WorldWideScience

Sample records for bilateral digit measurements

  1. Does crossover innervation really affect the clinical outcome? A comparison of outcome between unilateral and bilateral digital nerve repair

    Directory of Open Access Journals (Sweden)

    Melike Oruç

    2016-01-01

    Full Text Available Digital nerve injuries are the mostly detected nerve injury in the upper extremity. However, since the clinical phenomenon of crossover innervation at some degree from uninjured digital nerve to the injured side occurs after digital nerve injuries is sustained, one could argue that this concept might even result in the overestimation of the outcome of the digital nerve repair. With this knowledge in mind, this study aimed to present novel, pure, focused and valuable clinical data by comparing the outcomes of bilateral and unilateral digital nerve repair. A retrospective review of 28 fingers with unilateral or bilateral digital nerve repair using end-to-end technique in 19 patients within 2 years was performed. Weber′s two-point discrimination, sharp/dull discrimination, warm/cold sensation and Visual Analog Scale scoring were measured at final 12-month follow ups in all patients. There was no significant difference in recovery of sensibility after unilateral and bilateral digital nerve repairs. Though there is crossover innervation microscopically, it is not important in the clinical evaluation period. According to clinical findings from this study, crossover innervations appear to be negligible in the estimation of outcomes of digital neurorrhaphy.

  2. A Digital Image Denoising Algorithm Based on Gaussian Filtering and Bilateral Filtering

    Directory of Open Access Journals (Sweden)

    Piao Weiying

    2018-01-01

    Full Text Available Bilateral filtering has been applied in the area of digital image processing widely, but in the high gradient region of the image, bilateral filtering may generate staircase effect. Bilateral filtering can be regarded as one particular form of local mode filtering, according to above analysis, an mixed image de-noising algorithm is proposed based on Gaussian filter and bilateral filtering. First of all, it uses Gaussian filter to filtrate the noise image and get the reference image, then to take both the reference image and noise image as the input for range kernel function of bilateral filter. The reference image can provide the image’s low frequency information, and noise image can provide image’s high frequency information. Through the competitive experiment on both the method in this paper and traditional bilateral filtering, the experimental result showed that the mixed de-noising algorithm can effectively overcome staircase effect, and the filtrated image was more smooth, its textural features was also more close to the original image, and it can achieve higher PSNR value, but the amount of calculation of above two algorithms are basically the same.

  3. Multiscale bilateral filtering for improving image quality in digital breast tomosynthesis

    Science.gov (United States)

    Lu, Yao; Chan, Heang-Ping; Wei, Jun; Hadjiiski, Lubomir M.; Samala, Ravi K.

    2015-01-01

    Purpose: Detection of subtle microcalcifications in digital breast tomosynthesis (DBT) is a challenging task because of the large, noisy DBT volume. It is important to enhance the contrast-to-noise ratio (CNR) of microcalcifications in DBT reconstruction. Most regularization methods depend on local gradient and may treat the ill-defined margins or subtle spiculations of masses and subtle microcalcifications as noise because of their small gradient. The authors developed a new multiscale bilateral filtering (MSBF) regularization method for the simultaneous algebraic reconstruction technique (SART) to improve the CNR of microcalcifications without compromising the quality of masses. Methods: The MSBF exploits a multiscale structure of DBT images to suppress noise and selectively enhance high frequency structures. At the end of each SART iteration, every DBT slice is decomposed into several frequency bands via Laplacian pyramid decomposition. No regularization is applied to the low frequency bands so that subtle edges of masses and structured background are preserved. Bilateral filtering is applied to the high frequency bands to enhance microcalcifications while suppressing noise. The regularized DBT images are used for updating in the next SART iteration. The new MSBF method was compared with the nonconvex total p-variation (TpV) method for noise regularization with SART. A GE GEN2 prototype DBT system was used for acquisition of projections at 21 angles in 3° increments over a ±30° range. The reconstruction image quality with no regularization (NR) and that with the two regularization methods were compared using the DBT scans of a heterogeneous breast phantom and several human subjects with masses and microcalcifications. The CNR and the full width at half maximum (FWHM) of the line profiles of microcalcifications and across the spiculations within their in-focus DBT slices were used as image quality measures. Results: The MSBF method reduced contouring artifacts

  4. Bilateral Comparison CIEMAT-CENTIS-DMR for radionuclide activity measurements

    International Nuclear Information System (INIS)

    Oropesa Verdecia, P.; Garcia-Torano, E.

    2004-01-01

    We present the results of a bilateral comparison of radionuclide activity measurements between the Radionuclide Metrology Department of the Center of Isotopes of Cuba (CENTIS-DMR), and the Ionising Radiation Metrology Laboratory (LMRI) of the Centro de Investigaciones Energeticas, Medioambientales y Tecnologicas (CIEMAT) of Spain. The aim of the comparison was to establish the comparability of the measurement instruments and methods used to obtain radioactive reference materials of some gamma-emitting nuclides at CENTIS-DMR. The results revealed that there are no statistically significant differences between the data reported by both laboratories. (Author) 7 refs

  5. General temperature field measurement by digital holography

    Czech Academy of Sciences Publication Activity Database

    Doleček, Roman; Psota, Pavel; Lédl, Vít; Vít, Tomáš; Václavík, Jan; Kopecký, V.

    2013-01-01

    Roč. 52, č. 1 (2013), A319-A325 ISSN 1559-128X Institutional support: RVO:61389021 Keywords : digital holography * temperature field measurement * tomography Subject RIV: BH - Optics, Masers, Lasers Impact factor: 1.649, year: 2013

  6. A novel computed method to reconstruct the bilateral digital interarticular channel of atlas and its use on the anterior upper cervical screw fixation

    Directory of Open Access Journals (Sweden)

    Ai-Min Wu

    2016-02-01

    Full Text Available Purpose. To investigate a novel computed method to reconstruct the bilateral digital interarticular channel of atlas and its potential use on the anterior upper cervical screw fixation. Methods. We have used the reverse engineering software (image-processing software and computer-aided design software to create the approximate and optimal digital interarticular channel of atlas for 60 participants. Angles of channels, diameters of inscribed circles, long and short axes of ellipses were measured and recorded, and gender-specific analysis was also performed. Results. The channels provided sufficient space for one or two screws, and the parameters of channels are described. While the channels of females were smaller than that of males, no significant difference of angles between males and females were observed. Conclusion. Our study demonstrates the radiological features of approximate digital interarticular channels, optimal digital interarticular channels of atlas, and provides the reference trajectory of anterior transarticular screws and anterior occiput-to-axis screws. Additionally, we provide a protocol that can help make a pre-operative plan for accurate placement of anterior transarticular screws and anterior occiput-to-axis screws.

  7. Experimental research of digital holographic microscopic measuring

    Science.gov (United States)

    Zhu, Xueliang; Chen, Feifei; Li, Jicheng

    2013-06-01

    Digital holography is a new imaging technique, which is developed on the base of optical holography, Digital processing, and Computer techniques. It is using CCD instead of the conventional silver to record hologram, and then reproducing the 3D contour of the object by the way of computer simulation. Compared with the traditional optical holographic, the whole process is of simple measuring, lower production cost, faster the imaging speed, and with the advantages of non-contact real-time measurement. At present, it can be used in the fields of the morphology detection of tiny objects, micro deformation analysis, and biological cells shape measurement. It is one of the research hot spot at home and abroad. This paper introduced the basic principles and relevant theories about the optical holography and Digital holography, and researched the basic questions which influence the reproduce images in the process of recording and reconstructing of the digital holographic microcopy. In order to get a clear digital hologram, by analyzing the optical system structure, we discussed the recording distance and of the hologram. On the base of the theoretical studies, we established a measurement and analyzed the experimental conditions, then adjusted them to the system. To achieve a precise measurement of tiny object in three-dimension, we measured MEMS micro device for example, and obtained the reproduction three-dimensional contour, realized the three dimensional profile measurement of tiny object. According to the experiment results consider: analysis the reference factors between the zero-order term and a pair of twin-images by the choice of the object light and the reference light and the distance of the recording and reconstructing and the characteristics of reconstruction light on the measurement, the measurement errors were analyzed. The research result shows that the device owns certain reliability.

  8. Bilateral renal cell carcinoma in a horseshoe kidney: preoperative assessment with MRI and digital subtraction angiography

    International Nuclear Information System (INIS)

    Schubert, R.A.; Soeldner, J.; Kaiser, W.A.; Steiner, T.; Schubert, J.

    1998-01-01

    Renal cell carcinoma in a horseshoe kidney is an unusual entity. To our knowledge, only 123 cases have been published to date. We report the first bilateral case of two clear-cell carcinomas in an asymmetrically fused kidney. Optimum preservation of renal function after radical tumor removal requires accurate preoperative imaging. Since the vascular supply in fusion anomalies is extremely variable, angiography is mandatory. Magnetic resonance imaging was most suitable to predict the tumor extent and localization, because it simultaneously gave the most comprehensive anatomical overview of the malformation. (orig.)

  9. Vibration measurements by pulsed digital holographic endoscopy

    Science.gov (United States)

    Schedin, Staffan; Pedrini, Giancarlo; Perez-Lopez, Carlos; Mendoza Santoyo, Fernando

    2005-02-01

    Digital holographic interferometry in combination with a flexible fiber endoscope allows high precision measurements of deformations on hidden objects surfaces, inside cavities and objects with small access apertures. A digital holographic endoscopy system is described with a frequency-doubled, twin oscillator Q-switched pulsed Nd:YAG laser as light source. A sequence of digital hologram pairs are recorded with a maximum repetition rate of 260 ms. Each digital hologram is captured at separate video frames of a CCD-camera. The time separation between the laser pulses from each cavity can be set in the range from 50 to 500 μs. The digital holograms are transferred to a PC via a frame grabber and evaluated quantitatively by the Fourier transform method. The resulting phase fringe pattern has the information needed to evaluate quantitatively the amount of the deformation. Experimental results of vibration measurements of hidden mechanical and biological object surfaces are presented. The quality of the results obtained by mechanical object surfaces is usually higher than for biological surfaces. This can be explained easily by the fact that a biological surface is much more complex than a mechanical surface in the sense that some parts of the surface may reflect the light well whereas other parts may absorb the light. Also, biological surfaces are translucent, which means that part of the light may enter inside the sample where it may be absorbed or reflected.

  10. Single-lens 3D digital image correlation system based on a bilateral telecentric lens and a bi-prism: validation and application.

    Science.gov (United States)

    Wu, Lifu; Zhu, Jianguo; Xie, Huimin

    2015-09-10

    By using the principle of stereovision, 3D digital image correlation (3D-DIC) can determine the 3D morphology and deformation of a target and has been widely used in experimental mechanics as a noncontact 3D measurement technique. To eliminate the limitations of the conventional 3D-DIC system, this study proposes a calibration-free single-lens 3D-DIC system based on a bilateral telecentric lens and a bi-prism. The performance of the proposed system is verified by tests of rigid-body translation along the out-of-plane direction. As a comparison, the same rigid-body translations are measured using a single-entocentric-lens 3D-DIC system. The results show that the measurement accuracy of the proposed system is higher than that of the entocentric-lens-based one. As an application, the proposed system is used to measure the thermal linear expansion of a ceramic plate at elevated temperatures. The reasonable measurement results verify its applicability in deformation measurements, even in high-temperature environments.

  11. Comparison of unilateral and simultaneous bilateral measurement of the globe position, using the Hertel exophthalmometer.

    LENUS (Irish Health Repository)

    Ameri, Hossein

    2012-02-03

    PURPOSE: To assess the effect of simultaneous measurement of the two eyes in Hertel exophthalmometry (i.e., when both readings are taken sequentially, without removing the instrument from the orbital rims) and to find out whether simultaneous measurement would influence the final reading of each eye. METHODS: In this prospective, comparative study, Hertel exophthalmometry was performed on 61 patients by two experienced observers. Only patients with no history of orbital disease were included. Three different measurements were performed on each patient by each observer. Initially, the right eye was measured separately, then the left eye was measured separately, and finally, both eyes were measured together. RESULTS: When the eyes were measured separately, in 30% of cases observers obtained equal readings in both eyes; in 47%, the difference between the two eyes was 1 mm; and in 23%, the difference was 2 mm or more. However, in simultaneous bilateral measurements, in 73% of cases, observers obtained equal readings in both eyes; in 24%, the difference between the two eyes was 1 mm; and only in 3% was the difference 2 mm or greater. Paired t tests showed that the mean difference between measurements of the two eyes was significantly smaller in simultaneous bilateral measurements (p <0.001). Interobserver variation was similar for measurements taken separately on each eye and for simultaneous bilateral measurements. CONCLUSIONS: When both eyes were measured simultaneously with the Hertel exophthalmometer, examiners were inclined to obtain similar readings in both eyes of patients with symmetrical-appearing eyes. The possible bias arising this way may reduce the reliability of Hertel exophthalmometer in relative exophthalmometry.

  12. Insect Wing Displacement Measurement Using Digital Holography

    International Nuclear Information System (INIS)

    Aguayo, Daniel D.; Mendoza Santoyo, Fernando; Torre I, Manuel H. de la; Caloca Mendez, Cristian I.

    2008-01-01

    Insects in flight have been studied with optical non destructive techniques with the purpose of using meaningful results in aerodynamics. With the availability of high resolution and large dynamic range CCD sensors the so called interferometric digital holographic technique was used to measure the surface displacement of in flight insect wings, such as butterflies. The wings were illuminated with a continuous wave Verdi laser at 532 nm, and observed with a CCD Pixelfly camera that acquire images at a rate of 11.5 frames per second at a resolution of 1392x1024 pixels and 12 Bit dynamic range. At this frame rate digital holograms of the wings were captured and processed in the usual manner, namely, each individual hologram is Fourier processed in order to find the amplitude and phase corresponding to the digital hologram. The wings displacement is obtained when subtraction between two digital holograms is performed for two different wings position, a feature applied to all consecutive frames recorded. The result of subtracting is seen as a wrapped phase fringe pattern directly related to the wing displacement. The experimental data for different butterfly flying conditions and exposure times are shown as wire mesh plots in a movie of the wings displacement

  13. Measurement-device-independent quantum digital signatures

    Science.gov (United States)

    Puthoor, Ittoop Vergheese; Amiri, Ryan; Wallden, Petros; Curty, Marcos; Andersson, Erika

    2016-08-01

    Digital signatures play an important role in software distribution, modern communication, and financial transactions, where it is important to detect forgery and tampering. Signatures are a cryptographic technique for validating the authenticity and integrity of messages, software, or digital documents. The security of currently used classical schemes relies on computational assumptions. Quantum digital signatures (QDS), on the other hand, provide information-theoretic security based on the laws of quantum physics. Recent work on QDS Amiri et al., Phys. Rev. A 93, 032325 (2016);, 10.1103/PhysRevA.93.032325 Yin, Fu, and Zeng-Bing, Phys. Rev. A 93, 032316 (2016), 10.1103/PhysRevA.93.032316 shows that such schemes do not require trusted quantum channels and are unconditionally secure against general coherent attacks. However, in practical QDS, just as in quantum key distribution (QKD), the detectors can be subjected to side-channel attacks, which can make the actual implementations insecure. Motivated by the idea of measurement-device-independent quantum key distribution (MDI-QKD), we present a measurement-device-independent QDS (MDI-QDS) scheme, which is secure against all detector side-channel attacks. Based on the rapid development of practical MDI-QKD, our MDI-QDS protocol could also be experimentally implemented, since it requires a similar experimental setup.

  14. Bilateral Comparison CIEMAT-CENTIS-DMR for radionuclide activity measurements; Comparacion Bilateral CIEMAT-CENTIS-DMR de la Medida de Actividad de Radionucleidos

    Energy Technology Data Exchange (ETDEWEB)

    Oropesa Verdecia, P.; Garcia-Torano, E.

    2004-07-01

    We present the results of a bilateral comparison of radionuclide activity measurements between the Radionuclide Metrology Department of the Center of Isotopes of Cuba (CENTIS-DMR), and the Ionising Radiation Metrology Laboratory (LMRI) of the Centro de Investigaciones Energeticas, Medioambientales y Tecnologicas (CIEMAT) of Spain. The aim of the comparison was to establish the comparability of the measurement instruments and methods used to obtain radioactive reference materials of some gamma-emitting nuclides at CENTIS-DMR. The results revealed that there are no statistically significant differences between the data reported by both laboratories. (Author) 7 refs.

  15. Objective assessment of actual chewing side by measurement of bilateral masseter muscle electromyography.

    Science.gov (United States)

    Yamasaki, Yo; Kuwatsuru, Rika; Tsukiyama, Yoshihiro; Matsumoto, Hiroshi; Oki, Kyosuke; Koyano, Kiyoshi

    2015-12-01

    The aim of this study was to examine the validity of objective assessment of actual chewing side by measurement of electromyographic (EMG) activity of the bilateral masseter muscles upon chewing test foods. The sample consisted of 19 healthy, dentate individuals. The subjects were asked to chew three types of test foods (peanuts, beef jerky, and chewing gum) for 10 strokes on the right side and then on the left side, and instructed to perform maximum voluntary clenching for 3s, three times. EMG activity from the bilateral masseter muscles was recorded. The data were collected in three different days. The root mean square EMG amplitude obtained from the maximum clenching task was used as the maximum voluntary contraction (MVC). Then, the level of amplitude against the MVC (%MVC) was calculated for the right and left sides on each stroke. The side with the larger %MVC value was judged as the chewing side, and the concordance rates (CRs) for the instructed chewing side (ICS) and the judged chewing side (JCS) were calculated. Intraclass correlation coefficients (ICCs) of the CRs were calculated to evaluate the reproducibility of the method. High CRs between the ICS and JCS for each test food were recognized. There were significant ICCs for beef jerky (R=0.761, Pchewing gum (R=0.785, Pchewing side during mastication. Copyright © 2015 Elsevier Ltd. All rights reserved.

  16. Library performance measurement in the digital age

    OpenAIRE

    Conyers, A.; Payne, Philip

    2011-01-01

    Book synopsis: University libraries around the world have embraced the possibilities of the digital learning environment, facilitating its use and proactively seeking to develop the provision of electronic resources and services. The digital environment offers opportunities and challenges for librarians in all aspects of their work - in information literacy, virtual reference, institutional repositories, e-learning, managing digital resources and social media. The authors in this timely book ...

  17. Measuring food intake with digital photography.

    Science.gov (United States)

    Martin, C K; Nicklas, T; Gunturk, B; Correa, J B; Allen, H R; Champagne, C

    2014-01-01

    The digital photography of foods method accurately estimates the food intake of adults and children in cafeterias. When using this method, images of food selection and leftovers are quickly captured in the cafeteria. These images are later compared with images of 'standard' portions of food using computer software. The amount of food selected and discarded is estimated based upon this comparison, and the application automatically calculates energy and nutrient intake. In the present review, we describe this method, as well as a related method called the Remote Food Photography Method (RFPM), which relies on smartphones to estimate food intake in near real-time in free-living conditions. When using the RFPM, participants capture images of food selection and leftovers using a smartphone and these images are wirelessly transmitted in near real-time to a server for analysis. Because data are transferred and analysed in near real-time, the RFPM provides a platform for participants to quickly receive feedback about their food intake behaviour and to receive dietary recommendations for achieving weight loss and health promotion goals. The reliability and validity of measuring food intake with the RFPM in adults and children is also reviewed. In sum, the body of research reviewed demonstrates that digital imaging accurately estimates food intake in many environments and it has many advantages over other methods, including reduced participant burden, elimination of the need for participants to estimate portion size, and the incorporation of computer automation to improve the accuracy, efficiency and cost-effectiveness of the method. © 2013 The British Dietetic Association Ltd.

  18. Continuous measurement of digital game experiences

    NARCIS (Netherlands)

    Poels, K.; Hoogen, van den W.M.; IJsselsteijn, W.A.; Kort, de Y.A.W.

    2008-01-01

    In recent years, the game industry has developed a wide array of games and gaming devices, targeted to different age and gender groups and to gamers with various play styles. As such, playing digital games has become a highly popular leisure activity. Over recent years, academic research on digital

  19. Measuring Trust: Standards for Trusted Digital Repositories

    Science.gov (United States)

    Dryden, Jean

    2011-01-01

    Ensuring the long-term preservation and use of born-digital and digitized records of enduring value has preoccupied archivists and their cultural heritage siblings for several decades. The professional literature of the 1980s and 1990s bemoans the challenges posed by rapid technological change (and the concomitant obsolescence of hardware and…

  20. Saddle-nose and bilateral cauliflower ear deformities with pyoderma gangrenosum-like ulcers, cavitary pulmonary lesions, digital gangrene and pulselessness in a young female.

    Science.gov (United States)

    Subhadarshani, Sweta; Gupta, Vishal; Chahal, Anurag; Verma, Kaushal K

    2017-06-15

    We report a young female who presented with saddle-nose and bilateral cauliflower ear deformities along with pyoderma gangrenosum-like ulcers, digital gangrene and pulselessness. Subsequently, she was found to have bilateral conductive hearing loss, a corneal opacity, mild aortic regurgitation and radiological evidence of cavitary changes in lungs and aortoarteritis. Our patient had a constellation of symptoms which posed a diagnostic challenge. Finally, a diagnosis of relapsing polychondritis with several unusual features was made. Overlap with Takayasu's arteritis and granulomatosis with polyangitis, which has been reported rarely in the literature, cannot be excluded. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  1. Measuring digit lengths with 3D digital stereophotogrammetry: A comparison across methods.

    Science.gov (United States)

    Gremba, Allison; Weinberg, Seth M

    2018-05-09

    We compared digital 3D stereophotogrammetry to more traditional measurement methods (direct anthropometry and 2D scanning) to capture digit lengths and ratios. The length of the second and fourth digits was measured by each method and the second-to-fourth ratio was calculated. For each digit measurement, intraobserver agreement was calculated for each of the three collection methods. Further, measurements from the three methods were compared directly to one another. Agreement statistics included the intraclass correlation coefficient (ICC) and technical error of measurement (TEM). Intraobserver agreement statistics for the digit length measurements were high for all three methods; ICC values exceeded 0.97 and TEM values were below 1 mm. For digit ratio, intraobserver agreement was also acceptable for all methods, with direct anthropometry exhibiting lower agreement (ICC = 0.87) compared to indirect methods. For the comparison across methods, the overall agreement was high for digit length measurements (ICC values ranging from 0.93 to 0.98; TEM values below 2 mm). For digit ratios, high agreement was observed between the two indirect methods (ICC = 0.93), whereas indirect methods showed lower agreement when compared to direct anthropometry (ICC < 0.75). Digit measurements and derived ratios from 3D stereophotogrammetry showed high intraobserver agreement (similar to more traditional methods) suggesting that landmarks could be placed reliably on 3D hand surface images. While digit length measurements were found to be comparable across all three methods, ratios derived from direct anthropometry tended to be higher than those calculated indirectly from 2D or 3D images. © 2018 Wiley Periodicals, Inc.

  2. Measurements of the Characteristics of Transparent Material Using Digital Holography

    Directory of Open Access Journals (Sweden)

    Ding Yu

    2013-01-01

    Full Text Available Digital holography is applied to measure the characteristics of transparent material. A digital hologram recording system to measure the surface of transparent material was established, and the digital holograms of transparent object were obtained in high quality. For postprocessing of hologram, the least-squares phase unwrapping algorithm was used in phase unwrapping, and the phase reconstruction image of transparent object was obtained. The information of material surfaces was measured and the characteristic was presented in 3D visualization. The validation experiment was conducted by NanoMap 500LS system; the results of validation experiment are well satisfied with the measurement by digital holography, which proved the feasibility of digital holographic technology as a good measurement tool for transparent material.

  3. Micro-Structure Measurement and Imaging Based on Digital Holography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kyeong Suk; Jung, Hyun Chul; Chang, Ho Seob; Akhter, Naseem [Chosun University, Gwangju (Korea, Republic of); Kee, Chang Doo [Chonnam National University, Gwangju (Korea, Republic of)

    2010-06-15

    Advancements in the imaging and computing technology have opened the path to digital holography for non-destructive investigations of technical samples, material property measurement, vibration analysis, flow visualization and stress analysis in aerospace industry which has widened the application of digital holography in the above fields. In this paper, we demonstrate the non-destructive investigation and micro-structure measurement application of digital holography to the small particles and a biological sample. This paper gives a brief description of the digital holograms recorded with this system and illustratively demonstrated

  4. Micro-Structure Measurement and Imaging Based on Digital Holography

    International Nuclear Information System (INIS)

    Kim, Kyeong Suk; Jung, Hyun Chul; Chang, Ho Seob; Akhter, Naseem; Kee, Chang Doo

    2010-01-01

    Advancements in the imaging and computing technology have opened the path to digital holography for non-destructive investigations of technical samples, material property measurement, vibration analysis, flow visualization and stress analysis in aerospace industry which has widened the application of digital holography in the above fields. In this paper, we demonstrate the non-destructive investigation and micro-structure measurement application of digital holography to the small particles and a biological sample. This paper gives a brief description of the digital holograms recorded with this system and illustratively demonstrated

  5. Measuring food intake with digital photography

    Science.gov (United States)

    The Digital Photography of Foods Method accurately estimates the food intake of adults and children in cafeterias. With this method, images of food selection and leftovers are quickly captured in the cafeteria. These images are later compared with images of 'standard' portions of food using computer...

  6. Digital image technology and a measurement tool in physical models

    CSIR Research Space (South Africa)

    Phelp, David

    2006-05-01

    Full Text Available Advances in digital image technology has allowed us to use accurate, but relatively cost effective technology to measure a number of varied activities in physical models. The capturing and manipulation of high resolution digital images can be used...

  7. Relationship between selected measures of strength and hip and knee excursion during unilateral and bilateral landings in women.

    Science.gov (United States)

    McCurdy, Kevin; Walker, John; Armstrong, Rusty; Langford, George

    2014-09-01

    The purpose of this study was to compare the relationship between several measures of single-joint, isometric, eccentric, and squat strength and unilateral and bilateral landing mechanics at the hip and knee in women. Twenty six healthy female subjects with previous athletic experience (height, 165.1 ± 7.01 cm; mass, 60.91 ± 7.14 kg; age, 20.9 ± 1.62 years) participated in this study. Hip and knee mechanics were measured using the MotionMonitor capture system (Innovative Sports Training, Inc.) with 3-dimensional electromagnetic sensors during bilateral (60 cm) and unilateral drop jumps (30 cm). On a separate day, isometric hip extension, external rotation, and abduction strength (lbs) were measured using a handheld dynamometer (Hoggan Health Industries, Inc.). Eccentric and isometric knee strength were measured on the Biodex IV Isokinetic Dynamometer (Biodex Medical Systems, Inc.). Free weight was used to measure the bilateral squat and a modified single-leg squat. The strongest correlations were found between squat strength and knee valgus (-0.77 ≤ r ≤ -0.83) and hip adduction (-0.5 ≤ r ≤ -0.65). After controlling for squat strength, hip external rotation strength and unilateral knee valgus (-0.41), hip abduction strength and bilateral knee valgus (-0.43), and knee flexion strength and bilateral hip adduction (-0.57) remained significant. Eccentric knee flexion strength and unilateral knee internal rotation was the only significant correlation for eccentric strength (-0.40). Squat strength seems to be the best predictor of knee valgus and was consistently related to hip adduction. Isometric and eccentric measures demonstrated few significant correlations with hip and knee excursion while demonstrating a low-to-moderate relationship. Hip and knee flexion and rotation do not seem to be related to strength. Squat strength should receive consideration during risk assessment for noncontact knee injury.

  8. Measurement of radiation dose to the eye-lens with bilateral whole brain irradiation

    International Nuclear Information System (INIS)

    Kim, Ki Hwan; Park, Charn Il; Kang, Wee Saing; Choo, Dong Woon

    1985-01-01

    In 40 patients with metastatic brain tumor and acute lymphoblastic leukemia received whole brain irradiation, the dose delivered to the eye lens was measured using T.L.D. chips applied on the eyes as usual shield. The dose to the eye lens was expressed the relative dose to the mid brain dose. Radiotherapy was administrated using Co-60 teletherapy with bilateral whole brain irradiation. The results are as follows: 1. The dose to the right eye from its incipient field is 16.6% of tumor dose while the dose to the same eye from the opposite field is 41.2%. On left eye, 19.2% from incipient field while 39.2% from the opposite field. 2. Total received dose to right and left eyes is 28.9%, 29.8% of tumor dose respectively. 3. Comparing lens shield group with orbit shield group dose is 22.5%, 15.8% of tumor dose, respectively. 4. The dose delivered to the eye lens in ipsilateral side depends upon internal scattering, location of lead shield and penetrating dose of lead in itself. The dose in contralateral side depends upon divergency of radiation beam and patient's malposition. 5. The dose to the eye lens should be less than 10% of tumor dose with adequate shield, also not missing the chance of leptomeningeal recurrence because of overshielding.

  9. Measuring food intake with digital photography

    OpenAIRE

    Martin, Corby K.; Nicklas, Theresa; Gunturk, Bahadir; Correa, John B.; Allen, H. Raymond; Champagne, Catherine

    2013-01-01

    The Digital Photography of Foods Method accurately estimates the food intake of adults and children in cafeterias. When using this method, imags of food selection and leftovers are quickly captured in the cafeteria. These images are later compared to images of “standard” portions of food using a computer application. The amount of food selected and discarded is estimated based upon this comparison, and the application automatically calculates energy and nutrient intake. Herein, we describe th...

  10. Measuring Digital Signage ROI : A combination of Digital Signage and Mobile Advertising as a method for measuring Digtal Signage ROI

    OpenAIRE

    Helander, Fredrik

    2010-01-01

    Marketing has changed a lot the past decade. New modern marketing channels have been developed and marketing have become more effective. This has affected the expectations advertisers have on advertising channels. One thing advertisers increasingly expect is to be able to efficiently measure the result of advertising, the ROI. A method for measuring ROI of digital signage is in focus in this study. The measurement is enabled by a combination of digital signage and mobile advertising. First a ...

  11. Measuring and Bridging the Gender Digital Divide in Rural Pakistan ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Measuring and Bridging the Gender Digital Divide in Rural Pakistan ... to critically examining the gender-specific aspects of ICT use and its impact on development in ... In partnership with UNESCO's Organization for Women in Science for the ...

  12. Noise Reduction of Measurement Data using Linear Digital Filters

    Directory of Open Access Journals (Sweden)

    Hitzmann B.

    2007-12-01

    Full Text Available In this paper Butterworth, Chebyshev (Type I and II and Elliptic digital filters are designed for signal noise reduction. On-line data measurements of substrate concentration from E. coli fed-batch cultivation process are used. Application of the designed filters leads to a successful noise reduction of on-line glucose measurements. The digital filters presented here are simple, easy to implement and effective - the used filters allow for a smart compromise between signal information and noise corruption.

  13. Influence of Signal Stationarity on Digital Stochastic Measurement Implementation

    Directory of Open Access Journals (Sweden)

    Ivan Župunski

    2013-06-01

    Full Text Available The paper presents the influence of signal stationarity on digital stochastic measurement method implementation. The implementation method is based on stochastic voltage generators, analog adders, low resolution A/D converter, and multipliers and accumulators implemented by Field-Programmable Gate Array (FPGA. The characteristic of first implementations of digital stochastic measurement was the measurement of stationary signal harmonics over the constant measurement period. Later, digital stochastic measurement was extended and used also when it was necessary to measure timeseries of non-stationary signal over the variable measurement time. The result of measurement is the set of harmonics, which is, in the case of non-stationary signals, the input for calculating digital values of signal in time domain. A theoretical approach to determine measurement uncertainty is presented and the accuracy trends with varying signal-to-noise ratio (SNR are analyzed. Noisy brain potentials (spontaneous and nonspontaneous are selected as an example of real non-stationary signal and its digital stochastic measurement is tested by simulations and experiments. Tests were performed without noise and with adding noise with SNR values of 10dB, 0dB and - 10dB. The results of simulations and experiments are compared versus theory calculations, and comparasion confirms the theory.

  14. Measurement methods to build up the digital optical twin

    Science.gov (United States)

    Prochnau, Marcel; Holzbrink, Michael; Wang, Wenxin; Holters, Martin; Stollenwerk, Jochen; Loosen, Peter

    2018-02-01

    The realization of the Digital Optical Twin (DOT), which is in short the digital representation of the physical state of an optical system, is particularly useful in the context of an automated assembly process of optical systems. During the assembly process, the physical system status of the optical system is continuously measured and compared with the digital model. In case of deviations between physical state and the digital model, the latter one is adapted to match the physical state. To reach the goal described above, in a first step measurement/characterization technologies concerning their suitability to generate a precise digital twin of an existing optical system have to be identified and evaluated. This paper gives an overview of possible characterization methods and, finally, shows first results of evaluated, compared methods (e.g. spot-radius, MTF, Zernike-polynomials), to create a DOT. The focus initially lies on the unequivocalness of the optimization results as well as on the computational time required for the optimization to reach the characterized system state. Possible sources of error are the measurement accuracy (to characterize the system) , execution time of the measurement, time needed to map the digital to the physical world (optimization step) as well as interface possibilities to integrate the measurement tool into an assembly cell. Moreover, it is to be discussed whether the used measurement methods are suitable for a `seamless' integration into an assembly cell.

  15. Quality Measures for Digital Business Ecosystems Formation

    Science.gov (United States)

    Raza, Muhammad; Hussain, Farookh Khadeer; Chang, Elizabeth

    To execute a complex business task, business entities may need to collaborate with each other as individually they may not have the capability or willingness to perform the task on its own. Such collaboration can be seen implemented in digital business ecosystems in the form of simple coalitions using multi-agent systems or by employing Electronic Institutions. A major challenge is choosing optimal partners who will deliver the agreed commitments, and act in the coalition’s interest. Business entities are scaled according to their quality level. Determining the quality of previously unknown business entities and predicting the quality of such an entity in a dynamic environment are crucial issues in Business Ecosystems. A comprehensive quality management system grounded in the concepts of Trust and Reputation can help address these issues.

  16. Digital Divide Measurement in Lembata Regency Using SIBIS

    Science.gov (United States)

    Gabriel, Cecilia Dai Payon Binti; Setyohadi, Djoko Budiyanto; Suyoto

    2018-02-01

    Along with technological development in Indonesia, digital divide occurs in various regions, which were behind in terms of information on how to use, access and utilize ICT in collecting information from internet. One of the regions is Lembata Regency in East Nusa Tenggara, where digital divide among the people should be measured. The purpose of this study was to determine the level of digital divide among the people of Lembata Regency. To determine the level of digital divide, we used SIBIS GPS (General Population Survey) method, which consisted of several indicators or aspect, i.e. internet usage behavior, internet utilization, and e-government. We also performed two tests, i.e. validity test and reliability test to obtain value of index of digital divide measurement among the people of Lembata Regency. The results of validity test which is processed using SPSS program are categorized valid for each variable indicator and the reliability test results show reliable status. According to the test results on digital discrepancy in Lembata people, the internet usage attitude indicator is categorized low which is 63.1%, the internet usage function indicator is categorized low which is 64%, and the digital discrepancy of e-government indicator is categorized medium which is 40.4%. Therefore, the result of this study because consideration for the government of Lembata Regency in improving ICT services in e-government and in distributing ICT access and ability equally to the people.

  17. Application of digital beam position processor Libera on tune measurement

    International Nuclear Information System (INIS)

    Zhang Chunhui; Sun Baogen; Cao Yong; Lu Ping; Li Jihao

    2006-01-01

    Digital signal processing (DSP) is widely used in the field of beam diagnostics. Especially, DSP achieves very good performance in beam position signal analysis and betatron tune measurement. In Hefei light source, when beam was excited by narrow-band Gaussian white nose, Libera, a digital beam position processor, was used to process the signals from beam position monitor (BPM), which contained betatron oscillation. Fast Fourier transform (FFT) was applied to finding out betatron resonance frequency, from which the decimal part of betatron oscillation tune was calculated. By this means, the measure of horizontal tune was 3.5352 and the measure of vertical tune is 2.6299. (authors)

  18. UMTS signal measurements with digital spectrum analysers

    International Nuclear Information System (INIS)

    Licitra, G.; Palazzuoli, D.; Ricci, A. S.; Silvi, A. M.

    2004-01-01

    The launch of the Universal Mobile Telecommunications System (UNITS), the most recent mobile telecommunications standard has imposed the requirement of updating measurement instrumentation and methodologies. In order to define the most reliable measurement procedure, which is aimed at assessing the exposure to electromagnetic fields, modern spectrum analysers' features for correct signal characterisation has been reviewed. (authors)

  19. Bilateral comparison between PTB and ENEA to check the performance of a commercial TDCR system for activity measurements

    International Nuclear Information System (INIS)

    Kossert, Karsten; Capogni, Marco; Nähle, Ole J.

    2014-01-01

    The only commercial TDCR counter from Hidex Oy (Finland), comprising three photomultiplier tubes, was tested at the two National Metrology Institutes (NMIs) PTB and ENEA. To this end, the two NMIs purchased a Hidex 300 SL TDCR counter (METRO version) each and carried out various tests at their laboratories. In addition, the two institutions agreed to organize a bilateral comparison in order to acquire information on the reproducibility of the results obtained with the counters. To achieve this, PTB prepared some 89 Sr liquid scintillation samples, which were first measured in various counters at PTB and then shipped to ENEA for comparative measurements. The aim of this paper is to summarize the findings on the counter characteristics and adjustments. In addition, the results of the bilateral comparison between PTB and ENEA are presented and the results from various commercial counters using the CIEMAT/NIST efficiency tracing and the TDCR method are discussed. - Highlights: • The TDCR counter from Hidex Oy was tested at PTB and ENEA. • The studies comprised linearity checks and investigation of adjustments. • A bilateral 89 Sr comparison was organized to compare two Hidex counters

  20. Digital measurement system for the LHC klystron high voltage modulator.

    CERN Document Server

    Mikkelsen, Anders

    Accelerating voltage in the Large Hadron Collider (LHC) is created by a means of 16 superconducting standing wave RF cavities, each fed by a 400MHz/300kW continuous wave klystron amplifier. Part of the upgrade program for the LHC long shutdown one is to replace the obsolete analogue current and voltage measurement circuitry located in the high voltage bunkers by a new, digital system, using ADCs and optical fibres. A digital measurement card is implemented and integrated into the current HV modulator oil tank (floating at -58kV) and interfaced to the existing digital VME boards collecting the data for several klystrons at the ground potential. Measured signals are stored for the logging, diagnostics and post-mortem analysis purposes.

  1. Digital auscultation of the uterine artery: a measure of uteroplacental perfusion.

    Science.gov (United States)

    Riknagel, Diana; Dinesen, Birthe; Zimmermann, Henrik; Farlie, Richard; Schmidt, Samuel; Toft, Egon; Struijk, Johannes Jan

    2016-07-01

    This observational study investigated digital auscultation for the purpose of assessing the clinical feasibility of monitoring vascular sounds in pregnancy. The study was performed at the Regional Hospital Viborg, Denmark, and included 29 pregnant women, 10 non-pregnant women and 10 male participants. Digital auscultation was performed with an electronic stethoscope bilaterally near the uterine arteries and correlated to the clinical diagnosis of preeclampsia (PE), intrauterine growth restriction (IUGR) or normal pregnancy in the group of pregnant participants. In the group of non-pregnant participants, digital auscultation was performed as control measurements in the same anatomical positions. The auscultations displayed pulse waveforms comprising systolic and diastolic periods in 20 of the 29 pregnant participants. However, in the non-pregnant and male participants, the pulse waveforms were absent. The pulsatile patterns are thus likely to originate from the arteries in relation to the pregnant uterus. In the participants displaying pulse waveforms, the presence of a dicrotic notch appeared with a sensitivity of 89% and a specificity of 100% in the discrimination of normal pregnancies (n  =  11) from pregnancies with PE or IUGR (n  =  9), (p  <  0.001). This preliminary study shows the potential of identifying vascular complications during pregnancy such as preeclampsia and intrauterine growth restriction. The morphology of the derived pulse contour should be investigated and could be further developed to identify pathophysiology.

  2. Digital PCR as a tool to measure HIV persistence.

    Science.gov (United States)

    Rutsaert, Sofie; Bosman, Kobus; Trypsteen, Wim; Nijhuis, Monique; Vandekerckhove, Linos

    2018-01-30

    Although antiretroviral therapy is able to suppress HIV replication in infected patients, the virus persists and rebounds when treatment is stopped. In order to find a cure that can eradicate the latent reservoir, one must be able to quantify the persisting virus. Traditionally, HIV persistence studies have used real-time PCR (qPCR) to measure the viral reservoir represented by HIV DNA and RNA. Most recently, digital PCR is gaining popularity as a novel approach to nucleic acid quantification as it allows for absolute target quantification. Various commercial digital PCR platforms are nowadays available that implement the principle of digital PCR, of which Bio-Rad's QX200 ddPCR is currently the most used platform in HIV research. Quantification of HIV by digital PCR is proving to be a valuable improvement over qPCR as it is argued to have a higher robustness to mismatches between the primers-probe set and heterogeneous HIV, and forfeits the need for a standard curve, both of which are known to complicate reliable quantification. However, currently available digital PCR platforms occasionally struggle with unexplained false-positive partitions, and reliable segregation between positive and negative droplets remains disputed. Future developments and advancements of the digital PCR technology are promising to aid in the accurate quantification and characterization of the persistent HIV reservoir.

  3. Digital module for neutron flux measurement by Campbell method

    International Nuclear Information System (INIS)

    Baratte, G.

    1987-02-01

    The study reported here concerns a wide range measurement channel for reactor control instrumentation but it may also be useful for specific measurements requiring the Campbell method. A wide range measurement channel allows the processing of the signal issued from a single fission chamber so it's possible to insure control of nuclear reactors in three different running modes: pulse processing, fluctuations and current. The study described in this note includes three parts: - the analogical wide range neutron measurement channel is presented in the first chapter; the fluctuation mode is thoroughly studied; the results of tests and proper limitations of analogical processing are summarized. A theoretical study of the neutron flux measurement by numerical calculation of the fluctuation signal variance is given in the second chapter. The digital module is described in the third chapter; the results of experiments are analysed. The validity of the digital method is proved by means of a practical realisation. The performances obtained with the digital fluctuation test model may be compared with those given by the analogical fluctuation channel which can be used for the control of lower fission rates. The digital module may also be used for any fluctuation measurement where very short response time and broad spectral band of analysis are not strictly necessary [fr

  4. Field-Deployable Acoustic Digital Systems for Noise Measurement

    Science.gov (United States)

    Shams, Qamar A.; Wright, Kenneth D.; Lunsford, Charles B.; Smith, Charlie D.

    2000-01-01

    Langley Research Center (LaRC) has for years been a leader in field acoustic array measurement technique. Two field-deployable digital measurement systems have been developed to support acoustic research programs at LaRC. For several years, LaRC has used the Digital Acoustic Measurement System (DAMS) for measuring the acoustic noise levels from rotorcraft and tiltrotor aircraft. Recently, a second system called Remote Acquisition and Storage System (RASS) was developed and deployed for the first time in the field along with DAMS system for the Community Noise Flight Test using the NASA LaRC-757 aircraft during April, 2000. The test was performed at Airborne Airport in Wilmington, OH to validate predicted noise reduction benefits from alternative operational procedures. The test matrix was composed of various combinations of altitude, cutback power, and aircraft weight. The DAMS digitizes the acoustic inputs at the microphone site and can be located up to 2000 feet from the van which houses the acquisition, storage and analysis equipment. Digitized data from up to 10 microphones is recorded on a Jaz disk and is analyzed post-test by microcomputer system. The RASS digitizes and stores acoustic inputs at the microphone site that can be located up to three miles from the base station and can compose a 3 mile by 3 mile array of microphones. 16-bit digitized data from the microphones is stored on removable Jaz disk and is transferred through a high speed array to a very large high speed permanent storage device. Up to 30 microphones can be utilized in the array. System control and monitoring is accomplished via Radio Frequency (RF) link. This paper will present a detailed description of both systems, along with acoustic data analysis from both systems.

  5. Measurement of Piezoelectric Transformer Vibrations by Digital Holography

    Czech Academy of Sciences Publication Activity Database

    Psota, Pavel; Lédl, Vít; Doleček, Roman; Erhart, J.; Kopecký, V.

    2014-01-01

    Roč. 59, č. 9 (2014), s. 1962-1968 ISSN 0885-3010 R&D Projects: GA MŠk(CZ) ED2.1.00/03.0079 Institutional support: RVO:61389021 Keywords : digital holographic * ime-averaged holographic * small amplitude * vibrations amplitude measurement * piezoelectric transformer s Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 1.512, year: 2014

  6. The measurement of the modal strain fields using digital shearography

    Directory of Open Access Journals (Sweden)

    Gomes J.M.

    2010-06-01

    Full Text Available This work presents a Michelson shearography interferometer configuration associated with stroboscopic double illumination technique for the measurement of modal rotation fields and their strain fields on a clamped circular aluminium plate. The speckle pattern is frozen by the synchronization between the LASER illumination and the modal vibration of the object. The quantitative evaluation is performed for each digital shearogram using a time modulation technique. The setup of double illumination LASER with out-of-plane opposite sensitivity allows the two phase maps measurement of the modal spatial gradient. The modal rotation and strain fields are extracted by the combination of this two digital phase maps. Image processing techniques are applied on the phase maps to obtain full-field measurements using a dedicated post-processing algorithm. Finally, is presented a comparison between the experimental measurement and the numerical solution.

  7. Clinical study of cerebral blood flow in bilateral chronic subdural hematoma measured by 99mTc-HMPAO SPECT

    International Nuclear Information System (INIS)

    Okuyama, Tohru; Saito, Koji; Fukuyama, Kohichi; Yamamoto, Kouki; Morimoto, Mamoru; Aburano, Tamio

    2000-01-01

    Cerebral blood flow (CBF) in 34 patients with bilateral chronic subdural hematoma was measured by 99m Tc-HMPAO SPECT before operation. The regional CBF was measured in 26 regions of the 10 cortical regions, putamen, thalamus and cerebellar hemisphere on both sides. According to the thickness of subdural hematoma, the thicker hematoma side was measured and examined as the thick hematoma side, and the other side as the thin hematoma side. Thirty four cases with bilateral chronic subdural hematoma were classified into four groups on the basis of clinical symptoms :13 cases with headache (headache group), 10 cases with hemiparesis (hemiparesis group), 5 cases with tetraparesis (tetraparesis group) and 6 cases with consciousness disturbance or dementia (consciousness disturbance group), and into two groups according to the degree of midline brain shift on MRI: 14 cases of non-shifted group and 20 cases of shifted group. The average CBF of 34 patients in each region indicated a regional CBF reduction in the frontal, parietal and occipital cortices on the thin hematoma side, and in the putamen on the thick hematoma side. In the headache group, the regional CBF reduction on the thin hematoma side was found in the frontal, parietal and occipital cortices compared with the corresponding regions on the thick hematoma side, and in thalamus on the thick hematoma side. In the hemiparesis and tetraparesis groups, there was no statistically significant CBF reduction between the thick and thin hematoma sides. In the consciousness disturbance group, the CBF reduction in whole brain was remarkably significant. By the degree of the midline brain shift, the CBF reductions between the thick and thin hematoma sides were observed. Namely, in the shifted group, the CBF reductions were noted in the frontal, parietal and occipital cortices in the thin hematoma side, and in the putamen in the thick hematoma side. We concluded that the CBF reduction of bilateral chronic subdural hematoma was

  8. Clinical study of cerebral blood flow in bilateral chronic subdural hematoma measured by {sup 99m}Tc-HMPAO SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Okuyama, Tohru; Saito, Koji; Fukuyama, Kohichi; Yamamoto, Kouki; Morimoto, Mamoru [Kushiro Neurosurgical Hospital, Hokkaido (Japan); Aburano, Tamio

    2000-08-01

    Cerebral blood flow (CBF) in 34 patients with bilateral chronic subdural hematoma was measured by {sup 99m}Tc-HMPAO SPECT before operation. The regional CBF was measured in 26 regions of the 10 cortical regions, putamen, thalamus and cerebellar hemisphere on both sides. According to the thickness of subdural hematoma, the thicker hematoma side was measured and examined as the thick hematoma side, and the other side as the thin hematoma side. Thirty four cases with bilateral chronic subdural hematoma were classified into four groups on the basis of clinical symptoms :13 cases with headache (headache group), 10 cases with hemiparesis (hemiparesis group), 5 cases with tetraparesis (tetraparesis group) and 6 cases with consciousness disturbance or dementia (consciousness disturbance group), and into two groups according to the degree of midline brain shift on MRI: 14 cases of non-shifted group and 20 cases of shifted group. The average CBF of 34 patients in each region indicated a regional CBF reduction in the frontal, parietal and occipital cortices on the thin hematoma side, and in the putamen on the thick hematoma side. In the headache group, the regional CBF reduction on the thin hematoma side was found in the frontal, parietal and occipital cortices compared with the corresponding regions on the thick hematoma side, and in thalamus on the thick hematoma side. In the hemiparesis and tetraparesis groups, there was no statistically significant CBF reduction between the thick and thin hematoma sides. In the consciousness disturbance group, the CBF reduction in whole brain was remarkably significant. By the degree of the midline brain shift, the CBF reductions between the thick and thin hematoma sides were observed. Namely, in the shifted group, the CBF reductions were noted in the frontal, parietal and occipital cortices in the thin hematoma side, and in the putamen in the thick hematoma side. We concluded that the CBF reduction of bilateral chronic subdural hematoma

  9. A digital instrument for reactivity measurements in a nuclear reactor

    International Nuclear Information System (INIS)

    Chwaszczewski, S.

    1979-01-01

    An instrument for digital determination of the reactivity in nuclear reactors is described. It is based on the CAMAC standard apparatus, suitable for the use of pulse or current type neutron detectors and operates with prompt response and an output signal proportional to the core neutron flux. The measured data of neutron flux and reactivity can be registered by a digital display unit, an indicator, or, by request of the operator, a paper type punch. The algorithms used for reactivity calculation are considered and the results of numerical studies on those algorithms are discussed. The instrument has been used for determining the reactivity of the control elements in the fast-thermal assembly ANNA and in the research reactor MARIA. Some results of these measurements are given. (author)

  10. Digital instrument for reactivity measurements in a nuclear reactor

    Energy Technology Data Exchange (ETDEWEB)

    Chwaszczewski, S [Institute of Nuclear Research, Warsaw (Poland)

    1979-07-01

    An instrument for digital determination of the reactivity in nuclear reactors is described. It is based on the CAMAC standard apparatus, suitable for the use of pulse or current type neutron detectors and operates with prompt response and an output signal proportional to the core neutron flux. The measured data of neutron flux and reactivity can be registered by a digital display unit, an indicator, or, by request of the operator, a paper type punch. The algorithms used for reactivity calculation are considered and the results of numerical studies on those algorithms are discussed. The instrument has been used for determining the reactivity of the control elements in the fast-thermal assembly ANNA and in the research reactor MARIA. Some results of these measurements are given.

  11. Accuracy of digital American Board of Orthodontics Discrepancy Index measurements.

    Science.gov (United States)

    Dragstrem, Kristina; Galang-Boquiren, Maria Therese S; Obrez, Ales; Costa Viana, Maria Grace; Grubb, John E; Kusnoto, Budi

    2015-07-01

    A digital analysis that is shown to be accurate will ease the demonstration of initial case complexity. To date, no literature exists on the accuracy of the digital American Board of Orthodontics Discrepancy Index (DI) calculations when applied to pretreatment digital models. Plaster models were obtained from 45 previous patients with varying degrees of malocclusion. Total DI scores and the target disorders were computed manually with a periodontal probe on the original plaster casts (gold standard) and digitally using Ortho Insight 3D (Motion View Software, Hixson, Tenn) and OrthoCAD (Cadent, Carlstadt, NJ). Intrarater and interrater reliabilities were assessed for 15 subjects using the Spearman rho correlation test. Accuracies of the DI scores and target disorders were assessed for all 45 subjects using Wilcoxon signed ranks tests. Intrarater and interrater reliabilities were high for total DI scores and most target disorders (r > 0.8). No significant difference was found between total DI score when measured with OrthoCAD compared with manual calculations. The total DI scores calculated by Ortho Insight 3D were found to be significantly greater than those by manual calculation by 2.71 points. The findings indicate that a DI calculated by Ortho Insight 3D may lead the clinician to overestimate case complexity. OrthoCAD's DI module was demonstrated to be a clinically acceptable alternative to manual calculation of the total scores. Copyright © 2015 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  12. Effectiveness of preventative and other surgical measures on hypocalcemia following bilateral thyroid surgery: a systematic review and meta-analysis.

    Science.gov (United States)

    Antakia, Ramez; Edafe, Ovie; Uttley, Lesley; Balasubramanian, Saba P

    2015-01-01

    A variety of measures have been proposed to reduce the incidence of post-thyroidectomy hypocalcemia. The aim of this study was to perform a systematic review and meta-analysis of preventive and other surgical measures on post-thyroidectomy hypocalcemia as reported in the literature. Comprehensive searches of the PubMed, EMBASE, and Cochrane databases were performed, and the quality of included papers was assessed using the Cochrane risk of bias tool or a modified Newcastle-Ottawa Scale (NOS). The results of all included studies were summarized, and meta-analyses were performed where appropriate. Thirty-nine randomized controlled trials (RCTs) and 37 observational studies were included. Measures studied included hemostatic techniques, extent of thyroidectomy and central neck dissection, surgical approach, calcium/vitamin D/thiazide diuretic supplements, parathyroid gland autotransplantation (PGAT) and intraoperative parathyroid gland (PG) identification, truncal ligation of inferior thyroid artery (ITA), preoperative magnesium infusion, and use of magnification loupes and Surgicel. Measures associated with significantly lower rates of transient hypocalcemia in meta-analysis were postoperative calcium and vitamin D supplementation compared to either calcium supplements alone (odds ratio (OR) 0.66; p=0.04) or no supplements (OR 0.34; p=0.007), and bilateral subtotal thyroidectomy (BST) compared to Hartley Dunhill (HD) procedure (OR 0.35; p=0.01). Meta-analyses did not demonstrate any measure to be significantly associated with a reduction in permanent hypocalcemia. This review identified postoperative calcium and vitamin D supplementation and bilateral subtotal thyroidectomy (over HD) as being effective in prevention of transient hypocalcemia. However, the majority of RCTs were of low quality, primarily due to a lack of blinding. The wide variability in study design, definitions of hypocalcemia, and methods of assessment prevented meaningful summation of results for

  13. Measurement of digital blood pressure after local cooling

    DEFF Research Database (Denmark)

    Nielsen, S L; Lassen, N A

    1977-01-01

    A double-inlet plastic cuff was designed for local cooling and systolic blood pressure measurement on the middle phalanx of the fingers. With a tourniquet on the proximal phalanx of one finger, cooling for 5 min made the digital artery temperature equal the skin temperature. The difference between...... the systolic pressure in a control finger and in the cooled finger give the reopening pressure in the digital arteries. At 30, 25, 20, 15, and 10 degrees C, respectively the percent decrease of the finger pressure was 0.2 (0.2), 1.5 (2.5), 8.5 (3.7), 11.4 (3.4), and 15.3 (3.1) in normal young women...

  14. High-speed digital holographic interferometry for vibration measurement

    International Nuclear Information System (INIS)

    Pedrini, Giancarlo; Osten, Wolfgang; Gusev, Mikhail E.

    2006-01-01

    A system based on digital holographic interferometry for the measurement of vibrations is presented. A high-power continuous laser(10 W) and a high-speed CCD camera are used. Hundreds of holograms of an object that has been subjected to dynamic deformation are recorded. The acquisition speed and the time of exposure of the detector are determined by the vibration frequency. Two methods are presented for triggering the camera in order to acquire at a given phase of the vibration. The phase of the wavefront is calculated from the recorded holograms by use of a two-dimensional digital Fourier-transform method. The deformation of the object is obtained from the phase. By combination of the deformations recorded at different times it is possible to reconstruct the vibration of the object

  15. A digital instantaneous frequency measurement technique utilising high speed analogue to digital converters and field programmable gate arrays

    CSIR Research Space (South Africa)

    Herselman, PLR

    2007-09-01

    Full Text Available In modern information and sensor systems, the timely estimation of the carrier frequency of received signals is of critical importance. This paper presents a digital instantaneous frequency measurement (DIFM) technique, which can measure the carrier...

  16. A digital method for period measurements in a nuclear reactor

    International Nuclear Information System (INIS)

    Mundim, Sergio Gorretta

    1971-02-01

    The present paper begins by giving a theoretical treatment for the nuclear reactor period. The conventional method of measuring the period is analysed and some previously developed digital methods are described. The paper criticises the latter, pointing out some deficiencies which the proposed process is able to eliminate. All errors connected with this process are also analysed. The paper presents suitable solutions to reduce them to a minimum. The total error is found to he less than the error presented by the other methods described. A digital period meter is designed with memory resources and an automatic scaler changer. Integrated circuits specifications are used in it. Real time experiments with nuclear reactors were made in order to check te validity of the method. The data acquired were applied to a simulated digital period meter implemented in a general purpose computer. The nuclear part of the work was developed at the 'Comissao Nacional de Energia Nuclear' and the simulation work was dane at the 'Departamento de Calculo Cientifico' of COPPE, which also advised the author in the completion of this thesis. (author)

  17. Measuring hot flash phenomenonology using ambulatory prospective digital diaries

    Science.gov (United States)

    Fisher, William I.; Thurston, Rebecca C.

    2016-01-01

    Objective This study provides the description, protocol, and results from a novel prospective ambulatory digital hot flash phenomenon diary. Methods This study included 152 midlife women with daily hot flashes who completed an ambulatory electronic hot flash diary continuously for the waking hours of 3 consecutive days. In this diary, women recorded their hot flashes and accompanying characteristics and associations as the hot flashes occurred. Results Self-reported hot flash severity on the digital diaries indicated that the majority of hot flashes were rated as mild (41.3%) or moderate (43.7%). Severe (13.1%) and very severe (1.8%) hot flashes were less common. Hot flash bother ratings were rated as mild (43%), or moderate (33.5%), with fewer hot flashes reported bothersome (17.5%) or very bothersome (6%). The majority of hot flashes were reported as occurring on the on the face (78.9%), neck (74.7%), and chest (61.3%). Prickly skin was reported concurrently with 32% of hot flashes, 7% with anxiety and 5% with nausea. A novel finding, 38% of hot flashes were accompanied by a premonitory aura. Conclusion A prospective electronic digital hot flash diary allows for a more precise quantitation of hot flashes while overcoming many of the limitations of commonly employed retrospective questionnaires and paper diaries. Unique insights into the phenomenology, loci and associated characteristics of hot flashes were obtained using this device. The digital hot flash phenomenology diary is recommended for future ambulatory studies of hot flashes as a prospective measure of the hot flash experience. PMID:27404030

  18. [Bilateral torticollis].

    Science.gov (United States)

    Kustos, T; Magdics, M

    1993-12-19

    Bilateral torticollis is a very rare form of a well known deformity i.e. muscular torticollis. This malformation might present a differential diagnostic problem both for orthopaedic surgeons and ophthalmologists, as well as, for neurologists. In agreement with the literature, the role of an injury during labour or defective embriogenesis is suggested to play a part.

  19. Refocusing criterion via sparsity measurements in digital holography.

    Science.gov (United States)

    Memmolo, Pasquale; Paturzo, Melania; Javidi, Bahram; Netti, Paolo A; Ferraro, Pietro

    2014-08-15

    Several automatic approaches have been proposed in the past to compute the refocus distance in digital holography (DH). However most of them are based on a maximization or minimization of a suitable amplitude image contrast measure, regarded as a function of the reconstruction distance parameter. Here we show that, by using the sparsity measure coefficient regarded as a refocusing criterion in the holographic reconstruction, it is possible to recover the focus plane and, at the same time, establish the degree of sparsity of digital holograms, when samples of the diffraction Fresnel propagation integral are used as a sparse signal representation. We employ a sparsity measurement coefficient known as Gini's index thus showing for the first time, to the best of our knowledge, its application in DH, as an effective refocusing criterion. Demonstration is provided for different holographic configurations (i.e., lens and lensless apparatus) and for completely different objects (i.e., a thin pure phase microscopic object as an in vitro cell, and macroscopic puppets) preparation.

  20. Measuring Claw Conformation in Cattle: Assessing the Agreement between Manual and Digital Measurement

    Directory of Open Access Journals (Sweden)

    Linda J. Laven

    2015-08-01

    Full Text Available Five measurements of claw conformation (toe angle, claw height, claw width, toe length and abaxial groove length taken directly from the hoof were compared with the measurements taken from digital images of the same claws. Concordance correlation coefficients and limits-of-agreement analysis showed that, for four of the five measures (claw height, claw width, toe length and abaxial groove length, agreement was too poor for digital and manual measures to be used interchangeably. For all four of these measures, Liao’s modified concordance correlation coefficient (mCCC was ≤0.4, indicating poor concordance despite Pearson’s correlation being >0.6 in all cases. The worst concordance was seen for toe length (mCCC = 0.13. Limits-of-agreement analysis showed that, for all four measures, there was a large variation in the difference between the manual and digital methods, even when the effect of mean on difference was accounted for, with the 95% limits-of-agreement for the four measures being further away from the mean difference than 10% of the mean in all four cases. The only one of the five measures with an acceptable concordance between digital and manual measurement was toe angle (mCCC = 0.81. Nevertheless, the limits-of-agreement analysis showed that there was a systematic bias with, on average, the manual measure of toe angle, being 2.1° smaller than the digital. The 95% limits-of-agreement for toe angle were ±3.4°, probably at the upper limit of what is acceptable. However, the lack of data on the variability of individual measurements of claw conformation means that it is unclear how this variability compares to measurement of toe angle in the same animal using the same or a different manual technique.

  1. Inter-arch digital model vs. manual cast measurements: Accuracy and reliability.

    Science.gov (United States)

    Kiviahde, Heikki; Bukovac, Lea; Jussila, Päivi; Pesonen, Paula; Sipilä, Kirsi; Raustia, Aune; Pirttiniemi, Pertti

    2017-06-28

    The purpose of this study was to evaluate the accuracy and reliability of inter-arch measurements using digital dental models and conventional dental casts. Thirty sets of dental casts with permanent dentition were examined. Manual measurements were done with a digital caliper directly on the dental casts, and digital measurements were made on 3D models by two independent examiners. Intra-class correlation coefficients (ICC), a paired sample t-test or Wilcoxon signed-rank test, and Bland-Altman plots were used to evaluate intra- and inter-examiner error and to determine the accuracy and reliability of the measurements. The ICC values were generally good for manual and excellent for digital measurements. The Bland-Altman plots of all the measurements showed good agreement between the manual and digital methods and excellent inter-examiner agreement using the digital method. Inter-arch occlusal measurements on digital models are accurate and reliable and are superior to manual measurements.

  2. Fully automated joint space width measurement and digital X-ray radiogrammetry in early RA.

    Science.gov (United States)

    Platten, Michael; Kisten, Yogan; Kälvesten, Johan; Arnaud, Laurent; Forslind, Kristina; van Vollenhoven, Ronald

    2017-01-01

    To study fully automated digital joint space width (JSW) and bone mineral density (BMD) in relation to a conventional radiographic scoring method in early rheumatoid arthritis (eRA). Radiographs scored by the modified Sharp van der Heijde score (SHS) in patients with eRA were acquired from the SWEdish FarmacOTherapy study. Fully automated JSW measurements of bilateral metacarpals 2, 3 and 4 were compared with the joint space narrowing (JSN) score in SHS. Multilevel mixed model statistics were applied to calculate the significance of the association between ΔJSW and ΔBMD over 1 year, and the JSW differences between damaged and undamaged joints as evaluated by the JSN. Based on 576 joints of 96 patients with eRA, a significant reduction from baseline to 1 year was observed in the JSW from 1.69 (±0.19) mm to 1.66 (±0.19) mm (p0) joints: 1.68 mm (95% CI 1.70 to 1.67) vs 1.54 mm (95% CI 1.63 to 1.46). Similarly the unadjusted multilevel model showed significant differences in JSW between undamaged (1.68 mm (95% CI 1.72 to 1.64)) and damaged joints (1.63 mm (95% CI 1.68 to 1.58)) (p=0.0048). This difference remained significant in the adjusted model: 1.66 mm (95% CI 1.70 to 1.61) vs 1.62 mm (95% CI 1.68 to 1.56) (p=0.042). To measure the JSW with this fully automated digital tool may be useful as a quick and observer-independent application for evaluating cartilage damage in eRA. NCT00764725.

  3. Fast charge digitizer and digital data acquisition system for measuring time varying radiation fields

    International Nuclear Information System (INIS)

    Lee, T.R.; Schneider, R.H.; Wyatt, J.L.

    1976-01-01

    A radiation measuring instrument including a fast charge digitizer and a digital data acquisition system has been developed. The fast charge digitizer includes a charge integrator connected to a conventional ionization chamber which generates an output current in proportion to ionizing radiation exposure rate. The charge integrator has an output connected to a comparator which is switched from a high state to a low state when the output of the integrator goes above the comparator threshold. The comparator output is connected to a bistable multivibrator consisting of two non-retriggerable one shot multivibrators connected in a feedback configuration. As long as the comparator output is in the low state, the bistable multivibrator generates a train of pluses which are fed back through an analog switch and a high megohm resistance to the input of the integrator. This feedback is negative and has the effect of removing the charge from the integrating capacitor, thus causing the integrator output eventually to drop below the comparator threshold. When this occurs the comparator output returns to the high state and the bistable multivibrator ceases to generate output pulses. An output terminal is connected between the bistable multivibrator and the analog switch and feeds a train of pulses proportional to the amount of charge generated by the multivibrator output voltage and the high megohm resistance to a counter connected to a random access memory device. The output pulses are counted for a predetermined time and then stored in one of the data locations of the random access memory device. The counter is then reset and a further predetermined sample period is counted. This continues until all of the locations in the random access memory device are filled and then the data is read from the random access memory device

  4. Low-cost digital counting interface for fermentation gas measurement

    Energy Technology Data Exchange (ETDEWEB)

    Erdman, M.D.; Deluiche, S.R.

    1985-05-01

    Laboratory- and pilot-scale volumetric measurement of fermentation gas can be readily determined with a standard wet-test gas meter. The initial cost of the meter, however, is quite prohibitive for experimental work and researchers have searched for other means of quantifying gas production. Techniques using calibrated floating gas holders, liquid displacement, flexible membranes, and conventional gas meters have been reported. Many of these methods lack a high degree of accuracy for small gas volumes. Residential gas meters such as those manufactured by Singer company, and others appear well suited for this application as long as a relatively dry gas is passed through the meter and a method is developed to subdivide the meter scale and record the results. The objective of this report was to construct a low cost, accurate, digital counting interface for concurrent operation with a low cost bellows-type gas meter. Although initially constructed for use in gas measurement studies, the interface can be used in other applications where digital output or computer interfacing are desired. 2 references.

  5. Measurements of granular flow dynamics with high speed digital images

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jingeol [Univ. of Florida, Gainesville, FL (United States)

    1994-01-01

    The flow of granular materials is common to many industrial processes. This dissertation suggests and validates image processing algorithms applied to high speed digital images to measure the dynamics (velocity, temperature and volume fraction) of dry granular solids flowing down an inclined chute under the action of gravity. Glass and acrylic particles have been used as granular solids in the experiment. One technique utilizes block matching for spatially averaged velocity measurements of the glass particles. This technique is compared with the velocity measurement using an optic probe which is a conventional granular flow velocity measurement device. The other technique for measuring the velocities of individual acrylic particles is developed with correspondence using a Hopfield network. This technique first locates the positions of particles with pattern recognition techniques, followed by a clustering technique, which produces point patterns. Also, several techniques are compared for particle recognition: synthetic discriminant function (SDF), minimum average correlation energy (MACE) filter, modified minimum average correlation energy (MMACE) filter and variance normalized correlation. The author proposes an MMACE filter which improves generalization of the MACE filter by adjusting the amount of averaged spectrum of training images in the spectrum whitening stages of the MACE filter. Variance normalized correlation is applied to measure the velocity and temperature of flowing glass particles down the inclined chute. The measurements are taken for the steady and wavy flow and qualitatively compared with a theoretical model of granular flow.

  6. Bilateral agreements

    International Nuclear Information System (INIS)

    Anon.

    2004-01-01

    The bilateral agreements concern Brazil with United States relative to the co operation in nuclear energy, Germany with Russian Federation relative to the elimination and disposal of nuclear weapons; The multilateral agreements concerns the signature of the Protocols to amend the Paris and Brussels Conventions, the multilateral nuclear environmental programme in the Russian Federation, the status of Conventions in the field of nuclear energy. (N.C.)

  7. Digitization

    DEFF Research Database (Denmark)

    Finnemann, Niels Ole

    2014-01-01

    what a concept of digital media might add to the understanding of processes of mediatization and what the concept of mediatization might add to the understanding of digital media. It is argued that digital media open an array of new trajectories in human communication, trajectories which were...

  8. Quality control measurements for digital x-ray detectors

    Energy Technology Data Exchange (ETDEWEB)

    Marshall, N W [Department of Radiology, University Hospitals Leuven, 49 Herenstraat, 3000 Leuven (Belgium); Mackenzie, A [National Co-ordinating Centre for the Physics of Mammography, Medical Physics, Level B, St Luke' s Wing, The Royal Surrey County Hospital NHS Trust, Egerton Road, Guildford, GU2 7XX (United Kingdom); Honey, I D, E-mail: nicholas.marshall@uz.kuleuven.ac.be [Department of Medical Physics, Floor 3, Henriette Raphael House, Guy' s and St Thomas' Hospital, London, SE1 9RT (United Kingdom)

    2011-02-21

    This paper describes a digital radiography (DR) quality control protocol for DR detectors from the forthcoming report from the Institute of Physics and Engineering in Medicine (IPEM). The protocol was applied to a group of six identical caesium iodide (CsI) digital x-ray detectors to assess reproducibility of methods, while four further detectors were assessed to examine the wider applicability. Twelve images with minimal spatial frequency processing are required, from which the detector response, lag, modulation transfer function (MTF), normalized noise power spectrum (NNPS) and threshold contrast-detail (c-d) detectability are calculated. The x-ray spectrum used was 70 kV and 1 mm added copper filtration, with a target detector air kerma of 2.5 {mu}Gy for the NNPS and c-d results. In order to compare detector performance with previous imaging technology, c-d data from four screen/film systems were also acquired, at a target optical density of 1.5 and an average detector air kerma of 2.56 {mu}Gy. The DR detector images were typically acquired in 20 min, with a further 45 min required for image transfer and analysis. The average spatial frequency for the 50% point of the MTF for six identical detectors was 1.29 mm{sup -1} {+-} 0.05 (3.9% coefficient of variation (cov)). The air kerma set for the six systems was 2.57 {mu}Gy {+-} 0.13 (5.0% cov) and the NNPS at this air kerma was 1.42 x 10{sup -5} mm{sup 2} (6.5% cov). The detective quantum efficiency (DQE) measured for the six identical detectors was 0.60 at 0.5 mm{sup -1}, with a maximum cov of 10% at 2.9 mm{sup -1}, while the average DQE was 0.56 at 0.5 mm{sup -1} for three CsI detectors from three different manufacturers. Comparable c-d performance was found for these detectors (5.9% cov) with an average threshold contrast of 0.46% for 11 mm circular discs. The average threshold contrast for the S/F systems was 0.70% at 11 mm, indicating superior imaging performance for the digital systems. The protocol was found

  9. Cherenkov luminescence measurements with digital silicon photomultipliers: a feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Ciarrocchi, Esther; Belcari, Nicola; Guerra, Alberto Del [Department of Physics, University of Pisa, Pisa (Italy); INFN, section of Pisa, Pisa (Italy); Cherry, Simon R. [Department of Biomedical Engineering, University of California, Davis, CA (United States); Lehnert, Adrienne; Hunter, William C. J.; McDougald, Wendy; Miyaoka, Robert S.; Kinahan, Paul E. [Department of Radiology, University of Washington, Seattle, WA (United States)

    2015-11-16

    A feasibility study was done to assess the capability of digital silicon photomultipliers to measure the Cherenkov luminescence emitted by a β source. Cherenkov luminescence imaging (CLI) is possible with a charge coupled device (CCD) based technology, but a stand-alone technique for quantitative activity measurements based on Cherenkov luminescence has not yet been developed. Silicon photomultipliers (SiPMs) are photon counting devices with a fast impulse response and can potentially be used to quantify β-emitting radiotracer distributions by CLI. In this study, a Philips digital photon counting (PDPC) silicon photomultiplier detector was evaluated for measuring Cherenkov luminescence. The PDPC detector is a matrix of avalanche photodiodes, which were read one at a time in a dark count map (DCM) measurement mode (much like a CCD). This reduces the device active area but allows the information from a single avalanche photodiode to be preserved, which is not possible with analog SiPMs. An algorithm to reject the noisiest photodiodes and to correct the measured count rate for the dark current was developed. The results show that, in DCM mode and at (10–13) °C, the PDPC has a dynamic response to different levels of Cherenkov luminescence emitted by a β source and transmitted through an opaque medium. This suggests the potential for this approach to provide quantitative activity measurements. Interestingly, the potential use of the PDPC in DCM mode for direct imaging of Cherenkov luminescence, as a opposed to a scalar measurement device, was also apparent. We showed that a PDPC tile in DCM mode is able to detect and image a β source through its Cherenkov radiation emission. The detector’s dynamic response to different levels of radiation suggests its potential quantitative capabilities, and the DCM mode allows imaging with a better spatial resolution than the conventional event-triggered mode. Finally, the same acquisition procedure and data processing could

  10. Cherenkov luminescence measurements with digital silicon photomultipliers: a feasibility study

    International Nuclear Information System (INIS)

    Ciarrocchi, Esther; Belcari, Nicola; Guerra, Alberto Del; Cherry, Simon R.; Lehnert, Adrienne; Hunter, William C. J.; McDougald, Wendy; Miyaoka, Robert S.; Kinahan, Paul E.

    2015-01-01

    A feasibility study was done to assess the capability of digital silicon photomultipliers to measure the Cherenkov luminescence emitted by a β source. Cherenkov luminescence imaging (CLI) is possible with a charge coupled device (CCD) based technology, but a stand-alone technique for quantitative activity measurements based on Cherenkov luminescence has not yet been developed. Silicon photomultipliers (SiPMs) are photon counting devices with a fast impulse response and can potentially be used to quantify β-emitting radiotracer distributions by CLI. In this study, a Philips digital photon counting (PDPC) silicon photomultiplier detector was evaluated for measuring Cherenkov luminescence. The PDPC detector is a matrix of avalanche photodiodes, which were read one at a time in a dark count map (DCM) measurement mode (much like a CCD). This reduces the device active area but allows the information from a single avalanche photodiode to be preserved, which is not possible with analog SiPMs. An algorithm to reject the noisiest photodiodes and to correct the measured count rate for the dark current was developed. The results show that, in DCM mode and at (10–13) °C, the PDPC has a dynamic response to different levels of Cherenkov luminescence emitted by a β source and transmitted through an opaque medium. This suggests the potential for this approach to provide quantitative activity measurements. Interestingly, the potential use of the PDPC in DCM mode for direct imaging of Cherenkov luminescence, as a opposed to a scalar measurement device, was also apparent. We showed that a PDPC tile in DCM mode is able to detect and image a β source through its Cherenkov radiation emission. The detector’s dynamic response to different levels of radiation suggests its potential quantitative capabilities, and the DCM mode allows imaging with a better spatial resolution than the conventional event-triggered mode. Finally, the same acquisition procedure and data processing could

  11. Reliability-guided digital image correlation for image deformation measurement

    International Nuclear Information System (INIS)

    Pan Bing

    2009-01-01

    A universally applicable reliability-guided digital image correlation (DIC) method is proposed for reliable image deformation measurement. The zero-mean normalized cross correlation (ZNCC) coefficient is used to identify the reliability of the point computed. The correlation calculation begins with a seed point and is then guided by the ZNCC coefficient. That means the neighbors of the point with the highest ZNCC coefficient in a queue for computed points will be processed first. Thus the calculation path is always along the most reliable direction, and possible error propagation of the conventional DIC method can be avoided. The proposed novel DIC method is universally applicable to the images with shadows, discontinuous areas, and deformation discontinuity. Two image pairs were used to evaluate the performance of the proposed technique, and the successful results clearly demonstrate its robustness and effectiveness

  12. ADC border effect and suppression of quantization error in the digital dynamic measurement

    International Nuclear Information System (INIS)

    Bai Li-Na; Liu Hai-Dong; Zhou Wei; Zhai Hong-Qi; Cui Zhen-Jian; Zhao Ming-Ying; Gu Xiao-Qian; Liu Bei-Ling; Huang Li-Bei; Zhang Yong

    2017-01-01

    The digital measurement and processing is an important direction in the measurement and control field. The quantization error widely existing in the digital processing is always the decisive factor that restricts the development and applications of the digital technology. In this paper, we find that the stability of the digital quantization system is obviously better than the quantization resolution. The application of a border effect in the digital quantization can greatly improve the accuracy of digital processing. Its effective precision has nothing to do with the number of quantization bits, which is only related to the stability of the quantization system. The high precision measurement results obtained in the low level quantization system with high sampling rate have an important application value for the progress in the digital measurement and processing field. (paper)

  13. Measurement of rabbit eardrum vibration through stroboscopic digital holography

    Energy Technology Data Exchange (ETDEWEB)

    De Greef, Daniël; Dirckx, Joris J. J. [University of Antwerp, Laboratory of BioMedical Physics, Groenenborgerlaan 171, B-2020 Antwerp (Belgium)

    2014-05-27

    In this work, we present a setup for high-power single shot stroboscopic digital holography and demonstrate it in an application on rabbit eardrum vibration measurement. The setup is able to make full-field time-resolved measurements of vibrating surfaces with a precision in the nanometer range in a broad frequency range. The height displacement of the measured object is visualized over the entire surface as a function of time. Vibration magnitude and phase maps can be extracted from these data, the latter proving to be very useful to reveal phase delays across the surface. Such deviations from modal motion indicate energy losses due to internal damping, in contrast to purely elastic mechanics. This is of great interest in middle ear mechanics and finite element modelling. In our setup, short laser pulses are fired at selected instants within the surface vibration period and are recorded by a CCD camera. The timing of the pulses and the exposure of the camera are synchronized to the vibration phase by a microprocessor. The high-power frequency-doubled Nd:YAG laser produces pulses containing up to 5 mJ of energy, which is amply sufficient to record single-shot holograms. As the laser pulse length is 8 ns and the smallest time step of the trigger electronics is 1 μs, vibration measurements of frequencies up to 250 kHz are achievable through this method, provided that the maximum vibration amplitude exceeds a few nanometers. In our application, middle ear mechanics, measuring frequencies extend from 5 Hz to 20 kHz. The experimental setup will be presented, as well as results of measurements on a stretched circular rubber membrane and a rabbit's eardrum. Two of the challenges when measuring biological tissues, such as the eardrum, are low reflectivity and fast dehydration. To increase reflectivity, a coating is applied and to counteract the undesirable effects of tissue dehydration, the measurement setup and software have been optimized for speed without

  14. Academic Digital Library Construction Evaluation: Measures and Approaches

    OpenAIRE

    Wang , Qiyun

    2008-01-01

    Through review norms, standards and practice related to academic digital library construction evaluation at home and abroad, on the basis of investigation and study on the digital library evaluation at home and abroad, for status quo of the academic digital library construction, using qualitative analysis and quantitative analysis method, with methods and indicators for the traditional library evaluation system as a reference coordinates, put forward a comprehensive evaluation index system of...

  15. From digital earth to digital neighbourhood: A study of subjective measures of walkability attributes in objectively assessed digital neighbourhood

    International Nuclear Information System (INIS)

    Qureshi, S; Ho, C S

    2014-01-01

    According to IEA report (2011), about 23% of the World's CO 2 emissions result from transport and this is one of the few areas where emissions are still rapidly increasing. The use of private vehicles is one of the principle contributors to green house gas emissions from transport sector. Therefore this paper focuses on the shift to more sustainable and low carbon forms of transportation mode such as walking. Neighbourhood built environment attributes may influence walkability. For this study, the author used a modified version of the ''Neighbourhood Environment Walkability Scale'' to make comparison between respondents' perceptions regarding attributes of two neighborhoods of Putrajaya. The 21st Century really needs planners to use the Digital Earth Concept, to go from global to regional to national to very local issues, using integrated, advanced technologies such as earth observation, GIS, virtual reality, etc. For this research, two (2) neighborhoods of different densities (High and Low density) were selected. A sample total of 381(195 and 186) between 7 to 65 years old participants were selected For subjective measures we used 54 questions questionnaire survey where as for the objective measures we used desktop 9.3 version of Arc GIS soft ware. Our results shows that respondents who reside in high-walkable neighbourhood precinct 9 in Putrajaya rated factors such as residential density, land use mix, proximity to destination and street connectivity, consistently higher then did respondents of the low walkable neighbourhood precinct 8 in Putrajaya

  16. The application of the bilateral collimator to parasternal lymphoscintigraphy: a new method to measure the depth of the lymph node

    International Nuclear Information System (INIS)

    Ohtake, E.; Toyama, H.; Iio, M.; Noguchi, M.; Kawaguchi, S.; Murata, H.; Chiba, K.; Yamada, H.

    1980-01-01

    The bilateral collimator has been widely adopted for obtaining two simultaneous views of the heart in nuclear cardiology. As an additional useful clinical application of the bilateral collimator, it has been used for parasternal lymphoscintigraphy. Lymphography with a contrast medium for the parasternal lymphatics is technically very difficult and the radionuclide method is adopted. Lymphoscintigraphy has been used in order to determine the existence of malignant invasion to the lymph nodes, and also to find the depth of the lymph node as a guide to operation and radiation therapy of the nodes. (author)

  17. The development of digital oscilloscope control software in nuclear measurement

    International Nuclear Information System (INIS)

    Pu Minghui; Tian Geng; Li Xianyou

    2004-01-01

    This essay presents the development of an all-purpose digital oscilloscope control software on Windows 95/98 OS. The background and method are discussed in detail, together with the function and characteristics of the software. With the use of this software, a single PC can control several digital oscilloscopes. Solution of main problems encountered in the development is also discussed. (authors)

  18. Procedure to determine the two channel timing measurement accuracy and precision of a digital oscilloscope

    International Nuclear Information System (INIS)

    Johnson, M.; Matulik, M.

    1994-01-01

    The digital oscilloscope allows one to make numerous timing measurements, but just how good are those measurements? This document describes a procedure which can be used to determine the accuracy and precision to which a digital oscilloscope can make various two channel timing measurements

  19. [Reliability study in the measurement of the cusp inclination angle of a chairside digital model].

    Science.gov (United States)

    Xinggang, Liu; Xiaoxian, Chen

    2018-02-01

    This study aims to evaluate the reliability of the software Picpick in the measurement of the cusp inclination angle of a digital model. Twenty-one trimmed models were used as experimental objects. The chairside digital impression was then used for the acquisition of 3D digital models, and the software Picpick was employed for the measurement of the cusp inclination of these models. The measurements were repeated three times, and the results were compared with a gold standard, which was a manually measured experimental model cusp angle. The intraclass correlation coefficient (ICC) was calculated. The paired t test value of the two measurement methods was 0.91. The ICCs between the two measurement methods and three repeated measurements were greater than 0.9. The digital model achieved a smaller coefficient of variation (9.9%). The software Picpick is reliable in measuring the cusp inclination of a digital model.

  20. Objective and subjective measures of simultaneous vs sequential bilateral cochlear implants in adults : A randomized clinical trial

    NARCIS (Netherlands)

    Kraaijenga, Véronique J.C.; Ramakers, Geerte G.J.; Smulders, Yvette E.; Van Zon, Alice; Stegeman, Inge; Smit, Adriana L.; Stokroos, Robert J.; Hendrice, Nadia; Free, Rolien H.; Maat, Bert; Frijns, Johan H M; Briaire, Jeroen J; Mylanus, Emmanuel A M; Huinck, Wendy J.; van Zanten, Gijsbert A.; Grolman, Wilko

    2017-01-01

    IMPORTANCE: To date, no randomized clinical trial on the comparison between simultaneous and sequential bilateral cochlear implants (BiCIs) has been performed.  OBJECTIVE: To investigate the hearing capabilities and the self-reported benefits of simultaneous BiCIs compared with those of sequential

  1. Objective and Subjective Measures of Simultaneous vs Sequential Bilateral Cochlear Implants in Adults: A Randomized Clinical Trial

    NARCIS (Netherlands)

    Kraaijenga, V.J.; Ramakers, G.G.; Smulders, Y.E.; Zon, A. van; Stegeman, I.; Smit, A.L.; Stokroos, R.J.; Hendrice, N.; Free, R.H.; Maat, B.; Frijns, J.H.; Briaire, J.J.; Mylanus, E.A.M.; Huinck, W.J.; Zanten, G.A.; Grolman, W.

    2017-01-01

    Importance: To date, no randomized clinical trial on the comparison between simultaneous and sequential bilateral cochlear implants (BiCIs) has been performed. Objective: To investigate the hearing capabilities and the self-reported benefits of simultaneous BiCIs compared with those of sequential

  2. Full-Field Indentation Damage Measurement Using Digital Image Correlation

    Directory of Open Access Journals (Sweden)

    Elías López-Alba

    2017-07-01

    Full Text Available A novel approach based on full-field indentation measurements to characterize and quantify the effect of contact in thin plates is presented. The proposed method has been employed to evaluate the indentation damage generated in the presence of bending deformation, resulting from the contact between a thin plate and a rigid sphere. For this purpose, the 3D Digital Image Correlation (3D-DIC technique has been adopted to quantify the out of plane displacements at the back face of the plate. Tests were conducted using aluminum thin plates and a rigid bearing sphere to evaluate the influence of the thickness and the material behavior during contact. Information provided by the 3D-DIC technique has been employed to perform an indirect measurement of the contact area during the loading and unloading path of the test. A symmetrical distribution in the contact damage region due to the symmetry of the indenter was always observed. In the case of aluminum plates, the presence of a high level of plasticity caused shearing deformation as the load increased. Results show the full-field contact damage area for different plates’ thicknesses at different loads. The contact damage region was bigger when the thickness of the specimen increased, and therefore, bending deformation was reduced. With the proposed approach, the elastic recovery at the contact location was quantified during the unloading, as well as the remaining permanent indentation damage after releasing the load. Results show the information obtained by full-field measurements at the contact location during the test, which implies a substantial improvement compared with pointwise techniques.

  3. Digital video image processing applications to two phase flow measurements

    International Nuclear Information System (INIS)

    Biscos, Y.; Bismes, F.; Hebrard, P.; Lavergne, G.

    1987-01-01

    Liquid spraying is common in various fields (combustion, cooling of hot surfaces, spray drying,...). For two phase flows modeling, it is necessary to test elementary laws (vaporizing drops, equation of motion of drops or bubbles, heat transfer..). For example, the knowledge of the laws related to the behavior of vaporizing liquid drop in a hot airstream and impinging drops on a hot surface is important for two phase flow modeling. In order to test these different laws in elementary cases, the authors developed different measurement techniques, associating video and microcomputers. The test section (built in perpex or glass) is illuminated with a thin sheet of light generated by a 15mW He-Ne laser and appropriate optical arrangement. Drops, bubbles or liquid film are observed at right angle by a video camera synchronised with a microcomputer either directly or with an optical device (lens, telescope, microscope) providing sufficient magnification. Digitizing the video picture in real time associated with an appropriate numerical treatment allows to obtain, in a non interfering way, a lot of informations relative to the pulverisation and the vaporization as function of space and time (drop size distribution; Sauter mean diameter as function of main flow parameters: air velocity, surface tension, temperature; isoconcentration curves, size evolution relative to vaporizing drops, film thickness evolution spreading on a hot surface...)

  4. Correlation and agreement of a digital and conventional method to measure arch parameters.

    Science.gov (United States)

    Nawi, Nes; Mohamed, Alizae Marny; Marizan Nor, Murshida; Ashar, Nor Atika

    2018-01-01

    The aim of the present study was to determine the overall reliability and validity of arch parameters measured digitally compared to conventional measurement. A sample of 111 plaster study models of Down syndrome (DS) patients were digitized using a blue light three-dimensional (3D) scanner. Digital and manual measurements of defined parameters were performed using Geomagic analysis software (Geomagic Studio 2014 software, 3D Systems, Rock Hill, SC, USA) on digital models and with a digital calliper (Tuten, Germany) on plaster study models. Both measurements were repeated twice to validate the intraexaminer reliability based on intraclass correlation coefficients (ICCs) using the independent t test and Pearson's correlation, respectively. The Bland-Altman method of analysis was used to evaluate the agreement of the measurement between the digital and plaster models. No statistically significant differences (p > 0.05) were found between the manual and digital methods when measuring the arch width, arch length, and space analysis. In addition, all parameters showed a significant correlation coefficient (r ≥ 0.972; p digital and manual measurements. Furthermore, a positive agreement between digital and manual measurements of the arch width (90-96%), arch length and space analysis (95-99%) were also distinguished using the Bland-Altman method. These results demonstrate that 3D blue light scanning and measurement software are able to precisely produce 3D digital model and measure arch width, arch length, and space analysis. The 3D digital model is valid to be used in various clinical applications.

  5. DIGITAL

    Data.gov (United States)

    Federal Emergency Management Agency, Department of Homeland Security — The Digital Flood Insurance Rate Map (DFIRM) Database depicts flood risk information and supporting data used to develop the risk data. The primary risk...

  6. Bilateral agreements

    International Nuclear Information System (INIS)

    1998-01-01

    Ten bilateral agreements are presented. These are: 1) Co-operation agreement relating to the peaceful uses of nuclear energy between Argentina and EURATOM (1996); 2) Agreement on co-operation in the peaceful uses of nuclear energy between Argentina and Greece (1997); 3) Implementing arrangement for technical exchange and co-operation in the area of peaceful uses of nuclear energy between Argentina and the United States (1997); 4) Agreement concerning co-operation in nuclear science and technology between Australia and Indonesia (1997); 5) Implementation of the 1985 Agreement for co-operation concerning the peaceful uses of nuclear energy between the People's Republic of China and the United States (1998); 6) Protocol of co-operation between France and Lithuania (1997); 7) Agreement on co-operation in energy research, science and technology, and development between Germany and the United States (1998); 8) Agreement on early notification of a nuclear accident and exchange of information on nuclear facilities between Greece and Romania (1997); 9) Agreement on early notification of nuclear accidents and co-operation in the field of nuclear safety between Hungary and the Ukraine (1997); 10) Agreement in the field of radioactive waste management between Switzerland and the United States (1997). (K.A.)

  7. Digital Measuring Devices Used for Injector Hydraulic Test

    Directory of Open Access Journals (Sweden)

    S. N. Leontiev

    2015-01-01

    Full Text Available To ensure a high specific impulse of the LRE (liquid-propellant engine chamber it is necessary to have optimally organized combustion of the fuel components. This can be ensured by choosing the optimum geometry of gas-dynamic contour of the LRE combustor, as well as by improving the sputtering processes and mixing the fuel components, for example, by selection of the optimum type, characteristics, and location of injectors on the mixing unit of the chamber.These particular reasons arise the interest in the injector characteristics in terms of science, and technological aspects determine the need for control of underlying design parameters in their manufacture.The objective of this work is to give an experimental justification on used digital measurement instrumentation and research the hydraulic characteristics of injectors.To determine injector parameters most widely were used the units with sectional collectors. A technique to control injector parameters using the sectional collectors involves spraying the liquid by injector at a given pressure drop on it for a certain time (the longer, the higher the accuracy and reliability of the results and then determining the amount of liquid in each section to calculate the required parameters of injector.In this work the liquid flow through the injector was determined by high-precision flowmeters FLONET FN2024.1 of electromagnetic type, which have very high metrological characteristics, in particular a flow rate error does not exceed 0.5% in a range of water flow from Qmin= 0.0028 l/s to Qmax Qmax = 0.28 l/s. To determine the coefficient of uneven spray were used differential pressure sensors DMD 331-ASLX of company "DB Sensors RUS", which have an error of 0.075% with a range of differential pressure 0 ... 5 kPa. Measuring complex MIC-200 of company "NPP Measure" and WinPos software for processing array information provided entry, recording, and processing of all the data of the experiment.In this

  8. Creativity in the Age of Technology: Measuring the Digital Creativity of Millennials

    Science.gov (United States)

    Hoffmann, Jessica; Ivcevic, Zorana; Brackett, Marc

    2016-01-01

    Digital technology and its many uses form an emerging domain of creative expression for adolescents and young adults. To date, measures of self-reported creative behavior cover more traditional forms of creativity, including visual art, music, or writing, but do not include creativity in the digital domain. This article introduces a new measure,…

  9. Objective and Subjective Measures of Simultaneous vs Sequential Bilateral Cochlear Implants in Adults: A Randomized Clinical Trial.

    Science.gov (United States)

    Kraaijenga, Véronique J C; Ramakers, Geerte G J; Smulders, Yvette E; van Zon, Alice; Stegeman, Inge; Smit, Adriana L; Stokroos, Robert J; Hendrice, Nadia; Free, Rolien H; Maat, Bert; Frijns, Johan H M; Briaire, Jeroen J; Mylanus, E A M; Huinck, Wendy J; Van Zanten, Gijsbert A; Grolman, Wilko

    2017-09-01

    To date, no randomized clinical trial on the comparison between simultaneous and sequential bilateral cochlear implants (BiCIs) has been performed. To investigate the hearing capabilities and the self-reported benefits of simultaneous BiCIs compared with those of sequential BiCIs. A multicenter randomized clinical trial was conducted between January 12, 2010, and September 2, 2012, at 5 tertiary referral centers among 40 participants eligible for BiCIs. Main inclusion criteria were postlingual severe to profound hearing loss, age 18 to 70 years, and a maximum duration of 10 years without hearing aid use in both ears. Data analysis was conducted from May 24 to June 12, 2016. The simultaneous BiCI group received 2 cochlear implants during 1 surgical procedure. The sequential BiCI group received 2 cochlear implants with an interval of 2 years between implants. First, the results 1 year after receiving simultaneous BiCIs were compared with the results 1 year after receiving sequential BiCIs. Second, the results of 3 years of follow-up for both groups were compared separately. The primary outcome measure was speech intelligibility in noise from straight ahead. Secondary outcome measures were speech intelligibility in noise from spatially separated sources, speech intelligibility in silence, localization capabilities, and self-reported benefits assessed with various hearing and quality of life questionnaires. Nineteen participants were randomized to receive simultaneous BiCIs (11 women and 8 men; median age, 52 years [interquartile range, 36-63 years]), and another 19 participants were randomized to undergo sequential BiCIs (8 women and 11 men; median age, 54 years [interquartile range, 43-64 years]). Three patients did not receive a second cochlear implant and were unavailable for follow-up. Comparable results were found 1 year after simultaneous or sequential BiCIs for speech intelligibility in noise from straight ahead (difference, 0.9 dB [95% CI, -3.1 to 4.4 dB]) and

  10. Digital instantaneous frequency measurement technique utilising high-speed ADC’s and FPGA’s

    CSIR Research Space (South Africa)

    Herselman, PL

    2006-02-27

    Full Text Available This paper presents the Digital Instantaneous Frequency Measurement (DIFM) technique, which can measure the carrier frequency of a received waveform within a fraction of a microsecond. The resulting frequency range, resolution and accuracy...

  11. Reconfigurable digital receiver design and application for instantaneous polarimetric measurement

    NARCIS (Netherlands)

    Wang, Z.; Krasnov, O.A.; Babur, G.P.; Ligthart, L.P.; Van der Zwan, F.

    2011-01-01

    This paper presents the development of a reconfigurable receiver to undertake challenging signal processing tasks for a novel polarimetric radar system. The field-programmable gate arrays (FPGAs)-based digital receiver samples incoming signals at intermediate frequency (IF) and processes signals

  12. Comparison of conventional study model measurements and 3D digital study model measurements from laser scanned dental impressions

    Science.gov (United States)

    Nugrahani, F.; Jazaldi, F.; Noerhadi, N. A. I.

    2017-08-01

    The field of orthodontics is always evolving,and this includes the use of innovative technology. One type of orthodontic technology is the development of three-dimensional (3D) digital study models that replace conventional study models made by stone. This study aims to compare the mesio-distal teeth width, intercanine width, and intermolar width measurements between a 3D digital study model and a conventional study model. Twelve sets of upper arch dental impressions were taken from subjects with non-crowding teeth. The impressions were taken twice, once with alginate and once with polivinylsiloxane. The alginate impressions used in the conventional study model and the polivinylsiloxane impressions were scanned to obtain the 3D digital study model. Scanning was performed using a laser triangulation scanner device assembled by the School of Electrical Engineering and Informatics at the Institut Teknologi Bandung and David Laser Scan software. For the conventional model, themesio-distal width, intercanine width, and intermolar width were measured using digital calipers; in the 3D digital study model they were measured using software. There were no significant differences between the mesio-distal width, intercanine width, and intermolar width measurments between the conventional and 3D digital study models (p>0.05). Thus, measurements using 3D digital study models are as accurate as those obtained from conventional study models

  13. Measurement Invariance of the Digital Natives Assessment Scale across Gender in a Sample of Turkish University Students

    Science.gov (United States)

    Ursavas, Ömer Faruk; Kabakçi Yurdakul, Isil; Türk, Mesut; Mcilroy, David

    2016-01-01

    With reference to the digital natives' debate, there is a gap on digital natives' characteristics. To fill this gap, the Digital Natives Assessment Scale was developed to measure students' assessment of the degree to which they perceived themselves to possess the attributes of digital natives. The scale was developed within the Turkish language…

  14. Pelvic measurements by means of digital radiography (CT topogram)

    Energy Technology Data Exchange (ETDEWEB)

    Reisner, K; Fettig, O; Bartscher, K H; Knappschneider, U

    1985-05-01

    Radiographic examination during pregnancy and pelvimetry before pregnancy are still required for particular indications. The use of digital radiography (lateral topogram on CT) reduces the radiation dose to the foetus and ovaries by a factor of 10 to 100, as compared with conventional pelvimetry, as described by Guthmann. The accuracy of this method is satisfactory, the technique is simple, it is rapid and is easy for the patient, particularly for pregnant women. As long as pelvimetry is not possible without ionising radiation, we consider pelvimetry with digital radiography, when strictly indicated, to be acceptable. In order to determine the transverse diameter of the pelvis, a single additional CT cut through the narrowest part of the pelvis is suggested.

  15. Measuring the Digital Divide with PingER

    Energy Technology Data Exchange (ETDEWEB)

    Cottrell, L.

    2003-10-01

    We introduce the PingER project/toolkit and show its relevance to monitoring sites in developing countries. We then show results from PingER that illustrate the extent of the Digital Divide in terms of Internet performance between developed and developing regions, which developing regions are catching up, keeping up, or falling behind and the magnitude of the differences in performance between developed regions and developing regions.

  16. Digital spectrometer for coincidence measurement of Doppler broadening of positron annihilation radiation

    International Nuclear Information System (INIS)

    Cizek, J.; Vlcek, M.; Prochazka, I.

    2010-01-01

    High-resolution digital coincidence Doppler broadening spectrometer equipped with two high-purity Ge detectors and two-channel 12-bit fast digitizer was developed and tested in this work. Two configurations were compared: (i) semi-digital setup which uses active analogue shaping of detector pulses prior to digitization to improve signal-to-noise ratio, and (ii) pure-digital setup which samples detector pulses directly. Software procedure developed for analysis of sampled waveforms, i.e. precise determination of energy of detected photon and rejection of distorted pulses, is described. Performance of digital coincidence spectrometer was compared with traditional analogue setup connected to the same detectors. It was found that digital spectrometer enables to achieve better energy resolution than in traditional analogue setup. Moreover, in digital configuration one has better control over shape of the signal. This allows efficient elimination of undesired distorted or damaged waveforms and to obtain spectrum of better clarity. The superior parameters of new digital coincidence Doppler broadening spectrometer are demonstrated by benchmark measurements of well defined Fe and Al specimens and also by the detection of rare annihilation in flight events.

  17. Digital Earth Watch And Picture Post Network: Measuring The Environment Through Digital Images

    Science.gov (United States)

    Schloss, A. L.; Beaudry, J.; Carrera, F.; Pickle, J.

    2010-12-01

    Digital Earth Watch (DEW) involves individuals, schools, organizations and communities in a systematic monitoring project of their local environment, especially vegetation health. The program offers people the means to join the Picture Post network and to study and analyze their own findings using DEW software. A Picture Post is an easy-to-use and inexpensive platform for repeatedly taking digital photographs as a standardized set of images of the entire 360 ° landscape, which then can be shared over the Internet on the Picture Post website. This simple concept has the potential to create a wealth of information and data on changing environmental conditions, which is important for a society grappling with the effects of environmental change. Picture Post participants study change over time in their local area, compare digital images with NASA satellite imagery and contribute towards improving their own communities. A key message in DEW is that although plants are dynamic and respond continuously to their environment, they do so either on a time-scale that most people don't notice or with a subtlety our senses can't detect. DEW has created simple tools for monitoring vegetation as a means towards understanding the connection between global climate change and local effects. Picture Posts may be added by anyone interested in monitoring a particular location. The value of a Picture Post is in the commitment of participants to take repeated photographs - monthly, weekly, or even daily - to build up a long-term record over many years. DEW is being developed by a collaborative effort led by the University of New Hampshire with the Federation of Earth Science Information Partners, the University of Southern Maine, and Worcester Polytechnic Institute. This poster will show examples of picture posts and data that can be collected and will describe our soon-to-be-released “ virtual ” picture post cell phone app. The Picture Post network is new and we invite individuals

  18. Apparent diffusion coefficient measurements of bilateral kidneys at 3 T MRI: Effects of age, gender, and laterality in healthy adults

    International Nuclear Information System (INIS)

    Suo, S.-T.; Cao, M.-Q.; Ding, Y.-Z.; Yao, Q.-Y.; Wu, G.-Y.; Xu, J.-R.

    2014-01-01

    Aim: To investigate the effects of age and gender on apparent diffusion coefficient (ADC) measurements of bilateral kidneys at 3 T MRI, and compare the ADC values of left and right kidneys. Materials and methods: In all, 137 healthy participants (mean age 42.8 ± 14.7 years; age range 16–75 years) comprising 68 male and 69 female participants were enrolled. Three Tesla echo-planar diffusion-weighted imaging (DWI) of bilateral kidneys was performed and ADC values were measured in the cortex, medulla, and whole parenchyma. Pearson correlation analysis and linear regression were performed to determine the associations between the ADC values in each region and age. Effects of age and gender on ADC values were analysed using two-factor analysis of variance (ANOVA). The paired-samples t-test was established to compare the ADC values between left and right kidneys. Results: ADC values were significantly higher in the young group (≤50 years) than in the old group (>50 years), and correlated inversely with the age in all regions. Male participants had higher ADC values than female participants in all regions except left medulla. Two-factor ANOVA of age × gender showed no significant interactions between the variables age and gender were found. No significant differences in ADC values between left and right kidneys were observed. Conclusion: Renal ADC values are age- and gender-dependent, and show no significant difference between left and right kidneys. Age- and gender-related effects should be taken into consideration in future renal DWI studies when using normal ADC values from health controls. - Highlights: • Renal apparent diffusion coefficient (ADC) values decrease with ageing. • Men tend to have higher renal ADC values than women. • Bilateral kidneys seem to have no significantly different ADC values

  19. JMorph: Software for performing rapid morphometric measurements on digital images of fossil assemblages

    Science.gov (United States)

    Lelièvre, Peter G.; Grey, Melissa

    2017-08-01

    Quantitative morphometric analyses of form are widely used in palaeontology, especially for taxonomic and evolutionary research. These analyses can involve several measurements performed on hundreds or even thousands of samples. Performing measurements of size and shape on large assemblages of macro- or microfossil samples is generally infeasible or impossible with traditional instruments such as vernier calipers. Instead, digital image processing software is required to perform measurements via suitable digital images of samples. Many software packages exist for morphometric analyses but there is not much available for the integral stage of data collection, particularly for the measurement of the outlines of samples. Some software exists to automatically detect the outline of a fossil sample from a digital image. However, automatic outline detection methods may perform inadequately when samples have incomplete outlines or images contain poor contrast between the sample and staging background. Hence, a manual digitization approach may be the only option. We are not aware of any software packages that are designed specifically for efficient digital measurement of fossil assemblages with numerous samples, especially for the purposes of manual outline analysis. Throughout several previous studies, we have developed a new software tool, JMorph, that is custom-built for that task. JMorph provides the means to perform many different types of measurements, which we describe in this manuscript. We focus on JMorph's ability to rapidly and accurately digitize the outlines of fossils. JMorph is freely available from the authors.

  20. Digit Span as a measure of everyday attention: a study of ecological validity.

    Science.gov (United States)

    Groth-Marnat, Gary; Baker, Sonya

    2003-12-01

    This study investigated the effectiveness of the WAIS-III Digit Span subtest to predict the everyday attention of 75 participants with heterogeneous neurological conditions who were administered the Digit Span subtest as well as the ecologically valid Test of Everyday Attention. In addition, the more visually oriented Picture Completion subtest along with the verbally loaded National Adult Reading Test were administered. Analysis indicated that, although Digit Span was a weak but statistically significant predictor of attentional ability (accounting for 12.7% of the unique variance). Picture Completion was a somewhat stronger predictor (accounting for 19% of the unique variance). The weak association of Digit Span and the Test of Everyday Attention, along with the finding that Picture Completion was a better predictor of performance on the Test of Everyday Attention, question the clinical utility of using Digit Span as a measure of everyday attention.

  1. Trajectory and velocity measurement of a particle in spray by digital holography

    Energy Technology Data Exchange (ETDEWEB)

    Lue Qieni; Chen Yiliang; Yuan Rui; Ge Baozhen; Gao Yan; Zhang Yimo

    2009-12-20

    We present a method for the trajectory and the velocity measurement of a particle in spray by digital holography. Based on multiple exposure digital in-line holography, a sequence of digital holograms of a dynamic spray particle field at different times are recorded with a CW laser and a high-speed CCD. The time evolution of the serial positions of particles, i.e., the motion trajectories of the particles, is obtained by numerically reconstructing the synthetic hologram of a sequence of digital holograms. The center coordinate (x,y) of each particle image can be extracted using a Hough transform and subpixel precision computing, and the velocity of an individual particle can also be obtained, which is then applied to measuring the velocity of diesel spray and alcohol spray. The research shows that the method presented in this paper for measuring spray field is feasible.

  2. [Reconstruction and measurement of a digital dental model using grating projection and reverse engineering].

    Science.gov (United States)

    Zhenzhen, Wang; Yi, Lu; Jun, Song; Jun, Chen; Qin, Zhou

    2015-02-01

    This work lays the foundation for establishing a digital model database with normal occlusion. A digital dental cast is acquired through grating projection, and model features are measured through reverse engineering. The grating projection system controlled by a computer was projected onto the surface of a normal dental model. Three-dimensional contour data were obtained through multi-angle shooting. A three-dimensional model was constructed, and the model features were analyzed by using reverse engineering. The digital model was compared with the plaster model to determine the accuracy of the measurement system. The structure of three-dimensional reconstruction model was clear. The digital models of two measurements exhibited no significant difference (P > 0.05). When digital and plaster models were measured, we found that the crown length and arch width were not statistically different (P > 0.05), whereas the difference between the crown width and arch length was statistically significant (P model by using the grating projection technique and reverse engineering can be used for dental model measurement in clinic al and scientific research and can provide a scientific method for establishing a digital model database with normal occlusion.

  3. Kalman filtering techniques for reducing variance of digital speckle displacement measurement noise

    Institute of Scientific and Technical Information of China (English)

    Donghui Li; Li Guo

    2006-01-01

    @@ Target dynamics are assumed to be known in measuring digital speckle displacement. Use is made of a simple measurement equation, where measurement noise represents the effect of disturbances introduced in measurement process. From these assumptions, Kalman filter can be designed to reduce variance of measurement noise. An optical and analysis system was set up, by which object motion with constant displacement and constant velocity is experimented with to verify validity of Kalman filtering techniques for reduction of measurement noise variance.

  4. Comparison of root canal lathing measurement by conventional and digital radiology

    International Nuclear Information System (INIS)

    Mitrova, N.; Slavik, J.; Cecetkova, A.; Jenca, A.; Hanusinova, V.; Ondrasovicova, J.

    2006-01-01

    A correct working length is a critical factor within the endodontic treatment. The length of the root canal can be measured by different methods. The aim of this study was to compare methods used for measuring the length of root canals using conventional and digital radiology. The measurement was provided in both - in vitro and in vivo conditions. (authors)

  5. Differences in Measuring Market Risk in Four Subsectors of the Digital Economy

    OpenAIRE

    Sonia Benito; Rebeca de Juan; Ricardo Gómez; Francisco Mochón

    2015-01-01

    This paper defends the wisdom of not considering the Digital Economy to be one homogeneous sector. Our hypothesis is that it is best to consider it the result of adding four different subsectors. We test whether indeed the economic and financial performance of a portfolio of listed companies in each of the four subsectors presents relevant differences. We use the value at risk measure to estimate market risk of the four subsectors of the digital economy. The riskiest subsector is Mobile/Inter...

  6. Digital DC beam current measurement on SSRF storage ring

    International Nuclear Information System (INIS)

    Xiong Liang; Yin Chongxian; Liu Ming; Chen Jianfeng

    2011-01-01

    Both DC current transformer (DCCT) and integrating current transformer (ICT) can be used in DC beam current measurement. The ICT has strong capability of resisting electromagnetic interference, but its measurement accuracy cannot satisfy the DC beam current measurement requirement when using traditional high speed A/D. With high resolution A/D and equivalent sampling system, DC beam current measuring system based on ICT can reach high accuracy compared with DCCT system. In this paper, the ICT-based DC beam current measurement, equivalent sampling method and testing results at Shanghai Synchrotron Radiation Facility(SSRF) is described. (authors)

  7. Accuracy of a digital weight scale relative to the nintendo wii in measuring limb load asymmetry.

    Science.gov (United States)

    Kumar, Ns Senthil; Omar, Baharudin; Joseph, Leonard H; Hamdan, Nor; Htwe, Ohnmar; Hamidun, Nursalbiyah

    2014-08-01

    [Purpose] The aim of the present study was to investigate the accuracy of a digital weight scale relative to the Wii in limb loading measurement during static standing. [Methods] This was a cross-sectional study conducted at a public university teaching hospital. The sample consisted of 24 participants (12 with osteoarthritis and 12 healthy) recruited through convenient sampling. Limb loading measurements were obtained using a digital weight scale and the Nintendo Wii in static standing with three trials under an eyes-open condition. The limb load asymmetry was computed as the symmetry index. [Results] The accuracy of measurement with the digital weight scale relative to the Nintendo Wii was analyzed using the receiver operating characteristic (ROC) curve and Kolmogorov-Smirnov test (K-S test). The area under the ROC curve was found to be 0.67. Logistic regression confirmed the validity of digital weight scale relative to the Nintendo Wii. The D statistics value from the K-S test was found to be 0.16, which confirmed that there was no significant difference in measurement between the equipment. [Conclusion] The digital weight scale is an accurate tool for measuring limb load asymmetry. The low price, easy availability, and maneuverability make it a good potential tool in clinical settings for measuring limb load asymmetry.

  8. Parameters-adjustable front-end controller in digital nuclear measurement system

    International Nuclear Information System (INIS)

    Hao Dejian; Zhang Ruanyu; Yan Yangyang; Wang Peng; Tang Changjian

    2013-01-01

    Background: One digitizer is used to implement a digital nuclear measurement for the acquisition of nuclear information. Purpose: A principle and method of a parameter-adjustable front-end controller is presented for the sake of reducing the quantitative errors while getting the maximum ENOB (effective number of bits) of ADC (analog-to-digital converter) during waveform digitizing, as well as reducing the losing counts. Methods: First of all, the quantitative relationship among the radiation count rate (n), the amplitude of input signal (V in ), the conversion scale of ADC (±V) and the amplification factor (A) was derived. Secondly, the hardware and software of the front-end controller were designed to fulfill matching the output of different detectors, adjusting the amplification linearly through the control of channel switching, and setting of digital potentiometer by CPLD (Complex Programmable Logic Device). Results: (1) Through the measurement of γ-ray of Am-241 under our digital nuclear measurement set-up with CZT detector, it was validated that the amplitude of output signal of detectors of RC feedback type could be amplified linearly with adjustable amplification by the front-end controller. (2) Through the measurement of X-ray spectrum of Fe-5.5 under our digital nuclear measurement set-up with Si-PIN detector, it was validated that the front-end controller was suitable for the switch resetting type detectors, by which high precision measurement under various count rates could be fulfilled. Conclusion: The principle and method of the parameter-adjustable front-end controller presented in this paper is correct and feasible. (authors)

  9. Recommendations for certification or measurement of reliability for reliable digital archival repositories with emphasis on access

    Directory of Open Access Journals (Sweden)

    Paula Regina Ventura Amorim Gonçalez

    2017-04-01

    Full Text Available Introduction: Considering the guidelines of ISO 16363: 2012 (Space data and information transfer systems -- Audit and certification of trustworthy digital repositories and the text of CONARQ Resolution 39 for certification of Reliable Digital Archival Repository (RDC-Arq, verify the technical recommendations should be used as the basis for a digital archival repository to be considered reliable. Objective: Identify requirements for the creation of Reliable Digital Archival Repositories with emphasis on access to information from the ISO 16363: 2012 and CONARQ Resolution 39. Methodology: For the development of the study, the methodology consisted of an exploratory, descriptive and documentary theoretical investigation, since it is based on ISO 16363: 2012 and CONARQ Resolution 39. From the perspective of the problem approach, the study is qualitative and quantitative, since the data were collected, tabulated, and analyzed from the interpretation of their contents. Results: We presented a set of Checklist Recommendations for reliability measurement and/or certification for RDC-Arq with a clipping focused on the identification of requirements with emphasis on access to information is presented. Conclusions: The right to information as well as access to reliable information is a premise for Digital Archival Repositories, so the set of recommendations is directed to archivists who work in Digital Repositories and wish to verify the requirements necessary to evaluate the reliability of the Digital Repository or still guide the information professional in collecting requirements for repository reliability certification.

  10. Dynamic pipe control with a multiple digit automatic measuring device

    International Nuclear Information System (INIS)

    Jenzer, P.

    1984-01-01

    With the flow rotating method, thin-walled pipes can be produced with very tight tolerances and high mechanical sturdiness. The measuring device permits a dynamic control of these pipes, the outer diameter of which can lie between 70 and 300 mm, the length between 500 and 2000 mm and the wall thickness between 0,5 and 10 mm. Depending on the pipe type, up to 27 measurements in a maximum of 5 measuring levels are to be controlled. (orig.) [de

  11. Optical Measurement Techniques for Rocket Engine Testing and Component Applications: Digital Image Correlation and Dynamic Photogrammetry

    Science.gov (United States)

    Gradl, Paul

    2016-01-01

    NASA Marshall Space Flight Center (MSFC) has been advancing dynamic optical measurement systems, primarily Digital Image Correlation, for extreme environment rocket engine test applications. The Digital Image Correlation (DIC) technology is used to track local and full field deformations, displacement vectors and local and global strain measurements. This technology has been evaluated at MSFC through lab testing to full scale hotfire engine testing of the J-2X Upper Stage engine at Stennis Space Center. It has been shown to provide reliable measurement data and has replaced many traditional measurement techniques for NASA applications. NASA and AMRDEC have recently signed agreements for NASA to train and transition the technology to applications for missile and helicopter testing. This presentation will provide an overview and progression of the technology, various testing applications at NASA MSFC, overview of Army-NASA test collaborations and application lessons learned about Digital Image Correlation.

  12. Measurement of three-dimensional deformations using digital holography with radial sensitivity

    Energy Technology Data Exchange (ETDEWEB)

    Kohler, Christian; Viotti, Matias R.; Albertazzi, Jr.; G. Armando

    2010-07-10

    A measurement system based on digital holography for the simultaneous measurement of out-of-plane and radial in-plane displacement fields for the assessment of residual stress is presented. Two holograms are recorded at the same time with a single image taken by a digital camera, allowing the separate evaluation of in-plane and out-of-plane movement. An axis-symmetrical diffractive optical element is used for the illumination of the object, which causes radial sensitivity vectors. By the addition and, respectively, the subtraction, of the four phase maps calculated from two camera frames, the in-plane and out-of-plane deformation of an object can be calculated separately. The device presented is suitable for high-speed, high-resolution measurement of residual stress. In addition to the setup, first measurement results and a short comparison to a mature digital speckle pattern interferometry setup are shown.

  13. Digital holographic setups for phase object measurements in micro and macro scale

    Directory of Open Access Journals (Sweden)

    Lédl Vít

    2015-01-01

    Full Text Available The measurement of properties of so called phase objects is being solved for more than one Century starting probably with schlieren technique 1. Classical interferometry served as a great measurement tool for several decades and was replaced by holographic interferometry, which disposes with many benefits when compared to classical interferometry. Holographic interferometry undergone an enormous development in last decade when digital holography has been established as a standard technique and most of the drawbacks were solved. The paper deals with scope of the huge applicability of digital holographic interferometry in heat and mass transfer measurement from micro to macro scale and from simple 2D measurement up to complex tomographic techniques. Recently the very complex experimental setups are under development in our labs combining many techniques leading to digital holographic micro tomography methods.

  14. A compact wideband precision impedance measurement system based on digital auto-balancing bridge

    International Nuclear Information System (INIS)

    Hu, Binxin; Wang, Jinyu; Song, Guangdong; Zhang, Faxiang

    2016-01-01

    The ac impedance spectroscopy measurements are predominantly taken by using impedance analyzers based on analog auto-balancing bridge. However, those bench-top analyzers are generally complicated, bulky and expensive, thus limiting their usage in industrial field applications. This paper presents the development of a compact wideband precision measurement system based on digital auto-balancing bridge. The methods of digital auto-balancing bridge and digital lock-in amplifier are analyzed theoretically. The overall design and several key sections including null detector, direct digital synthesizer-based sampling clock, and digital control unit are introduced in detail. The results show that the system achieves a basic measurement accuracy of 0.05% with a frequency range of 20 Hz–2 MHz. The advantages of versatile measurement capacity, fast measurement speed, small size and low cost make it quite suitable for industrial field applications. It is demonstrated that this system is practical and effective by applying in determining the impedance-temperature characteristic of a motor starter PTC thermistor. (paper)

  15. Wall thickness measurements using digital radiography - state of the art

    International Nuclear Information System (INIS)

    Wawrzinek, T.; Zscherpel, U.; Bellon, C.

    1997-01-01

    Projection radiography is a method long since used for wall thickness measurements in pipes. Another method sometimes applied is thickness determination based on measuring changes of the optical density by using radioactive isotopes, as in this case the effects of stray radiation are negligible. The two methods hitherto were to be performed manually, and wall thickness data were derived by calculations with a pocket calculator. The required measuring and calculating work can now be automated by way of computerized processing of digitised images. The paper presents the software for automated evaluation of data of a selected location after system calibration. (orig./CB) [de

  16. Analysis of the Measurement and Modeling of a Digital Inverter Based on a Ferroelectric Transistor

    Science.gov (United States)

    MacLeod, Todd C.; Phillips, Thomas A.; Sayyah, Rana; Ho, Fat D.

    2009-01-01

    The use of ferroelectric materials for digital memory devices is widely researched and implemented, but ferroelectric devices also possess unique characteristics that make them have interesting and useful properties in digital circuits. Because ferroelectric transistors possess the properties of hysteresis and nonlinearity, a digital inverter containing a FeFET has very different characteristics than one with a traditional FET. This paper characterizes the properties of the measurement and modeling of a FeFET based digital inverter. The circuit was set up using discrete FeFETs. The purpose of this circuit was not to produce a practical integrated circuit that could be inserted directly into existing digital circuits, but to explore the properties and characteristics of such a device and to look at possible future uses. Input and output characteristics are presented, as well as timing measurements. Comparisons are made between the ferroelectric device and the properties of a standard digital inverter. Potential benefits and possible uses of such a device are presented.

  17. Experimental testing of the digital multichannel analyzer for gamma spectrometry measurements

    International Nuclear Information System (INIS)

    Novkovic, D.; Nadjdjerdj, L.; Kandic, A.; Vukanac, I.; Djurasevic, M.

    2008-01-01

    The results of experimental testing of the digital multichannel analyzer which digitalizes the signal after a preamplifier are presented. The recordings of some of the characteristics of the spectrometer containing a digital MCA, such as full-peak efficiency, net-area ratio of the two peaks and the stability of the peak position, were carried out under different input counting rates, with different radioactive sources. The tested MCA has shown some excellent features, like the stability of the peak position over a long-term period and flexibility in the adjusting of optimum measurement conditions. However, the performed tests have also shown some serious and unexpected disadvantages of the digital MCA when it operates under certain circumstances, one of them having to do with the automatic tuning of live-time correction at low-input counting rates. (author)

  18. Practical Measurement and Productive Persistence: Strategies for Using Digital Learning System Data to Drive Improvement

    Science.gov (United States)

    Krumm, Andrew E.; Beattie, Rachel; Takahashi, Sola; D'Angelo, Cynthia; Feng, Mingyu; Cheng, Britte

    2016-01-01

    This paper outlines the development of practical measures of productive persistence using digital learning system data. Practical measurement refers to data collection and analysis approaches originating from improvement science; productive persistence refers to the combination of academic and social mindsets as well as learning behaviours that…

  19. Difference between manual and digital measurements of dental arches of orthodontic patients.

    Science.gov (United States)

    Jiménez-Gayosso, Sandra Isabel; Lara-Carrillo, Edith; López-González, Saraí; Medina-Solís, Carlo Eduardo; Scougall-Vilchis, Rogelio José; Hernández-Martínez, César Tadeo; Colomé-Ruiz, Gabriel Eduardo; Escoffié-Ramirez, Mauricio

    2018-06-01

    The objective of this study was to compare the differences between the measurements performed manually to those obtained using a digital model scanner of patients with orthodontic treatment.A cross-sectional study was performed in a sample of 30 study models from patients with permanent dentition who attended a university clinic between January 2010 and December 2015. For the digital measurement, a Maestro 3D Ortho Studio scanner (Italy) was used and Mitutoyo electronic Vernier calipers (Kawasaki, Japan) were used for manual measurement. The outcome variables were the measurements for maxillary intercanine width, mandibular intercanine width, maxillary intermolar width, mandibular intermolar width, overjet, overbite, maxillary arch perimeter, mandibular arch perimeter, and palate height. The independent variables, besides age and sex, were a series of arc characteristics. The Student t test, paired Student t test, and Pearson correlation in SPSS version 19 were used for the analysis.Of the models, 60% were from women. Two of nine measurements for pre-treatment and 6 of 9 measurements for post-treatment showed a difference. The variables that were different between the manual and digital measurements in the pre-treatment were maxillary intermolar width and palate height (P manually and digitally showed certain similarities for both vertical and transverse measurements. There are many advantages offered to the orthodontist, such as easy storage; savings in time and space; facilitating the reproducibility of information; and conferring the security of not deteriorating over time. Its main disadvantage is the cost.

  20. Digital Thickness Measurement of a Transparent Plastic Orthodontic Device

    Science.gov (United States)

    Kim, Yoon-Hwan; Rhim, Sung-Han

    2018-05-01

    A transparent orthodontic device is used to move the teeth to the final calibration position to form a proper set of teeth. Because the uniform thickness of the device plays an important role in tooth positioning, the accuracy of the device's thickness profile is important for effective orthodontic treatment. However, due to the complexity of the device's geometry and the transparency of the device's material, measuring the complete thickness profile has been difficult. In the present study, a new optical scanning method to measure the thickness profile of transparent plastic orthodontic devices is proposed and evaluated by using scanning electron microscopy (SEM). The error of the new measurement method is less than ±18 μm. The new method can be used to measure the thickness of non-specific, multi-curved, transparent orthodontic devices.

  1. Accuracy of 3-dimensional curvilinear measurements on digital models with intraoral scanners.

    Science.gov (United States)

    Mack, Spencer; Bonilla, Tammy; English, Jeryl D; Cozad, Benjamin; Akyalcin, Sercan

    2017-09-01

    Our objectives were to evaluate and compare the digital dental models generated from 2 commercial intraoral scanners with manual measurements when performing 3-dimensional surface measurements along a curved line (curvilinear). Dry mandibles (n = 61) with intact dentition were used. The mandibles were digitized using 2 chair-side intraoral scanners: Cadent iTero (Align Technology, San Jose, Calif) and Lythos Digital Impression system (Ormco, Orange, Calif). Digitized 3-dimensional models were converted to individual stereolithography files and used with commercial software to obtain the curvilinear measurements. Manual measurements were carried out directly on the mandibular teeth. Measurements were made on different locations on the dental arch in various directions. One-sample t tests and linear regression analyses were performed. To further graphically examine the accuracy between the different methods, Bland-Altman plots were computed. The level of significance was set at P 0.05). Bland-Altman analysis showed no fixed bias of 1 approach vs the other, and random errors were detected in all comparisons. Although the mean biases of the digital models obtained by the iTero and Lythos scanners, when compared with direct caliper measurements, were low, the comparison of the 2 intraoral scanners yielded the lowest mean bias. No comparison displayed statistical significance for the t scores; this indicated the absence of proportional bias in these comparisons. The intraoral scanners tested in this study produced digital dental models that were comparatively accurate when performing direct surface measurements along a curved line in 3 dimensions. Copyright © 2017 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  2. Correlation between maximum voluntary contraction and endurance measured by digital palpation and manometry: An observational study

    Directory of Open Access Journals (Sweden)

    Fátima Faní Fitz

    Full Text Available Summary Introduction: Digital palpation and manometry are methods that can provide information regarding maximum voluntary contraction (MVC and endurance of the pelvic floor muscles (PFM, and a strong correlation between these variables can be expected. Objective: To investigate the correlation between MVC and endurance, measured by digital palpation and manometry. Method: Forty-two women, with mean age of 58.1 years (±10.2, and predominant symptoms of stress urinary incontinence (SUI, were included. Examination was firstly conducted by digital palpation and subsequently using a Peritron manometer. MVC was measured using a 0-5 score, based on the Oxford Grading Scale. Endurance was assessed based on the PERFECT scheme. Results: We found a significant positive correlation between the MVC measured by digital palpation and the peak manometric pressure (r=0.579, p<0.001, and between the measurements of the endurance by Peritron manometer and the PERFECT assessment scheme (r=0.559, P<0.001. Conclusion: Our results revealed a positive and significant correlation between the capacity and maintenance of PFM contraction using digital and manometer evaluations in women with predominant symptoms of SUI.

  3. Development of digital photogrammetry for measurements of displacements in underground excavation

    International Nuclear Information System (INIS)

    Ohnishi, Yuzo; Ohtsu, Hiroyasu; Nishiyama, Satoshi; Ono, Tetsu; Matsui, Hiroya

    2002-03-01

    Because deformations are important indicators of the degree of stability during construction of rock structures, monitoring of deformation is a key element of construction of tunnels and structures for the underground research laboratory. Especially in the construction and maintenance of underground excavation, monitoring of deformations is needed for obtaining useful information to control its stability. We have been developing the application of digital photogrammetry to monitoring techniques in rock structures. Photogrammetric process has undergone a remarkable evolution with its transformation into digital photogrammetry. Photogrammetry has the advantage of measuring deformation of an object by some photos with easy measurements and excellent cost performance. In this paper, we present that the digital photogrammetry can monitor the displacements of the underground excavation accurately along with a capability of real-time measurement. (author)

  4. Refining Measures for Assessing Problematic/Addictive Digital Gaming Use in Clinical and Research Settings

    Directory of Open Access Journals (Sweden)

    Kyle Faust

    2015-08-01

    Full Text Available Problematic or addictive digital gaming (including all types of electronic devices can and has had extremely adverse impacts on the lives of many individuals across the world. The understanding of this phenomenon, and the effectiveness of treatment design and monitoring, can be improved considerably by continuing refinement of assessment tools. The present article briefly overviews tools designed to measure problematic or addictive use of digital gaming, the vast majority of which are founded on the Diagnostic and Statistical Manual of Mental Disorders (DSM criteria for other addictive disorders, such as pathological gambling. Although adapting DSM content and strategies for measuring problematic digital gaming has proven valuable, there are some potential issues with this approach. We discuss the strengths and limitations of current methods for measuring problematic or addictive gaming and provide various recommendations that might help in enhancing or supplementing existing tools, or in developing new and even more effective tools.

  5. Refining Measures for Assessing Problematic/Addictive Digital Gaming Use in Clinical and Research Settings.

    Science.gov (United States)

    Faust, Kyle; Faust, David

    2015-08-12

    Problematic or addictive digital gaming (including all types of electronic devices) can and has had extremely adverse impacts on the lives of many individuals across the world. The understanding of this phenomenon, and the effectiveness of treatment design and monitoring, can be improved considerably by continuing refinement of assessment tools. The present article briefly overviews tools designed to measure problematic or addictive use of digital gaming, the vast majority of which are founded on the Diagnostic and Statistical Manual of Mental Disorders (DSM) criteria for other addictive disorders, such as pathological gambling. Although adapting DSM content and strategies for measuring problematic digital gaming has proven valuable, there are some potential issues with this approach. We discuss the strengths and limitations of current methods for measuring problematic or addictive gaming and provide various recommendations that might help in enhancing or supplementing existing tools, or in developing new and even more effective tools.

  6. Fine Metal Mask 3-Dimensional Measurement by using Scanning Digital Holographic Microscope

    Science.gov (United States)

    Shin, Sanghoon; Yu, Younghun

    2018-04-01

    For three-dimensional microscopy, fast and high axial resolution are very important. Extending the depth of field for digital holographic is necessary for three-dimensional measurements of thick samples. We propose an optical sectioning method for optical scanning digital holography that is performed in the frequency domain by spatial filtering of a reconstructed amplitude image. We established a scanning dual-wavelength off-axis digital holographic microscope to measure samples that exhibit a large amount of coherent noise and a thickness larger than the depth of focus of the objective lens. As a demonstration, we performed a three-dimensional measurement of a fine metal mask with a reconstructed sectional phase image and filtering with a reconstructed amplitude image.

  7. Measurement of width and step-height of photolithographic product patterns by using digital holography

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Ju Yeop; Kang, Sung Hoon; Ma, Hye Joon; Jung, Hyun Chul; Hong, Chung Ki; Kim, Kyeong Suk [Chosun University, Gwangju (Korea, Republic of); Kwon, Ik Hwan [Dept. of Physics, Pohang University of Science and Technology, Pohang (Korea, Republic of); Yang, Seung Pil [Dept. of Ophthalmic Optics, Dong A College of Health, Youngam (Korea, Republic of)

    2016-02-15

    The semiconductor industry is one of the key industries of Korea, which has continued growing at a steady annual growth rate. Important technology for the semiconductor industry is high integration of devices. This is to increase the memory capacity for unit area, of which key is photolithography. The photolithography refers to a technique for printing the shadow of light lit on the mask surface on to wafer, which is the most important process in a semiconductor manufacturing process. In this study, the width and step-height of wafers patterned through this process were measured to ensure uniformity. The widths and inter-plate heights of the specimens patterned using photolithography were measured using transmissive digital holography. A transmissive digital holographic interferometer was configured, and nine arbitrary points were set on the specimens as measured points. The measurement of each point was compared with the measurements performed using a commercial device called scanning electron microscope (SEM) and Alpha Step. Transmission digital holography requires a short measurement time, which is an advantage compared to other techniques. Furthermore, it uses magnification lenses, allowing the flexibility of changing between high and low magnifications. The test results confirmed that transmissive digital holography is a useful technique for measuring patterns printed using photolithography.

  8. Comarability of digital and analouge x-rays for migration measurements with EBRA

    International Nuclear Information System (INIS)

    Brabec, E.

    2001-02-01

    EBRA is a computer supported method for measuring the migration of total hip prostheses by using consecutive standard X-rays of the pelvis. PACS is a picture archiving and communication system used to handle digitally taken X-rays. After the installation of a PACS at the University Clinic of Innsbruck it was impossible to compare the digital pictures with the former analogue pictures with EBRA, as they have different scales. By introducing a calibrating step into the EBRA-program it was possible to do measurements on series of pictures containing digital pictures as well as analogue ones. For displaying the failure of EBRA caused by different radiological techniques we did measurements on a series of consecutive X-rays taken of a model made of acrylic glass and simulating the relevant anatomic structures by screws. The migration of the implant was simulated by shifting it in two directions. Whilst using analogue and digital radiological techniques for taking X-rays, the difference in measurement errors of both techniques was studied. The reliable comparability of X-rays of every format is an absolute necessity for continuing measurements of migration after changing the technique of taking X-rays. The average measurement error of all studied formats of pictures was 0.04 mm (Stdev. 0.11 mm). Though, by using the calibration tool of EBRA migration measurement on X-rays with different formats is possible within the same accuracy. (author)

  9. Measurement of width and step-height of photolithographic product patterns by using digital holography

    International Nuclear Information System (INIS)

    Shin, Ju Yeop; Kang, Sung Hoon; Ma, Hye Joon; Jung, Hyun Chul; Hong, Chung Ki; Kim, Kyeong Suk; Kwon, Ik Hwan; Yang, Seung Pil

    2016-01-01

    The semiconductor industry is one of the key industries of Korea, which has continued growing at a steady annual growth rate. Important technology for the semiconductor industry is high integration of devices. This is to increase the memory capacity for unit area, of which key is photolithography. The photolithography refers to a technique for printing the shadow of light lit on the mask surface on to wafer, which is the most important process in a semiconductor manufacturing process. In this study, the width and step-height of wafers patterned through this process were measured to ensure uniformity. The widths and inter-plate heights of the specimens patterned using photolithography were measured using transmissive digital holography. A transmissive digital holographic interferometer was configured, and nine arbitrary points were set on the specimens as measured points. The measurement of each point was compared with the measurements performed using a commercial device called scanning electron microscope (SEM) and Alpha Step. Transmission digital holography requires a short measurement time, which is an advantage compared to other techniques. Furthermore, it uses magnification lenses, allowing the flexibility of changing between high and low magnifications. The test results confirmed that transmissive digital holography is a useful technique for measuring patterns printed using photolithography

  10. Measurements with a High-Granularity Digital Electromagnetic Calorimeter

    NARCIS (Netherlands)

    Zhang, C.

    2017-01-01

    The low-x structure of protons and in particular nuclei is not well constrained experimentally, while the knowledge about it is a crucial ingredient for the interpretation of many measurements at high-energy hadron colliders. It is widely expected that the growth of parton densities at low x

  11. Automated digital volume measurement of melanoma metastases in sentinel nodes predicts disease recurrence and survival

    DEFF Research Database (Denmark)

    Riber-Hansen, Rikke; Nyengaard, Jens R; Hamilton-Dutoit, Stephen J

    2011-01-01

    statistics (categorical data). In addition, disease-free and melanoma-specific survivals were calculated. Mean metastatic volume per patient was 10.6 mm(3) (median 0.05 mm(3); range 0.0001-621.3 mm(3)) and 9.62 mm(3) (median 0.05 mm(3); range 0.00001-564.3 mm(3)) with manual and digital measurement......, respectively. The Bland-Altman plot showed an even distribution of the differences, and the kappa statistic was 0.84. In multivariate analysis, both manual and digital metastasis volume measurements were independent progression markers when corrected for primary tumour thickness [manual: hazard ratio (HR): 1...

  12. Measurement of Three-Dimensional Deformations by Phase-Shifting Digital Holographic Interferometry

    Directory of Open Access Journals (Sweden)

    Percival Almoro

    2003-06-01

    Full Text Available Out-of-plane deformations of a cantilever were measured using phase-shifting digital holographicinterferometry (PSDHI and the Fourier transform method (FTM. The cantilever was recorded in twodifferent states, and holograms were stored electronically with a charge-coupled device (CCD camera.When the holograms are superimposed and reconstructed jointly, a holographic interferogram results.The three-dimensional (3D surface deformations were successfully visualized by applying FTM toholographic interferogram analysis. The minimum surface displacement measured was 0.317 µm. Theprocessing time for the digital reconstruction and visualization of 3D deformation took about 1 minute.The technique was calibrated using Michelson interferometry setup.

  13. [Comparison of body temperatures in children measured using 3 different thermometers: tympanic, skin and digital axillary].

    Science.gov (United States)

    Padilla-Raygoza, Nicolás; Ruiz-Paloalto, M Laura; Díaz-Guerrero, Rosalina; Olvera-Villanueva, Georgina; Maldonado, Angélica; Raygoza-Mendoza, María Del Pilar

    2014-01-01

    To compare body temperature measurements using tympanic, skin and digital axillary thermometers. Hospitalized or outpatient children from the General Hospital Celaya, ISSSTE Hospital Clinic and General Hospital No. 4 IMSS, and the pediatric private service in Celaya, Guanajuato, from 1 day of life until 16 years old, were recruited over a one month period, after their parents signed the consent form. The order of each institution was selected by simple randomization. Body temperatures were measured in triplicate using tympanic, skin and digital axillary thermometers. The sample consisted of 554 children. The Pearson r between the tympanic and digital axillary thermometers was 0.57 to 0.65, with a positive linear relationship (P<.05); between the skin and the digital axillary thermometers, it was between 0.47 and 0.52 with a positive linearrelationship (P<.05). The intra-observer Kappa for the tympanic thermometer was 0.86, and for the inter-observer was 0.77; for the skin thermometer it was 0.82 and 0.67, respectively, and for the digital axillary thermometer it was 0.86 for intra-observer reliability and 0.78 for inter -observer reliability. Tympanic and axillary thermometers showed better precision in measuring the body temperature in children than skin thermometers. Copyright © 2013 Elsevier España, S.L. All rights reserved.

  14. Surface topography measurement by frequency sweeping digital holography.

    Czech Academy of Sciences Publication Activity Database

    Lédl, Vít; Psota, Pavel; Kaván, František; Matoušek, Ondřej; Mokrý, Pavel

    2017-01-01

    Roč. 56, č. 28 (2017), s. 7808-7814 ISSN 1559-128X R&D Projects: GA MŠk(CZ) LO1206; GA ČR(CZ) GA16-11965S Institutional support: RVO:61389021 Keywords : Wavelenght Scanning Interferometry * Shape measurement * Profilomerty Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering OBOR OECD: Electrical and electronic engineering Impact factor: 1.650, year: 2016 https://doi.org/10.1364/AO.56.007808

  15. Evaluating digital libraries in the health sector. Part 1: measuring inputs and outputs.

    Science.gov (United States)

    Cullen, Rowena

    2003-12-01

    This is the first part of a two-part paper which explores methods that can be used to evaluate digital libraries in the health sector. In this first part, some approaches to evaluation that have been proposed for mainstream digital information services are examined for their suitability to provide models for the health sector. The paper summarizes some major national and collaborative initiatives to develop measures for digital libraries, and analyses these approaches in terms of their relationship to traditional measures of library performance, which are focused on inputs and outputs, and their relevance to current debates among health information specialists. The second part* looks more specifically at evaluative models based on outcomes, and models being developed in the health sector.

  16. Improving the phase measurement by the apodization filter in the digital holography

    Science.gov (United States)

    Chang, Shifeng; Wang, Dayong; Wang, Yunxin; Zhao, Jie; Rong, Lu

    2012-11-01

    Due to the finite size of the hologram aperture in digital holography, high frequency intensity and phase fluctuations along the edges of the images, which reduce the precision of phase measurement. In this paper, the apodization filters are applied to improve the phase measurement in the digital holography. Firstly, the experimental setup of the lensless Fourier transform digital holography is built, where the sample is a standard phase grating with the grating constant of 300μm and the depth of 150nm. Then, apodization filters are applied to phase measurement of the sample with three kinds of the window functions: Tukey window, Hanning window and Blackman window, respectively. Finally, the results were compared to the detection data given by the commercial white-light interferometer. It is shown that aperture diffraction effects can be reduced by the digital apodization, and the phase measurement with the apodization is more accurate than in the unapodized case. Meanwhile, the Blackman window function produces better effect than the other two window functions in the measurement of the standard phase grating.

  17. Questioning short-term memory and its measurement: Why digit span measures long-term associative learning.

    Science.gov (United States)

    Jones, Gary; Macken, Bill

    2015-11-01

    Traditional accounts of verbal short-term memory explain differences in performance for different types of verbal material by reference to inherent characteristics of the verbal items making up memory sequences. The role of previous experience with sequences of different types is ostensibly controlled for either by deliberate exclusion or by presenting multiple trials constructed from different random permutations. We cast doubt on this general approach in a detailed analysis of the basis for the robust finding that short-term memory for digit sequences is superior to that for other sequences of verbal material. Specifically, we show across four experiments that this advantage is not due to inherent characteristics of digits as verbal items, nor are individual digits within sequences better remembered than other types of individual verbal items. Rather, the advantage for digit sequences stems from the increased frequency, compared to other verbal material, with which digits appear in random sequences in natural language, and furthermore, relatively frequent digit sequences support better short-term serial recall than less frequent ones. We also provide corpus-based computational support for the argument that performance in a short-term memory setting is a function of basic associative learning processes operating on the linguistic experience of the rememberer. The experimental and computational results raise questions not only about the role played by measurement of digit span in cognition generally, but also about the way in which long-term memory processes impact on short-term memory functioning. Copyright © 2015 The Authors. Published by Elsevier B.V. All rights reserved.

  18. Development of digital power measuring and protecting equipment for SPRR-300 reactor

    International Nuclear Information System (INIS)

    Wang Xuejie; Li Xi'an; Zhu Shilei

    2005-01-01

    A measuring and protecting equipment of reactor power based on Single-Chip Microcomputer is introduced in this paper. The composition of hardware and the major control idea about the software for the equipment are presented. Digitizing the measuring data from nuclear instruments is precondition of reactor control and protection system which would be computerizing, and it is also an application of redundancy and variety of reactor protection system in nuclear measuring instruments. At last the working state is described. (authors)

  19. Smart phone-based Chemistry Instrumentation: Digitization of Colorimetric Measurements

    International Nuclear Information System (INIS)

    Chang, Byoung Yong

    2012-01-01

    This report presents a mobile instrumentation platform based on a smart phone using its built-in functions for colorimetric diagnosis. The color change as a result of detection is taken as a picture through a CCD camera built in the smart phone, and is evaluated in the form of the hue value to give the well-defined relationship between the color and the concentration. To prove the concept in the present work, proton concentration measurements were conducted on pH paper coupled with a smart phone for demonstration. This report is believed to show the possibility of adapting a smart phone to a mobile analytical transducer, and more applications for bioanalysis are expected to be developed using other built-in functions of the smart phone

  20. Bilateral bone conduction devices: improved hearing ability in children with bilateral conductive hearing loss.

    Science.gov (United States)

    Dun, Catharina A J; Agterberg, Martijn J H; Cremers, Cor W R J; Hol, Myrthe K S; Snik, Ad F M

    2013-01-01

    The aim of the study was to investigate whether children with bilateral conductive hearing loss benefit from their second device (i.e., the bilateral bone conduction device [BCD]). Speech recognition in noise was assessed in 10 children fitted with bilateral BCDs during childhood. Speech recognition was measured in 2 conditions with both BCDs active. Spatial resolution was tested with the Minimum Audible Angle test in the bilateral and monaural listening conditions. Children demonstrated an improvement in speech recognition when speech was presented from the front and noise was presented from the right-hand side as compared with both speech and noise being presented from the front. The minimum audible angle decreased from 57° in the best monaural condition to 13° in the bilateral condition. The audiological outcomes demonstrate the advantage of bilateral BCD fitting in children with bilateral conductive hearing loss.

  1. A comparison of hair colour measurement by digital image analysis with reflective spectrophotometry.

    Science.gov (United States)

    Vaughn, Michelle R; van Oorschot, Roland A H; Baindur-Hudson, Swati

    2009-01-10

    While reflective spectrophotometry is an established method for measuring macroscopic hair colour, it can be cumbersome to use on a large number of individuals and not all reflective spectrophotometry instruments are easily portable. This study investigates the use of digital photographs to measure hair colour and compares its use to reflective spectrophotometry. An understanding of the accuracy of colour determination by these methods is of relevance when undertaking specific investigations, such as those on the genetics of hair colour. Measurements of hair colour may also be of assistance in cases where a photograph is the only evidence of hair colour available (e.g. surveillance). Using the CIE L(*)a(*)b(*) colour space, the hair colour of 134 individuals of European ancestry was measured by both reflective spectrophotometry and by digital image analysis (in V++). A moderate correlation was found along all three colour axes, with Pearson correlation coefficients of 0.625, 0.593 and 0.513 for L(*), a(*) and b(*) respectively (p-values=0.000), with means being significantly overestimated by digital image analysis for all three colour components (by an average of 33.42, 3.38 and 8.00 for L(*), a(*) and b(*) respectively). When using digital image data to group individuals into clusters previously determined by reflective spectrophotometric analysis using a discriminant analysis, individuals were classified into the correct clusters 85.8% of the time when there were two clusters. The percentage of cases correctly classified decreases as the number of clusters increases. It is concluded that, although more convenient, hair colour measurement from digital images has limited use in situations requiring accurate and consistent measurements.

  2. The influence of the group delay of digital filters on acoustic decay measurements

    DEFF Research Database (Denmark)

    Sobreira-Seoane, Manuel A.; Cabo, David Pérez; Jacobsen, Finn

    2012-01-01

    In this paper the error due to the phase response of digital filters on acoustic decay measurements is analyzed. There are two main sources of errors when an acoustic decay is filtered: the error due to the bandwidth of the filters related to their magnitude response, and the error due to their p...

  3. Radiological findings for hip dysplasia at skeletal maturity. Validation of digital and manual measurement techniques

    Energy Technology Data Exchange (ETDEWEB)

    Engesaeter, Ingvild Oevsteboe [University of Bergen, Department of Surgical Sciences, Bergen (Norway); Haukeland University Hospital, Department of Orthopaedic Surgery, Bergen (Norway); Haukeland University Hospital, Department of Radiology, Bergen (Norway); Haukeland University Hospital, The Norwegian Arthroplasty Register, Department of Orthopaedic Surgery, Bergen (Norway); Laborie, Lene Bjerke; Rosendahl, Karen [University of Bergen, Department of Surgical Sciences, Bergen (Norway); Haukeland University Hospital, Department of Radiology, Bergen (Norway); Lehmann, Trude Gundersen; Fevang, Jonas; Engesaeter, Lars Birger [University of Bergen, Department of Surgical Sciences, Bergen (Norway); Haukeland University Hospital, Department of Orthopaedic Surgery, Bergen (Norway); Sera, Francesco [University College London Institute of Child Health, Medical Research Council Centre of Epidemiology for Child Health, London (United Kingdom); Pedersen, Douglas; Morcuende, Jose [University of Iowa Hospital and Clinics, Department of Orthopaedics and Rehabilitation, Iowa City, IA (United States); Lie, Stein Atle [Uni Health, Uni Research, Bergen (Norway)

    2012-07-15

    To report on intra-observer, inter-observer, and inter-method reliability and agreement for radiological measurements used in the diagnosis of hip dysplasia at skeletal maturity, as obtained by a manual and a digital measurement technique. Pelvic radiographs from 95 participants (56 females) in a follow-up hip study of 18- to 19-year-old patients were included. Eleven radiological measurements relevant for hip dysplasia (Sharp's, Wiberg's, and Ogata's angles; acetabular roof angle of Toennis; articulo-trochanteric distance; acetabular depth-width ratio; femoral head extrusion index; maximum teardrop width; and the joint space width in three different locations) were validated. Three observers measured the radiographs using both a digital measurement program and manually in AgfaWeb1000. Inter-method and inter- and intra-observer agreement were analyzed using the mean differences between the readings/readers, establishing the 95% limits of agreement. We also calculated the minimum detectable change and the intra-class correlation coefficient. Large variations among different radiological measurements were demonstrated. However, the variation was not related to the use of either the manual or digital measurement technique. For measurements with greater absolute values (Sharp's angle, femoral head extrusion index, and acetabular depth-width ratio) the inter- and intra-observer and inter-method agreements were better as compared to measurements with lower absolute values (acetabular roof angle, teardrop and joint space width). The inter- and intra-observer variation differs notably across different radiological measurements relevant for hip dysplasia at skeletal maturity, a fact that should be taken into account in clinical practice. The agreement between the manual and digital methods is good. (orig.)

  4. Radiological findings for hip dysplasia at skeletal maturity. Validation of digital and manual measurement techniques.

    Science.gov (United States)

    Engesæter, Ingvild Øvstebø; Laborie, Lene Bjerke; Lehmann, Trude Gundersen; Sera, Francesco; Fevang, Jonas; Pedersen, Douglas; Morcuende, José; Lie, Stein Atle; Engesæter, Lars Birger; Rosendahl, Karen

    2012-07-01

    To report on intra-observer, inter-observer, and inter-method reliability and agreement for radiological measurements used in the diagnosis of hip dysplasia at skeletal maturity, as obtained by a manual and a digital measurement technique. Pelvic radiographs from 95 participants (56 females) in a follow-up hip study of 18- to 19-year-old patients were included. Eleven radiological measurements relevant for hip dysplasia (Sharp's, Wiberg's, and Ogata's angles; acetabular roof angle of Tönnis; articulo-trochanteric distance; acetabular depth-width ratio; femoral head extrusion index; maximum teardrop width; and the joint space width in three different locations) were validated. Three observers measured the radiographs using both a digital measurement program and manually in AgfaWeb1000. Inter-method and inter- and intra-observer agreement were analyzed using the mean differences between the readings/readers, establishing the 95% limits of agreement. We also calculated the minimum detectable change and the intra-class correlation coefficient. Large variations among different radiological measurements were demonstrated. However, the variation was not related to the use of either the manual or digital measurement technique. For measurements with greater absolute values (Sharp's angle, femoral head extrusion index, and acetabular depth-width ratio) the inter- and intra-observer and inter-method agreements were better as compared to measurements with lower absolute values (acetabular roof angle, teardrop and joint space width). The inter- and intra-observer variation differs notably across different radiological measurements relevant for hip dysplasia at skeletal maturity, a fact that should be taken into account in clinical practice. The agreement between the manual and digital methods is good.

  5. Measurement of curvature and twist of a deformed object using digital holography

    International Nuclear Information System (INIS)

    Chen Wen; Quan Chenggen; Cho Jui Tay

    2008-01-01

    Measurement of curvature and twist is an important aspect in the study of object deformation. In recent years, several methods have been proposed to determine curvature and twist of a deformed object using digital shearography. Here we propose a novel method to determine the curvature and twist of a deformed object using digital holography and a complex phasor. A sine/cosine transformation method and two-dimensional short time Fourier transform are proposed subsequently to process the wrapped phase maps. It is shown that high-quality phase maps corresponding to curvature and twist can be obtained. An experiment is conducted to demonstrate the validity of the proposed method

  6. A model for measurement of noise in CCD digital-video cameras

    International Nuclear Information System (INIS)

    Irie, K; Woodhead, I M; McKinnon, A E; Unsworth, K

    2008-01-01

    This study presents a comprehensive measurement of CCD digital-video camera noise. Knowledge of noise detail within images or video streams allows for the development of more sophisticated algorithms for separating true image content from the noise generated in an image sensor. The robustness and performance of an image-processing algorithm is fundamentally limited by sensor noise. The individual noise sources present in CCD sensors are well understood, but there has been little literature on the development of a complete noise model for CCD digital-video cameras, incorporating the effects of quantization and demosaicing

  7. Chirped pulse digital holography for measuring the sequence of ultrafast optical wavefronts

    Science.gov (United States)

    Karasawa, Naoki

    2018-04-01

    Optical setups for measuring the sequence of ultrafast optical wavefronts using a chirped pulse as a reference wave in digital holography are proposed and analyzed. In this method, multiple ultrafast object pulses are used to probe the temporal evolution of ultrafast phenomena and they are interfered with a chirped reference wave to record a digital hologram. Wavefronts at different times can be reconstructed separately from the recorded hologram when the reference pulse can be treated as a quasi-monochromatic wave during the pulse width of each object pulse. The feasibility of this method is demonstrated by numerical simulation.

  8. ImageJ: A Free, Easy, and Reliable Method to Measure Leg Ulcers Using Digital Pictures.

    Science.gov (United States)

    Aragón-Sánchez, Javier; Quintana-Marrero, Yurena; Aragón-Hernández, Cristina; Hernández-Herero, María José

    2017-12-01

    Wound measurement to document the healing course of chronic leg ulcers has an important role in the management of these patients. Digital cameras in smartphones are readily available and easy to use, and taking pictures of wounds is becoming a routine in specialized departments. Analyzing digital pictures with appropriate software provides clinicians a quick, clean, and easy-to-use tool for measuring wound area. A set of 25 digital pictures of plain foot and leg ulcers was the basis of this study. Photographs were taken placing a ruler next to the wound in parallel with the healthy skin with the iPhone 6S (Apple Inc, Cupertino, CA), which has a camera of 12 megapixels using the flash. The digital photographs were visualized with ImageJ 1.45s freeware (National Institutes of Health, Rockville, MD; http://imagej.net/ImageJ ). Wound area measurement was carried out by 4 raters: head of the department, wound care nurse, physician, and medical student. We assessed intra- and interrater reliability using the interclass correlation coefficient. To determine intraobserver reliability, 2 of the raters repeated the measurement of the set 1 week after the first reading. The interrater model displayed an interclass correlation coefficient of 0.99 with 95% confidence interval of 0.999 to 1.000, showing excellent reliability. The intrarater model of both examiners showed excellent reliability. In conclusion, analyzing digital images of leg ulcers with ImageJ estimates wound area with excellent reliability. This method provides a free, rapid, and accurate way to measure wounds and could routinely be used to document wound healing in daily clinical practice.

  9. A digital approach for real time high-rate high-resolution radiation measurements

    International Nuclear Information System (INIS)

    Gerardi, G.; Abbene, L.

    2014-01-01

    Modern spectrometers are currently developed by using digital pulse processing (DPP) systems, showing several advantages over traditional analog electronics. The aim of this work is to present digital strategies, in a time domain, for the development of real time high-rate high-resolution spectrometers. We propose a digital method, based on the single delay line (SDL) shaping technique, able to perform multi-parameter analysis with high performance even at high photon counting rates. A robust pulse shape and height analysis (PSHA), applied on single isolated time windows of the detector output waveforms, is presented. The potentialities of the proposed strategy are highlighted through both theoretical and experimental approaches. To strengthen our approach, the implementation of the method on a real-time system together with some experimental results are presented. X-ray spectra measurements with a semiconductor detector are performed both at low and high photon counting rates (up to 1.1 Mcps)

  10. Differences in Measuring Market Risk in Four Subsectors of the Digital Economy

    Directory of Open Access Journals (Sweden)

    Sonia Benito

    2015-03-01

    Full Text Available This paper defends the wisdom of not considering the Digital Economy to be one homogeneous sector. Our hypothesis is that it is best to consider it the result of adding four different subsectors. We test whether indeed the economic and financial performance of a portfolio of listed companies in each of the four subsectors presents relevant differences. We use the value at risk measure to estimate market risk of the four subsectors of the digital economy. The riskiest subsector is Mobile/Internet Contents & Services followed by SW&IT Services and Application Software. On the contrary, the Telecom sector is by far the safest one. These results support the hypothesis that the Digital Economy is not a homogeneous sector.

  11. A digital approach for real time high-rate high-resolution radiation measurements

    Energy Technology Data Exchange (ETDEWEB)

    Gerardi, G.; Abbene, L., E-mail: leonardo.abbene@unipa.it

    2014-12-21

    Modern spectrometers are currently developed by using digital pulse processing (DPP) systems, showing several advantages over traditional analog electronics. The aim of this work is to present digital strategies, in a time domain, for the development of real time high-rate high-resolution spectrometers. We propose a digital method, based on the single delay line (SDL) shaping technique, able to perform multi-parameter analysis with high performance even at high photon counting rates. A robust pulse shape and height analysis (PSHA), applied on single isolated time windows of the detector output waveforms, is presented. The potentialities of the proposed strategy are highlighted through both theoretical and experimental approaches. To strengthen our approach, the implementation of the method on a real-time system together with some experimental results are presented. X-ray spectra measurements with a semiconductor detector are performed both at low and high photon counting rates (up to 1.1 Mcps)

  12. Digital pulse processing techniques for high resolution amplitude measurement of radiation detector

    International Nuclear Information System (INIS)

    Singhai, P.; Roy, A.; Dhara, P.; Chatterjee, S.

    2012-01-01

    The digital pulse processing techniques for high resolution amplitude measurement of radiation detector pulse is an effective replacement of expensive and bulky analog processing as the digital domain offers higher channel density and at the same time it is cheaper. We have demonstrated a prototype digital setup with highspeed sampling ADC with sampling frequency of 80-125 MHz followed by series of IIR filters for pulse shaping in a trigger-less acquisition mode. The IIR filters, peak detection algorithm and the data write-out logic was written on VHDL and implemented on FPGA. We used CAMAC as the read out platform. In conjunction with the full hardware implementation we also used a mixed platform with VME digitizer card with raw-sample read out using C code. The rationale behind this mixed platform is to test out various filter algorithms quickly on C and also to benchmark the performance of the chip level ADCs against the standard commercial digitizer in terms of noise or resolution. The paper describes implementation of both the methods with performance obtained in both the methods. (author)

  13. Three-dimensional motion measurements of free-swimming microorganisms using digital holographic microscopy

    International Nuclear Information System (INIS)

    Lee, Sang Joon; Seo, Kyung Won; Choi, Yong Seok; Sohn, Myong Hwan

    2011-01-01

    A digital holographic microscope is employed to measure the 3D motion of free-swimming microorganisms. The focus function used to quantify image sharpness provides a better depth-directional accuracy with a smaller depth-of-focus compared with the intensity method in determining the depth-directional position of spherical particles of various diameters. The focus function is then applied to measure the 3D positions of free-swimming microorganisms, namely dinoflagellates C. polykrikoides and P. minimum. Both automatic segmentation and proper selection of a focus function for a selected segment are important processes in measuring the positional information of two free-swimming microorganisms of different shapes with various width-to-length ratios. The digital holographic microscopy technique improved in this work is useful for measuring 3D swimming trajectories, velocities and attitudes of hundreds of microorganisms simultaneously. It also exhibits exceptional depth-directional accuracy

  14. Testing digital recursive filtering method for radiation measurement channel using pin diode detector

    International Nuclear Information System (INIS)

    Talpalariu, C. M.; Talpalariu, J.; Popescu, O.; Mocanasu, M.; Lita, I.; Visan, D. A.

    2016-01-01

    In this work we have studied a software filtering method implemented in a pulse counting computerized measuring channel using PIN diode radiation detector. In case our interest was focalized for low rate decay radiation measurement accuracies improvement and response time optimization. During works for digital mathematical algorithm development, we used a hardware radiation measurement channel configuration based on PIN diode BPW34 detector, preamplifier, filter and programmable counter, computer connected. We report measurement results using two digital recursive methods in statically and dynamically field evolution. Software for graphical input/output real time diagram representation was designed and implemented, facilitating performances evaluation between the response of fixed configuration software recursive filter and dynamically adaptive configuration recursive filter. (authors)

  15. Measurement of the Young's modulus of thin or flexible specimen with digital-image correlation method

    Science.gov (United States)

    Xu, Lianyun; Hou, Zhende; Qin, Yuwen

    2002-05-01

    Because some composite material, thin film material, and biomaterial, are very thin and some of them are flexible, the classical methods for measuring their Young's moduli, by mounting extensometers on specimens, are not available. A bi-image method based on image correlation for measuring Young's moduli is developed in this paper. The measuring precision achieved is one order enhanced with general digital image correlation or called single image method. By this way, the Young's modulus of a SS301 stainless steel thin tape, with thickness 0.067mm, is measured, and the moduli of polyester fiber films, a kind of flexible sheet with thickness 0.25 mm, are also measured.

  16. Safety assessment of inter-channel / inter-system digital communications: A defensive measures approach

    International Nuclear Information System (INIS)

    Thuy, N. N. Q.

    2006-01-01

    Inappropriately designed inter-channel and inter-system digital communications could initiate common cause failure of multiple channels or multiple systems. Defensive measures were introduced in EPRI report TR-1002835 (Guideline for Performing Defense-in-Depth and Diversity Assessments for Digital Upgrades) to assess, on a deterministic basis, the susceptibility of digital systems architectures to common-cause failures. This paper suggests how this approach could be applied to assess inter-channel and inter-system digital communications from a safety standpoint. The first step of the approach is to systematically identify the so called 'influence factors' that one end of the data communication path can have on the other. Potential factors to be considered would typically include data values, data volumes and data rates. The second step of the approach is to characterize the ways possible failures of a given end of the communication path could affect these influence factors (e.g., incorrect data values, excessive data rates, time-outs, incorrect data volumes). The third step is to analyze the designed-in measures taken to guarantee independence of the other end. In addition to classical error detection and correction codes, typical defensive measures are one-way data communication, fixed-rate data communication, fixed-volume data communication, validation of data values. (authors)

  17. Accurate and cost-effective MTF measurement system for lens modules of digital cameras

    Science.gov (United States)

    Chang, Gao-Wei; Liao, Chia-Cheng; Yeh, Zong-Mu

    2007-01-01

    For many years, the widening use of digital imaging products, e.g., digital cameras, has given rise to much attention in the market of consumer electronics. However, it is important to measure and enhance the imaging performance of the digital ones, compared to that of conventional cameras (with photographic films). For example, the effect of diffraction arising from the miniaturization of the optical modules tends to decrease the image resolution. As a figure of merit, modulation transfer function (MTF) has been broadly employed to estimate the image quality. Therefore, the objective of this paper is to design and implement an accurate and cost-effective MTF measurement system for the digital camera. Once the MTF of the sensor array is provided, that of the optical module can be then obtained. In this approach, a spatial light modulator (SLM) is employed to modulate the spatial frequency of light emitted from the light-source. The modulated light going through the camera under test is consecutively detected by the sensors. The corresponding images formed from the camera are acquired by a computer and then, they are processed by an algorithm for computing the MTF. Finally, through the investigation on the measurement accuracy from various methods, such as from bar-target and spread-function methods, it appears that our approach gives quite satisfactory results.

  18. Development of reconfigurable analog and digital circuits for plasma diagnostics measurement systems

    International Nuclear Information System (INIS)

    Srivastava, Amit Kumar; Sharma, Atish; Raval, Tushar

    2009-01-01

    In long pulse discharge tokamak, a large number of diagnostic channels are being used to understand the complex behavior of plasma. Different diagnostics demand different types of analog and digital processing for plasma parameters measurement. This leads to variable requirements of signal processing for diagnostic measurement. For such types of requirements, we have developed hardware with reconfigurable electronic devices, which provide flexible solution for rapid development of measurement system. Here the analog processing is achieved by Field Programmable Analog Array (FPAA) integrated circuit while reconfigurable digital devices (CPLD/FPGA) achieve digital processing. FPAA's provide an ideal integrated platform for implementing low to medium complexity analog signal processing. With dynamic reconfigurability, the functionality of the FPAA can be reconfigured in-system by the designer or on the fly by a microprocessor. This feature is quite useful to manipulate the tuning or the construction of any part of the analog circuit without interrupting operation of the FPAA, thus maintaining system integrity. The hardware operation control logic circuits are configured in the reconfigurable digital devices (CPLD/FPGA) to control proper hardware functioning. These reconfigurable devices provide the design flexibility and save the component space on the board. It also provides the flexibility for various setting through software. The circuit controlling commands are either issued by computer/processor or generated by circuit itself. (author)

  19. Temperature sensitivity study of eddy current and digital gauge probes for nuclear fuel rod oxide measurement

    Science.gov (United States)

    Beck, Faith R.; Lind, R. Paul; Smith, James A.

    2018-04-01

    Novel fuels are part of the nationwide effort to reduce the enrichment of Uranium for energy production. Performance of such fuels is determined by irradiating their surfaces. To test irradiated samples, the instrumentation must operate remotely. The plate checker used in this experiment at Idaho National Lab (INL) performs non-destructive testing on fuel rod and plate geometries with two different types of sensors: eddy current and digital thickness gauges. The sensors measure oxide growth and total sample thickness on research fuels, respectively. Sensor measurement accuracy is crucial because even 10 microns of error is significant when determining the viability of an experimental fuel. One parameter known to affect the eddy current and thickness gauge sensors is temperature. Since both sensor accuracies depend on the ambient temperature of the system, the plate checker has been characterized for these sensitivities. The manufacturer of the digital gauge probes has noted a rather large coefficient of thermal expansion for their linear scale. It should also be noted that the accuracy of the digital gauge probes are specified at 20°C, which is approximately 7°C cooler than the average hot-cell temperature. In this work, the effect of temperature on the eddy current and digital gauge probes is studied, and thickness measurements are given as empirical functions of temperature.

  20. Final report on COOMET.EM-S11: Supplementary bilateral comparison of the measurement of current transformers between UNIIM and PTB

    Science.gov (United States)

    Mohns, Enrico; Sychev, Y.; Roeissle, G.

    2014-01-01

    A bilateral comparison of the measurement of current transformers was carried out between UNIIM (Russia) and PTB (Germany). For all of the current ratio error measurements and the phase displacement measurements there is a close agreement between PTB and UNIIM. Extensive measurements with the travelling standards were carried out at 18 different current ratios and at 5 different test points (1%, 5%, 20%, 100% and 120%) each. The range of tested primary currents was from 10 mA to 60 kA. It can therefore be concluded that the results of each laboratory agree very well within the calculated measurement uncertainties. No outliers were observed. Considering especially the En factors, the calculated uncertainties seem to be too conservative to some extent. Here there is the possibility to slightly improve the uncertainty budgets in the future if there is a need. The worst En factors are within ±0.6 at 1 kA/5 A and ±0.8 at 3 kA. The current comparator 'IW 32' from PTB may have caused that. This was subsequently confirmed. The primary current induced a small voltage in the compensation winding. This problem has now been solved. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  1. A longitudinal study of the bilateral benefit in children with bilateral cochlear implants.

    Science.gov (United States)

    Asp, Filip; Mäki-Torkko, Elina; Karltorp, Eva; Harder, Henrik; Hergils, Leif; Eskilsson, Gunnar; Stenfelt, Stefan

    2015-02-01

    To study the development of the bilateral benefit in children using bilateral cochlear implants by measurements of speech recognition and sound localization. Bilateral and unilateral speech recognition in quiet, in multi-source noise, and horizontal sound localization was measured at three occasions during a two-year period, without controlling for age or implant experience. Longitudinal and cross-sectional analyses were performed. Results were compared to cross-sectional data from children with normal hearing. Seventy-eight children aged 5.1-11.9 years, with a mean bilateral cochlear implant experience of 3.3 years and a mean age of 7.8 years, at inclusion in the study. Thirty children with normal hearing aged 4.8-9.0 years provided normative data. For children with cochlear implants, bilateral and unilateral speech recognition in quiet was comparable whereas a bilateral benefit for speech recognition in noise and sound localization was found at all three test occasions. Absolute performance was lower than in children with normal hearing. Early bilateral implantation facilitated sound localization. A bilateral benefit for speech recognition in noise and sound localization continues to exist over time for children with bilateral cochlear implants, but no relative improvement is found after three years of bilateral cochlear implant experience.

  2. Bilateral herpes zoster

    Directory of Open Access Journals (Sweden)

    Singh K

    1993-01-01

    Full Text Available A case of bilateral herpes zoster of lumbosacral region is reported in association with diabetes mellitus in a 55 years old female. The case is of interest due to bilateral distribution which is rare and sacral region involvement which is quite uncommon.

  3. Bilateral herpes zoster

    OpenAIRE

    Singh K; Bajaj A; Dwivedi N; Merchery A

    1993-01-01

    A case of bilateral herpes zoster of lumbosacral region is reported in association with diabetes mellitus in a 55 years old female. The case is of interest due to bilateral distribution which is rare and sacral region involvement which is quite uncommon.

  4. The Accuracy and Reproducibility of Linear Measurements Made on CBCT-derived Digital Models.

    Science.gov (United States)

    Maroua, Ahmad L; Ajaj, Mowaffak; Hajeer, Mohammad Y

    2016-04-01

    To evaluate the accuracy and reproducibility of linear measurements made on cone-beam computed tomography (CBCT)-derived digital models. A total of 25 patients (44% female, 18.7 ± 4 years) who had CBCT images for diagnostic purposes were included. Plaster models were obtained and digital models were extracted from CBCT scans. Seven linear measurements from predetermined landmarks were measured and analyzed on plaster models and the corresponding digital models. The measurements included arch length and width at different sites. Paired t test and Bland-Altman analysis were used to evaluate the accuracy of measurements on digital models compared to the plaster models. Also, intraclass correlation coefficients (ICCs) were used to evaluate the reproducibility of the measurements in order to assess the intraobserver reliability. The statistical analysis showed significant differences on 5 out of 14 variables, and the mean differences ranged from -0.48 to 0.51 mm. The Bland-Altman analysis revealed that the mean difference between variables was (0.14 ± 0.56) and (0.05 ± 0.96) mm and limits of agreement between the two methods ranged from -1.2 to 0.96 and from -1.8 to 1.9 mm in the maxilla and the mandible, respectively. The intraobserver reliability values were determined for all 14 variables of two types of models separately. The mean ICC value for the plaster models was 0.984 (0.924-0.999), while it was 0.946 for the CBCT models (range from 0.850 to 0.985). Linear measurements obtained from the CBCT-derived models appeared to have a high level of accuracy and reproducibility.

  5. Bilateral Medial Medullary Infarction with Nondominant Vertebral Artery Occlusion.

    Science.gov (United States)

    Zhang, Lei; Zhang, Gui-lian; Du, Ju-mei; Ma, Zhu-lin

    2015-09-01

    Bilateral medial medullary infarction (MMI) is a rare stroke subtype. Here, we report a case with bilateral MMI caused by nondominant vertebral artery occlusion confirmed by brain digital subtraction angiography and magnetic resonance imaging basi-parallel-anatomical-scanning. We highlight that anterior spinal arteries could originate from a unilateral vertebral artery (VA). Radiologists and neurologists should pay attention to the nondominant VA as bilateral MMI may be induced by occlusion of nondominant VA that supplies the bilateral anteromedial territories of the medulla. Copyright © 2015 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  6. Easy Leaf Area: Automated digital image analysis for rapid and accurate measurement of leaf area.

    Science.gov (United States)

    Easlon, Hsien Ming; Bloom, Arnold J

    2014-07-01

    Measurement of leaf areas from digital photographs has traditionally required significant user input unless backgrounds are carefully masked. Easy Leaf Area was developed to batch process hundreds of Arabidopsis rosette images in minutes, removing background artifacts and saving results to a spreadsheet-ready CSV file. • Easy Leaf Area uses the color ratios of each pixel to distinguish leaves and calibration areas from their background and compares leaf pixel counts to a red calibration area to eliminate the need for camera distance calculations or manual ruler scale measurement that other software methods typically require. Leaf areas estimated by this software from images taken with a camera phone were more accurate than ImageJ estimates from flatbed scanner images. • Easy Leaf Area provides an easy-to-use method for rapid measurement of leaf area and nondestructive estimation of canopy area from digital images.

  7. Easy Leaf Area: Automated Digital Image Analysis for Rapid and Accurate Measurement of Leaf Area

    Directory of Open Access Journals (Sweden)

    Hsien Ming Easlon

    2014-07-01

    Full Text Available Premise of the study: Measurement of leaf areas from digital photographs has traditionally required significant user input unless backgrounds are carefully masked. Easy Leaf Area was developed to batch process hundreds of Arabidopsis rosette images in minutes, removing background artifacts and saving results to a spreadsheet-ready CSV file. Methods and Results: Easy Leaf Area uses the color ratios of each pixel to distinguish leaves and calibration areas from their background and compares leaf pixel counts to a red calibration area to eliminate the need for camera distance calculations or manual ruler scale measurement that other software methods typically require. Leaf areas estimated by this software from images taken with a camera phone were more accurate than ImageJ estimates from flatbed scanner images. Conclusions: Easy Leaf Area provides an easy-to-use method for rapid measurement of leaf area and nondestructive estimation of canopy area from digital images.

  8. Digital Moiré based transient interferometry and its application in optical surface measurement

    Science.gov (United States)

    Hao, Qun; Tan, Yifeng; Wang, Shaopu; Hu, Yao

    2017-10-01

    Digital Moiré based transient interferometry (DMTI) is an effective non-contact testing methods for optical surfaces. In DMTI system, only one frame of real interferogram is experimentally captured for the transient measurement of the surface under test (SUT). When combined with partial compensation interferometry (PCI), DMTI is especially appropriate for the measurement of aspheres with large apertures, large asphericity or different surface parameters. Residual wavefront is allowed in PCI, so the same partial compensator can be applied to the detection of multiple SUTs. Excessive residual wavefront aberration results in spectrum aliasing, and the dynamic range of DMTI is limited. In order to solve this problem, a method based on wavelet transform is proposed to extract phase from the fringe pattern with spectrum aliasing. Results of simulation demonstrate the validity of this method. The dynamic range of Digital Moiré technology is effectively expanded, which makes DMTI prospective in surface figure error measurement for intelligent fabrication of aspheric surfaces.

  9. Measurement facilities and accuracy limits of sampling digital interferometers. Meresi lehetoesegek es hibaanalizis digitalis mintavetelezoe interferometeren

    Energy Technology Data Exchange (ETDEWEB)

    Czitrovszky, A.; Jani, P.; Szoter, L.

    1990-12-15

    We discuss the measurement facilities of a recently development sampling digital interferometer for machine tool testing. As opposed to conventional interferometers the present device provides possibilities for the digital storage up to 4 kHz of the complete information of the motion so that displacement, velocity, acceleration and power density spectrum measurement can be performed. An estimation is given for the truncation, round-off, jitter and frequency-aliasing sources of error of the reconstructed motion parameters. On the basis of the Shannon sampling theory optimal conditions of measurement parameters are defined for the case when the accuracy of the reconstructed part of motion and vibration is equal to the resolution of the conventional interferometer. 7 refs., 3 figs., 1 tab.

  10. Measurement of in-plane strain with dual beam spatial phase-shift digital shearography

    International Nuclear Information System (INIS)

    Xie, Xin; Chen, Xu; Li, Junrui; Yang, Lianxiang; Wang, Yonghong

    2015-01-01

    Full-field in-plane strain measurement under dynamic loading by digital shearography remains a big challenge in practice. A phase measurement for in-plane strain information within one time frame has to be achieved to solve this problem. This paper presents a dual beam spatial phase-shift digital shearography system with the capacity to measure phase distribution corresponding to in-plane strain information within a single time frame. Two laser beams with different wavelengths are symmetrically arranged to illuminate the object under test, and two cameras with corresponding filters, which enable simultaneous recording of two shearograms, are utilized for data acquisition. The phase information from the recorded shearograms, which corresponds to the in-plane strain, is evaluated by the spatial phase-shift method. The spatial phase-shift shearography system realizes a measurement of the in-plane strain through the introduction of the spatial phase-shift technique, using one frame after the loading and one frame before loading. This paper presents the theory of the spatial phase-shift digital shearography for in-plane strain measurement and its derivation, experimental results, and the technique’s potential. (paper)

  11. Digital radiography density measurements in differentiation between periapical granulomas and radicular cysts.

    Science.gov (United States)

    Rózyło-Kalinowska, Ingrid

    2007-05-01

    The distinction between radicular cysts and apical granulomas is a matter of considerable importance in making a treatment decision. Because there are no clearly defined radiographic criteria, the distinction is made on the grounds of size. However, it has been suggested that cysts can be distinguished from granulomas on the basis of their radiometric density. The results of previous studies have proved conflicting. To determine possibilities of application of digital radiography density measurements in differentiation of periapical granulomas and radicular cysts of inflammatory origin. The material consisted of 355 digital periapical radiograms obtained using Digora, RVG and Dixi 2 digital radiography systems in patients aged 20 to 84, divided into two groups: 259 granulomas and 102 radicular cysts. By means of Digora 2.0 software there were measured maximum and minimum densities along a line, then there was calculated the difference between maximum and minimum density. The largest dimensions of the lesions were measured - perpendicular and parallel to the root canal axis. It was proved that to some extent it was possible to differentiate cystic granulomas and radicular cysts on the basis of the difference between maximum and minimum density in linear measurement - when the difference exceeded 85.6 the lesion was a cyst and when it was below 45.9 a granuloma was diagnosed. Combination of two criteria - the calculated difference between densities and the largest dimension of a lesion, increased diagnostic possibilities of radiological differentiation of granulomas and radicular cysts.

  12. [Bilateral cochlear implants].

    Science.gov (United States)

    Müller, J

    2017-07-01

    Cochlear implants (CI) are standard for the hearing rehabilitation of severe to profound deafness. Nowadays, if bilaterally indicated, bilateral implantation is usually recommended (in accordance with German guidelines). Bilateral implantation enables better speech discrimination in quiet and in noise, and restores directional and spatial hearing. Children with bilateral CI are able to undergo hearing-based hearing and speech development. Within the scope of their individual possibilities, bilaterally implanted children develop faster than children with unilateral CI and attain, e.g., a larger vocabulary within a certain time interval. Only bilateral implantation allows "binaural hearing," with all the benefits that people with normal hearing profit from, namely: better speech discrimination in quiet and in noise, as well as directional and spatial hearing. Naturally, the developments take time. Binaural CI users benefit from the same effects as normal hearing persons: head shadow effect, squelch effect, and summation and redundancy effects. Sequential CI fitting is not necessarily disadvantageous-both simultaneously and sequentially fitted patients benefit in a similar way. For children, earliest possible fitting and shortest possible interval between the two surgeries seems to positively influence the outcome if bilateral CI are indicated.

  13. Advanced measurement systems based on digital processing techniques for superconducting LHC magnets

    CERN Document Server

    Masi, Alessandro; Cennamo, Felice

    The Large Hadron Collider (LHC), a particle accelerator aimed at exploring deeper into matter than ever before, is currently being constructed at CERN. Beam optics of the LHC, requires stringent control of the field quality of about 8400 superconducting magnets, including 1232 main dipoles and 360 main quadrupoles to assure the correct machine operation. The measurement challenges are various: accuracy on the field strength measurement up to 50 ppm, harmonics in the ppm range, measurement equipment robustness, low measurement times to characterize fast field phenomena. New magnetic measurement systems, principally based on analog solutions, have been developed at CERN to achieve these goals. This work proposes the introduction of digital technologies to improve measurement performance of three systems, aimed at different measurement target and characterized by different accuracy levels. The high accuracy measurement systems, based on rotating coils, exhibit high performance in static magnetic field. With vary...

  14. Pregnancy following bilateral salpingectomy

    DEFF Research Database (Denmark)

    Oturai, Annette Bang

    2008-01-01

    This report presents a rare case of spontaneous pregnancy following bilateral salpingectomy. A woman with a history of bilateral salpingectomy was admitted to hospital because of abdominal pain and positive urine HCG. Surprisingly, ultrasound confirmed a live intrauterine fetus. The pregnancy...... was unwanted, and the woman decided to terminate the pregnancy. She was offered diagnostic examination to localise a potential fistula, but she declined. In a MEDLINE search of English literature this is only the second case of spontaneous pregnancy following bilateral salpingectomy Udgivelsesdato: 2008/4/21...

  15. Measuring the global information society - explaining digital inequality by economic level and education standard

    Science.gov (United States)

    Ünver, H.

    2017-02-01

    A main focus of this research paper is to investigate on the explanation of the ‘digital inequality’ or ‘digital divide’ by economic level and education standard of about 150 countries worldwide. Inequality regarding GDP per capita, literacy and the so-called UN Education Index seem to be important factors affecting ICT usage, in particular Internet penetration, mobile phone usage and also mobile Internet services. Empirical methods and (multivariate) regression analysis with linear and non-linear functions are useful methods to measure some crucial factors of a country or culture towards becoming information and knowledge based society. Overall, the study concludes that the convergence regarding ICT usage proceeds worldwide faster than the convergence in terms of economic wealth and education in general. The results based on a large data analysis show that the digital divide is declining over more than a decade between 2000 and 2013, since more people worldwide use mobile phones and the Internet. But a high digital inequality explained to a significant extent by the functional relation between technology penetration rates, education level and average income still exists. Furthermore it supports the actions of countries at UN/G20/OECD level for providing ICT access to all people for a more balanced world in context of sustainable development by postulating that policymakers need to promote comprehensive education worldwide by means of using ICT.

  16. Uncertainty Reduction Via Parameter Design of A Fast Digital Integrator for Magnetic Field Measurement

    CERN Document Server

    Arpaia, P; Lucariello, G; Spiezia, G

    2007-01-01

    At European Centre of Nuclear Research (CERN), within the new Large Hadron Collider (LHC) project, measurements of magnetic flux with uncertainty of 10 ppm at a few of decades of Hz for several minutes are required. With this aim, a new Fast Digital Integrator (FDI) has been developed in cooperation with University of Sannio, Italy [1]. This paper deals with the final design tuning for achieving target uncertainty by means of experimental statistical parameter design.

  17. Measurement of the traction force of biological cells by digital holography

    Science.gov (United States)

    Yu, Xiao; Cross, Michael; Liu, Changgeng; Clark, David C.; Haynie, Donald T.; Kim, Myung K.

    2011-01-01

    The traction force produced by biological cells has been visualized as distortions in flexible substrata. We have utilized quantitative phase microscopy by digital holography (DH-QPM) to study the wrinkling of a silicone rubber film by motile fibroblasts. Surface deformation and the cellular traction force have been measured from phase profiles in a direct and straightforward manner. DH-QPM is shown to provide highly efficient and versatile means for quantitatively analyzing cellular motility. PMID:22254175

  18. Acute inflammation induces segmental, bilateral, supraspinally mediated opioid release in the rat spinal cord, as measured by μ-opioid receptor internalization

    Science.gov (United States)

    Chen, Wenling; Marvizón, Juan Carlos G.

    2009-01-01

    The objective of this study was to measure opioid release in the spinal cord during acute and long-term inflammation using μ-opioid receptor (MOR) internalization. In particular, we determined whether opioid release occurs in the segments receiving the noxious signals or in the entire spinal cord, and whether it involves supraspinal signals. Internalization of neurokinin 1 receptors (NK1Rs) was measured to track the intensity of the noxious stimulus. Rats received peptidase inhibitors intrathecally to protect opioids from degradation. Acute inflammation of the hindpaw with formalin induced moderate MOR internalization in the L5 segment bilaterally, whereas NK1R internalization occurred only ipsilaterally. MOR internalization was restricted to the lumbar spinal cord, regardless of whether the peptidase inhibitors were injected in a lumbar or thoracic site. Formalin-induced MOR internalization was substantially reduced by isoflurane anesthesia. It was also markedly reduced by a lidocaine block of the cervical-thoracic spinal cord (which did not affect the evoked NK1R internalization) indicating that spinal opioid release is mediated supraspinally. In the absence of peptidase inhibitors, formalin and hindpaw clamp induced a small amount of MOR internalization, which was significantly higher than in controls. To study spinal opioid release during chronic inflammation, we injected Complete Freund's Adjuvant (CFA) in the hindpaw and peptidase inhibitors intrathecally. Two days later, no MOR or NK1R internalization was detected. Furthermore, CFA inflammation decreased MOR internalization induced by clamping the inflamed hindpaw. These results show that acute inflammation, but not chronic inflammation, induce segmental opioid release in the spinal cord that involves supraspinal signals. PMID:19298846

  19. Acute inflammation induces segmental, bilateral, supraspinally mediated opioid release in the rat spinal cord, as measured by mu-opioid receptor internalization.

    Science.gov (United States)

    Chen, W; Marvizón, J C G

    2009-06-16

    The objective of this study was to measure opioid release in the spinal cord during acute and long-term inflammation using mu-opioid receptor (MOR) internalization. In particular, we determined whether opioid release occurs in the segments receiving the noxious signals or in the entire spinal cord, and whether it involves supraspinal signals. Internalization of neurokinin 1 receptors (NK1Rs) was measured to track the intensity of the noxious stimulus. Rats received peptidase inhibitors intrathecally to protect opioids from degradation. Acute inflammation of the hind paw with formalin induced moderate MOR internalization in the L5 segment bilaterally, whereas NK1R internalization occurred only ipsilaterally. MOR internalization was restricted to the lumbar spinal cord, regardless of whether the peptidase inhibitors were injected in a lumbar or thoracic site. Formalin-induced MOR internalization was substantially reduced by isoflurane anesthesia. It was also markedly reduced by a lidocaine block of the cervical-thoracic spinal cord (which did not affect the evoked NK1R internalization) indicating that spinal opioid release is mediated supraspinally. In the absence of peptidase inhibitors, formalin and hind paw clamp induced a small amount of MOR internalization, which was significantly higher than in controls. To study spinal opioid release during chronic inflammation, we injected complete Freund's adjuvant (CFA) in the hind paw and peptidase inhibitors intrathecally. Two days later, no MOR or NK1R internalization was detected. Furthermore, CFA inflammation decreased MOR internalization induced by clamping the inflamed hind paw. These results show that acute inflammation, but not chronic inflammation, induces segmental opioid release in the spinal cord that involves supraspinal signals.

  20. A fast continuous magnetic field measurement system based on digital signal processors

    Energy Technology Data Exchange (ETDEWEB)

    Velev, G.V.; Carcagno, R.; DiMarco, J.; Kotelnikov, S.; Lamm, M.; Makulski, A.; /Fermilab; Maroussov, V.; /Purdue U.; Nehring, R.; Nogiec, J.; Orris, D.; /Fermilab; Poukhov,; Prakoshyn, F.; /Dubna, JINR; Schlabach, P.; Tompkins, J.C.; /Fermilab

    2005-09-01

    In order to study dynamic effects in accelerator magnets, such as the decay of the magnetic field during the dwell at injection and the rapid so-called ''snapback'' during the first few seconds of the resumption of the energy ramp, a fast continuous harmonics measurement system was required. A new magnetic field measurement system, based on the use of digital signal processors (DSP) and Analog to Digital (A/D) converters, was developed and prototyped at Fermilab. This system uses Pentek 6102 16 bit A/D converters and the Pentek 4288 DSP board with the SHARC ADSP-2106 family digital signal processor. It was designed to acquire multiple channels of data with a wide dynamic range of input signals, which are typically generated by a rotating coil probe. Data acquisition is performed under a RTOS, whereas processing and visualization are performed under a host computer. Firmware code was developed for the DSP to perform fast continuous readout of the A/D FIFO memory and integration over specified intervals, synchronized to the probe's rotation in the magnetic field. C, C++ and Java code was written to control the data acquisition devices and to process a continuous stream of data. The paper summarizes the characteristics of the system and presents the results of initial tests and measurements.

  1. A fast continuous magnetic field measurement system based on digital signal processors

    International Nuclear Information System (INIS)

    Velev, G.V.; Carcagno, R.; DiMarco, J.; Kotelnikov, S.; Lamm, M.; Makulski, A.; Maroussov, V.; Nehring, R.; Nogiec, J.; Orris, D.; Poukhov, O.; Prakoshyn, F.; Schlabach, P.; Tompkins, J.C.

    2005-01-01

    In order to study dynamic effects in accelerator magnets, such as the decay of the magnetic field during the dwell at injection and the rapid so-called ''snapback'' during the first few seconds of the resumption of the energy ramp, a fast continuous harmonics measurement system was required. A new magnetic field measurement system, based on the use of digital signal processors (DSP) and Analog to Digital (A/D) converters, was developed and prototyped at Fermilab. This system uses Pentek 6102 16 bit A/D converters and the Pentek 4288 DSP board with the SHARC ADSP-2106 family digital signal processor. It was designed to acquire multiple channels of data with a wide dynamic range of input signals, which are typically generated by a rotating coil probe. Data acquisition is performed under a RTOS, whereas processing and visualization are performed under a host computer. Firmware code was developed for the DSP to perform fast continuous readout of the A/D FIFO memory and integration over specified intervals, synchronized to the probe's rotation in the magnetic field. C, C++ and Java code was written to control the data acquisition devices and to process a continuous stream of data. The paper summarizes the characteristics of the system and presents the results of initial tests and measurements

  2. Digital Divide in India: Measurement, Determinants and Policy for Addressing the Challenges in Bridging the Digital Divide

    OpenAIRE

    Sumanjeet Singh

    2010-01-01

    Existing studies of the digital divide reveals the gap that exists between those who have access to ICTs and those who do not create exclusion, endanger social integration and hamper economic growth. The digital divide has many dimensions and can be categorized as global, regional and national. At national level, there is no single divide, but multiple divides: for instance, within countries, between men and women, young and elderly, rich and poor and most importantly rural and urban. The pre...

  3. Influence of Wilbraham-Gibbs Phenomenon on Digital Stochastic Measurement of EEG Signal Over an Interval

    Directory of Open Access Journals (Sweden)

    Sovilj P.

    2014-10-01

    Full Text Available Measurement methods, based on the approach named Digital Stochastic Measurement, have been introduced, and several prototype and small-series commercial instruments have been developed based on these methods. These methods have been mostly investigated for various types of stationary signals, but also for non-stationary signals. This paper presents, analyzes and discusses digital stochastic measurement of electroencephalography (EEG signal in the time domain, emphasizing the problem of influence of the Wilbraham-Gibbs phenomenon. The increase of measurement error, related to the Wilbraham-Gibbs phenomenon, is found. If the EEG signal is measured and measurement interval is 20 ms wide, the average maximal error relative to the range of input signal is 16.84 %. If the measurement interval is extended to 2s, the average maximal error relative to the range of input signal is significantly lowered - down to 1.37 %. Absolute errors are compared with the error limit recommended by Organisation Internationale de Métrologie Légale (OIML and with the quantization steps of the advanced EEG instruments with 24-bit A/D conversion

  4. Research on Damage Identification of Bridge Based on Digital Image Measurement

    Science.gov (United States)

    Liang, Yingjing; Huan, Shi; Tao, Weijun

    2017-12-01

    In recent years, the number of the damage bridge due to excessive deformation gradually increased, which caused significant property damage and casualties. Hence health monitoring and the damage detection of the bridge structure based on the deflection measurement are particularly important. The current conventional deflection measurement methods, such as total station, connected pipe, GPS, etc., have many shortcomings as low efficiency, heavy workload, low degree of automation, operating frequency and working time constrained. GPS has a low accuracy in the vertical displacement measurement and cannot meet the dynamic measured requirements of the current bridge engineering. This paper presents a bridge health monitoring and damage detection technology based on digital image measurement method in which the measurement accuracy is sub-millimeter level and can achieve the 24-hour automatic non-destructive monitoring for the deflection. It can be concluded from this paper that it is feasible to use digital image measurement method for identification of the damage in the bridge structure, because it has been validated by the theoretical analysis, the laboratory model and the application of the real bridge.

  5. Application of Digital Image Correlation to Measurement of Packaging Material Mechanical Properties

    Directory of Open Access Journals (Sweden)

    Jian-Wei Zhou

    2013-01-01

    Full Text Available Among various packaging materials, papers and polymer plastics are the most common due to their light weights, low costs, and other advantages. However, their mechanical properties are difficult to measure precisely because of their softness. To overcome the difficulty, a new measure instrument prototype is proposed based on an optical method known as the digital image correlation (DIC. Experiments are designed to apply the DIC to measure mechanical properties of flexible packaging materials, including the stress-strain relationship, the Poisson ratio, the coefficient of heat expansion, the creep deformation, and the top-pressure deformation of corrugated box. In addition, the low frequency vibration of package is simulated, and the vibration frequencies are measured by DIC. Results obtained in the experiments illustrate the advantages of the DIC over traditional methods: noncontact, no reinforced effect, high precision over entire area, wide measurement range, and good measurement stability.

  6. Precise measurement of cat patellofemoral joint surface geometry with multistation digital photogrammetry.

    Science.gov (United States)

    Ronsky, J L; Boyd, S K; Lichti, D D; Chapman, M A; Salkauskas, K

    1999-04-01

    Three-dimensional joint models are important tools for investigating mechanisms related to normal and pathological joints. Often these models necessitate accurate three-dimensional joint surface geometric data so that reliable model results can be obtained; however, in models based on small joints, this is often problematic due to limitations of the present techniques. These limitations include insufficient measurement precision the requirement of contact for the measurement process, and lack of entire joint description. This study presents a new non-contact method for precise determination of entire joint surfaces using multistation digital photogrammetry (MDPG) and is demonstrated by determining the cartilage and subchondral bone surfaces of the cat patellofemoral (PF) joint. The digital camera-lens setup was precisely calibrated using 16 photographs arranged to achieve highly convergent geometry to estimate interior and distortion parameters of the camera-lens setup. Subsequently, six photographs of each joint surface were then acquired for surface measurement. The digital images were directly imported to a computer and newly introduced semi-automatic computer algorithms were used to precisely determine the image coordinates. Finally, a rigorous mathematical procedure named the bundle adjustment was used to determine the three-dimensional coordinates of the joint surfaces and to estimate the precision of the coordinates. These estimations were validated by comparing the MDPG measurements of a cylinder and plane to an analytical model. The joint surfaces were successfully measured using the MDPG method with mean precision estimates in the least favorable coordinate direction being 10.3 microns for subchondral bone and 17.9 microns for cartilage. The difference in measurement precision for bone and cartilage primarily reflects differences in the translucent properties of the surfaces.

  7. Measurement-Device Independency Analysis of Continuous-Variable Quantum Digital Signature

    Directory of Open Access Journals (Sweden)

    Tao Shang

    2018-04-01

    Full Text Available With the practical implementation of continuous-variable quantum cryptographic protocols, security problems resulting from measurement-device loopholes are being given increasing attention. At present, research on measurement-device independency analysis is limited in quantum key distribution protocols, while there exist different security problems for different protocols. Considering the importance of quantum digital signature in quantum cryptography, in this paper, we attempt to analyze the measurement-device independency of continuous-variable quantum digital signature, especially continuous-variable quantum homomorphic signature. Firstly, we calculate the upper bound of the error rate of a protocol. If it is negligible on condition that all measurement devices are untrusted, the protocol is deemed to be measurement-device-independent. Then, we simplify the calculation by using the characteristics of continuous variables and prove the measurement-device independency of the protocol according to the calculation result. In addition, the proposed analysis method can be extended to other quantum cryptographic protocols besides continuous-variable quantum homomorphic signature.

  8. Measuring the nanomechanical properties of cancer cells by digital pulsed force mode imaging

    International Nuclear Information System (INIS)

    Marti, Othmar; Holzwarth, Michael; Beil, Michael

    2008-01-01

    In this paper, we demonstrate that the digital pulsed force mode data can distinguish two cancer cell lines (HeLa, Panc) by their mechanical properties. The live cells were imaged in buffer solution. The digital pulsed force mode measured 175 force-distance curves per second which, due to the speed of the measurement, were distorted by the viscous drag in the buffer. We show that this drag force causes a sinusoidal addition to the force-distance curves. By subtracting the viscous drag effect one obtains standard force-distance curves. The force-distance curves are then evaluated to extract key data on the curves, such as adhesion energies, local stiffness or the width of the hysteresis loop. These data are then correlated to classify the force-distance curves. We show examples based on the width of the hysteresis loop and the adhesion energies. Outliers in this classification scheme are points where, potentially, interesting new physics or different physics might happen. Based on classification schemes adapted to experimental settings, we propose that the digital pulsed force mode is a tool to evaluate the time evolution of the mechanical response of cells

  9. Measuring the nanomechanical properties of cancer cells by digital pulsed force mode imaging

    Energy Technology Data Exchange (ETDEWEB)

    Marti, Othmar; Holzwarth, Michael [Institute of Experimental Physics, Ulm University, D-89069 Ulm (Germany); Beil, Michael [Department of Internal Medicine, Ulm University, D-89069 Ulm (Germany)], E-mail: othmar.marti@uni-ulm.de, E-mail: michael.holzwarth@uni-ulm.de, E-mail: michael.beil@uni-ulm.de

    2008-09-24

    In this paper, we demonstrate that the digital pulsed force mode data can distinguish two cancer cell lines (HeLa, Panc) by their mechanical properties. The live cells were imaged in buffer solution. The digital pulsed force mode measured 175 force-distance curves per second which, due to the speed of the measurement, were distorted by the viscous drag in the buffer. We show that this drag force causes a sinusoidal addition to the force-distance curves. By subtracting the viscous drag effect one obtains standard force-distance curves. The force-distance curves are then evaluated to extract key data on the curves, such as adhesion energies, local stiffness or the width of the hysteresis loop. These data are then correlated to classify the force-distance curves. We show examples based on the width of the hysteresis loop and the adhesion energies. Outliers in this classification scheme are points where, potentially, interesting new physics or different physics might happen. Based on classification schemes adapted to experimental settings, we propose that the digital pulsed force mode is a tool to evaluate the time evolution of the mechanical response of cells.

  10. Correlation between the physical performances measured from detectors and the diagnostic image quality in digital mammography

    International Nuclear Information System (INIS)

    Perez-Ponce, H.

    2009-05-01

    In digital mammography two approaches exist to estimate image quality. In the first approach, human observer assesses the lesion detection in mammograms. Unfortunately, such quality assessment is subject to interobserver variability, and requires a large amount of time and human resources. In the second approach, objective and human-independent parameters relating to image spatial resolution and noise (MTF and NPS) are used to evaluate digital detector performance; even if these parameters are objective, they are not directly related to lesion detection. A method leading to image quality assessment which is both human independent, and directly related to lesion detection is very important for the optimal use of mammographic units. This Ph.D thesis presents the steps towards such a method: the computation of realistic virtual images using an 'X ray source/digital detector' model taking into account the physical parameters of the detector (spatial resolution and noise measurements) measured under clinical conditions. From results obtained in this work, we have contributed to establish the link between the physical characteristics of detectors and the clinical quality of the image for usual exposition conditions. Furthermore, we suggest the use of our model for the creation of virtual images, in order to rapidly determine the optimal conditions in mammography, which usually is a long and tedious experimental process. This is an essential aspect to be taken into account for radioprotection of patients, especially in the context of organized mass screening of breast cancer. (author)

  11. Measurements of timing resolution of ultra-fast silicon detectors with the SAMPIC waveform digitizer

    Energy Technology Data Exchange (ETDEWEB)

    Breton, D. [CNRS/IN2P3/LAL Orsay, Université Paris-Saclay, F-91898 Orsay (France); De Cacqueray, V.; Delagnes, E. [IRFU, CEA, Université Paris-Saclay, F-91191 Gif-sur-Yvette (France); Grabas, H. [Santa Cruz Institute for Particle Physics UC Santa Cruz, CA 95064 (United States); Maalmi, J. [CNRS/IN2P3/LAL Orsay, Université Paris-Saclay, F-91898 Orsay (France); Minafra, N. [Dipartimento Interateneo di Fisica di Bari, Bari (Italy); CERN, Geneva (Switzerland); Royon, C. [University of Kansas, Lawrence (United States); Saimpert, M., E-mail: matthias.saimpert@cern.ch [IRFU, CEA, Université Paris-Saclay, F-91191 Gif-sur-Yvette (France)

    2016-11-01

    The SAMpler for PICosecond time (SAMPIC) chip has been designed by a collaboration including CEA/IRFU/SEDI, Saclay and CNRS/LAL/SERDI, Orsay. It benefits from both the quick response of a time to digital converter and the versatility of a waveform digitizer to perform accurate timing measurements. Thanks to the sampled signals, smart algorithms making best use of the pulse shape can be used to improve time resolution. A software framework has been developed to analyse the SAMPIC output data and extract timing information by using either a constant fraction discriminator or a fast cross-correlation algorithm. SAMPIC timing capabilities together with the software framework have been tested using pulses generated by a signal generator or by a silicon detector illuminated by a pulsed infrared laser. Under these ideal experimental conditions, the SAMPIC chip has proven to be capable of timing resolutions down to 4 ps with synthesized signals and 40 ps with silicon detector signals.

  12. LEARNING ONE-DIGIT DECIMAL NUMBERS BY MEASUREMENT AND GAME PREDICTING LENGTH

    Directory of Open Access Journals (Sweden)

    Puji Astuti

    2014-01-01

    Full Text Available This paper aims to describe how students develop understanding of one-digit decimals. To achieve the aim, Local Instruction Theory (LIT about the process of learning decimals and the means designed to support that learning are developed. Along with this idea, the framework of Realistic Mathematics Education (RME is proposed. Based on the aim, design research methodology is used. This paper discusses learning activities of three meetings from teaching experiment of the focus group students of the fourth grade elementary school in Surabaya: SDIT Al Ghilmani. The data indicated that the learning activities promoted the students’ understanding of one-digit decimal numbers.Keyword: measurement, decimal numbers, number line DOI: http://dx.doi.org/10.22342/jme.5.1.1447.35-46

  13. Measuring opto-thermal parameters of basalt fibers using digital holographic microscopy.

    Science.gov (United States)

    Yassien, Khaled M; Agour, Mostafa

    2017-02-01

    A method for studying the effect of temperature on the optical properties of basalt fiber is presented. It is based on recording a set of phase-shifted digital holograms for the sample under the test. The holograms are obtained utilizing a system based on Mach-Zehnder interferometer, where the fiber sample inserted in an immersion liquid is placed within a temperature controlled chamber. From the recorded digital holograms the optical path differences which are used to calculate the refractive indices are determined. The accuracy in the measurement of refractive indices is in the range of 4 × 10 -4 . The influence of temperature on the dispersion parameters, polarizability per unit volume and dielectric susceptibility are also obtained. Moreover, the values of dispersion and oscillation energies and Cauchy's constants are provided at different temperatures. © 2016 Wiley Periodicals, Inc.

  14. Method for Measuring the Information Content of Terrain from Digital Elevation Models

    Directory of Open Access Journals (Sweden)

    Lujin Hu

    2015-10-01

    Full Text Available As digital terrain models are indispensable for visualizing and modeling geographic processes, terrain information content is useful for terrain generalization and representation. For terrain generalization, if the terrain information is considered, the generalized terrain may be of higher fidelity. In other words, the richer the terrain information at the terrain surface, the smaller the degree of terrain simplification. Terrain information content is also important for evaluating the quality of the rendered terrain, e.g., the rendered web terrain tile service in Google Maps (Google Inc., Mountain View, CA, USA. However, a unified definition and measures for terrain information content have not been established. Therefore, in this paper, a definition and measures for terrain information content from Digital Elevation Model (DEM, i.e., a digital model or 3D representation of a terrain’s surface data are proposed and are based on the theory of map information content, remote sensing image information content and other geospatial information content. The information entropy was taken as the information measuring method for the terrain information content. Two experiments were carried out to verify the measurement methods of the terrain information content. One is the analysis of terrain information content in different geomorphic types, and the results showed that the more complex the geomorphic type, the richer the terrain information content. The other is the analysis of terrain information content with different resolutions, and the results showed that the finer the resolution, the richer the terrain information. Both experiments verified the reliability of the measurements of the terrain information content proposed in this paper.

  15. A Review of Surface Deformation and Strain Measurement Using Two-Dimensional Digital Image Correlation

    Directory of Open Access Journals (Sweden)

    Khoo Sze-Wei

    2016-09-01

    Full Text Available Among the full-field optical measurement methods, the Digital Image Correlation (DIC is one of the techniques which has been given particular attention. Technically, the DIC technique refers to a non-contact strain measurement method that mathematically compares the grey intensity changes of the images captured at two different states: before and after deformation. The measurement can be performed by numerically calculating the displacement of speckles which are deposited on the top of object’s surface. In this paper, the Two-Dimensional Digital Image Correlation (2D-DIC is presented and its fundamental concepts are discussed. Next, the development of the 2D-DIC algorithms in the past 33 years is reviewed systematically. The improvement of 2DDIC algorithms is presented with respect to two distinct aspects: their computation efficiency and measurement accuracy. Furthermore, analysis of the 2D-DIC accuracy is included, followed by a review of the DIC applications for two-dimensional measurements.

  16. Objective and Subjective Measures of Simultaneous vs Sequential Bilateral Cochlear Implants in Adults A Randomized Clinical Trial : A Randomized Clinical Trial

    NARCIS (Netherlands)

    Kraaijenga, Véronique J C; Ramakers, Geerte G J; Smulders, Yvette E; van Zon, Alice; Stegeman, Inge; Smit, Adriana L; Stokroos, Robert J; Hendrice, Nadia; Free, Rolien H; Maat, Bert; Frijns, Johan H M; Briaire, Jeroen J; Mylanus, E A M; Huinck, Wendy J; Van Zanten, Gijsbert A; Grolman, Wilko

    IMPORTANCE To date, no randomized clinical trial on the comparison between simultaneous and sequential bilateral cochlear implants (BiCIs) has been performed. OBJECTIVE To investigate the hearing capabilities and the self-reported benefits of simultaneous BiCIs compared with those of sequential

  17. An Analog-Digital Mixed Measurement Method of Inductive Proximity Sensor

    Directory of Open Access Journals (Sweden)

    Yi-Xin Guo

    2015-12-01

    Full Text Available Inductive proximity sensors (IPSs are widely used in position detection given their unique advantages. To address the problem of temperature drift, this paper presents an analog-digital mixed measurement method based on the two-dimensional look-up table. The inductance and resistance components can be separated by processing the measurement data, thus reducing temperature drift and generating quantitative outputs. This study establishes and implements a two-dimensional look-up table that reduces the online computational complexity through structural modeling and by conducting an IPS operating principle analysis. This table is effectively compressed by considering the distribution characteristics of the sample data, thus simplifying the processing circuit. Moreover, power consumption is reduced. A real-time, built-in self-test (BIST function is also designed and achieved by analyzing abnormal sample data. Experiment results show that the proposed method obtains the advantages of both analog and digital measurements, which are stable, reliable, and taken in real time, without the use of floating-point arithmetic and process-control-based components. The quantitative output of displacement measurement accelerates and stabilizes the system control and detection process. The method is particularly suitable for meeting the high-performance requirements of the aviation and aerospace fields.

  18. Accurate kinematic measurement at interfaces between dissimilar materials using conforming finite-element-based digital image correlation

    KAUST Repository

    Tao, Ran; Moussawi, Ali; Lubineau, Gilles; Pan, Bing

    2016-01-01

    Digital image correlation (DIC) is now an extensively applied full-field measurement technique with subpixel accuracy. A systematic drawback of this technique, however, is the smoothening of the kinematic field (e.g., displacement and strains

  19. Effective x-ray attenuation measurements with full field digital mammography

    International Nuclear Information System (INIS)

    Heine, John J.; Behera, Madhusmita

    2006-01-01

    This work shows that effective x-ray attenuation coefficients may be estimated by applying Beer's Law to phantom image data acquired with the General Electric Senographe 2000D full field digital mammography system. Theoretical developments are provided indicating that an approximate form of the Beer's relation holds for polychromatic x-ray beams. The theoretical values were compared with experimentally determined measured values, which were estimated at various detector locations. The measured effective attenuation coefficients are in agreement with those estimated with theoretical developments and numerical integration. The work shows that the measured quantities show little spatial variation. The main ideas are demonstrated with polymethylmethacrylate and breast tissue equivalent phantom imaging experiments. The work suggests that the effective attenuation coefficients may be used as known values for radiometric standardization applications that compensate for the image acquisition influences. The work indicates that it is possible to make quantitative attenuation coefficient measurements from a system designed for clinical purposes

  20. Measurement of proton-beam parameters by means of digital television diagnostic system

    International Nuclear Information System (INIS)

    Vazhenin, V.A.; Borovkov, S.D.; Evtikhiev, A.V.

    1992-01-01

    A method is described for measurement of the parameters of pulse-packet beams by means of a digital television diagnostic system. Results of tests of the system in measurement of the parameters of a proton beam with an energy of 1.35 GeV in the U-70 circular accelerator and results of measurements of the energy spectrum of the 30-MeV proton beam of the LU-30 linear accelerator are given. The possibility is shown of using the system to measure the integrated characteristics of an entire beam-pulse packet as well as the characteristics of individual pulses with a period of 60 msec. 6 refs., 4 figs., 1 tab

  1. Evaluating and measuring the value, use and impact of digital collections

    CERN Document Server

    Hughes, Lorna M

    2011-01-01

    Brings together a group of international experts to consider the following key issues: What is the role of digital resources in the research life cycle? Do the arts and humanities face a 'data deluge'? How are digital collections to be sustained over the long term? What is the role of digital collections in the 'digital economy'?

  2. Review: Michael Crandall & Karen E. Fisher (Eds) Digital Inclusion: Measuring the Impact of Information and Community Technology

    DEFF Research Database (Denmark)

    Pors, Niels Ole

    2010-01-01

    Review: Michael Crandall & Karen E. Fisher (Eds) Digital Inclusion: Measuring the Impact of Information and Community Technology. Medford. Information Today. ASIS&T Monographs, 2009. 185 pages. $ 59.50. ISBN 978-1-57387-373-4......Review: Michael Crandall & Karen E. Fisher (Eds) Digital Inclusion: Measuring the Impact of Information and Community Technology. Medford. Information Today. ASIS&T Monographs, 2009. 185 pages. $ 59.50. ISBN 978-1-57387-373-4...

  3. Simultaneous measurement of refractive index and thickness distributions using low-coherence digital holography and vertical scanning

    International Nuclear Information System (INIS)

    Watanabe, Kaho; Ohshima, Masashi; Nomura, Takanori

    2014-01-01

    The simultaneous measurement method of a refractive index distribution and a thickness distribution using low-coherence digital holography with a vertical scanning is proposed. The proposed method consists of a combination of digital holography and low-coherence interferometry. The introduction of a datum plane enables the measurement of both a refractive index distribution and a thickness distribution. By the optical experiment, the potential of the proposed method is confirmed. (paper)

  4. A Cost-Effective Transparency-Based Digital Imaging for Efficient and Accurate Wound Area Measurement

    Science.gov (United States)

    Li, Pei-Nan; Li, Hong; Wu, Mo-Li; Wang, Shou-Yu; Kong, Qing-You; Zhang, Zhen; Sun, Yuan; Liu, Jia; Lv, De-Cheng

    2012-01-01

    Wound measurement is an objective and direct way to trace the course of wound healing and to evaluate therapeutic efficacy. Nevertheless, the accuracy and efficiency of the current measurement methods need to be improved. Taking the advantages of reliability of transparency tracing and the accuracy of computer-aided digital imaging, a transparency-based digital imaging approach is established, by which data from 340 wound tracing were collected from 6 experimental groups (8 rats/group) at 8 experimental time points (Day 1, 3, 5, 7, 10, 12, 14 and 16) and orderly archived onto a transparency model sheet. This sheet was scanned and its image was saved in JPG form. Since a set of standard area units from 1 mm2 to 1 cm2 was integrated into the sheet, the tracing areas in JPG image were measured directly, using the “Magnetic lasso tool” in Adobe Photoshop program. The pixel values/PVs of individual outlined regions were obtained and recorded in an average speed of 27 second/region. All PV data were saved in an excel form and their corresponding areas were calculated simultaneously by the formula of Y (PV of the outlined region)/X (PV of standard area unit) × Z (area of standard unit). It took a researcher less than 3 hours to finish area calculation of 340 regions. In contrast, over 3 hours were expended by three skillful researchers to accomplish the above work with traditional transparency-based method. Moreover, unlike the results obtained traditionally, little variation was found among the data calculated by different persons and the standard area units in different sizes and shapes. Given its accurate, reproductive and efficient properties, this transparency-based digital imaging approach would be of significant values in basic wound healing research and clinical practice. PMID:22666449

  5. Measuring relais as an alternative to digital protective systems; Messende Relais als Alternative zu digitalen Schutzsystemen

    Energy Technology Data Exchange (ETDEWEB)

    Wolf, Rainer [Ingenieurgemeinschaft Energieversorgung GbR, Meiningen (Germany)

    2011-07-15

    In order to keep the occasionally severe consequences of electrical faults in switchgear, cables and transformers as low as possible, to reduce the risk to persons and to continue the operation of the not disturbed grid, measuring relays provide for fast and selective fault detection and fault shutdown. In general, it is thought at digital protection systems which are designed for example as a differential protection, distance protection and overcurrent protection. Some applications, however, get along with a lower level of equipment technology, and can be realized more cost-effectively.

  6. Staged bilateral carotid endarterectomy

    DEFF Research Database (Denmark)

    Schroeder, T; Sillesen, H; Engell, Hans Christian

    1986-01-01

    In a series of 56 staged bilateral carotid endarterectomies, new neurologic symptoms developed in 5% and 20% following the first and second procedure, respectively. All complications were transient or minor. The incidence of postendarterectomy hypertension was significantly higher following...... the second procedure, when operations were staged less than 3 weeks apart. A correlation between these hypertensive episodes and the occurrence of new neurologic symptoms could not be shown. However, as this correlation has been proved in several other reports, bilateral carotid endarterectomy is advised...... to be staged at least 3 weeks apart. In addition, a conservative attitude towards contralateral asymptomatic lesions is proposed....

  7. Diagnostic accuracy and measurement sensitivity of digital models for orthodontic purposes: A systematic review.

    Science.gov (United States)

    Rossini, Gabriele; Parrini, Simone; Castroflorio, Tommaso; Deregibus, Andrea; Debernardi, Cesare L

    2016-02-01

    Our objective was to assess the accuracy, validity, and reliability of measurements obtained from virtual dental study models compared with those obtained from plaster models. PubMed, PubMed Central, National Library of Medicine Medline, Embase, Cochrane Central Register of Controlled Clinical trials, Web of Knowledge, Scopus, Google Scholar, and LILACs were searched from January 2000 to November 2014. A grading system described by the Swedish Council on Technology Assessment in Health Care and the Cochrane tool for risk of bias assessment were used to rate the methodologic quality of the articles. Thirty-five relevant articles were selected. The methodologic quality was high. No significant differences were observed for most of the studies in all the measured parameters, with the exception of the American Board of Orthodontics Objective Grading System. Digital models are as reliable as traditional plaster models, with high accuracy, reliability, and reproducibility. Landmark identification, rather than the measuring device or the software, appears to be the greatest limitation. Furthermore, with their advantages in terms of cost, time, and space required, digital models could be considered the new gold standard in current practice. Copyright © 2016 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  8. Measurement of the presampled two-dimensional modulation transfer function of digital imaging systems

    International Nuclear Information System (INIS)

    Fetterly, Kenneth A.; Hangiandreou, Nicholas J.; Schueler, Beth A.; Ritenour, E. Russell

    2002-01-01

    The purpose of this work was to develop methods to measure the presampled two-dimensional modulation transfer function (2D MTF) of digital imaging systems. A custom x-ray 'point source' phantom was created by machining 256 holes with diameter 0.107 mm through a 0.5-mm-thick copper plate. The phantom was imaged several times, resulting in many images of individual x-ray 'spots'. The center of each spot (with respect to the pixel matrix) was determined to subpixel accuracy by fitting each spot to a 2D Gaussian function. The subpixel spot center locations were used to create a 5x oversampled system point spread function (PSF), which characterizes the optical and electrical properties of the system and is independent of the pixel sampling of the original image. The modulus of the Fourier transform of the PSF was calculated. Next, the Fourier function was normalized to the zero frequency value. Finally, the Fourier transform function was divided by the first-order Bessel function that defined the frequency content of the holes, resulting in the presampled 2D MTF. The presampled 2D MTF of a 0.1 mm pixel pitch computed radiography system and 0.2 mm pixel pitch flat panel digital imaging system that utilized a cesium iodide scintillator was measured. Comparison of the axial components of the 2D MTF to one-dimensional MTF measurements acquired using an edge device method demonstrated that the two methods produced consistent results

  9. Measurement of definite integral of sinusoidal signal absolute value third power using digital stochastic method

    Directory of Open Access Journals (Sweden)

    Beljić Željko

    2017-01-01

    Full Text Available In this paper a special case of digital stochastic measurement of the third power of definite integral of sinusoidal signal’s absolute value, using 2-bit AD converters is presented. This case of digital stochastic method had emerged from the need to measure power and energy of the wind. Power and energy are proportional to the third power of wind speed. Anemometer output signal is sinusoidal. Therefore an integral of the third power of sinusoidal signal is zero. Two approaches are proposed for the third power calculation of the wind speed signal. One approach is to use absolute value of sinusoidal signal (before AD conversion for which there is no need of multiplier hardware change. The second approach requires small multiplier hardware change, but input signal remains unchanged. For the second approach proposed minimal hardware change was made to calculate absolute value of the result after AD conversion. Simulations have confirmed theoretical analysis. Expected precision of wind energy measurement of proposed device is better than 0,00051% of full scale. [Project of the Serbian Ministry of Education, Science and Technological Development, Grant no. TR32019

  10. Development of Gravity Acceleration Measurement Using Simple Harmonic Motion Pendulum Method Based on Digital Technology and Photogate Sensor

    Science.gov (United States)

    Yulkifli; Afandi, Zurian; Yohandri

    2018-04-01

    Development of gravitation acceleration measurement using simple harmonic motion pendulum method, digital technology and photogate sensor has been done. Digital technology is more practical and optimizes the time of experimentation. The pendulum method is a method of calculating the acceleration of gravity using a solid ball that connected to a rope attached to a stative pole. The pendulum is swung at a small angle resulted a simple harmonic motion. The measurement system consists of a power supply, Photogate sensors, Arduino pro mini and seven segments. The Arduino pro mini receives digital data from the photogate sensor and processes the digital data into the timing data of the pendulum oscillation. The calculation result of the pendulum oscillation time is displayed on seven segments. Based on measured data, the accuracy and precision of the experiment system are 98.76% and 99.81%, respectively. Based on experiment data, the system can be operated in physics experiment especially in determination of the gravity acceleration.

  11. Body Mass Index (BMI) in women booking for antenatal care: comparison between selfreported and digital measurements.

    LENUS (Irish Health Repository)

    Fattah, Chro

    2012-02-01

    OBJECTIVE: We set out to compare measurement of Body Mass Index (BMI) with selfreporting in women early in pregnancy. STUDY DESIGN: We studied 100 women booking for antenatal care in the first trimester with a normal ongoing pregnancy. Selfreported maternal weight and height were recorded and the Body Mass Index was calculated. Afterwards maternal weight and height were digitally measured and actual BMI was calculated. RESULTS: If selfreporting is used for BMI classification, we found that 22% of women were classified incorrectly when BMI was measured. 12% of the women who were classified as having a normal selfreported BMI were overweight and 5% classified as overweight were obese. Similar findings have been reported outside pregnancy. CONCLUSIONS: These findings have implications for clinical practice, and for research studies exploring the relationship between maternal adiposity and pregnancy complications.

  12. International Interlaboratory Digital PCR Study Demonstrating High Reproducibility for the Measurement of a Rare Sequence Variant.

    Science.gov (United States)

    Whale, Alexandra S; Devonshire, Alison S; Karlin-Neumann, George; Regan, Jack; Javier, Leanne; Cowen, Simon; Fernandez-Gonzalez, Ana; Jones, Gerwyn M; Redshaw, Nicholas; Beck, Julia; Berger, Andreas W; Combaret, Valérie; Dahl Kjersgaard, Nina; Davis, Lisa; Fina, Frederic; Forshew, Tim; Fredslund Andersen, Rikke; Galbiati, Silvia; González Hernández, Álvaro; Haynes, Charles A; Janku, Filip; Lacave, Roger; Lee, Justin; Mistry, Vilas; Pender, Alexandra; Pradines, Anne; Proudhon, Charlotte; Saal, Lao H; Stieglitz, Elliot; Ulrich, Bryan; Foy, Carole A; Parkes, Helen; Tzonev, Svilen; Huggett, Jim F

    2017-02-07

    This study tested the claim that digital PCR (dPCR) can offer highly reproducible quantitative measurements in disparate laboratories. Twenty-one laboratories measured four blinded samples containing different quantities of a KRAS fragment encoding G12D, an important genetic marker for guiding therapy of certain cancers. This marker is challenging to quantify reproducibly using quantitative PCR (qPCR) or next generation sequencing (NGS) due to the presence of competing wild type sequences and the need for calibration. Using dPCR, 18 laboratories were able to quantify the G12D marker within 12% of each other in all samples. Three laboratories appeared to measure consistently outlying results; however, proper application of a follow-up analysis recommendation rectified their data. Our findings show that dPCR has demonstrable reproducibility across a large number of laboratories without calibration. This could enable the reproducible application of molecular stratification to guide therapy and, potentially, for molecular diagnostics.

  13. Residual stresses measurement by using ring-core method and 3D digital image correlation technique

    International Nuclear Information System (INIS)

    Hu, Zhenxing; Xie, Huimin; Zhu, Jianguo; Wang, Huaixi; Lu, Jian

    2013-01-01

    Ring-core method/three-dimensional digital image correlation (3D DIC) residual stresses measurement is proposed. Ring-core cutting is a mechanical stress relief method, and combining with 3D DIC system the deformation of the specimen surface can be measured. An optimization iteration method is proposed to obtain the residual stress and rigid-body motion. The method has the ability to cut an annular trench at a different location out of the field of view. A compression test is carried out to demonstrate how residual stress is determined by using 3D DIC system and outfield measurement. The results determined by the approach are in good agreement with the theoretical value. Ring-core/3D DIC has shown its robustness to determine residual stress and can be extended to application in the engineering field. (paper)

  14. Development of a precise long-time digital integrator for magnetic measurements in a tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Kurihara, Kenichi; Kawamata, Youichi [Japan Atomic Energy Research Inst., Naka, Ibaraki (Japan). Naka Fusion Research Establishment

    1997-10-01

    Long-time D-T burning operation in a tokamak requires that a magnetic sensor must work in an environment of 14-MeV intense neutron field, and that the measurement system must output precise magnetic field values. A method of time-integration of voltage produced in a simple pick-up coil seems to have preferable features of good time response, easy maintenance, and resistance to neutron irradiation. However, an inevitably-produced signal drift makes it difficult to apply the method to the long-time integral operation. To solve this problem, we have developed a new digital integrator (a voltage-to-frequency converter and an up-down counter) with testing the trial boards in the JT-60 magnetic measurements. This reports all of the problems and their measures through the development steps in details, and shows how to apply this method to the ITER operation. (author)

  15. Digital PIV Measurements in the Diffuser of a High Speed Centrifugal Compressor

    Science.gov (United States)

    Wernet, Mark P.

    1998-01-01

    Particle Imaging Velocimetry (PIV) is a powerful measurement technique which can be used as an alternative or complementary approach to Laser Doppler Velocimetry (LDV) in a wide range of research applications. PIV data are measured simultaneously at multiple points in space, which enables the investigation of the non-stationary spatial structures typically encountered in turbomachinery. Obtaining ample optical access, sufficiently high seed particle concentrations and accurate synchronization of image acquisition relative to impeller position are the most formidable tasks in the successful implementation of PIV in turbomachinery. Preliminary results from the successful application of the standard 2-D digital PIV technique in the diffuser of a high speed centrifugal compressor are presented. Instantaneous flow. measurements were also obtained during compressor surge.

  16. Uncertainty characterization of particle depth measurement using digital in-line holography and the hybrid method.

    Science.gov (United States)

    Gao, Jian; Guildenbecher, Daniel R; Reu, Phillip L; Chen, Jun

    2013-11-04

    In the detection of particles using digital in-line holography, measurement accuracy is substantially influenced by the hologram processing method. In particular, a number of methods have been proposed to determine the out-of-plane particle depth (z location). However, due to the lack of consistent uncertainty characterization, it has been unclear which method is best suited to a given measurement problem. In this work, depth determination accuracies of seven particle detection methods, including a recently proposed hybrid method, are systematically investigated in terms of relative depth measurement errors and uncertainties. Both synthetic and experimental holograms of particle fields are considered at conditions relevant to particle sizing and tracking. While all methods display a range of particle conditions where they are most accurate, in general the hybrid method is shown to be the most robust with depth uncertainty less than twice the particle diameter over a wide range of particle field conditions.

  17. Bilateral meandering pulmonary veins

    Energy Technology Data Exchange (ETDEWEB)

    Thupili, Chakradhar R.; Udayasankar, Unni [Pediatric Imaging, Imaging Institute Cleveland Clinic, Cleveland, OH (United States); Renapurkar, Rahul [Imaging Institute Cleveland Clinic, Thoracic Imaging, L10, Cleveland, OH (United States)

    2015-06-15

    Meandering pulmonary veins is a rare clinical entity that can be mistaken for more complex congenital syndromes such as hypogenetic lung syndrome. We report imaging findings in a rare incidentally detected case of bilateral meandering pulmonary veins. We briefly discuss the role of imaging in diagnosing this condition, with particular emphasis on contrast-enhanced CT. (orig.)

  18. Bilateral Periventricular Nodular Heterotopia

    OpenAIRE

    J Gordon Millichap

    1998-01-01

    Two unrelated boys, ages 8 and 5 years, with a syndrome of bilateral periventricular nodular heterotopia (BPNH), regional cortical dysplasia, mild mental retardation, and frontonasal malformation (FNM) are reported from the Instituto di Neuropsychiatria Infantile, University of Pisa, Italy, and the Institute of Human Genetics, University of Minnesota Medical School, Minneapolis, MN.

  19. Homogeneous bilateral block shifts

    Indian Academy of Sciences (India)

    Douglas class were classified in [3]; they are unilateral block shifts of arbitrary block size (i.e. dim H(n) can be anything). However, no examples of irreducible homogeneous bilateral block shifts of block size larger than 1 were known until now.

  20. Synchronous, bilateral tonsillar carcinomas

    DEFF Research Database (Denmark)

    Nami Saber, Camelia; Grønhøj, Christian; Jensen, David Hebbelstrup

    2017-01-01

    INTRODUCTION: The incidence of oropharyngeal squamous cell carcinoma (OPSCC) is increasing, but data on the incidence of synchronous, bilateral tonsillar squamous cell carcinomas (BiTSCCs) is sparse. In this study, we report the incidence and tumour characteristics of BiTSCCs in a population-base...

  1. Bilateral breast carcinoma

    International Nuclear Information System (INIS)

    Kim, Eung Jo; Oh, Ki Keun

    1990-01-01

    We evaluate 311 breast cancer patients admitted to Yong Dong Severance Hospital Between October 1st 1985 and July 31th 1989, and were able to obtain the following conclusions. 1) There were 14(4.5%) bilateral breast cancers among the 311 confirmed breast cancers. 2) Among the bilateral breast cancers, 5(31%) were synchronous and 9(69%) metachronous. 3) Average interval between the first and the second breast cancer in metachronous cancers was 3.8 year(1-15 years). 4) Bilateral breast cancer was most prevalent in the fifth decade (6/14) with the mean age of 47 years. 5) Film mammogram and sonomammogram showed findings of typical breast malignancies. There was no additional specific findings for each cancer in bilateral breast cancers which was different from unilateral cancers. Therefor, in the patients with unilateral breast cancer, possibility of the second lesion in the contralateral side must be considered and a close follow up observation should be done for at least 3 years

  2. DIMOND II: Measures for optimising radiological information content and dose in digital imaging

    International Nuclear Information System (INIS)

    Dowling, A.; Malone, J.; Marsh, D.

    2001-01-01

    The European Commission concerted action on 'Digital Imaging: Measures for Optimising Radiological Information Content and Dose', DIMOND II, was conducted by 12 European partners over the period January 1997 to June 1999. The objective of the concerted action was to initiate a project in the area of digital medical imaging where practice was evolving without structured research in radiation protection, optimisation or justification. The main issues addressed were patient and staff dosimetry, image quality, quality criteria and technical issues. The scope included computed radiography (CR), image intensifier radiography and fluoroscopy, cardiology and interventional procedures. The concerted action was based on the consolidation of work conducted in the partner's institutions together with elective new work. Protocols and approaches to dosimetry, radiological information content/image quality measurement and quality criteria were established and presented at an international workshop held in Dublin in June 1999. Details of the work conducted during the DIMOND II concerted action and a summary of the main findings and conclusions are presented in this contribution. (author)

  3. Numerical investigation of the effect of particle concentration on particle measurement by digital holography

    Science.gov (United States)

    Zhao, Huafeng; Zhou, Binwu; Wu, Xuecheng; Wu, Yingchun; Gao, Xiang; Gréhan, Gérard; Cen, Kefa

    2014-04-01

    Digital holography plays a key role in particle field measurement, and appears to be a strong contender as the next-generation technology for diagnostics of 3D particle field. However, various recording parameters, such as the recording distance, the particle size, the wavelength, the size of the CCD chip, the pixel size and the particle concentration, will affect the results of the reconstruction, and may even determine the success or failure of a measurement. This paper presents a numerical investigation on the effect of particle concentration, the volume depth to evaluate the capability of digital holographic microscopy. Standard particles holograms with all known recording parameters are numerically generated by using a common procedure based on Lorenz-Mie scattering theory. Reconstruction of those holograms are then performed by a wavelet-transform based method. Results show that the reconstruction efficiency decreases quickly until particle concentration reaches 50×104 (mm-3), and decreases linearly with the increase of particle concentration from 50 × 104 (mm-3) to 860 × 104 (mm-3) in the same volume. The first half of the line waves larger than the second half. It also indicates that the increase of concentration leads the rise in average diameter error and z position error of particles. Besides, the volume depth also plays a key role in reconstruction.

  4. MEASURING AIR AND TERRESTRIAL TRANSPORT COMPANY REPUTATION: TOURISM INTANGIBLES EXPRESSED IN THE DIGITAL ENVIRONMENT

    Directory of Open Access Journals (Sweden)

    Célia M.Q. Ramos

    2017-12-01

    Full Text Available The reputation of companies within the transport industry is influenced by competitive dynamics within the sector: low-cost flights, the attractiveness of destinations, online user-generated content about users’ experiences, and more. At the same time, social media provides a means for companies to manage issues of tourism intangibles. Thus, it is relevant to analyse transport reputation in the digital environment, taking into consideration the resources for managing these intangibles. This paper presents a method for measuring transport reputation based on an analysis of tourism consumers’ digital opinions and passengers’ comments about their experiences with these firms. The use of social media, such as TripAdvisor and Facebook, conjugated with business intelligence tools and complemented by data mining techniques, can contribute to the development of metrics that consider intangibles like emotions and experiences, with the aim of measuring, analysing, and visualizing the complex relationships between these intangibles and transport companies’ reputations. The results present the impacts of these intangibles through clusters and positioning maps focusing on these issues. This investigation contributes to our knowledge about airlines and terrestrial transport companies that seek to differentiate their positioning in tourism markets through their reputations.

  5. Measurements of oil spill spreading in a wave tank using digital image processing

    International Nuclear Information System (INIS)

    Flores, H.; Saavedra, I.; Andreatta, A.; Llona, G.

    1998-01-01

    In this work, an experimental study of spreading of crude oil is carried out in a wave tank. The tests are performed by spilling different volumes and types of crude oil on the water surface. An experimental measurement technique was developed based on digital processing of video images. The acquisition and processing of such images is carried out by using a video camera and inexpensive microcomputer hardware and software. Processing is carried out by first performing a digital image filter, then edge detection is performed on the filtered image data. The final result is a file that contains the coordinates of a polygon that encloses the observed slick for each time step. Different types of filters are actually used in order to adequately separate the color intensifies corresponding to each of the elements in the image. Postprocessing of the vectorized images provides accurate measurements of the slick edge, thus obtaining a complete geometric representation, which is significantly different from simplified considerations of radially symmetric spreading. The spreading of the oil slick was recorded for each of the tests. Results of the experimental study are presented for each spreading regime, and analyzed in terms of the wave parameters such as period and wave height. (author)

  6. Automatic centroid detection and surface measurement with a digital Shack–Hartmann wavefront sensor

    International Nuclear Information System (INIS)

    Yin, Xiaoming; Zhao, Liping; Li, Xiang; Fang, Zhongping

    2010-01-01

    With the breakthrough of manufacturing technologies, the measurement of surface profiles is becoming a big issue. A Shack–Hartmann wavefront sensor (SHWS) provides a promising technology for non-contact surface measurement with a number of advantages over interferometry. The SHWS splits the incident wavefront into many subsections and transfers the distorted wavefront detection into the centroid measurement. So the accuracy of the centroid measurement determines the accuracy of the SHWS. In this paper, we have presented a new centroid measurement algorithm based on an adaptive thresholding and dynamic windowing method by utilizing image-processing techniques. Based on this centroid detection method, we have developed a digital SHWS system which can automatically detect centroids of focal spots, reconstruct the wavefront and measure the 3D profile of the surface. The system has been tested with various simulated and real surfaces such as flat surfaces, spherical and aspherical surfaces as well as deformable surfaces. The experimental results demonstrate that the system has good accuracy, repeatability and immunity to optical misalignment. The system is also suitable for on-line applications of surface measurement

  7. Miniaturized multiwavelength digital holography sensor for extensive in-machine tool measurement

    Science.gov (United States)

    Seyler, Tobias; Fratz, Markus; Beckmann, Tobias; Bertz, Alexander; Carl, Daniel

    2017-06-01

    In this paper we present a miniaturized digital holographic sensor (HoloCut) for operation inside a machine tool. With state-of-the-art 3D measurement systems, short-range structures such as tool marks cannot be resolved inside a machine tool chamber. Up to now, measurements had to be conducted outside the machine tool and thus processing data are generated offline. The sensor presented here uses digital multiwavelength holography to get 3D-shape-information of the machined sample. By using three wavelengths, we get a large artificial wavelength with a large unambiguous measurement range of 0.5mm and achieve micron repeatability even in the presence of laser speckles on rough surfaces. In addition, a digital refocusing algorithm based on phase noise is implemented to extend the measurement range beyond the limits of the artificial wavelength and geometrical depth-of-focus. With complex wave field propagation, the focus plane can be shifted after the camera images have been taken and a sharp image with extended depth of focus is constructed consequently. With 20mm x 20mm field of view the sensor enables measurement of both macro- and micro-structure (such as tool marks) with an axial resolution of 1 µm, lateral resolution of 7 µm and consequently allows processing data to be generated online which in turn qualifies it as a machine tool control. To make HoloCut compact enough for operation inside a machining center, the beams are arranged in two planes: The beams are split into reference beam and object beam in the bottom plane and combined onto the camera in the top plane later on. Using a mechanical standard interface according to DIN 69893 and having a very compact size of 235mm x 140mm x 215mm (WxHxD) and a weight of 7.5 kg, HoloCut can be easily integrated into different machine tools and extends no more in height than a typical processing tool.

  8. Digital Pills to Measure Opioid Ingestion Patterns in Emergency Department Patients With Acute Fracture Pain: A Pilot Study.

    Science.gov (United States)

    Chai, Peter R; Carreiro, Stephanie; Innes, Brendan J; Rosen, Rochelle K; O'Cleirigh, Conall; Mayer, Kenneth H; Boyer, Edward W

    2017-01-13

    Nonadherence to prescribed regimens for opioid analgesic agents contributes to increasing opioid abuse and overdose death. Opioids are frequently prescribed on an as-needed basis, placing the responsibility to determine opioid dose and frequency with the patient. There is wide variability in physician prescribing patterns because of the lack of data describing how patients actually use as-needed opioid analgesics. Digital pill systems have a radiofrequency emitter that directly measures medication ingestion events, and they provide an opportunity to discover the dose, timing, and duration of opioid therapy. The purpose of this study was to determine the feasibility of a novel digital pill system to measure as-needed opioid ingestion patterns in patients discharged from the emergency department (ED) after an acute bony fracture. We used a digital pill with individuals who presented to a teaching hospital ED with an acute extremity fracture. The digital pill consisted of a digital radiofrequency emitter within a standard gelatin capsule that encapsulated an oxycodone tablet. When ingested, the gastric chloride ion gradient activated the digital pill, transmitting a radiofrequency signal that was received by a hip-worn receiver, which then transmitted the ingestion data to a cloud-based server. After a brief, hands-on training session in the ED, study participants were discharged home and used the digital pill system to ingest oxycodone prescribed as needed for pain for one week. We conducted pill counts to verify digital pill data and open-ended interviews with participants at their follow-up appointment with orthopedics or at one week after enrollment in the study to determine the knowledge, attitudes, beliefs, and practices regarding digital pills. We analyzed open-ended interviews using applied thematic analysis. We recruited 10 study participants and recorded 96 ingestion events (87.3%, 96/110 accuracy). Study participants reported being able to operate all

  9. Measurement of clavicular length and shortening after a midshaft clavicular fracture: Spatial digitization versus planar roentgen photogrammetry.

    Science.gov (United States)

    Stegeman, Sylvia A; de Witte, Pieter Bas; Boonstra, Sjoerd; de Groot, Jurriaan H; Nagels, Jochem; Krijnen, Pieta; Schipper, Inger B

    2016-08-01

    Clavicular shortening after fracture is deemed prognostic for clinical outcome and is therefore generally assessed on radiographs. It is used for clinical decision making regarding operative or non-operative treatment in the first 2weeks after trauma, although the reliability and accuracy of the measurements are unclear. This study aimed to assess the reliability of roentgen photogrammetry (2D) of clavicular length and shortening, and to compare these with 3D-spatial digitization measurements, obtained with an electromagnetic recording system (Flock of Birds). Thirty-two participants with a consolidated non-operatively treated two or multi-fragmented dislocated midshaft clavicular fracture were analysed. Two observers measured clavicular lengths and absolute and proportional clavicular shortening on radiographs taken before and after fracture consolidation. The clavicular lengths were also measured with spatial digitization. Inter-observer agreement on the radiographic measurements was assessed using the Intraclass Correlation Coefficient (ICC). Agreement between the radiographic and spatial digitization measurements was assessed using a Bland-Altman plot. The inter-observer agreement on clavicular length, and absolute and proportional shortening on trauma radiographs was almost perfect (ICC>0.90), but moderate for absolute shortening after consolidation (ICC=0.45). The Bland-Altman plot compared measurements of length on AP panorama radiographs with spatial digitization and showed that planar roentgen photogrammetry resulted in up to 37mm longer and 34mm shorter measurements than spatial digitization. Measurements of clavicular length on radiographs are highly reliable between observers, but may not reflect the actual length and shortening of the clavicle when compared to length measurements with spatial digitization. We recommend to use proportional shortening when measuring clavicular length or shortening on radiographs for clinical decision making. Copyright

  10. Phasor Measurement Unit and Phasor Data Concentrator test with Real Time Digital Simulator

    DEFF Research Database (Denmark)

    Diakos, Konstantinos; Wu, Qiuwei; Nielsen, Arne Hejde

    2014-01-01

    that is able to derive and communicate synchrophasor measurements of different parts of the power network and the development of tests, according to IEEE standards, that evaluate the performance of PMUs and PDCs. The tests are created by using a Real Time Digital Simulation (RTDS) system. The results obtained......The main focus of the electrical engineers nowadays, is to develop a smart grid that is able to monitor, evaluate and control the power system operation. The integration of Intelligent Electronic Devices (IED s) to the power network, is a strong indication of the inclination to lead the power...... network to a more reliable, secure and economic operation. The implementation of these devices though, demands the warranty of a secure operation and high-accuracy performance. This paper describes the procedure of establishing a PMU (Phasor Measurement Unit)–PDC (Phasor Data Concentrator) platform...

  11. Measuring Down: Evaluating Digital Storytelling as a Process for Narrative Health Promotion.

    Science.gov (United States)

    Gubrium, Aline C; Fiddian-Green, Alice; Lowe, Sarah; DiFulvio, Gloria; Del Toro-Mejías, Lizbeth

    2016-05-15

    Digital storytelling (DST) engages participants in a group-based process to create and share narrative accounts of life events. We present key evaluation findings of a 2-year, mixed-methods study that focused on effects of participating in the DST process on young Puerto Rican Latina's self-esteem, social support, empowerment, and sexual attitudes and behaviors. Quantitative results did not show significant changes in the expected outcomes. However, in our qualitative findings we identified several ways in which the DST made positive, health-bearing effects. We argue for the importance of "measuring down" to reflect the locally grounded, felt experiences of participants who engage in the process, as current quantitative scales do not "measure up" to accurately capture these effects. We end by suggesting the need to develop mixed-methods, culturally relevant, and sensitive evaluation tools that prioritize process effects as they inform intervention and health promotion. © The Author(s) 2016.

  12. Sound quality measures for speech in noise through a commercial hearing aid implementing digital noise reduction.

    Science.gov (United States)

    Ricketts, Todd A; Hornsby, Benjamin W Y

    2005-05-01

    This brief report discusses the affect of digital noise reduction (DNR) processing on aided speech recognition and sound quality measures in 14 adults fitted with a commercial hearing aid. Measures of speech recognition and sound quality were obtained in two different speech-in-noise conditions (71 dBA speech, +6 dB SNR and 75 dBA speech, +1 dB SNR). The results revealed that the presence or absence of DNR processing did not impact speech recognition in noise (either positively or negatively). Paired comparisons of sound quality for the same speech in noise signals, however, revealed a strong preference for DNR processing. These data suggest that at least one implementation of DNR processing is capable of providing improved sound quality, for speech in noise, in the absence of improved speech recognition.

  13. Measurement methods updating for tandem-generator EGP-10K with using of digital technology

    Directory of Open Access Journals (Sweden)

    I. P. Dryapachenko

    2012-06-01

    Full Text Available During the last 10 years a number of fundamental and applied research at the electrostatic charge-exchange accelerator EGP-10K INR NAS with the proton and deuteron beams were performed. Currently, the program of optimization of the accelerator parameters, especially – the energy and intensity of the beam has being implemented. At the same time the possibilities of the transport and use of the accelerator beam through the creation of additional sections of beam tube and reaction chambers, as well as the possibilities of the measurements and data processing particularly, in the reconstructed measuring center of the previous single-stage accelerator EG-5, were improved. This paper presents the results of modernization of infrastructure of the experimental studies with the beams of the accelerator EGP-10K using the latest equipment and modern digital technique for beam diagnostics, registration of the reaction products and visualization of the obtained data.

  14. Measurement of Local Deformations in Steel Monostrands Using Digital Image Correlation

    DEFF Research Database (Denmark)

    Winkler, Jan; Fischer, Gregor; Georgakis, Christos T.

    2014-01-01

    The local deformation mechanisms in steel monostrands have a significant influence on their fatigue life and failure mode. However, the observation and quantification of deformations in monostrands experiencing axial and transverse deformations is challenging because of their complex geometry......, difficulties with the placement of strain gauges in the vicinity of the anchorage, and, most importantly, the relatively small magnitude of deformation occurring in the monostrand. This paper focuses on the measurement of localized deformations in high-strength steel monostrands using the digital image...... correlation (DIC) technique. The presented technique enables the measurement of individual wire strains along the length of the monostrand and also provides quantitative information on the relative movement between individual wires, leading to a more in-depth understanding of the underlying fatigue mechanisms...

  15. Evaluation and analytical validation of a handheld digital refractometer for urine specific gravity measurement

    Directory of Open Access Journals (Sweden)

    Sara P. Wyness

    2016-08-01

    Full Text Available Objectives: Refractometers are commonly used to determine urine specific gravity (SG in the assessment of hydration status and urine specimen validity testing. Few comprehensive performance evaluations are available demonstrating refractometer capability from a clinical laboratory perspective. The objective of this study was therefore to conduct an analytical validation of a handheld digital refractometer used for human urine SG testing. Design and methods: A MISCO Palm Abbe™ refractometer was used for all experiments, including device familiarization, carryover, precision, accuracy, linearity, analytical sensitivity, evaluation of potential substances which contribute to SG (i.e. “interference”, and reference interval evaluation. A manual refractometer, urine osmometer, and a solute score (sum of urine chloride, creatinine, glucose, potassium, sodium, total protein, and urea nitrogen; all in mg/dL were used as comparative methods for accuracy assessment. Results: Significant carryover was not observed. A wash step was still included as good laboratory practice. Low imprecision (%CV, <0.01 was demonstrated using low and high QC material. Accuracy studies showed strong correlation to manual refractometry. Linear correlation was also demonstrated between SG, osmolality, and solute score. Linearity of Palm Abbe performance was verified with observed error of ≤0.1%. Increases in SG were observed with increasing concentrations of albumin, creatinine, glucose, hemoglobin, sodium chloride, and urea. Transference of a previously published urine SG reference interval of 1.0020–1.0300 was validated. Conclusions: The Palm Abbe digital refractometer was a fast, simple, and accurate way to measure urine SG. Analytical validity was confirmed by the present experiments. Keywords: Specific gravity, Osmolality, Digital refractometry, Hydration, Sports medicine, Urine drug testing, Urine adulteration

  16. Nanoscale displacement measurement by a digital nano-moire method with wavelet transformation

    International Nuclear Information System (INIS)

    Liu, C-M; Chen, L-W; Wang, C-C

    2006-01-01

    A digital nano-moire method with wavelet transformation is explored to measure nanoscale in-plane displacement fields. By applying e-beam lithography, a periodic PMMA nanostructure array is fabricated directly on the specimen and used as the specimen grating. Moire patterns are generated by overlapping the images of the PMMA specimen grating obtained from AFM scanning and the virtual reference grating produced by a digital image generating process. Then, the overlapped images are filtered by the 2D wavelet transformation (WT) to capture the target moire patterns. Existing methods, by overlapping the monitor-generated scanning lines with the image of the specimen grating, cause a mismatch problem. Previously, the carrier moire method was explored with the aim of curing the mismatch problem. Unfortunately, the carrier moire method, in addition to suffering from increased complexity of mathematical calculations, is incapable of directly obtaining the displacement field. Thus, the mismatch problem will result in inconveniences and restrictions in the practical application. Instead of using monitor-generated scanning lines, the proposed method applies the virtual reference grating, and thus puts the mismatch problem to rest. Nevertheless, the resultant moire image suffers from low contrast which, if left untreated, might distort the measurement result. Therefore, the WT, known for its sharpened abilities of characteristic and edge detection, is used to capture the target moire patterns and improve the measurement accuracy. The proposed method has been carried out in the laboratory. Experimental results have shown that the proposed method is convenient and efficient for nanoscale displacement measurement

  17. Quantitative blood flow measurements in the small animal cardiopulmonary system using digital subtraction angiography

    Energy Technology Data Exchange (ETDEWEB)

    Lin Mingde; Marshall, Craig T.; Qi, Yi; Johnston, Samuel M.; Badea, Cristian T.; Piantadosi, Claude A.; Johnson, G. Allan [Department of Radiology, Center for In Vivo Microscopy and Department of Biomedical Engineering, Duke University Medical Center, Box 3302, Durham, North Carolina 27710 (United States); Division of Pulmonary and Critical Care Medicine and Center for Hyperbaric Medicine and Environmental Physiology, Duke University Medical Center, Box 3823, Durham, North Carolina 27710 (United States); Department of Radiology, Center for In Vivo Microscopy, Duke University Medical Center, Box 3302, Durham, North Carolina 27710 (United States); Department of Radiology, Center for In Vivo Microscopy and Department of Biomedical Engineering, Duke University Medical Center, Box 3302, Durham, North Carolina 27710 (United States); Department of Radiology, Center for In Vivo Microscopy, Duke University Medical Center, Box 3302, Durham, North Carolina 27710 (United States); Division of Pulmonary and Critical Care Medicine and Center for Hyperbaric Medicine and Environmental Physiology, Duke University Medical Center, Box 3823, Durham, North Carolina 27710 (United States); Department of Radiology, Center for In Vivo Microscopy and Department of Biomedical Engineering, Duke University Medical Center, Box 3302, Durham, North Carolina 27710 (United States)

    2009-11-15

    Purpose: The use of preclinical rodent models of disease continues to grow because these models help elucidate pathogenic mechanisms and provide robust test beds for drug development. Among the major anatomic and physiologic indicators of disease progression and genetic or drug modification of responses are measurements of blood vessel caliber and flow. Moreover, cardiopulmonary blood flow is a critical indicator of gas exchange. Current methods of measuring cardiopulmonary blood flow suffer from some or all of the following limitations--they produce relative values, are limited to global measurements, do not provide vasculature visualization, are not able to measure acute changes, are invasive, or require euthanasia. Methods: In this study, high-spatial and high-temporal resolution x-ray digital subtraction angiography (DSA) was used to obtain vasculature visualization, quantitative blood flow in absolute metrics (ml/min instead of arbitrary units or velocity), and relative blood volume dynamics from discrete regions of interest on a pixel-by-pixel basis (100x100 {mu}m{sup 2}). Results: A series of calibrations linked the DSA flow measurements to standard physiological measurement using thermodilution and Fick's method for cardiac output (CO), which in eight anesthetized Fischer-344 rats was found to be 37.0{+-}5.1 ml/min. Phantom experiments were conducted to calibrate the radiographic density to vessel thickness, allowing a link of DSA cardiac output measurements to cardiopulmonary blood flow measurements in discrete regions of interest. The scaling factor linking relative DSA cardiac output measurements to the Fick's absolute measurements was found to be 18.90xCO{sub DSA}=CO{sub Fick}. Conclusions: This calibrated DSA approach allows repeated simultaneous visualization of vasculature and measurement of blood flow dynamics on a regional level in the living rat.

  18. Quantitative blood flow measurements in the small animal cardiopulmonary system using digital subtraction angiography

    International Nuclear Information System (INIS)

    Lin Mingde; Marshall, Craig T.; Qi, Yi; Johnston, Samuel M.; Badea, Cristian T.; Piantadosi, Claude A.; Johnson, G. Allan

    2009-01-01

    Purpose: The use of preclinical rodent models of disease continues to grow because these models help elucidate pathogenic mechanisms and provide robust test beds for drug development. Among the major anatomic and physiologic indicators of disease progression and genetic or drug modification of responses are measurements of blood vessel caliber and flow. Moreover, cardiopulmonary blood flow is a critical indicator of gas exchange. Current methods of measuring cardiopulmonary blood flow suffer from some or all of the following limitations--they produce relative values, are limited to global measurements, do not provide vasculature visualization, are not able to measure acute changes, are invasive, or require euthanasia. Methods: In this study, high-spatial and high-temporal resolution x-ray digital subtraction angiography (DSA) was used to obtain vasculature visualization, quantitative blood flow in absolute metrics (ml/min instead of arbitrary units or velocity), and relative blood volume dynamics from discrete regions of interest on a pixel-by-pixel basis (100x100 μm 2 ). Results: A series of calibrations linked the DSA flow measurements to standard physiological measurement using thermodilution and Fick's method for cardiac output (CO), which in eight anesthetized Fischer-344 rats was found to be 37.0±5.1 ml/min. Phantom experiments were conducted to calibrate the radiographic density to vessel thickness, allowing a link of DSA cardiac output measurements to cardiopulmonary blood flow measurements in discrete regions of interest. The scaling factor linking relative DSA cardiac output measurements to the Fick's absolute measurements was found to be 18.90xCO DSA =CO Fick . Conclusions: This calibrated DSA approach allows repeated simultaneous visualization of vasculature and measurement of blood flow dynamics on a regional level in the living rat.

  19. Reliability and Validity of Digital Imagery Methodology for Measuring Starting Portions and Plate Waste from School Salad Bars.

    Science.gov (United States)

    Bean, Melanie K; Raynor, Hollie A; Thornton, Laura M; Sova, Alexandra; Dunne Stewart, Mary; Mazzeo, Suzanne E

    2018-04-12

    Scientifically sound methods for investigating dietary consumption patterns from self-serve salad bars are needed to inform school policies and programs. To examine the reliability and validity of digital imagery for determining starting portions and plate waste of self-serve salad bar vegetables (which have variable starting portions) compared with manual weights. In a laboratory setting, 30 mock salads with 73 vegetables were made, and consumption was simulated. Each component (initial and removed portion) was weighed; photographs of weighed reference portions and pre- and post-consumption mock salads were taken. Seven trained independent raters visually assessed images to estimate starting portions to the nearest ¼ cup and percentage consumed in 20% increments. These values were converted to grams for comparison with weighed values. Intraclass correlations between weighed and digital imagery-assessed portions and plate waste were used to assess interrater reliability and validity. Pearson's correlations between weights and digital imagery assessments were also examined. Paired samples t tests were used to evaluate mean differences (in grams) between digital imagery-assessed portions and measured weights. Interrater reliabilities were excellent for starting portions and plate waste with digital imagery. For accuracy, intraclass correlations were moderate, with lower accuracy for determining starting portions of leafy greens compared with other vegetables. However, accuracy of digital imagery-assessed plate waste was excellent. Digital imagery assessments were not significantly different from measured weights for estimating overall vegetable starting portions or waste; however, digital imagery assessments slightly underestimated starting portions (by 3.5 g) and waste (by 2.1 g) of leafy greens. This investigation provides preliminary support for use of digital imagery in estimating starting portions and plate waste from school salad bars. Results might inform

  20. The effect of pitch, rhythm, and familiarity on working memory and anxiety as measured by digit recall performance.

    Science.gov (United States)

    Silverman, Michael J

    2010-01-01

    The purpose of this study was to isolate and quantitatively evaluate the effects of pitch and rhythm of unfamiliar and familiar melodies on working memory and anxiety as measured by sequential digit recall performance. Participants (N = 60) listened to 6 treatment conditions each consisting of 9 randomized monosyllabic digits. The digits were paired with (a) a familiar melody and pitch only, (b) a familiar melody and rhythm only, (c) a familiar melody with both pitch and rhythm, (d) an unfamiliar melody with pitch only, (e) an unfamiliar melody with rhythm only, and (f) an unfamiliar melody with both pitch and rhythm. The 6 different treatments were counterbalanced using a Latin square design in an attempt to control for order effects. Participants rated their state anxiety on a Likert-type scale before, midway through, and after the digits test. No statistically significant order, learning, or practice effects were found. A 3-way repeated-measures ANOVA indicated a statistically significant difference in digit recall performance across musical element conditions and groups. Results indicated that music majors outperformed nonmusic majors on the digit recall task. Participants were able to recall digits from the rhythm condition most accurately while recalling digits from pitch only and both pitch and rhythm conditions the least accurately. Graphic analysis of treatment as a function of sequential position indicated digit recall was best during conditions of primacy and recency. No main effects were found for the familiarity condition. Additionally, no main effects or interactions were found for the anxiety variable. The results of this study are congruent with existing working memory and music literature suggesting that pairing information with rhythm can facilitate recall, music majors outperform non-music majors, and recall accuracy is best in positions of primacy and recency. Implications for practice in therapy and education are made as well as suggestions for

  1. Comparison of maximum intensity projection and digitally reconstructed radiographic projection for carotid artery stenosis measurement

    International Nuclear Information System (INIS)

    Hyde, Derek E.; Habets, Damiaan F.; Fox, Allan J.; Gulka, Irene; Kalapos, Paul; Lee, Don H.; Pelz, David M.; Holdsworth, David W.

    2007-01-01

    Digital subtraction angiography is being supplanted by three-dimensional imaging techniques in many clinical applications, leading to extensive use of maximum intensity projection (MIP) images to depict volumetric vascular data. The MIP algorithm produces intensity profiles that are different than conventional angiograms, and can also increase the vessel-to-tissue contrast-to-noise ratio. We evaluated the effect of the MIP algorithm in a clinical application where quantitative vessel measurement is important: internal carotid artery stenosis grading. Three-dimensional computed rotational angiography (CRA) was performed on 26 consecutive symptomatic patients to verify an internal carotid artery stenosis originally found using duplex ultrasound. These volumes of data were visualized using two different postprocessing projection techniques: MIP and digitally reconstructed radiographic (DRR) projection. A DRR is a radiographic image simulating a conventional digitally subtracted angiogram, but it is derived computationally from the same CRA dataset as the MIP. By visualizing a single volume with two different projection techniques, the postprocessing effect of the MIP algorithm is isolated. Vessel measurements were made, according to the NASCET guidelines, and percentage stenosis grades were calculated. The paired t-test was used to determine if the measurement difference between the two techniques was statistically significant. The CRA technique provided an isotropic voxel spacing of 0.38 mm. The MIPs and DRRs had a mean signal-difference-to-noise-ratio of 30:1 and 26:1, respectively. Vessel measurements from MIPs were, on average, 0.17 mm larger than those from DRRs (P<0.0001). The NASCET-type stenosis grades tended to be underestimated on average by 2.4% with the MIP algorithm, although this was not statistically significant (P=0.09). The mean interobserver variability (standard deviation) of both the MIP and DRR images was 0.35 mm. It was concluded that the MIP

  2. Effect of camera temperature variations on stereo-digital image correlation measurements

    KAUST Repository

    Pan, Bing

    2015-11-25

    In laboratory and especially non-laboratory stereo-digital image correlation (stereo-DIC) applications, the extrinsic and intrinsic parameters of the cameras used in the system may change slightly due to the camera warm-up effect and possible variations in ambient temperature. Because these camera parameters are generally calibrated once prior to measurements and considered to be unaltered during the whole measurement period, the changes in these parameters unavoidably induce displacement/strain errors. In this study, the effect of temperature variations on stereo-DIC measurements is investigated experimentally. To quantify the errors associated with camera or ambient temperature changes, surface displacements and strains of a stationary optical quartz glass plate with near-zero thermal expansion were continuously measured using a regular stereo-DIC system. The results confirm that (1) temperature variations in the cameras and ambient environment have a considerable influence on the displacements and strains measured by stereo-DIC due to the slightly altered extrinsic and intrinsic camera parameters; and (2) the corresponding displacement and strain errors correlate with temperature changes. For the specific stereo-DIC configuration used in this work, the temperature-induced strain errors were estimated to be approximately 30–50 με/°C. To minimize the adverse effect of camera temperature variations on stereo-DIC measurements, two simple but effective solutions are suggested.

  3. Effect of camera temperature variations on stereo-digital image correlation measurements

    KAUST Repository

    Pan, Bing; Shi, Wentao; Lubineau, Gilles

    2015-01-01

    In laboratory and especially non-laboratory stereo-digital image correlation (stereo-DIC) applications, the extrinsic and intrinsic parameters of the cameras used in the system may change slightly due to the camera warm-up effect and possible variations in ambient temperature. Because these camera parameters are generally calibrated once prior to measurements and considered to be unaltered during the whole measurement period, the changes in these parameters unavoidably induce displacement/strain errors. In this study, the effect of temperature variations on stereo-DIC measurements is investigated experimentally. To quantify the errors associated with camera or ambient temperature changes, surface displacements and strains of a stationary optical quartz glass plate with near-zero thermal expansion were continuously measured using a regular stereo-DIC system. The results confirm that (1) temperature variations in the cameras and ambient environment have a considerable influence on the displacements and strains measured by stereo-DIC due to the slightly altered extrinsic and intrinsic camera parameters; and (2) the corresponding displacement and strain errors correlate with temperature changes. For the specific stereo-DIC configuration used in this work, the temperature-induced strain errors were estimated to be approximately 30–50 με/°C. To minimize the adverse effect of camera temperature variations on stereo-DIC measurements, two simple but effective solutions are suggested.

  4. Electrical crosstalk-coupling measurement and analysis for digital closed loop fibre optic gyro

    International Nuclear Information System (INIS)

    Jing, Jin; Hai-Ting, Tian; Xiong, Pan; Ning-Fang, Song

    2010-01-01

    The phase modulation and the closed-loop controller can generate electrical crosstalk-coupling in digital closed-loop fibre optic gyro. Four electrical cross-coupling paths are verified by the open-loop testing approach. It is found the variation of ramp amplitude will lead to the alternation of gyro bias. The amplitude and the phase parameters of the electrical crosstalk signal are measured by lock-in amplifier, and the variation of gyro bias is confirmed to be caused by the alternation of phase according to the amplitude of the ramp. A digital closed-loop fibre optic gyro electrical crosstalk-coupling model is built by approximating the electrical cross-coupling paths as a proportion and integration segment. The results of simulation and experiment show that the modulation signal electrical crosstalk-coupling can cause the dead zone of the gyro when a small angular velocity is inputted, and it could also lead to a periodic vibration of the bias error of the gyro when a large angular velocity is inputted

  5. Pneumothorax size measurements on digital chest radiographs: Intra- and inter- rater reliability.

    Science.gov (United States)

    Thelle, Andreas; Gjerdevik, Miriam; Grydeland, Thomas; Skorge, Trude D; Wentzel-Larsen, Tore; Bakke, Per S

    2015-10-01

    Detailed and reliable methods may be important for discussions on the importance of pneumothorax size in clinical decision-making. Rhea's method is widely used to estimate pneumothorax size in percent based on chest X-rays (CXRs) from three measure points. Choi's addendum is used for anterioposterior projections. The aim of this study was to examine the intrarater and interrater reliability of the Rhea and Choi method using digital CXR in the ward based PACS monitors. Three physicians examined a retrospective series of 80 digital CXRs showing pneumothorax, using Rhea and Choi's method, then repeated in a random order two weeks later. We used the analysis of variance technique by Eliasziw et al. to assess the intrarater and interrater reliability in altogether 480 estimations of pneumothorax size. Estimated pneumothorax sizes ranged between 5% and 100%. The intrarater reliability coefficient was 0.98 (95% one-sided lower-limit confidence interval C 0.96), and the interrater reliability coefficient was 0.95 (95% one-sided lower-limit confidence interval 0.93). This study has shown that the Rhea and Choi method for calculating pneumothorax size has high intrarater and interrater reliability. These results are valid across gender, side of pneumothorax and whether the patient is diagnosed with primary or secondary pneumothorax. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  6. A Unified Framework for Measuring Stewardship Practices Applied to Digital Environmental Datasets

    Directory of Open Access Journals (Sweden)

    Ge Peng

    2015-01-01

    Full Text Available This paper presents a stewardship maturity assessment model in the form of a matrix for digital environmental datasets. Nine key components are identified based on requirements imposed on digital environmental data and information that are cared for and disseminated by U.S. Federal agencies by U.S. law, i.e., Information Quality Act of 2001, agencies’ guidance, expert bodies’ recommendations, and users. These components include: preservability, accessibility, usability, production sustainability, data quality assurance, data quality control/monitoring, data quality assessment, transparency/traceability, and data integrity. A five-level progressive maturity scale is then defined for each component associated with measurable practices applied to individual datasets, representing Ad Hoc, Minimal, Intermediate, Advanced, and Optimal stages. The rationale for each key component and its maturity levels is described. This maturity model, leveraging community best practices and standards, provides a unified framework for assessing scientific data stewardship. It can be used to create a stewardship maturity scoreboard of dataset(s and a roadmap for scientific data stewardship improvement or to provide data quality and usability information to users, stakeholders, and decision makers.

  7. Measurements of simulated periodontal bone defects in inverted digital image and film-based radiograph: an in vitro study

    International Nuclear Information System (INIS)

    Molon, Rafael Scaf; Morais Camillo, Juliana Aparecida Najarro Dearo; Ferreira, Mauricio Goncalves; Loffredo, Leonor Castro Monteiro; Scaf, Gulnara; Sakakura, Celso Eduardo

    2012-01-01

    This study was performed to compare the inverted digital images and film-based images of dry pig mandibles to measure the periodontal bone defect depth. Forty 2-wall bone defects were made in the proximal region of the premolar in the dry pig mandibles. The digital and conventional radiographs were taken using a Schick sensor and Kodak F-speed intraoral film. Image manipulation (inversion) was performed using Adobe Photoshop 7.0 software. Four trained examiners made all of the radiographic measurements in millimeters a total of three times from the cementoenamel junction to the most apical extension of the bone loss with both types of images: inverted digital and film. The measurements were also made in dry mandibles using a periodontal probe and digital caliper. The Student's t-test was used to compare the depth measurements obtained from the two types of images and direct visual measurement in the dry mandibles. A significance level of 0.05 for a 95% confidence interval was used for each comparison. There was a significant difference between depth measurements in the inverted digital images and direct visual measurements (p>|t|=0.0039), with means of 6.29 mm (IC 95% :6.04-6.54) and 6.79 mm (IC 95% :6.45-7.11), respectively. There was a non-significant difference between the film-based radiographs and direct visual measurements (p>|t|=0.4950), with means of 6.64 mm(IC 95% :6.40-6.89) and 6.79 mm(IC 95% :6.45-7.11), respectively. The periodontal bone defect measurements in the inverted digital images were inferior to film-based radiographs, underestimating the amount of bone loss.

  8. Measurements of simulated periodontal bone defects in inverted digital image and film-based radiograph: an in vitro study

    Energy Technology Data Exchange (ETDEWEB)

    Molon, Rafael Scaf; Morais Camillo, Juliana Aparecida Najarro Dearo; Ferreira, Mauricio Goncalves; Loffredo, Leonor Castro Monteiro; Scaf, Gulnara [Araraquara Dental School, Universidade Estadual Paulista, Sao Paulo (Brazil); Sakakura, Celso Eduardo [Barretos Dental School, Barretos Educational Fundation, Sao Paulo (Brazil)

    2012-09-15

    This study was performed to compare the inverted digital images and film-based images of dry pig mandibles to measure the periodontal bone defect depth. Forty 2-wall bone defects were made in the proximal region of the premolar in the dry pig mandibles. The digital and conventional radiographs were taken using a Schick sensor and Kodak F-speed intraoral film. Image manipulation (inversion) was performed using Adobe Photoshop 7.0 software. Four trained examiners made all of the radiographic measurements in millimeters a total of three times from the cementoenamel junction to the most apical extension of the bone loss with both types of images: inverted digital and film. The measurements were also made in dry mandibles using a periodontal probe and digital caliper. The Student's t-test was used to compare the depth measurements obtained from the two types of images and direct visual measurement in the dry mandibles. A significance level of 0.05 for a 95% confidence interval was used for each comparison. There was a significant difference between depth measurements in the inverted digital images and direct visual measurements (p>|t|=0.0039), with means of 6.29 mm (IC{sub 95%}:6.04-6.54) and 6.79 mm (IC{sub 95%}:6.45-7.11), respectively. There was a non-significant difference between the film-based radiographs and direct visual measurements (p>|t|=0.4950), with means of 6.64 mm(IC{sub 95%}:6.40-6.89) and 6.79 mm(IC{sub 95%}:6.45-7.11), respectively. The periodontal bone defect measurements in the inverted digital images were inferior to film-based radiographs, underestimating the amount of bone loss.

  9. Bilateral renal calculi

    Science.gov (United States)

    Sreenevasan, G

    1974-01-01

    Bilateral renal calculi were present in 114 (10.7%) of 1,070 cases of proved urinary calculus admitted to the Urological Department of the General Hospital, Kuala Lumpur, during the period November 1968—May 1973. The management of bilateral renal calculi is discussed with reference to the first 100 cases in this series. The introduction of renography has greatly facilitated the decision as to which kidney should be operated on first. The management of patients with and without uraemia is discussed and the use of the modified V and V—Y incisions for the removal of staghorn calculi is described. Complications and results are briefly reviewed. ImagesFig. 1Fig. 4Fig. 6Fig. 7 PMID:4845653

  10. Bilateral chronic subdural hematoma

    DEFF Research Database (Denmark)

    Andersen-Ranberg, Nina Christine; Rom Poulsen, Frantz; Bergholt, Bo

    2017-01-01

    OBJECTIVE Bilateral chronic subdural hematoma (bCSDH) is a common neurosurgical condition frequently associated with the need for retreatment. The reason for the high rate of retreatment has not been thoroughly investigated. Thus, the authors focused on determining which independent predictors...... are associated with the retreatment of bCSDH with a focus on surgical laterality. METHODS In a national database of CSDHs (Danish Chronic Subdural Hematoma Study) the authors retrospectively identified all bCSDHs treated in the 4 Danish neurosurgical departments over the 3-year period from 2010 to 2012...... that a separated hematoma density and the absence of postoperative drainage were independent predictors of retreatment. CONCLUSIONS In bCSDHs bilateral surgical intervention significantly lowers the risk of retreatment compared with unilateral intervention and should be considered when choosing a surgical...

  11. Bilateral Wilms' tumor

    International Nuclear Information System (INIS)

    Malcolm, A.W.; Jaffe, N.; Folkman, M.J.; Cassady, J.R.

    1980-01-01

    Twenty children with bilateral Wilms' tumor were presented to the Children's Hospital Medical Center and Children's Cancer Research Foundation, Sidney Farber Cancer Institute, and Joint Center for Radiation Therapy (CHMC-CCRF, SFCI, JCRT) from January 1, 1956 to December 31, 1976. Of these 20, 16 had simultaneous and 4 had metachronous disease on presentation. All patients were treated with surgery, radiation and chemotherapy. Of the 16 patients with simultaneous disease, 10 (63%) are alive and free of disease 12+ to 175+ months post diagnosis and treatment, with median follow-up of 121 months. There were no long-term survivors in the metachronous group; all were dead of disease within 21 months from initial presentation of original tumor. With these data we relate prognosis to extent of disease and discuss a general approach to the management of bilateral Wilms' tumor

  12. Multilateral and bilateral agreements

    International Nuclear Information System (INIS)

    Koponen, H.

    1993-01-01

    Finland has made both multilateral and bilateral agreements on the exchange of information related to radiation safety. The first arrangements for international agreements and exchange of information were made after the Chernobyl accident. In 1987, Finland joined the convention on early notification of a nuclear power accident coordinated by International Atomic Energy Agency. The convention is applied to accidents that cause of may cause emissions of radioactive substances that might affect the radiation safety of another country. Besides the convention on early notification, some other individual agreements have also been made. These include the International Nuclear Event Scale (INES) system and power companies own information exchange systems. Finland has conducted bilateral agreements with the Nordic countries and the Soviet Union on the notification of accidents and exchange of nuclear power plant information. Today, Russia answers for the Soviet Union's contractual obligations. (orig.)

  13. Adaptive digital fringe projection technique for high dynamic range three-dimensional shape measurement.

    Science.gov (United States)

    Lin, Hui; Gao, Jian; Mei, Qing; He, Yunbo; Liu, Junxiu; Wang, Xingjin

    2016-04-04

    It is a challenge for any optical method to measure objects with a large range of reflectivity variation across the surface. Image saturation results in incorrect intensities in captured fringe pattern images, leading to phase and measurement errors. This paper presents a new adaptive digital fringe projection technique which avoids image saturation and has a high signal to noise ratio (SNR) in the three-dimensional (3-D) shape measurement of objects that has a large range of reflectivity variation across the surface. Compared to previous high dynamic range 3-D scan methods using many exposures and fringe pattern projections, which consumes a lot of time, the proposed technique uses only two preliminary steps of fringe pattern projection and image capture to generate the adapted fringe patterns, by adaptively adjusting the pixel-wise intensity of the projected fringe patterns based on the saturated pixels in the captured images of the surface being measured. For the bright regions due to high surface reflectivity and high illumination by the ambient light and surfaces interreflections, the projected intensity is reduced just to be low enough to avoid image saturation. Simultaneously, the maximum intensity of 255 is used for those dark regions with low surface reflectivity to maintain high SNR. Our experiments demonstrate that the proposed technique can achieve higher 3-D measurement accuracy across a surface with a large range of reflectivity variation.

  14. Bilateral renal artery variation

    OpenAIRE

    Üçerler, Hülya; Üzüm, Yusuf; İkiz, Z. Aslı Aktan

    2014-01-01

    Each kidney is supplied by a single renal artery, although renal artery variations are common. Variations of the renal arteryhave become important with the increasing number of renal transplantations. Numerous studies describe variations in renalartery anatomy. Especially the left renal artery is among the most critical arterial variations, because it is the referred side forresecting the donor kidney. During routine dissection in a formalin fixed male cadaver, we have found a bilateral renal...

  15. File: International bilateral relations

    International Nuclear Information System (INIS)

    Feltin, Ch.; Rabouhams, J.; Bravo, X.; Rousseau, M.; Le Breton, S.; Saint Raymond, Ph.; Brigaud, O.; Pertuis, V.; McNair, J.; Sayers, M.R.; Bye, R.; Scherrer, J.

    1998-01-01

    Since its creation in 1973, the Authority of Safety was assigned missions in the international field with following objectives: to develop information exchanges with its foreign counterpart, to make know and to explain the French approach and practice; to give to concerned countries the useful information on french nuclear facilities situated near the border; This file shows with some examples, how bilateral relations allow to fill up these objectives and how the French Authority got the foreign experience. (N.C.)

  16. A simplified, improved method for making amplifier equivalent noise charge measurements using a new generation digitizing oscilloscope

    International Nuclear Information System (INIS)

    Zimmerman, T.

    1990-10-01

    Historically a variety of methods have been used to measure the equivalent noise charge (ENC) of amplifier/shaper systems for high energy physics. Some of these methods require several pieces of special test equipment and a fair amount of effort. The advent of digitizing oscilloscopes with statistics capabilities makes it possible to perform certain types of noise measurements accurately with very little effort. This paper describes the noise measurement method of a time invariant amplifier/shaper and of a time variant correlated sampling system, using a Tektronix DSA602 Digitizing Signal Analyzer. 4 figs

  17. Virtual instrumentation technique used in the nuclear digital signal processing system design: Energy and time measurement tests

    International Nuclear Information System (INIS)

    Pechousek, J.; Prochazka, R.; Prochazka, V.; Frydrych, J.

    2011-01-01

    In this report, computer-based digital signal processing system with a 200 MS s -1 sampling digitizer is presented. Virtual instrumentation technique is used to easily develop a system which provides spectroscopy measurements such as amplitude and time signal analysis, with the time-of-flight facility. Several test measurements were performed to determine the characteristics of a system. The presented system may find its application in the coincidence measurement since the system is usable for different types of detectors and sensitive to decay lifetimes from tens of nanoseconds to seconds.

  18. Idiopathic bilateral male breast abscess.

    Science.gov (United States)

    Sinha, Rajan Kumar; Sinha, Mithilesh Kumar; Gaurav, Kumar; Kumar, Amar

    2014-03-10

    A 38-year-old man presented with bilateral breast swelling, along with pain and redness for 7 days. Bilateral axillary nodes were also palpable; which were multiple and discrete. A provisional diagnosis of bilateral breast abscess was made with suspicion of underlying malignancy. Incision and drainage through subareolar incision was performed and the adjoining tissue was excised and sent for histopathological examination.

  19. Local liquid velocity measurement of Trickle Bed Reactor using Digital Industrial X-ray Radiography

    Science.gov (United States)

    Mohd Salleh, Khairul Anuar

    Trickle Bed Reactors (TBRs) are fixed beds of particles in which both liquid and gas flow concurrently downward. They are widely used to produce not only fuels but also lubrication products. The measurement and the knowledge of local liquid velocities (VLL) in TBRs is less which is essential for advancing the understanding of its hydrodynamics and for validation computational fluid dynamics (CFD). Therefore, this work focused on developing a new, non-invasive, statistically reliable technique that can be used to measure local liquid velocity (VLL) in two-dimensions (2-D). This is performed by combining Digital Industrial X-ray Radiography (DIR) and Particle Tracking Velocimetry (PTV) techniques. This work also make possible the development of three-dimensional (3-D) VLL measurements that can be taken in TBRs. Measurements taken through both the combined and the novel technique, once validated, were found to be comparable to another technique (a two-point fiber optical probe) currently being developed at Missouri University of Science and Technology. The results from this study indicate that, for a gas-liquid-solid type bed, the measured VLL can have a maximum range that is between 35 and 51 times that of its superficial liquid velocity (VSL). Without the existence of gas, the measured VLL can have a maximum range that is between 4 and 4.7 times that of its VSL. At a higher V SL, the particle tracer was greatly distributed and became carried away by a high liquid flow rate. Neither the variance nor the range of measured VLL varied for any of the replications, confirming the reproducibility of the experimental measurements used, regardless of the VSL . The liquid's movement inside the pore was consistent with findings from previous studies that used various techniques.

  20. Digital image integration technique of multi-geoscience information dominated by aerial radiometric measurements

    International Nuclear Information System (INIS)

    Liu Dechang; Sun Maorong; Zhu Deling; Zhang Jingbo; He Jianguo; Dong Xiuzhen

    1992-02-01

    The geologic metallogenetic environment of uranium at Lian Shan Guan region has been studied by using digital image integration technique of multi-geoscience information with aerial radiometric measurements. It includes the classification of uranium-bearing rock, recognizing patterns of ore-forming and geologic mapping in ore field. Some new tectonic structure was found in this region that gives significant information for further exploring of uranium ore. After multi-parameters screening of aerial radiometric data, patterns recognizing and multi-geoscience information integration analysis, four prospective metallogenetic zones were predicted, and the predication was proved by further geologic survey. Three of the four zones are very encouraging, where ore-forming structures, hydrothermal deposits, wall-rock alteration, primary and secondary uranium ore and rich uranium mineralization are discovered. The department of geologic exploring has decided that these zones will enjoy priority in the examination for further prospecting of uranium ores

  1. Using digital images to measure and discriminate small particles in cotton

    Science.gov (United States)

    Taylor, Robert A.; Godbey, Luther C.

    1991-02-01

    Inages from conventional video systems are being digitized in coraputers for the analysis of small trash particles in cotton. The method has been developed to automate particle counting and area measurements for bales of cotton prepared for market. Because the video output is linearly proportional to the amount of light reflected the best spectral band for optimum particle discrimination should be centered at the wavelength of maximum difference between particles and their surroundings. However due to the spectral distribution of the illumination energy and the detector sensitivity peak image performance bands were altered. Reflectance from seven mechanically cleaned cotton lint samples and trash removed were examined for spectral contrast in the wavelength range of camera sensitivity. Pixel intensity histograms from the video systent are reported for simulated trashmeter area reference samples (painted dots on panels) and for cotton containing trash to demonstrate the particle discrimination mechanism. 2.

  2. Is digital photography an accurate and precise method for measuring range of motion of the hip and knee?

    Science.gov (United States)

    Russo, Russell R; Burn, Matthew B; Ismaily, Sabir K; Gerrie, Brayden J; Han, Shuyang; Alexander, Jerry; Lenherr, Christopher; Noble, Philip C; Harris, Joshua D; McCulloch, Patrick C

    2017-09-07

    Accurate measurements of knee and hip motion are required for management of musculoskeletal pathology. The purpose of this investigation was to compare three techniques for measuring motion at the hip and knee. The authors hypothesized that digital photography would be equivalent in accuracy and show higher precision compared to the other two techniques. Using infrared motion capture analysis as the reference standard, hip flexion/abduction/internal rotation/external rotation and knee flexion/extension were measured using visual estimation, goniometry, and photography on 10 fresh frozen cadavers. These measurements were performed by three physical therapists and three orthopaedic surgeons. Accuracy was defined by the difference from the reference standard, while precision was defined by the proportion of measurements within either 5° or 10°. Analysis of variance (ANOVA), t-tests, and chi-squared tests were used. Although two statistically significant differences were found in measurement accuracy between the three techniques, neither of these differences met clinical significance (difference of 1.4° for hip abduction and 1.7° for the knee extension). Precision of measurements was significantly higher for digital photography than: (i) visual estimation for hip abduction and knee extension, and (ii) goniometry for knee extension only. There was no clinically significant difference in measurement accuracy between the three techniques for hip and knee motion. Digital photography only showed higher precision for two joint motions (hip abduction and knee extension). Overall digital photography shows equivalent accuracy and near-equivalent precision to visual estimation and goniometry.

  3. The influence of institutional measures and technological proficiency on university teaching through digital platforms

    Directory of Open Access Journals (Sweden)

    Tirado, Ramón

    2012-06-01

    Full Text Available The objective of this study is to empirically test the theoretical model that explains the influence of primary and secondary factors on the integration of digital platforms in university teaching. A sample of 495 teachers from universities in Andalusia completed an online questionnaire that analysed the functions of usage, the digital materials used, the didactic and technological competence of the teaching staff, the support measures adopted by the institutions and the effect on teaching of platform use. Prior factor analysis and the application of the Amos program enabled us to develop a structural equation model to corroborate the indirect influence of the support measures and institutional recognition on teachers in their use of the platforms, and the direct influence of the teachers’ technological proficiency. Este estudio tiene como objetivo poner a prueba empíricamente el modelo teórico que explica la influencia de los factores de primer y segundo orden sobre la integración de las plataformas digitales en la docencia universitaria. Para ello, sobre una muestra de 495 profesores universitarios andaluces, se aplica un cuestionario online que analiza las funciones de uso, materiales digitales utilizados, competencia didáctica y tecnológica del profesorado, medidas de impulso institucionales, y efectos didácticos del uso. El análisis factorial previo y la aplicación del programa Amos permite la elaboración un modelo de ecuación estructural que corrobora la influencia indirecta de las medidas de apoyo y el reconocimiento institucional sobre los efectos didácticos del uso de plataformas, así como la influencia directa de la competencia tecnológica del profesorado.

  4. The Affective Slider: A Digital Self-Assessment Scale for the Measurement of Human Emotions.

    Directory of Open Access Journals (Sweden)

    Alberto Betella

    Full Text Available Self-assessment methods are broadly employed in emotion research for the collection of subjective affective ratings. The Self-Assessment Manikin (SAM, a pictorial scale developed in the eighties for the measurement of pleasure, arousal, and dominance, is still among the most popular self-reporting tools, despite having been conceived upon design principles which are today obsolete. By leveraging on state-of-the-art user interfaces and metacommunicative pictorial representations, we developed the Affective Slider (AS, a digital self-reporting tool composed of two slider controls for the quick assessment of pleasure and arousal. To empirically validate the AS, we conducted a systematic comparison between AS and SAM in a task involving the emotional assessment of a series of images taken from the International Affective Picture System (IAPS, a database composed of pictures representing a wide range of semantic categories often used as a benchmark in psychological studies. Our results show that the AS is equivalent to SAM in the self-assessment of pleasure and arousal, with two added advantages: the AS does not require written instructions and it can be easily reproduced in latest-generation digital devices, including smartphones and tablets. Moreover, we compared new and normative IAPS ratings and found a general drop in reported arousal of pictorial stimuli. Not only do our results demonstrate that legacy scales for the self-report of affect can be replaced with new measurement tools developed in accordance to modern design principles, but also that standardized sets of stimuli which are widely adopted in research on human emotion are not as effective as they were in the past due to a general desensitization towards highly arousing content.

  5. The Affective Slider: A Digital Self-Assessment Scale for the Measurement of Human Emotions.

    Science.gov (United States)

    Betella, Alberto; Verschure, Paul F M J

    2016-01-01

    Self-assessment methods are broadly employed in emotion research for the collection of subjective affective ratings. The Self-Assessment Manikin (SAM), a pictorial scale developed in the eighties for the measurement of pleasure, arousal, and dominance, is still among the most popular self-reporting tools, despite having been conceived upon design principles which are today obsolete. By leveraging on state-of-the-art user interfaces and metacommunicative pictorial representations, we developed the Affective Slider (AS), a digital self-reporting tool composed of two slider controls for the quick assessment of pleasure and arousal. To empirically validate the AS, we conducted a systematic comparison between AS and SAM in a task involving the emotional assessment of a series of images taken from the International Affective Picture System (IAPS), a database composed of pictures representing a wide range of semantic categories often used as a benchmark in psychological studies. Our results show that the AS is equivalent to SAM in the self-assessment of pleasure and arousal, with two added advantages: the AS does not require written instructions and it can be easily reproduced in latest-generation digital devices, including smartphones and tablets. Moreover, we compared new and normative IAPS ratings and found a general drop in reported arousal of pictorial stimuli. Not only do our results demonstrate that legacy scales for the self-report of affect can be replaced with new measurement tools developed in accordance to modern design principles, but also that standardized sets of stimuli which are widely adopted in research on human emotion are not as effective as they were in the past due to a general desensitization towards highly arousing content.

  6. CAMAC system for data acquisition on output of digital panel meter for DC voltage measurement

    International Nuclear Information System (INIS)

    Noda, Nobuaki.

    1979-03-01

    An interface between the digital panel meter (DPM) for DC voltage measurement and the CAMAC system for T-2 experiment in JIPP (Japan Institute of Plasma Physics) was designed and produced. This panel meter is used for the purpose of monitoring the deflected electrode voltage of a 6 channel, neutral particle, energy analyzer (parallel plate electrodes, electro static type). The method of connecting the DPM to the CAMAC system is that of taking the gate pulses with the width proportional to the voltage to be measured out of the output of the DPM and counting the clock pulses. This system uses each one channel of output register, interrupting register, scaler and clock generator, and the binary digital data is obtained in the scaler, and sent to the main memory of the computer HITAC 10-2 through the CAMAC crate controller. At this time, the interface gives the output of the gate pulses with the width proportional to the DPM input voltage from the DPM BUSY output and PRINT COMMAND output, depending on the sampling pulses from the output register. The interface also gives the end pulse communicating the completion of the output of gate pulses to the interrupting register. The software is summarized in the flow chart of the program and in the program list used for the test on this data acquisition system. The features of this system are to be able to obtain the binary data directly, and to be capable of saving the number of transmission lines required for data transfer. (Wakatsuki, Y.)

  7. Application of digital image correlation for long-distance bridge deflection measurement

    Science.gov (United States)

    Tian, Long; Pan, Bing; Cai, Youfa; Liang, Hui; Zhao, Yan

    2013-06-01

    Due to its advantages of non-contact, full-field and high-resolution measurement, digital image correlation (DIC) method has gained wide acceptance and found numerous applications in the field of experimental mechanics. In this paper, the application of DIC for real-time long-distance bridge deflection detection in outdoor environments is studied. Bridge deflection measurement using DIC in outdoor environments is more challenging than regular DIC measurements performed under laboratory conditions. First, much more image noise due to variations in ambient light will be presented in the images recorded in outdoor environments. Second, how to select the target area becomes a key factor because long-distance imaging results in a large field of view of the test object. Finally, the image acquisition speed of the camera must be high enough (larger than 100 fps) to capture the real-time dynamic motion of a bridge. In this work, the above challenging issues are addressed and several improvements were made to DIC method. The applicability was demonstrated by real experiments. Experimental results indicate that the DIC method has great potentials in motion measurement in various large building structures.

  8. Testing digital safety system software with a testability measure based on a software fault tree

    International Nuclear Information System (INIS)

    Sohn, Se Do; Hyun Seong, Poong

    2006-01-01

    Using predeveloped software, a digital safety system is designed that meets the quality standards of a safety system. To demonstrate the quality, the design process and operating history of the product are reviewed along with configuration management practices. The application software of the safety system is developed in accordance with the planned life cycle. Testing, which is a major phase that takes a significant time in the overall life cycle, can be optimized if the testability of the software can be evaluated. The proposed testability measure of the software is based on the entropy of the importance of basic statements and the failure probability from a software fault tree. To calculate testability, a fault tree is used in the analysis of a source code. With a quantitative measure of testability, testing can be optimized. The proposed testability can also be used to demonstrate whether the test cases based on uniform partitions, such as branch coverage criteria, result in homogeneous partitions that is known to be more effective than random testing. In this paper, the testability measure is calculated for the modules of a nuclear power plant's safety software. The module testing with branch coverage criteria required fewer test cases if the module has higher testability. The result shows that the testability measure can be used to evaluate whether partitions have homogeneous characteristics

  9. Digital image processing based mass flow rate measurement of gas/solid two-phase flow

    Energy Technology Data Exchange (ETDEWEB)

    Song Ding; Peng Lihui; Lu Geng; Yang Shiyuan [Tsinghua National Laboratory for Information Science and Technology, Department of Automation, Tsinghua University, Beijing, 100084 (China); Yan Yong, E-mail: lihuipeng@tsinghua.edu.c [University of Kent, Canterbury, Kent CT2 7NT (United Kingdom)

    2009-02-01

    With the rapid growth of the process industry, pneumatic conveying as a tool for the transportation of a wide variety of pulverized and granular materials has become widespread. In order to improve plant control and operational efficiency, it is essential to know the parameters of the particle flow. This paper presents a digital imaging based method which is capable of measuring multiple flow parameters, including volumetric concentration, velocity and mass flow rate of particles in the gas/solid two phase flow. The measurement system consists of a solid state laser for illumination, a low-cost CCD camera for particle image acquisition and a microcomputer with bespoke software for particle image processing. The measurements of particle velocity and volumetric concentration share the same sensing hardware but use different exposure time and different image processing methods. By controlling the exposure time of the camera a clear image and a motion blurred image are obtained respectively. The clear image is thresholded by OTSU method to identify the particles from the dark background so that the volumetric concentration is determined by calculating the ratio between the particle area and the total area. Particle velocity is derived from the motion blur length, which is estimated from the motion blurred images by using the travelling wave equation method. The mass flow rate of particles is calculated by combining the particle velocity and volumetric concentration. Simulation and experiment results indicate that the proposed method is promising for the measurement of multiple parameters of gas/solid two-phase flow.

  10. Digital image processing based mass flow rate measurement of gas/solid two-phase flow

    International Nuclear Information System (INIS)

    Song Ding; Peng Lihui; Lu Geng; Yang Shiyuan; Yan Yong

    2009-01-01

    With the rapid growth of the process industry, pneumatic conveying as a tool for the transportation of a wide variety of pulverized and granular materials has become widespread. In order to improve plant control and operational efficiency, it is essential to know the parameters of the particle flow. This paper presents a digital imaging based method which is capable of measuring multiple flow parameters, including volumetric concentration, velocity and mass flow rate of particles in the gas/solid two phase flow. The measurement system consists of a solid state laser for illumination, a low-cost CCD camera for particle image acquisition and a microcomputer with bespoke software for particle image processing. The measurements of particle velocity and volumetric concentration share the same sensing hardware but use different exposure time and different image processing methods. By controlling the exposure time of the camera a clear image and a motion blurred image are obtained respectively. The clear image is thresholded by OTSU method to identify the particles from the dark background so that the volumetric concentration is determined by calculating the ratio between the particle area and the total area. Particle velocity is derived from the motion blur length, which is estimated from the motion blurred images by using the travelling wave equation method. The mass flow rate of particles is calculated by combining the particle velocity and volumetric concentration. Simulation and experiment results indicate that the proposed method is promising for the measurement of multiple parameters of gas/solid two-phase flow.

  11. Digital PIV Measurements of Acoustic Particle Displacements in a Normal Incidence Impedance Tube

    Science.gov (United States)

    Humphreys, William M., Jr.; Bartram, Scott M.; Parrott, Tony L.; Jones, Michael G.

    1998-01-01

    Acoustic particle displacements and velocities inside a normal incidence impedance tube have been successfully measured for a variety of pure tone sound fields using Digital Particle Image Velocimetry (DPIV). The DPIV system utilized two 600-mj Nd:YAG lasers to generate a double-pulsed light sheet synchronized with the sound field and used to illuminate a portion of the oscillatory flow inside the tube. A high resolution (1320 x 1035 pixel), 8-bit camera was used to capture double-exposed images of 2.7-micron hollow silicon dioxide tracer particles inside the tube. Classical spatial autocorrelation analysis techniques were used to ascertain the acoustic particle displacements and associated velocities for various sound field intensities and frequencies. The results show that particle displacements spanning a range of 1-60 microns can be measured for incident sound pressure levels of 100-130 dB and for frequencies spanning 500-1000 Hz. The ability to resolve 1 micron particle displacements at sound pressure levels in the 100 dB range allows the use of DPIV systems for measurement of sound fields at much lower sound pressure levels than had been previously possible. Representative impedance tube data as well as an uncertainty analysis for the measurements are presented.

  12. Comparison of a digital and an optical analogue hand-held refractometer for the measurement of canine urine specific gravity.

    Science.gov (United States)

    Paris, J K; Bennett, A D; Dodkin, S J; Gunn-Moore, D A

    2012-05-05

    Urine specific gravity (USG) is used clinically as a measure of urine concentration, and is routinely assessed by refractometry. A comparison between optical analogue and digital refractometers for evaluation of canine urine has not been reported. The aim of this study was to compare a digital and an optical analogue hand-held refractometer for the measurement of canine USG, and to assess correlation with urine osmolality. Prospective study. Free-catch urine samples were collected from 285 hospitalised adult dogs, and paired USG readings were obtained with a digital and an optical analogue refractometer. In 50 dogs, urine osmolality was also measured using a freezing point depression osmometer. There was a small but statistically significant difference between the two refractometers (P<0.001), with the optical analogue refractometer reading higher than the digital refractometer (mean difference 0.0006, sd 0.0012). Paired refractometer measurements varied by <0.002 in 91.5 per cent of cases. The optical analogue and digital refractometer readings showed excellent correlation with osmolality (r=0.980 and r=0.977, respectively, P<0.001 in both cases). Despite statistical significance, the difference between the two refractometers is unlikely to be clinically significant. Both instruments provide an accurate assessment of USG in dogs.

  13. Development of the Digital Health Literacy Instrument : Measuring a Broad Spectrum of Health 1.0 and Health 2.0 Skills

    NARCIS (Netherlands)

    van der Vaart, Rosalie; Drossaert, Constance

    2017-01-01

    Background: With the digitization of health care and the wide availability of Web-based applications, a broad set of skills is essential to properly use such facilities; these skills are called digital health literacy or eHealth literacy. Current instruments to measure digital health literacy focus

  14. Bilateral electric energy contracts: return and risk

    Energy Technology Data Exchange (ETDEWEB)

    Gunn, Laura K.; Silva, Elisa B.; Correia, Paulo B. [State University of Campinas (UNICAMP), SP (Brazil). College of Mechanical Engineering

    2009-07-01

    In Brazil electricity is traded through three segments: the spot market that balances offer and demand, with prices calculated by a cost-based computational model; the regulated market , where prices are settled in public auctions, and the free market for bilateral contracts. As spot and regulated market prices are public information, a seller is able to calculate his opportunity price to trade a bilateral contract in the free market by using the non-arbitrage principle. Thus, the seller searches the price of a bilateral contract in the free market that balances his/her revenues with the value expected in case it were negotiated in the regulated and the spot market. Besides the expected revenue, the seller may also consider the CVaR to measure the risk of her/his bilateral contract in the free market. So this paper develops a binomial lattice approach to price bilateral contracts in the free market, considering the seller's opportunity of negotiations in both regulated and spot markets, and measuring the contract risk directly. (author)

  15. Effect of out-of-plane specimen movement on strain measurement using digital-image-correlation-based video measurement in 2D and 3D

    DEFF Research Database (Denmark)

    Poling, Joel; Desai, Niranjan; Fischer, Gregor

    2018-01-01

    This study determined the effect of specimen out-of-plane movement relative to the sensor, on the accuracy of strains measured made applying 2D and 3D measurement approaches employing the state-of-the-art digital-image-correlation (DIC)-based tool iMETRUM. DIC provides a convenient and inexpensive...

  16. Assessment of novel digital and smartphone goniometers for measurement of canine stifle joint angles.

    Science.gov (United States)

    Freund, Kristin A; Kieves, Nina R; Hart, Juliette L; Foster, Sasha A; Jeffery, Unity; Duerr, Felix M

    2016-07-01

    OBJECTIVE To evaluate accuracy and reliability of 3 novel goniometers for measurement of canine stifle joint angles and compare the results with those obtained with a universal goniometer (UG). SAMPLE 8 pelvic limbs from 4 canine cadavers. PROCEDURES Each limb was secured to a wooden platform at 3 arbitrarily selected fixed stifle joint angles. Goniometry was performed with 2 smartphone-based applications (novel goniometers A and B), a digital goniometer (novel goniometer C), and a UG; 3 evaluators performed measurements in triplicate for each angle with each device. Results were compared with stifle joint angle measurements on radiographs (used as a gold standard). Accuracy was determined by calculation of bias and total error, coefficients of variation were calculated to estimate reliability, and strength of linear association between radiographic and goniometer measurements was assessed by calculation of correlation coefficients. RESULTS Mean coefficient of variation was lowest for the UG (4.88%), followed by novel goniometers B (7.37%), A (7.57%), and C (12.71%). Correlation with radiographic measurements was highest for the UG (r = 0.97), followed by novel goniometers B (0.93), A (0.90), and C (0.78). Constant bias was present for all devices except novel goniometer B. The UG and novel goniometer A had positive constant bias; novel goniometer C had negative constant bias. Total error at 50° and 100° angles was > 5% for all devices. CONCLUSIONS AND CLINICAL RELEVANCE None of the devices accurately represented radiographically measured stifle joint angles. Additional veterinary studies are indicated prior to the use of novel goniometers in dogs.

  17. Employing the Gini coefficient to measure participation inequality in treatment-focused Digital Health Social Networks.

    Science.gov (United States)

    van Mierlo, Trevor; Hyatt, Douglas; Ching, Andrew T

    2016-01-01

    Digital Health Social Networks (DHSNs) are common; however, there are few metrics that can be used to identify participation inequality. The objective of this study was to investigate whether the Gini coefficient, an economic measure of statistical dispersion traditionally used to measure income inequality, could be employed to measure DHSN inequality. Quarterly Gini coefficients were derived from four long-standing DHSNs. The combined data set included 625,736 posts that were generated from 15,181 actors over 18,671 days. The range of actors (8-2323), posts (29-28,684), and Gini coefficients (0.15-0.37) varied. Pearson correlations indicated statistically significant associations between number of actors and number of posts (0.527-0.835, p  addiction networks (0.619 and 0.276, p  networks ( t  = -4.305 and -5.934, p  network engagement. Further, mixed-methods research investigating quantitative performance metrics is required.

  18. Validity of the Symbol Digit Modalities Test as a cognition performance outcome measure for multiple sclerosis.

    Science.gov (United States)

    Benedict, Ralph Hb; DeLuca, John; Phillips, Glenn; LaRocca, Nicholas; Hudson, Lynn D; Rudick, Richard

    2017-04-01

    Cognitive and motor performance measures are commonly employed in multiple sclerosis (MS) research, particularly when the purpose is to determine the efficacy of treatment. The increasing focus of new therapies on slowing progression or reversing neurological disability makes the utilization of sensitive, reproducible, and valid measures essential. Processing speed is a basic elemental cognitive function that likely influences downstream processes such as memory. The Multiple Sclerosis Outcome Assessments Consortium (MSOAC) includes representatives from advocacy organizations, Food and Drug Administration (FDA), European Medicines Agency (EMA), National Institute of Neurological Disorders and Stroke (NINDS), academic institutions, and industry partners along with persons living with MS. Among the MSOAC goals is acceptance and qualification by regulators of performance outcomes that are highly reliable and valid, practical, cost-effective, and meaningful to persons with MS. A critical step for these neuroperformance metrics is elucidation of clinically relevant benchmarks, well-defined degrees of disability, and gradients of change that are deemed clinically meaningful. This topical review provides an overview of research on one particular cognitive measure, the Symbol Digit Modalities Test (SDMT), recognized as being particularly sensitive to slowed processing of information that is commonly seen in MS. The research in MS clearly supports the reliability and validity of this test and recently has supported a responder definition of SDMT change approximating 4 points or 10% in magnitude.

  19. Digital signal processing for velocity measurements in dynamical material's behaviour studies

    International Nuclear Information System (INIS)

    Devlaminck, Julien; Luc, Jerome; Chanal, Pierre-Yves

    2014-01-01

    In this work, we describe different configurations of optical fiber interferometers (types Michelson and Mach-Zehnder) used to measure velocities during dynamical material's behaviour studies. We detail the algorithms of processing developed and optimized to improve the performance of these interferometers especially in terms of time and frequency resolutions. Three methods of analysis of interferometric signals were studied. For Michelson interferometers, the time-frequency analysis of signals by Short-Time Fourier Transform (STFT) is compared to a time-frequency analysis by Continuous Wavelet Transform (CWT). The results have shown that the CWT was more suitable than the STFT for signals with low signal-to-noise, and low velocity and high acceleration areas. For Mach- Zehnder interferometers, the measurement is carried out by analyzing the phase shift between three interferometric signals (Triature processing). These three methods of digital signal processing were evaluated, their measurement uncertainties estimated, and their restrictions or operational limitations specified from experimental results performed on a pulsed power machine. (authors)

  20. Is digital photography an accurate and precise method for measuring range of motion of the shoulder and elbow?

    Science.gov (United States)

    Russo, Russell R; Burn, Matthew B; Ismaily, Sabir K; Gerrie, Brayden J; Han, Shuyang; Alexander, Jerry; Lenherr, Christopher; Noble, Philip C; Harris, Joshua D; McCulloch, Patrick C

    2018-03-01

    Accurate measurements of shoulder and elbow motion are required for the management of musculoskeletal pathology. The purpose of this investigation was to compare three techniques for measuring motion. The authors hypothesized that digital photography would be equivalent in accuracy and show higher precision compared to the other two techniques. Using infrared motion capture analysis as the reference standard, shoulder flexion/abduction/internal rotation/external rotation and elbow flexion/extension were measured using visual estimation, goniometry, and digital photography on 10 fresh frozen cadavers. These measurements were performed by three physical therapists and three orthopaedic surgeons. Accuracy was defined by the difference from the reference standard (motion capture analysis), while precision was defined by the proportion of measurements within the authors' definition of clinical significance (10° for all motions except for elbow extension where 5° was used). Analysis of variance (ANOVA), t-tests, and chi-squared tests were used. Although statistically significant differences were found in measurement accuracy between the three techniques, none of these differences met the authors' definition of clinical significance. Precision of the measurements was significantly higher for both digital photography (shoulder abduction [93% vs. 74%, p < 0.001], shoulder internal rotation [97% vs. 83%, p = 0.001], and elbow flexion [93% vs. 65%, p < 0.001]) and goniometry (shoulder abduction [92% vs. 74%, p < 0.001] and shoulder internal rotation [94% vs. 83%, p = 0.008]) than visual estimation. Digital photography was more precise than goniometry for measurements of elbow flexion only [93% vs. 76%, p < 0.001]. There was no clinically significant difference in measurement accuracy between the three techniques for shoulder and elbow motion. Digital photography showed higher measurement precision compared to visual estimation for shoulder abduction, shoulder

  1. Light scattering and transmission measurement using digital imaging for online analysis of constituents in milk

    Science.gov (United States)

    Jain, Pranay; Sarma, Sanjay E.

    2015-05-01

    Milk is an emulsion of fat globules and casein micelles dispersed in an aqueous medium with dissolved lactose, whey proteins and minerals. Quantification of constituents in milk is important in various stages of the dairy supply chain for proper process control and quality assurance. In field-level applications, spectrophotometric analysis is an economical option due to the low-cost of silicon photodetectors, sensitive to UV/Vis radiation with wavelengths between 300 - 1100 nm. Both absorption and scattering are witnessed as incident UV/Vis radiation interacts with dissolved and dispersed constituents in milk. These effects can in turn be used to characterize the chemical and physical composition of a milk sample. However, in order to simplify analysis, most existing instrument require dilution of samples to avoid effects of multiple scattering. The sample preparation steps are usually expensive, prone to human errors and unsuitable for field-level and online analysis. This paper introduces a novel digital imaging based method of online spectrophotometric measurements on raw milk without any sample preparation. Multiple LEDs of different emission spectra are used as discrete light sources and a digital CMOS camera is used as an image sensor. The extinction characteristic of samples is derived from captured images. The dependence of multiple scattering on power of incident radiation is exploited to quantify scattering. The method has been validated with experiments for response with varying fat concentrations and fat globule sizes. Despite of the presence of multiple scattering, the method is able to unequivocally quantify extinction of incident radiation and relate it to the fat concentrations and globule sizes of samples.

  2. Validation of a method for measuring the volumetric breast density from digital mammograms

    International Nuclear Information System (INIS)

    Alonzo-Proulx, O; Shen, S Z; Yaffe, M J; Packard, N; Boone, J M; Al-Mayah, A; Brock, K K

    2010-01-01

    The purpose of this study was to evaluate the performance of an algorithm used to measure the volumetric breast density (VBD) from digital mammograms. The algorithm is based on the calibration of the detector signal versus the thickness and composition of breast-equivalent phantoms. The baseline error in the density from the algorithm was found to be 1.25 ± 2.3% VBD units (PVBD) when tested against a set of calibration phantoms, of thicknesses 3-8 cm, with compositions equivalent to fibroglandular content (breast density) between 0% and 100% and under x-ray beams between 26 kVp and 32 kVp with a Rh/Rh anode/filter. The algorithm was also tested against images from a dedicated breast computed tomography (CT) scanner acquired on 26 volunteers. The CT images were segmented into regions representing adipose, fibroglandular and skin tissues, and then deformed using a finite-element algorithm to simulate the effects of compression in mammography. The mean volume, VBD and thickness of the compressed breast for these deformed images were respectively 558 cm 3 , 23.6% and 62 mm. The displaced CT images were then used to generate simulated digital mammograms, considering the effects of the polychromatic x-ray spectrum, the primary and scattered energy transmitted through the breast, the anti-scatter grid and the detector efficiency. The simulated mammograms were analyzed with the VBD algorithm and compared with the deformed CT volumes. With the Rh/Rh anode filter, the root mean square difference between the VBD from CT and from the algorithm was 2.6 PVBD, and a linear regression between the two gave a slope of 0.992 with an intercept of -1.4 PVBD and a correlation with R 2 = 0.963. The results with the Mo/Mo and Mo/Rh anode/filter were similar.

  3. Validation of a method for measuring the volumetric breast density from digital mammograms

    Energy Technology Data Exchange (ETDEWEB)

    Alonzo-Proulx, O; Shen, S Z; Yaffe, M J [Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario M4N 3M5 (Canada); Packard, N; Boone, J M [UC Davis Medical Center, University of California-Davis, Sacramento, CA 95817 (United States); Al-Mayah, A; Brock, K K, E-mail: oliviera@sri.utoronto.c [University Health Network, University of Toronto, Toronto, Ontario M5G 2M9 (Canada)

    2010-06-07

    The purpose of this study was to evaluate the performance of an algorithm used to measure the volumetric breast density (VBD) from digital mammograms. The algorithm is based on the calibration of the detector signal versus the thickness and composition of breast-equivalent phantoms. The baseline error in the density from the algorithm was found to be 1.25 {+-} 2.3% VBD units (PVBD) when tested against a set of calibration phantoms, of thicknesses 3-8 cm, with compositions equivalent to fibroglandular content (breast density) between 0% and 100% and under x-ray beams between 26 kVp and 32 kVp with a Rh/Rh anode/filter. The algorithm was also tested against images from a dedicated breast computed tomography (CT) scanner acquired on 26 volunteers. The CT images were segmented into regions representing adipose, fibroglandular and skin tissues, and then deformed using a finite-element algorithm to simulate the effects of compression in mammography. The mean volume, VBD and thickness of the compressed breast for these deformed images were respectively 558 cm{sup 3}, 23.6% and 62 mm. The displaced CT images were then used to generate simulated digital mammograms, considering the effects of the polychromatic x-ray spectrum, the primary and scattered energy transmitted through the breast, the anti-scatter grid and the detector efficiency. The simulated mammograms were analyzed with the VBD algorithm and compared with the deformed CT volumes. With the Rh/Rh anode filter, the root mean square difference between the VBD from CT and from the algorithm was 2.6 PVBD, and a linear regression between the two gave a slope of 0.992 with an intercept of -1.4 PVBD and a correlation with R{sup 2} = 0.963. The results with the Mo/Mo and Mo/Rh anode/filter were similar.

  4. 3D measurements of live cells via digital holographic microscopy and terahertz spectroscopy

    Science.gov (United States)

    Park, Jun Yong; Oser, Dorian; Iapozzuto, Peter; Norbury, Sean; Mahajan, Supriya; Khmaladze, Alexander; Sharikova, Anna

    2016-03-01

    This is a study of the central nervous system (CNS) cells, including brain micro vascular endothelial cells (BMV) that constitute the blood brain barrier, and C6 glial cells that are the predominant cell in the brain. The cells are exposed to various chemicals by non-invasive, label-free methods. Digital holographic microscopy (DHM) is a technique that records an interference pattern between an object and reference waves, so that the computationally reconstructed holographic image contains both amplitude and phase information, and 3D images are obtained. The measurement of cell cultures by digital holographic microscopy yields information about cell death mechanisms, since these processes are correlated with individual cell volume. Our in-house DHM combines a visible (red) laser source with a conventional microscope base, and LabVIEW-run data processing. Terahertz spectral signatures are associated with structural changes in molecules and provide complementary information about cells. Both CNS cells BMV and C6 cells are treated with the drug "Methamphetamine" (METH), which induces apoptosis in neuronal cells and exhibits decrease in cell volume, a characteristic of cells undergoing apoptosis (induced cell death). METH can cause CNS cell death by cross-talk between mitochondria-, endoplasmic reticulum-, and receptor-mediated apoptotic events, all of which results in drug induced changes in neuroplasticity and significant neuropathology. Doxorubicin (DOX), a popular anticancer drug, is used as a control. We observe that METH treatment resulted in more pronounced cell volume shrinkage in both the BMV and C6 cells, as compared to DOX-induced cell apoptosis.

  5. Fatal bilateral dioctophymatosis.

    Science.gov (United States)

    Li, Gang; Liu, Caigang; Li, Fang; Zhou, Maoyi; Liu, Xiangyong; Niu, Yuanjie

    2010-12-01

    Dioctophyma renale is a parasite that frequently occurs in animals but rarely in humans. The present report describes the clinical observations of a D. renale infection in a 51-yr-old woman. Its clinical signs and diagnostic findings were unspecific until giant worms were observed in the urine and histological findings confirmed it was a D. renale infection. She refused treatment and died of bilateral renal function failure. This is the first confirmed report to follow the natural progression of D. renale infection in a human. Here, we discuss a conservative therapeutic approach and features associated with this parasitic infection.

  6. Recurrent Bilateral Focal Myositis.

    Science.gov (United States)

    Nagafuchi, Hiroko; Nakano, Hiromasa; Ooka, Seido; Takakuwa, Yukiko; Yamada, Hidehiro; Tadokoro, Mamoru; Shimojo, Sadatomo; Ozaki, Shoichi

    This report describes a rare case of recurrent bilateral focal myositis and its successful treatment via methotrexate. A 38-year-old man presented myalgia of the right gastrocnemius in May 2005. Magnetic resonance imaging showed very high signal intensity in the right gastrocnemius on short-tau inversion recovery images. A muscle biopsy revealed inflammatory CD4+ cell-dominant myogenic change. Focal myositis was diagnosed. The first steroid treatment was effective. Tapering of prednisolone, however, repeatedly induced myositis relapse, which progressed to multiple muscle lesions of both lower limbs. Initiation of methotrexate finally allowed successful tapering of prednisolone, with no relapse in the past 4 years.

  7. A digital method for period measurements in a nuclear reactor; Um metodo digital para medidas de periodo em um reator nuclear

    Energy Technology Data Exchange (ETDEWEB)

    Mundim, Sergio Gorretta

    1971-02-15

    The present paper begins by giving a theoretical treatment for the nuclear reactor period. The conventional method of measuring the period is analysed and some previously developed digital methods are described. The paper criticises the latter, pointing out some deficiencies which the proposed process is able to eliminate. All errors connected with this process are also analysed. The paper presents suitable solutions to reduce them to a minimum. The total error is found to he less than the error presented by the other methods described. A digital period meter is designed with memory resources and an automatic scaler changer. Integrated circuits specifications are used in it. Real time experiments with nuclear reactors were made in order to check te validity of the method. The data acquired were applied to a simulated digital period meter implemented in a general purpose computer. The nuclear part of the work was developed at the 'Comissao Nacional de Energia Nuclear' and the simulation work was dane at the 'Departamento de Calculo Cientifico' of COPPE, which also advised the author in the completion of this thesis. (author)

  8. A digital method for period measurements in a nuclear reactor; Um metodo digital para medidas de periodo em um reator nuclear

    Energy Technology Data Exchange (ETDEWEB)

    Mundim, Sergio Gorretta

    1971-02-15

    The present paper begins by giving a theoretical treatment for the nuclear reactor period. The conventional method of measuring the period is analysed and some previously developed digital methods are described. The paper criticises the latter, pointing out some deficiencies which the proposed process is able to eliminate. All errors connected with this process are also analysed. The paper presents suitable solutions to reduce them to a minimum. The total error is found to he less than the error presented by the other methods described. A digital period meter is designed with memory resources and an automatic scaler changer. Integrated circuits specifications are used in it. Real time experiments with nuclear reactors were made in order to check te validity of the method. The data acquired were applied to a simulated digital period meter implemented in a general purpose computer. The nuclear part of the work was developed at the 'Comissao Nacional de Energia Nuclear' and the simulation work was dane at the 'Departamento de Calculo Cientifico' of COPPE, which also advised the author in the completion of this thesis. (author)

  9. Measuring the Bed Load velocity in Laboratory flumes using ADCP and Digital Cameras

    Science.gov (United States)

    Conevski, Slaven; Guerrero, Massimo; Rennie, Colin; Bombardier, Josselin

    2017-04-01

    Measuring the transport rate and apparent velocity of the bedload is notoriously hard and there is not a certain technique that would obtain continues data. There are many empirical models, based on the estimation of the shear stress, but only few involve direct measurement of the bed load velocity. The bottom tracking (BT) mode of an acoustic Doppler current profiler (ADCP) has been used many times to estimate the apparent velocity of the bed load. Herein is the basic idea, to exploit the bias of the BT signal towards the bed load movement and to calibrate this signal with traditional measuring techniques. These measurements are quite scarce and seldom reliable since there are not taken in controlled conditions. So far, no clear confirmation has been conducted in laboratory-controlled conditions that would attest the assumptions made in the estimation of the apparent bed load velocity, nor in the calibration of the empirical equations. Therefore, this study explores several experiments under stationary conditions, where the signal of the ADCP BT mode is recorded and compared to the bed load motion recorded by digital camera videography. The experiments have been performed in the hydraulic laboratories of Ottawa and Bologna, using two different ADCPs and two different high resolution cameras. In total, more then 30 experiments were performed for different sediment mixtures and different hydraulic conditions. In general, a good match is documented between the apparent bed load velocity measured by the ADCP and the videography. The slight deviation in single experiments can be explained by gravel particles inhomogeneity, difficult in reproducing the same hydro-sedimentological conditions and the randomness of the backscattering strength.

  10. Simulation and Measurement of the Transmission Distortions of the Digital Television DVB-T/H Part 2: Hierarchical Modulation Performance

    Directory of Open Access Journals (Sweden)

    R. Stukavec

    2010-09-01

    Full Text Available The paper deals with the second part of results of the Czech Science Foundation research project that was aimed into the simulation and measurement of the transmission distortions of the digital terrestrial television according to DVB-T/H standards. In this part the hierarchical modulation performance characteristics and its simulation and laboratory measurements are presented. The paper deals with the hierarchical oriented COFDM modulator for the digital terrestrial television transmission and DVB-T/H standards and possible utilization of this technique in real broadcasting scenarios – fixed, portable and mobile digital TV, all in one TV channel. Impact of the hierarchical modulation on Modulation Error Rate from I/Q constellations and Bit Error Rates before and after Viterbi decoding in DVB-T/H signal decoding are evaluated and discussed.

  11. A Novel Sub-pixel Measurement Algorithm Based on Mixed the Fractal and Digital Speckle Correlation in Frequency Domain

    Directory of Open Access Journals (Sweden)

    Zhangfang Hu

    2014-10-01

    Full Text Available The digital speckle correlation is a non-contact in-plane displacement measurement method based on machine vision. Motivated by the facts that the low accuracy and large amount of calculation produced by the traditional digital speckle correlation method in spatial domain, we introduce a sub-pixel displacement measurement algorithm which employs a fast interpolation method based on fractal theory and digital speckle correlation in frequency domain. This algorithm can overcome either the blocking effect or the blurring caused by the traditional interpolation methods, and the frequency domain processing also avoids the repeated searching in the correlation recognition of the spatial domain, thus the operation quantity is largely reduced and the information extracting speed is improved. The comparative experiment is given to verify that the proposed algorithm in this paper is effective.

  12. A New Method to Measure Crack Extension in Nuclear Graphite Based on Digital Image Correlation

    Directory of Open Access Journals (Sweden)

    Shigang Lai

    2017-01-01

    Full Text Available Graphite components, used as moderators, reflectors, and core-support structures in a High-Temperature Gas-Cooled Reactor, play an important role in the safety of the reactor. Specifically, they provide channels for the fuel elements, control rods, and coolant flow. Fracture is the main failure mode for graphite, and breaching of the above channels by crack extension will seriously threaten the safety of a reactor. In this paper, a new method based on digital image correlation (DIC is introduced for measuring crack extension in brittle materials. Cross-correlation of the displacements measured by DIC with a step function was employed to identify the advancing crack tip in a graphite beam specimen under three-point bending. The load-crack extension curve, which is required for analyzing the R-curve and tension softening behaviors, was obtained for this material. Furthermore, a sensitivity analysis of the threshold value employed for the cross-correlation parameter in the crack identification process was conducted. Finally, the results were verified using the finite element method.

  13. Use of higher order signal moments and high speed digital sampling technique for neutron flux measurements

    Science.gov (United States)

    Baers, L. B.; Gutierrez, T. Rivero; Mendoza, R. A. Carrillo; Santana, G. Jimenez

    1993-08-01

    The second (conventional variance or Campbell signal), the third, and the modified fourth order central signal moments associated with the amplified and filtered currents from two electrodes of an ex-core neutron sensitive fission detector were measured versus the reactor power of the 1-MW TRIGA reactor in Mexico City. Two channels of a high-speed (400-MHz) multiplexing data sampler and an analog-to-digital converter with 12-b resolution and 1-Mword buffer memory were used. The data were further retrieved into a PC, and estimates for autocorrelation and cross-correlation moments up to the fifth order, coherence, skewness, excess, etc., quantities were calculated offline. Five-mode operation of the detector was achieved, including conventional counting rates and currents in agreement with theory and the authors' previous results with analog techniques. The signals are proportional to the neutron flux and reactor power in some flux ranges. The suppression of background noise is improved and the lower limit of the measurement range is extended as the order of moment is increased, in agreement with theory.

  14. Measuring Effectiveness in Digital Game-Based Learning: A Methodological Review.

    Directory of Open Access Journals (Sweden)

    Anissa All

    2014-06-01

    Full Text Available In recent years, a growing number of studies are being conducted into the effectiveness of digital game-based learning (DGBL. Despite this growing interest, there is a lack of sound empirical evidence on the effectiveness of DGBL due to different outcome measures for assessing effectiveness, varying methods of data collection and inconclusive or difficult to interpret results. This has resulted in a need for an overarching methodology for assessing the effectiveness of DGBL. The present study took a first step in this direction by mapping current methods used for assessing the effectiveness of DGBL. Results showed that currently, comparison of results across studies and thus looking at effectiveness of DGBL on a more general level is problematic due to diversity in and suboptimal study designs. Variety in study design relates to three issues, namely different activities that are implemented in the control groups, different measures for assessing the effectiveness of DGBL and the use of different statistical techniques for analyzing learning outcomes. Suboptimal study designs are the result of variables confounding study results. Possible confounds that were brought forward in this review are elements that are added to the game as part of the educational intervention (e.g., required reading, debriefing session, instructor influences and practice effects when using the same test pre- and post-intervention. Lastly, incomplete information on the study design impedes replication of studies and thus falsification of study results.

  15. Bilateral acoustic neuromas.

    Science.gov (United States)

    Anand, V T; Byrnes, D P; Walby, A P; Kerr, A G

    1993-10-01

    This article reviews 12 patients with bilateral acoustic neuromas. The sex incidence was equal and the mean age at diagnosis was 26.2 years. The family history was positive in nine of the patients. Five patients have had incomplete surgical removal of acoustic neuromas on both sides. Two of them are completely deaf and the other three have severe sensorineural hearing loss in one ear and no hearing in the other ear. In five patients the tumour on one side has been operated on and the other side is being observed with at least short-term preservation of good hearing. The remaining two patients died of intra-cranial complications, one of them post-operatively. Four patients developed facial palsy immediately following surgery and one developed facial weakness 6 months after surgery. Guidelines are discussed for the care of these patients including the timing of surgery and alternative treatment options (observation, radio-surgery and chemotherapy). This is essentially a group of young individuals who have had multiple operations for bilateral acoustic tumours and associated manifestations and for whom the disease and the sequelae of treatment can be tragic.

  16. Bilateral and unilateral ECT: effects on verbal and nonverbal memory.

    Science.gov (United States)

    Squire, S R; Slater, P C

    1978-11-01

    The memory loss associated with bilateral and nondominant unilateral ECT was assessed with verbal memory tests known to be sensitive to left temporal lobe dysfunction and with nonverbal memory tests known to be sensitive to right temporal lobe dysfunction. Bilateral ECT markedly impaired delayed retention of verbal and nonverbal material. Right unilateral ECT impaired delayed retention of nonverbal material without measurably affecting retention of verbal material. Nonverbal memory was affected less by right unilateral ECT than by bilateral ECT. These findings, taken together with a consideration of the clinical efficacy of the two types of treatment, make what appears to be a conclusive case for unilateral over bilateral ECT.

  17. Internal displacement and strain measurement using digital volume correlation: a least-squares framework

    International Nuclear Information System (INIS)

    Pan, Bing; Wu, Dafang; Wang, Zhaoyang

    2012-01-01

    As a novel tool for quantitative 3D internal deformation measurement throughout the interior of a material or tissue, digital volume correlation (DVC) has increasingly gained attention and application in the fields of experimental mechanics, material research and biomedical engineering. However, the practical implementation of DVC involves important challenges such as implementation complexity, calculation accuracy and computational efficiency. In this paper, a least-squares framework is presented for 3D internal displacement and strain field measurement using DVC. The proposed DVC combines a practical linear-intensity-change model with an easy-to-implement iterative least-squares (ILS) algorithm to retrieve 3D internal displacement vector field with sub-voxel accuracy. Because the linear-intensity-change model is capable of accounting for both the possible intensity changes and the relative geometric transform of the target subvolume, the presented DVC thus provides the highest sub-voxel registration accuracy and widest applicability. Furthermore, as the ILS algorithm uses only first-order spatial derivatives of the deformed volumetric image, the developed DVC thus significantly reduces computational complexity. To further extract 3D strain distributions from the 3D discrete displacement vectors obtained by the ILS algorithm, the presented DVC employs a pointwise least-squares algorithm to estimate the strain components for each measurement point. Computer-simulated volume images with controlled displacements are employed to investigate the performance of the proposed DVC method in terms of mean bias error and standard deviation error. Results reveal that the present technique is capable of providing accurate measurements in an easy-to-implement manner, and can be applied to practical 3D internal displacement and strain calculation. (paper)

  18. Defining, Designing for, and Measuring "Social Constructivist Digital Literacy" Development in Learners: A Proposed Framework

    Science.gov (United States)

    Reynolds, Rebecca

    2016-01-01

    This paper offers a newly conceptualized modular framework for digital literacy that defines this concept as a task-driven "social constructivist digital literacy," comprising 6 practice domains grounded in Constructionism and social constructivism: Create, Manage, Publish, Socialize, Research, Surf. The framework articulates possible…

  19. Rapid 3D measurement of human faces for biometric application by digital fringe projection with digital light projection (DLP®)

    Science.gov (United States)

    Benderoth, Christian; Bell, Rebecca L.; Frankowski, Gottfried

    2008-04-01

    Facial recognitions of people can be used for the identification of individuals, or can serve as verification e.g. for access controls. The process requires, that the facial data is captured and then compared with stored reference data. In this context, far better recognition performances can be expected from 3-dimensional facial recognition systems than can be from the 2-dimensional systems which are currently used. The accuracy with which the facial profile can be captured, depends on the speed off the measuring data acquisition i.e. the scanning speed and on the measuring accuracy of the measuring device i.e. the 3D scanner.

  20. Improvements on digital inline holographic PTV for 3D wall-bounded turbulent flow measurements

    International Nuclear Information System (INIS)

    Toloui, Mostafa; Mallery, Kevin; Hong, Jiarong

    2017-01-01

    Three-dimensional (3D) particle image velocimetry (PIV) and particle tracking velocimetry (PTV) provide the most comprehensive flow information for unraveling the physical phenomena in a wide range of fluid problems, from microfluidics to wall-bounded turbulent flows. Compared with other 3D PIV techniques, such as tomographic PIV and defocusing PIV, the digital inline holographic PTV (DIH-PTV) provides 3D flow measurement solution with high spatial resolution, low cost optical setup, and easy alignment and calibration. Despite these advantages, DIH-PTV suffers from major limitations including poor longitudinal resolution, human intervention (i.e. requirement for manually determined tuning parameters during tracer field reconstruction and extraction), limited tracer concentration, small sampling volume and expensive computations, limiting its broad use for 3D flow measurements. In this study, we present our latest developments on minimizing these challenges, which enables high-fidelity DIH-PTV implementation to larger sampling volumes with significantly higher particle seeding densities suitable for wall-bounded turbulent flow measurements. The improvements include: (1) adjustable window thresholding; (2) multi-pass 3D tracking; (3) automatic wall localization; and (4) continuity-based out-of-plane velocity component computation. The accuracy of the proposed DIH-PTV method is validated with conventional 2D PIV and double-view holographic PTV measurements in smooth-wall turbulent channel flow experiments. The capability of the technique in characterization of wall-bounded turbulence is further demonstrated through its application to flow measurements for smooth- and rough-wall turbulent channel flows. In these experiments, 3D velocity fields are measured within sampling volumes of 14.7  ×  50.0  ×  14.4 mm 3 (covering the entire depth of the channel) with a velocity resolution of  <1.1 mm/vector. Overall, the presented DIH-PTV method and

  1. Prognosis of synchronous bilateral breast cancer

    DEFF Research Database (Denmark)

    Holm, Marianne; Tjønneland, Anne; Balslev, Eva

    2014-01-01

    Currently, no consistent evidence-based guidelines for the management of synchronous bilateral breast cancer (SBBC) exist and it is uncertain how presenting with SBBC affects patients' prognosis. We conducted a review of studies analyzing the association between SBBC and prognosis. The studies...... that reported adjusted effect measures were included in meta-analyses of effect of bilaterality on breast cancer mortality. From 57 initially identified records 17 studies from 11 different countries including 8,050 SBBC patients were included. The quality of the studies varied but was generally low with small...... sample sizes, and lack of consistent, detailed histo-pathological information. When doing meta-analysis on the subgroup of studies that provided adjusted effect estimates on breast cancer mortality (nine studies including 3,631 SBBC cases), we found that bilaterality in itself had a negative impact...

  2. Bilateral breast carcinoma: results with breast conservation therapy and a comparison with bilateral mastectomy

    International Nuclear Information System (INIS)

    Kim, David H.; Haffty, Bruce G.

    1996-01-01

    between the BCT, UCT, and BMAST groups with respect to age, histology, clinical stage, primary tumor size, axillary nodal status, or adjuvant systemic therapy. As noted below, there were no statistically significant differences between the three study groups with respect to overall survival, disease-free survival, distant metastasis-free survival, or local regional relapse-free survival. It is noteworthy that there was no significant difference between the local breast relapse rate and the chest wall relapse rate when comparing the conservatively treated group and the bilateral mastectomy group. Conclusions: Patients with bilateral breast carcinoma presenting either synchronously or metachronously are suitable candidates for bilateral conservative treatment. Outcome of these patients with respect to all measurable endpoints did not significantly differ from patients treated conservatively for unilateral breast cancer, or for their counterparts with bilateral disease of similar stage treated with bilateral mastectomy. Of particular note, the 10-year local regional relapse-free rate of patients undergoing bilateral mastectomy did not differ significantly from the local regional relapse rate of those patients treated with bilateral conservative treatment

  3. Full 3D internal strain measurement for device packaging materials using synchrotron laminography and volumetric digital image correlation method

    International Nuclear Information System (INIS)

    Asada, Takashi; Kimura, Hidehiko; Yamaguchi, Satoshi; Kano, Taiki; Kajiwara, Kentaro

    2014-01-01

    In order to measure full 3D internal strain field of resin molding compound specimens, synchrotron computed tomography and laminography at SPring-8 were performed. Then the reconstructed images were applied to 3D digital image correlation method to compute internal strain field. The results showed that internal strains in resin molding compound could be visualized in this way. (author)

  4. Light-reflection random-target method for measurement of the modulation transfer function of a digital video-camera

    Czech Academy of Sciences Publication Activity Database

    Pospíšil, Jaroslav; Jakubík, P.; Machala, L.

    2005-01-01

    Roč. 116, - (2005), s. 573-585 ISSN 0030-4026 Institutional research plan: CEZ:AV0Z10100522 Keywords : random-target measuring method * light-reflection white - noise target * digital video camera * modulation transfer function * power spectral density Subject RIV: BH - Optics, Masers, Lasers Impact factor: 0.395, year: 2005

  5. A kinematic measurement for ductile and brittle failure of materials using digital image correlation

    Directory of Open Access Journals (Sweden)

    M.M. Reza Mousavi

    2016-12-01

    Full Text Available This paper addresses some material level test which is done on quasi-brittle and ductile materials in the laboratory. The displacement control experimental program is composed of mortar cylinders under uniaxial compression shows quasi-brittle behavior and seemingly round-section aluminum specimens under uniaxial tension represents ductile behavior. Digital Image Correlation gives full field measurement of deformation in both aluminum and mortar specimens. Likewise, calculating the relative displacement of two points located on top and bottom of virtual LVDT, which is virtually placed on the surface of the specimen, gives us the classical measure of strain. However, the deformation distribution is not uniform all over the domain of specimens mainly due to imperfect nature of experiments and measurement devices. Displacement jumps in the fracture zone of mortar specimens and strain localization in the necking area for the aluminum specimen, which are reflecting different deformation values and deformation gradients, is compared to the other regions. Since the results are inherently scattered, it is usually non-trivial to smear out the stress of material as a function of a single strain value. To overcome this uncertainty, statistical analysis could bring a meaningful way to closely look at scattered results. A large number of virtual LVDTs are placed on the surface of specimens in order to collect statistical parameters of deformation and strain. Values of mean strain, standard deviation and coeffcient of variations for each material are calculated and correlated with the failure type of the corresponding material (either brittle or ductile. The main limiters for standard deviation and coeffcient of variations for brittle and ductile failure, in pre-peak and post-peak behavior are established and presented in this paper. These limiters help us determine whether failure is brittle or ductile without determining of stress level in the material.

  6. Improved non-invasive method for aerosol particle charge measurement employing in-line digital holography

    Science.gov (United States)

    Tripathi, Anjan Kumar

    Electrically charged particles are found in a wide range of applications ranging from electrostatic powder coating, mineral processing, and powder handling to rain-producing cloud formation in atmospheric turbulent flows. In turbulent flows, particle dynamics is influenced by the electric force due to particle charge generation. Quantifying particle charges in such systems will help in better predicting and controlling particle clustering, relative motion, collision, and growth. However, there is a lack of noninvasive techniques to measure particle charges. Recently, a non-invasive method for particle charge measurement using in-line Digital Holographic Particle Tracking Velocimetry (DHPTV) technique was developed in our lab, where charged particles to be measured were introduced to a uniform electric field, and their movement towards the oppositely charged electrode was deemed proportional to the amount of charge on the particles (Fan Yang, 2014 [1]). However, inherent speckle noise associated with reconstructed images was not adequately removed and therefore particle tracking data was contaminated. Furthermore, particle charge calculation based on particle deflection velocity neglected the particle drag force and rebound effect of the highly charged particles from the electrodes. We improved upon the existing particle charge measurement method by: 1) hologram post processing, 2) taking drag force into account in charge calculation, 3) considering rebound effect. The improved method was first fine-tuned through a calibration experiment. The complete method was then applied to two different experiments, namely conduction charging and enclosed fan-driven turbulence chamber, to measure particle charges. In all three experiments conducted, the particle charge was found to obey non-central t-location scale family of distribution. It was also noted that the charge distribution was insensitive to the change in voltage applied between the electrodes. The range of voltage

  7. Bilateral tubercular mastitis

    Directory of Open Access Journals (Sweden)

    Kant Surya

    2007-01-01

    Full Text Available Breast tuberculosis is a rare form of tuberculosis. Moreover the disease is often overlooked and misdiagnosed as carcinoma or pyogenic abscess. Reports on breast tuberculosis from India have been few; reported incidence of breast tuberculosis amongst the total number of mammary conditions varies between 0.64 and 3.59 per cent. Bilateral involvement is still more uncommon (3%. Most accepted view for spread of infection is centripetal lymphatic spread as axillary node involvement was shown to occur in 50 to 75 per cent of cases of tubercular mastitis. Here we re-port a case of a young female who presented with draining sinuses in the breast and no axillary lymphadenopathy. Fine needle aspiration cytology (FNAC of breast lump showed evidence of granulomatous mastitis. She was given therapeutic trial of four drug antitubercular treatment. Both the lump disappeared and sinus healed after six months of antitubercular treatment. Thus a retrospective diagnosis of tu-bercular mastitis was made.

  8. Bilateral triple renal arteries

    International Nuclear Information System (INIS)

    Pestemalci, Turan; Yildiz, Yusuf Zeki; Yildirim, Mehmet; Mavi, Ayfer; Gumusburun, Erdem

    2009-01-01

    Knowledge of the variations of the renal artery has grown in importance with increasing numbers of renal transplants, vascular reconstructions and various surgical and radio logic techniques being performed in recent years. We report the presence of bilateral triple renal arteries, discovered on routine dissection of a male cadaver. On the right side, one additional renal artery originated from the abdominal aorta (distributed to superior pole of the kidney) and one other originated from the right common iliac artery (distributed to lower pole of the kidney). On the left side, both additional renal arteries originated from the abdominal aorta. Our observation has been compared with variations described in the literature and their clinical importance has been emphasized. (author)

  9. Idiopathic Bilateral Bloody Tearing

    Directory of Open Access Journals (Sweden)

    Emrullah Beyazyıldız

    2015-01-01

    Full Text Available Bloody tear is a rare and distinct clinic phenomenon. We report a case presenting with the complaint of recurrent episodes of bilateral bloody tearing. A 16-year-old girl presented to our clinic with complaint of bloody tearing in both eyes for 3 months. Bloody tearing was not associated with her menses. A blood-stained discharge from the punctum was not observed during the compression of both nasolacrimal ducts. Nasolacrimal passage was not obstructed. Imaging studies such as dacryocystography and gradient-echo magnetic resonance imaging (MRI of nasolacrimal canal were normal. Intranasal endoscopic evaluation was normal. We collected samples from bloody tears two times and pathological examination was performed. Pathological analysis showed lots of squamous cells and no endometrial cells; dysplastic cells were found. Further evaluations for underlying causes were unremarkable. No abnormalities were found in ophthalmologic, radiologic, and pathologic investigations. This condition is likely a rare abnormality and the least recognized aetiology for the idiopathic phenomenon.

  10. Bilateral Antepartum Mastitis

    Directory of Open Access Journals (Sweden)

    Peyman Alibeigi

    2010-12-01

    Full Text Available Antepartum mastitis is a rare condition, whereas postpartum orlactation mastitis is a common problem. This report introducesa case of complicated bilateral antepartum mastitis, which wastreated successfully by drain insertion and antibiotic therapy.The patient was a 23-year-old woman in the 23rd week of herfirst pregnancy. Her chief complaint was progressive swelling,redness and radicular pain in both breasts, which had beenstarted gradually from the 18th week of pregnancy. The patientwas admitted to hospital, and received oral and intravenous antibioticsempirically, which was not effective. The patient wastreated by drainage and oral antibiotic therapy. Based on theapproaches employed and the outcomes achieved it is suggestedthat early surgical insertion in the presence of fluid collection inantepartum mastitis will shorten hospitalization and course ofintravenous antibiotic therapy.Iran J Med Sci 2010; 35(4: 327-330.

  11. Measurement of spatial refractive index distributions of fusion spliced optical fibers by digital holographic microtomography

    Science.gov (United States)

    Pan, Feng; Deng, Yating; Ma, Xichao; Xiao, Wen

    2017-11-01

    Digital holographic microtomography is improved and applied to the measurements of three-dimensional refractive index distributions of fusion spliced optical fibers. Tomographic images are reconstructed from full-angle phase projection images obtained with a setup-rotation approach, in which the laser source, the optical system and the image sensor are arranged on an optical breadboard and synchronously rotated around the fixed object. For retrieving high-quality tomographic images, a numerical method is proposed to compensate the unwanted movements of the object in the lateral, axial and vertical directions during rotation. The compensation is implemented on the two-dimensional phase images instead of the sinogram. The experimental results exhibit distinctly the internal structures of fusion splices between a single-mode fiber and other fibers, including a multi-mode fiber, a panda polarization maintaining fiber, a bow-tie polarization maintaining fiber and a photonic crystal fiber. In particular, the internal structure distortion in the fusion areas can be intuitively observed, such as the expansion of the stress zones of polarization maintaining fibers, the collapse of the air holes of photonic crystal fibers, etc.

  12. Analysis of chemiluminescence measurements by grey-scale ICCD and colour digital cameras

    International Nuclear Information System (INIS)

    Migliorini, F; Maffi, S; De Iuliis, S; Zizak, G

    2014-01-01

    Spectral, grey-scale and colour chemiluminescence measurements of C 2 * and CH* radicals' emission are carried out on the flame front of a methane–air premixed flame at different equivalence ratios. To this purpose, properly spatially resolved optical equipment has been implemented in order to reduce the background emission from other burned gas regions. The grey-scale (ICCD + interference filters) and RGB colour (commercial digital camera) approaches have been compared in order to find a correspondence between the C 2 * and the green component, as well as the CH* and the blue component of the emission intensities. The C 2 */CH* chemiluminescence ratio has been investigated at different equivalence ratios and a good correlation has been obtained, showing the possibility of sensing the equivalence ratio in practical systems. The grey-scale and colour chemiluminescence analysis has then been applied to a meso-scale not premixed swirl combustor fuelled with a methane–air mixture and operating at 0.3 MPa. 2D results are presented and discussed in this work. (paper)

  13. A mass spectrometric study of K39/K41 abundance variations by dual collection and digital measurement technique

    International Nuclear Information System (INIS)

    Bhattacharjee, P.K.; Venkatasubramanian, V.S.

    1977-01-01

    The status of K 39 /K 41 abundance ratios in rocks and minerals is reviewed and the errors and corrections required in such measurements pointed out. A double-collector mass spectrometer with digital recording has been used for K 39 /K 41 measurements in a number of granites, charnockites and zeolites. While the granites do not reveal fractionation effect, K 39 deficiency has been observed in charnockites and zeolites. Possible reasons for such a fractionation are pointed out. (author)

  14. New Stereo Vision Digital Camera System for Simultaneous Measurement of Cloud Base Height and Atmospheric Visibility

    Science.gov (United States)

    Janeiro, F. M.; Carretas, F.; Palma, N.; Ramos, P. M.; Wagner, F.

    2013-12-01

    Clouds play an important role in many aspects of everyday life. They affect both the local weather as well as the global climate and are an important parameter on climate change studies. Cloud parameters are also important for weather prediction models which make use of actual measurements. It is thus important to have low-cost instrumentation that can be deployed in the field to measure those parameters. This kind of instruments should also be automated and robust since they may be deployed in remote places and be subject to adverse weather conditions. Although clouds are very important in environmental systems, they are also an essential component of airplane safety when visual flight rules (VFR) are enforced, such as in most small aerodromes where it is not economically viable to install instruments for assisted flying. Under VFR there are strict limits on the height of the cloud base, cloud cover and atmospheric visibility that ensure the safety of the pilots and planes. Although there are instruments, available in the market, to measure those parameters, their relatively high cost makes them unavailable in many local aerodromes. In this work we present a new prototype which has been recently developed and deployed in a local aerodrome as proof of concept. It is composed by two digital cameras that capture photographs of the sky and allow the measurement of the cloud height from the parallax effect. The new developments consist on having a new geometry which allows the simultaneous measurement of cloud base height, wind speed at cloud base height and atmospheric visibility, which was not previously possible with only two cameras. The new orientation of the cameras comes at the cost of a more complex geometry to measure the cloud base height. The atmospheric visibility is calculated from the Lambert-Beer law after the measurement of the contrast between a set of dark objects and the background sky. The prototype includes the latest hardware developments that

  15. Accurate measurement of transgene copy number in crop plants using droplet digital PCR.

    Science.gov (United States)

    Collier, Ray; Dasgupta, Kasturi; Xing, Yan-Ping; Hernandez, Bryan Tarape; Shao, Min; Rohozinski, Dominica; Kovak, Emma; Lin, Jeanie; de Oliveira, Maria Luiza P; Stover, Ed; McCue, Kent F; Harmon, Frank G; Blechl, Ann; Thomson, James G; Thilmony, Roger

    2017-06-01

    Genetic transformation is a powerful means for the improvement of crop plants, but requires labor- and resource-intensive methods. An efficient method for identifying single-copy transgene insertion events from a population of independent transgenic lines is desirable. Currently, transgene copy number is estimated by either Southern blot hybridization analyses or quantitative polymerase chain reaction (qPCR) experiments. Southern hybridization is a convincing and reliable method, but it also is expensive, time-consuming and often requires a large amount of genomic DNA and radioactively labeled probes. Alternatively, qPCR requires less DNA and is potentially simpler to perform, but its results can lack the accuracy and precision needed to confidently distinguish between one- and two-copy events in transgenic plants with large genomes. To address this need, we developed a droplet digital PCR-based method for transgene copy number measurement in an array of crops: rice, citrus, potato, maize, tomato and wheat. The method utilizes specific primers to amplify target transgenes, and endogenous reference genes in a single duplexed reaction containing thousands of droplets. Endpoint amplicon production in the droplets is detected and quantified using sequence-specific fluorescently labeled probes. The results demonstrate that this approach can generate confident copy number measurements in independent transgenic lines in these crop species. This method and the compendium of probes and primers will be a useful resource for the plant research community, enabling the simple and accurate determination of transgene copy number in these six important crop species. Published 2017. This article is a U.S. Government work and is in the public domain in the USA.

  16. Evaluating digital libraries in the health sector. Part 2: measuring impacts and outcomes.

    Science.gov (United States)

    Cullen, Rowena

    2004-03-01

    This is the second part of a two-part paper which explores methods that can be used to evaluate digital libraries in the health sector. Part 1 focuses on approaches to evaluation that have been proposed for mainstream digital information services. This paper investigates evaluative models developed for some innovative digital library projects, and some major national and international electronic health information projects. The value of ethnographic methods to provide qualitative data to explore outcomes, adding to quantitative approaches based on inputs and outputs is discussed. The paper concludes that new 'post-positivist' models of evaluation are needed to cover all the dimensions of the digital library in the health sector, and some ways of doing this are outlined.

  17. A novel bilateral lower extremity mirror therapy intervention for individuals with stroke

    Directory of Open Access Journals (Sweden)

    Lucas D. Crosby

    2016-12-01

    Full Text Available Despite improvements made in stroke rehabilitation, motor impairment and gait deficits persist at discharge. New interventions are needed. Mirror therapy has promise as one element of a rehabilitation program. The primary objectives were to 1 describe a bilateral, lower extremity mirror therapy (LE-MT device and training protocol and 2 investigate the feasibility of LE-MT. A LE-MT device was constructed to train bilateral LE movements for 30 min, 3 times/week for 4 weeks, as an adjunct to physiotherapy in three individuals post-stroke. Sessions were digitally recorded and reviewed to extract feasibility measures; repetitions, rests and session duration. Pre and post measures of gait and motor impairment were taken. Two participants completed 100% of the sessions and a third completed 83% due to a recurrence of pre-existing back pain. Repetitions increased and session duration was maintained. Number of rests decreased for two participants and increased for one participant. Participants reported fatigue and mild muscle soreness but also that the intervention was tolerable. Positive gait changes included increased velocity and decreased variability. LE motor impairment also improved. A bilateral LE-MT adjunct intervention for stroke is feasible and may have positive effects. A history of low back pain should be a precaution.

  18. A digital, constant-frequency pulsed phase-locked-loop instrument for real-time, absolute ultrasonic phase measurements

    Science.gov (United States)

    Haldren, H. A.; Perey, D. F.; Yost, W. T.; Cramer, K. E.; Gupta, M. C.

    2018-05-01

    A digitally controlled instrument for conducting single-frequency and swept-frequency ultrasonic phase measurements has been developed based on a constant-frequency pulsed phase-locked-loop (CFPPLL) design. This instrument uses a pair of direct digital synthesizers to generate an ultrasonically transceived tone-burst and an internal reference wave for phase comparison. Real-time, constant-frequency phase tracking in an interrogated specimen is possible with a resolution of 0.000 38 rad (0.022°), and swept-frequency phase measurements can be obtained. Using phase measurements, an absolute thickness in borosilicate glass is presented to show the instrument's efficacy, and these results are compared to conventional ultrasonic pulse-echo time-of-flight (ToF) measurements. The newly developed instrument predicted the thickness with a mean error of -0.04 μm and a standard deviation of error of 1.35 μm. Additionally, the CFPPLL instrument shows a lower measured phase error in the absence of changing temperature and couplant thickness than high-resolution cross-correlation ToF measurements at a similar signal-to-noise ratio. By showing higher accuracy and precision than conventional pulse-echo ToF measurements and lower phase errors than cross-correlation ToF measurements, the new digitally controlled CFPPLL instrument provides high-resolution absolute ultrasonic velocity or path-length measurements in solids or liquids, as well as tracking of material property changes with high sensitivity. The ability to obtain absolute phase measurements allows for many new applications than possible with previous ultrasonic pulsed phase-locked loop instruments. In addition to improved resolution, swept-frequency phase measurements add useful capability in measuring properties of layered structures, such as bonded joints, or materials which exhibit non-linear frequency-dependent behavior, such as dispersive media.

  19. A boy with bilateral SUNA

    DEFF Research Database (Denmark)

    Vuković Cvetković, Vlasta; Jensen, Rigmor Højland

    2017-01-01

    secondary causes should be searched for vigorously if there are bilateral symptoms. Despite a number of therapeutic trials, effective management for the majority of SUNA patients is not available at present. Management of SUNA is often difficult. Case We report the case of a young boy with bilateral SUNA...

  20. Silicosis with bilateral spontaneous pneumothorax

    Directory of Open Access Journals (Sweden)

    Fotedar Sanjay

    2010-01-01

    Full Text Available Presentation with simultaneous bilateral pneumothorax is uncommon and usually in the context of secondary spontaneous pneumothorax.The association of pneumothorax and silicosis is infrequent and most cases are unilateral. Bilateral pneumothorax in silicosis is very rare with just a few reports in medical literature.

  1. Bilateral persistent hyperplastic primary vitreous

    Directory of Open Access Journals (Sweden)

    Jain Tarun

    2009-01-01

    Full Text Available A case of bilateral persistent hyperplastic primary vitreous (PHPV in a 3-month-old male infant, who had bilateral leukokoria, is presented. The child was referred for imaging with a clinical suspicion of retinoblastoma. Gray-scale ultrasound evaluation revealed an echogenic band in the posterior segment of both globes, extending from the posterior surface of the lens capsule to the optic disc. Doppler examination revealed the presence of arterial flow in the band in both globes. Associated echogenic hemorrhage was also seen, which was confirmed by computed tomography. Most cases of PHPV are sporadic and unilateral, and bilateral PHPV is rare. The imaging features in this case suggest the diagnosis of bilateral PHPV and differentiate it from retinoblastoma. This entity, although infrequent, should be considered in the differential diagnosis while evaluating bilateral leukokoria.

  2. Semi-automated Digital Imaging and Processing System for Measuring Lake Ice Thickness

    Science.gov (United States)

    Singh, Preetpal

    to detect equipment failure and identify defective products at the assembly line. The research work in this thesis combines machine vision and image processing technology to build a digital imaging and processing system for monitoring and measuring lake ice thickness in real time. An ultra-compact USB camera is programmed to acquire and transmit high resolution imagery for processing with MATLAB Image Processing toolbox. The image acquisition and transmission process is fully automated; image analysis is semi-automated and requires limited user input. Potential design changes to the prototype and ideas on fully automating the imaging and processing procedure are presented to conclude this research work.

  3. Measurement of the optical density of packable composites: comparison between direct and indirect digital systems

    Directory of Open Access Journals (Sweden)

    Graziottin Luiz Felipe Rodrigues

    2002-01-01

    Full Text Available The aim of this study was to measure the optical density of four packable composite resins with widths of 1, 2, 3 and 4 mm, by means of Digora® (direct and DentScan DentView® (indirect digital imaging systems, in order to compare both methods. Twenty acrylic plates, with the proposed thicknesses, were used, each one containing a sample of each resin. Each acrylic plate was radiographed three times, under a standardized technique. For the Digora® system, an optical plate was used under each resin sample, and, for the DentScan DentView® system, occlusal films were employed, totalizing 60 exposures for each system. Optical plates and films were scanned and three consecutive optical readouts were carried out, totalizing 1,440 readouts. The results were submitted to statistical analysis and revealed that the average optical density of the four resins always increased as thickness increased. Regarding the comparisons between the composite resins, in both analysis the resin with the greater optical density was SurefilTM followed by ProdigyTM Condensable, AlertTM and Solitaire®. The correlations between the results of Digora® and DentScan DentView® were significant for the different thicknesses and materials. The observed tendency is that as the values obtained with the Digora® system increase, so do the values obtained with DentScan DentView®. While thickness increased, the values of optical density in both Digora® and DentScan DentView® tended to approach each other. The Digora® system presented smaller amplitude between the results obtained in adjacent thicknesses.

  4. Evaluation of the accuracy of linear measurements on multi-slice and cone beam computed tomography scans to detect the mandibular canal during bilateral sagittal split osteotomy of the mandible.

    Science.gov (United States)

    Freire-Maia, B; Machado, V deC; Valerio, C S; Custódio, A L N; Manzi, F R; Junqueira, J L C

    2017-03-01

    The aim of this study was to compare the accuracy of linear measurements of the distance between the mandibular cortical bone and the mandibular canal using 64-detector multi-slice computed tomography (MSCT) and cone beam computed tomography (CBCT). It was sought to evaluate the reliability of these examinations in detecting the mandibular canal for use in bilateral sagittal split osteotomy (BSSO) planning. Eight dry human mandibles were studied. Three sites, corresponding to the lingula, the angle, and the body of the mandible, were selected. After the CT scans had been obtained, the mandibles were sectioned and the bone segments measured to obtain the actual measurements. On analysis, no statistically significant difference was found between the measurements obtained through MSCT and CBCT, or when comparing the measurements from these scans with the actual measurements. It is concluded that the images obtained by CT scan, both 64-detector multi-slice and cone beam, can be used to obtain accurate linear measurements to locate the mandibular canal for preoperative planning of BSSO. The ability to correctly locate the mandibular canal during BSSO will reduce the occurrence of neurosensory disturbances in the postoperative period. Copyright © 2016 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  5. Sample-interpolation timing: an optimized technique for the digital measurement of time of flight for γ rays and neutrons at relatively low sampling rates

    International Nuclear Information System (INIS)

    Aspinall, M D; Joyce, M J; Mackin, R O; Jarrah, Z; Boston, A J; Nolan, P J; Peyton, A J; Hawkes, N P

    2009-01-01

    A unique, digital time pick-off method, known as sample-interpolation timing (SIT) is described. This method demonstrates the possibility of improved timing resolution for the digital measurement of time of flight compared with digital replica-analogue time pick-off methods for signals sampled at relatively low rates. Three analogue timing methods have been replicated in the digital domain (leading-edge, crossover and constant-fraction timing) for pulse data sampled at 8 GSa s −1 . Events arising from the 7 Li(p, n) 7 Be reaction have been detected with an EJ-301 organic liquid scintillator and recorded with a fast digital sampling oscilloscope. Sample-interpolation timing was developed solely for the digital domain and thus performs more efficiently on digital signals compared with analogue time pick-off methods replicated digitally, especially for fast signals that are sampled at rates that current affordable and portable devices can achieve. Sample interpolation can be applied to any analogue timing method replicated digitally and thus also has the potential to exploit the generic capabilities of analogue techniques with the benefits of operating in the digital domain. A threshold in sampling rate with respect to the signal pulse width is observed beyond which further improvements in timing resolution are not attained. This advance is relevant to many applications in which time-of-flight measurement is essential

  6. Digit Ratio (2D:4D) Predicts Self-Reported Measures of General Competitiveness, but Not Behavior in Economic Experiments.

    Science.gov (United States)

    Bönte, Werner; Procher, Vivien D; Urbig, Diemo; Voracek, Martin

    2017-01-01

    The ratio of index finger length to ring finger length (2D:4D) is considered to be a putative biomarker of prenatal androgen exposure (PAE), with previous research suggesting that 2D:4D is associated with human behaviors, especially sex-typical behaviors. This study empirically examines the relationship between 2D:4D and individual competitiveness, a behavioral trait that is found to be sexually dimorphic. We employ two related, but distinct, measures of competitiveness, namely behavioral measures obtained from economic experiments and psychometric self-reported measures. Our analyses are based on two independent data sets obtained from surveys and economic experiments with 461 visitors of a shopping mall (Study I) and 617 university students (Study II). The correlation between behavior in the economic experiment and digit ratios of both hands is not statistically significant in either study. In contrast, we find a negative and statistically significant relationship between psychometric self-reported measures of competitiveness and right hand digit ratios (R2D:4D) in both studies. This relationship is especially strong for younger people. Hence, this study provides some robust empirical evidence for a negative association between R2D:4D and self-reported competitiveness. We discuss potential reasons why digit ratio may relate differently to behaviors in specific economics experiments and to self-reported general competitiveness.

  7. Digit Ratio (2D:4D Predicts Self-Reported Measures of General Competitiveness, but Not Behavior in Economic Experiments

    Directory of Open Access Journals (Sweden)

    Werner Bönte

    2017-12-01

    Full Text Available The ratio of index finger length to ring finger length (2D:4D is considered to be a putative biomarker of prenatal androgen exposure (PAE, with previous research suggesting that 2D:4D is associated with human behaviors, especially sex-typical behaviors. This study empirically examines the relationship between 2D:4D and individual competitiveness, a behavioral trait that is found to be sexually dimorphic. We employ two related, but distinct, measures of competitiveness, namely behavioral measures obtained from economic experiments and psychometric self-reported measures. Our analyses are based on two independent data sets obtained from surveys and economic experiments with 461 visitors of a shopping mall (Study I and 617 university students (Study II. The correlation between behavior in the economic experiment and digit ratios of both hands is not statistically significant in either study. In contrast, we find a negative and statistically significant relationship between psychometric self-reported measures of competitiveness and right hand digit ratios (R2D:4D in both studies. This relationship is especially strong for younger people. Hence, this study provides some robust empirical evidence for a negative association between R2D:4D and self-reported competitiveness. We discuss potential reasons why digit ratio may relate differently to behaviors in specific economics experiments and to self-reported general competitiveness.

  8. Image pre-filtering for measurement error reduction in digital image correlation

    Science.gov (United States)

    Zhou, Yihao; Sun, Chen; Song, Yuntao; Chen, Jubing

    2015-02-01

    In digital image correlation, the sub-pixel intensity interpolation causes a systematic error in the measured displacements. The error increases toward high-frequency component of the speckle pattern. In practice, a captured image is usually corrupted by additive white noise. The noise introduces additional energy in the high frequencies and therefore raises the systematic error. Meanwhile, the noise also elevates the random error which increases with the noise power. In order to reduce the systematic error and the random error of the measurements, we apply a pre-filtering to the images prior to the correlation so that the high-frequency contents are suppressed. Two spatial-domain filters (binomial and Gaussian) and two frequency-domain filters (Butterworth and Wiener) are tested on speckle images undergoing both simulated and real-world translations. By evaluating the errors of the various combinations of speckle patterns, interpolators, noise levels, and filter configurations, we come to the following conclusions. All the four filters are able to reduce the systematic error. Meanwhile, the random error can also be reduced if the signal power is mainly distributed around DC. For high-frequency speckle patterns, the low-pass filters (binomial, Gaussian and Butterworth) slightly increase the random error and Butterworth filter produces the lowest random error among them. By using Wiener filter with over-estimated noise power, the random error can be reduced but the resultant systematic error is higher than that of low-pass filters. In general, Butterworth filter is recommended for error reduction due to its flexibility of passband selection and maximal preservation of the allowed frequencies. Binomial filter enables efficient implementation and thus becomes a good option if computational cost is a critical issue. While used together with pre-filtering, B-spline interpolator produces lower systematic error than bicubic interpolator and similar level of the random

  9. An FPGA-Integrated Time-to-Digital Converter Based on a Ring Oscillator for Programmable Delay Line Resolution Measurement

    Directory of Open Access Journals (Sweden)

    Chao Chen

    2014-01-01

    Full Text Available We describe the architecture of a time-to-digital converter (TDC, specially intended to measure the delay resolution of a programmable delay line (PDL. The configuration, which consists of a ring oscillator, a frequency divider (FD, and a period measurement circuit (PMC, is implemented in a field programmable gate array (FPGA device. The ring oscillator realized in loop containing a PDL and a look-up table (LUT generates periodic oscillatory pulses. The FD amplifies the oscillatory period from nanosecond range to microsecond range. The time-to-digital conversion is based on counting the number of clock cycles between two consecutive pulses of the FD by the PMC. Experiments have been conducted to verify the performance of the TDC. The achieved relative errors for four PDLs are within 0.50%–1.21% and the TDC has an equivalent resolution of about 0.4 ps.

  10. Validity and reliability of a low-cost digital dynamometer for measuring isometric strength of lower limb.

    Science.gov (United States)

    Romero-Franco, Natalia; Jiménez-Reyes, Pedro; Montaño-Munuera, Juan A

    2017-11-01

    Lower limb isometric strength is a key parameter to monitor the training process or recognise muscle weakness and injury risk. However, valid and reliable methods to evaluate it often require high-cost tools. The aim of this study was to analyse the concurrent validity and reliability of a low-cost digital dynamometer for measuring isometric strength in lower limb. Eleven physically active and healthy participants performed maximal isometric strength for: flexion and extension of ankle, flexion and extension of knee, flexion, extension, adduction, abduction, internal and external rotation of hip. Data obtained by the digital dynamometer were compared with the isokinetic dynamometer to examine its concurrent validity. Data obtained by the digital dynamometer from 2 different evaluators and 2 different sessions were compared to examine its inter-rater and intra-rater reliability. Intra-class correlation (ICC) for validity was excellent in every movement (ICC > 0.9). Intra and inter-tester reliability was excellent for all the movements assessed (ICC > 0.75). The low-cost digital dynamometer demonstrated strong concurrent validity and excellent intra and inter-tester reliability for assessing isometric strength in the main lower limb movements.

  11. Clinical performance evaluation of total protein measurement by digital refractometry and characterization of non-protein solute interferences

    Directory of Open Access Journals (Sweden)

    Joshua J.H. Hunsaker

    2016-12-01

    Full Text Available Objectives: Refractometric methods to measure total protein (TP in serum and plasma specimens have been replaced by automated biuret methods in virtually all routine clinical testing. A subset of laboratories, however, still report using refractometry to measure TP in conjunction with serum protein electrophoresis. The objective of this study was therefore to conduct a modern performance evaluation of a digital refractometer for TP measurement. Design and methods: Performance evaluation of a MISCO Palm Abbe™ digital refractometer was conducted through device familiarization, carryover, precision, accuracy, linearity, analytical sensitivity, analytical specificity, and reference interval verification. Comparison assays included a manual refractometer and an automated biuret assay. Results: Carryover risk was eliminated using a demineralized distilled water (ddH2O wash step. Precision studies demonstrated overall imprecision of 2.2% CV (low TP pool and 0.5% CV (high TP pool. Accuracy studies demonstrated correlation to both manual refractometry and the biuret method. An overall positive bias (+5.0% was observed versus the biuret method. On average, outlier specimens had an increased triglyceride concentration. Linearity was verified using mixed dilutions of: a low and high concentration patient pools, or b albumin-spiked ddH2O and high concentration patient pool. Decreased recovery was observed using ddH2O dilutions at low TP concentrations. Significant interference was detected at high concentrations of glucose (>267 mg/dL and triglycerides (>580 mg/dL. Current laboratory reference intervals for TP were verified. Conclusions: Performance characteristics of this digital refractometer were validated in a clinical laboratory setting. Biuret method remains the preferred assay for TP measurement in routine clinical analyses. Keywords: Refractometry, Digital refractometry, Total protein, Biuret, Serum protein electrophoresis, Monoclonal

  12. Diameter and axial position measurement of micrometric particles by in-line digital holography using wavelet transform

    International Nuclear Information System (INIS)

    Torres, Y M; Amezquita, R; Monroy, F

    2011-01-01

    In this paper, the size and axial position of micrometric particles is obtained for an in-line Fraunhofer holography setup. The hologram reconstruction was realized using the wavelet transform. By digital image processing tools, the size distribution histogram for the particles in the sample was obtained. The contrast measurement in the amplitude reconstruction presents a peak when the axial coordinate and the register distance are equal. This fact lets the axial position in the sample be determined.

  13. The impact of digitalization on marketing communications measurement process : case of global B2B industrial companies

    OpenAIRE

    Järvinen, Joel

    2011-01-01

    The stature of marketing communications function is under a threat within the firms. As the board of management tends to demand the profitability of all business activities, marketing practitioners have for a long time been unable to credibly show the link between marketing communications actions and financial value. Fortunately, the digitalization has offered new insights and opportunities to make the marketing communications actions more measureable. “Everything can be tracked” is an often ...

  14. Dynamic positron emission tomography image restoration via a kinetics-induced bilateral filter.

    Directory of Open Access Journals (Sweden)

    Zhaoying Bian

    Full Text Available Dynamic positron emission tomography (PET imaging is a powerful tool that provides useful quantitative information on physiological and biochemical processes. However, low signal-to-noise ratio in short dynamic frames makes accurate kinetic parameter estimation from noisy voxel-wise time activity curves (TAC a challenging task. To address this problem, several spatial filters have been investigated to reduce the noise of each frame with noticeable gains. These filters include the Gaussian filter, bilateral filter, and wavelet-based filter. These filters usually consider only the local properties of each frame without exploring potential kinetic information from entire frames. Thus, in this work, to improve PET parametric imaging accuracy, we present a kinetics-induced bilateral filter (KIBF to reduce the noise of dynamic image frames by incorporating the similarity between the voxel-wise TACs using the framework of bilateral filter. The aim of the proposed KIBF algorithm is to reduce the noise in homogeneous areas while preserving the distinct kinetics of regions of interest. Experimental results on digital brain phantom and in vivo rat study with typical (18F-FDG kinetics have shown that the present KIBF algorithm can achieve notable gains over other existing algorithms in terms of quantitative accuracy measures and visual inspection.

  15. Bilateral nephroblastoma - case report

    International Nuclear Information System (INIS)

    Luczynska, E.; Aniol, J.

    2008-01-01

    Wilms tumor is the most common renal tumor in children Synchronous bilateral Wilms tumor (BWT) accounts for 5% of all patients registered to the National Wilms Tumor Study Group (NWSTG). A 28-year-old female patient was presented to Oncology Institute with right kidney tumor. Her left kidney was resected due to Wilms tumor in the sixth month of her life. Abdominal ultrasound was performed and demonstrated a massive right kidney tumor. Then the abdominal CT was undertaken with the use of 16-slice CT scanner, revealing rotation displacement of the right kidney, with signs of compensative overgrowth and displaced upwards. In the lower and peripheral part of the kidney a nodular mass 7 X 10 X 9 cm in size was visible. The tumor was well-demarcated, showing heterogeneous contrast enhancement, extending from the inferio-lateral renal pole.The tumor was adjacent to iliopsoas muscle and abdominal cavity walls; no infiltration of those structures was noted. Described lesion surrounded inferio-medial part of the kidney, approaching kidney pelvis without infiltrating them. Supero-anterior and medial part of the kidney showed normal structure with correct contrasted urine excretion. Lymph nodes enlargement within periaortal area was not detected. Surgical procedure was performed resulting in excision of the tumor with kidney preservation. Histopathology examination revealed nephroblastoma. The tumor was surrounded by a thin, fibrous capsule. Surrounding parenchyma and far tissue were not involved. The CT examination performed 4 months after nephron sparing surgery revealed: right kidney of 137 X 51 mm in size, normally located, with correct structure and function. Multislice abdominal CT have clearly visualized the tumor of the single kidney, showing precise localization of the mass with relation to the kidney pelvis and vessels, allowing for nephron sparing surgical excision. (authors)

  16. Fast collimated neutron flux measurement using stilbene scintillator and flashy analog-to-digital converter in JT-60U

    International Nuclear Information System (INIS)

    Ishikawa, M.; Itoga, T.; Okuji, T.; Nakhostin, M.; Shinohara, K.; Hayashi, T.; Sukegawa, A.; Baba, M.; Nishitani, T.

    2006-01-01

    A line-integrated neutron emission profile is routinely measured using the radial neutron collimator system in JT-60U tokamak. Stilbene neuron detectors (SNDs), which combine a stilbene organic crystal scintillation detector (SD) with an analog neutron-gamma pulse shape discrimination (PSD) circuit, have been used to measure collimated neutron flux. Although the SND has many advantages as a neutron detector, the maximum count rate is limited up to ∼1x10 5 counts/s due to the analog PSD circuit. To overcome this issue, a digital signal processing system (DSPS) using a flash analog-to-digital converter (Acqiris DC252, 8 GHz, 10 bits) has been developed at Cyclotron and Radioisotope Center in Tohoku University. In this system anode signals from photomultiplier of the SD are directory stored and digitized. Then, the PSD between neutrons and gamma rays is performed using software. The DSPS has been installed in the vertical neutron collimator system in JT-60U and applied to deuterium experiments. It is confirmed that the PSD is sufficiently performed and collimated neutron flux is successfully measured with count rate up to ∼5x10 5 counts/s without the effect of pileup of detected pulses. The performance of the DSPS as a neutron detector, which supersedes the SND, is demonstrated

  17. Fully automated joint space width measurement and digital X-ray radiogrammetry in early RA

    NARCIS (Netherlands)

    Platten, Michael; Kisten, Yogan; Kälvesten, Johan; Arnaud, Laurent; Forslind, Kristina; van Vollenhoven, Ronald

    2017-01-01

    To study fully automated digital joint space width (JSW) and bone mineral density (BMD) in relation to a conventional radiographic scoring method in early rheumatoid arthritis (eRA). Radiographs scored by the modified Sharp van der Heijde score (SHS) in patients with eRA were acquired from the

  18. Measurement of cytokine and adhesion molecule expression in synovial tissue by digital image analysis

    NARCIS (Netherlands)

    Kraan, M. C.; Smith, M. D.; Weedon, H.; Ahern, M. J.; Breedveld, F. C.; Tak, P. P.

    2001-01-01

    Digital image analysis (DIA) offers the opportunity to quantify the stained area and staining intensity when synovial tissue (ST) is investigated by immunohistochemical analysis. This study aimed at determining the sensitivity of DIA compared with semiquantitative analysis (SQA). Paired ST samples

  19. Average glandular dose in paired digital mammography and digital breast tomosynthesis acquisitions in a population based screening program: effects of measuring breast density, air kerma and beam quality

    Science.gov (United States)

    Helge Østerås, Bjørn; Skaane, Per; Gullien, Randi; Catrine Trægde Martinsen, Anne

    2018-02-01

    The main purpose was to compare average glandular dose (AGD) for same-compression digital mammography (DM) and digital breast tomosynthesis (DBT) acquisitions in a population based screening program, with and without breast density stratification, as determined by automatically calculated breast density (Quantra™). Secondary, to compare AGD estimates based on measured breast density, air kerma and half value layer (HVL) to DICOM metadata based estimates. AGD was estimated for 3819 women participating in the screening trial. All received craniocaudal and mediolateral oblique views of each breasts with paired DM and DBT acquisitions. Exposure parameters were extracted from DICOM metadata. Air kerma and HVL were measured for all beam qualities used to acquire the mammograms. Volumetric breast density was estimated using Quantra™. AGD was estimated using the Dance model. AGD reported directly from the DICOM metadata was also assessed. Mean AGD was 1.74 and 2.10 mGy for DM and DBT, respectively. Mean DBT/DM AGD ratio was 1.24. For fatty breasts: mean AGD was 1.74 and 2.27 mGy for DM and DBT, respectively. For dense breasts: mean AGD was 1.73 and 1.79 mGy, for DM and DBT, respectively. For breasts of similar thickness, dense breasts had higher AGD for DM and similar AGD for DBT. The DBT/DM dose ratio was substantially lower for dense compared to fatty breasts (1.08 versus 1.33). The average c-factor was 1.16. Using previously published polynomials to estimate glandularity from thickness underestimated the c-factor by 5.9% on average. Mean AGD error between estimates based on measurements (air kerma and HVL) versus DICOM header data was 3.8%, but for one mammography unit as high as 7.9%. Mean error of using the AGD value reported in the DICOM header was 10.7 and 13.3%, respectively. Thus, measurement of breast density, radiation dose and beam quality can substantially affect AGD estimates.

  20. CLUSTERING OF SLOAN DIGITAL SKY SURVEY III PHOTOMETRIC LUMINOUS GALAXIES: THE MEASUREMENT, SYSTEMATICS, AND COSMOLOGICAL IMPLICATIONS

    International Nuclear Information System (INIS)

    Ho, Shirley; White, Martin; Schlegel, David J.; Seljak, Uros; Reid, Beth; Cuesta, Antonio; Padmanabhan, Nikhil; Seo, Hee-Jong; De Putter, Roland; Ross, Ashley J.; Percival, Will J.; Saito, Shun; Schlafly, Eddie; Hernández-Monteagudo, Carlos; Sánchez, Ariel G.; Blanton, Michael; Skibba, Ramin; Schneider, Don; Mena, Olga; Viel, Matteo

    2012-01-01

    The Sloan Digital Sky Survey (SDSS) surveyed 14,555 deg 2 , and delivered over a trillion pixels of imaging data. We present a study of galaxy clustering using 900,000 luminous galaxies with photometric redshifts, spanning between z = 0.45 and z = 0.65, constructed from the SDSS using methods described in Ross et al. This data set spans 11,000 deg 2 and probes a volume of 3 h –3 Gpc 3 , making it the largest volume ever used for galaxy clustering measurements. We describe in detail the construction of the survey window function and various systematics affecting our measurement. With such a large volume, high-precision cosmological constraints can be obtained given careful control and understanding of the observational systematics. We present a novel treatment of the observational systematics and its applications to the clustering signals from the data set. In this paper, we measure the angular clustering using an optimal quadratic estimator at four redshift slices with an accuracy of ∼15%, with a bin size of δ l = 10 on scales of the baryon acoustic oscillations (BAOs; at l ∼ 40-400). We also apply corrections to the power spectra due to systematics and derive cosmological constraints using the full shape of the power spectra. For a flat ΛCDM model, when combined with cosmic microwave background Wilkinson Microwave Anisotropy Probe 7 (WMAP7) and H 0 constraints from using 600 Cepheids observed by Wide Field Camera 3 (WFC3; HST), we find Ω Λ = 0.73 ± 0.019 and H 0 to be 70.5 ± 1.6 s –1 Mpc –1 km. For an open ΛCDM model, when combined with WMAP7 + HST, we find Ω K = 0.0035 ± 0.0054, improved over WMAP7+HST alone by 40%. For a wCDM model, when combined with WMAP7+HST+SN, we find w = –1.071 ± 0.078, and H 0 to be 71.3 ± 1.7 s –1 Mpc –1 km, which is competitive with the latest large-scale structure constraints from large spectroscopic surveys such as the SDSS Data Release 7 (DR7) and WiggleZ. We also find that systematic-corrected power

  1. CLUSTERING OF SLOAN DIGITAL SKY SURVEY III PHOTOMETRIC LUMINOUS GALAXIES: THE MEASUREMENT, SYSTEMATICS, AND COSMOLOGICAL IMPLICATIONS

    Energy Technology Data Exchange (ETDEWEB)

    Ho, Shirley; White, Martin; Schlegel, David J.; Seljak, Uros; Reid, Beth [Lawrence Berkeley National Laboratory, 1 Cyclotron Rd, MS 50R-5045, Berkeley, CA 94720 (United States); Cuesta, Antonio; Padmanabhan, Nikhil [Yale Center for Astronomy and Astrophysics, Yale University, New Haven, CT 06511 (United States); Seo, Hee-Jong [Berkeley Center for Cosmological Physics, LBL and Department of Physics, University of California, Berkeley, CA 94720 (United States); De Putter, Roland [ICC, University of Barcelona (IEEC-UB), Marti i Franques 1, E-08028 Barcelona (Spain); Ross, Ashley J.; Percival, Will J. [Institute of Cosmology and Gravitation, Dennis Sciama Building, University of Portsmouth, Portsmouth PO1 3FX (United Kingdom); Saito, Shun [Department of Astronomy, University of California Berkeley, CA (United States); Schlafly, Eddie [Department of Astronomy, Harvard University, 60 Garden St. MS 20, Cambridge, MA 02138 (United States); Hernandez-Monteagudo, Carlos [Centro de Estudios de Fisica del Cosmos de Aragon (CEFCA), Plaza de San Juan 1, planta 2, E-44001 Teruel (Spain); Sanchez, Ariel G. [Max-Planck-Institut fuer Extraterrestrische Physik, Giessenbachstrasse 1, D-85748 Garching (Germany); Blanton, Michael [Center for Cosmology and Particle Physics, Department of Physics, New York University, 4 Washington Place, New York, NY 10003 (United States); Skibba, Ramin [Steward Observatory, University of Arizona, 933 N. Cherry Avenue, Tucson, AZ 85721 (United States); Schneider, Don [Department of Astronomy and Astrophysics, The Pennsylvania State University, University Park, PA 16802 (United States); Mena, Olga [Instituto de Fisica Corpuscular, Universidad de Valencia-CSIC (Spain); Viel, Matteo, E-mail: cwho@lbl.gov [INAF-Osservatorio Astronomico di Trieste, Via G. B. Tiepolo 11, I-34131 Trieste (Italy); and others

    2012-12-10

    The Sloan Digital Sky Survey (SDSS) surveyed 14,555 deg{sup 2}, and delivered over a trillion pixels of imaging data. We present a study of galaxy clustering using 900,000 luminous galaxies with photometric redshifts, spanning between z = 0.45 and z = 0.65, constructed from the SDSS using methods described in Ross et al. This data set spans 11,000 deg{sup 2} and probes a volume of 3 h {sup -3} Gpc{sup 3}, making it the largest volume ever used for galaxy clustering measurements. We describe in detail the construction of the survey window function and various systematics affecting our measurement. With such a large volume, high-precision cosmological constraints can be obtained given careful control and understanding of the observational systematics. We present a novel treatment of the observational systematics and its applications to the clustering signals from the data set. In this paper, we measure the angular clustering using an optimal quadratic estimator at four redshift slices with an accuracy of {approx}15%, with a bin size of {delta}{sub l} = 10 on scales of the baryon acoustic oscillations (BAOs; at l {approx} 40-400). We also apply corrections to the power spectra due to systematics and derive cosmological constraints using the full shape of the power spectra. For a flat {Lambda}CDM model, when combined with cosmic microwave background Wilkinson Microwave Anisotropy Probe 7 (WMAP7) and H{sub 0} constraints from using 600 Cepheids observed by Wide Field Camera 3 (WFC3; HST), we find {Omega}{sub {Lambda}} = 0.73 {+-} 0.019 and H{sub 0} to be 70.5 {+-} 1.6 s{sup -1} Mpc{sup -1} km. For an open {Lambda}CDM model, when combined with WMAP7 + HST, we find {Omega}{sub K} = 0.0035 {+-} 0.0054, improved over WMAP7+HST alone by 40%. For a wCDM model, when combined with WMAP7+HST+SN, we find w = -1.071 {+-} 0.078, and H{sub 0} to be 71.3 {+-} 1.7 s{sup -1} Mpc{sup -1} km, which is competitive with the latest large-scale structure constraints from large spectroscopic

  2. Measures of digit span and verbal rehearsal speed in deaf children after more than 10 years of cochlear implantation.

    Science.gov (United States)

    Pisoni, David B; Kronenberger, William G; Roman, Adrienne S; Geers, Ann E

    2011-02-01

    Conventional assessments of outcomes in deaf children with cochlear implants (CIs) have focused primarily on endpoint or product measures of speech and language. Little attention has been devoted to understanding the basic underlying core neurocognitive factors involved in the development and processing of speech and language. In this study, we examined the development of factors related to the quality of phonological information in immediate verbal memory, including immediate memory capacity and verbal rehearsal speed, in a sample of deaf children after >10 yrs of CI use and assessed the correlations between these two process measures and a set of speech and language outcomes. Of an initial sample of 180 prelingually deaf children with CIs assessed at ages 8 to 9 yrs after 3 to 7 yrs of CI use, 112 returned for testing again in adolescence after 10 more years of CI experience. In addition to completing a battery of conventional speech and language outcome measures, subjects were administered the Wechsler Intelligence Scale for Children-III Digit Span subtest to measure immediate verbal memory capacity. Sentence durations obtained from the McGarr speech intelligibility test were used as a measure of verbal rehearsal speed. Relative to norms for normal-hearing children, Digit Span scores were well below average for children with CIs at both elementary and high school ages. Improvement was observed over the 8-yr period in the mean longest digit span forward score but not in the mean longest digit span backward score. Longest digit span forward scores at ages 8 to 9 yrs were significantly correlated with all speech and language outcomes in adolescence, but backward digit spans correlated significantly only with measures of higher-order language functioning over that time period. While verbal rehearsal speed increased for almost all subjects between elementary grades and high school, it was still slower than the rehearsal speed obtained from a control group of normal

  3. Bilateral Olecranon Tophaceous Gout Bursitis

    Directory of Open Access Journals (Sweden)

    Güzelali Özdemir

    2017-01-01

    Full Text Available In this case, we present a patient with the diagnosis of bilateral olecranon tophaceous gout. After the surgical treatment, there was no limitation of range of motion or wound problem at 6th month control.

  4. Bilateral, independent juvenile nasopharyngeal angiofibroma

    DEFF Research Database (Denmark)

    Mørkenborg, Marie-Louise; Frendø, M; Stavngaard, T

    2015-01-01

    BACKGROUND: Juvenile nasopharyngeal angiofibroma is a benign, vascular tumour that primarily occurs in adolescent males. Despite its benign nature, aggressive growth patterns can cause potential life-threatening complications. Juvenile nasopharyngeal angiofibroma is normally unilateral, originating...... from the sphenopalatine artery, but bilateral symptoms can occur if a large tumour extends to the contralateral side of the nasopharynx. This paper presents the first reported case of true bilateral extensive juvenile nasopharyngeal angiofibroma involving clinically challenging pre-surgical planning...... embolisation. Radical removal performed as one-step, computer-assisted functional endoscopic sinus surgery was performed. The follow-up period was uncomplicated. CONCLUSION: This case illustrates the importance of suspecting bilateral juvenile nasopharyngeal angiofibroma in patients presenting with bilateral...

  5. Bilateral papillary renal cell carcinoma

    International Nuclear Information System (INIS)

    Gossios, K.; Vazakas, P.; Argyropoulou, M.; Stefanaki, S.; Stavropoulos, N.E.

    2001-01-01

    Papillary renal cell carcinoma is a subgroup of malignant renal epithelial neoplasms. We report the clinical and imaging findings of a case with multifocal and bilateral renal cell carcinoma which are nonspecific. (orig.)

  6. Bilateral internal laryngoceles mimicking asthma

    Directory of Open Access Journals (Sweden)

    Elif A Aksoy

    2013-01-01

    Full Text Available Laryngocele is an air-filled, abnormal dilation of the laryngeal saccule that extends upward within the false vocal fold, in communication with the laryngeal lumen. A case of 43-year-old male with bilateral internal laryngoceles, who has been treated as asthma for 4 years, is presented. The patient had dyspnea, cough, and excessive phlegm for a month and a late onset stridor. Flexible nasopharyngolaryngoscopy showed bilateral cystic enlargements of the false vocal folds and true vocal folds could not be visualized. Laryngeal CT without contrast enhancement showed bilateral internal laryngoceles. Submucosal total excision of bilateral cystic masses including parts of false vocal folds was performed. The symptoms resolved immediately after surgery. Although the incidence of internal laryngocele is rare, it should be remembered in the differential diagnosis of upper airway problems and diagnostic flexible nasopharnygolaryngoscopy is routinely indicated for airway evaluation in at-risk patients.

  7. Simultaneous bilateral patellar tendon rupture ?

    OpenAIRE

    Moura, Diogo Lino; Marques, Jos? Pedro; Lucas, Francisco Manuel; Fonseca, Fernando Pereira

    2016-01-01

    Bilateral patellar tendon rupture is a rare entity, often associated with systemic diseases and patellar tendinopathy. The authors report a rare case of a 34-year-old man with simultaneous bilateral rupture of the patellar tendon caused by minor trauma. The patient is a retired basketball player with no past complaints of chronic knee pain and a history of steroid use. Surgical management consisted in primary end-to-end tendon repair protected temporarily with cerclage wiring, followed by a s...

  8. Bilateral sarkoidose i glandula parotis

    DEFF Research Database (Denmark)

    Hahn, Pernille; Krogdahl, Annelise; Godballe, Christian

    2012-01-01

    We describe an unusual case of sarcoidosis in which the patient presented with a bilateral swelling of the parotid salivary glands and no other manifestation of the disease. Sarcoidosis is a multisystem granulomatous disorder of unknown cause in which there may be multiple exocrine involvement......, including the salivary glands. This case emphasises the importance of including sarcoidosis in the differential diagnosis of bilateral parotid swelling....

  9. Light-reflection random-target method for measurement of the modulation transfer function of a digital video-camera

    Science.gov (United States)

    Pospisil, J.; Jakubik, P.; Machala, L.

    2005-11-01

    This article reports the suggestion, realization and verification of the newly developed measuring means of the noiseless and locally shift-invariant modulation transfer function (MTF) of a digital video camera in a usual incoherent visible region of optical intensity, especially of its combined imaging, detection, sampling and digitizing steps which are influenced by the additive and spatially discrete photodetector, aliasing and quantization noises. Such means relates to the still camera automatic working regime and static two-dimensional spatially continuous light-reflection random target of white-noise property. The introduced theoretical reason for such a random-target method is also performed under exploitation of the proposed simulation model of the linear optical intensity response and possibility to express the resultant MTF by a normalized and smoothed rate of the ascertainable output and input power spectral densities. The random-target and resultant image-data were obtained and processed by means of a processing and evaluational PC with computation programs developed on the basis of MATLAB 6.5E The present examples of results and other obtained results of the performed measurements demonstrate the sufficient repeatability and acceptability of the described method for comparative evaluations of the performance of digital video cameras under various conditions.

  10. Closure of digital arteries in high vascular tone states as demonstrated by measurement of systolic blood pressure in the fingers

    DEFF Research Database (Denmark)

    Krähenbühl, B; Nielsen, S L; Lassen, N A

    1977-01-01

    by direct cooling or intra-arterial noradrenaline infusion caused a marked drop in FSP in the exposed fingers, but not in the non-exposed fingers of the same hand. The fact that the non-exposed fingers retained the normal (arm systolic) pressure level is taken to indicate that palmar arch blood pressure......Finger systolic blood pressure (FSP) was measured indirectly in normal subjects and patients with primary Raynaud phenomenon by applying a thin-walled plastic cuff around the finger and a strain gauge more distally to detect volume changes. Inducing a high vascular tone in one or more fingers...... also remained normal. In the high vascular tone state, a large transmural pressure difference must apparently be established before the digital arteries are forced open. The lowered opening pressure constitutes a manifestation of the closure phenomenon of the digital arteries described in patients...

  11. Micro controller based design of digital transmitters for temperature measurements in reactors

    International Nuclear Information System (INIS)

    Nassar, M.A.M.

    2011-01-01

    Temperature transmitter is one of the most important transmitters in the nuclear reactor it is used for RTD (resistance temperature detector) signal conditioning. It has built-in current excitation, instrumentation amplifier, linearization and current output circuitry which amplifies the RTD signal and gives linearization to it. It is a part of a system to get temperature and monitoring it. This system is very cost and complicated. In this work a digital system is implemented by using micro controller techniques that replaces the existing system, one chip (PIC16f877) is used to build a digital system, which is more accurate and give more performance and low costs . RTD is the sensing element of temperature, its resistance increases with temperature. There are many types of transmitters in the reactor such as temperature, pressure, level and flow but temperature one is chosen because of temperature is one of the most important parameters in process control.

  12. Semi-automated digital measurement as the method of choice for beta cell mass analysis.

    Directory of Open Access Journals (Sweden)

    Violette Coppens

    Full Text Available Pancreas injury by partial duct ligation (PDL activates beta cell differentiation and proliferation in adult mouse pancreas but remains controversial regarding the anticipated increase in beta cell volume. Several reports unable to show beta cell volume augmentation in PDL pancreas used automated digital image analysis software. We hypothesized that fully automatic beta cell morphometry without manual micrograph artifact remediation introduces bias and therefore might be responsible for reported discrepancies and controversy. However, our present results prove that standard digital image processing with automatic thresholding is sufficiently robust albeit less sensitive and less adequate to demonstrate a significant increase in beta cell volume in PDL versus Sham-operated pancreas. We therefore conclude that other confounding factors such as quality of surgery, selection of samples based on relative abundance of the transcription factor Neurogenin 3 (Ngn3 and tissue processing give rise to inter-laboratory inconsistencies in beta cell volume quantification in PDL pancreas.

  13. Investigating the issue of copyright and security measures in digital libraries

    Directory of Open Access Journals (Sweden)

    Sedigheh Ahmadi Fasih

    2013-11-01

    Full Text Available During the past few years, digital libraries have been the primary source of retrieving necessary information. IT helps many scholars have the access to recently published value added researches around the world. However, information security and copyright concerns are among the most important issues and there must be good rules and regulation to protect authors against any sort of copyright violation. In this paper, we present an empirical investigation to find out about the status of copyright issues in one of Iranian libraries. The proposed study of this paper designs a questionnaire in Likert scale and distributes it among 96 librarian experts. Cronbach alpha is equal to 0.76, which is well above the minimum acceptable level. The results of our investigation indicate that although expert believe the status of copyright is in desirable level when the level of significance is five percent, there are some concerns on some issues. In other words, experts believed that all copyrights are not well protected and digital libraries do not follow governmental rules and regulation on fully protecting authors’ rights. In addition, experts believed that the security of sources available on digital libraries is not well protected.

  14. Investigations for the use of the fast digitizers with C6D6 detectors for radiative capture measurements at GELINA

    International Nuclear Information System (INIS)

    Mihailescu, L.C.; Borella, A.; Massimi, C.; Schillebeeckx, P.

    2009-01-01

    The relatively long dead time in conventional data acquisition systems that provide simultaneously the pulse height and the time information for the detected events hinders cross-section measurements with high count rates. This is the case for capture cross-section measurements at the time-of-flight facility GELINA using high radioactive samples or thick samples of materials having strong resonances. Either the high average count rate (e.g. due to the radioactivity of the sample) or the high instantaneous count rate for strong resonances results in a large dead time correction. One solution to reduce the impact of the dead time is the use of a data acquisition system based on fast digitizers. The performances of two commercial digitizers (CAEN N172B and Acqiris DC282), coupled to a C 6 D 6 scintillator, have been tested in terms of pulse height linearity and resolution, dead time and time resolution. The signal processing was done on-line obtaining simultaneously the pulse height and time information for each detected event. With both digitizers a comparable pulse height linearity and resolution has been obtained as with a conventional system. The total dead time of both digital systems is at least a factor 5 shorter than the one for the conventional system. The main difference in performance between the two digitizers is the time resolution. For a relatively large scintillator, a time resolution of about 2 ns has been achieved with the DC282 module and the conventional system while the time resolution was limited to 15 ns with the CAEN N1728B module. For most nuclei a 15 ns time resolution is sufficient to perform resonance shape analysis. Therefore, the CAEN N1728B module can be used for the majority of capture cross-section measurements at GELINA. However, for nuclei with low level density, for which the resolved resonance region extends to the keV-region, a better time resolution is required and the Acqiris DC282 module has to be used.

  15. Clinical performance evaluation of total protein measurement by digital refractometry and characterization of non-protein solute interferences.

    Science.gov (United States)

    Hunsaker, Joshua J H; Wyness, Sara P; Snow, Taylor M; Genzen, Jonathan R

    2016-12-01

    Refractometric methods to measure total protein (TP) in serum and plasma specimens have been replaced by automated biuret methods in virtually all routine clinical testing. A subset of laboratories, however, still report using refractometry to measure TP in conjunction with serum protein electrophoresis. The objective of this study was therefore to conduct a modern performance evaluation of a digital refractometer for TP measurement. Performance evaluation of a MISCO Palm Abbe™ digital refractometer was conducted through device familiarization, carryover, precision, accuracy, linearity, analytical sensitivity, analytical specificity, and reference interval verification. Comparison assays included a manual refractometer and an automated biuret assay. Carryover risk was eliminated using a demineralized distilled water (ddH 2 O) wash step. Precision studies demonstrated overall imprecision of 2.2% CV (low TP pool) and 0.5% CV (high TP pool). Accuracy studies demonstrated correlation to both manual refractometry and the biuret method. An overall positive bias (+5.0%) was observed versus the biuret method. On average, outlier specimens had an increased triglyceride concentration. Linearity was verified using mixed dilutions of: a) low and high concentration patient pools, or b) albumin-spiked ddH 2 O and high concentration patient pool. Decreased recovery was observed using ddH 2 O dilutions at low TP concentrations. Significant interference was detected at high concentrations of glucose (>267 mg/dL) and triglycerides (>580 mg/dL). Current laboratory reference intervals for TP were verified. Performance characteristics of this digital refractometer were validated in a clinical laboratory setting. Biuret method remains the preferred assay for TP measurement in routine clinical analyses.

  16. Bilateral Diabetic Papillopathy and Metabolic Control

    DEFF Research Database (Denmark)

    Ostri, Christoffer; Lund-Andersen, Henrik; Sander, Birgit

    2010-01-01

    OBJECTIVE: The pathogenesis of diabetic papillopathy largely is unknown, but case reports suggest that it may follow rapidly improved metabolic control. The present study was designed to investigate this hypothesis. DESIGN: Retrospective case-control study. PARTICIPANTS: Two thousand sixty......-six patients with type 1 diabetes. METHODS: Review of clinical, photographic, and clinical chemistry records from a large diabetology and ophthalmology unit between 2001 and 2008. MAIN OUTCOME MEASURES: Simultaneous, bilateral diabetic papillopathy. RESULTS: The mean follow-up was 4.9 years. During 10 020...... patient-years of observation, bilateral diabetic papillopathy developed in 5 patients. During the year preceding this incident, all 5 patients had experienced a decrease in glycosylated hemoglobin A(1c) (HbA(1C)) at a maximum rate of -2.5 (mean) percentage points per quarter year, which was significantly...

  17. Low-level software for the pentek 6510 digital receiver board applied to the new AD beam measurement system

    CERN Document Server

    Angoletta, Maria Elena

    2002-01-01

    The new beam measurement system for the CERN Antiproton Decelerator heavily relies on a Pentek 6510 Digital Receiver (DRX) board. The new system goal is to extract beam parameters from pickup signals. Its digital implementation allows for higher precision, easier management of the hardware as well as modification and improvement with no hardware change. In this scheme, this innovative VME DRX board is responsible for parallel data acquisition, independent digital down conversion and processing of up to 4 digitised inputs. The in-house- developed low-level code (LLC), running on the board, takes care of several tasks, such as interfacing with the Real Time Task (RTT), data processing and board managing. The RTT runs on a PowerPC VME board and controls the DRX board as a master. The LLC is a state machine developed in C and Assembler, which services several interrupts and performs the FFT of complex input data. The DRX low-level system developed is highly modular and easily adaptable to other processing scenari...

  18. EEG activity as an objective measure of cognitive load during effortful listening: A study on pediatric subjects with bilateral, asymmetric sensorineural hearing loss.

    Science.gov (United States)

    Marsella, Pasquale; Scorpecci, Alessandro; Cartocci, Giulia; Giannantonio, Sara; Maglione, Anton Giulio; Venuti, Isotta; Brizi, Ambra; Babiloni, Fabio

    2017-08-01

    Deaf subjects with hearing aids or cochlear implants generally find it challenging to understand speech in noisy environments where a great deal of listening effort and cognitive load are invested. In prelingually deaf children, such difficulties may have detrimental consequences on the learning process and, later in life, on academic performance. Despite the importance of such a topic, currently, there is no validated test for the assessment of cognitive load during audiological tasks. Recently, alpha and theta EEG rhythm variations in the parietal and frontal areas, respectively, have been used as indicators of cognitive load in adult subjects. The aim of the present study was to investigate, by means of EEG, the cognitive load of pediatric subjects affected by asymmetric sensorineural hearing loss as they were engaged in a speech-in-noise identification task. Seven children (4F and 3M, age range = 8-16 years) affected by asymmetric sensorineural hearing loss (i.e. profound degree on one side, mild-to-severe degree on the other side) and using a hearing aid only in their better ear, were included in the study. All of them underwent EEG recording during a speech-in-noise identification task: the experimental conditions were quiet, binaural noise, noise to the better hearing ear and noise to the poorer hearing ear. The subjects' Speech Recognition Thresholds (SRT) were also measured in each test condition. The primary outcome measures were: frontal EEG Power Spectral Density (PSD) in the theta band and parietal EEG PSD in the alpha band, as assessed before stimulus (word) onset. No statistically significant differences were noted among frontal theta power levels in the four test conditions. However, parietal alpha power levels were significantly higher in the "binaural noise" and in the "noise to worse hearing ear" conditions than in the "quiet" and "noise to better hearing ear" conditions (p cognitive load during effortful listening. Significantly higher

  19. Mobile measurement setup according to IEC 62220-1-2 for DQE determination on digital mammography systems

    Science.gov (United States)

    Greiter, Matthias B.; Hoeschen, Christoph

    2010-04-01

    The international standard IEC 62220-1-2 defines the measurement procedure for determination of the detective quantum efficiency (DQE) of digital x-ray imaging devices used in mammography. A mobile setup complying to this standard and adaptable to most current systems was constructed in the Helmholtz Zentrum München to allow for an objective technical comparison of current full field digital mammography units employed in mammography screening in Germany. This article demonstrates the setup's capabilities with a focus on the measurement uncertainties of all quantities contributing to DQE measurements. Evaluation of uncertainties encompasses results from measurements on a Sectra Microdose Mammography in clinical use, as well as on a prototype of a Fujifilm Amulet system at various radiation qualities. Both systems have a high spatial resolution of 50 μm × 50 μm. The modulation transfer function (MTF), noise power spectrum (NPS) and DQE of the Sectra MDM are presented in comparison to results previously published by other authors.

  20. Digit-color synaesthesia only enhances memory for colors in a specific context: A new method of duration thresholds to measure serial recall.

    Science.gov (United States)

    Teichmann, A Lina; Nieuwenstein, Mark R; Rich, Anina N

    2017-08-01

    For digit-color synaesthetes, digits elicit vivid experiences of color that are highly consistent for each individual. The conscious experience of synaesthesia is typically unidirectional: Digits evoke colors but not vice versa. There is an ongoing debate about whether synaesthetes have a memory advantage over non-synaesthetes. One key question in this debate is whether synaesthetes have a general superiority or whether any benefit is specific to a certain type of material. Here, we focus on immediate serial recall and ask digit-color synaesthetes and controls to memorize digit and color sequences. We developed a sensitive staircase method manipulating presentation duration to measure participants' serial recall of both overlearned and novel sequences. Our results show that synaesthetes can activate digit information to enhance serial memory for color sequences. When color sequences corresponded to ascending or descending digit sequences, synaesthetes encoded these sequences at a faster rate than their non-synaesthetes counterparts and faster than non-structured color sequences. However, encoding color sequences is approximately 200 ms slower than encoding digit sequences directly, independent of group and condition, which shows that the translation process is time consuming. These results suggest memory advantages in synaesthesia require a modified dual-coding account, in which secondary (synaesthetically linked) information is useful only if it is more memorable than the primary information to be recalled. Our study further shows that duration thresholds are a sensitive method to measure subtle differences in serial recall performance. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  1. 38 CFR 4.26 - Bilateral factor.

    Science.gov (United States)

    2010-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 1 2010-07-01 2010-07-01 false Bilateral factor. 4.26... DISABILITIES General Policy in Rating § 4.26 Bilateral factor. When a partial disability results from disease... disability. The bilateral factor will be applied to such bilateral disabilities before other combinations are...

  2. Digital voltmeter

    International Nuclear Information System (INIS)

    Yohannes Kamadi; Soekarno.

    1976-01-01

    The electrical voltage measuring equipment with digital display has been made. This equipment uses four digits display with single polarity measurement and integrating system. Pulses from the oscillator will be counted and converted to the staircase voltages, and compared to the voltage measured. When the balance is already achieved, the pulse will appear at the comparator circuit. This pulse will be used to trigger univibrator circuit. The univibrator output is used as signal for stopping the counting, and when reading time T already stops, the counting system will be reset. (authors)

  3. Bilateral Endoscopic Medial Maxillectomy for Bilateral Inverted Papilloma

    Science.gov (United States)

    Kodama, Satoru; Kawano, Toshiaki; Suzuki, Masashi

    2012-01-01

    Inverted papilloma (IP) is a benign tumor of the nasal cavity and paranasal sinuses that is unilateral in most cases. Bilateral IP, involving both sides of the nasal cavity and sinuses, is extremely rare. This paper describes a large IP that filled in both sides of the nasal cavity and sinuses, mimicking association with malignancy. The tumor was successfully treated by bilateral endoscopic medial maxillectomy (EMM). The patient is without evidence of the disease 24 months after surgery. If preoperative diagnosis does not confirm the association with malignancy in IP, endoscopic sinus surgery (ESS) should be selected, and ESS, including EMM, is a good first choice of the treatment for IP. PMID:22953103

  4. Bilateral spontaneous hemotympanum: Case report

    Directory of Open Access Journals (Sweden)

    Economou Nicolas C

    2006-10-01

    Full Text Available Abstract Background The most common causes of hemotympanum are therapeutic nasal packing, epistaxis, blood disorders and blunt trauma to the head. Hemotympanum is characterized as idiopathic, when it is detected in the presence of chronic otitis media. A rare case of spontaneous bilateral hemotympanum in a patient treated with anticoagulants is presented herein. Case presentation A 72-year-old male presented with acute deterioration of hearing. In the patient's medical history aortic valve replacement 1 year before presentation was reported. Since then he had been administered regularly coumarinic anticoagulants, with INR levels maintained between 3.4 and 4.0. Otoscopy revealed the presence of bilateral hemotympanum. The audiogram showed symmetrical moderately severe mixed hearing loss bilaterally, with the conductive component predominating. Tympanograms were flat bilaterally with absent acoustic reflexes. A computerized tomography scan showed the presence of fluid in the mastoid and middle ear bilaterally. Treatment was conservative and consisted of a 10-day course of antibiotics, anticongestants and temporary interruption of the anticoagulant therapy. After 3 weeks, normal tympanic membranes were found and hearing had returned to previous levels. Conclusion Anticoagulant intake should be included in the differential diagnosis of hemotympanum, because its detection and appropriate treatment may lead to resolution of the disorder.

  5. Time Resolved Digital PIV Measurements of Flow Field Cyclic Variation in an Optical IC Engine

    Energy Technology Data Exchange (ETDEWEB)

    Jarvis, S; Justham, T; Clarke, A; Garner, C P; Hargrave, G K; Halliwell, N A [Wolfson School of Mechanical and Manufacturing Engineering, Loughborough University, Loughborough, Leicestershire, LE11 3TU (United Kingdom)

    2006-07-15

    Time resolved digital particle image velocimetry (DPIV) experimental data is presented for the in-cylinder flow field development of a motored four stroke spark ignition (SI) optical internal combustion (IC) engine. A high speed DPIV system was employed to quantify the velocity field development during the intake and compression stroke at an engine speed of 1500 rpm. The results map the spatial and temporal development of the in-cylinder flow field structure allowing comparison between traditional ensemble average and cycle average flow field structures. Conclusions are drawn with respect to engine flow field cyclic variations.

  6. Time Resolved Digital PIV Measurements of Flow Field Cyclic Variation in an Optical IC Engine

    International Nuclear Information System (INIS)

    Jarvis, S; Justham, T; Clarke, A; Garner, C P; Hargrave, G K; Halliwell, N A

    2006-01-01

    Time resolved digital particle image velocimetry (DPIV) experimental data is presented for the in-cylinder flow field development of a motored four stroke spark ignition (SI) optical internal combustion (IC) engine. A high speed DPIV system was employed to quantify the velocity field development during the intake and compression stroke at an engine speed of 1500 rpm. The results map the spatial and temporal development of the in-cylinder flow field structure allowing comparison between traditional ensemble average and cycle average flow field structures. Conclusions are drawn with respect to engine flow field cyclic variations

  7. Time Resolved Digital PIV Measurements of Flow Field Cyclic Variation in an Optical IC Engine

    Science.gov (United States)

    Jarvis, S.; Justham, T.; Clarke, A.; Garner, C. P.; Hargrave, G. K.; Halliwell, N. A.

    2006-07-01

    Time resolved digital particle image velocimetry (DPIV) experimental data is presented for the in-cylinder flow field development of a motored four stroke spark ignition (SI) optical internal combustion (IC) engine. A high speed DPIV system was employed to quantify the velocity field development during the intake and compression stroke at an engine speed of 1500 rpm. The results map the spatial and temporal development of the in-cylinder flow field structure allowing comparison between traditional ensemble average and cycle average flow field structures. Conclusions are drawn with respect to engine flow field cyclic variations.

  8. The reliability of the Associate Platinum digital foot scanner in measuring previously developed footprint characteristics: a technical note.

    Science.gov (United States)

    Papuga, M Owen; Burke, Jeanmarie R

    2011-02-01

    An ink pad and paper, pressure-sensitive platforms, and photography have previously been used to collect footprint data used in clinical assessment. Digital scanners have been widely used more recently to collect such data. The purpose of this study was to evaluate the intra- and interrater reliability of a flatbed digital image scanning technology to capture footprint data. This study used a repeated-measures design on 32 (16 male 16 female) healthy subjects. The following measured indices of footprint were recorded from 2-dimensional images of the plantar surface of the foot recorded with an Associate Platinum (Foot Levelers Inc, Roanoke, VA) digital foot scanner: Staheli index, Chippaux-Smirak index, arch angle, and arch index. Intraclass correlation coefficient (ICC) values were calculated to evaluate intrarater, interday, and interclinician reliability. The ICC values for intrarater reliability were greater than or equal to .817, indicating an excellent level of reproducibility in assessing the collected images. Analyses of variance revealed that there were no significant differences between raters for each index (P > .05). The ICC values also indicated excellent reliability (.881-.971) between days and clinicians in all but one of the indices of footprint, arch angle (.689), with good reliability between clinicians. The full-factorial analysis of variance model did not reveal any interaction effects (P > .05), which indicated that indices of footprint were not changing across days and clinicians. Scanning technology used in this study demonstrated good intra- and interrater reliability measurements of footprint indices, as demonstrated by high ICC values. Copyright © 2011 National University of Health Sciences. Published by Mosby, Inc. All rights reserved.

  9. A three-frame digital image correlation (DIC) method for the measurement of small displacements and strains

    International Nuclear Information System (INIS)

    Cofaru, C; Philips, W; Van Paepegem, W

    2012-01-01

    Digital image correlation (DIC) has become a well-established approach for the calculation of full-field displacement and strains within the field of experimental mechanics. Since their introduction, DIC methods have been relying on only two images to measure the displacements and strains that materials undergo under load. It can be foreseen that the use of additional image information for the calculus of displacements and strains, although computationally more expensive, can positively impact DIC method accuracy under both ideal and challenging experimental conditions. Such accuracy improvements are especially important when measuring very small deformations, which still constitutes a great challenge: small displacements and strains translate into equally small digital image intensity changes on the material’s surface, which are affected by the digitization processes of the imaging hardware and by other image acquisition effects such as image noise. This paper proposes a new three-frame Newton–Raphson DIC method and evaluates it from the standpoints of accuracy and speed. The method models the deformations that are to be measured under the assumption that the deformation occurs at approximately the same rate between each two consecutive images in the three image sequences that are employed. The aim is to investigate how the use of image data from more than two images impacts accuracy and what is the effect on the computational speed. The proposed method is compared with the classic two-frame Newton–Raphson method in three experiments. Two experiments rely on numerically deformed images that simulate heterogeneous deformations. The third experiment uses images from a real deformation experiment. Results indicate that although it is computationally more demanding, the three-frame method significantly improves displacement and strain accuracy and is less sensitive to image noise. (paper)

  10. Identifying the candidate genes involved in the calyx abscission process of 'Kuerlexiangli' (Pyrus sinkiangensis Yu) by digital transcript abundance measurements.

    Science.gov (United States)

    Qi, Xiaoxiao; Wu, Jun; Wang, Lifen; Li, Leiting; Cao, Yufen; Tian, Luming; Dong, Xingguang; Zhang, Shaoling

    2013-10-23

    'Kuerlexiangli' (Pyrus sinkiangensis Yu), a native pear of Xinjiang, China, is an important agricultural fruit and primary export to the international market. However, fruit with persistent calyxes affect fruit shape and quality. Although several studies have looked into the physiological aspects of the calyx abscission process, the underlying molecular mechanisms remain unknown. In order to better understand the molecular basis of the process of calyx abscission, materials at three critical stages of regulation, with 6000 × Flusilazole plus 300 × PBO treatment (calyx abscising treatment) and 50 mg.L-1GA3 treatment (calyx persisting treatment), were collected and cDNA fragments were sequenced using digital transcript abundance measurements to identify candidate genes. Digital transcript abundance measurements was performed using high-throughput Illumina GAII sequencing on seven samples that were collected at three important stages of the calyx abscission process with chemical agent treatments promoting calyx abscission and persistence. Altogether more than 251,123,845 high quality reads were obtained with approximately 8.0 M raw data for each library. The values of 69.85%-71.90% of clean data in the digital transcript abundance measurements could be mapped to the pear genome database. There were 12,054 differentially expressed genes having Gene Ontology (GO) terms and associating with 251 Kyoto Encyclopedia of Genes and Genomes (KEGG) defined pathways. The differentially expressed genes correlated with calyx abscission were mainly involved in photosynthesis, plant hormone signal transduction, cell wall modification, transcriptional regulation, and carbohydrate metabolism. Furthermore, candidate calyx abscission-specific genes, e.g. Inflorescence deficient in abscission gene, were identified. Quantitative real-time PCR was used to confirm the digital transcript abundance measurements results. We identified candidate genes that showed highly dynamic changes in

  11. Electrocardiograms digitally processed for the investigation of new measures of cardiac diagnosis

    International Nuclear Information System (INIS)

    Gutierrez, Rafael M; Cerquera, Alexander

    2003-01-01

    The ECG F D 1 database that comprises electrocardiograms processed with digital filters is presented. The aim of this work is to build databases in order to perform high sensibility studies of new methods for electrocardiographic analysis based on statistical physics, actually on research. The changes in the original electrocardiograms generated by the digital filters used to build the ECG F D 1 database cannot be detected visually. The effect of these filters on the information, which escapes visual analysis, is actually object of study in order to develop its potential in the support of cardiac diagnosis using the electrocardiogram as the only source of information. The ECG F D 1 database may be very useful in the investigation directed to construct new diagnostic tools in cardiology, using simpler and less expensive electrocardiograms, obtained in more diverse conditions. the study of cardiac dynamics as a complex system starting from a source of information as simple as an electrocardiogram offers possibilities of creating new services that may improve the quality of human life and life expectancy at low costs and possibility of great coverage. One of the purposes of this publication is to draw the scientific community's attention to these investigative problems and its interdisciplinary applications

  12. Measurement of the Diffusion Coefficient of Water in RP-3 and RP-5 Jet Fuels Using Digital Holography Interferometry

    Science.gov (United States)

    Li, Chaoyue; Feng, Shiyu; Shao, Lei; Pan, Jun; Liu, Weihua

    2018-04-01

    The diffusion coefficient of water in jet fuel was measured employing double-exposure digital holographic interferometry to clarify the diffusion process and make the aircraft fuel system safe. The experimental method and apparatus are introduced in detail, and the digital image processing program is coded in MATLAB according to the theory of the Fourier transform. At temperatures ranging from 278.15 K to 333.15 K in intervals of 5 K, the diffusion coefficient of water in RP-3 and RP-5 jet fuels ranges from 2.6967 × 10 -10 m2·s-1 to 8.7332 × 10 -10 m2·s-1 and from 2.3517 × 10 -10 m2·s-1 to 8.0099 × 10-10 m2·s-1, respectively. The relationship between the measured diffusion coefficient and temperature can be well fitted by the Arrhenius law. The diffusion coefficient of water in RP-3 jet fuel is higher than that of water in RP-5 jet fuel at the same temperature. Furthermore, the viscosities of the two jet fuels were measured and found to be expressible in the form of the Arrhenius equation. The relationship among the diffusion coefficient, viscosity and temperature is analyzed according to the classic prediction model, namely the Stokes-Einstein correlation, and this correlation is further revised via experimental data to obtain a more accurate predication result.

  13. Pulsed TV holography measurement and digital reconstruction of compression acoustic wave fields: application to nondestructive testing of thick metallic samples

    International Nuclear Information System (INIS)

    Trillo, C; Doval, A F; Deán-Ben, X L; López-Vázquez, J C; Fernández, J L; Hernández-Montes, S

    2011-01-01

    This paper describes a technique that numerically reconstructs the complex acoustic amplitude (i.e. the acoustic amplitude and phase) of a compression acoustic wave in the interior volume of a specimen from a set of full-field optical measurements of the instantaneous displacement of the surface. The volume of a thick specimen is probed in transmission mode by short bursts of narrowband compression acoustic waves generated at one of its faces. The temporal evolution of the displacement field induced by the bursts emerging at the opposite surface is measured by pulsed digital holographic interferometry (pulsed TV holography). A spatio-temporal 3D Fourier transform processing of the measured data yields the complex acoustic amplitude at the plane of the surface as a sequence of 2D complex-valued maps. Finally, a numerical implementation of the Rayleigh–Sommerfeld diffraction formula is employed to reconstruct the complex acoustic amplitude at other planes in the interior volume of the specimen. The whole procedure can be regarded as a combination of optical digital holography and acoustical holography methods. The technique was successfully tested on aluminium specimens with and without an internal artificial defect and sample results are presented. In particular, information about the shape and position of the defect was retrieved in the experiment performed on the flawed specimen, which indicates the potential applicability of the technique for the nondestructive testing of materials

  14. A new ball-on-disk vacuum tribometer with in situ measurement of the wear track by digital holographic microscopy

    Science.gov (United States)

    Meylan, B.; Ciani, D.; Zhang, B.; Cuche, E.; Wasmer, K.

    2017-12-01

    This contribution presents a new ball-on-disk vacuum tribometer with in situ measurement of the wear track by digital holographic microscopy. This new tribometer allows observation of the evolution of the wear track in situ and in real-time. The method combines a high vacuum high temperature ball-on-disk tribometer with a digital holographic microscope (DHM). The machine was tested and validated by taking DHM images during wear tests at room temperature and in vacuum at 2 · 10-6 of polished 100Cr6 steel disks. We demonstrated that the DHM system is well suited to monitor the evolution of the wear track during sliding. We found that, with an acquisition time of 0.1 ms for the DHM, the maximal linear speed is 10 cm s-1 to have reliable images. We proved, via scanning electron microscope (SEM) pictures, that the lines in the sliding direction in all DHM images exist. We also validated the new tribometer by having an excellent correlation between the images and profiles of the wear track taken by the DHM with the ones from a confocal microscope. Finally, the new tribometer combined with the DHM has four advantages. It can test under vacuum and various atmospheric conditions. The evolution of the wear track is measured in situ and in real-time. Hence, the problem of replacing the sample is avoided. Thanks to the DHM technology, the vertical accuracy of the topographical measurement is 4 nm.

  15. Achondroplasia Associated with Bilateral Keratoconus

    Directory of Open Access Journals (Sweden)

    Ammar M. Al Mahmood

    2012-01-01

    Full Text Available We report a rare case of bilateral keratoconus in association with achondroplasia. A 26-year-old male, with a known case of achondroplasia, complained of bilateral gradual deterioration in vision for the past few years. Slit lamp biomicroscopy showed bilateral central corneal protrusion and stromal thinning at the apex consistent with keratoconus. a trial of hard contact lens fitting failed to improve VA in the left eye (LE. Right eye (RE improved to 20/25. The patient underwent penetrating keratoplasty (PKP in his LE. Twenty-seven months postoperatively, uncorrected visual acuity (UCVA was 20/30. Ophthalmologists should be aware that patients with achondroplasia who complain of poor vision should be suspected of having keratoconus once other more common conditions are ruled out.

  16. Multilateral, regional and bilateral energy trade governance

    Energy Technology Data Exchange (ETDEWEB)

    Leal-Arcas, Rafael; Grasso, Costantino; Rios, Juan Alemany (Queen Mary Univ. of London (United Kingdom))

    2014-12-01

    The current international energy trade governance system is fragmented and multi-layered. Streamlining it for greater legal cohesiveness and international political and economic cooperation would promote global energy security. The current article explores three levels of energy trade governance: multilateral, regional and bilateral. Most energy-rich countries are part of the multilateral trading system, which is institutionalized by the World Trade Organization (WTO). The article analyzes the multilateral energy trade governance system by focusing on the WTO and energy transportation issues. Regionally, the article focuses on five major regional agreements and their energy-related aspects and examines the various causes that explain the proliferation of regional trade agreements, their compatibility with WTO law, and then provides several examples of regional energy trade governance throughout the world. When it comes to bilateral energy trade governance, this article only addresses the European Union’s (EU) bilateral energy trade relations. The article explores ways in which gaps could be filled and overlaps eliminated whilst remaining true to the high-level normative framework, concentrating on those measures that would enhance EU energy security.

  17. Bilateral ovarian fibroma associated with Gorlin syndrome

    Directory of Open Access Journals (Sweden)

    Shahnaz Aram

    2009-02-01

    Full Text Available

    • Gorlin syndrome (GS, also known as nevoid basal cell carcinoma syndrome (NBCCS, is a rare inherited multisystem disorder. This paper presents a 22-years-old Iranian woman with this syndrome whose past history was multiple keratocysts of maxillary bone. She was referred to gynecology clinic with the chief complaint of irregular menses and vaginal spotting. On examination, frontal bossing and hypertelorism were detected. Physical examination of genitalia disclosed bilateral adnexal masses. Pelvic ultrasound showed two solid, echogenous and calcified masses measuring 100*50*10 & 60*50*45 mm in the left and right ovaries, respectively. The patient underwent right oophorectomy and ovarian mass resection with preservation of intact ovarian tissue on the left side. On frozen and permanent histological sections, bilateral and calcified ovarian fibromas were diagnosed. Surprisingly, during the last follow-up one year after the surgery, we found that our patient was expecting a baby. It can be concluded that in the presence of bilateral and calcified ovarian fibromas, the possibility of GS should be considered. Accurate diagnosis is only possible with close attention to the familial and past medical history and physical examination. In these patients, careful follow up for detecting malignancies and other complications is highly recommended.
    • KEY WORDS: Gorlin syndrome, ovarian fibroma, multiple keratocysts.

  18. Absolute distance measurement by dual-comb interferometry with multi-channel digital lock-in phase detection

    International Nuclear Information System (INIS)

    Yang, Ruitao; Pollinger, Florian; Meiners-Hagen, Karl; Krystek, Michael; Bosse, Harald; Tan, Jiubin

    2015-01-01

    We present a dual-comb-based heterodyne multi-wavelength absolute interferometer capable of long distance measurements. The phase information of the various comb modes is extracted in parallel by a multi-channel digital lock-in phase detection scheme. Several synthetic wavelengths of the same order are constructed and the corresponding phases are averaged to deduce the absolute lengths with significantly reduced uncertainty. Comparison experiments with an incremental HeNe reference interferometer show a combined relative measurement uncertainty of 5.3 × 10 −7 at a measurement distance of 20 m. Combining the advantage of synthetic wavelength interferometry and dual-comb interferometry, our compact and simple approach provides sufficient precision for many industrial applications. (paper)

  19. Absolute distance measurement by dual-comb interferometry with multi-channel digital lock-in phase detection

    Science.gov (United States)

    Yang, Ruitao; Pollinger, Florian; Meiners-Hagen, Karl; Krystek, Michael; Tan, Jiubin; Bosse, Harald

    2015-08-01

    We present a dual-comb-based heterodyne multi-wavelength absolute interferometer capable of long distance measurements. The phase information of the various comb modes is extracted in parallel by a multi-channel digital lock-in phase detection scheme. Several synthetic wavelengths of the same order are constructed and the corresponding phases are averaged to deduce the absolute lengths with significantly reduced uncertainty. Comparison experiments with an incremental HeNe reference interferometer show a combined relative measurement uncertainty of 5.3 × 10-7 at a measurement distance of 20 m. Combining the advantage of synthetic wavelength interferometry and dual-comb interferometry, our compact and simple approach provides sufficient precision for many industrial applications.

  20. In-situ measurement of the strain distribution in a tensile specimen by using a digital speckle pattern interferometer

    International Nuclear Information System (INIS)

    Park, Seung-Kyu; Baik, Sung-Hoon; Cha, Hyung-Ki; Kim, Young-Suk; Cheong, Yong-Moo

    2010-01-01

    Less sensitivity to environmental vibrations is essential for industrial applications of a digital speckle pattern interferometer (DSPI) to measure micro deformations. In this paper, a robust DSPI using single fringe to mechanical vibrations is designed for measuring the strain distribution of a tensile specimen. This system adopts a noise-immune signal processing algorithm to acquire a 3D strain distribution image. To acquire an accurate strain distribution for a tensile-specimen, locally-averaged and directionally-oriented filters operating in the frequency domain are used. This system uses a path-independent least-squares phase-unwrapping algorithm to acquire the 3D shape of the strain distribution. As for the initial experiments to measure the strain distribution of a tensile specimen in a vibration field, this system demonstrated a feasibility for industrial applications by providing reliable strain data.

  1. Validation of Shape Context Based Image Registration Method Using Digital Image Correlation Measurement on a Rat Stomach

    DEFF Research Database (Denmark)

    Liao, Donghua; Wang, P; Zhao, Jingbo

    2014-01-01

    Recently we developed analysis for 3D visceral organ deformation by combining the shape context (SC) method with a full-field strain (strain distribution on a whole 3D surface) analysis for calculating distension-induced rat stomach deformation. The surface deformation detected by the SC method...... needs to be further verified by using a feature tracking measurement. Hence, the aim of this study was to verify the SC method-based calculation by using digital image correlation (DIC) measurement on a rat stomach. The rat stomach exposed to distension pressures 0.0, 0.2, 0.4, and 0.6 kPa were studied...... and the SC calculated correspondence surface was compared. Compared with DIC measurement, the SC calculated surface had errors from 5% to 23% at pressures from 0.2 to 0.6 kPa with different surface sample counts between the reference surface and the target surface. This indicates good qualitative...

  2. Simultaneous bilateral patellar tendon rupture.

    Science.gov (United States)

    Moura, Diogo Lino; Marques, José Pedro; Lucas, Francisco Manuel; Fonseca, Fernando Pereira

    2017-01-01

    Bilateral patellar tendon rupture is a rare entity, often associated with systemic diseases and patellar tendinopathy. The authors report a rare case of a 34-year-old man with simultaneous bilateral rupture of the patellar tendon caused by minor trauma. The patient is a retired basketball player with no past complaints of chronic knee pain and a history of steroid use. Surgical management consisted in primary end-to-end tendon repair protected temporarily with cerclage wiring, followed by a short immobilization period and intensive rehabilitation program. Five months after surgery, the patient was able to fully participate in sport activities.

  3. Simultaneous bilateral patellar tendon rupture

    Directory of Open Access Journals (Sweden)

    Diogo Lino Moura

    Full Text Available ABSTRACT Bilateral patellar tendon rupture is a rare entity, often associated with systemic diseases and patellar tendinopathy. The authors report a rare case of a 34-year-old man with simultaneous bilateral rupture of the patellar tendon caused by minor trauma. The patient is a retired basketball player with no past complaints of chronic knee pain and a history of steroid use. Surgical management consisted in primary end-to-end tendon repair protected temporarily with cerclage wiring, followed by a short immobilization period and intensive rehabilitation program. Five months after surgery, the patient was able to fully participate in sport activities.

  4. Digital broadcasting

    International Nuclear Information System (INIS)

    Park, Ji Hyeong

    1999-06-01

    This book contains twelve chapters, which deals with digitization of broadcast signal such as digital open, digitization of video signal and sound signal digitization of broadcasting equipment like DTPP and digital VTR, digitization of equipment to transmit such as digital STL, digital FPU and digital SNG, digitization of transmit about digital TV transmit and radio transmit, digital broadcasting system on necessity and advantage, digital broadcasting system abroad and Korea, digital broadcasting of outline, advantage of digital TV, ripple effect of digital broadcasting and consideration of digital broadcasting, ground wave digital broadcasting of DVB-T in Europe DTV in U.S.A and ISDB-T in Japan, HDTV broadcasting, satellite broadcasting, digital TV broadcasting in Korea, digital radio broadcasting and new broadcasting service.

  5. [Computer-assisted measurement of ocular misalignment in infants and young children using the digital Purkinje reflection pattern procedure].

    Science.gov (United States)

    Barry, J C; Effert, R; Kaupp, A; Kleine, M; Reim, M

    1994-02-01

    A digital image recording and processing system is presented that allows a quick diagnosis of microstrabismus in non-cooperative children. It is thus particularly suited for screening purposes. The Purkinje Reflection Pattern Evaluation (RPE) method is used: three small flashes are used to produce the desired Purkinje images. Two horizontal rows of the three 1st Purkinje images (anterior corneal reflections) and of the three 4th Purkinje images (posterior crystalline lens reflections) stemming from the three light sources form the characteristic Purkinje image reflection pattern. Each eye's position is calculated from the shift between the upper and lower rows of reflections by means of two simple formulae. From the angles obtained in binocular fixation and monocular fixation the manifest angle of strabismus corresponding to the angle measured in the simultaneous prism-and-cover test is computed. The measurement is performed at a fixation distance of 50 cm under natural viewing conditions. To obtain a picture one only has to get the child's attention for a short moment. The primary position is triggered with the fixation light, which is operated by a switch. The digital image recording is done with a hand-held device comprising two miniaturized video cameras, three photo flashes and a fixation light that is operated manually. An IBM-compatible PC equipped with a hard disk and two frame grabbers was adapted for the storage and processing of the pictures. The pictures are evaluated interactively in a few minutes on the workstation's monitor immediately after the measurement. To this end specially designed menu-driven software was implemented. Examples of the measuring procedure and clinical results in infants with microtropic highlight the potential of the system as a screening apparatus and for the exact measurement of small and large squint angles. Usually even 1-year-old children can cooperate well enough to get good-quality pictures in binocular fixation. The new

  6. DIGITAL IMAGE CORRELATION FROM COMMERCIAL TO FOS SOFTWARE: A MATURE TECHNIQUE FOR FULL-FIELD DISPLACEMENT MEASUREMENTS

    Directory of Open Access Journals (Sweden)

    V. Belloni

    2018-05-01

    Full Text Available In the last few decades, there has been a growing interest in studying non-contact methods for full-field displacement and strain measurement. Among such techniques, Digital Image Correlation (DIC has received particular attention, thanks to its ability to provide these information by comparing digital images of a sample surface before and after deformation. The method is now commonly adopted in the field of civil, mechanical and aerospace engineering and different companies and some research groups implemented 2D and 3D DIC software. In this work a review on DIC software status is given at first. Moreover, a free and open source 2D DIC software is presented, named py2DIC and developed in Python at the Geodesy and Geomatics Division of DICEA of the University of Rome “La Sapienza”; its potentialities were evaluated by processing the images captured during tensile tests performed in the Structural Engineering Lab of the University of Rome “La Sapienza” and comparing them to those obtained using the commercial software Vic-2D developed by Correlated Solutions Inc, USA. The agreement of these results at one hundredth of millimetre level demonstrate the possibility to use this open source software as a valuable 2D DIC tool to measure full-field displacements on the investigated sample surface.

  7. Full-field vibration measurements of the violin using digital stroboscopic holographic interferometry and electromagnetic stimulation of the strings

    Science.gov (United States)

    Keersmaekers, Lissa; Keustermans, William; De Greef, Daniël; Dirckx, Joris J. J.

    2016-06-01

    We developed a setup in which the strings of the violin are driven electromagnetically, and the resulting vibration of the instrument is measured with digital stroboscopic holography. A 250mW single mode green laser beam is chopped using an acousto-optic modulator, generating illumination pulses of 2% of the vibration period. The phase of the illumination pulse is controlled by a programmable function generator so that digital holograms can be recorded on a number of subsequent time positions within the vibration phase. From these recordings, the out of plane motion as a function of time is reconstructed in full field. We show results of full-field vibration amplitude and vibration phase maps, and time resolved full-field deformations of the violin back plane. Time resolved measurements show in detail how the deformation of the violin plane changes as a function of time at different frequencies. We found very different behavior under acoustic stimulation of the instrument and when using electromagnetic stimulation of a string. The aim of the work it to gather data which can be used in power flow calculations to study how the energy of the strings is conducted to the body of the violin and eventually is radiated as sound.

  8. Full-field vibration measurements of the violin using digital stroboscopic holographic interferometry and electromagnetic stimulation of the strings

    International Nuclear Information System (INIS)

    Keersmaekers, Lissa; Keustermans, William; De Greef, Daniël; Dirckx, Joris J. J.

    2016-01-01

    We developed a setup in which the strings of the violin are driven electromagnetically, and the resulting vibration of the instrument is measured with digital stroboscopic holography. A 250 mW single mode green laser beam is chopped using an acousto-optic modulator, generating illumination pulses of 2% of the vibration period. The phase of the illumination pulse is controlled by a programmable function generator so that digital holograms can be recorded on a number of subsequent time positions within the vibration phase. From these recordings, the out of plane motion as a function of time is reconstructed in full field. We show results of full-field vibration amplitude and vibration phase maps, and time resolved full-field deformations of the violin back plane. Time resolved measurements show in detail how the deformation of the violin plane changes as a function of time at different frequencies. We found very different behavior under acoustic stimulation of the instrument and when using electromagnetic stimulation of a string. The aim of the work it to gather data which can be used in power flow calculations to study how the energy of the strings is conducted to the body of the violin and eventually is radiated as sound.

  9. Full-field vibration measurements of the violin using digital stroboscopic holographic interferometry and electromagnetic stimulation of the strings

    Energy Technology Data Exchange (ETDEWEB)

    Keersmaekers, Lissa; Keustermans, William, E-mail: william.keustermans@uantwerpen.be; De Greef, Daniël; Dirckx, Joris J. J. [University of Antwerp, Laboratory of Biophysics and Biomedical Physics, Groenenborgerlaan 171, 2020 Antwerp (Belgium)

    2016-06-28

    We developed a setup in which the strings of the violin are driven electromagnetically, and the resulting vibration of the instrument is measured with digital stroboscopic holography. A 250 mW single mode green laser beam is chopped using an acousto-optic modulator, generating illumination pulses of 2% of the vibration period. The phase of the illumination pulse is controlled by a programmable function generator so that digital holograms can be recorded on a number of subsequent time positions within the vibration phase. From these recordings, the out of plane motion as a function of time is reconstructed in full field. We show results of full-field vibration amplitude and vibration phase maps, and time resolved full-field deformations of the violin back plane. Time resolved measurements show in detail how the deformation of the violin plane changes as a function of time at different frequencies. We found very different behavior under acoustic stimulation of the instrument and when using electromagnetic stimulation of a string. The aim of the work it to gather data which can be used in power flow calculations to study how the energy of the strings is conducted to the body of the violin and eventually is radiated as sound.

  10. Portable digital lock-in instrument to determine chemical constituents with single-color absorption measurements for Global Health Initiatives

    Science.gov (United States)

    Vacas-Jacques, Paulino; Linnes, Jacqueline; Young, Anna; Gerrard, Victoria; Gomez-Marquez, Jose

    2014-03-01

    Innovations in international health require the use of state-of-the-art technology to enable clinical chemistry for diagnostics of bodily fluids. We propose the implementation of a portable and affordable lock-in amplifier-based instrument that employs digital technology to perform biochemical diagnostics on blood, urine, and other fluids. The digital instrument is composed of light source and optoelectronic sensor, lock-in detection electronics, microcontroller unit, and user interface components working with either power supply or batteries. The instrument performs lock-in detection provided that three conditions are met. First, the optoelectronic signal of interest needs be encoded in the envelope of an amplitude-modulated waveform. Second, the reference signal required in the demodulation channel has to be frequency and phase locked with respect to the optoelectronic carrier signal. Third, the reference signal should be conditioned appropriately. We present three approaches to condition the signal appropriately: high-pass filtering the reference signal, precise offset tuning the reference level by low-pass filtering, and by using a voltage divider network. We assess the performance of the lock-in instrument by comparing it to a benchmark device and by determining protein concentration with single-color absorption measurements. We validate the concentration values obtained with the proposed instrument using chemical concentration measurements. Finally, we demonstrate that accurate retrieval of phase information can be achieved by using the same instrument.

  11. Portable digital lock-in instrument to determine chemical constituents with single-color absorption measurements for Global Health Initiatives

    Energy Technology Data Exchange (ETDEWEB)

    Vacas-Jacques, Paulino [Little Devices Group, SUTD-MIT International Design Center, Cambridge, Massachusetts 02139 (United States); Wellman Center for Photomedicine and Harvard Medical School, Massachusetts General Hospital, Boston, Massachusetts 02114 (United States); Linnes, Jacqueline [Little Devices Group, SUTD-MIT International Design Center, Cambridge, Massachusetts 02139 (United States); Biomedical Engineering Department, Boston University, Boston, Massachusetts 02215 (United States); Young, Anna; Gomez-Marquez, Jose [Little Devices Group, SUTD-MIT International Design Center, Cambridge, Massachusetts 02139 (United States); Gerrard, Victoria [Little Devices Group, SUTD-MIT International Design Center, Cambridge, Massachusetts 02139 (United States); Opportunity Lab, Singapore University for Technology and Design, Singapore 138682 (Singapore)

    2014-03-15

    Innovations in international health require the use of state-of-the-art technology to enable clinical chemistry for diagnostics of bodily fluids. We propose the implementation of a portable and affordable lock-in amplifier-based instrument that employs digital technology to perform biochemical diagnostics on blood, urine, and other fluids. The digital instrument is composed of light source and optoelectronic sensor, lock-in detection electronics, microcontroller unit, and user interface components working with either power supply or batteries. The instrument performs lock-in detection provided that three conditions are met. First, the optoelectronic signal of interest needs be encoded in the envelope of an amplitude-modulated waveform. Second, the reference signal required in the demodulation channel has to be frequency and phase locked with respect to the optoelectronic carrier signal. Third, the reference signal should be conditioned appropriately. We present three approaches to condition the signal appropriately: high-pass filtering the reference signal, precise offset tuning the reference level by low-pass filtering, and by using a voltage divider network. We assess the performance of the lock-in instrument by comparing it to a benchmark device and by determining protein concentration with single-color absorption measurements. We validate the concentration values obtained with the proposed instrument using chemical concentration measurements. Finally, we demonstrate that accurate retrieval of phase information can be achieved by using the same instrument.

  12. Parasternal lymphoscintigraphy using the bilateral collimator

    International Nuclear Information System (INIS)

    Ohtake, Eiji; Iio, Masahiro; Toyama, Hinako; Kawaguchi, Shinichiro; Murata, Hajime

    1981-01-01

    A new method for measuring the depth of the parasternal lymph node was studied. The bilateral collimator used in this study consisted of two arrays of parallel holes which were slanted at +-30 degrees, respectively, to the vertical line. When the collimator was set to image the object in both sides of the field, the object and the dual images formed a regular triangle. The distance (D) from the image (crystal) plane to the object can be expressed by the equation: D = 1/2.L.cot30 0 = 0.866.L where L is the interval between the dual images calibrated to the real length. The distance from the collimator surface to the object is obtained by subtracting the effective thickness (T) between the image plane and the collimator surface from D. T was experimentally measured by the above equation, placing point sources on the collimator surface. The principle was applied to measure the depth of the parasternal lymph node. The parasternal lymphoscintigram was obtained four hours after bilateral subcostal injection of sup(99m)Tc-sulfur colloid and the image was taken by a Searle Pho/Gamma LFOV camera equipped with the bilateral collimator. When the scintigraphic image was made, radioactive markers were placed at the body surface to measure the distance from the collimator surface to the body surface Nineteen patients were examined. As a result, the lymph nodes were found to be located in the depths ranging widely from 0.4 to 6.5 cm from the anterior surface of the chest wall. These lymph nodes were thought to contain the deeply seated mediastinal nodes, and the superficial nodes located directly beneath the skin. Model studies were also performed to estimate the accuracy of this method and satisfactory results were obtained. (author)

  13. Bilateral tension pneumothorax after acupuncture.

    Science.gov (United States)

    Mohammad, Nurashikin

    2018-04-19

    Acupuncture is an ancient complementary medicine which is currently used worldwide. Many serious adverse events have been reported which include a spectrum of mild-to-fatal complications. However, the level of awareness with regard to complications is still low both to physicians and patients. We report a 63-year-old who presented with acute shortness of breath 2 hours after having had acupuncture. On examination, there was absent breath sound heard on the left lung and slightly reduced breath sound on the right lung. She had type 1 respiratory failure. Urgent chest radiograph confirmed bilateral pneumothorax which was more severe on the left with tension pneumothorax and mediastinal shift. Chest tubes were inserted bilaterally after failed needle aspiration attempts. Subsequently, the pneumothoraces resolved, and she was discharged well. The bilateral pneumothoraces caused by acupuncture were curable but could have been potentially fatal if diagnosis was delayed. This case report adds to the limited current literature on the complications of acupuncture leading to bilateral pneumothoraces. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  14. Bilateral breast in brothers - abreast

    Directory of Open Access Journals (Sweden)

    Altamash Mohammed Yusuf Shaikh

    2013-01-01

    Full Text Available Gynecomastia is a common occurrence in pubertal age group, and is physiological in up to 65 percent of cases. When occurs in the family it should be investigated in order not to miss on a treatable etiology. Two brothers within the same family, presenting with bilateral gynecomastia of different causes and requiring different treatment are presented.

  15. A study on fast digital discrimination of neutron and gamma-ray for improvement neutron emission profile measurement

    International Nuclear Information System (INIS)

    Uchida, Y.; Takada, E.; Fujisaki, A.; Isobe, M.; Ogawa, K.; Shinohara, K.; Tomita, H.; Kawarabayashi, J.; Iguchi, T.

    2014-01-01

    Neutron and γ-ray (n-γ) discrimination with a digital signal processing system has been used to measure the neutron emission profile in magnetic confinement fusion devices. However, a sampling rate must be set low to extend the measurement time because the memory storage is limited. Time jitter decreases a discrimination quality due to a low sampling rate. As described in this paper, a new charge comparison method was developed. Furthermore, automatic n-γ discrimination method was examined using a probabilistic approach. Analysis results were investigated using the figure of merit. Results show that the discrimination quality was improved. Automatic discrimination was applied using the EM algorithm and k-means algorithm

  16. A study on fast digital discrimination of neutron and gamma-ray for improvement neutron emission profile measurement

    Energy Technology Data Exchange (ETDEWEB)

    Uchida, Y., E-mail: h1312101@mailg.nc-toyama.ac.jp; Takada, E.; Fujisaki, A. [National Institute of Technology, Toyama College, 13 Hongo-machi, Toyama 939-8630 (Japan); Isobe, M. [National Institute for Fusion Science, 322-6 Oroshi-cho, Toki 509-5292 (Japan); The Graduate University for Advanced Studies (SOKENDAI), 322-6 Oroshi-cho, Toki 509-5292 (Japan); Ogawa, K. [National Institute for Fusion Science, 322-6 Oroshi-cho, Toki 509-5292 (Japan); Shinohara, K. [Japan Atomic Energy Agency, 801-1 Mukoyama, Naka 311-0913 (Japan); Tomita, H.; Kawarabayashi, J.; Iguchi, T. [Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8603 (Japan)

    2014-11-15

    Neutron and γ-ray (n-γ) discrimination with a digital signal processing system has been used to measure the neutron emission profile in magnetic confinement fusion devices. However, a sampling rate must be set low to extend the measurement time because the memory storage is limited. Time jitter decreases a discrimination quality due to a low sampling rate. As described in this paper, a new charge comparison method was developed. Furthermore, automatic n-γ discrimination method was examined using a probabilistic approach. Analysis results were investigated using the figure of merit. Results show that the discrimination quality was improved. Automatic discrimination was applied using the EM algorithm and k-means algorithm.

  17. Short-coherence in-line phase-shifting infrared digital holographic microscopy for measurement of internal structure in silicon

    Science.gov (United States)

    Xi, Teli; Dou, Jiazhen; Di, Jianglei; Li, Ying; Zhang, Jiwei; Ma, Chaojie; Zhao, Jianlin

    2017-06-01

    Short-coherence in-line phase-shifting digital holographic microscopy based on Michelson interferometer is proposed to measure internal structure in silicon. In the configuration, a short-coherence infrared laser is used as the light source in order to avoid the interference formed by the reference wave and the reflected wave from the front surface of specimen. At the same time, in-line phase-shifting configuration is introduced to overcome the problem of poor resolution and large pixel size of the infrared camera and improve the space bandwidth product of the system. A specimen with staircase structure is measured by using the proposed configuration and the 3D shape distribution are given to verify the effectiveness and accuracy of the method.

  18. Using grey intensity adjustment strategy to enhance the measurement accuracy of digital image correlation considering the effect of intensity saturation

    Science.gov (United States)

    Li, Bang-Jian; Wang, Quan-Bao; Duan, Deng-Ping; Chen, Ji-An

    2018-05-01

    Intensity saturation can cause decorrelation phenomenon and decrease the measurement accuracy in digital image correlation (DIC). In the paper, the grey intensity adjustment strategy is proposed to improve the measurement accuracy of DIC considering the effect of intensity saturation. First, the grey intensity adjustment strategy is described in detail, which can recover the truncated grey intensities of the saturated pixels and reduce the decorrelation phenomenon. The simulated speckle patterns are then employed to demonstrate the efficacy of the proposed strategy, which indicates that the displacement accuracy can be improved by about 40% by the proposed strategy. Finally, the true experimental image is used to show the feasibility of the proposed strategy, which indicates that the displacement accuracy can be increased by about 10% by the proposed strategy.

  19. Nitrosylated hemoglobin levels in human venous erythrocytes correlate with vascular endothelial function measured by digital reactive hyperemia.

    Directory of Open Access Journals (Sweden)

    Irina I Lobysheva

    Full Text Available Impaired nitric oxide (NO-dependent endothelial function is associated with the development of cardiovascular diseases. We hypothesized that erythrocyte levels of nitrosylated hemoglobin (HbNO-heme may reflect vascular endothelial function in vivo. We developed a modified subtraction method using Electron Paramagnetic Resonance (EPR spectroscopy to identify the 5-coordinate α-HbNO (HbNO concentration in human erythrocytes and examined its correlation with endothelial function assessed by peripheral arterial tonometry (PAT. Changes in digital pulse amplitude were measured by PAT during reactive hyperemia following brachial arterial occlusion in a group of healthy volunteers (50 subjects. Erythrocyte HbNO levels were measured at baseline and at the peak of hyperemia. We digitally subtracted an individual model EPR signal of erythrocyte free radicals from the whole EPR spectrum to unmask and quantitate the HbNO EPR signals.Mean erythrocyte HbNO concentration at baseline was 219+/-12 nmol/L (n = 50. HbNO levels and reactive hyperemia (RH indexes were higher in female (free of contraceptive pills than male subjects. We observed a dynamic increase of HbNO levels in erythrocytes isolated at 1-2 min of post-occlusion hyperemia (120+/-8% of basal levels; post-occlusion HbNO levels were correlated with basal levels. Both basal and post-occlusion HbNO levels were significantly correlated with reactive hyperemia (RH indexes (r = 0.58; P<0.0001 for basal HbNO.The study demonstrates quantitative measurements of 5-coordinate α-HbNO in human venous erythrocytes, its dynamic physiologic regulation and correlation with endothelial function measured by tonometry during hyperemia. This opens the way to further understanding of in vivo determinants of NO bioavailability in human circulation.

  20. Digitally controlled measurement of sonic elastic moduli and internal friction by phase analysis

    International Nuclear Information System (INIS)

    O'Brien, M.H.; Hunter, O. Jr.; Rasmussen, M.D.; Skank, H.D.

    1983-01-01

    An automated system is described for measuring internal friction and elastic moduli using sonic resonance techniques. This mirocomputer-controlled device does phase angle analysis in addition to traditional decay and peak-width internal friction measurement. The apparatus may be programmed to make measurements at any sequence of temperatures between room temperature and 1600 0 C

  1. Implementation of a high precision multi-measurement time-to-digital convertor on a Kintex-7 FPGA

    Science.gov (United States)

    Kuang, Jie; Wang, Yonggang; Cao, Qiang; Liu, Chong

    2018-05-01

    Time-to-digital convertors (TDCs) based on field programmable gate array (FPGA) are becoming more and more popular. Multi-measurement is an effective method to improve TDC precision beyond the cell delay limitation. However, the implementation of TDC with multi-measurement on FPGAs manufactured with 28 nm and more advanced process is facing new challenges. Benefiting from the ones-counter encoding scheme, which was developed in our previous work, we implement a ring oscillator multi-measurement TDC on a Xilinx Kintex-7 FPGA. Using the two TDC channels to measure time-intervals in the range (0 ns-30 ns), the average RMS precision can be improved to 5.76 ps, meanwhile the logic resource usage remains the same with the one-measurement TDC, and the TDC dead time is only 22 ns. The investigation demonstrates that the multi-measurement methods are still available for current main-stream FPGAs. Furthermore, the new implementation in this paper could make the trade-off among the time precision, resource usage and TDC dead time better than ever before.

  2. Thyroid dose measurement in patients undergoing to digital orthopantomography using optical stimulation dosimeters

    International Nuclear Information System (INIS)

    Gutierrez M, J. G.; Lopez V, A.; Rivera M, T.; Avalos P, L. Y.

    2016-10-01

    In this paper we present the study of the thyroid equivalent dose in 300 patients undergoing to digital orthopantomography for dental treatment purposes using optical stimulation dosimeters (OSL) as in-vivo dosimeters, in order to verify if this is within acceptable parameters to prevent stochastic risks and to evaluate the possible risks caused by the technique used for this type of study (66 kv, 5 m A, 14.1 s). Three OSL dosimeters were used per patient, which were placed by the physician on the skin above the thyroid gland (using anatomical references and palpation); the information of the patients was divided by neck size and sex, finding a slight increase in the equivalent dose for female and small size patient, this combination being the group that was submitted to a higher dose. The results obtained were compared with similar studies performed on anthropomorphic mannequins with TLD dosimeters obtaining lower results. The equivalent dose found even though is below the threshold stochastic damage must be motorized for radiological protection and registration purposes. (Author)

  3. MIMOSA-26 calibration and noise measurement based on the digital sensor output

    Energy Technology Data Exchange (ETDEWEB)

    Milanovic, Borislav [Goethe Uni Frankfurt (Germany); Collaboration: CBM-MVD-Collaboration

    2014-07-01

    CMOS Monolithic Active Pixel Sensors (MAPS) are used for high-precision tracking in particle detectors. They are applied for the STAR detector and also considered for the future CBM and ALICE experiments. MAPS combine high detection efficiency (> 99 %), with ultra-low material budget (thinned to 50 μm) and low power consumption (ca. 250 mW/cm{sup 2}). Their main feature is an integrated digital readout circuit situated directly on-chip. MIMOSA-26, developed at the IPHC Strasbourg, represents the basis of a modern MAPS. The sensor allows programming and slow control via JTAG. Sensitivity to impinging particles can be easily modified by changing the internal JTAG registers. However, the sensors require a careful tuning of run-time parameters, e.g. thresholds for the on-chip discriminators to guarantee a high detection efficiency and a low fake hit occupancy, i,e, electronic noise. This contribution presents a systematic study of the sensor/pixel response to noise allowing for a sensor characterization, calibration and selection prior to integration.

  4. Stress distribution retrieval in granular materials: A multi-scale model and digital image correlation measurements

    Science.gov (United States)

    Bruno, Luigi; Decuzzi, Paolo; Gentile, Francesco

    2016-01-01

    The promise of nanotechnology lies in the possibility of engineering matter on the nanoscale and creating technological interfaces that, because of their small scales, may directly interact with biological objects, creating new strategies for the treatment of pathologies that are otherwise beyond the reach of conventional medicine. Nanotechnology is inherently a multiscale, multiphenomena challenge. Fundamental understanding and highly accurate predictive methods are critical to successful manufacturing of nanostructured materials, bio/mechanical devices and systems. In biomedical engineering, and in the mechanical analysis of biological tissues, classical continuum approaches are routinely utilized, even if these disregard the discrete nature of tissues, that are an interpenetrating network of a matrix (the extra cellular matrix, ECM) and a generally large but finite number of cells with a size falling in the micrometer range. Here, we introduce a nano-mechanical theory that accounts for the-non continuum nature of bio systems and other discrete systems. This discrete field theory, doublet mechanics (DM), is a technique to model the mechanical behavior of materials over multiple scales, ranging from some millimeters down to few nanometers. In the paper, we use this theory to predict the response of a granular material to an external applied load. Such a representation is extremely attractive in modeling biological tissues which may be considered as a spatial set of a large number of particulate (cells) dispersed in an extracellular matrix. Possibly more important of this, using digital image correlation (DIC) optical methods, we provide an experimental verification of the model.

  5. Low level radioactivity measurements with phoswich detectors using coincident techniques and digital pulse processing analysis.

    Science.gov (United States)

    de la Fuente, R; de Celis, B; del Canto, V; Lumbreras, J M; de Celis Alonso, B; Martín-Martín, A; Gutierrez-Villanueva, J L

    2008-10-01

    A new system has been developed for the detection of low radioactivity levels of fission products and actinides using coincidence techniques. The device combines a phoswich detector for alpha/beta/gamma-ray recognition with a fast digital card for electronic pulse analysis. The phoswich can be used in a coincident mode by identifying the composed signal produced by the simultaneous detection of alpha/beta particles and X-rays/gamma particles. The technique of coincidences with phoswich detectors was proposed recently to verify the Nuclear Test Ban Treaty (NTBT) which established the necessity of monitoring low levels of gaseous fission products produced by underground nuclear explosions. With the device proposed here it is possible to identify the coincidence events and determine the energy and type of coincident particles. The sensitivity of the system has been improved by employing liquid scintillators and a high resolution low energy germanium detector. In this case it is possible to identify simultaneously by alpha/gamma coincidence transuranic nuclides present in environmental samples without necessity of performing radiochemical separation. The minimum detectable activity was estimated to be 0.01 Bq kg(-1) for 0.1 kg of soil and 1000 min counting.

  6. Residual stress measurement of PMMA by combining drilling-hole with digital speckle correlation method

    Science.gov (United States)

    Yao, X. F.; Xiong, T. C.; Xu, H. M.; Wan, J. P.; Long, G. R.

    2008-11-01

    The residual stresses of the PMMA (polymethyl methacrylate) specimens after being drilled, reamed and polished respectively are investigated using the digital speckle correlation experimental method,. According to the displacement fields around the correlated calculated region, the polynomial curve fitting method is used to obtain the continuous displacement fields, and the strain fields can be obtained from the derivative of the displacement fields. Considering the constitutive equation of the material, the expression of the residual stress can be presented. During the data processing, according to the fitting effect of the data, the calculation region of the correlated speckles and the degree of the polynomial fitting curve is decided. These results show that the maximum stress is at the hole-wall of the drilling hole specimen and with the increasing of the diameter of the drilled hole, the residual stress resulting from the hole drilling increases, whereas the process of reaming and polishing hole can reduce the residual stress. The relative large discrete degree of the residual stress is due to the chip removal ability of the drill bit, the cutting feed of the drill and other various reasons.

  7. Low level radioactivity measurements with phoswich detectors using coincident techniques and digital pulse processing analysis

    International Nuclear Information System (INIS)

    Fuente, R. de la; Celis, B. de; Canto, V. del; Lumbreras, J.M.; Celis, Alonso B. de; Martin-Martin, A.; Gutierrez-Villanueva, J.L.

    2008-01-01

    A new system has been developed for the detection of low radioactivity levels of fission products and actinides using coincidence techniques. The device combines a phoswich detector for α/β/γ-ray recognition with a fast digital card for electronic pulse analysis. The phoswich can be used in a coincident mode by identifying the composed signal produced by the simultaneous detection of α/β particles and X-rays/γ particles. The technique of coincidences with phoswich detectors was proposed recently to verify the Nuclear Test Ban Treaty (NTBT) which established the necessity of monitoring low levels of gaseous fission products produced by underground nuclear explosions. With the device proposed here it is possible to identify the coincidence events and determine the energy and type of coincident particles. The sensitivity of the system has been improved by employing liquid scintillators and a high resolution low energy germanium detector. In this case it is possible to identify simultaneously by α/γ coincidence transuranic nuclides present in environmental samples without necessity of performing radiochemical separation. The minimum detectable activity was estimated to be 0.01 Bq kg -1 for 0.1 kg of soil and 1000 min counting

  8. Bilateral Endoscopic Medial Maxillectomy for Bilateral Inverted Papilloma

    Directory of Open Access Journals (Sweden)

    Satoru Kodama

    2012-01-01

    Full Text Available Inverted papilloma (IP is a benign tumor of the nasal cavity and paranasal sinuses that is unilateral in most cases. Bilateral IP, involving both sides of the nasal cavity and sinuses, is extremely rare. This paper describes a large IP that filled in both sides of the nasal cavity and sinuses, mimicking association with malignancy. The tumor was successfully treated by bilateral endoscopic medial maxillectomy (EMM. The patient is without evidence of the disease 24 months after surgery. If preoperative diagnosis does not confirm the association with malignancy in IP, endoscopic sinus surgery (ESS should be selected, and ESS, including EMM, is a good first choice of the treatment for IP.

  9. Focus measure method based on the modulus of the gradient of the color planes for digital microscopy

    Science.gov (United States)

    Hurtado-Pérez, Román; Toxqui-Quitl, Carina; Padilla-Vivanco, Alfonso; Aguilar-Valdez, J. Félix; Ortega-Mendoza, Gabriel

    2018-02-01

    The modulus of the gradient of the color planes (MGC) is implemented to transform multichannel information to a grayscale image. This digital technique is used in two applications: (a) focus measurements during autofocusing (AF) process and (b) extending the depth of field (EDoF) by means of multifocus image fusion. In the first case, the MGC procedure is based on an edge detection technique and is implemented in over 15 focus metrics that are typically handled in digital microscopy. The MGC approach is tested on color images of histological sections for the selection of in-focus images. An appealing attribute of all the AF metrics working in the MGC space is their monotonic behavior even up to a magnification of 100×. An advantage of the MGC method is its computational simplicity and inherent parallelism. In the second application, a multifocus image fusion algorithm based on the MGC approach has been implemented on graphics processing units (GPUs). The resulting fused images are evaluated using a nonreference image quality metric. The proposed fusion method reveals a high-quality image independently of faulty illumination during the image acquisition. Finally, the three-dimensional visualization of the in-focus image is shown.

  10. Study on highly reliable digital communication technology of reactor nuclear measuring equipment

    International Nuclear Information System (INIS)

    Gu Pengfei; Huang Xiaojin

    2007-01-01

    To meet the need of highly reliable of reactor nuclear measuring equipment, in allusion to the idiographic request of nuclear measuring equipment, the actual technical development and the application in industrial field, we design a kind of redundancy communication net based on PROFIBUS, and a kind of communication interface module based on redundancy PROFIBUS communication, which link the nuclear measuring equipment and PROFIBUS communication net, and also lay a foundation for advanced research. (authors)

  11. Thermal diffusivity measurement in thin metallic filaments using the mirage method with multiple probe beams and a digital camera

    Science.gov (United States)

    Vargas, E.; Cifuentes, A.; Alvarado, S.; Cabrera, H.; Delgado, O.; Calderón, A.; Marín, E.

    2018-02-01

    Photothermal beam deflection is a well-established technique for measuring thermal diffusivity. In this technique, a pump laser beam generates temperature variations on the surface of the sample to be studied. These variations transfer heat to the surrounding medium, which may be air or any other fluid. The medium in turn experiences a change in the refractive index, which will be proportional to the temperature field on the sample surface when the distance to this surface is small. A probe laser beam will suffer a deflection due to the refractive index periodical changes, which is usually monitored by means of a quadrant photodetector or a similar device aided by lock-in amplification. A linear relationship that arises in this technique is that given by the phase lag of the thermal wave as a function of the distance to a punctual heat source when unidimensional heat diffusion can be guaranteed. This relationship is useful in the calculation of the sample's thermal diffusivity, which can be obtained straightforwardly by the so-called slope method, if the pump beam modulation frequency is well-known. The measurement procedure requires the experimenter to displace the probe beam at a given distance from the heat source, measure the phase lag at that offset, and repeat this for as many points as desired. This process can be quite lengthy in dependence of the number points. In this paper, we propose a detection scheme, which overcomes this limitation and simplifies the experimental setup using a digital camera that substitutes all detection hardware utilizing motion detection techniques and software digital signal lock-in post-processing. In this work, the method is demonstrated using thin metallic filaments as samples.

  12. Nonlinear digital signal processing in mental health: characterization of major depression using instantaneous entropy measures of heartbeat dynamics.

    Science.gov (United States)

    Valenza, Gaetano; Garcia, Ronald G; Citi, Luca; Scilingo, Enzo P; Tomaz, Carlos A; Barbieri, Riccardo

    2015-01-01

    Nonlinear digital signal processing methods that address system complexity have provided useful computational tools for helping in the diagnosis and treatment of a wide range of pathologies. More specifically, nonlinear measures have been successful in characterizing patients with mental disorders such as Major Depression (MD). In this study, we propose the use of instantaneous measures of entropy, namely the inhomogeneous point-process approximate entropy (ipApEn) and the inhomogeneous point-process sample entropy (ipSampEn), to describe a novel characterization of MD patients undergoing affective elicitation. Because these measures are built within a nonlinear point-process model, they allow for the assessment of complexity in cardiovascular dynamics at each moment in time. Heartbeat dynamics were characterized from 48 healthy controls and 48 patients with MD while emotionally elicited through either neutral or arousing audiovisual stimuli. Experimental results coming from the arousing tasks show that ipApEn measures are able to instantaneously track heartbeat complexity as well as discern between healthy subjects and MD patients. Conversely, standard heart rate variability (HRV) analysis performed in both time and frequency domains did not show any statistical significance. We conclude that measures of entropy based on nonlinear point-process models might contribute to devising useful computational tools for care in mental health.

  13. Measurement and evaluation of digital cervicography programs in two cervical cancer screening camps in East Africa

    Science.gov (United States)

    Peterson, Curtis W.; Mink, Jonah; Levitz, David

    2017-03-01

    Cervical cancer disproportionately affects women living in low- and middle-income countries. To address this global crisis, many governments and NGOs have implemented community-based screening and treatment programs at outreach camps. Here, high volumes of patients are able to access care: screening and diagnosis followed by immediate treatment of precancerous lesions onsite. However, monitoring and evaluation (M&E) of these efforts presents challenges, since each event typically relies on a different health workforce, and refers patients to different facilities for follow up and advanced care. To address these challenges, a digital imaging intervention was deployed at several screening camps in East Africa. Trained nurses screened women using a connected low-cost mobile colposcope built around a smartphone. A decision support job aid was integrated into the app controlling the device, guiding nurses and recording their diagnosis and treatment decisions. Aggregating the data from the job aid allowed M&E of the screening camp in real-time. In this paper, the M&E data from 2 different screening camps in East Africa are compared. Additionally, screening camps are compared to stationary clinics. Differences in the patient screening times, treatment rates, and individual nurse statistics were all documented through the job aid allowing for much improved epidemiological information following outreach events thus enabling targeted program improvements and provider training. Reporting data from screening camps were also shared online via public web pages, facilitating broader dissemination of health needs in specific East African communities, and sparking conversations with regional stakeholders about local disease burden.

  14. Mental workload measurement for emergency operating procedures in digital nuclear power plants.

    Science.gov (United States)

    Gao, Qin; Wang, Yang; Song, Fei; Li, Zhizhong; Dong, Xiaolu

    2013-01-01

    Mental workload is a major consideration for the design of emergency operation procedures (EOPs) in nuclear power plants. Continuous and objective measures are desired. This paper compares seven mental workload measurement methods (pupil size, blink rate, blink duration, heart rate variability, parasympathetic/sympathetic ratio, total power and (Goals, Operations, Methods, and Section Rules)-(Keystroke Level Model) GOMS-KLM-based workload index) with regard to sensitivity, validity and intrusiveness. Eighteen participants performed two computerised EOPs of different complexity levels, and mental workload measures were collected during the experiment. The results show that the blink rate is sensitive to both the difference in the overall task complexity and changes in peak complexity within EOPs, that the error rate is sensitive to the level of arousal and correlate to the step error rate and that blink duration increases over the task period in both low and high complexity EOPs. Cardiac measures were able to distinguish tasks with different overall complexity. The intrusiveness of the physiological instruments is acceptable. Finally, the six physiological measures were integrated using group method of data handling to predict perceived overall mental workload. The study compared seven measures for evaluating the mental workload with emergency operation procedure in nuclear power plants. An experiment with simulated procedures was carried out, and the results show that eye response measures are useful for assessing temporal changes of workload whereas cardiac measures are useful for evaluating the overall workload.

  15. Tinnitus after Simultaneous and Sequential Bilateral Cochlear Implantation.

    Science.gov (United States)

    Ramakers, Geerte G J; Kraaijenga, Véronique J C; Smulders, Yvette E; van Zon, Alice; Stegeman, Inge; Stokroos, Robert J; Free, Rolien H; Frijns, Johan H M; Huinck, Wendy J; Van Zanten, Gijsbert A; Grolman, Wilko

    2017-01-01

    There is an ongoing global discussion on whether or not bilateral cochlear implantation should be standard care for bilateral deafness. Contrary to unilateral cochlear implantation, however, little is known about the effect of bilateral cochlear implantation on tinnitus. To investigate tinnitus outcomes 1 year after bilateral cochlear implantation. Secondarily, to compare tinnitus outcomes between simultaneous and sequential bilateral cochlear implantation and to investigate long-term follow-up (3 years). This study is a secondary analysis as part of a multicenter randomized controlled trial. Thirty-eight postlingually deafened adults were included in the original trial, in which the presence of tinnitus was not an inclusion criterion. All participants received cochlear implants (CIs) because of profound hearing loss. Nineteen participants received bilateral CIs simultaneously and 19 participants received bilateral CIs sequentially with an inter-implant interval of 2 years. The prevalence and severity of tinnitus before and after simultaneous and sequential bilateral cochlear implantation were measured preoperatively and each year after implantation with the Tinnitus Handicap Inventory (THI) and Tinnitus Questionnaire (TQ). The prevalence of preoperative tinnitus was 42% (16/38). One year after bilateral implantation, there was a median difference of -8 (inter-quartile range (IQR): -28 to 4) in THI score and -9 (IQR: -17 to -9) in TQ score in the participants with preoperative tinnitus. Induction of tinnitus occurred in five participants, all in the simultaneous group, in the year after bilateral implantation. Although the preoperative and also the postoperative median THI and TQ scores were higher in the simultaneous group, the median difference scores were equal in both groups. In the simultaneous group, tinnitus scores fluctuated in the 3 years after implantation. In the sequential group, four patients had an additional benefit of the second CI: a total

  16. Tinnitus after Simultaneous and Sequential Bilateral Cochlear Implantation

    Directory of Open Access Journals (Sweden)

    Geerte G. J. Ramakers

    2017-11-01

    Full Text Available ImportanceThere is an ongoing global discussion on whether or not bilateral cochlear implantation should be standard care for bilateral deafness. Contrary to unilateral cochlear implantation, however, little is known about the effect of bilateral cochlear implantation on tinnitus.ObjectiveTo investigate tinnitus outcomes 1 year after bilateral cochlear implantation. Secondarily, to compare tinnitus outcomes between simultaneous and sequential bilateral cochlear implantation and to investigate long-term follow-up (3 years.Study designThis study is a secondary analysis as part of a multicenter randomized controlled trial.MethodsThirty-eight postlingually deafened adults were included in the original trial, in which the presence of tinnitus was not an inclusion criterion. All participants received cochlear implants (CIs because of profound hearing loss. Nineteen participants received bilateral CIs simultaneously and 19 participants received bilateral CIs sequentially with an inter-implant interval of 2 years. The prevalence and severity of tinnitus before and after simultaneous and sequential bilateral cochlear implantation were measured preoperatively and each year after implantation with the Tinnitus Handicap Inventory (THI and Tinnitus Questionnaire (TQ.ResultsThe prevalence of preoperative tinnitus was 42% (16/38. One year after bilateral implantation, there was a median difference of −8 (inter-quartile range (IQR: −28 to 4 in THI score and −9 (IQR: −17 to −9 in TQ score in the participants with preoperative tinnitus. Induction of tinnitus occurred in five participants, all in the simultaneous group, in the year after bilateral implantation. Although the preoperative and also the postoperative median THI and TQ scores were higher in the simultaneous group, the median difference scores were equal in both groups. In the simultaneous group, tinnitus scores fluctuated in the 3 years after implantation. In the sequential group

  17. Binaural Speech Understanding With Bilateral Cochlear Implants in Reverberation.

    Science.gov (United States)

    Kokkinakis, Kostas

    2018-03-08

    The purpose of this study was to investigate whether bilateral cochlear implant (CI) listeners who are fitted with clinical processors are able to benefit from binaural advantages under reverberant conditions. Another aim of this contribution was to determine whether the magnitude of each binaural advantage observed inside a highly reverberant environment differs significantly from the magnitude measured in a near-anechoic environment. Ten adults with postlingual deafness who are bilateral CI users fitted with either Nucleus 5 or Nucleus 6 clinical sound processors (Cochlear Corporation) participated in this study. Speech reception thresholds were measured in sound field and 2 different reverberation conditions (0.06 and 0.6 s) as a function of the listening condition (left, right, both) and the noise spatial location (left, front, right). The presence of the binaural effects of head-shadow, squelch, summation, and spatial release from masking in the 2 different reverberation conditions tested was determined using nonparametric statistical analysis. In the bilateral population tested, when the ambient reverberation time was equal to 0.6 s, results indicated strong positive effects of head-shadow and a weaker spatial release from masking advantage, whereas binaural squelch and summation contributed no statistically significant benefit to bilateral performance under this acoustic condition. These findings are consistent with those of previous studies, which have demonstrated that head-shadow yields the most pronounced advantage in noise. The finding that spatial release from masking produced little to almost no benefit in bilateral listeners is consistent with the hypothesis that additive reverberation degrades spatial cues and negatively affects binaural performance. The magnitude of 4 different binaural advantages was measured on the same group of bilateral CI subjects fitted with clinical processors in 2 different reverberation conditions. The results of this work

  18. Bilateral pallidotomy for generalized dystonia Palidotomia bilateral para distonias generalizadas

    Directory of Open Access Journals (Sweden)

    Hélio A. G. Teive

    2001-06-01

    Full Text Available OBJECTIVE: To evaluate the efficacy and safety of bilateral pallidotomies in five patients with generalized dystonia. BACKGROUND: Generalized dystonias are frequently a therapeutic challenge, with poor responses to pharmacological treatment. GPi (globus pallidus internus pallidotomies for Parkinson's disease ameliorate all kinds of dyskinesias/dystonia, and recent studies reported a marked improvement of refractory dystonias with this procedure. METHODS: Five patients with generalized dystonias refractory to medical treatment were selected; one posttraumatic and four idiopathic. The decision to perform bilateral procedures was based on the predominant axial involvement in these patients. Dystonia severity was assessed with the Burke-Fahn-Marsden Dystonia Scale (BFM. Simultaneous procedures were performed in all but one patient, who had a staged procedure. They were reevaluated with the same scale (BFM by an unblinded rater at 1, 2, 3, 30, 60, 90, 120 and 180 days post-operatively. RESULTS: The four patients with idiopathic dystonia showed a progressive improvement up to three months; the patient with posttraumatic dystonia relapsed at three months. One patient had a marked improvement, being able to discontinue all the medications. A mean decrease in the BFM scores of 52,58% was noted. One patient had a trans-operative motor seizure followed by a transient hemiparesis secondary to rack hemorrhage; other was lethargic up to three days after the procedure. CONCLUSIONS: Our results show that bilateral GPi pallidotomies may be a safe and effective approach to medically refractory generalized dystonias; it can also be speculated that the posttraumatic subgroup may not benefit with this procedure.As distonias generalizadas são freqüentemente um desafio terapêutico, com pobres respostas aos tratamentos farmacológicos. As cirurgias estereotáxicas, como a palidotomia, têm sido utilizadas com êxito no tratamento da doença de Parkinson e estudos

  19. A novel method to measure skin mechanical properties with three-dimensional digital image correlation.

    Science.gov (United States)

    Xu, Z; Dela Cruz, J; Fthenakis, C; Saliou, C

    2018-06-06

    Measuring skin mechanical properties has been of great interest in the skincare industry. It is a high accuracy and non-invasive optical technique which quantitatively tracks skin movement and deformation under mechanical perturbations. A study was conducted with female subjects (25-65 years old). A refined speckle pattern applied onto the skin surface was used for DIC measurements. A unidirectional force pulled the skin at a constant velocity, while the deformation process was quantified by the DIC. Prior to the DIC measurement, Cutometer ® readings were taken on the same area. The DIC protocol's reproducibility across multiple pattern applications, the measurement's repeatability, and the sensitivity in differentiating skin mechanical properties were investigated. Subjects were clustered with statistical significance according to their skin mechanical properties described by six DIC metrics (μ [major strain], σ [major strain], μ [minor strain], σ [minor strain], μ [displacement], and σ [displacement]). Most measurement random errors are below 6%. This is several folds smaller in magnitude than the difference in the mean response between the clusters. Several Cutometer ® parameters also showed good agreement with μ (displacement). DIC was able to differentiate skins of different mechanical qualities. We also proposed the physical significance of the DIC metrics. Some of the DIC metrics potentially offer new insights into skin mechanical properties that complement those revealed by conventional instruments. Accurate measurements, large measurement areas along with ease of direct visualization are substantial advantages of DIC. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  20. Immediate Sequential Bilateral Cataract Surgery

    DEFF Research Database (Denmark)

    Kessel, Line; Andresen, Jens; Erngaard, Ditte

    2015-01-01

    The aim of the present systematic review was to examine the benefits and harms associated with immediate sequential bilateral cataract surgery (ISBCS) with specific emphasis on the rate of complications, postoperative anisometropia, and subjective visual function in order to formulate evidence......-based national Danish guidelines for cataract surgery. A systematic literature review in PubMed, Embase, and Cochrane central databases identified three randomized controlled trials that compared outcome in patients randomized to ISBCS or bilateral cataract surgery on two different dates. Meta-analyses were...... performed using the Cochrane Review Manager software. The quality of the evidence was assessed using the GRADE method (Grading of Recommendation, Assessment, Development, and Evaluation). We did not find any difference in the risk of complications or visual outcome in patients randomized to ISBCS or surgery...

  1. Accurate kinematic measurement at interfaces between dissimilar materials using conforming finite-element-based digital image correlation

    KAUST Repository

    Tao, Ran

    2016-02-11

    Digital image correlation (DIC) is now an extensively applied full-field measurement technique with subpixel accuracy. A systematic drawback of this technique, however, is the smoothening of the kinematic field (e.g., displacement and strains) across interfaces between dissimilar materials, where the deformation gradient is known to be large. This can become an issue when a high level of accuracy is needed, for example, in the interfacial region of composites or joints. In this work, we described the application of global conforming finite-element-based DIC technique to obtain precise kinematic fields at interfaces between dissimilar materials. Speckle images from both numerical and actual experiments processed by the described global DIC technique better captured sharp strain gradient at the interface than local subset-based DIC. © 2016 Elsevier Ltd. All rights reserved.

  2. BILATERAL DUPLICATION OF RENAL ARTERIES

    OpenAIRE

    Prajkta A Thete; Mehera Bhoir; M.V.Ambiye

    2014-01-01

    Routine dissection of a male cadaver revealed the presence of bilateral double renal arteries. On the right side the accessory renal artery originated from the abdominal aorta just above the main renal artery. On the left side the accessory renal artery originated from the abdominal aorta about 1 cm above the main renal artery. Knowledge of the variations of renal vascular anatomy has importance in exploration and treatment of renal trauma, renal transplantation, renal artery embolization, su...

  3. China's Bilateral Currency Swap Lines

    OpenAIRE

    Zhitao, Lin; Wenjie, Zhan; Cheung, Yin-Wong

    2016-01-01

    We study the determinants of China’s bilateral local currency swap lines that were established since the recent global finance crisis. It is found that economic factors, political considerations, and institutional characteristics including trade intensity, economic size, strategic partnership, free trade agreement, corruption, and stability affect the decision of signing a swap line agreement. Once a swap line agreement decision is made, the size of the swap line is then mainly affected by tr...

  4. Estimation of elastic modulus of reinforcement corrosion products using inverse analysis of digital image correlation measurements for input in corrosion-induced cracking model

    DEFF Research Database (Denmark)

    Pease, Bradley Justin; Michel, Alexander; Thybo, Anna Emilie A.

    2012-01-01

    A combined experimental and numerical approach for estimating the elastic modulus of reinforcement corrosion products is presented. Deformations between steel and mortar were measured using digital image correlation during accelerated corrosion testing at 100 μA/cm2 (~1.16 mm/year). Measured defo...

  5. Digital 2D-photogrammetry and direct anthropometry--a comparing study on test accomplishment and measurement data.

    Science.gov (United States)

    Franke-Gromberg, Christine; Schüler, Grit; Hermanussen, Michael; Scheffler, Christiane

    2010-01-01

    The aim of this methodological anthropometric study was to compare direct anthropometry and digital two-dimensional photogrammetry in 18 male and 27 female subjects, aged 24 to 65 years, from Potsdam, Germany. In view of the rising interest in reliable biometric kephalofacial data, we focussed on head and face measurements. Out of 34 classic facial anatomical landmarks, 27 landmarks were investigated both by direct anthropometry and 2D-photogrammetry; 7 landmarks could not be localized by 2D-photogrammetry. Twenty-six kephalofacial distances were analysed both by direct anthropometry and digital 2D-photogrammetry. Kephalofacial distances are on average 7.6% shorter when obtained by direct anthropometry. The difference between the two techniques is particularly evident in total head height (vertex-gnathion) due to the fact that vertex is usually covered by hair and escapes from photogrammetry. Also the distances photographic sellion-gnathion (1.3 cm, i. e. 11.6%) and nasal-gnathion (1.2 cm, i. e. 9.4%) differ by more than one centimetre. Differences below 0.5 cm between the two techniques were found when measuring mucosa-lip-height (2.2%), gonia (3.0%), glabella-stomion (3.9%), and nose height (glabella-subnasal) (4.0%). Only the estimates of forehead width were significantly narrower when obtained by 2D-photogrammetry (-1.4 cm, -13.1%). The methodological differences increased with increasing magnitude of the kephalometric distance. Apart from these limitations, both techniques are similarly valid and may replace each other.

  6. Development of the Digital Arthritis Index, a Novel Metric to Measure Disease Parameters in a Rat Model of Rheumatoid Arthritis

    Directory of Open Access Journals (Sweden)

    Maria A. Lim

    2017-11-01

    Full Text Available Despite a broad spectrum of anti-arthritic drugs currently on the market, there is a constant demand to develop improved therapeutic agents. Efficient compound screening and rapid evaluation of treatment efficacy in animal models of rheumatoid arthritis (RA can accelerate the development of clinical candidates. Compound screening by evaluation of disease phenotypes in animal models facilitates preclinical research by enhancing understanding of human pathophysiology; however, there is still a continuous need to improve methods for evaluating disease. Current clinical assessment methods are challenged by the subjective nature of scoring-based methods, time-consuming longitudinal experiments, and the requirement for better functional readouts with relevance to human disease. To address these needs, we developed a low-touch, digital platform for phenotyping preclinical rodent models of disease. As a proof-of-concept, we utilized the rat collagen-induced arthritis (CIA model of RA and developed the Digital Arthritis Index (DAI, an objective and automated behavioral metric that does not require human-animal interaction during the measurement and calculation of disease parameters. The DAI detected the development of arthritis similar to standard in vivo methods, including ankle joint measurements and arthritis scores, as well as demonstrated a positive correlation to ankle joint histopathology. The DAI also determined responses to multiple standard-of-care (SOC treatments and nine repurposed compounds predicted by the SMarTRTM Engine to have varying degrees of impact on RA. The disease profiles generated by the DAI complemented those generated by standard methods. The DAI is a highly reproducible and automated approach that can be used in-conjunction with standard methods for detecting RA disease progression and conducting phenotypic drug screens.

  7. Simultaneous and staged bilateral total hip arthroplasty

    DEFF Research Database (Denmark)

    Lindberg-Larsen, Martin; Joergensen, Christoffer Calov; Husted, Henrik

    2013-01-01

    Bilateral total hip arthroplasty (BTHA) and bilateral simultaneous total hip arthroplasty (BSTHA) are done increasingly. Previous studies evaluating outcomes after bilateral procedures have found different results. The aim of this study was to investigate length of hospital stay (LOS), 30 days...

  8. BILATERAL SINGLE SESSION URETEROSCOPY FOR URETERAL ...

    African Journals Online (AJOL)

    Objectives: To determine the feasibility, safety and success rate of bilateral single session rigid retrograde ureteroscopy (URS) for bilateral ureteral calculi. Patients and Methods: Thirty-five patients underwent bilateral single session ureteroscopic calculus removal. Results: Out of 70 renal units in 35 patients treated, ...

  9. Measurement of angles of abduction for diagnosis of shoulder instability in dogs using goniometry and digital image analysis.

    Science.gov (United States)

    Cook, James L; Renfro, Daniel C; Tomlinson, James L; Sorensen, Jill E

    2005-01-01

    To compare abduction angles of shoulders with medial instability and unaffected shoulders in the same dogs and in age- and breed-matched dogs. Case-control study. Dogs with medial instability of the shoulder (n=33) and 26 control dogs. Dogs were sedated and positioned in lateral recumbency with both scapulas parallel to the table. With the elbow and shoulder in extension, the non-recumbent limb was maximally abducted and the angle between the scapular spine and lateral aspect of the brachium measured with a goniometer; a digital image was taken from the cranial aspect. Both techniques were performed in triplicate by 2 examiners. Mean abduction angles for each shoulder were determined from goniometric measurements and image analysis. Data were analyzed for significant differences between affected and unaffected shoulders, measurement techniques, and examiners. Strength of correlation between measurement techniques was determined. Mean abduction angles for shoulders with instability (53.7+/-4.7 degrees goniometric, 51.2+/-4.9 degrees image) were significantly (P<.001) larger than for all unaffected shoulders (32.6+/-2.0 degrees goniometric, 30.9+/-2.3 degrees image). In dogs diagnosed with instability, affected shoulders had significantly (P<.001) larger abduction angles than the contralateral (unaffected) shoulders. No significant differences were identified between right and left shoulders for control dogs, measurement techniques, or examiners. A strong (r=0.90) significant (P<.001) positive correlation between measurement techniques was noted. Shoulder abduction angles measured under sedation provide objective data for diagnosis of shoulder instability in dogs. Shoulders with clinical and arthroscopic evidence of medial instability have significantly higher abduction angles than shoulders that are considered normal. Determination of shoulder abduction angles should be included in the diagnostic protocol for forelimb lameness assessment in dogs.

  10. Simultaneous bilateral cataract surgery: economic analysis; Helsinki Simultaneous Bilateral Cataract Surgery Study Report 2.

    Science.gov (United States)

    Leivo, Tiina; Sarikkola, Anna-Ulrika; Uusitalo, Risto J; Hellstedt, Timo; Ess, Sirje-Linda; Kivelä, Tero

    2011-06-01

    To present an economic-analysis comparison of simultaneous and sequential bilateral cataract surgery. Helsinki University Eye Hospital, Helsinki, Finland. Economic analysis. Effects were estimated from data in a study in which patients were randomized to have bilateral cataract surgery on the same day (study group) or sequentially (control group). The main clinical outcomes were corrected distance visual acuity, refraction, complications, Visual Function Index-7 (VF-7) scores, and patient-rated satisfaction with vision. Health-care costs of surgeries and preoperative and postoperative visits were estimated, including the cost of staff, equipment, material, floor space, overhead, and complications. The data were obtained from staff measurements, questionnaires, internal hospital records, and accountancy. Non-health-care costs of travel, home care, and time were estimated based on questionnaires from a random subset of patients. The main economic outcome measures were cost per VF-7 score unit change and cost per patient in simultaneous versus sequential surgery. The study comprised 520 patients (241 patients included non-health-care and time cost analyses). Surgical outcomes and patient satisfaction were similar in both groups. Simultaneous cataract surgery saved 449 Euros (€) per patient in health-care costs and €739 when travel and paid home-care costs were included. The savings added up to €849 per patient when the cost of lost working time was included. Compared with sequential bilateral cataract surgery, simultaneous bilateral cataract surgery provided comparable clinical outcomes with substantial savings in health-care and non-health-care-related costs. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  11. Digital photography and transparency-based methods for measuring wound surface area.

    Science.gov (United States)

    Bhedi, Amul; Saxena, Atul K; Gadani, Ravi; Patel, Ritesh

    2013-04-01

    To compare and determine a credible method of measurement of wound surface area by linear, transparency, and photographic methods for monitoring progress of wound healing accurately and ascertaining whether these methods are significantly different. From April 2005 to December 2006, 40 patients (30 men, 5 women, 5 children) admitted to the surgical ward of Shree Sayaji General Hospital, Baroda, had clean as well as infected wound following trauma, debridement, pressure sore, venous ulcer, and incision and drainage. Wound surface areas were measured by these three methods (linear, transparency, and photographic methods) simultaneously on alternate days. The linear method is statistically and significantly different from transparency and photographic methods (P value transparency and photographic methods (P value >0.05). Photographic and transparency methods provided measurements of wound surface area with equivalent result and there was no statistically significant difference between these two methods.

  12. Displacement measurement with nanoscale resolution using a coded micro-mark and digital image correlation

    Science.gov (United States)

    Huang, Wei; Ma, Chengfu; Chen, Yuhang

    2014-12-01

    A method for simple and reliable displacement measurement with nanoscale resolution is proposed. The measurement is realized by combining a common optical microscopy imaging of a specially coded nonperiodic microstructure, namely two-dimensional zero-reference mark (2-D ZRM), and subsequent correlation analysis of the obtained image sequence. The autocorrelation peak contrast of the ZRM code is maximized with well-developed artificial intelligence algorithms, which enables robust and accurate displacement determination. To improve the resolution, subpixel image correlation analysis is employed. Finally, we experimentally demonstrate the quasi-static and dynamic displacement characterization ability of a micro 2-D ZRM.

  13. Clinical trial comparing autogenous fascia lata sling and Gore-Tex suspension in bilateral congenital ptosis

    Directory of Open Access Journals (Sweden)

    Elsamkary MA

    2016-03-01

    Full Text Available Mahmoud Ahmed Elsamkary,1 Maged Maher Salib Roshdy1,2 1Ophthalmology Department, Faculty of Medicine, Ain Shams University, Cairo, Egypt; 2Pediatric Ophthalmology Department, Al Watany Eye Hospital, Cairo, Egypt Purpose: To study the effect of autogenous fascia lata sling (AFLS versus Gore-Tex suspension (GTS regarding the functional and aesthetic outcomes in patients with bilateral congenital ptosis. Patients and methods: A prospective comparative randomized single-center study enrolled 110 patients with bilateral congenital ptosis. One group (n=55 underwent AFLS and the second group (n=55 underwent GTS. Exclusion criteria were good levator function, absent Bell’s phenomenon, and abnormal ocular motility. Follow-up period was 2 years. Functional outcome was measured from digital photos by analysis of upper eyelid margin position relative to the superior limbus and classified as very good (<3 mm, good (3–5 mm, poor (>5 mm, and recurrent. Aesthetic outcome was assessed in terms of lid contour, symmetry of eyelid height, and lid crease presence. Complications were also reported. Results: Failure rate (recurrence and complications was less in AFLS (P=0.035. Symmetrical lid height and good contour were more frequently attained by AFLS (P=0.007 and 0.047, respectively. However, the frequency of very good, good, poor, recurrence, lagopthalmos, ectropion, infection, and formed lid crease individually showed no statistically significant difference (P=0.252, 0.482, 1, 0.489, 0.438, 1, 0.618, and 0.506, respectively. Conclusion: AFLS is a better choice in surgery for patients with bilateral congenital ptosis because it has fewer complications and a lesser recurrence rate than GTS. Keywords: ptosis surgery, surgical outcomes, ptosis recurrence, lagophthalmos

  14. WE-DE-207B-05: Measuring Spatial Resolution in Digital Breast Tomosynthesis: Update of AAPM Task Group 245

    Energy Technology Data Exchange (ETDEWEB)

    Scaduto, DA; Hu, Y-H; Zhao, W [Stony Brook Medicine, Stony Brook, NY (United States); Goodsitt, M; Chan, H-P [University Michigan, Ann Arbor, MI (United States); Olafsdottir, H [Image Owl, 105 Reykjavik (Iceland); Das, M [University Houston, Houston, TX (United States); Fredenberg, E [Philips Healthcare, Solna (Sweden); Geiser, W [UT MD Anderson Cancer Center, Houston, TX (United States); Goodenough, D [The George Washington University, Washington, DC (United States); Heid, P [ARCADES, Marseille (France); Liu, B [Massachusetts General Hospital, Boston, MA (United States); Mainprize, J [Sunnybrook Health Sciences Centre, North York, ON (Canada); Reiser, I [The University of Chicago, Chicago, IL (United States); Van Engen, R [LRCB, Nijmegen (Netherlands); Varchena, V [CIRS Inc., Norfolk, VA (United States); Vecchio, S [I.M.S., Pontecchio Marconi (Italy); Glick, S [Food and Drug Administration, Silver Spring, MD (United States)

    2016-06-15

    Purpose: Spatial resolution in digital breast tomosynthesis (DBT) is affected by inherent/binned detector resolution, oblique entry of x-rays, and focal spot size/motion; the limited angular range further limits spatial resolution in the depth-direction. While DBT is being widely adopted clinically, imaging performance metrics and quality control protocols have not been standardized. AAPM Task Group 245 on Tomosynthesis Quality Control has been formed to address this deficiency. Methods: Methods of measuring spatial resolution are evaluated using two prototype quality control phantoms for DBT. Spatial resolution in the detector plane is measured in projection and reconstruction domains using edge-spread function (ESF), point-spread function (PSF) and modulation transfer function (MTF). Spatial resolution in the depth-direction and effective slice thickness are measured in the reconstruction domain using slice sensitivity profile (SSP) and artifact spread function (ASF). An oversampled PSF in the depth-direction is measured using a 50 µm angulated tungsten wire, from which the MTF is computed. Object-dependent PSF is derived and compared with ASF. Sensitivity of these measurements to phantom positioning, imaging conditions and reconstruction algorithms is evaluated. Results are compared from systems of varying acquisition geometry (9–25 projections over 15–60°). Dependence of measurements on feature size is investigated. Results: Measurements of spatial resolution using PSF and LSF are shown to depend on feature size; depth-direction spatial resolution measurements are shown to similarly depend on feature size for ASF, though deconvolution with an object function removes feature size-dependence. A slanted wire may be used to measure oversampled PSFs, from which MTFs may be computed for both in-plane and depth-direction resolution. Conclusion: Spatial resolution measured using PSF is object-independent with sufficiently small object; MTF is object

  15. Procedure for the standardized measure of the detective quantum efficiency in digital mammography

    International Nuclear Information System (INIS)

    Rodriguez Martin, G.; Garcia Castano, P.; Bermudez Luna, R.; Fernandez Bedoya, V.; Espana Lopez, M. L.; Miquelez Alonso, S.

    2011-01-01

    The objective of this work is to develop a simple guide for determining the DQE, according to the CEI, in those having mammography flat panel detectors, and highlight the main difficulties that may be in the process of the standardized measurement.

  16. Computer Tomography and Hybrid Optical/Digital Methods for Aerodynamic Measurements.

    Science.gov (United States)

    1987-12-28

    Industrial Applications of Corn- on Axisymnnietric Flame ’Iempnlw res Measured by Holo- puted Tornographv arid NMI? Imiaging (Optical Society of graphic...Pontificia Universidad Catolica de Chile. Escuela de Ingenieria . Santiago, equal. The optical path length difference (OPD) be- Chile. tween the two rays

  17. Digital design and fabrication of simulation model for measuring orthodontic force.

    Science.gov (United States)

    Liu, Yun-Feng; Zhang, Peng-Yuan; Zhang, Qiao-Fang; Zhang, Jian-Xing; Chen, Jie

    2014-01-01

    Three dimensional (3D) forces are the key factors for determining movement of teeth during orthodontic treatment. Designing precise forces and torques on tooth before treatment can result accurate tooth movements, but it is too difficult to realize. In orthodontic biomechanical systems, the periodontal tissues, including bones, teeth, and periodontal ligaments (PDL), are affected by braces, and measuring the forces applied on the teeth by braces should be based on a simulated model composed of these three types of tissues. This study explores the design and fabrication of a simulated oral model for 3D orthodontic force measurements. Based on medical image processing, tissue reconstruction, 3D printing, and PDL simulation and testing, a model for measuring force was designed and fabricated, which can potentially be used for force prediction, design of treatment plans, and precise clinical operation. The experiment illustrated that bi-component silicones with 2:8 ratios had similar mechanical properties to PDL, and with a positioning guide, the teeth were assembled in the mandible sockets accurately, and so a customized oral model for 3D orthodontic force measurement was created.

  18. Bilateral cochlear implantation in a patient with bilateral temporal bone fractures.

    Science.gov (United States)

    Chung, Jae Ho; Shin, Myung Chul; Min, Hyun Jung; Park, Chul Won; Lee, Seung Hwan

    2011-01-01

    With the emphasis on bilateral hearing nowadays, bilateral cochlear implantation has been tried out for bilateral aural rehabilitation. Bilateral sensorineural hearing loss caused by head trauma can get help from cochlear implantation. We present the case of a 44-year-old man with bilateral otic capsule violating temporal bone fractures due to head trauma. The patient demonstrated much improved audiometric and psychoacoustic performance after bilateral cochlear implantation. We believe bilateral cochlear implantation in such patient can be a very effective tool for rehabilitation. Copyright © 2011 Elsevier Inc. All rights reserved.

  19. Local liquid velocity measurement in trickle bed reactors (TBRs) using the x-ray digital industrial radiography (DIR) technique

    Science.gov (United States)

    Anuar Mohd Salleh, Khairul; Lee, Hyoung Koo; Al-Dahhan, Muthanna H.

    2014-01-01

    This work describes the development of a new technique to measure local liquid velocity (VLL) for multiphase flows in trickle bed reactors (TBRs) (gas-liquid-solid system). In the studied TBR, the liquid phase is represented by water, gas by air and 3 mm expanded polystyrene beads as the solid packing. Three different superficial liquid velocities (VSL) and a constant superficial gas velocity (VSG) were used in the packed bed with an internal diameter of 4.25 cm. While the liquid is moving into the packed bed, tracking particles of 106-125 μm diameter (16.45% difference) are injected. The movement of the tracking particles is monitored and digitally recorded by a complementary metal-oxide-semiconductor detector. In this experiment, x-rays were used as the radiation source. Four replications were made with fresh packing. Comparable observations can be found from other published techniques (i.e. magnetic resonance imaging). Results from this study indicate that, at VSL = 0.13 cm s-1, the measured VLL can reach up to 51 times that of its VSL, while for VSL = 0.27 cm s-1, the measured VLL reached up to 35 times higher than the VSL and for VSL = 0.39 cm s-1, the VLL reached up to 39.8 times higher than its VSL. Through statistical analysis, the implementation of such a method is found to be reproducible throughout the experiments. The mean per cent difference in the measured VLL was 10% and 5% for lower implemented VSL of 0.13 and 0.27 cm s-1, respectively. At higher VSL (0.39 cm s-1), the particle tracer was greatly distributed and carried away by the high liquid flow rate. The variance or the range of the measured VLL does not vary for all replications in every VSL, which confirms the reproducibility of the experimental measurements, regardless of the VSL.

  20. Strain measurement of objects subjected to aerodynamic heating using digital image correlation: experimental design and preliminary results.

    Science.gov (United States)

    Pan, Bing; Jiang, Tianyun; Wu, Dafang

    2014-11-01

    In thermomechanical testing of hypersonic materials and structures, direct observation and quantitative strain measurement of the front surface of a test specimen directly exposed to severe aerodynamic heating has been considered as a very challenging task. In this work, a novel quartz infrared heating device with an observation window is designed to reproduce the transient thermal environment experienced by hypersonic vehicles. The specially designed experimental system allows the capture of test article's surface images at various temperatures using an optical system outfitted with a bandpass filter. The captured images are post-processed by digital image correlation to extract full-field thermal deformation. To verify the viability and accuracy of the established system, thermal strains of a chromiumnickel austenite stainless steel sample heated from room temperature up to 600 °C were determined. The preliminary results indicate that the air disturbance between the camera and the specimen due to heat haze induces apparent distortions in the recorded images and large errors in the measured strains, but the average values of the measured strains are accurate enough. Limitations and further improvements of the proposed technique are discussed.

  1. Design and application of a continuous, digital-output, environmental radon measuring instrument

    International Nuclear Information System (INIS)

    Spitz, H.; Wrenn, M.E.

    1977-01-01

    A radon measuring instrument has been developed which can continuously measure environmental concentrations of radon in the atmosphere without employing any air movers or pumps. The unit is entirely passive in design and relies upon the diffusion of radon for sample collection. Since radon is an inert noble gas it will follow the classical theory of motion and diffuse in a direction dependent upon the concentration gradient existing between the atmosphere and the sensitive portion of the detector. A porous foam filter allows radon, but not its daughters, to enter the detector where an electrostatic field is maintained to facilitate collection of the decay products of radon, i.e., initially the positive ions of RaA (Po-218). Alpha particles from RaA and RaC' (Po-214) within the sensitive volume are detected using a ZnS scintillator and photomultiplier tube with the usual complement of electronics

  2. Practical Testing and Performance Analysis of Phasor Measurement Unit Using Real Time Digital Simulator (RTDS)

    DEFF Research Database (Denmark)

    Liu, Leo; Rather, Zakir Hussain; Stearn, Nathen

    2012-01-01

    Wide Area Measurement Systems (WAMS) and Wide Area Monitoring, Protection and Control Systems (WAMPACS) have evolved rapidly over the last two decades [1]. This fast emerging technology enables real time synchronized monitoring of power systems. Presently, WAMS are mainly used for real time...... visualisation and post event analysis of power systems. It is expected however, that through integration with traditional Supervisory Control and Data Acquisition (SCADA) systems, closed loop control applications will be possible. Phasor Measurement Units (PMUs) are fundamental components of WAMS. Large WAMS...... proposed to realize highly precise phasoreasurements. Further a comparative study based on features of PMUs from different major manufacturers is presented. The selection of optimal parameters, such as phasor format and filter length is also discussed for various applications....

  3. A digital instrument for nondestructive measurements of coating thicknesses by beta backscattering

    Science.gov (United States)

    Farcasiu, D. M.; Apostolescu, T.; Bozdog, H.; Badescu, E.; Bohm, V.; Stanescu, S. P.; Jianu, A.; Bordeanu, C.; Cracium, M. V.

    1992-02-01

    The elements of nondestructive gauging of coatings applied on various metal bases are presented. The intensity of the backscattered beta radiations is related to the thickness of the coating. With a fixed measuring geometry and radioactive sources (147Pm, 204Tl, 90Sr+90Y) the intensity of the backscattered beta particles is dependent on the following parameters: coating thickness, atomic number of the coating material and of the base, the beta particle energy and the surface finish. It can be used for the measurement of a wide range of coating thicknesses provided that the difference between the coating and the support atomic numbers is at least 20%. Fields of application include electronics, electrotechnique and so on.

  4. A digital instrument for nondestructive measurements of coating thicknesses by beta backscattering

    International Nuclear Information System (INIS)

    Farcasiu, D.M.; Apostolescu, T.; Bozdog, H.; Badescu, E.; Bohm, V.; Stanescu, S.P.; Jianu, A.; Bordeanu, C.; Craciun, M.V.

    1992-01-01

    The elements of nondestructive gauging of coatings applied on various metal bases are presented. The intensity of the backscattered beta radiations is related to the thickness of the coating. With a fixed measuring geometry and radioactive sources ( 147 Pm, 204 Tl, 90 Sr+ 90 Y) the intensity of the backscattered beta particles is dependent on the following parameters: Coating thickness, atomic number of the coating material and of the base, the beta particle energy and the surface finish. It can be used for the measurement of a wide range of coating thicknesses provided that the difference between the coating and the support atomic numbers is at least 20%. Fields of application include electronics, electrotechnique and so on. (orig.)

  5. Doubling time measurement by method of digital integration of pulses from a CFU7 detector

    International Nuclear Information System (INIS)

    Gauthier, Guy

    1968-01-01

    The author reports an experimental study which aimed at measuring the doubling time with a CFU7 fission chamber by using an integration method on the Siloette pile with a new core and with a spent core, and at comparing results with those obtained with a specific instrument which receives information from an ionisation chamber. The interest of this method relies on the fact that the fission chamber is insensitive to gamma radiations

  6. Digital Measurement System for the HIE-Isolde Superconducting Accelerating Cavities

    CERN Document Server

    Elias, Michal

    Extensive R&D efforts are being invested at CERN into the fundamental science of the RF superconductivity, cavity design, niobium sputtering, coating and RF properties of superconducting cavities. Fast and precise characterization and measurements of RF parameters of the newly produced cavities is essential for advances with the cavity production. The currently deployed analogue measurement system based on an analogue phase discriminators and tracking RF generators is not optimal for efficient work at the SM18 superconducting cavity test stand. If exact properties of the cavity under test are not known a traditional feedback loop will not be able to find resonant frequency in a reasonable time or even at all. This is mainly due to a very high Q factor. The resonance peak is very narrow (fraction of a Hz at 100 MHz). If the resonant frequency is off by several bandwidths, small changes of the cavity field during the tuning will not be measureable. Also cavity field will react only very slowly to any change...

  7. Deployment of quasi-digital sensor for high temperature molten salt level measurement in pyroprocessing plants

    Science.gov (United States)

    Sanga, Ramesh; Agarwal, Sourabh; Sivaramakrishna, M.; Rao, G. Prabhakara

    2018-04-01

    Development of a liquid molten salt level sensor device that can detect the level of liquid molten salt in the process vessels of pyrochemical reprocessing of spent metallic fuels is detailed. It is proposed to apply a resistive-type pulsating sensor-based level measurement approach. There are no commercially available sensors due to limitations of high temperature, radiation, and physical dimensions. A compact, simple, rugged, low power, and high precise pulsating sensor-based level probe and simple instrumentation for the molten salt liquid level sensor to work in the extreme conditions has been indigenously developed, with high precision and accuracy. The working principle, design concept, and results have been discussed. This level probe is mainly composed of the variable resistor made up of ceramic rods. This resistor constitutes the part of resistance-capacitance-type Logic Gate Oscillator (LGO). A change in the molten salt level inside the tank causes a small change in the resistance which in turn changes the pulse frequency of the LGO. Thus the frequency, the output of the instrument that is displayed on the LCD of an embedded system, is a function of molten salt level. In the present design, the range of level measurement is about 10 mm. The sensitivity in position measurement up to 10 mm is ˜2.5 kHz/mm.

  8. Coincidence measurements in α/β/γ spectrometry with phoswich detectors using digital pulse shape discrimination analysis

    International Nuclear Information System (INIS)

    Celis, B. de; Fuente, R. de la; Williart, A.; Celis Alonso, B. de

    2007-01-01

    A novel system has been developed for the detection of low radioactivity levels using coincidence techniques. The device combines a phoswich detector for α/β/γ ray recognition with a fast digital card for electronic pulse analysis. The detector is able to discriminate different types of radiation in a mixed α/β/γ field and can be used in a coincidence mode by identifying the composite signal produced by the simultaneous detection of β particles in a plastic scintillator and γ rays in an NaI(Tl) scintillator. Use of a coincidence technique with phoswich detectors was proposed recently to verify the Nuclear Test Ban Treaty, which made it necessary to monitor the low levels of xenon radioisotopes produced by underground nuclear explosions. Previous studies have shown that combining CaF 2 (Eu) for β ray detection and NaI(Tl) for γ ray detection makes it difficult to identify the coincidence signals because of the similar fluorescence decay times of the two scintillators. With the device proposed here, it is possible to identify the coincidence events owing to the short fluorescence decay time of the plastic scintillator. The sensitivity of the detector may be improved by employing liquid scintillators, which allow low radioactivity levels from actinides to be measured when present in environmental samples. The device developed is simpler to use than conventional coincidence equipment because it uses a single detector and electronic circuit, and it offers fast and precise analysis of the coincidence signals by employing digital pulse shape analysis

  9. Bilateral Complete and Incomplete Fusion of Incisors and its Management.

    Science.gov (United States)

    Da Costa, Godwin Clovis; Chalakkal, Paul; De Souza, Neil; Gavhane, Sanket

    2017-01-01

    This case report highlights the management of a case of bilateral complete and incomplete fusion of maxillary incisors in a 10-year-old child. A mock-up was done on the diagnostic cast. Pretreatment esthetic evaluation was done using bis-acryl composite temporaries which were transferred intraorally from the diagnostic cast using a putty index. An incisal overlap veneer preparation was done, following which, an IPS e-max veneer was cemented. A digital mock-up was carried out using the Adobe Photoshop and Corel Draw softwares to aid in laboratorial fabrication of the veneer.

  10. Bilateral complete and incomplete fusion of incisors and its management

    Directory of Open Access Journals (Sweden)

    Godwin Clovis Da Costa

    2017-01-01

    Full Text Available This case report highlights the management of a case of bilateral complete and incomplete fusion of maxillary incisors in a 10-year-old child. A mock-up was done on the diagnostic cast. Pretreatment esthetic evaluation was done using bis-acryl composite temporaries which were transferred intraorally from the diagnostic cast using a putty index. An incisal overlap veneer preparation was done, following which, an IPS e-max veneer was cemented. A digital mock-up was carried out using the Adobe Photoshop and Corel Draw softwares to aid in laboratorial fabrication of the veneer.

  11. Hydraulic bilateral construction robot; Yuatsushiki bilateral kensetsu robot

    Energy Technology Data Exchange (ETDEWEB)

    Maehata, K.; Mori, N. [Kayaba Industry Co. Ltd., Tokyo (Japan)

    1999-05-15

    Concerning a hydraulic bilateral construction robot, its system constitution, structures and functions of important components, and the results of some tests are explained, and the researches conducted at Gifu University are described. The construction robot in this report is a servo controlled system of a version developed from the mini-shovel now available in the market. It is equipped, in addition to an electrohydraulic servo control system, with various sensors for detecting the robot attitude, vibration, and load state, and with a camera for visualizing the surrounding landscape. It is also provided with a bilateral joy stick which is a remote control actuator capable of working sensation feedback and with a rocking unit that creates robot movements of rolling, pitching, and heaving. The construction robot discussed here, with output increased and response faster thanks to the employment of a hydraulic driving system for the aim of building a robot system superior in performance to the conventional model designed primarily for heavy duty, proves after tests to be a highly sophisticated remotely controlled robot control system. (NEDO)

  12. Surge Flow in a Centrifugal Compressor Measured by Digital Particle Image Velocimetry

    Science.gov (United States)

    Wernet, Mark P.

    2000-01-01

    A planar optical velocity measurement technique known as Particle Image Velocimetry (PIV) is being used to study transient events in compressors. In PIV, a pulsed laser light sheet is used to record the positions of particles entrained in a fluid at two instances in time across a planar region of the flow. Determining the recorded particle displacement between exposures yields an instantaneous velocity vector map across the illuminated plane. Detailed flow mappings obtained using PIV in high-speed rotating turbomachinery components are used to improve the accuracy of computational fluid dynamics (CFD) simulations, which in turn, are used to guide advances in state-of-the-art aircraft engine hardware designs.

  13. In line digital holography measurement for liquid-liquid flow: application to the characterization of emulsions produced in pulsed column

    International Nuclear Information System (INIS)

    Lamadie, F.

    2013-01-01

    Several processes used in research and industry are based on liquid-liquid extraction, a method designed for selective separation of products in a mixture. In liquid-liquid extraction, two immiscible liquids are contacted: an aqueous phase and an organic phase, one of which generally contains an extractant molecule capable of transferring the desired elements to the other phase. The transfer occurs at the contact surface between the two phases. After transfer, both phases are separated by settling. In practice, these operations are performed in industrial apparatus. In order to optimize the operation of these devices, it's important to determine the fundamental characteristics of the emulsion. These include parameters related to the fluid flow velocity as well as parameters related to fluid mixing such as the interfacial area, hold-up, and size distribution of the droplets population. Numerous imaging techniques can be used to measure these parameters. One of them, digital holography, is well-known for allowing complete reconstruction of information about a 3D flow in a single shot. This PhD work deals with a direct application of digital in line holography to droplets rising in a continuous liquid phase. The droplet size imposes a regime of intermediate-field diffraction hardly explored to date. Acquired diffraction patterns show that the usual dark disk model is not valid and that good agreement is obtained with a mixed model coupling thin lens with opaque disk. Hologram focusing is nevertheless performed with a dedicated automated method. A literature review has been conducted to identify the sharpest auto-focus function for our application. In a second step, in order to measure high retention rates, an inverse problem approach is applied on all the outliers and missing droplets. This hologram restitution treatment has been applied to experimental results with a comparison to independent measurements. The main results obtained with calibrated droplets are

  14. The measurement of digital systolic blood pressure by strain gauge technique

    DEFF Research Database (Denmark)

    Nielsen, P E; Bell, G; Lassen, N A

    1972-01-01

    The systolic blood pressure on the finger, toe, and ankle has been measured by a strain gauge technique in 10 normal subjects aged 17-31 years and 14 normal subjects aged 43-57 years. The standard deviation in repeated measurements lies between 2 and 6 mm Hg. The finger pressure in the younger...... group was significantly higher than the corresponding arm pressure (+ 9.3 mm Hg, S.D. 6.8), but equalled this in the older group (- 0.5 mm Hg, S.D. 6.6). In the two groups the ankle pressures were + 19.3 mm Hg (S.D. 7.5) and + 23.6 mm Hg (S.D. 9.5) higher than the systolic arm pressures. The toe...... pressures were lower than the arm pressures, in the two groups - 4.8 mm Hg (S.D. 6.6) and - 9.8 mm Hg (S.D. 10.7) respectively. The ankle-toe gradient was in the younger group 24.3 mm Hg (S.D. 7.3) and in the older group 33.3 mm Hg (S.D. 12.1). Using mean minus 2.5 X S.D. as the lower limit of normality...

  15. Bilateral cleft lip nasal deformity

    Directory of Open Access Journals (Sweden)

    Singh Arun

    2009-01-01

    Full Text Available Bilateral cleft lip nose deformity is a multi-factorial and complex deformity which tends to aggravate with growth of the child, if not attended surgically. The goals of primary bilateral cleft lip nose surgery are, closure of the nasal floor and sill, lengthening of the columella, repositioning of the alar base, achieving nasal tip projection, repositioning of the lower lateral cartilages, and reorienting the nares from horizontal to oblique position. The multiplicity of procedures in the literature for correction of this deformity alludes to the fact that no single procedure is entirely effective. The timing for surgical intervention and its extent varies considerably. Early surgery on cartilage may adversely affect growth and development; at the same time, allowing the cartilage to grow in an abnormal position and contributing to aggravation of deformity. Some surgeons advocate correction of deformity at an early age. However, others like the cartilages to grow and mature before going in for surgery. With peer pressure also becoming an important consideration during the teens, the current trend is towards early intervention. There is no unanimity in the extent of nasal dissection to be done at the time of primary lip repair. While many perform limited nasal dissection for the fear of growth retardation, others opt for full cartilage correction at the time of primary surgery itself. The value of naso-alveolar moulding (NAM too is not universally accepted and has now more opponents than proponents. Also most centres in the developing world have neither the personnel nor the facilities for the same. The secondary cleft nasal deformity is variable and is affected by the extent of the original abnormality, any prior surgeries performed and alteration due to nasal growth. This article reviews the currently popular methods for correction of nasal deformity associated with bilateral cleft lip, it′s management both at the time of cleft lip repair

  16. Quantitative assessment of paretic limb dexterity and interlimb coordination during bilateral arm rehabilitation training.

    Science.gov (United States)

    Xu, Chang; Li, Siyi; Wang, Kui; Hou, Zengguang; Yu, Ningbo

    2017-07-01

    In neuro-rehabilitation after stroke, the conventional constrained induced movement therapy (CIMT) has been well-accepted. Existing bilateral trainings are mostly on mirrored symmetrical motion. However, complementary bilateral movements are dominantly involved in activities of daily living (ADLs), and functional bilateral therapies may bring better skill transfer from trainings to daily life. Neurophysiological evidence is also growing. In this work, we firstly introduce our bilateral arm training system realized with a haptic interface and a motion sensor, as well as the tasks that have been designed to train both the manipulation function of the paretic arm and coordination of bilateral upper limbs. Then, we propose quantitative measures for functional assessment of complementary bilateral training performance, including kinematic behavior indices, smoothness, submovement and bimanual coordination. After that, we describe the experiments with healthy subjects and the results with respect to these quantitative measures. Feasibility and sensitivity of the proposed indices were evaluated through comparison of unilateral and bilateral training outcomes. The proposed bilateral training system and tasks, as well as the quantitative measures, have been demonstrated effective for training and assessment of unilateral and bilateral arm functions.

  17. Bilateral Trade Flows and Income Distribution Similarity

    Science.gov (United States)

    2016-01-01

    Current models of bilateral trade neglect the effects of income distribution. This paper addresses the issue by accounting for non-homothetic consumer preferences and hence investigating the role of income distribution in the context of the gravity model of trade. A theoretically justified gravity model is estimated for disaggregated trade data (Dollar volume is used as dependent variable) using a sample of 104 exporters and 108 importers for 1980–2003 to achieve two main goals. We define and calculate new measures of income distribution similarity and empirically confirm that greater similarity of income distribution between countries implies more trade. Using distribution-based measures as a proxy for demand similarities in gravity models, we find consistent and robust support for the hypothesis that countries with more similar income-distributions trade more with each other. The hypothesis is also confirmed at disaggregated level for differentiated product categories. PMID:27137462

  18. Integration of fringe projection and two-dimensional digital image correlation for three-dimensional displacements measurements

    Science.gov (United States)

    Felipe-Sesé, Luis; López-Alba, Elías; Siegmann, Philip; Díaz, Francisco A.

    2016-12-01

    A low-cost approach for three-dimensional (3-D) full-field displacement measurement is applied for the analysis of large displacements involved in two different mechanical events. The method is based on a combination of fringe projection and two-dimensional digital image correlation (DIC) techniques. The two techniques have been employed simultaneously using an RGB camera and a color encoding method; therefore, it is possible to measure in-plane and out-of-plane displacements at the same time with only one camera even at high speed rates. The potential of the proposed methodology has been employed for the analysis of large displacements during contact experiments in a soft material block. Displacement results have been successfully compared with those obtained using a 3D-DIC commercial system. Moreover, the analysis of displacements during an impact test on a metal plate was performed to emphasize the application of the methodology for dynamics events. Results show a good level of agreement, highlighting the potential of FP + 2D DIC as low-cost alternative for the analysis of large deformations problems.

  19. Digital temperature meter

    Energy Technology Data Exchange (ETDEWEB)

    Glowacki, S

    1982-01-01

    Digital temperature meter for precise temperature measurements is presented. Its parts such as thermostat, voltage-frequency converter and digital frequency meter are described. Its technical parameters such as temperature range 50degC-700degC, measurement precision 1degC, measurement error +-1degC are given. (A.S.).

  20. [Digital blood flow measurement by venous occlusion plethysmography in Raynaud's phenomenon. Value of the rewarming test].

    Science.gov (United States)

    Cristol, R; Debray, J

    1986-01-01

    The fingertip blood flow measured by mercury strain gauge plethysmography with venous occlusion, at 22 degrees C room temperature, had significantly lower mean values in 190 patients with Raynaud's phenomenon (55 men aged 49 yrs +/- 16, 135 women aged 48 yrs +/- 16) than in 40 age and sex matched controls: 18 ml/100 ml/minute +/- 14.6 versus 35 ml/100 ml/minute +/- 15 at level p less than 0.01. The mean fingertip blood flow was significantly lower (p less than 0.01) in 31 cases of scleroderma and 32 cases of pulpar necrosis (respectively 13 ml +/- 13 and 11 ml +/- 8) than in 55 cases of primary Raynaud's disease (no detectable etiology and normal capillaroscopy 5 years after onset) or in 34 cases of mild Raynaud's phenomenon (respectively 21.6 +/- 16 and 24.4 +/- 18). A warming test (both hands in water at 45 degrees C during 3 minutes) was performed in 50 cases with low basal fingertip blood flow. It induced a "normalized" flow in 22 cases (mostly primary or mild Raynaud), a partly improved flow in 20 cases (mostly secondary Raynaud) and no improvement in 8 cases (scleroderma). The warming test appears to be clinically useful to assess the vasospasm and the vasodilating capabilities.

  1. Prenatal natural history of isolated fetal mild bilateral pyelectasis

    Directory of Open Access Journals (Sweden)

    Gustavo de Paula Pereira

    Full Text Available OBJECTIVE: To analyze the prenatal outcomes in a cohort of fetuses with mild bilateral pyelectasis and determine whether performing serial ultrasounds is a good follow-up strategy. METHODS: A prospective longitudinal study was conducted on 62 fetuses with mild bilateral pyelectasis. Fetal mild bilateral pyelectasis was considered when the renal pelvis measured (in millimeters ≥5.0 to 10.0, ≥7.0 to 10.0, and ≥10.0 to 15 at ≤23 weeks 6 days, 24 to 31 weeks 6 days, and ≥32 weeks, respectively, with no uretero-calyceal dilatation. Ultrasounds were performed every 3 weeks to assess whether the mild bilateral pyelectasis regressed, remained unchanged (Group 1 or progressed (Group 2. RESULTS: Group 1 consisted of 53 fetuses (85.4%, and progression was observed in 9 cases (Group 2, 14.6%. The initial renal pelvis diameter was significantly larger in fetuses with progression (p=0.028. Statistically significant differences in the renal pelvis diameter were also found at weeks 31 and 35 for both kidneys (p<0.05. The cases requiring intrauterine procedures or early delivery were not observed. CONCLUSION: Fetal mild bilateral pyelectasis with no calyceal dilatation is a benign condition that can be managed in the postnatal period. The initial renal pelvis diameter and the diameter in week 31 or 35 were valuable parameters for identifying cases that would eventually need specific postnatal procedures.

  2. Measuring Digital Competence and ICT Literacy: An Exploratory Study of In-Service English Language Teachers in the Context of Saudi Arabia

    Science.gov (United States)

    Al Khateeb, Ahmed Abdulteeef M.

    2017-01-01

    The purpose of this research is to measure in-service English language teachers' digital competence, particularly for the enhancement of teaching English as a second/foreign language in schools in Saudi Arabia. Information and communication technology (ICT) knowledge is currently considered as a vital skill for foreign language teachers in…

  3. Derivation and Cross-Validation of Cutoff Scores for Patients With Schizophrenia Spectrum Disorders on WAIS-IV Digit Span-Based Performance Validity Measures.

    Science.gov (United States)

    Glassmire, David M; Toofanian Ross, Parnian; Kinney, Dominique I; Nitch, Stephen R

    2016-06-01

    Two studies were conducted to identify and cross-validate cutoff scores on the Wechsler Adult Intelligence Scale-Fourth Edition Digit Span-based embedded performance validity (PV) measures for individuals with schizophrenia spectrum disorders. In Study 1, normative scores were identified on Digit Span-embedded PV measures among a sample of patients (n = 84) with schizophrenia spectrum diagnoses who had no known incentive to perform poorly and who put forth valid effort on external PV tests. Previously identified cutoff scores resulted in unacceptable false positive rates and lower cutoff scores were adopted to maintain specificity levels ≥90%. In Study 2, the revised cutoff scores were cross-validated within a sample of schizophrenia spectrum patients (n = 96) committed as incompetent to stand trial. Performance on Digit Span PV measures was significantly related to Full Scale IQ in both studies, indicating the need to consider the intellectual functioning of examinees with psychotic spectrum disorders when interpreting scores on Digit Span PV measures. © The Author(s) 2015.

  4. Reproducibility and accuracy of linear measurements on dental models derived from cone-beam computed tomography compared with digital dental casts

    NARCIS (Netherlands)

    Waard, O. de; Rangel, F.A.; Fudalej, P.S.; Bronkhorst, E.M.; Kuijpers-Jagtman, A.M.; Breuning, K.H.

    2014-01-01

    INTRODUCTION: The aim of this study was to determine the reproducibility and accuracy of linear measurements on 2 types of dental models derived from cone-beam computed tomography (CBCT) scans: CBCT images, and Anatomodels (InVivoDental, San Jose, Calif); these were compared with digital models

  5. Field Strain Measurement on the Fiber Scale in Carbon Fiber Reinforced Polymers Using Global Finite-Element Based Digital Image Correlation

    KAUST Repository

    Tao, Ran

    2015-01-01

    is aimed to accurately measure the displacement and strain fields at the fiber-matrix scale in a cross-ply composite. First, the theories of both local subset-based digital image correlation (DIC) and global finite-element based DIC are outlined. Second, in

  6. Breast Imaging Reporting and Data System (BI-RADS) breast composition descriptors: Automated measurement development for full field digital mammography

    International Nuclear Information System (INIS)

    Fowler, E. E.; Sellers, T. A.; Lu, B.; Heine, J. J.

    2013-01-01

    Purpose: The Breast Imaging Reporting and Data System (BI-RADS) breast composition descriptors are used for standardized mammographic reporting and are assessed visually. This reporting is clinically relevant because breast composition can impact mammographic sensitivity and is a breast cancer risk factor. New techniques are presented and evaluated for generating automated BI-RADS breast composition descriptors using both raw and calibrated full field digital mammography (FFDM) image data.Methods: A matched case-control dataset with FFDM images was used to develop three automated measures for the BI-RADS breast composition descriptors. Histograms of each calibrated mammogram in the percent glandular (pg) representation were processed to create the new BR pg measure. Two previously validated measures of breast density derived from calibrated and raw mammograms were converted to the new BR vc and BR vr measures, respectively. These three measures were compared with the radiologist-reported BI-RADS compositions assessments from the patient records. The authors used two optimization strategies with differential evolution to create these measures: method-1 used breast cancer status; and method-2 matched the reported BI-RADS descriptors. Weighted kappa (κ) analysis was used to assess the agreement between the new measures and the reported measures. Each measure's association with breast cancer was evaluated with odds ratios (ORs) adjusted for body mass index, breast area, and menopausal status. ORs were estimated as per unit increase with 95% confidence intervals.Results: The three BI-RADS measures generated by method-1 had κ between 0.25–0.34. These measures were significantly associated with breast cancer status in the adjusted models: (a) OR = 1.87 (1.34, 2.59) for BR pg ; (b) OR = 1.93 (1.36, 2.74) for BR vc ; and (c) OR = 1.37 (1.05, 1.80) for BR vr . The measures generated by method-2 had κ between 0.42–0.45. Two of these measures were significantly

  7. Bilateral inguinal hernia repair: laparoscopic or open approach?

    Science.gov (United States)

    Feliu, X; Clavería, R; Besora, P; Camps, J; Fernández-Sallent, E; Viñas, X; Abad, J M

    2011-02-01

    The aim of this study was to investigate outcomes in the treatment of bilateral inguinal hernia, comparing the laparoscopic totally extraperitoneal (TEP) and open tension-free mesh repair (LICHT) approaches. We performed a prospective controlled non randomized clinical study in 128 patients with bilateral inguinal hernia over a period of 3 years. LICHT was used in 106 cases (53 patients) while TEP was employed in 150 cases (75 patients). The main outcome measurements were: recurrence rate, operating time, hospital stay and postoperative complications. There were three recurrences (2.3%): two in the LICHT group (3.8%) and one (1.3%) in the TEP group P = NS. The TEP procedure was faster than LICHT repair (48.8 ± 10.8 vs. 70.4 ± 11.2 min) P approach is an effective option for the treatment of bilateral inguinal hernia when performed by experienced surgeons.

  8. Introduction of a Case of Bilateral Pheochromocytoma Tumor

    Directory of Open Access Journals (Sweden)

    M Zare

    2009-01-01

    Full Text Available Summary: Pheochromocytoma is an adrenal tumor characterized by symptoms of hypertension, headache, increased sweating, and tachycardia .In one third of patients, the tumor is discovered incidentally during radiological evaluation of the abdomen. In this article a case of bilateral pheochromocytoma is reported. The patient, a twelve years old boy, referred with complaints of headache, flushing, palpitation and blurring of vision. He had a blood pressure of 200/120 mmHg and after investigation, coarctation of aorta was excluded. On abdominal ultrasound, bilateral adrenal mass was diagnosed, followed by serial measurements of urinary vanillyl mandellic acid (VMA which was found to be elevated. Meta- Iodio benzyl glunidin (MIBG scan showed increased uptake in both adrenals. Patient underwent laparotomy and bilateral adrenalectomy with the diagnosis of pheochromocytoma. Pathologic report confirmed the diagnosis

  9. Effect of acute bilateral adrenalectomy and reserpine on gastric ...

    African Journals Online (AJOL)

    STORAGESEVER

    2008-09-03

    Sep 3, 2008 ... the secretion of gastric mucus in a system where glycoprotein erosion is measured together with adherent mucus secretion in the gastric mucosa in the unstimu- lated state. Therefore, the present study was undertaken to examine the effect of acute bilateral adrenalectomy and dopamine depletory agent ...

  10. Bilateral multiligament injury of knee caused by entangled dupatta

    Directory of Open Access Journals (Sweden)

    Shrinand V Vaidya

    2012-01-01

    Full Text Available We report a rare case of bilateral multiligament knee injury in an 18-year-old female employed in garment industry. Patient was wearing salwar kameez and dupatta while operating an electric laundry machine. In this case we discuss a peculiar mechanism of injury caused due to wearing dupatta near working site and suggest simple preventive measures.

  11. Biomechanics of unilateral and bilateral sacroiliac joint stabilization: laboratory investigation.

    Science.gov (United States)

    Lindsey, Derek P; Parrish, Robin; Gundanna, Mukund; Leasure, Jeremi; Yerby, Scott A; Kondrashov, Dimitriy

    2018-03-01

    OBJECTIVE Bilateral symptoms have been reported in 8%-35% of patients with sacroiliac (SI) joint dysfunction. Stabilization of a single SI joint may significantly alter the stresses on the contralateral SI joint. If the contralateral SI joint stresses are significantly increased, degeneration may occur; alternatively, if the stresses are significantly reduced, bilateral stabilization may be unnecessary for patients with bilateral symptoms. The biomechanical effects of 1) unilateral stabilization on the contralateral SI joint and 2) bilateral stabilization on both SI joints are currently unknown. The objectives of this study were to characterize bilateral SI joint range of motion (ROM) and evaluate and compare the biomechanical effects of unilateral and bilateral implant placement for SI joint fusion. METHODS A lumbopelvic model (L5-pelvis) was used to test the ROM of both SI joints in 8 cadavers. A single-leg stance setup was used to load the lumbar spine and measure the ROM of each SI joint in flexion-extension, lateral bending, and axial rotation. Both joints were tested 1) while intact, 2) after unilateral stabilization, and 3) after bilateral stabilization. Stabilization consisted of lateral transiliac placement of 3 triangular titanium plasma-sprayed (TPS) implants. RESULTS Intact testing showed that during single-leg stance the contralateral SI joint had less ROM in flexion-extension (27%), lateral bending (32%), and axial rotation (69%) than the loaded joint. Unilateral stabilization resulted in significant reduction of flexion-extension ROM (46%) on the treated side; no significant ROM changes were observed for the nontreated side. Bilateral stabilization resulted in significant reduction of flexion-extension ROM of the primary (45%) and secondary (75%) SI joints. CONCLUSIONS This study demonstrated that during single-leg loading the ROMs for the stance (loaded) and swing (unloaded) SI joints are significantly different. Unilateral stabilization for SI

  12. Local liquid velocity measurement in trickle bed reactors (TBRs) using the x-ray digital industrial radiography (DIR) technique

    International Nuclear Information System (INIS)

    Salleh, Khairul Anuar Mohd; Lee, Hyoung Koo; Al-Dahhan, Muthanna H

    2014-01-01

    This work describes the development of a new technique to measure local liquid velocity (V LL ) for multiphase flows in trickle bed reactors (TBRs) (gas–liquid–solid system). In the studied TBR, the liquid phase is represented by water, gas by air and 3 mm expanded polystyrene beads as the solid packing. Three different superficial liquid velocities (V SL ) and a constant superficial gas velocity (V SG ) were used in the packed bed with an internal diameter of 4.25 cm. While the liquid is moving into the packed bed, tracking particles of 106–125 μm diameter (16.45% difference) are injected. The movement of the tracking particles is monitored and digitally recorded by a complementary metal–oxide–semiconductor detector. In this experiment, x-rays were used as the radiation source. Four replications were made with fresh packing. Comparable observations can be found from other published techniques (i.e. magnetic resonance imaging). Results from this study indicate that, at V SL = 0.13 cm s −1 , the measured V LL  can reach up to 51 times that of its V SL , while for V SL = 0.27 cm s −1 , the measured V LL  reached up to 35 times higher than the V SL and for V SL = 0.39 cm s −1 , the V LL  reached up to 39.8 times higher than its V SL . Through statistical analysis, the implementation of such a method is found to be reproducible throughout the experiments. The mean per cent difference in the measured V LL was 10% and 5% for lower implemented V SL   of 0.13 and 0.27 cm s −1 , respectively. At higher V SL  (0.39 cm s −1 ), the particle tracer was greatly distributed and carried away by the high liquid flow rate. The variance or the range of the measured V LL  does not vary for all replications in every V SL , which confirms the reproducibility of the experimental measurements, regardless of the V SL . (paper)

  13. A high-resolution, multi-stop, time-to-digital converter for nuclear time-of-flight measurements

    International Nuclear Information System (INIS)

    Spencer, D.F.; Cole, J.; Drigert, M.; Aryaeinejad, R.

    2006-01-01

    A high-resolution, multi-stop, time-to-digital converter (TDC) was designed and developed to precisely measure the times-of-flight (TOF) of incident neutrons responsible for induced fission and capture reactions on actinide targets. The minimum time resolution is ±1 ns. The TDC design was implemented into a single, dual-wide CAMAC module. The CAMAC bus is used for command and control as well as an alternative data output. A high-speed ECL interface, compatible with LeCroy FERA modules, was also provided for the principle data output path. An Actel high-speed field programmable gate array (FPGA) chip was incorporated with an external oscillator and an internal multiple clock phasing system. This device implemented the majority of the high-speed register functions, the state machine for the FERA interface, and the high-speed counting circuit used for the TDC conversion. An external microcontroller was used to monitor and control system-level changes. In this work we discuss the performance of this TDC module as well as its application

  14. Measurement of the energy spectrum of {sup 252}Cf fission fragments using nuclear track detectors and digital image processing

    Energy Technology Data Exchange (ETDEWEB)

    Espinosa, G.; Golzarri, J. I. [UNAM, Instituto de Fisica, Circuito Exterior, Ciudad Universitaria, 04510 Mexico D. F. (Mexico); Castano, V. M. [UNAM, Centro de Fisica Aplicada y Tecnologia Avanzada, Boulevard Juriquilla 3001, Santiago de Queretaro, 76230 Queretaro (Mexico); Gaso, I. [ININ, Carretera Mexico-Toluca s/n, Ocoyoacac 52750, Estado de Mexico (Mexico); Mena, M.; Segovia, N. [UNAM, Instituto de Geofisica, Circuito de la Investigacion Cientifica, Ciudad Universitaria, 04510 Mexico D. F. (Mexico)

    2010-02-15

    The energy spectrum of {sup 252}Cf fission fragments was measured using nuclear track detectors and digital image analysis system. The detection material was fused silica glass. The detectors were chemically etched in an 8% HF solution. After experimenting with various etching time, it was found that the best resolution of the track diameter distribution was obtained after 30 minutes of etching. Both Gaussian and Lorentzian curves were fit to the track diameter distribution histograms and used to determine the basic parameters of the distribution of the light (N{sub L}) and heavy (N{sub H}) formed peaks and the minimum of the central valley (N{sub V}). Advantages of the method presented here include the fully-automated analysis process, the low cost of the nuclear track detectors and the simplicity of the nuclear track method. The distribution resolution obtained by this method is comparable with the resolution obtained by electronic analysis devices. The descriptive variables calculated were very close to those obtained by other methods based on the use of semiconductor detectors. (Author)

  15. Development of a universal measure of quadrupedal forelimb-hindlimb coordination using digital motion capture and computerised analysis

    Directory of Open Access Journals (Sweden)

    Jeffery Nick D

    2007-09-01

    Full Text Available Abstract Background Clinical spinal cord injury in domestic dogs provides a model population in which to test the efficacy of putative therapeutic interventions for human spinal cord injury. To achieve this potential a robust method of functional analysis is required so that statistical comparison of numerical data derived from treated and control animals can be achieved. Results In this study we describe the use of digital motion capture equipment combined with mathematical analysis to derive a simple quantitative parameter – 'the mean diagonal coupling interval' – to describe coordination between forelimb and hindlimb movement. In normal dogs this parameter is independent of size, conformation, speed of walking or gait pattern. We show here that mean diagonal coupling interval is highly sensitive to alterations in forelimb-hindlimb coordination in dogs that have suffered spinal cord injury, and can be accurately quantified, but is unaffected by orthopaedic perturbations of gait. Conclusion Mean diagonal coupling interval is an easily derived, highly robust measurement that provides an ideal method to compare the functional effect of therapeutic interventions after spinal cord injury in quadrupeds.

  16. Binaural enhancement for bilateral cochlear implant users.

    Science.gov (United States)

    Brown, Christopher A

    2014-01-01

    Bilateral cochlear implant (BCI) users receive limited binaural cues and, thus, show little improvement to speech intelligibility from spatial cues. The feasibility of a method for enhancing the binaural cues available to BCI users is investigated. This involved extending interaural differences of levels, which typically are restricted to high frequencies, into the low-frequency region. Speech intelligibility was measured in BCI users listening over headphones and with direct stimulation, with a target talker presented to one side of the head in the presence of a masker talker on the other side. Spatial separation was achieved by applying either naturally occurring binaural cues or enhanced cues. In this listening configuration, BCI patients showed greater speech intelligibility with the enhanced binaural cues than with naturally occurring binaural cues. In some situations, it is possible for BCI users to achieve greater speech intelligibility when binaural cues are enhanced by applying interaural differences of levels in the low-frequency region.

  17. Bilateral absence of musculocutaneous nerve

    Directory of Open Access Journals (Sweden)

    Mathada V Ravishankar

    2012-01-01

    Full Text Available Brachial plexus is an important group of spinal nerve plexus that supplies the muscles of the upper limb via the ventral rami of the Cervical 5 - Thoracic 1 fibers of the spinal nerves. It is not uncommon to notice the variations during cadaveric dissections in many regions of the body, at different levels, such as, roots, trunks, division, cords, communications, and branches as reported in the literature. Although the nerve supply of the body musculature takes place in the fetal life itself, its course, branching pattern, innervations, and communication can show variable patterns as the fetal development progresses. One such anomaly was noticed during our routine cadaveric dissection in the Department of Anatomy, Jawaharlal Nehru Medical College, Belgaum, showing bilateral absence of the musculocutaneous nerve, which obviously drew the attention of the students of medicine, physiotherapy, and learning clinicians as well.

  18. Bilateral supernumerary primary maxillary canines

    Directory of Open Access Journals (Sweden)

    Santanu Mukhopadhyay

    2018-01-01

    Full Text Available Supernumerary teeth are more common in the permanent than in primary dentition. In the primary dentition, the anomaly is most frequently observed in the maxillary lateral incisor region, followed by the maxillary midline where they are termed as mesiodens. Supernumerary teeth in the primary canine region are rare. This paper describes a rare case of nonsyndromic supernumerary primary maxillary canine distributed bilaterally in a 4-year-old boy. Both the supernumeraries resembled size and shape of normal primary canine. The right supplemental canine is high labially placed, whereas the left one is seen normally aligned in the dental arch distal to lateral incisor. One of the most significant sequelae of primary supernumerary teeth is their duplication in the permanent series. Radiographic examination of supernumerary primary canine did not indicate any such anomaly in the permanent dentition. The patient was kept under observation.

  19. Voxel effects within digital images of trabecular bone and their consequences on chord-length distribution measurements

    International Nuclear Information System (INIS)

    Rajon, D.A.; Shah, A.P.; Watchman, C.J.; Bolch, W.E.; Jokisch, D.W.; Patton, P.W.

    2002-01-01

    Chord-length distributions through the trabecular regions of the skeleton have been investigated since the early 1960s. These distributions have become important features for bone marrow dosimetry; as such, current models rely on the accuracy of their measurements. Recent techniques utilize nuclear magnetic resonance (NMR) microscopy to acquire 3D images of trabecular bone that are then used to measure 3D chord-length distributions by Monte Carlo methods. Previous studies have shown that two voxel effects largely affect the acquisition of these distributions within digital images. One is particularly pertinent as it dramatically changes the shape of the distribution and reduces its mean. An attempt was made to reduce this undesirable effect and good results were obtained for a single-sphere model using minimum acceptable chord (MAC) methods (Jokisch et al 2001 Med. Phys. 28 1493-504). The goal of the present work is to extend the study of these methods to more general models in order to better quantify their consequences. First, a mathematical model of a trabecular bone sample was used to test the usefulness of the MAC methods. The results showed that these methods were not efficient for this simulated bone model. These methods were further tested on a single voxelized sphere over a large range of voxel sizes. The results showed that the MAC methods are voxel-size dependent and overestimate the mean chord length for typical resolutions used with NMR microscopy. The study further suggests that bone and marrow chord-length distributions currently utilized in skeletal dosimetry models are most likely affected by voxel effects that yield values of mean chord length lower than their true values. (author)

  20. COMBATING DIGITAL PIRACY IN NIGERIA. AN ANALYSIS OF TECHNOLOGICAL PROTECTIVE MEASURES AND RIGHTS MANAGEMENT INFORMATION UNDER THE COPYRIGHT BILL

    OpenAIRE

    Kuti, Aishat Obadunni

    2016-01-01

    The adoption of digital technologies and creation of global internet infrastructure for the vast array of companies and individuals offering products and services that leverage its connectivity has transformed our world over the past two decades. The Internet has grown from a resource platform for individuals to an essential omnichannel medium for more than 2 billion users worldwide and with each facet of growth comes unprecedented challenges. The impact of digital technology on Nigerian crea...

  1. BILATERAL PATHOLOGICAL HIP DISLOCATION IN CHILDREN

    Directory of Open Access Journals (Sweden)

    Yuriy E. Garkavenko

    2017-03-01

    Full Text Available Introduction. Pathological dislocation of the hip is one of the most severe complications of acute hematogenous osteomyelitis. The program of treatment for children with pathological hip dislocation is complex, but it has been sufficiently developed and implemented very successfully. At the same time, the available literature provides no cases of treating children with bilateral pathological hip dislocations after hematogenous osteomyelitis. There is no information on the incidence of such cases or in regards to remote functional results. Materials and methods. The results of the treatment of 18 children with bilateral pathological dislocation of the hip after hematogenous osteomyelitis are presented, which constituted 23.1% of the total number of patients (78 who underwent surgery in 2000–2016 for the diagnosis of pathological hip dislocation. Both hip joints were surgically operated on in 12 patients, while one hip joint was operated on in 6 patients. To assess the anatomical and functional state of hip joints, the clinical and roentgenological diagnostic techniques were used. Results and discussion. To stabilize and restore the function of the hip joints, 18 children underwent 30 surgical interventions: simple open hip reduction (19 and open hip reduction with hip arthroplasty with one (6 or two (5 demineralized osteochondral allogeneic grafts. The decision regarding the possibility of performing surgical intervention on the second hip joint was made only after a child's check-up examination was complete and after positive information about the anatomical and functional state of the operated hip joint was obtained. According to these criteria, 14 (77.8% children underwent surgical treatment of the second hip joint 1–1.5 years after the course of conservative measures to restore the range of motion in the previously operated hip joint. Over a period of 1–12 years, 17 patients were examined, 10 of which underwent an operation on both

  2. The Accuracy of the Digital imaging system and the frequency dependent type apex locator in root canal length measurement

    International Nuclear Information System (INIS)

    Lee, Byoung Rib; Park, Chang Seo

    1998-01-01

    In order to achieve a successful endodontic treatment, root canals must be obturated three-dimensionally without causing any damage to apical tissues. Accurate length determination of the root canal is critical in this case. For this reason, I've used the conventional periapical radiography, Digora (digital imaging system) and Root ZX (the frequency dependent type apex locator) to measure the length of the canal and compare it with the true length obtained by cutting the tooth in half and measuring the length between the occlusal surface and the apical foramen. From the information obtained by these measurements, I was able to evaluate the accuracy and clinical usefulness of each systems, whether the thickness of files used in endodontic therapy has any effect on the measuring systems was also evaluated in an effort to simplify the treatment planning phase of endodontic treatment. 29 canals of 29 sound premolars were measured with no 15, no 20, no 25 files by 3 different dentists each using the periapical radiography, Digora and Root ZX. The measurements were then compared with the true length. The results were as follows ; 1. In comparing mean discrepancies between measurements obtained by using periapical radiography (mean error : -0.449 ± 0.444 mm), Digora (mean error : -0.417 ± 0.415 mm) and Root ZX (mean error : 0.123 ± 0.458 mm) with true length, periapical radiography and Digora system had statistically significant differences (p 0.05). 2. By subtracting values obtained by using periapical radiography, Digora and Root ZX from the true length and making a distribution table of their absolute values, the following analysis was possible. In the case of periapical film, 140 out of 261 (53.6%) were clinically acceptable satisfying the margin of error of less than 0.5 mm, 151 out of 261 (53,6%) were acceptable in the Digora system while Root ZX had 197 out of 261 (75.5%) within the limits of 0.5 mm margin of error. 3. In determining whether the thickness of

  3. A Rare Entity: Bilateral First Rib Fractures Accompanying Bilateral Scapular Fractures

    Directory of Open Access Journals (Sweden)

    Gultekin Gulbahar

    2015-01-01

    Full Text Available First rib fractures are scarce due to their well-protected anatomic locations. Bilateral first rib fractures accompanying bilateral scapular fractures are very rare, although they may be together with scapular and clavicular fractures. According to our knowledge, no case of bilateral first rib fractures accompanying bilateral scapular fractures has been reported, so we herein discussed the diagnosis, treatment, and complications of bone fractures due to thoracic trauma in bias of this rare entity.

  4. A Rare Entity: Bilateral First Rib Fractures Accompanying Bilateral Scapular Fractures

    OpenAIRE

    Gulbahar, Gultekin; Kaplan, Tevfik; Turker, Hasan Bozkurt; Gundogdu, Ahmet Gokhan; Han, Serdar

    2015-01-01

    First rib fractures are scarce due to their well-protected anatomic locations. Bilateral first rib fractures accompanying bilateral scapular fractures are very rare, although they may be together with scapular and clavicular fractures. According to our knowledge, no case of bilateral first rib fractures accompanying bilateral scapular fractures has been reported, so we herein discussed the diagnosis, treatment, and complications of bone fractures due to thoracic trauma in bias of this rare en...

  5. A Rare Entity: Bilateral First Rib Fractures Accompanying Bilateral Scapular Fractures.

    Science.gov (United States)

    Gulbahar, Gultekin; Kaplan, Tevfik; Turker, Hasan Bozkurt; Gundogdu, Ahmet Gokhan; Han, Serdar

    2015-01-01

    First rib fractures are scarce due to their well-protected anatomic locations. Bilateral first rib fractures accompanying bilateral scapular fractures are very rare, although they may be together with scapular and clavicular fractures. According to our knowledge, no case of bilateral first rib fractures accompanying bilateral scapular fractures has been reported, so we herein discussed the diagnosis, treatment, and complications of bone fractures due to thoracic trauma in bias of this rare entity.

  6. X-ray digital industrial radiography (DIR) for local liquid velocity (V{sub LL}) measurement in trickle bed reactors (TBRs): Validation of the technique

    Energy Technology Data Exchange (ETDEWEB)

    Mohd Salleh, Khairul Anuar, E-mail: kmfgf@mst.edu; Lee, Hyoung Koo [Department of Mining and Nuclear Engineering, Missouri University of Science and Technology, Fulton Hall, 310 W. 14th St., Rolla, Missouri 65409 (United States); Rahman, Mohd Fitri Abdul [Department of Chemical and Biochemical Engineering, Missouri University of Science and Technology, 143 Schrenk Hall, 400 W. 11th St., Rolla, Missouri 65409 (United States); Al Dahhan, Muthanna H. [Department of Mining and Nuclear Engineering, Missouri University of Science and Technology, Fulton Hall, 310 W. 14th St., Rolla, Missouri 65409 (United States); Department of Chemical and Biochemical Engineering, Missouri University of Science and Technology, 143 Schrenk Hall, 400 W. 11th St., Rolla, Missouri 65409 (United States)

    2014-06-15

    Local liquid velocity measurements in Trickle Bed Reactors (TBRs) are one of the essential components in its hydrodynamic studies. These measurements are used to effectively determine a reactor's operating condition. This study was conducted to validate a newly developed technique that combines Digital Industrial Radiography (DIR) with Particle Tracking Velocimetry (PTV) to measure the Local Liquid Velocity (V{sub LL}) inside TBRs. Three millimeter-sized Expanded Polystyrene (EPS) beads were used as packing material. Three validation procedures were designed to test the newly developed technique. All procedures and statistical approaches provided strong evidence that the technique can be used to measure the V{sub LL} within TBRs.

  7. X-ray digital industrial radiography (DIR) for local liquid velocity (VLL) measurement in trickle bed reactors (TBRs): Validation of the technique

    Science.gov (United States)

    Mohd Salleh, Khairul Anuar; Rahman, Mohd Fitri Abdul; Lee, Hyoung Koo; Al Dahhan, Muthanna H.

    2014-06-01

    Local liquid velocity measurements in Trickle Bed Reactors (TBRs) are one of the essential components in its hydrodynamic studies. These measurements are used to effectively determine a reactor's operating condition. This study was conducted to validate a newly developed technique that combines Digital Industrial Radiography (DIR) with Particle Tracking Velocimetry (PTV) to measure the Local Liquid Velocity (VLL) inside TBRs. Three millimeter-sized Expanded Polystyrene (EPS) beads were used as packing material. Three validation procedures were designed to test the newly developed technique. All procedures and statistical approaches provided strong evidence that the technique can be used to measure the VLL within TBRs.

  8. X-ray digital industrial radiography (DIR) for local liquid velocity (VLL) measurement in trickle bed reactors (TBRs): Validation of the technique

    International Nuclear Information System (INIS)

    Mohd Salleh, Khairul Anuar; Lee, Hyoung Koo; Rahman, Mohd Fitri Abdul; Al Dahhan, Muthanna H.

    2014-01-01

    Local liquid velocity measurements in Trickle Bed Reactors (TBRs) are one of the essential components in its hydrodynamic studies. These measurements are used to effectively determine a reactor's operating condition. This study was conducted to validate a newly developed technique that combines Digital Industrial Radiography (DIR) with Particle Tracking Velocimetry (PTV) to measure the Local Liquid Velocity (V LL ) inside TBRs. Three millimeter-sized Expanded Polystyrene (EPS) beads were used as packing material. Three validation procedures were designed to test the newly developed technique. All procedures and statistical approaches provided strong evidence that the technique can be used to measure the V LL within TBRs

  9. X-ray digital industrial radiography (DIR) for local liquid velocity (V(LL)) measurement in trickle bed reactors (TBRs): validation of the technique.

    Science.gov (United States)

    Mohd Salleh, Khairul Anuar; Rahman, Mohd Fitri Abdul; Lee, Hyoung Koo; Al Dahhan, Muthanna H

    2014-06-01

    Local liquid velocity measurements in Trickle Bed Reactors (TBRs) are one of the essential components in its hydrodynamic studies. These measurements are used to effectively determine a reactor's operating condition. This study was conducted to validate a newly developed technique that combines Digital Industrial Radiography (DIR) with Particle Tracking Velocimetry (PTV) to measure the Local Liquid Velocity (V(LL)) inside TBRs. Three millimeter-sized Expanded Polystyrene (EPS) beads were used as packing material. Three validation procedures were designed to test the newly developed technique. All procedures and statistical approaches provided strong evidence that the technique can be used to measure the V(LL) within TBRs.

  10. The use of digital image speckle correlation to measure the mechanical properties of skin and facial muscular activity

    Science.gov (United States)

    Staloff, Isabelle Afriat

    Skin mechanical properties have been extensively studied and have led to an understanding of the structure and role of the collagen and elastin fibers network in the dermis and their changes due to aging. All these techniques have either isolated the skin from its natural environment (in vitro), or, when studied in vivo, attempted to minimize the effect of the underlying tissues and muscles. The human facial region is unique compared to the other parts of the body in that the underlying musculature runs through the subcutaneous tissue and is directly connected to the dermis with collagen based fibrous tissues. These fibrous tissues comprise the superficial musculoaponeurotic system, commonly referred to as the SMAS layer. Retaining ligaments anchor the skin to the periosteum, and hold the dermis to the SMAS. In addition, traditional techniques generally collect an average response of the skin. Data gathered in this manner is incomplete as the skin is anisotropic and under constant tension. We therefore introduce the Digital Image Speckle Correlation (DISC) method that maps in two dimensions the skin deformation under the complex set of forces involved during muscular activity. DISC, a non-contact in vivo technique, generates spatial resolved information. By observing the detailed motion of the facial skin we can infer the manner in which the complex ensemble of forces induced by movement of the muscles distribute and dissipate on the skin. By analyzing the effect of aging on the distribution of these complex forces we can measure its impact on skin elasticity and quantify the efficacy of skin care products. In addition, we speculate on the mechanism of wrinkle formation. Furthermore, we investigate the use of DISC to map the mechanism of film formation on skin of various polymers. Finally, we show that DISC can detect the involuntary facial muscular activity induced by various fragrances.

  11. Effects of voice timbre and accompaniment on working memory as measured by sequential monosyllabic digit recall performance.

    Science.gov (United States)

    Silverman, Michael J; Schwartzberg, Edward T

    2014-01-01

    Information is often paired with music in an attempt to facilitate recall and enhance learning. However, there is a lack of basic research investigating how music carrying information might facilitate recall and subsequent learning. The purpose of the current study was to determine the effects of voice timbre and accompaniment on working memory as measured by recall performance on a sequential digit recall task. Specific research questions were as follows: (a) How might female and male voice timbres affect serial recall? (b) How might piano, guitar, and no accompaniment affect serial recall? (c) Do music majors have enhanced recall accuracy when compared to nonmusic majors? The recall of information paired with six different melodies was tested on 60 university students. Melodies were composed and recorded using female and male voices with three levels of accompaniment: guitar, piano, and no accompaniment. Participants had more accurate recall during the male voice and piano and no accompaniment conditions and least accurate recall during the female voice and guitar accompaniment conditions. As participants had most accurate recall during the male voice and with piano or no accompaniment, clinicians are encouraged to consider using no accompaniment or piano accompaniment when initially teaching social and academic information paired with music for later recall. When possible, vocal timbre (i.e., the potential benefit of male voicing) should also be considered. Implications for clinical practice, limitations of the study, and suggestions for future research are provided. © the American Music Therapy Association 2014. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  12. Bilateral Simultaneous Macular Infarction with Spontaneous Visual ...

    African Journals Online (AJOL)

    To report the rare and dramatic event of bilateral macular infarction in a sickle cell hemoglobinopathy (SS genotype) patient, resulting in bilateral severe reduction in visual acuity. Without any intervention, the patient's vision gradually improved over the follow‑up period. Central visual field defects however persisted.

  13. Bilateral microperc in a severe kyphoscoliosis

    OpenAIRE

    Dağgülli, Mansur; Penbegül, Necmettin; Dede, Onur; Utanğaç, Mehmet Mazhar

    2016-01-01

    Percutaneous nephrolithotomy is the standard modality for large renal calculi in normal and abnormal renal anatomic situations. This case report describes a 57-year-old male patient who presented with bilateral kidney stones and severe kyphoscoliosis. He had successfully been treated with a bilateral microperc technique.

  14. Infectious mononucleosis presenting as bilateral acute dacryocystitis.

    Science.gov (United States)

    Atkinson, P L; Ansons, A M; Patterson, A

    1990-01-01

    A case of infectious mononucleosis presenting as bilateral acute dacryocystitis in a 7-year-old girl is reported. Acute dacryocystitis is uncommon in this age group, and an underlying systemic illness should be suspected particularly when it is bilateral. Images PMID:2275940

  15. Bilateral elastofibroma dorsi: A case report

    OpenAIRE

    Molini, L.; Ciortan, E.; Bianchi, S.

    2010-01-01

    Elastofibroma dorsi is a rare pseudotumoral lesion located in the periscapular region. Ultrasound can be used to evaluate its dimensions, margins, and internal structure. In the presence of bilateralism, diagnosis can be made on the basis of clinical and sonographic findings. The authors present a case of bilateral elastofibroma dorsi in which the clinical and ultrasound diagnosis was confirmed by magnetic resonance imaging.

  16. Bilateral locked facets in the thoracic spine

    NARCIS (Netherlands)

    M.H.A. Willems; Braakman, R. (Reinder); B. van Linge (Bert)

    1984-01-01

    textabstractTwo cases of traumatic bilateral locked facets in the thoracic spine are reported. Both patients had only minor neurological signs. They both made a full neurological recovery after surgical reduction of the locked facets. Bilateral locked facets are very uncommon in the thoracic spine.

  17. Bilateral spontaneous adrenal haemorrhage complicating acute pancreatitis

    International Nuclear Information System (INIS)

    Pianta, M.; Varma, D. K.

    2007-01-01

    Bilateral adrenal haemorrhage is an event that mandates prompt diagnosis and treatment to prevent primary adrenocortical insufficiency and potential death. Presentation can be non-specific and incidentally diagnosed with imaging alone, primarily CT. We present a case of acute pancreatitis with spontaneous bilateral adrenal haemorrhage and briefly discuss imaging and treatment implications

  18. A case of bilateral trench foot.

    Science.gov (United States)

    Parsons, S L; Leach, I H; Charnley, R M

    1993-12-01

    A case of severe bilateral trench foot is presented in a patient who lived rough for 3 weeks without removing his boots. Non-operative management yielded no clinical improvement and bilateral below-knee amputation was necessary. Histology revealed subcutaneous and muscle necrosis with secondary arterial thrombosis.

  19. Evaluation of the intercanine distance in newborns with cleft lip and palate using 3D digital casts

    Directory of Open Access Journals (Sweden)

    Bianca Zeponi Fernandes Mello

    2013-09-01

    Full Text Available OBJECTIVE: The purpose of this present study was to compare, by means of 3D digital casts, the anterior transverse dimension of the dental arch of newborns with and without cleft lip and palate. MATERIAL AND METHODS: The sample was composed of ninety-four children aged from 3 to 9 months divided into three study groups: Group I - children without craniofacial deformities (control group; Group II - children with unilateral cleft lip and palate; Group III - children with bilateral cleft lip and palate. Impressions were executed before lip and palate repair in patients with clefts. Dental casts were digitized using a 3D scanner linked to a computer. Measurements of the intercanine distance were measured on the digital casts. Intergroup comparisons were performed using ANOVA (p<0.05. RESULTS: The results showed a mean of 36.5 mm for unilateral cleft lip and palate group, 34.8 mm for bilateral cleft lip and palate group and 27.52 mm for the control group. There was a statistically significant difference between the control group and both groups of patients with cleft lip and palate. There was no statistically significant difference between complete unilateral and bilateral cleft lip and palate groups. CONCLUSIONS: Patients with complete cleft lip and palate were born with an increased anterior dimension of the maxillary dental arch compared to non cleft patients.

  20. Evaluation of the intercanine distance in newborns with cleft lip and palate using 3D digital casts

    Science.gov (United States)

    MELLO, Bianca Zeponi Fernandes; FERNANDES, Viviane Mendes; CARRARA, Cleide Felício Carvalho; MACHADO, Maria Aparecida Andrade Moreira; GARIB, Daniela Gamba; OLIVEIRA, Thais Marchini

    2013-01-01

    Objective The purpose of this present study was to compare, by means of 3D digital casts, the anterior transverse dimension of the dental arch of newborns with and without cleft lip and palate. Material and Methods The sample was composed of ninety-four children aged from 3 to 9 months divided into three study groups: Group I - children without craniofacial deformities (control group); Group II - children with unilateral cleft lip and palate; Group III - children with bilateral cleft lip and palate. Impressions were executed before lip and palate repair in patients with clefts. Dental casts were digitized using a 3D scanner linked to a computer. Measurements of the intercanine distance were measured on the digital casts. Intergroup comparisons were performed using ANOVA (p<0.05). Results The results showed a mean of 36.5 mm for unilateral cleft lip and palate group, 34.8 mm for bilateral cleft lip and palate group and 27.52 mm for the control group. There was a statistically significant difference between the control group and both groups of patients with cleft lip and palate. There was no statistically significant difference between complete unilateral and bilateral cleft lip and palate groups. Conclusions Patients with complete cleft lip and palate were born with an increased anterior dimension of the maxillary dental arch compared to non cleft patients. PMID:24212990