WorldWideScience

Sample records for binary diffusion coefficient

  1. Measurement of chemical diffusion coefficients in liquid binary alloys

    International Nuclear Information System (INIS)

    Keita, M.; Steinemann, S.; Kuenzi, H.U.

    1976-01-01

    New measurements of the chemical diffusion coefficient in liquid binary alloys are presented. The wellknown geometry of the 'capillary-reservoir' is used and the concentration is obtained from a resistivity measurement. The method allows to follow continuously the diffusion process in the liquid state. A precision of at least 10% in the diffusion coefficient is obtained with a reproductibility better than 5%. The systems Hg-In, Al-Sn, Al-Si have been studied. Diffusion coefficients are obtained as a function of temperature, concentration, and geometrical factors related to the capillary (diameter, relative orientation of density gradient and gravity). (orig.) [de

  2. DETERMINATION OF DIFFUSION COEFFICIENTS OF BINARY LIQUID SYSTEMS

    Directory of Open Access Journals (Sweden)

    Erol İNCE

    2001-03-01

    Full Text Available The diaphragm cell method technique was used to determine the diffusion coefficients of selected binary systems (Cyclopentanol-Acetic acid, Cyclohexanol-Acetic acid and Methylcyclohexanol-Acetic acid. The technique was chosen because of simplicity and accuracy. The stirring rate was 60 rpm. The diaphragm cell was calibrated at 298.15 K by diffusing of 0.1 N KCl solution into distilled water. The experimental diaphragm cell constant (ß was found 0.09293 cm -2 . The temperature of water bath was controlled by a contact thermometer with an accuracy of ± 0.1 °C. The obtained experimental diffusion coefficients for Cyclopentanol-Acetic acid, Cyclohexanol-Acetic acid and Methylcyclohexanol - Acetic acid binary systems were 2.40 x 10 -5 cm 2 /s, 1.16 x 10 -5 cm 2 /s, 3.97 x 10 -5 cm 2 /s, respectively. Furthermore, diffusion coefficients have been estimated by the theoretical methods of Wilke - Chang and Scheibel equations and compared with the experimental results.

  3. Modeling diffusion coefficients in binary mixtures of polar and non-polar compounds

    DEFF Research Database (Denmark)

    Medvedev, Oleg; Shapiro, Alexander

    2005-01-01

    The theory of transport coefficients in liquids, developed previously, is tested on a description of the diffusion coefficients in binary polar/non-polar mixtures, by applying advanced thermodynamic models. Comparison to a large set of experimental data shows good performance of the model. Only...

  4. Mass-dependence of self-diffusion coefficients in disparate-mass binary fluid mixtures

    Directory of Open Access Journals (Sweden)

    I. Binas

    2009-01-01

    Full Text Available Self-diffusion coefficients of a binary fluid mixture with components differing only in their particle masses are studied, in particular the case when mass ratio μ of light and heavy particles tends to zero. These coefficients were calculated within the memory function formalism, using the systematic subsequence of approximations for the relaxation times of velocity autocorrelation function. We obtained a general relation for the self-diffusion coefficients which show polynomial dependence on the mass ratio μ. The obtained expression has a correct Brownian limit. We developed the hierarchy of approximations for the self-diffusion coefficients that tends to an exact result from above and below when the order of approximations increases.

  5. Generalized Einstein relation for the mutual diffusion coefficient of a binary fluid mixture.

    Science.gov (United States)

    Felderhof, B U

    2017-08-21

    The method employed by Einstein to derive his famous relation between the diffusion coefficient and the friction coefficient of a Brownian particle is used to derive a generalized Einstein relation for the mutual diffusion coefficient of a binary fluid mixture. The expression is compared with the one derived by de Groot and Mazur from irreversible thermodynamics and later by Batchelor for a Brownian suspension. A different result was derived by several other workers in irreversible thermodynamics. For a nearly incompressible solution, the generalized Einstein relation agrees with the expression derived by de Groot and Mazur. The two expressions also agree to first order in solute density. For a Brownian suspension, the result derived from the generalized Smoluchowski equation agrees with both expressions.

  6. Theory and Experiment of Binary Diffusion Coefficient of n-Alkanes in Dilute Gases.

    Science.gov (United States)

    Liu, Changran; McGivern, W Sean; Manion, Jeffrey A; Wang, Hai

    2016-10-10

    Binary diffusion coefficients were measured for n-pentane, n-hexane, and n-octane in helium and of n-pentane in nitrogen over the temperature range of 300 to 600 K, using reversed-flow gas chromatography. A generalized, analytical theory is proposed for the binary diffusion coefficients of long-chain molecules in simple diluent gases, taking advantage of a recently developed gas-kinetic theory of the transport properties of nanoslender bodies in dilute free-molecular flows. The theory addresses the long-standing question about the applicability of the Chapman-Enskog theory in describing the transport properties of nonspherical molecular structures, or equivalently, the use of isotropic potentials of interaction for a roughly cylindrical molecular structure such as large normal alkanes. An approximate potential energy function is proposed for the intermolecular interaction of long-chain n-alkane with typical bath gases. Using this potential and the analytical theory for nanoslender bodies, we show that the diffusion coefficients of n-alkanes in typical bath gases can be treated by the resulting analytical model accurately, especially for compounds larger than n-butane.

  7. Methodology for using prompt gamma activation analysis to measure the binary diffusion coefficient of a gas in a porous medium

    International Nuclear Information System (INIS)

    Rios Perez, Carlos A.; Biegalski, Steve R.; Deinert, Mark R.

    2012-01-01

    Highlights: ► Prompt gamma activation analysis is used to study gas diffusion in a porous system. ► Diffusion coefficients are determined using prompt gamma activation analysis. ► Predictions concentrations fit experimental measurements with an R 2 of 0.98. - Abstract: Diffusion plays a critical role in determining the rate at which gases migrate through porous systems. Accurate estimates of diffusion coefficients are essential if gas transport is to be accurately modeled and better techniques are needed that can be used to measure these coefficients non-invasively. Here we present a novel method for using prompt gamma activation analysis to determine the binary diffusion coefficients of a gas in a porous system. Argon diffusion experiments were conducted in a 1 m long, 10 cm diameter, horizontal column packed with a SiO 2 sand. The temporal variation of argon concentration within the system was measured using prompt gamma activation analysis. The binary diffusion coefficient was obtained by comparing the experimental data with the predictions from a numerical model in which the diffusion coefficient was varied until the sum of square errors between experiment and model data was minimized. Predictions of argon concentration using the optimal diffusivity fit experimental measurements with an R 2 of 0.983.

  8. Impact of polyethyleneglycol addition on diffusion coefficients in binary ionic liquid electrolytes composed of dicationic ionic liquid and polyethyleneglycol.

    Science.gov (United States)

    Wu, Tzi-Yi; Su, Shyh-Gang; Chiu, Chuen-Lin; Kuo, Chung-Wen; Tung, Yi-Hsuan

    2018-02-01

    We conduct a comparative study of conductivity and diffusion coefficient of two dicationic ionic liquids (3,3'-(octane-1,8-diyl)bis(1-ethyl-3-imidazolium) bis(trifluoromethylsulfonyl)amide ([IMCI][TFSI], S1) and 3,3'-(2,2'-(ethane-1,2-diylbis(oxy))bis(ethane-2,1-diyl))bis(1-ethyl-3-imidazolium) bis(trifluoromethylsulfonyl)amide ([IMOI][TFSI], S2)) at various temperatures. The diffusion coefficients of cation and anion in ionic liquids are determined by using pulse gradient spin-echo nuclear magnetic resonance method. S2 shows lower viscosity, higher conductivity, and higher diffusion coefficient than those of S1. Moreover, the influence of polyethyleneglycol (PEG200, M w  = 200) addition in PEG200/IL binary solutions is investigated. PEG200/S1 binary solutions show lower viscosity, higher conductivity, and higher diffusion coefficient than those of neat S1. The experimental molar conductivity (Λ) of neat IL and PEG200/IL binary solutions is lower than that of the calculated molar conductivity (Λ NMR ) from pulse gradient spin-echo nuclear magnetic resonance method at various temperatures, indicating that not all the diffusion species belong to the ionic conduction. In other words, NMR diffusion measurements comprise charged and paired (without charge) ions. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  9. Estimation of Knudsen diffusion coefficients from tracer experiments conducted with a binary gas system and a porous medium.

    Science.gov (United States)

    Hibi, Yoshihiko; Kashihara, Ayumi

    2018-03-01

    A previous study has reported that Knudsen diffusion coefficients obtained by tracer experiments conducted with a binary gas system and a porous medium are consistently smaller than those obtained by permeability experiments conducted with a single-gas system and a porous medium. To date, however, that study is the only one in which tracer experiments have been conducted with a binary gas system. Therefore, to confirm this difference in Knudsen diffusion coefficients, we used a method we had developed previously to conduct tracer experiments with a binary carbon dioxide-nitrogen gas system and five porous media with permeability coefficients ranging from 10 -13 to 10 -11  m 2 . The results showed that the Knudsen diffusion coefficient of N 2 (D N2 ) (cm 2 /s) was related to the effective permeability coefficient k e (m 2 ) as D N2  = 7.39 × 10 7 k e 0.767 . Thus, the Knudsen diffusion coefficients of N 2 obtained by our tracer experiments were consistently 1/27 of those obtained by permeability experiments conducted with many porous media and air by other researchers. By using an inversion simulation to fit the advection-diffusion equation to the distribution of concentrations at observation points calculated by mathematically solving the equation, we confirmed that the method used to obtain the Knudsen diffusion coefficient in this study yielded accurate values. Moreover, because the Knudsen diffusion coefficient did not differ when columns with two different lengths, 900 and 1500 mm, were used, this column property did not influence the flow of gas in the column. The equation of the dusty gas model already includes obstruction factors for Knudsen diffusion and molecular diffusion, which relate to medium heterogeneity and tortuosity and depend only on the structure of the porous medium. Furthermore, there is no need to take account of any additional correction factor for molecular diffusion except the obstruction factor because molecular diffusion is

  10. Calculation of Viscosity and Diffusion Coefficients for Two Binary Gaseous Mixtures Using the Semi-empirical Inversion Method

    Science.gov (United States)

    Rafiee, Hamid Reza; Rastgar, Mina; Heidari, Neda

    2011-08-01

    The accurate reduced potential energies for two binary gas mixtures including benzene-methanol and methane-tetrafluoromethane at low density have been obtained by direct inversion of the viscosity collision integral equations. The kinetic theory along with the extended principle of corresponding-states has been used to calculate the viscosity and diffusion coefficients over a wide range of temperature and composition. Good agreements between calculated and experimental data are obtained.

  11. Thermal Diffusion in Binary Mixtures: Transient Behavior and Transport Coefficients from Equilibrium and Nonequilibrium Molecular Dynamics.

    Science.gov (United States)

    Bonella, Sara; Ferrario, Mauro; Ciccotti, Giovanni

    2017-10-24

    Equilibrium and nonequilibrium molecular dynamics simulations are combined to compute the full set of coefficients that appear in the phenomenological equations describing thermal transport in a binary mixture subject to a constant thermal gradient. The Dynamical Non-Equilibrium Molecular Dynamics approach (D-NEMD) is employed to obtain the microscopic time evolution of the density and temperature fields, together with that of the mass and energy fluxes. D-NEMD enables one to study not only the steady state, but also the evolution of the fields during the transient that follows the onset of the thermal gradient, up to the establishment of the steady state. This makes it possible to ensure that the system has indeed reached a stationary condition, and to analyze the transient mechanisms and time scales of the mass and energy transport. A local time averaging procedure is applied to each trajectory contributing to the calculation to improve the signal-to-noise ratio in the estimation of the fluxes and to obtain a clear signal with the, relatively limited, statistics available.

  12. Diffusion coefficient in photon diffusion theory

    NARCIS (Netherlands)

    Graaff, R; Ten Bosch, JJ

    2000-01-01

    The choice of the diffusion coefficient to be used in photon diffusion theory has been a subject of discussion in recent publications on tissue optics. We compared several diffusion coefficients with the apparent diffusion coefficient from the more fundamental transport theory, D-app. Application to

  13. Explicit expressions of self-diffusion coefficient, shear viscosity, and the Stokes-Einstein relation for binary mixtures of Lennard-Jones liquids

    International Nuclear Information System (INIS)

    Ohtori, Norikazu; Ishii, Yoshiki

    2015-01-01

    Explicit expressions of the self-diffusion coefficient, D i , and shear viscosity, η sv , are presented for Lennard-Jones (LJ) binary mixtures in the liquid states along the saturated vapor line. The variables necessary for the expressions were derived from dimensional analysis of the properties: atomic mass, number density, packing fraction, temperature, and the size and energy parameters used in the LJ potential. The unknown dependence of the properties on each variable was determined by molecular dynamics (MD) calculations for an equimolar mixture of Ar and Kr at the temperature of 140 K and density of 1676 kg m −3 . The scaling equations obtained by multiplying all the single-variable dependences can well express D i and η sv evaluated by the MD simulation for a whole range of compositions and temperatures without any significant coupling between the variables. The equation for D i can also explain the dual atomic-mass dependence, i.e., the average-mass and the individual-mass dependence; the latter accounts for the “isotope effect” on D i . The Stokes-Einstein (SE) relation obtained from these equations is fully consistent with the SE relation for pure LJ liquids and that for infinitely dilute solutions. The main differences from the original SE relation are the presence of dependence on the individual mass and on the individual energy parameter. In addition, the packing-fraction dependence turned out to bridge another gap between the present and original SE relations as well as unifying the SE relation between pure liquids and infinitely dilute solutions

  14. Explicit expressions of self-diffusion coefficient, shear viscosity, and the Stokes-Einstein relation for binary mixtures of Lennard-Jones liquids

    Energy Technology Data Exchange (ETDEWEB)

    Ohtori, Norikazu, E-mail: ohtori@chem.sc.niigata-u.ac.jp [Department of Chemistry, Niigata University, 8050 Ikarashi 2-no-cho, Nishi-ku, Niigata 950-2181 (Japan); Ishii, Yoshiki [Graduate School of Science and Technology, Niigata University, 8050 Ikarashi 2-no-cho, Nishi-ku, Niigata 950-2181 (Japan)

    2015-10-28

    Explicit expressions of the self-diffusion coefficient, D{sub i}, and shear viscosity, η{sub sv}, are presented for Lennard-Jones (LJ) binary mixtures in the liquid states along the saturated vapor line. The variables necessary for the expressions were derived from dimensional analysis of the properties: atomic mass, number density, packing fraction, temperature, and the size and energy parameters used in the LJ potential. The unknown dependence of the properties on each variable was determined by molecular dynamics (MD) calculations for an equimolar mixture of Ar and Kr at the temperature of 140 K and density of 1676 kg m{sup −3}. The scaling equations obtained by multiplying all the single-variable dependences can well express D{sub i} and η{sub sv} evaluated by the MD simulation for a whole range of compositions and temperatures without any significant coupling between the variables. The equation for D{sub i} can also explain the dual atomic-mass dependence, i.e., the average-mass and the individual-mass dependence; the latter accounts for the “isotope effect” on D{sub i}. The Stokes-Einstein (SE) relation obtained from these equations is fully consistent with the SE relation for pure LJ liquids and that for infinitely dilute solutions. The main differences from the original SE relation are the presence of dependence on the individual mass and on the individual energy parameter. In addition, the packing-fraction dependence turned out to bridge another gap between the present and original SE relations as well as unifying the SE relation between pure liquids and infinitely dilute solutions.

  15. The surface diffusion coefficient for an arbitrarily curved fluidfluid interface.(II). Coefficient for plane-parallel diffusion

    NARCIS (Netherlands)

    Sagis, L.M.C.

    2001-01-01

    In this paper we developed an expression for the coefficient for plane-parallel diffusion for an arbitrarily curved fluid–fluid interface. The expression is valid for ordinary diffusion in binary mixtures, with isotropic bulk phases and an interfacial region that is isotropic in the plane parallel

  16. Diffusion in ordered binary solid systems

    International Nuclear Information System (INIS)

    Stolwijk, N.A.

    1980-01-01

    This thesis contains contributions to the field of diffusion in ordered binary solid systems. An extensive experimental investigation of the self diffusion in CoGa is presented. The results of these diffusion measurements strongly suggest that a substantial part of the atomic migration is caused by a new type of defect. A quantitative description of the atomic displacements via this defect is given. Finally computer simulations are presented of diffusion and ordering in binary solid systems. (Auth.)

  17. Estimation of tracer diffusion coefficients of ions in aqueous solution

    International Nuclear Information System (INIS)

    Miller, D.G.

    1982-01-01

    Equations are given for estimating tracer diffusion coefficients D/sub i/ 0 of ions at infinite dilution in terms of limiting ionic conductances Λ/sub i/ 0 . Also given are generalized Nernst-Hartley equations for binary and multicomponent diffusion coefficients D 0 and D/sub ij/ 0 , respectively, at infinite dilution. Data, estimates, and correlations for Λ/sub i/ 0 at 25 0 C and other temperatures are discussed. Estimated values of Λ/sub i/ 0 are tabulated from 0-300 0 C for ions of waste isolation interest and for ions of economic interest in geothermal brines. Estimates of their tracer diffusion coefficients at infinite dilution are tabulated. A rule of thumb, good to a factor of 2, is presented. Very limited data (available only at 25 0 C) indicate that D/sub i//D/sub i/ 0 generally declines as the concentration of salt or supporting electrolyte increases. 6 figures, 2 tables

  18. Problems with Discontinuous Diffusion/Dispersion Coefficients

    Directory of Open Access Journals (Sweden)

    Stefano Ferraris

    2012-01-01

    accurate on smooth solutions and based on a special numerical treatment of the diffusion/dispersion coefficients that makes its application possible also when such coefficients are discontinuous. Numerical experiments confirm the convergence of the numerical approximation and show a good behavior on a set of benchmark problems in two space dimensions.

  19. Lattice cell diffusion coefficients. Definitions and comparisons

    International Nuclear Information System (INIS)

    Hughes, R.P.

    1980-01-01

    Definitions of equivalent diffusion coefficients for regular lattices of heterogeneous cells have been given by several authors. The paper begins by reviewing these different definitions and the unification of their derivation. This unification makes clear how accurately each definition (together with appropriate cross-section definitions to preserve the eigenvalue) represents the individual reaction rates within the cell. The approach can be extended to include asymmetric cells and whereas before, the buckling describing the macroscopic flux shape was real, here it is found to be complex. A neutron ''drift'' coefficient as well as a diffusion coefficient is necessary to produce the macroscopic flux shape. The numerical calculation of the various different diffusion coefficients requires the solutions of equations similar to the ordinary transport equation for an infinite lattice. Traditional reactor physics codes are not sufficiently flexible to solve these equations in general. However, calculations in certain simple cases are presented and the theoretical results quantified. In difficult geometries, Monte Carlo techniques can be used to calculate an effective diffusion coefficient. These methods relate to those already described provided that correlation effects between different generations of neutrons are included. Again, these effects are quantified in certain simple cases. (author)

  20. Vertical diffuse attenuation coefficient (Kd) based optical ...

    Indian Academy of Sciences (India)

    R. Narasimhan (Krishtel eMaging) 1461 1996 Oct 15 13:05:22

    The optical classification of the different water types provides vital input for studies related to primary productivity, water clarity and determination of euphotic depth. Image data of the IRS-. P3 MOS-B, for Path 90 of 27th February, 1998 was used for deriving vertical diffuse attenuation coefficient (Kd) and an optical ...

  1. Vertical diffuse attenuation coefficient (Kd) based optical ...

    Indian Academy of Sciences (India)

    R. Narasimhan (Krishtel eMaging) 1461 1996 Oct 15 13:05:22

    mary production and diffuse attenuation coeffi- cient (Austin 1981; Sathyendranath et al 2000). The Indian IRS-P3 ... oceanic and coastal production of phytoplank- ton (Tyler 1975; Pennock and Sharp 1986). As a result basic ... cient to the plant pigment content. The term dif- fuse attenuation coefficient, most commonly used.

  2. Diffusive flux of energy in binary mixtures

    International Nuclear Information System (INIS)

    Sampaio, R.S.

    1976-04-01

    The diffusive flux of energy j tilde is studied through the reduced diffusive flux of energy K tilde, which obeys equations of the form: sim(delta K tilde/delta grad rho sub(α))= sim(delta K tilde/delta grad theta)=0. By a representation theorem, herein proved, is obtained a general representation for K tilde which is simplified, for the case of binary mixtures, using the principle of objectivity. Some consequences of this representation are discussed such as the symmetry of the partial stresses T 1 tilde and T 2 tilde and the difference between the normal stresses [pt

  3. Effective Diffusion Coefficients in Coal Chars

    DEFF Research Database (Denmark)

    Johnsson, Jan Erik; Jensen, Anker

    2001-01-01

    Knowledge of effective diffusion coefficients in char particles is important when interpreting experimental reactivity measurements and modeling char combustion or NO and N2O reduction. In this work, NO and N2O reaction with a bituminous coal char was studied in a fixed-bed quartz glass reactor....... In the case of strong pore diffusion limitations, the error in the interpretation of experimental results using the mean pore radius could be a factor of 5 on the intrinsic rate constant. For an average coal char reacting with oxygen at 1300 K, this would be the case for particle sizes larger than about 50...

  4. Extending reversed-flow chromatographic methods for the measurement of diffusion coefficients to higher temperatures.

    Science.gov (United States)

    McGivern, W Sean; Manion, Jeffrey A

    2011-11-18

    A reversed-flow gas-chromatography (RF-GC) apparatus for the measurement of binary diffusion coefficients is described and utilized to measure the binary diffusion coefficients for several systems at temperatures from (300 to 723)K. Hydrocarbons are detected using flame ionization detection, and inert species can be detected by thermal conductivity. The present apparatus has been utilized to measure diffusion coefficients at substantially higher temperatures than previous RF-GC work. Characterization of the new apparatus was accomplished by comparing measured binary diffusion coefficients of dilute argon in helium to established reference values. Further diffusion coefficient measurements for dilute helium in argon and dilute nitrogen in helium (using thermal conductivity detection) and dilute methane in helium (using flame ionization detection) were performed and found to be in excellent agreement with literature values. The measurement of these well-established diffusion coefficients has shown that specific experimental conditions are required for accurate diffusion measurements using this technique, particularly at higher temperatures. Numerical simulations of the diffusion experiments are presented to demonstrate that artifacts of the analysis procedure must be specifically identified to ensure accuracy, particularly at higher temperatures. Published by Elsevier B.V.

  5. Thermal neutron diffusion cooling coefficient for plexiglass

    International Nuclear Information System (INIS)

    Drozdowicz, K.

    1992-08-01

    The thermal neutron diffusion cooling coefficient is a macroscopic material parameter. It is needed for description of the decay of the thermal neutron pulse in a medium and gives information of the diffusion cooling of the thermal neutron spectrum in a bounded volume. Experimental results from various measurements for plexiglass are overviewed in the paper. A method for theoretical, exact calculation of the parameter is presented. The formula utilizes some other thermal neutron parameters and a cooling function, i.e. the function which describes the deviation of the neutron spectrum in a bounded system from the distribution in an infinite one. The energy dependence of the function is obtained numerically from relations which results from the eigenvalue problem of the scattering operator when both the decay constant and the spectrum of the thermal neutron flux are developed on powers of the geometrical buckling. The case of a 1/ν absorption cross section is considered. The calculation utilizes a synthetic scattering function elaborated for hydrogenous media by GRANADA (1985). The influence of some quantities used in the calculation on the final result is investigated. The obtained value of the diffusion cooling coefficient for plexiglass is C = 6514 cm 4 s -1 at the temperature of 20 degrees C. The uncertainty is estimated to be ± 100 cm 4 s -1 within the physical model of the scattering kernel used. (au)

  6. A Simple Educational Method for the Measurement of Liquid Binary Diffusivities

    Science.gov (United States)

    Rice, Nicholas P.; de Beer, Martin P.; Williamson, Mark E.

    2014-01-01

    A simple low-cost experiment has been developed for the measurement of the binary diffusion coefficients of liquid substances. The experiment is suitable for demonstrating molecular diffusion to small or large undergraduate classes in chemistry or chemical engineering. Students use a cell phone camera in conjunction with open-source image…

  7. Insight into interrelation between single-particle and collective diffusion in binary melts

    Science.gov (United States)

    Levchenko, Elena V.; Evteev, Alexander V.

    2018-01-01

    The interrelation between the kinetics of single-particle (tracer) and collective diffusion in a binary melt is investigated theoretically within the framework of the Mori-Zwanzig formalism of statistical mechanics. An analytical expression for the Onsager coefficient for mass transport and two self-diffusion coefficients of species in a binary melt is derived using analysis based on the generalized Langevin equation. The derived expression naturally accounts for manifestation of microscopic (dynamic) cross-correlation effects in the kinetics of collective diffusion. Hence, it presents an explicit extension of the well-known Darken equation which is currently often used for expressing collective interdiffusion in terms of the two self-diffusion coefficients. An application of our analysis for interpretation of recent experimental data on the interrelation between the kinetics of single-particle and collective diffusion in Al-rich Ni-Al melts is demonstrated.

  8. Calculation of diffusion coefficients for carbon dioxide + solute system near the critical conditions by non-equilibrium molecular dynamics simulation

    OpenAIRE

    Higashi, Hidenori; Oda, Tsuyoshi; Iwai, Yoshio; Arai, Yasuhiko

    2004-01-01

    A non-equilibrium molecular dynamics simulation was adopted to calculate the diffusion coefficients for a pseudo-binary system of carbon dioxide and for a carbon dioxide + solute system at 308.2 and 318.2K. The calculated results were compared with the self- and tracer diffusion coefficients calculated by an equilibrium molecular dynamics simulation. The simulated results for the pseudo-binary system of carbon dioxide by the non-equilibrium molecular dynamics simulation are in good agreement ...

  9. Diffuse interface method for a compressible binary fluid.

    Science.gov (United States)

    Liu, Jiewei; Amberg, Gustav; Do-Quang, Minh

    2016-01-01

    Multicomponent, multiphase, compressible flows are very important in real life, as well as in scientific research, while their modeling is in an early stage. In this paper, we propose a diffuse interface model for compressible binary mixtures, based on the balance of mass, momentum, energy, and the second law of thermodynamics. We show both analytically and numerically that this model is able to describe the phase equilibrium for a real binary mixture (CO_{2} + ethanol is considered in this paper) very well by adjusting the parameter which measures the attraction force between molecules of the two components in the model. We also show that the calculated surface tension of the CO_{2} + ethanol mixture at different concentrations match measurements in the literature when the mixing capillary coefficient is taken to be the geometric mean of the capillary coefficient of each component. Three different cases of two droplets in a shear flow, with the same or different concentration, are simulated, showing that the higher concentration of CO_{2} the smaller the surface tension and the easier the drop deforms.

  10. Diffusion coefficient of three-dimensional Yukawa liquids

    Energy Technology Data Exchange (ETDEWEB)

    Dzhumagulova, K. N.; Ramazanov, T. S.; Masheeva, R. U. [IETP, Al Farabi Kazakh National University, 71, al Farabi ave., Almaty 050040 (Kazakhstan)

    2013-11-15

    The purpose of this work is an investigation of the diffusion coefficient of the dust component in complex plasma. The computer simulation of the Yukawa liquids was made on the basis of the Langevin equation, which takes into account the influence of buffer plasma on the dust particles dynamics. The Green–Kubo relation was used to calculate the diffusion coefficient. Calculations of the diffusion coefficient for a wide range of the system parameters were performed. Using obtained numerical data, we constructed the interpolation formula for the diffusion coefficient. We also show that the interpolation formula correctly describes experimental data obtained under microgravity conditions.

  11. DCCO and SCCO: measurements of diffusion coefficients and of thermodiffusion in microgravity; DCCO et SCCO: mesures de coefficients de diffusion et de thermodiffusion en microgravite

    Energy Technology Data Exchange (ETDEWEB)

    Legros, J.C.; Van Vaerenbergh, S.; Dubois, F.; Decroly, Y. [Universite Libre de Bruxelles (Belgium); Montel, F. [ELF-Aquitaine Production, 64 - Pau (France); Goodman, S. [C-CORE, New Foundland, (Canada); Bekaert, G. [SABCA, Bruxelles (Belgium); Van Ransbeek, E. [IASB-BIRA, Bruxelles (Belgium)

    1996-12-31

    Measurements of diffusion coefficients of ternary systems and of thermodiffusion coefficients of multicomponent systems, including crude oils, have been undertaken by MRC and Elf-Aquitaine. The experiments DCCO and SCCO (respectively Diffusion and Soret Coefficients of Crude Oils) will be performed in 1997 and 1998 in GAS containers on the Space Shuttle. The 9 systems of DCCO are analyzed by Mach-Zehnder bicolor interferometry. The samples of the 18 systems of SCCO, among which three at 300 bars and at a mean temperature of 60 deg. C, will be analyzed after recovery on ground by a chromatographic technique. Such measurements performed in microgravity, like the measurements of Soret coefficients of binary solutions performed in the microgravity SCM experiments, are necessary reference measurements. (authors) 12 refs.

  12. Effect of system variables involved in packed column SFC of nevirapine as model analyte using response surface methodology: application to retention thermodynamics, solute transfer kinetic study and binary diffusion coefficient determination.

    Science.gov (United States)

    Kaul, Neerej; Agrawal, Himani; Paradkar, A R; Mahadik, K R

    2005-08-31

    A multifactor optimization technique is successfully applied to study the effect of simultaneously varying the system variables on feasibility of nevirapine analysis by packed column supercritical fluid chromatography (PC-SFC). The optimal conditions were determined with the aid of the response surface methodology using 3(3) factorial designs. The method is based on methanol-modified carbon dioxide as the mobile phase at flow rate of 3.0 ml/min with elution through a JASCO Finepak SIL-5, [C18 (5-micron, 25 cm x 4.6 mm, i.d.)] column using photodiode array detection. The method has been successfully used to analyze commercial solid dosage form to assess the chromatographic performance of SFC system. The present work briefs the thermodynamic applications of PC-SFC with an emphasis on the results of nevirapine. The foremost of such applications is the determination of solute diffusion coefficient in supercritical mobile phase by Taylor-Aris peak broadening technique.

  13. Quaternary ammonium room-temperature ionic liquid including an oxygen atom in side chain/lithium salt binary electrolytes: ionic conductivity and 1H, 7Li, and 19F NMR studies on diffusion coefficients and local motions.

    Science.gov (United States)

    Hayamizu, Kikuko; Tsuzuki, Seiji; Seki, Shiro; Ohno, Yasutaka; Miyashiro, Hajime; Kobayashi, Yo

    2008-01-31

    A room-temperature ionic liquid (RTIL) of a quaternary ammonium cation having an ether chain, N,N-diethyl-N-methyl-N-(2-methoxyethyl)ammonium bis(trifluoromethylsulfonyl)amide (DEME-TFSA), is a candidate for use as an electrolyte of lithium secondary batteries. In this study, the electrochemical ionic conductivity, sigma, of the neat DEME-TFSA and DEME-TFSA-Li doped with five different concentrations of lithium salt (LiTFSA) was measured and correlated with NMR measurements of the diffusion coefficients D and the spin-lattice relaxation times T1 of the individual components DEME (1H), TFSA (19F), and lithium ion (7Li). The ion conduction of charged ions can be activated with less thermal energy than ion diffusion which contains a contribution from paired ions in DEME-TFSA. In the doped DEME-TFSA-Li samples, the sigma and D values decreased with increasing salt concentration, and within the same sample generally DLisalt concentration at low temperatures. Since plots of the temperature dependence of T1 of the 1H and 7Li resonances showed T1 minima, the correlation times tauc(H) and tauc(Li) were calculated for reorientational motions of DEME and the lithium jump, respectively. At the same temperature, tauc(Li) is longer than tauc(H), suggesting that the molecular motion of DEME occurs more rapidly than the lithium jump. Combining the DLi and tauc(Li), averaged distances for the lithium jump were estimated.

  14. Determination of the diffusion coefficient of hydrogen ion in hydrogels.

    Science.gov (United States)

    Schuszter, Gábor; Gehér-Herczegh, Tünde; Szűcs, Árpád; Tóth, Ágota; Horváth, Dezső

    2017-05-17

    The role of diffusion in chemical pattern formation has been widely studied due to the great diversity of patterns emerging in reaction-diffusion systems, particularly in H + -autocatalytic reactions where hydrogels are applied to avoid convection. A custom-made conductometric cell is designed to measure the effective diffusion coefficient of a pair of strong electrolytes containing sodium ions or hydrogen ions with a common anion. This together with the individual diffusion coefficient for sodium ions, obtained from PFGSE-NMR spectroscopy, allows the determination of the diffusion coefficient of hydrogen ions in hydrogels. Numerical calculations are also performed to study the behavior of a diffusion-migration model describing ionic diffusion in our system. The method we present for one particular case may be extended for various hydrogels and diffusing ions (such as hydroxide) which are relevant e.g. for the development of pH-regulated self-healing mechanisms and hydrogels used for drug delivery.

  15. Contribution to the evaluation of diffusion coefficients in plasmas containing argon and fluorine

    International Nuclear Information System (INIS)

    Novakovic, N V

    2006-01-01

    The theoretical values of the numerical evaluation of the electron and ion diffusion coefficients in plasmas from mixtures of argon and fluorine are presented. The temperature dependence of the diffusion coefficients for low-pressure (from 0.1 to 1.0 kPa) and low-temperature (from 500 to 5000 K) argon plasmas with 20% and 30% of added fluorine are investigated. These values are results of the applications of the specific numerical model to the evaluation plasma composition and transport coefficients in argon plasma with fluorine as additive. It is assumed that the system is kept under constant pressure and that a corresponding state of local thermodynamical equilibrium (LTE) is attained. Since the LTE can be assumed, a Maxwellian electron distribution function will be adopted. The hypothesis of LTE, which is commonly used in most of the numerical evaluations, is analysed with the modified Debye radius r D *. The binary electron and ion diffusion coefficients are calculated with the equilibrium plasma composition and with the collision frequencies. Strictly speaking, Maxwellian distribution function (in the state LTE) is not valid for low pressure, but in this case with the aid of the modified Debye radius, a Maxwellian f e M is assumed correctly. It is shown that the electron diffusion coefficients are about four orders of magnitude larger than the corresponding overall diffusion coefficients of ions. Both diffusion coefficients are lower in argon plasma with 30% than with 20% of fluorine additives, in the whole temperature range examined

  16. Determination of ion diffusion coefficients by the electromigration method

    International Nuclear Information System (INIS)

    Bonchev, G.D.; Milanov, M.V.; Bozhikov, G.A.; Ivanov, P.I.; Priemyshev, A.N.; Maslov, O.D.; Dmitriev, S.N.

    2003-01-01

    An electrophoretic method for measuring ion diffusion coefficients in aqueous solutions is developed. The value of the diffusion coefficient can be determined from the linear relationship between the square standard deviation of the electrophoretic zone and the time from the start of the diffusion process. Using the device for horizontal zone electrophoresis in a free electrolyte, a series of diffusion experiments are performed with no-carrier-added radionuclides in microconcentrations (10 -9 - 10 -10 M). Diffusion coefficients of 111 In(III), 175 Hf(IV) and 237 Pu(VI) ions at 25 0 C are determined in nitric acid media. Simultaneous determination of the diffusion coefficient and electrophoretic mobility allows one to calculate the effective charge of the investigated ions in accordance with the Nernst-Einstein law

  17. Verifying reciprocal relations for experimental diffusion coefficients in multicomponent mixtures

    DEFF Research Database (Denmark)

    Medvedev, Oleg; Shapiro, Alexander

    2003-01-01

    into Onsager coefficients and a subsequent symmetry check make it possible to evaluate different thermodynamic models with regard to their possibility of being used for prediction of the transport properties. We performed several checks of this kind for ternary mixtures of hydrocarbons and alcohols, where......The goal of the present study is to verify the agreement of the available data on diffusion in ternary mixtures with the theoretical requirement of linear non-equilibrium thermodynamics consisting in symmetry of the matrix of the phenomenological coefficients. A common set of measured diffusion...... diffusion coefficients into Onsager coefficients for a non-ideal mixture involves derivatives of the chemical potentials and, thus, should be based on a certain thermodynamic model (cubic equation of state (EoS), an activity coefficient model, etc.). Transformation of the Fickian diffusion coefficients...

  18. Application of numerical inverse method in calculation of composition-dependent interdiffusion coefficients in finite diffusion couples

    DEFF Research Database (Denmark)

    Liu, Yuanrong; Chen, Weimin; Zhong, Jing

    2017-01-01

    The previously developed numerical inverse method was applied to determine the composition-dependent interdiffusion coefficients in single-phase finite diffusion couples. The numerical inverse method was first validated in a fictitious binary finite diffusion couple by pre-assuming four standard ...

  19. Maxwell-Stefan diffusion coefficient estimation for ternary systems: an ideal ternary alcohol system.

    Science.gov (United States)

    Allie-Ebrahim, Tariq; Zhu, Qingyu; Bräuer, Pierre; Moggridge, Geoff D; D'Agostino, Carmine

    2017-06-21

    The Maxwell-Stefan model is a popular diffusion model originally developed to model diffusion of gases, which can be considered thermodynamically ideal mixtures, although its application has been extended to model diffusion in non-ideal liquid mixtures as well. A drawback of the model is that it requires the Maxwell-Stefan diffusion coefficients, which are not based on measurable quantities but they have to be estimated. As a result, numerous estimation methods, such as the Darken model, have been proposed to estimate these diffusion coefficients. However, the Darken model was derived, and is only well defined, for binary systems. This model has been extended to ternary systems according to two proposed forms, one by R. Krishna and J. M. van Baten, Ind. Eng. Chem. Res., 2005, 44, 6939-6947 and the other by X. Liu, T. J. H. Vlugt and A. Bardow, Ind. Eng. Chem. Res., 2011, 50, 10350-10358. In this paper, the two forms have been analysed against the ideal ternary system of methanol/butan-1-ol/propan-1-ol and using experimental values of self-diffusion coefficients. In particular, using pulsed gradient stimulated echo nuclear magnetic resonance (PGSTE-NMR) we have measured the self-diffusion coefficients in various methanol/butan-1-ol/propan-1-ol mixtures. The experimental values of self-diffusion coefficients were then used as the input data required for the Darken model. The predictions of the two proposed multicomponent forms of this model were then compared to experimental values of mutual diffusion coefficients for the ideal alcohol ternary system. This experimental-based approach showed that the Liu's model gives better predictions compared to that of Krishna and van Baten, although it was only accurate to within 26%. Nonetheless, the multicomponent Darken model in conjunction with self-diffusion measurements from PGSTE-NMR represents an attractive method for a rapid estimation of mutual diffusion in multicomponent systems, especially when compared to exhaustive

  20. Diffusion measurements in binary liquid mixtures by Raman spectroscopy

    DEFF Research Database (Denmark)

    Berg, Rolf W.; Hansen, Susanne Brunsgaard; Shapiro, Alexander

    2007-01-01

    It is shown that Raman spectroscopy allows determination of the molar fractions in mixtures subjected to molecular diffusion. Spectra of three binary systems, benzene/n-hexane, benzene/cyclohexane, and benzene/ acetone, were obtained during vertical (exchange) diffusion at several different heights...

  1. Imaging and assessment of diffusion coefficients by magnetic resonance

    International Nuclear Information System (INIS)

    Tintera, J.; Dezortova, M.; Hajek, M.; Fitzek, C.

    1999-01-01

    The problem of assessment of molecular diffusion by magnetic resonance is highlighted and some typical applications of diffusion imaging in the diagnosis, e.g., of cerebral ischemia, changes in patients with phenylketonuria or multiple sclerosis are discussed. The images were obtained by using diffusion weighted spin echo Echo-Planar Imaging sequence with subsequent correction of the geometrical distortion of the images and calculation of the Apparent Diffusion Coefficient map

  2. Vertical diffuse attenuation coefficient (Kd) based optical ...

    Indian Academy of Sciences (India)

    The optical classification of the different water types provides vital input for studies related to primary productivity, water clarity and determination of euphotic depth. Image data of the IRS- P3 MOS-B, for Path 90 of 27th February, 1998 was used for deriving vertical diffuse attenuation Coeffcient () and an optical ...

  3. A data-drive analysis for heavy quark diffusion coefficient

    Science.gov (United States)

    Xu, Yingru; Nahrgang, Marlene; Cao, Shanshan; Bernhard, Jonah E.; Bass, Steffen A.

    2018-02-01

    We apply a Bayesian model-to-data analysis on an improved Langevin framework to estimate the temperature and momentum dependence of the heavy quark diffusion coefficient in the quark-gluon plasma (QGP). The spatial diffusion coefficient is found to have a minimum around 1-3 near Tc in the zero momentum limit, and has a non-trivial momentum dependence. With the estimated diffusion coefficient, our improved Langevin model is able to simultaneously describe the D-meson RAA and v2 in three different systems at RHIC and the LHC.

  4. Molecular dynamics simulations of the penetration lengths: application within the fluctuation theory for diffusion coefficients

    DEFF Research Database (Denmark)

    Galliero, Guillaume; Medvedev, Oleg; Shapiro, Alexander

    2005-01-01

    A 322 (2004) 151). In the current study, a fast molecular dynamics scheme has been developed to determine the values of the penetration lengths in Lennard-Jones binary systems. Results deduced from computations provide a new insight into the concept of penetration lengths. It is shown for four different...... binary liquid mixtures of non-polar components that computed penetration lengths, for various temperatures and compositions, are consistent with those deduced from experiments in the framework of the formalism of the fluctuation theory. Moreover, the mutual diffusion coefficients obtained from a coupled...

  5. The temperature variation of hydrogen diffusion coefficients in metal alloys

    Science.gov (United States)

    Danford, M. D.

    1990-01-01

    Hydrogen diffusion coefficients were measured as a function of temperature for a few metal alloys using an electrochemical evolution technique. Results from these measurements are compared to those obtained by the time-lag method. In all cases, diffusion coefficients obtained by the electrochemical method are larger than those by the time-lag method by an order of magnitude or more. These differences are attributed mainly to hydrogen trapping.

  6. Value of apparent diffusion coefficient (ADC) in evaluating response ...

    African Journals Online (AJOL)

    Objective. To determine whether the apparent diffusion coefficient (ADC) value obtained by diffusion-weighted magnetic resonance imaging (DW-MRI) can be used as a reliable detector of response of carcinoma of the cervix treated with chemoradiotherapy, compared with conventional. T2-weighted MRI. Design.

  7. Methods for measuring diffusion coefficients of radon in building materials

    NARCIS (Netherlands)

    Cozmuta, [No Value; van der Graaf, ER

    2001-01-01

    Two methods for determining the Rn-222 diffusion coefficient in concrete are presented. Experimentally, the flush and adsorption technique to measure radon release rates underlines both methods. Theoretically, the first method was developed fur samples of cubical geometry. The radon diffusion

  8. Calculation of ternary interdiffusion coefficients using a single diffusion couple

    Czech Academy of Sciences Publication Activity Database

    Čermák, Jiří; Rothová, Věra

    2016-01-01

    Roč. 54, č. 5 (2016), s. 305-314 ISSN 0023-432X R&D Projects: GA MŠk(CZ) ED1.1.00/02.0068 Institutional support: RVO:68081723 Keywords : diffusion * interdiffusion * ternary alloys * ternary diffusion coefficients Subject RIV: BJ - Thermodynamic s Impact factor: 0.366, year: 2016

  9. Calculation of self-diffusion coefficients in iron

    Directory of Open Access Journals (Sweden)

    Baohua Zhang

    2014-01-01

    Full Text Available On the basis of available P-V-T equation of state of iron, the temperature and pressure dependence of self-diffusion coefficients in iron polymorphs (α, δ, γ and ɛ phases have been successfully reproduced in terms of the bulk elastic and expansivity data by means of a thermodynamical model that interconnects point defects parameters with bulk properties. The calculated diffusion parameters, such as self-diffusion coefficient, activation energy and activation volume over a broad temperature range (500-2500 K and pressure range (0-100 GPa, compare favorably well with experimental or theoretical ones when the uncertainties are considered.

  10. Comparison of field-measured radon diffusion coefficients with laboratory-measured coefficients

    International Nuclear Information System (INIS)

    Lepel, E.A.; Silker, W.B.; Thomas, V.W.; Kalkwarf, D.R.

    1983-04-01

    Experiments were conducted to compare radon diffusion coefficients determined for 0.1-m depths of soils by a steady-state method in the laboratory and diffusion coefficients evaluated from radon fluxes through several-fold greater depths of the same soils covering uranium-mill tailings. The coefficients referred to diffusion in the total pore volume of the soils and are equivalent to values for the quantity, D/P, in the Generic Environmental Impact Statement on Uranium Milling prepared by the US Nuclear Regulatory Commission. Two soils were tested: a well-graded sand and an inorganic clay of low plasticity. For the flux evaluations, radon was collected by adsorption on charcoal following passive diffusion from the soil surface and also from air recirculating through an aluminum tent over the soil surface. An analysis of variance in the flux evaluations showed no significant difference between these two collection methods. Radon diffusion coefficients evaluated from field data were statistically indistinguishable, at the 95% confidence level, from those measured in the laboratory; however, the low precision of the field data prevented a sensitive validation of the laboratory measurements. From the field data, the coefficients were calculated to be 0.03 +- 0.03 cm 2 /s for the sand cover and 0.0036 +- 0.0004 cm 2 /s for the clay cover. The low precision in the coefficients evaluated from field data was attributed to high variation in radon flux with time and surface location at the field site

  11. Determining Pitch-angle Diffusion Coefficients from Test Particle Simulations

    Science.gov (United States)

    Ivascenko, Alex; Lange, Sebastian; Spanier, Felix; Vainio, Rami

    2016-12-01

    The transport and acceleration of charged particles in turbulent media are topics of great interest in space physics and interstellar astrophysics. These processes are dominated by the scattering of particles off magnetic irregularities. The scattering process itself is usually described by small-angle scattering, with the pitch-angle coefficient {D}μ μ playing a major role. Since the diffusion coefficient {D}μ μ can be determined analytically only for the approximation of quasilinear theory, the determination of this coefficient from numerical simulations has become more important. So far these simulations have yielded particle tracks for small-scale scattering, which can then be interpreted using the running diffusion coefficients. This method has a limited range of validity. This paper presents two new methods that allow for the calculation of the pitch-angle diffusion coefficient from numerical simulations. These methods no longer analyze particle trajectories and instead examine the change of particle distribution functions. It is shown that these methods provide better resolved results and allow for the analysis of strong turbulence. The application of these methods to Monte Carlo simulations of particle scattering and hybrid MHD-particle simulations is presented. Both analysis methods are able to recover the diffusion coefficients used as input for the Monte Carlo simulations and provide better results in MHD simulations, especially for stronger turbulence.

  12. Spatial Mapping of Translational Diffusion Coefficients Using Diffusion Tensor Imaging: A Mathematical Description.

    Science.gov (United States)

    Shetty, Anil N; Chiang, Sharon; Maletic-Savatic, Mirjana; Kasprian, Gregor; Vannucci, Marina; Lee, Wesley

    2014-01-01

    In this article, we discuss the theoretical background for diffusion weighted imaging and diffusion tensor imaging. Molecular diffusion is a random process involving thermal Brownian motion. In biological tissues, the underlying microstructures restrict the diffusion of water molecules, making diffusion directionally dependent. Water diffusion in tissue is mathematically characterized by the diffusion tensor, the elements of which contain information about the magnitude and direction of diffusion and is a function of the coordinate system. Thus, it is possible to generate contrast in tissue based primarily on diffusion effects. Expressing diffusion in terms of the measured diffusion coefficient (eigenvalue) in any one direction can lead to errors. Nowhere is this more evident than in white matter, due to the preferential orientation of myelin fibers. The directional dependency is removed by diagonalization of the diffusion tensor, which then yields a set of three eigenvalues and eigenvectors, representing the magnitude and direction of the three orthogonal axes of the diffusion ellipsoid, respectively. For example, the eigenvalue corresponding to the eigenvector along the long axis of the fiber corresponds qualitatively to diffusion with least restriction. Determination of the principal values of the diffusion tensor and various anisotropic indices provides structural information. We review the use of diffusion measurements using the modified Stejskal-Tanner diffusion equation. The anisotropy is analyzed by decomposing the diffusion tensor based on symmetrical properties describing the geometry of diffusion tensor. We further describe diffusion tensor properties in visualizing fiber tract organization of the human brain.

  13. Mutual diffusion of binary liquid mixtures containing methanol, ethanol, acetone, benzene, cyclohexane, toluene, and carbon tetrachloride

    Energy Technology Data Exchange (ETDEWEB)

    Guevara-Carrion, Gabriela; Janzen, Tatjana; Muñoz-Muñoz, Y. Mauricio; Vrabec, Jadran, E-mail: jadran.vrabec@uni-paderborn.de [Thermodynamics and Energy Technology, University of Paderborn, 33098 Paderborn (Germany)

    2016-03-28

    Mutual diffusion coefficients of all 20 binary liquid mixtures that can be formed out of methanol, ethanol, acetone, benzene, cyclohexane, toluene, and carbon tetrachloride without a miscibility gap are studied at ambient conditions of temperature and pressure in the entire composition range. The considered mixtures show a varying mixing behavior from almost ideal to strongly non-ideal. Predictive molecular dynamics simulations employing the Green-Kubo formalism are carried out. Radial distribution functions are analyzed to gain an understanding of the liquid structure influencing the diffusion processes. It is shown that cluster formation in mixtures containing one alcoholic component has a significant impact on the diffusion process. The estimation of the thermodynamic factor from experimental vapor-liquid equilibrium data is investigated, considering three excess Gibbs energy models, i.e., Wilson, NRTL, and UNIQUAC. It is found that the Wilson model yields the thermodynamic factor that best suits the simulation results for the prediction of the Fick diffusion coefficient. Four semi-empirical methods for the prediction of the self-diffusion coefficients and nine predictive equations for the Fick diffusion coefficient are assessed and it is found that methods based on local composition models are more reliable. Finally, the shear viscosity and thermal conductivity are predicted and in most cases favorably compared with experimental literature values.

  14. Oxygen transport in waterlogged soils, Part II. Diffusion coefficients

    International Nuclear Information System (INIS)

    Obando Moncayo, F.H.

    2004-01-01

    Several equations are available for Oxygen Transport in Waterlogged Soils and have been used for soils and plants. All of them are some form of first Fick's law as given by dQ = - DA(dc/dx)/dt. This equation illustrates some important aspects of aeration in waterlogged soils; first, D is a property of the medium and the gas, and is affected by temperature T. Likewise, the amount of diffusing substance dQ in dt is a direct function of the cross sectional area A and inversely proportional to the distance x. In fact, increasing the water content of air-dry soil, drastically decreases A and creates a further resistance for the flow of oxygen through water films around root plants, soil micro organisms and soil aggregates. The solid phase is also limiting the cross-section of surface of the free gaseous diffusion and the length and tortuosity of diffusion path in soil. In most of cases, soil gas porosity and tortuosity of soil voids are expressed in the equations of diffusion as a broad 'diffusion coefficient' (apparent coefficient diffusion). The process of soil respiration is complicated, involves many parameters, and is difficult to realistically quantify. With regard to the oxygen supply, it is convenient to distinguish macro and micro models, and hence, the flux of oxygen is assumed to have two steps. The first step is related to oxygen diffusion from the atmosphere and the air-filled porosity. The second step is related to the oxygen diffusion through water-films in and around plant roots, soil micro organisms and aggregates. Because of these models we obtain coefficients of macro or micro diffusion, rates of macro or micro diffusion, etc. In the macro diffusion process oxygen is transferred in the soil profile, mainly from the soil surface to a certain depth of the root zone, while micro diffusion deals with the flux over very short distances. Both processes, macro and micro diffusion are highly influenced by soil water content. Of course, if water is added to

  15. Optimal estimation of diffusion coefficients from single-particle trajectories

    DEFF Research Database (Denmark)

    Vestergaard, Christian L.; Blainey, Paul C.; Flyvbjerg, Henrik

    2014-01-01

    How does one optimally determine the diffusion coefficient of a diffusing particle from a single-time-lapse recorded trajectory of the particle? We answer this question with an explicit, unbiased, and practically optimal covariance-based estimator (CVE). This estimator is regression-free and is far...... substrate, the CVE is biased by substrate motion. However, given some long time series and a substrate under some tension, an extended MLE can separate particle diffusion on the substrate from substrate motion in the laboratory frame. This provides benchmarks that allow removal of bias caused by substrate...

  16. ORIGINAL ARTICLE Value of apparent diffusion coefficient (ADC) in ...

    African Journals Online (AJOL)

    and National Hospital Complex, in Bloemfontein. Women of all ages. Value of apparent diffusion coefficient (ADC) in evaluating response of carcinoma of the cervix treated with chemoradiotherapy. A le Roux, F Gebremariam, W Harmse. Department of Diagnostic Radiology, Faculty of Health Sciences, University of the Free ...

  17. Ionic conductivity and diffusion coefficient of barium-chloride-based ...

    Indian Academy of Sciences (India)

    Home; Journals; Bulletin of Materials Science; Volume 40; Issue 4. Ionic conductivity and diffusion coefficient of barium-chloride-based polymer electrolyte with poly(vinyl alcohol)–poly(4-styrenesulphonic acid) polymer complex. MAYANK PANDEY GIRISH M JOSHI NARENDRA NATH GHOSH. Volume 40 Issue 4 August ...

  18. Ionic conductivity and diffusion coefficient of barium-chloride-based ...

    Indian Academy of Sciences (India)

    2017-07-26

    Jul 26, 2017 ... Therefore this polymer electrolyte can be further studied for the development of electrochemical device applications. Keywords. Polymer electrolytes; impedance spectroscopy; diffusion coefficient; ionic conductivity. 1. Introduction .... The structural characterization of BaCl2-doped polymer elec- trolytes was ...

  19. Pressure drop coefficient of laminar Newtonian flow in axisymmetric diffusers

    International Nuclear Information System (INIS)

    Rosa, S.; Pinho, F.T.

    2006-01-01

    The laminar flow of Newtonian fluids in axisymmetric diffusers has been numerically investigated to evaluate the pressure-loss coefficient as a function of Reynolds number, diffusion angle and expansion ratio. The numerical simulations were carried out with a finite-volume based code using non-orthogonal collocated grids and second order accurate differencing schemes to discretize all terms of the transport equations. The calculations were carried out for Reynolds numbers between 2 and 200, diffusion angles from 0 deg. to 90 deg. and expansion ratios of 1.5 and 2 and the data are presented in tabular form and as correlations. A simplified 1D theoretical analysis helped explain the various contributions to the loss coefficient and its difference relative to the reversible pressure variation due to differences between the actual and fully developed friction losses, distortions of the velocity profiles and pressure non-uniformity upstream and downstream of the expansion section

  20. Variable Eddington factors and flux-limiting diffusion coefficients

    International Nuclear Information System (INIS)

    Whalen, P.P.

    1982-01-01

    Variable Eddington factors and flux limiting diffusion coefficients arise in two common techniques of closing the moment equations of transport. The first two moment equations of the full transport equation are still frequently used to solve many problems of radiative or particle transport. An approximate analysis, developed by Levermore, exhibits the relation between the coefficients of the two different techniques. This analysis is described and then used to test the validity of several commonly used flux limiters and Eddington factors. All of the ad-hoc flux limiters have limited validity. All of the variable Eddington factors derived from some underlying description of the angular distribution function are generally valid. The use of coefficients from Minerbo's elegant maximum entropy Eddington factor analysis is suggested for use in either flux limited diffusion or variable Eddington factor equations

  1. The viscous slip coefficient for a binary gas mixture

    International Nuclear Information System (INIS)

    Knackfuss, Rosenei F.

    2009-01-01

    For a moderately small rarefaction, the Navier-Stokes equations are associated with of the slip boundary condition, i e the velocity of the gas on the surface is different from zero at the surface, but its tangential component, depends on the profile distribution of velocity and temperature near the surface. The slip for the velocity profile near the surface is determined by the viscous slip coefficient. The viscous slip coefficient can be determined solving the equation of the Boltzmann or the kinetic equations which are simplified forms of Boltzmann equation with respect to the operator of collision. For this reason, in this work is presented the derivation of the solution of the viscous-slip problem for the mixtures of two noble gases, based on the McCormack model that is developed in terms of an analytical version of the discrete ordinates method has been applied with excellent results, to derive solutions to several problems in rarefied gas dynamics. To complete the problem, include the gas-surface interaction, based on the model of Cercignani-Lampis, which, unlike the model of Maxwell, has two accommodation coefficients: the coefficient of accommodation of tangential moment and the energy accommodation coefficient kinetics due to normal component of velocity. (author)

  2. Bond lifetime and diffusion coefficient in colloids with short-range interactions.

    Science.gov (United States)

    Ndong Mintsa, E; Germain, Ph; Amokrane, S

    2015-03-01

    We use molecular dynamics simulations to study the influence of short-range structures in the interaction potential between hard-sphere-like colloidal particles. Starting from model potentials and effective potentials in binary mixtures computed from the Ornstein-Zernike equations, we investigate the influence of the range and strength of a possible tail beyond the usual core repulsion or the presence of repulsive barriers. The diffusion coefficient and mean "bond" lifetimes are used as indicators of the effect of this structure on the dynamics. The existence of correlations between the variations of these quantities with the physical parameters is discussed to assess the interpretation of dynamics slowing down in terms of long-lived bonds. We also discuss the question of a universal behaviour determined by the second virial coefficient B ((2)) and the interplay of attraction and repulsion. While the diffusion coefficient follows the B ((2)) law for purely attractive tails, this is no longer true in the presence of repulsive barriers. Furthermore, the bond lifetime shows a dependence on the physical parameters that differs from that of the diffusion coefficient. This raises the question of the precise role of bonds on the dynamics slowing down in colloidal gels.

  3. An axisymmetric diffusion experiment for the determination of diffusion and sorption coefficients of rock samples.

    Science.gov (United States)

    Takeda, M; Hiratsuka, T; Ito, K; Finsterle, S

    2011-04-25

    Diffusion anisotropy is a critical property in predicting migration of substances in sedimentary formations with very low permeability. The diffusion anisotropy of sedimentary rocks has been evaluated mainly from laboratory diffusion experiments, in which the directional diffusivities are separately estimated by through-diffusion experiments using different rock samples, or concurrently by in-diffusion experiments in which only the tracer profile in a rock block is measured. To estimate the diffusion anisotropy from a single rock sample, this study proposes an axisymmetric diffusion test, in which tracer diffuses between a cylindrical rock sample and a surrounding solution reservoir. The tracer diffusion between the sample and reservoir can be monitored from the reservoir tracer concentrations, and the tracer profile could also be obtained after dismantling the sample. Semi-analytical solutions are derived for tracer concentrations in both the reservoir and sample, accounting for an anisotropic diffusion tensor of rank two as well as the dilution effects from sampling and replacement of reservoir solution. The transient and steady-state analyses were examined experimentally and numerically for different experimental configurations, but without the need for tracer profiling. These experimental configurations are tested for in- and out-diffusion experiments using Koetoi and Wakkanai mudstones and Shirahama sandstone, and are scrutinized by a numerical approach to identify favorable conditions for parameter estimation. The analysis reveals the difficulty in estimating diffusion anisotropy; test configurations are proposed for enhanced identifiability of diffusion anisotropy. Moreover, it is demonstrated that the axisymmetric diffusion test is efficient in obtaining the sorption parameter from both steady-state and transient data, and in determining the effective diffusion coefficient if isotropic diffusion is assumed. Moreover, measuring reservoir concentrations in an

  4. An asixymmetric diffusion experiment for the determination of diffusion and sorption coefficients of rock samples

    Energy Technology Data Exchange (ETDEWEB)

    Takeda, M.; Hiratsuka, T.; Ito, K.; Finsterle, S.

    2011-02-01

    Diffusion anisotropy is a critical property in predicting migration of substances in sedimentary formations with very low permeability. The diffusion anisotropy of sedimentary rocks has been evaluated mainly from laboratory diffusion experiments, in which the directional diffusivities are separately estimated by through-diffusion experiments using different rock samples, or concurrently by in-diffusion experiments in which only the tracer profile in a rock block is measured. To estimate the diffusion anisotropy from a single rock sample, this study proposes an axisymmetric diffusion test, in which tracer diffuses between a cylindrical rock sample and a surrounding solution reservoir. The tracer diffusion between the sample and reservoir can be monitored from the reservoir tracer concentrations, and the tracer profile could also be obtained after dismantling the sample. Semi-analytical solutions are derived for tracer concentrations in both the reservoir and sample, accounting for an anisotropic diffusion tensor of rank two as well as the dilution effects from sampling and replacement of reservoir solution. The transient and steady-state analyses were examined experimentally and numerically for different experimental configurations, but without the need for tracer profiling. These experimental configurations are tested for in- and out-diffusion experiments using Koetoi and Wakkanai mudstones and Shirahama sandstone, and are scrutinized by a numerical approach to identify favorable conditions for parameter estimation. The analysis reveals the difficulty in estimating diffusion anisotropy; test configurations are proposed for enhanced identifiability of diffusion anisotropy. Moreover, it is demonstrated that the axisymmetric diffusion test is efficient in obtaining the sorption parameter from both steady-state and transient data, and in determining the effective diffusion coefficient if isotropic diffusion is assumed. Moreover, measuring reservoir concentrations in an

  5. Selective Adsorption and Selective Transport Diffusion of CO2-CH4 Binary Mixture in Coal Ultramicropores.

    Science.gov (United States)

    Zhao, Yongliang; Feng, Yanhui; Zhang, Xinxin

    2016-09-06

    The adsorption and diffusion of the CO2-CH4 mixture in coal and the underlying mechanisms significantly affect the design and operation of any CO2-enhanced coal-bed methane recovery (CO2-ECBM) project. In this study, bituminous coal was fabricated based on the Wiser molecular model and its ultramicroporous parameters were evaluated; molecular simulations were established through Grand Canonical Monte Carlo (GCMC) and Molecular Dynamic (MD) methods to study the effects of temperature, pressure, and species bulk mole fraction on the adsorption isotherms, adsorption selectivity, three distinct diffusion coefficients, and diffusivity selectivity of the binary mixture in the coal ultramicropores. It turns out that the absolute adsorption amount of each species in the mixture decreases as temperature increases, but increases as its own bulk mole fraction increases. The self-, corrected, and transport diffusion coefficients of pure CO2 and pure CH4 all increase as temperature or/and their own bulk mole fractions increase. Compared to CH4, the adsorption and diffusion of CO2 are preferential in the coal ultramicropores. Adsorption selectivity and diffusivity selectivity were simultaneously employed to reveal that the optimal injection depth for CO2-ECBM is 800-1000 m at 308-323 K temperature and 8.0-10.0 MPa.

  6. Apparent diffusion coefficient correlation with oesophageal tumour stroma and angiogenesis

    International Nuclear Information System (INIS)

    Aoyagi, Tomoyoshi; Shuto, Kiyohiko; Okazumi, Shinichi; Hayano, Kohichi; Satoh, Asami; Saitoh, Hiroshige; Shimada, Hideaki; Nabeya, Yoshihiro; Matsubara, Hisahiro; Kazama, Toshiki

    2012-01-01

    Because diffusion-weighted imaging (DWI) can predict the prognosis of patients with oesophageal squamous cell carcinoma (ESCC), we hypothesised that apparent diffusion coefficient (ADC) values might be correlated with the collagen content and tumour angiogenesis. The purpose of this study was to determine the correlation between ADC values of ESCC before treatment and oesophageal tumour stroma and angiogenesis. Seventeen patients with ESCC were enrolled. The ADC values were calculated from the DWI score. Seventeen patients who had undergone oesophagectomy were analysed for tumour stroma, vascular endothelial growth factor (VEGF) and CD34. Tissue collagen was stained with azocarmine and aniline blue to quantitatively analyse the extracellular matrix in cancer stroma. Tissues were stained with VEGF and CD34 to analyse the angiogenesis. The ADC values decreased with stromal collagen growth. We found a negative correlation between the tumour ADC and the amount of stromal collagen (r = -0.729, P = 0.001), i.e. the ADC values decreased with growth of VEGF. We also found a negative correlation between the ADC of the tumours and the amount of VEGF (r = 0.538, P = 0.026). Our results indicated that the ADC value may be a novel prognostic factor and contribute to the treatment of oesophageal cancer. circle Magnetic resonance apparent diffusion coefficient values inversely indicate tumour stromal collagen circle There is also negative correlation between ADCs and vascular endothelial growth factor circle ADC values may contribute to the treatment of oesophageal cancer. (orig.)

  7. Comparison of radon diffusion coefficients measured by transient-diffusion and steady-state laboratory methods

    International Nuclear Information System (INIS)

    Kalwarf, D.R.; Nielson, K.K.; Rich, D.C.; Rogers, V.C.

    1982-11-01

    A method was developed and used to determine radon diffusion coefficients in compacted soils by transient-diffusion measurements. A relative standard deviation of 12% was observed in repeated measurements with a dry soil by the transient-diffusion method, and a 40% uncertainty was determined for moistures exceeding 50% of saturation. Excellent agreement was also obtained between values of the diffusion coefficient for radon in air, as measured by the transient-diffusion method, and those in the published literature. Good agreement was also obtained with diffusion coefficients measured by a steady-state method on the same soils. The agreement was best at low moistures, averaging less than ten percent difference, but differences of up to a factor of two were observed at high moistures. The comparison of the transient-diffusion and steady-state methods at low moistures provides an excellent verification of the theoretical validity and technical accuracy of these approaches, which are based on completely independent experimental conditions, measurement methods and mathematical interpretations

  8. Apparent diffusion coefficient measurements in progressive supranuclear palsy

    Energy Technology Data Exchange (ETDEWEB)

    Ohshita, T.; Oka, M.; Imon, Y.; Yamaguchi, S.; Mimori, Y.; Nakamura, S. [Hiroshima Univ. (Japan). School of Medicine

    2000-09-01

    We measured the apparent diffusion coefficient (ADC), using diffusion-weighted imaging (DWI) and signal intensity on T2-weighted MRI in the cerebral white matter of patients with progressive supranuclear palsy (PSP) and age-matched normal subjects. In PSP, ADC in the prefrontal and precentral white matter was significantly higher than in controls. There was no significant difference in signal intensity on T2-weighted images. The ADC did correlate with signal intensity. The distribution of the elevation of ADC may be the consequence of underlying pathological changes, such as neurofibrillary tangles or glial fibrillary tangles in the cortex. Our findings suggest that ADC measurement might be useful for demonstrating subtle neuropathological changes. (orig.)

  9. Binary joint transform correlation using error-diffusion techniques

    Science.gov (United States)

    Inbar, Hanni; Marom, Emanuel; Konforti, Naim

    1993-08-01

    Optical pattern recognition techniques based on the optical joint transform correlator (JTC) scheme are attractive due to their simplicity. Recent improvements in spatial light modulators (SLM) increased the popularity of the JTC, providing means for real time operation. Using a binary SLM for the display of the Fourier spectrum, first requires binarization of the joint power spectrum distribution. Although hard-clipping is the simplest and most common binarization method used, we suggest to apply error-diffusion as an improved binarization technique. The performance of a binary JTC, whose input image is considered to contain additive zero-mean white Gaussian noise, is investigated. Various ways for nonlinearly modifying the joint power spectrum prior to the binarization step, which is based on either error-diffusion or hard-clipping techniques, are discussed. These nonlinear modifications aim at increasing the contrast of the interference fringes at the joint power spectrum plane, leading to better definition of the correlation signal. Mathematical analysis, computer simulations and experimental results are presented.

  10. Viscous slip coefficients for binary gas mixtures measured from mass flow rates through a single microtube

    OpenAIRE

    Yamaguchi, H.; Takamori, K.; Perrier, P.; Graur, I.; Matsuda, Y.; Niimi, T.

    2016-01-01

    The viscous slip coefficient for helium-argon binary gas mixture is extracted from the experimental values of the mass flow rate through a microtube. The mass flow rate is measured by the constant-volume method. The viscous slip coefficient was obtained by identifying the measured mass flow rate through a microtube with the corresponding analytical expression, which is a function of the Knudsen number. The measurements were carried out in the slip flow regime where the first-order slip bounda...

  11. Determination of the diffusion coefficient of salts in non-Newtonian liquids by the Taylor dispersion method

    Energy Technology Data Exchange (ETDEWEB)

    Mey, Paula; Varges, Priscilla R.; Mendes, Paulo R. de Souza [Dept. of Mechanical Engineering. Pontificia Universidade Catolica do RJ (PUC-Rio), RJ (Brazil)], e-mails: prvarges@puc-rio.br, pmendes@puc-rio.br

    2010-07-01

    This research looked for a method to determine the binary diffusion coefficient D of salts in liquids (especially in drilling fluids) not only accurately, but in a reasonable time. We chose to use the Taylor Dispersion Method. This technique has been used for measuring binary diffusion coefficients in gaseous, liquid and supercritical fluids, due to its simplicity and accuracy. In the method, the diffusion coefficient is determined by the analysis of the dispersion of a pulse of soluble material in a solvent flowing laminarly through a tube. This work describes the theoretical basis and the experimental requirements for the application of the Taylor Dispersion Method, emphasizing the description of our experiment. A mathematical formulation for both Newtonian and non-Newtonian fluids is presented. The relevant sources of errors are discussed. The experimental procedure and associated analysis are validated by applying the method in well known systems, such as NaCl in water.D of salts in liquids (especially in drilling fluids) not only accurately, but in a reasonable time. We chose to use the Taylor Dispersion Method. This technique has been used for measuring binary diffusion coefficients in gaseous, liquid and supercritical fluids, due to its simplicity and accuracy. In the method, the diffusion coefficient is determined by the analysis of the dispersion of a pulse of soluble material in a solvent flowing laminarly through a tube. This work describes the theoretical basis and the experimental requirements for the application of the Taylor Dispersion Method, emphasizing the description of our experiment. A mathematical formulation for both Newtonian and non-Newtonian fluids is presented. The relevant sources of errors are discussed. The experimental procedure and associated analysis are validated by applying the method in well known systems, such as NaCl in water. (author)

  12. Isotropic apparent diffusion coefficient mapping of postnatal cerebral development

    Energy Technology Data Exchange (ETDEWEB)

    Loevblad, K.O. [Unite de Neuroradiologie, Departement de Radiodiagnostic, Hopital Cantonal Universitaire HUG, 24 rue Micheli-du-Crest, Geneva 14 (Switzerland); Department of Neuroradiology, Inselspital, Bern (Switzerland); Schneider, J. [MRI Unit, Children' s Hospital, Zurich (Switzerland); Ruoss, K.; Schroth, G. [Department of Neuroradiology, Inselspital, Bern (Switzerland); Steinlin, M. [Neurology Department, Children' s Hospital, University of Bern, Bern (Switzerland); Fusch, C. [Department of Neonatology, University of Greifswald (Germany)

    2003-06-01

    Diffusion-weighted imaging (DWI) allows us to image the motion of tissue water. This has been used to demonstrate acute ischaemia. Diffusion imaging is also sensitive to water movement along neuronal tracts. Our objective was to map brain maturation in vivo using maps of apparent diffusion coefficient (ADC). We studied 22 children without neurological disease aged between 2 and 720 days. MRI was performed at 1.5 tesla. Multislice single-shot echoplanar DWI was performed at b 0 and 1000 s/mm{sup 2}. ADC maps were generated automatically and measurements were performed in the basal ganglia, frontal and temporal white matter and the pons. There was a decrease over time in water diffusion in the areas examined, most marked in the frontal (0.887-1.898 x 10-3 mm{sup 2}/s) and temporal (1.077-1.748 x 10-3 mm{sup 2}/s)lobes. There was little change, after an initial decrease, in the basal ganglia (0.690-1.336 x 10-3 mm{sup 2}/s). There was a difference in water diffusion between the anterior (0.687-1.581 x 10-3 mm{sup 2}/s) and posterior (0.533-1.393 x 10-3 mm{sup 2}/s) pons. These changes correlate well with those observed in progressive myelination: the increased water content probably reflects incomplete myelination and the decrease with time in water motion reflects the increase in myelinated brain. (orig.)

  13. Unsaturated soil moisture drying and wetting diffusion coefficient measurements in the laboratory.

    Science.gov (United States)

    2009-09-01

    ABSTRACTTransient moisture flow in an unsaturated soil in response to suction changes is controlled by the unsaturated moisture diffusion coefficient. The moisture diffusion coefficient can be determined by measuring suction profiles over time. The l...

  14. Reconstruction algorithm for error diffused halftones using binary permutation filters

    Science.gov (United States)

    Kim, Yeong-Taeg; Arce, Gonzalo R.

    1994-09-01

    This paper describes an inverse halftoning algorithm to reconstruct a continuous-tone image given its error diffused halftone. We develop a modular class of non-linear filters, denoted as a class of binary permutation filters, which can reconstruct the continuous-tone information preserving image details and edges which provide important visual cues. The proposed non- linear reconstruction algorithm is based on the space-rank ordering of the halftone samples, which is provided by the multiset permutation of the `on' pixels in a halftone observation window. By varying the space-rank order information utilized in the estimate, for a given window size, we obtain a wide range of filters. A constrained LMS type algorithm is employed to design optimal reconstruction filters which minimize the reconstruction mean squared error. We present simulations showing that the proposed class of filters is modular, robust to image source characteristics, and that the results produce high visual quality image reconstruction.

  15. Measurement of diffusion coefficient of propylene glycol in skin tissue

    Science.gov (United States)

    Genin, Vadim D.; Bashkatov, Alexey N.; Genina, Elina A.; Tuchin, Valery V.

    2015-03-01

    Optical clearing of the rat skin under the action of propylene glycol was studied ex vivo. It was found that collimated transmittance of skin samples increased, whereas weight and thickness of the samples decreased during propylene glycol penetration in skin tissue. A mechanism of the optical clearing under the action of propylene glycol is discussed. Diffusion coefficient of propylene glycol in skin tissue ex vivo has been estimated as (1.35±0.95)×10-7 cm2/s with the taking into account of kinetics of both weight and thickness of skin samples. The presented results can be useful for enhancement of many methods of laser therapy and optical diagnostics of skin diseases and localization of subcutaneous neoplasms.

  16. R package to estimate intracluster correlation coefficient with confidence interval for binary data.

    Science.gov (United States)

    Chakraborty, Hrishikesh; Hossain, Akhtar

    2018-03-01

    The Intracluster Correlation Coefficient (ICC) is a major parameter of interest in cluster randomized trials that measures the degree to which responses within the same cluster are correlated. There are several types of ICC estimators and its confidence intervals (CI) suggested in the literature for binary data. Studies have compared relative weaknesses and advantages of ICC estimators as well as its CI for binary data and suggested situations where one is advantageous in practical research. The commonly used statistical computing systems currently facilitate estimation of only a very few variants of ICC and its CI. To address the limitations of current statistical packages, we developed an R package, ICCbin, to facilitate estimating ICC and its CI for binary responses using different methods. The ICCbin package is designed to provide estimates of ICC in 16 different ways including analysis of variance methods, moments based estimation, direct probabilistic methods, correlation based estimation, and resampling method. CI of ICC is estimated using 5 different methods. It also generates cluster binary data using exchangeable correlation structure. ICCbin package provides two functions for users. The function rcbin() generates cluster binary data and the function iccbin() estimates ICC and it's CI. The users can choose appropriate ICC and its CI estimate from the wide selection of estimates from the outputs. The R package ICCbin presents very flexible and easy to use ways to generate cluster binary data and to estimate ICC and it's CI for binary response using different methods. The package ICCbin is freely available for use with R from the CRAN repository (https://cran.r-project.org/package=ICCbin). We believe that this package can be a very useful tool for researchers to design cluster randomized trials with binary outcome. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Apparent diffusion coefficient in vasogenic edema and reactive astrogliosis

    Energy Technology Data Exchange (ETDEWEB)

    Hagen, Thomas [Radiology Center, Augsburg (Germany); Ahlhelm, Frank [Saarland University Hospital, Clinic for Diagnostic and Interventional Neuroradiology, Homburg/Saar (Germany); Reiche, Werner [Institute of Radiology, Lahr (Germany)

    2007-11-15

    Distinguishing between vasogenic edema and reactive astrogliosis may be difficult in some instances. This study was performed to test the hypothesis that diffusion-weighted (DW) imaging with apparent diffusion coefficient (ADC) maps can be used to differentiate these two types of changes. The study population included 11 patients with perilesional vasogenic edema and 11 patients with gliosis examined with conventional MR imaging and DW imaging. The signal intensities of conventional pulse sequences and ADC values were calculated in regions of interest placed in the hyperintense edematous or gliotic regions and compared with those of normal-appearing white matter. Signal intensity ratios and ADC values in gliosis were compared with those in vasogenic edema using the Mann-Whitney U-test. While considerable overlap was present for signal intensity ratios on conventional MR images, areas of gliosis demonstrated significantly higher ADC values (1.76 {+-} 0.09 x 10{sup -3} mm{sup 2}/s) than areas of vasogenic edema (1.35 {+-} 0.06 x 10{sup -3} mm{sup 2}/s; P < 0.0001) without overlap. ADC values are helpful in differentiating reactive gliosis from vasogenic edema. (orig.)

  18. Apparent diffusion coefficient in vasogenic edema and reactive astrogliosis.

    Science.gov (United States)

    Hagen, Thomas; Ahlhelm, Frank; Reiche, Werner

    2007-11-01

    Distinguishing between vasogenic edema and reactive astrogliosis may be difficult in some instances. This study was performed to test the hypothesis that diffusion-weighted (DW) imaging with apparent diffusion coefficient (ADC) maps can be used to differentiate these two types of changes. The study population included 11 patients with perilesional vasogenic edema and 11 patients with gliosis examined with conventional MR imaging and DW imaging. The signal intensities of conventional pulse sequences and ADC values were calculated in regions of interest placed in the hyperintense edematous or gliotic regions and compared with those of normal-appearing white matter. Signal intensity ratios and ADC values in gliosis were compared with those in vasogenic edema using the Mann-Whitney U-test. While considerable overlap was present for signal intensity ratios on conventional MR images, areas of gliosis demonstrated significantly higher ADC values (1.76 +/- 0.09 x 10(-3) mm(2)/s) than areas of vasogenic edema (1.35 +/- 0.06 x 10(-3) mm(2)/s; P gliosis from vasogenic edema.

  19. Measurement of the thermal conductivity and heat transfer coefficient of a binary bed of beryllium pebbles

    Energy Technology Data Exchange (ETDEWEB)

    Donne, M.D.; Piazza, G. [Forschungszentrum Karlsruhe GmbH Technik und Umwelt (Germany). Inst. fuer Neutronenphysik und Reaktortechnik; Goraieb, A.; Sordon, G.

    1998-01-01

    The four ITER partners propose to use binary beryllium pebble bed as neutron multiplier. Recently this solution has been adopted for the ITER blanket as well. In order to study the heat transfer in the blanket the effective thermal conductivity and the wall heat transfer coefficient of the bed have to be known. Therefore at Forschungszentrum Karlsruhe heat transfer experiments have been performed with a binary bed of beryllium pebbles and the results have been correlated expressing thermal conductivity and wall heat transfer coefficients as a function of temperature in the bed and of the difference between the thermal expansion of the bed and of that of the confinement walls. The comparison of the obtained correlations with the data available from the literature show a quite good agreement. (author)

  20. A theoretical framework for quantitatively characterizing sound field diffusion based on scattering coefficient and absorption coefficient of walls.

    Science.gov (United States)

    Hanyu, Toshiki

    2010-09-01

    This paper describes the development of a theoretical framework for quantitatively characterizing sound field diffusion based on scattering coefficient and absorption coefficient of walls. The concepts of equivalent scattering area, equivalent scatter reflection area, average scattering coefficient and average scatter reflection coefficient are introduced in order to express all walls' capability of scatter in a room. Using these concepts and the mean free path, scatter-to-absorption ratio, mean scatter time and diffusion time are defined in order to evaluate degree of diffusion of a space. Furthermore the effect of spatial scattering objects to sound field diffusion is formulated. In addition the time variation of specular and scattered components in a room impulse response is formulated. The verification of these characterization methods was performed with computer simulations based on the sound ray tracing method. The results supported that the ideas presented are basically valid.

  1. Effective diffusion coefficient of radon in concrete, theory and method for field measurements

    International Nuclear Information System (INIS)

    Culot, M.V.J.; Olson, H.G.; Schiager, K.J.

    1976-01-01

    A linear diffusion model serves as the basis for determination of an effective radon diffusion coefficient in concrete. The coefficient was needed to later allow quantitative prediction of radon accumulation within and behind concrete walls after application of an impervious radon barrier. A resolution of certain discrepancies noted in the literature in the use of an effective diffusion coefficient to model diffusion of a radioactive gas through a porous medium is suggested. An outline of factors expected to affect the concrete physical structure and the effective diffusion coefficient of radon through it is also presented. Finally, a field method for evaluating effective radon diffusion coefficients in concrete is proposed and results of measurements performed on a concrete foundation wall are compared with similar published values of gas diffusion coefficients in concrete. (author)

  2. On the Origin of Quantum Diffusion Coefficient and Quantum Potential

    Science.gov (United States)

    Gupta, Aseem

    2016-03-01

    Synchronizability of space and time experiences between different inhabitants of a spacetime is abstracted as a fundamental premise of Classical physics. Absence thereof i.e. desynchronization between space and time experiences of a system under study and the observer is then studied for a single dimension single particle system. Desynchronization fundamentally makes probability concepts enter physics ab-initio and not as secondary tools to deal with situations wherein incomplete information in situation following perfectly deterministic dynamics demands its introduction. Desynchronization model based on Poisson distribution of events vis-à-vis an observer, leads to expectation of particle's motion as a Brownian motion deriving Nelson's quantum diffusion coefficient naturally, without needing to postulate it. This model also incorporates physical effects akin to those of Bohm's Quantum Potential, again without needing any sub-quantum medium. Schrodinger's equation is shown to be derivable incorporating desynchronization only of space while Quantum Field Theory is shown to model desynchronization of time as well. Fundamental suggestion of the study is that it is desynchronization that is at the root of quantum phenomena rather than sub-micro scales of spacetime. Absence of possibility of synchronization between system's space and time and those of observer is studied. Mathematical modeling of desynchronized evolution explains some intriguing aspects of Quantum Mechanical theory.

  3. Discrimination of paediatric brain tumours using apparent diffusion coefficient histograms

    International Nuclear Information System (INIS)

    Bull, Jonathan G.; Clark, Christopher A.; Saunders, Dawn E.

    2012-01-01

    To determine if histograms of apparent diffusion coefficients (ADC) can be used to differentiate paediatric brain tumours. Imaging of histologically confirmed tumours with pre-operative ADC maps were reviewed (54 cases, 32 male, mean age 6.1 years; range 0.1-15.8 years) comprising 6 groups. Whole tumour ADC histograms were calculated; normalised for volume. Stepwise logistic regression analysis was used to differentiate tumour types using histogram metrics, initially for all groups and then for specific subsets. All 6 groups (5 dysembryoplastic neuroectodermal tumours, 22 primitive neuroectodermal tumours (PNET), 5 ependymomas, 7 choroid plexus papillomas, 4 atypical teratoid rhabdoid tumours (ATRT) and 9 juvenile pilocytic astrocytomas (JPA)) were compared. 74% (40/54) were correctly classified using logistic regression of ADC histogram parameters. In the analysis of posterior fossa tumours, 80% of ependymomas, 100% of astrocytomas and 94% of PNET-medulloblastoma were classified correctly. All PNETs were discriminated from ATRTs (22 PNET and 4 supratentorial ATRTs) (100%). ADC histograms are useful in differentiating paediatric brain tumours, in particular, the common posterior fossa tumours of childhood. PNETs were differentiated from supratentorial ATRTs, in all cases, which has important implications in terms of clinical management. (orig.)

  4. NON-EQUILIBRIUM MOLECULAR DYNAMICS USED TO OBTAIN SORET COEFFICIENTS OF BINARY HYDROCARBON MIXTURES

    Directory of Open Access Journals (Sweden)

    F. A. Furtado

    2015-09-01

    Full Text Available AbstractThe Boundary Driven Non-Equilibrium Molecular Dynamics (BD-NEMD method is employed to evaluate Soret coefficients of binary mixtures. Using a n-decane/n-pentane mixture at 298 K, we study several parameters and conditions of the simulation procedure such as system size, time step size, frequency of perturbation, and the undesired warming up of the system during the simulation. The Soret coefficients obtained here deviated around 20% when comparing with experimental data and with simulated results from the literature. We showed that fluctuations in composition gradients and the consequent deviations of the Soret coefficient may be due to characteristic fluctuations of the composition gradient. Best results were obtained with the smallest time steps and without using a thermostat, which shows that there is room for improvement and/or development of new BD-NEMD algorithms.

  5. Protein diffusion coefficients determined by macroscopic-gradient Rayleigh interferometry and dynamic light scattering.

    Science.gov (United States)

    Annunziata, Onofrio; Buzatu, Daniela; Albright, John G

    2005-12-20

    Dynamic light scattering (DLS) is extensively used for measuring macromolecule diffusion coefficients. Contrary to classical techniques based on macroscopic concentration gradients, DLS probes microscopic fluctuations in concentration. DLS accuracy and its concordance with macroscopic-gradient techniques remains an outstanding important issue. We measured lysozyme diffusion coefficients in aqueous salt using both DLS and Rayleigh interferometry, a highly accurate macroscopic-gradient technique. The precision of our results is unprecedented. We find that our DLS values were systematically 2% higher than interferometry values. We believe that our interferometric measurements have produced the most accurate diffusion data ever reported for a protein, providing a new standard for quality control of DLS measurements. Furthermore, by interferometry, we have determined the whole diffusion coefficient matrix required for rigorously describing lysozyme-salt coupled diffusion. For the first time, we experimentally demonstrate that DLS does not provide the protein diffusion coefficient but one eigenvalue of the diffusion coefficient matrix.

  6. Evaluation of diffusion coefficients in multicomponent mixtures by means of the fluctuation theory

    DEFF Research Database (Denmark)

    Shapiro, Alexander

    2003-01-01

    We derive general expressions for diffusion coefficients in multicomponent non-ideal gas or liquid mixtures. The derivation is based on the general statistical theory of fluctuations around an equilibrium state. The matrix of diffusion coefficients is expressed in terms of the equilibrium...... characteristics. We demonstrate on several examples that the developed theory is in agreement with the established experimental facts and dependencies for the diffusion coefficients. (C) 2002 Elsevier Science B.V. All rights reserved....

  7. Study of apparent diffusion coefficient value in the normal breastq

    International Nuclear Information System (INIS)

    Cai Shifeng

    2007-01-01

    Objective: To investigate the differences of apparent diffusion coefficient (ADC) value in normal breasts and to evaluate the correlation between ADC value and corresponding histology. Methods: Sixty-two normal breasts including 42 normal breasts of 42 patients with unilateral lesions and 20 normal breasts of 10 volunteers were studied. The ADC value of all 62 normal breasts were calculated when b value was given from 1000 to 0 s/mm 2 , 1000 to 500 s/mm 2 and 500 to 0 s/mm 2 . The MRI features of 60 normal breasts were classified into 3 types (dense, lobular-speckled, degenerative types) according to Wolf's classification and histology. Results: DWI and ADC images were different in 3 types of normal breasts because of different histologic structures. The mean ADC value of the dense type breasts was (1.70 ± 0.37) x 10 -3 mm 2 /s, the lobular-speckled type was (1.93 ± 0.46) x 10 -3 mm 2 /s and the degenerative type was (1.18 ± 0.65) x 10 -3 mm 2 /s (F=12.998, P=0.000). There were no significant differences between the dense type and the lobular-speckled type (F=2.167, P=0.147), but significant differences between the dense type and the degenerative type, the lobular-speckled type and the degenerate type (F=5.593 and 19.128; P=0.029 and 0.000). When b value decreased, the ADC value of the dense type and the lobular-speckled type increased correspondingly, but the degenerative type didn't increase apparently. Conclusion: ADC value was influenced by histologic structures in normal breasts and also was influenced by b value in the dense type and lobular-speckled type breasts. (authors)

  8. Turbulent eddy diffusion models in exposure assessment - Determination of the eddy diffusion coefficient.

    Science.gov (United States)

    Shao, Yuan; Ramachandran, Sandhya; Arnold, Susan; Ramachandran, Gurumurthy

    2017-03-01

    The use of the turbulent eddy diffusion model and its variants in exposure assessment is limited due to the lack of knowledge regarding the isotropic eddy diffusion coefficient, D T . But some studies have suggested a possible relationship between D T and the air changes per hour (ACH) through a room. The main goal of this study was to accurately estimate D T for a range of ACH values by minimizing the difference between the concentrations measured and predicted by eddy diffusion model. We constructed an experimental chamber with a spatial concentration gradient away from the contaminant source, and conducted 27 3-hr long experiments using toluene and acetone under different air flow conditions (0.43-2.89 ACHs). An eddy diffusion model accounting for chamber boundary, general ventilation, and advection was developed. A mathematical expression for the slope based on the geometrical parameters of the ventilation system was also derived. There is a strong linear relationship between D T and ACH, providing a surrogate parameter for estimating D T in real-life settings. For the first time, a mathematical expression for the relationship between D T and ACH has been derived that also corrects for non-ideal conditions, and the calculated value of the slope between these two parameters is very close to the experimentally determined value. The values of D T obtained from the experiments are generally consistent with values reported in the literature. They are also independent of averaging time of measurements, allowing for comparison of values obtained from different measurement settings. These findings make the use of turbulent eddy diffusion models for exposure assessment in workplace/indoor environments more practical.

  9. Diffusion simulation of ferric ions in dosemeter Fricke-gel with variable diffusion coefficient

    International Nuclear Information System (INIS)

    Milani, Caio Jacob; Bevilacqua, Joyce da Silva; Rodrigues Junior, Orlando

    2014-01-01

    Dosimetry using dosimeters Fricke-xylenol-Gel (FXG) allows confirmation and better understanding of radiotherapy treatments. The technique involves the evaluation of volumes irradiated by magnetic resonance imaging (MRI) or CT-optical. In both cases, the time spent between the irradiation and measurement is an important factor that directly influences the results. The quality of the images can be compromised by the mobility of ferric ions (Fe 3+), formed during the interaction of radiation with matter, increasing the uncertainty in determining the isodose. In this work, we simulated the dynamic involving ferric ions formed in one irradiated region irradiated in a two-dimensional domain with a variable diffusion coefficient. This phenomenon is modeled by a differential equation and solved numerically by an efficient algorithm that generalizes the Crank-Nicolson method. The stability and consistency of the method guarantee the convergence of the numerical solution for a predefined tolerance based in the choice of discretization steps of time and space. Different continuous functions were chosen to represent the diffusion coefficient and graphical views of the phenomenon are presented for a better understanding of the process

  10. Correlating apparent diffusion coefficients with histopathologic findings on meningiomas

    Energy Technology Data Exchange (ETDEWEB)

    Yin, Bo, E-mail: yinbo7@163.com [Department of Radiology, Huashan Hospital, Fudan University, 12 Wulumuqi Rd. Middle, Shanghai 200040 (China); Liu, Li, E-mail: llbbsy@163.com [Department of Radiology, Cancer Hospital, Fudan University, 270 Dongan Rd., Shanghai 200032 (China); Zhang, Bi Yun, E-mail: bianka0830@126.com [Department of Radiology, Huashan Hospital, Fudan University, 12 Wulumuqi Rd. Middle, Shanghai 200040 (China); Li, Yu Xin, E-mail: liyuxin76@126.com [Department of Radiology, Huashan Hospital, Fudan University, 12 Wulumuqi Rd. Middle, Shanghai 200040 (China); Li, Yuan, E-mail: ybllfd@163.com [Department of Radiology, Huashan Hospital, Fudan University, 12 Wulumuqi Rd. Middle, Shanghai 200040 (China); Geng, Dao Ying, E-mail: gengdymd@163.com [Department of Radiology, Huashan Hospital, Fudan University, 12 Wulumuqi Rd. Middle, Shanghai 200040 (China)

    2012-12-15

    Purpose: To determine whether the apparent diffusion coefficient (ADC) correlates with histopathologic findings and whether ADC values can be used to differentiate benign from atypical/malignant meningiomas. Materials and methods: MR images were reviewed retrospectively in 138 patients with meningiomas treated between September 1997 and July 2003. The ADC values were measured in the lesions and peritumoral edema, and the normalized ADC (NADC) ratios were calculated using the formula NADC = ADC of the tumor/ADC of the normal white matter. The ADC findings were compared with the histopathologic findings after resection using the World Health Organization criteria (2007). Results: Meningiomas were histologically graded as malignant (9%), atypical (14%) and benign (77%). Of the 138 meningiomas, 32 (23%) were atypical (n = 19) or malignant (n = 13), whereas 106 (77%) were typical. The mean ADC values were statistically different between typical and atypical/malignant meningiomas (0.97 ± 0.21 × 10{sup −3} mm{sup 2}/s vs 0.85 ± 0.17 × 10{sup −3} mm{sup 2}/s). The mean NADC ratios were also significantly lower in the atypical/malignant group (1.09 ± 0.23) than in the benign group (1.24 ± 0.25; P = 0.002 < 0.05). The mean ADC values and NADC ratios did not differ significantly among fibrous, meningothelial, transitional and atypical tumors (P > 0.05). The mean ADC values and NADC ratios were higher in the angiomatous and secretory subgroups than in the fibrous, meningothelial, transitional, atypical and malignant subgroups (P < 0.05). The ADC values and NADC ratios were the lowest in the malignant subgroup, and the difference between atypical and malignant meningiomas was statistically significant (P < 0.05). Conclusions: Meningioma subgroups displayed different ADC values from each other. Thus, ADC values may provide a useful supplement to the information obtained from conventional contrast-enhanced MR imaging, enhancing the ability of medical professionals to

  11. Diffusion-weighted MR and apparent diffusion coefficient in the evaluation of severe brain injury

    International Nuclear Information System (INIS)

    Nakahara, M.; Ericson, K.; Bellander, B.M.

    2001-01-01

    Purpose: To study apparent diffusion coefficient (ADC) maps in severely brain-injured patients. Material and Methods: Four deeply comatose patients with severe brain injury were investigated with single-shot, diffusion-weighted, spin-echo echo planar imaging. The tetrahedral diffusion gradient configuration and four iterations of a set of b-values (one time of 0 mm2/s, and four times of 1000 mm2/s) were used to create isotropic ADC maps with high signal-to-noise ratio. ADC values of gray and white matter were compared among patients and 4 reference subjects. Results: one patient was diagnosed as clinically brain dead after the MR examination. The patient's ADC values of gray and white matter were significantly lower than those of 3 other brain-injured patients. In addition the ADC value of white matter was significantly lower than that of gray matter. Conclusion: The patient with fatal outcome shortly after MR examination differed significantly from other patients with severe brain injury but non-fatal outcome, with regard to ADC values in gray and white matter. This might indicate a prognostic value of ADC maps in the evaluation of traumatic brain injury

  12. Different techniques for investigation of plasma diffusion coefficient in IR-T1 Tokamak

    Science.gov (United States)

    Ghoranneviss, Mahmood; Meshkani, Sakineh; Lafouti, Mansoureh

    2017-03-01

    Diffusion due to the run-away electrons in Tokamak can cause serious damages to the Tokamak walls. In this study, aiming for improving the plasma confinement, the diffusion coefficient was calculated in two different approaches using two different probes. In the first approach; Langmuir probe, was utilized to measure the poloidal electric field, radial flux and consequently the diffusion coefficient. On a more approach, the diffusion coefficient has been estimated by using the ball-pen probe and the Fourier-transform and the assumption of entirely diffusive plasma penetration inside the boron nitride shielding. In order to improve the plasma confinement, external biased voltages of ± 200 V were applied when the plasma experienced its stable phase. Comparing the results, a clear unity can be seen from both the Langmuir approach and the Ball-pen approach. As the results indicate, the diffusion coefficient in Langmuir approach decreased up to 40% when the positive biased voltage of 200 V was applied. However, when the negative biased voltage of 200 V was applied, the diffusion coefficient increased significantly (up to 60%). Ball-pen approach results signify the same results from Langmuir probe. Where, by applying the positive biased voltage of 200 V the diffusion coefficient decreased by almost 40% and on the contrary, the negative biased voltage of 200 V increased the diffusion coefficient up to 30% in general. It can be said that the positive biased voltage contributed to improve the plasma confinement in Tokamak.

  13. Investigation of Interdiffusion Behavior in the Mo-Zr Binary System via Diffusion Couple Studies

    Energy Technology Data Exchange (ETDEWEB)

    A. Paz y Puente; J. Dickson; D.D. Keiser, Jr.; Y.H. Sohn

    2014-03-01

    Zirconium has recently garnered attention for use as a diffusion barrier between U–Mo metallic nuclear fuels and Al alloy cladding. In order to gain a fundamental understanding of the diffusional interactions, the interdiffusion behavior in the binary Mo–Zr system was investigated via solid-to-solid diffusion couples annealed in the temperature range of 750 to 1050 degrees C. A combination of scanning electron microscopy, X-ray energy dispersive spectroscopy, and electron probe microanalysis were used to examine the microstructure and concentration profiles across the interdiffusion zone. A large __-Zr (cI2) solid solution layer and a thin (approximately 1–2 um) layer of Mo2Zr (cF24) developed in all couples. Parabolic growth constants and concentration dependent interdiffusion coefficients were calculated for the Mo2Zr and Zr solid solution phases, respectively. The pre-exponential factor and activation energy for growth of the Mo2Zr phase were determined to be approximately 6.5 × 10- 15 m2/s and 90 kJ/mol, respectively. The interdiffusion coefficient in ___-Zr solid solution decreased with an increase in Mo concentration. Both the pre-exponential factors (2 × 10- 8 m2/s at 2 at.% Mo to near 5 × 10- 8 m2/s at 9 at.% Mo) and activation energies (140 kJ/mol at 2 at.% Mo to approximately 155 kJ/mol at 9 at.% Mo) of interdiffusion coefficients were determined to increase with an increase in Mo concentration.

  14. Measurement of effective Knudsen diffusion coefficients for powder beds used in heterogeneous uptake experiments.

    Science.gov (United States)

    Boulter, James E; Marschall, Jochen

    2006-09-07

    The effective Knudsen diffusion coefficients for characteristic oxide powder beds used in heterogeneous uptake experiments have been measured using countercurrent diffusion and transient pressure drop techniques. Room-temperature thermal-velocity-normalized effective Knudsen diffusion coefficients are found to lie in the 0.15 to 0.35 microm range for magnesium silicate, aluminum oxide, and iron oxide powder beds. Measured values are compared with theoretical estimates and are consistent with low bed tortuosities (below 3) expected for media with open porosity above 0.5. The impact of uncertainties in effective diffusion coefficients on corrections of measured uptake coefficients is discussed. The value of careful uptake measurements in both the low and high sample mass limits is reinforced, as this allows uptake corrections independent of explicitly measured or estimated diffusion coefficient values. It is suggested that correction procedures requiring tortuosity values greater than 3 are suspect.

  15. The collective diffusion coefficient as a shape detector of the surface energy landscape

    Science.gov (United States)

    Mińkowski, Marcin; Załuska–Kotur, Magdalena A.

    2018-01-01

    The general expression for the diffusion coefficient for a dense, interacting particle system moving through a one-dimensional non-homogeneous energy potential is derived. Based on this expression, it is shown that the diffusion coefficient as a function of density depends to a great extent on the shape of the energy landscape. The presence of other particles affects the diffusion coefficient in another way as they pass through the same energy barriers, but set in a different order. The obtained result comes from a variational approach to diffusion and the interactions are taken into account using the transfer-matrix method. Interactions impact on the dynamics of the system, both by changing the equilibrium probabilities of the occupied states and by changing the barriers for the particle jumps. Several examples of diffusion in different energy potentials are presented and the dependence of the diffusion coefficient on potential and interactions is discussed.

  16. Determination of trapping parameters and the chemical diffusion coefficient from hydrogen permeation experiments

    International Nuclear Information System (INIS)

    Svoboda, J.; Mori, G.; Prethaler, A.; Fischer, F.D.

    2014-01-01

    Highlights: • A modeling study for diffusion of hydrogen with traps is presented. • Introduction of a new chemical diffusion coefficient. • Density of traps and average depth of traps can be determined. • Lattice diffusion and sub-surface concentration of atomic hydrogen can be determined. - Abstract: An improved diffusion theory accounting for trapping effects is applied to evaluation of hydrogen permeation experiments performed for pure iron and pearlitic and martensitic steels. The trapping parameters as molar volume and depth of traps are determined by fitting experiments by simulations based on the theory. The concentration-dependent chemical diffusion coefficient of hydrogen is extracted indicating that the trapping effect on diffusion in pure iron and pearlitic steel is negligible. However, it is significant for martensitic steel, for which the chemical diffusion coefficient cannot be considered as concentration-independent as it is established in current standards

  17. Effective diffusion coefficients of DNAPL waste components in saturated low permeability soil materials

    Science.gov (United States)

    Ayral-Cinar, Derya; Demond, Avery H.

    2017-12-01

    Diffusion is regarded as the dominant transport mechanism into and out of low permeable subsurface lenses and layers in the subsurface. But, some reports of mass storage in such zones are higher than what might be attributable to diffusion, based on estimated diffusion coefficients. Despite the importance of diffusion to efforts to estimate the quantity of residual contamination in the subsurface, relatively few studies present measured diffusion coefficients of organic solutes in saturated low permeability soils. This study reports the diffusion coefficients of a trichloroethylene (TCE), and an anionic surfactant, Aerosol OT (AOT), in water-saturated silt and a silt-montmorillonite (25:75) mixture, obtained using steady-state experiments. The relative diffusivity ranged from 0.11 to 0.17 for all three compounds for the silt and the silt-clay mixture that was allowed to expand. In the case in which the swelling was constrained, the relative diffusivity was about 0.07. In addition, the relative diffusivity of 13C-labeled TCE through a water saturated silt-clay mixture that had contacted a field dense non-aqueous phase liquid (DNAPL) for 18 months was measured and equaled 0.001. These experimental results were compared with the estimates generated using common correlations, and it was found that, in all cases, the measured diffusion coefficients were significantly lower than the estimated. Thus, the discrepancy between mass accumulations observed in the field and the mass storage that can attributable to diffusion may be greater than previously believed.

  18. Modeling and experiments for the time-dependent diffusion coefficient during methane desorption from coal

    Science.gov (United States)

    Cheng-Wu, Li; Hong-Lai, Xue; Cheng, Guan; Wen-biao, Liu

    2018-04-01

    Statistical analysis shows that in the coal matrix, the diffusion coefficient for methane is time-varying, and its integral satisfies the formula μt κ /(1 + β κ ). Therefore, a so-called dynamic diffusion coefficient model (DDC model) is developed. To verify the suitability and accuracy of the DDC model, a series of gas diffusion experiments were conducted using coal particles of different sizes. The results show that the experimental data can be accurately described by the DDC and bidisperse models, but the fit to the DDC model is slightly better. For all coal samples, as time increases, the effective diffusion coefficient first shows a sudden drop, followed by a gradual decrease before stabilizing at longer times. The effective diffusion coefficient has a negative relationship with the size of the coal particle. Finally, the relationship between the constants of the DDC model and the effective diffusion coefficient is discussed. The constant α (μ/R 2 ) denotes the effective coefficient at the initial time, and the constants κ and β control the attenuation characteristic of the effective diffusion coefficient.

  19. ORIGINAL ARTICLE Value of apparent diffusion coefficient (ADC) in ...

    African Journals Online (AJOL)

    of DWI-MRI in the treatment of brain tumours and found that malignant tumours, owing to their high cellularity, have a restriction of water movement (diffusion) reflected by a low ADC value; and, when the tumours respond to treatment, the ADC value will increase. (less restriction of water movement) because of a decrease in ...

  20. Scale Dependence of the Effective Matrix Diffusion Coefficient : Evidence and Preliminary Interpretation

    International Nuclear Information System (INIS)

    H.H. Liu; Y. Zhang

    2006-01-01

    The exchange of solute mass (through molecular diffusion) between fluid in fractures and fluid in the rock matrix is called matrix diffusion. Owing to the orders-of-magnitude slower flow velocity in the matrix compared to fractures, matrix diffusion can significantly retard solute transport in fractured rock, and therefore is an important process for a variety of problems, including remediation of subsurface contamination and geological disposal of nuclear waste. The effective matrix diffusion coefficient (molecular diffusion coefficient in free water multiplied by matrix tortuosity) is an important parameter for describing matrix diffusion, and in many cases largely determines overall solute transport behavior. While matrix diffusion coefficient values measured from small rock samples in the laboratory are generally used for modeling field-scale solute transport in fractured rock (Boving and Grathwohl, 2001), several research groups recently have independently found that effective matrix diffusion coefficients much larger than laboratory measurements are needed to match field-scale tracer-test data (Neretnieks, 2002; Becker and Shapiro, 2000; Shapiro, 2001; Liu et al., 2003,2004a). In addition to the observed enhancement, Liu et al. (2004b), based on a relatively small number of field-test results, reported that the effective matrix diffusion coefficient might be scale dependent, and, like permeability and dispersivity, it seems to increases with test scale. This scale-dependence has important implications for large-scale solute transport in fractured rock. Although a number of mechanisms have been proposed to explain the enhancement of the effective matrix diffusion coefficient, the potential scale dependence and its mechanisms are not fully investigated at this stage. The major objective of this study is to again demonstrate (based on more data published in the literature than those used in Liu et al. [2004b]) the potential scale dependence of the effective

  1. Self-diffusion coefficients of the metastable Lennard-Jones vapor

    Energy Technology Data Exchange (ETDEWEB)

    Nie Chu; Zhou Youhua [School of Physics and Information Engineering, Jianghan University, Wuhan 430056 (China); Marlow, W H; Hassan, Y A [Department of Nuclear Engineering, Texas A and M University, College Station, TX 77843 (United States)], E-mail: yhzhou@jhun.edu.cn

    2008-10-15

    Self-diffusion coefficients of a metastable Lennard-Jones vapor were obtained using the memory function formalism and the frequency moments of the velocity autocorrelation function at reduced temperatures from 0.75 to 1.0. The radial density distribution functions used to evaluate the second, fourth and sixth frequency moments of the velocity autocorrelation function were obtained from the restricted canonical ensemble Monte Carlo simulation (Corti and Debenedetti 1994 Chem. Eng. Sci. 49 2717). The self-diffusion coefficients at reduced temperature 0.75 do not vary monotonically as the density increases, and for the other three temperatures the self-diffusion coefficients vary normally.

  2. Investigation of a phantom for diffusion weighted imaging that controlled the apparent diffusion coefficient using gelatin and sucrose

    International Nuclear Information System (INIS)

    Tamura, Takayuki; Usui, Shuji; Akiyama, Mitoshi

    2009-01-01

    When studying diffusion weighted imaging (DWI), it is important to create a phantom that has a reliably controlled diffusion coefficient. In this study, we investigated phantoms to control both the diffusion coefficient and the T2-value by changing the concentration of gelatin or sucrose and MnCl 2 , respectively. The results showed that the diffusion coefficient decreased linearly with increases in the gelatin or sucrose concentration, and decreasing of their relaxation times was observed. By properly adjusting the MnCl 2 concentrations, we were able to equalize the T2-values between phantoms having different gelatin or sucrose concentrations. Temperature dependence of the diffusion coefficient was also revealed. This phantom can be made stable for a few months by adding a small amount of NaN 3 as an antiseptic agent, has a diffusion coefficient similar to that of neural tissue or clinical tumor, and is able to control the T2-value properly. We consider this phantom suitable for studying SE-type DWI and contributes to elucidation of this technique. (author)

  3. Two-dimensional simulation of reactive diffusion in binary systems

    Czech Academy of Sciences Publication Activity Database

    Svoboda, Jiří; Stopka, J.; Fischer, F. D.

    2014-01-01

    Roč. 95, DEC (2014), s. 309-315 ISSN 0927-0256 R&D Projects: GA ČR(CZ) GA14-24252S Institutional support: RVO:68081723 Keywords : Phase transformation * Diffusion-controlled interface migration * Reactive diffusion * Multiphase system * Intermetallic compounds Subject RIV: BJ - Thermodynamics Impact factor: 2.131, year: 2014

  4. Apparent diffusion coefficient of diffusion weighted MRI in endometrial carcinoma—Relationship with local invasiveness

    International Nuclear Information System (INIS)

    Cao, Kun; Gao, Min; Sun, Ying-Shi; Li, Yan-Ling; Sun, Yu; Gao, Yu-Nong; Zhang, Xiao-Peng

    2012-01-01

    Objective: To evaluate the relationship between apparent diffusion coefficient (ADC) value and the local invasiveness of endometrial carcinoma. Methods and materials: The MR imaging of seventy-three patients with endometrial carcinoma proved by post-operative pathology and sixty-four patients with healthy uteri were retrospectively reviewed. All MR examinations included axial T2WI and T1WI, sagittal T2WI and diffusion-weighted sequences (b = 0 and b = 1000 s/mm 2 ). Tumor size, mean ADC value (ADCm) and quartile ADC (ADCq) were acquired on post-processing workstation using voxel-analysis software. Differences between the ADC values among three layers of normal uterine body and endometrial carcinomas were compared by ANOVA test. Groups were divided according to pathologic type, histologic grade, depth of myometrial infiltration, presence of cervical invasion and lymphovascular space invasion, and lymph node metastasis. Tumor size and ADC values were compared and analyzed. Results: ADC values were different in three zones of uterine body (P −3 mm 2 /s] and highest in outer myometrium [(1.496 ± 0.196) × 10 −3 mm 2 /s]. Mean ADC value of endometrial carcinomas [(1.011 ± 0.121) × 10 −3 mm 2 /s] was lower than the normal uterine body. Quartile ADC and tumor size were greater in groups with more invasive pathologic factors (P < 0.05). Deep myometrial infiltration, cervical invasion, lymphovascular space invasion and lymph node metastasis were more common as quartile ADC values and tumor sizes increased. Conclusion: Mean ADC value was lower in endometrial carcinoma was lower than the normal uterus. Quartile ADC, representing the intra-tumor heterogeneity of water movement, had a profound relationship with invasiveness of endometrial carcinomas, while mean ADC value did not. ADC values may serve as a quantitative indicator to complement routine sequences.

  5. Extracting surface diffusion coefficients from batch adsorption measurement data: application of the classic Langmuir kinetics model.

    Science.gov (United States)

    Chu, Khim Hoong

    2017-11-09

    Surface diffusion coefficients may be estimated by fitting solutions of a diffusion model to batch kinetic data. For non-linear systems, a numerical solution of the diffusion model's governing equations is generally required. We report here the application of the classic Langmuir kinetics model to extract surface diffusion coefficients from batch kinetic data. The use of the Langmuir kinetics model in lieu of the conventional surface diffusion model allows derivation of an analytical expression. The parameter estimation procedure requires determining the Langmuir rate coefficient from which the pertinent surface diffusion coefficient is calculated. Surface diffusion coefficients within the 10 -9 to 10 -6  cm 2 /s range obtained by fitting the Langmuir kinetics model to experimental kinetic data taken from the literature are found to be consistent with the corresponding values obtained from the traditional surface diffusion model. The virtue of this simplified parameter estimation method is that it reduces the computational complexity as the analytical expression involves only an algebraic equation in closed form which is easily evaluated by spreadsheet computation.

  6. Estimation of the effective intercellular diffusion coefficient in cell monolayers coupled by gap junctions.

    Science.gov (United States)

    Olesen, Niels Erik; Hofgaard, Johannes P; Holstein-Rathlou, Niels-Henrik; Nielsen, Morten Schak; Jacobsen, Jens Christian Brings

    2012-07-16

    A recently developed dye-based assay to study gap junction permeability is analysed. The assay is based on electroporation of dye into a large number of connexin 43 expressing cells, grown to confluency on electrically conductive slides. The subsequent intercellular spread of dye to non-electroporated parts of the monolayer enables estimation of the intercellular coupling. So far, the extent of dye spread has been analyzed in qualitative terms only and not in a manner based directly on the physics of the underlying diffusion process. We apply a continuum approximation assuming that the observed dye spread can be described by Fick's law of diffusion. Deduced from Fick's law, new measures are presented which directly relate the observed spread of dye to the diffusion coefficient. The theoretical framework enables the estimation of an effective diffusion coefficient from Fick's law independently of the specific indicator substance used in the assay. For Lucifer Yellow, diffusion stops within few minutes after the electroporation. Therefore only an order-of-magnitude estimate of the diffusion coefficient can be given for this dye. In terms of the underlying diffusion coefficient, the hitherto used measures give a relatively poor degree of quantification. In contrast, the present methods may yield direct information on the effective intercellular diffusion coefficient and hence provide additional and more precise information as to the permeability modulating effect of various substances. Copyright © 2011 Elsevier B.V. All rights reserved.

  7. Comparison of experimental methods for estimating matrix diffusion coefficients for contaminant transport modeling

    Science.gov (United States)

    Telfeyan, Katherine; Ware, S. Doug; Reimus, Paul W.; Birdsell, Kay H.

    2018-02-01

    Diffusion cell and diffusion wafer experiments were conducted to compare methods for estimating effective matrix diffusion coefficients in rock core samples from Pahute Mesa at the Nevada Nuclear Security Site (NNSS). A diffusion wafer method, in which a solute diffuses out of a rock matrix that is pre-saturated with water containing the solute, is presented as a simpler alternative to the traditional through-diffusion (diffusion cell) method. Both methods yielded estimates of effective matrix diffusion coefficients that were within the range of values previously reported for NNSS volcanic rocks. The difference between the estimates of the two methods ranged from 14 to 30%, and there was no systematic high or low bias of one method relative to the other. From a transport modeling perspective, these differences are relatively minor when one considers that other variables (e.g., fracture apertures, fracture spacings) influence matrix diffusion to a greater degree and tend to have greater uncertainty than effective matrix diffusion coefficients. For the same relative random errors in concentration measurements, the diffusion cell method yields effective matrix diffusion coefficient estimates that have less uncertainty than the wafer method. However, the wafer method is easier and less costly to implement and yields estimates more quickly, thus allowing a greater number of samples to be analyzed for the same cost and time. Given the relatively good agreement between the methods, and the lack of any apparent bias between the methods, the diffusion wafer method appears to offer advantages over the diffusion cell method if better statistical representation of a given set of rock samples is desired.

  8. Comparison of experimental methods for estimating matrix diffusion coefficients for contaminant transport modeling.

    Science.gov (United States)

    Telfeyan, Katherine; Ware, S Doug; Reimus, Paul W; Birdsell, Kay H

    2018-02-01

    Diffusion cell and diffusion wafer experiments were conducted to compare methods for estimating effective matrix diffusion coefficients in rock core samples from Pahute Mesa at the Nevada Nuclear Security Site (NNSS). A diffusion wafer method, in which a solute diffuses out of a rock matrix that is pre-saturated with water containing the solute, is presented as a simpler alternative to the traditional through-diffusion (diffusion cell) method. Both methods yielded estimates of effective matrix diffusion coefficients that were within the range of values previously reported for NNSS volcanic rocks. The difference between the estimates of the two methods ranged from 14 to 30%, and there was no systematic high or low bias of one method relative to the other. From a transport modeling perspective, these differences are relatively minor when one considers that other variables (e.g., fracture apertures, fracture spacings) influence matrix diffusion to a greater degree and tend to have greater uncertainty than effective matrix diffusion coefficients. For the same relative random errors in concentration measurements, the diffusion cell method yields effective matrix diffusion coefficient estimates that have less uncertainty than the wafer method. However, the wafer method is easier and less costly to implement and yields estimates more quickly, thus allowing a greater number of samples to be analyzed for the same cost and time. Given the relatively good agreement between the methods, and the lack of any apparent bias between the methods, the diffusion wafer method appears to offer advantages over the diffusion cell method if better statistical representation of a given set of rock samples is desired. Copyright © 2018 Elsevier B.V. All rights reserved.

  9. Comparison of Experimental Methods for Estimating Matrix Diffusion Coefficients for Contaminant Transport Modeling

    Energy Technology Data Exchange (ETDEWEB)

    Telfeyan, Katherine Christina [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Ware, Stuart Douglas [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Reimus, Paul William [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Birdsell, Kay Hanson [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-11-06

    Diffusion cell and diffusion wafer experiments were conducted to compare methods for estimating matrix diffusion coefficients in rock core samples from Pahute Mesa at the Nevada Nuclear Security Site (NNSS). A diffusion wafer method, in which a solute diffuses out of a rock matrix that is pre-saturated with water containing the solute, is presented as a simpler alternative to the traditional through-diffusion (diffusion cell) method. Both methods yielded estimates of matrix diffusion coefficients that were within the range of values previously reported for NNSS volcanic rocks. The difference between the estimates of the two methods ranged from 14 to 30%, and there was no systematic high or low bias of one method relative to the other. From a transport modeling perspective, these differences are relatively minor when one considers that other variables (e.g., fracture apertures, fracture spacings) influence matrix diffusion to a greater degree and tend to have greater uncertainty than diffusion coefficients. For the same relative random errors in concentration measurements, the diffusion cell method yields diffusion coefficient estimates that have less uncertainty than the wafer method. However, the wafer method is easier and less costly to implement and yields estimates more quickly, thus allowing a greater number of samples to be analyzed for the same cost and time. Given the relatively good agreement between the methods, and the lack of any apparent bias between the methods, the diffusion wafer method appears to offer advantages over the diffusion cell method if better statistical representation of a given set of rock samples is desired.

  10. Comparison of diffusion coefficients and activation energies for AG diffusion in silicon carbide

    International Nuclear Information System (INIS)

    Kim, Bong Goo; Yeo, Sung Hwan; Lee, Young Woo; Cho, Moon Sung

    2015-01-01

    The migration of silver (Ag) in silicon carbide (SiC) and 110mAg through SiC of irradiated tri-structural isotropic (TRISO) fuel has been studied for the past three to four decades. However, there is no satisfactory explanation for the transport mechanism of Ag in SiC. In this work, the diffusion coefficients of Ag measured and/or estimated in previous studies were reviewed, and then pre-exponential factors and activation energies from the previous experiments were evaluated using Arrhenius equation. The activation energy is 247.4 kJ·mol -1 from Ag paste experiments between two SiC layers produced using fluidized-bed chemical vapor deposition (FBCVD), 125.3 kJ·mol -1 from integral release experiments (annealing of irradiated TRISO fuel), 121.8 kJ·mol -1 from fractional Ag release during irradiation of TRISO fuel in high flux reactor (HFR), and 274.8 kJ·mol -1 from Ag ion implantation experiments, respectively. The activation energy from ion implantation experiments is greater than that from Ag paste, fractional release and integral release, and the activation energy from Ag paste experiments is approximately two times greater than that from integral release experiments and fractional Ag release during the irradiation of TRISO fuel in HFR. The pre-exponential factors are also very different depending on the experimental methods and estimation. From a comparison of the pre-exponential factors and activation energies, it can be analogized that the diffusion mechanism of Ag using ion implantation experiment is different from other experiments, such as a Ag paste experiment, integral release experiments, and heating experiments after irradiating TRISO fuel in HFR. However, the results of this work do not support the long held assumption that Ag release from FBCVD-SiC, used for the coating layer in TRISO fuel, is dominated by grain boundary diffusion. In order to understand in detail the transport mechanism of Ag through the coating layer, FBCVD-SiC in TRISO fuel, a

  11. Imaging cell size and permeability in biological tissue using the diffusion-time dependence of the apparent diffusion coefficient.

    Science.gov (United States)

    Dietrich, Olaf; Hubert, Alexander; Heiland, Sabine

    2014-06-21

    The purpose of this study was to analyze and evaluate a model of restricted water diffusion between equidistant permeable membranes for cell-size and permeability measurements in biological tissue. Based on the known probability distribution of diffusion distances after the diffusion time τ in a system of permeable membranes characterized by three parameters (membrane permeability P, membrane distance L, and free diffusivity D0), an equivalent dimensionless model was derived with a probability distribution characterized by only a single (dimensionless) tissue parameter [Formula: see text]. Evaluating this proposed model function, the dimensionless diffusion coefficient [Formula: see text] was numerically calculated for 60 values of the dimensionless diffusion time [Formula: see text] and 35 values of [Formula: see text]. Diffusion coefficients were measured in a carrot by diffusion-weighted magnetic resonance imaging (MRI) at 18 diffusion times between 9.9 and 1022.7 ms and fitted to the simulation results [Formula: see text] to determine L, P, and D0. The measured diffusivities followed the simulated dependence of [Formula: see text]. Determined cell sizes varied from 21 to 76 μm, permeabilities from 0.007 to 0.039 μm(-1), and the free diffusivities from 1354 to 1713 μm(2) s(-1). In conclusion, the proposed dimensionless tissue model can be used to determine tissue parameters (D0, L, P) based on diffusion MRI with multiple diffusion times. Measurements in a carrot showed a good agreement of the cell diameter, L, determined by diffusion MRI and by light microscopy.

  12. Determination of diffusion coefficients of various livestock antibiotics in water at infinite dilution

    Science.gov (United States)

    Soriano, Allan N.; Adamos, Kristoni G.; Bonifacio, Pauline B.; Adornado, Adonis P.; Bungay, Vergel C.; Vairavan, Rajendaran

    2017-11-01

    The fate of antibiotics entering the environment raised concerns on the possible effect of antimicrobial resistance bacteria. Prediction of the fate and transport of these particles are needed to be determined, significantly the diffusion coefficient of antibiotic in water at infinite dilution. A systematic determination of diffusion coefficient of antibiotic in water at infinite dilution of five different kinds of livestock antibiotics namely: Amtyl, Ciprotyl, Doxylak Forte, Trisullak, and Vetracin Gold in the 293.15 to 313.15 K temperature range are reported through the use of the method involving the electrolytic conductivity measurements. A continuous stirred tank reactor is utilized to measure the electrolytic conductivities of the considered systems. These conductivities are correlated by using the Nernst-Haskell equation to determine the infinite dilution diffusion coefficient. Determined diffusion coefficients are based on the assumption that in dilute solution, these antibiotics behave as strong electrolyte from which H+ cation dissociate from the antibiotic's anion.

  13. Determination of the concentration dependent diffusion coefficient of nitrogen in expanded austenite

    DEFF Research Database (Denmark)

    Christiansen, Thomas; Somers, Marcel A. J.

    2008-01-01

    in the composition range where nitrogen can be extracted by hydrogen gas at the diffusion temperature. Numerical simulation of the denitriding experiments shows that the thus determined concentration dependent diffusion coefficients are an accurate approximation of the actual diffusivity of nitrogen in expanded......The concentration dependent diffusion coefficient of nitrogen in expanded austenite was determined from of the rate of retracting nitrogen from thin initially N-saturated coupons. Nitrogen saturated homogeneous foils of expanded austenite were obtained by nitriding AISI 304 and AISI 316 in pure...... ammonia at 693 K and 718 K. Denitriding experiments were performed by equilibrating the foils with a successively lower nitrogen activity, as imposed by a gas mixture of ammonia and hydrogen. The concentration dependent diffusion coefficient of nitrogen in expanded austenite was approximated...

  14. FITTING OF THE DATA FOR DIFFUSION COEFFICIENTS IN UNSATURATED POROUS MEDIA

    International Nuclear Information System (INIS)

    B. Bullard

    1999-01-01

    The purpose of this calculation is to evaluate diffusion coefficients in unsaturated porous media for use in the TSPA-VA analyses. Using experimental data, regression techniques were used to curve fit the diffusion coefficient in unsaturated porous media as a function of volumetric water content. This calculation substantiates the model fit used in Total System Performance Assessment-1995 An Evaluation of the Potential Yucca Mountain Repository (TSPA-1995), Section 6.5.4

  15. FITTING OF THE DATA FOR DIFFUSION COEFFICIENTS IN UNSATURATED POROUS MEDIA

    Energy Technology Data Exchange (ETDEWEB)

    B. Bullard

    1999-05-01

    The purpose of this calculation is to evaluate diffusion coefficients in unsaturated porous media for use in the TSPA-VA analyses. Using experimental data, regression techniques were used to curve fit the diffusion coefficient in unsaturated porous media as a function of volumetric water content. This calculation substantiates the model fit used in Total System Performance Assessment-1995 An Evaluation of the Potential Yucca Mountain Repository (TSPA-1995), Section 6.5.4.

  16. FIELD-SCALE EFFECTIVE MATRIX DIFFUSION COEFFICIENT FOR FRACTURED ROCK: RESULTS FROM LITERATURE SURVEY

    International Nuclear Information System (INIS)

    Zhou, Q.; Hui-Hai Liu; Molz, F.J.; Zhang, Y.; Bodvarsson, G.S.

    2005-01-01

    Matrix diffusion is an important mechanism for solute transport in fractured rock. We recently conducted a literature survey on the effective matrix diffusion coefficient, D m e , a key parameter for describing matrix diffusion processes at the field scale. Forty field tracer tests at 15 fractured geologic sites were surveyed and selected for the study, based on data availability and quality. Field-scale D m e values were calculated, either directly using data reported in the literature or by reanalyzing the corresponding field tracer tests. Surveyed data indicate that the effective-matrix-diffusion-coefficient factor F D (defined as the ratio of D m e to the lab-scale matrix diffusion coefficient [D m ] of the same tracer) is generally larger than one, indicating that the effective matrix diffusion coefficient in the field is comparatively larger than the matrix diffusion coefficient at the rock-core scale. This larger value can be attributed to the many mass-transfer processes at different scales in naturally heterogeneous, fractured rock systems. Furthermore, we observed a moderate trend toward systematic increase in the F D value with observation scale, indicating that the effective matrix diffusion coefficient is likely to be statistically scale dependent. The F D value ranges from 1 to 10,000 for observation scales from 5 to 2,000 m. At a given scale, the F D value varies by two orders of magnitude, reflecting the influence of differing degrees of fractured rock heterogeneity at different sites. In addition, the surveyed data indicate that field-scale longitudinal dispersivity generally increases with observation scale, which is consistent with previous studies. The scale-dependent field-scale matrix diffusion coefficient (and dispersivity) may have significant implications for assessing long-term, large-scale radionuclide and contaminant transport events in fractured rock, both for nuclear waste disposal and contaminant remediation

  17. The Gini coefficient: a methodological pilot study to assess fetal brain development employing postmortem diffusion MRI

    Energy Technology Data Exchange (ETDEWEB)

    Viehweger, Adrian; Sorge, Ina; Hirsch, Wolfgang [University Hospital Leipzig, Department of Pediatric Radiology, Leipzig (Germany); Riffert, Till; Dhital, Bibek; Knoesche, Thomas R.; Anwander, Alfred [Max Planck Institute for Human Cognitive and Brain Sciences, Leipzig (Germany); Stepan, Holger [University Leipzig, Department of Obstetrics, Leipzig (Germany)

    2014-10-15

    Diffusion-weighted imaging (DWI) is important in the assessment of fetal brain development. However, it is clinically challenging and time-consuming to prepare neuromorphological examinations to assess real brain age and to detect abnormalities. To demonstrate that the Gini coefficient can be a simple, intuitive parameter for modelling fetal brain development. Postmortem fetal specimens(n = 28) were evaluated by diffusion-weighted imaging (DWI) on a 3-T MRI scanner using 60 directions, 0.7-mm isotropic voxels and b-values of 0, 150, 1,600 s/mm{sup 2}. Constrained spherical deconvolution (CSD) was used as the local diffusion model. Fractional anisotropy (FA), apparent diffusion coefficient (ADC) and complexity (CX) maps were generated. CX was defined as a novel diffusion metric. On the basis of those three parameters, the Gini coefficient was calculated. Study of fetal brain development in postmortem specimens was feasible using DWI. The Gini coefficient could be calculated for the combination of the three diffusion parameters. This multidimensional Gini coefficient correlated well with age (Adjusted R{sup 2} = 0.59) between the ages of 17 and 26 gestational weeks. We propose a new method that uses an economics concept, the Gini coefficient, to describe the whole brain with one simple and intuitive measure, which can be used to assess the brain's developmental state. (orig.)

  18. The Gini coefficient: a methodological pilot study to assess fetal brain development employing postmortem diffusion MRI

    International Nuclear Information System (INIS)

    Viehweger, Adrian; Sorge, Ina; Hirsch, Wolfgang; Riffert, Till; Dhital, Bibek; Knoesche, Thomas R.; Anwander, Alfred; Stepan, Holger

    2014-01-01

    Diffusion-weighted imaging (DWI) is important in the assessment of fetal brain development. However, it is clinically challenging and time-consuming to prepare neuromorphological examinations to assess real brain age and to detect abnormalities. To demonstrate that the Gini coefficient can be a simple, intuitive parameter for modelling fetal brain development. Postmortem fetal specimens(n = 28) were evaluated by diffusion-weighted imaging (DWI) on a 3-T MRI scanner using 60 directions, 0.7-mm isotropic voxels and b-values of 0, 150, 1,600 s/mm 2 . Constrained spherical deconvolution (CSD) was used as the local diffusion model. Fractional anisotropy (FA), apparent diffusion coefficient (ADC) and complexity (CX) maps were generated. CX was defined as a novel diffusion metric. On the basis of those three parameters, the Gini coefficient was calculated. Study of fetal brain development in postmortem specimens was feasible using DWI. The Gini coefficient could be calculated for the combination of the three diffusion parameters. This multidimensional Gini coefficient correlated well with age (Adjusted R 2 = 0.59) between the ages of 17 and 26 gestational weeks. We propose a new method that uses an economics concept, the Gini coefficient, to describe the whole brain with one simple and intuitive measure, which can be used to assess the brain's developmental state. (orig.)

  19. Optimal Parameters to Determine the Apparent Diffusion Coefficient in Diffusion Weighted Imaging via Simulation

    Science.gov (United States)

    Perera, Dimuthu

    Diffusion weighted (DW) Imaging is a non-invasive MR technique that provides information about the tissue microstructure using the diffusion of water molecules. The diffusion is generally characterized by the apparent diffusion coefficient (ADC) parametric map. The purpose of this study is to investigate in silico how the calculation of ADC is affected by image SNR, b-values, and the true tissue ADC. Also, to provide optimal parameter combination depending on the percentage accuracy and precision for prostate peripheral region cancer application. Moreover, to suggest parameter choices for any type of tissue, while providing the expected accuracy and precision. In this research DW images were generated assuming a mono-exponential signal model at two different b-values and for known true ADC values. Rician noise of different levels was added to the DWI images to adjust the image SNR. Using the two DWI images, ADC was calculated using a mono-exponential model for each set of b-values, SNR, and true ADC. 40,000 ADC data were collected for each parameter setting to determine the mean and the standard-deviation of the calculated ADC, as well as the percentage accuracy and precision with respect to the true ADC. The accuracy was calculated using the difference between known and calculated ADC. The precision was calculated using the standard-deviation of calculated ADC. The optimal parameters for a specific study was determined when both the percentage accuracy and precision were minimized. In our study, we simulated two true ADCs (ADC 0.00102 for tumor and 0.00180 mm2/s for normal prostate peripheral region tissue). Image SNR was varied from 2 to 100 and b-values were varied from 0 to 2000s/mm2. The results show that the percentage accuracy and percentage precision were minimized with image SNR. To increase SNR, 10 signal-averagings (NEX) were used considering the limitation in total scan time. The optimal NEX combination for tumor and normal tissue for prostate

  20. Experimental Determination of Drug Diffusion Coefficients in Unstirred Aqueous Environments by Temporally Resolved Concentration Measurements.

    Science.gov (United States)

    di Cagno, Massimiliano Pio; Clarelli, Fabrizio; Våbenø, Jon; Lesley, Christina; Rahman, Sokar Darsim; Cauzzo, Jennifer; Franceschinis, Erica; Realdon, Nicola; Stein, Paul C

    2018-04-02

    The diffusion coefficient (also known as diffusivity) of an active pharmaceutical ingredient (API) is a fundamental physicochemical parameter that affects passive diffusion through biological barriers and, as a consequence, bioavailability and biodistribution. However, this parameter is often neglected, and it is quite difficult to find diffusion coefficients of small molecules of pharmaceutical relevance in the literature. The available methods to measure diffusion coefficients of drugs all suffer from limitations that range from poor sensitivity to high selectivity of the measurements or the need for dedicated instrumentation. In this work, a simple but reliable method based on time-resolved concentration measurements by UV-visible spectroscopy in an unstirred aqueous environment was developed. This method is based on spectroscopic measurement of the variation of the local concentration of a substance during spontaneous migration of molecules, followed by standard mathematical treatment of the data in order to solve Fick's law of diffusion. This method is extremely sensitive and results in highly reproducible data. The technique was also employed to verify the influence of the environmental characteristics (i.e., ionic strength and presence of complexing agents) on the diffusivity. The method can be employed in any research laboratory equipped with a standard UV-visible spectrophotometer and could become a useful and straightforward tool in order to characterize diffusion coefficients in physiological conditions and help to better understand the drug permeability process.

  1. The apparent diffusion coefficient of water in gray and white matter of the infant brain

    DEFF Research Database (Denmark)

    Toft, P B; Leth, H; Peitersen, Birgit

    1996-01-01

    PURPOSE: The purpose was to obtain normal values of the apparent diffusion coefficient (ADC) in the infant brain and to compare ADC maps with T1- and T2-weighted images. METHOD: Diffusion was measured in nine infants with an ECG-gated SE sequence compensated for first-order motion. One axial slic...

  2. Electrochemical measurements of diffusion coefficients and activity coefficients for MnCl2 in molten eutectic LiCl-KCl

    Science.gov (United States)

    Horvath, D.; Rappleye, D.; Bagri, P.; Simpson, M. F.

    2017-09-01

    An electrochemical study of manganese chloride in molten salt mixtures of eutectic LiCl-KCl was carried out using a variety of electrochemical methods in a high temperature cell including cyclic voltammetry (CV), chronopotentiometry (CP), chronoamperometry (CA), and open circuit potentiometry. Single step reduction from Mn2+ to Mn(0) was observed on both W and Mo working electrodes. Using a combination of these methods, measurements were made of activity coefficient and diffusion coefficient for MnCl2 in LiCl-KCl as a function of concentration (3.54 × 10-4 to 3.60 × 10-3 mol fraction of MnCl2) at 773K. From OCP measurements, values for activity coefficient varied from 0.014 to 0.0071. Diffusion coefficients varied with concentration and differed based on measurement method (CV, CA, or CP). Based on cyclic Mn(II) ranged from 1.1 to 2.8 × 10-5 cm2/s depending on concentration.

  3. Diffusion weighted imaging and estimation of prognosis using apparent diffusion coefficient measurements in ischemic stroke

    Energy Technology Data Exchange (ETDEWEB)

    Gonen, Korcan Aysun, E-mail: aysunbalc@yahoo.com [Department of Radiology, State Hospital, Eski Cami district, Hastane street, N:1, 59300, Tekirdag (Turkey); Simsek, Mehmet Masum, E-mail: radyoloji@haydapasanumune.gov.tr [Department of Radiology, Haydarpasa Numune Training and Research Hospital, Tibbiye street, Uskudar 34200, Istanbul (Turkey)

    2010-11-15

    Objective: Estimation of the prognosis of infarction by using diffusion weighted imaging (DWI) and quantitative apparent diffusion coefficient (ADC) measurements. Methods: 23 patients having acute stroke symptoms with verified infarction in magnetic resonance imaging (MRI) were included in this study. Their MRI studies were performed between 6 and 12 h after the onset of their symptoms and were repeated on the fifth day. The infarction volumes were calculated by using DWI and the patients were divided into two groups as the ones having an expansion in the infarction area (group 1, n = 16) and the others having no expansion in the infarction area (group 2, n = 7). Quantitative ADC values were estimated. The groups were compared in terms of the ADC values on ADC maps obtained from DWI, performed during the between 6 and 12 h from the onset of the symptoms, referring to the core of the infarction (ADC{sub IC}), ischemic penumbra (ADC{sub P}) and the nonischemic parenchymal tissue (ADC{sub N}). P values < 0.05 were accepted to be statistically significant. Results: During the between 6 and 12 h mean infarction volume calculated by DWI was 23.3 cm{sup 3} for group 1 patients (ranging from 1.1 to 68.6) and this was found to be 40.3 cm{sup 3} (ranging from 1.8 to 91.5) on the fifth day. For the group 2 patients these values were found to be 42.1 cm{sup 3} (ranging from 1 to 94.7) and 41.9 (ranging from 1 to 94.7) for the same intervals respectively. A significant statistical result was failed to be demonstrated between the mean ADC{sub IC} and ADC{sub N} values (p = 0.350 and p = 0.229 respectively). However the comparison of the ADC{sub P} values between the groups was found to be highly significant (p < 0.001). When the differences between the ADC{sub P} and ADC{sub IC} and ADC{sub N} and ADC{sub P} were compared the results proved to be statistically significant (p = 0.038 and p < 0.001 respectively). Conclusions: We believe that ADC results that would be obtained from

  4. Diffusion weighted imaging and estimation of prognosis using apparent diffusion coefficient measurements in ischemic stroke

    International Nuclear Information System (INIS)

    Gonen, Korcan Aysun; Simsek, Mehmet Masum

    2010-01-01

    Objective: Estimation of the prognosis of infarction by using diffusion weighted imaging (DWI) and quantitative apparent diffusion coefficient (ADC) measurements. Methods: 23 patients having acute stroke symptoms with verified infarction in magnetic resonance imaging (MRI) were included in this study. Their MRI studies were performed between 6 and 12 h after the onset of their symptoms and were repeated on the fifth day. The infarction volumes were calculated by using DWI and the patients were divided into two groups as the ones having an expansion in the infarction area (group 1, n = 16) and the others having no expansion in the infarction area (group 2, n = 7). Quantitative ADC values were estimated. The groups were compared in terms of the ADC values on ADC maps obtained from DWI, performed during the between 6 and 12 h from the onset of the symptoms, referring to the core of the infarction (ADC IC ), ischemic penumbra (ADC P ) and the nonischemic parenchymal tissue (ADC N ). P values 3 for group 1 patients (ranging from 1.1 to 68.6) and this was found to be 40.3 cm 3 (ranging from 1.8 to 91.5) on the fifth day. For the group 2 patients these values were found to be 42.1 cm 3 (ranging from 1 to 94.7) and 41.9 (ranging from 1 to 94.7) for the same intervals respectively. A significant statistical result was failed to be demonstrated between the mean ADC IC and ADC N values (p = 0.350 and p = 0.229 respectively). However the comparison of the ADC P values between the groups was found to be highly significant (p P and ADC IC and ADC N and ADC P were compared the results proved to be statistically significant (p = 0.038 and p < 0.001 respectively). Conclusions: We believe that ADC results that would be obtained from the core and the penumbra of the infarction area will be beneficial in the estimation of the infarction prognosis and in the planning of a treatment protocol.

  5. Apparent diffusion coefficient of diffusion weighted MRI in endometrial carcinoma-Relationship with local invasiveness

    Energy Technology Data Exchange (ETDEWEB)

    Cao, Kun, E-mail: kun-cao@hotmail.com [Department of Radiology, Key Laboratory of Carcinogenesis and Translational Research (Ministry of Education), Peking University Cancer Hospital and Institute, 52 Fucheng Road, Haidian District, Beijing 100142 (China); Gao, Min, E-mail: gaominmin202@163.com [Department of Gynecology, Key Laboratory of Carcinogenesis and Translational Research (Ministry of Education), Peking University Cancer Hospital and Institute, 52 Fucheng Road, Haidian District, Beijing 100142 (China); Sun, Ying-Shi, E-mail: sunysabc@163.com [Department of Radiology, Key Laboratory of Carcinogenesis and Translational Research (Ministry of Education), Peking University Cancer Hospital and Institute, 52 Fucheng Road, Haidian District, Beijing 100142 (China); Li, Yan-Ling, E-mail: yanlingli1982@gmail.com [Department of Radiology, Key Laboratory of Carcinogenesis and Translational Research (Ministry of Education), Peking University Cancer Hospital and Institute, 52 Fucheng Road, Haidian District, Beijing 100142 (China); Sun, Yu, E-mail: sunyu_bch@163.com [Department of Pathology, Key Laboratory of Carcinogenesis and Translational Research (Ministry of Education), Peking University Cancer Hospital and Institute, 52 Fucheng Road, Haidian District, Beijing 100142 (China); Gao, Yu-Nong, E-mail: gaoyunong@vip.sina.com [Department of Gynecology, Key Laboratory of Carcinogenesis and Translational Research (Ministry of Education), Peking University Cancer Hospital and Institute, 52 Fucheng Road, Haidian District, Beijing 100142 (China); Zhang, Xiao-Peng, E-mail: zxp@bjcancer.org [Department of Radiology, Key Laboratory of Carcinogenesis and Translational Research (Ministry of Education), Peking University Cancer Hospital and Institute, 52 Fucheng Road, Haidian District, Beijing 100142 (China)

    2012-08-15

    Objective: To evaluate the relationship between apparent diffusion coefficient (ADC) value and the local invasiveness of endometrial carcinoma. Methods and materials: The MR imaging of seventy-three patients with endometrial carcinoma proved by post-operative pathology and sixty-four patients with healthy uteri were retrospectively reviewed. All MR examinations included axial T2WI and T1WI, sagittal T2WI and diffusion-weighted sequences (b = 0 and b = 1000 s/mm{sup 2}). Tumor size, mean ADC value (ADCm) and quartile ADC (ADCq) were acquired on post-processing workstation using voxel-analysis software. Differences between the ADC values among three layers of normal uterine body and endometrial carcinomas were compared by ANOVA test. Groups were divided according to pathologic type, histologic grade, depth of myometrial infiltration, presence of cervical invasion and lymphovascular space invasion, and lymph node metastasis. Tumor size and ADC values were compared and analyzed. Results: ADC values were different in three zones of uterine body (P < 0.001), with the lowest in junctional zone [(1.126 {+-} 0.190) Multiplication-Sign 10{sup -3} mm{sup 2}/s] and highest in outer myometrium [(1.496 {+-} 0.196) Multiplication-Sign 10{sup -3} mm{sup 2}/s]. Mean ADC value of endometrial carcinomas [(1.011 {+-} 0.121) Multiplication-Sign 10{sup -3} mm{sup 2}/s] was lower than the normal uterine body. Quartile ADC and tumor size were greater in groups with more invasive pathologic factors (P < 0.05). Deep myometrial infiltration, cervical invasion, lymphovascular space invasion and lymph node metastasis were more common as quartile ADC values and tumor sizes increased. Conclusion: Mean ADC value was lower in endometrial carcinoma was lower than the normal uterus. Quartile ADC, representing the intra-tumor heterogeneity of water movement, had a profound relationship with invasiveness of endometrial carcinomas, while mean ADC value did not. ADC values may serve as a quantitative

  6. Determination of the diffusion coefficient of ionic species in Boom Clay by electromigration. First evaluation

    International Nuclear Information System (INIS)

    Maes, N.; Moors, H.; De Canniere, P.; Aertsens, M.; Put, M.

    1997-03-01

    Classical diffusion experiments for strongly retarded radionuclides take a very long time. The migration can be accelerated considerably by applying an electrical field across a saturated porous medium (electromigration). Under the influence of the electric field, the ions will attain a constant velocity which is related to the diffusion coefficient by the law of Einstein (V=zeED/KT). The displacement of the concentration profile is a direct measure for the diffusion coefficient. A description of the problems of pH-disturbances, electro-osmosis and dispersion is given and an the feasibility of the electromigration method is evaluated

  7. Computable error estimates for Monte Carlo finite element approximation of elliptic PDE with lognormal diffusion coefficients

    KAUST Repository

    Hall, Eric

    2016-01-09

    The Monte Carlo (and Multi-level Monte Carlo) finite element method can be used to approximate observables of solutions to diffusion equations with lognormal distributed diffusion coefficients, e.g. modeling ground water flow. Typical models use lognormal diffusion coefficients with H´ older regularity of order up to 1/2 a.s. This low regularity implies that the high frequency finite element approximation error (i.e. the error from frequencies larger than the mesh frequency) is not negligible and can be larger than the computable low frequency error. We address how the total error can be estimated by the computable error.

  8. Computational error estimates for Monte Carlo finite element approximation with log normal diffusion coefficients

    KAUST Repository

    Sandberg, Mattias

    2015-01-07

    The Monte Carlo (and Multi-level Monte Carlo) finite element method can be used to approximate observables of solutions to diffusion equations with log normal distributed diffusion coefficients, e.g. modelling ground water flow. Typical models use log normal diffusion coefficients with H¨older regularity of order up to 1/2 a.s. This low regularity implies that the high frequency finite element approximation error (i.e. the error from frequencies larger than the mesh frequency) is not negligible and can be larger than the computable low frequency error. This talk will address how the total error can be estimated by the computable error.

  9. FORTRAN program for calculating liquid-phase and gas-phase thermal diffusion column coefficients

    International Nuclear Information System (INIS)

    Rutherford, W.M.

    1980-01-01

    A computer program (COLCO) was developed for calculating thermal diffusion column coefficients from theory. The program, which is written in FORTRAN IV, can be used for both liquid-phase and gas-phase thermal diffusion columns. Column coefficients for the gas phase can be based on gas properties calculated from kinetic theory using tables of omega integrals or on tables of compiled physical properties as functions of temperature. Column coefficients for the liquid phase can be based on compiled physical property tables. Program listings, test data, sample output, and users manual are supplied for appendices

  10. Procedures and apparatus for measuring diffusion and distribution coefficients in compacted clays

    International Nuclear Information System (INIS)

    Hume, H.B.

    1993-12-01

    Diffusion and distribution coefficients are needed to assess the migration of radionuclides through the compacted clay-based buffer and backfill materials proposed for use in a nuclear fuel waste disposal vault. This report describes the techniques used to measure these coefficients. Both steady-state and transient diffusion experiments are discussed. The procedures used to prepare the clay plug, assemble the cell, conduct the experiment and calculate the results are described. In addition, methods for obtaining distribution coefficients for radionuclides on both loose and compacted clays are discussed. (author). 18 refs., 3 tabs., 16 figs

  11. Diffusion in Poiseuille and Couette flows of binary mixtures of incompressible newtonian fluids

    International Nuclear Information System (INIS)

    Caetano Filho, E.; Qassim, R.Y.

    1981-07-01

    Using the continuum theory of binary mixtures of incompressible Newtonian fluids, Poiseuille and Couette flows are studied with a view to determining whether diffusion occurs in such flows. It is shown that diffusion is absent in the Couette case. However, in Poiseuille flow there are significant differences between the velocities of the species comprising the mixture. This result is in broad agreement with that of Mills for similar mixtures of nonuniform composition. (Author) [pt

  12. Consequences of using home-made radon sources for measuring the radon diffusion coefficient

    International Nuclear Information System (INIS)

    Dobrovolny, T.; Jiranek, M.

    2017-01-01

    The applicability of home-made radon sources for determining the radon diffusion coefficient of waterproofing materials was studied for three representatives of materials with a high radium content: uraninite, slag concrete and filter sand. The results of our investigation confirmed that the radon production rate of home-made radon sources is significantly lower than the radon production rate of artificial sources. Consequently, home-made sources are usually unable to generate concentrations higher than 100 kBq/m 3 in the source container. Therefore, they cannot be used for determining radon diffusion coefficients lower than 1 x 10 -12 m 2 /s. In addition, when home-made radon sources are used, only time-dependent mathematical solutions of the non-stationary radon diffusion can be used for determining the radon diffusion coefficient from the measured data. (authors)

  13. The Diffusion Coefficients Of Cu And Zn In amp913- And amp919- Solid Solutions

    Directory of Open Access Journals (Sweden)

    Adhurim Hoxha

    2015-06-01

    Full Text Available Abstract In this work the multiphase diffusion in the infinite couple Cu-Zn was studied experimentally. The diffusion couples were prepared by platting technique. The samples were annealed in three different temperatures which were taken below the melting temperature of Zn. For each temperature there were used six different annealing times ranging from 1h up to 32h. In the micrographs provided by light microscopy it can be seen the formation of only two of the three intermetalic phases present in the Cu-Zn phase diagram namely amp949- and amp947-phase. WDX EPMA analysis was used to obtain the concentration profiles of the diffusion layers.he diffusion coefficients of Cu and Zn in amp945- and amp951-solid solutions are calculated using the solutions of second Ficks law for independent concentration case. Since the diffusion coefficients depends only on the temperature of annealing and not on the time of it they must be the same for a given temperature. Therefore the diffusion coefficients were averaged for each temperature. Knowing the diffusion coefficients for each temperature enables the calculation of the activation energies and the frequency factors as well.

  14. A new consistent definition of the homogenized diffusion coefficient of a lattice, limitations of the homogenization concept, and discussion of previously defined coefficients

    International Nuclear Information System (INIS)

    Deniz, V.C.

    1980-01-01

    The problem concerned with the correct definition of the homogenized diffusion coefficient of a lattice, and the concurrent problem of whether or not a homogenized diffusion equation can be formally set up, is studied by a space-energy-angle dependent treatment for a general lattice cell using an operator notation which applies to any eigen-problem. A new definition of the diffusion coefficient is given, which combines within itself the individual merits of the two definitions of Benoist. The relation between the new coefficient and the ''uncorrected'' Benoist coefficient is discussed by considering continuous-spectrum and multi-group diffusion equations. Other definitions existing in the literature are briefly discussed. It is concluded that a diffusion coefficient should represent only leakage effects. A comparison is made between the homogenization approach and the approach via eigen-coefficients, and brief indications are given of a possible scheme for the latter. (author)

  15. Eddy diffusion coefficients and their upper limits based on application of the similarity theory

    Directory of Open Access Journals (Sweden)

    M. N. Vlasov

    2015-07-01

    Full Text Available The equation for the diffusion velocity in the mesosphere and the lower thermosphere (MLT includes the terms for molecular and eddy diffusion. These terms are very similar. For the first time, we show that, by using the similarity theory, the same formula can be obtained for the eddy diffusion coefficient as the commonly used formula derived by Weinstock (1981. The latter was obtained by taking, as a basis, the integral function for diffusion derived by Taylor (1921 and the three-dimensional Kolmogorov kinetic energy spectrum. The exact identity of both formulas means that the eddy diffusion and heat transport coefficients used in the equations, both for diffusion and thermal conductivity, must meet a criterion that restricts the outer eddy scale to being much less than the scale height of the atmosphere. This requirement is the same as the requirement that the free path of molecules must be much smaller than the scale height of the atmosphere. A further result of this criterion is that the eddy diffusion coefficients Ked, inferred from measurements of energy dissipation rates, cannot exceed the maximum value of 3.2 × 106 cm2 s−1 for the maximum value of the energy dissipation rate of 2 W kg−1 measured in the mesosphere and the lower thermosphere (MLT. This means that eddy diffusion coefficients larger than the maximum value correspond to eddies with outer scales so large that it is impossible to use these coefficients in eddy diffusion and eddy heat transport equations. The application of this criterion to the different experimental data shows that some reported eddy diffusion coefficients do not meet this criterion. For example, the large values of these coefficients (1 × 107 cm2 s−1 estimated in the Turbulent Oxygen Mixing Experiment (TOMEX do not correspond to this criterion. The Ked values inferred at high latitudes by Lübken (1997 meet this criterion for summer and winter polar data, but the Ked values for summer at low latitudes

  16. Radon diffusion coefficients for soils. Previous studies and their application to uranium-bearing wastes

    International Nuclear Information System (INIS)

    Sasaki, Tomozo; Gunji, Yasuyoshi; Iida, Takao

    2008-01-01

    Radon diffusion in soils has been studied over the years by many researchers. The application of such studies to the evaluation of radiation exposure caused by radon from uranium-bearing wastes disposed in a shallow land site is very important. The present paper surveyed closely relevant studies and elucidated the inherent nature of radon diffusion in terms of the definition of radon diffusion coefficients. Then, basic features of measurement methods for determining radon diffusion coefficients in soils were explained. Furthermore, theoretical aspects of radon diffusion in soils were discussed in terms of microscopic radon diffusion in soils and large-scale radon diffusion through cover soil defects for uranium mill tailings. Finally, in order to apply the radon diffusion studies to uranium-bearing waste disposal in shallow land sites, new challenges were presented: elucidation of radon diffusion in uranium-bearing wastes and cover-soil cracks, and demonstration of the validity of applying only radon diffusion in the evaluation of radiation exposure caused by radon, which would come through Japanese cover soils for uranium-bearing waste disposal. (author)

  17. Sedimentation-diffusion equilibrium of binary mixtures of charged colloids including volume effects

    NARCIS (Netherlands)

    Biesheuvel, P.M.; Lyklema, J.

    2005-01-01

    We describe the sedimentation-diffusion equilibrium of binary mixtures of charged colloids in the presence of small ions and for non-dilute conditions, by extending the work of Biben and Hansen (1994 J. Phys.: Condens. Matter 6 A345). For a monocomponent system, they included a Carnahan-Starling

  18. Interaction between lactose and cadmium chloride in aqueous solutions as seen by diffusion coefficients measurements

    International Nuclear Information System (INIS)

    Verissimo, Luis M.P.; Gomes, Joselaine C.S.; Romero, Carmen; Esteso, Miguel A.; Sobral, Abilio J.F.N.; Ribeiro, Ana C.F.

    2013-01-01

    Highlights: ► Diffusion coefficients of aqueous systems containing lactose and cadmium chloride. ► Influence of the lactose on the diffusion of cadmium chloride. ► Interactions between Cd 2+ and lactose. -- Abstract: Diffusion coefficients of an aqueous system containing cadmium chloride 0.100 mol · dm −3 and lactose at different concentrations at 25 °C have been measured, using a conductimetric cell and an automatic apparatus to follow diffusion. The cell relies on an open-ended capillary method and a conductimetric technique is used to follow the diffusion process by measuring the resistance of a solution inside the capillaries, at recorded times. From these results and by ab initio calculations, it was possible to obtain a better understanding of the effect of lactose on transport of cadmium chloride in aqueous solutions

  19. Rapid yet accurate measurement of mass diffusion coefficients by phase shifting interferometer

    CERN Document Server

    Guo Zhi Xiong; Komiya, A

    1999-01-01

    The technique of using a phase-shifting interferometer is applied to the study of diffusion in transparent liquid mixtures. A quick method is proposed for determining the diffusion coefficient from the measurements of the location of fringes on a grey level picture. The measurement time is very short (within 100 s) and a very small transient diffusion field can be observed and recorded accurately with a rate of 30 frames per second. The measurement can be completed using less than 0.12 cc of solutions. The influence of gravity on the measurement of the diffusion coefficient is eliminated in the present method. Results on NaCl-water diffusion systems are presented and compared with the reference data. (author)

  20. Exciton diffusion coefficient measurement in ZnO nanowires under electron beam irradiation

    Science.gov (United States)

    Donatini, Fabrice; Pernot, Julien

    2018-03-01

    In semiconductor nanowires (NWs) the exciton diffusion coefficient can be determined using a scanning electron microscope fitted with a cathodoluminescence system. High spatial and temporal resolution cathodoluminescence experiments are needed to measure independently the exciton diffusion length and lifetime in single NWs. However, both diffusion length and lifetime can be affected by the electron beam bombardment during observation and measurement. Thus, in this work the exciton lifetime in a ZnO NW is measured versus the electron beam dose (EBD) via a time-resolved cathodoluminescence experiment with a temporal resolution of 50 ps. The behavior of the measured exciton lifetime is consistent with our recent work on the EBD dependence of the exciton diffusion length in similar NWs investigated under comparable SEM conditions. Combining the two results, the exciton diffusion coefficient in ZnO is determined at room temperature and is found constant over the full span of EBD.

  1. Permeability and Diffusion Coefficients of Single Methyl Lactate Enantiomers in Nafion® and Cellophane Membranes Measured in Diffusion Cell.

    Czech Academy of Sciences Publication Activity Database

    Hovorka, Š.; Randová, A.; Borbášová, T.; Sysel, P.; Vychodilová, Hana; Červenková Šťastná, Lucie; Brožová, Libuše; Žitka, Jan; Storch, Jan; Kačírková, Marie; Drašar, P.; Izák, Pavel

    2016-01-01

    Roč. 158, JAN 28 (2016), s. 322-332 ISSN 1383-5866 R&D Projects: GA ČR(CZ) GAP106/12/0569 Institutional support: RVO:67985858 ; RVO:61389013 Keywords : diffusion coefficient measurement * permeability * nafion * cellophane * chirality of polymer membrane Subject RIV: CI - Industrial Chemistry, Chemical Engineering Impact factor: 3.359, year: 2016

  2. Diffusion coefficients of nickel chloride in aqueous solutions of lactose at T = 298.15 K and T = 310.15 K

    International Nuclear Information System (INIS)

    Ribeiro, Ana C.F.; Gomes, Joselaine C.S.; Barros, Marisa C.F.; Lobo, Victor M.M.; Esteso, Miguel A.

    2011-01-01

    Binary mutual diffusion coefficients (interdiffusion coefficients) of nickel chloride in water at T = 298.15 K and T = 310.15 K, and at concentrations between (0.000 and 0.100) mol · dm -3 , using a Taylor dispersion method have been measured. These data are discussed on the basis of the Onsager-Fuoss and Pikal models. The equivalent conductance at infinitesimal concentration of the nickel ion in these solutions at T = 310.15 K has been estimated using these results. Through the same technique, ternary mutual diffusion coefficients (D 11 , D 22 , D 12 , and D 21 ) for aqueous solutions containing NiCl 2 and lactose, at T = 298.15 K and T = 310.15 K, and at different carrier concentrations were also measured. These data permit us to have a better understanding of the structure of these systems and the thermodynamic behaviour of NiCl 2 in different media.

  3. Radon diffusion coefficients in 360 waterproof materials of different chemical composition.

    Science.gov (United States)

    Jiránek, M; Kotrbatá, M

    2011-05-01

    This paper summarises the results of radon diffusion coefficient measurements in 360 common waterproof materials available throughout Europe. The materials were grouped into 26 categories according to their chemical composition. It was found that the diffusion coefficients of materials used for protecting houses against radon vary within eight orders from 10(-15) to 10(-8) m(2) s(-1). The lowest values were obtained for bitumen membranes with an Al carrier film and for ethylene vinyl acetate membranes. The highest radon diffusion coefficient values were discovered for sodium bentonite membranes, rubber membranes made of ethylene propylene diene monomer and polymer cement coatings. The radon diffusion coefficients for waterproofings widely used for protecting houses, i.e. flexible polyvinyl chloride, high-, low-density polyethylene, polypropylene and bitumen membranes, vary in the range from 3 × 10(-12) to 3 × 10(-11) m(2) s(-1). Tests were performed which confirmed that the radon diffusion coefficient is also an effective tool for verifying the air-tightness of joints.

  4. The Influence of Conditioning Agent on Phosphate Diffusion Coefficient through Polyacrylamide and Agarose Gel

    Directory of Open Access Journals (Sweden)

    Layta Dinira

    2013-03-01

    Full Text Available Excess phosphate in natural water can cause algae grow rapidly, to the extent causing many fish deaths that led to the extinction of certain species. Therefore, an analysis or periodic observations of phosphate levels in the water is needed. The commonly used method is diffusive gradient in thin films (DGT technique. The DGT technique is based on the ability of analyte to diffuse through a gel, which have a value named diffusion coefficient. This research was conducted in order to study the effect of different storage solution to the phosphate diffusion coefficient through polyacrylamide and agarose gels. Initial research performed with making the polyacrylamide and agarose gels. To observe the effect of different storage solutions, the gels partly stored in distilled water gel while the others are stored in a NaCl solution of 0.01 M. Phosphate diffusion coefficient was determined using Fick's Law after analyze the phosphate concentration using UV-Visible spectrophotometer. The results showed that phosphate diffusion coefficient was highest when polyacrylamide and agarose gels stored in NaCl solution of 0.01 M.

  5. Diffusion coefficients of tracers in glassy polymer systems prepared by gamma radiolysis

    International Nuclear Information System (INIS)

    Tonge, M.P.; Gilbert, R.G.

    1996-01-01

    Diffusion-controlled reactions are common in free radical polymerisation reactions, especially in glassy polymer matrices. Such reactions commonly have an important influence on the polymerisation process and final polymer properties. For example, the dominant growth-stopping event (bimolecular termination) is generally diffusion-controlled. In glassy polymer systems, where molecular mobility is very low, the chain growth mechanism (propagation) may become diffusion-controlled. At present, the mechanism for propagation in glassy polymers is poorly understood, but it is expected by the Smoluchowski expression applied to propagation to depend strongly on the diffusion coefficient of monomer. The objective of this study is to measure reliable diffusion coefficients of small tracer molecules in glassy polymers, and compare these with propagation rate coefficients in similar systems, by the prediction above. Samples were initially prepared in a sealed sampled cell containing monomer, inert diluent, and tracer dye. After irradiation for several days, complete conversion of monomer to polymer can be obtained. The diffusion coefficients for two tracer dyes have been measured as a function of weight fraction polymer glassy poly(methyl methacrylate) samples

  6. Perpendicular Diffusion Coefficient of Comic Rays: The Presence of Weak Adiabatic Focusing

    Science.gov (United States)

    Wang, J. F.; Qin, G.; Ma, Q. M.; Song, T.; Yuan, S. B.

    2017-08-01

    The influence of adiabatic focusing on particle diffusion is an important topic in astrophysics and plasma physics. In the past, several authors have explored the influence of along-field adiabatic focusing on the parallel diffusion of charged energetic particles. In this paper, using the unified nonlinear transport theory developed by Shalchi and the method of He and Schlickeiser, we derive a new nonlinear perpendicular diffusion coefficient for a non-uniform background magnetic field. This formula demonstrates that the particle perpendicular diffusion coefficient is modified by along-field adiabatic focusing. For isotropic pitch-angle scattering and the weak adiabatic focusing limit, the derived perpendicular diffusion coefficient is independent of the sign of adiabatic focusing characteristic length. For the two-component model, we simplify the perpendicular diffusion coefficient up to the second order of the power series of the adiabatic focusing characteristic quantity. We find that the first-order modifying factor is equal to zero and that the sign of the second order is determined by the energy of the particles.

  7. Perpendicular Diffusion Coefficient of Comic Rays: The Presence of Weak Adiabatic Focusing

    International Nuclear Information System (INIS)

    Wang, J. F.; Ma, Q. M.; Song, T.; Yuan, S. B.; Qin, G.

    2017-01-01

    The influence of adiabatic focusing on particle diffusion is an important topic in astrophysics and plasma physics. In the past, several authors have explored the influence of along-field adiabatic focusing on the parallel diffusion of charged energetic particles. In this paper, using the unified nonlinear transport theory developed by Shalchi and the method of He and Schlickeiser, we derive a new nonlinear perpendicular diffusion coefficient for a non-uniform background magnetic field. This formula demonstrates that the particle perpendicular diffusion coefficient is modified by along-field adiabatic focusing. For isotropic pitch-angle scattering and the weak adiabatic focusing limit, the derived perpendicular diffusion coefficient is independent of the sign of adiabatic focusing characteristic length. For the two-component model, we simplify the perpendicular diffusion coefficient up to the second order of the power series of the adiabatic focusing characteristic quantity. We find that the first-order modifying factor is equal to zero and that the sign of the second order is determined by the energy of the particles.

  8. Perpendicular Diffusion Coefficient of Comic Rays: The Presence of Weak Adiabatic Focusing

    Energy Technology Data Exchange (ETDEWEB)

    Wang, J. F.; Ma, Q. M.; Song, T.; Yuan, S. B. [Research Department of Biomedical Engineering, Institute of Electrical Engineering, Chinese Academy of Science, Beijing 100190 (China); Qin, G., E-mail: wangjunfang@mail.iee.ac.cn, E-mail: qingang@hit.edu.cn [School of Science, Harbin Institute of Technology, Shenzhen 518055 (China)

    2017-08-20

    The influence of adiabatic focusing on particle diffusion is an important topic in astrophysics and plasma physics. In the past, several authors have explored the influence of along-field adiabatic focusing on the parallel diffusion of charged energetic particles. In this paper, using the unified nonlinear transport theory developed by Shalchi and the method of He and Schlickeiser, we derive a new nonlinear perpendicular diffusion coefficient for a non-uniform background magnetic field. This formula demonstrates that the particle perpendicular diffusion coefficient is modified by along-field adiabatic focusing. For isotropic pitch-angle scattering and the weak adiabatic focusing limit, the derived perpendicular diffusion coefficient is independent of the sign of adiabatic focusing characteristic length. For the two-component model, we simplify the perpendicular diffusion coefficient up to the second order of the power series of the adiabatic focusing characteristic quantity. We find that the first-order modifying factor is equal to zero and that the sign of the second order is determined by the energy of the particles.

  9. Assessment of passive muscle elongation using Diffusion Tensor MRI : Correlation between fiber length and diffusion coefficients

    NARCIS (Netherlands)

    Mazzoli, Valentina; Oudeman, Jos; Nicolay, Klaas; Maas, Mario; Verdonschot, Nico; Sprengers, Andre M.; Nederveen, Aart J.; Froeling, Martijn; Strijkers, Gustav J.

    2016-01-01

    In this study we investigated the changes in fiber length and diffusion parameters as a consequence of passive lengthening and stretching of the calf muscles. We hypothesized that changes in radial diffusivity (RD) are caused by changes in the muscle fiber cross sectional area (CSA) as a consequence

  10. Assessment of passive muscle elongation using Diffusion Tensor MRI: Correlation between fiber length and diffusion coefficients

    NARCIS (Netherlands)

    Mazzoli, Valentina; Oudeman, Jos; Nicolay, Klaas; Maas, Mario; Verdonschot, Nico; Sprengers, Andre M.; Nederveen, Aart J.; Froeling, Martijn; Strijkers, Gustav J.

    2016-01-01

    In this study we investigated the changes in fiber length and diffusion parameters as a consequence of passive lengthening and stretching of the calf muscles. We hypothesized that changes in radial diffusivity (RD) are caused by changes in the muscle fiber cross sectional area (CSA) as a consequence

  11. Modelling of kinetics of diffusive phase transformation in binary systems with multiple stoichiometric phases

    Czech Academy of Sciences Publication Activity Database

    Svoboda, Jiří; Gamsjäger, E.; Fischer, F. D.; Kozeschnik, E.

    2006-01-01

    Roč. 27, č. 6 (2006), s. 622-628 ISSN 1547-7037 R&D Projects: GA AV ČR IAA200410601 Institutional research plan: CEZ:AV0Z20410507 Keywords : diffusion modelling * diffusivity coefficient * intrmetallic compound Subject RIV: JG - Metallurgy Impact factor: 0.427, year: 2006

  12. Mutual diffusion coefficients of L-glutamic acid and monosodium L-glutamate in aqueous solutions at T = 298.15 K

    International Nuclear Information System (INIS)

    Ribeiro, Ana C.F.; Rodrigo, M.M.; Barros, Marisa C.F.; Verissimo, Luis M.P.; Romero, Carmen; Valente, Artur J.M.; Esteso, Miguel A.

    2014-01-01

    Highlights: • Interdiffusion coefficients of L-glutamic acid and sodium L-glutamate were measured. • The L-glutamic acid behaves as a monoprotic weak acid. • The sodium L-glutamate shows a symmetrical 1:1 non-associated behaviour. • Limiting diffusion coefficients and ionic conductivities were estimated. • Diffusion coefficients were discussed on the basis of the Onsager–Fuoss equations. - Abstract: Mutual diffusion coefficient values for binary aqueous solutions of both L-glutamic acid (H 2 Glu) and sodium L-glutamate (NaHGlu) were measured with the Taylor dispersion technique, at T = 298.15 K, and concentrations ranging from (0.001 to 0.100) mol · dm −3 . The results were discussed on the basis of the Onsager–Fuoss and the Nernst theoretical equations, by considering the H 2 Glu as a weak acid (monoprotic acid, with K 2 = 5.62 · 10 −5 ). The smaller values found for the acid with respect to those of the salt, confirm this association hypothesis. From the diffusion coefficient values at infinitesimal concentration, limiting ionic conductivities as well as the hydrodynamic radius of the hydrogen glutamate ion (HGlu − ) were derived and analyzed in terms of the chain methylene groups. The effect of different phenomena, such as association or complexation, were also taken into consideration and discussed. Values for the dissociation degree for H 2 Glu were also estimated

  13. New method and installation for rapid determination of radon diffusion coefficient in various materials.

    Science.gov (United States)

    Tsapalov, Andrey; Gulabyants, Loren; Livshits, Mihail; Kovler, Konstantin

    2014-04-01

    The mathematical apparatus and the experimental installation for the rapid determination of radon diffusion coefficient in various materials are developed. The single test lasts not longer than 18 h and allows testing numerous materials, such as gaseous and liquid media, as well as soil, concrete and radon-proof membranes, in which diffusion coefficient of radon may vary in an extremely wide range, from 1·10(-12) to 5·10(-5) m(2)/s. The uncertainty of radon diffusion coefficient estimation depends on the permeability of the sample and varies from about 5% (for the most permeable materials) to 40% (for less permeable materials, such as radon-proof membranes). Copyright © 2014. Published by Elsevier Ltd.

  14. The Measurement of Polymer Swelling Processes by an Interferometric Method and Evaluation of Diffusion Coefficients

    Directory of Open Access Journals (Sweden)

    Aleš Mráček

    2010-02-01

    Full Text Available The amorphous polymer film swelling in a liquid solvent below the glass transition temperature was characterized by a few kinetic parameters (especially the mutual diffusion coefficient of swelling and its mean value obtained by interference of monochromatic light in the wedge arrangement. This interferometric method allows one to determine the concentration field in the swollen surface layer and consequently to compute the concentration-dependent diffusion coefficient. A software system developed at the Department of Physics and Material Engineering at TBU in Zlin has been used for the evaluation of the main kinetic parameters of the swelling process. The software can be used for the on-line analyses of interferograms during the swelling process. The main application outputs are the computation of the concentration profile, the concentration gradient, the mutual diffusion coefficient of the swelling by the solvent and its mean value.

  15. Non-destructive testing method for determining the solvent diffusion coefficient in the porous materials products

    Science.gov (United States)

    Belyaev, V. P.; Mishchenko, S. V.; Belyaev, P. S.

    2018-01-01

    Ensuring non-destructive testing of products in industry is an urgent task. Most of the modern methods for determining the diffusion coefficient in porous materials have been developed for bodies of a given configuration and size. This leads to the need for finished products destruction to make experimental samples from them. The purpose of this study is the development of a dynamic method that allows operatively determine the diffusion coefficient in finished products from porous materials without destroying them. The method is designed to investigate the solvents diffusion coefficient in building constructions from materials having a porous structure: brick, concrete and aerated concrete, gypsum, cement, gypsum or silicate solutions, gas silicate blocks, heat insulators, etc. A mathematical model of the method is constructed. The influence of the design and measuring device operating parameters on the method accuracy is studied. The application results of the developed method for structural porous products are presented.

  16. Crack diffusion coefficient - A candidate fracture toughness parameter for short fiber composites

    Science.gov (United States)

    Mull, M. A.; Chudnovsky, A.; Moet, A.

    1987-01-01

    In brittle matrix composites, crack propagation occurs along random trajectories reflecting the heterogeneous nature of the strength field. Considering the crack trajectory as a diffusive process, the 'crack diffusion coefficient' is introduced. From fatigue crack propagation experiments on a set of identical SEN polyester composite specimens, the variance of the crack tip position along the loading axis is found to be a linear function of the effective 'time'. The latter is taken as the effective crack length. The coefficient of proportionality between variance of the crack trajectory and the effective crack length defines the crack diffusion coefficient D which is found in the present study to be 0.165 mm. This parameter reflects the ability of the composite to deviate the crack from the energetically most efficient path and thus links fracture toughness to the microstructure.

  17. Diffusion coefficients of gaseous scavengers in organic liquids used in radiation chemistry

    International Nuclear Information System (INIS)

    Luthjens, L.H.; De Leng, H.C.; Warman, J.M.; Hummel, A.

    1990-01-01

    Diffusion coefficients have been measured of some gaseous scavengers commonly used in radiation chemical studies: CO 2 , NH 3 , SF 6 and O 2 in trans-decalin, cyclohexane, isooctane and n-hexane, and CO 2 in cis-decalin, at 25 0 C. A modified diaphragm cell method has been used in order to limit the time needed for a measurement to about 6 h. Analysis of the results yields a simple semi-empirical predictive relation for the diffusion coefficient of a (gaseous) solute A in an organic solvent B. Diffusion coefficients calculated using the simple relation appear to give results in fair agreement with published values, over a range of organic solvents including alcohols, and over a range of temperatures. Some measured and predicted values are discussed with reference to results from the literature. (author)

  18. Modifying JPEG binary arithmetic codec for exploiting inter/intra-block and DCT coefficient sign redundancies.

    Science.gov (United States)

    Lakhani, Gopal

    2013-04-01

    This article presents four modifications to the JPEG arithmetic coding (JAC) algorithm, a topic not studied well before. It then compares the compression performance of the modified JPEG with JPEG XR, the latest block-based image coding standard. We first show that the bulk of inter/intra-block redundancy, caused due to the use of the block-based approach by JPEG, can be captured by applying efficient prediction coding. We propose the following modifications to JAC to take advantages of our prediction approach. 1) We code a totally different DC difference. 2) JAC tests a DCT coefficient by considering its bits in the increasing order of significance for coding the most significant bit position. It causes plenty of redundancy because JAC always begins with the zeroth bit. We modify this coding order and propose alternations to the JPEG coding procedures. 3) We predict the sign of significant DCT coefficients, a problem is not addressed from the perspective of the JPEG decoder before. 4) We reduce the number of binary tests that JAC codes to mark end-of-block. We provide experimental results for two sets of eight-bit gray images. The first set consists of nine classical test images mostly of size 512 × 512 pixels. The second set consists of 13 images of size 2000 × 3000 pixels or more. Our modifications to JAC obtain extra-ordinary amount of code reduction without adding any kind of losses. More specifically, when we quantize the images using the default quantizers, our modifications reduce the total JAC code size of the images of these two sets by about 8.9 and 10.6%, and the JPEG Huffman code size by about 16.3 and 23.4%, respectively, on the average. Gains are even higher for coarsely quantized images. Finally, we compare the modified JAC with two settings of JPEG XR, one with no block overlapping and the other with the default transform (we denote them by JXR0 and JXR1, respectively). Our results show that for the finest quality rate image coding, the modified

  19. Banded structures in electron pitch angle diffusion coefficients from resonant wave-particle interactions

    Energy Technology Data Exchange (ETDEWEB)

    Tripathi, A. K., E-mail: aktrip2001@yahoo.co.in; Singhal, R. P., E-mail: rpsiitbhu@yahoo.com [Department of Physics, Indian Institute of Technology (Banaras Hindu University), Varanasi, Uttar Pradesh (India); Khazanov, G. V., E-mail: George.V.Khazanov@nasa.gov [NASA Goddard Space Flight Center, Greenbelt, Maryland 20771 (United States); Avanov, L. A., E-mail: levon.a.avanov@nasa.gov [NASA Goddard Space Flight Center, Greenbelt, Maryland 20771 (United States); Department of Astronomy, University of Maryland, College Park, Maryland 20742 (United States)

    2016-04-15

    Electron pitch angle (D{sub αα}) and momentum (D{sub pp}) diffusion coefficients have been calculated due to resonant interactions with electrostatic electron cyclotron harmonic (ECH) and whistler mode chorus waves. Calculations have been performed at two spatial locations L = 4.6 and 6.8 for electron energies ≤10 keV. Landau (n = 0) resonance and cyclotron harmonic resonances n = ±1, ±2, … ±5 have been included in the calculations. It is found that diffusion coefficient versus pitch angle (α) profiles show large dips and oscillations or banded structures. The structures are more pronounced for ECH and lower band chorus (LBC) and particularly at location 4.6. Calculations of diffusion coefficients have also been performed for individual resonances. It is noticed that the main contribution of ECH waves in pitch angle diffusion coefficient is due to resonances n = +1 and n = +2. A major contribution to momentum diffusion coefficients appears from n = +2. However, the banded structures in D{sub αα} and D{sub pp} coefficients appear only in the profile of diffusion coefficients for n = +2. The contribution of other resonances to diffusion coefficients is found to be, in general, quite small or even negligible. For LBC and upper band chorus waves, the banded structures appear only in Landau resonance. The D{sub pp} diffusion coefficient for ECH waves is one to two orders smaller than D{sub αα} coefficients. For chorus waves, D{sub pp} coefficients are about an order of magnitude smaller than D{sub αα} coefficients for the case n ≠ 0. In case of Landau resonance, the values of D{sub pp} coefficient are generally larger than the values of D{sub αα} coefficients particularly at lower energies. As an aid to the interpretation of results, we have also determined the resonant frequencies. For ECH waves, resonant frequencies have been estimated for wave normal angle 89° and harmonic resonances n = +1, +2, and +3

  20. Measurement of the local particle diffusion coefficient in a magnetized plasma

    International Nuclear Information System (INIS)

    Meyerhofer, D.D.; Levinton, F.M.

    1987-02-01

    Local impurity particle diffusion coefficients have been measured in a low temperature plasma by the injection of test particles at the center of the plasma. The injection is accomplished by a high voltage discharge between two small graphite electrodes on a probe. The probe can be located anywhere in the plasma. The diffusion is observed spectroscopically. An analysis of the spatial and temporal evolution of the CII radiation from the carbon discharge can determine the parallel and perpendicular diffusion of the impurity ions. Results with the diagnostic have been obtained in the Proto S-1/C spheromak. The measured value of the diffusion coefficient in the afterglow plasma is in good agreement with classical predictions

  1. Field-Scale Effective Matrix Diffusion Coefficient for FracturedRock: Results From Literature Survey

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Quanlin; Liu, Hui Hai; Molz, Fred J.; Zhang, Yingqi; Bodvarsson, Gudmundur S.

    2005-03-28

    Matrix diffusion is an important mechanism for solutetransport in fractured rock. We recently conducted a literature survey onthe effective matrix diffusion coefficient, Dem, a key parameter fordescribing matrix diffusion processes at the field scale. Forty fieldtracer tests at 15 fractured geologic sites were surveyed and selectedfor study, based on data availability and quality. Field-scale Dem valueswere calculated, either directly using data reported in the literature orby reanalyzing the corresponding field tracer tests. Surveyed dataindicate that the effective-matrix-diffusion-coefficient factor FD(defined as the ratio of Dem to the lab-scale matrix diffusioncoefficient [Dem]of the same tracer) is generally larger than one,indicating that the effective matrix diffusion coefficient in the fieldis comparatively larger than the matrix diffusion coefficient at therock-core scale. This larger value could be attributed to the manymass-transfer processes at different scales in naturally heterogeneous,fractured rock systems. Furthermore, we observed a moderate trend towardsystematic increase in the emDFmDDF value with observation scale,indicating that the effective matrix diffusion coefficient is likely tobe statistically scale dependent. The FD value ranges from 1 to 10,000for observation scales from 5 to 2,000 m. At a given scale, the FD valuevaries by two orders of magnitude, reflecting the influence of differingdegrees of fractured rock heterogeneity at different sites. In addition,the surveyed data indicate that field-scale longitudinal dispersivitygenerally increases with observation scale, which is consistent withprevious studies. The scale-dependent field-scale matrix diffusioncoefficient (and dispersivity) may have significant implications forassessing long-term, large-scale radionuclide and contaminant transportevents in fractured rock, both for nuclear waste disposal and contaminantremediation.

  2. Diffusion coefficients of rare earth elements in fcc Fe: A first-principles study

    Science.gov (United States)

    Wang, Haiyan; Gao, Xueyun; Ren, Huiping; Chen, Shuming; Yao, Zhaofeng

    2018-01-01

    The diffusion data and corresponding detailed insights are particularly important for the understanding of the related kinetic processes in Fe based alloys, e.g. solute strengthening, phase transition, solution treatment etc. We present a density function theory study of the diffusivity of self and solutes (La, Ce, Y and Nb) in fcc Fe. The five-frequency model was employed to calculate the microscopic parameters in the correlation factors of the solute diffusion. The interactions of the solutes with the first nearest-neighbor vacancy (1nn) are all attractive, and can be well understood on the basis of the combination of the strain-relief effects and the electronic effects. It is found that among the investigated species, Ce is the fastest diffusing solute in fcc Fe matrix followed by Nb, and the diffusion coefficients of these two solutes are about an order of magnitude higher than that of Fe self-diffusion. And the results show that the diffusion coefficient of La is slightly higher than that of Y, and both species are comparable to that of Fe self-diffusion.

  3. Diffusion coefficient

    Indian Academy of Sciences (India)

    kbhattacharjee

    Live Cell Imaging: Seeing inside a cell. • Cell: ~20,000 nm ~ 100 times bigger than focus. • Label different parts of a cell with fluorescent dye. • Cancer Cell: How different from a normal cell? cell. Space & time resolution ...

  4. Estimating Outer Zone Radial Diffusion Coefficients from Drift Scale Fluctuations in Van Allen Particle Data

    Science.gov (United States)

    O'Brien, T. P., III; Claudepierre, S. G.

    2017-12-01

    During geomagnetic storms, the Earth's outer radiation belt experiences enhanced radial transport. This transport occurs via phase-dependent radial displacements of particles, either by impulsive events or drift resonant waves. Because transport is phase dependent, it produces drift phase bunching, which can be observed with in situ particle detectors. We provide bounds on the radial diffusion coefficients derived from this drift phase structure as seen by NASA's Van Allen Probes. We compare these bounds to published radial diffusion coefficient models, particularly those derived independently from electromagnetic field observations.

  5. On a new procedure for determining the diffusion coefficients of swarm electrons

    International Nuclear Information System (INIS)

    Winkler, R.; Wilhelm, J.; Braglia, G.L.

    1985-01-01

    A new method for solving the Boltzmann kinetic equation applied to the determination of diffusion coefficients of swarm electrons in a model plasma, and CO 2 and N 2 plasmas is proposed. The method which uses Legendre polynomial expansion of the electron velocity distribution of the stationary and homogeneous plasma, is based upon an analytical isolation of the non-singular part of the general solution from the singular part. The converged values of the diffusion coefficients given by the new method are compared with the results of Monte-Carlo simulations. (D.Gy.)

  6. Effective diffusion coefficients for methanol in sulfuric acid solutions measured by Raman spectroscopy.

    Science.gov (United States)

    Van Loon, Lisa L; Allen, Heather C; Wyslouzil, Barbara E

    2008-10-30

    The diffusion of methanol into 0-96.5 wt % sulfuric acid solutions was followed using Raman spectroscopy. Because methanol reacts to form protonated methanol (CH 3OH 2 (+)) and methyl hydrogen sulfate in H 2SO 4 solutions, the reported diffusion coefficients, D, are effective diffusion coefficients that include all of the methyl species diffusing into H 2SO 4. The method was first verified by measuring D for methanol into water. The value obtained here, D = (1.4 +/- 0.6) x 10 (-5) cm (2)/s, agrees well with values found in the literature. The values of D in 39.2-96.5 wt % H 2SO 4 range from (0.11-0.3) x 10 (-5) cm (2)/s, with the maximum value of D occurring for 61.6 wt % H 2SO 4. The effective diffusion coefficients do not vary systematically with the viscosity of the solutions, suggesting that the speciation of both methanol and sulfuric acid may be important in determining these transport coefficients.

  7. FIELD-SCALE EFFECTIVE MATRIX DIFFUSION COEFFICIENT FOR FRACTURED ROCK:RESULTS FROM LITERATURE SURVEY

    Energy Technology Data Exchange (ETDEWEB)

    Q. Zhou; Hui-Hai Liu; F.J. Molz; Y. Zhang; G.S. Bodvarsson

    2005-04-08

    Matrix diffusion is an important mechanism for solute transport in fractured rock. We recently conducted a literature survey on the effective matrix diffusion coefficient, D{sub m}{sup e}, a key parameter for describing matrix diffusion processes at the field scale. Forty field tracer tests at 15 fractured geologic sites were surveyed and selected for the study, based on data availability and quality. Field-scale D{sub m}{sup e} values were calculated, either directly using data reported in the literature or by reanalyzing the corresponding field tracer tests. Surveyed data indicate that the effective-matrix-diffusion-coefficient factor F{sub D} (defined as the ratio of D{sub m}{sup e} to the lab-scale matrix diffusion coefficient [D{sub m}] of the same tracer) is generally larger than one, indicating that the effective matrix diffusion coefficient in the field is comparatively larger than the matrix diffusion coefficient at the rock-core scale. This larger value can be attributed to the many mass-transfer processes at different scales in naturally heterogeneous, fractured rock systems. Furthermore, we observed a moderate trend toward systematic increase in the F{sub D} value with observation scale, indicating that the effective matrix diffusion coefficient is likely to be statistically scale dependent. The F{sub D} value ranges from 1 to 10,000 for observation scales from 5 to 2,000 m. At a given scale, the F{sub D} value varies by two orders of magnitude, reflecting the influence of differing degrees of fractured rock heterogeneity at different sites. In addition, the surveyed data indicate that field-scale longitudinal dispersivity generally increases with observation scale, which is consistent with previous studies. The scale-dependent field-scale matrix diffusion coefficient (and dispersivity) may have significant implications for assessing long-term, large-scale radionuclide and contaminant transport events in fractured rock, both for nuclear waste disposal

  8. Determination of Concentration Dependent Diffusion Coefficients of Carbon in Expanded Austenite

    DEFF Research Database (Denmark)

    Hummelshøj, Thomas Strabo; Christiansen, Thomas; Somers, Marcel A. J.

    2008-01-01

    Abstract. In the present paper various experimental procedures to experimentally determine the concentration dependent diffusion coefficient of carbon in expanded austenite are evaluated. To this end thermogravimetric carburization was simulated for various experimental conditions and the evaluat...... the approximation of the diffusivity. Thermogravimetry was applied to continuously monitor the weight change of thin foils of AISI 316 during carburizing in CO-H2 gas mixtures for one of the simulated experimental procedures....

  9. Simultaneous inversion for the space-dependent diffusion coefficient and the fractional order in the time-fractional diffusion equation

    International Nuclear Information System (INIS)

    Li, Gongsheng; Zhang, Dali; Jia, Xianzheng; Yamamoto, Masahiro

    2013-01-01

    This paper deals with an inverse problem of simultaneously identifying the space-dependent diffusion coefficient and the fractional order in the 1D time-fractional diffusion equation with smooth initial functions by using boundary measurements. The uniqueness results for the inverse problem are proved on the basis of the inverse eigenvalue problem, and the Lipschitz continuity of the solution operator is established. A modified optimal perturbation algorithm with a regularization parameter chosen by a sigmoid-type function is put forward for the discretization of the minimization problem. Numerical inversions are performed for the diffusion coefficient taking on different functional forms and the additional data having random noise. Several factors which have important influences on the realization of the algorithm are discussed, including the approximate space of the diffusion coefficient, the regularization parameter and the initial iteration. The inversion solutions are good approximations to the exact solutions with stability and adaptivity demonstrating that the optimal perturbation algorithm with the sigmoid-type regularization parameter is efficient for the simultaneous inversion. (paper)

  10. The use of photon correlation spectroscopy method for determining diffusion coefficient in brine and herring flesh

    Directory of Open Access Journals (Sweden)

    Shumanova M.V.

    2015-03-01

    Full Text Available The process fish salting has been studied by the method of photon correlation spectroscopy; the distribution of salt concentration in the solution and herring flesh with skin has been found, diffusion coefficients and salt concentrations used for creating a mathematical model of the salting technology have been worked out; the possibility of determination by this method the coefficient of dynamic viscosity of solutions and different media (minced meat etc. has been considered

  11. Negative Correlation between the Diffusion Coefficient and Transcriptional Activity of the Glucocorticoid Receptor.

    Science.gov (United States)

    Mikuni, Shintaro; Yamamoto, Johtaro; Horio, Takashi; Kinjo, Masataka

    2017-08-25

    The glucocorticoid receptor (GR) is a transcription factor, which interacts with DNA and other cofactors to regulate gene transcription. Binding to other partners in the cell nucleus alters the diffusion properties of GR. Raster image correlation spectroscopy (RICS) was applied to quantitatively characterize the diffusion properties of EGFP labeled human GR (EGFP-hGR) and its mutants in the cell nucleus. RICS is an image correlation technique that evaluates the spatial distribution of the diffusion coefficient as a diffusion map. Interestingly, we observed that the averaged diffusion coefficient of EGFP-hGR strongly and negatively correlated with its transcriptional activities in comparison to that of EGFP-hGR wild type and mutants with various transcriptional activities. This result suggests that the decreasing of the diffusion coefficient of hGR was reflected in the high-affinity binding to DNA. Moreover, the hyper-phosphorylation of hGR can enhance the transcriptional activity by reduction of the interaction between the hGR and the nuclear corepressors.

  12. An innovative method for determining the diffusion coefficient of product nuclide

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Chih Lung [Dept. of Nuclear Back-end Management, Taiwan Power Company, Taipei (China); Wang, Tsing Hai [Dept. Biomedical Engineering and Environment Sciences, National Tsing Hua University, Hsinchu (China)

    2017-08-15

    Diffusion is a crucial mechanism that regulates the migration of radioactive nuclides. In this study, an innovative numerical method was developed to simultaneously calculate the diffusion coefficient of both parent and, afterward, series daughter nuclides in a sequentially reactive through-diffusion model. Two constructed scenarios, a serial reaction (RN{sub 1} → RN{sub 2} → RN{sub 3}) and a parallel reaction (RN{sub 1} → RN{sub 2}A + RN{sub 2}B), were proposed and calculated for verification. First, the accuracy of the proposed three-member reaction equations was validated using several default numerical experiments. Second, by applying the validated numerical experimental concentration variation data, the as-determined diffusion coefficient of the product nuclide was observed to be identical to the default data. The results demonstrate the validity of the proposed method. The significance of the proposed numerical method will be particularly powerful in determining the diffusion coefficients of systems with extremely thin specimens, long periods of diffusion time, and parent nuclides with fast decay constants.

  13. Evaluation of Diffusion Coefficient in a Dextrin-Based Photo-Curable Material by Single Molecule Tracking

    Science.gov (United States)

    Ito, Syoji; Itoh, Kou; Pramanik, Smritimoy; Kusumi, Takatsugu; Takei, Satoshi; Miyasaka, Hiroshi

    2009-07-01

    The translational diffusion coefficient of a perylenediimide (PDI) derivative in a dextrin-based photo-curable material was evaluated by single molecule tracking. Irradiation by UV light for 1.0 s led to a sudden decrease in the diffusion coefficients of ca. 70% of dye molecules, while that of the remaining 30% diffused as fast as in the uncured sample. The number of fast diffusing molecules decreased with increasing UV irradiation time. The diffusion coefficient decreased due to photoinduced network formation and reached a steady value after UV irradiation >8.0 s. This slow diffusion did not cease even after UV irradiation for 32 s.

  14. Role of magnetic resonance diffusion imaging and apparent diffusion coefficient values in the evaluation of spinal tuberculosis in Indian patients

    International Nuclear Information System (INIS)

    Palle, Lalitha; Reddy, MCH Balaji; Reddy, K Jagannath

    2010-01-01

    To define a range of apparent diffusion coefficient values in spinal tuberculosis and to evaluate the sensitivity of diffusion-weighted magnetic resonance imaging (DW-MRI) and apparent diffusion coefficient values in patients of spinal tuberculosis. This study was conducted over a period of 20 months and included 110 patients with a total of 230 vertebral bodies. The study was performed in two parts. The first part included all patients of known tuberculosis and patients with classical features of tuberculosis. The second part included patients with spinal pathology of indeterminate etiology. All the patients underwent a routine MRI examination along with diffusion sequences. The apparent diffusion coefficient (ADC) values were calculated from all the involved vertebral bodies. The mean ADC value of affected vertebrae in first part of the study was found to be 1.4 ± 0.20 × 10 −3 mm 2 /s. This ADC value was then applied to patients in the second part of study in order to determine its ability in predicting tuberculosis. This range of ADC values was significantly different from the mean ADC values of normal vertebrae and those with metastatic involvement. However, there was an overlap of ADC values in a few tuberculous vertebrae with the ADC values in metastatic vertebrae. We found that DW-MRI and ADC values may help in the differentiation of spinal tuberculosis from other lesions of similar appearance. However, an overlap of ADC values was noted with those of metastatic vertebrae. Therefore diffusion imaging and ADC values must always be interpreted in association with clinical history and routine MRI findings and not in isolation

  15. Computation of diffusion coefficients for waters of Gauthami Godavari estuary using one-dimensional advection-diffusion model

    Digital Repository Service at National Institute of Oceanography (India)

    Jyothi, D; Murty, T.V.R.; Sarma, V.V.; Rao, D

    of Marine Sciences Vol. 29, June 2000, pp. 185-187 Short Communication Computation of diffusion coefficients for waters of Gauthami Godavari estuary using one-dimensional advection-diffusion model D Jyothi, T V Ramana Murty, V V Sarma & D P Rao National... and April '96. Salinity was estimated using Kundsen's titration method 1 with an accuracy of ? O.OlxlO"3. Depth at the stations was measured using a portable echo sounder. The average depth along the 32 km stretch varied from 12 m at the mouth to 2 m...

  16. Measurements of the Fe3+ diffusion coefficient in Fricke Xylenol gel using optical density measurements

    International Nuclear Information System (INIS)

    Nonato de Oliveira, Lucas; Sampaio, Francisco Glaildo Almeida; Moreira, Marcos Vasques; Almeida, Adelaide de

    2014-01-01

    In Fricke dosimetry, optical density measurements are performed some time after dosimeter irradiation. Values of the diffusion coefficient of Fe 3+ in Fricke Xylenol gel (FXG) are necessary for determining the spatial distribution of the absorbed dose from measurements of the optical density. Five sets of FXG dosimeters, kept at different constant temperatures, were exposed to collimated 6 MV photons. The optical density profile, proportional to the Fe 3+ concentration, at the boundary between irradiated and non-irradiated parts of each dosimeter was measured periodically over a period of 60 h. By comparing the experimental data with a function that accounts for the unobserved initial concentration profile of Fe 3+ in the FXG, we obtained diffusion coefficients 0.30±0.05, 0.40±0.05, 0.50±0.05, 0.60±0.05 and 0.80±0.05 mm 2 /h for the temperatures 283.0±0.5, 286.0±0.5, 289.0±0.5, 292.0±0.5, and 296.0±0.5 K, respectively. The activation energy of Fe 3+ diffusion in the gel, 0.54±0.06 eV, was determined from the temperature dependence of the diffusion coefficients. - Highlights: • A new analytical method to determine diffusion coefficients of ions in gels is proposed. • The method is applied for measurements of the diffusion coefficients of Fe 3+ ions in a Fricke gel dosimeter. • Activation energy of the Fe 3+ ions in the gel was found to be 0.54 ±0.06 eV

  17. Measurement and modeling of CO2 diffusion coefficient in Saline Aquifer at reservoir conditions

    Science.gov (United States)

    Azin, Reza; Mahmoudy, Mohamad; Raad, Seyed; Osfouri, Shahriar

    2013-12-01

    Storage of CO2 in deep saline aquifers is a promising techniques to mitigate global warming and reduce greenhouse gases (GHG). Correct measurement of diffusivity is essential for predicting rate of transfer and cumulative amount of trapped gas. Little information is available on diffusion of GHG in saline aquifers. In this study, diffusivity of CO2 into a saline aquifer taken from oil field was measured and modeled. Equilibrium concentration of CO2 at gas-liquid interface was determined using Henry's law. Experimental measurements were reported at temperature and pressure ranges of 32-50°C and 5900-6900 kPa, respectively. Results show that diffusivity of CO2 varies between 3.52-5.98×10-9 m2/s for 5900 kPa and 5.33-6.16×10-9 m2/s for 6900 kPa initial pressure. Also, it was found that both pressure and temperature have a positive impact on the measures of diffusion coefficient. Liquid swelling due to gas dissolution and variations in gas compressibility factor as a result of pressure decay was found negligible. Measured diffusivities were used model the physical model and develop concentration profile of dissolved gas in the liquid phase. Results of this study provide unique measures of CO2 diffusion coefficient in saline aquifer at high pressure and temperature conditions, which can be applied in full-field studies of carbon capture and sequestration projects.

  18. A rotational diffusion coefficient of the 70s ribosome determined by depolarized laser light scattering

    NARCIS (Netherlands)

    Bruining, J.; Fijnaut, H.M.

    We have obtained a rotational diffusion coefficient of the 70S ribosome isolated from Escherichia-coli (MRE-600), from the depolarized light scattering spectrum measured by photon correlation spectroscopy. The intensity correlation function of depolarized scattered light contains contributions due

  19. Diffusion Coefficients in Systems LDPE Plus Cyclohexane and LDPE Plus Benzene

    Czech Academy of Sciences Publication Activity Database

    Randová, A.; Bartovská, L.; Hovorka, Š.; Bartovský, T.; Poloncarzová, Magda; Friess, K.

    -, 068 (2010), s. 1-6 ISSN 1618-7229 R&D Projects: GA ČR GA104/08/0600 Institutional research plan: CEZ:AV0Z40720504 Keywords : swelling * diffusion coefficients * low density polyethylene Subject RIV: CI - Industrial Chemistry, Chemical Engineering Impact factor: 0.574, year: 2010

  20. Moisture diffusion coefficients determination of furan bonded sands and water based foundry coatings

    DEFF Research Database (Denmark)

    Di Muoio, Giovanni Luca; Tiedje, Niels Skat

    2016-01-01

    Moisture content in furan bonded sand and water based coatings can be one of the main causes for gas related defects in large cast iron parts. Moisture diffusion coefficients for these materials are needed to precisely predict the possible moisture levels in foundry moulds. In this study, we first...

  1. Unified derivation of the various definitions of lattice cell diffusion coefficients

    International Nuclear Information System (INIS)

    Hughes, R.P.

    1978-01-01

    The various definitions of lattice cell diffusion coefficients are discussed within the context of a one-dimensional slab lattice in one energy group. It is shown how each definition, although originally derived in its own particular way, can be derived from a single approach. This makes clear the differences between, and the advantages of, the various definitions

  2. Trapped-ion anomalous diffusion coefficient on the basis of single mode saturation

    International Nuclear Information System (INIS)

    Koshi, Yuji; Hatayama, Akiyoshi; Ogasawara, Masatada.

    1982-03-01

    Expressions of the anomalous diffusion coefficient due to the dissipative trapped ion instability (DTII) are derived for the case with and without the effect of magnetic shear. Derivation is made by taking into account of the single mode saturation of the DTII previously obtained numerically. In the absence of the shear effect, the diffusion coefficient is proportional to #betta#sub(i)a 2 (#betta#sub(i) is the effective collision frequency of the trapped ions and a is the minor radius of a torus) and is much larger than the neoclassical ion heat conductivity. In the presence of the shear effect, the diffusion coefficient is much smaller than the Kadomtsev and Pogutse's value and is the same order of magnitude as the neoclassical ion heat conductivity. Dependences of the diffusion coefficient on the temperature and on the total particle number density are rather complicated due to the additional spectral cut-off, which is introduced to regularize the short wavelength modes in the numerical analysis. (author)

  3. Calculation of calcium diffusion coefficient of cement hardenings using minute pore data

    International Nuclear Information System (INIS)

    Hitomi, Takashi; Takeda, Nobufumi; Iriya, Keishiro

    2009-01-01

    This report describes the calculations of the diffusion coefficient of the Ca ion of cement hardenings using minute pore data. The observed hardenings were ordinary Portland cement (OPC), low-heat Portland cement with fly ash (LPC+FA) and highly fly ash containing silica fume cement (HFSC). The samples were cured in the standard and artificially leached by accelerated test. Minute pore datas of the cement hardenings were acquired with image processing of internal structural information obtained from high resolution X-ray computed tomography observations. Upon analysis, several voxels are combined into one bigger voxel, the diffusion coefficient of the voxels were determined in proportion to the number of voxels which were included in. The results reveal that the change in the calcium diffusion coefficient of OPC due to leaching was large, but the LPC+FA and HFSC cements exhibited even greater changes than OPC. It is suggested that the diffusion coefficients are proportional to the Ca/Si ratio of the samples. (author)

  4. Novel Technique for Direct Measurement of the Plasma Diffusion Coefficient in Magnetized Plasma

    Czech Academy of Sciences Publication Activity Database

    Brotánková, Jana; Martines, E.; Adámek, Jiří; Stöckel, Jan; Popa, G.; Costin, C.; Ionita, G.; Schrittwieser, R.; Van Oost, G.

    2008-01-01

    Roč. 48, 5-7 (2008), s. 418-423 ISSN 0863-1042. [International Workshop on Electrical Probes in Magnetized Plasmas/7th./. Praha, 22.07.2007-25.07.2007] Institutional research plan: CEZ:AV0Z20430508 Keywords : Tokamak * probe diagnostics * diffusion coefficient Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 1.250, year: 2008

  5. Diffusion coefficient and solubility of isobutene and trans-2-butene in aqueous sulfuric acid solutions

    NARCIS (Netherlands)

    Brilman, Derk Willem Frederik; van Swaaij, Willibrordus Petrus Maria; Versteeg, Geert

    2001-01-01

    The diffusion coefficient and the physical solubility of isobutene and trans-2-butene in aqueous sulfuric acid solutions cannot be determined experimentally due to the occurrence of fast chemical reactions. In the present contribution these physicochemical parameters are estimated. For the

  6. Diffusion Coefficient and Solubility of Isobutene and trans-2-Butene in Aqueous Sulfuric Acid Solutions

    NARCIS (Netherlands)

    Brilman, Derk W.F.; Swaaij, Wim P.M. van; Versteeg, Geert F.

    2001-01-01

    The diffusion coefficient and the physical solubility of isobutene and trans-2-butene in aqueous sulfuric acid solutions cannot be determined experimentally due to the occurrence of fast chemical reactions. In the present contribution these physicochemical parameters are estimated. For the

  7. Accurate determination of the diffusion coefficient of proteins by Fourier analysis with whole column imaging detection.

    Science.gov (United States)

    Zarabadi, Atefeh S; Pawliszyn, Janusz

    2015-02-17

    Analysis in the frequency domain is considered a powerful tool to elicit precise information from spectroscopic signals. In this study, the Fourier transformation technique is employed to determine the diffusion coefficient (D) of a number of proteins in the frequency domain. Analytical approaches are investigated for determination of D from both experimental and data treatment viewpoints. The diffusion process is modeled to calculate diffusion coefficients based on the Fourier transformation solution to Fick's law equation, and its results are compared to time domain results. The simulations characterize optimum spatial and temporal conditions and demonstrate the noise tolerance of the method. The proposed model is validated by its application for the electropherograms from the diffusion path of a set of proteins. Real-time dynamic scanning is conducted to monitor dispersion by employing whole column imaging detection technology in combination with capillary isoelectric focusing (CIEF) and the imaging plug flow (iPF) experiment. These experimental techniques provide different peak shapes, which are utilized to demonstrate the Fourier transformation ability in extracting diffusion coefficients out of irregular shape signals. Experimental results confirmed that the Fourier transformation procedure substantially enhanced the accuracy of the determined values compared to those obtained in the time domain.

  8. Calculation of the mutual diffusion coefficient by equilibrium and nonequilibrium molecular dynamics

    International Nuclear Information System (INIS)

    Erpenbeck, J.J.; Kincaid, J.M.

    1985-01-01

    A nonequilibrium molecular dynamics method for the calculation of the mutual diffusion coefficient for a mixture of hard spheres is described. The method is applied to a 50-50 mixture of equidiameter particles having a mass ratio of 0.1 for the two species, at a volume of three times close-packing. By extrapolating the results to the limit of vanishing concentration gradient and infinite system size, we obtain a value in statistical agreement with the result obtained using a Green-Kubo molecular dynamics procedure which is also described. The nonequilibrium calculation yields a mutual diffusion coefficient which decreases slightly with increasing concentration gradient. The Green-Kubo time correlation function for mutual diffusion displays a slow decay with time, qualitatively similar to the long-time tail which has been predicted by the hydrodynamic theory of Pomeau

  9. Mass diffusion coefficient measurement for vitreous humor using FEM and MRI

    Science.gov (United States)

    Rattanakijsuntorn, Komsan; Penkova, Anita; Sadha, Satwindar S.

    2018-01-01

    In early studies, the ‘contour method’ for determining the diffusion coefficient of the vitreous humor was developed. This technique relied on careful injection of an MRI contrast agent (surrogate drug) into the vitreous humor of fresh bovine eyes, and tracking the contours of the contrast agent in time. In addition, an analytical solution was developed for the theoretical contours built on point source model for the injected surrogate drug. The match between theoretical and experimental contours as a least square fit, while floating the diffusion coefficient, led to the value of the diffusion coefficient. This method had its limitation that the initial injection of the surrogate had to be spherical or ellipsoidal because of the analytical result based on the point-source model. With a new finite element model for the analysis in this study, the technique is much less restrictive and handles irregular shapes of the initial bolus. The fresh bovine eyes were used for drug diffusion study in the vitreous and three contrast agents of different molecular masses: gadolinium-diethylenetriaminepentaacetic acid (Gd-DTPA, 938 Da), non-ionic gadoteridol (Prohance, 559 Da), and bovine albumin conjugated with gadolinium (Galbumin, 74 kDa) were used as drug surrogates to visualize the diffusion process by MRI. The 3D finite element model was developed to determine the diffusion coefficients of these surrogates with the images from MRI. This method can be used for other types of bioporous media provided the concentration profile can be visualized (by methods such as MRI or fluorescence).

  10. An elemental mercury diffusion coefficient for natural waters determined by molecular dynamics simulation.

    Science.gov (United States)

    Kuss, Joachim; Holzmann, Jörg; Ludwig, Ralf

    2009-05-01

    Mercury is a priority pollutant as its mobility between the hydrosphere and the atmosphere threatens the biosphere globally. The air-water gas transfer of elemental mercury (Hg0) is controlled by its diffusion through the water-side boundary layer and thus by its diffusion coefficient, D(Hg), the value of which, however, has not been established. Here, the diffusion of Hg0 in water was modeled by molecular dynamics (MD) simulation and the diffusion coefficient subsequently determined. Therefore the movement of either Hg(0) or xenon and 1000 model water molecules (TIP4P-Ew) were traced for time spans of 50 ns. The modeled D(Xe) of the monatomic noble gas agreed well with measured data; thus, MD simulation was assumed to be a reliable approach to determine D(Hg) for monatomic Hg(0) as well. Accordingly, Hg(0) diffusion was then simulated for freshwater and seawater, and the data were well-described by the equation of Eyring. The activation energies for the diffusion of Hg0 in freshwater was 17.0 kJ mol(-1) and in seawater 17.8 kJ mol(-1). The newly determined D(Hg) is clearly lower than the one previously used for an oceanic mercury budget. Thus, its incorporation into the model should lead to lower estimates of global ocean mercury emissions.

  11. Evaluation of Systematic and Random Error in the Measurement of Equilibrium Solubility and Diffusion Coefficient for Liquids in Polymers

    National Research Council Canada - National Science Library

    Shuely, Wendel

    2001-01-01

    A standardized thermogravimetric analyzer (TGA) desorption method for measuring the equilibrium solubility and diffusion coefficient of toxic contaminants with polymers was further developed and evaluated...

  12. Analysis and correction of gradient nonlinearity bias in apparent diffusion coefficient measurements.

    Science.gov (United States)

    Malyarenko, Dariya I; Ross, Brian D; Chenevert, Thomas L

    2014-03-01

    Gradient nonlinearity of MRI systems leads to spatially dependent b-values and consequently high non-uniformity errors (10-20%) in apparent diffusion coefficient (ADC) measurements over clinically relevant field-of-views. This work seeks practical correction procedure that effectively reduces observed ADC bias for media of arbitrary anisotropy in the fewest measurements. All-inclusive bias analysis considers spatial and time-domain cross-terms for diffusion and imaging gradients. The proposed correction is based on rotation of the gradient nonlinearity tensor into the diffusion gradient frame where spatial bias of b-matrix can be approximated by its Euclidean norm. Correction efficiency of the proposed procedure is numerically evaluated for a range of model diffusion tensor anisotropies and orientations. Spatial dependence of nonlinearity correction terms accounts for the bulk (75-95%) of ADC bias for FA = 0.3-0.9. Residual ADC non-uniformity errors are amplified for anisotropic diffusion. This approximation obviates need for full diffusion tensor measurement and diagonalization to derive a corrected ADC. Practical scenarios are outlined for implementation of the correction on clinical MRI systems. The proposed simplified correction algorithm appears sufficient to control ADC non-uniformity errors in clinical studies using three orthogonal diffusion measurements. The most efficient reduction of ADC bias for anisotropic medium is achieved with non-lab-based diffusion gradients. Copyright © 2013 Wiley Periodicals, Inc.

  13. Theory of the diffusion coefficient of neutrons in a lattice containing cavities; Theorie du coefficient de diffusion des neutrons dans un reseau comportant des cavites

    Energy Technology Data Exchange (ETDEWEB)

    Benoist, P. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-01-15

    In an previous publication, a simple and general formulation of the diffusion coefficient, which defines the mode of weighting of the mean free paths of the various media, in introducing the collision probabilities in each medium, was established. This expression is demonstrated again here through a more direct method, and the velocity is introduced; new terms are emphasised, the existence of which implies that the representation of the diffusion area as the mean square of the straight line distance from source to absorption is not correct in a lattice. However these terms are of small enough an order of magnitude to he treated as a correction. The general expression also shows the existence, for the radial coefficient, of the series of angular correlation terms, which is seen to converge very slowly for large channels. The term by term computation which was initiated in the first work was then interrupted and a global formulation, which emphasize a resemblance with the problem of the thermal utilisation factor, was adopted. An integral method, analogous to that use for the computation of this factor, gives the possibility to establish new and simple practical formulae, which require the use of a few basic functions only. These formulae are very accurate, as seen from the results of a variational method which was studied as a reference. Various correction effects are reviewed. Expressions which allow the exact treatment of fuel rod clusters are presented. The theory is confronted with various experimental results, and a new method of measuring the radial coefficient is proposed. (author) [French] Dans une publication anterieure, on a etablie une formulation simple et generale du coefficient de diffusion, qui definit le mode de ponderation des libres parcours des differents milieux constituants en faisant apparaitre les probabilites de collision dans chaque milieu. On redemontre ici cette expression d'une maniere plus directe, tout en introduisant la variable

  14. Apparent diffusion coefficient mapping of infarcted tissue and the ischaemic penumbra in acute stroke

    International Nuclear Information System (INIS)

    El-Koussy, M.; Loevblad, K.O.; Kiefer, C.; Zeller, O.; Buerki, M.; Oswald, H.; Schroth, G.; Arnold, M.; Wels, T.

    2002-01-01

    MRI assessment of diffusion changes in acute cerebral ischaemia necessitates analysis of the apparent diffusion coefficient (ADC). We used the concept of relative weighted mean ADC (rwmADC) to obtain an accurate estimate of the extent of infarcted tissue. We studied ten patient with of acute ischaemic stroke, using diffusion- and perfusion- weighted MRI. The rwmADC was used to calculate a corrected ADC-lesion volume (DLVR), which was compared with the diffusion-lesion volume (DLV), initial perfusion lesion volumes and the follow-up infarct volume on T2-weighted images. We looked at correlations between the MRI and clinical findings. DLVR was closest to the final infarct size and had the best clinicoradiological correlation (r=0.77). Weighting the mean ADC within the ischaemic and normal parenchyma can give a more correct estimate of the volume of infarcted brain parenchyma, thus improving the definition of the penumbra. (orig.)

  15. Diffusion-controlled reaction. V. Effect of concentration-dependent diffusion coefficient on reaction rate in graft polymerization

    International Nuclear Information System (INIS)

    Imre, K.; Odian, G.

    1979-01-01

    The effect of diffusion on radiation-initiated graft polymerization has been studied with emphasis on the single- and two-penetrant cases. When the physical properties of the penetrants are similar, the two-penetrant problems can be reduced to the single-penetrant problem by redefining the characteristic parameters of the system. The diffusion-free graft polymerization rate is assumed to be proportional to the upsilon power of the monomer concentration respectively, and, in which the proportionality constant a = k/sub p/R/sub i//sup w//k/sub t//sup z/, where k/sub p/ and k/sub t/ are the propagation and termination rate constants, respectively, and R/sub i/ is the initiation rate. The values of upsilon, w, and z depend on the particular reaction system. The results of earlier work were generalized by allowing a non-Fickian diffusion rate which predicts an essentially exponential dependence on the monomer concentration of the diffusion coefficient, D = D 0 [exp(deltaC/M)], where M is the saturation concentration. A reaction system is characterized by the three dimensionless parameters, upsilon, delta, and A = (L/2)[aM/sup (upsilon--1)//D 0 ]/sup 1/2/, where L is the polymer film thickness. Graft polymerization tends to become diffusion controlled as A increases. Larger values of delta and ν cause a reaction system to behave closer to the diffusion-free regime. Transition from diffusion-free to diffusion-controlled reaction involves changes in the dependence of the reaction rate on film thickness, initiation rate, and monomer concentration. Although the diffusion-free rate is w order in initiation rate, upsilon order in monomer, and independent of film thickness, the diffusion-controlled rate is w/2 order in initiator rate and inverse first-order in film thickness. Dependence of the diffusion-controlled rate on monomer is dependent in a complex manner on the diffusional characteristics of the reaction system. 11 figures, 4 tables

  16. Dependence of growth of the phases of multiphase binary systems on the diffusion parameters

    Science.gov (United States)

    Molokhina, L. A.; Rogalin, V. E.; Filin, S. A.; Kaplunov, I. A.

    2017-12-01

    A mathematical model of the diffusion interaction of a binary system with several phases on the equilibrium phase diagram is presented. The theoretical and calculated dependences of the layer thickness of each phase in the multiphase diffusion zone on the isothermal annealing time and the ratio of the diffusion parameters in the neighboring phases with an unlimited supply of both components were constructed. The phase formation and growth in the diffusion zone during "reactive" diffusion corresponds to the equilibrium state diagram for two components, and the order of their appearance in the diffusion zone depends only on the ratio of the diffusion parameters in the phases themselves and on the duration of the incubation periods. The dependence of phase appearance on the incubation periods, annealing time, and difference in the movement rates of the components across the interface boundaries was obtained. An example of the application of the model for processing the experimental data on phase growth in a two-component three-phase system was given.

  17. Determining diffusion coefficients of ionic liquids by means of field cycling nuclear magnetic resonance relaxometry

    Energy Technology Data Exchange (ETDEWEB)

    Kruk, D. [Faculty of Mathematics and Computer Science, University of Warmia and Mazury in Olsztyn, Słoneczna 54, PL-10710 Olsztyn (Poland); Universität Bayreuth, Experimentalphysik II, 95440 Bayreuth (Germany); Meier, R.; Rössler, E. A. [Universität Bayreuth, Experimentalphysik II, 95440 Bayreuth (Germany); Rachocki, A. [Institute of Molecular Physics, Polish Academy of Sciences, Smoluchowskiego 17, 60-179 Poznań (Poland); Korpała, A. [Department of Biophysics, Jagiellonian University Medical College, Łazarza 16, 31-530 Kraków, Poland and Institute of Physics, Jagiellonian University, Reymonta 4, 30-059 Kraków (Poland); Singh, R. K. [Ionic Liquid and Solid State Ionics Laboratory, Department of Physics, Banaras Hindu University, Varanasi 221 005 (India)

    2014-06-28

    Field Cycling Nuclear Magnetic Resonance (FC NMR) relaxation studies are reported for three ionic liquids: 1-ethyl-3- methylimidazolium thiocyanate (EMIM-SCN, 220–258 K), 1-butyl-3-methylimidazolium tetrafluoroborate (BMIM-BF{sub 4}, 243–318 K), and 1-butyl-3-methylimidazolium hexafluorophosphate (BMIM-PF{sub 6}, 258–323 K). The dispersion of {sup 1}H spin-lattice relaxation rate R{sub 1}(ω) is measured in the frequency range of 10 kHz–20 MHz, and the studies are complemented by {sup 19}F spin-lattice relaxation measurements on BMIM-PF{sub 6} in the corresponding frequency range. From the {sup 1}H relaxation results self-diffusion coefficients for the cation in EMIM-SCN, BMIM-BF{sub 4}, and BMIM-PF{sub 6} are determined. This is done by performing an analysis considering all relevant intra- and intermolecular relaxation contributions to the {sup 1}H spin-lattice relaxation as well as by benefiting from the universal low-frequency dispersion law characteristic of Fickian diffusion which yields, at low frequencies, a linear dependence of R{sub 1} on square root of frequency. From the {sup 19}F relaxation both anion and cation diffusion coefficients are determined for BMIM-PF{sub 6}. The diffusion coefficients obtained from FC NMR relaxometry are in good agreement with results reported from pulsed- field-gradient NMR. This shows that NMR relaxometry can be considered as an alternative route of determining diffusion coefficients of both cations and anions in ionic liquids.

  18. Investigation of diffusivity coefficient of Asmari reservoir by well test analysis

    Energy Technology Data Exchange (ETDEWEB)

    Shadizadeh, S.R. [Petroleum Univ. of Technology, Tehran (Iran, Islamic Republic of); Amiri, M.; Zaferanieh, M. [National Iranian Oil Co., Tehran (Iran, Islamic Republic of)

    2007-07-01

    One of the greatest challenges facing petroleum engineers is to characterize the physical nature of subterranean reservoirs from which crude oil is produced. The quality of reservoir description determines the results of numerical simulations of reservoir performance. The ways by which information can be obtained include seismic and geological studies; well drilling data; well pressure testing; and analysis of reservoir performance through history matching. This paper presented the results of a study in which the Asmari field in southern onshore Iran was characterized. The field went into production in 1970. To date, a total of 39 wells have been completed in the Asmari and Bangestan groups of this field. Pan System software was used in this study to analyze the well test data. Parameters such as permeability, skin factor, wellbore storage, average reservoir pressure, diffusivity coefficient and productivity index are calculated for each well. In particular, the diffusivity coefficient for the Asmari sedimentary layer was determined. This dimensionless reservoir parameter is a ratio of a medium's capacity for transmissibility of fluid to capacity. Diffusivity offers a quantitative measure for the rate of response during transient fluid flow. All available information such as petrophysical data, PVT data, production data and pressure build up data of the completed wells in Asmari formation were collected. Twenty one data tests were then analyzed. A correlation between productivity index and the diffusivity coefficient for the Asmari formation was subsequently obtained. It was concluded that permeability is one of the most important parameter in reservoir engineering calculations. Different completion of well number 1 showed that the diffusivity coefficient and productivity index of carbonate layer is less than in the sandstone layer. It was determined that the western part of the reservoir is suitable for drilling new wells.13 refs., 5 tabs., 7 figs.

  19. Evaluation of downwelling diffuse attenuation coefficient algorithms in the Red Sea

    KAUST Repository

    Tiwari, Surya Prakash

    2016-05-07

    Despite the importance of the optical properties such as the downwelling diffuse attenuation coefficient for characterizing the upper water column, until recently no in situ optical measurements were published for the Red Sea. Kirby et al. used observations from the Coastal Zone Color Scanner to characterize the spatial and temporal variability of the diffuse attenuation coefficient (Kd(490)) in the Red Sea. To better understand optical variability and its utility in the Red Sea, it is imperative to comprehend the diffuse attenuation coefficient and its relationship with in situ properties. Two apparent optical properties, spectral remote sensing reflectance (Rrs) and the downwelling diffuse attenuation coefficient (Kd), are calculated from vertical profile measurements of downwelling irradiance (Ed) and upwelling radiance (Lu). Kd characterizes light penetration into water column that is important for understanding both the physical and biogeochemical environment, including water quality and the health of ocean environment. Our study tests the performance of the existing Kd(490) algorithms in the Red Sea and compares them against direct in situ measurements within various subdivisions of the Red Sea. Most standard algorithms either overestimated or underestimated with the measured in situ values of Kd. Consequently, these algorithms provided poor retrieval of Kd(490) for the Red Sea. Random errors were high for all algorithms and the correlation coefficients (r2) with in situ measurements were quite low. Hence, these algorithms may not be suitable for the Red Sea. Overall, statistical analyses of the various algorithms indicated that the existing algorithms are inadequate for the Red Sea. The present study suggests that reparameterizing existing algorithms or developing new regional algorithms is required to improve retrieval of Kd(490) for the Red Sea. © (2016) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is

  20. New Hydrogen Self Diffusion Coefficients in Olivine Using NanoSIMS

    Science.gov (United States)

    Du Frane, W. L.; Novella, D.; Jacobsen, B.; Weber, P. K.; Ryerson, F. J.; Tyburczy, J. A.

    2015-12-01

    We have previously reported hydrogen self-diffusion coefficients for olivine in deuterium-hydrogen exchange experiments, but were only able to resolve diffusion profiles reliably in the 'fast' [100] orientation due to the limited spatial resolution of the Cameca 6f Secondary Ion Mass Spectrometry (SIMS) instrument. Samples were reanalyzed using the Cameca nanoSIMS, which enabled simultaneous measurements of diffusion coefficients in the 'fast' [100] orientation and the additional 'slow' [010] and [001] orientations to gain a complete 3D view of hydrogen self-diffusion. Measurement precision of deuterium (16O2H with a Cs+beam) is also improved by higher vacuum, better environmental control, and lower background. Deuterium-hydrogen exchange experiments were conducted at 2 GPa between 750-900 °C by first saturating olivine with homogenous distribution of hydrogen (1H) and then exchanging some of this with deuterium (2H) in a subsequent experiment. The diffusion coefficents in the [100] orientation that were measured using the nanoSIMS are in good agreement with the previous measurements on the 6f. Diffusion coefficients in the [010] and [001] orientations are very similar in magnitude to one another, ranging between 10-13 to 10-14 m2/s, which is over an order of magnitude lower than the [100] orientation. Hydrogen self-diffusion is highly anisotropic in this temperature range, although the activation enthalpies for diffusion in the [010] and [001] orientations are significantly higher than that of the [100] orientation, such that there will be less anisotropy at higher temperatures relevant to the upper mantle. Comparisons between chemical and self-diffusion measurements allow us to evaluate the various stoichiometric relationships that have been proposed for accommodating hydrogen into the nominally anhydrous structure of olivine. Based on these relationships, we estimate diffusivities of other point defects, small polarons and metal vacancies, as a function of

  1. Estimation of the eddy diffusivity coefficient in a warm monomictic tropical Lake

    Directory of Open Access Journals (Sweden)

    David A. Salas de León

    2016-03-01

    Full Text Available We used a two-year dataset (1998-1999 of monthly temperature profiles from Lake Alchichica, Mexico to estimate values of the vertical coefficient of eddy diffusivity. This lake is located in a tropical region at high altitude and shows considerable seasonal variations (i.e., rainy and dry seasons. It has an area of 2.3 km2 and a mean depth of 40.9 m. Alchichica is a warm monomictic lake, which annually becomes isothermal near the end of December or early January at the onset of the dry season and remains stratified for the rest of the year (from late March or early April to early December during the warm-rainy season. Mathematical models of the spatial and temporal variation of passive substances in lakes and oceans require a quantitative formulation of the vertical transport. Vertical mixing is generally a function of the density profile, which, in lakes, can be directly related to the temperature profile. A widely used method to estimate the vertical diffusion coefficients in lakes from temperature data is the flux-gradient method. In the present study, we applied a simple approach to calculate the eddy diffusivity coefficient (Kz based on the solution of the vertical component of the modeled temperature equation. We characterized the eddy diffusivity coefficient (Kz in Lake Alchichica as a dynamic coefficient that changes during the year, between years, and with depth, ranging from 10-10 to 10-6 m2 s-1, whereas typical values of Kz in thermally stratified lakes range from 10-9 to 10-2 m2 s-1. As expected, we found the lowest values in the deeper regions of the lake, and that the temporal variation of temperature with depth showed a quasi-bimodal shape from one year to the next. We also found a structure of alternating peaks and troughs in the vertical Kz, which indicates a response to oscillating vertical mixing. We concluded that the solution of the vertical component of the temperature equation could be a useful tool to estimate the eddy

  2. Correlation of human papillomavirus status with apparent diffusion coefficient of diffusion-weighted MRI in head and neck squamous cell carcinomas.

    Science.gov (United States)

    Driessen, Juliette P; van Bemmel, Alexander J M; van Kempen, Pauline M W; Janssen, Luuk M; Terhaard, Chris H J; Pameijer, Frank A; Willems, Stefan M; Stegeman, Inge; Grolman, Wilko; Philippens, Marielle E P

    2016-04-01

    Identification of prognostic patient characteristics in head and neck squamous cell carcinoma (HNSCC) is of great importance. Human papillomavirus (HPV)-positive HNSCCs have favorable response to (chemo)radiotherapy. Apparent diffusion coefficient, derived from diffusion-weighted MRI, has also shown to predict treatment response. The purpose of this study was to evaluate the correlation between HPV status and apparent diffusion coefficient. Seventy-three patients with histologically proven HNSCC were retrospectively analyzed. Mean pretreatment apparent diffusion coefficient was calculated by delineation of total tumor volume on diffusion-weighted MRI. HPV status was analyzed and correlated to apparent diffusion coefficient. Six HNSCCs were HPV-positive. HPV-positive HNSCC showed significantly lower apparent diffusion coefficient compared to HPV-negative. This correlation was independent of other patient characteristics. In HNSCC, positive HPV status correlates with low mean apparent diffusion coefficient. The favorable prognostic value of low pretreatment apparent diffusion coefficient might be partially attributed to patients with a positive HPV status. © 2015 Wiley Periodicals, Inc. Head Neck 38: E613-E618, 2016. © 2015 Wiley Periodicals, Inc.

  3. Reperfusion demonstrated by apparent diffusion coefficient mapping after local intra-arterial thrombolysis for ischaemic stroke

    International Nuclear Information System (INIS)

    Taleb, M.; Loevblad, K.O.; El-Koussy, M.; Guzman, R.; Oswald, H.; Remonda, L.; Schroth, G.; Bassetti, C.; Arnold, M.

    2001-01-01

    Diffusion-weighted MRI (DWI) is becoming important for diagnosis and investigation of acute cerebral ischaemia. It has been reported that apparent diffusion coefficient (ADC) maps could be an indicator of reperfusion. Our aim was to use echo-planar technology to investigate this phenomenon. We report 19 patients treated by local intra-arterial thrombolysis for middle cerebral artery stroke within 6 h of the onset of symptoms, in whom we performed follow-up DWI. ADC were found to be higher in the patients with angiographically proven reperfusion. (orig.)

  4. Measurement of the absorption coefficient of sound absorbing materials under a synthesized diffuse acoustic field.

    Science.gov (United States)

    Robin, Olivier; Berry, Alain; Doutres, Olivier; Atalla, Noureddine

    2014-07-01

    This letter proposes an experimental method to estimate the absorption coefficient of sound absorbing materials under a synthesized diffuse acoustic field in free-field conditions. Comparisons are made between experiments conducted with this approach, the standard reverberant room method, and numerical simulations using the transfer matrix method. With a simple experimental setup and smaller samples than those required by standards, the results obtained with the proposed approach do not exhibit non-physical trends of the reverberant room method and provide absorption coefficients in good agreement with those obtained by simulations for a laterally infinite material.

  5. Effects of MR parameter changes on the quantification of diffusion anisotropy and apparent diffusion coefficient in diffusion tensor imaging: evaluation using a diffusional anisotropic phantom.

    Science.gov (United States)

    Kim, Sang Joon; Choi, Choong Gon; Kim, Jeong Kon; Yun, Sung-Cheol; Jahng, Geon-Ho; Jeong, Ha-Kyu; Kim, Eun Ju

    2015-01-01

    To validate the usefulness of a diffusional anisotropic capillary array phantom and to investigate the effects of diffusion tensor imaging (DTI) parameter changes on diffusion fractional anisotropy (FA) and apparent diffusion coefficient (ADC) using the phantom. Diffusion tensor imaging of a capillary array phantom was performed with imaging parameter changes, including voxel size, number of sensitivity encoding (SENSE) factor, echo time (TE), number of signal acquisitions, b-value, and number of diffusion gradient directions (NDGD), one-at-a-time in a stepwise-incremental fashion. We repeated the entire series of DTI scans thrice. The coefficients of variation (CoV) were evaluated for FA and ADC, and the correlation between each MR imaging parameter and the corresponding FA and ADC was evaluated using Spearman's correlation analysis. The capillary array phantom CoVs of FA and ADC were 7.1% and 2.4%, respectively. There were significant correlations between FA and SENSE factor, TE, b-value, and NDGD, as well as significant correlations between ADC and SENSE factor, TE, and b-value. A capillary array phantom enables repeated measurements of FA and ADC. Both FA and ADC can vary when certain parameters are changed during diffusion experiments. We suggest that the capillary array phantom can be used for quality control in longitudinal or multicenter clinical studies.

  6. Shear viscosity and spin-diffusion coefficient of a two-dimensional Fermi gas

    DEFF Research Database (Denmark)

    Bruun, Georg

    2012-01-01

    Using kinetic theory, we calculate the shear viscosity and the spin-diffusion coefficient as well as the associated relaxation times for a two-component Fermi gas in two dimensions, as a function of temperature, coupling strength, polarization, and mass ratio of the two components. It is demonstr......Using kinetic theory, we calculate the shear viscosity and the spin-diffusion coefficient as well as the associated relaxation times for a two-component Fermi gas in two dimensions, as a function of temperature, coupling strength, polarization, and mass ratio of the two components....... It is demonstrated that the minimum value of the viscosity decreases with the mass ratio, since Fermi blocking becomes less efficient. We furthermore analyze recent experimental results for the quadrupole mode of a two-dimensional gas in terms of viscous damping, obtaining a qualitative agreement using no fitting...

  7. Determination of the Solute Diffusion Coefficient by the Droplet Migration Method

    Energy Technology Data Exchange (ETDEWEB)

    Shan Liu; Jing Teng; Jeongyun Choi

    2007-07-01

    Further analysis of droplet migration in a temperature gradient field indicates that different terms can be used to evaluate the solute diffusion coefficient in liquid (D{sub L}) and that there exists a characteristic curve that can describe the motion of all the droplets for a given composition and temperature gradient. Critical experiments are subsequently conducted in succinonitrile (SCN)-salol and SCN-camphor transparent alloys in order to observe dynamic migration processes of a number of droplets. The derived diffusion coefficients from different terms are the same within experimental error. For SCN-salol alloys, D{sub L} = (0.69 {+-} 0.05) x 10{sup -3} mm{sup 2}/s, and for SCN-camphor alloys, D{sub L} = (0.24 {+-} 0.02) x 10{sup -3} mm{sup 2}/s.

  8. Determination of the diffusion coefficient of new insulators composed of vegetable fibers

    Directory of Open Access Journals (Sweden)

    Boulaoued I.

    2012-01-01

    Full Text Available The knowledge of the moisture transport of building materials is necessary for the performance of building structures. The control of moisture transport is essential to describe the moisture migration process through the building walls. The present work’s aim is to determine through experiment the water diffusion coefficient of different insulators in unsteady-state based on the Fick’s second law equation. This equation was solved analytically by the separation of variables method (MOD1 and by the change of variables method (MOD2. The moisture diffusion coefficient for building material was experimentally predicted by using the weighing technique and different analytical methods. The results were compared with experimental data.

  9. Diffusion coefficients-surface and interfacial tensions - Particular study of some lauryl compounds

    International Nuclear Information System (INIS)

    Morel, Jean-Emile

    1969-01-01

    Two important results of the double lipophilic and hydrophilic character of some heavy organic compounds with a polar group at the end of the chain, were studied: - In a first part, molecular diffusion coefficients were measured in order to prove the micellar aggregation of tri-laurylammonium nitrate in some organic solutions; - In a second part, the tensioactivity of some lauryl compounds (lauric acid, lauric alcohol, mono-laurylamine, etc.), was studied. (author) [fr

  10. AOPs Are Not Additive: On the Biogeo-Optical Modeling of the Diffuse Attenuation Coefficient

    Directory of Open Access Journals (Sweden)

    Zhongping Lee

    2018-01-01

    Full Text Available Commonly we see the diffuse attenuation coefficient of downwelling irradiance (Kd expressed as a sum of the contributions of various constituents. We show here that, both theoretically and numerically, because Kd is an apparent optical property (AOP, this approach is not consistent with radiative transfer. We further advocate the application of models of Kd developed in past decades that are not only consistent with radiative transfer but also provide more accurate estimates, in particular for coastal turbid waters.

  11. Charge effect on the diffusion coefficient and the bimolecular reaction rate of diiodide anion radical in room temperature ionic liquids.

    Science.gov (United States)

    Nishiyama, Yoshio; Terazima, Masahide; Kimura, Yoshifumi

    2009-04-16

    The diffusion coefficients of diiodide anion radical, I(2)(-), in room temperature ionic liquids (RTILs) were determined by the transient grating (TG) method using the photochemical reaction of iodide. The diffusion coefficients we obtained were larger in RTILs than the theoretical predictions by the Stokes-Einstein relation, whereas both values are similar in conventional solvents. By comparison with the diffusion coefficients of neutral molecules, it was suggested that the Coulomb interaction between I(2)(-) and constituent ions of RTILs strongly affects the diffusion coefficients. The bimolecular reaction rates between I(2)(-) were calculated by the Debye-Smoluchowski equation using the experimentally determined diffusion coefficients. These calculated reaction rate were much smaller than the experimentally determined rates (Takahashi, K.; et al. J. Phys. Chem. B 2007, 111, 4807), indicating the charge screening effect of RTILs.

  12. Trends in Effective Diffusion Coefficients for Ion-Exchange Strengthening of Soda-Lime-Silicate Glasses

    Directory of Open Access Journals (Sweden)

    Stefan Karlsson

    2017-04-01

    Full Text Available Monovalent cations enable efficient ion-exchange processes due to their high mobility in silicate glasses. Numerous properties can be modified in this way, e.g., mechanical, optical, electrical, or chemical performance. In particular, alkali cation exchange has received significant attention, primarily with respect to introducing compressive stress into the surface region of a glass, which increases mechanical durability. However, most of the present applications rely on specifically tailored matrix compositions in which the cation mobility is enhanced. This largely excludes the major area of soda-lime-silicates (SLS such as are commodity in almost all large-scale applications of glasses. Basic understanding of the relations between structural parameters and the effective diffusion coefficients may help to improve ion-exchanged SLS glass products, on the one hand in terms of obtainable strength and on the other in terms of cost. In the present paper, we discuss the trends in the effective diffusion coefficients when exchanging Na+ for various monovalent cations (K+, Cu+, Ag+, Rb+, and Cs+ by drawing relations to physicochemical properties. Correlations of effective diffusion coefficients were found for the bond dissociation energy and the electronic cation polarizability, indicating that localization and rupture of bonds are of importance for the ion-exchange rate.

  13. Comparative analyses of diffusion coefficients for different extraction processes from thyme

    Directory of Open Access Journals (Sweden)

    Petrovic Slobodan S.

    2012-01-01

    Full Text Available This work was aimed to analyze kinetics and mass transfer phenomena for different extraction processes from thyme (Thymus vulgaris L. leaves. Different extraction processes with ethanol were studied: Soxhlet extraction and ultrasound-assisted batch extraction on the laboratory scale as well as pilot plant batch extraction with mixing. The extraction processes with ethanol were compared to the process of supercritical carbon dioxide extraction performed at 10 MPa and 40°C. Experimental data were analyzed by mathematical model derived from the Fick’s second law to determine and compare diffusion coefficients in the periods of constant and decreasing extraction rate. In the fast extraction period, values of diffusion coefficients were one to three orders of magnitude higher compared to those determined for the period of slow extraction. The highest diffusion coefficient was reported for the fast extraction period of supercritical fluid extraction. In the case of extraction processes with ethanol, ultrasound, stirring and extraction temperature increase enhanced mass transfer rate in the washing phase. On the other hand, ultrasound contributed the most to the increase of mass transfer rate in the period of slow extraction.

  14. Coefficient of Thermal Diffusivity of Insulation Brick Developed from Sawdust and Clays

    Directory of Open Access Journals (Sweden)

    E. Bwayo

    2014-01-01

    Full Text Available This paper presents an experimental result on the effect of particle size of a mixture of ball clay, kaolin, and sawdust on thermal diffusivity of ceramic bricks. A mixture of dry powders of ball clay, kaolin of the same particle size, and sawdust of different particle sizes was mixed in different proportions and then compacted to high pressures before being fired to 950°C. The thermal diffusivity was then determined by an indirect method involving measurement of thermal conductivity, density, and specific heat capacity. The study reveals that coefficient of thermal diffusivity increases with decrease in particle size of kaolin and ball clay but decreases with increase in particle size of sawdust.

  15. Computations of ion diffusion coefficients from the Boltzmann-Fokker-Planck equation

    Science.gov (United States)

    Roussel-Dupre, R.

    1981-01-01

    The Boltzmann-Fokker-Planck equation is solved with the Chapman-Enskog method of analysis for the velocity distribution functions of helium, carbon, nitrogen, and oxygen. The analysis is a perturbation scheme based on the assumption of a collision-dominated gas, and the calculations are carried out to first order. The elements considered are treated as trace constituents in an electron-proton gas. From the resulting distribution functions, diffusion coefficients are computed which are found to be 20-30% less than those obtained by Chapman and Burgers. In addition, it is shown that the return current of cold electrons needed to maintain quasi-neutrality in a plasma with a temperature gradient contributes a term in the thermal diffusion coefficient omitted erroneously in previous works. This added term resolves the longstanding controversy over the discrepancy between the coefficients of Chapman and Burgers, which are seen to be completely equivalent in the light of this analysis. The viscosity coefficient for an electron-proton gas is also computed and found to be 7% less than that obtained by Braginskii.

  16. Correlation between apparent diffusion coefficient and viscoelasticity of articular cartilage in a porcine model.

    Science.gov (United States)

    Aoki, T; Watanabe, A; Nitta, N; Numano, T; Fukushi, M; Niitsu, M

    2012-09-01

    Quantitative MR imaging techniques of degenerative cartilage have been reported as useful indicators of degenerative changes in cartilage extracellular matrix, which consists of proteoglycans, collagen, non-collagenous proteins, and water. Apparent diffusion coefficient (ADC) mapping of cartilage has been shown to correlate mainly with the water content of the cartilage. As the water content of the cartilage in turn correlates with its viscoelasticity, which directly affects the mechanical strength of articular cartilage, ADC can serve as a potentially useful indicator of the mechanical strength of cartilage. The aim of this study was to investigate the correlation between ADC and viscoelasticity as measured by indentation testing. Fresh porcine knee joints (n = 20, age 6 months) were obtained from a local abattoir. ADC of porcine knee cartilage was measured using a 3-Tesla MRI. Indentation testing was performed on an electromechanical precision-controlled system, and viscosity coefficient and relaxation time were measured as additional indicators of the viscoelasticity of cartilage. The relationship between ADC and viscosity coefficient as well as that between ADC and relaxation time were assessed. ADC was correlated with relaxation time and viscosity coefficient (R(2) = 0.75 and 0.69, respectively, p viscoelasticity in the superficial articular cartilage. Both molecular diffusion and viscoelasticity were higher in weight bearing than non-weight-bearing articular cartilage areas.

  17. Atlas-based fiber bundle segmentation using principal diffusion directions and spherical harmonic coefficients.

    Science.gov (United States)

    Nazem-Zadeh, Mohammad-Reza; Davoodi-Bojd, Esmaeil; Soltanian-Zadeh, Hamid

    2011-01-01

    To develop an automatic atlas-based method for segmentation of fiber bundles using High Angular Resolution Diffusion Imaging (HARDI) data. Quantitative evaluation of diffusion characteristics inside specific fiber bundles provides new insights into disease developments, evolutions, therapy effects, and surgical interventions. Most of previous segmentation methods use similarity measures and strategies that do not lead to accurate segmentation results. They also suffer from subjectivity of initial seeds and regions of interest (ROI) defined by operator. We propose a novel method that uses Spherical Harmonic Coefficients (SHC) of HARDI diffusion signals to compute Orientation Distribution Function (ODF) and to extract Principal Diffusion Directions (PDDs). The proposed method selects most collinear PDD of neighbors of each voxel. Then, based on SHC and selected PDD, a similarity measure is proposed and used as a speed function in the level set framework that segments fiber bundles. To automate the process, an atlas-based method is used to select initial seeds for fiber bundles. To generate data for evaluation of the proposed method, an artificial pattern consisting of three crossing bundles intersected by a circular bundle is created. Also, two normal controls are imaged by two different HARDI protocols. Segmentation results for different fiber bundles in simulated data and normal control data are presented. Influence of threshold selection on the proposed segmentation method is evaluated using Dice coefficient. Also, effect of increasing the number of gradient directions on accuracy of extracted PDDs is evaluated. The proposed segmentation method has advantages over previous methods especially those that use similarity measures based on diffusion tensor imaging (DTI) data. These advantages are achieved by proper propagation of a hyper-surface in fiber crossing areas without making assumptions about diffusivity profile and selection of initial seeds or ROI. Copyright

  18. Numerical Solution of an Inverse Diffusion Problem for the Moisture Transfer Coefficient in a Porous Material

    CERN Document Server

    Amirkhanov, I V; Pavlus, M; Puzynina, T P; Puzynin, I V; Sarhadov, I

    2005-01-01

    On the basis of the solution of a nonlinear diffusion equation with initial and boundary conditions, a transport coefficient of moisture in a sample of a porous material is found by minimization of a functional, which expresses diversion of the computed profile of moisture concentration in well-defined time moments from their experimental values for the defined moisture transport coefficient. In this case the transport coefficient as opposed to the previous works is found as a sum of the degree and exponential functions of the moisture concentration. The exponent of the power function depends on time. Thus, a more accurate coincidence of the computed profiles of the moisture concentration with their experimental profiles is gained in comparison to previous works performed by other authors. The exponential term provides a good coincidence of the mentioned profiles for big times nearby the boundary of the sample, where evaporation of the moisture to the atmosphere takes place.

  19. How to calculate the neoclassical viscosity, diffusion, and current coefficients in general toroidal plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Sugama, H.; Nishimura, S.

    2002-05-01

    A novel method to obtain the full neoclassical transport matrix for general toroidal plasmas by using the solution of the linearized drift kinetic equation with the pitch-angle-scattering collision operator is shown. In this method, the neoclassical coefficients for both poloidal and toroidal viscosities in toroidal helical systems can be obtained, and the neoclassical transport coefficients for the radial particle and heat fluxes and the bootstrap current with the non-diagonal coupling between unlike-species particles are derived from combining the viscosity-flow relations, the friction-flow relations, and the parallel momentum balance equations. Since the collisional momentum conservation is properly retained, the well-known intrinsic ambipolar condition of the neoclassical particle fluxes in symmetric systems is recovered. Thus, these resultant neoclassical diffusion and viscosity coefficients are applicable to evaluating accurately how the neoclassical transport in quasi-symmetric toroidal systems deviates from that in exactly-symmetric systems. (author)

  20. Evaluation of the performance of thermal diffusion column separating binary gas mixtures with continuous draw-off

    International Nuclear Information System (INIS)

    Kitamoto, Asashi; Shimizu, Masami; Takashima, Yoichi

    1977-01-01

    Advanced transport relations involving three column constants, H sup(σ), K sub(c)sup(σ) and K sub(d)sup(σ), are developed to describe the separation performance of a thermal diffusion column with continuous draw-off. These constants were related to some integral functions of velocity profile, temperature distribution, density of gas mixture and characteristic values of transport coefficients. The separation of binary gas mixture by this technique was so effective that three reasonable factors had to be introduced into the column constants in the theory. They are a circulation constant of natural convection, a definition of characteristic mean temperature and a definition of mean composition over the column. The separation performance and the column constants also varied with the distortion of velocity profile due to continuous draw-off from the top or the bottom of column. However, its effect was not large, compared with the other factors mentioned above. The theory presented here makes possible to estimate the separation performance of hot-wire type thermal diffusion column with high accuracy. (auth.)

  1. Functional evaluation of hydronephrosis by diffusion-weighted MR imaging: Relationship between apparent diffusion coefficient and split glomerular filtration rate

    International Nuclear Information System (INIS)

    Toyoshima, S.; Noguchi, K.; Seto, H.; Shimizu, M.; Watanabe, N.

    2000-01-01

    To determine the relationship between apparent diffusion coefficient (ADC) values measured by diffusion-weighted MR imaging and split renal function determined by renal scintigraphy in patients with hydronephrosis. Material and Methods: Diffusion-weighted imaging on a 1.5 T MR unit and renal scintigraphy were performed in 36 patients with hydronephrosis (45 hydronephrotic kidneys, 21 non-hydronephrotic kidneys). ADC values of the individual kidneys were measured by diffusion-weighted MR imaging. Split renal function (glomerular filtration rate (GFR)) was determined by renal scintigraphy using 99m Tc-DTPA. The relationship between ADC values and split GFR was examined in 66 kidneys. The hydronephrotic kidneys were further classified into three groups (severe renal dysfunction, GFR 25 ml/min, n=28), and mean values for ADCs were calculated. Results: In hydronephrotic kidneys, there was a moderate positive correlation between ADC values and split GFR (R2=0.56). On the other hand, in non-hydronephrotic kidneys, poor correlation between ADC values and split GFR was observed (R2=0.08). The mean values for ADCs of the dysfunctioning hydronephrotic kidneys (severe renal dysfunction, 1.32x10 -3 ±0.18x10 -3 mm 2 /s; moderate renal dysfunction, 1.38x10 -3 ±0.10x10 -3 mm2/s) were significantly lower than that of the normal functioning hydronephrotic kidneys (1.63x10 -3 ±0.12±10 -3 mm 2 /s). Conclusion: These results indicated that measurement of ADC values by diffusion-weighted MR imaging has a potential value in the evaluation of the functional status of hydronephrotic kidneys

  2. Vapour pressures and osmotic coefficients of binary mixtures containing alcohol and pyrrolidinium-based ionic liquids

    International Nuclear Information System (INIS)

    Calvar, N.; Domínguez, Á.; Macedo, E.A.

    2013-01-01

    Highlights: • Osmotic coefficients of alcohols with pyrrolidinium ILs are determined. • Experimental data were correlated with extended Pitzer model of Archer and MNRTL. • Mean molal activity coefficients and excess Gibbs free energies were calculated. • The results have been interpreted in terms of interactions. -- Abstract: The osmotic and activity coefficients and vapour pressures of mixtures containing primary (1-propanol, 1-butanol and 1-pentanol) and secondary (2-propanol and 2-butanol) alcohols with pyrrolidinium-based ionic liquids (1-butyl-1-methyl pyrrolidinium bis(trifluoromethylsulfonyl)imide, C 4 MpyrNTf 2 , and 1-butyl-1-methyl pyrrolidinium trifluoromethanesulfonate, C 4 MpyrTFO) have been experimentally determined at T = 323.15 K. For the experimental measurements, the vapour pressure osmometry technique has been used. The results on the influence of the structure of the alcohol and of the anion of the ionic liquid on the determined properties have been discussed and compared with literature data. For the correlation of the osmotic coefficients obtained, the Extended Pitzer model of Archer and the Modified Non-Random Two Liquids model were applied. The mean molal activity coefficients and the excess Gibbs energy for the studied mixtures were calculated from the parameters obtained in the correlation

  3. Extracranial Soft-Tissue Tumors: Repeatability of Apparent Diffusion Coefficient Estimates from Diffusion-weighted MR Imaging.

    Science.gov (United States)

    Winfield, Jessica M; Tunariu, Nina; Rata, Mihaela; Miyazaki, Keiko; Jerome, Neil P; Germuska, Michael; Blackledge, Matthew D; Collins, David J; de Bono, Johann S; Yap, Timothy A; deSouza, Nandita M; Doran, Simon J; Koh, Dow-Mu; Leach, Martin O; Messiou, Christina; Orton, Matthew R

    2017-07-01

    Purpose To assess the repeatability of apparent diffusion coefficient (ADC) estimates in extracranial soft-tissue diffusion-weighted magnetic resonance imaging across a wide range of imaging protocols and patient populations. Materials and Methods Nine prospective patient studies and one prospective volunteer study, performed between 2006 and 2016 with research ethics committee approval and written informed consent from each subject, were included in this single-institution study. A total of 141 tumors and healthy organs were imaged twice (interval between repeated examinations, 45 minutes to 10 days, depending the on study) to assess the repeatability of median and mean ADC estimates. The Levene test was used to determine whether ADC repeatability differed between studies. The Pearson linear correlation coefficient was used to assess correlation between coefficient of variation (CoV) and the year the study started, study size, and volumes of tumors and healthy organs. The repeatability of ADC estimates from small, medium, and large tumors and healthy organs was assessed irrespective of study, and the Levene test was used to determine whether ADC repeatability differed between these groups. Results CoV aggregated across all studies was 4.1% (range for each study, 1.7%-6.5%). No correlation was observed between CoV and the year the study started or study size. CoV was weakly correlated with volume (r = -0.5, P = .1). Repeatability was significantly different between small, medium, and large tumors (P < .05), with the lowest CoV (2.6%) for large tumors. There was a significant difference in repeatability between studies-a difference that did not persist after the study with the largest tumors was excluded. Conclusion ADC is a robust imaging metric with excellent repeatability in extracranial soft tissues across a wide range of tumor sites, sizes, patient populations, and imaging protocol variations. Online supplemental material is available for this article.

  4. Diffusion-weighted magnetic resonance imaging and apparent diffusion coefficient mapping for diagnosing infectious spondylodiscitis: a preliminary study.

    Science.gov (United States)

    Chen, Tai-Yuan; Wu, Te-Chang; Tsui, Yu-Kun; Chen, Hou-Hsun; Lin, Chien-Jen; Lee, Huey-Jen; Wu, Tai-Ching

    2015-01-01

    Though diffusion-weighted (DW) magnetic resonance imaging (MRI) is useful for diagnosing many pathologies, its use in infectious spondylodiscitis is unclear. We aimed to evaluate the use of DW MRI and apparent diffusion coefficient (ADC) mapping for the diagnosis of infectious spondylodiscitis. In this retrospective study, 17 patients with confirmed infectious spondylodiscitis were matched by age and level of infected disc with 17 patients with degenerative disc disease (DDD) and 17 healthy controls. All patients received conventional MRI and diffusion-weighted imaging (DWI) in the same imaging session. ADC values of the 3 groups of patients were compared. The mean age of each group was 67.4 ± 11.6 years. The mean ADCs of the normal control, DDD, and infectious spondylodiscitis groups were 1.76 ± 0.19 × 10(-3) , 1.12 ± 0.22 × 10(-3) , and 1.27 ± 0.38 × 10(-3) mm2 /second, respectively. The ADCs of the DDD and infectious spondylodiscitis groups were both significantly lower than that of the normal control group (both, P spondylodiscitis. © 2014 The Authors. Journal of Neuroimaging published by Wiley Periodicals, Inc. on behalf of American Society of Neuroimaging.

  5. Cosmic-Ray Diffusion Coefficients throughout the Inner Heliosphere from a Global Solar Wind Simulation

    Science.gov (United States)

    Chhiber, R.; Subedi, P.; Usmanov, A. V.; Matthaeus, W. H.; Ruffolo, D. J.; Goldstein, M. L.; Parashar, T.

    2017-12-01

    We use a three-dimensional magnetohydrodynamic simulation of the solar wind to calculate cosmic-ray diffusion coefficients throughout the inner heliosphere. The simulation resolves large-scale solar wind flow, which is coupled to small-scale fluctuations through a turbulence model. Simulation results specify background solar wind fields and turbulence parameters, which are used to compute diffusion coefficients and study their behavior in the inner heliosphere. The parallel mean free path (mfp) is evaluated using quasi-linear theory, while the perpendicular mfp is determined from nonlinear guiding center theory with the random ballistic interpretation. Several runs examine varying turbulent energy and different solar source dipole tilts. We find that for most of the inner heliosphere, the radial mfp is dominated by diffusion parallel to the mean magnetic field; the parallel mfp remains at least an order of magnitude larger than the perpendicular mfp, except in the heliospheric current sheet, where the perpendicular mfp may be a few times larger than the parallel mfp. In the ecliptic region, the perpendicular mfp may influence the radial mfp at heliocentric distances larger than 1.5 au; our estimations of the parallel mfp in the ecliptic region at 1 au agree well with the Palmer "consensus" range of 0.08-0.3 au. Solar activity increases perpendicular diffusion and reduces parallel diffusion. The parallel mfp mostly varies withrigidity (P) as P.33, and the perpendicular mfp is weakly dependent on P. The mfps are weakly influenced by the choice of long-wavelength power spectra.

  6. Estimating apparent diffusion coefficient and tortuosity in packed sand columns by tracers experiments

    International Nuclear Information System (INIS)

    Latrille, Ch.; Zoia, A.

    2011-01-01

    In this work we analyze the spatial and temporal features of the transport parameters characterizing the apparent diffusion coefficient and tortuosity along an experimental setup. To perform this study, we resort to the BEETI device, consisting of a vertical column filled with porous materials and of a dichromatic X-ray spectrometer for detecting solute distribution. X-ray measures are noninvasive and nondestructive, and thus allow determining the solute concentration profiles at several locations along the column, as a function of time. Once the concentration profiles are experimentally measured, the transport parameters v(x) and D(x) are determined at each location by means of the method of temporal moments. Two sets of experimental runs are performed (at high and low flow rates, respectively), in order to single out the effects of mechanical dispersion and molecular diffusion on the overall solute dispersion. Further manipulations allow finally deriving the spatial evolution of the apparent molecular diffusion coefficient and of the tortuosity. The estimated tortuosity values are compared with literature results and show good agreement. This analysis relies on the hypothesis that the traversed porous medium is sufficiently homogeneous and can be used as a benchmark in view of testing our experimental device on more complex soils. (authors)

  7. Measurement of Retinalamin diffusion coefficient in human sclera by optical spectroscopy

    Science.gov (United States)

    Genina, Elina A.; Bashkatov, Alexey N.; Zubkova, Elena A.; Kamenskikh, Tatiana G.; Tuchin, Valery V.

    2008-12-01

    The use of cytomedines (such as Retinalamin) in clinical practice has shown high effectiveness of the medicaments in ophthalmology. The study of diffusion of Retinalamin in scleral tissue is important for estimation of a drug dose delivered into inner tissue of eye, time of drug action, etc. In vitro measurements of spectral reflectance of sclera interacting with aqueous solution of Retinalamin have been carried out. Ten human sclera samples were included in the study. The results of the experiments have shown that penetration of Retinalamin into scleral tissue leads to the decrease of scleral reflectance due to optical immersion. Estimation of diffusion coefficient of studied solution has been made on the basis of analysis of optical reflectance dynamics of the sclera samples. The diffusion coefficient of Retinalamin in human scleral tissue was evaluated as (1.82±0.14)×10 -6 cm 2/s. The results are important for treatment of partial optic atrophy observed at primary open-angle glaucoma and others eye diseases.

  8. Ab initio calculation of oxygen self-diffusion coefficient in uranium dioxide UO2

    Science.gov (United States)

    Dorado, Boris; Garcia, Philippe; Torrent, Marc

    Uranium dioxide UO2 is the most widely used nuclear fuel worldwide and its atomic transport properties are relevant to practically all engineering aspects of the material. Although transport properties have already been studied in UO2 by means of first-principles calculations, the ab initio determination of self-diffusion coefficients has up to now remained unreachable because the relevant computational tools were neither available or adapted. The present work reports our results related to the ab initio calculation of the oxygen self-diffusion coefficient in UO2. We first determine the Gibbs free energies of formation of oxygen charged defects by calculating both the electronic and vibrational (hence entropic) contributions. Then, we use the transition state theory in order to compute the effective jump frequency of the defects, which in turn provides us with the value of the pre-exponential factor. The results are compared to self-diffusion data obtained experimentally with a careful monitoring of the relevant thermodynamic conditions (oxygen partial pressure, temperature, impurity content).

  9. Migration of oligomers from PET: determination of diffusion coefficients and comparison of experimental versus modelled migration.

    Science.gov (United States)

    Hoppe, Maria; Fornari, Roberta; de Voogt, Pim; Franz, Roland

    2017-07-01

    Polyethylene terephthalate (PET) is increasingly used as food-contact material in, for example, containers for beverage such as bottles for soft drinks, mineral water, juices and beer. Mass transport of substances present in packaging materials into the packed food and beverages is monitored to verify the food law compliance of the materials. PET is known to contain or give rise to migrants that are oligomers derived from the polymeric material. Until now their actual migration potential has been investigated only poorly. A convenient way to determine their migration would be by using models. To verify existing models with experimental data, a migration kinetic study of PET oligomers was conducted. PET bottle material was submerged in 50% ethanol at 80°C for 15 h. The oligomer content in the migration solutions was determined every hour using LC-MS with the first-series cyclic PET trimer as standard. Diffusion coefficients of five PET oligomers (first-series dimer and trimer, second-series dimer and trimer, and third-series dimer) were calculated from the obtained data and compared with the calculated diffusion coefficients using the models of Welle and Piringer. This is the first study to provide diffusion characteristics of oligomers in PET other than the first-series cyclic trimer.

  10. EVOLUTION OF THE MAGNETIC FIELD LINE DIFFUSION COEFFICIENT AND NON-GAUSSIAN STATISTICS

    Energy Technology Data Exchange (ETDEWEB)

    Snodin, A. P. [Department of Mathematics, Faculty of Applied Science, King Mongkut’s University of Technology North Bangkok, Bangkok 10800 (Thailand); Ruffolo, D. [Department of Physics, Faculty of Science, Mahidol University, Bangkok 10400 (Thailand); Matthaeus, W. H. [Bartol Research Institute and Department of Physics and Astronomy, University of Delaware, Newark, DE 19716 (United States)

    2016-08-20

    The magnetic field line random walk (FLRW) plays an important role in the transport of energy and particles in turbulent plasmas. For magnetic fluctuations that are transverse or almost transverse to a large-scale mean magnetic field, theories describing the FLRW usually predict asymptotic diffusion of magnetic field lines perpendicular to the mean field. Such theories often depend on the assumption that one can relate the Lagrangian and Eulerian statistics of the magnetic field via Corrsin’s hypothesis, and additionally take the distribution of magnetic field line displacements to be Gaussian. Here we take an ordinary differential equation (ODE) model with these underlying assumptions and test how well it describes the evolution of the magnetic field line diffusion coefficient in 2D+slab magnetic turbulence, by comparisons to computer simulations that do not involve such assumptions. In addition, we directly test the accuracy of the Corrsin approximation to the Lagrangian correlation. Over much of the studied parameter space we find that the ODE model is in fairly good agreement with computer simulations, in terms of both the evolution and asymptotic values of the diffusion coefficient. When there is poor agreement, we show that this can be largely attributed to the failure of Corrsin’s hypothesis rather than the assumption of Gaussian statistics of field line displacements. The degree of non-Gaussianity, which we measure in terms of the kurtosis, appears to be an indicator of how well Corrsin’s approximation works.

  11. Apparent diffusion coefficient measurement in a moving phantom simulating linear respiratory motion

    International Nuclear Information System (INIS)

    Kwee, T.C.; Takahara, Taro; Nievelstein, R.A.J.; Mali, W.P.T.M.; Luijten, P.R.; Muro, Isao; Imai, Yutaka; Cauteren, M. Van

    2010-01-01

    The aim of this study was to examine the effect of simulated linear respiratory motion on apparent diffusion coefficient (ADC) measurements. Six rectangular test tubes (14 x 92 mm) filled with either water, tomato ketchup, or mayonnaise were positioned in a box containing agarose gel. This box was connected to a double-acting pneumatic cylinder, capable of inducing periodic linear motion in the long-axis direction of the magnetic bore (23-mm stroke). Diffusion-weighted magnetic resonance imaging was performed for both the static and moving phantoms, and ADC measurements were made in the six test tubes in both situations. In the three test tubes whose long axes were parallel to the direction of motion, ADCs agreed well between the moving and static phantom situations. However, in two test tubes that were filled with fluids that had a considerably lower diffusion coefficient than the surrounding agarose gel, and whose long axes were perpendicular to the direction of motion, the ADCs agreed poorly between the moving and static phantom situations. ADC measurements of large homogeneous structures are not affected by linear respiratory motion. However, ADC measurements of inhomogeneous or small structures are affected by linear respiratory motion due to partial volume effects. (author)

  12. Apparent diffusion coefficient measurement in glioma: Influence of region-of-interest determination methods on apparent diffusion coefficient values, interobserver variability, time efficiency, and diagnostic ability.

    Science.gov (United States)

    Han, Xu; Suo, Shiteng; Sun, Yawen; Zu, Jinyan; Qu, Jianxun; Zhou, Yan; Chen, Zengai; Xu, Jianrong

    2017-03-01

    To compare four methods of region-of-interest (ROI) placement for apparent diffusion coefficient (ADC) measurements in distinguishing low-grade gliomas (LGGs) from high-grade gliomas (HGGs). Two independent readers measured ADC parameters using four ROI methods (single-slice [single-round, five-round and freehand] and whole-volume) on 43 patients (20 LGGs, 23 HGGs) who had undergone 3.0 Tesla diffusion-weighted imaging and time required for each method of ADC measurements was recorded. Intraclass correlation coefficients (ICCs) were used to assess interobserver variability of ADC measurements. Mean and minimum ADC values and time required were compared using paired Student's t-tests. All ADC parameters (mean/minimum ADC values of three single-slice methods, mean/minimum/standard deviation/skewness/kurtosis/the10 th and 25 th percentiles/median/maximum of whole-volume method) were correlated with tumor grade (low versus high) by unpaired Student's t-tests. Discriminative ability was determined by receiver operating characteristic curves. All ADC measurements except minimum, skewness, and kurtosis of whole-volume ROI differed significantly between LGGs and HGGs (all P methods had good to excellent ICCs (0.67-0.89) and the whole-volume method fair to excellent ICCs (0.32-0.96). Minimum ADC values differed significantly between whole-volume and single-round ROI (P = 0.003) and, between whole-volume and five-round ROI (P = 0.001). The whole-volume method took significantly longer than all single-slice methods (all P measurements are influenced by ROI determination methods. Whole-volume histogram analysis did not yield better results than single-slice methods and took longer. Mean ADC value derived from single-round ROI is the most optimal parameter for differentiating LGGs from HGGs. 3 J. Magn. Reson. Imaging 2017;45:722-730. © 2016 International Society for Magnetic Resonance in Medicine.

  13. Desorption modeling of hydrophobic organic chemicals from plastic sheets using experimentally determined diffusion coefficients in plastics.

    Science.gov (United States)

    Lee, Hwang; Byun, Da-Eun; Kim, Ju Min; Kwon, Jung-Hwan

    2018-01-01

    To evaluate rate of migration from plastic debris, desorption of model hydrophobic organic chemicals (HOCs) from polyethylene (PE)/polypropylene (PP) films to water was measured using PE/PP films homogeneously loaded with the HOCs. The HOCs fractions remaining in the PE/PP films were compared with those predicted using a model characterized by the mass transfer Biot number. The experimental data agreed with the model simulation, indicating that HOCs desorption from plastic particles can generally be described by the model. For hexachlorocyclohexanes with lower plastic-water partition coefficients, desorption was dominated by diffusion in the plastic film, whereas desorption of chlorinated benzenes with higher partition coefficients was determined by diffusion in the aqueous boundary layer. Evaluation of the fraction of HOCs remaining in plastic films with respect to film thickness and desorption time showed that the partition coefficient between plastic and water is the most important parameter influencing the desorption half-life. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. A systematic determination of diffusion coefficients of trace elements in open and restricted diffusive layers used by the diffusive gradients in a thin film technique

    Energy Technology Data Exchange (ETDEWEB)

    Shiva, Amir Houshang; Teasdale, Peter R., E-mail: p.teasdale@griffith.edu.au; Bennett, William W.; Welsh, David T.

    2015-08-12

    A systematic comparison of the diffusion coefficients of cations (Al, Cd, Co, Cu, Mn, Ni, Pb, Zn) and oxyanions (Al, As, Mo, Sb, V, W) in open (ODL) and restricted (RDL) diffusive layers used by the DGT technique was undertaken. Diffusion coefficients were measured using both the diffusion cell (D{sub cell}) method at pH 4.00 and the DGT time-series (D{sub DGT}) method at pH 4.01 and 7.04 (pH 8.30 was used instead of 7.04 for Al) using the Chelex-Metsorb mixed binding layer. The performance of Chelex-Metsorb as a new DGT binding layer for Al uptake was also evaluated for the first time. Reasonable agreement was observed between D{sub cell} and D{sub DGT} measurements for both ODL and RDL, except for V and W. The ratios of D{sub cell}/D{sub DGT} for V of 0.44 and 0.39, and for W of 0.66 and 0.63 with ODL and RDL respectively, were much lower due to the formation of a high proportion of polyoxometalate species at the higher concentrations required with the D{sub cell} measurements. This is the first time that D values have been reported for several oxyanions using RDL. Except for Al at pH 8.30 with ODL, all D{sub DGT} measurements were retarded relative to diffusion coefficients in water (D{sub W}) for both diffusive hydrogels. Diffusion in RDL was further retarded compared with ODL, for all elements (0.66–0.78) with both methods. However, the degree of retardation observed changed for cations and anions at each pH. At pH 7.04 cations had a slightly higher D{sub DGT} and oxyanions had a slightly lower D{sub DGT} than at pH 4.01 for both ODL and RDL. It is proposed that this is due to partial formation of acrylic acid functional groups (pK{sub a} ≈4.5), which would be fully deprotonated at pH 7.04 (negative) and mostly protonated at pH 4.01 (neutral). As Al changes from being cationic at pH 4.01 to anionic at pH 8.30 the results were more complex. - Highlights: • Determining elemental diffusion coefficients in open and restricted diffusive gels. • The DGT

  15. Preliminary evaluation of the apparent diffusion coefficient of the kidney with a spiral IVIM sequence

    International Nuclear Information System (INIS)

    Tsuda, Kyo; Murakami, Takamichi; Sakurai, Kousuke

    1997-01-01

    We examined the usefulness of the spiral intravoxel incoherent motion (IVIM) sequence in measuring the apparent diffusion coefficient (ADC) of the kidneys. Five volunteers and five patients with chronic renal failure underwent diffusion-sensitive magnetic resonance imaging of the kidneys with the spiral IVIM sequence. The ADC values in patients with chronic renal failure were significantly lower than those in the renal cortex of volunteers. The mean value of ADC in patients with chronic renal failure was lower than that in volunteers, although there was no statistically significant difference. In volunteers, the ADC of the renal cortex was significantly higher than that of the renal medulla. The phantom study indicated that the accuracy of ADC depended on the signal to noise ratio. A spiral IVIM sequence with a high enough signal to noise ratio may be useful in evaluating renal function, especially that of the cortex. (author)

  16. Apparent diffusion coefficients of normal uterus in premenopausal women with 3 T MRI

    International Nuclear Information System (INIS)

    Kuang, F.; Chen, Z.; Zhong, Q.; Fu, L.; Ma, M.

    2013-01-01

    Aim: To investigate the apparent diffusion coefficient (ADC) values of the normal uterine cervical zonal structures (cervical epithelium, the junctional zone, and myometrium) during different phases of the menstrual cycle among premenopausal women in different age groups. Materials and methods: Seventy healthy women, who were divided into three age groups (group A, 24 women in their twenties; group B, 23 women in their thirties; group C, 23 women in their forties), underwent 3 T magnetic resonance imaging (MRI) with T2-weighted and diffusion-weighted imaging (DWI) during the mid-proliferative and the mid-secretory phases. Results: The ADC values of each cervical zonal structure were significantly different from one another (p 0.05). Conclusion: ADC values of normal cervical epithelium and the junctional zone change with different phases of the menstrual cycle, which should be taken into consideration when early cervical disease is detected, when monitoring treatment response, and differentiating early tumour recurrence

  17. Apparent diffusion coefficient of the renal tissue. The effect of diuretic

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, Jin; Munechika, Hirotsugu [Showa Univ., Tokyo (Japan). School of Medicine

    1998-12-01

    Apparent diffusion coefficient (ADC) of the renal tissue was studied at diffusion-weighted images of the kidney which were obtained from spin-echo type sequence before and after furosemide (100 mg) injection in twelve healthy volunteers. ADC (mm{sup 2}/sec) of the renal cortex and medulla before furosemide injection was 2.08{+-}0.52 and 1.96{+-}0.52, respectively. No appreciable ADC difference was seen between the cortex and the medulla of the kidney. After furosemide injection, ADC of the renal cortex and medulla became 2.09{+-}0.42 and 1.78{+-}0.38, respectively. It was found that furosemide produced no significant effect on ADC of the renal tissue. (author)

  18. Oxygen Chemical Diffusion Coefficients of (Pu,Am)O2 Fuels

    International Nuclear Information System (INIS)

    Watanabe, M.; Kato, M.; Matsumoto, T.

    2015-01-01

    Minor actinide (MA)-bearing MOX fuels have been developed as candidate fuels which are used in fast neutron spectrum cores such as sodium-cooled fast reactor (SFR) cores and experimental accelerator driven system (ADS) cores. Americium (Am) which is one of the MA elements significantly affects basic properties. It is known that Am content causes oxygen potential to increase and that influences irradiation behaviour such as fuel-cladding chemical interaction (FCCI) and chemical state of fission products. However, the effects of Am content on changes of basic properties are not clear. In this work, the oxygen chemical diffusion coefficients were calculated from measured data and the relationship between oxygen diffusion and oxygen potential of (Pu,Am)O 2-x was discussed. (authors)

  19. A finite difference method for space fractional differential equations with variable diffusivity coefficient

    KAUST Repository

    Mustapha, K.

    2017-06-03

    Anomalous diffusion is a phenomenon that cannot be modeled accurately by second-order diffusion equations, but is better described by fractional diffusion models. The nonlocal nature of the fractional diffusion operators makes substantially more difficult the mathematical analysis of these models and the establishment of suitable numerical schemes. This paper proposes and analyzes the first finite difference method for solving {\\\\em variable-coefficient} fractional differential equations, with two-sided fractional derivatives, in one-dimensional space. The proposed scheme combines first-order forward and backward Euler methods for approximating the left-sided fractional derivative when the right-sided fractional derivative is approximated by two consecutive applications of the first-order backward Euler method. Our finite difference scheme reduces to the standard second-order central difference scheme in the absence of fractional derivatives. The existence and uniqueness of the solution for the proposed scheme are proved, and truncation errors of order $h$ are demonstrated, where $h$ denotes the maximum space step size. The numerical tests illustrate the global $O(h)$ accuracy of our scheme, except for nonsmooth cases which, as expected, have deteriorated convergence rates.

  20. Association between visual degeneration of intervertebral discs and the apparent diffusion coefficient.

    Science.gov (United States)

    Niinimäki, Jaakko; Korkiakoski, Arto; Ojala, Outi; Karppinen, Jaro; Ruohonen, Jyrki; Haapea, Marianne; Korpelainen, Raija; Natri, Antero; Tervonen, Osmo

    2009-06-01

    The value of apparent diffusion coefficient (ADC) measurements in intervertebral disc has been studied because ADC provides an estimate of free diffusion of unbound water and could be used as a quantitative tool to estimate degenerative changes. However, the challenging nature of diffusion imaging of spine and limited numbers of subjects in earlier studies has produced contradictory findings. We aimed to determine the relation between ADC and visual degenerative changes in lumbar intervertebral discs in a sufficiently large homogeneous study group. Lumbar spines of 228 volunteer middle-aged men were MR imaged at 1.5 T including anatomic and diffusion-weighted imaging. ADC values, T2 signal intensity and height, and width of the three lowest lumbar intervertebral discs were measured and disc degeneration visually graded. The calculated average ADC of 530 measured discs was 2.01 x 10(-3) mm(2)/s+/-0.29 (+/-S.D.). The reduction in ADC between visually normal and moderately degenerated discs was 4%. Severely degenerated discs showed 5% larger ADC values than normal discs, presumably due to free water in cracks and fissures of those discs. T2 signal intensity of the disc was significantly correlated with the ADC values, whereas other measured parameters did not show correlation. There was no evident difference in ADC between the studied anatomic lumbar levels. Because there is considerable overlap between ADC values of normal and degenerated discs, we conclude that ADC measurements of intervertebral discs, at least with current technology, have limited clinical value.

  1. Practical estimate of gradient nonlinearity for implementation of apparent diffusion coefficient bias correction.

    Science.gov (United States)

    Malkyarenko, Dariya I; Chenevert, Thomas L

    2014-12-01

    To describe an efficient procedure to empirically characterize gradient nonlinearity and correct for the corresponding apparent diffusion coefficient (ADC) bias on a clinical magnetic resonance imaging (MRI) scanner. Spatial nonlinearity scalars for individual gradient coils along superior and right directions were estimated via diffusion measurements of an isotropicic e-water phantom. Digital nonlinearity model from an independent scanner, described in the literature, was rescaled by system-specific scalars to approximate 3D bias correction maps. Correction efficacy was assessed by comparison to unbiased ADC values measured at isocenter. Empirically estimated nonlinearity scalars were confirmed by geometric distortion measurements of a regular grid phantom. The applied nonlinearity correction for arbitrarily oriented diffusion gradients reduced ADC bias from 20% down to 2% at clinically relevant offsets both for isotropic and anisotropic media. Identical performance was achieved using either corrected diffusion-weighted imaging (DWI) intensities or corrected b-values for each direction in brain and ice-water. Direction-average trace image correction was adequate only for isotropic medium. Empiric scalar adjustment of an independent gradient nonlinearity model adequately described DWI bias for a clinical scanner. Observed efficiency of implemented ADC bias correction quantitatively agreed with previous theoretical predictions and numerical simulations. The described procedure provides an independent benchmark for nonlinearity bias correction of clinical MRI scanners.

  2. The diffusive logistic equation with a free boundary and sign-changing coefficient

    Science.gov (United States)

    Wang, Mingxin

    2015-02-01

    This short paper concerns a diffusive logistic equation with a free boundary and sign-changing coefficient, which is formulated to study the spread of an invasive species, where the free boundary represents the expanding front. A spreading-vanishing dichotomy is derived, namely the species either successfully spreads to the right-half-space as time t → ∞ and survives (persists) in the new environment, or it fails to establish itself and will extinct in the long run. The sharp criteria for spreading and vanishing are also obtained. When spreading happens, we estimate the asymptotic spreading speed of the free boundary.

  3. Measurements of the electron particle diffusion coefficient with the JET multichannel reflectometer

    International Nuclear Information System (INIS)

    Sips, A.C.C.; Haas, J.C.M. de; Costley, A.E.; Prentice, R.

    1989-01-01

    Experimental determinations of the cross-field particle diffusion coefficient (D p ) are important in studies of transport in tokamak plasmas. D p has been determined from measurements of density perturbations following a sawtooth collapse, oscillating gas puff, and injected high velocity pellets. In each case the density changes have been measured using multichord interferometry and D p is obtained with an accuracy of typically 20%. In this paper, we present our most recent measurements of D p . The experimental data are compared with the prediction of a comprehensive numerical transport model which includes both outward going and inward going density pulses. (author) 8 refs., 6 figs

  4. Compilation and evaluation of gas phase diffusion coefficients of reactive trace gases in the atmosphere: volume 1. Inorganic compounds

    Science.gov (United States)

    Tang, M. J.; Cox, R. A.; Kalberer, M.

    2014-09-01

    Diffusion of gas molecules to the surface is the first step for all gas-surface reactions. Gas phase diffusion can influence and sometimes even limit the overall rates of these reactions; however, there is no database of the gas phase diffusion coefficients of atmospheric reactive trace gases. Here we compile and evaluate, for the first time, the diffusivities (pressure-independent diffusion coefficients) of atmospheric inorganic reactive trace gases reported in the literature. The measured diffusivities are then compared with estimated values using a semi-empirical method developed by Fuller et al. (1966). The diffusivities estimated using Fuller's method are typically found to be in good agreement with the measured values within ±30%, and therefore Fuller's method can be used to estimate the diffusivities of trace gases for which experimental data are not available. The two experimental methods used in the atmospheric chemistry community to measure the gas phase diffusion coefficients are also discussed. A different version of this compilation/evaluation, which will be updated when new data become available, is uploaded online (google.com/site/mingjintang/home/diffusion"target="_blank">https://sites.google.com/site/mingjintang/home/diffusion).

  5. Determination of partition and diffusion coefficients of formaldehyde in selected building materials and impact of relative humidity.

    Science.gov (United States)

    Xu, Jing; Zhang, Jianshun S; Liu, Xiaoyu; Gao, Zhi

    2012-06-01

    The partition and effective diffusion coefficients of formaldehyde were measured for three materials (conventional gypsum wallboard, "green" gypsum wallboard, and "green" carpet) under three relative humidity (RH) conditions (20%, 50%, and 70% RH). The "green" materials contained recycled materials and were friendly to environment. A dynamic dual-chamber test method was used. Results showed that a higher relative humidity led to a larger effective diffusion coefficient for two kinds of wallboards and carpet. The carpet was also found to be very permeable resulting in an effective diffusion coefficient at the same order of magnitude with the formaldehyde diffusion coefficient in air. The partition coefficient (K(ma)) of formaldehyde in conventional wallboard was 1.52 times larger at 50% RH than at 20% RH, whereas it decreased slightly from 50% to 70% RH, presumably due to the combined effects of water solubility of formaldehyde and micro-pore blocking by condensed moisture at the high RH level. The partition coefficient of formaldehyde increased slightly with the increase of relative humidity in "green" wallboard and "green" carpet. At the same relative humidity level, the "green" wallboard had larger partition coefficient and effective diffusion coefficient than the conventional wallboard, presumably due to the micro-pore structure differences between the two materials. The data generated could be used to assess the sorption effects of formaldehyde on building materials and to evaluate its impact on the formaldehyde concentration in buildings.

  6. Glucocorticoid treatment of brain tumor patients: changes of apparent diffusion coefficient values measured by MR diffusion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Minamikawa, Sosuke; Kono, Kinuko; Nakayama, Keiko; Yokote, Hiroyuki; Tashiro, Takahiko; Inoue, Yuichi [Osaka City University Graduate School of Medicine, Department of Radiology, Osaka (Japan); Nishio, Akimasa; Hara, Mitsuhiro [Osaka City University Graduate School of Medicine, Department of Neurosurgery, Osaka (Japan)

    2004-10-01

    Glucocorticoids (GCC) generally are administered to patients with brain tumors to relieve neurological symptoms by decreasing the water content in a peritumoral zone of edema. We hypothesized that diffusion imaging and apparent diffusion coefficient (ADC) values could detect subtle changes of water content in brain tumors and in peritumoral edema after GCC therapy. The study consisted of 13 patients with intra-axial brain tumor, and ADC was measured in the tumor, within peritumoral edema, and in normal white matter remote from the tumor before and after GCC therapy. ADC also was measured in normal white matter in four control patients with no intracranial disease who were treated with GCC for other indications. Conventional MR images showed no visually evident interval change in tumor size or the extent of peritumoral edema in any subject after GCC therapy, which nonetheless resulted in a decrease in mean ADC of 7.0% in tumors (P<0.05), 1.8% in peritumoral edema (P>0.05, not significant) and 5.8% in normal white matter (P<0.05). In patients with no intracranial disease, GCC therapy decreased mean ADC in white matter by 5.4% (P<0.05). ADC measurement can demonstrate subtle changes in the brain after GCC therapy that cannot be observed by conventional MR imaging. Measurement of ADC proved to be a sensitive means of assessing the effect of GCC therapy, even in the absence of visually discernible changes in conventional MR images. (orig.)

  7. Apparent diffusion coefficient measurement by diffusion weighted magnetic resonance imaging is a useful tool in differentiating renal tumors.

    Science.gov (United States)

    Liu, Jing-Hong; Tian, Shi-Feng; Ju, Ye; Li, Ye; Chen, An-Liang; Chen, Li-Hua; Liu, Ai-Lian

    2015-04-16

    To determine the clinical value of apparent diffusion coefficient (ADC) measurement by diffusion weighted magnetic resonance imaging (DW-MRI) in differentiating renal tumors. Electronic databases were searched using combinations of keywords and free words relating to renal tumor, ADC and DW-MRI. Based on carefully selected inclusion and exclusion criteria, relevant case-control studies were identified and the related clinical data was acquired. Statistical analyses were performed using STATA 12.0 (Stata Corporation, College station, TX). Sixteen case-control studies were ultimately included in the present meta-analysis. These 16 high quality studies contained a combined total of 438 normal renal tissues and 832 renal tumor lesions (597 malignant and 235 benign). The results revealed that ADC values of malignant renal tumor tissues were markedly lower than normal renal tissues and benign renal tumor tissues. ADC values of benign renal tumor tissues were also significantly lower than normal renal tissue. ADC measurement by DW-MRI provided clinically useful information on the internal structure of renal tumors and could be an important radiographic index for differentiation of malignant renal tumors from benign renal tumors.

  8. Reproductibility of apparent diffusion coefficients measurements in diffusion-weighted MRI of the abdomen with different b values

    International Nuclear Information System (INIS)

    Bilgili, Mirace Yasemin Karadeniz

    2012-01-01

    Purpose: To test the reproducibility of apparent diffusion coefficients (ADC) measurements of the normal liver, kidney and spleen parenchyma with different b values. Materials and methods: Eleven healthy volunteers were imaged twice with use of the same protocol. Each DWI was performed with b-factors of 0, 100 and 500 s/mm 2 . The ADCs were organized according to session (1 or 2), anatomic location and repetition (twice with two different b value per session). The ADC data were analyzed with repeated-measures analysis of variance to demonstrate the influence of anatomic location, session and different b values. The coefficient of variation was calculated for each subject, b value and anatomic location, then analyzed by using repeated-measures analysis of variance. Results: There were significant differences in mean ADCs among the three anatomic locations and with different b values (P .05). The CV values range between 7.3% and 14.7%. There were no significant differences in CV values neither between the two b values nor for the various organ locations (P > .05). Conclusion: Using the same technical parameters, patients and the same observer, CV values range between 7.3% and 14.7%. And we recommend to be careful in examination and comparison of the measured ADC values, below these limits, without knowledge technical parameters that has been used, otherwise differences that are merely because of changes in the measurement technique could be interpreted as differences because of progression of disease or therapy

  9. Diffusion-weighted MR imaging in laryngeal and hypopharyngeal carcinoma: association between apparent diffusion coefficient and histologic findings.

    Science.gov (United States)

    Driessen, Juliette P; Caldas-Magalhaes, Joana; Janssen, Luuk M; Pameijer, Frank A; Kooij, Nina; Terhaard, Chris H J; Grolman, Wilko; Philippens, Marielle E P

    2014-08-01

    To investigate the relationship between the histologic characteristics of head and neck squamous cell carcinoma and apparent diffusion coefficient (ADC) at diffusion-weighted magnetic resonance (MR) imaging. The institutional ethics committee approved this study and waived informed consent. In head and neck squamous cell carcinoma, local failure after chemotherapy and/or radiation therapy correlates with pretreatment ADC. However, the histopathologic basis of this correlation remains unclear. In this study, 16 patients with head and neck squamous cell carcinoma were enrolled (median age, 60 years; range, 49-78 years). Before undergoing total laryngectomy, patients underwent 1.5-T diffusion-weighted MR imaging. After resection, whole-mount hematoxylin-eosin-stained sections were registered to the MR images. Cellular density; nuclear, cytoplasmic, and stromal area; and nuclear-cytoplasmic ratio within the tumor were calculated by using image-based segmentation on four consecutive slices. Mean ADC of the corresponding tumor region was calculated. Spearman correlations between ADC and histologic characteristics were calculated. ADC was significantly and inversely correlated with cell density (n = 16, r = -0.57, P = .02), nuclear area (n = 12, r = -0.64, P = .03), and nuclear-cytoplasmic ratio (n = 12, r = -0.77, P ≤ .01). ADC was significantly and positively correlated with percentage area of stroma (n = 12, r = 0.69, P = .01). Additionally, the percentage area of stroma was strongly interdependent with the percentage area of nuclei (n = 12, r = -0.97, P ≤ .01). ADC was significantly correlated with cellularity, stromal component, and nuclear-cytoplasmic ratio. The positive correlation of ADC and stromal component suggests that the poor prognostic value of high pretreatment ADC might partly be attributed to the tumor-stroma component, a known predictor of local failure.

  10. Determination of partition and diffusion coefficient of formaldehyde in selected building materials and impact of relative humidity

    Science.gov (United States)

    The partition and effective diffusion coefficients of formaldehyde were measured for three materials (conventional gypsum wallboard, "green" gypsum wallboard, and "green" carpet) under three relative humidity (RH) conditions (20%, 50% and 70% RH). A dynamic dual-chamber test meth...

  11. Determination of partition and diffusion coefficients of formaldehyde in selected building materials and impact of relative humidity (journal)

    Science.gov (United States)

    The partition and effective diffusion coefficients of formaldehyde were measured for three materials (conventional gypsum wallboard, "green" gypsum wallboard, and "green" carpet) under three relative humidity (RH) conditions (20%, 50% and 70% RH). A dynamic dual-chamber test meth...

  12. Interpatient variation in normal peripheral zone apparent diffusion coefficient: effect on the prediction of prostate cancer aggressiveness

    NARCIS (Netherlands)

    Litjens, G.J.S.; Hambrock, T.; Hulsbergen-van de Kaa, C.A.; Barentsz, J.O.; Huisman, H.J.

    2012-01-01

    Purpose: To determine the interpatient variability of prostate peripheral zone (PZ) apparent diffusion coefficient (ADC) and its effect on the assessment of prostate cancer aggressiveness. Materials and Methods: The requirement for institutional review board approval was waived. Intra- and

  13. Brownian dynamics simulations of the self- and collective rotational diffusion coefficients of rigid long thin rods

    Science.gov (United States)

    Tao, Yu-Guo; den Otter, W. K.; Padding, J. T.; Dhont, J. K. G.; Briels, W. J.

    2005-06-01

    Recently a microscopic theory for the dynamics of suspensions of long thin rigid rods was presented, confirming and expanding the well-known theory by Doi and Edwards [The Theory of Polymer Dynamics (Clarendon, Oxford, 1986)] and Kuzuu [J. Phys. Soc. Jpn. 52, 3486 (1983)]. Here this theory is put to the test by comparing it against computer simulations. A Brownian dynamics simulation program was developed to follow the dynamics of the rods, with a length over a diameter ratio of 60, on the Smoluchowski time scale. The model accounts for excluded volume interactions between rods, but neglects hydrodynamic interactions. The self-rotational diffusion coefficients Dr(φ) of the rods were calculated by standard methods and by a new, more efficient method based on calculating average restoring torques. Collective decay of orientational order was calculated by means of equilibrium and nonequilibrium simulations. Our results show that, for the currently accessible volume fractions, the decay times in both cases are virtually identical. Moreover, the observed decay of diffusion coefficients with volume fraction is much quicker than predicted by the theory, which is attributed to an oversimplification of dynamic correlations in the theory.

  14. Estimation of diffusion coefficients in bitumen solvent mixtures as derived from low field NMR spectra

    International Nuclear Information System (INIS)

    Wen, Y.; Bryan, J.; Kantzas, A.

    2005-01-01

    Use of solvents for the extraction of heavy oil and bitumen appears to be an increasingly feasible technology. Both vapour extraction and direct solvent injection are considered for conventional exploration and production schemes, while solvent dilution of bitumen is a standard technique in oil sands mining. Mass transfer between solvent and bitumen is a poorly understood process. In some cases, it is totally ignored compared to viscous force effects. In other cases, phenomenological estimations of diffusion and dispersion coefficients are used. Low field NMR has been used successfully in determining both solvent content and viscosity reduction in heavy oil and bitumen mixtures with various solvents. As a solvent comes into contact with a heavy oil or bitumen sample, the mobility of hydrogen bearing molecules of both solvent and oil changes. These changes are detectable through changes in the NMR relaxation characteristics of both solvent and oil. Relaxation changes can then be correlated to mass flux and concentration changes. Based on Fick's Second Law, a diffusion coefficient, which is independent of concentration, was calculated against three oils and six solvents. (author)

  15. Effect of cation on diffusion coefficient of ionic liquids at onion-like carbon electrodes.

    Science.gov (United States)

    Van Aken, Katherine L; McDonough, John K; Li, Song; Feng, Guang; Chathoth, Suresh M; Mamontov, Eugene; Fulvio, Pasquale F; Cummings, Peter T; Dai, Sheng; Gogotsi, Yury

    2014-07-16

    While most supercapacitors are limited in their performance by the stability of the electrolyte, using neat ionic liquids (ILs) as the electrolyte can expand the voltage window and temperature range of operation. In this study, ILs with bis(trifluoromethylsulfonyl)imide (Tf2N) as the anion were investigated as the electrolyte in onion-like carbon-based electrochemical capacitors. To probe the influence of cations on the electrochemical performance of supercapacitors, three different cations were used: 1-ethyl-3-methylimidazolium, 1-hexyl-3-methylimidazolium and 1,6-bis(3-methylimidazolium-1-yl). A series of electrochemical characterization tests was performed using cyclic voltammetry (CV), galvanostatic cycling and electrochemical impedance spectroscopy (EIS). Diffusion coefficients were measured using EIS and correlated with quasielastic neutron scattering and molecular dynamics simulation. These three techniques were used in parallel to confirm a consistent trend between the three ILs. It was found that the IL with the smaller sized cation had a larger diffusion coefficient, leading to a higher capacitance at faster charge-discharge rates. Furthermore, the IL electrolyte performance was correlated with increasing temperature, which limited the voltage stability window and led to the formation of a solid electrolyte interphase on the carbon electrode surface, evident in both the CV and EIS experiments.

  16. Experimental investigation of the diffusion coefficients in porous media by application of X-ray computer tomography

    DEFF Research Database (Denmark)

    Zhelezny, Petr; Shapiro, Alexander

    2006-01-01

    is demonstrated. A series of such experiments was carried out. Several samples of carbonaceous and sandstone rock were investigated. The diffusion coefficients in porous media were determined by measuring the concentration of salt in different slices of a sample as a function of time. In cases where stable values...... of diffusion coefficients were obtained (all samples except for one highly heterogeneous sample), these values served for the determination of the tortuosity-porosity factors for a given type of porous medium....

  17. Correlation between 3 T apparent diffusion coefficient values and grading of invasive breast carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Cipolla, Valentina, E-mail: valentina.cipolla@yahoo.it [Department of Radiological Sciences, University of Rome “Sapienza”, Viale del Policlinico 155, 00161 Rome (Italy); Santucci, Domiziana; Guerrieri, Daniele; Drudi, Francesco Maria [Department of Radiological Sciences, University of Rome “Sapienza”, Viale del Policlinico 155, 00161 Rome (Italy); Meggiorini, Maria Letizia [Department of Gynaecological Sciences, University of Rome “Sapienza”, Viale del Policlinico 155, 00161 Rome (Italy); Felice, Carlo de [Department of Radiological Sciences, University of Rome “Sapienza”, Viale del Policlinico 155, 00161 Rome (Italy)

    2014-12-15

    Highlights: • Apparent diffusion coefficient is a quantitative parameter which reflects molecular water movement. • Grading is an independent prognostic factor which correlates with other histopathological features. • Apparent diffusion coefficient values were significantly different between G1 and G3 classes. - Abstract: Purpose: The aim of this study was to evaluate whether the apparent diffusion coefficient (ADC) provided by 3.0 T (3 T) magnetic resonance diffusion-weighted imaging (DWI) varied according to the grading of invasive breast carcinoma. Materials and methods: A total of 92 patients with 96 invasive breast cancer lesions were enrolled; all had undergone 3 T magnetic resonance imaging (MRI) for local staging. All lesions were confirmed by histological analysis, and tumor grade was established according to the Nottingham Grading System (NGS). MRI included both dynamic contrast-enhanced and DWI sequences, and ADC value was calculated for each lesion. ADC values were compared with NGS classification using the Mann–Whitney U and the Kruskal–Wallis H tests. Grading was considered as a comprehensive prognostic factor, and Rho Spearman test was performed to determine correlation between grading and tumor size, hormonal receptor status, HER2 expression and Ki67 index. Pearson's Chi square test was carried out to compare grading with the other prognostic factors. Results: ADC values were significantly higher in G1 than in G3 tumors. No significant difference was observed when G1 and G3 were compared with G2. Tumor size, hormonal receptor status, HER2 expression and Ki67 index correlated significantly with grading but there was a significant difference only between G1 and G3 related to the ER and PR status, HER2 expression and Ki67 index. There was no statistically significant difference in lesion size between the two groups. Conclusion: ADC values obtained on 3 T DWI correlated with low-grade (G1) and high-grade (G3) invasive breast carcinoma. 3

  18. Apparent Diffusion Coefficient (ADC) as a quantitative parameter in diffusion weighted MR imaging in gynecologic cancer: Dependence on b-values used

    DEFF Research Database (Denmark)

    Kallehauge, Jesper Folsted; Tanderup, Kari; Haack, Søren

    2010-01-01

    Diffusion weighted imaging (DWI) has gained interest as an imaging modality for assessment of tumor extension and response to cancer treatment. The purpose of this study is to assess the impact of the choice of b-values on the calculation of the Apparent Diffusion Coefficient (ADC) for locally ad...... advanced gynecological cancer and to estimate a stable interval of diffusion gradients that allows for best comparison of the ADC between patients and institutions....

  19. On a nonlinear degenerate parabolic transport-diffusion equation with a discontinuous coefficient

    Directory of Open Access Journals (Sweden)

    John D. Towers

    2002-10-01

    Full Text Available We study the Cauchy problem for the nonlinear (possibly strongly degenerate parabolic transport-diffusion equation $$ partial_t u + partial_x (gamma(xf(u=partial_x^2 A(u, quad A'(cdotge 0, $$ where the coefficient $gamma(x$ is possibly discontinuous and $f(u$ is genuinely nonlinear, but not necessarily convex or concave. Existence of a weak solution is proved by passing to the limit as $varepsilondownarrow 0$ in a suitable sequence ${u_{varepsilon}}_{varepsilon>0}$ of smooth approximations solving the problem above with the transport flux $gamma(xf(cdot$ replaced by $gamma_{varepsilon}(xf(cdot$ and the diffusion function $A(cdot$ replaced by $A_{varepsilon}(cdot$, where $gamma_{varepsilon}(cdot$ is smooth and $A_{varepsilon}'(cdot>0$. The main technical challenge is to deal with the fact that the total variation $|u_{varepsilon}|_{BV}$ cannot be bounded uniformly in $varepsilon$, and hence one cannot derive directly strong convergence of ${u_{varepsilon}}_{varepsilon>0}$. In the purely hyperbolic case ($A'equiv 0$, where existence has already been established by a number of authors, all existence results to date have used a singular maolinebreak{}pping to overcome the lack of a variation bound. Here we derive instead strong convergence via a series of a priori (energy estimates that allow us to deduce convergence of the diffusion function and use the compensated compactness method to deal with the transport term. Submitted April 29, 2002. Published October 27, 2002. Math Subject Classifications: 35K65, 35D05, 35R05, 35L80 Key Words: Degenerate parabolic equation; nonconvex flux; weak solution; discontinuous coefficient; viscosity method; a priori estimates; compensated compactness

  20. Theory of the diffusion coefficient of neutrons in a lattice containing cavities

    International Nuclear Information System (INIS)

    Benoist, P.

    1964-01-01

    In an previous publication, a simple and general formulation of the diffusion coefficient, which defines the mode of weighting of the mean free paths of the various media, in introducing the collision probabilities in each medium, was established. This expression is demonstrated again here through a more direct method, and the velocity is introduced; new terms are emphasised, the existence of which implies that the representation of the diffusion area as the mean square of the straight line distance from source to absorption is not correct in a lattice. However these terms are of small enough an order of magnitude to he treated as a correction. The general expression also shows the existence, for the radial coefficient, of the series of angular correlation terms, which is seen to converge very slowly for large channels. The term by term computation which was initiated in the first work was then interrupted and a global formulation, which emphasize a resemblance with the problem of the thermal utilisation factor, was adopted. An integral method, analogous to that use for the computation of this factor, gives the possibility to establish new and simple practical formulae, which require the use of a few basic functions only. These formulae are very accurate, as seen from the results of a variational method which was studied as a reference. Various correction effects are reviewed. Expressions which allow the exact treatment of fuel rod clusters are presented. The theory is confronted with various experimental results, and a new method of measuring the radial coefficient is proposed. (author) [fr

  1. Diffusion coefficients of nickel chloride in aqueous solutions of lactose at T = 298.15 K and T = 310.15 K

    Energy Technology Data Exchange (ETDEWEB)

    Ribeiro, Ana C.F., E-mail: anacfrib@ci.uc.p [Department of Chemistry, University of Coimbra, 3004-535 Coimbra (Portugal); Gomes, Joselaine C.S., E-mail: leidygomes18@hotmail.co [Department of Chemistry, University of Coimbra, 3004-535 Coimbra (Portugal); Barros, Marisa C.F., E-mail: marisa.barros@gmail.co [Department of Chemistry, University of Coimbra, 3004-535 Coimbra (Portugal); Lobo, Victor M.M., E-mail: vlobo@ci.uc.p [Department of Chemistry, University of Coimbra, 3004-535 Coimbra (Portugal); Esteso, Miguel A., E-mail: miguel.esteso@uah.e [Departamento de Quimica Fisica, Facultad de Farmacia, Universidad de Alcala, 28871, Alcala de Henares (Madrid) (Spain)

    2011-03-15

    Binary mutual diffusion coefficients (interdiffusion coefficients) of nickel chloride in water at T = 298.15 K and T = 310.15 K, and at concentrations between (0.000 and 0.100) mol {center_dot} dm{sup -3}, using a Taylor dispersion method have been measured. These data are discussed on the basis of the Onsager-Fuoss and Pikal models. The equivalent conductance at infinitesimal concentration of the nickel ion in these solutions at T = 310.15 K has been estimated using these results. Through the same technique, ternary mutual diffusion coefficients (D{sub 11}, D{sub 22}, D{sub 12}, and D{sub 21}) for aqueous solutions containing NiCl{sub 2} and lactose, at T = 298.15 K and T = 310.15 K, and at different carrier concentrations were also measured. These data permit us to have a better understanding of the structure of these systems and the thermodynamic behaviour of NiCl{sub 2} in different media.

  2. Relationship between apparent diffusion coefficients at 3.0-T MR imaging and Gleason grade in peripheral zone prostate cancer

    NARCIS (Netherlands)

    Hambrock, T.; Somford, D.M.; Huisman, H.J.; Oort, I.M. van; Witjes, J.A.; Hulsbergen-van de Kaa, C.A.; Scheenen, T.W.J.; Barentsz, J.O.

    2011-01-01

    PURPOSE: To retrospectively determine the relationship between apparent diffusion coefficients (ADCs) obtained with 3.0-T diffusion-weighted (DW) magnetic resonance (MR) imaging and Gleason grades in peripheral zone prostate cancer. MATERIALS AND METHODS: The requirement to obtain institutional

  3. Simultaneous free-volume modeling of the self-diffusion coefficient and dynamic viscosity at high pressure

    DEFF Research Database (Denmark)

    Boned, C.; Allal, A.; Baylaucq, A.

    2004-01-01

    In this work, a simultaneous modeling of the self-diffusion coefficient and the dynamic viscosity is presented. In the microstructural theory these two quantities are governed by the same friction coefficient related to the mobility of the molecule. A recent free-volume model, already successfully...

  4. Mass transfer of SCWO processes: Molecular diffusion and mass transfer coefficients of inorganic nitrate species in sub- and supercritical water

    Energy Technology Data Exchange (ETDEWEB)

    Goemans, M.G.E.; Gloyna, E.F. [Univ. of Texas, Austin, TX (United States). Dept. of Civil Engineering; Buelow, S.J. [Los Alamos National Lab., NM (United States)

    1996-04-01

    Molecular diffusion coefficients of lithium-, sodium-, potassium-, cesium-, calcium-, and strontium nitrate in subcritical water were determined by analysis of Taylor dispersion profiles. Pressures ranged from 300 to 500 bar at temperatures ranging from 25{degrees}C to 300{degrees}C. The reported diffusion values were determined at infinite dilution. Molecular diffusion coefficients were 10 to 20 times faster in near-critical subcritical water than in water at ambient temperature and pressure (ATP). These findings implied that the diffusion rates were more liquid like than they were gas like, hence experimental results were correlated with diffusion models for liquids. The subcritical diffusion data presented in this work, and supercritical diffusion results published elsewhere were correlated with hydrodynamic diffusion equations. Both the Wilke-Chang correlation and the Stokes-Einstein equation yielded predictions within 10% of the experimental results if the structure of the diffusing species could be estimated. The effect of the increased diffusion rates on mass transfer rates in supercritical water oxidation applications was quantified, with emphasis on heterogeneous oxidation processes. This study and results published elsewhere showed that diffusion limited conditions are much more likely to be encountered in SCWO processes than commonly acknowledged.

  5. Apparent diffusion coefficient histogram analysis of neonatal hypoxic-ischemic encephalopathy

    Energy Technology Data Exchange (ETDEWEB)

    Cauley, Keith A. [University of Massachusetts Medical School, Department of Radiology, Worcester, MA (United States); New York Presbyterian Hospital, Columbia University Medical Center, Department of Radiology, New York, NY (United States); Filippi, Christopher G. [New York Presbyterian Hospital, Columbia University Medical Center, Department of Radiology, New York, NY (United States)

    2014-06-15

    Diffusion-weighted imaging is a valuable tool in the assessment of the neonatal brain, and changes in diffusion are seen in normal development as well as in pathological states such as hypoxic-ischemic encephalopathy (HIE). Various methods of quantitative assessment of diffusion values have been reported. Global ischemic injury occurring during the time of rapid developmental changes in brain myelination can complicate the imaging diagnosis of neonatal HIE. To compare a quantitative method of histographic analysis of brain apparent coefficient (ADC) maps to the qualitative interpretation of routine brain MR imaging studies. We correlate changes in diffusion values with gestational age in radiographically normal neonates, and we investigate the sensitivity of the method as a quantitative measure of hypoxic-ischemic encephalopathy. We reviewed all brain MRI studies from the neonatal intensive care unit (NICU) at our university medical center over a 4-year period to identify cases that were radiographically normal (23 cases) and those with diffuse, global hypoxic-ischemic encephalopathy (12 cases). We histographically displayed ADC values of a single brain slice at the level of the basal ganglia and correlated peak (s-sD{sub av}) and lowest histogram values (s-sD{sub lowest}) with gestational age. Normative s-sD{sub av} values correlated significantly with gestational age and declined linearly through the neonatal period (r {sup 2} = 0.477, P < 0.01). Six of 12 cases of known HIE demonstrated significantly lower s-sD{sub av} and s-sD{sub lowest} ADC values than were reflected in the normative distribution; several cases of HIE fell within a 95% confidence interval for normative studies, and one case demonstrated higher-than-normal s-sD{sub av}. Single-slice histographic display of ADC values is a rapid and clinically feasible method of quantitative analysis of diffusion. In this study normative values derived from consecutive neonates without radiographic evidence of

  6. Relationships between brain water content and diffusion tensor imaging parameters (apparent diffusion coefficient and fractional anisotropy) in multiple sclerosis

    International Nuclear Information System (INIS)

    Sijens, Paul E.; Irwan, Roy; Potze, Jan Hendrik; Oudkerk, Matthijs; Mostert, Jop P.; Keyser, Jacques de

    2006-01-01

    Fifteen multiple sclerosis patients were examined by diffusion tensor imaging (DTI) to determine fractional anisotropy (FA) and apparent diffusion coefficient (ADC) in a superventricular volume of interest of 8 x 8 x 2 cm 3 containing gray matter (GM) and white matter (WM) tissue. Point resolved spectroscopy 2D-chemical shift imaging of the same volume was performed without water suppression. The water contents and DTI parameters in 64 voxels of 2 cm 3 were compared. The water content was increased in patients compared with controls (GM: 244±21 vs. 194±10 a.u.; WM: 245±32 vs. 190±11 a.u.), FA decreased (GM: 0.226±0.038 vs. 0.270±0.020; WM: 0.337±0.044 vs. 0.402±0.011) and ADC increased [GM: 1134±203 vs. 899±28 (x 10 -6 mm 2 /s); WM: 901±138 vs. 751±17 (x 10 -6 mm 2 /s)]. Correlations of water content with FA and ADC in WM were strong (r=-0.68, P<0.02; r=0.75; P<0.01, respectively); those in GM were weaker (r=-0.50, P<0.05; r=0.45, P<0.1, respectively). Likewise, FA and ADC were more strongly correlated in WM (r=-0.88; P<0.00001) than in GM (r=-0.69, P<0.01). The demonstrated relationship between DTI parameters and water content in multiple sclerosis patients suggests a potential for therapy monitoring in normal-appearing brain tissue. (orig.)

  7. Apparent diffusion coefficient value of gastric cancer by diffusion-weighted imaging: Correlations with the histological differentiation and Lauren classification

    International Nuclear Information System (INIS)

    Liu, Song; Guan, Wenxian; Wang, Hao; Pan, Liang; Zhou, Zhuping; Yu, Haiping; Liu, Tian; Yang, Xiaofeng; He, Jian; Zhou, Zhengyang

    2014-01-01

    Highlights: • Gastric cancers’ ADC values were significantly lower than normal gastric wall. • Gastric adenocarcinomas with different differentiation had different ADC values. • Gastric adenocarcinomas’ ADC values correlated with histologic differentiations. • Gastric cancers’ ADC values correlated with Lauren classifications. • Mean ADC value was better than min ADC value in characterizing gastric cancers. - Abstract: Objective: The purpose of this study was to evaluate the correlations between histological differentiation and Lauren classification of gastric cancer and the apparent diffusion coefficient (ADC) value of diffusion weighted imaging (DWI). Materials and methods: Sixty-nine patients with gastric cancer lesions underwent preoperative magnetic resonance imaging (MRI) (3.0T) and surgical resection. DWI was obtained with a single-shot, echo-planar imaging sequence in the axial plane (b values: 0 and 1000 s/mm 2 ). Mean and minimum ADC values were obtained for each gastric cancer and normal gastric walls by two radiologists, who were blinded to the histological findings. Histological type, degree of differentiation and Lauren classification of each resected specimen were determined by one pathologist. Mean and minimum ADC values of gastric cancers with different histological types, degrees of differentiation and Lauren classifications were compared. Correlations between ADC values and histological differentiation and Lauren classification were analyzed. Results: The mean and minimum ADC values of gastric cancers, as a whole and separately, were significantly lower than those of normal gastric walls (all p values <0.001). There were significant differences in the mean and minimum ADC values among gastric cancers with different histological types, degrees of differentiation and Lauren classifications (p < 0.05). Mean and minimum ADC values correlated significantly (all p < 0.001) with histological differentiation (r = 0.564, 0.578) and Lauren

  8. Role of PROPELLER diffusion weighted imaging and apparent diffusion coefficient in the diagnosis of sellar and parasellar lesions

    International Nuclear Information System (INIS)

    Mahmoud, Omar M.; Tominaga, Atsushi; Amatya, Vishwa Jeet; Ohtaki, Megu; Sugiyama, Kazuhiko; Saito, Taiichi; Sakoguchi, Tetsuhiko; Kinoshita, Yasuyuki; Shrestha, Prabin; Abe, Nobukazu

    2010-01-01

    Objective: To evaluate the role of the apparent diffusion coefficient (ADC) using periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) diffusion weighted imaging (DWI) in the differentiation between sellar and parasellar mass lesions. Materials and methods: The study protocol was approved by our institutional review board. We retrospectively studied 60 patients with sellar and parasellar lesions who had undergone PROPELLER DWI on a 3-T MR imager. Conventional MRI findings were expressed as the ratio of signal intensity (SI) in the lesions to the normal white matter and the degree of contrast enhancement. ADC values were calculated as the minimum (ADC-MIN), mean (ADC-MEAN), and maximum (ADC-MAX). All patients underwent surgery and all specimens were examined histologically. Logistic discriminant analysis was performed by using the SI ratios on T1- and T2-weighted images (T1-WI, T2-WI), the degree of enhancement, and absolute ADC values as independent variables. Results: ADC-MIN of hemorrhagic pituitary adenomas was lower than of the other lesions with similar appearance on conventional MRI (non-hemorrhagic pituitary adenomas, craniopharyngiomas, Rathke's cleft cysts; accuracy 100%); the useful cut-off value was 0.700 x 10 -3 mm 2 /s. ADC-MAX of meningiomas was lower than of non-hemorrhagic pituitary adenomas (accuracy 90.3%; p < 0.01). ADC-MIN of craniopharyngiomas was lower than of Rathke's cleft cysts (accuracy 100%; p < 0.05). Conclusion: As PROPELLER DWI is less sensitive to susceptibility artifacts than single-shot echoplanar DWI, it is more useful in the examination of sellar and parasellar lesions. Calculation of the ADC values helps to differentiate between various sellar and parasellar lesions.

  9. Apparent diffusion coefficient value of gastric cancer by diffusion-weighted imaging: Correlations with the histological differentiation and Lauren classification

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Song, E-mail: songliu532909756@gmail.com [Department of Radiology, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing 210008 (China); Guan, Wenxian, E-mail: wenxianguan123@126.com [Department of Gastrointestinal Surgery, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing 210008 (China); Wang, Hao, E-mail: wanghao20140525@126.com [Department of Gastrointestinal Surgery, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing 210008 (China); Pan, Liang, E-mail: panliang2014@126.com [Department of Radiology, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing 210008 (China); Zhou, Zhuping, E-mail: zhupingzhou@126.com [Department of Radiology, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing 210008 (China); Yu, Haiping, E-mail: haipingyu2012@126.com [Department of Radiology, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing 210008 (China); Liu, Tian, E-mail: tianliu2014@126.com [Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30322 (United States); Yang, Xiaofeng, E-mail: xiaofengyang2014@126.com [Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30322 (United States); He, Jian, E-mail: hjxueren@126.com [Department of Radiology, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing 210008 (China); Zhou, Zhengyang, E-mail: zyzhou@nju.edu.cn [Department of Radiology, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing 210008 (China)

    2014-12-15

    Highlights: • Gastric cancers’ ADC values were significantly lower than normal gastric wall. • Gastric adenocarcinomas with different differentiation had different ADC values. • Gastric adenocarcinomas’ ADC values correlated with histologic differentiations. • Gastric cancers’ ADC values correlated with Lauren classifications. • Mean ADC value was better than min ADC value in characterizing gastric cancers. - Abstract: Objective: The purpose of this study was to evaluate the correlations between histological differentiation and Lauren classification of gastric cancer and the apparent diffusion coefficient (ADC) value of diffusion weighted imaging (DWI). Materials and methods: Sixty-nine patients with gastric cancer lesions underwent preoperative magnetic resonance imaging (MRI) (3.0T) and surgical resection. DWI was obtained with a single-shot, echo-planar imaging sequence in the axial plane (b values: 0 and 1000 s/mm{sup 2}). Mean and minimum ADC values were obtained for each gastric cancer and normal gastric walls by two radiologists, who were blinded to the histological findings. Histological type, degree of differentiation and Lauren classification of each resected specimen were determined by one pathologist. Mean and minimum ADC values of gastric cancers with different histological types, degrees of differentiation and Lauren classifications were compared. Correlations between ADC values and histological differentiation and Lauren classification were analyzed. Results: The mean and minimum ADC values of gastric cancers, as a whole and separately, were significantly lower than those of normal gastric walls (all p values <0.001). There were significant differences in the mean and minimum ADC values among gastric cancers with different histological types, degrees of differentiation and Lauren classifications (p < 0.05). Mean and minimum ADC values correlated significantly (all p < 0.001) with histological differentiation (r = 0.564, 0.578) and

  10. Effect of confining pressure on diffusion coefficients in clay-rich, low-permeability sedimentary rocks.

    Science.gov (United States)

    Xiang, Y; Al, T; Mazurek, M

    2016-12-01

    The effect of confining pressure (CP) on the diffusion of tritiated-water (HTO) and iodide (I - ) tracers through Ordovician rocks from the Michigan Basin, southwestern Ontario, Canada, and Opalinus Clay from Schlattingen, Switzerland was investigated in laboratory experiments. Four samples representing different formations and lithologies in the Michigan Basin were studied: Queenston Formation shale, Georgian Bay Formation shale, Cobourg Formation limestone and Cobourg Formation argillaceous limestone. Estimated in situ vertical stresses at the depths from which the samples were retrieved range from 12.0 to 17.4MPa (Michigan Basin) and from 21 to 23MPa (Opalinus Clay). Effective diffusion coefficients (D e ) were determined in through-diffusion experiments. With HTO tracer, applying CP resulted in decreases in D e of 12.5% for the Queenston Formation shale (CP max =12MPa), 30% for the Georgian Bay Formation shale (15MPa), 34% for the Cobourg Formation limestone (17.4MPa), 31% for the Cobourg Formation argillaceous limestone (17.4MPa) and 43-46% for the Opalinus Clay (15MPa). Decreases in D e were larger for the I - tracer: 13.8% for the Queenston shale, 42% for the Georgian Bay shale, 50% for the Cobourg Formation limestone, 55% for the Cobourg Formation argillaceous limestone and 63-68% for the Opalinus Clay. The tracer-specific nature of the response is attributed to an increasing influence of anion exclusion as the pore size decreases at higher CP. Results from the shales (including Opalinus Clay) indicate that the pressure effect on D e can be represented by a linear relationship between D e and ln(CP), which provides valuable predictive capability. The nonlinearity results in a relatively small change in D e at high CP, suggesting that it is not necessary to apply the exact in situ pressure conditions in order to obtain a good estimate of the in situ diffusion coefficient. Most importantly, the CP effect on shale is reversible (±12%) suggesting that, for

  11. Measurement of the Diffusion Coefficient of Water in RP-3 and RP-5 Jet Fuels Using Digital Holography Interferometry

    Science.gov (United States)

    Li, Chaoyue; Feng, Shiyu; Shao, Lei; Pan, Jun; Liu, Weihua

    2018-04-01

    The diffusion coefficient of water in jet fuel was measured employing double-exposure digital holographic interferometry to clarify the diffusion process and make the aircraft fuel system safe. The experimental method and apparatus are introduced in detail, and the digital image processing program is coded in MATLAB according to the theory of the Fourier transform. At temperatures ranging from 278.15 K to 333.15 K in intervals of 5 K, the diffusion coefficient of water in RP-3 and RP-5 jet fuels ranges from 2.6967 × 10 -10 m2·s-1 to 8.7332 × 10 -10 m2·s-1 and from 2.3517 × 10 -10 m2·s-1 to 8.0099 × 10-10 m2·s-1, respectively. The relationship between the measured diffusion coefficient and temperature can be well fitted by the Arrhenius law. The diffusion coefficient of water in RP-3 jet fuel is higher than that of water in RP-5 jet fuel at the same temperature. Furthermore, the viscosities of the two jet fuels were measured and found to be expressible in the form of the Arrhenius equation. The relationship among the diffusion coefficient, viscosity and temperature is analyzed according to the classic prediction model, namely the Stokes-Einstein correlation, and this correlation is further revised via experimental data to obtain a more accurate predication result.

  12. Computer simulations of adsorption and diffusion for binary mixtures of methane and hydrogen in titanosilicates

    Science.gov (United States)

    Mitchell, Martha C.; Gallo, Marco; Nenoff, Tina M.

    2004-07-01

    Equilibrium molecular dynamics (MD) simulations of equimolar mixtures of hydrogen and methane were performed in three different titanosilicates: naturally occurring zorite and two synthetic titanosilicates, ETS-4 and ETS-10. In addition, single-component MD simulations and adsorption isotherms generated using grand canonical Monte Carlo simulations were performed to support the mixture simulations. The goal of this study was to determine the best membrane material to carry out hydrogen/methane separations. ETS-10 has a three-dimensional pore network. ETS-4 and zorite have two-dimensional pore networks. The simulations carried out in this study show that the increased porosity of ETS-10 results in self-diffusion coefficients for both hydrogen and methane that are higher in ETS-10 than in either ETS-4 or zorite. Methane only showed appreciable displacement in ETS-10. The ability of the methane molecules to move in all three directions in ETS-10 was demonstrated by the high degree of isotropy shown in the values of the x, y, and z components of the self-diffusion coefficient for methane in ETS-10. From our simulations we conclude that ETS-10 would be better suited for fast industrial separations of hydrogen and methane. However, the separation would not result in a pure hydrogen stream. In contrast, ETS-4 and zorite would act as true molecular sieves for separations of hydrogen and methane, as the methane would not move through membranes made of these materials. This was indicated by the near-zero self-diffusion coefficient of methane in ETS-4 and zorite.

  13. Easy measurement of diffusion coefficients of EGFP-tagged plasma membrane proteins using k-space Image Correlation Spectroscopy

    DEFF Research Database (Denmark)

    Christensen, Eva Arnspang; Koffman, Jennifer Skaarup; Marlar, Saw

    2014-01-01

    Lateral diffusion and compartmentalization of plasma membrane proteins are tightly regulated in cells and thus, studying these processes will reveal new insights to plasma membrane protein function and regulation. Recently, k-Space Image Correlation Spectroscopy (kICS)1 was developed to enable...... routine measurements of diffusion coefficients directly from images of fluorescently tagged plasma membrane proteins, that avoided systematic biases introduced by probe photophysics. Although the theoretical basis for the analysis is complex, the method can be implemented by nonexperts using a freely...... to the correlation function yields the diffusion coefficient. This paper provides a step-by-step guide to the image analysis and measurement of diffusion coefficients via kICS. First, a high frame rate image sequence of a fluorescently labeled plasma membrane protein is acquired using a fluorescence microscope Then...

  14. Optimal Experiment Design for Monoexponential Model Fitting: Application to Apparent Diffusion Coefficient Imaging.

    Science.gov (United States)

    Alipoor, Mohammad; Maier, Stephan E; Gu, Irene Yu-Hua; Mehnert, Andrew; Kahl, Fredrik

    2015-01-01

    The monoexponential model is widely used in quantitative biomedical imaging. Notable applications include apparent diffusion coefficient (ADC) imaging and pharmacokinetics. The application of ADC imaging to the detection of malignant tissue has in turn prompted several studies concerning optimal experiment design for monoexponential model fitting. In this paper, we propose a new experiment design method that is based on minimizing the determinant of the covariance matrix of the estimated parameters (D-optimal design). In contrast to previous methods, D-optimal design is independent of the imaged quantities. Applying this method to ADC imaging, we demonstrate its steady performance for the whole range of input variables (imaged parameters, number of measurements, and range of b-values). Using Monte Carlo simulations we show that the D-optimal design outperforms existing experiment design methods in terms of accuracy and precision of the estimated parameters.

  15. Vapour pressures, osmotic and activity coefficients for binary mixtures containing (1-ethylpyridinium ethylsulfate + several alcohols) at T = 323.15 K

    International Nuclear Information System (INIS)

    Calvar, Noelia; Gomez, Elena; Dominguez, Angeles; Macedo, Eugenia A.

    2010-01-01

    Osmotic coefficients of binary mixtures containing several primary and secondary alcohols (1-propanol, 2-propanol, 1-butanol, 2-butanol, and 1-pentanol) and the pyridinium-based ionic liquid 1-ethylpyridinium ethylsulfate were determined at T = 323.15 K using the vapour pressure osmometry technique. From the experimental results, vapour pressure and activity coefficients can be determined. For the correlation of osmotic coefficients, the extended Pitzer model modified by Archer, and the modified NRTL (MNRTL) model were used, obtaining deviations lower than 0.017 and 0.047, respectively. The mean molal activity coefficients and the excess Gibbs free energy for the binary mixtures studied were determined from the parameters obtained with the extended Pitzer model modified by Archer.

  16. Impact of post-processing methods on apparent diffusion coefficient values

    Energy Technology Data Exchange (ETDEWEB)

    Zeilinger, Martin Georg; Lell, Michael; Uder, Michael [University of Erlangen-Nuremberg, Institute of Diagnostic Radiology, Erlangen (Germany); Baltzer, Pascal Andreas Thomas [Medical University Vienna, Department of Radiology and Nuclear Medicine, Vienna (Austria); Doerfler, Arnd; Dietzel, Matthias [University of Erlangen-Nuremberg, Department of Neuroradiology, Erlangen (Germany)

    2017-03-15

    The apparent diffusion coefficient (ADC) is increasingly used as a quantitative biomarker in oncological imaging. ADC calculation is based on raw diffusion-weighted imaging (DWI) data, and multiple post-processing methods (PPMs) have been proposed for this purpose. We investigated whether PPM has an impact on final ADC values. Sixty-five lesions scanned with a standardized whole-body DWI-protocol at 3 T served as input data (EPI-DWI, b-values: 50, 400 and 800 s/mm{sup 2}). Using exactly the same ROI coordinates, four different PPM (ADC{sub 1}-ADC{sub 4}) were executed to calculate corresponding ADC values, given as [10{sup -3} mm{sup 2}/s] of each lesion. Statistical analysis was performed to intra-individually compare ADC values stratified by PPM (Wilcoxon signed-rank tests: α = 1 %; descriptive statistics; relative difference/∇; coefficient of variation/CV). Stratified by PPM, mean ADCs ranged from 1.136-1.206 *10{sup -3} mm{sup 2}/s (∇ = 7.0 %). Variances between PPM were pronounced in the upper range of ADC values (maximum: 2.540-2.763 10{sup -3} mm{sup 2}/s, ∇ = 8 %). Pairwise comparisons identified significant differences between all PPM (P ≤ 0.003; mean CV = 7.2 %) and reached 0.137 *10{sup -3} mm{sup 2}/s within the 25th-75th percentile. Altering the PPM had a significant impact on the ADC value. This should be considered if ADC values from different post-processing methods are compared in patient studies. (orig.)

  17. Apparent Diffusion Coefficient Measurement in Mediastinal Lymphadenopathies: Differentiation between Benign and Malignant Lesions

    Directory of Open Access Journals (Sweden)

    Fethi Emre Ustabasioglu

    2017-01-01

    Full Text Available Objectives: We aimed to prospectively assess the diagnostic value of apparent diffusion coefficient (ADC measurement in the differentiation of benign and malignant mediastinal lymphadenopathies. Materials and Methods: The study included 63 consecutive patients (28 women, 35 men; mean age 59.3 years with 125 mediastinal lymphadenopathies. Echoplanar diffusion-weighted magnetic resonance imaging of the mediastinum was performed with b-factors of 0 and 600 mm2/s before mediastinoscopy and mediastinotomy, and ADC values were measured. The ADC values were compared with the histological results, and statistical analysis was done. P < 0.05 was considered statistically significant. Results: The mean ADC value of malignant mediastinal lymphadenopathy (1.030 ± 0.245 × 10−3 mm2/s was significantly lower (P < 0.05 when compared to benign lymphadenopathies (1.571 ± 0.559 × 10−3 mm2/s. For differentiating malignant from benign mediastinal lymphadenopathy, the best result was obtained when an ADC value of 1.334 × 10−3 mm2/s was used as a threshold value; area under the curve 0.848, accuracy 78.4%, sensitivity 66%, specificity of 86%, positive predictive value 76.7%, and negative predictive value of 79.2%. Interobserver agreement was excellent for ADC measurements. Conclusions: ADC measurements could be considered an important supportive method in differentiating benign from malignant mediastinal lymphadenopathies.

  18. Regional apparent diffusion coefficient values in 3rd trimester fetal brain

    Energy Technology Data Exchange (ETDEWEB)

    Hoffmann, Chen [Tel Aviv University, Department of Radiology, Sheba Medical Center, Tel Hashomer (affiliated to the Sackler School of Medicine), Tel Aviv (Israel); Sheba Medical Center, Diagnostic Imaging, 52621, Tel Hashomer (Israel); Weisz, Boaz; Lipitz, Shlomo; Katorza, Eldad [Tel Aviv University, Department of Obstetrics and Gynecology, Sheba Medical Center, Tel Hashomer (affiliated to the Sackler School of Medicine), Tel Aviv (Israel); Yaniv, Gal; Bergman, Dafi [Tel Aviv University, Department of Radiology, Sheba Medical Center, Tel Hashomer (affiliated to the Sackler School of Medicine), Tel Aviv (Israel); Biegon, Anat [Stony Brook University School of Medicine, Department of Neurology, Stony Brook, NY (United States)

    2014-07-15

    Apparent diffusion coefficient (ADC) values in the developing fetus can be used in the diagnosis and prognosis of prenatal brain pathologies. To this end, we measured regional ADC in a relatively large cohort of normal fetal brains in utero. Diffusion-weighted imaging (DWI) was performed in 48 non-sedated 3rd trimester fetuses with normal structural MR imaging results. ADC was measured in white matter (frontal, parietal, temporal, and occipital lobes), basal ganglia, thalamus, pons, and cerebellum. Regional ADC values were compared by one-way ANOVA with gestational age as covariate. Regression analysis was used to examine gestational age-related changes in regional ADC. Four other cases of CMV infection were also examined. Median gestational age was 32 weeks (range, 26-33 weeks). There was a highly significant effect of region on ADC, whereby ADC values were highest in white matter, with significantly lower values in basal ganglia and cerebellum and the lowest values in thalamus and pons. ADC did not significantly change with gestational age in any of the regions tested. In the four cases with fetal CMV infection, ADC value was associated with a global decrease. ADC values in normal fetal brain are relatively stable during the third trimester, show consistent regional variation, and can make an important contribution to the early diagnosis and possibly prognosis of fetal brain pathologies. (orig.)

  19. Measurement of ageing effect on chloride diffusion coefficients in cementitious matrices

    International Nuclear Information System (INIS)

    Andrade, C.; Castellote, M.; D'Andrea, R.

    2011-01-01

    Most of the low-level nuclear waste disposal facilities are based in engineered multi barrier systems where reinforced concrete is one of the basic materials. The calculation of the time until steel reinforcement depassivation is a need due to the demand of prediction of the service life of concrete structures in radioactive repositories. In doing that, one of the main steps is the transport of chloride ions towards the reinforcement, as one of the most aggressive agents for the rebars in concrete is chloride ions. Ageing of concrete related to chloride penetration leads to significant decrease of the 'apparent diffusion' coefficient with time. If this effect is not considered, considerable bias can be introduced when predicting service life of reinforced concrete of repositories. Several effects have been addressed on their influence on the ageing of concrete, including the evolution with time of the concrete pore refinement, the binding of chlorides to the cement phases and to the changes of chloride 'surface concentration'. These effects have been studied in specimens made with different mixes trying to represent a wide range of mineral addition proportions. The analysis of their evolution with time has shown that the resistivity alone or the joint consideration of resistivity and binding capacity (C b /C f ), are appropriate parameters to appraise the diffusivity ageing. For practical reasons, an accelerated procedure is proposed in order to calculate ageing for short periods of time.

  20. Apparent diffusion coefficient in cervical cancer of the uterus: comparison with the normal uterine cervix

    International Nuclear Information System (INIS)

    Naganawa, Shinji; Sato, Chiho; Ishigaki, Takeo; Kumada, Hisashi; Miura, Shunichi; Takizawa, Osamu

    2005-01-01

    A relation between apparent diffusion coefficient (ADC) values and tumor cellular density has been reported. The purpose of this study was to measure the ADC values of cervical cancers in the uterus and compare them with those of normal cervical tissues, and to test whether ADC could differentiate between normal and malignant cervical tissues in the uterus. Twelve consecutive female patients with cervical cancer of the uterus and ten female patients with other pelvic abnormalities were included in this study. ADC was measured at 1.5 T with b-factors of 0, 300 and 600 s/mm 2 using single-shot echo-planar diffusion-weighted imaging and a parallel imaging technique. The mean ADC value of cervical cancer lesions was 1.09±0.20 x 10 -3 mm 2 /s, and that of normal cervix tissue was 1.79±0.24 x 10 -3 mm 2 /s (P<0.0001). In nine patients treated by chemotherapy and/or radiation therapy, the mean ADC value of the cervical cancer lesion increased significantly after therapy (P<0.001). The present study showed, with a small number of patients, that ADC measurement has a potential ability to differentiate between normal and cancerous tissue in the uterine cervix. Further study is necessary to determine the accuracy of ADC measurement in monitoring the treatment response. (orig.)

  1. Regional apparent diffusion coefficient values in 3rd trimester fetal brain

    International Nuclear Information System (INIS)

    Hoffmann, Chen; Weisz, Boaz; Lipitz, Shlomo; Katorza, Eldad; Yaniv, Gal; Bergman, Dafi; Biegon, Anat

    2014-01-01

    Apparent diffusion coefficient (ADC) values in the developing fetus can be used in the diagnosis and prognosis of prenatal brain pathologies. To this end, we measured regional ADC in a relatively large cohort of normal fetal brains in utero. Diffusion-weighted imaging (DWI) was performed in 48 non-sedated 3rd trimester fetuses with normal structural MR imaging results. ADC was measured in white matter (frontal, parietal, temporal, and occipital lobes), basal ganglia, thalamus, pons, and cerebellum. Regional ADC values were compared by one-way ANOVA with gestational age as covariate. Regression analysis was used to examine gestational age-related changes in regional ADC. Four other cases of CMV infection were also examined. Median gestational age was 32 weeks (range, 26-33 weeks). There was a highly significant effect of region on ADC, whereby ADC values were highest in white matter, with significantly lower values in basal ganglia and cerebellum and the lowest values in thalamus and pons. ADC did not significantly change with gestational age in any of the regions tested. In the four cases with fetal CMV infection, ADC value was associated with a global decrease. ADC values in normal fetal brain are relatively stable during the third trimester, show consistent regional variation, and can make an important contribution to the early diagnosis and possibly prognosis of fetal brain pathologies. (orig.)

  2. Value of apparent diffusion coefficient measurement for discrimination of focal benign and malignant hepatic masses.

    Science.gov (United States)

    Kilickesmez, O; Bayramoglu, S; Inci, E; Cimilli, T

    2009-02-01

    The purpose of our study was to investigate the value of diffusion-weighted magnetic resonance imaging (DW-MRI) to discriminate benign and malignant focal lesions of the liver using parallel imaging technique. A total of 77 patients and 65 healthy controls were enrolled in the study. DW-MRI was performed with b-factors of 0, 500 and 1000 s/mm(2), and the apparent diffusion coefficients (ADC) values of the normal liver and the lesions were calculated. The mean ADC value of the focal liver lesions were as follows: simple cysts (3.16 +/- 0.18 x 10(-3) mm(2)/s), hydatid cysts (2.58 +/- 0.53 x 10(-3) mm(2)/s), hemangiomas (1.97 +/- 0.49 x 10(-3) mm(2)/s), metastases (1.14 +/- 0.41 x 10(-3) mm(2)/s) and hepatocellular carcinomas (HCC) (1.15 +/- 0.36 x 10(-3) mm(2)/s). The mean ADC values of all the disease groups were statistically significant when compared with the mean ADC value of the normal liver (1.56 +/- 0.14 x 10(-3) mm(2)/s), (P values of hemangiomas and HCC metastases (P present study showed that ADC measurement has the potential to differentiate benign and malignant focal hepatic lesions. We propose to add DW sequence in the MR protocol for the detection and quantitative discrimination of hepatic pathologies.

  3. Apparent diffusion coefficient values of the normal uterus: Interindividual variations during menstrual cycle

    Energy Technology Data Exchange (ETDEWEB)

    Tsili, A.C., E-mail: a_tsili@yahoo.gr [Department of Clinical Radiology, University Hospital of Ioannina (Greece); Argyropoulou, M.I., E-mail: margyrop@cc.uoi.gr [Department of Clinical Radiology, University Hospital of Ioannina (Greece); Tzarouchi, L., E-mail: ltzar@cc.uoi.gr [Department of Clinical Radiology, University Hospital of Ioannina (Greece); Dalkalitsis, N., E-mail: ndalkal@cc.uoi.gr [Department of Obstetrics and Gynaecology, University Hospital of Ioannina (Greece); Koliopoulos, G., E-mail: georgekoliopoulos@yahoo.com [Department of Obstetrics and Gynaecology, University Hospital of Ioannina (Greece); Paraskevaidis, E., E-mail: eparaske@cc.uoi.gr [Department of Obstetrics and Gynaecology, University Hospital of Ioannina (Greece); Tsampoulas, K., E-mail: ctsampou@uoi.gr [Department of Clinical Radiology, University Hospital of Ioannina (Greece)

    2012-08-15

    Objectives: To assess the apparent diffusion coefficient (ADC) changes of the normal uterine zones among reproductive women during the menstrual cycle. Methods: The study included 101 women of reproductive age, each with regular cycle and normal endometrium/myometrium, as proved on histopathology or MR imaging examination. Diffusion-weighted (DW) imaging was performed along the axial plane, using a single shot, multi-slice spin-echo planar diffusion pulse sequence and b-values of 0 and 800 s/mm{sup 2}. The mean and standard deviation of the ADC values of normal endometrium/myometrium were calculated for menstrual, proliferative and secretory phase. Analysis of variance followed by the least significant difference test was used for statistical analysis. Results: The ADC values of the endometrium were different in the three phases of the menstrual cycle (menstrual phase: 1.25 {+-} 0.27; proliferative phase: 1.39 {+-} 0.20; secretory phase: 1.50 {+-} 0.18) (F: 9.64, p: 0.00). Statistical significant difference was observed among all groups (p < 0.05). The ADC values of the normal myometrium were different in the three phases of the menstrual cycle (menstrual phase: 1.91 {+-} 0.35; proliferative phase: 1.72 {+-} 0.27; secretory phase: 1.87 {+-} 0.28) (F: 3.60, p: 0.03). Statistical significant difference was observed between menstrual and proliferative phase and between proliferative and secretory phase (p < 0.05). No significant difference was noted between menstrual and secretory phase (p > 0.05). Conclusions: A wide variation of ADC values of normal endometrium and myometrium is observed during different phases of the menstrual cycle.

  4. Serial analysis of the apparent diffusion coefficient time course in human stroke

    Energy Technology Data Exchange (ETDEWEB)

    Fiebach, J.B.; Jansen, O.; Heiland, S.; Sartor, K. [Department of Neuroradiology, University of Heidelberg (Germany); Schellinger, P.D.; Hacke, W. [Department of Neurology, University of Heidelberg (Germany)

    2002-04-01

    Acute cerebral ischemic injury can be rapidly detected on diffusion-weighted images. The apparent diffusion coefficient (ADC) depends on the stage of cytotoxic edema and water content in the infarcted parenchyma. The purpose of this study is to determine the time course of ADC during the first days of ischemic stroke. These data should make it possible to distinguish between multiple stroke and a single progressive infarction. Eight patients with clinically diagnosed acute cerebral ischemia were examined by diffusion-weighted MRI from 2 to 20 h after onset of symptoms. Daily control scans were performed for up to 10 days. ADC values were analyzed from 55 MRI studies. Furthermore, ADC was measured in the tissue which showed a hyperintense signal at the first examination and in the contralateral tissue. White and gray matter were analyzed separately. Data were expressed as the ratio ADC (rADC) of lesion to control region of interest. All patients showed a uniform reduction in rADC from the first hours of stroke and decreasing to the 3rd day. The rADC increased again from the 4th day up to the point of pseudo-normalization on day 9. The gray matter showed a slightly faster increase than the white matter. rADC shows significant changes in the first days after stroke, following a rather uniform time course. Together with T2-weighted MRI this makes it possible to differentiate between hyperacute, acute, and chronic stroke. Furthermore, the age of an ischemia can be determined and multiple strokes can be distinguished from a single progressive stroke. (orig.)

  5. Diagnostic value of apparent diffusion coefficients to differentiate benign from malignant vertebral bone marrow lesions

    Energy Technology Data Exchange (ETDEWEB)

    Balliu, E. [Department of Magnetic Resonance, IDI Girona, Hospital Universitari de Girona Dr Josep Trueta, Girona (Spain)], E-mail: eballiu@gmail.com; Vilanova, J.C. [Department of Magnetic Resonance, Clinica Girona, Girona (Spain)], E-mail: Kvilanova@comg.es; Pelaez, I. [Department of Magnetic Resonance, IDI Girona, Hospital Universitari de Girona Dr Josep Trueta, Girona (Spain)], E-mail: isapelaezrx@yahoo.es; Puig, J. [Department of Magnetic Resonance, IDI Girona, Hospital Universitari de Girona Dr Josep Trueta, Girona (Spain)], E-mail: jpuigalcantara@yahoo.es; Remollo, S. [Department of Magnetic Resonance, IDI Girona, Hospital Universitari de Girona Dr Josep Trueta, Girona (Spain)], E-mail: sremollo@gmail.com; Barcelo, C. [Department of Computer Science and Applied Mathematics, University of Girona (Spain)], E-mail: carles.barcelo@udg.es; Barcelo, J. [Department of Magnetic Resonance, Clinica Girona, Girona (Spain)], E-mail: rmgirona@comg.es; Pedraza, S. [Department of Magnetic Resonance, IDI Girona, Hospital Universitari de Girona Dr Josep Trueta, Girona (Spain)], E-mail: sapedraza@gmail.com

    2009-03-15

    Aim: The aim of this study is to evaluate the value of the apparent diffusion coefficient (ADC) obtained in diffusion-weighted (DW) MR sequences for the differentiation between malignant and benign bone marrow lesions. Method: Forty-five patients with altered signal intensity vertebral bodies on conventional MR sequences were included. The cause of altered signal intensity was benign osteoporotic collapse in 16, acute neoplastic infiltration in 15, and infectious processes in 14; based on plain-film, CT, bone scintigraphy, conventional MR studies, biopsy or follow-up. All patients underwent isotropic DW MR images (multi-shot EPI, b values of 0 and 500 s/mm{sup 2}). Signal intensity at DW MR images was evaluated and ADC values were calculated and compared between malignancy, benign edema and infectious spondylitis. Results: Acute malignant fractures were hyperintense compared to normal vertebral bodies on the diffusion-weighted sequence, except in one patient with sclerotic metastases. Mean ADC value from benign edema (1.9 {+-} 0.39 x 10{sup -3} mm{sup 2}/s) was significantly (p < 0.0001) higher than untreated metastasic lesions (0.9 {+-} 1.3 x 10{sup -3} mm{sup 2}/s). Mean ADC value of infectious spondilytis (0.96 {+-} 0.49 x 10{sup -3} mm{sup 2}/s) was not statistically (p > 0.05) different from untreated metastasic lesions. ADC value was low (0.75 x 10{sup -3} mm{sup 2}/s) in one case of subacute benign fracture. Conclusions: ADC values are a useful complementary tool to characterize bone marrow lesions, in order to distinguish acute benign fractures from malignant or infectious bone lesions. However, ADC values are not valuable in order to differentiate malignancy from infection.

  6. Measurement and modeling of osmotic coefficients of binary mixtures (alcohol + 1,3-dimethylpyridinium methylsulfate) at T = 323.15 K

    International Nuclear Information System (INIS)

    Gomez, Elena; Calvar, Noelia; Dominguez, Angeles; Macedo, Eugenia A.

    2011-01-01

    Research highlights: → The osmotic coefficients of binary mixtures (alcohol + ionic liquid) were determined. → The measurements were carried out with a vapor pressure osmometer at 323.15 K. → The Pitzer-Archer, and the MNRTL models were used to correlate the experimental data. → Mean molal activity coefficients and excess Gibbs free energies were calculated. - Abstract: Measurement of osmotic coefficients of binary mixtures containing several primary and secondary alcohols (1-propanol, 2-propanol, 1-butanol, 2-butanol, and 1-pentanol) and the pyridinium-based ionic liquid 1,3-dimethylpyridinium methylsulfate were performed at T = 323.15 K using the vapor pressure osmometry technique, and from experimental data, vapor pressure, and activity coefficients were determined. The extended Pitzer model modified by Archer, and the NRTL model modified by Jaretun and Aly (MNRTL) were used to correlate the experimental osmotic coefficients, obtaining standard deviations lower than 0.017 and 0.054, respectively. From the parameters obtained with the extended Pitzer model modified by Archer, the mean molal activity coefficients and the excess Gibbs free energy for the studied binary mixtures were calculated. The effect of the cation is studied comparing the experimental results with those obtained for the ionic liquid 1,3-dimethylimidazolium methylsulfate.

  7. Singular 1-soliton solution of the nonlinear variable-coefficient diffusion reaction and mKdV equations

    Science.gov (United States)

    Guner, Ozkan; Bekir, Ahmet; Unsal, Omer; Cevikel, Adem C.

    2017-01-01

    In this paper, we pay attention to the analytical method named, ansatz method for finding the exact solutions of the variable-coefficient modified KdV equation and variable coefficient diffusion-reaction equation. As a result the singular 1-soliton solution is obtained. These solutions are important for the explanation of some practical physical problems. The obtained results show that these methods provides a powerful mathematical tool for solving nonlinear equations with variable coefficients. This method can be extended to solve other variable coefficient nonlinear partial differential equations.

  8. Determination of uranium self-diffusion coefficients in the U O2 nuclear fuel by secondary ion mass spectrometry

    International Nuclear Information System (INIS)

    Ferraz, Wilmar Barbosa

    1998-01-01

    This study of uranium self-diffusion in UO 2 presents a great technological interest because its knowledge is necessary to interpret the mechanism of many important processes like, for example, sintering, creep, grain growth, in-reactor densification and others. The present work deals with new measurements of uranium diffusion in UO 2 single crystals and polycrystals through an original mythology based on the utilization of 235 U as tracer and depth profiling by secondary ions mass spectrometry (SIMS). The diffusion experiments were performed between 1498 and 1697 deg C, in H 2 atmosphere. In our experimental conditions, the uranium volume diffusion coefficients measured in UO 2 single crystals can be described by the following Arrhenius relation: D(cm 2 /s) = 8.54x10 -7 exp[-4.4(eV)/K T]. The uranium grain-boundary diffusion experiments performed in UO 2 polycrystals corresponded to the type-B diffusion. In this case, it was possible to determine the product D'δ, where D is the grain-boundary diffusion and is the width of the grain-boundary. In our experimental conditions, the product D'δ can be described by the following relation: D'δ (cm 3 /s) = 1.62x10 -5 exp[-5.6(eV)/K T]. These results that the uranium volume diffusion coefficients, measured in UO 2 single crystals, are 5 orders of magnitude lower than the uranium grain boundary diffusion coefficients measured in UO 2 polycrystalline pellets, in the same experimental conditions. This large difference between these two types of diffusivities indicates that the grain boundary is a preferential via for uranium diffusion in UO 2 polycrystalline pellet. (author)

  9. Improving malignancy prediction in breast lesions with the combination of apparent diffusion coefficient and dynamic contrast-enhanced kinetic descriptors

    International Nuclear Information System (INIS)

    Nogueira, Luisa; Brandão, Sofia; Matos, Eduarda; Gouveia Nunes, Rita; Ferreira, Hugo Alexandre; Loureiro, Joana; Ramos, Isabel

    2015-01-01

    Aim: To assess how the joint use of apparent diffusion coefficient (ADC) and kinetic parameters (uptake phase and delayed enhancement characteristics) from dynamic contrast-enhanced (DCE) can boost the ability to predict breast lesion malignancy. Materials and methods: Breast magnetic resonance examinations including DCE and diffusion-weighted imaging (DWI) were performed on 51 women. The association between kinetic parameters and ADC were evaluated and compared between lesion types. Models with binary outcome of malignancy were studied using generalized estimating equations (GEE), (GEE), and using kinetic parameters and ADC values as malignancy predictors. Model accuracy was assessed using the corrected maximum quasi-likelihood under the independence confidence criterion (QICC). Predicted probability of malignancy was estimated for the best model. Results: ADC values were significantly associated with kinetic parameters: medium and rapid uptake phase (p<0.001) and plateau and washout curve types (p=0.004). Comparison between lesion type showed significant differences for ADC (p=0.001), early phase (p<0.001), and curve type (p<0.001). The predicted probabilities of malignancy for the first ADC quartile (≤1.17×10 −3  mm 2 /s) and persistent, plateau and washout curves, were 54.6%, 86.9%, and 97.8%, respectively, and for the third ADC quartile (≥1.51×10 −3  mm 2 /s) were 3.2%, 15.5%, and 54.8%, respectively. The predicted probability of malignancy was less than 5% for 18.8% of the lesions and greater than 33% for 50.7% of the lesions (24/35 lesions, corresponding to a malignancy rate of 68.6%). Conclusion: The best malignancy predictors were low ADCs and washout curves. ADC and kinetic parameters provide differentiated information on the microenvironment of the lesion, with joint models displaying improved predictive performance. -- Highlights: •ADC and kinetic parameters provide diverse information regarding lesion environment. •The best predictors

  10. Diffusion-weighted magnetic resonance imaging of the normal endometrium: temporal and spatial variations of the apparent diffusion coefficient

    Energy Technology Data Exchange (ETDEWEB)

    Fornasa, Francesca; Montemezzi, Stefania [Dept. of Radiology, San Bonifacio Hospital, Verona (Italy)], e-mail: francescafornasa@libero.it

    2012-06-15

    Background: Diffusion-weighted magnetic resonance imaging (DWI) is increasingly used in the diagnosis of endometrial disease. No complete knowledge, however, exists yet of the influence of physiology on the endometrial apparent diffusion coefficient (ADC) values on which DWI is based. Purpose: To establish whether the ADC values measured with DWI in the endometrium of healthy reproductive-aged women significantly vary from the early proliferative to the periovulatory phase of the menstrual cycle and between the fundus and the isthmus of the uterus. Material and Methods: In 17 women the endometrial ADC values measured on the fifth menstrual day, both at the fundus and at the isthmus of the uterus, were compared to the values obtained on the 14th day before the subsequent cycle. In 81 women (menstrual day: fifth through 21st) the endometrial ADC values measured at the fundus were compared to the values obtained at the isthmus of the uterus. All examinations were performed with a 1.5 T magnet (b values: 0 and 800 mm/s{sup 2}). The results were analyzed by means of Student's t-test per paired data. Results: The endometrial ADC values measured on the fifth day of the menstrual cycle were lower than those obtained in the periovulatory phase both at the fundus (mean 0.923 vs. 1.256 x 10{sup -}3 mm{sup 2}/s) and at the isthmus (mean 1.297 vs. 1.529 x 10{sup -}3 mm{sup 2}/s) of the uterus. The endometrial ADC values measured at the fundus of the uterus were lower than those obtained at the isthmus (mean 1.132 vs. 1.420 x 10{sup -}3 mm{sup 2}/s) through the menstrual cycle. All these differences were highly significant (P < 0.001) at statistical analysis. Conclusion: Physiological variations occurring in endometrial ADC values of healthy women should be considered by the radiologists when interpreting DWI examinations in patients with endometrial disease.

  11. Role of PROPELLER diffusion-weighted imaging and apparent diffusion coefficient in the evaluation of pituitary adenomas

    International Nuclear Information System (INIS)

    Mahmoud, Omar M.; Tominaga, Atsushi; Amatya, Vishwa Jeet; Ohtaki, Megu; Sugiyama, Kazuhiko; Sakoguchi, Tetsuhiko; Kinoshita, Yasuyuki; Takeshima, Yukio; Abe, Nobukazu; Akiyama, Yuji; El-Ghoriany, Ahmad I.; Alla, Abdel Karim H. Abd; El-Sharkawy, Mostafa A.M.; Arita, Kazunori; Kurisu, Kaoru; Yamasaki, Fumiyuki

    2011-01-01

    Objective: The relationship between tumor consistency and apparent diffusion coefficient (ADC) values is controversial. We evaluated the role of the ADC using an advanced diffusion-weighted imaging (DWI) technique. We employed periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) DWI acquired on a 3-T magnetic resonance imaging (MRI) scanner to assess the consistency of pituitary adenomas and examined the relationship between the ADC and the hormone secretion status of the tumors and their MIB-1 labeling index (MIB-1 LI). Materials and methods: The study protocol was approved by our institutional review board. We retrospectively studied 24 operated patients with pituitary adenomas who had undergone PROPELLER DWI on a 3-T MRI scanner. Conventional MRI findings were expressed as the ratio of the signal intensity (SI) in the lesions to the SI of the normal white matter and the degree of contrast enhancement. Minimum-, mean-, and maximum ADC (ADC min , ADC mean , ADC max ) values were calculated. The consistency of the tumors was determined by neurosurgeons. All surgical specimens were submitted for histological study to calculate the MIB-1 LI and the percent collagen content. Preoperative MRI-, intraoperative-, and histological findings were analyzed by a statistician. Results: Our study included 15 soft-, 5 fibrous-, and 4 hard tumors. Tumor consistency was strongly associated with the percent collagen content. However, neither the tumor consistency nor the percent collagen content was correlated with MRI findings or ADC values. The SI of growth hormone-producing adenomas on T2-WI was lower than of the other pituitary adenomas studied (p < 0.01); no other significant difference was found in the ADC or on conventional MRI between pituitary adenomas with different secretory functions. The MIB-1 LI of pituitary adenomas was not correlated with their appearance on conventional MRI or their ADC values. Conclusion: Using the PROPELLER DWI

  12. Diffusion-weighted MRI of epithelial ovarian cancers: Correlation of apparent diffusion coefficient values with histologic grade and surgical stage

    International Nuclear Information System (INIS)

    Oh, Ji-Won; Rha, Sung Eun; Oh, Soon Nam; Park, Michael Yong; Byun, Jae Young; Lee, Ahwon

    2015-01-01

    Highlights: •The solid component of all invasive epithelial cancers showed high b 1000 signal intensity. •ADCs can predict the histologic grade of epithelial ovarian cancer. •ADCs correlate negatively to the surgical stage of epithelial ovarian cancer. •ADCs may be useful imaging biomarkers to assess epithelial ovarian cancer. -- Abstract: Objective: The purpose of this article is to correlate the apparent diffusion coefficient (ADC) values of epithelial ovarian cancers with histologic grade and surgical stage. Materials and methods: We enrolled 43 patients with pathologically proven epithelial ovarian cancers for this retrospective study. All patients underwent preoperative pelvic magnetic resonance imaging (MRI) including diffusion-weighted images with b value of 0 and 1000 s/mm 2 at 3.0-T unit. The mean ADC values of the solid portion of the tumor were measured and compared among different histologic grades and surgical stages. Results: The mean ADC values of epithelial ovarian cancers differed significantly between grade 1 (well-differentiated) and grade 2 (moderately-differentiated) (P = 0.013) as well as between grade 1 and grade 3 (poorly-differentiated) (P = 0.01); however, no statistically significant difference existed between grade 2 and grade 3 (P = 0.737). The receiver-operating characteristic analysis indicated that a cutoff ADC value of less than or equal to 1.09 × 10 −3 mm 2 /s was associated with 94.4% sensitivity and 85.7% specificity in distinguishing grade 1 and grade 2/3 cancer. The difference in mean ADC values was statistically significant for early stage (FIGO stage I) and advanced stage (FIGO stage II-IV) cancer (P = 0.011). The interobserver agreement for the mean ADC values of epithelial ovarian cancers was excellent. Conclusion: The mean ADC values of the solid portion of epithelial ovarian cancers negatively correlated to histologic grade and surgical stage. The mean ADC values may be useful imaging biomarkers for assessment

  13. Comparison of methods for estimating the intraclass correlation coefficient for binary responses in cancer prevention cluster randomized trials.

    Science.gov (United States)

    Wu, Sheng; Crespi, Catherine M; Wong, Weng Kee

    2012-09-01

    The intraclass correlation coefficient (ICC) is a fundamental parameter of interest in cluster randomized trials as it can greatly affect statistical power. We compare common methods of estimating the ICC in cluster randomized trials with binary outcomes, with a specific focus on their application to community-based cancer prevention trials with primary outcome of self-reported cancer screening. Using three real data sets from cancer screening intervention trials with different numbers and types of clusters and cluster sizes, we obtained point estimates and 95% confidence intervals for the ICC using five methods: the analysis of variance estimator, the Fleiss-Cuzick estimator, the Pearson estimator, an estimator based on generalized estimating equations and an estimator from a random intercept logistic regression model. We compared estimates of the ICC for the overall sample and by study condition. Our results show that ICC estimates from different methods can be quite different, although confidence intervals generally overlap. The ICC varied substantially by study condition in two studies, suggesting that the common practice of assuming a common ICC across all clusters in the trial is questionable. A simulation study confirmed pitfalls of erroneously assuming a common ICC. Investigators should consider using sample size and analysis methods that allow the ICC to vary by study condition. Copyright © 2012. Published by Elsevier Inc.

  14. On the Influence of the Extrinsic Information Scaling Coefficient on the Performance of Single and Double Binary Turbo Codes

    Directory of Open Access Journals (Sweden)

    BALTA, H.

    2013-05-01

    Full Text Available This paper presents a study on the influence of the extrinsic information scaling coefficient value (eic on the bit and frame error rate (BER/FER, for single and double binary turbo codes (S/DBTC decoded with maximum a posteriori (MAP and maximum logarithmic MAP (MaxLogMAP component algorithms. Firstly, we estimate the distance spectrum of the code with the so-called error impulse method (EIM, and we analyze its dependence as well as the dependence of the asymptotic FER on eic. Secondly, we estimate the actual FER using Monte Carlo simulations with eic as a parameter. The comparison of the FER(eic curves obtained by the two methods allows us, on the one hand, to assess the quality of the decoding algorithms, and on the other hand, to estimate the very low BER/FER performance of TCs, where the Monte Carlo method is practically unusable. The results presented also provide a practical guide for the appreciation of the optimal value of the scaling factor, eic. We may notice that also the MAP algorithm performance could be improved using eic<1.

  15. Assessment of odor activity value coefficient and odor contribution based on binary interaction effects in waste disposal plant

    Science.gov (United States)

    Wu, Chuandong; Liu, Jiemin; Yan, Luchun; Chen, Haiying; Shao, Huiqi; Meng, Tian

    2015-02-01

    Odor activity value (OAV) has been widely used for the assessment of odor pollution from various sources. However, little attention has been paid to the extreme OAV variation and potential inaccuracies of odor contribution assessment caused by odor interaction effects. The objective of this study is to assess the odor interaction effect for precise assessment of odor contribution. In this paper, samples were collected from a food waste disposal plant, and analyzed by instrumental and olfactory method to conclude odorants' occurrence and OAV. Then odor activity value coefficient (γ) was first proposed to evaluate the type and the level of binary interaction effects based on determination of OAV variation. By multiplying OAV and γ, odor activity factor (OAF) was used to reflect the real OAV. Correlation between the sum of OAF and odor concentration reached 80.0 ± 5.7%, which was 10 times higher than the sum of OAV used before. Results showed that hydrogen sulfide contributed most (annual average 66.4 ± 15.8%) to odor pollution in the waste disposal plant. However, as odor intensity of samples in summer rising, odor contribution of trimethylamine increased to 48.3 ± 3.7% by the strong synergistic interaction effect, while odor contribution of phenol decreased to 0.1 ± 0.02% for the increasing antagonistic interaction effect.

  16. Assessment and quantification of sources of variability in breast apparent diffusion coefficient (ADC) measurements at diffusion weighted imaging

    International Nuclear Information System (INIS)

    Giannotti, E.; Waugh, S.; Priba, L.; Davis, Z.; Crowe, E.; Vinnicombe, S.

    2015-01-01

    Highlights: • Inter-scan errors have minimal contribution to ADC measurement variability. • Intra-observer measures of ADC values in breast cancer are excellent. • ADC measures in whole tumour are more reproducible than minimum ADC measures. • ADC measurement error is most influenced by multiple readers. - Abstract: Purpose: Apparent Diffusion Coefficient (ADC) measurements are increasingly used for assessing breast cancer response to neoadjuvant chemotherapy although little data exists on ADC measurement reproducibility. The purpose of this work was to investigate and characterise the magnitude of errors in ADC measures that may be encountered in such follow-up studies- namely scanner stability, scan–scan reproducibility, inter- and intra- observer measures and the most reproducible measurement of ADC. Methods: Institutional Review Board approval was obtained for the prospective study of healthy volunteers and written consent acquired for the retrospective study of patient images. All scanning was performed on a 3.0-T MRI scanner. Scanner stability was assessed using an ice-water phantom weekly for 12 weeks. Inter-scan repeatability was assessed across two scans of 10 healthy volunteers (26–61 years; mean: 44.7 years). Inter- and intra-reader analysis repeatability was measured in 52 carcinomas from clinical patients (29–70 years; mean: 50.0 years) by measuring the whole tumor ADC value on a single slice with maximum tumor diameter (ADC S ) and the ADC value of a small region of interest (ROI) on the same slice (ADC min ). Repeatability was assessed using intraclass correlation coefficients (ICC) and coefficients of repeatability (CoR). Results: Scanner stability contributed 6% error to phantom ADC measurements (0.071 × 10 −3 mm 2 /s; mean ADC = 1.089 × 10 −3 mm 2 /s). The measured scan-scan CoR in the volunteers was 0.122 × 10 −3 mm 2 /s, contributing an error of 8% to the mean measured values (ADC scan1 = 1.529 × 10 −3 mm 2 /s; ADC scan

  17. Comparison of apparent diffusion coefficient in spondylarthritis axial active inflammatory lesions and type 1 modic changes

    Energy Technology Data Exchange (ETDEWEB)

    Dallaudière, Benjamin, E-mail: benjamin.dallaudiere@gmail.com [Hôpital Bichat – Claude Bernard, Service de Radiologie, 46, rue Henri Huchard, Paris 75018 (France); Hôpital Bichat – Claude Bernard, Inserm U698, 46, rue Henri Huchard, Paris 75018 (France); Université Paris Diderot, Paris (France); Dautry, Raphaël, E-mail: raphael_dautry@yahoo.fr [Hôpital Bichat – Claude Bernard, Service de Radiologie, 46, rue Henri Huchard, Paris 75018 (France); Université Paris Diderot, Paris (France); Preux, Pierre-Marie, E-mail: pierre-marie.preux@unilim.fr [Faculté de Médecine de Limoges, Unité fonctionelle de recherche clinique et de biostatistique, hôpital Le Cluzeau, 23, avenue Dominique Larrey, 87042 Limges Cedex (France); Perozziello, Anne, E-mail: aperozziello@gmail.com [Université Paris Diderot, Paris (France); Hôpital Bichat – Claude Bernard, Unité de recherche clinique, 46, rue Henri Huchard, Paris 75018 (France); Lincot, Julien, E-mail: julienlincot@gmail.com [Hôpital Bichat – Claude Bernard, Service de Radiologie, 46, rue Henri Huchard, Paris 75018 (France); Schouman-Claeys, Elisabeth, E-mail: elisabeth.schouman-claeys@bch.aphp.fr [Hôpital Bichat – Claude Bernard, Service de Radiologie, 46, rue Henri Huchard, Paris 75018 (France); Université Paris Diderot, Paris (France); and others

    2014-02-15

    Objective: The goal of this study was to evaluate whether the values of ADC in spondylarthritis axial active inflammatory lesions are different from ADC values in type 1 Modic changes. Subjects and methods: 95 patients with recent lumbar pain, including 46 patients with diagnosed or suspected spondylarthritis and 49 patients with purely degenerative history, underwent spine MRI. T1w, STIR, and diffusion-weighted images (DWI) were obtained. Two musculoskeletal radiologists interpreted the images. Axial active inflammatory lesions from the SpA group and type 1 Modic changes from the degenerative group were identified on T1w and STIR sequences. ADC values from these lesions and from healthy subchondral bone were compared. Results: All axial active inflammatory lesions (n = 27) and type 1 Modic changes (n = 22) identified in T1w and STIR images were visible on DWI. ADC values were significantly higher (p < 0.05) for axial active inflammatory lesions (median = 0.788 × 10{sup −3} mm{sup 2}/s, IQR 25–75 [0.7 × 10{sup −3} mm{sup 2}/s; 0.9 × 10{sup −3} mm{sup 2}/s]) than for type 1 Modic changes (median = 0.585 × 10{sup −3} mm{sup 2}/s, IQR 25–75 [0.55 × 10{sup −3} mm{sup 2}/s; 0.60 × 10{sup −3} mm{sup 2}/s]) and normal subchondral bone (median = 0.443 × 10{sup −3} mm{sup 2}/s, IQR 25–75 [0.40 × 10{sup −3} mm{sup 2}/s; 0.50 × 10{sup −3} mm{sup 2}/s]). Intra-class correlation coefficients for intra- and inter-reader ADC values comparison were excellent (0.89 and 0.98 respectively). Conclusion: DWI is a sensitive and fast sequence that offer the possibility of quantifying diffusion coefficients of the lesions, which could help to discriminate between spondylarthritis axial active inflammatory and type 1 Modic changes.

  18. Behavior of specific heat and self diffusion coefficient of sodium near transition temperature: a molecular dynamics study

    International Nuclear Information System (INIS)

    Ahmed, N.; Khan, G.

    1990-09-01

    In this report the author used of a very useful technique of simulation and applied it to successfully for determining the various properties of sodium, both in liquid and solid phase near transition point. As a first step the determination of specific heat and diffusion coefficient have been carried out. In liquid state the molecular dynamics (MD) values calculated matched the experimental data. But in solid state the diffusion coefficient obtained were not consistent with the one expected for a solid, rather the values obtained suggested that sodium remained in liquid state even below the melting point. (A.B.)

  19. Apparent diffusion coefficient values and dynamic contrast enhancement patterns in differentiating seminomas from nonseminomatous testicular neoplasms

    International Nuclear Information System (INIS)

    Tsili, Athina C.; Sylakos, Anastasios; Ntorkou, Alexandra; Stavrou, Sotirios; Astrakas, Loukas G.; Sofikitis, Nikolaos; Argyropoulou, Maria I.

    2015-01-01

    Highlights: • Functional MRI in the characterization of testicular germ cell tumors was assessed. • ADC values proved useful in the characterization of testicular germ cell tumors. • Testicular germ cell tumors had similar enhancement patterns of dynamic MRI. - Abstract: Introduction: The aim of this study is to investigate the role of apparent diffusion coefficient (ADC) values and dynamic contrast enhancement (DCE) patterns in differentiating seminomas from nonseminomatous germ cell tumors (NSGCTs). Materials and methods: The MRI examinations of the scrotum of 26 men with histologically proven testicular GCTs were reviewed. DWI was performed in all patients, using a single shot, multi-slice spin-echo planar diffusion pulse sequence and b-values of 0 and 900 s/mm 2 . Subtraction DCE-MRI was performed in 20 cases using a 3D fast-field echo sequence after gadolinium administration. Time-signal intensity curves were created and semi-quantitative parameters (peak enhancement, time to peak, wash-in and wash-out rate) were calculated. The Student's t-test was used to compare the mean values of ADC, peak enhancement, time to peak, wash-in and wash-out rate between seminomas and NSGCTs. ROC analysis was also performed. Results: Histopathology disclosed the presence of 15 seminomas and 11 NSGCTs. The mean ± s.d. of ADC values (× 10 −3 mm 2 /s) of seminomas (0.59 ± 0.009) were significantly lower than those of NSGCTs (0.90 ± 0.33) (P = 0.01). The optimal ADC cut-off value was 0.68 × 10 −3 mm 2 /s. No differences between the two groups were observed for peak enhancement (P = 0.18), time to peak (P = 0.63) wash-in rate (P = 0.32) and wash-out rate (P = 0.18). Conclusions: ADC values may be used to preoperatively differentiate seminomas from NSGCTs

  20. The use of MRI apparent diffusion coefficient (ADC) in monitoring the development of brain infarction

    International Nuclear Information System (INIS)

    Shen, Jian-Min; Xia, Xian-Wu; Kang, Wu-Gen; Yuan, Jian-Jun; Sheng, Liang

    2011-01-01

    To study the rules that apparent diffusion coefficient (ADC) changes with time and space in cerebral infarction, and to provide the evidence in defining the infarction stages. 117 work-ups in 98 patients with cerebral infarction (12 hyperacute, 43 acute, 29 subacute, 10 steady, and 23 chronic infarctions) were imaged with both conventional MRI and diffusion weighted imaging. The average ADC values, the relative ADC (rADC) values, and the ADC values or rADC values from the center to the periphery of the lesion were calculated. The average ADC values and the rADC values of hyperacute and acute infarction lesion depressed obviously. rADC values in hyperacute and acute stage was minimized, and increased progressively as time passed and appeared as 'pseudonormal' values in approximately 8 to 14 days. Thereafter, rADC values became greater than normal in chronic stage. There was positive correlation between rADC values and time (P < 0.01). The ADC values and the rADC values in hyperacute and acute lesions had gradient signs that these lesions increased from the center to the periphery. The ADC values and the rADC values in subacute lesions had adverse gradient signs that these lesions decreased from the center to the periphery. The ADC values of infarction lesions have evolution rules with time and space. The evolution rules with time and those in space can be helpful to decide the clinical stage, and to provide the evidence in guiding the treatment or judging the prognosis in infarction

  1. Correlation of MRI apparent diffusion coefficient of invasive breast cancer with tumor tissue growth and angiogenesis

    Directory of Open Access Journals (Sweden)

    Ze-Hong Fu

    2017-08-01

    Full Text Available Objective: To study the correlation of MRI apparent diffusion coefficient (ADC value of invasive breast cancer with tumor tissue growth and angiogenesis. Methods: Patients with breast mass who were treated in Wuhan No. 6 Hospital between March 2014 and May 2017 were selected as the research subjects and divided into group A with invasive ductal carcinoma, group B with intraductal carcinoma and group C with benign lesion according to the biopsy results, magnetic resonance diffusion-weighted imaging was conducted to determine ADC values, and biopsy tissue was taken to determine the expression of proliferation genes and angiogenesis genes. Results: USP39, CyclinD1, VEGF, bFGF, Angplt-2, Angplt-3 and Angplt-4 protein expression levels in lesions of group A and group B were significantly higher than those of group C while ADC value as well as ALEX1 and Bax protein expression levels were significantly lower than those of group C; USP39, CyclinD1, VEGF, bFGF, Angplt-2, Angplt-3 and Angplt-4 protein expression levels in lesions of group A were significantly higher than those of group B while ADC value as well as ALEX1 and Bax protein expression levels was significantly lower than those of group B; USP39, CyclinD1, VEGF, bFGF, Angplt-2, Angplt-3 and Angplt-4 protein expression levels in invasive breast cancer tissue with high ADC value were significantly lower than those in invasive breast cancer tissue with low ADC value while ALEX1 and Bax protein expression levels were significantly higher than those in invasive breast cancer tissue with low ADC value. Conclusion: The decrease of ADC value of invasive breast cancer is closely related to cancer cell proliferation and angiogenesis.

  2. Diagnostic performance of apparent diffusion coefficient for predicting histological grade of hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Nishie, Akihiro; Tajima, Tsuyoshi; Asayama, Yoshiki; Ishigami, Kousei; Kakihara, Daisuke; Nakayama, Tomohiro; Takayama, Yukihisa; Okamoto, Daisuke; Fujita, Nobuhiro

    2011-01-01

    Objective: To investigate whether the histological grade of hepatocellular carcinoma (HCC) can be predicted using the apparent diffusion coefficient (ADC). Materials and Methods: This retrospective study group consisted of 80 patients with 85 surgically resected HCCs who underwent preoperative MRI exams including diffusion-weighted imaging. The tumors were histologically classified into five groups as follows: five well (w-), 17 well to moderately (wm-), 37 moderately (m-), 16 moderately to poorly (mp-), and 10 poorly (p-) differentiated HCCs. For ADC measurement of each HCC, the largest possible region of interest was placed on the solid region on the ADC map where ADC was considered to be the lowest. The average ADCs of the five histological grades were compared using Spearman's rank correlation test and Student's t-test, and the diagnostic performance of ADC for mp- and p-HCCs was also evaluated using a receiver operating characteristic-based positive test. Results: The average ADC of p-HCC (0.76 ± 0.10 x 10 -3 mm 2 /s) was significantly lower than those of the other four histological grades. The average ADC of mp-HCCs (0.99 ± 0.20 x 10 -3 mm 2 /s) was significantly lower than those of w-, wm- and m-HCCs. The sensitivity, specificity, PPV, NPV, and accuracy, when an ADC of 0.972 or lower was considered an indicator of mp- and p-HCCs, were 73.1%, 72.9%, 54.3%, 86.0% and 72.9%, respectively. Conclusion: ADCs of mp- and p-HCCs were lower than those of w-, wm- and m-HCCs. ADC can contribute to radiological diagnosis of poorly differentiated components in HCCs.

  3. Determination of the cationic self-diffusion coefficient in ThO2-5%UO2 nuclear fuel

    International Nuclear Information System (INIS)

    Sabioni, A.C.S.

    1984-01-01

    The cation self-diffusion coefficient for the ThO 2 -5%UO 2 by means of the densification model developed by Assmann and Stehle was determined. The experimental data of the fuel densification, used in the calculations, were obtained from thermal resinter tests. Our result is comparable to previously published values for U and Th diffusion in polycrystalline ThO 2 and (Th, U)O 2 . (Author) [pt

  4. Determination of the effective diffusion coefficient of water through cement-based materials when applying an electrical field

    International Nuclear Information System (INIS)

    Wattez, T.

    2013-01-01

    The safety and the reliability of a radioactive waste repository rely essentially on the confinement ability of the waste package and the storing structure. In the case of the low-level and intermediate level short-lived radioactive waste, the confinement property, relying on solid matrices made of cement-based materials, is assessed through a natural diffusion test, using a radioactive tracer, from which an effective diffusion coefficient is deduced. The evolution of the materials and more particularly the enhancement of the confinement properties of cement-based materials lead to test duration from a couple of months to a couple of years. The main objective of the present work involves the determination of the effective diffusion coefficient of reference chemical species, in our case the tritiated water, within a shorter time. The theoretical foundation is based on the description of ionic species mass transfer under the effects of an electrical field. With the definitions of a precise experimental protocol and of a formation factor, considered as an intrinsic topological feature of the porous network, it is possible to determine the effective diffusion coefficient of tritiated water for various types of concretes and mortars, and this within a few hours only. The comparison between the developed accelerated test, based on the application of a constant electrical field, and the normed natural diffusion test, using tritiated water, underlined two critical issues. First, omitting the impact of the radioactive decay of tritium during a natural diffusion test, leads to a non-negligible underestimation of the effective diffusion coefficient. Second, maintaining samples in high relative humidity conditions after casting is essential in order to avoid contrasted and unrelated results when performing the electrokinetic tests. Eventually, the validation of the electrokinetics technique, main objective of this work, rests on the assessment of the theoretical hypothesis

  5. Simulation study on the measurements of diffusion coefficients in solid materials by short-lived radiotracer beams

    CERN Document Server

    Jeong, S C; Kawakami, H

    2003-01-01

    We have examined, by a computer simulation, an on-line measurement of diffusion coefficients by using a short-lived alpha particle emitter, sup 8 Li (half life of 0.84s), as a radiotracer. The energy spectra of alpha particles emitted from diffusing sup 8 Li primarily implanted in the sample of LiAl ar simulated as a measure of the diffusion of sup 8 Li in the sample. As a possible time sequence for the measurement, a time cycle of 6s, i.e. the implantation of sup 8 Li for 1.5s and subsequent diffusion for 4.5s, is supposed. The sample is primarily set on a given temperature for the measurement. The time-dependent yields of alpha particles during the time cycle reveal the possibility to measure the diffusion coefficient with an accuracy of 10% if larger than 1 x 10 sup - sup 9 cm sup 2 /s, by the comparison with the experimental spectra measured at the temperature, i.e. at a certain diffusion coefficient. (author)

  6. A new phantom using polyethylene glycol as an apparent diffusion coefficient standard for MR imaging.

    Science.gov (United States)

    Matsuya, Ryohei; Kuroda, Masahiro; Matsumoto, Yoshitsugu; Kato, Hirokazu; Matsuzaki, Hidenobu; Asaumi, Junichi; Murakami, Jun; Katashima, Kazunori; Ashida, Masakazu; Sasaki, Takanori; Sei, Tetsuro; Himei, Kengo; Katsui, Kuniaki; Katayama, Norihisa; Takemoto, Mitsuhiro; Kanazawa, Susumu; Mimura, Seiichi; Oono, Seiichiro; Kitayama, Takuichi; Tahara, Seiji; Inamura, Keiji

    2009-10-01

    In recent years, magnetic resonance imaging (MRI) with diffusion-weighted imaging (DWI) has seen wide clinical use, such as for early detection of cerebrovascular diseases and whole body screening for tumors. The apparent diffusion coefficient (ADC) standard phantom, which mimics the ADC values of several lesions in the body, is indispensable for the development of new pulse sequences for DWI, such as diffusion-weighted whole-body imaging with background body-signal suppression (DWIBS). However, information on the ADC values of the previously reported ADC standard phantoms is limited, because these phantoms were made using only a few different materials at a limited range of concentrations, and the ADC values were measured only at certain temperatures. It has been considered difficult, if not impossible, to create a phantom that provides arbitrary ADC values, because it is difficult to calculate the concentrations of the materials and the temperature at ADC measurement. In this study, we used polyethylene glycol (PEG) as a phantom material, and developed an empirical formula to calculate the PEG concentration at any measurement temperature to obtain arbitrary ADC values of the phantom. DWI images of phantoms made using seven different PEG concentrations were taken under heating from 17 to 46 degrees C at 1 degrees C intervals. Using ADC values calculated from these DWI images, we developed two empirical formulas: i) an empirical formula to calculate the ADC values of phantoms made using any PEG concentration at any measurement temperature; and ii) an empirical formula to calculate PEG concentrations to obtain arbitrary ADC values at any measurement temperature. We inspected the accuracy of these empirical formulas by newly made PEG phantoms. A comparison between the ADC values calculated with the empirical formulas and the measured ADC values confirmed the high accuracy of these formulas. PEG phantoms are safe, inexpensive and easy to make, compared with the

  7. Thermal, Mutual and Self-Diffusivities in Binary Liquid Mixtures Consisting of n-Alkanes with Dissolved Gases at Infinite Dilution.

    Science.gov (United States)

    Giraudet, Cédric; Klein, Tobias; Zhao, Guanjia; Rausch, Michael Heinrich; Koller, Thomas M; Fröba, Andreas Paul

    2018-02-27

    In the present study, dynamic light scattering (DLS) experiments and molecular dynamics (MD) simulations were used for the investigation of the molecular diffusion in binary mixtures of liquids with dissolved gases at macroscopic thermodynamic equilibrium. Model systems based on the n-alkanes n-hexane or n-decane with dissolved hydrogen, helium, nitrogen, or carbon monoxide were studied at temperatures between 303 and 423 K and at gas mole fractions below 0.06. With DLS, the relaxation behavior of microscopic equilibrium fluctuations in concentration and temperature is analyzed to determine simultaneously mutual and thermal diffusivity in an absolute way. The present measurements document that even for mole gas fractions of 0.007 and Lewis numbers close to 1, reliable mutual diffusivities with an average expanded uncertainty (k = 2) of 13% can be obtained. Using suitable molecular models for the mixture components, the self-diffusion coefficient of the gases was determined by MD simulations with an averaged expanded uncertainty (k = 2) of 7%. The DLS experiments showed that the thermal diffusivity of the studied systems is not affected by the dissolved gas and agrees with the reference data for the pure n-alkanes. In agreement with theory, mutual diffusivities and self-diffusivities were found to be equal mostly within combined uncertainties at conditions approaching infinite dilution of the gas. Our DLS and MD results, representing the first available data for the present systems, reveal distinctly larger mass diffusivities for mixtures containing hydrogen or helium compared to mixtures containing nitrogen or carbon monoxide. Based on the broad range of mass diffusivities of the studied gas-liquid systems covering about two orders of magnitude from about 10 -9 to 10 -7 m 2 ·s -1 , effects of the solvent and solute properties on the temperature-dependent mass diffusivities are discussed. This contributed to the development of a simple semi-empirical correlation

  8. Prediction of the therapeutic effect of dienogest in ovarian endometrial cysts using the apparent diffusion coefficient.

    Science.gov (United States)

    Matsuura, Motoki; Tamate, Masato; Tabuchi, Yuta; Takada, Sakura; Tanaka, Ryoichi; Iwasaki, Masahiro; Saito, Tsuyoshi

    2014-08-01

    The purpose of this study was to investigate whether apparent diffusion coefficient (ADC) mean values can be used for predicting the treatment response in ovarian endometrial cyst patients with dienogest (DNG) administration. Eighteen patients received DNG (2 mg/day, orally) for 60 days, among whom 26 ovarian endometrial cysts were retrospectively identified. Mean ADC values of individual ovarian endometrial cysts were obtained by ADC maps inside the tumor. There was a significant correlation between ADC values and reduction ratio. When calculating the mean ADC values for three groups; more than 50%, 50-25% and less than 25%, ADC values significantly increased with increasing reduction ratio; 2.05 × 10(-3)mm(2)/s, 1.28 × 10(-3)mm(2)/s and 0.94 × 10(-3)mm(2)/s, respectively (p = 0.0180). Multiple regression analysis by reduction ratio (%), ADC mean values (× 10(-3)mm(2)/s), tumor longest diameter (cm) and CA125 (U/ml) revealed that tumor reduction ratio by DNG administration could be predicted by the following equation; R = 19.3 + 24.0x - 0.4y + 0.1z (R: Reduction ratio, x: ADC mean, y: Longest diameter, z: CA125). In conclusion, the ADC mean value is useful for the prediction of the treatment response in ovarian endometrial cyst patients with DNG administration.

  9. SPME-Based Ca-History Method for Measuring SVOC Diffusion Coefficients in Clothing Material.

    Science.gov (United States)

    Cao, Jianping; Liu, Ningrui; Zhang, Yinping

    2017-08-15

    Clothes play an important role in dermal exposure to indoor semivolatile organic compounds (SVOCs). The diffusion coefficient of SVOCs in clothing material (D m ) is essential for estimating SVOC sorption by clothing material and subsequent dermal exposure to SVOCs. However, few studies have reported the measured D m for clothing materials. In this paper, we present the solid-phase microextraction (SPME) based C a -history method. To the best of our knowledge, this is the first try to measure D m with known relative standard deviation (RSD). A thin sealed chamber is formed by a circular ring and two pieces of flat SVOC source materials that are tightly covered by the targeted clothing materials. D m is obtained by applying an SVOC mass transfer model in the chamber to the history of gas-phase SVOC concentrations (C a ) in the chamber measured by SPME. D m 's of three SVOCs, di-iso-butyl phthalate (DiBP), di-n-butyl phthalate (DnBP), and tris(1-chloro-2-propyl) phosphate (TCPP), in a cotton T-shirt can be obtained within 16 days, with RSD less than 3%. This study should prove useful for measuring SVOC D m in various sink materials. Further studies are expected to facilitate application of this method and investigate the effects of temperature, relative humidity, and clothing material on D m .

  10. Parameterization of the Age-Dependent Whole Brain Apparent Diffusion Coefficient Histogram

    Directory of Open Access Journals (Sweden)

    Uwe Klose

    2015-01-01

    Full Text Available Purpose. The distribution of apparent diffusion coefficient (ADC values in the brain can be used to characterize age effects and pathological changes of the brain tissue. The aim of this study was the parameterization of the whole brain ADC histogram by an advanced model with influence of age considered. Methods. Whole brain ADC histograms were calculated for all data and for seven age groups between 10 and 80 years. Modeling of the histograms was performed for two parts of the histogram separately: the brain tissue part was modeled by two Gaussian curves, while the remaining part was fitted by the sum of a Gaussian curve, a biexponential decay, and a straight line. Results. A consistent fitting of the histograms of all age groups was possible with the proposed model. Conclusions. This study confirms the strong dependence of the whole brain ADC histograms on the age of the examined subjects. The proposed model can be used to characterize changes of the whole brain ADC histogram in certain diseases under consideration of age effects.

  11. On conductivity, permittivity, apparent diffusion coefficient, and their usefulness as cancer markers at MRI frequencies.

    Science.gov (United States)

    Hancu, Ileana; Roberts, Jeannette Christine; Bulumulla, Selaka; Lee, Seung-Kyun

    2015-05-01

    To investigate the permittivity and conductivity of cancerous and normal tissues, their correlation to the apparent diffusion coefficient (ADC), and the specificity that they could add to cancer detection. Breast and prostate carcinomas were induced in rats. Conductivity and permittivity measurements were performed in the anesthetized animals using a dielectric probe and an impedance analyzer between 50 and 270 MHz. The correlations between ADCs (measured at 128 MHz) and conductivity values were investigated. Frequency-dependent discriminant functions were computed to assess the value that each parameter adds to cancer detection. Tumors exhibited higher permittivity than muscle tissue by 27%/12%/5% at 64/128/270MHz. Frequency independent, 15-20% higher conductivity was also noted in tumors compared to muscle tissue over the same frequency range. Strong negative correlation was observed between tissue conductivity and ADC. Whereas permittivity had the strongest discriminatory power at 64 MHz, it became comparable to ADC at 128 MHz and less important than ADC at 270 MHz. Conductivity measurements offered limited advantages in separating cancer from normal tissue beyond what ADC already provided; conversely, permittivity added separation power when added to the discriminant function. The moderately high cancerous tissue permittivity and conductivity impose strong constraints on the capability of MRI-based tissue electrical property measurements. © 2014 Wiley Periodicals, Inc.

  12. Quasi optimal and adaptive sparse grids with control variates for PDEs with random diffusion coefficient

    KAUST Repository

    Tamellini, Lorenzo

    2016-01-05

    In this talk we discuss possible strategies to minimize the impact of the curse of dimensionality effect when building sparse-grid approximations of a multivariate function u = u(y1, ..., yN ). More precisely, we present a knapsack approach , in which we estimate the cost and the error reduction contribution of each possible component of the sparse grid, and then we choose the components with the highest error reduction /cost ratio. The estimates of the error reduction are obtained by either a mixed a-priori / a-posteriori approach, in which we first derive a theoretical bound and then tune it with some inexpensive auxiliary computations (resulting in the so-called quasi-optimal sparse grids ), or by a fully a-posteriori approach (obtaining the so-called adaptive sparse grids ). This framework is very general and can be used to build quasi-optimal/adaptive sparse grids on bounded and unbounded domains (e.g. u depending on uniform and normal random distributions for yn), using both nested and non-nested families of univariate collocation points. We present some theoretical convergence results as well as numerical results showing the efficiency of the proposed approach for the approximation of the solution of elliptic PDEs with random diffusion coefficients. In this context, to treat the case of rough permeability fields in which a sparse grid approach may not be suitable, we propose to use the sparse grids as a control variate in a Monte Carlo simulation.

  13. Retrieval methods of radon-thoron diffusion coefficients over Garhwal Himalayan region

    International Nuclear Information System (INIS)

    Kimothi, Sanjeev; Tomar, Pratiba; Raturi, Ganesh

    2012-01-01

    Radon in the atmosphere is considered to be the most important contributor to the health risk. It comes from the top few meter of the ground. The exhalation rate of radon is one of the most important factors that influence indoor and outdoor radon concentrations. More than 50% of natural radiation doses to the general public are delivered by radon, thoron and their daughter products. The decay products of radon, 218 Po and 214 Po, make it difficult to measure radon amount. These nuclides not only emit alpha particles but also deposit around detective elements. It had been the usual practice to calculate the progeny concentration from the measured gas concentration using an assumed equilibrium factor. For passive measurements of radon and thoron gas, twin-cup dosimeter systems are widely used. This process of progeny concentration estimation involves a lot of uncertainty especially in the case of thoron progeny. But the development of Direct Progeny sensors (DPRS) has solved the long-standing requirement of measuring solely the progeny concentration. Interestingly, progeny dynamics in the indoor environment is rather complex and depends on a number of factors. There is an urgent need of detail survey and comparison of actual methods for the determination of Radon/Thoron diffusion coefficients and a multi-parametric study in indoor environments which will be helpful in establishment of the equilibrium factor of radon and thoron in Indian dwellings. (author)

  14. Optimal estimation of single-particle diffusion coefficients and kinetics of hOgg1 repair protein on DNA

    DEFF Research Database (Denmark)

    Flyvbjerg, Henrik

    How does one optimally determine the diffusion coefficient of a diffusing particle from a single-time-lapse recorded trajectory of the particle? We answer this question with an explicit, unbiased, and practically optimal covariance-based estimator (CVE). This estimator is regression-free and is far...... substrate, the CVE is biased by substrate motion. However, given some long time series and a substrate under some tension, an extended MLE can separate particle diffusion on the substrate from substrate motion in the laboratory frame. This provides benchmarks that allow removal of bias caused by substrate...

  15. Pitch-angle diffusion coefficients from resonant interactions with electrostatic electron cyclotron harmonic waves in planetary magnetospheres

    Directory of Open Access Journals (Sweden)

    A. K. Tripathi

    2011-02-01

    Full Text Available Pitch-angle diffusion coefficients have been calculated for resonant interaction with electrostatic electron cyclotron harmonic (ECH waves in the magnetospheres of Earth, Jupiter, Saturn, Uranus and Neptune. Calculations have been performed at two radial distances of each planet. It is found that observed wave electric field amplitudes in the magnetospheres of Earth and Jupiter are sufficient to put electrons on strong diffusion in the energy range of less than 100 eV. However, for Saturn, Uranus and Neptune, the observed ECH wave amplitude are insufficient to put electrons on strong diffusion at any radial distance.

  16. Soot modeling of counterflow diffusion flames of ethylene-based binary mixture fuels

    KAUST Repository

    Wang, Yu

    2015-03-01

    A soot model was developed based on the recently proposed PAH growth mechanism for C1-C4 gaseous fuels (KAUST PAH Mechanism 2, KM2) that included molecular growth up to coronene (A7) to simulate soot formation in counterflow diffusion flames of ethylene and its binary mixtures with methane, ethane and propane based on the method of moments. The soot model has 36 soot nucleation reactions from 8 PAH molecules including pyrene and larger PAHs. Soot surface growth reactions were based on a modified hydrogen-abstraction-acetylene-addition (HACA) mechanism in which CH3, C3H3 and C2H radicals were included in the hydrogen abstraction reactions in addition to H atoms. PAH condensation on soot particles was also considered. The experimentally measured profiles of soot volume fraction, number density, and particle size were well captured by the model for the baseline case of ethylene along with the cases involving mixtures of fuels. The simulation results, which were in qualitative agreement with the experimental data in the effects of binary fuel mixing on the sooting structures of the measured flames, showed in particular that 5% addition of propane (ethane) led to an increase in the soot volume fraction of the ethylene flame by 32% (6%), despite the fact that propane and ethane are less sooting fuels than is ethylene, which is in reasonable agreement with experiments of 37% (14%). The model revealed that with 5% addition of methane, there was an increase of 6% in the soot volume fraction. The average soot particle sizes were only minimally influenced while the soot number densities were increased by the fuel mixing. Further analysis of the numerical data indicated that the chemical cross-linking effect between ethylene and the dopant fuels resulted in an increase in PAH formation, which led to higher soot nucleation rates and therefore higher soot number densities. On the other hand, the rates of soot surface growth per unit surface area through the HACA mechanism were

  17. Validity of apparent diffusion coefficient hyperpolarized 3He-MRI using MSCT and pulmonary function tests as references

    DEFF Research Database (Denmark)

    Diaz, Sandra; Casselbrant, Ingrid; Piitulainen, Eeva

    2008-01-01

    PURPOSE: To compare apparent diffusion coefficient (ADC) measurements from hyperpolarized (HP) helium ((3)He)-magnetic resonance imaging (MRI) with quantitative data from multislice Computed Tomography (CT) (MSCT) of the whole lungs and pulmonary function tests (PFT). MATERIALS AND METHODS: Twent...

  18. A nonequilibrium simulation method for calculating tracer diffusion coefficients of small solutes in n-alkane liquids and polymers

    NARCIS (Netherlands)

    van der Vegt, N.F.A.; Briels, Willem J.; Wessling, Matthias; Strathmann, H.

    1998-01-01

    The tracer diffusion coefficients of methane in n-alkane liquids of increasing chain length were calculated by measuring the friction from short time nonequilibrium molecular dynamics simulations. The frictional constant was calculated from the exponentially decaying distance between two methane

  19. Evaluations on Profiles of the Eddy Diffusion Coefficients through Simulations of Super Typhoons in the Northwestern Pacific

    Directory of Open Access Journals (Sweden)

    Jimmy Chi Hung Fung

    2016-01-01

    Full Text Available The modeling of the eddy diffusion coefficients (also known as eddy diffusivity in the first-order turbulence closure schemes is important for the typhoon simulations, since the coefficients control the magnitude of the sensible heat flux and the latent heat flux, which are energy sources for the typhoon intensification. Profiles of the eddy diffusion coefficients in the YSU planetary boundary layer (PBL scheme are evaluated in the advanced research WRF (ARW system. Three versions of the YSU scheme (original, K025, and K200 are included in this study. The simulation results are compared with the observational data from track, center sea-level pressure (CSLP, and maximum surface wind speed (MWSP. Comparing with the original version, the K200 improves the averaged mean absolute errors (MAE of track, CSLP, and MWSP by 6.0%, 3.7%, and 23.1%, respectively, while the K025 deteriorates the averaged MAEs of track, CSLP, and MWSP by 25.1%, 19.0%, and 95.0%, respectively. Our results suggest that the enlarged eddy diffusion coefficients may be more suitable for super typhoon simulations.

  20. Cerium heterodiffusion in bcc lanthanum. The influence of the β→γ transformation on diffusion coefficients

    International Nuclear Information System (INIS)

    Fromont, M.

    1976-01-01

    It is shown that neither the dislocations resulting from the phase transformation (closed packed structure-body cubic centered structure), nor the grain boundaries are responsible for the high values of the diffusion coefficients in the b.c.c. structures of the rare earth metals [fr

  1. Measurement of Ferric Ion Diffusion Coefficient in Fricke-Infused Agarose Gel From MR Image Intensity Changes

    National Research Council Canada - National Science Library

    Tseng, Yin-Jiun

    2001-01-01

    .... Our results showed that for a Fricke-agarose gel contained 1mM ammonium ferrous sulfate, 1% agarose, 1mM sodium chloride and 50mM sulfuric acid, its ferric ion diffusion coefficient is 1.31x10(-2)cm(2)h(-1...

  2. The prognostic value of pretreatment tumor apparent diffusion coefficient values in nasopharyngeal carcinoma.

    Science.gov (United States)

    Yan, Dan-Fang; Zhang, Wen-Bao; Ke, Shan-Bao; Zhao, Feng; Yan, Sen-Xiang; Wang, Qi-Dong; Teng, Li-Song

    2017-10-11

    Diffusion-weighted MR imaging (DWI) has increasingly contributed to the management of nasopharyngeal carcinoma (NPC) patients. The objective of this paper was to explore the prognostic significance of apparent diffusion coefficient (ADC) values in 93 NPC patients. This retrospective study included 93 newly diagnosed NPC patients. Pretreatment ADC values were determined and compared with patients' age, gender, alcohol intake, smoking, tumor volume, pathological type, tumor stage, and nodal stage. Using the Kaplan-Meier method, overall survival (OS), local relapse-free survival (LRFS), and distant metastasis-free survival (DMFS) were calculated and the values compared between the low and high ADC groups. Multivariate analysis of ADC values and other 9 clinical parameters was performed using a Cox proportional hazards model to test the independent significance for OS, LRFS and DMFS. The mean ADC value for the initial nasopharyngeal tumors was 0.72 × 10 -3  mm 2 /s (range: 0.48-0.97 × 10 -3  mm 2 /s). There was no significant difference between pretreatment ADCs and patient' gender, age, smoking, alcohol intake, or tumor stage. A significant difference in the ADCs for different N stages (P = 0.022) and correlation with initial tumor volume (r = -0.26, P = 0.012) were observed. In comparison, the ADC value for undifferentiated carcinoma was lower than that for other 3 pathological types. With a median follow-up period of 50 months, the 3-year and 5-year OS rates were 88.2% and 83.3%, respectively, 3-year and 5-year LRFS rates were 93.5% and 93.3%, respectively, and 3-year and 5-year DMFS rates were 83.9% and 83.3%, respectively. Patients with tumor ADC values ≥0.72 × 10 -3  mm 2 /s exhibited longer OS and LRFS periods compared with tumor ADC values values 0.036 and 0.018, respectively. In addition, patients with deaths or recurrences or distant metastasis had significant lower ADC values than those without disease failures. According to a

  3. Quantitative Apparent Diffusion Coefficients in the Characterization of Brain Tumors and Associated Peritumoral Edema

    Energy Technology Data Exchange (ETDEWEB)

    Server, A.; Schellhorn, T.; Nakstad, P.H. (Dept. of Neuroradiology, Div. of Radiology, Ullevaal Univ. Hospital, Univ. of Oslo, Oslo (Norway)); Kulle, B. (Epi-Gen Faculty Div. Akershus Univ. Hospital and Dept. of Biostatistics, Univ. of Oslo, Oslo (Norway)); Maehlen, J.; Kumar, T. (Dept. of Pathology, Ullevaal Univ. Hospital, Univ. of Oslo, Oslo (Norway)); Josefsen, R. (Dept. of Neurosurgery, Ullevaal Univ. Hospital, Univ. of Oslo, Oslo (Norway)); Langberg, C.W. (Cancer Centre, Ullevaal Univ. Hospital, Univ. of Oslo, Oslo (Norway))

    2009-07-15

    Background: Conventional magnetic resonance (MR) imaging has a number of limitations in the diagnosis of the most common intracranial brain tumors, including tumor specification and the detection of tumoral infiltration in regions of peritumoral edema. Purpose: To prospectively assess if diffusion-weighted MR imaging (DWI) could be used to differentiate between different types of brain tumors and to distinguish between peritumoral infiltration in high-grade gliomas, lymphomas, and pure vasogenic edema in metastases and meningiomas. Material and Methods: MR imaging and DWI was performed on 93 patients with newly diagnosed brain tumors: 59 patients had histologically verified high-grade gliomas (37 glioblastomas multiforme, 22 anaplastic astrocytomas), 23 patients had metastatic brain tumors, five patients had primary cerebral lymphomas, and six patients had meningiomas. Apparent diffusion coefficient (ADC) values of tumor (enhancing regions or the solid portion of tumor) and peritumoral edema, and ADC ratios (ADC of tumor or peritumoral edema to ADC of contralateral white matter, ADC of tumor to ADC of peritumoral edema) were compared with the histologic diagnosis. ADC values and ratios of high-grade gliomas, primary cerebral lymphomas, metastases, and meningiomas were compared by using ANOVA and multiple comparisons. Optimal thresholds of ADC values and ADC ratios for distinguishing high-grade gliomas from metastases were determined by receiver operating characteristic (ROC) curve analysis. Results: Statistically significant differences were found for minimum and mean of ADC tumor and ADC tumor ratio values between metastases and high-grade gliomas when including only one factor at a time. Including a combination of in total four parameters (mean ADC tumor, and minimum, maximum and mean ADC tumor ratio) resulted in sensitivity, specificity, positive (PPV), and negative predictive values (NPV) of 72.9, 82.6, 91.5, and 54.3% respectively. In the ROC curve analysis

  4. Quantitative Apparent Diffusion Coefficients in the Characterization of Brain Tumors and Associated Peritumoral Edema

    International Nuclear Information System (INIS)

    Server, A.; Schellhorn, T.; Nakstad, P.H.; Kulle, B.; Maehlen, J.; Kumar, T.; Josefsen, R.; Langberg, C.W.

    2009-01-01

    Background: Conventional magnetic resonance (MR) imaging has a number of limitations in the diagnosis of the most common intracranial brain tumors, including tumor specification and the detection of tumoral infiltration in regions of peritumoral edema. Purpose: To prospectively assess if diffusion-weighted MR imaging (DWI) could be used to differentiate between different types of brain tumors and to distinguish between peritumoral infiltration in high-grade gliomas, lymphomas, and pure vasogenic edema in metastases and meningiomas. Material and Methods: MR imaging and DWI was performed on 93 patients with newly diagnosed brain tumors: 59 patients had histologically verified high-grade gliomas (37 glioblastomas multiforme, 22 anaplastic astrocytomas), 23 patients had metastatic brain tumors, five patients had primary cerebral lymphomas, and six patients had meningiomas. Apparent diffusion coefficient (ADC) values of tumor (enhancing regions or the solid portion of tumor) and peritumoral edema, and ADC ratios (ADC of tumor or peritumoral edema to ADC of contralateral white matter, ADC of tumor to ADC of peritumoral edema) were compared with the histologic diagnosis. ADC values and ratios of high-grade gliomas, primary cerebral lymphomas, metastases, and meningiomas were compared by using ANOVA and multiple comparisons. Optimal thresholds of ADC values and ADC ratios for distinguishing high-grade gliomas from metastases were determined by receiver operating characteristic (ROC) curve analysis. Results: Statistically significant differences were found for minimum and mean of ADC tumor and ADC tumor ratio values between metastases and high-grade gliomas when including only one factor at a time. Including a combination of in total four parameters (mean ADC tumor, and minimum, maximum and mean ADC tumor ratio) resulted in sensitivity, specificity, positive (PPV), and negative predictive values (NPV) of 72.9, 82.6, 91.5, and 54.3% respectively. In the ROC curve analysis

  5. A method for estimating the diffuse attenuation coefficient (KdPAR)from paired temperature sensors

    Science.gov (United States)

    Read, Jordan S.; Rose, Kevin C.; Winslow, Luke A.; Read, Emily K.

    2015-01-01

    A new method for estimating the diffuse attenuation coefficient for photosynthetically active radiation (KdPAR) from paired temperature sensors was derived. We show that during cases where the attenuation of penetrating shortwave solar radiation is the dominant source of temperature changes, time series measurements of water temperatures at multiple depths (z1 and z2) are related to one another by a linear scaling factor (a). KdPAR can then be estimated by the simple equation KdPAR ln(a)/(z2/z1). A suggested workflow is presented that outlines procedures for calculating KdPAR according to this paired temperature sensor (PTS) method. This method is best suited for conditions when radiative temperature gains are large relative to physical noise. These conditions occur frequently on water bodies with low wind and/or high KdPARs but can be used for other types of lakes during time periods of low wind and/or where spatially redundant measurements of temperatures are available. The optimal vertical placement of temperature sensors according to a priori knowledge of KdPAR is also described. This information can be used to inform the design of future sensor deployments using the PTS method or for campaigns where characterizing sub-daily changes in temperatures is important. The PTS method provides a novel method to characterize light attenuation in aquatic ecosystems without expensive radiometric equipment or the user subjectivity inherent in Secchi depth measurements. This method also can enable the estimation of KdPAR at higher frequencies than many manual monitoring programs allow.

  6. Using Directional Diffusion Coefficients for Nonlinear Diffusion Acceleration of the First Order SN Equations in Near-Void Regions

    Energy Technology Data Exchange (ETDEWEB)

    Schunert, Sebastian; Hammer, Hans; Lou, Jijie; Wang, Yaqi; Ortensi, Javier; Gleicher, Frederick; Baker, Benjamin; DeHart, Mark; Martineau, Richard

    2016-11-01

    The common definition of the diffusion coeffcient as the inverse of three times the transport cross section is not compat- ible with voids. Morel introduced a non-local tensor diffusion coeffcient that remains finite in voids[1]. It can be obtained by solving an auxiliary transport problem without scattering or fission. Larsen and Trahan successfully applied this diffusion coeffcient for enhancing the accuracy of diffusion solutions of very high temperature reactor (VHTR) problems that feature large, optically thin channels in the z-direction [2]. It is demonstrated that a significant reduction of error can be achieved in particular in the optically thin region. Along the same line of thought, non-local diffusion tensors are applied modeling the TREAT reactor confirming the findings of Larsen and Trahan [3]. Previous work of the authors have introduced a flexible Nonlinear-Diffusion Acceleration (NDA) method for the first order S N equations discretized with the discontinuous finite element method (DFEM), [4], [5], [6]. This NDA method uses a scalar diffusion coeffcient in the low-order system that is obtained as the flux weighted average of the inverse transport cross section. Hence, it su?ers from very large and potentially unbounded diffusion coeffcients in the low order problem. However, it was noted that the choice of the diffusion coeffcient does not influence consistency of the method at convergence and hence the di?usion coeffcient is essentially a free parameter. The choice of the di?usion coeffcient does, however, affect the convergence behavior of the nonlinear di?usion iterations. Within this work we use Morel’s non-local di?usion coef- ficient in the aforementioned NDA formulation in lieu of the flux weighted inverse of three times the transport cross section. The goal of this paper is to demonstrate that significant en- hancement of the spectral properties of NDA can be achieved in near void regions. For testing the spectral properties of the NDA

  7. Diffusion behavior of anion in hardened low-heat portland cement paste containing fly ash. Dependence of effective diffusion coefficient on pore structure

    International Nuclear Information System (INIS)

    Chida, Taiji; Yoshida, Takahiro

    2012-01-01

    In the sub-surface disposal system, the closely packed concrete layer is expected the low diffusivity to retard the migration of radionuclides. Low-heat portland cement containing 30 wt% fly ash (FAC) is a candidate cement material for the construction of sub-surface repository because of its high dense structure and its resistance to cracking. Previously, we reported that FAC has lower diffusivity than Ordinary Portland Cement (OPC) for acetic acid and iodine. However, the mechanism for low diffusivity of FAC was not clear. In this study, the diffusion of multiple trace ions (chlorine, bromine and iodine) in hardened cement pastes was examined by through-diffusion experiments. The effective diffusion coefficients, D e , of the trace ions for hardened OPC cement pastes were on the order of 10 -12 m 2 s -1 for trace ions, and D e for hardened FAC cement pastes were on the order of 10 -13 m 2 s -1 for chlorine, 10 -14 m 2 s -1 for bromine and 10 -15 m 2 s -1 for iodine. Additionally, the pore size distribution and porosity of FAC changed to more closely packed structure for 13 months by the pozzolanic reaction, and the pore size distribution of FAC (mainly 3-10 nm) were an order of magnitude smaller than that of OPC. These results suggest that the low diffusivity of FAC is based on the continuous change in the pore structure and the nano-scale pore size retarding the migration of trace ions. (author)

  8. Determination of the diffusion coefficients of iron and chromium in Pb17Li at 500 deg C

    International Nuclear Information System (INIS)

    Simon, N.; Flament, T.; Terlain, A.

    1992-01-01

    The diffusion of the dissolved metallic species in a liquid metal towards the boundary layer is one of the elementary steps of the overall mass transfer process induced by thermal gradient. This phenomenon is very probably the limiting step in the mass transfer of martensitic Fe-Cr steels in the presence of Pb17Li liquid eutectic alloy. For estimating diffusion flux, the diffusion coefficients of iron and chromium in Pb17Li are needed but are not known. Consequently these data have been determined in CEA laboratory by measuring metal loss of cylindrical specimens after rotation at 500 deg C in Pb17Li for several hours and applying the first Fick diffusion law in the boundary layer whose the thickness has been previously determined by EISENBERG. After a description of the experimental device, the results are presented and discussed

  9. Determination of Diffusion Coefficients and Activation Energy of Selected Organic Liquids using Reversed-Flow Gas Chromatographic Technique

    International Nuclear Information System (INIS)

    Khalisanni Khalid; Rashid Atta Khan; Sharifuddin Mohd Zain

    2012-01-01

    Evaporation of vaporize organic liquid has ecological consequences when the compounds are introduced into both freshwater and marine environments through industrial effluents, or introduced directly into the air from industrial unit processes such as bioreactors and cooling towers. In such cases, a rapid and simple method are needed to measure physicochemical properties of the organic liquids. The Reversed-Flow Gas Chromatography (RF-GC) sampling technique is an easy, fast and accurate procedure. It was used to measure the diffusion coefficients of vapors from liquid into a carrier gas and at the same time to determine the rate coefficients for the evaporation of the respective liquid. The mathematical expression describing the elution curves of the samples peaks was derived and used to calculate the respective parameters for the selected liquid pollutants selected such as methanol, ethanol, 1-propanol, 1-butanol, n-pentane, n-hexane, n-heptane and n-hexadecane, evaporating into the carrier gas of nitrogen. The values of diffusion coefficients found were compared with those calculated theoretically or reported in the literature. The values of evaporation rate were used to determine the activation energy of respective samples using Arrhenius equation. An interesting finding of this work is by using an alternative mathematical analysis based on equilibrium at the liquid-gas interphase, the comparison leads to profound agreement between theoretical values of diffusion coefficients and experimental evidence. (author)

  10. Change in mean transit time, apparent diffusion coefficient, and cerebral blood volume during pediatric diabetic ketoacidosis treatment.

    Science.gov (United States)

    Vavilala, Monica S; Marro, Ken I; Richards, Todd L; Roberts, Joan S; Curry, Parichat; Pihoker, Catherine; Bradford, Heidi; Shaw, Dennis

    2011-11-01

    Cerebral edema is a devastating complication of pediatric diabetic ketoacidosis. We examined measures describing potential causes of whole brain and regional brain edema (mean transit time, apparent diffusion coefficient, and relative cerebral blood volume) during treatment of diabetic ketoacidosis in children. Prospective observational study. Regional children's hospital. None. After Institutional Review Board approval, children admitted with diabetic ketoacidosis (pH 300 mg/dL, and ketosis) underwent two serial paired contrast-enhanced (gadolinium) and diffusion magnetic resonance imaging scans. Change in whole brain and regional (frontal lobe, occipital lobe, and basal ganglia) mean transit time, apparent diffusion coefficient, and relative cerebral blood volume between the two time periods (12-24 hrs) and (36-72 hrs) after start of insulin treatment (time 0) were determined. Thirteen children (median age, 10.3 ± 1.1 yrs; 7 female) with diabetic ketoacidosis were examined. Overall, whole brain and regional mean transit time decreased from time 1 (first magnetic resonance imaging after time 0) to time 2 (second magnetic resonance imaging after time 0) by 51% ± 59% (p = .01), without differences between the brain regions examined. Whole brain apparent diffusion coefficient increased by 4.7% ± 3.4% (p = .001), without differences between the brain regions examined. There was no change in relative cerebral blood volume for the whole brain and for the three brain regions examined. In this study, whole brain mean transit time decreased and apparent diffusion coefficient increased, suggesting a vasogenic process between the two study periods during diabetic ketoacidosis treatment.

  11. Measuring the Local Diffusion Coefficient with H.E.S.S. Observations of Very High-Energy Electrons

    Energy Technology Data Exchange (ETDEWEB)

    Hooper, Dan [Fermilab; Linden, Tim [Ohio State U., CCAPP

    2017-11-20

    The HAWC Collaboration has recently reported the detection of bright and spatially extended multi-TeV gamma-ray emission from Geminga, Monogem, and a handful of other nearby, middle-aged pulsars. The angular profile of the emission observed from these pulsars is surprising, in that it implies that cosmic-ray diffusion is significantly inhibited within ~25 pc of these objects, compared to the expectations of standard Galactic diffusion models. This raises the important question of whether the diffusion coefficient in the local interstellar medium is also low, or whether it is instead better fit by the mean Galactic value. Here, we utilize recent observations of the cosmic-ray electron spectrum (extending up to ~20 TeV) by the H.E.S.S. Collaboration to show that the local diffusion coefficient cannot be as low as it is in the regions surrounding Geminga and Monogem. Instead, we conclude that cosmic rays efficiently diffuse through the bulk of the local interstellar medium. Among other implications, this further supports the conclusion that pulsars significantly contribute to the observed positron excess.

  12. Measurement of diffusion coefficient of thallium ion in H2O and D2O systems at different concentrations

    International Nuclear Information System (INIS)

    Das, A.; Changdar, S.N.

    1992-01-01

    Sliding cell method, developed in our laboratory, has been used to measure the inter diffusion coefficient of thallium ion in thallous sulphate solution over a wide concentration range using both water and heavy water as solvent at 35degC. The results have been analysed from the point of view of both ion-ion and ion-solvent interactions. The comparison of the diffusivities of the same ion in D 2 O and H 2 O electrolyte solutions at the same temperature indicate that the addition of salt affects the two solvent differently. (author). 8 refs., 1 fig., 1 tab

  13. ICP-MS measurement of silver diffusion coefficient in graphite IG-110 between 1048K and 1284K

    Science.gov (United States)

    Carter, L. M.; Seelig, J. D.; Brockman, J. D.; Robertson, J. D.; Loyalka, S. K.

    2018-01-01

    Silver-110m has been shown to permeate intact silicon carbide and pyrolytic carbon coating layers of the TRISO fuel particles during normal High Temperature Gas-Cooled Reactor (HTGR) operational conditions. The diffusion coefficients for silver in graphite IG-110 measured using a release method designed to simulate HTGR conditions of high temperature and flowing helium in the temperature range 1048-1253 K are reported. The measurements were made using spheres milled from IG-110 graphite that were infused with silver using a pressure vessel technique. The Ag diffusion was measured using a time release technique with an ICP-MS instrument for detection. The results of this work are:

  14. Initial-boundary value problems for multi-term time-fractional diffusion equations with x-dependent coefficients

    OpenAIRE

    Li, Zhiyuan; Huang, Xinchi; Yamamoto, Masahiro

    2018-01-01

    In this paper, we discuss an initial-boundary value problem (IBVP) for the multi-term time-fractional diffusion equation with x-dependent coefficients. By means of the Mittag-Leffler functions and the eigenfunction expansion, we reduce the IBVP to an equivalent integral equation to show the unique existence and the analyticity of the solution for the equation. Especially, in the case where all the coefficients of the time-fractional derivatives are non-negative, by the Laplace and inversion L...

  15. Vapor pressures and activity coefficients of binary mixtures of 1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide with acetonitrile and tetrahydrofuran

    International Nuclear Information System (INIS)

    Safarov, Javid; Geppert-Rybczyńska, Monika; Hassel, Egon; Heintz, Andreas

    2012-01-01

    Highlights: ► A new apparatus for the determination of VLE is presented. ► The first vapor pressures for binary mixtures containing aprotic solvents in IL are reported. ► Calculated activity coefficients and osmotic coefficients reveal a strong non-ideal behavior. ► A more detailed study of the highly diluted IL concentration range is necessary to test the Debye–Hückel law. - Abstract: A new apparatus for the determination of VLE has been constructed which works for absolute pressure measurements as well as for measuring differential pressures. The first results obtained are (vapor + liquid) equilibria (VLE) of binary mixtures containing acetonitrile or tetrahydrofuran and the ionic liquid (IL) 1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide [EMIm][NTf2] by using the absolute pressures method. VLE measurements were carried out over the whole concentration range at four different temperatures between 293.15 K and 313.15 K. Activity coefficients (γ 1 ) of the solvents in [EMIm][NTf2] and their osmotic coefficients (φ 1 ) have been determined from the VLE data.

  16. Coherent quantum transport in disordered systems: II. Temperature dependence of carrier diffusion coefficients from the time-dependent wavepacket diffusion method

    International Nuclear Information System (INIS)

    Zhong, Xinxin; Zhao, Yi; Cao, Jianshu

    2014-01-01

    The time-dependent wavepacket diffusion method for carrier quantum dynamics (Zhong and Zhao 2013 J. Chem. Phys. 138 014111), a truncated version of the stochastic Schrödinger equation/wavefunction approach that approximately satisfies the detailed balance principle and scales well with the size of the system, is applied to investigate the carrier transport in one-dimensional systems including both the static and dynamic disorders on site energies. The predicted diffusion coefficients with respect to temperature successfully bridge from band-like to hopping-type transport. As demonstrated in paper I (Moix et al 2013 New J. Phys. 15 085010), the static disorder tends to localize the carrier, whereas the dynamic disorder induces carrier dynamics. For the weak dynamic disorder, the diffusion coefficients are temperature-independent (band-like property) at low temperatures, which is consistent with the prediction from the Redfield equation, and a linear dependence of the coefficient on temperature (hopping-type property) only appears at high temperatures. In the intermediate regime of dynamic disorder, the transition from band-like to hopping-type transport can be easily observed at relatively low temperatures as the static disorder increases. When the dynamic disorder becomes strong, the carrier motion can follow the hopping-type mechanism even without static disorder. Furthermore, it is found that the memory time of dynamic disorder is an important factor in controlling the transition from the band-like to hopping-type motions. (paper)

  17. The effect on the radon diffusion coefficient of long-term exposure of waterproof membranes to various degradation agents

    International Nuclear Information System (INIS)

    Navratilova Rovenska, Katerina

    2014-01-01

    Waterproofing, usually made of bitumen or polymers with various additives, is used to protect buildings mainly against dampness, but also against radon transported from the soil beneath the building. The radon diffusion coefficient is a material property which is considered to be strongly influenced by the inner structure (chemical composition, crystallinity) of a measured sample. We have used this parameter together with measurements of mechanical properties (hardness, tensile strength, elongation at break, etc.) and FTIR spectroscopy has been used in order to describe the changes in material properties induced by long-term degradation. This paper summarizes the results of radon diffusion coefficient measurements of waterproof materials exposed to radon, soil bacteria, high temperature and combinations of these factors. We have discovered changes as high as 83 % have been discovered compared to virgin samples. (authors)

  18. An improved experimental scheme to measure self-diffusion coefficients of biomolecules with an advantageous use of radiation damping

    Energy Technology Data Exchange (ETDEWEB)

    Krishnan, V. V. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States). Biology and Biotechnology Research Program; Thornton, Kevin H. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States). Biology and Biotechnology Research Program; Cosman, Monique [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States). Biology and Biotechnology Research Program

    1999-03-19

    An improved nuclear magnetic resonance (NMR) experimental scheme to measure self-diffusion coefficients of biomolecules in 95% H2O using pulsed-magnetic-field gradients is presented. The radiation damping of water, which deleteriously effects the quality of the spectra in high-field NMR, is advantageously used in reducing the water signal. Finally, the enhancements of the new sequence, designated BPP-SED, a novel combination of BPP-LED (bipolar-gradient-pulse pair longitudinal eddy current delay) and SED (selective echo dephasing) is demonstrated by measuring self-diffusion coefficients of dilute protein samples (0.5 mM) in limited volumes (250 μl).

  19. Convergence of the Euler-Maruyama method for multidimensional SDEs with discontinuous drift and degenerate diffusion coefficient.

    Science.gov (United States)

    Leobacher, Gunther; Szölgyenyi, Michaela

    2018-01-01

    We prove strong convergence of order [Formula: see text] for arbitrarily small [Formula: see text] of the Euler-Maruyama method for multidimensional stochastic differential equations (SDEs) with discontinuous drift and degenerate diffusion coefficient. The proof is based on estimating the difference between the Euler-Maruyama scheme and another numerical method, which is constructed by applying the Euler-Maruyama scheme to a transformation of the SDE we aim to solve.

  20. Electron drift velocity and longitudinal diffusion coefficient of an electron swarm in hydrogen at elevated swarm energies

    International Nuclear Information System (INIS)

    Blevin, H.A.; Fletcher, J.; Hunter, S.R.

    1976-02-01

    A study of the photons produced at electron-molecule excitation collisions has been used to obtain information on the behaviour of an electron swarm moving through a neutral gas under the influence of a uniform electric field. Specifically values have been obtained for the electron drift velocity and the longitudinal diffusion coefficients under equilibrium swarm conditions, i.e. remote from any electrode. (author)

  1. The electron drift velocity and longitudinal diffusion coefficient of an electron swarm in hydrogen at elevated swarm energies

    International Nuclear Information System (INIS)

    Blevin, H.A.; Fletcher, J.; Hunter, S.R.

    1976-01-01

    A study of the photons produced at electron-molecule excitation collisions has been used to obtain information on the behaviour of an electron swarm moving through a neutral gas under the influence of a uniform electric field. Specifically, values have been obtained for the electron drift velocity and the longitudinal diffusion coefficients under equilibrium swarm conditions, i.e. remote from any electrode. (author)

  2. Osmotic coefficients of binary mixtures of four ionic liquids with ethanol or water at T = (313.15 and 333.15) K

    International Nuclear Information System (INIS)

    Calvar, Noelia; Gonzalez, Begona; Dominguez, Angeles; Macedo, Eugenia A.

    2009-01-01

    Measurements of osmotic coefficients of BmimCl (1-butyl-3-methylimidazolium chloride) and HmimCl (1-hexyl-3-methylimidazolium chloride) with ethanol and EmimEtSO 4 (1-ethyl-3-methylimidazolium ethylsulfate) and EmpyEtSO 4 (1-ethyl-3-methylpyridinium ethylsulfate) with water at T = (313.15 and 333.15) K are reported in this work. Vapour pressure and activity results of the studied binary systems are obtained from experimental measurements. The results for the osmotic coefficients are correlated using the extended Pitzer model modified by Archer and the modified NRTL (MNRTL) model. The standard deviations obtained with both models are also given. The parameters obtained with the extended Pitzer model of Archer are used to calculate the mean molal activity coefficients

  3. The Complete Solution of Fick's Second Law of Diffusion with Time-dependent Diffusion Coefficient and Surface Concentration

    DEFF Research Database (Denmark)

    Mejlbro, Leif

    1996-01-01

    Fick's Second Law of Diffusion with time-dependent diffusioncoefficient and surface concentration is solved. Mimicking the classicalsolution, special time-dependent surface concentration functions areconsidered. These models are used in giving estimates of the lifetimeof the structure, when the c...... the concrete cover is given, as well as estimatesof the thickness of the concrete cover, when the expected lifetime is given.*Note: Book tilte: Durability of Concrete in Saline Environment...

  4. Multi-charge-state molecular dynamics and self-diffusion coefficient in the warm dense matter regime

    Science.gov (United States)

    Fu, Yongsheng; Hou, Yong; Kang, Dongdong; Gao, Cheng; Jin, Fengtao; Yuan, Jianmin

    2018-01-01

    We present a multi-ion molecular dynamics (MIMD) simulation and apply it to calculating the self-diffusion coefficients of ions with different charge-states in the warm dense matter (WDM) regime. First, the method is used for the self-consistent calculation of electron structures of different charge-state ions in the ion sphere, with the ion-sphere radii being determined by the plasma density and the ion charges. The ionic fraction is then obtained by solving the Saha equation, taking account of interactions among different charge-state ions in the system, and ion-ion pair potentials are computed using the modified Gordon-Kim method in the framework of temperature-dependent density functional theory on the basis of the electron structures. Finally, MIMD is used to calculate ionic self-diffusion coefficients from the velocity correlation function according to the Green-Kubo relation. A comparison with the results of the average-atom model shows that different statistical processes will influence the ionic diffusion coefficient in the WDM regime.

  5. Diffusion coefficients of some cations in a mud rock sample from the Bure site

    Energy Technology Data Exchange (ETDEWEB)

    Melkior, T.; Yahiaoui, S.; Thoby, D.; Barthes, V. [CEA Grenoble, 38 (France)

    2005-07-01

    Clayey materials exhibit attractive features as barrier for radioactive waste confinement, such as low permeability, high retention capacity, long-term stability, etc. The low permeability of such materials often makes diffusion the principal mechanism for migration of radionuclides potentially released from waste canisters. Therefore, diffusion of dissolved species has been extensively investigated in clay-based porous media. The purpose of this work is to investigate the diffusion of alkaline cations (Li{sup +}, Na{sup +}, K{sup +}, Rb{sup +} and Cs{sup +}) in a mud-rock sample from the Bure site (Meuse/Haute-Marne, France). (authors)

  6. Optical absorption coefficient and minority carrier diffusion length measurements in low-cost silicon solar cell material

    Energy Technology Data Exchange (ETDEWEB)

    Swimm, R.T.; Dumas, K.A.

    1982-11-01

    The optical absorption coefficient of silicon solar cell material grown by three low-cost growth methods was measured in the wavelength interval 0.8< or =lambda< or =1.0 ..mu..m, the wavelength region of interest in surface photovoltage measurements of the minority carrier diffusion length. The square root of the absorption coefficient was found to vary linearly with photon energy over the wavelengths studied, and the measured data agree with a linear empirical fit to within 0.5% RMS. The absorption coefficients obtained are slightly lower than those reported by Runyan, with the greatest disagreement at long wavelengths. Minority carrier diffusion lengths computed using the present absorption coefficients are approximately 16% greater than those calculated using Runyan's data. Excellent sample-to-sample agreement within and between lots indicates that for two of the growth methods studied, material quality as judged by optical properties has not been sacrificed by the use of low-cost growth methods. Samples grown by the third growth method studied showed measurably poorer optical quality.

  7. Calculation of diffusion coefficient of long chain molecules using molecular dynamics

    Science.gov (United States)

    Chakraborty, Tanmoy; Hens, Abhiram; Kulashrestha, Shashank; Chandra Murmu, Naresh; Banerjee, Priyabrata

    2015-05-01

    Molecular dynamics (MD) is a powerful tool for calculating several thermo-physical properties of wide range of materials. In this study, the diffusivities (D) of two widely used long chain molecules MHA and ODT are calculated at various temperatures using MD simulations coupled with Einstein relationship. Four different kinds of forcefields COMPASS, UFF, CVFF and PCFF are employed in the MD simulation and the results are compared. Diffusivity values are evaluated in a humid environment in presence of water molecules.

  8. Analysis of the utility of diffusion-weighted MRI and apparent diffusion coefficient values in distinguishing central nervous system toxoplasmosis from lymphoma

    Energy Technology Data Exchange (ETDEWEB)

    Schroeder, Paul C.; Donovan Post, M. Judith; Bruce-Gregorios, Jocelyn [University of Miami, Jackson Memorial Hospital, Miami, FL (United States); Oschatz, Elizabeth; Stadler, Alfred; Thurnher, Majda M. [Medical University of Vienna, Department of Radiology Neuroradiology Section, Vienna (Austria)

    2006-10-15

    Toxoplasmosis and lymphoma are common lesions of the central nervous system in patients with AIDS. It is often difficult to distinguish between these lesions both clinically and radiographically. Previous research has demonstrated restricted diffusion within cerebral lymphomas and bacterial abscesses. However, little work has been done to evaluate the diffusion characteristics of toxoplasmosis lesions. This study was designed to explore further the utility of diffusion-weighted imaging (DWI) and apparent diffusion coefficient (ADC) maps and values in making the distinction between toxoplasmosis and lymphoma. The magnetic resonance imaging (MRI) studies of 36 patients, including 22 with toxoplasmosis (all of whom had AIDS) and 14 with lymphoma (8 of whom had AIDS), at two institutions were reviewed retrospectively. The characteristics of the lesions on DWI were evaluated, and the ADC ratios of the lesions were calculated and compared. There was significant overlap of the ADC ratios of toxoplasma and lymphoma, most notably in the intermediate (1.0-1.6) range. There was variability in ADC ratios even among different lesions in the same patient. In only a minority of the lymphoma patients were the ADC ratios low enough to suggest the correct diagnosis. Our study showed that toxoplasmosis exhibits a wide spectrum of diffusion characteristics with ADC ratios which have significant overlap with those of lymphoma. Therefore, in the majority of patients, ADC ratios are not definitive in making the distinction between toxoplasmosis and lymphoma. (orig.)

  9. Analysis of the utility of diffusion-weighted MRI and apparent diffusion coefficient values in distinguishing central nervous system toxoplasmosis from lymphoma

    International Nuclear Information System (INIS)

    Schroeder, Paul C.; Donovan Post, M. Judith; Bruce-Gregorios, Jocelyn; Oschatz, Elizabeth; Stadler, Alfred; Thurnher, Majda M.

    2006-01-01

    Toxoplasmosis and lymphoma are common lesions of the central nervous system in patients with AIDS. It is often difficult to distinguish between these lesions both clinically and radiographically. Previous research has demonstrated restricted diffusion within cerebral lymphomas and bacterial abscesses. However, little work has been done to evaluate the diffusion characteristics of toxoplasmosis lesions. This study was designed to explore further the utility of diffusion-weighted imaging (DWI) and apparent diffusion coefficient (ADC) maps and values in making the distinction between toxoplasmosis and lymphoma. The magnetic resonance imaging (MRI) studies of 36 patients, including 22 with toxoplasmosis (all of whom had AIDS) and 14 with lymphoma (8 of whom had AIDS), at two institutions were reviewed retrospectively. The characteristics of the lesions on DWI were evaluated, and the ADC ratios of the lesions were calculated and compared. There was significant overlap of the ADC ratios of toxoplasma and lymphoma, most notably in the intermediate (1.0-1.6) range. There was variability in ADC ratios even among different lesions in the same patient. In only a minority of the lymphoma patients were the ADC ratios low enough to suggest the correct diagnosis. Our study showed that toxoplasmosis exhibits a wide spectrum of diffusion characteristics with ADC ratios which have significant overlap with those of lymphoma. Therefore, in the majority of patients, ADC ratios are not definitive in making the distinction between toxoplasmosis and lymphoma. (orig.)

  10. Monte Carlo simulation of diffuse attenuation coefficient in presence of non uniform profiles

    Digital Repository Service at National Institute of Oceanography (India)

    Desa, E.S.; Desai, R.G.P.; Desa, B.A.E.

    This paper presents a Monte Carlo simulation of the vertical depth structure of the downward attenuation coefficient (K sub(d)), and the irradiance reflectance (R) for a given profile of chlorophyll. The results are in quantitaive agreement...

  11. Measuring the ratio of aqueous diffusion coefficients between 6Li +Cl - and 7Li +Cr - by osmometry

    Science.gov (United States)

    Fritz, Steven J.

    1992-10-01

    Osmotic equilibrium is a singular occurrence in the evolution of an osmotic cell because at this event the net solution flux is zero such that -J w · V¯w = J s · V¯s. At this juncture, the diffusion coefficient of the solute through the membrane (ω) equals the solute flux ( Js) divided by the osmotic pressure (ΔΠ). Because the solute permeability coefficient (ω) is related to the Fickian diffusion coefficient ( D) through the gas constant, temperature, and the membrane's thickness and tortuosity, the ratio of ω values for individual isotopic species equals the ratio of D values for the same isotopic components. A 0.9450 molal LiCl solution was placed within sealed dialysis tubing and osmoted against a kilogram of deionized water at 22°C. Osmotic equilibrium occurred at 164 ± 10 min. The ratio of ω6Li +Cl -/ω7Li +Cl - was measured to be 1.011 ± 0.003 - a value close to the square root of the mass ratio between 7LiCl and 6LiCl (= 1.012) as calculated by Graham's Law. The measured diffusion coefficient ratio was used to predict the degree of hyperfiltration-induced fractionation of Li isotopes as a function of membrane ideality. When a membrane's σ exceeds 0.95 (as is likely for low-porosity shales) the 6Li /7Li ratio on the high-pressure side of the membrane can theoretically vary by more than 0.0017.

  12. Effect of porous structure of catalyst layer on effective oxygen diffusion coefficient in polymer electrolyte fuel cell

    Science.gov (United States)

    Inoue, Gen; Kawase, Motoaki

    2016-09-01

    It is important to reduce the oxygen diffusion resistance through PEFC porous electrode, because it is the key to reduce the PEFC cost. However, the gas diffusion coefficient of CL is lower than MPL in spite of framework consisted of same carbon blacks. In this study, in order to understand the reasons of the lower gas diffusion performance of CL, the relationship between a carbon black agglomerate structure and ionomer adhesion condition is evaluated by a numerical analysis with an actual reconstructed structure and a simulated structure. As a result, the gas diffusion property of CL strongly depends on the ionomer adhesion shape. In the case of adhesion shape with the same curvature of ionomer interface, each pore can not be connected enough. So the pore tortuosity increases. Moreover, in the case of existence of inefficient large pores formed by carbon black agglomerate and ununiformly coated ionomer, the gas diffusion performance decrease rapidly. As the measurement values in actual CL are almost equal to that with model structure with inefficient large pores. These characteristics can be confirmed by actual cross-section image obtained by FIB-SEM.

  13. A new technique to measure fission-product diffusion coefficients in UO2 fuel

    International Nuclear Information System (INIS)

    Hocking, W.H.; Verrall, R.A.; Bushby, S.J.

    1999-01-01

    This paper describes a new out-reactor technique for the measurement of fission-product diffusion rates in UO 2 . The technique accurately simulates in-reactor fission-fragment effects: a thermal diffusion that is due to localized mixing in the fission track, radiation-enhanced diffusion that is due to point-defect creation by fission fragments, and bubble resolution. The technique utilizes heavy-ion accelerators - low energy (40 keV to 1 MeV) for fission-product implantation, high energy (72 MeV) to create fission-fragment damage effects, and secondary ion mass spectrometry (SIMS) for measuring the depth profile of the implanted species. Preliminary results are presented from annealing tests (not in the 72 MeV ion flux) at 1465 deg. C and 1650 deg. C at low and high concentrations of fission products. (author)

  14. Intraparticle diffusion coefficient of lithium on granulated adsorbent of manganese oxide in seawater

    International Nuclear Information System (INIS)

    Miyai, Yoshitaka; Kanoh, Hirofumi; Feng, Qi; Ooi, Kenta

    1995-01-01

    Five kinds of manganese-oxide adsorbent granulated with different particle sizes were prepared using polyvinyl chloride (PVC) as a binder. Rates of lithium adsorption on the adsorbents were measured in lithium-enriched seawater ([Li]=3.1 mg·dm -3 ) by a batch method. The intraparticle diffusivities (D p 's) of lithium were evaluated in terms of the model of pore diffusion with a Freundrich-type adsorption isotherm. The D p values were about 2 x 10 -6 cm·s -1 and slightly dependent on particle size. The D p values were also evaluated using column adsorption data. The calculated values (about 4 x 10 -6 cm·s -1 ) agreed comparatively well with those derived from the batch adsorption data. The agreement suggests that the intraparticle diffusion is a rate-determining step in column adsorption at space velocity above 200 h -1 . (author)

  15. Homotopy perturbation transform method for pricing under pure diffusion models with affine coefficients

    Directory of Open Access Journals (Sweden)

    Claude Rodrigue Bambe Moutsinga

    2018-01-01

    Full Text Available Most existing multivariate models in finance are based on diffusion models. These models typically lead to the need of solving systems of Riccati differential equations. In this paper, we introduce an efficient method for solving systems of stiff Riccati differential equations. In this technique, a combination of Laplace transform and homotopy perturbation methods is considered as an algorithm to the exact solution of the nonlinear Riccati equations. The resulting technique is applied to solving stiff diffusion model problems that include interest rates models as well as two and three-factor stochastic volatility models. We show that the present approach is relatively easy, efficient and highly accurate.

  16. Study on the Interaction Coefficients in PR Equation with vdW Mixing Rules for HFC and HC Binary Mixtures

    Science.gov (United States)

    Chen, Jian-Xin; Hu, Peng; Chen, Ze-Shao

    2008-12-01

    The Peng-Robinson equation of state with the van der Waals mixing rules was used to correlate vapor-liquid equilibrium (VLE) data for HFC/HC, HFC/HFC, and HC/HC binary mixtures. The interaction parameter k ij was obtained for every binary mixture. It was assumed that k ij has contributions from the two components, and each component has its own constant contribution factor k i for the mixture, and the values of k ij indicate the degree in difference of properties between the two components. Therefore, the interaction parameters k ij is proposed as: k ij = k i - k j . The values of the mixing factor k i for Hydrofluorocarbons (HFCs) and Hydrocarbons (HCs), including propane, isobutane, n-butane, R23, R32, R125, R143a, R134a, R152a, R227ea R236fa, R236ea, and R245fa, were obtained by least-square fitting. In total, 39 refrigerant binary mixtures were analyzed on the basis of this method, and the results showed good agreement with experimental data. The overall average absolute deviations of pressure and vapor mole fraction are 1.3 % and 0.0089, respectively.

  17. Sensitivity of Rabbit Ventricular Action Potential and Ca2+ Dynamics to Small Variations in Membrane Currents and Ion Diffusion Coefficients

    Directory of Open Access Journals (Sweden)

    Yuan Hung Lo

    2013-01-01

    Full Text Available Little is known about how small variations in ionic currents and Ca2+ and Na+ diffusion coefficients impact action potential and Ca2+ dynamics in rabbit ventricular myocytes. We applied sensitivity analysis to quantify the sensitivity of Shannon et al. model (Biophys. J., 2004 to 5%–10% changes in currents conductance, channels distribution, and ion diffusion in rabbit ventricular cells. We found that action potential duration and Ca2+ peaks are highly sensitive to 10% increase in L-type Ca2+ current; moderately influenced by 10% increase in Na+-Ca2+ exchanger, Na+-K+ pump, rapid delayed and slow transient outward K+ currents, and Cl− background current; insensitive to 10% increases in all other ionic currents and sarcoplasmic reticulum Ca2+ fluxes. Cell electrical activity is strongly affected by 5% shift of L-type Ca2+ channels and Na+-Ca2+ exchanger in between junctional and submembrane spaces while Ca2+-activated Cl−-channel redistribution has the modest effect. Small changes in submembrane and cytosolic diffusion coefficients for Ca2+, but not in Na+ transfer, may alter notably myocyte contraction. Our studies highlight the need for more precise measurements and further extending and testing of the Shannon et al. model. Our results demonstrate usefulness of sensitivity analysis to identify specific knowledge gaps and controversies related to ventricular cell electrophysiology and Ca2+ signaling.

  18. On the air-filled effective porosity parameter of Rogers and Nielson's (1991) bulk radon diffusion coefficient in unsaturated soils.

    Science.gov (United States)

    Saâdi, Zakaria

    2014-05-01

    The radon exhalation rate at the earth's surface from soil or rock with radium as its source is the main mechanism behind the radon activity concentrations observed in both indoor and outdoor environments. During the last two decades, many subsurface radon transport models have used Rogers and Nielson's formula for modeling the unsaturated soil bulk radon diffusion coefficient. This formula uses an "air-filled effective porosity" to account for radon adsorption and radon dissolution in the groundwater. This formula is reviewed here, and its hypotheses are examined for accuracy in dealing with subsurface radon transport problems. The author shows its limitations by comparing one dimensional steady-state analytical solutions of the two-phase (air/water) transport equation (Fick's law) with Rogers and Nielson's formula. For radon diffusion-dominated transport, the calculated Rogers and Nielson's radon exhalation rate is shown to be unrealistic as it is independent of the values of the radon adsorption and groundwater dissolution coefficients. For convective and diffusive transport, radon exhalation rates calculated using Fick's law and this formula agree only for high values of gas-phase velocity and groundwater saturation. However, these conditions are not usually met in most shallow subsurface environments where radon migration takes place under low gas phase velocities and low water saturation.

  19. Experimental Determination of Drug Diffusion Coefficients in Unstirred Aqueous Environments by Temporally Resolved Concentration Measurements

    DEFF Research Database (Denmark)

    Di Cagno, Massimiliano Pio; Clarelli, Fabrizio; Vabenø, Jon

    2018-01-01

    of a substance during spontaneous migration of molecules, followed by standard mathematical treatment of the data in order to solve Fick's law of diffusion. This method is extremely sensitive and results in highly reproducible data. The technique was also employed to verify the influence of the environmental...

  20. Influence of vibrations and rotations of diatomic molecules on their physical properties: II. Refractive index, reactivity and diffusion coefficients

    International Nuclear Information System (INIS)

    Sharipov, Alexander S; Loukhovitski, Boris I; Starik, Alexander M

    2016-01-01

    The influence of the excitation of vibrational and rotational states of diatomic molecules (H 2 , N 2 , O 2 , NO, OH, CO, CH, HF and HCl) on refractive index, reactivity and transport coefficients was analyzed by using ab initio calculated data on the effective state-specific dipole moment and static polarizability obtained in the preceding paper of the present series. It has been revealed that, for non-polar molecules, the excitation both of vibrational and rotational degrees of freedom increases the averaged polarizability and, as a consequence, the refractive index. Meanwhile, for polar molecules, the effect of molecule excitation is more complex: it can either increase or decrease the refractive index. It was also shown that the excitation of molecules slightly influences the rate constants of barrierless chemical reactions between neutral particles; whereas, for ion–molecule reactions, this effect can be more pronounced. Analysis of the variation of diffusion coefficients, taking into account the effect of molecule excitation both on the collision diameter and on the well depth of intermolecular potential, exhibited that, for non-polar molecules, the effect associated with the change of collision diameter prevails. However, for polar molecules, the effect of the excitation of vibrational states on the well depth of intermolecular potential can compensate or even exceed the decrease of diffusion coefficient due to the averaged collision diameter rise. (paper)

  1. Low-frequency Raman spectra of sub- and supercritical CO2: qualitative analysis of the diffusion coefficient behavior.

    Science.gov (United States)

    Idrissi, A; Longelin, S; Damay, P; Leclercq, F

    2005-09-01

    We report the results of the low-frequency Raman experiments on CO(2) which were carried out in a wide density range, along the liquid-gas coexistence curve in a temperature range of 293-303 K, and on the critical isochore of 94.4 cm(3) mol(-1) in a temperature range of 304-315 K. In our approach, the qualitative behavior of the diffusion coefficient D is predicted, assuming the following: first, that the low-frequency Raman spectra can be interpreted in terms of the translation rotation motions; second, that the random force could be replaced by the total force to calculate the friction coefficient; and finally, that the Einstein frequency is associated with the position of the maximum of the low-frequency Raman spectrum. The results show that the diffusion coefficient increases along the coexistence curve, and its values are almost constant on the critical isochore. The predicted values reproduce qualitatively those obtained by other techniques. The values of D were also calculated by molecular-dynamics simulation and they qualitatively reproduce the behavior of D.

  2. Meta-Analysis of the Correlation between Apparent Diffusion Coefficient and Standardized Uptake Value in Malignant Disease

    Directory of Open Access Journals (Sweden)

    Shengming Deng

    2017-01-01

    Full Text Available The objective of this meta-analysis is to explore the correlation between the apparent diffusion coefficient (ADC on diffusion-weighted MR and the standard uptake value (SUV of 18F-FDG on PET/CT in patients with cancer. Databases such as PubMed (MEDLINE included, EMBASE, and Cochrane Database of Systematic Review were searched for relevant original articles that explored the correlation between SUV and ADC in English. After applying Fisher’s r-to-z transformation, correlation coefficient (r values were extracted from each study and 95% confidence intervals (CIs were calculated. Sensitivity and subgroup analyses based on tumor type were performed to investigate the potential heterogeneity. Forty-nine studies were eligible for the meta-analysis, comprising 1927 patients. Pooled r for all studies was −0.35 (95% CI: −0.42–0.28 and exhibited a notable heterogeneity (I2 = 78.4%; P < 0.01. In terms of the cancer type subgroup analysis, combined correlation coefficients of ADC/SUV range from −0.12 (lymphoma, n = 5 to −0.59 (pancreatic cancer, n = 2. We concluded that there is an average negative correlation between ADC and SUV in patients with cancer. Higher correlations were found in the brain tumor, cervix carcinoma, and pancreas cancer. However, a larger, prospective study is warranted to validate these findings in different cancer types.

  3. Effective transport coefficients in PEM fuel cell catalyst and gas diffusion layers: Beyond Bruggeman approximation

    Energy Technology Data Exchange (ETDEWEB)

    Das, Prodip K. [Department of Mechanical and Mechatronics Engineering, University of Waterloo, 200 University Avenue West, Waterloo, ON (Canada); Institute for Fuel Cell Innovation, National Research Council, Vancouver, BC (Canada); Li, Xianguo [Department of Mechanical and Mechatronics Engineering, University of Waterloo, 200 University Avenue West, Waterloo, ON (Canada); Liu, Zhong-Sheng [Institute for Fuel Cell Innovation, National Research Council, Vancouver, BC (Canada)

    2010-09-15

    The Bruggeman approximation has widely been used for estimating the effective conductivity and diffusivity of both the catalyst and gas diffusion layers of polymer electrolyte membrane (PEM) fuel cells. This approximation is based on the Bruggeman's Effective Medium Theory [Bruggeman D. Berechnung verschiedener physikalischer konstanten von heterogenen substanzen. Ann Phys (Leipzig) 1935;24:636-79], which provides empirical correlation for the effective properties of a composite system. Since it is an empirical correlation, a unique correlation based on the Bruggeman approximation does not always hold for the PEM fuel cell effective properties. Rather, the Bruggeman correlation is a cell specific and experiment dependent correlation that depends on structure, phase composition, water saturation, experimental parameters, etc. Further, this correlation needs to be combined with other correlations to estimate the effective diffusivities. In this article, a set of mathematical formulations has been proposed for the effective transport properties in both the catalyst and gas diffusion layers of a PEM fuel cell. The effective conductivity and diffusivity expressions are derived from the mathematical formulations of the Hashin Coated Sphere model [Hashin Z. The elastic moduli of heterogeneous materials. J Appl Mech 1962;29:143-50], which provides an identical mathematical foundation for each of these effective properties rather than an empirical correlation and avoid to use of multiple correlations together. The present model formulations agree well with the results available in literature for the limiting case. Hence, the proposed formulations for the effective transport properties will be a useful estimating tool in the numerical modeling of PEM fuel cells. (author)

  4. Determination of water diffusion coefficient by gamma radiation and thermal shock

    International Nuclear Information System (INIS)

    Crausse, P.; Lemarchand, D.

    1985-01-01

    Mass transfer coefficient of water in a porous material (baked clay) is determined by gamma ray attenuation (from a Cs135 source) and thermal shock. Water content is found higher by thermal shock, difference obtained between the two methods is discussed. 7 refs [fr

  5. Validity of apparent diffusion coefficient hyperpolarized 3He-MRI using MSCT and pulmonary function tests as references

    DEFF Research Database (Denmark)

    Diaz, Sandra; Casselbrant, Ingrid; Piitulainen, Eeva

    2008-01-01

    -seven subjects, 22 with established emphysema and 5 with preclinical emphysema defined by PFT criteria, were examined with HP (3)He-MRI and MSCT. Mean age was 55 (+/-12) years, 18 female and 9 male. Mean ADC from (3)He-MRI was compared with emphysema index (EI), 15th percentile and mean lung density (MLD) values......PURPOSE: To compare apparent diffusion coefficient (ADC) measurements from hyperpolarized (HP) helium ((3)He)-magnetic resonance imaging (MRI) with quantitative data from multislice Computed Tomography (CT) (MSCT) of the whole lungs and pulmonary function tests (PFT). MATERIALS AND METHODS: Twenty...... from MSCT. Both mean ADC and MSCT data were compared to PFT, especially percent of predicted diffusing capacity of carbon monoxide (%predicted DLCO), using Pearson's correlation test. RESULTS: Mean ADC and standard deviation values were 0.392+/-0.119 cm(2)/s for the established emphysema group and 0...

  6. Method for the determination of oxygen consumption rates and diffusion coefficients in multicellular spheroids

    OpenAIRE

    Mueller-Klieser, W.

    1984-01-01

    A method has been developed for the quantitative evaluation of oxygen tension (PO2) distributions in multicellular spheroids measured with O2-sensitive microelectrodes. The experimental data showed that multicellular tumor spheroids in stirred growth media were characterized by a diffusion-depleted zone surrounding the spheroids. This zone was elicited by an unstirred layer of medium next to the spheroid leading to a continuous decrease in the PO2 values from the bulk medium towards the spher...

  7. Calculation and analysis of the mobility and diffusion coefficient of thermal electrons in methane/air premixed flames

    KAUST Repository

    Bisetti, Fabrizio

    2012-12-01

    Simulations of ion and electron transport in flames routinely adopt plasma fluid models, which require transport coefficients to compute the mass flux of charged species. In this work, the mobility and diffusion coefficient of thermal electrons in atmospheric premixed methane/air flames are calculated and analyzed. The electron mobility is highest in the unburnt region, decreasing more than threefold across the flame due to mixture composition effects related to the presence of water vapor. Mobility is found to be largely independent of equivalence ratio and approximately equal to 0.4m 2V -1s -1 in the reaction zone and burnt region. The methodology and results presented enable accurate and computationally inexpensive calculations of transport properties of thermal electrons for use in numerical simulations of charged species transport in flames. © 2012 The Combustion Institute.

  8. Relationship between Secchi depth and the diffuse light attenuation coefficient in Danish estuaries

    DEFF Research Database (Denmark)

    Murray, Ciarán; Markager, Stiig

    Analyis of temporal and spatial variation in the in the relationship between light attenuation and Secchi depth in Danish monitoring data There can be found timeseries of Secchi depth measurements in Danish waters which extend relatively far back in time. The Secchi depth measurement is therefore...... useful in that it allows comparison of present conditions with these older observations. An empirical inverse relationship between Secchi depth and light attenuation coefficient, Kd, has traditionally been used to estimate the light attenuation coefficient from Secchi depth measurements. However, studies...... have shown that the assumption of a constant inverse relationship between Kd and Secchi depth does not hold. The authors have analyzed measurements of Secchi depth and light attenuation from Danish monitoring data. The data used in our investigation was collected over a continuous period from 1986...

  9. Albedo and flux extinction coefficient of impure snow for diffuse shortwave radiation

    Science.gov (United States)

    Choudhury, B. J.; Mo, T.; Wang, J. R.; Chang, A. T. C.

    1981-01-01

    Impurities enter a snowpack as a result of fallout of scavenging by falling snow crystals. Albedo and flux extinction coefficient of soot contaminated snowcovers were studied using a two stream approximation of the radiative transfer equation. The effect of soot was calculated by two methods: independent scattering by ice grains and impurities and average refractive index for ice grains. Both methods predict a qualitatively similar effect of soot; the albedo is decreased and the extinction coefficient is increased compared to that for pure snow in the visible region; the infrared properties are largely unaffected. Quantitatively, however, the effect of soot is more pronounced in the average refractive index method. Soot contamination provides a qualitative explanation for several snow observations.

  10. Theoretical and experimental comparison of the Soret coefficient for water-methanol and water-ethanol binary mixtures

    DEFF Research Database (Denmark)

    Saghir, MZ; Jiang, CG; Derawi, Samer

    2004-01-01

    In multicomponent. mixtures, a much richer variety of phenomena can occur than in Simple (single-component) fluids. Natural convection in single-component. fluids is due to buoyancy forces caused by temperature gradients. In multicomponent mixtures, buoyancy forces may also be caused...... by concentration gradients. Because natural convection, molecular diffusion, and thermal conduction have different relaxation time scales, a wide variety of resulting convective motions and heat, and mass distributions might occur. In some fluid mixtures such as water-ethanol system, for instance, ethanol diffuses...... much more slowly than heat, and because of this difference in time scales oscillatory convection might occur. In a multocomponent mixture, the total molar flux consists of two parts: the convective molar flux and the diffusive molar flux (resulting from the difference between the component, velocity...

  11. Nonsuppressing normal thymus on chemical-shift MR imaging and anterior mediastinal lymphoma: differentiation with diffusion-weighted MR imaging by using the apparent diffusion coefficient.

    Science.gov (United States)

    Priola, Adriano Massimiliano; Priola, Sandro Massimo; Gned, Dario; Giraudo, Maria Teresa; Veltri, Andrea

    2018-04-01

    To prospectively evaluate usefulness of the apparent diffusion coefficient (ADC) in differentiating anterior mediastinal lymphoma from nonsuppressing normal thymus on chemical-shift MR, and to look at the relationship between patient age and ADC. Seventy-three young subjects (25 men, 48 women; age range, 9-29 years), who underwent chemical-shift MR and diffusion-weighted MR were divided into a normal thymus group (group A, 40 subjects), and a lymphoma group (group B, 33 patients). For group A, all subjects had normal thymus with no suppression on opposed-phase chemical-shift MR. Two readers measured the signal intensity index (SII) and ADC. Differences in SII and ADC between groups were tested using t-test. ADC was correlated with age using Pearson correlation coefficient. Mean SII±standard deviation was 2.7±1.8% for group A and 2.2±2.4% for group B, with no significant difference between groups (P=.270). Mean ADC was 2.48±0.38x10 -3 mm 2 /s for group A and 1.24±0.23x10 -3 mm 2 /s for group B. A significant difference between groups was found (Pnormal thymus at visual assessment • ADC is useful for distinguishing nonsuppressing normal thymus from mediastinal lymphoma • ADC is more accurate than transverse-diameter and surface-area in this discrimination • ADC of normal thymus is age dependent and increases with increasing age.

  12. Activation Energies for Diffusion in Pure Metals and Concentrated Binary Alloys

    Energy Technology Data Exchange (ETDEWEB)

    Toth, L. E.; Searcy, A. W.

    1963-07-16

    A modification of Le Claire's microscopic model for self-diffusion is developed in a form suitable for prediction of activation energies for diffusion in disordered substitutional solutions as well as in pure metals. Bonding is considered as a localized interaction, and the energy of bonding between atoms of different types is taken as the arithmetic mean of the energies in the pure elements. The activation energies for vacancy formation and migration in substitutional alloys are shown to depend on the empirical constants developed for self-diffusion when the equations are adjusted for the mole fractions of the two elements. The calculated results for alloy diffusion usually agree with the experimental values to within the experimental errors.

  13. Zn diffusion in binary base of light Mg-Al alloys

    Czech Academy of Sciences Publication Activity Database

    Čermák, Jiří; Stloukal, Ivo

    2007-01-01

    Roč. 263, - (2007), s. 165-170 ISSN 1012-0386. [D&T ’06 Seminar on Diffusion and Thermodynamics of Materials /9./. Brno, 13.09.2006-15.09.2006] R&D Projects: GA ČR GA106/05/2115 Institutional research plan: CEZ:AV0Z20410507 Keywords : magnesium * AZ91 * zinc diffusion in Mg-Al alloys Subject RIV: BJ - Thermodynamics Impact factor: 0.483, year: 2005

  14. Drag force, diffusion coefficient, and electric mobility of small particles. II. Application.

    Science.gov (United States)

    Li, Zhigang; Wang, Hai

    2003-12-01

    We propose a generalized treatment of the drag force of a spherical particle due to its motion in a laminar fluid media. The theory is equally applicable to analysis of particle diffusion and electric mobility. The focus of the current analysis is on the motion of spherical particles in low-density gases with Knudsen number Kn>1. The treatment is based on the gas-kinetic theory analysis of drag force in the specular and diffuse scattering limits obtained in a preceding paper [Z. Li and H. Wang, Phys. Rev. E., 68, 061206 (2003)]. Our analysis considers the influence of van der Waals interactions on the momentum transfer upon collision of a gas molecule with the particle and expresses this influence in terms of an effective, reduced collision integral. This influence is shown to be significant for nanosized particles. In the present paper, the reduced collision integral values are obtained for specular and diffuse scattering, using a Lennard-Jones-type potential energy function suitable for the interactions of a gas molecule with a particle. An empirical formula for the momentum accommodation function, used to determine the effective, reduced collision integral, is obtained from available experimental data. The resulting treatment is shown to be accurate for interpreting the mobility experiments for particles as small as approximately 1 nm in radius. The treatment is subsequently extended to the entire range of the Knudsen number, following a semiempirical, gas-kinetic theory analysis. We demonstrate that the proposed formula predicts very well Millikan's oil-droplet experiments [R. A. Millikan, Philos. Mag. 34, 1 (1917); Phys. Rev. 22, 1 (1923)]. The rigorous theoretical foundation of the proposed formula in the Kn>1 limit makes the current theory far more general than the semiempirical Stokes-Cunningham formula in terms of the particle size and condition of the fluid and, therefore, more attractive than the Stokes-Cunningham formula.

  15. Combined inverse-forward artificial neural networks for fast and accurate estimation of the diffusion coefficients of cartilage based on multi-physics models

    NARCIS (Netherlands)

    Arbabi, V.; Pouran, B.; Weinans, H.H.; Zadpoor, A.A.

    2016-01-01

    Analytical and numerical methods have been used to extract essential engineering parameters such as elastic modulus, Poisson's ratio, permeability and diffusion coefficient from experimental data in various types of biological tissues. The major limitation associated with analytical techniques is

  16. Diffusion weighted imaging of the normal breast: reproducibility of apparent diffusion coefficient measurements and variation with menstrual cycle and menopausal status

    International Nuclear Information System (INIS)

    O'Flynn, Elizabeth A.M.; Morgan, Veronica A.; Giles, Sharon L.; de Souza, Nandita M.

    2012-01-01

    To establish the reproducibility of apparent diffusion coefficient (ADC) measurements in normal fibroglandular breast tissue and to assess variation in ADC values with phase of the menstrual cycle and menopausal status. Thirty-one volunteers (13 premenopausal, 18 postmenopausal) underwent magnetic resonance twice (interval 11-22 days) using diffusion-weighted MRI. ADC total and a perfusion-insensitive ADC high (omitting b = 0) were calculated. Reproducibility and inter-observer variability of mean ADC values were assessed. The difference in mean ADC values between the two phases of the menstrual cycle and the postmenopausal breast were evaluated. ADC total and ADC high showed good reproducibility (r% = 17.6, 22.4). ADC high showed very good inter-observer agreement (kappa = 0.83). The intraclass correlation coefficients (ICC) were 0.93 and 0.91. Mean ADC values were significantly lower in the postmenopausal breast (ADC total 1.46 ± 0.3 x 10 -3 mm 2 /s, ADC high 1.33 ± 0.3 x 10 -3 mm 2 /s) compared with the premenopausal breast (ADC total 1.84 ± 0.26 x 10 -3 mm 2 /s, ADC high 1.77 ± 0.26 x 10 -3 mm 2 /s; both P total P = 0.2, ADC high P = 0.24) or between postmenopausal women taking or not taking oestrogen supplements (ADC total P = 0.6, ADC high P = 0.46). ADC values in fibroglandular breast tissue are reproducible. Lower ADC values within the postmenopausal breast may reduce diffusion-weighted contrast and have implications for accurately detecting tumours. (orig.)

  17. Diffusion weighted imaging of the normal breast: reproducibility of apparent diffusion coefficient measurements and variation with menstrual cycle and menopausal status

    Energy Technology Data Exchange (ETDEWEB)

    O' Flynn, Elizabeth A.M.; Morgan, Veronica A.; Giles, Sharon L. [Cancer Research UK and ESPSRC Cancer Imaging Centre, Clinical Magnetic Resonance Group, Surrey (United Kingdom); deSouza, Nandita M. [Royal Marsden NHS Foundation Trust, Clinical Magnetic Resonance Group, Institute of Cancer Research, Surrey (United Kingdom)

    2012-07-15

    To establish the reproducibility of apparent diffusion coefficient (ADC) measurements in normal fibroglandular breast tissue and to assess variation in ADC values with phase of the menstrual cycle and menopausal status. Thirty-one volunteers (13 premenopausal, 18 postmenopausal) underwent magnetic resonance twice (interval 11-22 days) using diffusion-weighted MRI. ADC{sub total} and a perfusion-insensitive ADC{sub high} (omitting b = 0) were calculated. Reproducibility and inter-observer variability of mean ADC values were assessed. The difference in mean ADC values between the two phases of the menstrual cycle and the postmenopausal breast were evaluated. ADC{sub total} and ADC{sub high} showed good reproducibility (r% = 17.6, 22.4). ADC{sub high} showed very good inter-observer agreement (kappa = 0.83). The intraclass correlation coefficients (ICC) were 0.93 and 0.91. Mean ADC values were significantly lower in the postmenopausal breast (ADC{sub total} 1.46 {+-} 0.3 x 10{sup -3} mm{sup 2}/s, ADC{sub high} 1.33 {+-} 0.3 x 10{sup -3} mm{sup 2}/s) compared with the premenopausal breast (ADC{sub total} 1.84 {+-} 0.26 x 10{sup -3} mm{sup 2}/s, ADC{sub high} 1.77 {+-} 0.26 x 10{sup -3} mm{sup 2}/s; both P < 0.001). No significant difference was seen in ADC values in relation to menstrual cycle (ADC{sub total} P = 0.2, ADC{sub high} P = 0.24) or between postmenopausal women taking or not taking oestrogen supplements (ADC{sub total} P = 0.6, ADC{sub high} P = 0.46). ADC values in fibroglandular breast tissue are reproducible. Lower ADC values within the postmenopausal breast may reduce diffusion-weighted contrast and have implications for accurately detecting tumours. (orig.)

  18. Apparent diffusion coefficient of breast cancer and normal fibroglandular tissue in diffusion-weighted imaging: the effects of menstrual cycle and menopausal status.

    Science.gov (United States)

    Kim, Jin You; Suh, Hie Bum; Kang, Hyun Jung; Shin, Jong Ki; Choo, Ki Seok; Nam, Kyung Jin; Lee, Seok Won; Jung, Young Lae; Bae, Young Tae

    2016-05-01

    The purpose of this study was to investigate prospectively whether the apparent diffusion coefficients (ADCs) of both breast cancer and normal fibroglandular tissue vary with the menstrual cycle and menopausal status. Institutional review board approval was obtained, and informed consent was obtained from each participant. Fifty-seven women (29 premenopausal, 28 postmenopausal) with newly diagnosed breast cancer underwent diffusion-weighted imaging twice (interval 12-20 days) before surgery. Two radiologists independently measured ADC of breast cancer and normal contralateral breast tissue, and we quantified the differences according to the phases of menstrual cycle and menopausal status. With normal fibroglandular tissue, ADC was significantly lower in postmenopausal than in premenopausal women (P = 0.035). In premenopausal women, ADC did not differ significantly between proliferative and secretory phases in either breast cancer or normal fibroglandular tissue (P = 0.969 and P = 0.519, respectively). In postmenopausal women, no significant differences were found between ADCs measured at different time intervals in either breast cancer or normal fibroglandular tissue (P = 0.948 and P = 0.961, respectively). The within-subject variability of the ADC measurements was quantified using the coefficient of variation (CV) and was small: the mean CVs of tumor ADC were 2.90 % (premenopausal) and 3.43 % (postmenopausal), and those of fibroglandular tissue ADC were 4.37 % (premenopausal) and 2.55 % (postmenopausal). Both intra- and interobserver agreements were excellent for ADC measurements, with intraclass correlation coefficients in the range of 0.834-0.974. In conclusion, the measured ADCs of breast cancer and normal fibroglandular tissue were not affected significantly by menstrual cycle, and the measurements were highly reproducible both within and between observers.

  19. No correlation between glucose metabolism and apparent diffusion coefficient in diffuse large B-cell lymphoma: A PET/CT and DW-MRI study

    Energy Technology Data Exchange (ETDEWEB)

    Wu Xingchen, E-mail: Xingchen.Wu@uta.fi [Department of Oncology, Tampere University Hospital, Tampere (Finland); Medical Imaging Centre, Department of Radiology, Tampere University Hospital, Tampere (Finland); Korkola, Pasi [Medical Imaging Centre, Department of Nuclear Medicine, Tampere University Hospital, Tampere (Finland); Pertovaara, Hannu [Department of Oncology, Tampere University Hospital, Tampere (Finland); Eskola, Hannu [Medical Imaging Centre, Department of Radiology, Tampere University Hospital, Tampere (Finland); Department of Biomedical Engineering, Tampere University of Technology, Tampere (Finland); Jaervenpaeae, Ritva [Medical Imaging Centre, Department of Radiology, Tampere University Hospital, Tampere (Finland); Kellokumpu-Lehtinen, Pirkko-Liisa [Department of Oncology, Tampere University Hospital, Tampere (Finland); Medical School, University of Tampere (Finland)

    2011-08-15

    Purpose: Both positron emission tomography/computed tomography (PET/CT) and diffusion-weighted magnetic resonance imaging (DW-MRI) are oncologic feasible techniques for evaluating the malignancy of tumors. Standardized uptake value (SUV) is a marker of tumor glucose metabolism detected by PET/CT. Apparent diffusion coefficient (ADC) measured by DWI can provide information about tissue cellularity. The aim of the study was to evaluate the correlation between SUV and ADC in untreated diffuse large B-cell lymphoma (DLBCL). Materials and methods: Fifteen pre-therapy patients with histologically proven DLBCL underwent PET/CT and DWI examinations within two days. Tumor glucose metabolism was evaluated by the maximum and mean SUV (SUV{sub max} and SUV{sub mean}) on the PET/CT images. The mean ADC value was measured directly on the parametric ADC maps. Results: In total, 28 lymphoma lesions with best match PET/CT and DWI were identified and evaluated. The mean SUV{sub max} and SUV{sub mean} were 16.8 and 11.1, respectively; the mean ADC was 0.74 x 10{sup -3} mm{sup 2}/s. There was no correlation between the mean ADC and the SUV{sub max} or SUV{sub mean}. Conclusion: SUV determined from PET/CT and ADC value measured from DWI are different indices for the diagnosis of tumor malignancy, they may provide complimentary functional information of tumor tissue.

  20. Thermodynamic scaling and corresponding states for the self-diffusion coefficient of non-conformal soft-sphere fluids.

    Science.gov (United States)

    Rodríguez-López, Tonalli; Moreno-Razo, J Antonio; del Río, Fernando

    2013-03-21

    In this work, we explore transport properties of a special type of repulsive spheres that exhibit remarkable scaling of their thermodynamic properties. In order to accomplish that we propose a new way to derive and express effective hard-sphere diameters for transport properties of simple fluids. The procedure relies on mapping the system's transport properties, in the low density limit, to the hard-sphere fluid. We have chosen a set of soft-sphere systems characterised by a well-defined variation of their softness. These systems represent an extension of the repulsive Lennard-Jones potential widely used in statistical mechanics of fluids and are an accurate representation of the effective repulsive potentials of real systems. The self-diffusion coefficient of the soft-sphere fluids is obtained by equilibrium molecular dynamics. The soft-sphere collision integrals of different systems are shown to follow quite simple relationships between each other. These collision integrals are incorporated, through the definition of the effective hard-sphere diameter, in the resulting equation for the self-diffusion coefficient. The approach followed exhibits a density rescaling that leads to a single master curve for all systems and temperatures. The scaling is carried through to the level of the mean-squared displacement.

  1. Prediction and validation of diffusion coefficients in a model drug delivery system using microsecond atomistic molecular dynamics simulation and vapour sorption analysis.

    Science.gov (United States)

    Forrey, Christopher; Saylor, David M; Silverstein, Joshua S; Douglas, Jack F; Davis, Eric M; Elabd, Yossef A

    2014-10-14

    Diffusion of small to medium sized molecules in polymeric medical device materials underlies a broad range of public health concerns related to unintended leaching from or uptake into implantable medical devices. However, obtaining accurate diffusion coefficients for such systems at physiological temperature represents a formidable challenge, both experimentally and computationally. While molecular dynamics simulation has been used to accurately predict the diffusion coefficients, D, of a handful of gases in various polymers, this success has not been extended to molecules larger than gases, e.g., condensable vapours, liquids, and drugs. We present atomistic molecular dynamics simulation predictions of diffusion in a model drug eluting system that represent a dramatic improvement in accuracy compared to previous simulation predictions for comparable systems. We find that, for simulations of insufficient duration, sub-diffusive dynamics can lead to dramatic over-prediction of D. We present useful metrics for monitoring the extent of sub-diffusive dynamics and explore how these metrics correlate to error in D. We also identify a relationship between diffusion and fast dynamics in our system, which may serve as a means to more rapidly predict diffusion in slowly diffusing systems. Our work provides important precedent and essential insights for utilizing atomistic molecular dynamics simulations to predict diffusion coefficients of small to medium sized molecules in condensed soft matter systems.

  2. Experimental investigation of stability and extinction coefficient of Al2O3–CuO binary nanoparticles dispersed in ethylene glycol–water mixture for low-temperature direct absorption solar collectors

    International Nuclear Information System (INIS)

    Menbari, Amir; Alemrajabi, Ali Akbar; Ghayeb, Yousef

    2016-01-01

    Highlights: • Viscosity and optical properties of binary nanofluids are investigated. • Effective parameters on stability of binary nanofluids are studied. • At optimal stability condition viscosity and absorbency of nanofluids are optimum. • The extinction coefficient of binary nanofluids is sum of its components ones. - Abstract: Binary nanofluids form a new class of nanofluids made through the simultaneous dispersion of two dissimilar nanoparticles in a base fluid. Two different nanoparticles may behave differently from their constituent components. Given the wide applications of binary nanofluids in a variety of fields, it is important to gain an understanding of the best stability conditions for binary nanofluids. In this work, the effects of such nanofluid properties as pH, surfactant (SHMP) concentration, and ultrasonic time are experimentally investigated on the stability of binary nanofluids. For this purpose, binary nanofluids are prepared using the two-step method. Two dissimilar nanoparticles, i.e. CuO and γ-Al 2 O 3 nanoparticles are dispersed in ethylene glycol and in the ethylene glycol–water mixture to form the desired nanofluids. Results show that at optimal stability conditions, viscosity and absorbency of the nanofluids are minimum and maximum, respectively. Also, the stability optimal parameters of binary nanofluids are found to be different from their corresponding values for each individual nanofluid. The extinction coefficient of the binary nanofluid is found to be approximately equal to the sum of those of the constituent components. Finally, the extinction coefficient of the nanoparticles dispersed in the mixture of ethylene glycol–water is determined to be greater than that of ethylene glycol.

  3. Estimation of the effective intercellular diffusion coefficient in cell monolayers coupled by gap junctions

    DEFF Research Database (Denmark)

    Olesen, Niels Erik; Hofgaard, Johannes P; von Holstein-Rathlou, Niels-Henrik

    2012-01-01

    A recently developed dye-based assay to study gap junction permeability is analysed. The assay is based on electroporation of dye into a large number of connexin 43 expressing cells, grown to confluency on electrically conductive slides. The subsequent intercellular spread of dye to non-electropo......A recently developed dye-based assay to study gap junction permeability is analysed. The assay is based on electroporation of dye into a large number of connexin 43 expressing cells, grown to confluency on electrically conductive slides. The subsequent intercellular spread of dye to non......-electroporated parts of the monolayer enables estimation of the intercellular coupling. So far, the extent of dye spread has been analyzed in qualitative terms only and not in a manner based directly on the physics of the underlying diffusion process....

  4. Assessment of treatment response by total tumor volume and global apparent diffusion coefficient using diffusion-weighted MRI in patients with metastatic bone disease: a feasibility study.

    Directory of Open Access Journals (Sweden)

    Matthew D Blackledge

    Full Text Available We describe our semi-automatic segmentation of whole-body diffusion-weighted MRI (WBDWI using a Markov random field (MRF model to derive tumor total diffusion volume (tDV and associated global apparent diffusion coefficient (gADC; and demonstrate the feasibility of using these indices for assessing tumor burden and response to treatment in patients with bone metastases. WBDWI was performed on eleven patients diagnosed with bone metastases from breast and prostate cancers before and after anti-cancer therapies. Semi-automatic segmentation incorporating a MRF model was performed in all patients below the C4 vertebra by an experienced radiologist with over eight years of clinical experience in body DWI. Changes in tDV and gADC distributions were compared with overall response determined by all imaging, tumor markers and clinical findings at serial follow up. The segmentation technique was possible in all patients although erroneous volumes of interest were generated in one patient because of poor fat suppression in the pelvis, requiring manual correction. Responding patients showed a larger increase in gADC (median change = +0.18, range = -0.07 to +0.78 × 10(-3 mm2/s after treatment compared to non-responding patients (median change = -0.02, range = -0.10 to +0.05 × 10(-3 mm2/s, p = 0.05, Mann-Whitney test, whereas non-responding patients showed a significantly larger increase in tDV (median change = +26%, range = +3 to +284% compared to responding patients (median change = -50%, range = -85 to +27%, p = 0.02, Mann-Whitney test. Semi-automatic segmentation of WBDWI is feasible for metastatic bone disease in this pilot cohort of 11 patients, and could be used to quantify tumor total diffusion volume and median global ADC for assessing response to treatment.

  5. Cohesive energy and structural parameters of binary oxides of groups IIA and IIIB from diffusion quantum Monte Carlo

    Science.gov (United States)

    Santana, Juan A.; Krogel, Jaron T.; Kent, Paul R. C.; Reboredo, Fernando A.

    2016-05-01

    We have applied the diffusion quantum Monte Carlo (DMC) method to calculate the cohesive energy and the structural parameters of the binary oxides CaO, SrO, BaO, Sc2O3, Y2O3, and La2O3. The aim of our calculations is to systematically quantify the accuracy of the DMC method to study this type of metal oxides. The DMC results were compared with local, semi-local, and hybrid Density Functional Theory (DFT) approximations as well as with experimental measurements. The DMC method yields cohesive energies for these oxides with a mean absolute deviation from experimental measurements of 0.18(2) eV, while with local, semi-local, and hybrid DFT approximations, the deviation is 3.06, 0.94, and 1.23 eV, respectively. For lattice constants, the mean absolute deviations in DMC, local, semi-local, and hybrid DFT approximations are 0.017(1), 0.07, 0.05, and 0.04 Å, respectively. DMC is a highly accurate method, outperforming the DFT approximations in describing the cohesive energies and structural parameters of these binary oxides.

  6. Evaluation of Solid-Solution Hardening in Several Binary Alloy Systems Using Diffusion Couples Combined with Nanoindentation

    Science.gov (United States)

    Kadambi, Sourabh B.; Divya, V. D.; Ramamurty, U.

    2017-10-01

    Analysis of solid-solution hardening (SSH) in alloys requires the synthesis of large composition libraries and the measurement of strength or hardness from these compositions. Conventional methods of synthesis and testing, however, are not efficient and high-throughput approaches have been developed in the past. In the present study, we use a high-throughput combinatorial approach to examine SSH at large concentrations in binary alloys of Fe-Ni, Fe-Co, Pt-Ni, Pt-Co, Ni-Co, Ni-Mo, and Co-Mo. The diffusion couple (DC) method is used to generate concentration ( c) gradients and the nanoindentation (NI) technique to measure the hardness ( H) along these gradients. The obtained H -c profiles are analyzed within the framework of the Labusch model of SSH, and the c^{2/3} dependence of H predicted by the model is found to be generally applicable. The SSH behavior obtained using the combinatorial method is found to be largely consistent with that observed in the literature using conventional and DC-NI methods. This study evaluates SSH in Fe-, Ni-, Co-, and Pt-based binary alloys and confirms the applicability of the DC-NI approach for rapidly screening various solute elements for their SSH ability.

  7. Apparent diffusion coefficient vale of the brain in patients with Gaucher's disease type II and type III

    International Nuclear Information System (INIS)

    Abdel Razek, Ahmed Abdel Khalek; Abd El-Gaber, Nahed; Abdalla, Ahmed; Fathy, Abeer; Azab, Ahmed; Rahman, Ashraf Abdel

    2009-01-01

    The aim of this work is to assess the usefulness of apparent diffusion coefficient (ADC) value of the brain for diagnosis of patients with Gaucher's disease type II and type III. Prospective study was conducted upon 13 patients (nine boys and four girls aged 8 months-14 years: mean 6.1 years) with Gaucher's disease type II and III and for age-matched control group (n = 13). Diffusion-weighted magnetic resonance imaging using a single-shot echo-planar imaging with a diffusion-weighted factor b of 0, 500, and 1,000 s/mm 2 was done for all patients and volunteers. The ADC value was calculated in ten regions of the brain parenchyma and correlated with genotyping. There was significantly lower ADC value of the cortical frontal (P = 0.003), cortical temporal (P = 0.04), frontal subcortical white matter (P = 0.02), corticospinal tract (P = 0.001), cerebellum (P = 0.001), medulla (P = 0.002), and midbrain (P = 0.02) between patients and volunteers. There was significant difference in the ADC value of the frontal and temporal gray matter (P = 0.04 and 0.05, respectively) between patients with heterozygous and homozygous gene mutation. We concluded that ADC value is a new promising quantitative imaging parameter that can be used for the detection of brain abnormalities in patients with Gaucher's disease type II and type III and has a correlation with genotyping. (orig.)

  8. Radiation effects in the rat spinal cord: evaluation with apparent diffusion coefficient versus T2 at serial MR imaging.

    Science.gov (United States)

    Philippens, Marielle E P; Gambarota, Giulio; van der Kogel, Albert J; Heerschap, Arend

    2009-02-01

    To prospectively determine whether apparent diffusion coefficients (ADCs) are more sensitive to radiation-induced changes in the rat spinal cord than T2 relaxation times. The study was approved by the institutional ethical committee on animal welfare. One centimeter of the thoracolumbar spinal cord of six rats was irradiated with 36 Gy. For 3-6 months after irradiation, five 7.0-T magnetic resonance (MR) imaging measurements were performed in each rat until motor impairment developed. Six age-matched rats were examined as controls. Measurements were performed by using diffusion-weighted imaging with five b values and a spin-echo sequence with 20 echoes. ADC and T2 values were calculated, and the spatiotemporal evolution of the radiation-induced lesions was determined semiautomatically. The final MR measurements were compared with the histologic findings. Shortly before the neurologic signs appeared, the first radiation effects manifested as well-circumscribed white matter (WM) lesions with a low longitudinal ADC and normal or high T2. WM lesions with high T2 correlated with confluent necrosis at histologic analysis, whereas WM lesions with normal T2 correlated with focal necrosis and demyelination. In the gray matter (GM), lesions with diffusely high T2 were present and were attributed to edema. T2 changes in the GM preceded T2 and ADC changes in the WM. In the WM, longitudinal ADC was more sensitive for the detection of radiation damage than T2, but in the GM, T2 was more sensitive.

  9. Stefan-Maxwell Relations and Heat Flux with Anisotropic Transport Coefficients for Ionized Gases in a Magnetic Field with Application to the Problem of Ambipolar Diffusion

    Science.gov (United States)

    Kolesnichenko, A. V.; Marov, M. Ya.

    2018-01-01

    The defining relations for the thermodynamic diffusion and heat fluxes in a multicomponent, partially ionized gas mixture in an external electromagnetic field have been obtained by the methods of the kinetic theory. Generalized Stefan-Maxwell relations and algebraic equations for anisotropic transport coefficients (the multicomponent diffusion, thermal diffusion, electric and thermoelectric conductivity coefficients as well as the thermal diffusion ratios) associated with diffusion-thermal processes have been derived. The defining second-order equations are derived by the Chapman-Enskog procedure using Sonine polynomial expansions. The modified Stefan-Maxwell relations are used for the description of ambipolar diffusion in the Earth's ionospheric plasma (in the F region) composed of electrons, ions of many species, and neutral particles in a strong electromagnetic field.

  10. Mutual Diffusion in the Ternary Mixture of Water Plus Methanol Plus Ethanol and Its Binary Subsystems

    Czech Academy of Sciences Publication Activity Database

    Pařez, Stanislav; Guevara-Carrion, G.; Hasse, H.; Vrabec, J.

    2013-01-01

    Roč. 15, č. 11 (2013), s. 3985-4001 ISSN 1463-9076. [EMLG/JMLG Annual Meeting. Eger, 05.09.2012-09.09.2012] Institutional support: RVO:67985858 Keywords : molekular- dynamics simulations * maxwell-stefan diffusitives * activity-coefficient models Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 4.198, year: 2013

  11. An Adaptive Sparse Grid Algorithm for Elliptic PDEs with Lognormal Diffusion Coefficient

    KAUST Repository

    Nobile, Fabio

    2016-03-18

    In this work we build on the classical adaptive sparse grid algorithm (T. Gerstner and M. Griebel, Dimension-adaptive tensor-product quadrature), obtaining an enhanced version capable of using non-nested collocation points, and supporting quadrature and interpolation on unbounded sets. We also consider several profit indicators that are suitable to drive the adaptation process. We then use such algorithm to solve an important test case in Uncertainty Quantification problem, namely the Darcy equation with lognormal permeability random field, and compare the results with those obtained with the quasi-optimal sparse grids based on profit estimates, which we have proposed in our previous works (cf. e.g. Convergence of quasi-optimal sparse grids approximation of Hilbert-valued functions: application to random elliptic PDEs). To treat the case of rough permeability fields, in which a sparse grid approach may not be suitable, we propose to use the adaptive sparse grid quadrature as a control variate in a Monte Carlo simulation. Numerical results show that the adaptive sparse grids have performances similar to those of the quasi-optimal sparse grids and are very effective in the case of smooth permeability fields. Moreover, their use as control variate in a Monte Carlo simulation allows to tackle efficiently also problems with rough coefficients, significantly improving the performances of a standard Monte Carlo scheme.

  12. Determination of diffusion coefficients of carbon dioxide in water between 268 and 473 K in a high-pressure capillary optical cell with in situ Raman spectroscopic measurements

    Science.gov (United States)

    Lu, Wanjun; Guo, Huirong; Chou, I.-Ming; Burruss, R.C.; Li, Lanlan

    2013-01-01

    Accurate values of diffusion coefficients for carbon dioxide in water and brine at reservoir conditions are essential to our understanding of transport behavior of carbon dioxide in subsurface pore space. However, the experimental data are limited to conditions at low temperatures and pressures. In this study, diffusive transfer of carbon dioxide in water at pressures up to 45 MPa and temperatures from 268 to 473 K was observed within an optical capillary cell via time-dependent Raman spectroscopy. Diffusion coefficients were estimated by the least-squares method for the measured variations in carbon dioxide concentration in the cell at various sample positions and time. At the constant pressure of 20 MPa, the measured diffusion coefficients of carbon dioxide in water increase with increasing temperature from 268 to 473 K. The relationship between diffusion coefficient of carbon dioxide in water [D(CO2) in m2/s] and temperature (T in K) was derived with Speedy–Angell power-law approach as: D(CO2)=D0[T/Ts-1]m where D0 = 13.942 × 10−9 m2/s, Ts = 227.0 K, and m = 1.7094. At constant temperature, diffusion coefficients of carbon dioxide in water decrease with pressure increase. However, this pressure effect is rather small (within a few percent).

  13. On weak solutions to a diffuse interface model of a binary mixture of compressible fluids

    Czech Academy of Sciences Publication Activity Database

    Feireisl, Eduard

    2016-01-01

    Roč. 9, č. 1 (2016), s. 173-183 ISSN 1937-1632 R&D Projects: GA ČR GA13-00522S Institutional support: RVO:67985840 Keywords : Euler-Cahn-Hilliard system * weak solution * diffuse interface model Subject RIV: BA - General Mathematics Impact factor: 0.781, year: 2016 http://aimsciences.org/ journals /displayArticlesnew.jsp?paperID=12093

  14. On weak solutions to a diffuse interface model of a binary mixture of compressible fluids

    Czech Academy of Sciences Publication Activity Database

    Feireisl, Eduard

    2016-01-01

    Roč. 9, č. 1 (2016), s. 173-183 ISSN 1937-1632 R&D Projects: GA ČR GA13-00522S Institutional support: RVO:67985840 Keywords : Euler-Cahn-Hilliard system * weak solution * diffuse interface model Subject RIV: BA - General Mathematics Impact factor: 0.781, year: 2016 http://aimsciences.org/journals/displayArticlesnew.jsp?paperID=12093

  15. Comment on "A theoretical framework for quantitatively characterizing sound field diffusion based on scattering coefficient and absorption coefficient of walls" [J. Acoust. Soc. Am. 128, 1140-1148 (2010)] (L).

    Science.gov (United States)

    Omoto, Akira

    2013-01-01

    The relationship between the acoustic scattering characteristics of materials and the degree of diffusion in enclosed acoustic spaces has recently attracted considerable research attention. Hanyu [J. Acoust. Soc. Am. 128(3), 1140-1148 (2010)] introduced a theoretical framework, in which the diffusion time in an enclosure is expressed as a function of a material's average scattering coefficient. In this letter, a modification of this theory is proposed. The decay process of the sound energy through scattering is divided into discrete sub-processes, specifically, a purely scattering process, and alternating scattering and specular reflections. The behavior of each process is examined for different scattering coefficients.

  16. Patterns of accentuated grey-white differentiation on diffusion-weighted imaging or the apparent diffusion coefficient maps in comatose survivors after global brain injury

    International Nuclear Information System (INIS)

    Kim, E.; Sohn, C.-H.; Chang, K.-H.; Chang, H.-W.; Lee, D.H.

    2011-01-01

    Aim: To determine what disease entities show accentuated grey-white differentiation of the cerebral hemisphere on diffusion-weighted images (DWI) or apparent diffusion coefficient (ADC) maps, and whether there is a correlation between the different patterns and the cause of the brain injury. Methods and materials: The DWI and ADC maps of 19 patients with global brain injury were reviewed and evaluated to investigate whether there was a correlation between the different patterns seen on the DWI and ADC maps and the cause of global brain injury. The ADC values were measured for quantitative analysis. Results: There were three different patterns of ADC decrease: a predominant ADC decrease in only the cerebral cortex (n = 8; pattern I); an ADC decrease in both the cerebral cortex and white matter (WM) and a predominant decrease in the WM (n = 9; pattern II); and a predominant ADC decrease in only the WM (n = 3; pattern III). Conclusion: Pattern I is cerebral cortical injury, suggesting cortical laminar necrosis in hypoxic brain injury. Pattern II is cerebral cortical and WM injury, frequently seen in brain death, while pattern 3 is mainly WM injury, especially found in hypoglycaemic brain injury. It is likely that pattern I is decorticate injury and pattern II is decerebrate injury in hypoxic ischaemic encephalopathy.Patterns I and II are found in severe hypoxic brain injury, and pattern II is frequently shown in brain death, whereas pattern III was found in severe hypoglycaemic injury.

  17. Apparent diffusion coefficient values of diffusion-weighted imaging for distinguishing focal pulmonary lesions and characterizing the subtype of lung cancer: a meta-analysis

    International Nuclear Information System (INIS)

    Shen, Guohua; Jia, Zhiyun; Deng, Houfu

    2016-01-01

    The potential performance of apparent diffusion coefficient (ADC) values for distinguishing malignant and benign pulmonary lesions, further characterizing the subtype of lung cancer was assessed. PubMed, EMBASE, Cochrane Library, EBSCO, and three Chinese databases were searched to identify eligible studies on diffusion-weighted imaging (DWI) of focal pulmonary lesions. ADC values of malignant and benign lesions were extracted by lesion type and statistically pooled based on a linear mixed model. Further analysis for subtype of lung cancer was also performed. The methodological quality was assessed using the quality assessment of diagnostic accuracy studies tool. Thirty-four articles involving 2086 patients were included. Malignant pulmonary lesions have significantly lower ADC values than benign lesions [1.21 (95 % CI, 1.19-1.22) mm 2 /s vs. 1.76 (95 % CI, 1.72-1.80) mm 2 /s; P < 0.05]. There is a significant difference between ADC values of small cell lung cancer and non-small cell lung cancer (P < 0.05), while the differences were not significant among histological subtypes of lung cancer. The methodological quality was relatively high, and the data points from Begg's test indicated that there was probably no obvious publication bias. The ADC value is helpful for distinguishing malignant and benign pulmonary lesions and provides a promising method for differentiation of SCLC from NSCLC. (orig.)

  18. Apparent diffusion coefficient values of diffusion-weighted imaging for distinguishing focal pulmonary lesions and characterizing the subtype of lung cancer: a meta-analysis

    Energy Technology Data Exchange (ETDEWEB)

    Shen, Guohua; Jia, Zhiyun; Deng, Houfu [Sichuan University, Department of Nuclear Medicine, West China Hospital, Chengdu, Sichuan (China)

    2016-02-15

    The potential performance of apparent diffusion coefficient (ADC) values for distinguishing malignant and benign pulmonary lesions, further characterizing the subtype of lung cancer was assessed. PubMed, EMBASE, Cochrane Library, EBSCO, and three Chinese databases were searched to identify eligible studies on diffusion-weighted imaging (DWI) of focal pulmonary lesions. ADC values of malignant and benign lesions were extracted by lesion type and statistically pooled based on a linear mixed model. Further analysis for subtype of lung cancer was also performed. The methodological quality was assessed using the quality assessment of diagnostic accuracy studies tool. Thirty-four articles involving 2086 patients were included. Malignant pulmonary lesions have significantly lower ADC values than benign lesions [1.21 (95 % CI, 1.19-1.22) mm{sup 2}/s vs. 1.76 (95 % CI, 1.72-1.80) mm{sup 2}/s; P < 0.05]. There is a significant difference between ADC values of small cell lung cancer and non-small cell lung cancer (P < 0.05), while the differences were not significant among histological subtypes of lung cancer. The methodological quality was relatively high, and the data points from Begg's test indicated that there was probably no obvious publication bias. The ADC value is helpful for distinguishing malignant and benign pulmonary lesions and provides a promising method for differentiation of SCLC from NSCLC. (orig.)

  19. Reversal of apparent diffusion coefficient (ADC) following transient focal cerebral ischemia in cats

    International Nuclear Information System (INIS)

    Kim, Hyun Sook; Yoon, Yong Kyu; Kim, Dong Ik; Lee, Seung Koo

    2002-01-01

    To determine the minimal threshold ADC ratio suggesting reversible ischemia in a temporary model of MCAO. Seven Korean cats weighing 3-3.5 kg were used as a temporary model of MCAO. The MCA was occluded for 1 hour, and diffusion-weighted images (DWI), and ADC and regional cerebral blood volume (rCBV) maps, were obtained at 1, 3, 6 and 24 hours after reperfusion using a 1.5T MR unit. The Cats were sacrificed 24 hours after imaging. Triphenyl tetrazolium chloride (TTC) staining of brain slices was performed, and DWI images and TTC-stained brain slices were compared with the naked eye. Reversible ischemia was defined as the area of high signal intensity at 1-hour DWI that normalized at follow-up DWI and in which TTC staining was normal. Using the ADC image obtained at 1 hour after reperfusion, 60 ADC ratios were obtained in the periphery of the infarct and reversible ischemia. Tissue survival showing normal TTC staining was used for final determination. The sensitivity and specificity of each ADC ratio was obtained and an ROC curve was plotted. Five of seven cats showed the reversible ischemia. An area of high signal intensity was seen on DWI images obtained 1 hours after reperfusion, and this improved at follow-up imaging. The distribution of the ADC ratio in the periphery of the infarct core was 0.71-0.81, and in the periphery of reversible ischemia it was 0.79-0.93. The ADC ratio of 0.80 obtained 1 hr after reperfusion predicted the survival of the ischemic tissure with 93% sensitivity and 90% specificity. The ADC ratio of the reversible ischemia was 0.82 ±0.03 at 1 hour after reperfusion, and this was higher than that of the infarct, which was 0.74±0.03. The minimal threshold ADC ratio suggesting reversible ischemia in this temporary model of MCAO was 0.80

  20. A CUMULATIVE MIGRATION METHOD FOR COMPUTING RIGOROUS TRANSPORT CROSS SECTIONS AND DIFFUSION COEFFICIENTS FOR LWR LATTICES WITH MONTE CARLO

    Energy Technology Data Exchange (ETDEWEB)

    Zhaoyuan Liu; Kord Smith; Benoit Forget; Javier Ortensi

    2016-05-01

    A new method for computing homogenized assembly neutron transport cross sections and dif- fusion coefficients that is both rigorous and computationally efficient is proposed in this paper. In the limit of a homogeneous hydrogen slab, the new method is equivalent to the long-used, and only-recently-published CASMO transport method. The rigorous method is used to demonstrate the sources of inaccuracy in the commonly applied “out-scatter” transport correction. It is also demonstrated that the newly developed method is directly applicable to lattice calculations per- formed by Monte Carlo and is capable of computing rigorous homogenized transport cross sections for arbitrarily heterogeneous lattices. Comparisons of several common transport cross section ap- proximations are presented for a simple problem of infinite medium hydrogen. The new method has also been applied in computing 2-group diffusion data for an actual PWR lattice from BEAVRS benchmark.

  1. MEASUREMENT of Protein 53 Diffusion Coefficient in Live HeLa Cells Using Raster Image Correlation Spectroscopy (RICS).

    Science.gov (United States)

    Hong, Sungmin; Wang, Ying-Nai; Yamaguchi, Hirohito; Sreenivasappa, Harinibytaraya; Chou, Chao-Kai; Tsou, Pei-Hsiang; Hung, Mien-Chie; Kameoka, Jun

    2010-10-01

    We have applied Raster Image Correlation Spectroscopy (RICS) technique to characterize the dynamics of protein 53 (p53) in living cells before and after the treatment with DNA damaging agents. HeLa cells expressing Green Fluorescent Protein (GFP) tagged p53 were incubated with and without DNA damaging agents, cisplatin or eptoposide, which are widely used as chemotherapeutic drugs. Then, the diffusion coefficient of GFP-p53 was determined by RICS and it was significantly reduced after the drug treatment while that of the one without drug treatment was not. It is suggested that the drugs induced the interaction of p53 with either other proteins or DNA. Together, our results demonstrated that RICS is able to detect the protein dynamics which may be associated with protein-protein or protein-DNA interactions in living cells and it may be useful for the drug screening.

  2. Communicating Hydrocephalus Associated with Small- to Medium-Sized Vestibular Schwannomas: Clinical Significance of the Tumor Apparent Diffusion Coefficient Map.

    Science.gov (United States)

    Taniguchi, Masaaki; Nakai, Tomoaki; Kohta, Masaaki; Kimura, Hidehito; Kohmura, Eiji

    2016-10-01

    The etiology of hydrocephalus associated with the small- to medium-sized vestibular schwannomas is still controversial. We investigated tumor-specific factors related to the association of hydrocephalus with small- to medium-sized vestibular schwannomas. Among the 77 patients with vestibular schwannoma smaller than 30 mm, 9 patients demonstrated associated communicating hydrocephalus. Patient medical records, radiologic data, and histopathologic specimens were reviewed retrospectively. The age of the patients, and size, mean apparent diffusion coefficient (ADC) value, and histologic features of the tumors were compared with those of patients without hydrocephalus. The symptoms related to hydrocephalus improved in all patients after tumor removal. Both the mean size and ADC values exhibited a statistically significant difference between the tumors with and without hydrocephalus (P hydrocephalus. The increased tumor ADC value was considered to be the result of degenerative change and suggested the involvement of protein sloughing in the etiology of the associated hydrocephalus. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. 17beta-estradiol matrixpatch removal and reapplication in postmenopausal women: theoretical predictions with an oscillating diffusion coefficient model.

    Science.gov (United States)

    Rohr, Uwe D; Saeger-Lorenz, Katrin

    2002-03-01

    temperature was detected as 35.6 degrees C with an amplitude of +/- 0.5 degrees C with an acrophase at 17.51 o'clock (95% CI: 14.30-21.00) (p = 0.05). The temperature period was 24 h for all measurements and the maximum temperature was observed at about 16.30 h, and a minimum at about 5.00 h. A linear dependency was detected in in vitro experiments between the log of E(2) permeability and the temperature for stripped skin, epidermis/dermis layer, as well as for the matrix. Modeling of E(2) plasma profiles with oscillating diffusion coefficients (ODM1) with a sine wave function results in this equation: D(1) = D(0x) + Da(x).sin(k.t). D(0x) is the diffusion coefficient determined at 35.6 degrees C, k is 1/24 h, D(a) is the diffusion coefficient of the temperature amplitude, h is hour, and x stands for the respective diffusion layer. It was shown that the experimental E(2) plasma profile variations are more pronounced than can simply be explained by skin temperature variations alone (ODM1 model). A simplex fit with an oscillating diffusion coefficient in the form of a sine wave function for the stratum corneum (ODM2 model) resulted in a temperature amplitude of 1.1 degrees C, about twice as high as was determined in the in vivo measurements (ODM2 model). Therefore, other circadian parameterlike blood flow might superimpose the temperature profile. The improvement in data analysis by incorporating oscillating diffusion coefficients (ODM1 and 2) over CPM was judged from a comparison of experimental data with the calculated plasma profiles with the AIC, Akaikes model selection criterion, which allows ranking between models because it is independent of the scaling of the data points. ODM1 and ODM2 improved the data analysis over CPM by allowing better calculation of experimental C(max), t(max), the time to reach to C(max), and the fluctuation, f. No difference between CPM, ODM1, or ODM2 was found for the bioavailability parameter C(average) and AUC(0-96h). (c) 2002 Wiley-Liss, Inc

  4. Diffusion coefficient, porosity measurement, dynamic and equilibrium swelling studies of Acrylic acid/Polyvinyl alcohol (AA/PVA hydrogels

    Directory of Open Access Journals (Sweden)

    Nazar Mohammad Ranjha

    2015-06-01

    Full Text Available Objective of the present work was to synthesize hydrogels of acrylic acid/polyvinyl alcohol (AA/PVA by free radical polymerization by using glutaradehyde (GA as crosslinkers. The hydrogels were evaluated for swelling, diffusion coefficient and network parameters like the average molecular weight between crosslink’s, polymer volume fraction in swollen state, number of repeating units between crosslinks and crosslinking density by using Flory-Huggins theory. It was found that the degree of swelling of AA/PVA hydrogels increases greatly within the pH range 5-7. The gel fraction and porosity increased by increasing the concentration of AA or PVA. Increase in degree of crosslinking, decreased the porosity and inverse was observed in gel fraction. Selected samples were loaded with metoprolol tartrate. Drug release was studied in USP hydrochloric acid solution of pH 1.2 and phosphate buffer solutions of pH 5.5 and 7.5. Various kinetics models like zero order, first order, Higuchi and Peppas model were used for in vitro kinetic studies. The results showed that the drug release followed concentration dependent effect (First order kinetics with non-Fickian diffusion. FTIR and SEM used to study the structure, crystallinity, compatibility, thermal stability and morphology of prepared and drug loaded hydrogels respectively.

  5. Can measurement of apparent diffusion coefficient before treatment predict the response to uterine artery embolization for adenomyosis?

    Energy Technology Data Exchange (ETDEWEB)

    Park, Yaewon; Kim, Man Deuk; Jung, Dae Chul; Lee, Shin Jae; Kim, Gyoungmin; Park, Sung Il; Won, Jong Yun; Lee, Do Yun [Yonsei University College of Medicine, Department of Radiology, Severance Hospital, Seoul (Korea, Republic of)

    2015-05-01

    To determine the usefulness of the apparent diffusion coefficient (ADC) in predicting response to uterine artery embolization (UAE) for symptomatic adenomyosis. A prospective study was performed on 25 patients who underwent diffusion-weighted (DW) magnetic resonance imaging (MRI) before UAE between June 2011 and December 2012. All patients underwent 3-month follow-up MRI after UAE using non-spherical polyvinyl alcohol (PVA) particles ranging from 150 to 500 μm. Quantitative measurement of the ADC was performed for each adenomyosis. Complete response and incomplete response were defined as ≥90 % or <90 %, respectively, of the non-perfusion area with adenomyosis at the follow-up MRI. The ADC values were compared between patients who achieved complete or incomplete response which was assessed according to the MRI findings after UAE. Nineteen patients showed complete response, and six showed incomplete response. The ADC value ranged from 0.842 to 1.346 x 10{sup -3} mm{sup 2}/s (mean 1.075 ± 0.117). The mean ADC was 1.043 ± 0.237 in the complete response group and 1.176 ± 0.429 in the incomplete response group (0.012). Using a threshold of <1.147 x 10{sup -3} mm{sup 2}/s, the sensitivity and specificity of the ADC to predict success after UAE were 83.3 % and 84.2 %. The ADC of adenomyosis may potentially predict a successful response to UAE for adenomyosis. (orig.)

  6. Normal regional fractional anisotropy and apparent diffusion coefficient of the brain measured on a 3 T MR scanner

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Christabel E.C.; Thomasson, David; Baker, Eva H. [National Institutes of Health, Department of Diagnostic Radiology, Clinical Center, Bethesda, MD (United States); Danielian, Laura E. [National Institutes of Health, National Institute of Neurological Disease and Stroke, Bethesda, MD (United States)

    2009-01-15

    We aim to establish norms of fractional anisotropy (FA) and apparent diffusion coefficient (ADC) in 20 different regions of the brain in healthy human volunteers. Thirty-one individuals were examined for ADC and FA in 20 regions of the brain using a single-shot, spin echo, echo planar diffusion tensor imaging sequence with 32 directions at 3 T. FA and ADC maps were computed using the Philips PRIDE tool, and regions of interest were drawn at 20 different locations in the brain. Relationships of FA and ADC with age and gender were explored. We found a negative correlation between age and FA in the inferior fronto-occipital fasciculus and forceps minor. There were no gender differences. The cerebral peduncle, the middle cerebellum, and cingulum had the highest variation in FA, while fornix, optic radiation, and optic tract had the highest variation in ADC. We provide a table of normative FA and ADC measurements in 20 brain regions of potential clinical relevance to the diagnosis and monitoring of specific neurological diseases. (orig.)

  7. Repeatability of apparent diffusion coefficient and intravoxel incoherent motion parameters at 3.0 Tesla in orbital lesions

    Energy Technology Data Exchange (ETDEWEB)

    Lecler, Augustin [Fondation Ophtalmologique Adolphe de Rothschild, Department of Radiology, Paris (France); Cardiovascular Research Centre - PARCC, Universite Paris Descartes Sorbonne Paris Cite, INSERM UMR-S970, Paris (France); Savatovsky, Julien; Sadik, Jean-Claude; Charbonneau, Frederique; Berges, Olivier [Fondation Ophtalmologique Adolphe de Rothschild, Department of Radiology, Paris (France); Balvay, Daniel [Cardiovascular Research Centre - PARCC, Universite Paris Descartes Sorbonne Paris Cite, INSERM UMR-S970, Paris (France); Zmuda, Mathieu; Galatoire, Olivier [Fondation Ophtalmologique Adolphe de Rothschild, Department of Orbitopalpebral Surgery, Paris (France); Picard, Herve [Fondation Ophtalmologique Adolphe de Rothschild, Clinical Research Unit, Paris (France); Fournier, Laure [Cardiovascular Research Centre - PARCC, Universite Paris Descartes Sorbonne Paris Cite, INSERM UMR-S970, Paris (France); Universite Paris Descartes Sorbonne Paris Cite, Assistance Publique-Hopitaux de Paris, Hopital Europeen Georges Pompidou, Radiology Department, Paris (France)

    2017-12-15

    To evaluate repeatability of intravoxel incoherent motion (IVIM) diffusion-weighted imaging (DWI) parameters in the orbit. From December 2015 to March 2016, 22 patients were scanned twice using an IVIM sequence with 15b values (0-2,000 s/mm{sup 2}) at 3.0T. Two readers independently delineated regions of interest in an orbital mass and in different intra-orbital and extra-orbital structures. Short-term test-retest repeatability and inter-observer agreement were assessed using the intra-class correlation coefficient (ICC), the coefficient of variation (CV) and Bland-Altman limits of agreements (BA-LA). Test-retest repeatability of IVIM parameters in the orbital mass was satisfactory for ADC and D (mean CV 12% and 14%, ICC 95% and 93%), poor for f and D*(means CV 43% and 110%, ICC 90% and 65%). Inter-observer repeatability agreement was almost perfect in the orbital mass for all the IVIM parameters (ICC = 95%, 93%, 94% and 90% for ADC, D, f and D*, respectively). IVIM appeared to be a robust tool to measure D in orbital lesions with good repeatability, but this approach showed a poor repeatability of f and D*. (orig.)

  8. Initial Experience of 3-Tesla Apparent Diffusion Coefficient Values in Characterizing Squamous Cell Carcinomas of the Head and Neck

    Energy Technology Data Exchange (ETDEWEB)

    Srinivasan, A.; Dvorak, R.; Rohrer, S.; Mukherji, S.K. (Dept. of Radiology, Division of Neuroradiology, Univ. of Michigan Health System, Ann Arbor, MI (United States))

    2008-11-15

    Background: With the increased clinical use of 3-Tesla (3T) magnets, it becomes important to identify the potential applications of advanced magnetic resonance (MR) imaging techniques such as diffusion-weighted imaging in head and neck pathologies. Purpose: To establish the 3T apparent diffusion coefficient (ADC) values for normal neck structures, and to examine the utility of ADC values in distinguishing head and neck squamous cell carcinomas (HNSCC) from normal neck anatomy. Material and Methods: 3T diffusion-weighted imaging was performed on 10 normal volunteers and 10 patients with known HNSCC. In the volunteers, mean ADC was calculated in the parotid gland, submandibular gland, base of the tongue, pterygoid muscle, masseter muscle, paraspinal muscles, true vocal cord, thyroid gland, thyroid cartilage, cricoid cartilage, and lymph nodes. The mean tumor ADC value was calculated from the 10 patients with HNSCC and compared with the normal ADC values from various neck structures. Results: The mean ADC value measured in the HNSCC was 1.101 (+-0.214)x10-3mm2/s. This was significantly lower than ADC values of paraspinal muscles, pterygoid muscle, masseter muscle, thyroid gland, and base of the tongue (P=0.0006, 0.0002, 0.0001, 0.001, and 0.002, respectively). The tumor ADC values were not significantly different from ADC values of parotid and submandibular glands (P=0.057 and 0.14, respectively). Conclusion: 3T ADC values show potential for distinguishing HNSCC from normal extracranial head and neck structures

  9. Bounce-averaged advection and diffusion coefficients for monochromatic electromagnetic ion cyclotron wave: Comparison between test-particle and quasi-linear models

    Science.gov (United States)

    Su, Z.; Zhu, H.; Xiao, F.; Zheng, H.; Shen, C.; Wang, Y.; Wang, S.

    2012-12-01

    The electromagnetic ion cyclotron (EMIC) wave has been long suggested to be responsible for the rapid loss of radiation belt relativistic electrons. The test-particle simulations are performed to calculate the bounce-averaged pitch-angle advection and diffusion coefficients for parallel-propagating monochromatic EMIC waves. The comparison between test-particle (TP) and quasi-linear (QL) transport coefficients is further made to quantify the influence of nonlinear processes. For typical EMIC waves, four nonlinear physical processes, i.e., the boundary reflection effect, finite perturbation effect, phase bunching and phase trapping, are found to occur sequentially from small to large equatorial pitch angles. The pitch-angle averaged finite perturbation effect yields slight differences between the transport coefficients of TP and QL models. The boundary reflection effect and phase bunching produce an average reduction of >80% in the diffusion coefficients but a small change in the corresponding average advection coefficients, tending to lower the loss rate predicted by QL theory. In contrast, the phase trapping causes continuous negative advection toward the loss cone and a minor change in the corresponding diffusion coefficients, tending to increase the loss rate predicted by QL theory. For small amplitude EMIC waves, the transport coefficients grow linearly with the square of wave amplitude. As the amplitude increases, the boundary reflection effect, phase bunching and phase trapping start to occur. Consequently, the TP advection coefficients deviate from the linear growth with the square of wave amplitude, and the TP diffusion coefficients become saturated with the amplitude approaching 1nT or above. The current results suggest that these nonlinear processes can cause significant deviation of transport coefficients from the prediction of QL theory, which should be taken into account in the future simulations of radiation belt dynamics driven by the EMIC waves.

  10. Molecular dynamics simulation to assess the effect of temperature on diffusion coefficients of different ions and water molecules in C-S-H

    Science.gov (United States)

    Zehtab, B.; Tarighat, A.

    2017-10-01

    Diffusion is a particle transportation process beginning from one point of a system to another through random molecular motion. This process depends on various parameters like temperature, concentration gradient, and particle size. The objective of this article is to assess the variation of diffusion coefficients of water molecules, chloride and sodium ions against different temperatures in calcium silicate hydrates (C-S-H) through molecular dynamics simulation. A uniform sodium chloride solution is modeled between cement hydrate layers with no concentration gradient. In such a solution, temperature could affect diffusion process in a significant manner. The two most important crystalline mineral analogues of C-S-H, tobermorite and jennite, are applied in this simulation. Diffusion coefficients of different ions and water molecules are found in different temperatures. It is revealed that diffusion coefficient is higher at high temperatures. Activation energies of chloride and sodium ions transport in cement hydrates are calculated through Arrhenius law. Output values of diffusion coefficients and activation energies are compared to previous experimental and simulation results in the related literature. A multi-scale analysis is run to estimate the penetration depth of Cl- ions in cement paste through Fick's second law.

  11. Diffusion-weighted MR imaging of the normal pancreas: reproducibility and variations of apparent diffusion coefficient measurement at 1.5- and 3.0-Tesla.

    Science.gov (United States)

    Barral, M; Soyer, P; Ben Hassen, W; Gayat, E; Aout, M; Chiaradia, M; Rahmouni, A; Luciani, A

    2013-04-01

    To evaluate reproducibility and variations in apparent diffusion coefficient (ADC) measurement in normal pancreatic parenchyma at 1.5- and 3.0-Tesla and determine if differences may exist between the four pancreatic segments. Diffusion-weighted MR imaging of the pancreas was performed at 1.5-Tesla in 20 patients and at 3.0-Tesla in other 20 patients strictly matched for gender and age using the same b values (0, 400 and 800s/mm(2)). Two independent observers placed regions of interest within the four pancreatic segments to measure ADC at both fields. Intra- and inter-observer agreement in ADC measurement was assessed using Bland-Altman analysis and comparison between ADC values obtained at both fields using non-parametrical tests. There were no significant differences in ADC between repeated measurements and between ADC obtained at 1.5-Tesla and those at 3.0-Tesla. The 95% limits of intra-observer agreement between ADC were 2.3%-22.7% at 1.5-Tesla and 1%-24.2% at 3.0-Tesla and those for inter-observer agreement between 1.9%-14% at 1.5-Tesla and 8%-25% at 3.0-Tesla. ADC values were similar in all pancreatic segments at 3.0-T whereas the tail had lower ADC at 1.5-Tesla. ADC measurement conveys high degrees of intra- and inter-observer reproducibility. ADC have homogeneous distribution among the four pancreatic segments at 3.0-Tesla. Copyright © 2012 Éditions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.

  12. Diffusion weighted imaging of liver lesions suspect for metastases: Apparent diffusion coefficient (ADC) values and lesion contrast are independent from Gd-EOB-DTPA administration

    Energy Technology Data Exchange (ETDEWEB)

    Benndorf, Matthias, E-mail: matthias.benndorf@uni-jena.de [Institute of Diagnostic and Interventional Radiology, University Hospital Jena, Erlanger Allee 101, 07747 Jena (Germany); Schelhorn, Juliane, E-mail: j.schelhorn@klinikum-weimar.de [Department of Radiology and Nuclear Medicine, Sophien- und Hufeland-Klinikum Weimar, Henry-van-de-Velde-Strasse 2, 99425 Weimar (Germany); Dietzel, Matthias, E-mail: matthias.dietzel@med.uni-jena.de [Institute of Diagnostic and Interventional Radiology, University Hospital Jena, Erlanger Allee 101, 07747 Jena (Germany); Kaiser, Werner A., E-mail: werner.kaiser@med.uni-jena.de [Institute of Diagnostic and Interventional Radiology, University Hospital Jena, Erlanger Allee 101, 07747 Jena (Germany); Baltzer, Pascal A.T., E-mail: pascal.baltzer@med.uni-jena.de [Institute of Diagnostic and Interventional Radiology, University Hospital Jena, Erlanger Allee 101, 07747 Jena (Germany)

    2012-08-15

    Purpose: Gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid (Gd-EOB-DTPA) enhanced liver MRI is widely used for detection and differentiation of focal liver lesions. Diffusion weighted imaging (DWI) including apparent diffusion coefficient (ADC) measurements is increasingly utilised as a fast and, with limitations, quantitative method for liver lesion detection and characterisation. Herein we investigate whether the administration of Gd-EOB-DTPA affects DWI. Materials and methods: 31 consecutive patients referred to standardised liver MRI (1.5 T, Gd-EOB-DTPA, 0.025 mmol/kg) were retrospectively reviewed. All underwent a breathhold DWI sequence before and after contrast agent administration (EPI-DWI, TR/TE (effective): 2100/62 ms, b-values: 0 and 800 s/mm{sup 2}). Patients with previously treated liver lesions were excluded. Signal intensity of lesion, parenchyma and noise on DWI images as well as the ADC value were measured after identification by two observers in consensus using manually placed regions of interest. The reference standard was imaging follow-up determined separately by two radiologists. Data analysis included signal-to-noise (SNR) ratio and contrast-to-noise ratio (CNR) calculations, comparisons were drawn by employing multiple Bonferroni corrected Wilcoxon signed-rank tests. Results: 50 malignant and 39 benign lesions were identified. Neither SNR, CNR nor ADC values showed significant differences between pre- and postcontrast DWI. Both pre- and postcontrast ADC values differed significantly between benign and malignant lesions (P < 0.001). Conclusion: We did not identify a significant influence of Gd-EOB-DTPA on DWI of liver lesions. This allows for individual tailoring of imaging protocols according to clinical needs.

  13. Prognostic value of diffusion-weighted imaging summation scores or apparent diffusion coefficient maps in newborns with hypoxic-ischemic encephalopathy

    Energy Technology Data Exchange (ETDEWEB)

    Cavalleri, Francesca; Todeschini, Alessandra [Azienda Unita Sanitaria Locale di Modena, Neuroradiology Unit, Department of Neuroscience, Nuovo Ospedale Civile S. Agostino Estense di Modena, Modena (Italy); Lugli, Licia; Pugliese, Marisa; Della Casa, Elisa; Gallo, Claudio; Frassoldati, Rossella; Ferrari, Fabrizio [Modena University Hospital, Institute of Pediatrics and Neonatal Medicine and NICU, Modena (Italy); D' Amico, Roberto [University of Modena and Reggio Emilia, Department of Clinical and Diagnostic Medicine and Public Health, Modena (Italy)

    2014-09-15

    The diagnostic and prognostic assessment of newborn infants with hypoxic-ischemic encephalopathy (HIE) comprises, among other tools, diffusion-weighted imaging (DWI) and apparent diffusion coefficient (ADC) maps. To compare the ability of DWI and ADC maps in newborns with HIE to predict the neurodevelopmental outcome at 2 years of age. Thirty-four term newborns with HIE admitted to the Neonatal Intensive Care Unit of Modena University Hospital from 2004 to 2008 were consecutively enrolled in the study. All newborns received EEG, conventional MRI and DWI within the first week of life. DWI was analyzed by means of summation (S) score and regional ADC measurements. Neurodevelopmental outcome was assessed with a standard 1-4 scale and the Griffiths Mental Developmental Scales - Revised (GMDS-R). When the outcome was evaluated with a standard 1-4 scale, the DWI S scores showed very high area under the curve (AUC) (0.89) whereas regional ADC measurements in specific subregions had relatively modest predictive value. The lentiform nucleus was the region with the highest AUC (0.78). When GMDS-R were considered, DWI S scores were good to excellent predictors for some GMDS-R subscales. The predictive value of ADC measurements was both region- and subscale-specific. In particular, ADC measurements in some regions (basal ganglia, white matter or rolandic cortex) were excellent predictors for specific GMDS-R with AUCs up to 0.93. DWI S scores showed the highest prognostic value for the neurological outcome at 2 years of age. Regional ADC measurements in specific subregions proved to be highly prognostic for specific neurodevelopmental outcomes. (orig.)

  14. Diffusion-Tensor Imaging of Thigh Muscles in Duchenne Muscular Dystrophy: Correlation of Apparent Diffusion Coefficient and Fractional Anisotropy Values With Fatty Infiltration.

    Science.gov (United States)

    Li, Gui Dian; Liang, Ying Yin; Xu, Ping; Ling, Jian; Chen, Ying Ming

    2016-04-01

    The purpose of this study is to investigate the correlation of apparent diffusion coefficient (ADC) and fractional anisotropy (FA) values with fatty infiltration in the thigh muscles of patients with Duchenne muscular dystrophy (DMD) using diffusion-tensor imaging (DTI). Twenty-one boys with DMD were recruited. The grade of fatty infiltration and the ADC and FA values of four thigh muscles (rectus femoris, semitendinosus, sartorius, and gracilis) were measured, and the FA and ADC values were compared with the grade of fatty infiltration. Twenty age-matched healthy boys were enrolled as the control group. The differences in the ADC and FA values of the thigh muscles between patients with DMD and the control group were compared. The patients with DMD showed lower FA values and higher ADC values in all measured muscles when compared with the control group. The FA and ADC values were correlated with the grade of fatty infiltration. For the rectus femoris muscle, r = -0.753 and p = 0.007 for FA, and r = 0.685 and p = 0.001 for ADC. For the semitendinosus muscle, r = -0.621 and p = 0.041 for FA, and r = 0.705 and p = 0.021 for ADC. For the sartorius muscle, r = -0.662 and p = 0.027 for FA, and r = 0.701 and p = 0.017 for ADC. For the gracilis muscle, r = -0.618 and p = 0.043 for FA, and r = 0.695 and p = 0.022 for ADC. Damage to the thigh muscles in patients with DMD can be detected by ADC and FA values using DTI. DTI can be used to assess the severity of the disease.

  15. [Quantitative analysis of diffusion-weighted magnetic resonance images during chemoradiation therapy for cancer of the cervix uteri: Prognostic role of pretreatment diffusion coefficient values].

    Science.gov (United States)

    Kharuzhyk, S A

    2015-01-01

    to carry out a quantitative analysis of diffusion-weighted magnetic resonance images (DWI) in cancer of the cervix uteri (CCU) and to estimate the possibility of using pretreatment measured diffusion coefficient (MDC) to predict chemoradiation therapy (CRT). The investigation prospectively enrolled 46 women with morphologically verified Stages IB-IVB CCU. All the women underwent diffusion-weighted magnetic resonance imaging of pelvic organs before and after treatment. A semiautomatic method was used to determine tumor signal intensity (SI) on DWI at b 1000 s/mm2 (SI b1000) and tumor MDC. The reproducibility of MDC measurements was assessed in 16 randomly selected women. The investigators compared the pretreatment quantitative DWI measures in complete and incomplete regression (CR and IR) groups and the presence and absence of tumor progression during a follow-up. An association of MDC with progression-free and overall survivals (PFS and OS) was determined in the patients. A semiautomatic tumor segmentation framework could determine the pretreatment quantitative DMI measures with minimal time spent and high reproducibility. The mean tumor MDC was 0.82 +/- 0.14 x 10(-3) mm2/s. CR and IR were established in 28 and 18 women, respectively. The MDC < or = 0.83 x 10(-3) mm2/s predicted CR with a sensitivity of 64.3% and a specificity of 77.8% (p=0.007). The median follow-up was 47 months (range, 3-82 months). With the MDC < or = 0.86 x 10(-3) mm2/s, 5-year PFS was 74.1% versus 42.1% with a higher MDC (p=0.023) and 5-year OS was 70.4 and 40.6%, respectively (p=0.021). The survival difference was insignificant in relation to the degree of tumor regression. The pretreatment IS at b1000 was of no prognostic value. The pretreatment tumor MDC may serve as a biomarker for predicting the efficiency of CRT for CCU.

  16. Nuclear Overhauser Enhancement Imaging of Glioblastoma at 7 Tesla: Region Specific Correlation with Apparent Diffusion Coefficient and Histology

    Science.gov (United States)

    Windschuh, Johannes; Meissner, Jan-Eric; Zaiss, Moritz; Eidel, Oliver; Kickingereder, Philipp; Nowosielski, Martha; Wiestler, Benedikt; Sahm, Felix; Floca, Ralf Omar; Neumann, Jan-Oliver; Wick, Wolfgang; Heiland, Sabine; Bendszus, Martin; Schlemmer, Heinz-Peter; Ladd, Mark Edward; Bachert, Peter; Radbruch, Alexander

    2015-01-01

    Objective To explore the correlation between Nuclear Overhauser Enhancement (NOE)-mediated signals and tumor cellularity in glioblastoma utilizing the apparent diffusion coefficient (ADC) and cell density from histologic specimens. NOE is one type of chemical exchange saturation transfer (CEST) that originates from mobile macromolecules such as proteins and might be associated with tumor cellularity via altered protein synthesis in proliferating cells. Patients and Methods For 15 patients with newly diagnosed glioblastoma, NOE-mediated CEST-contrast was acquired at 7 Tesla (asymmetric magnetization transfer ratio (MTRasym) at 3.3ppm, B1 = 0.7 μT). Contrast enhanced T1 (CE-T1), T2 and diffusion-weighted MRI (DWI) were acquired at 3 Tesla and coregistered. The T2 edema and the CE-T1 tumor were segmented. ADC and MTRasym values within both regions of interest were correlated voxelwise yielding the correlation coefficient rSpearman (rSp). In three patients who underwent stereotactic biopsy, cell density of 12 specimens per patient was correlated with corresponding MTRasym and ADC values of the biopsy site. Results Eight of 15 patients showed a weak or moderate positive correlation of MTRasym and ADC within the T2 edema (0.16≤rSp≤0.53, p0.05, n = 4) or yielded rSp≈0 (p0.05, n = 6). The biopsy-analysis within CE-T1 tumor revealed a strong positive correlation between tumor cellularity and MTRasym values in two of the three patients (rSppatient3 = 0.69 and rSppatient15 = 0.87, p<0.05), while the correlation of ADC and cellularity was heterogeneous (rSppatient3 = 0.545 (p = 0.067), rSppatient4 = -0.021 (p = 0.948), rSppatient15 = -0.755 (p = 0.005)). Discussion NOE-imaging is a new contrast promising insight into pathophysiologic processes in glioblastoma regarding cell density and protein content, setting itself apart from DWI. Future studies might be based on the assumption that NOE-mediated CEST visualizes cellularity more accurately than ADC, especially in the

  17. Devising a measuring system for the determination of diffusion coefficients in biofilm; Entwicklung eines Messsystems zur Bestimmung von Diffusionskoeffizienten im Biofilm

    Energy Technology Data Exchange (ETDEWEB)

    Berndt, K. [Fachhochschule Magdeburg (Germany). Fachbereich Chemie; Horn, H. [Fachhochschule Magdeburg (Germany). Hydro- und Abfallchemie

    1999-07-01

    The diffusion coefficient of a substrate in a biofilm is an important parameter for simulating mass turnover and transport in biofilm systems. The described method permits determining the diffusion coefficients in biofilms grown under defined substrate and hydrodynamic conditions in a laboratory reactor. (orig.) [German] Der Diffusionskoeffizient des Substrats in Biofilmen ist ein wichtiger Parameter fuer die Simulation von Stoffwechsel und -transport in Biofilmsystemen. Die dargestellte Methode erlaubt die Bestimmung des Diffusionskoeffizienten in Biofilmen, die unter definierten Substrat- und hydrodynamischen Bedingungen in einem Laborreaktor gewachsen sind. (orig.)

  18. Apparent diffusion coefficient as it relates to histopathology findings in post-chemotherapy nephroblastoma: a feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Littooij, Annemieke S. [University Medical Centre Utrecht/Wilhelmina Children' s Hospital, Department of Radiology and Nuclear Medicine, Utrecht (Netherlands); Nikkels, Peter G. [University Medical Centre Utrecht, Department of Pathology, Utrecht (Netherlands); Hulsbergen-van de Kaa, Christina A. [Radboud University Medical Centre, Department of Pathology, Nijmegen (Netherlands); Ven, Cees P. van de [Princess Maxima Centre for Paediatric Oncology, Department of Paediatric Surgery, Utrecht (Netherlands); Heuvel-Eibrink, Marry M. van den [Princess Maxima Centre for Paediatric Oncology, Department of Paediatric Oncology, Utrecht (Netherlands); Olsen, Oeystein E. [Great Ormond Street Hospital for Children, Department of Radiology, London (United Kingdom)

    2017-11-15

    Nephroblastomas represent a group of heterogeneous tumours with variable proportions of distinct histopathological components. The purpose of this study was to investigate whether direct comparison of apparent diffusion coefficient (ADC) measurements with post-resection histopathology subtypes is feasible and whether ADC metrics are related to histopathological components. Twenty-three children were eligible for inclusion in this retrospective study. All children had MRI including diffusion-weighted imaging (DWI) after preoperative chemotherapy, just before tumour resection. A pathologist and radiologist identified corresponding slices at MRI and postoperative specimens using tumour morphology, the upper/lower calyx and hilar vessels as reference points. An experienced reader performed ADC measurements, excluding non-enhancing areas. A pathologist reviewed the corresponding postoperative slides according to the international standard guidelines. We tested potential associations with the Spearman rank test. Side-by-side comparison of MRI-DWI with corresponding histopathology slides was feasible in 15 transverse slices in 9 lesions in 8 patients. Most exclusions were related to extensive areas of necrosis/haemorrhage. In one lesion correlation was not possible because of the different orientation of sectioning of the specimen and MRI slices. The 25% ADC showed a strong relationship with percentage of blastema (Spearman rho=-0.71, P=0.003), whereas median ADC was strongly related to the percentage stroma (Spearman rho=0.74, P=0.002) at histopathology. Side-by-side comparison of MRI-DWI and histopathology is feasible in the majority of patients who do not have massive necrosis and hemorrhage. Blastemal and stromal components have a strong linear relationship with ADC markers. (orig.)

  19. Apparent diffusion coefficient values of necrotic and solid portion of lymph nodes: Differential diagnostic value in cervical lymphadenopathy

    International Nuclear Information System (INIS)

    Zhang, Y.; Chen, J.; Shen, J.; Zhong, J.; Ye, R.; Liang, B.

    2013-01-01

    Aim: To evaluate whether the analysis of the apparent diffusion coefficient (ADC) values of the necrotic and solid portions of lymph nodes aids differentiation between the causes of cervical lymphadenopathy. Materials and methods: Thirty-six patients with cervical lymph node metastasis from head and neck squamous cell carcinomas (SCC), 19 patients with lymphoma, and 23 patients with tuberculous lymphadenitis underwent conventional magnetic resonance imaging (MRI) and diffusion-weighted imaging (DWI). The ADC values of necrotic and solid portions of lymph nodes were measured and compared. Receiver operating characteristic (ROC) analysis was employed to investigate whether ADC values could help to discriminate between the causes of cervical lymphadenopathy, and to obtain the optimal ADC threshold values. Results: The mean ADC values of the solid portions of metastatic nodes, lymphomatous nodes, and tuberculous nodes were (0.93 ± 0.16) × 10 −3 mm 2 /s, (0.64 ± 0.13) × 10 −3 mm 2 /s and (1.01 ± 0.11) × 10 −3 mm 2 /s, respectively (p −3 mm 2 /s and (1.25 ± 0.15) × 10 −3 mm 2 /s (p −3 , 0.98 × 10 −3 and 0.81 × 10 −3 mm 2 /s, respectively, and the sensitivities and specificities were 83 and 89%, 70 and 68%, 93 and 100%, respectively. By using ADC values of necrosis, the optimal ADC threshold value for distinguishing between metastasis and tuberculosis was 1.59 × 10 −3 mm 2 /s, and the sensitivity and specificity were 88 and 100%, respectively. Conclusion: The ADC values both of the necrotic and solid portions of the lymph nodes are useful in differentiation between the causes of cervical lymphadenopathy. The ADC value of necrosis is especially helpful in discriminating metastasis from tuberculosis

  20. Using the apparent diffusion coefficient to identifying MGMT promoter methylation status early in glioblastoma: importance of analytical method

    Energy Technology Data Exchange (ETDEWEB)

    Rundle-Thiele, Dayle [Centre for Clinical Research, University of Queensland, Brisbane, Queensland (Australia); Day, Bryan; Stringer, Brett [Brain Cancer Research Unit, Queensland Institute of Medical Research, Brisbane, Queensland (Australia); Fay, Michael [Department of Radiation Oncology, Royal Brisbane and Women' s Hospital, Brisbane, Queensland (Australia); Martin, Jennifer [Discipline of Clinical Pharmacology, School of Medicine and Public Health, University of Newcastle, Newcastle, New South Wales (Australia); Jeffree, Rosalind L [Department of Neurosurgery, Royal Brisbane and Women' s Hospital, Brisbane, Queensland (Australia); Thomas, Paul [Queensland PET Service, Royal Brisbane and Women' s Hospital, Brisbane, Queensland (Australia); Bell, Christopher [Centre for Clinical Research, University of Queensland, Brisbane, Queensland (Australia); Salvado, Olivier [CSIRO Digital Productivity Flagship, CSIRO, Herston, Queensland (Australia); Gal, Yaniv [Centre for Medical Diagnostic Technologies in Queensland, University of Queensland, Brisbane, Queensland (Australia); Coulthard, Alan [Discipline of Medical Imaging, University of Queensland, St Lucia, Queensland (Australia); Department of Medical Imaging, Royal Brisbane and Women' s Hospital, Brisbane, Queensland (Australia); Crozier, Stuart [Centre for Medical Diagnostic Technologies in Queensland, University of Queensland, Brisbane, Queensland (Australia); Rose, Stephen, E-mail: stephen.rose@csiro.au [CSIRO Digital Productivity Flagship, CSIRO, Herston, Queensland (Australia); Centre for Clinical Research, University of Queensland, Brisbane, Queensland (Australia)

    2015-06-15

    Accurate knowledge of O{sup 6}-methylguanine methyltransferase (MGMT) gene promoter subtype in patients with glioblastoma (GBM) is important for treatment. However, this test is not always available. Pre-operative diffusion MRI (dMRI) can be used to probe tumour biology using the apparent diffusion coefficient (ADC); however, its ability to act as a surrogate to predict MGMT status has shown mixed results. We investigated whether this was due to variations in the method used to analyse ADC. We undertook a retrospective study of 32 patients with GBM who had MGMT status measured. Matching pre-operative MRI data were used to calculate the ADC within contrast enhancing regions of tumour. The relationship between ADC and MGMT was examined using two published ADC methods. A strong trend between a measure of ‘minimum ADC’ and methylation status was seen. An elevated minimum ADC was more likely in the methylated compared to the unmethylated MGMT group (U = 56, P = 0.0561). In contrast, utilising a two-mixture model histogram approach, a significant reduction in mean measure of the ‘low ADC’ component within the histogram was associated with an MGMT promoter methylation subtype (P < 0.0246). This study shows that within the same patient cohort, the method selected to analyse ADC measures has a significant bearing on the use of that metric as a surrogate marker of MGMT status. Thus for dMRI data to be clinically useful, consistent methods of data analysis need to be established prior to establishing any relationship with genetic or epigenetic profiling.

  1. Comparison of NMR and Dynamic Light Scattering for Measuring Diffusion Coefficients of Formulated Insulin: Implications for Particle Size Distribution Measurements in Drug Products.

    Science.gov (United States)

    Patil, Sharadrao M; Keire, David A; Chen, Kang

    2017-11-01

    Particle size distribution, a measurable physicochemical quantity, is a critical quality attribute of drug products that needs to be controlled in drug manufacturing. The non-invasive methods of dynamic light scattering (DLS) and Diffusion Ordered SpectroscopY (DOSY) NMR can be used to measure diffusion coefficient and derive the corresponding hydrodynamic radius. However, little is known about their use and sensitivity as analytical tools for particle size measurement of formulated protein therapeutics. Here, DLS and DOSY-NMR methods are shown to be orthogonal and yield identical diffusion coefficient results for a homogenous monomeric protein standard, ribonuclease A. However, different diffusion coefficients were observed for five insulin drug products measured using the two methods. DOSY-NMR yielded an averaged diffusion coefficient among fast exchanging insulin oligomers, ranging between dimer and hexamer in size. By contrast, DLS showed several distinct species, including dimer, hexamer, dodecamer and other aggregates. The heterogeneity or polydisperse nature of insulin oligomers in formulation caused DOSY-NMR and DLS results to differ from each other. DLS measurements provided more quality attributes and higher sensitivity to larger aggregates than DOSY-NMR. Nevertheless, each method was sensitive to a different range of particle sizes and complemented each other. The application of both methods increases the assurance of complex drug quality in this similarity comparison.

  2. Role of the apparent diffusion coefficient measurement by diffusion weighted magnetic resonance imaging in the diagnosis of Fasciola hepatica in the liver.

    Science.gov (United States)

    Onur, Mehmet Ruhi; Ciçekçi, Mehtap; Kayali, Alperen; Kocakoç, Ercan; Aygün, Cem

    2011-12-01

    The aim of this study was to investigate the diagnostic role of the apparent diffusion coefficient (ADC) measurement in the diagnosis of focal parenchymal lesions and to understand the discriminating role of the ADC value for differentiating Fasciola lesions from other focal liver lesions. We measured ADC values of parenchymal lesions and liver parenchyma in 18 patients with Fasciola hepatica infestation at b 100, b 600, and b 1000 s/mm(2) gradients. We further measured average ADC values of hepatic metastases (n = 21), hepatocellular carcinomas (n = 21), cholangiocarcinomas (n = 7), hydatid cysts (n = 12), and focal nodular hyperplasia (FNH) (n = 12) and compared them with average ADC values for Fasciola hepatica. The differences between average ADC values of lesions (2.16 ± 0.36 × 10(-3) mm(2)/s) and parenchyma (1.64 ± 0.2 × 10(-3) mm(2)/s) at three gradients were statistically significant (P Fasciola hepatica lesions were significantly different from most of the other focal hepatic lesions, except FNH at all gradients and hydatid cyst at only the b 100 gradient. ADC measurement may be a complementary method in the diagnosis of Fasciola hepatica, and it may be used to differentiate these lesions from other focal liver lesions.

  3. Diffusion-weighted imaging of breast lesions: Region-of-interest placement and different ADC parameters influence apparent diffusion coefficient values

    Energy Technology Data Exchange (ETDEWEB)

    Bickel, Hubert; Pinker, Katja; Polanec, Stephan; Magometschnigg, Heinrich; Wengert, Georg; Spick, Claudio; Helbich, Thomas H.; Baltzer, Pascal [Medical University Vienna, Division of Molecular and Gender Imaging, Department of Biomedical Imaging and Image-Guided Therapy, Vienna (Austria); Bogner, Wolfgang [Medical University Vienna - MR Center of Excellence, Department of Biomedical Imaging and Image-Guided Therapy, Vienna (Austria); Bago-Horvath, Zsuzsanna [Medical University Vienna, Department of Pathology, Vienna (Austria)

    2017-05-15

    To investigate the influence of region-of-interest (ROI) placement and different apparent diffusion coefficient (ADC) parameters on ADC values, diagnostic performance, reproducibility and measurement time in breast tumours. In this IRB-approved, retrospective study, 149 histopathologically proven breast tumours (109 malignant, 40 benign) in 147 women (mean age 53.2) were investigated. Three radiologists independently measured minimum, mean and maximum ADC, each using three ROI placement approaches:1 - small 2D-ROI, 2 - large 2D-ROI and 3 - 3D-ROI covering the whole lesion. One reader performed all measurements twice. Median ADC values, diagnostic performance, reproducibility, and measurement time were calculated and compared between all combinations of ROI placement approaches and ADC parameters. Median ADC values differed significantly between the ROI placement approaches (p <.001). Minimum ADC showed the best diagnostic performance (AUC.928-.956), followed by mean ADC obtained from 2D ROIs (.926-.94). Minimum and mean ADC showed high intra- (ICC.85-.94) and inter-reader reproducibility (ICC.74-.94). Median measurement time was significantly shorter for the 2D ROIs (p <.001). ROI placement significantly influences ADC values measured in breast tumours. Minimum and mean ADC acquired from 2D-ROIs are useful for the differentiation of benign and malignant breast lesions, and are highly reproducible, with rapid measurement. (orig.)

  4. Role of the apparent diffusion coefficient measurement by diffusion weighted magnetic resonance imaging in the diagnosis of Fasciola hepatica in the liver

    International Nuclear Information System (INIS)

    Onur, M.R.; Cicekci, M.; Kayali, A.; Aygun, C.; Kocakoc, E.

    2011-01-01

    The aim of this study was to investigate the diagnostic role of the apparent diffusion coefficient (ADC) measurement in the diagnosis of focal parenchymal lesions and to understand the discriminating role of the ADC value for differentiating Fasciola lesions from other focal liver lesions. We measured ADC values of parenchymal lesions and liver parenchyma in 18 patients with Fasciola hepatica infestation at b 100, b 600, and b 1000 s/mm 2 gradients. We further measured average ADC values of hepatic metastases (n=21), hepatocellular carcinomas (n=21), cholangiocarcinomas (n=7), hydatid cysts (n=12), and focal nodular hyperplasia (FNH) (n=12) and compared them with average ADC values for Fasciola hepatica. The differences between average ADC values of lesions (2.16±0.36 x 10 -3 mm 2 /s) and parenchyma (1.64±0.2 x 10 -3 mm 2 /s) at three gradients were statistically significant (P<0.05). Mean ADC values of Fasciola hepatica lesions were significantly different from most of the other focal hepatic lesions, except FNH at all gradients and hydatid cyst at only the b 100 gradient. ADC measurement may be a complementary method in the diagnosis of Fasciola hepatica, and it may be used to differentiate these lesions from other focal liver lesions. (author)

  5. Change apparent diffusion coefficient immediately after recanalization through intra-arterial revascularization therapy in acute ischemic stroke

    International Nuclear Information System (INIS)

    Roh, Ji Eun; Yeom, Joeng A; Kim, Young Soo; Yoon, Chang Hyo; Park, Min Gyu; Park, Kyung Pil; Baik, Seung Kug

    2016-01-01

    Intra-arterial revascularization therapy (IART) for acute ischemic stroke has become increasingly popular recently. However, early change in apparent diffusion coefficient (ADC) values after full recanalization in human stroke has not received much attention. The aim of this study was to evaluate ADC changes immediately after interventional full-recanalization in patients with acute ischemic stroke. ADC values of 25 lesions from 18 acute ischemic stroke patients were recorded with both pre- and post-recanalization ADC maps. Measurement was done by placing region of interests over the representative images of the lesion. For analysis, lesions were divided into territorial infarction (TI) and watershed infarction (WI). Mean ADC values of the overall 25 lesions before IART were 415.12 × 10-6 mm 2 /sec, and increased to 619.08 × 10-6 mm 2 /sec after the IART. Average relative ADC (rADC) value for 22 TI increased from 0.59 to 0.92 (p < 0.000), whereas, average rADC value for 3 WI did not change significantly. There was a conspicuous increase of ADC values immediately after full-recanalization in TI lesions. On the other hand, WI lesions did not show significant change in ADC values after recanalization

  6. Effective conductivity, dielectric constant, and diffusion coefficient of digitized composite media via first-passage-time equations

    International Nuclear Information System (INIS)

    Torquato, S.; Kim, I.C.; Cule, D.

    1999-01-01

    We generalize the Brownian motion simulation method of Kim and Torquato [J. Appl. Phys. 68, 3892 (1990)] to compute the effective conductivity, dielectric constant and diffusion coefficient of digitized composite media. This is accomplished by first generalizing the first-passage-time equations to treat first-passage regions of arbitrary shape. We then develop the appropriate first-passage-time equations for digitized media: first-passage squares in two dimensions and first-passage cubes in three dimensions. A severe test case to prove the accuracy of the method is the two-phase periodic checkerboard in which conduction, for sufficiently large phase contrasts, is dominated by corners that join two conducting-phase pixels. Conventional numerical techniques (such as finite differences or elements) do not accurately capture the local fields here for reasonable grid resolution and hence lead to inaccurate estimates of the effective conductivity. By contrast, we show that our algorithm yields accurate estimates of the effective conductivity of the periodic checkerboard for widely different phase conductivities. Finally, we illustrate our method by computing the effective conductivity of the random checkerboard for a wide range of volume fractions and several phase contrast ratios. These results always lie within rigorous four-point bounds on the effective conductivity. copyright 1999 American Institute of Physics

  7. Comparison of Absolute Apparent Diffusion Coefficient (ADC) Values in ADC Maps Generated Across Different Postprocessing Software: Reproducibility in Endometrial Carcinoma.

    Science.gov (United States)

    Ghosh, Adarsh; Singh, Tulika; Singla, Veenu; Bagga, Rashmi; Khandelwal, Niranjan

    2017-12-01

    Apparent diffusion coefficient (ADC) maps are usually generated by builtin software provided by the MRI scanner vendors; however, various open-source postprocessing software packages are available for image manipulation and parametric map generation. The purpose of this study is to establish the reproducibility of absolute ADC values obtained using different postprocessing software programs. DW images with three b values were obtained with a 1.5-T MRI scanner, and the trace images were obtained. ADC maps were automatically generated by the in-line software provided by the vendor during image generation and were also separately generated on postprocessing software. These ADC maps were compared on the basis of ROIs using paired t test, Bland-Altman plot, mountain plot, and Passing-Bablok regression plot. There was a statistically significant difference in the mean ADC values obtained from the different postprocessing software programs when the same baseline trace DW images were used for the ADC map generation. For using ADC values as a quantitative cutoff for histologic characterization of tissues, standardization of the postprocessing algorithm is essential across processing software packages, especially in view of the implementation of vendor-neutral archiving.

  8. Automatic classification of cardioembolic and arteriosclerotic ischemic strokes from apparent diffusion coefficient datasets using texture analysis and deep learning

    Science.gov (United States)

    Villafruela, Javier; Crites, Sebastian; Cheng, Bastian; Knaack, Christian; Thomalla, Götz; Menon, Bijoy K.; Forkert, Nils D.

    2017-03-01

    Stroke is a leading cause of death and disability in the western hemisphere. Acute ischemic strokes can be broadly classified based on the underlying cause into atherosclerotic strokes, cardioembolic strokes, small vessels disease, and stroke with other causes. The ability to determine the exact origin of an acute ischemic stroke is highly relevant for optimal treatment decision and preventing recurrent events. However, the differentiation of atherosclerotic and cardioembolic phenotypes can be especially challenging due to similar appearance and symptoms. The aim of this study was to develop and evaluate the feasibility of an image-based machine learning approach for discriminating between arteriosclerotic and cardioembolic acute ischemic strokes using 56 apparent diffusion coefficient (ADC) datasets from acute stroke patients. For this purpose, acute infarct lesions were semi-atomically segmented and 30,981 geometric and texture image features were extracted for each stroke volume. To improve the performance and accuracy, categorical Pearson's χ2 test was used to select the most informative features while removing redundant attributes. As a result, only 289 features were finally included for training of a deep multilayer feed-forward neural network without bootstrapping. The proposed method was evaluated using a leave-one-out cross validation scheme. The proposed classification method achieved an average area under receiver operator characteristic curve value of 0.93 and a classification accuracy of 94.64%. These first results suggest that the proposed image-based classification framework can support neurologists in clinical routine differentiating between atherosclerotic and cardioembolic phenotypes.

  9. [A case of cerebral venous thrombosis with reversible brain parenchymal lesions: usefulness of diffusion weighted imaging and measurement of apparent diffusion coefficient].

    Science.gov (United States)

    Kuwahara, S; Abe, T; Kawada, M; Uga, S; Shimizu, K

    2001-01-01

    A 47-year-old man with a history of thrombophlebitis of his left leg for several years presented with a mild left hemiparesis and ipsilateral hypesthesia. Magnetic resonance imaging showed subacute thrombosis of the superior sagittal sinus and a cortical vein of the right cerebral hemisphere. A linear hyperintense area was found in the white matter of the right postcentral gyrus on T 2- and diffusion weighted axial imagings on the 7 days after the onset. The patient was treated conservatively, and his clinical course was uneventful. His neurological dysfunctions recovered within approximately three weeks after the onset. The white matter lesion in the right postcentral gyrus also disappeared one month later. The apparent diffusion coefficients (ADCs) in the white matter of the pre- and postcentral gyrus were measured bilaterally on the ADC mapping imaging. In the subacute stage, the ADC values in the white matter of the right pre- and postcentral gyrus were 0.50 x 10(-3) mm2/sec and 0.91 x 10(-3) mm2/sec, respectively. The %ADC indicating the ratio of ADC value of the lesion to that of the contralateral brain tissue was calculated. The %ADCs in the white matter of the pre- and postcentral gyrus were 64.9% and 124.5% respectively. In the chronic stage, the ADC values in the white matter of the right pre- and postcentral gyrus were 0.96 x 10(-3) mm2/sec and 0.99 x 10(-3) mm2/sec, and the %ADCs improved to 106.7% and 106.5% respectively. The lesions in the white matter of the right pre- and postcentral gyrus were reversible. The former was thought to be mainly ascribed to cellular edema and the latter was vasogenic edema. The present case showed when %ADC of the ischemic lesion in cerebral venous thrombosis was higher than 60%-70%, conservative therapy alone is sufficient effective for the improvement of neurological deficits.

  10. Apparent Diffusion Coefficient Value of Diffusion-Weighted Imaging for Hepatocellular Carcinoma: Correlation with the Histologic Differentiation and the Expression of Vascular Endothelial Growth Factor

    International Nuclear Information System (INIS)

    Heo, Suk Hee; Jeong, Yong Yeon; Kim, Jin Woong; Lim, Hyo Soon; Lee, Jae Hyuk; Koh, Yang Seok; Cho, Chol Kyoon; Kang, Heoung Keun; Shin, Sang Soo

    2010-01-01

    To evaluate whether the histopathological differentiation and the expression of vascular endothelial growth factor (VEGF) of hepatocellular carcinoma (HCC) do show correlation with the apparent diffusion coefficient (ADC) value on diffusion-weighted imaging (DWI). Twenty-seven HCCs from 27 patients who had undergone preoperative liver MRI (1.5T) and surgical resection were retrospectively reviewed. DWI was obtained with a single-shot, echo-planar imaging sequence in the axial plane (b values: 0 and 1,000 sec/mm 2 ). On DWIs, the ADC value of the HCCs was measured by one radiologist, who was kept 'blinded' to the histological findings. Histopathologically, the differentiation was classified into well (n = 9), moderate (n = 9) and poor (n = 9). The expression of VEGF was semiquantitatively graded as grade 0 (n = 8), grade 1 (n = 9) and grade 2 (n = 10). We analyzed whether the histopathological differentiation and the expression of VEGF of the HCC showed correlation with the ADC value on DWI. The mean ADC value of the poorly-differentiated HCCs (0.9 ± 0.13x 10 -3 mm 2 /s) was lower than those of the well-differentiated HCCs (1.2 ± 0.22x 10 -3 mm 2 /s) (p = 0.031) and moderately-differentiated HCCs (1.1 ± 0.01x10 -3 mm 2 /s) (p = 0.013). There was a significant correlation between the differentiation and the ADC value of the HCCs (r = -0.51, p = 0.012). The mean ADC of the HCCs with a VEGF expression grade of 0, 1 and 2 was 1.1 ± 0.17, 1.1 ± 0.21 and 1.1 ± 0.18x10 -3 mm 2 /s, respectively. The VEGF expression did not show correlation with the ADC value of the HCCs (r = 0.07, p = 0.74). The histopathological differentiation of HCC shows inverse correlation with the ADC value. Therefore, DWI with ADC measurement may be a valuable tool for noninvasively predicting the differentiation of HCC

  11. Determination of Hydrogen Diffusion Coefficients in Fused Silica From 23 to 250°C Using Raman Spectroscopy

    Science.gov (United States)

    Shang, L.; Chou, I.; Lu, W.; Burruss, R. C.

    2008-12-01

    The oxygen buffer technique is routinely used in experimental studies of redox sensitive geochemical reactions at elevated pressures (P) and temperatures (T). However, this technique is limited to T above about 400°C due to the low permeability of sample containers (Pt or Ag-Pd alloys) to hydrogen at lower T. Preliminary results of Chou et al. (Geochim. Cosmochim. Acta, 2008, doi:10.1016/j.gca.2008.07.030) indicate that the use of fused silica capillary (FSC) container may extend this technique to lower T. In this study, hydrogen diffusion coefficients (D) in FSC were determined from 23 to 250°C by measuring the loss of hydrogen from the FSC containers (0.3 mm OD, 0.1 mm ID, and ~10 mm long) with Raman spectroscopy using CO2 as an internal standard. First, CO2 was loaded cryogenically in a FSC capsule (Chou et al., ibid.). The capsule was then inserted in a protective ceramic tube, sealed in a gold capsule containing Fe powder and water, and heated at 300°C under 100 MPa of Ar external P in a cold-seal pressure vessel for several days allowing H2 to diffuse into the capsule. After quench, the Raman spectra were collected and the initial relative concentration of hydrogen in the silica capsule was derived from the peak height ratios between H2 (near 587 cm-1) and CO2 (near 1387 cm- 1). The sample capsule was then heated at a fixed T at one atmosphere to let H2 diffuse out of the capsule, and the changes of hydrogen concentration were monitored by Raman spectroscopy after quench. This process was repeated with different heating durations at 23 (room T), 50, 102, 157, 200, and 250°C. The values of D (in cm2s-1) in FSC were obtained by fitting the observed changes of hydrogen concentration to an equation based on Fick's second law. Our results can be represented by: Ln D (±0.14) = (-39810/RT) - 9.5491 (r2 = 0.9985) where R is the gas constant, and T in Kelvin. The slope corresponds to an activation energy of 39.81 kJ/mol. Our D values are about a half order of

  12. Combined inverse-forward artificial neural networks for fast and accurate estimation of the diffusion coefficients of cartilage based on multi-physics models

    NARCIS (Netherlands)

    Arbabi, Vahid|info:eu-repo/dai/nl/364184892; Pouran, B; Weinans, Harrie|info:eu-repo/dai/nl/087198622; Zadpoor, Amir A

    2016-01-01

    Analytical and numerical methods have been used to extract essential engineering parameters such as elastic modulus, Poisson׳s ratio, permeability and diffusion coefficient from experimental data in various types of biological tissues. The major limitation associated with analytical techniques is

  13. Influence of Non-Perfect Step Input Concentration at the Feed Side of the Membrane Surface on the Diffusion Coefficient Evaluation

    Czech Academy of Sciences Publication Activity Database

    Čermáková, Jiřina; Fialová, Kateřina; Petričkovič, Roman; Kudrna, V.; Uchytil, Petr

    2006-01-01

    Roč. 15, č. 3 (2006), s. 246-251 ISSN 1022-1344 R&D Projects: GA AV ČR(CZ) 1QS401250509; GA AV ČR(CZ) IAA4072402 Institutional research plan: CEZ:AV0Z40720504 Keywords : diffusion coefficient * flux * dispersion Subject RIV: CI - Industrial Chemistry, Chemical Engineering Impact factor: 1.073, year: 2006

  14. Measuring localization and diffusion coefficients of basolateral proteins in lateral versus basal membranes using functionalized substrates and kICS analysis

    DEFF Research Database (Denmark)

    Marlar, Saw; Christensen, Eva Arnspang; Pedersen, Gitte Albinus

    2014-01-01

    Micropatterning enabled semiquantitation of basolateral proteins in lateral and basal membranes of the same cell. Lateral diffusion coefficients of basolateral aquaporin-3 (AQP3-EGFP) and EGFP-AQP4 were extracted from “lateral” and “basal” membranes using identical live-cell imaging and k...

  15. Evaluation of the normal-to-diseased apparent diffusion coefficient ratio as an indicator of prostate cancer aggressiveness

    International Nuclear Information System (INIS)

    Lebovici, Andrei; Sfrangeu, Silviu A; Feier, Diana; Caraiani, Cosmin; Lucan, Ciprian; Suciu, Mihai; Elec, Florin; Iacob, Gheorghita; Buruian, Mircea

    2014-01-01

    We tested the feasibility of a simple method for assessment of prostate cancer (PCa) aggressiveness using diffusion-weighted magnetic resonance imaging (MRI) to calculate apparent diffusion coefficient (ADC) ratios between prostate cancer and healthy prostatic tissue. The requirement for institutional review board approval was waived. A set of 20 standardized core transperineal saturation biopsy specimens served as the reference standard for placement of regions of interest on ADC maps in tumorous and normal prostatic tissue of 22 men with PCa (median Gleason score: 7; range, 6–9). A total of 128 positive sectors were included for evaluation. Two diagnostic ratios were computed between tumor ADCs and normal sector ADCs: the ADC peripheral ratio (the ratio between tumor ADC and normal peripheral zone tissue, ADC-PR), and the ADC central ratio (the ratio between tumor ADC and normal central zone tissue, ADC-CR). The performance of the two ratios in detecting high-risk tumor foci (Gleason 8 and 9) was assessed using the area under the receiver operating characteristic curve (AUC). Both ADC ratios presented significantly lower values in high-risk tumors (0.48 ± 0.13 for ADC-CR and 0.40 ± 0.09 for ADC-PR) compared with low-risk tumors (0.66 ± 0.17 for ADC-CR and 0.54 ± 0.09 for ADC-PR) (p < 0.001) and had better diagnostic performance (ADC-CR AUC = 0.77, sensitivity = 82.2%, specificity = 66.7% and ADC-PR AUC = 0.90, sensitivity = 93.7%, specificity = 80%) than stand-alone tumor ADCs (AUC of 0.75, sensitivity = 72.7%, specificity = 70.6%) for identifying high-risk lesions. The ADC ratio as an intrapatient-normalized diagnostic tool may be better in detecting high-grade lesions compared with analysis based on tumor ADCs alone, and may reduce the rate of biopsies

  16. Why prostate tumour delineation based on apparent diffusion coefficient is challenging: an exploration of the tissue microanatomy.

    Science.gov (United States)

    Borren, Alie; Moman, Maaike R; Groenendaal, Greetje; Boeken Kruger, Arto E; van Diest, Paul J; van der Groep, Petra; van der Heide, Uulke A; van Vulpen, Marco; Philippens, Marielle E P

    2013-11-01

    Focal boosting of prostate tumours to improve outcome, requires accurate tumour delineation. For this, the apparent diffusion coefficient (ADC) derived from diffusion-weighted MR imaging (DWI) seems a useful tool. On voxel level, the relationship between ADC and histological presence of tumour is, however, ambiguous. Therefore, in this study the relationship between ADC and histological variables was investigated on voxel level to understand the strengths and limitations of DWI for prostate tumour delineation. Twelve radical prostatectomy patients underwent a pre-operative 3.0T DWI exam and the ADC was calculated. From whole-mount histological sections cell density and glandular area were retrieved for every voxel. The distribution of all variables was described for tumour, peripheral zone (PZ) and central gland (CG) on regional and voxel level. Correlations between variables and differences between regions were calculated. Large heterogeneity of ADC on voxel level was observed within tumours, between tumours and between patients. This heterogeneity was reflected by the distribution of cell density and glandular area. On regional level, tumour was different from PZ having higher cell density (p = 0.007), less glandular area (p = 0.017) and lower ADCs (p = 0.017). ADC was correlated with glandular area (r = 0.402) and tumour volume (r = -0.608), but not with Gleason score. ADC tended to decrease with increasing cell density (r = -0.327, p = 0.073). On voxel level, correlations between ADC and histological variables varied among patients, for cell density ranging from r = -0.439 to r = 0.261 and for glandular area from r = 0.593 to r = 0.207. The variation in ADC can to a certain extent be explained by the variation in cell density and glandular area. The ADC is highly heterogeneous, which reflects the heterogeneity of malignant and benign prostate tissue. This heterogeneity might however obscure small tumours or parts of tumours. Therefore, DWI has to be used in the

  17. Simultaneous measurement of thermal diffusivity and effective infrared absorption coefficient in IR semitransparent and semiconducting n-CdMgSe crystals using photothermal radiometry

    Energy Technology Data Exchange (ETDEWEB)

    Pawlak, M., E-mail: mpawlak@fizyka.umk.pl [Institute of Physics, Faculty of Physics, Astronomy and Informatics, Nicolaus Copernicus University, Grudziądzka 5/7, Toruń (Poland); Maliński, M. [Department of Electronics and Computer Science, Koszalin University of Technology, 2 Śniadeckich St., Koszalin 75-453 (Poland)

    2015-01-10

    Highlights: • The new method of determination of the effective infrared absorption coefficient is presented. • The method can be used for transparent samples for the excitation radiation. • The effect of aluminum foil on the PTR signal in a transmission configuration is discussed. - Abstract: In this paper we propose a new procedure of simultaneous estimation of the effective infrared optical absorption coefficient and the thermal diffusivity of solid state samples using the photothermal infrared radiometry method in the transmission configuration. The proposed procedure relies on the analysis of the frequency dependent signal obtained from the samples covered with thin aluminum foil. This method can be applied for both optically opaque and transparent samples. The proposed method is illustrated with the results of the thermal diffusivity and the effective IR absorption coefficient obtained for several Cd{sub 1−x}Mg{sub x}Se crystals.

  18. Peritumoral apparent diffusion coefficients for prediction of lymphovascular invasion in clinically node-negative invasive breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Mori, Naoko; Mugikura, Shunji; Takasawa, Chiaki; Shimauchi, Akiko; Ota, Hideki; Takase, Kei; Takahashi, Shoki [Tohoku University Graduate School of Medicine, Department of Diagnostic Radiology, Sendai (Japan); Miyashita, Minoru; Ishida, Takanori [Tohoku University Graduate School of Medicine, Department of Surgical Oncology, Sendai (Japan); Kasajima, Atsuko [Tohoku University Graduate School of Medicine, Department of Pathology, Sendai (Japan); Kodama, Tetsuya [Tohoku University Graduate School of Medicine, Department of Biomedical Engineering, Sendai (Japan)

    2016-02-15

    To evaluate whether visual assessment of T2-weighted imaging (T2WI) or an apparent diffusion coefficient (ADC) could predict lymphovascular invasion (LVI) status in cases with clinically node-negative invasive breast cancer. One hundred and thirty-six patients with 136 lesions underwent MRI. Visual assessment of T2WI, tumour-ADC, peritumoral maximum-ADC and the peritumour-tumour ADC ratio (the ratio between them) were compared with LVI status of surgical specimens. No significant relationship was found between LVI and T2WI. Tumour-ADC was significantly lower in the LVI-positive (n = 77, 896 ± 148 x 10{sup -6} mm{sup 2}/s) than the LVI-negative group (n = 59, 1002 ± 163 x 10{sup -6} mm{sup 2}/s; p < 0.0001). Peritumoral maximum-ADC was significantly higher in the LVI-positive (1805 ± 355 x 10{sup -6} mm{sup 2}/s) than the LVI-negative group (1625 ± 346 x 10{sup -6} mm{sup 2}/s; p = 0.0003). Peritumour-tumour ADC ratio was significantly higher in the LVI-positive (2.05 ± 0.46) than the LVI-negative group (1.65 ± 0.40; p < 0.0001). Receiver operating characteristic curve analysis revealed that the area under the curve (AUC) of the peritumour-tumour ADC ratio was the highest (0.81). The most effective threshold for the peritumour-tumour ADC ratio was 1.84, and the sensitivity, specificity, positive predictive value and negative predictive value were 77 % (59/77), 76 % (45/59), 81 % (59/73) and 71 % (45/63), respectively. We suggest that the peritumour-tumour ADC ratio can assist in predicting LVI status on preoperative imaging. (orig.)

  19. Large-volume low apparent diffusion coefficient lesions predict poor survival in bevacizumab-treated glioblastoma patients

    Science.gov (United States)

    Zhang, Myron; Gulotta, Bryanna; Thomas, Alissa; Kaley, Thomas; Karimi, Sasan; Gavrilovic, Igor; Woo, Kaitlin M.; Zhang, Zhigang; Arevalo-Perez, Julio; Holodny, Andrei I.; Rosenblum, Marc; Young, Robert J.

    2016-01-01

    Background Glioblastomas treated with bevacizumab may develop low-signal apparent diffusion coefficient (low-ADC) lesions, which may reflect increased tumor cellularity or atypical necrosis. The purpose of this study was to examine the relationship between low-ADC lesions and overall survival (OS). We hypothesized that growing low-ADC lesions would be associated with shorter OS. Methods We retrospectively identified 52 patients treated with bevacizumab for the first (n = 42, 81%) or later recurrence of primary glioblastoma, who had low-ADC lesions and 2 post-bevacizumab scans ≤90 days apart. Low-ADC lesion volumes were measured, and normalized 5th percentile histogram low-ADC values were recorded. Using OS as the primary endpoint, semiparametric Cox models were fitted to ascertain univariate and multivariate hazard ratios (HRs) with significance at P = .05. Results Median OS was 9.1 months (95% CI = 7.2–14.3). At the second post-bevacizumab scan, the volume of the low-ADC lesion (median: 12.94 cm3) was inversely associated with OS, with larger volumes predicting shorter OS (HR = 1.014 [95% CI = 1.003–1.025], P = .009). The percent change in low-ADC volume (median: 6.8%) trended toward increased risk of death with growing volumes (P = .08). Normalized 5th percentile low-ADC value and its percent change were not associated with OS (P > .51). Also correlated with shorter OS were the pre-bevacizumab nonenhancing volume (P = .025), the first post-bevacizumab enhancing volume (P = .040), and the second post-bevacizumab enhancing volume (P = .004). Conclusions The volume of low-ADC lesions at the second post-bevacizumab scan predicted shorter OS. This suggests that low-ADC lesions may be considered important imaging markers and included in treatment decision algorithms. PMID:26538618

  20. Diffusion coefficients for Tl, Pb, Cd, In, Zn, Bi, As, Mo and Sb in hydrous rhyolite at 100-200 MPa

    Science.gov (United States)

    Berlo, Kim; Brooker, Richard; Wilke, Max

    2014-05-01

    A series of experiments have been conducted to determine the diffusivities of Tl, Pb, Cd, In, Zn, Bi, As, Mo and Sb in hydrous rhyolitic melt. Diffusion experiments used two adjoining glass cylinder of the same hydrous composition, one doped with the elements of interest at ~ 100 ppm. These couples were rapidly heated to 850, 1000 and 1150°C at 100-200 MPa for a few hours. After quenching the sectioned charges were analyzed by both synchrotron XRF (The Diamond Light Source) and LA-ICP-MS (University of Oxford). The data shows excellent correlation between these two techniques. The diffusion profiles were fitted to a 1-D diffusion couple equation to determine the diffusivities and fitting to the different temperature runs defined the Arrhenius parameters. We find that for 850°C the diffusion coefficients follow the trend Tl>Pb>Cd>Zn>In>Bi>As>Sb>Mo. Additional experiments were performed with either S or Cl added (to both sides of the diffusion couple). In general S increases the diffusion rate of all metals except Mo and Sb, which diffuse slower in the presence of S. Chlorine also speeds up the diffusion of metals with the exception of In, Mo and Sb. The systematic change in diffusivities of these metals and their different behaviour in the presence of the ligands that are also observed to be significant in volcanic gases, are important in determining the distribution of these metals during degassing (e.g. MacKenzie and Canil, 2008). This is particularly important in a dynamic environment such as a volcanic conduit. There are also implications for economic exploration and well as hazard mitigation.

  1. Data-driven analysis for the temperature and momentum dependence of the heavy-quark diffusion coefficient in relativistic heavy-ion collisions

    Science.gov (United States)

    Xu, Yingru; Bernhard, Jonah E.; Bass, Steffen A.; Nahrgang, Marlene; Cao, Shanshan

    2018-01-01

    By applying a Bayesian model-to-data analysis, we estimate the temperature and momentum dependence of the heavy quark diffusion coefficient in an improved Langevin framework. The posterior range of the diffusion coefficient is obtained by performing a Markov chain Monte Carlo random walk and calibrating on the experimental data of D -meson RAA and v2 in three different collision systems at the Relativistic Heavy-Ion Collidaer (RHIC) and the Large Hadron Collider (LHC): Au-Au collisions at 200 GeV and Pb-Pb collisions at 2.76 and 5.02 TeV. The spatial diffusion coefficient is found to be consistent with lattice QCD calculations and comparable with other models' estimation. We demonstrate the capability of our improved Langevin model to simultaneously describe the RAA and v2 at both RHIC and the LHC energies, as well as the higher order flow coefficient such as D meson v3. We show that by applying a Bayesian analysis, we are able to quantitatively and systematically study the heavy flavor dynamics in heavy-ion collisions.

  2. Osmotic and activity coefficients in the binary solutions of 1-butyl-3-methylimidazolium chloride and bromide in methanol or ethanol at T = 298.15 K from isopiestic measurements

    International Nuclear Information System (INIS)

    Sardroodi, Jaber Jahanbin; Azamat, Jafar; Atabay, Maryam

    2011-01-01

    Highlights: → The osmotic coefficients of the solutions of 1-butyl-3-methylimidazolium chloride and bromide in ethanol and methanol have been measured. → Measured osmotic coefficients were correlated using NRTL and Pitzer models. → Vapor pressures were evaluated from the correlated osmotic coefficients. → Model parameters have been interpreted in terms of ion-ion and ion-solvent interactions. - Abstract: Osmotic coefficients of the binary solutions of two room-temperature ionic liquids (1-butyl-3-methylimidazolium chloride and bromide) in methanol and ethanol have been measured at T = 298.15 K by the isopiestic method. The experimental osmotic coefficient data have been correlated using a forth-order polynomial in terms of (molality) 0.5 , with both, ion interaction model of Pitzer and electrolyte non-random two liquid (e-NRTL) model of Chen. The values of vapor pressures of above-mentioned solutions have been calculated from the osmotic coefficients. The model parameters fitted to the experimental osmotic coefficients have been used for prediction of the mean ionic activity coefficients of those ionic liquids in methanol and ethanol.

  3. A third-order computational method for numerical fluxes to guarantee nonnegative difference coefficients for advection-diffusion equations in a semi-conservative form

    Science.gov (United States)

    Sakai, K.; Watabe, D.; Minamidani, T.; Zhang, G. S.

    2012-10-01

    According to Godunov theorem for numerical calculations of advection equations, there exist no higher-order schemes with constant positive difference coefficients in a family of polynomial schemes with an accuracy exceeding the first-order. We propose a third-order computational scheme for numerical fluxes to guarantee the non-negative difference coefficients of resulting finite difference equations for advection-diffusion equations in a semi-conservative form, in which there exist two kinds of numerical fluxes at a cell surface and these two fluxes are not always coincident in non-uniform velocity fields. The present scheme is optimized so as to minimize truncation errors for the numerical fluxes while fulfilling the positivity condition of the difference coefficients which are variable depending on the local Courant number and diffusion number. The feature of the present optimized scheme consists in keeping the third-order accuracy anywhere without any numerical flux limiter. We extend the present method into multi-dimensional equations. Numerical experiments for advection-diffusion equations showed nonoscillatory solutions.

  4. Diffusion in liquids a theoretical and experimental study

    CERN Document Server

    Tyrrell, H J V

    1984-01-01

    Diffusion in Liquids: A Theoretical and Experimental Study aims to discuss the principles, applications, and advances in the field of diffusion, thermal diffusion, and thermal conduction in liquid systems. The book covers topics such as the principles of non-equilibrium thermodynamics; diffusion in binary and multicompetent systems; and experimental methods of studying diffusion processes in liquids. Also covered in the book are topics such as the theoretical interpretations of diffusion coefficients; hydrodynamic and kinetic theories; and diffusion in electrolyte systems. The text is recommen

  5. Energy dependence of the radial diffusion coefficient and spectra of inner radiation belt particles: analytic solutions and comparison with numerical results

    International Nuclear Information System (INIS)

    Westphalen, H.; Spjeldvik, W.N.

    1982-01-01

    We present a theoretical method by which the energy dependence of the radial diffusion coefficient D/sub L/L may be deducted from spectral observations of the particle population at the inner edge of the earth's radiation belts. This region has previously been analyzed with numerical techniques (for a review see, e.g., Walt (1971)); in this report we give an analytical treatment that illustrates characteristic limiting cases in the L shell range where the time scale of Coulomb losses is substantially shorter than that of radial diffusion (Lapprox.1--2). We demonstrate both analytically and numerically that the particle spectra there are shaped by the energy dependence of D/sub L/L regardless of the spectral shapes of the particle populations diffusing inward from the outer radiation zone, so that from observed spectra the energy dependence of the diffusion coefficient can be determined. To insure realistic simulations, inner zone data obtained from experiments on the DIAL, AZUR, and ESRO 2 spacecraft have been used as boundary conditions. We report excellent agreement between analytic and numerical results

  6. A predictive method for crude oil volatile organic compounds emission from soil: evaporation and diffusion behavior investigation of binary gas mixtures.

    Science.gov (United States)

    Wang, Haijing; Fischer, Thomas; Wieprecht, Wolfgang; Möller, Detlev

    2015-05-01

    Due to their mobility and toxicity, crude oil volatile organic compounds (VOCs) are representative components for oil pipeline contaminated sites detection. Therefore, contaminated location risk assessment, with airborne light detection and ranging (LIDAR) survey, in particular, requires ground-based determinative methods for oil VOCs, the interaction between oil VOCs and soil, and information on how they diffuse from underground into atmosphere. First, we developed a method for determination of crude oil VOC binary mixtures (take n-pentane and n-hexane as examples), taking synergistic effects of VOC mixtures on polydimethylsiloxane (PDMS) solid-phase microextraction (SPME) fibers into consideration. Using this method, we further aim to extract VOCs from small volumes, for example, from soil pores, using a custom-made sampling device for nondestructive SPME fiber intrusion, and to study VOC transport through heterogeneous porous media. Second, specific surface Brunauer-Emmett-Teller (BET) analysis was conducted and used for estimation of VOC isotherm parameters in soil. Finally, two models were fitted for VOC emission prediction, and the results were compared to the experimental emission results. It was found that free diffusion mode worked well, and an empirical correction factor seems to be needed for the other model to adapt to our condition for single and binary systems.

  7. The signature of diffusion in the binary system of omicron Leonis: a key for AmFm scenarios?

    Czech Academy of Sciences Publication Activity Database

    Gebran, M.; Hadrava, Petr; Jasniewicz, G.; Richard, O.

    2015-01-01

    Roč. 357, č. 2 (2015), 137/1-137/9 ISSN 0004-640X R&D Projects: GA ČR GB14-37086G Institutional support: RVO:67985815 Keywords : binaries * spectroscopic * stars Subject RIV: BN - Astronomy, Celestial Mechanics, Astrophysics Impact factor: 1.678, year: 2015

  8. A tumour control probability model for radiotherapy of prostate cancer using magnetic resonance imaging-based apparent diffusion coefficient maps

    DEFF Research Database (Denmark)

    Casares Magaz, Oscar; Van der Heide, Uulke A; Rørvik, Jarle

    2016-01-01

    Background and purpose: Standard tumour control probability (TCP) models assume uniform tumour cell density across the tumour. The aim of this study was to develop an individualised TCP model by including index-tumour regions extracted form multi-parametric magnetic resonance imaging (MRI...... density: a linear, a binary and a sigmoid relation. All TCP models were based on linear- quadratic cell survival curves assuming a/b = 1.93 Gy (consistent with a recent meta-analysis) and a set to obtain a 70% of TCP when 77 Gy was delivered to the entire prostate in 35 fractions (a = 0.18 Gy?1). Results......: Overall, TCP curves based on ADC maps showed larger differences between individuals than those assuming uniform cell densities. The range of the dose required to reach 50% TCP across the patient cohort was 20.1 Gy, 18.7 Gy and 13.2 Gy using an MRI-based voxel density (linear, binary and sigmoid approach...

  9. Formation of multiple stoichiometric phases in binary systems by combined bulk and grain boundary diffusion: Experiments and model

    Czech Academy of Sciences Publication Activity Database

    Svoboda, Jiří; Fischer, F. D.; Schillinger, W.

    2013-01-01

    Roč. 61, č. 1 (2013), s. 32-39 ISSN 1359-6454 R&D Projects: GA ČR GAP204/10/1784 Institutional support: RVO:68081723 Keywords : Bulk diffusion * Thermodynamic modeling * Intermetallic phases * Grain-boundary diffusion Subject RIV: BJ - Thermodynamics Impact factor: 3.940, year: 2013

  10. Effect of particle size on dc conductivity, activation energy and diffusion coefficient of lithium iron phosphate in Li-ion cells

    Directory of Open Access Journals (Sweden)

    T.V.S.L. Satyavani

    2016-03-01

    Full Text Available Cathode materials in nano size improve the performance of batteries due to the increased reaction rate and short diffusion lengths. Lithium Iron Phosphate (LiFePO4 is a promising cathode material for Li-ion batteries. However, it has its own limitations such as low conductivity and low diffusion coefficient which lead to high impedance due to which its application is restricted in batteries. In the present work, increase of conductivity with decreasing particle size of LiFePO4/C is studied. Also, the dependence of conductivity and activation energy for hopping of small polaron in LiFePO4/C on variation of particle size is investigated. The micro sized cathode material is ball milled for different durations to reduce the particle size to nano level. The material is characterized for its structure and particle size. The resistivities/dc conductivities of the pellets are measured using four probe technique at different temperatures, up to 150 °C. The activation energies corresponding to different particle sizes are calculated using Arrhenius equation. CR2032 cells are fabricated and electrochemical characteristics, namely, ac impedance and diffusion coefficients, are studied.

  11. Magnetic resonance imaging in children with sickle cell disease - detecting alterations in the apparent diffusion coefficient in hips with avascular necrosis

    Energy Technology Data Exchange (ETDEWEB)

    MacKenzie, John D. [Children' s Hospital of Philadelphia, Department of Pediatric Radiology, Philadelphia, PA (United States); UCSF Benioff Children' s Hospital, Department of Radiology and Biomedical Imaging, San Francisco, CA (United States); Hernandez, Andrea; Pena, Andres; Khrichenko, Dmitry; Gonzalez, Leonardo; Jaramillo, Diego [Children' s Hospital of Philadelphia, Department of Pediatric Radiology, Philadelphia, PA (United States); Ruppert, Kai [Children' s Hospital of Philadelphia, Department of Pediatric Radiology, Philadelphia, PA (United States); University of Virginia, Department of Radiology, Charlottesville, VA (United States); Jawad, Abbas F. [Children' s Hospital of Philadelphia, Department of Pediatrics, Philadelphia, PA (United States); Wells, Lawrence [Children' s Hospital of Philadelphia, Department of Orthopedics, Philadelphia, PA (United States); Smith-Whitley, Kim [Children' s Hospital of Philadelphia, Department of Hematology, Philadelphia, PA (United States)

    2012-06-15

    Avascular necrosis (AVN) is a common morbidity in children with sickle cell disease (SCD) that leads to pain and joint immobility. However, the diagnosis is often uncertain or delayed. To examine the ability of apparent diffusion coefficient (ADC) measurements on diffusion-weighted imaging to detect AVN in children with SCD. ADC values were calculated at the hips of normal children (n = 19) and children with SCD who were either asymptomatic with no known previous hip disease (n = 13) or presented for the first time with clinical symptoms of hip pathology (n = 12). ADC values were compared for differences among groups with and without AVN using non-parametric statistical methods. The ADC values were elevated in the hips of children with AVN (median ADC = 1.57 x 10{sup -3} mm{sup 2}/s [95% confidence interval = 0.86-2.10]) and differed significantly in pairwise comparisons (all P < 0.05) from normal children (0.74 [0.46-0.98]), asymptomatic children with SCD (0.55 [0.25-0.85]), and SCD children who had symptoms referable to their hips but did not show findings of hip AVN on conventional MRI or radiographs (0.46 [0.18-0.72]). Children with sickle cell disease have elevated apparent diffusion coefficient values in their affected hips on initial diagnosis of avascular necrosis. (orig.)

  12. Magnetic resonance imaging in children with sickle cell disease - detecting alterations in the apparent diffusion coefficient in hips with avascular necrosis

    International Nuclear Information System (INIS)

    MacKenzie, John D.; Hernandez, Andrea; Pena, Andres; Khrichenko, Dmitry; Gonzalez, Leonardo; Jaramillo, Diego; Ruppert, Kai; Jawad, Abbas F.; Wells, Lawrence; Smith-Whitley, Kim

    2012-01-01

    Avascular necrosis (AVN) is a common morbidity in children with sickle cell disease (SCD) that leads to pain and joint immobility. However, the diagnosis is often uncertain or delayed. To examine the ability of apparent diffusion coefficient (ADC) measurements on diffusion-weighted imaging to detect AVN in children with SCD. ADC values were calculated at the hips of normal children (n = 19) and children with SCD who were either asymptomatic with no known previous hip disease (n = 13) or presented for the first time with clinical symptoms of hip pathology (n = 12). ADC values were compared for differences among groups with and without AVN using non-parametric statistical methods. The ADC values were elevated in the hips of children with AVN (median ADC = 1.57 x 10 -3 mm 2 /s [95% confidence interval = 0.86-2.10]) and differed significantly in pairwise comparisons (all P < 0.05) from normal children (0.74 [0.46-0.98]), asymptomatic children with SCD (0.55 [0.25-0.85]), and SCD children who had symptoms referable to their hips but did not show findings of hip AVN on conventional MRI or radiographs (0.46 [0.18-0.72]). Children with sickle cell disease have elevated apparent diffusion coefficient values in their affected hips on initial diagnosis of avascular necrosis. (orig.)

  13. Diffusion Coefficients and Other Transport Characteristics of Peculiarly Shaped Porous Materials in the Single Pellet-String Column

    Czech Academy of Sciences Publication Activity Database

    Šolcová, Olga; Soukup, Karel; Schneider, Petr

    2006-01-01

    Roč. 91, 1-3 (2006), s. 100-106 ISSN 1387-1811 R&D Projects: GA AV ČR(CZ) IAA4072404 Institutional research plan: CEZ:AV0Z40720504 Keywords : chromatography * diffusion * mass transfer Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 2.796, year: 2006

  14. Single-Molecule Fluorescence Microscopy Reveals Local Diffusion Coefficients in the Pore Network of an Individual Catalyst Particle

    NARCIS (Netherlands)

    Hendriks, Frank|info:eu-repo/dai/nl/412642697; Meirer, Florian; Kubarev, Alexey V.; Ristanovic, Zoran|info:eu-repo/dai/nl/328233005; Roeffaers, Maarten B J; Vogt, Eelco T. C.|info:eu-repo/dai/nl/073717398; Bruijnincx, Pieter C. A.|info:eu-repo/dai/nl/33799529X; Weckhuysen, Bert M.|info:eu-repo/dai/nl/285484397

    2017-01-01

    We used single-molecule fluorescence microscopy to study self-diffusion of a feedstock-like probe molecule with nanometer accuracy in the macropores of a micrometer-sized, real-life fluid catalytic cracking (FCC) particle. Movies of single fluorescent molecules allowed their movement through the

  15. A convenient method for calculation of ionic diffusion coefficients for accurate selected ion flow tube mass spectrometry, SIFT-MS

    Czech Academy of Sciences Publication Activity Database

    Dryahina, Kseniya; Španěl, Patrik

    2005-01-01

    Roč. 244, 2-3 (2005), s. 148-154 ISSN 1387-3806 R&D Projects: GA ČR GA202/03/0827; GA AV ČR KSK4040110 Institutional research plan: CEZ:AV0Z40400503 Keywords : mobility * diffusion * SIFT-MS * ion geometry * interaction potential Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 2.090, year: 2005

  16. Determination and modelling of osmotic coefficients and vapour pressures of binary systems 1- and 2-propanol with CnMimNTf2 ionic liquids (n = 2, 3, and 4) at T = 323.15 K

    International Nuclear Information System (INIS)

    Calvar, Noelia; Gomez, Elena; Dominguez, Angeles; Macedo, Eugenia A.

    2011-01-01

    Highlights: → Osmotic coefficients of 1- and 2-propanol with C n MimNTf 2 (n = 2, 3, and 4) are determined. → Experimental data were correlated with extended Pitzer model of Archer and MNRTL. → Mean molal activity coefficients and excess Gibbs free energies were calculated. → Effect of the anion is studied comparing these results with literature. - Abstract: The osmotic and activity coefficients and vapour pressures of binary mixtures containing 1-propanol, or 2-propanol and imidazolium-based ionic liquids with bis(trifluoromethylsulfonyl)imide as anion (1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide, C 2 MimNTf 2 , 1-methyl-3-propylimidazolium bis(trifluoromethylsulfonyl)imide, C 3 MimNTf 2 , and 1-butyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide, C 4 MimNTf 2 ) were determined at T = 323.15 K using the vapour pressure osmometry technique. The experimental osmotic coefficients were correlated using the extended Pitzer model modified by Archer and the MNRTL model, obtaining standard deviations lower than 0.033 and 0.064, respectively. The mean molal activity coefficients and the excess Gibbs free energy for the mixtures studied were calculated from the parameters of the extended Pitzer model modified by Archer. Besides the effect of the alkyl-chain of the cation, the effect of the anion can be assessed comparing the experimental results with those previously obtained for imidazolium ionic liquids with sulphate anions.

  17. Spatial characterization of T1 and T2 relaxation times and the water apparent diffusion coefficient in rabbit Achilles tendon subjected to tensile loading.

    Science.gov (United States)

    Wellen, J; Helmer, K G; Grigg, P; Sotak, C H

    2005-03-01

    Tendons exhibit viscoelastic mechanical behavior under tensile loading. The elasticity arises from the collagen chains that form fibrils, while the viscous response arises from the interaction of the water with the solid matrix. Therefore, an understanding of the behavior of water in response to the application of a load is crucial to the understanding of the origin of the viscous response. Three-dimensional MRI mapping of rabbit Achilles tendons was performed at 2.0 T to characterize the response of T(1) and T(2) relaxation times and the apparent diffusion coefficient (ADC) of water to tensile loading. The ADC was measured in directions both parallel (ADC( parallel)) and perpendicular (ADC( perpendicular)) to the long axis of the tendon. At a short diffusion time (5.8 ms) MR parameter maps showed the existence of two regions, here termed "core" and "rim", that exhibited statistically significant differences in T(1), T(2), and ADC( perpendicular) under the baseline loading condition. MR parameter maps were also generated at a second loading condition of approximately 1 MPa. At a diffusion time of 5.8 ms, there was a statistically significant increase in the rim region for both ADC( perpendicular) (57.5%) and ADC( parallel) (20.5%) upon tensile loading. The changes in core ADC(( perpendicular), ( parallel)), as well as the relaxation parameters in both core and rim regions, were not statistically significant. The effect of diffusion time on the ADC(( perpendicular), ( parallel)) values was investigated by creating maps at three additional diffusion times (50.0, 125.0, 250.0 ms) using a diffusion-weighted, stimulated-echo (DW-STE) pulse sequence. At longer diffusion times, ADC(( perpendicular), ( parallel)) values increased rather than approaching a constant value. This observation was attributed to T(1) spin-editing during the DW-STE pulse sequence, which resulted in the loss of short-T(1) components (with correspondingly lower ADCs) at longer diffusion times

  18. Trapping-to-percolation transition in the hopping diffusion of substitutionally disordered solids with a binary energy distribution

    International Nuclear Information System (INIS)

    Parris, P.E.; Bookout, B.D.

    1993-01-01

    We consider charge carriers that undergo nearest-neighbor hopping among the sites of a binary random lattice, each site of which is associated with one of two possible energies E 1 or E 2 . A general and recently observed feature of this problem not predicted by previous treatments of disordered hopping models is a crossover between trap-limited conduction and percolation. We introduce new energy-projected equations of motion whose solutions reveal the deep conductivity minimum associated with this phenomenon, and compare the results predicted to numerical simulations

  19. Viscosity Coefficients of KCl, NaCl, NaI, KNO3, LiNO3, NaBPh4 and Bu4NI in Water - Dimethyl Sulfoxide Binary Mixtures With a Low Organic Solvent Content

    Directory of Open Access Journals (Sweden)

    Adam Bald

    2016-09-01

    Full Text Available In this work the viscosities of KCl, NaCl, NaI, KNO3, LiNO3, NaBPh4 and Bu4NI solutions (from ~0.01 mol dm–3 to ~0.05 mol dm–3 in water (1 + dimethyl sulfoxide (DMSO (2 binary mixtures with mole fractions of DMSO, x2 = 0.01, 0.02, 0.05, 0.075, 0.10 and 0.15, were determined at 298. 15 K. The viscosities measured were used to evaluate the viscosity B-coefficients by means of Jones-Dole's equation. The results obtained allowed us to determine the values of B± coefficients for individual ions using the assumption about the equality B(Bu4N+ = B(BPh4–. All the results have been discussed in terms of ion-solvent interactions.

  20. Reproducibility and changes in the apparent diffusion coefficients of solid tumours treated with combretastatin A4 phosphate and bevacizumab in a two-centre phase I clinical trial

    International Nuclear Information System (INIS)

    Koh, Dow-Mu; Blackledge, Matthew; Collins, David J.; Padhani, Anwar R.; Taylor, N.J.; Stirling, J.J.; Wallace, Toni; Wilton, Benjamin; Leach, Martin O.; Sinha, Rajesh; Judson, Ian; Walicke, Pat; Nathan, Paul

    2009-01-01

    The purpose was to determine the reproducibility of apparent diffusion coefficient (ADC) measurements in a two-centre phase I clinical trial; and to track ADC changes in response to the sequential administration of the vascular disrupting agent, combretastatin A4 phosphate (CA4P), and the anti-angiogenic drug, bevacizumab. Sixteen patients with solid tumours received CA4P and bevacizumab treatment. Echo-planar diffusion-weighted MRI was performed using six b values (b = 0-750 s/mm 2 ) before (x 2), and at 3 and 72 h after a first dose of CA4P. Bevacizumab was given 4 h after a second dose of CA4P, and imaging performed 3 h post CA4P and 72 h after bevacizumab treatment. The coefficient of repeatability (r) of ADC total (all b values), ADC high (b = 100-750) and ADC low (b = 0-100) was calculated by Bland-Altman analysis. The ADC total and ADC high showed good measurement reproducibility (r% = 13.3, 14.1). There was poor reproducibility of the perfusion-sensitive ADC low (r% = 62.5). Significant increases in the median ADC total and ADC high occurred at 3 h after the second dose of CA4P (p < 0.05). ADC measurements were highly reproducible in a two-centre clinical trial setting and appear promising for evaluating the effects of drugs that target tumour vasculature. (orig.)

  1. Reproducibility and changes in the apparent diffusion coefficients of solid tumours treated with combretastatin A4 phosphate and bevacizumab in a two-centre phase I clinical trial

    Energy Technology Data Exchange (ETDEWEB)

    Koh, Dow-Mu; Blackledge, Matthew; Collins, David J. [Royal Marsden Hospital, Department of Radiology, Sutton (United Kingdom); Institute of Cancer Research, Cancer Research UK Clinical Magnetic Resonance Research Group, Sutton (United Kingdom); Padhani, Anwar R.; Taylor, N.J.; Stirling, J.J. [Mount Vernon Hospital, Paul Strickland Scanner Centre, Middlesex (United Kingdom); Wallace, Toni [Royal Marsden Hospital, Department of Radiology, Sutton (United Kingdom); Wilton, Benjamin; Leach, Martin O. [Institute of Cancer Research, Cancer Research UK Clinical Magnetic Resonance Research Group, Sutton (United Kingdom); Sinha, Rajesh; Judson, Ian [Royal Marsden Hospital, Phase I Clinical Unit, Sutton (United Kingdom); Walicke, Pat [Oxigene Inc, Waltham, MA (United States); Nathan, Paul [Mount Vernon Hospital, Department of Medical Oncology, Middlesex (United Kingdom)

    2009-11-15

    The purpose was to determine the reproducibility of apparent diffusion coefficient (ADC) measurements in a two-centre phase I clinical trial; and to track ADC changes in response to the sequential administration of the vascular disrupting agent, combretastatin A4 phosphate (CA4P), and the anti-angiogenic drug, bevacizumab. Sixteen patients with solid tumours received CA4P and bevacizumab treatment. Echo-planar diffusion-weighted MRI was performed using six b values (b = 0-750 s/mm{sup 2}) before (x 2), and at 3 and 72 h after a first dose of CA4P. Bevacizumab was given 4 h after a second dose of CA4P, and imaging performed 3 h post CA4P and 72 h after bevacizumab treatment. The coefficient of repeatability (r) of ADC total (all b values), ADC high (b = 100-750) and ADC low (b = 0-100) was calculated by Bland-Altman analysis. The ADC total and ADC high showed good measurement reproducibility (r% = 13.3, 14.1). There was poor reproducibility of the perfusion-sensitive ADC low (r% = 62.5). Significant increases in the median ADC total and ADC high occurred at 3 h after the second dose of CA4P (p < 0.05). ADC measurements were highly reproducible in a two-centre clinical trial setting and appear promising for evaluating the effects of drugs that target tumour vasculature. (orig.)

  2. Disorder effect on heat capacity, self-diffusion coefficient, and choosing best potential model for melting temperature, in gold–copper bimetallic nanocluster with 55 atoms

    International Nuclear Information System (INIS)

    Taherkhani, Farid; Akbarzadeh, Hamed; Feyzi, Mostafa; Rafiee, Hamid Reza

    2015-01-01

    Molecular dynamics simulation has been implemented for doping effect on melting temperature, heat capacity, self-diffusion coefficient of gold–copper bimetallic nanostructure with 55 total gold and copper atom numbers and its bulk alloy. Trend of melting temperature for gold–copper bimetallic nanocluster is not same as melting temperature copper–gold bulk alloy. Molecular dynamics simulation of our result regarding bulk melting temperature is consistence with available experimental data. Molecular dynamics simulation shows that melting temperature of gold–copper bimetallic nanocluster increases with copper atom fraction. Semi-empirical potential model and quantum Sutton–Chen potential models do not change melting temperature trend with copper doping of gold–copper bimetallic nanocluster. Self-diffusion coefficient of copper atom is greater than gold atom in gold–copper bimetallic nanocluster. Semi-empirical potential within the tight-binding second moment approximation as new application potential model for melting temperature of gold–copper bulk structure shows better result in comparison with EAM, Sutton–Chen potential, and quantum Sutton–Chen potential models

  3. Contribution to the benchmark for ternary mixtures: Measurement of diffusion and Soret coefficients of ternary system tetrahydronaphtalene-isobutylbenzene-n-dodecane with mass fractions 80-10-10 at 25 °C.

    Science.gov (United States)

    Galand, Quentin; Van Vaerenbergh, Stéfan

    2015-04-01

    This paper provides the molecular diffusion and Soret coefficients of the ternary system 1,2,3,4-tetrahydronaphtalene, isobutylbenzene, n -dodecane system at mass fractions 0.8-0.1-0.1 and temperature 25 (°)C for implementation into the benchmark presented in this topical issue. The Soret coefficients are determined by digital interferometry using the data of DSC-DCMIX microgravity experiment. The method used takes into account the influence of the thermal field on the Soret separations and the selection of the image processing techniques results in reproducible Soret coefficients.The diffusion coefficients are obtained by the Open Ended Capillary technique The fitting of the data collected through a set of two complementary experimental runs allows retrieving the four Fickian diffusion coefficients.

  4. Preliminary quantification of the permeability, solubility and diffusion coefficients of major aroma compounds present in herbs through various plastic packaging materials.

    Science.gov (United States)

    Leelaphiwat, Pattarin; Auras, Rafael A; Burgess, Gary J; Harte, Janice B; Chonhenchob, Vanee

    2018-03-01

    Aroma permeation through packaging material is an important factor when designing a package for food products. The masses of aroma compounds permeating through films over time were measured at 25 °C using a quasi-isostatic system. A model was proposed for estimating the permeability coefficients (P) of key aroma compounds present in fresh herbs (i.e. eucalyptol, estragole, linalool and citral) through major plastic films used by the food industry [i.e. low-density polyethylene (LDPE), polypropylene (PP), nylon (Nylon), polyethylene terephthalate (PET), metalised-polyethylene terephthalate (MPET) and poly(lactic acid) (PLA)]. Solubility coefficients (S) were estimated from the amount of aroma compound sorbed in the films. Diffusion coefficients (D) were estimated following from the relation P = D*S. P and D for all four aroma compounds were highest in LDPE, except for eucalyptol, which P was slightly higher in PLA. The solubility coefficients and contact angles were highest in PLA suggesting the highest affinity of PLA to these aroma compounds. The theoretical solubility parameters were correlated with the solubility coefficients for estragole and citral, but not for eucalyptol and linalool. The preliminary P, D and S of eucalyptol, estragole, linalool and citral through LDPE, PP, Nylon, PET, MPET and PLA can be useful in selecting the proper packaging material for preserving these specific aroma compounds in food products and can potentially be used for estimating the shelf life of food products based on aroma loss. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  5. The Trouble with Diffusion

    Directory of Open Access Journals (Sweden)

    R.T. DeHoff

    2002-09-01

    Full Text Available The phenomenological formalism, which yields Fick's Laws for diffusion in single phase multicomponent systems, is widely accepted as the basis for the mathematical description of diffusion. This paper focuses on problems associated with this formalism. This mode of description of the process is cumbersome, defining as it does matrices of interdiffusion coefficients (the central material properties that require a large experimental investment for their evaluation in three component systems, and, indeed cannot be evaluated for systems with more than three components. It is also argued that the physical meaning of the numerical values of these properties with respect to the atom motions in the system remains unknown. The attempt to understand the physical content of the diffusion coefficients in the phenomenological formalism has been the central fundamental problem in the theory of diffusion in crystalline alloys. The observation by Kirkendall that the crystal lattice moves during diffusion led Darken to develop the concept of intrinsic diffusion, i.e., atom motion relative to the crystal lattice. Darken and his successors sought to relate the diffusion coefficients computed for intrinsic fluxes to those obtained from the motion of radioactive tracers in chemically homogeneous samples which directly report the jump frequencies of the atoms as a function of composition and temperature. This theoretical connection between tracer, intrinsic and interdiffusion behavior would provide the basis for understanding the physical content of interdiffusion coefficients. Definitive tests of the resulting theoretical connection have been carried out for a number of binary systems for which all three kinds of observations are available. In a number of systems predictions of intrinsic coefficients from tracer data do not agree with measured values although predictions of interdiffusion coefficients appear to give reasonable agreement. Thus, the complete

  6. Apparent diffusion coefficient quantification as an early imaging biomarker of response and predictor of survival following yttrium-90 radioembolization for unresectable infiltrative hepatocellular carcinoma with portal vein thrombosis.

    Science.gov (United States)

    Kokabi, Nima; Camacho, Juan C; Xing, Minzhi; Qiu, Deqiang; Kitajima, Hiroumi; Mittal, Pardeep K; Kim, Hyun S

    2014-10-01

    To investigate early diffusion-weighted imaging (DWI) at 30-days post-yttrium-90 (Y-90) radioembolization as a predictor of treatment response and survival in unresectable infiltrative hepatocellular carcinoma (HCC) with portal vein thrombosis (PVT). In a prospective study, 18 consecutive patients with unresectable infiltrative HCC and PVT underwent Y-90 therapy. MR imaging was obtained pre Y-90, and at 1 and 3 months post-therapy with DWI fat-suppressed tri-directional diffusion gradient (b = 50, 400, 800 s/mm(2)). Response was evaluated using target mRECIST and EASL. Relative change in apparent diffusion coefficient (ADC) value of tumors was evaluated. Statistical analysis using receiver operator characteristic curves was performed. Paired t test and Pearson correlation coefficient (r) were used to assess intra- and inter-observer variability. Survival analysis was performed using Kaplan-Meier estimation and log-rank test. Mean ADC values of all HCC's at baseline and at 30-days post-Y90 therapy was 0.86 × 10(-3) and 1.17×10(-3) mm(2)/s, respectively (p 30% increase in ADC value at 30-days was found to be at least 90% sensitive in predicting response at 90 days. A >30% increase in ADC value at 30-days predicted significantly prolonged survival. A 30% increase in ADC value at 30-days measured post Y90 is a reproducible early imaging response biomarker predicting tumor response and prolonged survival following Y-90 therapy in infiltrative HCC with PVT.

  7. Apparent diffusion coefficient measurements of bilateral kidneys at 3 T MRI: Effects of age, gender, and laterality in healthy adults

    International Nuclear Information System (INIS)

    Suo, S.-T.; Cao, M.-Q.; Ding, Y.-Z.; Yao, Q.-Y.; Wu, G.-Y.; Xu, J.-R.

    2014-01-01

    Aim: To investigate the effects of age and gender on apparent diffusion coefficient (ADC) measurements of bilateral kidneys at 3 T MRI, and compare the ADC values of left and right kidneys. Materials and methods: In all, 137 healthy participants (mean age 42.8 ± 14.7 years; age range 16–75 years) comprising 68 male and 69 female participants were enrolled. Three Tesla echo-planar diffusion-weighted imaging (DWI) of bilateral kidneys was performed and ADC values were measured in the cortex, medulla, and whole parenchyma. Pearson correlation analysis and linear regression were performed to determine the associations between the ADC values in each region and age. Effects of age and gender on ADC values were analysed using two-factor analysis of variance (ANOVA). The paired-samples t-test was established to compare the ADC values between left and right kidneys. Results: ADC values were significantly higher in the young group (≤50 years) than in the old group (>50 years), and correlated inversely with the age in all regions. Male participants had higher ADC values than female participants in all regions except left medulla. Two-factor ANOVA of age × gender showed no significant interactions between the variables age and gender were found. No significant differences in ADC values between left and right kidneys were observed. Conclusion: Renal ADC values are age- and gender-dependent, and show no significant difference between left and right kidneys. Age- and gender-related effects should be taken into consideration in future renal DWI studies when using normal ADC values from health controls. - Highlights: • Renal apparent diffusion coefficient (ADC) values decrease with ageing. • Men tend to have higher renal ADC values than women. • Bilateral kidneys seem to have no significantly different ADC values

  8. Amide proton transfer imaging to discriminate between low- and high-grade gliomas: added value to apparent diffusion coefficient and relative cerebral blood volume

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Yoon Seong; Ahn, Sung Soo; Lee, Seung-Koo [Yonsei University College of Medicine, Department of Radiology and Research Institute of Radiological Science, College of Medicine, Seoul (Korea, Republic of); Chang, Jong Hee; Kang, Seok-Gu [Yonsei University College of Medicine, Department of Neurosurgery, Seoul (Korea, Republic of); Kim, Se Hoon [Yonsei University College of Medicine, Department of Pathology, Seoul (Korea, Republic of); Zhou, Jinyuan [Johns Hopkins University School of Medicine, Division of MRI Research, Department of Radiology, Baltimore, MD (United States)

    2017-08-15

    To evaluate the added value of amide proton transfer (APT) imaging to the apparent diffusion coefficient (ADC) from diffusion tensor imaging (DTI) and the relative cerebral blood volume (rCBV) from perfusion magnetic resonance imaging (MRI) for discriminating between high- and low-grade gliomas. Forty-six consecutive adult patients with diffuse gliomas who underwent preoperative APT imaging, DTI and perfusion MRI were enrolled. APT signals were compared according to the World Health Organization grade. The diagnostic ability and added value of the APT signal to the ADC and rCBV for discriminating between low- and high-grade gliomas were evaluated using receiver operating characteristic (ROC) analyses and integrated discrimination improvement. The APT signal increased as the glioma grade increased. The discrimination abilities of the APT, ADC and rCBV values were not significantly different. Using both the APT signal and ADC significantly improved discrimination vs. the ADC alone (area under the ROC curve [AUC], 0.888 vs. 0.910; P = 0.007), whereas using both the APT signal and rCBV did not improve discrimination vs. the rCBV alone (AUC, 0.927 vs. 0.923; P = 0.222). APT imaging may be a useful imaging biomarker that adds value to the ADC for discriminating between low- and high-grade gliomas. (orig.)

  9. Amide proton transfer imaging to discriminate between low- and high-grade gliomas: added value to apparent diffusion coefficient and relative cerebral blood volume

    International Nuclear Information System (INIS)

    Choi, Yoon Seong; Ahn, Sung Soo; Lee, Seung-Koo; Chang, Jong Hee; Kang, Seok-Gu; Kim, Se Hoon; Zhou, Jinyuan

    2017-01-01

    To evaluate the added value of amide proton transfer (APT) imaging to the apparent diffusion coefficient (ADC) from diffusion tensor imaging (DTI) and the relative cerebral blood volume (rCBV) from perfusion magnetic resonance imaging (MRI) for discriminating between high- and low-grade gliomas. Forty-six consecutive adult patients with diffuse gliomas who underwent preoperative APT imaging, DTI and perfusion MRI were enrolled. APT signals were compared according to the World Health Organization grade. The diagnostic ability and added value of the APT signal to the ADC and rCBV for discriminating between low- and high-grade gliomas were evaluated using receiver operating characteristic (ROC) analyses and integrated discrimination improvement. The APT signal increased as the glioma grade increased. The discrimination abilities of the APT, ADC and rCBV values were not significantly different. Using both the APT signal and ADC significantly improved discrimination vs. the ADC alone (area under the ROC curve [AUC], 0.888 vs. 0.910; P = 0.007), whereas using both the APT signal and rCBV did not improve discrimination vs. the rCBV alone (AUC, 0.927 vs. 0.923; P = 0.222). APT imaging may be a useful imaging biomarker that adds value to the ADC for discriminating between low- and high-grade gliomas. (orig.)

  10. Evolution of Apparent Diffusion Coefficient and Fractional Anisotropy in the Cerebrum of Asphyxiated Newborns Treated with Hypothermia over the First Month of Life

    Directory of Open Access Journals (Sweden)

    Saskia Kwan

    2015-01-01

    Full Text Available The objective of this study was to assess the evolution of diffusion-weighted imaging (DWI and diffusion-tensor imaging (DTI over the first month of life in asphyxiated newborns treated with hypothermia and to compare it with that of healthy newborns. Asphyxiated newborns treated with hypothermia were enrolled prospectively; and the presence and extent of brain injury were scored on each MRI. Apparent diffusion coefficient (ADC and fractional anisotropy (FA values were measured in the basal ganglia, in the white matter and in the cortical grey matter. Sixty-one asphyxiated newborns treated with hypothermia had a total of 126 ADC and FA maps. Asphyxiated newborns developing brain injury eventually had significantly decreased ADC values on days 2-3 of life and decreased FA values around day 10 and 1 month of life compared with those not developing brain injury. Despite hypothermia treatment, asphyxiated newborns may develop brain injury that still can be detected with advanced neuroimaging techniques such as DWI and DTI as early as days 2-3 of life. A study of ADC and FA values over time may aid in the understanding of how brain injury develops in these newborns despite hypothermia treatment.

  11. Diffuse interstellar bands of unprecedented strength in the line of sight towards high-mass X-ray binary

    NARCIS (Netherlands)

    Cox, N.L.J.; Kaper, L.; Foing, B.H.; Ehrenfreund, P.

    2005-01-01

    High-resolution VLT/UVES spectra of the strongly reddened O supergiant companion to the X-ray pulsar 4U 1907+09 provide a unique opportunity to study the nature of the diffuse interstellar bands (DIBs) at unprecedented strength. We detect about 180 known DIBs, of which about 25

  12. Double diffusive unsteady convective micropolar flow past a vertical porous plate moving through binary mixture using modified Boussinesq approximation

    Directory of Open Access Journals (Sweden)

    Isaac Lare Animasaun

    2016-06-01

    Full Text Available The problem of unsteady convective with thermophoresis, chemical reaction and radiative heat transfer in a micropolar fluid flow past a vertical porous surface moving through binary mixture considering temperature dependent dynamic viscosity and constant vortex viscosity has been investigated theoretically. For proper and correct analysis of fluid flow along vertical surface with a temperature lesser than that of the free stream, Boussinesq approximation and temperature dependent viscosity model were modified and incorporated into the governing equations. The governing equations are converted to systems of ordinary differential equations by applying suitable similarity transformations and solved numerically using fourth-order Runge–Kutta method along with shooting technique. The results of the numerical solution are presented graphically and in tabular forms for different values of parameters. Velocity profile increases with temperature dependent variable fluid viscosity parameter. Increase of suction parameter corresponds to an increase in both temperature and concentration within the thin boundary layer.

  13. The Effect of Temperature on Kinetics and Diffusion Coefficients of Metallocene Derivatives in Polyol-Based Deep Eutectic Solvents.

    Directory of Open Access Journals (Sweden)

    Laleh Bahadori

    Full Text Available The temperature dependence of the density, dynamic viscosity and ionic conductivity of several deep eutectic solvents (DESs containing ammonium-based salts and hydrogen bond donvnors (polyol type are investigated. The temperature-dependent electrolyte viscosity as a function of molar conductivity is correlated by means of Walden's rule. The oxidation of ferrocene (Fc/Fc+ and reduction of cobaltocenium (Cc+/Cc at different temperatures are studied by cyclic voltammetry and potential-step chronoamperometry in DESs. For most DESs, chronoamperometric transients are demonstrated to fit an Arrhenius-type relation to give activation energies for the diffusion of redox couples at different temperatures. The temperature dependence of the measured conductivities of DES1 and DES2 are better correlated with the Vogel-Tamman-Fulcher equation. The kinetics of the Fc/Fc+ and Cc+/Cc electrochemical systems have been investigated over a temperature range from 298 to 338 K. The heterogeneous electron transfer rate constant is then calculated at different temperatures by means of a logarithmic analysis. The glycerol-based DES (DES5 appears suitable for further testing in electrochemical energy storage devices.

  14. The Effect of Temperature on Kinetics and Diffusion Coefficients of Metallocene Derivatives in Polyol-Based Deep Eutectic Solvents.

    Science.gov (United States)

    Bahadori, Laleh; Chakrabarti, Mohammed Harun; Manan, Ninie Suhana Abdul; Hashim, Mohd Ali; Mjalli, Farouq Sabri; AlNashef, Inas Muen; Brandon, Nigel

    2015-01-01

    The temperature dependence of the density, dynamic viscosity and ionic conductivity of several deep eutectic solvents (DESs) containing ammonium-based salts and hydrogen bond donvnors (polyol type) are investigated. The temperature-dependent electrolyte viscosity as a function of molar conductivity is correlated by means of Walden's rule. The oxidation of ferrocene (Fc/Fc+) and reduction of cobaltocenium (Cc+/Cc) at different temperatures are studied by cyclic voltammetry and potential-step chronoamperometry in DESs. For most DESs, chronoamperometric transients are demonstrated to fit an Arrhenius-type relation to give activation energies for the diffusion of redox couples at different temperatures. The temperature dependence of the measured conductivities of DES1 and DES2 are better correlated with the Vogel-Tamman-Fulcher equation. The kinetics of the Fc/Fc+ and Cc+/Cc electrochemical systems have been investigated over a temperature range from 298 to 338 K. The heterogeneous electron transfer rate constant is then calculated at different temperatures by means of a logarithmic analysis. The glycerol-based DES (DES5) appears suitable for further testing in electrochemical energy storage devices.

  15. Value of apparent diffusion coefficient calculation before and after gustatory stimulation in the diagnosis of acute or chronic parotitis

    Energy Technology Data Exchange (ETDEWEB)

    Ries, T.; Arndt, C.; Regier, M.; Cramer, M.C.; Adam, G.; Habermann, C.R. [Diagnostic Center, Department of Diagnostic and Interventional Radiology, Hamburg (Germany); Graessner, J. [Medical Solutions Hamburg, Siemens AG, Hamburg (Germany); Reitmeier, F.; Jaehne, M. [University Medical Center Hamburg-Eppendorf, Center of Head Care and Dermatology, Department of Otorhinolaryngology, Hamburg (Germany)

    2008-10-15

    The purpose of the study was to investigate the value of diffusion-weighted (DW) echo-planar imaging (EPI) for quantifying physiological changes of the parotid gland before and after gustatory stimulation in patients suffering from acute or chronic recurrent inflammation in comparison with healthy volunteers. Using a DW-EPI sequence at 1.5 T, parotid glands of 19 consecutive patients with acute (n = 14) and chronic (n=) inflammation of parotid glands and 52 healthy volunteers were examined. Magnetic-resonance (MR) images were obtained before and after gustatory stimulation with 5 cc of lemon juice. In volunteers mean ADC values of 1.14 x 10{sup -3} mm{sup 2}/s before and 1.2 x 10{sup -3} mm{sup 2}/s after gustatory stimulation were observed. In acute inflammation ADC values were higher before [1.22 x 10{sup -3} mm{sup 2}/s (p = 0.006)] and after stimulation [1.32 x 10{sup -3} mm{sup 2}/s (p<0.001)]. Before stimulation ADC differences between chronic inflammation (1.05 x 10{sup -3} mm{sup 2}/s) and healthy volunteers (p = 0.04) as well as between acute and chronic inflammation (p=0.005) were statistically significant. No differences were detected after stimulation between chronic inflammation (1.2 x 10{sup -3} mm{sup 2}/s) and healthy volunteers (p=0.94) and between acute and chronic inflammation (p=0.15), respectively. DW-EPI seems to display the physiological changes of the parotid gland in patients suffering from acute or chronic inflammation and might be useful for discriminating healthy from affected glands. (orig.)

  16. Diffusion simulation of ferric ions in dosemeter Fricke-gel with variable diffusion coefficient; Simulacao da difusao de ions ferricos em dosimetros Fricke-gel com coeficiente de difusao variavel

    Energy Technology Data Exchange (ETDEWEB)

    Milani, Caio Jacob; Bevilacqua, Joyce da Silva, E-mail: caio.milani@usp.br, E-mail: joyce@ime.usp.br [Universidade de Sao Paulo (USP), Sao Paulo, SP (Brazil). Inst. de Matematica e Estatistica. Dept. de Matematica Aplicada; Rodrigues Junior, Orlando, E-mail: rodrijr@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil). Gerencia de Metrologia das Radiacoes

    2014-07-01

    Dosimetry using dosimeters Fricke-xylenol-Gel (FXG) allows confirmation and better understanding of radiotherapy treatments. The technique involves the evaluation of volumes irradiated by magnetic resonance imaging (MRI) or CT-optical. In both cases, the time spent between the irradiation and measurement is an important factor that directly influences the results. The quality of the images can be compromised by the mobility of ferric ions (Fe 3+), formed during the interaction of radiation with matter, increasing the uncertainty in determining the isodose. In this work, we simulated the dynamic involving ferric ions formed in one irradiated region irradiated in a two-dimensional domain with a variable diffusion coefficient. This phenomenon is modeled by a differential equation and solved numerically by an efficient algorithm that generalizes the Crank-Nicolson method. The stability and consistency of the method guarantee the convergence of the numerical solution for a predefined tolerance based in the choice of discretization steps of time and space. Different continuous functions were chosen to represent the diffusion coefficient and graphical views of the phenomenon are presented for a better understanding of the process.

  17. Correlation between electrical conductivity and apparent diffusion coefficient in breast cancer: effect of necrosis on magnetic resonance imaging.

    Science.gov (United States)

    Kim, Soo-Yeon; Shin, Jaewook; Kim, Dong-Hyun; Kim, Eun-Kyung; Moon, Hee Jung; Yoon, Jung Hyun; You, Jai Kyung; Kim, Min Jung

    2018-03-06

    To investigate the correlation between conductivity and ADC in invasive ductal carcinoma according to the presence of necrosis on MRI. Eighty-one women with invasive ductal carcinoma ≥1 cm on T2-weighted fast spin echo sequence of preoperative MRI were included. Phase-based MR electric properties tomography was used to reconstruct conductivity. Mean ADC was measured. Necrosis was defined as an area with very high T2 signal intensity. The relationship between conductivity and ADC was examined using Spearman's correlation coefficient (r). Multiple linear regression analysis was performed to identify factors associated with conductivity or ADC. In the total group, conductivity showed negative correlation with ADC (r = -0.357, p = 0.001). This correlation was maintained in the subgroup without necrosis (n = 53, r = -0.455, p = 0.001), but not in the subgroup with necrosis (n = 28, r = -0.080, p = 0.687). The correlation between the two parameters was different according to necrosis (r = -0.455 vs -0.080, p = 0.047). HER2 enriched subtype was independently associated with conductivity (p = 0.029). Necrosis on MRI was independently associated with ADC (p = 0.027). Conductivity shows negative correlation with ADC that is abolished by the presence of necrosis on MRI. • Electric conductivity showed negative correlation with ADC • However, the correlation was abolished by the presence of necrosis on MRI • HER2-enriched subtype was independently associated with conductivity • Necrosis on MRI was independently associated with ADC.

  18. Studies of atomic diffusion in binary alloys by X-ray photon correlation spectroscopy with particular attention to B2 phases

    International Nuclear Information System (INIS)

    Stana, M.B.

    2015-01-01

    The way single atoms change places in a condensed system determines many of its properties. Insight into the mechanisms controlling such processes, therefore, yields a better understanding of matter which in turn allows for improving fabrication and tailoring of material properties. Intermetallic alloys have many attractive features for industrial applications, such as high specific strength, good corrosion and oxidation resistance and low raw material cost. Their application is, however, still strongly limited by properties such as high brittleness at low temperatures. Methods capable of studying diffusion on an atomistic level have been restricted to high temperatures close to the melting point of intermetallics until now. The new method of atomic- scale X-ray Photon Correlation Spectroscopy provides a means of studying these materials at technically relevant working temperatures. This thesis demonstrates the application of this new technique to binary intermetallic alloys. In the first part the theoretical concepts underlying atomic-scale X-ray Photon Correlation Spectroscopy such as correlation, rate equations, scattering and reciprocal space will be tho- roughly discussed. As computer simulation techn