WorldWideScience

Sample records for bioabsorbable staple line

  1. Buttressing staples with cholecyst-derived extracellular matrix (CEM) reinforces staple lines in an ex vivo peristaltic inflation model.

    LENUS (Irish Health Repository)

    Burugapalli, Krishna

    2008-11-01

    Staple line leakage and bleeding are the most common problems associated with the use of surgical staplers for gastrointestinal resection and anastomotic procedures. These complications can be reduced by reinforcing the staple lines with buttressing materials. The current study reports the potential use of cholecyst-derived extracellular matrix (CEM) in non-crosslinked (NCEM) and crosslinked (XCEM) forms, and compares their mechanical performance with clinically available buttress materials [small intestinal submucosa (SIS) and bovine pericardium (BP)] in an ex vivo small intestine model.

  2. A Randomized Comparison Between Staple-Line Oversewing Versus No Reinforcement During Laparoscopic Vertical Sleeve Gastrectomy.

    Science.gov (United States)

    Taha, Osama; Abdelaal, Mahmoud; Talaat, Mohamed; Abozeid, Mohamed

    2018-01-01

    Varieties of intraoperative methods such as oversewing of staple lines or other reinforcement products are used for preventing the laparoscopic vertical sleeve gastrectomy (LSG) complications. The aim of this study is to evaluate the complication rates of the gastric stapling alone versus stapling with oversewing invagination of the staple line in the LSG. This is a single-center randomized study, Patients were randomized to two groups, 200 patients underwent LSG without reinforcement of the staple line and 200 patients underwent LSG with oversewing of the staple line. All patients were followed up for 1 year. The data collected prospectively for statistical analysis included demographics, BMI, preoperative comorbidities, operative time, complications, and hospital stay. The overall mean operative age was 33.7 ± 9.4 years and mean BMI was 42.4 ± 4.3 kg/m 2 . Patient baseline characteristics (age, gender, weight, and BMI) and comorbidities were generally a nonsignificant different between the treatment arms. Surgical time was shorter in patients of the nonreinforced group (44.3 ± vs 51.3 ± 4.3 min; p < 0.01) with lower %EWL (73 ± 13.8 vs 80.7 ± 13.6%, p < 0.01). One patient in the nonreinforced group was complicated by gastric leak. The staple-line bleeding rate was significantly lower in patients underwent oversewing of the staple line during LSG (p < 0.05). Oversewing of the staple line during LSG is a nonexpansive and easy method to decrease the incidence and severity of the postoperative bleeding. However, it is time-consuming and should be performed by experienced surgeons to avoid the complications which may occur secondary to the seroserotomy suturing.

  3. Research of a novel biodegradable surgical staple made of high purity magnesium

    Directory of Open Access Journals (Sweden)

    Hongliu Wu

    2016-12-01

    Full Text Available Surgical staples made of pure titanium and titanium alloys are widely used in gastrointestinal anastomosis. However the Ti staple cannot be absorbed in human body and produce artifacts on computed tomography (CT and other imaging examination, and cause the risk of incorrect diagnosis. The bioabsorbable staple made from polymers that can degrade in human body environment, is an alternative. In the present study, biodegradable high purity magnesium staples were developed for gastric anastomosis. U-shape staples with two different interior angles, namely original 90° and modified 100°, were designed. Finite element analysis (FEA showed that the residual stress concentrated on the arc part when the original staple was closed to B-shape, while it concentrated on the feet for the modified staple after closure. The in vitro tests indicated that the arc part of the original staple ruptured firstly after 7 days immersion, whereas the modified one kept intact, demonstrating residual stress greatly affected the corrosion behavior of the HP-Mg staples. The in vivo implantation showed good biocompatibility of the modified Mg staples, without inflammatory reaction 9 weeks post-operation. The Mg staples kept good closure to the Anastomosis, no leaking and bleeding were found, and the staples exhibited no fracture or severe corrosion cracks during the degradation.

  4. Staple Line Reinforcement with Stitch in Laparoscopic Sleeve Gastrectomies. Is It Useful or Harmful?

    Science.gov (United States)

    Albanopoulos, Konstantinos; Tsamis, Dimitrios; Arapaki, Aggeliki; Kleidi, Eleftheria; Zografos, Georgios; Leandros, Emmanouil

    2015-07-01

    Reinforcement of the staple line in laparoscopic sleeve gastrectomy (LSG) is a practice that leads to less morbidity, but equivocal results have been reported in the literature. This is a prospective randomized study comparing two groups of patients who underwent LSG. In one group LSG was performed with a running absorbable suture placement at the staple line. In the other group the running suture was not placed. General data of the patients, as well as intraoperative and postoperative data, were gathered and statistically analyzed. Overall, 146 patients were subjected to LSG. In 84 patients a running suture was placed, and in 62 patients no suture was placed. No significant differences were found between the two groups in demographic data. No significant differences were found also in the intraoperative data, such as number of trocars, number and type of cartridges, drain placement, and operative time (45±21 versus 40±20 minutes, respectively; Prunning suture (9.5% versus 0.0%, respectively; P.05). After this randomized study, final conclusions about the efficacy of this running suture to the staple line cannot be made. To the contrary, problems seem to exist after such reinforcement of the staple line, such as hematomas. Dealing with possible leaks and hemorrhage of the staple line is also problematic after placement of the running suture.

  5. Staple line reinforcement with fleece-coated fibrin glue (TachoComb) after thoracoscopic bullectomy for the treatment of spontaneous pneumothorax

    International Nuclear Information System (INIS)

    Muramatsu, Takashi; Ohmori, Kazumitsu; Shimamura, Mie; Furuichi, Motohiko; Takeshita, Shinji; Negishi, Nanao

    2007-01-01

    We investigated the cause of pneumothorax recurrence after thoracoscopic surgery and the effectiveness of staple line reinforcement with fleece-coated fibrin glue (TachoComb) in the prevention of postoperative pneumothorax recurrence. From April 3, 1992 to the end of December 2005, thoracoscopic bullectomy was performed on 499 patients of primary spontaneous pneumothorax. The causes of recurrence were investigated on 39 patients on the basis of surgical observations, preoperative chest computed tomography, and so on. The most common cause was new bulla formation (37 cases), 19 of which were apparently related to the staple line (within 1 cm of the staple lines) and 15 of which were not related to the staple line. After 2000, we stopped using forceps to grasp lungs and we have reinforced the staple line by applying fleece-coated fibrin glue. The staple line reinforced with fleece-coated fibrin glue, or sprayed with fibrin glue solution and the untreated group (bullectomy only with staples) were compared, and the recurrence rates were 1.22%, 7.25%, and 10.00%, respectively (P=0.0006021). The recurrence rate after thoracoscopic bullectomy with fleece-coated fibrin glue was significantly lowered and we consider this procedure to be the treatment of choice for the management of spontaneous pneumothorax. (author)

  6. Use of a mattress suture to eliminate dog ears in double-stapled and triple-stapled anastomoses.

    Science.gov (United States)

    Asao, Takayuki; Kuwano, Hiroyuki; Nakamura, Jun-ichi; Hirayama, Isao; Ide, Munenori; Moringa, Nobuhiro; Fujita, Kin-ichi

    2002-01-01

    Double-stapling techniques for restorative rectal resection have been effective in minimizing local contamination compared with open circular stapling techniques. Inclusion of the transverse staple line closure of the distal rectal stump in the circular stapled anastomosis may minimize the risk of suture line recurrence. A technique for formation of such an anastomosis is described that avoids use of a distal purse string.

  7. Staple line leak with peritonitis after laparoscopic sleeve gastrectomy - a solution in one to six steps.

    Science.gov (United States)

    Špička, Petr

    2017-06-01

    Laparoscopic sleeve gastrectomy (LSG) is one of the most efficient bariatric interventions in morbidly obese patients. The most severe risk of this procedure seems to be the staple line leak, and the management of this complication can be very arduous. To share our experience in managing the staple line leak after LSG and to help to find the best procedure that should be preferred. In the 2010-2015 period we performed 223 LSG, with about 5 demonstrating severe complications - two patients with severe bleeding requiring revision surgery, and three patients with resection surface leak. We always primarily treated the staple line leak with a laparoscopic revision. Once the fistula did not spontaneously close after this treatment. A series of other methods were then indicated for this patient and only the sixth one resulted in the desirable therapeutic success. At first, our team opted for laparoscopic revision with drainage. The next procedure involved applying Ovesco and Boston clips. As a third method we performed abscess drainage through a nasobiliary tube inserted via gastroscopy. Due to failure we performed the second laparoscopic revision with staple line resuture, the next intervention was an open revision with fistula excision and suture, and finally we opted for the application of a self-expanding metallic stent, which proved to be definitely curative. Without any guidelines it is very difficult to determine the right procedure addressing the staple line leak after LSG. It depends mainly on the clinician's experience and is lengthy and often untraditional.

  8. [NITINOL shape memory staple for osteosynthesis of the scaphoid].

    Science.gov (United States)

    Winkel, Reiner; Schlageter, Michael

    2009-11-01

    Reconstruction of the scaphoid with use of NITINOL shape "memory" staples. Unstable fractures and nonunion of the middle third of the scaphoid, which need open reduction and internal fixation from palmar. The staples can only be used, if the arms of the staples can be inserted parallel to and at a distance of 3 mm to the fracture line. Allergy to nickel. Cases in which the arms of the staple cannot be inserted parallel to and at best 3 mm apart from the fracture line. In fractures, open reduction of the scaphoid through a palmar approach. If necessary, interposition of a bone graft and Kirschner wire transfixation. Drilling of the drill holes parallel and at a distance of 3 mm to the fracture line. Insertion of the NITINOL staple. In nonunion, excision of the fibrous nonunion, refreshening of the fracture surfaces, interposition of a bone graft and, if needed, fixation with a Kirschner wire. Drilling of the drill holes for the NITINOL staple and insertion of the staple. Within a few minutes the warming-up staple contracts and thereby compresses the scaphoid. Immobilization in a short cast with thumb support for 6 weeks. Control for bone healing by radiographs or computed tomography. Staples, which do not cause hardware problems, are not removed. Kirschner wires are removed after bone healing. From October 1995 to December 2006, the authors used NITINOL staples for 65 osteosyntheses of the scaphoid. Indications were 15 unstable fractures, 47 nonunions, and three partial necroses. 61 out of 65 scaphoids healed without further surgery, three of the 61 patients showed a delayed healing. Two of the four nonunions were related to the use of the NITINOL staples. Seven staples were removed, one for loosening. NITINOL shape memory staples have proven to be very helpful for osteosynthesis in fractures and nonunion of the scaphoid, if the prerequisites are given for their use.

  9. Are bio-absorbable stents the future of SFA treatment?

    Science.gov (United States)

    Peeters, P; Keirse, K; Verbist, J; Deloose, K; Bosiers, M

    2010-02-01

    Several limitations inherent to the implantation of a metallic device, such as the occurrence of in-stent re-stenosis, in an arterial lumen intuitively explain the interest for developing bio-absorbable stents. Two main types of bio-absorbable stents currently exist: polymer stents and metallic stents. To date, no studies with bio-absorbable stents have been conducted in the superficial femoral artery (SFA). Because of their strut thickness and lack of radial force, polymer stents are no good candidates for endovascular use. Absorbable metal stents (AMS) do have the potential to perform well for artery treatment, although current evidence from in-human coronary and infrapopliteal studies yield unsatisfactory results. Drastic technological improvements are mandatory before AMS can be considered for every day practice. Yet, it is our belief that further development of other metal and non-metal bio-absorbable stents, with or without drug-coating, may lead to the creation of the ultimate SFA stent.

  10. How I do it: the stapled ileal J pouch at restorative proctocolectomy.

    LENUS (Irish Health Repository)

    Martin, S T

    2011-12-01

    Ileal pouch-anal anastomosis (IPAA) following proctocolectomy is the preferred option for patients with medically refractory ulcerative colitis, indeterminate colitis, and familial adenomatous polyposis. However, it remains a procedure associated with morbidity and mortality. Pelvic sepsis, pouch fistulae, and anastomotic dehiscence predispose to pouch failure. We report our experience with an adaptation for the formation of the stapled ileal J pouch using the GIA™ 100 stapling device (Covidien, Mansfield, Massachusetts, USA). When creating the J pouch, we remove the bevelled plastic protector from the thin fork of the stapling device, allowing the staple line to be completed to the tip of the stapled efferent limb of the pouch, thereby minimizing potential blind ending in the efferent limb and injury to the transverse staple line.

  11. Next generation drug-eluting stents: focus on bioabsorbable platforms and polymers

    Directory of Open Access Journals (Sweden)

    Brendan Doyle

    2009-11-01

    Full Text Available Brendan Doyle, David R Holmes JrDivision of Cardiovascular Diseases, Department of Internal Medicine, Mayo Clinic College of Medicine, Rochester, Minnesota, USAAbstract: The success of drug-eluting stents in preventing restenosis has shifted the focus of new stent development toward enhancing long term safety and efficacy of these devices, while simultaneously eliminating the need for indefinite dual antiplatelet therapy. A technical advance fulfilling these aims would hold tremendous potential to reduce morbidity, mortality and economic costs associated with the percutaneous treatment of coronary artery disease. An attractive approach is the use of bioabsorbable stent designs. These may include stents with different bioabsorbable drugs, bioabsorbable polymers or even bioabsorbable metallic backbones. A device that could achieve excellent acute and long-term results, but disappear completely within months (thereby avoiding the need for prolonged dual antiplatelet therapy, would be a tremendous advance. Too good to be true? We explore here the scientific rationale and prospects for success with this exciting concept.Keywords: percutaneous coronary intervention, biodegradable, bioabsorbable, polymer, stent

  12. Materials and Manufacturing Technologies Available for Production of a Pediatric Bioabsorbable Stent

    Science.gov (United States)

    Alexy, Ryan D.; Levi, Daniel S.

    2013-01-01

    Transcatheter treatment of children with congenital heart disease such as coarctation of the aorta and pulmonary artery stenosis currently involves the use of metal stents. While these provide good short term results, there are long term complications with their use. Children outgrow metal stents, obligating them to future transcatheter dilations and eventual surgical removal. A bioabsorbable stent, or a stent that goes away with time, would solve this problem. Bioabsorbable stents are being developed for use in coronary arteries, however these are too small for use in pediatric congenital heart disease. A bioabsorbable stent for use in pediatric congenital heart disease needs to be low profile, expandable to a diameter 8 mm, provide sufficient radial strength, and absorb quickly enough to allow vessel growth. Development of absorbable coronary stents has led to a great understanding of the available production techniques and materials such as bioabsorbable polymers and biocorrodable metals. Children with congenital heart disease will hopefully soon benefit from the current generation of bioabsorbable and biocorrodable materials and devices. PMID:24089660

  13. Materials and Manufacturing Technologies Available for Production of a Pediatric Bioabsorbable Stent

    Directory of Open Access Journals (Sweden)

    Ryan D. Alexy

    2013-01-01

    Full Text Available Transcatheter treatment of children with congenital heart disease such as coarctation of the aorta and pulmonary artery stenosis currently involves the use of metal stents. While these provide good short term results, there are long term complications with their use. Children outgrow metal stents, obligating them to future transcatheter dilations and eventual surgical removal. A bioabsorbable stent, or a stent that goes away with time, would solve this problem. Bioabsorbable stents are being developed for use in coronary arteries, however these are too small for use in pediatric congenital heart disease. A bioabsorbable stent for use in pediatric congenital heart disease needs to be low profile, expandable to a diameter 8 mm, provide sufficient radial strength, and absorb quickly enough to allow vessel growth. Development of absorbable coronary stents has led to a great understanding of the available production techniques and materials such as bioabsorbable polymers and biocorrodable metals. Children with congenital heart disease will hopefully soon benefit from the current generation of bioabsorbable and biocorrodable materials and devices.

  14. Staple Line Reinforcement During Laparoscopic Sleeve Gastrectomy: Absorbable Monofilament, Barbed Suture, Fibrin Glue, or Nothing? Results of a Prospective Randomized Study.

    Science.gov (United States)

    Carandina, S; Tabbara, M; Bossi, M; Valenti, A; Polliand, C; Genser, L; Barrat, Christophe

    2016-02-01

    Laparoscopic sleeve gastrectomy (LSG) is associated with serious complications, such as staple line (SL) leaks and bleeding. In order to prevent the occurrence of these complications, surgeons have advocated the need to strengthen the staple line. The aim of this randomized controlled study was to compare the efficacy of three different ways of strengthening of the SL in LSG in preventing surgical post-operative complications. Between April 2012 and December 2014, 600 patients (pts) scheduled for LSG were prospectively randomized into groups without SL reinforcement (group A) or with SL reinforcement including fibrin glue coverage (group B), or oversewn SL with imbricating absorbable (Monocryl™; group C) or barbed (V lock®) running suture (group D). Primary endpoints were post-operative leaks, bleeding, and stenosis, while secondary outcomes consisted of the time to perform the staple line reinforcement (SLR) and total operative time. Mean SLR operative time was lower for group B (3.4 ± 1.3 min) compared with that for groups C (26.8 ± 8.5 min) and D (21.1 ± 8.4 min) (p running suture or with fibrin glue, is an unrewarding surgical act with the sole effect of prolonging the operative time.

  15. Effect of the bio-absorbent on the microwave absorption property of the flaky CIPs/rubber absorbers

    Energy Technology Data Exchange (ETDEWEB)

    Cheng, Yang; Xu, Yonggang, E-mail: xuyonggang221@163.com; Cai, Jun; Yuan, Liming; Zhang, Deyuan

    2015-09-01

    Microwave absorbing composites filled with flaky carbonyl iron particles (CIPs) and the bio-absorbent were prepared by using a two-roll mixer and a vulcanizing machine. The electromagnetic (EM) parameters were measured by a vector network analyzer and the reflection loss (RL) was measured by the arch method in the frequency range of 1–4 GHz. The uniform dispersion of the absorbents was verified by comparing the calculated RL with the measured one. The results confirm that as the bio-absorbent was added, the permittivity was increased due to the volume content of absorbents, and the permeability was enlarged owing to the volume content of CIPs and interactions between the two absorbents. The composite filled with bio-absorbents achieved an excellent absorption property at a thickness of 1 mm (minimum RL reaches −7.8 dB), and as the RL was less than −10 dB the absorption band was widest (2.1–3.8 GHz) at a thickness of 2 mm. Therefore, the bio-absorbent is a promising additive candidate on fabricating microwave absorbing composites with a thinner thickness and wider absorption band. - Graphical abstract: Morphology of composites filled with flaky CIPs and the bio-absorbent. The enhancement of bio-absorbent on the electromagnetic absorption property of composites filled with flaky carbonyl iron particles (CIPs) is attributed to the interaction of the two absorbents. The volume content of the FCMPs with the larger shape CIPs play an important role in this effects, the composites filled with irons and bio-absorbents can achieve wider-band and thinner-thickness absorbing materials. - Highlights: • Absorbers filled with bio-absorbents and CIPs was fabricated. • Bio-absorbents enhanced the permittivity and permeability of the composites. • The absorbent interactions play a key role in the enhancement mechanism. • Bio-absorbents enhanced the composite RL in 1–4 GHz.

  16. Mechanical design optimization of bioabsorbable fixation devices for bone fractures.

    Science.gov (United States)

    Lovald, Scott T; Khraishi, Tariq; Wagner, Jon; Baack, Bret

    2009-03-01

    Bioabsorbable bone plates can eliminate the necessity for a permanent implant when used to fixate fractures of the human mandible. They are currently not in widespread use because of the low strength of the materials and the requisite large volume of the resulting bone plate. The aim of the current study was to discover a minimally invasive bioabsorbable bone plate design that can provide the same mechanical stability as a standard titanium bone plate. A finite element model of a mandible with a fracture in the body region is subjected to bite loads that are common to patients postsurgery. The model is used first to determine benchmark stress and strain values for a titanium plate. These values are then set as the limits within which the bioabsorbable bone plate must comply. The model is then modified to consider a bone plate made of the polymer poly-L/DL-lactide 70/30. An optimization routine is run to determine the smallest volume of bioabsorbable bone plate that can perform and a titanium bone plate when fixating fractures of this considered type. Two design parameters are varied for the bone plate design during the optimization analysis. The analysis determined that a strut style poly-L-lactide-co-DL-lactide plate of 690 mm2 can provide as much mechanical stability as a similar titanium design structure of 172 mm2. The model has determined a bioabsorbable bone plate design that is as strong as a titanium plate when fixating fractures of the load-bearing mandible. This is an intriguing outcome, considering that the polymer material has only 6% of the stiffness of titanium.

  17. Gastric wall thickness and stapling in laparoscopic sleeve gastrectomy - a literature review.

    Science.gov (United States)

    Barski, Krzysztof; Binda, Artur; Kudlicka, Emilia; Jaworski, Paweł; Tarnowski, Wiesław

    2018-03-01

    Despite the growing experience of bariatric surgeons in performing laparoscopic sleeve gastrectomy, the number of complications involving staple line leaks remains constant. Hence a solution to avoid such complications is still sought. A defect of the staple line may be the consequence of an inappropriate choice of staple size in relation to gastric wall thickness. Due to the variable nature of gastric wall thickness, the choice of proper staple height is not obvious. In the few studies in which gastric wall thickness was measured, it was observed to decrease gradually from the antrum to the fundus. However, the authors are divided on the issue of whether gender and body mass index influence gastric wall thickness. The question whether there are other perioperative factors that would allow gastric wall thickness to be predicted remains unanswered.

  18. Delayed Foreign Body Reaction Caused by Bioabsorbable Plates Used for Maxillofacial Fractures

    Directory of Open Access Journals (Sweden)

    Hong Bae Jeon

    2016-01-01

    Full Text Available BackgroundBioabsorbable plates and screws are commonly used to reduce maxillofacial bones, particularly in pediatric patients because they degrade completely without complications after bone healing. In this study, we encountered eight cases of a delayed foreign body reaction after surgical fixation with bioabsorbable plates and screws.MethodsA total of 234 patients with a maxillofacial fracture underwent surgical treatment from March 2006 to October 2013, in which rigid fixation was achieved with the Inion CPS (Inion, Tampere, Finland plating system in 173 patients and Rapidsorb (Synthes, West Chester, PA, USA in 61 patients. Their mean age was 35.2 years (range, 15-84 years. Most patients were stabilized with two- or three-point fixation at the frontozygomatic suture, infraorbital rim, and anterior wall of the maxilla.ResultsComplications occurred in eight (3.4% of 234 patients, including palpable, fixed masses in six patients and focal swelling in two patients. The period from surgical fixation to the onset of symptoms was 9-23 months. Six patients with a mass underwent secondary surgery for mass removal. The masses contained fibrous tissue with a yellow, grainy, cloudy fluid and remnants of an incompletely degraded bioabsorbable plate and screws. Their histological findings demonstrated a foreign body reaction.ConclusionsInadequate degradation of bioabsorbable plates caused a delayed inflammatory foreign body reaction requiring secondary surgery. Therefore, it is prudent to consider the possibility of delayed complications when using bioabsorbable plates and surgeons must conduct longer and closer follow-up observations.

  19. Bioabsorbable metal screws in traumatology: A promising innovation

    Directory of Open Access Journals (Sweden)

    Roland Biber

    2017-04-01

    Full Text Available MAGNEZIX® CS (Syntellix AG, Hanover, Germany is a bioabsorbable compression screw made of a magnesium alloy (MgYREZr. Currently there are only two clinical studies reporting on a limited number of elective patients who received this screw in a hallux valgus operation. We applied MAGNEZIX® CS for fixation of distal fibular fracture in a trauma patient who had sustained a bimalleolar fracture type AO 44-B2.3. Clinical course was uneventful, fracture healing occurred within three months. Follow-up X-rays showed a radiolucent area around the implant for some months, yet this radiolucent area had disappeared in the 17-months follow-up X-ray. Keywords: Magnesium, Bioabsorbable, Compression screw, Osteosynthesis, Ankle fracture

  20. Are there risk factors that increase the rate of staple line leakage in patients undergoing primary sleeve gastrectomy for morbid obesity?

    Science.gov (United States)

    Benedix, Frank; Benedix, Diana D; Knoll, Christian; Weiner, Rudolf; Bruns, Christiane; Manger, Thomas; Stroh, Christine

    2014-10-01

    Laparoscopic sleeve gastrectomy (LSG) is currently being performed with increasing frequency worldwide. It offers an excellent weight loss and resolution of comorbidities in the short term with a very low incidence of complications. However, the ever present risk of a staple line leak is still a major concern. Since 2005, data from obese patients that undergo bariatric procedures in Germany are prospectively registered in an online database and analyzed at the Institute of Quality Assurance in Surgical Medicine. For the current analysis, all patients that had undergone primary sleeve gastrectomy for morbid obesity within a 7-year period were considered. Using the GBSR, data from 5.400 LSGs were considered for analysis. Staple line leak rate decreased during the study period from 6.5 to 1.4 %. Male gender, higher BMI, concomitant sleep apnea, conversion to laparotomy, longer operation time, use of both buttresses and oversewing, and the occurrence of intraoperative complications were associated with a significantly higher leakage rate. On multivariate analysis, operation time and year of procedure only had a significant impact on staple line leak rate. The results of the current study demonstrated that there are factors that increase the risk of a leakage which would enable surgeons to define risk groups, to more carefully select patients, and to offer a closer follow-up during the postoperative course with early recognition and adequate treatment. All future efforts should be focused on a further reduction of serious complications to make the LSG a widely accepted and safer procedure.

  1. Bioabsorbable coronary stents--are these the next big thing in coronary angioplasty?

    Science.gov (United States)

    Balla, Sudarshan; Aggarwal, Kul; Nistala, Ravi

    2010-06-01

    The role of percutaneous coronary intervention (PCI) in the treatment of coronary artery disease has grown at an astronomical pace. Drug eluting stents (DES) offer advantages over bare metal stents (BMS) such as reduction in early in-stent restenosis rates. However, they have disadvantages like from increased late stent thrombosis when compared with BMS. Furthermore, recent data suggest endothelial dysfunction in the DES stented segments of the arteries. Currently, bioabsorbable stents are under development to avert the complications of DES such as stent thrombosis via degradation of the stent over time. The hypothetical advantage of leaving behind a natural vessel and restoring vasoreactivity may be the almost normal physiology which can be achieved after an intervention with a stent. The ABSORB and the PROGRESS AMS are two of the recent clinical trials that have looked at the outcomes of using bioabsorbable stents. So far, data from these and other studies has yielded mixed results in terms of angiographic and clinical outcomes. Newer stents such as REVA and WHISPER are presently being tested in preclinical and clinical trials. The landscape for bioabsorbable stents is constantly evolving through continued improvisation on existing technology and emergence of new technology. Large scale randomized trials are still needed with adequate long term follow-up for safety and benefits to have mainstream application in coronary artery disease, bioabsorbable stents are a promising innovation in the field of PCI. We review some of the patents and the data that is emerging on bioabsorbable stents in addition to currently ongoing clinical trials.

  2. Diversity-oriented peptide stapling

    DEFF Research Database (Denmark)

    Tran, Thu Phuong; Larsen, Christian Ørnbøl; Røndbjerg, Tobias

    2017-01-01

    as a powerful method for peptide stapling. However, to date CuAAC stapling has not provided a simple method for obtaining peptides that are easily diversified further. In the present study, we report a new diversity-oriented peptide stapling (DOPS) methodology based on CuAAC chemistry. Stapling of peptides...

  3. Comparison of Suture-Based Anchors and Traditional Bioabsorbable Anchors in Foot and Ankle Surgery.

    Science.gov (United States)

    Hembree, W Chad; Tsai, Michael A; Parks, Brent G; Miller, Stuart D

    We compared the pullout strength of a suture-based anchor versus a bioabsorbable anchor in the distal fibula and calcaneus and evaluated the relationship between bone mineral density and peak load to failure. Eight paired cadaveric specimens underwent a modified Broström procedure and Achilles tendon reattachment. The fibula and calcaneus in the paired specimens received either a suture-based anchor or a bioabsorbable suture anchor. The fibular and calcaneal specimens were loaded to failure, defined as a substantial decrease in the applied load or pullout from the bone. In the fibula, the peak load to failure was significantly greater with the suture-based versus the bioabsorbable anchors (133.3 ± 41.8 N versus 76.8 ± 35.3 N; p = .002). No significant difference in load with 5 mm of displacement was found between the 2 groups. In the calcaneus, no difference in the peak load to failure was found between the 2 groups, and the peak load to failure with 5 mm of displacement was significantly lower with the suture-based than with the bioabsorbable anchors (52.2 ± 9.8 N versus 75.9 ± 12.4 N; p = .003). Bone mineral density and peak load to failure were significantly correlated in the fibula with the suture-based anchor. An innovative suture-based anchor had a greater peak load to failure compared with a bioabsorbable anchor in the fibula. In the calcaneus, the load at 5 mm of displacement was significantly lower in the suture-based than in the bioabsorbable group. The correlation findings might indicate the need for a cortical bone shelf with the suture-based anchor. Suture-based anchors could be a viable alternative to bioabsorbable anchors for certain foot and ankle procedures. Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  4. C-reactive protein, fibrinogen, and procalcitonin levels as early markers of staple line leak after laparoscopic sleeve gastrectomy in morbidly obese patients within an Enhanced Recovery After Surgery (ERAS) program.

    Science.gov (United States)

    Ruiz-Tovar, Jaime; Muñoz, Jose Luis; Gonzalez, Juan; Garcia, Alejandro; Ferrigni, Carlos; Jimenez, Montiel; Duran, Manuel

    2017-12-01

    The performance of most bariatric procedures within an Enhanced Recovery After Surgery program has resulted in significant advantages, including a reduction in the length of hospital stay to 2-3 days. However, some postoperative complications may appear after the patient has been discharged. The aim of this study was to investigate the efficacy of various acute-phase parameters determined 24 h after a laparoscopic sleeve gastrectomy for predicting staple line leak in the postoperative course. A prospective study of 208 morbidly obese patients undergoing laparoscopic sleeve gastrectomy as bariatric procedure between 2012 and 2015 was performed. Blood analysis was performed 24 h after surgery. Acute-phase parameters (C-reactive protein, procalcitonin, fibrinogen, and White Blood Cell count) were investigated. Staple line leak appeared in eight patients (3.8%). Using receiver operating characteristic analysis at 24 h postoperatively, a cutoff level of CRP at 9 mg/dL achieved 85% sensitivity and 90% specificity for predicting staple line leak, a cutoff level of procalcitonin at 0.85 ng/mL achieved 70% sensitivity and 90% specificity, and a cutoff level of fibrinogen at 600 mg/dL achieved 80% sensitivity and 87.5% specificity. An elevation of CRP > 9 mg/dL, procalcitonin > 0.85 ng/mL and fibrinogen > 600 mg/dL should alert the surgeon the possibility of occurrence of postoperative staple line leak.

  5. Bioabsorbable Suture Anchor Migration to the Acromioclavicular Joint: How Far Can These Implants Go?

    Directory of Open Access Journals (Sweden)

    Giovanna Medina

    2014-01-01

    Full Text Available Few complications regarding the use of bioabsorbable suture anchors in the shoulder have been reported. What motivated this case report was the unusual location of the anchor, found in the acromioclavicular joint which, to our knowledge, has never been reported so far. A 53-year old male with previous rotator cuff (RC repair using bioabsorbable suture anchors presented with pain and weakness after 2 years of surgery. A suspicion of retear of the RC led to request of a magnetic resonance image, in which the implant was found located in the acromioclavicular joint. The complications reported with the use of metallic implants around the shoulder led to the development of bioabsorbable anchors. Advantages are their absorption over time, minimizing the risk of migration or interference with revision surgery, less artifacts with magnetic resonance imaging, and tendon-to-bone repair strength similar to metallic anchors. Since the use of bioabsorbable suture anchors is increasing, it is important to know the possible complications associated with these devices.

  6. Bio-absorbable antibiotic impregnated beads for the treatment of prosthetic vascular graft infections.

    Science.gov (United States)

    Genovese, Elizabeth A; Avgerinos, Efthymios D; Baril, Donald T; Makaroun, Michel S; Chaer, Rabih A

    2016-12-01

    There is limited investigation into the use of bio-absorbable antibiotic beads for the treatment of prosthetic vascular graft infections. Our goal was to investigate the rates of infection eradication, graft preservation, and limb salvage in patients who are not candidates for graft explant or extensive reconstruction. A retrospective review of patients implanted with antibiotic impregnated bio-absorbable calcium sulfate beads at a major university center was conducted. Six patients with prosthetic graft infections were treated with bio-absorbable antibiotics beads from 2012-2014. Grafts included an aortobifemoral, an aorto-hepatic/superior mesenteric artery, and four extra-anatomic bypasses. Pathogens included Gram-positive and Gram-negative bacteria. Half of the patients underwent graft explant with reconstruction and half debridement of the original graft, all with antibiotic bead placement around the graft. Mean follow-up was 7.3 ± 8.3 months; all patients had infection resolution, healed wounds, and 100% graft patency, limb salvage, and survival. This report details the successful use of bio-absorbable antibiotic beads for the treatment prosthetic vascular graft infections in patients at high risk for graft explant or major vascular reconstruction. At early follow-up, we demonstrate successful infection suppression, graft preservation, and limb salvage with the use of these beads in a subset of vascular patients. © The Author(s) 2016.

  7. Bio-absorbable antibiotic impregnated beads for the treatment of prosthetic vascular graft infections

    Science.gov (United States)

    Genovese, Elizabeth A; Avgerinos, Efthymios D; Baril, Donald T; Makaroun, Michel S; Chaer, Rabih A

    2017-01-01

    Objective There is limited investigation into the use of bio-absorbable antibiotic beads for the treatment of prosthetic vascular graft infections. Our goal was to investigate the rates of infection eradication, graft preservation, and limb salvage in patients who are not candidates for graft explant or extensive reconstruction. Methods A retrospective review of patients implanted with antibiotic impregnated bio-absorbable calcium sulfate beads at a major university center was conducted. Results Six patients with prosthetic graft infections were treated with bio-absorbable antibiotics beads from 2012–2014. Grafts included an aortobifemoral, an aorto-hepatic/superior mesenteric artery, and four extra-anatomic bypasses. Pathogens included Gram-positive and Gram-negative bacteria. Half of the patients underwent graft explant with reconstruction and half debridement of the original graft, all with antibiotic bead placement around the graft. Mean follow-up was 7.3±8.3 months; all patients had infection resolution, healed wounds, and 100% graft patency, limb salvage, and survival. Conclusion This report details the successful use of bio-absorbable antibiotic beads for the treatment prosthetic vascular graft infections in patients at high risk for graft explant or major vascular reconstruction. At early follow-up, we demonstrate successful infection suppression, graft preservation, and limb salvage with the use of these beads in a subset of vascular patients. PMID:26896286

  8. Food Security and Staple Crops. Staple Food Around the World

    International Nuclear Information System (INIS)

    Kilian, Lizette

    2012-01-01

    Of more than 50,000 edible plant species in the world, only a few hundred contribute significantly to our food supplies. Almost all of the world’s food energy intake is satisfied by just a few crop plants. Rice, maize and wheat make up two-thirds of this already small group of foods. These three grains are the staple foods for more than four billion people both as a source of nutrition and income. A staple crop, by definition, dominates the major part of our diet and supplies a major proportion of our energy and nutrient needs. If staple crops are threatened by drought, pests or nutrient-poor soils, hunger and poverty can rise dramatically.

  9. ARTHROSCOPIC MENISCUS REPAIR WITH BIOABSORBABLE ARROWS IN LOCAL ANESTHESIA

    Directory of Open Access Journals (Sweden)

    Vladimir Senekovič

    2004-11-01

    Full Text Available Background. The menisci have important function in the knee joint. Because of this it is universally accepted that we have to preserve them as much as possible. After open and partially arthroscopic suture techniques new methods of all-inside meniscus repair with bioabsorbable arrows have been developed in the last decade. The meniscus repair using these arrows represents an easy task for a skilled surgeon. In addition, it can be performed in local anesthesia. We have evaluated the results of the first group of patients who were treated by this method.Methods. From February 2001 to August 2002 15 patients with torn meniscuses have been treated at the Clinical Department for Traumatology, University Medical centre, Ljubljana. We repaired their torn menisci arthroscopically with bioabsorbable arrows in local anesthesia. We divided patients in three groups: a group with isolated meniscus injury, a group with meniscus injury and anterior cruciate ligament injury and a group with associated pathology. Four patients had incarcerated meniscuses. Preoperative Lysholm score in the first group was 38, in the second 42 and in the third group 48. We repaired 12 medial and 3 lateral meniscuses. On average we need 45 minutes for therapeutic arthroscopy. Torn meniscus was fixated with minimum of 1 and maximum of 5 bioabsorbable arrows. All patients except one had the affected knee immobilized with cylinder plaster for 15 days on average.Results. At least three months after the arthroscopic fixation of the torn meniscus in local anesthesia another clinical evaluation was made. In all groups significant improvement was observed regarding the range of motions and absence of pain. Postoperative Lysholm score in the first group was 89, in the second 75 and in the third 71. Average deficit of flexion was 3 degrees while extension was full. One patient complained about the same pain in the joint, he underwent another arthroscopy which showed that the meniscus was

  10. Induction of bone ingrowth with a micropore bioabsorbable suture anchor in rotator cuff tear: an experimental study in a rabbit model.

    Science.gov (United States)

    Kang, Yun Gyeong; Kim, Jung-Han; Shin, Jung-Woog; Baik, Jong-Min; Choo, Hye-Jung

    2013-11-01

    The bioabsorbable suture anchor is probably one of the most commonly used tools in arthroscopic shoulder operations. However, there is controversy about whether the bioabsorbable anchor is replaced by bone. The object of this study is to evaluate bone ingrowth into the micropore bioabsorbable suture anchor and the differences in the biomechanical properties of a micropore anchor and a nonpore anchor. A total of 16 microsized holes (diameter, 250 ± 50 μm; depth, 0.2 mm) were made on the bioabsorbable anchors with a microdrill. Twelve adult New Zealand White rabbits were randomly divided into two groups: group A (n = 6), the nonpore bioabsorbable suture anchor group, and group pA (n = 6), the micropore bioabsorbable suture anchor group. Microcomputed tomography was used at 4 and 8 weeks postoperatively to evaluate ingrowth by bone volume fraction (BVF), which was measured by calculating the ratio of the total volume of bone ingrowth to that of the region of interest. For pullout strength testing, 3 additional rabbits (6 limbs) were used for mechanical testing. The mean BVF was higher in group pA (0.288 ± 0.054) than in group A (0.097 ± 0.006). The micropore anchor had a higher pullout strength (0.520 ± 0.294 N) than the nonpore anchor (0.275 ± 0.064 N). Micropore bioabsorbable suture anchors induced bone ingrowth and showed higher pullout strength, despite processing. Copyright © 2013 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  11. A simplified in vivo approach for evaluating the bioabsorbable behavior of candidate stent materials.

    Science.gov (United States)

    Pierson, Daniel; Edick, Jacob; Tauscher, Aaron; Pokorney, Ellen; Bowen, Patrick; Gelbaugh, Jesse; Stinson, Jon; Getty, Heather; Lee, Chee Huei; Drelich, Jaroslaw; Goldman, Jeremy

    2012-01-01

    Metal stents are commonly used to revascularize occluded arteries. A bioabsorbable metal stent that harmlessly erodes away over time may minimize the normal chronic risks associated with permanent implants. However, there is no simple, low-cost method of introducing candidate materials into the arterial environment. Here, we developed a novel experimental model where a biomaterial wire is implanted into a rat artery lumen (simulating bioabsorbable stent blood contact) or artery wall (simulating bioabsorbable stent matrix contact). We use this model to clarify the corrosion mechanism of iron (≥99.5 wt %), which is a candidate bioabsorbable stent material due to its biocompatibility and mechanical strength. We found that iron wire encapsulation within the arterial wall extracellular matrix resulted in substantial biocorrosion by 22 days, with a voluminous corrosion product retained within the vessel wall at 9 months. In contrast, the blood-contacting luminal implant experienced minimal biocorrosion at 9 months. The importance of arterial blood versus arterial wall contact for regulating biocorrosion was confirmed with magnesium wires. We found that magnesium was highly corroded when placed in the arterial wall but was not corroded when exposed to blood in the arterial lumen for 3 weeks. The results demonstrate the capability of the vascular implantation model to conduct rapid in vivo assessments of vascular biomaterial corrosion behavior and to predict long-term biocorrosion behavior from material analyses. The results also highlight the critical role of the arterial environment (blood vs. matrix contact) in directing the corrosion behavior of biodegradable metals. Copyright © 2011 Wiley Periodicals, Inc.

  12. The STAPL pList

    KAUST Repository

    Tanase, Gabriel

    2010-01-01

    We present the design and implementation of the stapl pList, a parallel container that has the properties of a sequential list, but allows for scalable concurrent access when used in a parallel program. The Standard Template Adaptive Parallel Library (stapl) is a parallel programming library that extends C++ with support for parallelism. stapl provides a collection of distributed data structures (pContainers) and parallel algorithms (pAlgorithms) and a generic methodology for extending them to provide customized functionality. stapl pContainers are thread-safe, concurrent objects, providing appropriate interfaces (e.g., views) that can be used by generic pAlgorithms. The pList provides stl equivalent methods, such as insert, erase, and splice, additional methods such as split, and efficient asynchronous (non-blocking) variants of some methods for improved parallel performance. We evaluate the performance of the stapl pList on an IBM Power 5 cluster and on a CRAY XT4 massively parallel processing system. Although lists are generally not considered good data structures for parallel processing, we show that pList methods and pAlgorithms (p-generate and p-partial-sum) operating on pLists provide good scalability on more than 103 processors and that pList compares favorably with other dynamic data structures such as the pVector. © 2010 Springer-Verlag.

  13. Integrated Approaches for the Management of Staple Line Leaks following Sleeve Gastrectomy

    Directory of Open Access Journals (Sweden)

    Mauro Montuori

    2017-01-01

    Full Text Available Introduction. Aim of the study was trying to draw a final flow chart for the management of gastric leaks after laparoscopic sleeve gastrectomy, based on the review of our cases over 10 years’ experience. Material and Methods. We retrospectively reviewed all patients who underwent LSG as a primary operation at the Bariatric Unit of Tor Vergata University Hospital in Rome from 2007 to 2015. Results. Patients included in the study were 418. There were 6 staple line leaks (1.44%. All patients with diagnosis of a leak were initially discharged home in good clinical conditions and then returned to A&E because of the complication. The mean interval between surgery and readmission for leak was 13,4 days (range 6–34 days, SD ± 11.85. We recorded one death (16.67% due to sepsis. The remaining five cases were successfully treated with a mean healing time of the gastric leak of 55,5 days (range 26–83 days; SD ± 25.44. Conclusion. Choosing the proper treatment depends on clinical stability and on the presence or not of collected abscess. Our treatment protocol showed being associated with low complication rate and minor discomfort to the patients, reducing the need for more invasive procedures.

  14. In vitro release of doxycycline from bioabsorbable materials and acrylic strips

    DEFF Research Database (Denmark)

    Larsen, T

    1990-01-01

    Treatment of marginal periodontitis may include use of local antibiotics. In the present in vitro study the bioabsorbable materials Surgicel, Tissell, and CollaCote and acrylic strips were examined for release of doxycycline into liquids and residual antibacterial activity of the materials. Pieces...

  15. MRI of menisci repaired with bioabsorbable arrows

    International Nuclear Information System (INIS)

    Mustonen, Antti O.T.; Kiuru, Martti; Koskinen, Seppo K.; Tielinen, Laura; Lindahl, Jan; Hirvensalo, Eero

    2006-01-01

    To analyze with conventional magnetic resonance imaging (MRI) the signal appearance of menisci repaired with bioabsorbable arrows. Forty-four patients with 47 meniscal tears treated with bioabsorbable arrows underwent follow-up conventional MRI examination. The time interval between the surgery and MRI varied from 5 to 67 months (mean 26 months). Twenty-six patients also had concurrent repair of torn anterior cruciate ligament. The following grades were used to classify meniscal signal intensity: (a) G0; low signal intensity on all sequences and regular configuration in every plane, (b) G1; increased signal intensity within the meniscus, not extending to the meniscal surface, (c) G2; increased signal intensity linear in shape, which may or may not communicate with the capsular margin of the meniscus, without extending to the meniscal surface, and (d) G3; increased signal intensity extending to the meniscal surface. Thirteen menisci (27.5%) had normal signal intensity, 13 menisci (27.5%) Grade 1 signal intensity, 9 menisci (19%) Grade 2 signal intensity and 12 menisci (26%) Grade 3 signal intensity. The time difference between operation and MRI was statistically significant between the G0 (36 months) and G3 groups (14 months; P=0.0288). There was no statistical significance in different grades between medial and lateral meniscus or between patients with operated or intact ACL. On physical examination sixteen patients reported slight symptoms, seen evenly in each group. (orig.)

  16. The Primary Stability of a Bioabsorbable Poly-L-Lactic Acid Suture Anchor for Rotator Cuff Repair Is Not Improved with Polymethylmethacrylate or Bioabsorbable Bone Cement Augmentation.

    Science.gov (United States)

    Güleçyüz, Mehmet F; Kraus-Petersen, Michael; Schröder, Christian; Ficklscherer, Andreas; Wagenhäuser, Markus U; Braun, Christian; Müller, Peter E; Pietschmann, Matthias F

    2018-02-01

    The incidence of osteoporosis and rotator cuff tears increases with age. Cement augmentation of bones is an established method in orthopedic and trauma surgery. This study analyses if polymethylmethacrylate or bioabsorbable cement can improve the primary stability of a bioabsorbable suture anchor in vitro in comparison to a non-augmented suture anchor in osteoporotic human humeri. The trabecular bone mineral density was measured to ensure osteopenic human specimens. Then the poly-l-lactic acid Bio-Corkscrew® FT was implanted in the greater tuberosity footprint with polymethylmethacrylate Refobacin® cement augmentation ( n  = 8), with Cerament™ Bone Void Filler augmentation ( n  = 8) and without augmentation ( n  = 8). Using a cyclic testing protocol, the failure loads, system displacement, and failure modes were recorded. The Cerament™ augmented Bio-Corkscrew® FT yielded the highest failure loads (206.7 N), followed by polymethylmethacrylate Refobacin® augmentation (206.1 N) and without augmentation (160.0 N). The system displacement was lowest for Cerament™ augmentation (0.72 mm), followed by polymethylmethacrylate (0.82 mm) and without augmentation (1.50 mm). Statistical analysis showed no significant differences regarding the maximum failure loads ( p  = 0.1644) or system displacement ( p  = 0.4199). The main mode of failure for all three groups was suture slippage. The primary stability of the Bio-Corkscrew® FT is not influenced by bone cement augmentation with polymethylmethacrylate Refobacin® or with bioabsorbable Cerament™ in comparison to the non-cemented anchors. The cement augmentation of rotator cuff suture anchors in osteoporotic bones remains questionable since biomechanical tests show no significant advantage.

  17. OSTEOSYNTHESIS OF THE METACARPAL BONE WITH BIOABSORBABLE MATERIALS: A CASE REPORTS

    Directory of Open Access Journals (Sweden)

    Ernest Novak

    2004-04-01

    Full Text Available Background. Recent advances in biomaterial technology make it possible to produce easy-to-handle implants for osteosynthesis with ultra-high strenght and excellent biocompatibility. Biomechanical studies have shown that fixation rigidity achieved with self-reinforced (SR pins, screws and miniplates is comparable with that of metallic fixation methods. Internal fixation by means of bioabsorbable plates, screws, and pins can be used to stabilize some fractures of small bones in the hand.We report our experience with three cases where internal fixation with a SR (poly-L/DL-lactide 70/30; SR-P (L/DL LA 70/30, BioSorbTMFX miniplates and screws was carried out for stabilization of a metacarpal shaft fracture and thumb replantation.Conclusions. After bone healing is complete, metallic osteosynthesis devices become unnecessary or can even be harmful. Metallic implant-related long-term complications and secondary removal operation are avoided by using of bioabsorbable osteosynthesis devices for metacarpal bones osteosynthesis.

  18. MRI of broken bioabsorbable crosspin fixation in hamstring graft reconstruction of the anterior cruciate ligament

    Energy Technology Data Exchange (ETDEWEB)

    Bakhru, Prashant [Department of Radiology Jacobi Medical Center, Bronx, NY (United States); Park, Brian [Albert Einstein College of Medicine, Bronx, NY (United States); Umans, Hilary [Department of Radiology Jacobi Medical Center, Bronx, NY (United States); Lenox Hill Radiology and Imaging Associates, P.C., New York, NY (United States); DiFelice, Gregory S. [Hospital for Special Surgery, New York, NY (United States); Tobin, Keith [Lenox Hill Radiology and Imaging Associates, P.C., New York, NY (United States)

    2011-06-15

    To report seven cases of broken bioabsorbable femoral crosspins identified by MRI in evaluation of hamstring grafts of the anterior cruciate ligament. Seven cases of broken bioabsorbable crosspins utilized in femoral fixation of ACL hamstring grafts were identified prospectively and retrospectively from our PACs database during a period from 9/1/08 to 8/31/09. All imaging was performed using 1.5 or 3.0 Tesla MRI and were evaluated for T2 signal within and surrounding the crosspin, osteolysis surrounding the fragments, displacement of fragments, and graft integrity. Time from surgery was also recorded. Seven cases of hamstring grafts with broken bioabsorbable crosspins were imaged 4 months to 3 years following grafting. There was osteolysis surrounding the crosspin in all but one case in which the graft was intact but a pin fragment was displaced into the joint. One graft failed due to aseptic foreign-body reaction to the fixation with aggressive osteolysis at 9 months post surgery. In the remaining five, the ACL graft was either completely torn, partially torn, lax, or degenerative and frayed. Of these, the crosspins were broken and angulated with osteolysis surrounding the apex of the angulated fragment or demonstrated lateral extrusion of the peripheral fragment. Bioabsorbable crosspins utilized in femoral fixation of hamstring graft reconstruction of the ACL may become fractured. While the natural history of osteo-integration of these devices as demonstrated by MRI has not been defined, osteolysis surrounding the fragments, extrusion or displacement of the fragments, and graft laxity or failure would suggest that these are abnormal findings that should be reported. (orig.)

  19. MRI of broken bioabsorbable crosspin fixation in hamstring graft reconstruction of the anterior cruciate ligament

    International Nuclear Information System (INIS)

    Bakhru, Prashant; Park, Brian; Umans, Hilary; DiFelice, Gregory S.; Tobin, Keith

    2011-01-01

    To report seven cases of broken bioabsorbable femoral crosspins identified by MRI in evaluation of hamstring grafts of the anterior cruciate ligament. Seven cases of broken bioabsorbable crosspins utilized in femoral fixation of ACL hamstring grafts were identified prospectively and retrospectively from our PACs database during a period from 9/1/08 to 8/31/09. All imaging was performed using 1.5 or 3.0 Tesla MRI and were evaluated for T2 signal within and surrounding the crosspin, osteolysis surrounding the fragments, displacement of fragments, and graft integrity. Time from surgery was also recorded. Seven cases of hamstring grafts with broken bioabsorbable crosspins were imaged 4 months to 3 years following grafting. There was osteolysis surrounding the crosspin in all but one case in which the graft was intact but a pin fragment was displaced into the joint. One graft failed due to aseptic foreign-body reaction to the fixation with aggressive osteolysis at 9 months post surgery. In the remaining five, the ACL graft was either completely torn, partially torn, lax, or degenerative and frayed. Of these, the crosspins were broken and angulated with osteolysis surrounding the apex of the angulated fragment or demonstrated lateral extrusion of the peripheral fragment. Bioabsorbable crosspins utilized in femoral fixation of hamstring graft reconstruction of the ACL may become fractured. While the natural history of osteo-integration of these devices as demonstrated by MRI has not been defined, osteolysis surrounding the fragments, extrusion or displacement of the fragments, and graft laxity or failure would suggest that these are abnormal findings that should be reported. (orig.)

  20. New technique for fixing rib fracture with bioabsorbable plate.

    Science.gov (United States)

    Oyamatsu, Hironori; Ohata, Norihisa; Narita, Kunio

    2016-09-01

    Fixation of a bone fracture with a bioabsorbable plate made of poly-L-lactide and hydroxyapatite has received attention. We adopted this technique for a rib fracture by bending the plate into a U-shape and fixing it with suture through the holes in the mesh of the plate and holes that are drilled in the edge of the fractured rib. The suture is also wound around the plate. © The Author(s) 2016.

  1. The STAPL pView

    KAUST Repository

    Buss, Antal

    2011-01-01

    The Standard Template Adaptive Parallel Library (STAPL) is a C++ parallel programming library that provides a collection of distributed data structures (pContainers) and parallel algorithms (pAlgorithms) and a generic methodology for extending them to provide customized functionality. STAPL algorithms are written in terms of pViews, which provide a generic access interface to pContainer data by abstracting common data structure concepts. Briefly, pViews allow the same pContainer to present multiple interfaces, e.g., enabling the same pMatrix to be \\'viewed\\' (or used) as a row-major or column-major matrix, or even as a vector. In this paper, we describe the stapl pView concept and its properties. pViews generalize the iterator concept and enable parallelism by providing random access to, and an ADT for, collections of elements. We illustrate how pViews provide support for managing the tradeoff between expressivity and performance and examine the performance overhead incurred when using pViews. © 2011 Springer-Verlag Berlin Heidelberg.

  2. Rectovaginal Fistula after Low Anterior Resection for Rectal Cancer Using a Double Stapling Technique

    Directory of Open Access Journals (Sweden)

    Satoshi Yodonawa

    2010-07-01

    Full Text Available A 55-year-old female underwent low anterior resection for rectal cancer using a double stapling technique. She developed a rectovaginal fistula on the 9th postoperative day. She was discharged from hospital after undergoing transverse colostomy, and 5 months later she underwent transvaginal repair of the rectovaginal fistula. She subsequently had an uneventful recovery. The leading cause of this complication is involvement of the posterior wall of the vagina in the staple line when firing the circular stapler. Transvaginal repair with a diverting stoma for rectovaginal fistula is a safe, minimally invasive and effective method.

  3. Circular stapled anopexy for haemorrhoidal disease: results.

    Science.gov (United States)

    Lehur, P A; Gravié, J F; Meurette, G

    2001-11-01

    Stapled anopexy is a new approach for haemorrhoids requiring surgical treatment. This study reviews the available information concerning the present results of this procedure. Medline and hand search of the literature was conducted to identify available information on the procedure, with a special interest for the on-going or published randomized clinical trials. The advantages of the stapled approach of haemorrhoids were analyzed in the different areas of concern, including postoperative pain reduction, length of hospital stay and sick-leave, postoperative wound care and type and rate of complications. Continence status, symptom cure and patient satisfaction following stapled anopexy are also reported. Stapled anopexy is probably less painful than conventional haemorrhoidectomy. Other advantages in the short term result from this new approach. Long term efficacy of the procedure is still unknown.

  4. Trichobezoar obstruction after stapled jejunal anastomosis in a dog.

    Science.gov (United States)

    Carobbi, Barbara; Foale, Robert D; White, Richard A S

    2009-04-01

    To describe an unusual long-term complication of circular end-to-end anastomosis (CEEA) stapling in a dog. Clinical case report. An 11-year-old, female neutered, Labrador Retriever. The dog was referred for clinical signs of bowel obstruction. An enterectomy was performed 2 years before presentation using a CEEA stapling device. Palpation, plain radiographs, and ultrasound of the abdomen confirmed the presence of a mass in the bowel, causing obstruction, and requiring surgical approach. An exploratory celiotomy revealed a 5 cm mass in the jejunum, involving the site of the previous surgery. The mass was removed by enterectomy. Dissection of the mass revealed the presence of many staples at the previous enterectomy site, and a trichobezoar entangled in the exposed parts of the staples. An enterectomy was required to treat an intestinal obstruction caused by a trichobezoar entangled in a CEEA-stapled anastomosis. Development of trichobezoar and subsequent bowel obstruction should be considered an unusual but potential long-term complication of CEEA-stapled anastomosis.

  5. Gastropexy with an automatic stapling instrument for the treatment of gastric dilatation and volvulus in 20 dogs.

    Science.gov (United States)

    Belandria, Gerardo A; Pavletic, Michael M; Boulay, James P; Penninck, Dominique G; Schwarz, Leslie A

    2009-07-01

    Surgical stapling equipment was used to create a gastropexy in 20 dogs undergoing emergency surgery for gastric dilatation and volvulus (GDV). The technique involved creation of a tunnel between the seromuscular layer and the submucosa of the pyloric antrum, and a matching tunnel beneath the right m. transversus abdominis. The arms of a gastrointestinal anastomosis stapling device were introduced into the tunnels, and the device was fired to create the gastropexy. One dog died of systemic sequelae of GDV during the early postoperative period. None of the remaining 19 dogs developed a recurrence of GDV during follow-up periods ranging from 5 to 43 months. In 11 dogs, the integrity of the gastropexy was evaluated by abdominal ultrasonography and either negative contrast gastrography or double contrast gastrography; in these dogs, the radiographic and/or the ultrasonographic findings were suggestive of an intact gastropexy. There were no complications involving the gastropexy staple line. The results of this study indicate that an effective and consistent permanent gastropexy can be created, using surgical stapling equipment.

  6. Ductility of reinforced concrete columns confined with stapled strips

    International Nuclear Information System (INIS)

    Tahir, M.F.; Khan, Q.U.Z.; Shabbir, F.; Sharif, M.B.; Ijaz, N.

    2015-01-01

    Response of three 150x150x450mm short reinforced concrete (RC) columns confined with different types of confining steel was investigated. Standard stirrups, strips and stapled strips, each having same cross-sectional area, were employed as confining steel around four comer column bars. Experimental work was aimed at probing into the affect of stapled strip confinement on post elastic behavior and ductility level under cyclic axial load. Ductility ratios, strength enhancement factor and core concrete strengths were compared to study the affect of confinement. Results indicate that strength enhancement in RC columns due to strip and stapled strip confinement was not remarkable as compared to stirrup confined column. It was found that as compared to stirrup confined column, stapled strip confinement enhanced the ductility of RC column by 183% and observed axial capacity of stapled strip confined columns was 41 % higher than the strip confined columns. (author)

  7. Graft tendon slippage with metallic and bioabsorbable interference screws under cyclic load: a biomechanical study in a porcine model

    Directory of Open Access Journals (Sweden)

    Ari Digiácomo Ocampo Moré

    Full Text Available Introduction The rupture of the anterior cruciate ligament (ACL is the most common type of knee injury. Reconstructive surgery is the ‘gold standard’ treatment. During the immediate post-operative period, the fixation of the graft is entirely dependent on the ability of the grafted implant to be secured inside the bone tunnel under the cyclical loads associated with daily tasks. Poor fixation can lead to graft slippage, thus impairing the healing and integration of the graft. The aim of this study was to evaluate the biomechanical performance of tendon graft fixation devices with metallic and bioabsorbable interference screws. Methods Twenty ACL reconstructions were carried out in porcine tibias using deep flexor tendons to fix 9 × 20 mm metallic (n=10 and PLLA 70/30 bioabsorbable screws (n=10. To verify the ability of a construct to resist immediate postoperative (PO rehabilitation protocols for immediate load bearing, a cyclic loading test was applied with 50-250 N of tensile force at 1 Hz for 1000 cycles, and the displacement was measured at 10, 50, 100, 500 and 1000 load cycles to quantify the slippage of the graft during the test. After the cyclic loading test, a single-cycle load-to-failure test was applied. Results The slippage of the graft using metallic screws did not differ (P = 0.616 from that observed when using bioabsorbable screws. Conclusion The results obtained in this experiment indicate that metallic screws may promote a similar amount of graft slippage during low cyclic loading as bioabsorbable screws. Additionally, there was no difference in the biomechanical performance of these two types of screws during high failure loads.

  8. In vitro evaluation of various bioabsorbable and nonresorbable barrier membranes for guided tissue regeneration

    Directory of Open Access Journals (Sweden)

    Smeets Ralf

    2008-10-01

    Full Text Available Abstract Background Different types of bioabsorbable and nonresorbable membranes have been widely used for guided tissue regeneration (GTR with its ultimate goal of regenerating lost periodontal structures. The purpose of the present study was to evaluate the biological effects of various bioabsorbable and nonresorbable membranes in cultures of primary human gingival fibroblasts (HGF, periodontal ligament fibroblasts (PDLF and human osteoblast-like (HOB cells in vitro. Methods Three commercially available collagen membranes [TutoDent® (TD, Resodont® (RD and BioGide® (BG] as well as three nonresorbable polytetrafluoroethylene (PTFE membranes [ACE (AC, Cytoplast® (CT and TefGen-FD® (TG] were tested. Cells plated on culture dishes (CD served as positive controls. The effect of the barrier membranes on HGF, PDLF as well as HOB cells was assessed by the Alamar Blue fluorometric proliferation assay after 1, 2.5, 4, 24 and 48 h time periods. The structural and morphological properties of the membranes were evaluated by scanning electron microscopy (SEM. Results The results showed that of the six barriers tested, TD and RD demonstrated the highest rate of HGF proliferation at both earlier (1 h and later (48 h time periods (P P ≤ 0.001. In HOB cell culture, the highest rate of cell proliferation was also calculated for TD at all time periods (P Conclusion Results from the present study suggested that GTR membrane materials, per se, may influence cell proliferation in the process of periodontal tissue/bone regeneration. Among the six membranes examined, the bioabsorbable membranes demonstrated to be more suitable to stimulate cellular proliferation compared to nonresorbable PTFE membranes.

  9. Bioabsorbable Stent Quo Vadis: A Case for Nano-Theranostics

    Science.gov (United States)

    Gundogan, Buket; Tan, Aaron; Farhatnia, Yasmin; Alavijeh, Mohammad S.; Cui, Zhanfeng; Seifalian, Alexander M.

    2014-01-01

    Percutaneous coronary intervention (PCI) is one of the most commonly performed invasive medical procedures in medicine today. Since the first coronary balloon angioplasty in 1977, interventional cardiology has seen a wide array of developments in PCI. Bare metal stents (BMS) were soon superseded by the revolutionary drug-eluting stents (DES), which aimed to address the issue of restenosis found with BMS. However, evidence began to mount against DES, with late-stent thrombosis (ST) rates being higher than that of BMS. The bioabsorbable stent may be a promising alternative, providing vessel patency and support for the necessary time required and thereafter degrade into safe non-toxic compounds which are reabsorbed by the body. This temporary presence provides no triggers for ST, which is brought about by non-endothelialized stent struts and drug polymers remaining in vivo for extended periods of time. Likewise, nano-theranostics incorporated into a bioabsorbable stent of the future may provide an incredibly valuable single platform offering both therapeutic and diagnostic capabilities. Such a stent may allow delivery of therapeutic particles to specific sites thus keeping potential toxicity to a minimum, improved ease of tracking delivery in vivo by embedding imaging agents, controlled rate of therapy release and protection of the implanted therapy. Indeed, nanocarriers may allow an increased therapeutic index as well as offer novel post-stent implantation imaging and diagnostic methods for atherosclerosis, restenosis and thrombosis. It is envisioned that a nano-theranostic stent may well form the cornerstone of future stent designs in clinical practice. PMID:24672583

  10. Isoform-Selective Disruption of AKAP-Localized PKA Using Hydrocarbon Stapled Peptides

    Science.gov (United States)

    2015-01-01

    A-kinase anchoring proteins (AKAPs) play an important role in the spatial and temporal regulation of protein kinase A (PKA) by scaffolding critical intracellular signaling complexes. Here we report the design of conformationally constrained peptides that disrupt interactions between PKA and AKAPs in an isoform-selective manner. Peptides derived from the A Kinase Binding (AKB) domain of several AKAPs were chemically modified to contain an all-hydrocarbon staple and target the docking/dimerization domain of PKA-R, thereby occluding AKAP interactions. The peptides are cell-permeable against diverse human cell lines, are highly isoform-selective for PKA-RII, and can effectively inhibit interactions between AKAPs and PKA-RII in intact cells. These peptides can be applied as useful reagents in cell-based studies to selectively disrupt AKAP-localized PKA-RII activity and block AKAP signaling complexes. In summary, the novel hydrocarbon-stapled peptides developed in this study represent a new class of AKAP disruptors to study compartmentalized RII-regulated PKA signaling in cells. PMID:24422448

  11. Overlapping bio-absorbable scaffolds: Aim for D2D technique?

    Science.gov (United States)

    Khan, Asaad A; Dangas, George D

    2018-06-01

    The results of overlapping metallic stents have been concerning but this practice is often unavoidable in the setting of long or tortuous lesions, diameter discrepancy of proximal and distal vessel, and for residual dissections. Theoretically, bio-absorbable scaffolds may carry an advantage over metallic stents due to the progressive resorption of the scaffold theoretically rendering the overlap a non-issue; this has not been clinically evident. Since stent/scaffold overlap cannot be entirely avoided, improved stent delivery/deployment and scaffold design modification may reduce complications in this complex patient subset. © 2018 Wiley Periodicals, Inc.

  12. The STAPL pView

    KAUST Repository

    Buss, Antal; Fidel, Adam; Harshvardhan,; Smith, Timmie; Tanase, Gabriel; Thomas, Nathan; Xu, Xiabing; Bianco, Mauro; Amato, Nancy M.; Rauchwerger, Lawrence

    2011-01-01

    The Standard Template Adaptive Parallel Library (STAPL) is a C++ parallel programming library that provides a collection of distributed data structures (pContainers) and parallel algorithms (pAlgorithms) and a generic methodology for extending them

  13. Closing the medullary canal after retrograde nail removal using a bioabsorbable bone plug: technical tip

    NARCIS (Netherlands)

    Schepers, T.; Vogels, L. M. M.

    2012-01-01

    We describe a simple technique for closure of the intra-articular opening after the removal of a retrograde femur nail. With the use of a gelatine bioabsorbable bone plug the medullary canal is closed, reducing leakage of blood and cancellous bone particles from the bone into the knee joint

  14. Accuracy of multidetector CT in detecting anastomotic leaks following stapled left-sided colonic anastomosis

    International Nuclear Information System (INIS)

    Kaur, P.; Karandikar, S.S.; Roy-Choudhury, S.

    2014-01-01

    Aims: To assess accuracy of multidetector computed tomography (MDCT) and individual radiological signs in the diagnosis of anastomotic leaks. Materials and methods: Patients undergoing anterior resection with a stapled anastomosis over a 2 year period were identified. Electronic and clinical records of these patients were reviewed. Unenhanced and/or enhanced MDCT was performed with intravenous and/or per-rectal contrast medium and read by a radiologist blinded to the patients' clinical details to determine the sensitivity and specificity of specific findings at MDCT for identifying leaks. Results: Seventeen percent (30/170) of the anterior resections were suspected to have an anastomotic leak. Ninety-three percent (28/30) of patients underwent MDCT. Seven point six percent (11+2/170) had a confirmed leak. Two patients underwent surgery without MDCT. A leak was confirmed by MDCT in 91% (10/11) of patients. The sensitivity, specificity, and positive and negative predictive values of MDCT in diagnosing a leak was 0.91, 1, 1, and 0.95, respectively. The sensitivity of peri-anastomotic air, peri-anastomotic collection, extravasation of rectal contrast medium, and staple line integrity was 0.81, 0.63, 0.54, and 0.72, respectively. Use of rectal contrast medium (8/11 cases) increased the subjective ease of diagnosis and was the only sign in one patient. Conclusions: Presence of peri-anastomotic air is a reliable marker of anastomotic leaks at MDCT. Leakage of rectal contrast medium is highly accurate and increases confidence of diagnosis. The appearance of the staple line itself is not accurate in assessing anastomotic integrity

  15. The STAPL pList

    KAUST Repository

    Tanase, Gabriel; Xu, Xiabing; Buss, Antal; Harshvardhan,; Papadopoulos, Ioannis; Pearce, Olga; Smith, Timmie; Thomas, Nathan; Bianco, Mauro; Amato, Nancy M.; Rauchwerger, Lawrence

    2010-01-01

    We present the design and implementation of the stapl pList, a parallel container that has the properties of a sequential list, but allows for scalable concurrent access when used in a parallel program. The Standard Template Adaptive Parallel

  16. Reverse Transrectal Stapling Technique Using the EEA Stapler: An ...

    African Journals Online (AJOL)

    Reverse Transrectal Stapling Technique Using the EEA Stapler: An Alternative Approach in Difficult Reversal of Hartmann's Procedure. SK Zachariah. Abstract. The introduction of circular end-to-end stapling devices (CEEA OR EEA stapler) into colorectal surgery have revolutionised anastomotic techniques. The EEA ...

  17. Internal fixation of proximal fractures of the 2nd and 4th metacarpal and metatarsal bones using bioabsorbable screws.

    Science.gov (United States)

    Mageed, M; Steinberg, T; Drumm, N; Stubbs, N; Wegert, J; Koene, M

    2018-03-01

    Fractures involving the proximal one-third of the splint bone are relatively rare and are challenging to treat. A variety of management techniques have been reported in the literature. The aim of this retrospective case series was to describe the clinical presentation and evaluate the efficacy of bioabsorbable polylactic acid screws in internal fixation of proximal fractures of the 2nd and 4th metacarpal and metatarsal bones in horses. The medical records, diagnostic images and outcome of all horses diagnosed with a proximal fracture of the splint bones and treated with partial resection and internal fixation of the proximal stump using bioabsorbable polylactic acid screws between 2014 and 2015 were reviewed. Eight horses met the inclusion criteria. The results showed that there were no complications encountered during screw placement or postoperatively. Six horses returned to full work 3 months after the operation and two horses remained mildly lame. On follow-up radiographs 12 months postoperatively (n = 2) the screws were not completely absorbed. The screws resulted in a cone-shaped radiolucency, which was progressively replaced from the outer margins by bone sclerosis. The use of bioabsorbable screws for fixation of proximal fractures of the splint bone appears to be a safe and feasible technique and may offer several advantages over the use of traditional metallic implants. © 2018 Australian Veterinary Association.

  18. Stapled hemorrhoidopexy: The Aga Khan University Hospital Experience

    International Nuclear Information System (INIS)

    Athar, Ali; Chawla, Tabish; Turab, Pishori

    2009-01-01

    Stapled hemorrhoidopexy for prolapsing hemorrhoids is conceptually different from excision hemorrhoidectomy. It does not accompany the pain that usually occurs after resection of the sensitive anoderm. This study was carried out to evaluate the clinical outcome of stapled hemorrhoidopexy at The Aga Khan University Hospital. A sample of 140 patients with symptomatic second-, third-, and fourth-degree hemorrhoids and circumferential mucosal prolapse underwent stapled hemorrhoidopexy from July 2002 to July 2007. They were evaluated for postoperative morbidity, analgesic requirement, and recurrence. Seventy-eight percent were males and the mean age was 45 (range 16-90) years. The mean operative time was 35 (15-78) min. The mean parenteral analgesic doses during the first 24 h were 2.1. All patients received oral analgesics alone after 24 h. No significant postoperative morbidity was observed. The mean in-patient hospital stay was 1.3 (0-5) days. Patients were followed-up for 24 (range, 2-48) months. Minor local recurrence of hemorrhoids was seen in four patients and was managed by band ligation. Stapled hemorrhoidopexy procedure was found safe, well tolerated by patients with minimal parenteral analgesic use and early discharge from the hospital. (author)

  19. Magnesium as a biodegradable and bioabsorbable material for medical implants

    Science.gov (United States)

    Brar, Harpreet S.; Platt, Manu O.; Sarntinoranont, Malisa; Martin, Peter I.; Manuel, Michele V.

    2009-09-01

    For many years, stainless steel, cobalt-chromium, and titanium alloys have been the primary biomaterials used for load-bearing applications. However, as the need for structural materials in temporary implant applications has grown, materials that provide short-term structural support and can be reabsorbed into the body after healing are being sought. Since traditional metallic biomaterials are typically biocompatible but not biodegradable, the potential for magnesium-based alloys in biomedical applications has gained more interest. This paper summarizes the history and current status of magnesium as a bioabsorbable implant material. Also discussed is the development of a magnesium-zinc-calcium alloy that demonstrates promising degradation behavior.

  20. The STAPL Parallel Graph Library

    KAUST Repository

    Harshvardhan,; Fidel, Adam; Amato, Nancy M.; Rauchwerger, Lawrence

    2013-01-01

    This paper describes the stapl Parallel Graph Library, a high-level framework that abstracts the user from data-distribution and parallelism details and allows them to concentrate on parallel graph algorithm development. It includes a customizable

  1. Use of a Fibrinogen/Thrombin-Based Collagen Fleece (TachoComb, TachoSil) With a Stapled Closure to Prevent Pancreatic Fistula Formation Following Distal Pancreatectomy.

    Science.gov (United States)

    Mita, Kazuhito; Ito, Hideto; Murabayashi, Ryo; Asakawa, Hideki; Nabetani, Masashi; Kamasako, Akira; Koizumi, Kazuya; Hayashi, Takashi

    2015-12-01

    Postoperative pancreatic fistula formation remains a source of significant morbidity following distal pancreatectomy. The aim of this study was to evaluate the rate of clinically significant fistulas (International Study Group on Pancreatic Fistula grade B and grade C) after distal pancreatectomy using a fibrinogen/thrombin-based collagen fleece (TachoComb, TachoSil) with a stapled closure. Seventy-five patients underwent distal pancreatectomy at our institution between January 2005 and March 2014. A fibrinogen/thrombin-based collagen fleece was applied to the staple line of the pancreas before stapling. Twenty-six patients (34.7%) developed a pancreatic fistula, 8 patients (10.7%) developed a grade B fistula, and no patients developed a grade C fistula. The duration of the drain was significantly different in patients with or without a pancreatic fistula (8.0 ± 4.5 vs. 5.4 ± 1.3 days, P = .0003). Histological analysis showed that there was a tight covering with the fibrinogen/thrombin-based collagen fleece. The fibrinogen/thrombin-based collagen fleece (TachoComb, TachoSil) with a stapled closure has low rates of fistula formation and provides a safe alternative to the conventional stapled technique in distal pancreatectomy. © The Author(s) 2015.

  2. Comparison of in vivo acute stent recoil between the bioabsorbable everolimus-eluting coronary stent and the everolimus-eluting cobalt chromium coronary stent: insights from the ABSORB and SPIRIT trials

    DEFF Research Database (Denmark)

    Tanimoto, Shuzou; Serruys, Patrick W; Thuesen, Leif

    2007-01-01

    OBJECTIVES: This study sought to evaluate and compare in vivo acute stent recoil of a novel bioabsorbable stent and a metallic stent. BACKGROUND: The bioabsorbable everolimus-eluting coronary stent (BVS) is composed of a poly-L-lactic acid backbone, coated with a bioabsorbable polymer containing...... the antiproliferative drug, everolimus, and expected to be totally metabolized and absorbed in the human body. Because the BVS is made from polymer, it may have more acute recoil than metallic stents in vivo. METHODS: A total of 54 patients, who underwent elective stent implantation for single de novo native coronary...... artery lesions, were enrolled: 27 patients treated with the BVS and 27 patients treated with the everolimus-eluting cobalt chromium stent (EES). Acute absolute recoil, assessed by quantitative coronary angiography, was defined as the difference between mean diameter of the last inflated balloon...

  3. Patent foramen ovale closure using a bioabsorbable closure device: safety and efficacy at 6-month follow-up.

    Science.gov (United States)

    Van den Branden, Ben J; Post, Martijn C; Plokker, Herbert W; ten Berg, Jurriën M; Suttorp, Maarten J

    2010-09-01

    The aim of this study was to assess the mid-term safety and efficacy of percutaneous patent foramen ovale (PFO) closure using a bioabsorbable device (BioSTAR, NMT Medical, Boston, Massachusetts). Closure of PFO in patients with cryptogenic stroke has proven to be safe and effective using different types of permanent devices. All consecutive patients who underwent percutaneous PFO closure with the bioabsorbable closure device between November 2007 and January 2009 were included. Residual shunt was assessed using contrast transthoracic echocardiography. Sixty-two patients (55% women, mean age 47.7 ± 11.8 years) underwent PFO closure. The in-hospital complications were a surgical device retrieval in 2 patients (3.2%), device reposition in 1 (1.6%), and a minimal groin hematoma in 6 patients (9.7%). The short-term complications at 1-month follow-up (n = 60) were a transient ischemic attack in the presence of a residual shunt in 1 patient and new supraventricular tachycardia in 7 patients (11.3%). At 6-month follow-up (n = 60), 1 patient without residual shunt developed a transient ischemic attack and 1 developed atrial fibrillation. A mild or moderate residual shunt was noted in 51.7%, 33.9%, and 23.7% after 1-day, 1-month, and 6-month follow-up, respectively. A large shunt was present in 8.3%, 3.4%, and 0% after 1-day, 1-month, and 6-month follow-up. Closure of PFO using the bioabsorbable device is associated with a low complication rate and a low recurrence rate of embolic events. However, a relatively high percentage of mild or moderate residual shunting is still present at 6-month follow-up. Copyright © 2010 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  4. Early functional outcome of a modified Brostrom-Gould surgery using bioabsorbable suture anchor for chronic lateral ankle instability.

    Science.gov (United States)

    Shahrulazua, A; Ariff Sukimin, M S; Tengku Muzaffar, T M; Yusof, M I

    2010-03-01

    The purpose of this study was to evaluate the early functional outcome following the use of a bioabsorbable suture anchor to simplify the repair of injured lateral ankle structures as a variation of an established technique known as the Brostrom-Gould procedure. This was a prospective study of 30 ankles with chronic lateral instability that underwent a modified Brostrom-Gould surgery using a bioabsorbable suture anchor, performed by a single surgeon. A total of 29 patients, aged 15 to 52 (mean is 33) years, were enrolled in the study. The follow-up period ranged from three to six (mean is four) months. The function of the patients' ankles was scored using the Kaikkonen Functional Scale, both preoperatively and postoperatively. Preoperatively, all ankles had poor scores (less than 50). Postoperatively, 28 ankles showed excellent scores and two ankles showed good scores, while none obtained a fair or poor score. The difference in the overall means between the postoperative and preoperative scores was statistically significant (p-value is 0.001). Post surgery, 24 ankles had no symptoms, while six had only mild ankle tightness with extreme inversion movement at the last review. All patients were able to walk normally, and 29 ankles regained their normal running capability. There was marked improvement in the ability to descend stairs, to rise on heels and toes, to perform a single-limb stance, and in range of motions of the ankle dorsiflexion as well as in ankle laxity. The modified Brostrom-Gould procedure using a bioabsorbable suture anchor allowed for early ankle rehabilitation and offered a reproducible and excellent early functional outcome with minimal complications.

  5. Influence of Surgical Staples on Radiofrequency Ablation Using Multitined Expandable Electrodes

    International Nuclear Information System (INIS)

    Sakuhara, Yusuke; Shimizu, Tadashi; Abo, Daisuke; Hasegawa, Yu; Kato, Fumi; Kodama, Yoshihisa; Shirato, Hiroki

    2007-01-01

    Purpose. During radiofrequency ablation (RFA), there is a risk that the multitined expandable electrode will come into contact with one of the surgical staples used to treat local recurrence after surgical operations. Our objective was to evaluate whether a surgical staple would influence the RFA of egg white using a multitined expandable electrode. Methods. Multitined expandable electrodes, LeVeen needles (expandable diameter 3.0 cm), were sunk into an egg white bath with (a) no surgical staple, (b) a surgical staple touching one of the tines, or (c) a surgical staple touching two of the tines simultaneously. By connecting the LeVeen needle and copper plate at the bottom of the bath, RFA was then performed on the egg whites as a substitute for human tissue. Ten egg white baths were ablated under each of conditions (a), (b), and (c), for a total of 30 sets of coagulated egg white. Results. There was no significant difference in the time from the power-on to the roll-off (i.e., the completion and shutting off of the electric circuit) or in the maximum diameter of the thermal lesion between conditions (a) and (b) or (a) and (c). However, the minimum diameter of the thermal lesion was significantly smaller in (c) compared with (a) (p < 0.01). Conclusions. Surgical staples have the capacity to interfere with the electromagnetic field and decrease the minimum diameter of the thermal lesion in the event that a staple touches two of the tines of a multitined expandable electrode during RFA. Although the difference might be small enough to be neglected under many clinical circumstances, we recommend that, if possible, the tines not be expanded near metallic material

  6. Is STAPLE algorithm confident to assess segmentation methods in PET imaging?

    International Nuclear Information System (INIS)

    Dewalle-Vignion, Anne-Sophie; Betrouni, Nacim; Vermandel, Maximilien; Baillet, Clio

    2015-01-01

    Accurate tumor segmentation in [18F]-fluorodeoxyglucose positron emission tomography is crucial for tumor response assessment and target volume definition in radiation therapy. Evaluation of segmentation methods from clinical data without ground truth is usually based on physicians’ manual delineations. In this context, the simultaneous truth and performance level estimation (STAPLE) algorithm could be useful to manage the multi-observers variability. In this paper, we evaluated how this algorithm could accurately estimate the ground truth in PET imaging.Complete evaluation study using different criteria was performed on simulated data. The STAPLE algorithm was applied to manual and automatic segmentation results. A specific configuration of the implementation provided by the Computational Radiology Laboratory was used.Consensus obtained by the STAPLE algorithm from manual delineations appeared to be more accurate than manual delineations themselves (80% of overlap). An improvement of the accuracy was also observed when applying the STAPLE algorithm to automatic segmentations results.The STAPLE algorithm, with the configuration used in this paper, is more appropriate than manual delineations alone or automatic segmentations results alone to estimate the ground truth in PET imaging. Therefore, it might be preferred to assess the accuracy of tumor segmentation methods in PET imaging. (paper)

  7. Is STAPLE algorithm confident to assess segmentation methods in PET imaging?

    Science.gov (United States)

    Dewalle-Vignion, Anne-Sophie; Betrouni, Nacim; Baillet, Clio; Vermandel, Maximilien

    2015-12-01

    Accurate tumor segmentation in [18F]-fluorodeoxyglucose positron emission tomography is crucial for tumor response assessment and target volume definition in radiation therapy. Evaluation of segmentation methods from clinical data without ground truth is usually based on physicians’ manual delineations. In this context, the simultaneous truth and performance level estimation (STAPLE) algorithm could be useful to manage the multi-observers variability. In this paper, we evaluated how this algorithm could accurately estimate the ground truth in PET imaging. Complete evaluation study using different criteria was performed on simulated data. The STAPLE algorithm was applied to manual and automatic segmentation results. A specific configuration of the implementation provided by the Computational Radiology Laboratory was used. Consensus obtained by the STAPLE algorithm from manual delineations appeared to be more accurate than manual delineations themselves (80% of overlap). An improvement of the accuracy was also observed when applying the STAPLE algorithm to automatic segmentations results. The STAPLE algorithm, with the configuration used in this paper, is more appropriate than manual delineations alone or automatic segmentations results alone to estimate the ground truth in PET imaging. Therefore, it might be preferred to assess the accuracy of tumor segmentation methods in PET imaging.

  8. Characterization of materials eliciting foreign body reaction in stapled human gastrointestinal anastomoses.

    Science.gov (United States)

    Lim, C B B; Goldin, R D; Darzi, A; Hanna, G B

    2008-08-01

    Staples are made of titanium, which elicits minimal tissue reaction. The authors have encountered foreign body reaction associated with stapled human gastrointestinal anastomoses, although the literature has no reports of this. The aim of this study was to identify the refractile foreign materials causing this reaction. Histological sections were taken from 14 gastrointestinal specimens from patients with a history of a stapled anastomosis within the specimen excised. These were reviewed by light and polarization microscopy. Scanning electron microscopy and energy dispersive X-ray analysis were carried out on these sections, staples and stapler cartridges used for gastrointestinal surgery. Foreign bodies rich in fluorine were found in three patients, and those rich in carbon in 12. Other elements identified included oxygen, calcium, sodium, potassium, magnesium, aluminium and silicon. One specimen was found to contain titanium with no surrounding foreign body reaction. Stapler cartridges contained carbon, oxygen, fluorine, calcium, sodium, potassium, magnesium, aluminium, silicon and traces of titanium. Staples were composed of pure titanium with some fibrous material on the surface containing elements found in stapler cartridges. The presence of foreign body reaction was confirmed in stapled human gastrointestinal anastomoses. The source of refractile materials eliciting this reaction was the stapler cartridges. (c) 2008 British Journal of Surgery Society Ltd. Published by John Wiley & Sons, Ltd.

  9. Software in windows for staple compounding system of microcomputer nuclear mass scale

    International Nuclear Information System (INIS)

    Wang Yanting; Zhang Yongming; Wang Yu; Jin Dongping

    1998-01-01

    The software exploited in windows for staple compounding system of microcomputer nuclear mass scale is described. The staple compounding system is briefly narrated. The software structure and its realizing method are given

  10. Will Transition of Staple Food Strategy in China Really Mitigate Global Climate Change?

    Science.gov (United States)

    Liu, B.; Zhao, D.

    2017-12-01

    With the increase in agricultural demand, reducing greenhouse gas (GHG) emissions is a vital challenge in mitigating climate change. Potato staple food strategy in China introduced by Ministry of Agriculture in 2015 is to gradually adjust staple food structure, which provides an opportunity to meet with the challenge. Apart from staple food structure, difference on energy, material input, geography, and crop management are essential to determine agriculture's contribution to climate change. In this study, we conduct a life cycle analysis of four staple foods in China, namely rice, wheat, maize, and potato, to develop crop-specific estimates of GHG emissions and GHG intensity by using `Production intensity' (carbon dioxide equivalent emissions per kilocalorie produced), to help us understand potential synergies and frictions between food producing and climate mitigation. Data used in this study is on city / province levels if city level is unavailable in 2015. First, we evaluate GHG reductions due to transition of staple food structure in China. Staple food GHG emissions in China are 546.90 Tg CO2e yr-1 in 2015, with 47.6%, 21.9%, 27.3% and 3.2% from rice, wheat, maize and potato. Mean production intensity of staple food is 0.45 Mg CO2e M kcal-1 in 2015. Maize leads the intensity with 0.77 Mg CO2e M kcal-1, followed by rice (0.49 Mg CO2e M kcal-1), wheat (0.28 Mg CO2e M kcal-1) and potato (0.24 Mg CO2e M kcal-1). After staple food structure adjustment, 25 Tg CO2e yr-1 (4.2%) reduction will be accomplished in 2020 without any crop management improvement. Further reduction (33.3% - 40.4%) could be achieved with crop management improvement. In addition, because of staple food structure switching, native rice production will decline, which might lead to more export from countries with higher production intensity. Estimated emission leakage from rice import is 30.10 Tg CO2e yr-1, exceeds emission reduction in native China. Therefore, potato staple food strategy could

  11. Evaluation of Nitinol staples for the Lapidus arthrodesis in a reproducible biomechanical model

    Directory of Open Access Journals (Sweden)

    Nicholas Alexander Russell

    2015-12-01

    Full Text Available While the Lapidus procedure is a widely accepted technique for treatment of hallux valgus, the optimal fixation method to maintain joint stability remains controversial. The purpose of this study was to evaluate the biomechanical properties of new Shape Memory Alloy staples arranged in different configurations in a repeatable 1st Tarsometatarsal arthrodesis model. Ten sawbones models of the whole foot (n=5 per group were reconstructed using a single dorsal staple or two staples in a delta configuration. Each construct was mechanically tested in dorsal four-point bending, medial four-point bending, dorsal three-point bending and plantar cantilever bending with the staples activated at 37°C. The peak load, stiffness and plantar gapping were determined for each test. Pressure sensors were used to measure the contact force and area of the joint footprint in each group. There was a significant (p < 0.05 increase in peak load in the two staple constructs compared to the single staple constructs for all testing modalities. Stiffness also increased significantly in all tests except dorsal four-point bending. Pressure sensor readings showed a significantly higher contact force at time zero and contact area following loading in the two staple constructs (p < 0.05. Both groups completely recovered any plantar gapping following unloading and restored their initial contact footprint. The biomechanical integrity and repeatability of the models was demonstrated with no construct failures due to hardware or model breakdown. Shape memory alloy staples provide fixation with the ability to dynamically apply and maintain compression across a simulated arthrodesis following a range of loading conditions.

  12. Frequency of Dehiscence in Hand-Sutured and Stapled Intestinal Anastomoses in Dogs.

    Science.gov (United States)

    Duell, Jason R; Thieman Mankin, Kelley M; Rochat, Mark C; Regier, Penny J; Singh, Ameet; Luther, Jill K; Mison, Michael B; Leeman, Jessica J; Budke, Christine M

    2016-01-01

    To determine the frequency of dehiscence of hand-sutured and stapled intestinal anastomoses in the dog and compare the surgery duration for the methods of anastomosis. Historical cohort study. Two hundred fourteen client-owned dogs undergoing hand-sutured (n = 142) or stapled (n = 72) intestinal anastomoses. Medical records from 5 referral institutions were searched for dogs undergoing intestinal resection and anastomosis between March 2006 and February 2014. Demographic data, presence of septic peritonitis before surgery, surgical technique (hand-sutured or stapled), surgery duration, surgeon (resident versus faculty member), indication for surgical intervention, anatomic location of resection and anastomosis, and if dehiscence was noted postoperatively were retrieved. Estimated frequencies were summarized and presented as proportions and 95% confidence intervals (CI) and continuous outcomes as mean (95% CI). Comparisons were made across methods of anastomosis. Overall, 29/205 dogs (0.14, 95% CI 0.10-00.19) had dehiscence, including 21/134 dogs (0.16, 0.11-0.23) undergoing hand-sutured anastomosis and 8/71 dogs (0.11, 0.06-0.21) undergoing stapled anastomosis. There was no significant difference in the frequency of dehiscence across anastomosis methods (χ(2), P = .389). The mean (95% CI) surgery duration of 140 minutes (132-147) for hand- sutured anastomoses and 108 minutes (99-119) for stapled anastomoses was significantly different (t-test, P < .001). No significant difference in frequency of dehiscence was noted between hand- sutured and stapled anastomoses in dogs but surgery duration is significantly reduced by the use of staples for intestinal closure. © Copyright 2015 by The American College of Veterinary Surgeons.

  13. 76 FR 11268 - Certain Polyester Staple Fiber From Korea and Taiwan

    Science.gov (United States)

    2011-03-01

    ... Polyester Staple Fiber From Korea and Taiwan AGENCY: United States International Trade Commission. ACTION... Korea and Taiwan. SUMMARY: The Commission hereby gives notice that it has instituted reviews pursuant to... the antidumping duty orders on certain polyester staple fiber from Korea and Taiwan would be likely to...

  14. One stage functional end-to-end stapled intestinal anastomosis and resection performed by nonexpert surgeons for the treatment of small intestinal obstruction in 30 dogs.

    Science.gov (United States)

    Jardel, Nicolas; Hidalgo, Antoine; Leperlier, Dimitri; Manassero, Mathieu; Gomes, Aymeric; Bedu, Anne Sophie; Moissonnier, Pierre; Fayolle, Pascal; Begon, Dominique; Riquois, Elisabeth; Viateau, Véronique

    2011-02-01

    To describe stapled 1-stage functional end-to-end intestinal anastomosis for treatment of small intestinal obstruction in dogs and evaluate outcome when the technique is performed by nonexpert surgeons after limited training in the technique. Case series. Dogs (n=30) with intestinal lesions requiring an enterectomy. Stapled 1-stage functional end-to-end anastomosis and resection using a GIA-60 and a TA-55 stapling devices were performed under supervision of senior residents and faculty surgeons by junior surgeons previously trained in the technique on pigs. Procedure duration and technical problems were recorded. Short-term results were collected during hospitalization and at suture removal. Long-term outcome was established by clinical and ultrasonographic examinations at least 2 months after surgery and from written questionnaires, completed by owners. Mean±SD procedure duration was 15±12 minutes. Postoperative recovery was uneventful in 25 dogs. One dog had anastomotic leakage, 1 had a localized abscess at the transverse staple line, and 3 dogs developed an incisional abdominal wall abscess. No long-term complications occurred (follow-up, 2-32 months). Stapled 1-stage functional end-to-end anastomosis and resection is a fast and safe procedure in the hand of nonexpert but trained surgeons. © Copyright 2011 by The American College of Veterinary Surgeons.

  15. Evaluation of Nitinol Staples for the Lapidus Arthrodesis in a Reproducible Biomechanical Model.

    Science.gov (United States)

    Russell, Nicholas A; Regazzola, Gianmarco; Aiyer, Amiethab; Nomura, Tomohiro; Pelletier, Matthew H; Myerson, Mark; Walsh, William R

    2015-01-01

    While the Lapidus procedure is a widely accepted technique for treatment of hallux valgus, the optimal fixation method to maintain joint stability remains controversial. The purpose of this study is to evaluate the biomechanical properties of new shape memory alloy (SMA) staples arranged in different configurations in a repeatable first tarsometatarsal arthrodesis model. Ten sawbones models of the whole foot (n = 5 per group) were reconstructed using a single dorsal staple or two staples in a delta configuration. Each construct was mechanically tested non-destructively in dorsal four-point bending, medial four-point bending, dorsal three-point bending, and plantar cantilever bending with the staples activated at 37°C. The peak load (newton), stiffness (newton per millimeter), and plantar gapping (millimeter) were determined for each test. Pressure sensors were used to measure the contact force and area of the joint footprint in each group. There was a statistically significant increase in peak load in the two staple constructs compared to the single staple constructs for all testing modalities with P values range from 0.016 to 0.000. Stiffness also increased significantly in all tests except dorsal four-point bending. Pressure sensor readings showed a significantly higher contact force at time zero (P = 0.037) and contact area following loading in the two staple constructs (P = 0.045). Both groups completely recovered any plantar gapping following unloading and restored their initial contact footprint. The biomechanical integrity and repeatability of the models was demonstrated with no construct failures due to hardware or model breakdown. SMA staples provide fixation with the ability to dynamically apply and maintain compression across a simulated arthrodesis following a range of loading conditions.

  16. Exploitation of the Ornithine Effect Enhances Characterization of Stapled and Cyclic Peptides

    Science.gov (United States)

    Crittenden, Christopher M.; Parker, W. Ryan; Jenner, Zachary B.; Bruns, Kerry A.; Akin, Lucas D.; McGee, William M.; Ciccimaro, Eugene; Brodbelt, Jennifer S.

    2016-05-01

    A method to facilitate the characterization of stapled or cyclic peptides is reported via an arginine-selective derivatization strategy coupled with MS/MS analysis. Arginine residues are converted to ornithine residues through a deguanidination reaction that installs a highly selectively cleavable site in peptides. Upon activation by CID or UVPD, the ornithine residue cyclizes to promote cleavage of the adjacent amide bond. This Arg-specific process offers a unique strategy for site-selective ring opening of stapled and cyclic peptides. Upon activation of each derivatized peptide, site-specific backbone cleavage at the ornithine residue results in two complementary products: the lactam ring-containing portion of the peptide and the amine-containing portion. The deguanidination process not only provides a specific marker site that initiates fragmentation of the peptide but also offers a means to unlock the staple and differentiate isobaric stapled peptides.

  17. Will fortification of staple foods make a difference to the dietary ...

    African Journals Online (AJOL)

    These values were then interpolated in the original staple food nutrient analysis determined in the primary analysis of the NFCS database. Findings: The findings of the present study indicated that the addition of micronutrients to staple foods made a significant difference to the intake of vitamin A, thiamine, niacin, vitamin B6, ...

  18. 76 FR 58040 - Certain Polyester Staple Fiber From Korea and Taiwan

    Science.gov (United States)

    2011-09-19

    ... Polyester Staple Fiber From Korea and Taiwan Determination On the basis of the record \\1\\ developed in the... antidumping duty orders on certain polyester staple fiber from Korea and Taiwan would be likely to lead to continuation or recurrence of material injury to an industry in the United States within a reasonably...

  19. Preparation and Characterization of Nitinol Bone Staples for Cranio-Maxillofacial Surgery

    Science.gov (United States)

    Lekston, Z.; Stróż, D.; Jędrusik-Pawłowska, M.

    2012-12-01

    The aim of this work was to form NiTi and TiNiCo body temperature activated and superelastic staples for clinical joining of mandible and face bone fractures. The alloys were obtained by VIM technique. Hot and cold processing was applied to obtain wires of required diameters. The martensitic transformation was studied by DSC, XRD, and TEM. The shape memory effects were measured by a bend and free recovery ASTM F2082-06 test. The superelasticity was recorded in the tension stress-strain and by the three-point bending cycles in an instrument equipped with a Hottinger force transducer and LVDT. Excellent superelastic behavior of TiNiCo wires was obtained after cold working and annealing at 400-500 °C. The body temperature activated shape memory staples were applied for fixation of mandibular condyle fractures. In experiments on the skull models, fixation of the facial fractures by using shape memory and superelastic staples were compared. The superelastic staples were used in osteosynthesis of zygomatico-maxillo-orbital fractures.

  20. Will fortification of staple foods make a difference to the dietary ...

    African Journals Online (AJOL)

    vitamins A, D, C and E, riboflavin, niacin, vitamin B6 and folic acid ... beverages such as milk powder, and staple foods rich in energy.13,14 ... then interpolated in the original staple food nutrient analysis determined in the primary analysis of the NFCS ... the market.28,29 The amount of these foods consumed by each child.

  1. Pricing of Staple Foods at Supermarkets versus Small Food Stores.

    Science.gov (United States)

    Caspi, Caitlin E; Pelletier, Jennifer E; Harnack, Lisa J; Erickson, Darin J; Lenk, Kathleen; Laska, Melissa N

    2017-08-15

    Prices affect food purchase decisions, particularly in lower-income communities, where access to a range of food retailers (including supermarkets) is limited. The aim of this study was to examine differences in staple food pricing between small urban food stores and the closest supermarkets, as well as whether pricing differentials varied based on proximity between small stores and larger retailers. In 2014, prices were measured for 15 staple foods during store visits in 140 smaller stores (corner stores, gas-marts, dollar stores, and pharmacies) in Minneapolis/St. Paul, MN and their closest supermarket. Mixed models controlling for store type were used to estimate the average price differential between: (a) smaller stores and supermarkets; (b) isolated smaller stores (>1 mile to closest supermarket) and non-isolated smaller stores; and (c) isolated smaller stores inside versus outside USDA-identified food deserts. On average, all items except white bread were 10-54% more expensive in smaller stores than in supermarkets ( p Prices were generally not significantly different in isolated stores compared with non-isolated stores for most items. Among isolated stores, there were no price differences inside versus outside food deserts. We conclude that smaller food stores have higher prices for most staple foods compared to their closest supermarket, regardless of proximity. More research is needed to examine staple food prices in different retail spaces.

  2. Primary and repeated stapled hemorrhoidopexy for prolapsing hemorrhoids: Follow-up to five years

    DEFF Research Database (Denmark)

    Raahave, D.; Pedersen, I.K.; Jepsen, Lars Vedel

    2008-01-01

    Purpose: Treating hemorrhoids by stapled hemorrhoidopexy has become increasingly common, because the procedure results in less pain and allows the patient to return to work earlier than with open hemorrhoidectomy. However, the durability of stapled hemorrhoidopexy has not been evaluated. This study...

  3. Evaluation of stapled versus hand-sewn techniques for colo- rectal anastomosis after low anterior resection of mid-rectal carcinoma: a study on 50 patients.

    Science.gov (United States)

    Fayek, Ihab Samy

    2014-01-01

    To evaluate the outcome of stapled versus sutured colo-rectal anastomosis after low anterior resection of mid-rectal carcinoma. A prospective study of fifty patients who underwent colo-rectal anastomosis following low anterior resection (LAR) of T2 mid-rectal cancers at the Egyptian National Cancer Institute during the time period from June 2010 to June 2013 was conducted. Classification was into two groups; a stapled anastomosis group I (25 patients) and a hand-sewn anastomosis group II (25 patients). All operations are evaluated regarding intra-operative complications such as anastomotic line bleeding, visceral injuries or major blood loss. The anastomotic time and operative time are documented for each operation. All patients are evaluated post-operatively for anastomotic leakage (AL), wound infection and ileus. The distance of the tumor from the anal verge was 9.6 ± 2.0 cm in group I and 9.9 ± 2.4 cm in group II. The mean operative time was 191.5 ± 16.2 min in the stapled group and 208 ± 18.6 min in the sutured group (p=0.002). The mean anastomotic times were 9.0 ± 1.9 min and 19.7 ± 12.2 min (p=0.001). Anastomotic leakage developed in three (12.0%) patients in the stapled group and in four (16.0%) patients in the sutured group (p=1.000). Post-operative ileus was observed in 3 patients in group I and one patient in group II. Wound infection developed in three (12.0%) patients in the stapled group and four (16.0%) patients in the sutured group (p=1.000). Colo-rectal anastomosis after low anterior resection for mid rectal carcinoma can be conducted safely either by stapling or hand-sewn techniques; however the stapling technique showed shorter anastomotic and operative times with no significant advantages regarding intra- or post-operative complications or hospital stay.

  4. A randomized study comparing skin closure in cesarean sections: staples vs subcuticular sutures.

    Science.gov (United States)

    Rousseau, Julie-Anne; Girard, Karine; Turcot-Lemay, Lucile; Thomas, Nancy

    2009-03-01

    We sought to compare postoperative pain according to the skin closure method (subcuticular sutures vs staples) after an elective term cesarean section. A randomized controlled trial of 101 women was performed. Women were randomly assigned to subcuticular sutures or staples. Operative technique and postoperative analgesia were standardized. Stratification was used for primary vs repeat cesareans. Analog pain and satisfaction scales ranging from 0-10 were completed at postoperative days 1 and 3, and at 6 weeks postoperatively. A digital photograph of the incision was taken at 6 weeks postoperatively and evaluated by 3 independent blinded observers. Pain at 6 weeks postoperatively was significantly less in the staple group (0.17 vs 0.51; P = .04). Operative time was shorter in that group (24.6 vs 32.9 minutes; P women's satisfaction. Staples are the method of choice for skin closure for elective term cesareans in our population.

  5. [Staple fixation for the treatment of hamate metacarpal joint injury].

    Science.gov (United States)

    Tang, Yang-Hua; Zeng, Lin-Ru; Huang, Zhong-Ming; Yue, Zhen-Shuang; Xin, Da-Wei; Xu, Can-Da

    2014-03-01

    To investigate the effcacy of the staple fixation for the treatment of hamate metacarpal joint injury. From May 2009 to November 2012,16 patients with hamate metacarpal joint injury were treated with staple fixation including 10 males and 6 females with an average age of 33.6 years old ranging from 21 to 57 years. Among them, 11 cases were on the fourth or fifth metacarpal base dislocation without fractures, 5 cases were the fourth or fifth metacarpal base dislocation with avulsion fractures of the back of hamatum. Regular X-ray review was used to observe the fracture healing, joint replacement and position of staple fixation. The function of carpometacarpal joint and metacarpophalangeal joint were evaluated according to ASIA (TAM) system evaluation method. All incision were healed well with no infection. All patients were followed up from 16 to 24 months with an average of (10.0 +/- 2.7) months. No dislocation recurred, the position of internal fixator was good,no broken nail and screw withdrawal were occurred. Five patients with avulsion fracture of the back of hamatum achieved bone healing. The function of carpometacarpal joint and metacarpophalangeal was excellent in 10 cases,good in 5 cases, moderate in 1 case. The application of the staple for the treatment of hamatometacarpal joint injury has the advantages of simple operation, small trauma, reliable fixation, early postoperative function exercise and other advantages, which is the ideal operation mode for hamatometacarpal joint injury.

  6. Determination of withdrawal resistance of staple joints constructed with various members of upholstered furniture

    Directory of Open Access Journals (Sweden)

    saeid Kazemi Najafi

    2017-05-01

    Full Text Available The goal of this study was to investigate the effects of joints members type (oriented strand lumber, plywood and poplar wood (Populusdeltoides, penetration deeps of staple (12 and 17mm and adhesives (with and without adhesive on face and edge withdrawal resistance of joints fabricated with staple. Experimental specimens under withdrawal load test of face and edge consisted of two principal structural members, main member and a secondary member which were joined together by one staple. The results showed that joint member, penetration deeps and adhesive significantly influence on the withdrawal resistance. Staple withdrawal resistance in the face was higher than that in the edge. Staple holding resistance increased with the increase of penetration deep and the withdrawal resistance of joints fabricated by adhesive was higher than those without adhesive. The joints made by oriented strand lumber exhibited better performance than other two members and joints made with poplar wood had higher resistance than plywood joints. The highest face (2326N and edge (1265N withdrawal resistances were obtained from joints prepared from oriented strand lumber with adhesive and17mm penetration deeps.

  7. Long-term Evaluation of a Modified Double Staple Technique for Low Anterior Resection.

    Science.gov (United States)

    Illuminati, G; Carboni, F; Ceccanei, G; Pacilè, M A; Pizzardi, G; Palumbo, P; Vietri, F

    2014-01-01

    When performing low anterior resection for rectal cancer with the double staple technique, -closing the rectum with a linear stapler in the abdomen can be challenging, especially when dealing with a narrow pelvis. For such instances we proposed to modify this technique by pulling the rectal stump through the anus, doing an extra-anal resection of the tumor and linear suture of the rectal stump, before performing a standard, stapled colorectal anastomosis. The purpose of this study was to assess the adequacy of this modification of the double staple technique. Retrospective review of 108 patients undergoing a stapled, low colorectal or coloanal anastomosis, after -eversion, extra-anal resection of the tumor and linear closure of the rectal stump for colorectal cancer, from January 1990 to December 2012. Operative mortality was 0.9%. Fourteen patients (13%) presented early, surgery-related complications -consisting of 7 anastomotic leaks, 5 wound infections, 1 ureteral lesion, and 1 peristomal abscess. Late complications related to surgery included 5 incisional hernias (4.6%), 4 anastomotic strictures (3.7%), 4 neurogenic bladders (3.7%) and 2 fecal incontinences (1.8%). The incidence of local disease recurrence was 10%. Surgical and oncological results validate the proposed modification of the double staple technique, when facing difficulties in suturing the rectum from the abdomen. Copyright© Acta Chirurgica Belgica.

  8. Small intestinal volvulus caused by loose surgical staples.

    Science.gov (United States)

    Page, Matthew P; Kim, Heung Bae; Fishman, Steven J

    2009-09-01

    Small intestinal volvulus beyond infancy is rare and usually has an iatrogenic cause. The authors describe an adolescent boy with small bowel volvulus secondary to the presence of free intraperitoneal surgical staples after a laparoscopic appendectomy.

  9. A new mini-invasive technique in treating pediatric diaphyseal forearm fractures by bioabsorbable elastic stable intramedullary nailing: a preliminary technical report.

    Science.gov (United States)

    Sinikumpu, J-J; Keränen, J; Haltia, A-M; Serlo, W; Merikanto, J

    2013-01-01

    Operative treatment is often indicated in unstable pediatric diaphyseal forearm fractures. Recently minimally invasive reduction and elastic stable intramedullary nailing have been of increasing interest, instead of open reduction and internal fixation with plates. There are several disadvantages of metallic intramedullary implants, such as soft-tissue irritation and a risk of disturbing later imaging. Thus, they are generally removed in later operations. We aimed to develop a new technique to stabilize pediatric forearm fractures by the bioabsorbable intramedullary nailing. We developed a new, two-stage mini-invasive surgical technique to stabilize the unstable diaphyseal fractures in children. The procedure is bioabsorbable elastic stable intramedullary nailing. Ultra-high-strength bioabsorbable intramedullary nails of poly(lactide-co-glycolide) were manufactured for our purpose. The material has been widely proven to be biocompatible and stable enough for fracture treatment as screws and pins. We have used the new technique in the unstable both-bone diaphyseal forearm fractures in children between the ages of 5 and 15 years. We report the technique and our clinical experience in the series of those three cases that have been followed up for at least 12 months. The present series has been randomized for the procedure instead for titanium elastic stable intramedullary nailing, and the series represents a part of ongoing randomized trial. The reported cases operated by the new technique referred good union in the fractured bones and acceptable alignment in the follow-up. Removal of the implants was not required. No troubles with the procedure or implant per se were noticed, indicating good feasibility. One high-energy refracture occurred half year after the primary trauma. Traditional titanium implants were used to control the refracture. We report our preliminary experience of a new surgical mini-invasive procedure to stabilize the unstable pediatric forearm shaft

  10. Investigations on the Manufacturing and Mechanical Properties of Spun Yarns Made from Staple CF for Thermoset Composites

    Directory of Open Access Journals (Sweden)

    Hasan Mir Mohammad Badrul

    2017-12-01

    Full Text Available This article reports the results of investigations carried out to produce yarns consisting of staple carbon fiber (CF obtained from process waste for the manufacturing of composites suitable especially for thermoset applications. For this purpose, a comparative analysis is done on processability between 100% staple CF and 60 weight% staple CF mixed with 40 weight% PVA fibers in carding, drawing and spinning process. The hybrid yarns are produced by varying twist level. The PVA fibers of the hybrid yarn are then dissolved using hot water treatment. The mechanical properties of yarns consisting of 100% staple CF and hybrid yarns consisting of staple CF and PVA before and after hot water treatment are investigated. Furthermore, test specimen is also prepared by impregnating 100% staple CF yarn and the hybrid yarns (after the dissolving of PVA with epoxy resin. The results of the tensile test of the yarns in consolidated state reveals that the hybrid yarn produced with 80 T/m after hot water treatment exhibits approximately 75% of the tensile strength of virgin filament tow, and it is expected that the hybrid yarns can be applied for the manufacturing of thermoset based composites for load bearing structures.

  11. Laparoscopic intersphincteric resection for low rectal cancer: comparison of stapled and manual coloanal anastomosis.

    Science.gov (United States)

    Cong, J C; Chen, C S; Ma, M X; Xia, Z X; Liu, D S; Zhang, F Y

    2014-05-01

    The study aim was to analyse the safety and feasibility of laparoscopic intersphincteric resection with stapled coloanal anastomosis for low rectal cancer. Between March 2009 and August 2010, 22 patients underwent laparoscopic intersphincteric resection with a stapled coloanal anastomosis without a diverting ileostomy. The results were compared retrospectively with hand-sewn coloanal anastomoses performed between January 2001 and May 2009, which included 55 open and 38 laparoscopic intersphincteric resections. The morbidity comparison only included data relevant to the anastomosis. Function was compared using the Saito function questionnaire and the Wexner score and only involved data relevant to the laparoscopy. The anastomotic complication rates were similar for fistula, bleeding and neorectal mucosal prolapse (P = 0.526, P = 0.653 and P = 0.411, respectively). Anastomotic leakage and stricture formation of the stapled coloanal anastomosis were significantly lower than those of the hand-sewn coloanal anastomosis (P = 0.037 and P = 0.028, respectively). There were no significant differences in the Saito function questionnaire and the Wexner score between the stapled and hand-sewn coloanal anastomotic groups (all P > 0.05). Laparoscopic intersphincteric resection with a stapled coloanal anastomosis is technically feasible and is less likely to result in anastomotic leakage and stricture formation than a hand-sewn anastomosis. Colorectal Disease © 2014 The Association of Coloproctology of Great Britain and Ireland.

  12. Tailored Polyproteins Using Sequential Staple and Cut.

    Science.gov (United States)

    Garg, Surbhi; Singaraju, Gayathri Sindhuri; Yengkhom, Sunanda; Rakshit, Sabyasachi

    2018-04-30

    Polyproteins, individual protein units joined covalently in tandem, have evolved as a promising tool for measuring the dynamic folding of biomacromolecules in single-molecule force spectroscopy. However, the synthetic routes to prepare polyproteins have been a bottleneck, and urge development of in vitro methods to knit individual protein units covalently into polyprotein. Employing two enzymes of orthogonal functionalities periodically in sequence, we synthesized monodispersed polyproteins on a solid surface. We used Sortase A (SrtA), the enzyme known for sequence specific transpeptidation, to staple protein units covalently through peptide bonds. Exploiting the sequence-specific peptide cleaving ability of TEV protease, we controlled the progress of the reaction to one attachment at a time. Finally, with unique design of the unit proteins we control the orientation of proteins in polyprotein. This simple conjugation has the potential to staple proteins with different functionalities and from different expression systems, in any number in the polyprotein and, above all, via irreversible peptide bonds. Multiple chimeric constructs can also be synthesized with interchangeable protein units.

  13. "Dog ear" formation after double-stapled low anterior resection as a risk factor for anastomotic disruption.

    Science.gov (United States)

    Roumen, R M; Rahusen, F T; Wijnen, M H; Croiset van Uchelen, F A

    2000-04-01

    The aim of this study was to investigate the possible deleterious effect of the lateral intersecting margins (so-called dog ears) on anastomotic disruption after experimentally performed double-stapled anastomoses. Two groups of double-stapled side-to-end anastomoses were performed using pig small intestines. Group A consisted of 35 circular anastomoses and Group B of 32 double-stapled anastomoses with a bilateral dog ear. In both groups bursting pressures were tested using a water-filled, pressure-controlled automatic pumping system (Hamou Endomat), and special attention was paid to the location(s) in the anastomoses were the disruption(s) occurred. In Group A bursting pressures were significantly higher than in Group B (median pressure, 90 vs. 60 mmHg; P dog ear. We conclude that the lateral intersections of double-stapled anastomoses are a structural weak spot and that the currently most often applied double-stapled anastomosis is a less effective type of anastomosis than a complete circular one. Resolving this technical problem might help to reduce the number of anastomotic disruptions after low anterior resections.

  14. Long-term outcome of stapled transanal rectal resection (STARR) versus stapled hemorrhoidopexys (STH) for grade III-IV hemorrhoids: preliminary results.

    Science.gov (United States)

    Zanella, Simone; Spirch, Saverio; Scarpa, Marco; Ricci, Francesco; Lumachi, Franco

    2014-01-01

    Circular stapled transanal hemorrhoidopexy (STH) was first introduced by A. Longo for the correction of internal mucosal prolapse and obstructed defecation and in 1998, was proposed as alternative to conventional excisional hemorrhoidectomy. More recently, stapled transanal rectal resection (STARR) has gradually gained popularity, as the Longo procedure, in the treatment of hemorrhoids. The aim of our study was to evaluate the usefulness of STARR as alternative to STH in patients with grade III (n=218, 68.1%) and IV (n=102, 31.9%) hemorrhoids. A group of 320 consecutive patients (median age=51 years; range=16-85) underwent STH (n=281) or STARR (n=39) procedure. The rate of postoperative bleeding (53.8% vs. 74.4%, phemorrhoids and a lower incidence of prolapse, both at one year (none vs. 1.4%, p=0.593 and 2.6% vs. 5.3%, p=0.396, respectively) and at two years (none vs. 6.8%, p=0.078 and none vs. 13.2%, p=0.012, respectively). The one-year (9.0 ± 1.8 vs. 9.4 ± 0.7, p=0.171) and two-year (9.6 ± 0.8 vs. 9.1 ± 1.7, p=0.072) general satisfaction was similar but higher in STARR patients than in the STH group. In conclusion, according to our preliminary results, the STARR procedure leads to a lower incidence of complications and recurrences and should be considered for patients with grade III or IV hemorrhoids previously selected for stapled hemorrhoidectomy, as a promising alternative to STH. Copyright © 2014 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.

  15. Stapled versus hand-sewn cervical esophagogastric anastomosis in patients undergoing esophagectomy: A Retrospective Cohort Study

    Science.gov (United States)

    Mishra, Pramod Kumar; Shah, Harsh; Gupta, Nikhil; Varshney, Vaibhav; Patil, Nilesh Sadashiv; Jain, Amit; Saluja, Sundeep Singh

    2016-01-01

    Introduction Anastomotic leak is one of the main causes of morbidity following esophageal resection for carcinoma of the esophagus and gastroesophageal junction. We compared hand sewn and stapled cervical esophagogastric anastomotic techniques in terms of postoperative complications. Methods All patients who underwent esophagectomy with cervical esophagogastric anastomosis at a single academic center from 2004 to 2014 were included in the study. Both early and late complications were analyzed. Results 153 patients underwent resection for carcinoma of the esophagus and gastroesophageal junction. Of these 140 patients had esophagectomy with cervical esophagogastric anastomosis. 66 patients underwent a hand sewn anastomosis and 74 patients had a side-to-side stapled anastomosis fashioned. Both groups were comparable with respect to preoperative characteristics. There was no difference in the operative blood loss and T and N stage of the disease. The overall morbidity and mortality was 32.8% and 6.4%, respectively. Overall leak rate was 17%. There was no difference in the leak rates among two groups (12 in the hand-sewn group & 12 in the Stapled stapled group; p = 0.82). The rate of anastomotic stricture was significantly higher for the hand sewn group (16.1% vs 4.3%; p = 0.03) at median follow up of 30 months. Conclusion Both hand sewn and stapled anastomotic techniques are equally effective way of performing a cervical esophagogastric anastomosis. However, patients having anastomotic leak develop anastomotic stricture more often in those having hand-sewn anastomosis compared to stapled anastomosis. PMID:27222711

  16. Complications Using Bioabsorbable Cross-Pin Femoral Fixation: A Case Report and Review of the Literature

    Directory of Open Access Journals (Sweden)

    Saqib Hasan

    2011-01-01

    Full Text Available The use of bioabsorbable cross-pin transcondylar fixation has remained a viable option for femoral fixation in anterior cruciate ligament reconstruction. Although numerous biomechanical studies have demonstrated high fixation strength and minimal slippage with use of this method of fixation, there have been increasing reports of a variety of clinical complications associated with these implants. We reviewed the literature for all complications associated with the Bio-TransFix implant and present a case report of a patient status after ACL reconstruction using Bio-TransFix cross-pin femoral fixation with iliotibial band friction syndrome from a broken cross-pin four month post-operatively.

  17. Glued versus stapled anastomosis of the colon: An experimental study to determine comparative resistance to intraluminal pressure

    Directory of Open Access Journals (Sweden)

    Jiri Paral

    2014-07-01

    Conclusion: Healing with absorbable synthetic glue was as good as with staples. Glued anastomoses resisted pressures that were statistically significantly higher than physiological intraluminal colon pressures but lower than stapled ones.

  18. Evaluation of a Bioabsorbable Self-Expandable Vein Stent-Base Made of Poly(l-lactide) In Vitro and In Vivo

    Energy Technology Data Exchange (ETDEWEB)

    Løvdal, Alexandra Liv Vest, E-mail: alvlo@nanotech.dtu.dk [Technical University of Denmark, Department of Micro- and Nanotechnology (Denmark); Calve, Sarah [Purdue University, Weldon School of Biomedical Engineering (United States); Yang, Shuo; Alstine, William Van [Cook Research Incorporated (United States); Binkert, Christoph A. [Institut für Radiologie, Kantonsspital Winterthur (Switzerland); Klausen, Kasper [William Cook Europe (Denmark)

    2017-01-15

    PurposeThis study was designed to evaluate performance and tissue response to a self-expandable bioabsorbable vein stent-base cut from a tube with enhanced stiffness and strength in vitro and in vivo.MethodsA diamond-shaped stent-base was cut from a sequential biaxially strained poly(l-lactide) (PLLA) tube for optimized performance. The performance of the stent-base was evaluated in a finite element analysis model, and validation was attempted in vitro through a cyclic flat-plate compression and radial force measurement. The performance of the stent-base was tested in vivo using 3 sheep with 2 implants each for 2 and 3½ weeks, respectively.ResultsIn vitro the stent-base showed an elliptical deformation but no fractures. In vivo the stent-base showed adequate radial force and no migration. All implanted stent-bases showed multiple fractures not only at the predicted stress zones but at all connecting points. Fragments of the caudal stent-base stayed in the vein wall indicating sufficient tissue coverage to avoid embolization of the fractured stent pieces, whereas fragments from the cranial device remaining were few. Neointima formation was confirmed histologically at 2 and 3½ weeks.ConclusionA bioabsorbable self-expandable stent-base made from PLLA for large veins seems feasible, but over time, the PLLA used in this study appears too stiff and lacks the sufficient flexibility to move with the vena cava, causing multiple fractures.

  19. Evaluation of a Bioabsorbable Self-Expandable Vein Stent-Base Made of Poly(L-lactide) In Vitro and In Vivo.

    Science.gov (United States)

    Løvdal, Alexandra Liv Vest; Calve, Sarah; Yang, Shuo; Van Alstine, William; Binkert, Christoph A; Klausen, Kasper

    2017-01-01

    This study was designed to evaluate performance and tissue response to a self-expandable bioabsorbable vein stent-base cut from a tube with enhanced stiffness and strength in vitro and in vivo. A diamond-shaped stent-base was cut from a sequential biaxially strained poly(L-lactide) (PLLA) tube for optimized performance. The performance of the stent-base was evaluated in a finite element analysis model, and validation was attempted in vitro through a cyclic flat-plate compression and radial force measurement. The performance of the stent-base was tested in vivo using 3 sheep with 2 implants each for 2 and 3½ weeks, respectively. In vitro the stent-base showed an elliptical deformation but no fractures. In vivo the stent-base showed adequate radial force and no migration. All implanted stent-bases showed multiple fractures not only at the predicted stress zones but at all connecting points. Fragments of the caudal stent-base stayed in the vein wall indicating sufficient tissue coverage to avoid embolization of the fractured stent pieces, whereas fragments from the cranial device remaining were few. Neointima formation was confirmed histologically at 2 and 3½ weeks. A bioabsorbable self-expandable stent-base made from PLLA for large veins seems feasible, but over time, the PLLA used in this study appears too stiff and lacks the sufficient flexibility to move with the vena cava, causing multiple fractures.

  20. Evaluation of a Bioabsorbable Self-Expandable Vein Stent-Base Made of Poly(l-lactide) In Vitro and In Vivo

    International Nuclear Information System (INIS)

    Løvdal, Alexandra Liv Vest; Calve, Sarah; Yang, Shuo; Alstine, William Van; Binkert, Christoph A.; Klausen, Kasper

    2017-01-01

    PurposeThis study was designed to evaluate performance and tissue response to a self-expandable bioabsorbable vein stent-base cut from a tube with enhanced stiffness and strength in vitro and in vivo.MethodsA diamond-shaped stent-base was cut from a sequential biaxially strained poly(l-lactide) (PLLA) tube for optimized performance. The performance of the stent-base was evaluated in a finite element analysis model, and validation was attempted in vitro through a cyclic flat-plate compression and radial force measurement. The performance of the stent-base was tested in vivo using 3 sheep with 2 implants each for 2 and 3½ weeks, respectively.ResultsIn vitro the stent-base showed an elliptical deformation but no fractures. In vivo the stent-base showed adequate radial force and no migration. All implanted stent-bases showed multiple fractures not only at the predicted stress zones but at all connecting points. Fragments of the caudal stent-base stayed in the vein wall indicating sufficient tissue coverage to avoid embolization of the fractured stent pieces, whereas fragments from the cranial device remaining were few. Neointima formation was confirmed histologically at 2 and 3½ weeks.ConclusionA bioabsorbable self-expandable stent-base made from PLLA for large veins seems feasible, but over time, the PLLA used in this study appears too stiff and lacks the sufficient flexibility to move with the vena cava, causing multiple fractures.

  1. Comparison of stapled haemorrhoidopexy with traditional excisional surgery for haemorrhoidal disease (eTHoS): a pragmatic, multicentre, randomised controlled trial.

    Science.gov (United States)

    Watson, Angus J M; Hudson, Jemma; Wood, Jessica; Kilonzo, Mary; Brown, Steven R; McDonald, Alison; Norrie, John; Bruhn, Hanne; Cook, Jonathan A

    2016-11-12

    Two commonly performed surgical interventions are available for severe (grade II-IV) haemorrhoids; traditional excisional surgery and stapled haemorrhoidopexy. Uncertainty exists as to which is most effective. The eTHoS trial was designed to establish the clinical effectiveness and cost-effectiveness of stapled haemorrhoidopexy compared with traditional excisional surgery. The eTHoS trial was a large, open-label, multicentre, parallel-group, pragmatic randomised controlled trial done in adult participants (aged 18 years or older) referred to hospital for surgical treatment for grade II-IV haemorrhoids. Participants were randomly assigned (1:1) to receive either traditional excisional surgery or stapled haemorrhoidopexy. Randomisation was minimised according to baseline EuroQol 5 dimensions 3 level score (EQ-5D-3L), haemorrhoid grade, sex, and centre with an automated system to stapled haemorrhoidopexy or traditional excisional surgery. The primary outcome was area under the quality of life curve (AUC) measured with the EQ-5D-3L descriptive system over 24 months, assessed according to the randomised groups. The primary outcome measure was analysed using linear regression with adjustment for the minimisation variables. This trial is registered with the ISRCTN registry, number ISRCTN80061723. Between Jan 13, 2011, and Aug 1, 2014, 777 patients were randomised (389 to receive stapled haemorrhoidopexy and 388 to receive traditional excisional surgery). Stapled haemorrhoidopexy was less painful than traditional excisional surgery in the short term and surgical complication rates were similar between groups. The EQ-5D-3L AUC score was higher in the traditional excisional surgery group than the stapled haemorrhoidopexy group over 24 months; mean difference -0·073 (95% CI -0·140 to -0·006; p=0·0342). EQ-5D-3L was higher for stapled haemorrhoidopexy in the first 6 weeks after surgery, the traditional excisional surgery group had significantly better quality of life

  2. A randomized study comparing outcomes of stapled and hand-sutured anastomoses in patients undergoing open gastrointestinal surgery.

    Science.gov (United States)

    Chandramohan, S M; Gajbhiye, Raj Narenda; Agwarwal, Anil; Creedon, Erin; Schwiers, Michael L; Waggoner, Jason R; Tatla, Daljit

    2013-08-01

    Although stapling is an alternative to hand-suturing in gastrointestinal surgery, recent trials specifically designed to evaluate differences between the two in surgery time, anastomosis time, and return to bowel activity are lacking. This trial compared the outcomes of the two in subjects undergoing open gastrointestinal surgery. Adult subjects undergoing emergency or elective surgery requiring a single gastric, small, or large bowel anastomosis were enrolled into this open-label, prospective, randomized, interventional, parallel, multicenter, controlled trial. Randomization was assigned in a 1:1 ratio between the hand-sutured group (n = 138) and the stapled group (n = 142). Anastomosis time, surgery time, and time to bowel activity were collected and compared as primary endpoints. A total of 280 subjects were enrolled from April 2009 to September 2010. Only the time of anastomosis was significantly different between the two arms: 17.6 ± 1.90 min (stapled) and 20.6 ± 1.90 min (hand-sutured). This difference was deemed not clinically or economically meaningful. Safety outcomes and other secondary endpoints were similar between the two arms. Mechanical stapling is faster than hand-suturing for the construction of gastrointestinal anastomoses. Apart from this, stapling and hand-suturing are similar with respect to the outcomes measured in this trial.

  3. Staple Food Self-Sufficiency of Farmers Household Level in The Great Solo

    Science.gov (United States)

    Darsono

    2017-04-01

    Analysis of food security level of household is a novelty of measurement standards which usually includes regional and national levels. With household approach is expected to provide the basis of sharp food policy formulation. The purpose of this study are to identify the condition of self-sufficiency in staple foods, and to find the main factors affecting the dynamics of self-sufficiency in staple foods on farm household level in Great Solo. Using primary data from 50 farmers in the sample and secondary data in Great Solo (Surakarta city, Boyolali, Sukoharjo, Karanganyar, Wonogiri, Sragen and Klaten). Compiled panel data were analyzed with linear probability regression models to produce a good model. The results showed that farm households in Great Solo has a surplus of staple food (rice) with an average consumption rate of 96.8 kg/capita/year. This number is lower than the national rate of 136.7 kg/capita/year. The main factors affecting the level of food self-sufficiency in the farmer household level are: rice production, rice consumption, land tenure, and number of family members. Key recommendations from this study are; improvement scale of the land cultivation for rice farming and non-rice diversification consumption.

  4. 26 CFR 1.269B-1 - Stapled foreign corporations.

    Science.gov (United States)

    2010-04-01

    ... avoidance of U.S. income tax. A stapling of interests may have a principal purpose of tax avoidance even though the tax avoidance purpose is outweighed by other purposes when taken together. (3) Example. The....269B-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX...

  5. Endoscopic management of anastomotic bleeding in the ileal pouch with staples removal and clipping

    Directory of Open Access Journals (Sweden)

    Xian-rui Wu

    2013-01-01

    Full Text Available Objective: Postoperative pouch bleeding is a rare but detrimental complication following ileal pouch surgery. It is usually self-limited, however continuous bleeding requires inter- vention. There is limited published data on its management. Design: Ileoscopy via stoma for loop ileostomy and pouchoscopy via anus for ileal pouch were performed under sedation for the purpose of diagnosis and management of postop- erative bleeding. Results: Ileoscopy demonstrated a large, long blood clot in the lumen of efferent limb, but no sign of active bleeding was identified. Pouchoscopy showed that lumen of pouch body as well as afferent limb was filled with maroon-colored liquid stool. Pouch and neo-terminal ileum mucosa was normal. Two dislodged staples at the anastomotic line with sharp tips towards the lumen were found, with activating bleeding at one site. The staples were re- moved by biopsy forceps, and active bleeding was successfully controlled by the deploy- ment of one endoclip. Conclusions: We reported the first case that postoperative pouch bleeding, which was caused by dislodged staples, was successfully managed by endoscopic removal of the staples com- bined with clipping. Resumo: Objetivo: O sangramento pós-operatório da bolsa ileal é uma complicação rara, mas prejudi- cial após abordagem cirúrgica da bolsa ileal. Esse sangramento é geralmente autolimitado, porém, requer intervenção quando contínuo. Não há dados publicados sobre o tratamento. Método: Ileoscopia através de estoma para ileostomia em alça e endoscopia via ânus para a bolsa ileal foram realizadas sob sedação para diagnóstico e tratamento do sangramento pós-operatório. Resultados: A ileoscopia demonstrou um grande e longo coágulo sanguíneo no lúmen do ramo eferente, mas nenhum sinal de sangramento ativo foi identificado. A endoscopia da bolsa ileal mostrou que os lumens do corpo da bolsa e ramo aferente estavam cheios de fe- zes líquidas de cor marrom. A

  6. Long-term prospective evaluation of intestinal anastomosis using stainless steel staples in 14 dogs.

    Science.gov (United States)

    Benlloch-Gonzalez, Manuel; Gomes, Eymeric; Bouvy, Bernard; Poncet, Cyrill

    2015-07-01

    This prospective clinical study evaluated the use, complications, and clinical and ultrasonographic follow-ups of end-to-end intestinal anastomoses with skin staples in naturally occurring diseases in canine small and large intestines. Intestinal anastomoses were performed in 14 dogs and pre-, peri-, and postoperative data were recorded. Postoperative clinical and ultrasound evaluations were performed at regular intervals for 1 year. The mean time taken to construct the anastomosis was 5 min. There were no intraoperative complications. Hemorrhage and colonic stricture were the main postoperative complications. Staple loss occurred in 2 cases. Absence of wall layering and focal wall thickening were observed in all cases at each ultrasonographic follow-up. Hyperechoic fat was observed in all but 1 of the cases at month 1. Nine dogs were alive with normal digestive function at the end of the study. The skin stapler technique enabled rapid construction of consistent anastomoses with inexpensive stapling material.

  7. Mineral Elements Content of some Coarse Grains used as staple ...

    African Journals Online (AJOL)

    Analysis of mineral elements were carried out on some coarse grains used as staple food in Kano metropolis. The levels of Magnesium, Calcium, Manganese, Iron, Copper and Zinc were determined using atomic absorption spectrophotometer (AAS), and that of Sodium and Potassium were obtained using flame photometer ...

  8. The STAPL Parallel Graph Library

    KAUST Repository

    Harshvardhan,

    2013-01-01

    This paper describes the stapl Parallel Graph Library, a high-level framework that abstracts the user from data-distribution and parallelism details and allows them to concentrate on parallel graph algorithm development. It includes a customizable distributed graph container and a collection of commonly used parallel graph algorithms. The library introduces pGraph pViews that separate algorithm design from the container implementation. It supports three graph processing algorithmic paradigms, level-synchronous, asynchronous and coarse-grained, and provides common graph algorithms based on them. Experimental results demonstrate improved scalability in performance and data size over existing graph libraries on more than 16,000 cores and on internet-scale graphs containing over 16 billion vertices and 250 billion edges. © Springer-Verlag Berlin Heidelberg 2013.

  9. Development of Flame Resistant Combat Uniform Fabrics Made from Long Staple Wool and Aramid Blend Yarn

    Science.gov (United States)

    2013-04-15

    Kentwool recombed the wool top ( wool is first combed during the production of wool top); a second combing process is an optional step sometimes used in...RESISTANT COMBAT UNIFORM FABRICS MADE FROM LONG STAPLE WOOL AND ARAMID BLEND YARN by Parvez Mehta* Mitchell Driggers* and Carole...SUBTITLE DEVELOPMENT OF FLAME RESISTANT COMBAT UNIFORM FABRICS MADE FROM LONG STAPLE WOOL AND ARAMID BLEND YARN 5a. CONTRACT NUMBER W911QY-11

  10. A powered vascular staple for the application of segmental bronchial closure in thoracoscopic anatomic segmentectomy.

    Science.gov (United States)

    Kuroda, Hiroaki; Yoshida, Tatsuya; Sakao, Yukinori

    2017-12-01

    We used the powered vascular staple (PVS) instead of the conventional staple technique [the utilization of the powered linier cutter (PLC)] or ligation for total 23 segmental or subsegmental bronchi with less than 10 mm in the bronchial luminal size on computed tomography (CT) in thoracoscopic segmentectomy. Our results suggested that the availability of the PVS represents a novel advance in the armamentarium and may have a possibility of being pervasive widely however, more observative periods and further sample accumulation are needed.

  11. Staple Food and Livestock Production among the Yoruba of the ...

    African Journals Online (AJOL)

    Toshiba

    natural for a staple food farmer to also, essentially, own and raise livestock. No doubt .... whole, by 1945, agriculture in Ekiti had generally experienced ... fried plantain or processed dried powdered plantain, in form of amala .... There were, however, some dangers to livestock production in the ... goats, sheep, dogs and pigs.

  12. The stapl Skeleton Framework

    KAUST Repository

    Zandifar, Mani

    2015-01-01

    © Springer International Publishing Switzerland 2015. This paper describes the stapl Skeleton Framework, a highlevel skeletal approach for parallel programming. This framework abstracts the underlying details of data distribution and parallelism from programmers and enables them to express parallel programs as a composition of existing elementary skeletons such as map, map-reduce, scan, zip, butterfly, allreduce, alltoall and user-defined custom skeletons. Skeletons in this framework are defined as parametric data flow graphs, and their compositions are defined in terms of data flow graph compositions. Defining the composition in this manner allows dependencies between skeletons to be defined in terms of point-to-point dependencies, avoiding unnecessary global synchronizations. To show the ease of composability and expressivity, we implemented the NAS Integer Sort (IS) and Embarrassingly Parallel (EP) benchmarks using skeletons and demonstrate comparable performance to the hand-optimized reference implementations. To demonstrate scalable performance, we show a transformation which enables applications written in terms of skeletons to run on more than 100,000 cores.

  13. LONG TERM RESULTS AFTER STAPLED HEMORRHOIDOPEXY ALONE AND COMPLEMENTED BY EXCISIONAL HEMORRHOIDECTOMY: A RETROSPECTIVE COHORT STUDY.

    Science.gov (United States)

    Araujo, Sergio Eduardo Alonso; Horcel, Lucas de Araujo; Seid, Victor Edmond; Bertoncini, Alexandre Bruno; Klajner, Sidney

    2016-01-01

    Stapled hemorrhoidopexy is associated with less postoperative pain and faster recovery. However, it may be associated with a greater risk of symptomatic recurrence. We hypothesized that undertaking a limited surgical excision of hemorrhoid disease after stapling may be a valid approach for selected patients. To compare long-term results after stapled hemorrhoidopexy with and without complementation with closed excisional technique. In a retrospective uni-institutional cohort study, sixty-five (29 men) patients underwent stapled hemorrhoidopexy and 21 (13 men) underwent stapled hemorrhoidopexy with excision. The same surgeons operated on all cases. Patients underwent stapled hemorrhoidectomy associated with excisional surgery if symptoms attributable to external hemorrhoid piles were observed preoperatively, or if residual prolapse or bulky external disease was observed after the firing of the stapler. A closed excisional diathermy hemorrhoidectomy without vascular ligation was utilized in all complemented cases. All clinical variables were obtained from a questionnaire evaluation obtained through e-mail, telephone interview, or office follow-up. The median duration of postoperative follow-up was 48.5 (6-40) months. Patients with grades 3 and 4 hemorrhoid disease were operated on more frequently using stapled hemorrhoidopexy complemented with excisional technique (95.2% vs. 55.4%, p=0.001). Regarding respectively stapled hemorrhoidopexy and stapled hemorrhoidopexy complemented with excision, there was no difference between the techniques in relation to symptom recurrence (43% and 33%, p=0.45) and median interval between surgery and symptom recurrence (30 (8-84) and 38.8 (8-65) months, p=0.80). Eight (12.3%) patients were re-operated after stapled hemorrhoidopexy and 2 (9.6%), after hemorrhoidopexy with excision (p=0.78). Patient distribution in both groups according to the degree of postoperative satisfaction was similar (p=0.97). Stapled hemorrhoidopexy combined

  14. Evaluation of a Bioabsorbable Self-Expandable Vein Stent-Base Made of Poly(L-lactide) In Vitro and In Vivo

    DEFF Research Database (Denmark)

    Løvdal, Alexandra Liv Vest; Calve, Sarah; Yang, Shuo

    2017-01-01

    implants each for 2 and 3½ weeks, respectively. Results  In vitro the stent-base showed an elliptical deformation but no fractures. In vivo the stent-base showed adequate radial force and no migration. All implanted stent-bases showed multiple fractures not only at the predicted stress zones but at all......  A bioabsorbable self-expandable stent-base made from PLLA for large veins seems feasible, but over time, the PLLA used in this study appears too stiff and lacks the sufficient flexibility to move with the vena cava, causing multiple fractures....

  15. Comparison of Acute Thrombogenicity for Metallic and Polymeric Bioabsorbable Scaffolds: Magmaris Versus Absorb in a Porcine Arteriovenous Shunt Model.

    Science.gov (United States)

    Waksman, Ron; Lipinski, Michael J; Acampado, Eduardo; Cheng, Qi; Adams, Lila; Torii, Sho; Gai, Jiaxiang; Torguson, Rebecca; Hellinga, David M; Westman, Peter C; Joner, Michael; Zumstein, Philine; Kolodgie, Frank D; Virmani, Renu

    2017-08-01

    A comparison in acute thrombogenicity between the Magmaris sirolimus-eluting bioabsorbable magnesium scaffold and the Absorb bioresorbable vascular scaffold has not been performed. This study assessed acute thrombogenicity of Magmaris compared with Absorb and the Orsiro hybrid drug-eluting stent in a porcine arteriovenous shunt model. An ex vivo porcine carotid jugular arteriovenous shunt was established and connected to SYLGARD tubing containing the Magmaris, Absorb, and Orsiro scaffolds/stents and allowed to run in the shunt for a maximum of 1 hour. Twelve shunts (2 shunt runs per pig) were run comparing the 3 scaffolds in alternating order. Nested generalized linear mixed models were used to compare variables between scaffold groups while adjusting for variability between shunt runs. Confocal fluorescent microscopy costaining CD61/CD42b demonstrated that both Magmaris (3.0%) and Orsiro (4.6%) had less platelet coverage of the total scaffold compared with Absorb (21.8%). Scanning electron microscopy demonstrated significantly less thrombus deposition to Magmaris as a percentage of the total scaffold compared with Absorb (5.0% versus 16.1%, P =0.02). Magmaris had significantly less PM-1-positive neutrophil and CD14-positive monocyte adherence compared with both Orsiro and Absorb. Orsiro had significantly less monocyte deposition compared with Absorb. Despite a similar scaffold strut thickness, the Magmaris sirolimus-eluting bioabsorbable magnesium scaffold was significantly less thrombogenic compared with the Absorb bioresorbable vascular scaffold in an ex vivo porcine arteriovenous shunt model. Further studies are needed to determine whether the reduced thrombogenicity of Magmaris will result in reductions in major cardiovascular events. © 2017 American Heart Association, Inc.

  16. A Cautionary Analysis of STAPLE Using Direct Inference of Segmentation Truth

    DEFF Research Database (Denmark)

    Van Leemput, Koen; Sabuncu, Mert R.

    2014-01-01

    In this paper we analyze the properties of the well-known segmentation fusion algorithm STAPLE, using a novel inference technique that analytically marginalizes out all model parameters. We demonstrate both theoretically and empirically that when the number of raters is large, or when consensus r...

  17. Neuron attachment properties of carbon negative-ion implanted bioabsorbable polymer of poly-lactic acid

    International Nuclear Information System (INIS)

    Tsuji, Hiroshi; Sasaki, Hitoshi; Sato, Hiroko; Gotoh, Yasuhito; Ishikawa, Junzo

    2002-01-01

    Modification of a bioabsorbable polymer of poly-lactic acid (PLA) by negative carbon ion implantation was investigated with resect to radiation effects on surface physical properties and nerve-cell attachment properties. Carbon negative ions were implanted to PLA at energy of 5-30 keV with a dose of 10 14 -10 16 ions/cm 2 . Most C-implanted PLA samples showed contact angles near 80 deg. and almost same as that of unimplanted PLA, although a few samples at 5 keV and less 3x10 14 ions/cm 2 had contact angles larger than 90 deg. The attachment properties of nerve cells of PC-12h (rat adrenal phechromocytoma) in vitro were studied. PC-12h cells attached on the unimplanted region in C-implanted PLA samples at 5 and 10 keV. On the contrary, the nerve cells attached on only implanted region for the C-implanted PLA sample at 30 keV and 1x10 15 ions/cm 2

  18. Staple fixation for akin proximal phalangeal osteotomy in the treatment of hallux valgus interphalangeus.

    Science.gov (United States)

    Neumann, Julie A; Reay, Kathleen D; Bradley, Kendall E; Parekh, Selene G

    2015-04-01

    The Akin proximal phalangeal osteotomy is commonly used in conjunction with metatarsal osteotomies to treat hallux valgus. Multiple fixation methods including suture, wire, screw, and staple fixation have been described. The aims of this study were to assess the intraoperative and postoperative complications and to evaluate short-term postoperative outcomes in patients who underwent Akin osteotomy with staple fixation. Forty-four patients (51 feet) with painful hallux valgus were retrospectively reviewed at an average of 40.4 ± 15.8 (range, 25.9 to 79.9) weeks following an Akin osteotomy with staple fixation. Patient reported preoperative and postoperative Visual Analog Score (VAS) (0 to 10, 0 = no pain) was recorded. Level of activity was reported postoperatively. Hallux valgus angles (HVAs), intermetatarsal angles (IMAs), and hallux valgus interphalangeus angles (IPAs) were evaluated on preoperative as well as final postoperative radiographs. Postoperative clinical and radiographic examinations were used to evaluate for complications. Mean VAS improved from 4.4 ± 2.6 to 1.0 ± 1.2 (P hallux valgus correction with improvement in pain and hallux valgus deformity with a low risk for complications. Level IV, case series. © The Author(s) 2014.

  19. Trace Metal Levels in Raw and Heat Processed Nigerian Staple ...

    African Journals Online (AJOL)

    The levels of some trace metals (Fe, Zn, Cu, Ni, Cd) were quantitatively determined in raw and heat processed staple food cultivars (yam, cassava, cocoyam and maize) from oil producing areas of part of the Niger Delta and compared with a non-oil producing area of Ebonyi State as control. The survey was conducted to ...

  20. Heat adaptation of bioabsorbable craniofacial plates: a critical review of science and technology.

    Science.gov (United States)

    Pietrzak, William S

    2009-11-01

    Bioabsorbable fixation plates often require adaptation to the bone. This is typically accomplished by heating the plates to above the glass transition temperature and placing the softened plates against the bone or a prebent template until cool. Upon cooling, the plates regain stiffness and can be attached to bone to obtain anatomic fixation. This procedure is both efficient and effective and has been used throughout the craniofacial skeleton. There are many types of equipment available to heat the plates, each with advantages and disadvantages. Although a conceptually simple process, there are several nuances that have been reported in the literature, including transient effects on plate mechanical properties, memory effects, differences between wet and dry heating, and others. Upon the backdrop of the overwhelming clinical success of heat adaptation, this review critically evaluates the method and provides a comprehensive examination and explanation of the basic science and technology involved. This should help give surgeons a better understanding of the process that can help improve their use and further advance the technology.

  1. Modality of wound closure after total knee replacement: are staples as safe as sutures? A retrospective study of 181 patients

    Directory of Open Access Journals (Sweden)

    Hammerberg E Mark

    2011-10-01

    Full Text Available Abstract Background Surgical site wound closure plays a vital role in post-operative success. This effect is magnified in regard to commonly performed elective procedures such as total knee arthroplasty. The use of either sutures or staples for skin re-approximation remains a contested subject, which may have a significant impact on both patient safety and surgical outcome. The literature remains divided on this topic. Methods Two cohorts of patients at a level one trauma and regional referral center were reviewed. Cohorts consisted of consecutive total knee arthroplasties performed by two surgeons who achieved surgical wound re-approximation by either staples or absorbable subcuticular sutures. Outcome variables included time of surgery, wound dehiscence, surgical site infection per Center for Disease Control criteria and repeat procedures for debridement and re-closure. Results 181 patients qualified for study inclusion. Staples were employed in 82 cases (45.3% of total and sutures in 99 cases (54.7%. The staples group had no complications while the sutures group had 9 (9.1%. These consisted of: 4 infections (2 superficial, one deep, one organ/space; three patients required re-suturing for dehiscence; one allergic type reaction to suture material; and one gout flare resulting in dehiscence. The mean surgical time with sutures was 122.3 minutes (sd = 33.4 and with staples was 114 minutes (sd = 24.4. Conclusion This study demonstrated significantly fewer complications with staple use than with suture use. While all complications found in this study cannot be directly attributed to skin re-approximation method, the need for further prospective, randomized trials is established.

  2. Stapled transanal rectal resection in solitary rectal ulcer associated with prolapse of the rectum: a prospective study.

    Science.gov (United States)

    Boccasanta, Paolo; Venturi, Marco; Calabro, Giuseppe; Maciocco, Marco; Roviaro, Gian Carlo

    2008-03-01

    At present, none of the conventional surgical treatments of solitary rectal ulcer associated with internal rectal prolapse seems to be satisfactory because of the high incidence of recurrence. The stapled transanal rectal resection has been demonstrated to successfully cure patients with internal rectal prolapse associated with rectocele, or prolapsed hemorrhoids. This prospective study was designed to evaluate the short-term and long-term results of stapled transanal rectal resection in patients affected by solitary rectal ulcer associated with internal rectal prolapse and nonresponders to biofeedback therapy. Fourteen patients were selected on the basis of validated constipation and continence scorings, clinical examination, anorectal manometry, defecography, and colonoscopy and were submitted to biofeedback therapy. Ten nonresponders were operated on and followed up with incidence of failure, defined as no improvement of symptoms and/or recurrence of rectal ulceration, as the primary outcome measure. Operative time, hospital stay, postoperative pain, time to return to normal activity, overall patient satisfaction index, and presence of residual rectal prolapse also were evaluated. At a mean follow-up of 27.2 (range, 24-34) months, symptoms significantly improved, with 80 percent of excellent/good results and none of the ten operated patients showed a recurrence of rectal ulcer. Operative time, hospital stay, and time to return to normal activity were similar to those reported after stapled transanal rectal resection for obstructed defecation, whereas postoperative pain was slightly higher. One patient complained of perineal abscess, requiring surgery. The stapled transanal rectal resection is safe and effective in the cure of solitary rectal ulcer associated with internal rectal prolapse, with minimal complications and no recurrences after two years. Randomized trials with sufficient number of patients are necessary to compare the efficacy of stapled transanal

  3. Stapled hemorrhoidopexy: Clinical results of 65 cases

    Directory of Open Access Journals (Sweden)

    Ahmet Pergel

    2012-09-01

    Full Text Available Objectives: To present results of our patients underwentstapled hemorrhoidopexy due to hemorrhoidal diseaseand discuss in accompaniment with the literature.Material and methods: The patients, who diagnosed by3rd-4th degree hemorrhoidal disease and underwent hemorrhoidopexywith Longo method between January, 2009and April, 2011, were included. All data were prospectivelycollected and retrospectively examined. The patientswere evaluated in terms of demographic properties, complaintson admission, and postoperative complications.Results: Forty-three (66% of 65 patients were male,22 (34% were female. The mean age was 38±11.9(range:23-76 years. The most frequent complaints werebleeding, swelling, itching, pain, constipation respectively.Third degree hemorrhoid was present in fifty-eight (89%patients, 4th degree hemorrhoid was in 7 (11% patients.The mean operation duration was 37.6±8.1(range:24-55minutes, the mean hospitalization duration was 27±7.8(range:20-76 hours. One or more complication developedin total 17 (26% patients. As complication, bleedingwas determined in 13 (20% patients, pain was in 6 (9%,urinary retention was in 2 (3%, tenesmus was in 3 (5%,external hemorrhoidal thrombosis was in 1 (2%, and recurrencewas in 4 (6%.Conclusions: The patients can return their daily activitiesearly with stapled hemorrhoidopexy because of less painand quick recovery period. We consider that appropriatepatient selection and proper application of the techniqueare important in the success of this method. Particularly in3rd degree hemorrhoidal disease, Longo’s technique canbe suggested as an alternative to classical methods. JClin Exp Invest 2012; 3 (3: 340-344Key words: Hemorrhoidal disease, stapled hemorrhoidopexy,Longo’s procedure

  4. Stapled peptides as a new technology to investigate protein-protein interactions in human platelets.

    Science.gov (United States)

    Iegre, Jessica; Ahmed, Niaz S; Gaynord, Josephine S; Wu, Yuteng; Herlihy, Kara M; Tan, Yaw Sing; Lopes-Pires, Maria E; Jha, Rupam; Lau, Yu Heng; Sore, Hannah F; Verma, Chandra; O' Donovan, Daniel H; Pugh, Nicholas; Spring, David R

    2018-05-28

    Platelets are blood cells with numerous crucial pathophysiological roles in hemostasis, cardiovascular thrombotic events and cancer metastasis. Platelet activation requires the engagement of intracellular signalling pathways that involve protein-protein interactions (PPIs). A better understanding of these pathways is therefore crucial for the development of selective anti-platelet drugs. New strategies for studying PPIs in human platelets are required to overcome limitations associated with conventional platelet research methods. For example, small molecule inhibitors can lack selectivity and are often difficult to design and synthesise. Additionally, development of transgenic animal models is costly and time-consuming and conventional recombinant techniques are ineffective due to the lack of a nucleus in platelets. Herein, we describe the generation of a library of novel, functionalised stapled peptides and their first application in the investigation of platelet PPIs. Moreover, the use of platelet-permeable stapled Bim BH3 peptides confirms the part of Bim in phosphatidyl-serine (PS) exposure and reveals a role for the Bim protein in platelet activatory processes. Our work demonstrates that functionalised stapled peptides are a complementary alternative to conventional platelet research methods, and could make a significant contribution to the understanding of platelet signalling pathways and hence to the development of anti-platelet drugs.

  5. Radiolucent rings around bioabsorbable anchors after rotator cuff repair are not associated with clinical outcomes.

    Science.gov (United States)

    Park, Jin-Young; Jang, Suk-Hwan; Oh, Kyung-Soo; Li, Yi Jin

    2017-11-01

    Various researchers have observed small areas of osteolysis after using bioabsorbable anchors in shoulder surgeries. The purpose of this study is to determine whether radiographic perianchor radiolucent rings after rotator cuff repair are associated with the failure of repair and also assess their clinical implications. Further, the most frequent location of the radiolucent rings in the double-row suture bridge configuration was also assessed. One hundred and twenty-nine consecutive patients who underwent arthroscopic rotator cuff repair by suture bridge technique were retrospectively evaluated radiographically and clinically. The number and size of the rings that appeared at each follow-up were recorded. Also, the locations of each ring were recorded as anterior, middle or posterior, and medial or lateral according to the construct of the anchors used for suture bridge technique. The size of the tear, the number of anchors used and age of the patients were compared. Re-tear rates according to ultrasound examinations were also analyzed. After rotator cuff repair, the mean American Shoulder and Elbow Surgeons (ASES) score increased from 46.7 to 88.0 and the overall re-tear rate was 8.5% (11 cases). Seventy-three patients (56.6%) showed RR (total number of 99 rings) at least once during the course of their follow-up and the rings appeared at a mean period of 18.2 months after surgery. Mean size of the rings initially was 5.6 mm and the rings increased or decreased in mean size of 0.4 mm during mean follow-up of 37 months. No correlation was seen with the number of RRs and the rate of re-tears, number of anchors, size of tears, and clinical outcome as determined by the ASES score. Radiolucent ring measurement reproducibility was confirmed by independent, repeated measurements. The rings appeared mostly at anteromedial anchors (75 rings, 75.8%) and the authors suggest that mechanical factors may play a role for the cause of radiolucent rings. The number and the

  6. Broken Bioabsorbable Tibial Interference Screw after Anterior Cruciate Ligament (ACL Reconstruction using a Semitendinosus-gracilis Graft: A Case Report

    Directory of Open Access Journals (Sweden)

    Huang ME Deborah

    2012-07-01

    Full Text Available When a patient presents with knee pain and locking after an anterior cruciate ligament (ACL reconstruction, a new meniscal injury or an osteochondral loose body are usually considered for differential diagnosis. We present the case of a 22-year-old female with just these complaints 6 months after ACL reconstruction surgery. Magnetic resonance imaging (MRI of the knee showed a broken screw tip which was later arthroscopically removed. At arthroscopy, an 11mm long broken bioabsorbable interference screw tip was found lying in the intercondylar notch; this resulted in a 0.5cm Outerbridge grade II chondral ulcer located at mid- patella. Both menisci and cruciate ligaments were intact and no other loose bodies were found in the knee joint.

  7. Use of a flexible implant and bioabsorbable anchor for deltoid rupture repair in bimalleolar equivalent Weber B ankle fractures.

    Science.gov (United States)

    Luckino, Frank A; Hardy, Mark A

    2015-01-01

    Supination external rotation ankle fractures are the most common ankle fracture subtype. Deltoid ligament injuries have often been associated with this type of injury pattern. A missed injury can lead to post-traumatic arthritis and persistent pain. The current data do not support acute deltoid rupture repair. This has been based primarily on level III and IV studies in which less than satisfactory results were reported. We believe that acute deltoid rupture repair could be indicated in select cases. We have outlined a new deltoid repair technique for use with bimalleolar, equivalent supination external rotation ankle fractures using a flexible implant and bioabsorbable anchor. Copyright © 2015 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  8. Degradation of bioabsorbable Mg-based alloys: Assessment of the effects of insoluble corrosion products and joint effects of alloying components on mammalian cells.

    Science.gov (United States)

    Grillo, Claudia A; Alvarez, Florencia; Fernández Lorenzo de Mele, Mónica A

    2016-01-01

    This work is focused on the processes occurring at the bioabsorbable metallic biomaterial/cell interfaces that may lead to toxicity. A critical analysis of the results obtained when degradable metal disks (pure Mg and rare earth-containing alloys (ZEK100 alloys)) are in direct contact with cell culture and those obtained with indirect methods such as the use of metal salts and extracts was made. Viability was assessed by Acridine Orange dye, neutral red and clonogenic assays. The effects of concentration of corrosion products and possible joint effects of the binary and ternary combinations of La, Zn and Mg ions, as constituents of ZEK alloys, were evaluated on a mammalian cell culture. In all cases more detrimental effects were found for pure Mg than for the alloys. Experiments with disks showed that gradual alterations in pH and in the amount of corrosion products were better tolerated by cells and resulted in higher viability than abrupt changes. In addition, viability was dependent on the distance from the source of ions. Experiments with extracts showed that the effect of insoluble degradation products was highly detrimental. Indirect tests with Zn ions revealed that harmful effects may be found at concentrations ≥ 150 μM and at ≥ 100 μM in mixtures with Mg. These mixtures lead to more deleterious effects than single ions. Results highlight the need to develop a battery of tests to evaluate the biocompatibility of bioabsorbable biomaterials. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Comparison of skin staples with sutures for anastomosis of the small intestine in dogs.

    Science.gov (United States)

    Coolman, B R; Ehrhart, N; Pijanowski, G; Ehrhart, E J; Coolman, S L

    2000-01-01

    To develop a technique for approximation of end-to-end intestinal anastomoses by using a disposable skin stapler and to compare the stapling technique with an interrupted hand-sewn approximating end-to-end anastomosis of the canine jejunum. In vitro evaluation of the stapling technique, followed by an in vivo study of healing and clinical response in dogs. 18 mixed-breed adult dogs. The anastomotic technique was developed and tested in fresh canine jejunum. Fourteen stapled approximating anastomoses (SAA) and 14 hand-sewn approximating anastomoses (HAA) were performed in 6 cadavers under simulated surgical conditions. Anastomotic construction times, initial bursting strengths, initial lumen diameters, and gross appearance of the 2 techniques were compared. Healing and clinical response were evaluated in 12 purpose-bred dogs assigned to 2 groups of 6 animals each. Each dog had 1 SAA and 1 HAA performed in the jejunum, 50 cm apart. Six dogs were killed on postoperative day 4, and 6 dogs were killed on postoperative day 21. Anastomotic construction time, gross and histological healing, bursting strength, lumen diameter, and circumference were compared between techniques. Mean construction time for SAA was significantly faster than for HAA (P = .0001). None of the anastomoses leaked, and there were no major clinical complications in any dog. Bursting strengths were not significantly different at any time for the 2 techniques. Initial bursting strength was 31% to 35% of the normal jejunum. A nonsignificant decrease in bursting strength was observed by postoperative day 4 (26% to 28% of normal), and a significant increase in bursting strength was observed by postoperative day 21 (100% to 109% of normal). Neither technique decreased the initial lumen diameter. However, both techniques resulted in a similar degree of luminal stenosis as the anastomoses healed. Anastomotic lumen diameter was significantly decreased from normal in both groups at day 4 (86% to 88% of normal

  10. A Buffer Stock Model to Ensure Price Stabilization and Availability of Seasonal Staple Food under Free Trade Considerations

    Directory of Open Access Journals (Sweden)

    Wahyudi Sutopo

    2012-07-01

    Full Text Available The price volatility and scarcity have been became a great problem in the distribution system of seasonal staple food produced by agro industry. It has salient supply disparity during the harvest and planting season. This condition could cause disadvantages to the stakeholders such as producer, wholesaler, consumer, and government. This paper proposes a buffer stock model under free trade considerations to substitute quantitative restrictions and tariffs by indirect market intervention instrument. The instrument was developed through buffer stock scheme in accordance with warehouse receipt system (WRS and collateral management system. The public service institution for staple food buffer stock (BLUPP is proposed as wholesaler’s competitor with main responsibility to ensure price stabilization and availability of staple food. Multi criteria decision making is formulated as single objective a mixed integer non linear programming (MINLP. The result shows that the proposed model can be applied to solve the distribution problem and can give more promising outcome than its counterpart, the direct market intervention instrument.

  11. Comparison of circular- and linear-stapled gastrojejunostomy in laparoscopic Roux-en-Y gastric bypass: a multicenter study.

    Science.gov (United States)

    Major, Piotr; Janik, Michał R; Wysocki, Michał; Walędziak, Maciej; Pędziwiatr, Michał; Kowalewski, Piotr K; Małczak, Piotr; Paśnik, Krzysztof; Budzyński, Andrzej

    2017-06-01

    Laparoscopic Roux-en-Y gastric bypass (LRYGB) is a common, well-established procedure, but no consensus regarding selection of the gastrojejunostomy (GJ) technique has been reached, and standardization of this precise technique is far from being achieved. To compare circular-stapled and linear-stapled GJ in LRYGB in terms of operative time and postoperative complications. This retrospective case-control study compared the perioperative and postoperative outcomes of LRYGB with a circular-stapled (LRYGB-CS) versus linear-stapled (LRYGB-LS) gastrojejunostomy. All patients, operated on in two academic referral care centers for bariatric surgery, were enrolled from April 2013 to June 2016. 457 patients were included (255 and 202 respectively in the LRYGB-CS and LRYGB-LS groups). After matching the groups for age, sex, body mass index, arterial hypertension, and presence of type 2 diabetes in a 1 : 1 ratio, 99 patients were enrolled in each. The total operative time was longer in the LRYGB-LS group (140 vs. 85 min, p < 0.001). The postoperative hemorrhage and wound infection rates were lower in the LRYGB-LS group (2.1% vs. 10.3%, p = 0.021, and 1.0% vs. 9.3%, p = 0.011). The readmission rates were comparable (8.2% vs. 6.1%, p = 0.593). There was no significant difference in the incidence of gastrojejunostomy leakage, stricture, port-site hernia, or marginal ulcer. Both anastomosis types for LRYGB are safe and have low and comparable risks of postoperative complications. After LRYGB-CS, postoperative bleeding and wound infections are slightly more frequent; however, the operative time is shorter.

  12. An enhanced functional interrogation/manipulation of intracellular signaling pathways with the peptide 'stapling' technology.

    Science.gov (United States)

    He, Y; Chen, D; Zheng, W

    2015-11-12

    Specific protein-protein interactions (PPIs) constitute a key underlying mechanism for the presence of a multitude of intracellular signaling pathways, which are essential for the survival of normal and cancer cells. Specific molecular blockers for a crucial PPI would therefore be invaluable tools for an enhanced functional interrogation of the signaling pathway harboring this particular PPI. On the other hand, if a particular PPI is essential for the survival of cancer cells but is absent in or dispensable for the survival of normal cells, its specific molecular blockers could potentially be developed into effective anticancer therapeutics. Due to the flat and extended PPI interface, it would be conceivably difficult for small molecules to achieve an effective blockade, a problem which could be potentially circumvented with peptides or proteins. However, the well-documented proteolytic instability and cellular impermeability of peptides and proteins in general would make their developing into effective intracellular PPI blockers quite a challenge. With the advent of the peptide 'stapling' technology which was demonstrated to be able to stabilize the α-helical conformation of a peptide via bridging two neighboring amino-acid side chains with a 'molecular staple', a linear parent peptide could be transformed into a stronger PPI blocker with enhanced proteolytic stability and cellular permeability. This review will furnish an account on the peptide 'stapling' technology and its exploitation in efforts to achieve an enhanced functional interrogation or manipulation of intracellular signaling pathways especially those that are cancer relevant.

  13. Anesthetic management of the SRS™ Endoscopic Stapling System for gastro-esophageal reflux disease.

    Science.gov (United States)

    Topuz, Ufuk; Umutoglu, Tarik; Bakan, Mefkur; Ozturk, Erdogan

    2013-01-14

    The SRS(TM) Endoscopic Stapling System (Medigus, Tel Aviv, Israel) is a new tool capable of creating a totally endoscopic fundoplication, combined with an endoscope, endoscopic ultrasound and a surgical stapler. SRS(TM) endoscopic stapling for gastro-esophageal reflux disease is a minimally invasive, outpatient procedure, which requires general anesthesia with positive-pressure ventilation. Keeping the patient on positive end-expiratory pressure (PEEP) may minimize the pressure gradient between the esophagus and the mediastinum, as well as help to prevent air from leaking around the screws and causing pneumomediastinum. In addition, in patients with hiatal hernia, higher PEEP levels may be required to increase intra-thoracic pressure and to force the stomach to slide into the abdomen for ease of endoscopy. We advise smoother emergence from anesthesia, taking precautions for retching, postoperative nausea and vomiting (PONV), while coughing and gagging during extubation and PONV may affect the success of the procedure. Total intravenous anesthesia with propofol and remifentanil seems to be a good choice for these reasons.

  14. Comparison of circular- and linear-stapled gastrojejunostomy in laparoscopic Roux-en-Y gastric bypass: a multicenter study

    Directory of Open Access Journals (Sweden)

    Piotr Major

    2017-03-01

    Full Text Available Introduction : Laparoscopic Roux-en-Y gastric bypass (LRYGB is a common, well-established procedure, but no consensus regarding selection of the gastrojejunostomy (GJ technique has been reached, and standardization of this precise technique is far from being achieved. Aim : To compare circular-stapled and linear-stapled GJ in LRYGB in terms of operative time and postoperative complications. Material and methods: This retrospective case-control study compared the perioperative and postoperative outcomes of LRYGB with a circular-stapled (LRYGB-CS versus linear-stapled (LRYGB-LS gastrojejunostomy. All patients, operated on in two academic referral care centers for bariatric surgery, were enrolled from April 2013 to June 2016. 457 patients were included (255 and 202 respectively in the LRYGB-CS and LRYGB-LS groups. After matching the groups for age, sex, body mass index, arterial hypertension, and presence of type 2 diabetes in a 1 : 1 ratio, 99 patients were enrolled in each. Results : The total operative time was longer in the LRYGB-LS group (140 vs. 85 min, p < 0.001. The postoperative hemorrhage and wound infection rates were lower in the LRYGB-LS group (2.1% vs. 10.3%, p = 0.021, and 1.0% vs. 9.3%, p = 0.011. The readmission rates were comparable (8.2% vs. 6.1%, p = 0.593. There was no significant difference in the incidence of gastrojejunostomy leakage, stricture, port-site hernia, or marginal ulcer. Conclusions : Both anastomosis types for LRYGB are safe and have low and comparable risks of postoperative complications. After LRYGB-CS, postoperative bleeding and wound infections are slightly more frequent; however, the operative time is shorter.

  15. Ligation of the Rectum with an Extracorporeal Sliding Knot Facilitating Laparoscopic Cross-Stapling

    DEFF Research Database (Denmark)

    Bulut, Orhan

    2013-01-01

    : The extracorporeal ligation of the rectum just proximal to the cut end of the rectum before applying the linear stapling stapler facilitates the procedure and requires only a few firings of the stapler during the laparoscopic rectal resections. Results: Ten patients with a median age of 72 years underwent rectal...

  16. Carotenoids in staple cereals: Metabolism, regulation, and genetic manipulation

    Directory of Open Access Journals (Sweden)

    shengnan zhai

    2016-08-01

    Full Text Available Carotenoids play a critical role in animal and human health. Animals and humans are unable to synthesize carotenoids de novo, and therefore rely upon diet as sources of these compounds. However, major staple cereals often contain only small amounts of carotenoids in their grain. Consequently, there is considerable interest in genetic manipulation of carotenoid content in cereal grain. In this review, we focus on carotenoid metabolism and regulation in non-green plant tissues, as well as genetic manipulation in staple cereals such as rice, maize, and wheat. Significant progress has been made in three aspects: (1 seven carotenogenes play vital roles in carotenoid regulation in non-green plant tissues, including DXS (1-deoxyxylulose-5-phosphate synthase influencing isoprenoid precursor supply, PSY (phytoene synthase, LCYB (β-cyclase and LCYE (ε-cyclase controlling biosynthesis, HYDB (1-hydroxy-2-methyl-2-(E-butenyl 4-diphosphate reductase and CCDs (carotenoid cleavage dioxygenases responsible for degradation, and OR (orange conditioning sequestration sink; (2 pro-vitamin A-biofortified crops, such as rice and maize, were developed by either metabolic engineering or marker-assisted breeding; (3 QTLs for carotenoid content on chromosomes 3B, 7A, and 7B were consistently identified, eight carotenogenes including 23 loci were detected, and ten gene-specific markers for carotenoid accumulation were developed and applied in wheat improvement. A comprehensive and deeper understanding of the regulatory mechanisms of carotenoid metabolism in crops will be benefitical in improving our precision in improving carotenoid contents. Genomic selection and gene editing are emerging as transformative technologies for vitamin A biofortification.

  17. Lung abscess mimicking lung cancer developed around staples in a patient with permanent tracheostoma.

    Science.gov (United States)

    Watanabe, Yui; Aoki, Masaya; Suzuki, Soichi; Umehara, Tadashi; Harada, Aya; Wakida, Kazuhiro; Nagata, Toshiyuki; Kariatsumari, Kota; Nakamura, Yoshihiro; Sato, Masami

    2015-11-01

    A 68-year-old male with a tracheostoma due to hypopharyngeal cancer was admitted because his chest computed tomography (CT) showed a small nodule in the right middle lobe. Following a partial resection of the right middle lobe, histopathological diagnosis of the resected sample was that of organizing pneumonia. Eleven months later, chest CT showed a mass with pleural indentation and spiculation in the right middle lobe. 18-Fluorodeoxyglucose-positron emission tomography showed significant accumulation in the middle lobe tumor mass shadow. The abnormal chest shadow that had developed around surgical staples suggested inadequate resection and tumor recurrence. As the abnormal radiological shadow was enlarging, middle lobectomy was carried out. Histological examination revealed that the tumor was a lung abscess without malignant features. This is a unique case of lung abscess mimicking lung cancer which developed around staples used during partial resection of the lung.

  18. Heavy and toxic metals in staple foodstuffs and agriproduct from contaminated soils

    International Nuclear Information System (INIS)

    Gorbunov, A.V.; Kistanov, A.A.; Lyapunov, S.M.; Okina, O.I.; Frontas'eva, M.V.; Ramadan, A.B.

    2002-01-01

    This article presents basic data on the content of Cr, Fe, Ni, Cu, Zn, As, Cd, Sb, Hg, and Pb in staple foodstuffs and agriproducts grown in Russia (Astrakhan region and the town of Belovo) and Egypt (Helwan region). The dependence of the concentration of metals in agriproducts on the content and chemical form of existence in irrigation water and soils is indicated

  19. Heavy and Toxic Metals in Staple Foodstuffs and Agriproduct from Contaminated Soils

    CERN Document Server

    Gorbunov, A V; Kistanov, A A; Lyapunov, S M; Okina, O I; Ramadan, A B

    2002-01-01

    This article presents basic data on the content of Cr, Fe, Ni, Cu, Zn, As, Cd, Sb, Hg, and Pb in staple foodstuffs and agriproduct grown in Russia (Astrakhan region and the town of Belovo) and Egypt (Helwan region). The dependence of the concentration of metals in agriproducts on the content and chemical form of existence in irrigation water and soils is indicated.

  20. Breakfast staple types affect brain gray matter volume and cognitive function in healthy children.

    Directory of Open Access Journals (Sweden)

    Yasuyuki Taki

    Full Text Available Childhood diet is important for brain development. Furthermore, the quality of breakfast is thought to affect the cognitive functioning of well-nourished children. To analyze the relationship among breakfast staple type, gray matter volume, and intelligence quotient (IQ in 290 healthy children, we used magnetic resonance images and applied voxel-based morphometry. We divided subjects into rice, bread, and both groups according to their breakfast staple. We showed that the rice group had a significantly larger gray matter ratio (gray matter volume percentage divided by intracranial volume and significantly larger regional gray matter volumes of several regions, including the left superior temporal gyrus. The bread group had significantly larger regional gray and white matter volumes of several regions, including the right frontoparietal region. The perceptual organization index (POI; IQ subcomponent of the rice group was significantly higher than that of the bread group. All analyses were adjusted for age, gender, intracranial volume, socioeconomic status, average weekly frequency of having breakfast, and number of side dishes eaten for breakfast. Although several factors may have affected the results, one possible mechanism underlying the difference between the bread and the rice groups may be the difference in the glycemic index (GI of these two substances; foods with a low GI are associated with less blood-glucose fluctuation than are those with a high GI. Our study suggests that breakfast staple type affects brain gray and white matter volumes and cognitive function in healthy children; therefore, a diet of optimal nutrition is important for brain maturation during childhood and adolescence.

  1. Breakfast staple types affect brain gray matter volume and cognitive function in healthy children.

    Science.gov (United States)

    Taki, Yasuyuki; Hashizume, Hiroshi; Sassa, Yuko; Takeuchi, Hikaru; Asano, Michiko; Asano, Kohei; Kawashima, Ryuta

    2010-12-08

    Childhood diet is important for brain development. Furthermore, the quality of breakfast is thought to affect the cognitive functioning of well-nourished children. To analyze the relationship among breakfast staple type, gray matter volume, and intelligence quotient (IQ) in 290 healthy children, we used magnetic resonance images and applied voxel-based morphometry. We divided subjects into rice, bread, and both groups according to their breakfast staple. We showed that the rice group had a significantly larger gray matter ratio (gray matter volume percentage divided by intracranial volume) and significantly larger regional gray matter volumes of several regions, including the left superior temporal gyrus. The bread group had significantly larger regional gray and white matter volumes of several regions, including the right frontoparietal region. The perceptual organization index (POI; IQ subcomponent) of the rice group was significantly higher than that of the bread group. All analyses were adjusted for age, gender, intracranial volume, socioeconomic status, average weekly frequency of having breakfast, and number of side dishes eaten for breakfast. Although several factors may have affected the results, one possible mechanism underlying the difference between the bread and the rice groups may be the difference in the glycemic index (GI) of these two substances; foods with a low GI are associated with less blood-glucose fluctuation than are those with a high GI. Our study suggests that breakfast staple type affects brain gray and white matter volumes and cognitive function in healthy children; therefore, a diet of optimal nutrition is important for brain maturation during childhood and adolescence.

  2. 78 FR 17637 - Polyester Staple Fiber From Taiwan: Preliminary Results of Antidumping Duty Administrative Review...

    Science.gov (United States)

    2013-03-22

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-583-833] Polyester Staple Fiber From... Administration, International Trade Administration, Department of Commerce. SUMMARY: The Department of Commerce.../CVD Operations, Office 1, Import Administration, International Trade Administration, U.S. Department...

  3. The use of disposable skin staples for intestinal resection and anastomosis in 63 dogs: 2000 to 2014.

    Science.gov (United States)

    Rosenbaum, J M; Coolman, B R; Davidson, B L; Daly, M L; Rexing, J F; Eatroff, A E

    2016-11-01

    To describe the use of disposable skin staples for intestinal resection and anastomosis in dogs and report associated dehiscence and mortality rates. Retrospective evaluation of medical records of dogs that underwent intestinal resection and anastomosis using disposable skin staples between 2000 and 2014. Data regarding patient signalment, indication for surgery, location of the resection and anastomosis, number of procedures performed, evidence of peritonitis at the time of surgery, surgeon qualifications, dehiscence, and mortality were obtained from the medical records. Mortality was defined as failure to survive beyond 10 days following resection and anastomosis. The overall mortality rate of patients undergoing intestinal resection and anastomosis was 12·7% (8/63). The most common indication for resection and anastomosis was neoplasia (20/63 [31·7%]), followed by foreign body removal (19/63 [30·2%]). The overall dehiscence rate was 4·8% (3/63). No difference in mortality associated with indication for surgery, whether multiple procedures were performed, surgeon qualifications, or evidence of peritonitis at the time of surgery was identified. In this retrospective study, the overall mortality and dehiscence rates using disposable skin staples were similar to previously reported outcomes following resection and anastomosis. © 2016 British Small Animal Veterinary Association.

  4. Degradation of bioabsorbable Mg-based alloys: Assessment of the effects of insoluble corrosion products and joint effects of alloying components on mammalian cells

    International Nuclear Information System (INIS)

    Grillo, Claudia A.; Alvarez, Florencia; Fernández Lorenzo de Mele, Mónica A.

    2016-01-01

    This work is focused on the processes occurring at the bioabsorbable metallic biomaterial/cell interfaces that may lead to toxicity. A critical analysis of the results obtained when degradable metal disks (pure Mg and rare earth-containing alloys (ZEK100 alloys)) are in direct contact with cell culture and those obtained with indirect methods such as the use of metal salts and extracts was made. Viability was assessed by Acridine Orange dye, neutral red and clonogenic assays. The effects of concentration of corrosion products and possible joint effects of the binary and ternary combinations of La, Zn and Mg ions, as constituents of ZEK alloys, were evaluated on a mammalian cell culture. In all cases more detrimental effects were found for pure Mg than for the alloys. Experiments with disks showed that gradual alterations in pH and in the amount of corrosion products were better tolerated by cells and resulted in higher viability than abrupt changes. In addition, viability was dependent on the distance from the source of ions. Experiments with extracts showed that the effect of insoluble degradation products was highly detrimental. Indirect tests with Zn ions revealed that harmful effects may be found at concentrations ≥ 150 μM and at ≥ 100 μM in mixtures with Mg. These mixtures lead to more deleterious effects than single ions. Results highlight the need to develop a battery of tests to evaluate the biocompatibility of bioabsorbable biomaterials. - Highlights: • A metal disk setup is better in simulating in vivo situations than extracts and salts. • The biodegradation process and cell metabolism were interdependent. • Zn (100 μM) and Mg (8.2 × 10"3 μM) mixtures are more toxic than single Zn or Mg. • Insoluble degradation products of Mg showed high negative effect on cell viability.

  5. Perioperative topical nitrate and sphincter function in patients undergoing transanal stapled anastomosis: a randomized, placebo-controlled, double-blinded trial.

    LENUS (Irish Health Repository)

    Winter, D C

    2012-02-03

    PURPOSE: The use of transanal stapling devices may impair continence because of digital dilatation and\\/or instrumentation. This study assessed the effect of pharmacological dilatation of the sphincter prior to stapler insertion. METHODS: A randomized, placebo-controlled, double-blinded study of 60 patients undergoing transanal stapled anastomosis was undertaken. Consenting patients were randomly assigned to receive a single intraoperative dose of topical 0.2 percent nitroglycerin (glyceryl trinitrate) ointment or nitroglycerin-free placebo. All patients were assessed preoperatively and postoperatively by clinical methods (Wexner incontinence scores and examination), anorectal manometry by a station pull-through technique, and endoanal ultrasonography. RESULTS: Intraoperative mean (+\\/-SEM) resting pressures (mmHg) were significantly reduced by nitroglycerin compared with prenitroglycerin levels (9.9 +\\/- 0.9 vs. 50.5 +\\/- 2.7; P = 0.002) or controls (56.0 +\\/- 3.2; P = 0.001). Twenty-one of the 28 controls (75 percent) but only 4 of the 32 patients in the nitroglycerin group (12.5 percent) required digital dilatation to insert the stapling instrument ( P = 0.003). Squeeze pressures were unaltered by the intervention but mean resting pressures were higher in the nitroglycerin group postoperatively (52.9 +\\/- 3.2 - 31.6 +\\/- 1.3 = 21.3 mmHg; 95 percent confidence interval, 14-27). Incontinence scores were lower in the nitroglycerin group at the 3-month (1.1 +\\/- 0.2 vs. 4.6 +\\/- 0.3; P = 0.003) and 12-month (0.9 +\\/- 0.1 vs. 4.4 +\\/- 0.3; P = 0.002) clinic visits. CONCLUSION: Preoperative nitroglycerin dilatation protects sphincter function in patients undergoing transanal stapled anastomoses.

  6. Randomized clinical trial of biodegradeable intraluminal sheath to prevent anastomotic leak after stapled colorectal anastomosis

    NARCIS (Netherlands)

    Bakker, I S; Morks, A N; Ten Cate Hoedemaker, H O; Burgerhof, J G M; Leuvenink, H G; van Praagh, J B; Ploeg, R J; Havenga, K

    Background: Anastomotic leakage is a potential major complication after colorectal surgery. The C-seal was developed to help reduce the clinical leakage rate. It is an intraluminal sheath that is stapled proximal to a colorectal anastomosis, covering it intraluminally and thus preventing intestinal

  7. Randomized clinical trial of symptom control after stapled anopexy or diathermy excision for haemorrhoid prolapse

    DEFF Research Database (Denmark)

    Nyström, P-O; Qvist, N; Raahave, D

    2010-01-01

    BACKGROUND: : This multicentre randomized clinical trial studied how symptoms improved after either stapled anopexy or diathermy excision of haemorrhoids. METHODS: : The study involved 18 hospitals in Sweden, Denmark and the UK. Some 207 patients were randomized to either anopexy or Milligan-Morg...

  8. Modified Longo's stapled hemorrhoidopexy with additional traction sutures for the treatment of residual prolapsed piles.

    Science.gov (United States)

    Chen, Chuang-Wei; Kang, Jung-Cheng; Wu, Chang-Chieh; Hsiao, Cheng-Wen; Jao, Shu-Wen

    2008-03-01

    Residual prolapsed piles is a problem after the stapled hemorrhoidopexy, especially in large third- or fourth-degree hemorrhoids. We have developed a method using additional traction sutures along with modified Longo's procedure to manage this problem. From January 2005 to October 2005, 30 consecutive patients with symptomatic third- or fourth-degree hemorrhoids who underwent the modified Longo's stapled hemorrhoidopexy with additional traction sutures in a single institution were collected. The demographics, postoperative pain score, surgical features, outcomes, and early and late complications were recorded. All patients were followed for a mean duration of 8.8 (range, 4-15) months. Thirty patients (17 males) with a mean age of 45 (range, 27-63) years were identified. The mean postoperative pain score on the morning of the first postoperative day was 2.8 (range, 1-4). The mean duration of operation was 30.7 (range, 25-37) min. The mean duration of hospital stay was 2 (range, 1-3) days. The mean days for patients to resume normal work was 6.7 (range, 4-9) days. No other procedure-related complications occurred in all patients. There was no early complication except for fecal urgency found in one patient during the first postoperative days. Regarding the late complications, no residual prolapsed piles, persistent anal pain, incontinence, anal stenosis, or recurrent symptoms were found. Our preliminary experiences indicated that this modified procedures truly contributed to reduce the residual internal hemorrhoids and maintained the benefits of stapled hemorrhoidopexy. Randomized trial and long-term follow-up warrant to determine possible surgical and functional outcome.

  9. The elemental analysis of staple foods for children in Tanzania as a step to the improvement of their nutrition and health

    Energy Technology Data Exchange (ETDEWEB)

    Mohammed, Najat K. [Department of Physics, School of Electronics and Physical Sciences, University of Surrey, Guildford, Surrey GU2 7XH (United Kingdom)], E-mail: njkassim@yahoo.com; Spyrou, Nicholas M. [Department of Physics, School of Electronics and Physical Sciences, University of Surrey, Guildford, Surrey GU2 7XH (United Kingdom)

    2009-03-15

    The objective of this study was to evaluate the contents of essential elements in the two staple foods (rice and maize flour) consumed by children in Tanzania as a possible selection measure for high nutrient foods in order to combat malnutrition. Samples were analysed using proton-induced X-ray emission (PIXE) at the University of Surrey Ion Beam Centre. The mean concentrations of elements determined in the two staple foods are presented and compared with the mean concentrations published in the literature.

  10. The elemental analysis of staple foods for children in Tanzania as a step to the improvement of their nutrition and health

    International Nuclear Information System (INIS)

    Mohammed, Najat K.; Spyrou, Nicholas M.

    2009-01-01

    The objective of this study was to evaluate the contents of essential elements in the two staple foods (rice and maize flour) consumed by children in Tanzania as a possible selection measure for high nutrient foods in order to combat malnutrition. Samples were analysed using proton-induced X-ray emission (PIXE) at the University of Surrey Ion Beam Centre. The mean concentrations of elements determined in the two staple foods are presented and compared with the mean concentrations published in the literature

  11. Using the Uganda National Panel Survey to analyze the effect of staple food consumption on undernourishment in Ugandan children

    Directory of Open Access Journals (Sweden)

    Michelle M. Amaral

    2017-07-01

    Full Text Available Abstract Background The United Nations’ Millennium Development Goals Report, 2015, documents that, since 1990, the number of stunted children in sub-Saharan Africa has increased by 33% even though it has fallen in all other world regions. Recognizing this, in 2011 the Government of Uganda implemented a 5-year Nutrition Action Plan. One important tenet of the Plan is to lessen malnutrition in young children by discouraging over-consumption of nutritionally deficient, but plentiful, staple foods, which it defines as a type of food insecurity. Methods We use a sample of 6101 observations on 3427 children age five or less compiled from three annual waves of the Uganda National Panel Survey to measure undernourishment. We also use the World Health Organization’s Child Growth Standards to create a binary variable indicating stunting and another indicating wasting for each child in each year. We then use random effects to estimate binary logistic regressions that show that greater staple food concentrations affect the probability of stunting and wasting. Results The estimated coefficients are used to compute adjusted odds ratios (OR that estimate the effect of greater staple food concentration on the likelihood of stunting and the likelihood of wasting. Controlling for other relevant covariates, these odds ratios show that a greater proportion of staple foods in a child’s diet increases the likelihood of stunting (OR = 1.007, p = 0.005 as well as wasting (OR = 1.011, p = 0.034. Stunting is confirmed with subsamples of males only (OR = 1.006, p = 0.05 and females only (OR = 1.008, p = 0.027, suggesting that the finding is not gender specific. Another subsample of children aged 12 months or less, most of whom do not yet consume solid food, shows no statistically significant relationship, thus supporting the validity of the other findings. Conclusion Diets containing larger proportions of staple foods are associated with greater

  12. New approach to large haemorrhoidal prolapse: double stapled haemorrhoidopexy.

    Science.gov (United States)

    Naldini, Gabriele; Martellucci, Jacopo; Talento, Pasquale; Caviglia, Angelo; Moraldi, Luca; Rossi, Mauro

    2009-12-01

    To verify if in large haemorrhoidal prolapse (independently from the degree) in patients with no symptoms of obstructed defaecation syndrome, the use of a stapled hemorrhoidopexy variant, comprising a double stapler haemorrhoidopexy (DSH), makes it possible to reduce the percentage of failures or relapses and to standardise an objective intraoperative parameter for the purpose of quantifying internal prolapses which can then be used as a guide in determining the type of treatment to be provided. Between June 2003 and June 2004, 353 patients were treated for haemorrhoidal prolapse. The patients suffering from large haemorrhoidal prolapse occupying more than half of the length of the anal dilator were intraoperatively selected for DSH. Eighty-three patients (23.5%) underwent a DSH. The degrees of the large haemorrhoidal prolapse intraoperatively selected for DSH were sub-divided as follows: 7.2% (second), 24% (third) and 68.6% (fourth). The follow-up period was 48 months. There were three cases (3.6%) of residual illnesses and five cases (6%) of a relapse. The following complications were recorded: urgency at <3 months (7.2%), haemostasis revisions (2.4%) and spontaneously draining anterior haematoma (1.2%). The results of the 270 haemorrhoidal prolapse (38 second degree, 159 third degree and 130 fourth degree) treated with the procedure for prolapse and haemorrhoids were: nine (3.3%) residual illness and 12 (4.44%) relapse illness. The following complications were recorded: urgency at <3 months (6.6%), haemostasis revisions (2.5%) and spontaneously draining anterior haematoma (0.7%). The intraoperative selection criterion was both efficacious and reproducible. This variant technique, which can be used in large haemorrhoidal prolapses, could allow us to further improve the quality of treatment for haemorrhoidal conditions using stapled haemorrhoidopexy, without increasing the complications.

  13. Effects of increased intra-abdominal pressure on the healing process after surgical stapling of the stomach of dogs Efeitos da elevação da pressão intra-abdominal e de seu tempo de ação na cicatrização de suturas mecânicas no estômago de cães

    Directory of Open Access Journals (Sweden)

    Nilson Chaves Jr

    2007-10-01

    Full Text Available PURPOSE: To assess the initial healing after surgical stapling of the stomach using a linear cutting stapler and creating pneumoperitoneum (12-14 mmHg for 60 minutes or 120 minutes, and compare it with the healing of a staple line not submitted to increased pressure. METHODS: A total of 30 dogs were divided into three groups of 10 animals each: Group I (control group - surgical stapling, Group II (surgical stapling and increased intra-abdominal pressure for 60 minutes and Group III (surgical stapling and increased intra-abdominal pressure for 120 minutes. All dogs were maintained under general anesthesia for two hours after surgical stapling. Seven days after surgery, the area around the staple line was macroscopically and microscopically examined. RESULTS: The macroscopic examination of the samples (n = 30 did not show dehiscence, fistula or abscess. Adhesions between the omentum and the staple line were observed in all animals of Groups II and III (n = 20, which were significantly different from Group I (p = 0.008*. The histopathological analysis showed normal healing up to day 7 in the control animals (n = 10. When these results were compared with those of Groups II and III (n = 20, non-parametric tests revealed that there was a significant difference with regard to certain parameters of the early stages of healing, such as fibroblast migration (p = 0.011*, edema (p OBJETIVO: Avaliar os efeitos do pneumoperitônio com CO2 sobre a fase inicial da cicatrização (7º dia de uma sutura gástrica mecânica em cães, com diferentes tempos de aumento da pressão intra-abdominal. MÉTODOS: Trinta cães foram divididos em três grupos e submetidos à laparotomia mediana e realização de uma sutura vertical na grande curvatura gástrica com grampeador linear cortante. Após a síntese abdominal, nos animais dos grupos II e III instalou-se pneumoperitônio com CO2, permanecendo os animais com pressão intra-abdominal entre 12 e 14 mmHg durante 60

  14. [The advantages in using cyanoacrylate glue over skin staples as a method of skin graft fixation in the pediatric burns population].

    Science.gov (United States)

    Curings, P; Vincent, P-L; Viard, R; Gir, P; Comparin, J-P; Voulliaume, D

    2017-11-23

    Local postoperative care and burn wound management can present with a certain degree of difficulty in the pediatric population. While the use of skin staples as a method of skin graft fixation is a well-known, rapid and simple method, their removal can be painful and may necessitate some sedation or even general anesthesia. We studied in this article the advantages and economic value of using the cyanoacrylate glue as a fixation method for skin grafts. A comparative study was carried out from 2012 to 2016. Hundred and eighteen infants with burns up to 5% of total body surface area were included in the study. Seventy-two infants had split thickness skin grafts fixed with skin staples. Forty-six infants had split thickness skin grafts fixed with cyanoacrylate glue. We compared the quality of graft, the sedation used during the first postoperative dressing, the length of hospital stay, the amount of glue used and the presence of complications. There is a difference between the two groups studied in terms of age and total burn surface area. The rate of graft take was 100% in both groups. The first postoperative dressing was carried out without the use of powerful analgesia in the cyanoacrylate group, while it was necessary to use general anesthesia in 64% of the skin staples group. The average length of stay in hospital after skin grafting was 4.9 days for the cyanoacrylate glue versus 6.5 days in the skin staples group. No complications were noted in the 2 groups. The use of cyanoacrylate glue allows rapid fixation of skin grafts and avoid general anesthesia for postoperative cares. Subsequently the length of hospital stay is reduced within 25%. The medico-economic value of glue protocol is highly significant compared to skin staples, while having similar good results and without significant problems. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  15. Middle-term follow-up results of Pipkin type IV femoral head fracture patients treated by reconstruction plate and bioabsorbable screws

    Directory of Open Access Journals (Sweden)

    Shan-Xi Wang

    2018-06-01

    Full Text Available Purpose: To investigate the mid-term curative effects of the treatment of Pipkin type IV femoral head fractures using a reconstruction plate and bioabsorbable screws and provide the evidence for clinical practice. Methods: From February 2010 to September 2014, 21 patients with Pipkin type IV femoral head fractures were treated surgically. There were 13 males and 8 females with an average age of 41.1 years (range, 20–65 years. The causes of the fractures included traffic accidents (13 cases, falls from a height (four cases, heavy lifting injuries (three cases, and sport injury (one case. All patients were followed up with radiography and three-dimensional reconstruction computed tomography and other checks and any complications were actively managed. Closed reduction of fracture-dislocation of the hip was attempted under general anesthesia using the Kocher-Langenbeck approach. Femoral head fractures were treated with internal fixation or excision based on the size of the fracture fragments, whereas acetabular fractures were fixed with a reconstruction plate and screws following anatomic reduction. Results: The incisions healed by primary intention in all patients after surgery, without any infection, deep venous thrombosis, or other complications. All 21 patients were followed up for 36–76 months, with an average follow-up duration of 49 months. Postoperative imaging data showed that all dislocations and fractures were anatomically reduced, and bony union of the fractures was achieved. Heterotopic ossification was found in four patients, post-traumatic osteoarthritis in three, and avascular necrosis of the femoral head in two. At the final follow-up, the assessment of hip joint function according to the Thompson-Epstein scoring scale was excellent in 10 cases, good in six cases, fair in three cases, and poor in two cases. The rate of excellent and good functional outcomes was 76.1%. Conclusion: The mid-term curative effects of a

  16. Cellular responses of bioabsorbable polymeric material and Guglielmi detachable coil in experimental aneurysms.

    Science.gov (United States)

    Murayama, Yuichi; Viñuela, Fernando; Tateshima, Satoshi; Gonzalez, Nestor R; Song, Joon K; Mahdavieh, Haleh; Iruela-Arispe, Luisa

    2002-04-01

    Acceleration of healing mechanisms is a promising approach to improve current limitations of endovascular aneurysm therapy with the use of platinum coils. We evaluated a new endovascular therapeutic, bioabsorbable polymeric material (BPM), which may promote cellular reaction in the aneurysms. Four different concentrations of lactide/glycolic acid copolymer [poly(D-L-lactic-co-glycolic acid)] (PLGA), 85/15, 75/25, 65/35, and 50/50, were used as BPMs. Sixteen experimental aneurysms were created in 8 swine. Eight-millimeter-long spiral-shaped BPMs were surgically implanted in the aneurysms without tight packing (n=3 for each BPM). Guglielmi detachable coils (GDCs) were used as control (n=4). The animals were killed 14 days after embolization, and angiographic, histological, and immunohistochemical analyses were performed. Despite loose packing of aneurysms with BPMs, faster BPMs such as 50/50 or 65/35 PLGA demonstrated more mature collagen formation and fibrosis in the sac and neck of the aneurysm. One aneurysm treated with 65/35 PLGA, 1 treated with 75/25 PLGA, and all 3 treated with 85/15 PLGA showed a neck remnant on angiography. There was a linear relationship between collagen levels and polymer degradation properties (r=-0.9513). This preliminary animal study indicates that acceleration of aneurysm healing with the use of BPM is feasible. This concept can be applied to decrease and perhaps prevent aneurysmal recanalization after endovascular treatment of cerebral aneurysms.

  17. 77 FR 62217 - Certain Polyester Staple Fiber From the People's Republic of China: Continuation of Antidumping...

    Science.gov (United States)

    2012-10-12

    ... Fiber From the People's Republic of China: Continuation of Antidumping Duty Order AGENCY: Import... staple fiber from the People's Republic of China (``PRC'') would likely lead to a continuation or... Tariff Act of 1930, as amended (``the Act'').\\1\\ \\1\\ See Initiation of Five-Year (``Sunset'') Review...

  18. Early complications after stapled transanal rectal resection performed using the Contour® Transtar™ device.

    Science.gov (United States)

    Martellucci, J; Talento, P; Carriero, A

    2011-12-01

    This study evaluated the early results (with particular reference to complications) of stapled transanal rectal resection (STARR) carried out using the CCS-30 Contour® Transtar™ device. The procedure was performed in a single centre on patients with obstucted defecation caused by rectocele or rectal intussusception. From July 2007 to February 2009, 133 patients were treated. Preoperatively, all underwent clinical examination, transanal ultrasonography, anorectal manometry and cinedefaecography. Obstructed defaecation syndrome was assessed using the Cleveland Clinic Constipation Score (CCC-S). Early postoperative complications and those occurring within 6 months were recorded. The median follow-up period was 19 (range 12-30) months. The mean ± standard deviation preoperative CCC-S of 19.4 ± 7.1 decreased to 10.1 ± 9.0 postoperatively. The early complication rate was 15.7% and included rectovaginal fistula (n = 1), rectal perforation (n = 1), posterior dehiscence (n = 4), further surgery for retained staples (n = 2), postoperative bleeding (n = 2) and postoperative impaired continence (n = 11). STARR using the Contour Transtar device seems to be effective for treating obstructed defaecation. However, serious complications may occur. © 2011 The Authors. Colorectal Disease © 2011 The Association of Coloproctology of Great Britain and Ireland.

  19. Stapling and Section of the Nasogastric Tube during Sleeve Gastrectomy: How to Prevent and Recover

    Directory of Open Access Journals (Sweden)

    A. Péquignot

    2011-07-01

    Full Text Available Bariatric surgery has become an integral part of morbid obesity treatment with well-defined indications. Some complications, specific or not, due to laparoscopic sleeve gastrectomy (LSG procedure have recently been described. We report a rare complication unpublished to date: a nasogastric section during great gastric curve stapling. A 44-year-old woman suffered of severe obesity (BMI 36.6 kg/m2 with failure of medical treatments for years. According to already published technique, a LSG was performed. Six hours postoperatively, a nurse removed the nasogastric tube according to the local protocol and the nasogastric tube was abnormally short, with staples at its extremity. Surgery was performed with peroperative endoscopy. In conclusion, this is the first publication of a nasogastric section during LSG. Therefore we report this case and propose a solution to prevent its occurrence. To avoid this kind of accident, we now systematically insert the nasogastric tube by mouth through a Guedel cannula. Then, to insert the calibrating bougie, we entirely withdraw the nasogastric tube.

  20. Transgenic biofortification of the starchy staple cassava (Manihot esculenta generates a novel sink for protein.

    Directory of Open Access Journals (Sweden)

    Mohammad Abhary

    Full Text Available Although calorie dense, the starchy, tuberous roots of cassava provide the lowest sources of dietary protein within the major staple food crops (Manihot esculenta Crantz. (Montagnac JA, Davis CR, Tanumihardjo SA. (2009 Compr Rev Food Sci Food Saf 8:181-194. Cassava was genetically modified to express zeolin, a nutritionally balanced storage protein under control of the patatin promoter. Transgenic plants accumulated zeolin within de novo protein bodies localized within the root storage tissues, resulting in total protein levels of 12.5% dry weight within this tissue, a fourfold increase compared to non-transgenic controls. No significant differences were seen for morphological or agronomic characteristics of transgenic and wild type plants in the greenhouse and field trials, but relative to controls, levels of cyanogenic compounds were reduced by up to 55% in both leaf and root tissues of transgenic plants. Data described here represent a proof of concept towards the potential transformation of cassava from a starchy staple, devoid of storage protein, to one capable of supplying inexpensive, plant-based proteins for food, feed and industrial applications.

  1. Variation, heritability and association of yield, fiber and morphological traits in a near long staple upland cotton population

    International Nuclear Information System (INIS)

    Shao, D.; Wang, T.; Zhang, H.; Zhu, J.; Tang, F.

    2016-01-01

    Development of near long staple (NLS) cotton germplasm represents a remarkable improvement in fiber properties of upland genotypes without compromising yield potential. This study aimed to evaluate a NLS population for variability in yield, fiber and morphological traits, investigate heritability and genetic advance of these traits, and analyze the interrelationships among them. The NLS lines exhibited large variation for lint yield per hectare and bolls per plant, while little variation for fiber properties. The highest genotypic (GCV) and phenotypic (PCV) coefficient of variation were recorded by lint yield per hectare (25.10%, 23.00%) followed by bolls per plant (18.88%, 16.38%). High heritability along with high response to selection was documented in plant height, bolls per plant and lint yield per hectare indicating that the additive gene function model in the inheritance of these traits and direct selection can be profitably applied on them. Favourable associations were found among fiber length, strength and fineness in this population. It is concluded that there is a great potential in the NSL population for further enhancing yield while maintaining high fiber quality. (author)

  2. In vitro assessment of three dimensional dense chitosan-based structures to be used as bioabsorbable implants.

    Science.gov (United States)

    Guitian Oliveira, Nuno; Sirgado, Tatiana; Reis, Luís; Pinto, Luís F V; da Silva, Cláudia Lobato; Ferreira, Frederico Castelo; Rodrigues, Alexandra

    2014-12-01

    Chitosan biocompatibility and biodegradability properties make this biopolymer promising for the development of advanced internal fixation devices for orthopedic applications. This work presents a detailed study on the production and characterization of three dimensional (3D) dense, non-porous, chitosan-based structures, with the ability to be processed in different shapes, and also with high strength and stiffness. Such features are crucial for the application of such 3D structures as bioabsorbable implantable devices. The influence of chitosan's molecular weight and the addition of one plasticizer (glycerol) on 3D dense chitosan-based products' biomechanical properties were explored. Several specimens were produced and in vitro studies were performed in order to assess the cytotoxicity of these specimens and their physical behavior throughout the enzymatic degradation experiments. The results point out that glycerol does not impact on cytotoxicity and has a high impact in improving mechanical properties, both elasticity and compressive strength. In addition, human mesenchymal stem/stromal cells (MSC) were used as an ex-vivo model to study cell adhesion and proliferation on these structures, showing promising results with fold increase values in total cell number similar to the ones obtained in standard cell culture flasks. Copyright © 2014 Elsevier Ltd. All rights reserved.

  3. 77 FR 54898 - Certain Polyester Staple Fiber From the People's Republic of China: Final Results of Expedited...

    Science.gov (United States)

    2012-09-06

    ... Fiber From the People's Republic of China: Final Results of Expedited Sunset Review of the Antidumping.... SUMMARY: On May 1, 2012, the Department of Commerce (``the Department'') initiated the first five-year (``sunset'') review of the antidumping duty order on certain polyester staple fiber from the People's...

  4. Animal experiment of memory alloy staples to control the sagittal growth of vertebrates%记忆合金加压钉抑制脊柱矢状面生长的实验研究

    Institute of Scientific and Technical Information of China (English)

    白林; 张巍; 郑国权; 张永刚

    2011-01-01

    目的 探讨记忆合金加压钉植入后非融合性抑制胸段脊柱矢状面生长的作用.方法 将18只幼年雌性山羊随机分为长钉组、短钉组、对照组各6只.长钉组和短钉组通过前路手术在前凸的T6~11胸椎节段植入记忆加压长钉(齿长7 mm)、短钉(齿长4 mm),对照组不予手术.分别于术前、术后3个月行X线片检查,测量Cobb角,对手术前后组间数据及组内自身对照数据进行统计学分析,并计算后凸增加率.大体观察被固定节段脊柱是否融合.结果 全部样本无脱失,均进入结果分析.T6~11 Cobb角,短钉组术前为7.0°±2.3°,术后3个月为12.7°±4.7°,后凸增加率为81.4%;长钉组术前为6.2°±4.0°,术后3个月为14.0°±4.9°,后凸增加率为125.8%;术前及术后长钉短钉两组组间比较,差异均无统计学意义(术前P=0.655;术后P=0.596).将长钉组和短钉组分别与对照组比较,术前差异均无统计学意义(分别为P=0.929和P=0.720);术后差异均有统计学意义(分别为P=0.007和P=0.021).大体观察证实,植入记忆合金加压钉节段脊柱未融合.结论 在山羊胸椎正前方植入记忆合金加压钉可以非融合性控制山羊胸椎的矢状面生长,增加后凸角度.%Objective To present that Nickel-Titanium (NT) memory alloy staples in fusionlessly controlling the growth of the vertebrates in the sagittal plane. Methods Eighteen infant female goats were selected and equally divided into 3 random groups:long staple group, short staple group and blank control group. Five long staple (the legs' length = 7 mm) and five short staple (the legs' length =4 mm) were implanted into each goat in long and short staple groups repecetively by anterior approach, right on the front of the thoracic vertebrae from T6 to T11. The control group was not given any treatment. X-ray examination was performed pre-operatively and post-operatively. Cobb angle of lateral radiograph was measured and the data of Cobb angle

  5. Why Clothes Don't Fall Apart: Tension Transmission in Staple Yarns

    Science.gov (United States)

    Warren, Patrick B.; Ball, Robin C.; Goldstein, Raymond E.

    2018-04-01

    The problem of how staple yarns transmit tension is addressed within abstract models in which the Amontons-Coulomb friction laws yield a linear programing (LP) problem for the tensions in the fiber elements. We find there is a percolation transition such that above the percolation threshold the transmitted tension is in principle unbounded. We determine that the mean slack in the LP constraints is a suitable order parameter to characterize this supercritical state. We argue the mechanism is generic, and in practical terms, it corresponds to a switch from a ductile to a brittle failure mode accompanied by a significant increase in mechanical strength.

  6. 76 FR 60802 - Certain Polyester Staple Fiber From the Republic of Korea and Taiwan: Continuation of Antidumping...

    Science.gov (United States)

    2011-09-30

    ... Staple Fiber From the Republic of Korea and Taiwan: Continuation of Antidumping Duty Orders AGENCY... Republic of Korea (Korea) and Taiwan would likely lead to a continuation or recurrence of dumping and material injury to an industry in the United States, the Department is publishing a notice of continuation...

  7. A comparative evaluation of freeze-dried bone allograft with and without bioabsorbable guided tissue regeneration membrane Healiguide® in the treatment of Grade II furcation defects: A clinical study

    Directory of Open Access Journals (Sweden)

    Deept Jain

    2015-01-01

    Full Text Available Background: Furcation defects represent one of the most demanding therapeutic challenges for periodontal therapy. Various treatment modalities have been tried with different success rates. The present study was undertaken to evaluate the efficacy of freeze-dried bone allograft (FDBA with and without bioabsorbable guided tissue regeneration (GTR membrane Healiguide® in the treatment of Grade II furcation defects. Materials and Methods: Ten patients with bilateral Grade II furcation defects were selected for the study. After phase I therapy, subjects were divided into two arms and treated in a split-mouth design. Ten defects were treated with FDBA alone in the control arm. Ten defects were treated with FDBA in conjunction with bioabsorbable GTR membrane Healiguide® in test arm. Clinical parameters like plaque index, gingival index, vertical probing depth, horizontal probing depth, and relative attachment level (RAL were assessed at baseline, 3 months, and 6 months postoperatively. Results: At 6 months, clinical improvement was seen in both the arms with mean pocket depth reduction of 1.2 ± 1.032 mm and 1.7 ± 0.948 mm and mean horizontal probing depth reduction being 2.1 ± 1.969 mm and 1.6 ± 1.264 mm in control and test arm, respectively. Both surgical procedures resulted in a statistically significant reduction in vertical and horizontal probing depths. Conclusion: Both the arms demonstrated a significant improvement in the probing depth, horizontal furcation depth, and RAL at 6 months postsurgery in the treatment of Grade II furcation defects. However, on the intergroup comparison, there was no statistically significant difference in the results achieved between two arms.

  8. Procedure of brewing alcohol as a staple food: case study of the fermented cereal liquor "Parshot" as a staple food in Dirashe special woreda, southern Ethiopia.

    Science.gov (United States)

    Sunano, Yui

    2016-07-01

    For most brews, alcohol fermentation and lactic fermentation take place simultaneously during the brewing process, and alcohol fermentation can progress smoothly because the propagation of various microorganisms is prevented by lactic fermentation. It is not necessary to cause lactic fermentation with a thing generated naturally and intentionally. The people living in the Dirashe area in southern Ethiopia drink three types of alcoholic beverages that are prepared from cereals. From these alcoholic beverages, parshot is prepared by the addition of plant leaves for lactic fermentation and nech chaka by adding cereal powder for lactic fermentation before alcohol fermentation. People living in the Dirashe area partake of parshot as part of their staple diet. The brewing process used for parshot and a food culture with alcoholic beverages as parts of the staple diet are rare worldwide. This article discusses the significance of using lactic fermentation before alcoholic fermentation and focuses on lactic fermentation in the brewing methods used for the three kinds of alcoholic beverages consumed in the Dirashe area. We initially observed the brewing process and obtained information about the process from the people in that area. Next, we determined the pH and analyzed the lactic acid (g/100 g) and ethanol (g/100 g) content during lactic fermentation of parshot and nech chaka; the ethyl acetate (mg/100 g) and volatile base nitrogen (mg/100 g) content during this period was also analyzed. In addition, we compared the ethanol (g/100 g) content of all three kinds of alcoholic beverages after completion of brewing. The results showed that it was possible to consume large quantities of these alcoholic beverages because of the use of lactic fermentation before alcoholic fermentation, which improved the safety and preservation characteristics of the beverages by preventing the propagation of various microorganisms, improving flavor, and controlling the alcohol level.

  9. The Impact of Nitinol Staples on the Compressive Forces, Contact Area, and Mechanical Properties in Comparison to a Claw Plate and Crossed Screws for the First Tarsometatarsal Arthrodesis.

    Science.gov (United States)

    Aiyer, Amiethab; Russell, Nicholas A; Pelletier, Matthew H; Myerson, Mark; Walsh, William R

    2016-06-01

    Background The optimal fixation method for the first tarsometatarsal arthrodesis remains controversial. This study aimed to develop a reproducible first tarsometatarsal testing model to evaluate the biomechanical performance of different reconstruction techniques. Methods Crossed screws or a claw plate were compared with a single or double shape memory alloy staple configuration in 20 Sawbones models. Constructs were mechanically tested in 4-point bending to 1, 2, and 3 mm of plantar displacement. The joint contact force and area were measured at time zero, and following 1 and 2 mm of bending. Peak load, stiffness, and plantar gapping were determined. Results Both staple configurations induced a significantly greater contact force and area across the arthrodesis than the crossed screw and claw plate constructs at all measurements. The staple constructs completely recovered their plantar gapping following each test. The claw plate generated the least contact force and area at the joint interface and had significantly greater plantar gapping than all other constructs. The crossed screw constructs were significantly stiffer and had significantly less plantar gapping than the other constructs, but this gapping was not recoverable. Conclusions Crossed screw fixation provides a rigid arthrodesis with limited compression and contact footprint across the joint. Shape memory alloy staples afford dynamic fixation with sustained compression across the arthrodesis. A rigid polyurethane foam model provides an anatomically relevant comparison for evaluating the interface between different fixation techniques. Clinical Relevance The dynamic nature of shape memory alloy staples offers the potential to permit early weight bearing and could be a useful adjunctive device to impart compression across an arthrodesis of the first tarsometatarsal joint. Therapeutic, Level V: Bench testing. © 2015 The Author(s).

  10. Effect of hydrocarbon stapling on the properties of alpha-helical antimicrobial peptides isolated from the venom of hymenoptera

    Czech Academy of Sciences Publication Activity Database

    Chapuis, Hubert Jean; Slaninová, Jiřina; Bednárová, Lucie; Monincová, Lenka; Buděšínský, Miloš; Čeřovský, Václav

    2012-01-01

    Roč. 43, č. 5 (2012), s. 2047-2058 ISSN 0939-4451 R&D Projects: GA ČR GA203/08/0536 Institutional research plan: CEZ:AV0Z40550506 Keywords : antimicrobial peptides * stapled peptides * amphipathic helix * CD spectroscopy Subject RIV: CC - Organic Chemistry Impact factor: 3.914, year: 2012

  11. Parafusos bioabsorvíveis na reparação de fraturas experimentais de sesamóides proximais em eqüinos Bioabsorbable screws in the healing of experimentally induced fractures of the proximal sesamoid bone in horses

    Directory of Open Access Journals (Sweden)

    Marcelo Damas Pyles

    2007-10-01

    received bioabsorbable implants (group GI and other four received metallic implants (group GII. Fractures were experimentally induced by means of osteotomy on the midportion of the lateral proximal sesamoid bone. Subsequently, the fragments were fixed with screws and the horses were x-rayed and a fiberglass cast was placed (D0. The cast was removed for radiographic examination on the 30th postoperative day (D30, with radiographic follow up on the 60th (D60, 90th (D90 and 120th (D120 days. Radiographs taken on D30 showed radiodense filling of the fracture site; however, horses from group GII had a less dense fracture line; clinical and radiographic analysis showed a better fracture filling in group GI when compared to Group GII. On D120 radiographic examination revealed radiodense filling of the fracture site in both groups, indicating almost complete fracture healing. However, sclerotic spots were observed around the bioabsorbable implant in GI; on physical examination, horses from group GI were not lame, while horses from group GII had reduced flexion of the metacarpo-phalangeal joint and grade I lameness.

  12. Double quick, double click reversible peptide "stapling".

    Science.gov (United States)

    Grison, Claire M; Burslem, George M; Miles, Jennifer A; Pilsl, Ludwig K A; Yeo, David J; Imani, Zeynab; Warriner, Stuart L; Webb, Michael E; Wilson, Andrew J

    2017-07-01

    The development of constrained peptides for inhibition of protein-protein interactions is an emerging strategy in chemical biology and drug discovery. This manuscript introduces a versatile, rapid and reversible approach to constrain peptides in a bioactive helical conformation using BID and RNase S peptides as models. Dibromomaleimide is used to constrain BID and RNase S peptide sequence variants bearing cysteine (Cys) or homocysteine ( h Cys) amino acids spaced at i and i + 4 positions by double substitution. The constraint can be readily removed by displacement of the maleimide using excess thiol. This new constraining methodology results in enhanced α-helical conformation (BID and RNase S peptide) as demonstrated by circular dichroism and molecular dynamics simulations, resistance to proteolysis (BID) as demonstrated by trypsin proteolysis experiments and retained or enhanced potency of inhibition for Bcl-2 family protein-protein interactions (BID), or greater capability to restore the hydrolytic activity of the RNAse S protein (RNase S peptide). Finally, use of a dibromomaleimide functionalized with an alkyne permits further divergent functionalization through alkyne-azide cycloaddition chemistry on the constrained peptide with fluorescein, oligoethylene glycol or biotin groups to facilitate biophysical and cellular analyses. Hence this methodology may extend the scope and accessibility of peptide stapling.

  13. Stapled Voltage-Gated Calcium Channel (CaV) α-Interaction Domain (AID) Peptides Act As Selective Protein-Protein Interaction Inhibitors of CaV Function.

    Science.gov (United States)

    Findeisen, Felix; Campiglio, Marta; Jo, Hyunil; Abderemane-Ali, Fayal; Rumpf, Christine H; Pope, Lianne; Rossen, Nathan D; Flucher, Bernhard E; DeGrado, William F; Minor, Daniel L

    2017-06-21

    For many voltage-gated ion channels (VGICs), creation of a properly functioning ion channel requires the formation of specific protein-protein interactions between the transmembrane pore-forming subunits and cystoplasmic accessory subunits. Despite the importance of such protein-protein interactions in VGIC function and assembly, their potential as sites for VGIC modulator development has been largely overlooked. Here, we develop meta-xylyl (m-xylyl) stapled peptides that target a prototypic VGIC high affinity protein-protein interaction, the interaction between the voltage-gated calcium channel (Ca V ) pore-forming subunit α-interaction domain (AID) and cytoplasmic β-subunit (Ca V β). We show using circular dichroism spectroscopy, X-ray crystallography, and isothermal titration calorimetry that the m-xylyl staples enhance AID helix formation are structurally compatible with native-like AID:Ca V β interactions and reduce the entropic penalty associated with AID binding to Ca V β. Importantly, electrophysiological studies reveal that stapled AID peptides act as effective inhibitors of the Ca V α 1 :Ca V β interaction that modulate Ca V function in an Ca V β isoform-selective manner. Together, our studies provide a proof-of-concept demonstration of the use of protein-protein interaction inhibitors to control VGIC function and point to strategies for improved AID-based Ca V modulator design.

  14. Maternal Consumption of Non-Staple Food in the First Trimester and Risk of Neural Tube Defects in Offspring

    Directory of Open Access Journals (Sweden)

    Meng Wang

    2015-04-01

    Full Text Available To study the associations between maternal consumption of non-staple food in the first trimester and risk of neural tube defects (NTDs in offspring. Data collected from a hospital-based case-control study conducted between 2006 and 2008 in Shandong/Shanxi provinces including 459 mothers with NTDs-affected births and 459 mothers without NTDs-affected births. Logistic regression models were used to examine the associations between maternal consumption of non-staple food in the first trimester and risk of NTDs in offspring. The effects were evaluated by odds ratio (OR and 95% confidence intervals (95% CIs with SAS9.1.3.software. Maternal consumption of milk, fresh fruits and nuts in the first trimester were protective factors for total NTDs. Compared with consumption frequency of ˂1 meal/week, the ORs for milk consumption frequency of 1–2, 3–6, ≥7 meals/week were 0.50 (95% CI: 0.28–0.88, 0.56 (0.32–0.99, and 0.59 (0.38–0.90, respectively; the ORs for fresh fruits consumption frequency of 1–2, 3–6, ≥7 meals/week were 0.29 (95% CI: 0.12–0.72, 0.22 (0.09–0.53, and 0.32 (0.14–0.71, respectively; the ORs for nuts consumption frequency of 1–2, 3–6, ≥7 meals/week were 0.60 (95% CI: 0.38–0.94, 0.49 (0.31–0.79, and 0.63 (0.36–1.08, respectively. Different effects of above factors on NTDs were found for subtypes of anencephaly and spina bifida. Maternal non-staple food consumption of milk, fresh fruits and nuts in the first trimester was associated with reducing NTDs risk in offspring.

  15. Delayed Tibial Osteomyelitis after Anterior Cruciate Ligament Reconstruction with Hamstrings Autograft and Bioabsorbable Interference Screw: A Case Report and Review of the Literature

    Directory of Open Access Journals (Sweden)

    Kevin S. Weiss

    2017-01-01

    Full Text Available Osteomyelitis following arthroscopically assisted anterior cruciate ligament (ACL reconstruction has rarely been reported in the literature. We report a case of a 20-year-old female who had delayed tibial osteomyelitis and a pretibial cyst with culture-positive, oxacillin sensitive Staphylococcus epidermidis 15 months after an ACL reconstruction with hamstring autograft. Soft tissue fixation within the tibial tunnel was with a poly-L-D-lactic acid (PLDLA bioabsorbable interference screw. The patient underwent surgical treatment with curettage, debridement, hardware removal, and bone grafting of the tibial tunnel followed by a course of intravenous antibiotics. Arthroscopic evaluation demonstrated an intact ACL graft without any evidence of intra-articular infection. The patient returned to collegiate athletics without any complications. While the most common biologic complications include pretibial cysts, granuloma formation, tunnel widening, and inflammatory reactions, infection is exceedingly rare. Late infection and osteomyelitis are also rare but can occur and should be considered in the differential diagnosis.

  16. Individual surgeon is an independent risk factor for leak after double-stapled colorectal anastomosis: An institutional analysis of 800 patients.

    Science.gov (United States)

    García-Granero, Eduardo; Navarro, Francisco; Cerdán Santacruz, Carlos; Frasson, Matteo; García-Granero, Alvaro; Marinello, Franco; Flor-Lorente, Blas; Espí, Alejandro

    2017-11-01

    Our aim was to assess whether the individual surgeon is an independent risk factor for anastomotic leak in double-stapled colorectal anastomosis after left colon and rectal cancer resection. This retrospective analysis of a prospectively collected database consists of a consecutive series of 800 patients who underwent an elective left colon and rectal resection with a colorectal, double-stapled anastomosis between 1993 and 2009 in a specialized colorectal unit of a tertiary hospital with 7 participating surgeons. The main outcome variable was anastomotic leak, defined as leak of luminal contents from a colorectal anastomosis between 2 hollow viscera diagnosed radiologically, clinically, endoscopically, or intraoperatively. Pelvic abscesses were also considered to be an anastomotic leak. Radiologic examination was performed when there was clinical suspicion of leak. Anastomotic leak occurred in 6.1% of patients, of which 33 (67%) were treated operatively, 6 (12%) with radiologic drains, and 10 (21%) by medical treatment. Postoperative mortality rate was 2.9% for the whole group of 800 patients. In patients with anastomotic leak, mortality rate increased up to 16% vs 2.0% in patients without anastomotic leak (P leak. The surgeon was the most important factor (mean odds ratio 4.9; range 1.0 to 13.5). The variance of anastomotic leak between the different surgeons was 0.56 in the logit scale. The individual surgeon is an independent risk factor for leakage in double-stapled, colorectal, end-to-end anastomosis after oncologic left-sided colorectal resection. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. The growing importance of staple foods and condiments used as ingredients in the food industry and implications for large-scale food fortification programs in Southeast Asia.

    Science.gov (United States)

    Spohrer, Rebecca; Larson, Melanie; Maurin, Clémence; Laillou, Arnaud; Capanzana, Mario; Garrett, Greg S

    2013-06-01

    Food fortification is a viable strategy to improve the nutritional status of populations. In Southeast Asia, recent growth and consolidation of the food industry provides an opportunity to explore whether certain widely consumed processed foods could contribute to micronutrient status if they are made with adequately fortified staples and condiments. To estimate the potential contribution certain processed foods can make to micronutrient intake in Southeast Asia if they are made with fortified staples and condiments; e.g., via the inclusion of iodized salt in various processed foods in the Philippines, fortified wheat flour in instant noodles in Indonesia, and fortified vegetable oil in biscuits in Vietnam. For Indonesia, the Philippines, and Vietnam, a review of consumption trends, relevant policies, and industry practices was conducted using publicly available sources,food industry market data and research reports, and oral communication. These informed the estimates of the proportion of the Recommended Nutrient Intake (RNI) that could be delivered via select processed foods. In the Philippines, Indonesia, and Vietnam, the processed food industry is not always required to use fortified staples and condiments. In the Philippines, dried salted fish with iodized salt would provide 64% to 85% of the iodine RNI for women of reproductive age and 107% to 141% of the iodine RNI for children 1 to 6 years of age. In Indonesia, a 75-g pack of instant noodles (a highly consumed product) with fortified wheat flour would provide 45% to 51% of the iron RNI for children 4 to 6 years of age and 10% to 11% of the iron RNI for women of reproductive age. In Vietnam, biscuits containing vegetable oil are increasingly popular. One 35-g biscuit serving with fortified vegetable oil would provide 13% to 18% of the vitamin A RNI for children 4 to 6 years of age and 12% to 17% of the vitamin A RNI for women of reproductive age. Ensuring that fortified staples and condiments such as flour

  18. A Randomized Study Comparing Outcomes of Stapled and Hand-Sutured Anastomoses in Patients Undergoing Open Gastrointestinal Surgery

    OpenAIRE

    Chandramohan, S. M.; Gajbhiye, Raj Narenda; Agwarwal, Anil; Creedon, Erin; Schwiers, Michael L.; Waggoner, Jason R.; Tatla, Daljit

    2012-01-01

    Although stapling is an alternative to hand-suturing in gastrointestinal surgery, recent trials specifically designed to evaluate differences between the two in surgery time, anastomosis time, and return to bowel activity are lacking. This trial compared the outcomes of the two in subjects undergoing open gastrointestinal surgery. Adult subjects undergoing emergency or elective surgery requiring a single gastric, small, or large bowel anastomosis were enrolled into this open-label, prospectiv...

  19. Risk Factors for Dehiscence of Stapled Functional End-to-End Intestinal Anastomoses in Dogs: 53 Cases (2001-2012).

    Science.gov (United States)

    Snowdon, Kyle A; Smeak, Daniel D; Chiang, Sharon

    2016-01-01

    To identify risk factors for dehiscence in stapled functional end-to-end anastomoses (SFEEA) in dogs. Retrospective case series. Dogs (n = 53) requiring an enterectomy. Medical records from a single institution for all dogs undergoing an enterectomy (2001-2012) were reviewed. Surgeries were included when gastrointestinal (GIA) and thoracoabdominal (TA) stapling equipment was used to create a functional end-to-end anastomosis between segments of small intestine or small and large intestine in dogs. Information regarding preoperative, surgical, and postoperative factors was recorded. Anastomotic dehiscence was noted in 6 of 53 cases (11%), with a mortality rate of 83%. The only preoperative factor significantly associated with dehiscence was the presence of inflammatory bowel disease (IBD). Surgical factors significantly associated with dehiscence included the presence, duration, and number of intraoperative hypotensive periods, and location of anastomosis, with greater odds of dehiscence in anastomoses involving the large intestine. IBD, location of anastomosis, and intraoperative hypotension are risk factors for intestinal anastomotic dehiscence after SFEEA in dogs. Previously suggested risk factors (low serum albumin concentration, preoperative septic peritonitis, and intestinal foreign body) were not confirmed in this study. © Copyright 2015 by The American College of Veterinary Surgeons.

  20. Routine intraoperative leak testing for sleeve gastrectomy: is the leak test full of hot air?

    Science.gov (United States)

    Bingham, Jason; Lallemand, Michael; Barron, Morgan; Kuckelman, John; Carter, Preston; Blair, Kelly; Martin, Matthew

    2016-05-01

    Staple line leak after sleeve gastrectomy (SG) is a rare but dreaded complication with a reported incidence of 0% to 8%. Many surgeons routinely test the staple line with an intraoperative leak test (IOLT), but there is little evidence to validate this practice. In fact, there is a theoretical concern that the leak test may weaken the staple line and increase the risk of a postop leak. Retrospective review of all SGs performed over a 7-year period was conducted. Cases were grouped by whether an IOLT was performed, and compared for the incidence of postop staple line leaks. The ability of the IOLT for identifying a staple line defect and for predicting a postoperative leak was analyzed. Five hundred forty-two SGs were performed between 2007 and 2014. Thirteen patients (2.4%) developed a postop staple line leak. The majority of patients (n = 494, 91%) received an IOLT, including all 13 patients (100%) who developed a subsequent clinical leak. There were no (0%) positive IOLTs and no additional interventions were performed based on the IOLT. The IOLT sensitivity and positive predictive value were both 0%. There was a trend, although not significant, to increase leak rates when a routine IOLT was performed vs no routine IOLT (2.6% vs 0%, P = .6). The performance of routine IOLT after SG provided no actionable information, and was negative in all patients who developed a postoperative leak. The routine use of an IOLT did not reduce the incidence of postop leak, and in fact was associated with a higher leak rate after SG. Published by Elsevier Inc.

  1. A bioabsorbable membrane (Seprafilm®) may prevent postoperative mediastinal adhesions following mediastinoscopy: an experimental study in rats.

    Science.gov (United States)

    Büyükkale, Songül; Çıtak, Necati; İşgörücü, Özgür; Sayar, Adnan

    2015-01-01

    The aim of this experimental study was to investigate the anti-adhesion property of a bioabsorbable membrane following mediastinoscopy in a rat model. The study was conducted in 20 male Sprague-Dawley rats. Mediastinoscopy was performed all of them. Rats were divided into two groups; control group (n=10); mediastinoscopy alone, study group (n=10); mediastinoscopy and sodiumhyaluronate-carboxymethlycellulose film (Seprafilm®; Genzyme Corporation, Cambridge, Mass. USA). It was used to the mediastinal surface at the end of the surgical procedure in study group. Re-mediastinoscopy was performed after 7 days. Adhesion and vascularity grade description scores were analyzed. The parameters evaluated were presence of polymorhphonucleer leucocyte, macrophage, lymphocyte, fibroblasts, edema, neovascularisation, collagenisation, and foreing body reaction. All the rats survived uneventfully until being sacrificed without any postoperative complications. The mean adhesion score was found to be significantly higher in control group (n=2.5±0.5) compared with study group (n=1.0±0.1) (P=0.007). Vascularity grade description score was significantly higher in control group (n=2.3±0.6) than in study group (n=1.4±0.6) (P=0.009). There were no statistical differences between the groups with regard to edema, lymphocyte and macrophage infiltration, fibroblast proliferation and foreign body reactions (P>0.05). The used of Seprafilm® during the primary procedure can reduce to the mediastinal adhesions. However, further studies are required to assess the precise impact of the anti-adhesive agents on adhesion.

  2. Bioabsorbable drug-eluting vascular scaffold for the treatment of coronary in-stent restenosis: A two center registry

    International Nuclear Information System (INIS)

    Moscarella, Elisabetta; Varricchio, Attilio; Stabile, Eugenio; Franzone, Anna; Granata, Francesco; Rapacciuolo, Antonio; Galasso, Gennaro; Capozzolo, Claudia; Cirillo, Plinio

    2015-01-01

    Background/purpose: Coronary in-stent restenosis (ISR) is a clinical problem for which a satisfactory solution has not been found yet. Bioabsorbable drug eluting vascular scaffolds (BVSs) provide transient vessel scaffolding combined with prolonged drug delivery capability. The aim of this study was to investigate the safety of BVS for the treatment of coronary ISR. Methods/materials: Between January 2013 and June 2013, 27 patients (31 lesions), presenting with either stable or unstable angina due to coronary ISR, were enrolled in a single arm, prospective, open label registry. Primary end point was the occurrence of target vessel revascularization (TVR) at 12 months. Secondary end point was the composite of death, myocardial infarction and TVR at 12 months. Results: A diffuse ISR pattern was present in 70% of the lesions; mean lesion length was 34.6 ± 15. BVS was successfully implanted in all patients with no in hospital MACE. At twelve months of follow up, MACE rate was 18.5%. One patient died for non-cardiac reason, one patient died due to a possible stent thrombosis and TVR was necessary in 3 patients (11.1%). Conclusions: Our data suggest that BVS is safe and technically feasible for treatment of long and diffuse coronary ISR. These data could be considered hypothesis generator for a randomized clinical trial. - Highlights: • A safe therapeutic option for the treatment of diffuse ISR; • Technically feasible; • Associated to a low rate of restenosis recurrence at nine month.

  3. Bioabsorbable drug-eluting vascular scaffold for the treatment of coronary in-stent restenosis: A two center registry

    Energy Technology Data Exchange (ETDEWEB)

    Moscarella, Elisabetta [Division of Cardiology, Seconda Università degli studi di Napoli, AO Dei cColli, PO Monaldi (Italy); Varricchio, Attilio [Division of Cardiology, Department of Advanced Biomedical Sciences, University of Napoli “Federico II”, Napoli (Italy); Stabile, Eugenio, E-mail: geko50@hotmail.com [Laboratory of Invasive Cardiology, Dipartimento di Cardiologia, Presidio Ospedaliero “Monaldi”, Azienda Ospedaliera “Dei Colli”, Napoli (Italy); Franzone, Anna [Laboratory of Invasive Cardiology, Dipartimento di Cardiologia, Presidio Ospedaliero “Monaldi”, Azienda Ospedaliera “Dei Colli”, Napoli (Italy); Granata, Francesco [Division of Cardiology, Seconda Università degli studi di Napoli, AO Dei cColli, PO Monaldi (Italy); Rapacciuolo, Antonio; Galasso, Gennaro [Laboratory of Invasive Cardiology, Dipartimento di Cardiologia, Presidio Ospedaliero “Monaldi”, Azienda Ospedaliera “Dei Colli”, Napoli (Italy); Capozzolo, Claudia [Division of Cardiology, Department of Advanced Biomedical Sciences, University of Napoli “Federico II”, Napoli (Italy); Cirillo, Plinio [Laboratory of Invasive Cardiology, Dipartimento di Cardiologia, Presidio Ospedaliero “Monaldi”, Azienda Ospedaliera “Dei Colli”, Napoli (Italy); and others

    2015-10-15

    Background/purpose: Coronary in-stent restenosis (ISR) is a clinical problem for which a satisfactory solution has not been found yet. Bioabsorbable drug eluting vascular scaffolds (BVSs) provide transient vessel scaffolding combined with prolonged drug delivery capability. The aim of this study was to investigate the safety of BVS for the treatment of coronary ISR. Methods/materials: Between January 2013 and June 2013, 27 patients (31 lesions), presenting with either stable or unstable angina due to coronary ISR, were enrolled in a single arm, prospective, open label registry. Primary end point was the occurrence of target vessel revascularization (TVR) at 12 months. Secondary end point was the composite of death, myocardial infarction and TVR at 12 months. Results: A diffuse ISR pattern was present in 70% of the lesions; mean lesion length was 34.6 ± 15. BVS was successfully implanted in all patients with no in hospital MACE. At twelve months of follow up, MACE rate was 18.5%. One patient died for non-cardiac reason, one patient died due to a possible stent thrombosis and TVR was necessary in 3 patients (11.1%). Conclusions: Our data suggest that BVS is safe and technically feasible for treatment of long and diffuse coronary ISR. These data could be considered hypothesis generator for a randomized clinical trial. - Highlights: • A safe therapeutic option for the treatment of diffuse ISR; • Technically feasible; • Associated to a low rate of restenosis recurrence at nine month.

  4. Brazil's staple food and incident diabetes.

    Science.gov (United States)

    Rosa, Maria Luiza Garcia; Falcão, Paula M; Yokoo, Edna Massae; da Cruz Filho, Rubens Antunes; Alcoforado, Veronica Miranda; de Souza, Barbara da Silva Nalin; Pinto, Fernanda Neves; Nery, Aline Barreto

    2014-03-01

    The aim of this study was to investigate the association of Brazil's staple food, rice, beans and manioc, and the incidence of type 2 diabetes mellitus type 2 (T2DM) in adults assisted by a Brazilian Family Doctor Program (FDP). The baseline information was collected on visits to 13 units of the FDP from July 2006 to December 2007 (CAMELIA Study). The units were revisited by trained researchers between July and December 2011, who reviewed medical records of all participants of the baseline. Biochemical, anthropometrical and blood pressure measurements, new diagnoses, and medical prescriptions were collected. Individuals ages ≥20 y, who were non-diabetic at baseline were included (N = 409). Food consumption was estimated using a validated semi-quantitative food frequency questionnaire. Incident of diabetes was classified according to fasting serum glucose (≥126 mg/dL), individual's use of antidiabetic drugs, and/or diagnosis of diabetes described in the medical record. Individuals who were negative at baseline and also were negative for the above conditions were classified as non-diabetics. Individuals who developed T2DM (N = 30) reported higher consumption of red meat and beans and less consumption of cassava flour, independent of the interval between visits and other potential confounding variables. The cassava flour showed a protective effect (relative risk, 0.910; 95% confidence interval, 0.842-0.982). The consumption of cassava flour, a low-cost product, could be considered in diets for the prevention and control of diabetes. The hypothesis must be investigated in cohorts from different populations and tested in randomized controlled trials. Copyright © 2014 Elsevier Inc. All rights reserved.

  5. A Systematic Review of Perennial Staple Crops Literature Using Topic Modeling and Bibliometric Analysis

    Science.gov (United States)

    2016-01-01

    Research on perennial staple crops has increased in the past ten years due to their potential to improve ecosystem services in agricultural systems. However, multiple past breeding efforts as well as research on traditional ratoon systems mean there is already a broad body of literature on perennial crops. In this review, we compare the development of research on perennial staple crops, including wheat, rice, rye, sorghum, and pigeon pea. We utilized the advanced search capabilities of Web of Science, Scopus, ScienceDirect, and Agricola to gather a library of 914 articles published from 1930 to the present. We analyzed the metadata in the entire library and in collections of literature on each crop to understand trends in research and publishing. In addition, we applied topic modeling to the article abstracts, a type of text analysis that identifies frequently co-occurring terms and latent topics. We found: 1.) Research on perennials is increasing overall, but individual crops have each seen periods of heightened interest and research activity; 2.) Specialist journals play an important role in supporting early research efforts. Research often begins within communities of specialists or breeders for the individual crop before transitioning to a more general scientific audience; 3.) Existing perennial agricultural systems and their domesticated crop material, such as ratoon rice systems, can provide a useful foundation for breeding efforts, accelerating the development of truly perennial crops and farming systems; 4.) Primary research is lacking for crops that are produced on a smaller scale globally, such as pigeon pea and sorghum, and on the ecosystem service benefits of perennial agricultural systems. PMID:27213283

  6. An endoscopic mucosal grading system is predictive of leak in stapled rectal anastomoses.

    Science.gov (United States)

    Sujatha-Bhaskar, Sarath; Jafari, Mehraneh D; Hanna, Mark; Koh, Christina Y; Inaba, Colette S; Mills, Steven D; Carmichael, Joseph C; Nguyen, Ninh T; Stamos, Michael J; Pigazzi, Alessio

    2018-04-01

    Anastomotic leak is a devastating postoperative complication following rectal anastomoses associated with significant clinical and oncological implications. As a result, there is a need for novel intraoperative methods that will help predict anastomotic leak. From 2011 to 2014, patient undergoing rectal anastomoses by colorectal surgeons at our institution underwent prospective application of intraoperative flexible endoscopy with mucosal grading. Retrospective review of patient medical records was performed. After creation of the colorectal anastomosis, application of a three-tier endoscopic mucosal grading system occurred. Grade 1 was defined as circumferentially normal appearing peri-anastomotic mucosa. Grade 2 was defined as ischemia or congestion involving 30% of the colon or rectal mucosa or ischemia/congestion involving both sides of the staple line. From 2011 to 2014, a total of 106 patients were reviewed. Grade 1 anastomoses were created in 92 (86.7%) patients and Grade 2 anastomoses were created in 10 (9.4%) patients. All 4 (3.8%) Grade 3 patients underwent immediate intraoperative anastomosis takedown and re-creation, with subsequent re-classification as Grade 1. Demographic and comorbidity data were similar between Grade 1 and Grade 2 patients. Anastomotic leak rate for the entire cohort was 12.2%. Grade 1 patients demonstrated a leak rate of 9.4% (9/96) and Grade 2 patients demonstrated a leak rate of 40% (4/10). Multivariate logistic regression associated Grade 2 classification with an increased risk of anastomotic leak (OR 4.09, 95% CI 1.21-13.63, P = 0.023). Endoscopic mucosal grading is a feasible intraoperative technique that has a role following creation of a rectal anastomosis. Identification of a Grade 2 or Grade 3 anastomosis should provoke strong consideration for immediate intraoperative revision.

  7. Greenhouse gas emissions and reactive nitrogen releases during the life-cycles of staple food production in China and their mitigation potential

    Energy Technology Data Exchange (ETDEWEB)

    Xia, Longlong [State Key Laboratory of Soil and Sustainable Agriculture, Institute of Soil Science, Chinese Academy of Sciences, Nanjing 210008 (China); University of Chinese Academy of Sciences, Beijing 100049 (China); Ti, Chaopu [State Key Laboratory of Soil and Sustainable Agriculture, Institute of Soil Science, Chinese Academy of Sciences, Nanjing 210008 (China); Li, Bolun [State Key Laboratory of Soil and Sustainable Agriculture, Institute of Soil Science, Chinese Academy of Sciences, Nanjing 210008 (China); University of Chinese Academy of Sciences, Beijing 100049 (China); Xia, Yongqiu [State Key Laboratory of Soil and Sustainable Agriculture, Institute of Soil Science, Chinese Academy of Sciences, Nanjing 210008 (China); Yan, Xiaoyuan, E-mail: yanxy@issas.ac.cn [State Key Laboratory of Soil and Sustainable Agriculture, Institute of Soil Science, Chinese Academy of Sciences, Nanjing 210008 (China)

    2016-06-15

    Life-cycle analysis of staple food (rice, flour and corn-based fodder) production and assessments of the associated greenhouse gas (GHG) and reactive nitrogen (Nr) releases, from environmental and economic perspectives, help to develop effective mitigation options. However, such evaluations have rarely been executed in China. We evaluated the GHG and Nr releases per kilogram of staple food production (carbon and Nr footprints) and per unit of net economic benefit (CO{sub 2-NEB} and Nr{sub -NEB}), and explored their mitigation potential. Carbon footprints of food production in China were obviously higher than those in some developed countries. There was a high spatial variation in the footprints, primarily attributable to differences in synthetic N use (or CH{sub 4} emissions) per unit of food production. Provincial carbon footprints had a significant linear relationship with Nr footprints, attributed to large contribution of N fertilizer use to both GHG and Nr releases. Synthetic N fertilizer applications and CH{sub 4} emissions dominated the carbon footprints, while NH{sub 3} volatilization and N leaching were the main contributors to the Nr footprints. About 564 (95% uncertainty range: 404–701) Tg CO{sub 2} eq GHG and 10 (7.4–12.4) Tg Nr-N were released every year during 2001–2010 from staple food production. This caused the total damage costs of 325 (70–555) billion ¥, equivalent to nearly 1.44% of the Gross Domestic Product of China. Moreover, the combined damage costs and economic input costs, accounted for 66%-80% of the gross economic benefit generated from food production. A reduction of 92.7 Tg CO{sub 2} eq yr{sup −1} and 2.2 Tg Nr-N yr{sup −1} could be achieved by reducing synthetic N inputs by 20%, increasing grain yields by 5% and implementing off-season application of straw and mid-season drainage practices for rice cultivation. In order to realize these scenarios, an ecological compensation scheme should be established to incentivize

  8. Greenhouse gas emissions and reactive nitrogen releases during the life-cycles of staple food production in China and their mitigation potential

    International Nuclear Information System (INIS)

    Xia, Longlong; Ti, Chaopu; Li, Bolun; Xia, Yongqiu; Yan, Xiaoyuan

    2016-01-01

    Life-cycle analysis of staple food (rice, flour and corn-based fodder) production and assessments of the associated greenhouse gas (GHG) and reactive nitrogen (Nr) releases, from environmental and economic perspectives, help to develop effective mitigation options. However, such evaluations have rarely been executed in China. We evaluated the GHG and Nr releases per kilogram of staple food production (carbon and Nr footprints) and per unit of net economic benefit (CO 2-NEB and Nr -NEB ), and explored their mitigation potential. Carbon footprints of food production in China were obviously higher than those in some developed countries. There was a high spatial variation in the footprints, primarily attributable to differences in synthetic N use (or CH 4 emissions) per unit of food production. Provincial carbon footprints had a significant linear relationship with Nr footprints, attributed to large contribution of N fertilizer use to both GHG and Nr releases. Synthetic N fertilizer applications and CH 4 emissions dominated the carbon footprints, while NH 3 volatilization and N leaching were the main contributors to the Nr footprints. About 564 (95% uncertainty range: 404–701) Tg CO 2 eq GHG and 10 (7.4–12.4) Tg Nr-N were released every year during 2001–2010 from staple food production. This caused the total damage costs of 325 (70–555) billion ¥, equivalent to nearly 1.44% of the Gross Domestic Product of China. Moreover, the combined damage costs and economic input costs, accounted for 66%-80% of the gross economic benefit generated from food production. A reduction of 92.7 Tg CO 2 eq yr −1 and 2.2 Tg Nr-N yr −1 could be achieved by reducing synthetic N inputs by 20%, increasing grain yields by 5% and implementing off-season application of straw and mid-season drainage practices for rice cultivation. In order to realize these scenarios, an ecological compensation scheme should be established to incentivize farmers to gradually adopt knowledge

  9. Anastomotic leakage after low anterior resection for rectal cancer: comparison of stapled versus compression anastomosis.

    Science.gov (United States)

    Dauser, Bernhard; Braunschmid, Tamara; Ghaffari, Shahbaz; Riss, Stefan; Stift, Anton; Herbst, Friedrich

    2013-10-01

    Surgical technique and perioperative management in rectal cancer surgery have been substantially improved and standardized during the last decades. However, anastomotic leakage following low anterior resection still is a significant problem. Based on animal experimental data of improved healing of compression anastomosis, we hypothesized that a compression anastomotic device might improve healing rates of the highest-risk anastomoses. All low anterior resections for rectal cancer performed or directly supervised by the senior author between January 2004 and June 2012 were analyzed. Only patients with a stapled or compression anastomosis located within 6 cm from the anal verge were included. Until December 2008, circular staplers were employed, while since January 2009, a novel compression anastomotic device was used for rectal reconstruction exclusively. Out of 197 patients operated for rectal cancer, a total of 96 (34 females, 35.4 %) fulfilled inclusion criteria. Fifty-eight (60.4 %) were reconstructed with circular staplers and 38 (39.6 %) using a compression anastomotic device. Significantly, more laparoscopic procedures were recorded in the compression anastomosis group, but distribution of gender, age, body mass index, American Society of Anaesthesiologists score, rate of preoperative radiotherapy, tumor staging, or stoma diversion rate were similar. Anastomotic leakage was observed in seven cases (7/58, 12.1 %) in the stapled and twice (2/38, 5.3 %) in the compression anastomosis group (p = 0.26). In this series, rectal reconstruction following low anterior resection using a novel compression anastomotic device was safe and (at least) equally effective compared to traditional circular staplers concerning leak rate.

  10. Adenocarcinoma in the anal canal after ileal pouch-anal anastomosis for familial adenomatous polyposis using a double-stapled technique: report of two cases

    NARCIS (Netherlands)

    Vrouenraets, Bart C.; van Duijvendijk, Peter; Bemelman, Willem A.; Offerhaus, G. Johan A.; Slors, J. Frederik M.

    2004-01-01

    Restorative proctocolectomy with an ileal pouch-anal anastomosis is thought to abolish the risk of colorectal adenoma development in patients suffering from familial adenomatous polyposis. Both after mucosectomy with a handsewn anastomosis and after a double-stapled anastomosis, rectal mucosa is

  11. “Al-Musaqah” and Sharia Agribusiness System: An Alternative Way to Meet Staple Food Self-Sufficiency in Contemporary Indonesia

    Directory of Open Access Journals (Sweden)

    Ujang Maman Maman

    2017-12-01

    Full Text Available The concept of al-musaqah appears in Islamic history when Prophet Muhammad conquered the fertile farmland surrounding Khaibar, abandoned by Jews as the original owner of the land. The concept of al-musaqoh also appears in fiqh deliberations, in which it is a partnership between tenants and land owners. By deepening literature, the concept of al-musaqah is part of sharia agribusiness system that could be an alternative partnerships and farmer institution in meeting staple food needs. The alternative concept is very necessary since Indonesia has been facing the issue of agricultural land conversion and difficulty to form sustainable food agriculture area (SFAA. For the implementation of al-musaqoh, the Government should systematically form the SFAA on the state owned land, and estabilish its institution to manage SFAA in the central and regional level. Then, the SFAA management implement al-musaqoh partnership with farmer groups. By the concept, the Government would be able to control staple food procurement and distribution  to achieve food self-sufficiency which is profitable for farmers and non-farmers. However, the implementation is based on the view that the provision of basic needs should not be left to market mechanism.

  12. Radiographic findings of post-operative double stapled trans anal rectal resection (STARR) in patient with obstructed defecation syndrome (ODS).

    Science.gov (United States)

    Grassi, Roberto; Romano, Stefania; Micera, Osvaldo; Fioroni, Claudio; Boller, Brigitta

    2005-03-01

    Longo's procedure of double stapled trans anal rectal resection (STARR) has been evocated as surgical treatment of the obstructed defecation syndrome (ODS) in patients with rectal mucosal prolapse. The aim of this study was to investigate the post-interventional findings of this technique, to help radiologist in knowledge of the changed morphology of the rectal lumen, also in attempt to recognize some potential related complications.

  13. Quality of Life after Stapled Hemorrhoidopexy: A Prospective Observational Study

    Directory of Open Access Journals (Sweden)

    Pankaj Kumar Garg

    2013-01-01

    Full Text Available Objective. The objective of the study was to assess the change in quality of life (QOL of patients undergoing stapled hemorrhoidopexy (SH using WHO Quality of Life-BREF (WHOQOL-BREF questionnaire. Methods. The study sample comprised patients with symptomatic II, III, and IV degree hemorrhoids, undergoing SH. The patients were asked to complete WHOQOL-BREF questionnaire before and one month following the surgery. Result. There were 20 patients in the study group. The postoperative pain score measured by visual analogue scale at six hours postoperatively was at 24 hours. The items in the WHOQOL-BREF had high-internal consistency or reliability as shown by high Cronbach's alpha coefficient which was 0.82 and 0.90 for pre- and postoperative questionnaires. There was significant improvement in the overall perception of QOL and health, and in physical and psychological domains. There was modest improvement in environmental domain, while no change was noted in social domain. Conclusion. SH improved the quality of life of patients treated for hemorrhoids.

  14. Mineral biofortification strategies for food staples: the example of common bean.

    Science.gov (United States)

    Blair, Matthew W

    2013-09-04

    Common bean is the most important directly consumed legume, especially in the least developed countries of Africa (e.g., Burundi, Democratic Republic of Congo, Rwanda, and Uganda) and Latin America (e.g., Guatemala, Nicaragua, and El Salvador). Biofortification is the process of improving staple crops for mineral or vitamin content as a way to address malnutrition in developing countries. The main goals of mineral biofortification have been to increase the concentration of iron or zinc in certain major cereals and legumes. In humans, iron is essential for preventing anemia and for the proper functioning of many metabolic processes, whereas zinc is essential for adequate growth and for resistance to gastroenteric and respiratory infections, especially in children. This paper outlines the advantages and needs of mineral biofortification in common bean, starting with the steps of breeding for the trait such as germplasm screening, inheritance, physiological, or bioavailability studies and finishing with product development in the form of new biofortified varieties.

  15. Enveloping bioabsorbable polyglycolide membrane and immobilization in Achilles tendon repair: A comparative experimental study on rabbits.

    Science.gov (United States)

    Pihlajamäki, Harri; Tynninen, Olli; Karjalainen, Pertti; Rokkanen, Pentti

    2008-02-01

    Using qualitative and histoquantitative methods, we investigated the effect of immobilization versus nonimmobilization on the biodegradation process, implant-tissue interaction, and scar formation after enveloping a rejoined rabbit Achilles tendon with a self-reinforced polyglycolide (SR-PGA) membrane. The soleus and gastrocnemius tendons of the right hind legs of 40 rabbits were transected. After suturing the ends, the seam was enveloped with the bioabsorbable membrane. Twenty ankles were immobilized with cast, 20 remained nonimmobilized. All nonoperated left ankles served as intact controls. During the follow-up of 3, 6, 12, and 24 weeks, scar formation, tissue response, and membrane biodegradation were studied histologically and histomorphometrically. The amount of scar tissue, highest at 3 weeks, gradually approached intact controls. SR-PGA degradation in both cast and noncast specimens was near complete by 24 weeks. Signs of an inflammatory process were most prominent at 3 weeks and diminished gradually by 24 weeks. No significant difference between cast and noncast specimens was noted at any time point regarding the amount of scar tissue, degradation process of PGA, or intensity of inflammatory reaction. In the present experimental setting, cast immobilization influenced neither scar formation nor speed of degradation during reunion of transected Achilles tendon ends as compared with nonimmobilization. No differences in the reunion process of the tendon ends were seen between the immobilized and nonimmobilized groups. Moreover, inflammatory cells were similar in both groups and reflected a transient tissue reaction to the membrane. Within the follow-up, the seam area (cross-sectional) approached that of intact controls. (c) 2007 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  16. Reconstruction of the esophagojejunostomy by double stapling method using EEA™ OrVil™ in laparoscopic total gastrectomy and proximal gastrectomy

    OpenAIRE

    Hirahara, Noriyuki; Monma, Hiroyuki; Shimojo, Yoshihide; Matsubara, Takeshi; Hyakudomi, Ryoji; Yano, Seiji; Tanaka, Tsuneo

    2011-01-01

    Abstract Here we report the method of anastomosis based on double stapling technique (hereinafter, DST) using a trans-oral anvil delivery system (EEATM OrVilTM) for reconstructing the esophagus and lifted jejunum following laparoscopic total gastrectomy or proximal gastric resection. As a basic technique, laparoscopic total gastrectomy employed Roux-en-Y reconstruction, laparoscopic proximal gastrectomy employed double tract reconstruction, and end-to-side anastomosis was used for the cut-off...

  17. THE ANALYSIS OF CORRELATIONS BETWEEN THE MAIN TRAITS OF WOOL PRODUCTION ON PALAS SHEEP LINE FOR MEAT, MILK AND HIGH PROLIFICACY

    Directory of Open Access Journals (Sweden)

    ANA ENCIU

    2008-10-01

    Full Text Available The aim of this paper was to analyze the coefficient of phenotypic correlation and regression between main wool production traits for the sheep belonging to the Palas line specialized for meat, milk and with high prolificacy. The study was performed on a 10 years interval, the phenotypic correlation and the regression being determined for age groups and body weight classes for the following traits: raw wool production, the staple length, wool diameter and body weight at shearing. The obtained results are showing that for the specialized sheep lines the efficiency of wool production is also higher for the sheep with moderate body weights but for these sheep lines the selection for body weight will be done based on the morphoproductive parameters specific to the purpose of exploitation (milk production, meat production or high prolificacy.

  18. Assessment of MRI issues at 3-Tesla for metallic surgical implants: findings applied to 61 additional skin closure staples and vessel ligation clips.

    Science.gov (United States)

    Gill, Amreeta; Shellock, Frank G

    2012-01-09

    Metallic skin closure staples and vessel ligation clips should be tested at 3-Tesla to characterize MRI issues in order to ensure patient safety. Therefore, metallic surgical implants were assessed at 3-Tesla for magnetic field interactions, MRI-related heating, and artifacts. A skin closure staple (Visistat Skin Stapler, staple, Polytetrafluoroethylene, PTFE, coated 316L/316LVM stainless steel; Teleflex Medical, Durham, NC) and a vessel ligation clip (Hemoclip Traditional, stainless steel; Teleflex Medical, Durham, NC) that represented the largest metallic sizes made from materials with the highest magnetic susceptibilities (i.e., based on material information) among 61 other surgical implants (52 metallic implants, 9 nonmetallic implants) underwent evaluation for magnetic field interactions, MRI-related heating, and artifacts using standardized techniques. MRI-related heating was assessed by placing each implant in a gelled-saline-filled phantom with MRI performed using a transmit/receive RF body coil at an MR system reported, whole body averaged SAR of 2.9-W/kg for 15-min. Artifacts were characterized using T1-weighted, SE and GRE pulse sequences. Each surgical implant showed minor magnetic field interactions (20- and 27-degrees, which is acceptable from a safety consideration). Heating was not substantial (highest temperature change, ≤ 1.6°C). Artifacts may create issues if the area of interest is in the same area or close to the respective surgical implant. The results demonstrated that it would be acceptable for patients with these metallic surgical implants to undergo MRI at 3-Tesla or less. Because of the materials and dimensions of the surgical implants that underwent testing, these findings pertain to 61 additional similar implants.

  19. Assessment of MRI issues at 3-Tesla for metallic surgical implants: findings applied to 61 additional skin closure staples and vessel ligation clips

    Directory of Open Access Journals (Sweden)

    Gill Amreeta

    2012-01-01

    Full Text Available Abstract Purpose Metallic skin closure staples and vessel ligation clips should be tested at 3-Tesla to characterize MRI issues in order to ensure patient safety. Therefore, metallic surgical implants were assessed at 3-Tesla for magnetic field interactions, MRI-related heating, and artifacts. Methods A skin closure staple (Visistat Skin Stapler, staple, Polytetrafluoroethylene, PTFE, coated 316L/316LVM stainless steel; Teleflex Medical, Durham, NC and a vessel ligation clip (Hemoclip Traditional, stainless steel; Teleflex Medical, Durham, NC that represented the largest metallic sizes made from materials with the highest magnetic susceptibilities (i.e., based on material information among 61 other surgical implants (52 metallic implants, 9 nonmetallic implants underwent evaluation for magnetic field interactions, MRI-related heating, and artifacts using standardized techniques. MRI-related heating was assessed by placing each implant in a gelled-saline-filled phantom with MRI performed using a transmit/receive RF body coil at an MR system reported, whole body averaged SAR of 2.9-W/kg for 15-min. Artifacts were characterized using T1-weighted, SE and GRE pulse sequences. Results Each surgical implant showed minor magnetic field interactions (20- and 27-degrees, which is acceptable from a safety consideration. Heating was not substantial (highest temperature change, ≤ 1.6°C. Artifacts may create issues if the area of interest is in the same area or close to the respective surgical implant. Conclusions The results demonstrated that it would be acceptable for patients with these metallic surgical implants to undergo MRI at 3-Tesla or less. Because of the materials and dimensions of the surgical implants that underwent testing, these findings pertain to 61 additional similar implants.

  20. Assessment of MRI issues at 3-Tesla for metallic surgical implants: findings applied to 61 additional skin closure staples and vessel ligation clips

    Science.gov (United States)

    2012-01-01

    Purpose Metallic skin closure staples and vessel ligation clips should be tested at 3-Tesla to characterize MRI issues in order to ensure patient safety. Therefore, metallic surgical implants were assessed at 3-Tesla for magnetic field interactions, MRI-related heating, and artifacts. Methods A skin closure staple (Visistat Skin Stapler, staple, Polytetrafluoroethylene, PTFE, coated 316L/316LVM stainless steel; Teleflex Medical, Durham, NC) and a vessel ligation clip (Hemoclip Traditional, stainless steel; Teleflex Medical, Durham, NC) that represented the largest metallic sizes made from materials with the highest magnetic susceptibilities (i.e., based on material information) among 61 other surgical implants (52 metallic implants, 9 nonmetallic implants) underwent evaluation for magnetic field interactions, MRI-related heating, and artifacts using standardized techniques. MRI-related heating was assessed by placing each implant in a gelled-saline-filled phantom with MRI performed using a transmit/receive RF body coil at an MR system reported, whole body averaged SAR of 2.9-W/kg for 15-min. Artifacts were characterized using T1-weighted, SE and GRE pulse sequences. Results Each surgical implant showed minor magnetic field interactions (20- and 27-degrees, which is acceptable from a safety consideration). Heating was not substantial (highest temperature change, ≤ 1.6°C). Artifacts may create issues if the area of interest is in the same area or close to the respective surgical implant. Conclusions The results demonstrated that it would be acceptable for patients with these metallic surgical implants to undergo MRI at 3-Tesla or less. Because of the materials and dimensions of the surgical implants that underwent testing, these findings pertain to 61 additional similar implants. PMID:22230200

  1. Local Staple Food Price Indices in the Age of Biofuels

    Science.gov (United States)

    Brown, Molly E.

    2012-01-01

    In many poor, food insecure regions, agriculture is a primary source of income and farmers are reliant both on their own production and on purchasing food in the market to feed their families. Large local food price increases over a short time period can be indicative of a deteriorating food security situation and may be the consequence of weather-related food production declines, Dr can simply be the result of price transmission from the international commodity market. Food price indices developed by the United Nations Food and Agriculture Organization (FAO) are used to monitor food price trends at a global level, but largely reflect supply and demand conditions in export markets far from the places where the chronically food insecure live. A much better understanding of how local staple food prices in isolated regions such as West Africa that grow most of the food they eat to better understand the impact of global commodity market transformations on sensitive communities at the margin. This information will also enable improved strategies for these farmers who are extraordinarily sensitive to climate change impacts on agricultural growing conditions.

  2. MRI study of bioabsorbable poly-L-lactic acid devices used for fixation of fracture and osteotomies

    International Nuclear Information System (INIS)

    Marumo, Keishi; Sato, Yasutomo; Suzuki, Hidehiko; Kurosaka, Daisaburo

    2006-01-01

    The overall clinical results of bioabsorbable fixation devices made of poly-L-lactic acid (PLLA) used for fixation of fractures, bone grafting, and osteotomies have been favorable. However, clinical studies demonstrated no sign of normal bony architecture restored after surgery, although implant channels had been filled with fibrous tissue. The purpose of the present retrospective study was to examine the extent of structural changes in PLLA devices (PLLA-Ds) for fixation of rotational acetabular osteotomies and displaced malleolar ankle fractures using magnetic resonance imaging (MRI). Altogether, 14 patients with osteoarthritis of hip joints and 15 with displaced malleolar ankle fractures were operated on using PLLA-D (NEOFIX). Of these patients, 22 were finally enrolled in the study, and the period from operation to the time of the study ranged from 17 to 78 months. The postoperative radiographic findings were evaluated for union, and changes around the implant holes were classified as sclerosis, resorption, or no change. MRI was carried out to estimate changes in the PLLA-Ds. Bone union was obtained in all cases; clinical complications such as infection, joint effusion, soft tissue irritation due to PLLA-D deviation, and motion pain in the joints were not observed. The MRI study suggested that water content in PLLA-D increased mainly due to biodegradation and that implants were not replaced by bony tissue. The PLLA-Ds were degraded but were not replaced by bony tissue during the observation period. Considering these findings and the assumption that in bony tissues mechanical strength of PLLA-D decreases with time, attention should be paid to mechanical insufficiency, which may occur when the cross-sectional area of a PLLA-D extends beyond the cross-sectional area of the osteosynthesis site. (author)

  3. The Chemistry of Diet: Medicine, Nutrition, and Staple Foods in Imperial Brazil.

    Science.gov (United States)

    Loureiro de Mendonça Couto, Cristiana

    2015-01-01

    Brazilian cuisine is much admired by present-day international chefs. However, in the nineteenth century, local ingredients and recipes were looked down upon by the Portuguese colonists, as well as by visiting European naturalists. This fact, together with medical and chemical views formulated throughout the 1800s, led locally trained doctors to attribute the occurrence of countless diseases that devastated Rio de Janeiro to local staple foods, particularly corn and manioc flour. In the first part of the present article, I review the dietary habits of Brazilians through the eyes of European naturalists who travelled across the country in the early nineteenth century. In the second part, I summarise the ideas formulated by French and German chemists on the components, and consequent nutritional value, of cereals and other sources of flour, and then analyse the appropriation of such ideas--particularly those of Justus Liebig--by Brazilian doctors and their adaptation to local conditions.

  4. Greenhouse gas emissions and reactive nitrogen releases during the life-cycles of staple food production in China and their mitigation potential.

    Science.gov (United States)

    Xia, Longlong; Ti, Chaopu; Li, Bolun; Xia, Yongqiu; Yan, Xiaoyuan

    2016-06-15

    Life-cycle analysis of staple food (rice, flour and corn-based fodder) production and assessments of the associated greenhouse gas (GHG) and reactive nitrogen (Nr) releases, from environmental and economic perspectives, help to develop effective mitigation options. However, such evaluations have rarely been executed in China. We evaluated the GHG and Nr releases per kilogram of staple food production (carbon and Nr footprints) and per unit of net economic benefit (CO2-NEB and Nr-NEB), and explored their mitigation potential. Carbon footprints of food production in China were obviously higher than those in some developed countries. There was a high spatial variation in the footprints, primarily attributable to differences in synthetic N use (or CH4 emissions) per unit of food production. Provincial carbon footprints had a significant linear relationship with Nr footprints, attributed to large contribution of N fertilizer use to both GHG and Nr releases. Synthetic N fertilizer applications and CH4 emissions dominated the carbon footprints, while NH3 volatilization and N leaching were the main contributors to the Nr footprints. About 564 (95% uncertainty range: 404-701) TgCO2eqGHG and 10 (7.4-12.4) Tg Nr-N were released every year during 2001-2010 from staple food production. This caused the total damage costs of 325 (70-555) billion ¥, equivalent to nearly 1.44% of the Gross Domestic Product of China. Moreover, the combined damage costs and economic input costs, accounted for 66%-80% of the gross economic benefit generated from food production. A reduction of 92.7TgCO2eqyr(-1) and 2.2TgNr-Nyr(-1) could be achieved by reducing synthetic N inputs by 20%, increasing grain yields by 5% and implementing off-season application of straw and mid-season drainage practices for rice cultivation. In order to realize these scenarios, an ecological compensation scheme should be established to incentivize farmers to gradually adopt knowledge-based managements. Copyright © 2016

  5. Osteólise extensa após uso de âncora bioabsorvível: relato de caso e revisão da literatura Extensive osteolysis after the use of a bioabsorbable suture anchor: case report and literature review

    Directory of Open Access Journals (Sweden)

    Fabio Farina Dal Molin

    2010-01-01

    Full Text Available Os implantes bioabsorvíveis são usados com muita frequência no tratamento das lesões do manguito rotador e lesões labiais do ombro. Vários pesquisadores observaram áreas pequenas de osteólise depois da utilização destas âncoras bioabsorvíveis no tratamento das patologias do ombro. Teorias biológicas e mecânicas são levantadas para justificar a osteólise causada por estes materiais. É descrito o caso de um paciente que realizou, simultaneamente, sutura do manguito rotador com a técnica de dupla fileira e sutura da lesão de Bankart com âncoras bioabsorvíveis de PLDLA e fios Fiber Wire®; evoluindo com extensa osteólise do colo anatômico do úmero. Tendo em vista que foi utilizada uma âncora na glenoide e esta não apresentou osteólise, levanta-se a hipótese de que os fatores mecânicos sejam importantes na etiologia desta complicação.Bioabsorbable implants are frequently used in the treatment of rotator cuff and shoulder labrum injuries. Many authors have observed small areas of osteolysis after repair of shoulder abnormalities with absorbable anchors. Biological and mechanic theories are put forward to account for the osteolysis caused by these materials. We present a case of a patient who was simultaneously treated for a rotator cuff lesion with the double-row technique and a Bankart lesion with bioabsorbable PLLA anchors, and developed extensive osteolysis of the anatomic neck of the humerus. Because no lysis appeared in the glenoid around the other PLLA implant, we hypothesized that mechanical factors are important in the etiology of this complication.

  6. Sexuality and fertility outcomes after hand sewn versus stapled ileal pouch anal anastomosis for ulcerative colitis.

    Science.gov (United States)

    Harnoy, Yann; Desfourneaux, Véronique; Bouguen, Guillaume; Rayar, Michel; Meunier, Bernard; Siproudhis, Laurent; Boudjema, Karim; Sulpice, Laurent

    2016-01-01

    Ileal pouch anal anastomosis (IPAA) may alter sexuality and fertility in women. The laparoscopic approach seems to reduce infertility rates in women after IPAA. However, the impact of hand sewn versus stapled IPAA on sexuality and fertility has never been assessed in patients with ulcerative colitis (UC). The objective of this study was to analyze the impact of the IPAA technique on sexuality and fertility in UC. All UC patients who underwent an IPAA between May 1996 and April 2011 were included. The patients answered mailed questionnaires including sexuality validated questionnaires and fertility questionnaires. The risk factors of sexual dysfunction were explored. A total of 135 patients were included. Eighty-eight patients (65%) answered the questionnaires. Their mean age and follow-up were 37.2 ± 13.4 y and 109.7 ± 57.5 mo. The rates of female and male sexual dysfunction were 50% and 29%, respectively. Intestinal transit disorders were identified as risk factors in both men and women and anastomotic stricture in women sexual dysfunction, in univariate analyses. The IPAA technique did not impact sexual function in women but there was a trend for less erectile dysfunction after hand sewn IPAA (16.7% versus 44.4%). The fertility rate was 47% in women and 75% in men, with a trend for a better fertility in women after hand sewn IPAA (P = 0.07). In this preliminary study, the hand sewn or stapled IPAA technique did not impact the sexuality or fertility outcomes of UC patients, but there was a trend for better female fertility and male erectile function after hand sewn IPAA. Intestinal transit disorders contributed to male and female sexual dysfunction after IPAA. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. A new anastomotic leakage model in circular double stapled colorectal anastomosis after low anterior rectum resection in pigs.

    Science.gov (United States)

    Wenger, F A; Szucsik, E; Hoinoiu, B F; Ionac, M; Walz, M K; Schmid, K W; Reis, H

    2013-12-01

    A high incidence of anastomotic leakage (37.5%) is reported after low anterior rectal resection (LAR) and circular double-stapled anastomosis without protective ileostoma. Since the pathomechanism of anastomosis leakage is still unclear, a suitable animal model would be most desirable. The objective was to assess the incidence of clinically apparent and inapparent leakage after LAR in pigs (n = 20). Endpoints were radiological, clinical, macroscopic, and histologic proof of anastomotic leakage on the 9th postoperative day. Integrity of anastomosis was assessed by double-contrast barium examination on 9th postoperative day. Animals were sacrificed and anastomoses were resected for histopathological investigation. In case of earlier clinical apparent anastomotic leakage, radiologic double-contrast barium was performed immediately. LAR with a circular double-stapled anastomosis without protective ileostoma was performed in 20 pigs (m:f = 8:12). Length of resection was 10-20 cm, anastomosis was performed 7 cm ab ano. Five animals (25%) developed clinical apparent anastomotic leakage (no appetite, fever, inactivity, tachypnea, discomfort, pain) between the 6th (n = 1) and 9th (n = 4) postoperative day, proven by double-contrast barium radiographs. Additionally in 1 animal clinical inapparent anastomotic insufficiency was observed radiologically. Total rate of leakage was 30% (n = 6). These results were confirmed by leucocytosis, low potassium levels, in two cases high ALT and AST and local peritonitis in all cases. Including one additional case of clinical inapparent leakage, total rate of anastomotic leakage was 30% (6/20). Thus we managed to establish a new experimental model of anastomotic leakage after low rectal resection comparable to the human situation.

  8. Lybatides from Lycium barbarum Contain An Unusual Cystine-stapled Helical Peptide Scaffold.

    Science.gov (United States)

    Tan, Wei Liang; Wong, Ka H; Lei, Jian; Sakai, Naoki; Tan, Hong Wei; Hilgenfeld, Rolf; Tam, James P

    2017-07-12

    Cysteine-rich peptides (CRPs) of 2-6 kDa are generally thermally and proteolytically stable because of their multiple cross-bracing disulfide bonds. Here, we report the discovery and characterization of two novel cystine-stapled CRPs, designated lybatide 1 and 2 (lyba1 and lyba2), from the cortex of Lycium barbarum root. Lybatides, 32 to 33 amino acids in length, are hyperstable and display a novel disulfide connectivity with a cysteine motif of C-C-C-C-CC-CC which contains two pairs of adjacent cysteines (-CC-CC). X-ray structure analysis revealed the presence of a single cystine-stabilized (α + π)-helix in lyba2, a rare feature of CRPs. Together, our results suggest that lybatides, one of the smallest four-disulfide-constrained plant CRPs, is a new family of CRPs. Additionally, this study provides new insights into the molecular diversity of plant cysteine-rich peptides and the unusual lybatide scaffold could be developed as a useful template for peptide engineering and therapeutic development.

  9. Fortification of staple foods with zinc for improving zinc status and other health outcomes in the general population.

    Science.gov (United States)

    Shah, Dheeraj; Sachdev, Harshpal S; Gera, Tarun; De-Regil, Luz Maria; Peña-Rosas, Juan Pablo

    2016-06-09

    Zinc deficiency is a global nutritional problem, particularly in children and women residing in settings where diets are cereal based and monotonous. It has several negative health consequences. Fortification of staple foods with zinc may be an effective strategy for preventing zinc deficiency and improving zinc-related health outcomes. To evaluate the beneficial and adverse effects of fortification of staple foods with zinc on health-related outcomes and biomarkers of zinc status in the general population. We searched the following databases in April 2015: Cochrane Central Register of Controlled Trials (CENTRAL, Issue 3 of 12, 2015, the Cochrane Library), MEDLINE & MEDLINE In Process (OVID) (1950 to 8 April 2015), EMBASE (OVID) (1974 to 8 April 2015), CINAHL (1982 to April 2015), Web of Science (1900 to 9 April 2015), BIOSIS (1969 to 9 April 2015), POPLINE (1970 to April 2015), AGRICOLA, OpenGrey, BiblioMap, and Trials Register of Promoting Health Interventions (TRoPHI), besides regional databases (April 2015) and theses. We also searched clinical trial registries (17 March 2015) and contacted relevant organisations (May 2014) in order to identify ongoing and unpublished studies. We included randomised controlled trials, randomised either at the level of the individual or cluster. We also included non-randomised trials at the level of the individual if there was a concurrent comparison group. We included non-randomised cluster trials and controlled before-after studies only if there were at least two intervention sites and two control sites. Interventions included fortification (central/industrial) of staple foods (cereal flours, edible fats, sugar, condiments, seasonings, milk and beverages) with zinc for a minimum period of two weeks. Participants were members of the general population who were over two years of age (including pregnant and lactating women) from any country. Two review authors independently assessed the eligibility of studies for inclusion

  10. Early tension loss in an anterior cruciate ligament graft. A cadaver study of four tibial fixation devices.

    Science.gov (United States)

    Grover, Dustin M; Howell, Stephen M; Hull, Maury L

    2005-02-01

    The tensile force applied to an anterior cruciate ligament graft determines the maximal anterior translation; however, it is unknown whether the tensile force is transferred to the intra-articular portion of the graft and whether the intra-articular tension and maximal anterior translation are maintained shortly after ligament reconstruction. Ten cadaveric knees were reconstructed with a double-looped tendon graft. The graft was looped through a femoral fixation transducer that measured the resultant force on the proximal end of the graft. A pneumatic cylinder applied a tensile force of 110 N to the graft exiting the tibial tunnel with the knee in full extension. The graft was fixed sequentially with four tibial fixation devices (a spiked metal washer, double staples, a bioabsorbable interference screw, and a WasherLoc). Three cyclic loading treatments designed to conservatively load the graft and its fixation were applied. The combined loss in intra-articular graft tension from friction, insertion of the tibial fixation device, and three cyclic loading treatments was 50% for the spiked washer (p = 0.0004), 100% for the double staples (p < 0.0001), 64% for the interference screw (p = 0.0001), and 56% for the WasherLoc (p < 0.0001). The tension loss caused an increase in the maximal anterior translation from that of the intact knee of 2.0 mm for the spiked washer (p = 0.005), 7.8 mm for the double staples (p < 0.0001), 2.7 mm for the interference screw (p = 0.001), and 2.1 mm for the WasherLoc (p < 0.0001). The tensile force applied to a soft-tissue anterior cruciate ligament graft is not transferred intra-articularly and is not maintained during graft fixation. The loss in tension is caused by friction in the tibial tunnel and wrapping the graft around the shank of the screw of the spiked washer, insertion of the tibial fixation device, and cyclical loading of the knee. The amount of tension loss is sufficient to increase the maximal anterior translation.

  11. Nutritional Status of Water-soluble Vitamins Did not Differ According to Intake Levels of Wheat and Wheat Alternatives and Rice and Rice Alternatives as a Staple Food in Pregnant Japanese Women

    Directory of Open Access Journals (Sweden)

    Katsumi Shibata

    2013-01-01

    Full Text Available The objective of this study was to investigate whether the intake level of a staple food influences the nutritional status of water-soluble vitamins in pregnant Japanese women. Urinary excretion of water-soluble vitamins was used as a biomarker for nutritional assessment. Twenty-four-hour urine samples were collected and vitamin intake was surveyed using a validated self-administered comprehensive diet history questionnaire. Subjects were categorized into bottom, middle, and upper tertiles according to the percentage of total energy intake from wheat and wheat alternatives or rice and rice alternatives. The present study showed that the nutritional status of water-soluble vitamins did not differ with intake level of wheat and wheat alternatives or rice and rice alternatives as a staple food in pregnant Japanese women.

  12. Comparative evaluation of a bioabsorbable collagen membrane and connective tissue graft in the treatment of localized gingival recession: A clinical study

    Directory of Open Access Journals (Sweden)

    Harsha Mysore Babu

    2011-01-01

    Full Text Available Background: Gingival recession (GR can result in root sensitivity, esthetic concern to the patient, and predilection to root caries. The purpose of this randomized clinical study was to evaluate (1 the effect of guided tissue regeneration (GTR procedure using a bioabsorbable collagen membrane, in comparison to autogenous subepithelial connective tissue graft (SCTG for root coverage in localized gingival recession defects; and (2 the change in width of keratinized gingiva following these two procedures. Materials and Methods: A total of 10 cases, showing at least two localized Miller′s Class I or Class II gingival recession, participated in this study. In a split mouth design, the pairs of defects were randomly assigned for treatment with either SCTG (SCTG Group or GTR-based collagen membrane (GTRC Group. Both the grafts were covered with coronally advanced flap. Recession depth (RD, recession width (RW, width of keratinized gingiva (KG, probing depth (PD, relative attachment level (RAL, plaque index (PI, and gingival index (GI were recorded at baseline, 3 and 6 months postoperatively. Results: Six months following root coverage procedures, the mean root coverage was found to be 84.84% ± 16.81% and 84.0% ± 15.19% in SCTG Group and GTRC Group, respectively. The mean keratinized gingival width increase was 1.50 ± 0.70 mm and 2.30 ± 0.67 mm in the SCTG and GTRC group, respectively, which was not statistically significant. Conclusion: It may be concluded that resorbable collagen membrane can be a reliable alternative to autogenous connective tissue graft in the treatment of gingival recession.

  13. Capability of MRI for the indication at arthroscopic staple capsulorrhaphy on traumatic anterior instability of the shoulder

    International Nuclear Information System (INIS)

    Horii, Motoyuki; Kurokawa, Masao; Kubo, Toshikazu; Yamashita, Taku; Hirasawa, Yasusuke; Katsumi, Yasukazu.

    1996-01-01

    We compared MRI findings in the shoulder with arthroscopic findings of the anterior part of inferior gleno-humeral ligament (AIGHL) in 49 shoulders showing traumatic anterior instability (TAI). Arthroscopic findings were classified into two types according to whether the AIGHL is adequately wide and thick for arthroscopic staple capsulorrhaphy (ASC). MRI findings were graded into two types according to the continuity of the articular capsule in 23 shoulders examined by MR arthrograms and according to the morphology of the anterior labrum in 26 examined by conventional MRI. In each shoulder, two or three different sections containing the anteroinferior area of the glenoid were evaluated. MRI findings were significantly correlated with arthroscopic findings. Both MR arthrograms and conventional MRI are useful for determining the indications for ASC. (author)

  14. Results of More Than 11,800 Sleeve Gastrectomies: Data Analysis of the German Bariatric Surgery Registry.

    Science.gov (United States)

    Stroh, Christine; Köckerling, Ferdinand; Volker, Lange; Frank, Benedix; Stefanie, Wolff; Christian, Knoll; Christiane, Bruns; Thomas, Manger

    2016-05-01

    Laparoscopic sleeve gastrectomy (SG) is an upcoming procedure in bariatric surgery and is currently performed worldwide. Staple line leakage, as the most frequent and most feared complication, is still a major concern. Since 2005 data from patients undergoing bariatric procedures in Germany have been prospectively registered in an online database and analyzed. All patients who had undergone primary SG within a 7-year period were considered for analysis. Using the German Bariatric Surgery Registry, data from more than 11,800 SGs were collected between January 1, 2005, and December 31, 2013. Staple line leak rate decreased from 6.5% to 1.4%. Male sex, higher body mass index, concomitant sleep apnea, conversion to laparotomy, longer operation time, a combination of buttresses and oversewing, and the occurrence of intraoperative complications were associated with a significantly higher leakage rate compared with when using either buttresses or oversewing alone. On multivariable analysis, operation time and year of procedure only had a significant impact on staple line leakage rate. Owing to the growing experience a constant decrease in the leakage rate after SG has been observed. Staple line disruption may still lead to sepsis, multiorgan dysfunction, and increased mortality. The results of the current study demonstrated that there are factors that increase the risk of leakage and which would enable surgeons to define risk groups, select patients more carefully, and offer closer follow-up during the postoperative course with early recognition and adequate treatment.

  15. Mechanical properties of biaxially strained poly(L-lactide) tubes: Strain rate and temperature dependence

    DEFF Research Database (Denmark)

    Løvdal, Alexandra Liv Vest; Andreasen, Jens Wenzel; Mikkelsen, Lars Pilgaard

    2017-01-01

    Poly(l-lactide) (PLLA) is a bioabsorbable polymer with high stiffness and strength compared to the other commercially available bioabsorbable polymers. The properties of PLLA can be improved by straining, causing deformation-mediated molecular orientation. PLLA tubes were biaxially strained above...

  16. Early rectal stenosis following stapled rectal mucosectomy for hemorrhoids

    Directory of Open Access Journals (Sweden)

    Schuster Anja

    2004-05-01

    Full Text Available Abstract Background Within the last years, stapled rectal mucosectomy (SRM has become a widely accepted procedure for second and third degree hemorrhoids. One of the delayed complications is a stenosis of the lower rectum. In order to evaluate the specific problem of rectal stenosis following SRM we reviewed our data with special respect to potential predictive factors or stenotic events. Methods A retrospective analysis of 419 consecutive patients, which underwent SRM from December 1998 to August 2003 was performed. Only patients with at least one follow-up check were evaluated, thus the analysis includes 289 patients with a mean follow-up of 281 days (±18 days. For statistic analysis the groups with and without stenosis were evaluated using the Chi-Square Test, using the Kaplan-Meier statistic the actuarial incidence for rectal stenosis was plotted. Results Rectal stenosis was observed in 9 patients (3.1%, eight of these stenoses were detected within the first 100 days after surgery; the median time to stenosis was 95 days. Only one patient had a rectal stenosis after more than one year. 8 of the 9 patients had no obstructive symptoms, however the remaining patients complained of obstructive defecation and underwent surgery for transanal strictureplasty with electrocautery. A statistical analysis revealed that patients with stenosis had significantly more often prior treatment for hemorrhoids (p Conclusion Rectal stenosis is an uncommon event after SRM. Early stenosis will occur within the first three months after surgery. The majority of the stenoses are without clinical relevance. Only one of nine patients had to undergo surgery for a relevant stenosis. The predictive factor for stenosis in the patient-characteristics is previous interventions for hemorrhoids, severe postoperative pain might also predict rectal stenosis.

  17. Biodegradable Metals for Cardiovascular Stents: from Clinical Concerns to Recent Zn-Alloys.

    Science.gov (United States)

    Bowen, Patrick K; Shearier, Emily R; Zhao, Shan; Guillory, Roger J; Zhao, Feng; Goldman, Jeremy; Drelich, Jaroslaw W

    2016-05-01

    Metallic stents are used to promote revascularization and maintain patency of plaqued or damaged arteries following balloon angioplasty. To mitigate the long-term side effects associated with corrosion-resistant stents (i.e., chronic inflammation and late stage thrombosis), a new generation of so-called "bioabsorbable" stents is currently being developed. The bioabsorbable coronary stents will corrode and be absorbed by the artery after completing their task as vascular scaffolding. Research spanning the last two decades has focused on biodegradable polymeric, iron-based, and magnesium-based stent materials. The inherent mechanical and surface properties of metals make them more attractive stent material candidates than their polymeric counterparts. A third class of metallic bioabsorbable materials that are based on zinc has been introduced in the last few years. This new zinc-based class of materials demonstrates the potential for an absorbable metallic stent with the mechanical and biodegradation characteristics required for optimal stent performance. This review compares bioabsorbable materials and summarizes progress towards bioabsorbable stents. It emphasizes the current understanding of physiological and biological benefits of zinc and its biocompatibility. Finally, the review provides an outlook on challenges in designing zinc-based stents of optimal mechanical properties and biodegradation rate. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. A study of fuel failure behavior in high burnup HTGR fuel. Analysis by STRESS3 and STAPLE codes

    International Nuclear Information System (INIS)

    Martin, David G.; Sawa, Kazuhiro; Ueta, Shouhei; Sumita, Junya

    2001-05-01

    In current high temperature gas-cooled reactors (HTGRs), Tri-isotropic coated fuel particles are employed as fuel. In safety design of the HTGR fuels, it is important to retain fission products within particles so that their release to primary coolant does not exceed an acceptable level. From this point of view, the basic design criteria for the fuel are to minimize the failure fraction of as-fabricated fuel coating layers and to prevent significant additional fuel failures during operation. This report attempts to model fuel behavior in irradiation tests using the U.K. codes STRESS3 and STAPLE. Test results in 91F-1A and HRB-22 capsules irradiation tests, which were carried out at the Japan Materials Testing Reactor of JAERI and at the High Flux Isotope Reactor of Oak Ridge National Laboratory, respectively, were employed in the calculation. The maximum burnup and fast neutron fluence were about 10%FIMA and 3 x 10 25 m -2 , respectively. The fuel for the irradiation tests was called high burnup fuel, whose target burnup and fast neutron fluence were higher than those of the first-loading fuel of the High Temperature Engineering Test Reactor. The calculation results demonstrated that if only mean fracture stress values of PyC and SiC are used in the calculation it is not possible to predict any particle failures, by which is meant when all three load bearing layers have failed. By contrast, when statistical variations in the fracture stresses and particle specifications are taken into account, as is done in the STAPLE code, failures can be predicted. In the HRB-22 irradiation test, it was concluded that the first two particles which had failed were defective in some way, but that the third and fourth failures can be accounted for by the pressure vessel model. In the 91F-1A irradiation test, the result showed that 1 or 2 particles had failed towards the end of irradiation in the upper capsule and no particles failed in the lower capsule. (author)

  19. First-in-human evaluation of a bioabsorbable polymer-coated sirolimus-eluting stent: imaging and clinical results of the DESSOLVE I Trial (DES with sirolimus and a bioabsorbable polymer for the treatment of patients with de novo lesion in the native coronary arteries).

    Science.gov (United States)

    Ormiston, John; Webster, Mark; Stewart, James; Vrolix, Mathias; Whitbourn, Robert; Donohoe, Dennis; Knape, Charlene; Lansky, Alexandra; Attizzani, Guilherme F; Fitzgerald, Peter; Kandzari, David E; Wijns, William

    2013-10-01

    This first-in-human multicenter study sought to examine prospectively the safety and efficacy of a new, cobalt chromium thin-strut, coronary absorbable polymer-coated, sirolimus-eluting stent. Bioabsorbable polymers on drug-eluting stents may lower the long-term risks of inflammation, delayed healing, and adverse events. We enrolled patients with symptomatic coronary artery disease with stable or unstable angina pectoris and >50% diameter stenosis, amenable to coverage with a ≤23-mm long stent in a vessel 2.5 to 3.5 mm in diameter. All patients received dual antiplatelet therapy after implantation. Patients, in groups of 10, underwent repeat angiography, intravascular ultrasound, and optical coherence tomography at 4, 6, or 8 months, and all patients were seen or contacted at 18 months of follow-up. The median (range) in-stent late lumen loss (LLL) was 0.03 mm (-0.22 to 0.21 mm), 0.10 mm (-0.03 to 1.2 mm), and 0.08 mm (-0.01 to 0.28 mm), at 4, 6, and 8 months, respectively. At 18 months, the median in-stent LLL was 0.08 mm (-0.30 to 0.46 mm). On optical coherence tomography, the proportion of uncovered stent struts decreased from a median of 7.3% (range 0.4% to 46.3%) at 4 months to 0% (range: 0% to 3.4%) at 18 months. The percentage of neointimal volume obstruction by intravascular ultrasound increased from a median of 5.3% to 9.1% between 4 and 6 months and remained nearly unchanged thereafter through 18 months of follow-up. The only recorded major adverse cardiac event was a myocardial infarction. At 18 months of follow-up, this absorbable polymer-coated, cobalt chromium sirolimus-eluting stent was associated with a low and stable in-stent LLL, complete strut coverage, and no stent thrombosis. (First-In-Human Trial of the MiStent Drug-Eluting Stent [DES] in Coronary Artery Disease [DESSOLVE-I]; NCT01247428). Copyright © 2013 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  20. Household Coverage of Fortified Staple Food Commodities in Rajasthan, India.

    Directory of Open Access Journals (Sweden)

    Grant J Aaron

    Full Text Available A spatially representative statewide survey was conducted in Rajasthan, India to assess household coverage of atta wheat flour, edible oil, and salt. An even distribution of primary sampling units were selected based on their proximity to centroids on a hexagonal grid laid over the survey area. A sample of n = 18 households from each of m = 252 primary sampling units PSUs was taken. Demographic data on all members of these households were collected, and a broader dataset was collected about a single caregiver and a child in the first 2 years of life. Data were collected on demographic and socioeconomic status; education; housing conditions; recent infant and child mortality; water, sanitation, and hygiene practices; food security; child health; infant and young child feeding practices; maternal dietary diversity; coverage of fortified staples; and maternal and child anthropometry. Data were collected from 4,627 households and the same number of caregiver/child pairs. Atta wheat flour was widely consumed across the state (83%; however, only about 7% of the atta wheat flour was classified as fortifiable, and only about 6% was actually fortified (mostly inadequately. For oil, almost 90% of edible oil consumed by households in the survey was classified as fortifiable, but only about 24% was fortified. For salt, coverage was high, with almost 85% of households using fortified salt and 66% of households using adequately fortified salt. Iodized salt coverage was also high; however, rural and poor population groups were less likely to be reached by the intervention. Voluntary fortification of atta wheat flour and edible oil lacked sufficient industry consolidation to cover significant portions of the population. It is crucial that appropriate delivery channels are utilized to effectively deliver essential micronutrients to at-risk population groups. Government distribution systems are likely the best means to accomplish this goal.

  1. Overcoming inter-subspecific hybrid sterility in rice by developing indica-compatible japonica lines.

    Science.gov (United States)

    Guo, Jie; Xu, Xiaomei; Li, Wentao; Zhu, Wenyin; Zhu, Haitao; Liu, Ziqiang; Luan, Xin; Dai, Ziju; Liu, Guifu; Zhang, Zemin; Zeng, Ruizhen; Tang, Guang; Fu, Xuelin; Wang, Shaokui; Zhang, Guiquan

    2016-06-01

    Rice (Oryza sativa L.) is an important staple crop. The exploitation of the great heterosis that exists in the inter-subspecific crosses between the indica and japonica rice has long been considered as a promising way to increase the yield potential. However, the male and female sterility frequently occurred in the inter-subspecific hybrids hampered the utilization of the heterosis. Here we report that the inter-subspecific hybrid sterility in rice is mainly affected by the genes at Sb, Sc, Sd and Se loci for F1 male sterility and the gene at S5 locus for F1 female sterility. The indica-compatible japonica lines (ICJLs) developed by pyramiding the indica allele (S-i) at Sb, Sc, Sd and Se loci and the neutral allele (S-n) at S5 locus in japonica genetic background through marker-assisted selection are compatible with indica rice in pollen fertility and in spikelet fertility. These results showed a great promise of overcoming the inter-subspecific hybrid sterility and exploiting the heterosis by developing ICJLs.

  2. Use of 5-mm Laparoscopic Stapler to Perform Open Small Bowel Anastomosis in a Neonatal Animal Model.

    Science.gov (United States)

    Glenn, Ian C; Bruns, Nicholas E; Ponsky, Todd A

    2016-10-01

    While adult bowel anastomoses are typically performed with staplers, neonatal small bowel anastomoses have traditionally been performed in a hand-sewn manner due to the large size of surgical staplers. The purpose of this study was to compare stapled anastomosis using a newly available, 5-mm laparoscopic stapler to a hand-sewn anastomosis in an open animal model. Twenty anastomoses were performed by two general surgery residents (10 stapled and 10 hand-sewn) in an adult New Zealand white rabbit. The small bowel was divided with a scalpel. Surgical technique was alternated between single-layer hand-sewn and stapled anastomoses. Each anastomosis was resected for ex vivo testing. Measurements collected were outer diameter of the bowel before division, time to perform the anastomosis, anastomosis inner diameter (ID), and leak test. IDs were measured by cutting the anastomosis in cross-section, taking a photograph, and measuring the diameter by computer software. In addition, the surgeons qualitatively evaluated the anastomoses for hemostasis and overall quality. Statistical significance was determined using the Student's t-test. There were statistically significant differences between stapled and hand-sewn anastomosis, respectively, for average operative time (4 minutes 2 seconds versus 16 minutes 6 seconds, P animal model, a 5-mm stapled anastomosis is an acceptable alternative to hand-sewn small bowel anastomosis. The stapler is faster and creates a larger diameter anastomosis, however, there was one leak when closing the enterotomy in the stapled group and overlapping staple lines should be avoided.

  3. Climate Variability and Yields of Major Staple Food Crops in Northern Ghana

    Science.gov (United States)

    Amikuzuno, J.

    2012-12-01

    Climate variability, the short-term fluctuations in average weather conditions, and agriculture affect each other. Climate variability affects the agroecological and growing conditions of crops and livestock, and is recently believed to be the greatest impediment to the realisation of the first Millennium Development Goal of reducing poverty and food insecurity in arid and semi-arid regions of developing countries. Conversely, agriculture is a major contributor to climate variability and change by emitting greenhouse gases and reducing the agroecology's potential for carbon sequestration. What however, is the empirical evidence of this inter-dependence of climate variability and agriculture in Sub-Sahara Africa? In this paper, we provide some insight into the long run relationship between inter-annual variations in temperature and rainfall, and annual yields of the most important staple food crops in Northern Ghana. Applying pooled panel data of rainfall, temperature and yields of the selected crops from 1976 to 2010 to cointegration and Granger causality models, there is cogent evidence of cointegration between seasonal, total rainfall and crop yields; and causality from rainfall to crop yields in the Sudano-Guinea Savannah and Guinea Savannah zones of Northern Ghana. This suggests that inter-annual yields of the crops have been influenced by the total mounts of rainfall in the planting season. Temperature variability over the study period is however stationary, and is suspected to have minimal effect if any on crop yields. Overall, the results confirm the appropriateness of our attempt in modelling long-term relationships between the climate and crop yield variables.

  4. Device-specificity of vascular healing following implantation of bioresorbable vascular scaffolds and bioabsorbable-polymer metallic drugeluting stents in human coronary arteries. The ESTROFA OCT BVS vs. BP-DES study.

    Science.gov (United States)

    de la Torre Hernandez, Jose Maria; Gonzalo, Nieves; Otaegui, Imanol; Rumoroso, Jose R; Gutiérrez, Hipólito; Alfonso, Fernando; Marti, Gerard; Serrador Frutos, Ana; Brugaletta, Salvatore; Gomez Menchero, Antonio; Garcia Camarero, Tamara; Biagioni, Corina; Escaned, Javier

    2018-06-12

    We sought to compare vascular healing with bioresorbable everolimus-eluting vascular scaffolds (BVS) and drug-eluting stents with bioabsorbable polymers (BP-DES) at 6 and 12 months implanted both in same patients. Multicenter and prospective study including patients with at least two comparable lesions to treat. In every patient both BVS and BP-DES (Synergy™, Orsiro™ or Biomatrix Flex™) were implanted by lesion randomization. Patients included were evaluated with optical coherence tomography at 6 or 12 months (2:1). Finally, 68 patients had examination at 6 months and 27 patients at 12 months. Uncovered struts rates at 6 months were 1.7±3.2% for BVS and 5.3±5.6% for BP-DES (p=0.0001) and at 12 months 0.48±0.72% and 4.8±5% respectively (p=0.001). Rates of strut malapposition were significantly lower with BVS. There was no significant intra-patient correlation BP-DES / BVS for endpoints. Evaginations were more frequent and larger with BVS. Discontinuities in BVS were observed in 19.4% at 6 months and 14.3% at 12 months. Vascular healing with BVS and BP-DES could be more device-specific than patient-specific. At follow-up, BVS presented less uncovered or non-apposed struts than BP-DES but more frequent and larger evaginations. Discontinuities in BVS were relatively frequent at both time points.

  5. Hand-suture versus stapling for closure of loop ileostomy: HASTA-Trial: a study rationale and design for a randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Krüger Matthias

    2011-02-01

    Full Text Available Abstract Background Colorectal cancer is the second most common tumor in developed countries, with a lifetime prevalence of 5%. About one third of these tumors are located in the rectum. Surgery in terms of low anterior resection with mesorectal excision is the central element in the treatment of rectal cancer being the only option for definite cure. Creating a protective diverting stoma prevents complications like anastomotic failure and meanwhile is the standard procedure. Bowel obstruction is one of the main and the clinically and economically most relevant complication following closure of loop ileostomy. The best surgical technique for closure of loop ileostomy has not been defined yet. Methods/Design A study protocol was developed on the basis of the only randomized controlled mono-center trial to solve clinical equipoise concerning the optimal surgical technique for closure of loop ileostomy after low anterior resection due to rectal cancer. The HASTA trial is a multi-center pragmatic randomized controlled surgical trial with two parallel groups to compare hand-suture versus stapling for closure of loop ileostomy. It will include 334 randomized patients undergoing closure of loop ileostomy after low anterior resection with protective ileostomy due to rectal cancer in approximately 20 centers consisting of German hospitals of all level of health care. The primary endpoint is the rate of bowel obstruction within 30 days after ileostomy closure. In addition, a set of surgical and general variables including quality of life will be analyzed with a follow-up of 12 months. An investigators meeting with a practical session will help to minimize performance bias and enforce protocol adherence. Centers are monitored centrally as well as on-site before and during recruitment phase to assure inclusion, treatment and follow up according to the protocol. Discussion Aim of the HASTA trial is to evaluate the efficacy of hand-suture versus stapling for

  6. The Effects of Bougie Diameters on Tissue Oxygen Levels After Sleeve Gastrectomy: A Randomized Experimental Trial

    Directory of Open Access Journals (Sweden)

    Can Konca

    2018-05-01

    Full Text Available Background: Staple-line leak is the most frightening complication of laparoscopic sleeve gastrectomy and several predisposing factors such as using improper staple sizes regardless of gastric wall thickness, narrower bougie diameter and ischemia of the staple line are asserted. Aims: To evaluate the effects of different bougie diameters on tissue oxygen partial pressure at the esophagogastric junction after sleeve gastrectomy. Study Design: A randomized and controlled animal experiment with 1:1:1:1 allocation ratio. Methods: Thirty-two male Wistar Albino rats were randomly divided into 4 groups of 8 each. While 12-Fr bougies were used in groups 1 and 3, 8-Fr bougies were used in groups 2 and 4. Fibrin sealant application was also carried out around the gastrectomy line after sleeve gastrectomy in groups 3 and 4. Burst pressure of gastrectomy line, tissue oxygen partial pressure and hydroxyproline levels at the esophagogastric junction were measured and compared among groups. Results: Mortality was detected in 2 out of 32 rats (6.25% and one of them was in group 2 and the cause of this mortality was gastric leak. Gastric leak was detected in 2 out of 32 rats (6.25%. There was no significant difference in terms of burst pressures, tissue oxygen partial pressure and tissue hydroxyproline levels among the 4 groups. Conclusion: The use of narrower bougie along with fibrin sealant has not had a negative effect on tissue perfusion and wound healing.

  7. Parameter Data on the Radiocesium Transfer to Korean Staple Food Crops Following a Nuclear Accident

    International Nuclear Information System (INIS)

    Choi, Yong-Ho; Lim, Kwang-Muk; Jun, In; Kim, Byung-Ho; Keum, Dong-Kwon

    2016-01-01

    In order to decide an optimum countermeasure against farmland contaminations following a severe NPP accident, it is necessary to have a reliable tool for predicting the concentrations of radiocesium in crop plants. For the estimation of radionuclide concentrations in crop plants, various transfer parameters, which quantify the radionuclide transfer from one compartment to the next, are used in general. Some amount of transfer parameter data has been produced at the Korea Atomic Energy Research Institute (KAERI) over the last 30 years. The present work was conducted to collate the KAERI data on radiocesium in staple food crops and to suggest effective ways of using them for assessing the environmental impact of a nuclear accident. The transfer parameter values of radiocesium for rice, Chinese cabbage and radish varied considerably with soils and times of its deposition. The proposed representative values were mostly based on a limited amount of data so they cannot be considered to have a high representativeness. Accordingly, they are intended for provisional use and a continuous improvement should be made. It is necessary to produce a sufficient amount of additional domestic data on the indirect pathway by conducting root-uptake experiments with as many types of soil as possible

  8. Parameter Data on the Radiocesium Transfer to Korean Staple Food Crops Following a Nuclear Accident

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Yong-Ho; Lim, Kwang-Muk; Jun, In; Kim, Byung-Ho; Keum, Dong-Kwon [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    In order to decide an optimum countermeasure against farmland contaminations following a severe NPP accident, it is necessary to have a reliable tool for predicting the concentrations of radiocesium in crop plants. For the estimation of radionuclide concentrations in crop plants, various transfer parameters, which quantify the radionuclide transfer from one compartment to the next, are used in general. Some amount of transfer parameter data has been produced at the Korea Atomic Energy Research Institute (KAERI) over the last 30 years. The present work was conducted to collate the KAERI data on radiocesium in staple food crops and to suggest effective ways of using them for assessing the environmental impact of a nuclear accident. The transfer parameter values of radiocesium for rice, Chinese cabbage and radish varied considerably with soils and times of its deposition. The proposed representative values were mostly based on a limited amount of data so they cannot be considered to have a high representativeness. Accordingly, they are intended for provisional use and a continuous improvement should be made. It is necessary to produce a sufficient amount of additional domestic data on the indirect pathway by conducting root-uptake experiments with as many types of soil as possible.

  9. Evaluation of potential substrates for restenosis and thrombosis in overlapped versus edge-to-edge juxtaposed bioabsorbable scaffolds: Insights from a computed fluid dynamic study.

    Science.gov (United States)

    Rigatelli, Gianluca; Zuin, Marco; Dell'Avvocata, Fabio; Cardaioli, Paolo; Vassiliev, Dobrin; Ferenc, Miroslaw; Nghia, Nguyen Tuan; Nguyen, Thach; Foin, Nicholas

    2018-04-01

    Multiple BRSs and specifically the Absorb scaffold (BVS) (Abbott Vascular, Santa Clara, CA USA) have been often used to treat long diffuse coronary artery lesions. We evaluate by a computational fluid dynamic(CFD) study the impact on the intravascular fluid rheology on multiple bioabsorbable scaffolds (BRS) by standard overlapping versus edge-to-edge technique. We simulated the treatment of a real long significant coronary lesion (>70% luminal narrowing) involving the left anterior descending artery (LAD) treated with a standard or edge-to-edge technique, respectively. Simulations were performed after BVS implantations in two different conditions: 1) Edge-to-edge technique, where the scaffolds are kissed but not overlapped resulting in a luminal encroachment of 0.015cm (150μm); 2) Standard overlapping, where the scaffolds are overlapped resulting in a luminal encroachment of 0.030cm (300μm). After positioning the BVS across the long lesion, the implantation procedure was performed in-silico following all the usual procedural steps. Analysis of the wall shear stress (WSS) suggested that at the vessel wall level the WSS were lower in the overlapping zones overlapping compared to the edge-to-edge zone (∆=0.061Pa, p=0.01). At the struts level the difference between the two WSS was more striking (∆=1.065e-004 p=0.01) favouring the edge-to-edge zone. Our study suggested that at both vessel wall and scaffold struts levels, there was lowering WSS when multiple BVS were implanted with the standard overlapping technique compared to the "edge-to-edge" technique. This lower WSS might represent a substrate for restenosis, early and late BVS thrombosis, potentially explaining at least in part the recent evidences of devices poor performance. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Preoperative, intraoperative and postoperative risk factors for anastomotic leakage after laparoscopic low anterior resection with double stapling technique anastomosis.

    Science.gov (United States)

    Kawada, Kenji; Sakai, Yoshiharu

    2016-07-07

    Anastomotic leakage (AL) is one of the most devastating complications after rectal cancer surgery. The double stapling technique has greatly facilitated intestinal reconstruction especially for anastomosis after low anterior resection (LAR). Risk factor analyses for AL after open LAR have been widely reported. However, a few studies have analyzed the risk factors for AL after laparoscopic LAR. Laparoscopic rectal surgery provides an excellent operative field in a narrow pelvic space, and enables total mesorectal excision surgery and preservation of the autonomic nervous system with greater precision. However, rectal transection using a laparoscopic linear stapler is relatively difficult compared with open surgery because of the width and limited performance of the linear stapler. Moreover, laparoscopic LAR exhibits a different postoperative course compared with open LAR, which suggests that the risk factors for AL after laparoscopic LAR may also differ from those after open LAR. In this review, we will discuss the risk factors for AL after laparoscopic LAR.

  11. Outcome of everolimus eluting bioabsorbable vascular scaffold (BVS) compared to non BVS drug eluting stent in the management of ST-segment elevation myocardial infarction (STEMI) — A comparative study

    International Nuclear Information System (INIS)

    Chakraborty, Rabin; Patra, Soumya; Banerjee, Suvro; Pande, Arindam; Khan, Aftab; Mandol, Prakash Chandra; Ghosh, Debashish; De, Swapan Kumar; Das, Sankha Subhro; Nag, Raja

    2016-01-01

    Background: The safety and efficacy of everolimus eluting bioabsorbable vascular scaffold (BVS) in the management of “ST” segment elevation myocardial infarction (STEMI) are yet to be established. Aims: To evaluate immediate and short term safety and efficacy of the everolimus-eluting ABSORB BVS compared with non BVS drug eluting stent (DES) in patients with STEMI. Methods: From December 2013 to December 2014, 220 patients with STEMI were included in this study. Among them, 35 patients treated with BVS were compared with a control group composed of 180 patients who underwent non BVS DES implantation in the same time period. The incidence of major adverse cardiac events (MACE: stent thrombosis: death, non-fatal myocardial infarction, or target vessel/lesion revascularization) before discharge and up to six months was evaluated. Results: 1 vessel disease was more frequent whereas, 2 and 3 vessel disease was less frequent in BVS group. Procedural characteristics were also similar between groups, except for the use of post dilation (p = 0.04). Procedural success, in-hospital, and up to six-month MACE rates were similar between both groups. Definite or probable stent thrombosis did not occur (according to the ARC criteria) in BVS patients, though two patients during the index admission and another two patients in the first month after DES implantation had stent thrombosis. Conclusion: The use of the ABSORB BVS for STEMI is feasible and associated with good procedural safety, and angiographic success rate.

  12. Outcome of everolimus eluting bioabsorbable vascular scaffold (BVS) compared to non BVS drug eluting stent in the management of ST-segment elevation myocardial infarction (STEMI) — A comparative study

    Energy Technology Data Exchange (ETDEWEB)

    Chakraborty, Rabin; Patra, Soumya, E-mail: dr_soumyapatra@rediffmail.com; Banerjee, Suvro; Pande, Arindam; Khan, Aftab; Mandol, Prakash Chandra; Ghosh, Debashish; De, Swapan Kumar; Das, Sankha Subhro; Nag, Raja

    2016-04-15

    Background: The safety and efficacy of everolimus eluting bioabsorbable vascular scaffold (BVS) in the management of “ST” segment elevation myocardial infarction (STEMI) are yet to be established. Aims: To evaluate immediate and short term safety and efficacy of the everolimus-eluting ABSORB BVS compared with non BVS drug eluting stent (DES) in patients with STEMI. Methods: From December 2013 to December 2014, 220 patients with STEMI were included in this study. Among them, 35 patients treated with BVS were compared with a control group composed of 180 patients who underwent non BVS DES implantation in the same time period. The incidence of major adverse cardiac events (MACE: stent thrombosis: death, non-fatal myocardial infarction, or target vessel/lesion revascularization) before discharge and up to six months was evaluated. Results: 1 vessel disease was more frequent whereas, 2 and 3 vessel disease was less frequent in BVS group. Procedural characteristics were also similar between groups, except for the use of post dilation (p = 0.04). Procedural success, in-hospital, and up to six-month MACE rates were similar between both groups. Definite or probable stent thrombosis did not occur (according to the ARC criteria) in BVS patients, though two patients during the index admission and another two patients in the first month after DES implantation had stent thrombosis. Conclusion: The use of the ABSORB BVS for STEMI is feasible and associated with good procedural safety, and angiographic success rate.

  13. Ovarian cryopreservation after laparoscopic ovariectomy using the Endo-GIA stapling device and LAPRO-clip absorbable ligating clip in a woman: a case report

    Directory of Open Access Journals (Sweden)

    Messner Alexandra

    2011-02-01

    Full Text Available Abstract Introduction Several options are available for preserving fertility before cytotoxic treatment, including ovarian tissue cryopreservation. Most reported surgical techniques include electrocoagulation. Our hypothesis is that avoidance of electrocoagulation may decrease ovarian cortex injury during cryopreservation procedures. Case presentation We report a laparoscopic technique of whole-ovary removal without coagulation using Endo-GIA forceps and clips. Laparoscopic ovariectomy was performed for cryopreservation in a 37-year-old Caucasian woman with breast cancer and for whom chemotherapy was planned. The procedure was completed quickly and without complication. This Endo-GIA procedure was of short duration with a short period of ischemia before freezing. Conclusion Laparoscopic ovariectomy using the Endo-GIA stapling device procedure without coagulation may diminish ovary injury before ovarian cryopreservation.

  14. Ovarian cryopreservation after laparoscopic ovariectomy using the Endo-GIA stapling device and LAPRO-clip absorbable ligating clip in a woman: a case report

    Science.gov (United States)

    2011-01-01

    Introduction Several options are available for preserving fertility before cytotoxic treatment, including ovarian tissue cryopreservation. Most reported surgical techniques include electrocoagulation. Our hypothesis is that avoidance of electrocoagulation may decrease ovarian cortex injury during cryopreservation procedures. Case presentation We report a laparoscopic technique of whole-ovary removal without coagulation using Endo-GIA forceps and clips. Laparoscopic ovariectomy was performed for cryopreservation in a 37-year-old Caucasian woman with breast cancer and for whom chemotherapy was planned. The procedure was completed quickly and without complication. This Endo-GIA procedure was of short duration with a short period of ischemia before freezing. Conclusion Laparoscopic ovariectomy using the Endo-GIA stapling device procedure without coagulation may diminish ovary injury before ovarian cryopreservation. PMID:21291518

  15. Comparative morphology, biology and histology of reproductive development in three lines of Manihot esculenta Crantz (Euphorbiaceae: Crotonoideae).

    Science.gov (United States)

    Perera, P I P; Quintero, M; Dedicova, B; Kularatne, J D J S; Ceballos, H

    2013-01-01

    Cassava (Manihot esculenta), a major food staple in the tropics and subtropics, thrives even in environments undergoing threatening climate change. To satisfy the increasing demand for crop improvement and overcome the limitations of conventional breeding, the introduction of inbreeding techniques such as the production of doubled haploid lines via androgenesis or gynogenesis offers advantages. However, comprehensive studies on cassava flower bud biology or structural development are lacking and precise structural and biological information is a prerequisite to enhance the efficiency of these techniques. The floral biology of three selected cassava lines was studied, focusing on morphology, phenology and pollen biology (quantity, viability and dimorphism). Histological studies were also conducted on microsporogenesis/microgametogenesis and megasporogenesis/megagameto-genesis to generate precise developmental data for these lines. Male and female cyathia have distinct developmental phases. Pollen viability was high during immature stages of plant development; however, pollen mortality was common at later stages. Pollen trimorphism in male gametophytes towards the larger or smaller pollen size, as compared with normal size, was observed. Ten characteristic events were identified in male gametogenesis and six in female gametogenesis that were correlated with flower bud diameter. Male gametophyte diameter at different developmental stages was also determined. Results indicate that the three lines did not differ significantly, except regarding a few morphological aspects such as plant height, flower colour and number of male cyathia. Pollen grains were initially viable, but viability decreased drastically at later stages of growth. Abnormal meiosis or mitosis triggered pollen trimorphism. The demonstrated sequential events of reproductive development generated valuable information at the cellular level, which will help close the current information gap for cassava

  16. Utility of barium studies for patients with recurrent weight gain after Roux-en-Y gastric bypass

    International Nuclear Information System (INIS)

    Wang, B.; Levine, M.S.; Rubesin, S.E.; Williams, N.N.; Dumon, K.; Raper, S.

    2015-01-01

    Aim: To determine the utility of barium studies for detecting abnormalities responsible for recurrent weight gain after gastric bypass surgery. Methods: A computerized search identified 42 patients who had undergone barium studies for recurrent weight gain after gastric bypass and 42 controls. The images were reviewed to determine the frequency of staple-line breakdown and measure the length/width of the pouch and gastrojejunal anastomosis. A large pouch exceeded 6 cm in length or 5 cm in width and a wide anastomosis exceeded 2 cm. Records were reviewed for the amount of recurrent weight gain and subsequent weight loss after additional treatment. Results: Staple-line breakdown was present in 6/42 patients (14%) with recurrent weight gain. When measurements were obtained, 13/35 patients (37%) with recurrent weight gain had a large pouch, three (9%) had a wide anastomosis, and four (11%) had both, whereas 22/42 controls (52%) had a large pouch, one (2%) had a wide anastomosis, and two (5%) had both. Ten patients (24%) with recurrent weight gain underwent staple-line repair (n = 3) or pouch/anastomosis revision (n = 7). These 10 patients had a mean weight loss of 38.1 lbs versus a mean loss of 8.6 lbs in 19 patients managed medically. Conclusion: Only 14% of patients with recurrent weight gain after gastric bypass had staple-line breakdown, whereas 57% had a large pouch, wide anastomosis, or both. Not all patients with abnormal anatomy had recurrent weight gain, but those who did were more likely to benefit from surgical intervention than from medical management. - Highlights: • Only 14% of patients with recurrent weight gain after gastric bypass had GGFs. • The majority of patients with recurrent weight gain had a large pouch/wide GJA. • Many patients without recurrent weight gain also had a large pouch/wide GJA. • Those with weight gain and a large pouch/wide GJA are likely to benefit from surgery

  17. Laparoscopic correction of enterocele associated to stapled transanal rectal resection for obstructed defecation syndrome.

    Science.gov (United States)

    Carriero, Alfonso; Picchio, Marcello; Martellucci, Jacopo; Talento, Pasquale; Palimento, Domenico; Spaziani, Erasmo

    2010-03-01

    We report our experience of concomitant laparoscopic treatment for enterocele and stapled transanal rectal resection (STARR) for rectocele and/or rectal prolapse in patients with complex obstructed defecation syndrome (ODS). From June 2005 to June 2007, we submitted 20 patients with ODS due to rectal prolapse and/or rectocele, combined with stable enterocele, to STARR and laparoscopic correction of the enterocele. Preoperative assessment included symptom evaluation with standardized questionnaires, clinical examination, colonoscopy, proctoscopy, anal sphincter ultrasonography, video-defecography with synchronous opacification of the ileal loops in all patients and colpography in female patients, and anorectal manometry. Follow-up was performed in the first, third, sixth, 12th, and 24th month after surgery. Eighteen (90%) patients were submitted to both procedures, simultaneously. One patient, previously submitted to STARR, underwent laparoscopic treatment of the enterocele. Postoperative complications occurred in two (10%) patients: one case of postoperative rectal bleeding and one case of retropneumoperitoneum. Median (range) preoperative and postoperative Altomare's obstructed defecation score was ten (6-14) and two (0-14), respectively (p<0.001). Median (range) preoperative and postoperative quality of life score was 79 (39-109) and 109 (50-126), respectively (p<0.001). No symptom related to ODS was detected at 6-month follow-up (19 patients) and at 24-month follow-up (19 patients). The combination of STARR and laparoscopy provides a safe and effective method to treat ODS caused by rectal internal prolapse and/or rectocele combined with enterocele.

  18. Avaliação dos resultados da tenodese artroscópica do bíceps, utilizando-se parafuso de interferência bioabsorvível Evaluation of arthroscopic tenodesis of the biceps using a bioabsorbable interference screw

    Directory of Open Access Journals (Sweden)

    Sérgio Luiz Checchia

    2007-08-01

    Full Text Available OBJETIVO: Avaliar os resultados obtidos com a realização da tenodese da cabeça longa do bíceps (CLB pela técnica artroscópica, com a utilização de parafuso de interferência bioabsorvível biotenodese Arthrex®. MÉTODOS: Entre março de 2004 e abril de 2005, 16 ombros de 16 pacientes foram submetidos a tenodese da CLB com essa técnica. O seguimento mínimo foi de 12 meses, com média de 19,5 meses. A idade variou de 32 a 69 anos, com média de 56,1 anos. Houve predomínio do sexo masculino em 75% dos casos. O membro dominante foi acometido em 62,5% dos pacientes. Foi encontrada lesão parcial da CLB em 75% dos pacientes e instabilidade em 25%. Houve associação com lesão do manguito rotador (LMR em 93,75% dos casos. A avaliação clínica foi feita por meio dos critérios da University of California at Los Angeles (UCLA. RESULTADOS: Observamos excelentes resultados em todos os casos. Não foi observado em nenhum caso sinal de retração do músculo bíceps (sinal do Popeye, caracterizando soltura da tenodese. CONCLUSÃO: A tenodese da CLB pela técnica artroscópica, com a utilização de parafuso de interferência bioabsorvível biotenodese Arthrex® mostrou-se uma técnica eficiente para o tratamento das alterações da CLB.OBJECTIVE: To evaluate results obtained with arthroscopic tenodesis of the long head of the biceps (LHB using a bioabsorbable interference screw Arthrex® biotenodesis. METHODS: Between March 2004 and April 2005, 16 shoulders of 16 patients were submitted to LHB tenodesis using this technique. Minimum follow-up was 12 months, with a mean of 19.5 months. Age ranged from 32 to 69 years, mean of 56.1 years. Male patients prevailed, with 75% of the cases. The dominant limb was involved in 62.5% of the patients. Partial lesion of the LHB was found in 75% of the patients, and instability in 25%. Association to rotator cuff lesion (RCL was found in 93.75% of the cases. Clinical evaluation was based on the University of

  19. Development of an LC-MS/MS Determination Method for T-2 Toxin and Its Glucoside and Acetyl Derivatives for Estimating the Contamination of Total T-2 Toxins in Staple Flours.

    Science.gov (United States)

    Nakagawa, Hiroyuki; Matsuo, Yosuke; McCormick, Susan; Lim, Chee Wei

    2018-05-01

    A determination method previously validated for trichothecenes and zearalenone by means of liquid chromatography-tandem mass spectrometry (LC-MS/MS) was adapted for the quantification of T-2 toxin (T-2) as well as its glucoside and acetyl derivatives, T-2-3-glucoside (T-2-3G) and 3-acetyl-T-2 (3A-T-2). HT-2 toxin (HT-2) and its acetyl derivative 3-acetyl-HT-2 (3A-HT-2) were also included as the target chemicals. Staple flours (56 samples collected from the Singapore market) were examined for contamination from T-2 and/or HT-2 and their derivatives. Among them, 16 flours were found to be contaminated with T-2 and/or HT-2, whereas none was contaminated with T-2-3G and 3A-HT-2, except for trace 3A-T-2 detected in 2 rye samples. Rye flour samples were frequently contaminated with both T-2 and HT-2. Some of the reference materials (RMs) were further analyzed, and T-2-3G and 3A-T-2 were quantitatively detected in corn and wheat RMs. The ratio of T-2-3G to T-2 in the RMs seemed to be much lower than the ratio of deoxynivalenol-3-glucoside to deoxynivalenol usually reported in former studies. To the best of our knowledge, the natural contamination of 3A-T-2 in staple flour is reported here for the first time.

  20. Systematic review and meta-analysis of published, randomized, controlled trials comparing suture anastomosis to stapled anastomosis for ileostomy closure.

    Science.gov (United States)

    Sajid, M S; Craciunas, L; Baig, M K; Sains, P

    2013-12-01

    The objective of this article is to systematically analyze the randomized, controlled trials comparing the effectiveness of suture anastomosis (SUA) versus stapled anastomosis (STA) in patients undergoing ileostomy closure. Randomized, controlled trials comparing the effectiveness of SUA versus STA in patients undergoing ileostomy closure were analyzed using RevMan(®), and combined outcomes were expressed as odds risk ratio (OR) and standardized mean difference (SMD). Four randomized, controlled trials that recruited 645 patients were retrieved from electronic databases. There were 327 patients in the STA group and 318 patients in the SUA group. There was significant heterogeneity among included trials. Operative time (SMD -1.02; 95 % CI -1.89, -0.15; z = 2.29; p infection, reoperation and readmission were similar following STA and SUA in patients undergoing ileostomy closure. Length of hospital stay was also similar between STA and SUA groups. In ileostomy closure, STA was associated with shorter operative time and lower risk of postoperative small bowel obstruction. However, STA and SUA were similar in terms of anastomotic leak, surgical site infection, readmission, reoperations and length of hospital stay.

  1. Colovaginal anastomosis: an unusual complication of stapler use in restorative procedure after Hartmann operation

    Directory of Open Access Journals (Sweden)

    Liao Guoqing

    2005-11-01

    Full Text Available Abstract Background Rectovaginal fistula is uncommon after lower anterior resection for rectal cancer. The most leading cause of this complication is involvement of the posterior wall of the vagina into the staple line when firing the circular stapler. Case presentation A 50-year-old women underwent resection for obstructed carcinoma of the sigmoid colon with Hartmann procedure. Four months later she underwent restorative surgery with circular stapler. Following which she developed rectovaginal fistula. A transvaginal repair was performed but stool passing from vagina not per rectum. Laporotomy revealed colovaginal anastomosis, which was corrected accordingly. Patient had an uneventful recovery. Conclusion Inadvertent formation of colovaginal anastomosis associated with a rectovaginal fistula is a rare complication caused by the operator's error. The present case again highlights the importance of ensuring that the posterior wall of vagina is away from the staple line.

  2. Influence of stapling the intersegmental planes on lung volume and function after segmentectomy.

    Science.gov (United States)

    Tao, Hiroyuki; Tanaka, Toshiki; Hayashi, Tatsuro; Yoshida, Kumiko; Furukawa, Masashi; Yoshiyama, Koichi; Okabe, Kazunori

    2016-10-01

    Dividing the intersegmental planes with a stapler during pulmonary segmentectomy leads to volume loss in the remnant segment. The aim of this study was to assess the influence of segment division methods on preserved lung volume and pulmonary function after segmentectomy. Using image analysis software on computed tomography (CT) images of 41 patients, the ratio of remnant segment and ipsilateral lung volume to their preoperative values (R-seg and R-ips) was calculated. The ratio of postoperative actual forced expiratory volume in 1 s (FEV1) and forced vital capacity (FVC) per those predicted values based on three-dimensional volumetry (R-FEV1 and R-FVC) was also calculated. Differences in actual/predicted ratios of lung volume and pulmonary function for each of the division methods were analysed. We also investigated the correlations of the actual/predicted ratio of remnant lung volume with that of postoperative pulmonary function. The intersegmental planes were divided by either electrocautery or with a stapler in 22 patients and with a stapler alone in 19 patients. Mean values of R-seg and R-ips were 82.7 (37.9-140.2) and 104.9 (77.5-129.2)%, respectively. The mean values of R-FEV1 and R-FVC were 103.9 (83.7-135.1) and 103.4 (82.2-125.1)%, respectively. There were no correlations between the actual/predicted ratio of remnant lung volume and pulmonary function based on the division method. Both R-FEV1 and R-FVC were correlated not with R-seg, but with R-ips. Stapling does not lead to less preserved volume or function than electrocautery in the division of the intersegmental planes. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  3. [Billroth I anastomosis with biodegradable anastomosis ring in the animal model].

    Science.gov (United States)

    Dietz, U A; Debus, E S; Hirt, A L; Czeczko, N G; Nassif, P A; Repka, J C; Malafaia, S; Geiger, D; Thiede, A

    1999-01-01

    In the present study, the Billroth-I anastomosis with the biofragmentable anastomosis ring was examined in dogs. 24 dogs were randomized into a group of manual suturing (n = 12) and a BAR-group (n = 12). In the group of manual suturing, a distal gastric resection and gastroduodenostomy with sero-submucous suture was performed. In the BAR-group, the distal gastric resection was done with the linear stapler PLC-75, whereby the BAR gastroduodenostomy crossed the stapling line. The dogs were evaluated on p.o. days 4, 14, and 30 and tested for bursting strength and bursting location, appearance of mucosa, hydroxyprolin concentration, and histologic features. There was no functional disorder in the gastrointestinal transit in any animal; in summary with regard to the various parameters, the crossing of BAR and stapling line does not represent any additional risk factor in the Billroth-I anastomosis in dogs.

  4. Connective tissue graft as a biological barrier for guided tissue regeneration in intrabony defects: a histological study in dogs.

    Science.gov (United States)

    Ribeiro, Fernando Salimon; Pontes, Ana Emília Farias; Zuza, Elizangela Partata; da Silva, Vanessa Camila; Lia, Raphael Carlos Comelli; Marcantonio Junior, Elcio

    2015-06-01

    The use of the autogenous periosteal graft as biological barrier has been proposed for periodontal regeneration. The aim of this study was to evaluate the histometric findings of the subepithelial connective tissue graft as barrier in intrabony defects compared to a bioabsorbable membrane. Three-walled intrabony defects were created surgically in the mesial aspect of the right and left maxillary canines in five healthy mongrel dogs. The defects were chronified, and two types of barriers were randomly carried out for guided tissue regeneration in a split-mouth design: the test group with a subepithelial connective tissue graft and the control group with a bioabsorbable membrane. The specimens were processed for histometric analyses of the epithelium (E), connective tissue (CT), newly formed cementum (NC), new bone (NB), and total newly formed tissues (NFT). The test side showed smaller mean of NC (3.6 ± 1.2), NB (2.1 ± 0.7), and NFT (7.7 ± 0.8) than the control group (NC 7.3 ± 0.5; NB 5.3 ± 1.3; NFT 10.1 ± 2.2; P  0.05) and CT (test 2.5 ± 1.1; control 2.0 ± 0.5; P > 0.05) between groups. The bioabsorbable membrane was more effective in maintaining the space for periodontal regeneration than periosteal connective graft when used as barrier. The bioabsorbable membrane showed more favorable regenerative results in intrabony defects in dogs than the subepithelial connective tissue graft as biological barrier.

  5. Prostatic Abscess after Stapled Hemorrhoidopexy Caused by ESBL Extended Spectrum Beta Lactamase Producing Klebsiella pneumoniae: An Additional Challenge to Postoperative Sepsis

    Directory of Open Access Journals (Sweden)

    Asem Saleh

    2017-01-01

    Full Text Available Postoperative septic complications of hemorrhoids surgical interventions are rare, but very serious with high mortality rate. Early diagnosis and prompt therapy are essential to save patient’s life. There are a good number of articles and case reports about these septic complications. We are presenting a case report of a prostatic abscess caused by extended spectrum beta lactamase (ESBL producing Klebsiella pneumoniae after hemorrhoidopexy. Our patient was a healthy middle aged Saudi male who has no significant medical history apart from morbid obesity and recurrent urinary tract infections. ESBL producing K. pneumoniae could be detected only after aspiration of the prostatic abscess, but proper antibiotic was introduced intravenously on admission before culture of aspirate of the abscess was available. Antibiotic was continued for 30 days and abscess resolved completely. In our electronic search, we could not find any case report of prostatic abscess after stapled hemorrhoidopexy caused by ESBL producing organism. This is an additional challenge for treating physicians as these organisms are sensitive only to one group of antibiotics (carbapenem group.

  6. Investigation of the best suture pattern to close a stuffed Christmas turkey.

    Science.gov (United States)

    Verwilghen, D; Busoni, V; van Galen, G; Wilke, M

    Instructions on how to debone and stuff a turkey are available, but what is the best way to close it up? A randomised trial involving 15 turkeys was performed in order to evaluate skin disruption scores and cosmetic outcomes following the use of different suture patterns. Turkeys were deboned, stuffed and cooked according to guidelines of the US Department of Agriculture Food Safety and Inspection Services. After stuffing, they were randomly assigned to one of five closure groups: simple continuous Lembert; simple continuous Cushing; simple continuous Utrecht; simple continuous; or staples. Turkeys were cooked at 180 °C for two hours ensuring core temperature reached 75 °C. Suture line integrity was evaluated after removal of the sutures and the cosmetic aspect was graded. Before cooking, the Utrecht pattern and skin staples offered the best cosmetic result. After removal of the sutures, the skin remained intact only in the stapled group. All other suture patterns disrupted the skin after removal of the sutures, rendering the turkey less cosmetically appealing for serving. Closure of a stuffed turkey was best performed using skin staples to achieve the best cosmetic results. Using this technique you will be able to impress family and friends at a Christmas dinner, and finally show them your surgical skills.

  7. A pragmatic, multicentre, randomised controlled trial comparing stapled haemorrhoidopexy to traditional excisional surgery for haemorrhoidal disease (eTHoS): study protocol for a randomised controlled trial.

    Science.gov (United States)

    Watson, Angus J M; Bruhn, Hanne; MacLeod, Kathleen; McDonald, Alison; McPherson, Gladys; Kilonzo, Mary; Norrie, John; Loudon, Malcolm A; McCormack, Kirsty; Buckley, Brian; Brown, Steven; Curran, Finlay; Jayne, David; Rajagopal, Ramesh; Cook, Jonathan A

    2014-11-11

    Current interventions for haemorrhoidal disease include traditional haemorrhoidectomy (TH) and stapled haemorrhoidopexy (SH) surgery. However, uncertainty remains as to how they compare from a clinical, quality of life (QoL) and economic perspective. The study is therefore designed to determine whether SH is more effective and more cost-effective, compared with TH. eTHoS (either Traditional Haemorrhoidectomy or Stapled Haemorrhoidopexy for Haemorrhoidal Disease) is a pragmatic, multicentre, randomised controlled trial. Currently, 29 secondary care centres are open to recruitment. Patients, aged 18 year or older, with circumferential haemorrhoids grade II to IV, are eligible to take part. The primary clinical and economic outcomes are QoL profile (area under the curve derived from the EuroQol Group's 5 Dimension Health Status Questionnaire (EQ-5D) at all assessment points) and incremental cost per quality adjusted life year (QALY) based on the responses to the EQ-5D at 24 months. The secondary outcomes include a comparison of the SF-36 scores, pain and symptoms sub-domains, disease recurrence, complication rates and direct and indirect costs to the National Health Service (NHS). A sample size of n =338 per group has been calculated to provide 90% power to detect a difference in the mean area under the curve (AUC) of 0.25 standard deviations derived from EQ-5D score measurements, with a two-sided significance level of 5%. Allowing for non-response, 400 participants will be randomised per group. Randomisation will utilise a minimisation algorithm that incorporates centre, grade of haemorrhoidal disease, baseline EQ-5D score and gender. Blinding of participants and outcome assessors is not attempted. This is one of the largest trials of its kind. In the United Kingdom alone, 29,000 operations for haemorrhoidal disease are done annually. The trial is therefore designed to give robust evidence on which clinicians and health service managers can base management decisions

  8. Novel double-stapling technique for distal oesophageal resection and oesophago-jejunal anastomosis.

    Science.gov (United States)

    Gentilli, Sergio; Portigliotti, Luca; Davoli, Fabio; Roncon, Alberto; Rena, Ottavio; Oldani, Alberto

    2016-01-01

    The restoration of the digestive tract by performing an esophago-jejunal anastomosis (EJA) is a crucial step of the total gastric and distal esophagus surgical resection for esophago-gastric junction (EGJ) cancer. We have already ideated and tested on a cadaver model an innovative technique which could be useful to minimize the risk of complications related to the phase of securing the anvil of the circular stapler prior to perform the EJA. This surgical technique was derived from the well-known "double-stapling Knight and Griffen" one that was described for the rectal resection. We used the following described technique in 20 patients with EGJ cancer and it is efficient, reliable, safe, easy to learn and easy to perform. From August 2014 to May 2015, 20 patients (14 male and 6 female) underwent surgery for esophagogastric junction cancer: In all patients a distal esophageal resection and total gastrectomy was performed. Through the trans-hiatal access, the free margins of the esophageal stump were suspended and the anvil of a circular stapler on a new dedicated and registered support bar was inserted into the lumen. Subsequently, the linear suturing stapler is closed over the bar and then fired to suture the distal stump of the esophagus; after the confirmation of a negative margin, the bar is retracted and the push-rod of the anvil is pulled out through the linear suture. Finally, the anastomosis is performed with the classic technique by using a circular stapler. No postoperative mortality occurred; postoperative course has been uneventful for 18 patients. One patient developed anastomotic fistula that has been treated conservatively with endoscopic prothesis, removed after 20 days. One patient developed in 3 POD myocardial infarction Mean Hospital stay has been 14 days (range 7-20 days). The aim of our new procedure is the insertion the anvil of a common circular stapler without handsewn securing; this is to reduce the technical difficulties related to the hand

  9. Consuming the savings : Water Conservation in a Vegetation Barrier System at the Central Plateau in Burkina Faso

    NARCIS (Netherlands)

    Spaan, W.P.

    2003-01-01

    The vast majority of land users at the Central Plateau of Burkina Faso make a living by farming small plots, where mainly staple crops are produced for subsistence use. Both area interventions and line interventions comprising indigenous techniques as well as introduced techniques can be encountered

  10. Folic acid levels in some food staples in Ireland are on the decline: implications for passive folic acid intakes?

    Science.gov (United States)

    Kelly, F; Gibney, E R; Boilson, A; Staines, A; Sweeney, M R

    2016-06-01

    Neural tube defects are largely preventable by the maternal periconceptual consumption of folic acid. The aim of this study was to examine the levels of synthetic folic acid in foods and the range of food stuffs with added folic acid available to consumers in Ireland at the current time. Three audits of fortified foods available in supermarkets in the Republic of Ireland were conducted. Researchers visited supermarkets and obtained folic acid levels from nutrition labels in 2004, 2008 and 2013/4. Levels were compared using MS Excel. The profile of foods fortified with folic acid in 2013/4 has changed since 2004. The percentage of foods fortified with folic acid has decreased as has the level of added folic acid in some food staples, such as fat/dairy spreads. Bread, milk and spreads no longer contain as much folic acid as previously (2004 and 2008). This may contribute to a decrease in folate intake and therefore may contribute to an increase in NTD rates. Research on current blood concentrations of folate status markers is now warranted. © The Author 2015. Published by Oxford University Press on behalf of Faculty of Public Health. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  11. Is the staple diet eaten in Medawachchiya, Sri Lanka, a predisposing factor in the development of chronic kidney disease of unknown etiology? - A comparison based on urinary β2-microglobulin measurements.

    Science.gov (United States)

    Siriwardhana, E A Ranga I E; Perera, Ponnumperuma A J; Sivakanesan, Ramiah; Abeysekara, Thilak; Nugegoda, Danaseela B; Weerakoon, Kosala G A D

    2014-07-02

    Exact mechanism of causation of chronic kidney disease of unknown etiology (CKDu) in Sri Lanka is not described to date, despite the identification of possible multiple risk factors. Questions have been raised as to why only some are affected while others remain intact, though they are inhabitants of the same locality. Comparative studies were carried out, assessing urinary β2 microglobulin (β2m) and the dietary patterns of CKDu patients and age sex matched non-CKDu subjects. Urinary β2m levels of spot urine samples were analyzed using the Enzyme-linked Immunosorbent assay (ELISA) and dietary patterns were studied using twenty four hour dietary recalls and frequency consumption of foods of animal origin performed on three occasions at six months intervals within a period of one and half years. The mean urinary β2m level of CKDu patients from Medawachchiya was significantly (pCKDu subjects. The mean urinary β2m level of the non-CKDu subjects was within the reference limits for spot urine samples (0 - 0.3 μg/mL). White raw rice was the staple diet of both CKDu patients and non-CKDu subjects and the level of consumption was almost the same. The consumption of fresh water fish products of CKDu patients under high (14, 14%), moderate (36, 36%), low (26, 26%) and less (20, 20%) categories did not show significant variations (p>0.05) compared to non-CKDu subjects. Staple food in diet and the consumption pattern of CKDu patients from Medawachchiya were similar to that of non-CKDu subjects from the same area despite their urinary β2m concentration being significantly higher.

  12. Stapled Mesh stomA Reinforcement Technique (SMART) in the prevention of parastomal hernia: a single-centre experience.

    Science.gov (United States)

    Ng, Z Q; Tan, P; Theophilus, M

    2017-06-01

    Parastomal hernia remains a frequent complication following creation of an abdominal stoma. Previous interests have centred around the exploration of methods to repair; however, prophylactic mesh placement has demonstrated its efficacy in reduction of parastomal hernia. The aim of this retrospective analysis was to evaluate the outcomes of Stapled Mesh stomA Reinforcement Technique (SMART) in terms of parastomal hernia occurrence rate and mesh-related complications. All patients operated with an abdominal perineal resection or Hartmann's procedure with SMART from November 2013 to March 2016 were included. Patient demographics, operative details and stoma-related symptoms were collected. Patients were examined clinically by the medical team and also reviewed independently by a specialist stoma care nurse for signs of stoma-related complications. As part of oncological follow-up, CT scans were available for review for evidence of parastomal herniation. 14 patients (mean age 76 years) were included in the analysis. All the SMART cases were successfully completed with no intraoperative or immediate post-operative complications. No cases of mesh-related complications such as infection, immediate stomal prolapse, stenosis, retraction, stomal obstruction, mesh erosion or fistulation were observed. No mesh removal was required. There were two cases of parastomal hernia detected on CT scan. Both cases have remained asymptomatic no intervention was required at this stage. Median follow-up was 24 months. Our medium-term experience has demonstrated the efficacy of SMART in the reduction of parastomal hernia occurrence. With appropriate learning curve, parastomal hernia can be prevented.

  13. Preoperative Detection of Sarcopenic Obesity Helps to Predict the Occurrence of Gastric Leak After Sleeve Gastrectomy.

    Science.gov (United States)

    Gaillard, Martin; Tranchart, Hadrien; Maitre, Sophie; Perlemuter, Gabriel; Lainas, Panagiotis; Dagher, Ibrahim

    2018-03-02

    Sleeve gastrectomy (SG) has become the primary procedure for many bariatric teams and staple-line leak represents its most feared complication. Sarcopenic obesity combines the risks of obesity and depleted lean mass leading possibly to an inferior surgical outcome after abdominal surgery. The aim of this study was to evaluate the existence of a potential link between radiologically determined sarcopenic obesity and staple-line leak risk after SG. A retrospective analysis of a prospective database was performed in consecutive patients undergoing SG as primary procedure. Total psoas muscles (TPA) and total visible muscles (TMA) areas were measured on a preoperative computed tomography (CT). Sarcopenia was defined as lowest tertile of skeletal muscular mass indexes (muscular areas over square of height) in each gender (using TPA or TMA). Multivariate analysis was performed to determine preoperative risk factors for staple-line leak. During the study period, 205 patients were included in the analysis. Median BMI was 40.8 kg/m 2 (34.2-49.6), and 9 patients (4.4%) presented a gastric leak. The sex-specific cut-offs for skeletal muscular mass index according to TPA were 8.2 cm 2 /m 2 for men and 6.08 cm 2 /m 2 for women. After multivariate analysis, preoperative weight (OR = 1043) and sarcopenia (TPA) (OR = 5204) were independent predictive factors for gastric leak. The present series suggests that CT scan-determined sarcopenic obesity is associated with increased risk of gastric leak after SG. This preoperatively radiological examination would be a useful clinical tool to tailor patient management according to gastric leak risk.

  14. The U-line line balancing problem

    NARCIS (Netherlands)

    Miltenburg, G.J.; Wijngaard, J.

    1994-01-01

    The traditional line balancing (LB) problem considers a production line in which stations are arranged consecutively in a line. A balance is determined by grouping tasks into stations while moving forward (or backward) through a precedence network. Recently many production lines are being arranged

  15. Antiviral activity of α-helical stapled peptides designed from the HIV-1 capsid dimerization domain

    Directory of Open Access Journals (Sweden)

    Cowburn David

    2011-05-01

    Full Text Available Abstract Background The C-terminal domain (CTD of HIV-1 capsid (CA, like full-length CA, forms dimers in solution and CTD dimerization is a major driving force in Gag assembly and maturation. Mutations of the residues at the CTD dimer interface impair virus assembly and render the virus non-infectious. Therefore, the CTD represents a potential target for designing anti-HIV-1 drugs. Results Due to the pivotal role of the dimer interface, we reasoned that peptides from the α-helical region of the dimer interface might be effective as decoys to prevent CTD dimer formation. However, these small peptides do not have any structure in solution and they do not penetrate cells. Therefore, we used the hydrocarbon stapling technique to stabilize the α-helical structure and confirmed by confocal microscopy that this modification also made these peptides cell-penetrating. We also confirmed by using isothermal titration calorimetry (ITC, sedimentation equilibrium and NMR that these peptides indeed disrupt dimer formation. In in vitro assembly assays, the peptides inhibited mature-like virus particle formation and specifically inhibited HIV-1 production in cell-based assays. These peptides also showed potent antiviral activity against a large panel of laboratory-adapted and primary isolates, including viral strains resistant to inhibitors of reverse transcriptase and protease. Conclusions These preliminary data serve as the foundation for designing small, stable, α-helical peptides and small-molecule inhibitors targeted against the CTD dimer interface. The observation that relatively weak CA binders, such as NYAD-201 and NYAD-202, showed specificity and are able to disrupt the CTD dimer is encouraging for further exploration of a much broader class of antiviral compounds targeting CA. We cannot exclude the possibility that the CA-based peptides described here could elicit additional effects on virus replication not directly linked to their ability to bind

  16. Projective analysis of staple food crop productivity in adaptation to future climate change in China.

    Science.gov (United States)

    Zhang, Qing; Zhang, Wen; Li, Tingting; Sun, Wenjuan; Yu, Yongqiang; Wang, Guocheng

    2017-08-01

    Climate change continually affects our capabilities to feed the increasing population. Rising temperatures have the potential to shorten the crop growth duration and therefore reduce crop yields. In the past decades, China has successfully improved crop cultivars to stabilize, and even lengthen, the crop growth duration to make use of increasing heat resources. However, because of the complex cropping systems in the different regions of China, the possibility and the effectiveness of regulating crop growth duration to reduce the negative impacts of future climate change remain questionable. Here, we performed a projective analysis of the staple food crop productivity in double-rice, wheat-rice, wheat-maize, single-rice, and single-maize cropping systems in China using modeling approaches. The results indicated that from the present to the 2040s, the warming climate would shorten the growth duration of the current rice, wheat, and maize cultivars by 2-24, 11-13, and 9-29 days, respectively. The most significant shortening of the crop growth duration would be in Northeast China, where single-rice and single-maize cropping dominates the croplands. The shortened crop growth duration would consequently reduce crop productivity. The most significant decreases would be 27-31, 6-20, and 7-22% for the late crop in the double-rice rotation, wheat in the winter wheat-rice rotation, and single maize, respectively. However, our projection analysis also showed that the negative effects of the warming climate could be compensated for by stabilizing the growth duration of the crops via improvement in crop cultivars. In this case, the productivity of rice, wheat, and maize in the 2040s would increase by 4-16, 31-38, and 11-12%, respectively. Our modeling results implied that the possibility of securing future food production exists by adopting proper adaptation options in China.

  17. Projective analysis of staple food crop productivity in adaptation to future climate change in China

    Science.gov (United States)

    Zhang, Qing; Zhang, Wen; Li, Tingting; Sun, Wenjuan; Yu, Yongqiang; Wang, Guocheng

    2017-08-01

    Climate change continually affects our capabilities to feed the increasing population. Rising temperatures have the potential to shorten the crop growth duration and therefore reduce crop yields. In the past decades, China has successfully improved crop cultivars to stabilize, and even lengthen, the crop growth duration to make use of increasing heat resources. However, because of the complex cropping systems in the different regions of China, the possibility and the effectiveness of regulating crop growth duration to reduce the negative impacts of future climate change remain questionable. Here, we performed a projective analysis of the staple food crop productivity in double-rice, wheat-rice, wheat-maize, single-rice, and single-maize cropping systems in China using modeling approaches. The results indicated that from the present to the 2040s, the warming climate would shorten the growth duration of the current rice, wheat, and maize cultivars by 2-24, 11-13, and 9-29 days, respectively. The most significant shortening of the crop growth duration would be in Northeast China, where single-rice and single-maize cropping dominates the croplands. The shortened crop growth duration would consequently reduce crop productivity. The most significant decreases would be 27-31, 6-20, and 7-22% for the late crop in the double-rice rotation, wheat in the winter wheat-rice rotation, and single maize, respectively. However, our projection analysis also showed that the negative effects of the warming climate could be compensated for by stabilizing the growth duration of the crops via improvement in crop cultivars. In this case, the productivity of rice, wheat, and maize in the 2040s would increase by 4-16, 31-38, and 11-12%, respectively. Our modeling results implied that the possibility of securing future food production exists by adopting proper adaptation options in China.

  18. An Endoscopic Nasomediastinal Approach to a Mediastinal Abscess Developing after Zenker's Diverticulectomy

    Science.gov (United States)

    Gundogdu, Kemal; Eminler, Ahmet Tarik; Parlak, Erkan; Cakmak, Guner

    2017-01-01

    Zenker's diverticulum is the most frequent symptomatic diverticulum of the esophagus, but the prevalence is <0.1%. The optimal treatment is surgery. Here, we present a nasomediastinal drainage approach to treatment of a mediastinal abscess, developing in the late postoperative period and attributable to leakage from the staple line. PMID:28831318

  19. An Endoscopic Nasomediastinal Approach to a Mediastinal Abscess Developing after Zenker’s Diverticulectomy

    Directory of Open Access Journals (Sweden)

    Fatih Altintoprak

    2017-01-01

    Full Text Available Zenker’s diverticulum is the most frequent symptomatic diverticulum of the esophagus, but the prevalence is <0.1%. The optimal treatment is surgery. Here, we present a nasomediastinal drainage approach to treatment of a mediastinal abscess, developing in the late postoperative period and attributable to leakage from the staple line.

  20. Doppler-Guided Transanal Hemorrhoidal Dearterialization (DG-THD) Versus Stapled Hemorrhoidopexy (SH) in the Treatment of Third-Degree Hemorrhoids: Clinical Results at Short and Long-Term Follow-Up.

    Science.gov (United States)

    Leardi, S; Pessia, B; Mascio, M; Piccione, F; Schietroma, M; Pietroletti, R

    2016-11-01

    The stapled hemorrhoidopexy (SH) and the Doppler-guided transanal hemorrhoidal dearterialization (DG-THD) are minimally invasive procedures for the surgical treatment of hemorrhoids. This study aims to verify the efficacy of the DG-THD versus the SH in the treatment of third-degree hemorrhoids. One hundred consecutive patients were causally allocated to either procedure, obtaining two groups of 50 pts. A clinical examination was performed at 3, 7, 15, and 30 days after the operation. Quality of life, anal symptoms, recurrence of hemorrhoids, and reoperation were assessed by means of a questionnaire and of a clinical examination at long-term follow-up (7.0 year average). At short-term follow-up, the median postoperative pain score was significantly lower in DG-THD group compared to SH group, (V.A.S 2 vs 6; t = 2.65, p hemorrhoids.

  1. OBTENCIÓN, ELECTRODEPOSICIÓN Y CARACTERIZACIÓN DE UN RECUBRIMIENTO POLIMÉRICO BIOABSORBIBLE A PARTIR DE ÁCIDO L - LÁCTICO PARA APLICACIONES BIOMÉDICAS SYNTHESIS, ELECTRODEPOSITION AND CHARACTERIZATION OF A BIOABSORBABLE POLYMER COATING FROM L-LACTIC ACID FOR BIOMEDICAL APPLICATIONS

    Directory of Open Access Journals (Sweden)

    Diana Carolina Parada Quinayá

    2009-12-01

    Full Text Available El ácido poli (L-láctico (APL ha sido usado ampliamente en aplicaciones biomédicas como suturas e implantes bioabsorbibles debido a su capacidad para permitir el crecimiento controlado de tejido biológico durante su biodegradación controlada. En este trabajo se obtuvo APL a partir de la policondensación de ácido láctico en presencia de un catalizador de zinc metálico en condiciones de vacío y atmósfera inerte. Se variaron las concentraciones de Zn++ y el tiempo de polimerización con el fin de obtener varias muestras que fueron caracterizadas mediante espectroscopia infrarroja (IR, calorimetría diferencial de barrido (DSC, análisis termogravimétrico (TGA y microscopia electrónica de barrido (SEM. Se obtuvieron recubrimientos poliméricos por electrodeposición catódica sobre sustratos de Ti6Al4V, usando una celda electrolítica con capacidad de 200 ml y dos ánodos de grafito cuya área expuesta fue de 12,57 cm². El electrolito consistió en una disolución 30:70 v/v de APL y acetona. Las variables involucradas fueron: voltaje, tiempo, temperatura, velocidad de agitación y las condiciones de preparación del polímero. Los recubrimientos obtenidos se caracterizaron mediante microscopia óptica y ataque químico. Los resultados revelaron la obtención de APL y la influencia del iniciador de Zn++, el cual promovió la migración y formación de grupos catiónicos que lograron neutralizarse y condensarse sobre Ti6Al4V bajo cargas catódicas. El análisis térmico mostró que en el rango de temperatura, entre 25 °C - 50 °C, no hubo variaciones importantes en la degradación térmica, indicando que el material podría ser utilizado para recubrir implantes ortopédicos.Poli (L-lactic (PLA has been used broadly in biomedical applications, such as sutures and bioadsorbable implant due to its capacity to allow the controlled growth of the biological tissue during their controlled biodegradation. In this work, a material polymeric PLA

  2. Intraoperative leak testing has no correlation with leak after laparoscopic sleeve gastrectomy.

    Science.gov (United States)

    Sethi, Monica; Zagzag, Jonathan; Patel, Karan; Magrath, Melissa; Somoza, Eduardo; Parikh, Manish S; Saunders, John K; Ude-Welcome, Aku; Schwack, Bradley F; Kurian, Marina S; Fielding, George A; Ren-Fielding, Christine J

    2016-03-01

    Staple line leak is a serious complication of sleeve gastrectomy. Intraoperative methylene blue and air leak tests are routinely used to evaluate for leak; however, the utility of these tests is controversial. We hypothesize that the practice of routine intraoperative leak testing is unnecessary during sleeve gastrectomy. A retrospective cohort study was designed using a prospectively collected database of seven bariatric surgeons from two institutions. All patients who underwent sleeve gastrectomy from March 2012 to November 2014 were included. The performance of intraoperative leak testing and the type of test (air or methylene blue) were based on surgeon preference. Data obtained included BMI, demographics, comorbidity, presence of intraoperative leak test, result of test, and type of test. The primary outcome was leak rate between the leak test (LT) and no leak test (NLT) groups. SAS version 9.4 was used for univariate and multivariate analyses. A total of 1550 sleeve gastrectomies were included; most were laparoscopic (99.8%), except for one converted and two open cases. Routine intraoperative leak tests were performed in 1329 (85.7%) cases, while 221 (14.3%) did not have LTs. Of the 1329 cases with LTs, there were no positive intraoperative results. Fifteen (1%) patients developed leaks, with no difference in leak rate between the LT and NLT groups (1 vs. 1%, p = 0.999). After adjusting for baseline differences between the groups with a propensity analysis, the observed lack of association between leak and intraoperative leak test remained. In this cohort, leaks presented at a mean of 17.3 days postoperatively (range 1-67 days). Two patients with staple line leaks underwent repeat intraoperative leak testing at leak presentation, and the tests remained negative. Intraoperative leak testing has no correlation with leak due to laparoscopic sleeve gastrectomy and is not predictive of the later development of staple line leak.

  3. Clinical comparison of Bio-Oss plus 10% collagen with a bioabsorbable collagen barrier or coronally advanced flap in treatment of mandibular molars class II furcation defects

    Directory of Open Access Journals (Sweden)

    Radafshar G.

    2008-10-01

    Full Text Available "nBackground and Aim: Furcation defects are one of the most challenging problems in periodontal therapy. Regenerative treatment significantly improves the prognosis of the involved teeth. The aim of this study was to compare Bio-Oss plus 10% collagen in combination with either a bioabsorbable collagen barrier (BO/GTR, or coronally advanced flap (BO/CF, in treating human mandibular class II furcation defects. "nMaterials and Methods: This clinical trial included 10 patients with 10 pairs of similar periodontal defects. Each defect was randomly assigned to treatment with BO/CF or BO/GTR. Following basic therapy, baseline measurements were recorded including probing pocket depth (PPD,closed horizontal probing depth (CHPD, clinical attachment level (CAL, and gingival margin position (CEJ-GM, together with plaque and gingival indices. Hard tissue measurements were performed during surgery to determine alveolar crestal height (CEJ-AC, and vertical and horizontal open probing depth (OVPD, OHPD.After 6 months, all sites were re-entered and soft and hard tissue measurements were recorded. "nResults: Both surgical procedures significantly reduced probing depth and improved clinical attachment levels, with no significant difference between groups. Gingival margin position (CEJ-GM, was improved in the BO/CF group (0.66±0.51 mm, p<0.05, but not statistically different from BO/GTR group in which remained relatively constant (0.00±0.81 mm. Vertical defect resolution was significant in each groups (BO/CF:3.17±1.47 mm, BO/GTR:3.33±0.51mm. Horizontal defect resolution was also significant with either procedure (BO/CF:3.67±1.31 mm, BO/GTR:3.80±1.83 mm, with no statistically significant difference between groups. Data were analyzed with wilcoxon and Mann-Whitney tests with p<0.05 as the level of significance. "nConclusion: Based on the results of this study, treatment of mandibular class II furcation defects with both procedures resulted in statistically

  4. Consuming the savings: Water conservation in a vegetation barrier system at the Central Plateau in Burkina Faso

    OpenAIRE

    Spaan, W.

    2003-01-01

    The vast majority of land users at the Central Plateau of Burkina Faso make a living by farming small plots, where mainly staple crops are produced for subsistence use. Both area interventions and line interventions comprising indigenous techniques as well as introduced techniques can be encountered at the Central Plateau and have proved to be effective. There is a preference for semi-permeable line measures that slow down runoff and prevent water logging in wet periods.In order to ascertain ...

  5. Heterosis and correlation in interspecific and intraspecific hybrids of cotton.

    Science.gov (United States)

    Munir, S; Hussain, S B; Manzoor, H; Quereshi, M K; Zubair, M; Nouman, W; Shehzad, A N; Rasul, S; Manzoor, S A

    2016-06-24

    Interspecific and intraspecific hybrids show varying degrees of heterosis for yield and yield components. Yield-component traits have complex genetic relationships with each other. To determine the relationship of yield-component traits and fiber traits with seed cotton yield, six lines (Bt. CIM-599, CIM-573, MNH-786, CIM-554, BH-167, and GIZA-7) and three test lines (MNH-886, V4, and CIM-557) were crossed in a line x tester mating design. Heterosis was observed for seed cotton yield, fiber traits, and for other yield-component traits. Heterosis in interspecific hybrids for seed cotton yield was more prominent than in intraspecific hybrids. The interspecific hybrid Giza-7 x MNH-886 had the highest heterosis (114.77), while among intraspecific hybrids, CIM-554 x CIM-557 had the highest heterosis (61.29) for seed cotton yield. A major trait contributing to seed cotton yield was bolls/plant followed by boll weight. Correlation studies revealed that bolls/plant, boll weight, lint weight/boll, lint index, seed index, lint/seed, staple length, and staple strength were significantly and positively associated with seed cotton yield. Selection based on boll weight, boll number, lint weight/boll, and lint index will be helpful for improving cotton seed yield.

  6. Pro-apoptotic and anti-proliferative effects of corn silk extract on human colon cancer cell lines

    OpenAIRE

    Guo, Hao; Guan, Hong; Yang, Wenqin; Liu, Han; Hou, Huiling; Chen, Xue; Liu, Zhenyan; Zang, Chuangang; Liu, Yuchao; Liu, Jicheng

    2016-01-01

    Corn silk is an economically and nutritionally significant natural product as it represents a staple food for a large proportion of the world population. This study investigated the anticancer activity of corn silk extract in human colon cancer cells and human gastric cancer cells. Following treatment with corn silk extract, certain apoptosis-related events were observed, including inhibition of cell proliferation, loss of mitochondrial membrane potential (??m), release of Ca2+ and release of...

  7. An Assessment of the Impact of Fortification of Staples and Condiments on Micronutrient Intake in Young Vietnamese Children

    Directory of Open Access Journals (Sweden)

    Jacques Berger

    2012-08-01

    Full Text Available Targeted fortification programs for infants and young children are an effective strategy to prevent micronutrient deficiencies in developing countries, but the role of large-scale fortification of staple foods and condiments is less clear. Dietary modeling in children aged 6–60 months was undertaken, based on food consumption patterns described in the 2009 national food consumption survey, using a 24-h recall method. Consumption data showed that the median intake of a child for iron, vitamin A and zinc, as a proportion of the Vietnamese Recommended Dietary Allowance (VRDA, is respectively 16%–48%, 14%–49% and 36%–46%, (depending on the age group. Potential fortification vehicles, such as rice, fish/soy sauces and vegetable oil are consumed daily in significant amounts (median: 170 g/capita/day, 4 g/capita/day and 6 g/capita/day, respectively by over 40% of the children. Vegetable oil fortification could contribute to an additional vitamin A intake of 21%–24% of VRDA recommended nutrient intake, while fortified rice could support the intakes of all the other micronutrients (14%–61% for iron, 4%–11% for zinc and 33%–49% of folate requirements. Other food vehicles, such as wheat flour, which is consumed by 16% of children, could also contribute to efforts to increase micronutrient intakes, although little impact on the prevalence of micronutrient deficiencies can be expected if used alone. The modeling suggests that fortification of vegetable oil, rice and sauces would be an effective strategy to address micronutrient gaps and deficiencies in young children.

  8. Cost Effectiveness of Stapled Haemorrhoidopexy and Traditional Excisional Surgery for the Treatment of Haemorrhoidal Disease.

    Science.gov (United States)

    Kilonzo, Mary M; Brown, Steven R; Bruhn, Hanne; Cook, Jonathan A; Hudson, Jemma; Norrie, John; Watson, Angus J M; Wood, Jessica

    2017-08-25

    Our objective was to compare the cost effectiveness of stapled haemorrhoidopexy (SH) and traditional haemorrhoidectomy (TH) in the treatment of grade II-IV haemorrhoidal disease from the perspective of the UK national health service. An economic evaluation was conducted alongside an open, two-arm, parallel-group, pragmatic, multicentre, randomised controlled trial conducted in several hospitals in the UK. Patients were randomised into either SH or TH surgery between January 2011 and August 2014 and were followed up for 24 months. Intervention and subsequent resource use data were collected using case review forms and questionnaires. Benefits were collected using the EQ-5D-3L (EuroQoL-five dimensions-three levels) instrument. The primary economic outcome was incremental cost measured in pounds (£), year 2016 values, relative to the incremental benefit, which was estimated using quality-adjusted life-years (QALYs). Cost and benefits accrued in the second year were discounted at 3.5%. The base-case analysis was based on imputed data. Uncertainty was explored using univariate sensitivity analyses. Participants (n = 777) were randomised to SH (n = 389) or TH (n = 388). The mean cost of SH was £337 (95% confidence interval [CI] 251-423) higher than that of TH and the mean QALYs were -0.070 (95% CI -0.127 to -0.011) lower than for TH. The base-case cost-utility analysis indicated that SH has zero probability of being cost effective at both the £20,000 and the £30,000 threshold. Results from the sensitivity analyses were similar to those from the base-case analysis. The evidence suggests that, on average, the total mean costs over the 24-month follow-up period were significantly higher for the SH arm than for the TH arm. The QALYs were also, on average, significantly lower for the SH arm. These results were supported by the sensitivity analyses. Therefore, in terms of cost effectiveness, TH is a superior surgical treatment for the management of grade II

  9. Factors Predicting Difficulty of Laparoscopic Low Anterior Resection for Rectal Cancer with Total Mesorectal Excision and Double Stapling Technique.

    Directory of Open Access Journals (Sweden)

    Weiping Chen

    Full Text Available Laparoscopic sphincter-preserving low anterior resection for rectal cancer is a surgery demanding great skill. Immense efforts have been devoted to identifying factors that can predict operative difficulty, but the results are inconsistent.Our study was conducted to screen patients' factors to build models for predicting the operative difficulty using well controlled data.We retrospectively reviewed records of 199 consecutive patients who had rectal cancers 5-8 cm from the anal verge. All underwent laparoscopic sphincter-preserving low anterior resections with total mesorectal excision (TME and double stapling technique (DST. Data of 155 patients from one surgeon were utilized to build models to predict standardized endpoints (operative time, blood loss and postoperative morbidity. Data of 44 patients from other surgeons were used to test the predictability of the built models.Our results showed prior abdominal surgery, preoperative chemoradiotherapy, tumor distance to anal verge, interspinous distance, and BMI were predictors for the standardized operative times. Gender and tumor maximum diameter were related to the standardized blood loss. Temporary diversion and tumor diameter were predictors for postoperative morbidity. The model constructed for the operative time demonstrated excellent predictability for patients from different surgeons.With a well-controlled patient population, we have built a predictable model to estimate operative difficulty. The standardized operative time will make it possible to significantly increase sample size and build more reliable models to predict operative difficulty for clinical use.

  10. Line facilities outline

    International Nuclear Information System (INIS)

    1998-08-01

    This book deals with line facilities. The contents of this book are outline line of wire telecommunication ; development of line, classification of section of line and theory of transmission of line, cable line ; structure of line, line of cable in town, line out of town, domestic cable and other lines, Optical communication ; line of optical cable, transmission method, measurement of optical communication and cable of the sea bottom, Equipment of telecommunication line ; telecommunication line facilities and telecommunication of public works, construction of cable line and maintenance and Regulation of line equipment ; regulation on technique, construction and maintenance.

  11. Médicos residentes podem realizar com segurança e eficiência técnicas de Milligan-Morgan, Ferguson e grampeadores no tratamento cirúrgico das hemorróidas? Can residents safely and efficiently perform Milligan-Morgan, Ferguson and stapled hemorrhoidopexy?

    Directory of Open Access Journals (Sweden)

    Sérgio Carlos Nahas

    2011-09-01

    tempo operatório, enquanto Milligan-Morgan foi correlacionada com maior tempo de hospitalização.BACKGROUND: Surgery for symptomatic hemorrhoids is needed in almost 10% of the patients. Although, literature about the surgical management of hemorrhoidal disease is vast, data concerning hemorrhoidectomy or hemorrhoidopexy performed by training residents is limited. AIM: To analyze the results of these procedures in a teaching institution. METHODS: Data from all patients who underwent surgical treatment for hemorrhoids from 1995 to 2007 in a single institution were retrospectively analyzed. Residents supervised by assisting doctors performed all procedures. Techniques were compared based on operative time, hospital stay, morbidity, and long-term efficacy. RESULTS: Three hundred thirty three patients were included in the study, 182 males (54.6%, with a mean age of 45.3 years (± 12.02. Third degree hemorrhoids were the main indication (81.7%. Milligan-Morgan was the most commonly performed procedure (57%, followed by Ferguson and stapled hemorrhoidopexy. Mean operative time was significantly lower in the stapled hemorrhoidopexy group when compared to the open and closed procedures: 49,4 ± 29.3 min vs. 61.1 ± 26.5 and 67.1 ± 28.3, respectively (p=0.0034. There was no statistically significant difference among the groups regarding postoperative complications or reoperation rate. Length of stay was significantly higher in the Milligan-Morgan group when compared to Ferguson and stapled hemorrhoidopexy (1.41 ± 0.86 days vs. 1.19 ± 0.43 vs. 1.16 ± 0.37 respectively. Symptomatic recurrence, reoperation rates and band ligation usage were similar among groups. CONCLUSION: Residents under supervision can perform Milligan-Morgan, Ferguson and stapled hemorrhoidopexy with low incidence of complications and good long-term results. Stapled hemorrhoidopexy technique was associated with a shorter operative time, while Milligan-Morgan correlated with a longer length of stay.

  12. Similarity law for Widom lines and coexistence lines.

    Science.gov (United States)

    Banuti, D T; Raju, M; Ihme, M

    2017-05-01

    The coexistence line of a fluid separates liquid and gaseous states at subcritical pressures, ending at the critical point. Only recently, it became clear that the supercritical state space can likewise be divided into regions with liquidlike and gaslike properties, separated by an extension to the coexistence line. This crossover line is commonly referred to as the Widom line, and is characterized by large changes in density or enthalpy, manifesting as maxima in the thermodynamic response functions. Thus, a reliable representation of the coexistence line and the Widom line is important for sub- and supercritical applications that depend on an accurate prediction of fluid properties. While it is known for subcritical pressures that nondimensionalization with the respective species critical pressures p_{cr} and temperatures T_{cr} only collapses coexistence line data for simple fluids, this approach is used for Widom lines of all fluids. However, we show here that the Widom line does not adhere to the corresponding states principle, but instead to the extended corresponding states principle. We resolve this problem in two steps. First, we propose a Widom line functional based on the Clapeyron equation and derive an analytical, species specific expression for the only parameter from the Soave-Redlich-Kwong equation of state. This parameter is a function of the acentric factor ω and compares well with experimental data. Second, we introduce the scaled reduced pressure p_{r}^{*} to replace the previously used reduced pressure p_{r}=p/p_{cr}. We show that p_{r}^{*} is a function of the acentric factor only and can thus be readily determined from fluid property tables. It collapses both subcritical coexistence line and supercritical Widom line data over a wide range of species with acentric factors ranging from -0.38 (helium) to 0.34 (water), including alkanes up to n-hexane. By using p_{r}^{*}, the extended corresponding states principle can be applied within

  13. Circular stapled pyloroplasty: a fast and effective technique for pyloric disruption during esophagectomy with gastric pull-up.

    Science.gov (United States)

    Oezcelik, A; DeMeester, S R; Hindoyan, K; Leers, J M; Ayazi, S; Abate, E; Zehetner, J; Hagen, J A; Lipham, J C; DeMeester, T R

    2011-08-01

    The necessity of pyloroplasty after esophagectomy and gastric pull-up is debated. Disadvantages of a standard pyloroplasty include the potential for leak, shortening of the length of the graft, and complexity when done during a minimally invasive procedure. The aim of this study is to report our experience with a novel internal pyloroplasty technique using a circular stapler (CS pyloroplasty), which is applicable for both laparoscopic and open esophagectomy. The records of all patients who underwent an esophagectomy with gastric pull-up and pyloroplasty between 2002 and 2007 were reviewed. The CS pyloroplasty was performed through a lesser curve gastrotomy with a 21-mm CS, while the standard pyloroplasty entailed a longitudinal full thickness incision through the pylorus with mucosal closure in the same direction and a Graham patch. A CS pyloroplasty was performed in 144 and a standard pyloroplasty in 133 patients. The median patient age was 66years, and the median follow-up was 17months, and was similar for both types of pyloroplasty. Routine postoperative videoesophagram was significantly more likely to show a delay in contrast transit through the pylorus after standard pyloroplasty (16% standard vs. 8% CS pyloroplasty, P= 0.03). Significantly more patients had postoperative endoscopy after standard pyloroplasty (40% standard vs. 24% CS pyloroplasty, P= 0.004), but the frequency of pyloric dilatation was similar. There were no leaks with either technique. A circular stapled pyloroplasty is as efficacious as a standard pyloroplasty after esophagectomy with gastric pull-up. Potential advantages include the ease and simplicity of the procedure along with virtually no risk of a leak and no graft shortening. The technique is amenable to both open and minimally invasive procedures. © 2011 Copyright the Authors. Journal compilation © 2011, Wiley Periodicals, Inc. and the International Society for Diseases of the Esophagus.

  14. A new mathematical formulation of the line-by-line method in case of weak line overlapping

    Science.gov (United States)

    Ishov, Alexander G.; Krymova, Natalie V.

    1994-01-01

    A rigorous mathematical proof is presented for multiline representation on the equivalent width of a molecular band which consists in the general case of n overlapping spectral lines. The multiline representation includes a principal term and terms of minor significance. The principal term is the equivalent width of the molecular band consisting of the same n nonoverlapping spectral lines. The terms of minor significance take into consideration the overlapping of two, three and more spectral lines. They are small in case of the weak overlapping of spectral lines in the molecular band. The multiline representation can be easily generalized for optically inhomogeneous gas media and holds true for combinations of molecular bands. If the band lines overlap weakly the standard formulation of line-by-line method becomes too labor-consuming. In this case the multiline representation permits line-by-line calculations to be performed more effectively. Other useful properties of the multiline representation are pointed out.

  15. 76 FR 51367 - China Shipping Container Lines Co., Ltd.; COSCO Container Lines Company Limited; Evergreen Line A...

    Science.gov (United States)

    2011-08-18

    ... FEDERAL MARITIME COMMISSION [Docket No. 11-12] China Shipping Container Lines Co., Ltd.; COSCO Container Lines Company Limited; Evergreen Line A Joint Service Agreement; Hanjin Shipping Co., Ltd... Maritime Commission (Commission) by China Shipping Container Lines Co., Ltd.; COSCO Container Lines Company...

  16. Endometrial stem cell differentiation into smooth muscle cell: a novel approach for bladder tissue engineering in women.

    Science.gov (United States)

    Shoae-Hassani, Alireza; Sharif, Shiva; Seifalian, Alexander M; Mortazavi-Tabatabaei, Seyed Abdolreza; Rezaie, Sassan; Verdi, Javad

    2013-10-01

    To investigate manufacturing smooth muscle cells (SMCs) for regenerative bladder reconstruction from differentiation of endometrial stem cells (EnSCs), as the recent discovery of EnSCs from the lining of women's uteri, opens up the possibility of using these cells for tissue engineering applications, such as building up natural tissue to repair prolapsed pelvic floors as well as building urinary bladder wall. Human EnSCs that were positive for cluster of differentiation 146 (CD146), CD105 and CD90 were isolated and cultured in Dulbecco's modified Eagle/F12 medium supplemented with myogenic growth factors. The myogenic factors included: transforming growth factor β, platelet-derived growth factor, hepatocyte growth factor and vascular endothelial growth factor. Differentiated SMCs on bioabsorbable polyethylene-glycol and collagen hydrogels were checked for SMC markers by real-time reverse-transcriptase polymerase chain reaction (RT-PCR), western blot (WB) and immunocytochemistry (ICC) analyses. Histology confirmed the growth of SMCs in the hydrogel matrices. The myogenic growth factors decreased the proliferation rate of EnSCs, but they differentiated the human EnSCs into SMCs more efficiently on hydrogel matrices and expressed specific SMC markers including α-smooth muscle actin, desmin, vinculin and calponin in RT-PCR, WB and ICC experiments. The survival rate of cultures on the hydrogel-coated matrices was significantly higher than uncoated cultures. Human EnSCs were successfully differentiated into SMCs, using hydrogels as scaffold. EnSCs may be used for autologous bladder wall regeneration without any immunological complications in women. Currently work is in progress using bioabsorbable nanocomposite materials as EnSC scaffolds for developing urinary bladder wall tissue. © 2013 The Authors. BJU International © 2013 BJU International.

  17. From Off-line to On-line Handwriting Recognition

    NARCIS (Netherlands)

    Lallican, P.; Viard-Gaudin, C.; Knerr, S.

    2004-01-01

    On-line handwriting includes more information on time order of the writing signal and on the dynamics of the writing process than off-line handwriting. Therefore, on-line recognition systems achieve higher recognition rates. This can be concluded from results reported in the literature, and has been

  18. VT Digital Line Graph Miscellaneous Transmission Lines

    Data.gov (United States)

    Vermont Center for Geographic Information — (Link to Metadata) This datalayer is comprised of Miscellaineous Transmission Lines. Digital line graph (DLG) data are digital representations of cartographic...

  19. Efficient algorithm for generating spectra using line-by-line methods

    International Nuclear Information System (INIS)

    Sonnad, V.; Iglesias, C.A.

    2011-01-01

    A method is presented for efficient generation of spectra using line-by-line approaches. The only approximation is replacing the line shape function with an interpolation procedure, which makes the method independent of the line profile functional form. The resulting computational savings for large number of lines is proportional to the number of frequency points in the spectral range. Therefore, for large-scale problems the method can provide speedups of two orders of magnitude or more. A method was presented to generate line-by-line spectra efficiently. The first step was to replace the explicit calculation of the profile by the Newton divided-differences interpolating polynomial. The second step is to accumulate the lines effectively reducing their number to the number of frequency points. The final step is recognizing the resulting expression as a convolution and amenable to FFT methods. The reduction in computational effort for a configuration-to-configuration transition array with large number of lines is proportional to the number of frequency points. The method involves no approximations except for replacing the explicit profile evaluation by interpolation. Specifically, the line accumulation and convolution are exact given the interpolation procedure. Furthermore, the interpolation makes the method independent of the line profile functional form contrary to other schemes using FFT methods to generate line-by-line spectra but relying on the analytic form of the profile Fourier transform. Finally, the method relies on a uniform frequency mesh. For non-uniform frequency meshes, however, the method can be applied by using a suitable temporary uniform mesh and the results interpolated onto the final mesh with little additional cost.

  20. Analysis of some coplanar transmission lines: coplanar coupled lines, coplanar coupled striplines, and coplanar coupled lines with rectangular microshield

    Science.gov (United States)

    Yuan, Naichang; He, Jianguo; Yao, Demiao; Dai, Qin; Lin, Weigan

    1995-06-01

    Two types of coplanar transmission lines, rectangular microshield coplanar coupled lines (RMCCL) and coplanar coupled rectangular microshield lines (CCRML), are proposed for MMIC applications. These are developed from coplanar coupled lines (CCL) and coplanar coupled strip lines (CCS). Analytic formulas are presented for calculating the quasistatic TEM parameters of these coupled lines by means of exact conformal mapping techniques. Numerical results are also presented to illustrate the properties of these coplanar transmission lines.

  1. Interactive Dimensioning of Parametric Models

    KAUST Repository

    Kelly, T.

    2015-06-22

    We propose a solution for the dimensioning of parametric and procedural models. Dimensioning has long been a staple of technical drawings, and we present the first solution for interactive dimensioning: A dimension line positioning system that adapts to the view direction, given behavioral properties. After proposing a set of design principles for interactive dimensioning, we describe our solution consisting of the following major components. First, we describe how an author can specify the desired interactive behavior of a dimension line. Second, we propose a novel algorithm to place dimension lines at interactive speeds. Third, we introduce multiple extensions, including chained dimension lines, controls for different parameter types (e.g. discrete choices, angles), and the use of dimension lines for interactive editing. Our results show the use of dimension lines in an interactive parametric modeling environment for architectural, botanical, and mechanical models.

  2. Clinical outcomes of stapled transanal rectal resection (STARR) for obstructed defecation syndrome (ODS): a single institution experience in South Korea.

    Science.gov (United States)

    Song, Kee Ho; Lee, Du Seok; Shin, Jong Keun; Lee, So Jin; Lee, Jae Bum; Yook, Eui Gon; Lee, Doo Han; Kim, Do Sun

    2011-06-01

    The purpose of this study was to assess both the short- and long-term functional outcomes of stapled transanal rectal resection (STARR) in ODS patients. We performed a retrospective review of data that were collected from January 2005 to October 2008. Between January 2005 to June 2006, 58 patients who underwent STARR were enrolled in this study. Follow-up was scheduled for 3 months and 1 year after surgery with the Cleveland Clinic Florida (CCF) constipation score and satisfaction grade. To evaluate the long-term functional outcome, we interviewed the patients by telephone using questionnaires for the CCF score and satisfaction grade on October 2008. The median follow-up period was 34 months (range, 27-46 months). The mean age and sex ratio were 54 years (range, 19-85 years) and 8:50 (M/F). The mean CCF constipation scores were 17.6 before the surgery, 9.5 at 3 months, 9.6 at 12 months, and 10.3 at the time of the latest interview. The satisfaction grade, which was rated as excellent and good by 63.4% of the patients at the time of the latest interview, was worse than that at 3 months (37.8%). Among the cases of the excellent group (19 cases) at postoperative 3 months, 13 cases (68.4%) were classified as excellent or good at the time of the latest interview. The STARR is a safe and effective surgical procedure for restoring the anatomy and function in ODS patients. Strict selection of patients is needed in enhancing and maintaining the patients' satisfaction after the procedure.

  3. Optimization of line configuration and balancing for flexible machining lines

    Science.gov (United States)

    Liu, Xuemei; Li, Aiping; Chen, Zurui

    2016-05-01

    Line configuration and balancing is to select the type of line and allot a given set of operations as well as machines to a sequence of workstations to realize high-efficiency production. Most of the current researches for machining line configuration and balancing problems are related to dedicated transfer lines with dedicated machine workstations. With growing trends towards great product variety and fluctuations in market demand, dedicated transfer lines are being replaced with flexible machining line composed of identical CNC machines. This paper deals with the line configuration and balancing problem for flexible machining lines. The objective is to assign operations to workstations and find the sequence of execution, specify the number of machines in each workstation while minimizing the line cycle time and total number of machines. This problem is subject to precedence, clustering, accessibility and capacity constraints among the features, operations, setups and workstations. The mathematical model and heuristic algorithm based on feature group strategy and polychromatic sets theory are presented to find an optimal solution. The feature group strategy and polychromatic sets theory are used to establish constraint model. A heuristic operations sequencing and assignment algorithm is given. An industrial case study is carried out, and multiple optimal solutions in different line configurations are obtained. The case studying results show that the solutions with shorter cycle time and higher line balancing rate demonstrate the feasibility and effectiveness of the proposed algorithm. This research proposes a heuristic line configuration and balancing algorithm based on feature group strategy and polychromatic sets theory which is able to provide better solutions while achieving an improvement in computing time.

  4. LINE FUSION GENES: a database of LINE expression in human genes

    Directory of Open Access Journals (Sweden)

    Park Hong-Seog

    2006-06-01

    Full Text Available Abstract Background Long Interspersed Nuclear Elements (LINEs are the most abundant retrotransposons in humans. About 79% of human genes are estimated to contain at least one segment of LINE per transcription unit. Recent studies have shown that LINE elements can affect protein sequences, splicing patterns and expression of human genes. Description We have developed a database, LINE FUSION GENES, for elucidating LINE expression throughout the human gene database. We searched the 28,171 genes listed in the NCBI database for LINE elements and analyzed their structures and expression patterns. The results show that the mRNA sequences of 1,329 genes were affected by LINE expression. The LINE expression types were classified on the basis of LINEs in the 5' UTR, exon or 3' UTR sequences of the mRNAs. Our database provides further information, such as the tissue distribution and chromosomal location of the genes, and the domain structure that is changed by LINE integration. We have linked all the accession numbers to the NCBI data bank to provide mRNA sequences for subsequent users. Conclusion We believe that our work will interest genome scientists and might help them to gain insight into the implications of LINE expression for human evolution and disease. Availability http://www.primate.or.kr/line

  5. Cable line engineering

    International Nuclear Information System (INIS)

    Jang, Hak Sin; Kim, Sin Yeong

    1998-02-01

    This book is about cable line engineering. It is comprised of nine chapters, which deals with summary of cable communication such as way, process of cable communication and optical communication, Line constant of transmission on primary constant, reflection and crosstalk, communication cable line of types like flat cable, coaxial cable and loaded cable, Install of communication line with types and facility of aerial line, construction method of communication line facility, Measurement of communication line, Carrier communication of summary, PCM communication with Introduction, regeneration relay system sampling and quantization and Electric communication service and general information network with mobile communication technique and satellite communication system.

  6. TRREMS procedure (transanal repair of rectocele and rectal mucosectomy with one circular stapler: a prospective multicenter trial

    Directory of Open Access Journals (Sweden)

    José Vinicius Cruz

    2011-03-01

    Full Text Available CONTEXT: Since anorectocele is usually associated with mucosa prolapse and/or rectal intussusceptions, it was developed a stapled surgical technique using one circular stapler. OBJECTIVE: To report the results of Transanal Repair of Rectocele and Rectal Mucosectomy with one Circular Stapler (TRREMS procedure in the treatment of anorectocele with mucosa prolapse in a prospective multicenter trial. METHODS: It was conducted by 14 surgeons and included 75 female patients, mean aged 49.6 years, with symptoms of obstructed defecation due to grade 2 (26.7% and grade 3 (73.3% anorectocele associated with mucosa prolapse and/or rectal intussusception (52.0% and an average validated Wexner constipation score of 16. All patients were evaluated by a proctological examination, cinedefecography, anal manometry and colonic transit time. The TRREMS procedure consists of the manual removal of the rectocele wall with circumferential rectal mucosectomy performed with a circular stapler. The mean follow-up time was 21 months. RESULTS: All patients presented obstructed defecation and they persisted with symptoms despite conservative treatment. The mean operative time was 42 minutes. In 13 (17.3% patients, bleeding from the stapled line required hemostatic suture. Stapling was incomplete in 2 (2.6%. Forty-nine patients (65.3% required 1 hospitalization day, the remainder (34.7% 2 days. Postoperatively, 3 (4.0% patients complained of persistent rectal pain and 7 (9.3% developed stricture on the stapled suture subsequently treated by stricturectomy under anesthesia (n = 1, endoscopic stricturectomy with hot biopsy forceps (n = 3 and digital dilatation (n = 3. Postoperative cinedefecography showed residual grade I anorectoceles in 8 (10.6%. The mean Wexner constipation score decreased significantly from 16 to 4 (0-4: n = 68 (6: n = 6 (7: n = 1 (P<0.0001. CONCLUSION: Current trial results suggest that TRREMS procedure is a safe and effective technique for the treatment

  7. Conventional (CH) vs. stapled hemorrhoidectomy (SH) in surgical treatment of hemorrhoids. Ten years experience.

    Science.gov (United States)

    Manfredelli, Simone; Montalto, Gioacchino; Leonetti, Giovanni; Covotta, Marco; Amatucci, Chiara; Covotta, Alfredo; Forte, Angelo

    2012-01-01

    Interest about hemorrhoids is related to its high incidence and elevated social costs that derive from its treatment. Several comparative studies are reported in Literature to define a standard for ideal treatment of hemorrhoidal disease. Radical surgery is the only therapeutic option in case of III and IV stage haemorrhoids. Hemorrhoids surgical techniques are classified as Open, Closed and Stapled ones. We report our decennial experience on surgical treatment focusing on early, middle and late complications, indications and contraindications, satisfaction level of each surgical procedure for hemorrhoids. Four hundred forty-eight patients have been hospitalized in our department fom 1st January to 31st December 2008. Of these 241 underwent surgery with traditional open or closed technique and 207 with the SH technique according to Longo. This retrospective study includes only patients with symptomatic hemorrhoids at III or IV stage. There were no differences between CH and SH about both pre and post surgery hospitalization and intraoperative length. Pain is the most frequently observed early complication with a statistically significant difference in favour of SH. We obtain good results in CH group using anoderma sparing and perianal anaesthetic infiltration at the end of the surgery. In all cases, pain relief was obtained only with standard analgesic drugs (NSAIDs). We also observed that pain level influences the outcome after surgical treatment. No chronic pain cases were observed in both groups. Bleeding is another relevant early complication in particular after SH: we reported 2 cases of immediate surgical reintenvention and 2 cases treated with blood transfusion. Only in SH group we report also 5 cases of thrombosis of external haemorrhoids and 7 perianal hematoma both solved with medical therapy There were no statistical significant differences between two groups about fever, incontinence to flatus, urinary retention, fecal incontinence, substenosis and anal

  8. Stapled trans-anal rectal resection (STARR) in the surgical treatment of the obstructed defecation syndrome: results of STARR Italian Registry.

    Science.gov (United States)

    Stuto, Angelo; Renzi, Adolfo; Carriero, Alfonso; Gabrielli, Francesco; Gianfreda, Valeria; Villani, Roberto Dino; Pietrantoni, Carmine; Seria, Giovanni; Capomagi, Antonio; Talento, Pasquale

    2011-09-01

    This study was designed to evaluate the safety and efficacy of stapled trans-anal rectal resection (STARR) in the treatment of obstructed defecation syndrome ODS by the analysis of the data collected in the STARR Italian Registry (SIR) with a special emphasis on the analysis of symptoms and quality of life. Collected data included, preoperative tests findings, and the evaluation of symptoms; the latter was obtained by using dedicated tools such as the Obstructed Defecation Syndrome Score (ODS-S), the Severity Symptom Score (SSS), and the Continence Grading Scale (CGS). Data on the quality of life were collected by Patient Assessment of Constipation Quality of Life (PAC-QoL) and the Euro Quality of Life-5 Domains Visual Analogue Scale (EQ-5D VAS). The evaluation of the symptoms and the quality of life was repeated 6 and 12 months after surgery. The SIR had collected data on 2171 patients (1653 females, 76.1%; mean age 56.2 years; range 20-96 years). A significant improvement (P < .0001) was seen between preoperative and 12-month follow-up in all scores: ODS-S (16.7 vs. 5.0), SSS (15.6 vs. 2.6), CGS (2.0 vs. 0.7), PAC-QoL (51.0 vs. 22.1), and EQ-5D VAS (57.5 vs. 85.7). Complications included defecatory urgency (4.5% at 12 months), bleeding (3.6%), perineal sepsis (3.4%), and one case of rectovaginal fistula (0.05%). The analysis of SIR data seems to confirm that STARR is a safe and effective procedure in the treatment of ODS. However, further studies are required to evaluate the long-term stability of results.

  9. An Assessment of the Potential Impact of Fortification of Staples and Condiments on Micronutrient Intake of Young Children and Women of Reproductive Age in Bangladesh

    Directory of Open Access Journals (Sweden)

    Magali Leyvraz

    2016-09-01

    Full Text Available Bangladesh has experienced rapid economic growth and achieved major health improvements in the past decade, but malnutrition rates remain high. A nationally representative study conducted in 2011 assessed the dietary habits of 841 children 24–59 months old, 1428 children 6–14 years old, and 1412 nonpregnant, nonlactating women. The study’s objective was to assess dietary intakes of key micronutrients and the consumption pattern of potentially fortifiable foods, and then to model the potential impact of the fortification of key staple foods. The current intakes of several micronutrients—namely, iron, zinc, folate, vitamin A, and vitamin B12—were found to be insufficient to meet the needs of Bangladesh’s children and women. The fortification of rice with iron and zinc and edible oil with vitamin A has the potential to fill a significant part of the nutrient gap, as these are consumed widely and in significant amounts. Wheat flour and sugar are not as promising food vehicles in the Bangladeshi context, as they were consumed by a smaller portion of the population and in smaller amounts. In conclusion, fortification of rice and oil is recommended to address the large gap in micronutrient intakes.

  10. Midterm performance of a novel restorative pulmonary valved conduit: preclinical results

    NARCIS (Netherlands)

    Soliman, Osama I.; Miyazaki, Yosuke; Abdelghani, Mohammad; Brugmans, Marieke; Witsenburg, Maarten; Onuma, Yoshinobu; Cox, Martijn; Serruys, Patrick W.

    2017-01-01

    Aims: The Xeltis bioabsorbable pulmonary valved conduit (XPV), designed to guide functional restoration of patients' own tissue, is potentially more durable than current pulmonary bioprosthetic valves/valved conduits. The aim of this study was to assess the haemodynamic performance of the novel XPV

  11. Transmission Line Ampacity Improvements of AltaLink Wind Plant Overhead Tie-Lines Using Weather-Based Dynamic Line Rating

    Energy Technology Data Exchange (ETDEWEB)

    Bhattarai, Bishnu P.; Gentle, Jake P.; Hill, Porter; McJunkin, Tim; Myers, Kurt S.; Abbound, Alex; Renwick, Rodger; Hengst, David

    2017-07-01

    Abstract—Overhead transmission lines (TLs) are conventionally given seasonal ratings based on conservative environmental assumptions. Such an approach often results in underutilization of the line ampacity as the worst conditions prevail only for a short period over a year/season. We presents dynamic line rating (DLR) as an enabling smart grid technology that adaptively computes ratings of TLs based on local weather conditions to utilize additional headroom of existing lines. In particular, general line ampacity state solver utilizes measured weather data for computing the real-time thermal rating of the TLs. The performance of the presented method is demonstrated from a field study of DLR technology implementation on four TL segments at AltaLink, Canada. The performance is evaluated and quantified by comparing the existing static and proposed dynamic line ratings, and the potential benefits of DLR for enhanced transmission assets utilization. For the given line segments, the proposed DLR results in real-time ratings above the seasonal static ratings for most of the time; up to 95.1% of the time, with a mean increase of 72% over static rating.

  12. Directed line liquids

    International Nuclear Information System (INIS)

    Kamien, R.D.

    1992-01-01

    This thesis is devoted to the study of ensembles of dense directed lines. These lines are principally to be thought of as polymers, though they also have the morphology of flux lines in high temperature superconductors, strings of colloidal spheres in electrorheological fluids and the world lines of quantum mechanical bosons. The authors discuss how directed polymer melts, string-like formations in electrorheological and ferro-fluids, flux lines in high temperature superconductors and the world lines of quantum mechanical bosons all share similar descriptions. They study a continuous transition in all of these systems, and then study the critical mixing properties of binary mixtures of directed polymers through the renormalization group. They predict the exponents for a directed polymer blend consolute point and a novel two-phase superfluid liquid-gas critical point

  13. Pulmonary suture abscess with false-positive 18F-fluorodeoxyglucose positron emission scan mimicking lung cancer recurrence.

    Science.gov (United States)

    Iwasaki, Teruo; Nakagawa, Katsuhiro; Katsura, Hiroshi; Nakane, Shigeru; Kawahara, Kunimitsu; Fukuda, Haruyuki

    2006-08-01

    We present the case of a 57-year-old woman with pulmonary suture abscess. She had undergone right S3 segmentectomy for early lung adenocarcinoma 7 years before and right breast-conserving surgery for invasive ductal carcinoma 5 months previously, followed by irradiation plus endocrine therapy. Chest radiography and computed tomography revealed an irregular mass (3.5 cm in diameter) between the residual S1 segment and the middle lobe, neighboring the staple line of the segmentectomy. 18F-fluorodeoxyglucose uptake into the mass increased, seen by positron emission scans. Therefore, we could not rule out the possibility of local recurrence of lung cancer and resected it. Pathologically and microbiologically, the mass was a suture abscess arising around the nylon suture of the previous segmentectomy. This lesion was the result of a foreign-body reaction, as confirmed by polarized microscopy. Moreover, titanium staples at the segmentectomy and breast-conserving surgery may also have contributed to this condition.

  14. Hemorroidectomia convencional versus hemorroidopexia mecânica (PPH: estudo retrospectivo de 253 casos Conventional hemorrhoidectomy versus stapled hemorrhoidopexy (PPH: a retrospective study of 253 patients

    Directory of Open Access Journals (Sweden)

    Raphael Marianelli

    2009-03-01

    Full Text Available O objetivo deste estudo foi rever a experiência do serviço de coloproctologia do HSPM-SP no tratamento cirúrgico da doença hemorroidária. Estudou-se retrospectivamente 253 pacientes portadores de hemorroidas submetidos à cirurgia no período de 10/05/2004 a 31/12/2007. Foram estabelecidos dois grupos: Grupo 1 Pacientes operados pela técnica convencional (212; Grupo 2 Pacientes operados pelo PPH (41. Estudou-se, pela revisão de prontuários, as características epidemiológicas, indicações, resultados e complicações de cada grupo. Entre os 253 pacientes analisados, 170 eram mulheres, com média de idade de 50 anos. O tempo operatório médio foi de 52 minutos para o grupo 1, e 31 minutos para o grupo 2 (p=0,0001. O tempo médio de alta ambulatorial foi de 10 e 6 semanas para o grupo 1 e 2, respectivamente (p=0,021. As complicações totalizaram 28 casos no grupo 1, e 3 casos no grupo 2 (p>0,05. Cerca de 13 casos no grupo 1, e 1 caso no grupo 2 necessitaram de reintervenção cirúrgica. Neste serviço a técnica mais utilizada foi a hemorroidectomia convencional. O método do PPH apresentou tempo operatório mais curto, e recuperação pós-operatória mais breve. Houve uma maior tendência a complicações tardias e recidivas com o grupo de hemorroidectomia convencional, porém sem significância estatística.The aim of this study was to review the experience of the Coloproctology Department of HSPM-SP in the treatment of hemorrhoids. We have retrospectively studied 253 patients submitted to the surgical treatment of hemorrhoids between 05/10/ 2004 and 12/31/2007. Patients were distributed in groups: Group 1 Conventional Hemorrhoidectomy (212; Group 2 Stapled Hemorrhoidopexy (41. Epidemiology, indications, results and complications were studied based on registers. From 253 patients studied, 170 were women, with a mean age of 50 years. Mean operating time was 52 minutes (25 -120 in group 1 and 31 minutes (20 - 65 in group 2 (p=0

  15. Stapled side-to-side anastomosis might be better than handsewn end-to-end anastomosis in ileocolic resection for Crohn's disease: a meta-analysis.

    Science.gov (United States)

    He, Xiaosheng; Chen, Zexian; Huang, Juanni; Lian, Lei; Rouniyar, Santosh; Wu, Xiaojian; Lan, Ping

    2014-07-01

    Ileocolic anastomosis is an essential step in the treatment to restore continuity of the gastrointestinal tract following ileocolic resection in patients with Crohn's disease (CD). However, the association between anastomotic type and surgical outcome is controversial. The aim of this meta-analysis is to compare surgical outcomes between stapled side-to-side anastomosis (SSSA) and handsewn end-to-end anastomosis (HEEA) after ileocolic resection in patients with CD. Studies comparing SSSA with HEEA after ileocolic resection in patients with CD were identified in PubMed and EMBASE. Outcomes such as complication, recurrence, and re-operation were evaluated. Eight studies (three randomized controlled trials, one prospective non-randomized trial, and four non-randomized retrospective trials) comparing SSSA (396 cases) and HEEA (425 cases) were included. As compared with HEEA, SSSA was superior in terms of overall postoperative complications [odds ratio (OR), 0.54; 95 % confidence interval (CI) 0.32-0.93], anastomotic leak (OR 0.45; 95 % CI 0.20-1.00), recurrence (OR 0.20; 95 % CI 0.07-0.55), and re-operation for recurrence (OR 0.18; 95 % CI 0.07-0.45). Postoperative hospital stay, mortality, and complications other than anastomotic leak were comparable. Based on the results of our meta-analysis, SSSA would appear to be the preferred procedure after ileocolic resection for CD, with reduced overall postoperative complications, especially anastomotic leak, and a decreased recurrence and re-operation rate.

  16. MICROLENSING OF QUASAR BROAD EMISSION LINES: CONSTRAINTS ON BROAD LINE REGION SIZE

    Energy Technology Data Exchange (ETDEWEB)

    Guerras, E.; Mediavilla, E. [Instituto de Astrofisica de Canarias, Via Lactea S/N, La Laguna E-38200, Tenerife (Spain); Jimenez-Vicente, J. [Departamento de Fisica Teorica y del Cosmos, Universidad de Granada, Campus de Fuentenueva, E-18071 Granada (Spain); Kochanek, C. S. [Department of Astronomy and the Center for Cosmology and Astroparticle Physics, The Ohio State University, 4055 McPherson Lab, 140 West 18th Avenue, Columbus, OH 43221 (United States); Munoz, J. A. [Departamento de Astronomia y Astrofisica, Universidad de Valencia, E-46100 Burjassot, Valencia (Spain); Falco, E. [Center for Astrophysics, 60 Garden Street, Cambridge, MA 02138 (United States); Motta, V. [Departamento de Fisica y Astronomia, Universidad de Valparaiso, Avda. Gran Bretana 1111, Valparaiso (Chile)

    2013-02-20

    We measure the differential microlensing of the broad emission lines between 18 quasar image pairs in 16 gravitational lenses. We find that the broad emission lines are in general weakly microlensed. The results show, at a modest level of confidence (1.8{sigma}), that high ionization lines such as C IV are more strongly microlensed than low ionization lines such as H{beta}, indicating that the high ionization line emission regions are more compact. If we statistically model the distribution of microlensing magnifications, we obtain estimates for the broad line region size of r{sub s} = 24{sup +22} {sub -15} and r{sub s} = 55{sup +150} {sub -35} lt-day (90% confidence) for the high and low ionization lines, respectively. When the samples are divided into higher and lower luminosity quasars, we find that the line emission regions of more luminous quasars are larger, with a slope consistent with the expected scaling from photoionization models. Our estimates also agree well with the results from local reveberation mapping studies.

  17. Lining seam elimination algorithm and surface crack detection in concrete tunnel lining

    Science.gov (United States)

    Qu, Zhong; Bai, Ling; An, Shi-Quan; Ju, Fang-Rong; Liu, Ling

    2016-11-01

    Due to the particularity of the surface of concrete tunnel lining and the diversity of detection environments such as uneven illumination, smudges, localized rock falls, water leakage, and the inherent seams of the lining structure, existing crack detection algorithms cannot detect real cracks accurately. This paper proposed an algorithm that combines lining seam elimination with the improved percolation detection algorithm based on grid cell analysis for surface crack detection in concrete tunnel lining. First, check the characteristics of pixels within the overlapping grid to remove the background noise and generate the percolation seed map (PSM). Second, cracks are detected based on the PSM by the accelerated percolation algorithm so that the fracture unit areas can be scanned and connected. Finally, the real surface cracks in concrete tunnel lining can be obtained by removing the lining seam and performing percolation denoising. Experimental results show that the proposed algorithm can accurately, quickly, and effectively detect the real surface cracks. Furthermore, it can fill the gap in the existing concrete tunnel lining surface crack detection by removing the lining seam.

  18. High Line

    DEFF Research Database (Denmark)

    Kiib, Hans

    2015-01-01

    At just over 10 meters above street level, the High Line extends three kilometers through three districts of Southwestern Manhattan in New York. It consists of simple steel construction, and previously served as an elevated rail line connection between Penn Station on 34th Street and the many....... The High Line project has been carried out as part of an open conversion strategy. The result is a remarkable urban architectural project, which works as a catalyst for the urban development of Western Manhattan. The greater project includes the restoration and reuse of many old industrial buildings...

  19. Assessment of the RIVET fixation system for cranioplasty using the pull-out technique.

    Science.gov (United States)

    Sakamoto, Yoshiaki; Minabe, Toshiharu; Kato, Tatsuya; Kishi, Kazuo

    2015-03-01

    Cranioplasty using custom-made hydroxyapatite (HAP) ceramic implants is a common procedure to repair skull defects. However, commercially available titanium screws are only minimally stabilized due to characteristic brittleness. We developed the RIVET technique which involves fixing a bioabsorbable plate atop a HAP block using bioabsorbable screws extending beyond both layers, and evaluated fixation strength using the pull-out test and microtomography. Three experimental conditions were compared: a non-RIVET group, RIVET group, and dry skull control group. Pull-out strength significantly differed across groups (non-RIVET group, 1.33 ± 1.21 kgf; RIVET group, 4.46 ± 0.84 kgf; and control group, 6.99 ± 1.14 kgf, P uses commercially available absorbable plate and screws, and thus can be used widely in clinical applications involving HAP blocks with different porosities and thicknesses. Copyright © 2014 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  20. Antibiotic-containing hyaluronic acid gel as an antibacterial carrier: Usefulness of sponge and film-formed HA gel in deep infection.

    Science.gov (United States)

    Matsuno, Hiroaki; Yudoh, Kazuo; Hashimoto, Masamichi; Himeda, Yasukazu; Miyoshi, Teruzo; Yoshida, Kaoru; Kano, Syogo

    2006-03-01

    We have developed a novel bioabsorbable antibacterial carrier using hyaluronic acid (HA) gel for prevention and treatment of orthopedic infections. In this study, we investigated the in vivo antibacterial effects of two forms of this new material, an HA gel sponge and an HA gel film. A titanium cylinder was inserted into the intramedullary cavity of each rabbit femur, along with an HA gel sponge or HA gel film containing antibiotics. The HA gel sponge contained gentamycin, vancomycin, tobramycin, or minomycin. The HA gel film contained gentamycin or vancomycin. After 0, 7, and 14 days, the rabbit bone marrow was collected, and the antibacterial activity of the HA gel was determined by agar diffusion test. As a control, we used Septocoll, a commercially available antibacterial carrier. Both the HA gel sponge and HA gel film exhibited antibacterial activity. The present results indicate that HA gel containing antibiotics is a clinically useful bioabsorbable antibacterial carrier. Copyright 2006 Orthopaedic Research Society.

  1. An ultrafast line-by-line algorithm for calculating spectral transmittance and radiance

    International Nuclear Information System (INIS)

    Tan, X.

    2013-01-01

    An ultrafast line-by-line algorithm for calculating spectral transmittance and radiance of gases is presented. The algorithm is based on fast convolution of the Voigt line profile using Fourier transform and a binning technique. The algorithm breaks a radiative transfer calculation into two steps: a one-time pre-computation step in which a set of pressure independent coefficients are computed using the spectral line information; a normal calculation step in which the Fourier transform coefficients of the optical depth are calculated using the line of sight information and the coefficients pre-computed in the first step, the optical depth is then calculated using an inverse Fourier transform and the spectral transmittance and radiance are calculated. The algorithm is significantly faster than line-by-line algorithms that do not employ special speedup techniques by a factor of 10 3 –10 6 . A case study of the 2.7 μm band of H 2 O vapor is presented. -- Highlights: •An ultrafast line-by-line model based on FFT and a binning technique is presented. •Computationally expensive calculations are factored out into a pre-computation step. •It is 10 3 –10 8 times faster than LBL algorithms that do not employ speedup techniques. •Good agreement with experimental data for the 2.7 μm band of H 2 O

  2. Covariant electromagnetic field lines

    Science.gov (United States)

    Hadad, Y.; Cohen, E.; Kaminer, I.; Elitzur, A. C.

    2017-08-01

    Faraday introduced electric field lines as a powerful tool for understanding the electric force, and these field lines are still used today in classrooms and textbooks teaching the basics of electromagnetism within the electrostatic limit. However, despite attempts at generalizing this concept beyond the electrostatic limit, such a fully relativistic field line theory still appears to be missing. In this work, we propose such a theory and define covariant electromagnetic field lines that naturally extend electric field lines to relativistic systems and general electromagnetic fields. We derive a closed-form formula for the field lines curvature in the vicinity of a charge, and show that it is related to the world line of the charge. This demonstrates how the kinematics of a charge can be derived from the geometry of the electromagnetic field lines. Such a theory may also provide new tools in modeling and analyzing electromagnetic phenomena, and may entail new insights regarding long-standing problems such as radiation-reaction and self-force. In particular, the electromagnetic field lines curvature has the attractive property of being non-singular everywhere, thus eliminating all self-field singularities without using renormalization techniques.

  3. A pragmatic multicentre randomised controlled trial comparing stapled haemorrhoidopexy with traditional excisional surgery for haemorrhoidal disease: the eTHoS study.

    Science.gov (United States)

    Watson, Angus Jm; Cook, Jonathan; Hudson, Jemma; Kilonzo, Mary; Wood, Jessica; Bruhn, Hanne; Brown, Steven; Buckley, Brian; Curran, Finlay; Jayne, David; Loudon, Malcolm; Rajagopal, Ramesh; McDonald, Alison; Norrie, John

    2017-11-01

    Haemorrhoids are a benign anorectal condition and are highly prevalent in the UK population. Treatments involve clinic-based procedures and surgery. The surgical procedures available include stapled haemorrhoidopexy (SH) and traditional haemorrhoidectomy (TH), and over 25,000 operations are performed for haemorrhoids annually in the UK. The disease is therefore important both to patients and to health service commissioners. Debate remains as to which of these surgical procedures is the most clinically effective and cost-effective. The aim of this study was to compare the clinical effectiveness and cost-effectiveness of SH with that of TH. A large, open two-arm parallel-group pragmatic multicentre randomised controlled trial involving 32 UK hospitals and a within-trial cost-benefit analysis. A discrete choice experiment was conducted to estimate benefits (willingness to pay). Patients with grades II-IV haemorrhoids who had not previously undergone SH or TH were included in the study. Participants were randomised to receive either SH or TH. Randomisation was minimised at 1 : 1, in accordance with baseline EuroQol-5 Dimensions, three-level version (EQ-5D-3L) score, haemorrhoid grade, sex and centre, via an automated system. The primary outcome was area under the quality-of-life curve measured using the EQ-5D-3L descriptive system over 24 months, and the primary economic outcome was the incremental cost-effectiveness ratio. Secondary outcomes included disease-specific quality of life, recurrence, complications, further interventions and costs. Between January 2011 and August 2014, 777 patients were randomised (389 to receive SH and 388 to receive TH). There were 774 participants included in the analysis as a result of one post-randomisation exclusion in the SH arm and two in the TH arm. SH was less painful than TH in the short term. Surgical complications were similar in both arms. EQ-5D-3L score was higher for the SH arm in the first 6 weeks after surgery, but

  4. The End of the Lines for OX 169: No Binary Broad-Line Region

    Science.gov (United States)

    Halpern, J. P.; Eracleous, M.

    2000-03-01

    We show that unusual Balmer emission-line profiles of the quasar OX 169, frequently described as either self-absorbed or double peaked, are actually neither. The effect is an illusion resulting from two coincidences. First, the forbidden lines are quite strong and broad. Consequently, the [N II] λ6583 line and the associated narrow-line component of Hα present the appearance of twin Hα peaks. Second, the redshift of 0.2110 brings Hβ into coincidence with Na I D at zero redshift, and ISM absorption in Na I D divides the Hβ emission line. In spectra obtained over the past decade, we see no substantial change in the character of the line profiles and no indication of intrinsic double-peaked structure. The Hγ, Mg II, and Lyα emission lines are single peaked, and all of the emission-line redshifts are consistent once they are correctly attributed to their permitted and forbidden-line identifications. A systematic shift of up to 700 km s-1 between broad and narrow lines is seen, but such differences are common and could be due to gravitational and transverse redshift in a low-inclination disk. Stockton & Farnham had called attention to an apparent tidal tail in the host galaxy of OX 169 and speculated that a recent merger had supplied the nucleus with a coalescing pair of black holes that was now revealing its existence in the form of two physically distinct broad-line regions. Although there is no longer any evidence for two broad emission-line regions in OX 169, binary black holes should form frequently in galaxy mergers, and it is still worthwhile to monitor the radial velocities of emission lines that could supply evidence of their existence in certain objects.

  5. Nasca Lines, Peru

    Science.gov (United States)

    2001-01-01

    The Nasca Lines are located in the Pampa region of Peru, the desolate plain of the Peruvian coast 400 km south of Lima. The Lines were first spotted when commercial airlines began flying across the Peruvian desert in the 1920's. Passengers reported seeing 'primitive landing strips' on the ground below. The Lines were made by removing the iron-oxide coated pebbles which cover the surface of the desert. When the gravel is removed, they contrast with the light color underneath. In this way the lines were drawn as furrows of a lighter color. On the pampa, south of the Nasca Lines, archaeologists have now uncovered the lost city of the line-builders, Cahuachi. It was built nearly two thousand years ago and was mysteriously abandoned 500 years later. This ASTER sub-image covers an area of 14 x 18 km, was acquired on December 22, 2000, and is located at 14.7 degrees south latitude and 75.1 degrees west longitude. The U.S. science team is located at NASA's Jet Propulsion Laboratory, Pasadena, Calif. The Terra mission is part of NASA's Science Mission Directorate.

  6. Bioresorbable Polymer-Coated Orsiro Versus Durable Polymer-Coated Resolute Onyx Stents (BIONYX) : Rationale and design of the randomized TWENTE IV multicenter trial

    NARCIS (Netherlands)

    van der Heijden, Liefke C.; Kok, Marlies M.; Zocca, Paolo; Jessurun, Gillian A.J.; Schotborgh, Carl E.; Roguin, Ariel; Benit, Edouard; Aminian, Adel; Danse, Peter W.; Löwik, Marije M.; Linssen, Gerard C.M.; van der Palen, Job; Doggen, Carine J.M.; von Birgelen, Clemens

    2018-01-01

    Aim: The aim was to compare in a noninferiority trial the efficacy and safety of 2 contemporary drug-eluting stents (DESs): a novel, durable polymer-coated stent versus an established bioabsorbable polymer-coated stent. Methods and results: The BIONYX trial (ClinicalTrials.gov-no.NCT02508714) is an

  7. The "stamp method" : a new treatment for perforated peptic ulcer?

    NARCIS (Netherlands)

    Bertleff, M.J.O.E.; Liem, RSB; Robinson, PH; Bonjer, HJ; Lange, J. F.; Bartels, H.; van der Werf, J.F.A.

    Background: The aim of this study was to develop a simple method for closure of a perforated peptic ulcer, making it more accessible for laparoscopic surgery. Methods: An experimental pilot study was performed using five male Wistar rats. The perforation was closed by a bioabsorbable patch made of

  8. An OCD perspective of line edge and line width roughness metrology

    Science.gov (United States)

    Bonam, Ravi; Muthinti, Raja; Breton, Mary; Liu, Chi-Chun; Sieg, Stuart; Seshadri, Indira; Saulnier, Nicole; Shearer, Jeffrey; Patlolla, Raghuveer; Huang, Huai

    2017-03-01

    Metrology of nanoscale patterns poses multiple challenges that range from measurement noise, metrology errors, probe size etc. Optical Metrology has gained a lot of significance in the semiconductor industry due to its fast turn around and reliable accuracy, particularly to monitor in-line process variations. Apart from monitoring critical dimension, thickness of films, there are multiple parameters that can be extracted from Optical Metrology models3. Sidewall angles, material compositions etc., can also be modeled to acceptable accuracy. Line edge and Line Width roughness are much sought of metrology following critical dimension and its uniformity, although there has not been much development in them with optical metrology. Scanning Electron Microscopy is still used as a standard metrology technique for assessment of Line Edge and Line Width roughness. In this work we present an assessment of Optical Metrology and its ability to model roughness from a set of structures with intentional jogs to simulate both Line edge and Line width roughness at multiple amplitudes and frequencies. We also present multiple models to represent roughness and extract relevant parameters from Optical metrology. Another critical aspect of optical metrology setup is correlation of measurement to a complementary technique to calibrate models. In this work, we also present comparison of roughness parameters extracted and measured with variation of image processing conditions on a commercially available CD-SEM tool.

  9. Modification of the U-line of the RHIC injection line

    International Nuclear Information System (INIS)

    Xu, Jianming.

    1991-09-01

    The parameters of the U-line of the RHIC injection line with low β waist are described. In that lattice, the location of SA is not dispersion free and 14 quadrupoles are needed. This line has been modified to move SA to a dispersion free region (after the 8-degree bend), the length and maximum gradient of quadrupoles have been adjusted to fit the existing quadrupole parameters and the number of quadrupoles is reduced to 12. 2 refs., 3 tabs

  10. A blended approach to analyze staple and high-value crops using remote sensing with radiative transfer and crop models.

    Science.gov (United States)

    Davitt, A. W. D.; Winter, J.; McDonald, K. C.; Escobar, V. M.; Steiner, N.

    2017-12-01

    The monitoring of staple and high-value crops is important for maintaining food security. The recent launch of numerous remote sensing satellites has created the ability to monitor vast amounts of crop lands, continuously and in a timely manner. This monitoring provides users with a wealth of information on various crop types over different regions of the world. However, a challenge still remains on how to best quantify and interpret the crop and surface characteristics that are measured by visible, near-infrared, and active and passive microwave radar. Currently, two NASA funded projects are examining the ability to monitor different types of crops in California with different remote sensing platforms. The goal of both projects is to develop a cost-effective monitoring tool for use by vineyard and crop managers. The first project is designed to examine the capability to monitor vineyard water management and soil moisture in Sonoma County using Soil Moisture Active Passive (SMAP), Sentinel-1A and -2, and Landsat-8. The combined mission products create thorough and robust measurements of surface and vineyard characteristics that can potentially improve the ability to monitor vineyard health. Incorporating the Michigan Microwave Canopy Scattering (MIMICS), a radiative transfer model, enables us to better understand surface and vineyard features that influence radar measurements from Sentinel-1A. The second project is a blended approach to analyze corn, rice, and wheat growth using Sentinel-1A products with Decision Support System for Agrotechnology Transfer (DSSAT) and MIMICS models. This project aims to characterize the crop structures that influence Sentinel-1A radar measurements. Preliminary results have revealed the corn, rice, and wheat structures that influence radar measurements during a growing season. The potential of this monitoring tool can be used for maintaining food security. This includes supporting sustainable irrigation practices, identifying crop

  11. Difference in membrane repair capacity between cancer cell lines and a normal cell line

    DEFF Research Database (Denmark)

    Frandsen, Stine Krog; McNeil, Anna K.; Novak, Ivana

    2016-01-01

    repair was investigated by disrupting the plasma membrane using laser followed by monitoring fluorescent dye entry over time in seven cancer cell lines, an immortalized cell line, and a normal primary cell line. The kinetics of repair in living cells can be directly recorded using this technique...... cancer cell lines (p immortalized cell line (p

  12. Committing Canadian sociology: developing a Canadian sociology and a sociology of Canada.

    Science.gov (United States)

    Matthews, Ralph

    2014-05-01

    This paper is a slightly revised version of the author's "Outstanding Career Award Lecture" presented at the Annual Meeting of the Canadian Sociological Association in Victoria, British Columbia on June 6, 2013. The paper distinguishes between Canadian Sociology and the Sociology of Canada. The former involves the explanatory stance that one takes to understanding Canada. The latter addresses the significant social dimensions that underlie Canadian social organization, culture, and behavior. I make a case for a Canadian Sociology that focuses on the unique features of Canadian society rather than adopting a comparative perspective. I also argue that there is a continuing need within the Sociology of Canada to address the issues of staples development. However, I argue that "new" staples analysis must have a directional change from that of the past, in that social processes now largely determine the pattern of staples development. Moreover, new staples analysis must include issues that were never part of earlier staples analysis, such as issues of environmental impacts and of staples depletion under conditions, such as climate change. The paper concludes by analyzing four factors that provide the dominant social contexts for analyzing modern staples development: (1) the rise of neoliberal government, (2) the implementation of globalization and its social consequences, (3) the assumption of aboriginal rights and entitlement, and (4) the rise of environmentalism. These factors were generally not considered in earlier staples approaches. They are critical to understanding the role of staples development and its impact on Canada in the present time.

  13. Microwave absorption property of the diatomite coated by Fe-CoNiP films

    International Nuclear Information System (INIS)

    Yan, Zhenqiang; Cai, Jun; Xu, Yonggang; Zhang, Deyuan

    2015-01-01

    Highlights: • The bio-absorbent coated Fe-CoNiP was fabricated by electroless and CVD. • The EM parameters were enlarged as Fe coated on the diatomite. • The coating CIPs play a key role in the enhancement mechanism. • The Fe-CoNiP diatomite had a better absorbing and shielding properties. - Abstract: A bio-absorbent of Fe-CoNiP coated on the diatomite was fabricated by way of electroless plating of CoNiP and subsequent chemical vapor deposition of Fe. The surface morphology and composition of the above-mentioned diatomite particles at different stage were characterized with the scanning electron microscopy and the energy spectrum analysis respectively, and the results showed that the diatomite was successfully coated with CoNoP and Fe (carbony iron). The complex permittivity and permeability of composites filled with the bio-absorbent and paraffin was measured in frequency range of 2–18 GHz, and then the microwave reflection loss (RL) and the shielding effectiveness (SE) were calculated. The results showed that the permittivity and the permeability were both enlarged as Fe films were coated onto the CoNiP-coated diatomite, which was attributed to the excellent electromagnetic property of carbonyl irons. The composites made with the Fe-CoNiP diatomite had a better absorbing property (minimum RL −11.0 dB) as well as the shielding property (maximum SE 5.6 dB) at thickness 2 mm. It indicated the absorption property was mainly due to the attenuation on the microwave, and the Fe-CoNiP diatomite could be an effective absorbent with low-density

  14. Microwave absorption property of the diatomite coated by Fe-CoNiP films

    Energy Technology Data Exchange (ETDEWEB)

    Yan, Zhenqiang; Cai, Jun; Xu, Yonggang, E-mail: xuyonggang221@163.com; Zhang, Deyuan

    2015-08-15

    Highlights: • The bio-absorbent coated Fe-CoNiP was fabricated by electroless and CVD. • The EM parameters were enlarged as Fe coated on the diatomite. • The coating CIPs play a key role in the enhancement mechanism. • The Fe-CoNiP diatomite had a better absorbing and shielding properties. - Abstract: A bio-absorbent of Fe-CoNiP coated on the diatomite was fabricated by way of electroless plating of CoNiP and subsequent chemical vapor deposition of Fe. The surface morphology and composition of the above-mentioned diatomite particles at different stage were characterized with the scanning electron microscopy and the energy spectrum analysis respectively, and the results showed that the diatomite was successfully coated with CoNoP and Fe (carbony iron). The complex permittivity and permeability of composites filled with the bio-absorbent and paraffin was measured in frequency range of 2–18 GHz, and then the microwave reflection loss (RL) and the shielding effectiveness (SE) were calculated. The results showed that the permittivity and the permeability were both enlarged as Fe films were coated onto the CoNiP-coated diatomite, which was attributed to the excellent electromagnetic property of carbonyl irons. The composites made with the Fe-CoNiP diatomite had a better absorbing property (minimum RL −11.0 dB) as well as the shielding property (maximum SE 5.6 dB) at thickness 2 mm. It indicated the absorption property was mainly due to the attenuation on the microwave, and the Fe-CoNiP diatomite could be an effective absorbent with low-density.

  15. What matters after sleeve gastrectomy: patient characteristics or surgical technique?

    Science.gov (United States)

    Dhar, Vikrom K; Hanseman, Dennis J; Watkins, Brad M; Paquette, Ian M; Shah, Shimul A; Thompson, Jonathan R

    2018-03-01

    The impact of operative technique on outcomes in laparoscopic sleeve gastrectomy has been explored previously; however, the relative importance of patient characteristics remains unknown. Our aim was to characterize national variability in operative technique for laparoscopic sleeve gastrectomy and determine whether patient-specific factors are more critical to predicting outcomes. We queried the database of the Metabolic and Bariatric Surgery Accreditation and Quality Improvement Program for laparoscopic sleeve gastrostomies performed in 2015 (n = 88,845). Logistic regression models were used to determine predictors of postoperative outcomes. In 2015, >460 variations of laparoscopic sleeve gastrectomy were performed based on combinations of bougie size, distance from the pylorus, use of staple line reinforcement, and oversewing of the staple line. Despite such substantial variability, technique variants were not predictive of outcomes, including perioperative morbidity, leak, or bleeding (all P ≥ .05). Instead, preoperative patient characteristics were found to be more predictive of these outcomes after laparoscopic sleeve gastrectomy. Only history of gastroesophageal disease (odds ratio 1.44, 95% confidence interval 1.08-1.91, P < .01) was associated with leak. Considerable variability exists in technique among surgeons nationally, but patient characteristics are more predictive of adverse outcomes after laparoscopic sleeve gastrectomy. Bundled payments and reimbursement policies should account for patient-specific factors in addition to current accreditation and volume thresholds when deciding risk-adjustment strategies. Copyright © 2018 Elsevier Inc. All rights reserved.

  16. Finger on the Pulse: Pumping Iron into Chickpea.

    Science.gov (United States)

    Tan, Grace Z H; Das Bhowmik, Sudipta S; Hoang, Thi M L; Karbaschi, Mohammad R; Johnson, Alexander A T; Williams, Brett; Mundree, Sagadevan G

    2017-01-01

    Iron deficiency is a major problem in both developing and developed countries, and much of this can be attributed to insufficient dietary intake. Over the past decades several measures, such as supplementation and food fortification, have helped to alleviate this problem. However, their associated costs limit their accessibility and effectiveness, particularly amongst the financially constrained. A more affordable and sustainable option that can be implemented alongside existing measures is biofortification. To date, much work has been invested into staples like cereals and root crops-this has culminated in the successful generation of high iron-accumulating lines in rice and pearl millet. More recently, pulses have gained attention as targets for biofortification. Being secondary staples rich in protein, they are a nutritional complement to the traditional starchy staples. Despite the relative youth of this interest, considerable advances have already been made concerning the biofortification of pulses. Several studies have been conducted in bean, chickpea, lentil, and pea to assess existing germplasm for high iron-accumulating traits. However, little is known about the molecular workings behind these traits, particularly in a leguminous context, and biofortification via genetic modification (GM) remains to be attempted. This review examines the current state of the iron biofortification in pulses, particularly chickpea. The challenges concerning biofortification in pulses are also discussed. Specifically, the potential application of transgenic technology is explored, with focus on the genes that have been successfully used in biofortification efforts in rice.

  17. Finger on the Pulse: Pumping Iron into Chickpea

    Directory of Open Access Journals (Sweden)

    Grace Z. H. Tan

    2017-10-01

    Full Text Available Iron deficiency is a major problem in both developing and developed countries, and much of this can be attributed to insufficient dietary intake. Over the past decades several measures, such as supplementation and food fortification, have helped to alleviate this problem. However, their associated costs limit their accessibility and effectiveness, particularly amongst the financially constrained. A more affordable and sustainable option that can be implemented alongside existing measures is biofortification. To date, much work has been invested into staples like cereals and root crops—this has culminated in the successful generation of high iron-accumulating lines in rice and pearl millet. More recently, pulses have gained attention as targets for biofortification. Being secondary staples rich in protein, they are a nutritional complement to the traditional starchy staples. Despite the relative youth of this interest, considerable advances have already been made concerning the biofortification of pulses. Several studies have been conducted in bean, chickpea, lentil, and pea to assess existing germplasm for high iron-accumulating traits. However, little is known about the molecular workings behind these traits, particularly in a leguminous context, and biofortification via genetic modification (GM remains to be attempted. This review examines the current state of the iron biofortification in pulses, particularly chickpea. The challenges concerning biofortification in pulses are also discussed. Specifically, the potential application of transgenic technology is explored, with focus on the genes that have been successfully used in biofortification efforts in rice.

  18. Coatings and Biodegradable and Bioabsorbable Films

    Science.gov (United States)

    2006-09-01

    K.A., "Novel Method for Characterization of Poly(D,L-lactide) Degradation Based on Dielectric Spectroscopy ," Polymers for Biomedical Applications ...consumption of Temperature (°C) hydroxyl groups upon cross-linking with HDI. The Figl2. Positron annihilation assessment hydroxyl groups are known to form...higher Tg, the larger none-equilibrium 0 1.26 A 0 volume is accumulated upon cooling. Probing free- A volume with positron life time spectroscopy 1.25

  19. Computational micromechanics of bioabsorbable magnesium stents.

    Science.gov (United States)

    Grogan, J A; Leen, S B; McHugh, P E

    2014-06-01

    Magnesium alloys are a promising candidate material for an emerging generation of absorbable metal stents. Due to its hexagonal-close-packed lattice structure and tendency to undergo twinning, the deformation behaviour of magnesium is quite different to that of conventional stent materials, such as stainless steel 316L and cobalt chromium L605. In particular, magnesium exhibits asymmetric plastic behaviour (i.e. different yield behaviours in tension and compression) and has lower ductility than these conventional alloys. In the on-going development of absorbable metal stents it is important to assess how the unique behaviour of magnesium affects device performance. The mechanical behaviour of magnesium stent struts is investigated in this study using computational micromechanics, based on finite element analysis and crystal plasticity theory. The plastic deformation in tension and bending of textured and non-textured magnesium stent struts with different numbers of grains through the strut dimension is investigated. It is predicted that, unlike 316L and L605, the failure risk and load bearing capacity of magnesium stent struts during expansion is not strongly affected by the number of grains across the strut dimensions; however texturing, which may be introduced and controlled in the manufacturing process, is predicted to have a significant influence on these measures of strut performance. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. Coatings and Biodegradable and Bioabsorbable Films

    National Research Council Canada - National Science Library

    Thames, Shelby F; Rawlins, James W

    2006-01-01

    .... Specifically focusing on the plasticizing effects of vegetable oil macromonomers as incorporated into emulsion polymers for efficient almost zero VOC film formation and the additional benefit of auto...

  1. Stapled side-to-side anastomosis might be benefit in intestinal resection for Crohn's disease: A systematic review and network meta-analysis.

    Science.gov (United States)

    Feng, Jin-Shan; Li, Jin-Yu; Yang, Zheng; Chen, Xiu-Yan; Mo, Jia-Jie; Li, Shang-Hai

    2018-04-01

    Intestinal anastomosis is an essential step in the intestinal resection in patients with Crohn's disease (CD). Anastomotic configuration such as handsewn end-to-end anastomosis (HEEA), stapled side-to-side anastomosis (SSSA) and so on may be a predictor of prognosis for postoperative CD patients. However, the association between anastomotic types and surgical outcomes are controversial. The aim of this review is to identify the optimal anastomosis for intestinal resection in patients with CD. Clinical trials comparing anastomosis after intestinal resection in patients with CD were searched in the database of MEDLINE, EMBASE, and the Cochrane Library. Outcomes such as postoperative hospital stay, complications, mortality, recurrence, and reoperation were evaluated. Pairwise treatment effects were estimated through a random-effects network meta-analysis based on the frequency framework by using the STATA software and reported as the estimated summary effect for each comparison between the 2 treatments in the network with a 95% credible interval. A total of 1113 patients in 11 trials were included. In pair-wise comparisons between groups, for overall postoperative complications, SSSA showed a more probability of superiority to HEEA; for complications other than anastomotic leak, anastomotic leak, wound infection, postoperative hospital stay and mortality, there were no significant difference between groups; for clinical recurrence, SSSA showed a more probability of superiority to HEEA; for reoperation, SSSA showed a more probability of superiority to HEEA. The number of eligible randomized controlled trails (RCTs) was small, and more than half of the included trials were retrospective studies; selection bias may lead to a less power in this assessment; follow-up time between different groups was different, which may possibly have affected the interpretation of the analysis of long-term outcome. By comprehensive analyzing all the postoperative outcomes, SSSA appeared

  2. Purity, adulteration and price of drugs bought on-line versus off-line in the Netherlands.

    Science.gov (United States)

    van der Gouwe, Daan; Brunt, Tibor M; van Laar, Margriet; van der Pol, Peggy

    2017-04-01

    On-line drug markets flourish and consumers have high expectations of on-line quality and drug value. The aim of this study was to (i) describe on-line drug purchases and (ii) compare on-line with off-line purchased drugs regarding purity, adulteration and price. Comparison of laboratory analyses of 32 663 drug consumer samples (stimulants and hallucinogens) purchased between January 2013 and January 2016, 928 of which were bought on-line. The Netherlands. Primary outcome measures were (i) the percentage of samples purchased on-line and (ii) the chemical purity of powders (or dosage per tablet); adulteration; and the price per gram, blotter or tablet of drugs bought on-line compared with drugs bought off-line. The proportion of drug samples purchased on-line increased from 1.4% in 2013 to 4.1% in 2015. The frequency varied widely, from a maximum of 6% for controlled, traditional substances [ecstasy tablets, 3,4-methylenedioxy-methamphetamine (MDMA) powder, amphetamine powder, cocaine powder, 4-bromo-2,5-dimethoxyphenethylamine (2C-B) and lysergic acid diethylamide (LSD)] to more than a third for new psychoactive substances (NPS) [4-fluoroamphetamine (4-FA), 5/6-(2-aminopropyl)benzofuran (5/6-APB) and methoxetamine (MXE)]. There were no large differences in drug purity, yet small but statistically significant differences were found for 4-FA (on-line 59% versus off-line 52% purity for 4-FA on average, P = 0.001), MDMA powders (45 versus 61% purity for MDMA, P = 0.02), 2C-B tablets (21 versus 10 mg 2C-B/tablet dosage, P = 0.49) and ecstasy tablets (131 versus 121 mg MDMA/tablet dosage, P = 0.05). The proportion of adulterated samples purchased on-line and off-line did not differ, except for 4-FA powder, being less adulterated on-line (χ 2  = 8.3; P < 0.02). Drug prices were mainly higher on-line, ranging for various drugs from 10 to 23% higher than that of drugs purchased off-line (six of 10 substances: P < 0.05). Dutch drug users increasingly

  3. Crossing the LINE toward genomic instability: LINE-1 retrotransposition in cancer

    Science.gov (United States)

    Kemp, Jacqueline; Longworth, Michelle

    2015-12-01

    Retrotransposons are repetitive DNA sequences that are positioned throughout the human genome. Retrotransposons are capable of copying themselves and mobilizing new copies to novel genomic locations in a process called retrotransposition. While most retrotransposon sequences in the human genome are incomplete and incapable of mobilization, the LINE-1 retrotransposon, which comprises approximately 17% of the human genome, remains active. The disruption of cellular mechanisms that suppress retrotransposon activity is linked to the generation of aneuploidy, a potential driver of tumor development. When retrotransposons insert into a novel genomic region, they have the potential to disrupt the coding sequence of endogenous genes and alter gene expression, which can lead to deleterious consequences for the organism. Additionally, increased LINE-1 copy numbers provide more chances for recombination events to occur between retrotransposons, which can lead to chromosomal breaks and rearrangements. LINE-1 activity is increased in various cancer cell lines and in patient tissues resected from primary tumors. LINE-1 activity also correlates with increased cancer metastasis. This review aims to give a brief overview of the connections between LINE-1 retrotransposition and the loss of genome stability. We will also discuss the mechanisms that repress retrotransposition in human cells and their links to cancer.

  4. Theoretical Atomic Physics code development IV: LINES, A code for computing atomic line spectra

    International Nuclear Information System (INIS)

    Abdallah, J. Jr.; Clark, R.E.H.

    1988-12-01

    A new computer program, LINES, has been developed for simulating atomic line emission and absorption spectra using the accurate fine structure energy levels and transition strengths calculated by the (CATS) Cowan Atomic Structure code. Population distributions for the ion stages are obtained in LINES by using the Local Thermodynamic Equilibrium (LTE) model. LINES is also useful for displaying the pertinent atomic data generated by CATS. This report describes the use of LINES. Both CATS and LINES are part of the Theoretical Atomic PhysicS (TAPS) code development effort at Los Alamos. 11 refs., 9 figs., 1 tab

  5. Second-line failure and first experience with third-line antiretroviral therapy in Mumbai, India

    Directory of Open Access Journals (Sweden)

    Samsuddin Khan

    2014-07-01

    Full Text Available Background: There are limited data on the failure of second-line antiretroviral therapy (ART and the use of third-line ART in people living with HIV in resource-limited settings. Since 2011, the Médecins Sans Frontières (MSF HIV/tuberculosis programme in Mumbai, India, has been providing third-line ART to patients in care. Objective: To describe the experiences and programmatic challenges during management of suspected second-line ART failure and third-line ART therapy for patients living with HIV, including the use of HIV viral load (VL testing. Design: This was a retrospective, observational cohort study of patients with suspected second-line ART treatment failure, who were followed for at least 12 months between January 2011 and March 2014. Results: A total of 47 patients with suspected second-line failure met the inclusion criteria during the study period. Twenty-nine of them (62% responded to enhanced adherence support, had a subsequent undetectable VL after a median duration of 3 months and remained on second-line ART. The other 18 patients had to be initiated on a third-line ART regimen, which consisted of darunavir–ritonavir, raltegravir, and one or more appropriate nucleoside or nucleotide reverse transcriptase inhibitors, based on the results of HIV genotype testing. Of the 13 patients for whom follow-up VL results were available, 11 achieved virological suppression after a median duration of 3 months on third-line ART (interquartile range: 2.5–3.0. No serious treatment-related adverse events were recorded. Conclusions: With intensive counselling and adherence support in those suspected of failing second-line ART, unnecessary switching to more expensive third-line ART can be averted in the majority of cases. However, there is an increasing need for access to third-line ART medications such as darunavir and raltegravir, for which national ART programmes should be prepared. The cost of such medications and inadequate access to VL

  6. Survey of transmission line corridors. [Data on delays in transmission line construction

    Energy Technology Data Exchange (ETDEWEB)

    1979-01-05

    The intent of this study is to determine the extent of delays experienced in planning and constructing transmission lines in the continental United States. The reasons for the delays are identified for each line studied and their effect on the total electrical system is sought. Data was collected for 136 different lines either recently built or currently under study. Statistics were developed for each line in several categories and comparisons of lines delayed were made by company, area served and generation capacity. From the study presented here it was found that: right-of-way acquisition procedures including condemnation and easement negotiation practices delay more projects than local, state and federal regulatory requirements combined; load growth reductions particularly in the east have reduced the impact of regulatory delays; the south, southeast and southwestern areas of the country experience fewer delays in constructing transmission lines than the more populated states, and the cost for corridor delays was responded to for only 17 of the 142 projects surveyed. By far the most costly delay is the expense of condemning land for transmission right-of-way.

  7. LINES

    Directory of Open Access Journals (Sweden)

    Minas Bakalchev

    2015-10-01

    Full Text Available The perception of elements in a system often creates their interdependence, interconditionality, and suppression. The lines from a basic geometrical element have become the model of a reductive world based on isolation according to certain criteria such as function, structure, and social organization. Their traces are experienced in the contemporary world as fragments or ruins of a system of domination of an assumed hierarchical unity. How can one release oneself from such dependence or determinism? How can the lines become less “systematic” and forms more autonomous, and less reductive? How is a form released from modernistic determinism on the new controversial ground? How can these elements or forms of representation become forms of action in the present complex world? In this paper, the meaning of lines through the ideas of Le Corbusier, Leonidov, Picasso, and Hitchcock is presented. Spatial research was made through a series of examples arising from the projects of the architectural studio “Residential Transformations”, which was a backbone for mapping the possibilities ranging from playfulness to exactness, as tactics of transformation in the different contexts of the contemporary world.

  8. Transmission Lines or Poles, Electric - VOLUSIA COUNTY MAJOR POWER LINES (Arcs)

    Data.gov (United States)

    NSGIC Local Govt | GIS Inventory — Volusia County Power Line data was aggregated by using parcel data and visual inspection of 2005 aerial photography to determine centerline of Power Lines Right of...

  9. Flow lines and export lines of Sabalo Gas Field - the engineering of a complex job; Flow lines e export lines de Sabalo - a engenharia da complexidade

    Energy Technology Data Exchange (ETDEWEB)

    Serodio, Conrado Jose Morbach [GDK Engenharia, Salvador, BA (Brazil)

    2003-07-01

    The construction of the natural gas flow lines and export lines system of the Sabalo field, in the far South of Bolivia is an unique job in the pipeline construction area. Its execution is a turning point in terms of engineering and construction technology in this industry. Among the Aguarague Cordillera (mountains), it runs across rocky canyons for more than 5 km, a 2.100 mt long narrow tunnel to overcome the mountains and steep hills along all the ROW length, with a total extension of 70 km, in line pipes ranging from 10'' and 12'' for the flow lines, 28'' for the gas export line and 8' for the condensate line. An integrated construction work plan was settled in order to face and overcome the complex construction situations found in every feet of the pipeline. Four simultaneous work sites were mobilized, 8 independent work fronts, 700 professionals and more than 150 pieces of heavy construction equipment, brought from 3 different countries. Special techniques were adopted also to handle the challenging detail engineering . All in all, the correct conjunction of a sound engineering work, planning, human resources and equipment and the managing flexibility to create alternatives and solutions at the fast pace required by a dynamic work schedule were essential to succeed, in a job with no room for mistakes. The successfully job completion open new possibilities to other challenging projects alike.(author)

  10. Alternate Double Single Track Lines

    Energy Technology Data Exchange (ETDEWEB)

    Moraga Contreras, P.; Grande Andrade, Z.; Castillo Ron, E.

    2016-07-01

    The paper discusses the advantages and shortcomings of alternate double single track (ADST) lines with respect to double track lines for high speed lines. ADST lines consists of sequences of double and single track segments optimally selected in order to reduce the construction and maintenance costs of railway lines and to optimize the timetables used to satisfy a given demand. The single tracks are selected to coincide with expensive segments (tunnels and viaducts) and the double tracks are chosen to coincide with flat areas and only where they are necessary. At the same time, departure times are adjusted for trains to cross at the cheap double track segments. This alternative can be used for new lines and also for existing conventional lines where some new tracks are to be constructed to reduce travel time (increase speed). The ADST proposal is illustrated with some examples of both types (new lines and where conventional lines exist), including the Palencia-Santander, the Santiago-Valparaíso-Viña del Mar and the Dublin-Belfast lines, where very important reductions (90 %) are obtained, especially where a railway infrastructure already exist. (Author)

  11. Determinants of durability of first-line antiretroviral therapy regimen and time from first-line failure to second-line antiretroviral therapy initiation

    DEFF Research Database (Denmark)

    Desmonde, Sophie; Eboua, François T; Malateste, Karen

    2015-01-01

    BACKGROUND: We described reasons for switching to second-line antiretroviral treatment (ART) and time to switch in HIV-infected children failing first-line ART in West Africa. METHODS: We included all children aged 15 years or less, starting ART (at least three drugs) in the paediatric Ie...... post-ART initiation, 188 (7%) had switched to second-line. The most frequent reasons were drug stock outs (20%), toxicity (18%), treatment failure (16%) and poor adherence (8%). Over the 24-month follow-up period, 322 (12%) children failed first-line ART after a median time of 7 months...... rare and switches after an immunological failure were insufficient. These gaps reveal that it is crucial to advocate for both sustainable access to first-line and alternative regimens to provide adequate roll-out of paediatric ART programmes....

  12. Homotopic Polygonal Line Simplification

    DEFF Research Database (Denmark)

    Deleuran, Lasse Kosetski

    This thesis presents three contributions to the area of polygonal line simplification, or simply line simplification. A polygonal path, or simply a path is a list of points with line segments between the points. A path can be simplified by morphing it in order to minimize some objective function...

  13. On-line adaptive line frequency noise cancellation from a nuclear power measuring channel

    Directory of Open Access Journals (Sweden)

    Qadir Javed

    2011-01-01

    Full Text Available On-line software for adaptively canceling 50 Hz line frequency noise has been designed and tested at Pakistan Research Reactor 1. Line frequency noise causes much problem in weak signals acquisition. Sometimes this noise is so dominant that original signal is totally corrupted. Although notch filter can be used for eliminating this noise, but if signal of interest is in close vicinity of 50 Hz, then original signal is also attenuated and hence overall performance is degraded. Adaptive noise removal is a technique which could be employed for removing line frequency without degrading the desired signal. In this paper line frequency noise has been eliminated on-line from a nuclear power measuring channel. The adaptive LMS algorithm has been used to cancel 50 Hz noise. The algorithm has been implemented in labVIEW with NI 6024 data acquisition card. The quality of the acquired signal has been improved much as can be seen in experimental results.

  14. Does a more extensive mucosal excision prevent haemorrhoidal recurrence after stapled haemorrhoidopexy? Long-term outcome of a randomized controlled trial.

    Science.gov (United States)

    Altomare, D F; Pecorella, G; Tegon, G; Aquilino, F; Pennisi, D; De Fazio, M

    2017-06-01

    The study aimed in a multicentric randomized controlled trial to define the role of a more extensive mucosal resection on recurrence of mucosal prolapse in patients with Stage III haemorrhoids undergoing stapled haemorrhoidopexy. In all, 135 patients were randomized to treatment with a PPH-01/03 (Ethicon EndoSurgery) or an EEA (Covidien) stapler. They were reviewed after a minimum follow-up of 4 years to determine the rate of recurrent mucosal prolapse and general condition (wellness evaluation score). Postoperative bowel dysfunction was assessed using the Rome III criteria. Eighty-seven (65%) of the 135 patients (48 in the EEA stapler group and 37 in the PPH group) were available for long-term follow-up. The two groups were comparable for age, gender and duration of follow-up (mean 49.3 ± 5.4 months and 49.0 ± 5.3 months respectively). In the EEA group, 11 (23%) patients had some degree of recurrent prolapse compared with 12 (32%) in the PPH group (P = 0.409). Persistence of anal bleeding was significantly higher in the PPH group (P = 0.04) while the postoperative Haemorrhoid Symptom Score was significantly better in the EEA group (1.73 ± 1.65 vs 3.17 ± 1.94, P < 0.001). The wellness evaluation score was significantly better in the EEA group (1.2 ± 1.27 vs 0.6 ± 1.0, P = 0.028). Furthermore, 7 (15%) of the patients in the EEA group complained of some evacuation disturbance compared with 13 (36%) in the PPH group (P = 0.021). The study failed to demonstrate any significant difference in the long-term recurrence rate of Stage III haemorrhoids using EEA or PPH. Nevertheless, use of the larger volume EEA provides better symptom resolution compared with PPH. Colorectal Disease © 2016 The Association of Coloproctology of Great Britain and Ireland.

  15. Radiosensitivity of mesothelioma cell lines

    International Nuclear Information System (INIS)

    Haekkinen, A.M.; Laasonen, A.; Linnainmaa, K.; Mattson, K.; Pyrhoenen, S.

    1996-01-01

    The present study was carried out in order to examine the radiosensitivity of malignant pleural mesothelioma cell lines. Cell kinetics, radiation-induced delay of the cell cycle and DNA ploidy of the cell lines were also determined. For comparison an HeLa and a human foetal fibroblast cell line were simultaneously explored. Six previously cytogenetically and histologically characterized mesothelioma tumor cell lines were applied. A rapid tiazolyl blue microtiter (MTT) assay was used to analyze radiosensitivity and cell kinetics and DNA ploidy of the cultured cells were determined by flow cytometry. The survival fraction after a dose of 2 Gy (SF2), parameters α and β of the linear quadratic model (LQ-model) and mean inactivation dose (D MID ) were also estimated. The DNA index of four cell lines equaled 1.0 and two cell lines equaled 1.5 and 1.6. Different mesothelioma cell lines showed a great variation in radiosensitivity. Mean survival fraction after a radiation dose of 2 Gy (SF2) was 0.60 and ranged from 0.36 to 0.81 and mean α value was 0.26 (range 0.48-0.083). The SF2 of the most sensitive diploid mesothelioma cell line was 0.36: Less than that of the foetal fibroblast cell line (0.49). The survival fractions (0.81 and 0.74) of the two most resistant cell lines, which also were aneuploid, were equal to that of the HeLa cell line (0.78). The α/β ratios of the most sensitive cell lines were almost an order of magnitude greater than those of the two most resistant cell lines. Radiation-induced delay of the most resistant aneuploid cell line was similar to that of HeLa cells but in the most sensitive (diploid cells) there was practically no entry into the G1 phase following the 2 Gy radiation dose during 36 h. (orig.)

  16. Radiosensitivity of mesothelioma cell lines

    Energy Technology Data Exchange (ETDEWEB)

    Haekkinen, A.M. [Dept. of Oncology, Univ. Central Hospital, Helsinki (Finland); Laasonen, A. [Dept. of Pathology, Central Hospital of Etelae-Pohjanmaa, Seinaejoki (Finland); Linnainmaa, K. [Dept. of Industrial Hygiene and Toxicology, Inst. of Occupational Health, Helsinki (Finland); Mattson, K. [Dept. Pulmonary Medicine, Univ. Central Hospital, Helsinki (Finland); Pyrhoenen, S. [Dept. of Oncology, Univ. Central Hospital, Helsinki (Finland)

    1996-10-01

    The present study was carried out in order to examine the radiosensitivity of malignant pleural mesothelioma cell lines. Cell kinetics, radiation-induced delay of the cell cycle and DNA ploidy of the cell lines were also determined. For comparison an HeLa and a human foetal fibroblast cell line were simultaneously explored. Six previously cytogenetically and histologically characterized mesothelioma tumor cell lines were applied. A rapid tiazolyl blue microtiter (MTT) assay was used to analyze radiosensitivity and cell kinetics and DNA ploidy of the cultured cells were determined by flow cytometry. The survival fraction after a dose of 2 Gy (SF2), parameters {alpha} and {beta} of the linear quadratic model (LQ-model) and mean inactivation dose (D{sub MID}) were also estimated. The DNA index of four cell lines equaled 1.0 and two cell lines equaled 1.5 and 1.6. Different mesothelioma cell lines showed a great variation in radiosensitivity. Mean survival fraction after a radiation dose of 2 Gy (SF2) was 0.60 and ranged from 0.36 to 0.81 and mean {alpha} value was 0.26 (range 0.48-0.083). The SF2 of the most sensitive diploid mesothelioma cell line was 0.36: Less than that of the foetal fibroblast cell line (0.49). The survival fractions (0.81 and 0.74) of the two most resistant cell lines, which also were aneuploid, were equal to that of the HeLa cell line (0.78). The {alpha}/{beta} ratios of the most sensitive cell lines were almost an order of magnitude greater than those of the two most resistant cell lines. Radiation-induced delay of the most resistant aneuploid cell line was similar to that of HeLa cells but in the most sensitive (diploid cells) there was practically no entry into the G1 phase following the 2 Gy radiation dose during 36 h. (orig.).

  17. World lines.

    OpenAIRE

    Waser Jürgen; Fuchs Raphael; Ribicic Hrvoje; Schindler Benjamin; Blöschl Günther; Gröller Eduard

    2010-01-01

    In this paper we present World Lines as a novel interactive visualization that provides complete control over multiple heterogeneous simulation runs. In many application areas decisions can only be made by exploring alternative scenarios. The goal of the suggested approach is to support users in this decision making process. In this setting the data domain is extended to a set of alternative worlds where only one outcome will actually happen. World Lines integrate simulation visualization and...

  18. TH-C-18A-02: Machine Learning and STAPLE Based Simultaneous Longitudinal Segmentation of Bone and Marrow Structures From Dual Energy CT

    International Nuclear Information System (INIS)

    Fehr, D; Schmidtlein, C; Hwang, S; Deasy, J; Veeraraghavan, H

    2014-01-01

    Purpose: To develop a fully-automatic longitudinal bone and marrow segmentation method in the pelvic region from dual energy computed tomography (DECT). Methods: We developed a two-step automatic bone and marrow segmentation method for simultaneous longitudinal evaluation of patients with metastatic bone disease using dual energy CT (DECT). Our approach transforms the DECT images into a multi-material decomposition (MMD) model that represents the voxels as a mixture of multiple materials. A support vector machine (SVM) was trained using a single scan. In the first step of the longitudinal segmentation the trained SVM model detects bone and marrow structures on all available longitudinal scans. Segmentation is further refined through active contour segmentation. In the second step, the segmentations from the individual scans are merged by employing the simultaneous truth and performance level estimation (STAPLE) algorithm. The scans are registered using affine and deformable registration. We found that our approach improves the segmentation in all the scans under reliable registration performance between the same scans. Improving registration was not under the scope of this work. Results: We applied our approach to segment bone and marrow in DECT scans in the pelvic regions for multiple patients. Each patient had three to five follow up scans. All the patients in the analysis had artificial metal prostheses which introduced challenges for the registration. Our algorithm achieved reasonable accurate segmentation despite the presence of metal artifacts and high-density oral contrast in neighboring structures. Our approach obtained an overall segmentation accuracy of 80% using DICE metric. Conclusion: We developed a two-step automatic longitudinal segmentation technique for bone and marrow region structures in the pelvic areas from dual energy CT. Our approach achieves robust segmentation despite the presence of confounding structures with similar intensities as the

  19. Research for the Influence of Distribution Network Line Reclosing Current on Line Protection

    Directory of Open Access Journals (Sweden)

    Yu Kansheng

    2016-01-01

    Full Text Available According to the distribution network line structure and reclosing control strategy, the system simulation model of distribution network lines has established based on the real-time digital simulation RTDS. Based on this, distribution network switching impulse current characteristic has researched with different capacity, different distribution and different load power factor under the different voltage switching angles. The results of the study provide a scientific basis for distribution network line protection setting, in order to further lay the foundation for improvement the validity and reliability of distribution network line protection action.

  20. The last line effect explained

    NARCIS (Netherlands)

    Beller, M. (Moritz); Zaidman, A. (Andy); Karpov, A. (Andrey); R.A. Zwaan (Rolf)

    2017-01-01

    textabstractMicro-clones are tiny duplicated pieces of code; they typically comprise only few statements or lines. In this paper, we study the “Last Line Effect,” the phenomenon that the last line or statement in a micro-clone is much more likely to contain an error than the previous lines or

  1. Dynamic Line Rating - Technologies and Challenges of PMU on Overhead Lines

    DEFF Research Database (Denmark)

    Alvarez, David; Rosero, Javier; Silva, Filipe Miguel Faria da

    2016-01-01

    for line rating computation and monitoring are identified, these are: sensors, communications, management information system and information analysis tools, which are part of integral dynamic line rating systems. Finally, the benefits and challenges of using phasor measurement units for real time capacity...

  2. The last line effect explained

    NARCIS (Netherlands)

    Beller, M.M.; Zaidman, A.E.; Karpov, Andrey; Zwaan, Rolf A.

    Micro-clones are tiny duplicated pieces of code; they typically comprise only few statements or lines. In this paper, we study the “Last Line Effect,” the phenomenon that the last line or statement in a micro-clone is much more likely to contain an error than the previous lines or statements. We do

  3. Numerical simulations of sheared magnetic lines at the solar null line

    Science.gov (United States)

    Kuźma, B.; Murawski, K.; Solov'ev, A.

    2015-05-01

    Aims: We perform numerical simulations of sheared magnetic lines at the magnetic null line configuration of two magnetic arcades that are settled in a gravitationally stratified and magnetically confined solar corona. Methods: We developed a general analytical model of a 2.5D solar atmospheric structure. As a particular application of this model, we adopted it for the curved magnetic field lines with an inverted Y shape that compose the null line above two magnetic arcades, which are embedded in the solar atmosphere that is specified by the realistic temperature distribution. The physical system is described by 2.5D magnetohydrodynamic equations that are numerically solved by the FLASH code. Results: The magnetic field line shearing, implemented about 200 km below the transition region, results in Alfvén and magnetoacoustic waves that are able to penetrate solar coronal regions above the magnetic null line. As a result of the coupling of these waves, partial reflection from the transition region and scattering from inhomogeneous regions the Alfvén waves experience fast attenuation on time scales comparable to their wave periods, and the physical system relaxes in time. The attenuation time grows with the large amplitude and characteristic growing time of the shearing. Conclusions: By having chosen a different magnetic flux function, the analytical model we devised can be adopted to derive equilibrium conditions for a diversity of 2.5D magnetic structures in the solar atmosphere. Movie associated to Fig. 5 is available in electronic form at http://www.aanda.org

  4. Incentive-Compatible Robust Line Planning

    Science.gov (United States)

    Bessas, Apostolos; Kontogiannis, Spyros; Zaroliagis, Christos

    The problem of robust line planning requests for a set of origin-destination paths (lines) along with their frequencies in an underlying railway network infrastructure, which are robust to fluctuations of real-time parameters of the solution. In this work, we investigate a variant of robust line planning stemming from recent regulations in the railway sector that introduce competition and free railway markets, and set up a new application scenario: there is a (potentially large) number of line operators that have their lines fixed and operate as competing entities issuing frequency requests, while the management of the infrastructure itself remains the responsibility of a single entity, the network operator. The line operators are typically unwilling to reveal their true incentives, while the network operator strives to ensure a fair (or socially optimal) usage of the infrastructure, e.g., by maximizing the (unknown to him) aggregate incentives of the line operators.

  5. Development of a Handheld Line Information Reader and Generator for Efficient Management of Optical Communication Lines.

    Science.gov (United States)

    Lee, Jaeyul; Kwon, Hyungwoo; Song, Jaewon; Jeon, Mansik; Kim, Jeehyun

    2017-08-24

    A handheld line information reader and a line information generator were developed for the efficient management of optical communication lines. The line information reader consists of a photo diode, trans-impedance amplifier, voltage amplifier, microcontroller unit, display panel, and communication modules. The line information generator consists of a laser diode, laser driving circuits, microcontroller unit, and communication modules. The line information reader can detect the optical radiation field of the test line by bending the optical fiber. To enhance the sensitivity of the line information reader, an additional lens was used with a focal length of 4.51 mm. Moreover, the simulation results obtained through BeamPROP ® software from Synopsys, Inc. demonstrated a stronger optical radiation field of the fiber due to a longer transmission wavelength and larger bending angle of the fiber. Therefore, the developed devices can be considered as useful tools for the efficient management of optical communication lines.

  6. GOSAT-2014 methane spectral line list

    International Nuclear Information System (INIS)

    Nikitin, A.V.; Lyulin, O.M.; Mikhailenko, S.N.; Perevalov, V.I.; Filippov, N.N.; Grigoriev, I.M.; Morino, I.; Yoshida, Y.; Matsunaga, T.

    2015-01-01

    The updated methane spectral line list GOSAT-2014 for the 5550–6240 cm −1 region with the intensity cutoff of 5×10 –25 cm/molecule at 296 K is presented. The line list is based on the extensive measurements of the methane spectral line parameters performed at different temperatures and pressures of methane without and with buffer gases N 2 , O 2 and air. It contains the following spectral line parameters of about 12150 transitions: line position, line intensity, energy of lower state, air-induced and self-pressure-induced broadening and shift coefficients and temperature exponent of air-broadening coefficient. The accuracy of the line positions and intensities are considerably improved in comparison with the previous version GOSAT-2009. The improvement of the line list is done mainly due to the involving to the line position and intensity retrieval of six new spectra recorded with short path way (8.75 cm). The air-broadening and air-shift coefficients for the J-manifolds of the 2ν 3 (F 2 ) band are refitted using the new more precise values of the line positions and intensities. The line assignment is considerably extended. The lower state J-value was assigned to 6397 lines representing 94.4% of integrated intensity of the considering wavenumber region. The complete assignment was done for 2750 lines. - Highlights: • The upgrade of the GOSAT methane line list in the 5550–6240 cm −1 region is done. • 12,146 experimental methane line positions and intensities are retrieved. • 6376 lower energy levels for methane lines are determined

  7. Rapid line scan MR angiography

    International Nuclear Information System (INIS)

    Frahm, J.; Merboldt, K.D.; Hanicke, W.; Bruhn, H.

    1987-01-01

    Direct MR angiography may be performed using line scan imaging techniques combined with presaturation of stationary spins. Thus, a single line scan echo yields a projection of vessels due to the signal from reflowing unsaturated spins. Reconstruction of an angiographic image is performed line by line at slightly incremented positions. In particular, line scan angiography is direct and fast without a sensitivity to artifacts even for high flow rates. Image resolution and field of view may be chosen without restrictions, and zoom images using enhanced gradients may be recorded without aliasing artifacts. The method is robust with respect to eddy currents and pulsatile flow. Line scan MR angiograms of phantoms, animals, and human volunteers have been recorded using 90 0 radio frequency pulses and gradient-recalled echoes

  8. Spotting Separator Points at Line Terminals in Compressed Document Images for Text-line Segmentation

    OpenAIRE

    R, Amarnath; Nagabhushan, P.

    2017-01-01

    Line separators are used to segregate text-lines from one another in document image analysis. Finding the separator points at every line terminal in a document image would enable text-line segmentation. In particular, identifying the separators in handwritten text could be a thrilling exercise. Obviously it would be challenging to perform this in the compressed version of a document image and that is the proposed objective in this research. Such an effort would prevent the computational burde...

  9. VT Electric Transmission Line Corridors - corridor lines

    Data.gov (United States)

    Vermont Center for Geographic Information — (Link to Metadata) The ELTRN layer depicts electric transmission line corridors in Vermont. Various methods have been used to digitize features. The data layer...

  10. High-resolution Laboratory Measurements of Coronal Lines near the Fe IX Line at 171 Å

    Science.gov (United States)

    Beiersdorfer, Peter; Träbert, Elmar

    2018-02-01

    We present high-resolution laboratory measurements in the spectral region between 165 and 175 Å that focus on the emission from various ions of C, O, F, Ne, S, Ar, Fe, and Ni. This wavelength region is centered on the λ171 Fe IX channel of the Atmospheric Imaging Assembly on the Solar Dynamics Observatory, and we place special emphasis on the weaker emission lines of Fe IX predicted in this region. In general, our measurements show a multitude of weak lines missing in the current databases, where the emission lines of Ni are probably most in need of further identification and reclassification. We also find that the wavelengths of some of the known lines need updating. Using the multi-reference Møller–Plesset method for wavelength predictions and collisional-radiative modeling of the line intensities, we have made tentative assignments of more than a dozen lines to the spectrum of Fe IX, some of which have formerly been identified as Fe VII, Fe XIV, or Fe XVI lines. Several Fe features remain unassigned, although they appear to be either Fe VII or Fe X lines. Further work will be needed to complete and correct the spectral line lists in this wavelength region.

  11. VT Digital Line Graph Railroads

    Data.gov (United States)

    Vermont Center for Geographic Information — (Link to Metadata) This datalayer is comprised of major railroad lines for the state of Vermont. These railroad lines line up well along quadrangle boundaries, but...

  12. The line makes the difference: line managers as effective HRM partners

    NARCIS (Netherlands)

    Bos-Nehles, Anna Christina

    2010-01-01

    The HR role of line managers is highly discussed and criticized but little empirically researched. It is argued that line managers are not able to effectively implement HR practices because they do not have the desire, capacity and competences needed to perform well and lack support and policies &

  13. Power line communications theory and applications for narrowband and broadband communications over power lines

    CERN Document Server

    Ferreira, Hendrik C; Newbury, John; Swart, Theo G

    2010-01-01

    Power Line Communications (PLC) is a promising emerging technology, which has attracted much attention due to the wide availability of power distribution lines. This book provides a thorough introduction to the use of power lines for communication purposes, ranging from channel characterization, communications on the physical layer and electromagnetic interference, through to protocols, networks, standards and up to systems and implementations. With contributions from many of the most prominent international PLC experts from academia and industry, Power Line Communications brings togeth

  14. Optical Variability of Narrow-line and Broad-line Seyfert 1 Galaxies

    Science.gov (United States)

    Rakshit, Suvendu; Stalin, C. S.

    2017-06-01

    We studied the optical variability (OV) of a large sample of narrow-line Seyfert 1 (NLSy1) and broad-line Seyfert 1 (BLSy1) galaxies with z anti-correlated with Fe II strength but correlated with the width of the Hβ line. The well-known anti-correlation of variability-luminosity and the variability-Eddington ratio is present in our data. Among the radio-loud sample, variability amplitude is found to be correlated with radio-loudness and radio-power, suggesting that jets also play an important role in the OV in radio-loud objects, in addition to the Eddington ratio, which is the main driving factor of OV in radio-quiet sources.

  15. Improvement of cassava for high dry matter, starch and low cyanogenic glucoside content by mutation induction

    Energy Technology Data Exchange (ETDEWEB)

    Nwachukwu, E C; Mbanaso, E N.A.; Ene, L S.O. [Plant Breeding Div., National Root Crops Research Inst., Umudike, Umuahia (Nigeria)

    1997-07-01

    Cassava (Manihot esculenta Crantz) is an important food in Nigeria. One drawback in its use as a staple food is the presence of cyanogenic glucosides which on hydrolysis produce the very toxic hydrogen cyanide (HCN). To reduce the cyanogenic levels by mutation induction, three locally adopted and high yielding varieties of cassava, TMS 30572, NR 8817 and NR 84111 were irradiated with 20, 25 and 30 Gy gamma rays. There were a wide variation in HCN, dry matter and starch content of irradiated cassava plants, screened in the MV{sub 2} propagation. Fourteen cassavavariant lines were selected for low HCN content, and 22 lines for high dry matter content. These will be further tested for yield in replicated field trials. (author). 7 refs, 3 tabs.

  16. Improvement of cassava for high dry matter, starch and low cyanogenic glucoside content by mutation induction

    International Nuclear Information System (INIS)

    Nwachukwu, E.C.; Mbanaso, E.N.A.; Ene, L.S.O.

    1997-01-01

    Cassava (Manihot esculenta Crantz) is an important food in Nigeria. One drawback in its use as a staple food is the presence of cyanogenic glucosides which on hydrolysis produce the very toxic hydrogen cyanide (HCN). To reduce the cyanogenic levels by mutation induction, three locally adopted and high yielding varieties of cassava, TMS 30572, NR 8817 and NR 84111 were irradiated with 20, 25 and 30 Gy gamma rays. There were a wide variation in HCN, dry matter and starch content of irradiated cassava plants, screened in the MV 2 propagation. Fourteen cassavavariant lines were selected for low HCN content, and 22 lines for high dry matter content. These will be further tested for yield in replicated field trials. (author). 7 refs, 3 tabs

  17. Modelling DNA origami self-assembly at the domain level

    Energy Technology Data Exchange (ETDEWEB)

    Dannenberg, Frits; Kwiatkowska, Marta [Department of Computer Science, University of Oxford, Wolfson Building, Parks Road, Oxford OX1 3QD (United Kingdom); Dunn, Katherine E. [Department of Physics, University of Oxford, Clarendon Laboratory, Parks Road, Oxford OX1 3PU (United Kingdom); Department of Electronics, University of York, York YO10 5DD (United Kingdom); Bath, Jonathan; Turberfield, Andrew J. [Department of Physics, University of Oxford, Clarendon Laboratory, Parks Road, Oxford OX1 3PU (United Kingdom); Ouldridge, Thomas E. [Department of Physics, University of Oxford, Rudolf Peierls Centre for Theoretical Physics, 1 Keble Road, Oxford OX1 3NP (United Kingdom); Department of Mathematics, Imperial College, 180 Queen’s Gate, London SW7 2AZ (United Kingdom)

    2015-10-28

    We present a modelling framework, and basic model parameterization, for the study of DNA origami folding at the level of DNA domains. Our approach is explicitly kinetic and does not assume a specific folding pathway. The binding of each staple is associated with a free-energy change that depends on staple sequence, the possibility of coaxial stacking with neighbouring domains, and the entropic cost of constraining the scaffold by inserting staple crossovers. A rigorous thermodynamic model is difficult to implement as a result of the complex, multiply connected geometry of the scaffold: we present a solution to this problem for planar origami. Coaxial stacking of helices and entropic terms, particularly when loop closure exponents are taken to be larger than those for ideal chains, introduce interactions between staples. These cooperative interactions lead to the prediction of sharp assembly transitions with notable hysteresis that are consistent with experimental observations. We show that the model reproduces the experimentally observed consequences of reducing staple concentration, accelerated cooling, and absent staples. We also present a simpler methodology that gives consistent results and can be used to study a wider range of systems including non-planar origami.

  18. Modelling DNA origami self-assembly at the domain level

    International Nuclear Information System (INIS)

    Dannenberg, Frits; Kwiatkowska, Marta; Dunn, Katherine E.; Bath, Jonathan; Turberfield, Andrew J.; Ouldridge, Thomas E.

    2015-01-01

    We present a modelling framework, and basic model parameterization, for the study of DNA origami folding at the level of DNA domains. Our approach is explicitly kinetic and does not assume a specific folding pathway. The binding of each staple is associated with a free-energy change that depends on staple sequence, the possibility of coaxial stacking with neighbouring domains, and the entropic cost of constraining the scaffold by inserting staple crossovers. A rigorous thermodynamic model is difficult to implement as a result of the complex, multiply connected geometry of the scaffold: we present a solution to this problem for planar origami. Coaxial stacking of helices and entropic terms, particularly when loop closure exponents are taken to be larger than those for ideal chains, introduce interactions between staples. These cooperative interactions lead to the prediction of sharp assembly transitions with notable hysteresis that are consistent with experimental observations. We show that the model reproduces the experimentally observed consequences of reducing staple concentration, accelerated cooling, and absent staples. We also present a simpler methodology that gives consistent results and can be used to study a wider range of systems including non-planar origami

  19. Modelling DNA origami self-assembly at the domain level

    Science.gov (United States)

    Dannenberg, Frits; Dunn, Katherine E.; Bath, Jonathan; Kwiatkowska, Marta; Turberfield, Andrew J.; Ouldridge, Thomas E.

    2015-10-01

    We present a modelling framework, and basic model parameterization, for the study of DNA origami folding at the level of DNA domains. Our approach is explicitly kinetic and does not assume a specific folding pathway. The binding of each staple is associated with a free-energy change that depends on staple sequence, the possibility of coaxial stacking with neighbouring domains, and the entropic cost of constraining the scaffold by inserting staple crossovers. A rigorous thermodynamic model is difficult to implement as a result of the complex, multiply connected geometry of the scaffold: we present a solution to this problem for planar origami. Coaxial stacking of helices and entropic terms, particularly when loop closure exponents are taken to be larger than those for ideal chains, introduce interactions between staples. These cooperative interactions lead to the prediction of sharp assembly transitions with notable hysteresis that are consistent with experimental observations. We show that the model reproduces the experimentally observed consequences of reducing staple concentration, accelerated cooling, and absent staples. We also present a simpler methodology that gives consistent results and can be used to study a wider range of systems including non-planar origami.

  20. Line Shape Variability in a Sample of AGN with Broad Lines

    Indian Academy of Sciences (India)

    2016-01-27

    Jan 27, 2016 ... We give here a comparative review of the line shape variability in a sample of five type 1 AGNs, those with broad emission lines in their spectra, of the data obtained from the international long-term optical monitoring campaign coordinated by the Special Astrophysical Observatory of the Russian Academy ...

  1. Atlas transmission line breakdown analysis

    CERN Document Server

    Nielsen, K E; Ballard, E O; Elizondo, J M; Gribble, R F; McCuistian, B T; Parsons, W M

    1999-01-01

    The Atlas facility will use 24 radially converging, vertically oriented and tapered, oil insulated, triplate transmission lines between the Marx generators and the central load region. Among the requirements of the transmission lines are low inductance and high reliability. The inter-conductor gap is nominally 2 cm and the lines taper from a height of 1.75 m at the Marx end to 0.32 m at the output end. The aluminum conductors, held together by 20 insulating spacers, are assembled and inserted as a unit into radial oil-filled steel tanks. The negative, high-voltage, center conductor is 2.54-cm thick and the outer ground conductors are 1.59-cm thick. All 24 triplate transmission lines connect to a transition section at near 1 m radius that couples the transmission lines to a disk/conical solid- dielectric-insulated power flow channel transmission line terminating at the load. Peak operating voltage on the lines can be as high as 240 kV with an effective stress time of 0.8 mu s. Testing of small sections of the ...

  2. Optimization of antibody immobilization for on-line or off-line immunoaffinity chromatography

    DEFF Research Database (Denmark)

    Beyer, Natascha Helena; Schou, Christian; Højrup, Peter

    2009-01-01

    -POROS. Protein G-based matrices are very stable showing essentially no decline in performance after 50 application-wash-elution-reequilibration cycles and being easily prepared within 2-3 h of working time with a typical antibody coupling yield of above 80%. In off-line applications where constant flow....... A systematic study was conducted to determine the most versatile antibody immobilization method for use in on-line and off-line IA chromatography applications using commonly accessible immobilization methods. Four chemistries were examined using polyclonal and monoclonal antibodies and antibody fragments. We...

  3. Line-shape asymmetry of water vapor absorption lines in the 720-nm wavelength region

    Science.gov (United States)

    Grossmann, Benoist E.; Browell, Edward V.

    1991-01-01

    Spectral line-shape analyses were performed for water vapor lines broadened by argon, oxygen, and xenon in the 720-nm wavelength region. A line-shape asymmetry was observed, which is attributed to statistical dependence or correlation between velocity- and state-changing collisions. The generalized (asymmetric) Galatry profile, which results from the soft-collision profile and includes correlation between velocity- and state-changing collisions, was fitted to the observed line shapes and was found to compare favorably with the observed data. The most prominent asymmetries were observed with xenon as the buffer gas.

  4. China's Bilateral Currency Swap Lines

    OpenAIRE

    Zhitao, Lin; Wenjie, Zhan; Cheung, Yin-Wong

    2016-01-01

    We study the determinants of China’s bilateral local currency swap lines that were established since the recent global finance crisis. It is found that economic factors, political considerations, and institutional characteristics including trade intensity, economic size, strategic partnership, free trade agreement, corruption, and stability affect the decision of signing a swap line agreement. Once a swap line agreement decision is made, the size of the swap line is then mainly affected by tr...

  5. Series Transmission Line Transformer

    Science.gov (United States)

    Buckles, Robert A.; Booth, Rex; Yen, Boris T.

    2004-06-29

    A series transmission line transformer is set forth which includes two or more of impedance matched sets of at least two transmissions lines such as shielded cables, connected in parallel at one end ans series at the other in a cascading fashion. The cables are wound about a magnetic core. The series transmission line transformer (STLT) which can provide for higher impedance ratios and bandwidths, which is scalable, and which is of simpler design and construction.

  6. Cell Line Data Base: structure and recent improvements towards molecular authentication of human cell lines.

    Science.gov (United States)

    Romano, Paolo; Manniello, Assunta; Aresu, Ottavia; Armento, Massimiliano; Cesaro, Michela; Parodi, Barbara

    2009-01-01

    The Cell Line Data Base (CLDB) is a well-known reference information source on human and animal cell lines including information on more than 6000 cell lines. Main biological features are coded according to controlled vocabularies derived from international lists and taxonomies. HyperCLDB (http://bioinformatics.istge.it/hypercldb/) is a hypertext version of CLDB that improves data accessibility by also allowing information retrieval through web spiders. Access to HyperCLDB is provided through indexes of biological characteristics and navigation in the hypertext is granted by many internal links. HyperCLDB also includes links to external resources. Recently, an interest was raised for a reference nomenclature for cell lines and CLDB was seen as an authoritative system. Furthermore, to overcome the cell line misidentification problem, molecular authentication methods, such as fingerprinting, single-locus short tandem repeat (STR) profile and single nucleotide polymorphisms validation, were proposed. Since this data is distributed, a reference portal on authentication of human cell lines is needed. We present here the architecture and contents of CLDB, its recent enhancements and perspectives. We also present a new related database, the Cell Line Integrated Molecular Authentication (CLIMA) database (http://bioinformatics.istge.it/clima/), that allows to link authentication data to actual cell lines.

  7. Cell lines authentication and mycoplasma detection as minimun quality control of cell lines in biobanking.

    Science.gov (United States)

    Corral-Vázquez, C; Aguilar-Quesada, R; Catalina, P; Lucena-Aguilar, G; Ligero, G; Miranda, B; Carrillo-Ávila, J A

    2017-06-01

    Establishment of continuous cell lines from human normal and tumor tissues is an extended and useful methodology for molecular characterization of cancer pathophysiology and drug development in research laboratories. The exchange of these cell lines between different labs is a common practice that can compromise assays reliability due to contamination with microorganism such as mycoplasma or cells from different flasks that compromise experiment reproducibility and reliability. Great proportions of cell lines are contaminated with mycoplasma and/or are replaced by cells derived for a different origin during processing or distribution process. The scientific community has underestimated this problem and thousand of research experiment has been done with cell lines that are incorrectly identified and wrong scientific conclusions have been published. Regular contamination and authentication tests are necessary in order to avoid negative consequences of widespread misidentified and contaminated cell lines. Cell banks generate, store and distribute cell lines for research, being mandatory a consistent and continuous quality program. Methods implementation for guaranteeing both, the absence of mycoplasma and authentication in the supplied cell lines, has been performed in the Andalusian Health System Biobank. Specifically, precise results were obtained using real time PCR detection for mycoplasma and 10 STRs identification by capillary electrophoresis for cell line authentication. Advantages and disadvantages of these protocols are discussed.

  8. An analysis model of the secondary tunnel lining considering ground-primary support-secondary lining interaction

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Seong-Ho; Chang, Seok-Bue [Yooshin Engineering Corporation, Seoul(Korea); Lee, Sang-Duk [Ajou University, Suwon(Korea)

    2002-06-30

    It is the common practice to over design the reinforcement for the secondary tunnel lining due to the lack of rational insight into the ground loosening loads, and due to the conservative application of the empirical design methods. The main loads of the secondary lining are the ground loosening loads and the ground water pressure, and the ground load is critical in the reinforcement design of the secondary lining in the case of drained tunnel. If the external load is absent around a tunnel. the reasons of the load for secondary tunnel lining are the deterioration of the primary supports such as shotcrete, steel rib, and rock bolts. Accordingly, the analysis method considering the ground-primary supports-secondary lining interaction should be required for the rational design of the secondary tunnel lining. In this paper, the interaction was conceptually described by the simple mass-spring model and the load transfer from the ground and primary supports to the secondary lining is showed by the ground-primary supports-secondary lining reaction curves for the theoretical solution of a circular tunnel, And also, the application of this proposed model to numerical analysis is verified in order to check the potential for the tunnel with the complex analysis conditions. (author). 8 refs., 2 tabs., 7 figs.

  9. Stokes line width

    International Nuclear Information System (INIS)

    Nikiskov, A.I.; Ritus, V.I.

    1993-01-01

    The concept of Stokes line width is introduced for the asymptotic expansions of functions near an essential singularity. Explicit expressions are found for functions (switching functions) that switch on the exponentially small terms for the Dawson integral, Airy function, and the gamma function. A different, more natural representation of a function, not associated with expansion in an asymptotic series, in the form of dominant and recessive terms is obtained by a special division of the contour integral which represents the function into contributions of higher and lower saddle points. This division leads to a narrower, natural Stokes line width and a switching function of an argument that depends on the topology of the lines of steepest descent from the saddle point

  10. Comparisons on Genetic Diversity among the Isonuclear-Alloplasmic Male Sterile Lines and Their Maintainer Lines in Rice

    Directory of Open Access Journals (Sweden)

    Jin-quan LI

    2007-06-01

    Full Text Available Four sets of rice isonuclear-alloplasmic lines including 16 male sterile lines and their maintainer lines were analyzed by using 91 pairs of SSR primers to study the genetic diversity of nuclear genome and their relative relationships. A total of 169 alleles were detected in the 16 lines, with a frequency of polymorphic loci of 53.85% and an average number of alleles per locus of 1.8, and the average gene diversity was 0.228. Four sets of the isonuclear-alloplasmic male sterile lines shared 146 identical alleles, corresponding to 86.39% of the total alleles; meanwhile, there are 23 different alleles among the tested materials, being 13.61% of the total alleles. On average, 78.70% identical alleles and 21.30% different alleles of the total alleles were detected between the isonuclear-alloplasmic male sterile lines and their maintainer lines. There were 53.85% identical alleles and 46.15% different alleles of the total alleles among the homozygous allonucleus male sterile lines. The fingerprints were established for some male sterile lines and maintainer lines. All the materials tested were divided into three groups at the 0.2 genetic distance based on the cluster analysis. Eight lines of Huanong A and Huayu A (including Huanong B and Huayu B were in the first group, four lines of Kezhen A (including Kezhen B in the second group, and four lines of Zhenshan 97A (including Zhenshan 97B in the third group. For the isonuclear-alloplasmic male sterile lines, the similarity coefficient between Y (Yegong type and WA (wild abortive type or between CW (Raoping wild rice and WA type reached 87–98%.

  11. A new technique for on-line and off-line high speed computation

    International Nuclear Information System (INIS)

    Hartouni, E.P.; Jensen, D.A.; Klima, B.; Kreisler, M.N.; Rabin, M.S.Z.; Uribe, J.; Gottschalk, E.; Gara, A.; Knapp, B.C.

    1989-01-01

    A new technique for both on-line and off-line computation has been developed. With this technique, a reconstruction analysis in Elementary Particle Physics, otherwise prohibitively long, has been accomplished. It will be used on-line in an upcoming Fermilab experiment to reconstruct more than 100,000 events per second and to trigger on the basis of that information. The technique delivers 40 Giga operations per second, has a bandwidth on the order of Gigabytes per second and has a modest cost. An overview of the program, details of the system, and performance measurements are presented in this paper

  12. Effects of low-dose preoperative irradiation on low anterior anastomosis in dogs

    Energy Technology Data Exchange (ETDEWEB)

    Schauer, R.M.; Bubrick, M.P.; Feeney, D.A.; Johnston, G.R.; Rolfsmeyer, E.S.; Strom, R.L.; Hitchcock, C.R.

    Twenty mongrel dogs underwent preoperative radiation therapy to the colon and rectum using the Nominal Standard Dose Equation to simulate treatment with 2000 rads. Each dog then underwent anterior resection of the rectosigmoid, and reconstruction was randomized into two groups consisting of either handsewn or EEA-stapled anastomoses. Anastomoses were examined digitally and radiographically on the day of surgery and on the seventh postoperative day. There were three radiographic leaks among the ten dogs having the handsewn anastomoses and one radiographic leak among the ten dogs having the EEA-stapled anastomoses. There was one clinically significant leak which occurred in a dog having an EEA-stapled anastomosis and was associated with peritonitis and death. The overall leak rate was 30 per cent among dogs having handsewn anastomoses and 20 per cent among dogs with stapled anastomoses. The data suggest that an anterior resection in low colorectal anastomosis can be done safely after low-dose radiation using either handsewn or stapling techniques.

  13. Effects of low-dose preoperative irradiation on low anterior anastomosis in dogs.

    Science.gov (United States)

    Schauer, R M; Bubrick, M P; Feeney, D A; Johnston, G R; Rolfsmeyer, E S; Strom, R L; Hitchcock, C R

    1982-01-01

    Twenty mongrel dogs underwent preoperative radiation therapy to the colon and rectum using the Nominal Standard Dose Equation to simulate treatment with 2000 rads. Each dog then underwent anterior resection of the rectosigmoid, and reconstruction was randomized into two groups consisting of either handsewn or EEA-stapled anastomoses. Anastomoses were examined digitally and radiographically on the day of surgery and on the seventh postoperative day. There were three radiographic leaks among the ten dogs having the handsewn anastomoses and one radiographic leak among the ten dogs having the EEA-stapled anastomoses. There was one clinically significant leak which occurred in a dog having an EEA-stapled anastomosis and was associated with peritonitis and death. The overall leak rate was 30 per cent among dogs having handsewn anastomoses and 20 per cent among dogs with stapled anastomoses. The data suggest that an anterior resection in low colorectal anastomosis can be done safely after low-dose radiation using either handsewn or stapling techniques.

  14. Effects of low-dose preoperative irradiation on low anterior anastomosis in dogs

    International Nuclear Information System (INIS)

    Schauer, R.M.; Bubrick, M.P.; Feeney, D.A.; Johnston, G.R.; Rolfsmeyer, E.S.; Strom, R.L.; Hitchcock, C.R.

    1982-01-01

    Twenty mongrel dogs underwent preoperative radiation therapy to the colon and rectum using the Nominal Standard Dose Equation to simulate treatment with 2000 rads. Each dog then underwent anterior resection of the rectosigmoid, and reconstruction was randomized into two groups consisting of either handsewn or EEA-stapled anastomoses. Anastomoses were examined digitally and radiographically on the day of surgery and on the seventh postoperative day. There were three radiographic leaks among the ten dogs having the handsewn anastomoses and one radiographic leak among the ten dogs having the EEA-stapled anastomoses. There was one clinically significant leak which occurred in a dog having an EEA-stapled anastomosis and was associated with peritonitis and death. The overall leak rate was 30 per cent among dogs having handsewn anastomoses and 20 per cent among dogs with stapled anastomoses. The data suggest that an anterior resection in low colorectal anastomosis can be done safely after low-dose radiation using either handsewn or stapling techniques

  15. CLO : The cell line ontology

    NARCIS (Netherlands)

    Sarntivijai, Sirarat; Lin, Yu; Xiang, Zuoshuang; Meehan, Terrence F.; Diehl, Alexander D.; Vempati, Uma D.; Schuerer, Stephan C.; Pang, Chao; Malone, James; Parkinson, Helen; Liu, Yue; Takatsuki, Terue; Saijo, Kaoru; Masuya, Hiroshi; Nakamura, Yukio; Brush, Matthew H.; Haendel, Melissa A.; Zheng, Jie; Stoeckert, Christian J.; Peters, Bjoern; Mungall, Christopher J.; Carey, Thomas E.; States, David J.; Athey, Brian D.; He, Yongqun

    2014-01-01

    Background: Cell lines have been widely used in biomedical research. The community-based Cell Line Ontology (CLO) is a member of the OBO Foundry library that covers the domain of cell lines. Since its publication two years ago, significant updates have been made, including new groups joining the CLO

  16. Microwave transmission-line impedance data

    CERN Document Server

    Gunston, M A R

    1996-01-01

    A compendium of data for computing the characteristic impedance of transmission lines based on physical dimensions. Covers both conventional structures and unusual geometries, including coaxial, eccentric and elliptic coaxial, twin-wire, wire-above-ground, microstrip and derivatives, stripline, slabline and trough line. Also details numerous configurations of coupled lines.

  17. Parallel plate transmission line transformer

    NARCIS (Netherlands)

    Voeten, S.J.; Brussaard, G.J.H.; Pemen, A.J.M.

    2011-01-01

    A Transmission Line Transformer (TLT) can be used to transform high-voltage nanosecond pulses. These transformers rely on the fact that the length of the pulse is shorter than the transmission lines used. This allows connecting the transmission lines in parallel at the input and in series at the

  18. Wood pole overhead lines

    CERN Document Server

    Wareing, Brian

    2005-01-01

    This new book concentrates on the mechanical aspects of distribution wood pole lines, including live line working, environmental influences, climate change and international standards. Other topics include statutory requirements, safety, profiling, traditional and probabilistic design, weather loads, bare and covered conductors, different types of overhead systems, conductor choice, construction and maintenance. A section has also been devoted to the topic of lightning, which is one of the major sources of faults on overhead lines. The book focuses on the effects of this problem and the strate

  19. Parallel field line and stream line tracing algorithms for space physics applications

    Science.gov (United States)

    Toth, G.; de Zeeuw, D.; Monostori, G.

    2004-05-01

    Field line and stream line tracing is required in various space physics applications, such as the coupling of the global magnetosphere and inner magnetosphere models, the coupling of the solar energetic particle and heliosphere models, or the modeling of comets, where the multispecies chemical equations are solved along stream lines of a steady state solution obtained with single fluid MHD model. Tracing a vector field is an inherently serial process, which is difficult to parallelize. This is especially true when the data corresponding to the vector field is distributed over a large number of processors. We designed algorithms for the various applications, which scale well to a large number of processors. In the first algorithm the computational domain is divided into blocks. Each block is on a single processor. The algorithm folows the vector field inside the blocks, and calculates a mapping of the block surfaces. The blocks communicate the values at the coinciding surfaces, and the results are interpolated. Finally all block surfaces are defined and values inside the blocks are obtained. In the second algorithm all processors start integrating along the vector field inside the accessible volume. When the field line leaves the local subdomain, the position and other information is stored in a buffer. Periodically the processors exchange the buffers, and continue integration of the field lines until they reach a boundary. At that point the results are sent back to the originating processor. Efficiency is achieved by a careful phasing of computation and communication. In the third algorithm the results of a steady state simulation are stored on a hard drive. The vector field is contained in blocks. All processors read in all the grid and vector field data and the stream lines are integrated in parallel. If a stream line enters a block, which has already been integrated, the results can be interpolated. By a clever ordering of the blocks the execution speed can be

  20. Minnesota County Boundaries - lines

    Data.gov (United States)

    Minnesota Department of Natural Resources — Minnesota county boundaries derived from a combination of 1:24,000 scale PLS lines, 1:100,000 scale TIGER, 1:100,000 scale DLG, and 1:24,000 scale hydrography lines....

  1. A tangent subsolar merging line

    International Nuclear Information System (INIS)

    Crooker, N.U.; Siscoe, G.L.; Toffoletto, F.R.

    1990-01-01

    The authors describe a global magnetospheric model with a single subsolar merging line whose position is determined neither locally by the relative orientations and strengths of the merging fields nor globally by the orientation of a separator line--the governing parameters of most previous models--but by the condition of tangential contact between the external field and the magnetopause. As in previous models, the tilt of the merging line varies with IMF orientation, but here it also depends upon the ratio of Earth's magnetic flux that leaks out of the magnetopause to IMF flux that penetrates in. In the limiting case treated by Alekseyev and Belen'kaya, with no leakage of Earth's field and total IMF penetration, the merging line forms a great circle around a spherical magnetosphere where undeviated IMF lines lie tangent to its surface. This tangent merging line lies perpendicular to the IMF. They extend their work to the case of finite leakage and partial penetration, which distort the IMF into a draped pattern, thus changing the locus of tangency to the sphere. In the special case where the penetrating IMF flux is balanced by an equal amount of Earth flux leakage, the tangent merging line bisects the angle between the IMF and Earth's northward subsolar field. This result is identical to the local merging line model result for merging fields with equal magnitude. Here a global flux balance condition replaces the local equal magnitude condition

  2. Transmission line capital costs

    International Nuclear Information System (INIS)

    Hughes, K.R.; Brown, D.R.

    1995-05-01

    The displacement or deferral of conventional AC transmission line installation is a key benefit associated with several technologies being developed with the support of the U.S. Department of Energy's Office of Energy Management (OEM). Previous benefits assessments conducted within OEM have been based on significantly different assumptions for the average cost per mile of AC transmission line. In response to this uncertainty, an investigation of transmission line capital cost data was initiated. The objective of this study was to develop a database for preparing preliminary estimates of transmission line costs. An extensive search of potential data sources identified databases maintained by the Bonneville Power Administration (BPA) and the Western Area Power Administration (WAPA) as superior sources of transmission line cost data. The BPA and WAPA data were adjusted to a common basis and combined together. The composite database covers voltage levels from 13.8 to 765 W, with cost estimates for a given voltage level varying depending on conductor size, tower material type, tower frame type, and number of circuits. Reported transmission line costs vary significantly, even for a given voltage level. This can usually be explained by variation in the design factors noted above and variation in environmental and land (right-of-way) costs, which are extremely site-specific. Cost estimates prepared from the composite database were compared to cost data collected by the Federal Energy Regulatory Commission (FERC) for investor-owned utilities from across the United States. The comparison was hampered because the only design specifications included with the FERC data were voltage level and line length. Working within this limitation, the FERC data were not found to differ significantly from the composite database. Therefore, the composite database was judged to be a reasonable proxy for estimating national average costs

  3. MEMS-based transmission lines for microwave applications

    Science.gov (United States)

    Wu, Qun; Fu, Jiahui; Gu, Xuemai; Shi, Huajuan; Lee, Jongchul

    2003-04-01

    This paper mainly presents a briefly review for recent progress in MEMS-based transmission lines for use in microwave and millimeterwave range. MEMS-based transmission lines including different transmission line structure such as membrane-supported microstrip line microstrip line, coplanar microshield transmission line, LIGA micromachined planar transmission line, micromachined waveguides and coplanar waveguide are discussed. MEMS-based transmission lines are characterized by low propagation loss, wide operation frequency band, low dispersion and high quality factor, in addition, the fabrication is compatible with traditional processing of integrated circuits (IC"s). The emergence of MEMS-based transmission lines provided a solution for miniaturizing microwave system and monolithic microwave integrated circuits.

  4. Silver linings.

    Science.gov (United States)

    Bultas, Margaret W; Pohlman, Shawn

    2014-01-01

    The purpose of this interpretive phenomenological study was to gain a better understanding of the experiences of 11 mothers of preschool children with autism spectrum disorder (ASD). Mothers were interviewed three times over a 6 week period. Interviews were analyzed using interpretive methods. This manuscript highlights one particular theme-a positive perspective mothers described as the "silver lining." This "silver lining" represents optimism despite the adversities associated with parenting a child with ASD. A deeper understanding of this side of mothering children with ASD may help health care providers improve rapport, communication, and result in more authentic family centered care. Copyright © 2014 Elsevier Inc. All rights reserved.

  5. Constancy of spectral-line bisectors

    International Nuclear Information System (INIS)

    Gray, D.F.

    1983-01-01

    Bisectors of spectral line profiles in cool stars indicate the strength of convection in the photospheres of these objects. The present investigation is concerned with the feasibility of studying time variations in line bisectors, the reality of apparent line-to-line differences within the same stellar spectrum, and bisector differences between stars of identical spectral types. The differences considered pertain to the shape of the bisector. The material used in the investigation was acquired at the McDonald Observatory using a 1728 diode Reticon array at the coudefocus of the 2.1-m telescope. Observed bisector errors are discussed. It is established that different lines in the same star show significantly different bisectors. The observed error bands are shown by the shaded regions. The slope and curvature are unique for each case

  6. Intra lines uniformity and inter lines variation of rice mutants resulting from irradiation of South Kalimantan local varieties

    International Nuclear Information System (INIS)

    Raihani Wahdah; Gusti Rumayadi; Rahmi Zulhidiani

    2016-01-01

    The preference of farmer in tidal swamp on local rice varieties are quite high, but local varieties have a long life and low yield characters, so it needs to be improved for the trait. This study is part of activities of the local rice varieties improvement to generate promising lines were short-moderate aged, but the slimming and pera (high amylose content) grains maintained. The aims of this study were to determine the intra lines uniformity and the inter lines variation of M5 generation of rice mutant lines. The experiment was carried out in the Experimental Station of Agriculture Faculty, Lambung Mangkurat University from March to September 2014. The experiment used 150 earliest flowering lines of 300 M5 mutant lines that were planted. Intra lines uniformity were analysed by comparing the variance of each mutant lines with variance of its parent, while the variation among lines were analyzed by comparing the variance of all lines with variance of its parent. More than 85 % M5 mutant lines from Siam Harli as parent and > 79 % of Siam Kuatek as parent are uniform. The uniform character at all M5 mutant lines, both of Siam Harli or Siam Kuatek parent are the harvest age, the filled grains number, and the empty grains number. There is no variability between M5 mutant lines, but some of M5 mutant lines from Siam Harli and Siam Kuatek have some better characters than their parents, so there is an opportunity for selection. (author)

  7. Mjollnir Rotational Line Scan Diagnostics.

    Science.gov (United States)

    1981-05-19

    using long cavity. M8 Removable Pellicle Beam Splitter for He-Ne Lineup Beam. Removed before HF or DF laser is turned on. 27 A 27 * A r of the chopper...three probe laser lines, however three lines were sequentially measured to verify the diagnostic equipment. Two of the three lines have been monitored

  8. QSOs with narrow emission lines

    International Nuclear Information System (INIS)

    Baldwin, J.A.; Mcmahon, R.; Hazard, C.; Williams, R.E.

    1988-01-01

    Observations of two new high-redshift, narrow-lined QSOs (NLQSOs) are presented and discussed together with observations of similar objects reported in the literature. Gravitational lensing is ruled out as a possible means of amplifying the luminosity for one of these objects. It is found that the NLQSOs have broad bases on their emission lines as well as the prominent narrow cores which define this class. Thus, these are not pole-on QSOs. The FWHM of the emission lines fits onto the smoothly falling tail of the lower end of the line-width distribution for complete QSO samples. The equivalent widths of the combined broad and narrow components of the lines are normal for QSOs of the luminosity range under study. However, the NLQSOs do show ionization differences from broader-lined QSOs; most significant, the semiforbidden C III/C IV intensity ratio is unusually low. The N/C abundance ratio in these objects is found to be normal; the Al/C abundance ratio may be quite high. 38 references

  9. Teaching Braille Line Tracking Using Stimulus Fading

    Science.gov (United States)

    Scheithauer, Mindy C.; Tiger, Jeffrey H.

    2014-01-01

    Line tracking is a prerequisite skill for braille literacy that involves moving one's finger horizontally across a line of braille text and identifying when a line ends so the reader may reset his or her finger on the subsequent line. Current procedures for teaching line tracking are incomplete, because they focus on tracking lines with only…

  10. Line ratios and wavelengths of helium-like argon n=2 satellite transitions and resonance lines

    International Nuclear Information System (INIS)

    Biedermann, C.; Radtke, R.; Fournier, K.

    2003-01-01

    The characteristic X-ray emission from helium-like argon was investigated as a mean to diagnose hot plasmas. We have measured the radiation from n=2-1 parent lines and from KLn dielectronic recombination satellites with high wavelength resolution as function of the excitation energy using the Berlin Electron Beam Ion Trap. Values of wavelength relative to the resonance and forbidden line are tabulated and compared with references. The line intensity observed over a wide range of excitation energies is weighted with a Maxwellian electron-energy distribution to analyze line ratios as function of plasma temperature. Line ratios (j+z)/w and k/w compare nicely with theoretical predictions and demonstrate their applicability as temperature diagnostic. The ratio z/(x+y) shows not to depend on the electron density

  11. LED-Based High-Voltage Lines Warning System

    Directory of Open Access Journals (Sweden)

    Eldar MUSA

    2013-04-01

    Full Text Available LED-based system, running with the current of high-voltage lines and converting the current flowing through the line into the light by using a toroid transformer, has been developed. The transformer’s primary winding is constituted by the high voltage power line. Toroidal core consists of two equal parts and the secondary windings are evenly placed on these two parts. The system is mounted on the high-voltage lines as a clamp. The secondary winding ends are connected in series by the connector on the clamp. LEDs are supplied by the voltage at the ends of secondary. Current flowing through highvoltage transmission lines is converted to voltage by the toroidal transformer and the light emitting LEDs are supplied with this voltage. The theory of the conversion of the current flowing through the line into the light is given. The system, running with the current of the line and converting the current into the light, has been developed. System has many application areas such as warning high voltage lines (warning winches to not hinder the high-voltage lines when working under the lines, warning planes to not touch the high-voltage lines, remote measurement of high-voltage line currents, and local illumination of the line area

  12. In-Vitro Corrosion Studies of Bioabsorbable Alloys

    Science.gov (United States)

    Gill, P.; Munroe, N.

    Magnesium alloys have inspired a significant amount of attention from researchers all over the world for cardiovascular and orthopedic applications due to their light weight, mechanical integrity and degradation behavior. In this investigation, cast manufactured binary, ternary and quaternary magnesium alloys were studied for their degradation behavior by potentiodynamic polarization tests in phosphate buffer saline solution (PBS) and PBS containing amino acids (cysteine, C and tryptophan, W) at 37 °C. Electrochemical impedance spectroscopy (EIS) tests were performed to determine the charge transfer resistance and immersion tests were performed to assess corrosion rate and hydrogen evolution from the alloys. Furthermore, the surface morphology and surface chemistry of the alloys were observed by scanning electron microscopy (SEM) and X-ray diffraction (XRD).

  13. Effect of splitting a mixed-model line on shortening the line length under open- and closed-boundary working area settings

    Science.gov (United States)

    Zhang, Donghao; Matsuura, Haruki; Asada, Akiko

    2017-04-01

    Some automobile factories have segmented mixed-model production lines into shorter sub-lines according to part group, such as engine, trim, and powertrain. The effects of splitting a line into sub-lines have been reported from the standpoints of worker motivation, productivity improvement, and autonomy based on risk spreading. There has been no mention of the possibility of shortening the line length by altering the product sequence using sub-lines. The purpose of the present paper is to determine the conditions under which sub-lines reduce the line length and the degree to which the line length may be shortened. The line lengths for a non-split line and a line that has been split into sub-lines are compared using three methods for determining the working area, the standard closed boundary, the optimized open boundary, and real-life constant-length stations. The results are discussed by analyzing the upper and lower bounds of the line length. Based on these results, a procedure for deciding whether or not to split a production line is proposed.

  14. Development of Elite BPH-Resistant Wide-Spectrum Restorer Lines for Three and Two Line Hybrid Rice.

    Science.gov (United States)

    Fan, Fengfeng; Li, Nengwu; Chen, Yunping; Liu, Xingdan; Sun, Heng; Wang, Jie; He, Guangcun; Zhu, Yingguo; Li, Shaoqing

    2017-01-01

    Hybrid rice has contributed significantly to the world food security. Breeding of elite high-yield, strong-resistant broad-spectrum restorer line is an important strategy for hybrid rice in commercial breeding programs. Here, we developed three elite brown planthopper (BPH)-resistant wide-spectrum restorer lines by pyramiding big-panicle gene Gn8.1 , BPH-resistant genes Bph6 and Bph9 , fertility restorer genes Rf3, Rf4, Rf5 , and Rf6 through molecular marker assisted selection. Resistance analysis revealed that the newly developed restorer lines showed stronger BPH-resistance than any of the single-gene donor parent Luoyang-6 and Luoyang-9. Moreover, the three new restorer lines had broad spectrum recovery capabilities for Honglian CMS, Wild abortive CMS and two-line GMS sterile lines, and higher grain yields than that of the recurrent parent 9,311 under nature field conditions. Importantly, the hybrid crosses also showed good performance for grain yield and BPH-resistance. Thus, the development of elite BPH-resistant wide-spectrum restorer lines has a promising future for breeding of broad spectrum BPH-resistant high-yield varieties.

  15. Cluster Analysis of Maize Inbred Lines

    Directory of Open Access Journals (Sweden)

    Jiban Shrestha

    2016-12-01

    Full Text Available The determination of diversity among inbred lines is important for heterosis breeding. Sixty maize inbred lines were evaluated for their eight agro morphological traits during winter season of 2011 to analyze their genetic diversity. Clustering was done by average linkage method. The inbred lines were grouped into six clusters. Inbred lines grouped into Clusters II had taller plants with maximum number of leaves. The cluster III was characterized with shorter plants with minimum number of leaves. The inbred lines categorized into cluster V had early flowering whereas the group into cluster VI had late flowering time. The inbred lines grouped into the cluster III were characterized by higher value of anthesis silking interval (ASI and those of cluster VI had lower value of ASI. These results showed that the inbred lines having widely divergent clusters can be utilized in hybrid breeding programme.

  16. Authentication of M14 melanoma cell line proves misidentification of MDA‐MB‐435 breast cancer cell line

    Science.gov (United States)

    Korch, Christopher; Hall, Erin M.; Dirks, Wilhelm G.; Ewing, Margaret; Faries, Mark; Varella‐Garcia, Marileila; Robinson, Steven; Storts, Douglas; Turner, Jacqueline A.; Wang, Ying; Burnett, Edward C.; Healy, Lyn; Kniss, Douglas; Neve, Richard M.; Nims, Raymond W.; Reid, Yvonne A.; Robinson, William A.

    2017-01-01

    A variety of analytical approaches have indicated that melanoma cell line UCLA‐SO‐M14 (M14) and breast carcinoma cell line MDA‐MB‐435 originate from a common donor. This indicates that at some point in the past, one of these cell lines became misidentified, meaning that it ceased to correspond to the reported donor and instead became falsely identified (through cross‐contamination or other means) as a cell line from a different donor. Initial studies concluded that MDA‐MB‐435 was the misidentified cell line and M14 was the authentic cell line, although contradictory evidence has been published, resulting in further confusion. To address this question, we obtained early samples of the melanoma cell line (M14), a lymphoblastoid cell line from the same donor (ML14), and donor serum preserved at the originator's institution. M14 samples were cryopreserved in December 1975, before MDA‐MB‐435 cells were established in culture. Through a series of molecular characterizations, including short tandem repeat (STR) profiling and cytogenetic analysis, we demonstrated that later samples of M14 and MDA‐MB‐435 correspond to samples of M14 frozen in 1975, to the lymphoblastoid cell line ML14, and to the melanoma donor's STR profile, sex and blood type. This work demonstrates conclusively that M14 is the authentic cell line and MDA‐MB‐435 is misidentified. With clear provenance information and authentication testing of early samples, it is possible to resolve debates regarding the origins of problematic cell lines that are widely used in cancer research. PMID:28940260

  17. Line lessons: Enbridge's Northern Line provides valuable information

    Energy Technology Data Exchange (ETDEWEB)

    Ross, E.

    2000-02-01

    Experiences gained from the 14-year old Norman Wells crude oil pipeline in the Northwest Territories may provide operators with valuable insights in natural gas pipeline developments in northern Canada. The Norman Wells line is the first and only long-distance pipeline in North America buried in permafrost and has proven to be a veritable laboratory on pipeline behaviour in extremely cold climates which also happen to be discontinuous at the same time. The line was built by Enbridge with a 'limit state' design, i e. it was built to move within the permafrost within certain limits, the amount of movement depending upon the area in which the line was built. This technology, which is still cutting edge, allows the pipeline to react to the freeze-thaw cycle without being affected by the heaving and resettling. The knowledge gained from the Norman Wells Line has come in very useful in the more recent AltaGas Services project transporting natural gas from a nearby well into the the town of Inuvik. Enbridge also contributed to the development of various pipeline inspection tools such as the 'Geopig' which travels within the pipeline and can pinpoint the location of problems practically within a matter of inches, and the 'Rolligon' an amphibious vehicle with five-foot diameter rubber tires that displaces only two pounds per square inch, leaving barely a track as it travels along the right-of-way during times other than winter.

  18. Reconstruction of the esophagojejunostomy by double stapling method using EEA™ OrVil™ in laparoscopic total gastrectomy and proximal gastrectomy

    Directory of Open Access Journals (Sweden)

    Yano Seiji

    2011-05-01

    Full Text Available Abstract Here we report the method of anastomosis based on double stapling technique (hereinafter, DST using a trans-oral anvil delivery system (EEATM OrVilTM for reconstructing the esophagus and lifted jejunum following laparoscopic total gastrectomy or proximal gastric resection. As a basic technique, laparoscopic total gastrectomy employed Roux-en-Y reconstruction, laparoscopic proximal gastrectomy employed double tract reconstruction, and end-to-side anastomosis was used for the cut-off stump of the esophagus and lifted jejunum. We used EEATM OrVilTM as a device that permitted mechanical purse-string suture similarly to conventional EEA, and endo-Surgitie. After the gastric lymph node dissection, the esophagus was cut off using an automated stapler. EEATM OrVilTM was orally and slowly inserted from the valve tip, and a small hole was created at the tip of the obliquely cut-off stump with scissors to let the valve tip pass through. Yarn was cut to disconnect the anvil from a tube and the anvil head was retained in the esophagus. The end-Surgitie was inserted at the right subcostal margin, and after the looped-shaped thread was wrapped around the esophageal stump opening, assisting Maryland forceps inserted at the left subcostal and left abdomen were used to grasp the left and right esophageal stump. The surgeon inserted anvil grasping forceps into the right abdomen, and after grasping the esophagus with the forceps, tightened the end Surgitie, thereby completing the purse-string suture on the esophageal stump. The main unit of the automated stapler was inserted from the cut-off stump of the lifted jejunum, and a trocar was made to pass through. To prevent dropout of the small intestines from the automated stapler, the automated stapler and the lifted jejunum were fastened with silk thread, the abdomen was again inflated, and the lifted jejunum was led into the abdominal cavity. When it was confirmed that the automated stapler and center rod

  19. Line width and line shape analysis in the inductively coupled plasma by high resolution Fourier transform spectrometry

    International Nuclear Information System (INIS)

    Faires, L.M.; Palmer, B.A.; Brault, J.W.

    1984-01-01

    High resolution Fourier transform spectrometry has been used to perform line width and line shape analysis of eighty-one iron I emision lines in the spectral range 290 to 390nm originating in the normal analytical zone of an inductively coupled plasma. Computer programs using non-linear least squares fitting techniques for line shape analysis were applied to the fully resolved spectra to determine Gaussian and Lorentzian components of the total observed line width. The effect of noise in the spectrum on the precision of the line fitting technique was assessed, and the importance of signal to noise ratio for line shape analysis is discussed. Translational (Doppler) temperatures were calculated from the Gaussian components of the line width and were found to be on the order of 6300 0 K. The excitation temperature of iron I was also determined from the same spectral data by the spectroscopic slope method based on the Einstein-Boltzmann expression for spectral intensity and was found to be on the order of 4700 0 K. 31 references

  20. POLA KONSUMSI DAN PERMINTAAN PANGAN POKOK BERDASARKAN ANALISIS DATA SUSENAS 2005

    Directory of Open Access Journals (Sweden)

    Anna Vipta Resti Mauludyani

    2012-03-01

    Full Text Available 800x600 Normal 0 false false false IN X-NONE X-NONE MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-parent:""; mso-padding-alt:0cm 5.4pt 0cm 5.4pt; mso-para-margin:0cm; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:10.0pt; font-family:"Calibri","sans-serif"; mso-bidi-font-family:"Times New Roman";} Food demand can be found dynamic, altering by the change in price and income. How great the influence of those changes to food consumption is the important information as the basic consideration for government in creating policy related to food consumption. The objective of the research, which has survey design, was to analyze staple food consumption and demand pattern in household in Indonesia. The research was conducted in Bogor, from March to June 2008 by using secondary data Susenas year 2005 with 64.709 households as the samples. The staple food analyzed were rice, corn, cassava, sweet potato, wheat flour and its derived product (instant noodle, noodle. Data was processed by SAS program version 6.12 and Double-Log Regression econometrical model. Then, it was analyzed descriptively. Result shows that rice has the biggest expenditure proportion among staple food. Almost all staple food is obtained by purchasing, except in corn, cassava, and sweet potatoes. Energy contribution from rice reaches half of total energy consumption. The consumption of rice, corn, cassava, sweet potatoes, wheat flour and its derived product, instant noodle, and wheat noodle per capita per year are 100.52 kg, 3.36 kg, 11.67 kg, 4.10 kg, 5.09 kg, 3.39 kg, and 0.22 kg. Staple food which has consumption participation level almost 100% is rice. The own price elasticity of staple foods are not elastic, except in corn, wheat flour and its derived product. The income elasticity of all staple

  1. Nuclear gamma ray lines from supernovae

    International Nuclear Information System (INIS)

    Jardim, J.O.D.

    1980-01-01

    From theoretical considerations of the behaviour of gamma ray line fluxes occurring after a supernova explosion, the 1.156 and 0.847 MeV lines are seen to be the most likely to be observed. The 1.156 MeV line has been previously observed by other investigators. Observations of the 0.847 MeV line, and 1.332, 1.173 and 0.059 MeV lines using a Ge(Li) telescope aboard a stratospheric balloon which was flown in Brazil in 1977 are reported. The observation using a NaI(Tl) detector of a line in the energy interval 1.5 - 1.6 MeV, which may be due to 0 18 (p,p') 0 18 sup (*) reaction is also reported. (Author) [pt

  2. Line profile variations in selected Seyfert galaxies

    International Nuclear Information System (INIS)

    Kollatschny, W; Zetzl, M; Ulbrich, K

    2010-01-01

    Continua as well as the broad emission lines in Seyfert 1 galaxies vary in different galaxies with different amplitudes on typical timescales of days to years. We present the results of two independent variability campaigns taken with the Hobby-Eberly Telescope. We studied in detail the integrated line and continuum variations in the optical spectra of the narrow-line Seyfert galaxy Mrk 110 and the very broad-line Seyfert galaxy Mrk 926. The broad-line emitting region in Mrk 110 has radii of four to 33 light-days as a function of the ionization degree of the emission lines. The line-profile variations are matched by Keplerian disk models with some accretion disk wind. The broad-line region in Mrk 926 is very small showing an extension of two to three light-days only. We could detect a structure in the rms line-profiles as well as in the response of the line profile segments of Mrk 926 indicating the BLR is structured.

  3. Second-Line Therapy for Advanced NSCLC.

    Science.gov (United States)

    Weiss, Jared M; Stinchcombe, Thomas E

    2013-01-01

    Most patients with lung cancer have non-small cell lung cancer (NSCLC) subtype and have advanced disease at the time of diagnosis. Improvements in both first-line and subsequent therapies are allowing longer survival and enhanced quality of life for these patients. The median overall survival observed in many second-line trials is approximately 9 months, and many patients receive further therapy after second-line therapy. The cytotoxic agents pemetrexed and docetaxel and the epidermal growth factor receptor (EGFR) tyrosine kinase inhibitors (TKIs) erlotinib and gefitinib are standard second-line therapies. For patients with EGFR mutation, a TKI is the favored second-line therapy if not already used in first-line therapy. For patients without the EGFR mutation, TKIs are an option, but many oncologists favor cytotoxic therapy. The inhibitor of the EML4/ALK fusion protein, crizotinib, has recently become a standard second-line treatment for patients with the gene rearrangement and has promise for patients with the ROS1 rearrangement.

  4. PIXE analysis of U and Pu from hot particles: K-lines vs L-lines

    DEFF Research Database (Denmark)

    Jiménez-Ramos, M.C.; García López, J.; Eriksson, M.

    2012-01-01

    . (2007) [1] and Jiménez-Ramos et al. (2010) [2], radioactive particles from aircraft accidents in Palomares and Thule have been characterized. Using micro-Proton Induced X-ray Emission (μ-PIXE) and confocal X-ray fluorescence microprobe (μ-XRF), the L-lines of the main components in these particles, U......-lines present not overlapping between the main peaks in the spectra and the X-ray absorption in the sample is much lower than for L-lines....

  5. Transmission Line Security Monitor: Final Report

    Energy Technology Data Exchange (ETDEWEB)

    John Svoboda

    2011-04-01

    The Electric Power Transmission Line Security Monitor System Operational Test is a project funded by the Technical Support Working Group (TSWG). TSWG operates under the Combating Terrorism Technical Support Office that functions under the Department of Defense. The Transmission Line Security Monitor System is based on technology developed by Idaho National Laboratory. The technology provides a means for real-time monitoring of physical threats and/or damage to electrical transmission line towers and conductors as well as providing operational parameters to transmission line operators to optimize transmission line operation. The end use is for monitoring long stretches of transmission lines that deliver electrical power from remote generating stations to cities and industry. These transmission lines are generally located in remote transmission line corridors where security infrastructure may not exist. Security and operational sensors in the sensor platform on the conductors take power from the transmission line and relay security and operational information to operations personnel hundreds of miles away without relying on existing infrastructure. Initiated on May 25, 2007, this project resulted in pre-production units tested in realistic operational environments during 2010. A technology licensee, Lindsey Manufacturing of Azusa California, is assisting in design, testing, and ultimately production. The platform was originally designed for a security monitoring mission, but it has been enhanced to include important operational features desired by electrical utilities.

  6. Alveolar bone repair with strontium- containing nanostructured carbonated hydroxyapatite

    Directory of Open Access Journals (Sweden)

    André Boziki Xavier do Carmo

    2018-01-01

    Full Text Available ABSTRACT Objective: This study aimed to evaluate bone repair in rat dental sockets after implanting nanostructured carbonated hydroxyapatite/sodium alginate (CHA and nanostructured carbonated hydroxyapatite/sodium alginate containing 5% strontium microspheres (SrCHA as bone substitute materials. Methods: Twenty male Wistar rats were randomly divided into two experimental groups: CHA and SrCHA (n=5/period/group. After one and 6 weeks of extraction of the right maxillary central incisor and biomaterial implantation, 5 μm bone blocks were obtained for histomorphometric evaluation. The parameters evaluated were remaining biomaterial, loose connective tissue and newly formed bone in a standard area. Statistical analysis was performed by Mann-Withney and and Wilcoxon tests at 95% level of significance. Results: The histomorphometric results showed that the microspheres showed similar fragmentation and bio-absorbation (p>0.05. We observed the formation of new bones in both groups during the same experimental periods; however, the new bone formation differed significantly between the weeks 1 and 6 (p=0.0039 in both groups. Conclusion: The CHA and SrCHA biomaterials were biocompatible, osteoconductive and bioabsorbable, indicating their great potential for clinical use as bone substitutes.

  7. Safety of low anterior resection in the presence of chronic radiation changes in dogs

    International Nuclear Information System (INIS)

    Meese, D.L.; Bubrick, M.P.; Paulson, G.L.; Feeney, D.A.; Johnston, G.R.; Strom, R.L.; Hitchcock, C.R.

    1986-01-01

    Thirty mongrel dogs underwent 4000- or 5000-rad single treatment orthovoltage irradiation to the pelvis according to the nominal standard dose equation. Following a resting period of six months, 21 dogs were randomized to low anterior resection with either stapled or handsewn anastomoses. Anastomotic leaks were evaluated on clinical and radiographic grounds. The radiographic leak rate was 81 percent for sutured and 0 percent for stapled anastomoses. The clinical leak rate was 18 percent for sutured and 0 percent for stapled anastomoses. The difference between the 4000- and 5000-rad groups was not significant. The data suggest that late effects of irradiation do not preclude the safe construction of low anterior anastomoses, and that the circular stapling device is superior to hand-sewn techniques

  8. The stapl Skeleton Framework

    KAUST Repository

    Zandifar, Mani; Thomas, Nathan; Amato, Nancy M.; Rauchwerger, Lawrence

    2015-01-01

    from programmers and enables them to express parallel programs as a composition of existing elementary skeletons such as map, map-reduce, scan, zip, butterfly, allreduce, alltoall and user-defined custom skeletons. Skeletons in this framework

  9. Reduction of the visual impact of overhead transmission line systems through utilisation of line surge arresters as lightning protection

    DEFF Research Database (Denmark)

    Sørensen, Thomas Kjærsgaard; Holbøll, Joachim

    2008-01-01

    with the Technical University of Denmark, on how to lessen the visual impact of 400 kV overhead line transmission systems. In this paper omission of shield wires combined with installation of a suitable number of line surge arresters is investigated as a possible alternative to transmission lines equipped...... with shielding wires thereby reducing tower height, allowing more compact designs of towers thus minimizing the visual environment impact of the lines. Omission of shield wires in the system and instead utilizing a larger number of surge arresters in the (upper) phases of an overhead line without reduction...... will be investigated by transient simulations on a 400 kV line with either shield wires or line surge arresters. These simulations will also be used to estimate number and location of the line surge arresters in the line to ensure a satisfactory performance of the line when omitting shield wires in the tower top...

  10. Transmission of radioiodine through sampling lines

    International Nuclear Information System (INIS)

    Unrein, P.J.; Pelletier, C.A.; Cline, J.E.; Voilleque, P.G.

    1985-01-01

    An experimental program to measure radioiodine transmission through sampling lines is described. The transmission depends upon both deposition on and resuspension from the walls of the line. The deposition and resuspension processes are themselves controlled by the length, diameter, and material of the line and the conditions under which it is operated. The operating conditions under study are sampling flow rate, temperature and relative humidity. Measurement results have been interpreted in terms of a four-compartment model of radioiodine deposition and resuspension. The model is applied to each of twenty or more segments of the line. Experimental measurements of short-term transmission fractions and the deposition velocities derived from them are presented for six lines. Data on resuspension rates for the same lines were obtained and are also discussed

  11. DETECTION OF REST-FRAME OPTICAL LINES FROM X-SHOOTER SPECTROSCOPY OF WEAK EMISSION-LINE QUASARS

    International Nuclear Information System (INIS)

    Plotkin, Richard M.; Gallo, Elena; Shemmer, Ohad; Trakhtenbrot, Benny; Anderson, Scott F.; Brandt, W. N.; Luo, Bin; Schneider, Donald P.; Fan, Xiaohui; Lira, Paulina; Richards, Gordon T.; Strauss, Michael A.; Wu, Jianfeng

    2015-01-01

    Over the past 15 yr, examples of exotic radio-quiet quasars with intrinsically weak or absent broad emission line regions (BELRs) have emerged from large-scale spectroscopic sky surveys. Here, we present spectroscopy of seven such weak emission line quasars (WLQs) at moderate redshifts (z = 1.4–1.7) using the X-shooter spectrograph, which provides simultaneous optical and near-infrared spectroscopy covering the rest-frame ultraviolet (UV) through optical. These new observations effectively double the number of WLQs with spectroscopy in the optical rest-frame, and they allow us to compare the strengths of (weak) high-ionization emission lines (e.g., C iv) to low-ionization lines (e.g., Mg ii, Hβ, Hα) in individual objects. We detect broad Hβ and Hα emission in all objects, and these lines are generally toward the weaker end of the distribution expected for typical quasars (e.g., Hβ has rest-frame equivalent widths ranging from 15–40 Å). However, these low-ionization lines are not exceptionally weak, as is the case for high-ionization lines in WLQs. The X-shooter spectra also display relatively strong optical Fe ii emission, Hβ FWHM ≲ 4000 km s −1 , and significant C iv blueshifts (≈1000–5500 km s −1 ) relative to the systemic redshift; two spectra also show elevated UV Fe ii emission, and an outflowing component to their (weak) Mg ii emission lines. These properties suggest that WLQs are exotic versions of “wind-dominated” quasars. Their BELRs either have unusual high-ionization components, or their BELRs are in an atypical photoionization state because of an unusually soft continuum

  12. Spectral Line Shapes. Proceedings

    International Nuclear Information System (INIS)

    Zoppi, M.; Ulivi, L.

    1997-01-01

    These proceedings represent papers presented at the 13th International Conference on Spectral Line Shapes which was held in Firenze,Italy from June 16-21, 1996. The topics covered a wide range of subjects emphasizing the physical processes associated with the formation of line profiles: high and low density plasma; atoms and molecules in strong laser fields, Dopple-free and ultra-fine spectroscopy; the line shapes generated by the interaction of neutrals, atoms and molecules, where the relavant quantities are single particle properties, and the interaction-induced spectroscopy. There were 131 papers presented at the conference, out of these, 6 have been abstracted for the Energy Science and Technology database

  13. Database of emission lines

    Science.gov (United States)

    Binette, L.; Ortiz, P.; Joguet, B.; Rola, C.

    1998-11-01

    A widely accessible data bank (available through Netscape) and consiting of all (or most) of the emission lines reported in the litterature is being built. It will comprise objects as diverse as HII regions, PN, AGN, HHO. One of its use will be to define/refine existing diagnostic emission line diagrams.

  14. APOBEC3DE Inhibits LINE-1 Retrotransposition by Interacting with ORF1p and Influencing LINE Reverse Transcriptase Activity.

    Directory of Open Access Journals (Sweden)

    Weizi Liang

    Full Text Available Human long interspersed elements 1 (LINE-1 or L1 is the only autonomous non-LTR retroelement in humans and has been associated with genome instability, inherited genetic diseases, and the development of cancer. Certain human APOBEC3 family proteins are known to have LINE-1 restriction activity. The mechanisms by which APOBEC3 affects LINE-1 retrotransposition are not all well characterized; here, we confirm that both A3B and A3DE have a strong ability to inhibit LINE-1 retrotransposition. A3DE interacts with LINE-1 ORF1p to target LINE-1 ribonucleoprotein particles in an RNA-dependent manner. Moreover, A3DE binds to LINE-1 RNA and ORF1 protein in cell culture system. Fluorescence microscopy demonstrated that A3DE co-localizes with ORF1p in cytoplasm. Furthermore, A3DE inhibits LINE-1 reverse transcriptase activity in LINE-1 ribonucleoprotein particles in a cytidine deaminase-independent manner. In contrast, A3B has less inhibitory effects on LINE-1 reverse transcriptase activity despite its strong inhibition of LINE-1 retrotransposition. This study demonstrates that different A3 proteins have been evolved to inhibit LINE-1 activity through distinct mechanisms.

  15. Building Bridges One Line at a Time

    Science.gov (United States)

    Grigsby, Cathy Murray

    2012-01-01

    In this article, first-grade students were taught the different kinds of lines that were part of the construction of various bridges--the curved lines of the arches of stone bridges, straight lines connecting the cables of a suspension bridge, vertical lines, horizontal lines, and so on. They gained practice in drawing structures and in fine brush…

  16. Along the line

    DEFF Research Database (Denmark)

    Dinesen, Cort Ross

    2011-01-01

    Embarking on a work of art constitutes a reduction of information – because we grasp the diversity and plurality of the manifestations we encounter by abstracting them and transforming them into manageable concepts; as we do when we draw contour lines on the landscape – they are imaginary...... and invisible but an abstraction essential for noting a difference or marking a place on a map. In the same way, a stroke in a sketch or a line in the sand is a manifestation of our ability to draw a boundary that both includes and excludes information. Where the line makes the birth of an idea visible......, it expresses through movement our tendency to mark a difference by drawing attention to and enclosing a whole series of relations that confront our preconceived notions. It is in the process of transformation in which we reduce the complexity of how we work, and rethink our ideas anew by refining the very same...

  17. Program of telluric lines monitoring

    Directory of Open Access Journals (Sweden)

    Vince I.

    2006-01-01

    Full Text Available A new observational program of telluric lines monitoring was introduced at Belgrade Astronomical Observatory. The ultimate goal of this program is to investigate the properties of Earth’s atmosphere through modeling the observed profiles of telluric lines. The program is intend to observe infrared molecular oxygen lines that were selected according to spectral sensitivity of the available CCD camera. In this paper we give the initial and the final selection criteria for spectral lines included in the program the description of equipment and procedures used for observations and reduction, a review of preliminary observational results with the estimated precision, and a short discussion on the comparison of the theoretical predictions and the measurements.

  18. Feasibility and early outcomes of laparoscopic plicated sleeve gastrectomy: a case-control study

    Directory of Open Access Journals (Sweden)

    Tomasz Rogula

    2016-01-01

    Full Text Available Introduction : Sleeve gastrectomy (SG continues to gain popularity as a viable weight loss procedure with well-documented outcomes and procedure-specific adverse effects. It has become increasingly indicated for the treatment of morbid obesity. Aim of the research : To compare a novel approach to SG, which aims to reduce SG-specific complications, to the standard SG procedure. Material and methods : Sixteen morbidly obese patients with a mean body mass index (BMI of 48.5 kg/m 2 ± SD who underwent the novel laparoscopic plicated sleeve gastrectomy (LPSG were retrospectively studied. The control group included 18 patients who underwent laparoscopic SG. Study and control groups were matched for BMI and gender. Study group patients underwent a partial SG with imbrication of the distal 2/3 of the staple line with 2 cm overlap and 3–4 cm of the pre-pyloric stomach. Control group SG patients had their staple line oversewn without plication. Outcomes at 3, 6 and 12 months were compared and analyzed. Results: There was no statistically significant difference in weight loss at 12 months between the LPSG and SG groups. Postoperative nausea was comparable between the two groups. No major complications were noted in either group. Conclusions: The LPSG is a modification of the standard SG which has comparable outcomes, safety and feasibility. It may lead to a decrease in unwanted complications such as sleeve stricture or obstruction. Further studies on long-term outcomes are needed to assess its value as a bariatric procedure.

  19. A multicenter study of routine versus selective intraoperative leak testing for sleeve gastrectomy.

    Science.gov (United States)

    Bingham, Jason; Kaufman, Jedediah; Hata, Kai; Dickerson, James; Beekley, Alec; Wisbach, Gordon; Swann, Jacob; Ahnfeldt, Eric; Hawkins, Devon; Choi, Yong; Lim, Robert; Martin, Matthew

    2017-09-01

    Staple line leaks after sleeve gastrectomy are dreaded complications. Many surgeons routinely perform an intraoperative leak test (IOLT) despite little evidence to validate the reliability, clinical benefit, and safety of this procedure. To determine the efficacy of IOLT and if routine use has any benefit over selective use. Eight teaching hospitals, including private, university, and military facilities. A multicenter, retrospective analysis over a 5-year period. The efficacy of the IOLT for identifying unsuspected staple line defects and for predicting postoperative leaks was evaluated. An anonymous survey was also collected reflecting surgeons' practices and beliefs regarding IOLT. From January 2010 through December 2014, 4284 patients underwent sleeve gastrectomy. Of these, 37 patients (.9%) developed a postoperative leak, and 2376 patients (55%) received an IOLT. Only 2 patients (0.08%) had a positive finding. Subsequently, 21 patients with a negative IOLT developed a leak. IOLT demonstrated a sensitivity of only 8.7%. There was a nonsignificant trend toward increased leak rates when an IOLT was performed versus when IOLT was not performed. Leak rates were not statistically different between centers that routinely perform IOLT versus those that selectively perform IOLT. Routine IOLT had very poor sensitivity and was negative in 91% of patients who later developed postoperative leaks. The use of IOLT was not associated with a decrease in the incidence of postoperative leaks, and routine IOLT had no benefit over selective leak testing. IOLT should not be used as a quality indicator or "best practice" for bariatric surgery. Published by Elsevier Inc.

  20. Sleeve gastrectomy severe complications: is it always a reasonable surgical option?

    Science.gov (United States)

    Moszkowicz, David; Arienzo, Roberto; Khettab, Idir; Rahmi, Gabriel; Zinzindohoué, Franck; Berger, Anne; Chevallier, Jean-Marc

    2013-05-01

    Laparoscopic sleeve gastrectomy (LSG) is widely adopted but exposes serious complications. A retrospective database analysis was done to study LSG staple line complications in a tertiary referral university center with surgical ICU experienced in treatment of morbid obesity and complications. Twenty-two consecutive patients were referred between January 2004 and February 2012 with postoperative gastric leak or stenosis after LSG. Interventions consisted in the control of intra-abdominal and general sepsis; restoration of staple line continuity or revision of LSG; nutritional support; treatment of associated complications. Main outcome measures concerned success rates of therapeutic strategies, morbidity and mortality rates, LOS, and time to cure. Thirteen patients (59 %) were referred after failure of reoperation (seven fistula repairs were attempted). Three patients received emergency surgery in our center with transorificial intubation and jejunostomy formation. An endoscopic stent was tried in nine patients but failed in 84.6 % of cases within 20 days (1-161). Seven patients (32 %) necessitated total gastrectomy within 217 days (0-1,915 days) for conservative treatment failure. Procedures under general anesthesia were required in 41 % of cases, organ failure was found in 55 % of cases, and central venous device infection in 40 %. Mortality rate was 4.5 % (n = 1). Patients with unfavorable evolution of LSG complications (death or additional gastrectomy) had more previous bariatric procedure (82 % vs. 18 %, p = 0.003). Median time to cure was 310 days (9-546 days). LSG exposes severe complications occurring in patients with benign condition. Endoscopic stents entail high failure rate. Total gastrectomy is required in one third of the cases.

  1. [The smile line, a literature search].

    Science.gov (United States)

    van der Geld, P A; van Waas, M A

    2003-09-01

    Beautiful teeth, visible when smiling, are in line with the present ideal of beauty. The display of teeth when smiling is determined by the smile line: the projection of the lower border of the upper lip on the maxillary teeth when smiling. On the basis of a literature search the determining methods of the smile line are discussed, demographic data of the position of the smile line are given, and factors of influence are examined. There is no unequivocal method for determining the position of the smile line. A rough distinction can be made between qualitative and (semi)-quantitative methods. The (semi)-quantitative methods have clear advantages for research purposes, but their reliability is unknown. It was demonstrated that among minimally 40% of subjects the maxillary gingiva was not visible when smiling. The mandibular gingiva was not visible when smiling among more than 90% of subjects. Furthermore, it appeared that among women the smile line was on average higher situated than among men and that it has not yet been proven that the smile line will be situated lower when growing older.

  2. A specialized bioengineering ion beam line

    International Nuclear Information System (INIS)

    Yu, L.D.; Sangyuenyongpipat, S.; Sriprom, C.; Thongleurm, C.; Suwanksum, R.; Tondee, N.; Prakrajang, K.; Vilaithong, T.; Brown, I.G.; Wiedemann, H.

    2007-01-01

    A specialized bioengineering ion beam line has recently been completed at Chiang Mai University to meet rapidly growing needs of research and application development in low-energy ion beam biotechnology. This beam line possesses special features: vertical main beam line, low-energy (30 keV) ion beams, double swerve of the beam, a fast pumped target chamber, and an in-situ atomic force microscope (AFM) system chamber. The whole beam line is situated in a bioclean environment, occupying two stories. The quality of the ion beam has been studied. It has proved that this beam line has significantly contributed to our research work on low-energy ion beam biotechnology

  3. Illustrative Line Styles for Flow Visualization

    NARCIS (Netherlands)

    Everts, Maarten H.; Bekker, Hendrik; Roerdink, Jos B. T. M.; Isenberg, Tobias

    2011-01-01

    We present a flexible illustrative line style model for the visualization of streamline data. Our model partitions view-oriented line strips into parallel bands whose basic visual properties can be controlled independently. We thus extend previous line stylization techniques specifically for

  4. Flow Visualization using Illustrative Line Styles

    NARCIS (Netherlands)

    Everts, Maarten H.; Bekker, Hendrik; Roerdink, Jos B. T. M.; Isenberg, Tobias; Bekker, Paulus

    2011-01-01

    We present a flexible illustrative line style model for the visualization of streamline data. Our model partitions view- oriented line strips into parallel bands whose basic visual properties can be controlled independently. We thus extend previous line stylization techniques specifically for

  5. Transgenic Cavendish bananas with resistance to Fusarium wilt tropical race 4.

    Science.gov (United States)

    Dale, James; James, Anthony; Paul, Jean-Yves; Khanna, Harjeet; Smith, Mark; Peraza-Echeverria, Santy; Garcia-Bastidas, Fernando; Kema, Gert; Waterhouse, Peter; Mengersen, Kerrie; Harding, Robert

    2017-11-14

    Banana (Musa spp.) is a staple food for more than 400 million people. Over 40% of world production and virtually all the export trade is based on Cavendish banana. However, Cavendish banana is under threat from a virulent fungus, Fusarium oxysporum f. sp. cubense tropical race 4 (TR4) for which no acceptable resistant replacement has been identified. Here we report the identification of transgenic Cavendish with resistance to TR4. In our 3-year field trial, two lines of transgenic Cavendish, one transformed with RGA2, a gene isolated from a TR4-resistant diploid banana, and the other with a nematode-derived gene, Ced9, remain disease free. Transgene expression in the RGA2 lines is strongly correlated with resistance. Endogenous RGA2 homologs are also present in Cavendish but are expressed tenfold lower than that in our most resistant transgenic line. The expression of these homologs can potentially be elevated through gene editing, to provide non-transgenic resistance.

  6. Computer-based mechanical design of overhead lines

    Science.gov (United States)

    Rusinaru, D.; Bratu, C.; Dinu, R. C.; Manescu, L. G.

    2016-02-01

    Beside the performance, the safety level according to the actual standards is a compulsory condition for distribution grids’ operation. Some of the measures leading to improvement of the overhead lines reliability ask for installations’ modernization. The constraints imposed to the new lines components refer to the technical aspects as thermal stress or voltage drop, and look for economic efficiency, too. The mechanical sizing of the overhead lines is after all an optimization problem. More precisely, the task in designing of the overhead line profile is to size poles, cross-arms and stays and locate poles along a line route so that the total costs of the line's structure to be minimized and the technical and safety constraints to be fulfilled.The authors present in this paper an application for the Computer-Based Mechanical Design of the Overhead Lines and the features of the corresponding Visual Basic program, adjusted to the distribution lines. The constraints of the optimization problem are adjusted to the existing weather and loading conditions of Romania. The outputs of the software application for mechanical design of overhead lines are: the list of components chosen for the line: poles, cross-arms, stays; the list of conductor tension and forces for each pole, cross-arm and stay for different weather conditions; the line profile drawings.The main features of the mechanical overhead lines design software are interactivity, local optimization function and high-level user-interface

  7. Veterans Crisis Line: 1-800-273-8255

    Science.gov (United States)

    Veterans Crisis Line Skip to Main Content SuicidePreventionLifeline.org Get Help Materials Get Involved Crisis Centers About Be There ... Line FAQs Veteran Suicide Welcome to the Veterans Crisis Line Website The Veterans Crisis Line connects Veterans ...

  8. Reddening and He i{sup ∗} λ 10830 Absorption Lines in Three Narrow-line Seyfert 1 Galaxies

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Shaohua; Zhou, Hongyan; Shi, Xiheng; Pan, Xiang; Ji, Tuo; Jiang, Peng; Wang, Shufen [Polar Research Institute of China, 451 Jinqiao Road, Shanghai, 200136 (China); Liu, Wenjuan [Key Laboratory for the Structure and Evolution of Celestial Objects, Yunnan Observatories, Chinese Academy of Sciences, Kunming, Yunnan 650011 (China); Jiang, Ning, E-mail: zhangshaohua@pric.org.cn, E-mail: zhouhongyan@pric.org.cn [Key Laboratory for Researches in Galaxies and Cosmology, Department of Astronomy, University of Sciences and Technology of China, Chinese Academy of Sciences, Hefei, Anhui, 230026 (China)

    2017-08-20

    We report the detection of heavy reddening and the He i* λ 10830 absorption lines at the active galactic nucleus (AGN) redshift in three narrow-line Seyfert 1 galaxies: SDSS J091848.61+211717.0, SDSS J111354.66+124439.0, and SDSS J122749.13+321458.9. They exhibit very red optical to near-infrared colors, narrow Balmer/Paschen broad emission lines and He i* λ 10830 absorption lines. The ultraviolet-optical-infrared nucleus continua are reddened by the SMC extinction law of E ( B − V ) ∼ 0.74, 1.17, and 1.24 mag for three objects, which are highly consistent with the values obtained from the broad-line Balmer decrements, but larger than those of narrow emission lines. The reddening analysis suggests that the extinction dust simultaneously obscures the accretion disk, the broad emission-line region, and the hot dust from the inner edge of the torus. It is possible that the dust obscuring the AGN structures is the dusty torus itself. Furthermore, the Cloudy analysis of the He i* λ 10830 absorption lines proposes the distance of the absorption materials to be the extend scale of the torus, which greatly increases probabilities of the obscure and absorption materials being the dusty torus.

  9. Magnetic pulse sharpener and delay-line

    International Nuclear Information System (INIS)

    Li Jin; Dai Guangsen; Xia Liansheng

    2002-01-01

    This paper describes a method to achieve short rise time pulse which has been delayed with a delay-line and magnetic pulse sharpener. A delay-line and two shock-lines are designed to carry pulsed signal with a maximum voltage magnitude up to 80 kV. A pulse of High voltage with arise time of 48 ns at a level of 0.1%-0.9% were achieved, and the attenuation in the line is very small

  10. Research on Line Patrol Strategy of 110kV Transmission Line after Lightning Strike

    Directory of Open Access Journals (Sweden)

    Li Mingjun

    2016-01-01

    Full Text Available Lightning faults occupy in the majority of instantaneous fault and reclosing can usually be successful, so power supply can be restored without immediate patrol in many cases. Firstly, this paper introduces the lightning fault positioning and identifying method. Then test electrical performance of insulators after lightning strike from 110kV lines. Data shows that lightning strike has little effect on the electric performance of insulator. Finally, illustrating disposal process of the 110 kV transmission line after lightning fault, certifying that the power supply reliability be ensured without line patrol.

  11. Infrared line intensities of chlorine monoxide

    Science.gov (United States)

    Kostiuk, T.; Faris, J. L.; Mumma, M. J.; Deming, D.; Hillman, J. J.

    1986-01-01

    Absolute infrared line intensities of several ClO lines in the rotational-vibrational (1-0) band were measured using infrared heterodyne spectroscopy near 12 microns. A measurement technique using combined ultraviolet absorption and infrared line measurements near 9.5 microns and 12 microns permitted an accurate determination of the column densities of O3 and ClO in the absorption cell and thus improved ClO line intensities. Results indicate ClO line and band intensities approximately 2.4 times lower than previous experimental results. Effects of possible failure of local thermodynamic equilibrium conditions in the absorption cell and the implication of the results for stratospheric ClO measurements in the infrared are discussed.

  12. Plasma line observations in the auroral oval

    International Nuclear Information System (INIS)

    Valladares, C.E.; Kelley, M.C.; Vickrey, J.F.

    1988-01-01

    We report here a series of experiments conducted at the Sondre Stromfjord incoherent scatter radar, aimed at detected enhanced plasma lines associated with midnight sector auroral arcs. Using different receivers, we detected both ion and plasma lines simultaneously. The plasma line signal was recorded with the use of a filter bank of eight frequencies. Plasma lines were found to originate mainly from the topside of the particle-produced E layer. The enhanced plasma lines are sometimes a factor of 100 times larger than the thermal level. Our data show a rapid decay of the plasma lines, however. In some cases, only a 30-s integration time was needed in order to unambiguously detect both upshifted and downshifted lines. The level of the plasma lines reaches values of, for the larger cases, up to 40 0 K above the noise temperature. These are considerably higher than results from prior auroral zone plasma line experiments. In situ observations of enhanced plasma waves in this same region are reported in a companion paper. copyright American Geophysical Union 1988

  13. Asymmetries of the solar Ca II lines

    International Nuclear Information System (INIS)

    Heasley, J.N.

    1975-01-01

    A theoretical study of the influence of propagating acoustic pulses in the solar chromosphere upon the line profiles of the Ca II resonance and infrared triplet lines has been made. The major objective has been to explain the observed asymmetries seen in the cores of the H and K lines and to predict the temporal behavior of the infrared lines caused by passing acoustic or shock pulses. The velocities in the pulses, calculated from weak shock theory, have been included consistently in the non-LTE calculations. The results of the calculations show that these lines are very sensitive to perturbations in the background atmosphere caused by the pulses. Only minor changes in the line shapes result from including the velocities consistently in the line source function calculations. The qualitative changes in the line profiles vary markedly with the strength of the shock pulses. The observed differences in the K line profiles seen on the quiet Sun can be explained in terms of a spectrum of pulses with different wavelengths and initial amplitudes in the photosphere. (Auth.)

  14. Combining prior day contours to improve automated prostate segmentation

    International Nuclear Information System (INIS)

    Godley, Andrew; Sheplan Olsen, Lawrence J.; Stephans, Kevin; Zhao Anzi

    2013-01-01

    Purpose: To improve the accuracy of automatically segmented prostate, rectum, and bladder contours required for online adaptive therapy. The contouring accuracy on the current image guidance [image guided radiation therapy (IGRT)] scan is improved by combining contours from earlier IGRT scans via the simultaneous truth and performance level estimation (STAPLE) algorithm. Methods: Six IGRT prostate patients treated with daily kilo-voltage (kV) cone-beam CT (CBCT) had their original plan CT and nine CBCTs contoured by the same physician. Three types of automated contours were produced for analysis. (1) Plan: By deformably registering the plan CT to each CBCT and then using the resulting deformation field to morph the plan contours to match the CBCT anatomy. (2) Previous: The contour set drawn by the physician on the previous day CBCT is similarly deformed to match the current CBCT anatomy. (3) STAPLE: The contours drawn by the physician, on each prior CBCT and the plan CT, are deformed to match the CBCT anatomy to produce multiple contour sets. These sets are combined using the STAPLE algorithm into one optimal set. Results: Compared to plan and previous, STAPLE improved the average Dice's coefficient (DC) with the original physician drawn CBCT contours to a DC as follows: Bladder: 0.81 ± 0.13, 0.91 ± 0.06, and 0.92 ± 0.06; Prostate: 0.75 ± 0.08, 0.82 ± 0.05, and 0.84 ± 0.05; and Rectum: 0.79 ± 0.06, 0.81 ± 0.06, and 0.85 ± 0.04, respectively. The STAPLE results are within intraobserver consistency, determined by the physician blindly recontouring a subset of CBCTs. Comparing plans recalculated using the physician and STAPLE contours showed an average disagreement less than 1% for prostate D98 and mean dose, and 5% and 3% for bladder and rectum mean dose, respectively. One scan takes an average of 19 s to contour. Using five scans plus STAPLE takes less than 110 s on a 288 core graphics processor unit. Conclusions: Combining the plan and all prior days via

  15. Simultaneous influence of Stark effect and excessive line broadening on the Hα line

    Science.gov (United States)

    Cvetanović, Nikola; Ivković, Saša S.; Obradović, Bratislav M.; Kuraica, Milorad M.

    2017-12-01

    The aim of this paper is to study the combined influence of the Stark effect and the excessive Doppler broadening on the Balmer alpha line in hydrogen discharges. Since this line is a good candidate for measuring electric field in various types of discharges with different gas compositions, a simple method for field measurement based on polarization spectroscopy is developed, that includes all the excitation mechanisms. To simultaneously test the flexibility of the fitting procedure and investigate the excessive broadening, we applied the fitting procedure on line profiles obtained at a range of conditions from two different discharges. The range of pressures and voltages was examined in an abnormal glow and in dielectric barrier discharge operating with hydrogen gas. The model fitting function was able to respond and follow the change in the line profile caused by the change of conditions. This procedure can therefore be recommended for electric field measurement. Contribution to the "Topical Issue: Physics of Ionized Gases (SPIG 2016)", edited by Goran Poparic, Bratislav Obradovic, Dragana Maric and Aleksandar Milosavljevic.

  16. Eccentric vision : adverse interactions between line segments

    NARCIS (Netherlands)

    Andriessen, J.J.; Bouma, H.

    1976-01-01

    The paper deals with adverse interactions between line stimuli ineccentric vision. Bothcontrast thresholdandjust noticeable difference of slanthave been measured for a test line as a function of the distance from a number of surrounding lines. Test lines were either parallel or perpendicular to the

  17. Polarization of Coronal Forbidden Lines

    Energy Technology Data Exchange (ETDEWEB)

    Li, Hao; Qu, Zhongquan [Yunnan Observatories, Chinese Academy of Sciences, Kunming, Yunnan 650011 (China); Landi Degl’Innocenti, Egidio, E-mail: sayahoro@ynao.ac.cn [Dipartimento di Astronomia e Scienza dello Spazio, Università di Firenze, Largo E. Fermi 2, I-50125 Firenze (Italy)

    2017-03-20

    Since the magnetic field is responsible for most manifestations of solar activity, one of the most challenging problems in solar physics is the diagnostics of solar magnetic fields, particularly in the outer atmosphere. To this end, it is important to develop rigorous diagnostic tools to interpret polarimetric observations in suitable spectral lines. This paper is devoted to analyzing the diagnostic content of linear polarization imaging observations in coronal forbidden lines. Although this technique is restricted to off-limb observations, it represents a significant tool to diagnose the magnetic field structure in the solar corona, where the magnetic field is intrinsically weak and still poorly known. We adopt the quantum theory of polarized line formation developed in the framework of the density matrix formalism, and synthesize images of the emergent linear polarization signal in coronal forbidden lines using potential-field source-surface magnetic field models. The influence of electronic collisions, active regions, and Thomson scattering on the linear polarization of coronal forbidden lines is also examined. It is found that active regions and Thomson scattering are capable of conspicuously influencing the orientation of the linear polarization. These effects have to be carefully taken into account to increase the accuracy of the field diagnostics. We also found that linear polarization observation in suitable lines can give valuable information on the long-term evolution of the magnetic field in the solar corona.

  18. service line analytics in the new era.

    Science.gov (United States)

    Spence, Jay; Seargeant, Dan

    2015-08-01

    To succeed under the value-based business model, hospitals and health systems require effective service line analytics that combine inpatient and outpatient data and that incorporate quality metrics for evaluating clinical operations. When developing a framework for collection, analysis, and dissemination of service line data, healthcare organizations should focus on five key aspects of effective service line analytics: Updated service line definitions. Ability to analyze and trend service line net patient revenues by payment source. Access to accurate service line cost information across multiple dimensions with drill-through capabilities. Ability to redesign key reports based on changing requirements. Clear assignment of accountability.

  19. Eliminating harmonics in line to line voltage using genetic algorithm using multilevel inverter

    Energy Technology Data Exchange (ETDEWEB)

    Gunasekaran, R. [Excel College of Engineering and Technology, Komarapalayam (India). Electrical and Electronics Engineering; Karthikeyan, C. [K.S. Rangasamy College of Engineering, Tamil Nadu (India). Electrical and Electronics Engineering

    2017-04-15

    In this project the total harmonic distortion (THD) minimization of the multilevel inverters output voltage is discussed. The approach in reducing harmonics contents in inverters output voltage is THD elimination. The switching angles are varied with the fundamental frequency so the output THD is minimized. In three phase applications, the line voltage harmonics are of the main concern from the load point of view. Using a genetic algorithm, a THD minimization process is directly applied to the line to line voltage of the inverter. Genetic (GA) algorithm allows the determination of the optimized parameters and consequently an optimal operating point of the circuit and a wide pass band with a unity gain is obtained.

  20. Isoeffect lines using TDF and CRE concepts

    International Nuclear Information System (INIS)

    Supe, S.J.; Sasane, J.B.; Gupta, M.K.; Supe, D.S.

    1979-01-01

    In most of the radiotherapy centres the treatment planning is based on isodose lines. Isoeffect lines are also being drawn based on the concepts of TDFs and CREs. A study has been made of whether the isoeffect lines based on the concepts of TDFs, CRes and the physical isodose lines are identical in all the treatment situations. Isoeffects lines for a few treatment schedules involving treatment of carcinoma of the bladder, treatment of cancer of the uterine cervix by combined intracavitary and external beam therapies and intracavitary therapy alone have been obtained and compared. The effect of treatment mode on the isoeffect lines has also been studied. It was found that the isodose curves and the isoeffect lines using the TDF and CRE concepts were not identical in all situations. Therefore, the ultimate treatment plans based on these isoeffect lines will not be exactly the same. The dependence of the isoeffect lines with the variation of the exponents of time and number of fractions used in the empirical relationship for NSD have also been investigated. Clinical trials have been initiated in the case of cancer of the bladder and cervix uterus based on the isodose curves and isoeffect lines using CRE and TDF concepts. (author)

  1. 2008 TIGER/Line Nationwide Dataset

    Data.gov (United States)

    California Natural Resource Agency — This dataset contains a nationwide build of the 2008 TIGER/Line datasets from the US Census Bureau downloaded in April 2009. The TIGER/Line Shapefiles are an extract...

  2. Optical Variability of Narrow-line and Broad-line Seyfert 1 Galaxies

    Energy Technology Data Exchange (ETDEWEB)

    Rakshit, Suvendu; Stalin, C. S., E-mail: suvenduat@gmail.com [Indian Institute of Astrophysics, Block II, Koramangala, Bangalore-560034 (India)

    2017-06-20

    We studied the optical variability (OV) of a large sample of narrow-line Seyfert 1 (NLSy1) and broad-line Seyfert 1 (BLSy1) galaxies with z < 0.8 to investigate any differences in their OV properties. Using archival optical V -band light curves from the Catalina Real Time Transient Survey that span 5–9 years and modeling them using damped random walk, we estimated the amplitude of variability. We found that NLSy1 galaxies as a class show lower amplitude of variability than their broad-line counterparts. In the sample of both NLSy1 and BLSy1 galaxies, radio-loud sources are found to have higher variability amplitude than radio-quiet sources. Considering only sources that are detected in the X-ray band, NLSy1 galaxies are less optically variable than BLSy1 galaxies. The amplitude of variability in the sample of both NLSy1 and BLSy1 galaxies is found to be anti-correlated with Fe ii strength but correlated with the width of the H β line. The well-known anti-correlation of variability–luminosity and the variability–Eddington ratio is present in our data. Among the radio-loud sample, variability amplitude is found to be correlated with radio-loudness and radio-power, suggesting that jets also play an important role in the OV in radio-loud objects, in addition to the Eddington ratio, which is the main driving factor of OV in radio-quiet sources.

  3. An Asian poverty line? Issues and options

    OpenAIRE

    Klasen, Stephan

    2016-01-01

    Given Asia's record of rapid economic growth and the conceptual and empirical problems of the current international income poverty line ('dollar-a-day'), this paper discusses whether there is merit to develop an Asia-specific poverty line that addresses some of the shortcomings of the dollar-a-day line and additionally considers Asia's particular economic situation. We consider various ways of creating an Asia-specific poverty line, including an Asia-specific international income poverty line...

  4. GARLIC - A general purpose atmospheric radiative transfer line-by-line infrared-microwave code: Implementation and evaluation

    Science.gov (United States)

    Schreier, Franz; Gimeno García, Sebastián; Hedelt, Pascal; Hess, Michael; Mendrok, Jana; Vasquez, Mayte; Xu, Jian

    2014-04-01

    A suite of programs for high resolution infrared-microwave atmospheric radiative transfer modeling has been developed with emphasis on efficient and reliable numerical algorithms and a modular approach appropriate for simulation and/or retrieval in a variety of applications. The Generic Atmospheric Radiation Line-by-line Infrared Code - GARLIC - is suitable for arbitrary observation geometry, instrumental field-of-view, and line shape. The core of GARLIC's subroutines constitutes the basis of forward models used to implement inversion codes to retrieve atmospheric state parameters from limb and nadir sounding instruments. This paper briefly introduces the physical and mathematical basics of GARLIC and its descendants and continues with an in-depth presentation of various implementation aspects: An optimized Voigt function algorithm combined with a two-grid approach is used to accelerate the line-by-line modeling of molecular cross sections; various quadrature methods are implemented to evaluate the Schwarzschild and Beer integrals; and Jacobians, i.e. derivatives with respect to the unknowns of the atmospheric inverse problem, are implemented by means of automatic differentiation. For an assessment of GARLIC's performance, a comparison of the quadrature methods for solution of the path integral is provided. Verification and validation are demonstrated using intercomparisons with other line-by-line codes and comparisons of synthetic spectra with spectra observed on Earth and from Venus.

  5. Design of LEIR Transfer Lines

    CERN Document Server

    Carli, Ch; Hemery, J-Y

    2002-01-01

    The LEIR transfer lines are designed to transport the ion beam from the Linac 3 to LEIR and, after accumulation and acceleration from LEIR to the PS. A part of the transfer line is used for both, injection and extraction. Thus, it is natural to design injection and extraction optics in common. Beside optics constraints, the geometry of the existing machines (Linac 3, LEIR and PS) and transfer tunnels have to be respected. A new proposal for the LEIR transfer lines is presented.

  6. Conceptual design for transmission line inspection robot

    International Nuclear Information System (INIS)

    Jalal, M F Abdul; Sahari, K S Mohamed; Anuar, A; Arshad, A D Mohd; Idris, M S

    2013-01-01

    Power transmission line is used for power distribution purposes due to their cost effective measure compared to underlying cable. However, prolonged exposure to natural weather may cause fatigue stress to the lines as well as induce material failure. Therefore, periodical line inspection is considered uttermost important as a preventive measure to avoid power outage. However, transmission line inspection has always been a high risk and expensive work. Hazardous works that may harm operator as well as routine that requires precise handling can be performed by robots. Various types of robots have been designed and developed for line inspection but only perform well on a straight and continuous line. As these robots encounter an obstacle during the inspection, then the real problem in terms of robot stability and smooth operation arises. In this paper, conceptual design and evaluation for transmission line inspection robot is presented. The inspection robot mobile robot must be able to bypass or avoid obstacles as it travels along the power transmission line.

  7. Iron forbidden lines in tokamak discharges

    International Nuclear Information System (INIS)

    Suckewer, S.; Hinnov, E.

    1979-03-01

    Several spectrum lines from forbidden transitions in the ground configurations of highly ionized atoms have been observed in the PLT tokamak discharges. Such lines allow localized observations, in the high-temperature regions of the plasma, of ion-temperatures, plasma motions, and spatial distributions of ions. Measured absolute intensities of the forbidden lines have been compared with simultaneous observations of the ion resonance lines and with model calculations in order to deduce the mechanism of level populaions by means of electron collisions and radiative transitions

  8. Iron forbidden lines in tokamak discharges

    Energy Technology Data Exchange (ETDEWEB)

    Suckewer, S.; Hinnov, E.

    1979-03-01

    Several spectrum lines from forbidden transitions in the ground configurations of highly ionized atoms have been observed in the PLT tokamak discharges. Such lines allow localized observations, in the high-temperature regions of the plasma, of ion-temperatures, plasma motions, and spatial distributions of ions. Measured absolute intensities of the forbidden lines have been compared with simultaneous observations of the ion resonance lines and with model calculations in order to deduce the mechanism of level populaions by means of electron collisions and radiative transitions.

  9. UV line emission of symbiotic stars

    International Nuclear Information System (INIS)

    Nussbaumer, H.

    1982-01-01

    General characteristics of emission line spectra from symbiotic stars are outlined. Data from some special line ratios in the 1000 A - 3000 A range, and others connecting the visual and the far UV lines are presented, and their application to symbiotic stars is discussed. Integrated fractional abundances for ions easily observed in the far UV are given to facilitate abundance determinations for nebular conditions. It is found that the physical conditions of the regions emitting the emission line spectra differ considerably among different symbiotic stars. (Auth.)

  10. Line radiative transfer and statistical equilibrium*

    Directory of Open Access Journals (Sweden)

    Kamp Inga

    2015-01-01

    Full Text Available Atomic and molecular line emission from protoplanetary disks contains key information of their detailed physical and chemical structures. To unravel those structures, we need to understand line radiative transfer in dusty media and the statistical equilibrium, especially of molecules. I describe here the basic principles of statistical equilibrium and illustrate them through the two-level atom. In a second part, the fundamentals of line radiative transfer are introduced along with the various broadening mechanisms. I explain general solution methods with their drawbacks and also specific difficulties encountered in solving the line radiative transfer equation in disks (e.g. velocity gradients. I am closing with a few special cases of line emission from disks: Radiative pumping, masers and resonance scattering.

  11. Composite Materials in Overhead Lines

    DEFF Research Database (Denmark)

    Sørensen, Thomas Kjærsgaard; Holbøll, Joachim

    2009-01-01

    towers and recently conductors based on composite materials are available at transmission levels. In this paper it is investigated which composite based solutions are available in connection with complete overhead line systems including insulators, towers and conductors. The components are reviewed......The use of composite materials, e.g. fibreglass materials, in overhead transmission line systems is nothing new. Composite based insulators have been applied to transmission lines for over 30 years, mainly as suspension and post insulators and often as an option for special applications. Also...... with respect to solved and persisting known failures/problems of both mechanical and electrical nature. Major challenges related to extensive use of composite materials in an overhead line system are identified, as are possible benefits - both when using standard as well as customised composite components, e...

  12. WEAK LINE QUASARS AT HIGH REDSHIFT: EXTREMELY HIGH ACCRETION RATES OR ANEMIC BROAD-LINE REGIONS?

    International Nuclear Information System (INIS)

    Shemmer, Ohad; Trakhtenbrot, Benny; Netzer, Hagai; Anderson, Scott F.; Brandt, W. N.; Schneider, Donald P.; Diamond-Stanic, Aleksandar M.; Fan Xiaohui; Lira, Paulina; Plotkin, Richard M.; Richards, Gordon T.; Strauss, Michael A.

    2010-01-01

    We present Gemini-North K-band spectra of two representative members of the class of high-redshift quasars with exceptionally weak rest-frame ultraviolet emission lines (WLQs), SDSS J114153.34+021924.3 at z = 3.55 and SDSS J123743.08+630144.9 at z = 3.49. In both sources, we detect an unusually weak broad Hβ line and place tight upper limits on the strengths of their [O III] lines. Virial, Hβ-based black hole mass determinations indicate normalized accretion rates of L/L Edd =0.4 for these sources, which is well within the range observed for typical quasars with similar luminosities and redshifts. We also present high-quality XMM-Newton imaging spectroscopy of SDSS J114153.34+021924.3 and find a hard-X-ray photon index of Γ = 1.91 +0.24 -0.22 , which supports the virial L/L Edd determination in this source. Our results suggest that the weakness of the broad emission lines in WLQs is not a consequence of an extreme continuum-emission source but instead due to abnormal broad emission line region properties.

  13. Applying TPM on Production Line of Huanwei

    Directory of Open Access Journals (Sweden)

    Zhai Yunkai

    2017-01-01

    The study based on the study and analysis of the TPM theory, based on my practice in the SMT2 production line of Victoria Electronics of Huanwei. Then it studied the promotion and implementation steps of TPM on SMT2 line. And it also introduced the improvement instance of SMT2 line. By contrasting the utilization of equipment on SMT2 line before and after the comprehensive of TPM, the necessity of implementing TPM is derived. For how to apply TPM on the production lines, and how to improve equipment comprehensive utilization, finish the order on time, provide high quality products to our customers, these are the main part of production line equipment management work. This article provides the reference for how to promote TPM on other production lines.

  14. Atmospheric structure deduced from disturbed line profiles application to Ca II lines

    International Nuclear Information System (INIS)

    Mein, N.; Mein, P.; Malherbe, J.-M.; Dame, L.; Dumont, S.; CNRS, Laboratoire de Physique Stellaire et Planetaire, Verrieres-le-Buisson, France; College de France, Paris)

    1985-01-01

    A new method is described in order to derive physical quantities (temperature, pressure, radial velocities) from the observation of disturbed line profiles. A method of Fourier analysis is suggested with double profiles and a nonlinear expansion of the coefficient of the Fourier terms. An application to a sequence of H-Ca II lines is attempted. The method is a powerful tool allowing for the simultaneous determination of at least four physical quantities. 9 references

  15. 40 CFR Table 12 to Subpart Wwww of... - Data Requirements for New and Existing Continuous Lamination Lines and Continuous Casting Lines...

    Science.gov (United States)

    2010-07-01

    ... Continuous Lamination Lines and Continuous Casting Lines Complying With a Lbs/Ton Organic HAP Emissions Limit... Requirements for New and Existing Continuous Lamination Lines and Continuous Casting Lines Complying With a Lbs... with a lbs/ton organic HAP emissions limit for continuous lamination lines and continuous casting lines...

  16. X-ray spectral line coincidences between fluorine VIII (and IX) and transition metal lines

    International Nuclear Information System (INIS)

    Charatis, G.; Rockett, P.D.; Burkhalter, P.G.

    1983-01-01

    X-ray spectroscopy was performed in the 12 to 15 A region, recording L-shell lines from selected laser-irradiated transition metals. Line coincidences and near coincidences were identified between Fe, Cr, Mn, and Ni L-spectra, and F VIII and F IX K-shell lines. Wavelengths were determined to accuracies of 1 to 3 mA and will be utilized in selecting potential pumping candidates in future x-ray lasing schemes. High-resolution x-ray spectra were collected under controlled illumination and target conditions using 1.05 μm and 0.527 μm laser excitation with the KMS CHROMA laser

  17. Multiple gamma lines from semi-annihilation

    International Nuclear Information System (INIS)

    D'Eramo, Francesco; McCullough, Matthew; Thaler, Jesse

    2013-01-01

    Hints in the Fermi data for a 130 GeV gamma line from the galactic center have ignited interest in potential gamma line signatures of dark matter. Explanations of this line based on dark matter annihilation face a parametric tension since they often rely on large enhancements of loop-suppressed cross sections. In this paper, we pursue an alternative possibility that dark matter gamma lines could arise from ''semi-annihilation'' among multiple dark sector states. The semi-annihilation reaction ψ i ψ j → ψ k γ with a single final state photon is typically enhanced relative to ordinary annihilation ψ i ψ-bar i → γγ into photon pairs. Semi-annihilation allows for a wide range of dark matter masses compared to the fixed mass value required by annihilation, opening the possibility to explain potential dark matter signatures at higher energies. The most striking prediction of semi-annihilation is the presence of multiple gamma lines, with as many as order N 3 lines possible for N dark sector states, allowing for dark sector spectroscopy. A smoking gun signature arises in the simplest case of degenerate dark matter, where a strong semi-annihilation line at 130 GeV would be accompanied by a weaker annihilation line at 173 GeV. As a proof of principle, we construct two explicit models of dark matter semi-annihilation, one based on non-Abelian vector dark matter and the other based on retrofitting Rayleigh dark matter

  18. 33 CFR 183.562 - Metallic fuel lines.

    Science.gov (United States)

    2010-07-01

    ...) BOATING SAFETY BOATS AND ASSOCIATED EQUIPMENT Fuel Systems Manufacturer Requirements § 183.562 Metallic fuel lines. (a) Each metallic fuel line that is mounted to the boat structure must be connected to the engine by a flexible fuel line. (b) Each metallic fuel line must be attached to the boat's structure...

  19. Managing first-line failure.

    Science.gov (United States)

    Cooper, David A

    2014-01-01

    WHO standard of care for failure of a first regimen, usually 2N(t)RTI's and an NNRTI, consists of a ritonavir-boosted protease inhibitor with a change in N(t)RTI's. Until recently, there was no evidence to support these recommendations which were based on expert opinion. Two large randomized clinical trials, SECOND LINE and EARNEST both showed excellent response rates (>80%) for the WHO standard of care and indicated that a novel regimen of a boosted protease inhibitor with an integrase inhibitor had equal efficacy with no difference in toxicity. In EARNEST, a third arm consisting of induction with the combined protease and integrase inhibitor followed by protease inhibitor monotherapy maintenance was inferior and led to substantial (20%) protease inhibitor resistance. These studies confirm the validity of the current recommendations of WHO and point to a novel public health approach of using two new classes for second line when standard first-line therapy has failed, which avoids resistance genotyping. Notwithstanding, adherence must be stressed in those failing first-line treatments. Protease inhibitor monotherapy is not suitable for a public health approach in low- and middle-income countries.

  20. Employment of the 307th Medical Battalion (Airborne) in Operations Desert Shield and Desert Storm: A Personal Experience Monograph

    Science.gov (United States)

    1992-05-08

    rations were the primary ration, augmented with local foodstuffs and always plentiful supplies of sodas, juices and fresh fruit. Despite some media ... mushroomed throughout the ’heater. The XVIII Airborne Corps Chief of Staff issued a scathing message to all CONUS, COMMZ and theater medical elements...Large 12s ex 4 ..... Staple i-I S5 Medium 12’s BX 1 --- Staple~ PI 1 Larqe 12S BDA I1 Staple P1 35) M,.d iu m 125 BX 2 379 -007th Medical Battalion

  1. A Product Line Enhanced Unified Process

    DEFF Research Database (Denmark)

    Zhang, Weishan; Kunz, Thomas

    2006-01-01

    The Unified Process facilitates reuse for a single system, but falls short handling multiple similar products. In this paper we present an enhanced Unified Process, called UPEPL, integrating the product line technology in order to alleviate this problem. In UPEPL, the product line related activit...... activities are added and could be conducted side by side with other classical UP activities. In this way both the advantages of Unified Process and software product lines could co-exist in UPEPL. We show how to use UPEPL with an industrial mobile device product line in our case study....

  2. Earthquake free design of pipe lines

    International Nuclear Information System (INIS)

    Kurihara, Chizuko; Sakurai, Akio

    1974-01-01

    Long structures such as cooling sea water pipe lines of nuclear power plants have a wide range of extent along the ground surface, and are incurred by not only the inertia forces but also forces due to ground deformations or the seismic wave propagation during earthquakes. Since previous reports indicated the earthquake free design of underground pipe lines, it is discussed in this report on behaviors of pipe lines on the ground during earthquakes and is proposed the aseismic design of pipe lines considering the effects of both inertia forces and ground deformations. (author)

  3. ALFA: an automated line fitting algorithm

    Science.gov (United States)

    Wesson, R.

    2016-03-01

    I present the automated line fitting algorithm, ALFA, a new code which can fit emission line spectra of arbitrary wavelength coverage and resolution, fully automatically. In contrast to traditional emission line fitting methods which require the identification of spectral features suspected to be emission lines, ALFA instead uses a list of lines which are expected to be present to construct a synthetic spectrum. The parameters used to construct the synthetic spectrum are optimized by means of a genetic algorithm. Uncertainties are estimated using the noise structure of the residuals. An emission line spectrum containing several hundred lines can be fitted in a few seconds using a single processor of a typical contemporary desktop or laptop PC. I show that the results are in excellent agreement with those measured manually for a number of spectra. Where discrepancies exist, the manually measured fluxes are found to be less accurate than those returned by ALFA. Together with the code NEAT, ALFA provides a powerful way to rapidly extract physical information from observations, an increasingly vital function in the era of highly multiplexed spectroscopy. The two codes can deliver a reliable and comprehensive analysis of very large data sets in a few hours with little or no user interaction.

  4. Ground-based transmission line conductor motion sensor

    International Nuclear Information System (INIS)

    Jacobs, M.L.; Milano, U.

    1988-01-01

    A ground-based-conductor motion-sensing apparatus is provided for remotely sensing movement of electric-power transmission lines, particularly as would occur during the wind-induced condition known as galloping. The apparatus is comprised of a motion sensor and signal-generating means which are placed underneath a transmission line and will sense changes in the electric field around the line due to excessive line motion. The detector then signals a remote station when a conditioning of galloping is sensed. The apparatus of the present invention is advantageous over the line-mounted sensors of the prior art in that it is easier and less hazardous to install. The system can also be modified so that a signal will only be given when particular conditions, such as specific temperature range, large-amplitude line motion, or excessive duration of the line motion, are occurring

  5. Sprayed concrete linings

    Energy Technology Data Exchange (ETDEWEB)

    Hindle, D.

    1999-12-01

    Sprayed concrete, or shotcrete, was invented in the 1920s for preserving dinosaur skeletons and was used underground initially in coalmines for the preservation and fine proofing of timber supports. Its use as a support lining in rock tunnelling was developed in the 1950s and 60s. The article surveys equipment available from major manufacturers and suppliers of concrete spraying equipment (Aliva, Cifa, GIA, Industri, Ingersoll Rand, etc.), specialist cement and additive manufacturers (Castle, Cement, Moria Carbotech). manufacturers of lattice girders and fibre reinforcement, and manufacturers of instrumentation for tunnel linings. 5 tabs., 9 photos.

  6. Capital Improvements Business Line

    Science.gov (United States)

    2012-08-08

    NAVFAC Southwest Dan Waid Program & Business Mgmt NAVFAC SW Capital Improvements Business Line NAVFAC SW 8 August 2012 1 Report...REPORT TYPE 3. DATES COVERED 00-00-2012 to 00-00-2012 4. TITLE AND SUBTITLE Capital Improvements Business Line 5a. CONTRACT NUMBER 5b. GRANT...AVAILABILITY STATEMENT Approved for public release; distribution unlimited 13. SUPPLEMENTARY NOTES Presented at the 2012 Navy Gold Coast Small Business

  7. Cavity lining after excavating caries lesions

    DEFF Research Database (Denmark)

    Schwendicke, Falk; Göstemeyer, Gerd; Gluud, Christian

    2015-01-01

    OBJECTIVES: After removal of dentin caries lesions, cavity lining has been advocated. Non-clinical data support this approach, but clinical data are sparse and ambiguous. We aimed at evaluating the benefits and harms of cavity lining using meta-analysis and Trial Sequential Analysis. DATA: We...... included randomized clinical trials comparing restorations without versus with cavity lining for treating primary caries lesions. Only trials reporting failure (defined as need to re-retreat) after ≥1 year follow-up were included. Trial selection, data extraction, and risk of bias assessment were conducted....... STUDY SELECTION: From 128 studies, three randomized trials (89/130 patients or teeth), all treating primary teeth, were included. The trials had high risk of bias. All trials compared no lining versus calcium hydroxide lining after selective caries removal followed by adhesive restoration. Follow...

  8. New Stokes' line in WKB theory

    International Nuclear Information System (INIS)

    Berk, H.L.; Nevins, W.M.; Roberts, K.V.

    1982-01-01

    The WKB theory for differential equations of arbitrary order or integral equations in one dimension is investigated. The rules previously stated for the construction of Stokes' lines for Nth-order differential equations, N> or =3, or integral equations are found to be incomplete because these rules lead to asymptotic forms of the solutions that depend on path. This paradox is resolved by the demonstration that new Stokes' lines can arise when previously defined Stokes' lines cross. A new formulation of the WKB problem is given to justify the new Stokes' lines. With the new Stokes' lines, the asymptotic forms can be shown to be independent of path. In addition, the WKB eigenvalue problem is formulated, and the global dispersion relation is shown to be a functional of loop integrals of the action

  9. Multiple Lines of Evidence

    Energy Technology Data Exchange (ETDEWEB)

    Amidan, Brett G. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Venzin, Alexander M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Bramer, Lisa M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-06-03

    This paper discusses the process of identifying factors that influence the contamination level of a given decision area and then determining the likelihood that the area remains unacceptable. This process is referred to as lines of evidence. These lines of evidence then serve as inputs for the stratified compliance sampling (SCS) method, which requires a decision area to be divided into strata based upon contamination expectations. This is done in order to focus sampling efforts more within stratum where contamination is more likely and to use the domain knowledge about these likelihoods of the stratum remaining unacceptable to buy down the number of samples necessary, if possible. Two different building scenarios were considered as an example (see Table 3.1). SME expertise was elicited concerning four lines of evidence factors (see Table 3.2): 1) amount of contamination that was seen before decontamination, 2) post-decontamination air sampling information, 3) the applied decontaminant information, and 4) the surface material. Statistical experimental design and logistic regression modelling were used to help determine the likelihood that example stratum remained unacceptable for a given example scenario. The number of samples necessary for clearance was calculated by applying the SCS method to the example scenario, using the estimated likelihood of each stratum remaining unacceptable as was determined using the lines of evidence approach. The commonly used simple random sampling (SRS) method was also used to calculate the number of samples necessary for clearance for comparison purposes. The lines of evidence with SCS approach resulted in a 19% to 43% reduction in total number of samples necessary for clearance (see Table 3.6). The reduction depended upon the building scenario, as well as the level of percent clean criteria. A sensitivity analysis was also performed showing how changing the estimated likelihoods of stratum remaining unacceptable affect the number

  10. The relationship between method of anastomosis and anastomotic failure after right hemicolectomy and ileo-caecal resection: an international snapshot audit.

    Science.gov (United States)

    2017-03-06

    Anastomosis technique following right sided colonic resection is widely variable and may affect patient outcomes. This study aimed to assess the association between leak and anastomosis technique (stapled versus handsewn) METHODS: This was a prospective, multicentre, international audit including patients undergoing elective or emergency right hemicolectomy or ileo-caecal resection operations over a two-month period in early 2015. The primary outcome measure was the presence of anastomotic leak within 30 days of surgery, using a pre-specified definition. Mixed effects logistic regression models were used to assess the association between leak and anastomosis method, adjusting for patient, disease and operative cofactors, with centre included as a random effect variable. This study included 3208 patients, of whom 78.4% (n=2515) underwent surgery for malignancy and 11.7% (n=375) for Crohn's disease. An anastomosis was performed in 94.8% (n=3041) of patients, which was handsewn in 38.9% (n=1183) and stapled in 61.1% (n=1858) cases. Patients undergoing handsewn anastomosis were more likely to be emergency admissions (20.5% handsewn versus 12.9% stapled) and to undergo open surgery (54.7% versus 36.6%). The overall anastomotic leak rate was 8.1% (245/3041), which was similar following handsewn (7.4%) and stapled (8.5%) techniques (p=0.3). After adjustment for cofactors, the odds of a leak were higher for stapled anastomosis (adjusted odds ratio 1.43, 95% confidence interval 1.04-1.95, p=0.03). Despite being used in lower risk patients, stapled anastomosis was associated with an increased anastomotic leak rate in this observational study. Further research is needed to define patient groups in whom a stapled anastomosis is safe. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  11. Tubular lining material for pipelines having bends

    Energy Technology Data Exchange (ETDEWEB)

    Moringa, A.; Sakaguchi, Y.; Hyodo, M.; Yagi, I.

    1987-03-24

    A tubular lining material for pipelines having bends or curved portions comprises a tubular textile jacket made of warps and wefts woven in a tubular form overlaid with a coating of a flexible synthetic resin. It is applicable onto the inner surface of a pipeline having bends or curved portions in such manner that the tubular lining material with a binder onto the inner surface thereof is inserted into the pipeline and allowed to advance within the pipeline, with or without the aid of a leading rope-like elongated element, while turning the tubular lining material inside out under fluid pressure. In this manner the tubular lining material is applied onto the inner surface of the pipeline with the binder being interposed between the pipeline and the tubular lining material. The lining material is characterized in that a part of all of the warps are comprised of an elastic yarn around which, over the full length thereof, a synthetic fiber yarn or yarns have been left-and/or right-handedly coiled. This tubular lining material is particularly suitable for lining a pipeline having an inner diameter of 25-200 mm and a plurality of bends, such as gas service pipelines or house pipelines, without occurrence of wrinkles in the lining material in a bend.

  12. Interferometric measurement of lines shift in flames in connection with interpretation of lined absorption method in atomic absorption spectroscopy

    International Nuclear Information System (INIS)

    L'vov, B.V.; Polzik, L.K.; Katskov, D.A.; Kruglikova, L.P.

    1975-01-01

    This paper is concerned with interferometric measuring of the line shift in flames in the view of interpretation of absorption lines in the atomic absorption spectroscopy. The newly measured line shifts were compared to the known data on Lorentz broadening of the same lines obtained by methods free of the systematic errors. The resonant lines of the alkaline earth elements (Sr, Ca, Ba) were investigated. To reduce self-absorption in the flame the solutions with minimum concentrations of the elements were used. The computation scheme includes the spectrometer apparatus width and line broadening due to the self-absorption. Formulae are given for computing the values studied. Good agreement was observed between the computed and experimental results. Error analysis was performed. It was concluded that any line shifts in the hydrocarbons were correctly taken into an account in the absolute computations of absorption

  13. Line Emission and X-ray Line Polarization of Multiply Ionized Mo Ions

    Science.gov (United States)

    Petkov, E. E.; Safronova, A. S.; Kantsyrev, V. L.; Shlyaptseva, V. V.; Stafford, A.; Safronova, U. I.; Shrestha, I. K.; Schultz, K. A.; Childers, R.; Cooper, M. C.; Beiersdorfer, P.; Hell, N.; Brown, G. V.

    2016-10-01

    We present a comprehensive experimental and theoretical study of the line emission from multiply ionized Mo ions produced by two different sets of experiments: at LLNL EBIT and the pulsed power generator Zebra at UNR. Mo line emission and polarization measurements were accomplished at EBIT for the first time. In particular, benchmarking experiments at the LLNL EBIT with Mo ions produced at electron beam energies from 2.75 keV up to 15 keV allowed us to break down these very complicated spectra into spectra with only few ionization stages and to select processes that influence them as well as to measure line polarization. The EBIT data were recorded using the EBIT Calorimeter Spectrometer and a crystal spectrometer with a Ge crystal. X-ray Mo spectra and pinhole images were collected from Z-pinch plasmas produced from various wire loads. Non-LTE modeling, high-precision relativistic atomic and polarization data were used to analyze L-shell Mo spectra. The influence of different plasma processes including electron beams on Mo line radiation is summarized. This work was supported by NNSA under DOE Grant DE-NA0002954. Experiments at the NTF/UNR were funded in part by DE-NA0002075. Work at LLNL was performed under the auspices of the U.S. DOE under contract DE-AC52-07NA27344.

  14. Magnetization of topological line-node semimetals

    Science.gov (United States)

    Mikitik, G. P.; Sharlai, Yu. V.

    2018-02-01

    Using an approximate expression for the Landau levels of the electrons located near a nodal line of a topological line-node semimetal, we obtain formulas for the magnetization of this semimetal at an arbitrary shape of its line. It is also shown that the dependence of the chemical potential on the magnetic field can be strong in these materials, and this dependence can essentially influence the de Haas-van Alphen oscillations. The obtained results are applied to the rhombohedral graphite, which is one of the line-node semimetals. For this material, we find temperature and magnetic field dependencies of its magnetic susceptibility.

  15. SAF line powder operations

    International Nuclear Information System (INIS)

    Frederickson, J.R.; Horgos, R.M.

    1983-10-01

    An automated nuclear fuel fabrication line is being designed for installation in the Fuels and Materials Examination Facility (FMEF) near Richland, Washington. The fabrication line will consist of seven major process systems: Receiving and Powder Preparation; Powder Conditioning; Pressing and Boat Loading; Debinding, Sintering, and Property Adjustment; Boat Transport; Pellet Inspection and Finishing; and Pin Operations. Fuel powder processing through pellet pressing will be discussed in this paper

  16. Discovery of FDA-Approved Drugs that Promote Retinal Cell Survival or Regeneration

    Science.gov (United States)

    2015-10-01

    disturbing agent against microorganisms Y Secondary ARQiv screens are ongoing whereby the three most effective concentrations will be re-tested at a...91,976 Preparation/Characterization of Bioabsorbable, antibiotic-eluting sutures Our goal is to develop biodegradable , polymeric sutures of the...vehicle. R01HL127413 (Hanes/Suk) 04/01/15 – 02/28/19 0.6 calendar NIH/NHLBI $263,000 Biodegradable Mucus Penetrating DNA Nanoparticle for

  17. Laser cutting system in bridge fabricating line; Kyoryo seisaku line ni okeru laser no setsudan system

    Energy Technology Data Exchange (ETDEWEB)

    Kitaguchi, Y.; Yokotani, K. [Hitachi Zosen Corp., Osaka (Japan)

    1994-11-01

    This paper describes the laser cutting system established at a new advanced plant that was constructed by Hitachi Shipbuilding and Engineering Co., Ltd. in 1993. At the plant, the cutting line consists of four NC cutting lines: the plasma cutting machine, gas cutting machine, frame planer, and laser cutting machine. The laser cutting machine is used to cut complex shapes of relatively thin (6 - 16 mm) materials with high accuracy. The machine consists of a 3 kW CO2 laser oscillator mounted gantry type NC cutter and a slat conveyor of about 30 m long, with the maximum cutting width of 3.6 m. The NC cutting machine is provided with the automatic printing function using NC data, marking function, scheduled operation function, steel plate detector, and coordinate rotation function, etc. These functions enable unattended operation of the machine to cut multiple materials. This NC laser cutting line has the same performance data collection function for data during the operating time as other production lines. Therefore, the NC laser cutting line can be subjected to the realtime centralized control together with the other lines. All these technologies have provided high accuracy and efficiency for production as well as an environment in which many female operators can successfully work. 10 figs., 4 tabs.

  18. Estudo sobre a eficácia da aerostasia pulmonar, em modelo animal, utilizando diferentes tipos de suturas Study about the ability of the pulmonary aerostasia, in animal model, using differents parenchymal pulmonary types of the sutures

    Directory of Open Access Journals (Sweden)

    Darcy Ribeiro Pinto Filho

    2003-10-01

    pressure levels, varying from 10 cmH2O to 60 cmH2O. The presence of air leaks along the suture line was verified through the water seal maneuver. RESULTS: The mean intrabronchial pressure level needed to cause suture line air leaks for each type were: type 1 (n = 10: 29 cmH2O; type 2 (n = 10: 38.5 cmH2O; type 3 (n = 10: 44 cmH2O; and type 4 (n = 10: 51.4 cmH2O. The comparison between the mean intrabronchial pressure level of type 1 and of types 2 and 3 sutures was statistically significant, respectively: p = 0.04 and p = 0.01. However, the comparison between types 2, 3 and 4 did not show statistic significance (p > 0.05. CONCLUSIONS: The pulmonary suture covered by biologic glue demonstrated more resistance to incremental levels of intrabronchial pressure. Parenchymal pulmonary sutures using stapled suture exclusively or stapled with bovine pericardium or biologic glue demonstrated an increased ability to avoid air leaks if compared to absorbable sutures in a model of porcine lung with incremental levels of intrabronchial pressure. There were no differences between stapler exclusively or stapler and bovine pericardium or biologic glue.

  19. Marine line fish research programme

    CSIR Research Space (South Africa)

    SANCOR

    1979-04-01

    Full Text Available This report outlines the framework for a marine line fish programme under the aegis of the South African National Committee for Oceanographic Research (SANCOR). An attempt is made to assess the state of knowledge about South African marine line...

  20. Line-mode browser development days

    CERN Multimedia

    Anna Pantelia

    2013-01-01

    Twelve talented web developers have travelled to CERN from all over the world to recreate a piece of web history: the line-mode browser. See the line-mode browser simulator that they created here. Read more about the birth of the web here.

  1. Formation of extremely narrow metallic lines

    International Nuclear Information System (INIS)

    Harris, E.P.; Keyes, R.W.

    1979-01-01

    A method for forming metal lines, particularly lines which are superconductive, involves delineating a pattern on a thin metal film on a substrate by masking techniques, ion implanting the metal film to a desired depth, removing the mask and etching away the unimplanted portion of the metal film to leave the line whose width is equal to the implanted depth. (U.K.)

  2. Revised Line Profile Function for Hydrogenic Species

    Directory of Open Access Journals (Sweden)

    Sapar A.

    2012-09-01

    Full Text Available Analytical series expansions for the hydrogenic spectral line profile functions are derived starting from the three single expressions, obtained by integrating twice the convolution of the Holtsmark, Lorentz and Doppler line profile functions. We get well converging series expansions for the line wings and centers by reducing the number of arguments in the profile function by one, introducing the module of the Holtsmark and Lorentz profiles as a new argument. In the intermediate part of the line, the parabolic cylinder functions expressed via the confluent hypergeometric series, are used. The multi-component Stark splitting of the hydrogenic spectral lines and the modeled stochastic electron transitions in the electric field of the adjacent ions generate wide Doppler plateaux at the line centers, with the characteristic widths estimated from the fit to the characteristic width of the Holtsmark profile. This additional Doppler broadening of the line profile function removes the central dip typical to the Holtsmark profile.

  3. Modeling operational behavior of a disassembly line

    Science.gov (United States)

    Kizilkaya, Elif A.; Gupta, Surendra M.

    2004-12-01

    In this paper we present a dynamic kanban (pull) system specifically developed for disassembly lines. This type of kanban system is much more complex than the traditional kanban system used in assembly lines. For instance, unlike the assembly line where the external demand occurs only at the last station, the demands in the disassembly case also occur at any of the intermittent stations. The reason is that as a product moves on the disassembly line, various parts are disassembled at every station and accumulated at that station. Therefore, there are as many demand sources as there are number of parts. We consider a case example involving the end-of-life products. Based on the precedence relationships and other criteria such as hazardous properties of the parts, we balance the disassembly line. The results of the disassembly line-balancing problem (DLBP) are used as input to the proposed dynamic kanban system for disassembly line (DKSDL). We compare the performance of the DKSDL to the modified kanban system for disassembly line (MKSDL), which was previously introduced by the authors. We show, via simulation, that the DKSDL is far superior to MKSDL considered.

  4. Autoionization spectral line shapes in dense plasmas

    International Nuclear Information System (INIS)

    Rosmej, F.B.; Hoffmann, D.H.H.; Faenov, A.Ya.; Pikuz, T.A.; Suess, W.; Geissel, M.

    2001-01-01

    The distortion of resonance line shapes due to the accumulation of a large number of satellite transitions is discovered by means of X-ray optical methods with simultaneous high spectral (λ/δλ≅8000) and spatial resolution (δx≅7 μm). Disappearance of the He α resonance line emission near the target surface is observed while Rydberg satellite intensity accumulates near the resonance line position. He β and He γ resonance line shapes are also shown to be seriously affected by opacity, higher-order line emissions from autoionizing states and inhomogeneous spatial emission. Opposite to resonance line emissions the He β satellites originate only from a very narrow spatial interval. New temperature and density diagnostics employing the 1s2131' and 1s3131'-satellites are developed. Moreover, even-J components of the satellite line emissions were resolved in the present high resolution experiments. Line transitions from the autoionizing states 1s2131' are therefore also proposed for space resolved Stark broadening analysis and local high density probing. Theorists are encouraged to provide accurate Stark broadening data for the transitions 1s2131 ' →1s 2 21+hv

  5. Displacement of location in illusory line motion.

    Science.gov (United States)

    Hubbard, Timothy L; Ruppel, Susan E

    2013-05-01

    Six experiments examined displacement in memory for the location of the line in illusory line motion (ILM; appearance or disappearance of a stationary cue is followed by appearance of a stationary line that is presented all at once, but the stationary line is perceived to "unfold" or "be drawn" from the end closest to the cue to the end most distant from the cue). If ILM was induced by having a single cue appear, then memory for the location of the line was displaced toward the cue, and displacement was larger if the line was closer to the cue. If ILM was induced by having one of two previously visible cues vanish, then memory for the location of the line was displaced away from the cue that vanished. In general, the magnitude of displacement increased and then decreased as retention interval increased from 50 to 250 ms and from 250 to 450 ms, respectively. Displacement of the line (a) is consistent with a combination of a spatial averaging of the locations of the cue and the line with a relatively weaker dynamic in the direction of illusory motion, (b) might be implemented in a spreading activation network similar to networks previously suggested to implement displacement resulting from implied or apparent motion, and (c) provides constraints and challenges for theories of ILM.

  6. Mechanical Behaviour of Lined Pipe

    NARCIS (Netherlands)

    Hilberink, A.

    2011-01-01

    Installing lined pipe by means of the reeling installation method seems to be an attractive combination, because it provides the opportunity of eliminating the demanding welds from the critical time offshore and instead preparing them onshore. However, reeling of lined pipe is not yet proven

  7. Status of ACCULINNA beam line

    CERN Document Server

    Rodin, A M; Bogdanov, D D; Golovkov, M S; Fomichev, A S; Sidorchuk, S I; Slepnev, R S; Wolski, R; Ter-Akopian, G M; Oganessian, Yu T; Yukhimchuk, A A; Perevozchikov, V V; Vinogradov, Yu I; Grishenchkin, S K; Demin, A M; Zlatoustovskii, S V; Kuryakin, A V; Filchagin, S V; Ilkaev, R I

    2003-01-01

    The separator ACCULINNA was upgraded to achieve new experimental requirements. The beam line was extended by new ion-optical elements beyond the cyclotron hall. The new arrangements yield much better background conditions. The intensities of sup 6 He and sup 8 He radioactive beams produced in fragmentation of 35 A MeV sup 1 sup 1 B ions were increased up to a factor of 10. The upgraded beam line was used in experiments to study the sup 5 H resonance states populated in the t+t reaction. A cryogenic liquid tritium target was designed and installed at the separator beam line.

  8. Collisionless reconnection: magnetic field line interaction

    Directory of Open Access Journals (Sweden)

    R. A. Treumann

    2012-10-01

    Full Text Available Magnetic field lines are quantum objects carrying one quantum Φ0 = 2πh/e of magnetic flux and have finite radius λm. Here we argue that they possess a very specific dynamical interaction. Parallel field lines reject each other. When confined to a certain area they form two-dimensional lattices of hexagonal structure. We estimate the filling factor of such an area. Anti-parallel field lines, on the other hand, attract each other. We identify the physical mechanism as being due to the action of the gauge potential field, which we determine quantum mechanically for two parallel and two anti-parallel field lines. The distortion of the quantum electrodynamic vacuum causes a cloud of virtual pairs. We calculate the virtual pair production rate from quantum electrodynamics and estimate the virtual pair cloud density, pair current and Lorentz force density acting on the field lines via the pair cloud. These properties of field line dynamics become important in collisionless reconnection, consistently explaining why and how reconnection can spontaneously set on in the field-free centre of a current sheet below the electron-inertial scale.

  9. The Pulse Line Ion Accelerator Concept

    Energy Technology Data Exchange (ETDEWEB)

    Briggs, Richard J.

    2006-02-15

    The Pulse Line Ion Accelerator concept was motivated by the desire for an inexpensive way to accelerate intense short pulse heavy ion beams to regimes of interest for studies of High Energy Density Physics and Warm Dense Matter. A pulse power driver applied at one end of a helical pulse line creates a traveling wave pulse that accelerates and axially confines the heavy ion beam pulse. Acceleration scenarios with constant parameter helical lines are described which result in output energies of a single stage much larger than the several hundred kilovolt peak voltages on the line, with a goal of 3-5 MeV/meter acceleration gradients. The concept might be described crudely as an ''air core'' induction linac where the PFN is integrated into the beam line so the accelerating voltage pulse can move along with the ions to get voltage multiplication.

  10. Stability of the LHC transfer lines

    CERN Document Server

    Kain, V; Bartmann, W; Bracco, C; Goddard, B; Meddahi, M; Uythoven, J; Wenninger, J

    2011-01-01

    The LHC is filled from the SPS through two 3 km transfer lines. The injected beam parameters need to be well under control for luminosity performance, machine protection and operational efficiency. Small fractions of beam loss on the transfer line collimation system create showers which can trigger the sensitive LHC beam loss monitor system nearby and cause a beam abort during filling. The stability of the transfer line trajectory through the collimators is particularly critical in this respect. This paper will report on the transfer line trajectory stability during the proton run in 2011, correlations with injection losses, correction frequency and the most likely sources for the observed oscillations.

  11. Correlation between the line width and the line flux of the double-peaked broad Hα of 3C390.3

    Science.gov (United States)

    Zhang, Xue-Guang

    2013-03-01

    In this paper, we carefully check the correlation between the line width (second moment) and the line flux of the double-peaked broad Hα of the well-known mapped active galactic nucleus (AGN) 3C390.3 in order to show some further distinctions between double-peaked emitters and normal broad-line AGN. Based on the virialization assumption MBH ∝ RBLR × V2(BLR) and the empirical relation RBLR ∝ L˜0.5, one strong negative correlation between the line width and the line flux of the double-peaked broad lines should be expected for 3C390.3, such as the negative correlation confirmed for the mapped broad-line object NGC 5548, RBLR × V2(BLR) ∝ L˜0.5 × σ2 = constant. Moreover, based on the public spectra around 1995 from the AGN WATCH project for 3C390.3, one reliable positive correlation is found between the line width and the line flux of the double-peaked broad Hα. In the context of the proposed theoretical accretion disc model for double-peaked emitters, the unexpected positive correlation can be naturally explained, due to different time delays for the inner and outer parts of the disc-like broad-line region (BLR) of 3C390.3. Moreover, the virialization assumption is checked and found to be still available for 3C390.3. However, the time-varying size of the BLR of 3C390.3 cannot be expected by the empirical relation RBLR ∝ L˜0.5. In other words, the mean size of the BLR of 3C390.3 can be estimated by the continuum luminosity (line luminosity), while the continuum emission strengthening leads to the size of BLR decreasing (not increasing) in different moments for 3C390.3. Then, we compared our results of 3C390.3 with the previous results reported in the literature for the other double-peaked emitters, and found that before to clearly correct the effects from disc physical parameters varying (such as the effects of disc precession) for long-term observed line spectra, it is not so meaningful to discuss the correlation of the line parameters of double

  12. Design of the Yang magnetically-insulated transmission line

    International Nuclear Information System (INIS)

    Gu Yuanchao; Song Shenyi

    2002-01-01

    The authors have designed a new magnetically insulated transmission line (MITL) for the Yang accelerator. The differences between the existing line and the designing one are given. The electric strength of some special regions on the lines and the inductance of the lines have been calculated. The authors have checked the states of magnetic insulation on the designing line

  13. Ghost lines in Moessbauer relaxation spectra

    International Nuclear Information System (INIS)

    Price, D.C.

    1985-01-01

    The appearance in Moessbauer relaxation spectra of 'ghost' lines, which are narrow lines that do not correspond to transitions between real hyperfine energy levels of the resonant system, is examined. It is shown that in many cases of interest, the appearance of these 'ghost' lines can be interpreted in terms of the relaxational averaging of one or more of the static interactions of the ion. (orig.)

  14. Line outage contingency analysis including the system islanding scenario

    Energy Technology Data Exchange (ETDEWEB)

    Hazarika, D.; Bhuyan, S. [Assam Engineering College, Jalukbari, Guwahati 781013 (India); Chowdhury, S.P. [Jadavpur University, Jadavpur, Kolkata 700 032 (India)

    2006-05-15

    The paper describes an algorithm for determining the line outage contingency of a line taking into account of line over load effect in remaining lines and subsequent tripping of over loaded line(s) leading to possible system split or islanding of a power system. The optimally ordered sparse [B'], [B'] matrices for the integrated system are used for load flow analysis to determine modified values of voltage phase angles [{delta}] and bus voltages [V] to determine the over loading effect on the remaining lines due to outage of a selected line outage contingency. In case of over loading in remaining line(s), the over loaded lines are removed from the system and a topology processor is used to find the islands. A fast decoupled load flow (FDLF) analysis is carried out for finding out the system variables for the islanded (or single island) system by incorporating appropriate modification in the [B'] and [B'] matrices of the integrated system. Line outage indices based on line overload, loss of load, loss of generation and static voltage stability are computed to indicate severity of a line outage of a selected line. (author)

  15. ExoMol line lists - VIII. A variationally computed line list for hot formaldehyde

    Science.gov (United States)

    Al-Refaie, Ahmed F.; Yachmenev, Andrey; Tennyson, Jonathan; Yurchenko, Sergei N.

    2015-04-01

    A computed line list for formaldehyde, H212C16O, applicable to temperatures up to T = 1500 K is presented. An empirical potential energy and ab initio dipole moment surfaces are used as the input to the nuclear motion program TROVE. The resulting line list, referred to as AYTY, contains 10.3 million rotational-vibrational states and around 10 billion transition frequencies. Each transition includes associated Einstein-A coefficients and absolute transition intensities, for wavenumbers below 10 000 cm-1 and rotational excitations up to J = 70. Room-temperature spectra are compared with laboratory measurements and data currently available in the HITRAN data base. These spectra show excellent agreement with experimental spectra and highlight the gaps and limitations of the HITRAN data. The full line list is available from the CDS data base as well as at www.exomol.com.

  16. On-line and off-line data analysis for the EUSO-TA experiment

    International Nuclear Information System (INIS)

    Piotrowski, Lech Wiktor; Casolino, Marco; Conti, Livio; Ebisuzaki, Toshikazu; Fornaro, Claudio; Kawasaki, Yoshiya; Hachisu, Yusuke; Ohmori, Hitoshi; De Santis, Cristian; Shinozaki, Kenji; Takizawa, Yoshiyuki; Uehara, Yoshihiro

    2015-01-01

    We show the principles of the communication protocol, on-line calibration, off-line data format as well as basic visualisation and data analysis software implemented for the EUSO-TA on-ground experiment, being the first step towards implementation in a future space based mission. EUSO-TA is an on-ground detector for measuring UV (290–430 nm) light from extensive air showers induced by cosmic rays. It is a prototype experiment for the JEM-EUSO space-borne mission, built according to the same constraints of low mass, low power consumption and thus low computing power. Nevertheless, it needs to process a huge amount of data in short time, taking 2.5μs exposures for 2304 channels. The low processing power and high time resolution require an efficient communication protocol and simple yet powerful algorithms for on-line analysis. The off-line data format is designed for storing a huge amount of data, at the same time allowing easy access, analysis and sharing. Its structure is scalable and adjustable to different experimental designs. It is independent of the data origin, whether it is hardware or a Monte-Carlo simulator. Use of object-oriented techniques and the ROOT framework allows rapid development of dedicated analysis software, such as a Python based quick-view program described herein. Basic capabilities of the software, such as display of the focal surface, light curves and calibration data are shown in this paper

  17. On-line and off-line data analysis for the EUSO-TA experiment

    Energy Technology Data Exchange (ETDEWEB)

    Piotrowski, Lech Wiktor, E-mail: lech.piotrowski@riken.jp [RIKEN, Wako (Japan); Casolino, Marco [RIKEN, Wako (Japan); INFN and Univ. Rome Tor Vergata, Rome (Italy); Conti, Livio [International Telematic University UNINETTUNO, Rome (Italy); Ebisuzaki, Toshikazu [RIKEN, Wako (Japan); Fornaro, Claudio [International Telematic University UNINETTUNO, Rome (Italy); Kawasaki, Yoshiya; Hachisu, Yusuke; Ohmori, Hitoshi [RIKEN, Wako (Japan); De Santis, Cristian [INFN and Univ. Rome Tor Vergata, Rome (Italy); Shinozaki, Kenji [Institute for Astronomy and Astrophysics, Kepler Center, University of Tübingen, Sand 6, D-72076 Tübingen (Germany); RIKEN, Wako (Japan); Takizawa, Yoshiyuki; Uehara, Yoshihiro [RIKEN, Wako (Japan)

    2015-02-11

    We show the principles of the communication protocol, on-line calibration, off-line data format as well as basic visualisation and data analysis software implemented for the EUSO-TA on-ground experiment, being the first step towards implementation in a future space based mission. EUSO-TA is an on-ground detector for measuring UV (290–430 nm) light from extensive air showers induced by cosmic rays. It is a prototype experiment for the JEM-EUSO space-borne mission, built according to the same constraints of low mass, low power consumption and thus low computing power. Nevertheless, it needs to process a huge amount of data in short time, taking 2.5μs exposures for 2304 channels. The low processing power and high time resolution require an efficient communication protocol and simple yet powerful algorithms for on-line analysis. The off-line data format is designed for storing a huge amount of data, at the same time allowing easy access, analysis and sharing. Its structure is scalable and adjustable to different experimental designs. It is independent of the data origin, whether it is hardware or a Monte-Carlo simulator. Use of object-oriented techniques and the ROOT framework allows rapid development of dedicated analysis software, such as a Python based quick-view program described herein. Basic capabilities of the software, such as display of the focal surface, light curves and calibration data are shown in this paper.

  18. 78 FR 76711 - Royal City Charter Coach Lines Ltd.-Acquisition of Control-Quick Coach Lines Ltd. d/b/a Quick...

    Science.gov (United States)

    2013-12-18

    ... current ownership of Quick, and its wholly owned subsidiary Quick Coach Lines USA Inc. (Quick USA... Charter Coach Lines Ltd.--Acquisition of Control-- Quick Coach Lines Ltd. d/b/a Quick Shuttle Service.... SUMMARY: On November 18, 2013, Royal City Charter Coach Lines Ltd. (Royal, or Applicant) filed an...

  19. Long-distance pulse propagation on high-frequency dissipative nonlinear transmission lines/resonant tunneling diode line cascaded maps

    International Nuclear Information System (INIS)

    Klofai, Yerima; Essimbi, B Z; Jaeger, D

    2011-01-01

    Pulse propagation on high-frequency dissipative nonlinear transmission lines (NLTLs)/resonant tunneling diode line cascaded maps is investigated for long-distance propagation of short pulses. Applying perturbative analysis, we show that the dynamics of each line is reduced to an expanded Korteweg-de Vries-Burgers equation. Moreover, it is found by computer experiments that the soliton developed in NLTLs experiences an exponential amplitude decay on the one hand and an exponential amplitude growth on the other. As a result, the behavior of a pulse in special electrical networks made of concatenated pieces of lines is closely similar to the transmission of information in optical/electrical communication systems.

  20. Long-distance pulse propagation on high-frequency dissipative nonlinear transmission lines/resonant tunneling diode line cascaded maps

    Energy Technology Data Exchange (ETDEWEB)

    Klofai, Yerima [Department of Physics, Higher Teacher Training College, University of Maroua, PO Box 46 Maroua (Cameroon); Essimbi, B Z [Department of Physics, Faculty of Science, University of Yaounde 1, PO Box 812 Yaounde (Cameroon); Jaeger, D, E-mail: bessimb@yahoo.fr [ZHO, Optoelectronik, Universitaet Duisburg-Essen, D-47048 Duisburg (Germany)

    2011-10-15

    Pulse propagation on high-frequency dissipative nonlinear transmission lines (NLTLs)/resonant tunneling diode line cascaded maps is investigated for long-distance propagation of short pulses. Applying perturbative analysis, we show that the dynamics of each line is reduced to an expanded Korteweg-de Vries-Burgers equation. Moreover, it is found by computer experiments that the soliton developed in NLTLs experiences an exponential amplitude decay on the one hand and an exponential amplitude growth on the other. As a result, the behavior of a pulse in special electrical networks made of concatenated pieces of lines is closely similar to the transmission of information in optical/electrical communication systems.