foundations of clinical dosimetry (representation of anatomo-topographic information, choice of radiation conditions, realization of radiation methods, corrections for a configuration and inhomogeneity of a patient's body, account of biological factors of radiation effects, instruments of dose field formation, control of irradiation procedure chosen)

  6. Biological Methods and Manual Development

    Science.gov (United States)

    EPA scientists conduct research to develop and evaluate analytical methods for the identification, enumeration, evaluation of aquatic organisms exposed to environmental stressors and to correlate exposures with effects on chemical and biological indicators

  7. Calibration curves for biological dosimetry; Curvas de calibracion para dosimetria biologica

    Energy Technology Data Exchange (ETDEWEB)

    Guerrero C, C.; Brena V, M. [ININ, A.P. 18-1027, 11801 Mexico D.F. (Mexico)]. E-mail cgc@nuclear.inin.mx

    2004-07-01

    The generated information by the investigations in different laboratories of the world, included the ININ, in which settles down that certain class of chromosomal leisure it increases in function of the dose and radiation type, has given by result the obtaining of calibrated curves that are applied in the well-known technique as biological dosimetry. In this work is presented a summary of the work made in the laboratory that includes the calibrated curves for gamma radiation of {sup 60} Cobalt and X rays of 250 k Vp, examples of presumed exposure to ionizing radiation, resolved by means of aberration analysis and the corresponding dose estimate through the equations of the respective curves and finally a comparison among the dose calculations in those people affected by the accident of Ciudad Juarez, carried out by the group of Oak Ridge, USA and those obtained in this laboratory. (Author)

  8. Use of unstable chromosome aberrations for biological dosimetry after the first postirradiation mitosis

    International Nuclear Information System (INIS)

    Doloy, M.T.; Malarbet, J.L.; Guedeney, G.; Bourguignon, M.; Leroy, A.; Reillaudou, M.; Masse, R.

    1991-01-01

    The loss of unstable chromosome aberrations after the first postirradiation mitosis makes their use difficult in radiation dosimetry. We describe here a method which, in a cell population observed at this stage, allows retrospective estimation of the frequencies of the unstable aberrations induced at the time of irradiation, and their use as a dosimeter. The laws controlling the behavior of unstable aberrations during mitosis were defined from a large-scale experiment on irradiated human lymphocytes. For cells undergoing the first, second, or third mitosis after irradiation, relationships were determined between the frequency, at irradiation time, of acentric fragments not arising from formation of dicentrics or rings, and the ratio of dicentrics and centric rings appearing without acentric fragments to the total number of dicentrics plus rings. On the basis of this ratio, the method described here provides an assessment of the postirradiation mitotic activity in a cell population. This assessment permitted estimation of the cell distribution and frequency of dicentrics plus centric rings, and of the frequency of acentric fragments at the time of irradiation. The use of this method for retrospective dosimetry after whole-body irradiation under various conditions of exposure is illustrated

  9. Biological effects of radiation and dosimetry in X-ray diagnostics of children

    International Nuclear Information System (INIS)

    Milkovic, Durdica; Beck, Natko; Kovac, Kornelija; Garaj-Vrhovac, Vera; Gajski, Goran

    2008-01-01

    The chest radiograms represent the basic radiological examinations of thorax. The basis for radiation protection especially in pediatrics is the exact determination of doses. The risk estimation of genome damages can be received in human peripheral blood lymphocytes using alkaline version of Comet Assay. The aim of this work was assessment and quantification of the level of DNA damage in peripheral blood lymphocytes of children during airways X-ray examinations of chest and to compare data to the dose of exposure. Doses were determined using thermoluminescence (TL) dosimetry and radiophotoluminescent (RPL) glass dosimetry system. Twenty children with pulmonary diseases, ages between 5 and 14 years were assessed. Dose measurements were conducted for poster-anterior (PA) projection on the forehead, thyroid gland, gonads, chest and back. We used a 150 kV Shimadzu CH-200 M X-ray unit. Peripheral blood samples were taken from children after and prior to X-ray exposure and were examined with the alkaline Comet Assay. Comet Assay is one of the standard techniques for assessing genome damage with variety applications in genotoxicity testing as well as fundamental research in DNA damage and repair. As a measure of DNA damage tail length was used, calculated from the centre of the head and presented in micrometers (μm). Mean value of group after irradiation was 14.04 ± 1.74 as opposed to mean value of group before irradiation that was 13.15 ± 1.33. Differences between mean tail lengths were statistically significant (P<0.05, ANOVA). In addition, correlation was found between doses in primary beam (measured on the back) and the ratio of tail length (DNA damage) before and after irradiation. Doses measured with TL and RPL dosimeters showed satisfactory agreement and both dosimetry methods are suitable for dosimetric measurements in X-ray diagnostics. (author)

  10. Analysis of MIR-18 results for physical and biological dosimetry: radiation shielding effectiveness in LEO

    International Nuclear Information System (INIS)

    Cucinotta, F.A.; Wilson, J.W.; Williams, J.R.; Dicello, J.F.

    2000-01-01

    We compare models of radiation transport and biological response to physical and biological dosimetry results from astronauts on the Mir space station. Transport models are shown to be in good agreement with physical measurements and indicate that the ratio of equivalent dose from the Galactic Cosmic Rays (GCR) to protons is about 3/2:1 and that this ratio will increase for exposures to internal organs. Two biological response models are used to compare to the Mir biodosimetry for chromosome aberration in lymphocyte cells; a track-structure model and the linear-quadratic model with linear energy transfer (LET) dependent weighting coefficients. These models are fit to in vitro data for aberration formation in human lymphocytes by photons and charged particles. Both models are found to be in reasonable agreement with data for aberrations in lymphocytes of Mir crew members: however there are differences between the use of LET dependent weighting factors and track structure models for assigning radiation quality factors. The major difference in the models is the increased effectiveness predicted by the track model for low charge and energy ions with LET near 10 keV/μm. The results of our calculations indicate that aluminum shielding, although providing important mitigation of the effects of trapped radiation, provides no protective effect from the galactic cosmic rays (GCR) in low-earth orbit (LEO) using either equivalent dose or the number of chromosome aberrations as a measure until about 100 g/cm 2 of material is used

  11. Biological dosimetry in patients with differenced thyroid carcinoma treated with Iodine-131

    International Nuclear Information System (INIS)

    Vallerga, M.; Taja, Maria R.; Radl, A.; Rojo, Ana M.; Deluca, G.; Di Giogio, Marina; Fadel, A.; Chebel, G.; Oneto, A.; Cabrejas, Mariana

    2007-01-01

    The differentiated thyroid carcinoma (DTC), constitutes the 90 % of the thyroid gland cancers. 80% of patients are cured after the initial therapy and 12% remained disease-free after successive treatments. The 24 patients included in this study represent a sample of the aforementioned 12% and 8%, with recurrence in the first decade post-treatment (local disease and/or recurrence at distance). The internal radiotherapy with 131 I in patients with DTC is used within the therapeutic schema as a step post-thyroidectomy. The success of the therapy is to get a lethal dose in the tumor tissue, which depends on the therapeutic activity and the retention of 131 I, without exceeding the dose of tolerance in healthy tissues. The most widespread way of administration is the empirical prescription which considers the clinical and laboratory parameters for its determination. In this work, the treatment protocol applied incorporates assessment by biological (DB) and internal (DI) dosimetry for estimating absorbed dose to the whole body and bone marrow to manage a personalized therapeutic dose for each patient. The biological dose estimation is based on the quantification of chromosomal aberrations, which is often referred to a dose-response curve in which lymphocytes are irradiated in vitro with 131 I, allowing to determine the dose in vivo of circulating lymphocytes patients [es

  12. Biological dosimetry: the potential use of radiation-induced apoptosis in human T-lymphocytes

    International Nuclear Information System (INIS)

    Menz, R.; Andres, R.; Larsson, B.; Ozsahin, M.; Crompton, N.E.A.; Trott, K.

    1997-01-01

    An assay for biological dosimetry based on the induction of apoptosis in human T-lymphocytes is described. Radiation-induced apoptosis was assessed by flow cytometric identification of cells displaying apoptosis-associated DNA condensation. CD4 and CD8 T-lymphocytes were analysed. They were recognized on the basis of their cell-surface antigens. Four parameters were measured for both cell types: cell size, granularity, antigen immunofluorescence and DNA content. Apoptosis was quantified as the fraction of CD4-, or CD8-positive cells with a characteristic reduction of cell size and DNA content. At doses below 1 Gy, levels of radiation-induced apoptosis increased for up to 5 days after irradiation. Optimal dose discrimination was observed 4 days after irradiation, at which time the dose-response curves were linear, with a slope of 8% ± 0.5% per 0.1 Gy. In controlled, dose-response experiments the lowest dose level at which the radiation-induced apoptosis frequency was still significantly above control was 0.05 Gy. After 5 days post-irradiation incubation, intra- and interdonor variations were measured and found to be similar; thus, apoptotic levels depend more on the dose than on the donor. The results demonstrate the potential of this assay as a biological dosimeter. (orig.)

  13. Challenges of analysing suspected over exposed subjects using biological dosimetry at Sri Ramachandra University

    International Nuclear Information System (INIS)

    Vijayalakshimi, J.; Venkatachalam, P.; Solomon, F.D. Paul

    2016-01-01

    Biological dosimetry based on the analysis of dicentric chromosomes has become a routine component of the radiological protection programmes and has a valuable role to contribute in suspected over exposed subjects who perform diagnostic and therapeutic procedures. The Department of Human Genetics, Sri Ramachandra University, Porur, Chennai, has been involved in the standardization of chromosomal aberration analysis as a biological dosimeter for investigating accidental ionising radiation exposure since 1998. Our laboratory has been accredited since 2007 by Atomic Energy Regulatory Board. The initial process was to establish the in vitro dose response curve for various type of low LET ionizing radiation. Since accreditation, a total of 61 subjects have been referred to Sri Ramachandra University from SRRC, Kalpakkam. Brief social/medical history and informed consent are being obtained prior to blood samplings. The dose estimates expressed in sievert (Sv) measured by Thermoluminescence badges was in the range of 0.05-2779.05 mSv. Chromosomal aberration assay was used for analysis which allows direct detection of aberration in peripheral blood lymphocytes. The test was performed as per the standard operating protocol on peripheral blood lymphocyte. Currently the dose response curve for the automated scoring process in under way and we hope to improve upon quality and turnaround time using the automation available. Future challenge would be to establish an in vitro dose response curve with automated scoring technique and developing inter-laboratory comparison of dose response generated using automation

  14. Use of FISH-translocations analyses for retrospective biological dosimetry: How stable are stable chromosome aberrations?

    International Nuclear Information System (INIS)

    Darroudi, F.

    2000-01-01

    Chromosome aberrations, in particular dicentrics, in peripheral blood lymphocytes are used to estimate the absorbed dose immediately following a radiation accident. However, difficulties for dose estimation arise with old exposures, due to a decline of cells containing unstable dicentric aberrations. The fluorescence in situ hybridisation (FISH) technique employing chromosome specific DNA libraries to 'paint' individual human chromosomes has opened new perspectives for rapid and reliable detection of stable chromosome aberrations such as translocations. The inherent stability of translocations over cell generations has enabled them to be used as a biodosemeter. However, due to the limited life of circulating T-lymphocytes, a level of uncertainty exists on the long-term persistence of stable translocations. The objectives of the present work are to present the current state of knowledge on the stability of translocations detected by FISH. The following aspects have been considered; (1) experience so far of retrospective biological dosimetry in humans following accidental and occupational over-exposure, (2) animal studies using mice and monkeys, (3) the influence of subsequent cell divisions on the yield and persistence of translocations following in vitro irradiation of human lymphocytes, and (4) the needs for further work to standardise and validate the use of FISH as a biological dosemeter, and to investigate the influence of various parameters such as radiation quality, dose rate and the discrimination of sub-types of translocations on persistence. (author)

  15. Biological Dosimetry of In Vitro Irradiation with Radionuclides : Comparison of Whole Blood, Lymphocyte and Buffy Coat Culture

    International Nuclear Information System (INIS)

    Kim, Jong Ho; Lee, Dong Soo; Choi, Chang Woon; Chung, June Key; Lee, Myung Chul; Koh, Chang Soon; Kim, Chong Soon; Kim, Hee Geun; Kang, Duck Won; Song, Myung Jae

    1995-01-01

    The purpose of this study was to establish mononuclear cell cultures such as lymphocytes or buffy coat for the biological dosimetry of in vitro irradiation of the radionuclide Tc-99m in order to exclude the effect of residual doses seen in the cultures of whole blood. Biological dosimetry of Tc-99m on cultured mononuclear cells at doses ranging from 0.05 to 6.00 Gy, by scoring unstable chromosomal aberrations(Ydr) observed in cultured lymphocytes, were performed using peripheral venous blood of healthy normal person. The results showed that; (1) In vitro irradiation of radioisotope in separated lymphocyte or buffy coat showed trace amount af residual doses of isotope after washing. Residual doses of isotopes are increased in proportion tn exposed time and irradiated dose without difference between I-131 anct Tc-99m. (2) We obtained these linear-quadratic dose response equations in lymphocyte and buffy coat culture after in vitro irradiation of Tc-99m, respectively (Ydr = 0,001949 D 2 +0,006279D+ 0.000185; Ydr= 0.002531 D 2 -0.003274 D+0.003488). In conclusion, the linear quadrstic dose response equation from in vitro irradiation of Tc-99m with lymphocyte and buffy coat culture was thought to be useful for assessing Tc-99m indueed biological effects. And mononuclear cell cultures seem to be the most appropriate experimental model for the assessment of biological dosimetry of internal irradiation of radionuclides.

  16. Biology, Philosophy, and Scientific Method.

    Science.gov (United States)

    Hill, L.

    1985-01-01

    The limits of falsification are discussed and the historically based models of science described by Lakatos and Kuhn are shown to offer greater insights into the practice of science. The theory of natural selection is used to relate biology to philosophy and scientific method. (Author/JN)

  17. Tangential breast irradiation - rationale and methods for improving dosimetry

    International Nuclear Information System (INIS)

    Neal, A.J.; Mayles, W.P.M.; Yarnold, J.R.

    1994-01-01

    In recent years there have been great advances and innovations in all technical aspects of radiotherapy, including three dimensional (3D) computer planning, patient immobilization, radiation delivery and treatment verification. Despite this progress, the technique of tangential breast irradiation has changed little over this period and has not exploited these advances. There is increasing evidence that dose inhomogeneity within the breast is greater than at other anatomical sites, especially in women with large breasts. This paper is a review of the factors contributing to poor dosimetry in the breast, the clinical consequences of an inhomogeneous dose distribution, and how breast dosimetry could be improved by considering each of the stages from planning to accurate treatment delivery. It also highlights the particular problem of women with large breasts who may be more likely to have a poorer outcome after a fractionated course of radiotherapy than women with small/medium-sized breasts, and supports the clinical impression that such women are also more likely to have greater inhomogenicity when 3D treatment plans are examined. Preliminary data from our current computed tomography (CT) planning study are presented to support these observations. (author)

  18. A new method of readout in radiochromic film dosimetry

    International Nuclear Information System (INIS)

    Kellermann, Peer Oliver; Gornik, Erich; Ertl, Adolf

    1998-01-01

    Radiochromic film as a dosimetry medium offers several advantages in high-resolution radiography. A new technique of readout was developed to measure the optical density distributions of the film in purely directed light. This technique implements radiochromic film dosimetry near the film's absorption maximum by using a single-mode top-surface emitting laser diode (675.2 nm). The effective sensitivity of the film, compared with a helium-neon laser densitometer (632.8 nm), is increased approximately threefold. Good accuracy, high spatial resolution and simple assembly of the readout system is achieved. Beam profiles of the four final collimator helmets of a Leksell Gamma Knife (Elekta Inc., Sweden) were experimentally determined. Measured profiles and full-widths at half maximum are consistent with the computer generated data of the dose planning system (Kula 4.4, Elekta Inc., Sweden). The output factor of the 4 mm collimator (the smallest collimator with the steepest dose gradient), essential for the application of well defined doses, was checked. The measurements established an output factor of 826±9 that lies 9±1% lower than the adjusted one. (author)

  19. Supporting Treatment Decisions in Patients with Differentiated Thyroid Carcinoma (DTC) under Radioiodine-131 Therapy: Role of Biological Dosimetry Assessment

    International Nuclear Information System (INIS)

    Fadel, A.M.; Chebel, G.M.; Di Giorgio, M.; Vallerga, M.B.; Taja, M.R.; Radl, A.; Bubniak, R.V.; Oneto, A.

    2010-01-01

    Radioiodine-131 therapy is applied in patients with differentiated thyroid carcinoma (DTC), within the therapeutic scheme following thyroidectomy, for the ablation of thyroid remnants and treatment of metastatic disease. Several approaches for the selection of a therapeutic dose were applied. The aim of this therapy is to achieve a lethal dose in the tumor tissue, without exceeding the dose of tolerance in healthy tissues (doses greater than 2 Gy in bone marrow could lead to myelotoxicity). In this work, the treatment protocol used incorporates the assessment by biological dosimetry (BD) for estimating doses to whole body and bone marrow, to tailor patient's treatment. Biological Dosimetry prospective studies conducted on samples from patients with cumulative activities, before and after each therapeutic administration, allows to evaluate DNA damage and repair capacity in peripheral blood lymphocytes. (authors)

  20. Mathematical methods in systems biology.

    Science.gov (United States)

    Kashdan, Eugene; Duncan, Dominique; Parnell, Andrew; Schattler, Heinz

    2016-12-01

    The editors of this Special Issue of Mathematical Biosciences and Engineering were the organizers for the Third International Workshop "Mathematical Methods in System Biology" that took place on June 15-18, 2015 at the University College Dublin in Ireland. As stated in the workshop goals, we managed to attract a good mix of mathematicians and statisticians working on biological and medical applications with biologists and clinicians interested in presenting their challenging problems and looking to find mathematical and statistical tools for their solutions.

  1. Application of numerical analysis methods to thermoluminescence dosimetry; Aplicacion de metodos de analisis numerico a la dosimetria por termoluminiscencia

    Energy Technology Data Exchange (ETDEWEB)

    Gomez Ros, J M; Delgado, A

    1989-07-01

    This report presents the application of numerical methods to thermoluminescence dosimetry (TLD), showing the advantages obtained over conventional evaluation systems. Different configurations of the analysis method are presented to operate in specific dosimetric applications of TLD, such as environmental monitoring and mailed dosimetry systems for quality assurance in radiotherapy facilities. (Author) 10 refs.

  2. Method to detect biological particles

    International Nuclear Information System (INIS)

    Giaever, I.

    1976-01-01

    A medical-diagnostic method to detect immunological as well as other specific reactions is described. According to the invention, first reactive particles (e.g. antibodies) are adsorbed on the surface of a solid, non-reactive substrate. The coated substrate is subjected to a solution which one assumes to contain the second biological particles (e.g. antigens) which are specific to the first and form complexes with these. A preferential radioactive labelling (e.g. with iodine 125) of the second biological particle is then directly or indirectly carried out. Clearage follows labelling in order to separate the second biological particles from the first ones. A specific splitting agent can selectively break the bond of both types of particle. The splitting agent solution is finally separated off and its content is investigated for the presence of labelling. (VJ) [de

  3. The future of new calculation concepts in dosimetry based on the Monte Carlo Methods

    International Nuclear Information System (INIS)

    Makovicka, L.; Vasseur, A.; Sauget, M.; Martin, E.; Gschwind, R.; Henriet, J.; Vasseur, A.; Sauget, M.; Martin, E.; Gschwind, R.; Henriet, J.; Salomon, M.

    2009-01-01

    Monte Carlo codes, precise but slow, are very important tools in the vast majority of specialities connected to Radiation Physics, Radiation Protection and Dosimetry. A discussion about some other computing solutions is carried out; solutions not only based on the enhancement of computer power, or on the 'biasing'used for relative acceleration of these codes (in the case of photons), but on more efficient methods (A.N.N. - artificial neural network, C.B.R. - case-based reasoning - or other computer science techniques) already and successfully used for a long time in other scientific or industrial applications and not only Radiation Protection or Medical Dosimetry. (authors)

  4. Statistical methods to evaluate thermoluminescence ionizing radiation dosimetry data

    International Nuclear Information System (INIS)

    Segre, Nadia; Matoso, Erika; Fagundes, Rosane Correa

    2011-01-01

    Ionizing radiation levels, evaluated through the exposure of CaF 2 :Dy thermoluminescence dosimeters (TLD- 200), have been monitored at Centro Experimental Aramar (CEA), located at Ipero in Sao Paulo state, Brazil, since 1991 resulting in a large amount of measurements until 2009 (more than 2,000). The data amount associated with measurements dispersion, since every process has deviation, reinforces the utilization of statistical tools to evaluate the results, procedure also imposed by the Brazilian Standard CNEN-NN-3.01/PR- 3.01-008 which regulates the radiometric environmental monitoring. Thermoluminescence ionizing radiation dosimetry data are statistically compared in order to evaluate potential CEA's activities environmental impact. The statistical tools discussed in this work are box plots, control charts and analysis of variance. (author)

  5. Dosimetry comparison of pelvimetry methods using conventional radiographs and CT

    International Nuclear Information System (INIS)

    Resten, A.; Suissa, M.; Musset, D.; Mausoleo, F.; Valero, M.; Taylor, S.

    2001-01-01

    To determine the fetal and maternal exposure to radiation by use of thermoluminescent dosimeters in order to compare conventional and CT-scan X-ray. Dosimetry was performed with an anthropomorph phantom. Thermoluminescent dosimeters were positioned on the surface and in the depth of the phantom. Digital radiography of the pelvis was performed according to a standard technique. CT-scan of the pelvis was performed according to the Buthiau's technique. With CT, the dose reached 0.31 to 4.95 mGy, with a dose of 2.32 mGy for the fetal gonads. With standard technique, the doses reached 0.03 to 0.39 mGy, with a dose of 0.39 mGy for the fetal gonads. With CT the fetus and the mother were exposed to 1/10. of the total dose delivered using conventional X-rays and the dose distribution was more homogeneous. (author)

  6. The application of calorimetrical methods in nuclear technology and dosimetry

    International Nuclear Information System (INIS)

    Kott, J.; Krett, V.; Novotny, J.; Kovar, Z.; Jirousek, V.

    1985-01-01

    The report reviews theoretical as well as experimental research activities devoted to the possibilities of measuring reactor neutron and photon fields using thermic detectors based on calorimetric principle. There have been worked out theoretical principles of a reactor measuring probe intended in the first place to measuring neutron fluxes under operational temperatures inside power and research reactors, and a new philosophy of measurement has been elaborated. In addition, the report presents the experimental results as obtained on research reactors WWR-S, WWR-SM, RA, and Czechoslovak power reactor A-1 and GDR power reactor WWR-2. These results are given in connection with a newly proposed technique of reactor neutron field detection. The second part of the report presents results of works concerning beam dosimetry with the use of calorimeters

  7. Some methods for calibration and beta radiation dosimetry

    International Nuclear Information System (INIS)

    Caldas, Linda V. Ehlin

    1980-01-01

    The calibration of beta radiation was studied from the point of view of primary and secondary standardization, using extrapolation chambers and examining several effects. The properties of a commercial ionization chamber were investigated, and the possibility of its use in calibration and dosimetry of 90 Sr- 90 Y beta radiation was demonstrated . A secondary standard calibration facility was developed and the results obtained with this facility were compared with those obtained from a primary system directly or indirectly. Nearly energy independent response was obtained in.the range 60 keV to 0,8 MeV with this secondary standard. Two solid state techniques namely thermoluminescence (TL) and thermally stimulated exoelectron emission (TSEE) were also used for beta dosimetry. Various characteristics like reproducibility, response with dose,energy dependence, etc. were studied for the materials: LiF, CaF 2 ,Li 2 B 4 O 7 , Be O, CaSO 4 and Al 2 O 3 . TL detectors of thickness 0,9 mm underestimate the dose 60 μm thick CaSO 4 :Tm embedded on a thin aluminium plate gave energy independent response behind skin layers of 7 mg/cm 2 . Mixed field of beta, X and gamma radiation was analysed using this detector. Quartz based Be O and graphite based alpha beta-Al 2 O 3 were found to be good beta radiation detectors when the TSEE technique is used. Energy independent CaSO 4 :Tm TL dosimeters were used in international comparison for dose measurements and the results obtained were in agreement with the actual given doses within 10%. The TL detectors were also used for dose rate measurements from glazed painted tiles used in construction industry and a 85 Kr source used in textile and metal industries. Results obtained in the later case were Q compared with those using the secondary standard facility. (author)

  8. Developing an optimum protocol for thermoluminescence dosimetry with gr-200 chips using Taguchi method

    International Nuclear Information System (INIS)

    Sadeghi, Maryam; Faghihi, Reza; Sina, Sedigheh

    2017-01-01

    Thermoluminescence dosimetry (TLD) is a powerful technique with wide applications in personal, environmental and clinical dosimetry. The optimum annealing, storage and reading protocols are very effective in accuracy of TLD response. The purpose of this study is to obtain an optimum protocol for GR-200; LiF: Mg, Cu, P, by optimizing the effective parameters, to increase the reliability of the TLD response using Taguchi method. Taguchi method has been used in this study for optimization of annealing, storage and reading protocols of the TLDs. A number of 108 GR-200 chips were divided into 27 groups, each containing four chips. The TLDs were exposed to three different doses, and stored, annealed and read out by different procedures as suggested by Taguchi Method. By comparing the signal-to-noise ratios the optimum dosimetry procedure was obtained. According to the results, the optimum values for annealing temperature (de.C), Annealing Time (s), Annealing to Exposure time (d), Exposure to Readout time (d), Pre-heat Temperature (de.C), Pre-heat Time (s), Heating Rate (de.C/s), Maximum Temperature of Readout (de.C), readout time (s) and Storage Temperature (de.C) are 240, 90, 1, 2, 50, 0, 15, 240, 13 and -20, respectively. Using the optimum protocol, an efficient glow curve with low residual signals can be achieved. Using optimum protocol obtained by Taguchi method, the dosimetry can be effectively performed with great accuracy. (authors)

  9. Biological dosimetry of ionizing radiation by chromosomal aberration analysis; Dosimetria biologica de las radiaciones ionizantes mediante el analisis de aberraciones cromosomicas

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez-Castano, S.; Silva, A.; Navlet, J.

    1990-07-01

    Biological dosimetry consists of estimating absorbed doses for people exposed to radiation by mean biological methods. Several indicators used are based in haematological, biochemical, and cytogenetic data, although nowadays without doubt, the cytogenetic method is considered to be the most reliable. In this case, the study ol chromosomal aberrations, normally dicentric chromosomes, in peripheral lymphocytes can be related to absorbed dose through an experimental calibration curve. An experimental dose-response curve, using dicentric chromosomes analysis, X-rays at 300 kVp, 114 rad/min and temperature 37 degree celsius has been produced. Experimental data is fitted to model Y ={alpha} + {beta}{sub 1}D + {beta}{sub 2}D 2 , where Y is the number of dicentrics per cell and D the dose. The curve is compared with those produced elsewhere. (Author) 14 refs.

  10. Techniques for radiation measurements: Micro-dosimetry and dosimetry

    International Nuclear Information System (INIS)

    Waker, A. J.

    2006-01-01

    Experimental Micro-dosimetry is concerned with the determination of radiation quality and how this can be specified in terms of the distribution of energy deposition arising from the interaction of a radiation field with a particular target site. This paper discusses various techniques that have been developed to measure radiation energy deposition over the three orders of magnitude of site-size; nano-meter, micrometer and millimetre, which radiation biology suggests is required to fully account for radiation quality. Inevitably, much of the discussion will concern the use of tissue-equivalent proportional counters and variants of this device, but other technologies that have been studied, or are under development, for their potential in experimental Micro-dosimetry are also covered. Through an examination of some of the quantities used in radiation metrology and dosimetry the natural link with Micro-dosimetric techniques will be shown and the particular benefits of using Micro-dosimetric methods for dosimetry illustrated. (authors)

  11. The Relevance of Chromosome Aberration Yields for Biological Dosimetry After Low-Level Occupational Irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Bauchinger, M.; Schmid, E.; Hug, O. [Gesellschaft fuer Strahlenforschung, Institut fuer Biologie, Neuherberg, Federal Republic of Germany (Germany); Strahlenbiologisches Institut der Universitaet Muenchen, Federal Republic of Germany (Germany)

    1971-06-15

    The usefulness of chromosome analysis for biological dosimetry has been tested in two groups of persons occupationally exposed to radiation: (I) in nurses employed in gynaecological radiology, exposed especially when handling radium inserts; and (II) in nuclear industry workers, all of which were exposed to external gamma irradiation and some of them also to internal radiation after incorporation of various radionuclides. The total dose registered with personal dosimeters ranged in Group 1 from 0.1 to 91.1 rem accumulated over working periods of 0.1 to 13 years, and in Group II from 1.0 to 18.2 rem accumulated over 1 to 9 years. Compared with unexposed controls, both groups exhibit a significant increase of cells with chromosome aberrations as well as larger numbers of breaks per cell. Dicentrics and rings could be observed in some cells, providing good evidence for previous radiation exposure, since these types of aberrations are extremely rare events in unexposed individuals. No correlation between the aberration yields and the film badge values could be demonstrated in Group II. Also, in Group I the fluctuations from individual to individual are rather high. Nevertheless, a positive correlation to the ''dose'' was obtained. Even a sub-group of the nurses that had only been exposed to 20 rem showed significantly more aberrations than control persons. From the results obtained, type and frequency of chromosome aberrations may be considered an indicator of radiation exposure even at the low doses. The reasons for lack of correspondence of chromosome aberration yields and the results of personal monitoring procedures are discussed in detail. (author)

  12. Analysis of the DS86 atomic bomb radiation dosimetry methods using data on severe epilation

    International Nuclear Information System (INIS)

    Stram, D.O.; Mizuno, S.

    1989-01-01

    This report presents a reanalysis of the Hiroshima and Nagasaki data on severe epilation as an acute radiation effect using both the new DS86 and the old T65D dosimetries. The focus of the report is on several aspects of the data which have previously been examined by Jablon et al. The report examines the uniformity of epilation response across shielding category, across sex and age, and in terms of interactions between city, sex, age, and shielding category; it also investigates the apparent relative biological effectiveness (RBE) of neutrons in the DS86 dose compared with the T65D dose, using both within- and between-city information. In addition the report discusses evidence for nonlinearity in epilation response. The epilation response function exhibits nonlinearity in terms of both a marked increase in slope at about 0.75 Gy, and then, beginning at about 2.5 Gy, a leveling off and eventual decrease in response. The principal conclusions of the report are as follows. The use of the DS86 dosimetry rather than T65D increases the apparent RBE of neutrons compared with gamma dose from approximately 5 to 10. At these values of RBE the slope of the dose response, in a middle range from 0.75-2.5 Gy, is about 165% greater using DS86 than T65D. With respect to the interactions of sex, city, and shielding method, the size and significance of virtually all nonuniformities in epilation response seem using T65D are also evident with DS86. Additionally it seems difficult to find any evidence that DS86 is an improved predictor of epilation response over T65D. Finally, the fact that the nonlinearity in dose response and apparent actual downturn in epilation occurrence rate at the high end of dose is more striking with DS86 than with T65D is found to be due primarily to the common practice of truncating all T65D doses to 600 rad

  13. Dicentric chromosome aberration analysis using giemsa and centromere specific fluorescence in-situ hybridization for biological dosimetry: An inter- and intra-laboratory comparison in Indian laboratories

    International Nuclear Information System (INIS)

    Bhavani, M.; Tamizh Selvan, G.; Kaur, Harpreet; Adhikari, J.S.; Vijayalakshmi, J.; Venkatachalam, P.; Chaudhury, N.K.

    2014-01-01

    To facilitate efficient handling of large samples, an attempt towards networking of laboratories in India for biological dosimetry was carried out. Human peripheral blood samples were exposed to 60 Co γ-radiation for ten different doses (0–5 Gy) at a dose rate of 0.7 and 2 Gy/min. The chromosomal aberrations (CA) were scored in Giemsa-stained and fluorescence in-situ hybridization with centromere-specific probes. No significant difference (p>0.05) was observed in the CA yield for given doses except 4 and 5 Gy, between the laboratories, among the scorers and also staining methods adapted suggest the reliability and validates the inter-lab comparisons exercise for triage applications. - Highlights: • This is the first report from India on Networking for Biological Dosimetry preparedness using dicentric chromosomal (DC) aberration assay. • There is no significant difference in the in vitro dose response curve (Slope, Intercept, Curvature) constructed among the two labs. • No significant variation in the scoring of DC aberrations between the scorers irrespective of labs. • The DC results obtained by the labs from the Giemsa stained metaphase preparations were confirmed with centromere specific-FISH for further reliability and validity

  14. Improvement of Accuracy in Environmental Dosimetry by TLD Cards Using Three-dimensional Calibration Method

    Directory of Open Access Journals (Sweden)

    HosseiniAliabadi S. J.

    2015-06-01

    Full Text Available Background: The angular dependency of response for TLD cards may cause deviation from its true value on the results of environmental dosimetry, since TLDs may be exposed to radiation at different angles of incidence from the surrounding area. Objective: A 3D setting of TLD cards has been calibrated isotropically in a standard radiation field to evaluate the improvement of the accuracy of measurement for environmental dosimetry. Method: Three personal TLD cards were rectangularly placed in a cylindrical holder, and calibrated using 1D and 3D calibration methods. Then, the dosimeter has been used simultaneously with a reference instrument in a real radiation field measuring the accumulated dose within a time interval. Result: The results show that the accuracy of measurement has been improved by 6.5% using 3D calibration factor in comparison with that of normal 1D calibration method. Conclusion: This system can be utilized in large scale environmental monitoring with a higher accuracy

  15. Collaborative Physical and Biological Dosimetry Studies for Neutron Capture Therapy at the RA-1 Research Reactor Facility

    Energy Technology Data Exchange (ETDEWEB)

    David W. Nigg; Amanda E. Schwint; John K. Hartwell; Elisa M. Heber; Veronica Trivillin; Jorge Castillo; Luis Wentzeis; Patrick Sloan; Charles A. Wemple

    2004-10-01

    Initial physical dosimetry measurements have been completed using activation spectrometry and thermoluminiscent dosimeters to characterize the BNCT irradiation facility developed at the RA-1 research reactor operated by the Argentine National Atomic Energy Commission in Buenos Aires. Some biological scoping irradiations have also been completed using a small-animal (hamster) oral mucosa tumor model. Results indicate that the RA-1 neutron source produces useful dose rates but that some improvements in the initial configuration will be needed to optimize the spectrum for thermal-neutron BNCT research applications.

  16. Collaborative Physical and Biological Dosimetry Studies for Neutron Capture Therapy at the RA-1 Research Reactor Facility

    Energy Technology Data Exchange (ETDEWEB)

    Nigg, D.W.; Schwint, A.E.; Hartwell, J.K.; Heber, E.M.; Trivillin, V.; Castillo, J.; Wentzeis, L.; Sloan, P.; Wemple, C.A.

    2004-10-04

    Initial physical dosimetry measurements have been completed using activation spectrometry and thermoluminiscent dosimeters to characterize the BNCT irradiation facility developed at the RA-1 research reactor operated by the Argentine National Atomic Energy Commission in Buenos Aires. Some biological scoping irradiations have also been completed using a small-animal (hamster) oral mucosa tumor model. Results indicate that the RA-1 neutron source produces useful dose rates but that some improvements in the initial configuration will be needed to optimize the spectrum for thermal-neutron BNCT research applications.

  17. Activities developed by the biological dosimetry laboratory of the Autoridad Regulatoria Nuclear - ARN of Argentina; Actividades desarrolladas por el laboratorio de dosimetria biologica de la Autoridad Regulatoria Nuclear de Argentina

    Energy Technology Data Exchange (ETDEWEB)

    Radl, A.; Sapienza, C. E.; Taja, M. R.; Bubniak, R.; Deminge, M.; Di Giorgio, M., E-mail: csapienza@arn.gob.ar [Autoridad Regulatoria Nuclear (ARN), Buenos Aires (Argentina)

    2013-07-01

    Biological dosimetry (DB) allows to estimate doses absorbed in individuals exposed to ionizing radiation through the quantification of stable and unstable chromosome aberrations (SCA and UCA). The frequency of these aberrations is referred to a calibration dose response curve (in vitro) to determine the doses of the individual to the whole body. The DB is a necessary support for programs of national radiation protection and response systems in nuclear or radiological emergencies in the event of accidental or incidental, single overexposure or large scale. In this context the Laboratory of Dosimetry Biological (LDB) of the Authority Regulatory Nuclear (ARN) Argentina develops and applies different dosimeters cytogenetic from four decades ago. These dosimeters provide a fact more within the whole of the information necessary for an accidental, complementing the physical and clinical dosimetry exposure assessment. The most widely used in the DB biodosimetric method is the quantification of SCA (dicentrics and rings Central) from a sample of venous blood. The LDB is accredited for the trial, under rules IRAM 301: 2005 (ISO / IEC 17025: 2005) and ISO 19238:2004. Test applies to the immediate dosimetry evaluation of acute exposures, all or a large part of the body in the range 0,1-5 Gy. In this context the LDB is part of the Latin American network of DB (LBDNet), BioDoseNet-who and response system in radiological emergencies and nuclear IAEA-RANET, being enabled to summon the LBDNet if necessary.

  18. 10 CFR 835.1304 - Nuclear accident dosimetry.

    Science.gov (United States)

    2010-01-01

    ...) Methods and equipment for analysis of biological materials; (3) A system of fixed nuclear accident... Nuclear accident dosimetry. (a) Installations possessing sufficient quantities of fissile material to... 10 Energy 4 2010-01-01 2010-01-01 false Nuclear accident dosimetry. 835.1304 Section 835.1304...

  19. Evaluation of the efficiency of different methods of personal dosimetry in vascular interventional radiology

    International Nuclear Information System (INIS)

    Bacchim Neto, F.A.; Alves, A.F.F.; Rosa, M.E.D.; Pina, D.R.

    2017-01-01

    Interventional Radiology - IR is the area of medicine that provides the largest occupational exposures. The dose values to which interventionists are exposed are difficult to standardize. The objective of the study is to perform a complete evaluation of occupational exposures and to determine the efficiency of different personal dosimetry methods used in IR. We evaluated the efficiencies of 6 different personal dosimetry methodologies used internationally to estimate the effective dose received by interventional professionals. And, based on this analysis, determine the characteristics of each methodology. One of the methods of personal dosimetry recommended by Brazilian legislation was the most conservative, overestimating, on average, the effective dose of professionals by up to 200%, reaching maximum values close to 400%. The most accurate method was that used in North America. This method did not overestimate the effective dose of the professionals more than a few percent and their standard deviation relative to the effective reference dose were the lowest. Based on these results, the choice of methodologies employing at least two dosimeters, one under and above protective aprons is recommended. In addition, in some situations where the dose in the hands may be high, additional dosimeters for this region are also recommended

  20. Developing an Optimum Protocol for Thermoluminescence Dosimetry with GR-200 Chips using Taguchi Method.

    Science.gov (United States)

    Sadeghi, Maryam; Faghihi, Reza; Sina, Sedigheh

    2017-06-15

    Thermoluminescence dosimetry (TLD) is a powerful technique with wide applications in personal, environmental and clinical dosimetry. The optimum annealing, storage and reading protocols are very effective in accuracy of TLD response. The purpose of this study is to obtain an optimum protocol for GR-200; LiF: Mg, Cu, P, by optimizing the effective parameters, to increase the reliability of the TLD response using Taguchi method. Taguchi method has been used in this study for optimization of annealing, storage and reading protocols of the TLDs. A number of 108 GR-200 chips were divided into 27 groups, each containing four chips. The TLDs were exposed to three different doses, and stored, annealed and read out by different procedures as suggested by Taguchi Method. By comparing the signal-to-noise ratios the optimum dosimetry procedure was obtained. According to the results, the optimum values for annealing temperature (°C), Annealing Time (s), Annealing to Exposure time (d), Exposure to Readout time (d), Pre-heat Temperature (°C), Pre-heat Time (s), Heating Rate (°C/s), Maximum Temperature of Readout (°C), readout time (s) and Storage Temperature (°C) are 240, 90, 1, 2, 50, 0, 15, 240, 13 and -20, respectively. Using the optimum protocol, an efficient glow curve with low residual signals can be achieved. Using optimum protocol obtained by Taguchi method, the dosimetry can be effectively performed with great accuracy. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  1. A new method for dosimetry with films radiochromic; Un nuevo metodo para la dosimetria con peliculas radiocromica

    Energy Technology Data Exchange (ETDEWEB)

    Mendez Carot, I.

    2013-07-01

    in this paper a new method is presented and the results of the comparison between the calibration is summarized based on a planning reference and calibration obtained from the irradiated fragments measure different dose levels multichannel compare dosimetry based on the weighted average dosimetry described by Micke et al.(present in the FilmQAPro software) and, finally, show different results obtained with the method proposed in several applications clinics. (Author)

  2. Validation of an immunochemical assay for the detection of DNA damage as a tool for biological dosimetry of human exposure to ionizing radiation

    International Nuclear Information System (INIS)

    Schans, G.P. van der; Timmerman, A.J.; Wojewodzka, M.; Zaim, J.

    1997-01-01

    A method for biological dosimetry based on the immunochemical detection of DNA damage in human white blood cells has been validated. To this end the method developed at TNO (Rijswijk, the Netherlands) was also set up at INCT (Warsaw, Poland). Blood samples of 11 individuals were irradiated with 0 or 5 Gy of 170 kV X-rays at INCT and analyzed both at INCT and TNO. It appeared that in both laboratories damage could be detected to the same extent. The average background level of DNA damage amounted to 1.0 Gy-eq with an interindividual standard deviation of 0.25 Gy. The contribution of the sample variance to the total variance is only 14%. The radiosensitivity showed only a variation of about 10% and can, therefore, be neglected in estimating the radiation dose from the amount of DNA damage detected. (author)

  3. Basic study on electrically stimulated luminescence (ESL) as a dosimetry and dating method

    International Nuclear Information System (INIS)

    Sato, H.; Yamanaka, C.; Ikeya, M.

    2003-01-01

    Electrically stimulated luminescence (ESL) of calcium carbonate has been studied for application as dosimetry and dating. A powdered calcium carbonate was sandwiched by electrodes, which supplied electric field. Luminescence and surface current through a powdered sample were measured using a photomultiplier and a digital multimeter, respectively. A linear dependence of ESL on the absorbed dose by γ-rays was found when the applied voltage was below the breakdown threshold. Reciprocal electric charges through the sample had also linear relation with the absorbed dose. We propose that the luminescence and electric charge under intense electric field in calcium carbonate become new methods for dosimetry and dating on the basis of the surface defects of the calcium carbonate grains produced by the irradiation of γ-rays

  4. Dosimetry; La dosimetrie

    Energy Technology Data Exchange (ETDEWEB)

    Le Couteulx, I.; Apretna, D.; Beaugerie, M.F. [Electricite de France (EDF), 75 - Paris (France)] [and others

    2003-07-01

    Eight articles treat the dosimetry. Two articles evaluate the radiation doses in specific cases, dosimetry of patients in radiodiagnosis, three articles are devoted to detectors (neutrons and x and gamma radiations) and a computer code to build up the dosimetry of an accident due to an external exposure. (N.C.)

  5. Extension of the biological effective dose to the MIRD schema and possible implications in radionuclide therapy dosimetry

    International Nuclear Information System (INIS)

    Baechler, Sebastien; Hobbs, Robert F.; Prideaux, Andrew R.; Wahl, Richard L.; Sgouros, George

    2008-01-01

    In dosimetry-based treatment planning protocols, patients with rapid clearance of the radiopharmaceutical require a larger amount of initial activity than those with slow clearance to match the absorbed dose to the critical organ. As a result, the dose-rate to the critical organ is higher in patients with rapid clearance and may cause unexpected toxicity compared to patients with slow clearance. In order to account for the biological impact of different dose-rates, radiobiological modeling is beginning to be applied to the analysis of radionuclide therapy patient data. To date, the formalism used for these analyses is based on kinetics derived from activity in a single organ, the target. This does not include the influence of other source organs to the dose and dose-rate to the target organ. As a result, only self-dose irradiation in the target organ contributes to the dose-rate. In this work, the biological effective dose (BED) formalism has been extended to include the effect of multiple source organ contributions to the net dose-rate in a target organ. The generalized BED derivation has been based on the Medical Internal Radionuclide Dose Committee (MIRD) schema assuming multiple source organs following exponential effective clearance of the radionuclide. A BED-based approach to determine the largest safe dose to critical organs has also been developed. The extended BED formalism is applied to red marrow dosimetry, as well as kidney dosimetry considering the cortex and the medulla separately, since both those organs are commonly dose limiting in radionuclide therapy. The analysis shows that because the red marrow is an early responding tissue (high α/β), it is less susceptible to unexpected toxicity arising from rapid clearance of high levels of administered activity in the marrow or in the remainder of the body. In kidney dosimetry, the study demonstrates a complex interplay between clearance of activity in the cortex and the medulla, as well as the initial

  6. Investigation of a pulsed current annealing method in reusing MOSFET dosimeters for in vivo IMRT dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Luo, Guang-Wen; Qi, Zhen-Yu, E-mail: qizhy@sysucc.org.cn; Deng, Xiao-Wu [Department of Radiation Oncology, Sun Yat-Sen University Cancer Center and State Key Laboratory of Oncology in Southern China, Collaborative Innovation Center of Cancer Medicine, Guangzhou 510060 (China); Rosenfeld, Anatoly [Centre for Medical Radiation Physics, University of Wollongong, Wollongong, NSW 2522 (Australia)

    2014-05-15

    Purpose: To explore the feasibility of pulsed current annealing in reusing metal oxide semiconductor field-effect transistor (MOSFET) dosimeters forin vivo intensity modulated radiation therapy (IMRT) dosimetry. Methods: Several MOSFETs were irradiated atd{sub max} using a 6 MV x-ray beam with 5 V on the gate and annealed with zero bias at room temperature. The percentage recovery of threshold voltage shift during multiple irradiation-annealing cycles was evaluated. Key dosimetry characteristics of the annealed MOSFET such as the dosimeter's sensitivity, reproducibility, dose linearity, and linearity of response within the dynamic range were investigated. The initial results of using the annealed MOSFETs for IMRT dosimetry practice were also presented. Results: More than 95% of threshold voltage shift can be recovered after 24-pulse current continuous annealing in 16 min. The mean sensitivity degradation was found to be 1.28%, ranging from 1.17% to 1.52%, during multiple annealing procedures. Other important characteristics of the annealed MOSFET remained nearly consistent before and after annealing. Our results showed there was no statistically significant difference between the annealed MOSFETs and their control samples in absolute dose measurements for IMRT QA (p = 0.99). The MOSFET measurements agreed with the ion chamber results on an average of 0.16% ± 0.64%. Conclusions: Pulsed current annealing provides a practical option for reusing MOSFETs to extend their operational lifetime. The current annealing circuit can be integrated into the reader, making the annealing procedure fully automatic.

  7. Investigation of a pulsed current annealing method in reusing MOSFET dosimeters for in vivo IMRT dosimetry

    International Nuclear Information System (INIS)

    Luo, Guang-Wen; Qi, Zhen-Yu; Deng, Xiao-Wu; Rosenfeld, Anatoly

    2014-01-01

    Purpose: To explore the feasibility of pulsed current annealing in reusing metal oxide semiconductor field-effect transistor (MOSFET) dosimeters forin vivo intensity modulated radiation therapy (IMRT) dosimetry. Methods: Several MOSFETs were irradiated atd max using a 6 MV x-ray beam with 5 V on the gate and annealed with zero bias at room temperature. The percentage recovery of threshold voltage shift during multiple irradiation-annealing cycles was evaluated. Key dosimetry characteristics of the annealed MOSFET such as the dosimeter's sensitivity, reproducibility, dose linearity, and linearity of response within the dynamic range were investigated. The initial results of using the annealed MOSFETs for IMRT dosimetry practice were also presented. Results: More than 95% of threshold voltage shift can be recovered after 24-pulse current continuous annealing in 16 min. The mean sensitivity degradation was found to be 1.28%, ranging from 1.17% to 1.52%, during multiple annealing procedures. Other important characteristics of the annealed MOSFET remained nearly consistent before and after annealing. Our results showed there was no statistically significant difference between the annealed MOSFETs and their control samples in absolute dose measurements for IMRT QA (p = 0.99). The MOSFET measurements agreed with the ion chamber results on an average of 0.16% ± 0.64%. Conclusions: Pulsed current annealing provides a practical option for reusing MOSFETs to extend their operational lifetime. The current annealing circuit can be integrated into the reader, making the annealing procedure fully automatic

  8. A simple method of dosimetry for E-beam radiation

    International Nuclear Information System (INIS)

    Spencer, D.S.; Thalacker, V.P.; Chasman, J.N.; Siegel, S.

    1985-01-01

    A simple method utilizing a photochromic 'intensity label' for monitoring electron-beam sources was evaluated. The labels exhibit a color change upon exposure to UV or e-beam radiation. A correlation was found between absorbed energy and Gardner Color Index at low electron-beam doses. (author)

  9. Dosimetry methods for the estimation of exposure to ionizing radiation

    International Nuclear Information System (INIS)

    Lopez Bejarano, Gladys

    2012-01-01

    Ionizing radiations, by their nature, have required for their detection the use of suitable devices generically referred detecting systems. The detection of secondary particles arising during the processes of ionization and excitation to the passage of radiation in the environment, have constituted the basis of the measurement methods. A detector system is a device that converts the energy of the incident radiation on a signal (electrical, photochemical, etc.) that is easily processable from the technological point of view, but without distorting the original information. These devices have provided qualitative or quantitative information about the radiation of interest. The detector system is a set of a detector together with a processing system. This system has based its operation in methods of: gas ionization, scintillation, semiconductor, film, thermoluminescence, among others. (author) [es

  10. A Radiation Dosimetry Method Using Pulsed Optically Stimulated Luminescence

    International Nuclear Information System (INIS)

    Akselrod, M.S.; McKeever, S.W.S.

    1999-01-01

    A method for the determination of absorbed radiation dose is described based on pulsed optically stimulated luminescence (POSL). The method relies upon the stimulation of an irradiated sample with a train of light pulses from a suitable light source (e.g. a laser) using a wavelength which is within the range of wavelengths corresponding to the radiation-induced optical absorption in the irradiated sample. The subsequent emitted light, due to the detrapping of trapped charges and their subsequent recombination with charge of the opposite sign, is synchronously detected in the period between each stimulation pulse. The total luminescence is summed over the desired number of stimulation pulses and this forms the measured POSL signal. By monitoring the emitted light only in the period between stimulation pulses one can reduce the optical filtering required to discriminate between the stimulation light and the emission light; in this way a high measurement efficiency, and, therefore, a high radiation sensitivity (luminescence intensity per unit absorbed dose) is achieved. Key parameters in the method are the intrinsic luminescence lifetime for the material being used as the luminescent detector, the width of the optical stimulation pulse, and the period between pulses. For optimum operation the measurement parameters should be such that both the pulse width and the time between pulses are much less than the luminescence lifetime. By appropriate choice of the power of the optical stimulation, the frequency of the stimulation pulses, and the total stimulation period, one can also re-measure the absorbed dose several times. In this way, a re-read capability is available with the procedure. The method is illustrated using light from a 2nd-harmonic Nd:YAG laser, with irradiated, anion-deficient aluminium oxide as the luminescent detector material. (author)

  11. Modern methods to improve the accuracy in fast neutron dosimetry

    International Nuclear Information System (INIS)

    Baers, B.; Karnani, H.; Seren, T.

    1985-01-01

    In order to improve the quality of fast neutron dose estimates at the reactor pressure vessel (PV) some modern methods are presented. In addition to basic principles, some error reduction procedures are also presented based on the combined use of relative measurements, direct sample taking from the pressure vessel and the use of iron and niobium as dosimeters. The influence of large systematic errors could be significantly reduced by carrying out relative measurements. This report also presents the successful use of niobium as a dosimeter by destructive treatment of PV samples. (author)

  12. Bayesian methods for chromosome dosimetry following a criticality accident

    International Nuclear Information System (INIS)

    Brame, R.S.; Groer, P.G.

    2003-01-01

    Radiation doses received during a criticality accident will be from a combination of fission spectrum neutrons and gamma rays. It is desirable to estimate the total dose, as well as the neutron and gamma doses. Present methods for dose estimation with chromosome aberrations after a criticality accident use point estimates of the neutron to gamma dose ratio obtained from personnel dosemeters and/or accident reconstruction calculations. In this paper a Bayesian approach to dose estimation with chromosome aberrations is developed that allows the uncertainty of the dose ratio to be considered. Posterior probability densities for the total and the neutron and gamma doses were derived. (author)

  13. Determination of factors through Monte Carlo method for Fricke dosimetry from 192Ir sources for brachytherapy

    International Nuclear Information System (INIS)

    David, Mariano Gazineu; Salata, Camila; Almeida, Carlos Eduardo

    2014-01-01

    The Laboratorio de Ciencias Radiologicas develops a methodology for the determination of the absorbed dose to water by Fricke chemical dosimetry method for brachytherapy sources of 192 Ir high dose rate and have compared their results with the laboratory of the National Research Council Canada. This paper describes the determination of the correction factors by Monte Carlo method, with the Penelope code. Values for all factors are presented, with a maximum difference of 0.22% for their determination by an alternative way. (author)

  14. Biological dosimetry of patients with differenced carcinoma of thyroid treated with Iodine-131; Dosimetria biologica de pacientes con carcinoma diferenciado de tiroides tratados con Iodo-131

    Energy Technology Data Exchange (ETDEWEB)

    Vallerga, M. B.; Rojo, A.M.; Taja, M.R.; Deluca, G.; Di Giorgio, M. [Autoridad Regulatoria Nuclear Av. Del Libertador 8250 (C1429BNP). Buenos Aires (Argentina); Fadel, A. [Hospital General de Agudos Dr. Carlos Durand Av. Diaz Velez 5044. Buenos Aires (Argentina); Cabrejas, M.; Valdivieso, C. [Hospital de Clfnicas Jose de San Martin Av. Cordoba 2351 (CP1120). Buenos Aires (Argentina)]. e-mail: mvallerg@cae.arn.gov.ar

    2006-07-01

    aberrations it was considered absorbed dose to whole body. The obtained doses were compared by the different biological methods used. The evaluation by internal dosimetry of the data obtained tracer post-activity allowed to personalize the activity of I-131 to administer, starting from physical-mathematical models that consider the particular biokinetics of each patient (MIRD methodology). The doses estimated by the used biological dosemeters were consistent among them. It was discussed its scopes and limitations to be applied in the validation of the dosimetric estimation based on models, in order to administer a therapeutic dose protecting the patient of the adverse effects of the internal radiotherapy in organs that are not target of the same one. The acquired experience is considered of utility to give answer in cases of radioiodine incorporation in occupationally exposed personnel. (Author)

  15. Advances in a framework to compare bio-dosimetry methods for triage in large-scale radiation events

    International Nuclear Information System (INIS)

    Flood, Ann Barry; Boyle, Holly K.; Du, Gaixin; Demidenko, Eugene; Williams, Benjamin B.; Swartz, Harold M.; Nicolalde, Roberto J.

    2014-01-01

    Planning and preparation for a large-scale nuclear event would be advanced by assessing the applicability of potentially available bio-dosimetry methods. Using an updated comparative framework the performance of six bio-dosimetry methods was compared for five different population sizes (100-1 000 000) and two rates for initiating processing of the marker (15 or 15 000 people per hour) with four additional time windows. These updated factors are extrinsic to the bio-dosimetry methods themselves but have direct effects on each method's ability to begin processing individuals and the size of the population that can be accommodated. The results indicate that increased population size, along with severely compromised infrastructure, increases the time needed to triage, which decreases the usefulness of many time intensive dosimetry methods. This framework and model for evaluating bio-dosimetry provides important information for policy-makers and response planners to facilitate evaluation of each method and should advance coordination of these methods into effective triage plans. (authors)

  16. Biological and clinical dosimetry. Progress report July 1, 1964-June 30, 1979

    International Nuclear Information System (INIS)

    Laughlin, J.S.; McDonald, J.C.

    1979-01-01

    The dosimetric studies at this laboratory were initiated with the primary goal of developing systems for the determination of absorbed dose in biological research and clinical applications. The primary method under study is the local absorbed dose calorimeter, a concept initiated and developed by J. S. Laughlin. In addition, secondary dosimetric systems such as ionization chambers, chemical dosimeters and thermoluminescent dosimeters (TLD) are being developed and applied to provide an absolute basis for the evaluation and comparison of experiments, treatments, and other procedures using radiation

  17. Clinical dosimetry

    International Nuclear Information System (INIS)

    Rassow, J.

    1973-01-01

    The main point of this paper on clinical dosimetry which is to be understood here as application of physical dosimetry on accelerators in medical practice, is based on dosimetric methodics. Following an explanation of the dose parameters and description of the dose distribution important for clinical practice as well as geometric irradiation parameters, the significance of a series of physical parameters such as accelerator energy, surface energy of average stopping power etc. is dealt with in detail. Following a section on field homogenization with bremsstrahlung and electron radiation, details on dosimetry in clinical practice are given. Finally, a few problems of dosemeter or monitor calibration on accelerators are described. The explanations are supplemented by a series of diagrams and tables. (ORU/LH) [de

  18. A Quality Assurance Method that Utilizes 3D Dosimetry and Facilitates Clinical Interpretation

    Energy Technology Data Exchange (ETDEWEB)

    Oldham, Mark, E-mail: mark.oldham@duke.edu [Radiation Oncology, Duke University Medical Center, Durham, North Carolina (United States); Thomas, Andrew; O' Daniel, Jennifer; Juang, Titania [Radiation Oncology, Duke University Medical Center, Durham, North Carolina (United States); Ibbott, Geoffrey [University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Adamovics, John [Rider University, Lawrenceville, New Jersey (United States); Kirkpatrick, John P. [Radiation Oncology, Duke University Medical Center, Durham, North Carolina (United States)

    2012-10-01

    Purpose: To demonstrate a new three-dimensional (3D) quality assurance (QA) method that provides comprehensive dosimetry verification and facilitates evaluation of the clinical significance of QA data acquired in a phantom. Also to apply the method to investigate the dosimetric efficacy of base-of-skull (BOS) intensity-modulated radiotherapy (IMRT) treatment. Methods and Materials: Two types of IMRT QA verification plans were created for 6 patients who received BOS IMRT. The first plan enabled conventional 2D planar IMRT QA using the Varian portal dosimetry system. The second plan enabled 3D verification using an anthropomorphic head phantom. In the latter, the 3D dose distribution was measured using the DLOS/Presage dosimetry system (DLOS = Duke Large-field-of-view Optical-CT System, Presage Heuris Pharma, Skillman, NJ), which yielded isotropic 2-mm data throughout the treated volume. In a novel step, measured 3D dose distributions were transformed back to the patient's CT to enable calculation of dose-volume histograms (DVH) and dose overlays. Measured and planned patient DVHs were compared to investigate clinical significance. Results: Close agreement between measured and calculated dose distributions was observed for all 6 cases. For gamma criteria of 3%, 2 mm, the mean passing rate for portal dosimetry was 96.8% (range, 92.0%-98.9%), compared to 94.9% (range, 90.1%-98.9%) for 3D. There was no clear correlation between 2D and 3D passing rates. Planned and measured dose distributions were evaluated on the patient's anatomy, using DVH and dose overlays. Minor deviations were detected, and the clinical significance of these are presented and discussed. Conclusions: Two advantages accrue to the methods presented here. First, treatment accuracy is evaluated throughout the whole treated volume, yielding comprehensive verification. Second, the clinical significance of any deviations can be assessed through the generation of DVH curves and dose overlays on

  19. Optical fiber detectors as in-vivo dosimetry method of quality assurance in radiation therapy

    International Nuclear Information System (INIS)

    Plazas, M.C.; Justus, B.L.; Falkenstein, P.; Huston, A.L.; Ning, H.; Miller, R.

    2004-01-01

    A new in-vivo dosimetry system has been under development for some time using radio luminescent phosphors. These phosphors are activated, metal ion doped glasses (Ex: Cu 1± doped quartz fiber), have excellent optical transparency and offer several potential advantages for radiation dosimetry; including: small size, high sensitivity, linearity of dose response insensitivity to electromagnetic interference. The utility of these phosphors as a detection modality has been limited in real-time dosimetry applications due to the production of Cerenkov radiation in the carrier fiber, which produces a contaminant signal proportional to dose rate as well as the size of the radiation field. One possible method for eliminating this signal is using an electronic gating signal from the accelerator to delay data acquisition during the actual beam pulse, when Cerenkov radiation is produced. Due to the intrinsic properties of our particular scintillator, this method offers the best mechanism for eliminating Cerenkov noise, while retaining the ability to detect individual beam pulses. The dosimeter was tested using an external beam radiotherapy machine that provided pulses of 6 MeV x-rays. Gated detection was used to discriminate the signal collected during the radiation pulses, which included contributions from Cerenkov radiation and native fiber fluorescence, from the signal collected between the radiation pulses, which contained only the long-lived phosphorescence from the Cu 1± doped fused quartz detector. Gated detection of the phosphorescence provided accurate, real-time dose measurements that were linear with absorbed dose, independent of dose rate and that were accurate for all field sizes studied. (author)

  20. A method to improve application technique in Alanine/ESR dosimetry

    International Nuclear Information System (INIS)

    Choi, Hoon; Ha, Ju Hee; Choi, Won; Lim, Young Khi

    2008-01-01

    Full text: For long-term radiation monitoring to assess the cable aging in harsh condition of nuclear power plant, ESR dosimetry method using alanine dosimeters was already recommended in many technical document and paper. Several ESR dosimetry systems were already produced and used widely, but the actual application of these systems for industrial dosimetry needs careful consideration of error sources in process of dose measurement. The alanine dosimeters were measured by E-scan alanine analyzer system or EMX ESR spectrometer. For the accurate measurement of the dosimeters, we have studied various source of errors. First, this paper discusses sources of inaccuracy related to data processing. To make a meaningful dose assessment, the dosimeter measurements need to be compared with measurements made using certified dosimeters of known dose. This is achieved by performing the routine calibration procedure which creates a calibration curve and corresponding fit coefficients from measurements made with a set of dosimeters with known certified dose. The calibration curves in ESR dosimetry are usually constructed by means of the least-squares technique in its simplest variant. The recommended alternative linearity several replicate measurements of Y at each used X value. Also, measurement is subject to error, so repeat measurements will not be identical. A technical description of a linear calibration is assumed that the dispersion of the measurements is the same for each standard. But in some cases, the standard deviation has to be specified separately for each value of concentration. In this case, it used the WLS (Weighted Least-Squared Regression) method instead of the OLS (Ordinary Least-Squared Regression) method. Second, the precision of the ESR spectrum was showed as a reproducibility test for the two ESR systems. The reproducibility test was performed at an absorbed dose of 1 k Gy, which is at least three orders of magnitude above the background reading of an

  1. Holographic method coupled with an optoelectronic interface applied in the ionizing radiation dosimetry

    International Nuclear Information System (INIS)

    Nicolau-Rebigan, S.; Sporea, D.; Niculescu, V.I.R.

    2000-01-01

    The paper presents a holographic method applied in the ionizing radiation dosimetry. It is possible to use two types of holographic interferometry like as double exposure holographic interferometry, or fast real time holographic interferometry. In this paper the applications of holographic interferometry to ionizing radiation dosimetry are presented. The determination of the accurate value of dose delivered by an ionizing radiation source (released energy per mass unit) is a complex problem which imposes different solutions depending on experimental parameters and it is solved with a double exposure holographic interferometric method associated with an optoelectronic interface and Z80 microprocessor. The method can determine the absorbed integral dose as well as the three-dimensional distribution of dose in given volume. The paper presents some results obtained in radiation dosimetry. Original mathematical relations for integral absorbed dose in irreversible radiolyzing liquids where derived. Irradiation effects can be estimated from the holographic fringes displacement and density. To measure these parameters, the obtained holographic interferograms were picked-up by a closed TV circuit system in such a way that a selected TV line explores the picture along the direction of interest using a special designed interface, a Z80 and our microprocessor system captures data along the selected TV line. When the integral dose is to be measured the microprocessor computes it from the information contained in the fringes distribution, according to the proposed formulae. Integral absorbed dose and spatial dose distribution can be estimated with an accuracy better than 4%. Some advantages of this method are outlined comparatively with conventional method in radiation dosimetry. The paper presents an original holographic set-up with an electronic interface, assisted by a Z80 microprocessor and used for nondestructive testing of transparent objects at the laser wave length

  2. AN EXACT GOODNESS-OF-FIT TEST BASED ON THE OCCUPANCY PROBLEMS TO STUDY ZERO-INFLATION AND ZERO-DEFLATION IN BIOLOGICAL DOSIMETRY DATA.

    Science.gov (United States)

    Fernández-Fontelo, Amanda; Puig, Pedro; Ainsbury, Elizabeth A; Higueras, Manuel

    2018-01-12

    The goal in biological dosimetry is to estimate the dose of radiation that a suspected irradiated individual has received. For that, the analysis of aberrations (most commonly dicentric chromosome aberrations) in scored cells is performed and dose response calibration curves are built. In whole body irradiation (WBI) with X- and gamma-rays, the number of aberrations in samples is properly described by the Poisson distribution, although in partial body irradiation (PBI) the excess of zeros provided by the non-irradiated cells leads, for instance, to the Zero-Inflated Poisson distribution. Different methods are used to analyse the dosimetry data taking into account the distribution of the sample. In order to test the Poisson distribution against the Zero-Inflated Poisson distribution, several asymptotic and exact methods have been proposed which are focused on the dispersion of the data. In this work, we suggest an exact test for the Poisson distribution focused on the zero-inflation of the data developed by Rao and Chakravarti (Some small sample tests of significance for a Poisson distribution. Biometrics 1956; 12 : 264-82.), derived from the problems of occupancy. An approximation based on the standard Normal distribution is proposed in those cases where the computation of the exact test can be tedious. A Monte Carlo Simulation study was performed in order to estimate empirical confidence levels and powers of the exact test and other tests proposed in the literature. Different examples of applications based on in vitro data and also data recorded in several radiation accidents are presented and discussed. A Shiny application which computes the exact test and other interesting goodness-of-fit tests for the Poisson distribution is presented in order to provide them to all interested researchers. © The Author(s) 2018. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  3. Infants and young children modeling method for numerical dosimetry studies: application to plane wave exposure

    International Nuclear Information System (INIS)

    Dahdouh, S; Wiart, J; Bloch, I; Varsier, N; Nunez Ochoa, M A; Peyman, A

    2016-01-01

    Numerical dosimetry studies require the development of accurate numerical 3D models of the human body. This paper proposes a novel method for building 3D heterogeneous young children models combining results obtained from a semi-automatic multi-organ segmentation algorithm and an anatomy deformation method. The data consist of 3D magnetic resonance images, which are first segmented to obtain a set of initial tissues. A deformation procedure guided by the segmentation results is then developed in order to obtain five young children models ranging from the age of 5 to 37 months. By constraining the deformation of an older child model toward a younger one using segmentation results, we assure the anatomical realism of the models. Using the proposed framework, five models, containing thirteen tissues, are built. Three of these models are used in a prospective dosimetry study to analyze young child exposure to radiofrequency electromagnetic fields. The results lean to show the existence of a relationship between age and whole body exposure. The results also highlight the necessity to specifically study and develop measurements of child tissues dielectric properties. (paper)

  4. Use of computational methods for substitution and numerical dosimetry of real bones

    International Nuclear Information System (INIS)

    Silva, I.C.S.; Gonzalez, K.M.L.; Barbosa, A.J.A.; Lucindo Junior, C.R.; Vieira, J.W.; Lima, F.R.A.

    2017-01-01

    Estimating the dose that ionizing radiation deposits in the soft tissues of the skeleton within the cavities of the trabecular bones represents one of the greatest difficulties faced by numerical dosimetry. The Numerical Dosimetry Group (GDN/CNPq) Brazil, Recife-PE has used a method based on micro-CT images. The problem of the implementation of micro-CT is the difficulty in obtaining samples of real bones (OR). The objective of this work was to evaluate the sample of a virtual block of trabecular bone through the nonparametric method based on the voxel frequencies (VF) and samples of the climbing plant called Luffa aegyptica, whose dry fruit is known as vegetal bush (BV) substitution of OR samples. For this, a theoretical study of the two techniques developed by the GDN was made. The study showed in both techniques, after the dosimetric evaluations, that the actual sample can be replaced by the synthetic samples, since they have shown dose estimates close to the actual one

  5. Infants and young children modeling method for numerical dosimetry studies: application to plane wave exposure

    Science.gov (United States)

    Dahdouh, S.; Varsier, N.; Nunez Ochoa, M. A.; Wiart, J.; Peyman, A.; Bloch, I.

    2016-02-01

    Numerical dosimetry studies require the development of accurate numerical 3D models of the human body. This paper proposes a novel method for building 3D heterogeneous young children models combining results obtained from a semi-automatic multi-organ segmentation algorithm and an anatomy deformation method. The data consist of 3D magnetic resonance images, which are first segmented to obtain a set of initial tissues. A deformation procedure guided by the segmentation results is then developed in order to obtain five young children models ranging from the age of 5 to 37 months. By constraining the deformation of an older child model toward a younger one using segmentation results, we assure the anatomical realism of the models. Using the proposed framework, five models, containing thirteen tissues, are built. Three of these models are used in a prospective dosimetry study to analyze young child exposure to radiofrequency electromagnetic fields. The results lean to show the existence of a relationship between age and whole body exposure. The results also highlight the necessity to specifically study and develop measurements of child tissues dielectric properties.

  6. Comparison of two methods of quantitation in human studies of biodistribution and radiation dosimetry

    International Nuclear Information System (INIS)

    Smith, T.

    1992-01-01

    A simple method of quantitating organ radioactivity content for dosimetry purposes based on relationships between organ count rate and the initial whole body count rate, has been compared with a more rigorous method of absolute quantitation using a transmission scanning technique. Comparisons were on the basis of organ uptake (% administered activity) and resultant organ radiation doses (mGy MBq -1 ) in 6 normal male volunteers given a 99 Tc m -labelled myocardial perfusion imaging agent intravenously at rest and following exercise. In these studies, estimates of individual organ uptakes by the simple method were in error by between +24 and -16% compared with the more accurate method. However, errors on organ dose values were somewhat less and the effective dose was correct to within 3%. (Author)

  7. Applications, dosimetry and biological interactions of static and time-varying magnetic fields

    International Nuclear Information System (INIS)

    Tenforde, T.S.

    1988-08-01

    The primary topics of this presentation include: (1) the applications of magnetic fields in research, industry, and medical technologies; (2) mechanisms of interaction of static and time-varying magnetic fields with living systems; (3) human health effects of exposure to static and time-varying magnetic fields in occupational, medical, and residential settings; and (4) recent advances in the dosimetry of extremely-low-frequency electromagnetic fields. The discussion of these topics is centered about two issues of considerable contemporary interest: (1) potential health effects of the fields used in magnetic resonance imaging and in vivo spectroscopy, and (2) the controversial issue of whether exposure to extremely-low-frequency (ELF) electromagnetic fields in the home and workplace leads to an elevated risk of cancer. 11 refs

  8. Mathematical methods in biology and neurobiology

    CERN Document Server

    Jost, Jürgen

    2014-01-01

    Mathematical models can be used to meet many of the challenges and opportunities offered by modern biology. The description of biological phenomena requires a range of mathematical theories. This is the case particularly for the emerging field of systems biology. Mathematical Methods in Biology and Neurobiology introduces and develops these mathematical structures and methods in a systematic manner. It studies:   • discrete structures and graph theory • stochastic processes • dynamical systems and partial differential equations • optimization and the calculus of variations.   The biological applications range from molecular to evolutionary and ecological levels, for example:   • cellular reaction kinetics and gene regulation • biological pattern formation and chemotaxis • the biophysics and dynamics of neurons • the coding of information in neuronal systems • phylogenetic tree reconstruction • branching processes and population genetics • optimal resource allocation • sexual recombi...

  9. Environmental dosimetry

    International Nuclear Information System (INIS)

    Gold, R.

    1977-01-01

    For more than 60 years, natural radiation has offered broad opportunities for basic research as evidenced by many fundamental discoveries. Within the last decade, however, dramatic changes have occurred in the motivation and direction of this research. The urgent need for economical energy sources entailing acceptably low levels of environmental impact has compelled the applied aspects of our radiation environment to become overriding considerations. It is within this general framework that state-of-the-art environmental dosimetry techniques are reviewed. Although applied motivation and relevance underscores the current milieu for both reactor and environmental dosimetry, a perhaps even more unifying force is the broad similarity of reactor and environmental radiation fields. In this review, a comparison of these two mixed radiation fields is presented stressing the underlying similarities that exist. On this basis, the evolution of a strong inner bond between dosimetry methods for both reactor and environmental radiation fields is described. The existence of this bond will be illustrated using representative examples of observed spectra. Dosimetry methods of particularly high applicability for both of these fields are described. Special emphasis is placed on techniques of high sensitivity and absolute accuracy which are capable of resolving the components of these mixed radiation fields

  10. Microautoradiographic methods and their applications in biology

    International Nuclear Information System (INIS)

    Benes, L.

    1978-01-01

    A survey of microautoradiographic methods and of their application in biology is given. The current state of biological microautoradiography is shown, focusing on the efficiency of techniques and on special problems proceeding in autoradiographic investigations in biology. Four more or less independent fields of autoradiography are considered. In describing autoradiographic techniques two methodological tasks are emphasized: The further development of the labelling technique in all metabolic studies and of instrumentation and automation of autoradiograph evaluation. (author)

  11. Dosimetry of ionizing radiation

    International Nuclear Information System (INIS)

    Musilek, L.; Seda, J.; Trousil, J.

    1992-01-01

    The publication deals with a major field of ionizing radiation dosimetry, viz., integrating dosimetric methods, which are the basic means of operative dose determination. It is divided into the following sections: physical and chemical effects of ionizing radiation; integrating dosimetric methods for low radiation doses (film dosimetry, nuclear emulsions, thermoluminescence, radiophotoluminescence, solid-state track detectors, integrating ionization dosemeters); dosimetry of high ionizing radiation doses (chemical dosimetric methods, dosemeters based on the coloring effect, activation detectors); additional methods applicable to integrating dosimetry (exoelectron emission, electron spin resonance, lyoluminescence, etc.); and calibration techniques for dosimetric instrumentation. (Z.S.). 422 refs

  12. Methods for plant molecular biology

    National Research Council Canada - National Science Library

    Weissbach, Arthur; Weissbach, Herbert

    1988-01-01

    .... Current techniques to carry out plant cell culture and protoplast formation are described as are methods for gene and organelle transfer. The detection of DNA and RNA viruses by molecular probes or ELISA assays and the cloning and transcription of viral RNA complete the volume.

  13. MIRD Commentary: Proposed Name for a Dosimetry Unit Applicable to Deterministic Biological Effects-The Barendsen (Bd)

    International Nuclear Information System (INIS)

    Sgouros, George; Howell, R. W.; Bolch, Wesley E.; Fisher, Darrell R.

    2009-01-01

    The fundamental physical quantity for relating all biologic effects to radiation exposure is the absorbed dose, the energy imparted per unit mass of tissue. Absorbed dose is expressed in units of joules per kilogram (J/kg) and is given the special name gray (Gy). Exposure to ionizing radiation may cause both deterministic and stochastic biologic effects. To account for the relative effect per unit absorbed dose that has been observed for different types of radiation, the International Commission on Radiological Protection (ICRP) has established radiation weighting factors for stochastic effects. The product of absorbed dose in Gy and the radiation weighting factor is defined as the equivalent dose. Equivalent dose values are designated by a special named unit, the sievert (Sv). Unlike the situation for stochastic effects, no well-defined formalism and associated special named quantities have been widely adopted for deterministic effects. The therapeutic application of radionuclides and, specifically, -particle emitters in nuclear medicine has brought to the forefront the need for a well-defined dosimetry formalism applicable to deterministic effects that is accompanied by corresponding special named quantities. This commentary reviews recent proposals related to this issue and concludes with a recommendation to establish a new named quantity

  14. Dating by fission track method: study of neutron dosimetry with natural uranium thin films

    International Nuclear Information System (INIS)

    Iunes, P.J.

    1990-06-01

    Fission track dating is described, focalizing the problem of the decay constant for spontaneous fission of 238 U and the use of neutron dosimetry in fission track analysis. Experimental procedures using thin films of natural uranium as neutron dosimeters and its results are presented. The author shows a intercomparison between different thin films and between the dosimetry with thin film and other dosimetries. (M.V.M.). 52 refs, 12 figs, 9 tabs

  15. Use of Biological Methods in Criminology

    OpenAIRE

    Müllerová, Nikola

    2014-01-01

    Criminology is a science dealing with the protection of citizens and state from infringement. Criminology uses mostly biological or genetic methods for crime detection. Forensic traces which are collected by forensic experts on the scene are the key items of those methods. Forensic genetics is among the most important forensic subdisciplines. Forensic genetics uses DNA analysis for identification. The main aims of this study are description and importance of biological, anthropological and ge...

  16. Dosimetry of internal emitters

    International Nuclear Information System (INIS)

    Anon.

    1982-01-01

    The Dosimetry of Internal Emitter Program endeavors to refine the correlation between radiation dose and observed biological effects. The program is presently engaged in the development of studies that will demonstrate the applicability of microdosimetry models developed under the Microdosimetry of Internal Sources Program. The program also provides guidance and assistance to Pacific Northwest Laboratory's Biology Department in the dosimetric analysis of internally deposited radionuclides. This report deals with alpha particle dosimetry plutonium 239 inhalation, and in vitro studies of chromosomal observations

  17. Contribution of new cytogenetic techniques in the estimations of old irradiations in retrospective biological dosimetry

    International Nuclear Information System (INIS)

    Pouzoulet, F.

    2007-10-01

    The objective of this study was to answer three questions: if the translocations are steady: the results have shown that the translocations even if they are not obligatory steady can be used in retrospective dosimetry. Furthermore, it appeared important to consider the complex translocations in view of their relative stability and complementary information they bring ( quality of radiation, received dose). The second question is what contribution of the M-F.I.S.H. in the translocations analysis in comparison with the F.I.S.H.-3: we have shown that the M-F.I.S.H. would allow to raise the whole of doubt due to a partial genome observation. that has for effect to increase the precision of the analysis and that what ever be the received dose. The third question is if there are differences between the chromosomal aberrations generated by x radiation of 50 keV and by gamma radiation from cobalt-60: yes, the low energy photons generate more translocations than the photons coming from cobalt-60. But they generate less dicentrics. this difference comes from the way the energy is deposited that leads to a more important formation of complex and multiple translocations with the low energy photons. this could constitute a problem in the use of low energy photons in radiotherapy. it would seem that the simple translocations rate is not influenced by the photons energy. (N.C.)

  18. Comparing personal alpha dosimetry with the conventional area monitoring-time weighting methods of exposure estimation: a Canadian assessment

    International Nuclear Information System (INIS)

    Balint, A.B.; Viljoen, J.

    1988-01-01

    An experimental personal alpha dosimetry program for monitoring exposures of uranium mining facility workers in Canada has been completed. All licenced operating mining facilities were participating. Dosimetry techniques, description of dosimeters used by licences, performance and problems associated with the implementation of the programme as well as technical and administrative advantages and difficulties experienced are discussed. Area monitoring-time weighting methods used and results obtained to determine individual radon and thoron daughter exposure and exposure results generated by using dosimeters are assessed and compared

  19. Assessment of radiation damage - the need for a multi-parametric and integrative approach with the help of both clinical and biological dosimetry

    International Nuclear Information System (INIS)

    Meineke, Viktor

    2008-01-01

    Full text: Accidental exposure to ionising radiation leads to a damage on different levels of the biological organization of the organism. Depending on exposure conditions, such as nature of radiation, time and affected organs and organ systems, the clinical endpoint of radiation damage and the resulting acute and chronic radiation syndromes may vary to a great extent. Exposure situations range from pure localised radiation scenarios and partial body exposures up to whole body exposures. Therefore clinical pictures vary from localized radiation injuries up to the extreme situation of a radiation-induced multi-organ involvement and failure requiring immediate, intensive and interdisciplinary medical treatment. These total different and complex clinical situations not only show up most different clinical diagnostic and therapeutic aspects but necessarily due to different levels of the underlying biological damage, biological indicators of effects may vary to a wide extent. This fact means that an exact assessment of the extent of radiation damage within individual patients can only be performed when taking into consideration both clinical signs and symptoms as well as different biological indicators. Among the clinical indicators, routine laboratory parameters such as blood counts and the documentation of clinical signs and symptoms (such as the METREPOL system) are the key parameters, whereas the dicentric assay, the gold standard for biological dosimetry, but also methods under development such as the gamma-H2Ax focus assay or the estimation of variations of gene expression have to be taken into account. Each method provides best results in different situations, or in other words, there are methods that work better in a specific exposure condition or at a given time of examination (e.g. time after exposure) than others. Some methods show up results immediately, others require days to weeks until results are available for clinical decision making. Therefore to

  20. Simple Calculation Programs for Biology Immunological Methods

    Indian Academy of Sciences (India)

    First page Back Continue Last page Overview Graphics. Simple Calculation Programs for Biology Immunological Methods. Computation of Ab/Ag Concentration from EISA data. Graphical Method; Raghava et al., 1992, J. Immuno. Methods 153: 263. Determination of affinity of Monoclonal Antibody. Using non-competitive ...

  1. On the use of thin natural uranium film dosimetry in mineral dating by the fission track method

    International Nuclear Information System (INIS)

    Hadler Neto, J.C.; Iunes, P.J.; Khouri, M.C.

    1993-01-01

    Three obsidian samples were irradiated in a neutron facility and their age was measured by the fission track method; using a thin uranium film dosemeter. The results were compared to others made previously on the same type of rock using conventional neutron dosimetry. The use of thin uranium film for age determination is discussed. (F.E.). 20 refs, 4 tabs

  2. A method for automating calibration and records management for instrumentation and dosimetry

    International Nuclear Information System (INIS)

    O'Brien, J.M. Jr.; Rushton, R.O.; Burns, R.E. Jr.

    1993-01-01

    Current industry requirements are becoming more stringent on quality assurance records and documentation for calibration of instruments and dosimetry. A novel method is presented here that will allow a progressive automation scheme to be used in pursuit of that goal. This concept is based on computer-controlled irradiators that can act as stand-alone devices or be interfaced to other components via a computer local area network. In this way, complete systems can be built with modules to create a records management system to meet the needs of small laboratories or large multi-building calibration groups. Different database engines or formats can be used simply by replacing a module. Modules for temperature and pressure monitoring or shipping and receiving can be added, as well as equipment modules for direct IEEE-488 interface to electrometers and other instrumentation

  3. Use of hydroxyapatite prepared by sol-gel method for gamma ray and electron beam dosimetry

    International Nuclear Information System (INIS)

    Hajiloo, N.; Ziaie, F.; Hesami, M.

    2011-01-01

    In this research, radiation dosimetry was made through measuring free radicals induced in synthetic hydroxyapatite using EPR spectroscopy. At the first step, the hydroxyapatite nano-powders were synthesized via sol-gel method. The produced powders were passed through a thermal treatment, weighted and packed. Then, the samples were irradiated at different dose rates using 60 Co γ-ray and 10 MeV electron beam radiation at a high dose range. The hydroxyapatite signal intensity of hydroxyapatite samples were measured at room temperature in the air. Subsequently, the variations of the EPR signal intensities were constructed as peak-to-peak signal amplitude and were compared with alanine and bone powder samples. The results showed that the EPR signal intensity of the hydroxyapatite samples are several times higher than alanine and bone powder and are saturated at the higher dose rates in comparison with other species.

  4. EPR dosimetry teeth in past and future accidents: A prospective look at a retrospective method

    Energy Technology Data Exchange (ETDEWEB)

    Haskell, E.; Kenner, G.; Hayes, R. [Univ. of Utah, Salt Lake City, UT (United States). Center for Applied Dosimetry; Chumak, V.; Shalom, S. [Scientific Center for Radiation Medicine, Kiev (Ukraine)

    1997-03-01

    Accurate assessments of doses received by individuals exposed to radiation from nuclear accidents and incidents such as those at Hiroshima and Nagasaki, the Nevada test site, Cheliabinsk and Mayak are required for epidemiological studies seeking to establish relationships between radiation dose and health effects. One method of retrospective dosimetry which allows for measurement of cumulative gamma ray doses received by exposed individuals is electron paramagnetic resonance spectroscopy (EPR) of tooth enamel. Tooth enamel stores and retains, indefinitely, information on absorbed radiation dose. And teeth are available in every population as a result of dental extraction for medical reasons including periodontal disease and impacted wisdom teeth. In the case of children, deciduous teeth, which are shed between the ages of 7 and 13, can be a very important dosimetric source if documented collection is implemented shortly following an accident.

  5. A method for automating calibration and records management for instrumentation and dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    O`Brien, J.M. Jr.; Rushton, R.O.; Burns, R.E. Jr. [Atlan-Tech, Inc., Roswell, GA (United States)

    1993-12-31

    Current industry requirements are becoming more stringent on quality assurance records and documentation for calibration of instruments and dosimetry. A novel method is presented here that will allow a progressive automation scheme to be used in pursuit of that goal. This concept is based on computer-controlled irradiators that can act as stand-alone devices or be interfaced to other components via a computer local area network. In this way, complete systems can be built with modules to create a records management system to meet the needs of small laboratories or large multi-building calibration groups. Different database engines or formats can be used simply by replacing a module. Modules for temperature and pressure monitoring or shipping and receiving can be added, as well as equipment modules for direct IEEE-488 interface to electrometers and other instrumentation.

  6. EPR dosimetry teeth in past and future accidents: A prospective look at a retrospective method

    International Nuclear Information System (INIS)

    Haskell, E.; Kenner, G.; Hayes, R.

    1997-01-01

    Accurate assessments of doses received by individuals exposed to radiation from nuclear accidents and incidents such as those at Hiroshima and Nagasaki, the Nevada test site, Cheliabinsk and Mayak are required for epidemiological studies seeking to establish relationships between radiation dose and health effects. One method of retrospective dosimetry which allows for measurement of cumulative gamma ray doses received by exposed individuals is electron paramagnetic resonance spectroscopy (EPR) of tooth enamel. Tooth enamel stores and retains, indefinitely, information on absorbed radiation dose. And teeth are available in every population as a result of dental extraction for medical reasons including periodontal disease and impacted wisdom teeth. In the case of children, deciduous teeth, which are shed between the ages of 7 and 13, can be a very important dosimetric source if documented collection is implemented shortly following an accident

  7. Neutron spectrum determination of d(20)+Be source reaction by the dosimetry foils method

    Science.gov (United States)

    Stefanik, Milan; Bem, Pavel; Majerle, Mitja; Novak, Jan; Simeckova, Eva

    2017-11-01

    The cyclotron-based fast neutron generator with the thick beryllium target operated at the NPI Rez Fast Neutron Facility is primarily designed for the fast neutron production in the p+Be source reaction at 35 MeV. Besides the proton beam, the isochronous cyclotron U-120M at the NPI provides the deuterons in the energy range of 10-20 MeV. The experiments for neutron field investigation from the deuteron bombardment of thick beryllium target at 20 MeV were performed just recently. For the neutron spectrum measurement of the d(20)+Be source reaction, the dosimetry foils activation method was utilized. Neutron spectrum reconstruction from resulting reaction rates was performed using the SAND-II unfolding code and neutron cross-sections from the EAF-2010 nuclear data library. Obtained high-flux white neutron field from the d(20)+Be source is useful for the intensive irradiation experiments and cross-section data validation.

  8. EPR dosimetry of teeth in past and future accidents. A prospective look at a retrospective method

    Energy Technology Data Exchange (ETDEWEB)

    Haskell, E.; Kenner, G.; Hayes, R. [Center for Applied Dosimetry, Salt Lake City, UT (United States); Chumak, V.; Shalom, S.

    1996-12-31

    Accurate assessments of doses received by individuals exposed to radiation from nuclear accidents and incidents such as those at Hiroshima and Nagasaki, the Nevada test site, Chelyabinsk and Mayak are required for epidemiological studies seeking to establish relationships between radiation dose and health effects. One method of retrospective dosimetry which allows for measurement of cumulative gamma ray doses received by exposed individuals is electron paramagnetic resonance spectroscopy (EPR) of tooth enamel. Tooth enamel stores and retains, indefinitely, information on absorbed radiation dose; and teeth are available in every population as a result of dental extraction for medical reasons including periodontal disease and impacted wisdom teeth. In the case of children, deciduous teeth, which are shed between the ages of 7 and 13, can be a very important dosimetric source if documented collection is implemented shortly following an accident. (author)

  9. Thin film tritium dosimetry

    Science.gov (United States)

    Moran, Paul R.

    1976-01-01

    The present invention provides a method for tritium dosimetry. A dosimeter comprising a thin film of a material having relatively sensitive RITAC-RITAP dosimetry properties is exposed to radiation from tritium, and after the dosimeter has been removed from the source of the radiation, the low energy electron dose deposited in the thin film is determined by radiation-induced, thermally-activated polarization dosimetry techniques.

  10. Biologic data, models, and dosimetric methods for internal emitters

    International Nuclear Information System (INIS)

    Weber, D.A.

    1990-01-01

    The absorbed radiation dose from internal emitters has been and will remain a pivotal factor in assessing risk and therapeutic utility in selecting radiopharmaceuticals for diagnosis and treatment. Although direct measurements of absorbed dose and dose distributions in vivo have been and will continue to be made in limited situations, the measurement of the biodistribution and clearance of radiopharmaceuticals in human subjects and the use of this data is likely to remain the primary means to approach the calculation and estimation of absorbed dose from internal emitters over the next decade. Since several approximations are used in these schema to calculate dose, attention must be given to inspecting and improving the application of this dosimetric method as better techniques are developed to assay body activity and as more experience is gained in applying these schema to calculating absorbed dose. Discussion of the need for considering small scale dosimetry to calculate absorbed dose at the cellular level will be presented in this paper. Other topics include dose estimates for internal emitters, biologic data mathematical models and dosimetric methods employed. 44 refs

  11. In-situ fluorescence hybridization applied to biological dosimetry: contribution of automation to the counting of radio-induced chromosome aberrations

    International Nuclear Information System (INIS)

    Germain Thomas Roy, Laurence

    1999-01-01

    The frequency of chromosome aberrations on peripheral blood lymphocytes is a dose indicator in the case of ionizing radiations over-exposure. Stable chromosome aberrations (translocations, insertions) are visualized after labelling of some chromosomes using the fluorescence in-situ hybridization (FISH). The study of the use of the FISH technique in biological dosimetry is done with dose-effect curves. It seems that a bias is introduced during the observation of chromosome aberrations involving only 3 pairs of chromosomes. In order to avoid this bias, it would be useful to test the feasibility of using the multi-FISH technique in biological dosimetry. Moreover, this type of chromosome aberration changes with the type of irradiation. It is thus important to define the aberrations to be considered when the FISH technique is used. In order to reduce the time of image analysis, the CYTOGEN system, developed by IMSTAR company (Paris, France) has been adapted to the needs of biological dosimetry. This system allows to localize automatically the metaphases on the slide, which reduces the observation time by 2 or 4. An automatic detection protocol for chromosome aberrations has been implemented. It comprises the image capture, the contours detection and the classification of some chromosome aberrations. The different steps of this protocol have been tested in order to check that no bias is introduced by the automation. However, because radio-induced aberrations are rare events, it seems that a totally automatic system is not foreseeable. A semi-automatic analysis is more suitable. The use of the Slit-Scan technology (Laboratory of applied physics, Heidelberg, Germany) in biological dosimetry has been studied too. This technique allows to analyze rapidly a huge number of chromosomes. A good correlation has been observed between the dicentric frequency measured automatically and by manual counting. The system is under development and should be adapted to the detection of

  12. Radiochromic film dosimetry

    International Nuclear Information System (INIS)

    Xu Zhiyong

    2002-01-01

    Radiochromic film dosimetry was developed to measure ionization irradiation dose for industry and medicine. At this time, there are no comprehensive guideline on the medical application, calibration method and densitometer system for medicine. The review gives update on Radiochromic film dosimetry used for medicine, including principles, film model and material, characteristics, calibration method, scanning densitometer system and medical application

  13. Activities of Project 'Cooperation and development with Latin America and Iberian in Biological Dosimetry of Iberian Group of Radiation Protection Societies

    International Nuclear Information System (INIS)

    Nasazzi, Nora B.; Taja, Maria R.; Giorgio, Marina di; Garcia Lima, Omar; Lamadrid, Ana I.; Olivares, Pilar; Moreno, Mercedes; Prieto, Maria J.; Espinosa, Marco

    2001-01-01

    In 1996 the GRIAPRA Group (Latin American and Iberian Group of Radiation Protection Societies) was established with the participation of Argentina, Brazil, Cuba, Mexico, Peru, Portugal and Spain. In 1998 began the biennial Collaborative Working Project 'Cooperation and Development with Latin America in Biological Dosimetry', partially supported by the Extremadura Government, Spain, initially involving five countries: Argentina, Cuba, Peru, Portugal and Spain. The general aim of the project is to create an Latin American and Iberian Biological Dosimetry Laboratories Coordinated Group in order to: give mutual cooperation and to other countries if required, in the case of radiological accident; contribute to enhance the technical capabilities of the participant laboratories; promote the installment of laboratories on this field in countries that does not have it yet through the training of human resources and providing the necessary equipment and, finally, perform jointly research activities in biological dosimetry. The activities designed in order to accomplish the project specific aims for the 1998-2000 period have been achieved. Description and results are presented. (author)

  14. Simple Calculation Programs for Biology Other Methods

    Indian Academy of Sciences (India)

    First page Back Continue Last page Overview Graphics. Simple Calculation Programs for Biology Other Methods. Hemolytic potency of drugs. Raghava et al., (1994) Biotechniques 17: 1148. FPMAP: methods for classification and identification of microorganisms 16SrRNA. graphical display of restriction and fragment map of ...

  15. Thermoluminescence in medical dosimetry

    International Nuclear Information System (INIS)

    Rivera, T.

    2011-10-01

    The dosimetry by thermoluminescence (Tl) is applied in the entire world for the dosimetry of ionizing radiations specially to personal and medical dosimetry. This dosimetry method has been very interesting for measures in vivo because the Tl dosimeters have the advantage of being very sensitive in a very small volume and they are also equivalent to tissue and they do not need additional accessories (for example, cable, electrometer, etc.) The main characteristics of the diverse Tl materials to be used in the radiation measures and practical applications are: the Tl curve, the share homogeneity, the signal stability after the irradiation, precision and exactitude, the response in function with the dose and the energy influence. In this work a brief summary of the advances of the radiations dosimetry is presented by means of the thermally stimulated luminescence and its application to the dosimetry in radiotherapy. (Author)

  16. Reshaping of computational system for dosimetry in neutron and photons radiotherapy based in stochastic methods - SISCODES

    International Nuclear Information System (INIS)

    Trindade, Bruno Machado

    2011-02-01

    This work shows the remodeling of the Computer System for Dosimetry of Neutrons and Photons in Radiotherapy Based on Stochastic Methods . SISCODES. The initial description and status, the alterations and expansions (proposed and concluded), and the latest system development status are shown. The SISCODES is a system that allows the execution of a 3D computational planning in radiation therapy, based on MCNP5 nuclear particle transport code. The SISCODES provides tools to build a patient's voxels model, to define a treatment planning, to simulate this planning, and to view the results of the simulation. The SISCODES implements a database of tissues, sources and nuclear data and an interface to access then. The graphical SISCODES modules were rewritten or were implemented using C++ language and GTKmm library. Studies about dose deviations were performed simulating a homogeneous water phantom as analogue of the human body in radiotherapy planning and a heterogeneous voxel phantom, pointing out possible dose miscalculations. The Soft-RT and PROPLAN computer codes that do interface with SISCODES are described. A set of voxels models created on the SISCODES are presented with its respective sizes and resolutions. To demonstrate the use of SISCODES, examples of radiation therapy and dosimetry simulations for prostate and heart are shown. Three protocols were simulated on the heart voxel model: Sm-153 filled balloon and P-32 stent, to prevent angioplasty restenosis; and Tl-201 myocardial perfusion, to imaging. Teletherapy with 6MV and 15MV beams were simulated to the prostate, and brachytherapy with I-125 seeds. The results of these simulations are shown on isodose curves and on dose-volume histograms. The SISCODES shows to be a useful tool for research of new radiation therapy treatments and, in future, can also be useful in medical practice. At the end, future improvements are proposed. I hope this work can contribute to develop more effective radiation therapy

  17. The Utility of Lymphocyte Premature Chromosome Condensation Analysis for Biological Dosimetry Following Accidental Overexposure to Ionising Radiation

    International Nuclear Information System (INIS)

    Chambrette, V.; Laval, F.; Voisin, P.

    1999-01-01

    Premature chromosome condensation (PCC) appears to have a possible utility for biological dosimetry purposes. The PCC technique may be adapted for cases of suspicion of overexposure where sampling is performed at least one day after an accident. For this purpose, human blood samples were exposed in vitro to 60 Co (0.5 Gy.min -1 ) up to 4 Gy and the PCC technique was performed after 24 h, 48 h, and 72 h of DNA repair at 37 deg. C. Analysis of excess PCC fragments distribution showed an overdispersion and the dose-effect relationship was best characterised by linear regression. Radiation-induced damage was reduced to 32% between the first and the second day of repair and to 42% the following day. Statistical precision of the dose was found to be dependent on the irradiation dose and on the number of cells examined. The necessity to establish dose-response relationships after different periods of DNA repair is demonstrated, and the use of PCC excess fragments yield as a bioindicator should take this fact into account. (author)

  18. Synthesis, biological distribution and radiation dosimetry of Te-123m analogues of hexadecenoic acid

    International Nuclear Information System (INIS)

    Basmadjian, G.P.; Ice, R.D.; Mills, S.L.

    1982-01-01

    The synthesis and biological distribution of four Te-123m analogues of hexadecenoic acid in rats, rabbits and dogs were described for use as possible myocardial imaging agents. The heart-to-blood ratios ranged from 0.13 for 3-telluranonadecenoic acid in rats at 5 mins to 6.25 for 18-methyl-17-tellura-9-nonadecenoic acid in dogs at 24 hrs. The biological half-life of the Te-123m labelled fatty acids ranged from 26 to 583 hrs in the hearts of the test animals. These Te-123m fatty acids were retained in the heart longer than radioiodinated fatty acids and have acceptable absorbed doses to the various target organs. (U.K.)

  19. Suitability of the echo-time-shift method as laboratory standard for thermal ultrasound dosimetry

    Science.gov (United States)

    Fuhrmann, Tina; Georg, Olga; Haller, Julian; Jenderka, Klaus-Vitold

    2017-03-01

    Ultrasound therapy is a promising, non-invasive application with potential to significantly improve cancer therapies like surgery, viro- or immunotherapy. This therapy needs faster, cheaper and more easy-to-handle quality assurance tools for therapy devices as well as possibilities to verify treatment plans and for dosimetry. This limits comparability and safety of treatments. Accurate spatial and temporal temperature maps could be used to overcome these shortcomings. In this contribution first results of suitability and accuracy investigations of the echo-time-shift method for two-dimensional temperature mapping during and after sonication are presented. The analysis methods used to calculate time-shifts were a discrete frame-to-frame and a discrete frame-to-base-frame algorithm as well as a sigmoid fit for temperature calculation. In the future accuracy could be significantly enhanced by using continuous methods for time-shift calculation. Further improvements can be achieved by improving filtering algorithms and interpolation of sampled diagnostic ultrasound data. It might be a comparatively accurate, fast and affordable method for laboratory and clinical quality control.

  20. OEDIPE, a software for personalized Monte Carlo dosimetry and treatment planning optimization in nuclear medicine: absorbed dose and biologically effective dose considerations

    International Nuclear Information System (INIS)

    Petitguillaume, A.; Broggio, D.; Franck, D.; Desbree, A.; Bernardini, M.; Labriolle Vaylet, C. de

    2014-01-01

    For targeted radionuclide therapies, treatment planning usually consists of the administration of standard activities without accounting for the patient-specific activity distribution, pharmacokinetics and dosimetry to organs at risk. The OEDIPE software is a user-friendly interface which has an automation level suitable for performing personalized Monte Carlo 3D dosimetry for diagnostic and therapeutic radionuclide administrations. Mean absorbed doses to regions of interest (ROIs), isodose curves superimposed on a personalized anatomical model of the patient and dose-volume histograms can be extracted from the absorbed dose 3D distribution. Moreover, to account for the differences in radiosensitivity between tumoral and healthy tissues, additional functionalities have been implemented to calculate the 3D distribution of the biologically effective dose (BED), mean BEDs to ROIs, isoBED curves and BED-volume histograms along with the Equivalent Uniform Biologically Effective Dose (EUD) to ROIs. Finally, optimization tools are available for treatment planning optimization using either the absorbed dose or BED distributions. These tools enable one to calculate the maximal injectable activity which meets tolerance criteria to organs at risk for a chosen fractionation protocol. This paper describes the functionalities available in the latest version of the OEDIPE software to perform personalized Monte Carlo dosimetry and treatment planning optimization in targeted radionuclide therapies. (authors)

  1. Signal processing for radiation dosimetry using EPR in dental enamel: comparison of three methods

    International Nuclear Information System (INIS)

    Pass, B. Barry.; Shames, A.I. Alexander I.

    2000-01-01

    We are reporting an alternative method of extracting useful dose information from complex EPR spectra of dental enamel. Digital differentiation of the initial first derivative spectrum followed by filtering is used to clearly distinguish the radiation-induced signal from the native background signal. The peak-to-peak height of the resulting second derivative of the signal is then measured as an indication of absorbed dose. This method does not require preliminary elimination of the native background signal, and is not effected by any uncertainty in the determination of the background signal or by errors resulting from the subtraction of two signals of comparable magnitude. Ten enamel samples were irradiated with known doses in the range of 250-10 5 mGy. There was agreement for all the samples, within the typical experimental error of ±10% for EPR dosimetry in dental enamel, between the doses determined by two common techniques using native signal subtraction and the doses determined by the new second derivative method proposed here

  2. Radiation-induced damage analysed by luminescence methods in retrospective dosimetry and emergency response.

    Science.gov (United States)

    Woda, Clemens; Bassinet, Céline; Trompier, François; Bortolin, Emanuela; Della Monaca, Sara; Fattibene, Paola

    2009-01-01

    The increasing risk of a mass casualty scenario following a large scale radiological accident or attack necessitates the development of appropriate dosimetric tools for emergency response. Luminescence dosimetry has been reliably applied for dose reconstruction in contaminated settlements for several decades and recent research into new materials carried close to the human body opens the possibility of estimating individual doses for accident and emergency dosimetry using the same technique. This paper reviews the luminescence research into materials useful for accident dosimetry and applications in retrospective dosimetry. The properties of the materials are critically discussed with regard to the requirements for population triage. It is concluded that electronic components found within portable electronic devices, such as e.g. mobile phones, are at present the most promising material to function as a fortuitous dosimeter in an emergency response.

  3. Protocol for X-ray dosimetry and exposure arrangements employed in studies of late somatic effects in mammals

    International Nuclear Information System (INIS)

    Zoetelief, J.; Kogel, A.J. van der; Broerse, J.J.; Scarpa, G.; Dixon-Brown, A.

    1985-01-01

    A number of European laboratories studying the late effects of ionizing radiation in animals have established an effective cooperation within the European Late Effects Project Group (EULEP) since 1970. To facilitate the exchange of biological results several techniques, including quality control of the experimental animals, pathology and dosimetry, have to be standardized. The most important aspects of the procedures for X-irradiation and dosimetry of small animals are summarized. These include recommendations on irradiation conditions, dosimetry methods, characteristics of phantoms and factors affecting X-ray dosimetry. X-irradiation procedures employed by the participating institutes are described and the results of five X-ray dosimetry intercomparisons are reported. The introduction of a common dosimetry protocol has resulted in improvements in exposure arrangements and absolute dosimetry. (author)

  4. The biological response of plucked human hair to low-dose radiation: a measure of individual radiosensitivity and a technique for biological dosimetry

    International Nuclear Information System (INIS)

    Swain, D.

    1997-01-01

    It is often assumed that the effects of radiation are linear with dose and that high dose effects can be extrapolated to low dose levels. However, there are a variety of mechanisms which can alter the response at low doses. The most important of these relate to induced sensitivity or induced repair mechanisms. It is therefore important that this area is studied in more depth by looking at the molecular effects and damage to cells at low doses. It is well known that there are certain rare genetic syndromes which predispose individuals to cancer, e.g. ataxia telangiectasia. It is also probable that there is a large range of sensitivity in the natural variation of individuals to the risk of radiation-induced cancer. It is proposed that radiosensitivity is studied using stimulated lymphocytes from whole blood and the technique extended to look at the effects in cell cultures established from human hair. Radiation treatment of cell cultures established from plucked human hair has been previously advocated as a non-invasive technique for non-uniform biological dosimetry and it is proposed that these techniques are adapted to the use of hair to estimate individual radiosensitivity. The aim is to establish and optimize these techniques for culturing keratinocytes from plucked human hair follicles with a view to study biological markers for the subsequent assessment of radiosensitivity. Preliminary results are promising and suggest that the technique for culturing keratinocytes from hair presents a feasible approach. Results from this primary cell culture technique and results from the comparison of the micronuclei data obtained from the cell cultures and stimulated lymphocytes will be presented. (author)

  5. Cytogenetic chromosomal aberration dosimetry method after radiation accidents and prognostic significance of stereotypically appearing chromosomal aberrations after radiation exposure

    International Nuclear Information System (INIS)

    Bloennigen, K.A.

    1973-01-01

    The paper reports on a radiation accident involving an Iridium-192 rod of an activity of 7.8 Ci and a size of 2 x 2 x 2 mm 3 . The radiation source had remained in direct contact with the left hip and elbow of the examined person for a period of 45 minutes. On the points that had been directly exposed, physical values of 5,000 rad and 10,000 rad were measured while the whole-body dose was 100-200 rad and the gonad dose 300-400 rad. These values were confirmed by observations of the clinical course and haematological and andrological examinations. Chromosome analysis of lymphocytes produced values between 100 and 125 and thus a significant agreement with the values determined by physical methods. The findings suggest that the relatively simple and fast method of cytogenetic dosimetry provides a useful complementary method to physical dosimetry. (orig./AK) [de

  6. Cytogenetic biological dosimetry in radiological protection: chromosome aberration analysis in human lymphocyties

    International Nuclear Information System (INIS)

    Campos, I.M.A. de.

    1988-01-01

    The effects of ionizing radiation on chromosomes have been know for several decades and dose effect relationships are also fairly well established for several doses and dose rates. Apart from its biological significance, the interpretation of chromosome aberration frequency associated with human exposure to radiation plays an important role in dose assessment, particularly in cases where exposure is though to have occurred but no physical dose monitoring system was present. Based on the cytogenetic data obtained from seven cases of exposure to radiation the aberration frequency have been fitted to the quadratic function Y= αD + βD 2 as the dose response curves from literature. The dose equivalent estimate by frequency of chromosomic aberration found here was compared with 60 Co and 192 Ir already published curves obtained at almost similar dose rate together with some hematological data. (author) [pt

  7. Development and performance evaluation of a dynamic phantom for biological dosimetry of moving targets

    Science.gov (United States)

    Gemmel, A.; Bert, C.; Saito, N.; von Neubeck, C.; Iancu, G.; K-Weyrather, W.; Durante, M.; Rietzel, E.

    2010-06-01

    A dynamic phantom has been developed to allow for measurement of 3D cell survival distributions and the corresponding distributions of the RBE-weighted dose (RBED) in the presence of motion. The phantom consists of two 96-microwell plates holding Chinese hamster ovary cells inside a container filled with culture medium and is placed on a movable stage. Basic biological properties of the phantom were investigated without irradiation and after irradiation with a carbon ion beam, using both a stationary (reference) exposure and exposure during motion of the phantom perpendicular to the beam with beam tracking. There was no statistically significant difference between plating efficiency measured in the microwells with and without motion (0.75) and values reported in the literature. Mean differences between measured and calculated cell survival for these two irradiation modes were within ±5% of the target dose of 6 Gy (RBE).

  8. Development and performance evaluation of a dynamic phantom for biological dosimetry of moving targets

    Energy Technology Data Exchange (ETDEWEB)

    Gemmel, A; Bert, C; Saito, N; Von Neubeck, C; Iancu, G; K-Weyrather, W; Durante, M; Rietzel, E, E-mail: alexander.ag.gemmel@siemens.co [GSI Helmholtzzentrum fuer Schwerionenforschung, Planckstr 1, 64291 Darmstadt (Germany)

    2010-06-07

    A dynamic phantom has been developed to allow for measurement of 3D cell survival distributions and the corresponding distributions of the RBE-weighted dose (RBED) in the presence of motion. The phantom consists of two 96-microwell plates holding Chinese hamster ovary cells inside a container filled with culture medium and is placed on a movable stage. Basic biological properties of the phantom were investigated without irradiation and after irradiation with a carbon ion beam, using both a stationary (reference) exposure and exposure during motion of the phantom perpendicular to the beam with beam tracking. There was no statistically significant difference between plating efficiency measured in the microwells with and without motion (0.75) and values reported in the literature. Mean differences between measured and calculated cell survival for these two irradiation modes were within {+-}5% of the target dose of 6 Gy (RBE).

  9. Stopping powers for protons in materials of interest in dosimetry and in medical and biological applications

    International Nuclear Information System (INIS)

    Thwaites, D.I.

    1985-01-01

    Stopping powers are required for many radiation applications in medicine and biology. Their accuracy can be critical. Some published calculations for these situations have not included recent developments in stopping power theory or the body of work on deviations from additivity due to phase of chemical binding effects. These areas have recently been reviewed and mean excitation energies recommended for a range of materials of interest. Calculated stopping powers are presented for protons of 0.4 to 200 MeV taking the available information into account. The materials considered are Lucite, ICRU composition muscle and bone, A-150 plastic, a TE gas, acetylene and polystyrene and water and water vapour. With suitable corrections and suitable I values in the Bethe stopping power expression, accuracies of <2% can be achieved. (author)

  10. Analysis of the frequency of mutant T-helpers as a parameter for biological dosimetry

    International Nuclear Information System (INIS)

    Mel'nov, S.B.; Minenko, V.F.; Demidchik, E.P.

    1998-01-01

    It was made the attempt of quantitatively estimation of radiation damage by the frequency of mutant T-helpers, i.e. CD4+cells, depleted of T-cell receptor (TCR). The object of the study was lymphocytes of peripheral blood of children exposed to iodine radioisotopes therapy on medical indications. The examined group consisted of 36 patients 10 -21 years old, which were injected from 0,3 to 27,6 GBq of iodine 131. The time between exposition to iodine 131 and the investigation varied from 2 months to 3 years. The results gave evidence about the existence of direct relation between the frequency of mutant T-helpers and integrated dose. The character of the relation was described on the basis of mathematical processing. It was concluded that TCR-test can be used for restoration of the biological radiation dose

  11. A simple method to back-project isocenter dose of radiotherapy treatments using EPID transit dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Silveira, T.B.; Cerbaro, B.Q.; Rosa, L.A.R. da, E-mail: thiago.fisimed@gmail.com, E-mail: tbsilveira@inca.gov.br [Instituto de Radioproteção e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro - RJ (Brazil)

    2017-07-01

    The aim of this work was to implement a simple algorithm to evaluate isocenter dose in a phantom using the back-projected transmitted dose acquired using an Electronic Portal Imaging Device (EPID) available in a Varian Trilogy accelerator with two nominal 6 and 10 MV photon beams. This algorithm was developed in MATLAB language, to calibrate EPID measured dose in absolute dose, using a deconvolution process, and to incorporate all scattering and attenuation contributions due to photon interactions with phantom. Modeling process was simplified by using empirical curve adjustments to describe the contribution of scattering and attenuation effects. The implemented algorithm and method were validated employing 19 patient treatment plans with 104 clinical irradiation fields projected on the phantom used. Results for EPID absolute dose calibration by deconvolution have showed percent deviations lower than 1%. Final method validation presented average percent deviations between isocenter doses calculated by back-projection and isocenter doses determined with ionization chamber of 1,86% (SD of 1,00%) and -0,94% (SD of 0,61%) for 6 and 10 MV, respectively. Normalized field by field analysis showed deviations smaller than 2% for 89% of all data for 6 MV beams and 94% for 10 MV beams. It was concluded that the proposed algorithm possesses sufficient accuracy to be used for in vivo dosimetry, being sensitive to detect dose delivery errors bigger than 3-4% for conformal and intensity modulated radiation therapy techniques. (author)

  12. The future of new calculation concepts in dosimetry based on the Monte Carlo Methods; Avenir des nouveaux concepts des calculs dosimetriques bases sur les methodes de Monte Carlo

    Energy Technology Data Exchange (ETDEWEB)

    Makovicka, L.; Vasseur, A.; Sauget, M.; Martin, E.; Gschwind, R.; Henriet, J. [Universite de Franche-Comte, Equipe IRMA/ENISYS/FEMTO-ST, UMR6174 CNRS, 25 - Montbeliard (France); Vasseur, A.; Sauget, M.; Martin, E.; Gschwind, R.; Henriet, J.; Salomon, M. [Universite de Franche-Comte, Equipe AND/LIFC, 90 - Belfort (France)

    2009-01-15

    Monte Carlo codes, precise but slow, are very important tools in the vast majority of specialities connected to Radiation Physics, Radiation Protection and Dosimetry. A discussion about some other computing solutions is carried out; solutions not only based on the enhancement of computer power, or on the 'biasing'used for relative acceleration of these codes (in the case of photons), but on more efficient methods (A.N.N. - artificial neural network, C.B.R. - case-based reasoning - or other computer science techniques) already and successfully used for a long time in other scientific or industrial applications and not only Radiation Protection or Medical Dosimetry. (authors)

  13. Reproductive function and biological dosimetry prospective study of young thyroid differentiated cancer patients treated with I-131

    International Nuclear Information System (INIS)

    Di Giorgio, M.; Vallerga, M.B.; Taja, M.R.; Radl, A.; Chebel, Graciela; Fadel, Ana Maria; Gutierrez, Silvia; Normandi, Eduardo; Levalle, Oscar; Kundt, Miriam

    2011-01-01

    The administration of I-131 in the management of differentiated thyroid cancer (DTC) is a well established practice. As the spermatogonia is highly sensitive to radiation, large doses of internal radiation could result in adverse effects on reproductive function such as oligo/azoospermia and infertility. During spermiogenesis, mammalian chromatin undergoes replacement of nuclear histones by protamines, which yields a DNA sixfold more highly condensed in spermatozoa than in mitotic chromosomes. The structure of this highly packaged chromatin shows a low binding capacity for several fluorochromes and dyes such as chromomycin A3 (CMA3). The aim of this study is to assess the correlation between reproductive function (endocrine and exocrine testicular function, and levels of CMA3 stainability) and biological dosimetry in a prospective study of 4 young DTC patients treated with I-131. In this context, a background level of CMA3 binding in mature human sperm was established. It revealed a variable accessibility of CMA3 to the DNA that is dependant on packaging quality and thus, indicative of protamine deficiency. The identification of altered stainability suggests DNA damage as well as epigenetic effects, which may be indicators of male infertility. Transient impairment of spermatogenesis associated with an increase in FSH, an altered spermiogram and even azoospermia was observed after the administration of cumulative activities. Overall, testosterone levels were preserved, except in one case, which presented a drastically diminished value associated with an increase in LH level. As peripheral blood lymphocytes and spermatogonia have equivalent radiosensitivity (interphase death) we hypothesize that the knowledge of DNA damage recovery in peripheral lymphocytes could correlate with spermatogonia recovery and with FSH evolution. (authors)

  14. Reproductive function and biological dosimetry prospective study of young thyroid differentiated cancer patients treated with I-131

    International Nuclear Information System (INIS)

    Di Giorgio, Marina; Vallerga, Maria B.; Taja, Maria R.; Radl, Analia; Chebel, Graciela; Fadel, Ana M.; Gutierrez, Silvia; Normandi, Eduardo; Levalle, Oscar; Kundt, Miriam

    2008-01-01

    Full text: The administration of I-131 in the management of differentiated thyroid cancer (DTC) is a well established practice. As the spermatogonia is highly sensitive to radiation, large doses of internal radiation could result in adverse effects on reproductive function such as oligo/azoospermia and infertility. During spermiogenesis, mammalian chromatin undergoes replacement of nuclear histones by protamines, which yields a DNA sixfold more highly condensed in spermatozoa than in mitotic chromosomes. The structure of this highly packaged chromatin shows a low binding capacity for several fluoro chromes and dyes such as chromo mycin A 3 (CMA 3 ). The aim of this study is to assess the correlation between reproductive function (endocrine and exocrine testicular function, and levels of CMA 3 stainability) and biological dosimetry in a prospective study of 4 young DTC patients treated with I-131. In this context, a background level of CMA 3 binding in mature human sperm was established. It revealed a variable accessibility of CMA 3 to the DNA that is dependant on packaging quality and thus, indicative of protamine deficiency. The identification of altered stainability suggests DNA damage as well as epigenetic effects, which may be indicators of male infertility. Transient impairment of spermatogenesis associated with an increase in FSH, an altered spermiogram and even azoospermia was observed after the administration of cumulative activities. Overall, testosterone levels were preserved, except in one case, which presented a drastically diminished value associated with an increase in LH level. As peripheral blood lymphocytes and spermatogonia have equivalent radiosensitivity (interphase death) we hypothesize that the knowledge of DNA damage recovery in peripheral lymphocytes could correlate with spermatogonia recovery and with FSH evolution. Therefore, a prospective study on the decline of unstable chromosome aberrations is being conducted, considering the damage

  15. Accreditation of a system of extremity dosimetry: validation and uncertainty of method; Acreditacion de un sistema de dosimetria de extremidades: validacion e incertidumbre del metodo

    Energy Technology Data Exchange (ETDEWEB)

    Romero Gutierrez, A. M.; Rodriguez Jimenez, R.; Lopez Moyano, J. L.

    2013-07-01

    The authors' goal is to spread the practical experience gained during the accreditation process paying special attention to the process of method validation and estimation uncertainty of the dosimetry system. (Author)

  16. Establishment of a dosimetry method for the exposure evaluation to the ultraviolet radiation

    International Nuclear Information System (INIS)

    Gronchi, Claudia Carla

    2009-01-01

    A dosimetric method for the exposure evaluation to ultraviolet radiation was established with Al 2 O 3 :C InLight detectors and an OSL microStar reader and software, of Landauer, associated to the techniques of Optically Stimulated Luminescence (OSL) and Photo transferred Optically Stimulated Luminescence (PTOSL). The main phases of this work were: characterization of the Al 2 O 3 :C InLight detectors, without pre-conditioning, exposed to ultraviolet radiation (RUV) of solar and artificial sources, using the OSL technique; characterization of the Al 2 O 3 :C InLight detectors, pre-conditioned, exposed to RUV solar and artificial sources, using the PTOSL technique; practical applications of the Al 2 O 3 :C InLight detectors to the solar and artificial RUV, originating from TIG (Tungsten Inert Gas) and electric welding. The Al 2 O 3 :C InLight detectors presented satisfactory OSL and PTOSL responses in relation to the parameters: wavelength, UV illumination time, irradiance, radiance exposure and angular dependence to the RUV. Those detectors presented maximum OSL and PTOSL stimulation for the wavelength of 330 nm, showing that they are may be useful for UVA radiation detection and dosimetry. (author)

  17. Development of irradiation rig in HTTR and dosimetry method. I-I type irradiation equipment

    Energy Technology Data Exchange (ETDEWEB)

    Shibata, Taiju; Kikuchi, Takayuki [Japan Atomic Energy Research Inst., Oarai, Ibaraki (Japan). Oarai Research Establishment; Miyamoto, Satoshi; Ogura, Kazutomo [Japan Atomic Power Co., Tokyo (Japan)

    2002-12-01

    The High Temperature Engineering Test Reactor (HTTR) is a graphite-moderated, helium gas-cooled test reactor with a maximum power of 30 MW. The HTTR aims not only to establish and upgrade the technological basis for the HTGRs but also to perform the innovative basic research on high temperature engineering with high temperature irradiation fields. It is planned that the HTTR is used to perform various engineering tests such as the safety demonstration test, high temperature test operation and irradiation test with large irradiation fields at high temperatures. This paper describes the design of the I-I type irradiation equipment developed as the first irradiation rig for the HTTR and does the planned dosimetry method at the first irradiation test. It was developed to perform in-pile creep test on a stainless steel with large standard size specimens in the HTTR. It can give great loads on the specimens stably and can control the irradiation temperature precisely. The in-core creep properties on the specimens are measured by newly developed differential transformers and the irradiation condition in the core is monitored by thermocouples and self-powered neutron detectors (SPNDs), continuously. The irradiated neutron fluence is assessed by neutron fluence monitors of small metallic wires after the irradiation. The obtained data at the first irradiation test can strongly be contributed to upgrade the technological basis for the HTGRs, since it is the first direct measurement of the in-core irradiation environments of the HTTR. (author)

  18. Creation of voxel-based models for paediatric dosimetry from automatic segmentation methods

    International Nuclear Information System (INIS)

    Acosta, O.; Li, R.; Ourselin, S.; Caon, M.

    2006-01-01

    Full text: The first computational models representing human anatomy were mathematical phantoms, but still far from accurate representations of human body. These models have been used with radiation transport codes (Monte Carlo) to estimate organ doses from radiological procedures. Although new medical imaging techniques have recently allowed the construction of voxel-based models based on the real anatomy, few children models from individual CT or MRI data have been reported [1,3]. For pediatric dosimetry purposes, a large range of voxel models by ages is required since scaling the anatomy from existing models is not sufficiently accurate. The small number of models available arises from the small number of CT or MRI data sets of children available and the long amount of time required to segment the data sets. The existing models have been constructed by manual segmentation slice by slice and using simple thresholding techniques. In medical image segmentation, considerable difficulties appear when applying classical techniques like thresholding or simple edge detection. Until now, any evidence of more accurate or near-automatic methods used in construction of child voxel models exists. We aim to construct a range of pediatric voxel models, integrating automatic or semi-automatic 3D segmentation techniques. In this paper we present the first stage of this work using pediatric CT data.

  19. Biological in vivo dosimetry with external measurement using a labelled DNA precursor (125iododeoxyuridine)

    International Nuclear Information System (INIS)

    Porschen, W.; Zamboglou, N.; Muehlensiepen, H.; Feinendegen, L.E.

    1976-01-01

    The depression of the incorporation rate of ioddeoxyuridine in the whole body and in the bone marrow is a sensitive indicator for a whole-body-irradiation. It was found that the maximum effect occurs appr. 4 hours after the irradiation. This is why bone marrow cells were labelled with IDU in the test tube 4 hrs. after irradiation. This method showed an extraordinary sensitivity and resulted in reproducible effects occurring already with doses less than 5 rad. All dosemeter methods used until now have a lower sensitivity. (orig.) [de

  20. Enhancing Cytogenetic Biological Dosimetry Capabilities of the Philippines for Nuclear Incident Preparedness.

    Science.gov (United States)

    Asaad, Celia O; Caraos, Gloriamaris L; Robles, Gerardo Jose M; Asa, Anie Day D C; Cobar, Maria Lucia C; Asaad, Al-Ahmadgaid

    2016-01-01

    The utility of a biological dosimeter based on the analysis of dicentrics is invaluable in the event of a radiological emergency wherein the estimated absorbed dose of an exposed individual is crucial in the proper medical management of patients. The technique is also used for routine monitoring of occupationally exposed workers to determine radiation exposure. An in vitro irradiation study of human peripheral blood lymphocytes was conducted to establish a dose-response curve for radiation-induced dicentric aberrations. Blood samples were collected from volunteer donors and together with optically stimulated luminescence (OSL) dosimeters and were irradiated at 0, 0.1, 0.25, 0.5, 0.75, 1, 2, 4, and 6 Gy using a cobalt-60 radiotherapy unit. Blood samples were cultured for 48 h, and the metaphase chromosomes were prepared following the procedure of the International Atomic Energy Agency's Emergency Preparedness and Response - Biodosimetry 2011 manual. At least 100 metaphases were scored for dicentric aberrations at each dose point. The data were analyzed using R language program. The results indicated that the distribution of dicentric cells followed a Poisson distribution and the dose-response curve was established using the estimated model, Y dic = 0.0003 (±0.0003) +0.0336 (±0.0115) × D + 0.0236 (±0.0054) × D 2 . In this study, the reliability of the dose-response curve in estimating the absorbed dose was also validated for 2 and 4 Gy using OSL dosimeters. The data were fitted into the constructed curve. The result of the validation study showed that the obtained estimate for the absorbed exposure doses was close to the true exposure doses.

  1. Shoreline clean-up methods : biological treatments

    Energy Technology Data Exchange (ETDEWEB)

    Massoura, S.T. [Oil Spill Response Limited, Southampton (United Kingdom)

    2009-07-01

    The cleanup of oil spills in shoreline environments is a challenging issue worldwide. Oil spills receive public and media attention, particularly in the event of a coastal impact. It is important to evaluate the efficiency and effectiveness of cleanup methods when defining the level of effort and consequences that are appropriate to remove or treat different types of oil on different shoreline substrates. Of the many studies that have compared different mechanical, chemical and biological treatments for their effectiveness on various types of oil, biological techniques have received the most attention. For that reason, this paper evaluated the effectiveness and effects of shoreline cleanup methods using biological techniques. It summarized data from field experiments and oil spill incidents, including the Exxon Valdez, Sea Empress, Prestige, Grand Eagle, Nakhodka, Guanabara Bay and various Gulf war oil spills. Five major shoreline types were examined, notably rocky intertidal, cobble/pebble/gravel, sand/mud, saltmarsh, and mangrove/sea-grass. The biological techniques that were addressed were nutrient enrichment, hydrocarbon-utilizing bacteria, vegetable oil biosolvents, plants, surf washing, oil-particle interactions and natural attenuation. The study considered the oil type, volume and fate of stranded oil, location of coastal materials, extent of pollution and the impact of biological techniques. The main factors that affect biodegradation of hydrocarbons are the volume, chemical composition and weathering state of the petroleum product as well as the temperature, oxygen availability of nutrients, water salinity, pH level, water content, and microorganisms in the shoreline environment. The interaction of these factors also affect the biodegradation of oil. It was concluded that understanding the fate of stranded oil can help in the development of techniques that improve the weathering and degradation of oil on complex shoreline substrates. 39 refs.

  2. Dosimetry in radiotherapy. V.1

    International Nuclear Information System (INIS)

    1988-01-01

    A series of symposia on dosimetry in medicine and biology have been held by the IAEA in co-operation with WHO. The present symposium was the first one focusing on ''Dosimetry in Radiotherapy''. The papers presented reflected the different steps in the calibration chain such as the calibration standards established by the National Standards Laboratories and the conversion of the reading of calibrated instruments to the desired quantity, i.e. absorbed dose to water at a reference point in the user's beam at the radiotherapy clinic. The programme further examined the procedures necessary for optimization of the treatment of the patient, such as treatment planning methods, dose distribution studies, new techniques of dose measurement, improvements in the physical dose distributions/conformation therapy and special problems involved in total body treatments. Results of quality assurance in radiotherapy were presented from local hospitals as well as from national and international studies. Refs, figs and tabs

  3. Development of the FISH technique for biological dosimetry applications in the Gregorio Maranon General University Hospital

    International Nuclear Information System (INIS)

    Moreno, M.; Jesus Prieto, M.; Olivares, P.; Gomez, M.; Herranz, R.

    1997-01-01

    Since 1989 cytogenetic analysis for dose estimation has been regularly used In the Gregorio Maranon General University Hospital (HGUGM) of Madrid on individuals suspected of having accidentally been exposed to ionizing radiation. The method used is the study of chromosomal aberrations found in lymphocytes of peripheral blood. The technique recommended by the IAEA in 1986 permits to establish a dicentrics/dose ratio through an effective dose calibration curve prepared in-vitro. This methodology of dose estimation presents serious limitations which can partially be eliminated by means of new molecular cytogenetic techniques, such as chromosomal painting through in-situ hybridization with fluorescence (FISH). At HGUGM, research work has been finished for standardization of the above mentioned technique including effective dose calibration curves, the utilization of adequate aberrations and the intercomparision of the results with other centres

  4. Biological dosimetry of absorbed radiation by C-banding of interphase chromosomes in peripheral blood lymphocytes

    International Nuclear Information System (INIS)

    Pantelias, G.E.

    1993-01-01

    In the present report a C-banding procedure, refined to avoid swelling and chromosome distortion of freshly prepared prematurely condensed chromosomes (PCCs) spreads, is used to identify aberrations in non-stimulated human lymphocytes. The method allows immediate banding of the centromeric regions and enables scoring of aberrations within a time interval (3-4h after blood sample withdrawal) that is only a fraction of that normally required when cells stimulated to proliferate are analysed at metaphase. The dose-response for dicentrics and centric rings measured in interphase lymphocytes was found to be similar to that obtained at metaphase. Measurement of dicentrics and centric rings in prematurely condensed chromosomes of human lymphocytes would provide valuable information on radiation dose estimates, especially in cases of extreme urgency. (Author)

  5. Chromosomal analysis and application of biological dosimetry in two cases of apparent over exposure; Analisis cromosomico y aplicacion de la dosimetria biologica en dos casos de aparente sobreexposicion

    Energy Technology Data Exchange (ETDEWEB)

    Guerrero C, C.; Brena V, M. [Departamento de Biologia, ININ A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    2002-07-01

    The gamma radiation calibration curve of {sup 60} Co is used which was generated in the ININ Laboratory of Biology to calculate the exposure dose of two workers whose dosemeters marked values above of the limit allowed. The analysis indicates that in a first case, the aberrations frequency corresponded to the basal value, therefore there is not over exposure. The aberrations frequency of the second case is lightly above to the basal value and therefore the probability favors to what the physical dosimetry indicates. (Author)

  6. EPR dosimetry of teeth in past and future accidents: a prospective look at a retrospective method

    Energy Technology Data Exchange (ETDEWEB)

    Haskell, E.H.; Kenner, G.H.; Hayes, R.B. [Utah Univ., Salt Lake City, UT (United States). Center for Applied Dosimetry; Chumak, V.; Shalom, S. [All-Union Scientific Centre of Radiation Medicine, Kiev (Ukraine)

    1996-01-01

    Electron paramagnetic resonance spectroscopy (EPR) of tooth enamel is a relatively new technique for retrospective dosimetry that in the past two years has seen increasing effort towards its development and evaluation. Efforts have centered on determining the accuracy which may be achieved with current measurement techniques as well as the minimum doses detectable. The study was focused on evaluating some factors which influence the accuracy of EPR dosimetry of enamel. Reported are studies on sample intercomparisions, instrumental considerations, and effects of dental x-rays, environmental sunlight and ultraviolet radiation.

  7. EPR dosimetry of teeth in past and future accidents: a prospective look at a retrospective method

    International Nuclear Information System (INIS)

    Haskell, E.H.; Kenner, G.H.; Hayes, R.B.

    1996-01-01

    Electron paramagnetic resonance spectroscopy (EPR) of tooth enamel is a relatively new technique for retrospective dosimetry that in the past two years has seen increasing effort towards its development and evaluation. Efforts have centered on determining the accuracy which may be achieved with current measurement techniques as well as the minimum doses detectable. The study was focused on evaluating some factors which influence the accuracy of EPR dosimetry of enamel. Reported are studies on sample intercomparisions, instrumental considerations, and effects of dental x-rays, environmental sunlight and ultraviolet radiation

  8. Dosimetry Service

    CERN Multimedia

    2006-01-01

    Cern Staff and Users can now consult their dose records for an individual or an organizational unit with HRT. Please see more information on our web page: http://cern.ch/rp-dosimetry Dosimetry Service is open every morning from 8.30 - 12.00. Closed in the afternoons. We would like to remind you that dosimeters cannot be sent to customers by internal mail. Short-term dosimeters (VCT's) must always be returned to the Service after the use and must not be left on the racks in the experimental areas or in the secretariats. Dosimetry Service Tel. 7 2155 Dosimetry.service@cern.ch http://cern.ch/rp-dosimetry

  9. Quantitative autoradiography of radionuclides in biological tissues by high resolution nuclear analysis: application in radio-toxicology and dosimetry

    International Nuclear Information System (INIS)

    Aubineau Laniece, I.

    1997-01-01

    In the framework of radiation damage on cells in living organisms an auto-radiograph, based on the STIC method, has been developed for the particles detection. This apparatus associates a thin scintillator with a photosensitive detector (CCD). The design and the performance of this well adapted tool for low activity biological samples study, are described. (A.L.B.)

  10. Evaluation of ion chamber dependent correction factors for ionisation chamber dosimetry in proton beams using a Monte Carlo method

    International Nuclear Information System (INIS)

    Palmans, H.; Verhaegen, F.

    1995-01-01

    In the last decade, several clinical proton beam therapy facilities have been developed. To satisfy the demand for uniformity in clinical (routine) proton beam dosimetry two dosimetry protocols (ECHED and AAPM) have been published. Both protocols neglect the influence of ion chamber dependent parameters on dose determination in proton beams because of the scatter properties of these beams, although the problem has not been studied thoroughly yet. A comparison between water calorimetry and ionisation chamber dosimetry showed a discrepancy of 2.6% between the former method and ionometry following the ECHED protocol. Possibly, a small part of this difference can be attributed to chamber dependent correction factors. Indications for this possibility are found in ionometry measurements. To allow the simulation of complex geometries with different media necessary for the study of those corrections, an existing proton Monte Carlo code (PTRAN, Berger) has been modified. The original code, that applies Mollire's multiple scattering theory and Vavilov's energy straggling theory, calculates depth dose profiles, energy distributions and radial distributions for pencil beams in water. Comparisons with measurements and calculations reported in the literature are done to test the program's accuracy. Preliminary results of the influence of chamber design and chamber materials on dose to water determination are presented

  11. Evaluation of ion chamber dependent correction factors for ionisation chamber dosimetry in proton beams using a Monte Carlo method

    Energy Technology Data Exchange (ETDEWEB)

    Palmans, H [Ghent Univ. (Belgium). Dept. of Biomedical Physics; Verhaegen, F

    1995-12-01

    In the last decade, several clinical proton beam therapy facilities have been developed. To satisfy the demand for uniformity in clinical (routine) proton beam dosimetry two dosimetry protocols (ECHED and AAPM) have been published. Both protocols neglect the influence of ion chamber dependent parameters on dose determination in proton beams because of the scatter properties of these beams, although the problem has not been studied thoroughly yet. A comparison between water calorimetry and ionisation chamber dosimetry showed a discrepancy of 2.6% between the former method and ionometry following the ECHED protocol. Possibly, a small part of this difference can be attributed to chamber dependent correction factors. Indications for this possibility are found in ionometry measurements. To allow the simulation of complex geometries with different media necessary for the study of those corrections, an existing proton Monte Carlo code (PTRAN, Berger) has been modified. The original code, that applies Mollire`s multiple scattering theory and Vavilov`s energy straggling theory, calculates depth dose profiles, energy distributions and radial distributions for pencil beams in water. Comparisons with measurements and calculations reported in the literature are done to test the program`s accuracy. Preliminary results of the influence of chamber design and chamber materials on dose to water determination are presented.

  12. 2010 Diffraction Methods in Structural Biology

    Energy Technology Data Exchange (ETDEWEB)

    Dr. Ana Gonzalez

    2011-03-10

    Advances in basic methodologies have played a major role in the dramatic progress in macromolecular crystallography over the past decade, both in terms of overall productivity and in the increasing complexity of the systems being successfully tackled. The 2010 Gordon Research Conference on Diffraction Methods in Structural Biology will, as in the past, focus on the most recent developments in methodology, covering all aspects of the process from crystallization to model building and refinement, complemented by examples of structural highlights and complementary methods. Extensive discussion will be encouraged and it is hoped that all attendees will participate by giving oral or poster presentations, the latter using the excellent poster display area available at Bates College. The relatively small size and informal atmosphere of the meeting provides an excellent opportunity for all participants, especially younger scientists, to meet and exchange ideas with leading methods developers.

  13. Application of the bootstrap method to radiolabeled antibody dosimetry from planar images

    International Nuclear Information System (INIS)

    Papenfuss, T.; Saunder, T.H.; Schleyer, P.J.; O'Keefe, G.J.; Scott, A.M.

    2002-01-01

    Full text: Planar imaging dosimetry of radiolabeled antibody treatment uses the MIRD schema to compute dose to an organ from the calculated activity in that and other organs. The calculated activity in an organ is a function of the average count rates in the organ, a standard and an appropriate background measurement. The geometric mean of conjugate averages, together with an attenuation factor is used to provide an approximate attenuation correction. It is sometimes desirable to know the variance of the activity in an organ in order to apply weighted least squares regression to the data. This is particularly important when incorporating more accurate data from autoradiography of biopsied tissue into the analysis, but is also useful when some data points have low signal. While the geometric mean image can be used to calculate the variance of an organ's count rate. It is difficult to calculate the variance of the activity, since the organ in question, the standard and the background all contribute to it. Bootstrap methods are Monte Carlo techniques that can be used to estimate parameters from data and to determine the accuracy of the estimation. By bootstrapping pixel values in the organ, background and standard ROIs, it is possible to calculate many realisations of the organ activity and calculate its variance. As an example, bootstrapping is applied to the pharmacodynamic analysis of 131 I-huA33 in colon. The data includes planar whole body images, and autoradiographs and planar images of a resected colon. Copyright (2002) The Australian and New Zealand Society of Nuclear Medicine Inc

  14. A review of lyoluminescence dosimetry and a new readout method using liquid scintillation techniques

    International Nuclear Information System (INIS)

    Ziemer, P.L.; Hanig, R.; Fayerman, L.K.

    1978-01-01

    Lyoluminescence dosimetry is useful as a personnel monitor and also as a neutron dosimeter. A review of lyoluminescence is given including readout systems, the machanisms of light emission, radiometric characteristics of lyoluminescence dosimeters, factor affecting response and liquid scintillation lyoluminscence readout

  15. Biological dosimetry in astronauts

    International Nuclear Information System (INIS)

    Durante, M.

    1996-01-01

    Due to the unavoidable presence of ionizing radiation in space, astronauts are classified as radiation workers. I fact, dose rate in space is considerably higher than on earth. Radiation dose absorbed after one day in space is close to the dose received by all natural sources, excluding radon, in one year on earth. Large solar particle events can considerably increase this dose, and could even be life threatening for an inadequately protected crew

  16. Review of retrospective dosimetry techniques for external ionising radiation exposures

    International Nuclear Information System (INIS)

    Ainsbury, E. A.; Bakhanova, E.; Barquinero, J. F.; Brai, M.; Chumak, V.; Correcher, V.; Darroudi, F.; Fattibene, P.; Gruel, G.; Guclu, I.; Horn, S.; Jaworska, A.; Kulka, U.; Lindholm, C.; Lloyd, D.; Longo, A.; Marrale, M.; Monteiro Gil, O.; Oestreicher, U.; Pajic, J.; Rakic, B.; Romm, H.; Trompier, F.; Veronese, I.; Voisin, P.; Vral, A.; Whitehouse, C. A.; Wieser, A.; Woda, C.; Wojcik, A.; Rothkamm, K.

    2011-01-01

    The current focus on networking and mutual assistance in the management of radiation accidents or incidents has demonstrated the importance of a joined-up approach in physical and biological dosimetry. To this end, the European Radiation Dosimetry Working Group 10 on 'Retrospective Dosimetry' has been set up by individuals from a wide range of disciplines across Europe. Here, established and emerging dosimetry methods are reviewed, which can be used immediately and retrospectively following external ionising radiation exposure. Endpoints and assays include dicentrics, translocations, premature chromosome condensation, micronuclei, somatic mutations, gene expression, electron paramagnetic resonance, thermoluminescence, optically stimulated luminescence, neutron activation, haematology, protein biomarkers and analytical dose reconstruction. Individual characteristics of these techniques, their limitations and potential for further development are reviewed, and their usefulness in specific exposure scenarios is discussed. Whilst no single technique fulfils the criteria of an ideal dosemeter, an integrated approach using multiple techniques tailored to the exposure scenario can cover most requirements. (authors)

  17. The status of the seventh report in the series Biological Effects of Ionizing Radiations and a revised dosimetry for the Radiation Effects Research Foundation's A-bomb studies

    International Nuclear Information System (INIS)

    Douple, Evan; Jostes, Rick

    2002-01-01

    Results of a National Academies workshop and feasibility study led US Governmental agencies to request the Board on Radiation Effects Research of the National Research Council to commence a risk assessment study in 1998 as the seventh report in the series Biological Effects of Ionizing Radiations (BEIR VII). Originally targeted for completion in the autumn of 2001, the study Potential Health Effects of Exposure to Low Dose, Low-LET Ionizing Radiation was extended until the autumn of 2003 at the request of the sponsors. Two factors contributing to this decision are discussed: a revised dosimetry to update DS86 for the Radiation Effects Research Foundation's A-bomb-survivor studies and the potential for new information to become available from low-dose studies that are under way. Epidemiological and biological data since BEIR V are being considered by a BEIR VII committee composed of 17 members. The committee's statement of task is reviewed along with the major recommendations of the recent National Research Council report on the status of DS86 - recommendations that are being implemented by US and Japan dosimetry working groups. (author)

  18. Methods and Models of the Hanford Internal Dosimetry Program, PNNL-MA-860

    Energy Technology Data Exchange (ETDEWEB)

    Carbaugh, Eugene H.; Bihl, Donald E.; Maclellan, Jay A.; Antonio, Cheryl L.; Hill, Robin L.

    2009-09-30

    The Hanford Internal Dosimetry Program (HIDP) provides internal dosimetry support services for operations at the Hanford Site. The HIDP is staffed and managed by the Radiation and Health Technology group, within the Pacific Northwest National Laboratory (PNNL). Operations supported by the HIDP include research and development, the decontamination and decommissioning of facilities formerly used to produce and purify plutonium, and waste management activities. Radioelements of particular interest are plutonium, uranium, americium, tritium, and the fission and activation product radionuclides 137Cs, 90Sr, and 60Co. This manual describes the technical basis for the design of the routine bioassay monitoring program and for assessment of internal dose. The purposes of the manual are as follows: • Provide assurance that the HIDP derives from a sound technical base. • Promote the consistency and continuity of routine program activities. • Provide a historical record. • Serve as a technical reference for radiation protection personnel. • Aid in identifying and planning for future needs.

  19. ACTIVE AND PARTICIPATORY METHODS IN BIOLOGY: MODELING

    Directory of Open Access Journals (Sweden)

    Brînduşa-Antonela SBÎRCEA

    2011-01-01

    Full Text Available By using active and participatory methods it is hoped that pupils will not only come to a deeper understanding of the issues involved, but also that their motivation will be heightened. Pupil involvement in their learning is essential. Moreover, by using a variety of teaching techniques, we can help students make sense of the world in different ways, increasing the likelihood that they will develop a conceptual understanding. The teacher must be a good facilitator, monitoring and supporting group dynamics. Modeling is an instructional strategy in which the teacher demonstrates a new concept or approach to learning and pupils learn by observing. In the teaching of biology the didactic materials are fundamental tools in the teaching-learning process. Reading about scientific concepts or having a teacher explain them is not enough. Research has shown that modeling can be used across disciplines and in all grade and ability level classrooms. Using this type of instruction, teachers encourage learning.

  20. Individual neutron dosimetry

    International Nuclear Information System (INIS)

    Mauricio, C.L.P.

    1987-01-01

    The most important concepts and development in individual neutron dosimetry are presented, especially the dosimetric properties of the albedo technique. The main problem in albedo dosimetry is to calibrate the dosemeter in the environs of each neutron source. Some of the most used calibration techniques are discussed. The IRD albedo dosemeter used in the routine neutron individual monitoring is described in detail. Its dosimetric properties and calibration methods are discussed. (Author) [pt

  1. Method and apparatus for producing ultralowmass fissionable deposits for reactor neutron dosimetry by recoil ion-implantation

    International Nuclear Information System (INIS)

    Ruddy, F.H.

    1988-01-01

    A method for producing a fissionable deposit of selectively ultralow mass for neutron dosimetry is described comprising the steps of: (a) spacing in opposing relation a substrate and an alpha-emitting parent source which decays to implant into the substrate of fissionable daughter ejected from the parent source as a result of the decay; and (b) holding the opposing relation for a period of time until the parent source decays to form a corresponding mass of isotopically pure fissionable daughter uniformly on the substrate

  2. Whole body MR-PET: a new internal dosimetry method for radiation transport calculation from biokinetic model data

    International Nuclear Information System (INIS)

    Nunes, Ana; Alves, Francisco; Patrício, Miguel

    2014-01-01

    In order to ensure the safe usage of new radiopharmaceuticals in Positron Emission Tomography (PET), it is necessary to quantify the doses delivered to the organs and tissues within the patients’ bodies. A framework that allows estimating the dose delivered by PET has been established by the MIRD Committee [1, 2] and ICRP []. Although this covers the most important terms and concepts in Internal Radiation Dosimetry (IRD), it does not provide a detailed guide to assist in the development of a full dosimetric study. We discuss the development, implementation, assessment and validation of an accurate method for IRD studies of PET radiotracers.

  3. Investigation of a pulsed current annealing method in reusing MOSFET dosimeters for in vivo IMRT dosimetry.

    Science.gov (United States)

    Luo, Guang-Wen; Qi, Zhen-Yu; Deng, Xiao-Wu; Rosenfeld, Anatoly

    2014-05-01

    To explore the feasibility of pulsed current annealing in reusing metal oxide semiconductor field-effect transistor (MOSFET) dosimeters for in vivo intensity modulated radiation therapy (IMRT) dosimetry. Several MOSFETs were irradiated at d(max) using a 6 MV x-ray beam with 5 V on the gate and annealed with zero bias at room temperature. The percentage recovery of threshold voltage shift during multiple irradiation-annealing cycles was evaluated. Key dosimetry characteristics of the annealed MOSFET such as the dosimeter's sensitivity, reproducibility, dose linearity, and linearity of response within the dynamic range were investigated. The initial results of using the annealed MOSFETs for IMRT dosimetry practice were also presented. More than 95% of threshold voltage shift can be recovered after 24-pulse current continuous annealing in 16 min. The mean sensitivity degradation was found to be 1.28%, ranging from 1.17% to 1.52%, during multiple annealing procedures. Other important characteristics of the annealed MOSFET remained nearly consistent before and after annealing. Our results showed there was no statistically significant difference between the annealed MOSFETs and their control samples in absolute dose measurements for IMRT QA (p = 0.99). The MOSFET measurements agreed with the ion chamber results on an average of 0.16% ± 0.64%. Pulsed current annealing provides a practical option for reusing MOSFETs to extend their operational lifetime. The current annealing circuit can be integrated into the reader, making the annealing procedure fully automatic.

  4. Textbook of dosimetry. 4. ed.

    International Nuclear Information System (INIS)

    Ivanov, V.I.

    1999-01-01

    This textbook of dosimetry is devoted to the students in physics and technical physics of high education institutions, confronted with different application of atomic energy as well as with protection of population and environment against ionizing radiations. Atomic energy is highly beneficial for man but unfortunately incorporates potential dangers which manifest in accidents, the source of which is either insufficient training of the personnel, a criminal negligence or insufficient reliability of the nuclear facilities. The majority of the incident and accident events have had as origin the personnel errors. This was the case with both the 'Three Miles Island' (1979) and Chernobyl (1986) NPP accidents. The dosimetry science acquires a vital significance in accident situations since the data obtained by its procedures are essential in choosing the correct immediate actions, behaviour tactics, orientation of liquidation of accident consequences as well as in ensuring the health of population. An important accent is placed in this manual on clarification of the nature of physical processes taken place in dosimetric detectors, in establishing the relation between radiation field characteristics and the detector response as well as in defining different dosimetric quantities. The terminology and the units of physical quantities is based on the international system of units. The book contains the following 15 chapters: 1. Ionizing radiation field; 2. Radiation doses; 3. Physical bases of gamma radiation dosimetry; 4. Ionization dosimetric detectors; 5. Semiconductor dosimetric detectors; 6. Scintillation detection in the gamma radiation dosimetry; 7. Luminescent methods in dosimetry; 8. The photographic and chemical methods of gamma radiation dosimetry; 9. Neutron dosimetry; 10. Dosimetry of high intensity radiation; 11. Dosimetry of high energy Bremsstrahlung; 12. Measurement of the linear energy transfer; 13. Microdosimetry; 14. Dosimetry of incorporated

  5. Medical reference dosimetry using EPR measurements of alanine: Development of an improved method for clinical dose levels

    International Nuclear Information System (INIS)

    Helt-Hansen, Jakob; Andersen, Claus Erik; Rosendal, Flemming; Kofoed, Inger Matilde

    2009-01-01

    Electron spin resonance (EPR) is used to determine the absorbed dose of alanine dosimeters exposed to clinical photon beams in a solid-water phantom. Alanine is potentially suitable for medical reference dosimetry, because of its near water equivalence over a wide energy spectrum, low signal fading, non-destructive measurement and small dosimeter size. Material and Methods. A Bruker EMX-micro EPR spectrometer with a rectangular cavity and a measurement time of two minutes per dosimeter was used for reading of irradiated alanine dosimeters. Under these conditions a new algorithm based on scaling of known spectra was developed to extract the alanine signal. Results. The dose accuracy, including calibration uncertainty, is less than 2% (k=1) above 4 Gy (n=4). The measurement uncertainty is fairly constant in absolute terms (∼30 mGy) and the relative uncertainty therefore rises for dose measurements below 4 Gy. Typical reproducibility is <1% (k=1) above 10 Gy and <2% between 4 and 10 Gy. Below 4 Gy the uncertainty is higher. A depth dose curve measurement was performed in a solid-water phantom irradiated to a dose of 20 Gy at the maximum dose point (dmax) in 6 and 18 MV photon beams. The typical difference between the dose measured with alanine in solid water and the dose measured with an ion chamber in a water tank was about 1%. A difference of 2% between 6 and 18 MV was found, possibly due to non-water equivalence of the applied phantom. Discussion. Compared to previously published methods the proposed algorithm can be applied without normalisation of phase shifts caused by changes in the g-value of the cavity. The study shows that alanine dosimetry is a suitable candidate for medical reference dosimetry especially for quality control applications

  6. Quantitative imaging for clinical dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Bardies, Manuel [INSERM U601, 9 Quai Moncousu, 44093 Nantes (France)]. E-mail: manu@nantes.inserm.fr; Flux, Glenn [Department of Physics, Royal Marsden NHS Trust, Sutton (United Kingdom); Lassmann, Michael [Department of Nuclear Medicine, Julis-Maximilians University, Wuerzburg (Germany); Monsieurs, Myriam [Department of Health Physics, University of Ghent, 9000 Ghent (Belgium); Savolainen, Sauli [Department of Physical Sciences, University of Helsinki and HUS, Helsinki Medical Imaging Center, Helsinki University Central Hospital (Finland); Strand, Sven-Erik [Medical Radiation Physics, Department of Clinical Sciences Lund, Lund University (Sweden)

    2006-12-20

    Patient-specific dosimetry in nuclear medicine is now a legal requirement in many countries throughout the EU for targeted radionuclide therapy (TRT) applications. In order to achieve that goal, an increased level of accuracy in dosimetry procedures is needed. Current research in nuclear medicine dosimetry should not only aim at developing new methods to assess the delivered radiation absorbed dose at the patient level, but also to ensure that the proposed methods can be put into practice in a sufficient number of institutions. A unified dosimetry methodology is required for making clinical outcome comparisons possible.

  7. In-vivo dosimetry in external radiotherapy with amorphous silicon Portal Imaging Devices: from method to clinical validation

    International Nuclear Information System (INIS)

    Boissard, Philippe

    2012-01-01

    In vivo dose verification is used to prevent major deviations between the prescribed dose and the dose really delivered to the patient. This quality control was, nationally and internationally, widely recommended by scientific organizations. In France, its implementation and its use are now regulated. To do this, small detectors are fixed on the patient skin at the beginning of the treatment. However, the treatment delay is increased and not all treatment techniques could be assessed, such as IMRT plans (Intensity Modulated Radiation Therapy). In this context, Transit dosimetry performed with Electronic Portal Imaging Devices (EPIDs) appears as an interesting alternative for in vivo dose verification. During the treatment session, a transit dose is measured with the EPID, in two dimensions, and the dose in the patient is estimated from back projection of the portal dose. This work presents a quick and simple alternative method for verification of dose delivered to the patient using photon beams. Verifications in cases of complexes patient shapes and Intensity Modulated Radiation Therapy (IMRT) have been improved by using a Clarkson-Cunningham's integration method. 46 phantom test cases were designed to assess the accuracy of the method for 4, 6, 10 and 20 MV photon beams. For some points of interest the dose reconstructed by the method is compared to the dose measured with an ionization chamber. An additional in vivo uncertainty due to day to day deviations is defined and investigated. In the same time, a clinical study was driven during three years. In vivo dosimetry was performed for 494 patients treated for various tumors sites. Most of the patients were treated for a prostate cancer using IMRT. The in vivo dose is here compared to the dose calculated by the Treatment Planning System, TPS. The results of these two ways of validations are within the accepted tolerance of classical in vivo dosimetry. From the phantom study, we have estimated that the standard

  8. Biological dosimetry after criticality accidents. Intercomparison exercise in the Silene Reactor - France; Dosimetria biologica en accidentes de criticidad. Ejercicio de intercomparacion en el Reactor Silene - Francia

    Energy Technology Data Exchange (ETDEWEB)

    Di Giorgio, Marina; Vallerga, Maria B; Taja, Maria R [Autoridad Regulatoria Nuclear, Buenos Aires (Argentina); arn gov ar, E-mail: mdigiorg@cae

    2004-07-01

    The Institute of Radiation Protection and Nuclear Safety Institute (IRSN) organized an international biological dosimetry intercomparison, at the SILENE experimental reactor (Valduc, France), simulating different criticality scenarios: bare source 4 Gy, lead shield source 1 and 2 Gy and gamma pure {sup 60}Co source 2 Gy. Fifteen laboratories were involved in this exercise, including the Argentine Biological Dosimetry Laboratory. The purposes of the intercomparison were: 1) To compare the unstable chromosome aberration (UCA) frequency observed by the different laboratories; and 2) To compare the dose estimation for gamma rays and neutrons. The objects of the present work were: I) To compare the mean frequency of UCA observed by the Argentine laboratory with the mean frequency observed by the participant laboratories as a whole. II) To compare the dose estimates performed by the Argentine lab with those estimated by the other laboratories involved in the second stage of the intercomparison. Overall, the mean frequencies of UCA and the correspondent 95% confidence limits obtained by the Argentine lab were consistent with the results obtained by the laboratories as a whole. For the gamma pure scenario, smaller variations were observed among laboratories in terms of dose (CV=18,2%) than in terms of frequency (CV=30,1%). For the mixed field scenarios, only four laboratories, including the Argentine lab, estimated gamma and neutron components of the total dose and just two (Argentine lab and lab 12) were in agreement with the given physical doses. The 1 Gy experiment presented lesser variations both in terms of frequency and dose than the other two scenarios. For the 4 and 2 Gy experiments, variations in neutron dose were more significant than variations in gamma dose, related to the magnitude of the dose. The results suggest that intercomparison exercises jointly with the accreditation of biological dosimetry by cytogenetic service laboratories, in compliance with ISO

  9. ESR Dosimetry

    International Nuclear Information System (INIS)

    Baffa, Oswaldo; Rossi, Bruno; Graeff, Carlos; Kinoshita, Angela; Chen Abrego, Felipe; Santos, Adevailton Bernardo dos

    2004-01-01

    ESR dosimetry is widely used for several applications such as dose assessment in accidents, medical applications and sterilization of food and other materials. In this work the dosimetric properties of natural and synthetic Hydroxyapatite, Alanine, and 2-Methylalanine are presented. Recent results on the use of a K-Band (24 GHz) ESR spectrometer in dosimetry are also presented

  10. Dosimetry Service

    CERN Multimedia

    2005-01-01

    Please remember to read your dosimeter at least once a month. Regular read-outs are vital to ensure that your personal dose is periodically monitored. Dosimeters should be read even if you have not visited the controlled areas. Dosimetry Service - Tel. 7 2155 http://cern.ch/rp-dosimetry

  11. Dosimetry Service

    CERN Multimedia

    Dosimetry Service

    2005-01-01

    Please remember to read your dosimeter at least once a month. Regular read-outs are vital to ensure that your personal dose is periodically monitored. Dosimeters should be read even if you have not visited the controlled areas. Dosimetry Service Tel. 7 2155 http://cern.ch/rp-dosimetry

  12. Dosimetry Service

    CERN Multimedia

    2005-01-01

    Please remember to read your dosimeter at least once a month. Regular read-outs are vital to ensure that your personal dose is periodically monitored. Dosimeters should be read even if you have not visited the controlled areas. Dosimetry Service - Tel. 72155 http://cern.ch/rp-dosimetry

  13. WE-AB-BRB-02: Methods and Applications of 3D Radiochromic Dosimetry

    International Nuclear Information System (INIS)

    Oldham, M.

    2016-01-01

    Despite widespread IMRT treatments at modern radiation therapy clinics, precise dosimetric commissioning of an IMRT system remains a challenge. In the most recent report from the Radiological Physics Center (RPC), nearly 20% of institutions failed an end-to-end test with an anthropomorphic head and neck phantom, a test that has rather lenient dose difference and distance-to-agreement criteria of 7% and 4 mm. The RPC report provides strong evidence that IMRT implementation is prone to error and that improved quality assurance tools are required. At the heart of radiation therapy dosimetry is the multidimensional dosimeter. However, due to the limited availability of water-equivalent dosimetry materials, research and development in this important field is challenging. In this session, we will review a few dosimeter developments that are either in the laboratory phase or in the pre-commercialization phase. 1) Radiochromic plastic. Novel formulations exhibit light absorbing optical contrast with very little scatter, enabling faster, broad beam optical CT design. 2) Storage phosphor. After irradiation, the dosimetry panels will be read out using a dedicated 2D scanning apparatus in a non-invasive, electro-optic manner and immediately restored for further use. 3) Liquid scintillator. Scintillators convert the energy from x-rays and proton beams into visible light, which can be recorded with a scientific camera (CCD or CMOS) from multiple angles. The 3D shape of the dose distribution can then be reconstructed. 4) Cherenkov emission imaging. Gated intensified imaging allows video-rate passive detection of Cherenkov emission during radiation therapy with the room lights on. Learning Objectives: To understand the physics of a variety of dosimetry techniques based upon optical imaging To investigate the strategies to overcome respective challenges and limitations To explore novel ideas of dosimeter design Supported in part by NIH Grants R01CA148853, R01CA182450, R01CA109558

  14. WE-AB-BRB-02: Methods and Applications of 3D Radiochromic Dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Oldham, M. [Duke University Medical Center (United States)

    2016-06-15

    Despite widespread IMRT treatments at modern radiation therapy clinics, precise dosimetric commissioning of an IMRT system remains a challenge. In the most recent report from the Radiological Physics Center (RPC), nearly 20% of institutions failed an end-to-end test with an anthropomorphic head and neck phantom, a test that has rather lenient dose difference and distance-to-agreement criteria of 7% and 4 mm. The RPC report provides strong evidence that IMRT implementation is prone to error and that improved quality assurance tools are required. At the heart of radiation therapy dosimetry is the multidimensional dosimeter. However, due to the limited availability of water-equivalent dosimetry materials, research and development in this important field is challenging. In this session, we will review a few dosimeter developments that are either in the laboratory phase or in the pre-commercialization phase. 1) Radiochromic plastic. Novel formulations exhibit light absorbing optical contrast with very little scatter, enabling faster, broad beam optical CT design. 2) Storage phosphor. After irradiation, the dosimetry panels will be read out using a dedicated 2D scanning apparatus in a non-invasive, electro-optic manner and immediately restored for further use. 3) Liquid scintillator. Scintillators convert the energy from x-rays and proton beams into visible light, which can be recorded with a scientific camera (CCD or CMOS) from multiple angles. The 3D shape of the dose distribution can then be reconstructed. 4) Cherenkov emission imaging. Gated intensified imaging allows video-rate passive detection of Cherenkov emission during radiation therapy with the room lights on. Learning Objectives: To understand the physics of a variety of dosimetry techniques based upon optical imaging To investigate the strategies to overcome respective challenges and limitations To explore novel ideas of dosimeter design Supported in part by NIH Grants R01CA148853, R01CA182450, R01CA109558

  15. Cytogenetic Dosimetry: Applications in Preparedness for and Response to Radiation Emergencies (Arabic Edition)

    International Nuclear Information System (INIS)

    2014-01-01

    Cytogenetic dosimetry is recognized as a valuable dose assessment method which fills a gap in dosimetric technology, particularly when there are difficulties in interpreting the data, in cases where there is reason to believe that persons not wearing dosimeters have been exposed to radiation, in cases of claims for compensation for radiation injuries that are not supported by unequivocal dosimetric evidence, or in cases of exposure over an individual's working lifetime. The IAEA has maintained a long standing involvement in biological dosimetry commencing in 1978. This association has been through a sequence of coordinated research programmes (CRPs), the running of regional and national training courses, the sponsorship of individual training fellowships, and the provision of equipment to laboratories in Member States, establishing capabilities in biological dosimetry. From this has arisen the provision to Member States of advice regarding the best focus for research and suggestions for the most suitable techniques for future practice in biological dosimetry. One CRP resulted in the publication in 1986 of a manual, entitled Biological Dosimetry: Chromosomal Aberration Analysis for Dose Assessment (Technical Reports Series No. 260). This was superseded in 2001 by a revised second edition, Technical Reports Series No. 405. This present publication constitutes a third edition, with extensive updating to reflect the considerable advances that have been made in cytogenetic biological dosimetry during the past decade

  16. Cytogenetic Dosimetry: Applications in Preparedness for and Response to Radiation Emergencies

    International Nuclear Information System (INIS)

    2011-01-01

    Cytogenetic dosimetry is recognized as a valuable dose assessment method which fills a gap in dosimetric technology, particularly when there are difficulties in interpreting the data, in cases where there is reason to believe that persons not wearing dosimeters have been exposed to radiation, in cases of claims for compensation for radiation injuries that are not supported by unequivocal dosimetric evidence, or in cases of exposure over an individual's working lifetime. The IAEA has maintained a long standing involvement in biological dosimetry commencing in 1978. This association has been through a sequence of coordinated research programmes (CRPs), the running of regional and national training courses, the sponsorship of individual training fellowships, and the provision of equipment to laboratories in Member States, establishing capabilities in biological dosimetry. From this has arisen the provision to Member States of advice regarding the best focus for research and suggestions for the most suitable techniques for future practice in biological dosimetry. One CRP resulted in the publication in 1986 of a manual, entitled Biological Dosimetry: Chromosomal Aberration Analysis for Dose Assessment (Technical Reports Series No. 260). This was superseded in 2001 by a revised second edition, Technical Reports Series No. 405. This present publication constitutes a third edition, with extensive updating to reflect the considerable advances that have been made in cytogenetic biological dosimetry during the past decade.

  17. Cytogenetic Dosimetry: Applications in Preparedness for and Response to Radiation Emergencies (Spanish Edition)

    International Nuclear Information System (INIS)

    2014-01-01

    Cytogenetic dosimetry is recognized as a valuable dose assessment method which fills a gap in dosimetric technology, particularly when there are difficulties in interpreting the data, in cases where there is reason to believe that persons not wearing dosimeters have been exposed to radiation, in cases of claims for compensation for radiation injuries that are not supported by unequivocal dosimetric evidence, or in cases of exposure over an individual’s working lifetime. The IAEA has maintained a long standing involvement in biological dosimetry commencing in 1978. This association has been through a sequence of coordinated research programmes (CRPs), the running of regional and national training courses, the sponsorship of individual training fellowships, and the provision of equipment to laboratories in Member States, establishing capabilities in biological dosimetry. From this has arisen the provision to Member States of advice regarding the best focus for research and suggestions for the most suitable techniques for future practice in biological dosimetry. One CRP resulted in the publication in 1986 of a manual, entitled Biological Dosimetry: Chromosomal Aberration Analysis for Dose Assessment (Technical Reports Series No. 260). This was superseded in 2001 by a revised second edition, Technical Reports Series No. 405. This present publication constitutes a third edition, with extensive updating to reflect the considerable advances that have been made in cytogenetic biological dosimetry during the past decade

  18. Cytogenetic Dosimetry: Applications in Preparedness for and Response to Radiation Emergencies (Russian Edition)

    International Nuclear Information System (INIS)

    2014-01-01

    Cytogenetic dosimetry is recognized as a valuable dose assessment method which fills a gap in dosimetric technology, particularly when there are difficulties in interpreting the data, in cases where there is reason to believe that persons not wearing dosimeters have been exposed to radiation, in cases of claims for compensation for radiation injuries that are not supported by unequivocal dosimetric evidence, or in cases of exposure over an individual's working lifetime. The IAEA has maintained a long standing involvement in biological dosimetry commencing in 1978. This association has been through a sequence of coordinated research programmes (CRPs), the running of regional and national training courses, the sponsorship of individual training fellowships, and the provision of equipment to laboratories in Member States, establishing capabilities in biological dosimetry. From this has arisen the provision to Member States of advice regarding the best focus for research and suggestions for the most suitable techniques for future practice in biological dosimetry. One CRP resulted in the publication in 1986 of a manual, entitled Biological Dosimetry: Chromosomal Aberration Analysis for Dose Assessment (Technical Reports Series No. 260). This was superseded in 2001 by a revised second edition, Technical Reports Series No. 405. This present publication constitutes a third edition, with extensive updating to reflect the considerable advances that have been made in cytogenetic biological dosimetry during the past decade

  19. Cytogenetic Dosimetry: Applications in Preparedness for and Response to Radiation Emergencies (Chinese Edition)

    International Nuclear Information System (INIS)

    2015-01-01

    Cytogenetic dosimetry is recognized as a valuable dose assessment method which fills a gap in dosimetric technology, particularly when there are difficulties in interpreting the data, in cases where there is reason to believe that persons not wearing dosimeters have been exposed to radiation, in cases of claims for compensation for radiation injuries that are not supported by unequivocal dosimetric evidence, or in cases of exposure over an individual's working lifetime. The IAEA has maintained a long standing involvement in biological dosimetry commencing in 1978. This association has been through a sequence of coordinated research programmes (CRPs), the running of regional and national training courses, the sponsorship of individual training fellowships, and the provision of equipment to laboratories in Member States, establishing capabilities in biological dosimetry. From this has arisen the provision to Member States of advice regarding the best focus for research and suggestions for the most suitable techniques for future practice in biological dosimetry. One CRP resulted in the publication in 1986 of a manual, entitled Biological Dosimetry: Chromosomal Aberration Analysis for Dose Assessment (Technical Reports Series No. 260). This was superseded in 2001 by a revised second edition, Technical Reports Series No. 405. This present publication constitutes a third edition, with extensive updating to reflect the considerable advances that have been made in cytogenetic biological dosimetry during the past decade

  20. Cytogenetic Dosimetry: Applications in Preparedness for and Response to Radiation Emergencies (French Edition)

    International Nuclear Information System (INIS)

    2013-01-01

    Cytogenetic dosimetry is recognized as a valuable dose assessment method which fills a gap in dosimetric technology, particularly when there are difficulties in interpreting the data, in cases where there is reason to believe that persons not wearing dosimeters have been exposed to radiation, in cases of claims for compensation for radiation injuries that are not supported by unequivocal dosimetric evidence, or in cases of exposure over an individual's working lifetime. The IAEA has maintained a long standing involvement in biological dosimetry commencing in 1978. This association has been through a sequence of coordinated research programmes (CRPs), the running of regional and national training courses, the sponsorship of individual training fellowships, and the provision of equipment to laboratories in Member States, establishing capabilities in biological dosimetry. From this has arisen the provision to Member States of advice regarding the best focus for research and suggestions for the most suitable techniques for future practice in biological dosimetry. One CRP resulted in the publication in 1986 of a manual, entitled Biological Dosimetry: Chromosomal Aberration Analysis for Dose Assessment (Technical Reports Series No. 260). This was superseded in 2001 by a revised second edition, Technical Reports Series No. 405. This present publication constitutes a third edition, with extensive updating to reflect the considerable advances that have been made in cytogenetic biological dosimetry during the past decade

  1. Method and apparatus for biological sequence comparison

    Science.gov (United States)

    Marr, T.G.; Chang, W.I.

    1997-12-23

    A method and apparatus are disclosed for comparing biological sequences from a known source of sequences, with a subject (query) sequence. The apparatus takes as input a set of target similarity levels (such as evolutionary distances in units of PAM), and finds all fragments of known sequences that are similar to the subject sequence at each target similarity level, and are long enough to be statistically significant. The invention device filters out fragments from the known sequences that are too short, or have a lower average similarity to the subject sequence than is required by each target similarity level. The subject sequence is then compared only to the remaining known sequences to find the best matches. The filtering member divides the subject sequence into overlapping blocks, each block being sufficiently large to contain a minimum-length alignment from a known sequence. For each block, the filter member compares the block with every possible short fragment in the known sequences and determines a best match for each comparison. The determined set of short fragment best matches for the block provide an upper threshold on alignment values. Regions of a certain length from the known sequences that have a mean alignment value upper threshold greater than a target unit score are concatenated to form a union. The current block is compared to the union and provides an indication of best local alignment with the subject sequence. 5 figs.

  2. Computational structural biology: methods and applications

    National Research Council Canada - National Science Library

    Schwede, Torsten; Peitsch, Manuel Claude

    2008-01-01

    ... sequencing reinforced the observation that structural information is needed to understand the detailed function and mechanism of biological molecules such as enzyme reactions and molecular recognition events. Furthermore, structures are obviously key to the design of molecules with new or improved functions. In this context, computational structural biology...

  3. Radiation dosimetry in radiotherapy with internal emitters

    International Nuclear Information System (INIS)

    Stabin, Michael G.

    1997-01-01

    Full text. Radiation dosimetry radionuclides are currently being labeled to various biological agents used in internal emitter radiotherapy. This talk will review the various technologies and types of radiolabel in current use, with focus on the characterization of the radiation dose to the various important tissues of the body. Methods for obtaining data, developing kinetic models, and calculating radiation doses will be reviewed. Monoclonal antibodies are currently being labeled with both alpha and beta emitting radionuclides in attempts to find effective agents against cancer. Several radionuclides are also being used as bone pain palliation agents. These agents must be studied in clinical trials to determine the biokinetics and radiation dosimetry prior to approval for general use. In such studies, it is important to ensure the collection of the appropriate kinds of data and to collect the data at appropriate time intervals. The uptake and retention of activity in all significant source organs and in excreta be measured periodically (with at least 2 data points phase of uptake or clearance). Then, correct dosimetry methods must be applied - the best available methods for characterizing the radionuclide kinetic and for estimating the dosimetry in the various organs of the body especially the marrow, should be used. Attempts are also under way to develop methods for estimating true patient-specific dosimetry. Cellular and animal studies are also. Valuable in evaluating the efficacy of the agents in shrinking or eliminating tumors; some results from such studies will also be discussed. The estimation of radiation doses to patients in therapy with internal emitters involves several complex phases of analysis. Careful attention to detail and the use of the best available methods are essential to the protection of the patient and a successful outcome

  4. A novel method for alpha dosimetry using peeled-off Gafchromic EBT3 films

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kwang-Ho; Kim, Eun-Hee [Seoul National University, Seoul (Korea, Republic of)

    2016-10-15

    One can estimate dose imposed to film by measuring the optical density of film. EBT3 film has been used in dose measurement for photon, proton, and electron beams but not for alpha particles. Both sides of diacetylene monomer layer are covered with 100 μm-thick polyester coating layers, through which alpha particles even at several MeV cannot penetrate. A recent study demonstrated the use of EBT3 film in alpha dosimetry by peeling off one side of polyester coating layer. Their study did not inform the reliability of measurement using the peeled-off films. In this study, we evaluated the feasibility of EBT3 film as a substitute for conventional alpha dosimeters and checked the uncertainty of dose measurements obtained with peeled-off EBT3 films. We also applied this film dosimeter to measuring of the fluence distribution at cell targets in a culture dish set in the alpha irradiation chamber of the Radiation Bioengineering Laboratory (RadBio Lab) at Seoul National University (SNU). In this work, we confirmed the feasibility of using Gafchromic EBT3 films for alpha dosimetry. The peeled-off EBT3 films can make a convenient alpha dosimeter by carrying an uncertainty less than 9 %.

  5. Use of spectrophotometric readout method for free radical dosimetry in radiation processing including low energy electrons and bremsstrahlung

    International Nuclear Information System (INIS)

    Gupta, B.L.

    2000-01-01

    Our laboratory maintains standards for high doses in India. The glutamine powder dosimeter (spectrophotometric readout) is used for this purpose. Present studies show that 20 mg of unirradiated/irradiated glutamine dissolved in freshly prepared 10 ml of aerated aqueous acidic FX solution containing 2 x 10 -3 mol dm -3 ferrous ammonium sulphate and 10 -4 mol dm -3 xylenol orange in 0.033 mol dm -3 sulphuric acid is suitable for the dosimetry in the dose range of 0.1-100 kGy. Normally no corrections are required for the post-irradiation fading of the irradiated glutamine. The response of glutamine dosimeter is independent of irradiation temperature in the range of about 23-30 deg. C and at other temperatures, a correction is necessary. The dose intercomparison results for photon, electron and bremsstrahlung radiations show that glutamine can be used as a reference standard dosimeter. The use of flat polyethylene bags containing glutamine powder has proved very successful for electron dosimetry of wide energies. Several other amino acids like alanine, valine and threonine can also be used to cover wide range of doses using spectrophotometric readout method. (author)

  6. The sensitivity analysis of tooth enamel to the absorbed dose for the application to EPR dosimetry

    International Nuclear Information System (INIS)

    Hong, Dae Seok; Lee, Kun Jai; Cho, Young Hwan

    2002-01-01

    Electron Paramagnetic Resonance (EPR) spectroscopy is one of the methods applicable to retrospective dosimetry. The retrospective dosimetry is a process that is a part of dose reconstruction for estimation of exposed dose occurred years before the estimation. Many techniques can be used to the retrospective dosimetry. As a physical method, EPR analysis of biological material measures the quantity of free radicals generated in the material from the interaction of radiation and material. Since the later 80s, in many countries, EPR dosimetry with tooth enamel has been studied and applied for the retrospective dosimetry. In the consideration of the biological materials for EPR dosimetry, human fingernail, hair, bone and tooth are generally considered. The tooth can be separated as enamel, dentine and cementum. Among the three parts, enamel shows the best sensitivity to the absorbed dose and is most widely used. In this study, the characteristics of tooth enamel for EPR dosimetry is examined and experimented. At the experiment, for easy separation, tooth was cut into 4 parts and then each part is treated by ultrasonic vibration in NaOH liquid to reduce mechanically induced noise in the corresponding signal. After the separation of the enamel from dentine, background EPR signal is measured and then radiation-induced EPR spectrum is estimated

  7. GafChromic EBT film dosimetry with flatbed CCD scanner: a novel background correction method and full dose uncertainty analysis.

    Science.gov (United States)

    Saur, Sigrun; Frengen, Jomar

    2008-07-01

    Film dosimetry using radiochromic EBT film in combination with a flatbed charge coupled device scanner is a useful method both for two-dimensional verification of intensity-modulated radiation treatment plans and for general quality assurance of treatment planning systems and linear accelerators. Unfortunately, the response over the scanner area is nonuniform, and when not corrected for, this results in a systematic error in the measured dose which is both dose and position dependent. In this study a novel method for background correction is presented. The method is based on the subtraction of a correction matrix, a matrix that is based on scans of films that are irradiated to nine dose levels in the range 0.08-2.93 Gy. Because the response of the film is dependent on the film's orientation with respect to the scanner, correction matrices for both landscape oriented and portrait oriented scans were made. In addition to the background correction method, a full dose uncertainty analysis of the film dosimetry procedure was performed. This analysis takes into account the fit uncertainty of the calibration curve, the variation in response for different film sheets, the nonuniformity after background correction, and the noise in the scanned films. The film analysis was performed for film pieces of size 16 x 16 cm, all with the same lot number, and all irradiations were done perpendicular onto the films. The results show that the 2-sigma dose uncertainty at 2 Gy is about 5% and 3.5% for landscape and portrait scans, respectively. The uncertainty gradually increases as the dose decreases, but at 1 Gy the 2-sigma dose uncertainty is still as good as 6% and 4% for landscape and portrait scans, respectively. The study shows that film dosimetry using GafChromic EBT film, an Epson Expression 1680 Professional scanner and a dedicated background correction technique gives precise and accurate results. For the purpose of dosimetric verification, the calculated dose distribution

  8. GafChromic EBT film dosimetry with flatbed CCD scanner: A novel background correction method and full dose uncertainty analysis

    International Nuclear Information System (INIS)

    Saur, Sigrun; Frengen, Jomar

    2008-01-01

    Film dosimetry using radiochromic EBT film in combination with a flatbed charge coupled device scanner is a useful method both for two-dimensional verification of intensity-modulated radiation treatment plans and for general quality assurance of treatment planning systems and linear accelerators. Unfortunately, the response over the scanner area is nonuniform, and when not corrected for, this results in a systematic error in the measured dose which is both dose and position dependent. In this study a novel method for background correction is presented. The method is based on the subtraction of a correction matrix, a matrix that is based on scans of films that are irradiated to nine dose levels in the range 0.08-2.93 Gy. Because the response of the film is dependent on the film's orientation with respect to the scanner, correction matrices for both landscape oriented and portrait oriented scans were made. In addition to the background correction method, a full dose uncertainty analysis of the film dosimetry procedure was performed. This analysis takes into account the fit uncertainty of the calibration curve, the variation in response for different film sheets, the nonuniformity after background correction, and the noise in the scanned films. The film analysis was performed for film pieces of size 16x16 cm, all with the same lot number, and all irradiations were done perpendicular onto the films. The results show that the 2-sigma dose uncertainty at 2 Gy is about 5% and 3.5% for landscape and portrait scans, respectively. The uncertainty gradually increases as the dose decreases, but at 1 Gy the 2-sigma dose uncertainty is still as good as 6% and 4% for landscape and portrait scans, respectively. The study shows that film dosimetry using GafChromic EBT film, an Epson Expression 1680 Professional scanner and a dedicated background correction technique gives precise and accurate results. For the purpose of dosimetric verification, the calculated dose distribution can

  9. A method for evaluating treatment quality using in vivo EPID dosimetry and statistical process control in radiation therapy.

    Science.gov (United States)

    Fuangrod, Todsaporn; Greer, Peter B; Simpson, John; Zwan, Benjamin J; Middleton, Richard H

    2017-03-13

    Purpose Due to increasing complexity, modern radiotherapy techniques require comprehensive quality assurance (QA) programmes, that to date generally focus on the pre-treatment stage. The purpose of this paper is to provide a method for an individual patient treatment QA evaluation and identification of a "quality gap" for continuous quality improvement. Design/methodology/approach A statistical process control (SPC) was applied to evaluate treatment delivery using in vivo electronic portal imaging device (EPID) dosimetry. A moving range control chart was constructed to monitor the individual patient treatment performance based on a control limit generated from initial data of 90 intensity-modulated radiotherapy (IMRT) and ten volumetric-modulated arc therapy (VMAT) patient deliveries. A process capability index was used to evaluate the continuing treatment quality based on three quality classes: treatment type-specific, treatment linac-specific, and body site-specific. Findings The determined control limits were 62.5 and 70.0 per cent of the χ pass-rate for IMRT and VMAT deliveries, respectively. In total, 14 patients were selected for a pilot study the results of which showed that about 1 per cent of all treatments contained errors relating to unexpected anatomical changes between treatment fractions. Both rectum and pelvis cancer treatments demonstrated process capability indices were less than 1, indicating the potential for quality improvement and hence may benefit from further assessment. Research limitations/implications The study relied on the application of in vivo EPID dosimetry for patients treated at the specific centre. Sampling patients for generating the control limits were limited to 100 patients. Whilst the quantitative results are specific to the clinical techniques and equipment used, the described method is generally applicable to IMRT and VMAT treatment QA. Whilst more work is required to determine the level of clinical significance, the

  10. Dosimetry in radionuclide therapy

    International Nuclear Information System (INIS)

    Riccabona, G.

    2001-01-01

    While it is known that therapeutic effects of radionuclides are due to absorbed radiation dose and to radiosensitivity, individual dosimetry in 'Gy' is practiced rarely in clinical Nuclear Medicine but 'doses' are described in 'mCi' or 'MBq', which is only indirectly related to 'Gy' in the target. To estimate 'Gy', the volume of the target, maximum concentration of the radiopharmaceutical in it and residence time should be assessed individually. These parameters can be obtained usually only with difficulty, involving possibly also quantitative SPET or PET, modern imaging techniques (sonography, CT, MRT), substitution of y- or positron emitting radiotracers for β - emitting radiopharmaceuticals as well as whole-body distribution studies. Residence time can be estimated by obtaining data on biological half-life of a comparable tracer and transfer of these data in the physical characteristics of the therapeutic agent. With all these possibilities for gross dosimetry the establishment of a dose-response-relation should be possible. As distribution of the radiopharmaceutical in lesions is frequently inhomogenous and microdosimetric conditions are difficult to assess in vivo as yet, it could be observed since decades that empirically set, sometimes 'fixed' doses (mCi or MBq) can also be successful in many diseases. Detailed dosimetric studies, however, are work- and cost-intensive. Nevertheless, one should be aware at a time when more sophisticated therapeutic possibilities in Nuclear Medicine arise, that we should try to estimate radiation dose (Gy) in our new methods even as differences in individual radiosensitivity cannot be assessed yet and studies to define individual radiosensitivity in lesions should be encouraged. (author)

  11. Establishment of a new calibration method of pencil ionization chamber for dosimetry in computed tomography

    International Nuclear Information System (INIS)

    Dias, Daniel Menezes

    2010-01-01

    Pencil ionization chambers are used for beam dosimetry in computed tomography equipment (CT). In this study, a new calibration methodology was established, in order to make the Calibration Laboratory of Instituto de Pesquisas Energeticas e Nucleares (LCI) suitable to international metrological standards, dealing with specific procedures for calibration of these chambers used in CT. Firstly, the setup for the new RQT radiation qualities was mounted, in agreement with IEC61267 from the International Electrotechnical Commission (IEC). After the establishment of these radiation qualities, a specific calibration methodology for pencil ionization chambers was set, according to Technical Report Series No. 457, from the International Atomic Energy Agency (IAEA), which describes particularities of the procedure to be followed by the Secondary Standard Dosimetry Laboratories (SSDL's), concerning to collimation and positioning related to the radiation beam. Initially, PPV (kV) measurements and the determination of copper additional filtrations were carried out, measuring the half value layers (HVL) recommended by the IEC 61267 standard, after that the RQT 8, RQT 9 and RQT 10 radiation quality references were established. For additional filters, aluminum and copper of high purity (around 99.9%) were used. RQT's in thickness of copper filters equivalent to the set 'RQR (Al) + Additional Filtration (Cu)' was directly found by an alternative methodology used to determine additional filtrations, which is a good option when RQR's have not the possibility of be setting up. With the establishment of this new methodology for the ionization pencil chambers calibration, the LCI is ready to calibrate these instruments according to the most recent international standards. Therefore, an improvement in calibration traceability, as well as in metrological services offered by IPEN to all Brazil is achieved. (author)

  12. A mathematical approach to optimal selection of dose values in the additive dose method of ERP dosimetry

    International Nuclear Information System (INIS)

    Hayes, R.B.; Haskell, E.H.; Kenner, G.H.

    1996-01-01

    Additive dose methods commonly used in electron paramagnetic resonance (EPR) dosimetry are time consuming and labor intensive. We have developed a mathematical approach for determining optimal spacing of applied doses and the number of spectra which should be taken at each dose level. Expected uncertainitites in the data points are assumed to be normally distributed with a fixed standard deviation and linearity of dose response is also assumed. The optimum spacing and number of points necessary for the minimal error can be estimated, as can the likely error in the resulting estimate. When low doses are being estimated for tooth enamel samples the optimal spacing is shown to be a concentration of points near the zero dose value with fewer spectra taken at a single high dose value within the range of known linearity. Optimization of the analytical process results in increased accuracy and sample throughput

  13. Creative design inspired by biological knowledge: Technologies and methods

    Science.gov (United States)

    Tan, Runhua; Liu, Wei; Cao, Guozhong; Shi, Yuan

    2018-05-01

    Biological knowledge is becoming an important source of inspiration for developing creative solutions to engineering design problems and even has a huge potential in formulating ideas that can help firms compete successfully in a dynamic market. To identify the technologies and methods that can facilitate the development of biologically inspired creative designs, this research briefly reviews the existing biological-knowledge-based theories and methods and examines the application of biological-knowledge-inspired designs in various fields. Afterward, this research thoroughly examines the four dimensions of key technologies that underlie the biologically inspired design (BID) process. This research then discusses the future development trends of the BID process before presenting the conclusions.

  14. Radiation dosimetry and radiation biophysics

    International Nuclear Information System (INIS)

    Anon.

    1981-01-01

    Radiation dosimetry and radiation biophysics are two closely integrated programs whose joint purpose is to explore the connections between the primary physical events produced by radiation and their biological consequences in cellular systems. The radiation dosimetry program includes the theoretical description of primary events and their connection with the observable biological effects. This program also is concerned with the design and measurement of physical parameters used in theory or to support biological experiments. The radiation biophysics program tests and uses the theoretical developments for experimental design, and provides information for further theoretical development through experiments on cellular systems

  15. Radiation dosimetry and radiation biophysics

    International Nuclear Information System (INIS)

    Anon.

    1979-01-01

    Radiation dosimetry and radiation biophysics are two closely integrated programs whose joint purpose is to explore the connections between the primary physical events produced by radiation and their biological consequences in cellular systems. The radiation dosimetry program includes the theoretical description of primary events and their connection with the observable biological effects. This program also is concerned with design and measurement of those physical parameters used in the theory or to support biological experiments. The radiation biophysics program tests and makes use of the theoretical developments for experimental design. Also, this program provides information for further theoretical development through experiments on cellular systems

  16. Solid state radiation dosimetry

    International Nuclear Information System (INIS)

    Moran, P.R.

    1976-01-01

    Important recent developments provide accurate, sensitive, and reliable radiation measurements by using solid state radiation dosimetry methods. A review of the basic phenomena, devices, practical limitations, and categories of solid state methods is presented. The primary focus is upon the general physics underlying radiation measurements with solid state devices

  17. Investigation and quality assurance of numerical methods in radiation protection and dosimetry

    International Nuclear Information System (INIS)

    Chartier, J.L.

    2000-01-01

    This report is primarily intended as a non-exhaustive overview of and a pointer to some of the major Monte Carlo and deterministic codes used in radiation transport in general and radiation protection and dosimetry in particular, with an extended bibliography for those codes. These will include MCNP, EGS, LAHET, FLUKA, MARS, MCBEND, TRIPOLI, SCALES and others. Some deterministic codes such as ANISM, TORT, EVENT, ect. will also be described in some detail, as will be although briefly, BEAM, PEREGRINE and rtt M C which are used in medical physics applications. The codes' order of description and the amount space dedicated to each of them has been randomly dedicated by the time when the sections were written and by their authorship. In this challenging and ambitious exercise, wherever possible (and it has not been easy), the involvement and help of the authors or main developers and users of the codes were sought, at least through their regularly updated web sites. This work, however, stopped short of being either a strong inter-comparison or a benchmarking exercise

  18. The calibration method for personal dosimetry system in photon and neutron radiation fields

    Energy Technology Data Exchange (ETDEWEB)

    Trousil, J; Plichta, J [CSOD, Prague (Czech Republic); Nikodemova, D [SOD, Bratislava (Slovakia)

    1996-12-31

    The type testing of dosimetry system was performed with standard photon radiation fields within the energy range 15 keV to 1.25 MeV and electron radiation fields within the range 0.2 MeV to 3 MeV. For type testing of neutron dosimeters {sup 252}Cf and {sup 241}Am-Be radionuclide neutron sources was used, as well as a 14 MeV neutron generator. The neutron sources moderated by various moderating and absorbing materials was also used. The routine calibration of individual photon dosemeters was carried out using a {sup 137}Cs calibration source in the air kerma quality in the dose range 0.2 mGy to 6 Gy. The type testing of neutron dosemeters was performed in collaboration with Nueherberg laboratory on neutron generator with neutron energies -.57; 1.0;; 5.3 and 15.1 MeV. The fading and angular dependence testing was also included in the tests of both dosemeter systems. (J.K.).

  19. Dosimetry in life sciences

    International Nuclear Information System (INIS)

    1975-01-01

    The uses of radiation in medicine and biology have grown in scope and diversity to make the Radiological Sciences a significant factor in both research and medical practice. Of critical importance in the applications and development of biomedical and radiological techniques is the precision with which the dose may be determined at all points of interest in the absorbing medium. This has developed as a result of efficacy of investigations in clinical radiation therapy, concern for patient safety and diagnostic accuracy in diagnostic radiology and the advent of clinical trials and research into the use of heavily ionizing radiations in biology and medicine. Since the last IAEA Symposium on Dosimetry Techniques applied to Agriculture, Industry, Biology and Medicine, held in Vienna in 1972, it has become increasingly clear that advances in the techniques and hardware of biomedical dosimetry have been rapid. It is for these reasons that this symposium was organized in a concerted effort to focus on the problems, developments and areas of further research in dosimetry in the Life Sciences. (author)

  20. Dosimetry in life sciences

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1975-06-15

    The uses of radiation in medicine and biology have grown in scope and diversity to make the Radiological Sciences a significant factor in both research and medical practice. Of critical importance in the applications and development of biomedical and radiological techniques is the precision with which the dose may be determined at all points of interest in the absorbing medium. This has developed as a result of efficacy of investigations in clinical radiation therapy, concern for patient safety and diagnostic accuracy in diagnostic radiology and the advent of clinical trials and research into the use of heavily ionizing radiations in biology and medicine. Since the last IAEA Symposium on Dosimetry Techniques applied to Agriculture, Industry, Biology and Medicine, held in Vienna in 1972, it has become increasingly clear that advances in the techniques and hardware of biomedical dosimetry have been rapid. It is for these reasons that this symposium was organized in a concerted effort to focus on the problems, developments and areas of further research in dosimetry in the Life Sciences. (author)

  1. External dosimetry - Applications to radiation protection

    International Nuclear Information System (INIS)

    Faussot, Alain

    2011-01-01

    Dosimetry is the essential component of radiation protection. It allows to determine by calculation and measurement the absorbed dose value, i.e. the energy amounts deposited in matter by ionizing radiations. It deals also with the irradiation effects on living organisms and with their biological consequences. This reference book gathers all the necessary information to understand and master the external dosimetry and the metrology of ionizing radiations, from the effects of radiations to the calibration of radiation protection devices. The first part is devoted to physical dosimetry and allows to obtain in a rigorous manner the mathematical formalisms leading to the absorbed dose for different ionizing radiation fields. The second part presents the biological effects of ionizing radiations on living matter and the determination of a set of specific radiation protection concepts and data to express the 'risk' to develop a radio-induced cancer. The third part deals with the metrology of ionizing radiations through the standardized study of the methods used for the calibration of radiation protection equipments. Some practical exercises with their corrections are proposed at the end of each chapter

  2. Glucinium dosimetry in beryl

    International Nuclear Information System (INIS)

    Kremer, M.

    1949-05-01

    The application of the method developed by Kolthoff and Sandell (1928) for the dosimetry of glucinium (beryllium) in beryl gives non-reproducible results with up to 20% discrepancies. This method recommends to separate beryllium and aluminium using 8 hydroxyquinoline and then to directly precipitate glucinium in the filtrate using ammonia. One possible reason of the problems generated by this method should be the formation of a volatile complex between beryllium and the oxine. This work shows that when the oxine is eliminated before the precipitation with ammonia the dosimetry of beryllium becomes accurate. The destruction of the oxine requires the dry evaporation of the filtrate, which is a long process. Thus the search for a reagent allowing the quantitative precipitation of beryllium in its solutions and in presence of oxine has been made. It has been verified also that the quantitative precipitation of the double beryllium and ammonium phosphate is not disturbed by the oxine in acetic buffer. This method, which gives good results, has also the advantage to separate beryllium from the alkaline-earth compounds still present in the filtrate. The report details the operation mode of the method: beryllium dosimetry using ammonium phosphate, aluminium-beryllium separation, application to beryl dosimetry (ore processing, insolubilization of silica, precipitation with ammonia, precipitation with oxine, precipitation of PO 4 NH 4 Gl, preciseness). (J.S.)

  3. Calibration of SSTR neutron dosimetry for TMI-2 applications

    International Nuclear Information System (INIS)

    Gold, R.; Ruddy, F.H.; Roberts, J.H.; Preston, C.C.; Ulseth, J.A.; McElroy, W.N.; Leitz, F.J.; Hayward, B.R.; Schmittroth, F.A.

    1982-01-01

    Application of neutron dosimetry for assessment of fuel distribution throughout the Three Mile Island-2 (TMI-2) reactor-core region and the primary-coolant system is advanced. Neutron dosimetry in the reactor cavity, i.e. the cavity between the pressure vessel and the biological shield, could provide data for the assessment of the core fuel distribution. A more immediate task entails locating and quantifying the amount of fuel debris in the ex-core primary coolant system; in the range of 1 to 1000 kg. Solid-state track-recorder (SSTR) neutron dosimetry is considered for such exploratory scoping experiments at TMI-2. The sensitivity of mica- 235 U (asymptotically thick) SSTR has been ascertained for such environments. It has been demonstrated that the SSTR method has adequate sensitivity to properly respond and detect fuel quantities of the order of 1 kg in the ex-core primary coolant system. 21 figures

  4. Alanine EPR dosimetry of therapeutic irradiators

    International Nuclear Information System (INIS)

    Bugay, O.; Bartchuk, V.; Kolesnik, S.; Mazin, M.; Gaponenko, H.

    1999-01-01

    The high-dose alanine EPR dosimetry is a very precise method in the dose range 1-100 kGy. The system is used generally as the standard high-dose transfer dosimetry in many laboratories. This is comparatively expensive technique so it is important to use it as a more universal dosimetry system also in the middle and low dose ranges. The problems of the middle-dose alanine dosimetry are discussed and the solution of several problems is proposed. The alanine EPR dosimetry has been applied to the dose measurements of medical irradiators in the Kiev City Oncology Center. (author)

  5. Methods of small parameter in mathematical biology

    CERN Document Server

    Banasiak, Jacek

    2014-01-01

    This monograph presents new tools for modeling multiscale biological processes. Natural processes are usually driven by mechanisms widely differing from each other in the time or space scale at which they operate and thus should be described by appropriate multiscale models. However, looking at all such scales simultaneously is often infeasible, costly, and provides information that is redundant for a particular application. Hence, there has been a growing interest in providing a more focused description of multiscale processes by aggregating variables in a way that is relevant and preserves the salient features of the dynamics. The aim of this book is to present a systematic way of deriving the so-called limit equations for such aggregated variables and ensuring that the coefficients of these equations encapsulate the relevant information from the discarded levels of description. Since any approximation is only valid if an estimate of the incurred error is available, the tools described allow for proving tha...

  6. TU-E-201-01: Methods for Eye Lens Dosimetry and Studies On Lens Opacities with Interventionists

    Energy Technology Data Exchange (ETDEWEB)

    Rehani, M. [Massachusetts General Hospital (United States)

    2015-06-15

    Madan M. Rehani, Massachusetts General Hospital and Harvard Medical School, Boston Methods for Eye Lens Dosimetry and Studies On Lens Opacities with Interventionalists Radiation induced cataract is a major threat among staff working in interventional suites. Nearly 16 million interventional procedures are performed annually in USA. Recent studies by the principal investigator’s group, primarily among interventional cardiologists, on behalf of the International Atomic Energy Agency, show posterior subcapsular (PSC) changes in the eye lens in 38–53% of main operators and 21–45% of support staff. These changes have potential to lead to cataract in future years, as per information from A-Bomb survivors. The International Commission on Radiological Protection has reduced dose limit for staff by a factor of 7.5 (from 150 mSv/y to 20 mSv/y). With increasing emphasis on radiation induced cataracts and reduction in threshold dose for eye lens, there is a need to implement strategies for estimating eye lens dose. Unfortunately eye lens dosimetry is at infancy when it comes to routine application. Various approaches are being tried namely direct measurement using active or passive dosimeters kept close to eyes, retrospective estimations and lastly correlating patient dose in interventional procedures with staff eye dose. The talk will review all approaches available and ongoing active research in this area, as well as data from surveys done in Europe on status of eye dose monitoring in interventional radiology and nuclear medicine. The talk will provide update on how good is Hp(10) against Hp(3), estimations from CTDI values, Monte Carlo based simulations and current status of eye lens dosimetry in USA and Europe. The cataract risk among patients is in CT examinations of the head. Since radiation induced cataract predominantly occurs in posterior sub-capsular (PSC) region and is thus distinguishable from age or drug related cataracts and is also preventable, actions on

  7. TU-E-201-01: Methods for Eye Lens Dosimetry and Studies On Lens Opacities with Interventionists

    International Nuclear Information System (INIS)

    Rehani, M.

    2015-01-01

    Madan M. Rehani, Massachusetts General Hospital and Harvard Medical School, Boston Methods for Eye Lens Dosimetry and Studies On Lens Opacities with Interventionalists Radiation induced cataract is a major threat among staff working in interventional suites. Nearly 16 million interventional procedures are performed annually in USA. Recent studies by the principal investigator’s group, primarily among interventional cardiologists, on behalf of the International Atomic Energy Agency, show posterior subcapsular (PSC) changes in the eye lens in 38–53% of main operators and 21–45% of support staff. These changes have potential to lead to cataract in future years, as per information from A-Bomb survivors. The International Commission on Radiological Protection has reduced dose limit for staff by a factor of 7.5 (from 150 mSv/y to 20 mSv/y). With increasing emphasis on radiation induced cataracts and reduction in threshold dose for eye lens, there is a need to implement strategies for estimating eye lens dose. Unfortunately eye lens dosimetry is at infancy when it comes to routine application. Various approaches are being tried namely direct measurement using active or passive dosimeters kept close to eyes, retrospective estimations and lastly correlating patient dose in interventional procedures with staff eye dose. The talk will review all approaches available and ongoing active research in this area, as well as data from surveys done in Europe on status of eye dose monitoring in interventional radiology and nuclear medicine. The talk will provide update on how good is Hp(10) against Hp(3), estimations from CTDI values, Monte Carlo based simulations and current status of eye lens dosimetry in USA and Europe. The cataract risk among patients is in CT examinations of the head. Since radiation induced cataract predominantly occurs in posterior sub-capsular (PSC) region and is thus distinguishable from age or drug related cataracts and is also preventable, actions on

  8. Image in nuclear dosimetry using thermoluminescent dosimetry

    International Nuclear Information System (INIS)

    Guinsburg, G.; Matsuoka, M.; Watanabe, S.

    1987-01-01

    A low cost methodology to produce images of internal sick organs by radioisotopic intake, is presented. Dosimetries of thermoluminescent material and Teflon (ratio:50%) in bidimensional matrix shape are used with a Pb collimator. This collimator-bidimensional matrix system was tested ''in vivo'' and in thyroid phantoms using 99m Tc. A comparative evaluation between this method and the scintigraphy one is presented. (M.A.C.) [pt

  9. Personnel photographic film dosimetry

    International Nuclear Information System (INIS)

    Keirim-Markus, I.B.

    1981-01-01

    Technology of personnel photographic film dosimetry (PPD) based on the photographic effect of ionizing radiation is described briefly. Kinds of roentgen films used in PPD method are enumerated, compositions of a developer and fixing agents for these films are given [ru

  10. Transmission portal in vivo dosimetry by means of the Monte Carlo method and the mathematical programming language MATLAB

    International Nuclear Information System (INIS)

    BadraouiCuprova, K.

    2014-01-01

    Modern radiotherapy has increased demand for dose delivery verification. In this paper transmission portal dosimetry was considered. Portal detectors are a promising tool for 2D dosimetric verification and they are nowadays one of the most widely investigated topics. In this study an Electronic Portal Imaging Device (EPID) was positioned below the patient and the transmission images were captured during the irradiation. The principle of this verification consists of comparison of the acquired images with images predicted on the basis of the entrance fluence map and the tissue distribution in the patient. Such verification is not performed at any radiotherapy department in the Czech Republic. There is no system available for the prediction of transmission portal images. Even worldwide, there is still a lack of commercially available solutions. The aim of this paper is to present a new method of prediction of transmission portal images by means of the Monte Carlo (MC) method and the mathematical programming language MATLAB. The MC code EGSnrc (Electron Gamma Shower) was used. The validity of the presented method was verified by comparison of the predicted images with the acquired ones. The acquisition of EPID images was performed at the Hospital Na Bulovce. Three different validation tests were performed. In the first case, the EPID was irradiated by regular and irregular fields while there was nothing present in the beam path. In the second case, a water-equivalent phantom was added to the EPID and was irradiated by a number of irregular fields. In the third case, a real patient was present in the beam path and the EPID images were acquired during the patient's treatment. The patient was irradiated by 8 treatment fields and the portal images were acquired during 5 treatment fractions. All of the acquired images were compared with the MC predicted ones by gamma analysis with gamma criteria of 3%, 3 mm. The average gamma values were 0.31-0.4, 0.34-0.4 and 0.35-0.61 in

  11. A method to generate equivalent energy spectra and filtration models based on measurement for multidetector CT Monte Carlo dosimetry simulations

    International Nuclear Information System (INIS)

    Turner, Adam C.; Zhang Di; Kim, Hyun J.; DeMarco, John J.; Cagnon, Chris H.; Angel, Erin; Cody, Dianna D.; Stevens, Donna M.; Primak, Andrew N.; McCollough, Cynthia H.; McNitt-Gray, Michael F.

    2009-01-01

    The purpose of this study was to present a method for generating x-ray source models for performing Monte Carlo (MC) radiation dosimetry simulations of multidetector row CT (MDCT) scanners. These so-called ''equivalent'' source models consist of an energy spectrum and filtration description that are generated based wholly on the measured values and can be used in place of proprietary manufacturer's data for scanner-specific MDCT MC simulations. Required measurements include the half value layers (HVL 1 and HVL 2 ) and the bowtie profile (exposure values across the fan beam) for the MDCT scanner of interest. Using these measured values, a method was described (a) to numerically construct a spectrum with the calculated HVLs approximately equal to those measured (equivalent spectrum) and then (b) to determine a filtration scheme (equivalent filter) that attenuates the equivalent spectrum in a similar fashion as the actual filtration attenuates the actual x-ray beam, as measured by the bowtie profile measurements. Using this method, two types of equivalent source models were generated: One using a spectrum based on both HVL 1 and HVL 2 measurements and its corresponding filtration scheme and the second consisting of a spectrum based only on the measured HVL 1 and its corresponding filtration scheme. Finally, a third type of source model was built based on the spectrum and filtration data provided by the scanner's manufacturer. MC simulations using each of these three source model types were evaluated by comparing the accuracy of multiple CT dose index (CTDI) simulations to measured CTDI values for 64-slice scanners from the four major MDCT manufacturers. Comprehensive evaluations were carried out for each scanner using each kVp and bowtie filter combination available. CTDI experiments were performed for both head (16 cm in diameter) and body (32 cm in diameter) CTDI phantoms using both central and peripheral measurement positions. Both equivalent source model types

  12. Dosimetry in radioisotope placentography

    International Nuclear Information System (INIS)

    Sastry, K.G.K.; Reddy, A.R.; Nagaratnam, A.

    1976-01-01

    Radionuclide investigation of the placenta is being widely used in recent years for the diagnosis and management of vaginal bleeding in the third trimester of pregnancy. One is, therefore, concerned about the radiation exposure to the foetus during such procedures. In the present communication a precise method of estimation of radiation doses is presented. A concept termed 'effective absorbed dose constant' is utilized to enable the absorbed fractions and equilibrium absorbed dose constants to be more easily employed in radiation dose estimations. Tables of the effective absorbed dose constants for radionuclides like 131 I, 123 I, sup(113m)Tc, sup(99m)Tc, 67 Ga, and 51 Cr, are given for different masses and shapes. Masses of different organs of both mother and foetus at different periods of pregnancy and the biological turnover data for different radiopharmaceuticals are reviewed and typical values are presented. Radiation doses to different organs of both mother and foetus at the 30th week of pregnancy are finally estimated for 131 I-HSA, 123 I-SHA, sup(99m)Tc-HSA and sup(113m)In-chloride. The advantage of the effective absorbed dose constants in radiation dosimetry in general is discussed. The relative merits of different radiopharmaceuticals for placental investigations are brought out in comparison with antenatal pelvimetric and abdominal X-ray investigations, from the point of view of radiation doses. (author)

  13. Biologically inspired optimization methods an introduction

    CERN Document Server

    Wahde, M

    2008-01-01

    The advent of rapid, reliable and cheap computing power over the last decades has transformed many, if not most, fields of science and engineering. The multidisciplinary field of optimization is no exception. First of all, with fast computers, researchers and engineers can apply classical optimization methods to problems of larger and larger size. In addition, however, researchers have developed a host of new optimization algorithms that operate in a rather different way than the classical ones, and that allow practitioners to attack optimization problems where the classical methods are either not applicable or simply too costly (in terms of time and other resources) to apply.This book is intended as a course book for introductory courses in stochastic optimization algorithms (in this book, the terms optimization method and optimization algorithm will be used interchangeably), and it has grown from a set of lectures notes used in courses, taught by the author, at the international master programme Complex Ada...

  14. Dosimetry and shielding

    International Nuclear Information System (INIS)

    Farinelli, U.

    1977-01-01

    Today, reactor dosimetry and shielding have wide areas of overlap as concerns both problems and methods. Increased interchange of results and know-how would benefit both. The areas of common interest include calculational methods, sensitivity studies, theoretical and experimental benchmarks, cross sections and other nuclear data, multigroup libraries and procedures for their adjustment, experimental techniques and damage functions. This paper reviews the state-of-the-art and the latest development in each of these areas as far as shielding is concerned, and suggests a number of interactions that could be profitable for reactor dosimetry. Among them, re-evaluation of the potentialities of calculational methods (in view of the recent developments) in predicting radiation environments of interest; the application of sensitivity analysis to dosimetry problems; a common effort in the field of theoretical benchmarks; the use of the shielding one-material propagation experiments as reference spectra for detector cross sections; common standardization of the detector nuclear data used in both fields; the setting up of a common (or compatible) multigroup structure and library applicable to shielding, dosimetry and core physics; the exchange of information and experience in the fields of cross section errors, correlations and adjustment; and the intercomparison of experimental techniques

  15. Accuracy of two simple methods for estimation of thyroidal 131I kinetics for dosimetry-based treatment of Graves' disease

    International Nuclear Information System (INIS)

    Traino, A. C.; Xhafa, B.

    2009-01-01

    One of the major challenges to the more widespread use of individualized, dosimetry-based radioiodine treatment of Graves' disease is the development of a reasonably fast, simple, and cost-effective method to measure thyroidal 131 I kinetics in patients. Even though the fixed activity administration method does not optimize the therapy, giving often too high or too low a dose to the gland, it provides effective treatment for almost 80% of patients without consuming excessive time and resources. In this article two simple methods for the evaluation of the kinetics of 131 I in the thyroid gland are presented and discussed. The first is based on two measurements 4 and 24 h after a diagnostic 131 I administration and the second on one measurement 4 h after such an administration and a linear correlation between this measurement and the maximum uptake in the thyroid. The thyroid absorbed dose calculated by each of the two methods is compared to that calculated by a more complete 131 I kinetics evaluation, based on seven thyroid uptake measurements for 35 patients at various times after the therapy administration. There are differences in the thyroid absorbed doses between those derived by each of the two simpler methods and the ''reference'' value (derived by more complete uptake measurements following the therapeutic 131 I administration), with 20% median and 40% 90-percentile differences for the first method (i.e., based on two thyroid uptake measurements at 4 and 24 h after 131 I administration) and 25% median and 45% 90-percentile differences for the second method (i.e., based on one measurement at 4 h post-administration). Predictably, although relatively fast and convenient, neither of these simpler methods appears to be as accurate as thyroid dose estimates based on more complete kinetic data.

  16. Biological dosimetry - a Bayesian approach in the presentation of the uncertainty of the estimated dose in cases of exposure to low dose radiation

    International Nuclear Information System (INIS)

    Di Giorgio, Marina; Zaretzky, A.

    2010-01-01

    Biodosimetry laboratory experience has shown that there are limitations in the existing statistical methodology. Statistical difficulties generally occur due to the low number of aberrations leading to large uncertainties for dose estimation. Some problems derived from limitations of the classical statistical methodology, which requires that chromosome aberration yields be considered as something fixed and consequently provides a deterministic dose estimation and associated confidence limits. On the other hand, recipients of biological dosimetry reports, including medical doctors, regulators and the patients themselves may have a limited comprehension of statistics and of informed reports. Thus, the objective of the present paper is to use a Bayesian approach to present the uncertainty on the estimated dose to which a person could be exposed, in the case of low dose (occupational doses) radiation exposure. Such methodology will allow the biodosimetrists to adopt a probabilistic approach for the cytogenetic data analysis. At present, classical statistics allows to produce a confidence interval to report such dose, with a lower limit that could not detach from zero. In this situation it becomes difficult to make decisions as they could impact on the labor activities of the worker if an exposure exceeding the occupational dose limits is inferred. The proposed Bayesian approach is applied to occupational exposure scenario to contribute to take the appropriate radiation protection measures. (authors) [es

  17. Simple Calculation Programs for Biology Methods in Molecular ...

    Indian Academy of Sciences (India)

    First page Back Continue Last page Overview Graphics. Simple Calculation Programs for Biology Methods in Molecular Biology. GMAP: A program for mapping potential restriction sites. RE sites in ambiguous and non-ambiguous DNA sequence; Minimum number of silent mutations required for introducing a RE sites; Set ...

  18. Biodosimetry versus physical dosimetry for emergency dose assessment following large-scale radiological exposures

    International Nuclear Information System (INIS)

    McKeever, S.W.S.; Sholom, S.

    2016-01-01

    Existing data on intercomparisons involving biodosimetry or physical dosimetry methods are analyzed and the results interpreted regarding their efficacy in triage in emergency dosimetry following mass casualty radiological events. The biodosimetry technique examined is dicentric chromosome aberrations (DCA). The physical dosimetry techniques include electron paramagnetic resonance (EPR) of biological material (teeth) and physical material (smartphone screen glass), and optically stimulated luminescence (OSL) of electronic components (surface mount resistors) from mobile phones. Issues relating to calibration and interpretation of the data are discussed. An important conclusion of the analysis is that more research is critically needed to interpret the efficacy of the various methods. Included in this needed research are intercomparisons of the various methods in controlled experiments and the need to harmonize protocols. - Highlights: • Utility of bio- and physical dosimetry methods for emergency dosimetry triage. • Analysis of intercomparison data for different bio- and physical dosimetry methods. • The percentage of false positives and false negatives for a simulated IND event. • More research, especially intercomparisons, is required to reduce uncertainties.

  19. Calibration methods of plane-parallel ionization chambers used in electron dosimetry; Metodos de calibracao de camaras de ionizacao de placas paralelas para dosimetria de feixes de eletrons

    Energy Technology Data Exchange (ETDEWEB)

    Bulla, Roseli Tadeu

    1999-07-01

    The use of linear accelerators in radiotherapy is of great importance in Medicine, and according to international recommendations the electron beam dosimetry has to be performed using plane-parallel ionization chambers, previously calibrated in standard gamma radiation fields at accredited laboratories. In this work, calibration methods of plane-parallel ionization chambers used in dosimetry procedures of high energy electron beams of clinical accelerators were presented, tested and intercompared. The experiments were carried out using gamma radiation beams of {sup 60} Co at the Calibration Laboratory of Clinical Dosemeters at IPEN and electron beams od 4 to 16 MeV at the Radiotherapy Department of Hospital Israelita Albert Einstein, Sao Paulo. A method was chosen to be established at IPEN. Proposals of the calibration procedure, calibration certificate and data sheets are presented. (author)

  20. Bio-dosimetry of ionizing radiation

    International Nuclear Information System (INIS)

    Hadjidekova, V.; Kristova, R.; Stainova, A.; Deleva, S.; Popova, L.; Georgieva, D.

    2013-01-01

    Full text: Introduction: The impact of ionizing radiation in medical, occupational and accidental human exposure leads to adverse side effects such as increased mortality and carcinogenesis. Information about the level of absorbed dose is important for risk assessment and for implementation of appropriate therapy. In most cases of actual or suspected exposure to ionizing radiation biological dosimetry is the only way to assess the absorbed dose. What you will learn: In this work we discuss the methods for biodosimetry and technological developments in their application in various emergency situations. The application of biological dosimetry and assessment of the influence of external factors in the conduct of epidemiological studies of radiation effects in protracted low-dose ionizing radiation on humans is presented. Discussion: The results of cytogenetic analysis and biological evaluation of absorbed dose based on the analysis of dicentrics in peripheral blood lymphocytes of five people injured in a severe radiation accident in Bulgaria in 2011 are presented. The assessed individual doses of the injured persons are in the range of 1.2 to 5,2 Gy acute homogeneous irradiation and are in line with the estimates of international experts. Conclusion: An algorithm to conduct a biological assessment of the dose in limited radiation accidents and in large scale radiation accidents with large number irradiated or suspected for exposure persons is proposed

  1. Neutron personnel dosimetry

    International Nuclear Information System (INIS)

    Griffith, R.V.

    1981-01-01

    The current state-of-the-art in neutron personnel dosimetry is reviewed. Topics covered include dosimetry needs and alternatives, current dosimetry approaches, personnel monitoring devices, calibration strategies, and future developments

  2. Standardization of the Fricke gel dosimetry method and tridimensional dose evaluation using the magnetic resonance imaging technique

    International Nuclear Information System (INIS)

    Cavinato, Christianne Cobello

    2009-01-01

    This study standardized the method for obtaining the Fricke gel solution developed at IPEN. The results for different gel qualities used in the preparation of solutions and the influence of the gelatin concentration in the response of dosimetric solutions were compared. Type tests such as: dose response dependence, minimum and maximum detection limits, response reproducibility, among others, were carried out using different radiation types and the Optical Absorption (OA) spectrophotometry and Magnetic Resonance (MR) techniques. The useful dose ranges for Co 60 gamma radiation and 6 MeV photons are 0,4 to 30,0 Gy and 0,5 to 100,0 Gy , using OA and MR techniques, respectively. A study of ferric ions diffusion in solution was performed to determine the optimum time interval between irradiation and samples evaluation; until 2,5 hours after irradiation to obtain sharp MR images. A spherical simulator consisting of Fricke gel solution prepared with 5% by weight 270 Bloom gelatine (national quality) was developed to be used to three-dimensional dose assessment using the Magnetic Resonance Imaging (MRI) technique. The Fricke gel solution prepared with 270 Bloom gelatine, that, in addition to low cost, can be easily acquired on the national market, presents satisfactory results on the ease of handling, sensitivity, response reproducibility and consistency. The results confirm their applicability in the three-dimensional dosimetry using MRI technique. (author)

  3. Dosimetry in radiotherapy using a-Si EPIDs: Systems, methods, and applications focusing on 3D patient dose estimation

    Science.gov (United States)

    McCurdy, B. M. C.

    2013-06-01

    An overview is provided of the use of amorphous silicon electronic portal imaging devices (EPIDs) for dosimetric purposes in radiation therapy, focusing on 3D patient dose estimation. EPIDs were originally developed to provide on-treatment radiological imaging to assist with patient setup, but there has also been a natural interest in using them as dosimeters since they use the megavoltage therapy beam to form images. The current generation of clinically available EPID technology, amorphous-silicon (a-Si) flat panel imagers, possess many characteristics that make them much better suited to dosimetric applications than earlier EPID technologies. Features such as linearity with dose/dose rate, high spatial resolution, realtime capability, minimal optical glare, and digital operation combine with the convenience of a compact, retractable detector system directly mounted on the linear accelerator to provide a system that is well-suited to dosimetric applications. This review will discuss clinically available a-Si EPID systems, highlighting dosimetric characteristics and remaining limitations. Methods for using EPIDs in dosimetry applications will be discussed. Dosimetric applications using a-Si EPIDs to estimate three-dimensional dose in the patient during treatment will be overviewed. Clinics throughout the world are implementing increasingly complex treatments such as dynamic intensity modulated radiation therapy and volumetric modulated arc therapy, as well as specialized treatment techniques using large doses per fraction and short treatment courses (ie. hypofractionation and stereotactic radiosurgery). These factors drive the continued strong interest in using EPIDs as dosimeters for patient treatment verification.

  4. Skin dosimetry - radiological protection aspects of skin dosimetry

    International Nuclear Information System (INIS)

    Dennis, J.A.

    1991-01-01

    Following a Workshop in Skin Dosimetry, a summary of the radiological protection aspects is given. Aspects discussed include routine skin monitoring and dose limits, the need for careful skin dosimetry in high accidental exposures, techniques for assessing skin dose at all relevant depths and the specification of dose quantities to be measured by personal dosemeters and the appropriate methods to be used in their calibration. (UK)

  5. UNCERTAINTY ON RADIATION DOSES ESTIMATED BY BIOLOGICAL AND RETROSPECTIVE PHYSICAL METHODS.

    Science.gov (United States)

    Ainsbury, Elizabeth A; Samaga, Daniel; Della Monaca, Sara; Marrale, Maurizio; Bassinet, Celine; Burbidge, Christopher I; Correcher, Virgilio; Discher, Michael; Eakins, Jon; Fattibene, Paola; Güçlü, Inci; Higueras, Manuel; Lund, Eva; Maltar-Strmecki, Nadica; McKeever, Stephen; Rääf, Christopher L; Sholom, Sergey; Veronese, Ivan; Wieser, Albrecht; Woda, Clemens; Trompier, Francois

    2018-03-01

    Biological and physical retrospective dosimetry are recognised as key techniques to provide individual estimates of dose following unplanned exposures to ionising radiation. Whilst there has been a relatively large amount of recent development in the biological and physical procedures, development of statistical analysis techniques has failed to keep pace. The aim of this paper is to review the current state of the art in uncertainty analysis techniques across the 'EURADOS Working Group 10-Retrospective dosimetry' members, to give concrete examples of implementation of the techniques recommended in the international standards, and to further promote the use of Monte Carlo techniques to support characterisation of uncertainties. It is concluded that sufficient techniques are available and in use by most laboratories for acute, whole body exposures to highly penetrating radiation, but further work will be required to ensure that statistical analysis is always wholly sufficient for the more complex exposure scenarios.

  6. Biological dosimetry to determine the UV radiation climate inside the MIR station and its role in vitamin D biosynthesis

    Science.gov (United States)

    Rettberg, P.; Horneck, G.; Zittermann, A.; Heer, M.

    1998-11-01

    The vitamin D synthesis in the human skin, is absolutely dependent on UVB radiation. Natural UVB from sunlight is normally absent in the closed environment of a space station like MIR. Therefore it was necessary to investigate the UV radiation climate inside the station resulting from different lamps as well as from occasional solar irradiation behind a UV-transparent quartz window. Biofilms, biologically weighting and integrating UV dosimeters successfully applied on Earth (e.g. in Antarctica) and in space (D-2, Biopan I) were used to determine the biological effectiveness of the UV radiation climate at different locations in the space station. Biofilms were also used to determine the personal UV dose of an individual cosmonaut. These UV data were correlated with the concentration of vitamin D in the cosmonaut's blood and the dietary vitamin D intake. The results showed that the UV radiation climate inside the Mir station is not sufficient for an adequate supply of vitamin D, which should therefore be secured either by vitamin D supplementat and/or by the regular exposure to special UV lamps like those in sun-beds. The use of natural solar UV radiation through the quartz window for `sunbathing' is dangerous and should be avoided even for short exposure periods.

  7. Hematological dosimetry

    International Nuclear Information System (INIS)

    Fluery-Herard, A.

    1991-01-01

    The principles of hematological dosimetry after acute or protracted whole-body irradiation are reviewed. In both cases, over-exposure is never homogeneous and the clinical consequences, viz medullary aplasia, are directly associated with the mean absorbed dose and the seriousness and location of the overexposure. The main hematological data required to assess the seriousness of exposure are the following: repeated blood analysis, blood precursor cultures, as indicators of whole-body exposure; bone marrow puncture, medullary precursor cultures and medullary scintigraphy as indicators of the importance of a local over-exposure and capacity for spontaneous repair. These paraclinical investigations, which are essential for diagnosis and dosimetry, are also used for surveillance and for the main therapeutic issues [fr

  8. Personal radon daughter dosimetry

    International Nuclear Information System (INIS)

    Stocker, H.

    1979-12-01

    The conventional means of radon daughter exposure estimatikn for uranium miners in Canada is by grab sampling and time weighting. Personal dosimetry is a possible alternative method with its own advantages and limitations. The author poses basic questions with regard to two methods of radon daughter detection, thermoluminescent chips and track-etch film. An historical review of previous and current research and development programs in Canada and in other countries is presented, as are brief results and conclusions of each dosimeter evaluation

  9. Developments in physical dosimetry and radiation protection; Entwicklungen in der physikalischen Dosimetrie im Strahlenschutz

    Energy Technology Data Exchange (ETDEWEB)

    Fiebich, Martin [Technische Hochschule Mittelhessen, Giessen (Germany). Inst. fuer Medizinische Physik und Strahlenschutz

    2017-07-01

    In the frame of physical dosimetry new dose units have been defined: the depth personal dose (equivalent dose in 10 mm depth) and the surface personal dose (equivalent dose in 0.07 mm depth). Physical dosimetry is applied for the determination of occupational radiation exposure, the radiation protected area control, the estimation of radiation exposure of patients during radiotherapy, for quality assurance and in research projects and optimization challenges. Developments have appeared with respect to punctual measuring chambers, eye lens dosimetry, OSL (optically stimulated luminescence) dosimetry, real-time dosimetry and Monte Carlo methods. New detection limits of about 1 micro Gy were reached.

  10. Dosimetry in dentistry.

    Science.gov (United States)

    Asha, M L; Chatterjee, Ingita; Patil, Preeti; Naveen, S

    2015-01-01

    The purpose of this paper was to review various dosimeters used in dentistry and the cumulative results of various studies done with various dosimeters. Several relevant PubMed indexed articles from 1999 to 2013 were electronically searched by typing "dosimeters", "dosimeters in dentistry", "properties of dosimeters", "thermoluminescent and optically stimulated dosimeters", "recent advancements in dosimetry in dentistry." The searches were limited to articles in English to prepare a concise review on dental dosimetry. Titles and abstracts were screened, and articles that fulfilled the criteria of use of dosimeters in dental applications were selected for a full-text reading. Article was divided into four groups: (1) Biological effects of radiation, (2) properties of dosimeters, (3) types of dosimeters and (4) results of various studies using different dosimeters. The present review on dosimetry based on various studies done with dosimeters revealed that, with the advent of radiographic technique the effective dose delivered is low. Therefore, selection of radiological technique plays an important role in dental dose delivery.

  11. Optimization of the preparation method of LiF: Mg, Cu, P and study of its thermoluminescent properties to be used in ionizing radiation dosimetry

    International Nuclear Information System (INIS)

    Gonzalez M, P.R.

    1995-01-01

    In this thesis the preparation and dosimetric properties of the thermoluminescence phosphor LiF doped with magnesium, copper and phosphorus are studied. In chapter 1 luminescence phenomenon in solids is described, emphasizing the importance of thermally stimulated luminescence known as thermoluminescence (TL) as well as its application in ionizing radiation dosimetry. The models used to determine the kinetics parameters in the TL phenomenon are described in chapter 2. In chapter 3, the dosimetric characteristics of a TL materials and its requirements for dosimetry are analyzed. The preparation method of LiF: Mg, Cu, P is presented in chapter 4 studying its general characteristics for dosimetry. The concentrations of dopants, glow curve structure, TL response to gamma, beta and alpha exposures are studied along with those of LiF: Mg, Cu, P prepared for other authors and with those of LiF: Mg, Ti (TLD-100). The kinetic parameters of the phosphor were determined by the deconvolution method. Pellets of this new phosphor powder were made by pressing it at room temperature and sintering in inert atmosphere at 700 Centigrade degrees. Dosimetric characteristics of these pellets were also studied. Chapter 5 presents the results and conclusions of this study. The new dosimeter exhibited three peaks in its glow curve at 140, 180 and 220 Centigrade degrees respectively. Its TL response to gamma radiation was linear from 43.5 μ Gy to 100 Gy. This dosimeter is reusable and stable without significant loss of sensitivity. Its sensitivity was about 30 times higher than that of TLD-100. Fading of this dosimeter was negligible at room temperature as well as at body temperature (37 Centigrade degrees), and 65% at 60 Centigrade degrees. In conclusion, this dosimeter meets all the requirements of the ANSI standard. These and other characteristics render this dosimeter useful in diverse applications of radiation dosimetry. (Author)

  12. Amylase and blood cell-count hematological radiation-injury biomarkers in a rhesus monkey radiation model-use of multiparameter and integrated biological dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Blakely, W.F. [Uniformed Services University, Armed Forces Radiobiology Research Institute, 8901 Wisconsin Avenue, Bethesda, MD 20889-5603 (United States)], E-mail: blakely@afrri.usuhs.mil; Ossetrova, N.I.; Manglapus, G.L.; Salter, C.A.; Levine, I.H.; Jackson, W.E.; Grace, M.B.; Prasanna, P.G.S.; Sandgren, D.J.; Ledney, G.D. [Uniformed Services University, Armed Forces Radiobiology Research Institute, 8901 Wisconsin Avenue, Bethesda, MD 20889-5603 (United States)

    2007-07-15

    Effective medical management of suspected radiation exposure incidents requires the recording of dynamic medical data (clinical signs and symptoms), biological assessments of radiation exposure, and physical dosimetry in order to provide diagnostic information to the treating physician and dose assessment for personnel radiation protection records. The need to rapidly assess radiation dose in mass-casualty and population-monitoring scenarios prompted an evaluation of suitable biomarkers that can provide early diagnostic information after exposure. We investigated the utility of serum amylase and hematological blood-cell count biomarkers to provide early assessment of severe radiation exposures in a non-human primate model (i.e., rhesus macaques; n=8) exposed to whole-body radiation of {sup 60}Co-gamma rays (6.5 Gy, 40cGymin{sup -1}). Serum amylase activity was significantly elevated (12.3{+-}3.27- and 2.6{+-}0.058-fold of day zero samples) at 1 and 2-days, respectively, after radiation. Lymphocyte cell counts decreased ({<=}15% of day zero samples) 1 and 2 days after radiation exposure. Neutrophil cell counts increased at day one by 1.9({+-}0.38)-fold compared with levels before irradiation. The ratios of neutrophil to lymphocyte cell counts increased by 13({+-}2.66)- and 4.23({+-}0.95)-fold at 1 and 2 days, respectively, after irradiation. These results demonstrate that increases in serum amylase activity along with decreases of lymphocyte counts, increases in neutrophil cell counts, and increases in the ratio of neutrophil to lymphocyte counts 1 day after irradiation can provide enhanced early triage discrimination of individuals with severe radiation exposure and injury. Use of the biodosimetry assessment tool (BAT) application is encouraged to permit dynamic recording of medical data in the management of a suspected radiological casualty.

  13. Particle transport methods for LWR dosimetry developed by the Penn State transport theory group

    International Nuclear Information System (INIS)

    Haghighat, A.; Petrovic, B.

    1997-01-01

    This paper reviews advanced particle transport theory methods developed by the Penn State Transport Theory Group (PSTTG) over the past several years. These methods have been developed in response to increasing needs for accuracy of results and for three-dimensional modeling of nuclear systems

  14. Use of the finite-difference time-domain method in electromagnetic dosimetry

    International Nuclear Information System (INIS)

    Sullivan, D.M.

    1987-01-01

    Although there are acceptable methods for calculating whole body electromagnetic absorption, no completely acceptable method for calculating the local specific absorption rate (SAR) at points within the body has been developed. Frequency domain methods, such as the method of moments (MoM) have achieved some success; however, the MoM requires computer storage on the order of (3N) 2 , and computation time on the order of (3N) 3 where N is the number of cells. The finite-difference time-domain (FDTD) method has been employed extensively in calculating the scattering from metallic objects, and recently is seeing some use in calculating the interaction of EM fields with complex, lossy dielectric bodies. Since the FDTD method has storage and time requirements proportional to N, it presents an attractive alternative to calculating SAR distribution in large bodies. This dissertation describes the FDTD method and evaluates it by comparing its results with analytic solutions in 2 and 3 dimensions. The results obtained demonstrate that the FDTD method is capable of calculating internal SAR distribution with acceptable accuracy. The construction of a data base to provide detailed, inhomogeneous man models for use with the FDTD method is described. Using this construction method, a model of 40,000 1.31 cm. cells is developed for use at 350 MHz, and another model consisting of 5000 2.62 cm. cells is developed for use at 100 MHz. To add more realism to the problem, a ground plane is added to the FDTD software. The needed changes to the software are described, along with a test which confirms its accuracy. Using the CRAY II supercomputer, SAR distributions in human models are calculated using incident frequencies of 100 MHz and 350 MHz for three different cases: (1) A homogeneous man model in free space, (2) an inhomogeneous man model in free space, and (3) an inhomogeneous man model standing on a ground plane

  15. Biostatistical methods [Methods in molecular biology, v. 184

    National Research Council Canada - National Science Library

    Looney, Steven W

    2002-01-01

    .... In the case of genetic effects in human populations, the authors describe sophisticated statistical methods to control the overall false-positive rate when many statistical tests are used in linking...

  16. A practical procedure to improve the accuracy of radiochromic film dosimetry. A integration with a correction method of uniformity correction and a red/blue correction method

    International Nuclear Information System (INIS)

    Uehara, Ryuzo; Tachibana, Hidenobu; Ito, Yasushi; Yoshino, Shinichi; Matsubayashi, Fumiyasu; Sato, Tomoharu

    2013-01-01

    It has been reported that the light scattering could worsen the accuracy of dose distribution measurement using a radiochromic film. The purpose of this study was to investigate the accuracy of two different films, EDR2 and EBT2, as film dosimetry tools. The effectiveness of a correction method for the non-uniformity caused from EBT2 film and the light scattering was also evaluated. In addition the efficacy of this correction method integrated with the red/blue correction method was assessed. EDR2 and EBT2 films were read using a flatbed charge-coupled device scanner (EPSON 10000 G). Dose differences on the axis perpendicular to the scanner lamp movement axis were within 1% with EDR2, but exceeded 3% (Maximum: +8%) with EBT2. The non-uniformity correction method, after a single film exposure, was applied to the readout of the films. A corrected dose distribution data was subsequently created. The correction method showed more than 10%-better pass ratios in dose difference evaluation than when the correction method was not applied. The red/blue correction method resulted in 5%-improvement compared with the standard procedure that employed red color only. The correction method with EBT2 proved to be able to rapidly correct non-uniformity, and has potential for routine clinical intensity modulated radiation therapy (IMRT) dose verification if the accuracy of EBT2 is required to be similar to that of EDR2. The use of red/blue correction method may improve the accuracy, but we recommend we should use the red/blue correction method carefully and understand the characteristics of EBT2 for red color only and the red/blue correction method. (author)

  17. [A practical procedure to improve the accuracy of radiochromic film dosimetry: a integration with a correction method of uniformity correction and a red/blue correction method].

    Science.gov (United States)

    Uehara, Ryuzo; Tachibana, Hidenobu; Ito, Yasushi; Yoshino, Shinichi; Matsubayashi, Fumiyasu; Sato, Tomoharu

    2013-06-01

    It has been reported that the light scattering could worsen the accuracy of dose distribution measurement using a radiochromic film. The purpose of this study was to investigate the accuracy of two different films, EDR2 and EBT2, as film dosimetry tools. The effectiveness of a correction method for the non-uniformity caused from EBT2 film and the light scattering was also evaluated. In addition the efficacy of this correction method integrated with the red/blue correction method was assessed. EDR2 and EBT2 films were read using a flatbed charge-coupled device scanner (EPSON 10000G). Dose differences on the axis perpendicular to the scanner lamp movement axis were within 1% with EDR2, but exceeded 3% (Maximum: +8%) with EBT2. The non-uniformity correction method, after a single film exposure, was applied to the readout of the films. A corrected dose distribution data was subsequently created. The correction method showed more than 10%-better pass ratios in dose difference evaluation than when the correction method was not applied. The red/blue correction method resulted in 5%-improvement compared with the standard procedure that employed red color only. The correction method with EBT2 proved to be able to rapidly correct non-uniformity, and has potential for routine clinical IMRT dose verification if the accuracy of EBT2 is required to be similar to that of EDR2. The use of red/blue correction method may improve the accuracy, but we recommend we should use the red/blue correction method carefully and understand the characteristics of EBT2 for red color only and the red/blue correction method.

  18. Assessment of necessary regularity of internal irradiation monitoring on the basis of direct and indirect methods of dosimetry

    International Nuclear Information System (INIS)

    Malykhin, V.M.; Ivanova, N.I.

    1981-01-01

    It is shown that when assessing the necessary periodicity of internal irradiation monitoring, it is required to take account of the nature (rhythm) of radionuclide intake to the organism during the monitoring period, the effective period of radionuclide biological half-life, its activity in the organism, sensitivity of the technique applied and the labour-consumig character of the monitoring method [ru

  19. Hanford External Dosimetry Program

    International Nuclear Information System (INIS)

    Fix, J.J.

    1990-10-01

    This document describes the Hanford External Dosimetry Program as it is administered by Pacific Northwest Laboratory (PNL) in support of the US Department of Energy (DOE) and its Hanford contractors. Program services include administrating the Hanford personnel dosimeter processing program and ensuring that the related dosimeter data accurately reflect occupational dose received by Hanford personnel or visitors. Specific chapters of this report deal with the following subjects: personnel dosimetry organizations at Hanford and the associated DOE and contractor exposure guidelines; types, characteristics, and procurement of personnel dosimeters used at Hanford; personnel dosimeter identification, acceptance testing, accountability, and exchange; dosimeter processing and data recording practices; standard sources, calibration factors, and calibration processes (including algorithms) used for calibrating Hanford personnel dosimeters; system operating parameters required for assurance of dosimeter processing quality control; special dose evaluation methods applied for individuals under abnormal circumstances (i.e., lost results, etc.); and methods for evaluating personnel doses from nuclear accidents. 1 ref., 14 figs., 5 tabs

  20. Basic theory and methods of dosimetry for use in risk assessment of genotoxic chemicals

    Energy Technology Data Exchange (ETDEWEB)

    Ehrenberg, L; Granath, F

    1992-01-01

    This project is designed to be theoretical, with limited experimental input. The work then would have to be directed towards an identification of problems, with an emphasis on the potential ability of molecular/biochemical methods to reach a solution, rather than aiming at solutions of the problems. In addition, the work is dependent on experimental work within parallel projects. Initially, projects running at this laboratory were strongly tied up with practical matters, such as the development of monitoring methods for specific exposures, with limited resources for basic research. As sketched in the scientific report below, section 4 the meaningfulness of molecular/biochemical methods and their potential contribution to the problem of dsk estimation has to be seen against a broad overview of this problem and current efforts to solve it. This overview, given as a brief summary in section 3, shows the necessity of combining different fields of research, holding them together by strictly quantitative aspects.

  1. Preparation of CaSO4:Dy by precipitation method to gamma radiation dosimetry

    International Nuclear Information System (INIS)

    Rivera, T.; Roman, J.; Azorin, J.; Sosa, R.; Guzman, J.; Serrano, A.K.; Garcia, M.; Alarcon, G.

    2010-01-01

    This paper presents the results of the preparation and characterization of dysprosium-doped calcium sulfate (CaSO 4 :Dy) phosphor, which was obtained by homogeneous precipitation from calcium acetate Ca(CH 3 COO - ) 2 . Structural and morphological characteristics were studied using a scanning electronic microscope (SEM). The structure of all compounds was determined by X-ray diffraction method too. Thermoluminescence (TL) emission properties of CaSO 4 :Dy under gamma radiation effects were studied. This phosphor powder presented a TL glow curve with two peaks (Tmax) centered at around of 180 and 300 deg. C, respectively. The TL response of CaSO 4 :Dy as a function of gamma absorbed dose was linear in a wide range. Both emission and excitation spectra were also obtained. Results showed that this new preparation method of CaSO 4 :Dy TL phosphor is less expensive, cleaner and safer than the conventional preparation method.

  2. Dosimetry of fast neutrons

    International Nuclear Information System (INIS)

    Jahr, R.

    1975-03-01

    Following an explanation of the physical fundamentals of neutron dosimetry, the special needs in medicine and biology are gone into. It is shown that the dose equivalent used in radiation protection simplifies in an undue manner the complicated dependence of the biological effects. The reason for this is the fact that the RBE for heavy recoil nuclei, amongst others, depends on the energy and sort of particle, whereas it is approximately equal to one for electrons independent of the energy. It is thus necessary in the fields of biology and medicine to have additional information on energy spectra of the neutrons as well as of all charged secondary particles as a function of the position in the phantom. These are obtained partly by calculation and partly by special dosemeters. The accuracy achieved so far is 5%. (ORU/LH) [de

  3. A calibration method for realistic neutron dosimetry in radiobiological experiments assisted by MCNP simulation.

    Science.gov (United States)

    Shahmohammadi Beni, Mehrdad; Krstic, Dragana; Nikezic, Dragoslav; Yu, Kwan Ngok

    2016-09-01

    Many studies on biological effects of neutrons involve dose responses of neutrons, which rely on accurately determined absorbed doses in the irradiated cells or living organisms. Absorbed doses are difficult to measure, and are commonly surrogated with doses measured using separate detectors. The present work describes the determination of doses absorbed in the cell layer underneath a medium column (D A ) and the doses absorbed in an ionization chamber (D E ) from neutrons through computer simulations using the MCNP-5 code, and the subsequent determination of the conversion coefficients R (= D A /D E ). It was found that R in general decreased with increase in the medium thickness, which was due to elastic and inelastic scattering. For 2-MeV neutrons, conspicuous bulges in R values were observed at medium thicknesses of about 500, 1500, 2500 and 4000 μm, and these were attributed to carbon, oxygen and nitrogen nuclei, and were reflections of spikes in neutron interaction cross sections with these nuclei. For 0.1-MeV neutrons, no conspicuous bulges in R were observed (except one at ~2000 μm that was due to photon interactions), which was explained by the absence of prominent spikes in the interaction cross-sections with these nuclei for neutron energies <0.1 MeV. The ratio R could be increased by ~50% for small medium thickness if the incident neutron energy was reduced from 2 MeV to 0.1 MeV. As such, the absorbed doses in cells (D A ) would vary with the incident neutron energies, even when the absorbed doses shown on the detector were the same. © The Author 2016. Published by Oxford University Press on behalf of The Japan Radiation Research Society and Japanese Society for Radiation Oncology.

  4. Dosimetry for Crystals Irradiation

    CERN Document Server

    Lecomte, Pierre

    2005-01-01

    Before shipment to CMS, all PbWO4 crystals produced in China are irradiated there with 60 Co , in order to insure that the induced absorption coefficient is within specifications. Acceptance tests at CERNand at ENEA also include irradiation with gamma rays from 60 Co sources. There were initially discrepancies in quoted doses and doserates as well as in induced absorption coefficients. The present work resolves the discrepancies in irradiation measurements and defines common dosimetry methods for consistency checks between irradiation facilities.

  5. Radiation dosimetry for residents of the Chernobyl region: a comparison of cytogenetic and electron spin resonance methods

    Energy Technology Data Exchange (ETDEWEB)

    Serezhenkov, V A; Mordvintcev, P I; Vanin, A F; Voevodskaya, N V [AN SSSR, Moscow (Russian Federation). Inst. Fizicheskoj Khimii; Domracheva, E V; Kulikov, S M; Kuznetsov, S A; Schklovsky-Kordi, N E; Vorobiev, A I [National Center for Haematology, Moscow (Russian Federation); Klevezal, G A; Sukhovskaya, L I [Russian Academy of Science, Moscow (Russian Federation). Inst. of Developmental Biology

    1992-01-01

    Persons from the Gomel region of Byelorussia who were irradiated by the Chernobyl reactor accident have been studied. Estimations of their radiation doses using electron spin resonance spectrometry of dental enamel showed good agreement with dosimetry by chromosomal analysis of blood lymphocytes. (author).

  6. Study of a method based on TLD detectors for in-phantom dosimetry in BNCT

    Energy Technology Data Exchange (ETDEWEB)

    Gambarini, G. [Dept. of Physics of the Univ., Via Celoria 16, 20133 Milan (Italy); INFN, Natl. Inst. of Nuclear Physics, Via Celoria 16, 20133 Milan (Italy); Klamert, V. [Dept. of Nuclear Eng. of Polytechnic, CESNEF, Via Ponzio 34/3, 20133 Milan (Italy); Agosteo, S. [INFN, Natl. Inst. of Nuclear Physics, Via Celoria 16, 20133 Milan (Italy); Dept. of Nuclear Eng. of Polytechnic, CESNEF, Via Ponzio 34/3, 20133 Milan (Italy); Birattari, C.; Gay, S. [Dept. of Physics of the Univ., Via Celoria 16, 20133 Milan (Italy); INFN, Natl. Inst. of Nuclear Physics, Via Celoria 16, 20133 Milan (Italy); Rosi, G. [FIS-ION, ENEA, Casaccia, Via Anguillarese 301, 00060 Santa Maria di Galeria, Rome (Italy); Scolari, L. [Dept. of Physics of the Univ., Via Celoria 16, 20133 Milan (Italy); INFN, Natl. Inst. of Nuclear Physics, Via Celoria 16, 20133 Milan (Italy)

    2004-07-01

    A method has been developed, based on thermoluminescent dosemeters (TLD), aimed at measuring the absorbed dose in tissue-equivalent phantoms exposed to thermal or epithermal neutrons, separating the contributions of various secondary radiation generated by neutrons. The proposed method takes advantage of the very low sensitivity of CaF{sub 2}:Tm (TLD-300) to low energy neutrons and to the different responses to thermal neutrons of LiF:Mg,Ti dosemeters with different {sup 6}Li percentage (TLD-100, TLD-700, TLD-600). The comparison of the results with those obtained by means of gel dosemeters and activation foils has confirmed the reliability of the method. The experimental modalities allowing reliable results have been studied. The glow curves of TLD-300 after gamma or neutron irradiation have been compared; moreover, both internal irradiation effect and energy dependence have been investigated. For TLD-600, TLD-100 and TLD-700, the suitable fluence limits have been determined in order to avoid radiation damage and loss of linearity. (authors)

  7. Neutron Dosimetry

    International Nuclear Information System (INIS)

    Vanhavere, F.

    2001-01-01

    The objective of SCK-CEN's R and D programme on neutron dosimetry is to improve the determination of neutron doses by studying neutron spectra, neutron dosemeters and shielding adaptations. In 2000, R and D focused on the contiued investigation of the bubble detectors type BD-PND and BDT, in particular their sensitivity and temperature dependence; the updating of SCK-CEN's criticality dosemeter, the investigation of the characteristics of new thermoluminescent materials and their use in neutron dosemetry; and the investigation of neutron shielding

  8. Neutron Dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Vanhavere, F

    2001-04-01

    The objective of SCK-CEN's R and D programme on neutron dosimetry is to improve the determination of neutron doses by studying neutron spectra, neutron dosemeters and shielding adaptations. In 2000, R and D focused on the contiued investigation of the bubble detectors type BD-PND and BDT, in particular their sensitivity and temperature dependence; the updating of SCK-CEN's criticality dosemeter, the investigation of the characteristics of new thermoluminescent materials and their use in neutron dosemetry; and the investigation of neutron shielding.

  9. The incidence of the different sources of noise on the uncertainty in radiochromic film dosimetry using single channel and multichannel methods

    Science.gov (United States)

    González-López, Antonio; Vera-Sánchez, Juan Antonio; Ruiz-Morales, Carmen

    2017-11-01

    The influence of the various sources of noise on the uncertainty in radiochromic film (RCF) dosimetry using single channel and multichannel methods is investigated in this work. These sources of noise are extracted from pixel value (PV) readings and dose maps. Pieces of an RCF were each irradiated to different uniform doses, ranging from 0 to 1092 cGy. Then, the pieces were read at two resolutions (72 and 150 ppp) with two flatbed scanners: Epson 10000XL and Epson V800, representing two states of technology. Noise was extracted as described in ISO 15739 (2013), separating its distinct constituents: random noise and fixed pattern (FP) noise. Regarding the PV maps, FP noise is the main source of noise for both models of digitizer. Also, the standard deviation of the random noise in the 10000XL model is almost twice that of the V800 model. In the dose maps, the FP noise is smaller in the multichannel method than in the single channel ones. However, random noise is higher in this method, throughout the dose range. In the multichannel method, FP noise is reduced, as a consequence of this method’s ability to eliminate channel independent perturbations. However, the random noise increases, because the dose is calculated as a linear combination of the doses obtained by the single channel methods. The values of the coefficients of this linear combination are obtained in the present study, and the root of the sum of their squares is shown to range between 0.9 and 1.9 over the dose range studied. These results indicate the random noise to play a fundamental role in the uncertainty of RCF dosimetry: low levels of random noise are required in the digitizer to fully exploit the advantages of the multichannel dosimetry method. This is particularly important for measuring high doses at high spatial resolutions.

  10. Fundamentals of Dosimetry. Chapter 3

    Energy Technology Data Exchange (ETDEWEB)

    Yoshimura, E. M. [Universidade de São Paulo, São Paulo (Brazil)

    2014-09-15

    Determination of the energy imparted to matter by radiation is the subject of dosimetry. The energy deposited as radiation interacts with atoms of the material, as seen in the previous chapter. The imparted energy is responsible for the effects that radiation causes in matter, for instance, a rise in temperature, or chemical or physical changes in the material properties. Several of the changes produced in matter by radiation are proportional to the absorbed dose, giving rise to the possibility of using the material as the sensitive part of a dosimeter. Also, the biological effects of radiation depend on the absorbed dose. A set of quantities related to the radiation field is also defined within the scope of dosimetry. It will be shown in this chapter that, under special conditions, there are simple relations between dosimetric and field description quantities. Thus, the framework of dosimetry is the set of physical and operational quantities that are studied in this chapter.

  11. Neutron generator (HIRRAC) and dosimetry study.

    Science.gov (United States)

    Endo, S; Hoshi, M; Takada, J; Tauchi, H; Matsuura, S; Takeoka, S; Kitagawa, K; Suga, S; Komatsu, K

    1999-12-01

    Dosimetry studies have been made for neutrons from a neutron generator at Hiroshima University (HIRRAC) which is designed for radiobiological research. Neutrons in an energy range from 0.07 to 2.7 MeV are available for biological irradiations. The produced neutron energies were measured and evaluated by a 3He-gas proportional counter. Energy spread was made certain to be small enough for radiobiological studies. Dose evaluations were performed by two different methods, namely use of tissue equivalent paired ionization chambers and activation of method with indium foils. Moreover, energy deposition spectra in small targets of tissue equivalent materials, so-called lineal energy spectrum, were also measured and are discussed. Specifications for biological irradiation are presented in terms of monoenergetic beam conditions, dose rates and deposited energy spectra.

  12. Topics in radiation dosimetry radiation dosimetry

    CERN Document Server

    1972-01-01

    Radiation Dosimetry, Supplement 1: Topics in Radiation Dosimetry covers instruments and techniques in dealing with special dosimetry problems. The book discusses thermoluminescence dosimetry in archeological dating; dosimetric applications of track etching; vacuum chambers of radiation measurement. The text also describes wall-less detectors in microdosimetry; dosimetry of low-energy X-rays; and the theory and general applicability of the gamma-ray theory of track effects to various systems. Dose equivalent determinations in neutron fields by means of moderator techniques; as well as developm

  13. Method validation to measure Strontium-90 in urine sample for internal dosimetry assessment

    International Nuclear Information System (INIS)

    Bitar, A.; Maghrabi, M.; Alhamwi, A.

    2010-12-01

    Occupational individuals exposed at some scientific centers in Syrian Arab Republic to potentially significant intake by ingestion or inhalation during process of producing radiopharmaceutical compounds. The received radioactive intake differs in relation to the amount of radionuclides released during the preparation processes, to the work conditions and to the applying ways of the radiation protection procedures. TLD (Thermoluminescence Dosimeter) is usually used for external radiation monitoring for workers in radioisotope centers. During the external monitoring programme, it was noticed that some workers were exposed to high external dose resultant from radiation accident in their laboratory when preparing Y-90 from Sr-90. For internal dose assessment, chemical method to measure the amount of Sr-90 in urine samples was validated and explained in details in this study. Urine bioassays were carried out and the activities of 90 Sr were determined using liquid scintillation counter. Then, the validated method was used for internal occupational monitoring purposes through the design of internal monitoring programme. The programme was established for four workers who are dealing, twice per month, with an amount of about 20 mCi in each time. At the beginning, theoretical study was done to assess maximum risks for workers. Calculated internal doses showed that it is necessary to apply internal routine monitoring programme for those workers. (author)

  14. Estimation of dose ionizing radiation exposure by biological dosimetry; Estimación de dosis de exposición a radiaciones ionizantes mediante dosimetría biológica

    Energy Technology Data Exchange (ETDEWEB)

    Herranz Crespo, R.; Moreno Domene, M.; Prieto Rodríguez, M.J.; Lozano Barriuso, M.A.

    2014-07-01

    the Biological Dosimetry Laboratory of the Radiopathology Centre, at Hospital General Universitario Gregorio Marañón, is the only national laboratory accredited by UNE-EN ISO/IEC 17025:2005, and scope to ISO 19238:2004 (Radiation protection – Performance criteria for service laboratories performing biological dosimetry by citogenetics), for dose assessment by the dycentrics assay, has great experience with more than 100 real cases analyzed, and several population studies. This paper describes experience and results from more than 20 years of work under the Reference level II Centre for the attention of irradiated and/or contaminated people. [Spanish] El Laboratorio de Dosimetría Biológica, del Centro de Radiopatología del Hospital General Universitario Gregorio Marañón, es el único en España que dispone de acreditación internacional por la norma UNE-EN ISO/IEC 17025:2005 con alcance a la norma ISO 19238:2004 (Radiationprotection – Performance criteria for service laboratories performing biological dosimetry by citogenetics), para la realización de estimaciones dosimétricas mediante la técnica de dicéntricos, dispone de amplia experiencia en su aplicación en los 110 casos reales analizados, y en diferentes estudios de poblaciones españolas. En este trabajo se describe la experiencia del laboratorio y los resultados obtenidos en los más de 20 años de funcionamiento en el Centro de Referencia de nivel II para la atención a irradiados y/o contaminados por radiaciones ionizantes.

  15. Retrospective accident dosimetry using trapped charges

    Energy Technology Data Exchange (ETDEWEB)

    Lee, J. I.; Kim, J. L.; Chang, I.; Kim, B. H. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-10-15

    Dicentric chromosome aberrations technique scoring of aberrations in metaphases prepared from human lymphocytes is most commonly used. This is considered as a reliable technique because the sample is extracted from the individual human body itself. There are other techniques in biological dosimetry such as Fluorescence In Situ Hybridization (FISH) using translocations, premature chromosome condensation (PCC) and micronucleus assay. However the minimum detectable doses (MDD) are relatively high and sample preparation time is also relatively longer. Therefore, there is limitation in use of these techniques for the purpose of triage in a short time in case of emergency situation relating large number of persons. Electronic paramagnetic resonance (EPR) technique is based on the signal from unpaired electrons such as free radicals in irradiated materials especially tooth enamel, however it has also limitation for the purpose of triage because of difficulty of sample taking and its high MDD. Recently as physical methods, thermoluminescence (TL) and optically stimulated luminescence (OSL) technique have been attracted due to its lower MDD and simplicity of sample preparation. Density of the trapped charges is generally proportional to the radiation dose absorbed and the intensity of emitting light is also proportional to the density of trapped charges, thus it can be applied to measure radiation dose retrospectively. In this presentation, TL and OSL techniques are going to introduced and discussed as physical methods for retrospective accident dosimetry using trapped charges especially in electronic component materials. As a tool for dose reconstruction for emergency situation, thermoluminescece and optically stimulated luminescence techniques which are based on trapped charges during exposure of material are introduced. These techniques have several advantages such as high sensitivity, fast evaluation and ease to sample collection over common biological dosimetry and EPR

  16. Advances in biomedical dosimetry

    International Nuclear Information System (INIS)

    1981-01-01

    Full text: Radiation dosimetry, the accurate determination of the absorbed dose within an irradiated body or a piece of material, is a prerequisite for all applications of ionizing radiation. This has been known since the very first radiation applications in medicine and biology, and increasing efforts are being made by radiation researchers to develop more reliable, effective and safe instruments, and to further improve dosimetric accuracy for all types of radiation used. Development of new techniques and instrumentation was particularly fast in the field of both medical diagnostic and therapeutic radiology. Thus, in Paris in October the IAEA held the latest symposium in its continuing series on dosimetry in medicine and biology. The last one was held in Vienna in 1975. High-quality dosimetry is obviously of great importance for human health, whether the objectives lie in the prevention and control of risks associated with the nuclear industry, in medical uses of radioactive substances or X-ray beams for diagnostic purposes, or in the application of photon, electron or neutron beams in radiotherapy. The symposium dealt with the following subjects: General aspects of dosimetry; Special physical and biomedical aspects; Determination of absorbed dose; Standardization and calibration of dosimetric systems; and Development of dosimetric systems. The forty or so papers presented and the discussions that followed them brought out a certain number of dominant themes, among which three deserve particular mention. - The recent generalization of the International System of Units having prompted a fundamental reassessment of the dosimetric quantities to be considered in calibrating measuring instruments, various proposals were advanced by the representatives of national metrology laboratories to replace the quantity 'exposure' (SI unit = coulomb/kg) by 'Kerma' or 'absorbed dose' (unit joule/kg, the special name of which is 'gray'), this latter being closer to the practical

  17. Electret ionization chamber: a new method for detection and dosimetry of thermal neutrons

    International Nuclear Information System (INIS)

    Ghilardi, A.J.P.

    1988-01-01

    An electret ionization chamber with boron coated walls is presented as a new method for detecting thermal neutrons. The efficiency of electret ionization chambers with different wall materials for the external electrode was inferred from the results. Detection of slow neutrons with discrimination against the detection of γ-rays and energetic neutrons was shown to depend on the selection of these materials. The charge stability over a long period of time and the charge decay owing to natural radiation were also studied. Numerical analysis was developed by the use of a micro-computer PC-XT. Both the experimental and numerical results show that the sensitivity of the electret ionization chamber for detection of thermal neutrons is comparable with that of the BF 3 ionization chamber and that new technologies for deposition of the boron layer will produce higher efficiency detectors. (author). 102 refs, 32 fig, 10 tabs

  18. Thermo-luminescent dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Reither, M; Schorn, B; Schneider, E

    1981-01-01

    The development of paediatric radiology which began in the late 195O's has been characterised by the need to limit the dose of ionising radiation to which the child is subjected. The aim has been to keep radiation exposure as low as possible by the introduction of suitable techniques and by the development of new methods. It is therefore surprising that studies in dosimetry in the paediaytric age range have only been carried out in recent years. One reason for this may have been the fact that a suitable technique of measurement was not available at the time. The introduction of solid state dosimetry based on thermo-luminescence, first into radiotherapy (1968) and subsequently into radiodiagnosis, has made it possible to abandon the previously widely used ionisation chamber. The purpose of the present paper is to indicate the suitability of this form of dose measurement for paediatric radiological purposes and to stimulate its application in this field.

  19. Legal aspects of dosimetry

    International Nuclear Information System (INIS)

    Pomarola, H.

    1976-01-01

    The use of ionizing radiations is regulated in France in all fields of application. The main principles governing inspection activities in the food industry are outlined. Conventional preservation methods are mentioned, after which a discussion is devoted to the preservation of food products by irradiation treatment and the increasing importance given to this technique. Consumer protection automatically implies the obligatory use of dosimetry by inspection organisms if the irradiated merchandise is likely to serve for human or animal consumption. Irradiation treatment permits are granted in a context of specific statutory texts mentioned here. Supervision is constant, but always both realistic and flexible. Each aspect of this treatment is discussed in maximum detail if not quite exhaustively, with special emphasis on dosimetry as an indispensable safety factor [fr

  20. Preparation, Biological Evaluation and Dosimetry Studies of 175Yb-Bis-Phosphonates for Palliative Treatment of Bone Pain

    Directory of Open Access Journals (Sweden)

    Ashraf Fakhari

    2015-10-01

    Full Text Available Objective: Optimized production and quality control of ytterbium-175 (Yb-175 labeled pamidronate and alendronate complexes as efficient agents for bone pain palliation has been presented. Methods: Yb-175 labeled pamidronate and alendronate (175Yb-PMD and 175Yb-ALN complexes were prepared successfully at optimized conditions with acceptable radiochemical purity, stability and significant hydroxyapatite absorption. The biodistribution of complexes were evaluated up to 48 h, which demonstrated significant bone uptake ratios for 175Yb-PAM at all-time intervals. It was also detected that 175Yb-PAM mostly washed out and excreted through the kidneys. Results: The performance of 175Yb-PAM in an animal model was better or comparable to other 175Yb-bone seeking complexes previously reported. Conclusion: Based on calculations, the total body dose for 175Yb-ALN is 40% higher as compared to 175Yb-PAM (especially kidneys indicating that 175Yb-PAM is probably a safer agent than 175Yb-ALN.

  1. Application of a practical method for the isocenter point in vivo dosimetry by a transit signal

    International Nuclear Information System (INIS)

    Piermattei, Angelo; Fidanzio, Andrea; Azario, Luigi

    2007-01-01

    This work reports the results of the application of a practical method to determine the in vivo dose at the isocenter point, D iso , of brain thorax and pelvic treatments using a transit signal S t . The use of a stable detector for the measurement of the signal S t (obtained by the x-ray beam transmitted through the patient) reduces many of the disadvantages associated with the use of solid-state detectors positioned on the patient as their periodic recalibration, and their positioning is time consuming. The method makes use of a set of correlation functions, obtained by the ratio between S t and the mid-plane dose value, D m , in standard water-equivalent phantoms, both determined along the beam central axis. The in vivo measurement of D iso required the determination of the water-equivalent thickness of the patient along the beam central axis by the treatment planning system that uses the electron densities supplied by calibrated Hounsfield numbers of the computed tomography scanner. This way it is, therefore, possible to compare D iso with the stated doses, D iso,TPS , generally used by the treatment planning system for the determination of the monitor units. The method was applied in five Italian centers that used beams of 6 MV, 10 MV, 15 MV x-rays and 60 Co γ-rays. In particular, in four centers small ion-chambers were positioned below the patient and used for the S t measurement. In only one center, the S t signals were obtained directly by the central pixels of an EPID (electronic portal imaging device) equipped with commercial software that enabled its use as a stable detector. In the four centers where an ion-chamber was positioned on the EPID, 60 pelvic treatments were followed for two fields, an anterior-posterior or a posterior-anterior irradiation and a lateral-lateral irradiation. Moreover, ten brain tumors were checked for a lateral-lateral irradiation, and five lung tumors carried out with three irradiations with different gantry angles were

  2. Application of a practical method for the isocenter point in vivo dosimetry by a transit signal

    Energy Technology Data Exchange (ETDEWEB)

    Piermattei, Angelo [UO di Fisica Sanitaria, Centro di Ricerca e Formazione ad Alta Tecnologia nelle Scienze Biomediche dell' Universita Cattolica Sacro Cuore, Campobasso (Italy); Fidanzio, Andrea [Istituto di Fisica, Universita Cattolica del Sacro Cuore, Rome (Italy); Azario, Luigi [Istituto di Fisica, Universita Cattolica del Sacro Cuore, Rome (Italy)] (and others)

    2007-08-21

    This work reports the results of the application of a practical method to determine the in vivo dose at the isocenter point, D{sub iso}, of brain thorax and pelvic treatments using a transit signal S{sub t}. The use of a stable detector for the measurement of the signal S{sub t} (obtained by the x-ray beam transmitted through the patient) reduces many of the disadvantages associated with the use of solid-state detectors positioned on the patient as their periodic recalibration, and their positioning is time consuming. The method makes use of a set of correlation functions, obtained by the ratio between S{sub t} and the mid-plane dose value, D{sub m}, in standard water-equivalent phantoms, both determined along the beam central axis. The in vivo measurement of D{sub iso} required the determination of the water-equivalent thickness of the patient along the beam central axis by the treatment planning system that uses the electron densities supplied by calibrated Hounsfield numbers of the computed tomography scanner. This way it is, therefore, possible to compare D{sub iso} with the stated doses, D{sub iso,TPS}, generally used by the treatment planning system for the determination of the monitor units. The method was applied in five Italian centers that used beams of 6 MV, 10 MV, 15 MV x-rays and {sup 60}Co {gamma}-rays. In particular, in four centers small ion-chambers were positioned below the patient and used for the S{sub t} measurement. In only one center, the S{sub t} signals were obtained directly by the central pixels of an EPID (electronic portal imaging device) equipped with commercial software that enabled its use as a stable detector. In the four centers where an ion-chamber was positioned on the EPID, 60 pelvic treatments were followed for two fields, an anterior-posterior or a posterior-anterior irradiation and a lateral-lateral irradiation. Moreover, ten brain tumors were checked for a lateral-lateral irradiation, and five lung tumors carried out with

  3. Dosimetry methods and results for the former residents of Bikini Atoll

    International Nuclear Information System (INIS)

    Greenhouse, N.A.

    1979-01-01

    The US Government utilized Bikini and Enewetak Atolls in the northern Marshall Islands of Micronesia for atomspheric tests of nuclear explosives in the 1940's and 1950's. The original inhabitants of these atolls were relocated prior to the tests. During the early 1970's, a small but growing population of Marshallese people reinhabited Bikini. Environmental and personnel radiological monitoring programs were begun in 1974 to ensure that doses and dose commitments received by Bikini residents remained within US Federal Radiation Council guidelines. Dramatic increases in 137 Cs body burdens among the inhabitants between April 1977 and 1978 may have played a significant role in the government decision to move the 140 Bikinians in residence off of the atoll in August 1978. The average 137 Cs body burden for the population was 2.3 μCi in April 1978. Several individuals, however, exceeded the maximum permissible body burden of 3 μCi, and some approached 6 μCi. The resultant total dose commitment was less than 200 mrem for the average resident. The average total dose for the mean residence interval of approx. 4.5 years was about 1 rem. The sources of exposure, the probable cause of the unexpected increase in 137 Cs body burdens, and the methods for calculating radionuclide intake and resultant doses are discussed. Suggestions are offered as to the implications of the most significant exposure pathways for the future inhabitation of Bikini and Enewetak

  4. A discussion of molecular biology methods for protein engineering

    CSIR Research Space (South Africa)

    Zawaira, A

    2011-09-01

    Full Text Available A number of molecular biology techniques are available to generate variants from a particular start gene for eventual protein expression. The authors discuss the basic principles of these methods in a repertoire that may be used to achieve...

  5. Method of 10B determination in biological specimens

    International Nuclear Information System (INIS)

    Nikitina, R.G.; Frolova, E.I.

    1981-01-01

    The paper is concerned with the methods of 10 B determination in biological specimens (blood, skin and tissues of rats). On the basis of investigations conducted there have been proposed films based on cellulose triacetate with optimal characteristics in terms of their possible utilization as solid detectors to record α-particles and recoil nuclei. The conditions of film staining are also discussed

  6. Nonlinear dimensionality reduction methods for synthetic biology biobricks' visualization.

    Science.gov (United States)

    Yang, Jiaoyun; Wang, Haipeng; Ding, Huitong; An, Ning; Alterovitz, Gil

    2017-01-19

    Visualizing data by dimensionality reduction is an important strategy in Bioinformatics, which could help to discover hidden data properties and detect data quality issues, e.g. data noise, inappropriately labeled data, etc. As crowdsourcing-based synthetic biology databases face similar data quality issues, we propose to visualize biobricks to tackle them. However, existing dimensionality reduction methods could not be directly applied on biobricks datasets. Hereby, we use normalized edit distance to enhance dimensionality reduction methods, including Isomap and Laplacian Eigenmaps. By extracting biobricks from synthetic biology database Registry of Standard Biological Parts, six combinations of various types of biobricks are tested. The visualization graphs illustrate discriminated biobricks and inappropriately labeled biobricks. Clustering algorithm K-means is adopted to quantify the reduction results. The average clustering accuracy for Isomap and Laplacian Eigenmaps are 0.857 and 0.844, respectively. Besides, Laplacian Eigenmaps is 5 times faster than Isomap, and its visualization graph is more concentrated to discriminate biobricks. By combining normalized edit distance with Isomap and Laplacian Eigenmaps, synthetic biology biobircks are successfully visualized in two dimensional space. Various types of biobricks could be discriminated and inappropriately labeled biobricks could be determined, which could help to assess crowdsourcing-based synthetic biology databases' quality, and make biobricks selection.

  7. A CT-assisted method of dosimetry in brachytherapy of lung cancer

    International Nuclear Information System (INIS)

    Senan, S.; Lagerwaard, F.J.; Pan, C. de; Sipkema, D.; Murrer, L.H.P.; Burgers, S.A.

    2000-01-01

    The toxicity of endobronchial brachytherapy (EB), in particular fatal haemoptysis and bronchial wall necrosis, has been correlated with the total dose, fraction size, volume encompassed by the 100% isodose, and a proximal tumor location. We describe a CT-based planning method which, by improving target volume definition and volumeric dose information, can improve the therapeutic ratio of EB. Sixteen CT-assisted EB procedures were performed in patients who were treated with palliative high-dose rate EB. The CT data were used to analyze applicator position in relation to anatomy. An example of a three-dimensional optimized treatment plan was generated and analyzed using different types of dose-volume histograms. The procedure was well tolerated by patients and no post-procedure complications were observed. The bronchial applicator was eccentrically positioned at the level of the carina/mainstem bronchus in 12 (of 14) CT scans. A planning CT prior to EB was not found to be useful as the final target volume and/or the final applicator position were not reliably predicted before the therapeutic bronchoscopy. CT-scans performed with the applicator in situ allowed the bronchial segments in the target volume to be identified and enabled dose prescription to the bronchial mucosa. CT-assisted EB is feasible and underlines the need for using centered applicators for proximally located tumors. By enabling accurate mucosal dose prescription, CT-assisted EB may reduce the toxicity of fractionated EB in the curative setting. However, faster on-line EB treatment planning is needed for the routine clinical application of this technique. (author)

  8. A new correction method serving to eliminate the parabola effect of flatbed scanners used in radiochromic film dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Poppinga, D., E-mail: daniela.poppinga@uni-oldenburg.de; Schoenfeld, A. A.; Poppe, B. [Medical Radiation Physics, Carl v. Ossietzky University, Oldenburg 26127, Germany and Department for Radiation Oncology, Pius Hospital, Oldenburg 26121 (Germany); Doerner, K. J. [Radiotherapy Department, General Hospital, Celle 29223 (Germany); Blanck, O. [CyberKnife Center Northern Germany, Güstrow 18273, Germany and Department for Radiation Oncology, University Clinic Schleswig-Holstein, Lübeck 23562 (Germany); Harder, D. [Medical Physics and Biophysics, Georg-August-University, Göttingen 37073 (Germany)

    2014-02-15

    Purpose: The purpose of this study is the correction of the lateral scanner artifact, i.e., the effect that, on a large homogeneously exposed EBT3 film, a flatbed scanner measures different optical densities at different positions along thex axis, the axis parallel to the elongated light source. At constant dose, the measured optical densitiy profiles along this axis have a parabolic shape with significant dose dependent curvature. Therefore, the effect is shortly called the parabola effect. The objective of the algorithm developed in this study is to correct for the parabola effect. Any optical density measured at given position x is transformed into the equivalent optical density c at the apex of the parabola and then converted into the corresponding dose via the calibration of c versus dose. Methods: For the present study EBT3 films and an Epson 10000XL scanner including transparency unit were used for the analysis of the parabola effect. The films were irradiated with 6 MV photons from an Elekta Synergy accelerator in a RW3 slab phantom. In order to quantify the effect, ten film pieces with doses graded from 0 to 20.9 Gy were sequentially scanned at eight positions along thex axis and at six positions along the z axis (the movement direction of the light source) both for the portrait and landscape film orientations. In order to test the effectiveness of the new correction algorithm, the dose profiles of an open square field and an IMRT plan were measured by EBT3 films and compared with ionization chamber and ionization chamber array measurement. Results: The parabola effect has been numerically studied over the whole measuring field of the Epson 10000XL scanner for doses up to 20.9 Gy and for both film orientations. The presented algorithm transforms any optical density at positionx into the equivalent optical density that would be measured at the same dose at the apex of the parabola. This correction method has been validated up to doses of 5.2 Gy all over the

  9. A new correction method serving to eliminate the parabola effect of flatbed scanners used in radiochromic film dosimetry

    International Nuclear Information System (INIS)

    Poppinga, D.; Schoenfeld, A. A.; Poppe, B.; Doerner, K. J.; Blanck, O.; Harder, D.

    2014-01-01

    Purpose: The purpose of this study is the correction of the lateral scanner artifact, i.e., the effect that, on a large homogeneously exposed EBT3 film, a flatbed scanner measures different optical densities at different positions along thex axis, the axis parallel to the elongated light source. At constant dose, the measured optical densitiy profiles along this axis have a parabolic shape with significant dose dependent curvature. Therefore, the effect is shortly called the parabola effect. The objective of the algorithm developed in this study is to correct for the parabola effect. Any optical density measured at given position x is transformed into the equivalent optical density c at the apex of the parabola and then converted into the corresponding dose via the calibration of c versus dose. Methods: For the present study EBT3 films and an Epson 10000XL scanner including transparency unit were used for the analysis of the parabola effect. The films were irradiated with 6 MV photons from an Elekta Synergy accelerator in a RW3 slab phantom. In order to quantify the effect, ten film pieces with doses graded from 0 to 20.9 Gy were sequentially scanned at eight positions along thex axis and at six positions along the z axis (the movement direction of the light source) both for the portrait and landscape film orientations. In order to test the effectiveness of the new correction algorithm, the dose profiles of an open square field and an IMRT plan were measured by EBT3 films and compared with ionization chamber and ionization chamber array measurement. Results: The parabola effect has been numerically studied over the whole measuring field of the Epson 10000XL scanner for doses up to 20.9 Gy and for both film orientations. The presented algorithm transforms any optical density at positionx into the equivalent optical density that would be measured at the same dose at the apex of the parabola. This correction method has been validated up to doses of 5.2 Gy all over the

  10. Biological methods used to assess surface water quality

    Directory of Open Access Journals (Sweden)

    Szczerbiñska Natalia

    2015-12-01

    Full Text Available In accordance with the guidelines of the Water Framework Directive 2000/60 (WFD, both ecological and chemical statuses determine the assessment of surface waters. The profile of ecological status is based on the analysis of various biological components, and physicochemical and hydromorphological indicators complement this assessment. The aim of this article is to present the biological methods used in the assessment of water status with a special focus on bioassay, as well as to provide a review of methods of monitoring water status. Biological test methods include both biomonitoring and bioanalytics. Water biomonitoring is used to assess and forecast the status of water. These studies aim to collect data on water pollution and forecast its impact. Biomonitoring uses organisms which are characterized by particular vulnerability to contaminants. Bioindicator organisms are algae, fungi, bacteria, larval invertebrates, cyanobacteria, macroinvertebrates, and fish. Bioanalytics is based on the receptors of contaminants that can be biologically active substances. In bioanalytics, biosensors such as viruses, bacteria, antibodies, enzymes, and biotests are used to assess degrees of pollution.

  11. Irradiation of four pencils fuel element clusters in the periphery of OSIRIS. Qualification of the calculation method by dosimetry

    International Nuclear Information System (INIS)

    Alberman, A.; Morin, C.

    1983-09-01

    The programs of qualification of PWR fuels required many irradiations in research reactors. In the periphery of the OSIRIS reactor (70 MW), two devices (IRENE and ISABELLE loops) recreating the environment of the fuel rods in power reactors have been put into service. In each device a fuel element cluster including four pencils was irradiated. The problem set by dosimetry was to calculate the enrichments of the pencils to obtain the required power level and to compensate the neutron flux gradient (in front of/behind) to obtain the same power on each one of the four pencils. The required accuracy is about 5%. Fuels dosimetry achieved on loops mockups in the ISIS reactor allowed to test the validity of the calculations and to calibrate the probes according to the nuclear power [fr

  12. A fiber-dosimetry method based on OSL from Al2O3:C for radiotherapy applications

    International Nuclear Information System (INIS)

    Gaza, R.; McKeever, S.W.S.; Akselrod, M.S.; Akselrod, A.; Underwood, T.; Yoder, C.; Andersen, C.E.; Aznar, M.C.; Marckmann, C.J.; Boetter-Jensen, L.

    2004-01-01

    We describe a high-sensitivity, fiber-optic dosimetry system based on optically stimulated luminescence (OSL) and radioluminescence from Al 2 O 3 :C single-crystal fibers (detectors). The detectors are coupled to a fiber optic delivery system and OSL from the detector is stimulated via the optical fiber cable using light from a Nd:YAG laser. The OSL is guided back along the same fiber and is detected by a photomultiplier tube. The Al 2 O 3 :C detectors are small and demonstrate high sensitivity with a large signal-to-noise ratio. We describe two modes of operation of the system and discuss algorithms that provide accurate estimation of dose rate and integrated dose in near real time. The system is free from magnetic and electrical interference, and is designed for use in several forms of radiotherapy, including in vitro brachytherapy source calibration, and in vivo dosimetry during patient treatment

  13. Calorimetric dosimetry of reactor radiation

    International Nuclear Information System (INIS)

    Radak, B.; Markovic, V.; Draganic, I.

    1961-01-01

    Calorimetric dosimetry of reactor radiation is relatively new reactor dosimetry method and the number of relevant papers is rather small. Some difficulties in applying standard methods (chemical dosemeters, ionization chambers) exist because of the complexity of radiation. In general application of calorimetric dosemeters for measuring absorbed doses is most precise. In addition to adequate choice of calorimetric bodies there is a possibility of determining the yields of each component of the radiation mixture in the total absorbed dose. This paper contains a short review of the basic calorimetry methods and some results of measurements at the RA reactor in Vinca performed by isothermal calorimeter [sr

  14. Thermoluminescent measurement in space radiation dosimetry

    International Nuclear Information System (INIS)

    Chen Mei; Qi Zhangnian; Li Xianggao; Huang Zengxin; Jia Xianghong; Wang Genliang

    1999-01-01

    The author introduced the space radiation environment and the application of thermoluminescent measurement in space radiation dosimetry. Space ionization radiation is charged particles radiation. Space radiation dosimetry was developed for protecting astronauts against space radiation. Thermoluminescent measurement is an excellent method used in the spaceship cabin. Also the authors mentioned the recent works here

  15. Mixed field dosimetry with paired ionization chambers

    International Nuclear Information System (INIS)

    Coppola, M.; Porro, F.

    1977-01-01

    This report describes the results of neutron and gamma mixed-field dosimetry obtained by the Ispra Group in the framework of the European Neutron Dosimetry intercomparison Project (ENDIP). The experimental method and the formulation employed for the derivation of Kerma results are also present

  16. Cytometric approaches to biological dosimetry

    International Nuclear Information System (INIS)

    Burger, G.

    1983-01-01

    Automatic cytometric techniques for detecting chromosomal aberrations are being tested but will not be used in routine examinations for some time to come. Automatic micronuclei counts are more promising but not sufficiently sensitive in the low dose range ( [de

  17. A new correction method serving to eliminate the parabola effect of flatbed scanners used in radiochromic film dosimetry.

    Science.gov (United States)

    Poppinga, D; Schoenfeld, A A; Doerner, K J; Blanck, O; Harder, D; Poppe, B

    2014-02-01

    The purpose of this study is the correction of the lateral scanner artifact, i.e., the effect that, on a large homogeneously exposed EBT3 film, a flatbed scanner measures different optical densities at different positions along the x axis, the axis parallel to the elongated light source. At constant dose, the measured optical density profiles along this axis have a parabolic shape with significant dose dependent curvature. Therefore, the effect is shortly called the parabola effect. The objective of the algorithm developed in this study is to correct for the parabola effect. Any optical density measured at given position x is transformed into the equivalent optical density c at the apex of the parabola and then converted into the corresponding dose via the calibration of c versus dose. For the present study EBT3 films and an Epson 10000XL scanner including transparency unit were used for the analysis of the parabola effect. The films were irradiated with 6 MV photons from an Elekta Synergy accelerator in a RW3 slab phantom. In order to quantify the effect, ten film pieces with doses graded from 0 to 20.9 Gy were sequentially scanned at eight positions along the x axis and at six positions along the z axis (the movement direction of the light source) both for the portrait and landscape film orientations. In order to test the effectiveness of the new correction algorithm, the dose profiles of an open square field and an IMRT plan were measured by EBT3 films and compared with ionization chamber and ionization chamber array measurement. The parabola effect has been numerically studied over the whole measuring field of the Epson 10000XL scanner for doses up to 20.9 Gy and for both film orientations. The presented algorithm transforms any optical density at position x into the equivalent optical density that would be measured at the same dose at the apex of the parabola. This correction method has been validated up to doses of 5.2 Gy all over the scanner bed with 2D dose

  18. Radiation dosimetry

    International Nuclear Information System (INIS)

    Harper, M.W.; Thomas, B.; Conway, J.

    1977-01-01

    A dosemeter is described that is based on the TSCD principle (thermally stimulated current dosimetry). Basically this involves irradiating a responsive material and then heating it,whereby an electric current is produced. If the material is heated in an electric field the peak value of the thermally stimulated current or alternatively the total charge released by heating, can be related to the radiation dose received. The instrument described utilises a sheet coated with a thermoplastic polymer, such as a poly4-methylpent-l-ene. The polymer should have a softening point not lower than 150 0 C with an electrical resistivity of at least 10 16 chms/cm at 150 0 C. The polymer may also be PTFE. Heating should be in the range 150 0 C to 200 0 C and the electric field in the range 50 to 10,000V/mm. (U.K.)

  19. Optothermal methods in dosimetry

    International Nuclear Information System (INIS)

    Benes, J.; Benes, R.

    1991-01-01

    Basic information is presented on the dosimetric applicability of optothermal effects induced in solids by ionizing radiation. Attention is paid to calorimetric measurements where quantities characterizing the radiant energy transmitted to the substance can be determined and the depth profiles of absorption of ionizing radiation energy in it can be measured. Another feasible application is the evaluation of powder-type thermoluminescent dosemeters by optoacoustic spectroscopy. (Z.M.). 4 figs., 17 refs

  20. Organ dosimetry

    International Nuclear Information System (INIS)

    Kaul, Dean C.; Egbert, Stephen D.; Otis, Mark D.; Kuhn, Thomas; Kerr, George D.; Eckerman, Keith F.; Cristy, Mark; Ryman, Jeffrey C.; Tang, Jabo S.; Maruyama, Takashi

    1987-01-01

    This chapter describes the technical approach, complicating factors, and sensitivities and uncertainties of calculations of doses to the organs of the A-bomb survivors. It is the object of the effort so described to provide data that enables the dosimetry system to determine the fluence, kerma, absorbed dose, and similar quantities in 14 organs and the fetus, specified as being of radiobiological interest. This object was accomplished through the use of adjoint Monte Carlo computations, which use a number of random particle histories to determine the relationship of incident neutrons and gamma rays to those transported to a target organ. The system uses these histories to correlate externally-incident energy- and angle-differential fluences with the fluence spectrum (energy differential only) within the target organ. In order for the system to work in the most efficient manner possible, two levels of data were provided. The first level, represented by approximately 6,000 random adjoint-particle histories, enables the computation of the fluence spectrum with sufficient precision to provide statistically reliable (± 6 %) mean doses within any given organ. With this limited history inventory, the system can be run rapidly for all survivors. Mean organ dose and dose uncertainty are obtainable in this mode. The second mode of operation enables the system to produce a good approximation to fluence spectrum within any organ or to produce the dose in each of an array of organ subvolumes. To be statistically reliable, this level of detail requires far more random histories, approximately 40,000 per organ. Thus, operation of the dosimetry system in this mode (i.e., with this data set) is intended to be on an as-needed, organ-specific basis, since the system run time is eight times that in the mean dose mode. (author)

  1. Tritium dosimetry and standardization

    International Nuclear Information System (INIS)

    Balonov, M.I.

    1983-01-01

    Actual problem of radiation hygiene such as an evaluation of human irradiation hazard due to a contact with tritium compounds both in industrial and public spheres is under discussion. Sources of tritium release to environment are characterized. Methods of tritium radiation monitoring are discussed. Methods of dosimetry of internal human exposure resulted from tritium compounds are developed on the base of modern representations on metbolism and tritium radiobiological effect. A system of standardization of permissible intake of tritium compounds for personnel and persons of population is grounded. Some protection measures are proposed as applied to tritium overdosage

  2. Research and innovation in radiation dosimetry

    International Nuclear Information System (INIS)

    Delgado, A.

    1999-01-01

    In this article some relevant lines of research in radiation dosimetry are presented. In some of them innovative approaches have been recently proposed in recent years. In others innovation is still to come as it is necessary in view of the insufficiency of the actual methods and techniques. mention is made to Thermoluminescence Dosimetry an to the improvement produced by new computational methods for the analysis of the usually complex TL signals. A solid state dosimetric technique recently proposed, Optically Stimulated Luminescence, OSL, is briefly presented. This technique promises advantages over TLD for personal and environmental dosimetry. The necessity of improving the measurement characteristics of neutron personal dosemeters is commented, making reference to some very recent developments. The situation of the dosimetry in connection with radiobiology research is overviewed, commenting the controversy on the adequacy and utility of the quality absorbed dose for these activities. Finally the special problematic of internal dosimetry is discussed. (Author) 25 refs

  3. ACTIVE AND PARTICIPATORY METHODS IN BIOLOGY: PROBLEM-SOLVING

    Directory of Open Access Journals (Sweden)

    Adela NEMEŞ

    2010-01-01

    Full Text Available We face with considerable challenge of developing students’ problem solving skills in our difficult environment. Good problem solving skills empower managers in their professional and personal lives. Problem solving skills are valued by academics and employers. The informations in Biology are often presented in abstract forms without contextualisation. Creative problem-solving process involves a few steps, which together provide a structured procedure for identifying challenges, generating ideas and implementing innovative solutions: identifying the problem, searching for possible solutions, selecting the most optimal solution and implementing a possible solution. Each aspect of personality has a different orientation to problem solving, different criteria for judging the effectiveness of the process and different associated strengths. Using real-world data in sample problems will also help facilitate the transfer process, since students can more easily identify with the context of a given situation. The paper describes the use of the Problem-Solving in Biology and the method of its administration. It also presents the results of a study undertaken to evaluate the value in teaching Biology. Problem-solving is seen as an essential skill that is developed in biology education.

  4. Method and apparatus to image biological interactions in plants

    Science.gov (United States)

    Weisenberger, Andrew; Bonito, Gregory M.; Reid, Chantal D.; Smith, Mark Frederick

    2015-12-22

    A method to dynamically image the actual translocation of molecular compounds of interest in a plant root, root system, and rhizosphere without disturbing the root or the soil. The technique makes use of radioactive isotopes as tracers to label molecules of interest and to image their distribution in the plant and/or soil. The method allows for the study and imaging of various biological and biochemical interactions in the rhizosphere of a plant, including, but not limited to, mycorrhizal associations in such regions.

  5. Dose estimation by biological methods; Estimacion de dosis por metodos biologicos

    Energy Technology Data Exchange (ETDEWEB)

    Guerrero C, C; David C, L; Serment G, J; Brena V, M [Instituto Nacional de Investigaciones Nucleares, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    1997-07-01

    The human being is exposed to strong artificial radiation sources, mainly of two forms: the first is referred to the occupationally exposed personnel (POE) and the second, to the persons that require radiological treatment. A third form less common is by accidents. In all these conditions it is very important to estimate the absorbed dose. The classical biological dosimetry is based in the dicentric analysis. The present work is part of researches to the process to validate the In situ Fluorescent hybridation (FISH) technique which allows to analyse the aberrations on the chromosomes. (Author)

  6. Personnel neutron dosimetry

    International Nuclear Information System (INIS)

    Hankins, D.

    1982-04-01

    This edited transcript of a presentation on personnel neutron discusses the accuracy of present dosimetry practices, requirements, calibration, dosemeter types, quality factors, operational problems, and dosimetry for a criticality accident. 32 figs

  7. Methods of 15N tracer research in biological systems

    International Nuclear Information System (INIS)

    Hirschberg, K.; Faust, H.

    1985-01-01

    The application of the stable isotope 15 N is of increasing importance in different scientific disciplines, especially in medicine, agriculture, and the biosciences. The close correlation between the growing interest and improvements of analytical procedures resulted in remarkable advances in the 15 N tracer technique. On the basis of the latest results of 15 N tracer research in life sciences and agriculture methods of 15 N tracer research in biological systems are compiled. The 15 N methodology is considered under three headings: Chemical analysis with a description of methods of sample preparation (including different separation and isolation methods for N-containing substances of biological and agricultural origin) and special procedures converting ammonia to molecular nitrogen. Isotopic analysis with a review on the most important methods of isotopic analysis of nitrogen: mass spectrometry (including the GC-MS technique), emission spectrometry, NMR spectroscopy, and other analytical procedures. 15 N-tracer techniques with a consideration of the role of the isotope dilution analysis as well as different labelling techniques and the mathematical interpretation of tracer data (modelling, N turnover experiments). In these chapters also sources of errors in chemical and isotopic analysis, the accuracy of the different methods and its importance on tracer experiments are discussed. Procedures for micro scale 15 N analysis and aspects of 15 N analysis on the level of natural abundance are considered. Furthermore some remarks on isotope effects in 15 N tracer experiments are made. (author)

  8. Progeny Clustering: A Method to Identify Biological Phenotypes

    Science.gov (United States)

    Hu, Chenyue W.; Kornblau, Steven M.; Slater, John H.; Qutub, Amina A.

    2015-01-01

    Estimating the optimal number of clusters is a major challenge in applying cluster analysis to any type of dataset, especially to biomedical datasets, which are high-dimensional and complex. Here, we introduce an improved method, Progeny Clustering, which is stability-based and exceptionally efficient in computing, to find the ideal number of clusters. The algorithm employs a novel Progeny Sampling method to reconstruct cluster identity, a co-occurrence probability matrix to assess the clustering stability, and a set of reference datasets to overcome inherent biases in the algorithm and data space. Our method was shown successful and robust when applied to two synthetic datasets (datasets of two-dimensions and ten-dimensions containing eight dimensions of pure noise), two standard biological datasets (the Iris dataset and Rat CNS dataset) and two biological datasets (a cell phenotype dataset and an acute myeloid leukemia (AML) reverse phase protein array (RPPA) dataset). Progeny Clustering outperformed some popular clustering evaluation methods in the ten-dimensional synthetic dataset as well as in the cell phenotype dataset, and it was the only method that successfully discovered clinically meaningful patient groupings in the AML RPPA dataset. PMID:26267476

  9. Complete Biological Evaluation of Therapeutical Radiopharmaceuticals in Rodents, Laboratory Beagles and Veterinary Patients - Preclinical Distribution-, Kinetic-, Excretion-, Internal Dosimetry-, Radiotoxicological-, Radiation Safety- and Efficacy Data

    International Nuclear Information System (INIS)

    Balogh, L.; Domokos, M.; Polyak, A.; Thuroczy, J.; Janoki, G.

    2009-01-01

    The research and development of various novel therapeutical radiopharmaceuticals is a huge demand in many laboratories world-wide. Beside of multiple bone metastases pain-palliation and radiosynovectomy agents a number of specific radiopharmaceutical applicants mainly for oncological applications are in the pipeline. Numerous in vitro methods are available in the first line to test the radiolabelling efficiency, the possible radioactive and non-labelled impurities, the stability of the label at different conditions and mediums, and some specific characteristics of radiopharmaceutical applicants eg.: receptor binding assays, antigen-antibody assays. But, still before human clinical trials there are several questions to be solved in regards of toxicology, radiotoxicology, radiation safety and maybe most importantly the efficacy tasks. All these issues cannot be answered without animal tests. Several decades back animal tests in radiopharmacy meant only standard bioassays in a large number of healthy rodents. Later on pathological models eg.: human tumor xenografts in immunodeficient animals came-out and through them radiopharmaceutical tumor-uptake by the targets were available to evaluate in vivo as well. Xenografts are still popular and widely used models in the field but instead of wide-scaled bioassays nowadays repeated scintiscans or hybrid images (SPECT/CT, PET/CT) are more and more often used to answer kinetic-, excretion-, tumor uptake, internal dosimetry (Minimum Effective Dose, Maximum Tolerable Dose, critical organ doses, tumor doses) questions. Greater animals like laboratory Beagles are more closely in size, clinical and metabolic parameters to the human objects so playing a more perfect role of human medical doctor and especially veterinary patients. Easy to understand that many of the spontaneously occurring companion animal diseases are a good model of human pathological diseases. The need of a better diagnosis and treatment of that animals meets with

  10. Treatment of laundry wastewater by biological and electrocoagulation methods.

    Science.gov (United States)

    Ramcharan, Terelle; Bissessur, Ajay

    2017-01-01

    The present study describes an improvement in the current electrocoagulation treatment process and focuses on a comparative study for the clean-up of laundry wastewater (LWW) after each wash and rinse cycle by biological and electrocoagulation treatment methods. For biological treatment, the wastewater was treated with a Bacillus strain of aerobic bacteria especially suited for the degradation of fats, lipids, protein, detergents and hydrocarbons. Treatment of the LWW by electrocoagulation involved the oxidation of aluminium metal upon the application of a controlled voltage which produces various aluminium hydroxy species capable of adsorbing pollutants from the wastewater. The efficiency of the clean-up of LWW using each method was assessed by determination of surfactant concentration, chemical oxygen demand and total dissolved solids. A rapid decrease in surfactant concentration was noted within 0.5 hour of electrocoagulation, whereas a notable decrease in the surfactant concentration was observed only after 12 hour of biological treatment. The rapid generation of aluminium hydroxy species in the electrocoagulation cell allowed adsorption of pollutants at a faster rate when compared to the aerobic degradation of the surfactant; hence a reduced period of time is required for treatment of LWW by electrocoagulation.

  11. Dosimetry for radiation processing

    DEFF Research Database (Denmark)

    Miller, Arne

    1986-01-01

    During the past few years significant advances have taken place in the different areas of dosimetry for radiation processing, mainly stimulated by the increased interest in radiation for food preservation, plastic processing and sterilization of medical products. Reference services both...... and sterilization dosimetry, optichromic dosimeters in the shape of small tubes for food processing, and ESR spectroscopy of alanine for reference dosimetry. In this paper the special features of radiation processing dosimetry are discussed, several commonly used dosimeters are reviewed, and factors leading...

  12. Biclustering methods: biological relevance and application in gene expression analysis.

    Directory of Open Access Journals (Sweden)

    Ali Oghabian

    Full Text Available DNA microarray technologies are used extensively to profile the expression levels of thousands of genes under various conditions, yielding extremely large data-matrices. Thus, analyzing this information and extracting biologically relevant knowledge becomes a considerable challenge. A classical approach for tackling this challenge is to use clustering (also known as one-way clustering methods where genes (or respectively samples are grouped together based on the similarity of their expression profiles across the set of all samples (or respectively genes. An alternative approach is to develop biclustering methods to identify local patterns in the data. These methods extract subgroups of genes that are co-expressed across only a subset of samples and may feature important biological or medical implications. In this study we evaluate 13 biclustering and 2 clustering (k-means and hierarchical methods. We use several approaches to compare their performance on two real gene expression data sets. For this purpose we apply four evaluation measures in our analysis: (1 we examine how well the considered (biclustering methods differentiate various sample types; (2 we evaluate how well the groups of genes discovered by the (biclustering methods are annotated with similar Gene Ontology categories; (3 we evaluate the capability of the methods to differentiate genes that are known to be specific to the particular sample types we study and (4 we compare the running time of the algorithms. In the end, we conclude that as long as the samples are well defined and annotated, the contamination of the samples is limited, and the samples are well replicated, biclustering methods such as Plaid and SAMBA are useful for discovering relevant subsets of genes and samples.

  13. Introduction to the special issue of Radiation Protection Dosimetry

    International Nuclear Information System (INIS)

    Anon.

    2016-01-01

    This special issue is a collection of peer-reviewed articles derived from presentations at the fourth EPR BioDose Meeting, held in Hanover, NH, USA in 4-8 October 2015. Organised by The International Association of Biological and EPR Radiation Dosimetry (IABERD), this meeting was held in combination with two international conferences (The International Symposium on EPR Dosimetry and Dating and The International Conference on Biodosimetry) and a symposium (The International EPR Society). The primary focus of this conference was on medical response to events in which large numbers of individuals may be exposed to significant levels of ionising radiation; topics included biodosimetry techniques, radiation mitigators, model systems to develop countermeasures, new data from different exposure events and the implication of these methods in a radiological emergency or in terrorist attack scenarios. (authors)

  14. Application of the selected physical methods in biological research

    Directory of Open Access Journals (Sweden)

    Jaromír Tlačbaba

    2013-01-01

    Full Text Available This paper deals with the application of acoustic emission (AE, which is a part of the non-destructive methods, currently having an extensive application. This method is used for measuring the internal defects of materials. AE has a high potential in further research and development to extend the application of this method even in the field of process engineering. For that matter, it is the most elaborate acoustic emission monitoring in laboratory conditions with regard to external stimuli. The aim of the project is to apply the acoustic emission recording the activity of bees in different seasons. The mission is to apply a new perspective on the behavior of colonies by means of acoustic emission, which collects a sound propagation in the material. Vibration is one of the integral part of communication in the community. Sensing colonies with the support of this method is used for understanding of colonies biological behavior to stimuli clutches, colony development etc. Simulating conditions supported by acoustic emission monitoring system the illustrate colonies activity. Collected information will be used to represent a comprehensive view of the life cycle and behavior of honey bees (Apis mellifera. Use of information about the activities of bees gives a comprehensive perspective on using of acoustic emission in the field of biological research.

  15. External audit in radiotherapy dosimetry

    International Nuclear Information System (INIS)

    Thwaites, D.I.; Western General Hospital, Edinburgh

    1996-01-01

    Quality audit forms an essential part of any comprehensive quality assurance programme. This is true in radiotherapy generally and in specific areas such as radiotherapy dosimetry. Quality audit can independently test the effectiveness of the quality system and in so doing can identify problem areas and minimize their possible consequences. Some general points concerning quality audit applied to radiotherapy are followed by specific discussion of its practical role in radiotherapy dosimetry, following its evolution from dosimetric intercomparison exercises to routine measurement-based on-going audit in the various developing audit networks both in the UK and internationally. Specific examples of methods and results are given from some of these, including the Scottish+ audit group. Quality audit in radiotherapy dosimetry is now well proven and participation by individual centres is strongly recommended. Similar audit approaches are to be encouraged in other areas of the radiotherapy process. (author)

  16. Progetto EURAMET: HLT03 DUTy - Dosimetria per terapie ultrasonore. Confronto tra metodi di misura - EURAMET: HLT03 DUTy - Dosimetry for ultrasound therapy. Intercomparison of methods

    Directory of Open Access Journals (Sweden)

    Giovanni Durando

    2016-03-01

    Full Text Available La mancanza di una definizione della dose ultrasonora rende di fatto impossibile la valutazione della più appropriata “quantità” energia ceduta ai tessuti dal fascio ultrasonoro emesso da un trasduttore durante una terapia. Il progetto di ricerca “Dosimetry for Ultrasound Therapy - DUTy”, finanziato dal programma di ricerca EURAMET EMRP, aveva tra i suoi principali obiettivi, oltre al confronto interlaboratorio che validasse le capacità metrologiche dei laboratori partecipanti, la ricerca della definizione di dose ultrasonora che consentisse la definizione di un piano terapeutico specifico per ogni paziente. ------ Standardized and traceable dose has not yet been developed for medical ultrasound applications. This means that the ‘amount’ of ultrasound required for a particular therapy cannot be calculated and that the ‘amount’ actually delivered quantified. The aim of EURAMET EMRP project “Dosimetry for Ultrasound Therapy - DUTy” project was developing the metrological infrastructure (definitions, validated measurement and modelling methods which underpins the specification of dose for therapeutic ultrasound applications allowing appropriate treatment planning and risk assessment.

  17. Assessment of neutronic parameter's uncertainties obtained within the reactor dosimetry framework: Development and application of the stochastic methods of analysis

    Energy Technology Data Exchange (ETDEWEB)

    Destouches, C.; Beretz, D. [Service de Physique Experimentale, CEA-CAD/DEN/DER/SPEx, Departement d' Etudes des Reacteurs, 13108 St-Paul lez Durance Cedex (France); Devictor, N. [Service d' Etude des Systemes Innovant, CEA-CAD/DEN/DER/SESI, Departement d' Etudes des Reacteurs, 13108 St-Paul lez Durance Cedex (France); Gregoire, G. [Service de Physique Experimentale, CEA-CAD/DEN/DER/SPEx, Departement d' Etudes des Reacteurs, 13108 St-Paul lez Durance Cedex (France)

    2006-07-01

    One of the main objectives of reactor dosimetry is the determination of the physical parameters characterizing the neutronic field in which the studied sample is irradiated. The knowledge of the associated uncertainties represents a significant stake for nuclear industry as shows the high uncertainty value of 15% (k=1) commonly allowed for the calculated neutron flux (E> 1 MeV) on the vessel and internal structures. The study presented in this paper aims at determining then reducing uncertainties associated with the reactor dosimetry interpretation process. After a brief presentation of the interpretation process, input data uncertainties identification and quantification are performed in particular with regard to covariances. Then uncertainties propagation is carried out and analyzed by deterministic and stochastic methods on a representative case. Finally, a Monte Carlo sensitivity study based on Sobol indices is achieved on a case leading to derive the most penalizing input uncertainties. This paper concludes rising improvement axes to be studied for the input data knowledge. It highlights for example the need for having realistic variance-covariance matrices associated with input data (cross sections libraries, neutron computation code's outputs, ...). Lastly, the methodology principle presented in this paper is enough general to be easily transposable for other measurements data interpretation processes. (authors)

  18. Dosimetry for photo-coagulation by the use of autofluorescence

    Science.gov (United States)

    Brodzinski, T.

    1989-01-01

    A basic problem when using lasers in medicine is that of dosimetry. The definition of the terms dose, effective value etc. will be dealt with in Chapter 2. This chapter is intended to give an insight into the problems of basic dosimetry and its technical realization within the field of photocoagulation, an established method used to treat the retina, or some skin diseases. Until now the coagulation process was assessed to be completed when the irradiated area became blanched. However in terms of dosimetry, it must be possible to predict or at least to monitor the biological effect using well-defined parameters for the laser or in achieving an objective measure for a feedback loop. In the case of coagulation, a prediction in this form is not possible. There are two ways of pro- ceeding further see Fig. 1. One can either determine the physical effect, i.e. temperature, by some kind of sensors, or even better, use some biological effect as a direct measure of the effective dose applied.

  19. A preliminary study on thermoluminescence of AMOLED glass from mobile phones for retrospective dosimetry

    International Nuclear Information System (INIS)

    Kim, Hyoungtaek; Lee, Jungil; Chang, Insu; Lee, Seung Kyu; Kim, Min Chae; Park, Sang Won; Kim, Jang-Lyul; Kim, Bong-Hwan; Yu, Hyungjoon; Kim, Ah-reum

    2017-01-01

    Since mobile phones are always carried by individuals, the retrospective dosimetry using thermoluminescence (TL) and optically stimulated luminescence (OSL) characteristics of elements in mobile phone is intensively developing nowadays due to its advantages over conventional biological dosimetry techniques. Using a TL and OSL method on resistors and inductors in a mobile phone, a low background dose (zero dose) about tens of mGy is acquired in previous study. Radiation workers have to wear a dosimeter to assess individual exposure during their works. This monitoring system facilitate a fast medical treatment for highly exposed workers in case of a radiation accident. In the event of large-scale radiation accidents, where most of the subjects are ordinary people, it is difficult to evaluate the individual dose due to the absence of dosimeters. A technique for dose evaluation using a radiation dependency of various materials in the absence of a dosimeter is called retrospective dosimetry.

  20. Contribution of new cytogenetic techniques in the estimations of old irradiations in retrospective biological dosimetry; Apport des nouvelles techniques de cytogenetiques dans l'estimation des irradiations anciennes en dosimetrie biologique retrospective

    Energy Technology Data Exchange (ETDEWEB)

    Pouzoulet, F

    2007-10-15

    The objective of this study was to answer three questions: if the translocations are steady: the results have shown that the translocations even if they are not obligatory steady can be used in retrospective dosimetry. Furthermore, it appeared important to consider the complex translocations in view of their relative stability and complementary information they bring ( quality of radiation, received dose). The second question is what contribution of the M-F.I.S.H. in the translocations analysis in comparison with the F.I.S.H.-3: we have shown that the M-F.I.S.H. would allow to raise the whole of doubt due to a partial genome observation. that has for effect to increase the precision of the analysis and that what ever be the received dose. The third question is if there are differences between the chromosomal aberrations generated by x radiation of 50 keV and by gamma radiation from cobalt-60: yes, the low energy photons generate more translocations than the photons coming from cobalt-60. But they generate less dicentrics. this difference comes from the way the energy is deposited that leads to a more important formation of complex and multiple translocations with the low energy photons. this could constitute a problem in the use of low energy photons in radiotherapy. it would seem that the simple translocations rate is not influenced by the photons energy. (N.C.)

  1. Contribution of new cytogenetic techniques in the estimations of old irradiations in retrospective biological dosimetry; Apport des nouvelles techniques de cytogenetiques dans l'estimation des irradiations anciennes en dosimetrie biologique retrospective

    Energy Technology Data Exchange (ETDEWEB)

    Pouzoulet, F

    2007-10-15

    The objective of this study was to answer three questions: if the translocations are steady: the results have shown that the translocations even if they are not obligatory steady can be used in retrospective dosimetry. Furthermore, it appeared important to consider the complex translocations in view of their relative stability and complementary information they bring ( quality of radiation, received dose). The second question is what contribution of the M-F.I.S.H. in the translocations analysis in comparison with the F.I.S.H.-3: we have shown that the M-F.I.S.H. would allow to raise the whole of doubt due to a partial genome observation. that has for effect to increase the precision of the analysis and that what ever be the received dose. The third question is if there are differences between the chromosomal aberrations generated by x radiation of 50 keV and by gamma radiation from cobalt-60: yes, the low energy photons generate more translocations than the photons coming from cobalt-60. But they generate less dicentrics. this difference comes from the way the energy is deposited that leads to a more important formation of complex and multiple translocations with the low energy photons. this could constitute a problem in the use of low energy photons in radiotherapy. it would seem that the simple translocations rate is not influenced by the photons energy. (N.C.)

  2. Chemical dosimetry principles in high dose dosimetry

    International Nuclear Information System (INIS)

    Mhatre, Sachin G.V.

    2016-01-01

    In radiation processing, activities of principal concern are process validation and process control. The objective of such formalized procedures is to establish documentary evidence that the irradiation process has achieved the desired results. The key element of such activities is inevitably a well characterized reliable dosimetry system that is traceable to recognized national and international dosimetry standards. Only such dosimetry systems can help establish the required documentary evidence. In addition, industrial radiation processing such as irradiation of foodstuffs and sterilization of health careproducts are both highly regulated, in particular with regard to dose. Besides, dosimetry is necessary for scaling up processes from the research level to the industrial level. Thus, accurate dosimetry is indispensable

  3. Methods and models in mathematical biology deterministic and stochastic approaches

    CERN Document Server

    Müller, Johannes

    2015-01-01

    This book developed from classes in mathematical biology taught by the authors over several years at the Technische Universität München. The main themes are modeling principles, mathematical principles for the analysis of these models, and model-based analysis of data. The key topics of modern biomathematics are covered: ecology, epidemiology, biochemistry, regulatory networks, neuronal networks, and population genetics. A variety of mathematical methods are introduced, ranging from ordinary and partial differential equations to stochastic graph theory and  branching processes. A special emphasis is placed on the interplay between stochastic and deterministic models.

  4. A new method for dosing uranium in biological media

    International Nuclear Information System (INIS)

    Henry, Ph.; Kobisch, Ch.

    1964-01-01

    This report describes a new method for dosing uranium in biological media based on measurement of alpha activity. After treatment of the sample with a mineral acid, the uranium is reduced to the valency four by trivalent titanium and is precipitated as phosphate in acid solution. The uranium is then separated from the titanium by precipitation as UF 4 with lanthanum as carrier. A slight modification, unnecessary in the case of routine analyses, makes it possible to eliminate other possible alpha emitters (thorium and transuranic elements). (authors) [fr

  5. Biological stability of drinking water: controlling factors, methods and challenges

    Directory of Open Access Journals (Sweden)

    Emmanuelle ePrest

    2016-02-01

    Full Text Available Biological stability of drinking water refers to the concept of providing consumers with drinking water of same microbial quality at the tap as produced at the water treatment facility. However, uncontrolled growth of bacteria can occur during distribution in water mains and premise plumbing, and can lead to hygienic (e.g. development of opportunistic pathogens, aesthetic (e.g. deterioration of taste, odour, colour or operational (e.g. fouling or biocorrosion of pipes problems. Drinking water contains diverse microorganisms competing for limited available nutrients for growth. Bacterial growth and interactions are regulated by factors such as (i type and concentration of available organic and inorganic nutrients, (ii type and concentration of residual disinfectant, (iii presence of predators such as protozoa and invertebrates, (iv environmental conditions such as water temperature, and (v spatial location of microorganisms (bulk water, sediment or biofilm. Water treatment and distribution conditions in water mains and premise plumbing affect each of these factors and shape bacterial community characteristics (abundance, composition, viability in distribution systems. Improved understanding of bacterial interactions in distribution systems and of environmental conditions impact is needed for better control of bacterial communities during drinking water production and distribution. This article reviews (i existing knowledge on biological stability controlling factors and (ii how these factors are affected by drinking water production and distribution conditions. In addition, (iii the concept of biological stability is discussed in light of experience with well-established and new analytical methods, enabling high throughput analysis and in-depth characterization of bacterial communities in drinking water. We discuss how knowledge gained from novel techniques will improve design and monitoring of water treatment and distribution systems in order to

  6. Biological Stability of Drinking Water: Controlling Factors, Methods, and Challenges

    Science.gov (United States)

    Prest, Emmanuelle I.; Hammes, Frederik; van Loosdrecht, Mark C. M.; Vrouwenvelder, Johannes S.

    2016-01-01

    Biological stability of drinking water refers to the concept of providing consumers with drinking water of same microbial quality at the tap as produced at the water treatment facility. However, uncontrolled growth of bacteria can occur during distribution in water mains and premise plumbing, and can lead to hygienic (e.g., development of opportunistic pathogens), aesthetic (e.g., deterioration of taste, odor, color) or operational (e.g., fouling or biocorrosion of pipes) problems. Drinking water contains diverse microorganisms competing for limited available nutrients for growth. Bacterial growth and interactions are regulated by factors, such as (i) type and concentration of available organic and inorganic nutrients, (ii) type and concentration of residual disinfectant, (iii) presence of predators, such as protozoa and invertebrates, (iv) environmental conditions, such as water temperature, and (v) spatial location of microorganisms (bulk water, sediment, or biofilm). Water treatment and distribution conditions in water mains and premise plumbing affect each of these factors and shape bacterial community characteristics (abundance, composition, viability) in distribution systems. Improved understanding of bacterial interactions in distribution systems and of environmental conditions impact is needed for better control of bacterial communities during drinking water production and distribution. This article reviews (i) existing knowledge on biological stability controlling factors and (ii) how these factors are affected by drinking water production and distribution conditions. In addition, (iii) the concept of biological stability is discussed in light of experience with well-established and new analytical methods, enabling high throughput analysis and in-depth characterization of bacterial communities in drinking water. We discussed, how knowledge gained from novel techniques will improve design and monitoring of water treatment and distribution systems in order

  7. Biological Stability of Drinking Water: Controlling Factors, Methods, and Challenges

    KAUST Repository

    Prest, Emmanuelle I.

    2016-02-01

    Biological stability of drinking water refers to the concept of providing consumers with drinking water of same microbial quality at the tap as produced at the water treatment facility. However, uncontrolled growth of bacteria can occur during distribution in water mains and premise plumbing, and can lead to hygienic (e.g., development of opportunistic pathogens), aesthetic (e.g., deterioration of taste, odor, color) or operational (e.g., fouling or biocorrosion of pipes) problems. Drinking water contains diverse microorganisms competing for limited available nutrients for growth. Bacterial growth and interactions are regulated by factors, such as (i) type and concentration of available organic and inorganic nutrients, (ii) type and concentration of residual disinfectant, (iii) presence of predators, such as protozoa and invertebrates, (iv) environmental conditions, such as water temperature, and (v) spatial location of microorganisms (bulk water, sediment, or biofilm). Water treatment and distribution conditions in water mains and premise plumbing affect each of these factors and shape bacterial community characteristics (abundance, composition, viability) in distribution systems. Improved understanding of bacterial interactions in distribution systems and of environmental conditions impact is needed for better control of bacterial communities during drinking water production and distribution. This article reviews (i) existing knowledge on biological stability controlling factors and (ii) how these factors are affected by drinking water production and distribution conditions. In addition, (iii) the concept of biological stability is discussed in light of experience with well-established and new analytical methods, enabling high throughput analysis and in-depth characterization of bacterial communities in drinking water. We discussed, how knowledge gained from novel techniques will improve design and monitoring of water treatment and distribution systems in order

  8. Dosimetry system 1986

    International Nuclear Information System (INIS)

    Woolson, William A.; Egbert, Stephen D.; Gritzner, Michael L.

    1987-01-01

    In May 1983, the authors proposed a dosimetry system for use by the Radiation Effects Research Foundation (RERF) that would incorporate the new findings and calculations of the joint United States - Japan working groups on the reassessment of A-bomb dosimetry. The proposed dosimetry system evolved from extensive discussions with RERF personnel, numerous meetings of the scientists from Japan and the United States involved in the dosimetry reassessment research, and requirements expressed by epidemiologists and radiobiologists on the various review panels. The dosimetry system proposed was based on considerations of the dosimetry requirements for the normal work of RERF and for future research in radiobiology, the computerized input data on A-bomb survivors available in the RERF data base, the level of detail, precision, and accuracy of various components of the dosimetric estimates, and the computer resources available at RERF in Hiroshima. These discussions and our own experience indicated that, in light of the expansion of computer and radiation technologies and the desire for more detail in the dosimetry, an entirely new approach to the dosimetry system was appropriate. This resulted in a complete replacement of the T65D system as distinguished from a simpler approach involving a renormalization of T65D parameters to reflect the new dosimetry. The proposed dosimetry system for RERF and the plan for implementation was accepted by the Department of Energy (DOE) Working Group on A-bomb Dosimetry chaired by Dr. R.F. Christy. The dosimetry system plan was also presented to the binational A-bomb dosimetry review groups for critical comment and was discussed at joint US-Japan workshop. A prototype dosimetry system incorporating preliminary dosimetry estimates and applicable to only a limited set of A-bomb survivors was installed on the RERF computer system in the fall of 1984. This system was successfully operated at RERF and provided an initial look at the impact of

  9. Applications of gel dosimetry

    International Nuclear Information System (INIS)

    Ibbott, Geoffrey S

    2004-01-01

    Gel dosimetry has been examined as a clinical dosimeter since the 1950s. During the last two decades, however, a rapid increase in the number of investigators has been seen, and the body of knowledge regarding gel dosimetry has expanded considerably. Gel dosimetry is still considered a research project, and the introduction of this tool into clinical use is proceeding slowly. This paper will review the characteristics of gel dosimetry that make it desirable for clinical use, the postulated and demonstrated applications of gel dosimetry, and some complications, set-backs, and failures that have contributed to the slow introduction into routine clinical use

  10. Cytogenetic Dosimetry: Applications in Preparedness for and Response to Radiation Emergencies (Spanish Edition); Dosimetría citogenética: Aplicaciones en materia de preparación y respuesta a las emergencias radiológicas

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2014-10-15

    Cytogenetic dosimetry is recognized as a valuable dose assessment method which fills a gap in dosimetric technology, particularly when there are difficulties in interpreting the data, in cases where there is reason to believe that persons not wearing dosimeters have been exposed to radiation, in cases of claims for compensation for radiation injuries that are not supported by unequivocal dosimetric evidence, or in cases of exposure over an individual’s working lifetime. The IAEA has maintained a long standing involvement in biological dosimetry commencing in 1978. This association has been through a sequence of coordinated research programmes (CRPs), the running of regional and national training courses, the sponsorship of individual training fellowships, and the provision of equipment to laboratories in Member States, establishing capabilities in biological dosimetry. From this has arisen the provision to Member States of advice regarding the best focus for research and suggestions for the most suitable techniques for future practice in biological dosimetry. One CRP resulted in the publication in 1986 of a manual, entitled Biological Dosimetry: Chromosomal Aberration Analysis for Dose Assessment (Technical Reports Series No. 260). This was superseded in 2001 by a revised second edition, Technical Reports Series No. 405. This present publication constitutes a third edition, with extensive updating to reflect the considerable advances that have been made in cytogenetic biological dosimetry during the past decade.

  11. Biological characteristics of crucian by quantitative inspection method

    Science.gov (United States)

    Chu, Mengqi

    2015-04-01

    Biological characteristics of crucian by quantitative inspection method Through quantitative inspection method , the biological characteristics of crucian was preliminary researched. Crucian , Belongs to Cypriniformes, Cyprinidae, Carassius auratus, is a kind of main plant-eating omnivorous fish,like Gregarious, selection and ranking. Crucian are widely distributed, perennial water all over the country all have production. Determine the indicators of crucian in the experiment, to understand the growth, reproduction situation of crucian in this area . Using the measured data (such as the scale length ,scale size and wheel diameter and so on) and related functional to calculate growth of crucian in any one year.According to the egg shape, color, weight ,etc to determine its maturity, with the mean egg diameter per 20 eggs and the number of eggs per 0.5 grams, to calculate the relative and absolute fecundity of the fish .Measured crucian were female puberty. Based on the relation between the scale diameter and length and the information, linear relationship between crucian scale diameter and length: y=1.530+3.0649. From the data, the fertility and is closely relative to the increase of age. The older, the more mature gonad development. The more amount of eggs. In addition, absolute fecundity increases with the pituitary gland.Through quantitative check crucian bait food intake by the object, reveals the main food, secondary foods, and chance food of crucian ,and understand that crucian degree of be fond of of all kinds of bait organisms.Fish fertility with weight gain, it has the characteristics of species and populations, and at the same tmes influenced by the age of the individual, body length, body weight, environmental conditions (especially the nutrition conditions), and breeding habits, spawning times factors and the size of the egg. After a series of studies of crucian biological character, provide the ecological basis for local crucian's feeding, breeding

  12. Aqueous chemical dosimetry

    International Nuclear Information System (INIS)

    Matthews, R.W.

    1982-01-01

    Aqueous chemical dosimetry based on ceric and ferrous sulfate solutions and on a number of fluorescence-induced systems is reviewed. Particular attention is given to the factors affecting the response of these dosimeters to radiation and the corrections necessary for more accurate dosimetry under various irradiation conditions. The effect of cerous and ceric ion, oxygen, and sulfuric acid concentration on the ceric dosimeter is discussed together with the effects of temperature, energy of radiation, degraded energy spectra, and peroxysulfuric acids. Practical aspects of ceric/cerous dosimetry are given. Although ferrous sulfate solution is the most important and widely studied reference dosimeter, general agreement has not been reached on the ''best'' value for the molar extinction coefficient of ferric ions nor on the correction necessary to the G(Fe 3 - ) value for irradiations at temperatures significantly different from 25 0 C. New data are presented which indicate that the larger temperature coefficients given in the literature are more accurate. The ferrous sulfate system has been of great importance in establishing the primary radiolytic yields for 0.4 M sulfuric acid solution; it is shown how the failure to take into account the effect of oxygen and ferrous sulfate concentrations has led to erroneously high estimates of the zero solute concentration values in acid solutions. Some of the methods for extending the dose ranges measurable with ferrous sulfate-based solutions are reviewed. Substances which on irradiation give highly fluorescent products are among the most sensitive aqueous chemical dosimeters. These include benzoate and terephthalate solutions and the more recent coumarin and trimesate solutions. Advantages and disadvantages system are discussed. (author)

  13. Individual dosimetry of workers and patients: implementation and perspectives

    International Nuclear Information System (INIS)

    Rannou, A.; Aubert, B.; Lahaye, Th.; Scaff, P.; Casanova, Ph.; Van Bladel, L.; Queinnec, F.; Valendru, N.; Jehanno, J.; Grude, E.; Berard, Ph.; Desbree, A.; Kafrouni, H.; Paquet, F.; Vanhavere, F.; Bridier, A.; Ginestet, Ch.; Magne, S.; Donadille, L.; Bordy, J.M.; Bottollier-Depois, J.F.; Barrere, J.L.; Ferragut, A.; Metivier, H.; Gaillard-Lecanu, E.

    2008-01-01

    These days organised by the section of the technical protection of the S.F.R.P. review the different techniques of dosimetry used in France and Europe, and present the future orientations.The different interventions are as follow: Individual exposures of the workers: historic assessment and perspectives; medical exposure: where are the doses; legal obligations in individual dosimetry: which are the objective and the need on the subject; the dosimetry follow-up of workers by the S.I.S.E.R.I. system: assessment and perspectives; impact of the norm ISO 20553 on the follow-up of internal exposure; the implementation of the patient dose measurement in Belgium; techniques of passive dosimetry used in Europe; Supervision radiation protection at EDF: long term and short term approach; Comparison active and passive dosimetry at Melox; methodology for the choice of new neutron dosemeters; the working group M.E.D.O.R.: guide of internal dosimetry for the use of practitioners; O.E.D.I.P.E.: tool of modeling for the personalized internal dosimetry; the use of the Monte-Carlo method for the planning of the cancer treatment by radiotherapy becomes a reality; the works of the committee 2 of the ICRP; passive dosimetry versus operational dosimetry: situation in Europe; Implementation of the in vivo dosimetry in a radiotherapy department: experience of the Gustave Roussy institute; experience feedback on the in vivo measures in radiotherapy, based on the use of O.S.L. pellets; multi points O.S.L. instrumentation for the radiation dose monitoring in radiotherapy; dosimetry for extremities for medical applications: principle results of the European contract C.O.N.R.A.D.; references and perspectives in dosimetry; what perspectives for numerical dosimetry, an example: Sievert; system of dose management: how to answer to needs; the last technical evolutions in terms of electronic dosimetry in nuclear power plant; the fourth generation type reactors: what dosimetry. (N.C.)

  14. Method for estimating optimal spectral and energy parameters of laser irradiation in photodynamic therapy of biological tissue

    Energy Technology Data Exchange (ETDEWEB)

    Lisenko, S A; Kugeiko, M M [Belarusian State University, Minsk (Belarus)

    2015-04-30

    We have solved the problem of layer-by-layer laser-light dosimetry in biological tissues and of selecting an individual therapeutic dose in laser therapy. A method is proposed for real-time monitoring of the radiation density in tissue layers in vivo, concentrations of its endogenous (natural) and exogenous (specially administered) chromophores, as well as in-depth distributions of the spectrum of light action on these chromophores. As the background information use is made of the spectrum of diffuse light reflected from a patient's tissue, measured by a fibre-optic spectrophotometer. The measured spectrum is quantitatively analysed by the method of approximating functions for fluxes of light multiply scattered in tissue and by a semi-analytical method for calculating the in-depth distribution of the light flux in a multi-layered medium. We have shown the possibility of employing the developed method for monitoring photosensitizer and oxyhaemoglobin concentrations in tissue, light power absorbed by chromophores in tissue layers at different depths and laser-induced changes in the tissue morphology (vascular volume content and ratios of various forms of haemoglobin) during photodynamic therapy. (biophotonics)

  15. French experience in the field of internal dosimetry assessment at a nuclear workplace. Methods and results on industrial uranium dioxide

    International Nuclear Information System (INIS)

    Ansoborlo, E.; Henge-Napoli, M.H.; Rannou, A.; Pihet, P.; Dewez, P.

    1995-01-01

    The implementation of the new ICRP recommendations and the diversity of industrial exposure materials make it necessary to modify our approach of assessing internal dosimetry. This paper describes a methodology developed to asses different parameters such as activity concentration and particle size distribution at the workplace; physico-chemical characteristics of industrial dust handled; and in vitro and in vivo solubility in order to determine the absorption rate blood. The determination of such specific parameters will lead to dose calculation in terms of committed effective Dose Per Unit of Intake (DPUI). Results obtained for an industrial uranium dioxide, UO 2 , at a French nuclear facility are presented. (author). 21 refs., 2 figs., 4 tabs

  16. Separation methods for captopril in pharmaceuticals and biological fluids.

    Science.gov (United States)

    Mansour, Fotouh R; Danielson, Neil D

    2012-06-01

    Captopril (CAP) is an orally active angiotensin-converting enzyme (ACE) inhibitor and has been widely used for management of hypertension and congestive heart failure. CAP lacks an aromatic chromophore required for facile direct UV detection and also has two chiral centers. These factors can render the determination of CAP in complex matrices challenging. This review covers more than 20 years of analytical research on this drug, focusing mainly on pharmaceutical and biological applications. The primary separation techniques discussed are gas chromatography, liquid chromatography, and capillary electrophoresis. The structures of the CAP derivatizing agents as well as a table summarizing various HPLC methods are provided. A discussion of key recent chromatographic and electrophoretic methods for other ACE inhibitors is also present. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Remediation of Soil Contaminated with Uranium using a Biological Method

    International Nuclear Information System (INIS)

    Park, Hye Min; Kim, Gye Nam; Shon, Dong Bin; Lee, Ki Won; Chung, Un Soo; Moon, Jai Kwon

    2011-01-01

    Bioremediation is a method to cleanup contaminants in soil or ground water with microorganisms. The biological method can reduce the volume of waste solution and the construction cost and operation cost of soil remediation equipment. Bioremediation can be divided into natural attenuation, bioaugmentation, biostimulation. Biostimulation is technology to improve natural purification by adding nutritional substances, supplying oxygen and controlling pH. In this study, penatron, that is a nutritional substances, was mixed with soil. Optimum conditions for mixing ratios of penatron and soil, and the pH of soil was determined through several bioremediation experiments with soil contaminated with uranium. Also, under optimum experiment conditions, the removal efficiencies of soil and concrete according to reaction time were measured for feasibility analysis of soil and concrete bioremediations

  18. NF ISO 7097-1. Nuclear fuel technology - Uranium dosimetry in solutions, in uranium hexafluoride and in solids - Part 1: reduction with iron (II) / oxidation with potassium bi-chromate / titration method

    International Nuclear Information System (INIS)

    2002-04-01

    This standard document describes the mode of operation of three different methods for the quantitative dosimetry of uranium in solutions, in UF 6 and in solids: reduction by iron (II), oxidation by potassium bi-chromate and titration. (J.S.)

  19. Clinical dosimetry using mosfets

    International Nuclear Information System (INIS)

    Ramani, Ramaseshan; Russell, Stephen; O'Brien, Peter

    1997-01-01

    Purpose: The use of metal oxide-silicon field effect transistors (MOSFETs) as clinical dosimeters is demonstrated for a number of patients with targets at different clinical sites. Methods and Materials: Commercially available MOSFETs were characterized for energy response, angular dependency of response, and effect of accumulated dose on sensitivity and some inherent properties of MOSFETs. The doses determined both by thermoluminescence dosimetry (TLD) and MOSFETs in clinical situation were evaluated and compared to expected doses determined by calculation. Results: It was observed that a standard calibration of 0.01 Gy/mV gave MOSFET determined doses which agreed with expected doses to within 5% at the 95% confidence limit for photon beams from 6 to 25 MV and electron beams from 5 to 14 MeV. An energy-dependent variation in response of up to 28% was observed between two orientations of a MOSFET. The MOSFET doses compared very well with the doses estimated by TLDs, and the patients tolerated MOSFETs very well. A standard deviation of 3.9% between expected dose and MOSFET determined dose was observed, while for TLDs the standard deviation was 5.1%. The advantages and disadvantages of using MOSFETs for clinical dosimetry are discussed in detail. Conclusion: It was concluded that MOSFETs can be used as clinical dosimeters and can be a good alternative to TLDs. However, they have limitations under certain clinical situations

  20. Dielectric relaxation in biological systems physical principles, methods, and applications

    CERN Document Server

    Feldman, Yuri

    2015-01-01

    This title covers the theoretical basis and practical aspects of the study of dielectric properties of biological systems, such as water, electrolyte and polyelectrolytes, solutions of biological macromolecules, cells suspensions and cellular systems.

  1. [Detection of ciguatoxins: advantages and drawbacks of different biological methods].

    Science.gov (United States)

    Boydron-Le Garrec, Raphaële; Benoit, Evelyne; Sauviat, Martin-Pierre; Laurent, Dominique

    2005-01-01

    Ciguatera is a seafood intoxication that results from ingestion of reef fish contaminated with ciguatoxins at levels orally toxic for humans. Precursors of those toxins, gambiertoxins, are produced by benthic dinoflagellates (genus Gambierdiscus), and then accumulated and biotransformed by herbivorous and carnivorous fishes into ciguatoxins, more toxic for humans. In the absence of specific treatment, that disease remains a health problem with otherwise adverse socio-economic impacts. Thus a cost-effective means of detecting ciguatoxins in fish has long been searched for. Many assays have been developed, including in vivo, in vitro, chemical or immunochemical approaches. This review focuses on some biological methods, from the well-standardised mouse assay to the specific radio-labelled ligand binding assay that is performed on rat brain synaptosomes. In addition to the mouse, the chick and the mongoose were still recently used, in particular for preliminary tests before ciguatoxin extraction from fish, since assays in these animals can directly assay the whole flesh. In contrast, various other in vivo methods, such as the kitten, mosquito and diptera larvae assays, were abandoned despite their interesting results. Finally, the mouse neuroblastoma and rat brain synaptosome assays, carried out in vitro as alternative approaches to animal-using assays, are highly sensitive and much more specific than the in vivo methods to detect ciguatoxins.

  2. Thermoluminescence albedo-neutron dosimetry

    International Nuclear Information System (INIS)

    Strand, T.; Storruste, A.

    1986-10-01

    The report discusses neutron detection with respect to dosimetry and compares different thermoluminescent dosimetry materials for neutron dosimetry. Construction and calibration of a thermoluminescence albedo neutron dosemeter, developed by the authors, is described

  3. Can mixed assessment methods make biology classes more equitable?

    Science.gov (United States)

    Cotner, Sehoya; Ballen, Cissy J

    2017-01-01

    Many factors have been proposed to explain the attrition of women in science, technology, engineering and math fields, among them the lower performance of women in introductory courses resulting from deficits in incoming preparation. We focus on the impact of mixed methods of assessment, which minimizes the impact of high-stakes exams and rewards other methods of assessment such as group participation, low-stakes quizzes and assignments, and in-class activities. We hypothesized that these mixed methods would benefit individuals who otherwise underperform on high-stakes tests. Here, we analyze gender-based performance trends in nine large (N > 1000 students) introductory biology courses in fall 2016. Females underperformed on exams compared to their male counterparts, a difference that does not exist with other methods of assessment that compose course grade. Further, we analyzed three case studies of courses that transitioned their grading schemes to either de-emphasize or emphasize exams as a proportion of total course grade. We demonstrate that the shift away from an exam emphasis consequently benefits female students, thereby closing gaps in overall performance. Further, the exam performance gap itself is reduced when the exams contribute less to overall course grade. We discuss testable predictions that follow from our hypothesis, and advocate for the use of mixed methods of assessments (possibly as part of an overall shift to active learning techniques). We conclude by challenging the student deficit model, and suggest a course deficit model as explanatory of these performance gaps, whereby the microclimate of the classroom can either raise or lower barriers to success for underrepresented groups in STEM.

  4. Can mixed assessment methods make biology classes more equitable?

    Directory of Open Access Journals (Sweden)

    Sehoya Cotner

    Full Text Available Many factors have been proposed to explain the attrition of women in science, technology, engineering and math fields, among them the lower performance of women in introductory courses resulting from deficits in incoming preparation. We focus on the impact of mixed methods of assessment, which minimizes the impact of high-stakes exams and rewards other methods of assessment such as group participation, low-stakes quizzes and assignments, and in-class activities. We hypothesized that these mixed methods would benefit individuals who otherwise underperform on high-stakes tests. Here, we analyze gender-based performance trends in nine large (N > 1000 students introductory biology courses in fall 2016. Females underperformed on exams compared to their male counterparts, a difference that does not exist with other methods of assessment that compose course grade. Further, we analyzed three case studies of courses that transitioned their grading schemes to either de-emphasize or emphasize exams as a proportion of total course grade. We demonstrate that the shift away from an exam emphasis consequently benefits female students, thereby closing gaps in overall performance. Further, the exam performance gap itself is reduced when the exams contribute less to overall course grade. We discuss testable predictions that follow from our hypothesis, and advocate for the use of mixed methods of assessments (possibly as part of an overall shift to active learning techniques. We conclude by challenging the student deficit model, and suggest a course deficit model as explanatory of these performance gaps, whereby the microclimate of the classroom can either raise or lower barriers to success for underrepresented groups in STEM.

  5. Neutron dosimetry using proportional counters with tissue equivalent walls

    International Nuclear Information System (INIS)

    Kerviller, H. de

    1965-01-01

    The author reminds the calculation method of the neutron absorbed dose in a material and deduce of it the conditions what this material have to fill to be equivalent to biological tissues. Various proportional counters are mode with walls in new tissue equivalent material and filled with various gases. The multiplication factor and neutron energy response of these counters are investigated and compared with those obtained with ethylene lined polyethylene counters. The conditions of working of such proportional counters for neutron dosimetry in energy range 10 -2 to 15 MeV are specified. (author) [fr

  6. Radiation dosimetry in nuclear medicine

    International Nuclear Information System (INIS)

    Stabin, M.G.; Tagesson, M.; Ljungberg, M.; Strand, S.E.; Thomas, S.R.

    1999-01-01

    Radionuclides are used in nuclear medicine in a variety of diagnostic and therapeutic procedures. A knowledge of the radiation dose received by different organs in the body is essential to an evaluation of the risks and benefits of any procedure. In this paper, current methods for internal dosimetry are reviewed, as they are applied in nuclear medicine. Particularly, the Medical Internal Radiation Dose (MIRD) system for dosimetry is explained, and many of its published resources discussed. Available models representing individuals of different age and gender, including those representing the pregnant woman are described; current trends in establishing models for individual patients are also evaluated. The proper design of kinetic studies for establishing radiation doses for radiopharmaceuticals is discussed. An overview of how to use information obtained in a dosimetry study, including that of the effective dose equivalent (ICRP 30) and effective dose (ICRP 60), is given. Current trends and issues in internal dosimetry, including the calculation of patient-specific doses and in the use of small scale and microdosimetry techniques, are also reviewed

  7. Methods for implementation of in vivo dosimetry (entrance dose) using thermoluminescent dosimeters during radiotherapy treatment with photon beam

    International Nuclear Information System (INIS)

    Barsanelli, Cristiane

    2006-01-01

    Selection, calibration procedure to convert TLD signal into absorbed dose and physical characteristics at the thermoluminescent dosimeters, as well as the determination of correction factors and the methodology to determine expected entrance dose, are described in this work. Practical aspects and the utility of entrance dose measures with thermoluminescent dosimeters were investigated, as well as the exactness and the reproducibility of the daily dose release. The entrance dose measures were performed in five patients with diagnosis of breast cancer treated with a 6 MV photon beam. The measured dose and the expected dose values agreed in ± 5%, due to excellent treatment equipment stability, to automatic verification system and the good exactness in the daily treatment adjustment. Good precision can be achieved when the correction factors for each parameter of influence in the dosimeter response are carefully determined and applied to convert the thermoluminescent signal into absorbed dose. The study demonstrates the viability of thermoluminescent dosimeters use for in vivo dosimetry and its utility as part of a quality assurance program in a radiation therapy service. (author)

  8. Aircrew personnel dosimetry at airline companies in the Czech Republic. Selection of the method and its experimental testing

    International Nuclear Information System (INIS)

    Spurny, F.; Malusek, A.; Kovar, I.; Turek, K.; Vlcek, B.; Hlavaty, V.; Kolar, B

    2002-01-01

    The report gives the results of the first stages of analysis of the problem, performed based on a contract between the Czech airline company CSA and the Radiation Dosimetry Department, Institute of Nuclear Physics, Academy of Sciences of the Czech Republic. First, the contributions of the aircraft type and of the flight route to the aircrew radiation burden was investigated based on 1997 and 1998 data. At the same time, the effect of variations in the flight parameters on the exposure level was examined based on calculations by using an internationally recognized computer code. In the next part of the report, the results of measurement of the aircrew exposure level performed during the period of March to November 1999 are given and analyzed. The measurements encompassed 8 European flight routes, 2 routes over the northern regions of the Atlantic and one route to south-eastern Asia. Data were obtained for the low-LET component (mostly high-energy electrons and protons) as well as the high-LET component (mostly neutrons). To refine the interpretation of the data, calibration measurements were performed in the reference fields of high energy radiations at CERN. The results of measurement were compared with the results of calculation by the CARI code. The data provided by the latest CARI 6 version approach the observed values reasonably closely. (author)

  9. Standardized physics-dosimetry for US pressure vessel cavity surveillance programs

    International Nuclear Information System (INIS)

    Ruddy, F.H.; McElroy, W.N.; Lippincott, E.P.

    1984-01-01

    This paper summarizes the applications of ASTM standard methods, guides and practices to define the selection and deployment of recommended dosimetry sets, the selection of dosimetry capsules and thermal neutron shields, the placement of dosimetry, the methods of measurement of dosimetry sensor reaction products, data analysis procedures, and uncertainty evaluation procedures. It also describes the validation of these standards both by in-reactor testing of advanced PV cavity surveillance physics-dosimetry and by data development. The use of these standards to guide selection and development of advanced dosimetry sets for commercial reactors is also summarized. (Auth.)

  10. Cellular dosimetry

    International Nuclear Information System (INIS)

    Humm, J.L.; Chin, L.M.

    1989-01-01

    Radiation dose is a useful predictive parameter for describing radiation toxicity in conventional radiotherapy. Traditionally, in vitro radiation biology dose-effect relations are expressed in the form of cell survival curves, a semilog plot of cell survival versus dose. However, the characteristic linear or linear quadratic survival curve shape, for high- and low-LET radiations respectively, is only strictly valid when the radiation dose is uniform across the entire target population. With an external beam of 60 Co gamma rays or x-rays, a uniform field may be readily achievable. When radionuclides are incorporated into a cell milieu, several new problems emerge which can result in a departure from uniformity in energy deposition throughout a cell population. This nonuniformity can have very important consequences for the shape of the survival curve. Cases in which perturbations of source uniformity may arise include: 1. Elemental sources may equilibrate in the cell medium with partition coefficients between the extracellular, cytosol, and nuclear compartments. The effect of preferential cell internalization or binding to cell membrane of some radionuclides can increase or decrease the slope of the survival curve. 2. Radionuclides bound to antibodies, hormones, metabolite precursors, etc., may result in a source localization pattern characteristic of the carrier agent, i.e., the sources may bind to cell surface receptors or antigens, be internalized, bind to secreted antigen concentrated around a fraction of the cell population, or become directly incorporated into the cell DNA. We propose to relate the distribution of energy deposition in cell nuclei to biological correlates of cellular inactivation. The probability of each cell's survival is weighted by its individual radiation burden, and the summation of these probabilities for the cell population can be used to predict the number or fraction of cell survivors

  11. Electron spin resonance (ESR) spectroscopy applied to radiation dosimetry and other fields

    International Nuclear Information System (INIS)

    Schneider, C.C.J.

    1994-12-01

    A short introduction to the theory and practice of ESR spectroscopy is given. ESR alanine dosimetry for low and high LET (linear energy transfer) ionising radiation is described, indicating its advantages over traditional methods. Problems arising in the therapy dose range (below 5 Gy), and possible future developments, are mentioned. The application of ESR to the radiation processing of materials and foodstuffs, to geological dating, biology, molecular chemistry and to medicine is discussed. Some examples of chemical analyses are also presented. (orig.)

  12. EPR dosimetry - present and future

    International Nuclear Information System (INIS)

    Regulla, D.F.

    1999-01-01

    In the past, IAEA has played a central role in stipulating research and development in EPR high-dose standardisation as well as co-ordinating and organising international dose intercomparison programs, within the Member States of the United Nations from the mid-seventies till today. The future tasks of EPR dosimetry seem to tend towards different subjects such as biomarkers, biological radiation effects, post-accident dose reconstruction in the environment, and retrospective human dosimetry. The latter may be considered a promising tool for epidemiology on the way to re-define radiation risk of man for chronicle radiation exposures, based on e.g. South Ural civil population and radiation workers. There are on-going international activities in the field of standardising high-level dosimetry by the American Standards on Testing and Materials (ASTM), and the International Organisation of Standards (ISO) as well as those of the International Commission on Radiation Units and Measurements (ICRU) considering the establishment of relevant recommendations concerning industrial radiation processing, but also human dose reconstruction. (author)

  13. EPR Dosimetry - Present and Future

    Energy Technology Data Exchange (ETDEWEB)

    Regulla, D.F. [GSF - National Research Centre for Environment and Health, Institute of Radiation Protection, 85764 Neuherberg (Germany)

    1999-07-01

    In the past, IAEA has played a central role in stipulating research and development in EPR high-dose standardisation as well as in coordinating and organising international dose intercomparison programs, within the Member States of the United Nations from the mid-seventies till today. The future tasks of EPR dosimetry seem to tend towards different subjects such as bio markers, biological radiation effects, post-accident dose reconstruction in the environment, and retrospective human dosimetry. The latter may be considered a promising tool for epidemiology on the way to re-define radiation risk of man for chronicle radiation exposures, based on e.g. South Ural civil population and radiation workers. There are on-going international activities in the field of standardising high-level dosimetry by the American Standards on Testing and Materials (Astm), and by the International Organisation of Standards (ISO). The International Commission on Radiation Units and Measurements (ICRU) is considering the establishment of relevant recommendations concerning industrial radiation processing, but also human dose reconstruction. (Author)

  14. EPR Dosimetry - Present and Future

    International Nuclear Information System (INIS)

    Regulla, D.F.

    1999-01-01

    In the past, IAEA has played a central role in stipulating research and development in EPR high-dose standardisation as well as in coordinating and organising international dose intercomparison programs, within the Member States of the United Nations from the mid-seventies till today. The future tasks of EPR dosimetry seem to tend towards different subjects such as bio markers, biological radiation effects, post-accident dose reconstruction in the environment, and retrospective human dosimetry. The latter may be considered a promising tool for epidemiology on the way to re-define radiation risk of man for chronicle radiation exposures, based on e.g. South Ural civil population and radiation workers. There are on-going international activities in the field of standardising high-level dosimetry by the American Standards on Testing and Materials (Astm), and by the International Organisation of Standards (ISO). The International Commission on Radiation Units and Measurements (ICRU) is considering the establishment of relevant recommendations concerning industrial radiation processing, but also human dose reconstruction. (Author)

  15. Skeletal dosimetry models for alpha-particles for use in molecular radiotherapy

    Science.gov (United States)

    Watchman, Christopher J.

    Molecular radiotherapy is a cancer treatment methodology whereby a radionuclide is combined with a biologically active molecule to preferentially target cancer cells. Alpha-particle emitting radionuclides show significant potential for use in molecular radiotherapy due to the short range of the alpha-particles in tissue and their high rates of energy deposition. Current radiation dosimetry models used to assess alpha emitter dose in the skeleton were developed originally for occupational applications. In medical dosimetry, individual variability in uptake, translocation and other biological factors can result in poor correlation of clinical outcome with marrow dose estimates determined using existing skeletal models. Methods presented in this work were developed in response to the need for dosimetry models which account for these biological and patient-specific factors. Dosimetry models are presented for trabecular bone alpha particle dosimetry as well as a model for cortical bone dosimetry. These radiation transport models are the 3D chord-based infinite spongiosa transport model (3D-CBIST) and the chord-based infinite cortical transport model (CBICT), respectively. Absorbed fraction data for several skeletal tissues for several subjects are presented. Each modeling strategy accounts for biological parameters, such as bone marrow cellularity, not previously incorporated into alpha-particle skeletal dosimetry models used in radiation protection. Using these data a study investigating the variability in alpha-particle absorbed fractions in the human skeleton is also presented. Data is also offered relating skeletal tissue masses in individual bone sites for a range of ages. These data are necessary for dose calculations and have previously only been available as whole body tissue masses. A revised 3D-CBIST model is also presented which allows for changes in endosteum thickness to account for revised target cell location of tissues involved in the radiological

  16. Methods for isolation and viability assessment of biological organisms

    Science.gov (United States)

    Letant, Sonia Edith; Baker, Sarah Elyse; Bond, Tiziana; Chang, Allan Shih-Ping

    2015-02-03

    Isolation of biological or chemical organisms can be accomplished using a surface enhanced Raman scattering (SERS) system. The SERS system can be a single or a stacked plurality of photonic crystal membranes with noble-metal lined through pores for flowing analyte potentially containing the biological or chemical organisms. The through pores can be adapted to trap individual biological or chemical organisms and emit SERS spectra, which can then be detected by a detector and further analyzed for viability of the biological or chemical organism.

  17. Proceedings of the 5. symposium on neutron dosimetry. Beam dosimetry

    International Nuclear Information System (INIS)

    Schraube, H.; Burger, G.; Booz, J.

    1985-01-01

    Proceedings of the fifth symposium on neutron dosimetry, organized at Neuherberg, 17-21 September 1984, by the Commission of the European Communities and the GSF Neuherberg, with the co-sponsorship of the US Department of Energy, Office of Health and Environmental Research. The proceedings deal with research on concepts, instruments and methods in radiological protection for neutrons and mixed neutron-gamma fields, including the generation, collection and evaluation of new dosimetric data, the derivation of relevant radiation protection quantitites, and the harmonization of experimental methods and instrumentation by intercomparison programmes. Besides radiation protection monitoring, the proceedings also report on the improvement of neutron beam dosimetry in the fields of radiobiology and radiation therapy

  18. Dosimetry techniques applied to thermoluminescent age estimation

    International Nuclear Information System (INIS)

    Erramli, H.

    1986-12-01

    The reliability and the ease of the field application of the measuring techniques of natural radioactivity dosimetry are studied. The natural radioactivity in minerals in composed of the internal dose deposited by alpha and beta radiations issued from the sample itself and the external dose deposited by gamma and cosmic radiations issued from the surroundings of the sample. Two technics for external dosimetry are examined in details. TL Dosimetry and field gamma dosimetry. Calibration and experimental conditions are presented. A new integrated dosimetric method for internal and external dose measure is proposed: the TL dosimeter is placed in the soil in exactly the same conditions as the sample ones, during a time long enough for the total dose evaluation [fr

  19. Dosimetry for radiation processing

    International Nuclear Information System (INIS)

    Kumar, A.; Reddy, A.R.

    1994-01-01

    The last few years have seen a significant increase in the use of ionising radiation in industrial processes and also international trade in irradiated products. With this, the demand for internationally accepted dosimetric techniques, accredited to international standards has also increased which is further stimulated by the emergence of ISO-9000 series of standards in industries. The present paper describes some of the important dosimetric techniques used in radiation processing, the role of IAEA in evolving internationally accepted standards and work carried out at the Defence Laboratories, Jodhpur in the development of a cheap, broad dose range and simple dosimeter for routine dosimetry. For this polyhydroxy alcohols viz., mannitol, sorbitol and inositol were studied using the spectrophotometric read out method. Out of the alcohols studied mannitol was found to be most promising covering a dose range of 0.01 kGy - 100 kGy. (author). 26 refs., 3 figs., 1 tab

  20. Nuclear accident dosimetry

    International Nuclear Information System (INIS)

    1982-01-01

    The film presents statistical data on criticality accidents. It outlines past IAEA activities on criticality accident dosimetry and the technical documents that resulted from this work. The film furthermore illustrates an international comparison study on nuclear accident dosimetry conducted at the Atomic Energy Research Establishment, Harwell, United Kingdom

  1. Personal dosimetry in Kazakhstan

    International Nuclear Information System (INIS)

    Khvoshnyanskaya, I.R.; Vdovichenko, V.G.; Lozbin, A.Yu.

    2003-01-01

    KATEP-AE Radiation Laboratory is the first organization in Kazakhstan officially licensed by the Kazakhstan Atomic Energy Committee to provide individual dosimetry services. The Laboratory was established according to the international standards. Nowadays it is the largest company providing personal dosimetry services in the Republic of Kazakhstan. (author)

  2. Nuclear accident dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1983-12-31

    The film presents statistical data on criticality accidents. It outlines past IAEA activities on criticality accident dosimetry and the technical documents that resulted from this work. The film furthermore illustrates an international comparison study on nuclear accident dosimetry conducted at the Atomic Energy Research Establishment, Harwell, United Kingdom

  3. Neutron personal dosimetry: state-of-art

    International Nuclear Information System (INIS)

    Spurný, František

    2005-03-01

    State-of-art of the personal neutron dosimetry is presented, analysed and discussed. Particular attention is devoted to the problems of this type of the dosimetry of external exposure for radiation fields at nuclear power plants. A review of general problems of neutron dosimetry is given and the active individual dosimetry methods available and/or in the stage of development are briefly reviewed. Main attention is devoted to the analysis of the methods available for passive individual neutron dosimetry. The characteristics of these dosemeters were studied and are compared: their energy response functions, detection thresholds and the highest detection limits, the linearity of response, the influence of environmental factors, etc. Particular attention is devoted to their behavior in reactor neutron fields. It is concluded that the choice of the neutron personal dosemeter depends largely on the conditions in which the instrument should be used (neutron spectrum, the level of exposure and the exposure rate, etc.). The results obtained with some of these dosemeters during international intercomparisons are also presented. Particular attention is paid to the personal neutron dosimeter developed and routinely used by National Personal Dosimetry Service Ltd. in the Czech Republic. (author)

  4. 100 years of solid state dosimetry and radiation protection dosimetry

    International Nuclear Information System (INIS)

    Bartlett, David T.

    2008-01-01

    The use of solid state detectors in radiation dosimetry has passed its 100th anniversary. The major applications of these detectors in radiation dosimetry have been in personal dosimetry, retrospective dosimetry, dating, medical dosimetry, the characterization of radiation fields, and also in microdosimetry and radiobiology research. In this introductory paper for the 15th International Conference, I shall speak of the history of solid state dosimetry and of the radiation measurement quantities that developed at the same time, mention some landmark developments in detectors and applications, speak a bit more about dosimetry and measurement quantities, and briefly look at the past and future

  5. Simulation-extrapolation method to address errors in atomic bomb survivor dosimetry on solid cancer and leukaemia mortality risk estimates, 1950-2003

    Energy Technology Data Exchange (ETDEWEB)

    Allodji, Rodrigue S.; Schwartz, Boris; Diallo, Ibrahima; Vathaire, Florent de [Gustave Roussy B2M, Radiation Epidemiology Group/CESP - Unit 1018 INSERM, Villejuif Cedex (France); Univ. Paris-Sud, Villejuif (France); Agbovon, Cesaire [Pierre and Vacances - Center Parcs Group, L' artois - Espace Pont de Flandre, Paris Cedex 19 (France); Laurier, Dominique [Institut de Radioprotection et de Surete Nucleaire (IRSN), DRPH, SRBE, Laboratoire d' epidemiologie, BP17, Fontenay-aux-Roses Cedex (France)

    2015-08-15

    Analyses of the Life Span Study (LSS) of Japanese atomic bombing survivors have routinely incorporated corrections for additive classical measurement errors using regression calibration. Recently, several studies reported that the efficiency of the simulation-extrapolation method (SIMEX) is slightly more accurate than the simple regression calibration method (RCAL). In the present paper, the SIMEX and RCAL methods have been used to address errors in atomic bomb survivor dosimetry on solid cancer and leukaemia mortality risk estimates. For instance, it is shown that using the SIMEX method, the ERR/Gy is increased by an amount of about 29 % for all solid cancer deaths using a linear model compared to the RCAL method, and the corrected EAR 10{sup -4} person-years at 1 Gy (the linear terms) is decreased by about 8 %, while the corrected quadratic term (EAR 10{sup -4} person-years/Gy{sup 2}) is increased by about 65 % for leukaemia deaths based on a linear-quadratic model. The results with SIMEX method are slightly higher than published values. The observed differences were probably due to the fact that with the RCAL method the dosimetric data were partially corrected, while all doses were considered with the SIMEX method. Therefore, one should be careful when comparing the estimated risks and it may be useful to use several correction techniques in order to obtain a range of corrected estimates, rather than to rely on a single technique. This work will enable to improve the risk estimates derived from LSS data, and help to make more reliable the development of radiation protection standards. (orig.)

  6. Dosimetry for radiation processing

    International Nuclear Information System (INIS)

    McLaughlin, W.L.; Boyd, A.W.; Chadwick, K.H.; McDonald, J.C.; Miller, A.

    1989-01-01

    Radiation processing is a relatively young industry with broad applications and considerable commercial success. Dosimetry provides an independent and effective way of developing and controlling many industrial processes. In the sterilization of medical devices and in food irradiation, where the radiation treatment impacts directly on public health, the measurements of dose provide the official means of regulating and approving its use. In this respect, dosimetry provides the operator with a means of characterizing the facility, of proving that products are treated within acceptable dose limits and of controlling the routine operation. This book presents an up-to-date review of the theory, data and measurement techniques for radiation processing dosimetry in a practical and useful way. It is hoped that this book will lead to improved measurement procedures, more accurate and precise dosimetry and a greater appreciation of the necessity of dosimetry for radiation processing. (author)

  7. Comparative study of skeletal dosimetry methods in therapeutic schemes with Re186 HEDP and Sm153 EDTMP

    International Nuclear Information System (INIS)

    Papanikolos, G.; Lyra, M.; Kontogeorgakos, D.; Jordanou, J.; Vlahos, L.; Limouris, G.

    2005-01-01

    Full text: Optimum therapeutic management of patients suffering from metastatic bone pain, requires accurate calculations concerning absorbed dose by metastatic lesions and other critical organs, such as red marrow. Mean absorbed dose, which is the current parameter used to predict the efficacy of the treatment, can either overestimate or underestimate, actual doses delivered in these organs/tissues of interest (TOIs). This study presents differences in dosimetric calculations derived utilizing parameters from different sources (MIRDOSE3, MIRD Pamphlet No 11 and S values published by Bouchet et al.), in therapeutic schemes with Re186HEDP and Sm153EDTMP. A set of planar scintigraphic images for 2 groups of patients (1 for Re 186 patients and the other for Sm153 patients) were obtained in the following sequence: 2 during the first 24h post injection (the last of which at 24h post injection) and 2 more from 24h 7d post injection. Processing of the obtained images utilizing ROI quantitative methods, previously calibrated with waterphantom measurements, determine residence times and radionuclide uptakes not only by TOIs but by specific skeletal sites as well. Dosimetric calculations were performed using MIRDOSE3 computer code, S values from MIRD Pamphlet No 11 and site specific Re 186 and Sm 153 S values for several source target combinations within trabecular and cortical bone, reported by Bouchet et al. (J Nucl Med 2000; 41:189 212), along with cumulative site specific activities derived from values obtained by image processing. Skeletal averaged Re 186 and Sm 153 S values were also used from the aforementioned study by Bouchet et al. Time activity curves for various skeletal sites were generated for both groups of patients. Absorbed dose distributions along with time dose rate curves were derived for both red marrow and different regions of the skeleton. Comparisons are made between these parameters and mean absorbed doses calculated using skeletal averaged S values

  8. Cellular dosimetry in nuclear medicine imaging: training

    International Nuclear Information System (INIS)

    Gardin, I.; Faraggi, M.; Stievenart, J.L.; Le Guludec, D.; Bok, B.

    1998-01-01

    The radionuclides used in nuclear medicine imaging emit not only diagnostically useful photons, but also energy electron emissions, responsible for dose heterogeneity at the cellular level. The mean dose delivered to the cell nucleus by electron emissions of 99m Tc, 123 I, 111 In, 67 Ga, and 201 Tl, has been calculated, for the cell nucleus, a cytoplasmic and a cell membrane distribution of radioactivity. This model takes into account both the self-dose which results from the radionuclide located in the target cell, and the cross-dose, which comes from the surrounding cells. The results obtained by cellular dosimetry (D cel ) have been compared with those obtained with conventional dosimetry (D conv ), by assuming the same amount of radioactivity per cell. Cellular dosimetry shows, for a cytoplasmic and a cell membrane distributions of radioactivity, that the main contribution to the dose to the cell nucleus, comes from the surrounding cells. On the other hand, for a cell nucleus distribution of radioactivity, the self-dose is not negligible and may be the main contribution. The comparison between cellular and conventional dosimetry shows that D cel /D conv ratio ranges from 0.61 and O.89, in case of a cytoplasmic and a cell membrane distributions of radioactivity, depending on the radionuclide and cell dimensions. Thus, conventional dosimetry slightly overestimates the mean dose to the cell nucleus. On the other hand, D cel /D conv ranges from 1.1 to 75, in case of a cell nucleus distribution of radioactivity. Conventional dosimetry may strongly underestimates the absorbed dose to the nucleus, when radioactivity is located in the nucleus. The study indicates that in nuclear medicine imaging, cellular dosimetry may lead to a better understanding of biological effects of radiopharmaceuticals. (authors)

  9. Present status and expected progress in radiation processing dosimetry

    DEFF Research Database (Denmark)

    Kovács, A.; Miller, A.

    2004-01-01

    The paper describes the present status of radiation processing dosimetry including the methods used most widely in gamma- and electron processing as well as the new methods under development or introduction. The recent trends with respect to calibrationof routine dosimetry systems as well...

  10. Thermoluminescence in medical dosimetry; Termoluminiscencia en dosimetria medica

    Energy Technology Data Exchange (ETDEWEB)

    Rivera, T., E-mail: trivera@ipn.mx [IPN, Centro de Investigacion en Ciencia Aplicada y Tecnologia Avanzada, Av. Legaria 694, Col. Irrigacion, 11500 Mexico D. F. (Mexico)

    2011-10-15

    The dosimetry by thermoluminescence (Tl) is applied in the entire world for the dosimetry of ionizing radiations specially to personal and medical dosimetry. This dosimetry method has been very interesting for measures in vivo because the Tl dosimeters have the advantage of being very sensitive in a very small volume and they are also equivalent to tissue and they do not need additional accessories (for example, cable, electrometer, etc.) The main characteristics of the diverse Tl materials to be used in the radiation measures and practical applications are: the Tl curve, the share homogeneity, the signal stability after the irradiation, precision and exactitude, the response in function with the dose and the energy influence. In this work a brief summary of the advances of the radiations dosimetry is presented by means of the thermally stimulated luminescence and its application to the dosimetry in radiotherapy. (Author)

  11. Synthetic Methods and Exploring Biological Potential of Various Substituted Quinoxalin-2-one Derivatives

    OpenAIRE

    Mohammad Asif

    2016-01-01

    Substituted quinoxaline have considerable interest in chemistry, biology and pharmacology. Quinoxaline derivatives are capable with variety of biological activities and possess different biological activities, of which the most potent are anti-microbial, analgesic and anti-inflammatory activities. It facilitated the researchers to develop various methods for their synthesis and their applications. In this review represented different methods of synthesis, reactivity and various biological act...

  12. A magnetic method to concentrate and trap biological targets

    KAUST Repository

    Li, Fuquan; Kosel, Jü rgen

    2012-01-01

    Magnetoresistive sensors in combination with magnetic particles have been used in biological applications due to, e.g., their small size and high sensitivity. A growing interest is to integrate magnetoresistive sensors with microchannels

  13. The Vinca dosimetry experiment

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1962-03-15

    On 15 October 1958 there occurred a very brief uncontrolled run of the zero-power reactor at the Boris Kidric Institute of Nuclear Science, Vinca, near Belgrade, Yugoslavia. During this run six persons received various doses of radiation. They were subsequently given medical treatment of a novel kind at the Curie Hospital, Paris. In atomic energy operations to date, very few accidents involving excessive radiation exposure to human beings have occurred. In fact, the cases of acute radiation injury are limited to about 30 known high exposures, few of which were in the lethal or near-lethal range. Since direct experiment to determine the effects of ionizing radiation on man is unacceptable, information on these effects has to be based on a consideration of data relating to accidental exposures, viewed in the light of the much more extensive data obtained from experiments on animals. Therefore, any direct information on the effects of radiation on humans is very valuable. The international dosimetry project described in this report was carried out at Vinca, Yugoslavia, under the auspices of the International Atomic Energy Agency to determine the precise amount of radiation to which the persons had been exposed during the accident. These dosimetry data, together with the record of the carefully observed clinical effects, are of importance both for the scientific study of radiation effects on man and for the development of methods of therapy. The experiment and measurements were carried out at the end of April 1960. The project formed part of the Agency's research programme in the field of health and safety. The results of the experiment are made available through this report to all Member States.

  14. The Vinca dosimetry experiment

    International Nuclear Information System (INIS)

    1962-03-01

    On 15 October 1958 there occurred a very brief uncontrolled run of the zero-power reactor at the Boris Kidric Institute of Nuclear Science, Vinca, near Belgrade, Yugoslavia. During this run six persons received various doses of radiation. They were subsequently given medical treatment of a novel kind at the Curie Hospital, Paris. In atomic energy operations to date, very few accidents involving excessive radiation exposure to human beings have occurred. In fact, the cases of acute radiation injury are limited to about 30 known high exposures, few of which were in the lethal or near-lethal range. Since direct experiment to determine the effects of ionizing radiation on man is unacceptable, information on these effects has to be based on a consideration of data relating to accidental exposures, viewed in the light of the much more extensive data obtained from experiments on animals. Therefore, any direct information on the effects of radiation on humans is very valuable. The international dosimetry project described in this report was carried out at Vinca, Yugoslavia, under the auspices of the International Atomic Energy Agency to determine the precise amount of radiation to which the persons had been exposed during the accident. These dosimetry data, together with the record of the carefully observed clinical effects, are of importance both for the scientific study of radiation effects on man and for the development of methods of therapy. The experiment and measurements were carried out at the end of April 1960. The project formed part of the Agency's research programme in the field of health and safety. The results of the experiment are made available through this report to all Member States

  15. Development of a new method to characterize low-to-medium energy X-ray beams (E≤150 keV) used in dosimetry

    International Nuclear Information System (INIS)

    Deloule, Sybelle

    2014-01-01

    In the field of dosimetry, the knowledge of the whole photon fluence spectrum is an essential parameter. In the low-to-medium energy range (i.e. E≤150 keV), the LNHB possess 5 X-ray tubes and iodine-125 brachytherapy seeds, both emitting high fluence rates. The performance of calculation (either Monte Carlo codes or deterministic software) is flawed by increasing uncertainties on fundamental parameters at low energies, and modelling issues. Therefore, direct measurement using a high purity germanium is preferred, even though it requires a time-consuming set-up and mathematical methods to infer impinging spectrum from measured ones (such as stripping, model-fitting or Bayesian inference). Concerning brachytherapy, the knowledge of the seed's parameters has been improved. Moreover, various calculated X-ray tube fluence spectra have been compared to measured ones, after unfolding. The results of all these methods have then be assessed, as well as their impact on dosimetric parameters. (author) [fr

  16. Single-molecule experiments in biological physics: methods and applications.

    Science.gov (United States)

    Ritort, F

    2006-08-16

    I review single-molecule experiments (SMEs) in biological physics. Recent technological developments have provided the tools to design and build scientific instruments of high enough sensitivity and precision to manipulate and visualize individual molecules and measure microscopic forces. Using SMEs it is possible to manipulate molecules one at a time and measure distributions describing molecular properties, characterize the kinetics of biomolecular reactions and detect molecular intermediates. SMEs provide additional information about thermodynamics and kinetics of biomolecular processes. This complements information obtained in traditional bulk assays. In SMEs it is also possible to measure small energies and detect large Brownian deviations in biomolecular reactions, thereby offering new methods and systems to scrutinize the basic foundations of statistical mechanics. This review is written at a very introductory level, emphasizing the importance of SMEs to scientists interested in knowing the common playground of ideas and the interdisciplinary topics accessible by these techniques. The review discusses SMEs from an experimental perspective, first exposing the most common experimental methodologies and later presenting various molecular systems where such techniques have been applied. I briefly discuss experimental techniques such as atomic-force microscopy (AFM), laser optical tweezers (LOTs), magnetic tweezers (MTs), biomembrane force probes (BFPs) and single-molecule fluorescence (SMF). I then present several applications of SME to the study of nucleic acids (DNA, RNA and DNA condensation) and proteins (protein-protein interactions, protein folding and molecular motors). Finally, I discuss applications of SMEs to the study of the nonequilibrium thermodynamics of small systems and the experimental verification of fluctuation theorems. I conclude with a discussion of open questions and future perspectives.

  17. Single-molecule experiments in biological physics: methods and applications

    International Nuclear Information System (INIS)

    Ritort, F

    2006-01-01

    I review single-molecule experiments (SMEs) in biological physics. Recent technological developments have provided the tools to design and build scientific instruments of high enough sensitivity and precision to manipulate and visualize individual molecules and measure microscopic forces. Using SMEs it is possible to manipulate molecules one at a time and measure distributions describing molecular properties, characterize the kinetics of biomolecular reactions and detect molecular intermediates. SMEs provide additional information about thermodynamics and kinetics of biomolecular processes. This complements information obtained in traditional bulk assays. In SMEs it is also possible to measure small energies and detect large Brownian deviations in biomolecular reactions, thereby offering new methods and systems to scrutinize the basic foundations of statistical mechanics. This review is written at a very introductory level, emphasizing the importance of SMEs to scientists interested in knowing the common playground of ideas and the interdisciplinary topics accessible by these techniques. The review discusses SMEs from an experimental perspective, first exposing the most common experimental methodologies and later presenting various molecular systems where such techniques have been applied. I briefly discuss experimental techniques such as atomic-force microscopy (AFM), laser optical tweezers (LOTs), magnetic tweezers (MTs), biomembrane force probes (BFPs) and single-molecule fluorescence (SMF). I then present several applications of SME to the study of nucleic acids (DNA, RNA and DNA condensation) and proteins (protein-protein interactions, protein folding and molecular motors). Finally, I discuss applications of SMEs to the study of the nonequilibrium thermodynamics of small systems and the experimental verification of fluctuation theorems. I conclude with a discussion of open questions and future perspectives. (topical review)

  18. The work of the 'Irradiation Damage' sub-group of the EURATOM Working Group on Research Reactor Dosimetry

    International Nuclear Information System (INIS)

    Genthon, J.P.

    1975-01-01

    The EURATOM Working Group on Reactor Dosimetry is investigating the problems of the dosimetry of radiation damage experiments. Papers have been published on the dosimetry of graphite and irradiation of metals: the model chosen, the quantities employed to express the fluences, numerical values, measurements, and measurement techniques. The ensuing work of the EURATOM Working Group of Reactor Dosimetry in these areas will deal with the measurement methods required for the dosimetry of radiation damage. (Auth.)

  19. Thiosemicarbazones: preparation methods, synthetic applications and biological importance

    International Nuclear Information System (INIS)

    Tenorio, Romulo P.; Goes, Alexandre J.S.; Lima, Jose G. de; Faria, Antonio R. de; Alves, Antonio J.; Aquino, Thiago M. de

    2005-01-01

    Thiosemicarbazones are a class of compounds known by their chemical and biological properties, such as antitumor, antibacterial, antiviral and antiprotozoal activity. Their ability to form chelates with metals has great importance in their biological activities. Their synthesis is very simple, versatile and clean, usually giving high yields. They are largely employed as intermediates, in the synthesis of others compounds. This article is a survey of some of these characteristics showing their great importance to organic and medicinal chemistry. (author)

  20. Analysis of biological materials by RBS and PIXE methods

    International Nuclear Information System (INIS)

    Latuszynski, A.; Maczka, D.; Kobzev, A. P.

    2002-01-01

    A problem of the exact determination of the element concentration in different substances is of essential significance, especially in medical, biological, as well as environment protection investigations. For this purpose some chemical and physical methods are used such as very sensitive and precise techniques: PIXE and RBS. The main advantage of those methods is the sensitivity of ppm level and very small sample amount necessary for carrying out the investigations. In this article the investigation results obtained by PIXE and RBS methods for the metal contents in cow milk (18 various samples were studied) as well as the heavy metal admixtures in the brain of the living domestic animals (6 cows, 6 dogs and 17 rats) are presented. The samples were prepared for the analysis in a liofilization process, then they were mixed with spectral pure graphite. The PIXE and RBS investigations were performed using a proton beam of about 2 mm diameter, intensity of about 10 nA and energy of 2.5 MeV from the Van-de-Graaff generator, FLNP, JINR, Dubna. The measurements of the characteristic spectrum were carried out by means of a Si (Li) detector with the resolution of 200 eV at the energy of 6,4 keV. Generally, in all samples of milk and brain we could identify 20 elements, among them 13 (C, N, O, P, Cl, K, Ca, Fe, Cu, Zn. Br, Rb, Sr) appeared in all of the studied samples. The difference in the concentration of the most of those elements between samples was in the range of 15 - 20 %. This indicates a good accuracy of the used methods of measurement. Especially our attention was paid to the presence of Sr, Rb and Br, practically in all the milk samples. This fact requires further investigations. Such elements as Pb, As, Ni, Co, Mn, V and Ti were found in some samples, including all samples coming from regions of a high urbanization. It is characteristic that the milk samples coming from villages located considerably far-away from cities and from communication tracks, practically

  1. Some aspects on neutron dosimetry

    International Nuclear Information System (INIS)

    Henaish, B.A.; Youssef, S.K.

    1988-01-01

    The American National Council on Radiation Protection and measurements (1) has recently issued a statement regarding dose limitation system for neutrons. The changes proposed in that statement presented substantial problems regarding the personnel exposure to neutrons and had pointed out the need to reassess an adequate current neutron dosimetry practice. Generally, the same types of dosimeters i.e. Nuclear Track (NTA films) and TLD-Albedo, have been used at major nuclear facilities over the past 15 years. here recently, other dosimetry methods such as track etch with polycarbonates such as CR-39 have been developed. However these should be recognized as local systems aiming to the development of better and more applicable dosimeters. 4 tab

  2. Gel dosimetry for conformal radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Gambarini, G [Department of Physics of the University and INFN, Milan (Italy)

    2005-07-01

    With the continuum development of conformal radio therapies, aimed at delivering high dose to tumor tissue and low dose to the healthy tissue around, the necessities has appeared of suitable improvement of dosimetry techniques giving the possibility of obtaining dose images to be compared with diagnostic images. Also if wide software has been developed for calculating dose distributions in the fields of various radiotherapy units, experimental verifications are necessary, in particular in the case of complex geometries in conformal radiotherapy. Gel dosimetry is a promising method for imaging the absorbed dose in tissue-equivalent phantoms, with the possibility of 3D reconstruction of the spatial dose distribution, with milli metric resolution. Optical imaging of gel dosimeters, based on visible light absorbance analysis, has shown to be a reliable technique for achieving dose distributions. (Author)

  3. Evaluation of the efficiency of different methods of personal dosimetry in vascular interventional radiology; Avaliação da eficiência de diferentes métodos de dosimetria pessoal em radiologia intervencionista vascular

    Energy Technology Data Exchange (ETDEWEB)

    Bacchim Neto, F.A., E-mail: fernando.bacchim@lnls.br [Laboratório Nacional de Luz Síncrotron (LNLS), Campinas-SP (Brazil). Centro Nacional de Pesquisa em Energia e Materiais; Alves, A.F.F.; Rosa, M.E.D. [Universidade Estadual Paulista Julio de Mesquita Filho (UNESP), Botucatu, SP (Brazil). Instituto de Biociências; Pina, D.R. [Universidade Estadual Paulista Julio de Mesquita Filho (UNESP), Botucatu, SP (Brazil). Departamento de Doenças Tropicais e Diagnóstico por Imagem

    2017-07-01

    Interventional Radiology - IR is the area of medicine that provides the largest occupational exposures. The dose values to which interventionists are exposed are difficult to standardize. The objective of the study is to perform a complete evaluation of occupational exposures and to determine the efficiency of different personal dosimetry methods used in IR. We evaluated the efficiencies of 6 different personal dosimetry methodologies used internationally to estimate the effective dose received by interventional professionals. And, based on this analysis, determine the characteristics of each methodology. One of the methods of personal dosimetry recommended by Brazilian legislation was the most conservative, overestimating, on average, the effective dose of professionals by up to 200%, reaching maximum values close to 400%. The most accurate method was that used in North America. This method did not overestimate the effective dose of the professionals more than a few percent and their standard deviation relative to the effective reference dose were the lowest. Based on these results, the choice of methodologies employing at least two dosimeters, one under and above protective aprons is recommended. In addition, in some situations where the dose in the hands may be high, additional dosimeters for this region are also recommended.

  4. Potential of discrete Gaussian edge feathering method for improving abutment dosimetry in eMLC-delivered segmented-field electron conformal therapy

    Energy Technology Data Exchange (ETDEWEB)

    Eley, John G.; Hogstrom, Kenneth R.; Matthews, Kenneth L.; Parker, Brent C.; Price, Michael J. [Department of Physics and Astronomy, Louisiana State University and Agricultural and Mechanical College, 202 Nicholson Hall, Tower Drive, Baton Rouge, Louisiana 70803-4001 (United States); Department of Physics and Astronomy, Louisiana State University and Agricultural and Mechanical College, 202 Nicholson Hall, Tower Drive, Baton Rouge, Louisiana 70803-4001 (United States) and Mary Bird Perkins Cancer Center, 4950 Essen Lane, Baton Rouge, Louisiana 70809-3482 (United States); Department of Physics and Astronomy, Louisiana State University and Agricultural and Mechanical College, 202 Nicholson Hall, Tower Drive, Baton Rouge, Louisiana 70803-4001 (United States); Department of Physics and Astronomy, Louisiana State University and Agricultural and Mechanical College, 202 Nicholson Hall, Tower Drive, Baton Rouge, Louisiana 70803-4001 (United States) and Mary Bird Perkins Cancer Center, 4950 Essen Lane, Baton Rouge, Louisiana 70809-3482 (United States)

    2011-12-15

    Purpose: The purpose of this work was to investigate the potential of discrete Gaussian edge feathering of the higher energy electron fields for improving abutment dosimetry in the planning volume when using an electron multileaf collimator (eMLC) to deliver segmented-field electron conformal therapy (ECT). Methods: A discrete (five-step) Gaussian edge spread function was used to match dose penumbras of differing beam energies (6-20 MeV) at a specified depth in a water phantom. Software was developed to define the leaf eMLC positions of an eMLC that most closely fit each electron field shape. The effect of 1D edge feathering of the higher energy field on dose homogeneity was computed and measured for segmented-field ECT treatment plans for three 2D PTVs in a water phantom, i.e., depth from the water surface to the distal PTV surface varied as a function of the x-axis (parallel to leaf motion) and remained constant along the y-axis (perpendicular to leaf motion). Additionally, the effect of 2D edge feathering was computed and measured for one radially symmetric, 3D PTV in a water phantom, i.e., depth from the water surface to the distal PTV surface varied as a function of both axes. For the 3D PTV, the feathering scheme was evaluated for 0.1-1.0-cm leaf widths. Dose calculations were performed using the pencil beam dose algorithm in the Pinnacle{sup 3} treatment planning system. Dose verification measurements were made using a prototype eMLC (1-cm leaf width). Results: 1D discrete Gaussian edge feathering reduced the standard deviation of dose in the 2D PTVs by 34, 34, and 39%. In the 3D PTV, the broad leaf width (1 cm) of the eMLC hindered the 2D application of the feathering solution to the 3D PTV, and the standard deviation of dose increased by 10%. However, 2D discrete Gaussian edge feathering with simulated eMLC leaf widths of 0.1-0.5 cm reduced the standard deviation of dose in the 3D PTV by 33-28%, respectively. Conclusions: A five-step discrete Gaussian edge

  5. Effect of Gold Nanoparticles on Prostate Dose Distribution under Ir-192 Internal and 18 MV External Radiotherapy Procedures Using Gel Dosimetry and Monte Carlo Method

    Directory of Open Access Journals (Sweden)

    Khosravi H.

    2015-03-01

    Full Text Available Background: Gel polymers are considered as new dosimeters for determining radiotherapy dose distribution in three dimensions. Objective: The ability of a new formulation of MAGIC-f polymer gel was assessed by experimental measurement and Monte Carlo (MC method for studying the effect of gold nanoparticles (GNPs in prostate dose distributions under the internal Ir-192 and external 18MV radiotherapy practices. Method: A Plexiglas phantom was made representing human pelvis. The GNP shaving 15 nm in diameter and 0.1 mM concentration were synthesized using chemical reduction method. Then, a new formulation of MAGIC-f gel was synthesized. The fabricated gel was poured in the tubes located at the prostate (with and without the GNPs and bladder locations of the phantom. The phantom was irradiated to an Ir-192 source and 18 MV beam of a Varian linac separately based on common radiotherapy procedures used for prostate cancer. After 24 hours, the irradiated gels were read using a Siemens 1.5 Tesla MRI scanner. The absolute doses at the reference points and isodose curves resulted from the experimental measurement of the gels and MC simulations following the internal and external radiotherapy practices were compared. Results: The mean absorbed doses measured with the gel in the presence of the GNPs in prostate were 15% and 8 % higher than the corresponding values without the GNPs under the internal and external radiation therapies, respectively. MC simulations also indicated a dose increase of 14 % and 7 % due to presence of the GNPs, for the same experimental internal and external radiotherapy practices, respectively. Conclusion: There was a good agreement between the dose enhancement factors (DEFs estimated with MC simulations and experiment gel measurements due to the GNPs. The results indicated that the polymer gel dosimetry method as developed and used in this study, can be recommended as a reliable method for investigating the DEF of GNPs in internal

  6. Polymer gel dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Baldock, C [Institute of Medical Physics, School of Physics, University of Sydney (Australia); De Deene, Y [Radiotherapy and Nuclear Medicine, Ghent University Hospital (Belgium); Doran, S [CRUK Clinical Magnetic Resonance Research Group, Institute of Cancer Research, Surrey (United Kingdom); Ibbott, G [Radiation Physics, UT M D Anderson Cancer Center, Houston, TX (United States); Jirasek, A [Department of Physics and Astronomy, University of Victoria, Victoria, BC (Canada); Lepage, M [Centre d' imagerie moleculaire de Sherbrooke, Departement de medecine nucleaire et de radiobiologie, Universite de Sherbrooke, Sherbrooke, QC (Canada); McAuley, K B [Department of Chemical Engineering, Queen' s University, Kingston, ON (Canada); Oldham, M [Department of Radiation Oncology, Duke University Medical Center, Durham, NC (United States); Schreiner, L J [Cancer Centre of South Eastern Ontario, Kingston, ON (Canada)], E-mail: c.baldock@physics.usyd.edu.au, E-mail: yves.dedeene@ugent.be

    2010-03-07

    Polymer gel dosimeters are fabricated from radiation sensitive chemicals which, upon irradiation, polymerize as a function of the absorbed radiation dose. These gel dosimeters, with the capacity to uniquely record the radiation dose distribution in three-dimensions (3D), have specific advantages when compared to one-dimensional dosimeters, such as ion chambers, and two-dimensional dosimeters, such as film. These advantages are particularly significant in dosimetry situations where steep dose gradients exist such as in intensity-modulated radiation therapy (IMRT) and stereotactic radiosurgery. Polymer gel dosimeters also have specific advantages for brachytherapy dosimetry. Potential dosimetry applications include those for low-energy x-rays, high-linear energy transfer (LET) and proton therapy, radionuclide and boron capture neutron therapy dosimetries. These 3D dosimeters are radiologically soft-tissue equivalent with properties that may be modified depending on the application. The 3D radiation dose distribution in polymer gel dosimeters may be imaged using magnetic resonance imaging (MRI), optical-computerized tomography (optical-CT), x-ray CT or ultrasound. The fundamental science underpinning polymer gel dosimetry is reviewed along with the various evaluation techniques. Clinical dosimetry applications of polymer gel dosimetry are also presented. (topical review)

  7. Stories of staying and leaving: A mixed methods analysis of biology undergraduate choice, persistence, and departure

    Science.gov (United States)

    Lang, Sarah Adrienne

    Using a sequential, explanatory mixed methods design, this dissertation study compared students who persist in the biology major (persisters) with students who leave the biology major (switchers) in terms of how their pre-college experiences, college biology experiences, and biology performance figured into their choice of biology and their persistence in or departure from the biology major. This study combined (1) quantitative comparisons of biology persisters and switchers via a questionnaire developed for the study and survival analysis of a larger population of biology freshmen with (2) qualitative comparison of biology switchers and persisters via semi-structured life story interviews and homogenous focus groups. 319 students (207 persisters and 112 switchers) participated in the questionnaire and 36 students (20 persisters and 16 switchers) participated in life story and focus group interviews. All participants were undergraduates who entered The University of Texas at Austin as biology freshmen in the fall semesters of 2000 through 2004. Findings of this study suggest: (1) Regardless of eventual major, biology students enter college with generally the same suite of experiences, sources of personal encouragement, and reasons for choosing the biology major; (2) Despite the fact that they have also had poor experiences in the major, biology persisters do not actively decide to stay in the biology major; they simply do not leave; (3) Based upon survival analysis, biology students are most at-risk of leaving the biology major during the first two years of college and if they are African-American or Latino, women, or seeking a Bachelor of Arts degree (rather than a Bachelor of Science); (4) Biology switchers do not leave biology due to preference for other disciplines; they leave due to difficulties or dissatisfaction with aspects of the biology major, including their courses, faculty, and peers; (5) Biology performance has a differential effect on persistence in

  8. Methods to Enrich Exosomes from Conditioned Media and Biological Fluids.

    Science.gov (United States)

    Sharma, Shayna; Scholz-Romero, Katherin; Rice, Gregory E; Salomon, Carlos

    2018-01-01

    Exosomes are nano-vesicles which can transport a range of molecules including but not limited to proteins and miRNA. This ability of exosomes renders them useful in cellular communication often resulting in biological changes. They have several functions in facilitating normal biological processes such as immune responses and an involvement in pregnancy. However, they have also been linked to pathological conditions including cancer and pregnancy complications such as preeclampsia. An understanding for the role of exosomes in preeclampsia is based on the ability to purify and characterize exosomes. There have been several techniques proposed for the enrichment of exosomes such as ultracentrifugation, density gradient separation, and ultrafiltration although there is no widely accepted optimized technique. Here we describe a workflow for isolating exosomes from cell-conditioned media and biological fluids using a combination of centrifugation, buoyant density, and ultrafiltration approaches.

  9. Theoretical basis for dosimetry

    International Nuclear Information System (INIS)

    Carlsson, G.A.

    1985-01-01

    Radiation dosimetry is fundamental to all fields of science dealing with radiation effects and is concerned with problems which are often intricate as hinted above. A firm scientific basis is needed to face increasing demands on accurate dosimetry. This chapter is an attempt to review and to elucidate the elements for such a basis. Quantities suitable for radiation dosimetry have been defined in the unique work to coordinate radiation terminology and usage by the International Commission on Radiation Units and Measurements, ICRU. Basic definitions and terminology used in this chapter conform with the recent ''Radiation Quantities and Units, Report 33'' of the ICRU

  10. Dosimetry for radiation processing

    International Nuclear Information System (INIS)

    Miller, Arne

    1986-01-01

    During the past few years significant advances have taken place in the different areas of dosimetry for radiation processing, mainly stimulated by the increased interest in radiation for food preservation, plastic processing and sterilization of medical products. Reference services both by international organizations (IAEA) and national laboratories have helped to improve the reliability of dose measurements. In this paper the special features of radiation processing dosimetry are discussed, several commonly used dosimeters are reviewed, and factors leading to traceable and reliable dosimetry are discussed. (author)

  11. SU-E-T-02: 90Y Microspheres Dosimetry Calculation with Voxel-S-Value Method: A Simple Use in the Clinic

    International Nuclear Information System (INIS)

    Maneru, F; Gracia, M; Gallardo, N; Olasolo, J; Fuentemilla, N; Bragado, L; Martin-Albina, M; Lozares, S; Pellejero, S; Miquelez, S; Rubio, A; Otal, A

    2015-01-01

    Purpose: To present a simple and feasible method of voxel-S-value (VSV) dosimetry calculation for daily clinical use in radioembolization (RE) with 90 Y microspheres. Dose distributions are obtained and visualized over CT images. Methods: Spatial dose distributions and dose in liver and tumor are calculated for RE patients treated with Sirtex Medical miscrospheres at our center. Data obtained from the previous simulation of treatment were the basis for calculations: Tc-99m maggregated albumin SPECT-CT study in a gammacamera (Infinia, General Electric Healthcare.). Attenuation correction and ordered-subsets expectation maximization (OSEM) algorithm were applied.For VSV calculations, both SPECT and CT were exported from the gammacamera workstation and registered with the radiotherapy treatment planning system (Eclipse, Varian Medical systems). Convolution of activity matrix and local dose deposition kernel (S values) was implemented with an in-house developed software based on Python code. The kernel was downloaded from www.medphys.it. Final dose distribution was evaluated with the free software Dicompyler. Results: Liver mean dose is consistent with Partition method calculations (accepted as a good standard). Tumor dose has not been evaluated due to the high dependence on its contouring. Small lesion size, hot spots in health tissue and blurred limits can affect a lot the dose distribution in tumors. Extra work includes: export and import of images and other dicom files, create and calculate a dummy plan of external radiotherapy, convolution calculation and evaluation of the dose distribution with dicompyler. Total time spent is less than 2 hours. Conclusion: VSV calculations do not require any extra appointment or any uncomfortable process for patient. The total process is short enough to carry it out the same day of simulation and to contribute to prescription decisions prior to treatment. Three-dimensional dose knowledge provides much more information than other

  12. SU-E-T-02: 90Y Microspheres Dosimetry Calculation with Voxel-S-Value Method: A Simple Use in the Clinic

    Energy Technology Data Exchange (ETDEWEB)

    Maneru, F; Gracia, M; Gallardo, N; Olasolo, J; Fuentemilla, N; Bragado, L; Martin-Albina, M; Lozares, S; Pellejero, S; Miquelez, S; Rubio, A [Complejo Hospitalario de Navarra, Pamplona, Navarra (Spain); Otal, A [Hospital Clinica Benidorm, Benidorm, Alicante (Spain)

    2015-06-15

    Purpose: To present a simple and feasible method of voxel-S-value (VSV) dosimetry calculation for daily clinical use in radioembolization (RE) with {sup 90}Y microspheres. Dose distributions are obtained and visualized over CT images. Methods: Spatial dose distributions and dose in liver and tumor are calculated for RE patients treated with Sirtex Medical miscrospheres at our center. Data obtained from the previous simulation of treatment were the basis for calculations: Tc-99m maggregated albumin SPECT-CT study in a gammacamera (Infinia, General Electric Healthcare.). Attenuation correction and ordered-subsets expectation maximization (OSEM) algorithm were applied.For VSV calculations, both SPECT and CT were exported from the gammacamera workstation and registered with the radiotherapy treatment planning system (Eclipse, Varian Medical systems). Convolution of activity matrix and local dose deposition kernel (S values) was implemented with an in-house developed software based on Python code. The kernel was downloaded from www.medphys.it. Final dose distribution was evaluated with the free software Dicompyler. Results: Liver mean dose is consistent with Partition method calculations (accepted as a good standard). Tumor dose has not been evaluated due to the high dependence on its contouring. Small lesion size, hot spots in health tissue and blurred limits can affect a lot the dose distribution in tumors. Extra work includes: export and import of images and other dicom files, create and calculate a dummy plan of external radiotherapy, convolution calculation and evaluation of the dose distribution with dicompyler. Total time spent is less than 2 hours. Conclusion: VSV calculations do not require any extra appointment or any uncomfortable process for patient. The total process is short enough to carry it out the same day of simulation and to contribute to prescription decisions prior to treatment. Three-dimensional dose knowledge provides much more information than

  13. Effect of Gold Nanoparticles on Prostate Dose Distribution under Ir-192 Internal and 18 MV External Radiotherapy Procedures Using Gel Dosimetry and Monte Carlo Method.

    Science.gov (United States)

    Khosravi, H; Hashemi, B; Mahdavi, S R; Hejazi, P

    2015-03-01

    Gel polymers are considered as new dosimeters for determining radiotherapy dose distribution in three dimensions. The ability of a new formulation of MAGIC-f polymer gel was assessed by experimental measurement and Monte Carlo (MC) method for studying the effect of gold nanoparticles (GNPs) in prostate dose distributions under the internal Ir-192 and external 18MV radiotherapy practices. A Plexiglas phantom was made representing human pelvis. The GNP shaving 15 nm in diameter and 0.1 mM concentration were synthesized using chemical reduction method. Then, a new formulation of MAGIC-f gel was synthesized. The fabricated gel was poured in the tubes located at the prostate (with and without the GNPs) and bladder locations of the phantom. The phantom was irradiated to an Ir-192 source and 18 MV beam of a Varian linac separately based on common radiotherapy procedures used for prostate cancer. After 24 hours, the irradiated gels were read using a Siemens 1.5 Tesla MRI scanner. The absolute doses at the reference points and isodose curves resulted from the experimental measurement of the gels and MC simulations following the internal and external radiotherapy practices were compared. The mean absorbed doses measured with the gel in the presence of the GNPs in prostate were 15% and 8 % higher than the corresponding values without the GNPs under the internal and external radiation therapies, respectively. MC simulations also indicated a dose increase of 14 % and 7 % due to presence of the GNPs, for the same experimental internal and external radiotherapy practices, respectively. There was a good agreement between the dose enhancement factors (DEFs) estimated with MC simulations and experiment gel measurements due to the GNPs. The results indicated that the polymer gel dosimetry method as developed and used in this study, can be recommended as a reliable method for investigating the DEF of GNPs in internal and external radiotherapy practices.

  14. Using the Scientific Method to Motivate Biology Students to Study Precalculus

    Science.gov (United States)

    Fulton, James P.; Sabatino, Linda

    2008-01-01

    During the last two years we have developed a precalculus course customized around biology by using the scientific method as a framework to engage and motivate biology students. Historically, the precalculus and calculus courses required for the Suffolk County Community College biology curriculum were designed using examples from the physical…

  15. Quantum mechanical simulation methods for studying biological systems

    International Nuclear Information System (INIS)

    Bicout, D.; Field, M.

    1996-01-01

    Most known biological mechanisms can be explained using fundamental laws of physics and chemistry and a full understanding of biological processes requires a multidisciplinary approach in which all the tools of biology, chemistry and physics are employed. An area of research becoming increasingly important is the theoretical study of biological macromolecules where numerical experimentation plays a double role of establishing a link between theoretical models and predictions and allowing a quantitative comparison between experiments and models. This workshop brought researchers working on different aspects of the development and application of quantum mechanical simulation together, assessed the state-of-the-art in the field and highlighted directions for future research. Fourteen lectures (theoretical courses and specialized seminars) deal with following themes: 1) quantum mechanical calculations of large systems, 2) ab initio molecular dynamics where the calculation of the wavefunction and hence the energy and forces on the atoms for a system at a single nuclear configuration are combined with classical molecular dynamics algorithms in order to perform simulations which use a quantum mechanical potential energy surface, 3) quantum dynamical simulations, electron and proton transfer processes in proteins and in solutions and finally, 4) free seminars that helped to enlarge the scope of the workshop. (N.T.)

  16. Biological stability of drinking water : Controlling factors, methods, and challenges

    NARCIS (Netherlands)

    Prest, E.I.E.D.; Hammes, F.; Van Loosdrecht, M.C.M.; Vrouwenvelder, J.S.

    2016-01-01

    Biological stability of drinking water refers to the concept of providing consumers with drinking water of same microbial quality at the tap as produced at the water treatment facility. However, uncontrolled growth of bacteria can occur during distribution in water mains and premise plumbing, and

  17. Method of inactivating reproducible forms of mycoplasma in biological preparations

    International Nuclear Information System (INIS)

    Veber, P.; Jurmanova, K.; Lesko, J.; Hana, L.; Veber, V.

    1978-01-01

    Inactivation of mycoplasms in biological materials was achieved using gamma radiation with a dose rate of 1x10 4 to 5x10 6 rads/h for 1 to 250 hours. The technique is advantageous for allowing the inactivation of the final form of products (tablets, vaccines, etc.). (J.P.)

  18. Thin film composition with biological substance and method of making

    International Nuclear Information System (INIS)

    Campbell, A.A.; Song, L.

    1999-01-01

    The invention provides a thin-film composition comprising an underlying substrate of a first material including a plurality of attachment sites; a plurality of functional groups chemically attached to the attachment sites of the underlying substrate; and a thin film of a second material deposited onto the attachment sites of the underlying substrate, and a biologically active substance deposited with the thin-film. Preferably the functional groups are attached to a self assembling monolayer attached to the underlying substrate. Preferred functional groups attached to the underlying substrate are chosen from the group consisting of carboxylates, sulfonates, phosphates, optionally substituted, linear or cyclo, alkyl, alkene, alkyne, aryl, alkylaryl, amine, hydroxyl, thiol, silyl, phosphoryl, cyano, metallocenyl, carbonyl, and polyphosphate. Preferred materials for the underlying substrate are selected from the group consisting of a metal, a metal alloy, a plastic, a polymer, a proteic film, a membrane, a glass or a ceramic. The second material is selected from the group consisting of inorganic crystalline structures, inorganic amorphous structures, organic crystalline structures, and organic amorphous structures. Preferred second materials are phosphates, especially calcium phosphates and most particularly calcium apatite. The biologically active molecule is a protein, peptide, DNA segment, RNA segment, nucleotide, polynucleotide, nucleoside, antibiotic, antimicrobial, radioisotope, chelated radioisotope, chelated metal, metal salt, anti-inflammatory, steroid, nonsteroid anti-inflammatory, analgesic