WorldWideScience

Sample records for bilateral digit measurements

  1. Does crossover innervation really affect the clinical outcome? A comparison of outcome between unilateral and bilateral digital nerve repair

    Directory of Open Access Journals (Sweden)

    Melike Oruç

    2016-01-01

    Full Text Available Digital nerve injuries are the mostly detected nerve injury in the upper extremity. However, since the clinical phenomenon of crossover innervation at some degree from uninjured digital nerve to the injured side occurs after digital nerve injuries is sustained, one could argue that this concept might even result in the overestimation of the outcome of the digital nerve repair. With this knowledge in mind, this study aimed to present novel, pure, focused and valuable clinical data by comparing the outcomes of bilateral and unilateral digital nerve repair. A retrospective review of 28 fingers with unilateral or bilateral digital nerve repair using end-to-end technique in 19 patients within 2 years was performed. Weber′s two-point discrimination, sharp/dull discrimination, warm/cold sensation and Visual Analog Scale scoring were measured at final 12-month follow ups in all patients. There was no significant difference in recovery of sensibility after unilateral and bilateral digital nerve repairs. Though there is crossover innervation microscopically, it is not important in the clinical evaluation period. According to clinical findings from this study, crossover innervations appear to be negligible in the estimation of outcomes of digital neurorrhaphy.

  2. A Digital Image Denoising Algorithm Based on Gaussian Filtering and Bilateral Filtering

    Directory of Open Access Journals (Sweden)

    Piao Weiying

    2018-01-01

    Full Text Available Bilateral filtering has been applied in the area of digital image processing widely, but in the high gradient region of the image, bilateral filtering may generate staircase effect. Bilateral filtering can be regarded as one particular form of local mode filtering, according to above analysis, an mixed image de-noising algorithm is proposed based on Gaussian filter and bilateral filtering. First of all, it uses Gaussian filter to filtrate the noise image and get the reference image, then to take both the reference image and noise image as the input for range kernel function of bilateral filter. The reference image can provide the image’s low frequency information, and noise image can provide image’s high frequency information. Through the competitive experiment on both the method in this paper and traditional bilateral filtering, the experimental result showed that the mixed de-noising algorithm can effectively overcome staircase effect, and the filtrated image was more smooth, its textural features was also more close to the original image, and it can achieve higher PSNR value, but the amount of calculation of above two algorithms are basically the same.

  3. A novel computed method to reconstruct the bilateral digital interarticular channel of atlas and its use on the anterior upper cervical screw fixation

    Directory of Open Access Journals (Sweden)

    Ai-Min Wu

    2016-02-01

    Full Text Available Purpose. To investigate a novel computed method to reconstruct the bilateral digital interarticular channel of atlas and its potential use on the anterior upper cervical screw fixation. Methods. We have used the reverse engineering software (image-processing software and computer-aided design software to create the approximate and optimal digital interarticular channel of atlas for 60 participants. Angles of channels, diameters of inscribed circles, long and short axes of ellipses were measured and recorded, and gender-specific analysis was also performed. Results. The channels provided sufficient space for one or two screws, and the parameters of channels are described. While the channels of females were smaller than that of males, no significant difference of angles between males and females were observed. Conclusion. Our study demonstrates the radiological features of approximate digital interarticular channels, optimal digital interarticular channels of atlas, and provides the reference trajectory of anterior transarticular screws and anterior occiput-to-axis screws. Additionally, we provide a protocol that can help make a pre-operative plan for accurate placement of anterior transarticular screws and anterior occiput-to-axis screws.

  4. Multiscale bilateral filtering for improving image quality in digital breast tomosynthesis

    Science.gov (United States)

    Lu, Yao; Chan, Heang-Ping; Wei, Jun; Hadjiiski, Lubomir M.; Samala, Ravi K.

    2015-01-01

    Purpose: Detection of subtle microcalcifications in digital breast tomosynthesis (DBT) is a challenging task because of the large, noisy DBT volume. It is important to enhance the contrast-to-noise ratio (CNR) of microcalcifications in DBT reconstruction. Most regularization methods depend on local gradient and may treat the ill-defined margins or subtle spiculations of masses and subtle microcalcifications as noise because of their small gradient. The authors developed a new multiscale bilateral filtering (MSBF) regularization method for the simultaneous algebraic reconstruction technique (SART) to improve the CNR of microcalcifications without compromising the quality of masses. Methods: The MSBF exploits a multiscale structure of DBT images to suppress noise and selectively enhance high frequency structures. At the end of each SART iteration, every DBT slice is decomposed into several frequency bands via Laplacian pyramid decomposition. No regularization is applied to the low frequency bands so that subtle edges of masses and structured background are preserved. Bilateral filtering is applied to the high frequency bands to enhance microcalcifications while suppressing noise. The regularized DBT images are used for updating in the next SART iteration. The new MSBF method was compared with the nonconvex total p-variation (TpV) method for noise regularization with SART. A GE GEN2 prototype DBT system was used for acquisition of projections at 21 angles in 3° increments over a ±30° range. The reconstruction image quality with no regularization (NR) and that with the two regularization methods were compared using the DBT scans of a heterogeneous breast phantom and several human subjects with masses and microcalcifications. The CNR and the full width at half maximum (FWHM) of the line profiles of microcalcifications and across the spiculations within their in-focus DBT slices were used as image quality measures. Results: The MSBF method reduced contouring artifacts

  5. Single-lens 3D digital image correlation system based on a bilateral telecentric lens and a bi-prism: validation and application.

    Science.gov (United States)

    Wu, Lifu; Zhu, Jianguo; Xie, Huimin

    2015-09-10

    By using the principle of stereovision, 3D digital image correlation (3D-DIC) can determine the 3D morphology and deformation of a target and has been widely used in experimental mechanics as a noncontact 3D measurement technique. To eliminate the limitations of the conventional 3D-DIC system, this study proposes a calibration-free single-lens 3D-DIC system based on a bilateral telecentric lens and a bi-prism. The performance of the proposed system is verified by tests of rigid-body translation along the out-of-plane direction. As a comparison, the same rigid-body translations are measured using a single-entocentric-lens 3D-DIC system. The results show that the measurement accuracy of the proposed system is higher than that of the entocentric-lens-based one. As an application, the proposed system is used to measure the thermal linear expansion of a ceramic plate at elevated temperatures. The reasonable measurement results verify its applicability in deformation measurements, even in high-temperature environments.

  6. Bilateral Medial Medullary Infarction with Nondominant Vertebral Artery Occlusion.

    Science.gov (United States)

    Zhang, Lei; Zhang, Gui-lian; Du, Ju-mei; Ma, Zhu-lin

    2015-09-01

    Bilateral medial medullary infarction (MMI) is a rare stroke subtype. Here, we report a case with bilateral MMI caused by nondominant vertebral artery occlusion confirmed by brain digital subtraction angiography and magnetic resonance imaging basi-parallel-anatomical-scanning. We highlight that anterior spinal arteries could originate from a unilateral vertebral artery (VA). Radiologists and neurologists should pay attention to the nondominant VA as bilateral MMI may be induced by occlusion of nondominant VA that supplies the bilateral anteromedial territories of the medulla. Copyright © 2015 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  7. Measuring digit lengths with 3D digital stereophotogrammetry: A comparison across methods.

    Science.gov (United States)

    Gremba, Allison; Weinberg, Seth M

    2018-05-09

    We compared digital 3D stereophotogrammetry to more traditional measurement methods (direct anthropometry and 2D scanning) to capture digit lengths and ratios. The length of the second and fourth digits was measured by each method and the second-to-fourth ratio was calculated. For each digit measurement, intraobserver agreement was calculated for each of the three collection methods. Further, measurements from the three methods were compared directly to one another. Agreement statistics included the intraclass correlation coefficient (ICC) and technical error of measurement (TEM). Intraobserver agreement statistics for the digit length measurements were high for all three methods; ICC values exceeded 0.97 and TEM values were below 1 mm. For digit ratio, intraobserver agreement was also acceptable for all methods, with direct anthropometry exhibiting lower agreement (ICC = 0.87) compared to indirect methods. For the comparison across methods, the overall agreement was high for digit length measurements (ICC values ranging from 0.93 to 0.98; TEM values below 2 mm). For digit ratios, high agreement was observed between the two indirect methods (ICC = 0.93), whereas indirect methods showed lower agreement when compared to direct anthropometry (ICC < 0.75). Digit measurements and derived ratios from 3D stereophotogrammetry showed high intraobserver agreement (similar to more traditional methods) suggesting that landmarks could be placed reliably on 3D hand surface images. While digit length measurements were found to be comparable across all three methods, ratios derived from direct anthropometry tended to be higher than those calculated indirectly from 2D or 3D images. © 2018 Wiley Periodicals, Inc.

  8. A longitudinal study of the bilateral benefit in children with bilateral cochlear implants.

    Science.gov (United States)

    Asp, Filip; Mäki-Torkko, Elina; Karltorp, Eva; Harder, Henrik; Hergils, Leif; Eskilsson, Gunnar; Stenfelt, Stefan

    2015-02-01

    To study the development of the bilateral benefit in children using bilateral cochlear implants by measurements of speech recognition and sound localization. Bilateral and unilateral speech recognition in quiet, in multi-source noise, and horizontal sound localization was measured at three occasions during a two-year period, without controlling for age or implant experience. Longitudinal and cross-sectional analyses were performed. Results were compared to cross-sectional data from children with normal hearing. Seventy-eight children aged 5.1-11.9 years, with a mean bilateral cochlear implant experience of 3.3 years and a mean age of 7.8 years, at inclusion in the study. Thirty children with normal hearing aged 4.8-9.0 years provided normative data. For children with cochlear implants, bilateral and unilateral speech recognition in quiet was comparable whereas a bilateral benefit for speech recognition in noise and sound localization was found at all three test occasions. Absolute performance was lower than in children with normal hearing. Early bilateral implantation facilitated sound localization. A bilateral benefit for speech recognition in noise and sound localization continues to exist over time for children with bilateral cochlear implants, but no relative improvement is found after three years of bilateral cochlear implant experience.

  9. Saddle-nose and bilateral cauliflower ear deformities with pyoderma gangrenosum-like ulcers, cavitary pulmonary lesions, digital gangrene and pulselessness in a young female.

    Science.gov (United States)

    Subhadarshani, Sweta; Gupta, Vishal; Chahal, Anurag; Verma, Kaushal K

    2017-06-15

    We report a young female who presented with saddle-nose and bilateral cauliflower ear deformities along with pyoderma gangrenosum-like ulcers, digital gangrene and pulselessness. Subsequently, she was found to have bilateral conductive hearing loss, a corneal opacity, mild aortic regurgitation and radiological evidence of cavitary changes in lungs and aortoarteritis. Our patient had a constellation of symptoms which posed a diagnostic challenge. Finally, a diagnosis of relapsing polychondritis with several unusual features was made. Overlap with Takayasu's arteritis and granulomatosis with polyangitis, which has been reported rarely in the literature, cannot be excluded. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  10. Bilateral Comparison CIEMAT-CENTIS-DMR for radionuclide activity measurements

    International Nuclear Information System (INIS)

    Oropesa Verdecia, P.; Garcia-Torano, E.

    2004-01-01

    We present the results of a bilateral comparison of radionuclide activity measurements between the Radionuclide Metrology Department of the Center of Isotopes of Cuba (CENTIS-DMR), and the Ionising Radiation Metrology Laboratory (LMRI) of the Centro de Investigaciones Energeticas, Medioambientales y Tecnologicas (CIEMAT) of Spain. The aim of the comparison was to establish the comparability of the measurement instruments and methods used to obtain radioactive reference materials of some gamma-emitting nuclides at CENTIS-DMR. The results revealed that there are no statistically significant differences between the data reported by both laboratories. (Author) 7 refs

  11. Digital auscultation of the uterine artery: a measure of uteroplacental perfusion.

    Science.gov (United States)

    Riknagel, Diana; Dinesen, Birthe; Zimmermann, Henrik; Farlie, Richard; Schmidt, Samuel; Toft, Egon; Struijk, Johannes Jan

    2016-07-01

    This observational study investigated digital auscultation for the purpose of assessing the clinical feasibility of monitoring vascular sounds in pregnancy. The study was performed at the Regional Hospital Viborg, Denmark, and included 29 pregnant women, 10 non-pregnant women and 10 male participants. Digital auscultation was performed with an electronic stethoscope bilaterally near the uterine arteries and correlated to the clinical diagnosis of preeclampsia (PE), intrauterine growth restriction (IUGR) or normal pregnancy in the group of pregnant participants. In the group of non-pregnant participants, digital auscultation was performed as control measurements in the same anatomical positions. The auscultations displayed pulse waveforms comprising systolic and diastolic periods in 20 of the 29 pregnant participants. However, in the non-pregnant and male participants, the pulse waveforms were absent. The pulsatile patterns are thus likely to originate from the arteries in relation to the pregnant uterus. In the participants displaying pulse waveforms, the presence of a dicrotic notch appeared with a sensitivity of 89% and a specificity of 100% in the discrimination of normal pregnancies (n  =  11) from pregnancies with PE or IUGR (n  =  9), (p  <  0.001). This preliminary study shows the potential of identifying vascular complications during pregnancy such as preeclampsia and intrauterine growth restriction. The morphology of the derived pulse contour should be investigated and could be further developed to identify pathophysiology.

  12. Bilateral mesial temporal sclerosis: MRI with high-resolution fast spin-echo and fluid-attenuated inversion-recovery sequences

    Energy Technology Data Exchange (ETDEWEB)

    Oppenheim, C.; Dormont, D.; Lehericy, S.; Marsault, C. [Dept. of Neuroradiology, Groupe Hospitalier Pite-Salpetriere, Paris (France); Hasboun, D. [Dept. of Neuroradiology, Groupe Hospitalier Pite-Salpetriere, Paris (France)]|[Dept. of Neurology, Paris VI Univ. (France); Bazin, B.; Samson, S.; Baulac, M. [Dept. of Neurology, Paris VI Univ. (France)

    1999-07-01

    We report a retrospective analysis of MRI in 206 patients with intractable seizures and describe the findings in bilateral mesial temporal sclerosis (MTS) on fast spin-echo (FSE) and fast fluid-attenuated inversion-recovery (fFLAIR) sequences. Criteria for MTS were atrophy, signal change and loss of the digitations of the head of the hippocampus. In patients with bilateral MRI signs of MTS, correlation with clinical electro, volumetric MRI data and neuropsychological tests, when available, was performed. Bilateral MTS was observed in seven patients. Bilateral loss of the digitations and signal change of fFLAIR was seen in all seven. In three, bilateral atrophy was obvious. In two patients, mild bilateral atrophy was observed and in two others, the hippocampi were: asymmetrical, with obvious atrophy on only one side. Volumetric data confirmed bilateral symmetrical atrophy in five patients, and volumes were at the lowest of the normal range in other two. The EEG showed temporal abnormalities in all patients, unilateral in five and bilateral in two. All patients had memory impairment and neuropsychological data confirmed visual and verbal memory deficits; two patients failed the Wada test on both sides. High-resolution T2-weighted FSE and fFLAIR sequences allow diagnosis of bilateral MTS, which has important therapeutic and prognostic implications. (orig.)

  13. Bilateral mesial temporal sclerosis: MRI with high-resolution fast spin-echo and fluid-attenuated inversion-recovery sequences

    International Nuclear Information System (INIS)

    Oppenheim, C.; Dormont, D.; Lehericy, S.; Marsault, C.; Hasboun, D.; Bazin, B.; Samson, S.; Baulac, M.

    1999-01-01

    We report a retrospective analysis of MRI in 206 patients with intractable seizures and describe the findings in bilateral mesial temporal sclerosis (MTS) on fast spin-echo (FSE) and fast fluid-attenuated inversion-recovery (fFLAIR) sequences. Criteria for MTS were atrophy, signal change and loss of the digitations of the head of the hippocampus. In patients with bilateral MRI signs of MTS, correlation with clinical electro, volumetric MRI data and neuropsychological tests, when available, was performed. Bilateral MTS was observed in seven patients. Bilateral loss of the digitations and signal change of fFLAIR was seen in all seven. In three, bilateral atrophy was obvious. In two patients, mild bilateral atrophy was observed and in two others, the hippocampi were: asymmetrical, with obvious atrophy on only one side. Volumetric data confirmed bilateral symmetrical atrophy in five patients, and volumes were at the lowest of the normal range in other two. The EEG showed temporal abnormalities in all patients, unilateral in five and bilateral in two. All patients had memory impairment and neuropsychological data confirmed visual and verbal memory deficits; two patients failed the Wada test on both sides. High-resolution T2-weighted FSE and fFLAIR sequences allow diagnosis of bilateral MTS, which has important therapeutic and prognostic implications. (orig.)

  14. Bilateral bone conduction devices: improved hearing ability in children with bilateral conductive hearing loss.

    Science.gov (United States)

    Dun, Catharina A J; Agterberg, Martijn J H; Cremers, Cor W R J; Hol, Myrthe K S; Snik, Ad F M

    2013-01-01

    The aim of the study was to investigate whether children with bilateral conductive hearing loss benefit from their second device (i.e., the bilateral bone conduction device [BCD]). Speech recognition in noise was assessed in 10 children fitted with bilateral BCDs during childhood. Speech recognition was measured in 2 conditions with both BCDs active. Spatial resolution was tested with the Minimum Audible Angle test in the bilateral and monaural listening conditions. Children demonstrated an improvement in speech recognition when speech was presented from the front and noise was presented from the right-hand side as compared with both speech and noise being presented from the front. The minimum audible angle decreased from 57° in the best monaural condition to 13° in the bilateral condition. The audiological outcomes demonstrate the advantage of bilateral BCD fitting in children with bilateral conductive hearing loss.

  15. A novel bilateral lower extremity mirror therapy intervention for individuals with stroke

    Directory of Open Access Journals (Sweden)

    Lucas D. Crosby

    2016-12-01

    Full Text Available Despite improvements made in stroke rehabilitation, motor impairment and gait deficits persist at discharge. New interventions are needed. Mirror therapy has promise as one element of a rehabilitation program. The primary objectives were to 1 describe a bilateral, lower extremity mirror therapy (LE-MT device and training protocol and 2 investigate the feasibility of LE-MT. A LE-MT device was constructed to train bilateral LE movements for 30 min, 3 times/week for 4 weeks, as an adjunct to physiotherapy in three individuals post-stroke. Sessions were digitally recorded and reviewed to extract feasibility measures; repetitions, rests and session duration. Pre and post measures of gait and motor impairment were taken. Two participants completed 100% of the sessions and a third completed 83% due to a recurrence of pre-existing back pain. Repetitions increased and session duration was maintained. Number of rests decreased for two participants and increased for one participant. Participants reported fatigue and mild muscle soreness but also that the intervention was tolerable. Positive gait changes included increased velocity and decreased variability. LE motor impairment also improved. A bilateral LE-MT adjunct intervention for stroke is feasible and may have positive effects. A history of low back pain should be a precaution.

  16. Comparison of unilateral and simultaneous bilateral measurement of the globe position, using the Hertel exophthalmometer.

    LENUS (Irish Health Repository)

    Ameri, Hossein

    2012-02-03

    PURPOSE: To assess the effect of simultaneous measurement of the two eyes in Hertel exophthalmometry (i.e., when both readings are taken sequentially, without removing the instrument from the orbital rims) and to find out whether simultaneous measurement would influence the final reading of each eye. METHODS: In this prospective, comparative study, Hertel exophthalmometry was performed on 61 patients by two experienced observers. Only patients with no history of orbital disease were included. Three different measurements were performed on each patient by each observer. Initially, the right eye was measured separately, then the left eye was measured separately, and finally, both eyes were measured together. RESULTS: When the eyes were measured separately, in 30% of cases observers obtained equal readings in both eyes; in 47%, the difference between the two eyes was 1 mm; and in 23%, the difference was 2 mm or more. However, in simultaneous bilateral measurements, in 73% of cases, observers obtained equal readings in both eyes; in 24%, the difference between the two eyes was 1 mm; and only in 3% was the difference 2 mm or greater. Paired t tests showed that the mean difference between measurements of the two eyes was significantly smaller in simultaneous bilateral measurements (p <0.001). Interobserver variation was similar for measurements taken separately on each eye and for simultaneous bilateral measurements. CONCLUSIONS: When both eyes were measured simultaneously with the Hertel exophthalmometer, examiners were inclined to obtain similar readings in both eyes of patients with symmetrical-appearing eyes. The possible bias arising this way may reduce the reliability of Hertel exophthalmometer in relative exophthalmometry.

  17. Experimental research of digital holographic microscopic measuring

    Science.gov (United States)

    Zhu, Xueliang; Chen, Feifei; Li, Jicheng

    2013-06-01

    Digital holography is a new imaging technique, which is developed on the base of optical holography, Digital processing, and Computer techniques. It is using CCD instead of the conventional silver to record hologram, and then reproducing the 3D contour of the object by the way of computer simulation. Compared with the traditional optical holographic, the whole process is of simple measuring, lower production cost, faster the imaging speed, and with the advantages of non-contact real-time measurement. At present, it can be used in the fields of the morphology detection of tiny objects, micro deformation analysis, and biological cells shape measurement. It is one of the research hot spot at home and abroad. This paper introduced the basic principles and relevant theories about the optical holography and Digital holography, and researched the basic questions which influence the reproduce images in the process of recording and reconstructing of the digital holographic microcopy. In order to get a clear digital hologram, by analyzing the optical system structure, we discussed the recording distance and of the hologram. On the base of the theoretical studies, we established a measurement and analyzed the experimental conditions, then adjusted them to the system. To achieve a precise measurement of tiny object in three-dimension, we measured MEMS micro device for example, and obtained the reproduction three-dimensional contour, realized the three dimensional profile measurement of tiny object. According to the experiment results consider: analysis the reference factors between the zero-order term and a pair of twin-images by the choice of the object light and the reference light and the distance of the recording and reconstructing and the characteristics of reconstruction light on the measurement, the measurement errors were analyzed. The research result shows that the device owns certain reliability.

  18. Relationship between selected measures of strength and hip and knee excursion during unilateral and bilateral landings in women.

    Science.gov (United States)

    McCurdy, Kevin; Walker, John; Armstrong, Rusty; Langford, George

    2014-09-01

    The purpose of this study was to compare the relationship between several measures of single-joint, isometric, eccentric, and squat strength and unilateral and bilateral landing mechanics at the hip and knee in women. Twenty six healthy female subjects with previous athletic experience (height, 165.1 ± 7.01 cm; mass, 60.91 ± 7.14 kg; age, 20.9 ± 1.62 years) participated in this study. Hip and knee mechanics were measured using the MotionMonitor capture system (Innovative Sports Training, Inc.) with 3-dimensional electromagnetic sensors during bilateral (60 cm) and unilateral drop jumps (30 cm). On a separate day, isometric hip extension, external rotation, and abduction strength (lbs) were measured using a handheld dynamometer (Hoggan Health Industries, Inc.). Eccentric and isometric knee strength were measured on the Biodex IV Isokinetic Dynamometer (Biodex Medical Systems, Inc.). Free weight was used to measure the bilateral squat and a modified single-leg squat. The strongest correlations were found between squat strength and knee valgus (-0.77 ≤ r ≤ -0.83) and hip adduction (-0.5 ≤ r ≤ -0.65). After controlling for squat strength, hip external rotation strength and unilateral knee valgus (-0.41), hip abduction strength and bilateral knee valgus (-0.43), and knee flexion strength and bilateral hip adduction (-0.57) remained significant. Eccentric knee flexion strength and unilateral knee internal rotation was the only significant correlation for eccentric strength (-0.40). Squat strength seems to be the best predictor of knee valgus and was consistently related to hip adduction. Isometric and eccentric measures demonstrated few significant correlations with hip and knee excursion while demonstrating a low-to-moderate relationship. Hip and knee flexion and rotation do not seem to be related to strength. Squat strength should receive consideration during risk assessment for noncontact knee injury.

  19. Influence of Signal Stationarity on Digital Stochastic Measurement Implementation

    Directory of Open Access Journals (Sweden)

    Ivan Župunski

    2013-06-01

    Full Text Available The paper presents the influence of signal stationarity on digital stochastic measurement method implementation. The implementation method is based on stochastic voltage generators, analog adders, low resolution A/D converter, and multipliers and accumulators implemented by Field-Programmable Gate Array (FPGA. The characteristic of first implementations of digital stochastic measurement was the measurement of stationary signal harmonics over the constant measurement period. Later, digital stochastic measurement was extended and used also when it was necessary to measure timeseries of non-stationary signal over the variable measurement time. The result of measurement is the set of harmonics, which is, in the case of non-stationary signals, the input for calculating digital values of signal in time domain. A theoretical approach to determine measurement uncertainty is presented and the accuracy trends with varying signal-to-noise ratio (SNR are analyzed. Noisy brain potentials (spontaneous and nonspontaneous are selected as an example of real non-stationary signal and its digital stochastic measurement is tested by simulations and experiments. Tests were performed without noise and with adding noise with SNR values of 10dB, 0dB and - 10dB. The results of simulations and experiments are compared versus theory calculations, and comparasion confirms the theory.

  20. Inter-arch digital model vs. manual cast measurements: Accuracy and reliability.

    Science.gov (United States)

    Kiviahde, Heikki; Bukovac, Lea; Jussila, Päivi; Pesonen, Paula; Sipilä, Kirsi; Raustia, Aune; Pirttiniemi, Pertti

    2017-06-28

    The purpose of this study was to evaluate the accuracy and reliability of inter-arch measurements using digital dental models and conventional dental casts. Thirty sets of dental casts with permanent dentition were examined. Manual measurements were done with a digital caliper directly on the dental casts, and digital measurements were made on 3D models by two independent examiners. Intra-class correlation coefficients (ICC), a paired sample t-test or Wilcoxon signed-rank test, and Bland-Altman plots were used to evaluate intra- and inter-examiner error and to determine the accuracy and reliability of the measurements. The ICC values were generally good for manual and excellent for digital measurements. The Bland-Altman plots of all the measurements showed good agreement between the manual and digital methods and excellent inter-examiner agreement using the digital method. Inter-arch occlusal measurements on digital models are accurate and reliable and are superior to manual measurements.

  1. Measurements of the Characteristics of Transparent Material Using Digital Holography

    Directory of Open Access Journals (Sweden)

    Ding Yu

    2013-01-01

    Full Text Available Digital holography is applied to measure the characteristics of transparent material. A digital hologram recording system to measure the surface of transparent material was established, and the digital holograms of transparent object were obtained in high quality. For postprocessing of hologram, the least-squares phase unwrapping algorithm was used in phase unwrapping, and the phase reconstruction image of transparent object was obtained. The information of material surfaces was measured and the characteristic was presented in 3D visualization. The validation experiment was conducted by NanoMap 500LS system; the results of validation experiment are well satisfied with the measurement by digital holography, which proved the feasibility of digital holographic technology as a good measurement tool for transparent material.

  2. Bilateral Comparison CIEMAT-CENTIS-DMR for radionuclide activity measurements; Comparacion Bilateral CIEMAT-CENTIS-DMR de la Medida de Actividad de Radionucleidos

    Energy Technology Data Exchange (ETDEWEB)

    Oropesa Verdecia, P.; Garcia-Torano, E.

    2004-07-01

    We present the results of a bilateral comparison of radionuclide activity measurements between the Radionuclide Metrology Department of the Center of Isotopes of Cuba (CENTIS-DMR), and the Ionising Radiation Metrology Laboratory (LMRI) of the Centro de Investigaciones Energeticas, Medioambientales y Tecnologicas (CIEMAT) of Spain. The aim of the comparison was to establish the comparability of the measurement instruments and methods used to obtain radioactive reference materials of some gamma-emitting nuclides at CENTIS-DMR. The results revealed that there are no statistically significant differences between the data reported by both laboratories. (Author) 7 refs.

  3. Micro-Structure Measurement and Imaging Based on Digital Holography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kyeong Suk; Jung, Hyun Chul; Chang, Ho Seob; Akhter, Naseem [Chosun University, Gwangju (Korea, Republic of); Kee, Chang Doo [Chonnam National University, Gwangju (Korea, Republic of)

    2010-06-15

    Advancements in the imaging and computing technology have opened the path to digital holography for non-destructive investigations of technical samples, material property measurement, vibration analysis, flow visualization and stress analysis in aerospace industry which has widened the application of digital holography in the above fields. In this paper, we demonstrate the non-destructive investigation and micro-structure measurement application of digital holography to the small particles and a biological sample. This paper gives a brief description of the digital holograms recorded with this system and illustratively demonstrated

  4. Micro-Structure Measurement and Imaging Based on Digital Holography

    International Nuclear Information System (INIS)

    Kim, Kyeong Suk; Jung, Hyun Chul; Chang, Ho Seob; Akhter, Naseem; Kee, Chang Doo

    2010-01-01

    Advancements in the imaging and computing technology have opened the path to digital holography for non-destructive investigations of technical samples, material property measurement, vibration analysis, flow visualization and stress analysis in aerospace industry which has widened the application of digital holography in the above fields. In this paper, we demonstrate the non-destructive investigation and micro-structure measurement application of digital holography to the small particles and a biological sample. This paper gives a brief description of the digital holograms recorded with this system and illustratively demonstrated

  5. Measuring Digital Signage ROI : A combination of Digital Signage and Mobile Advertising as a method for measuring Digtal Signage ROI

    OpenAIRE

    Helander, Fredrik

    2010-01-01

    Marketing has changed a lot the past decade. New modern marketing channels have been developed and marketing have become more effective. This has affected the expectations advertisers have on advertising channels. One thing advertisers increasingly expect is to be able to efficiently measure the result of advertising, the ROI. A method for measuring ROI of digital signage is in focus in this study. The measurement is enabled by a combination of digital signage and mobile advertising. First a ...

  6. Measurement methods to build up the digital optical twin

    Science.gov (United States)

    Prochnau, Marcel; Holzbrink, Michael; Wang, Wenxin; Holters, Martin; Stollenwerk, Jochen; Loosen, Peter

    2018-02-01

    The realization of the Digital Optical Twin (DOT), which is in short the digital representation of the physical state of an optical system, is particularly useful in the context of an automated assembly process of optical systems. During the assembly process, the physical system status of the optical system is continuously measured and compared with the digital model. In case of deviations between physical state and the digital model, the latter one is adapted to match the physical state. To reach the goal described above, in a first step measurement/characterization technologies concerning their suitability to generate a precise digital twin of an existing optical system have to be identified and evaluated. This paper gives an overview of possible characterization methods and, finally, shows first results of evaluated, compared methods (e.g. spot-radius, MTF, Zernike-polynomials), to create a DOT. The focus initially lies on the unequivocalness of the optimization results as well as on the computational time required for the optimization to reach the characterized system state. Possible sources of error are the measurement accuracy (to characterize the system) , execution time of the measurement, time needed to map the digital to the physical world (optimization step) as well as interface possibilities to integrate the measurement tool into an assembly cell. Moreover, it is to be discussed whether the used measurement methods are suitable for a `seamless' integration into an assembly cell.

  7. Measuring Claw Conformation in Cattle: Assessing the Agreement between Manual and Digital Measurement

    Directory of Open Access Journals (Sweden)

    Linda J. Laven

    2015-08-01

    Full Text Available Five measurements of claw conformation (toe angle, claw height, claw width, toe length and abaxial groove length taken directly from the hoof were compared with the measurements taken from digital images of the same claws. Concordance correlation coefficients and limits-of-agreement analysis showed that, for four of the five measures (claw height, claw width, toe length and abaxial groove length, agreement was too poor for digital and manual measures to be used interchangeably. For all four of these measures, Liao’s modified concordance correlation coefficient (mCCC was ≤0.4, indicating poor concordance despite Pearson’s correlation being >0.6 in all cases. The worst concordance was seen for toe length (mCCC = 0.13. Limits-of-agreement analysis showed that, for all four measures, there was a large variation in the difference between the manual and digital methods, even when the effect of mean on difference was accounted for, with the 95% limits-of-agreement for the four measures being further away from the mean difference than 10% of the mean in all four cases. The only one of the five measures with an acceptable concordance between digital and manual measurement was toe angle (mCCC = 0.81. Nevertheless, the limits-of-agreement analysis showed that there was a systematic bias with, on average, the manual measure of toe angle, being 2.1° smaller than the digital. The 95% limits-of-agreement for toe angle were ±3.4°, probably at the upper limit of what is acceptable. However, the lack of data on the variability of individual measurements of claw conformation means that it is unclear how this variability compares to measurement of toe angle in the same animal using the same or a different manual technique.

  8. Evaluation of the intercanine distance in newborns with cleft lip and palate using 3D digital casts

    Directory of Open Access Journals (Sweden)

    Bianca Zeponi Fernandes Mello

    2013-09-01

    Full Text Available OBJECTIVE: The purpose of this present study was to compare, by means of 3D digital casts, the anterior transverse dimension of the dental arch of newborns with and without cleft lip and palate. MATERIAL AND METHODS: The sample was composed of ninety-four children aged from 3 to 9 months divided into three study groups: Group I - children without craniofacial deformities (control group; Group II - children with unilateral cleft lip and palate; Group III - children with bilateral cleft lip and palate. Impressions were executed before lip and palate repair in patients with clefts. Dental casts were digitized using a 3D scanner linked to a computer. Measurements of the intercanine distance were measured on the digital casts. Intergroup comparisons were performed using ANOVA (p<0.05. RESULTS: The results showed a mean of 36.5 mm for unilateral cleft lip and palate group, 34.8 mm for bilateral cleft lip and palate group and 27.52 mm for the control group. There was a statistically significant difference between the control group and both groups of patients with cleft lip and palate. There was no statistically significant difference between complete unilateral and bilateral cleft lip and palate groups. CONCLUSIONS: Patients with complete cleft lip and palate were born with an increased anterior dimension of the maxillary dental arch compared to non cleft patients.

  9. Evaluation of the intercanine distance in newborns with cleft lip and palate using 3D digital casts

    Science.gov (United States)

    MELLO, Bianca Zeponi Fernandes; FERNANDES, Viviane Mendes; CARRARA, Cleide Felício Carvalho; MACHADO, Maria Aparecida Andrade Moreira; GARIB, Daniela Gamba; OLIVEIRA, Thais Marchini

    2013-01-01

    Objective The purpose of this present study was to compare, by means of 3D digital casts, the anterior transverse dimension of the dental arch of newborns with and without cleft lip and palate. Material and Methods The sample was composed of ninety-four children aged from 3 to 9 months divided into three study groups: Group I - children without craniofacial deformities (control group); Group II - children with unilateral cleft lip and palate; Group III - children with bilateral cleft lip and palate. Impressions were executed before lip and palate repair in patients with clefts. Dental casts were digitized using a 3D scanner linked to a computer. Measurements of the intercanine distance were measured on the digital casts. Intergroup comparisons were performed using ANOVA (p<0.05). Results The results showed a mean of 36.5 mm for unilateral cleft lip and palate group, 34.8 mm for bilateral cleft lip and palate group and 27.52 mm for the control group. There was a statistically significant difference between the control group and both groups of patients with cleft lip and palate. There was no statistically significant difference between complete unilateral and bilateral cleft lip and palate groups. Conclusions Patients with complete cleft lip and palate were born with an increased anterior dimension of the maxillary dental arch compared to non cleft patients. PMID:24212990

  10. Dynamic positron emission tomography image restoration via a kinetics-induced bilateral filter.

    Directory of Open Access Journals (Sweden)

    Zhaoying Bian

    Full Text Available Dynamic positron emission tomography (PET imaging is a powerful tool that provides useful quantitative information on physiological and biochemical processes. However, low signal-to-noise ratio in short dynamic frames makes accurate kinetic parameter estimation from noisy voxel-wise time activity curves (TAC a challenging task. To address this problem, several spatial filters have been investigated to reduce the noise of each frame with noticeable gains. These filters include the Gaussian filter, bilateral filter, and wavelet-based filter. These filters usually consider only the local properties of each frame without exploring potential kinetic information from entire frames. Thus, in this work, to improve PET parametric imaging accuracy, we present a kinetics-induced bilateral filter (KIBF to reduce the noise of dynamic image frames by incorporating the similarity between the voxel-wise TACs using the framework of bilateral filter. The aim of the proposed KIBF algorithm is to reduce the noise in homogeneous areas while preserving the distinct kinetics of regions of interest. Experimental results on digital brain phantom and in vivo rat study with typical (18F-FDG kinetics have shown that the present KIBF algorithm can achieve notable gains over other existing algorithms in terms of quantitative accuracy measures and visual inspection.

  11. Digital Lengthening to Treat Finger Deficiency: An Experience of 201 Digits in 104 Patients

    OpenAIRE

    Ding, Zhenyu; Zhu, Xiaozhong; Fu, Kai; Zheng, Xianyou

    2017-01-01

    Objectives. We evaluated the results of digital lengthening by distraction and second-stage bone graft. Methods. We treated finger deficiency of 201 digits in 104 patients (68 males, 36 females) by digital distraction and second-stage bone graft. The distraction was performed with a rate of 1 mm/day (for the first ten days) and 0.5 mm/day followed by using a self-designed bilateral tubal-helical external fixator. The mean follow-up period was 42 months (range 6 to 60 months). Results. The mea...

  12. Parameters-adjustable front-end controller in digital nuclear measurement system

    International Nuclear Information System (INIS)

    Hao Dejian; Zhang Ruanyu; Yan Yangyang; Wang Peng; Tang Changjian

    2013-01-01

    Background: One digitizer is used to implement a digital nuclear measurement for the acquisition of nuclear information. Purpose: A principle and method of a parameter-adjustable front-end controller is presented for the sake of reducing the quantitative errors while getting the maximum ENOB (effective number of bits) of ADC (analog-to-digital converter) during waveform digitizing, as well as reducing the losing counts. Methods: First of all, the quantitative relationship among the radiation count rate (n), the amplitude of input signal (V in ), the conversion scale of ADC (±V) and the amplification factor (A) was derived. Secondly, the hardware and software of the front-end controller were designed to fulfill matching the output of different detectors, adjusting the amplification linearly through the control of channel switching, and setting of digital potentiometer by CPLD (Complex Programmable Logic Device). Results: (1) Through the measurement of γ-ray of Am-241 under our digital nuclear measurement set-up with CZT detector, it was validated that the amplitude of output signal of detectors of RC feedback type could be amplified linearly with adjustable amplification by the front-end controller. (2) Through the measurement of X-ray spectrum of Fe-5.5 under our digital nuclear measurement set-up with Si-PIN detector, it was validated that the front-end controller was suitable for the switch resetting type detectors, by which high precision measurement under various count rates could be fulfilled. Conclusion: The principle and method of the parameter-adjustable front-end controller presented in this paper is correct and feasible. (authors)

  13. Field-Deployable Acoustic Digital Systems for Noise Measurement

    Science.gov (United States)

    Shams, Qamar A.; Wright, Kenneth D.; Lunsford, Charles B.; Smith, Charlie D.

    2000-01-01

    Langley Research Center (LaRC) has for years been a leader in field acoustic array measurement technique. Two field-deployable digital measurement systems have been developed to support acoustic research programs at LaRC. For several years, LaRC has used the Digital Acoustic Measurement System (DAMS) for measuring the acoustic noise levels from rotorcraft and tiltrotor aircraft. Recently, a second system called Remote Acquisition and Storage System (RASS) was developed and deployed for the first time in the field along with DAMS system for the Community Noise Flight Test using the NASA LaRC-757 aircraft during April, 2000. The test was performed at Airborne Airport in Wilmington, OH to validate predicted noise reduction benefits from alternative operational procedures. The test matrix was composed of various combinations of altitude, cutback power, and aircraft weight. The DAMS digitizes the acoustic inputs at the microphone site and can be located up to 2000 feet from the van which houses the acquisition, storage and analysis equipment. Digitized data from up to 10 microphones is recorded on a Jaz disk and is analyzed post-test by microcomputer system. The RASS digitizes and stores acoustic inputs at the microphone site that can be located up to three miles from the base station and can compose a 3 mile by 3 mile array of microphones. 16-bit digitized data from the microphones is stored on removable Jaz disk and is transferred through a high speed array to a very large high speed permanent storage device. Up to 30 microphones can be utilized in the array. System control and monitoring is accomplished via Radio Frequency (RF) link. This paper will present a detailed description of both systems, along with acoustic data analysis from both systems.

  14. Digital Divide Measurement in Lembata Regency Using SIBIS

    Science.gov (United States)

    Gabriel, Cecilia Dai Payon Binti; Setyohadi, Djoko Budiyanto; Suyoto

    2018-02-01

    Along with technological development in Indonesia, digital divide occurs in various regions, which were behind in terms of information on how to use, access and utilize ICT in collecting information from internet. One of the regions is Lembata Regency in East Nusa Tenggara, where digital divide among the people should be measured. The purpose of this study was to determine the level of digital divide among the people of Lembata Regency. To determine the level of digital divide, we used SIBIS GPS (General Population Survey) method, which consisted of several indicators or aspect, i.e. internet usage behavior, internet utilization, and e-government. We also performed two tests, i.e. validity test and reliability test to obtain value of index of digital divide measurement among the people of Lembata Regency. The results of validity test which is processed using SPSS program are categorized valid for each variable indicator and the reliability test results show reliable status. According to the test results on digital discrepancy in Lembata people, the internet usage attitude indicator is categorized low which is 63.1%, the internet usage function indicator is categorized low which is 64%, and the digital discrepancy of e-government indicator is categorized medium which is 40.4%. Therefore, the result of this study because consideration for the government of Lembata Regency in improving ICT services in e-government and in distributing ICT access and ability equally to the people.

  15. Digital module for neutron flux measurement by Campbell method

    International Nuclear Information System (INIS)

    Baratte, G.

    1987-02-01

    The study reported here concerns a wide range measurement channel for reactor control instrumentation but it may also be useful for specific measurements requiring the Campbell method. A wide range measurement channel allows the processing of the signal issued from a single fission chamber so it's possible to insure control of nuclear reactors in three different running modes: pulse processing, fluctuations and current. The study described in this note includes three parts: - the analogical wide range neutron measurement channel is presented in the first chapter; the fluctuation mode is thoroughly studied; the results of tests and proper limitations of analogical processing are summarized. A theoretical study of the neutron flux measurement by numerical calculation of the fluctuation signal variance is given in the second chapter. The digital module is described in the third chapter; the results of experiments are analysed. The validity of the digital method is proved by means of a practical realisation. The performances obtained with the digital fluctuation test model may be compared with those given by the analogical fluctuation channel which can be used for the control of lower fission rates. The digital module may also be used for any fluctuation measurement where very short response time and broad spectral band of analysis are not strictly necessary [fr

  16. Correlation and agreement of a digital and conventional method to measure arch parameters.

    Science.gov (United States)

    Nawi, Nes; Mohamed, Alizae Marny; Marizan Nor, Murshida; Ashar, Nor Atika

    2018-01-01

    The aim of the present study was to determine the overall reliability and validity of arch parameters measured digitally compared to conventional measurement. A sample of 111 plaster study models of Down syndrome (DS) patients were digitized using a blue light three-dimensional (3D) scanner. Digital and manual measurements of defined parameters were performed using Geomagic analysis software (Geomagic Studio 2014 software, 3D Systems, Rock Hill, SC, USA) on digital models and with a digital calliper (Tuten, Germany) on plaster study models. Both measurements were repeated twice to validate the intraexaminer reliability based on intraclass correlation coefficients (ICCs) using the independent t test and Pearson's correlation, respectively. The Bland-Altman method of analysis was used to evaluate the agreement of the measurement between the digital and plaster models. No statistically significant differences (p > 0.05) were found between the manual and digital methods when measuring the arch width, arch length, and space analysis. In addition, all parameters showed a significant correlation coefficient (r ≥ 0.972; p digital and manual measurements. Furthermore, a positive agreement between digital and manual measurements of the arch width (90-96%), arch length and space analysis (95-99%) were also distinguished using the Bland-Altman method. These results demonstrate that 3D blue light scanning and measurement software are able to precisely produce 3D digital model and measure arch width, arch length, and space analysis. The 3D digital model is valid to be used in various clinical applications.

  17. Vibration measurements by pulsed digital holographic endoscopy

    Science.gov (United States)

    Schedin, Staffan; Pedrini, Giancarlo; Perez-Lopez, Carlos; Mendoza Santoyo, Fernando

    2005-02-01

    Digital holographic interferometry in combination with a flexible fiber endoscope allows high precision measurements of deformations on hidden objects surfaces, inside cavities and objects with small access apertures. A digital holographic endoscopy system is described with a frequency-doubled, twin oscillator Q-switched pulsed Nd:YAG laser as light source. A sequence of digital hologram pairs are recorded with a maximum repetition rate of 260 ms. Each digital hologram is captured at separate video frames of a CCD-camera. The time separation between the laser pulses from each cavity can be set in the range from 50 to 500 μs. The digital holograms are transferred to a PC via a frame grabber and evaluated quantitatively by the Fourier transform method. The resulting phase fringe pattern has the information needed to evaluate quantitatively the amount of the deformation. Experimental results of vibration measurements of hidden mechanical and biological object surfaces are presented. The quality of the results obtained by mechanical object surfaces is usually higher than for biological surfaces. This can be explained easily by the fact that a biological surface is much more complex than a mechanical surface in the sense that some parts of the surface may reflect the light well whereas other parts may absorb the light. Also, biological surfaces are translucent, which means that part of the light may enter inside the sample where it may be absorbed or reflected.

  18. Bilateral electric energy contracts: return and risk

    Energy Technology Data Exchange (ETDEWEB)

    Gunn, Laura K.; Silva, Elisa B.; Correia, Paulo B. [State University of Campinas (UNICAMP), SP (Brazil). College of Mechanical Engineering

    2009-07-01

    In Brazil electricity is traded through three segments: the spot market that balances offer and demand, with prices calculated by a cost-based computational model; the regulated market , where prices are settled in public auctions, and the free market for bilateral contracts. As spot and regulated market prices are public information, a seller is able to calculate his opportunity price to trade a bilateral contract in the free market by using the non-arbitrage principle. Thus, the seller searches the price of a bilateral contract in the free market that balances his/her revenues with the value expected in case it were negotiated in the regulated and the spot market. Besides the expected revenue, the seller may also consider the CVaR to measure the risk of her/his bilateral contract in the free market. So this paper develops a binomial lattice approach to price bilateral contracts in the free market, considering the seller's opportunity of negotiations in both regulated and spot markets, and measuring the contract risk directly. (author)

  19. Bilateral breast carcinoma: results with breast conservation therapy and a comparison with bilateral mastectomy

    International Nuclear Information System (INIS)

    Kim, David H.; Haffty, Bruce G.

    1996-01-01

    between the BCT, UCT, and BMAST groups with respect to age, histology, clinical stage, primary tumor size, axillary nodal status, or adjuvant systemic therapy. As noted below, there were no statistically significant differences between the three study groups with respect to overall survival, disease-free survival, distant metastasis-free survival, or local regional relapse-free survival. It is noteworthy that there was no significant difference between the local breast relapse rate and the chest wall relapse rate when comparing the conservatively treated group and the bilateral mastectomy group. Conclusions: Patients with bilateral breast carcinoma presenting either synchronously or metachronously are suitable candidates for bilateral conservative treatment. Outcome of these patients with respect to all measurable endpoints did not significantly differ from patients treated conservatively for unilateral breast cancer, or for their counterparts with bilateral disease of similar stage treated with bilateral mastectomy. Of particular note, the 10-year local regional relapse-free rate of patients undergoing bilateral mastectomy did not differ significantly from the local regional relapse rate of those patients treated with bilateral conservative treatment

  20. Bilateral cochlear implantation in a patient with bilateral temporal bone fractures.

    Science.gov (United States)

    Chung, Jae Ho; Shin, Myung Chul; Min, Hyun Jung; Park, Chul Won; Lee, Seung Hwan

    2011-01-01

    With the emphasis on bilateral hearing nowadays, bilateral cochlear implantation has been tried out for bilateral aural rehabilitation. Bilateral sensorineural hearing loss caused by head trauma can get help from cochlear implantation. We present the case of a 44-year-old man with bilateral otic capsule violating temporal bone fractures due to head trauma. The patient demonstrated much improved audiometric and psychoacoustic performance after bilateral cochlear implantation. We believe bilateral cochlear implantation in such patient can be a very effective tool for rehabilitation. Copyright © 2011 Elsevier Inc. All rights reserved.

  1. Measurement-device-independent quantum digital signatures

    Science.gov (United States)

    Puthoor, Ittoop Vergheese; Amiri, Ryan; Wallden, Petros; Curty, Marcos; Andersson, Erika

    2016-08-01

    Digital signatures play an important role in software distribution, modern communication, and financial transactions, where it is important to detect forgery and tampering. Signatures are a cryptographic technique for validating the authenticity and integrity of messages, software, or digital documents. The security of currently used classical schemes relies on computational assumptions. Quantum digital signatures (QDS), on the other hand, provide information-theoretic security based on the laws of quantum physics. Recent work on QDS Amiri et al., Phys. Rev. A 93, 032325 (2016);, 10.1103/PhysRevA.93.032325 Yin, Fu, and Zeng-Bing, Phys. Rev. A 93, 032316 (2016), 10.1103/PhysRevA.93.032316 shows that such schemes do not require trusted quantum channels and are unconditionally secure against general coherent attacks. However, in practical QDS, just as in quantum key distribution (QKD), the detectors can be subjected to side-channel attacks, which can make the actual implementations insecure. Motivated by the idea of measurement-device-independent quantum key distribution (MDI-QKD), we present a measurement-device-independent QDS (MDI-QDS) scheme, which is secure against all detector side-channel attacks. Based on the rapid development of practical MDI-QKD, our MDI-QDS protocol could also be experimentally implemented, since it requires a similar experimental setup.

  2. ADC border effect and suppression of quantization error in the digital dynamic measurement

    International Nuclear Information System (INIS)

    Bai Li-Na; Liu Hai-Dong; Zhou Wei; Zhai Hong-Qi; Cui Zhen-Jian; Zhao Ming-Ying; Gu Xiao-Qian; Liu Bei-Ling; Huang Li-Bei; Zhang Yong

    2017-01-01

    The digital measurement and processing is an important direction in the measurement and control field. The quantization error widely existing in the digital processing is always the decisive factor that restricts the development and applications of the digital technology. In this paper, we find that the stability of the digital quantization system is obviously better than the quantization resolution. The application of a border effect in the digital quantization can greatly improve the accuracy of digital processing. Its effective precision has nothing to do with the number of quantization bits, which is only related to the stability of the quantization system. The high precision measurement results obtained in the low level quantization system with high sampling rate have an important application value for the progress in the digital measurement and processing field. (paper)

  3. Computerized detection of mass lesions in digital mammograms

    International Nuclear Information System (INIS)

    Yin, F.F.; Giger, M.L.; Doi, K.; Metz, C.E.; Vyborny, C.J.; Schmidt, R.A.

    1989-01-01

    Early detection of breast cancer from the periodic screening of asymptomatic women could reduce breast cancer mortality by at least 40%. The authors are developing a computerized scheme for the detection of mass lesions in digital mammograms as an aid to radiologists in such high volume screening programs. Based on left-right architectural symmetry and gray-level histogram analysis, bilateral subtraction of left and right breast images is performed. False-positive detections included in bilateral-difference images are reduced with various images feature-extraction techniques. The database involves clinical film mammograms digitized by a TV camera and analyzed on a Micro-VAX workstation. Among five different bilateral subtraction techniques investigated, a nonlinear approach provided superior lesion enhancement. Feature-extraction techniques reduced substantially the remaining false-positives. Preliminary results, for 32 pairs of clinical mammograms, yielded a true-positive rate of approximately 95% with a false-positive rate of about 2 per image

  4. ASYMMETRY OF SOMATOSENSORY CORTICAL PLASTICITY IN PATIENT WITH BILATERAL CARPAL TUNNEL SYNDROME

    Directory of Open Access Journals (Sweden)

    Hikmat Hadoush

    2017-09-01

    Full Text Available Background: Following peripheral nerve lesion, the adult somatosensory system showedcortical reorganizational abilities.Previous studies identified the digits' somatotopy map changes and somatosensory cortical plasticity in response to the Carpal Tunnel Syndrome (CTS that affected the dominant hand only. Objective: Answering the remained question is that what the extent of the cortical plasticity would be in left and right somatosensory cortices in response to CTS affecting the right and left hands simultaneously. Methods: Cortical representations activated by tactile stimulation of median nerve (index and ulnar nerve (little of both dominant and non-dominant hands were evaluated by Magnetoencephalography (MEG systemfor healthy participants and patient with bilateral moderate CTS. index – little fingers'somatotopy map and inter-digit cortical distance was then mapped and calculated for each participant on the real MRI data and the 3D brain surface image. Results: in healthy participants, index – little inter-digit somatosensory cortical distance of right hand (dominant was significantly larger than the index – little inter-digitsomatosensory cortical distance of left hand (11.2±2.1mm vs.7.0±2.9mm, P = 0.006. However, in patient with bilateral CTS, the index – little inter-digit somatosensory cortical distance of righthand (dominant was significantly smaller than the index – little inter-digit somatosensory cortical distance of left hand (5.8mm vs. 7.4mm. Conclusion: our data could be interpreted as the hand use – dependency served more median nerve – cortical territory from the ulnar nerve invasion in the right somatotopy map (left hand than the left somatotopy map of the right hand.

  5. Bilateral comparison between PTB and ENEA to check the performance of a commercial TDCR system for activity measurements

    International Nuclear Information System (INIS)

    Kossert, Karsten; Capogni, Marco; Nähle, Ole J.

    2014-01-01

    The only commercial TDCR counter from Hidex Oy (Finland), comprising three photomultiplier tubes, was tested at the two National Metrology Institutes (NMIs) PTB and ENEA. To this end, the two NMIs purchased a Hidex 300 SL TDCR counter (METRO version) each and carried out various tests at their laboratories. In addition, the two institutions agreed to organize a bilateral comparison in order to acquire information on the reproducibility of the results obtained with the counters. To achieve this, PTB prepared some 89 Sr liquid scintillation samples, which were first measured in various counters at PTB and then shipped to ENEA for comparative measurements. The aim of this paper is to summarize the findings on the counter characteristics and adjustments. In addition, the results of the bilateral comparison between PTB and ENEA are presented and the results from various commercial counters using the CIEMAT/NIST efficiency tracing and the TDCR method are discussed. - Highlights: • The TDCR counter from Hidex Oy was tested at PTB and ENEA. • The studies comprised linearity checks and investigation of adjustments. • A bilateral 89 Sr comparison was organized to compare two Hidex counters

  6. Digital measurement system for the LHC klystron high voltage modulator.

    CERN Document Server

    Mikkelsen, Anders

    Accelerating voltage in the Large Hadron Collider (LHC) is created by a means of 16 superconducting standing wave RF cavities, each fed by a 400MHz/300kW continuous wave klystron amplifier. Part of the upgrade program for the LHC long shutdown one is to replace the obsolete analogue current and voltage measurement circuitry located in the high voltage bunkers by a new, digital system, using ADCs and optical fibres. A digital measurement card is implemented and integrated into the current HV modulator oil tank (floating at -58kV) and interfaced to the existing digital VME boards collecting the data for several klystrons at the ground potential. Measured signals are stored for the logging, diagnostics and post-mortem analysis purposes.

  7. Noise Reduction of Measurement Data using Linear Digital Filters

    Directory of Open Access Journals (Sweden)

    Hitzmann B.

    2007-12-01

    Full Text Available In this paper Butterworth, Chebyshev (Type I and II and Elliptic digital filters are designed for signal noise reduction. On-line data measurements of substrate concentration from E. coli fed-batch cultivation process are used. Application of the designed filters leads to a successful noise reduction of on-line glucose measurements. The digital filters presented here are simple, easy to implement and effective - the used filters allow for a smart compromise between signal information and noise corruption.

  8. Fully automated joint space width measurement and digital X-ray radiogrammetry in early RA.

    Science.gov (United States)

    Platten, Michael; Kisten, Yogan; Kälvesten, Johan; Arnaud, Laurent; Forslind, Kristina; van Vollenhoven, Ronald

    2017-01-01

    To study fully automated digital joint space width (JSW) and bone mineral density (BMD) in relation to a conventional radiographic scoring method in early rheumatoid arthritis (eRA). Radiographs scored by the modified Sharp van der Heijde score (SHS) in patients with eRA were acquired from the SWEdish FarmacOTherapy study. Fully automated JSW measurements of bilateral metacarpals 2, 3 and 4 were compared with the joint space narrowing (JSN) score in SHS. Multilevel mixed model statistics were applied to calculate the significance of the association between ΔJSW and ΔBMD over 1 year, and the JSW differences between damaged and undamaged joints as evaluated by the JSN. Based on 576 joints of 96 patients with eRA, a significant reduction from baseline to 1 year was observed in the JSW from 1.69 (±0.19) mm to 1.66 (±0.19) mm (p0) joints: 1.68 mm (95% CI 1.70 to 1.67) vs 1.54 mm (95% CI 1.63 to 1.46). Similarly the unadjusted multilevel model showed significant differences in JSW between undamaged (1.68 mm (95% CI 1.72 to 1.64)) and damaged joints (1.63 mm (95% CI 1.68 to 1.58)) (p=0.0048). This difference remained significant in the adjusted model: 1.66 mm (95% CI 1.70 to 1.61) vs 1.62 mm (95% CI 1.68 to 1.56) (p=0.042). To measure the JSW with this fully automated digital tool may be useful as a quick and observer-independent application for evaluating cartilage damage in eRA. NCT00764725.

  9. Comparison of conventional study model measurements and 3D digital study model measurements from laser scanned dental impressions

    Science.gov (United States)

    Nugrahani, F.; Jazaldi, F.; Noerhadi, N. A. I.

    2017-08-01

    The field of orthodontics is always evolving,and this includes the use of innovative technology. One type of orthodontic technology is the development of three-dimensional (3D) digital study models that replace conventional study models made by stone. This study aims to compare the mesio-distal teeth width, intercanine width, and intermolar width measurements between a 3D digital study model and a conventional study model. Twelve sets of upper arch dental impressions were taken from subjects with non-crowding teeth. The impressions were taken twice, once with alginate and once with polivinylsiloxane. The alginate impressions used in the conventional study model and the polivinylsiloxane impressions were scanned to obtain the 3D digital study model. Scanning was performed using a laser triangulation scanner device assembled by the School of Electrical Engineering and Informatics at the Institut Teknologi Bandung and David Laser Scan software. For the conventional model, themesio-distal width, intercanine width, and intermolar width were measured using digital calipers; in the 3D digital study model they were measured using software. There were no significant differences between the mesio-distal width, intercanine width, and intermolar width measurments between the conventional and 3D digital study models (p>0.05). Thus, measurements using 3D digital study models are as accurate as those obtained from conventional study models

  10. General temperature field measurement by digital holography

    Czech Academy of Sciences Publication Activity Database

    Doleček, Roman; Psota, Pavel; Lédl, Vít; Vít, Tomáš; Václavík, Jan; Kopecký, V.

    2013-01-01

    Roč. 52, č. 1 (2013), A319-A325 ISSN 1559-128X Institutional support: RVO:61389021 Keywords : digital holography * temperature field measurement * tomography Subject RIV: BH - Optics, Masers, Lasers Impact factor: 1.649, year: 2013

  11. Digital image technology and a measurement tool in physical models

    CSIR Research Space (South Africa)

    Phelp, David

    2006-05-01

    Full Text Available Advances in digital image technology has allowed us to use accurate, but relatively cost effective technology to measure a number of varied activities in physical models. The capturing and manipulation of high resolution digital images can be used...

  12. Accuracy of 3-dimensional curvilinear measurements on digital models with intraoral scanners.

    Science.gov (United States)

    Mack, Spencer; Bonilla, Tammy; English, Jeryl D; Cozad, Benjamin; Akyalcin, Sercan

    2017-09-01

    Our objectives were to evaluate and compare the digital dental models generated from 2 commercial intraoral scanners with manual measurements when performing 3-dimensional surface measurements along a curved line (curvilinear). Dry mandibles (n = 61) with intact dentition were used. The mandibles were digitized using 2 chair-side intraoral scanners: Cadent iTero (Align Technology, San Jose, Calif) and Lythos Digital Impression system (Ormco, Orange, Calif). Digitized 3-dimensional models were converted to individual stereolithography files and used with commercial software to obtain the curvilinear measurements. Manual measurements were carried out directly on the mandibular teeth. Measurements were made on different locations on the dental arch in various directions. One-sample t tests and linear regression analyses were performed. To further graphically examine the accuracy between the different methods, Bland-Altman plots were computed. The level of significance was set at P 0.05). Bland-Altman analysis showed no fixed bias of 1 approach vs the other, and random errors were detected in all comparisons. Although the mean biases of the digital models obtained by the iTero and Lythos scanners, when compared with direct caliper measurements, were low, the comparison of the 2 intraoral scanners yielded the lowest mean bias. No comparison displayed statistical significance for the t scores; this indicated the absence of proportional bias in these comparisons. The intraoral scanners tested in this study produced digital dental models that were comparatively accurate when performing direct surface measurements along a curved line in 3 dimensions. Copyright © 2017 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  13. A compact wideband precision impedance measurement system based on digital auto-balancing bridge

    International Nuclear Information System (INIS)

    Hu, Binxin; Wang, Jinyu; Song, Guangdong; Zhang, Faxiang

    2016-01-01

    The ac impedance spectroscopy measurements are predominantly taken by using impedance analyzers based on analog auto-balancing bridge. However, those bench-top analyzers are generally complicated, bulky and expensive, thus limiting their usage in industrial field applications. This paper presents the development of a compact wideband precision measurement system based on digital auto-balancing bridge. The methods of digital auto-balancing bridge and digital lock-in amplifier are analyzed theoretically. The overall design and several key sections including null detector, direct digital synthesizer-based sampling clock, and digital control unit are introduced in detail. The results show that the system achieves a basic measurement accuracy of 0.05% with a frequency range of 20 Hz–2 MHz. The advantages of versatile measurement capacity, fast measurement speed, small size and low cost make it quite suitable for industrial field applications. It is demonstrated that this system is practical and effective by applying in determining the impedance-temperature characteristic of a motor starter PTC thermistor. (paper)

  14. A Rare Entity: Bilateral First Rib Fractures Accompanying Bilateral Scapular Fractures

    OpenAIRE

    Gulbahar, Gultekin; Kaplan, Tevfik; Turker, Hasan Bozkurt; Gundogdu, Ahmet Gokhan; Han, Serdar

    2015-01-01

    First rib fractures are scarce due to their well-protected anatomic locations. Bilateral first rib fractures accompanying bilateral scapular fractures are very rare, although they may be together with scapular and clavicular fractures. According to our knowledge, no case of bilateral first rib fractures accompanying bilateral scapular fractures has been reported, so we herein discussed the diagnosis, treatment, and complications of bone fractures due to thoracic trauma in bias of this rare en...

  15. A Rare Entity: Bilateral First Rib Fractures Accompanying Bilateral Scapular Fractures.

    Science.gov (United States)

    Gulbahar, Gultekin; Kaplan, Tevfik; Turker, Hasan Bozkurt; Gundogdu, Ahmet Gokhan; Han, Serdar

    2015-01-01

    First rib fractures are scarce due to their well-protected anatomic locations. Bilateral first rib fractures accompanying bilateral scapular fractures are very rare, although they may be together with scapular and clavicular fractures. According to our knowledge, no case of bilateral first rib fractures accompanying bilateral scapular fractures has been reported, so we herein discussed the diagnosis, treatment, and complications of bone fractures due to thoracic trauma in bias of this rare entity.

  16. [Bilateral cochlear implants].

    Science.gov (United States)

    Müller, J

    2017-07-01

    Cochlear implants (CI) are standard for the hearing rehabilitation of severe to profound deafness. Nowadays, if bilaterally indicated, bilateral implantation is usually recommended (in accordance with German guidelines). Bilateral implantation enables better speech discrimination in quiet and in noise, and restores directional and spatial hearing. Children with bilateral CI are able to undergo hearing-based hearing and speech development. Within the scope of their individual possibilities, bilaterally implanted children develop faster than children with unilateral CI and attain, e.g., a larger vocabulary within a certain time interval. Only bilateral implantation allows "binaural hearing," with all the benefits that people with normal hearing profit from, namely: better speech discrimination in quiet and in noise, as well as directional and spatial hearing. Naturally, the developments take time. Binaural CI users benefit from the same effects as normal hearing persons: head shadow effect, squelch effect, and summation and redundancy effects. Sequential CI fitting is not necessarily disadvantageous-both simultaneously and sequentially fitted patients benefit in a similar way. For children, earliest possible fitting and shortest possible interval between the two surgeries seems to positively influence the outcome if bilateral CI are indicated.

  17. A Rare Entity: Bilateral First Rib Fractures Accompanying Bilateral Scapular Fractures

    Directory of Open Access Journals (Sweden)

    Gultekin Gulbahar

    2015-01-01

    Full Text Available First rib fractures are scarce due to their well-protected anatomic locations. Bilateral first rib fractures accompanying bilateral scapular fractures are very rare, although they may be together with scapular and clavicular fractures. According to our knowledge, no case of bilateral first rib fractures accompanying bilateral scapular fractures has been reported, so we herein discussed the diagnosis, treatment, and complications of bone fractures due to thoracic trauma in bias of this rare entity.

  18. Clinical study of cerebral blood flow in bilateral chronic subdural hematoma measured by 99mTc-HMPAO SPECT

    International Nuclear Information System (INIS)

    Okuyama, Tohru; Saito, Koji; Fukuyama, Kohichi; Yamamoto, Kouki; Morimoto, Mamoru; Aburano, Tamio

    2000-01-01

    Cerebral blood flow (CBF) in 34 patients with bilateral chronic subdural hematoma was measured by 99m Tc-HMPAO SPECT before operation. The regional CBF was measured in 26 regions of the 10 cortical regions, putamen, thalamus and cerebellar hemisphere on both sides. According to the thickness of subdural hematoma, the thicker hematoma side was measured and examined as the thick hematoma side, and the other side as the thin hematoma side. Thirty four cases with bilateral chronic subdural hematoma were classified into four groups on the basis of clinical symptoms :13 cases with headache (headache group), 10 cases with hemiparesis (hemiparesis group), 5 cases with tetraparesis (tetraparesis group) and 6 cases with consciousness disturbance or dementia (consciousness disturbance group), and into two groups according to the degree of midline brain shift on MRI: 14 cases of non-shifted group and 20 cases of shifted group. The average CBF of 34 patients in each region indicated a regional CBF reduction in the frontal, parietal and occipital cortices on the thin hematoma side, and in the putamen on the thick hematoma side. In the headache group, the regional CBF reduction on the thin hematoma side was found in the frontal, parietal and occipital cortices compared with the corresponding regions on the thick hematoma side, and in thalamus on the thick hematoma side. In the hemiparesis and tetraparesis groups, there was no statistically significant CBF reduction between the thick and thin hematoma sides. In the consciousness disturbance group, the CBF reduction in whole brain was remarkably significant. By the degree of the midline brain shift, the CBF reductions between the thick and thin hematoma sides were observed. Namely, in the shifted group, the CBF reductions were noted in the frontal, parietal and occipital cortices in the thin hematoma side, and in the putamen in the thick hematoma side. We concluded that the CBF reduction of bilateral chronic subdural hematoma was

  19. Simultaneous bilateral cataract surgery: economic analysis; Helsinki Simultaneous Bilateral Cataract Surgery Study Report 2.

    Science.gov (United States)

    Leivo, Tiina; Sarikkola, Anna-Ulrika; Uusitalo, Risto J; Hellstedt, Timo; Ess, Sirje-Linda; Kivelä, Tero

    2011-06-01

    To present an economic-analysis comparison of simultaneous and sequential bilateral cataract surgery. Helsinki University Eye Hospital, Helsinki, Finland. Economic analysis. Effects were estimated from data in a study in which patients were randomized to have bilateral cataract surgery on the same day (study group) or sequentially (control group). The main clinical outcomes were corrected distance visual acuity, refraction, complications, Visual Function Index-7 (VF-7) scores, and patient-rated satisfaction with vision. Health-care costs of surgeries and preoperative and postoperative visits were estimated, including the cost of staff, equipment, material, floor space, overhead, and complications. The data were obtained from staff measurements, questionnaires, internal hospital records, and accountancy. Non-health-care costs of travel, home care, and time were estimated based on questionnaires from a random subset of patients. The main economic outcome measures were cost per VF-7 score unit change and cost per patient in simultaneous versus sequential surgery. The study comprised 520 patients (241 patients included non-health-care and time cost analyses). Surgical outcomes and patient satisfaction were similar in both groups. Simultaneous cataract surgery saved 449 Euros (€) per patient in health-care costs and €739 when travel and paid home-care costs were included. The savings added up to €849 per patient when the cost of lost working time was included. Compared with sequential bilateral cataract surgery, simultaneous bilateral cataract surgery provided comparable clinical outcomes with substantial savings in health-care and non-health-care-related costs. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  20. Insect Wing Displacement Measurement Using Digital Holography

    International Nuclear Information System (INIS)

    Aguayo, Daniel D.; Mendoza Santoyo, Fernando; Torre I, Manuel H. de la; Caloca Mendez, Cristian I.

    2008-01-01

    Insects in flight have been studied with optical non destructive techniques with the purpose of using meaningful results in aerodynamics. With the availability of high resolution and large dynamic range CCD sensors the so called interferometric digital holographic technique was used to measure the surface displacement of in flight insect wings, such as butterflies. The wings were illuminated with a continuous wave Verdi laser at 532 nm, and observed with a CCD Pixelfly camera that acquire images at a rate of 11.5 frames per second at a resolution of 1392x1024 pixels and 12 Bit dynamic range. At this frame rate digital holograms of the wings were captured and processed in the usual manner, namely, each individual hologram is Fourier processed in order to find the amplitude and phase corresponding to the digital hologram. The wings displacement is obtained when subtraction between two digital holograms is performed for two different wings position, a feature applied to all consecutive frames recorded. The result of subtracting is seen as a wrapped phase fringe pattern directly related to the wing displacement. The experimental data for different butterfly flying conditions and exposure times are shown as wire mesh plots in a movie of the wings displacement

  1. Improving the phase measurement by the apodization filter in the digital holography

    Science.gov (United States)

    Chang, Shifeng; Wang, Dayong; Wang, Yunxin; Zhao, Jie; Rong, Lu

    2012-11-01

    Due to the finite size of the hologram aperture in digital holography, high frequency intensity and phase fluctuations along the edges of the images, which reduce the precision of phase measurement. In this paper, the apodization filters are applied to improve the phase measurement in the digital holography. Firstly, the experimental setup of the lensless Fourier transform digital holography is built, where the sample is a standard phase grating with the grating constant of 300μm and the depth of 150nm. Then, apodization filters are applied to phase measurement of the sample with three kinds of the window functions: Tukey window, Hanning window and Blackman window, respectively. Finally, the results were compared to the detection data given by the commercial white-light interferometer. It is shown that aperture diffraction effects can be reduced by the digital apodization, and the phase measurement with the apodization is more accurate than in the unapodized case. Meanwhile, the Blackman window function produces better effect than the other two window functions in the measurement of the standard phase grating.

  2. Prognosis of synchronous bilateral breast cancer

    DEFF Research Database (Denmark)

    Holm, Marianne; Tjønneland, Anne; Balslev, Eva

    2014-01-01

    Currently, no consistent evidence-based guidelines for the management of synchronous bilateral breast cancer (SBBC) exist and it is uncertain how presenting with SBBC affects patients' prognosis. We conducted a review of studies analyzing the association between SBBC and prognosis. The studies...... that reported adjusted effect measures were included in meta-analyses of effect of bilaterality on breast cancer mortality. From 57 initially identified records 17 studies from 11 different countries including 8,050 SBBC patients were included. The quality of the studies varied but was generally low with small...... sample sizes, and lack of consistent, detailed histo-pathological information. When doing meta-analysis on the subgroup of studies that provided adjusted effect estimates on breast cancer mortality (nine studies including 3,631 SBBC cases), we found that bilaterality in itself had a negative impact...

  3. Quantitative assessment of paretic limb dexterity and interlimb coordination during bilateral arm rehabilitation training.

    Science.gov (United States)

    Xu, Chang; Li, Siyi; Wang, Kui; Hou, Zengguang; Yu, Ningbo

    2017-07-01

    In neuro-rehabilitation after stroke, the conventional constrained induced movement therapy (CIMT) has been well-accepted. Existing bilateral trainings are mostly on mirrored symmetrical motion. However, complementary bilateral movements are dominantly involved in activities of daily living (ADLs), and functional bilateral therapies may bring better skill transfer from trainings to daily life. Neurophysiological evidence is also growing. In this work, we firstly introduce our bilateral arm training system realized with a haptic interface and a motion sensor, as well as the tasks that have been designed to train both the manipulation function of the paretic arm and coordination of bilateral upper limbs. Then, we propose quantitative measures for functional assessment of complementary bilateral training performance, including kinematic behavior indices, smoothness, submovement and bimanual coordination. After that, we describe the experiments with healthy subjects and the results with respect to these quantitative measures. Feasibility and sensitivity of the proposed indices were evaluated through comparison of unilateral and bilateral training outcomes. The proposed bilateral training system and tasks, as well as the quantitative measures, have been demonstrated effective for training and assessment of unilateral and bilateral arm functions.

  4. Measurement of three-dimensional deformations using digital holography with radial sensitivity

    Energy Technology Data Exchange (ETDEWEB)

    Kohler, Christian; Viotti, Matias R.; Albertazzi, Jr.; G. Armando

    2010-07-10

    A measurement system based on digital holography for the simultaneous measurement of out-of-plane and radial in-plane displacement fields for the assessment of residual stress is presented. Two holograms are recorded at the same time with a single image taken by a digital camera, allowing the separate evaluation of in-plane and out-of-plane movement. An axis-symmetrical diffractive optical element is used for the illumination of the object, which causes radial sensitivity vectors. By the addition and, respectively, the subtraction, of the four phase maps calculated from two camera frames, the in-plane and out-of-plane deformation of an object can be calculated separately. The device presented is suitable for high-speed, high-resolution measurement of residual stress. In addition to the setup, first measurement results and a short comparison to a mature digital speckle pattern interferometry setup are shown.

  5. Refocusing criterion via sparsity measurements in digital holography.

    Science.gov (United States)

    Memmolo, Pasquale; Paturzo, Melania; Javidi, Bahram; Netti, Paolo A; Ferraro, Pietro

    2014-08-15

    Several automatic approaches have been proposed in the past to compute the refocus distance in digital holography (DH). However most of them are based on a maximization or minimization of a suitable amplitude image contrast measure, regarded as a function of the reconstruction distance parameter. Here we show that, by using the sparsity measure coefficient regarded as a refocusing criterion in the holographic reconstruction, it is possible to recover the focus plane and, at the same time, establish the degree of sparsity of digital holograms, when samples of the diffraction Fresnel propagation integral are used as a sparse signal representation. We employ a sparsity measurement coefficient known as Gini's index thus showing for the first time, to the best of our knowledge, its application in DH, as an effective refocusing criterion. Demonstration is provided for different holographic configurations (i.e., lens and lensless apparatus) and for completely different objects (i.e., a thin pure phase microscopic object as an in vitro cell, and macroscopic puppets) preparation.

  6. Development of digital photogrammetry for measurements of displacements in underground excavation

    International Nuclear Information System (INIS)

    Ohnishi, Yuzo; Ohtsu, Hiroyasu; Nishiyama, Satoshi; Ono, Tetsu; Matsui, Hiroya

    2002-03-01

    Because deformations are important indicators of the degree of stability during construction of rock structures, monitoring of deformation is a key element of construction of tunnels and structures for the underground research laboratory. Especially in the construction and maintenance of underground excavation, monitoring of deformations is needed for obtaining useful information to control its stability. We have been developing the application of digital photogrammetry to monitoring techniques in rock structures. Photogrammetric process has undergone a remarkable evolution with its transformation into digital photogrammetry. Photogrammetry has the advantage of measuring deformation of an object by some photos with easy measurements and excellent cost performance. In this paper, we present that the digital photogrammetry can monitor the displacements of the underground excavation accurately along with a capability of real-time measurement. (author)

  7. [Reliability study in the measurement of the cusp inclination angle of a chairside digital model].

    Science.gov (United States)

    Xinggang, Liu; Xiaoxian, Chen

    2018-02-01

    This study aims to evaluate the reliability of the software Picpick in the measurement of the cusp inclination angle of a digital model. Twenty-one trimmed models were used as experimental objects. The chairside digital impression was then used for the acquisition of 3D digital models, and the software Picpick was employed for the measurement of the cusp inclination of these models. The measurements were repeated three times, and the results were compared with a gold standard, which was a manually measured experimental model cusp angle. The intraclass correlation coefficient (ICC) was calculated. The paired t test value of the two measurement methods was 0.91. The ICCs between the two measurement methods and three repeated measurements were greater than 0.9. The digital model achieved a smaller coefficient of variation (9.9%). The software Picpick is reliable in measuring the cusp inclination of a digital model.

  8. Unilateral and bilateral internal carotid artery stenosis or occlusion: a study of the secondary collateral circulation

    International Nuclear Information System (INIS)

    Zhao Yunhui; Ma Zhubin; Zhuang Lei; Liu Jianjun; Zang Jianhua

    2006-01-01

    Objective: It's a study of the collateral circulation secondary to unilateral and bilateral internal carotid artery (ICA) severe stenosis or occlusion using digital subtract angiography (DSA) and magnetic resonance angiography (MRA). Methods: Ninty-five patients with ICA stenosis or occlusion were diagnosed by DSA or MRA. Forty-four patients were assessed by DSA, and fifty-one patients were evaluated by MRA, who were divided into two groups of the unilateral and bilateral involvement. DSA, MRA findings were analyzed, by which the patterns of the collateral circulation were comparatively studied. Results: The presence rate of anterior communicating artery (AcoA) in the unilateral group on DSA and MRA was significantly higher than that in the bilateral group (P 0.05). On DSA, the presence rate of ophthalmic artery (OphA) in the unilateral and bilateral groups had no significant difference between the two groups. The augmentation rate of the OphA in the bilateral group was significantly higher than that in the unilateral group (P<0.05). The presence rate of leptomeningeal anastomosis in the bilateral group was significantly higher than that in the unilateral group on DSA and MRA (P<0.01). Conclusion: In patients with the unilateral and bilateral ICA stenosis or occlusion, the collateral circulation formats in different patterns. The major collateral pathways secondary to the unilateral ICA stenosis or occlusion are AcoA and ispilateral PCoA, while to the bilateral ICA stenosis or' occlusion are PCoA, OPhA, and leptomeningeal anastomosis. (authors)

  9. Application of digital beam position processor Libera on tune measurement

    International Nuclear Information System (INIS)

    Zhang Chunhui; Sun Baogen; Cao Yong; Lu Ping; Li Jihao

    2006-01-01

    Digital signal processing (DSP) is widely used in the field of beam diagnostics. Especially, DSP achieves very good performance in beam position signal analysis and betatron tune measurement. In Hefei light source, when beam was excited by narrow-band Gaussian white nose, Libera, a digital beam position processor, was used to process the signals from beam position monitor (BPM), which contained betatron oscillation. Fast Fourier transform (FFT) was applied to finding out betatron resonance frequency, from which the decimal part of betatron oscillation tune was calculated. By this means, the measure of horizontal tune was 3.5352 and the measure of vertical tune is 2.6299. (authors)

  10. JMorph: Software for performing rapid morphometric measurements on digital images of fossil assemblages

    Science.gov (United States)

    Lelièvre, Peter G.; Grey, Melissa

    2017-08-01

    Quantitative morphometric analyses of form are widely used in palaeontology, especially for taxonomic and evolutionary research. These analyses can involve several measurements performed on hundreds or even thousands of samples. Performing measurements of size and shape on large assemblages of macro- or microfossil samples is generally infeasible or impossible with traditional instruments such as vernier calipers. Instead, digital image processing software is required to perform measurements via suitable digital images of samples. Many software packages exist for morphometric analyses but there is not much available for the integral stage of data collection, particularly for the measurement of the outlines of samples. Some software exists to automatically detect the outline of a fossil sample from a digital image. However, automatic outline detection methods may perform inadequately when samples have incomplete outlines or images contain poor contrast between the sample and staging background. Hence, a manual digitization approach may be the only option. We are not aware of any software packages that are designed specifically for efficient digital measurement of fossil assemblages with numerous samples, especially for the purposes of manual outline analysis. Throughout several previous studies, we have developed a new software tool, JMorph, that is custom-built for that task. JMorph provides the means to perform many different types of measurements, which we describe in this manuscript. We focus on JMorph's ability to rapidly and accurately digitize the outlines of fossils. JMorph is freely available from the authors.

  11. Trajectory and velocity measurement of a particle in spray by digital holography

    Energy Technology Data Exchange (ETDEWEB)

    Lue Qieni; Chen Yiliang; Yuan Rui; Ge Baozhen; Gao Yan; Zhang Yimo

    2009-12-20

    We present a method for the trajectory and the velocity measurement of a particle in spray by digital holography. Based on multiple exposure digital in-line holography, a sequence of digital holograms of a dynamic spray particle field at different times are recorded with a CW laser and a high-speed CCD. The time evolution of the serial positions of particles, i.e., the motion trajectories of the particles, is obtained by numerically reconstructing the synthetic hologram of a sequence of digital holograms. The center coordinate (x,y) of each particle image can be extracted using a Hough transform and subpixel precision computing, and the velocity of an individual particle can also be obtained, which is then applied to measuring the velocity of diesel spray and alcohol spray. The research shows that the method presented in this paper for measuring spray field is feasible.

  12. Bilateral symmetry detection on the basis of Scale Invariant Feature Transform.

    Directory of Open Access Journals (Sweden)

    Habib Akbar

    Full Text Available The automatic detection of bilateral symmetry is a challenging task in computer vision and pattern recognition. This paper presents an approach for the detection of bilateral symmetry in digital single object images. Our method relies on the extraction of Scale Invariant Feature Transform (SIFT based feature points, which serves as the basis for the ascertainment of the centroid of the object; the latter being the origin under the Cartesian coordinate system to be converted to the polar coordinate system in order to facilitate the selection symmetric coordinate pairs. This is followed by comparing the gradient magnitude and orientation of the corresponding points to evaluate the amount of symmetry exhibited by each pair of points. The experimental results show that our approach draw the symmetry line accurately, provided that the observed centroid point is true.

  13. [Reconstruction and measurement of a digital dental model using grating projection and reverse engineering].

    Science.gov (United States)

    Zhenzhen, Wang; Yi, Lu; Jun, Song; Jun, Chen; Qin, Zhou

    2015-02-01

    This work lays the foundation for establishing a digital model database with normal occlusion. A digital dental cast is acquired through grating projection, and model features are measured through reverse engineering. The grating projection system controlled by a computer was projected onto the surface of a normal dental model. Three-dimensional contour data were obtained through multi-angle shooting. A three-dimensional model was constructed, and the model features were analyzed by using reverse engineering. The digital model was compared with the plaster model to determine the accuracy of the measurement system. The structure of three-dimensional reconstruction model was clear. The digital models of two measurements exhibited no significant difference (P > 0.05). When digital and plaster models were measured, we found that the crown length and arch width were not statistically different (P > 0.05), whereas the difference between the crown width and arch length was statistically significant (P model by using the grating projection technique and reverse engineering can be used for dental model measurement in clinic al and scientific research and can provide a scientific method for establishing a digital model database with normal occlusion.

  14. Creativity in the Age of Technology: Measuring the Digital Creativity of Millennials

    Science.gov (United States)

    Hoffmann, Jessica; Ivcevic, Zorana; Brackett, Marc

    2016-01-01

    Digital technology and its many uses form an emerging domain of creative expression for adolescents and young adults. To date, measures of self-reported creative behavior cover more traditional forms of creativity, including visual art, music, or writing, but do not include creativity in the digital domain. This article introduces a new measure,…

  15. Fine Metal Mask 3-Dimensional Measurement by using Scanning Digital Holographic Microscope

    Science.gov (United States)

    Shin, Sanghoon; Yu, Younghun

    2018-04-01

    For three-dimensional microscopy, fast and high axial resolution are very important. Extending the depth of field for digital holographic is necessary for three-dimensional measurements of thick samples. We propose an optical sectioning method for optical scanning digital holography that is performed in the frequency domain by spatial filtering of a reconstructed amplitude image. We established a scanning dual-wavelength off-axis digital holographic microscope to measure samples that exhibit a large amount of coherent noise and a thickness larger than the depth of focus of the objective lens. As a demonstration, we performed a three-dimensional measurement of a fine metal mask with a reconstructed sectional phase image and filtering with a reconstructed amplitude image.

  16. Clinical study of cerebral blood flow in bilateral chronic subdural hematoma measured by {sup 99m}Tc-HMPAO SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Okuyama, Tohru; Saito, Koji; Fukuyama, Kohichi; Yamamoto, Kouki; Morimoto, Mamoru [Kushiro Neurosurgical Hospital, Hokkaido (Japan); Aburano, Tamio

    2000-08-01

    Cerebral blood flow (CBF) in 34 patients with bilateral chronic subdural hematoma was measured by {sup 99m}Tc-HMPAO SPECT before operation. The regional CBF was measured in 26 regions of the 10 cortical regions, putamen, thalamus and cerebellar hemisphere on both sides. According to the thickness of subdural hematoma, the thicker hematoma side was measured and examined as the thick hematoma side, and the other side as the thin hematoma side. Thirty four cases with bilateral chronic subdural hematoma were classified into four groups on the basis of clinical symptoms :13 cases with headache (headache group), 10 cases with hemiparesis (hemiparesis group), 5 cases with tetraparesis (tetraparesis group) and 6 cases with consciousness disturbance or dementia (consciousness disturbance group), and into two groups according to the degree of midline brain shift on MRI: 14 cases of non-shifted group and 20 cases of shifted group. The average CBF of 34 patients in each region indicated a regional CBF reduction in the frontal, parietal and occipital cortices on the thin hematoma side, and in the putamen on the thick hematoma side. In the headache group, the regional CBF reduction on the thin hematoma side was found in the frontal, parietal and occipital cortices compared with the corresponding regions on the thick hematoma side, and in thalamus on the thick hematoma side. In the hemiparesis and tetraparesis groups, there was no statistically significant CBF reduction between the thick and thin hematoma sides. In the consciousness disturbance group, the CBF reduction in whole brain was remarkably significant. By the degree of the midline brain shift, the CBF reductions between the thick and thin hematoma sides were observed. Namely, in the shifted group, the CBF reductions were noted in the frontal, parietal and occipital cortices in the thin hematoma side, and in the putamen in the thick hematoma side. We concluded that the CBF reduction of bilateral chronic subdural hematoma

  17. Binaural Speech Understanding With Bilateral Cochlear Implants in Reverberation.

    Science.gov (United States)

    Kokkinakis, Kostas

    2018-03-08

    The purpose of this study was to investigate whether bilateral cochlear implant (CI) listeners who are fitted with clinical processors are able to benefit from binaural advantages under reverberant conditions. Another aim of this contribution was to determine whether the magnitude of each binaural advantage observed inside a highly reverberant environment differs significantly from the magnitude measured in a near-anechoic environment. Ten adults with postlingual deafness who are bilateral CI users fitted with either Nucleus 5 or Nucleus 6 clinical sound processors (Cochlear Corporation) participated in this study. Speech reception thresholds were measured in sound field and 2 different reverberation conditions (0.06 and 0.6 s) as a function of the listening condition (left, right, both) and the noise spatial location (left, front, right). The presence of the binaural effects of head-shadow, squelch, summation, and spatial release from masking in the 2 different reverberation conditions tested was determined using nonparametric statistical analysis. In the bilateral population tested, when the ambient reverberation time was equal to 0.6 s, results indicated strong positive effects of head-shadow and a weaker spatial release from masking advantage, whereas binaural squelch and summation contributed no statistically significant benefit to bilateral performance under this acoustic condition. These findings are consistent with those of previous studies, which have demonstrated that head-shadow yields the most pronounced advantage in noise. The finding that spatial release from masking produced little to almost no benefit in bilateral listeners is consistent with the hypothesis that additive reverberation degrades spatial cues and negatively affects binaural performance. The magnitude of 4 different binaural advantages was measured on the same group of bilateral CI subjects fitted with clinical processors in 2 different reverberation conditions. The results of this work

  18. Bilateral ce-MR angiography of the hands at 3.0 T and 1.5 T: intraindividual comparison of quantitative and qualitative image parameters in healthy volunteers

    International Nuclear Information System (INIS)

    Winterer, Jan T.; Markl, Michael; Frydrychowicz, Alexander; Bley, Thorsten A.; Langer, Mathias; Moske-Eick, Olaf

    2008-01-01

    The purpose of this study was to determine the benefit of bilateral contrast-enhanced MR angiography (ce-MRA) of the hands at 3.0 Tesla (T) compared with an established 1.5-T technique in healthy volunteers. Intraindividual bilateral ce-MRA of the hands was performed at 1.5 T and 3.0 T in 14 healthy volunteers using a timed ultra-fast GRE sequence featuring parallel acquisition. The evaluation comprised measurement of the vessel signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR), rating of the image quality and the assessment of artefacts and venous contamination. At 3.0 T, SNR improved up to 95% and CNR up to 129%. The image quality of the larger inflow arteries, the palm arches and common digital arteries was good or sufficient at either magnetic field strengths. However, 3.0-T MRA was clearly superior in the depiction of the digital arteries. Ce-MRA of the hand clearly profits from the use of 3.0 T. Compared with 1.5 T, a substantial increase of CNR is found resulting in a significantly better delineation of the small digital arteries. Saturation affects more the SNR of the perivascular tissue than the contrast-enhanced blood, and thus leads to a marked increase of CNR at 3.0. (orig.)

  19. Digital holographic setups for phase object measurements in micro and macro scale

    Directory of Open Access Journals (Sweden)

    Lédl Vít

    2015-01-01

    Full Text Available The measurement of properties of so called phase objects is being solved for more than one Century starting probably with schlieren technique 1. Classical interferometry served as a great measurement tool for several decades and was replaced by holographic interferometry, which disposes with many benefits when compared to classical interferometry. Holographic interferometry undergone an enormous development in last decade when digital holography has been established as a standard technique and most of the drawbacks were solved. The paper deals with scope of the huge applicability of digital holographic interferometry in heat and mass transfer measurement from micro to macro scale and from simple 2D measurement up to complex tomographic techniques. Recently the very complex experimental setups are under development in our labs combining many techniques leading to digital holographic micro tomography methods.

  20. Objective assessment of actual chewing side by measurement of bilateral masseter muscle electromyography.

    Science.gov (United States)

    Yamasaki, Yo; Kuwatsuru, Rika; Tsukiyama, Yoshihiro; Matsumoto, Hiroshi; Oki, Kyosuke; Koyano, Kiyoshi

    2015-12-01

    The aim of this study was to examine the validity of objective assessment of actual chewing side by measurement of electromyographic (EMG) activity of the bilateral masseter muscles upon chewing test foods. The sample consisted of 19 healthy, dentate individuals. The subjects were asked to chew three types of test foods (peanuts, beef jerky, and chewing gum) for 10 strokes on the right side and then on the left side, and instructed to perform maximum voluntary clenching for 3s, three times. EMG activity from the bilateral masseter muscles was recorded. The data were collected in three different days. The root mean square EMG amplitude obtained from the maximum clenching task was used as the maximum voluntary contraction (MVC). Then, the level of amplitude against the MVC (%MVC) was calculated for the right and left sides on each stroke. The side with the larger %MVC value was judged as the chewing side, and the concordance rates (CRs) for the instructed chewing side (ICS) and the judged chewing side (JCS) were calculated. Intraclass correlation coefficients (ICCs) of the CRs were calculated to evaluate the reproducibility of the method. High CRs between the ICS and JCS for each test food were recognized. There were significant ICCs for beef jerky (R=0.761, Pchewing gum (R=0.785, Pchewing side during mastication. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. Difference between manual and digital measurements of dental arches of orthodontic patients.

    Science.gov (United States)

    Jiménez-Gayosso, Sandra Isabel; Lara-Carrillo, Edith; López-González, Saraí; Medina-Solís, Carlo Eduardo; Scougall-Vilchis, Rogelio José; Hernández-Martínez, César Tadeo; Colomé-Ruiz, Gabriel Eduardo; Escoffié-Ramirez, Mauricio

    2018-06-01

    The objective of this study was to compare the differences between the measurements performed manually to those obtained using a digital model scanner of patients with orthodontic treatment.A cross-sectional study was performed in a sample of 30 study models from patients with permanent dentition who attended a university clinic between January 2010 and December 2015. For the digital measurement, a Maestro 3D Ortho Studio scanner (Italy) was used and Mitutoyo electronic Vernier calipers (Kawasaki, Japan) were used for manual measurement. The outcome variables were the measurements for maxillary intercanine width, mandibular intercanine width, maxillary intermolar width, mandibular intermolar width, overjet, overbite, maxillary arch perimeter, mandibular arch perimeter, and palate height. The independent variables, besides age and sex, were a series of arc characteristics. The Student t test, paired Student t test, and Pearson correlation in SPSS version 19 were used for the analysis.Of the models, 60% were from women. Two of nine measurements for pre-treatment and 6 of 9 measurements for post-treatment showed a difference. The variables that were different between the manual and digital measurements in the pre-treatment were maxillary intermolar width and palate height (P manually and digitally showed certain similarities for both vertical and transverse measurements. There are many advantages offered to the orthodontist, such as easy storage; savings in time and space; facilitating the reproducibility of information; and conferring the security of not deteriorating over time. Its main disadvantage is the cost.

  2. Digital PCR as a tool to measure HIV persistence.

    Science.gov (United States)

    Rutsaert, Sofie; Bosman, Kobus; Trypsteen, Wim; Nijhuis, Monique; Vandekerckhove, Linos

    2018-01-30

    Although antiretroviral therapy is able to suppress HIV replication in infected patients, the virus persists and rebounds when treatment is stopped. In order to find a cure that can eradicate the latent reservoir, one must be able to quantify the persisting virus. Traditionally, HIV persistence studies have used real-time PCR (qPCR) to measure the viral reservoir represented by HIV DNA and RNA. Most recently, digital PCR is gaining popularity as a novel approach to nucleic acid quantification as it allows for absolute target quantification. Various commercial digital PCR platforms are nowadays available that implement the principle of digital PCR, of which Bio-Rad's QX200 ddPCR is currently the most used platform in HIV research. Quantification of HIV by digital PCR is proving to be a valuable improvement over qPCR as it is argued to have a higher robustness to mismatches between the primers-probe set and heterogeneous HIV, and forfeits the need for a standard curve, both of which are known to complicate reliable quantification. However, currently available digital PCR platforms occasionally struggle with unexplained false-positive partitions, and reliable segregation between positive and negative droplets remains disputed. Future developments and advancements of the digital PCR technology are promising to aid in the accurate quantification and characterization of the persistent HIV reservoir.

  3. Tinnitus after Simultaneous and Sequential Bilateral Cochlear Implantation.

    Science.gov (United States)

    Ramakers, Geerte G J; Kraaijenga, Véronique J C; Smulders, Yvette E; van Zon, Alice; Stegeman, Inge; Stokroos, Robert J; Free, Rolien H; Frijns, Johan H M; Huinck, Wendy J; Van Zanten, Gijsbert A; Grolman, Wilko

    2017-01-01

    There is an ongoing global discussion on whether or not bilateral cochlear implantation should be standard care for bilateral deafness. Contrary to unilateral cochlear implantation, however, little is known about the effect of bilateral cochlear implantation on tinnitus. To investigate tinnitus outcomes 1 year after bilateral cochlear implantation. Secondarily, to compare tinnitus outcomes between simultaneous and sequential bilateral cochlear implantation and to investigate long-term follow-up (3 years). This study is a secondary analysis as part of a multicenter randomized controlled trial. Thirty-eight postlingually deafened adults were included in the original trial, in which the presence of tinnitus was not an inclusion criterion. All participants received cochlear implants (CIs) because of profound hearing loss. Nineteen participants received bilateral CIs simultaneously and 19 participants received bilateral CIs sequentially with an inter-implant interval of 2 years. The prevalence and severity of tinnitus before and after simultaneous and sequential bilateral cochlear implantation were measured preoperatively and each year after implantation with the Tinnitus Handicap Inventory (THI) and Tinnitus Questionnaire (TQ). The prevalence of preoperative tinnitus was 42% (16/38). One year after bilateral implantation, there was a median difference of -8 (inter-quartile range (IQR): -28 to 4) in THI score and -9 (IQR: -17 to -9) in TQ score in the participants with preoperative tinnitus. Induction of tinnitus occurred in five participants, all in the simultaneous group, in the year after bilateral implantation. Although the preoperative and also the postoperative median THI and TQ scores were higher in the simultaneous group, the median difference scores were equal in both groups. In the simultaneous group, tinnitus scores fluctuated in the 3 years after implantation. In the sequential group, four patients had an additional benefit of the second CI: a total

  4. Digital instrument for reactivity measurements in a nuclear reactor

    Energy Technology Data Exchange (ETDEWEB)

    Chwaszczewski, S [Institute of Nuclear Research, Warsaw (Poland)

    1979-07-01

    An instrument for digital determination of the reactivity in nuclear reactors is described. It is based on the CAMAC standard apparatus, suitable for the use of pulse or current type neutron detectors and operates with prompt response and an output signal proportional to the core neutron flux. The measured data of neutron flux and reactivity can be registered by a digital display unit, an indicator, or, by request of the operator, a paper type punch. The algorithms used for reactivity calculation are considered and the results of numerical studies on those algorithms are discussed. The instrument has been used for determining the reactivity of the control elements in the fast-thermal assembly ANNA and in the research reactor MARIA. Some results of these measurements are given.

  5. Measurement of digital blood pressure after local cooling

    DEFF Research Database (Denmark)

    Nielsen, S L; Lassen, N A

    1977-01-01

    A double-inlet plastic cuff was designed for local cooling and systolic blood pressure measurement on the middle phalanx of the fingers. With a tourniquet on the proximal phalanx of one finger, cooling for 5 min made the digital artery temperature equal the skin temperature. The difference between...... the systolic pressure in a control finger and in the cooled finger give the reopening pressure in the digital arteries. At 30, 25, 20, 15, and 10 degrees C, respectively the percent decrease of the finger pressure was 0.2 (0.2), 1.5 (2.5), 8.5 (3.7), 11.4 (3.4), and 15.3 (3.1) in normal young women...

  6. Digital flexor musculotendinous contracture in two Devon Rex cats.

    Science.gov (United States)

    Thom, Leonie K; Pool, Roy R; Malik, Richard

    2017-03-01

    Clinical summary: A 13-year-old, spayed Devon Rex with unilateral digital flexor musculotendinous contracture of the forelimb was treated by surgical tenotomy. The condition improved transiently, but recurred rapidly and became bilateral. Histopathologic analysis of necropsy tissues resulted in a morphologic diagnosis of fibromyositis of the antebrachial muscles causing contracture and flexural deformity of the carpi and phalanges of both thoracic limbs. A search for similar cases yielded the clinical notes of a second cat, a 10-year-old, spayed Devon Rex, also with bilateral disease. This second case responded well to surgical tenotomy but tissue biopsies were not obtained to permit microscopic assessment of the underlying pathologic process. Relevance and novel information: Acquired and permanent contracture of the digital flexor muscles and/or tendons of the forelimbs is a rare and poorly described condition of cats. The very limited number of documented cases describing disease affecting one or more digits (but not the carpus) infers a causal link with onychectomy, but reported histopathologic changes have been limited to the tendons. The two cases described in this report suffered contracture of the carpus and all digits bilaterally, one without previous onychectomy and the other 9 years after onychectomy. There were novel histopathologic findings in the muscles of the one case for which biopsy material was available. Information gained from these two cases provides a new perspective for the investigation and treatment of future cases. Specifically, consideration should be given to an underlying immune-mediated myopathic process and a possible genetic predisposition in the Devon Rex breed. Currently, the poorly understood etiopathogenesis hinders our ability to definitively recommend treatment options, which might include corticosteroids and other forms of immunosuppressive therapy.

  7. Measurement-Device Independency Analysis of Continuous-Variable Quantum Digital Signature

    Directory of Open Access Journals (Sweden)

    Tao Shang

    2018-04-01

    Full Text Available With the practical implementation of continuous-variable quantum cryptographic protocols, security problems resulting from measurement-device loopholes are being given increasing attention. At present, research on measurement-device independency analysis is limited in quantum key distribution protocols, while there exist different security problems for different protocols. Considering the importance of quantum digital signature in quantum cryptography, in this paper, we attempt to analyze the measurement-device independency of continuous-variable quantum digital signature, especially continuous-variable quantum homomorphic signature. Firstly, we calculate the upper bound of the error rate of a protocol. If it is negligible on condition that all measurement devices are untrusted, the protocol is deemed to be measurement-device-independent. Then, we simplify the calculation by using the characteristics of continuous variables and prove the measurement-device independency of the protocol according to the calculation result. In addition, the proposed analysis method can be extended to other quantum cryptographic protocols besides continuous-variable quantum homomorphic signature.

  8. Bilateral Complete and Incomplete Fusion of Incisors and its Management.

    Science.gov (United States)

    Da Costa, Godwin Clovis; Chalakkal, Paul; De Souza, Neil; Gavhane, Sanket

    2017-01-01

    This case report highlights the management of a case of bilateral complete and incomplete fusion of maxillary incisors in a 10-year-old child. A mock-up was done on the diagnostic cast. Pretreatment esthetic evaluation was done using bis-acryl composite temporaries which were transferred intraorally from the diagnostic cast using a putty index. An incisal overlap veneer preparation was done, following which, an IPS e-max veneer was cemented. A digital mock-up was carried out using the Adobe Photoshop and Corel Draw softwares to aid in laboratorial fabrication of the veneer.

  9. Bilateral and unilateral ECT: effects on verbal and nonverbal memory.

    Science.gov (United States)

    Squire, S R; Slater, P C

    1978-11-01

    The memory loss associated with bilateral and nondominant unilateral ECT was assessed with verbal memory tests known to be sensitive to left temporal lobe dysfunction and with nonverbal memory tests known to be sensitive to right temporal lobe dysfunction. Bilateral ECT markedly impaired delayed retention of verbal and nonverbal material. Right unilateral ECT impaired delayed retention of nonverbal material without measurably affecting retention of verbal material. Nonverbal memory was affected less by right unilateral ECT than by bilateral ECT. These findings, taken together with a consideration of the clinical efficacy of the two types of treatment, make what appears to be a conclusive case for unilateral over bilateral ECT.

  10. Comarability of digital and analouge x-rays for migration measurements with EBRA

    International Nuclear Information System (INIS)

    Brabec, E.

    2001-02-01

    EBRA is a computer supported method for measuring the migration of total hip prostheses by using consecutive standard X-rays of the pelvis. PACS is a picture archiving and communication system used to handle digitally taken X-rays. After the installation of a PACS at the University Clinic of Innsbruck it was impossible to compare the digital pictures with the former analogue pictures with EBRA, as they have different scales. By introducing a calibrating step into the EBRA-program it was possible to do measurements on series of pictures containing digital pictures as well as analogue ones. For displaying the failure of EBRA caused by different radiological techniques we did measurements on a series of consecutive X-rays taken of a model made of acrylic glass and simulating the relevant anatomic structures by screws. The migration of the implant was simulated by shifting it in two directions. Whilst using analogue and digital radiological techniques for taking X-rays, the difference in measurement errors of both techniques was studied. The reliable comparability of X-rays of every format is an absolute necessity for continuing measurements of migration after changing the technique of taking X-rays. The average measurement error of all studied formats of pictures was 0.04 mm (Stdev. 0.11 mm). Though, by using the calibration tool of EBRA migration measurement on X-rays with different formats is possible within the same accuracy. (author)

  11. The measurement of the modal strain fields using digital shearography

    Directory of Open Access Journals (Sweden)

    Gomes J.M.

    2010-06-01

    Full Text Available This work presents a Michelson shearography interferometer configuration associated with stroboscopic double illumination technique for the measurement of modal rotation fields and their strain fields on a clamped circular aluminium plate. The speckle pattern is frozen by the synchronization between the LASER illumination and the modal vibration of the object. The quantitative evaluation is performed for each digital shearogram using a time modulation technique. The setup of double illumination LASER with out-of-plane opposite sensitivity allows the two phase maps measurement of the modal spatial gradient. The modal rotation and strain fields are extracted by the combination of this two digital phase maps. Image processing techniques are applied on the phase maps to obtain full-field measurements using a dedicated post-processing algorithm. Finally, is presented a comparison between the experimental measurement and the numerical solution.

  12. Digital spectrometer for coincidence measurement of Doppler broadening of positron annihilation radiation

    International Nuclear Information System (INIS)

    Cizek, J.; Vlcek, M.; Prochazka, I.

    2010-01-01

    High-resolution digital coincidence Doppler broadening spectrometer equipped with two high-purity Ge detectors and two-channel 12-bit fast digitizer was developed and tested in this work. Two configurations were compared: (i) semi-digital setup which uses active analogue shaping of detector pulses prior to digitization to improve signal-to-noise ratio, and (ii) pure-digital setup which samples detector pulses directly. Software procedure developed for analysis of sampled waveforms, i.e. precise determination of energy of detected photon and rejection of distorted pulses, is described. Performance of digital coincidence spectrometer was compared with traditional analogue setup connected to the same detectors. It was found that digital spectrometer enables to achieve better energy resolution than in traditional analogue setup. Moreover, in digital configuration one has better control over shape of the signal. This allows efficient elimination of undesired distorted or damaged waveforms and to obtain spectrum of better clarity. The superior parameters of new digital coincidence Doppler broadening spectrometer are demonstrated by benchmark measurements of well defined Fe and Al specimens and also by the detection of rare annihilation in flight events.

  13. Bilateral Hallux Valgus: A Utility Outcome Score Assessment.

    Science.gov (United States)

    Makhdom, Asim M; Sinno, Hani; Aldebeyan, Sultan; Cota, Adam; Hamdy, Reggie Charles; Alzahrani, Mohammad; Janelle, Chantal

    2016-01-01

    Hallux valgus is the most common forefoot problem in adults. Although it can cause considerable disability and affect the quality of life of those affected, many patients seek medical attention because of cosmetic concerns. Our aim was to objectively measure the perceived health burden of living with bilateral hallux valgus. Previously validated utility outcome measures, including the visual analog scale, time trade-off, and standard gamble tests, were used to quantify the health burden for single-eye blindness, double-eye blindness, and bilateral hallux valgus in 103 healthy subjects using an online survey. The Student t test and linear regression analysis were used for statistical analysis. The mean visual analog scale, time trade-off, and standard gamble scores for bilateral hallux valgus were 0.86 ± 1.6, 0.95 ± 0.5, and 0.95 ± 0.14, respectively. These were significantly greater than the utility scores for single-eye and double-eye blindness (p hallux valgus. In conclusion, we have objectively demonstrated the effect of living with bilateral hallux valgus deformities. Our sample population reported being willing to undergo a procedure with a 5% mortality rate and sacrifice 1.8 years of life to attain perfect health and avoid the bilateral hallux valgus health state. Our findings will guide us in counseling our patients and understanding how they perceive their foot deformity. Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  14. Tinnitus after Simultaneous and Sequential Bilateral Cochlear Implantation

    Directory of Open Access Journals (Sweden)

    Geerte G. J. Ramakers

    2017-11-01

    Full Text Available ImportanceThere is an ongoing global discussion on whether or not bilateral cochlear implantation should be standard care for bilateral deafness. Contrary to unilateral cochlear implantation, however, little is known about the effect of bilateral cochlear implantation on tinnitus.ObjectiveTo investigate tinnitus outcomes 1 year after bilateral cochlear implantation. Secondarily, to compare tinnitus outcomes between simultaneous and sequential bilateral cochlear implantation and to investigate long-term follow-up (3 years.Study designThis study is a secondary analysis as part of a multicenter randomized controlled trial.MethodsThirty-eight postlingually deafened adults were included in the original trial, in which the presence of tinnitus was not an inclusion criterion. All participants received cochlear implants (CIs because of profound hearing loss. Nineteen participants received bilateral CIs simultaneously and 19 participants received bilateral CIs sequentially with an inter-implant interval of 2 years. The prevalence and severity of tinnitus before and after simultaneous and sequential bilateral cochlear implantation were measured preoperatively and each year after implantation with the Tinnitus Handicap Inventory (THI and Tinnitus Questionnaire (TQ.ResultsThe prevalence of preoperative tinnitus was 42% (16/38. One year after bilateral implantation, there was a median difference of −8 (inter-quartile range (IQR: −28 to 4 in THI score and −9 (IQR: −17 to −9 in TQ score in the participants with preoperative tinnitus. Induction of tinnitus occurred in five participants, all in the simultaneous group, in the year after bilateral implantation. Although the preoperative and also the postoperative median THI and TQ scores were higher in the simultaneous group, the median difference scores were equal in both groups. In the simultaneous group, tinnitus scores fluctuated in the 3 years after implantation. In the sequential group

  15. Bilateral herpes zoster

    OpenAIRE

    Singh K; Bajaj A; Dwivedi N; Merchery A

    1993-01-01

    A case of bilateral herpes zoster of lumbosacral region is reported in association with diabetes mellitus in a 55 years old female. The case is of interest due to bilateral distribution which is rare and sacral region involvement which is quite uncommon.

  16. A digital instantaneous frequency measurement technique utilising high speed analogue to digital converters and field programmable gate arrays

    CSIR Research Space (South Africa)

    Herselman, PLR

    2007-09-01

    Full Text Available In modern information and sensor systems, the timely estimation of the carrier frequency of received signals is of critical importance. This paper presents a digital instantaneous frequency measurement (DIFM) technique, which can measure the carrier...

  17. Procedure to determine the two channel timing measurement accuracy and precision of a digital oscilloscope

    International Nuclear Information System (INIS)

    Johnson, M.; Matulik, M.

    1994-01-01

    The digital oscilloscope allows one to make numerous timing measurements, but just how good are those measurements? This document describes a procedure which can be used to determine the accuracy and precision to which a digital oscilloscope can make various two channel timing measurements

  18. Bilateral Testicular Tumors Resulting in Recurrent Cushing Disease After Bilateral Adrenalectomy

    NARCIS (Netherlands)

    Puar, T.; Engels, M.; Herwaarden, A.E. van; Sweep, F.C.; Hulsbergen-van de Kaa, C.A.; Kamphuis-van Ulzen, K.; Chortis, V.; Arlt, W.; Stikkelbroeck, N.; Claahsen-van der Grinten, H.L.; Hermus, A.R.M.M.

    2017-01-01

    Context: Recurrence of hypercortisolism in patients after bilateral adrenalectomy for Cushing disease is extremely rare. Patient: We present a 27-year-old man who previously underwent bilateral adrenalectomy for Cushing disease with complete clinical resolution. Cushingoid features recurred 12 years

  19. Bilateral herpes zoster

    Directory of Open Access Journals (Sweden)

    Singh K

    1993-01-01

    Full Text Available A case of bilateral herpes zoster of lumbosacral region is reported in association with diabetes mellitus in a 55 years old female. The case is of interest due to bilateral distribution which is rare and sacral region involvement which is quite uncommon.

  20. An accelerometry-based methodology for assessment of real-world bilateral upper extremity activity.

    Directory of Open Access Journals (Sweden)

    Ryan R Bailey

    Full Text Available The use of both upper extremities (UE is necessary for the completion of many everyday tasks. Few clinical assessments measure the abilities of the UEs to work together; rather, they assess unilateral function and compare it between affected and unaffected UEs. Furthermore, clinical assessments are unable to measure function that occurs in the real-world, outside the clinic. This study examines the validity of an innovative approach to assess real-world bilateral UE activity using accelerometry.Seventy-four neurologically intact adults completed ten tasks (donning/doffing shoes, grooming, stacking boxes, cutting playdough, folding towels, writing, unilateral sorting, bilateral sorting, unilateral typing, and bilateral typing while wearing accelerometers on both wrists. Two variables, the Bilateral Magnitude and Magnitude Ratio, were derived from accelerometry data to distinguish between high- and low-intensity tasks, and between bilateral and unilateral tasks. Estimated energy expenditure and time spent in simultaneous UE activity for each task were also calculated.The Bilateral Magnitude distinguished between high- and low-intensity tasks, and the Magnitude Ratio distinguished between unilateral and bilateral UE tasks. The Bilateral Magnitude was strongly correlated with estimated energy expenditure (ρ = 0.74, p<0.02, and the Magnitude Ratio was strongly correlated with time spent in simultaneous UE activity (ρ = 0.93, p<0.01 across tasks.These results demonstrate face validity and construct validity of this methodology to quantify bilateral UE activity during the performance of everyday tasks performed in a laboratory setting, and can now be used to assess bilateral UE activity in real-world environments.

  1. Hypofractionated Stereotactic Radiosurgery in a Large Bilateral Thalamic and Basal Ganglia Arteriovenous Malformation

    Directory of Open Access Journals (Sweden)

    Janet Lee

    2013-01-01

    Full Text Available Purpose. Arteriovenous malformations (AVMs in the basal ganglia and thalamus have a more aggressive natural history with a higher morbidity and mortality than AVMs in other locations. Optimal treatment—complete obliteration without new neurological deficits—is often challenging. We present a patient with a large bilateral basal ganglia and thalamic AVM successfully treated with hypofractionated stereotactic radiosurgery (HFSRS with intensity modulated radiotherapy (IMRT. Methods. The patient was treated with hypofractionated stereotactic radiosurgery to 30 Gy at margin in 5 fractions of 9 static fields with a minimultileaf collimator and intensity modulated radiotherapy. Results. At 10 months following treatment, digital subtraction angiography showed complete obliteration of the AVM. Conclusions. Large bilateral thalamic and basal ganglia AVMs can be successfully treated with complete obliteration by HFSRS with IMRT with relatively limited toxicity. Appropriate caution is recommended.

  2. Association between renal cystic lesions and bilateral Wilms' tumours

    Energy Technology Data Exchange (ETDEWEB)

    Simanovsky, Natalia; Hiller, Nurith [Hadassah-Hebrew University Medical Center at Mt Scopus, Department of Medical Imaging, POB 12000, Jerusalem (Israel); Revel-Vilk, Shoshana; Weintraub, Michael [Hadassah-Hebrew University Medical Center, Department of Pediatric Hematology/ Oncology, Jerusalem (Israel)

    2016-06-15

    Evaluate a potential association between Wilms' tumour (WT) and renal cystic lesions. Digital records and imaging files of consecutive patients diagnosed with WT between 2004 and 2014 were retrospectively reviewed under an Institutional Review Board waiver of informed consent. The locations of renal cysts seen on US, CT, and/or MRI were recorded and compared with the locations of newly developed WT. A total of 48 patients (mean age 3 years 9 months) presented with newly diagnosed WT in the study period. Mean follow-up was 4.5 (range 1-10) years. WT was unilateral in 40 children, bilateral in 8. Renal cysts were identified in only one of the forty patients (2.5 %) with unilateral disease - in the contralateral kidney. In contrast, renal cysts were found in seven of eight patients with bilateral WT (87.5 %), in two of whom, new tumours developed in the same location where cysts had been seen on previous imaging studies. Renal cystic lesions in patients with Wilms' tumour should be regarded as potential tumour precursors, and followed with frequent imaging. (orig.)

  3. Bilateral complete and incomplete fusion of incisors and its management

    Directory of Open Access Journals (Sweden)

    Godwin Clovis Da Costa

    2017-01-01

    Full Text Available This case report highlights the management of a case of bilateral complete and incomplete fusion of maxillary incisors in a 10-year-old child. A mock-up was done on the diagnostic cast. Pretreatment esthetic evaluation was done using bis-acryl composite temporaries which were transferred intraorally from the diagnostic cast using a putty index. An incisal overlap veneer preparation was done, following which, an IPS e-max veneer was cemented. A digital mock-up was carried out using the Adobe Photoshop and Corel Draw softwares to aid in laboratorial fabrication of the veneer.

  4. Bilateral breast carcinoma

    International Nuclear Information System (INIS)

    Kim, Eung Jo; Oh, Ki Keun

    1990-01-01

    We evaluate 311 breast cancer patients admitted to Yong Dong Severance Hospital Between October 1st 1985 and July 31th 1989, and were able to obtain the following conclusions. 1) There were 14(4.5%) bilateral breast cancers among the 311 confirmed breast cancers. 2) Among the bilateral breast cancers, 5(31%) were synchronous and 9(69%) metachronous. 3) Average interval between the first and the second breast cancer in metachronous cancers was 3.8 year(1-15 years). 4) Bilateral breast cancer was most prevalent in the fifth decade (6/14) with the mean age of 47 years. 5) Film mammogram and sonomammogram showed findings of typical breast malignancies. There was no additional specific findings for each cancer in bilateral breast cancers which was different from unilateral cancers. Therefor, in the patients with unilateral breast cancer, possibility of the second lesion in the contralateral side must be considered and a close follow up observation should be done for at least 3 years

  5. A SECOND CASE OF BILATERAL RHEGMATOGENOUS RETINAL DETACHMENTS REPAIRED WITH SIMULTANEOUS BILATERAL PNEUMATIC RETINOPEXY.

    Science.gov (United States)

    Rubin, Uriel; De Jager, Cornelis; Zakour, Moayed; Gonder, J Thomas

    2017-01-01

    To present a case of a patient with simultaneous bilateral retinal detachments treated successfully with bilateral pneumatic retinopexy. Case report. This is a case of an otherwise healthy 49-year-old woman with no remarkable ocular history that presented with simultaneous phakic superior bilateral rhegmatogenous retinal detachments. Treatment on the day of presentation included laser retinopexy of the inferior lattice degeneration in the left eye and bilateral intravitreal injection of 0.4 cc of 100% C3F8 gas preceded by topical anesthesia. After 48 hours, both retinas were completely reattached, and bilateral laser retinopexy was performed to the superior tears. After a review of the literature, the authors could find only two reported cases of simultaneous bilateral retinal detachments treated successfully with pneumatic retinopexy. This is not only a cost-effective procedure but also allows treatment when there is no immediate operating room availability or a when a quick referral for surgery is not possible.

  6. A comparison of hair colour measurement by digital image analysis with reflective spectrophotometry.

    Science.gov (United States)

    Vaughn, Michelle R; van Oorschot, Roland A H; Baindur-Hudson, Swati

    2009-01-10

    While reflective spectrophotometry is an established method for measuring macroscopic hair colour, it can be cumbersome to use on a large number of individuals and not all reflective spectrophotometry instruments are easily portable. This study investigates the use of digital photographs to measure hair colour and compares its use to reflective spectrophotometry. An understanding of the accuracy of colour determination by these methods is of relevance when undertaking specific investigations, such as those on the genetics of hair colour. Measurements of hair colour may also be of assistance in cases where a photograph is the only evidence of hair colour available (e.g. surveillance). Using the CIE L(*)a(*)b(*) colour space, the hair colour of 134 individuals of European ancestry was measured by both reflective spectrophotometry and by digital image analysis (in V++). A moderate correlation was found along all three colour axes, with Pearson correlation coefficients of 0.625, 0.593 and 0.513 for L(*), a(*) and b(*) respectively (p-values=0.000), with means being significantly overestimated by digital image analysis for all three colour components (by an average of 33.42, 3.38 and 8.00 for L(*), a(*) and b(*) respectively). When using digital image data to group individuals into clusters previously determined by reflective spectrophotometric analysis using a discriminant analysis, individuals were classified into the correct clusters 85.8% of the time when there were two clusters. The percentage of cases correctly classified decreases as the number of clusters increases. It is concluded that, although more convenient, hair colour measurement from digital images has limited use in situations requiring accurate and consistent measurements.

  7. Experimental testing of the digital multichannel analyzer for gamma spectrometry measurements

    International Nuclear Information System (INIS)

    Novkovic, D.; Nadjdjerdj, L.; Kandic, A.; Vukanac, I.; Djurasevic, M.

    2008-01-01

    The results of experimental testing of the digital multichannel analyzer which digitalizes the signal after a preamplifier are presented. The recordings of some of the characteristics of the spectrometer containing a digital MCA, such as full-peak efficiency, net-area ratio of the two peaks and the stability of the peak position, were carried out under different input counting rates, with different radioactive sources. The tested MCA has shown some excellent features, like the stability of the peak position over a long-term period and flexibility in the adjusting of optimum measurement conditions. However, the performed tests have also shown some serious and unexpected disadvantages of the digital MCA when it operates under certain circumstances, one of them having to do with the automatic tuning of live-time correction at low-input counting rates. (author)

  8. Bilateral experimental neck pain reorganize axioscapular muscle coordination and pain sensitivity.

    Science.gov (United States)

    Christensen, S W; Hirata, R P; Graven-Nielsen, T

    2017-04-01

    Neck pain is a large clinical problem where reorganized trunk and axioscapular muscle activities have been hypothesised contributing to pain persistence and pain hypersensitivity. This study investigated the effects of bilateral experimental neck pain on trunk and axioscapular muscle function and pain sensitivity. In 25 healthy volunteers, bilateral experimental neck pain was induced in the splenius capitis muscles by hypertonic saline injections. Isotonic saline was used as control. In sitting, subjects performed slow, fast and slow-resisted unilateral arm movements before, during and after injections. Electromyography (EMG) was recorded from eight shoulder and trunk muscles bilaterally. Pressure pain thresholds (PPTs) were assessed bilaterally at the neck, head and arm. Data were normalized to the before-measures. Compared with control and post measurements, experimental neck pain caused (1) decreased EMG activity of the ipsilateral upper trapezius muscles during all but slow-resisted down movements (p neck pain reorganized axioscapular and trunk muscle activity together with local hyperalgesia and widespread hypoalgesia indicating that acute neck pain immediately affects trunk and axioscapular function which may affect both assessment and treatment. Bilateral clinical neck pain alters axioscapular muscle coordination but only effects of unilateral experimental neck pain has been investigated. Bilateral experimental neck pain causes task-dependent reorganized axioscapular and trunk muscle activity in addition to widespread decrease in pressure pain sensitivity. © 2016 European Pain Federation - EFIC®.

  9. Measurement of Piezoelectric Transformer Vibrations by Digital Holography

    Czech Academy of Sciences Publication Activity Database

    Psota, Pavel; Lédl, Vít; Doleček, Roman; Erhart, J.; Kopecký, V.

    2014-01-01

    Roč. 59, č. 9 (2014), s. 1962-1968 ISSN 0885-3010 R&D Projects: GA MŠk(CZ) ED2.1.00/03.0079 Institutional support: RVO:61389021 Keywords : digital holographic * ime-averaged holographic * small amplitude * vibrations amplitude measurement * piezoelectric transformer s Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 1.512, year: 2014

  10. A digital instrument for reactivity measurements in a nuclear reactor

    International Nuclear Information System (INIS)

    Chwaszczewski, S.

    1979-01-01

    An instrument for digital determination of the reactivity in nuclear reactors is described. It is based on the CAMAC standard apparatus, suitable for the use of pulse or current type neutron detectors and operates with prompt response and an output signal proportional to the core neutron flux. The measured data of neutron flux and reactivity can be registered by a digital display unit, an indicator, or, by request of the operator, a paper type punch. The algorithms used for reactivity calculation are considered and the results of numerical studies on those algorithms are discussed. The instrument has been used for determining the reactivity of the control elements in the fast-thermal assembly ANNA and in the research reactor MARIA. Some results of these measurements are given. (author)

  11. Measurement of width and step-height of photolithographic product patterns by using digital holography

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Ju Yeop; Kang, Sung Hoon; Ma, Hye Joon; Jung, Hyun Chul; Hong, Chung Ki; Kim, Kyeong Suk [Chosun University, Gwangju (Korea, Republic of); Kwon, Ik Hwan [Dept. of Physics, Pohang University of Science and Technology, Pohang (Korea, Republic of); Yang, Seung Pil [Dept. of Ophthalmic Optics, Dong A College of Health, Youngam (Korea, Republic of)

    2016-02-15

    The semiconductor industry is one of the key industries of Korea, which has continued growing at a steady annual growth rate. Important technology for the semiconductor industry is high integration of devices. This is to increase the memory capacity for unit area, of which key is photolithography. The photolithography refers to a technique for printing the shadow of light lit on the mask surface on to wafer, which is the most important process in a semiconductor manufacturing process. In this study, the width and step-height of wafers patterned through this process were measured to ensure uniformity. The widths and inter-plate heights of the specimens patterned using photolithography were measured using transmissive digital holography. A transmissive digital holographic interferometer was configured, and nine arbitrary points were set on the specimens as measured points. The measurement of each point was compared with the measurements performed using a commercial device called scanning electron microscope (SEM) and Alpha Step. Transmission digital holography requires a short measurement time, which is an advantage compared to other techniques. Furthermore, it uses magnification lenses, allowing the flexibility of changing between high and low magnifications. The test results confirmed that transmissive digital holography is a useful technique for measuring patterns printed using photolithography.

  12. Measurement of width and step-height of photolithographic product patterns by using digital holography

    International Nuclear Information System (INIS)

    Shin, Ju Yeop; Kang, Sung Hoon; Ma, Hye Joon; Jung, Hyun Chul; Hong, Chung Ki; Kim, Kyeong Suk; Kwon, Ik Hwan; Yang, Seung Pil

    2016-01-01

    The semiconductor industry is one of the key industries of Korea, which has continued growing at a steady annual growth rate. Important technology for the semiconductor industry is high integration of devices. This is to increase the memory capacity for unit area, of which key is photolithography. The photolithography refers to a technique for printing the shadow of light lit on the mask surface on to wafer, which is the most important process in a semiconductor manufacturing process. In this study, the width and step-height of wafers patterned through this process were measured to ensure uniformity. The widths and inter-plate heights of the specimens patterned using photolithography were measured using transmissive digital holography. A transmissive digital holographic interferometer was configured, and nine arbitrary points were set on the specimens as measured points. The measurement of each point was compared with the measurements performed using a commercial device called scanning electron microscope (SEM) and Alpha Step. Transmission digital holography requires a short measurement time, which is an advantage compared to other techniques. Furthermore, it uses magnification lenses, allowing the flexibility of changing between high and low magnifications. The test results confirmed that transmissive digital holography is a useful technique for measuring patterns printed using photolithography

  13. Introduction of a Case of Bilateral Pheochromocytoma Tumor

    Directory of Open Access Journals (Sweden)

    M Zare

    2009-01-01

    Full Text Available Summary: Pheochromocytoma is an adrenal tumor characterized by symptoms of hypertension, headache, increased sweating, and tachycardia .In one third of patients, the tumor is discovered incidentally during radiological evaluation of the abdomen. In this article a case of bilateral pheochromocytoma is reported. The patient, a twelve years old boy, referred with complaints of headache, flushing, palpitation and blurring of vision. He had a blood pressure of 200/120 mmHg and after investigation, coarctation of aorta was excluded. On abdominal ultrasound, bilateral adrenal mass was diagnosed, followed by serial measurements of urinary vanillyl mandellic acid (VMA which was found to be elevated. Meta- Iodio benzyl glunidin (MIBG scan showed increased uptake in both adrenals. Patient underwent laparotomy and bilateral adrenalectomy with the diagnosis of pheochromocytoma. Pathologic report confirmed the diagnosis

  14. Parasternal lymphoscintigraphy using the bilateral collimator

    International Nuclear Information System (INIS)

    Ohtake, Eiji; Iio, Masahiro; Toyama, Hinako; Kawaguchi, Shinichiro; Murata, Hajime

    1981-01-01

    A new method for measuring the depth of the parasternal lymph node was studied. The bilateral collimator used in this study consisted of two arrays of parallel holes which were slanted at +-30 degrees, respectively, to the vertical line. When the collimator was set to image the object in both sides of the field, the object and the dual images formed a regular triangle. The distance (D) from the image (crystal) plane to the object can be expressed by the equation: D = 1/2.L.cot30 0 = 0.866.L where L is the interval between the dual images calibrated to the real length. The distance from the collimator surface to the object is obtained by subtracting the effective thickness (T) between the image plane and the collimator surface from D. T was experimentally measured by the above equation, placing point sources on the collimator surface. The principle was applied to measure the depth of the parasternal lymph node. The parasternal lymphoscintigram was obtained four hours after bilateral subcostal injection of sup(99m)Tc-sulfur colloid and the image was taken by a Searle Pho/Gamma LFOV camera equipped with the bilateral collimator. When the scintigraphic image was made, radioactive markers were placed at the body surface to measure the distance from the collimator surface to the body surface Nineteen patients were examined. As a result, the lymph nodes were found to be located in the depths ranging widely from 0.4 to 6.5 cm from the anterior surface of the chest wall. These lymph nodes were thought to contain the deeply seated mediastinal nodes, and the superficial nodes located directly beneath the skin. Model studies were also performed to estimate the accuracy of this method and satisfactory results were obtained. (author)

  15. Questioning short-term memory and its measurement: Why digit span measures long-term associative learning.

    Science.gov (United States)

    Jones, Gary; Macken, Bill

    2015-11-01

    Traditional accounts of verbal short-term memory explain differences in performance for different types of verbal material by reference to inherent characteristics of the verbal items making up memory sequences. The role of previous experience with sequences of different types is ostensibly controlled for either by deliberate exclusion or by presenting multiple trials constructed from different random permutations. We cast doubt on this general approach in a detailed analysis of the basis for the robust finding that short-term memory for digit sequences is superior to that for other sequences of verbal material. Specifically, we show across four experiments that this advantage is not due to inherent characteristics of digits as verbal items, nor are individual digits within sequences better remembered than other types of individual verbal items. Rather, the advantage for digit sequences stems from the increased frequency, compared to other verbal material, with which digits appear in random sequences in natural language, and furthermore, relatively frequent digit sequences support better short-term serial recall than less frequent ones. We also provide corpus-based computational support for the argument that performance in a short-term memory setting is a function of basic associative learning processes operating on the linguistic experience of the rememberer. The experimental and computational results raise questions not only about the role played by measurement of digit span in cognition generally, but also about the way in which long-term memory processes impact on short-term memory functioning. Copyright © 2015 The Authors. Published by Elsevier B.V. All rights reserved.

  16. High-speed digital holographic interferometry for vibration measurement

    International Nuclear Information System (INIS)

    Pedrini, Giancarlo; Osten, Wolfgang; Gusev, Mikhail E.

    2006-01-01

    A system based on digital holographic interferometry for the measurement of vibrations is presented. A high-power continuous laser(10 W) and a high-speed CCD camera are used. Hundreds of holograms of an object that has been subjected to dynamic deformation are recorded. The acquisition speed and the time of exposure of the detector are determined by the vibration frequency. Two methods are presented for triggering the camera in order to acquire at a given phase of the vibration. The phase of the wavefront is calculated from the recorded holograms by use of a two-dimensional digital Fourier-transform method. The deformation of the object is obtained from the phase. By combination of the deformations recorded at different times it is possible to reconstruct the vibration of the object

  17. Measurement of Three-Dimensional Deformations by Phase-Shifting Digital Holographic Interferometry

    Directory of Open Access Journals (Sweden)

    Percival Almoro

    2003-06-01

    Full Text Available Out-of-plane deformations of a cantilever were measured using phase-shifting digital holographicinterferometry (PSDHI and the Fourier transform method (FTM. The cantilever was recorded in twodifferent states, and holograms were stored electronically with a charge-coupled device (CCD camera.When the holograms are superimposed and reconstructed jointly, a holographic interferogram results.The three-dimensional (3D surface deformations were successfully visualized by applying FTM toholographic interferogram analysis. The minimum surface displacement measured was 0.317 µm. Theprocessing time for the digital reconstruction and visualization of 3D deformation took about 1 minute.The technique was calibrated using Michelson interferometry setup.

  18. Bilateral acute retinal necrosis associated with bilateral uveal effusion in an immunocompetent patient: A challenging association

    Directory of Open Access Journals (Sweden)

    S Bala Murugan

    2018-01-01

    Full Text Available Bilateral uveal effusion syndrome associated with bilateral acute retinal necrosis is a diagnostic and therapeutic challenge. A 52 year old man presented with bilateral angle closure with choroidal detachment. With restricted fundus view, parenteral steroid was started. During close follow up bilateral discrete areas of peripheral retinitis were noted. Parenteral steroids were promptly stopped and parenteral antivirals with oral steroids were continued. It showed healing response with nil recurrences till last follow up. Aggressive treatment of bilateral uveal effusion with parenteral steroids can cause progression of bilateral acute retinal necrosis leading to phthisis bulbi. However early diagnosis, prompt intervention and close follow up are the key elements to therapeutic success even during diagnostic surprises and avoid costly mistakes.

  19. 38 CFR 4.26 - Bilateral factor.

    Science.gov (United States)

    2010-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 1 2010-07-01 2010-07-01 false Bilateral factor. 4.26... DISABILITIES General Policy in Rating § 4.26 Bilateral factor. When a partial disability results from disease... disability. The bilateral factor will be applied to such bilateral disabilities before other combinations are...

  20. Research on Damage Identification of Bridge Based on Digital Image Measurement

    Science.gov (United States)

    Liang, Yingjing; Huan, Shi; Tao, Weijun

    2017-12-01

    In recent years, the number of the damage bridge due to excessive deformation gradually increased, which caused significant property damage and casualties. Hence health monitoring and the damage detection of the bridge structure based on the deflection measurement are particularly important. The current conventional deflection measurement methods, such as total station, connected pipe, GPS, etc., have many shortcomings as low efficiency, heavy workload, low degree of automation, operating frequency and working time constrained. GPS has a low accuracy in the vertical displacement measurement and cannot meet the dynamic measured requirements of the current bridge engineering. This paper presents a bridge health monitoring and damage detection technology based on digital image measurement method in which the measurement accuracy is sub-millimeter level and can achieve the 24-hour automatic non-destructive monitoring for the deflection. It can be concluded from this paper that it is feasible to use digital image measurement method for identification of the damage in the bridge structure, because it has been validated by the theoretical analysis, the laboratory model and the application of the real bridge.

  1. Time-Varying Distortions of Binaural Information by Bilateral Hearing Aids

    Science.gov (United States)

    Rodriguez, Francisco A.; Portnuff, Cory D. F.; Goupell, Matthew J.; Tollin, Daniel J.

    2016-01-01

    In patients with bilateral hearing loss, the use of two hearing aids (HAs) offers the potential to restore the benefits of binaural hearing, including sound source localization and segregation. However, existing evidence suggests that bilateral HA users’ access to binaural information, namely interaural time and level differences (ITDs and ILDs), can be compromised by device processing. Our objective was to characterize the nature and magnitude of binaural distortions caused by modern digital behind-the-ear HAs using a variety of stimuli and HA program settings. Of particular interest was a common frequency-lowering algorithm known as nonlinear frequency compression, which has not previously been assessed for its effects on binaural information. A binaural beamforming algorithm was also assessed. Wide dynamic range compression was enabled in all programs. HAs were placed on a binaural manikin, and stimuli were presented from an arc of loudspeakers inside an anechoic chamber. Stimuli were broadband noise bursts, 10-Hz sinusoidally amplitude-modulated noise bursts, or consonant–vowel–consonant speech tokens. Binaural information was analyzed in terms of ITDs, ILDs, and interaural coherence, both for whole stimuli and in a time-varying sense (i.e., within a running temporal window) across four different frequency bands (1, 2, 4, and 6 kHz). Key findings were: (a) Nonlinear frequency compression caused distortions of high-frequency envelope ITDs and significantly reduced interaural coherence. (b) For modulated stimuli, all programs caused time-varying distortion of ILDs. (c) HAs altered the relationship between ITDs and ILDs, introducing large ITD–ILD conflicts in some cases. Potential perceptual consequences of measured distortions are discussed. PMID:27698258

  2. Clinical trial comparing autogenous fascia lata sling and Gore-Tex suspension in bilateral congenital ptosis

    Directory of Open Access Journals (Sweden)

    Elsamkary MA

    2016-03-01

    Full Text Available Mahmoud Ahmed Elsamkary,1 Maged Maher Salib Roshdy1,2 1Ophthalmology Department, Faculty of Medicine, Ain Shams University, Cairo, Egypt; 2Pediatric Ophthalmology Department, Al Watany Eye Hospital, Cairo, Egypt Purpose: To study the effect of autogenous fascia lata sling (AFLS versus Gore-Tex suspension (GTS regarding the functional and aesthetic outcomes in patients with bilateral congenital ptosis. Patients and methods: A prospective comparative randomized single-center study enrolled 110 patients with bilateral congenital ptosis. One group (n=55 underwent AFLS and the second group (n=55 underwent GTS. Exclusion criteria were good levator function, absent Bell’s phenomenon, and abnormal ocular motility. Follow-up period was 2 years. Functional outcome was measured from digital photos by analysis of upper eyelid margin position relative to the superior limbus and classified as very good (<3 mm, good (3–5 mm, poor (>5 mm, and recurrent. Aesthetic outcome was assessed in terms of lid contour, symmetry of eyelid height, and lid crease presence. Complications were also reported. Results: Failure rate (recurrence and complications was less in AFLS (P=0.035. Symmetrical lid height and good contour were more frequently attained by AFLS (P=0.007 and 0.047, respectively. However, the frequency of very good, good, poor, recurrence, lagopthalmos, ectropion, infection, and formed lid crease individually showed no statistically significant difference (P=0.252, 0.482, 1, 0.489, 0.438, 1, 0.618, and 0.506, respectively. Conclusion: AFLS is a better choice in surgery for patients with bilateral congenital ptosis because it has fewer complications and a lesser recurrence rate than GTS. Keywords: ptosis surgery, surgical outcomes, ptosis recurrence, lagophthalmos

  3. Analysis of the Measurement and Modeling of a Digital Inverter Based on a Ferroelectric Transistor

    Science.gov (United States)

    MacLeod, Todd C.; Phillips, Thomas A.; Sayyah, Rana; Ho, Fat D.

    2009-01-01

    The use of ferroelectric materials for digital memory devices is widely researched and implemented, but ferroelectric devices also possess unique characteristics that make them have interesting and useful properties in digital circuits. Because ferroelectric transistors possess the properties of hysteresis and nonlinearity, a digital inverter containing a FeFET has very different characteristics than one with a traditional FET. This paper characterizes the properties of the measurement and modeling of a FeFET based digital inverter. The circuit was set up using discrete FeFETs. The purpose of this circuit was not to produce a practical integrated circuit that could be inserted directly into existing digital circuits, but to explore the properties and characteristics of such a device and to look at possible future uses. Input and output characteristics are presented, as well as timing measurements. Comparisons are made between the ferroelectric device and the properties of a standard digital inverter. Potential benefits and possible uses of such a device are presented.

  4. Persian randomized dichotic digits test: Development and dichotic listening performance in young adults

    Directory of Open Access Journals (Sweden)

    Mohammad Ebrahim Mahdavi

    2015-02-01

    Full Text Available Background and Aims: The dichotic listening subtest is an important component of the test battery for auditory processing assessment in both children and adults. A randomized dichotic digits test (RDDT was created to compensate for sensitivity weakness of double digits when detecting abnormal ear asymmetry during dichotic listening. The aim of this study was the development and  intial evaluation of the Persian randomized dichotic digits test.Method: Persian digits 1-10 (except for the bisyllabic digit, 4 uttered by a native Persian language speaker were recorded in a studio. After alignment of intensity and temporal characteristics of digit waveforms, lists 1 and 2 of the RDDT were reproduced. List 1 of the test was administered at 55 dBHL on 50 right-handed normal hearing individuals (with an equal sex ratio in the age group of 18-25 years and hearing thresholds of 15 dBHL or better in audiometric frequencies.Results: Mean (standard deviation of percent-correct score for right and left ears and right ear advantage of the subjects was 94.3 (5.3, 84.8 (7.7, and 9.5 (7.0 percent, respectively. Sixty percent of the subjects showed normal results and unilateral and bilateral deficits were seen in 24 percent and 16 percent, respectively, of studied individuals.Conclusion: It seems the Persian version of RDDT test is the same as the original test as it is able to test ear asymmerty, unilateral and bilateral deficits in dichotic listening.

  5. Pregnancy following bilateral salpingectomy

    DEFF Research Database (Denmark)

    Oturai, Annette Bang

    2008-01-01

    This report presents a rare case of spontaneous pregnancy following bilateral salpingectomy. A woman with a history of bilateral salpingectomy was admitted to hospital because of abdominal pain and positive urine HCG. Surprisingly, ultrasound confirmed a live intrauterine fetus. The pregnancy...... was unwanted, and the woman decided to terminate the pregnancy. She was offered diagnostic examination to localise a potential fistula, but she declined. In a MEDLINE search of English literature this is only the second case of spontaneous pregnancy following bilateral salpingectomy Udgivelsesdato: 2008/4/21...

  6. Development of reconfigurable analog and digital circuits for plasma diagnostics measurement systems

    International Nuclear Information System (INIS)

    Srivastava, Amit Kumar; Sharma, Atish; Raval, Tushar

    2009-01-01

    In long pulse discharge tokamak, a large number of diagnostic channels are being used to understand the complex behavior of plasma. Different diagnostics demand different types of analog and digital processing for plasma parameters measurement. This leads to variable requirements of signal processing for diagnostic measurement. For such types of requirements, we have developed hardware with reconfigurable electronic devices, which provide flexible solution for rapid development of measurement system. Here the analog processing is achieved by Field Programmable Analog Array (FPAA) integrated circuit while reconfigurable digital devices (CPLD/FPGA) achieve digital processing. FPAA's provide an ideal integrated platform for implementing low to medium complexity analog signal processing. With dynamic reconfigurability, the functionality of the FPAA can be reconfigured in-system by the designer or on the fly by a microprocessor. This feature is quite useful to manipulate the tuning or the construction of any part of the analog circuit without interrupting operation of the FPAA, thus maintaining system integrity. The hardware operation control logic circuits are configured in the reconfigurable digital devices (CPLD/FPGA) to control proper hardware functioning. These reconfigurable devices provide the design flexibility and save the component space on the board. It also provides the flexibility for various setting through software. The circuit controlling commands are either issued by computer/processor or generated by circuit itself. (author)

  7. Evaluating digital libraries in the health sector. Part 1: measuring inputs and outputs.

    Science.gov (United States)

    Cullen, Rowena

    2003-12-01

    This is the first part of a two-part paper which explores methods that can be used to evaluate digital libraries in the health sector. In this first part, some approaches to evaluation that have been proposed for mainstream digital information services are examined for their suitability to provide models for the health sector. The paper summarizes some major national and collaborative initiatives to develop measures for digital libraries, and analyses these approaches in terms of their relationship to traditional measures of library performance, which are focused on inputs and outputs, and their relevance to current debates among health information specialists. The second part* looks more specifically at evaluative models based on outcomes, and models being developed in the health sector.

  8. Measuring and Bridging the Gender Digital Divide in Rural Pakistan ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Measuring and Bridging the Gender Digital Divide in Rural Pakistan ... to critically examining the gender-specific aspects of ICT use and its impact on development in ... In partnership with UNESCO's Organization for Women in Science for the ...

  9. Comparison of root canal lathing measurement by conventional and digital radiology

    International Nuclear Information System (INIS)

    Mitrova, N.; Slavik, J.; Cecetkova, A.; Jenca, A.; Hanusinova, V.; Ondrasovicova, J.

    2006-01-01

    A correct working length is a critical factor within the endodontic treatment. The length of the root canal can be measured by different methods. The aim of this study was to compare methods used for measuring the length of root canals using conventional and digital radiology. The measurement was provided in both - in vitro and in vivo conditions. (authors)

  10. Bilateral persistent hyperplastic primary vitreous

    Directory of Open Access Journals (Sweden)

    Jain Tarun

    2009-01-01

    Full Text Available A case of bilateral persistent hyperplastic primary vitreous (PHPV in a 3-month-old male infant, who had bilateral leukokoria, is presented. The child was referred for imaging with a clinical suspicion of retinoblastoma. Gray-scale ultrasound evaluation revealed an echogenic band in the posterior segment of both globes, extending from the posterior surface of the lens capsule to the optic disc. Doppler examination revealed the presence of arterial flow in the band in both globes. Associated echogenic hemorrhage was also seen, which was confirmed by computed tomography. Most cases of PHPV are sporadic and unilateral, and bilateral PHPV is rare. The imaging features in this case suggest the diagnosis of bilateral PHPV and differentiate it from retinoblastoma. This entity, although infrequent, should be considered in the differential diagnosis while evaluating bilateral leukokoria.

  11. The Accuracy and Reproducibility of Linear Measurements Made on CBCT-derived Digital Models.

    Science.gov (United States)

    Maroua, Ahmad L; Ajaj, Mowaffak; Hajeer, Mohammad Y

    2016-04-01

    To evaluate the accuracy and reproducibility of linear measurements made on cone-beam computed tomography (CBCT)-derived digital models. A total of 25 patients (44% female, 18.7 ± 4 years) who had CBCT images for diagnostic purposes were included. Plaster models were obtained and digital models were extracted from CBCT scans. Seven linear measurements from predetermined landmarks were measured and analyzed on plaster models and the corresponding digital models. The measurements included arch length and width at different sites. Paired t test and Bland-Altman analysis were used to evaluate the accuracy of measurements on digital models compared to the plaster models. Also, intraclass correlation coefficients (ICCs) were used to evaluate the reproducibility of the measurements in order to assess the intraobserver reliability. The statistical analysis showed significant differences on 5 out of 14 variables, and the mean differences ranged from -0.48 to 0.51 mm. The Bland-Altman analysis revealed that the mean difference between variables was (0.14 ± 0.56) and (0.05 ± 0.96) mm and limits of agreement between the two methods ranged from -1.2 to 0.96 and from -1.8 to 1.9 mm in the maxilla and the mandible, respectively. The intraobserver reliability values were determined for all 14 variables of two types of models separately. The mean ICC value for the plaster models was 0.984 (0.924-0.999), while it was 0.946 for the CBCT models (range from 0.850 to 0.985). Linear measurements obtained from the CBCT-derived models appeared to have a high level of accuracy and reproducibility.

  12. Accuracy of a digital weight scale relative to the nintendo wii in measuring limb load asymmetry.

    Science.gov (United States)

    Kumar, Ns Senthil; Omar, Baharudin; Joseph, Leonard H; Hamdan, Nor; Htwe, Ohnmar; Hamidun, Nursalbiyah

    2014-08-01

    [Purpose] The aim of the present study was to investigate the accuracy of a digital weight scale relative to the Wii in limb loading measurement during static standing. [Methods] This was a cross-sectional study conducted at a public university teaching hospital. The sample consisted of 24 participants (12 with osteoarthritis and 12 healthy) recruited through convenient sampling. Limb loading measurements were obtained using a digital weight scale and the Nintendo Wii in static standing with three trials under an eyes-open condition. The limb load asymmetry was computed as the symmetry index. [Results] The accuracy of measurement with the digital weight scale relative to the Nintendo Wii was analyzed using the receiver operating characteristic (ROC) curve and Kolmogorov-Smirnov test (K-S test). The area under the ROC curve was found to be 0.67. Logistic regression confirmed the validity of digital weight scale relative to the Nintendo Wii. The D statistics value from the K-S test was found to be 0.16, which confirmed that there was no significant difference in measurement between the equipment. [Conclusion] The digital weight scale is an accurate tool for measuring limb load asymmetry. The low price, easy availability, and maneuverability make it a good potential tool in clinical settings for measuring limb load asymmetry.

  13. Idiopathic bilateral male breast abscess.

    Science.gov (United States)

    Sinha, Rajan Kumar; Sinha, Mithilesh Kumar; Gaurav, Kumar; Kumar, Amar

    2014-03-10

    A 38-year-old man presented with bilateral breast swelling, along with pain and redness for 7 days. Bilateral axillary nodes were also palpable; which were multiple and discrete. A provisional diagnosis of bilateral breast abscess was made with suspicion of underlying malignancy. Incision and drainage through subareolar incision was performed and the adjoining tissue was excised and sent for histopathological examination.

  14. Measurement of in-plane strain with dual beam spatial phase-shift digital shearography

    International Nuclear Information System (INIS)

    Xie, Xin; Chen, Xu; Li, Junrui; Yang, Lianxiang; Wang, Yonghong

    2015-01-01

    Full-field in-plane strain measurement under dynamic loading by digital shearography remains a big challenge in practice. A phase measurement for in-plane strain information within one time frame has to be achieved to solve this problem. This paper presents a dual beam spatial phase-shift digital shearography system with the capacity to measure phase distribution corresponding to in-plane strain information within a single time frame. Two laser beams with different wavelengths are symmetrically arranged to illuminate the object under test, and two cameras with corresponding filters, which enable simultaneous recording of two shearograms, are utilized for data acquisition. The phase information from the recorded shearograms, which corresponds to the in-plane strain, is evaluated by the spatial phase-shift method. The spatial phase-shift shearography system realizes a measurement of the in-plane strain through the introduction of the spatial phase-shift technique, using one frame after the loading and one frame before loading. This paper presents the theory of the spatial phase-shift digital shearography for in-plane strain measurement and its derivation, experimental results, and the technique’s potential. (paper)

  15. Bilateral inguinal hernia repair: laparoscopic or open approach?

    Science.gov (United States)

    Feliu, X; Clavería, R; Besora, P; Camps, J; Fernández-Sallent, E; Viñas, X; Abad, J M

    2011-02-01

    The aim of this study was to investigate outcomes in the treatment of bilateral inguinal hernia, comparing the laparoscopic totally extraperitoneal (TEP) and open tension-free mesh repair (LICHT) approaches. We performed a prospective controlled non randomized clinical study in 128 patients with bilateral inguinal hernia over a period of 3 years. LICHT was used in 106 cases (53 patients) while TEP was employed in 150 cases (75 patients). The main outcome measurements were: recurrence rate, operating time, hospital stay and postoperative complications. There were three recurrences (2.3%): two in the LICHT group (3.8%) and one (1.3%) in the TEP group P = NS. The TEP procedure was faster than LICHT repair (48.8 ± 10.8 vs. 70.4 ± 11.2 min) P approach is an effective option for the treatment of bilateral inguinal hernia when performed by experienced surgeons.

  16. Testing digital recursive filtering method for radiation measurement channel using pin diode detector

    International Nuclear Information System (INIS)

    Talpalariu, C. M.; Talpalariu, J.; Popescu, O.; Mocanasu, M.; Lita, I.; Visan, D. A.

    2016-01-01

    In this work we have studied a software filtering method implemented in a pulse counting computerized measuring channel using PIN diode radiation detector. In case our interest was focalized for low rate decay radiation measurement accuracies improvement and response time optimization. During works for digital mathematical algorithm development, we used a hardware radiation measurement channel configuration based on PIN diode BPW34 detector, preamplifier, filter and programmable counter, computer connected. We report measurement results using two digital recursive methods in statically and dynamically field evolution. Software for graphical input/output real time diagram representation was designed and implemented, facilitating performances evaluation between the response of fixed configuration software recursive filter and dynamically adaptive configuration recursive filter. (authors)

  17. Bilateral Diabetic Papillopathy and Metabolic Control

    DEFF Research Database (Denmark)

    Ostri, Christoffer; Lund-Andersen, Henrik; Sander, Birgit

    2010-01-01

    OBJECTIVE: The pathogenesis of diabetic papillopathy largely is unknown, but case reports suggest that it may follow rapidly improved metabolic control. The present study was designed to investigate this hypothesis. DESIGN: Retrospective case-control study. PARTICIPANTS: Two thousand sixty......-six patients with type 1 diabetes. METHODS: Review of clinical, photographic, and clinical chemistry records from a large diabetology and ophthalmology unit between 2001 and 2008. MAIN OUTCOME MEASURES: Simultaneous, bilateral diabetic papillopathy. RESULTS: The mean follow-up was 4.9 years. During 10 020...... patient-years of observation, bilateral diabetic papillopathy developed in 5 patients. During the year preceding this incident, all 5 patients had experienced a decrease in glycosylated hemoglobin A(1c) (HbA(1C)) at a maximum rate of -2.5 (mean) percentage points per quarter year, which was significantly...

  18. Safety assessment of inter-channel / inter-system digital communications: A defensive measures approach

    International Nuclear Information System (INIS)

    Thuy, N. N. Q.

    2006-01-01

    Inappropriately designed inter-channel and inter-system digital communications could initiate common cause failure of multiple channels or multiple systems. Defensive measures were introduced in EPRI report TR-1002835 (Guideline for Performing Defense-in-Depth and Diversity Assessments for Digital Upgrades) to assess, on a deterministic basis, the susceptibility of digital systems architectures to common-cause failures. This paper suggests how this approach could be applied to assess inter-channel and inter-system digital communications from a safety standpoint. The first step of the approach is to systematically identify the so called 'influence factors' that one end of the data communication path can have on the other. Potential factors to be considered would typically include data values, data volumes and data rates. The second step of the approach is to characterize the ways possible failures of a given end of the communication path could affect these influence factors (e.g., incorrect data values, excessive data rates, time-outs, incorrect data volumes). The third step is to analyze the designed-in measures taken to guarantee independence of the other end. In addition to classical error detection and correction codes, typical defensive measures are one-way data communication, fixed-rate data communication, fixed-volume data communication, validation of data values. (authors)

  19. Continuous measurement of digital game experiences

    NARCIS (Netherlands)

    Poels, K.; Hoogen, van den W.M.; IJsselsteijn, W.A.; Kort, de Y.A.W.

    2008-01-01

    In recent years, the game industry has developed a wide array of games and gaming devices, targeted to different age and gender groups and to gamers with various play styles. As such, playing digital games has become a highly popular leisure activity. Over recent years, academic research on digital

  20. Digital Lengthening to Treat Finger Deficiency: An Experience of 201 Digits in 104 Patients.

    Science.gov (United States)

    Ding, Zhenyu; Zhu, Xiaozhong; Fu, Kai; Zheng, Xianyou

    2017-01-01

    Objectives. We evaluated the results of digital lengthening by distraction and second-stage bone graft. Methods. We treated finger deficiency of 201 digits in 104 patients (68 males, 36 females) by digital distraction and second-stage bone graft. The distraction was performed with a rate of 1 mm/day (for the first ten days) and 0.5 mm/day followed by using a self-designed bilateral tubal-helical external fixator. The mean follow-up period was 42 months (range 6 to 60 months). Results. The mean lengthening was 29.2 mm (range 25 to 40 mm) and 18.7 mm (range 12 to 32 mm) for metacarpal bones and phalanges, respectively. The mean elongation rate was 174.4% (range 145% to 202%) and 184.8% (range 115% to 283%) for metacarpal bones and phalanges, respectively. The static two-point discriminations and SpO 2 showed no significant differences before and after distraction. Four complications were observed (two skin ruptures and two phalangeal splitting). No pin tract infection or tendon rupture showed. Digital lengthening improved functions of the hand. Conclusion. Digital distraction and second-stage bone graft is an effective method to compensate disabilities caused by lack of finger length. It could be an alternative plan for patients with thumb deficiency instead of toe-to-thumb transplant and patients with finger deficiency instead of ray resection.

  1. Bilateral Endoscopic Medial Maxillectomy for Bilateral Inverted Papilloma

    Directory of Open Access Journals (Sweden)

    Satoru Kodama

    2012-01-01

    Full Text Available Inverted papilloma (IP is a benign tumor of the nasal cavity and paranasal sinuses that is unilateral in most cases. Bilateral IP, involving both sides of the nasal cavity and sinuses, is extremely rare. This paper describes a large IP that filled in both sides of the nasal cavity and sinuses, mimicking association with malignancy. The tumor was successfully treated by bilateral endoscopic medial maxillectomy (EMM. The patient is without evidence of the disease 24 months after surgery. If preoperative diagnosis does not confirm the association with malignancy in IP, endoscopic sinus surgery (ESS should be selected, and ESS, including EMM, is a good first choice of the treatment for IP.

  2. Bilateral Endoscopic Medial Maxillectomy for Bilateral Inverted Papilloma

    Science.gov (United States)

    Kodama, Satoru; Kawano, Toshiaki; Suzuki, Masashi

    2012-01-01

    Inverted papilloma (IP) is a benign tumor of the nasal cavity and paranasal sinuses that is unilateral in most cases. Bilateral IP, involving both sides of the nasal cavity and sinuses, is extremely rare. This paper describes a large IP that filled in both sides of the nasal cavity and sinuses, mimicking association with malignancy. The tumor was successfully treated by bilateral endoscopic medial maxillectomy (EMM). The patient is without evidence of the disease 24 months after surgery. If preoperative diagnosis does not confirm the association with malignancy in IP, endoscopic sinus surgery (ESS) should be selected, and ESS, including EMM, is a good first choice of the treatment for IP. PMID:22953103

  3. Low-cost digital counting interface for fermentation gas measurement

    Energy Technology Data Exchange (ETDEWEB)

    Erdman, M.D.; Deluiche, S.R.

    1985-05-01

    Laboratory- and pilot-scale volumetric measurement of fermentation gas can be readily determined with a standard wet-test gas meter. The initial cost of the meter, however, is quite prohibitive for experimental work and researchers have searched for other means of quantifying gas production. Techniques using calibrated floating gas holders, liquid displacement, flexible membranes, and conventional gas meters have been reported. Many of these methods lack a high degree of accuracy for small gas volumes. Residential gas meters such as those manufactured by Singer company, and others appear well suited for this application as long as a relatively dry gas is passed through the meter and a method is developed to subdivide the meter scale and record the results. The objective of this report was to construct a low cost, accurate, digital counting interface for concurrent operation with a low cost bellows-type gas meter. Although initially constructed for use in gas measurement studies, the interface can be used in other applications where digital output or computer interfacing are desired. 2 references.

  4. Multilateral, regional and bilateral energy trade governance

    Energy Technology Data Exchange (ETDEWEB)

    Leal-Arcas, Rafael; Grasso, Costantino; Rios, Juan Alemany (Queen Mary Univ. of London (United Kingdom))

    2014-12-01

    The current international energy trade governance system is fragmented and multi-layered. Streamlining it for greater legal cohesiveness and international political and economic cooperation would promote global energy security. The current article explores three levels of energy trade governance: multilateral, regional and bilateral. Most energy-rich countries are part of the multilateral trading system, which is institutionalized by the World Trade Organization (WTO). The article analyzes the multilateral energy trade governance system by focusing on the WTO and energy transportation issues. Regionally, the article focuses on five major regional agreements and their energy-related aspects and examines the various causes that explain the proliferation of regional trade agreements, their compatibility with WTO law, and then provides several examples of regional energy trade governance throughout the world. When it comes to bilateral energy trade governance, this article only addresses the European Union’s (EU) bilateral energy trade relations. The article explores ways in which gaps could be filled and overlaps eliminated whilst remaining true to the high-level normative framework, concentrating on those measures that would enhance EU energy security.

  5. Correlation between maximum voluntary contraction and endurance measured by digital palpation and manometry: An observational study

    Directory of Open Access Journals (Sweden)

    Fátima Faní Fitz

    Full Text Available Summary Introduction: Digital palpation and manometry are methods that can provide information regarding maximum voluntary contraction (MVC and endurance of the pelvic floor muscles (PFM, and a strong correlation between these variables can be expected. Objective: To investigate the correlation between MVC and endurance, measured by digital palpation and manometry. Method: Forty-two women, with mean age of 58.1 years (±10.2, and predominant symptoms of stress urinary incontinence (SUI, were included. Examination was firstly conducted by digital palpation and subsequently using a Peritron manometer. MVC was measured using a 0-5 score, based on the Oxford Grading Scale. Endurance was assessed based on the PERFECT scheme. Results: We found a significant positive correlation between the MVC measured by digital palpation and the peak manometric pressure (r=0.579, p<0.001, and between the measurements of the endurance by Peritron manometer and the PERFECT assessment scheme (r=0.559, P<0.001. Conclusion: Our results revealed a positive and significant correlation between the capacity and maintenance of PFM contraction using digital and manometer evaluations in women with predominant symptoms of SUI.

  6. Bilateral, independent juvenile nasopharyngeal angiofibroma

    DEFF Research Database (Denmark)

    Mørkenborg, Marie-Louise; Frendø, M; Stavngaard, T

    2015-01-01

    BACKGROUND: Juvenile nasopharyngeal angiofibroma is a benign, vascular tumour that primarily occurs in adolescent males. Despite its benign nature, aggressive growth patterns can cause potential life-threatening complications. Juvenile nasopharyngeal angiofibroma is normally unilateral, originating...... from the sphenopalatine artery, but bilateral symptoms can occur if a large tumour extends to the contralateral side of the nasopharynx. This paper presents the first reported case of true bilateral extensive juvenile nasopharyngeal angiofibroma involving clinically challenging pre-surgical planning...... embolisation. Radical removal performed as one-step, computer-assisted functional endoscopic sinus surgery was performed. The follow-up period was uncomplicated. CONCLUSION: This case illustrates the importance of suspecting bilateral juvenile nasopharyngeal angiofibroma in patients presenting with bilateral...

  7. Library performance measurement in the digital age

    OpenAIRE

    Conyers, A.; Payne, Philip

    2011-01-01

    Book synopsis: University libraries around the world have embraced the possibilities of the digital learning environment, facilitating its use and proactively seeking to develop the provision of electronic resources and services. The digital environment offers opportunities and challenges for librarians in all aspects of their work - in information literacy, virtual reference, institutional repositories, e-learning, managing digital resources and social media. The authors in this timely book ...

  8. BILATERAL SINGLE SESSION URETEROSCOPY FOR URETERAL ...

    African Journals Online (AJOL)

    Objectives: To determine the feasibility, safety and success rate of bilateral single session rigid retrograde ureteroscopy (URS) for bilateral ureteral calculi. Patients and Methods: Thirty-five patients underwent bilateral single session ureteroscopic calculus removal. Results: Out of 70 renal units in 35 patients treated, ...

  9. Digital pulse processing techniques for high resolution amplitude measurement of radiation detector

    International Nuclear Information System (INIS)

    Singhai, P.; Roy, A.; Dhara, P.; Chatterjee, S.

    2012-01-01

    The digital pulse processing techniques for high resolution amplitude measurement of radiation detector pulse is an effective replacement of expensive and bulky analog processing as the digital domain offers higher channel density and at the same time it is cheaper. We have demonstrated a prototype digital setup with highspeed sampling ADC with sampling frequency of 80-125 MHz followed by series of IIR filters for pulse shaping in a trigger-less acquisition mode. The IIR filters, peak detection algorithm and the data write-out logic was written on VHDL and implemented on FPGA. We used CAMAC as the read out platform. In conjunction with the full hardware implementation we also used a mixed platform with VME digitizer card with raw-sample read out using C code. The rationale behind this mixed platform is to test out various filter algorithms quickly on C and also to benchmark the performance of the chip level ADCs against the standard commercial digitizer in terms of noise or resolution. The paper describes implementation of both the methods with performance obtained in both the methods. (author)

  10. Acute Bilateral Superior Branch Vestibular Neuropathy

    Directory of Open Access Journals (Sweden)

    Dario A. Yacovino

    2018-05-01

    Full Text Available The rapid onset of a bilateral vestibular hypofunction (BVH is often attributed to vestibular ototoxicity. However, without any prior exposure to ototoxins, the idiopathic form of BVH is most common. Although sequential bilateral vestibular neuritis (VN is described as a cause of BVH, clinical evidence for simultaneous and acute onset bilateral VN is unknown. We describe a patient with an acute onset of severe gait ataxia and oscillopsia with features compatible with acute BVH putatively due to a bilateral VN, which we serially evaluated with clinical and laboratory vestibular function testing over the course of 1 year. Initially, bilateral superior and horizontal semicircular canals and bilateral utricles were impaired, consistent with damage to both superior branches of each vestibular nerve. Hearing was spared. Only modest results were obtained following 6 months of vestibular rehabilitation. At a 1-year follow-up, only the utricular function of one side recovered. This case is the first evidence supporting an acute presentation of bilateral VN as a cause for BVH, which would not have been observed without critical assessment of each of the 10 vestibular end organs.

  11. Measurement of clavicular length and shortening after a midshaft clavicular fracture: Spatial digitization versus planar roentgen photogrammetry.

    Science.gov (United States)

    Stegeman, Sylvia A; de Witte, Pieter Bas; Boonstra, Sjoerd; de Groot, Jurriaan H; Nagels, Jochem; Krijnen, Pieta; Schipper, Inger B

    2016-08-01

    Clavicular shortening after fracture is deemed prognostic for clinical outcome and is therefore generally assessed on radiographs. It is used for clinical decision making regarding operative or non-operative treatment in the first 2weeks after trauma, although the reliability and accuracy of the measurements are unclear. This study aimed to assess the reliability of roentgen photogrammetry (2D) of clavicular length and shortening, and to compare these with 3D-spatial digitization measurements, obtained with an electromagnetic recording system (Flock of Birds). Thirty-two participants with a consolidated non-operatively treated two or multi-fragmented dislocated midshaft clavicular fracture were analysed. Two observers measured clavicular lengths and absolute and proportional clavicular shortening on radiographs taken before and after fracture consolidation. The clavicular lengths were also measured with spatial digitization. Inter-observer agreement on the radiographic measurements was assessed using the Intraclass Correlation Coefficient (ICC). Agreement between the radiographic and spatial digitization measurements was assessed using a Bland-Altman plot. The inter-observer agreement on clavicular length, and absolute and proportional shortening on trauma radiographs was almost perfect (ICC>0.90), but moderate for absolute shortening after consolidation (ICC=0.45). The Bland-Altman plot compared measurements of length on AP panorama radiographs with spatial digitization and showed that planar roentgen photogrammetry resulted in up to 37mm longer and 34mm shorter measurements than spatial digitization. Measurements of clavicular length on radiographs are highly reliable between observers, but may not reflect the actual length and shortening of the clavicle when compared to length measurements with spatial digitization. We recommend to use proportional shortening when measuring clavicular length or shortening on radiographs for clinical decision making. Copyright

  12. A model for measurement of noise in CCD digital-video cameras

    International Nuclear Information System (INIS)

    Irie, K; Woodhead, I M; McKinnon, A E; Unsworth, K

    2008-01-01

    This study presents a comprehensive measurement of CCD digital-video camera noise. Knowledge of noise detail within images or video streams allows for the development of more sophisticated algorithms for separating true image content from the noise generated in an image sensor. The robustness and performance of an image-processing algorithm is fundamentally limited by sensor noise. The individual noise sources present in CCD sensors are well understood, but there has been little literature on the development of a complete noise model for CCD digital-video cameras, incorporating the effects of quantization and demosaicing

  13. Three-dimensional motion measurements of free-swimming microorganisms using digital holographic microscopy

    International Nuclear Information System (INIS)

    Lee, Sang Joon; Seo, Kyung Won; Choi, Yong Seok; Sohn, Myong Hwan

    2011-01-01

    A digital holographic microscope is employed to measure the 3D motion of free-swimming microorganisms. The focus function used to quantify image sharpness provides a better depth-directional accuracy with a smaller depth-of-focus compared with the intensity method in determining the depth-directional position of spherical particles of various diameters. The focus function is then applied to measure the 3D positions of free-swimming microorganisms, namely dinoflagellates C. polykrikoides and P. minimum. Both automatic segmentation and proper selection of a focus function for a selected segment are important processes in measuring the positional information of two free-swimming microorganisms of different shapes with various width-to-length ratios. The digital holographic microscopy technique improved in this work is useful for measuring 3D swimming trajectories, velocities and attitudes of hundreds of microorganisms simultaneously. It also exhibits exceptional depth-directional accuracy

  14. Measurement Invariance of the Digital Natives Assessment Scale across Gender in a Sample of Turkish University Students

    Science.gov (United States)

    Ursavas, Ömer Faruk; Kabakçi Yurdakul, Isil; Türk, Mesut; Mcilroy, David

    2016-01-01

    With reference to the digital natives' debate, there is a gap on digital natives' characteristics. To fill this gap, the Digital Natives Assessment Scale was developed to measure students' assessment of the degree to which they perceived themselves to possess the attributes of digital natives. The scale was developed within the Turkish language…

  15. Digit Span as a measure of everyday attention: a study of ecological validity.

    Science.gov (United States)

    Groth-Marnat, Gary; Baker, Sonya

    2003-12-01

    This study investigated the effectiveness of the WAIS-III Digit Span subtest to predict the everyday attention of 75 participants with heterogeneous neurological conditions who were administered the Digit Span subtest as well as the ecologically valid Test of Everyday Attention. In addition, the more visually oriented Picture Completion subtest along with the verbally loaded National Adult Reading Test were administered. Analysis indicated that, although Digit Span was a weak but statistically significant predictor of attentional ability (accounting for 12.7% of the unique variance). Picture Completion was a somewhat stronger predictor (accounting for 19% of the unique variance). The weak association of Digit Span and the Test of Everyday Attention, along with the finding that Picture Completion was a better predictor of performance on the Test of Everyday Attention, question the clinical utility of using Digit Span as a measure of everyday attention.

  16. Refining Measures for Assessing Problematic/Addictive Digital Gaming Use in Clinical and Research Settings.

    Science.gov (United States)

    Faust, Kyle; Faust, David

    2015-08-12

    Problematic or addictive digital gaming (including all types of electronic devices) can and has had extremely adverse impacts on the lives of many individuals across the world. The understanding of this phenomenon, and the effectiveness of treatment design and monitoring, can be improved considerably by continuing refinement of assessment tools. The present article briefly overviews tools designed to measure problematic or addictive use of digital gaming, the vast majority of which are founded on the Diagnostic and Statistical Manual of Mental Disorders (DSM) criteria for other addictive disorders, such as pathological gambling. Although adapting DSM content and strategies for measuring problematic digital gaming has proven valuable, there are some potential issues with this approach. We discuss the strengths and limitations of current methods for measuring problematic or addictive gaming and provide various recommendations that might help in enhancing or supplementing existing tools, or in developing new and even more effective tools.

  17. Accurate and cost-effective MTF measurement system for lens modules of digital cameras

    Science.gov (United States)

    Chang, Gao-Wei; Liao, Chia-Cheng; Yeh, Zong-Mu

    2007-01-01

    For many years, the widening use of digital imaging products, e.g., digital cameras, has given rise to much attention in the market of consumer electronics. However, it is important to measure and enhance the imaging performance of the digital ones, compared to that of conventional cameras (with photographic films). For example, the effect of diffraction arising from the miniaturization of the optical modules tends to decrease the image resolution. As a figure of merit, modulation transfer function (MTF) has been broadly employed to estimate the image quality. Therefore, the objective of this paper is to design and implement an accurate and cost-effective MTF measurement system for the digital camera. Once the MTF of the sensor array is provided, that of the optical module can be then obtained. In this approach, a spatial light modulator (SLM) is employed to modulate the spatial frequency of light emitted from the light-source. The modulated light going through the camera under test is consecutively detected by the sensors. The corresponding images formed from the camera are acquired by a computer and then, they are processed by an algorithm for computing the MTF. Finally, through the investigation on the measurement accuracy from various methods, such as from bar-target and spread-function methods, it appears that our approach gives quite satisfactory results.

  18. An Analog-Digital Mixed Measurement Method of Inductive Proximity Sensor

    Directory of Open Access Journals (Sweden)

    Yi-Xin Guo

    2015-12-01

    Full Text Available Inductive proximity sensors (IPSs are widely used in position detection given their unique advantages. To address the problem of temperature drift, this paper presents an analog-digital mixed measurement method based on the two-dimensional look-up table. The inductance and resistance components can be separated by processing the measurement data, thus reducing temperature drift and generating quantitative outputs. This study establishes and implements a two-dimensional look-up table that reduces the online computational complexity through structural modeling and by conducting an IPS operating principle analysis. This table is effectively compressed by considering the distribution characteristics of the sample data, thus simplifying the processing circuit. Moreover, power consumption is reduced. A real-time, built-in self-test (BIST function is also designed and achieved by analyzing abnormal sample data. Experiment results show that the proposed method obtains the advantages of both analog and digital measurements, which are stable, reliable, and taken in real time, without the use of floating-point arithmetic and process-control-based components. The quantitative output of displacement measurement accelerates and stabilizes the system control and detection process. The method is particularly suitable for meeting the high-performance requirements of the aviation and aerospace fields.

  19. Bilateral Testicular Tumors Resulting in Recurrent Cushing Disease After Bilateral Adrenalectomy.

    Science.gov (United States)

    Puar, Troy; Engels, Manon; van Herwaarden, Antonius E; Sweep, Fred C G J; Hulsbergen-van de Kaa, Christina; Kamphuis-van Ulzen, Karin; Chortis, Vasileios; Arlt, Wiebke; Stikkelbroeck, Nike; Claahsen-van der Grinten, Hedi L; Hermus, Ad R M M

    2017-02-01

    Recurrence of hypercortisolism in patients after bilateral adrenalectomy for Cushing disease is extremely rare. We present a 27-year-old man who previously underwent bilateral adrenalectomy for Cushing disease with complete clinical resolution. Cushingoid features recurred 12 years later, with bilateral testicular enlargement. Hormonal tests confirmed adrenocorticotropic hormone (ACTH)-dependent Cushing disease. Surgical resection of the testicular tumors led to clinical and biochemical remission. Gene expression analysis of the tumor tissue by quantitative polymerase chain reaction showed high expression of all key steroidogenic enzymes. Adrenocortical-specific genes were 5.1 × 105 (CYP11B1), 1.8 × 102 (CYP11B2), and 6.3 × 104 (MC2R) times higher than nonsteroidogenic fibroblast control. This correlated with urine steroid metabolome profiling showing 2 fivefold increases in the excretion of the metabolites of 11-deoxycortisol, 21-deoxycortisol, and total glucocorticoids. Leydig-specific genes were 4.3 × 101 (LHCGR) and 9.3 × 100 (HSD17B3) times higher than control, and urinary steroid profiling showed twofold increased excretion of the major androgen metabolites androsterone and etiocholanolone. These distinctly increased steroid metabolites were suppressed by dexamethasone but unresponsive to human chorionic gonadotropin stimulation, supporting the role of ACTH, but not luteinizing hormone, in regulating tumor-specific steroid excess. We report bilateral testicular tumors occurring in a patient with recurrent Cushing disease 12 years after bilateral adrenalectomy. Using mRNA expression analysis and steroid metabolome profiling, the tumors demonstrated both adrenocortical and gonadal steroidogenic properties, similar to testicular adrenal rest tumors found in patients with congenital adrenal hyperplasia, suggesting the presence of pluripotent cells even in patients without congenital adrenal hyperplasia. Copyright © 2017 by the Endocrine Society

  20. Biomechanics of unilateral and bilateral sacroiliac joint stabilization: laboratory investigation.

    Science.gov (United States)

    Lindsey, Derek P; Parrish, Robin; Gundanna, Mukund; Leasure, Jeremi; Yerby, Scott A; Kondrashov, Dimitriy

    2018-03-01

    OBJECTIVE Bilateral symptoms have been reported in 8%-35% of patients with sacroiliac (SI) joint dysfunction. Stabilization of a single SI joint may significantly alter the stresses on the contralateral SI joint. If the contralateral SI joint stresses are significantly increased, degeneration may occur; alternatively, if the stresses are significantly reduced, bilateral stabilization may be unnecessary for patients with bilateral symptoms. The biomechanical effects of 1) unilateral stabilization on the contralateral SI joint and 2) bilateral stabilization on both SI joints are currently unknown. The objectives of this study were to characterize bilateral SI joint range of motion (ROM) and evaluate and compare the biomechanical effects of unilateral and bilateral implant placement for SI joint fusion. METHODS A lumbopelvic model (L5-pelvis) was used to test the ROM of both SI joints in 8 cadavers. A single-leg stance setup was used to load the lumbar spine and measure the ROM of each SI joint in flexion-extension, lateral bending, and axial rotation. Both joints were tested 1) while intact, 2) after unilateral stabilization, and 3) after bilateral stabilization. Stabilization consisted of lateral transiliac placement of 3 triangular titanium plasma-sprayed (TPS) implants. RESULTS Intact testing showed that during single-leg stance the contralateral SI joint had less ROM in flexion-extension (27%), lateral bending (32%), and axial rotation (69%) than the loaded joint. Unilateral stabilization resulted in significant reduction of flexion-extension ROM (46%) on the treated side; no significant ROM changes were observed for the nontreated side. Bilateral stabilization resulted in significant reduction of flexion-extension ROM of the primary (45%) and secondary (75%) SI joints. CONCLUSIONS This study demonstrated that during single-leg loading the ROMs for the stance (loaded) and swing (unloaded) SI joints are significantly different. Unilateral stabilization for SI

  1. A fast continuous magnetic field measurement system based on digital signal processors

    International Nuclear Information System (INIS)

    Velev, G.V.; Carcagno, R.; DiMarco, J.; Kotelnikov, S.; Lamm, M.; Makulski, A.; Maroussov, V.; Nehring, R.; Nogiec, J.; Orris, D.; Poukhov, O.; Prakoshyn, F.; Schlabach, P.; Tompkins, J.C.

    2005-01-01

    In order to study dynamic effects in accelerator magnets, such as the decay of the magnetic field during the dwell at injection and the rapid so-called ''snapback'' during the first few seconds of the resumption of the energy ramp, a fast continuous harmonics measurement system was required. A new magnetic field measurement system, based on the use of digital signal processors (DSP) and Analog to Digital (A/D) converters, was developed and prototyped at Fermilab. This system uses Pentek 6102 16 bit A/D converters and the Pentek 4288 DSP board with the SHARC ADSP-2106 family digital signal processor. It was designed to acquire multiple channels of data with a wide dynamic range of input signals, which are typically generated by a rotating coil probe. Data acquisition is performed under a RTOS, whereas processing and visualization are performed under a host computer. Firmware code was developed for the DSP to perform fast continuous readout of the A/D FIFO memory and integration over specified intervals, synchronized to the probe's rotation in the magnetic field. C, C++ and Java code was written to control the data acquisition devices and to process a continuous stream of data. The paper summarizes the characteristics of the system and presents the results of initial tests and measurements

  2. Evaluation of the styloid process on digital panoramic radiographs

    International Nuclear Information System (INIS)

    More, Chandramani B; Asrani, Mukesh K

    2010-01-01

    The styloid process is an anatomical structure, whose clinical importance is not well understood. Proper clinical and radiographic evaluation can detect an elongated styloid process and calcification of the stylohyoid ligament. It has been reported that 2 – 28% of the general population show radiographic evidence of mineralization of a portion of the stylohyoid chain. The elongated styloid process may be symptomatic in many cases. Panoramic radiography is the best imaging modality to view the styloid process bilaterally. To assess the styloid process on digital panoramic radiographs. The study was conducted on 500 digital panoramic radiographs available in the archives of our department as soft copies. These radiographs were taken using a digital panoramic system. The radiographic length of the styloid process was measured on both sides using the measurement toolbars on the accompanying analysis software. For statistical analysis we used the unpaired t test, Chi-square test, and one-way ANOVA test, as necessary. The average length of the left styloid was 25.41 ± 6.32 mm and that of the right styloid was 25.53 ± 6.62 mm. The length of both styloids increased with age and males had longer styloids than females. Elongated styloids were present in 19.4% of the panoramic radiographs. Langlais type I elongated styloids and a partial calcification pattern were more common than others. Panoramic radiography is useful for detection of an elongated styloid process and / or ossification of the stylohyoid ligament in patients with or without symptoms, and helps avoid a misdiagnosis of tonsillar pain or pain of dental, pharyngeal, or muscular origin

  3. Measuring hot flash phenomenonology using ambulatory prospective digital diaries

    Science.gov (United States)

    Fisher, William I.; Thurston, Rebecca C.

    2016-01-01

    Objective This study provides the description, protocol, and results from a novel prospective ambulatory digital hot flash phenomenon diary. Methods This study included 152 midlife women with daily hot flashes who completed an ambulatory electronic hot flash diary continuously for the waking hours of 3 consecutive days. In this diary, women recorded their hot flashes and accompanying characteristics and associations as the hot flashes occurred. Results Self-reported hot flash severity on the digital diaries indicated that the majority of hot flashes were rated as mild (41.3%) or moderate (43.7%). Severe (13.1%) and very severe (1.8%) hot flashes were less common. Hot flash bother ratings were rated as mild (43%), or moderate (33.5%), with fewer hot flashes reported bothersome (17.5%) or very bothersome (6%). The majority of hot flashes were reported as occurring on the on the face (78.9%), neck (74.7%), and chest (61.3%). Prickly skin was reported concurrently with 32% of hot flashes, 7% with anxiety and 5% with nausea. A novel finding, 38% of hot flashes were accompanied by a premonitory aura. Conclusion A prospective electronic digital hot flash diary allows for a more precise quantitation of hot flashes while overcoming many of the limitations of commonly employed retrospective questionnaires and paper diaries. Unique insights into the phenomenology, loci and associated characteristics of hot flashes were obtained using this device. The digital hot flash phenomenology diary is recommended for future ambulatory studies of hot flashes as a prospective measure of the hot flash experience. PMID:27404030

  4. Refining Measures for Assessing Problematic/Addictive Digital Gaming Use in Clinical and Research Settings

    Directory of Open Access Journals (Sweden)

    Kyle Faust

    2015-08-01

    Full Text Available Problematic or addictive digital gaming (including all types of electronic devices can and has had extremely adverse impacts on the lives of many individuals across the world. The understanding of this phenomenon, and the effectiveness of treatment design and monitoring, can be improved considerably by continuing refinement of assessment tools. The present article briefly overviews tools designed to measure problematic or addictive use of digital gaming, the vast majority of which are founded on the Diagnostic and Statistical Manual of Mental Disorders (DSM criteria for other addictive disorders, such as pathological gambling. Although adapting DSM content and strategies for measuring problematic digital gaming has proven valuable, there are some potential issues with this approach. We discuss the strengths and limitations of current methods for measuring problematic or addictive gaming and provide various recommendations that might help in enhancing or supplementing existing tools, or in developing new and even more effective tools.

  5. Digital Lengthening to Treat Finger Deficiency: An Experience of 201 Digits in 104 Patients

    Directory of Open Access Journals (Sweden)

    Zhenyu Ding

    2017-01-01

    Full Text Available Objectives. We evaluated the results of digital lengthening by distraction and second-stage bone graft. Methods. We treated finger deficiency of 201 digits in 104 patients (68 males, 36 females by digital distraction and second-stage bone graft. The distraction was performed with a rate of 1 mm/day (for the first ten days and 0.5 mm/day followed by using a self-designed bilateral tubal-helical external fixator. The mean follow-up period was 42 months (range 6 to 60 months. Results. The mean lengthening was 29.2 mm (range 25 to 40 mm and 18.7 mm (range 12 to 32 mm for metacarpal bones and phalanges, respectively. The mean elongation rate was 174.4% (range 145% to 202% and 184.8% (range 115% to 283% for metacarpal bones and phalanges, respectively. The static two-point discriminations and SpO2 showed no significant differences before and after distraction. Four complications were observed (two skin ruptures and two phalangeal splitting. No pin tract infection or tendon rupture showed. Digital lengthening improved functions of the hand. Conclusion. Digital distraction and second-stage bone graft is an effective method to compensate disabilities caused by lack of finger length. It could be an alternative plan for patients with thumb deficiency instead of toe-to-thumb transplant and patients with finger deficiency instead of ray resection.

  6. Digital instantaneous frequency measurement technique utilising high-speed ADC’s and FPGA’s

    CSIR Research Space (South Africa)

    Herselman, PL

    2006-02-27

    Full Text Available This paper presents the Digital Instantaneous Frequency Measurement (DIFM) technique, which can measure the carrier frequency of a received waveform within a fraction of a microsecond. The resulting frequency range, resolution and accuracy...

  7. Radiological findings for hip dysplasia at skeletal maturity. Validation of digital and manual measurement techniques.

    Science.gov (United States)

    Engesæter, Ingvild Øvstebø; Laborie, Lene Bjerke; Lehmann, Trude Gundersen; Sera, Francesco; Fevang, Jonas; Pedersen, Douglas; Morcuende, José; Lie, Stein Atle; Engesæter, Lars Birger; Rosendahl, Karen

    2012-07-01

    To report on intra-observer, inter-observer, and inter-method reliability and agreement for radiological measurements used in the diagnosis of hip dysplasia at skeletal maturity, as obtained by a manual and a digital measurement technique. Pelvic radiographs from 95 participants (56 females) in a follow-up hip study of 18- to 19-year-old patients were included. Eleven radiological measurements relevant for hip dysplasia (Sharp's, Wiberg's, and Ogata's angles; acetabular roof angle of Tönnis; articulo-trochanteric distance; acetabular depth-width ratio; femoral head extrusion index; maximum teardrop width; and the joint space width in three different locations) were validated. Three observers measured the radiographs using both a digital measurement program and manually in AgfaWeb1000. Inter-method and inter- and intra-observer agreement were analyzed using the mean differences between the readings/readers, establishing the 95% limits of agreement. We also calculated the minimum detectable change and the intra-class correlation coefficient. Large variations among different radiological measurements were demonstrated. However, the variation was not related to the use of either the manual or digital measurement technique. For measurements with greater absolute values (Sharp's angle, femoral head extrusion index, and acetabular depth-width ratio) the inter- and intra-observer and inter-method agreements were better as compared to measurements with lower absolute values (acetabular roof angle, teardrop and joint space width). The inter- and intra-observer variation differs notably across different radiological measurements relevant for hip dysplasia at skeletal maturity, a fact that should be taken into account in clinical practice. The agreement between the manual and digital methods is good.

  8. Radiological findings for hip dysplasia at skeletal maturity. Validation of digital and manual measurement techniques

    Energy Technology Data Exchange (ETDEWEB)

    Engesaeter, Ingvild Oevsteboe [University of Bergen, Department of Surgical Sciences, Bergen (Norway); Haukeland University Hospital, Department of Orthopaedic Surgery, Bergen (Norway); Haukeland University Hospital, Department of Radiology, Bergen (Norway); Haukeland University Hospital, The Norwegian Arthroplasty Register, Department of Orthopaedic Surgery, Bergen (Norway); Laborie, Lene Bjerke; Rosendahl, Karen [University of Bergen, Department of Surgical Sciences, Bergen (Norway); Haukeland University Hospital, Department of Radiology, Bergen (Norway); Lehmann, Trude Gundersen; Fevang, Jonas; Engesaeter, Lars Birger [University of Bergen, Department of Surgical Sciences, Bergen (Norway); Haukeland University Hospital, Department of Orthopaedic Surgery, Bergen (Norway); Sera, Francesco [University College London Institute of Child Health, Medical Research Council Centre of Epidemiology for Child Health, London (United Kingdom); Pedersen, Douglas; Morcuende, Jose [University of Iowa Hospital and Clinics, Department of Orthopaedics and Rehabilitation, Iowa City, IA (United States); Lie, Stein Atle [Uni Health, Uni Research, Bergen (Norway)

    2012-07-15

    To report on intra-observer, inter-observer, and inter-method reliability and agreement for radiological measurements used in the diagnosis of hip dysplasia at skeletal maturity, as obtained by a manual and a digital measurement technique. Pelvic radiographs from 95 participants (56 females) in a follow-up hip study of 18- to 19-year-old patients were included. Eleven radiological measurements relevant for hip dysplasia (Sharp's, Wiberg's, and Ogata's angles; acetabular roof angle of Toennis; articulo-trochanteric distance; acetabular depth-width ratio; femoral head extrusion index; maximum teardrop width; and the joint space width in three different locations) were validated. Three observers measured the radiographs using both a digital measurement program and manually in AgfaWeb1000. Inter-method and inter- and intra-observer agreement were analyzed using the mean differences between the readings/readers, establishing the 95% limits of agreement. We also calculated the minimum detectable change and the intra-class correlation coefficient. Large variations among different radiological measurements were demonstrated. However, the variation was not related to the use of either the manual or digital measurement technique. For measurements with greater absolute values (Sharp's angle, femoral head extrusion index, and acetabular depth-width ratio) the inter- and intra-observer and inter-method agreements were better as compared to measurements with lower absolute values (acetabular roof angle, teardrop and joint space width). The inter- and intra-observer variation differs notably across different radiological measurements relevant for hip dysplasia at skeletal maturity, a fact that should be taken into account in clinical practice. The agreement between the manual and digital methods is good. (orig.)

  9. A digital method for period measurements in a nuclear reactor

    International Nuclear Information System (INIS)

    Mundim, Sergio Gorretta

    1971-02-01

    The present paper begins by giving a theoretical treatment for the nuclear reactor period. The conventional method of measuring the period is analysed and some previously developed digital methods are described. The paper criticises the latter, pointing out some deficiencies which the proposed process is able to eliminate. All errors connected with this process are also analysed. The paper presents suitable solutions to reduce them to a minimum. The total error is found to he less than the error presented by the other methods described. A digital period meter is designed with memory resources and an automatic scaler changer. Integrated circuits specifications are used in it. Real time experiments with nuclear reactors were made in order to check te validity of the method. The data acquired were applied to a simulated digital period meter implemented in a general purpose computer. The nuclear part of the work was developed at the 'Comissao Nacional de Energia Nuclear' and the simulation work was dane at the 'Departamento de Calculo Cientifico' of COPPE, which also advised the author in the completion of this thesis. (author)

  10. Differences in Measuring Market Risk in Four Subsectors of the Digital Economy

    Directory of Open Access Journals (Sweden)

    Sonia Benito

    2015-03-01

    Full Text Available This paper defends the wisdom of not considering the Digital Economy to be one homogeneous sector. Our hypothesis is that it is best to consider it the result of adding four different subsectors. We test whether indeed the economic and financial performance of a portfolio of listed companies in each of the four subsectors presents relevant differences. We use the value at risk measure to estimate market risk of the four subsectors of the digital economy. The riskiest subsector is Mobile/Internet Contents & Services followed by SW&IT Services and Application Software. On the contrary, the Telecom sector is by far the safest one. These results support the hypothesis that the Digital Economy is not a homogeneous sector.

  11. Differences in Measuring Market Risk in Four Subsectors of the Digital Economy

    OpenAIRE

    Sonia Benito; Rebeca de Juan; Ricardo Gómez; Francisco Mochón

    2015-01-01

    This paper defends the wisdom of not considering the Digital Economy to be one homogeneous sector. Our hypothesis is that it is best to consider it the result of adding four different subsectors. We test whether indeed the economic and financial performance of a portfolio of listed companies in each of the four subsectors presents relevant differences. We use the value at risk measure to estimate market risk of the four subsectors of the digital economy. The riskiest subsector is Mobile/Inter...

  12. Delayed access to bilateral input alters cortical organization in children with asymmetric hearing

    Directory of Open Access Journals (Sweden)

    Melissa Jane Polonenko

    2018-01-01

    Full Text Available Bilateral hearing in early development protects auditory cortices from reorganizing to prefer the better ear. Yet, such protection could be disrupted by mismatched bilateral input in children with asymmetric hearing who require electric stimulation of the auditory nerve from a cochlear implant in their deaf ear and amplified acoustic sound from a hearing aid in their better ear (bimodal hearing. Cortical responses to bimodal stimulation were measured by electroencephalography in 34 bimodal users and 16 age-matched peers with normal hearing, and compared with the same measures previously reported for 28 age-matched bilateral implant users. Both auditory cortices increasingly favoured the better ear with delay to implanting the deaf ear; the time course mirrored that occurring with delay to bilateral implantation in unilateral implant users. Preference for the implanted ear tended to occur with ongoing implant use when hearing was poor in the non-implanted ear. Speech perception deteriorated with longer deprivation and poorer access to high-frequencies. Thus, cortical preference develops in children with asymmetric hearing but can be avoided by early provision of balanced bimodal stimulation. Although electric and acoustic stimulation differ, these inputs can work sympathetically when used bilaterally given sufficient hearing in the non-implanted ear.

  13. Is digital photography an accurate and precise method for measuring range of motion of the shoulder and elbow?

    Science.gov (United States)

    Russo, Russell R; Burn, Matthew B; Ismaily, Sabir K; Gerrie, Brayden J; Han, Shuyang; Alexander, Jerry; Lenherr, Christopher; Noble, Philip C; Harris, Joshua D; McCulloch, Patrick C

    2018-03-01

    Accurate measurements of shoulder and elbow motion are required for the management of musculoskeletal pathology. The purpose of this investigation was to compare three techniques for measuring motion. The authors hypothesized that digital photography would be equivalent in accuracy and show higher precision compared to the other two techniques. Using infrared motion capture analysis as the reference standard, shoulder flexion/abduction/internal rotation/external rotation and elbow flexion/extension were measured using visual estimation, goniometry, and digital photography on 10 fresh frozen cadavers. These measurements were performed by three physical therapists and three orthopaedic surgeons. Accuracy was defined by the difference from the reference standard (motion capture analysis), while precision was defined by the proportion of measurements within the authors' definition of clinical significance (10° for all motions except for elbow extension where 5° was used). Analysis of variance (ANOVA), t-tests, and chi-squared tests were used. Although statistically significant differences were found in measurement accuracy between the three techniques, none of these differences met the authors' definition of clinical significance. Precision of the measurements was significantly higher for both digital photography (shoulder abduction [93% vs. 74%, p < 0.001], shoulder internal rotation [97% vs. 83%, p = 0.001], and elbow flexion [93% vs. 65%, p < 0.001]) and goniometry (shoulder abduction [92% vs. 74%, p < 0.001] and shoulder internal rotation [94% vs. 83%, p = 0.008]) than visual estimation. Digital photography was more precise than goniometry for measurements of elbow flexion only [93% vs. 76%, p < 0.001]. There was no clinically significant difference in measurement accuracy between the three techniques for shoulder and elbow motion. Digital photography showed higher measurement precision compared to visual estimation for shoulder abduction, shoulder

  14. Method for Measuring the Information Content of Terrain from Digital Elevation Models

    Directory of Open Access Journals (Sweden)

    Lujin Hu

    2015-10-01

    Full Text Available As digital terrain models are indispensable for visualizing and modeling geographic processes, terrain information content is useful for terrain generalization and representation. For terrain generalization, if the terrain information is considered, the generalized terrain may be of higher fidelity. In other words, the richer the terrain information at the terrain surface, the smaller the degree of terrain simplification. Terrain information content is also important for evaluating the quality of the rendered terrain, e.g., the rendered web terrain tile service in Google Maps (Google Inc., Mountain View, CA, USA. However, a unified definition and measures for terrain information content have not been established. Therefore, in this paper, a definition and measures for terrain information content from Digital Elevation Model (DEM, i.e., a digital model or 3D representation of a terrain’s surface data are proposed and are based on the theory of map information content, remote sensing image information content and other geospatial information content. The information entropy was taken as the information measuring method for the terrain information content. Two experiments were carried out to verify the measurement methods of the terrain information content. One is the analysis of terrain information content in different geomorphic types, and the results showed that the more complex the geomorphic type, the richer the terrain information content. The other is the analysis of terrain information content with different resolutions, and the results showed that the finer the resolution, the richer the terrain information. Both experiments verified the reliability of the measurements of the terrain information content proposed in this paper.

  15. United Kingdom national paediatric bilateral cochlear implant audit: preliminary results.

    Science.gov (United States)

    Cullington, Helen; Bele, Devyanee; Brinton, Julie; Lutman, Mark

    2013-11-01

    Prior to 2009, United Kingdom (UK) public funding was mainly only available for children to receive unilateral cochlear implants. In 2009, the National Institute for Health and Care Excellence published guidance for cochlear implantation following their review. According to these guidelines, all suitable children are eligible to have simultaneous bilateral cochlear implants or a sequential bilateral cochlear implant if they had received the first before the guidelines were published. Fifteen UK cochlear implant centres formed a consortium to carry out a multi-centre audit. The audit involves collecting data from simultaneously and sequentially implanted children at four intervals: before bilateral cochlear implants or before the sequential implant, 1, 2, and 3 years after bilateral implants. The measures include localization, speech recognition in quiet and background noise, speech production, listening, vocabulary, parental perception, quality of life, and surgical data including complications. The audit has now passed the 2-year point, and data have been received on 850 children. This article provides a first view of some data received up until March 2012.

  16. Precise measurement of cat patellofemoral joint surface geometry with multistation digital photogrammetry.

    Science.gov (United States)

    Ronsky, J L; Boyd, S K; Lichti, D D; Chapman, M A; Salkauskas, K

    1999-04-01

    Three-dimensional joint models are important tools for investigating mechanisms related to normal and pathological joints. Often these models necessitate accurate three-dimensional joint surface geometric data so that reliable model results can be obtained; however, in models based on small joints, this is often problematic due to limitations of the present techniques. These limitations include insufficient measurement precision the requirement of contact for the measurement process, and lack of entire joint description. This study presents a new non-contact method for precise determination of entire joint surfaces using multistation digital photogrammetry (MDPG) and is demonstrated by determining the cartilage and subchondral bone surfaces of the cat patellofemoral (PF) joint. The digital camera-lens setup was precisely calibrated using 16 photographs arranged to achieve highly convergent geometry to estimate interior and distortion parameters of the camera-lens setup. Subsequently, six photographs of each joint surface were then acquired for surface measurement. The digital images were directly imported to a computer and newly introduced semi-automatic computer algorithms were used to precisely determine the image coordinates. Finally, a rigorous mathematical procedure named the bundle adjustment was used to determine the three-dimensional coordinates of the joint surfaces and to estimate the precision of the coordinates. These estimations were validated by comparing the MDPG measurements of a cylinder and plane to an analytical model. The joint surfaces were successfully measured using the MDPG method with mean precision estimates in the least favorable coordinate direction being 10.3 microns for subchondral bone and 17.9 microns for cartilage. The difference in measurement precision for bone and cartilage primarily reflects differences in the translucent properties of the surfaces.

  17. Effectiveness of preventative and other surgical measures on hypocalcemia following bilateral thyroid surgery: a systematic review and meta-analysis.

    Science.gov (United States)

    Antakia, Ramez; Edafe, Ovie; Uttley, Lesley; Balasubramanian, Saba P

    2015-01-01

    A variety of measures have been proposed to reduce the incidence of post-thyroidectomy hypocalcemia. The aim of this study was to perform a systematic review and meta-analysis of preventive and other surgical measures on post-thyroidectomy hypocalcemia as reported in the literature. Comprehensive searches of the PubMed, EMBASE, and Cochrane databases were performed, and the quality of included papers was assessed using the Cochrane risk of bias tool or a modified Newcastle-Ottawa Scale (NOS). The results of all included studies were summarized, and meta-analyses were performed where appropriate. Thirty-nine randomized controlled trials (RCTs) and 37 observational studies were included. Measures studied included hemostatic techniques, extent of thyroidectomy and central neck dissection, surgical approach, calcium/vitamin D/thiazide diuretic supplements, parathyroid gland autotransplantation (PGAT) and intraoperative parathyroid gland (PG) identification, truncal ligation of inferior thyroid artery (ITA), preoperative magnesium infusion, and use of magnification loupes and Surgicel. Measures associated with significantly lower rates of transient hypocalcemia in meta-analysis were postoperative calcium and vitamin D supplementation compared to either calcium supplements alone (odds ratio (OR) 0.66; p=0.04) or no supplements (OR 0.34; p=0.007), and bilateral subtotal thyroidectomy (BST) compared to Hartley Dunhill (HD) procedure (OR 0.35; p=0.01). Meta-analyses did not demonstrate any measure to be significantly associated with a reduction in permanent hypocalcemia. This review identified postoperative calcium and vitamin D supplementation and bilateral subtotal thyroidectomy (over HD) as being effective in prevention of transient hypocalcemia. However, the majority of RCTs were of low quality, primarily due to a lack of blinding. The wide variability in study design, definitions of hypocalcemia, and methods of assessment prevented meaningful summation of results for

  18. Functional outcomes after bilateral arthroscopic rotator cuff repair.

    Science.gov (United States)

    Aleem, Alexander W; Syed, Usman Ali M; Wascher, Jocelyn; Zoga, Adam C; Close, Koby; Abboud, Joseph A; Cohen, Steven B

    2016-10-01

    Arthroscopic repair of rotator cuff tears is a common procedure performed by orthopedic surgeons. There is a well-known incidence of up to 35% of bilateral rotator cuff tear disease in patients who have a known unilateral tear. The majority of the literature focuses on outcomes after unilateral surgery. The purpose of this study was to determine if there are clinical differences in shoulders of patients who underwent staged bilateral rotator cuff repairs during their lifetime. A retrospective review of all patients who underwent staged bilateral arthroscopic rotator cuff surgery at our institution was performed. All patients had at least 2 years of follow-up. Clinical outcome scores including the American Shoulder and Elbow Surgeons (ASES), Single Assessment Numeric Evaluation, and Rowe measures were obtained. A subset of patients returned for clinical and ultrasound evaluation performed by an independent fellowship-trained musculoskeletal radiologist. Overall, 110 shoulders in 55 patients, representing 68% of all eligible patients, participated. No clinical or statistical difference was found in any outcome measure. ASES scores averaged 86.5 (36.7-100) in the dominant shoulder compared with 89.6 (23.3-100) in the nondominant shoulder (P = .42). Ultrasound was available on 34 shoulders and showed complete healing rate of 88%. The shoulders with retearing of the rotator cuff (12%) demonstrated clinically relevant lower ASES scores (72.5) compared with shoulders with confirmed healed repairs (86.2; P = .2). Patients who undergo staged bilateral rotator cuff repair can expect to have similarly good clinical outcomes regardless of hand dominance or chronologic incidence with excellent healing rates in both shoulders. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  19. ImageJ: A Free, Easy, and Reliable Method to Measure Leg Ulcers Using Digital Pictures.

    Science.gov (United States)

    Aragón-Sánchez, Javier; Quintana-Marrero, Yurena; Aragón-Hernández, Cristina; Hernández-Herero, María José

    2017-12-01

    Wound measurement to document the healing course of chronic leg ulcers has an important role in the management of these patients. Digital cameras in smartphones are readily available and easy to use, and taking pictures of wounds is becoming a routine in specialized departments. Analyzing digital pictures with appropriate software provides clinicians a quick, clean, and easy-to-use tool for measuring wound area. A set of 25 digital pictures of plain foot and leg ulcers was the basis of this study. Photographs were taken placing a ruler next to the wound in parallel with the healthy skin with the iPhone 6S (Apple Inc, Cupertino, CA), which has a camera of 12 megapixels using the flash. The digital photographs were visualized with ImageJ 1.45s freeware (National Institutes of Health, Rockville, MD; http://imagej.net/ImageJ ). Wound area measurement was carried out by 4 raters: head of the department, wound care nurse, physician, and medical student. We assessed intra- and interrater reliability using the interclass correlation coefficient. To determine intraobserver reliability, 2 of the raters repeated the measurement of the set 1 week after the first reading. The interrater model displayed an interclass correlation coefficient of 0.99 with 95% confidence interval of 0.999 to 1.000, showing excellent reliability. The intrarater model of both examiners showed excellent reliability. In conclusion, analyzing digital images of leg ulcers with ImageJ estimates wound area with excellent reliability. This method provides a free, rapid, and accurate way to measure wounds and could routinely be used to document wound healing in daily clinical practice.

  20. Digital radiography density measurements in differentiation between periapical granulomas and radicular cysts.

    Science.gov (United States)

    Rózyło-Kalinowska, Ingrid

    2007-05-01

    The distinction between radicular cysts and apical granulomas is a matter of considerable importance in making a treatment decision. Because there are no clearly defined radiographic criteria, the distinction is made on the grounds of size. However, it has been suggested that cysts can be distinguished from granulomas on the basis of their radiometric density. The results of previous studies have proved conflicting. To determine possibilities of application of digital radiography density measurements in differentiation of periapical granulomas and radicular cysts of inflammatory origin. The material consisted of 355 digital periapical radiograms obtained using Digora, RVG and Dixi 2 digital radiography systems in patients aged 20 to 84, divided into two groups: 259 granulomas and 102 radicular cysts. By means of Digora 2.0 software there were measured maximum and minimum densities along a line, then there was calculated the difference between maximum and minimum density. The largest dimensions of the lesions were measured - perpendicular and parallel to the root canal axis. It was proved that to some extent it was possible to differentiate cystic granulomas and radicular cysts on the basis of the difference between maximum and minimum density in linear measurement - when the difference exceeded 85.6 the lesion was a cyst and when it was below 45.9 a granuloma was diagnosed. Combination of two criteria - the calculated difference between densities and the largest dimension of a lesion, increased diagnostic possibilities of radiological differentiation of granulomas and radicular cysts.

  1. Prenatal natural history of isolated fetal mild bilateral pyelectasis

    Directory of Open Access Journals (Sweden)

    Gustavo de Paula Pereira

    Full Text Available OBJECTIVE: To analyze the prenatal outcomes in a cohort of fetuses with mild bilateral pyelectasis and determine whether performing serial ultrasounds is a good follow-up strategy. METHODS: A prospective longitudinal study was conducted on 62 fetuses with mild bilateral pyelectasis. Fetal mild bilateral pyelectasis was considered when the renal pelvis measured (in millimeters ≥5.0 to 10.0, ≥7.0 to 10.0, and ≥10.0 to 15 at ≤23 weeks 6 days, 24 to 31 weeks 6 days, and ≥32 weeks, respectively, with no uretero-calyceal dilatation. Ultrasounds were performed every 3 weeks to assess whether the mild bilateral pyelectasis regressed, remained unchanged (Group 1 or progressed (Group 2. RESULTS: Group 1 consisted of 53 fetuses (85.4%, and progression was observed in 9 cases (Group 2, 14.6%. The initial renal pelvis diameter was significantly larger in fetuses with progression (p=0.028. Statistically significant differences in the renal pelvis diameter were also found at weeks 31 and 35 for both kidneys (p<0.05. The cases requiring intrauterine procedures or early delivery were not observed. CONCLUSION: Fetal mild bilateral pyelectasis with no calyceal dilatation is a benign condition that can be managed in the postnatal period. The initial renal pelvis diameter and the diameter in week 31 or 35 were valuable parameters for identifying cases that would eventually need specific postnatal procedures.

  2. Measurements of simulated periodontal bone defects in inverted digital image and film-based radiograph: an in vitro study

    International Nuclear Information System (INIS)

    Molon, Rafael Scaf; Morais Camillo, Juliana Aparecida Najarro Dearo; Ferreira, Mauricio Goncalves; Loffredo, Leonor Castro Monteiro; Scaf, Gulnara; Sakakura, Celso Eduardo

    2012-01-01

    This study was performed to compare the inverted digital images and film-based images of dry pig mandibles to measure the periodontal bone defect depth. Forty 2-wall bone defects were made in the proximal region of the premolar in the dry pig mandibles. The digital and conventional radiographs were taken using a Schick sensor and Kodak F-speed intraoral film. Image manipulation (inversion) was performed using Adobe Photoshop 7.0 software. Four trained examiners made all of the radiographic measurements in millimeters a total of three times from the cementoenamel junction to the most apical extension of the bone loss with both types of images: inverted digital and film. The measurements were also made in dry mandibles using a periodontal probe and digital caliper. The Student's t-test was used to compare the depth measurements obtained from the two types of images and direct visual measurement in the dry mandibles. A significance level of 0.05 for a 95% confidence interval was used for each comparison. There was a significant difference between depth measurements in the inverted digital images and direct visual measurements (p>|t|=0.0039), with means of 6.29 mm (IC 95% :6.04-6.54) and 6.79 mm (IC 95% :6.45-7.11), respectively. There was a non-significant difference between the film-based radiographs and direct visual measurements (p>|t|=0.4950), with means of 6.64 mm(IC 95% :6.40-6.89) and 6.79 mm(IC 95% :6.45-7.11), respectively. The periodontal bone defect measurements in the inverted digital images were inferior to film-based radiographs, underestimating the amount of bone loss.

  3. Bilateral tension pneumothorax related to acupuncture.

    Science.gov (United States)

    Tagami, Rumi; Moriya, Takashi; Kinoshita, Kosaku; Tanjoh, Katsuhisa

    2013-06-01

    We report on a patient with a rare case of bilateral tension pneumothorax that occurred after acupuncture. A 69-year-old large-bodied man, who otherwise had no risk factors for spontaneous pneumothorax, presented with chest pressure, cold sweats and shortness of breath. Immediately after bilateral pneumothorax had been identified on a chest radiograph in the emergency room, his blood pressure and percutaneous oxygen saturation suddenly decreased to 78 mm Hg and 86%, respectively. We confirmed deterioration in his cardiopulmonary status and diagnosed bilateral tension pneumothorax. We punctured his chest bilaterally and inserted chest tubes for drainage. His vital signs promptly recovered. After the bilateral puncture and drainage, we learnt that he had been treated with acupuncture on his upper back. We finally diagnosed a bilateral tension pneumothorax based on the symptoms that appeared 8 h after the acupuncture. Because the patient had no risk factors for spontaneous pneumothorax, no alternative diagnosis was proposed. We recommend that patients receiving acupuncture around the chest wall must be adequately informed of the possibility of complications and expected symptoms, as a definitive diagnosis can be difficult without complete information.

  4. Bilateral, independent juvenile nasopharyngeal angiofibroma: case report.

    Science.gov (United States)

    Mørkenborg, M-L; Frendø, M; Stavngaard, T; Von Buchwald, C

    2015-10-01

    Juvenile nasopharyngeal angiofibroma is a benign, vascular tumour that primarily occurs in adolescent males. Despite its benign nature, aggressive growth patterns can cause potential life-threatening complications. Juvenile nasopharyngeal angiofibroma is normally unilateral, originating from the sphenopalatine artery, but bilateral symptoms can occur if a large tumour extends to the contralateral side of the nasopharynx. This paper presents the first reported case of true bilateral extensive juvenile nasopharyngeal angiofibroma involving clinically challenging pre-surgical planning and surgical strategy. A 21-year-old male presented with increasing bilateral nasal obstruction and discharge. Examination revealed tumours bilaterally and imaging demonstrated non-contiguous tumours. Pre-operative angiography showed strictly ipsilateral vascular supplies requiring bilateral embolisation. Radical removal performed as one-step, computer-assisted functional endoscopic sinus surgery was performed. The follow-up period was uncomplicated. This case illustrates the importance of suspecting bilateral juvenile nasopharyngeal angiofibroma in patients presenting with bilateral symptoms. Our management, including successful pre-operative planning, enabled one-step total removal of both tumours and rapid patient recovery.

  5. Bilateral internal laryngoceles mimicking asthma

    Directory of Open Access Journals (Sweden)

    Elif A Aksoy

    2013-01-01

    Full Text Available Laryngocele is an air-filled, abnormal dilation of the laryngeal saccule that extends upward within the false vocal fold, in communication with the laryngeal lumen. A case of 43-year-old male with bilateral internal laryngoceles, who has been treated as asthma for 4 years, is presented. The patient had dyspnea, cough, and excessive phlegm for a month and a late onset stridor. Flexible nasopharyngolaryngoscopy showed bilateral cystic enlargements of the false vocal folds and true vocal folds could not be visualized. Laryngeal CT without contrast enhancement showed bilateral internal laryngoceles. Submucosal total excision of bilateral cystic masses including parts of false vocal folds was performed. The symptoms resolved immediately after surgery. Although the incidence of internal laryngocele is rare, it should be remembered in the differential diagnosis of upper airway problems and diagnostic flexible nasopharnygolaryngoscopy is routinely indicated for airway evaluation in at-risk patients.

  6. A fast continuous magnetic field measurement system based on digital signal processors

    Energy Technology Data Exchange (ETDEWEB)

    Velev, G.V.; Carcagno, R.; DiMarco, J.; Kotelnikov, S.; Lamm, M.; Makulski, A.; /Fermilab; Maroussov, V.; /Purdue U.; Nehring, R.; Nogiec, J.; Orris, D.; /Fermilab; Poukhov,; Prakoshyn, F.; /Dubna, JINR; Schlabach, P.; Tompkins, J.C.; /Fermilab

    2005-09-01

    In order to study dynamic effects in accelerator magnets, such as the decay of the magnetic field during the dwell at injection and the rapid so-called ''snapback'' during the first few seconds of the resumption of the energy ramp, a fast continuous harmonics measurement system was required. A new magnetic field measurement system, based on the use of digital signal processors (DSP) and Analog to Digital (A/D) converters, was developed and prototyped at Fermilab. This system uses Pentek 6102 16 bit A/D converters and the Pentek 4288 DSP board with the SHARC ADSP-2106 family digital signal processor. It was designed to acquire multiple channels of data with a wide dynamic range of input signals, which are typically generated by a rotating coil probe. Data acquisition is performed under a RTOS, whereas processing and visualization are performed under a host computer. Firmware code was developed for the DSP to perform fast continuous readout of the A/D FIFO memory and integration over specified intervals, synchronized to the probe's rotation in the magnetic field. C, C++ and Java code was written to control the data acquisition devices and to process a continuous stream of data. The paper summarizes the characteristics of the system and presents the results of initial tests and measurements.

  7. Kalman filtering techniques for reducing variance of digital speckle displacement measurement noise

    Institute of Scientific and Technical Information of China (English)

    Donghui Li; Li Guo

    2006-01-01

    @@ Target dynamics are assumed to be known in measuring digital speckle displacement. Use is made of a simple measurement equation, where measurement noise represents the effect of disturbances introduced in measurement process. From these assumptions, Kalman filter can be designed to reduce variance of measurement noise. An optical and analysis system was set up, by which object motion with constant displacement and constant velocity is experimented with to verify validity of Kalman filtering techniques for reduction of measurement noise variance.

  8. Simultaneous and staged bilateral total hip arthroplasty

    DEFF Research Database (Denmark)

    Lindberg-Larsen, Martin; Joergensen, Christoffer Calov; Husted, Henrik

    2013-01-01

    Bilateral total hip arthroplasty (BTHA) and bilateral simultaneous total hip arthroplasty (BSTHA) are done increasingly. Previous studies evaluating outcomes after bilateral procedures have found different results. The aim of this study was to investigate length of hospital stay (LOS), 30 days...

  9. Bilateral spontaneous hemotympanum: Case report

    Directory of Open Access Journals (Sweden)

    Economou Nicolas C

    2006-10-01

    Full Text Available Abstract Background The most common causes of hemotympanum are therapeutic nasal packing, epistaxis, blood disorders and blunt trauma to the head. Hemotympanum is characterized as idiopathic, when it is detected in the presence of chronic otitis media. A rare case of spontaneous bilateral hemotympanum in a patient treated with anticoagulants is presented herein. Case presentation A 72-year-old male presented with acute deterioration of hearing. In the patient's medical history aortic valve replacement 1 year before presentation was reported. Since then he had been administered regularly coumarinic anticoagulants, with INR levels maintained between 3.4 and 4.0. Otoscopy revealed the presence of bilateral hemotympanum. The audiogram showed symmetrical moderately severe mixed hearing loss bilaterally, with the conductive component predominating. Tympanograms were flat bilaterally with absent acoustic reflexes. A computerized tomography scan showed the presence of fluid in the mastoid and middle ear bilaterally. Treatment was conservative and consisted of a 10-day course of antibiotics, anticongestants and temporary interruption of the anticoagulant therapy. After 3 weeks, normal tympanic membranes were found and hearing had returned to previous levels. Conclusion Anticoagulant intake should be included in the differential diagnosis of hemotympanum, because its detection and appropriate treatment may lead to resolution of the disorder.

  10. Measuring food intake with digital photography.

    Science.gov (United States)

    Martin, C K; Nicklas, T; Gunturk, B; Correa, J B; Allen, H R; Champagne, C

    2014-01-01

    The digital photography of foods method accurately estimates the food intake of adults and children in cafeterias. When using this method, images of food selection and leftovers are quickly captured in the cafeteria. These images are later compared with images of 'standard' portions of food using computer software. The amount of food selected and discarded is estimated based upon this comparison, and the application automatically calculates energy and nutrient intake. In the present review, we describe this method, as well as a related method called the Remote Food Photography Method (RFPM), which relies on smartphones to estimate food intake in near real-time in free-living conditions. When using the RFPM, participants capture images of food selection and leftovers using a smartphone and these images are wirelessly transmitted in near real-time to a server for analysis. Because data are transferred and analysed in near real-time, the RFPM provides a platform for participants to quickly receive feedback about their food intake behaviour and to receive dietary recommendations for achieving weight loss and health promotion goals. The reliability and validity of measuring food intake with the RFPM in adults and children is also reviewed. In sum, the body of research reviewed demonstrates that digital imaging accurately estimates food intake in many environments and it has many advantages over other methods, including reduced participant burden, elimination of the need for participants to estimate portion size, and the incorporation of computer automation to improve the accuracy, efficiency and cost-effectiveness of the method. © 2013 The British Dietetic Association Ltd.

  11. Silicosis with bilateral spontaneous pneumothorax

    Directory of Open Access Journals (Sweden)

    Fotedar Sanjay

    2010-01-01

    Full Text Available Presentation with simultaneous bilateral pneumothorax is uncommon and usually in the context of secondary spontaneous pneumothorax.The association of pneumothorax and silicosis is infrequent and most cases are unilateral. Bilateral pneumothorax in silicosis is very rare with just a few reports in medical literature.

  12. Measurements of simulated periodontal bone defects in inverted digital image and film-based radiograph: an in vitro study

    Energy Technology Data Exchange (ETDEWEB)

    Molon, Rafael Scaf; Morais Camillo, Juliana Aparecida Najarro Dearo; Ferreira, Mauricio Goncalves; Loffredo, Leonor Castro Monteiro; Scaf, Gulnara [Araraquara Dental School, Universidade Estadual Paulista, Sao Paulo (Brazil); Sakakura, Celso Eduardo [Barretos Dental School, Barretos Educational Fundation, Sao Paulo (Brazil)

    2012-09-15

    This study was performed to compare the inverted digital images and film-based images of dry pig mandibles to measure the periodontal bone defect depth. Forty 2-wall bone defects were made in the proximal region of the premolar in the dry pig mandibles. The digital and conventional radiographs were taken using a Schick sensor and Kodak F-speed intraoral film. Image manipulation (inversion) was performed using Adobe Photoshop 7.0 software. Four trained examiners made all of the radiographic measurements in millimeters a total of three times from the cementoenamel junction to the most apical extension of the bone loss with both types of images: inverted digital and film. The measurements were also made in dry mandibles using a periodontal probe and digital caliper. The Student's t-test was used to compare the depth measurements obtained from the two types of images and direct visual measurement in the dry mandibles. A significance level of 0.05 for a 95% confidence interval was used for each comparison. There was a significant difference between depth measurements in the inverted digital images and direct visual measurements (p>|t|=0.0039), with means of 6.29 mm (IC{sub 95%}:6.04-6.54) and 6.79 mm (IC{sub 95%}:6.45-7.11), respectively. There was a non-significant difference between the film-based radiographs and direct visual measurements (p>|t|=0.4950), with means of 6.64 mm(IC{sub 95%}:6.40-6.89) and 6.79 mm(IC{sub 95%}:6.45-7.11), respectively. The periodontal bone defect measurements in the inverted digital images were inferior to film-based radiographs, underestimating the amount of bone loss.

  13. Accuracy of digital American Board of Orthodontics Discrepancy Index measurements.

    Science.gov (United States)

    Dragstrem, Kristina; Galang-Boquiren, Maria Therese S; Obrez, Ales; Costa Viana, Maria Grace; Grubb, John E; Kusnoto, Budi

    2015-07-01

    A digital analysis that is shown to be accurate will ease the demonstration of initial case complexity. To date, no literature exists on the accuracy of the digital American Board of Orthodontics Discrepancy Index (DI) calculations when applied to pretreatment digital models. Plaster models were obtained from 45 previous patients with varying degrees of malocclusion. Total DI scores and the target disorders were computed manually with a periodontal probe on the original plaster casts (gold standard) and digitally using Ortho Insight 3D (Motion View Software, Hixson, Tenn) and OrthoCAD (Cadent, Carlstadt, NJ). Intrarater and interrater reliabilities were assessed for 15 subjects using the Spearman rho correlation test. Accuracies of the DI scores and target disorders were assessed for all 45 subjects using Wilcoxon signed ranks tests. Intrarater and interrater reliabilities were high for total DI scores and most target disorders (r > 0.8). No significant difference was found between total DI score when measured with OrthoCAD compared with manual calculations. The total DI scores calculated by Ortho Insight 3D were found to be significantly greater than those by manual calculation by 2.71 points. The findings indicate that a DI calculated by Ortho Insight 3D may lead the clinician to overestimate case complexity. OrthoCAD's DI module was demonstrated to be a clinically acceptable alternative to manual calculation of the total scores. Copyright © 2015 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  14. Optical Measurement Techniques for Rocket Engine Testing and Component Applications: Digital Image Correlation and Dynamic Photogrammetry

    Science.gov (United States)

    Gradl, Paul

    2016-01-01

    NASA Marshall Space Flight Center (MSFC) has been advancing dynamic optical measurement systems, primarily Digital Image Correlation, for extreme environment rocket engine test applications. The Digital Image Correlation (DIC) technology is used to track local and full field deformations, displacement vectors and local and global strain measurements. This technology has been evaluated at MSFC through lab testing to full scale hotfire engine testing of the J-2X Upper Stage engine at Stennis Space Center. It has been shown to provide reliable measurement data and has replaced many traditional measurement techniques for NASA applications. NASA and AMRDEC have recently signed agreements for NASA to train and transition the technology to applications for missile and helicopter testing. This presentation will provide an overview and progression of the technology, various testing applications at NASA MSFC, overview of Army-NASA test collaborations and application lessons learned about Digital Image Correlation.

  15. Bilateral Keratectasia 34 Years after Corneal Transplant

    Directory of Open Access Journals (Sweden)

    Xavier Valldeperas

    2010-07-01

    Full Text Available We report the clinical findings of a patient with severe bilateral keratectasia 34 years after a penetrating keratoplasty (PK in both eyes. An otherwise healthy 67-year-old man complained of deterioration of the eyesight in both eyes over the last 6 months. The patient was diagnosed with bilateral keratoconus at the age of 32 years, and he underwent a bilateral PK. At presentation, visual acuity was 20/200 in the right eye and light perception in the left eye. A Pentacam pachymetric map revealed a central pachymetry of 720 µm in the right eye and of 710 µm in the left eye, as well as an average paracentral pachymetry of 436 and 270 µm in the 9-mm zone in the right and the left eye, respectively. Corneal topography revealed bilateral irregular and asymmetric bowing with generalized steepening and high corneal power. We describe a case of bilateral keratectasia 34 years after PK in a patient who was originally diagnosed with bilateral keratoconus.

  16. A boy with bilateral SUNA

    DEFF Research Database (Denmark)

    Vuković Cvetković, Vlasta; Jensen, Rigmor Højland

    2017-01-01

    secondary causes should be searched for vigorously if there are bilateral symptoms. Despite a number of therapeutic trials, effective management for the majority of SUNA patients is not available at present. Management of SUNA is often difficult. Case We report the case of a young boy with bilateral SUNA...

  17. Apparent diffusion coefficient measurements of bilateral kidneys at 3 T MRI: Effects of age, gender, and laterality in healthy adults

    International Nuclear Information System (INIS)

    Suo, S.-T.; Cao, M.-Q.; Ding, Y.-Z.; Yao, Q.-Y.; Wu, G.-Y.; Xu, J.-R.

    2014-01-01

    Aim: To investigate the effects of age and gender on apparent diffusion coefficient (ADC) measurements of bilateral kidneys at 3 T MRI, and compare the ADC values of left and right kidneys. Materials and methods: In all, 137 healthy participants (mean age 42.8 ± 14.7 years; age range 16–75 years) comprising 68 male and 69 female participants were enrolled. Three Tesla echo-planar diffusion-weighted imaging (DWI) of bilateral kidneys was performed and ADC values were measured in the cortex, medulla, and whole parenchyma. Pearson correlation analysis and linear regression were performed to determine the associations between the ADC values in each region and age. Effects of age and gender on ADC values were analysed using two-factor analysis of variance (ANOVA). The paired-samples t-test was established to compare the ADC values between left and right kidneys. Results: ADC values were significantly higher in the young group (≤50 years) than in the old group (>50 years), and correlated inversely with the age in all regions. Male participants had higher ADC values than female participants in all regions except left medulla. Two-factor ANOVA of age × gender showed no significant interactions between the variables age and gender were found. No significant differences in ADC values between left and right kidneys were observed. Conclusion: Renal ADC values are age- and gender-dependent, and show no significant difference between left and right kidneys. Age- and gender-related effects should be taken into consideration in future renal DWI studies when using normal ADC values from health controls. - Highlights: • Renal apparent diffusion coefficient (ADC) values decrease with ageing. • Men tend to have higher renal ADC values than women. • Bilateral kidneys seem to have no significantly different ADC values

  18. Binaural Pitch Fusion in Bilateral Cochlear Implant Users.

    Science.gov (United States)

    Reiss, Lina A J; Fowler, Jennifer R; Hartling, Curtis L; Oh, Yonghee

    Binaural pitch fusion is the fusion of stimuli that evoke different pitches between the ears into a single auditory image. Individuals who use hearing aids or bimodal cochlear implants (CIs) experience abnormally broad binaural pitch fusion, such that sounds differing in pitch by as much as 3-4 octaves are fused across ears, leading to spectral averaging and speech perception interference. The goal of this study was to determine if adult bilateral CI users also experience broad binaural pitch fusion. Stimuli were pulse trains delivered to individual electrodes. Fusion ranges were measured using simultaneous, dichotic presentation of reference and comparison stimuli in opposite ears, and varying the comparison stimulus to find the range that fused with the reference stimulus. Bilateral CI listeners had binaural pitch fusion ranges varying from 0 to 12 mm (average 6.1 ± 3.9 mm), where 12 mm indicates fusion over all electrodes in the array. No significant correlations of fusion range were observed with any subject factors related to age, hearing loss history, or hearing device history, or with any electrode factors including interaural electrode pitch mismatch, pitch match bandwidth, or within-ear electrode discrimination abilities. Bilateral CI listeners have abnormally broad fusion, similar to hearing aid and bimodal CI listeners. This broad fusion may explain the variability of binaural benefits for speech perception in quiet and in noise in bilateral CI users.

  19. Bilateral juvenile nasopharyngeal angiofibroma: report of a case.

    Science.gov (United States)

    Wu, Edward C; Chark, Davin W; Bhandarkar, Naveen D

    2014-07-01

    Juvenile nasopharyngeal angiofibroma (JNA) is the most common benign neoplasm of the nasopharynx. Almost always unilateral on diagnosis, JNAs are locally invasive and may extend across the midline, giving a false bilateral appearance; as such, true bilateral JNA is exceedingly rare. We present a recent case of true bilateral JNA. Single case report of a patient with bilateral JNA, including clinical presentation, diagnosis, and management. The patient presented with unilateral nasal obstruction and recurrent epistaxis. Computed tomography and magnetic resonance imaging demonstrated bilateral, noncontiguous masses. Angiography revealed independent vascular supplies from each respective side with no bilateral supply noted. The patient underwent preoperative embolization followed by endoscopic surgical removal of the larger mass; no complications were noted. Follow-up at 2 years demonstrated no recurrence or growth. The vast majority of JNAs are unilateral, though invasive growth to the contralateral side may appear "bilateral" in presentation. Proper identification of true bilateral JNA is helpful in guiding management, wherein excision of both tumors may not be necessary. © 2014 ARS-AAOA, LLC.

  20. Measuring Trust: Standards for Trusted Digital Repositories

    Science.gov (United States)

    Dryden, Jean

    2011-01-01

    Ensuring the long-term preservation and use of born-digital and digitized records of enduring value has preoccupied archivists and their cultural heritage siblings for several decades. The professional literature of the 1980s and 1990s bemoans the challenges posed by rapid technological change (and the concomitant obsolescence of hardware and…

  1. Simultaneous measurement of refractive index and thickness distributions using low-coherence digital holography and vertical scanning

    International Nuclear Information System (INIS)

    Watanabe, Kaho; Ohshima, Masashi; Nomura, Takanori

    2014-01-01

    The simultaneous measurement method of a refractive index distribution and a thickness distribution using low-coherence digital holography with a vertical scanning is proposed. The proposed method consists of a combination of digital holography and low-coherence interferometry. The introduction of a datum plane enables the measurement of both a refractive index distribution and a thickness distribution. By the optical experiment, the potential of the proposed method is confirmed. (paper)

  2. Miniaturized multiwavelength digital holography sensor for extensive in-machine tool measurement

    Science.gov (United States)

    Seyler, Tobias; Fratz, Markus; Beckmann, Tobias; Bertz, Alexander; Carl, Daniel

    2017-06-01

    In this paper we present a miniaturized digital holographic sensor (HoloCut) for operation inside a machine tool. With state-of-the-art 3D measurement systems, short-range structures such as tool marks cannot be resolved inside a machine tool chamber. Up to now, measurements had to be conducted outside the machine tool and thus processing data are generated offline. The sensor presented here uses digital multiwavelength holography to get 3D-shape-information of the machined sample. By using three wavelengths, we get a large artificial wavelength with a large unambiguous measurement range of 0.5mm and achieve micron repeatability even in the presence of laser speckles on rough surfaces. In addition, a digital refocusing algorithm based on phase noise is implemented to extend the measurement range beyond the limits of the artificial wavelength and geometrical depth-of-focus. With complex wave field propagation, the focus plane can be shifted after the camera images have been taken and a sharp image with extended depth of focus is constructed consequently. With 20mm x 20mm field of view the sensor enables measurement of both macro- and micro-structure (such as tool marks) with an axial resolution of 1 µm, lateral resolution of 7 µm and consequently allows processing data to be generated online which in turn qualifies it as a machine tool control. To make HoloCut compact enough for operation inside a machining center, the beams are arranged in two planes: The beams are split into reference beam and object beam in the bottom plane and combined onto the camera in the top plane later on. Using a mechanical standard interface according to DIN 69893 and having a very compact size of 235mm x 140mm x 215mm (WxHxD) and a weight of 7.5 kg, HoloCut can be easily integrated into different machine tools and extends no more in height than a typical processing tool.

  3. Evaluation of the styloid process on digital panoramic radiographs

    Directory of Open Access Journals (Sweden)

    More Chandramani

    2010-01-01

    Full Text Available Background: The styloid process is an anatomical structure, whose clinical importance is not well understood. Proper clinical and radiographic evaluation can detect an elongated styloid process and calcification of the stylohyoid ligament. It has been reported that 2 - 28% of the general population show radiographic evidence of mineralization of a portion of the stylohyoid chain. The elongated styloid process may be symptomatic in many cases. Panoramic radiography is the best imaging modality to view the styloid process bilaterally. Aim: To assess the styloid process on digital panoramic radiographs. Materials and Methods: The study was conducted on 500 digital panoramic radiographs available in the archives of our department as soft copies. These radiographs were taken using a digital panoramic system. The radiographic length of the styloid process was measured on both sides using the measurement toolbars on the accompanying analysis software. For statistical analysis we used the unpaired t test, Chi-square test, and one-way ANOVA test, as necessary. Results: The average length of the left styloid was 25.41 ± 6.32 mm and that of the right styloid was 25.53 ± 6.62 mm. The length of both styloids increased with age and males had longer styloids than females. Elongated styloids were present in 19.4% of the panoramic radiographs. Langlais type I elongated styloids and a partial calcification pattern were more common than others. Conclusion: Panoramic radiography is useful for detection of an elongated styloid process and / or ossification of the stylohyoid ligament in patients with or without symptoms, and helps avoid a misdiagnosis of tonsillar pain or pain of dental, pharyngeal, or muscular origin.

  4. Academic Digital Library Construction Evaluation: Measures and Approaches

    OpenAIRE

    Wang , Qiyun

    2008-01-01

    Through review norms, standards and practice related to academic digital library construction evaluation at home and abroad, on the basis of investigation and study on the digital library evaluation at home and abroad, for status quo of the academic digital library construction, using qualitative analysis and quantitative analysis method, with methods and indicators for the traditional library evaluation system as a reference coordinates, put forward a comprehensive evaluation index system of...

  5. Bilateral complex regional pain syndrome following spinal cord injury and bilateral calcaneus fracture

    Directory of Open Access Journals (Sweden)

    Ahmet Boyacı

    2013-09-01

    Full Text Available Complex regional pain syndrome (CRPS is a disease affectingone or more extremities, characterized by spontaneouspain, allodynia, hyperpathia and hyperalgesia.CRPS is separated into Type 1 and Type 2. CRPS whichdevelops after a nociceptive event is labeled as Type 1and when it develops following peripheral nerve damage,Type 2. Although the pathogenesis is not fully understood,peripheral and central sensitivity are held responsible.Bilateral lower extremity involvement is extremely rare.However, it should be borne in mind that it can develop intraumatic injuries which occur in more than one area anddiagnosis and commencement of a rehabilitation programshould be made in the early period. The case is presentedhere of bilateral Type 1 CRPS developing after incompletespinal cord injury and bilateral calcaneus fracture. JClin Exp Invest 2013; 4 (3: 360-363Key words: complex regional pain syndrome, calcaneusfracture, spinal cord injury

  6. Analysis of width/height ratio and gingival zenith in patients with bilateral agenesis of maxillary lateral incisor

    Directory of Open Access Journals (Sweden)

    Núbia Inocencya Pavesi Pini

    2012-10-01

    Full Text Available OBJECTIVE: The purpose of this study was to evaluate the width/length ratio and the gingival zenith (GZ, by means of dental casts and digital caliper, in patients with missing maxillary lateral incisors after treatment. METHODS: The sample was composed of 52 subjects divided into 3 groups: BRG (n = 18, patients with bilateral agenesis treated with tooth re-contouring; BIG (n = 10 patients with agenesis treated with implants and CG (n = 24, control group. The data were analyzed using Shapiro-Wilk, Spearman correlation, Wilcoxon, Kruskal-Wallis, t test and ANOVA tests (p 0.05. GZ data for the right and left sides of the smile were not considered statistically different. CONCLUSION: Although no statistical difference was found in the comparison between the groups, analysis of the descriptive values showed that group BIG showed the greatest difference in values with regard to width/length ratio. Regarding gingival zenith, BRG showed the greatest difference.OBJETIVO: o propósito desse estudo foi analisar, por meio de modelos de estudo e paquímetro digital, a proporção largura/altura e o zênite gengival (ZG em pacientes com agenesia bilateral do incisivo lateral superior após o tratamento. MÉTODOS: a amostra consistiu de 52 voluntários divididos em 3 grupos: GBR (n=18, pacientes com agenesia bilateral tratados com reanatomizações dentárias; GBI (n=10, pacientes com agenesia bilateral tratados com implantes; e GC (n=24, grupo controle. Os dados foram avaliados por meio dos testes de Shapiro-Wilk, Wilcoxon, Kruskal-Wallis, teste t, ANOVA (p0,05. Os valores obtidos para os lados direito e esquerdo foram considerados iguais dentro de cada grupo. CONCLUSÃO: embora não tenham sido encontradas diferenças estatísticas na comparação entre os grupos, pela análise descritiva dos dados, o GBI foi o grupo que apresentou as medidas mais destoantes dos demais em relação à proporção largura/altura, sendo que, para o zênite gengival, a maior

  7. Digital image analysis of X-ray television with an image digitizer

    International Nuclear Information System (INIS)

    Mochizuki, Yasuo; Akaike, Hisahiko; Ogawa, Hitoshi; Kyuma, Yukishige

    1995-01-01

    When video signals of X-ray fluoroscopy were transformed from analog-to-digital ones with an image digitizer, their digital characteristic curves, pre-sampling MTF's and digital Wiener spectral could be measured. This method was advant ageous in that it was able to carry out data sampling because the pixel values inputted could be verified on a CRT. The system of image analysis by this method is inexpensive and effective in evaluating the image quality of digital system. Also, it is expected that this method can be used as a tool for learning the measurement techniques and physical characteristics of digital image quality effectively. (author)

  8. Chirped pulse digital holography for measuring the sequence of ultrafast optical wavefronts

    Science.gov (United States)

    Karasawa, Naoki

    2018-04-01

    Optical setups for measuring the sequence of ultrafast optical wavefronts using a chirped pulse as a reference wave in digital holography are proposed and analyzed. In this method, multiple ultrafast object pulses are used to probe the temporal evolution of ultrafast phenomena and they are interfered with a chirped reference wave to record a digital hologram. Wavefronts at different times can be reconstructed separately from the recorded hologram when the reference pulse can be treated as a quasi-monochromatic wave during the pulse width of each object pulse. The feasibility of this method is demonstrated by numerical simulation.

  9. [Comparison of body temperatures in children measured using 3 different thermometers: tympanic, skin and digital axillary].

    Science.gov (United States)

    Padilla-Raygoza, Nicolás; Ruiz-Paloalto, M Laura; Díaz-Guerrero, Rosalina; Olvera-Villanueva, Georgina; Maldonado, Angélica; Raygoza-Mendoza, María Del Pilar

    2014-01-01

    To compare body temperature measurements using tympanic, skin and digital axillary thermometers. Hospitalized or outpatient children from the General Hospital Celaya, ISSSTE Hospital Clinic and General Hospital No. 4 IMSS, and the pediatric private service in Celaya, Guanajuato, from 1 day of life until 16 years old, were recruited over a one month period, after their parents signed the consent form. The order of each institution was selected by simple randomization. Body temperatures were measured in triplicate using tympanic, skin and digital axillary thermometers. The sample consisted of 554 children. The Pearson r between the tympanic and digital axillary thermometers was 0.57 to 0.65, with a positive linear relationship (P<.05); between the skin and the digital axillary thermometers, it was between 0.47 and 0.52 with a positive linearrelationship (P<.05). The intra-observer Kappa for the tympanic thermometer was 0.86, and for the inter-observer was 0.77; for the skin thermometer it was 0.82 and 0.67, respectively, and for the digital axillary thermometer it was 0.86 for intra-observer reliability and 0.78 for inter -observer reliability. Tympanic and axillary thermometers showed better precision in measuring the body temperature in children than skin thermometers. Copyright © 2013 Elsevier España, S.L. All rights reserved.

  10. Bilateral Dorsal Subluxation of the Proximal Interphalangeal Joint of the Hind Limb in a Mare: Case Report

    OpenAIRE

    Pizzigatti, Dietrich; Hussni, Carlos Alberto; Rodrigues, Celso Antonio; Watanabe, Marcos Jun; Moura Alonso, Juliana de; Vulcano, Luiz Carlos; Cisneros Álvarez, Luis Emiliano

    2013-01-01

    Subluxation of the proximal interphalangeal joint is a rare and little studied condition in horses. We describe the case of a 12-year-old mare with bilateral dorsal subluxation of the proximal interphalangeal joint of the hind feet. Tenectomy of the medial digital flexor was performed in both limbs, and the patient showed signs of recovery within 14 days. Goniometry of the proximal interphalangeal joints 10 months after surgery showed diminution of 5° for the proximal interphalangeal axis of ...

  11. Bilateral Facial Paralysis Caused by Bilateral Temporal Bone Fracture: A Case Report and a Literature Review

    Directory of Open Access Journals (Sweden)

    Sultan Şevik Eliçora

    2015-01-01

    Full Text Available Bilateral facial paralysis caused by bilateral temporal bone fracture is a rare clinical entity, with seven cases reported in the literature to date. In this paper, we describe a 40-year-old male patient with bilateral facial paralysis and hearing loss that developed after an occupational accident. On physical examination, House-Brackmann (HB facial paralysis of grade 6 was observed on the right side and HB grade 5 paralysis on the left. Upon temporal bone computed tomography (CT examination, a fracture line exhibiting transverse progression was observed in both petrous temporal bones. Our patient underwent transmastoid facial decompression surgery of the right ear. The patient refused a left-side operation. Such patients require extensive monitoring in intensive care units because the presence of multiple injuries means that facial functions are often very difficult to evaluate. Therefore, delays may ensue in both diagnosis and treatment of bilateral facial paralysis.

  12. Bilateral optic neuropathy in acute cryptococcal meningitis

    Institute of Scientific and Technical Information of China (English)

    Qi Zhe Ngoo; Li Min Evelyn Tai; Wan Hazabbah Wan Hitam; John Tharakan

    2016-01-01

    We reported a case of cryptococcal meningitis presenting with bilateral optic neuropathy in an immunocompetent patient. A 64-year-old Malay gentleman with no medical comorbidities presented with acute bilateral blurring of vision for a week, which was associated with generalised throbbing headache and low grade fever. He also had som-nolence and altered consciousness. Visual acuity in both eyes was no perception of light with poor pupillary reflexes. Extraocular muscle movements were normal. Anterior segments were unremarkable bilaterally. Fundoscopy revealed bilateral optic disc swelling. CT scan of the brain showed multifocal infarct, but no meningeal enhancement or mass. Cerebrospinal fluid opening pressure was normal, while its culture grew Cryptococcus neoformans. A diagnosis of cryptococcal meningitis with bilateral optic neuropathy was made. Patient was treated with a six-week course of intravenous flu-conazole and started concomitantly on a fortnight's course of intravenous amphotericin B. After that, his general condition improved, but there was still no improvement in his visual acuity. On reviewing at two months post-initiation of treatment, fundi showed bilateral optic atrophy. Bilateral optic neuropathy secondary to cryptococcal meningitis was rare. The prognosis was guarded due to the sequelae of optic atrophy. Anti-fungal medication alone may not be sufficient to manage this condition. However, evidence for other treatment modalities is still lacking and further clinical studies are required.

  13. Bilateral renal calculi

    Science.gov (United States)

    Sreenevasan, G

    1974-01-01

    Bilateral renal calculi were present in 114 (10.7%) of 1,070 cases of proved urinary calculus admitted to the Urological Department of the General Hospital, Kuala Lumpur, during the period November 1968—May 1973. The management of bilateral renal calculi is discussed with reference to the first 100 cases in this series. The introduction of renography has greatly facilitated the decision as to which kidney should be operated on first. The management of patients with and without uraemia is discussed and the use of the modified V and V—Y incisions for the removal of staghorn calculi is described. Complications and results are briefly reviewed. ImagesFig. 1Fig. 4Fig. 6Fig. 7 PMID:4845653

  14. FLOWING BILATERAL FILTER: DEFINITION AND IMPLEMENTATIONS

    Directory of Open Access Journals (Sweden)

    Maxime Moreaud

    2015-06-01

    Full Text Available The bilateral filter plays a key role in image processing applications due to its intuitive parameterization and its high quality filter result, smoothing homogeneous regions while preserving the edges of the objects. Considering the image as a topological relief, seeing pixel intensities as peaks and valleys, we introduce a way to control the tonal weighting coefficients, the flowing bilateral filter, reducing "halo" artifacts typically produced by the regular bilateral filter around a large peak surrounded by two valleys of lower values. In this paper we propose to investigate exact and approximated versions of CPU and parallel GPU (Graphical Processing Unit based implementations of the regular and flowing bilateral filter using the NVidia CUDA API. Fast implementations of these filters are important for the processing of large 3D volumes up to several GB acquired by x-ray or electron tomography.

  15. Bilateral ovarian fibroma associated with Gorlin syndrome

    Directory of Open Access Journals (Sweden)

    Shahnaz Aram

    2009-02-01

    Full Text Available

    • Gorlin syndrome (GS, also known as nevoid basal cell carcinoma syndrome (NBCCS, is a rare inherited multisystem disorder. This paper presents a 22-years-old Iranian woman with this syndrome whose past history was multiple keratocysts of maxillary bone. She was referred to gynecology clinic with the chief complaint of irregular menses and vaginal spotting. On examination, frontal bossing and hypertelorism were detected. Physical examination of genitalia disclosed bilateral adnexal masses. Pelvic ultrasound showed two solid, echogenous and calcified masses measuring 100*50*10 & 60*50*45 mm in the left and right ovaries, respectively. The patient underwent right oophorectomy and ovarian mass resection with preservation of intact ovarian tissue on the left side. On frozen and permanent histological sections, bilateral and calcified ovarian fibromas were diagnosed. Surprisingly, during the last follow-up one year after the surgery, we found that our patient was expecting a baby. It can be concluded that in the presence of bilateral and calcified ovarian fibromas, the possibility of GS should be considered. Accurate diagnosis is only possible with close attention to the familial and past medical history and physical examination. In these patients, careful follow up for detecting malignancies and other complications is highly recommended.
    • KEY WORDS: Gorlin syndrome, ovarian fibroma, multiple keratocysts.

  16. Fast charge digitizer and digital data acquisition system for measuring time varying radiation fields

    International Nuclear Information System (INIS)

    Lee, T.R.; Schneider, R.H.; Wyatt, J.L.

    1976-01-01

    A radiation measuring instrument including a fast charge digitizer and a digital data acquisition system has been developed. The fast charge digitizer includes a charge integrator connected to a conventional ionization chamber which generates an output current in proportion to ionizing radiation exposure rate. The charge integrator has an output connected to a comparator which is switched from a high state to a low state when the output of the integrator goes above the comparator threshold. The comparator output is connected to a bistable multivibrator consisting of two non-retriggerable one shot multivibrators connected in a feedback configuration. As long as the comparator output is in the low state, the bistable multivibrator generates a train of pluses which are fed back through an analog switch and a high megohm resistance to the input of the integrator. This feedback is negative and has the effect of removing the charge from the integrating capacitor, thus causing the integrator output eventually to drop below the comparator threshold. When this occurs the comparator output returns to the high state and the bistable multivibrator ceases to generate output pulses. An output terminal is connected between the bistable multivibrator and the analog switch and feeds a train of pulses proportional to the amount of charge generated by the multivibrator output voltage and the high megohm resistance to a counter connected to a random access memory device. The output pulses are counted for a predetermined time and then stored in one of the data locations of the random access memory device. The counter is then reset and a further predetermined sample period is counted. This continues until all of the locations in the random access memory device are filled and then the data is read from the random access memory device

  17. Bilateral cochlear implantation: current concepts, indications, and results.

    Science.gov (United States)

    Basura, Gregory J; Eapen, Rose; Buchman, Craig A

    2009-12-01

    The optimal treatment for bilateral hearing loss continues to evolve as cochlear implant (CI) and hearing aid technologies advance, as does our understanding of the central auditory system. Ongoing discussions continue on the validity and feasibility of bilateral CI in terms of performance, justification of need, medical/surgical safety concerns, and economics. The purpose of this review article is to provide an update on the advantages and disadvantages of bilateral CI and to provide a discussion on timing (simultaneous vs. sequential), technology (bimodal vs. binaural) and feasibility. Binaural advantages are found in both adult and pediatric bilateral CI recipients, the greatest being the head shadow effect and improvements in localization and loudness summation. This theoretically offers an advantage over their unilateral implanted counterparts in terms of improved sound localization and enhanced speech perception under noisy conditions. Most investigators agree that bilateral stimulation during critical periods of development is paramount for optimizing auditory functioning in children. Currently, bilateral CI is widely accepted as a safe and effective means of bilateral auditory stimulation.

  18. A Review of Surface Deformation and Strain Measurement Using Two-Dimensional Digital Image Correlation

    Directory of Open Access Journals (Sweden)

    Khoo Sze-Wei

    2016-09-01

    Full Text Available Among the full-field optical measurement methods, the Digital Image Correlation (DIC is one of the techniques which has been given particular attention. Technically, the DIC technique refers to a non-contact strain measurement method that mathematically compares the grey intensity changes of the images captured at two different states: before and after deformation. The measurement can be performed by numerically calculating the displacement of speckles which are deposited on the top of object’s surface. In this paper, the Two-Dimensional Digital Image Correlation (2D-DIC is presented and its fundamental concepts are discussed. Next, the development of the 2D-DIC algorithms in the past 33 years is reviewed systematically. The improvement of 2DDIC algorithms is presented with respect to two distinct aspects: their computation efficiency and measurement accuracy. Furthermore, analysis of the 2D-DIC accuracy is included, followed by a review of the DIC applications for two-dimensional measurements.

  19. The effects of virtual reality-based bilateral arm training on hemiplegic children's upper limb motor skills.

    Science.gov (United States)

    Do, Ji-Hye; Yoo, Eun-Young; Jung, Min-Ye; Park, Hae Yean

    2016-01-01

    Hemiplegic cerebral palsy is a neurological symptom appearing on the unilateral arm and leg of the body that causes affected upper/lower limb muscle weakening and dysesthesia and accompanies tetany and difficulties in postural control due to abnormal muscle tone, and difficulties in body coordination. The purpose of this study was to examine the impact of virtual reality-based bilateral arm training on the motor skills of children with hemiplegic cerebral palsy, in terms of their upper limb motor skills on the affected side, as well as their bilateral coordination ability. The research subjects were three children who were diagnosed with hemiplegic cerebral palsy. The research followed an ABA design, which was a single-subject experimental design. The procedure consisted of a total of 20 sessions, including four during the baseline period (A1), 12 during the intervention period (B), and four during the baseline regression period (A2), For the independent variable bilateral arm training based on virtual reality, Nintendo Wii game was played for 30 minutes in each of the 12 sessions. For the dependent variables of upper limb motor skills on the affected side and bilateral coordination ability, a Wolf Motor Function Test (WMFT) was carried out for each session and the Pediatric Motor Activity Log (PMAL) was measured before and after the intervention, as well as after the baseline regression period. To test bilateral coordination ability, shooting baskets in basketball with both hands and moving large light boxes were carried out under operational definitions, with the number of shots and time needed to move boxes measured. The results were presented using visual graphs and bar graphs. The study's results indicated that after virtual reality-based bilateral arm training, improvement occurred in upper limb motor skills on the affected sides, and in bilateral coordination ability, for all of the research subjects. Measurements of the effects of sustained therapy after

  20. Achondroplasia Associated with Bilateral Keratoconus

    Directory of Open Access Journals (Sweden)

    Ammar M. Al Mahmood

    2012-01-01

    Full Text Available We report a rare case of bilateral keratoconus in association with achondroplasia. A 26-year-old male, with a known case of achondroplasia, complained of bilateral gradual deterioration in vision for the past few years. Slit lamp biomicroscopy showed bilateral central corneal protrusion and stromal thinning at the apex consistent with keratoconus. a trial of hard contact lens fitting failed to improve VA in the left eye (LE. Right eye (RE improved to 20/25. The patient underwent penetrating keratoplasty (PKP in his LE. Twenty-seven months postoperatively, uncorrected visual acuity (UCVA was 20/30. Ophthalmologists should be aware that patients with achondroplasia who complain of poor vision should be suspected of having keratoconus once other more common conditions are ruled out.

  1. Bilateral Complex Regional Pain Syndrome after Fracture of Bilateral Tibia and Fibula

    Directory of Open Access Journals (Sweden)

    Senem Şaş

    2017-04-01

    Full Text Available Complex regional syndrome type 1 (CRPS-1 is a painful clinical condition. It occurs after a painful event and characterized by allodynia, hyperalgesia, edema, abnormalities in skin blood flow and abnormal sudomotor activity. When CRPS-1 is associated with nerve injury, it is defined as CRPS-2. Central and peripheral theory are responsible in etiopathogenesis of CRPS-1. Generally it occurs in the injured limb. But, it may ocur in the opposite extremities. In this article, we present a case developing bilateral CRPS-1 after bilateral tibia and fibula fracture by reviewing current literatüre.

  2. Measuring the nanomechanical properties of cancer cells by digital pulsed force mode imaging

    International Nuclear Information System (INIS)

    Marti, Othmar; Holzwarth, Michael; Beil, Michael

    2008-01-01

    In this paper, we demonstrate that the digital pulsed force mode data can distinguish two cancer cell lines (HeLa, Panc) by their mechanical properties. The live cells were imaged in buffer solution. The digital pulsed force mode measured 175 force-distance curves per second which, due to the speed of the measurement, were distorted by the viscous drag in the buffer. We show that this drag force causes a sinusoidal addition to the force-distance curves. By subtracting the viscous drag effect one obtains standard force-distance curves. The force-distance curves are then evaluated to extract key data on the curves, such as adhesion energies, local stiffness or the width of the hysteresis loop. These data are then correlated to classify the force-distance curves. We show examples based on the width of the hysteresis loop and the adhesion energies. Outliers in this classification scheme are points where, potentially, interesting new physics or different physics might happen. Based on classification schemes adapted to experimental settings, we propose that the digital pulsed force mode is a tool to evaluate the time evolution of the mechanical response of cells

  3. Measuring the nanomechanical properties of cancer cells by digital pulsed force mode imaging

    Energy Technology Data Exchange (ETDEWEB)

    Marti, Othmar; Holzwarth, Michael [Institute of Experimental Physics, Ulm University, D-89069 Ulm (Germany); Beil, Michael [Department of Internal Medicine, Ulm University, D-89069 Ulm (Germany)], E-mail: othmar.marti@uni-ulm.de, E-mail: michael.holzwarth@uni-ulm.de, E-mail: michael.beil@uni-ulm.de

    2008-09-24

    In this paper, we demonstrate that the digital pulsed force mode data can distinguish two cancer cell lines (HeLa, Panc) by their mechanical properties. The live cells were imaged in buffer solution. The digital pulsed force mode measured 175 force-distance curves per second which, due to the speed of the measurement, were distorted by the viscous drag in the buffer. We show that this drag force causes a sinusoidal addition to the force-distance curves. By subtracting the viscous drag effect one obtains standard force-distance curves. The force-distance curves are then evaluated to extract key data on the curves, such as adhesion energies, local stiffness or the width of the hysteresis loop. These data are then correlated to classify the force-distance curves. We show examples based on the width of the hysteresis loop and the adhesion energies. Outliers in this classification scheme are points where, potentially, interesting new physics or different physics might happen. Based on classification schemes adapted to experimental settings, we propose that the digital pulsed force mode is a tool to evaluate the time evolution of the mechanical response of cells.

  4. A digital approach for real time high-rate high-resolution radiation measurements

    International Nuclear Information System (INIS)

    Gerardi, G.; Abbene, L.

    2014-01-01

    Modern spectrometers are currently developed by using digital pulse processing (DPP) systems, showing several advantages over traditional analog electronics. The aim of this work is to present digital strategies, in a time domain, for the development of real time high-rate high-resolution spectrometers. We propose a digital method, based on the single delay line (SDL) shaping technique, able to perform multi-parameter analysis with high performance even at high photon counting rates. A robust pulse shape and height analysis (PSHA), applied on single isolated time windows of the detector output waveforms, is presented. The potentialities of the proposed strategy are highlighted through both theoretical and experimental approaches. To strengthen our approach, the implementation of the method on a real-time system together with some experimental results are presented. X-ray spectra measurements with a semiconductor detector are performed both at low and high photon counting rates (up to 1.1 Mcps)

  5. A digital approach for real time high-rate high-resolution radiation measurements

    Energy Technology Data Exchange (ETDEWEB)

    Gerardi, G.; Abbene, L., E-mail: leonardo.abbene@unipa.it

    2014-12-21

    Modern spectrometers are currently developed by using digital pulse processing (DPP) systems, showing several advantages over traditional analog electronics. The aim of this work is to present digital strategies, in a time domain, for the development of real time high-rate high-resolution spectrometers. We propose a digital method, based on the single delay line (SDL) shaping technique, able to perform multi-parameter analysis with high performance even at high photon counting rates. A robust pulse shape and height analysis (PSHA), applied on single isolated time windows of the detector output waveforms, is presented. The potentialities of the proposed strategy are highlighted through both theoretical and experimental approaches. To strengthen our approach, the implementation of the method on a real-time system together with some experimental results are presented. X-ray spectra measurements with a semiconductor detector are performed both at low and high photon counting rates (up to 1.1 Mcps)

  6. Measurement of curvature and twist of a deformed object using digital holography

    International Nuclear Information System (INIS)

    Chen Wen; Quan Chenggen; Cho Jui Tay

    2008-01-01

    Measurement of curvature and twist is an important aspect in the study of object deformation. In recent years, several methods have been proposed to determine curvature and twist of a deformed object using digital shearography. Here we propose a novel method to determine the curvature and twist of a deformed object using digital holography and a complex phasor. A sine/cosine transformation method and two-dimensional short time Fourier transform are proposed subsequently to process the wrapped phase maps. It is shown that high-quality phase maps corresponding to curvature and twist can be obtained. An experiment is conducted to demonstrate the validity of the proposed method

  7. Bilateral tension pneumothorax after acupuncture.

    Science.gov (United States)

    Mohammad, Nurashikin

    2018-04-19

    Acupuncture is an ancient complementary medicine which is currently used worldwide. Many serious adverse events have been reported which include a spectrum of mild-to-fatal complications. However, the level of awareness with regard to complications is still low both to physicians and patients. We report a 63-year-old who presented with acute shortness of breath 2 hours after having had acupuncture. On examination, there was absent breath sound heard on the left lung and slightly reduced breath sound on the right lung. She had type 1 respiratory failure. Urgent chest radiograph confirmed bilateral pneumothorax which was more severe on the left with tension pneumothorax and mediastinal shift. Chest tubes were inserted bilaterally after failed needle aspiration attempts. Subsequently, the pneumothoraces resolved, and she was discharged well. The bilateral pneumothoraces caused by acupuncture were curable but could have been potentially fatal if diagnosis was delayed. This case report adds to the limited current literature on the complications of acupuncture leading to bilateral pneumothoraces. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  8. Hydraulic bilateral construction robot; Yuatsushiki bilateral kensetsu robot

    Energy Technology Data Exchange (ETDEWEB)

    Maehata, K.; Mori, N. [Kayaba Industry Co. Ltd., Tokyo (Japan)

    1999-05-15

    Concerning a hydraulic bilateral construction robot, its system constitution, structures and functions of important components, and the results of some tests are explained, and the researches conducted at Gifu University are described. The construction robot in this report is a servo controlled system of a version developed from the mini-shovel now available in the market. It is equipped, in addition to an electrohydraulic servo control system, with various sensors for detecting the robot attitude, vibration, and load state, and with a camera for visualizing the surrounding landscape. It is also provided with a bilateral joy stick which is a remote control actuator capable of working sensation feedback and with a rocking unit that creates robot movements of rolling, pitching, and heaving. The construction robot discussed here, with output increased and response faster thanks to the employment of a hydraulic driving system for the aim of building a robot system superior in performance to the conventional model designed primarily for heavy duty, proves after tests to be a highly sophisticated remotely controlled robot control system. (NEDO)

  9. Bilateral pallidotomy for generalized dystonia Palidotomia bilateral para distonias generalizadas

    Directory of Open Access Journals (Sweden)

    Hélio A. G. Teive

    2001-06-01

    Full Text Available OBJECTIVE: To evaluate the efficacy and safety of bilateral pallidotomies in five patients with generalized dystonia. BACKGROUND: Generalized dystonias are frequently a therapeutic challenge, with poor responses to pharmacological treatment. GPi (globus pallidus internus pallidotomies for Parkinson's disease ameliorate all kinds of dyskinesias/dystonia, and recent studies reported a marked improvement of refractory dystonias with this procedure. METHODS: Five patients with generalized dystonias refractory to medical treatment were selected; one posttraumatic and four idiopathic. The decision to perform bilateral procedures was based on the predominant axial involvement in these patients. Dystonia severity was assessed with the Burke-Fahn-Marsden Dystonia Scale (BFM. Simultaneous procedures were performed in all but one patient, who had a staged procedure. They were reevaluated with the same scale (BFM by an unblinded rater at 1, 2, 3, 30, 60, 90, 120 and 180 days post-operatively. RESULTS: The four patients with idiopathic dystonia showed a progressive improvement up to three months; the patient with posttraumatic dystonia relapsed at three months. One patient had a marked improvement, being able to discontinue all the medications. A mean decrease in the BFM scores of 52,58% was noted. One patient had a trans-operative motor seizure followed by a transient hemiparesis secondary to rack hemorrhage; other was lethargic up to three days after the procedure. CONCLUSIONS: Our results show that bilateral GPi pallidotomies may be a safe and effective approach to medically refractory generalized dystonias; it can also be speculated that the posttraumatic subgroup may not benefit with this procedure.As distonias generalizadas são freqüentemente um desafio terapêutico, com pobres respostas aos tratamentos farmacológicos. As cirurgias estereotáxicas, como a palidotomia, têm sido utilizadas com êxito no tratamento da doença de Parkinson e estudos

  10. Simultaneous bilateral elbow dislocation with bilateral medial epicondyle fractures in a 13-year-old female gymnast with hyperlaxity

    Science.gov (United States)

    Bauer, Stefan; Dunne, Ben; Whitewood, Colin

    2012-01-01

    Bilateral simultaneous elbow dislocations are extremely rare and have only been described in 12 cases. In the paediatric population unilateral elbow dislocations are rare with 3–6% of all elbow injuries and there are only few studies describing this injury exclusively in children. There is only one case report of a paediatric patient who sustained a simultaneous bilateral elbow dislocation with medial epicondyle fractures. We present a second paediatric case of simultaneous bilateral elbow dislocation with associated displaced bilateral medial epicondyle fractures in a gymnast with joint hyperlaxity (3 of 5 Wynne-Davies criteria) treated with closed reduction and short-term immobilisation (3 weeks). The patient returned to full trampoline gymnastics between 4 and 5 months postinjury and made an uneventful recovery. PMID:23234820

  11. Effect of acute bilateral adrenalectomy and reserpine on gastric ...

    African Journals Online (AJOL)

    STORAGESEVER

    2008-09-03

    Sep 3, 2008 ... the secretion of gastric mucus in a system where glycoprotein erosion is measured together with adherent mucus secretion in the gastric mucosa in the unstimu- lated state. Therefore, the present study was undertaken to examine the effect of acute bilateral adrenalectomy and dopamine depletory agent ...

  12. THE EUROPEAN UNION’S BILATERAL APPROACH

    Directory of Open Access Journals (Sweden)

    Ludmila BORTA

    2014-12-01

    Full Text Available The EU is a world economic power and a major trading partner for most countries. All the time, this region has been interested and has acted towards a free and fair trade. The decrease and even the elimination of tariff and non-tariff barriers in the world trade are among the main objectives of the EU strategy for international trade. At the moment, the elusive outcome of the WTO Doha Round has led to the proliferation of bilateral trade agreements worldwide. Although the EU remains committed to further development of the multilateral trading system, however, the EU still has appealed also to the development of bilateral trade relations. The aim of this paper is to illustrate the current bilateral dimension of the common commercial policy of the EU. In conclusion, to describe this bilateral approach of the EU we are using one word, namely “diversity”.

  13. A case of bilateral tubal pregnancy

    Directory of Open Access Journals (Sweden)

    Ayano Funamizu

    2017-11-01

    Full Text Available Bilateral tubal pregnancy is very rare and occurs in only 1 out of every 200,000 spontaneous pregnancies. In this case, a 29-year-old woman with a history of primary infertility underwent treatment with human menopausal gonadotropin (hMG-human chorionic gonadotropin (hCG, and became pregnant. A gestational sac (GS was not detected in the uterus and transvaginal ultrasonography (USG revealed GS with fetal heartbeat in the left adnexa at 7 weeks and 6 days of gestation. The patient underwent laparoscopic surgery and ultimately, bilateral tubal pregnancy was diagnosed. Consequently, bilateral fallopian tube resection was performed. Afterwards, she conceived by assisted reproductive technology (ART and delivered vaginally. This case suggests that even if a GS is found in one fallopian tube by USG, it is important to evaluate the other fallopian tube carefully. Keywords: bilateral tubal pregnancy, ectopic pregnancy, human menopausal gonadotropin, laparoscopy

  14. Development of digital power measuring and protecting equipment for SPRR-300 reactor

    International Nuclear Information System (INIS)

    Wang Xuejie; Li Xi'an; Zhu Shilei

    2005-01-01

    A measuring and protecting equipment of reactor power based on Single-Chip Microcomputer is introduced in this paper. The composition of hardware and the major control idea about the software for the equipment are presented. Digitizing the measuring data from nuclear instruments is precondition of reactor control and protection system which would be computerizing, and it is also an application of redundancy and variety of reactor protection system in nuclear measuring instruments. At last the working state is described. (authors)

  15. Review: Michael Crandall & Karen E. Fisher (Eds) Digital Inclusion: Measuring the Impact of Information and Community Technology

    DEFF Research Database (Denmark)

    Pors, Niels Ole

    2010-01-01

    Review: Michael Crandall & Karen E. Fisher (Eds) Digital Inclusion: Measuring the Impact of Information and Community Technology. Medford. Information Today. ASIS&T Monographs, 2009. 185 pages. $ 59.50. ISBN 978-1-57387-373-4......Review: Michael Crandall & Karen E. Fisher (Eds) Digital Inclusion: Measuring the Impact of Information and Community Technology. Medford. Information Today. ASIS&T Monographs, 2009. 185 pages. $ 59.50. ISBN 978-1-57387-373-4...

  16. Analysis of electrically evoked compound action potential of the auditory nerve in children with bilateral cochlear implants.

    Science.gov (United States)

    Caldas, Fernanda Ferreira; Cardoso, Carolina Costa; Barreto, Monique Antunes de Souza Chelminski; Teixeira, Marina Santos; Hilgenberg, Anacléia Melo da Silva; Serra, Lucieny Silva Martins; Bahmad Junior, Fayez

    2016-01-01

    The cochlear implant device has the capacity to measure the electrically evoked compound action potential of the auditory nerve. The neural response telemetry is used in order to measure the electrically evoked compound action potential of the auditory nerve. To analyze the electrically evoked compound action potential, through the neural response telemetry, in children with bilateral cochlear implants. This is an analytical, prospective, longitudinal, historical cohort study. Six children, aged 1-4 years, with bilateral cochlear implant were assessed at five different intervals during their first year of cochlear implant use. There were significant differences in follow-up time (p=0.0082) and electrode position (p=0.0019) in the T-NRT measure. There was a significant difference in the interaction between time of follow-up and electrode position (p=0.0143) when measuring the N1-P1 wave amplitude between the three electrodes at each time of follow-up. The electrically evoked compound action potential measurement using neural response telemetry in children with bilateral cochlear implants during the first year of follow-up was effective in demonstrating the synchronized bilateral development of the peripheral auditory pathways in the studied population. Copyright © 2015 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  17. Digital Moiré based transient interferometry and its application in optical surface measurement

    Science.gov (United States)

    Hao, Qun; Tan, Yifeng; Wang, Shaopu; Hu, Yao

    2017-10-01

    Digital Moiré based transient interferometry (DMTI) is an effective non-contact testing methods for optical surfaces. In DMTI system, only one frame of real interferogram is experimentally captured for the transient measurement of the surface under test (SUT). When combined with partial compensation interferometry (PCI), DMTI is especially appropriate for the measurement of aspheres with large apertures, large asphericity or different surface parameters. Residual wavefront is allowed in PCI, so the same partial compensator can be applied to the detection of multiple SUTs. Excessive residual wavefront aberration results in spectrum aliasing, and the dynamic range of DMTI is limited. In order to solve this problem, a method based on wavelet transform is proposed to extract phase from the fringe pattern with spectrum aliasing. Results of simulation demonstrate the validity of this method. The dynamic range of Digital Moiré technology is effectively expanded, which makes DMTI prospective in surface figure error measurement for intelligent fabrication of aspheric surfaces.

  18. Bilateral sarkoidose i glandula parotis

    DEFF Research Database (Denmark)

    Hahn, Pernille; Krogdahl, Annelise; Godballe, Christian

    2012-01-01

    We describe an unusual case of sarcoidosis in which the patient presented with a bilateral swelling of the parotid salivary glands and no other manifestation of the disease. Sarcoidosis is a multisystem granulomatous disorder of unknown cause in which there may be multiple exocrine involvement......, including the salivary glands. This case emphasises the importance of including sarcoidosis in the differential diagnosis of bilateral parotid swelling....

  19. Development of Gravity Acceleration Measurement Using Simple Harmonic Motion Pendulum Method Based on Digital Technology and Photogate Sensor

    Science.gov (United States)

    Yulkifli; Afandi, Zurian; Yohandri

    2018-04-01

    Development of gravitation acceleration measurement using simple harmonic motion pendulum method, digital technology and photogate sensor has been done. Digital technology is more practical and optimizes the time of experimentation. The pendulum method is a method of calculating the acceleration of gravity using a solid ball that connected to a rope attached to a stative pole. The pendulum is swung at a small angle resulted a simple harmonic motion. The measurement system consists of a power supply, Photogate sensors, Arduino pro mini and seven segments. The Arduino pro mini receives digital data from the photogate sensor and processes the digital data into the timing data of the pendulum oscillation. The calculation result of the pendulum oscillation time is displayed on seven segments. Based on measured data, the accuracy and precision of the experiment system are 98.76% and 99.81%, respectively. Based on experiment data, the system can be operated in physics experiment especially in determination of the gravity acceleration.

  20. MODERN VIEWS ON BILATERAL BREAST CANCER

    Directory of Open Access Journals (Sweden)

    Ye. A. Fesik

    2014-01-01

    Full Text Available Presented modern literature data on the features of the pathogenesis, course, clinical and morphological expression and tumor characteristics, parameters and nodal metastasis of hematogenous bilateral breast cancer. Highlight the results of domestic and foreign studies in recent years to determine the prognostic factors and recurrence of synchronous and metachronous bilateral breast cancer. It was revealed that the frequency of bilateral breast tumor lesions varies widely, ranging from 0.1 to 20%, with metachronous tumors recorded significantly higher (69.6% than the synchronous (22.7%. The probability of occurrence of metachronous breast cancer is higher in women with a family history, as well as if they have a gene mutation BRCA-1. Found that the most common histological type of breast tumor with bilateral lesions is invasive ductal. However, the incidence of invasive lobular cancer and non-invasive lobular cancer is slightly higher among synchronous bilateral cancer compared with unilateral disease. Studies have shown that in a double-sided synchronous breast cancer tumor, as a rule, has a lower degree of differentiation, and the higher the expression level of estrogen receptors and progesterone receptors. Relevance of the issue because the identification of patterns in the study of lymphatic and hematogenous features bilateral metastasis of mammary tumors provides a basis for speculation about the differences in the progression of neoplastic disease in these groups and is a cause for further detailed research in this area to identify and evaluate the prognosis and also the choice of tactics of such patients.

  1. Bilateral renal cell carcinoma in a horseshoe kidney: preoperative assessment with MRI and digital subtraction angiography

    International Nuclear Information System (INIS)

    Schubert, R.A.; Soeldner, J.; Kaiser, W.A.; Steiner, T.; Schubert, J.

    1998-01-01

    Renal cell carcinoma in a horseshoe kidney is an unusual entity. To our knowledge, only 123 cases have been published to date. We report the first bilateral case of two clear-cell carcinomas in an asymmetrically fused kidney. Optimum preservation of renal function after radical tumor removal requires accurate preoperative imaging. Since the vascular supply in fusion anomalies is extremely variable, angiography is mandatory. Magnetic resonance imaging was most suitable to predict the tumor extent and localization, because it simultaneously gave the most comprehensive anatomical overview of the malformation. (orig.)

  2. Automated digital volume measurement of melanoma metastases in sentinel nodes predicts disease recurrence and survival

    DEFF Research Database (Denmark)

    Riber-Hansen, Rikke; Nyengaard, Jens R; Hamilton-Dutoit, Stephen J

    2011-01-01

    statistics (categorical data). In addition, disease-free and melanoma-specific survivals were calculated. Mean metastatic volume per patient was 10.6 mm(3) (median 0.05 mm(3); range 0.0001-621.3 mm(3)) and 9.62 mm(3) (median 0.05 mm(3); range 0.00001-564.3 mm(3)) with manual and digital measurement......, respectively. The Bland-Altman plot showed an even distribution of the differences, and the kappa statistic was 0.84. In multivariate analysis, both manual and digital metastasis volume measurements were independent progression markers when corrected for primary tumour thickness [manual: hazard ratio (HR): 1...

  3. Bilateral coordination and gait symmetry after body-weight supported treadmill training for persons with chronic stroke.

    Science.gov (United States)

    Combs, Stephanie A; Dugan, Eric L; Ozimek, Elicia N; Curtis, Amy B

    2013-04-01

    Locomotor interventions are commonly assessed using functional outcomes, but these outcomes provide limited information about changes toward recovery or compensatory mechanisms. The study purposes were to examine changes in gait symmetry and bilateral coordination following body-weight supported treadmill training in individuals with chronic hemiparesis due to stroke and to compare findings to participants without disability. Nineteen participants with stroke (>6 months) who ambulated between 0.4 and 0.8 m/s and 22 participants without disability were enrolled in this repeated-measures study. The stroke group completed 24 intervention sessions over 8 weeks with 20 minutes of walking/session. The non-disabled group served as a comparison for describing changes in symmetry and coordination. Bilateral 3-dimensional motion analysis and gait speed were assessed across 3 time points (pre-test, immediate post-test, and 6-month retention). Continuous relative phase was used to evaluate bilateral coordination (thigh-thigh, shank-shank, foot-foot) and gait symmetry was assessed with spatiotemporal ratios (step length, swing time, stance time). Significant improvements in continuous relative phase (shank-shank and foot-foot couplings) were found at post-test and retention for the stroke group. Significant differences in spatiotemporal symmetry ratios were not found over time. Compared to the non-disabled group, changes in bilateral coordination moved in the direction of normal recovery. Most measures of continuous relative phase were more responsive to change after training than the spatiotemporal ratios. After body-weight supported treadmill training, the stroke group made improvements toward recovery of normal bilateral coordination. Bilateral coordination and gait symmetry measures may assess different aspects of gait. Copyright © 2013 Elsevier Ltd. All rights reserved.

  4. Quantitative Study of Vibrational Symmetry of Injured Vocal Folds via Digital Kymography in Excised Canine Larynges

    Science.gov (United States)

    Krausert, Christopher R.; Ying, Di; Zhang, Yu; Jiang, Jack J.

    2011-01-01

    Purpose: Digital kymography and vocal fold curve fitting are blended with detailed symmetry analysis of kymograms to provide a comprehensive characterization of the vibratory properties of injured vocal folds. Method: Vocal fold vibration of 12 excised canine larynges was recorded under uninjured, unilaterally injured, and bilaterally injured…

  5. Paresia diafragmática bilateral idiopática Idiopathic bilateral diaphragmatic paresis

    Directory of Open Access Journals (Sweden)

    Mônica Corso Pereira

    2006-10-01

    Full Text Available Relata-se o caso de um paciente com dispnéia intensa ao se deitar, em que foram excluídas doenças pulmonares, neuromusculares ou cardíacas, cuja investigação revelou paresia diafragmática bilateral. Um sinal chave para o diagnóstico foi a evidência de respiração paradoxal com o doente em decúbito supino. Havia piora da oxigenação e da capacidade vital forçada com a mudança da posição ortostática para supina. A fluoroscopia ortostática foi normal. A pressão inspiratória máxima estava muito reduzida. A estimulação elétrica transcutânea do diafragma foi normal, e a eletroestimulação do nervo frênico mostrou ausência de resposta, permitindo o diagnóstico de paresia bilateral do diafragma.We report the case of a patient with severe dyspnea upon reclining. Lung disease, neuromuscular disorders and heart disease were ruled out. However, during the course of the investigation, bilateral diaphragmatic paresis was discovered. A key sign leading to the diagnosis was evidence of paradoxical respiration in the dorsal decubitus position. When the patient was moved from the orthostatic position to the dorsal decubitus position, oxygenation and forced vital capacity worsened. The orthostatic fluoroscopy was normal. Maximal inspiratory pressure was severely reduced. The responses to transcutaneous electric stimulation of the diaphragm were normal. However, electric stimulation of the phrenic nerve produced no response, leading to the diagnosis of bilateral diaphragmatic paresis.

  6. Bilateral microperc in a severe kyphoscoliosis

    OpenAIRE

    Dağgülli, Mansur; Penbegül, Necmettin; Dede, Onur; Utanğaç, Mehmet Mazhar

    2016-01-01

    Percutaneous nephrolithotomy is the standard modality for large renal calculi in normal and abnormal renal anatomic situations. This case report describes a 57-year-old male patient who presented with bilateral kidney stones and severe kyphoscoliosis. He had successfully been treated with a bilateral microperc technique.

  7. A case of bilateral trench foot.

    Science.gov (United States)

    Parsons, S L; Leach, I H; Charnley, R M

    1993-12-01

    A case of severe bilateral trench foot is presented in a patient who lived rough for 3 weeks without removing his boots. Non-operative management yielded no clinical improvement and bilateral below-knee amputation was necessary. Histology revealed subcutaneous and muscle necrosis with secondary arterial thrombosis.

  8. LEARNING ONE-DIGIT DECIMAL NUMBERS BY MEASUREMENT AND GAME PREDICTING LENGTH

    Directory of Open Access Journals (Sweden)

    Puji Astuti

    2014-01-01

    Full Text Available This paper aims to describe how students develop understanding of one-digit decimals. To achieve the aim, Local Instruction Theory (LIT about the process of learning decimals and the means designed to support that learning are developed. Along with this idea, the framework of Realistic Mathematics Education (RME is proposed. Based on the aim, design research methodology is used. This paper discusses learning activities of three meetings from teaching experiment of the focus group students of the fourth grade elementary school in Surabaya: SDIT Al Ghilmani. The data indicated that the learning activities promoted the students’ understanding of one-digit decimal numbers.Keyword: measurement, decimal numbers, number line DOI: http://dx.doi.org/10.22342/jme.5.1.1447.35-46

  9. A rare nonsyndromic presentation of bilateral doughnut shaped lip pits in an Indian child

    Directory of Open Access Journals (Sweden)

    Senthil Balasubramani

    2016-01-01

    Full Text Available Lip pits are a rare congenital anomaly that presents on the upper or lower lip or the commissure of the lips. Lip pits are an autosomal dominant trait occurring almost always in association with cleft lip or palate. They most commonly occur in association with developmental disturbances such as Van der Woude's syndrome, popliteal pterygium syndrome, oro-facial-digital syndrome, Marres-Cremers syndrome, and Hirschsprung disease. Its occurrence in nonsyndromic individuals is extremely rare with only a handful of cases reported. The identification of lip pits with other associated anomalies is crucial for genetic counseling; we report a case of nonsyndromic presentation of bilateral lip pits.

  10. A simplified, improved method for making amplifier equivalent noise charge measurements using a new generation digitizing oscilloscope

    International Nuclear Information System (INIS)

    Zimmerman, T.

    1990-10-01

    Historically a variety of methods have been used to measure the equivalent noise charge (ENC) of amplifier/shaper systems for high energy physics. Some of these methods require several pieces of special test equipment and a fair amount of effort. The advent of digitizing oscilloscopes with statistics capabilities makes it possible to perform certain types of noise measurements accurately with very little effort. This paper describes the noise measurement method of a time invariant amplifier/shaper and of a time variant correlated sampling system, using a Tektronix DSA602 Digitizing Signal Analyzer. 4 figs

  11. Virtual instrumentation technique used in the nuclear digital signal processing system design: Energy and time measurement tests

    International Nuclear Information System (INIS)

    Pechousek, J.; Prochazka, R.; Prochazka, V.; Frydrych, J.

    2011-01-01

    In this report, computer-based digital signal processing system with a 200 MS s -1 sampling digitizer is presented. Virtual instrumentation technique is used to easily develop a system which provides spectroscopy measurements such as amplitude and time signal analysis, with the time-of-flight facility. Several test measurements were performed to determine the characteristics of a system. The presented system may find its application in the coincidence measurement since the system is usable for different types of detectors and sensitive to decay lifetimes from tens of nanoseconds to seconds.

  12. Digital Pills to Measure Opioid Ingestion Patterns in Emergency Department Patients With Acute Fracture Pain: A Pilot Study.

    Science.gov (United States)

    Chai, Peter R; Carreiro, Stephanie; Innes, Brendan J; Rosen, Rochelle K; O'Cleirigh, Conall; Mayer, Kenneth H; Boyer, Edward W

    2017-01-13

    Nonadherence to prescribed regimens for opioid analgesic agents contributes to increasing opioid abuse and overdose death. Opioids are frequently prescribed on an as-needed basis, placing the responsibility to determine opioid dose and frequency with the patient. There is wide variability in physician prescribing patterns because of the lack of data describing how patients actually use as-needed opioid analgesics. Digital pill systems have a radiofrequency emitter that directly measures medication ingestion events, and they provide an opportunity to discover the dose, timing, and duration of opioid therapy. The purpose of this study was to determine the feasibility of a novel digital pill system to measure as-needed opioid ingestion patterns in patients discharged from the emergency department (ED) after an acute bony fracture. We used a digital pill with individuals who presented to a teaching hospital ED with an acute extremity fracture. The digital pill consisted of a digital radiofrequency emitter within a standard gelatin capsule that encapsulated an oxycodone tablet. When ingested, the gastric chloride ion gradient activated the digital pill, transmitting a radiofrequency signal that was received by a hip-worn receiver, which then transmitted the ingestion data to a cloud-based server. After a brief, hands-on training session in the ED, study participants were discharged home and used the digital pill system to ingest oxycodone prescribed as needed for pain for one week. We conducted pill counts to verify digital pill data and open-ended interviews with participants at their follow-up appointment with orthopedics or at one week after enrollment in the study to determine the knowledge, attitudes, beliefs, and practices regarding digital pills. We analyzed open-ended interviews using applied thematic analysis. We recruited 10 study participants and recorded 96 ingestion events (87.3%, 96/110 accuracy). Study participants reported being able to operate all

  13. Digital temperature meter

    Energy Technology Data Exchange (ETDEWEB)

    Glowacki, S

    1982-01-01

    Digital temperature meter for precise temperature measurements is presented. Its parts such as thermostat, voltage-frequency converter and digital frequency meter are described. Its technical parameters such as temperature range 50degC-700degC, measurement precision 1degC, measurement error +-1degC are given. (A.S.).

  14. Ceratite bilateral por Acanthamoeba: relato de caso Bilateral Acanthamoeba keratitis: case report

    Directory of Open Access Journals (Sweden)

    Wilson Nahmatallah Obeid

    2003-12-01

    Full Text Available A ceratite por Acanthamoeba é uma infecção ocular grave que, apesar dos recentes progressos no diagnóstico e tratamento, ainda provoca prolongada morbidade e perda da acuidade visual. Relatamos um caso de ceratite bilateral por Acanthamoeba em usuário de lentes de contato, que é o primeiro caso descrito na literatura brasileira.Acanthamoeba keratitis is a severe ocular infection which even with recent progress in diagnosis and treatment still causes long morbidity and loss of visual acuity. We describe a case of bilateral Acanthamoeba keratitis in a user of contact lenses, which is the first case discussed in Brazilian literature.

  15. Is digital photography an accurate and precise method for measuring range of motion of the hip and knee?

    Science.gov (United States)

    Russo, Russell R; Burn, Matthew B; Ismaily, Sabir K; Gerrie, Brayden J; Han, Shuyang; Alexander, Jerry; Lenherr, Christopher; Noble, Philip C; Harris, Joshua D; McCulloch, Patrick C

    2017-09-07

    Accurate measurements of knee and hip motion are required for management of musculoskeletal pathology. The purpose of this investigation was to compare three techniques for measuring motion at the hip and knee. The authors hypothesized that digital photography would be equivalent in accuracy and show higher precision compared to the other two techniques. Using infrared motion capture analysis as the reference standard, hip flexion/abduction/internal rotation/external rotation and knee flexion/extension were measured using visual estimation, goniometry, and photography on 10 fresh frozen cadavers. These measurements were performed by three physical therapists and three orthopaedic surgeons. Accuracy was defined by the difference from the reference standard, while precision was defined by the proportion of measurements within either 5° or 10°. Analysis of variance (ANOVA), t-tests, and chi-squared tests were used. Although two statistically significant differences were found in measurement accuracy between the three techniques, neither of these differences met clinical significance (difference of 1.4° for hip abduction and 1.7° for the knee extension). Precision of measurements was significantly higher for digital photography than: (i) visual estimation for hip abduction and knee extension, and (ii) goniometry for knee extension only. There was no clinically significant difference in measurement accuracy between the three techniques for hip and knee motion. Digital photography only showed higher precision for two joint motions (hip abduction and knee extension). Overall digital photography shows equivalent accuracy and near-equivalent precision to visual estimation and goniometry.

  16. Bilateral agenesis of the anterior cruciate ligament: MRI evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Bedoya, Maria A.; Jaramillo, Diego [The Children' s Hospital of Philadelphia, Radiology Department, Philadelphia, PA (United States); McGraw, Michael H. [Hospitalof theUniversityof Pennsylvania, Divisionof Orthopaedics, Philadelphia, PA (United States); Wells, Lawrence [The Children' s Hospital of Philadelphia, Division of Orthopaedics, Philadelphia, PA (United States)

    2014-09-15

    Bilateral agenesis of the anterior cruciate ligament (ACL) is extremely rare. We describe a 13-year-old girl who presented with bilateral knee pain without history of trauma; she has two family members with knee instability. Magnetic resonance imaging showed bilateral absence of the ACL, and medial posterior horn meniscal tears. Bilateral arthroscopic partial meniscectomy and anterior cruciate ligament reconstruction was performed. (orig.)

  17. Thumbs down: a molecular-morphogenetic approach to avian digit homology.

    Science.gov (United States)

    Capek, Daniel; Metscher, Brian D; Müller, Gerd B

    2014-01-01

    Avian forelimb digit homology remains one of the standard themes in comparative biology and EvoDevo research. In order to resolve the apparent contradictions between embryological and paleontological evidence a variety of hypotheses have been presented in recent years. The proposals range from excluding birds from the dinosaur clade, to assignments of homology by different criteria, or even assuming a hexadactyl tetrapod limb ground state. At present two approaches prevail: the frame shift hypothesis and the pyramid reduction hypothesis. While the former postulates a homeotic shift of digit identities, the latter argues for a gradual bilateral reduction of phalanges and digits. Here we present a new model that integrates elements from both hypotheses with the existing experimental and fossil evidence. We start from the main feature common to both earlier concepts, the initiating ontogenetic event: reduction and loss of the anterior-most digit. It is proposed that a concerted mechanism of molecular regulation and developmental mechanics is capable of shifting the boundaries of hoxD expression in embryonic forelimb buds as well as changing the digit phenotypes. Based on a distinction between positional (topological) and compositional (phenotypic) homology criteria, we argue that the identity of the avian digits is II, III, IV, despite a partially altered phenotype. Finally, we introduce an alternative digit reduction scheme that reconciles the current fossil evidence with the presented molecular-morphogenetic model. Our approach identifies specific experiments that allow to test whether gene expression can be shifted and digit phenotypes can be altered by induced digit loss or digit gain. © 2013 Wiley Periodicals, Inc.

  18. Quality control measurements for digital x-ray detectors

    Energy Technology Data Exchange (ETDEWEB)

    Marshall, N W [Department of Radiology, University Hospitals Leuven, 49 Herenstraat, 3000 Leuven (Belgium); Mackenzie, A [National Co-ordinating Centre for the Physics of Mammography, Medical Physics, Level B, St Luke' s Wing, The Royal Surrey County Hospital NHS Trust, Egerton Road, Guildford, GU2 7XX (United Kingdom); Honey, I D, E-mail: nicholas.marshall@uz.kuleuven.ac.be [Department of Medical Physics, Floor 3, Henriette Raphael House, Guy' s and St Thomas' Hospital, London, SE1 9RT (United Kingdom)

    2011-02-21

    This paper describes a digital radiography (DR) quality control protocol for DR detectors from the forthcoming report from the Institute of Physics and Engineering in Medicine (IPEM). The protocol was applied to a group of six identical caesium iodide (CsI) digital x-ray detectors to assess reproducibility of methods, while four further detectors were assessed to examine the wider applicability. Twelve images with minimal spatial frequency processing are required, from which the detector response, lag, modulation transfer function (MTF), normalized noise power spectrum (NNPS) and threshold contrast-detail (c-d) detectability are calculated. The x-ray spectrum used was 70 kV and 1 mm added copper filtration, with a target detector air kerma of 2.5 {mu}Gy for the NNPS and c-d results. In order to compare detector performance with previous imaging technology, c-d data from four screen/film systems were also acquired, at a target optical density of 1.5 and an average detector air kerma of 2.56 {mu}Gy. The DR detector images were typically acquired in 20 min, with a further 45 min required for image transfer and analysis. The average spatial frequency for the 50% point of the MTF for six identical detectors was 1.29 mm{sup -1} {+-} 0.05 (3.9% coefficient of variation (cov)). The air kerma set for the six systems was 2.57 {mu}Gy {+-} 0.13 (5.0% cov) and the NNPS at this air kerma was 1.42 x 10{sup -5} mm{sup 2} (6.5% cov). The detective quantum efficiency (DQE) measured for the six identical detectors was 0.60 at 0.5 mm{sup -1}, with a maximum cov of 10% at 2.9 mm{sup -1}, while the average DQE was 0.56 at 0.5 mm{sup -1} for three CsI detectors from three different manufacturers. Comparable c-d performance was found for these detectors (5.9% cov) with an average threshold contrast of 0.46% for 11 mm circular discs. The average threshold contrast for the S/F systems was 0.70% at 11 mm, indicating superior imaging performance for the digital systems. The protocol was found

  19. Staged bilateral carotid endarterectomy

    DEFF Research Database (Denmark)

    Schroeder, T; Sillesen, H; Engell, Hans Christian

    1986-01-01

    In a series of 56 staged bilateral carotid endarterectomies, new neurologic symptoms developed in 5% and 20% following the first and second procedure, respectively. All complications were transient or minor. The incidence of postendarterectomy hypertension was significantly higher following...... the second procedure, when operations were staged less than 3 weeks apart. A correlation between these hypertensive episodes and the occurrence of new neurologic symptoms could not be shown. However, as this correlation has been proved in several other reports, bilateral carotid endarterectomy is advised...... to be staged at least 3 weeks apart. In addition, a conservative attitude towards contralateral asymptomatic lesions is proposed....

  20. Comparison of a digital and an optical analogue hand-held refractometer for the measurement of canine urine specific gravity.

    Science.gov (United States)

    Paris, J K; Bennett, A D; Dodkin, S J; Gunn-Moore, D A

    2012-05-05

    Urine specific gravity (USG) is used clinically as a measure of urine concentration, and is routinely assessed by refractometry. A comparison between optical analogue and digital refractometers for evaluation of canine urine has not been reported. The aim of this study was to compare a digital and an optical analogue hand-held refractometer for the measurement of canine USG, and to assess correlation with urine osmolality. Prospective study. Free-catch urine samples were collected from 285 hospitalised adult dogs, and paired USG readings were obtained with a digital and an optical analogue refractometer. In 50 dogs, urine osmolality was also measured using a freezing point depression osmometer. There was a small but statistically significant difference between the two refractometers (P<0.001), with the optical analogue refractometer reading higher than the digital refractometer (mean difference 0.0006, sd 0.0012). Paired refractometer measurements varied by <0.002 in 91.5 per cent of cases. The optical analogue and digital refractometer readings showed excellent correlation with osmolality (r=0.980 and r=0.977, respectively, P<0.001 in both cases). Despite statistical significance, the difference between the two refractometers is unlikely to be clinically significant. Both instruments provide an accurate assessment of USG in dogs.

  1. Reinnervation of bilateral posterior cricoarytenoid muscles using the left phrenic nerve in patients with bilateral vocal fold paralysis.

    Directory of Open Access Journals (Sweden)

    Meng Li

    Full Text Available OBJECTIVE: To evaluate the feasibility, effectiveness, and safety of reinnervation of the bilateral posterior cricoarytenoid (PCA muscles using the left phrenic nerve in patients with bilateral vocal fold paralysis. METHODS: Forty-four patients with bilateral vocal fold paralysis who underwent reinnervation of the bilateral PCA muscles using the left phrenic nerve were enrolled in this study. Videostroboscopy, perceptual evaluation, acoustic analysis, maximum phonation time, pulmonary function testing, and laryngeal electromyography were performed preoperatively and postoperatively. Patients were followed-up for at least 1 year after surgery. RESULTS: Videostroboscopy showed that within 1 year after reinnervation, abductive movement could be observed in the left vocal folds of 87% of patients and the right vocal folds of 72% of patients. Abductive excursion on the left side was significantly larger than that on the right side (P 0.05. No patients developed immediate dyspnea after surgery, and the pulmonary function parameters recovered to normal reference value levels within 1 year. Postoperative laryngeal electromyography confirmed successful reinnervation of the bilateral PCA muscles. Eighty-seven percent of patients in this series were decannulated and did not show obvious dyspnea after physical activity. Those who were decannulated after subsequent arytenoidectomy were not included in calculating the success rate of decannulation. CONCLUSIONS: Reinnervation of the bilateral PCA muscles using the left phrenic nerve can restore inspiratory vocal fold abduction to a physiologically satisfactory extent while preserving phonatory function at the preoperative level without evident morbidity.

  2. Reinnervation of Bilateral Posterior Cricoarytenoid Muscles Using the Left Phrenic Nerve in Patients with Bilateral Vocal Fold Paralysis

    Science.gov (United States)

    Zheng, Hongliang; Chen, Donghui; Zhu, Minhui; Wang, Wei; Liu, Fei; Zhang, Caiyun

    2013-01-01

    Objective To evaluate the feasibility, effectiveness, and safety of reinnervation of the bilateral posterior cricoarytenoid (PCA) muscles using the left phrenic nerve in patients with bilateral vocal fold paralysis. Methods Forty-four patients with bilateral vocal fold paralysis who underwent reinnervation of the bilateral PCA muscles using the left phrenic nerve were enrolled in this study. Videostroboscopy, perceptual evaluation, acoustic analysis, maximum phonation time, pulmonary function testing, and laryngeal electromyography were performed preoperatively and postoperatively. Patients were followed-up for at least 1 year after surgery. Results Videostroboscopy showed that within 1 year after reinnervation, abductive movement could be observed in the left vocal folds of 87% of patients and the right vocal folds of 72% of patients. Abductive excursion on the left side was significantly larger than that on the right side (P 0.05). No patients developed immediate dyspnea after surgery, and the pulmonary function parameters recovered to normal reference value levels within 1 year. Postoperative laryngeal electromyography confirmed successful reinnervation of the bilateral PCA muscles. Eighty-seven percent of patients in this series were decannulated and did not show obvious dyspnea after physical activity. Those who were decannulated after subsequent arytenoidectomy were not included in calculating the success rate of decannulation. Conclusions Reinnervation of the bilateral PCA muscles using the left phrenic nerve can restore inspiratory vocal fold abduction to a physiologically satisfactory extent while preserving phonatory function at the preoperative level without evident morbidity. PMID:24098581

  3. MRI features of bilateral parotid haemangiomas of infancy

    International Nuclear Information System (INIS)

    Andronikou, Savvas; Jadwat, Saaleeha; McHugh, Kieran; Linward, Jane

    2003-01-01

    The aim of this article is to report the MRI features of bilateral parotid haemangiomas of infancy and highlight the diagnostic and prognostic value of MRI especially with regard to those lesions that may cause respiratory compromise. Retrospective review of MRI scans in six infants with bilateral parotid haemangiomas. The bilateral haemangiomas were symmetrical in all but one patient. On T1-weighted images the masses were isointense to muscle and on T2 they were hyperintense with numerous small vessels giving a septated appearance. There was vivid enhancement with gadolinium in all cases. In three patients, deep bilateral extensions were demonstrated involving the parapharyngeal spaces resulting in respiratory compromise which required tracheostomy. Bilateral parotid haemangiomas are rare, but when present may have deep extensions, which can result in respiratory compromise requiring tracheostomy. (orig.)

  4. MRI features of bilateral parotid haemangiomas of infancy

    Energy Technology Data Exchange (ETDEWEB)

    Andronikou, Savvas; Jadwat, Saaleeha [Institute of Child Health, University of Cape Town, Klipfontein Road, Rondebosch, 7700, Cape Town (South Africa); McHugh, Kieran; Linward, Jane [Department of Radiology, Great Ormond Street Hospital for Children, London, WC1N 3JH (United Kingdom)

    2003-04-01

    The aim of this article is to report the MRI features of bilateral parotid haemangiomas of infancy and highlight the diagnostic and prognostic value of MRI especially with regard to those lesions that may cause respiratory compromise. Retrospective review of MRI scans in six infants with bilateral parotid haemangiomas. The bilateral haemangiomas were symmetrical in all but one patient. On T1-weighted images the masses were isointense to muscle and on T2 they were hyperintense with numerous small vessels giving a septated appearance. There was vivid enhancement with gadolinium in all cases. In three patients, deep bilateral extensions were demonstrated involving the parapharyngeal spaces resulting in respiratory compromise which required tracheostomy. Bilateral parotid haemangiomas are rare, but when present may have deep extensions, which can result in respiratory compromise requiring tracheostomy. (orig.)

  5. Bilateral Traumatic Globe Luxation with Optic Nerve Transection

    Directory of Open Access Journals (Sweden)

    Levent Tok

    2014-12-01

    Full Text Available Purpose: The purpose of this study was to document clinical findings and management of a patient with bilateral globe luxation and optic nerve transection. Materials and Methods: A 25-year-old female patient was admitted to the emergency department with bilateral traumatic globe luxation following a motor vehicle accident. Results: Visual acuity testing showed no light perception. The right pupil was dilated and bilaterally did not react to light. The globes were bilaterally intact. A computed tomography scan revealed Le Fort type II fractures, bilateral optic nerve transection and disruption of all extraocular muscles. The globes of the patient were bilaterally reduced into the orbit. However, the patient developed phthisis bulbi in the right eye at month 3. Conclusion: Globe luxation presents a dramatic clinical picture, and may lead to the development of severe complications due to the concomitance of complete optic nerve dissection and multiple traumas. Even if the luxated globe is repositioned into the orbit, there is still an increased risk of the development of phthisis due to ischemia.

  6. Bilateral Traumatic Globe Luxation with Optic Nerve Transection

    Science.gov (United States)

    Tok, Levent; Tok, Ozlem Yalcin; Argun, Tugba Cakmak; Yilmaz, Omer; Gunes, Alime; Unlu, Elif Nisa; Sezer, Sezgin; Ibisoglu, Seda; Argun, Mehmet

    2014-01-01

    Purpose The purpose of this study was to document clinical findings and management of a patient with bilateral globe luxation and optic nerve transection. Materials and Methods A 25-year-old female patient was admitted to the emergency department with bilateral traumatic globe luxation following a motor vehicle accident. Results Visual acuity testing showed no light perception. The right pupil was dilated and bilaterally did not react to light. The globes were bilaterally intact. A computed tomography scan revealed Le Fort type II fractures, bilateral optic nerve transection and disruption of all extraocular muscles. The globes of the patient were bilaterally reduced into the orbit. However, the patient developed phthisis bulbi in the right eye at month 3. Conclusion Globe luxation presents a dramatic clinical picture, and may lead to the development of severe complications due to the concomitance of complete optic nerve dissection and multiple traumas. Even if the luxated globe is repositioned into the orbit, there is still an increased risk of the development of phthisis due to ischemia. PMID:25606034

  7. Bilateral adrenal masses: a single-centre experience

    Directory of Open Access Journals (Sweden)

    Nilesh Lomte

    2016-05-01

    Full Text Available Background Bilateral adrenal masses may have aetiologies like hyperplasia and infiltrative lesions, besides tumours. Hyperplastic and infiltrative lesions may have coexisting hypocortisolism. Bilateral tumours are likely to have hereditary/syndromic associations. The data on clinical profile of bilateral adrenal masses are limited. Aims To analyse clinical, biochemical and radiological features, and management outcomes in patients with bilateral adrenal masses. Methods Retrospective analysis of 70 patients with bilateral adrenal masses presenting to a single tertiary care endocrine centre from western India (2002–2015. Results The most common aetiology was pheochromocytoma (40%, followed by tuberculosis (27.1%, primary adrenal lymphoma (PAL (10%, metastases (5.7%, non-functioning adenomas (4.3%, primary bilateral macronodular adrenal hyperplasia (4.3%, and others (8.6%. Age at presentation was less in patients with pheochromocytoma (33 years and tuberculosis (41 years compared with PAL (48 years and metastases (61 years (P<0.001. The presenting symptoms for pheochromocytoma were hyperadrenergic spells (54% and abdominal pain (29%, whereas tuberculosis presented with adrenal insufficiency (AI (95%. The presenting symptoms for PAL were AI (57% and abdominal pain (43%, whereas all cases of metastasis had abdominal pain. Mean size of adrenal masses was the largest in lymphoma (5.5cm followed by pheochromocytoma (4.8cm, metastasis (4cm and tuberculosis (2.1cm (P<0.001. Biochemically, most patients with pheochromocytoma (92.8% had catecholamine excess. Hypocortisolism was common in tuberculosis (100% and PAL (71.4% and absent with metastases (P<0.001. Conclusion In evaluation of bilateral adrenal masses, age at presentation, presenting symptoms, lesion size, and biochemical features are helpful in delineating varied underlying aetiologies.

  8. Bilateral adrenal masses: a single-centre experience

    Science.gov (United States)

    Bandgar, Tushar; Khare, Shruti; Jadhav, Swati; Lila, Anurag; Goroshi, Manjunath; Kasaliwal, Rajeev; Khadilkar, Kranti; Shah, Nalini S

    2016-01-01

    Background Bilateral adrenal masses may have aetiologies like hyperplasia and infiltrative lesions, besides tumours. Hyperplastic and infiltrative lesions may have coexisting hypocortisolism. Bilateral tumours are likely to have hereditary/syndromic associations. The data on clinical profile of bilateral adrenal masses are limited. Aims To analyse clinical, biochemical and radiological features, and management outcomes in patients with bilateral adrenal masses. Methods Retrospective analysis of 70 patients with bilateral adrenal masses presenting to a single tertiary care endocrine centre from western India (2002–2015). Results The most common aetiology was pheochromocytoma (40%), followed by tuberculosis (27.1%), primary adrenal lymphoma (PAL) (10%), metastases (5.7%), non-functioning adenomas (4.3%), primary bilateral macronodular adrenal hyperplasia (4.3%), and others (8.6%). Age at presentation was less in patients with pheochromocytoma (33 years) and tuberculosis (41 years) compared with PAL (48 years) and metastases (61 years) (P<0.001). The presenting symptoms for pheochromocytoma were hyperadrenergic spells (54%) and abdominal pain (29%), whereas tuberculosis presented with adrenal insufficiency (AI) (95%). The presenting symptoms for PAL were AI (57%) and abdominal pain (43%), whereas all cases of metastasis had abdominal pain. Mean size of adrenal masses was the largest in lymphoma (5.5cm) followed by pheochromocytoma (4.8cm), metastasis (4cm) and tuberculosis (2.1cm) (P<0.001). Biochemically, most patients with pheochromocytoma (92.8%) had catecholamine excess. Hypocortisolism was common in tuberculosis (100%) and PAL (71.4%) and absent with metastases (P<0.001). Conclusion In evaluation of bilateral adrenal masses, age at presentation, presenting symptoms, lesion size, and biochemical features are helpful in delineating varied underlying aetiologies. PMID:27037294

  9. Bilateral Ovarian Fibrothecoma Associated with Ascites, Bilateral Pleural Effusion, and Marked Elevated Serum CA-125

    Directory of Open Access Journals (Sweden)

    Védi André Serges Loué

    2013-01-01

    Full Text Available Background. The risk of ovarian cancer is increased in the association of ovarian tumor, ascites, and hydrothorax with the significant elevated tumor marker CA-125. However, this association can be observed in a rare clinical and benign pathological entity, that is Demons-Meigs’ syndrome. Objective. To describe a rare case of Demons-Meigs' syndrome observed in our department. Methods. A black African woman of 35 years old, seventh gravida and fourth parous, underwent a total abdominal hysterectomy with bilateral salpingoophorectomy for large bilateral ovarian masses associated with significant ascites, bilateral pleural effusion, and particular highly elevated tumor marker CA-125 (1835 UI/mL in a pronounced general alteration condition. Results. The postoperative course was uneventful characterized by a complete remission of hydrothorax and ascites with normal level of CA-125 three months after tumor excision. Histology of both masses revealed a bilateral ovarian fibrothecoma, a benign tumor of the ovary, thus confirming the diagnosis of Demons-Meigs’ syndrome. Conclusion. The Demons-Meigs syndrome, although it strongly mimics the clinical picture of malignant metastatic ovarian cancer, remains a disease with benign prognosis after surgical tumor resection. This is a rare condition that must be known and recognized by practitioners to avoid unnecessary practices.

  10. Effect of the nasal cycle on congestive response during bilateral nasal allergen provocation

    Directory of Open Access Journals (Sweden)

    Tomasz Gotlib

    2014-06-01

    Full Text Available Background. Bilateral nasal allergen provocation usually produces more pronounced obstruction of one nasal passage. It was found that this could be related to the stage of the nasal cycle before the provocation. objective. To discover whether the stage of the nasal cycle is decisive for asymmetry in congestive response observed during bilateral allergen nasal provocation. methods. Two bilateral nasal allergen provocations were performed in a group of 26 pollen-sensitive volunteers. Acoustic rhinometry measurements were taken during the nasal cycle, and then after the provocation. A cross-sectional area at the level of the inferior turbinate (CSA-2 was measured. Consecutive challenges were performed in the opposite phase of the nasal cycle: the side which had been wide just before the first challenge, was narrow before the second provocation. results. Asymmetry in CSA-2 reduction between the nasal passages was observed in most cases. Significant difference was observed between mean CSA-2 reduction rate (reactivity of the side that responded with greater congestion, and the opposite side. No significant difference was found in mean CSA-2 reduction rate between the side which was narrow, and the side which was wide before provocation. conclusions. Asymmetry of congestive response during bilateral nasal allergen provocation is not dependent on the stage of the nasal cycle preceding the challenge.

  11. Bilateral Tubal Pregnancy without Known Risk Factor

    Directory of Open Access Journals (Sweden)

    Hyacinthe Zamané

    2017-01-01

    Full Text Available Spontaneous bilateral ectopic gestation is very rare. The authors report a case diagnosed and taken care of at Yalgado Ouedraogo Teaching Hospital, Ouagadougou. It was a 30-year-old patient with no known pathological history. She had presented at the obstetric emergencies with a state of hypovolemic shock by haemoperitoneum with digestive disorders, pelvic pain, vaginal bleeding, and a mention of delayed menstruation. The ultrasound coupled with the urinary immunological pregnancy test confirmed the diagnosis of ruptured ectopic pregnancy and a bilateral form was suspected. A laparotomy in emergency confirmed the diagnosis of bilateral ectopic gestation with a right ampullary unruptured pregnancy and a left isthmic ruptured gestation. A bilateral salpingectomy was performed and counseling was made for the use of medical help of procreation in case of future need of pregnancy.

  12. Measuring opto-thermal parameters of basalt fibers using digital holographic microscopy.

    Science.gov (United States)

    Yassien, Khaled M; Agour, Mostafa

    2017-02-01

    A method for studying the effect of temperature on the optical properties of basalt fiber is presented. It is based on recording a set of phase-shifted digital holograms for the sample under the test. The holograms are obtained utilizing a system based on Mach-Zehnder interferometer, where the fiber sample inserted in an immersion liquid is placed within a temperature controlled chamber. From the recorded digital holograms the optical path differences which are used to calculate the refractive indices are determined. The accuracy in the measurement of refractive indices is in the range of 4 × 10 -4 . The influence of temperature on the dispersion parameters, polarizability per unit volume and dielectric susceptibility are also obtained. Moreover, the values of dispersion and oscillation energies and Cauchy's constants are provided at different temperatures. © 2016 Wiley Periodicals, Inc.

  13. Influence of Wilbraham-Gibbs Phenomenon on Digital Stochastic Measurement of EEG Signal Over an Interval

    Directory of Open Access Journals (Sweden)

    Sovilj P.

    2014-10-01

    Full Text Available Measurement methods, based on the approach named Digital Stochastic Measurement, have been introduced, and several prototype and small-series commercial instruments have been developed based on these methods. These methods have been mostly investigated for various types of stationary signals, but also for non-stationary signals. This paper presents, analyzes and discusses digital stochastic measurement of electroencephalography (EEG signal in the time domain, emphasizing the problem of influence of the Wilbraham-Gibbs phenomenon. The increase of measurement error, related to the Wilbraham-Gibbs phenomenon, is found. If the EEG signal is measured and measurement interval is 20 ms wide, the average maximal error relative to the range of input signal is 16.84 %. If the measurement interval is extended to 2s, the average maximal error relative to the range of input signal is significantly lowered - down to 1.37 %. Absolute errors are compared with the error limit recommended by Organisation Internationale de Métrologie Légale (OIML and with the quantization steps of the advanced EEG instruments with 24-bit A/D conversion

  14. Temperature sensitivity study of eddy current and digital gauge probes for nuclear fuel rod oxide measurement

    Science.gov (United States)

    Beck, Faith R.; Lind, R. Paul; Smith, James A.

    2018-04-01

    Novel fuels are part of the nationwide effort to reduce the enrichment of Uranium for energy production. Performance of such fuels is determined by irradiating their surfaces. To test irradiated samples, the instrumentation must operate remotely. The plate checker used in this experiment at Idaho National Lab (INL) performs non-destructive testing on fuel rod and plate geometries with two different types of sensors: eddy current and digital thickness gauges. The sensors measure oxide growth and total sample thickness on research fuels, respectively. Sensor measurement accuracy is crucial because even 10 microns of error is significant when determining the viability of an experimental fuel. One parameter known to affect the eddy current and thickness gauge sensors is temperature. Since both sensor accuracies depend on the ambient temperature of the system, the plate checker has been characterized for these sensitivities. The manufacturer of the digital gauge probes has noted a rather large coefficient of thermal expansion for their linear scale. It should also be noted that the accuracy of the digital gauge probes are specified at 20°C, which is approximately 7°C cooler than the average hot-cell temperature. In this work, the effect of temperature on the eddy current and digital gauge probes is studied, and thickness measurements are given as empirical functions of temperature.

  15. [Bilateral torticollis].

    Science.gov (United States)

    Kustos, T; Magdics, M

    1993-12-19

    Bilateral torticollis is a very rare form of a well known deformity i.e. muscular torticollis. This malformation might present a differential diagnostic problem both for orthopaedic surgeons and ophthalmologists, as well as, for neurologists. In agreement with the literature, the role of an injury during labour or defective embriogenesis is suggested to play a part.

  16. Digital Pulser for Characterization and Diagnostic of Digital Spectrometers

    International Nuclear Information System (INIS)

    Jordanov, V.T.

    2013-01-01

    The concept and the realization of the digital pulser are presented. The digital pulser is implemented as a functional block of a digital spectrometer. The digital pulser provides noise free and distortion free measurement of the inherent electronic noise of the entire spectroscopy system. The digital pulser is introduced at the end of the signal processing chain and allows separate evaluation of the individual spectroscopy blocks. It offers the ability to characterize and diagnose problems of the digital pulse height analysers by grounding their inputs. The digital pulser does not interfere with the processing of the detector signals and does not contribute to the dead time and the pulse pile-up of the system. The digital pulser peaks are not affected by the presence of detector pulses and are stored in a separate histogram memory leaving the detector spectrum undistorted. (author)

  17. Bilateral optic neuropathy in acute cr yptococcal meningitis

    Directory of Open Access Journals (Sweden)

    Qi Zhe Ngoo

    2016-11-01

    Full Text Available We reported a case of cryptococcal meningitis presenting with bilateral optic neuropathy in an immunocompetent patient. A 64-year-old Malay gentleman with no medical comorbidities presented with acute bilateral blurring of vision for a week, which was associated with generalised throbbing headache and low grade fever. He also had somnolence and altered consciousness. Visual acuity in both eyes was no perception of light with poor pupillary reflexes. Extraocular muscle movements were normal. Anterior segments were unremarkable bilaterally. Fundoscopy revealed bilateral optic disc swelling. CT scan of the brain showed multifocal infarct, but no meningeal enhancement or mass. Cerebrospinal fluid opening pressure was normal, while its culture grew Cryptococcus neoformans. A diagnosis of cryptococcal meningitis with bilateral optic neuropathy was made. Patient was treated with a six-week course of intravenous fluconazole and started concomitantly on a fortnight's course of intravenous amphotericin B. After that, his general condition improved, but there was still no improvement in his visual acuity. On reviewing at two months post-initiation of treatment, fundi showed bilateral optic atrophy. Bilateral optic neuropathy secondary to cryptococcal meningitis was rare. The prognosis was guarded due to the sequelae of optic atrophy. Anti-fungal medication alone may not be sufficient to manage this condition. However, evidence for other treatment modalities is still lacking and further clinical studies are required.

  18. Palpebral position interdependence in blepharoptosis: comparison of the effect of instillation of 10% phenylephrine drop and digital lifting

    Directory of Open Access Journals (Sweden)

    Ivana Cardoso Pereira

    2014-12-01

    Full Text Available Purpose: To quantify and compare the effects of instillation with 10% phenylephrine and digital lifting on the contralateral upper eyelid of patients with involutional bilateral blepharoptosis. Methods: The present prospective clinical study involved patients with involutional bilateral blepharoptosis who underwent two tests: 1 digital lifting of the more ptotic eyelid and observation of the effect on the contralateral eyelid and 2 instillation of two drops of 10% phenylephrine in the more ptotic eye and observation of the effect on the contralateral eyelid. Patients were filmed before and 5, 10, and 15 min after instillation, and the resulting images were analyzed to obtain eyelid measurements. The results were tested using a linear mixed-effects model. Results: A total of 27 patients, ranging from 52 to 82 years of age (mean age 68.51 ± 8.21 years, 24 (88.88% of whom were women, were included in the present study. In eyes that received instillation, the marginal distance reflex-1 (MDR1 values increased from baseline (1.21 ± 0.60 mm until 10 min after instillation, then remained statistically unchanged until 15 min after instillation (2.42 ± 0.90 mm. Significant differences were observed in the contralateral eye of the group that underwent digital lifting (1.51 ± 0.53 mm - 1.63 ± 0.56 mm and in the contralateral eye of the group that underwent 10% phenylephrine instillation (1.38 ± 0.54 mm - 1.63 ± 0.56 mm; p=0.02 and p<0.01, respectively. Conclusion: In all eyes, 10% phenylephrine elevated the upper eyelid, with improved eyelid height at 10 min after instillation. Significant differences were observed in the height of the contralateral eyelid when compared before and after each intervention in each group; however, this difference was very small and nearly undetectable by conventional clinical evaluation in the digital lifting group. However, the 10% phenylephrine eye-drop test resulted in substantial changes in MDR1 values in the

  19. Bilateral export trade and income similarity: Does the Linder hypothesis hold for agricultural and food trade?

    OpenAIRE

    Steinbach, Sandro

    2015-01-01

    In this paper we invesƟgate the Linder hypothesis for bilateral export trade in agricultural and food products by uƟlizing the sectoral gravity equaƟon derived in Hallak (2010). Based on a sample of 152 countries, we study the relaƟonship for 737 agricultural and food products at the 6-digit HS code level, using trade data for 1995-2012. We esƟmate the gravity equaƟon year by and year and sector by sector, analyzing the esƟmates of Linder's term for two specificaƟons of the similarity index. W...

  20. Neglected simultaneous bilateral femoral neck fractures secondary to narcotic drug abuse treated by bilateral one-staged hemiarthroplasty: a case report

    Directory of Open Access Journals (Sweden)

    Vahedi Ehsan

    2010-06-01

    Full Text Available Abstract Simultaneous bilateral femoral neck fractures are extremely rare and associated with various conditions. Up to now Most cases had correlations with major trauma, repetitive minor trauma, seizure, parathyroid or renal dysfunction, anti-epileptic medications, seizure, etc. A 28-year-old addict man referred to us with a 10-year history of narcotic drug abuse and history of 8 months bilateral groin pain. He admitted with displaced bilateral femoral neck fracture. Because of long duration of this condition and osteonecrosis revealed on bone scan, one-staged bilateral hip hemiarthroplasty was done. A good function was noted after surgery to 4-month follow up. Up to now, have not be founded in the literature that a case of bilateral femoral neck fracture associated with narcotic drug abuse. Because of negative effects of opium or smoking on bone tissues, a simple bone pain should aware us about the risk of stress or fatigue fracture.

  1. Simultaneous Bilateral Transient Osteoporosis of the Hip without Pregnancy

    Directory of Open Access Journals (Sweden)

    Yasuaki Okada

    2016-01-01

    Full Text Available Transient osteoporosis of the hip (TOH is a rare disorder characterized by acute severe coxalgia and temporary osteopenia in the proximal femur. Although most cases were unilateral or staged bilateral TOH, some authors reported that the pregnant patients simultaneously had TOH in their bilateral hips. However, there has been no report of simultaneous bilateral TOH in the patient without pregnancy. A 25-year-old Japanese woman without pregnancy had acute simultaneous bilateral hip pain. Plain X-ray of the bilateral hips did not show a periarticular osteopenia. However, magnetic resonance image obtained one week after the onset demonstrated increased T2-weighted signal intensity and decreased T1-weighted signal intensity in the bilateral femoral heads. She was treated conservatively, and follow-up magnetic resonance image at seven weeks after the onset returned to normal bone marrow signal intensity. Her bilateral coxalgia subsided gradually. At one year after the onset, she had no sign of symptomatic flair. Our experience with this case indicates that recognizing the possibility of simultaneous bilateral TOH is important unless the patient is pregnant, and magnetic resonance image is predictable test to make a diagnosis of TOH, even in the absence of abnormal finding on plain X-ray.

  2. Development of the Digital Health Literacy Instrument : Measuring a Broad Spectrum of Health 1.0 and Health 2.0 Skills

    NARCIS (Netherlands)

    van der Vaart, Rosalie; Drossaert, Constance

    2017-01-01

    Background: With the digitization of health care and the wide availability of Web-based applications, a broad set of skills is essential to properly use such facilities; these skills are called digital health literacy or eHealth literacy. Current instruments to measure digital health literacy focus

  3. Segmentation of ribs in digital chest radiographs

    Science.gov (United States)

    Cong, Lin; Guo, Wei; Li, Qiang

    2016-03-01

    Ribs and clavicles in posterior-anterior (PA) digital chest radiographs often overlap with lung abnormalities such as nodules, and cause missing of these abnormalities, it is therefore necessary to remove or reduce the ribs in chest radiographs. The purpose of this study was to develop a fully automated algorithm to segment ribs within lung area in digital radiography (DR) for removal of the ribs. The rib segmentation algorithm consists of three steps. Firstly, a radiograph was pre-processed for contrast adjustment and noise removal; second, generalized Hough transform was employed to localize the lower boundary of the ribs. In the third step, a novel bilateral dynamic programming algorithm was used to accurately segment the upper and lower boundaries of ribs simultaneously. The width of the ribs and the smoothness of the rib boundaries were incorporated in the cost function of the bilateral dynamic programming for obtaining consistent results for the upper and lower boundaries. Our database consisted of 93 DR images, including, respectively, 23 and 70 images acquired with a DR system from Shanghai United-Imaging Healthcare Co. and from GE Healthcare Co. The rib localization algorithm achieved a sensitivity of 98.2% with 0.1 false positives per image. The accuracy of the detected ribs was further evaluated subjectively in 3 levels: "1", good; "2", acceptable; "3", poor. The percentages of good, acceptable, and poor segmentation results were 91.1%, 7.2%, and 1.7%, respectively. Our algorithm can obtain good segmentation results for ribs in chest radiography and would be useful for rib reduction in our future study.

  4. Bilateral Wilms' tumor

    International Nuclear Information System (INIS)

    Malcolm, A.W.; Jaffe, N.; Folkman, M.J.; Cassady, J.R.

    1980-01-01

    Twenty children with bilateral Wilms' tumor were presented to the Children's Hospital Medical Center and Children's Cancer Research Foundation, Sidney Farber Cancer Institute, and Joint Center for Radiation Therapy (CHMC-CCRF, SFCI, JCRT) from January 1, 1956 to December 31, 1976. Of these 20, 16 had simultaneous and 4 had metachronous disease on presentation. All patients were treated with surgery, radiation and chemotherapy. Of the 16 patients with simultaneous disease, 10 (63%) are alive and free of disease 12+ to 175+ months post diagnosis and treatment, with median follow-up of 121 months. There were no long-term survivors in the metachronous group; all were dead of disease within 21 months from initial presentation of original tumor. With these data we relate prognosis to extent of disease and discuss a general approach to the management of bilateral Wilms' tumor

  5. Bilateral multiligament injury of knee caused by entangled dupatta

    Directory of Open Access Journals (Sweden)

    Shrinand V Vaidya

    2012-01-01

    Full Text Available We report a rare case of bilateral multiligament knee injury in an 18-year-old female employed in garment industry. Patient was wearing salwar kameez and dupatta while operating an electric laundry machine. In this case we discuss a peculiar mechanism of injury caused due to wearing dupatta near working site and suggest simple preventive measures.

  6. A comparison of the accuracy of film-screen mammography, full-field digital mammography, and digital breast tomosynthesis

    International Nuclear Information System (INIS)

    Michell, M.J.; Iqbal, A.; Wasan, R.K.; Evans, D.R.; Peacock, C.; Lawinski, C.P.; Douiri, A.; Wilson, R.; Whelehan, P.

    2012-01-01

    Aim: To measure the change in diagnostic accuracy of conventional film-screen mammography and full-field digital mammography (FFDM) with the addition of digital breast tomosynthesis (DBT) in women recalled for assessment following routine screening. Materials and methods: Ethics approval for the study was granted. Women recalled for assessment following routine screening with screen-film mammography were invited to participate. Participants underwent bilateral, two-view FFDM and two-view DBT. Readers scored each lesion separately for probability of malignancy on screen-film mammography, FFDM, and then DBT. The scores were compared with the presence or absence of malignancy based on the final histopathology outcome. Results: Seven hundred and thirty-eight women participated (93.2% recruitment rate). Following assessment 204 (26.8%) were diagnosed as malignant (147 invasive and 57 in-situ tumours), 286 (37.68%) as benign, and 269 (35.4%) as normal. The diagnostic accuracy was evaluated by using receiving operating characteristic (ROC) and measurement of area under the curve (AUC). The AUC values demonstrated a significant (p = 0.0001) improvement in the diagnostic accuracy with the addition of DBT combined with FFDM and film-screen mammography (AUC = 0.9671) when compared to FFDM plus film-screen mammography (AUC = 0.8949) and film-screen mammography alone (AUC = 0.7882). The effect was significantly greater for soft-tissue lesions [AUC was 0.9905 with the addition of DBT and AUC was 0.9201 for FFDM with film-screen mammography combined (p = 0.0001)] compared to microcalcification [with the addition of DBT (AUC = 0.7920) and for FFDM with film-screen mammography combined (AUC = 0.7843; p = 0.3182)]. Conclusion: The addition of DBT increases the accuracy of mammography compared to FFDM and film-screen mammography combined and film-screen mammography alone in the assessment of screen-detected soft-tissue mammographic abnormalities.

  7. Funding analysis of bilateral autologous free-flap breast reconstructions in Australia.

    Science.gov (United States)

    Sinha, Shiba; Ruskin, Olivia; McCombe, David; Morrison, Wayne; Webb, Angela

    2015-08-01

    Bilateral breast reconstructions are being increasingly performed. Autologous free-flap reconstructions represent the gold standard for post-mastectomy breast reconstruction but are resource intensive. This study aims to investigate the difference between hospital reimbursement and true cost of bilateral autologous free-flap reconstructions. Retrospective analysis of patients who underwent bilateral autologous free-flap reconstructions at a single Australian tertiary referral centre was performed. Hospital reimbursement was determined from coding analysis. A true cost analysis was also performed. Comparisons were made considering the effect of timing, indication and complications of the procedure. Forty-six bilateral autologous free-flap procedures were performed (87 deep inferior epigastric perforators (DIEPs), four superficial inferior epigastric artery perforator flaps (SIEAs) and one muscle-sparing free transverse rectus abdominis myocutaneous flap (MS-TRAM)). The mean funding discrepancy between hospital reimbursement and actual cost was $12,137 ± $8539 (mean ± standard deviation (SD)) (n = 46). Twenty-four per cent (n = 11) of the cases had been coded inaccurately. If these cases were excluded from analysis, the mean funding discrepancy per case was $9168 ± $7453 (n = 35). Minor and major complications significantly increased the true cost and funding discrepancy (p = 0.02). Bilateral free-flap breast reconstructions performed in Australian public hospitals result in a funding discrepancy. Failure to be economically viable threatens the provision of this procedure in the public system. Plastic surgeons and hospital managers need to adopt measures in order to make these gold-standard procedures cost neutral. Copyright © 2015 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  8. Simultaneous bilateral patellar tendon rupture ?

    OpenAIRE

    Moura, Diogo Lino; Marques, Jos? Pedro; Lucas, Francisco Manuel; Fonseca, Fernando Pereira

    2016-01-01

    Bilateral patellar tendon rupture is a rare entity, often associated with systemic diseases and patellar tendinopathy. The authors report a rare case of a 34-year-old man with simultaneous bilateral rupture of the patellar tendon caused by minor trauma. The patient is a retired basketball player with no past complaints of chronic knee pain and a history of steroid use. Surgical management consisted in primary end-to-end tendon repair protected temporarily with cerclage wiring, followed by a s...

  9. Quality assurance in digital radiography

    International Nuclear Information System (INIS)

    Busch, H.P.; Lehmann, K.J.

    1989-01-01

    At present, there is no standard way of evaluating performance characteristics of digital radiography systems. Continuous measurements of performance parameters are necessary in order to obtain images of high quality. Parameters of quality assurance in digital radiography, which can be evaluated with simple, quick methods, are spatial resolution, low-contrast detectability, dynamic range and exposure dose. Spatial resolution was determined by a lead bar pattern, whereas the other parameters were measured by commercially available phantoms. Performance measurements of 10 digital subtraction angiography (DSA) units and one digital radiography system for unsubtracted digital radiography were assessed. From these results, recommendations for performance parameter levels will be discussed. (author)

  10. Maxillary arch width in unoperated adult bilateral cleft lip and alveolus and complete bilateral cleft lip and palate.

    NARCIS (Netherlands)

    Latief, B.S.; Lekkas, C.; Kuijpers, M.A.R.

    2010-01-01

    OBJECTIVES: To study maxillary arch width in adult patients with bilateral cleft lip and alveolus (BCLA) or with complete bilateral cleft lip and palate (BCLP), who have not had any surgery. SETTING AND SAMPLING POPULATION: Eighteen patients with BCLA, 13 patients with BCLP, and 24 controls from

  11. Bilateral ovarian tumour in a young girl | Govindarajan | African ...

    African Journals Online (AJOL)

    Bilateral ovarian tumour in a girl presents the dilemma of conservative versus aggressive approach towards these tumours. When faced with suspicious tumour and complete replacement of the ovaries bilaterally, bilateral oophorectomy is a viable option, though the certain possibility of infertility and lifelong hormonal ...

  12. Bilateral elastofibroma dorsi: A case report

    OpenAIRE

    Molini, L.; Ciortan, E.; Bianchi, S.

    2010-01-01

    Elastofibroma dorsi is a rare pseudotumoral lesion located in the periscapular region. Ultrasound can be used to evaluate its dimensions, margins, and internal structure. In the presence of bilateralism, diagnosis can be made on the basis of clinical and sonographic findings. The authors present a case of bilateral elastofibroma dorsi in which the clinical and ultrasound diagnosis was confirmed by magnetic resonance imaging.

  13. Unusual Presentation of Recurrent Pyogenic Bilateral Psoas Abscess Causing Bilateral Pulmonary Embolism by Iliac Vein Compression

    OpenAIRE

    Ijaz, Mohsin; Sakam, Sailaja; Ashraf, Umair; Marquez, Jose Gomez

    2015-01-01

    Patient: Male, 47 Final Diagnosis: Bilateral psoas abscess • acute lower extremity deep vein thrombosis • bilateral pulmonary embolism Symptoms: Progressive left leg swelling • productive cough with whitish sputum • right flank pain Medication: Antibiotics and anticoagulation Clinical Procedure: CT-guided percutaneous drain placement Specialty: Internal Medicine/Critical Care Objective: Unusual presentation Background: Psoas abscesses are a known cause of back pain, but they have not been rep...

  14. A digital method for period measurements in a nuclear reactor; Um metodo digital para medidas de periodo em um reator nuclear

    Energy Technology Data Exchange (ETDEWEB)

    Mundim, Sergio Gorretta

    1971-02-15

    The present paper begins by giving a theoretical treatment for the nuclear reactor period. The conventional method of measuring the period is analysed and some previously developed digital methods are described. The paper criticises the latter, pointing out some deficiencies which the proposed process is able to eliminate. All errors connected with this process are also analysed. The paper presents suitable solutions to reduce them to a minimum. The total error is found to he less than the error presented by the other methods described. A digital period meter is designed with memory resources and an automatic scaler changer. Integrated circuits specifications are used in it. Real time experiments with nuclear reactors were made in order to check te validity of the method. The data acquired were applied to a simulated digital period meter implemented in a general purpose computer. The nuclear part of the work was developed at the 'Comissao Nacional de Energia Nuclear' and the simulation work was dane at the 'Departamento de Calculo Cientifico' of COPPE, which also advised the author in the completion of this thesis. (author)

  15. Bilateral acute iris transillumination: Case report

    Directory of Open Access Journals (Sweden)

    Cumali Degirmenci

    2016-04-01

    Full Text Available Bilateral acute iris transillumination (BAIT is a recently defined disease characterized with bilateral acute, severe pigment dispersion of iris and pupil sphincter paralysis. The etiopathogenesis of the disease is unknown, but antibiotics such as moxifloxacin, clarithromycin, viral infections, and fumigation therapies were considered as probable etiologic factors. A 33-year-old female was referred to our clinic for acute iridocyclitis refractory to azathioprine, colchicum and corticosteroid treatments. Ophthalmic examination revealed bilateral pigment dispersion, significant iris transillumination, heavy pigment deposition in iridocorneal angle, and elevated intraocular pressure. Upon systemic evaluation she was found to have bacterial urinary tract infection. BAIT is an important cause of pigment dispersion and clinicians must be vigilant for this condition to avoid unnecessary diagnostic tests and treatment.

  16. Effects of unilateral and bilateral plyometric training on power and jumping ability in women.

    Science.gov (United States)

    Makaruk, Hubert; Winchester, Jason B; Sadowski, Jerzy; Czaplicki, Adam; Sacewicz, Tomasz

    2011-12-01

    Makaruk, H, Winchester, JB, Sadowski, J, Czaplicki, A, and Sacewicz, T. Effects of unilateral and bilateral plyometric training on power and jumping ability in women. J Strength Cond Res 25(12): 3311-3318, 2011-The purpose of this study was to examine the effects of unilateral and bilateral plyometric exercise on peak power and jumping performance during different stages of a 12-week training and detraining in women. Forty-nine untrained but physically active female college students were randomly assigned to 1 of 3 groups: unilateral plyometric group (n = 16), bilateral plyometric group (BLE; n = 18), and a control group (n = 15). Peak power and jumping ability were assessed by means of the alternate leg tests (10-second Wingate test and 5 alternate leg bounds), bilateral leg test (countermovement jump [CMJ]) and unilateral leg test (unilateral CMJ). Performance indicators were measured pretraining, midtraining, posttraining, and detraining. Differences between dependent variables were assessed with a 3 × 4 (group × time) repeated analysis of variance with Tukey's post hoc test applied where appropriate. Effect size was calculated to determine the magnitude of significant differences between the researched parameters. Only the unilateral plyometric training produced significant (p 0.05) decrease power and jumping ability in all tests during detraining. These results suggest that unilateral plyometric exercises produce power and jumping performance during a shorter period when compared to bilateral plyometric exercises but achieved performance gains last longer after bilateral plyometric training. Practitioners should consider the inclusion of both unilateral and bilateral modes of plyometric exercise to elicit rapid improvements and guard against detraining.

  17. Practical Measurement and Productive Persistence: Strategies for Using Digital Learning System Data to Drive Improvement

    Science.gov (United States)

    Krumm, Andrew E.; Beattie, Rachel; Takahashi, Sola; D'Angelo, Cynthia; Feng, Mingyu; Cheng, Britte

    2016-01-01

    This paper outlines the development of practical measures of productive persistence using digital learning system data. Practical measurement refers to data collection and analysis approaches originating from improvement science; productive persistence refers to the combination of academic and social mindsets as well as learning behaviours that…

  18. Easy Leaf Area: Automated digital image analysis for rapid and accurate measurement of leaf area.

    Science.gov (United States)

    Easlon, Hsien Ming; Bloom, Arnold J

    2014-07-01

    Measurement of leaf areas from digital photographs has traditionally required significant user input unless backgrounds are carefully masked. Easy Leaf Area was developed to batch process hundreds of Arabidopsis rosette images in minutes, removing background artifacts and saving results to a spreadsheet-ready CSV file. • Easy Leaf Area uses the color ratios of each pixel to distinguish leaves and calibration areas from their background and compares leaf pixel counts to a red calibration area to eliminate the need for camera distance calculations or manual ruler scale measurement that other software methods typically require. Leaf areas estimated by this software from images taken with a camera phone were more accurate than ImageJ estimates from flatbed scanner images. • Easy Leaf Area provides an easy-to-use method for rapid measurement of leaf area and nondestructive estimation of canopy area from digital images.

  19. Cherenkov luminescence measurements with digital silicon photomultipliers: a feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Ciarrocchi, Esther; Belcari, Nicola; Guerra, Alberto Del [Department of Physics, University of Pisa, Pisa (Italy); INFN, section of Pisa, Pisa (Italy); Cherry, Simon R. [Department of Biomedical Engineering, University of California, Davis, CA (United States); Lehnert, Adrienne; Hunter, William C. J.; McDougald, Wendy; Miyaoka, Robert S.; Kinahan, Paul E. [Department of Radiology, University of Washington, Seattle, WA (United States)

    2015-11-16

    A feasibility study was done to assess the capability of digital silicon photomultipliers to measure the Cherenkov luminescence emitted by a β source. Cherenkov luminescence imaging (CLI) is possible with a charge coupled device (CCD) based technology, but a stand-alone technique for quantitative activity measurements based on Cherenkov luminescence has not yet been developed. Silicon photomultipliers (SiPMs) are photon counting devices with a fast impulse response and can potentially be used to quantify β-emitting radiotracer distributions by CLI. In this study, a Philips digital photon counting (PDPC) silicon photomultiplier detector was evaluated for measuring Cherenkov luminescence. The PDPC detector is a matrix of avalanche photodiodes, which were read one at a time in a dark count map (DCM) measurement mode (much like a CCD). This reduces the device active area but allows the information from a single avalanche photodiode to be preserved, which is not possible with analog SiPMs. An algorithm to reject the noisiest photodiodes and to correct the measured count rate for the dark current was developed. The results show that, in DCM mode and at (10–13) °C, the PDPC has a dynamic response to different levels of Cherenkov luminescence emitted by a β source and transmitted through an opaque medium. This suggests the potential for this approach to provide quantitative activity measurements. Interestingly, the potential use of the PDPC in DCM mode for direct imaging of Cherenkov luminescence, as a opposed to a scalar measurement device, was also apparent. We showed that a PDPC tile in DCM mode is able to detect and image a β source through its Cherenkov radiation emission. The detector’s dynamic response to different levels of radiation suggests its potential quantitative capabilities, and the DCM mode allows imaging with a better spatial resolution than the conventional event-triggered mode. Finally, the same acquisition procedure and data processing could

  20. Cherenkov luminescence measurements with digital silicon photomultipliers: a feasibility study

    International Nuclear Information System (INIS)

    Ciarrocchi, Esther; Belcari, Nicola; Guerra, Alberto Del; Cherry, Simon R.; Lehnert, Adrienne; Hunter, William C. J.; McDougald, Wendy; Miyaoka, Robert S.; Kinahan, Paul E.

    2015-01-01

    A feasibility study was done to assess the capability of digital silicon photomultipliers to measure the Cherenkov luminescence emitted by a β source. Cherenkov luminescence imaging (CLI) is possible with a charge coupled device (CCD) based technology, but a stand-alone technique for quantitative activity measurements based on Cherenkov luminescence has not yet been developed. Silicon photomultipliers (SiPMs) are photon counting devices with a fast impulse response and can potentially be used to quantify β-emitting radiotracer distributions by CLI. In this study, a Philips digital photon counting (PDPC) silicon photomultiplier detector was evaluated for measuring Cherenkov luminescence. The PDPC detector is a matrix of avalanche photodiodes, which were read one at a time in a dark count map (DCM) measurement mode (much like a CCD). This reduces the device active area but allows the information from a single avalanche photodiode to be preserved, which is not possible with analog SiPMs. An algorithm to reject the noisiest photodiodes and to correct the measured count rate for the dark current was developed. The results show that, in DCM mode and at (10–13) °C, the PDPC has a dynamic response to different levels of Cherenkov luminescence emitted by a β source and transmitted through an opaque medium. This suggests the potential for this approach to provide quantitative activity measurements. Interestingly, the potential use of the PDPC in DCM mode for direct imaging of Cherenkov luminescence, as a opposed to a scalar measurement device, was also apparent. We showed that a PDPC tile in DCM mode is able to detect and image a β source through its Cherenkov radiation emission. The detector’s dynamic response to different levels of radiation suggests its potential quantitative capabilities, and the DCM mode allows imaging with a better spatial resolution than the conventional event-triggered mode. Finally, the same acquisition procedure and data processing could

  1. Infectious mononucleosis presenting as bilateral acute dacryocystitis.

    Science.gov (United States)

    Atkinson, P L; Ansons, A M; Patterson, A

    1990-01-01

    A case of infectious mononucleosis presenting as bilateral acute dacryocystitis in a 7-year-old girl is reported. Acute dacryocystitis is uncommon in this age group, and an underlying systemic illness should be suspected particularly when it is bilateral. Images PMID:2275940

  2. Measurement facilities and accuracy limits of sampling digital interferometers. Meresi lehetoesegek es hibaanalizis digitalis mintavetelezoe interferometeren

    Energy Technology Data Exchange (ETDEWEB)

    Czitrovszky, A.; Jani, P.; Szoter, L.

    1990-12-15

    We discuss the measurement facilities of a recently development sampling digital interferometer for machine tool testing. As opposed to conventional interferometers the present device provides possibilities for the digital storage up to 4 kHz of the complete information of the motion so that displacement, velocity, acceleration and power density spectrum measurement can be performed. An estimation is given for the truncation, round-off, jitter and frequency-aliasing sources of error of the reconstructed motion parameters. On the basis of the Shannon sampling theory optimal conditions of measurement parameters are defined for the case when the accuracy of the reconstructed part of motion and vibration is equal to the resolution of the conventional interferometer. 7 refs., 3 figs., 1 tab.

  3. Similarity in Bilateral Isolated Internal Orbital Fractures.

    Science.gov (United States)

    Chen, Hung-Chang; Cox, Jacob T; Sanyal, Abanti; Mahoney, Nicholas R

    2018-04-13

    In evaluating patients sustaining bilateral isolated internal orbital fractures, the authors have observed both similar fracture locations and also similar expansion of orbital volumes. In this study, we aim to investigate if there is a propensity for the 2 orbits to fracture in symmetrically similar patterns when sustaining similar trauma. A retrospective chart review was performed studying all cases at our institution of bilateral isolated internal orbital fractures involving the medial wall and/or the floor at the time of presentation. The similarity of the bilateral fracture locations was evaluated using the Fisher's exact test. The bilateral expanded orbital volumes were analyzed using the Wilcoxon signed-rank test to assess for orbital volume similarity. Twenty-four patients with bilateral internal orbital fractures were analyzed for fracture location similarity. Seventeen patients (70.8%) had 100% concordance in the orbital subregion fractured, and the association between the right and the left orbital fracture subregion locations was statistically significant (P < 0.0001). Fifteen patients were analyzed for orbital volume similarity. The average orbital cavity volume was 31.2 ± 3.8 cm on the right and 32.0 ± 3.7 cm on the left. There was a statistically significant difference between right and left orbital cavity volumes (P = 0.0026). The data from this study suggest that an individual who suffers isolated bilateral internal orbital fractures has a statistically significant similarity in the location of their orbital fractures. However, there does not appear to be statistically significant similarity in the expansion of the orbital volumes in these patients.

  4. The effect of pitch, rhythm, and familiarity on working memory and anxiety as measured by digit recall performance.

    Science.gov (United States)

    Silverman, Michael J

    2010-01-01

    The purpose of this study was to isolate and quantitatively evaluate the effects of pitch and rhythm of unfamiliar and familiar melodies on working memory and anxiety as measured by sequential digit recall performance. Participants (N = 60) listened to 6 treatment conditions each consisting of 9 randomized monosyllabic digits. The digits were paired with (a) a familiar melody and pitch only, (b) a familiar melody and rhythm only, (c) a familiar melody with both pitch and rhythm, (d) an unfamiliar melody with pitch only, (e) an unfamiliar melody with rhythm only, and (f) an unfamiliar melody with both pitch and rhythm. The 6 different treatments were counterbalanced using a Latin square design in an attempt to control for order effects. Participants rated their state anxiety on a Likert-type scale before, midway through, and after the digits test. No statistically significant order, learning, or practice effects were found. A 3-way repeated-measures ANOVA indicated a statistically significant difference in digit recall performance across musical element conditions and groups. Results indicated that music majors outperformed nonmusic majors on the digit recall task. Participants were able to recall digits from the rhythm condition most accurately while recalling digits from pitch only and both pitch and rhythm conditions the least accurately. Graphic analysis of treatment as a function of sequential position indicated digit recall was best during conditions of primacy and recency. No main effects were found for the familiarity condition. Additionally, no main effects or interactions were found for the anxiety variable. The results of this study are congruent with existing working memory and music literature suggesting that pairing information with rhythm can facilitate recall, music majors outperform non-music majors, and recall accuracy is best in positions of primacy and recency. Implications for practice in therapy and education are made as well as suggestions for

  5. Reliability and Validity of Digital Imagery Methodology for Measuring Starting Portions and Plate Waste from School Salad Bars.

    Science.gov (United States)

    Bean, Melanie K; Raynor, Hollie A; Thornton, Laura M; Sova, Alexandra; Dunne Stewart, Mary; Mazzeo, Suzanne E

    2018-04-12

    Scientifically sound methods for investigating dietary consumption patterns from self-serve salad bars are needed to inform school policies and programs. To examine the reliability and validity of digital imagery for determining starting portions and plate waste of self-serve salad bar vegetables (which have variable starting portions) compared with manual weights. In a laboratory setting, 30 mock salads with 73 vegetables were made, and consumption was simulated. Each component (initial and removed portion) was weighed; photographs of weighed reference portions and pre- and post-consumption mock salads were taken. Seven trained independent raters visually assessed images to estimate starting portions to the nearest ¼ cup and percentage consumed in 20% increments. These values were converted to grams for comparison with weighed values. Intraclass correlations between weighed and digital imagery-assessed portions and plate waste were used to assess interrater reliability and validity. Pearson's correlations between weights and digital imagery assessments were also examined. Paired samples t tests were used to evaluate mean differences (in grams) between digital imagery-assessed portions and measured weights. Interrater reliabilities were excellent for starting portions and plate waste with digital imagery. For accuracy, intraclass correlations were moderate, with lower accuracy for determining starting portions of leafy greens compared with other vegetables. However, accuracy of digital imagery-assessed plate waste was excellent. Digital imagery assessments were not significantly different from measured weights for estimating overall vegetable starting portions or waste; however, digital imagery assessments slightly underestimated starting portions (by 3.5 g) and waste (by 2.1 g) of leafy greens. This investigation provides preliminary support for use of digital imagery in estimating starting portions and plate waste from school salad bars. Results might inform

  6. Smoking synthetic marijuana leads to self-mutilation requiring bilateral amputations.

    Science.gov (United States)

    Meijer, Karim A; Russo, Russell R; Adhvaryu, Dhaval V

    2014-04-01

    Synthetic cannabinoids have become a worldwide epidemic because they provide a sometimes legal, easily accessible, and presumably safe alternative to marijuana. Recently published reports have linked acute psychosis, myocardial infarctions, convulsions, self-harm, and even terrorist organizations to these designer substances. This case report outlines the first reported case of Black Diamond, a synthetic cannabis, leading to a self-inflicted burn to the bilateral upper extremities requiring a transradial amputation of the right arm and a toe transfer procedure of the left hand after loss of all digits. The patient presented to the emergency department with self-inflicted fourth-degree burns to the bilateral hands and forearms with second-degree burns of the face, for a total body surface area of 14.5%. The patient was found by firefighters with his hands aflame on his kitchen stove. With no previous medical or psychiatric history and collateral information to confirm the patient's mental status prior to use of Black Diamond, the patient's acute psychotic episode was attributed to Black Diamond. After multiple procedures and a lengthy recovery, the patient completed his post-graduate education and entered the professional world. As orthopedic surgeons, we should be involved in educating the public on the harm of these designer drugs, including self-mutilation. The popularity of synthetic drugs in the United States will continue to present a major challenge to all health care providers. Orthopedists are on the front lines of this epidemic because these drugs push patients into risky, traumatic behavior. Copyright 2014, SLACK Incorporated.

  7. Bilateral locked facets in the thoracic spine

    NARCIS (Netherlands)

    M.H.A. Willems; Braakman, R. (Reinder); B. van Linge (Bert)

    1984-01-01

    textabstractTwo cases of traumatic bilateral locked facets in the thoracic spine are reported. Both patients had only minor neurological signs. They both made a full neurological recovery after surgical reduction of the locked facets. Bilateral locked facets are very uncommon in the thoracic spine.

  8. Effective x-ray attenuation measurements with full field digital mammography

    International Nuclear Information System (INIS)

    Heine, John J.; Behera, Madhusmita

    2006-01-01

    This work shows that effective x-ray attenuation coefficients may be estimated by applying Beer's Law to phantom image data acquired with the General Electric Senographe 2000D full field digital mammography system. Theoretical developments are provided indicating that an approximate form of the Beer's relation holds for polychromatic x-ray beams. The theoretical values were compared with experimentally determined measured values, which were estimated at various detector locations. The measured effective attenuation coefficients are in agreement with those estimated with theoretical developments and numerical integration. The work shows that the measured quantities show little spatial variation. The main ideas are demonstrated with polymethylmethacrylate and breast tissue equivalent phantom imaging experiments. The work suggests that the effective attenuation coefficients may be used as known values for radiometric standardization applications that compensate for the image acquisition influences. The work indicates that it is possible to make quantitative attenuation coefficient measurements from a system designed for clinical purposes

  9. Fibromuscular Dysplasia Presenting with Bilateral Renal Infarction

    International Nuclear Information System (INIS)

    Doody, O.; Adam, W. R.; Foley, P. T.; Lyon, S. M.

    2009-01-01

    Fibromuscular dysplasia (FMD) describes a group of conditions which cause nonatheromatous arterial stenoses, most commonly of the renal and carotid arteries, typically in young women. We report a rare case of bilateral segmental renal infarction secondary to FMD in a young male patient. His initial presentation with loin pain and pyrexia resulted in a delay in the definitive diagnosis of FMD. He was successfully treated with bilateral balloon angioplasty. The delayed diagnosis in this patient until the condition had progressed to bilateral renal infarcts highlights the need for prompt investigation and diagnosis of suspected cases of FMD.

  10. A digital, constant-frequency pulsed phase-locked-loop instrument for real-time, absolute ultrasonic phase measurements

    Science.gov (United States)

    Haldren, H. A.; Perey, D. F.; Yost, W. T.; Cramer, K. E.; Gupta, M. C.

    2018-05-01

    A digitally controlled instrument for conducting single-frequency and swept-frequency ultrasonic phase measurements has been developed based on a constant-frequency pulsed phase-locked-loop (CFPPLL) design. This instrument uses a pair of direct digital synthesizers to generate an ultrasonically transceived tone-burst and an internal reference wave for phase comparison. Real-time, constant-frequency phase tracking in an interrogated specimen is possible with a resolution of 0.000 38 rad (0.022°), and swept-frequency phase measurements can be obtained. Using phase measurements, an absolute thickness in borosilicate glass is presented to show the instrument's efficacy, and these results are compared to conventional ultrasonic pulse-echo time-of-flight (ToF) measurements. The newly developed instrument predicted the thickness with a mean error of -0.04 μm and a standard deviation of error of 1.35 μm. Additionally, the CFPPLL instrument shows a lower measured phase error in the absence of changing temperature and couplant thickness than high-resolution cross-correlation ToF measurements at a similar signal-to-noise ratio. By showing higher accuracy and precision than conventional pulse-echo ToF measurements and lower phase errors than cross-correlation ToF measurements, the new digitally controlled CFPPLL instrument provides high-resolution absolute ultrasonic velocity or path-length measurements in solids or liquids, as well as tracking of material property changes with high sensitivity. The ability to obtain absolute phase measurements allows for many new applications than possible with previous ultrasonic pulsed phase-locked loop instruments. In addition to improved resolution, swept-frequency phase measurements add useful capability in measuring properties of layered structures, such as bonded joints, or materials which exhibit non-linear frequency-dependent behavior, such as dispersive media.

  11. Recurrent Bilateral Breast Abscesses after Sternotomy

    Directory of Open Access Journals (Sweden)

    Hamza Cinar

    2012-01-01

    Full Text Available Median sternotomy is the most commonly used incision in cardiothoracic procedures. Development of breast abscess after sternotomy is a very rare situation. We present a case of sternal wound infection with recurrent bilateral breast abscess after sternotomy. Our case is the first and only case in the literature due to the presence of sternal wound infection with recurrent bilateral breast abscess after sternotomy.

  12. Bilateral agreements

    International Nuclear Information System (INIS)

    Anon.

    2004-01-01

    The bilateral agreements concern Brazil with United States relative to the co operation in nuclear energy, Germany with Russian Federation relative to the elimination and disposal of nuclear weapons; The multilateral agreements concerns the signature of the Protocols to amend the Paris and Brussels Conventions, the multilateral nuclear environmental programme in the Russian Federation, the status of Conventions in the field of nuclear energy. (N.C.)

  13. Bilateral Simultaneous Macular Infarction with Spontaneous Visual ...

    African Journals Online (AJOL)

    To report the rare and dramatic event of bilateral macular infarction in a sickle cell hemoglobinopathy (SS genotype) patient, resulting in bilateral severe reduction in visual acuity. Without any intervention, the patient's vision gradually improved over the follow‑up period. Central visual field defects however persisted.

  14. Noise reduction with complex bilateral filter.

    Science.gov (United States)

    Matsumoto, Mitsuharu

    2017-12-01

    This study introduces a noise reduction technique that uses a complex bilateral filter. A bilateral filter is a nonlinear filter originally developed for images that can reduce noise while preserving edge information. It is an attractive filter and has been used in many applications in image processing. When it is applied to an acoustical signal, small-amplitude noise is reduced while the speech signal is preserved. However, a bilateral filter cannot handle noise with relatively large amplitudes owing to its innate characteristics. In this study, the noisy signal is transformed into the time-frequency domain and the filter is improved to handle complex spectra. The high-amplitude noise is reduced in the time-frequency domain via the proposed filter. The features and the potential of the proposed filter are also confirmed through experiments.

  15. Digital voltmeter

    International Nuclear Information System (INIS)

    Yohannes Kamadi; Soekarno.

    1976-01-01

    The electrical voltage measuring equipment with digital display has been made. This equipment uses four digits display with single polarity measurement and integrating system. Pulses from the oscillator will be counted and converted to the staircase voltages, and compared to the voltage measured. When the balance is already achieved, the pulse will appear at the comparator circuit. This pulse will be used to trigger univibrator circuit. The univibrator output is used as signal for stopping the counting, and when reading time T already stops, the counting system will be reset. (authors)

  16. Evaluating and measuring the value, use and impact of digital collections

    CERN Document Server

    Hughes, Lorna M

    2011-01-01

    Brings together a group of international experts to consider the following key issues: What is the role of digital resources in the research life cycle? Do the arts and humanities face a 'data deluge'? How are digital collections to be sustained over the long term? What is the role of digital collections in the 'digital economy'?

  17. Measurement of the traction force of biological cells by digital holography

    Science.gov (United States)

    Yu, Xiao; Cross, Michael; Liu, Changgeng; Clark, David C.; Haynie, Donald T.; Kim, Myung K.

    2011-01-01

    The traction force produced by biological cells has been visualized as distortions in flexible substrata. We have utilized quantitative phase microscopy by digital holography (DH-QPM) to study the wrinkling of a silicone rubber film by motile fibroblasts. Surface deformation and the cellular traction force have been measured from phase profiles in a direct and straightforward manner. DH-QPM is shown to provide highly efficient and versatile means for quantitatively analyzing cellular motility. PMID:22254175

  18. Measurement of proton-beam parameters by means of digital television diagnostic system

    International Nuclear Information System (INIS)

    Vazhenin, V.A.; Borovkov, S.D.; Evtikhiev, A.V.

    1992-01-01

    A method is described for measurement of the parameters of pulse-packet beams by means of a digital television diagnostic system. Results of tests of the system in measurement of the parameters of a proton beam with an energy of 1.35 GeV in the U-70 circular accelerator and results of measurements of the energy spectrum of the 30-MeV proton beam of the LU-30 linear accelerator are given. The possibility is shown of using the system to measure the integrated characteristics of an entire beam-pulse packet as well as the characteristics of individual pulses with a period of 60 msec. 6 refs., 4 figs., 1 tab

  19. EXERTIONAL RHABDOMYOLYSIS OF THE BILATERAL ADDUCTOR MAGNUS

    Directory of Open Access Journals (Sweden)

    Tolga Saka

    2007-12-01

    Full Text Available We present a case study of a person (63 year-old man, who has been using statins for 18 years, with rhabdomyolysis of the bilateral adductor muscles associated with strenuous and prolonged eccentric exercises (hiking in a hot environment. Clinical examination showed predominantly on the right side muscle swelling and palpational pain of the bilateral adductor muscle groups and bilateral tibial edema. His serum creatine kinase (CK level was 12218 IU/L. T2-weighted magnetic resonance (MR images showed a high signal intensity in the bilateral adductor muscles of the hip. The patient did not develop complications and returned to his previous performance level in 30 days following adequate hydration and resting of the affected muscles. Strenuous eccentric exercise should be avoided during the course of statin use and clinicians should be aware of present observations when considering the significance of acute CK elevations in patients on statin treatment

  20. Bilateral nasolabial cysts associated with recurrent dacryocystitis.

    Science.gov (United States)

    Kyrmizakis, Dionysios E; Lachanas, Vassilios A; Benakis, Antonios A; Velegrakis, George A; Aslanides, Ioannis M

    2005-05-01

    Nasolabial cysts are rare, nonodontogenic, soft-tissue, developmental cysts occurring inferior to the nasal alar region. They are thought to arise from remnants of the nasolacrimal ducts and they are frequently asymptomatic. We report a rare case of bilateral nasolabial cysts accompanied by bilateral chronic dacryocystitis. A 48-year-old woman suffering from bilateral chronic dacryocystitis was referred to our department for endonasal dacryocystorhinostomy. She had undergone external dacryocystorhinostomy on the left side a few years earlier. Physical examination and computed tomography scan revealed nasolabial cysts bilaterally inferior to the nasal alar region. The cysts were removed via a sublabial approach and endoscopic dacryocystorhinostomy was performed on the right side. Ten months after surgery, the patient was asymptomatic. There may be a correlation, due to embryological reasons, between the presence of nasolabial cysts and the presence of chronic dacryocystitis. Both can be corrected surgically, under the same anaesthesia, without visible scar formation.

  1. Digital Sensor Technology

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, Ken D. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Quinn, Edward L. [Technology Resources, Dana Point, CA (United States); Mauck, Jerry L. [Technology Resources, Dana Point, CA (United States); Bockhorst, Richard M. [Technology Resources, Dana Point, CA (United States)

    2015-02-01

    The nuclear industry has been slow to incorporate digital sensor technology into nuclear plant designs due to concerns with digital qualification issues. However, the benefits of digital sensor technology for nuclear plant instrumentation are substantial in terms of accuracy and reliability. This paper, which refers to a final report issued in 2013, demonstrates these benefits in direct comparisons of digital and analog sensor applications. Improved accuracy results from the superior operating characteristics of digital sensors. These include improvements in sensor accuracy and drift and other related parameters which reduce total loop uncertainty and thereby increase safety and operating margins. An example instrument loop uncertainty calculation for a pressure sensor application is presented to illustrate these improvements. This is a side-by-side comparison of the instrument loop uncertainty for both an analog and a digital sensor in the same pressure measurement application. Similarly, improved sensor reliability is illustrated with a sample calculation for determining the probability of failure on demand, an industry standard reliability measure. This looks at equivalent analog and digital temperature sensors to draw the comparison. The results confirm substantial reliability improvement with the digital sensor, due in large part to ability to continuously monitor the health of a digital sensor such that problems can be immediately identified and corrected. This greatly reduces the likelihood of a latent failure condition of the sensor at the time of a design basis event. Notwithstanding the benefits of digital sensors, there are certain qualification issues that are inherent with digital technology and these are described in the report. One major qualification impediment for digital sensor implementation is software common cause failure (SCCF).

  2. Continuous bilateral thoracic paravertebral blockade for analgesia after cardiac surgery: a randomised, controlled trial.

    Science.gov (United States)

    Lockwood, Geoff G; Cabreros, Leilani; Banach, Dorota; Punjabi, Prakash P

    2017-10-01

    Continuous bilateral thoracic paravertebral blockade has been used for analgesia after cardiac surgery, but its efficacy has never been formally tested. Fifty adult patients were enrolled in a double-blind, randomised, controlled study of continuous bilateral thoracic paravertebral infusion of 0.5% lidocaine (1 mg.kg -1 .hr -1 ) for analgesia after coronary surgery. Control patients received a subcutaneous infusion of lidocaine at the same rate through catheters inserted at the same locations as the study group. The primary outcome was morphine consumption at 48 hours using patient-controlled analgesia (PCA). Secondary outcomes included pain, respiratory function, nausea and vomiting. Serum lidocaine concentrations were measured on the first two post-operative days. There was no difference in morphine consumption or in any other outcome measure between the groups. Serum lidocaine concentrations increased during the study, with a maximum of 5.9 mg.l -1 . There were no adverse events as a consequence of the study. Bilateral paravertebral infusion of lidocaine confers no advantage over systemic lidocaine infusion after cardiac surgery. ISRCTN13424423 ( https://www.isrctn.com ).

  3. The behavioral implications of the bilateral gamma process

    Science.gov (United States)

    Xie, Haibin; Wang, Shouyang; Lu, Zudi

    2018-06-01

    Bilateral gamma process is widely used in risk management and asset pricing. However the behavioral implications of this process remain unknown. This paper investigates this problem for the first time within the framework of Tauchen and Pitts (1983). With the assumption that there are two types of traders in the market, the optimistic and the pessimistic, we find the bilateral gamma process can be derived from Walrasian equilibrium. This finding establishes the microstructure foundations for the bilateral gamma process.

  4. [Atypical etiology of rhinorrhea: spontaneous bilateral temporal encephalocele].

    Science.gov (United States)

    Lorente Muñoz, Asís; Lisbona Alquézar, María Pilar; González Martínez, Luis; Sevil Navarro, Jorge; Llorente Arenas, Eva María

    2012-01-01

    Spontaneous herniation of brain parenchyma through a dural and osseous defect in the temporal bone is a rare entity and a bilateral form is even more infrequent. It usually presents as an intermittent but persistent otorrhea. Manifestation as nose cerebrospinal fluid (CSF) leak is very uncommon. Our objective is presenting this unusual case report of a spontaneous bilateral encephalocele with a bilateral tegmen tympani defect. Copyright © 2010 Elsevier España, S.L. All rights reserved.

  5. Bilateral cerebellar activation in unilaterally challenged essential tremor

    Directory of Open Access Journals (Sweden)

    Marja Broersma

    2016-01-01

    Conclusions: Our results expand on previous findings of bilateral cerebellar involvement in ET. We have identified specific areas in the bilateral somatomotor regions of the cerebellum: lobules V, VI and VIII.

  6. Primary Rectal Adenocarcinoma Metastasizing to Bilateral Breast - a Rare Case Demonstrated by {sup 18}F-FDG PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Soundararajan, Ramya; Arora, Saurabh; Das, Chandan Jyoti; Roy, Maitrayee; Kumar, Rakesh; Bal, Chandrasekhar [All India Institute of Medical Sciences, New Delhi (India)

    2016-06-15

    A 22-year-old female presented with multiple painless bilateral breast masses for the past 2 months. On Further questioning she had hematochezia and constipation for three months. On digital rectal examination, thickening of rectal mucosa at 5 cm from the anal verge was found. On physical examination, multiple firm, non-tender, nodular lesions were found in bilateral breasts. Metastatic breast disease from extra mammary primaries is uncommon and it constitutes 0.5 - 6% of all breast malignancies. melanomas, lymphomas, leukemias, ands sarcomas are the most common malignancies causing breast metastases. Infrequently, carcinomas of the lung, stomach, ovary, liver, tonsil, pleura, pancreas, cervix, perineum, endometrium, bladder, carcinoid tumors and renal cell carcinomas can cause metastatic breast disease. Metastatic breast disease from colorectal cancer is characterised by disseminated metastatic disease and a poor prognosis. In this case, It was essential to distinguish between metastatic breast disease primary breast carcinoma to plan appropriate management. Because of its rare incidence and high index of clinical suspicion, appropriate radiological investigations and histopathology is essential for accurate diagnosis. {sup 18}F-FDG PET/CT, being a whole-body metabolic functional imaging modality, helped us determine the extent of the primary and metastatic disease. In view of disseminated metastases, the bilateral breast disease was also considered as metastatic involvement, Which was proven by histopathology.

  7. Bilateral calcaneal epiphysiolysis in a dog.

    Science.gov (United States)

    Font, J; Pèlach, M; Font, C; Cairo, J

    2013-01-01

    A case of bilateral calcaneal epiphysiolysis in a six-month-old female Dobermann Pinscher is described in this report. The absence of a traumatic event and the clinical, radiographic and histopathological abnormalities led us to the diagnosis of simultaneous bilateral epiphysiolysis of the calcaneus. A tension band and a type II transarticular external fixator were placed. The clinical signs were resolved only temporarily because of the gravity of the bone changes.

  8. Bilateral Ramsay Hunt syndrome in a diabetic patient

    Directory of Open Access Journals (Sweden)

    Goyal Amit

    2004-12-01

    Full Text Available Abstract Background Herpes zoster oticus accounts for about 10% cases of facial palsy, which is usually unilateral and complete and full recovery occurs in only about 20% of untreated patients. Bilateral herpes zoster oticus can sometime occur in immunocompromised patients, though incidence is very rare. Case presentation Diabetic male, 57 year old presented to us with bilateral facial palsy due to herpes zoster oticus. Patient was having bilateral mild to moderate sensorineural hearing loss. Patient was treated with appropriate metabolic control, anti-inflammatory drugs and intravenous acyclovir. Due to uncontrolled diabetes, glucocorticoids were not used in this patient. Significant improvement in hearing status and facial nerve functions were seen in this patient. Conclusions Herpes zoster causes severe infections in diabetic patients and can be a cause of bilateral facial palsy and bilateral Ramsay Hunt syndrome. Herpes zoster in diabetic patients should be treated with appropriate metabolic control, NSAIDS and intravenous acyclovir, which we feel should be started at the earliest. Glucocorticoids should be avoided in diabetic patients.

  9. Simultaneous bilateral laser therapy accelerates recovery after noise-induced hearing loss in a rat model

    Directory of Open Access Journals (Sweden)

    Jae-Hun Lee

    2016-07-01

    Full Text Available Noise-induced hearing loss is a common type of hearing loss. The effects of laser therapy have been investigated from various perspectives, including in wound healing, inflammation reduction, and nerve regeneration, as well as in hearing research. A promising feature of the laser is its capability to penetrate soft tissue; depending on the wavelength, laser energy can penetrate into the deepest part of the body without damaging non-target soft tissues. Based on this idea, we developed bilateral transtympanic laser therapy, which uses simultaneous laser irradiation in both ears, and evaluated the effects of bilateral laser therapy on cochlear damage caused by noise overexposure. Thus, the purpose of this research was to assess the benefits of simultaneous bilateral laser therapy compared with unilateral laser therapy and a control. Eighteen Sprague-Dawley rats were exposed to narrow-band noise at 115 dB SPL for 6 h. Multiple auditory brainstem responses were measured after each laser irradiation, and cochlear hair cells were counted after the 15th such irradiation. The penetration depth of the 808 nm laser was also measured after sacrifice. Approximately 5% of the laser energy reached the contralateral cochlea. Both bilateral and unilateral laser therapy decreased the hearing threshold after noise overstimulation in the rat model. The bilateral laser therapy group showed faster functional recovery at all tested frequencies compared with the unilateral laser therapy group. However, there was no difference in the endpoint ABR results or final hair cell survival, which was analyzed histologically.

  10. Bilateral Giant Retinal Tear and Sequential Vitrectomy.

    Science.gov (United States)

    Mustapha, Mushawiahti; Roufail Franzco, Edward

    2017-01-01

    To describe the excellent outcome of surgery for bilateral giant retinal tears (GRTs) with better options of endotamponade. This is a case report of a 62-year-old man who presented with bilateral GRTs and associated retinal detachment. The tear in the right eye was supero-temporal and silicone oil was used as an endotamponade. The tear in the left eye was infero-temporal and perfluorocarbon liquid was used as an endotamponade. The outcome at 6 months after surgery was excellent with visual acuities of 6/6 in both eyes. Improved availability of endotamponade agents allows repair of bilateral GRTs to be done at the same time, with good surgical outcomes.

  11. Measuring food intake with digital photography

    Science.gov (United States)

    The Digital Photography of Foods Method accurately estimates the food intake of adults and children in cafeterias. With this method, images of food selection and leftovers are quickly captured in the cafeteria. These images are later compared with images of 'standard' portions of food using computer...

  12. Bilateral tumors of the upper urothelium

    Directory of Open Access Journals (Sweden)

    Đokić Milan

    2006-01-01

    Full Text Available Introduction: The incidence of tumors of the upper urothelium is high in our country, apart from their relation to specific regions (BEN and PBEN and their frequent bilateralism. Bilateral forms are present in significant percentage and are followed, in most cases, by renal failure, which speaks in favor of conservative surgery, if possible. Objective: The aim of the study was to present epidemiological, pathoanatomical and clinical characteristics of bilateral tumors of the upper urothelium and evaluate the Results of their treatment. Method: Our retrospective study analyzed 12 patients with bilateral tumors of the upper urothelium who were treated in the period from 1992 to 1996, according to their epidemiological, clinical, pathoanatomical and pathohistological characteristics, type of surgical treatment and relevant success. Results: In the observed period, bilateral tumors of the upper urothelium were found in 8.2% of our patients. In the group of 12 patients, 5 females and 7 males, 11 cases were from the region of Balkan Endemic Nephropathy (BEN. Renal failure was recorded in high percentage (66%. Radical surgical treatment - total nephroureterectomy was performed in 9 kidney units, and conservative operation in 15 units. Relapse significantly depended on tumor stage and grade, not on type of surgical treatment in the majority of cases. Five-year survival was 58.33%; major cause of death was associated with further evolution of tumor, recurrence and tumor dissemination, respectively, while renal failure complications were the cause of death in one case. Conclusion: The success of treatment mainly depends on tumor stage and grade and not on type of surgical Method in conservative treatment, but renal failure and its complications are an important risk factor in these patients.

  13. Pathogenesis and prognosis of bilateral thalamic infarction

    International Nuclear Information System (INIS)

    Nakase, Taizen; Ogura, Naoko; Maeda, Tetsuya; Yamazaki, Takashi; Kameda, Tomoaki; Sato, Yuichi; Nagata, Ken

    2008-01-01

    Only a few reports have discussed the detailed clinical symptoms and pathogenesis of bilateral thalamic infarction. The thalamus is composed of different functional nuclei and supplied by vessels containing several variations from the main arteries, leading to difficulty in the precise evaluation of bilateral thalamic infarction. In the present study, we assessed the prognosis of bilateral thalamic infarction based on the distribution of stroke lesions. From among the consecutive ischemic stroke patients admitted to hospital between April 2001 and March 2005, cases of acute bilateral thalamic infarction were selected for this study (n=9; 65.1±13.6 y.o.). The stroke lesions and vascular abnormalities were investigated by magnetic resonance imaging and magnetic resonance angiography on admission. Outcome was evaluated from the modified Rankin scale (mRS) at discharge. Good outcome patients (mRS 0-2; n=5) showed memory disturbance, cognitive impairment and hypersomnia. On the other hand, quadriplegia, oculomotor disturbance and bulbar palsy were observed in the poor outcome patients (mRS≥4; n=4). The critical features of a poor outcome were the age at onset (72.0±15.3 vs. 58.2±11.9 y.o.), inclusion of brainstem lesions and total occlusion of the basilar artery. In conclusion, older age at onset and/or basilar artery occlusion may be critical factors for predicting a poor outcome in bilateral thalamic infarction cases. (author)

  14. Danish Exports and Danish Bilateral Aid

    DEFF Research Database (Denmark)

    Hansen, Henrik; Rand, John

    higher in the 1980s compared to in particular the most recent decade. This may be related to factors such as untying of aid in the same period. The econometric analysis has two important limitations. First of all, the model can only give information about marginal changes in aid. As a decision to give...... and trade policies. The main result of the study is that Danish bilateral aid has a positive and statistically significant impact on Danish exports to the recipient countries. Bilateral development assistance may affect exports through several channels. Three of the main channels are direct aid tying......; increasing recipient income where higher income leads to higher imports, and decreased trade costs, say due to improved information about cultural and administrative customs and practices. Thus, as for preferential trade arrangements, bilateral aid has two potential economic effects; trade creation working...

  15. Bilateral movements increase sustained extensor force in the paretic arm.

    Science.gov (United States)

    Kang, Nyeonju; Cauraugh, James H

    2018-04-01

    Muscle weakness in the extensors poststroke is a common motor impairment. Unfortunately, research is unclear on whether bilateral movements increase extensor force production in the paretic arm. This study investigated sustained force production while stroke individuals maximally extended their wrist and fingers on their paretic arm. Specifically, we determined isometric force production in three conditions: (a) unilateral paretic arm, (b) unilateral nonparetic arm, and (c) bilateral (both arms executing the same movement simultaneously). Seventeen chronic stroke patients produced isometric sustained force by executing wrist and fingers extension in unilateral and bilateral contraction conditions. Mean force, force variability (coefficient of variation), and signal-to-noise ratio were calculated for each contraction condition. Analysis of two-way (Arm × Type of Condition: 2 × 2; Paretic or Nonparetic Arm × Unilateral or Bilateral Conditions) within-subjects ANOVAs revealed that the bilateral condition increased sustained force in the paretic arm, but reduced sustained force in the nonparetic arm. Further, although the paretic arm exhibited more force variability and less signal-to-noise ratio than the nonparetic arm during a unilateral condition, there were no differences when participants simultaneously executed isometric contractions with both arms. Our unique findings indicate that bilateral contractions transiently increased extensor force in the paretic arm. Implications for Rehabilitation Bilateral movements increased isometric wrsit extensor force in paretic arms and redcued force in nonparetic arms versus unilateral movements. Both paretic and nonparetic arms produced similar force variability and signal-to-noise ratio during bilateral movements. Increased sustained force in the paretic arm during the bilateral condition indicates that rehabilitation protocols based on bilateral movements may be beneficial for functional recovery.

  16. Coexistence of bilateral first and second branchial arch anomalies

    Science.gov (United States)

    Thakur, J S; Shekar, Vidya; Saluja, Manika; Mohindroo, N K

    2013-01-01

    Branchial arch anomalies are one of the most common congenital anomalies that are usually unilateral and bilateral presentation is rare. The simultaneous presence of bilateral second branchial arch anomalies along with bilateral first arch anomalies is extremely rare, with only three such cases reported in the literature. We present two non-syndromic cases of coexisting bilateral first and second arch anomalies. Developmental anomalies of the branchial apparatus account for 17% of all paediatric cervical masses and are the most common type of congenital cervical mass. They usually present in the paediatric age group. About 96–97% of these anomalies are unilateral. Bilateral presentation is seen in 2–3% having a strong familial association. Congenital syndromes also have been associated with first and second branchial arch anomalies. Thorough clinical examination and investigations should be done to rule out these syndromes. PMID:23580675

  17. Bilateral Cochlear Implants in Infants: A New Approach—Nucleus Hybrid S12 Project

    Science.gov (United States)

    Gantz, Bruce J.; Dunn, Camille C.; Walker, Elizabeth A.; Kenworthy, Maura; Van Voorst, Tanya; Tomblin, Bruce; Turner, Chris

    2010-01-01

    Objective The purpose of this feasibility study was to evaluate whether the use of a shorter-length cochlear implant (10 mm) on one ear and a standard electrode (24 mm) on the contralateral ear is a viable bilateral option for children with profound bilateral sensorineural hearing loss. A secondary purpose of this study was to determine whether the ear with the shorter-length electrode performs similarly to the standard-length electrode. Our goal was to provide an option of electrical stimulation that theoretically might preserve the structures of the scala media and organ of Corti. Study Design The study is being conducted as a repeated-measure, single-subject experiment. Setting University of Iowa—Department of Otolaryngology. Patients Eight pediatric patients with profound bilateral sensorineural hearing loss between the ages of 12 and 24 months. Interventions Nucleus Hybrid S12 10-mm electrode and a Nucleus Freedom implant in the contralateral ear. Main Outcome Measures The Infant-Toddler Meaningful Auditory Integration Scale (IT-MAIS) parent questionnaire, Early Speech Perception, Glendonald Auditory Screening Procedure word test, and Children’s Vowel tests will be used to evaluate speech perception and the Minnesota Child Development Inventory and Preschool Language Scales 3 test will be used to evaluate language growth. Results Preliminary results for 8 children have been collected before and after the operation using the IT-MAIS. All 3 children showed incremental improvements in their IT-MAIS scores overtime. Early Speech Perception, Glendonald Auditory Screening Procedure word test, and Children’s Vowel word perception results indicated no difference between the individual ears for the 2 children tested. Performance compared with age-matched children implanted with standard bilateral cochlear implants showed similar results to the children implanted with Nucleus Hybrid S12 10-mm electrode and a Nucleus Freedom implant in contralateral ears

  18. Associations of unilateral whisker and olfactory signals induce synapse formation and memory cell recruitment in bilateral barrel cortices: cellular mechanism for unilateral training toward bilateral memory

    Directory of Open Access Journals (Sweden)

    Zilong Gao

    2016-12-01

    Full Text Available Somatosensory signals and operative skills learned by unilateral limbs can be retrieved bilaterally. In terms of cellular mechanism underlying this unilateral learning toward bilateral memory, we hypothesized that associative memory cells in bilateral cortices and synapse innervations between them were produced. In the examination of this hypothesis, we have observed that paired unilateral whisker and odor stimulations led to odorant-induced whisker motions in bilateral sides, which were attenuated by inhibiting the activity of barrel cortices. In the mice that showed bilateral cross-modal responses, the neurons in both sides of barrel cortices became to encode this new odor signal alongside the innate whisker signal. Axon projections and synapse formations from the barrel cortex, which was co-activated with the piriform cortex, toward its contralateral barrel cortex were upregulated. Glutamatergic synaptic transmission in bilateral barrel cortices was upregulated and GABAergic synaptic transmission was downregulated. The associative activations of the sensory cortices facilitate new axon projection, glutamatergic synapse formation and GABAergic synapse downregulation, which drive the neurons to be recruited as associative memory cells in the bilateral cortices. Our data reveals the productions of associative memory cells and synapse innervations in bilateral sensory cortices for unilateral training toward bilateral memory.

  19. Spontaneous Unruptured Bilateral Tubal Pregnancy: A Case Report

    Directory of Open Access Journals (Sweden)

    Nayereh Ghomian

    2015-11-01

    Full Text Available Bilateral spontaneous tubal ectopic pregnancy is the rarest form of extra uterine pregnancy. The diagnosis is usually made intraoperatively and levels of serum BHCG and ultrasound has not been useful in the diagnosis of bilateral tubal ectopic pregnancy. A 33-year-old woman with 8 weeks amenorrhea and sever lower abdominal pain was admitted. A transvaginal pelvic ultrasound revealed left adnexal mass and massive fluid collection in the pelvis and abdomen. The serum BHCG was 5,700 mIU/ml and in laparotomy bilateral unruptured tubal pregnancy was noted. Left salpingectomy and right salpingostomy were performed. The diagnosis of bilateral spontaneous tubal ectopic pregnancy is usually made intraoperatively. Both tubes at the time of surgery should be closely examined in order to prevent maternal morbidity and mortality.

  20. Delayed-onset bilateral abducens paresis after head trauma

    Directory of Open Access Journals (Sweden)

    Pravin Salunke

    2012-01-01

    Full Text Available Bilateral sixth nerve paresis following closed head injury, though rare, is a known entity. However, delayed-onset post-traumatic bilateral abducens paresis is extremely rare. We present two cases. The first patient had onset of bilateral abducens paresis 2 weeks after closed head injury and the second patient after 3 days. The cause in the former was detected to be chronic subdural hematoma and in the latter is speculated to be edema/ischemia due to injury to soft tissue structures housing these nerves. The delayed onset of bilateral abducens paresis following head injury may vary according to the cause. There may be another mechanism of injury apart from direct trauma. Though rare, it needs to be evaluated and may have a treatable cause like elevated intracranial pressure.

  1. A digital method for period measurements in a nuclear reactor; Um metodo digital para medidas de periodo em um reator nuclear

    Energy Technology Data Exchange (ETDEWEB)

    Mundim, Sergio Gorretta

    1971-02-15

    The present paper begins by giving a theoretical treatment for the nuclear reactor period. The conventional method of measuring the period is analysed and some previously developed digital methods are described. The paper criticises the latter, pointing out some deficiencies which the proposed process is able to eliminate. All errors connected with this process are also analysed. The paper presents suitable solutions to reduce them to a minimum. The total error is found to he less than the error presented by the other methods described. A digital period meter is designed with memory resources and an automatic scaler changer. Integrated circuits specifications are used in it. Real time experiments with nuclear reactors were made in order to check te validity of the method. The data acquired were applied to a simulated digital period meter implemented in a general purpose computer. The nuclear part of the work was developed at the 'Comissao Nacional de Energia Nuclear' and the simulation work was dane at the 'Departamento de Calculo Cientifico' of COPPE, which also advised the author in the completion of this thesis. (author)

  2. Diffusion MR Imaging of Postoperative Bilateral Acute Ischemic Optic Neuropathy

    International Nuclear Information System (INIS)

    Park, Ju Young; Lee, In Ho; Song, Chang June; Hwang, Hee Youn

    2012-01-01

    A 57-year-old woman experienced bilateral acute ischemic optic neuropathy after spine surgery. Routine MR imaging sequence, T2-weighted image, showed subtle high signal intensity on bilateral optic nerves. A contrast-enhanced T1 weighted image showed enhancement along the bilateral optic nerve sheath. Moreover, diffusion-weighted image (DWI) and an apparent diffusion coefficient map showed markedly restricted diffusion on bilateral optic nerves. Although MR findings of T2-weighted and contrast enhanced T1-weighted images may be nonspecific, the DWI finding of cytotoxic edema of bilateral optic nerves will be helpful for the diagnosis of acute ischemic optic neuropathy after spine surgery.

  3. Diffusion MR Imaging of Postoperative Bilateral Acute Ischemic Optic Neuropathy

    Energy Technology Data Exchange (ETDEWEB)

    Park, Ju Young; Lee, In Ho; Song, Chang June [Chungnam National University Hospital, Daejeon (Korea, Republic of); Hwang, Hee Youn [Eulji University Hospital, Daejeon(Korea, Republic of)

    2012-03-15

    A 57-year-old woman experienced bilateral acute ischemic optic neuropathy after spine surgery. Routine MR imaging sequence, T2-weighted image, showed subtle high signal intensity on bilateral optic nerves. A contrast-enhanced T1 weighted image showed enhancement along the bilateral optic nerve sheath. Moreover, diffusion-weighted image (DWI) and an apparent diffusion coefficient map showed markedly restricted diffusion on bilateral optic nerves. Although MR findings of T2-weighted and contrast enhanced T1-weighted images may be nonspecific, the DWI finding of cytotoxic edema of bilateral optic nerves will be helpful for the diagnosis of acute ischemic optic neuropathy after spine surgery.

  4. The influence of the group delay of digital filters on acoustic decay measurements

    DEFF Research Database (Denmark)

    Sobreira-Seoane, Manuel A.; Cabo, David Pérez; Jacobsen, Finn

    2012-01-01

    In this paper the error due to the phase response of digital filters on acoustic decay measurements is analyzed. There are two main sources of errors when an acoustic decay is filtered: the error due to the bandwidth of the filters related to their magnitude response, and the error due to their p...

  5. Bilateral anophthalmia with septo-optic dysplasia

    OpenAIRE

    Jana, Manisha; Sharma, Sanjay

    2010-01-01

    Bilateral anophthalmia is a rare entity and association with septo-optic dysplasia is an even rare condition. The condition is characterized by absent eyeballs in the presence of eyelids, conjunctiva or lacrimal apparatus. Though anophthalmia can be diagnosed clinically, imaging plays a crucial role in delineating the associated anomalies. In addition, often clinical anophthalmia may prove to be severe microphthalmia on imaging. We describe the imaging findings in an infant with bilateral ano...

  6. Bilateral spontaneous adrenal haemorrhage complicating acute pancreatitis

    International Nuclear Information System (INIS)

    Pianta, M.; Varma, D. K.

    2007-01-01

    Bilateral adrenal haemorrhage is an event that mandates prompt diagnosis and treatment to prevent primary adrenocortical insufficiency and potential death. Presentation can be non-specific and incidentally diagnosed with imaging alone, primarily CT. We present a case of acute pancreatitis with spontaneous bilateral adrenal haemorrhage and briefly discuss imaging and treatment implications

  7. A Novel Sub-pixel Measurement Algorithm Based on Mixed the Fractal and Digital Speckle Correlation in Frequency Domain

    Directory of Open Access Journals (Sweden)

    Zhangfang Hu

    2014-10-01

    Full Text Available The digital speckle correlation is a non-contact in-plane displacement measurement method based on machine vision. Motivated by the facts that the low accuracy and large amount of calculation produced by the traditional digital speckle correlation method in spatial domain, we introduce a sub-pixel displacement measurement algorithm which employs a fast interpolation method based on fractal theory and digital speckle correlation in frequency domain. This algorithm can overcome either the blocking effect or the blurring caused by the traditional interpolation methods, and the frequency domain processing also avoids the repeated searching in the correlation recognition of the spatial domain, thus the operation quantity is largely reduced and the information extracting speed is improved. The comparative experiment is given to verify that the proposed algorithm in this paper is effective.

  8. Simultaneous bilateral patellar tendon rupture.

    Science.gov (United States)

    Moura, Diogo Lino; Marques, José Pedro; Lucas, Francisco Manuel; Fonseca, Fernando Pereira

    2017-01-01

    Bilateral patellar tendon rupture is a rare entity, often associated with systemic diseases and patellar tendinopathy. The authors report a rare case of a 34-year-old man with simultaneous bilateral rupture of the patellar tendon caused by minor trauma. The patient is a retired basketball player with no past complaints of chronic knee pain and a history of steroid use. Surgical management consisted in primary end-to-end tendon repair protected temporarily with cerclage wiring, followed by a short immobilization period and intensive rehabilitation program. Five months after surgery, the patient was able to fully participate in sport activities.

  9. Measurement of radiation dose to the eye-lens with bilateral whole brain irradiation

    International Nuclear Information System (INIS)

    Kim, Ki Hwan; Park, Charn Il; Kang, Wee Saing; Choo, Dong Woon

    1985-01-01

    In 40 patients with metastatic brain tumor and acute lymphoblastic leukemia received whole brain irradiation, the dose delivered to the eye lens was measured using T.L.D. chips applied on the eyes as usual shield. The dose to the eye lens was expressed the relative dose to the mid brain dose. Radiotherapy was administrated using Co-60 teletherapy with bilateral whole brain irradiation. The results are as follows: 1. The dose to the right eye from its incipient field is 16.6% of tumor dose while the dose to the same eye from the opposite field is 41.2%. On left eye, 19.2% from incipient field while 39.2% from the opposite field. 2. Total received dose to right and left eyes is 28.9%, 29.8% of tumor dose respectively. 3. Comparing lens shield group with orbit shield group dose is 22.5%, 15.8% of tumor dose, respectively. 4. The dose delivered to the eye lens in ipsilateral side depends upon internal scattering, location of lead shield and penetrating dose of lead in itself. The dose in contralateral side depends upon divergency of radiation beam and patient's malposition. 5. The dose to the eye lens should be less than 10% of tumor dose with adequate shield, also not missing the chance of leptomeningeal recurrence because of overshielding.

  10. Dacrioadenite bilateral causada pelo vírus Epstein-Barr: relato de caso Epstein-Barr virus bilateral dacryoadenitis: case report

    Directory of Open Access Journals (Sweden)

    Bernardo Kaplan Moscovici

    2009-12-01

    Full Text Available Os autores apresentam um caso raro de dacrioadenite aguda bilateral associada à mononucleose. Paciente do sexo feminino, 27 anos, tinha aumento agudo da glândula lacrimal, bilateral, com sinais flogísticos. As alterações tomográficas e laboratoriais confirmaram o diagnóstico e o tratamento com esteróide sistêmico foi introduzido, com resolução completa dos sinais e sintomas. COMENTÁRIOS: A dacrioadenite é uma apresentação incomum da mononucleose infecciosa e pode minimizar outras manifestações desta doença. O diagnóstico de mononucleose deve ser considerado em casos de dacrioadenite aguda bilateral. Os esteróides sistêmicos contribuem para a resolução do quadro inflamatório.The authors present a rare case of acute bilateral dacryoadenitis in association with infectious mononucleosis. A 27 year-old woman had acute bilateral lacrimal gland enlargement with inflammatory signs. The CT scan findings and laboratorial investigations confirmed the diagnosis of infectious mononucleosis. The systemic treatment with intravenous steroids was initiated leading to complete remission of the signs and symptoms. COMMENTS: Dacryoadenitis is an uncommon manifestation of infectious mononucleosis and may minimize other signs of the disease. Mononucleosis has to be considered in acute dacryoadenitis cases. Systemic steroids contribute to the fast regression of inflammatory condition.

  11. Advanced measurement systems based on digital processing techniques for superconducting LHC magnets

    CERN Document Server

    Masi, Alessandro; Cennamo, Felice

    The Large Hadron Collider (LHC), a particle accelerator aimed at exploring deeper into matter than ever before, is currently being constructed at CERN. Beam optics of the LHC, requires stringent control of the field quality of about 8400 superconducting magnets, including 1232 main dipoles and 360 main quadrupoles to assure the correct machine operation. The measurement challenges are various: accuracy on the field strength measurement up to 50 ppm, harmonics in the ppm range, measurement equipment robustness, low measurement times to characterize fast field phenomena. New magnetic measurement systems, principally based on analog solutions, have been developed at CERN to achieve these goals. This work proposes the introduction of digital technologies to improve measurement performance of three systems, aimed at different measurement target and characterized by different accuracy levels. The high accuracy measurement systems, based on rotating coils, exhibit high performance in static magnetic field. With vary...

  12. Easy Leaf Area: Automated Digital Image Analysis for Rapid and Accurate Measurement of Leaf Area

    Directory of Open Access Journals (Sweden)

    Hsien Ming Easlon

    2014-07-01

    Full Text Available Premise of the study: Measurement of leaf areas from digital photographs has traditionally required significant user input unless backgrounds are carefully masked. Easy Leaf Area was developed to batch process hundreds of Arabidopsis rosette images in minutes, removing background artifacts and saving results to a spreadsheet-ready CSV file. Methods and Results: Easy Leaf Area uses the color ratios of each pixel to distinguish leaves and calibration areas from their background and compares leaf pixel counts to a red calibration area to eliminate the need for camera distance calculations or manual ruler scale measurement that other software methods typically require. Leaf areas estimated by this software from images taken with a camera phone were more accurate than ImageJ estimates from flatbed scanner images. Conclusions: Easy Leaf Area provides an easy-to-use method for rapid measurement of leaf area and nondestructive estimation of canopy area from digital images.

  13. Sarcoidosis Presenting as Bilateral Vocal Fold Immobility.

    Science.gov (United States)

    Hintze, Justin M; Gnagi, Sharon H; Lott, David G

    2018-05-01

    Bilateral true vocal fold paralysis is rarely attributable to inflammatory diseases. Sarcoidosis is a rare but important etiology of bilateral true vocal fold paralysis by compressive lymphadenopathy, granulomatous infiltration, and neural involvement. We describe the first reported case of sarcoidosis presenting as bilateral vocal fold immobility caused by direct fixation by granulomatous infiltration severe enough to necessitate tracheostomy insertion. In addition, we discuss the presentation, the pathophysiology, and the treatment of this disease with a review of the literature of previously reported cases of sarcoidosis-related vocal fold immobility. Sarcoidosis should therefore be an important consideration for the otolaryngologist's differential diagnosis of true vocal fold immobility. Copyright © 2018 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  14. Availability of binaural cues for pediatric bilateral cochlear implant recipients.

    Science.gov (United States)

    Sheffield, Sterling W; Haynes, David S; Wanna, George B; Labadie, Robert F; Gifford, René H

    2015-03-01

    Bilateral implant recipients theoretically have access to binaural cues. Research in postlingually deafened adults with cochlear implants (CIs) indicates minimal evidence for true binaural hearing. Congenitally deafened children who experience spatial hearing with bilateral CIs, however, might perceive binaural cues in the CI signal differently. There is limited research examining binaural hearing in children with CIs, and the few published studies are limited by the use of unrealistic speech stimuli and background noise. The purposes of this study were to (1) replicate our previous study of binaural hearing in postlingually deafened adults with AzBio sentences in prelingually deafened children with the pediatric version of the AzBio sentences, and (2) replicate previous studies of binaural hearing in children with CIs using more open-set sentences and more realistic background noise (i.e., multitalker babble). The study was a within-participant, repeated-measures design. The study sample consisted of 14 children with bilateral CIs with at least 25 mo of listening experience. Speech recognition was assessed using sentences presented in multitalker babble at a fixed signal-to-noise ratio. Test conditions included speech at 0° with noise presented at 0° (S0N0), on the side of the first CI (90° or 270°) (S0N1stCI), and on the side of the second CI (S0N2ndCI) as well as speech presented at 0° with noise presented semidiffusely from eight speakers at 45° intervals. Estimates of summation, head shadow, squelch, and spatial release from masking were calculated. Results of test conditions commonly reported in the literature (S0N0, S0N1stCI, S0N2ndCI) are consistent with results from previous research in adults and children with bilateral CIs, showing minimal summation and squelch but typical head shadow and spatial release from masking. However, bilateral benefit over the better CI with speech at 0° was much larger with semidiffuse noise. Congenitally deafened

  15. Bilateral chronic subdural hematoma

    DEFF Research Database (Denmark)

    Andersen-Ranberg, Nina Christine; Rom Poulsen, Frantz; Bergholt, Bo

    2017-01-01

    OBJECTIVE Bilateral chronic subdural hematoma (bCSDH) is a common neurosurgical condition frequently associated with the need for retreatment. The reason for the high rate of retreatment has not been thoroughly investigated. Thus, the authors focused on determining which independent predictors...... are associated with the retreatment of bCSDH with a focus on surgical laterality. METHODS In a national database of CSDHs (Danish Chronic Subdural Hematoma Study) the authors retrospectively identified all bCSDHs treated in the 4 Danish neurosurgical departments over the 3-year period from 2010 to 2012...... that a separated hematoma density and the absence of postoperative drainage were independent predictors of retreatment. CONCLUSIONS In bCSDHs bilateral surgical intervention significantly lowers the risk of retreatment compared with unilateral intervention and should be considered when choosing a surgical...

  16. DIMOND II: Measures for optimising radiological information content and dose in digital imaging

    International Nuclear Information System (INIS)

    Dowling, A.; Malone, J.; Marsh, D.

    2001-01-01

    The European Commission concerted action on 'Digital Imaging: Measures for Optimising Radiological Information Content and Dose', DIMOND II, was conducted by 12 European partners over the period January 1997 to June 1999. The objective of the concerted action was to initiate a project in the area of digital medical imaging where practice was evolving without structured research in radiation protection, optimisation or justification. The main issues addressed were patient and staff dosimetry, image quality, quality criteria and technical issues. The scope included computed radiography (CR), image intensifier radiography and fluoroscopy, cardiology and interventional procedures. The concerted action was based on the consolidation of work conducted in the partner's institutions together with elective new work. Protocols and approaches to dosimetry, radiological information content/image quality measurement and quality criteria were established and presented at an international workshop held in Dublin in June 1999. Details of the work conducted during the DIMOND II concerted action and a summary of the main findings and conclusions are presented in this contribution. (author)

  17. Recommendations for certification or measurement of reliability for reliable digital archival repositories with emphasis on access

    Directory of Open Access Journals (Sweden)

    Paula Regina Ventura Amorim Gonçalez

    2017-04-01

    Full Text Available Introduction: Considering the guidelines of ISO 16363: 2012 (Space data and information transfer systems -- Audit and certification of trustworthy digital repositories and the text of CONARQ Resolution 39 for certification of Reliable Digital Archival Repository (RDC-Arq, verify the technical recommendations should be used as the basis for a digital archival repository to be considered reliable. Objective: Identify requirements for the creation of Reliable Digital Archival Repositories with emphasis on access to information from the ISO 16363: 2012 and CONARQ Resolution 39. Methodology: For the development of the study, the methodology consisted of an exploratory, descriptive and documentary theoretical investigation, since it is based on ISO 16363: 2012 and CONARQ Resolution 39. From the perspective of the problem approach, the study is qualitative and quantitative, since the data were collected, tabulated, and analyzed from the interpretation of their contents. Results: We presented a set of Checklist Recommendations for reliability measurement and/or certification for RDC-Arq with a clipping focused on the identification of requirements with emphasis on access to information is presented. Conclusions: The right to information as well as access to reliable information is a premise for Digital Archival Repositories, so the set of recommendations is directed to archivists who work in Digital Repositories and wish to verify the requirements necessary to evaluate the reliability of the Digital Repository or still guide the information professional in collecting requirements for repository reliability certification.

  18. Mobile measurement setup according to IEC 62220-1-2 for DQE determination on digital mammography systems

    Science.gov (United States)

    Greiter, Matthias B.; Hoeschen, Christoph

    2010-04-01

    The international standard IEC 62220-1-2 defines the measurement procedure for determination of the detective quantum efficiency (DQE) of digital x-ray imaging devices used in mammography. A mobile setup complying to this standard and adaptable to most current systems was constructed in the Helmholtz Zentrum München to allow for an objective technical comparison of current full field digital mammography units employed in mammography screening in Germany. This article demonstrates the setup's capabilities with a focus on the measurement uncertainties of all quantities contributing to DQE measurements. Evaluation of uncertainties encompasses results from measurements on a Sectra Microdose Mammography in clinical use, as well as on a prototype of a Fujifilm Amulet system at various radiation qualities. Both systems have a high spatial resolution of 50 μm × 50 μm. The modulation transfer function (MTF), noise power spectrum (NPS) and DQE of the Sectra MDM are presented in comparison to results previously published by other authors.

  19. Nanoscale displacement measurement by a digital nano-moire method with wavelet transformation

    International Nuclear Information System (INIS)

    Liu, C-M; Chen, L-W; Wang, C-C

    2006-01-01

    A digital nano-moire method with wavelet transformation is explored to measure nanoscale in-plane displacement fields. By applying e-beam lithography, a periodic PMMA nanostructure array is fabricated directly on the specimen and used as the specimen grating. Moire patterns are generated by overlapping the images of the PMMA specimen grating obtained from AFM scanning and the virtual reference grating produced by a digital image generating process. Then, the overlapped images are filtered by the 2D wavelet transformation (WT) to capture the target moire patterns. Existing methods, by overlapping the monitor-generated scanning lines with the image of the specimen grating, cause a mismatch problem. Previously, the carrier moire method was explored with the aim of curing the mismatch problem. Unfortunately, the carrier moire method, in addition to suffering from increased complexity of mathematical calculations, is incapable of directly obtaining the displacement field. Thus, the mismatch problem will result in inconveniences and restrictions in the practical application. Instead of using monitor-generated scanning lines, the proposed method applies the virtual reference grating, and thus puts the mismatch problem to rest. Nevertheless, the resultant moire image suffers from low contrast which, if left untreated, might distort the measurement result. Therefore, the WT, known for its sharpened abilities of characteristic and edge detection, is used to capture the target moire patterns and improve the measurement accuracy. The proposed method has been carried out in the laboratory. Experimental results have shown that the proposed method is convenient and efficient for nanoscale displacement measurement

  20. Derivation and Cross-Validation of Cutoff Scores for Patients With Schizophrenia Spectrum Disorders on WAIS-IV Digit Span-Based Performance Validity Measures.

    Science.gov (United States)

    Glassmire, David M; Toofanian Ross, Parnian; Kinney, Dominique I; Nitch, Stephen R

    2016-06-01

    Two studies were conducted to identify and cross-validate cutoff scores on the Wechsler Adult Intelligence Scale-Fourth Edition Digit Span-based embedded performance validity (PV) measures for individuals with schizophrenia spectrum disorders. In Study 1, normative scores were identified on Digit Span-embedded PV measures among a sample of patients (n = 84) with schizophrenia spectrum diagnoses who had no known incentive to perform poorly and who put forth valid effort on external PV tests. Previously identified cutoff scores resulted in unacceptable false positive rates and lower cutoff scores were adopted to maintain specificity levels ≥90%. In Study 2, the revised cutoff scores were cross-validated within a sample of schizophrenia spectrum patients (n = 96) committed as incompetent to stand trial. Performance on Digit Span PV measures was significantly related to Full Scale IQ in both studies, indicating the need to consider the intellectual functioning of examinees with psychotic spectrum disorders when interpreting scores on Digit Span PV measures. © The Author(s) 2015.

  1. A Case of Synchronous Bilateral Upper Urinary System Urothelial Carcinoma

    Directory of Open Access Journals (Sweden)

    Ibrahim Buldu

    2014-12-01

    Full Text Available Synchronous bilateral upper urinary tract urothelial cancer (UTUC is a very rare form of urothelial cancer. In patients with high-risk unilateral UTUC, radical nephroureterectomy (RNU is the gold standard treatment. However, there is no consensus on the treatment for synchronous bilateral UTUC. Evaluation of the patient and the tumor is recommended. Bilateral nephron-sparing surgery (NSS was performed on a 53-year-old patient who presented with high-risk synchronous bilateral UTUC, and the outcome was reported.

  2. IgG4-Related Disease of Bilateral Temporal Bones.

    Science.gov (United States)

    Li, Lilun; Ward, Bryan; Cocks, Margaret; Kheradmand, Amir; Francis, Howard W

    2017-03-01

    IgG4-related disease (IgG4-RD) is an idiopathic inflammatory condition that causes pseudotumor formation in single or multiple organs, including those of the head and neck. Temporal bone involvement is rare, with only 3 cases of unilateral temporal bone IgG4-RD described in the literature. We report the first known case of IgG4-RD of bilateral temporal bones and describe its clinical presentation, diagnosis, and treatment. The patient was a 52-year-old man with latent tuberculosis (TB) who presented with a 10-year history of bilateral profound hearing loss and vestibular dysfunction. Computed tomography and magnetic resonance imaging demonstrated bilateral labyrinthine destruction with invasion of the posterior fossa. Immunoglobulin level testing showed elevated total serum IgG levels with normal IgG4 levels. Bilateral mastoidectomies were performed, with biopsy samples demonstrating IgG4 staining with IgG4-positive plasma cells up to 40/HPF (high power field) on the right and 20/HPF on the left, consistent with bilateral IgG4-RD. IgG4-RD of bilateral temporal bones presents with chronic and progressive bilateral hearing loss and vestibular dysfunction. Clinical presentation and radiologic findings are nonspecific, and definitive diagnosis must be made with histopathology and immunostaining. Corticosteroids are therapeutic, but surgical resection may be necessary for temporal bone IgG4-RD to improve long-term remission.

  3. Outcome of bilateral ureteroscopic retrieval of stones in a single session

    Directory of Open Access Journals (Sweden)

    Majid Mushtaque

    2012-01-01

    Conclusion: Bilateral same-session ureteroscopy is a safe and effective procedure in the management of bilateral ureteral stones. The results are comparable to unilateral or staged bilateral procedures.

  4. Essure insert expulsion after 3-month hysterosalpingogram confirmation of bilateral tubal occlusion and bilateral correct placement: case report.

    Science.gov (United States)

    Garcia, Amy L; Lewis, Rae M; Sloan, Anita Lee

    2013-01-01

    Essure hysteroscopic sterilization is an effective permanent contraception option for women, with a 99.83% effectiveness rate. To date, more than 600,000 Essure procedures have been performed worldwide. This case report describes bilateral Essure insert placement, after which the left insert was subsequently expelled after hysterosalpingogram (HSG)-confirmed correct bilateral insert placement and bilateral tubal occlusion. Although insert expulsion has been reported before a 3-month post-procedure HSG, this is the first published report of expulsion after a confirmatory 3-month post-procedure HSG. Because there now exists documentation of Essure insert expulsion after a 3-month confirmatory HSG, physicians and patients should be informed of this rare occurrence. Further investigation into the causes of such an event is warranted. Copyright © 2013 AAGL. Published by Elsevier Inc. All rights reserved.

  5. Effect of out-of-plane specimen movement on strain measurement using digital-image-correlation-based video measurement in 2D and 3D

    DEFF Research Database (Denmark)

    Poling, Joel; Desai, Niranjan; Fischer, Gregor

    2018-01-01

    This study determined the effect of specimen out-of-plane movement relative to the sensor, on the accuracy of strains measured made applying 2D and 3D measurement approaches employing the state-of-the-art digital-image-correlation (DIC)-based tool iMETRUM. DIC provides a convenient and inexpensive...

  6. Simultaneous bilateral patellar tendon rupture

    Directory of Open Access Journals (Sweden)

    Diogo Lino Moura

    Full Text Available ABSTRACT Bilateral patellar tendon rupture is a rare entity, often associated with systemic diseases and patellar tendinopathy. The authors report a rare case of a 34-year-old man with simultaneous bilateral rupture of the patellar tendon caused by minor trauma. The patient is a retired basketball player with no past complaints of chronic knee pain and a history of steroid use. Surgical management consisted in primary end-to-end tendon repair protected temporarily with cerclage wiring, followed by a short immobilization period and intensive rehabilitation program. Five months after surgery, the patient was able to fully participate in sport activities.

  7. Bilateral anophthalmia with septo-optic dysplasia

    Directory of Open Access Journals (Sweden)

    Manisha Jana

    2010-01-01

    Full Text Available Bilateral anophthalmia is a rare entity and association with septo-optic dysplasia is an even rare condition. The condition is characterized by absent eyeballs in the presence of eyelids, conjunctiva or lacrimal apparatus. Though anophthalmia can be diagnosed clinically, imaging plays a crucial role in delineating the associated anomalies. In addition, often clinical anophthalmia may prove to be severe microphthalmia on imaging. We describe the imaging findings in an infant with bilateral anophthalmia and septo-optic dysplasia.

  8. Digital Hadron Calorimetry

    Science.gov (United States)

    Bilki, Burak

    2018-03-01

    The Particle Flow Algorithms attempt to measure each particle in a hadronic jet individually, using the detector providing the best energy/momentum resolution. Therefore, the spatial segmentation of the calorimeter plays a crucial role. In this context, the CALICE Collaboration developed the Digital Hadron Calorimeter. The Digital Hadron Calorimeter uses Resistive Plate Chambers as active media and has a 1-bit resolution (digital) readout of 1 × 1 cm2 pads. The calorimeter was tested with steel and tungsten absorber structures, as well as with no absorber structure, at the Fermilab and CERN test beam facilities over several years. In addition to conventional calorimetric measurements, the Digital Hadron Calorimeter offers detailed measurements of event shapes, rigorous tests of simulation models and various tools for improved performance due to its very high spatial granularity. Here we report on the results from the analysis of pion and positron events. Results of comparisons with the Monte Carlo simulations are also discussed. The analysis demonstrates the unique utilization of detailed event topologies.

  9. The application of the bilateral collimator to parasternal lymphoscintigraphy: a new method to measure the depth of the lymph node

    International Nuclear Information System (INIS)

    Ohtake, E.; Toyama, H.; Iio, M.; Noguchi, M.; Kawaguchi, S.; Murata, H.; Chiba, K.; Yamada, H.

    1980-01-01

    The bilateral collimator has been widely adopted for obtaining two simultaneous views of the heart in nuclear cardiology. As an additional useful clinical application of the bilateral collimator, it has been used for parasternal lymphoscintigraphy. Lymphography with a contrast medium for the parasternal lymphatics is technically very difficult and the radionuclide method is adopted. Lymphoscintigraphy has been used in order to determine the existence of malignant invasion to the lymph nodes, and also to find the depth of the lymph node as a guide to operation and radiation therapy of the nodes. (author)

  10. Congenital bilateral neuroblastoma (stage IV-S): case report

    International Nuclear Information System (INIS)

    Lee, Jeong Hee; Lee, Hee Jung; Woo, Seong Ku; Lee, Sang Rak; Kim, Heung Sik

    2002-01-01

    Congenital neonatal neuroblastoma is not uncommon but bilateral adrenal neuroblastoma is rare, accounting for about ten percent of neuroblastomas in children. We report the US the MR findings of a stage IV-S congenital bilateral neuroblastoma occurring in a one-day-old neonate

  11. A case of bilateral vocal fold mucosal bridges, bilateral trans-vocal fold type III sulci vocales, and an intracordal polyp.

    Science.gov (United States)

    Tan, Melin; Pitman, Michael J

    2011-07-01

    We present a patient with a novel finding of bilateral mucosal bridges, bilateral type III trans-vocal fold sulci vocales, and a vocal fold polyp. Although sulci and mucosal bridges occur in the vocal folds, it is rare to find multiples of these lesions in a single patient, and it is even more uncommon when they occur in conjunction with a vocal fold polyp. To our knowledge, this is the first description of a vocal fold polyp in combination with multiple vocal fold bridges and multiple type III sulci vocales in a single patient. To describe and visually present the diagnosis and treatment of a patient with an intracordal polyp, bilateral mucosal bridges, as well as bilateral type III trans-vocal fold sulci vocales. Presentation of a set of high definition intraoperative photos displaying the extent of the vocal fold lesions and the resection of the intracordal polyp. This patient presented with only 6 months of significant dysphonia. It was felt that the recent change in voice was because of the polyp and not the bridges or sulci vocales. Considering the patient's presentation and the possible morbidity of resection of mucosal bridges and sulci, only the polyp was excised. Postoperatively, the patient's voice returned to his acceptable mild baseline dysphonia, and the benefit has persisted 6 months postoperatively. The combination of bilateral mucosal bridges, bilateral type III sulcus vocalis, and an intracordal polyp in one patient is rare if not novel. Treatment of the polyp alone returned the patient's voice to his lifelong baseline of mild dysphonia. Copyright © 2011 The Voice Foundation. Published by Mosby, Inc. All rights reserved.

  12. Functional recovery differences after stroke rehabilitation in patients with uni- or bilateral hemiparesis

    Science.gov (United States)

    Bindawas, Saad M.; Mawajdeh, Hussam M.; Vennu, Vishal S.; Alhaidary, Hisham M.

    2017-01-01

    Objective: To examine the functional recovery differences after stroke rehabilitation in patients with uni- or bilateral hemiparesis. Methods: In this retrospective study, we included data from the medical record of all 383 patients with uni- or bilateral hemiparesis after stroke who were admitted to King Fahad Medical City-Rehabilitation Hospital between 2008 and 2014 in Riyadh, Kingdom of Saudi Arabia. According to the site of hemiparesis, we classified patients into 3 groups: right hemiparesis (n=208), left hemiparesis (n=157), and bilateral hemipareses (n=18). The patients (n=49) who did not have either site of hemiparesis were excluded. The Functional Independence Measures (FIM) instrument was used to assess the score at admission and discharge. A post hoc test was conducted to examine the functional recovery differences between groups. Multiple regression analyses were used to confirm the findings. Results: Amongst the three groups, there were significant (phemiparesis group. Multiple regression analyses also confirmed that the site of hemiparesis significantly (phemiparesis after stroke. PMID:28678212

  13. Objective and subjective measures of simultaneous vs sequential bilateral cochlear implants in adults : A randomized clinical trial

    NARCIS (Netherlands)

    Kraaijenga, Véronique J.C.; Ramakers, Geerte G.J.; Smulders, Yvette E.; Van Zon, Alice; Stegeman, Inge; Smit, Adriana L.; Stokroos, Robert J.; Hendrice, Nadia; Free, Rolien H.; Maat, Bert; Frijns, Johan H M; Briaire, Jeroen J; Mylanus, Emmanuel A M; Huinck, Wendy J.; van Zanten, Gijsbert A.; Grolman, Wilko

    2017-01-01

    IMPORTANCE: To date, no randomized clinical trial on the comparison between simultaneous and sequential bilateral cochlear implants (BiCIs) has been performed.  OBJECTIVE: To investigate the hearing capabilities and the self-reported benefits of simultaneous BiCIs compared with those of sequential

  14. Objective and Subjective Measures of Simultaneous vs Sequential Bilateral Cochlear Implants in Adults: A Randomized Clinical Trial

    NARCIS (Netherlands)

    Kraaijenga, V.J.; Ramakers, G.G.; Smulders, Y.E.; Zon, A. van; Stegeman, I.; Smit, A.L.; Stokroos, R.J.; Hendrice, N.; Free, R.H.; Maat, B.; Frijns, J.H.; Briaire, J.J.; Mylanus, E.A.M.; Huinck, W.J.; Zanten, G.A.; Grolman, W.

    2017-01-01

    Importance: To date, no randomized clinical trial on the comparison between simultaneous and sequential bilateral cochlear implants (BiCIs) has been performed. Objective: To investigate the hearing capabilities and the self-reported benefits of simultaneous BiCIs compared with those of sequential

  15. Bi-lateral CO_2 emissions embodied in Australia–China trade

    International Nuclear Information System (INIS)

    Jayanthakumaran, Kankesu; Liu, Ying

    2016-01-01

    This paper quantifies the CO_2 emissions embodied in bi-lateral trade between Australia and China using a sectoral input–output model. The results revealed: (1) that China performs lower than Australia in clean technology in the primary, manufacturing, energy sectors due to their overuse of coal and inefficient sectoral production processes, and (2) that China had a 30.94 Mt surplus of bi-lateral CO_2 emissions in 2010–2011 and (3) overall global emissions were reduced by 20.19 Mt through Australia–China trade in 2010–2011. The result indicates that the greater the energy efficient a country among the trading partners the lower will be the overall global CO_2 emissions. Global emissions decreased mainly because China consumed Australian primary products rather than producing them. Australia is an energy efficient producer of primary products relative to China. The bilateral trade compositions and trade volume played an important role in lowering global emissions and therefore one can view proposed China Australia Free trade Agreement positively in reducing global emissions. However, for the sustainable development, China should strengthen clean energy use and both countries should adopt measures to create an emission trading scheme in order to avoid protectionism in the form of future border price adjustments. - Highlights: •Primary (Australia) and manufactured (China) exports are a unique combination. •Quantifies CO_2 emissions embodied in bi-lateral trade between Australia and China. •Global emissions reduce because China consume Australian primary. •Australia is energy efficient producer of primary products relative to China. •Results support more trade with appropriate trade composition and volume.

  16. Fibrovascular tissue in bilateral juxtafoveal telangiectasis.

    Science.gov (United States)

    Park, D; Schatz, H; McDonald, H R; Johnson, R N

    1996-09-01

    To study the natural history and retinal findings associated with the intraretinal and subretinal fibrovascular tissues that develop in the late phases of bilateral juxtafoveal telangiectasis. The records of 10 patients (11 eyes) with bilateral juxtafoveal telangiectasis who developed these fibrovascular tissues were examined. Throughout the follow-up period (average 44 months), only 2 eyes (18%) lost 2 or more lines of vision; the final visual acuities were similar for the eyes both with and without fibrovascular tissues. Sixty-four percent of fibrovascular tissues showed little to no growth. Eyes with fibrovascular tissue commonly had retinal pigment epithelial hyperplasia (72%), draining retinal venules (82%), and retinal vascular distortion (64%). Fibrovascular tissues of bilateral juxtafoveal telangiectasis have little proliferative potential and minimal effects on visual acuity. Nevertheless, these fibrovascular tissues do remodel over time, leading to retinal vascular distortion. Given these benign findings, the role of laser photocoagulation treatment of these tissues is questionable.

  17. Application of Digital Image Correlation to Measurement of Packaging Material Mechanical Properties

    Directory of Open Access Journals (Sweden)

    Jian-Wei Zhou

    2013-01-01

    Full Text Available Among various packaging materials, papers and polymer plastics are the most common due to their light weights, low costs, and other advantages. However, their mechanical properties are difficult to measure precisely because of their softness. To overcome the difficulty, a new measure instrument prototype is proposed based on an optical method known as the digital image correlation (DIC. Experiments are designed to apply the DIC to measure mechanical properties of flexible packaging materials, including the stress-strain relationship, the Poisson ratio, the coefficient of heat expansion, the creep deformation, and the top-pressure deformation of corrugated box. In addition, the low frequency vibration of package is simulated, and the vibration frequencies are measured by DIC. Results obtained in the experiments illustrate the advantages of the DIC over traditional methods: noncontact, no reinforced effect, high precision over entire area, wide measurement range, and good measurement stability.

  18. Binaural fusion and listening effort in children who use bilateral cochlear implants: a psychoacoustic and pupillometric study.

    Science.gov (United States)

    Steel, Morrison M; Papsin, Blake C; Gordon, Karen A

    2015-01-01

    Bilateral cochlear implants aim to provide hearing to both ears for children who are deaf and promote binaural/spatial hearing. Benefits are limited by mismatched devices and unilaterally-driven development which could compromise the normal integration of left and right ear input. We thus asked whether children hear a fused image (ie. 1 vs 2 sounds) from their bilateral implants and if this "binaural fusion" reduces listening effort. Binaural fusion was assessed by asking 25 deaf children with cochlear implants and 24 peers with normal hearing whether they heard one or two sounds when listening to bilaterally presented acoustic click-trains/electric pulses (250 Hz trains of 36 ms presented at 1 Hz). Reaction times and pupillary changes were recorded simultaneously to measure listening effort. Bilaterally implanted children heard one image of bilateral input less frequently than normal hearing peers, particularly when intensity levels on each side were balanced. Binaural fusion declined as brainstem asymmetries increased and age at implantation decreased. Children implanted later had access to acoustic input prior to implantation due to progressive deterioration of hearing. Increases in both pupil diameter and reaction time occurred as perception of binaural fusion decreased. Results indicate that, without binaural level cues, children have difficulty fusing input from their bilateral implants to perceive one sound which costs them increased listening effort. Brainstem asymmetries exacerbate this issue. By contrast, later implantation, reflecting longer access to bilateral acoustic hearing, may have supported development of auditory pathways underlying binaural fusion. Improved integration of bilateral cochlear implant signals for children is required to improve their binaural hearing.

  19. Multilateral and bilateral agreements

    International Nuclear Information System (INIS)

    Koponen, H.

    1993-01-01

    Finland has made both multilateral and bilateral agreements on the exchange of information related to radiation safety. The first arrangements for international agreements and exchange of information were made after the Chernobyl accident. In 1987, Finland joined the convention on early notification of a nuclear power accident coordinated by International Atomic Energy Agency. The convention is applied to accidents that cause of may cause emissions of radioactive substances that might affect the radiation safety of another country. Besides the convention on early notification, some other individual agreements have also been made. These include the International Nuclear Event Scale (INES) system and power companies own information exchange systems. Finland has conducted bilateral agreements with the Nordic countries and the Soviet Union on the notification of accidents and exchange of nuclear power plant information. Today, Russia answers for the Soviet Union's contractual obligations. (orig.)

  20. Fast-track surgery for bilateral total knee replacement

    DEFF Research Database (Denmark)

    Husted, H; Troelsen, A; Otte, K S

    2011-01-01

    Bilateral simultaneous total knee replacement (TKR) has been considered by some to be associated with increased morbidity and mortality. Our study analysed the outcome of 150 consecutive, but selected, bilateral simultaneous TKRs and compared them with that of 271 unilateral TKRs in a standardised...

  1. Simultaneous bilateral anterior cruciate ligament reconstruction: Cost comparison and functional results

    Directory of Open Access Journals (Sweden)

    Matjaž Sajovic

    2014-04-01

    Full Text Available Background: The ideal treatment for patients presenting with bilateral anterior cruciate ligament (ACL deficiency remains controversial. The purpose was to evaluate cost and mid-term functional results after one-stage bilateral ACL reconstruction using either hamstring or patella tendon autograft.Methods: We compared the mid-term outcome of 7 patients (14 knees who had one-stage bilateral ACL reconstruction with that of a matched group of patients who had unilateral reconstruction (21 patients.Results: The median duration of hospital stay was 4 nights (range 3 to 5 for the bilateral group and 2 nights (range, 1 to 4 for the control group. The duration of rehabilitation process in patients from the control group with unilateral ACL reconstruction was one week shorter (9 versus 8 weeks. In the bilateral group, the median Lysholm score was 96 (range 85–100 and in the control group, the median score was 93 (range 81–100. The median time to return to full-time work and to full sports was 9 weeks and 7 months for the simultaneous bilateral group and 8 weeks and 6 months for the unilateral group. Six patients (86 % in the bilateral group and 17 patients (81 % in the control group were still performing at their pre-injury level of activity. The Health Insurance Institute of Slovenia saves EUR 2,925 when we perform simultaneous bilateral ACL reconstruction instead of two stage ACL reconstruction.Conclusions: Mid-term clinical results suggested that simultaneous bilateral ACL reconstruction using either hamstring or patella tendon autograft is clinically effective. For patients presenting with symptomatic bilateral ACL deficient knees, one stage bilateral ACL reconstruction is reproducible, cost effective, and does not compromise functional results.

  2. Are unilateral and bilateral patellar tendinopathy distinguished by differences in anthropometry, body composition, or muscle strength in elite female basketball players?

    Science.gov (United States)

    Gaida, J E; Cook, J L; Bass, S L; Austen, S; Kiss, Z S

    2004-10-01

    Overuse injury to the patellar tendon (patellar tendinopathy) is a major reason for interrupted training and competition for elite athletes. In both sexes, the prevalence of unilateral and bilateral tendinopathy has been shown to differ. It has been proposed that bilateral pathology may have a different aetiology from unilateral pathology. Investigation of risk factors that may be unique to unilateral and bilateral patellar tendinopathy in female athletes may reveal insights into the aetiology of this condition. To examine whether anthropometry, body composition, or muscle strength distinguished elite female basketball players with unilateral or bilateral patellar tendinopathy. Body composition, anthropometry, and muscle strength were compared in elite female basketball players with unilateral (n = 8), bilateral (n = 7), or no (n = 24) patellar tendinopathy. Body composition was analysed using a dual energy x ray absorptiometer. Anthropometric measures were assessed using standard techniques. Knee extensor strength was measured at 180 degrees /s using an isokinetic dynamometer. z scores were calculated for the unilateral and bilateral groups (using the no tendinopathy group as controls). z scores were tested against zero. The tibia length to stature ratio was approximately 1.3 (1.3) SDs above zero in both the affected and non-affected legs in the unilateral group (ppatellar tendinopathy has identifiable risk factors whereas bilateral patellar tendinopathy may not. This suggests that the aetiology of these conditions may be different. However, interpretation must respect the limitation of small subject numbers.

  3. Laparoscopic Partial Adrenalectomy for Bilateral Cortisol-secreting Adenomas

    Directory of Open Access Journals (Sweden)

    Jeffrey P. Domino

    2007-04-01

    Full Text Available Bilateral cortisol-secreting adenomas are a rare cause of Cushing's syndrome. We report a case of a 35-year-old woman who presented with ACTH-independent Cushing's syndrome and bilateral adrenal adenomas. Adrenal venous sampling confirmed both adenomas to be hyper-secreting cortisol. She underwent bilateral laparoscopic adrenalectomy; total right and partial left adrenalectomies. At 2-year follow-up, she is maintained on low-dose fludrocortisone and hydrocortisone, and without recurrence of hypercorticolism. Laparoscopic partial adrenalectomy is a feasible option for this rare condition; however, long-term follow-up is needed to determine her total independence from steroid usage.

  4. Diagnostic accuracy and measurement sensitivity of digital models for orthodontic purposes: A systematic review.

    Science.gov (United States)

    Rossini, Gabriele; Parrini, Simone; Castroflorio, Tommaso; Deregibus, Andrea; Debernardi, Cesare L

    2016-02-01

    Our objective was to assess the accuracy, validity, and reliability of measurements obtained from virtual dental study models compared with those obtained from plaster models. PubMed, PubMed Central, National Library of Medicine Medline, Embase, Cochrane Central Register of Controlled Clinical trials, Web of Knowledge, Scopus, Google Scholar, and LILACs were searched from January 2000 to November 2014. A grading system described by the Swedish Council on Technology Assessment in Health Care and the Cochrane tool for risk of bias assessment were used to rate the methodologic quality of the articles. Thirty-five relevant articles were selected. The methodologic quality was high. No significant differences were observed for most of the studies in all the measured parameters, with the exception of the American Board of Orthodontics Objective Grading System. Digital models are as reliable as traditional plaster models, with high accuracy, reliability, and reproducibility. Landmark identification, rather than the measuring device or the software, appears to be the greatest limitation. Furthermore, with their advantages in terms of cost, time, and space required, digital models could be considered the new gold standard in current practice. Copyright © 2016 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  5. [Exploring a new method for superimposition of pre-treatment and post-treatment mandibular digital dental casts in adults].

    Science.gov (United States)

    Dai, F F; Liu, Y; Xu, T M; Chen, G

    2018-04-18

    To explore a cone beam computed tomography (CBCT)-independent method for mandibular digital dental cast superimposition to evaluate three-dimensional (3D) mandibular tooth movement after orthodontic treatment in adults, and to evaluate the accuracy of this method. Fifteen post-extraction orthodontic treatment adults from the Department of Orthodontics, Peking University School and Hospital of Stomatology were included. All the patients had four first premolars extracted, and were treated with straight wire appliance. The pre- and post-treatment plaster dental casts and craniofacial CBCT scans were obtained. The plaster dental casts were transferred to digital dental casts by 3D laser scanning, and lateral cephalograms were created from the craniofacial CBCT scans by orthogonal projection. The lateral cephalogram-based mandibular digital dental cast superimposition was achieved by sequential maxillary dental cast superimposition registered on the palatal stable region, occlusal transfer, and adjustment of mandibular rotation and translation obtained from lateral cephalogram superimposition. The accuracy of the lateral cephalogram-based mandibular digital dental cast superimposition method was evaluated with the CBCT-based mandibular digital dental cast superimposition method as the standard reference. After mandibular digital dental cast superimposition using both methods, 3D coordinate system was established, and 3D displacements of the lower bilateral first molars, canines and central incisors were measured. Differences between the two superimposition methods in tooth displacement measurements were assessed using the paired t-test with the level of statistical significance set at Pdigital dental cast superimposition methods in 3D displacements of the lower first molars, and sagittal and vertical displacements of the canines and central incisors; transverse displacements of the canines and central incisors differed by (0.3±0.5) mm with statistical significance

  6. Severe Bilateral Breast Mucinous Carcinoma with Bilateral Lungs and Cutaneous Metastasis: A Case Report and Literature Review

    Directory of Open Access Journals (Sweden)

    Rong Pu

    2018-01-01

    Full Text Available The case of a female who had severe, rare, terminal breast mucinous carcinoma (BMC and failed to receive surgery and chemotherapy was reported. The patient was diagnosed with pure BMC (ER++, PR++, CerbB-2−, and Ki-67 10% accompanied with bilateral lungs, bilateral chest walls with skin ulcer (D = 14 cm, lymph nodes of bilateral armpits, and right supraclavicular metastases. ECOG (Eastern Cooperative Oncology Group and NRS (Numeric Rating Scale pain scores were 4 and 6, respectively. Because the patient refused traditional chemotherapy and radiotherapy on religious grounds, an herbal medicine containing Panax ginseng, Agrimonia pilosa, and white flower Patrinia herb was administered; extensive nursing for tumor debridement was also provided. Quality of Life (QOL improved and pain reduced. Tumor-bearing survival time was prolonged. The present case dictates that herbal extract medicines and supportive treatment can be helpful for uncommon severe BMC as an appropriate alternative treatment.

  7. Bilateral cerebellopontine arachnoid cyst: A rare entity.

    Science.gov (United States)

    Sharma, Anand; Sharma, Achal; Mittal, Radhey S; Gandhi, Ashok

    2015-01-01

    Bilateral cerebellopontine angle (CPA) arachnoid cysts (ACs) are very rare: only one case is reported in literature. Pathogenesis of those cysts is unknown; they are thought to be congenital. The presenting symptoms of CPA AC are frequently nonspecific or otological. The management of ACs of the CPA is controversial. We are reporting two cases of bilateral CPA AC with their pathophysiology and review of literature.

  8. Bilateral teleoperation for force sensorless 1-dof robots

    NARCIS (Netherlands)

    Lichiardopol, S.; Wouw, van de N.; Nijmeijer, H.; Filipe, J.; Cetto, J.A.; Ferrier, J.-L.

    2010-01-01

    It is well known that for bilateral teleoperation, force feedback information is needed. In this paper, we propose a control approach for bilateral teleoperation with uncertainties in the model of the slave robot and which does not use force sensors for haptic feedback. The controller design is

  9. Patient-reported utilities in bilateral visual impairment from amblyopia and age-related macular degeneration.

    Science.gov (United States)

    van de Graaf, Elizabeth S; Despriet, Dominiek D G; Klaver, Caroline C W; Simonsz, Huibert J

    2016-05-17

    Utility of visual impairment caused by amblyopia is important for the cost-effectiveness of screening for amblyopia (lazy eye, prevalence 3-3.5 %). We previously measured decrease of utility in 35-year-old persons with unilateral persistent amblyopia. The current observational case-control study aimed to measure loss of utility in patients with amblyopia with recent decrease of vision in their better eye. As these patients are rare, the sample was supplemented by patients with bilateral age-related macular degeneration with similar decrease of vision. From our out-patient department, two groups of patients with recent deterioration to bilateral visual acuity less than Snellen 0.5 (bilateral visual impairment, BVI) were recruited, with either persistent amblyopia and age-related macular degeneration (AMB + AMD), or with bilateral age-related macular degeneration (BAMD). To measure utility, the time trade-off method and the standard gamble method were applied through interviews. Correlations were sought between utility values and visual acuity, age and Visual Function Questionnaire-25 scores. Seventeen AMB + AMD patients (mean age 72.9 years), and 63 BAMD patients (mean age 79.6 years) were included in the study. Among AMB + AMD, 80 % were willing to trade lifetime in exchange for cure. The overall mean time trade-off utility was 0.925. Among BAMD, 75 % were willing to trade, utility was 0.917. Among AMB + AMD, 38 % accepted risk of death in exchange for cure, overall mean standard gamble utility was 0.999. Among BAMD, 49 % accepted risk of death, utility was 0.998. Utility was not related to visual acuity but it was to age (p = 0.02). Elderly patients with BVI, caused by persistent amblyopia and age-related macular degeneration (AMD) or by bilateral AMD, had an approximately 8 % loss of TTO utility. Notably, the 8 % loss in elderly with BVI differs little from the 3.7 % loss we found previously in 35-year-old persons with unilateral

  10. Simulation and Measurement of the Transmission Distortions of the Digital Television DVB-T/H Part 2: Hierarchical Modulation Performance

    Directory of Open Access Journals (Sweden)

    R. Stukavec

    2010-09-01

    Full Text Available The paper deals with the second part of results of the Czech Science Foundation research project that was aimed into the simulation and measurement of the transmission distortions of the digital terrestrial television according to DVB-T/H standards. In this part the hierarchical modulation performance characteristics and its simulation and laboratory measurements are presented. The paper deals with the hierarchical oriented COFDM modulator for the digital terrestrial television transmission and DVB-T/H standards and possible utilization of this technique in real broadcasting scenarios – fixed, portable and mobile digital TV, all in one TV channel. Impact of the hierarchical modulation on Modulation Error Rate from I/Q constellations and Bit Error Rates before and after Viterbi decoding in DVB-T/H signal decoding are evaluated and discussed.

  11. Bilateral nanophthalmos and pigmentary retinal dystrophy--an unusual syndrome.

    Science.gov (United States)

    Proença, Helena; Castanheira-Dinis, A; Monteiro-Grillo, M

    2006-09-01

    To report the clinical picture of the rare association of nanophthalmos and pigmentary retinal dystrophy and its cataract surgery outcome. We report a case of a 60-year-old female who presented with bilateral slowly progressive visual loss. The patient presented with bilateral light perception visual acuity, exotropia, brunescent cataract hindering fundus examination and hypodontia. Ultrasonography revealed bilateral nanophthalmos. A visual-evoked potential was also performed preoperatively. Cataract surgery with +40D IOL implantation was uneventful. Postoperative fundus examination revealed pigmentary retinal dystrophy, confirmed by electrophysiologic tests. Glycosaminoglycan urinary excretion was normal. Congenital bilateral nanophthalmos may rarely be associated with pigmentary retinal dystrophy. We suggest thorough preoperative evaluation in nanophthalmic eyes for the exclusion of significant features concerning visual prognosis.

  12. Specific Changes in Young Soccer Player's Fitness After Traditional Bilateral vs. Unilateral Combined Strength and Plyometric Training

    Directory of Open Access Journals (Sweden)

    Rodrigo Ramirez-Campillo

    2018-03-01

    Full Text Available The aim of this study was to compare changes in young soccer player's fitness after traditional bilateral vs. unilateral combined plyometric and strength training. Male athletes were randomly divided in two groups; both received the same training, including strength training for knee extensors and flexors, in addition to horizontal plyometric training drills. The only difference between groups was the mode of drills technique: unilateral (UG; n = 9; age, 17.3 ± 1.1 years vs. bilateral (TG; n = 9; age, 17.6 ± 0.5 years. One repetition maximum bilateral strength of knee muscle extensors (1RM_KE and flexors (1RM_KF, change of direction ability (COD, horizontal and vertical jump ability with one (unilateral and two (bilateral legs, and limb symmetry index were measured before and after an 8-week in-season intervention period. Some regular soccer drills were replaced by combination of plyometric and strength training drills. Magnitude-based inference statistics were used for between-group and within-group comparisons. Beneficial effects (p < 0.05 in 1RM_KE, COD, and several test of jumping performance were found in both groups in comparison to pre-test values. The limb symmetry index was not affected in either group. The beneficial changes in 1RM_KE (8.1%; p = 0.074 and 1RM_KF (6.7%; p = 0.004, COD (3.1%; p = 0.149, and bilateral jump performance (from 2.7% [p = 0.535] to 10.5% [p = 0.002] were possible to most likely beneficial in the TG than in the UG. However, unilateral jump performance measures achieved likely to most likely beneficial changes in the UG compared to the TG (from 4.5% [p = 0.090] to 8.6% [p = 0.018]. The improvements in jumping ability were specific to the type of jump performed, with greater improvements in unilateral jump performance in the UG and bilateral jump performance in the TG. Therefore, bilateral strength and plyometric training should be complemented with unilateral drills, in order to maximize adaptations.

  13. Synchronous bilateral male breast cancer: a case report.

    Science.gov (United States)

    Sun, Woo-Young; Lee, Ki-Hyeong; Lee, Ho-Chang; Ryu, Dong-Hee; Park, Jin-Woo; Yun, Hyo-Young; Song, Young-Jin

    2012-06-01

    Synchronous bilateral breast cancer is extremely rare in men and has not, up to date, been reported in Korea. A 54-year-old man presented with a palpable mass in the right breast. The right nipple was retracted and bilateral axillary accessory breasts and nipples were present. On physical examination, a 2 cm-sized mass was palpated directly under the right nipple, and, with squeezing, bloody discharge developed in a single duct of the left nipple. There was no palpable mass in the left breast, and axillary lymph nodes were not palpable. Physical examination of external genitalia revealed a unilateral undescended testis on the left side. Synchronous bilateral breast cancer was diagnosed using mammography, ultrasonography, and core-needle biopsy. Histopathological examination revealed invasive ductal carcinoma in the right breast and ductal carcinoma in situ in the left breast. Bilateral total mastectomy, sentinel lymph node biopsy, and excision of accessory breasts in the axilla were performed.

  14. Bilateral patellar tuberculosis masquerading as infected infrapatellar bursitis.

    Science.gov (United States)

    Sreenivasan, Ravi; Haq, Rehan Ul

    2017-04-01

    A 30-year-old woman presented to our outpatient department with complaints of pain and swelling in bilateral infrapatellar regions and a discharging sinus in the right knee over the duration of one year. Radiographs showed lytic regions in bilateral patellae. Samples sent from material curetted from sinus yielded no organism but histopathology reported granulomatous inflammation. Following a fresh magnetic resonance imaging (MRI) scan that revealed the infrapatellar pad of fat communicating with the patellar lesions, an exploration and evacuation was done. Material sent revealed epithelioid cell granulomas with caseous necrosis consistent with tuberculosis (TB). The patient was put on first line anti-tubercular treatment (ATT) and has responded favourably with healing of sinus and patellar lesions. Bilateral infrapatellar bursitis is not rare. However patellar TB as a cause for OMIT is not a common diagnosis. A bilateral patellar involvement has not been reported in literature to the best of our knowledge.

  15. Digital PIV Measurements in the Diffuser of a High Speed Centrifugal Compressor

    Science.gov (United States)

    Wernet, Mark P.

    1998-01-01

    Particle Imaging Velocimetry (PIV) is a powerful measurement technique which can be used as an alternative or complementary approach to Laser Doppler Velocimetry (LDV) in a wide range of research applications. PIV data are measured simultaneously at multiple points in space, which enables the investigation of the non-stationary spatial structures typically encountered in turbomachinery. Obtaining ample optical access, sufficiently high seed particle concentrations and accurate synchronization of image acquisition relative to impeller position are the most formidable tasks in the successful implementation of PIV in turbomachinery. Preliminary results from the successful application of the standard 2-D digital PIV technique in the diffuser of a high speed centrifugal compressor are presented. Instantaneous flow. measurements were also obtained during compressor surge.

  16. Bilateral Parotid Sialadenosis Associated with Long-Standing Bulimia: A Case Report and Literature Review.

    Science.gov (United States)

    Garcia Garcia, Blas; Dean Ferrer, Alicia; Diaz Jimenez, Nelida; Alamillos Granados, Francisco Jesus

    2018-06-01

    Bulimia is a common cause of sialadenosis. This paper presents a case of bilateral parotid sialadenosis associated with long-standing bulimia, and reviews the relevant literature and current treatment options. A 32-year-old woman had severe bilateral parotid sialomegaly for the last 6 years, which had occurred secondary to bulimia nervosa, which she had since 14 years. Treatment with pilocarpine was unsuccessful, so she underwent bilateral conservative parotidectomy. This procedure not only improved the aesthetic appearance of the patient but also improved her social and work life and overall quality of life. Sialomegaly secondary to bulimia results in a major alteration of the aesthetics of a patient's face. Conservative measures are not enough in many cases, and parotidectomy may be the only viable option, as it can also significantly improve adherence to psychiatric treatment for bulimia, in addition to correcting the facial aesthetics.

  17. Bilateral Supernumerary Kidney: A Very Rare Presentation

    International Nuclear Information System (INIS)

    Keskin, Suat; Batur, Abdussamet; Keskin, Zeynep; Koc, Abdulkadir; Firat Ozcan, Irfan

    2014-01-01

    To our knowledge, bilateral supernumerary kidney is a very rare renal abnormality and there are five cases presented in the literature. It is difficult to diagnose supernumerary kidney and clinicians have not detected most cases preoperatively. Laboratory and imaging studies were acquired and carefully examined. The normal laboratory tests were found. Emergency ultrasonography was performed and they revealed no signs of parenchymal abnormality in both kidneys. Serial imaging study including enhanced computed tomography (CT) was performed. An imaging study identified bilateral supernumerary kidney with expanded collecting systems. On each side, significant rotation anomaly was found. In addition, there were two different renal arteries originating from the aorta. This report presents radiological determinations of supernumerary kidney bilaterally in a young man. We think that CT commonly appears to be enough for the diagnosis of supernumerary kidneys

  18. Measurement of Local Deformations in Steel Monostrands Using Digital Image Correlation

    DEFF Research Database (Denmark)

    Winkler, Jan; Fischer, Gregor; Georgakis, Christos T.

    2014-01-01

    The local deformation mechanisms in steel monostrands have a significant influence on their fatigue life and failure mode. However, the observation and quantification of deformations in monostrands experiencing axial and transverse deformations is challenging because of their complex geometry......, difficulties with the placement of strain gauges in the vicinity of the anchorage, and, most importantly, the relatively small magnitude of deformation occurring in the monostrand. This paper focuses on the measurement of localized deformations in high-strength steel monostrands using the digital image...... correlation (DIC) technique. The presented technique enables the measurement of individual wire strains along the length of the monostrand and also provides quantitative information on the relative movement between individual wires, leading to a more in-depth understanding of the underlying fatigue mechanisms...

  19. Clinical performance evaluation of total protein measurement by digital refractometry and characterization of non-protein solute interferences

    Directory of Open Access Journals (Sweden)

    Joshua J.H. Hunsaker

    2016-12-01

    Full Text Available Objectives: Refractometric methods to measure total protein (TP in serum and plasma specimens have been replaced by automated biuret methods in virtually all routine clinical testing. A subset of laboratories, however, still report using refractometry to measure TP in conjunction with serum protein electrophoresis. The objective of this study was therefore to conduct a modern performance evaluation of a digital refractometer for TP measurement. Design and methods: Performance evaluation of a MISCO Palm Abbe™ digital refractometer was conducted through device familiarization, carryover, precision, accuracy, linearity, analytical sensitivity, analytical specificity, and reference interval verification. Comparison assays included a manual refractometer and an automated biuret assay. Results: Carryover risk was eliminated using a demineralized distilled water (ddH2O wash step. Precision studies demonstrated overall imprecision of 2.2% CV (low TP pool and 0.5% CV (high TP pool. Accuracy studies demonstrated correlation to both manual refractometry and the biuret method. An overall positive bias (+5.0% was observed versus the biuret method. On average, outlier specimens had an increased triglyceride concentration. Linearity was verified using mixed dilutions of: a low and high concentration patient pools, or b albumin-spiked ddH2O and high concentration patient pool. Decreased recovery was observed using ddH2O dilutions at low TP concentrations. Significant interference was detected at high concentrations of glucose (>267 mg/dL and triglycerides (>580 mg/dL. Current laboratory reference intervals for TP were verified. Conclusions: Performance characteristics of this digital refractometer were validated in a clinical laboratory setting. Biuret method remains the preferred assay for TP measurement in routine clinical analyses. Keywords: Refractometry, Digital refractometry, Total protein, Biuret, Serum protein electrophoresis, Monoclonal

  20. Bilateral cerebral hemispheric infarction associated with sildenafil citrate (Viagra) use.

    Science.gov (United States)

    Kim, K-K; Kim, D G; Ku, Y H; Lee, Y J; Kim, W-C; Kim, O J; Kim, H S

    2008-03-01

    Sildenafil citrate (Viagra) is one of the frequently prescribed drugs for men with erectile dysfunction. We describe a 52-year-old man with bilateral middle cerebral artery (MCA) territory infarction after sildenafil use. He ingested 100 mg of sildenafil and about 1 h later, he complained of chest discomfort, palpitation and dizziness followed by mental obtundation, global aphasia and left hemiparesis. Brain magnetic resonance imaging documented acute bilateral hemispheric infarction, and cerebral angiography showed occluded bilateral MCA. Despite significant bilateral MCA stenosis and cerebral infarction, systemic hypotension persisted for a day. We presume that cerebral infarction was caused by cardioembolism with sildenafil use.

  1. Homogeneous bilateral block shifts

    Indian Academy of Sciences (India)

    Douglas class were classified in [3]; they are unilateral block shifts of arbitrary block size (i.e. dim H(n) can be anything). However, no examples of irreducible homogeneous bilateral block shifts of block size larger than 1 were known until now.

  2. Measuring the global information society - explaining digital inequality by economic level and education standard

    Science.gov (United States)

    Ünver, H.

    2017-02-01

    A main focus of this research paper is to investigate on the explanation of the ‘digital inequality’ or ‘digital divide’ by economic level and education standard of about 150 countries worldwide. Inequality regarding GDP per capita, literacy and the so-called UN Education Index seem to be important factors affecting ICT usage, in particular Internet penetration, mobile phone usage and also mobile Internet services. Empirical methods and (multivariate) regression analysis with linear and non-linear functions are useful methods to measure some crucial factors of a country or culture towards becoming information and knowledge based society. Overall, the study concludes that the convergence regarding ICT usage proceeds worldwide faster than the convergence in terms of economic wealth and education in general. The results based on a large data analysis show that the digital divide is declining over more than a decade between 2000 and 2013, since more people worldwide use mobile phones and the Internet. But a high digital inequality explained to a significant extent by the functional relation between technology penetration rates, education level and average income still exists. Furthermore it supports the actions of countries at UN/G20/OECD level for providing ICT access to all people for a more balanced world in context of sustainable development by postulating that policymakers need to promote comprehensive education worldwide by means of using ICT.

  3. US findings of bilateral primary breast cancer: Retrospective study

    International Nuclear Information System (INIS)

    Lou Li; Cong Xinli; Yu Guofang; Li Jichang; Ma Yuxiang

    2007-01-01

    Background: For women with breast cancer, the contralateral breast is at high risk. The bilateral cancers may be synchronous or metachronous. If the bilateral breast cancers have similar ultrasonography (US) appearances, the US findings of the first breast cancer (index cancer) might lead to early detection of the contralateral cancer. The purpose of this study was to identify the US characteristics of bilateral breast cancer and to determine whether bilateral breast cancers have similar US appearances and whether the US findings for one breast cancer might be predictive of the contralateral breast cancer. Methods: We retrospectively reviewed the US manifestations of 58 patients with surgically proven bilateral primary breast cancer and compared the contralateral cancer with the index cancer by evaluation the margin, shape, inside echoes, posterior attenuation, calcification and color flow signals of 58 lesion pairs to investigate whether the bilateral breast cancers have similar US appearances. Results: Bilateral primary breast cancers were more located in upper outer quadrant, frequently spiculation, taller than wide shape, with irregular margin, heterogeneous internal echo and acoustic shadowing, containing microcalcification and abundant color flow signals. The most common US appearances were taller than wide shape (75.0%, 87/116), irregular margins (79.3%, 92/116) and heterogeneous internal echo (86.2%, 100/116). Of the total 58 lesion pairs, 18 (31.0%) pairs had similar US characteristics, whereas 40 (69.0%) pairs had different US characteristics. Conclusions: US signs of the index cancer do not indicate the most likely appearance of the second cancer in the contralateral breast. Evaluation of the contralateral cancer should be performed without regard for the US findings for the index cancer

  4. A digital silicon photomultiplier with multiple time-to-digital converters

    Energy Technology Data Exchange (ETDEWEB)

    Garutti, Erika [University Hamburg (Germany); Silenzi, Alessandro [DESY, Hamburg (Germany); Xu, Chen [DESY, Hamburg (Germany); University Hamburg (Germany)

    2013-07-01

    A silicon photomultiplier (SiPM) with pixel level signal digitization and column-wise connected time-to-digital converters (TDCs) has been developed for an endoscopic Positron Emission Tomography (PET) detector. A digital SiPM has pixels consist of a single photon avalanche diode (SPAD) and circuit elements to optimize overall dark counts and temporal response. Compared with conventional analog SiPM, digital SiPM's direct signal route from SPAD to TDC improves single photon time resolution. In addition, using multiple TDCs can perform the statistical estimation of the time-of-arrival in multiple photon detection case such as readout of scintillation crystals. Characterization measurements of the prototype digital SiPM and a Monte-Carlo simulation to predict the timing performance of the PET detector are shown.

  5. The unpredictable outcomes of bilateral simultaneous fractures of ...

    African Journals Online (AJOL)

    Bilateral simultaneous fractures of Neck of Femur (NOF) are rare. They result amongst others from trauma, metabolic disease, electro-convulsion and simple falls. We report two cases of 40-year-old and 74-year-old females who presented with bilateral simultaneous fractures of NOF post simple falls. Both patients had ...

  6. Stabilization of Bilateral Progressive Rheumatoid Corneal Melt with Infliximab

    Directory of Open Access Journals (Sweden)

    Sheelah F. Antao

    2012-01-01

    Results. A patient with rheumatoid arthritis presented with bilateral PUK following a 2-month history of ocular discomfort and redness. His systemic prednisolone (PDN and methotrexate (MTX were increased and, despite an initial favorable response, bilateral recurrent corneal perforations ensued. Both eyes underwent cyanoacrylate glue repair, amniotic membrane transplantation (AMT, and penetrating keratoplasty (PKP. Recurrence of the disease and bilateral perforations of the second PKP in both eyes prompted administration of intravenous infliximab immediately after the fourth PKP. The disease activity rapidly settled in both eyes, and at eighteen-month followup, after 12 infliximab infusions, the PUK remains quiescent with no further graft thinning or perforation. Conclusion. Infliximab can be used to arrest the progression of severe bilateral rheumatoid PUK in cases that are refractory to conventional treatment.

  7. Cryptogenic organising pneumonia presenting with bilateral hilar and mediastinal lymphadenopathy.

    Science.gov (United States)

    Kahraman, Hasan; Tokur, Mahmut; Sayar, Hamide; Inci, Mehmet Fatih

    2013-06-10

    Cryptogenic organising pneumonia is not considered in the differential diagnosis of bilateral hilar and mediastinal lymphadenopathy. We submitted a patient presenting with bilateral hilar and mediastinal lymphadenopathy. We suspected diagnosis of sarcoidosis, but the patient was diagnosed as cryptogenic organising pneumonia with the histological result. This is the second case report of cryptogenic organising pneumonia presenting with bilateral hilar and mediastinal lymphadenopathy.

  8. Binaural Fusion and Listening Effort in Children Who Use Bilateral Cochlear Implants: A Psychoacoustic and Pupillometric Study

    Science.gov (United States)

    Steel, Morrison M.; Papsin, Blake C.; Gordon, Karen A.

    2015-01-01

    Bilateral cochlear implants aim to provide hearing to both ears for children who are deaf and promote binaural/spatial hearing. Benefits are limited by mismatched devices and unilaterally-driven development which could compromise the normal integration of left and right ear input. We thus asked whether children hear a fused image (ie. 1 vs 2 sounds) from their bilateral implants and if this “binaural fusion” reduces listening effort. Binaural fusion was assessed by asking 25 deaf children with cochlear implants and 24 peers with normal hearing whether they heard one or two sounds when listening to bilaterally presented acoustic click-trains/electric pulses (250 Hz trains of 36 ms presented at 1 Hz). Reaction times and pupillary changes were recorded simultaneously to measure listening effort. Bilaterally implanted children heard one image of bilateral input less frequently than normal hearing peers, particularly when intensity levels on each side were balanced. Binaural fusion declined as brainstem asymmetries increased and age at implantation decreased. Children implanted later had access to acoustic input prior to implantation due to progressive deterioration of hearing. Increases in both pupil diameter and reaction time occurred as perception of binaural fusion decreased. Results indicate that, without binaural level cues, children have difficulty fusing input from their bilateral implants to perceive one sound which costs them increased listening effort. Brainstem asymmetries exacerbate this issue. By contrast, later implantation, reflecting longer access to bilateral acoustic hearing, may have supported development of auditory pathways underlying binaural fusion. Improved integration of bilateral cochlear implant signals for children is required to improve their binaural hearing. PMID:25668423

  9. Binaural fusion and listening effort in children who use bilateral cochlear implants: a psychoacoustic and pupillometric study.

    Directory of Open Access Journals (Sweden)

    Morrison M Steel

    Full Text Available Bilateral cochlear implants aim to provide hearing to both ears for children who are deaf and promote binaural/spatial hearing. Benefits are limited by mismatched devices and unilaterally-driven development which could compromise the normal integration of left and right ear input. We thus asked whether children hear a fused image (ie. 1 vs 2 sounds from their bilateral implants and if this "binaural fusion" reduces listening effort. Binaural fusion was assessed by asking 25 deaf children with cochlear implants and 24 peers with normal hearing whether they heard one or two sounds when listening to bilaterally presented acoustic click-trains/electric pulses (250 Hz trains of 36 ms presented at 1 Hz. Reaction times and pupillary changes were recorded simultaneously to measure listening effort. Bilaterally implanted children heard one image of bilateral input less frequently than normal hearing peers, particularly when intensity levels on each side were balanced. Binaural fusion declined as brainstem asymmetries increased and age at implantation decreased. Children implanted later had access to acoustic input prior to implantation due to progressive deterioration of hearing. Increases in both pupil diameter and reaction time occurred as perception of binaural fusion decreased. Results indicate that, without binaural level cues, children have difficulty fusing input from their bilateral implants to perceive one sound which costs them increased listening effort. Brainstem asymmetries exacerbate this issue. By contrast, later implantation, reflecting longer access to bilateral acoustic hearing, may have supported development of auditory pathways underlying binaural fusion. Improved integration of bilateral cochlear implant signals for children is required to improve their binaural hearing.

  10. Accurate kinematic measurement at interfaces between dissimilar materials using conforming finite-element-based digital image correlation

    KAUST Repository

    Tao, Ran; Moussawi, Ali; Lubineau, Gilles; Pan, Bing

    2016-01-01

    Digital image correlation (DIC) is now an extensively applied full-field measurement technique with subpixel accuracy. A systematic drawback of this technique, however, is the smoothening of the kinematic field (e.g., displacement and strains

  11. Luxatio erecta bilateral: um relato de caso Bilateral luxatio erecta, a case report

    Directory of Open Access Journals (Sweden)

    César Augusto Xavier Acosta

    2012-02-01

    Full Text Available O deslocamento inferior do ombro (luxatio erecta é uma lesão rara, acometendo aproximadamente 0,5% dos deslocamentos dessa articulação. A grande maioria desses casos ocorre unilateralmente. Em setembro de 2004, um homem de 43 anos chegou ao pronto-socorro do Hospital Universitário de Santa Maria (HUSM com queixa de dor bilateral no ombro e incapacidade de abaixar os braços, em consequência de uma queda com os braços abduzidos, enquanto desempenhava sua atividade laboral. Após o exame físico e radiológico constatou- se que o indivíduo apresentava uma luxação inferior bilateral dos ombros. O paciente foi então encaminhado ao bloco cirúrgico onde foi realizada redução incruenta das luxações sob anestesia através da técnica de tração e contra-tração. No dia seguinte recebeu alta com imobilização tipo Velpeau mantendo os ombros totalmente aduzidos e rotados internamente, com orientação de manter a imobilização por três semanas. Foi orientado também a realizar fisioterapia.Inferior shoulder dislocation (luxactio erecta is a rare lesion affecting approximately 0.5% of dislocations of this joint. The vast majority of these cases occur unilaterally. In September 2004, a 43 year old man was brought to the emergency room of the University Hospital of Santa Maria (HUSM complaining of bilateral shoulder pain and inability to lower the arms, as a result of a fall with the arms abducted, while carrying out work activities. After physical examination and radiological exams, it was found that the patient had a bilateral inferior shoulder dislocation. He was referred to the surgical ward and after intravenous sedation, both shoulders were reduced by closed reduction using the traction-countertraction maneuver. The patient was discharged the day after the reduction. Both arms were immobilized with a velpeau sling in total adduction and intrarotation, with instructions to maintain immobilization for three weeks. The patient was

  12. Bilateral Herpes Simplex Uveitis: Review of the Literature and Own Reports‏.

    Science.gov (United States)

    de-la-Torre, Alejandra; Valdes-Camacho, Juanita; Foster, C Stephen

    2017-08-01

    Herpes simplex-associated uveitis is usually considered a unilateral eye disease, and rarely included in the differential diagnosis whenever there is bilateral involvement. We report three cases of bilateral herpetic anterior uveitis. We evaluated three patients who presented with clinical manifestations of bilateral uveitis suggestive of viral origin. We found intraocular hypertension, cells in the anterior chamber, paralytic mydriasis, iris atrophy with transillumination defects, and variable anterior vitreous cellularity. According to the clinical findings, supported with herpes-specific antibody titers and aqueous humor PCR results in two of them, they were diagnosed with bilateral anterior herpetic uveitis. Our patients were initially misdiagnosed as having non-infectious uveitis and were treated with immunomodulatory medications, which could have favored the extension of infection bilaterally. Although uncommon, bilateral herpetic uveitis should always be considered in the differential diagnoses, when patients present with hypertensive uveitis in both eyes.

  13. Synchronous, bilateral tonsillar carcinomas

    DEFF Research Database (Denmark)

    Nami Saber, Camelia; Grønhøj, Christian; Jensen, David Hebbelstrup

    2017-01-01

    INTRODUCTION: The incidence of oropharyngeal squamous cell carcinoma (OPSCC) is increasing, but data on the incidence of synchronous, bilateral tonsillar squamous cell carcinomas (BiTSCCs) is sparse. In this study, we report the incidence and tumour characteristics of BiTSCCs in a population-base...

  14. Bilateral acoustic neuromas.

    Science.gov (United States)

    Anand, V T; Byrnes, D P; Walby, A P; Kerr, A G

    1993-10-01

    This article reviews 12 patients with bilateral acoustic neuromas. The sex incidence was equal and the mean age at diagnosis was 26.2 years. The family history was positive in nine of the patients. Five patients have had incomplete surgical removal of acoustic neuromas on both sides. Two of them are completely deaf and the other three have severe sensorineural hearing loss in one ear and no hearing in the other ear. In five patients the tumour on one side has been operated on and the other side is being observed with at least short-term preservation of good hearing. The remaining two patients died of intra-cranial complications, one of them post-operatively. Four patients developed facial palsy immediately following surgery and one developed facial weakness 6 months after surgery. Guidelines are discussed for the care of these patients including the timing of surgery and alternative treatment options (observation, radio-surgery and chemotherapy). This is essentially a group of young individuals who have had multiple operations for bilateral acoustic tumours and associated manifestations and for whom the disease and the sequelae of treatment can be tragic.

  15. Simultaneous bilateral contracture of the infraspinatus muscle.

    Science.gov (United States)

    Franch, J; Bertran, J; Remolins, G; Fontecha, P; Díaz-Bertrana, M C; Durall, I

    2009-01-01

    A case of bilateral fibrotic contracture of the infraspinatus muscles in a five-year-old Belgian Shepherd dog is described. The dog was presented with progressive forelimb lameness with postural and gait abnormalities three months after an episode of overexertion. When walking, the lower part of both forelimbs swung in a lateral arc causing a circumduction movement and in the standing position, the dog showed elbow adduction with external rotation of the distal part of both front limbs. Orthopaedic examination revealed bilateral atrophy of both infraspinatus and supraspinatus muscles and restriction in the range of motion of both shoulders, especially when attempting abduction and flexion. No specific findings were observed in the shoulder or elbow radiographs but hyperechogenic areas were evident in the ultrasonographic examination of both infraspinatus muscles. A diagnosis of fibrotic contracture of both infraspinatus muscles was established and bilateral tenectomy of the insertion tendons of the infraspinatus muscles was performed. Complete recovery of the animal was achieved after the surgery, which was confirmed in a long-term follow-up (10 months). In conclusion, physical examination and ultrasonography allowed a proper diagnosis of the condition, and tenectomy of the infraspinatus muscles resulted in a complete recovery of the patient even with bilateral involvement.

  16. High Performance, Three-Dimensional Bilateral Filtering

    International Nuclear Information System (INIS)

    Bethel, E. Wes

    2008-01-01

    Image smoothing is a fundamental operation in computer vision and image processing. This work has two main thrusts: (1) implementation of a bilateral filter suitable for use in smoothing, or denoising, 3D volumetric data; (2) implementation of the 3D bilateral filter in three different parallelization models, along with parallel performance studies on two modern HPC architectures. Our bilateral filter formulation is based upon the work of Tomasi [11], but extended to 3D for use on volumetric data. Our three parallel implementations use POSIX threads, the Message Passing Interface (MPI), and Unified Parallel C (UPC), a Partitioned Global Address Space (PGAS) language. Our parallel performance studies, which were conducted on a Cray XT4 supercomputer and aquad-socket, quad-core Opteron workstation, show our algorithm to have near-perfect scalability up to 120 processors. Parallel algorithms, such as the one we present here, will have an increasingly important role for use in production visual analysis systems as the underlying computational platforms transition from single- to multi-core architectures in the future.

  17. High Performance, Three-Dimensional Bilateral Filtering

    Energy Technology Data Exchange (ETDEWEB)

    Bethel, E. Wes

    2008-06-05

    Image smoothing is a fundamental operation in computer vision and image processing. This work has two main thrusts: (1) implementation of a bilateral filter suitable for use in smoothing, or denoising, 3D volumetric data; (2) implementation of the 3D bilateral filter in three different parallelization models, along with parallel performance studies on two modern HPC architectures. Our bilateral filter formulation is based upon the work of Tomasi [11], but extended to 3D for use on volumetric data. Our three parallel implementations use POSIX threads, the Message Passing Interface (MPI), and Unified Parallel C (UPC), a Partitioned Global Address Space (PGAS) language. Our parallel performance studies, which were conducted on a Cray XT4 supercomputer and aquad-socket, quad-core Opteron workstation, show our algorithm to have near-perfect scalability up to 120 processors. Parallel algorithms, such as the one we present here, will have an increasingly important role for use in production visual analysis systems as the underlying computational platforms transition from single- to multi-core architectures in the future.

  18. Bilateral Supernumerary Kidney: A Very Rare Presentation

    Science.gov (United States)

    Keskin, Suat; Batur, Abdussamet; Keskin, Zeynep; Koc, Abdulkadir; Firat Ozcan, Irfan

    2014-01-01

    To our knowledge, bilateral supernumerary kidney is a very rare renal abnormality and there are five cases presented in the literature. It is difficult to diagnose supernumerary kidney and clinicians have not detected most cases preoperatively. Laboratory and imaging studies were acquired and carefully examined. The normal laboratory tests were found. Emergency ultrasonography was performed and they revealed no signs of parenchymal abnormality in both kidneys. Serial imaging study including enhanced computed tomography (CT) was performed. An imaging study identified bilateral supernumerary kidney with expanded collecting systems. On each side, significant rotation anomaly was found. In addition, there were two different renal arteries originating from the aorta. This report presents radiological determinations of supernumerary kidney bilaterally in a young man. We think that CT commonly appears to be enough for the diagnosis of supernumerary kidneys. PMID:25780543

  19. Bilateral ureteropelvic junction obstruction presenting with hypertension and cerebral vascular accident.

    Science.gov (United States)

    Tourchi, Ali; Kajbafzadeh, Abdolmohammad; Nejat, Farideh; Golmohammadi, Abolfazl; Alizadeh, Farshid; Mahboobi, Amir Hassan

    2010-11-01

    Cerebrovascular accident and renal hypertension secondary to ureteropelvic junction obstruction (UPJO) are extremely rare. A 6-year-old girl presented with intracranial hemorrhage because of hypertension secondary to the bilateral UPJO. This was successfully treated with craniotomy and subsequent percutaneous nephrostomy placement and bilateral pyeloplasty. Brain computerized tomography revealed right-sided intracranial hemorrhage, and renal ultrasonography confirmed bilateral severe hydronephrosis. Craniotomy with evacuation of intracerebral hematoma and bilateral nephrostomy under ultrasound guidance were performed. One week later, she underwent bilateral pyeloplasty in 2 stages. The patient has been well with normalized renal function and is completely cured of her hypertension in long-term follow-up. Copyright © 2010 Elsevier Inc. All rights reserved.

  20. A Cost-Effective Transparency-Based Digital Imaging for Efficient and Accurate Wound Area Measurement

    Science.gov (United States)

    Li, Pei-Nan; Li, Hong; Wu, Mo-Li; Wang, Shou-Yu; Kong, Qing-You; Zhang, Zhen; Sun, Yuan; Liu, Jia; Lv, De-Cheng

    2012-01-01

    Wound measurement is an objective and direct way to trace the course of wound healing and to evaluate therapeutic efficacy. Nevertheless, the accuracy and efficiency of the current measurement methods need to be improved. Taking the advantages of reliability of transparency tracing and the accuracy of computer-aided digital imaging, a transparency-based digital imaging approach is established, by which data from 340 wound tracing were collected from 6 experimental groups (8 rats/group) at 8 experimental time points (Day 1, 3, 5, 7, 10, 12, 14 and 16) and orderly archived onto a transparency model sheet. This sheet was scanned and its image was saved in JPG form. Since a set of standard area units from 1 mm2 to 1 cm2 was integrated into the sheet, the tracing areas in JPG image were measured directly, using the “Magnetic lasso tool” in Adobe Photoshop program. The pixel values/PVs of individual outlined regions were obtained and recorded in an average speed of 27 second/region. All PV data were saved in an excel form and their corresponding areas were calculated simultaneously by the formula of Y (PV of the outlined region)/X (PV of standard area unit) × Z (area of standard unit). It took a researcher less than 3 hours to finish area calculation of 340 regions. In contrast, over 3 hours were expended by three skillful researchers to accomplish the above work with traditional transparency-based method. Moreover, unlike the results obtained traditionally, little variation was found among the data calculated by different persons and the standard area units in different sizes and shapes. Given its accurate, reproductive and efficient properties, this transparency-based digital imaging approach would be of significant values in basic wound healing research and clinical practice. PMID:22666449

  1. Bilateral Tubal Gestation Associated with Schistosomiasis in an African Woman

    Directory of Open Access Journals (Sweden)

    K. H. Odubamowo

    2014-01-01

    Full Text Available Background. The incidence of tubal ectopic gestation caused by schistosomiasis induced tubal pathology is undocumented in this environment, which may be due to rarity of this pathology. Bilateral tubal gestation is common in patients that have undergone in vitro fertilization. We report a hitherto undocumented case of spontaneous bilateral ectopic gestation following tubal schistosomiasis. Case Report. Mrs. OB was a 32-year-old G4P3+0 (3 alive woman who complained of abdominal pain and bleeding per vaginam of 4 and 2 days’ duration respectively following 8 weeks of amenorrhea. A clinical impression of ruptured ectopic gestation was confirmed by ultrasound scanning. She had bilateral salpingectomy with histology of specimens showing bilateral ectopic gestation with Schistosoma haematobium induced salpingitis (findings of Schistosoma haematobium ova noted on slide. Conclusion. Schistosoma induced salpingitis is a rare but possible cause of bilateral tubal gestation.

  2. The Relationship between Binaural Benefit and Difference in Unilateral Speech Recognition Performance for Bilateral Cochlear Implant Users

    Science.gov (United States)

    Yoon, Yang-soo; Li, Yongxin; Kang, Hou-Yong; Fu, Qian-Jie

    2011-01-01

    Objective The full benefit of bilateral cochlear implants may depend on the unilateral performance with each device, the speech materials, processing ability of the user, and/or the listening environment. In this study, bilateral and unilateral speech performances were evaluated in terms of recognition of phonemes and sentences presented in quiet or in noise. Design Speech recognition was measured for unilateral left, unilateral right, and bilateral listening conditions; speech and noise were presented at 0° azimuth. The “binaural benefit” was defined as the difference between bilateral performance and unilateral performance with the better ear. Study Sample 9 adults with bilateral cochlear implants participated. Results On average, results showed a greater binaural benefit in noise than in quiet for all speech tests. More importantly, the binaural benefit was greater when unilateral performance was similar across ears. As the difference in unilateral performance between ears increased, the binaural advantage decreased; this functional relationship was observed across the different speech materials and noise levels even though there was substantial intra- and inter-subject variability. Conclusions The results indicate that subjects who show symmetry in speech recognition performance between implanted ears in general show a large binaural benefit. PMID:21696329

  3. Comparing Binaural Pre-processing Strategies II: Speech Intelligibility of Bilateral Cochlear Implant Users.

    Science.gov (United States)

    Baumgärtel, Regina M; Hu, Hongmei; Krawczyk-Becker, Martin; Marquardt, Daniel; Herzke, Tobias; Coleman, Graham; Adiloğlu, Kamil; Bomke, Katrin; Plotz, Karsten; Gerkmann, Timo; Doclo, Simon; Kollmeier, Birger; Hohmann, Volker; Dietz, Mathias

    2015-12-30

    Several binaural audio signal enhancement algorithms were evaluated with respect to their potential to improve speech intelligibility in noise for users of bilateral cochlear implants (CIs). 50% speech reception thresholds (SRT50) were assessed using an adaptive procedure in three distinct, realistic noise scenarios. All scenarios were highly nonstationary, complex, and included a significant amount of reverberation. Other aspects, such as the perfectly frontal target position, were idealized laboratory settings, allowing the algorithms to perform better than in corresponding real-world conditions. Eight bilaterally implanted CI users, wearing devices from three manufacturers, participated in the study. In all noise conditions, a substantial improvement in SRT50 compared to the unprocessed signal was observed for most of the algorithms tested, with the largest improvements generally provided by binaural minimum variance distortionless response (MVDR) beamforming algorithms. The largest overall improvement in speech intelligibility was achieved by an adaptive binaural MVDR in a spatially separated, single competing talker noise scenario. A no-pre-processing condition and adaptive differential microphones without a binaural link served as the two baseline conditions. SRT50 improvements provided by the binaural MVDR beamformers surpassed the performance of the adaptive differential microphones in most cases. Speech intelligibility improvements predicted by instrumental measures were shown to account for some but not all aspects of the perceptually obtained SRT50 improvements measured in bilaterally implanted CI users. © The Author(s) 2015.

  4. Bilateral responses of upper limb muscles to transcranial magnetic stimulation in human subjects.

    Science.gov (United States)

    Bawa, P; Hamm, J D; Dhillon, P; Gross, P A

    2004-10-01

    Anatomical and behavioural work on primates has shown bilateral innervation of axial and proximal limb muscles, and contralateral control of distal limb muscles. The following study examined if a clear boundary exists between the distal and proximal upper limb muscles that are controlled contralaterally or bilaterally. The right motor cortical area representing the upper limb was stimulated, while surface EMG was recorded bilaterally from various upper limb muscles during rest and phasic voluntary contractions. Peak-to-peak amplitude of motor evoked potential (MEP) was measured for each muscle on both sides. The ratio R = (ipsilateral MEP: contralateral MEP) was calculated for seven pairs of muscles. For each of the seven pairs, R was less than 1.0, implying that for each muscle and subject, the contralateral control is stronger. The boundary where R changed from almost zero to a clearly measurable magnitude depended on the subject. Ipsilateral MEPs from trapezius and pectoralis could be recorded with a small background contraction from almost all subjects; on the other hand, in deltoid and biceps brachii, ipsilateral MEPs were observed only with bimanual phasic contractions. The forearm and hand muscles, in general, did not show any ipsilateral MEPs. Major differences between subjects lay in the presence or the absence of ipsilateral MEPs in biceps brachii and deltoid, without defining a sharp boundary between proximal and distal muscles.

  5. Parálisis diafragmática bilateral. Presentación de un caso Bilateral diaphragmatic paralysis

    Directory of Open Access Journals (Sweden)

    Jorge Carnot Pereira

    2012-04-01

    Full Text Available La parálisis diafragmática bilateral es una entidad muy infrecuente en la clínica, debido a diferentes entidades con capacidad de lesionar el nervio frénico. El compromiso respiratorio que produce requiere cuidado especializado. Este es el primer caso reportado en nuestra literatura a consecuencia de hernias cervicales múltiples. Se presenta un caso de un paciente de 43 años, con antecedentes de salud, exatleta de alto rendimiento, que ingresó en nuestro servicio, con disnea de 5 meses de evolución, que aumentó progresivamente en intensidad hasta mantenerlo en ortopnea constante, fue estudiado exhaustivamente hasta llegar a diagnostico definido y derivarlo al servicio de Neurocirugía para su solución definitiva. La importancia del tema que se presenta es que se describe una presentación rara de parálisis diafragmática bilateral, a consecuencia de hernias discales cervicales múltiples.Bilateral diaphragmatic paralysis is a rare condition in clinical practice due to different entities that can damage phrenic nerve. The resulting respiratory compromise requires medical special care. This is the first case reported in our medical literature caused by multiple cervical hernias. A 43 year-old patient having health history, high performance ex-athlete, admitted in the service with 5-month evolution of dyspnea which progressively increased in intensity up to maintain him in permanent orthopnea, thorough studies were conducted to the definite diagnosis and he was transferred to Neurosurgery Service to a definite solution. A rare presentation of a bilateral diaphragmatic paralysis resulting from multiple cervical hernias gives importance to the topic.

  6. Digit ratio (2D:4D) and circulating testosterone, oestradiol, and progesterone levels across the menstrual cycle.

    Science.gov (United States)

    Richards, Gareth; Klimek, Magdalena; Jasienska, Grazyna; Marcinkowska, Urszula M

    2018-02-01

    Digit ratio (2D:4D) is used by researchers as an indicator of prenatal sex hormone exposure. Two previous studies have examined associations between 2D:4D and circulating sex steroid concentrations across the menstrual cycle in adult females. One reported that digit ratio correlated positively with oestradiol levels, whereas the other found no such effect; neither observed significant associations with progesterone. To examine associations between 2D:4D, as well as asymmetry (i.e. right minus left 2D:4D), and circulating sex steroids across the menstrual cycle. Correlational. 32 naturally cycling adult females from rural southern Poland. Salivary oestradiol, progesterone, testosterone, and testosterone to oestradiol ratio (T:O) measured during the follicular, peri-ovulatory, and luteal phases. Average levels across the cycle were also examined. Asymmetry in digit ratio correlated positively with oestradiol at each phase, as well as with average levels across the cycle. Each association, other than that relating to average levels, remained statistically significant after a range of covariates had been controlled for. No other significant correlations were observed between digit ratio variables and circulating hormone levels. Our results might suggest that low exposure to androgens and/or high exposure to oestrogens during gestation is a predictor of high oestradiol levels in naturally cycling females of reproductive age. However, considering that it was asymmetry in digit ratio, and not either right or left 2D:4D, that was a significant predictor, it is also possible that these effects reflect more general associations between bilateral asymmetry and circulating oestradiol levels. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Delayed diagnosis of homocystinuria presenting as bilateral congenital lens subluxation

    OpenAIRE

    Jelić-Vuković Marija; Matić Suzana; Barać Josip; Novinščak Tomislav; Belovari Mirna; Barić Hrvoje

    2017-01-01

    Introduction. Homocystinuria is an autosomal recessively inherited defect leading to hyperhomocysteinemia and associated with ocular manifestations, mainly myopia and ectopia lentis. Case outline. A 26-year-old male with secondary glaucoma due to bilateral lens subluxation was admitted to the Department of vitreoretinal surgery. Horizontal nystagmus, bilateral lens subluxation, and bilateral amblyopia were first discovered at the age of three years. Preoperative laboratory workup revealed ele...

  8. Hardware Implementation of a Bilateral Subtraction Filter

    Science.gov (United States)

    Huertas, Andres; Watson, Robert; Villalpando, Carlos; Goldberg, Steven

    2009-01-01

    A bilateral subtraction filter has been implemented as a hardware module in the form of a field-programmable gate array (FPGA). In general, a bilateral subtraction filter is a key subsystem of a high-quality stereoscopic machine vision system that utilizes images that are large and/or dense. Bilateral subtraction filters have been implemented in software on general-purpose computers, but the processing speeds attainable in this way even on computers containing the fastest processors are insufficient for real-time applications. The present FPGA bilateral subtraction filter is intended to accelerate processing to real-time speed and to be a prototype of a link in a stereoscopic-machine- vision processing chain, now under development, that would process large and/or dense images in real time and would be implemented in an FPGA. In terms that are necessarily oversimplified for the sake of brevity, a bilateral subtraction filter is a smoothing, edge-preserving filter for suppressing low-frequency noise. The filter operation amounts to replacing the value for each pixel with a weighted average of the values of that pixel and the neighboring pixels in a predefined neighborhood or window (e.g., a 9 9 window). The filter weights depend partly on pixel values and partly on the window size. The present FPGA implementation of a bilateral subtraction filter utilizes a 9 9 window. This implementation was designed to take advantage of the ability to do many of the component computations in parallel pipelines to enable processing of image data at the rate at which they are generated. The filter can be considered to be divided into the following parts (see figure): a) An image pixel pipeline with a 9 9- pixel window generator, b) An array of processing elements; c) An adder tree; d) A smoothing-and-delaying unit; and e) A subtraction unit. After each 9 9 window is created, the affected pixel data are fed to the processing elements. Each processing element is fed the pixel value for

  9. Bilateral Rhegmatogenous Retinal Detachment during External Beam Radiotherapy

    Directory of Open Access Journals (Sweden)

    Takako Hidaka

    2016-06-01

    Full Text Available Herein, we report a case of nontraumatic bilateral rhegmatogenous retinal detachment (RRD during external beam radiotherapy for nonocular tumor, presented as an observational case study in conjunction with a review of the relevant literature. A 65-year-old male was referred to our hospital due to bilateral RRD. He underwent a biopsy for a tumor of the left frontal lobe 4 months prior to presentation, and the tumor had been diagnosed as primary central nerve system B-cell type lymphoma. He received chemotherapy and external beam radiotherapy for 1 month. There were no traumatic episodes. Bilateral retinal detachment occurred during a series of radiotherapies. Simultaneous nontraumatic bilateral retinal detachment is rare. The effects of radiotherapy on ocular functionality, particularly in cases involving retinal adhesion and vitreous contraction, may include RRD. Thus, it is necessary to closely monitor the eyes of patients undergoing radiotherapy, particularly those undergoing surgery for retinal detachment and those with a history of photocoagulation for retinal tears, a relevant family history, or risk factors known to be associated with RRD.

  10. Pielonefritis enfisematosa aguda bilateral: Un desafío terapéutico Acute bilateral emphysematous pyelonephritis: A therapeutic challenge

    Directory of Open Access Journals (Sweden)

    Marcelo J. Melero

    2007-06-01

    Full Text Available La pielonefritis enfisematosa es una forma poco común de infección renal, caracterizada por la presencia de bacterias coliformes productoras de gas que afecta preferentemente a los pacientes diabéticos. Comunicamos el caso de una mujer diabética de 57 años de edad que ingresó en el hospital por un shock séptico, signos de pielonefritis enfisematosa aguda bilateral y cetoacidosis diabética. En los cultivos de las muestras de orina y sangre desarrolló Escherichia coli. La paciente fue tratada exitosamente con antibióticos de amplio espectro por un tiempo prolongado, control diabético y medidas de sostén solamente. No fue necesario el drenaje con catéteres o la nefrectomía para superar esta situación potencialmente letal.Emphysematous pyelonephritis is a rare form of kidney infection characterized by the presence of gas-forming coliform bacteria which affects more frequently diabetic subjects. We report the case of a 57-years-old diabetic woman, who was admitted in septic shock, signs of acute bilateral emphysematous pyelonephritis, and diabetic ketoacidosis. Both blood and urine cultures yielded Escherichia coli. The patient was successfully treated using long-term broad-spectrum antibiotics, diabetic control and supportive measures alone. Catheter drainage and nephrectomy were not necessary to overcome this life threatening situation.

  11. Bilateral Moyamoya Disease in a 2-Year-Old Pakistani Male Treated with Bilateral Encephaloduroarteriosynangiosis: A Positive Outcome

    Directory of Open Access Journals (Sweden)

    Shahvaiz Magsi

    2016-01-01

    Full Text Available Background. We present a rare case of bilateral moyamoya disease presenting as multiple strokes and neurological deficits, treated with the neurosurgical procedure, encephaloduroarteriosynangiosis (EDAS, in a 2-year-old male Pakistani minor. A positive outcome was achieved and the patient recovered fully. Case Summary. Our patient presented with a history of seizures and multiple episodes of hemiparesis (on and off weakness at the age of 2 years. He had a delayed speech development and could not speak more than a few words. He had a slight slurring of speech too. He was diagnosed with bilateral moyamoya disease on Computed Tomography Angiography (CTA. Bilateral EDAS was done in the same year, after which his symptoms improved and patient had moderate functional recovery. Conclusion. A rare disease, moyamoya has been left unexplored in Pakistan; physicians and surgeons when dealing with cases in the pediatric population presenting with symptoms of stroke, signs of generalized weakness, and seizures should consider moyamoya disease as a possibility. Furthermore, this case demonstrates the effectiveness of EDAS procedure for the treatment of moyamoya disease.

  12. Bilateral pulmonary infiltrates in association with disseminated actinomycosis.

    Science.gov (United States)

    Dontfraid, F; Ramphal, R

    1994-07-01

    The most common infectious cause of bilateral upper-lobe pulmonary disease is tuberculosis. However, we recently encountered a patient with bilateral apical infiltrates and multiple soft-tissue abscesses caused by Actinomyces odontolyticus. Other findings included fever, weight loss, and leukocytosis, and the patient's only known source of immunosuppression was a long history of alcoholism. There was no history of diabetes, steroid use, or other chronic underlying disease. The diagnosis was made by culture of drainage fluid from one abscess. Therapy with intravenous penicillin G led to rapid clinical improvement and reduction in the infiltrates. To our knowledge, the presentation of pulmonary infection, with bilateral apical infiltrates due to A. odontolyticus has not been previously reported in the medical literature.

  13. Accuracy of Digital vs Conventional Implant Impression Approach: A Three-Dimensional Comparative In Vitro Analysis.

    Science.gov (United States)

    Basaki, Kinga; Alkumru, Hasan; De Souza, Grace; Finer, Yoav

    To assess the three-dimensional (3D) accuracy and clinical acceptability of implant definitive casts fabricated using a digital impression approach and to compare the results with those of a conventional impression method in a partially edentulous condition. A mandibular reference model was fabricated with implants in the first premolar and molar positions to simulate a patient with bilateral posterior edentulism. Ten implant-level impressions per method were made using either an intraoral scanner with scanning abutments for the digital approach or an open-tray technique and polyvinylsiloxane material for the conventional approach. 3D analysis and comparison of implant location on resultant definitive casts were performed using laser scanner and quality control software. The inter-implant distances and interimplant angulations for each implant pair were measured for the reference model and for each definitive cast (n = 20 per group); these measurements were compared to calculate the magnitude of error in 3D for each definitive cast. The influence of implant angulation on definitive cast accuracy was evaluated for both digital and conventional approaches. Statistical analysis was performed using t test (α = .05) for implant position and angulation. Clinical qualitative assessment of accuracy was done via the assessment of the passivity of a master verification stent for each implant pair, and significance was analyzed using chi-square test (α = .05). A 3D error of implant positioning was observed for the two impression techniques vs the reference model, with mean ± standard deviation (SD) error of 116 ± 94 μm and 56 ± 29 μm for the digital and conventional approaches, respectively (P = .01). In contrast, the inter-implant angulation errors were not significantly different between the two techniques (P = .83). Implant angulation did not have a significant influence on definitive cast accuracy within either technique (P = .64). The verification stent

  14. Comparing bilateral to unilateral electroconvulsive therapy in a randomized study with EEG monitoring.

    Science.gov (United States)

    Horne, R L; Pettinati, H M; Sugerman, A A; Varga, E

    1985-11-01

    In a double-blind study, 48 DSM-III depressed patients were randomly assigned to either the bilateral or nondominant unilateral electroconvulsive therapy (ECT) group. Seizure length was monitored by electroencephalography (EEG). When seizures were less than 25 s, ECT was immediately readministered. When length of seizure and pretreatment depression scores were controlled between the two groups, there were no differences in treatment effectiveness, as measured by the Hamilton Rating Scale for Depression and the Beck Depression Inventory, or in the number of treatments required. This was true after five ECT treatments as well as after completing all ECT treatments. Thus, when ECT is monitored via EEG to assure the presence of an adequate seizure, bilateral and nondominant unilateral placement yield equivalent responses. If ECT had not been readministered immediately following a missed seizure, unilateral patients would have had significantly more missed seizures. Significant difficulties in both short- and long-term memory were found 24 hours after the fifth ECT in bilateral but not in nondominant unilateral patients. No apparent memory loss could be documented in nondominant unilateral ECT.

  15. Digital Marketing Communication

    OpenAIRE

    Margherita Corniani

    2006-01-01

    Digital marketing communication is directed to profiled targets, which are active in the communication process. Every communication flow can ask for an information answer from the market. This opportunity grants immediate feed-backs and feed-forwards, so that digital communication can be easily and cheaply measured; digital communication flows are diffused at costs that are getting lower and lower, but it asks specialized and deep competences to communication managers. The ease in the flowing...

  16. Phacoemulsification of bilateral cataracts in two pet rabbits | Gomes ...

    African Journals Online (AJOL)

    Two 3 year-old, healthy, client-owned Lop rabbits presented with bilateral cataracts. After performing a physical examination, bloodwork, ocular ultrasonography and electroretinography, both animals were deemed good surgical candidates for phacoemulsification. Bilateral cataract surgery was performed and both rabbits ...

  17. Bilateral spontaneous pneumothorax with pulmonary metastases of synovial sarcoma

    International Nuclear Information System (INIS)

    Matushita, J.P.K.; Azevedo, C.M. de

    1989-01-01

    The association of bilateral spontaneous pneumothorax with pulmonary tumor is uncommon and with pulmonary metastases is rare. The clinical and radiological features of bilateral spontaneous pneumothorax from a synovial sarcoma in a 14 years old boy are described. (author) [pt

  18. Bilateral nasolabial cysts - case report and review of literature

    International Nuclear Information System (INIS)

    Patil, Aruna R; Singh, Abhinav Pratap; Nandikoor, Shrivalli; Meganathan, Prabhu

    2016-01-01

    Nasolabial cyst is a non-odontogenic, extraosseous, soft tissue cyst, commonly unilateral, located in the nasolabial fold. Bilateral nasolabial cysts are of rare occurrence. This case report describes the multimodality imaging appearance of bilateral nasolabial cysts with a review of literature

  19. UNITED STATES/GERMAN TECHNICAL BILATERAL AGREEMENT: PAST, PRESENT & FUTURE

    Science.gov (United States)

    The U.S. Environmental Protection Agency (EPA) and the German Federal Ministry of Education and Research (BMBF) entered into a Bilateral Agreement in 1990 to study each country's efforts in developing and demonstrating remedial technologies. The bilateral agreement is being impl...

  20. Digital signal processing for velocity measurements in dynamical material's behaviour studies

    International Nuclear Information System (INIS)

    Devlaminck, Julien; Luc, Jerome; Chanal, Pierre-Yves

    2014-01-01

    In this work, we describe different configurations of optical fiber interferometers (types Michelson and Mach-Zehnder) used to measure velocities during dynamical material's behaviour studies. We detail the algorithms of processing developed and optimized to improve the performance of these interferometers especially in terms of time and frequency resolutions. Three methods of analysis of interferometric signals were studied. For Michelson interferometers, the time-frequency analysis of signals by Short-Time Fourier Transform (STFT) is compared to a time-frequency analysis by Continuous Wavelet Transform (CWT). The results have shown that the CWT was more suitable than the STFT for signals with low signal-to-noise, and low velocity and high acceleration areas. For Mach- Zehnder interferometers, the measurement is carried out by analyzing the phase shift between three interferometric signals (Triature processing). These three methods of digital signal processing were evaluated, their measurement uncertainties estimated, and their restrictions or operational limitations specified from experimental results performed on a pulsed power machine. (authors)

  1. Effects of walking speed on asymmetry and bilateral coordination of gait

    Science.gov (United States)

    Plotnik, Meir; Bartsch, Ronny P.; Zeev, Aviva; Giladi, Nir; Hausdorff, Jeffery M.

    2013-01-01

    The mechanisms regulating the bilateral coordination of gait in humans are largely unknown. Our objective was to study how bilateral coordination changes as a result of gait speed modifications during over ground walking. 15 young adults wore force sensitive insoles that measured vertical forces used to determine the timing of the gait cycle events under three walking conditions (i.e., usual-walking, fast and slow). Ground reaction force impact (GRFI) associated with heel-strikes was also quantified, representing the potential contribution of sensory feedback to the regulation of gait. Gait asymmetry (GA) was quantified based on the differences between right and left swing times and the bilateral coordination of gait was assessed using the phase coordination index (PCI), a metric that quantifies the consistency and accuracy of the anti-phase stepping pattern. GA was preserved in the three different gait speeds. PCI was higher (reduced coordination) in the slow gait condition, compared to usual-walking (3.51% vs. 2.47%, respectively, p=0.002), but was not significantly affected in the fast condition. GRFI values were lower in the slow walking as compared to usual-walking and higher in the fast walking condition (pgait related changes in PCI were not associated with the slowed gait related changes in GRFI. The present findings suggest that left-right anti-phase stepping is similar in normal and fast walking, but altered during slowed walking. This behavior might reflect a relative increase in attention resources required to regulate a slow gait speed, consistent with the possibility that cortical function and supraspinal input influences the bilateral coordination of gait. PMID:23680424

  2. Force-velocity properties' contribution to bilateral deficit during ballistic push-off.

    Science.gov (United States)

    Samozino, Pierre; Rejc, Enrico; di Prampero, Pietro Enrico; Belli, Alain; Morin, Jean-Benoît

    2014-01-01

    The objective of this study is to quantify the contribution of the force-velocity (F-v) properties to bilateral force deficit (BLD) in ballistic lower limb push-off and to relate it to individual F-v mechanical properties of the lower limbs. The F-v relation was individually assessed from mechanical measurements for 14 subjects during maximal ballistic lower limb push-offs; its contribution to BLD was then investigated using a theoretical macroscopic approach, considering both the mechanical constraints of movement dynamics and the maximal external capabilities of the lower limb neuromuscular system. During ballistic lower limb push-off, the maximum force each lower limb can produce was lower during bilateral than unilateral actions, thus leading to a BLD of 36.7% ± 5.7%. The decrease in force due to the F-v mechanical properties amounted to 19.9% ± 3.6% of the force developed during BL push-offs, which represents a nonneural contribution to BLD of 43.5% ± 9.1%. This contribution to BLD that cannot be attributed to changes in neural features was negatively correlated to the maximum unloaded extension velocity of the lower limb (r = -0.977, P push-off, BLD is due to both neural alterations and F-v mechanical properties, the latter being associated with the change in movement velocity between bilateral and unilateral actions. The level of the contribution of the F-v properties depends on the individual F-v mechanical profile of the entire lower limb neuromuscular system: the more the F-v profile is oriented toward velocity capabilities, the lower the loss of force from unilateral to bilateral push-offs due to changes in movement velocity.

  3. Pros and cons of immediately sequential bilateral cataract surgery (ISBCS).

    Science.gov (United States)

    Grzybowski, Andrzej; Wasinska-Borowiec, Weronika; Claoué, Charles

    2016-01-01

    Immediately sequential bilateral cataract surgery (ISBCS) is currently a "hot topic" in ophthalmology. There are well-documented advantages in terms of quicker visual rehabilitation and reduced costs. The risk of bilateral simultaneous endophthalmitis and bilateral blindness is now recognized to be minuscule with the advent of intracameral antibiotics and modern management of endophthalmitis. Refractive surprises are rare for normal eyes and with the use of optical biometry. Where a general anesthetic is indicated for cataract surgery, the risk of death from a second anesthetic is much higher than the risk of blindness. A widely recognized protocol from the International Society of Bilateral Cataract Surgeons needs to be adhered to if surgeons wish to start practicing ISBCS.

  4. Bilateral cochlear implants in infants: a new approach--Nucleus Hybrid S12 project.

    Science.gov (United States)

    Gantz, Bruce J; Dunn, Camille C; Walker, Elizabeth A; Kenworthy, Maura; Van Voorst, Tanya; Tomblin, Bruce; Turner, Chris

    2010-10-01

    The purpose of this feasibility study was to evaluate whether the use of a shorter-length cochlear implant (10 mm) on one ear and a standard electrode (24 mm) on the contralateral ear is a viable bilateral option for children with profound bilateral sensorineural hearing loss. A secondary purpose of this study was to determine whether the ear with the shorter-length electrode performs similarly to the standard-length electrode. Our goal was to provide an option of electrical stimulation that theoretically might preserve the structures of the scala media and organ of Corti. The study is being conducted as a repeated-measure, single-subject experiment. University of Iowa-Department of Otolaryngology. Eight pediatric patients with profound bilateral sensorineural hearing loss between the ages of 12 and 24 months. Nucleus Hybrid S12 10-mm electrode and a Nucleus Freedom implant in the contralateral ear. The Infant-Toddler Meaningful Auditory Integration Scale (IT-MAIS) parent questionnaire, Early Speech Perception, Glendonald Auditory Screening Procedure word test, and Children's Vowel tests will be used to evaluate speech perception and the Minnesota Child Development Inventory and Preschool Language Scales 3 test will be used to evaluate language growth. Preliminary results for 8 children have been collected before and after the operation using the IT-MAIS. All 3 children showed incremental improvements in their IT-MAIS scores overtime. Early Speech Perception, Glendonald Auditory Screening Procedure word test, and Children's Vowel word perception results indicated no difference between the individual ears for the 2 children tested. Performance compared with age-matched children implanted with standard bilateral cochlear implants showed similar results to the children implanted with Nucleus Hybrid S12 10-mm electrode and a Nucleus Freedom implant in contralateral ears. The use of a shorter-length cochlear implant on one ear and a standard-length electrode on the

  5. Measures of digit span and verbal rehearsal speed in deaf children after more than 10 years of cochlear implantation.

    Science.gov (United States)

    Pisoni, David B; Kronenberger, William G; Roman, Adrienne S; Geers, Ann E

    2011-02-01

    Conventional assessments of outcomes in deaf children with cochlear implants (CIs) have focused primarily on endpoint or product measures of speech and language. Little attention has been devoted to understanding the basic underlying core neurocognitive factors involved in the development and processing of speech and language. In this study, we examined the development of factors related to the quality of phonological information in immediate verbal memory, including immediate memory capacity and verbal rehearsal speed, in a sample of deaf children after >10 yrs of CI use and assessed the correlations between these two process measures and a set of speech and language outcomes. Of an initial sample of 180 prelingually deaf children with CIs assessed at ages 8 to 9 yrs after 3 to 7 yrs of CI use, 112 returned for testing again in adolescence after 10 more years of CI experience. In addition to completing a battery of conventional speech and language outcome measures, subjects were administered the Wechsler Intelligence Scale for Children-III Digit Span subtest to measure immediate verbal memory capacity. Sentence durations obtained from the McGarr speech intelligibility test were used as a measure of verbal rehearsal speed. Relative to norms for normal-hearing children, Digit Span scores were well below average for children with CIs at both elementary and high school ages. Improvement was observed over the 8-yr period in the mean longest digit span forward score but not in the mean longest digit span backward score. Longest digit span forward scores at ages 8 to 9 yrs were significantly correlated with all speech and language outcomes in adolescence, but backward digit spans correlated significantly only with measures of higher-order language functioning over that time period. While verbal rehearsal speed increased for almost all subjects between elementary grades and high school, it was still slower than the rehearsal speed obtained from a control group of normal

  6. Measurements of granular flow dynamics with high speed digital images

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jingeol [Univ. of Florida, Gainesville, FL (United States)

    1994-01-01

    The flow of granular materials is common to many industrial processes. This dissertation suggests and validates image processing algorithms applied to high speed digital images to measure the dynamics (velocity, temperature and volume fraction) of dry granular solids flowing down an inclined chute under the action of gravity. Glass and acrylic particles have been used as granular solids in the experiment. One technique utilizes block matching for spatially averaged velocity measurements of the glass particles. This technique is compared with the velocity measurement using an optic probe which is a conventional granular flow velocity measurement device. The other technique for measuring the velocities of individual acrylic particles is developed with correspondence using a Hopfield network. This technique first locates the positions of particles with pattern recognition techniques, followed by a clustering technique, which produces point patterns. Also, several techniques are compared for particle recognition: synthetic discriminant function (SDF), minimum average correlation energy (MACE) filter, modified minimum average correlation energy (MMACE) filter and variance normalized correlation. The author proposes an MMACE filter which improves generalization of the MACE filter by adjusting the amount of averaged spectrum of training images in the spectrum whitening stages of the MACE filter. Variance normalized correlation is applied to measure the velocity and temperature of flowing glass particles down the inclined chute. The measurements are taken for the steady and wavy flow and qualitatively compared with a theoretical model of granular flow.

  7. Bilateral papillary renal cell carcinoma

    International Nuclear Information System (INIS)

    Gossios, K.; Vazakas, P.; Argyropoulou, M.; Stefanaki, S.; Stavropoulos, N.E.

    2001-01-01

    Papillary renal cell carcinoma is a subgroup of malignant renal epithelial neoplasms. We report the clinical and imaging findings of a case with multifocal and bilateral renal cell carcinoma which are nonspecific. (orig.)

  8. Sample-interpolation timing: an optimized technique for the digital measurement of time of flight for γ rays and neutrons at relatively low sampling rates

    International Nuclear Information System (INIS)

    Aspinall, M D; Joyce, M J; Mackin, R O; Jarrah, Z; Boston, A J; Nolan, P J; Peyton, A J; Hawkes, N P

    2009-01-01

    A unique, digital time pick-off method, known as sample-interpolation timing (SIT) is described. This method demonstrates the possibility of improved timing resolution for the digital measurement of time of flight compared with digital replica-analogue time pick-off methods for signals sampled at relatively low rates. Three analogue timing methods have been replicated in the digital domain (leading-edge, crossover and constant-fraction timing) for pulse data sampled at 8 GSa s −1 . Events arising from the 7 Li(p, n) 7 Be reaction have been detected with an EJ-301 organic liquid scintillator and recorded with a fast digital sampling oscilloscope. Sample-interpolation timing was developed solely for the digital domain and thus performs more efficiently on digital signals compared with analogue time pick-off methods replicated digitally, especially for fast signals that are sampled at rates that current affordable and portable devices can achieve. Sample interpolation can be applied to any analogue timing method replicated digitally and thus also has the potential to exploit the generic capabilities of analogue techniques with the benefits of operating in the digital domain. A threshold in sampling rate with respect to the signal pulse width is observed beyond which further improvements in timing resolution are not attained. This advance is relevant to many applications in which time-of-flight measurement is essential

  9. A new time-digital convert circuit based on digital delay line

    International Nuclear Information System (INIS)

    Liu Haifeng; Guo Ying; Zhang Zhi

    2004-01-01

    An introduction of a new method of time-digital convert circuit based on digital delay line is given. High precision and good reliability can be realized when it is combined with traditional counting convert method in the measurement of large scale pulse width and low frequency self-excitation oscillator. (authors)

  10. Validity and reliability of a low-cost digital dynamometer for measuring isometric strength of lower limb.

    Science.gov (United States)

    Romero-Franco, Natalia; Jiménez-Reyes, Pedro; Montaño-Munuera, Juan A

    2017-11-01

    Lower limb isometric strength is a key parameter to monitor the training process or recognise muscle weakness and injury risk. However, valid and reliable methods to evaluate it often require high-cost tools. The aim of this study was to analyse the concurrent validity and reliability of a low-cost digital dynamometer for measuring isometric strength in lower limb. Eleven physically active and healthy participants performed maximal isometric strength for: flexion and extension of ankle, flexion and extension of knee, flexion, extension, adduction, abduction, internal and external rotation of hip. Data obtained by the digital dynamometer were compared with the isokinetic dynamometer to examine its concurrent validity. Data obtained by the digital dynamometer from 2 different evaluators and 2 different sessions were compared to examine its inter-rater and intra-rater reliability. Intra-class correlation (ICC) for validity was excellent in every movement (ICC > 0.9). Intra and inter-tester reliability was excellent for all the movements assessed (ICC > 0.75). The low-cost digital dynamometer demonstrated strong concurrent validity and excellent intra and inter-tester reliability for assessing isometric strength in the main lower limb movements.

  11. Bilateral cheiloschisis in bovine - A case report

    Directory of Open Access Journals (Sweden)

    Saulo Andrade Caldas

    2014-01-01

    Full Text Available ABSTRACT. Caldas S.A., Nogueira V.A., Lima A.E.S., Aragão A.P., d’Avila M.S., Santos A.M., Miranda I.C., Costa S.Z.R. & Peixoto T.C. [Bilateral cheiloschisis in bovine - A case report.] Queilosquise bilateral em bovino - Relato de caso. Revista Brasileira de Medicina Veterinária, 36(1:55-59, 2014. Departamento de Medicina e Cirurgia Veterinária, Instituto de Veterinária, Universidade Federal Rural do Rio de Janeiro, BR 465 Km 7, Seropédica RJ 23890-000, Brasil. E-mail: saulocaldas@hotmail.com A case of bilateral queilosquise in a cattle two years old was reported. Clinically, there was cachexia, difficulty in grasping food and water intake. The clinical examination revealed that the nasal orifices were discontinuous with the upper lip, which allowed communication between the nostrils and mouth in its rostral portion, crowding of incisors (tweezers, as well as exposure of medium and the 2nd corner and of the tongue. In this case, the bilateral queilosquise was the result of flaws in fusion of the maxillary process and the medial nasal process and its surroundings, probably due to mineral deficiencies of pregnant cow. This pathogenesis was suggested by excluding other possible causes, the knowledge of the existence of mineral deficiencies in the region where the event occurred and bad nutritional status of pregnant female.

  12. Measurement of definite integral of sinusoidal signal absolute value third power using digital stochastic method

    Directory of Open Access Journals (Sweden)

    Beljić Željko

    2017-01-01

    Full Text Available In this paper a special case of digital stochastic measurement of the third power of definite integral of sinusoidal signal’s absolute value, using 2-bit AD converters is presented. This case of digital stochastic method had emerged from the need to measure power and energy of the wind. Power and energy are proportional to the third power of wind speed. Anemometer output signal is sinusoidal. Therefore an integral of the third power of sinusoidal signal is zero. Two approaches are proposed for the third power calculation of the wind speed signal. One approach is to use absolute value of sinusoidal signal (before AD conversion for which there is no need of multiplier hardware change. The second approach requires small multiplier hardware change, but input signal remains unchanged. For the second approach proposed minimal hardware change was made to calculate absolute value of the result after AD conversion. Simulations have confirmed theoretical analysis. Expected precision of wind energy measurement of proposed device is better than 0,00051% of full scale. [Project of the Serbian Ministry of Education, Science and Technological Development, Grant no. TR32019

  13. Bilateral robotic priming before task-oriented approach in subacute stroke rehabilitation: a pilot randomized controlled trial.

    Science.gov (United States)

    Hsieh, Yu-Wei; Wu, Ching-Yi; Wang, Wei-En; Lin, Keh-Chung; Chang, Ku-Chou; Chen, Chih-Chi; Liu, Chien-Ting

    2017-02-01

    To investigate the treatment effects of bilateral robotic priming combined with the task-oriented approach on motor impairment, disability, daily function, and quality of life in patients with subacute stroke. A randomized controlled trial. Occupational therapy clinics in medical centers. Thirty-one subacute stroke patients were recruited. Participants were randomly assigned to receive bilateral priming combined with the task-oriented approach (i.e., primed group) or to the task-oriented approach alone (i.e., unprimed group) for 90 minutes/day, 5 days/week for 4 weeks. The primed group began with the bilateral priming technique by using a bimanual robot-aided device. Motor impairments were assessed by the Fugal-Meyer Assessment, grip strength, and the Box and Block Test. Disability and daily function were measured by the modified Rankin Scale, the Functional Independence Measure, and actigraphy. Quality of life was examined by the Stroke Impact Scale. The primed and unprimed groups improved significantly on most outcomes over time. The primed group demonstrated significantly better improvement on the Stroke Impact Scale strength subscale ( p = 0.012) and a trend for greater improvement on the modified Rankin Scale ( p = 0.065) than the unprimed group. Bilateral priming combined with the task-oriented approach elicited more improvements in self-reported strength and disability degrees than the task-oriented approach by itself. Further large-scale research with at least 31 participants in each intervention group is suggested to confirm the study findings.

  14. Measurement of the presampled two-dimensional modulation transfer function of digital imaging systems

    International Nuclear Information System (INIS)

    Fetterly, Kenneth A.; Hangiandreou, Nicholas J.; Schueler, Beth A.; Ritenour, E. Russell

    2002-01-01

    The purpose of this work was to develop methods to measure the presampled two-dimensional modulation transfer function (2D MTF) of digital imaging systems. A custom x-ray 'point source' phantom was created by machining 256 holes with diameter 0.107 mm through a 0.5-mm-thick copper plate. The phantom was imaged several times, resulting in many images of individual x-ray 'spots'. The center of each spot (with respect to the pixel matrix) was determined to subpixel accuracy by fitting each spot to a 2D Gaussian function. The subpixel spot center locations were used to create a 5x oversampled system point spread function (PSF), which characterizes the optical and electrical properties of the system and is independent of the pixel sampling of the original image. The modulus of the Fourier transform of the PSF was calculated. Next, the Fourier function was normalized to the zero frequency value. Finally, the Fourier transform function was divided by the first-order Bessel function that defined the frequency content of the holes, resulting in the presampled 2D MTF. The presampled 2D MTF of a 0.1 mm pixel pitch computed radiography system and 0.2 mm pixel pitch flat panel digital imaging system that utilized a cesium iodide scintillator was measured. Comparison of the axial components of the 2D MTF to one-dimensional MTF measurements acquired using an edge device method demonstrated that the two methods produced consistent results

  15. Unilateral versus bilateral stent insertion for malignant hilar biliary obstruction.

    Science.gov (United States)

    Chang, Gang; Xia, Feng-Fei; Li, Hong-Fu; Niu, Su; Xu, Yuan-Shun

    2017-11-01

    To determine the clinical efficiency and long-term outcomes between unilateral and bilateral stent insertion in patients with malignant hilar biliary obstruction. From August 2012 to February 2016, 63 consecutive patients with malignant hilar biliary obstruction were treated with unilateral or bilateral stent insertion at our center. The bilateral stents were inserted using the side-by-side technique. The clinical efficiency and long-term outcomes were compared between the two groups. Unilateral and bilateral stent insertions were successfully performed in 31 of 33 and 27 of 30 patients, respectively (P = 0.912). No procedure-related complication occurred. Clinical success was achieved in 29 of 31 patients in the unilateral stent group and in 26 of 27 patients in the bilateral stent group (P = 0.637). During the follow-up, re-obstruction of stent occurred in five patients in the unilateral stent group and in three patients in the bilateral stent group (P = 0.58). The significant differences were not observed in the stent patency time (368 vs. 387 days, P = 0.685) and survival (200 vs. 198 days, P = 0.751) between two groups. Based on the univariate and multivariate analyses, the independent risk factors for decreasing the survival time included higher Eastern Cooperative Oncology Group performance status (P = 0.018), higher alanine aminotransferase level (P = 0.009), and absence of anticancer treatment after stent insertion (P = 0.002). Compared to bilateral stent insertion for malignant hilar biliary obstruction, unilateral stent insertion can provide comparable clinical efficiency and long-term outcomes.

  16. DIGITAL MARKETING: SUCCESS METRICS, FUTURE TRENDS

    OpenAIRE

    Preeti Kaushik

    2017-01-01

    Abstract – Business Marketing is one of the prospective which has been tremendously affected by digital world in last few years. Digital marketing refers to doing advertising through digital channels. This paper provides detailed study of metrics to measure success of digital marketing platform and glimpse of future of technologies by 2020.

  17. Immediate Sequential Bilateral Cataract Surgery

    DEFF Research Database (Denmark)

    Kessel, Line; Andresen, Jens; Erngaard, Ditte

    2015-01-01

    The aim of the present systematic review was to examine the benefits and harms associated with immediate sequential bilateral cataract surgery (ISBCS) with specific emphasis on the rate of complications, postoperative anisometropia, and subjective visual function in order to formulate evidence......-based national Danish guidelines for cataract surgery. A systematic literature review in PubMed, Embase, and Cochrane central databases identified three randomized controlled trials that compared outcome in patients randomized to ISBCS or bilateral cataract surgery on two different dates. Meta-analyses were...... performed using the Cochrane Review Manager software. The quality of the evidence was assessed using the GRADE method (Grading of Recommendation, Assessment, Development, and Evaluation). We did not find any difference in the risk of complications or visual outcome in patients randomized to ISBCS or surgery...

  18. A Unified Framework for Measuring Stewardship Practices Applied to Digital Environmental Datasets

    Directory of Open Access Journals (Sweden)

    Ge Peng

    2015-01-01

    Full Text Available This paper presents a stewardship maturity assessment model in the form of a matrix for digital environmental datasets. Nine key components are identified based on requirements imposed on digital environmental data and information that are cared for and disseminated by U.S. Federal agencies by U.S. law, i.e., Information Quality Act of 2001, agencies’ guidance, expert bodies’ recommendations, and users. These components include: preservability, accessibility, usability, production sustainability, data quality assurance, data quality control/monitoring, data quality assessment, transparency/traceability, and data integrity. A five-level progressive maturity scale is then defined for each component associated with measurable practices applied to individual datasets, representing Ad Hoc, Minimal, Intermediate, Advanced, and Optimal stages. The rationale for each key component and its maturity levels is described. This maturity model, leveraging community best practices and standards, provides a unified framework for assessing scientific data stewardship. It can be used to create a stewardship maturity scoreboard of dataset(s and a roadmap for scientific data stewardship improvement or to provide data quality and usability information to users, stakeholders, and decision makers.

  19. International bilateral and multilateral arrangements in energy technologies

    International Nuclear Information System (INIS)

    1978-07-01

    This document, the second report in the series, outlines current DOE international commitments under bilateral and multilateral arrangements, as of January 1, 1978. Included are bilateral agreements for cooperation in the civil uses of atomic energy with countries and international organizations, bilateral and multilateral technical exchanges in all energy technology areas, and multilateral agreements under the auspices of the International Energy Agency (IEA). In addition to outlining the terms, scope, and status of these agreements, this document describes DOE's participation in the work of the major international energy organizations. IEA, the International Atomic Energy Agency (IAEA), and the Nuclear Energy Agency (NEA). Future reports will update the status of ongoing cooperative projects and provide information on new energy R and D activities

  20. Primary and revision efficacy of cross-wired metallic stents for endoscopic bilateral stent-in-stent placement in malignant hilar biliary strictures.

    Science.gov (United States)

    Lee, T H; Moon, J H; Kim, J H; Park, D H; Lee, S S; Choi, H J; Cho, Y D; Park, S H; Kim, S J

    2013-01-01

    Endoscopic bilateral drainage for inoperable malignant hilar biliary strictures (HBS) using metal stents is considered to be technically difficult. Furthermore, endoscopic revision of bilateral stenting after occlusion can be challenging. This study was performed to evaluate the long-term efficacy of endoscopic bilateral stent-in-stent placement of cross-wired metallic stents in high-grade malignant HBS and planned endoscopic bilateral revision. A total of 84 patients with inoperable high-grade malignant HBS were enrolled from three academic tertiary referral centers. Two cross-wired metal stents were inserted using a bilateral stent-in-stent placement method. Bilateral endoscopic revision was also performed during follow-up using either identical metal stents or plastic stents. The main outcome measurements were technical and functional success, complications, stent patency, and endoscopic revision efficacy. The technical and clinical success rates of endoscopic bilateral stent-in-stent placement of cross-wired metallic stents were 95.2% (80/84) and 92.9% (78/84), respectively. Median patency (range) and survival were 238 days (10-429) and 256 days (10-1130), respectively. Obstruction of primary bilateral stents occurred in 30.8% (24/78) of patients with functionally successful stent placement. The technical and clinical success rates of planned bilateral endoscopic revision for occluded stents were 83.3% (20/24) and 79.2% (19/24), respectively. For revision, bilateral metallic stents were placed in 11 patients (55.0%); the remaining patients received plastic stents. Palliative endoscopic bilateral stent-in-stent placement of cross-wired metallic stents was effective in patients with inoperable HBS. Revision endoscopic bilateral stenting may be feasible and successful in cases where the primary deployed metal stents are occluded. © Georg Thieme Verlag KG Stuttgart · New York.

  1. Prolapso de gordura orbitária bilateral associado a pterígio: relato de caso Bilateral orbital fat prolapse associated with pterygium: case report

    Directory of Open Access Journals (Sweden)

    Vanderson Glerian Dias

    2006-06-01

    Full Text Available O prolapso de gordura orbitária é entidade benigna incomum que pode causar defeitos estéticos. Os autores apresentam uma paciente de 63 anos com prolapso de gordura orbitária temporal bilateral associado a pterígio medial bilateral, ressaltando aspectos clínicos e cirúrgicos. Discute-se a importância do diagnóstico clínico e de imagem, além da comprovação histopatológica da lesão.Orbital fat prolapse is an uncommon benign entity that can cause esthetic defects. The authors present a 63-year-old patient with bilateral temporal orbital fat prolapse associated with a bilateral nasal pterygium. Clinical and surgical features are described. The clinical, imaging and histopathological diagnoses are discussed.

  2. Cutaneous metastasis of bilateral renal cell carcinoma.

    Science.gov (United States)

    Abbasi, Fariba; Alizadeh, Mansur; Noroozinia, Farahnaz; Moradi, Amin

    2013-01-01

    Renal cell carcinoma (RCC) is a malignant lethal tumour with high potential of metastasis. However, metastasis from RCC to the skin is much less common. It is virtually a sign of poor prognosis. We represent a 42 years old man with bilateral RCC of clear cell type followed by metastasis to the scalp one month later. In this case the relatively young age of the patient, bilaterality of RCC and occurance of skin metastasis in the absence of recurrent kidney tumour are interesting.

  3. BILATERAL CHOROIDAL EXCAVATION IN JUVENILE LOCALIZED SCLERODERMA.

    Science.gov (United States)

    Franklin, Mackenzie L; Day, Shelley

    2018-01-01

    To describe a case of bilateral choroidal excavation in a patient with juvenile localized scleroderma. Case report. An asymptomatic 12-year-old boy with localized scleroderma presented for examination and was found to have bilateral areas of choroidal excavation temporal to the fovea. Previous reports of ocular complications of localized scleroderma have primarily described adnexal and anterior segment changes. This is the second report of choroidal changes in a patient with localized scleroderma, and the first in a pediatric patient.

  4. Measurements of oil spill spreading in a wave tank using digital image processing

    International Nuclear Information System (INIS)

    Flores, H.; Saavedra, I.; Andreatta, A.; Llona, G.

    1998-01-01

    In this work, an experimental study of spreading of crude oil is carried out in a wave tank. The tests are performed by spilling different volumes and types of crude oil on the water surface. An experimental measurement technique was developed based on digital processing of video images. The acquisition and processing of such images is carried out by using a video camera and inexpensive microcomputer hardware and software. Processing is carried out by first performing a digital image filter, then edge detection is performed on the filtered image data. The final result is a file that contains the coordinates of a polygon that encloses the observed slick for each time step. Different types of filters are actually used in order to adequately separate the color intensifies corresponding to each of the elements in the image. Postprocessing of the vectorized images provides accurate measurements of the slick edge, thus obtaining a complete geometric representation, which is significantly different from simplified considerations of radially symmetric spreading. The spreading of the oil slick was recorded for each of the tests. Results of the experimental study are presented for each spreading regime, and analyzed in terms of the wave parameters such as period and wave height. (author)

  5. Measurement of the Young's modulus of thin or flexible specimen with digital-image correlation method

    Science.gov (United States)

    Xu, Lianyun; Hou, Zhende; Qin, Yuwen

    2002-05-01

    Because some composite material, thin film material, and biomaterial, are very thin and some of them are flexible, the classical methods for measuring their Young's moduli, by mounting extensometers on specimens, are not available. A bi-image method based on image correlation for measuring Young's moduli is developed in this paper. The measuring precision achieved is one order enhanced with general digital image correlation or called single image method. By this way, the Young's modulus of a SS301 stainless steel thin tape, with thickness 0.067mm, is measured, and the moduli of polyester fiber films, a kind of flexible sheet with thickness 0.25 mm, are also measured.

  6. Digital divide and digital opportunity: Comparison, analysis and strategies for sustainable development in developing nations

    International Nuclear Information System (INIS)

    Bhunia, C.T.; Onime, C.

    2007-07-01

    The world is witnessing a new digital economic order which may be quantified by the diffusion of information technology and globalization process. The current information technology gap (digital divide) between developed countries and developing countries is huge. Improvements in information technology (measured by the digital opportunity index) usually open up an opportunity for national/regional growth and development. There is a need for scientific investigation on the digital divide, digital opportunity index and their consequences. This paper presents a critical analysis of existing digital divide and its trends, it also investigates the relationship between the digital divide and the digital opportunity index. A mathematical model based on analysis of the growing digital divide is presented as a possible tool for combating and eradicate the digital divide gap which is only possible if developing and poor nations take advantage of the digital opportunities that can transform them into global competitive partners in digital knowledge economy. (author)

  7. Pneumomediastinum and bilateral pneumothorax following near drowning in shallow water

    Directory of Open Access Journals (Sweden)

    Santhiya Govindaraj

    2011-10-01

    Full Text Available We report pneumomediastinum, bilateral pneumothorax and acute respiratory distress syndrome in a victim of near drowning who was intoxicated and did not have thoracic or neck trauma. Chest radiograph revealed the above findings, later confirmed by computed tomography. He was in shock and also had gastrointestinal (GI bleeding and renal dysfunction. With adequate resuscitative measures including fluids, blood transfusions, intercostal tube drainage and mechanical ventilation he made a complete recovery. Good prognostic indicators in near drowning patients include higher Glasgow Coma Scale, short submersion time and quick resuscitative measures even in the presence of serious cardiorespiratory or hemodynamic compromise.

  8. Pneumomediastinum and bilateral pneumothorax following near drowning in shallow water

    Directory of Open Access Journals (Sweden)

    Stalin Viswanathan

    2011-09-01

    Full Text Available We report pneumomediastinum, bilateral pneumothorax and acute respiratory distress syndrome in a victim of near drowning who was intoxicated and did not have thoracic or neck trauma. Chest radiograph revealed the above findings, later confirmed by computed tomography. He was in shock and also had gastrointestinal (GI bleeding and renal dysfunction. With adequate resuscitative measures including fluids, blood transfusions, intercostal tube drainage and mechanical ventilation he made a complete recovery. Good prognostic indicators in near drowning patients include higher Glasgow Coma Scale, short submersion time and quick resuscitative measures even in the presence of serious cardiorespiratory or hemodynamic compromise.

  9. Measuring food intake with digital photography

    OpenAIRE

    Martin, Corby K.; Nicklas, Theresa; Gunturk, Bahadir; Correa, John B.; Allen, H. Raymond; Champagne, Catherine

    2013-01-01

    The Digital Photography of Foods Method accurately estimates the food intake of adults and children in cafeterias. When using this method, imags of food selection and leftovers are quickly captured in the cafeteria. These images are later compared to images of “standard” portions of food using a computer application. The amount of food selected and discarded is estimated based upon this comparison, and the application automatically calculates energy and nutrient intake. Herein, we describe th...

  10. Reliability-guided digital image correlation for image deformation measurement

    International Nuclear Information System (INIS)

    Pan Bing

    2009-01-01

    A universally applicable reliability-guided digital image correlation (DIC) method is proposed for reliable image deformation measurement. The zero-mean normalized cross correlation (ZNCC) coefficient is used to identify the reliability of the point computed. The correlation calculation begins with a seed point and is then guided by the ZNCC coefficient. That means the neighbors of the point with the highest ZNCC coefficient in a queue for computed points will be processed first. Thus the calculation path is always along the most reliable direction, and possible error propagation of the conventional DIC method can be avoided. The proposed novel DIC method is universally applicable to the images with shadows, discontinuous areas, and deformation discontinuity. Two image pairs were used to evaluate the performance of the proposed technique, and the successful results clearly demonstrate its robustness and effectiveness

  11. A case misdiagnosed as bilateral abducens palsy

    International Nuclear Information System (INIS)

    Takeda, Naoya; Kuwamura, Keiichi; Shirataki, Kunio; Tamaki, Norihiko; Matsumoto, Satoshi

    1984-01-01

    A 66-year-old male was admitted to our neurosurgical floor because of double vision and gait disturbance. Neurological examinations revealed bilateral 6th nerve palsy with both eyes pointing toward the midline. Initially, using a tentative diagnosis of intracranial mass lesions, especially localized at the base of the skull, computerized tomography of the head, cerebral angiography, orbital venography, and metrizamide CT cisternography were performed; the findings were normal. An orbital CT scan showed an enlargement of the bilateral medial rectus muscles, and the thyroid functions of T 3 and T 4 and the T 3 uptake were all elevated, which was compatible with the diagnosis of Graves' disease. The limitations of both eyeballs were considered to be due not to the 6th nerve palsy, but to the hypertrophy of the bilateral medial rectus muscles. We neurosurgeons should recall Graves' disease as well as intracranial lesions, cerebrovascular disease, and post-traumatic sequelae when examining a patient who presents limitations of external ocular movement. (author)

  12. Bilateral clear cell sarcoma of the kidney

    International Nuclear Information System (INIS)

    Zekri, W.; Yehia, D.; Alfaar, A.S.; Elshafie, M.M.; Younes, A.A.; Zaghloul, M.S.; El-Kinaai, N.; Taha, H.; Refaat, A.; Zekri, W.; Elshafie, M.M.; Zaghloul, M.S.; Taha, H.; Refaat, A.; Younes, A.A.; Alfaar, A.S.; Yehia, D.

    2015-01-01

    Clear cell sarcoma of the kidney (CCSK) accounts for 2-5% of all pediatric renal malignancies, and is known for its propensity to metastasize to bone and other sites. We are reporting two cases with bilateral CCSK that were diagnosed at our institution. One patient initially presented with bilateral renal masses, as well as pulmonary, hepatic and bone metastasis; while other present only with bilateral masses with no evident distant metastasis. Both patients received aggressive neo-adjuvant chemotherapy to decrease tumor size. One patient completed his designated treatment and initially showed complete remission (CR); eventually suffering from relapse. The other patient’s tumor progressed during the course of chemotherapy. Both cases manifested brain dissemination at the time of relapse or progression. This emphasizes the importance of staging stratification in CCSK. This also illustrates CCSK’s ability to metastasize to bone and other sites including the brain (a primary relapse site in our cases)

  13. Post appendectomy acalculus bilateral ureteric obstruction: A rare entity in children

    Directory of Open Access Journals (Sweden)

    Vipul Gupta

    2013-01-01

    Full Text Available Bilateral acalculus ureteric obstruction is described as rare sequelae of acute appendicitis in two paediatric patients aged 6 and 11 years presented with features of anuria. Imaging and endoscopic evaluation confirmed bilateral ureteric obstruction secondary to bladder wall oedema as an inflammatory reaction to appendix. Both cases recovered following bilateral ureteric stenting and are doing well.

  14. Digital Measuring Devices Used for Injector Hydraulic Test

    Directory of Open Access Journals (Sweden)

    S. N. Leontiev

    2015-01-01

    Full Text Available To ensure a high specific impulse of the LRE (liquid-propellant engine chamber it is necessary to have optimally organized combustion of the fuel components. This can be ensured by choosing the optimum geometry of gas-dynamic contour of the LRE combustor, as well as by improving the sputtering processes and mixing the fuel components, for example, by selection of the optimum type, characteristics, and location of injectors on the mixing unit of the chamber.These particular reasons arise the interest in the injector characteristics in terms of science, and technological aspects determine the need for control of underlying design parameters in their manufacture.The objective of this work is to give an experimental justification on used digital measurement instrumentation and research the hydraulic characteristics of injectors.To determine injector parameters most widely were used the units with sectional collectors. A technique to control injector parameters using the sectional collectors involves spraying the liquid by injector at a given pressure drop on it for a certain time (the longer, the higher the accuracy and reliability of the results and then determining the amount of liquid in each section to calculate the required parameters of injector.In this work the liquid flow through the injector was determined by high-precision flowmeters FLONET FN2024.1 of electromagnetic type, which have very high metrological characteristics, in particular a flow rate error does not exceed 0.5% in a range of water flow from Qmin= 0.0028 l/s to Qmax Qmax = 0.28 l/s. To determine the coefficient of uneven spray were used differential pressure sensors DMD 331-ASLX of company "DB Sensors RUS", which have an error of 0.075% with a range of differential pressure 0 ... 5 kPa. Measuring complex MIC-200 of company "NPP Measure" and WinPos software for processing array information provided entry, recording, and processing of all the data of the experiment.In this

  15. Bilateral leukocoria in a patient with homozygous protein C deficiency

    International Nuclear Information System (INIS)

    Khan, Nasrat M.; Al-Dohayan, Noura D.; Al-Batiniji, Fatima S.

    2007-01-01

    We describe a bilateral leukocoria and neonatal purpura fulminans in a male infant, born at full term after an unremarkable pregnancy to a healthy consanguineous married couple. Multiple hemorrhagic skin bullae were found at birth on various parts of the body with bilateral leukocoria, organized vitreous hemorrhage, retinal detachment, and intracranial hemorrhage with undetectable levels of protein C activity. We report a clinical case of homozygous protein-C deficiency with severe purpura fulminans and bilateral leukocoria. (author)

  16. The development of digital oscilloscope control software in nuclear measurement

    International Nuclear Information System (INIS)

    Pu Minghui; Tian Geng; Li Xianyou

    2004-01-01

    This essay presents the development of an all-purpose digital oscilloscope control software on Windows 95/98 OS. The background and method are discussed in detail, together with the function and characteristics of the software. With the use of this software, a single PC can control several digital oscilloscopes. Solution of main problems encountered in the development is also discussed. (authors)

  17. Long-term functional outcome of bilateral spontaneous and simultaneous Achilles tendon ruptures.

    LENUS (Irish Health Repository)

    Ellanti, Prasad

    2012-10-01

    Bilateral simultaneous ruptures are rare comprising less than 1% of all Achilles tendon ruptures. Risk factors for bilateral ruptures include chronic diseases and medications such as corticosteroids and fluoroquinolones. There is little in the literature on the long-term functional outcome of bilateral Achilles tendon ruptures. This article present a series of 3 cases of simultaneous and spontaneous bilateral Achilles tendon ruptures with a minimum of 5-year follow up suggesting a good functional outcome.

  18. Bilateral Periventricular Nodular Heterotopia

    OpenAIRE

    J Gordon Millichap

    1998-01-01

    Two unrelated boys, ages 8 and 5 years, with a syndrome of bilateral periventricular nodular heterotopia (BPNH), regional cortical dysplasia, mild mental retardation, and frontonasal malformation (FNM) are reported from the Instituto di Neuropsychiatria Infantile, University of Pisa, Italy, and the Institute of Human Genetics, University of Minnesota Medical School, Minneapolis, MN.

  19. Bilateral teleoperation for linear force sensorless 3D robots

    NARCIS (Netherlands)

    Lichiardopol, S.; Wouw, van de N.; Nijmeijer, H.; Andrade Cetto, J.; Ferrier, J.; Filipe, J.

    2011-01-01

    It is well known that for bilateral teleoperation, force feedback information is needed. In this paper, we propose a control approach for bilateral teleoperation with uncertainties in the model of the slave robot and which does not use force sensors for haptic feedback. The controller design is

  20. Simultaneous Bilateral Bell's palsy in a Nigerian man | Owolabi ...

    African Journals Online (AJOL)

    Bilateral Bellfs palsy occurring simultaneously is exceedingly rare. We report a case of a 27.year.old Nigerian man with bilateral Bellfs palsy, that occurred simultaneously, who had remarkable response to steroid and physiotherapy. We emphasized the importance of considering Bellfs palsy and the various differential ...

  1. Fast collimated neutron flux measurement using stilbene scintillator and flashy analog-to-digital converter in JT-60U

    International Nuclear Information System (INIS)

    Ishikawa, M.; Itoga, T.; Okuji, T.; Nakhostin, M.; Shinohara, K.; Hayashi, T.; Sukegawa, A.; Baba, M.; Nishitani, T.

    2006-01-01

    A line-integrated neutron emission profile is routinely measured using the radial neutron collimator system in JT-60U tokamak. Stilbene neuron detectors (SNDs), which combine a stilbene organic crystal scintillation detector (SD) with an analog neutron-gamma pulse shape discrimination (PSD) circuit, have been used to measure collimated neutron flux. Although the SND has many advantages as a neutron detector, the maximum count rate is limited up to ∼1x10 5 counts/s due to the analog PSD circuit. To overcome this issue, a digital signal processing system (DSPS) using a flash analog-to-digital converter (Acqiris DC252, 8 GHz, 10 bits) has been developed at Cyclotron and Radioisotope Center in Tohoku University. In this system anode signals from photomultiplier of the SD are directory stored and digitized. Then, the PSD between neutrons and gamma rays is performed using software. The DSPS has been installed in the vertical neutron collimator system in JT-60U and applied to deuterium experiments. It is confirmed that the PSD is sufficiently performed and collimated neutron flux is successfully measured with count rate up to ∼5x10 5 counts/s without the effect of pileup of detected pulses. The performance of the DSPS as a neutron detector, which supersedes the SND, is demonstrated

  2. Bilateral parotitis as the initial presentation of childhood sarcoidosis.

    Science.gov (United States)

    Banks, Gretchen C; Kirse, Daniel J; Anthony, Evelyn; Bergman, Simon; Shetty, Avinash K

    2013-01-01

    The differential diagnosis of bilateral parotid gland enlargement in children includes infectious, inflammatory, and neoplastic disorders. We present the case of a 13-year-old male who presented with a 5-week history of bilateral parotid swelling. On exam, both parotid glands were nontender, smooth, and diffusely enlarged. He had slightly elevated inflammatory markers, but other lab results were normal. A neck CT revealed symmetric enlargement of the parotid, submandibular, and sublingual glands. A chest CT revealed scattered peripheral pulmonary nodules and bilateral hilar adenopathy. A parotid gland biopsy showed multiple noncaseating granulomas with multinucleated giant cells surrounded by lymphocytes, consistent with the diagnosis of sarcoidosis. Special stains for acid-fast and fungal organisms were negative. Using this illustrative case, we discuss the differential diagnosis of bilateral salivary gland enlargement in children and review the etiology, diagnosis, clinical manifestations, and treatment of pediatric sarcoidosis. Copyright © 2013 Elsevier Inc. All rights reserved.

  3. Delayed diagnosis of homocystinuria presenting as bilateral congenital lens subluxation

    Directory of Open Access Journals (Sweden)

    Jelić-Vuković Marija

    2017-01-01

    Full Text Available Introduction. Homocystinuria is an autosomal recessively inherited defect leading to hyperhomocysteinemia and associated with ocular manifestations, mainly myopia and ectopia lentis. Case outline. A 26-year-old male with secondary glaucoma due to bilateral lens subluxation was admitted to the Department of vitreoretinal surgery. Horizontal nystagmus, bilateral lens subluxation, and bilateral amblyopia were first discovered at the age of three years. Preoperative laboratory workup revealed elevated levels of homocysteine. Bilateral pars plana lensectomy and vitrectomy followed by a sulcus fixation of the intraocular lens (ALCON MA60 Acrysof IOL were performed. The patient was prescribed folic acid, methionine, and pyridoxine, and was urged to maintain a methionine-low diet. After a bilateral lensectomy and sulcus fixation of the intraocular lens and a methionine restriction therapy combined with vitamin B6, B9, and B12 supplementation, his condition improved greatly. Conclusion. In this report of a rare case we emphasize the importance of examining differential diagnoses of lens subluxation, since early intervention can prevent serious complications.

  4. Fast transient digitizer

    International Nuclear Information System (INIS)

    Villa, F.

    1982-01-01

    Method and apparatus for sequentially scanning a plurality of target elements with an electron scanning beam modulated in accordance with variations in a high-frequency analog signal to provide discrete analog signal samples representative of successive portions of the analog signal; coupling the discrete analog signal samples from each of the target elements to a different one of a plurality of high speed storage devices; converting the discrete analog signal samples to equivalent digital signals; and storing the digital signals in a digital memory unit for subsequent measurement or display

  5. A case of simultaneous bilateral spontaneous pneumothorax after the Nuss procedure.

    Science.gov (United States)

    Matsuoka, Shunichiro; Miyazawa, Masahisa; Kashimoto, Kentaro; Kobayashi, Hiroaki; Mitsui, Fumihiko; Tsunoda, Hajime; Kunitomo, Kazuyoshi; Chisuwa, Hisanao; Haba, Yoshiaki

    2016-06-01

    We present a case of simultaneous bilateral spontaneous pneumothorax caused by a pleuro-pleural communication formed from Nuss procedure for pectus excavatum. A 17-year-old man with a history of Nuss operation complained chest pain and dyspnea. A chest roentgenogram demonstrated a tiny bilateral pneumothorax and two metallic bars inserted at the Nuss procedure. Computed tomography revealed furthermore a bulla in the apex of the left lung. The bilateral pneumothorax critically deteriorated after 4 days from onset and urgent bilateral chest drainages were performed. Nevertheless the drainages the full expansion of both lungs was not obtained and air leakage only from left side was continued. A video-assisted left bullectomy was performed 9 days after the tube insertion. The two bars penetrating anterior mediastinal pleura were thought to be a cause of the simultaneous bilateral spontaneous pneumothorax.

  6. Prolapsed bilateral ureteroceles leading to intermittent outflow obstruction.

    LENUS (Irish Health Repository)

    Stunell, H

    2012-02-01

    A ureterocele refers to a cystic dilatation of the distal ureter. It may be unilateral or bilateral and may be associated with a duplex system in some cases. We present an unusual case where a young patient was found to have large bilateral ureteroceles which prolapsed into the urethra, causing intermittent incontinence and obstruction. We discuss the case and review the literature concerning this rare anomaly.

  7. Amyad's hernia while reparing the bilateral inguinal hernia

    OpenAIRE

    Arif Aslaner; Tuğrul Çakır; Umut Rıza Gündüz; Burhan Mayir; Nurullah Bülbüller

    2015-01-01

    Amyand's hernia is the term used for inguinal hernia containing appendix. It is a rare condition and found in 1% of inguinal hernia repairs. Here we report a case of Amyand's hernia in a 61 years old male who was diagnosed with bilateral inguinal hernia. He underwent surgery and bilateral inguinal hernia repair with prosthetic meshes and without appendectomy. The patient was discharged uneventfully. 

  8. Analysis and improvement of digital control stability for master-slave manipulator system

    International Nuclear Information System (INIS)

    Yoshida, Koichi; Yabuta, Tetsuro

    1992-01-01

    Some bilateral controls of master-slave system have been designed, which can realize high-fidelity telemanipulation as if the operator were manipulating the object directly. While usual robot systems are controlled by software-servo system using digital computer, little work has been published on design and analysis for digital control of these systems, which must consider time-delay of sensor signals and zero order hold effect of command signals on actuators. This paper presents a digital control analysis for single degree of freedom master-slave system including impedance models of both the human operator and the task object, which clarifies some index for the stability. The stability result shows a virtual master-slave system concepts, which improve the digital control stability. We first analyze a dynamic control method of master-slave system in discrete-time system for the stability problem, which can realize high-fidelity telemanipulation in the continuous-time. Secondly, using the results of the stability analysis, the robust control scheme for master-slave system is proposed, and the validity of this scheme is finally confirmed by the simulation. Consequently, it would be considered that any combination of master and slave modules with dynamic model of these manipulators is possible to construct the stable master-slave system. (author)

  9. A digital transducer and digital microphone using an optical technique

    Science.gov (United States)

    Ghelmansarai, F. A.

    1996-09-01

    A transducer is devised to measure pressure, displacements or angles by optical means. This transducer delivers a digital output without relying on interferometry techniques or analogue-to-digital converters. This device is based on an optical scanner and an optical detector. An inter-digital photoconductive detector (IDPC) is employed that delivers a series of pulses, whose number depends on the scan length. A pre-objective scanning configuration is used that allows for the possibility of a flat image plane. The optical scanner provides scanning of IDPC and the generated scan length is proportional to the measurand.

  10. Clinical performance evaluation of total protein measurement by digital refractometry and characterization of non-protein solute interferences.

    Science.gov (United States)

    Hunsaker, Joshua J H; Wyness, Sara P; Snow, Taylor M; Genzen, Jonathan R

    2016-12-01

    Refractometric methods to measure total protein (TP) in serum and plasma specimens have been replaced by automated biuret methods in virtually all routine clinical testing. A subset of laboratories, however, still report using refractometry to measure TP in conjunction with serum protein electrophoresis. The objective of this study was therefore to conduct a modern performance evaluation of a digital refractometer for TP measurement. Performance evaluation of a MISCO Palm Abbe™ digital refractometer was conducted through device familiarization, carryover, precision, accuracy, linearity, analytical sensitivity, analytical specificity, and reference interval verification. Comparison assays included a manual refractometer and an automated biuret assay. Carryover risk was eliminated using a demineralized distilled water (ddH 2 O) wash step. Precision studies demonstrated overall imprecision of 2.2% CV (low TP pool) and 0.5% CV (high TP pool). Accuracy studies demonstrated correlation to both manual refractometry and the biuret method. An overall positive bias (+5.0%) was observed versus the biuret method. On average, outlier specimens had an increased triglyceride concentration. Linearity was verified using mixed dilutions of: a) low and high concentration patient pools, or b) albumin-spiked ddH 2 O and high concentration patient pool. Decreased recovery was observed using ddH 2 O dilutions at low TP concentrations. Significant interference was detected at high concentrations of glucose (>267 mg/dL) and triglycerides (>580 mg/dL). Current laboratory reference intervals for TP were verified. Performance characteristics of this digital refractometer were validated in a clinical laboratory setting. Biuret method remains the preferred assay for TP measurement in routine clinical analyses.

  11. A Case of Bilateral Pigment Dispersion Syndrome Following Many Years of Uninterrupted Treatment With Atropine 1% for Bilateral Congenital Cataracts.

    Science.gov (United States)

    Gizzi, Corrado; Mohamed-Noriega, Jibran; Murdoch, Ian

    2017-10-01

    Describe an unusual case of bilateral pigment dispersion syndrome (PDS) following years of uninterrupted treatment with atropine 1% for bilateral congenital cataracts, speculate on potential mechanisms leading to this condition. This is a case report. A 45-year-old white patient on long-term treatment with atropine 1% ointment since his infancy for bilateral congenital cataracts developed PDS with secondary ocular hypertension. The patient showed all the hallmarks of PDS with secondary ocular hypertension. An anterior segment Swept-Source optical coherence tomography was obtained to review the iris profile. The patient showed good pressure response to topical prostaglandin therapy. This is the second case report of PDS in a patient with chronic use of topical atropine. The proposed mechanisms for pigment dispersion are discussed and the possibility raised of dispersion being a potential side effect of the drug.

  12. Electrical crosstalk-coupling measurement and analysis for digital closed loop fibre optic gyro

    International Nuclear Information System (INIS)

    Jing, Jin; Hai-Ting, Tian; Xiong, Pan; Ning-Fang, Song

    2010-01-01

    The phase modulation and the closed-loop controller can generate electrical crosstalk-coupling in digital closed-loop fibre optic gyro. Four electrical cross-coupling paths are verified by the open-loop testing approach. It is found the variation of ramp amplitude will lead to the alternation of gyro bias. The amplitude and the phase parameters of the electrical crosstalk signal are measured by lock-in amplifier, and the variation of gyro bias is confirmed to be caused by the alternation of phase according to the amplitude of the ramp. A digital closed-loop fibre optic gyro electrical crosstalk-coupling model is built by approximating the electrical cross-coupling paths as a proportion and integration segment. The results of simulation and experiment show that the modulation signal electrical crosstalk-coupling can cause the dead zone of the gyro when a small angular velocity is inputted, and it could also lead to a periodic vibration of the bias error of the gyro when a large angular velocity is inputted

  13. Bilateral Free Flap Breast Reconstruction Outcomes: Do Abdominal Scars Affect Bilateral Flaps?

    Directory of Open Access Journals (Sweden)

    Dmytro Unukovych, MD, PhD

    2017-09-01

    Conclusion:. Surgical outcomes of bilateral reconstructions in patients with abdominal scars are generally comparable with ones in patients without prior surgery; however, some problems have been identified. These procedures might have some intraoperative considerations and often require increased operative times. Apart from the traditional preoperative computed tomography angiography, intraoperative imaging (e.g., fluorescence angiography may be advocated in patients with abdominal scars.

  14. Bilateral femoral head dysplasia and osteochondritis. Multiple epiphyseal dysplasia tarda, spondylo-epiphyseal dysplasia tarda, and bilateral Legg-Perthes disease

    Energy Technology Data Exchange (ETDEWEB)

    Andersen, P.E. Jr.; Schantz, K.; Bollerslev, J.; Justesen, P.

    Multiple epiphyseal dysplasia tarda (MEDT) and spondylo-epiphyseal dysplasisa tarda (SEDT) are genetically transmitted conditions affecting the hips, which may resemble bilateral Legg-Perthes disease (LPD). Misdiagnoses are not uncommon, with serious implications for treatment, prognosis and genetic counseling. An epidemiologic study of MEDT and SEDT in a well-defined population of 453 921 persons in Denmark was performed. A population prevalence of 0.7 per 100 000 inhabitants with SEDT and 4.0 per 100 000 inhabitants with MEDT was found. Distinguishing features between MEDT, SEDT and bilateral LPD based on radiologic findings in the hips, other joints, and spine were ascertained. Bilateral LPD is always asymmetric, exhibits patches of increased density in the epiphyses and often metaphyseal cyst-like changes. No spinal lesion or affection of other joints is present, and the acetabula are normal. In MEDT and SEDT the capital femoral epiphyses are symmetrically flattened, fragmented and uniformly slightly sclerotic. Generalised platyspondyly is a constant finding in SEDT.

  15. Feocromocitoma bilateral: la importancia de los estudios de diagnóstico por imagen Bilateral pheochromocytoma: the importance of imaging studies

    Directory of Open Access Journals (Sweden)

    Igor I Bonnet

    2011-10-01

    Full Text Available Se presenta un caso clínico poco frecuente de feocromocitoma bilateral, en el cual los estudios de diagnóstico por imagen, tanto de información estructural como funcional, constituyeron una fuente fundamental para su detección y seguimiento.We report a rare case of bilateral pheochromocytoma, in which imaging studies, both of structural and functional information, were a major source for its detection and follow-up.

  16. Efficacy of breast conservation therapy in early stage bilateral breast cancer

    International Nuclear Information System (INIS)

    Lee, Misa M.; Chen, Luci M.; Heimann, Ruth; Powers, Claire; Weichselbaum, Ralph R.

    1996-01-01

    PURPOSE: To evaluate outcome of patients with bilateral breast cancer as compared to unilateral breast cancer treated with breast conservation therapy. This is a complex issue, however, we address this by comparing (1) synchronous bilateral breast cancer patients, (2) metachronous bilateral breast cancer patients from the time of diagnosis of the second breast primary, and (3) unilateral breast cancer patients. The authors recognize that there are inherent biases in these comparisons. MATERIALS AND METHODS: A total of 60 bilateral patients and 1080 unilateral patients treated with breast conservation therapy from 1977-1994 were analyzed for outcome. Of the 60 bilateral patients, 44 were metachronous bilateral breast cancer patients (MBBC) and 16 were synchronous breast cancer patients (SBBC). Patients with bilateral breast cancer had local-regional disease with the following tumor stages: DCIS=8%, T1=80%, T2=12%, pathologic N0=90%, pathologic N+=10%. Unilateral patients had the following tumor stages: DCIS=10%, T1=66%, T2=20%, T3=1.2%, Tx=2%, pathological N0=80%, pathological N+=19%, and NX=1%. The majority of patients received lumpectomy and axillary node dissection followed by radiation therapy. The median size of the lesions were 1.4cm and 1.5cm for bilateral and unilateral patients, respectively. Median total dose to the primary tumor was 60Gy for both unilateral and bilateral patients. Of the 44 metachronous bilateral breast cancer patients, 14 patients received breast conservation for both the first and second lesions while 30 patients had breast conservation for only the second metachronous breast lesion. Thus 58 lesions in the 44 patients were treated with breast conservation therapy in the patients with metachronous bilateral breast cancer. Of the synchronous bilateral breast cancer patients, 13 out of 16 patients had breast conserving therapy for both breasts, and 3 patients received mastectomy for the second synchronous breast tumor. The median follow

  17. Blunt bilateral diaphragmatic rupture—A right side can be easily missed

    Directory of Open Access Journals (Sweden)

    Maria Michailidou

    2015-12-01

    Full Text Available Blunt diaphragmatic rupture (BDR is uncommon with a reported incidence range of 1%–2%. The true incidence is not known. Bilateral BDR is particularly rare. We presented a case of bilateral BDR and we think that the incidence is under-recognised thanks to an easily missed and difficult to diagnose right sided injury. Keywords: Blunt, Diaphragm, Bilateral, Injury

  18. MEASURING AIR AND TERRESTRIAL TRANSPORT COMPANY REPUTATION: TOURISM INTANGIBLES EXPRESSED IN THE DIGITAL ENVIRONMENT

    Directory of Open Access Journals (Sweden)

    Célia M.Q. Ramos

    2017-12-01

    Full Text Available The reputation of companies within the transport industry is influenced by competitive dynamics within the sector: low-cost flights, the attractiveness of destinations, online user-generated content about users’ experiences, and more. At the same time, social media provides a means for companies to manage issues of tourism intangibles. Thus, it is relevant to analyse transport reputation in the digital environment, taking into consideration the resources for managing these intangibles. This paper presents a method for measuring transport reputation based on an analysis of tourism consumers’ digital opinions and passengers’ comments about their experiences with these firms. The use of social media, such as TripAdvisor and Facebook, conjugated with business intelligence tools and complemented by data mining techniques, can contribute to the development of metrics that consider intangibles like emotions and experiences, with the aim of measuring, analysing, and visualizing the complex relationships between these intangibles and transport companies’ reputations. The results present the impacts of these intangibles through clusters and positioning maps focusing on these issues. This investigation contributes to our knowledge about airlines and terrestrial transport companies that seek to differentiate their positioning in tourism markets through their reputations.

  19. Bilateral Olecranon Tophaceous Gout Bursitis

    Directory of Open Access Journals (Sweden)

    Güzelali Özdemir

    2017-01-01

    Full Text Available In this case, we present a patient with the diagnosis of bilateral olecranon tophaceous gout. After the surgical treatment, there was no limitation of range of motion or wound problem at 6th month control.

  20. Specific Changes in Young Soccer Player's Fitness After Traditional Bilateral vs. Unilateral Combined Strength and Plyometric Training.

    Science.gov (United States)

    Ramirez-Campillo, Rodrigo; Sanchez-Sanchez, Javier; Gonzalo-Skok, Oliver; Rodríguez-Fernandez, Alejandro; Carretero, Manuel; Nakamura, Fabio Y

    2018-01-01

    The aim of this study was to compare changes in young soccer player's fitness after traditional bilateral vs. unilateral combined plyometric and strength training. Male athletes were randomly divided in two groups; both received the same training, including strength training for knee extensors and flexors, in addition to horizontal plyometric training drills. The only difference between groups was the mode of drills technique: unilateral (UG; n = 9; age, 17.3 ± 1.1 years) vs. bilateral (TG; n = 9; age, 17.6 ± 0.5 years). One repetition maximum bilateral strength of knee muscle extensors (1RM_KE) and flexors (1RM_KF), change of direction ability (COD), horizontal and vertical jump ability with one (unilateral) and two (bilateral) legs, and limb symmetry index were measured before and after an 8-week in-season intervention period. Some regular soccer drills were replaced by combination of plyometric and strength training drills. Magnitude-based inference statistics were used for between-group and within-group comparisons. Beneficial effects ( p plyometric training should be complemented with unilateral drills, in order to maximize adaptations.