WorldWideScience

Sample records for bilateral cochlear implants

  1. Bilateral cochlear implantation in a patient with bilateral temporal bone fractures.

    Science.gov (United States)

    Chung, Jae Ho; Shin, Myung Chul; Min, Hyun Jung; Park, Chul Won; Lee, Seung Hwan

    2011-01-01

    With the emphasis on bilateral hearing nowadays, bilateral cochlear implantation has been tried out for bilateral aural rehabilitation. Bilateral sensorineural hearing loss caused by head trauma can get help from cochlear implantation. We present the case of a 44-year-old man with bilateral otic capsule violating temporal bone fractures due to head trauma. The patient demonstrated much improved audiometric and psychoacoustic performance after bilateral cochlear implantation. We believe bilateral cochlear implantation in such patient can be a very effective tool for rehabilitation. Copyright © 2011 Elsevier Inc. All rights reserved.

  2. Tinnitus after Simultaneous and Sequential Bilateral Cochlear Implantation.

    Science.gov (United States)

    Ramakers, Geerte G J; Kraaijenga, Véronique J C; Smulders, Yvette E; van Zon, Alice; Stegeman, Inge; Stokroos, Robert J; Free, Rolien H; Frijns, Johan H M; Huinck, Wendy J; Van Zanten, Gijsbert A; Grolman, Wilko

    2017-01-01

    There is an ongoing global discussion on whether or not bilateral cochlear implantation should be standard care for bilateral deafness. Contrary to unilateral cochlear implantation, however, little is known about the effect of bilateral cochlear implantation on tinnitus. To investigate tinnitus outcomes 1 year after bilateral cochlear implantation. Secondarily, to compare tinnitus outcomes between simultaneous and sequential bilateral cochlear implantation and to investigate long-term follow-up (3 years). This study is a secondary analysis as part of a multicenter randomized controlled trial. Thirty-eight postlingually deafened adults were included in the original trial, in which the presence of tinnitus was not an inclusion criterion. All participants received cochlear implants (CIs) because of profound hearing loss. Nineteen participants received bilateral CIs simultaneously and 19 participants received bilateral CIs sequentially with an inter-implant interval of 2 years. The prevalence and severity of tinnitus before and after simultaneous and sequential bilateral cochlear implantation were measured preoperatively and each year after implantation with the Tinnitus Handicap Inventory (THI) and Tinnitus Questionnaire (TQ). The prevalence of preoperative tinnitus was 42% (16/38). One year after bilateral implantation, there was a median difference of -8 (inter-quartile range (IQR): -28 to 4) in THI score and -9 (IQR: -17 to -9) in TQ score in the participants with preoperative tinnitus. Induction of tinnitus occurred in five participants, all in the simultaneous group, in the year after bilateral implantation. Although the preoperative and also the postoperative median THI and TQ scores were higher in the simultaneous group, the median difference scores were equal in both groups. In the simultaneous group, tinnitus scores fluctuated in the 3 years after implantation. In the sequential group, four patients had an additional benefit of the second CI: a total

  3. Tinnitus after Simultaneous and Sequential Bilateral Cochlear Implantation

    Directory of Open Access Journals (Sweden)

    Geerte G. J. Ramakers

    2017-11-01

    Full Text Available ImportanceThere is an ongoing global discussion on whether or not bilateral cochlear implantation should be standard care for bilateral deafness. Contrary to unilateral cochlear implantation, however, little is known about the effect of bilateral cochlear implantation on tinnitus.ObjectiveTo investigate tinnitus outcomes 1 year after bilateral cochlear implantation. Secondarily, to compare tinnitus outcomes between simultaneous and sequential bilateral cochlear implantation and to investigate long-term follow-up (3 years.Study designThis study is a secondary analysis as part of a multicenter randomized controlled trial.MethodsThirty-eight postlingually deafened adults were included in the original trial, in which the presence of tinnitus was not an inclusion criterion. All participants received cochlear implants (CIs because of profound hearing loss. Nineteen participants received bilateral CIs simultaneously and 19 participants received bilateral CIs sequentially with an inter-implant interval of 2 years. The prevalence and severity of tinnitus before and after simultaneous and sequential bilateral cochlear implantation were measured preoperatively and each year after implantation with the Tinnitus Handicap Inventory (THI and Tinnitus Questionnaire (TQ.ResultsThe prevalence of preoperative tinnitus was 42% (16/38. One year after bilateral implantation, there was a median difference of −8 (inter-quartile range (IQR: −28 to 4 in THI score and −9 (IQR: −17 to −9 in TQ score in the participants with preoperative tinnitus. Induction of tinnitus occurred in five participants, all in the simultaneous group, in the year after bilateral implantation. Although the preoperative and also the postoperative median THI and TQ scores were higher in the simultaneous group, the median difference scores were equal in both groups. In the simultaneous group, tinnitus scores fluctuated in the 3 years after implantation. In the sequential group

  4. [Bilateral cochlear implants].

    Science.gov (United States)

    Müller, J

    2017-07-01

    Cochlear implants (CI) are standard for the hearing rehabilitation of severe to profound deafness. Nowadays, if bilaterally indicated, bilateral implantation is usually recommended (in accordance with German guidelines). Bilateral implantation enables better speech discrimination in quiet and in noise, and restores directional and spatial hearing. Children with bilateral CI are able to undergo hearing-based hearing and speech development. Within the scope of their individual possibilities, bilaterally implanted children develop faster than children with unilateral CI and attain, e.g., a larger vocabulary within a certain time interval. Only bilateral implantation allows "binaural hearing," with all the benefits that people with normal hearing profit from, namely: better speech discrimination in quiet and in noise, as well as directional and spatial hearing. Naturally, the developments take time. Binaural CI users benefit from the same effects as normal hearing persons: head shadow effect, squelch effect, and summation and redundancy effects. Sequential CI fitting is not necessarily disadvantageous-both simultaneously and sequentially fitted patients benefit in a similar way. For children, earliest possible fitting and shortest possible interval between the two surgeries seems to positively influence the outcome if bilateral CI are indicated.

  5. A longitudinal study of the bilateral benefit in children with bilateral cochlear implants.

    Science.gov (United States)

    Asp, Filip; Mäki-Torkko, Elina; Karltorp, Eva; Harder, Henrik; Hergils, Leif; Eskilsson, Gunnar; Stenfelt, Stefan

    2015-02-01

    To study the development of the bilateral benefit in children using bilateral cochlear implants by measurements of speech recognition and sound localization. Bilateral and unilateral speech recognition in quiet, in multi-source noise, and horizontal sound localization was measured at three occasions during a two-year period, without controlling for age or implant experience. Longitudinal and cross-sectional analyses were performed. Results were compared to cross-sectional data from children with normal hearing. Seventy-eight children aged 5.1-11.9 years, with a mean bilateral cochlear implant experience of 3.3 years and a mean age of 7.8 years, at inclusion in the study. Thirty children with normal hearing aged 4.8-9.0 years provided normative data. For children with cochlear implants, bilateral and unilateral speech recognition in quiet was comparable whereas a bilateral benefit for speech recognition in noise and sound localization was found at all three test occasions. Absolute performance was lower than in children with normal hearing. Early bilateral implantation facilitated sound localization. A bilateral benefit for speech recognition in noise and sound localization continues to exist over time for children with bilateral cochlear implants, but no relative improvement is found after three years of bilateral cochlear implant experience.

  6. Cochlear implantation in a bilateral Mondini dysplasia.

    Science.gov (United States)

    Turrini, M; Orzan, E; Gabana, M; Genovese, E; Arslan, E; Fisch, U

    1997-01-01

    We report the speech perception progress and programming procedures of a case of congenital profound deafness and bilateral Mondini dysplasia implanted with a Nucleus 20 + 2 cochlear implant at the age of six. Unclear relations between electrodes array and cochlear partition made implant programming difficult and non-standard procedures were set. Cochlear implantation may give excellent rehabilitative results also in cochleae with malformation.

  7. United Kingdom national paediatric bilateral cochlear implant audit: preliminary results.

    Science.gov (United States)

    Cullington, Helen; Bele, Devyanee; Brinton, Julie; Lutman, Mark

    2013-11-01

    Prior to 2009, United Kingdom (UK) public funding was mainly only available for children to receive unilateral cochlear implants. In 2009, the National Institute for Health and Care Excellence published guidance for cochlear implantation following their review. According to these guidelines, all suitable children are eligible to have simultaneous bilateral cochlear implants or a sequential bilateral cochlear implant if they had received the first before the guidelines were published. Fifteen UK cochlear implant centres formed a consortium to carry out a multi-centre audit. The audit involves collecting data from simultaneously and sequentially implanted children at four intervals: before bilateral cochlear implants or before the sequential implant, 1, 2, and 3 years after bilateral implants. The measures include localization, speech recognition in quiet and background noise, speech production, listening, vocabulary, parental perception, quality of life, and surgical data including complications. The audit has now passed the 2-year point, and data have been received on 850 children. This article provides a first view of some data received up until March 2012.

  8. Comparison of outcomes in a case of bilateral cochlear implantation using devices manufactured by two different implant companies (Cochlear Corporation and Med-El).

    Science.gov (United States)

    Withers, S J; Gibson, W P; Greenberg, S L; Bray, M

    2011-05-01

    This paper reports a case of a patient who has had bilateral cochlear implants that have been manufactured by different cochlear implant companies (Cochlear Corporation and Med-El). Comparison of speech perception tests following single implant insertion and bilateral insertion (3 and 12 months). The patient was also interviewed to obtain a subjective opinion on their quality of hearing. The patient reported that their Med-El implant had better sound quality than their Cochlear Corporation implant. The speech perception tests however failed to show any difference. Despite no difference found with the objective tests hearing is very subjective and therefore the patient's opinion on the quality of sound is important. It is only a matter of time before other patients are fitted with bilateral cochlear implants from different companies and this information should be collated to allow comparison between manufacturers.

  9. Effect of unilateral and simultaneous bilateral cochlear implantation on tinnitus : A Prospective Study

    NARCIS (Netherlands)

    van Zon, Alice; Smulders, Yvette E.; Ramakers, Geerte G. J.; Stegeman, Inge; Smit, Adriana L.; Van Zanten, Gijsbert A.; Stokroos, Robert J.; Hendrice, Nadia; Free, Rolien H.; Maat, Bert; Frijns, Johan H. M.; Mylanus, Emmanuel A. M.; Huinck, Wendy J.; Topsakal, Vedat; Tange, Rinze A.; Grolman, Wilko

    Objectives/HypothesisTo determine the effect of cochlear implantation on tinnitus perception in patients with severe bilateral postlingual sensorineural hearing loss and to demonstrate possible differences between unilateral and bilateral cochlear implantation. Study DesignProspective study.

  10. Simultaneous bilateral cochlear implantation in a five-month-old child with Usher syndrome.

    Science.gov (United States)

    Alsanosi, A A

    2015-09-01

    To report a rare case of simultaneous bilateral cochlear implantation in a five-month-old child with Usher syndrome. Case report. A five-month-old boy with Usher syndrome and congenital profound bilateral deafness underwent simultaneous bilateral cochlear implantation. The decision to perform implantation in such a young child was based on his having a supportive family and the desire to foster his audiological development before his vision deteriorated. The subject experienced easily resolvable intra- and post-operative adverse events, and was first fitted with an externally worn audio processor four weeks after implantation. At 14 months of age, his audiological development was age-appropriate. Simultaneous bilateral cochlear implantation is possible, and even advisable, in children as young as five months old when performed by an experienced implantation team.

  11. Simultaneous Bilateral Cochlear Implantation for a 6-Month Child with a History of Meningitis

    Directory of Open Access Journals (Sweden)

    Kh. M. Diab

    2015-01-01

    Full Text Available The article presents the first case of simultaneous bilateral cochlear implantation for a 6-month child with IV degree sensorineural hearing loss after meningocephalitis in Russia. Despite partial ossification of the cochlear basal turns, the early timing of implantation allowed to fully implant active electrodes to both ears. The simultaneous bilateral cochlear implantation in young children, who had meningitis, is a minimally invasive and highly efficient procedure with good long-term results of oral-aural after-care.

  12. AUDITORY REHABILITATION AND BILATERAL COCHLEAR IMPLANT ON CHILD WHITH CEREBRAL PALSY

    Directory of Open Access Journals (Sweden)

    Anacléia Melo da Silva Hilgenberg

    2013-01-01

    Full Text Available OBJECTIVE: To describe the hearing and language improvement in children with cerebral palsy submitted to cochlear implantation bilaterally. METHODS: Prospective, analytical descriptive. Study case and a broad bibliographical analysis in MEDLINE/PUBMED and EMBASE including detailed analysis of the rehabilitation techniques as serial phonoaudiological appointments; Sessions of phonoterapy recorded and criterious analysis of the tests such as IT-MAIS and MacArthur analysis. The teste were applied after Bilateral Cochlear Implantation: 15, 20, 22, 31 e 38 months.RESULTS: The results obtained and bibliographical analysis showed that cochlear implantation in children with cerebral palsy and profound hearing loss is the best option at the moment to perform hearing rehabilitation. The IT-MAIS and MacArthur tests showed a big improvement at 15 and 38 months after use of the cochlear implants. The IT-MAIS test showed 40% score in the beggining and 75% at the end. Mac Arthur test revealed a big evolution at vocabulary comprehension (58 to 342 and linguistic repertory (54 to 289.

  13. Cochlear implantation in patients with bilateral cochlear trauma.

    Science.gov (United States)

    Serin, Gediz Murat; Derinsu, Ufuk; Sari, Murat; Gergin, Ozgül; Ciprut, Ayça; Akdaş, Ferda; Batman, Cağlar

    2010-01-01

    Temporal bone fracture, which involves the otic capsule, can lead to complete loss of auditory and vestibular functions, whereas the patients without fractures may experience profound sensorineural hearing loss due to cochlear concussion. Cochlear implant is indicated in profound sensorineural hearing loss due to cochlear trauma but who still have an intact auditory nerve. This is a retrospective review study. We report 5 cases of postlingually deafened patients caused by cochlear trauma, who underwent cochlear implantation. Preoperative and postoperative hearing performance will be presented. These patients are cochlear implanted after the cochlear trauma in our department between 2001 and 2006. All patients performed very well with their implants, obtained open-set speech understanding. They all became good telephone users after implantation. Their performance in speech understanding was comparable to standard postlingual adult patients implanted. Cochlear implantation is an effective aural rehabilitation in profound sensorineural hearing loss caused by temporal bone trauma. Preoperative temporal bone computed tomography, magnetic resonance imaging, and promontorium stimulation testing are necessary to make decision for the surgery and to determine the side to be implanted. Surgery could be challenging and complicated because of anatomical irregularity. Moreover, fibrosis and partial or total ossification within the cochlea must be expected. Copyright 2010. Published by Elsevier Inc.

  14. Comparison between bilateral cochlear implants and Neurelec Digisonic(®) SP Binaural cochlear implant: speech perception, sound localization and patient self-assessment.

    Science.gov (United States)

    Bonnard, Damien; Lautissier, Sylvie; Bosset-Audoit, Amélie; Coriat, Géraldine; Beraha, Max; Maunoury, Antoine; Martel, Jacques; Darrouzet, Vincent; Bébéar, Jean-Pierre; Dauman, René

    2013-01-01

    An alternative to bilateral cochlear implantation is offered by the Neurelec Digisonic(®) SP Binaural cochlear implant, which allows stimulation of both cochleae within a single device. The purpose of this prospective study was to compare a group of Neurelec Digisonic(®) SP Binaural implant users (denoted BINAURAL group, n = 7) with a group of bilateral adult cochlear implant users (denoted BILATERAL group, n = 6) in terms of speech perception, sound localization, and self-assessment of health status and hearing disability. Speech perception was assessed using word recognition at 60 dB SPL in quiet and in a 'cocktail party' noise delivered through five loudspeakers in the hemi-sound field facing the patient (signal-to-noise ratio = +10 dB). The sound localization task was to determine the source of a sound stimulus among five speakers positioned between -90° and +90° from midline. Change in health status was assessed using the Glasgow Benefit Inventory and hearing disability was evaluated with the Abbreviated Profile of Hearing Aid Benefit. Speech perception was not statistically different between the two groups, even though there was a trend in favor of the BINAURAL group (mean percent word recognition in the BINAURAL and BILATERAL groups: 70 vs. 56.7% in quiet, 55.7 vs. 43.3% in noise). There was also no significant difference with regard to performance in sound localization and self-assessment of health status and hearing disability. On the basis of the BINAURAL group's performance in hearing tasks involving the detection of interaural differences, implantation with the Neurelec Digisonic(®) SP Binaural implant may be considered to restore effective binaural hearing. Based on these first comparative results, this device seems to provide benefits similar to those of traditional bilateral cochlear implantation, with a new approach to stimulate both auditory nerves. Copyright © 2013 S. Karger AG, Basel.

  15. Comparative study between unilateral and bilateral cochlear implantation in children of 1 and 2 years of age.

    Science.gov (United States)

    Escorihuela García, Vicente; Pitarch Ribas, María Ignacia; Llópez Carratalá, Ignacio; Latorre Monteagudo, Emilia; Morant Ventura, Antonio; Marco Algarra, Jaime

    2016-01-01

    The studies that have evaluated the effectiveness of bilateral cochlear implantation in children suggest an improvement in hearing about sound localization and speech discrimination. In this paper we show the differences in audio-linguistic achievements with early bilateral cochlear implantation versus unilateral, and differences between simultaneous and sequential bilateral implantation. We present 88 children with bilateral profound sensorineural hearing loss, treated with bilateral cochlear implantation in 32 cases and unilateral in 56 cases, during the first 12 months (27 children) of life and between 12 and 24 months (61 children). We conducted a statistical comparison of both groups in the audiometry, IT-Mais, Nottingham, LittlEars scales and verbal tests. No significant differences in hearing thresholds and questionnaires between unilateral and bilateral implantation were detected in either the first or second year. Verbal tests do show statistically significant differences: children with bilateral cochlear implant obtain 100% recognition of disyllabic and phrases within 2-3 years after implantation whilst children with one implant do not obtain those results at 5 years after surgery. No differences between simultaneous and sequential bilateral implantation were detected. We emphasize the importance of ensuring good early audiological screening, to carry out an early and bilateral cochlear implantation with the consequent development of audio-language skills similar to normal hearing children. Copyright © 2015 Elsevier España, S.L.U. y Sociedad Española de Otorrinolaringología y Cirugía de Cabeza y Cuello. All rights reserved.

  16. Bilateral Cochlear Implants: Maximizing Expected Outcomes.

    Science.gov (United States)

    Wallis, Kate E; Blum, Nathan J; Waryasz, Stephanie A; Augustyn, Marilyn

    Sonia is a 4 years 1 month-year-old girl with Waardenburg syndrome and bilateral sensorineural hearing loss who had bilateral cochlear implants at 2 years 7 months years of age. She is referred to Developmental-Behavioral Pediatrics by her speech/language pathologist because of concerns that her language skills are not progressing as expected after the cochlear implant. At the time of the implant, she communicated using approximately 20 signs and 1 spoken word (mama). At the time of the evaluation (18 months after the implant) she had approximately 70 spoken words (English and Spanish) and innumerable signs that she used to communicate. She could follow 1-step directions in English but had more difficulty after 2-step directions.Sonia was born in Puerto Rico at 40 weeks gestation after an uncomplicated pregnancy. She failed her newborn hearing test and was given hearing aids that did not seem to help.At age 2 years, Sonia, her mother, and younger sister moved to the United States where she was diagnosed with bilateral severe-to-profound hearing loss. Genetic testing led to a diagnosis of Waardenburg syndrome (group of genetic conditions that can cause hearing loss and changes in coloring [pigmentation] of the hair, skin, and eyes). She received bilateral cochlear implants 6 months later.Sonia's mother is primarily Spanish-speaking and mostly communicates with her in Spanish or with gestures but has recently begun to learn American Sign Language (ASL). In a preschool program at a specialized school for the deaf, Sonia is learning both English and ASL. Sonia seems to prefer to use ASL to communicate.Sonia receives speech and language therapy (SLT) 3 times per week (90 minutes total) individually in school and once per week within a group. She is also receiving outpatient SLT once per week. Therapy sessions are completed in English, with the aid of an ASL interpreter. Sonia's language scores remain low, with her receptive skills in the first percentile, and her

  17. Bilateral cochlear implants in infants: a new approach--Nucleus Hybrid S12 project.

    Science.gov (United States)

    Gantz, Bruce J; Dunn, Camille C; Walker, Elizabeth A; Kenworthy, Maura; Van Voorst, Tanya; Tomblin, Bruce; Turner, Chris

    2010-10-01

    The purpose of this feasibility study was to evaluate whether the use of a shorter-length cochlear implant (10 mm) on one ear and a standard electrode (24 mm) on the contralateral ear is a viable bilateral option for children with profound bilateral sensorineural hearing loss. A secondary purpose of this study was to determine whether the ear with the shorter-length electrode performs similarly to the standard-length electrode. Our goal was to provide an option of electrical stimulation that theoretically might preserve the structures of the scala media and organ of Corti. The study is being conducted as a repeated-measure, single-subject experiment. University of Iowa-Department of Otolaryngology. Eight pediatric patients with profound bilateral sensorineural hearing loss between the ages of 12 and 24 months. Nucleus Hybrid S12 10-mm electrode and a Nucleus Freedom implant in the contralateral ear. The Infant-Toddler Meaningful Auditory Integration Scale (IT-MAIS) parent questionnaire, Early Speech Perception, Glendonald Auditory Screening Procedure word test, and Children's Vowel tests will be used to evaluate speech perception and the Minnesota Child Development Inventory and Preschool Language Scales 3 test will be used to evaluate language growth. Preliminary results for 8 children have been collected before and after the operation using the IT-MAIS. All 3 children showed incremental improvements in their IT-MAIS scores overtime. Early Speech Perception, Glendonald Auditory Screening Procedure word test, and Children's Vowel word perception results indicated no difference between the individual ears for the 2 children tested. Performance compared with age-matched children implanted with standard bilateral cochlear implants showed similar results to the children implanted with Nucleus Hybrid S12 10-mm electrode and a Nucleus Freedom implant in contralateral ears. The use of a shorter-length cochlear implant on one ear and a standard-length electrode on the

  18. Bilateral cochlear implantation: current concepts, indications, and results.

    Science.gov (United States)

    Basura, Gregory J; Eapen, Rose; Buchman, Craig A

    2009-12-01

    The optimal treatment for bilateral hearing loss continues to evolve as cochlear implant (CI) and hearing aid technologies advance, as does our understanding of the central auditory system. Ongoing discussions continue on the validity and feasibility of bilateral CI in terms of performance, justification of need, medical/surgical safety concerns, and economics. The purpose of this review article is to provide an update on the advantages and disadvantages of bilateral CI and to provide a discussion on timing (simultaneous vs. sequential), technology (bimodal vs. binaural) and feasibility. Binaural advantages are found in both adult and pediatric bilateral CI recipients, the greatest being the head shadow effect and improvements in localization and loudness summation. This theoretically offers an advantage over their unilateral implanted counterparts in terms of improved sound localization and enhanced speech perception under noisy conditions. Most investigators agree that bilateral stimulation during critical periods of development is paramount for optimizing auditory functioning in children. Currently, bilateral CI is widely accepted as a safe and effective means of bilateral auditory stimulation.

  19. Bilateral Cochlear Implants in Infants: A New Approach—Nucleus Hybrid S12 Project

    Science.gov (United States)

    Gantz, Bruce J.; Dunn, Camille C.; Walker, Elizabeth A.; Kenworthy, Maura; Van Voorst, Tanya; Tomblin, Bruce; Turner, Chris

    2010-01-01

    Objective The purpose of this feasibility study was to evaluate whether the use of a shorter-length cochlear implant (10 mm) on one ear and a standard electrode (24 mm) on the contralateral ear is a viable bilateral option for children with profound bilateral sensorineural hearing loss. A secondary purpose of this study was to determine whether the ear with the shorter-length electrode performs similarly to the standard-length electrode. Our goal was to provide an option of electrical stimulation that theoretically might preserve the structures of the scala media and organ of Corti. Study Design The study is being conducted as a repeated-measure, single-subject experiment. Setting University of Iowa—Department of Otolaryngology. Patients Eight pediatric patients with profound bilateral sensorineural hearing loss between the ages of 12 and 24 months. Interventions Nucleus Hybrid S12 10-mm electrode and a Nucleus Freedom implant in the contralateral ear. Main Outcome Measures The Infant-Toddler Meaningful Auditory Integration Scale (IT-MAIS) parent questionnaire, Early Speech Perception, Glendonald Auditory Screening Procedure word test, and Children’s Vowel tests will be used to evaluate speech perception and the Minnesota Child Development Inventory and Preschool Language Scales 3 test will be used to evaluate language growth. Results Preliminary results for 8 children have been collected before and after the operation using the IT-MAIS. All 3 children showed incremental improvements in their IT-MAIS scores overtime. Early Speech Perception, Glendonald Auditory Screening Procedure word test, and Children’s Vowel word perception results indicated no difference between the individual ears for the 2 children tested. Performance compared with age-matched children implanted with standard bilateral cochlear implants showed similar results to the children implanted with Nucleus Hybrid S12 10-mm electrode and a Nucleus Freedom implant in contralateral ears

  20. Analysis of electrically evoked compound action potential of the auditory nerve in children with bilateral cochlear implants.

    Science.gov (United States)

    Caldas, Fernanda Ferreira; Cardoso, Carolina Costa; Barreto, Monique Antunes de Souza Chelminski; Teixeira, Marina Santos; Hilgenberg, Anacléia Melo da Silva; Serra, Lucieny Silva Martins; Bahmad Junior, Fayez

    2016-01-01

    The cochlear implant device has the capacity to measure the electrically evoked compound action potential of the auditory nerve. The neural response telemetry is used in order to measure the electrically evoked compound action potential of the auditory nerve. To analyze the electrically evoked compound action potential, through the neural response telemetry, in children with bilateral cochlear implants. This is an analytical, prospective, longitudinal, historical cohort study. Six children, aged 1-4 years, with bilateral cochlear implant were assessed at five different intervals during their first year of cochlear implant use. There were significant differences in follow-up time (p=0.0082) and electrode position (p=0.0019) in the T-NRT measure. There was a significant difference in the interaction between time of follow-up and electrode position (p=0.0143) when measuring the N1-P1 wave amplitude between the three electrodes at each time of follow-up. The electrically evoked compound action potential measurement using neural response telemetry in children with bilateral cochlear implants during the first year of follow-up was effective in demonstrating the synchronized bilateral development of the peripheral auditory pathways in the studied population. Copyright © 2015 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  1. Binaural fusion and listening effort in children who use bilateral cochlear implants: a psychoacoustic and pupillometric study.

    Science.gov (United States)

    Steel, Morrison M; Papsin, Blake C; Gordon, Karen A

    2015-01-01

    Bilateral cochlear implants aim to provide hearing to both ears for children who are deaf and promote binaural/spatial hearing. Benefits are limited by mismatched devices and unilaterally-driven development which could compromise the normal integration of left and right ear input. We thus asked whether children hear a fused image (ie. 1 vs 2 sounds) from their bilateral implants and if this "binaural fusion" reduces listening effort. Binaural fusion was assessed by asking 25 deaf children with cochlear implants and 24 peers with normal hearing whether they heard one or two sounds when listening to bilaterally presented acoustic click-trains/electric pulses (250 Hz trains of 36 ms presented at 1 Hz). Reaction times and pupillary changes were recorded simultaneously to measure listening effort. Bilaterally implanted children heard one image of bilateral input less frequently than normal hearing peers, particularly when intensity levels on each side were balanced. Binaural fusion declined as brainstem asymmetries increased and age at implantation decreased. Children implanted later had access to acoustic input prior to implantation due to progressive deterioration of hearing. Increases in both pupil diameter and reaction time occurred as perception of binaural fusion decreased. Results indicate that, without binaural level cues, children have difficulty fusing input from their bilateral implants to perceive one sound which costs them increased listening effort. Brainstem asymmetries exacerbate this issue. By contrast, later implantation, reflecting longer access to bilateral acoustic hearing, may have supported development of auditory pathways underlying binaural fusion. Improved integration of bilateral cochlear implant signals for children is required to improve their binaural hearing.

  2. Different Perception of Musical Stimuli in Patients with Monolateral and Bilateral Cochlear Implants

    Science.gov (United States)

    Maglione, Anton Giulio; Leone, Carlo Antonio; Grassia, Rosa; Mosca, Franco; Colosimo, Alfredo; Malerba, Paolo

    2014-01-01

    The aim of the present study is to measure the perceived pleasantness during the observation of a musical video clip in a group of cochlear implanted adult patients when compared to a group of normal hearing subjects. This comparison was performed by using the imbalance of the EEG power spectra in alpha band over frontal areas as a metric for the perceived pleasantness. Subjects were asked to watch a musical video clip in three different experimental conditions: with the original audio included (Norm), with a distorted version of the audio (Dist), and without the audio (Mute). The frontal EEG imbalance between the estimated power spectra for the left and right prefrontal areas has been calculated to investigate the differences among the two populations. Results suggested that the perceived pleasantness of the musical video clip in the normal hearing population and in the bilateral cochlear implanted populations has similar range of variation across the different stimulations (Norm, Dist, and Mute), when compared to the range of variation of video clip's pleasantness for the monolateral cochlear implanted population. A similarity exists in the trends of the perceived pleasantness across the different experimental conditions in the mono- and bilaterally cochlear implanted patients. PMID:25180046

  3. Sequential bilateral cochlear implantation improves working performance, quality of life, and quality of hearing.

    Science.gov (United States)

    Härkönen, Kati; Kivekäs, Ilkka; Rautiainen, Markus; Kotti, Voitto; Sivonen, Ville; Vasama, Juha-Pekka

    2015-05-01

    This prospective study shows that working performance, quality of life (QoL), and quality of hearing (QoH) are better with two compared with a single cochlear implant (CI). The impact of the second CI on the patient's QoL is as significant as the impact of the first CI. To evaluate the benefits of sequential bilateral cochlear implantation in working, QoL, and QoH. We studied working performance, work-related stress, QoL, and QoH with specific questionnaires in 15 patients with unilateral CI scheduled for sequential CI of another ear. Sound localization performance and speech perception in noise were measured with specific tests. All questionnaires and tests were performed before the second CI surgery and 6 and 12 months after its activation. Bilateral CIs increased patients' working performance and their work-related stress and fatigue decreased. Communication with co-workers was easier and patients were more active in their working environment. Sequential bilateral cochlear implantation improved QoL, QoH, sound localization, and speech perception in noise statistically significantly.

  4. Binaural Fusion and Listening Effort in Children Who Use Bilateral Cochlear Implants: A Psychoacoustic and Pupillometric Study

    Science.gov (United States)

    Steel, Morrison M.; Papsin, Blake C.; Gordon, Karen A.

    2015-01-01

    Bilateral cochlear implants aim to provide hearing to both ears for children who are deaf and promote binaural/spatial hearing. Benefits are limited by mismatched devices and unilaterally-driven development which could compromise the normal integration of left and right ear input. We thus asked whether children hear a fused image (ie. 1 vs 2 sounds) from their bilateral implants and if this “binaural fusion” reduces listening effort. Binaural fusion was assessed by asking 25 deaf children with cochlear implants and 24 peers with normal hearing whether they heard one or two sounds when listening to bilaterally presented acoustic click-trains/electric pulses (250 Hz trains of 36 ms presented at 1 Hz). Reaction times and pupillary changes were recorded simultaneously to measure listening effort. Bilaterally implanted children heard one image of bilateral input less frequently than normal hearing peers, particularly when intensity levels on each side were balanced. Binaural fusion declined as brainstem asymmetries increased and age at implantation decreased. Children implanted later had access to acoustic input prior to implantation due to progressive deterioration of hearing. Increases in both pupil diameter and reaction time occurred as perception of binaural fusion decreased. Results indicate that, without binaural level cues, children have difficulty fusing input from their bilateral implants to perceive one sound which costs them increased listening effort. Brainstem asymmetries exacerbate this issue. By contrast, later implantation, reflecting longer access to bilateral acoustic hearing, may have supported development of auditory pathways underlying binaural fusion. Improved integration of bilateral cochlear implant signals for children is required to improve their binaural hearing. PMID:25668423

  5. Binaural fusion and listening effort in children who use bilateral cochlear implants: a psychoacoustic and pupillometric study.

    Directory of Open Access Journals (Sweden)

    Morrison M Steel

    Full Text Available Bilateral cochlear implants aim to provide hearing to both ears for children who are deaf and promote binaural/spatial hearing. Benefits are limited by mismatched devices and unilaterally-driven development which could compromise the normal integration of left and right ear input. We thus asked whether children hear a fused image (ie. 1 vs 2 sounds from their bilateral implants and if this "binaural fusion" reduces listening effort. Binaural fusion was assessed by asking 25 deaf children with cochlear implants and 24 peers with normal hearing whether they heard one or two sounds when listening to bilaterally presented acoustic click-trains/electric pulses (250 Hz trains of 36 ms presented at 1 Hz. Reaction times and pupillary changes were recorded simultaneously to measure listening effort. Bilaterally implanted children heard one image of bilateral input less frequently than normal hearing peers, particularly when intensity levels on each side were balanced. Binaural fusion declined as brainstem asymmetries increased and age at implantation decreased. Children implanted later had access to acoustic input prior to implantation due to progressive deterioration of hearing. Increases in both pupil diameter and reaction time occurred as perception of binaural fusion decreased. Results indicate that, without binaural level cues, children have difficulty fusing input from their bilateral implants to perceive one sound which costs them increased listening effort. Brainstem asymmetries exacerbate this issue. By contrast, later implantation, reflecting longer access to bilateral acoustic hearing, may have supported development of auditory pathways underlying binaural fusion. Improved integration of bilateral cochlear implant signals for children is required to improve their binaural hearing.

  6. Early vocabulary development in children with bilateral cochlear implants.

    Science.gov (United States)

    Välimaa, Taina; Kunnari, Sari; Laukkanen-Nevala, Päivi; Lonka, Eila

    2018-01-01

    Children with unilateral cochlear implants (CIs) may have delayed vocabulary development for an extended period after implantation. Bilateral cochlear implantation is reported to be associated with improved sound localization and enhanced speech perception in noise. This study proposed that bilateral implantation might also promote early vocabulary development. Knowledge regarding vocabulary growth and composition in children with bilateral CIs and factors associated with it may lead to improvements in the content of early speech and language intervention and family counselling. To analyse the growth of early vocabulary and its composition during the first year after CI activation and to investigate factors associated with vocabulary growth. The participants were 20 children with bilateral CIs (12 boys; eight girls; mean age at CI activation = 12.9 months). Vocabulary size was assessed with the Finnish version of the MacArthur Communicative Development Inventories (CDI) Infant Form and compared with normative data. Vocabulary composition was analysed in relation to vocabulary size. Growth curve modelling was implemented using a linear mixed model to analyse the effects of the following variables on early vocabulary growth: time, gender, maternal education, residual hearing with hearing aids, age at first hearing aid fitting and age at CI activation. Despite clear vocabulary growth over time, children with bilateral CIs lagged behind their age norms in receptive vocabulary during the first 12 months after CI activation. In expressive vocabulary, 35% of the children were able to catch up with their age norms, but 55% of the children lagged behind them. In receptive and expressive vocabularies of 1-20 words, analysis of different semantic categories indicated that social terms constituted the highest proportion. Nouns constituted the highest proportion in vocabularies of 101-400 words. The proportion of verbs remained below 20% and the proportion of function words and

  7. Cochlear implant revision surgeries in children.

    Science.gov (United States)

    Amaral, Maria Stella Arantes do; Reis, Ana Cláudia Mirândola B; Massuda, Eduardo T; Hyppolito, Miguel Angelo

    2018-02-16

    The surgery during which the cochlear implant internal device is implanted is not entirely free of risks and may produce problems that will require revision surgeries. To verify the indications for cochlear implantation revision surgery for the cochlear implant internal device, its effectiveness and its correlation with certain variables related to language and hearing. A retrospective study of patients under 18 years submitted to cochlear implant Surgery from 2004 to 2015 in a public hospital in Brazil. Data collected were: age at the time of implantation, gender, etiology of the hearing loss, audiological and oral language characteristics of each patient before and after Cochlear Implant surgery and any need for surgical revision and the reason for it. Two hundred and sixty-five surgeries were performed in 236 patients. Eight patients received a bilateral cochlear implant and 10 patients required revision surgery. Thirty-two surgeries were necessary for these 10 children (1 bilateral cochlear implant), of which 21 were revision surgeries. In 2 children, cochlear implant removal was necessary, without reimplantation, one with cochlear malformation due to incomplete partition type I and another due to trauma. With respect to the cause for revision surgery, of the 8 children who were successfully reimplanted, four had cochlear calcification following meningitis, one followed trauma, one exhibited a facial nerve malformation, one experienced a failure of the cochlear implant internal device and one revision surgery was necessary because the electrode was twisted. The incidence of the cochlear implant revision surgery was 4.23%. The period following the revision surgeries revealed an improvement in the subject's hearing and language performance, indicating that these surgeries are valid in most cases. Copyright © 2018 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  8. Hybrid cochlear implantation: quality of life, quality of hearing, and working performance compared to patients with conventional unilateral or bilateral cochlear implantation.

    Science.gov (United States)

    Härkönen, Kati; Kivekäs, Ilkka; Kotti, Voitto; Sivonen, Ville; Vasama, Juha-Pekka

    2017-10-01

    The objective of the present study is to evaluate the effect of hybrid cochlear implantation (hCI) on quality of life (QoL), quality of hearing (QoH), and working performance in adult patients, and to compare the long-term results of patients with hCI to those of patients with conventional unilateral cochlear implantation (CI), bilateral CI, and single-sided deafness (SSD) with CI. Sound localization accuracy and speech-in-noise test were also compared between these groups. Eight patients with high-frequency sensorineural hearing loss of unknown etiology were selected in the study. Patients with hCI had better long-term speech perception in noise than uni- or bilateral CI patients, but the difference was not statistically significant. The sound localization accuracy was equal in the hCI, bilateral CI, and SSD patients. QoH was statistically significantly better in bilateral CI patients than in the others. In hCI patients, residual hearing was preserved in all patients after the surgery. During the 3.6-year follow-up, the mean hearing threshold at 125-500 Hz decreased on average by 15 dB HL in the implanted ear. QoL and working performance improved significantly in all CI patients. Hearing outcomes with hCI are comparable to the results of bilateral CI or CI with SSD, but hearing in noise and sound localization are statistically significantly better than with unilateral CI. Interestingly, the impact of CI on QoL, QoH, and working performance was similar in all groups.

  9. AUDITORY REHABILITATION AND BILATERAL COCHLEAR IMPLANT ON CHILD WHITH CEREBRAL PALSY

    OpenAIRE

    Anacléia Melo da Silva Hilgenberg; Fernanda Ferreira Caldas; Tatiana Mendes de Melo; Fayez Bahmad Jr.

    2013-01-01

    OBJECTIVE: To describe the hearing and language improvement in children with cerebral palsy submitted to cochlear implantation bilaterally. METHODS: Prospective, analytical descriptive. Study case and a broad bibliographical analysis in MEDLINE/PUBMED and EMBASE including detailed analysis of the rehabilitation techniques as serial phonoaudiological appointments; Sessions of phonoterapy recorded and criterious analysis of the tests such as IT-MAIS and MacArthur analysis. The teste were applie...

  10. [Quality of life and vertigo after bilateral cochlear implantation : Questionnaires as tools for quality assurance].

    Science.gov (United States)

    Rader, T; Haerterich, M; Ernst, B P; Stöver, T; Strieth, S

    2018-03-01

    Persistent dizziness symptoms after cochlear implantation have an impact on quality of life. In this study, the effects of bilateral cochlear implants (CI) on quality of life as well as on subjective dizziness complaints are analyzed using questionnaires, some of which have never been applied before in these patient collectives. In this article, questionnaires for the assessment of dizziness symptoms and quality of life are introduced in order to realize quality assurance. A total of 32 patients with bilateral CI were questioned regarding dizziness symptoms and quality of life. The Nijmegen Cochlear Implant Questionnaire (NCIQ) was used. In the case of reported regular dizziness, the Vertigo Handicap Questionnaire (VHQ) and the Vertigo Symptom Scale (VSS) were also assessed. Persistent dizziness symptoms were shown in 8 of 32 patients. Quality of life was measured with the NCIQ and was improved significantly (p < 0.001) by 23.7% after the second CI. The dizziness symptoms changed slightly (VHQ -11.2%; VSS +16.4%) after the second implantation. The results show that the questionnaires are valid instruments for documenting quality of life and dizziness symptoms for quality assurance. These questionnaires may be applied as a complement or an alternative to device-based measurements of peripheral vestibular dysfunction.

  11. Comparison of bimodal and bilateral cochlear implant users on speech recognition with competing talker, music perception, affective prosody discrimination, and talker identification.

    Science.gov (United States)

    Cullington, Helen E; Zeng, Fan-Gang

    2011-02-01

    Despite excellent performance in speech recognition in quiet, most cochlear implant users have great difficulty with speech recognition in noise, music perception, identifying tone of voice, and discriminating different talkers. This may be partly due to the pitch coding in cochlear implant speech processing. Most current speech processing strategies use only the envelope information; the temporal fine structure is discarded. One way to improve electric pitch perception is to use residual acoustic hearing via a hearing aid on the nonimplanted ear (bimodal hearing). This study aimed to test the hypothesis that bimodal users would perform better than bilateral cochlear implant users on tasks requiring good pitch perception. Four pitch-related tasks were used. 1. Hearing in Noise Test (HINT) sentences spoken by a male talker with a competing female, male, or child talker. 2. Montreal Battery of Evaluation of Amusia. This is a music test with six subtests examining pitch, rhythm and timing perception, and musical memory. 3. Aprosodia Battery. This has five subtests evaluating aspects of affective prosody and recognition of sarcasm. 4. Talker identification using vowels spoken by 10 different talkers (three men, three women, two boys, and two girls). Bilateral cochlear implant users were chosen as the comparison group. Thirteen bimodal and 13 bilateral adult cochlear implant users were recruited; all had good speech perception in quiet. There were no significant differences between the mean scores of the bimodal and bilateral groups on any of the tests, although the bimodal group did perform better than the bilateral group on almost all tests. Performance on the different pitch-related tasks was not correlated, meaning that if a subject performed one task well they would not necessarily perform well on another. The correlation between the bimodal users' hearing threshold levels in the aided ear and their performance on these tasks was weak. Although the bimodal cochlear

  12. The Relationship between Binaural Benefit and Difference in Unilateral Speech Recognition Performance for Bilateral Cochlear Implant Users

    Science.gov (United States)

    Yoon, Yang-soo; Li, Yongxin; Kang, Hou-Yong; Fu, Qian-Jie

    2011-01-01

    Objective The full benefit of bilateral cochlear implants may depend on the unilateral performance with each device, the speech materials, processing ability of the user, and/or the listening environment. In this study, bilateral and unilateral speech performances were evaluated in terms of recognition of phonemes and sentences presented in quiet or in noise. Design Speech recognition was measured for unilateral left, unilateral right, and bilateral listening conditions; speech and noise were presented at 0° azimuth. The “binaural benefit” was defined as the difference between bilateral performance and unilateral performance with the better ear. Study Sample 9 adults with bilateral cochlear implants participated. Results On average, results showed a greater binaural benefit in noise than in quiet for all speech tests. More importantly, the binaural benefit was greater when unilateral performance was similar across ears. As the difference in unilateral performance between ears increased, the binaural advantage decreased; this functional relationship was observed across the different speech materials and noise levels even though there was substantial intra- and inter-subject variability. Conclusions The results indicate that subjects who show symmetry in speech recognition performance between implanted ears in general show a large binaural benefit. PMID:21696329

  13. New Criteria of Indication and Selection of Patients to Cochlear Implant

    Directory of Open Access Journals (Sweden)

    André L. L. Sampaio

    2011-01-01

    Full Text Available Numerous changes continue to occur in cochlear implant candidacy. In general, these have been accompanied by concomitant and satisfactory changes in surgical techniques. Together, this has advanced the utility and safety of cochlear implantation. Most devices are now approved for use in patients with severe to profound unilateral hearing loss rather then the prior requirement of a bilateral profound loss. Furthermore, studies have begun utilizing short electrode arrays for shallow insertion in patients with considerable low-frequency residual hearing. This technique will allow the recipient to continue to use acoustically amplified hearing for the low frequencies simultaneously with a cochlear implant for the high frequencies. The advances in design of, and indications for, cochlear implants have been matched by improvements in surgical techniques and decrease in complications. The resulting improvements in safety and efficacy have further encouraged the use of these devices. This paper will review the new concepts in the candidacy of cochlear implant. Medline data base was used to search articles dealing with the following topics: cochlear implant in younger children, cochlear implant and hearing preservation, cochlear implant for unilateral deafness and tinnitus, genetic hearing loss and cochlear implant, bilateral cochlear implant, neuropathy and cochlear implant and neural plasticity, and the selection of patients for cochlear implant.

  14. Binaural Speech Understanding With Bilateral Cochlear Implants in Reverberation.

    Science.gov (United States)

    Kokkinakis, Kostas

    2018-03-08

    The purpose of this study was to investigate whether bilateral cochlear implant (CI) listeners who are fitted with clinical processors are able to benefit from binaural advantages under reverberant conditions. Another aim of this contribution was to determine whether the magnitude of each binaural advantage observed inside a highly reverberant environment differs significantly from the magnitude measured in a near-anechoic environment. Ten adults with postlingual deafness who are bilateral CI users fitted with either Nucleus 5 or Nucleus 6 clinical sound processors (Cochlear Corporation) participated in this study. Speech reception thresholds were measured in sound field and 2 different reverberation conditions (0.06 and 0.6 s) as a function of the listening condition (left, right, both) and the noise spatial location (left, front, right). The presence of the binaural effects of head-shadow, squelch, summation, and spatial release from masking in the 2 different reverberation conditions tested was determined using nonparametric statistical analysis. In the bilateral population tested, when the ambient reverberation time was equal to 0.6 s, results indicated strong positive effects of head-shadow and a weaker spatial release from masking advantage, whereas binaural squelch and summation contributed no statistically significant benefit to bilateral performance under this acoustic condition. These findings are consistent with those of previous studies, which have demonstrated that head-shadow yields the most pronounced advantage in noise. The finding that spatial release from masking produced little to almost no benefit in bilateral listeners is consistent with the hypothesis that additive reverberation degrades spatial cues and negatively affects binaural performance. The magnitude of 4 different binaural advantages was measured on the same group of bilateral CI subjects fitted with clinical processors in 2 different reverberation conditions. The results of this work

  15. The effects of early auditory-based intervention on adult bilateral cochlear implant outcomes.

    Science.gov (United States)

    Lim, Stacey R

    2017-09-01

    The goal of this exploratory study was to determine the types of improvement that sequentially implanted auditory-verbal and auditory-oral adults with prelingual and childhood hearing loss received in bilateral listening conditions, compared to their best unilateral listening condition. Five auditory-verbal adults and five auditory-oral adults were recruited for this study. Participants were seated in the center of a 6-loudspeaker array. BKB-SIN sentences were presented from 0° azimuth, while multi-talker babble was presented from various loudspeakers. BKB-SIN scores in bilateral and the best unilateral listening conditions were compared to determine the amount of improvement gained. As a group, the participants had improved speech understanding scores in the bilateral listening condition. Although not statistically significant, the auditory-verbal group tended to have greater speech understanding with greater levels of competing background noise, compared to the auditory-oral participants. Bilateral cochlear implantation provides individuals with prelingual and childhood hearing loss with improved speech understanding in noise. A higher emphasis on auditory development during the critical language development years may add to increased speech understanding in adulthood. However, other demographic factors such as age or device characteristics must also be considered. Although both auditory-verbal and auditory-oral approaches emphasize spoken language development, they emphasize auditory development to different degrees. This may affect cochlear implant (CI) outcomes. Further consideration should be made in future auditory research to determine whether these differences contribute to performance outcomes. Additional investigation with a larger participant pool, controlled for effects of age and CI devices and processing strategies, would be necessary to determine whether language learning approaches are associated with different levels of speech understanding

  16. Experience Changes How Emotion in Music Is Judged: Evidence from Children Listening with Bilateral Cochlear Implants, Bimodal Devices, and Normal Hearing.

    Directory of Open Access Journals (Sweden)

    Sara Giannantonio

    Full Text Available Children using unilateral cochlear implants abnormally rely on tempo rather than mode cues to distinguish whether a musical piece is happy or sad. This led us to question how this judgment is affected by the type of experience in early auditory development. We hypothesized that judgments of the emotional content of music would vary by the type and duration of access to sound in early life due to deafness, altered perception of musical cues through new ways of using auditory prostheses bilaterally, and formal music training during childhood. Seventy-five participants completed the Montreal Emotion Identification Test. Thirty-three had normal hearing (aged 6.6 to 40.0 years and 42 children had hearing loss and used bilateral auditory prostheses (31 bilaterally implanted and 11 unilaterally implanted with contralateral hearing aid use. Reaction time and accuracy were measured. Accurate judgment of emotion in music was achieved across ages and musical experience. Musical training accentuated the reliance on mode cues which developed with age in the normal hearing group. Degrading pitch cues through cochlear implant-mediated hearing induced greater reliance on tempo cues, but mode cues grew in salience when at least partial acoustic information was available through some residual hearing in the contralateral ear. Finally, when pitch cues were experimentally distorted to represent cochlear implant hearing, individuals with normal hearing (including those with musical training switched to an abnormal dependence on tempo cues. The data indicate that, in a western culture, access to acoustic hearing in early life promotes a preference for mode rather than tempo cues which is enhanced by musical training. The challenge to these preferred strategies during cochlear implant hearing (simulated and real, regardless of musical training, suggests that access to pitch cues for children with hearing loss must be improved by preservation of residual hearing and

  17. Experience Changes How Emotion in Music Is Judged: Evidence from Children Listening with Bilateral Cochlear Implants, Bimodal Devices, and Normal Hearing

    Science.gov (United States)

    Papsin, Blake C.; Paludetti, Gaetano; Gordon, Karen A.

    2015-01-01

    Children using unilateral cochlear implants abnormally rely on tempo rather than mode cues to distinguish whether a musical piece is happy or sad. This led us to question how this judgment is affected by the type of experience in early auditory development. We hypothesized that judgments of the emotional content of music would vary by the type and duration of access to sound in early life due to deafness, altered perception of musical cues through new ways of using auditory prostheses bilaterally, and formal music training during childhood. Seventy-five participants completed the Montreal Emotion Identification Test. Thirty-three had normal hearing (aged 6.6 to 40.0 years) and 42 children had hearing loss and used bilateral auditory prostheses (31 bilaterally implanted and 11 unilaterally implanted with contralateral hearing aid use). Reaction time and accuracy were measured. Accurate judgment of emotion in music was achieved across ages and musical experience. Musical training accentuated the reliance on mode cues which developed with age in the normal hearing group. Degrading pitch cues through cochlear implant-mediated hearing induced greater reliance on tempo cues, but mode cues grew in salience when at least partial acoustic information was available through some residual hearing in the contralateral ear. Finally, when pitch cues were experimentally distorted to represent cochlear implant hearing, individuals with normal hearing (including those with musical training) switched to an abnormal dependence on tempo cues. The data indicate that, in a western culture, access to acoustic hearing in early life promotes a preference for mode rather than tempo cues which is enhanced by musical training. The challenge to these preferred strategies during cochlear implant hearing (simulated and real), regardless of musical training, suggests that access to pitch cues for children with hearing loss must be improved by preservation of residual hearing and improvements in

  18. The cochlear implant as a tinnitus treatment.

    Science.gov (United States)

    Vallés-Varela, Héctor; Royo-López, Juan; Carmen-Sampériz, Luis; Sebastián-Cortés, José M; Alfonso-Collado, Ignacio

    2013-01-01

    Tinnitus is a symptom of high prevalence in patients with cochlear pathology. We studied the evolution of tinnitus in patients undergoing unilateral cochlear implantation for treatment of profound hearing loss. This was a longitudinal, retrospective study of patients that underwent unilateral cochlear implantation and who had bilateral tinnitus. Tinnitus was assessed quantitatively and qualitatively before surgery and at 6 and 12 months after surgery. We evaluated 20 patients that underwent unilateral cochlear implantation with a Nucleus(®) CI24RE Contour Advance™ electrode device. During the periods in which the device was in operation, improvement or disappearance of tinnitus was evidenced in the ipsilateral ear in 65% of patients, and in the contralateral ear, in 50%. In periods in which the device was disconnected, improvement or disappearance of tinnitus was found in the ipsilateral ear in 50% of patients, and in the ear contralateral to the implant in 45% of the patients. In 10% of the patients, a new tinnitus appeared in the ipsilateral ear. The patients with profound hearing loss and bilateral tinnitus treated with unilateral cochlear implantation improved in a high percentage of cases, in the ipsilateral ear and in the contralateral ear. Copyright © 2012 Elsevier España, S.L. All rights reserved.

  19. The effect of cochlear implantation on tinnitus in patients with bilateral hearing loss : A systematic review

    NARCIS (Netherlands)

    Ramakers, Geerte G J; van Zon, Alice; Stegeman, Inge; Grolman, Wilko

    2015-01-01

    OBJECTIVES: To present an overview of the effect of cochlear implantation on tinnitus in adults with bilateral sensorineural hearing loss. DATA SOURCES: PubMed, Cochrane Library, CINAHL, and Embase databases were searched for articles from database inception up to January 13, 2015. METHODS: A

  20. Rapid assessment of bilateral cochlear implantation for children in Kazakhstan.

    Science.gov (United States)

    Kosherbayeva, Lyazzat; Hailey, David; Kozhageldiyeva, Laura

    2014-10-01

    The aim of this study was to evaluate the effectiveness of bilateral cochlear implantation (CI) compared with unilateral CI for deaf children in the context of the Republic of Kazakhstan health system. Methods. A literature search was conducted, using the PubMed, Cochrane, and Embase data bases for studies that compared the effectiveness of bilateral and unilateral CI in children. The search included English language, publications from 2002-2012. Two reviewers independently evaluated all relevant studies. Administrative data relevant to CI in Kazakhstan were obtained from the Ministry of Health. Three relevant systematic reviews and an health technology assessment report were found. There was evidence of incremental benefits from bilateral CI but the quality of the available studies was poor and there was little information on longer term outcomes. No conclusions could be drawn regarding later incremental improvements to speech perception, learning, and quality of life. To date, in the Republic of Kazakhstan there is not full coverage of audiological screening due to the lack of medical equipment. This leads to late detection of hearing-impaired children and a long rehabilitation period, requiring more resources. Age of implantation in children is late and only a small minority attend general schools. The clinical effectiveness of bilateral CI, an expensive health technology, requires further study. Given the current situation in Kazakhstan with audiological screening and access to unilateral CI, there appeared to be other priorities for improving services for children with profound hearing impairment.

  1. Binaural enhancement for bilateral cochlear implant users.

    Science.gov (United States)

    Brown, Christopher A

    2014-01-01

    Bilateral cochlear implant (BCI) users receive limited binaural cues and, thus, show little improvement to speech intelligibility from spatial cues. The feasibility of a method for enhancing the binaural cues available to BCI users is investigated. This involved extending interaural differences of levels, which typically are restricted to high frequencies, into the low-frequency region. Speech intelligibility was measured in BCI users listening over headphones and with direct stimulation, with a target talker presented to one side of the head in the presence of a masker talker on the other side. Spatial separation was achieved by applying either naturally occurring binaural cues or enhanced cues. In this listening configuration, BCI patients showed greater speech intelligibility with the enhanced binaural cues than with naturally occurring binaural cues. In some situations, it is possible for BCI users to achieve greater speech intelligibility when binaural cues are enhanced by applying interaural differences of levels in the low-frequency region.

  2. Binaural Pitch Fusion in Bilateral Cochlear Implant Users.

    Science.gov (United States)

    Reiss, Lina A J; Fowler, Jennifer R; Hartling, Curtis L; Oh, Yonghee

    Binaural pitch fusion is the fusion of stimuli that evoke different pitches between the ears into a single auditory image. Individuals who use hearing aids or bimodal cochlear implants (CIs) experience abnormally broad binaural pitch fusion, such that sounds differing in pitch by as much as 3-4 octaves are fused across ears, leading to spectral averaging and speech perception interference. The goal of this study was to determine if adult bilateral CI users also experience broad binaural pitch fusion. Stimuli were pulse trains delivered to individual electrodes. Fusion ranges were measured using simultaneous, dichotic presentation of reference and comparison stimuli in opposite ears, and varying the comparison stimulus to find the range that fused with the reference stimulus. Bilateral CI listeners had binaural pitch fusion ranges varying from 0 to 12 mm (average 6.1 ± 3.9 mm), where 12 mm indicates fusion over all electrodes in the array. No significant correlations of fusion range were observed with any subject factors related to age, hearing loss history, or hearing device history, or with any electrode factors including interaural electrode pitch mismatch, pitch match bandwidth, or within-ear electrode discrimination abilities. Bilateral CI listeners have abnormally broad fusion, similar to hearing aid and bimodal CI listeners. This broad fusion may explain the variability of binaural benefits for speech perception in quiet and in noise in bilateral CI users.

  3. Objective and subjective measures of simultaneous vs sequential bilateral cochlear implants in adults : A randomized clinical trial

    NARCIS (Netherlands)

    Kraaijenga, Véronique J.C.; Ramakers, Geerte G.J.; Smulders, Yvette E.; Van Zon, Alice; Stegeman, Inge; Smit, Adriana L.; Stokroos, Robert J.; Hendrice, Nadia; Free, Rolien H.; Maat, Bert; Frijns, Johan H M; Briaire, Jeroen J; Mylanus, Emmanuel A M; Huinck, Wendy J.; van Zanten, Gijsbert A.; Grolman, Wilko

    2017-01-01

    IMPORTANCE: To date, no randomized clinical trial on the comparison between simultaneous and sequential bilateral cochlear implants (BiCIs) has been performed.  OBJECTIVE: To investigate the hearing capabilities and the self-reported benefits of simultaneous BiCIs compared with those of sequential

  4. Objective and Subjective Measures of Simultaneous vs Sequential Bilateral Cochlear Implants in Adults: A Randomized Clinical Trial

    NARCIS (Netherlands)

    Kraaijenga, V.J.; Ramakers, G.G.; Smulders, Y.E.; Zon, A. van; Stegeman, I.; Smit, A.L.; Stokroos, R.J.; Hendrice, N.; Free, R.H.; Maat, B.; Frijns, J.H.; Briaire, J.J.; Mylanus, E.A.M.; Huinck, W.J.; Zanten, G.A.; Grolman, W.

    2017-01-01

    Importance: To date, no randomized clinical trial on the comparison between simultaneous and sequential bilateral cochlear implants (BiCIs) has been performed. Objective: To investigate the hearing capabilities and the self-reported benefits of simultaneous BiCIs compared with those of sequential

  5. Simultaneous versus sequential bilateral cochlear implants in adults: Cost analysis in a US setting.

    Science.gov (United States)

    Trinidade, Aaron; Page, Joshua C; Kennett, Sarah W; Cox, Matthew D; Dornhoffer, John L

    2017-11-01

    From a purely surgical efficiency point of view, simultaneous cochlear implantation (SimCI) is more cost-effective than sequential cochlear implantation (SeqCI) when total direct costs are considered (implant and hospital costs). However, in a setting where only SeqCI is practiced and a proportion of initially unilaterally implanted patients do not progress to a second implant, this may not be the case, especially when audiological costs are factored in. We present a cost analysis of such a scenario as would occur in our institution. Retrospective review and cost analysis. Between 2005 and 2015, 370 patients fulfilled the audiological criteria for bilateral implantation. Of those, 267 (72.1%) underwent unilateral cochlear implantation only, 101 (27.3%) progressed to SeqCI, and two underwent SimCI. The total hospital, surgical, and implant costs, and initial implant stimulation series audiological costs between August 2015 and August 2016 (29 adult patients) were used in this analysis. The total hospital, surgical, and implant costs for this period was $2,731,360.42. Based on previous local trends, if a projected eight (27.3%) of these patients decide to progress to SeqCI, this will cost an additional $750,811.04, resulting in an overall total of $3,482,171.46 for these 29 patients. Had all 29 undergone SimCI, the total projected cost would have been $3,332,991.75, representing a total potential saving of $149,179.67 (4.3%). In institutions where only SeqCI is allowed in adults, overall patient management may cost marginally more than if SimCI were practiced. This will be of interest to CI programs and health insurance companies. 4. Laryngoscope, 127:2615-2618, 2017. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.

  6. Cranial MRI in a young child with cochlear implants after bilateral magnet removal.

    Science.gov (United States)

    Helbig, Silke; Stöver, Timo; Burck, Iris; Kramer, Sabine

    2017-12-01

    A young bilateral cochlear implant (CI) user required magnetic resonance imaging (MRI) to determine the cause of hydrocephalus. The images obtained with the CIs in place were not diagnostically useful due to large artefacts generated by the CI magnets. We obtained useful images by bilaterally explanting the CI-magnets and replacing them with non-magnetic placeholder dummies then conducted the imaging. The artefact in the new images was greatly reduced and the images were diagnostically useful. Lastly, we explanted the dummies and reimplanted the CI-magnets. This procedure should be useful to obtain useful images in CI users. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Spectral-Temporal Modulated Ripple Discrimination by Children With Cochlear Implants.

    Science.gov (United States)

    Landsberger, David M; Padilla, Monica; Martinez, Amy S; Eisenberg, Laurie S

    A postlingually implanted adult typically develops hearing with an intact auditory system, followed by periods of deafness (or near deafness) and adaptation to the implant. For an early implanted child whose brain is highly plastic, the auditory system matures with consistent input from a cochlear implant. It is likely that the auditory system of early implanted cochlear implant users is fundamentally different than postlingually implanted adults. The purpose of this study is to compare the basic psychophysical capabilities and limitations of these two populations on a spectral resolution task to determine potential effects of early deprivation and plasticity. Performance on a spectral resolution task (Spectral-temporally Modulated Ripple Test [SMRT]) was measured for 20 bilaterally implanted, prelingually deafened children (between 5 and 13 years of age) and 20 hearing children within the same age range. Additionally, 15 bilaterally implanted, postlingually deafened adults, and 10 hearing adults were tested on the same task. Cochlear implant users (adults and children) were tested bilaterally, and with each ear alone. Hearing listeners (adults and children) were tested with the unprocessed SMRT and with a vocoded version that simulates an 8-channel cochlear implant. For children with normal hearing, a positive correlation was found between age and SMRT score for both the unprocessed and vocoded versions. Older hearing children performed similarly to hearing adults in both the unprocessed and vocoded test conditions. However, for children with cochlear implants, no significant relationship was found between SMRT score and chronological age, age at implantation, or years of implant experience. Performance by children with cochlear implants was poorer than performance by cochlear implanted adults. It was also found that children implanted sequentially tended to have better scores with the first implant compared with the second implant. This difference was not

  8. [Cochlear implantation through the middle fossa approach].

    Science.gov (United States)

    Szyfter, W; Colletti, V; Pruszewicz, A; Kopeć, T; Szymiec, E; Kawczyński, M; Karlik, M

    2001-01-01

    The inner part of cochlear implant is inserted into inner ear during surgery through mastoid and middle ear. It is a classical method, used in the majority cochlear centers in the world. This is not a suitable method in case of chronic otitis media and middle ear malformation. In these cases Colletti proposed the middle fossa approach and cochlear implant insertion omitting middle ear structures. In patient with bilateral chronic otitis media underwent a few ears operations without obtaining dry postoperative cavity. Cochlear implantation through the middle fossa approach was performed in this patient. The bone fenster was cut, temporal lobe was bent and petrosus pyramid upper surface was exposed. When the superficial petrosal greater nerve, facial nerve and arcuate eminence were localised, the cochlear was open in the basal turn and electrode were inserted. The patient achieves good results in the postoperative speech rehabilitation. It confirmed Colletti tesis that deeper electrode insertion in the cochlear implantation through the middle fossa approach enable use of low and middle frequencies, which are very important in speech understanding.

  9. Sequential bilateral cochlear implantation in children: parents' perspective and device use.

    NARCIS (Netherlands)

    Sparreboom, M.; Leeuw, A.R.; Snik, A.F.M.; Mylanus, E.A.M.

    2012-01-01

    OBJECTIVE: The purpose of this study was (1) to measure parental expectations before surgery of a sequentially placed second cochlear implant and compare these results with parental observations postoperatively and (2) to measure device use of the second cochlear implant and compare to unilateral

  10. A Case of Cochlear Implantation in Bromate-Induced Bilateral Sudden Deafness.

    Science.gov (United States)

    Eom, Tae-Ho; Lee, Sungsu; Cho, Hyong-Ho; Cho, Yong-Beom

    2015-04-01

    Despite the well-established nature of bromate-induced ototoxicity, cochlear implantation after bromate intoxication has been rarely documented. We hereby present a case of a 51-year-old female deafened completely after bromate ingestion. Her hearing was not restored by systemic steroid treatment and hearing aids were of no use. A cochlear implantation was performed on her right ear 3 months after the bromate ingestion. In bromate intoxication cases, early monitoring of hearing level is necessary and other drugs with potential ototoxicity should be avoided. The outcome of cochlear implantation was excellent in this case of bromate-induced deafness.

  11. Spatial Release from Masking in Adults with Bilateral Cochlear Implants: Effects of Distracter Azimuth and Microphone Location

    Science.gov (United States)

    Davis, Timothy J.; Gifford, René H.

    2018-01-01

    Purpose: The primary purpose of this study was to derive spatial release from masking (SRM) performance-azimuth functions for bilateral cochlear implant (CI) users to provide a thorough description of SRM as a function of target/distracter spatial configuration. The secondary purpose of this study was to investigate the effect of the microphone…

  12. Audio-visual speech perception in prelingually deafened Japanese children following sequential bilateral cochlear implantation.

    Science.gov (United States)

    Yamamoto, Ryosuke; Naito, Yasushi; Tona, Risa; Moroto, Saburo; Tamaya, Rinko; Fujiwara, Keizo; Shinohara, Shogo; Takebayashi, Shinji; Kikuchi, Masahiro; Michida, Tetsuhiko

    2017-11-01

    An effect of audio-visual (AV) integration is observed when the auditory and visual stimuli are incongruent (the McGurk effect). In general, AV integration is helpful especially in subjects wearing hearing aids or cochlear implants (CIs). However, the influence of AV integration on spoken word recognition in individuals with bilateral CIs (Bi-CIs) has not been fully investigated so far. In this study, we investigated AV integration in children with Bi-CIs. The study sample included thirty one prelingually deafened children who underwent sequential bilateral cochlear implantation. We assessed their responses to congruent and incongruent AV stimuli with three CI-listening modes: only the 1st CI, only the 2nd CI, and Bi-CIs. The responses were assessed in the whole group as well as in two sub-groups: a proficient group (syllable intelligibility ≥80% with the 1st CI) and a non-proficient group (syllable intelligibility effect in each of the three CI-listening modes. AV integration responses were observed in a subset of incongruent AV stimuli, and the patterns observed with the 1st CI and with Bi-CIs were similar. In the proficient group, the responses with the 2nd CI were not significantly different from those with the 1st CI whereas in the non-proficient group the responses with the 2nd CI were driven by visual stimuli more than those with the 1st CI. Our results suggested that prelingually deafened Japanese children who underwent sequential bilateral cochlear implantation exhibit AV integration abilities, both in monaural listening as well as in binaural listening. We also observed a higher influence of visual stimuli on speech perception with the 2nd CI in the non-proficient group, suggesting that Bi-CIs listeners with poorer speech recognition rely on visual information more compared to the proficient subjects to compensate for poorer auditory input. Nevertheless, poorer quality auditory input with the 2nd CI did not interfere with AV integration with binaural

  13. EEG frontal asymmetry related to pleasantness of music perception in healthy children and cochlear implanted users.

    Science.gov (United States)

    Vecchiato, G; Maglione, A G; Scorpecci, A; Malerba, P; Marsella, P; Di Francesco, G; Vitiello, S; Colosimo, A; Babiloni, Fabio

    2012-01-01

    Interestingly, the international debate about the quality of music fruition for cochlear implanted users does not take into account the hypothesis that bilateral users could perceive music in a more pleasant way with respect to monolateral users. In this scenario, the aim of the present study was to investigate if cerebral signs of pleasantness during music perception in healthy child are similar to those observed in monolateral and in bilateral cochlear implanted users. In fact, previous observations in literature on healthy subjects have indicated that variations of the frontal EEG alpha activity are correlated with the perceived pleasantness of the sensory stimulation received (approach-withdrawal theory). In particular, here we described differences between cortical activities estimated in the alpha frequency band for a healthy child and in patients having a monolateral or a bilateral cochlear implant during the fruition of a musical cartoon. The results of the present analysis showed that the alpha EEG asymmetry patterns observed in a healthy child and that of a bilateral cochlear implanted patient are congruent with the approach-withdrawal theory. Conversely, the scalp topographic distribution of EEG power spectra in the alpha band resulting from the monolateral cochlear user presents a different EEG pattern from the normal and bilateral implanted patients. Such differences could be explained at the light of the approach-withdrawal theory. In fact, the present findings support the hypothesis that a monolateral cochlear implanted user could perceive the music in a less pleasant way when compared to a healthy subject or to a bilateral cochlear user.

  14. Comparing Binaural Pre-processing Strategies II: Speech Intelligibility of Bilateral Cochlear Implant Users.

    Science.gov (United States)

    Baumgärtel, Regina M; Hu, Hongmei; Krawczyk-Becker, Martin; Marquardt, Daniel; Herzke, Tobias; Coleman, Graham; Adiloğlu, Kamil; Bomke, Katrin; Plotz, Karsten; Gerkmann, Timo; Doclo, Simon; Kollmeier, Birger; Hohmann, Volker; Dietz, Mathias

    2015-12-30

    Several binaural audio signal enhancement algorithms were evaluated with respect to their potential to improve speech intelligibility in noise for users of bilateral cochlear implants (CIs). 50% speech reception thresholds (SRT50) were assessed using an adaptive procedure in three distinct, realistic noise scenarios. All scenarios were highly nonstationary, complex, and included a significant amount of reverberation. Other aspects, such as the perfectly frontal target position, were idealized laboratory settings, allowing the algorithms to perform better than in corresponding real-world conditions. Eight bilaterally implanted CI users, wearing devices from three manufacturers, participated in the study. In all noise conditions, a substantial improvement in SRT50 compared to the unprocessed signal was observed for most of the algorithms tested, with the largest improvements generally provided by binaural minimum variance distortionless response (MVDR) beamforming algorithms. The largest overall improvement in speech intelligibility was achieved by an adaptive binaural MVDR in a spatially separated, single competing talker noise scenario. A no-pre-processing condition and adaptive differential microphones without a binaural link served as the two baseline conditions. SRT50 improvements provided by the binaural MVDR beamformers surpassed the performance of the adaptive differential microphones in most cases. Speech intelligibility improvements predicted by instrumental measures were shown to account for some but not all aspects of the perceptually obtained SRT50 improvements measured in bilaterally implanted CI users. © The Author(s) 2015.

  15. [Cochlear implant in children: rational, indications and cost/efficacy].

    Science.gov (United States)

    Martini, A; Bovo, R; Trevisi, P; Forli, F; Berrettini, S

    2013-06-01

    this advantage persists in the subsequent years. With regard to cochlear implantation in children older than 12 months the studies show better hearing and linguistic results in children implanted at earlier ages. A sensitive period under 24-36 months has been identified over which cochlear implantation is reported to be less effective in terms of improvement in speech and hearing results. With regard to clinical effectiveness of bilateral cochlear implantation, greater benefits from bilateral implants compared to monolateral ones when assessing hearing in quiet and in noise and in sound localization abilities are reported to be present in both case of simultaneous or sequential bilateral implantation. However, with regard to the delay between the surgeries in sequential bilateral implantation, although benefit is reported to be present even after very long delays, on average long delays between surgeries seems to negatively affect the outcome with the second implant. With regard to benefits after cochlear implantation in children with multiple disabilities, benefits in terms of speech perception and communication as well as in quality of the daily life are reported even if benefits are slower and lower in comparison to those generally attained by implanted children without additional disabilities. Regarding the costs/efficacy ratio, the CI is expensive, in particular because of the cost of the high technological device, long life support, but even if healthcare costs are high, the savings in terms of indirect costs and quality of life are important. The CI, in fact, has a positive impact in terms of quality of life.

  16. Transcanal labyrinthectomy for intractable vertigo after unilateral cochlear implantation.

    Science.gov (United States)

    Heidenreich, Katherine D; Basura, Gregory J; Zwolan, Teresa A; El-Kashlan, Hussam K; Telian, Steven A

    2011-10-01

    Document the use of transcanal labyrinthectomy to treat disabling attacks of vertigo after unilateral cochlear implantation. A 46-year-old woman with severe-profound bilateral sensorineural hearing loss secondary to enlarged vestibular aqueducts underwent cochlear implantation for her right ear with a Nucleus Freedom device. The surgery was uneventful, and postoperative imaging confirmed that the electrode was positioned properly. She developed episodic vertigo 10 to 14 days after the implant surgery, which failed to improve with aggressive vestibular rehabilitation therapy. Plugging of the round window for possible perilymphatic fistula did not relieve her symptoms. Right transcanal labyrinthectomy supplemented by filling the vestibule with gentamicin-soaked Gelfoam and then a customized vestibular rehabilitation program. Comparison of vestibular symptoms and cochlear implant performance before and after transcanal labyrinthectomy. The patient had immediate relief of symptoms, and the function of the cochlear implant was not adversely affected. Transcanal labyrinthectomy may be an effective method to ablate the vestibular end organ after unilateral cochlear implantation. It can offer relief of disabling vertigo without adversely affecting the performance of the implant.

  17. Availability of binaural cues for pediatric bilateral cochlear implant recipients.

    Science.gov (United States)

    Sheffield, Sterling W; Haynes, David S; Wanna, George B; Labadie, Robert F; Gifford, René H

    2015-03-01

    Bilateral implant recipients theoretically have access to binaural cues. Research in postlingually deafened adults with cochlear implants (CIs) indicates minimal evidence for true binaural hearing. Congenitally deafened children who experience spatial hearing with bilateral CIs, however, might perceive binaural cues in the CI signal differently. There is limited research examining binaural hearing in children with CIs, and the few published studies are limited by the use of unrealistic speech stimuli and background noise. The purposes of this study were to (1) replicate our previous study of binaural hearing in postlingually deafened adults with AzBio sentences in prelingually deafened children with the pediatric version of the AzBio sentences, and (2) replicate previous studies of binaural hearing in children with CIs using more open-set sentences and more realistic background noise (i.e., multitalker babble). The study was a within-participant, repeated-measures design. The study sample consisted of 14 children with bilateral CIs with at least 25 mo of listening experience. Speech recognition was assessed using sentences presented in multitalker babble at a fixed signal-to-noise ratio. Test conditions included speech at 0° with noise presented at 0° (S0N0), on the side of the first CI (90° or 270°) (S0N1stCI), and on the side of the second CI (S0N2ndCI) as well as speech presented at 0° with noise presented semidiffusely from eight speakers at 45° intervals. Estimates of summation, head shadow, squelch, and spatial release from masking were calculated. Results of test conditions commonly reported in the literature (S0N0, S0N1stCI, S0N2ndCI) are consistent with results from previous research in adults and children with bilateral CIs, showing minimal summation and squelch but typical head shadow and spatial release from masking. However, bilateral benefit over the better CI with speech at 0° was much larger with semidiffuse noise. Congenitally deafened

  18. Surgical timing for bilateral simultaneous cochlear implants: When is best?

    Science.gov (United States)

    Franchella, Sebastiano; Bovo, Roberto; Bandolin, Luigia; Gheller, Flavia; Montino, Silvia; Borsetto, Daniele; Ghiselli, Sara; Martini, Alessandro

    2018-06-01

    Hearing loss is considered the most common congenital disease and the prevalence of neonatal deafness can be estimated between 1 and 2 cases per 1000 live births. Infant deafness must be diagnosed as early as possible and an effective therapeutic intervention needs to be carried out in order to avoid the serious consequences of hearing deprivation during the evolutionary period: alterations in the development of central auditory pathways and lack of language acquisition. The cochlear implant (CI) has proved to be the best instrument to solve the problem of auditory deprivation. In particular, the bilateral CI gives the patient access to binaural hearing which results in benefits in terms of sound localisation and discrimination. The optimal age of application of the CI is a widely discussed topic in the scientific community and the current guidelines indicate a period between 12 and 24 months of age, even though the supporters of the application before 12 months of age are nowadays increasing. The study is observational, retrospective, monocentric. 49 paediatric patients (<18 years) with simultaneous bilateral CIs were included. The audiometric threshold and speech tests were carried out during the follow-up 3, 6 and 12 months after the CIs activation and when the patient reached 2 years of age. The statistical analysis showed that undergoing bilateral implantation surgery before 2 years of age allows a satisfactory audiometric performance, while there are no particular benefits in performing the surgery before 1 year of age. As far as the speech outcome is concerned, the statistical analysis didn't show significant correlation between the earlier age of implantation and better speech performance if the operation is carried out before 2.5 years of age. The results of the study indicate that the optimal age to perform the simultaneous bilateral CIs surgery is between 12 and 24 months, without demonstrating any particular benefit in carrying out the procedure before

  19. Characterization of Cochlear, Vestibular and Cochlear-Vestibular Electrically Evoked Compound Action Potentials in Patients with a Vestibulo-Cochlear Implant

    Directory of Open Access Journals (Sweden)

    T. A. K. Nguyen

    2017-11-01

    Full Text Available The peripheral vestibular system is critical for the execution of activities of daily life as it provides movement and orientation information to motor and sensory systems. Patients with bilateral vestibular hypofunction experience a significant decrease in quality of life and have currently no viable treatment option. Vestibular implants could eventually restore vestibular function. Most vestibular implant prototypes to date are modified cochlear implants to fast-track development. These use various objective measurements, such as the electrically evoked compound action potential (eCAP, to supplement behavioral information. We investigated whether eCAPs could be recorded in patients with a vestibulo-cochlear implant. Specifically, eCAPs were successfully recorded for cochlear and vestibular setups, as well as for mixed cochlear-vestibular setups. Similarities and slight differences were found for the recordings of the three setups. These findings demonstrated the feasibility of eCAP recording with a vestibulo-cochlear implant. They could be used in the short term to reduce current spread and avoid activation of non-targeted neurons. More research is warranted to better understand the neural origin of vestibular eCAPs and to utilize them for clinical applications.

  20. Objective and Subjective Measures of Simultaneous vs Sequential Bilateral Cochlear Implants in Adults A Randomized Clinical Trial : A Randomized Clinical Trial

    NARCIS (Netherlands)

    Kraaijenga, Véronique J C; Ramakers, Geerte G J; Smulders, Yvette E; van Zon, Alice; Stegeman, Inge; Smit, Adriana L; Stokroos, Robert J; Hendrice, Nadia; Free, Rolien H; Maat, Bert; Frijns, Johan H M; Briaire, Jeroen J; Mylanus, E A M; Huinck, Wendy J; Van Zanten, Gijsbert A; Grolman, Wilko

    IMPORTANCE To date, no randomized clinical trial on the comparison between simultaneous and sequential bilateral cochlear implants (BiCIs) has been performed. OBJECTIVE To investigate the hearing capabilities and the self-reported benefits of simultaneous BiCIs compared with those of sequential

  1. Technical devices for hearing-impaired individuals: cochlear implants and brain stem implants - developments of the last decade.

    Science.gov (United States)

    Müller, Joachim

    2005-01-01

    Over the past two decades, the fascinating possibilities of cochlear implants for congenitally deaf or deafened children and adults developed tremendously and created a rapidly developing interdisciplinary research field.The main advancements of cochlear implantation in the past decade are marked by significant improvement of hearing and speech understanding in CI users. These improvements are attributed to the enhancement of speech coding strategies.The Implantation of more (and increasingly younger) children as well as the possibilities of the restoration of binaural hearing abilities with cochlear implants reflect the high standards reached by this development. Despite this progress, modern cochlear implants do not yet enable normal speech understanding, not even for the best patients. In particular speech understanding in noise remains problematic [1]. Until the mid 1990ies research concentrated on unilateral implantation. Remarkable and effective improvements have been made with bilateral implantation since 1996. Nowadays an increasing numbers of patients enjoy these benefits.

  2. Cochlear implantation in patient with Dandy-walker syndrome.

    Science.gov (United States)

    de Oliveira, Adriana Kosma Pires; Hamerschmidt, Rogerio; Mocelin, Marcos; Rezende, Rodrigo K

    2012-07-01

     Dandy Walker Syndrome is a congenital abnormality in the central nervous system, characterized by a deficiency in the development of middle cerebelar structures, cystic dilatation of the posterior pit communicating with the fourth ventricle and upward shift of the transverse sinuses, tentorium and dyes. Among the clinical signs are occipital protuberances, a progressive increase of the skull, bowing before the fontanels, papilledema, ataxia, gait disturbances, nystagmus, and intellectual impairment.  To describe a case of female patient, 13 years old with a diagnosis of this syndrome and bilateral hearing loss underwent cochlear implant surgery under local anesthesia and sedation.  CGS, 13 years old female was referred to the Otolaryngological Department of Otolaryngology Institute of Parana with a diagnosis of "Dandy-Walker syndrome" for Otolaryngological evaluation for bilateral hearing loss with no response to the use of hearing aids. Final Comments: The field of cochlear implants is growing rapidly. We believe that the presence of Dandy-Walker syndrome cannot be considered a contraindication to the performance of cochlear implant surgery, and there were no surgical complications due to neurological disorders with very favorable results for the patient who exhibits excellent discrimination. It has less need for lip reading with improvement in speech quality.

  3. Cochlear implantation in patient with Dandy-walker syndrome

    Directory of Open Access Journals (Sweden)

    Oliveira, Adriana Kosma Pires de

    2012-01-01

    Full Text Available Introduction: Dandy Walker Syndrome is a congenital abnormality in the central nervous system, characterized by a deficiency in the development of middle cerebelar structures, cystic dilatation of the posterior pit communicating with the fourth ventricle and upward shift of the transverse sinuses, tentorium and dyes. Among the clinical signs are occipital protuberances, a progressive increase of the skull, bowing before the fontanels, papilledema, ataxia, gait disturbances, nystagmus, and intellectual impairment. Objectives: To describe a case of female patient, 13 years old with a diagnosis of this syndrome and bilateral hearing loss underwent cochlear implant surgery under local anesthesia and sedation. Case Report: CGS, 13 years old female was referred to the Otolaryngological Department of Otolaryngology Institute of Parana with a diagnosis of "Dandy-Walker syndrome" for Otolaryngological evaluation for bilateral hearing loss with no response to the use of hearing aids. Final Comments: The field of cochlear implants is growing rapidly. We believe that the presence of Dandy-Walker syndrome cannot be considered a contraindication to the performance of cochlear implant surgery, and there were no surgical complications due to neurological disorders with very favorable results for the patient who exhibits excellent discrimination. It has less need for lip reading with improvement in speech quality.

  4. Benefits and Risks of Cochlear Implants

    Science.gov (United States)

    ... and Medical Procedures Implants and Prosthetics Cochlear Implants Benefits and Risks of Cochlear Implants Share Tweet Linkedin ... the Use of Cochlear Implants What are the Benefits of Cochlear Implants? For people with implants: Hearing ...

  5. Significant regional differences in Denmark in outcome after cochlear implants in children

    DEFF Research Database (Denmark)

    Percy-Smith, Lone; Busch, Georg Walter; Sandahl, Minna

    2012-01-01

    The objectives of the present study were to study regional differences in outcome for a paediatric cochlear implant (CI) population after the introduction of universal neonatal hearing screening (UNHS) and bilateral implantation in Denmark....

  6. Audiological outcomes of cochlear implantation in Waardenburg Syndrome

    Directory of Open Access Journals (Sweden)

    Magalhães, Ana Tereza de Matos

    2014-01-01

    Full Text Available Introduction: The most relevant clinical symptom in Waardenburg syndrome is profound bilateral sensorioneural hearing loss. Aim: To characterize and describe hearing outcomes after cochlear implantation in patients with Waardenburg syndrome to improve preoperative expectations. Method: This was an observational and retrospective study of a series of cases. Children who were diagnosed with Waardenburg syndrome and who received a multichannel cochlear implant between March 1999 and July 2012 were included in the study. Intraoperative neural response telemetry, hearing evaluation, speech perception, and speech production data before and after surgery were assessed. Results: During this period, 806 patients received a cochlear implant and 10 of these (1.2% were diagnosed with Waardenburg syndrome. Eight of the children received a Nucleus 24® implant and 1 child and 1 adult received a DigiSonic SP implant. The mean age at implantation was 44 months among the children. The average duration of use of a cochlear implant at the time of the study was 43 months. Intraoperative neural responses were present in all cases. Patients who could use the speech processor effectively had a pure tone average of 31 dB in free-field conditions. In addition, the MUSS and MAIS questionnaires revealed improvements in speech perception and production. Four patients did not have a good outcome, which might have been associated with ineffective use of the speech processor. Conclusion: Despite the heterogeneity of the group, patients with Waardenburg syndrome who received cochlear implants were found to have hearing thresholds that allowed access to speech sounds. However, patients who received early intervention and rehabilitation showed better evolution of auditory perception.

  7. Audiological outcomes of cochlear implantation in Waardenburg Syndrome.

    Science.gov (United States)

    Magalhães, Ana Tereza de Matos; Samuel, Paola Angélica; Goffi-Gomez, Maria Valeria Schimdt; Tsuji, Robinson Koji; Brito, Rubens; Bento, Ricardo Ferreira

    2013-07-01

     The most relevant clinical symptom in Waardenburg syndrome is profound bilateral sensorioneural hearing loss.  To characterize and describe hearing outcomes after cochlear implantation in patients with Waardenburg syndrome to improve preoperative expectations.  This was an observational and retrospective study of a series of cases. Children who were diagnosed with Waardenburg syndrome and who received a multichannel cochlear implant between March 1999 and July 2012 were included in the study. Intraoperative neural response telemetry, hearing evaluation, speech perception, and speech production data before and after surgery were assessed.  During this period, 806 patients received a cochlear implant and 10 of these (1.2%) were diagnosed with Waardenburg syndrome. Eight of the children received a Nucleus 24(®) implant and 1 child and 1 adult received a DigiSonic SP implant. The mean age at implantation was 44 months among the children. The average duration of use of a cochlear implant at the time of the study was 43 months. Intraoperative neural responses were present in all cases. Patients who could use the speech processor effectively had a pure tone average of 31 dB in free-field conditions. In addition, the MUSS and MAIS questionnaires revealed improvements in speech perception and production. Four patients did not have a good outcome, which might have been associated with ineffective use of the speech processor.  Despite the heterogeneity of the group, patients with Waardenburg syndrome who received cochlear implants were found to have hearing thresholds that allowed access to speech sounds. However, patients who received early intervention and rehabilitation showed better evolution of auditory perception.

  8. Cochlear Implantation in Siblings With Refsum's Disease.

    Science.gov (United States)

    Stähr, Kerstin; Kuechler, Alma; Gencik, Martin; Arnolds, Judith; Dendy, Meaghan; Lang, Stephan; Arweiler-Harbeck, Diana

    2017-08-01

    Whether the origin of severe hearing loss in Refsum's syndrome is caused by cochlear impairment or retrocochlear degeneration remains unclear. This case report aims to investigate hearing performance before and after cochlear implantation to shed light on this question. Also, identification of new mutations causing Refsum's syndrome would be helpful in generating additional means of diagnosis. A family of 4 individuals was subjected to genetic testing. Two siblings (56 and 61 years old) suffered from severe hearing and vision loss and received bilateral cochlear implants. Genetic analysis, audiological outcome, and clinical examinations were performed. One new mutation in the PHYH gene (c.768del63bp) causing Refsum's disease was found. Preoperative distortion product otoacoustic emissions (DPAOEs) were absent. Postoperative speech perception in Freiburger speech test was 100% for bisyllabic words and 85% (patient No. 1) and 65% (patient No. 2), respectively, for monosyllabic words. Five years after implantation, speech perception remained stable for bisyllabic words but showed decreasing capabilities for monosyllabic words. A new mutation causing Refsum's disease is presented. Cochlear implantation in case of severe hearing loss leads to an improvement in speech perception and should be recommended for patients with Refsum's disease, especially when the hearing loss is combined with a severe loss of vision. Decrease of speech perception in the long-term follow-up could indicate an additional retrocochlear degeneration.

  9. Trends in cochlear implants.

    Science.gov (United States)

    Zeng, Fan-Gang

    2004-01-01

    More than 60,000 people worldwide use cochlear implants as a means to restore functional hearing. Although individual performance variability is still high, an average implant user can talk on the phone in a quiet environment. Cochlear-implant research has also matured as a field, as evidenced by the exponential growth in both the patient population and scientific publication. The present report examines current issues related to audiologic, clinical, engineering, anatomic, and physiologic aspects of cochlear implants, focusing on their psychophysical, speech, music, and cognitive performance. This report also forecasts clinical and research trends related to presurgical evaluation, fitting protocols, signal processing, and postsurgical rehabilitation in cochlear implants. Finally, a future landscape in amplification is presented that requires a unique, yet complementary, contribution from hearing aids, middle ear implants, and cochlear implants to achieve a total solution to the entire spectrum of hearing loss treatment and management.

  10. Using ILD or ITD Cues for Sound Source Localization and Speech Understanding in a Complex Listening Environment by Listeners with Bilateral and with Hearing-Preservation Cochlear Implants

    Science.gov (United States)

    Loiselle, Louise H.; Dorman, Michael F.; Yost, William A.; Cook, Sarah J.; Gifford, Rene H.

    2016-01-01

    Purpose: To assess the role of interaural time differences and interaural level differences in (a) sound-source localization, and (b) speech understanding in a cocktail party listening environment for listeners with bilateral cochlear implants (CIs) and for listeners with hearing-preservation CIs. Methods: Eleven bilateral listeners with MED-EL…

  11. Binaural unmasking of multi-channel stimuli in bilateral cochlear implant users.

    Science.gov (United States)

    Van Deun, Lieselot; van Wieringen, Astrid; Francart, Tom; Büchner, Andreas; Lenarz, Thomas; Wouters, Jan

    2011-10-01

    Previous work suggests that bilateral cochlear implant users are sensitive to interaural cues if experimental speech processors are used to preserve accurate interaural information in the electrical stimulation pattern. Binaural unmasking occurs in adults and children when an interaural delay is applied to the envelope of a high-rate pulse train. Nevertheless, for speech perception, binaural unmasking benefits have not been demonstrated consistently, even with coordinated stimulation at both ears. The present study aimed at bridging the gap between basic psychophysical performance on binaural signal detection tasks on the one hand and binaural perception of speech in noise on the other hand. Therefore, binaural signal detection was expanded to multi-channel stimulation and biologically relevant interaural delays. A harmonic complex, consisting of three sinusoids (125, 250, and 375 Hz), was added to three 125-Hz-wide noise bands centered on the sinusoids. When an interaural delay of 700 μs was introduced, an average BMLD of 3 dB was established. Outcomes are promising in view of real-life benefits. Future research should investigate the generalization of the observed benefits for signal detection to speech perception in everyday listening situations and determine the importance of coordination of bilateral speech processors and accentuation of envelope cues.

  12. Retrolabyrinthine approach for cochlear nerve preservation in neurofibromatosis type 2 and simultaneous cochlear implantation

    Directory of Open Access Journals (Sweden)

    Bento, Ricardo Ferreira

    2014-01-01

    Full Text Available Introduction: Few cases of cochlear implantation (CI in neurofibromatosis type 2 (NF2 patients had been reported in the literature. The approaches described were translabyrinthine, retrosigmoid or middle cranial fossa. Objectives: To describe a case of a NF2- deafened-patient who underwent to vestibular schwannoma resection via RLA with cochlear nerve preservation and CI through the round window, at the same surgical time. Resumed Report: A 36-year-old woman with severe bilateral hearing loss due to NF2 was submitted to vestibular schwannoma resection and simultaneous CI. Functional assessment of cochlear nerve was performed by electrical promontory stimulation. Complete tumor removal was accomplishment via RLA with anatomic and functional cochlear and facial nerve preservation. Cochlear electrode array was partially inserted via round window. Sound field hearing threshold improvement was achieved. Mean tonal threshold was 46.2 dB HL. The patient could only detect environmental sounds and human voice but cannot discriminate vowels, words nor do sentences at 2 years of follow-up. Conclusion: Cochlear implantation is a feasible auditory restoration option in NF2 when cochlear anatomic and functional nerve preservation is achieved. The RLA is adequate for this purpose and features as an option for hearing preservation in NF2 patients.

  13. Cochlear implant benefits in deafness rehabilitation: PET study of temporal voice Activations

    Energy Technology Data Exchange (ETDEWEB)

    Coez, A.; Zilbovicius, M. [CEA, Serv Hosp Frederic Joliot, INSERM, Res Unit Neuroimaging and Psychiat, U797, IFR49, F-91406 Orsay (France); Zilbovicius, M.; Syrota, A.; Samson, Y. [CEA, DSV, DRM, Serv Hosp Frederic Joliot, F-91406 Orsay (France); Bizaguet, E. [Lab Correct Audit, Paris (France); Coez, A. [Univ Paris Sud 11, Paris (France); Ferrary, E.; Bouccara, D.; Mosnier, I.; Sterkers, O. [INSERM, Unit M 867, Paris (France); Ambert-Dahan, E. [Hop Beaujon, Serv ORL Chirurg Cervicofaciale, AP-HP, Clichy (France); Ferrary, E.; Bouccara, D.; Mosnier, I.; Sterkers, O. [Inst Fed Rech Claude Bernard Physiol et Pathol, IFR02, Paris (France); Samson, Y. [Hop La Pitie Salpetriere, Serv Urgences Cerebro-vasc, AP-HP, Paris (France); Samson, Y. [Univ Paris 06, Paris (France); Sterkers, O. [Univ Denis Diderot Paris 7, Paris (France)

    2008-07-01

    Cochlear implants may improve the medical and social prognosis of profound deafness. Nevertheless, some patients have experienced poor results without any clear explanations. One correlate may be an alteration in cortical voice processing. To test this hypothesis, we studied the activation of human temporal voice areas (TVA) using a well-standardized PET paradigm adapted from previous functional MRI (fMRI) studies. Methods: A PET H{sub 2}{sup 15}O activation study was performed on 3 groups of adult volunteers: normal-hearing control subjects (n 6) and cochlear-implanted post-lingually deaf patients with {>=}2 y of cochlear implant experience, with intelligibility scores in the 'Lafon monosyllabic task' {>=}80% (Good group; n 6) or {<=}20% (Poor group; n 6). Relative cerebral blood flow was measured in 3 conditions: rest, passive listening to human voice, and non-voice stimuli. Results: Compared with silence, the activations induced by non-voice stimuli were bilaterally located in the superior temporal regions in all groups. However these activations were significantly and similarly reduced in both cochlear implant groups, whereas control subjects showed supplementary activations. Compared with non-voice, the voice stimuli induced bilateral activation of the TVA along the superior temporal sulcus (STS) in both the control and the Good groups. In contrast, these activations were not detected in the Poor group, which showed only left unilateral middle STS activation. Conclusion: These results suggest that PET is an adequate method to explore cochlear implant benefits and that this benefit could be linked to the activation of the TVA. (authors)

  14. Cochlear implant benefits in deafness rehabilitation: PET study of temporal voice Activations

    International Nuclear Information System (INIS)

    Coez, A.; Zilbovicius, M.; Zilbovicius, M.; Syrota, A.; Samson, Y.; Bizaguet, E.; Coez, A.; Ferrary, E.; Bouccara, D.; Mosnier, I.; Sterkers, O.; Ambert-Dahan, E.; Ferrary, E.; Bouccara, D.; Mosnier, I.; Sterkers, O.; Samson, Y.; Samson, Y.; Sterkers, O.

    2008-01-01

    Cochlear implants may improve the medical and social prognosis of profound deafness. Nevertheless, some patients have experienced poor results without any clear explanations. One correlate may be an alteration in cortical voice processing. To test this hypothesis, we studied the activation of human temporal voice areas (TVA) using a well-standardized PET paradigm adapted from previous functional MRI (fMRI) studies. Methods: A PET H 2 15 O activation study was performed on 3 groups of adult volunteers: normal-hearing control subjects (n 6) and cochlear-implanted post-lingually deaf patients with ≥2 y of cochlear implant experience, with intelligibility scores in the 'Lafon monosyllabic task' ≥80% (Good group; n 6) or ≤20% (Poor group; n 6). Relative cerebral blood flow was measured in 3 conditions: rest, passive listening to human voice, and non-voice stimuli. Results: Compared with silence, the activations induced by non-voice stimuli were bilaterally located in the superior temporal regions in all groups. However these activations were significantly and similarly reduced in both cochlear implant groups, whereas control subjects showed supplementary activations. Compared with non-voice, the voice stimuli induced bilateral activation of the TVA along the superior temporal sulcus (STS) in both the control and the Good groups. In contrast, these activations were not detected in the Poor group, which showed only left unilateral middle STS activation. Conclusion: These results suggest that PET is an adequate method to explore cochlear implant benefits and that this benefit could be linked to the activation of the TVA. (authors)

  15. Results of a prospective surgical audit of bilateral paediatric cochlear implantation in the UK.

    Science.gov (United States)

    Broomfield, Stephen J; Murphy, John; Wild, Dominik C; Emmett, Stevan R; O'Donoghue, Gerard M

    2014-09-01

    Since being approved in 2009, bilateral simultaneous cochlear implantation (CI) has been the standard treatment for children in the UK who meet the criteria for CI. The aim was to report surgical outcomes of bilateral CI in the UK. Between January 2010 and December 2011, 14 UK CI centres collected data prospectively: demographics, aetiology, use of imaging, device type, surgery duration, use of intra-operative electrophysiology, length of stay, and post-operative complications. 1397 CI procedures in 961 CI recipients were included; 436 bilateral simultaneous, 394 bilateral sequential, and 131 unilateral. The majority (85%) were congenitally deaf. The commonest causes of acquired deafness were meningitis and cytomegalovirus infection. The median age for congenitally deaf bilateral simultaneous CI was 2.2 years, mean surgical duration 4.5 hours. 6.3% surgeries were day case procedures. Eight cases (2.0%) of planned bilateral CI had unilateral surgery. The overall major complication rate was 1.6% (0.9% excluding device failures), including explantation due to infection (0.2%), cerebrospinal fluid leak (0.2%), and meningitis (0.1%). There were no permanent facial nerve palsies and no deaths. Sixty-two (6.5%) immediate minor complications included 12 (1.3%) children with significant vestibular impairment. The complication rate was similar following bilateral CI compared to sequential and unilateral CI, and is comparable to other published series. This prospective multi-centre audit provides evidence that bilateral paediatric CI is a safe procedure in the UK, thus endorsing its role as a major therapeutic intervention in childhood deafness.

  16. Sensitivity to binaural timing in bilateral cochlear implant users.

    Science.gov (United States)

    van Hoesel, Richard J M

    2007-04-01

    Various measures of binaural timing sensitivity were made in three bilateral cochlear implant users, who had demonstrated moderate-to-good interaural time delay (ITD) sensitivity at 100 pulses-per-second (pps). Overall, ITD thresholds increased at higher pulse rates, lower levels, and shorter durations, although intersubject differences were evident. Monaural rate-discrimination thresholds, using the same stimulation parameters, showed more substantial elevation than ITDs with increased rate. ITD sensitivity with 6000 pps stimuli, amplitude-modulated at 100 Hz, was similar to that with unmodulated pulse trains at 100 pps, but at 200 and 300 Hz performance was poorer than with unmodulated signals. Measures of sensitivity to binaural beats with unmodulated pulse-trains showed that all three subjects could use time-varying ITD cues at 100 pps, but not 300 pps, even though static ITD sensitivity was relatively unaffected over that range. The difference between static and dynamic ITD thresholds is discussed in terms of relative contributions from initial and later arriving cues, which was further examined in an experiment using two-pulse stimuli as a function of interpulse separation. In agreement with the binaural-beat data, findings from that experiment showed poor discrimination of ITDs on the second pulse when the interval between pulses was reduced to a few milliseconds.

  17. Congenitally Deafblind Children and Cochlear Implants

    DEFF Research Database (Denmark)

    Dammeyer, Jesper Herup

    2008-01-01

    There has been much research conducted demonstrating the positive benefits of cochlear implantation (CI) in children who are deaf. Research on cochlear implantation in children who are both deaf and blind, however, is lacking. The purpose of this article is to present a study of 5 congenitally...... deafblind children who received cochlear implants between 2.2 and 4.2 years of age.  Ratings of video observations were used to measure the children's early communication development with and without the use of their cochlear implants. In addition, parental interviews were used to assess the benefits...... parents perceived regarding their children's cochlear implants. Two examples are included in this article to illustrate the parents' perspectives about cochlear implantation in their deafblind children. Benefits of cochlear implantation in this cohort of children included improved attention and emotional...

  18. Is there a best side for cochlear implants in post-lingual patients?

    Science.gov (United States)

    Amaral, Maria Stella Arantes do; Damico, Thiago A; Gonçales, Alina S; Reis, Ana C M B; Isaac, Myriam de Lima; Massuda, Eduardo T; Hyppolito, Miguel Angelo

    2017-07-29

    Cochlear Implant is a sensory prosthesis capable of restoring hearing in patients with severe or profound bilateral sensorineural hearing loss. To evaluate if there is a better side to be implanted in post-lingual patients. Retrospective longitudinal study. Participants were 40 subjects, of both sex, mean age of 47 years, with post-lingual hearing loss, users of unilateral cochlear implant for more than 12 months and less than 24 months, with asymmetric auditor reserve between the ears (difference of 10dBNA, In at least one of the frequencies with a response, between the ears), divided into two groups. Group A was composed of individuals with cochlear implant in the ear with better auditory reserve and Group B with auditory reserve lower in relation to the contralateral side. There was no statistical difference for the tonal auditory threshold before and after cochlear implant. A better speech perception in pre-cochlear implant tests was present in B (20%), but the final results are similar in both groups. The cochlear implant in the ear with the worst auditory residue favors a bimodal hearing, which would allow the binaural summation, without compromising the improvement of the audiometric threshold and the speech perception. Copyright © 2017 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  19. Speech detection in noise and spatial unmasking in children with simultaneous versus sequential bilateral cochlear implants.

    Science.gov (United States)

    Chadha, Neil K; Papsin, Blake C; Jiwani, Salima; Gordon, Karen A

    2011-09-01

    To measure speech detection in noise performance for children with bilateral cochlear implants (BiCI), to compare performance in children with simultaneous implant versus those with sequential implant, and to compare performance to normal-hearing children. Prospective cohort study. Tertiary academic pediatric center. Children with early-onset bilateral deafness and 2-year BiCI experience, comprising the "sequential" group (>2 yr interimplantation delay, n = 12) and "simultaneous group" (no interimplantation delay, n = 10) and normal-hearing controls (n = 8). Thresholds to speech detection (at 0-degree azimuth) were measured with noise at 0-degree azimuth or ± 90-degree azimuth. Spatial unmasking (SU) as the noise condition changed from 0-degree azimuth to ± 90-degree azimuth and binaural summation advantage (BSA) of 2 over 1 CI. Speech detection in noise was significantly poorer than controls for both BiCI groups (p simultaneous group approached levels found in normal controls (7.2 ± 0.6 versus 8.6 ± 0.6 dB, p > 0.05) and was significantly better than that in the sequential group (3.9 ± 0.4 dB, p simultaneous group but, in the sequential group, was significantly better when noise was moved to the second rather than the first implanted ear (4.8 ± 0.5 versus 3.0 ± 0.4 dB, p sequential group's second rather than first CI. Children with simultaneously implanted BiCI demonstrated an advantage over children with sequential implant by using spatial cues to improve speech detection in noise.

  20. Objective and Subjective Measures of Simultaneous vs Sequential Bilateral Cochlear Implants in Adults: A Randomized Clinical Trial.

    Science.gov (United States)

    Kraaijenga, Véronique J C; Ramakers, Geerte G J; Smulders, Yvette E; van Zon, Alice; Stegeman, Inge; Smit, Adriana L; Stokroos, Robert J; Hendrice, Nadia; Free, Rolien H; Maat, Bert; Frijns, Johan H M; Briaire, Jeroen J; Mylanus, E A M; Huinck, Wendy J; Van Zanten, Gijsbert A; Grolman, Wilko

    2017-09-01

    To date, no randomized clinical trial on the comparison between simultaneous and sequential bilateral cochlear implants (BiCIs) has been performed. To investigate the hearing capabilities and the self-reported benefits of simultaneous BiCIs compared with those of sequential BiCIs. A multicenter randomized clinical trial was conducted between January 12, 2010, and September 2, 2012, at 5 tertiary referral centers among 40 participants eligible for BiCIs. Main inclusion criteria were postlingual severe to profound hearing loss, age 18 to 70 years, and a maximum duration of 10 years without hearing aid use in both ears. Data analysis was conducted from May 24 to June 12, 2016. The simultaneous BiCI group received 2 cochlear implants during 1 surgical procedure. The sequential BiCI group received 2 cochlear implants with an interval of 2 years between implants. First, the results 1 year after receiving simultaneous BiCIs were compared with the results 1 year after receiving sequential BiCIs. Second, the results of 3 years of follow-up for both groups were compared separately. The primary outcome measure was speech intelligibility in noise from straight ahead. Secondary outcome measures were speech intelligibility in noise from spatially separated sources, speech intelligibility in silence, localization capabilities, and self-reported benefits assessed with various hearing and quality of life questionnaires. Nineteen participants were randomized to receive simultaneous BiCIs (11 women and 8 men; median age, 52 years [interquartile range, 36-63 years]), and another 19 participants were randomized to undergo sequential BiCIs (8 women and 11 men; median age, 54 years [interquartile range, 43-64 years]). Three patients did not receive a second cochlear implant and were unavailable for follow-up. Comparable results were found 1 year after simultaneous or sequential BiCIs for speech intelligibility in noise from straight ahead (difference, 0.9 dB [95% CI, -3.1 to 4.4 dB]) and

  1. Clinical and logopaedic results of simultaneous and sequential bilateral implants in children with severe and/or profound bilateral sensorineural hearing loss: A literature review.

    Science.gov (United States)

    López-Torrijo, Manuel; Mengual-Andrés, Santiago; Estellés-Ferrer, Remedios

    2015-06-01

    This article carries out a literature review of the advantages and limitations of the simultaneous bilateral cochlear implantation (SCI) compared to those of the sequential bilateral cochlear implantation (SBCI) and the unilateral cochlear implantation (UCI). The variables analysed in said comparison are: safety and surgical technique, SCI incidence, effectiveness, impact of the inter-implant interval, costs and financing, impact on brain plasticity, impact on speech and language development, main benefits, main disadvantages and concerns, and predictive factors of prognosis. Although the results are not conclusive, all variables analysed seem to point towards observable benefits of SCI in comparison with SBCI or UCI. This tendency should be studied in more depth in multicentre studies with higher methodological rigour, more comprehensive samples and periods and other determining variables (age at the time of implantation, duration and degree of the hearing loss, rehabilitation methodologies used, family involvement, etc.). Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  2. The effect of differential listening experience on the development of expressive and receptive language in children with bilateral cochlear implants.

    Science.gov (United States)

    Hess, Christi; Zettler-Greeley, Cynthia; Godar, Shelly P; Ellis-Weismer, Susan; Litovsky, Ruth Y

    2014-01-01

    Growing evidence suggests that children who are deaf and use cochlear implants (CIs) can communicate effectively using spoken language. Research has reported that age of implantation and length of experience with the CI play an important role in a predicting a child's linguistic development. In recent years, the increase in the number of children receiving bilateral CIs (BiCIs) has led to interest in new variables that may also influence the development of hearing, speech, and language abilities, such as length of bilateral listening experience and the length of time between the implantation of the two CIs. One goal of the present study was to determine how a cohort of children with BiCIs performed on standardized measures of language and nonverbal cognition. This study examined the relationship between performance on language and nonverbal intelligence quotient (IQ) tests and the ages at implantation of the first CI and second CI. This study also examined whether early bilateral activation is related to better language scores. Children with BiCIs (n = 39; ages 4 to 9 years) were tested on two standardized measures, the Test of Language Development and the Leiter International Performance Scale-Revised, to evaluate their expressive/receptive language skills and nonverbal IQ/memory. Hierarchical regression analyses were used to evaluate whether BiCI hearing experience predicts language performance. While large intersubject variability existed, on average, almost all the children with BiCIs scored within or above normal limits on measures of nonverbal cognition. Expressive and receptive language scores were highly variable, less likely to be above the normative mean, and did not correlate with Length of first CI Use, defined as length of auditory experience with one cochlear implant, or Length of second CI Use, defined as length of auditory experience with two cochlear implants. All children in the present study had BiCIs. Most IQ scores were either at or above that

  3. Parenting stress in parents of children with cochlear implants: relationships among parent stress, child language, and unilateral versus bilateral implants.

    Science.gov (United States)

    Sarant, Julia; Garrard, Philippa

    2014-01-01

    Little attention has been focused on stress levels of parents of children with cochlear implants (CIs). This study examined the stress experience of 70 parents of children with CIs by comparing stress levels in this group of parents to those in parents of children without disabilities, identifying primary stressors, examining the relationship between parent stress and child language, and comparing stress in parents of children with bilateral and unilateral CIs. Parents completed a parent stress questionnaire, and the receptive vocabulary and language abilities of the children were evaluated. Results indicated that these parents had a higher incidence of stress than the normative population. Parent stress levels and child language outcomes were negatively correlated. Child behavior and lack of spousal and social support were the prime causes of parent stress. Parents of children with bilateral CIs were significantly less stressed than were parents of children with unilateral CIs.

  4. Cochlear implantation in Mondini dysplasia.

    Science.gov (United States)

    Daneshi, Ahmad; Hassanzadeh, Saeid; Abasalipour, Parvaneh; Emamdjomeh, Hessamaddin; Farhadi, Mohammad

    2003-01-01

    The use of cochlear implantation to treat patients with inner ear malformations such as Mondini dysplasia has been increasingly successful. Until now, conventional hearing aids in these patients have not performed well. Consequently, the hearing problem for patients with this condition has been somewhat improved with the use of cochlear implants. Various results of cochlear implantation have been reported in these patients so far. This is a report of 5 patients with Mondini malformation who have undergone cochlear implant surgery. Copyright 2003 S. Karger AG, Basel

  5. Experiences with bimodal hearing and bilateral cochlear implantation in the elderly

    Directory of Open Access Journals (Sweden)

    E.M. Schedlbauer

    2011-03-01

    Full Text Available With the geriatric population being the fastest growing segment of our society the number of elderly people with different levels of hearing impairments is increasing. According to the German Society of Hearing Impaired there are concerned 37% of the 60-69-year-old and 54% of the over 70-year-old. Furthermore the needs of the elderly are changing with augmented social activity and agility compared to former times: 80 is the new 70. After initial concerns about poor audiologic performance and added peri- and postoperative risks because of comorbidities, cochlear implantation is becoming more and more the method of choice also for postlingually deaf people of higher age. With the demographic shift there can be observed a trend reversal: the proportion of implantees is sliding from the young to the senior and duration of deafness at the time of implantation is declining (Battmer 2010. It is therefore necessary to investigate the impact of cochlear implantation on audiologic performance and quality of life in this growing age group.

  6. COCHLEAR IMPLANTATION PREVALENCE IN ELDERLY

    Directory of Open Access Journals (Sweden)

    A. V. Starokha

    2014-01-01

    Full Text Available Current paper describes an experience of cochlear implantation in elderly. Cochlear implantation has become a widely accepted intervention in the treatment of individuals with severe-to-profound sensorineural hearing loss. Cochlear implants are now accepted as a standard of care to optimize hearing and subsequent speech development in children and adults with deafness. But cochlear implantation affects not only hearing abilities, speech perception and speech production; it also has an outstanding impact on the social life, activities and self-esteem of each patient. The aim of this study was to evaluate the cochlear implantation efficacy in elderly with severe to profound sensorineural hearing loss. There were 5 patients under our observation. Surgery was performed according to traditional posterior tympanotomy and cochleostomy for cochlear implant electrode insertion for all observed patients. The study was conducted in two stages: before speech processor’s activation and 3 months later. Pure tone free field audiometry was performed to each patient to assess the efficiency of cochlear implantation in dynamics. The aim of the study was also to evaluate quality of life in elderly with severe to profound sensorineural hearing loss after unilateral cochlear implantation. Each patient underwent questioning with 36 Item Short Form Health Survey (SF-36. SF-36 is a set of generic, coherent, and easily administered quality-of-life measures. The SF-36 consists of eight scaled scores, which are the weighted sums of the questions in their section. Each scale is directly transformed into a 0-100 scale on the assumption that each question carries equal weight. The eight sections are: physical functioning; physical role functioning; emotional role functioning; vitality; emotional well-being; social role functioning; bodily pain; general health perceptions. Our results demonstrate that cochlear implantation in elderly consistently improved quality of life

  7. Cochlear implants in Waardenburg syndrome.

    Science.gov (United States)

    Cullen, Robert D; Zdanski, Carlton; Roush, Patricia; Brown, Carolyn; Teagle, Holly; Pillsbury, Harold C; Buchman, Craig

    2006-07-01

    Waardenburg syndrome is an autosomal-dominant syndrome characterized by dystopia canthorum, hyperplasia of the eyebrows, heterochromia irides, a white forelock, and sensorineural hearing loss in 20% to 55% of patients. This patient population accounts for approximately 2% of congenitally deaf children. The purpose of this retrospective case review was to describe the outcomes for those children with Waardenburg syndrome who have undergone cochlear implantation. Pediatric cochlear implant recipients with documented evidence of Waardenburg syndrome underwent retrospective case review. All patients received their cochlear implants at the study institution followed by outpatient auditory habilitation. Charts were reviewed for etiology and duration of deafness, age at time of cochlear implantation, perioperative complications, duration of use, and performance outcomes. Results of standard tests batteries for speech perception and production administered as a part of the patients' auditory habilitation were reviewed. Seven patients with Waardenburg syndrome and cochlear implants were identified. The average age at implantation was 37 months (range, 18-64 months) and the average duration of use was 69 months (range, 12-143 months). All of these patients are active users of their devices and perform very well after implantation. There were no major complications in this small group of patients. Children with congenital sensorineural hearing loss without other comorbidities (e.g., developmental delay, inner ear malformations) perform well when they receive cochlear implantation and auditory habilitation. Patients with Waardenburg syndrome can be expected to have above-average performance after cochlear implantation.

  8. Cochlear implants in children implanted in Jordan: A parental overview.

    Science.gov (United States)

    Alkhamra, Rana A

    2015-07-01

    Exploring the perspective of parents on the cochlear implant process in Jordan. Sixty parents of deaf children were surveyed on the information gathering process prior to cochlear implant surgery, and their implant outcome expectations post-surgery. Whether child or parent characteristics may impact parents' post-surgical expectations was explored. Although parents used a variety of information sources when considering a cochlear implant, the ear, nose and throat doctor comprised their major source of information (60%). Parents received a range of information prior to cochlear implant but agreed (93.3%) on the need for a multidisciplinary team approach. Post-surgically, parents' expected major developments in the areas of spoken language (97%), and auditory skills (100%). Receiving education in mainstream schools (92%) was expected too. Parents perceived the cochlear implant decision as the best decision they can make for their child (98.3%). A significant correlation was found between parents contentment with the cochlear implant decision and expecting developments in the area of reading and writing (r=0.7). Child's age at implantation and age at hearing loss diagnosis significantly affected parents' post-implant outcome expectations (pparents agree on the need for a comprehensive multidisciplinary team approach during the different stages of the cochlear implant process. Parents' education about cochlear implants prior to the surgery can affect their post-surgical outcome expectations. The parental perspective presented in this study can help professionals develop better understanding of parents' needs and expectations and henceforth improve their services and support during the different stages of the cochlear implant process. Copyright © 2015. Published by Elsevier Ireland Ltd.

  9. Balance Performance of Deaf Children With and Without Cochlear Implants

    Directory of Open Access Journals (Sweden)

    Amir-Abbas Ebrahimi

    2016-12-01

    Full Text Available  The aim of this study was to compare the static and dynamic balance performance of deaf children with and without cochlear implants. This is a cross-sectional study of 145 school children, aged between 7 and 12 years comprising 85 children with congenital or early acquired bilateral profound sensorineural hearing loss (the hearing loss group and 60 normal hearing aged-matched control counterparts were assessed using the balance subtest of Bruininks-Oseretsky test of Motor Proficiency (BOTMP. The hearing loss group, 50 without cochlear implants (the non-implant group and 35 of them with unilateral cochlear implants (the implant group were recruited from schools for the deaf and normal hearing children (the control group randomly selected from two randomly selected elementary schools of Tehran city. The scores were analyzed using one-way ANOVA. The total score of deaf children especially the implant group were significantly lower than the control group P<0.001. The balance performance of the control group was better than the implant group in all of the items as well as the non-implant group except the fourth tested item (walking forward on a line (P<0.05. The balance score of the implant group was significantly lower than the non-implant group except for the third tested item (standing on the preferred leg on a balance beam with eyes closed. The findings suggested that deaf children, specifically those with cochlear implants are at risk for motor and balance deficits. Thus, vestibular and motor evaluations, as well as interventions to improve balance and motor skills, should be prioritized for this population.

  10. Cadaveric feasibility study of da Vinci Si-assisted cochlear implant with augmented visual navigation for otologic surgery.

    Science.gov (United States)

    Liu, Wen P; Azizian, Mahdi; Sorger, Jonathan; Taylor, Russell H; Reilly, Brian K; Cleary, Kevin; Preciado, Diego

    2014-03-01

    To our knowledge, this is the first reported cadaveric feasibility study of a master-slave-assisted cochlear implant procedure in the otolaryngology-head and neck surgery field using the da Vinci Si system (da Vinci Surgical System; Intuitive Surgical, Inc). We describe the surgical workflow adaptations using a minimally invasive system and image guidance integrating intraoperative cone beam computed tomography through augmented reality. To test the feasibility of da Vinci Si-assisted cochlear implant surgery with augmented reality, with visualization of critical structures and facilitation with precise cochleostomy for electrode insertion. Cadaveric case study of bilateral cochlear implant approaches conducted at Intuitive Surgical Inc, Sunnyvale, California. Bilateral cadaveric mastoidectomies, posterior tympanostomies, and cochleostomies were performed using the da Vinci Si system on a single adult human donor cadaveric specimen. Radiographic confirmation of successful cochleostomies, placement of a phantom cochlear implant wire, and visual confirmation of critical anatomic structures (facial nerve, cochlea, and round window) in augmented stereoendoscopy. With a surgical mean time of 160 minutes per side, complete bilateral cochlear implant procedures were successfully performed with no violation of critical structures, notably the facial nerve, chorda tympani, sigmoid sinus, dura, or ossicles. Augmented reality image overlay of the facial nerve, round window position, and basal turn of the cochlea was precise. Postoperative cone beam computed tomography scans confirmed successful placement of the phantom implant electrode array into the basal turn of the cochlea. To our knowledge, this is the first study in the otolaryngology-head and neck surgery literature examining the use of master-slave-assisted cochleostomy with augmented reality for cochlear implants using the da Vinci Si system. The described system for cochleostomy has the potential to improve the

  11. Follow-up of cochlear implant use in patients who developed bacterial meningitis following cochlear implantation.

    Science.gov (United States)

    Mancini, Patrizia; D'Elia, Chiara; Bosco, Ersilia; De Seta, Elio; Panebianco, Valeria; Vergari, Valeria; Filipo, Roberto

    2008-08-01

    The present study is a long-term follow-up of speech perception outcomes and cochlear implant use in three cases of meningitis that occurred after cochlear implantation. Case series study. Study was performed on three children implanted with different models of Clarion devices, two of them with positioner. Recognition and comprehension were assessed via the Italian adaptation of GASP (TAP) test, and phonetically balanced bi-syllabic words in open-set. High resolution computed tomography scan acquisition was performed to obtain axial coronal and oblique multiplanar reconstructions of the cochlea. Two patients were affected by enlarged cochlear acqueduct and Mondini malformation the first carrying positioner. One patient had a normal cochlea, and the positioner could have been the main cause of bacterial spread. As a consequence of meningitis the child with normal cochlea and the other with enlarged vestibular acqueduct developed cochlear ossification, increased M-level and worsening of hearing outcomes. The child with Mondini malformation developed facial nerve stimulation. Contralateral implantation was performed in the first two patients. Bacterial meningitis occurring after cochlear implantation may induce cochlear ossification, facial nerve stimulation, and permanent or temporary loss of implant use. Planned follow-up with high resolution computed tomography and evaluation of M-levels could be useful prognostic tools in the management of these patients.

  12. Audiovisual segregation in cochlear implant users.

    Directory of Open Access Journals (Sweden)

    Simon Landry

    Full Text Available It has traditionally been assumed that cochlear implant users de facto perform atypically in audiovisual tasks. However, a recent study that combined an auditory task with visual distractors suggests that only those cochlear implant users that are not proficient at recognizing speech sounds might show abnormal audiovisual interactions. The present study aims at reinforcing this notion by investigating the audiovisual segregation abilities of cochlear implant users in a visual task with auditory distractors. Speechreading was assessed in two groups of cochlear implant users (proficient and non-proficient at sound recognition, as well as in normal controls. A visual speech recognition task (i.e. speechreading was administered either in silence or in combination with three types of auditory distractors: i noise ii reverse speech sound and iii non-altered speech sound. Cochlear implant users proficient at speech recognition performed like normal controls in all conditions, whereas non-proficient users showed significantly different audiovisual segregation patterns in both speech conditions. These results confirm that normal-like audiovisual segregation is possible in highly skilled cochlear implant users and, consequently, that proficient and non-proficient CI users cannot be lumped into a single group. This important feature must be taken into account in further studies of audiovisual interactions in cochlear implant users.

  13. A case of improved hearing with cochlear implantation in Gaucher disease type 1.

    Science.gov (United States)

    Endo, Shiori; Mizuta, Kunihiro; Yamatodani, Takashi; Nakanishi, Hiroshi; Hosokawa, Kumiko; Misawa, Kiyoshi; Hosokawa, Seiji; Mineta, Hiroyuki

    2018-06-01

    Gaucher disease is a lysosomal storage disorder that is caused by congenital defective function of the enzyme glucocerebrosidase. Glucocerebroside that is not hydrolyzed by glucocerebrosidase mainly accumulates in the reticular tissue. We describe a Japanese boy with Gaucher disease type 1 who developed bilateral profound sensorineural hearing loss within approximately 4years. We performed cochlear implantation initially on his right ear and again on his left ear 5 months later. The cochlear implants were successfully utilized with a speech discrimination score of 95% on a Japanese sentence recognition test. There are many reports of central hearing loss in Gaucher disease type 2 or 3. However, to the best of our knowledge, this is the first report of profound inner ear hearing loss with Gaucher disease. It also appears to be the first record of cochlear implantation for Gaucher disease. Cochlear implants may be useful for sensorineural hearing loss in patients with Gaucher disease without neurological symptoms other than hearing loss. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Speech Perception Outcomes after Cochlear Implantation in Children with GJB2/DFNB1 associated Deafness

    Directory of Open Access Journals (Sweden)

    Marina Davcheva-Chakar

    2014-03-01

    Full Text Available Background: Cochlear implants (CI for the rehabilitation of patients with profound or total bilateral sensorineural hypoacusis represent the initial use of electrical fields to provide audibility in cases where the use of sound amplifiers does not provide satisfactory results. Aims: To compare speech perception performance after cochlear implantation in children with connexin 26-associated deafness with that of a control group of children with deafness of unknown etiology. Study Design: Retrospective comparative study. Methods: During the period from 2006 to , cochlear implantation was performed on 26 children. Eighteen of these children had undergone genetic tests for mutation of the Gap Junction Protein Beta 2 (GJB2 gene. Bi-allelic GJB2 mutations were confirmed in 7 out of 18 examined children. In order to confirm whether genetic factors have influence on speech perception after cochlear implantation, we compared the post-implantation speech performance of seven children with mutations of the GBJ2 (connexin 26 gene with seven other children who had the wild type version of this particular gene. The latter were carefully matched according to the age at cochlear implantation. Speech perception performance was measured before cochlear implantation, and one and two years after implantation. All the patients were arranged in line with the appropriate speech perception category (SPC. Non-parametric tests, Friedman ANOVA and Mann-Whitney’s U test were used for statistical analysis. Results: Both groups showed similar improvements in speech perception scores after cochlear implantation. Statistical analysis did not confirm significant differences between the groups 12 and 24 months after cochlear implantation. Conclusion: The results obtained in this study showed an absence of apparent distinctions in the scores of speech perception between the two examined groups and therefore might have significant implications in selecting prognostic indicators

  15. Development of Sound Localization Strategies in Children with Bilateral Cochlear Implants.

    Directory of Open Access Journals (Sweden)

    Yi Zheng

    Full Text Available Localizing sounds in our environment is one of the fundamental perceptual abilities that enable humans to communicate, and to remain safe. Because the acoustic cues necessary for computing source locations consist of differences between the two ears in signal intensity and arrival time, sound localization is fairly poor when a single ear is available. In adults who become deaf and are fitted with cochlear implants (CIs sound localization is known to improve when bilateral CIs (BiCIs are used compared to when a single CI is used. The aim of the present study was to investigate the emergence of spatial hearing sensitivity in children who use BiCIs, with a particular focus on the development of behavioral localization patterns when stimuli are presented in free-field horizontal acoustic space. A new analysis was implemented to quantify patterns observed in children for mapping acoustic space to a spatially relevant perceptual representation. Children with normal hearing were found to distribute their responses in a manner that demonstrated high spatial sensitivity. In contrast, children with BiCIs tended to classify sound source locations to the left and right; with increased bilateral hearing experience, they developed a perceptual map of space that was better aligned with the acoustic space. The results indicate experience-dependent refinement of spatial hearing skills in children with CIs. Localization strategies appear to undergo transitions from sound source categorization strategies to more fine-grained location identification strategies. This may provide evidence for neural plasticity, with implications for training of spatial hearing ability in CI users.

  16. Cochlear implants and medical tourism.

    Science.gov (United States)

    McKinnon, Brian J; Bhatt, Nishant

    2010-09-01

    To compare the costs of medical tourism in cochlear implant surgery performed in India as compared to the United States. In addition, the cost savings of obtaining cochlear implant surgery in India were compare d to those of other surgical interventions obtained as a medical tourist. Searches were conducted on Medline and Google using the search terms: 'medical tourism', 'medical offshoring', 'medical outsourcing', 'cochlear implants' and 'cochlear implantation'. The information regarding cost of medical treatment was obtained from personal communication with individuals familiar with India's cochlear implantation medical tourism industry. The range of cost depended on length of stay as well as the device chosen. Generally the cost, inclusive of travel, surgery and device, was in the range of $21,000-30,000, as compared to a cost range of $40,000-$60,000 in the US. With the escalating cost of healthcare in the United States, it is not surprising that some patients would seek to obtain surgical care overseas at a fraction of the cost. Participants in medical tourism often have financial resources, but lack health insurance coverage. While cardiovascular and orthopedic surgery performed outside the United States in India at centers that cater to medical tourists are often performed at one-quarter to one-third of the cost that would have been paid in the United States, the cost differential for cochlear implants is not nearly as favorable.

  17. Trends in Cochlear Implants

    OpenAIRE

    Zeng, Fan-Gang

    2004-01-01

    More than 60,000 people worldwide use cochlear implants as a means to restore functional hearing. Although individual performance variability is still high, an average implant user can talk on the phone in a quiet environment. Cochlear-implant research has also matured as a field, as evidenced by the exponential growth in both the patient population and scientific publication. The present report examines current issues related to audiologic, clinical, engineering, anatomic, and physiologic as...

  18. Parental expectations and outcomes of pediatric cochlear implantation.

    Science.gov (United States)

    Piazza, Elizabeth; Kandathil, Cherian; Carron, Jeffrey D

    2009-10-01

    Cochlear implants have been used with increasing frequency over the past twenty years, including very young patients. To determine if parents are satisfied with their children's performance after cochlear implantation. Survey mailed to parents of children receiving cochlear implants. 31 questionnaires were returned out of 69 mailed (45 %). The vast majority of responding parents felt that their children benefited substantially from cochlear implant surgery. Cochlear implantation is effective in helping children develop auditory-oral communication skills. Access to auditory/oral communication programs in this state remains an obstacle in postoperative habilitation.

  19. Importance of cochlear health for implant function.

    Science.gov (United States)

    Pfingst, Bryan E; Zhou, Ning; Colesa, Deborah J; Watts, Melissa M; Strahl, Stefan B; Garadat, Soha N; Schvartz-Leyzac, Kara C; Budenz, Cameron L; Raphael, Yehoash; Zwolan, Teresa A

    2015-04-01

    Amazing progress has been made in providing useful hearing to hearing-impaired individuals using cochlear implants, but challenges remain. One such challenge is understanding the effects of partial degeneration of the auditory nerve, the target of cochlear implant stimulation. Here we review studies from our human and animal laboratories aimed at characterizing the health of the implanted cochlea and the auditory nerve. We use the data on cochlear and neural health to guide rehabilitation strategies. The data also motivate the development of tissue-engineering procedures to preserve or build a healthy cochlea and improve performance obtained by cochlear implant recipients or eventually replace the need for a cochlear implant. This article is part of a Special Issue entitled . Copyright © 2014 Elsevier B.V. All rights reserved.

  20. CT evaluation of preoperative cochlear implantation cochlear implantation

    International Nuclear Information System (INIS)

    Tan Xiuzhong; Zhong Lansheng; Lan Bowen; Huang Yaosheng; Du Baowen; Zhu Jian

    2004-01-01

    Objective: To evaluate CT scan as a preoperative evaluation for cochlear implantation candidates. Methods: Axial high-resolution temporal bone CT and three-dimensional reconstruction of inner ear were performed in 93 patients with sensorineural hearing loss. results: Among 81 patients with congenital sensorineural deafness, Mondini malformation was seen in 7 case (13 ears); large vestibular aqueduct syndrome (LVAS) was revealed in 5 cases (8 ears); and inner ear ossification was found in 1 case (2 ears). In 1 case (2 ears) of inner ear fibrosis, reduced cochlear signal was noted on MRI but no unremarkable findings was shown on CT scan, however, in the operation, the device could not inserted into the basal circle of the cochlea, due to fibrous obliteration. In 12 patients with post-speech deafness, chronic suppurative tympanitis was seen in 2 cases (4 ears), and inner ear ossification was revealed in 1 case (2 ears). Conclusion: CT plays an indispensable role in the pre-operative evaluation of cochlear implantation. T 2 -weighted FSE-MRI of the inner ear is a useful complementary to CT scan. (authors)

  1. Age at implantation and auditory memory in cochlear implanted children.

    Science.gov (United States)

    Mikic, B; Miric, D; Nikolic-Mikic, M; Ostojic, S; Asanovic, M

    2014-05-01

    Early cochlear implantation, before the age of 3 years, provides the best outcome regarding listening, speech, cognition an memory due to maximal central nervous system plasticity. Intensive postoperative training improves not only auditory performance and language, but affects auditory memory as well. The aim of this study was to discover if the age at implantation affects auditory memory function in cochlear implanted children. A total of 50 cochlear implanted children aged 4 to 8 years were enrolled in this study: early implanted (1-3y) n = 27 and late implanted (4-6y) n = 23. Two types of memory tests were used: Immediate Verbal Memory Test and Forward and Backward Digit Span Test. Early implanted children performed better on both verbal and numeric tasks of auditory memory. The difference was statistically significant, especially on the complex tasks. Early cochlear implantation, before the age of 3 years, significantly improve auditory memory and contribute to better cognitive and education outcomes.

  2. Congenital malformations of the ear and cochlear implantation in children: review and temporal bone report of common cavity.

    Science.gov (United States)

    Graham, J M; Phelps, P D; Michaels, L

    2000-01-01

    The objective of this review is to analyze aspects of congenital malformation of the ear in relation to cochlear implantation in children. Having briefly described the in utero development of the ear and the classification of types of external, middle and inner ear malformation, five practical aspects of these malformations are discussed. It seems likely that the combination of bilateral profound sensorineural deafness with bilateral microtia severe enough to make a surgical approach to the cochlea difficult will be extremely uncommon. No such cases have been reported, although Klippel-Feil deformity seems the syndrome most likely to produce this set of circumstances. Abnormalities in the intratympanic course of the facial nerve have been associated with cochlear malformation, emphasizing the benefit of intra-operative facial nerve monitoring, and a technique suggested for safely avoiding an abnormally placed nerve. Fistulae of cerebrospinal fluid (CSF) and perilymph can complicate surgery and are relatively common in common cavity and Mondini malformations. Strategies for facilitating surgery in the presence of 'gushers', for measuring the pressure of a gusher and for placement of the cochlear implant electrode array are reviewed, with reports of fluctuating levels of electric current when implants lie in dysplastic cochleas. The relationship of implant performance to VIIIth nerve tissue in malformed cochleas is discussed, with a description of the histological findings in a common cavity cochlea. Techniques for identifying the absence of the cochlear nerve are reviewed. Stimulation of the facial nerve by cochlear implants has been described in cases of congenital malformation of the labyrinth but is relatively uncommon. Case reports of the benefit received by implanted children with congenital cochlear malformation have appeared since 1988. Most cases reported have not yet been followed for long enough to establish a clear picture of the outcome following

  3. Auditory cortical activation and plasticity after cochlear implantation measured by PET using fluorodeoxyglucose.

    Science.gov (United States)

    Łukaszewicz-Moszyńska, Zuzanna; Lachowska, Magdalena; Niemczyk, Kazimierz

    2014-01-01

    The purpose of this study was to evaluate possible relationships between duration of cochlear implant use and results of positron emission tomography (PET) measurements in the temporal lobes performed while subjects listened to speech stimuli. Other aspects investigated were whether implantation side impacts significantly on cortical representations of functions related to understanding speech (ipsi- or contralateral to the implanted side) and whether any correlation exists between cortical activation and speech therapy results. Objective cortical responses to acoustic stimulation were measured, using PET, in nine cochlear implant patients (age range: 15 to 50 years). All the patients suffered from bilateral deafness, were right-handed, and had no additional neurological deficits. They underwent PET imaging three times: immediately after the first fitting of the speech processor (activation of the cochlear implant), and one and two years later. A tendency towards increasing levels of activation in areas of the primary and secondary auditory cortex on the left side of the brain was observed. There was no clear effect of the side of implantation (left or right) on the degree of cortical activation in the temporal lobe. However, the PET results showed a correlation between degree of cortical activation and speech therapy results.

  4. Correlation between subjective and objective hearing tests after unilateral and bilateral cochlear implantation

    NARCIS (Netherlands)

    Ramakers, Geerte G.J.; Smulders, Yvette E.; Van Zon, Alice; van Zanten, Gijsbert A.; Grolman, Wilko; Stegeman, Inge

    2017-01-01

    Background: There are many methods for assessing hearing performance after cochlear implantation. Standard evaluations often encompass objective hearing tests only, while patients' subjective experiences gain importance in today's healthcare. The aim of the current study was to analyze the

  5. Benefits and detriments of unilateral cochlear implant use on bilateral auditory development in children who are deaf

    Directory of Open Access Journals (Sweden)

    Karen A. Gordon

    2013-10-01

    Full Text Available We have explored both the benefits and detriments of providing electrical input through a cochlear implant in one ear to the auditory system of young children. A cochlear implant delivers electrical pulses to stimulate the auditory nerve, providing children who are deaf with access to sound. The goals of implantation are to restrict reorganization of the deprived immature auditory brain and promote development of hearing and spoken language. It is clear that limiting the duration of deprivation is a key factor. Additional considerations are the onset, etiology, and use of residual hearing as each of these can have unique effects on auditory development in the pre-implant period. New findings show that many children receiving unilateral cochlear implants are developing mature-like brainstem and thalamo-cortical responses to sound with long term use despite these sources of variability; however, there remain considerable abnormalities in cortical function. The most apparent, determined by implanting the other ear and measuring responses to acute stimulation, is a loss of normal cortical response from the deprived ear. Recent data reveal that this can be avoided in children by early implantation of both ears simultaneously or with limited delay. We conclude that auditory development requires input early in development and from both ears.

  6. Assessment of Cochlear Function during Cochlear Implantation by Extra- and Intracochlear Electrocochleography

    OpenAIRE

    Dalbert, Adrian; Pfiffner, Flurin; Hoesli, Marco; Koka, Kanthaiah; Veraguth, Dorothe; Roosli, Christof; Huber, Alexander

    2018-01-01

    Objective: The aims of this study were: (1) To investigate the correlation between electrophysiological changes during cochlear implantation and postoperative hearing loss, and (2) to detect the time points that electrophysiological changes occur during cochlear implantation. Material and Methods: Extra- and intracochlear electrocochleography (ECoG) were used to detect electrophysiological changes during cochlear implantation. Extracochlear ECoG recordings were conducted through a needle elec...

  7. Cochlear Implants

    Science.gov (United States)

    ... NIDCD A cochlear implant is a small, complex electronic device that can help to provide a sense ... Hearing Aids Retinitis Pigmentosa - National Eye Institute Telecommunications Relay Services Usher Syndrome Your Baby's Hearing Screening News ...

  8. What Does Music Sound Like for a Cochlear Implant User?

    Science.gov (United States)

    Jiam, Nicole T; Caldwell, Meredith T; Limb, Charles J

    2017-09-01

    Cochlear implant research and product development over the past 40 years have been heavily focused on speech comprehension with little emphasis on music listening and enjoyment. The relatively little understanding of how music sounds in a cochlear implant user stands in stark contrast to the overall degree of importance the public places on music and quality of life. The purpose of this article is to describe what music sounds like to cochlear implant users, using a combination of existing research studies and listener descriptions. We examined the published literature on music perception in cochlear implant users, particularly postlingual cochlear implant users, with an emphasis on the primary elements of music and recorded music. Additionally, we administered an informal survey to cochlear implant users to gather first-hand descriptions of music listening experience and satisfaction from the cochlear implant population. Limitations in cochlear implant technology lead to a music listening experience that is significantly distorted compared with that of normal hearing listeners. On the basis of many studies and sources, we describe how music is frequently perceived as out-of-tune, dissonant, indistinct, emotionless, and weak in bass frequencies, especially for postlingual cochlear implant users-which may in part explain why music enjoyment and participation levels are lower after implantation. Additionally, cochlear implant users report difficulty in specific musical contexts based on factors including but not limited to genre, presence of lyrics, timbres (woodwinds, brass, instrument families), and complexity of the perceived music. Future research and cochlear implant development should target these areas as parameters for improvement in cochlear implant-mediated music perception.

  9. [Multi-channel cochlear implants in patients with Mondini malformation].

    Science.gov (United States)

    Li, Yong-xin; Han, De-min; Zhao, Xiao-tian; Chen, Xue-qing; Kong, Ying; Zheng, Jun; Liu, Bo; Liu, Sha; Mo, Ling-yan; Zhang, Hua; Wang, Shuo

    2004-02-01

    To describe clinical experiences with multi-channel cochlear implantation in patients with Mondini malformation. Among 300 patients who received multi-channel cochlear implants from 1996 to 2002 in Beijing Tongren Hospital, 15 patients were diagnosed with Mondini malformation. A retrospective analysis was performed dealing with the surgical techniques, mapping and rehabilitations characteristics after surgery. 15 patients with normal cochlear structure are consider as control group. Gusher is found more common than the normal cochlear implantation, most of them are serious. The electrodes are inserted in the "cochleostomy" in full length of 13 Patients, 2 pairs of electrodes remains outside of "cochleostomy" in 2 patients. No serious complications occurred after implantation. All patients have auditory sensations. The impedance of the electrodes, the T level, C level and the hearing threshold are similar with the normal cochlear implantation group. The results have no significant difference in compare with normal cochlear group(P > 0.05). Multi-channel cochlear implantation could be performed safely in patients with Mondini malformation. The primary outcome for patients with Mondini malformation are similar to those with normal cochlear structure following the multi-channel cochlear implantation.

  10. [The development of musicality in children after cochlear implantation].

    Science.gov (United States)

    Zheng, Yan; Liu, Bo; Dong, Ruijuan; Xu, Tianqiu; Chen, Jing; Chen, Xuejing; Zhong, Yan; Meng, Chao; Wang, Hong; Chen, Xueqing

    2014-08-01

    The purpose of this study is to analyze the development of musicality in children after cochlear implantation, and provide a clinical database for the evaluation of their musicality. Twenty-six children with cochlear implants (CI group) participated in this research. They received cochlear implants at the age of 11 to 68 months with a mean of 35.6 months. Seventy-six infants as a control group aged from 1 to 24 months with a mean of 6.1 months participated in this study, whose hearing were considered normal by passing the case history collection, high-risk registers for hearing loss and hearing screening using DPOAE. The music and young children with CIs: Musicality Rating Scale was used to evaluate their musicality. The evaluation was performed before cochlear implantation and 1, 3, 6, 9, 12, 24 months after cochlear implantation for children with cochlear implants. The evaluation was also performed at 1, 3, 6, 9, 12, 24 months for children with normal hearing. The mean scores of musicality showed significant improvements with time of CI use for CI group (Pmusicality also showed significant improvements with time for control group (P0.05). Significant difference was noted between the two groups at 24 months (Pmusicality of children with cochlear implants improved significantly with time after cochlear implantation. The most rapid growth was found in the first year after cochlear implantation.

  11. Remote programming of cochlear implants: a telecommunications model.

    Science.gov (United States)

    McElveen, John T; Blackburn, Erin L; Green, J Douglas; McLear, Patrick W; Thimsen, Donald J; Wilson, Blake S

    2010-09-01

    Evaluate the effectiveness of remote programming for cochlear implants. Retrospective review of the cochlear implant performance for patients who had undergone mapping and programming of their cochlear implant via remote connection through the Internet. Postoperative Hearing in Noise Test and Consonant/Nucleus/Consonant word scores for 7 patients who had undergone remote mapping and programming of their cochlear implant were compared with the mean scores of 7 patients who had been programmed by the same audiologist over a 12-month period. Times required for remote and direct programming were also compared. The quality of the Internet connection was assessed using standardized measures. Remote programming was performed via a virtual private network with a separate software program used for video and audio linkage. All 7 patients were programmed successfully via remote connectivity. No untoward patient experiences were encountered. No statistically significant differences could be found in comparing postoperative Hearing in Noise Test and Consonant/Nucleus/Consonant word scores for patients who had undergone remote programming versus a similar group of patients who had their cochlear implant programmed directly. Remote programming did not require a significantly longer programming time for the audiologist with these 7 patients. Remote programming of a cochlear implant can be performed safely without any deterioration in the quality of the programming. This ability to remotely program cochlear implant patients gives the potential to extend cochlear implantation to underserved areas in the United States and elsewhere.

  12. Benefits of simultaneous bilateral cochlear implantation on verbal reasoning skills in prelingually deaf children

    NARCIS (Netherlands)

    Jacobs, Evi; Langereis, Margreet C.; Frijns, Johan H. M.; Free, Rolien H.; Goedegebure, Andre; Smits, Cas; Stokroos, Robert J.; Ariens-Meijer, Saskia A. M.; Mylanus, Emmanuel A. M.; Vermeulen, Anneke M.

    2016-01-01

    Background: Impaired auditory speech perception abilities in deaf children with hearing aids compromised their verbal intelligence enormously. The availability of unilateral cochlear implantation (Cl) auditory speech perception and spoken vocabulary enabled them to reach near ageappropriate levels.

  13. Benefits of simultaneous bilateral cochlear implantation on verbal reasoning skills in prelingually deaf children

    NARCIS (Netherlands)

    Jacobs, E.; Langereis, M.C.; Frijns, J.H.; Free, R.H.; Goedegebure, A.; Smits, C.; Stokroos, R.J.; Ariens-Meijer, S.A.; Mylanus, E.A.M.; Vermeulen, A.M.J.

    2016-01-01

    BACKGROUND: Impaired auditory speech perception abilities in deaf children with hearing aids compromised their verbal intelligence enormously. The availability of unilateral cochlear implantation (CI) auditory speech perception and spoken vocabulary enabled them to reach near ageappropriate levels.

  14. Use of data mining to predict significant factors and benefits of bilateral cochlear implantation.

    Science.gov (United States)

    Ramos-Miguel, Angel; Perez-Zaballos, Teresa; Perez, Daniel; Falconb, Juan Carlos; Ramosb, Angel

    2015-11-01

    Data mining (DM) is a technique used to discover pattern and knowledge from a big amount of data. It uses artificial intelligence, automatic learning, statistics, databases, etc. In this study, DM was successfully used as a predictive tool to assess disyllabic speech test performance in bilateral implanted patients with a success rate above 90%. 60 bilateral sequentially implanted adult patients were included in the study. The DM algorithms developed found correlations between unilateral medical records and Audiological test results and bilateral performance by establishing relevant variables based on two DM techniques: the classifier and the estimation. The nearest neighbor algorithm was implemented in the first case, and the linear regression in the second. The results showed that patients with unilateral disyllabic test results below 70% benefited the most from a bilateral implantation. Finally, it was observed that its benefits decrease as the inter-implant time increases.

  15. [Cochlear implant treatment in Germany].

    Science.gov (United States)

    Jacob, R; Stelzig, Y

    2013-01-01

    Restoration of impaired auditory function through cochlear implant is possible, with high reliably and great success. Nevertheless, there are regular disputes between patients and insurance companies due to high costs. In Germany, approx. 1.9 Mio. people are severely hearing impaired. It can be estimated that for adequate hearing rehabilitation about 30,000 cochlear implants/year are necessary. Currently, less than 10% of those affected are offered cochlear implant. A handicap is defined if there is deviation from normal hearing for more than 6 months. This sets a time frame for the supply with cochlear implant after sudden deafness. The professional code requires to advice all medical options to a person seeking help for hearing loss. This includes benefit-risk consideration. At this point, the economic aspect plays no role. The indication for medical treatment is only subject to the treating physician and should not be modified by non-physicians or organizations. It should be noted that a supply of hearing aids is qualitatively different to the help from a cochlear implant, which provides a restoration of lost function. In social law (SGB V and IX) doctors are requested to advise and recommend all measures which contribute to normal hearing (both sides). This indicates that doctors may be prosecuted for not offering help when medically possible, just because health insurance employees did not approve the cost balance. The current situation, with insufficient medical care for the hearing impaired, needs clarifying. To do this, patients, health insurance companies, the political institutions, legislation and professional societies need to accept their responsibilities.

  16. Evaluating cochlear implant trauma to the scala vestibuli.

    Science.gov (United States)

    Adunka, O; Kiefer, J; Unkelbach, M H; Radeloff, A; Gstoettner, W

    2005-04-01

    Placement of cochlear implant electrodes into the scala vestibuli may be intentional, e.g. in case of blocked scala tympani or unintentional as a result of trauma to the basilar membrane or erroneous location of the cochieostomy. The aim of this study was to evaluate the morphological consequences and cochlear trauma after implantation of different cochlear implant electrode arrays in the scala vestibuli. Human temporal bone study with histological and radiological evaluation. Twelve human cadaver temporal bones were implanted with different cochlear implant electrodes. Implanted bones were processed using a special method to section undecalcified bone. Cochlear trauma and intracochlear positions. All implanted electrodes were implanted into the scala vestibuli using a special approach that allows direct scala vestibuli insertions. Fractures of the osseous spiral lamina were evaluated in some bones in the basal cochlear regions. In most electrodes, delicate structures of the organ of Corti were left intact, however, Reissner's membrane was destroyed in all specimens and the electrode lay upon the tectorial membrane. In some bones the organ of Corti was destroyed. Scala vestibuli insertions did not cause severe trauma to osseous or neural structures, thus preserving the basis for electrostimulation of the cochlea. However, destruction of Reissner's membrane and impact on the Organ of Corti can be assumed to destroy residual hearing.

  17. Tinnitus and Sleep Difficulties After Cochlear Implantation.

    Science.gov (United States)

    Pierzycki, Robert H; Edmondson-Jones, Mark; Dawes, Piers; Munro, Kevin J; Moore, David R; Kitterick, Pádraig T

    To estimate and compare the prevalence of and associations between tinnitus and sleep difficulties in a sample of UK adult cochlear implant users and those identified as potential candidates for cochlear implantation. The study was conducted using the UK Biobank resource, a population-based cohort of 40- to 69-year olds. Self-report data on hearing, tinnitus, sleep difficulties, and demographic variables were collected from cochlear implant users (n = 194) and individuals identified as potential candidates for cochlear implantation (n = 211). These "candidates" were selected based on (i) impaired hearing sensitivity, inferred from self-reported hearing aid use and (ii) impaired hearing function, inferred from an inability to report words accurately at negative signal to noise ratios on an unaided closed-set test of speech perception. Data on tinnitus (presence, persistence, and related distress) and on sleep difficulties were analyzed using logistic regression models controlling for gender, age, deprivation, and neuroticism. The prevalence of tinnitus was similar among implant users (50%) and candidates (52%; p = 0.39). However, implant users were less likely to report that their tinnitus was distressing at its worst (41%) compared with candidates (63%; p = 0.02). The logistic regression model suggested that this difference between the two groups could be explained by the fact that tinnitus was less persistent in implant users (46%) compared with candidates (72%; p reported difficulties with sleep were similar among implant users (75%) and candidates (82%; p = 0.28), but participants with tinnitus were more likely to report sleep difficulties than those without (p explanation is supported by the similar prevalence of sleep problems among implant users and potential candidates for cochlear implantation, despite differences between the groups in tinnitus persistence and related emotional distress. Cochlear implantation may therefore not be an appropriate intervention

  18. Deafblind People's Experiences of Cochlear Implantation

    Science.gov (United States)

    Soper, Janet

    2006-01-01

    Cochlear implants are electronic devices that create the sensation of hearing in those who cannot obtain any benefit from conventional hearing aids. This article examines the experience of cochlear implantation in a select group of individuals with acquired deafblindness, focusing on three key themes: access to communication, information and…

  19. Efter cochlear implant

    DEFF Research Database (Denmark)

    Højen, Anders

    Dit barn har netop fået et cochlear implant. Hvad nu? Skal barnet fokusere udelukkende på at lære talt sprog, eller skal det også lære/fortsætte med tegnsprog eller støttetegn? Det er et vanskeligt spørgsmål, og før valget foretages, er det vigtigt at vurdere hvilke konsekvenser valget har, dels...... for den sproglige udvikling isoleret set, og dels for barnets udvikling ud fra en helhedsbetragtning. Dette indlæg fokuserer på, hvilke forventninger man kan have til cochlear implant-brugeres sproglige udvikling med talt sprog alene, hhv. med to sprog (tale og tegn). Disse forventninger er baseret på...

  20. Across-frequency combination of interaural time difference in bilateral cochlear implant listeners

    Directory of Open Access Journals (Sweden)

    Antje eIhlefeld

    2014-03-01

    Full Text Available The current study examined how cochlear implant (CI listeners combine temporally interleaved envelope-ITD information across two sites of stimulation. When two cochlear sites jointly transmit ITD information, one possibility is that CI listeners can extract the most reliable ITD cues available. As a result, ITD sensitivity would be sustained or enhanced compared to single-site stimulation. Alternatively, mutual interference across multiple sites of ITD stimulation could worsen dual-site performance compared to listening to the better of two electrode pairs. Two experiments used direct stimulation to examine how CI users can integrate ITDs across two pairs of electrodes. Experiment 1 tested ITD discrimination for two stimulation sites using 100-Hz sinusoidally modulated 1000-pps-carrier pulse trains. Experiment 2 used the same stimuli ramped with 100 ms windows, as a control condition with minimized onset cues. For all stimuli, performance improved monotonically with increasing modulation depth. Results show that when CI listeners are stimulated with electrode pairs at two cochlear sites, sensitivity to ITDs was similar to that seen when only the electrode pair with better sensitivity was activated. None of the listeners showed a decrement in performance from the worse electrode pair. This could be achieved either by listening to the better electrode pair or by truly integrating the information across cochlear sites.

  1. Pain-only complaint about cochlear implant device: A five-patient pediatric experience.

    Science.gov (United States)

    Todd, Norman Wendell; Fainberg, Jolie C; Ukatu, CeIsha Chinwe; Venable, Claudia Y; Segel, Phil

    2015-09-01

    To present the case histories and management of five pediatric patients who experienced pain at the receiver-stimulator site, but no other indication that the device was failing. Patients were from a sole-surgeon pediatric practice (600 + implant surgeries before June 2013; about even proportions of Advanced Bionics, Cochlear Corporation, and MED-EL devices). The University Institutional Review Board-approved review of sole-surgeon pediatric case series. The onset of pain ranged from 2 to 16 years post implantation. Pain, not amenable to conventional medical therapy, was present regardless of whether or not the external appliance was 'on', or even being worn on the head. Four of the five patients were bilaterally implanted, but pain was only at one receiver-stimulator package. Clinical management ultimately included revision surgery in all five cases, with immediate resolution of the pain in four. For those four, the replacement cochlear implant (CI) performed well; the other patient fears pain if her replacement device is used, but continues enjoying her contralateral implant. At analysis by the company, two of five explanted devices exhibited problems: loss of hermeticity; insulation failure. Though infrequently reported, pain-only complaint by a CI user is a challenging dilemma. Pain may be the sole clinical manifestation of cochlear implant device failure. We offer a flowchart for the care of CI patients with pain, encourage a worldwide registry of such cases, and offer ideas to try to understand better the problem.

  2. Prevention and management of cochlear implant infections.

    Science.gov (United States)

    Gluth, Michael B; Singh, Rajesh; Atlas, Marcus D

    2011-11-01

    Understanding the issues of infection related to an implantable medical device is crucial to all cochlear implant teams. Furthermore, given the risk of central nervous system complications and the relatively high quantity of underlying resource investment associated with cochlear implantation, the stakes of infection are high. The optimal strategies to prevent and manage such infections are still evolving as good-quality prospective data to guide such management decisions are not yet abundant within the medical literature and many recommendations are based on retrospective reviews or anecdotal evidence. We will outline a general strategy to deal with cochlear implant-related infection based on both the authors' experience and the published literature.

  3. Bilateral versus unilateral cochlear implants in children: a study of spoken language outcomes.

    Science.gov (United States)

    Sarant, Julia; Harris, David; Bennet, Lisa; Bant, Sharyn

    2014-01-01

    Although it has been established that bilateral cochlear implants (CIs) offer additional speech perception and localization benefits to many children with severe to profound hearing loss, whether these improved perceptual abilities facilitate significantly better language development has not yet been clearly established. The aims of this study were to compare language abilities of children having unilateral and bilateral CIs to quantify the rate of any improvement in language attributable to bilateral CIs and to document other predictors of language development in children with CIs. The receptive vocabulary and language development of 91 children was assessed when they were aged either 5 or 8 years old by using the Peabody Picture Vocabulary Test (fourth edition), and either the Preschool Language Scales (fourth edition) or the Clinical Evaluation of Language Fundamentals (fourth edition), respectively. Cognitive ability, parent involvement in children's intervention or education programs, and family reading habits were also evaluated. Language outcomes were examined by using linear regression analyses. The influence of elements of parenting style, child characteristics, and family background as predictors of outcomes were examined. Children using bilateral CIs achieved significantly better vocabulary outcomes and significantly higher scores on the Core and Expressive Language subscales of the Clinical Evaluation of Language Fundamentals (fourth edition) than did comparable children with unilateral CIs. Scores on the Preschool Language Scales (fourth edition) did not differ significantly between children with unilateral and bilateral CIs. Bilateral CI use was found to predict significantly faster rates of vocabulary and language development than unilateral CI use; the magnitude of this effect was moderated by child age at activation of the bilateral CI. In terms of parenting style, high levels of parental involvement, low amounts of screen time, and more time spent

  4. Bilateral Versus Unilateral Cochlear Implants in Children: A Study of Spoken Language Outcomes

    Science.gov (United States)

    Harris, David; Bennet, Lisa; Bant, Sharyn

    2014-01-01

    Objectives: Although it has been established that bilateral cochlear implants (CIs) offer additional speech perception and localization benefits to many children with severe to profound hearing loss, whether these improved perceptual abilities facilitate significantly better language development has not yet been clearly established. The aims of this study were to compare language abilities of children having unilateral and bilateral CIs to quantify the rate of any improvement in language attributable to bilateral CIs and to document other predictors of language development in children with CIs. Design: The receptive vocabulary and language development of 91 children was assessed when they were aged either 5 or 8 years old by using the Peabody Picture Vocabulary Test (fourth edition), and either the Preschool Language Scales (fourth edition) or the Clinical Evaluation of Language Fundamentals (fourth edition), respectively. Cognitive ability, parent involvement in children’s intervention or education programs, and family reading habits were also evaluated. Language outcomes were examined by using linear regression analyses. The influence of elements of parenting style, child characteristics, and family background as predictors of outcomes were examined. Results: Children using bilateral CIs achieved significantly better vocabulary outcomes and significantly higher scores on the Core and Expressive Language subscales of the Clinical Evaluation of Language Fundamentals (fourth edition) than did comparable children with unilateral CIs. Scores on the Preschool Language Scales (fourth edition) did not differ significantly between children with unilateral and bilateral CIs. Bilateral CI use was found to predict significantly faster rates of vocabulary and language development than unilateral CI use; the magnitude of this effect was moderated by child age at activation of the bilateral CI. In terms of parenting style, high levels of parental involvement, low amounts of

  5. A prospective study evaluating cochlear implant management skills: development and validation of the Cochlear Implant Management Skills survey.

    Science.gov (United States)

    Bennett, R J; Jayakody, D M P; Eikelboom, R H; Taljaard, D S; Atlas, M D

    2016-02-01

    To investigate the ability of cochlear implant (CI) recipients to physically handle and care for their hearing implant device(s) and to identify factors that may influence skills. To assess device management skills, a clinical survey was developed and validated on a clinical cohort of CI recipients. Survey development and validation. A prospective convenience cohort design study. Specialist hearing implant clinic. Forty-nine post-lingually deafened, adult CI recipients, at least 12 months postoperative. Survey test-retest reliability, interobserver reliability and responsiveness. Correlations between management skills and participant demographic, audiometric, clinical outcomes and device factors. The Cochlear Implant Management Skills survey was developed, demonstrating high test-retest reliability (0.878), interobserver reliability (0.972) and responsiveness to intervention (skills training) [t(20) = -3.913, P = 0.001]. Cochlear Implant Management Skills survey scores range from 54.69% to 100% (mean: 83.45%, sd: 12.47). No associations were found between handling skills and participant factors. This is the first study to demonstrate a range in cochlear implant device handling skills in CI recipients and offers clinicians and researchers a tool to systematically and objectively identify shortcomings in CI recipients' device handling skills. © 2015 John Wiley & Sons Ltd.

  6. Expressive Language Development in 45 Cochlear Implanted Children Following 2 Years of Implantation

    Directory of Open Access Journals (Sweden)

    Seyed Basir Hashemi

    2011-10-01

    Full Text Available Objectives: Profound hearing loss encounters children with delay in speech and language. As it is known language acquisition in young deaf children is a lengthy process, but cochlear implanted children have better spoken language skills than if they had not received the device. According to the importance of cochlear implant in deaf child's language development, this study evaluates the effect of different variables on child's language performance. Methods: 45 cochlear implanted children were tested, all of whom had used the device for at least 2 years. In order to evaluate the children, the NEWSHA test which is fitted for Persian speaking children was performed and language development of the children was compared through stepwise discriminant analysis. Results: After evaluation of the effect of different variables like child's age of implantation, participating in rehabilitation classes, parent's cooperation and their level of education, we came to a conclusion that the child's age of implantation and rehabilitation program significantly develop the child's language performance. Discussion: The value of cochlear implant in improvement of deaf children in speech, language perception, production and comprehension is confirmed by different studies which have been done on cochlear implanted children. Also, the present study indicates that language development in cochlear implanted children is highly related to their age of implantation and rehabilitation program.

  7. A speech processing study using an acoustic model of a multiple-channel cochlear implant

    Science.gov (United States)

    Xu, Ying

    1998-10-01

    A cochlear implant is an electronic device designed to provide sound information for adults and children who have bilateral profound hearing loss. The task of representing speech signals as electrical stimuli is central to the design and performance of cochlear implants. Studies have shown that the current speech- processing strategies provide significant benefits to cochlear implant users. However, the evaluation and development of speech-processing strategies have been complicated by hardware limitations and large variability in user performance. To alleviate these problems, an acoustic model of a cochlear implant with the SPEAK strategy is implemented in this study, in which a set of acoustic stimuli whose psychophysical characteristics are as close as possible to those produced by a cochlear implant are presented on normal-hearing subjects. To test the effectiveness and feasibility of this acoustic model, a psychophysical experiment was conducted to match the performance of a normal-hearing listener using model- processed signals to that of a cochlear implant user. Good agreement was found between an implanted patient and an age-matched normal-hearing subject in a dynamic signal discrimination experiment, indicating that this acoustic model is a reasonably good approximation of a cochlear implant with the SPEAK strategy. The acoustic model was then used to examine the potential of the SPEAK strategy in terms of its temporal and frequency encoding of speech. It was hypothesized that better temporal and frequency encoding of speech can be accomplished by higher stimulation rates and a larger number of activated channels. Vowel and consonant recognition tests were conducted on normal-hearing subjects using speech tokens processed by the acoustic model, with different combinations of stimulation rate and number of activated channels. The results showed that vowel recognition was best at 600 pps and 8 activated channels, but further increases in stimulation rate and

  8. Pneumococcal meningitis post-cochlear implantation: preventative measures.

    Science.gov (United States)

    Wei, Benjamin P C; Shepherd, Robert K; Robins-Browne, Roy M; Clark, Graeme M; O'Leary, Stephen J

    2010-11-01

    Both clinical data and laboratory studies demonstrated the risk of pneumococcal meningitis post-cochlear implantation. This review examines strategies to prevent post-implant meningitis. Medline/PubMed database; English articles after 1980. Search terms: cochlear implants, pneumococcus meningitis, streptococcus pneumonia, immunization, prevention. Narrative review. All articles relating to post-implant meningitis without any restriction in study designs were assessed and information extracted. The presence of inner ear trauma as a result of surgical technique or cochlear implant electrode array design was associated with a higher risk of post-implant meningitis. Laboratory data demonstrated the effectiveness of pneumococcal vaccination in preventing meningitis induced via the hematogenous route of infection. Fibrous sealing around the electrode array at the cochleostomy site, and the use of antibiotic-coated electrode array reduced the risk of meningitis induced via an otogenic route. The recent scientific data support the U.S. Food and Drug Administration recommendation of pneumococcal vaccination for the prevention of meningitis in implant recipients. Nontraumatic cochlear implant design, surgical technique, and an adequate fibrous seal around the cochleostomy site further reduce the risk of meningitis. Copyright © 2010 American Academy of Otolaryngology–Head and Neck Surgery Foundation. Published by Mosby, Inc. All rights reserved.

  9. [Cochlear implantation in patients with Waardenburg syndrome type II].

    Science.gov (United States)

    Wan, Liangcai; Guo, Menghe; Chen, Shuaijun; Liu, Shuangriu; Chen, Hao; Gong, Jian

    2010-05-01

    To describe the multi-channel cochlear implantation in patients with Waardenburg syndrome including surgeries, pre and postoperative hearing assessments as well as outcomes of speech recognition. Multi-channel cochlear implantation surgeries have been performed in 12 cases with Waardenburg syndrome type II in our department from 2000 to 2008. All the patients received multi-channel cochlear implantation through transmastoid facial recess approach. The postoperative outcomes of 12 cases were compared with 12 cases with no inner ear malformation as a control group. The electrodes were totally inserted into the cochlear successfully, there was no facial paralysis and cerebrospinal fluid leakage occurred after operation. The hearing threshold in this series were similar to that of the normal cochlear implantation. After more than half a year of speech rehabilitation, the abilities of speech discrimination and spoken language of all the patients were improved compared with that of preoperation. Multi-channel cochlear implantation could be performed in the cases with Waardenburg syndrome, preoperative hearing and images assessments should be done.

  10. Diversity in cochlear morphology and its influence on cochlear implant electrode position

    NARCIS (Netherlands)

    Marel, K.S. van der; Briaire, J.J.; Wolterbeek, R..; Snel-Bongers, J.; Verbist, B.M.; Frijns, J.H.

    2014-01-01

    To define a minimal set of descriptive parameters for cochlear morphology and study its influence on the cochlear implant electrode position in relation to surgical insertion distance.Cochlear morphology and electrode position were analyzed using multiplanar reconstructions of the pre- and

  11. Can cochlear implantation improve neurocognition in the aging population?

    Directory of Open Access Journals (Sweden)

    Völter C

    2018-04-01

    Full Text Available Christiane Völter,1 Lisa Götze,1 Stefan Dazert,1 Michael Falkenstein,2,3 Jan Peter Thomas1 1Department of Otorhinolaryngology, Head and Neck Surgery, Ruhr University Bochum, St. Elisabeth-Hospital, Bochum, Germany; 2Institute for Work, Learning and Ageing (ALA, Bochum, Germany; 3Leibniz Research Centre for Working Environment and Human Factors, Dortmund, Germany Introduction: The relationship between cognition and the ability to hear is well known. Due to changes in demographics, the number of people with sensorineural hearing loss and cognitive impairment is increasing. The aim of this study was to identify the impact of hearing rehabilitation via cochlear implantation on cognitive decline among the aging population. Patients and methods: This prospective study included 60 subjects aged between 50 and 84 years (mean 65.8 years, SD=8.9 with a severe to profound bilateral hearing impairment. A computer-based evaluation of short- and long-term memory, processing speed, attention, working memory and inhibition was performed prior to surgery as well as 6 and 12 months after cochlear implantation. Additionally, speech perception at 65 and 80 dB (Freiburger monosyllabic speech test as well as disease-related (Nijmegen Cochlear Implant Questionnaire and general (WHOQOL-OLD quality of life were assessed. Results: Six months postimplantation, speech perception, quality of life and also neurocognitive abilities significantly increased. The most remarkable improvement after 6 months was detected in executive functions such as attention (p<0.001, inhibition (p=0.025 and working memory (n-back: p=0.002; operation span task: p=0.008, followed by delayed recall (p=0.03. In contrast, long-term memory showed a significant change of performance only after 12 months (p=0.021. After 6 months, most cognitive domains remained stable, except working memory assessed by the operation span task, which significantly improved between 6 and 12 months (p<0.001. No

  12. Beneficios económicos del implante coclear para la hipoacusia sensorineural profunda Economic benefits of the cochlear implant for treating profound sensorineural hearing loss

    Directory of Open Access Journals (Sweden)

    Augusto Peñaranda

    2012-04-01

    Full Text Available OBJETIVO: Evaluar el costo-beneficio (CB, costo-utilidad (CU y costo-efectividad (CE de la implantación coclear, comparándola con el uso de audífonos en niños con hipoacusia sensorineural profunda bilateral. MÉTODOS: Se empleó la técnica no paramétrica Propensity Score Matching (PSM para realizar la evaluación de impacto económico del implante y así llevar a cabo los análisis CB, CU y CE. Se utilizó información primaria, tomada aleatoriamente a 100 pacientes: 62 intervenidos quirúrgicamente con el implante coclear (grupo de tratamiento y 38 pertenecientes al grupo de control o usuarios de audífono para tratar la hipoacusia sensorineural profunda. RESULTADOS: Se halló un diferencial de costos económicos -en beneficio del implante coclear- cercano a US$ 204 000 entre el implante y el uso de audífonos durante la esperanza de vida de los pacientes analizados. Dicha cifra indica los mayores gastos que deben cubrir los pacientes con audífono. Con este valor descontado, el indicador costo-beneficio señala que por cada dólar invertido en el implante coclear, para tratar al paciente, el retorno de la inversión es US$ 2,07. CONCLUSIONES: El implante coclear genera beneficios económicos para el paciente. También produce utilidades en salud dado que se encontró una relación positiva de CU (ganancia en decibeles y CE (ganancia en discriminación del lenguaje.OBJECTIVE: Evaluate the cost-benefit, cost-utility, and cost-effectiveness of cochlear implantation, comparing it to the use of hearing aids in children with profound bilateral sensorineural hearing loss. METHODS: The nonparametric propensity score matching method was used to carry out an economic and impact assessment of the cochlear implant and then perform cost-benefit, cost-utility, and cost-effectiveness analyses. Primary information was used, taken randomly from 100 patients: 62 who received cochlear implants (treatment group and 38 belonging to the control group who used

  13. The Hearing Outcomes of Cochlear Implantation in Waardenburg Syndrome.

    Science.gov (United States)

    Koyama, Hajime; Kashio, Akinori; Sakata, Aki; Tsutsumiuchi, Katsuhiro; Matsumoto, Yu; Karino, Shotaro; Kakigi, Akinobu; Iwasaki, Shinichi; Yamasoba, Tatsuya

    2016-01-01

    Objectives. This study aimed to determine the feasibility of cochlear implantation for sensorineural hearing loss in patients with Waardenburg syndrome. Method. A retrospective chart review was performed on patients who underwent cochlear implantation at the University of Tokyo Hospital. Clinical classification, genetic mutation, clinical course, preoperative hearing threshold, high-resolution computed tomography of the temporal bone, and postoperative hearing outcome were assessed. Result. Five children with Waardenburg syndrome underwent cochlear implantation. The average age at implantation was 2 years 11 months (ranging from 1 year 9 months to 6 years 3 months). Four patients had congenital profound hearing loss and one patient had progressive hearing loss. Two patients had an inner ear malformation of cochlear incomplete partition type 2. No surgical complication or difficulty was seen in any patient. All patients showed good hearing outcome postoperatively. Conclusion. Cochlear implantation could be a good treatment option for Waardenburg syndrome.

  14. The Hearing Outcomes of Cochlear Implantation in Waardenburg Syndrome

    Directory of Open Access Journals (Sweden)

    Hajime Koyama

    2016-01-01

    Full Text Available Objectives. This study aimed to determine the feasibility of cochlear implantation for sensorineural hearing loss in patients with Waardenburg syndrome. Method. A retrospective chart review was performed on patients who underwent cochlear implantation at the University of Tokyo Hospital. Clinical classification, genetic mutation, clinical course, preoperative hearing threshold, high-resolution computed tomography of the temporal bone, and postoperative hearing outcome were assessed. Result. Five children with Waardenburg syndrome underwent cochlear implantation. The average age at implantation was 2 years 11 months (ranging from 1 year 9 months to 6 years 3 months. Four patients had congenital profound hearing loss and one patient had progressive hearing loss. Two patients had an inner ear malformation of cochlear incomplete partition type 2. No surgical complication or difficulty was seen in any patient. All patients showed good hearing outcome postoperatively. Conclusion. Cochlear implantation could be a good treatment option for Waardenburg syndrome.

  15. Cochlear implantation for single-sided deafness and tinnitus suppression.

    Science.gov (United States)

    Holder, Jourdan T; O'Connell, Brendan; Hedley-Williams, Andrea; Wanna, George

    To quantify the potential effectiveness of cochlear implantation for tinnitus suppression in patients with single-sided deafness using the Tinnitus Handicap Inventory. The study included 12 patients with unilateral tinnitus who were undergoing cochlear implantation for single-sided deafness. The Tinnitus Handicap Inventory was administered at the patient's cochlear implant candidacy evaluation appointment prior to implantation and every cochlear implant follow-up appointment, except activation, following implantation. Patient demographics and speech recognition scores were also retrospectively recorded using the electronic medical record. A significant reduction was found when comparing Tinnitus Handicap Inventory score preoperatively (61.2±27.5) to the Tinnitus Handicap Inventory score after three months of cochlear implant use (24.6±28.2, p=0.004) and the Tinnitus Handicap Inventory score beyond 6months of CI use (13.3±18.9, p=0.008). Further, 45% of patients reported total tinnitus suppression. Mean CNC word recognition score improved from 2.9% (SD 9.4) pre-operatively to 40.8% (SD 31.7) by 6months post-activation, which was significantly improved from pre-operative scores (p=0.008). The present data is in agreement with previously published studies that have shown an improvement in tinnitus following cochlear implantation for the large majority of patients with single-sided deafness. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Spatial Release From Masking in Simulated Cochlear Implant Users With and Without Access to Low-Frequency Acoustic Hearing

    Directory of Open Access Journals (Sweden)

    Ben Williges

    2015-12-01

    Full Text Available For normal-hearing listeners, speech intelligibility improves if speech and noise are spatially separated. While this spatial release from masking has already been quantified in normal-hearing listeners in many studies, it is less clear how spatial release from masking changes in cochlear implant listeners with and without access to low-frequency acoustic hearing. Spatial release from masking depends on differences in access to speech cues due to hearing status and hearing device. To investigate the influence of these factors on speech intelligibility, the present study measured speech reception thresholds in spatially separated speech and noise for 10 different listener types. A vocoder was used to simulate cochlear implant processing and low-frequency filtering was used to simulate residual low-frequency hearing. These forms of processing were combined to simulate cochlear implant listening, listening based on low-frequency residual hearing, and combinations thereof. Simulated cochlear implant users with additional low-frequency acoustic hearing showed better speech intelligibility in noise than simulated cochlear implant users without acoustic hearing and had access to more spatial speech cues (e.g., higher binaural squelch. Cochlear implant listener types showed higher spatial release from masking with bilateral access to low-frequency acoustic hearing than without. A binaural speech intelligibility model with normal binaural processing showed overall good agreement with measured speech reception thresholds, spatial release from masking, and spatial speech cues. This indicates that differences in speech cues available to listener types are sufficient to explain the changes of spatial release from masking across these simulated listener types.

  17. Outcomes of cochlear implantation in deaf children of deaf parents: comparative study.

    Science.gov (United States)

    Hassanzadeh, S

    2012-10-01

    This retrospective study compared the cochlear implantation outcomes of first- and second-generation deaf children. The study group consisted of seven deaf, cochlear-implanted children with deaf parents. An equal number of deaf children with normal-hearing parents were selected by matched sampling as a reference group. Participants were matched based on onset and severity of deafness, duration of deafness, age at cochlear implantation, duration of cochlear implantation, gender, and cochlear implant model. We used the Persian Auditory Perception Test for the Hearing Impaired, the Speech Intelligibility Rating scale, and the Sentence Imitation Test, in order to measure participants' speech perception, speech production and language development, respectively. Both groups of children showed auditory and speech development. However, the second-generation deaf children (i.e. deaf children of deaf parents) exceeded the cochlear implantation performance of the deaf children with hearing parents. This study confirms that second-generation deaf children exceed deaf children of hearing parents in terms of cochlear implantation performance. Encouraging deaf children to communicate in sign language from a very early age, before cochlear implantation, appears to improve their ability to learn spoken language after cochlear implantation.

  18. Fourteen-years experience with cochlear implantation in Ramathibodi Hospital.

    Science.gov (United States)

    Kasemsuwan, Lalida; Cheewaruangroj, Wichit; Tungkeeratichai, Jumroon; Bhongmakapat, Thongchai; Thawin, Cheamchit; Lertsukprasert, Krisna; Tiravanitchakul, Rattinan; Dara, Rada; Laothamatas, Jiraporn

    2010-12-01

    To review the cochlear implant program in Ramathibodi Hospital and share experience of cochlear implantation emphasized on clinical and surgical outcomes. Retrospective review of 143 ears (140 patients) operated with cochlear implant between 1995 and 2009. The demographic data including etiology of deafness and findings from temporal bone CTscans were reviewed. The authors' experience with cochlear implant surgery in terms of patient selection, patient advisory clinic, necessary equipment, pre- and postoperative evaluations, surgical techniques and complications were discussed. Most congenital origin was unknown etiology and congenital rubella was the most common known cause. From the CT scans of congenital deafness, vestibular aqueduct dilatation was the most common and found in 29.31% while Mondini malformation was shown to be 16.37%. The authors' surgical technique of using the pocket method and designed bony ridge at cortical mastoid rim had helped stabilizing the implant and electrode fancoil. During the last two years, no complication or revision surgery was detected. Cochlear implant surgery in both children and adults can result in good surgical outcome and fewer complications under experienced surgeons and a good team.

  19. Influence of cochlear implantation on peripheral vestibular receptor function.

    Science.gov (United States)

    Krause, Eike; Louza, Julia P R; Wechtenbruch, Juliane; Gürkov, Robert

    2010-06-01

    The objectives of this study were 1) to assess the influence of a cochlear implantation on peripheral vestibular receptor function in the inner ear in the implant and in the nonimplant side, and 2) to analyze a possible correlation with resulting vertigo symptoms. Prospective clinical study. Cochlear implant center at tertiary referral hospital. A total of 32 patients, aged 15 to 83 years, undergoing cochlear implantation were assessed pre- and postoperatively for caloric horizontal semicircular canal response and vestibular-evoked myogenic potentials of the sacculus, and postoperatively for subjective vertigo symptoms. Patients with vertigo were compared with patients without symptoms with regard to the findings of the vestibular function tests. Cochlear implantation represents a significant risk factor for horizontal semicircular canal impairment (P 0.05). Cochlear implantation is a relevant risk factor for damage of peripheral vestibular receptor function. Therefore, preservation not only of residual hearing function but also of vestibular function should be aimed for, by using minimally invasive surgical techniques. Copyright 2010 American Academy of Otolaryngology-Head and Neck Surgery Foundation. Published by Mosby, Inc. All rights reserved.

  20. [Emotional response to music by postlingually-deafened adult cochlear implant users].

    Science.gov (United States)

    Wang, Shuo; Dong, Ruijuan; Zhou, Yun; Li, Jing; Qi, Beier; Liu, Bo

    2012-10-01

    To assess the emotional response to music by postlingually-deafened adult cochlear implant users. Munich music questionnaire (MUMU) was used to match the music experience and the motivation of use of music between 12 normal-hearing and 12 cochlear implant subjects. Emotion rating test in Musical Sounds in Cochlear Implants (MuSIC) test battery was used to assess the emotion perception ability for both normal-hearing and cochlear implant subjects. A total of 15 pieces of music phases were used. Responses were given by selecting the rating scales from 1 to 10. "1" represents "very sad" feeling, and "10" represents "very happy feeling. In comparison with normal-hearing subjects, 12 cochlear implant subjects made less active use of music for emotional purpose. The emotion ratings for cochlear implant subjects were similar to normal-hearing subjects, but with large variability. Post-lingually deafened cochlear implant subjects on average performed similarly in emotion rating tasks relative to normal-hearing subjects, but their active use of music for emotional purpose was obviously less than normal-hearing subjects.

  1. Exploring the experiences of teenagers with cochlear implants.

    Science.gov (United States)

    Watson, Victoria; Verschuur, Carl; Lathlean, Judith

    2016-11-01

    Teenage cochlear implant users' perceptions of deafness, surgery, fitting of the device and life as a cochlear implant wearer were explored in order to gain a more comprehensive understanding of teenagers' experiences of living with the device. Semi-structured in-depth interviews were undertaken and analysed using thematic analysis. Ten teenagers aged 14-16 years with at least one cochlear implant were interviewed. Seven teenagers experienced great pre-operative anxiety and two reported significant post-operative pain. Four of the teenagers described a mismatch between their expectations and the disappointing reality of adjusting to the device. However, all the teenagers reported an enhanced sense of well-being as a result of being able to interact more easily with their world around them. The teenagers differed in the extent to which they identified with the hearing and deaf world. Despite the early challenges, over time the teenagers experienced many functional and psychosocial benefits. Most felt their lives were now easier as a result of the cochlear implant(s). They described complex, flexible identities. By giving prominence to the teenagers' voices this study has added new knowledge concerning their experience of surgery. The findings also more fully revealed the challenges of adjusting to the device and the impact of having a cochlear implant on the teenagers' identities. Clinical recommendations are made to address the gaps in service highlighted by these findings.

  2. Focused tight dressing does not prevent cochlear implant magnet migration under 1.5 Tesla MRI.

    Science.gov (United States)

    Cuda, D; Murri, A; Succo, G

    2013-04-01

    We report a retrospective case of inner magnet migration, which occurred after 1.5 Tesla MRI scanning in an adult recipient of a bilateral cochlear implant (CI) despite a focused head dressing. The patient, bilaterally implanted with Nucleus 5 CIs (Cochlear LTD, Sydney, Australia), underwent a 1.5 Tesla cholangio-MRI scan for biliary duct pathology. In subsequent days, a focal skin alteration appeared over the left inner coil. Plain skull radiographs showed partial magnet migration on the left side. Surgical exploration confirmed magnet twisting; the magnet was effectively repositioned. Left CI performance was restored to pre-migration level. The wound healed without complications. Thus, focused dressing does not prevent magnet migration in CI recipients undergoing 1.5 Tesla MRI. All patients should be counselled on this potential complication. A minor surgical procedure is required to reposition the magnet. Nevertheless, timely diagnosis is necessary to prevent skin breakdown and subsequent device contamination. Plain skull radiograph is very effective in identifying magnet twisting; it should be performed systematically after MRI or minimally on all suspected cases.

  3. Verbal Working Memory in Children With Cochlear Implants

    Science.gov (United States)

    Caldwell-Tarr, Amanda; Low, Keri E.; Lowenstein, Joanna H.

    2017-01-01

    Purpose Verbal working memory in children with cochlear implants and children with normal hearing was examined. Participants Ninety-three fourth graders (47 with normal hearing, 46 with cochlear implants) participated, all of whom were in a longitudinal study and had working memory assessed 2 years earlier. Method A dual-component model of working memory was adopted, and a serial recall task measured storage and processing. Potential predictor variables were phonological awareness, vocabulary knowledge, nonverbal IQ, and several treatment variables. Potential dependent functions were literacy, expressive language, and speech-in-noise recognition. Results Children with cochlear implants showed deficits in storage and processing, similar in size to those at second grade. Predictors of verbal working memory differed across groups: Phonological awareness explained the most variance in children with normal hearing; vocabulary explained the most variance in children with cochlear implants. Treatment variables explained little of the variance. Where potentially dependent functions were concerned, verbal working memory accounted for little variance once the variance explained by other predictors was removed. Conclusions The verbal working memory deficits of children with cochlear implants arise due to signal degradation, which limits their abilities to acquire phonological awareness. That hinders their abilities to store items using a phonological code. PMID:29075747

  4. Multichannel cochlear implantation in the scala vestibuli.

    Science.gov (United States)

    Lin, Karen; Marrinan, Michelle S; Waltzman, Susan B; Roland, J Thomas

    2006-08-01

    Sensorineural hearing loss resulting from otosclerosis, meningitis, chronic otitis media, autoimmune ear disease, and trauma can be associated with partial or total obstruction of the cochlear scalae. Multichannel cochlear implantation may be difficult in a cochlea with an obstructed scala tympani. The purpose of this study is to determine the safety and efficacy of scala tympani electrode insertion. Retrospective chart review. Academic medical center. Eight children and adults with profound sensorineural hearing loss who underwent cochlear implantation with known scala vestibuli electrode array insertion were subjects for this study. Eight study subjects underwent implantation: five with the Nucleus 24RCS (Contour) device and three with the Nucleus 24M device. Imaging findings, operative findings, and age-appropriate speech perception testing. All patients had full electrode insertion. Various obstructive patterns on computed tomography and magnetic resonance imaging were found, and there was a range of speech perception results. All but one patient improved based on age-appropriate monosyllabic word and sentence tests. Scala vestibuli multielectrode insertion is a viable alternative when scala tympani insertion is not possible because of abnormal anatomy or anatomical changes secondary to disease or previous implantation. We will also present an algorithm of options for decision making for implantation when encountering cochlear obstruction and difficult electrode insertion.

  5. Cochlear implantation in Waardenburg syndrome: The Indian scenario.

    Science.gov (United States)

    Deka, Ramesh Chandra; Sikka, Kapil; Chaturvedy, Gaurav; Singh, Chirom Amit; Venkat Karthikeyan, C; Kumar, Rakesh; Agarwal, Shivani

    2010-10-01

    Children with Waardenburg syndrome (WS) exhibiting normal inner ear anatomy, like those included in our cohort, derive significant benefit from cochlear implantation and results are comparable to those reported for the general population of implanted children. The patient population of WS accounts for approximately 2% of congenitally deaf children. The purpose of this retrospective case review was to describe the outcomes for those children with WS who have undergone cochlear implantation. On retrospective chart review, there were four cases with WS who underwent cochlear implantation. These cases were assessed for age at implantation, clinical and radiological features, operative and perioperative course, and performance outcomes. Auditory perception and speech production ability were evaluated using categories of auditory performance (CAP), meaningful auditory integration scales (MAIS), and speech intelligibility rating (SIR) during the follow-up period. In this group of children with WS, with a minimum follow-up of 12 months, the CAP score ranged from 3 to 5, MAIS from 25 to 30, and SIR was 3. These scores are comparable with those of other cochlear implantees.

  6. Binaural release from masking with single- and multi-electrode stimulation in children with cochlear implants.

    Science.gov (United States)

    Todd, Ann E; Goupell, Matthew J; Litovsky, Ruth Y

    2016-07-01

    Cochlear implants (CIs) provide children with access to speech information from a young age. Despite bilateral cochlear implantation becoming common, use of spatial cues in free field is smaller than in normal-hearing children. Clinically fit CIs are not synchronized across the ears; thus binaural experiments must utilize research processors that can control binaural cues with precision. Research to date has used single pairs of electrodes, which is insufficient for representing speech. Little is known about how children with bilateral CIs process binaural information with multi-electrode stimulation. Toward the goal of improving binaural unmasking of speech, this study evaluated binaural unmasking with multi- and single-electrode stimulation. Results showed that performance with multi-electrode stimulation was similar to the best performance with single-electrode stimulation. This was similar to the pattern of performance shown by normal-hearing adults when presented an acoustic CI simulation. Diotic and dichotic signal detection thresholds of the children with CIs were similar to those of normal-hearing children listening to a CI simulation. The magnitude of binaural unmasking was not related to whether the children with CIs had good interaural time difference sensitivity. Results support the potential for benefits from binaural hearing and speech unmasking in children with bilateral CIs.

  7. A new computed tomography method to identify meningitis-related cochlear ossification and fibrosis before cochlear implantation.

    Science.gov (United States)

    Ichikawa, Kazunori; Kashio, Akinori; Mori, Harushi; Ochi, Atushi; Karino, Shotaro; Sakamoto, Takashi; Kakigi, Akinobu; Yamasoba, Tatsuya

    2014-04-01

    To develop a new method to determine the presence of intracochlear ossification and/or fibrosis in cochlear implantation candidates with bilateral profound deafness following meningitis. Diagnostic test assessment. A university hospital. This study involved 15 ears from 13 patients with profound deafness following meningitis who underwent cochlear implantation. These ears showed normal structures, soft tissue, partial bony occlusion, and complete bony occlusion in 4, 3, 2, and 6 ears, respectively. We measured radiodensity in Hounsfield units (HU) using 0.5-mm-thick axial high-resolution computed tomography image slices at 3 different levels in the basal turn, the fenestration, and inferior and ascending segment sites, located along the electrode-insertion path. Pixel-level analysis on the DICOM viewer yielded actual computed tomography values of intracochlear soft tissues by eliminating the partial volume effect. The values were compared with the intraoperative findings. Values for ossification (n = 12) ranged from +547 HU to +1137 HU; for fibrosis (n = 11), from +154 HU to +574 HU; and for fluid (n = 22), from -49 HU to +255 HU. From these values, we developed 2 presets of window width (WW) and window level (WL): (1) WW: 1800, WL: 1100 (200 HU to 2000 HU) and (2) WW: 1500, WL: 1250 (500 HU to 2000 HU). The results using these 2 presets corresponded well to the intraoperative findings. Our new method is easy and feasible for preoperative determination of the presence of cochlear ossification and/or fibrosis that develops following meningitis.

  8. Working memory in Farsi-speaking children with normal development and cochlear implant.

    Science.gov (United States)

    Soleymani, Zahra; Amidfar, Meysam; Dadgar, Hooshang; Jalaie, Shohre

    2014-04-01

    Working memory has an important role in language acquisition and development of cognition skills. The ability of encoding, storage and retrieval of phonological codes, as activities of working memory, acquired by audition sense. Children with cochlear implant experience a period that they are not able to perceive sounds. In order to assess the effect of hearing on working memory, we investigated working memory as a cognition skill in children with normal development and cochlear implant. Fifty students with normal hearing and 50 students with cochlear implant aged 5-7 years participated in this study. Children educated in the preschool, the first and second grades. Children with normal development were matched based on age, gender, and grade of education with cochlear implant. Two components of working memory including phonological loop and central executive were compared between two groups. Phonological loop assessed by nonword repetition task and forward digit span. To assess central executive component backward digit span was used. The developmental trend was studied in children with normal development and cochlear implant as well. The effect of age at implantation in children with cochlear implants on components of working memory was investigated. There are significant differences between children with normal development and cochlear implant in all tasks that assess working memory (p memory between different grades showed significant differences both in children with normal development and in children with cochlear implant (p implied that children with cochlear implant may experience difficulties in working memory. Therefore, these children have problems in encoding, practicing, and repeating phonological units. The results also suggested working memory develops when the child grows up. In cochlear implant children, with decreasing age at implantation and increasing their experience in perceiving sound, working memory skills improved. Copyright © 2014 Elsevier

  9. Barriers to pediatric cochlear implantation: A parental survey.

    Science.gov (United States)

    Yang, Charles Q; Reilly, Brian K; Preciado, Diego A

    2018-01-01

    This study aims to (1) determine barriers in the pediatric cochlear implantation process specific to publicly insured patients, wherein delayed implantation has been reported, and (2) compare the perceived barriers between publicly and privately insured patients. Tertiary care cochlear implantation center at academic pediatric hospital. Cross-sectional survey, retrospective chart review. The validated, 39 item Barriers to Care Questionnaire was administered to the parents of 80 recipients of cochlear implantation by two surgeons between 2013 and 2016. Survey results and diagnosis to implant interval were compared based on public or private insurance status. Two-tailed Mann-Whitney and Fisher's exact test was used for statistical analysis. Of 110 cochlear implants, 27 of 80 (34%) English-speaking parents completed the survey. 15 were privately insured and 12 were publicly insured. 23 of 27 respondents received cochlear implantation for pre-lingual sensorineural hearing loss. Publicly insured patients had significantly longer median time from diagnosis to implant than privately insured (19 vs. 8 mo, p = 0.01). The three worst scoring barrier categories for privately insured families in order were Pragmatics, Expectations, and Marginalization, whereas for publicly insured families it was Pragmatics, Skills, and Expectations. The worst scoring question for privately insured patients was "Having to take time off work". For the publicly insured, it was "Lack of communication." Privately insured patients reported more barriers on the Barriers to Care Questionnaire than publicly insured patients did. Although pragmatics was the worst-scoring barrier category for both groups, difficulties found on the survey ranked differently for each group. This information can help providers address disparities and access barriers for vulnerable patients. Published by Elsevier B.V.

  10. Cochlear implant magnet retrofit.

    Science.gov (United States)

    Cohen, N L; Breda, S D; Hoffman, R A

    1988-06-01

    An implantable magnet is now available for patients who have received the standard Nucleus 22-channel cochlear implant and who are not able to wear the headband satisfactorily. This magnet is attached in piggy-back fashion to the previously implanted receiver/stimulator by means of a brief operation under local anesthesia. Two patients have received this magnet retrofit, and are now wearing the headset with greater comfort and satisfaction. It is felt that the availability of this magnet will increase patient compliance in regard to hours of implant usage.

  11. Costs involved in using a cochlear implant in South Africa

    Directory of Open Access Journals (Sweden)

    Gillian Robyn Kerr

    2012-12-01

    Full Text Available Cochlear implantation is an expensive but effective lifelong intervention for individuals with a severe-to-profound hearing loss. The primary aim of this study was to survey the short- and long-term costs of cochlear implantation. Individuals (N=154 using cochlear implants obtained from the University of Stellenbosch-Tygerberg Hospital Cochlear Implant Unit in Cape Town, South Africa were surveyed using a questionnaire and patient record review. The questionnaire used a combination of closed and open-ended questions to gather both quantitative and qualitative information. Costs were categorised as short- and long-term costs. All costs were converted to constant rands (June 2010 using the Consumer Price Index to allow for comparison in real terms over time. In the first 10 years of implantation the average estimated costs incurred by adults totalled R379 626, and by children R455 225. The initial purchase of the implant system was the most substantial cost, followed by upgrading of the processor. Travel and accommodation costs peaked in the first 2 years. On average the participants spent R2 550 per year on batteries and spares. Rehabilitation for children cost an average of R7 200. Insurance costs averaged R4 040 per year, and processor repairs R3 000 each. In addition to the upfront expense of obtaining the cochlear implant system, individuals using a cochlear implant in South Africa should be prepared for the long-term costs of maintenance, accessing the unit, support services and additional costs associated with use. Knowledge of these costs is important to ensure that individuals are successful users of their cochlear implants in the long term.

  12. Libyan cochlear implant programme: achievements, difficulties, and future goals

    Directory of Open Access Journals (Sweden)

    Samya El-Ogbi

    2011-05-01

    Full Text Available Cochlear implantation has become established worldwide as a safe and effective method of auditory rehabilitation of selected severely and profound deaf children and adults. Over 100,000 patients have received cochlear implants worldwide with the paediatric population proving to be the main beneficiaries. The Libyan cochlear implant programme was set up in 2004. Data relating to the patients who received cochlear implantation at Tripoli Medical Centre between October 2007 and February 2010 were analysed. Implant operations were performed on 37 patients. All patients received Med-El SONATATI 100 devices. Thirty-four (91.9% of these patients were children, whilst three (8.1% were adults. Combined, congenital hearing loss (56.8% and perinatal/neonatal (29.7% were the two main aetiological factors in children. Seventeen patients (45.9% had a positive family history of deafness. Sixteen patients (43.2% were born to blood-related parents. The overall rate of minor and major complications was 16.2%, which is comparable to previous studies.

  13. Libyan cochlear implant programme: achievements, difficulties, and future goals.

    Science.gov (United States)

    Salamat, Ali; Esriti, Anwer; Ehtuish, Asia; El-Ogbi, Samya

    2011-01-01

    Cochlear implantation has become established worldwide as a safe and effective method of auditory rehabilitation of selected severely and profound deaf children and adults. Over 100,000 patients have received cochlear implants worldwide with the paediatric population proving to be the main beneficiaries. The Libyan cochlear implant programme was set up in 2004. Data relating to the patients who received cochlear implantation at Tripoli Medical Centre between October 2007 and February 2010 were analysed. Implant operations were performed on 37 patients. All patients received Med-El SONATA(TI) (100) devices. Thirty-four (91.9%) of these patients were children, whilst three (8.1%) were adults. Combined, congenital hearing loss (56.8%) and perinatal/neonatal (29.7%) were the two main aetiological factors in children. Seventeen patients (45.9%) had a positive family history of deafness. Sixteen patients (43.2%) were born to blood-related parents. The overall rate of minor and major complications was 16.2%, which is comparable to previous studies.

  14. Production of verb tenses in children with cochlear implants

    Directory of Open Access Journals (Sweden)

    Sokolovac Ivana

    2016-01-01

    Full Text Available The production of verb tenses leads to better language development of children with cochlear implants. The aim of this study was to assess the acquisition of verb tenses in children with cochlear implants. The sample included 60 children, aged from 9 to 15, with average intellectual abilities. The study group consisted of 30 patients with cochlear implants, with no additional disabilities. The control group consisted of 30 subjects with typical speech - language development and preserved hearing. The acquisition of basic tenses was assessed by 'Corpus for the Assessment of the Use of Tenses' (Dimić, 2003. Significant statistical differences were found in the use of the present tense in children with cochlear implants and hearing children (t=-4.385; p<0.001 as well as in the use of the past tense (t=-4.650; p<0.001, and the future tense (t=-4.269; p<0.001. There was also a significant difference in the use of irregular verb 'go' (t=-3.958; p<0.001, as well as in the combination of the present and the past tense (t=-5.806; p<0.001. The present tense was used correctly by most children with cochlear implants (70%, followed by the past tense (53%, and finally the future tense (23%. Children with cochlear implants, even after several years of re/habilitation, do not reach the grammatical development of children with normal hearing.

  15. Threshold shift: effects of cochlear implantation on the risk of pneumococcal meningitis.

    Science.gov (United States)

    Wei, Benjamin P C; Shepherd, Robert K; Robins-Browne, Roy M; Clark, Graeme M; O'Leary, Stephen J

    2007-04-01

    The study goals were to examine whether cochlear implantation increases the risk of meningitis in the absence of other risk factors and to understand the pathogenesis of pneumococcal meningitis post cochlear implantation. Four weeks following surgery, 54 rats (18 of which received a cochleostomy alone, 18 of which received a cochleostomy and acute cochlear implantation using standard surgical techniques, and 18 of which received a cochlear implant) were infected with Streptococcus pneumoniae via three different routes of bacterial inoculation (middle ear, inner ear, and intraperitoneal) to represent all potential routes of bacterial infection from the upper respiratory tract to the meninges. The presence of a cochlear implant reduced the threshold of bacteria required to cause pneumococcal meningitis from all routes of infection in healthy animals. The presence of a cochlear implant increases the risk of pneumococcal meningitis regardless of the route of bacterial infection. Early detection and treatment of pneumococcal infection such as otitis media may be required, as cochlear implantation may lead to a reduction of infectious threshold for meningitis.

  16. Verbal Working Memory in Children with Cochlear Implants

    Science.gov (United States)

    Nittrouer, Susan; Caldwell-Tarr, Amanda; Low, Keri E.; Lowenstein, Joanna H.

    2017-01-01

    Purpose: Verbal working memory in children with cochlear implants and children with normal hearing was examined. Participants: Ninety-three fourth graders (47 with normal hearing, 46 with cochlear implants) participated, all of whom were in a longitudinal study and had working memory assessed 2 years earlier. Method: A dual-component model of…

  17. Cochlear implantation in X-linked deafness - How to manage the surgical challenges.

    Science.gov (United States)

    Saeed, Haroon; Powell, Harry R F; Saeed, Shakeel R

    2016-07-01

    In children with X-linked deafness, cochlear malformations challenge the implant surgeon to avoid electrode insertion into the internal auditory meatus and prevent a continuous cerebrospinal fluid (CSF) leak. We describe our experience of cochlear implantation (CI) in two children with profound hearing loss secondary to X-linked deafness, highlighting safer operative techniques to avoid potential complications. Descriptive cases of two children with X-linked deafness (patient 1 and patient 2) undergoing CI. Peri-operative imaging and work-up to surgery are discussed. Specific operative considerations, post-operative complications and subsequent audiological performance are highlighted. In each case, intra-operative fluoroscopic imaging ensured intra-cochlear insertion of electrodes. Expected CSF gusher was seen in each case which was initially controlled by packing around the cochleostomy and array with temporalis muscle and fascia. Patient 1 developed post-operative meningitis secondary to continuous CSF leak. We avoided further significant CSF leak by planning staged procedures for patient 2, with obliteration of the middle ear cleft and external ear canal (EAC) at the time of implantation. In both patients, bilateral implantation successfully provided hearing thresholds of less than 35 dB in both ears at routine follow up. When planning for CI in children with radiological features of X-linked deafness, intra-operative imaging should be utilized to ensure correct electrode positioning. Traditional methods of stopping a CSF gusher may not suffice. We therefore encourage additional surgical obliteration of the middle ear space and EAC to avoid persistent CSF leak and its associated complications.

  18. Hair Barrette Induced Cochlear Implant Receiver Stimulator Site Infection with Extrusion

    Directory of Open Access Journals (Sweden)

    Trung N. Le

    2015-01-01

    Full Text Available Background. Cochlear implant infections and extrusion are uncommon but potentially devastating complications. Recent literature suggests conservative management can be employed. Local measures inclusive of aggressive surgical debridement with vascularized flaps and parenteral antibiotics represent a viable option and often permit device salvage. However, explantation should be considered if there is evidence of systemic, intracranial, or intractable infection. Method. A Case report and literature review. Case Report. This case illustrates a complicated local wound infection associated with cochlear implantation due to transcutaneous adherence of a ferrous hair barrette to a cochlear implant magnet. Reconstruction of computed tomography (CT data with 3D volume rendering significantly improved the value of the images and facilitated patient counseling as well as operative planning. Conclusion. Cochlear implant infections can be associated with foreign bodies. CT images are beneficial in the evaluation of cochlear implant complications. 3D CT images provide a comprehensive view of the site of interest, displaying the relationship of the hardware to the skull and soft tissues, while minimizing associated artifacts. Cochlear implant patients should consider use of nonmetallic hair devices.

  19. Comparison of Persian Simple Vowels Production in Cochlear Implanted Children Based on Implantation Age

    Directory of Open Access Journals (Sweden)

    Peiman Zamani

    2008-07-01

    Full Text Available Objective: Age at implantation is one of the most important factors in improving speech and language skills in children with cochlear implants. Moreover, good vowel articulation is very important in the speech. So, the purpose of this research was to determine whether age at cochlear implantation influences the production of Persian simple vowels when cochlear implantation is undertaken below the age of 2 years as compared with cochlear implantation later in life. Materials & Methods: This research was a comparative and cross-sectional study. Based on inclusive and exclusive criteria (i.e., have physical and mental health, monolingual or bilingual, have 9±1 months post-surgery rehabilitation, no hearing handicapped parents and no medical problems history, 140 children who cochlear implanted in Amir-Alam and Hazrate Rasool hospital of Tehran city were selected by convenient sampling and assigned to two groups, children implanted under the age of 2 years and those implanted above the age of 2 years Also 238 normally hearing children were selected for control group by randomized sampling. The first and second formant frequency (F1 & F2 of the Persian simple vowels /i, e, æ, a, o, u/ were evaluated by the version of 1.2 of SFSwin software. Data were analyzed by Independent T test. Results: The findings indicated that there were significant differences between two groups in the mean of F2/i/ (P=0.046, F1/e/ (P=0.011, F2/e/ (P=0.005, F2/æ/ (P=0.039, F2/a/ (P=0.012, F2/o/ (P=0.012 and F2/u/ (P=0.006, but there was no significant difference between then in the mean of F1/i/, F1/æ/, F2/a/, F1/o/, F1/u/ (P>0.05. According to these results, no significant difference was seen between normal group and children who received their cochlear implants under the age of 2 years in the mean of variables (P>0.05. Conclusion: Observing significant differences in the quality of the production of Persian simple vowels between children implanted under the age of 2

  20. The preoperative imaging evaluation for cochlear implantation

    International Nuclear Information System (INIS)

    Liu Zhonglin; Wang Zhenchang; Fu Lin; Li Yong; Xian Junfang; Yang Bentao; Lan Baosen; Li Yongxin; Zheng Jun; Song Yan; Liu Bo; Chen Xueqing; He Haili

    2006-01-01

    Objective: To analyze CT and MRI findings of temporal bone and to evaluate preoperative diagnostic value for cochlear implantation. Methods: One hundred and sixty candidates for cochlear implantation were examined with axial CT scan, 64 of them also with coronal CT scan, and 119 patients with MRI. Results: All of 320 ears were well-aerated, and 206 ears had mastoid cavities extended posteriorly to the sigmoid sinus. The length from posterior-lateral tympanic wall to the outer cortex was (2.34±0.42) mm (left side) and (2.25±0.40) mm (right side) (U=1.887, P 1 and T 2 signal on MRI. The congenital malformations of inner ear occurred in 67 ears, including complete dysplasia in 1 ear, cochlear hypodysplasia in 6 ears, Mondini deformation in 5 ears, enlarged vestibular aqueduct in 40 ears, dysplastic semicircular canal and the vestibulae in 10 ears, and narrowing of internal auditory canal in 5 ears. Conclusion: Preoperative imaging examinations can provide critical information to ensure successful cochlear' implantation. (authors)

  1. Is cochlear implantation a good treatment method for profoundly deafened elderly?

    Directory of Open Access Journals (Sweden)

    Lachowska M

    2013-10-01

    Full Text Available Magdalena Lachowska, Agnieszka Pastuszka, Paulina Glinka, Kazimierz Niemczyk Department of Otolaryngology, Hearing Implant Center, Medical University of Warsaw, Warsaw, Poland Purpose: To assess the benefits of cochlear implantation in the elderly. Patients and methods: A retrospective analysis of 31 postlingually deafened elderly (≥60 years of age with unilateral cochlear implants was conducted. Audiological testing included preoperative and postoperative pure-tone audiometry and a monosyllabic word recognition test presented from recorded material in free field. Speech perception tests included Ling's six sound test (sound detection, discrimination, and identification, syllable discrimination, and monosyllabic and multisyllabic word recognition (open set without lip-reading. Everyday life benefits from cochlear implantation were also evaluated. Results: The mean age at the time of cochlear implantation was 72.4 years old. The mean post-implantation follow-up time was 2.34 years. All patients significantly improved their audiological and speech understanding performances. The preoperative mean pure-tone average threshold for 500 Hz, 1,000 Hz, 2,000 Hz, and 4,000 Hz was 110.17 dB HL. Before cochlear implantation, all patients scored 0% on the monosyllabic word recognition test in free field at 70 dB SPL intensity level. The postoperative pure-tone average was 37.14 dB HL (the best mean threshold was 17.50 dB HL, the worst was 58.75 dB HL. After the surgery, mean monosyllabic word recognition reached 47.25%. Speech perception tests showed statistically significant improvement in speech recognition. Conclusion: The results of this study showed that cochlear implantation is indeed a successful treatment for improving speech recognition and offers a great help in everyday life to deafened elderly patients. Therefore, they can be good candidates for cochlear implantation and their age alone should not be a relevant or excluding factor when choosing

  2. Suitability of the Binaural Interaction Component for Interaural Electrode Pairing of Bilateral Cochlear Implants.

    Science.gov (United States)

    Hu, Hongmei; Kollmeier, Birger; Dietz, Mathias

    2016-01-01

    Although bilateral cochlear implants (BiCIs) have succeeded in improving the spatial hearing performance of bilateral CI users, the overall performance is still not comparable with normal hearing listeners. Limited success can be partially caused by an interaural mismatch of the place-of-stimulation in each cochlea. Pairing matched interaural CI electrodes and stimulating them with the same frequency band is expected to facilitate binaural functions such as binaural fusion, localization, or spatial release from masking. It has been shown in animal experiments that the magnitude of the binaural interaction component (BIC) derived from the wave-eV decreases for increasing interaural place of stimulation mismatch. This motivated the investigation of the suitability of an electroencephalography-based objective electrode-frequency fitting procedure based on the BIC for BiCI users. A 61 channel monaural and binaural electrically evoked auditory brainstem response (eABR) recording was performed in 7 MED-EL BiCI subjects so far. These BiCI subjects were directly stimulated at 60% dynamic range with 19.9 pulses per second via a research platform provided by the University of Innsbruck (RIB II). The BIC was derived for several interaural electrode pairs by subtracting the response from binaural stimulation from their summed monaural responses. The BIC based pairing results are compared with two psychoacoustic pairing methods: interaural pulse time difference sensitivity and interaural pitch matching. The results for all three methods analyzed as a function of probe electrode allow for determining a matched pair in more than half of the subjects, with a typical accuracy of ± 1 electrode. This includes evidence for statistically significant tuning of the BIC as a function of probe electrode in human subjects. However, results across the three conditions were sometimes not consistent. These discrepancies will be discussed in the light of pitch plasticity versus less plastic

  3. Challenges in Improving Cochlear Implant Performance and Accessibility.

    Science.gov (United States)

    Zeng, Fan-Gang

    2017-08-01

    Here I identify two gaps in cochlear implants that have been limiting their performance and acceptance. First, cochlear implant performance has remained largely unchanged, despite the number of publications tripling per decade in the last 30 years. Little has been done so far to address a fundamental limitation in the electrode-to-neuron interface, with the electrode size being a thousand times larger than the neuron diameter while the number of electrodes being a thousand times less. Both the small number and the large size of electrodes produce broad spatial activation and poor frequency resolution that limit current cochlear implant performance. Second, a similarly rapid growth in cochlear implant volume has not produced an expected decrease in unit price in the same period. The high cost contributes to low market penetration rate, which is about 20% in developed countries and less than 1% in developing countries. I will discuss changes needed in both research strategy and business practice to close the gap between prosthetic and normal hearing as well as that between haves and have-nots.

  4. [Cochlear implant in patients with congenital malformation of the inner ear].

    Science.gov (United States)

    Wan, Liang-cai; Guo, Meng-he; Qian, Yu-hong; Liu, Shuang-xiu; Zhang, Hong-zheng; Chen, Shuai-jun; Chen, Hao; Gong, Jian

    2009-10-01

    To summarize the clinical experience with multi-channel cochlear implantation in patients with inner ear malformations and evaluate and the outcomes of speech rehabilitation. A retrospective study was conducted in 295 patients receiving cochlear implantation from 1998 to 2007, including 25 patients with large vestibular aqueduct syndrome (LVAS), 9 with Modini malformation, and 5 with common cavity deformity. All the patients received the Nucleus24 cochlear implants. In LVAS cases, 4 had Nucleus 24R (ST) implants, 8 had Contuor implants, 10 had Contuor Advance, and the remaining cases used Nucleus24(M) straight-electrode implants. Severe gusher appeared in 3 cases of LVAS, and perilymph fluctuation were seen in other 15 cases. Four patients with Mondini malformation and 2 with common cavity malformation also experienced severe gusher, but the electrodes were inserted smoothly in all the patients without postoperative facial paralysis or cerebrospinal fluid leakage. The hearing threshold in these patients was similar to that in patients with normal cochlear structure. After speech rehabilitation for over 6 months, the abilities of speech discrimination and spoken language improved in all the cases in comparison with the preoperative lingual functions. Multi-channel cochlear implantation can be performed in patients with inner ear malformation, but should not be attempted in patients with poor cochlear and cochlear nerve development. A comprehensive pre-operative radiographic and audiological evaluation is essential.

  5. Benefit of a Contralateral Routing of Signal Device for Unilateral Cochlear Implant Users.

    OpenAIRE

    Weder, Stefan; Kompis, Martin; Caversaccio, Marco; Stieger, Christof

    2014-01-01

    Objective: To investigate objective and subjective effects of an adjunctive contralateral routing of signal (CROS) device at the untreated ear in patients with a unilateral cochlear implant (CI). Design: Prospective study of 10 adult experienced unilateral CI users with bilateral severe-to-profound hearing loss. Speech in noise reception (SNR) and sound localization were measured with and without the additional CROS device. SNR was measured by applying speech signals at the untreated/CROS sid...

  6. Preoperative vestibular assessment protocol of cochlear implant surgery: an analytical descriptive study.

    Science.gov (United States)

    Bittar, Roseli Saraiva Moreira; Sato, Eduardo Setsuo; Ribeiro, Douglas Jósimo Silva; Tsuji, Robinson Koji

    Cochlear implants are undeniably an effective method for the recovery of hearing function in patients with hearing loss. To describe the preoperative vestibular assessment protocol in subjects who will be submitted to cochlear implants. Our institutional protocol provides the vestibular diagnosis through six simple tests: Romberg and Fukuda tests, assessment for spontaneous nystagmus, Head Impulse Test, evaluation for Head Shaking Nystagmus and caloric test. 21 patients were evaluated with a mean age of 42.75±14.38 years. Only 28% of the sample had all normal test results. The presence of asymmetric vestibular information was documented through the caloric test in 32% of the sample and spontaneous nystagmus was an important clue for the diagnosis. Bilateral vestibular areflexia was present in four subjects, unilateral arreflexia in three and bilateral hyporeflexia in two. The Head Impulse Test was a significant indicator for the diagnosis of areflexia in the tested ear (p=0.0001). The sensitized Romberg test using a foam pad was able to diagnose severe vestibular function impairment (p=0.003). The six clinical tests were able to identify the presence or absence of vestibular function and function asymmetry between the ears of the same individual. Copyright © 2016 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  7. Cochlear Implants and Psychiatric Assessments: a Norrie Disease Case Report.

    Science.gov (United States)

    Jacques, Denis; Dubois, Thomas; Zdanowicz, Nicolas; Gilain, Chantal; Garin, Pierre

    2017-09-01

    It is important to perform psychiatric assessments of adult patients who are candidates for cochlear implants both to screen them for psychiatric disorders and to assess their understanding and compliance with the procedure. Deafness is a factor of difficulty for conducting in-depth psychiatric interviews, but concomitant blindness may make it impossible. After a description of Norrie disease, a rare disease in which blindness and deafness may occur together, we propose a case report of a patient suffering from the disease and who consulted in view of a cochlear implant. Early information on cochlear implants appears to be necessary before total deafness occurs in patients suffering from Norrie disease. An inventory of digital communication tools that can be used by the patient is also highly valuable. Research should be supported for a more systematic use of psychiatric assessments prior to cochlear implants. In the special case of Norrie disease, we recommend early screening for mental retardation and related psychotic disorders and, depending on the patient's level of understanding, preventive information on the benefits and limits of cochlear implants before total deafness occurs.

  8. Cochlear implant after bacterial meningitis.

    Science.gov (United States)

    Bille, Jesper; Ovesen, Therese

    2014-06-01

    The aim of this retrospective case study at a tertiary referral center was to investigate the outcome of cochlear implantation (CI) in children with sensorineural hearing loss due to meningitis compared to CI in children with deafness due to other reasons. This post-meningial group (PMG) consisted of 22 children undergoing CI due to deafness induced by meningitis, between December 1996 and January 2012. Five children had bilateral simultaneous implantation. None was excluded and the children were followed for at least 3 years. Operations were carried out by one of two surgeons using similar techniques in all cases. Each patient from the PMG was matched 2:1 with children having implantation for other reasons according to age and follow up (control group). Overall, the median category of auditory performance (CAP) and speech intelligibility rating (SIR) score were not statistically significantly different between the two groups. The presence of additional central nervous system (CNS) disorders (post-meningeal sequelae), however, correlated significantly with poorer outcome CI was a safe procedure without surgical complications in the present study. It is possible to restore auditory capacity and speech performance to a degree comparable to children undergoing implantation for other reasons. A statistically important variable is secondary CNS involvement. The rehabilitation program after CI should be adjusted according to these additional handicaps. It is recommended to screen meningitis patients as fast as possible to identify those with hearing loss and initiate treatment with hearing aids or CI. © 2013 The Authors. Pediatrics International © 2013 Japan Pediatric Society.

  9. Cochlear implantation in autistic children with profound sensorineural hearing loss.

    Science.gov (United States)

    Lachowska, Magdalena; Pastuszka, Agnieszka; Łukaszewicz-Moszyńska, Zuzanna; Mikołajewska, Lidia; Niemczyk, Kazimierz

    2016-11-19

    Cochlear implants have become the method of choice for the treatment of severe-to-profound hearing loss in both children and adults. Its benefits are well documented in the pediatric and adult population. Also deaf children with additional needs, including autism, have been covered by this treatment. The aim of this study was to assess the benefits from cochlear implantation in deafened children with autism as the only additional disability. This study analyzes data of six children. The follow-up time was at least 43 months. The following data were analyzed: medical history, reaction to music and sound, Ling's six sounds test, onomatopoeic word test, reaction to spoken child's name, response to requests, questionnaire given to parents, sound processor fitting sessions and data. After cochlear implantation each child presented other communication skills. In some children, the symptoms of speech understanding were observed. No increased hyperactivity associated with daily use cochlear implant was observed. The study showed that in autistic children the perception is very important for a child's sense of security and makes contact with parents easier. Our study showed that oral communication is not likely to be a realistic goal in children with cochlear implants and autism. The implantation results showed benefits that varied among those children. The traditional methods of evaluating the results of cochlear implantation in children with autism are usually insufficient to fully assess the functional benefits. These benefits should be assessed in a more comprehensive manner taking into account the limitations of communication resulting from the essence of autism. It is important that we share knowledge about these complex children with cochlear implants. Copyright © 2016 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  10. Conductive component after cochlear implantation in patients with residual hearing conservation.

    Science.gov (United States)

    Chole, Richard A; Hullar, Timothy E; Potts, Lisa G

    2014-12-01

    Changes in auditory thresholds following cochlear implantation are generally assumed to be due to damage to neural elements. Theoretical studies have suggested that placement of a cochlear implant can cause a conductive hearing loss. Identification of a conductive component following cochlear implantation could guide improvements in surgical techniques or device designs. The purpose of this study is to characterize new-onset conductive hearing losses after cochlear implantation. In a prospective study, air- and bone-conduction audiometric testing were completed on cochlear implant recipients. An air-bone gap equal to or greater than 15 dB HL at 2 frequencies determined the presence of a conductive component. Of the 32 patients with preoperative bone-conduction hearing, 4 patients had a new-onset conductive component resulting in a mixed hearing loss, with air-conduction thresholds ranging from moderate to profound and an average air-bone gap of 30 dB HL. One had been implanted through the round window, 2 had an extended round window, and 1 had a separate cochleostomy. Loss of residual hearing following cochlear implantation may be due in part to a conductive component. Identifying the mechanism for this conductive component may help minimize hearing loss. Postoperative hearing evaluation should measure both air- and bone-conduction thresholds.

  11. The long-term concerns post cochlear implantation as experienced ...

    African Journals Online (AJOL)

    Background. Cochlear implantation aims to provide an effective means of spoken communication for prelingually deaf children. However, studies in this field are mostly clinically orientated, with little focus on the experiences and long-term concerns of families post cochlear implantation (CI). Objective. To describe the ...

  12. A software tool for analyzing multichannel cochlear implant signals.

    Science.gov (United States)

    Lai, Wai Kong; Bögli, Hans; Dillier, Norbert

    2003-10-01

    A useful and convenient means to analyze the radio frequency (RF) signals being sent by a speech processor to a cochlear implant would be to actually capture and display them with appropriate software. This is particularly useful for development or diagnostic purposes. sCILab (Swiss Cochlear Implant Laboratory) is such a PC-based software tool intended for the Nucleus family of Multichannel Cochlear Implants. Its graphical user interface provides a convenient and intuitive means for visualizing and analyzing the signals encoding speech information. Both numerical and graphic displays are available for detailed examination of the captured CI signals, as well as an acoustic simulation of these CI signals. sCILab has been used in the design and verification of new speech coding strategies, and has also been applied as an analytical tool in studies of how different parameter settings of existing speech coding strategies affect speech perception. As a diagnostic tool, it is also useful for troubleshooting problems with the external equipment of the cochlear implant systems.

  13. Rehabilitation of deaf persons with cochlear implants

    International Nuclear Information System (INIS)

    Gstoettner, W.; Hamzavi, J.; Czerny, C.

    1997-01-01

    In the last decade, the rehabilitation of postlingually deaf adults and prelingually deaf children with cochlear implants has been established as a treatment of deafness. The technological development of the implant devices and improvement of the surgical technique have led to a considerable increase of hearing performance during the last years. The postlingually deaf adults are able to use the telephone and may be integrated in their original job. Prelingually deaf children can even visit normal schools after cochlear implantation and hearing rehabilitation training. In order to preoperatively establish the state of the cochlear, radiological diagnosis of the temporal bone is necessary. High resolution computerized tomography imaging of the temporal bone with coronar and axial 1 mm slices and MRI with thin slice technique (three dimensional, T2 weighted turbo-spinecho sequence with 0.7 mm slices) have proved to be valuable according to our experience. Furthermore a postoperative synoptical X-ray, in a modified Chausse III projection, offers good information about the position of the implant and insertion of the stimulating electrode into the cochlea. (orig.) [de

  14. Cochlear implantation for severe sensorineural hearing loss caused by lightning.

    Science.gov (United States)

    Myung, Nam-Suk; Lee, Il-Woo; Goh, Eui-Kyung; Kong, Soo-Keun

    2012-01-01

    Lightning strike can produce an array of clinical symptoms and injuries. It may damage multiple organs and cause auditory injuries ranging from transient hearing loss and vertigo to complete disruption of the auditory system. Tympanic-membrane rupture is relatively common in patients with lightning injury. The exact pathogenetic mechanisms of auditory lesions in lightning survivors have not been fully elucidated. We report the case of a 45-year-old woman with bilateral profound sensorineural hearing loss caused by a lightning strike, who was successfully rehabilitated after a cochlear implantation. Copyright © 2012 Elsevier Inc. All rights reserved.

  15. Aspects of Music with Cochlear Implants – Music Listening Habits and Appreciation in Danish Cochlear Implant Users

    DEFF Research Database (Denmark)

    Petersen, Bjørn; Hansen, Mads; Sørensen, Stine Derdau

    Cochlear implant users differ significantly from their normal hearing peers when it comes to perception of music. Several studies have shown that structural features – such as rhythm, timbre, and pitch – are transmitted less accurately through an implant. However, we cannot predict personal...... music less post-implantation than prior to their hearing loss. Nevertheless, a large majority of CI listeners either prefer music over not hearing music at all or find music as pleasant as they recall it before their hearing loss, or more so....... enjoyment of music solely as a function of accuracy of perception. But can music be pleasant with a cochlear implant at all? Our aim here was to gather information of both music enjoyment and listening habits before the onset of hearing loss and post-operation from a large, representative sample of Danish...

  16. Survey of the American Neurotology Society on Cochlear Implantation: Part 1, Candidacy Assessment and Expanding Indications.

    Science.gov (United States)

    Carlson, Matthew L; Sladen, Douglas P; Gurgel, Richard K; Tombers, Nicole M; Lohse, Christine M; Driscoll, Colin L

    2018-01-01

    . Nineteen (26%) solely used +10 dB signal-to-noise ratio (SNR), 12 (16%) solely used +5 dB SNR, and 41 (55%) used both +10 and +5 dB SNR. Overall, 19% (N = 14) only perform unilateral implantation in the Medicare population, while 81% (N = 58) consider bilateral implantation. Significant variation in cochlear implant candidacy assessment and off-label implantation exists across centers and providers in the United States resulting in healthcare inequities. The high percentage of surgeons performing implantations for off-label or nontraditional indications reflects the overly restrictive and dated status of current implant guidelines. With greater adoption of more difficult speech perception testing in noise, careful clinical judgment is needed to maintain a favorable risk-benefit balance for prospective implant candidates.

  17. Prevalence of inner ear anomalies among cochlear implant candidates.

    Science.gov (United States)

    Aldhafeeri, Ahmad M; Alsanosi, Abdulrahman A

    2016-10-01

    To determine the prevalence of inner ear anomalies and the frequency of different anomaly types among cochlear implant recipients. This study included a retrospective chart review of all patients who received cochlear implants between January 2009 and January 2013 in King Abdulaziz University Hospital cochlear implant program in Riyadh, Saudi Arabia. All subjects underwent thin-cut CT of the temporal bone and MRI. The collected data included age, gender, and CT and MRI findings regarding temporal bone anomalies. Patients with any identified congenital inner ear anomalies were included in the study.  In total, 316 patients' cases were reviewed. Inner ear malformations were identified in 24 patients, which represented a prevalence of 7.5%. Among these 24 patients, 8 (33.3%) presented with a large vestibular aqueduct (LVA), 8 (33.3%) semicircular canal (SCC) dysplasia, 7 (29.1%) classical Mondini deformity, and one (4.1%) cochlear hypoplasia. The prevalence of inner ear anomalies among cochlear implant recipients was 7.5%. This result is consistent with findings worldwide. The most common anomalies were LVA and SCC hypoplasia; by contrast, in other regions, the most common anomaly is either the Mondini deformity, or LVA.

  18. [Cochlear implants in the social courts].

    Science.gov (United States)

    Lottner, A; Iro, H; Schützenberger, A; Hoppe, U

    2018-02-01

    Since the indication for receiving a cochlear implant (CI) has widened (single-sided deafness [SSD], electric acoustic stimulation [EAS], bilateral CI, CI for long-term deafness), more and more patients come into consideration for such a treatment. Hence, disputes increasingly arise between patients and their insurance companies concerning the question of whether surgery and follow-up treatment have to be paid for by statutory health insurance. This work provides an overview of judgments rendered by the German social courts. We investigated whether and in which cases it is advisable for a patient to go to court, and how long the proceedings may take. We looked for judgments in the two biggest commercial legal databases and in the database of the German social courts, using combinations of the search parameters "Cochlear," "Cochlea," "Implant," and "Implantat." Three verdicts were attained by directly contacting the court; another one was mentioned in an article. The reviewed judgements were issued between 2003 and 2017. A total of 12 judgments were found. The patients won in all but one of the main proceedings. The case that was lost concerned exceptional circumstances. One patient didn't get the desired interim measure, but won in the main proceedings. The proceedings took between 1 year and 8 months, and 9 years and 5 months. Despite the amount of time the patient has to invest, taking legal action is worthwhile. The proceedings at the social courts are generally exempt from charges. In most cases, the statutory health insurance is ordered to pay for a CI.

  19. Auditory Cortical Maturation in a Child with Cochlear Implant: Analysis of Electrophysiological and Behavioral Measures

    Directory of Open Access Journals (Sweden)

    Liliane Aparecida Fagundes Silva

    2015-01-01

    Full Text Available The purpose of this study was to longitudinally assess the behavioral and electrophysiological hearing changes of a girl inserted in a CI program, who had bilateral profound sensorineural hearing loss and underwent surgery of cochlear implantation with electrode activation at 21 months of age. She was evaluated using the P1 component of Long Latency Auditory Evoked Potential (LLAEP; speech perception tests of the Glendonald Auditory Screening Procedure (GASP; Infant Toddler Meaningful Auditory Integration Scale (IT-MAIS; and Meaningful Use of Speech Scales (MUSS. The study was conducted prior to activation and after three, nine, and 18 months of cochlear implant activation. The results of the LLAEP were compared with data from a hearing child matched by gender and chronological age. The results of the LLAEP of the child with cochlear implant showed gradual decrease in latency of the P1 component after auditory stimulation (172 ms–134 ms. In the GASP, IT-MAIS, and MUSS, gradual development of listening skills and oral language was observed. The values of the LLAEP of the hearing child were expected for chronological age (132 ms–128 ms. The use of different clinical instruments allow a better understanding of the auditory habilitation and rehabilitation process via CI.

  20. Auditory Cortical Maturation in a Child with Cochlear Implant: Analysis of Electrophysiological and Behavioral Measures

    Science.gov (United States)

    Silva, Liliane Aparecida Fagundes; Couto, Maria Inês Vieira; Tsuji, Robinson Koji; Bento, Ricardo Ferreira; de Carvalho, Ana Claudia Martinho; Matas, Carla Gentile

    2015-01-01

    The purpose of this study was to longitudinally assess the behavioral and electrophysiological hearing changes of a girl inserted in a CI program, who had bilateral profound sensorineural hearing loss and underwent surgery of cochlear implantation with electrode activation at 21 months of age. She was evaluated using the P1 component of Long Latency Auditory Evoked Potential (LLAEP); speech perception tests of the Glendonald Auditory Screening Procedure (GASP); Infant Toddler Meaningful Auditory Integration Scale (IT-MAIS); and Meaningful Use of Speech Scales (MUSS). The study was conducted prior to activation and after three, nine, and 18 months of cochlear implant activation. The results of the LLAEP were compared with data from a hearing child matched by gender and chronological age. The results of the LLAEP of the child with cochlear implant showed gradual decrease in latency of the P1 component after auditory stimulation (172 ms–134 ms). In the GASP, IT-MAIS, and MUSS, gradual development of listening skills and oral language was observed. The values of the LLAEP of the hearing child were expected for chronological age (132 ms–128 ms). The use of different clinical instruments allow a better understanding of the auditory habilitation and rehabilitation process via CI. PMID:26881163

  1. Microphone directionality, pre-emphasis filter, and wind noise in cochlear implants.

    Science.gov (United States)

    Chung, King; McKibben, Nicholas

    2011-10-01

    Wind noise can be a nuisance or a debilitating masker for cochlear implant users in outdoor environments. Previous studies indicated that wind noise at the microphone/hearing aid output had high levels of low-frequency energy and the amount of noise generated is related to the microphone directionality. Currently, cochlear implants only offer either directional microphones or omnidirectional microphones for users at-large. As all cochlear implants utilize pre-emphasis filters to reduce low-frequency energy before the signal is encoded, effective wind noise reduction algorithms for hearing aids might not be applicable for cochlear implants. The purposes of this study were to investigate the effect of microphone directionality on speech recognition and perceived sound quality of cochlear implant users in wind noise and to derive effective wind noise reduction strategies for cochlear implants. A repeated-measure design was used to examine the effects of spectral and temporal masking created by wind noise recorded through directional and omnidirectional microphones and the effects of pre-emphasis filters on cochlear implant performance. A digital hearing aid was programmed to have linear amplification and relatively flat in-situ frequency responses for the directional and omnidirectional modes. The hearing aid output was then recorded from 0 to 360° at flow velocities of 4.5 and 13.5 m/sec in a quiet wind tunnel. Sixteen postlingually deafened adult cochlear implant listeners who reported to be able to communicate on the phone with friends and family without text messages participated in the study. Cochlear implant users listened to speech in wind noise recorded at locations that the directional and omnidirectional microphones yielded the lowest noise levels. Cochlear implant listeners repeated the sentences and rated the sound quality of the testing materials. Spectral and temporal characteristics of flow noise, as well as speech and/or noise characteristics before

  2. Are parents of children with cochlear implants coping?: research ...

    African Journals Online (AJOL)

    Many variables must be considered during the evaluation and rehabilitation of children for cochlear implantation, one of which is parental influence (for the duration of this report the parents, caregivers and guardians of children with cochlear implants and / or hearing impairments will be referred to as 'parents'). The aim of ...

  3. The Relationship Between Intensity Coding and Binaural Sensitivity in Adults With Cochlear Implants.

    Science.gov (United States)

    Todd, Ann E; Goupell, Matthew J; Litovsky, Ruth Y

    Many bilateral cochlear implant users show sensitivity to binaural information when stimulation is provided using a pair of synchronized electrodes. However, there is large variability in binaural sensitivity between and within participants across stimulation sites in the cochlea. It was hypothesized that within-participant variability in binaural sensitivity is in part affected by limitations and characteristics of the auditory periphery which may be reflected by monaural hearing performance. The objective of this study was to examine the relationship between monaural and binaural hearing performance within participants with bilateral cochlear implants. Binaural measures included dichotic signal detection and interaural time difference discrimination thresholds. Diotic signal detection thresholds were also measured. Monaural measures included dynamic range and amplitude modulation detection. In addition, loudness growth was compared between ears. Measures were made at three stimulation sites per listener. Greater binaural sensitivity was found with larger dynamic ranges. Poorer interaural time difference discrimination was found with larger difference between comfortable levels of the two ears. In addition, poorer diotic signal detection thresholds were found with larger differences between the dynamic ranges of the two ears. No relationship was found between amplitude modulation detection thresholds or symmetry of loudness growth and the binaural measures. The results suggest that some of the variability in binaural hearing performance within listeners across stimulation sites can be explained by factors nonspecific to binaural processing. The results are consistent with the idea that dynamic range and comfortable levels relate to peripheral neural survival and the width of the excitation pattern which could affect the fidelity with which central binaural nuclei process bilateral inputs.

  4. The impact of ethnicity on cochlear implantation in Norwegian children.

    Science.gov (United States)

    Amundsen, Viktoria Vedeler; Wie, Ona Bø; Myhrum, Marte; Bunne, Marie

    2017-02-01

    To explore the impact of parental ethnicity on cochlear implantation in children in Norway with regard to incidence rates of cochlear implants (CIs), comorbidies, age at onset of profound deafness (AOD), age at first implantation, uni- or bilateral CI, and speech recognition. This retrospective cohort study included all children (N = 278) aged Nordic ethnicity, of whom 46 were born in Nordic countries with two non-Nordic parents. Compared with the background population, children with non-Nordic parents were 1.9 times more likely to have received CI than Nordic children (i.e., born in Nordic countries with Nordic parents). When looking at AOD, uni-vs. bilateral CIs, and comorbidities, no significant differences were found between Nordic children and children with a non-Nordic ethnicity. Among children with AOD Nordic countries with two non-Nordic parents (n = 6) and adopted non-Nordic children (n = 6) received their first CI on average 14.9 and 21.1 months later than Nordic children (n = 104), respectively (p = 0.006 and 0.005). Among children with AOD Nordic countries with two non-Nordic parents (n = 31) received their CI at an older age than Nordic children, but this difference was not significant after adjusting for calendar year of implantation and excluding comorbidity as a potential cause of delayed implantation. The mean age at implantation for children with AOD Nordic children and 76.3% for children born in Norway with two non-Nordic parents (p = 0.002). The incidence of CI was significantly higher in children with a non-Nordic vs. a Nordic ethnicity, reflecting a higher incidence of profound deafness. Children born in Norway have equal access to CIs regardless of their ethnicity, but despite being born and receiving care in Norway, prelingually deaf children with non-Nordic parents are at risk of receiving CI later than Nordic children. Moreover, prelingually deaf children who arrive in Norway at an older age may be at risk for a worse

  5. Experiments on Auditory-Visual Perception of Sentences by Users of Unilateral, Bimodal, and Bilateral Cochlear Implants

    Science.gov (United States)

    Dorman, Michael F.; Liss, Julie; Wang, Shuai; Berisha, Visar; Ludwig, Cimarron; Natale, Sarah Cook

    2016-01-01

    Purpose: Five experiments probed auditory-visual (AV) understanding of sentences by users of cochlear implants (CIs). Method: Sentence material was presented in auditory (A), visual (V), and AV test conditions to listeners with normal hearing and CI users. Results: (a) Most CI users report that most of the time, they have access to both A and V…

  6. Cochlear implant: what the radiologist should know

    Directory of Open Access Journals (Sweden)

    Natalia Delage Gomes

    2013-06-01

    Full Text Available Cochlear implant is the method of choice in the treatment of deep sensorineural hypoacusis, particularly in patients where conventional amplification devices do not imply noticeable clinical improvement. Imaging findings are crucial in the indication or contraindication for such surgical procedure. In the assessment of the temporal bone, radiologists should be familiar with relative or absolute contraindication factors, as well as with factors that might significantly complicate the implantation. Some criteria such as cochlear nerve aplasia, labyrinthine and/or cochlear aplasia are still considered as absolute contraindications, in spite of studies bringing such criteria into question. Cochlear dysplasias constitute relative contraindications, among them labyrinthitis ossificans is highlighted. Other alterations may be mentioned as complicating agents in the temporal bone assessment, namely, hypoplasia of the mastoid process, aberrant facial nerve, otomastoiditis, otosclerosis, dehiscent jugular bulb, enlarged endolymphatic duct and sac. The experienced radiologist assumes an important role in the evaluation of this condition.

  7. Cochlear implant: what the radiologist should know

    International Nuclear Information System (INIS)

    Gomes, Natalia Delage; Couto, Caroline Laurita Batista; Gaiotti, Juliana Oggioni; Costa, Ana Maria Doffemond; Ribeiro, Marcelo Almeida; Diniz, Renata Lopes Furletti Caldeira

    2013-01-01

    Cochlear implant is the method of choice in the treatment of deep sensorineural hypoacusis, particularly in patients where conventional amplification devices do not imply noticeable clinical improvement. Imaging findings are crucial in the indication or contraindication for such surgical procedure. In the assessment of the temporal bone, radiologists should be familiar with relative or absolute contraindication factors, as well as with factors that might significantly complicate the implantation. Some criteria such as cochlear nerve aplasia, labyrinthine and/or cochlear aplasia are still considered as absolute contraindications, in spite of studies bringing such criteria into question. Cochlear dysplasias constitute relative contraindications, among them labyrinthitis ossificans is highlighted. Other alterations may be mentioned as complicating agents in the temporal bone assessment, namely, hypoplasia of the mastoid process, aberrant facial nerve, otomastoiditis, otosclerosis, dehiscent jugular bulb, enlarged endolymphatic duct and sac. The experienced radiologist assumes an important role in the evaluation of this condition. (author)

  8. Music Therapy for Preschool Cochlear Implant Recipients

    Science.gov (United States)

    Gfeller, Kate; Driscoll, Virginia; Kenworthy, Maura; Van Voorst, Tanya

    2010-01-01

    This paper provides research and clinical information relevant to music therapy for preschool children who use cochlear implants (CI). It consolidates information from various disciplinary sources regarding (a) cochlear implantation of young prelingually-deaf children (~age 2-5), (b) patterns of auditory and speech-language development, and (c) research regarding music perception of children with CIs. This information serves as a foundation for the final portion of the article, which describes typical music therapy goals and examples of interventions suitable for preschool children. PMID:23904691

  9. Hearing Preservation in Cochlear Implant Surgery

    Directory of Open Access Journals (Sweden)

    Priscila Carvalho Miranda

    2014-01-01

    Full Text Available In the past, it was thought that hearing loss patients with residual low-frequency hearing would not be good candidates for cochlear implantation since insertion was expected to induce inner ear trauma. Recent advances in electrode design and surgical techniques have made the preservation of residual low-frequency hearing achievable and desirable. The importance of preserving residual low-frequency hearing cannot be underestimated in light of the added benefit of hearing in noisy atmospheres and in music quality. The concept of electrical and acoustic stimulation involves electrically stimulating the nonfunctional, high-frequency region of the cochlea with a cochlear implant and applying a hearing aid in the low-frequency range. The principle of preserving low-frequency hearing by a “soft surgery” cochlear implantation could also be useful to the population of children who might profit from regenerative hair cell therapy in the future. Main aspects of low-frequency hearing preservation surgery are discussed in this review: its brief history, electrode design, principles and advantages of electric-acoustic stimulation, surgical technique, and further implications of this new treatment possibility for hearing impaired patients.

  10. Computational tool for postoperative evaluation of cochlear implant patients

    International Nuclear Information System (INIS)

    Giacomini, Guilherme; Pavan, Ana Luiza M.; Pina, Diana R. de; Altemani, Joao M.C.; Castilho, Arthur M.

    2016-01-01

    The aim of this study was to develop a tool to calculate the insertion depth angle of cochlear implants, from computed tomography exams. The tool uses different image processing techniques, such as thresholding and active contour. Then, we compared the average insertion depth angle of three different implant manufacturers. The developed tool can be used, in the future, to compare the insertion depth angle of the cochlear implant with postoperative response of patient's hearing. (author)

  11. COCHLEAR IMPLANTATION IN A PATIENT WITH USHER'S SYNDROME

    OpenAIRE

    Derinsu, Ufuk; Ciprut, Ayca

    2016-01-01

    Usher's Syndrome is an autosomal recessive disorder characterized by congenital hearing loss and retinitis pigmentosa. Usher’s Syndrome patients with severe to profound sensorineural hearing loss can be considered as candidates for cochlear implantation.This case study reports a deaf-blind with Usher's Syndrome who received a cochlear implant, the audiological evaluation is presented and the therapy sessions are discussed. The patient demonstrated good performance overtime after the...

  12. Emotion Understanding in Deaf Children with a Cochlear Implant

    Science.gov (United States)

    Wiefferink, Carin H.; Rieffe, Carolien; Ketelaar, Lizet; De Raeve, Leo; Frijns, Johan H. M.

    2013-01-01

    It is still largely unknown how receiving a cochlear implant affects the emotion understanding in deaf children. We examined indices for emotion understanding and their associations with communication skills in children aged 2.5-5 years, both hearing children (n = 52) and deaf children with a cochlear implant (n = 57). 2 aspects of emotion…

  13. Simplifying cochlear implant speech processor fitting

    NARCIS (Netherlands)

    Willeboer, C.

    2008-01-01

    Conventional fittings of the speech processor of a cochlear implant (CI) rely to a large extent on the implant recipient's subjective responses. For each of the 22 intracochlear electrodes the recipient has to indicate the threshold level (T-level) and comfortable loudness level (C-level) while

  14. Labyrinthectomy with cochlear implantation.

    Science.gov (United States)

    Zwolan, T A; Shepard, N T; Niparko, J K

    1993-05-01

    Numerous reports indicate that the cochlea remains responsive to electrical stimulation following labyrinthectomy. We report a case of a 47-year-old woman with a severe to profound sensorineural hearing loss from birth, who developed episodic vertigo with symptoms suggestive of delayed onset endolymphatic hydrops. Following 8 months of failed medical and vestibular rehabilitation management, a right-sided labyrinthectomy combined with cochlear implantation was performed without complication. Postoperatively the patient was free of vertigo. Attempts to activate the patient's device between 4 to 12 weeks after surgery were unsuccessful as stimulation of the electrodes resulted in discomfort. However, all 20 electrodes elicited comfortable hearing sensations 16 weeks postsurgery. One year after the successful activation, the patient demonstrated improved sound awareness and speech recognition with the implant when compared with preoperative performance with a hearing aid. This case study suggests that electrical detection thresholds with prosthetic stimulation may be unstable in the recently labyrinthectomized ear but supports and extends prior observations of preserved cochlear responsiveness after labyrinthectomy.

  15. Cochlear implantation in the world's largest medical device market: utilization and awareness of cochlear implants in the United States.

    Science.gov (United States)

    Sorkin, Donna L

    2013-03-01

    Provision of cochlear implants (CIs) for those within the criteria for implantation remains lower in the United States than in some other developed nations. When adults and children are grouped together, the rate of utilization/provision remains low at around 6%. For children, the provision rate is about 50% of those who could benefit from an implant, compared with figures of about 90% for the Flanders part of Belgium, the United Kingdom and other European countries. The probable reasons for this underprovision include: low awareness of the benefits of CIs among the population; low awareness among health-care professionals; the lack of specific referral pathways; some political issues relating to the Deaf Community; and financial issues related to health provision. Such financial issues result in situations which either fail to provide for access to implants or provide too low a level of the necessary funding, especially for low-income individuals covered by public health-care programs such as Medicaid. These issues might be mitigated by adoption and publication of standards for best clinical practices for CI provision, availability of current cost-effectiveness data, and the existence of an organization dedicated to cochlear implantation. Such an organization, the American Cochlear Implant Alliance (ACI Alliance), was recently organized and is described in the paper by Niparko et al. in this Supplement.

  16. [Pre-operation evaluation and intra-operation management of cochlear implantation].

    Science.gov (United States)

    Zhang, Dao-xing; Hu, Bao-hua; Xiao, Yu-li; Shi, Bo-ning

    2004-10-01

    To summarize pre-operation evaluation experiences in cochlear implantation. Performing auditory evaluation and image analysis seriously in 158 severe hearing loss or total deaf cases before cochlear implantation, comparing their performance with the findings during and post operation. Among the total 158 cases, 116 cases with normal structure, 42 cases with the abnormal findings of the inner or middle ear. Stapedial gusher happened in 6 cases, 1 case was not predicted before operation. Except 1 case with serious malformation, the findings of other 157 cases in operation were consistent with the pre-operation evaluation. We helped all patients reconstruct auditory conduction with cochlear implantation, and the average hearing level up to 37.6 dB SPL. Performing image analysis seriously before operation and planning for operation according to HRCT can do great help to cochlear implantation. The operation under the HRCT instruction has less complications.

  17. Congenitally Deafblind Children and Cochlear Implants: Effects on Communication

    Science.gov (United States)

    Dammeyer, Jesper

    2009-01-01

    There has been much research conducted demonstrating the positive benefits of cochlear implantation (CI) in children who are deaf. Research on CI in children who are both deaf and blind, however, is lacking. The purpose of this article is to present a study of five congenitally deafblind children who received cochlear implants between 2.2 and 4.2…

  18. Cochlear implant: the family's perspective.

    Science.gov (United States)

    Vieira, Sheila de Souza; Dupas, Giselle; Chiari, Brasilia Maria

    2018-07-01

    To understand the family's experience of a child who uses a cochlear implant (CI). Specifically, to identify the difficulties, changes, and feelings entailed by deafness and the use of the CI; the coping strategies; and to understand the role of the family for the child with a CI. Qualitative research, using Symbolic Interactionism and Straussian Grounded Theory as the theoretical and methodological frameworks, respectively. Data collection instrument: semi-structured interview. A total of 9 families (32 individuals) participated in the study. The children's ages ranged from 6 to 11 years old (mean = 8.9 years old). Their experience is described in the following categories: Having to fight for results, Coping with difficult situations, Recognizing that you are not alone, Learning to overcome, and Having one's life restored by the implant. Cochlear implantation changes the direction of the child and the family's life by restoring the child's opportunity to hear and to obtain good results in her personal, social, and academic development. Even after implantation, the child continues to experience difficulties and requires the family's mobilization in order to be successful. The family is the principal actor in the process of the child's rehabilitation.

  19. Effects of residual hearing on cochlear implant outcomes in children: A systematic-review.

    Science.gov (United States)

    Chiossi, Julia Santos Costa; Hyppolito, Miguel Angelo

    2017-09-01

    to investigate if preoperative residual hearing in prelingually deafened children can interfere on cochlear implant indication and outcomes. a systematic-review was conducted in five international databases up to November-2016, to locate articles that evaluated cochlear implantation in children with some degree of preoperative residual hearing. Outcomes were auditory, language and cognition performances after cochlear implant. The quality of the studies was assessed and classified according to the Oxford Levels of Evidence table - 2011. Risk of biases were also described. From the 30 articles reviewed, two types of questions were identified: (a) what are the benefits of cochlear implantation in children with residual hearing? (b) is the preoperative residual hearing a predictor of cochlear implant outcome? Studies ranged from 04 to 188 subjects, evaluating populations between 1.8 and 10.3 years old. The definition of residual hearing varied between studies. The majority of articles (n = 22) evaluated speech perception as the outcome and 14 also assessed language and speech production. There is evidence that cochlear implant is beneficial to children with residual hearing. Preoperative residual hearing seems to be valuable to predict speech perception outcomes after cochlear implantation, even though the mechanism of how it happens is not clear. More extensive researches must be conducted in order to make recommendations and to set prognosis for cochlear implants based on children preoperative residual hearing. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Scala vestibuli cochlear implantation in patients with partially ossified cochleas.

    Science.gov (United States)

    Berrettini, Stefano; Forli, Francesca; Neri, Emanuele; Segnini, Giovanni; Franceschini, Stefano Sellari

    2002-11-01

    Partial cochlear obstruction is a relatively common finding in candidates for cochlear implants and frequently involves the inferior segment of the scala tympani in the basal turn of the cochlea. In such patients, the scala vestibuli is often patent and offers an alternative site for implantation. The current report describes two patients with such partial obstruction of the inferior segment of the basal cochlear turn, caused in one case by systemic vasculitis (Takayasu's disease) and in the other by obliterative otosclerosis. A scala vestibuli implantation allowed for complete insertion of the electrode array. No problems were encountered during the surgical procedures and the good post-operative hearing and communicative outcomes achieved were similar to those reported in patients without cochlear ossification. The importance of accurate pre-operative radiological study of the inner ear is underscored, to disclose the presence and define the features of the cochlear ossification and ultimately to properly plan the surgical approach.

  1. Systematic review: Radiological and histological evidence of cochlear implant insertion trauma in adult patients.

    Science.gov (United States)

    Hoskison, Emma; Mitchell, Scott; Coulson, Chris

    2017-07-01

    Cochlear implantation (CI) has developed from its origins in the 1980s. Initially, CI was for profound bilateral hearing impairment. However, candidacy for CI have become more widespread in recent years with unilateral implantation and an emphasis on hearing preservation. Evidence supports full electrode insertion in an atraumatic fashion into the scala tympani (ST) provides optimal hearing outcomes. The main aim of this systematic review was to elucidate the degree of trauma associated with CI insertion. A systematic literature search was undertaken using PubMed Medline. A grading system described by Eshraghi was used to classify cochlear trauma. Both radiological and histological studies were included. Twenty one papers were identified which were relevant to our search. In total, 653 implants were inserted and 115 (17.6%) showed evidence of trauma. The cochleas with trauma had basilar membrane elevation in 5.2%, ruptured in 5.2%, the electrode passed from the ST to the SV in 84.4% and there was grade 4 trauma in 5.2%. The studies used a variety of histological and radiological methods to assess for evidence of trauma in both cadaveric temporal bones and live recipients. Minimizing cochlear trauma during implant insertion is important to preserve residual hearing and optimize audiological performance. An overall 17.6% trauma rate suggests that CI insertion could be improved with more accurate and consistent electrode insertion such as in the form of robotic guidance. The correlation of cochlea trauma with post-operative hearing has yet to be determined.

  2. Meningitis after cochlear implantation in Mondini malformation.

    Science.gov (United States)

    Page, E L; Eby, T L

    1997-01-01

    Although the potential for CSF leakage and subsequent meningitis after cochlear implantation in the malformed cochlea has been recognized, this complication has not been previously reported. We report a case of CSF otorhinorrhea and meningitis after minor head trauma developing 2 years after cochlear implantation in a child with Mondini malformation. Leakage of CSF was identified from the cochleostomy around the electrode of the implant, and this leak was sealed with a temporalis fascia and muscle plug. Although this complication appears to be rare, care must be taken to seal the cochleostomy in children with inner ear malformations at the initial surgery, and any episode of meningitis after surgery must be thoroughly investigated to rule out CSF leakage from the labyrinth.

  3. Effects of a Word-Learning Training on Children With Cochlear Implants

    Science.gov (United States)

    Lund, Emily

    2014-01-01

    Preschool children with hearing loss who use cochlear implants demonstrate vocabulary delays when compared to their peers without hearing loss. These delays may be a result of deficient word-learning abilities; children with cochlear implants perform more poorly on rapid word-learning tasks than children with normal hearing. This study explored the malleability of rapid word learning of preschoolers with cochlear implants by evaluating the effects of a word-learning training on rapid word learning. A single-subject, multiple probe design across participants measured the impact of the training on children’s rapid word-learning performance. Participants included 5 preschool children with cochlear implants who had an expressive lexicon of less than 150 words. An investigator guided children to identify, repeat, and learn about unknown sets of words in 2-weekly sessions across 10 weeks. The probe measure, a rapid word-learning task with a different set of words than those taught during training, was collected in the baseline, training, and maintenance conditions. All participants improved their receptive rapid word-learning performance in the training condition. The functional relation indicates that the receptive rapid word-learning performance of children with cochlear implants is malleable. PMID:23981321

  4. Visualization of spiral ganglion neurites within the scala tympani with a cochlear implant in situ.

    Science.gov (United States)

    Chikar, Jennifer A; Batts, Shelley A; Pfingst, Bryan E; Raphael, Yehoash

    2009-05-15

    Current cochlear histology methods do not allow in situ processing of cochlear implants. The metal components of the implant preclude standard embedding and mid-modiolar sectioning, and whole mounts do not have the spatial resolution needed to view the implant within the scala tympani. One focus of recent auditory research is the regeneration of structures within the cochlea, particularly the ganglion cells and their processes, and there are multiple potential benefits to cochlear implant users from this work. To facilitate experimental investigations of auditory nerve regeneration performed in conjunction with cochlear implantation, it is critical to visualize the cochlear tissue and the implant together to determine if the nerve has made contact with the implant. This paper presents a novel histological technique that enables simultaneous visualization of the in situ cochlear implant and neurofilament-labeled nerve processes within the scala tympani, and the spatial relationship between them.

  5. Impact of socioeconomic factors on paediatric cochlear implant outcomes.

    Science.gov (United States)

    Sharma, Shalabh; Bhatia, Khyati; Singh, Satinder; Lahiri, Asish Kumar; Aggarwal, Asha

    2017-11-01

    The study was aimed at evaluating the impact of certain socioeconomic factors such as family income, level of parents' education, distance between the child's home and auditory verbal therapy clinic, and age of the child at implantation on postoperative cochlear implant outcomes. Children suffering from congenital bilateral profound sensorineural hearing loss and a chronologic age of 4 years or younger at the time of implantation were included in the study. Children who were able to complete a prescribed period of a 1-year follow-up were included in the study. These children underwent cochlear implantation surgery, and their postoperative outcomes were measured and documented using categories of auditory perception (CAP), meaningful auditory integration (MAIS), and speech intelligibility rating (SIR) scores. Children were divided into three groups based on the level of parental education, family income, and distance of their home from the rehabilitation-- auditory verbal therapy clinic. A total of 180 children were studied. The age at implantation had a significant impact on the postoperative outcomes, with an inverse correlation. The younger the child's age at the time of implantation, the better were the postoperative outcomes. However, there were no significant differences among the CAP, MAIS, and SIR scores and each of the three subgroups. Children from families with an annual income of less than $7,500, between $7,500 and $15,000, and more than $15,000 performed equally well, except for significantly higher SIR scores in children with family incomes more than $15,000. Children with of parents who had attended high school or possessed a bachelor's or Master's master's degree had similar scores, with no significant difference. Also, distance from the auditory verbal therapy clinic failed to have any significantimpact on a child's performance. These results have been variable, similar to those of previously published studies. A few of the earlier studies

  6. Audiological findings after multichannel cochlear implantation in patients with Mondini dysplasia.

    Science.gov (United States)

    Munro, K J; George, C R; Haacke, N P

    1996-12-01

    Mondini dysplasia is a congenital malformation of the inner ear. To date, five individuals with this malformation have received cochlear implants at the South of England Cochlear Implant Centre. The aim of this study was to review the audiological findings of these individuals after implantation. The soundfield thresholds after implantation are in the region of 30-40 dB (A). The results of suprathreshold speech recognition tasks show substantial variability in performance but this is no greater than that obtained from implant users with no malformation. All individuals were able to detect and recognize a variety of environmental sounds that would previously have been inaudible. These findings, along with the reported improvement in quality of life, mean that Mondini dysplasia is not a contra-indication for multichannel cochlear implantation. This information will be useful to other centres when considering implantation in similar patients.

  7. Cochlear implant: Speech and language development in deaf and hard of hearing children following implantation

    Directory of Open Access Journals (Sweden)

    Ostojić Sanja

    2011-01-01

    Full Text Available Bacground/Aim. Almost 200 cochlear implantations were done in the four centers (two in Belgrade, per one in Novi Sad and Niš in Serbia from 2002 to 2009. Less than 10% of implantees were postlingually deaf adults. The vast majority, i.e. 90% were pre- and perilingually profoundly deaf children. The aim of this study was to assess the influence of improved auditory perception due to cochlear implantation on comprehension of abstract words in children as compared with hearing impaired children with conventional hearing aids and normal hearing children. Methods. Thirty children were enrolled in this study: 20 hearing impaired and 10 normal hearing. The vocabulary test was used. Results. The overall results for the whole test (100 words showed a significant difference in favor of the normal hearing as compared with hearing impaired children. The normal hearing children successfully described or defined 77.93% of a total of 100 words. Success rate for the cochlear implanted children was 26.87% and for the hearing impaired children with conventional hearing aids 20.32%. Conclusion. Testing for abstract words showed a statistically significant difference between the cochlear implanted and the hearing impaired children with hearing aids (Mann- Whitney U-test, p = 0.019 implying considerable advantage of cochlear implants over hearing aids regarding successful speech development in prelingually deaf children.

  8. Pre- and Postoperative Binaural Unmasking for Bimodal Cochlear Implant Listeners.

    Science.gov (United States)

    Sheffield, Benjamin M; Schuchman, Gerald; Bernstein, Joshua G W

    Cochlear implants (CIs) are increasingly recommended to individuals with residual bilateral acoustic hearing. Although new hearing-preserving electrode designs and surgical approaches show great promise, CI recipients are still at risk to lose acoustic hearing in the implanted ear, which could prevent the ability to take advantage of binaural unmasking to aid speech recognition in noise. This study examined the tradeoff between the benefits of a CI for speech understanding in noise and the potential loss of binaural unmasking for CI recipients with some bilateral preoperative acoustic hearing. Binaural unmasking is difficult to evaluate in CI candidates because speech perception in noise is generally too poor to measure reliably in the range of signal to noise ratios (SNRs) where binaural intelligibility level differences (BILDs) are typically observed (binaural benefit, 9 out of 10 listeners tested postoperatively had performance equal to or better than their best pre-CI performance. The listener who retained functional acoustic hearing in the implanted ear also demonstrated a preserved acoustic BILD postoperatively. Approximately half of the CI candidates in this study demonstrated preoperative binaural hearing benefits for audiovisual speech perception in noise. Most of these listeners lost their acoustic hearing in the implanted ear after surgery (using nonhearing-preservation techniques), and therefore lost access to this binaural benefit. In all but one case, any loss of binaural benefit was compensated for or exceeded by an improvement in speech perception with the CI. Evidence of a preoperative BILD suggests that certain CI candidates might further benefit from hearing-preservation surgery to retain acoustic binaural unmasking, as demonstrated for the listener who underwent hearing-preservation surgery. This test of binaural audiovisual speech perception in noise could serve as a diagnostic tool to identify CI candidates who are most likely to receive

  9. The Phonemic Awareness Skills of Cochlear Implant Children and Children with Normal Hearing in Primary School

    Directory of Open Access Journals (Sweden)

    Aliakbar Dashtelei

    2015-12-01

    Full Text Available Objectives: Phonemic awareness skills have a significant impact on children speech and language. The purpose of this study was investigating the phonemic awareness skills of children with cochlear implant and normal hearing peers in primary school. Methods: phonemic awareness subscales of phonological awareness test were administered to 30 children with cochlear implantation at the first to sixth grades of primary school and 30 children with normal hearing who were matched in age with cochlear implant group. All of children were between 6 to 11 years old. Children with cochlear implant had at least 1 to 2 years of implant experience and they were over 5 years when they receive implantation. Children with cochlear implant were selected from Special education centers in Tehran and children with normal hearing were recruited from primary schools in Tehran. The phonemic awareness skills were assessed in both groups. Results: The results showed that the Mean scores of phonemic awareness skills in cochlear implant children were significantly lower than children with normal hearing (P<.0001. Discussion: children with cochlear implant, despite Cochlear implantation prosthesis, had lower performance in phonemic awareness when compared with normal hearing children. Therefore, due to importance of phonemic awareness skills in learning of literacy skills, and defects of these skills in children with cochlear implant, these skills should be assessed carefully in children with cochlear implant and rehabilitative interventions should be considered.

  10. The Hearing Outcomes of Cochlear Implantation in Waardenburg Syndrome

    OpenAIRE

    Koyama, Hajime; Kashio, Akinori; Sakata, Aki; Tsutsumiuchi, Katsuhiro; Matsumoto, Yu; Karino, Shotaro; Kakigi, Akinobu; Iwasaki, Shinichi; Yamasoba, Tatsuya

    2016-01-01

    Objectives. This study aimed to determine the feasibility of cochlear implantation for sensorineural hearing loss in patients with Waardenburg syndrome. Method. A retrospective chart review was performed on patients who underwent cochlear implantation at the University of Tokyo Hospital. Clinical classification, genetic mutation, clinical course, preoperative hearing threshold, high-resolution computed tomography of the temporal bone, and postoperative hearing outcome were assessed. Result. F...

  11. Clinical outcomes of scala vestibuli cochlear implantation in children with partial labyrinthine ossification.

    Science.gov (United States)

    Lin, Yung-Song

    2009-03-01

    Cochlear implantation via the scala vestibuli is a viable approach in those with ossification in the scala tympani. With extended cochlear implant experience, there is no significant difference in the mapping parameters and auditory performance between those implanted via scala vestibuli and via scala tympani. To assess the clinical outcomes of cochlear implantation via scala vestibuli. In a cohort follow-up study, 11 prelingually deafened children who received cochlear implantation between age 3 and 10 years through the scala vestibuli served as participants. The mapping parameters (i.e. comfortable level (C), threshold level (T), dynamic range) and auditory performance of each participant were evaluated following initial cochlear implant stimulation, then at 3 month intervals for 2 years, then semi-annually. The follow-up period lasted for 9 years 9 months on average, with a minimum of 8 years 3 months. The clinical results of the mapping parameters and auditory performance of children implanted via the scala vestibuli were comparative to those who were implanted via the scala tympani. No balance problem was reported by any of these patients. One child exhibited residual low frequency hearing after implantation.

  12. Automatic Model Generation Framework for Computational Simulation of Cochlear Implantation.

    Science.gov (United States)

    Mangado, Nerea; Ceresa, Mario; Duchateau, Nicolas; Kjer, Hans Martin; Vera, Sergio; Dejea Velardo, Hector; Mistrik, Pavel; Paulsen, Rasmus R; Fagertun, Jens; Noailly, Jérôme; Piella, Gemma; González Ballester, Miguel Ángel

    2016-08-01

    Recent developments in computational modeling of cochlear implantation are promising to study in silico the performance of the implant before surgery. However, creating a complete computational model of the patient's anatomy while including an external device geometry remains challenging. To address such a challenge, we propose an automatic framework for the generation of patient-specific meshes for finite element modeling of the implanted cochlea. First, a statistical shape model is constructed from high-resolution anatomical μCT images. Then, by fitting the statistical model to a patient's CT image, an accurate model of the patient-specific cochlea anatomy is obtained. An algorithm based on the parallel transport frame is employed to perform the virtual insertion of the cochlear implant. Our automatic framework also incorporates the surrounding bone and nerve fibers and assigns constitutive parameters to all components of the finite element model. This model can then be used to study in silico the effects of the electrical stimulation of the cochlear implant. Results are shown on a total of 25 models of patients. In all cases, a final mesh suitable for finite element simulations was obtained, in an average time of 94 s. The framework has proven to be fast and robust, and is promising for a detailed prognosis of the cochlear implantation surgery.

  13. Reading skills after cochlear implantation

    NARCIS (Netherlands)

    Vermeulen, A.M.

    2007-01-01

    It has frequently been found that profoundly deaf children with conventional hearing aids have difficulties with the comprehension of written text. Cochlear Implants (CIs) were expected to enhance the reading comprehension of these profoundly deaf children because they provide auditory access to

  14. Long latency auditory evoked potentials in children with cochlear implants: systematic review.

    Science.gov (United States)

    Silva, Liliane Aparecida Fagundes; Couto, Maria Inês Vieira; Matas, Carla Gentile; Carvalho, Ana Claudia Martinho de

    2013-11-25

    The aim of this study was to analyze the findings on Cortical Auditory Evoked Potentials in children with cochlear implant through a systematic literature review. After formulation of research question and search of studies in four data bases with the following descriptors: electrophysiology (eletrofisiologia), cochlear implantation (implante coclear), child (criança), neuronal plasticity (plasticidade neuronal) and audiology (audiologia), were selected articles (original and complete) published between 2002 and 2013 in Brazilian Portuguese or English. A total of 208 studies were found; however, only 13 contemplated the established criteria and were further analyzed; was made data extraction for analysis of methodology and content of the studies. The results described suggest rapid changes in P1 component of Cortical Auditory Evoked Potentials in children with cochlear implants. Although there are few studies on the theme, cochlear implant has been shown to produce effective changes in central auditory path ways especially in children implanted before 3 years and 6 months of age.

  15. Dislocation of cochlear implant magnet as a complication following MRI.

    Science.gov (United States)

    Murtojärvi, Sarita; Salonen, Jaakko

    According to current best knowledge, an MRI scan can be performed for patients with cochlear implants. The warnings and recommendations of the implant manufacturers must be followed strictly to prevent complications, such as overheating, migration or demagnetization of the magnet in the implant. We report on a case of cochlear implant magnet dislocation as a complication for an MRI scan. The patient had a tight bandage around the head to hold the magnet in place as recommended by the manufacturer, but apparently the bandage was not in the correct place.

  16. Future technology in cochlear implants: assessing the benefit.

    Science.gov (United States)

    Briggs, Robert J S

    2011-05-01

    It has been over 50 years since Djourno and Eyries first attempted electric stimulation in a patient with deafness. Over this time, the Cochlear Implant (CI) has become not only remarkably successful, but increasingly complex. Although the basic components of the system still comprise an implanted receiver stimulator and electrode, externally worn speech processor, microphone, control system, and power source, there are now several alternative designs of these components with different attributes that can be variably combined to meet the needs of specific patient groups. Development by the manufacturers has been driven both by these various patient needs, and also by the desire to achieve technological superiority, or at least differentiation, ultimately in pursuit of market share. Assessment of benefit is the responsibility of clinicians. It is incumbent on both industry and clinicians to ensure appropriate, safe, and affordable introduction of new technology. For example, experience with the totally implanted cochlear implant (TIKI) has demonstrated that quality of hearing is the over-riding consideration for CI users. To date, improved hearing outcomes have been achieved by improvements in: speech processing strategies; microphone technology; pre-processing strategies; electrode placement; bilateral implantation; use of a hearing aid in the opposite ear (bimodal stimulation); and the combination of electric and acoustic stimulation in the same ear. The resulting expansion of CI candidacy, with more residual hearing, further improves the outcomes achieved. Largely facilitated by advances in electronic capability and computerization, it can be expected that these improvements will continue. However, marked variability of results still occurs and we cannot assure any individual patient of their outcome. Realistic goals for implementation of new technology include: improved hearing in noise and music perception; effective invisible hearing (no external apparatus

  17. Cochlear Implants Keep Twin Sisters Learning, Discovering Together

    Science.gov (United States)

    ... Current Issue Past Issues Special Section: Focus on Communication Cochlear Implants Past Issues / Fall 2008 Table of ... in noisy environments—a critical ability in a classroom. Before the second implant, Mia was pulling back ...

  18. Outcomes and special considerations of cochlear implantation in waardenburg syndrome.

    Science.gov (United States)

    Kontorinis, Georgios; Lenarz, Thomas; Giourgas, Alexandros; Durisin, Martin; Lesinski-Schiedat, Anke

    2011-08-01

    The objective of this study was a state-of-the-art analysis of cochlear implantation in patients with Waardenburg syndrome (WS). Twenty-five patients with WS treated with cochlear implants in our department from 1990 to 2010. The 25 patients with WS underwent 35 cochlear implantations. Hearing outcome was evaluated using HSM sentence test in 65 dB in quiet, Freiburg Monosyllabic Test, and categories of auditory performance for children and compared with that of a control group. Anatomic abnormalities of the inner ear were examined using magnetic resonance imaging and computed tomography of the temporal bones. The mean follow-up time was 8.3 years (range, 0.3-18.3 yr). The majority achieved favorable postimplantation performance with mean HSM scores of 75.3% (range, 22.6%-99%) and Freiburg Monosyllabic Test scores of 67.8% (range, 14%-95%). However, in 4 cases, the results were less satisfactory. The comparison with the control group did not reveal any statistical significance (p = 0.56). In 6 patients (24%), behavioral disorders caused temporary difficulties during the rehabilitation procedure. Except of isolated large vestibule in 1 patient, the radiological assessment of the 50 temporal bones did not reveal any temporal bone abnormalities. Most patients with WS performed well with cochlear implants. However, WS is related to behavioral disorders that may cause temporary rehabilitation difficulties. Finally, temporal bone malformations that could affect cochlear implantation are notcharacteristic of WS.

  19. American parent perspectives on quality of life in pediatric cochlear implant recipients.

    Science.gov (United States)

    Kumar, Roshini; Warner-Czyz, Andrea; Silver, Cheryl H; Loy, Betty; Tobey, Emily

    2015-01-01

    Cochlear implantation influences not only communication but also psychosocial outcomes in children with severe to profound hearing loss. Focusing on issues specific to cochlear implantation (e.g., self-reliance, social relations, education, effects of implantation, and supporting the child) may provide a more accurate and relative view of functional status of pediatric cochlear implant (CI) recipients. The present study analyzes parental perspectives of CI-specific health-related quality of life (HRQoL) in children with CIs to determine (a) if parents differentially rate their child's quality of life according to psychosocial domain (e.g., communication, self-reliance, education); (b) if associations exist between quality of life domains specific to cochlear implantation in pediatric implant recipients; and (c) if demographic variables (i.e., chronologic age, age at cochlear implantation, duration of device experience) mediate parent ratings of quality of life in pediatric CI recipients. Parents of 33 children with CIs (mean age, 9.85 years; mean age of CI activation, 2.47 years; mean device experience, 7.47 years) completed a validated condition-specific questionnaire, Children With Cochlear Implants: Parental Perspectives. Parents positively rated most HRQoL domains, although education and effects of implantation received significantly less positive ratings (p self-reliance, and well-being) significantly correlated with at least 5 other domains, suggesting that positivity in one domain co-occurs with positivity in other domains. Demographic variables (chronologic age, CI activation age, and duration of CI use) did not correlate significantly with psychosocial outcomes; rather, parents reported positive HRQoL and successful functional use of CI across demographic variables. Parents of children and adolescents with CIs rate overall HRQoL positively across psychosocial domains. Significantly less positive ratings of education and effects of implantation may result

  20. Evidence of across-channel processing for spectral-ripple discrimination in cochlear implant listeners.

    Science.gov (United States)

    Won, Jong Ho; Jones, Gary L; Drennan, Ward R; Jameyson, Elyse M; Rubinstein, Jay T

    2011-10-01

    Spectral-ripple discrimination has been used widely for psychoacoustical studies in normal-hearing, hearing-impaired, and cochlear implant listeners. The present study investigated the perceptual mechanism for spectral-ripple discrimination in cochlear implant listeners. The main goal of this study was to determine whether cochlear implant listeners use a local intensity cue or global spectral shape for spectral-ripple discrimination. The effect of electrode separation on spectral-ripple discrimination was also evaluated. Results showed that it is highly unlikely that cochlear implant listeners depend on a local intensity cue for spectral-ripple discrimination. A phenomenological model of spectral-ripple discrimination, as an "ideal observer," showed that a perceptual mechanism based on discrimination of a single intensity difference cannot account for performance of cochlear implant listeners. Spectral modulation depth and electrode separation were found to significantly affect spectral-ripple discrimination. The evidence supports the hypothesis that spectral-ripple discrimination involves integrating information from multiple channels. © 2011 Acoustical Society of America

  1. Language understanding and vocabulary of early cochlear implanted children

    DEFF Research Database (Denmark)

    Percy-Smith, L; Busch, GW; Sandahl, M

    2013-01-01

    The aim of the study was to identify factors associated with the level of language understanding, the level of receptive and active vocabulary, and to estimate effect-related odds ratios for cochlear implanted children's language level.......The aim of the study was to identify factors associated with the level of language understanding, the level of receptive and active vocabulary, and to estimate effect-related odds ratios for cochlear implanted children's language level....

  2. Psycholinguistic abilities in cochlear implant and hearing impaired children

    OpenAIRE

    Hassan, Hatem Ezzeldin; Eldin, Sally Taher Kheir; Al Kasaby, Rasha Mohamed

    2014-01-01

    Background: Many congenitally sensorineural hearing loss (SNHL) children and cochlear implant (CI) recipients develop near-normal language skills. However, there is a wide variation in individual outcomes following cochlear implantation, or using hearing aids. Some CI recipients or Hearing aids users never develop useable speech and oral language skills. The causes of this enormous variation in outcomes are only partly understood at the present time. So, the aim of this study was to assess th...

  3. Spatial channel interactions in cochlear implants

    Science.gov (United States)

    Tang, Qing; Benítez, Raul; Zeng, Fan-Gang

    2011-08-01

    The modern multi-channel cochlear implant is widely considered to be the most successful neural prosthesis owing to its ability to restore partial hearing to post-lingually deafened adults and to allow essentially normal language development in pre-lingually deafened children. However, the implant performance varies greatly in individuals and is still limited in background noise, tonal language understanding, and music perception. One main cause for the individual variability and the limited performance in cochlear implants is spatial channel interaction from the stimulating electrodes to the auditory nerve and brain. Here we systematically examined spatial channel interactions at the physical, physiological, and perceptual levels in the same five modern cochlear implant subjects. The physical interaction was examined using an electric field imaging technique, which measured the voltage distribution as a function of the electrode position in the cochlea in response to the stimulation of a single electrode. The physiological interaction was examined by recording electrically evoked compound action potentials as a function of the electrode position in response to the stimulation of the same single electrode position. The perceptual interactions were characterized by changes in detection threshold as well as loudness summation in response to in-phase or out-of-phase dual-electrode stimulation. To minimize potentially confounding effects of temporal factors on spatial channel interactions, stimulus rates were limited to 100 Hz or less in all measurements. Several quantitative channel interaction indexes were developed to define and compare the width, slope and symmetry of the spatial excitation patterns derived from these physical, physiological and perceptual measures. The electric field imaging data revealed a broad but uniformly asymmetrical intracochlear electric field pattern, with the apical side producing a wider half-width and shallower slope than the basal

  4. Productivity of lexical categories in French-speaking children with cochlear implants.

    Science.gov (United States)

    Le Normand, M-T; Ouellet, C; Cohen, H

    2003-11-01

    The productivity of lexical categories was studied longitudinally in a sample of 17 young hearing-impaired French-speaking children with cochlear implants. Age of implantation ranged from 22 months to 76 months. Spontaneous speech samples were collected at six-month intervals over a period of 36 months, starting at the one-word stage. Four general measures of their linguistic production (number of utterances, verbal fluency, vocabulary, and grammatical production) as well as 36 specific lexical categories, according to the CHILDES codes, were computed in terms of tokens, i.e., total number of words. Cochlear-implanted children (CI) were compared to a French database of normally hearing children aged 2-4 compiled by the first author. Follow-up results indicate that, at the two-year post-implantation follow-up, noun, and verb morphology was significantly impaired. At the three-year follow-up, the cochlear-implanted group had recovered on adjectives, determiners and nouns, main verbs, and auxiliaries. The two groups differed significantly in processing locative adverbs, prepositions, pronouns, and verbs (infinitive verb, modal, and modal lexical), but individual variability within the cochlear-implanted group was substantial. Results are discussed in terms of recovery and developmental trends and variability in the acquisition of lexical categories by French children two years and three years post-implantation.

  5. Staphylococcus lugdunensis: novel organism causing cochlear implant infection

    Directory of Open Access Journals (Sweden)

    Samina Bhumbra

    2014-06-01

    Full Text Available A majority of cochlear implant infections are caused by Staphylococcus aureus or Pseudomonas aeruginosa. Reported here is a pediatric patient with a cochlear implant infection caused by methicillin-resistant Staphylococcus lugdunensis, a coagulase-negative Staphylococcus that has only recently been determined to be clinically relevant (1988. Unlike other coagulase-negative Staphylococcus, it is more aggressive, carrying a greater potential for tissue destruction. In pediatrics, the organism is uncommon, poorly described, and generally pan-susceptible. Described herein is the presentation and management of this unusual organism in a pediatric setting.

  6. Cochlear implant with a non-removable magnet: preliminary research at 3-T MRI.

    Science.gov (United States)

    Dubrulle, F; Sufana Iancu, A; Vincent, C; Tourrel, G; Ernst, O

    2013-06-01

    To perform preliminary tests in vitro and with healthy volunteers to determine the 3-T MRI compatibility of a cochlear implant with a non-removable magnet. In the in vitro phase, we tested six implants for temperature changes and internal malfunctioning. We measured the demagnetisation of 65 internal magnets with different tilt angles between the implant's magnetic field (bi) and the main magnetic field (b0). In the in vivo phase, we tested 28 operational implants attached to the scalps of volunteers with the head in three different positions. The study did not find significant temperature changes or electronic malfunction in the implants tested in vitro. We found considerable demagnetisation of the cochlear implant magnets in the in vitro and in vivo testing influenced by the position of the magnet in the main magnetic field. We found that if the bi/b0 angle is 90°, there is demagnetisation in almost 60 % of the cases. When the angle is around 90°, the risk of demagnetisation is low (6.6 %). The preliminary results on cochlear implants with non-removable magnets indicate the need to maintain the contraindication of passage through 3-T MRI. • Magnetic resonance imaging can affect cochlear implants and vice versa. • Demagnetisation of cochlear implant correlates with the angle between bi and b0. • The position of the head in the MRI influences the demagnetisation. • Three-Tesla MRI for cochlear implants is still contraindicated. • However some future solutions are discussed.

  7. Cochlear implantation and change in quality of life

    DEFF Research Database (Denmark)

    Faber, Christian; Grøntved, Ågot Møller

    2000-01-01

    The aim of this study was to assess the benefits of cochlear implantation (CI) in adults and to evaluate the average implant usage per day. Ten profoundly deaf adults were implanted during the period April 1994 to September 1997. The patients answered questionnaires 1 year or more after receiving...

  8. Cochlear implants and spoken language processing abilities: review and assessment of the literature.

    Science.gov (United States)

    Peterson, Nathaniel R; Pisoni, David B; Miyamoto, Richard T

    2010-01-01

    Cochlear implants (CIs) process sounds electronically and then transmit electric stimulation to the cochlea of individuals with sensorineural deafness, restoring some sensation of auditory perception. Many congenitally deaf CI recipients achieve a high degree of accuracy in speech perception and develop near-normal language skills. Post-lingually deafened implant recipients often regain the ability to understand and use spoken language with or without the aid of visual input (i.e. lip reading). However, there is wide variation in individual outcomes following cochlear implantation, and some CI recipients never develop useable speech and oral language skills. The causes of this enormous variation in outcomes are only partly understood at the present time. The variables most strongly associated with language outcomes are age at implantation and mode of communication in rehabilitation. Thus, some of the more important factors determining success of cochlear implantation are broadly related to neural plasticity that appears to be transiently present in deaf individuals. In this article we review the expected outcomes of cochlear implantation, potential predictors of those outcomes, the basic science regarding critical and sensitive periods, and several new research directions in the field of cochlear implantation.

  9. Quality of life and cochlear implantation in Usher syndrome type I.

    NARCIS (Netherlands)

    Damen, G.W.J.A.; Pennings, R.J.E.; Snik, A.F.M.; Mylanus, E.A.M.

    2006-01-01

    OBJECTIVES: The objectives of this descriptive, retrospective study were to evaluate quality of life, hearing, and vision in patients with Usher syndrome type I with and without cochlear implant. METHODS: Quality of life (QoL) of 14 patients with Usher type I (USH1) with a cochlear implant (CI)

  10. Learning and Memory Processes Following Cochlear Implantation:The Missing Piece of the Puzzle

    Directory of Open Access Journals (Sweden)

    David B. Pisoni

    2016-04-01

    Full Text Available At the present time, there is no question that cochlear implants work and often work very well in quiet listening conditions for many profoundly deaf children and adults. The speech and language outcomes data published over the last two decades document quite extensively the clinically significant benefits of cochlear implants. Although there now is a large body of evidence supporting the efficacy of cochlear implants as a medical intervention for profound hearing loss in both children and adults, there still remain a number of challenging unresolved clinical and theoretical issues that deal with the effectiveness of cochlear implants in individual patients that have not yet been successfully resolved. In this paper, we review recent findings on learning and memory, two central topics in the field of cognition that have been seriously neglected in research on cochlear implants. Our research findings on sequence learning, memory and organization processes, and retrieval strategies used in verbal learning and memory of categorized word lists suggests that basic domain-general learning abilities may be the missing piece of the puzzle in terms of understanding the cognitive factors that underlie the enormous individual differences and variability routinely observed in speech and language outcomes following cochlear implantation.

  11. Development of Mandarin spoken language after pediatric cochlear implantation.

    Science.gov (United States)

    Li, Bei; Soli, Sigfrid D; Zheng, Yun; Li, Gang; Meng, Zhaoli

    2014-07-01

    The purpose of this study was to evaluate early spoken language development in young Mandarin-speaking children during the first 24 months after cochlear implantation, as measured by receptive and expressive vocabulary growth rates. Growth rates were compared with those of normally hearing children and with growth rates for English-speaking children with cochlear implants. Receptive and expressive vocabularies were measured with the simplified short form (SSF) version of the Mandarin Communicative Development Inventory (MCDI) in a sample of 112 pediatric implant recipients at baseline, 3, 6, 12, and 24 months after implantation. Implant ages ranged from 1 to 5 years. Scores were expressed in terms of normal equivalent ages, allowing normalized vocabulary growth rates to be determined. Scores for English-speaking children were re-expressed in these terms, allowing direct comparisons of Mandarin and English early spoken language development. Vocabulary growth rates during the first 12 months after implantation were similar to those for normally hearing children less than 16 months of age. Comparisons with growth rates for normally hearing children 16-30 months of age showed that the youngest implant age group (1-2 years) had an average growth rate of 0.68 that of normally hearing children; while the middle implant age group (2-3 years) had an average growth rate of 0.65; and the oldest implant age group (>3 years) had an average growth rate of 0.56, significantly less than the other two rates. Growth rates for English-speaking children with cochlear implants were 0.68 in the youngest group, 0.54 in the middle group, and 0.57 in the oldest group. Growth rates in the middle implant age groups for the two languages differed significantly. The SSF version of the MCDI is suitable for assessment of Mandarin language development during the first 24 months after cochlear implantation. Effects of implant age and duration of implantation can be compared directly across

  12. Across-site patterns of electrically evoked compound action potential amplitude-growth functions in multichannel cochlear implant recipients and the effects of the interphase gap.

    Science.gov (United States)

    Schvartz-Leyzac, Kara C; Pfingst, Bryan E

    2016-11-01

    Electrically evoked compound action potential (ECAP) measures of peak amplitude, and amplitude-growth function (AGF) slope have been shown to reflect characteristics of cochlear health (primarily spiral ganglion density) in anesthetized cochlear-implanted guinea pigs. Likewise, the effect of increasing the interphase gap (IPG) in each of these measures also reflects SGN density in the implanted guinea pig. Based on these findings, we hypothesize that suprathreshold ECAP measures, and also how they change as the IPG is increased, have the potential to be clinically applicable in human subjects. However, further work is first needed in order to determine the characteristics of these measures in humans who use cochlear implants. The current study examined across-site patterns of suprathreshold ECAP measures in 10 bilaterally-implanted, adult cochlear implant users. Results showed that both peak amplitude and slope of the AGF varied significantly from electrode to electrode in ear-specific patterns across the subjects' electrode arrays. As expected, increasing the IPG on average increased the peak amplitude and slope. Across ears, there was a significant, negative correlation between the slope of the ECAP AGF and the duration of hearing loss. Across-site patterns of ECAP peak amplitude and AGF slopes were also compared with common ground impedance values and significant correlations were observed in some cases, depending on the subject and condition. The results of this study, coupled with previous studies in animals, suggest that it is feasible to measure the change in suprathreshold ECAP measures as the IPG increases on most electrodes. Further work is needed to investigate the relationship between these measures and cochlear implant outcomes, and determine how these measures might be used when programming a cochlear-implant processor. Published by Elsevier B.V.

  13. Hearing Preservation Outcomes With a Mid-Scala Electrode in Cochlear Implantation.

    Science.gov (United States)

    Hunter, Jacob B; Gifford, René H; Wanna, George B; Labadie, Robert F; Bennett, Marc L; Haynes, David S; Rivas, Alejandro

    2016-03-01

    To evaluate hearing preservation (HP) outcomes in adult cochlear implant recipients with a mid-scala electrode. Tertiary academic center. Adult patients implanted with a mid-scala electrode between May 2013 and July 2015. Cochlear implantation. Age, sex, surgical approach, residual hearing changes post cochlear implantation, HP rates using different published classifications, and speech perception scores. Fifty ears for 47 patients (mean age, 58.2 yr; range, 23-86) were implanted with the electrode. Recognizing that not all patients were true HP candidates and/or underwent generally accepted HP surgical techniques, 39 ears had preoperative low-frequency hearing (audiometric threshold ≤ 85dB HL at 250Hz), 24 preserved acoustic hearing postoperatively (75.0%). Patients who had preserved acoustic hearing were implanted via round window (N = 18), extended round window (N = 4), or via cochleostomy (N = 2) approaches. Mean threshold elevation for low-frequency pure-tone average (125, 250, and 500  Hz) was 20.2  dB after surgery. 43.8% of patients had aidable low-frequency hearing at activation, 30.0% at 6-months postoperatively, and 30.8% 1-year postopera tively. Using a formula outlined by Skarzynski and colleagues, at 6-months postoperatively, 15.0% of patients had complete HP, whereas 40.0% had partial HP. At 1-year, these percentages decreased to 0% and 38.5%, respectively. Age, type of approach, and perioperative steroid use were not correlated with HP outcomes at activation and 6-months postoperatively (p > 0.05). The mid-scala electrode evaluated allows preservation of low-frequency hearing in patients undergoing cochlear implantation at rates and degrees of preservation close to other reports in the cochlear implant literature.

  14. Standardization of reliability reporting for cochlear implants: an interim report.

    Science.gov (United States)

    Backous, Douglas D; Watson, Stacey D

    2007-04-01

    To propose a standard definition of "out of specification" for cochlear implants and a paradigm for inclusion of category C of the ISO standard 5841-2:2000 for reporting in cumulative survival statistics. A standard definition of "out of specification" and consistent reporting by manufacturers of cochlear implants will create a fair and consistent representation of cumulative survival. This will allow discernment of differences between manufacturers for reliability and for detection of trends in reliability between model types from the same manufacturer. Three separate meetings with representatives of the three manufacturers of cochlear implants marketed in the United States were staged over a 13-mo period. Standard questions, created by the authors, were addressed by each representative to determine the current state of device reliability reporting. Results were presented to clinicians at the William House Cochlear Implant study Group and the Implantable devices sub-committee of the American Academy of Otolaryngology (2004, 2005) and at the 8th International Cochlear Implant Conference (2004) for feedback. After assimilation of feedback by all parties, the standard was written and reviewed by representatives from each manufacturer for accuracy of data. A complaint-driven standard was developed. A "cochlear implant" as an internal device placed and skin closed in surgery. An internal device is "out of specification" when one or more technical characteristics is outside the limits of normal function and results in explantation or non-use by the patient." Children will be reported separately from adults, each model of device will be reported on annually, a minimum of 200 devices must be in each model group for Cumulative Survival Reporting (CSR). Confidence limits are set at 95%. Explants will be determined to be "biological" or "technical." Technical explants are included in CSR reports. Devices failing to meet specifications set by the manufacturer, not in use but

  15. Interaction of tinnitus suppression and hearing ability after cochlear implantation.

    Science.gov (United States)

    Wang, Qian; Li, Jia-Nan; Lei, Guan-Xiong; Chen, Dai-Shi; Wang, Wei-Ze; Chen, Ai-Ting; Mong, Meng-Di; Li, Sun; Jiao, Qing-Shan; Yang, Shi-Ming

    2017-10-01

    To study the postoperative impact of cochlear implants (CIs) on tinnitus, as well as the impact of tinnitus on speech recognition with CI switched on. Fifty-two postlingual deafened CI recipients (21 males and 31 females) were assessed using an established Tinnitus Characteristics Questionnaire and Tinnitus Handicap Inventory (THI) before and after cochlear implantation. The tinnitus loudness was investigated when CI was switched on and off in CI recipients with persistent tinnitus. The relation between tinnitus loudness and recipients' satisfaction of cochlear implantation was analyzed by the visual analogue scale (VAS) score. With CI 'OFF', 42 CI recipients experienced tinnitus postimplant ipsilaterally and 44 contralaterally. Tinnitus was totally suppressed ipsilateral to the CI with CI 'ON' in 42.9%, partially suppressed in 42.9%, unchanged in 11.9% and aggravated in 2.4%. Tinnitus was totally suppressed contralaterally with CI 'ON' in 31.8% of CI recipients, partially suppressed in 47.7%, unchanged in 20.5%. Pearson correlation analysis showed that tinnitus loudness and the results of cochlear implant patients satisfaction was negatively correlated (r = .674, p tinnitus. The tinnitus loudness may affect patients' satisfaction with the use of CI.

  16. Libyan cochlear implant programme: achievements, difficulties, and ...

    African Journals Online (AJOL)

    Data relating to the patients who received cochlear implantation at Tripoli Medical Centre between October 2007 and February 2010 were analysed. Implant operations were performed on 37 patients. All patients received Med-El SONATATI100 devices. Thirty-four (91.9%) of these patients were children, whilst three (8.1%) ...

  17. Improving Access for Pediatric and Adult Cochlear Implant Candidates in Ontario

    Directory of Open Access Journals (Sweden)

    Yvonne Emily James

    2016-10-01

    Full Text Available In 2011, the Ontario Ministry of Health and Long-Term Care announced the one-time allocation of $5.9 million to be shared by cochlear implant programs at five Ontario hospitals. The primary goal of this reform was to address cochlear implant wait times. More specifically, this funding was aimed at reducing adult wait times by 50% and to completely eliminate pediatric waiting lists. Prior to this funding, wait times for pediatric and adult cochlear implants were known to exceed four years. The funding was provided in response to a growing body of research that demonstrates increased speech perception and vocabulary among pediatric recipients, and pressure from parents of children on cochlear implant waiting lists, surgeons and other involved healthcare providers (e.g., auditory verbal therapists, audiologists, and speech language pathologists. The decision to increase funding was also influenced by government stakeholders who believed this one-time investment would be returned as pediatric patients reach adulthood and are better equipped to participate in mainstream (i.e., hearing society. While this one-time funding model has the potential to eliminate wait times for pediatric patients, thereby ensuring these children can access therapeutic services as early as possible, it does not address the future of cochlear implant waiting lists or the capacity of health human resources to absorb this sudden and unprecedented influx of pediatric patients.

  18. Spelling in Written Stories by School-Age Children with Cochlear Implants

    Science.gov (United States)

    Straley, Sara G.; Werfel, Krystal L.; Hendricks, Alison Eisel

    2016-01-01

    This study evaluated the spelling of 3rd to 6th grade children with cochlear implants in written stories. Spelling was analysed using traditional correct/incorrect scoring as well as the Spelling Sensitivity Score, which provides linguistic information about spelling attempts. Children with cochlear implants spelled 86 per cent of words in stories…

  19. Persistent Language Delay Versus Late Language Emergence in Children With Early Cochlear Implantation

    Science.gov (United States)

    Nicholas, Johanna; Tobey, Emily; Davidson, Lisa

    2016-01-01

    Purpose The purpose of the present investigation is to differentiate children using cochlear implants (CIs) who did or did not achieve age-appropriate language scores by midelementary grades and to identify risk factors for persistent language delay following early cochlear implantation. Materials and Method Children receiving unilateral CIs at young ages (12–38 months) were tested longitudinally and classified with normal language emergence (n = 19), late language emergence (n = 22), or persistent language delay (n = 19) on the basis of their test scores at 4.5 and 10.5 years of age. Relative effects of demographic, audiological, linguistic, and academic characteristics on language emergence were determined. Results Age at CI was associated with normal language emergence but did not differentiate late emergence from persistent delay. Children with persistent delay were more likely to use left-ear implants and older speech processor technology. They experienced higher aided thresholds and lower speech perception scores. Persistent delay was foreshadowed by low morphosyntactic and phonological diversity in preschool. Logistic regression analysis predicted normal language emergence with 84% accuracy and persistent language delay with 74% accuracy. Conclusion CI characteristics had a strong effect on persistent versus resolving language delay, suggesting that right-ear (or bilateral) devices, technology upgrades, and improved audibility may positively influence long-term language outcomes. PMID:26501740

  20. Cochlear implant rehabilitation outcomes in Waardenburg syndrome children.

    Science.gov (United States)

    de Sousa Andrade, Susana Margarida; Monteiro, Ana Rita Tomé; Martins, Jorge Humberto Ferreira; Alves, Marisa Costa; Santos Silva, Luis Filipe; Quadros, Jorge Manuel Cardoso; Ribeiro, Carlos Alberto Reis

    2012-09-01

    The purpose of this study was to review the outcomes of children with documented Waardenburg syndrome implanted in the ENT Department of Centro Hospitalar de Coimbra, concerning postoperative speech perception and production, in comparison to the rest of non-syndromic implanted children. A retrospective chart review was performed for children congenitally deaf who had undergone cochlear implantation with multichannel implants, diagnosed as having Waardenburg syndrome, between 1992 and 2011. Postoperative performance outcomes were assessed and confronted with results obtained by children with non-syndromic congenital deafness also implanted in our department. Open-set auditory perception skills were evaluated by using European Portuguese speech discrimination tests (vowels test, monosyllabic word test, number word test and words in sentence test). Meaningful auditory integration scales (MAIS) and categories of auditory performance (CAP) were also measured. Speech production was further assessed and included results on meaningful use of speech Scale (MUSS) and speech intelligibility rating (SIR). To date, 6 implanted children were clinically identified as having WS type I, and one met the diagnosis of type II. All WS children received multichannel cochlear implants, with a mean age at implantation of 30.6±9.7months (ranging from 19 to 42months). Postoperative outcomes in WS children were similar to other nonsyndromic children. In addition, in number word and vowels discrimination test WS group showed slightly better performances, as well as in MUSS and MAIS assessment. Our study has shown that cochlear implantation should be considered a rehabilitative option for Waardenburg syndrome children with profound deafness, enabling the development and improvement of speech perception and production abilities in this group of patients, reinforcing their candidacy for this audio-oral rehabilitation method. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  1. Direct measurement of cerebrospinal fluid pressure through the cochlea in a congenitally deaf child with Mondini dysplasia undergoing cochlear implantation.

    Science.gov (United States)

    Graham, J M; Ashcroft, P

    1999-03-01

    Perilymph/cerebrospinal fluid (CSF) "gushers" may occur at cochleostomy during cochlear implant surgery, particularly in patients with congenital cochlear duct malformation in which CSF in the internal auditory meatus is in direct communication with the perilymphatic space in the cochlea. The object of the study was to measure the pressure and flow of a CSF gusher at cochleostomy. The design was a preoperative pressure measurement. The setting was a multidisciplinary cochlear implant program. A 4-year-old girl with bilateral Mondini deformity undergoing cochlear implantation was studied. A size 23 FG intravenous cannula was inserted into the cochlea and connected to a pediatric drip set to form an improvised manometer. Intracochlear fluid pressure was measured at 14 cm H2O, equivalent to the normal CSF pressure that would be recorded in a child of this age at lumbar puncture. An indirect measurement of the likely size of the CSF/perilymph defect was made. This technique may allow better assessment of the risk of postoperative CSF leakage and meningitis. This simple technique of measuring the pressure in a perilymph gusher can be used to assess the need for careful sealing of the cochleostomy, to measure the reduction in pressure produced by head elevation or a spinal drain, and to assess the probable size of a defect in the lamina cribrosa.

  2. [Cochlear implant in patients with congenital malformation of inner ear].

    Science.gov (United States)

    Han, Dong-yi; Wu, Wen-ming; Xi, Xin; Huang, De-liang; Yang, Wei-yan

    2004-02-01

    To study surgical difficulty and key of the cochlear implant in patients with congenital malformation of inner ear. The cochlear implantations were performed in our department from Jan. 2001 to Apr. 2003 for 18 patients with the malformation of inner ear. In this series, there were 11 cases of large vestibular aqueduct syndrome (LVAS), 3 cases of Waardenberg syndrome, 3 cases of Mondini malformation, and 1 case of Usher syndrome. All 18 patients accepted the Nucleus 24-channel cochlear implantations, including Nucleus straight electrode in 13 cases but Contour implantation in 5 cases of LVAS. During operations, leakage of perilymph but not cerebrospinal fluid (CSF) from the open of scala tympani occurred in 11 cases of LVAS, however, the electrode was inserted successfully. The abnormalities of round window occurred in one of 3 cases of Waardenberg syndrome and 3 cases of Mondini malformation, respectively. The cochlear implant could be conducted successfully for the LVAS, and the postoperative effect was same as the ones for the deafness persons with normal development of inner ear. However, for the patients with Mondini syndrome and common cavity, it is important to accurately assess the extent of abnormalities in the inner ear and accompanied malformation before operation, and to evaluate the full extent of difficulties of the operation in order to minimize the risk of CSF leakage and meningitis.

  3. The scala vestibuli for cochlear implantation. An anatomic study.

    Science.gov (United States)

    Gulya, A J; Steenerson, R L

    1996-02-01

    Traditionally, cochlear implantation has used the scala tympani (ST) for electrode insertion. When faced with ST ossification, the surgeon may elect to drill out the cochlea to accomplish partial electrode insertion. Theoretically, another option in this situation is to insert the electrode into the scala vestibuli (SV). To determine whether or not the dimensions of the SV are sufficient to accommodate an electrode array so as to assess the feasibility of SV cochlear implantation. The study of 20 normal human temporal bones, comparing the maximum diameter and surface area of the ST with those of the combined SV and scala media. The dimensions of the SV and scala media were comparable to those of the ST and appeared sufficient to accommodate a cochlear implant electrode array. It appears that the combination of SV and scala media is a viable alternative route for electrode insertion, at least on the basis of anatomic dimensions, in those cases in which the ST is obliterated.

  4. Cochlear Implant

    Directory of Open Access Journals (Sweden)

    Mehrnaz Karimi

    1992-04-01

    Full Text Available People with profound hearing loss are not able to use some kinds of conventional amplifiers due to the nature of their loss . In these people, hearing sense is stimulated only when the auditory nerve is activated via electrical stimulation. This stimulation is possible through cochlear implant. In fact, for the deaf people who have good mental health and can not use surgical and medical treatment and also can not benefit from air and bone conduction hearing aids, this device is used if they have normal central auditory system. The basic parts of the device included: Microphone, speech processor, transmitter, stimulator and receiver, and electrode array.

  5. Simultaneous Communication and Cochlear Implants in the Classroom?

    NARCIS (Netherlands)

    Blom, H.C.; Marschark, M.

    2015-01-01

    This study was designed to evaluate the potential of simultaneous communication (sign and speech together) to support classroom learning by college students who use cochlear implants (CIs). Metacognitive awareness of learning also was evaluated. A within-subjects design involving 40 implant users

  6. Mitochondrial Sensorineural Hearing Loss: A Retrospective Study and a Description of Cochlear Implantation in a MELAS Patient

    Directory of Open Access Journals (Sweden)

    Mauro Scarpelli

    2012-01-01

    Full Text Available Hearing impairment is common in patients with mitochondrial disorders, affecting over half of all cases at some time in the course of the disease. In some patients, deafness is only part of a multisystem disorder. By contrast, there are also a number of “pure” mitochondrial deafness disorders, the most common probably being maternally inherited. We retrospectively analyzed the last 60 genetically confirmed mitochondrial disorders diagnosed in our Department: 28 had bilateral sensorineural hearing loss, whereas 32 didn't present ear's abnormalities, without difference about sex and age of onset between each single group of diseases. We reported also a case of MELAS patient with sensorineural hearing loss, in which cochlear implantation greatly contributed to the patient's quality of life. Our study suggests that sensorineural hearing loss is an important feature in mitochondrial disorders and indicated that cochlear implantation can be recommended for patients with MELAS syndrome and others mitochondrial disorders.

  7. Cyborgization: Deaf Education for Young Children in the Cochlear Implantation Era

    Science.gov (United States)

    Valente, Joseph Michael

    2011-01-01

    The author, who was raised oral deaf himself, recounts a visit to a school for young deaf children and discovers that young d/Deaf children and their rights are subverted by the cochlear implantation empire. The hypercapitalist, techno-manic times of cochlear implantation has wreaked havoc to the lives of not only young children with deafness but…

  8. Evidence of across-channel processing for spectral-ripple discrimination in cochlear implant listeners a

    Science.gov (United States)

    Ho Won, Jong; Jones, Gary L.; Drennan, Ward R.; Jameyson, Elyse M.; Rubinstein, Jay T.

    2011-01-01

    Spectral-ripple discrimination has been used widely for psychoacoustical studies in normal-hearing, hearing-impaired, and cochlear implant listeners. The present study investigated the perceptual mechanism for spectral-ripple discrimination in cochlear implant listeners. The main goal of this study was to determine whether cochlear implant listeners use a local intensity cue or global spectral shape for spectral-ripple discrimination. The effect of electrode separation on spectral-ripple discrimination was also evaluated. Results showed that it is highly unlikely that cochlear implant listeners depend on a local intensity cue for spectral-ripple discrimination. A phenomenological model of spectral-ripple discrimination, as an “ideal observer,” showed that a perceptual mechanism based on discrimination of a single intensity difference cannot account for performance of cochlear implant listeners. Spectral modulation depth and electrode separation were found to significantly affect spectral-ripple discrimination. The evidence supports the hypothesis that spectral-ripple discrimination involves integrating information from multiple channels. PMID:21973363

  9. Advancing Binaural Cochlear Implant Technology

    Directory of Open Access Journals (Sweden)

    Mathias Dietz

    2015-12-01

    Full Text Available This special issue contains a collection of 13 papers highlighting the collaborative research and engineering project entitled Advancing Binaural Cochlear Implant Technology—ABCIT—as well as research spin-offs from the project. In this introductory editorial, a brief history of the project is provided, alongside an overview of the studies.

  10. Listening Effort With Cochlear Implant Simulations

    NARCIS (Netherlands)

    Pals, Carina; Sarampalis, Anastasios; Başkent, Deniz

    2013-01-01

    Purpose: Fitting a cochlear implant (CI) for optimal speech perception does not necessarily optimize listening effort. This study aimed to show that listening effort may change between CI processing conditions for which speech intelligibility remains constant. Method: Nineteen normal-hearing

  11. "COCHLEAR IMPLANTATION IN PATIENTS WITH INNER EAR MALFORMATIONS"

    Directory of Open Access Journals (Sweden)

    P. Borghei S. Abdi

    2004-08-01

    Full Text Available Performing cochlear implantation in patients with inner ear malformation has always been a matter of dispute. This study was designed to analyze the operative findings,complications, and postoperative performance of patients with inner ear anomalies who underwent cochlear implantation. Six patients with inner ear malformations underwent implantation in our academic tertiary referral center from 1997 to 2002. The average follow-up period was 27 months. Malformations included one incomplete partition, one common cavity, one narrow internal acoustic canal (IAC in a patient with Riley-Day syndrome and 3 cases of large vestibular aqueduct. All received multi-channel implants either Nucleus 22 or Clarion device. Facial nerve was anomalous in 2 cases. CSF gusher occurred in 4 patients, which was controlled with packing the cochleostomy site. In all cases, the full length of electrode array was inserted, except one with Mondini's dysplasia where insertion failed in the first operation and was referred to another center for a successful surgery on the opposite ear. No other surgical complications were encountered. In 4 cases, all the 22 electrodes could be activated. All patients showed improved hearing performance after implantation. Four showed open-set speech recognition. The one with narrow IAC showed improved awareness to environmental sounds. In the other case (common cavity, the perception tests could not be performed because of very young age. Cochlear implantation in patients with inner ear malformations is a successful way of rehabilitation, although complications should be expected and auditory responses may be highly variable and relatively moderate.

  12. The contribution of short-term memory capacity to reading ability in adolescents with cochlear implants.

    Science.gov (United States)

    Edwards, Lindsey; Aitkenhead, Lynne; Langdon, Dawn

    2016-11-01

    This study aimed to establish the relationship between short-term memory capacity and reading skills in adolescents with cochlear implants. A between-groups design compared a group of young people with cochlear implants with a group of hearing peers on measures of reading, and auditory and visual short-term memory capacity. The groups were matched for non-verbal IQ and age. The adolescents with cochlear implants were recruited from the Cochlear Implant Programme at a specialist children's hospital. The hearing participants were recruited from the same schools as those attended by the implanted adolescents. Participants were 18 cochlear implant users and 14 hearing controls, aged between 12 and 18 years. All used English as their main language and had no significant learning disability or neuro-developmental disorder. Short-term memory capacity was assessed in the auditory modality using Forward and Reverse Digit Span from the WISC IV UK, and visually using Forward and Reverse Memory from the Leiter-R. Individual word reading, reading comprehension and pseudoword decoding were assessed using the WIAT II UK. A series of ANOVAs revealed that the adolescents with cochlear implants had significantly poorer auditory short-term memory capacity and reading skills (on all measures) compared with their hearing peers. However, when Forward Digit Span was entered into the analyses as a covariate, none of the differences remained statistically significant. Deficits in immediate auditory memory persist into adolescence in deaf children with cochlear implants. Short-term auditory memory capacity is an important neurocognitive process in the development of reading skills after cochlear implantation in childhood that remains evident in later adolescence. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  13. Speech and language development in cognitively delayed children with cochlear implants.

    Science.gov (United States)

    Holt, Rachael Frush; Kirk, Karen Iler

    2005-04-01

    The primary goals of this investigation were to examine the speech and language development of deaf children with cochlear implants and mild cognitive delay and to compare their gains with those of children with cochlear implants who do not have this additional impairment. We retrospectively examined the speech and language development of 69 children with pre-lingual deafness. The experimental group consisted of 19 children with cognitive delays and no other disabilities (mean age at implantation = 38 months). The control group consisted of 50 children who did not have cognitive delays or any other identified disability. The control group was stratified by primary communication mode: half used total communication (mean age at implantation = 32 months) and the other half used oral communication (mean age at implantation = 26 months). Children were tested on a variety of standard speech and language measures and one test of auditory skill development at 6-month intervals. The results from each test were collapsed from blocks of two consecutive 6-month intervals to calculate group mean scores before implantation and at 1-year intervals after implantation. The children with cognitive delays and those without such delays demonstrated significant improvement in their speech and language skills over time on every test administered. Children with cognitive delays had significantly lower scores than typically developing children on two of the three measures of receptive and expressive language and had significantly slower rates of auditory-only sentence recognition development. Finally, there were no significant group differences in auditory skill development based on parental reports or in auditory-only or multimodal word recognition. The results suggest that deaf children with mild cognitive impairments benefit from cochlear implantation. Specifically, improvements are evident in their ability to perceive speech and in their reception and use of language. However, it may

  14. Assessment of morphological-functional state of children with cochlear implants

    Directory of Open Access Journals (Sweden)

    V.M. Pysanko

    2016-10-01

    Full Text Available Purpose: assessment of morphological-functional state of pre-school age children with cochlear implants and substantiation of need in post-operative rehabilitation in period of preparation for comprehensive school. Material: we tested weakly hearing children with cochlear implants (n=127, age - 5.6±0.6 years. They were the main group. Control group consisted of children with normal hearing (n=70, age - 5.7±0.4 years. Morphological-functional state was assessed by indicators of physical and biological condition, visual analyzer, posture parameters and foot arch, muscular system and level of coordination. We calculated index of integral morphological-functional state assessment. Results: Morphological functional state of most of children (with cochlear implants was characterized by low physical condition indicators and disharmony. We observed delay in biological development. Index of morphological-functional state integral assessment witnesses, that such child can not study in comprehensive school. Rehabilitation program can reduce the gap between children with normal hearing and those with cochlear implants. Conclusions: Rehabilitation program facilitates quicker domestic and social rehabilitation of children at the account of widening the circle of communication, learning new actions and conceptions. It can permit for such children to study at school together with their healthy peers.

  15. Cochlear Implantation and Single-sided Deafness: A Systematic Review of the Literature

    Directory of Open Access Journals (Sweden)

    Cabral Junior, Francisco

    2015-07-01

    Full Text Available Introduction Current data show that binaural hearing is superior to unilateral hearing, specifically in the understanding of speech in noisy environments. Furthermore, unilateral hearing reduce onés ability to localize sound. Objectives This study provides a systematic review of recent studies to evaluate the outcomes of cochlear implantation in patients with single-sided deafness (SSD with regards to speech discrimination, sound localization and tinnitus suppression. Data Synthesis We performed a search in the PubMed, Cochrane Library and Lilacs databases to assess studies related to cochlear implantation in patients with unilateral deafness. After critical appraisal, eleven studies were selected for data extraction and analysis of demographic, study design and outcome data. Conclusion Although some studies have shown encouraging results on cochlear implantation and SSD, all fail to provide a high level of evidence. Larger studies are necessary to define the tangible benefits of cochlear implantation in patients with SSD.

  16. A phone-assistive device based on Bluetooth technology for cochlear implant users.

    Science.gov (United States)

    Qian, Haifeng; Loizou, Philipos C; Dorman, Michael F

    2003-09-01

    Hearing-impaired people, and particularly hearing-aid and cochlear-implant users, often have difficulty communicating over the telephone. The intelligibility of telephone speech is considerably lower than the intelligibility of face-to-face speech. This is partly because of lack of visual cues, limited telephone bandwidth, and background noise. In addition, cellphones may cause interference with the hearing aid or cochlear implant. To address these problems that hearing-impaired people experience with telephones, this paper proposes a wireless phone adapter that can be used to route the audio signal directly to the hearing aid or cochlear implant processor. This adapter is based on Bluetooth technology. The favorable features of this new wireless technology make the adapter superior to traditional assistive listening devices. A hardware prototype was built and software programs were written to implement the headset profile in the Bluetooth specification. Three cochlear implant users were tested with the proposed phone-adapter and reported good speech quality.

  17. Paediatric Cochlear Implantation in Patients with Waardenburg Syndrome.

    Science.gov (United States)

    van Nierop, Josephine W I; Snabel, Rebecca R; Langereis, Margreet; Pennings, Ronald J E; Admiraal, Ronald J C; Mylanus, Emmanuel A M; Kunst, Henricus P M

    2016-01-01

    To analyse the benefit of cochlear implantation in young deaf children with Waardenburg syndrome (WS) compared to a reference group of young deaf children without additional disabilities. A retrospective study was conducted on children with WS who underwent cochlear implantation at the age of 2 years or younger. The post-operative results for speech perception (phonetically balanced standard Dutch consonant-vocal-consonant word lists) and language comprehension (the Reynell Developmental Language Scales, RDLS), expressed as a language quotient (LQ), were compared between the WS group and the reference group by using multiple linear regression analysis. A total of 14 children were diagnosed with WS, and 6 of them had additional disabilities. The WS children were implanted at a mean age of 1.6 years and the 48 children of the reference group at a mean age of 1.3 years. The WS children had a mean phoneme score of 80% and a mean LQ of 0.74 at 3 years post-implantation, and these results were comparable to those of the reference group. Only the factor additional disabilities had a significant negative influence on auditory perception and language comprehension. Children with WS performed similarly to the reference group in the present study, and these outcomes are in line with the previous literature. Although good counselling about additional disabilities concomitant to the syndrome is relevant, cochlear implantation is a good rehabilitation method for children with WS. © 2016 S. Karger AG, Basel.

  18. Recognition of "real-world" musical excerpts by cochlear implant recipients and normal-hearing adults.

    Science.gov (United States)

    Gfeller, Kate; Olszewski, Carol; Rychener, Marly; Sena, Kimberly; Knutson, John F; Witt, Shelley; Macpherson, Beth

    2005-06-01

    The purposes of this study were (a) to compare recognition of "real-world" music excerpts by postlingually deafened adults using cochlear implants and normal-hearing adults; (b) to compare the performance of cochlear implant recipients using different devices and processing strategies; and (c) to examine the variability among implant recipients in recognition of musical selections in relation to performance on speech perception tests, performance on cognitive tests, and demographic variables. Seventy-nine cochlear implant users and 30 normal-hearing adults were tested on open-set recognition of systematically selected excerpts from musical recordings heard in real life. The recognition accuracy of the two groups was compared for three musical genre: classical, country, and pop. Recognition accuracy was correlated with speech recognition scores, cognitive measures, and demographic measures, including musical background. Cochlear implant recipients were significantly less accurate in recognition of previously familiar (known before hearing loss) musical excerpts than normal-hearing adults (p genre. Implant recipients were most accurate in the recognition of country items and least accurate in the recognition of classical items. There were no significant differences among implant recipients due to implant type (Nucleus, Clarion, or Ineraid), or programming strategy (SPEAK, CIS, or ACE). For cochlear implant recipients, correlations between melody recognition and other measures were moderate to weak in strength; those with statistically significant correlations included age at time of testing (negatively correlated), performance on selected speech perception tests, and the amount of focused music listening following implantation. Current-day cochlear implants are not effective in transmitting several key structural features (i.e., pitch, harmony, timbral blends) of music essential to open-set recognition of well-known musical selections. Consequently, implant

  19. Working memory, short-term memory and reading proficiency in school-age children with cochlear implants.

    Science.gov (United States)

    Bharadwaj, Sneha V; Maricle, Denise; Green, Laura; Allman, Tamby

    2015-10-01

    The objective of the study was to examine short-term memory and working memory through both visual and auditory tasks in school-age children with cochlear implants. The relationship between the performance on these cognitive skills and reading as well as language outcomes were examined in these children. Ten children between the ages of 7 and 11 years with early-onset bilateral severe-profound hearing loss participated in the study. Auditory and visual short-term memory, auditory and visual working memory subtests and verbal knowledge measures were assessed using the Woodcock Johnson III Tests of Cognitive Abilities, the Wechsler Intelligence Scale for Children-IV Integrated and the Kaufman Assessment Battery for Children II. Reading outcomes were assessed using the Woodcock Reading Mastery Test III. Performance on visual short-term memory and visual working memory measures in children with cochlear implants was within the average range when compared to the normative mean. However, auditory short-term memory and auditory working memory measures were below average when compared to the normative mean. Performance was also below average on all verbal knowledge measures. Regarding reading outcomes, children with cochlear implants scored below average for listening and passage comprehension tasks and these measures were positively correlated to visual short-term memory, visual working memory and auditory short-term memory. Performance on auditory working memory subtests was not related to reading or language outcomes. The children with cochlear implants in this study demonstrated better performance in visual (spatial) working memory and short-term memory skills than in auditory working memory and auditory short-term memory skills. Significant positive relationships were found between visual working memory and reading outcomes. The results of the study provide support for the idea that WM capacity is modality specific in children with hearing loss. Based on these

  20. Assessment of auditory cortical function in cochlear implant patients using 15O PET

    International Nuclear Information System (INIS)

    Young, J.P.; O'Sullivan, B.T.; Gibson, W.P.; Sefton, A.E.; Mitchell, T.E.; Sanli, H.; Cervantes, R.; Withall, A.; Royal Prince Alfred Hospital, Sydney,

    1998-01-01

    Full text: Cochlear implantation has been an extraordinarily successful method of restoring hearing and the potential for full language development in pre-lingually and post-lingually deaf individuals (Gibson 1996). Post-lingually deaf patients, who develop their hearing loss later in life, respond best to cochlear implantation within the first few years of their deafness, but are less responsive to implantation after several years of deafness (Gibson 1996). In pre-lingually deaf children, cochlear implantation is most effect in allowing the full development language skills when performed within a critical period, in the first 8 years of life. These clinical observations suggest considerable neural plasticity of the human auditory cortex in acquiring and retaining language skills (Gibson 1996, Buchwald 1990). Currently, electrocochleography is used to determine the integrity of the auditory pathways to the auditory cortex. However, the functional integrity of the auditory cortex cannot be determined by this method. We have defined the extent of activation of the auditory cortex and auditory association cortex in 6 normal controls and 6 cochlear implant patients using 15 O PET functional brain imaging methods. Preliminary results have indicated the potential clinical utility of 15 O PET cortical mapping in the pre-surgical assessment and post-surgical follow up of cochlear implant patients. Copyright (1998) Australian Neuroscience Society

  1. [Applied anatomy of scala tympani inlet related to cochlear implantation].

    Science.gov (United States)

    Zou, Tuanming; Guo, Menghe; Zhang, Hongzheng; Shu, Fan; Xie, Nanping

    2012-06-01

    To investigate the related parameters of the temporal bone structure for determining the position of implanting electrode into the scala tympani in cochlear implantation surgery through the facial recess and epitympanum approach. In a surgical simulation experiment, 20 human temporal bones were studied and measured to determine the related parameters of the temporal bone structure. The distance 5.91∓0.29 mm between the short process of the incus and the round window niche, 2.11∓0.18 mm between the stapes and the round window niche, 6.70∓0.19 mm between the facial nerve in the perpendicular paragraph and the round window niche, 2.22∓0.21 mm from the pyramidal eminence to the round window, and 2.16∓0.14 mm between the stapes and the round window. The minimal distance between the implanting electrode and the vestibular window was 2.12∓0.19 mm. The distance between the cochleariform process and the round window niche was 3.79∓0.17 mm. The position of the cochlear electrode array insertion into the second cochlear turn was 2.25∓0.13 mm under the stapes. The location of the cochlear electrode array insertion into the second cochlear turn was 2.28∓0.20 mm inferior to the pyramidal eminence. These parameters provide a reference value to determine the different positions of cochlear electrode array insertion into the scale tympani in different patients.

  2. Pre-, intra- and post-operative imaging of cochlear implants

    Energy Technology Data Exchange (ETDEWEB)

    Vogl, T.J.; Naguib, N.N.N.; Burck, I. [University Hospital Frankfurt (Germany). Inst. of Diagnostic and Interventional Radiology; Tawfik, A. [Mansoura Univ. (Egypt). Dept. of Diagnostic and Interventional Radiology; Emam, A. [University Hospital Alexandria (Egypt). Dept. of Diagnostic and Interventional Radiology; Nour-Eldin, A. [University Hospital Cairo (Egypt). Dept. of Radiology; Stoever, T. [University Hospital of Frankfurt (Germany). Dept. of Otolaryngology

    2015-11-15

    The purpose of this review is to present essential imaging aspects in patients who are candidates for a possible cochlear implant as well as in postsurgical follow-up. Imaging plays a major role in providing information on preinterventional topography, variations and possible infections. Preoperative imaging using DVT, CT, MRI or CT and MRI together is essential for candidate selection, planning of surgical approach and exclusion of contraindications like the complete absence of the cochlea or cochlear nerve, or infection. Relative contraindications are variations of the cochlea and vestibulum. Intraoperative imaging can be performed by fluoroscopy, mobile radiography or DVT. Postoperative imaging is regularly performed by conventional X-ray, DVT, or CT. In summary, radiological imaging has its essential role in the pre- and post-interventional period for patients who are candidates for cochlear implants.

  3. Cone-beam computed tomography in children with cochlear implants: The effect of electrode array position on ECAP.

    Science.gov (United States)

    Lathuillière, Marine; Merklen, Fanny; Piron, Jean-Pierre; Sicard, Marielle; Villemus, Françoise; Menjot de Champfleur, Nicolas; Venail, Frédéric; Uziel, Alain; Mondain, Michel

    2017-01-01

    To assess the feasibility of using cone-beam computed tomography (CBCT) in young children with cochlear implants (CIs) and study the effect of intracochlear position on electrophysiological and behavioral measurements. A total of 40 children with either unilateral or bilateral cochlear implants were prospectively included in the study. Electrode placement and insertion angles were studied in 55 Cochlear ® implants (16 straight arrays and 39 perimodiolar arrays), using either CBCT or X-ray imaging. CBCT or X-ray imaging were scheduled when the children were leaving the recovery room. We recorded intraoperative and postoperative neural response telemetry threshold (T-NRT) values, intraoperative and postoperative electrode impedance values, as well as behavioral T (threshold) and C (comfort) levels on electrodes 1, 5, 10, 15 and 20. CBCT imaging was feasible without any sedation in 24 children (60%). Accidental scala vestibuli insertion was observed in 3 out of 24 implants as assessed by CBCT. The mean insertion angle was 339.7°±35.8°. The use of a perimodiolar array led to higher angles of insertion, lower postoperative T-NRT, as well as decreased behavioral T and C levels. We found no significant effect of either electrode array position or angle of insertion on electrophysiological data. CBCT appears to be a reliable tool for anatomical assessment of young children with CIs. Intracochlear position had no significant effect on the electrically evoked compound action potential (ECAP) threshold. Our CBCT protocol must be improved to increase the rate of successful investigations. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  4. Infectious complications of pediatric cochlear implants are highly influenced by otitis media.

    Science.gov (United States)

    Vila, Peter M; Ghogomu, Nsangou T; Odom-John, Audrey R; Hullar, Timothy E; Hirose, Keiko

    2017-06-01

    Determine the incidence of ear infections in cochlear implant patients, evaluate the contribution of otitis media to complications, describe the bacteriology of otitis media in the cochlear implant population, the treatment provided at our center, and the long term outcome. Data collected included age at implantation, history of otitis media or ear tubes, etiology of hearing loss, inner ear anatomy, postoperative infections, time to infection, route of antibiotic administration, and interventions for infections. Categories of infection were acute otitis media, otitis media with effusion, tube otorrhea, meningitis, scalp cellulitis, and infection at the implant site. Middle ear infections were diagnosed in 37% of implanted ears. Extension of middle ear infections into the implant site occurred in 2.8% of all implants (n = 16). Of the 16 infected devices, 10 were successfully treated with antibiotic therapy and did not require explantation. The retained implant group and explanted group both included some middle ear microbes such as Haemophilus influenzae and Streptococcus pneumoniae, as well as skin flora such as Staphylococcus aureus. Otitis media in pediatric cochlear implant patients is a common event and usually does not lead to complications of the cochlear implant. However, when the ear infection spreads to the scalp and the implant site, it is still possible to eliminate the infection using antibiotic therapy, particularly when treatment is directed to the specific organism that is recovered from the infected space and the duration and route of antibiotic treatment is carefully considered. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Cochlear implantation in children with Jervell and Lange-Nielsen syndrome - a cautionary tale.

    Science.gov (United States)

    Broomfield, Stephen J; Bruce, Iain A; Henderson, Lise; Ramsden, Richard T; Green, Kevin M J

    2012-08-01

    Jervell and Lange-Nielsen (JLN) syndrome is a rare cause of congenital profound hearing loss associated with a prolonged QT interval on the electrocardiogram. Children presenting for cochlear implantation with this condition may be asymptomatic but are at risk of sudden death. SCREENING AND SUBSEQUENT: careful management is therefore required to ensure a successful outcome. We present our experience of cochlear implantation in children with JLN syndrome, including two who died unexpectedly, and suggest a protocol for management of such cases. Clinical presentation Four cases of cochlear implantation in JLN syndrome are described. None had any previous cardiological family history. Two were diagnosed pre-operatively but, despite appropriate management under a cardiologist, died from cardiac arrest; the first in the perioperative period following reimplantation for infection, and the second unrelated to his cochlear implant surgery. The other two patients were diagnosed only subsequent to their implantation and continue to use their implants successfully. These cases highlight the variation in presentation of JLN syndrome, and the spectrum of disease severity that exists. Our protocol stresses the importance of careful assessment and counselling of parents by an experienced implant team.

  6. A case report: the first successful cochlear implant in Uganda.

    African Journals Online (AJOL)

    A case report: the first successful cochlear implant in Uganda. Richard Byaruhanga1, J. ... The patient was a 23 year old male whose presenting com- plaint was inability to .... Custom Sound by Cochlear (the company that manu- factures the ...

  7. Ethical considerations in resource allocation in a cochlear implant program.

    Science.gov (United States)

    Westerberg, Brian D; Pijl, Sipke; McDonald, Michael

    2008-04-01

    To review processes of resource allocation and the ethical considerations relevant to the fair allocation of a limited number of cochlear implants to increasing numbers of potential recipients. Review of relevant considerations. Tertiary referral hospital. Editorial discussion of the ethical issues of resource allocation. Heterogeneity of audiometric thresholds, self-reported disability of hearing loss, age of the potential cochlear implant recipient, cost-effectiveness, access to resources, compliance with follow-up, social support available to the recipient, social consequences of hearing impairment, and other recipient-related factors. In a publicly funded health care system, there will always be a need for decision-making processes for allocation of finite fiscal resources. All candidates for cochlear implantation deserve fair consideration. However, they are a heterogeneous group in terms of needs and expected outcomes consisting of traditional and marginal candidates, with a wide range of benefit from acoustic amplification. We argue that implant programs should thoughtfully prioritize treatment on the basis of need and potential benefit. We reject queuing on the basis of "first-come, first-served" or on the basis of perceived social worth.

  8. Factors contributing to communication skills development in cochlear implanted children.

    Science.gov (United States)

    Ostojić, Sanja; Djoković, Sanja; Radić-šestić, Marina; Nikolić, Mina; Mikić, Branka; Mirić, Danica

    2015-08-01

    Over the last 10 years more than 300 persons received cochlear implant in Serbia and more than 90% of the recipients were children under 10 years of age. The program of cochlear implantation includes postoperative rehabilitation in which cognitive, integrative and developmental methods are used. The study was conducted to reveal factors affecting communication performance (CP) of cochlear implanted (Cl) children. Special attention was focused on the influence of the duration and intensity of rehabilitation and hearing age on further development of communication skills. A group of 30 CI children (13 boys and 17 girls) aged 2 to 5 years was enrolled in the study. All of the children had average intelligence and no other developmental disorder. They lived in families and attended rehabilitative seances 3 to 5 times a week. Their parents/caregivers answered structured questionnaire about functioning after pediatric cochlear implantation (FAPCI) and the results were the subject of detailed statistical analysis. Analysis of variance did not show any difference between the boys and the girls regarding FAPCI achievements (F(1, 28) = 2.909; p = 0.099) and age aberration in CP score (F(1,28) = 0.114, p = 0.738). Correlation analysis showed a statistically significant difference in FAPCI scores related to hearing age and duration of rehabilitation. Regression analysis (enter method) showed that model consisting of indipendent variables significantly contributed to prediction of overall FAPCI scores and Adjusted R2 value could explain 32% difference in communication skills of participants in this study. Communication skills of CI children evaluated by FAPCI are falling behind normatives for normal hearing children 18.6 months on the average. Hearing age, duration and intensity of rehabilitation have positive predictive value for communication skills development. Later identification of hearing loss and later cochlear implantation lead to delayed development of communication

  9. Cochlear Implant Outcomes and Genetic Mutations in Children with Ear and Brain Anomalies

    Directory of Open Access Journals (Sweden)

    Micol Busi

    2015-01-01

    Full Text Available Background. Specific clinical conditions could compromise cochlear implantation outcomes and drastically reduce the chance of an acceptable development of perceptual and linguistic capabilities. These conditions should certainly include the presence of inner ear malformations or brain abnormalities. The aims of this work were to study the diagnostic value of high resolution computed tomography (HRCT and magnetic resonance imaging (MRI in children with sensorineural hearing loss who were candidates for cochlear implants and to analyse the anatomic abnormalities of the ear and brain in patients who underwent cochlear implantation. We also analysed the effects of ear malformations and brain anomalies on the CI outcomes, speculating on their potential role in the management of language developmental disorders. Methods. The present study is a retrospective observational review of cochlear implant outcomes among hearing-impaired children who presented ear and/or brain anomalies at neuroimaging investigations with MRI and HRCT. Furthermore, genetic results from molecular genetic investigations (GJB2/GJB6 and, additionally, in selected cases, SLC26A4 or mitochondrial-DNA mutations on this study group were herein described. Longitudinal and cross-sectional analysis was conducted using statistical tests. Results. Between January 1, 1996 and April 1, 2012, at the ENT-Audiology Department of the University Hospital of Ferrara, 620 cochlear implantations were performed. There were 426 implanted children at the time of the present study (who were <18 years. Among these, 143 patients (64 females and 79 males presented ear and/or brain anomalies/lesions/malformations at neuroimaging investigations with MRI and HRCT. The age of the main study group (143 implanted children ranged from 9 months and 16 years (average = 4.4; median = 3.0. Conclusions. Good outcomes with cochlear implants are possible in patients who present with inner ear or brain abnormalities

  10. The influence of cochlear implant electrode position on performance

    NARCIS (Netherlands)

    Marel, K.S. van der; Briaire, J.J.; Verbist, B.M.; Muurling, T.J.; Frijns, J.H.M.

    2015-01-01

    To study the relation between variables related to cochlear implant electrode position and speech perception performance scores in a large patient population.The study sample consisted of 203 patients implanted with a CII or HiRes90K implant with a HiFocus 1 or 1J electrode of Advanced Bionics.

  11. Hearing experience and receptive vocabulary development in deaf children with cochlear implants.

    Science.gov (United States)

    Fagan, Mary K; Pisoni, David B

    2010-01-01

    This study investigated receptive vocabulary delay in deaf children with cochlear implants. Participants were 23 children with profound hearing loss, ages 6-14 years, who received a cochlear implant between ages 1.4 and 6 years. Duration of cochlear implant use ranged from 3.7 to 11.8 years. Peabody Picture Vocabulary Test, Third Edition (PPVT-III) data were analyzed first by examining children's errors for evidence of difficulty in specific lexical content areas, and second by calculating standard scores with reference to hearing age (HA) (i.e., chronological age [CA]--age at implantation) rather than CA. Participants showed evidence of vocabulary understanding across all PPVT-III content categories with no strong evidence of disproportionate numbers of errors in any specific content area despite below-average mean standard scores. However, whereas mean standard scores were below the test mean established for hearing children when based on CA, they were within the average range for hearing children when calculated based on HA. Thus, children's vocabulary knowledge was commensurate with years of cochlear implant experience, providing support for the role of spoken language experience in vocabulary acquisition.

  12. Phonological working memory and its relationship with language abilities in children with cochlear implants

    Directory of Open Access Journals (Sweden)

    Fatemeh Haresabadi

    2014-12-01

    Full Text Available Background and Aim: Many studies have demonstrated a close relationship between phonological working memory and language abilities in normal children and children with language developmental disorders, such as those with cochlear implants. A review of these studies would clarify communication and learning in such children and provide more comprehensive information regarding their education and treatment. In this study, the characteristics of phonological working memory and its relationship with language abilities in children with cochlear implants was examined.Recent Findings: In this study, the authors studied the characteristics of phonological working memory and its relationship with language abilities of children with cochlear implants. These studies showed that in addition to demographic variables, phonological working memory is a factor that affects language development in children with cochlear implants. Children with cochlear implants typically have a shorter memory span.Conclusion: It is thought that the deficiency in primary auditory sensory input and language stimulation caused by difficulties in the processing and rehearsal of auditory information in phonological working memory is the main cause of the short memory span in such children. Conversely, phonological working memory problems may have adverse effects on the language abilities in such children. Therefore, to provide comprehensive and appropriate treatment for children with cochlear implants, the reciprocal relationship between language abilities and phonological working memory should be considered.

  13. Communication, Psychosocial, and Educational Outcomes of Children with Cochlear Implants and Challenges Remaining for Professionals and Parents

    Directory of Open Access Journals (Sweden)

    Renée Punch

    2011-01-01

    Full Text Available This paper provides an overview and a synthesis of the findings of a large, multifaceted study investigating outcomes from paediatric cochlear implantation. The study included children implanted at several Australian implant clinics and attending a variety of early intervention and educational settings across a range of locations in eastern Australia. It investigated three major aspects of childhood cochlear implantation: (1 parental expectations of their children's implantation, (2 families' decision-making processes, and (3 the communication, social, and educational outcomes of cochlear implantation for deaf children. It employed a mixed-methods approach in which quantitative survey data were gathered from 247 parents and 151 teachers, and qualitative data from semistructured interviews with 27 parents, 15 teachers, and 11 children and adolescents with cochlear implants. The summarised findings highlight several areas where challenges remain for implant clinics, parents, and educators if children with cochlear implants are to reach their full potential personally, educationally, and socially.

  14. Modeling of Auditory Neuron Response Thresholds with Cochlear Implants

    Directory of Open Access Journals (Sweden)

    Frederic Venail

    2015-01-01

    Full Text Available The quality of the prosthetic-neural interface is a critical point for cochlear implant efficiency. It depends not only on technical and anatomical factors such as electrode position into the cochlea (depth and scalar placement, electrode impedance, and distance between the electrode and the stimulated auditory neurons, but also on the number of functional auditory neurons. The efficiency of electrical stimulation can be assessed by the measurement of e-CAP in cochlear implant users. In the present study, we modeled the activation of auditory neurons in cochlear implant recipients (nucleus device. The electrical response, measured using auto-NRT (neural responses telemetry algorithm, has been analyzed using multivariate regression with cubic splines in order to take into account the variations of insertion depth of electrodes amongst subjects as well as the other technical and anatomical factors listed above. NRT thresholds depend on the electrode squared impedance (β = −0.11 ± 0.02, P<0.01, the scalar placement of the electrodes (β = −8.50 ± 1.97, P<0.01, and the depth of insertion calculated as the characteristic frequency of auditory neurons (CNF. Distribution of NRT residues according to CNF could provide a proxy of auditory neurons functioning in implanted cochleas.

  15. MRI of the labyrinth with volume rendering for cochlear implants candidates

    International Nuclear Information System (INIS)

    Sakata, Motomichi; Harada, Kuniaki; Shirase, Ryuji; Suzuki, Junpei; Nagahama, Hiroshi

    2009-01-01

    We demonstrated three-dimensional models of the labyrinth by volume rendering (VR) in preoperative assessment for cochlear implantation. MRI data sets were acquired in selected subjects using three-dimensional-fast spin echo sequences (3D-FSE). We produced the three-dimensional models of the labyrinth from axial heavily T2-weighted images. The three-dimensional models distinguished the scala tympani and scala vestibuli and provided multidirectional images. The optimal threshold three-dimensional models clearly showed the focal region of signal loss in the cochlear turns (47.1%) and the presence of inner ear anomalies (17.3%) in our series of patients. This study was concluded that these three-dimensional models by VR provide the oto-surgeon with precise, detailed, and easily interpreted information about the cochlear turns for cochlear implants candidates. (author)

  16. Technological, biological, and acoustical constraints to music perception in cochlear implant users.

    Science.gov (United States)

    Limb, Charles J; Roy, Alexis T

    2014-02-01

    Despite advances in technology, the ability to perceive music remains limited for many cochlear implant users. This paper reviews the technological, biological, and acoustical constraints that make music an especially challenging stimulus for cochlear implant users, while highlighting recent research efforts to overcome these shortcomings. The limitations of cochlear implant devices, which have been optimized for speech comprehension, become evident when applied to music, particularly with regards to inadequate spectral, fine-temporal, and dynamic range representation. Beyond the impoverished information transmitted by the device itself, both peripheral and central auditory nervous system deficits are seen in the presence of sensorineural hearing loss, such as auditory nerve degeneration and abnormal auditory cortex activation. These technological and biological constraints to effective music perception are further compounded by the complexity of the acoustical features of music itself that require the perceptual integration of varying rhythmic, melodic, harmonic, and timbral elements of sound. Cochlear implant users not only have difficulty perceiving spectral components individually (leading to fundamental disruptions in perception of pitch, melody, and harmony) but also display deficits with higher perceptual integration tasks required for music perception, such as auditory stream segregation. Despite these current limitations, focused musical training programs, new assessment methods, and improvements in the representation and transmission of the complex acoustical features of music through technological innovation offer the potential for significant advancements in cochlear implant-mediated music perception. Copyright © 2013 Elsevier B.V. All rights reserved.

  17. Surgical complications following cochlear implantation in adults based on a proposed reporting consensus

    DEFF Research Database (Denmark)

    Jeppesen, Jonas; Faber, Christian Emil

    2013-01-01

    Abstract Conclusion: The rate of severe complications was low and cochlear implantation is a relatively safe procedure. Standardization is crucial when reporting on cochlear implant complications to ensure comparability between studies. A consensus on the reporting of complications proposed by a ...... occurred following one implantation (0.3%). Transient chorda tympani syndrome (30.8%), vertigo/dizziness (29.5%) and tinnitus (4.9%) were the most frequent minor complications....

  18. Comparison of self-esteem level of adolescents with cochlear implant and normal hearing.

    Science.gov (United States)

    Sahli, Sanem; Belgin, Erol

    2006-09-01

    The purpose of this study is to compare the levels of self-esteem of adolescents with cochlear implants (before and after cochlear implantation) and the ones who have normal hearing. For this purpose, Rosenberg self-esteem scale is applied upon the study group which consists of 30 adolescents with cochlear implant between the ages of 12-19 and upon the control group which consists of 60 adolescents having the similar characteristics. The scale is used to evaluate the level of self-esteem of adolescents with cochlear implant and with normal hearing. At the end of the application, the scores of these two groups which they got according to their answers were compared statistically. When the results were examined, there seemed to be no significant difference statistically between the self-esteem values of the cochlear implant group and the control group. Apart from this, there seemed to be significant difference statistically between the self-esteem values of the before cochlear implantation and control group. In this study, we examined changes in the level of self-esteem according to different variables. As a result, it was found out that in both groups levels of self-esteem was higher for adolescents who had had preschool education, had brothers/sisters, high level of income, whose mother was working and whose father and mother had higher levels of education. On the other hand, the birth sequence and the child's father's profession did not seem to have any effect on the child's level of self-esteem. As a result of these findings, it was thought that cochlear implantation had a positive effect on life quality and it was suggested that the adolescents and their families should get assistance from experts about the characteristics and principles of approaching the child in this period. The adolescent should be directed towards social activities and courses, their positive sides should be supported and further studies should be carried out with different case groups on

  19. Cochlear implant: what the radiologist should know; Implante coclear: o que o radiologista precisa saber

    Energy Technology Data Exchange (ETDEWEB)

    Gomes, Natalia Delage; Couto, Caroline Laurita Batista; Gaiotti, Juliana Oggioni; Costa, Ana Maria Doffemond; Ribeiro, Marcelo Almeida; Diniz, Renata Lopes Furletti Caldeira, E-mail: nataliadelagegomes@gmail.com [Hospital Mater Dei, Belo Horizonte, MG (Brazil). Unidade de Radiologia e Diagnostico por Imagem

    2013-05-15

    Cochlear implant is the method of choice in the treatment of deep sensorineural hypoacusis, particularly in patients where conventional amplification devices do not imply noticeable clinical improvement. Imaging findings are crucial in the indication or contraindication for such surgical procedure. In the assessment of the temporal bone, radiologists should be familiar with relative or absolute contraindication factors, as well as with factors that might significantly complicate the implantation. Some criteria such as cochlear nerve aplasia, labyrinthine and/or cochlear aplasia are still considered as absolute contraindications, in spite of studies bringing such criteria into question. Cochlear dysplasias constitute relative contraindications, among them labyrinthitis ossificans is highlighted. Other alterations may be mentioned as complicating agents in the temporal bone assessment, namely, hypoplasia of the mastoid process, aberrant facial nerve, otomastoiditis, otosclerosis, dehiscent jugular bulb, enlarged endolymphatic duct and sac. The experienced radiologist assumes an important role in the evaluation of this condition. (author)

  20. Degradation of labial information modifies audiovisual speech perception in cochlear-implanted children.

    Science.gov (United States)

    Huyse, Aurélie; Berthommier, Frédéric; Leybaert, Jacqueline

    2013-01-01

    The aim of the present study was to examine audiovisual speech integration in cochlear-implanted children and in normally hearing children exposed to degraded auditory stimuli. Previous studies have shown that speech perception in cochlear-implanted users is biased toward the visual modality when audition and vision provide conflicting information. Our main question was whether an experimentally designed degradation of the visual speech cue would increase the importance of audition in the response pattern. The impact of auditory proficiency was also investigated. A group of 31 children with cochlear implants and a group of 31 normally hearing children matched for chronological age were recruited. All children with cochlear implants had profound congenital deafness and had used their implants for at least 2 years. Participants had to perform an /aCa/ consonant-identification task in which stimuli were presented randomly in three conditions: auditory only, visual only, and audiovisual (congruent and incongruent McGurk stimuli). In half of the experiment, the visual speech cue was normal; in the other half (visual reduction) a degraded visual signal was presented, aimed at preventing lipreading of good quality. The normally hearing children received a spectrally reduced speech signal (simulating the input delivered by the cochlear implant). First, performance in visual-only and in congruent audiovisual modalities were decreased, showing that the visual reduction technique used here was efficient at degrading lipreading. Second, in the incongruent audiovisual trials, visual reduction led to a major increase in the number of auditory based responses in both groups. Differences between proficient and nonproficient children were found in both groups, with nonproficient children's responses being more visual and less auditory than those of proficient children. Further analysis revealed that differences between visually clear and visually reduced conditions and between

  1. Facial nerve stimulation outcomes after cochlear implantation with cochlear-facial dehiscence

    Directory of Open Access Journals (Sweden)

    Christina H. Fang, MD

    2017-06-01

    Conclusion: Cochlear-facial dehiscence can predispose patients to post-implant FNS. Prior temporal bone irradiation may carry a higher risk of FNS. We recommend scrutiny for CFD in CTs of CI candidates and appropriate risk counseling for FNS if CFD is discovered and more frequent monitoring for FNS by audiology.

  2. Cochlear implantation in children and adults in Switzerland.

    Science.gov (United States)

    Brand, Yves; Senn, Pascal; Kompis, Martin; Dillier, Norbert; Allum, John H J

    2014-02-04

    The cochlear implant (CI) is one of the most successful neural prostheses developed to date. It offers artificial hearing to individuals with profound sensorineural hearing loss and with insufficient benefit from conventional hearing aids. The first implants available some 30 years ago provided a limited sensation of sound. The benefit for users of these early systems was mostly a facilitation of lip-reading based communication rather than an understanding of speech. Considerable progress has been made since then. Modern, multichannel implant systems feature complex speech processing strategies, high stimulation rates and multiple sites of stimulation in the cochlea. Equipped with such a state-of-the-art system, the majority of recipients today can communicate orally without visual cues and can even use the telephone. The impact of CIs on deaf individuals and on the deaf community has thus been exceptional. To date, more than 300,000 patients worldwide have received CIs. In Switzerland, the first implantation was performed in 1977 and, as of 2012, over 2,000 systems have been implanted with a current rate of around 150 CIs per year. The primary purpose of this article is to provide a contemporary overview of cochlear implantation, emphasising the situation in Switzerland.

  3. Speech recognition and communication outcomes with cochlear implantation in Usher syndrome type 3.

    Science.gov (United States)

    Pietola, Laura; Aarnisalo, Antti A; Abdel-Rahman, Akram; Västinsalo, Hanna; Isosomppi, Juha; Löppönen, Heikki; Kentala, Erna; Johansson, Reijo; Valtonen, Hannu; Vasama, Juha-Pekka; Sankila, Eeva-Marja; Jero, Jussi

    2012-01-01

    Usher syndrome Type 3 (USH3) is an autosomal recessive disorder characterized by variable type and degree of progressive sensorineural hearing loss and retinitis pigmentosa. Cochlear implants are widely used among these patients. To evaluate the results and benefits of cochlear implantation in patients with USH3. A nationwide multicenter retrospective review. During the years 1995-2005, in 5 Finnish university hospitals, 19 patients with USH3 received a cochlear implant. Saliva samples were collected to verify the USH3 genotype. Patients answered to 3 questionnaires: Glasgow Benefit Inventory, Glasgow Health Status Inventory, and a self-made questionnaire. Audiological data were collected from patient records. All the patients with USH3 in the study were homozygous for the Finnish major mutation (p.Y176X). Either they had severe sensorineural hearing loss or they were profoundly deaf. The mean preoperative hearing level (pure-tone average, 0.5-4 kHz) was 110 ± 8 dB hearing loss (HL) and the mean aided hearing level was 58 ± 11 dB HL. The postoperative hearing level (34 ± 9 dB HL) and word recognition scores were significantly better than before surgery. According to the Glasgow Benefit Inventory scores and Glasgow Health Status Inventory data related to hearing, the cochlear implantation was beneficial to patients with USH3. Cochlear implantation is beneficial to patients with USH3, and patients learn to use the implant without assistance.

  4. Automatic Model Generation Framework for Computational Simulation of Cochlear Implantation

    DEFF Research Database (Denmark)

    Mangado Lopez, Nerea; Ceresa, Mario; Duchateau, Nicolas

    2016-01-01

    . To address such a challenge, we propose an automatic framework for the generation of patient-specific meshes for finite element modeling of the implanted cochlea. First, a statistical shape model is constructed from high-resolution anatomical μCT images. Then, by fitting the statistical model to a patient......'s CT image, an accurate model of the patient-specific cochlea anatomy is obtained. An algorithm based on the parallel transport frame is employed to perform the virtual insertion of the cochlear implant. Our automatic framework also incorporates the surrounding bone and nerve fibers and assigns......Recent developments in computational modeling of cochlear implantation are promising to study in silico the performance of the implant before surgery. However, creating a complete computational model of the patient's anatomy while including an external device geometry remains challenging...

  5. Influence of hearing age and understanding verbal instructions in children with cochlear implants

    Directory of Open Access Journals (Sweden)

    Đoković Sanja

    2013-01-01

    Full Text Available Hearing age is defined as a period of using any amplification. Most researches indicate that hearing age influences the developmental rate of auditory and speech-language abilities in deaf children, especially when cochlear implantation was performed before the age of three. This research is aimed at analyzing the influence of hearing age on understanding verbal instructions in children with cochlear implants. The sample consists of 23 children with cochlear implants and 21 children with normal hearing, aged between 4 and 10. Hearing age of children with cochlear implants was between 2 and 7 years. Token Test with toys, adapted for children with hearing impairments, was used to analyze understanding verbal instructions. The results indicate that there are statistically significant differences between children with cochlear implants and children with normal hearing, aged between 4 and 7, on all subtests and the total score regardless of the hearing age (sub1 p<0.001, sub2 p<0.000, sub3 p<0.001, total score p<0.000. No statistically significant differences were determined on any of the subtests in children aged between 7.1 and 10, regardless of the hearing age. Comparative results analysis within the experimental group of children with different hearing age indicates that the difference in understanding verbal instructions between these two groups is not statistically significant.

  6. Prevention and management of vascular complications in middle ear and cochlear implant surgery.

    Science.gov (United States)

    Di Lella, Filippo; Falcioni, Maurizio; Piccinini, Silvia; Iaccarino, Ilaria; Bacciu, Andrea; Pasanisi, Enrico; Cerasti, Davide; Vincenti, Vincenzo

    2017-11-01

    The objective of this study is to illustrate prevention strategies and management of vascular complications from the jugular bulb (JB) and internal carotid artery (ICA) during middle ear surgery or cochlear implantation. The study design is retrospective case series. The setting is tertiary referral university hospital. Patients were included if presented pre- or intraoperative evidence of high-risk anatomical anomalies of ICA or JB during middle ear or cochlear implant surgery, intraoperative vascular injury, or revision surgery after the previous iatrogenic vascular lesions. The main outcome measures are surgical outcomes and complications rate. Ten subjects were identified: three underwent cochlear implant surgery and seven underwent middle ear surgery. Among the cochlear implant patients, two presented with anomalies of the JB impeding access to the cochlear lumen and one underwent revision surgery for incorrect positioning of the array in the carotid canal. Subtotal petrosectomy was performed in all cases. Anomalies of the JB were preoperatively identified in two patients with attic and external auditory canal cholesteatoma, respectively. In a patient, a high and dehiscent JB was found during myringoplasty, while another underwent revision surgery after iatrogenic injury of the JB. A dehiscent ICA complicated middle ear effusion in one case, while in another case, a carotid aneurysm determined a cholesterol granuloma. Rupture of a pseudoaneurysm of the ICA occurred in a child during second-stage surgery and required permanent balloon occlusion without neurological complications. Knowledge of normal anatomy and its variants and preoperative imaging are the basis for prevention of vascular complications during middle ear or cochlear implant surgery.

  7. Neurocognitive testing and cochlear implantation: insights into performance in older adults

    Directory of Open Access Journals (Sweden)

    Cosetti MK

    2016-05-01

    Full Text Available Maura K Cosetti,1,2 James B Pinkston,3 Jose M Flores,4 David R Friedmann,5 Callie B Jones,3 J Thomas Roland Jr,5,6 Susan B Waltzman5 1Department of Otolaryngology – Head and Neck Surgery, 2Department of Neurosurgery, 3Department of Neurology, Louisiana State University Health Sciences Center, Shreveport, LA, 4Department of Epidemiology, Johns Hopkins Bloomberg School of Public Health, Baltimore, MA, 5Department of Otolaryngology, 6Department of Neurosurgery, New York University School of Medicine, New York, NY, USA Objective: The aim of this case series was to assess the impact of auditory rehabilitation with cochlear implantation on the cognitive function of elderly patients over time. Design: This is a longitudinal case series of prospective data assessing neurocognitive function and speech perception in an elderly cohort pre- and post-implantation. Setting: University cochlear implant center. Participants: The patients were post-lingually deafened elderly female (mean, 73.6 years; SD, 5.82; range, 67–81 years cochlear implant recipients (n=7. Measurements: A neurocognitive battery of 20 tests assessing intellectual function, learning, short- and long-term memory, verbal fluency, attention, mental flexibility, and processing speed was performed prior to and 2–4.1 years (mean, 3.7 after cochlear implant (CI. Speech perception testing using Consonant–Nucleus–Consonant words was performed prior to implantation and at regular intervals postoperatively. Individual and aggregate differences in cognitive function pre- and post-CI were estimated. Logistic regression with cluster adjustment was used to estimate the association (%improvement or %decline between speech understanding and years from implantation at 1 year, 2 years, and 3 years post-CI. Results: Improvements after CI were observed in 14 (70% of all subtests administered. Declines occurred in five (25% subtests. In 55 individual tests (43%, post-CI performance improved

  8. Advances in cochlear implant telemetry: evoked neural responses, electrical field imaging, and technical integrity.

    NARCIS (Netherlands)

    Mens, L.H.M.

    2007-01-01

    During the last decade, cochlear implantation has evolved into a well-established treatment of deafness, predominantly because of many improvements in speech processing and the controlled excitation of the auditory nerve. Cochlear implants now also feature telemetry, which is highly useful to

  9. Hearing Preservation after Cochlear Implantation: UNICAMP Outcomes

    Directory of Open Access Journals (Sweden)

    Guilherme Machado de Carvalho

    2013-01-01

    Full Text Available Background. Electric-acoustic stimulation (EAS is an excellent choice for people with residual hearing in low frequencies but not high frequencies and who derive insufficient benefit from hearing aids. For EAS to be effective, subjects' residual hearing must be preserved during cochlear implant (CI surgery. Methods. We implanted 6 subjects with a CI. We used a special surgical technique and an electrode designed to be atraumatic. Subjects' rates of residual hearing preservation were measured 3 times postoperatively, lastly after at least a year of implant experience. Subjects' aided speech perception was tested pre- and postoperatively with a sentence test in quiet. Subjects' subjective responses assessed after a year of EAS or CI experience. Results. 4 subjects had total or partial residual hearing preservation; 2 subjects had total residual hearing loss. All subjects' hearing and speech perception benefited from cochlear implantation. CI diminished or eliminated tinnitus in all 4 subjects who had it preoperatively. 5 subjects reported great satisfaction with their new device. Conclusions. When we have more experience with our surgical technique we are confident we will be able to report increased rates of residual hearing preservation. Hopefully, our study will raise the profile of EAS in Brazil and Latin/South America.

  10. Children using Cochlear Implants Capitalize on Acoustical Hearing for Music Perception

    Directory of Open Access Journals (Sweden)

    Talar eHopyan

    2012-10-01

    Full Text Available Cochlear implants (CIs electrically stimulate the auditory nerve providing children who are deaf with access to speech and music. Because of device limitations, it was hypothesized that children using CIs develop abnormal perception of musical cues. Perception of pitch and rhythm as well as memory for music was measured by the children’s version of the Montreal Battery of Amusia (MBEA in 23 unilateral CI users and 22 age-matched children with normal hearing. Children with CIs were less accurate than their normal hearing peers (p<0.05. CI users were best able to discern rhythm changes (p < .01 and to remember musical pieces (p < .01. Contrary to expectations, abilities to hear cues in music improved as the age at implantation increased (p < .01. Further analyses revealed that this was because the children implanted at older ages also had better low frequency hearing prior to cochlear implantation and were able to use this hearing prior to cochlear implantation by wearing hearing aids. Access to early acoustical hearing in the lower frequency ranges appears to establish a base for music perception, which can be accessed with later electrical CI hearing.

  11. Complications in cochlear implantation at the Clinical Center of Vojvodina

    Directory of Open Access Journals (Sweden)

    Dankuc Dragan

    2015-01-01

    Full Text Available Introduction. The first modern cochlear implantation in Serbia was performed on November 26, 2002 at the Center for Cochlear Implantation of the Clinic for Ear, Nose and Throat Diseases, Clinical Center of Vojvodina. Objective. The aim of the paper is the analysis of intraoperative and postoperative complications. Major complications include those resulting in the necessity for revision surgery, explantation, reimplantation, severe disease or even lethal outcomes. Minor complications resolve spontaneously or can be managed by conservative therapy and do not require any prolonged hospitalization of the patient. Methods. In the 2002-2013 period, 99 patients underwent surgical procedures and 100 cochlear implants were placed. Both intraoperative and postoperative complications were analyzed in the investigated patient population. Results. The analysis encompassed 99 patients, the youngest and the oldest ones being one year old and 61 years old, respectively. The complications were noticed in 11 patients, i.e. in 10.5% of 105 surgical procedures. The majority of procedures (89.5% were not accompanied by any post-surgical complications. Unsuccessful implantation in a single-step procedure (4.04% and transient facial nerve paralysis can be considered most frequent among our patients, whereas cochlear ossification (1.01% and transient ataxia (2.02% occurred rarely. Stimulation of the facial nerve (1.01%, intraoperative perilymph liquid gusher (1.01%, device failure and late infections (1.01% were recorded extremely rarely. Conclusion. Complications such as electrode extrusion, skin necrosis over the implant or meningitis, which is considered the most severe postoperative complication, have not been recorded at our Center since the very beginning. Absence of postoperative meningitis in patients treated at the Center can be attributed to timely pneumococcal vaccination of children.

  12. Electroacoustic verification of frequency modulation systems in cochlear implant users.

    Science.gov (United States)

    Fidêncio, Vanessa Luisa Destro; Jacob, Regina Tangerino de Souza; Tanamati, Liége Franzini; Bucuvic, Érika Cristina; Moret, Adriane Lima Mortari

    2017-12-26

    The frequency modulation system is a device that helps to improve speech perception in noise and is considered the most beneficial approach to improve speech recognition in noise in cochlear implant users. According to guidelines, there is a need to perform a check before fitting the frequency modulation system. Although there are recommendations regarding the behavioral tests that should be performed at the fitting of the frequency modulation system to cochlear implant users, there are no published recommendations regarding the electroacoustic test that should be performed. Perform and determine the validity of an electroacoustic verification test for frequency modulation systems coupled to different cochlear implant speech processors. The sample included 40 participants between 5 and 18 year's users of four different models of speech processors. For the electroacoustic evaluation, we used the Audioscan Verifit device with the HA-1 coupler and the listening check devices corresponding to each speech processor model. In cases where the transparency was not achieved, a modification was made in the frequency modulation gain adjustment and we used the Brazilian version of the "Phrases in Noise Test" to evaluate the speech perception in competitive noise. It was observed that there was transparency between the frequency modulation system and the cochlear implant in 85% of the participants evaluated. After adjusting the gain of the frequency modulation receiver in the other participants, the devices showed transparency when the electroacoustic verification test was repeated. It was also observed that patients demonstrated better performance in speech perception in noise after a new adjustment, that is, in these cases; the electroacoustic transparency caused behavioral transparency. The electroacoustic evaluation protocol suggested was effective in evaluation of transparency between the frequency modulation system and the cochlear implant. Performing the adjustment of

  13. Cochlear implantation in the Mondini inner ear malformation.

    Science.gov (United States)

    Miyamoto, R T; Robbins, A J; Myres, W A; Pope, M L

    1986-07-01

    We report the case of a profoundly deaf 4-year-old boy with congenital deafness as a result of Mondini's dysplasia. The Mondini inner ear malformation is the result of arrested labyrinthine development during embryogenesis and is characterized by both bony and membranous anomalies of the inner ear. The dysplastic cochlear anatomy does not preclude successful cochlear implantation, and electrical threshold measurements are similar to those recorded in pediatric subjects deafened as a result of other causes.

  14. Cochlear implant users' spectral ripple resolution.

    Science.gov (United States)

    Jeon, Eun Kyung; Turner, Christopher W; Karsten, Sue A; Henry, Belinda A; Gantz, Bruce J

    2015-10-01

    This study revisits the issue of the spectral ripple resolution abilities of cochlear implant (CI) users. The spectral ripple resolution of recently implanted CI recipients (implanted during the last 10 years) were compared to those of CI recipients implanted 15 to 20 years ago, as well as those of normal-hearing and hearing-impaired listeners from previously published data from Henry, Turner, and Behrens [J. Acoust. Soc. Am. 118, 1111-1121 (2005)]. More recently, implanted CI recipients showed significantly better spectral ripple resolution. There is no significant difference in spectral ripple resolution for these recently implanted subjects compared to hearing-impaired (acoustic) listeners. The more recently implanted CI users had significantly better pre-operative speech perception than previously reported CI users. These better pre-operative speech perception scores in CI users from the current study may be related to better performance on the spectral ripple discrimination task; however, other possible factors such as improvements in internal and external devices cannot be excluded.

  15. Gender Categorization in Cochlear Implant Users

    Science.gov (United States)

    Massida, Zoe; Marx, Mathieu; Belin, Pascal; James, Christopher; Fraysse, Bernard; Barone, Pascal; Deguine, Olivier

    2013-01-01

    Purpose: In this study, the authors examined the ability of subjects with cochlear implants (CIs) to discriminate voice gender and how this ability evolved as a function of CI experience. Method: The authors presented a continuum of voice samples created by voice morphing, with 9 intermediate acoustic parameter steps between a typical male and a…

  16. Electrode selection for hearing preservation in cochlear implantation: A review of the evidence

    Directory of Open Access Journals (Sweden)

    Jason A. Brant

    2016-09-01

    Full Text Available Objective: To review and assess the ideal length of electrode in cochlear implant patients for hearing preservation. Methods: The English language literature was reviewed for studies including hearing preservation and speech understanding for electrodes of different lengths. Results: One prospective trial was found, and there were no studies that randomized patients into different length electrodes with an intent to preserve hearing. Eight studies total included multiple length electrodes and contained data regarding hearing preservation. Conclusions: Although there is some evidence that indicates that shorter electrodes may improve both short and long-term hearing preservation rates in cochlear implant patients, no study has directly compared implant length on hearing preservation in a similar patient population. A randomized trial of short and standard length electrodes for hearing preservation is warranted. In the interim, utilization of current electrodes measuring 20–25 mm could seem to be a prudent approach when seeking to preserve residual hearing without unduly compromising cochlear coverage. Keywords: Electrode, Length, Hearing preservation, Cochlear implantation

  17. The comparison of balance performance among children with cochlear implantation, post-aural aid and normal children

    Directory of Open Access Journals (Sweden)

    Arezoo Ahmad pour

    2014-11-01

    Full Text Available Background: This cross-sectional study was carried out to compare balance performance between children with cochlear implants and post-aural aid and normal children. Methods: The present study was done on 67 severe to profound hearing impaired children. Of these, 21 children with an average age of 7 years and 4 months (±1.7 wore cochlear implant, 46 children with an average age of 7 years and 7 months (±1.7 wore post-aural aid and 60 children with an average 8 years and one month (±11 months were considered as a control group. All of the children were tested with the 9-stage balance subtest of Bruininks-Oseretsky Test of Motor Proficiency2 (BOT2. Results: The mean total BOT2 score of hearing impaired children was significantly lower than the normal group (P≤0.001. The mean total BOT2 score among children with cochlear implant, post-aural aids and normal group showed that cochlear implant group significantly performed weaker than the other two groups (P≤0.001. Conclusion: Hearing impaired children particularly children with cochlear implant are exposed to the risk of balance deficit. Hearing impaired children specially those who wear cochlear implants must be screened for vestibular hypofunction.

  18. Predicting social functioning in children with a cochlear implant and in normal-hearing children: the role of emotion regulation.

    Science.gov (United States)

    Wiefferink, Carin H; Rieffe, Carolien; Ketelaar, Lizet; Frijns, Johan H M

    2012-06-01

    The purpose of the present study was to compare children with a cochlear implant and normal hearing children on aspects of emotion regulation (emotion expression and coping strategies) and social functioning (social competence and externalizing behaviors) and the relation between emotion regulation and social functioning. Participants were 69 children with cochlear implants (CI children) and 67 normal hearing children (NH children) aged 1.5-5 years. Parents answered questionnaires about their children's language skills, social functioning, and emotion regulation. Children also completed simple tasks to measure their emotion regulation abilities. Cochlear implant children had fewer adequate emotion regulation strategies and were less socially competent than normal hearing children. The parents of cochlear implant children did not report fewer externalizing behaviors than those of normal hearing children. While social competence in normal hearing children was strongly related to emotion regulation, cochlear implant children regulated their emotions in ways that were unrelated with social competence. On the other hand, emotion regulation explained externalizing behaviors better in cochlear implant children than in normal hearing children. While better language skills were related to higher social competence in both groups, they were related to fewer externalizing behaviors only in cochlear implant children. Our results indicate that cochlear implant children have less adequate emotion-regulation strategies and less social competence than normal hearing children. Since they received their implants relatively recently, they might eventually catch up with their hearing peers. Longitudinal studies should further explore the development of emotion regulation and social functioning in cochlear implant children. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  19. The acquisition of personal pronouns in cochlear-implanted children

    NARCIS (Netherlands)

    Verbist, Annemie Josee Jozef

    2010-01-01

    Today, many deaf children can be given access to oral language thanks to a cochlear implant, a surgically implanted electronic device that provides a sense of sound thanks to electric stimulation of the auditory nerve. In this study, the acquisition of personal pronouns is considered to be a measure

  20. Usher syndrome and cochlear implantation.

    Science.gov (United States)

    Loundon, Natalie; Marlin, Sandrine; Busquet, Denise; Denoyelle, Françoise; Roger, Gilles; Renaud, Francis; Garabedian, Erea Noel

    2003-03-01

    To evaluate the symptoms leading to diagnosis and the quality of rehabilitation after cochlear implantation in Usher syndrome. Retrospective cohort study. ENT department of a tertiary referral hospital. Among 210 patients given an implantation in the Ear, Nose, and Throat department, 185 were congenitally deaf and 13 had Usher syndrome (7.0%). Five had a family history of Usher, and eight were sporadic cases. Eleven cases were Usher type I, one was Usher type III, and one was not classified. The age at implantation ranged from 18 months to 44 years (mean, 6 years 1 month). The mean follow-up was 52 months (range, 9 months to 9 years). All patients had audiophonological and clinical examination, computed tomography scan of the temporal bones, ophthalmologic examination with fundoscopy, and an electroretinogram. Cerebral magnetic resonance imaging and vestibular examination were performed in 9 of 13 and 10 of 13 cases, respectively. Logopedic outcome measured preimplant and postimplant closed- and open-set word recognition and oral expression at follow-up. The most frequent initial sign of Usher syndrome was delayed walking, with a mean age of 20 months. Among the 172 other congenitally deaf children with implants, when deafness was not associated with other neurologic disorders, the mean age at walking was 14 months (p < 0.001). The fundoscopy was always abnormal after the age of 5 years, and the electroretinogram was abnormal in all cases. Vestibular function was abnormal in all but one case (nonclassified). The computed tomography scan and the magnetic resonance imaging were always normal. Logopedic results with cochlear implants showed good perception skills in all but one case. The best perceptive results were obtained in children implanted before the age of 9 years. Oral language had significantly progressed in 9 of 13 at follow-up. There was no relation between the visual acuity and the logopedic results. The earliest clinical sign associated with deafness

  1. Short-term risk of falling after cochlear implantation.

    Science.gov (United States)

    Stevens, Madelyn N; Baudhuin, Jacqueline E; Hullar, Timothy E

    2014-01-01

    Cochlear implantation is a highly effective intervention for hearing loss, but insertion of an implant into the cochlea is often accompanied by loss of residual hearing function. Sometimes, postoperative testing also shows loss of function in the semicircular canals or otolith organs. The effect of this loss on equilibrium, particularly in the short term following surgery, and the risk of falling due to this loss is unknown. We prospectively measured balance in 16 consecutive adult cochlear implant patients before and 2 weeks after surgery. Subjects stood on a foam pad with eyes closed, feet together and arms at the side. The length of time over which this posture could be maintained was recorded up to a maximum value of 30 s indicating normal performance. Ten of 16 subjects reached a maximal time on preoperative testing. Nine of 16 subjects lost balance function after surgery. Four of the 10 subjects with normal preoperative balance function lost function. Subjects older than the age of 60 were more likely to lose balance function than younger subjects. We used previously published values relating balance performance on foam to risk of falling to calculate the fall risk among our subjects. The relative risk of falling increased after surgery by more than threefold in some patients. Imbalance after cochlear implantation may be much more common, particularly in the short term, than previously appreciated. This imbalance is accompanied by an increased risk of falling in many patients. Careful preoperative counseling before implantation and postoperative therapeutic intervention to improve comfort and reduce the chance of falling may be warranted, particularly in patients at a risk for injuries from falls (level of evidence: 2b). © 2014 S. Karger AG, Basel.

  2. [The Russian-language version of the matrix test (RUMatrix) in free field in patients after cochlear implantation in the long term].

    Science.gov (United States)

    Goykhburg, M V; Bakhshinyan, V V; Petrova, I P; Wazybok, A; Kollmeier, B; Tavartkiladze, G A

    The deterioration of speech intelligibility in the patients using cochlear implantation (CI) systems is especially well apparent in the noisy environment. It explains why phrasal speech tests, such as a Matrix sentence test, have become increasingly more popular in the speech audiometry during rehabilitation after CI. The Matrix test allows to estimate speech perception by the patients in a real life situation. The objective of this study was to assess the effectiveness of audiological rehabilitation of CI patients using the Russian-language version of the matrix test (RUMatrix) in free field in the noisy environment. 33 patients aged from 5 to 40 years with a more than 3 year experience of using cochlear implants inserted at the National Research Center for Audiology and Hearing Rehabilitation were included in our study. Five of these patients were implanted bilaterally. The results of our study showed a statistically significant improvement of speech intelligibility in the noisy environment after the speech processor adjustment; dynamics of the signal-to-noise ratio changes was -1.7 dB (planguages makes possible its application in international multicenter studies.

  3. Electrophysiological evidence for altered visual, but not auditory, selective attention in adolescent cochlear implant users.

    Science.gov (United States)

    Harris, Jill; Kamke, Marc R

    2014-11-01

    Selective attention fundamentally alters sensory perception, but little is known about the functioning of attention in individuals who use a cochlear implant. This study aimed to investigate visual and auditory attention in adolescent cochlear implant users. Event related potentials were used to investigate the influence of attention on visual and auditory evoked potentials in six cochlear implant users and age-matched normally-hearing children. Participants were presented with streams of alternating visual and auditory stimuli in an oddball paradigm: each modality contained frequently presented 'standard' and infrequent 'deviant' stimuli. Across different blocks attention was directed to either the visual or auditory modality. For the visual stimuli attention boosted the early N1 potential, but this effect was larger for cochlear implant users. Attention was also associated with a later P3 component for the visual deviant stimulus, but there was no difference between groups in the later attention effects. For the auditory stimuli, attention was associated with a decrease in N1 latency as well as a robust P3 for the deviant tone. Importantly, there was no difference between groups in these auditory attention effects. The results suggest that basic mechanisms of auditory attention are largely normal in children who are proficient cochlear implant users, but that visual attention may be altered. Ultimately, a better understanding of how selective attention influences sensory perception in cochlear implant users will be important for optimising habilitation strategies. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  4. Wired to freedom: Life science, public politics, and the case of Cochlear Implantation.

    Science.gov (United States)

    Jepsen, Kim Sune; Bertilsson, T Margareta

    2017-02-01

    Cochlear Implantation is now regarded as the most successful medical technology. It carries promises to provide deaf/hearing impaired individuals with a technological sense of hearing and an access to participate on a more equal level in social life. In this article, we explore the adoption of cochlear implantations among Danish users in order to shed more light on their social and political implications. We situate cochlear implantation in a framework of new life science advances, politics, and user experiences. Analytically, we draw upon the notion of social imaginary and explore the social dimension of life science through a notion of public politics adopted from the political theory of John Dewey. We show how cochlear implantation engages different social imaginaries on the collective and individual levels and we suggest that users share an imaginary of being "wired to freedom" that involves new access to social life, continuous communicative challenges, common practices, and experiences. In looking at their lives as "wired to freedom," we hope to promote a wider spectrum of civic participation in the benefit of future life science developments within and beyond the field of Cochlear Implantation. As our empirical observations are largely based in the Scandinavian countries (notably Denmark), we also provide some reflections on the character of the technology-friendly Scandinavian welfare states and the unintended consequences that may follow in the wake of rapid technology implementation of life science in society.

  5. Segmental analysis of cochlea on three-dimensional MR imaging and high-resolution CT. Application to pre-operative assessment of cochlear implant candidates

    International Nuclear Information System (INIS)

    Akiba, Hidenari; Himi, Tetsuo; Hareyama, Masato

    2002-01-01

    High-resolution computed tomography (HRCT) and magnetic resonance imaging (MRI) have recently become standard pre-operative examinations for cochlear implant candidates. HRCT can demonstrate ossification and narrowing of the cochlea, but subtle calcification or soft tissue obstruction may not be detected by this method alone, and so conventional T2 weighted image (T2WI) on MRI has been recommended to disclose them. In this study, segmental analyses of the cochlea were made on three-dimensional MRI (3DMRI) and HRCT in order to predict cochlear implant difficulties. The study involved 59 consecutive patients with bilateral profound sensorineural hearing loss who underwent MRI and HRCT from November 1992 to February 1998. Etiologies of deafness were meningogenic labyrinthitis (n=9), tympanogenic labyrinthitis (n=12), and others (n=38). Pulse sequence of heavy T2WI was steady state free precession and 3DMRI was reconstructed by maximum intensity projection method. HRCT was reconstructed by bone algorithm focusing on the temporal bone. For alternative segmental analysis, cochleas were anatomically divided into five parts and each of them was classified by three ranks of score depending on 3DMRI or HRCT findings. There was a close correlation by ranks between the total score of the five parts on 3DMRI and HRCT (rs=0.86, P<0.001), and a statistically significant difference was identified between causes of deafness in the total score on 3DMRI or HRCT (P<0.001, respectively). There was a significant difference in the score among the five parts on each examination (P<0.001, respectively), and abnormal findings were more frequent in the inferior horizontal part (IHP) of the basal turn. Of the 35 patients who underwent cochlear implantation, no one had ossification in the IHP on HRCT and only one patient had an obstacle to implantation. When no signal void in the IHP on 3DMRI and no ossification in the IHP on HRCT were assumed to be the criteria for candidacy for cochlear

  6. Cortical Plasticity after Cochlear Implantation

    DEFF Research Database (Denmark)

    Petersen, Bjørn; Gjedde, Albert; Wallentin, Mikkel

    2013-01-01

    recently implanted adult implant recipients listened to running speech or speech-like noise in four sequential PET sessions at each milestone. CI listeners with postlingual hearing loss showed differential activation of left superior temporal gyrus during speech and speech-like stimuli, unlike CI listeners...... with prelingual hearing loss. Furthermore, Broca's area was activated as an effect of time, but only in CI listeners with postlingual hearing loss. The study demonstrates that adaptation to the cochlear implant is highly related to the history of hearing loss. Speech processing in patients whose hearing loss...... occurred after the acquisition of language involves brain areas associated with speech comprehension, which is not the case for patients whose hearing loss occurred before the acquisition of language. Finally, the findings confirm the key role of Broca's area in restoration of speech perception, but only...

  7. Direct recordings from the auditory cortex in a cochlear implant user.

    Science.gov (United States)

    Nourski, Kirill V; Etler, Christine P; Brugge, John F; Oya, Hiroyuki; Kawasaki, Hiroto; Reale, Richard A; Abbas, Paul J; Brown, Carolyn J; Howard, Matthew A

    2013-06-01

    Electrical stimulation of the auditory nerve with a cochlear implant (CI) is the method of choice for treatment of severe-to-profound hearing loss. Understanding how the human auditory cortex responds to CI stimulation is important for advances in stimulation paradigms and rehabilitation strategies. In this study, auditory cortical responses to CI stimulation were recorded intracranially in a neurosurgical patient to examine directly the functional organization of the auditory cortex and compare the findings with those obtained in normal-hearing subjects. The subject was a bilateral CI user with a 20-year history of deafness and refractory epilepsy. As part of the epilepsy treatment, a subdural grid electrode was implanted over the left temporal lobe. Pure tones, click trains, sinusoidal amplitude-modulated noise, and speech were presented via the auxiliary input of the right CI speech processor. Additional experiments were conducted with bilateral CI stimulation. Auditory event-related changes in cortical activity, characterized by the averaged evoked potential and event-related band power, were localized to posterolateral superior temporal gyrus. Responses were stable across recording sessions and were abolished under general anesthesia. Response latency decreased and magnitude increased with increasing stimulus level. More apical intracochlear stimulation yielded the largest responses. Cortical evoked potentials were phase-locked to the temporal modulations of periodic stimuli and speech utterances. Bilateral electrical stimulation resulted in minimal artifact contamination. This study demonstrates the feasibility of intracranial electrophysiological recordings of responses to CI stimulation in a human subject, shows that cortical response properties may be similar to those obtained in normal-hearing individuals, and provides a basis for future comparisons with extracranial recordings.

  8. Temporal and spectral contributions to musical instrument identification and discrimination among cochlear implant users.

    Science.gov (United States)

    Prentiss, Sandra M; Friedland, David R; Fullmer, Tanner; Crane, Alison; Stoddard, Timothy; Runge, Christina L

    2016-09-01

    To investigate the contributions of envelope and fine-structure to the perception of timbre by cochlear implant (CI) users as compared to normal hearing (NH) listeners. This was a prospective cohort comparison study. Normal hearing and cochlear implant patients were tested. Three experiments were performed in sound field using musical notes altered to affect the characteristic pitch of an instrument and the acoustic envelope. Experiment 1 assessed the ability to identify the instrument playing each note, while experiments 2 and 3 assessed the ability to discriminate the different stimuli. Normal hearing subjects performed better than CI subjects in all instrument identification tasks, reaching statistical significance for 4 of 5 stimulus conditions. Within the CI population, acoustic envelope modifications did not significantly affect instrument identification or discrimination. With envelope and pitch cues removed, fine structure discrimination performance was similar between normal hearing and CI users for the majority of conditions, but some specific instrument comparisons were significantly more challenging for CI users. Cochlear implant users perform significantly worse than normal hearing listeners on tasks of instrument identification. However, cochlear implant listeners can discriminate differences in envelope and some fine structure components of musical instrument sounds as well as normal hearing listeners. The results indicated that certain fine structure cues are important for cochlear implant users to make discrimination judgments, and therefore may affect interpretation toward associating with a specific instrument for identification.

  9. Effect of age at cochlear implantation on auditory and speech development of children with auditory neuropathy spectrum disorder.

    Science.gov (United States)

    Liu, Yuying; Dong, Ruijuan; Li, Yuling; Xu, Tianqiu; Li, Yongxin; Chen, Xueqing; Gong, Shusheng

    2014-12-01

    To evaluate the auditory and speech abilities in children with auditory neuropathy spectrum disorder (ANSD) after cochlear implantation (CI) and determine the role of age at implantation. Ten children participated in this retrospective case series study. All children had evidence of ANSD. All subjects had no cochlear nerve deficiency on magnetic resonance imaging and had used the cochlear implants for a period of 12-84 months. We divided our children into two groups: children who underwent implantation before 24 months of age and children who underwent implantation after 24 months of age. Their auditory and speech abilities were evaluated using the following: behavioral audiometry, the Categories of Auditory Performance (CAP), the Meaningful Auditory Integration Scale (MAIS), the Infant-Toddler Meaningful Auditory Integration Scale (IT-MAIS), the Standard-Chinese version of the Monosyllabic Lexical Neighborhood Test (LNT), the Multisyllabic Lexical Neighborhood Test (MLNT), the Speech Intelligibility Rating (SIR) and the Meaningful Use of Speech Scale (MUSS). All children showed progress in their auditory and language abilities. The 4-frequency average hearing level (HL) (500Hz, 1000Hz, 2000Hz and 4000Hz) of aided hearing thresholds ranged from 17.5 to 57.5dB HL. All children developed time-related auditory perception and speech skills. Scores of children with ANSD who received cochlear implants before 24 months tended to be better than those of children who received cochlear implants after 24 months. Seven children completed the Mandarin Lexical Neighborhood Test. Approximately half of the children showed improved open-set speech recognition. Cochlear implantation is helpful for children with ANSD and may be a good optional treatment for many ANSD children. In addition, children with ANSD fitted with cochlear implants before 24 months tended to acquire auditory and speech skills better than children fitted with cochlear implants after 24 months. Copyright © 2014

  10. The cochlear implant and possibilities for narrowing the remaining gaps between prosthetic and normal hearing

    Directory of Open Access Journals (Sweden)

    Blake S. Wilson

    2017-12-01

    Full Text Available Background: The cochlear implant has become the standard of care for severe or worse losses in hearing and indeed has produced the first substantial restoration of a lost or absent human sense using a medical intervention. However, the devices are not perfect and many efforts to narrow the remaining gaps between prosthetic and normal hearing are underway. Objective: To assess the present status of cochlear implants and to describe possibilities for improving them. Results: The present-day devices work well in quiet conditions for the great majority of users. However, not all users have high levels of speech reception in quiet and nearly all users struggle with speech reception in typically noisy acoustic environments. In addition, perception of sounds more complex than speech, such as most music, is generally poor unless residual hearing at low frequencies can be stimulated acoustically in conjunction with the electrical stimuli provided by the implant. Possibilities for improving the present devices include increasing the spatial specificity of neural excitation by reducing masking effects or with new stimulus modes; prudent pruning of interfering or otherwise detrimental electrodes from the stimulation map; a further relaxation in the criteria for implant candidacy, based on recent evidence from persons with high levels of residual hearing and to allow many more people to benefit from cochlear implants; and “top down” or “brain centric” approaches to implant designs and applications. Conclusions: Progress in the development of the cochlear implant and related treatments has been remarkable but room remains for improvements. The future looks bright as there are multiple promising possibilities for improvements and many talented teams are pursuing them. Keywords: Auditory prosthesis, Cochlear implant, Cochlear prosthesis, Deafness, Neural prosthesis

  11. Qualitative case studies of five cochlear implant recipients' experience with music.

    Science.gov (United States)

    Bartel, Lee R; Greenberg, Simon; Friesen, Lendra M; Ostroff, Jodi; Bodmer, Daniel; Shipp, David; Chen, Joseph M

    2011-02-01

    Cochlear implantation has revolutionized the management of those who suffer from severe-to-profound hearing loss because many patients now achieve excellent speech understanding with objective testing. Nevertheless, speech understanding in noisy conditions and music appreciation remain significant challenges to cochlear implant (CI) users. Music appreciation is an extremely complex experience that is difficult to quantify through a conventional outcome study. This paper aims at documenting the experience of five CI patients with regard to music appreciation using qualitative techniques. This information was obtained through a semi-structured interview process. The interviews were then transcribed and analysed using a constant comparative method of qualitative description. The results together with medical case records were used to identify emerging themes. The common themes that evolved were: musical background, the experience of receiving the implant, current experience with music, attention, musical prediction ability, internal hearing, hedonic vs. critical listening, determination, and timbre perception. By documenting their experiences in this manner, novel insights into the patient perspective are provided that are unique to the literature. These descriptions will aid clinicians and researchers who work in the area of cochlear implantation to better understand the needs of their patients.

  12. The Construct Validity and Reliability of an Assessment Tool for Competency in Cochlear Implant Surgery

    Directory of Open Access Journals (Sweden)

    Patorn Piromchai

    2014-01-01

    Full Text Available Introduction. We introduce a rating tool that objectively evaluates the skills of surgical trainees performing cochlear implant surgery. Methods. Seven residents and seven experts performed cochlear implant surgery sessions from mastoidectomy to cochleostomy on a standardized virtual reality temporal bone. A total of twenty-eight assessment videos were recorded and two consultant otolaryngologists evaluated the performance of each participant using these videos. Results. Interrater reliability was calculated using the intraclass correlation coefficient for both the global and checklist components of the assessment instrument. The overall agreement was high. The construct validity of this instrument was strongly supported by the significantly higher scores in the expert group for both components. Conclusion. Our results indicate that the proposed assessment tool for cochlear implant surgery is reliable, accurate, and easy to use. This instrument can thus be used to provide objective feedback on overall and task-specific competency in cochlear implantation.

  13. Changes in Tinnitus after Cochlear Implantation and Its Relation with Psychological Functioning

    NARCIS (Netherlands)

    Kloostra, Francka J. J.; Arnold, Rosemarie; Hofman, Rutger; Van Dijk, Pim

    2015-01-01

    This study retrospectively assessed the prevalence of tinnitus in cochlear implant patients and the changes after implantation in 212 patients implanted between 2000 and 2009. Patients were included at least 6 months after implantation and received 2 sets of questionnaires, one about the situation

  14. Computational tool for postoperative evaluation of cochlear implant patients; Ferramenta computacional para avaliacao pos-operatoria de pacientes com implante coclear

    Energy Technology Data Exchange (ETDEWEB)

    Giacomini, Guilherme; Pavan, Ana Luiza M.; Pina, Diana R. de [Universidade Estadual Paulista Julio de Mesquita Filho (IBB/UNESP), Botucatu, SP (Brazil). Instituto de Biociencias; Altemani, Joao M.C.; Castilho, Arthur M. [Universidade Estadual de Campinas (HC/UNICAMP), Campinas, SP (Brazil). Hospital de Clinicas

    2016-07-01

    The aim of this study was to develop a tool to calculate the insertion depth angle of cochlear implants, from computed tomography exams. The tool uses different image processing techniques, such as thresholding and active contour. Then, we compared the average insertion depth angle of three different implant manufacturers. The developed tool can be used, in the future, to compare the insertion depth angle of the cochlear implant with postoperative response of patient's hearing. (author)

  15. Aspects of temporal bone anatomy and pathology in conjunction with cochlear implant surgery

    Energy Technology Data Exchange (ETDEWEB)

    Stjernholm, Christina [Karolinska Inst., Stockholm (Sweden). Soedersjukhuset

    2003-07-01

    Cochlear implantation is a treatment for patients with severe sensorineural hearing loss/deafness, who get no help from ordinary hearing aids. The cochlear implant is surgically placed under the skin near the ear and a very thin electrode array is introduced into the cochlea of the inner ear, where it stimulates the remaining nerve fibers. The operation is complicated; it is performed with the aid of a microscope, and involves drilling very close to vital vessels and important nerves. High resolution computed tomography (CT) of the temporal bone is a part of the preoperative evaluation preceding cochlear implantation. It is a method for visualizing the bony structures of the middle and inner ear - to diagnose pathology and to describe the anatomy. The first work concerns CT of the temporal bone and cochlear implant surgery in children with CHARGE association. This is a rare condition with multiple congenital abnormalities, sometimes lethal. Children with CHARGE have different combinations of disabilities, of which impairments of vision and hearing, as well as balance problems and facial palsy can lead to developmental delay. There have been few reports of radiological temporal bone changes and none of cochlear implant surgery for this group. The work includes a report of the findings on preoperative CT and at surgery, as well as postimplant results in two children. A review of the latest diagnostic criteria of CHARGE and the temporal bone changes found in international literature is also included. The conclusion was that certain combinations of temporal bone changes in CHARGE are, if not specific, at least extremely rare in other materials. CT can visualize these changes and be used as a diagnostic tool. This is important, since some of the associated disabilities are not so obvious from the start. Early treatment is vital for the child's development. This work also shows that cochlear implantation may help some of these often very isolated children to

  16. Aspects of temporal bone anatomy and pathology in conjunction with cochlear implant surgery

    International Nuclear Information System (INIS)

    Stjernholm, Christina

    2003-01-01

    Cochlear implantation is a treatment for patients with severe sensorineural hearing loss/deafness, who get no help from ordinary hearing aids. The cochlear implant is surgically placed under the skin near the ear and a very thin electrode array is introduced into the cochlea of the inner ear, where it stimulates the remaining nerve fibers. The operation is complicated; it is performed with the aid of a microscope, and involves drilling very close to vital vessels and important nerves. High resolution computed tomography (CT) of the temporal bone is a part of the preoperative evaluation preceding cochlear implantation. It is a method for visualizing the bony structures of the middle and inner ear - to diagnose pathology and to describe the anatomy. The first work concerns CT of the temporal bone and cochlear implant surgery in children with CHARGE association. This is a rare condition with multiple congenital abnormalities, sometimes lethal. Children with CHARGE have different combinations of disabilities, of which impairments of vision and hearing, as well as balance problems and facial palsy can lead to developmental delay. There have been few reports of radiological temporal bone changes and none of cochlear implant surgery for this group. The work includes a report of the findings on preoperative CT and at surgery, as well as postimplant results in two children. A review of the latest diagnostic criteria of CHARGE and the temporal bone changes found in international literature is also included. The conclusion was that certain combinations of temporal bone changes in CHARGE are, if not specific, at least extremely rare in other materials. CT can visualize these changes and be used as a diagnostic tool. This is important, since some of the associated disabilities are not so obvious from the start. Early treatment is vital for the child's development. This work also shows that cochlear implantation may help some of these often very isolated children to communicate

  17. Cochlear implantation in late-implanted adults with prelingual deafness.

    Science.gov (United States)

    Most, Tova; Shrem, Hadas; Duvdevani, Ilana

    2010-01-01

    The purpose of this study was to examine the effect of cochlear implantation (CI) on prelingually deafened participants who were implanted as adults. The effect of the CI was examined with regard to the following variables: communication, family, social skills, education, and work satisfaction with one's life, loneliness, and self-esteem. Thirty-eight adults participated. Four self-report questionnaires were used at 2 points in time: before and after CI. The research findings show significant differences in the reports of most variables before and after implantation. The participants felt better with regard to communication, social skills, education, and work and satisfaction with one's life after implantation in comparison to their feelings before implantation. Furthermore, they felt less lonely after implantation. However, there were no significant differences before and after implantation regarding their feelings within the family and regarding their self-esteem. The results demonstrated the need to evaluate the benefits resulting from the CI not only with traditional clinical measures but with additional measures as well. Furthermore, they demonstrated the benefit of the CI on the positive psychosociological implications of prelingually deafened adults. Copyright © 2010 Elsevier Inc. All rights reserved.

  18. The hearing benefit of cochlear implantation for individuals with unilateral hearing loss, but no tinnitus.

    Science.gov (United States)

    Skarzynski, Henryk; Lorens, Artur; Kruszynska, Marika; Obrycka, Anita; Pastuszak, Dorota; Skarzynski, Piotr Henryk

    2017-07-01

    Cochlear implants improve the hearing abilities of individuals with unilateral hearing loss and no tinnitus. The benefit is no different from that seen in patients with unilateral hearing loss and incapacitating tinnitus. To evaluate hearing outcomes after cochlear implantation in individuals with unilateral hearing loss and no tinnitus and compare them to those obtained in a similar group who had incapacitating tinnitus. Six cases who did not experience tinnitus before operation and 15 subjects with pre-operative tinnitus were evaluated with a structured interview, a monosyllabic word test under difficult listening situations, a sound localization test, and an APHAB (abbreviated profile of hearing aid benefit) questionnaire. All subjects used their cochlear implant more than 8 hours a day, 7 days a week. In 'no tinnitus' patients, mean benefit of cochlear implantation was 19% for quiet speech, 15% for speech in noise (with the same signal-to-noise ratio in the implanted and non-implanted ear), and 16% for a more favourable signal-to-noise ratio at the implanted ear. Sound localization error improved by an average of 19°. The global score of APHAB improved by 16%. The benefits across all evaluations did not differ significantly between the 'no tinnitus' and 'tinnitus' groups.

  19. Sirviendo a los estudiantes sordos que tienen Los implantes cocleares. Hoja de consejos de PEPNet (Serving Deaf Students Who Have Cochlear Implants. PEPNet Tipsheet)

    Science.gov (United States)

    Clark, Catherine

    2010-01-01

    This version of "Serving Deaf Students Who Have Cochlear Implants. PEPNet Tipsheet," written in Spanish, describes how cochlear implants (CIs) work. CIs are complex electronic devices surgically implanted under the skin behind the ear. These devices utilize electrodes placed in the inner ear (the cochlea) to stimulate the auditory nerve of…

  20. Self-esteem and social well-being of children with cochlear implant compared to normal-hearing children

    DEFF Research Database (Denmark)

    Percy-Smith, L.; Caye-Thomasen, P.; Gudman, M.

    2008-01-01

    Objective: The purpose of this study was to make a quantitative comparison of parameters of self-esteem and social well-being between children with cochlear implants and normal-hearing children. Material and methods: Data were obtained from 164 children with cochlear implant (CI) and 2169 normal......-hearing children (NH). Parental questionnaires, used in a national survey assessing the self-esteem and well-being of normal-hearing children, were applied to the cochlear implanted group, in order to allow direct comparisons. Results: The children in the CI group rated significantly higher on questions about well...... overall self-esteem or number of friends. The two groups of children scored similarly on being confident, independent, social, not worried and happy. Conclusion: Children with cochlear implant score equal to or better than their normal-hearing peers on matters of self-esteem and social well-being. (C...

  1. Hearing preservation cochlear implantation in children: The HEARRING Group consensus and practice guide.

    Science.gov (United States)

    Rajan, Gunesh; Tavora-Vieira, Dayse; Baumgartner, Wolf-Dieter; Godey, Benoit; Müller, Joachim; O'Driscoll, Martin; Skarzynski, Henryk; Skarzynski, Piotr; Usami, Shin-Ichi; Adunka, Oliver; Agrawal, Sumit; Bruce, Iain; De Bodt, Marc; Caversaccio, Marco; Pilsbury, Harold; Gavilán, Javier; Hagen, Rudolf; Hagr, Abdulrahman; Kameswaran, Mohan; Karltorp, Eva; Kompis, Martin; Kuzovkov, Vlad; Lassaletta, Luis; Yongxin, Li; Lorens, Artur; Manoj, Manikoth; Martin, Jane; Mertens, Griet; Mlynski, Robert; Parnes, Lorne; Pulibalathingal, Sasidharan; Radeloff, Andreas; Raine, Christopher H; Rajeswaran, Ranjith; Schmutzhard, Joachim; Sprinzl, Georg; Staecker, Hinrich; Stephan, Kurt; Sugarova, Serafima; Zernotti, Mario; Zorowka, Patrick; Van de Heyning, Paul

    2018-01-01

    To provide multidisciplinary cochlear implant teams with a current consensus statement to support hearing preservation cochlear implantation (HPCI) in children, including those children with symptomatic partial deafness (PD) where the intention is to use electric-acoustic stimulation (EAS). The main objectives are to provide guidelines on who is a candidate, how to assess these children and when to implant if Med-El Flex electrode arrays are chosen for implantation. The HEARRING group reviewed the current evidence and practice regarding the management of children to be considered for HPCI surgery emphasizing the assessment needed prior to implantation in order to demonstrate the benefits in these children over time. The consensus statement addresses following three key questions: (1) Should these children be treated? (2) How to identify these children? (3) How to manage these children? The HEARRING group concludes that irrespective of the degree of residual hearing present, the concepts of hearing and structure preservation should be applied in every child undergoing cochlear implantation and that HPCI is a safe and reliable treatment option. Early detection and multidisciplinary assessment are key to the identification of children with symptomatic PD, these children should undergo HPCI as early as possible.

  2. Environmental Sound Training in Cochlear Implant Users

    Science.gov (United States)

    Shafiro, Valeriy; Sheft, Stanley; Kuvadia, Sejal; Gygi, Brian

    2015-01-01

    Purpose: The study investigated the effect of a short computer-based environmental sound training regimen on the perception of environmental sounds and speech in experienced cochlear implant (CI) patients. Method: Fourteen CI patients with the average of 5 years of CI experience participated. The protocol consisted of 2 pretests, 1 week apart,…

  3. Hearing loss patterns after cochlear implantation via the round window in an animal model.

    Science.gov (United States)

    Attias, Joseph; Hod, Roy; Raveh, Eyal; Mizrachi, Aviram; Avraham, Karen B; Lenz, Danielle R; Nageris, Ben I

    2016-01-01

    The mechanism and the type of hearing loss induced by cochlear implants are mostly unknown. Therefore, this study evaluated the impact and type of hearing loss induced by each stage of cochlear implantation surgery in an animal model. Original basic research animal study. The study was conducted in a tertiary, university-affiliated medical center in accordance with the guidelines of the Institutional Animal Care and Use Committee. Cochlear implant electrode array was inserted via the round window membrane in 17 ears of 9 adult-size fat sand rats. In 7 ears of 5 additional animals round window incision only was performed, followed by patching with a small piece of periosteum (control). Hearing thresholds to air (AC) and bone conduction (BC), clicks, 1 kHz and 6 kHz tone bursts were measured by auditory brainstem evoked potential, before, during each stage of surgery and one week post-operatively. In addition, inner ear histology was performed. The degree of hearing loss increased significantly from baseline throughout the stages of cochlear implantation surgery and up to one week after (plosses were found for 1-kHz and 6-kHz frequencies. The hearing loss was not associated with significant changes in inner ear histology. Hearing loss following cochlear implantation in normal hearing animals is progressive and of mixed type, but mainly conductive. Changes in the inner-ear mechanism are most likely responsible for the conductive hearing loss. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Temporal and spectral contributions to musical instrument identification and discrimination among cochlear implant users

    Institute of Scientific and Technical Information of China (English)

    Sandra M. Prentiss; David R. Friedland; Tanner Fullmer; Alison Crane; Timothy Stoddard; Christina L. Runge

    2016-01-01

    Objective:To investigate the contributions of envelope and fine-structure to the perception of timbre by cochlear implant (CI) users as compared to normal hearing (NH) lis-teners. Methods: This was a prospective cohort comparison study. Normal hearing and cochlear implant patients were tested. Three experiments were performed in sound field using musical notes altered to affect the characteristic pitch of an instrument and the acoustic envelope. Experiment 1 assessed the ability to identify the instrument playing each note, while experi-ments 2 and 3 assessed the ability to discriminate the different stimuli. Results:Normal hearing subjects performed better than CI subjects in all instrument identifi-cation tasks, reaching statistical significance for 4 of 5 stimulus conditions. Within the CI pop-ulation, acoustic envelope modifications did not significantly affect instrument identification or discrimination. With envelope and pitch cues removed, fine structure discrimination perfor-mance was similar between normal hearing and CI users for the majority of conditions, but some specific instrument comparisons were significantly more challenging for CI users. Conclusions:Cochlear implant users perform significantly worse than normal hearing listeners on tasks of instrument identification. However, cochlear implant listeners can discriminate differences in envelope and some fine structure components of musical instrument sounds as well as normal hearing listeners. The results indicated that certain fine structure cues are important for cochlear implant users to make discrimination judgments, and therefore may affect interpretation toward associating with a specific instrument for identification.

  5. Educational, employment, and social participation of young adult graduates from the paediatric Southern Cochlear Implant Programme, New Zealand.

    Science.gov (United States)

    Goh, Terence; Bird, Philip; Pearson, John; Mustard, Jill

    2016-01-01

    The purpose of this study is to observe the education and vocational achievements and social participation of cochlear implant recipients as they graduate from a paediatric cochlear implant programme and identify any significant associations that might exist. This study identified 56 patients from the Southern Cochlear Implant Programme (SCIP) who received cochlear implants before the age of 19 (paediatric) and are now over the age of 19 (adult). A questionnaire investigated their education, employment, and identity with the hearing and deaf communities. Also included were the satisfaction with life scale and Hearing Participation Scale (HPS). Subjects ranged in age from 19 to 32. Twenty-six patients responded to the questionnaire, including one non-user. Twenty identified strongly or very strongly with the hearing community. There was weak evidence of a linear association between strong identity with the hearing community and a higher HPS score. No other statistically significant associations were detected. Interestingly, 12 out of 26 participants found employment through family. Positive outcome trends in education and employment were seen in this study although no statistical significance was achieved. There is a strong bias for those who use their cochlear implants regularly, and there are no data available for those who do not use their cochlear implants for comparison as only one non-user completed the survey, despite efforts to include this group. This study shows that there is perceived benefit in implantation for patients who use it regularly but further research is needed with a more diverse group of cochlear implant recipients.

  6. Modifying cochlear implant design: advantages of placing a return electrode in the modiolus.

    Science.gov (United States)

    Ho, Steven Y; Wiet, Richard J; Richter, Claus-Peter

    2004-07-01

    A modiolar return electrode significantly increases the current flow across spiral ganglion cells into the modiolus, and may decrease the cochlear implant's power requirements. Ideal cochlear implants should maximize current flow into the modiolus to stimulate auditory neurons. Previous efforts to facilitate current flow through the modiolus included the fabrication and use of precurved electrodes designed to "hug" the modiolus and silastic positioners designed to place the electrodes closer to the modiolus. In contrast to earlier efforts, this study explores the effects of return electrode placement on current distributions in the modiolus. The effects of return electrode positioning on current flow in the modiolus were studied in a Plexiglas model of the cochlea. Results of model measurements were confirmed by measurements in the modiolus of human temporal bones. The return electrode was placed either within the modiolus, or remotely, outside the temporal bone, simulating contemporary cochlear implant configurations using monopolar stimulation. Cochlear model results clearly show that modiolar current amplitudes can be influenced significantly by the location of the return electrode, being larger when placed into the modiolus. Temporal bone data show similar findings. Voltages recorded in the modiolus are, on average, 2.8 times higher with the return electrode in the modiolus compared with return electrode locations outside the temporal bone. Placing a cochlear implant's return electrode in the modiolus should significantly reduce its power consumption. Reducing power requirements should lead to improved efficiency, safer long-term use, and longer device life.

  7. Cochlear implantation in children and adults in Switzerland

    OpenAIRE

    Brand, Yves; Senn, Pascal; Kompis, Martin; Dillier, Norbert; Allum, John H. J.

    2014-01-01

    The cochlear implant (CI) is one of the most successful neural prostheses developed to date. It offers artificial hearing to individuals with profound sensorineural hearing loss and with insufficient benefit from conventional hearing aids. The first implants available some 30 years ago provided a limited sensation of sound. The benefit for users of these early systems was mostly a facilitation of lip-reading based communication rather than an understanding of speech. Considerable progress has...

  8. [Morphologic feature and cochlear implant surgical approach for cochlear modiolus deficiency].

    Science.gov (United States)

    Zhang, Daoxing

    2014-09-01

    To review the classification of cochlear modiolus deficiency and decision on surgical approach for above case,in order to provide mastery for cochlear implant (CI) indication. Basing on temporal bone HRCT pre-operation, CI subjects with modiolus deficiency were defined as following groups: (1) deficiency caused by cochlear dysplasia (Mondini malformation); (2) deficiency caused by dysplasia of cochlear and vestibule (Common cavity malformation); (3) deficiency caused by absence of internal acoustic meatus fundus (IP-III malformation). Three types of surgical approach were utilized: type I, electrode array was introduced through facial recess, enlarged the round window, type II, opened the surface of chchlea, electrode array was introduced through facial recess, fenestration on posterior promontory and then inserted around lateral wall of inner-cochlear cavity. type III, electrode array was introduce through fenestration of lateral semicircular canal and then placed close to the bony wall of common cavity. One hundred and sixty-six cochlear modiolus deficiency cases were identified into 3 groups as following: 135 Mondini malformation cases into group a, 18 common cavity malformation cases into group b, and 13 IP-III malformation cases into group c. Surgical approach: type I were used in 136 cases (123 Mondini cases and 13 IP-III cases), while approach type II in 12 cases (12 Mondini cases), and approach type III in 18 cases (18 common cavity cases). Income post-operation of CI: For group a (Mondini malformation), post-activation mean hearing threshold in sound field was 65 dB, speech recognition score is 95% (single finals test) and 25% (signal initials test), while it was 80 dB, 60% and 0 for group b (Conmon cavity malformation), and it was 55 dB, 100% and 45% for group c (IP-III malformation). The income of speech recognition score for cochlear modiolus deficiency was relatively poor, group b was worst and group c was best, while group a moderate.

  9. Effect of gender on the hearing performance of adult cochlear implant patients.

    Science.gov (United States)

    Lenarz, Minoo; Sönmez, Hasibe; Joseph, Gert; Büchner, Andreas; Lenarz, Thomas

    2012-05-01

    To evaluate the role of gender on the hearing performance of postlingually deafened adult patients with cochlear implants. Individual retrospective cohort study. There were 638 postlingually deafened adults (280 men and 358 women) selected for a retrospective evaluation of their hearing performance with cochlear implants. Both genders underwent the same surgical and rehabilitative procedures and benefited from the latest technological advances available. There was no significant difference in the age, duration of deafness, and preoperative hearing performance between the genders. The test battery was composed of the Freiburger Monosyllabic Test, Speech Tracking, and the Hochmair-Schulz-Moser (HSM) sentence test in quiet and in 10-dB noise. The results of 5 years of follow-up are presented here. Genders showed a similar performance in Freiburger Monosyllabic Test and Speech Tracking Test. However, in the HSM test in noise, men performed slightly better than women in all of the follow-up sessions, which was statistically significant at 2 and 4 years after implantation. Although normal-hearing women use more predictive cognitive strategies in speech comprehension and are supposed to have a more efficient declarative memory system, this may not necessarily lead to a better adaptation to the altered auditory information delivered by a cochlear implant. Our study showed that in more complex listening situations such as speech tests in noise, men tend to perform slightly better than women. Gender may have an influence on the hearing performance of postlingually deafened adults with cochlear implants. Copyright © 2012 The American Laryngological, Rhinological, and Otological Society, Inc.

  10. The Effect of Microphone Placement on Interaural Level Differences and Sound Localization Across the Horizontal Plane in Bilateral Cochlear Implant Users.

    Science.gov (United States)

    Jones, Heath G; Kan, Alan; Litovsky, Ruth Y

    2016-01-01

    This study examined the effect of microphone placement on the interaural level differences (ILDs) available to bilateral cochlear implant (BiCI) users, and the subsequent effects on horizontal-plane sound localization. Virtual acoustic stimuli for sound localization testing were created individually for eight BiCI users by making acoustic transfer function measurements for microphones placed in the ear (ITE), behind the ear (BTE), and on the shoulders (SHD). The ILDs across source locations were calculated for each placement to analyze their effect on sound localization performance. Sound localization was tested using a repeated-measures, within-participant design for the three microphone placements. The ITE microphone placement provided significantly larger ILDs compared to BTE and SHD placements, which correlated with overall localization errors. However, differences in localization errors across the microphone conditions were small. The BTE microphones worn by many BiCI users in everyday life do not capture the full range of acoustic ILDs available, and also reduce the change in cue magnitudes for sound sources across the horizontal plane. Acute testing with an ITE placement reduced sound localization errors along the horizontal plane compared to the other placements in some patients. Larger improvements may be observed if patients had more experience with the new ILD cues provided by an ITE placement.

  11. Cochlear Implant Spatial Selectivity with Monopolar, Bipolar and Tripolar Stimulation

    Science.gov (United States)

    Zhu, Ziyan; Tang, Qing; Zeng, Fan-Gang; Guan, Tian; Ye, Datian

    2011-01-01

    Sharp spatial selectivity is critical to auditory performance, particularly in pitch related tasks. Most contemporary cochlear implants have employed monopolar stimulation that produces broad electric fields, which presumably contribute to poor pitch and pitch-related performance by implant users. Bipolar or tripolar stimulation can generate focused electric fields but requires higher current to reach threshold and, more interestingly, has not produced any apparent improvement in cochlear implant performance. The present study addressed this dilemma by measuring psychophysical and physiological spatial selectivity with both broad and focused stimulations in the same cohort of subjects. Different current levels were adjusted by systematically measuring loudness growth for each stimulus, each stimulation mode, and in each subject. Both psychophysical and physiological measures showed that, although focused stimulation produced significantly sharper spatial tuning than monopolar stimulation, it could shift the tuning position or even split the tuning tips. The altered tuning with focused stimulation is interpreted as a result of poor electrode-to-neuron interface in the cochlea, and is suggested to be mainly responsible for the lack of consistent improvement in implant performance. A linear model could satisfactorily quantify the psychophysical and physiological data and derive the tuning width. Significant correlation was found between the individual physiological and psychophysical tuning widths, and the correlation was improved by log-linearly transforming the physiological data to predict the psychophysical data. Because the physiological measure took only one-tenth of the time of the psychophysical measure, the present model is of high clinical significance in terms of predicting and improving cochlear implant performance. PMID:22138630

  12. Cochlear Implantation in Patients with Neurofibromatosis Type 2 and Patients with Vestibular Schwannoma in the Only Hearing Ear

    Directory of Open Access Journals (Sweden)

    Erika Celis-Aguilar

    2012-01-01

    Full Text Available Cochlear implants are a new surgical option in the hearing rehabilitation of patients with neurofibromatosis type 2 (NF2 and patients with vestibular schwannoma (VS in the only hearing ear. Auditory brainstem implant (ABI has been the standard surgical treatment for these patients. We performed a literature review of patients with NF2 and patients with VS in the only hearing ear. Cochlear implantation (CI provided some auditory benefit in all patients. Preservation of cochlear nerve integrity is crucial after VS resection. Results ranged from environmental sound awareness to excellent benefit with telephone use. Promontory stimulation is recommended although not crucial. MRI can be performed safely in cochlear implanted patients.

  13. A Rare Complication of Cochlear Implantation After Magnetic Resonance Imaging: Reversion of the Magnet.

    Science.gov (United States)

    Öztürk, Erkan; Doruk, Can; Orhan, Kadir Serkan; Çelik, Mehmet; Polat, Beldan; Güldiken, Yahya

    2017-06-01

    Cochlear implants are mechanical devices used for patients with severe sensory-neural hearing loss, which has an inner magnet. It is proven that 1.5 Tesla magnetic resonance imaging (MRI) scanners are safe to use in patients with cochlear implant. In our patient, the authors aim to introduce a rare complication caused after a 1.5 Tesla MRI scanning and the management of this situation; the reversion of the magnet of the implant without displacement and significance of surgery in management.

  14. Breaking the sound barrier: exploring parents' decision-making process of cochlear implants for their children.

    Science.gov (United States)

    Chang, Pamara F

    2017-08-01

    To understand the dynamic experiences of parents undergoing the decision-making process regarding cochlear implants for their child(ren). Thirty-three parents of d/Deaf children participated in semi-structured interviews. Interviews were digitally recorded, transcribed, and coded using iterative and thematic coding. The results from this study reveal four salient topics related to parents' decision-making process regarding cochlear implantation: 1) factors parents considered when making the decision to get the cochlear implant for their child (e.g., desire to acculturate child into one community), 2) the extent to which parents' communities influence their decision-making (e.g., norms), 3) information sources parents seek and value when decision-making (e.g., parents value other parent's experiences the most compared to medical or online sources), and 4) personal experiences with stigma affecting their decision to not get the cochlear implant for their child. This study provides insights into values and perspectives that can be utilized to improve informed decision-making, when making risky medical decisions with long-term implications. With thorough information provisions, delineation of addressing parents' concerns and encompassing all aspects of the decision (i.e., medical, social and cultural), health professional teams could reduce the uncertainty and anxiety for parents in this decision-making process for cochlear implantation. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Mismatch Negativity Based Neurofeedback for Cochlear Implant Users

    NARCIS (Netherlands)

    Luckmann, Annika; Başkent, Deniz; Jolij, Jacob

    2015-01-01

    Cochlear implant (CI) users experience great difficulty when it comes to pitch discrimination. This leads to problems during daily interactions, due to poor speech perception, but also a very low pleasure ratings for music. Improving pitch perception and discrimination in CI users would improve

  16. Comparison of two approaches to the surgical management of cochlear implantation

    NARCIS (Netherlands)

    Postelmans, Job T. F.; Grolman, Wilko; Tange, Rinze A.; Stokroos, Robert J.

    2009-01-01

    OBJECTIVES/HYPOTHESIS: Our study was designed to compare two surgical approaches that are currently employed in cochlear implantation. METHODS: There were 315 patients who were divided into two groups according to the surgical technique used for implantation. The suprameatal approach (SMA) was

  17. Presbycusis occurs after cochlear implantation also: a retrospective study of pure tone thresholds over time.

    Science.gov (United States)

    Trosman, Samuel; Matusik, Deanna Kattah; Ferro, Lia; Gao, Weihua; Saadia-Redleaf, Miriam

    2012-12-01

    To assess aided soundfield pure tone thresholds after cochlear implantation in adults over time. Retrospective case review. Academic tertiary care center. Seventy-seven severe-to-profoundly deafened adults implanted with one of 5 different internal devices. Cochlear implantation. Outcome measures were cochlear implant aided soundfield pure tone thresholds at 250, 500, 1,000, 2,000, 4,000, and 6,000 Hz. For the 77 adult patients in the study, pure tone aided thresholds deteriorated over time at 500, 1,000, 2,000, 4,000, and 6,000 Hz at rates ranging from 0.54 to 0.86 dB per year with the implant (p presbycusis, this deterioration is most prominent at the highest frequencies; however, the incidence and rate of deterioration is higher than that seen in presbycusis. These physiologic changes are not indicative of device failure and do not mean that performance measures will necessarily deteriorate.

  18. Intraoperative Cochlear Implant Device Testing Utilizing an Automated Remote System: A Prospective Pilot Study.

    Science.gov (United States)

    Lohmann, Amanda R; Carlson, Matthew L; Sladen, Douglas P

    2018-03-01

    Intraoperative cochlear implant device testing provides valuable information regarding device integrity, electrode position, and may assist with determining initial stimulation settings. Manual intraoperative device testing during cochlear implantation requires the time and expertise of a trained audiologist. The purpose of the current study is to investigate the feasibility of using automated remote intraoperative cochlear implant reverse telemetry testing as an alternative to standard testing. Prospective pilot study evaluating intraoperative remote automated impedance and Automatic Neural Response Telemetry (AutoNRT) testing in 34 consecutive cochlear implant surgeries using the Intraoperative Remote Assistant (Cochlear Nucleus CR120). In all cases, remote intraoperative device testing was performed by trained operating room staff. A comparison was made to the "gold standard" of manual testing by an experienced cochlear implant audiologist. Electrode position and absence of tip fold-over was confirmed using plain film x-ray. Automated remote reverse telemetry testing was successfully completed in all patients. Intraoperative x-ray demonstrated normal electrode position without tip fold-over. Average impedance values were significantly higher using standard testing versus CR120 remote testing (standard mean 10.7 kΩ, SD 1.2 vs. CR120 mean 7.5 kΩ, SD 0.7, p automated testing with regard to the presence of open or short circuits along the array. There were, however, two cases in which standard testing identified an open circuit, when CR120 testing showed the circuit to be closed. Neural responses were successfully obtained in all patients using both systems. There was no difference in basal electrode responses (standard mean 195.0 μV, SD 14.10 vs. CR120 194.5 μV, SD 14.23; p = 0.7814); however, more favorable (lower μV amplitude) results were obtained with the remote automated system in the apical 10 electrodes (standard 185.4 μV, SD 11.69 vs. CR

  19. Reading comprehension of deaf children with cochlear implants

    NARCIS (Netherlands)

    Vermeulen, A.M.; Bon, W.H.J. van; Schreuder, R.; Knoors, H.E.T.; Snik, A.F.M.

    2007-01-01

    The reading comprehension and visual word recognition in 50 deaf children and adolescents with at least 3 years of cochlear implant (0) use were evaluated. Their skills were contrasted with reference data of 500 deaf children without CIs. The reading comprehension level in children with CIs was

  20. Three challenges for future research on cochlear implants

    Directory of Open Access Journals (Sweden)

    David B. Pisoni

    2017-12-01

    Full Text Available Cochlear implants (CIs often work very well for many children and adults with profound sensorineural (SNHL hearing loss. Unfortunately, while many CI patients display substantial benefits in recognizing speech and understanding spoken language following cochlear implantation, a large number of patients achieve poor outcomes. Understanding and explaining the reasons for poor outcomes following implantation is a very challenging research problem that has received little attention despite the pressing clinical significance. In this paper, we discuss three challenges for future research on CIs. First, we consider the issue of individual differences and variability in outcomes following implantation. At the present time, we still do not have a complete and satisfactory account of the causal underlying factors that are responsible for the enormous individual differences and variability in outcomes. Second, we discuss issues related to the lack of preimplant predictors of outcomes. Very little prospective research has been carried out on the development of preimplant predictors that can be used to reliably identify CI candidates who may be at high risk for a poor outcome following implantation. Other than conventional demographics and hearing history, there are no prognostic tools available to predict speech recognition outcomes after implantation. Finally, we discuss the third challenge — what to do with a CI-user who has a poor outcome. We suggest that new research efforts need to be devoted to studying this neglected clinical population in greater depth to find out why they are doing poorly with their CI and what novel interventions and treatments can be developed to improve their speech recognition outcomes. Using these three challenges as objectives for future research on CIs, we suggest that the field needs to adopt a new narrative grounded in theory and methods from Cognitive Hearing Science and information processing theory. Without knowing

  1. Safety of Monopolar Electrocautery in Patients With Cochlear Implants.

    Science.gov (United States)

    Tien, Duc A; Woodson, Erika A; Anne, Samantha

    2016-09-01

    The outcomes of 2 patients with cochlear implants (CIs) who underwent adenotonsillectomy (AT) with inadvertent use of monopolar cautery are presented. The safety data regarding monopolar cautery use in CI recipients is also reviewed. This is a retrospective case series of 2 CI recipients that underwent AT with monopolar cautery and literature review of electrocautery safety in the setting of CI. Two patients with CIs underwent AT with use of monopolar cautery inadvertently by surgeons that do not routinely perform cochlear implants as part of his or her clinical practice. Patient 1 was a 9-year-old female who had AT for obstructive sleep apnea (OSA) after undergoing unilateral CI for profound congenital sensorineural hearing loss (SNHL) 8 years ago. Patient 2 was a 7-year-old female who underwent AT for OSA 4 months after undergoing unilateral CI for congenital SNHL. Both patients had no immediate signs of complications with their CI use postoperatively. Both patients demonstrated unchanged postoperative neural response telemetry and behavioral audiometric testing. Patient 1 continues to have no CI-related complications 3.5 years after the procedure. Patient 2 has been followed for at least 3 months by audiometric testing and 10 months by otolaryngologist with no CI-related complications. Although animal and cadaveric studies suggest that monopolar cautery may be safely used in patients with cochlear implants, there have been no in vivo human studies that have evaluated the risk to the patient or implant. This is a report of a small, unintended experience with 2 patients, both of whom exhibit no complications or changes to CI function thus far. © The Author(s) 2016.

  2. Parental mode of communication is essential for speech and language outcomes in cochlear implanted children

    DEFF Research Database (Denmark)

    Percy-Smith, Lone; Cayé-Thomasen, Per; Breinegaard, Nina

    2010-01-01

    The present study demonstrates a very strong effect of the parental communication mode on the auditory capabilities and speech/language outcome for cochlear implanted children. The children exposed to spoken language had higher odds of scoring high in all tests applied and the findings suggest...... a very clear benefit of spoken language communication with a cochlear implanted child....

  3. Causes of hearing impairment in the Norwegian paediatric cochlear implant program.

    Science.gov (United States)

    Siem, Geir; Fagerheim, Toril; Jonsrud, Christoffer; Laurent, Claude; Teig, Erik; Harris, Sten; Leren, Trond P; Früh, Andreas; Heimdal, Ketil

    2010-08-01

    Severe to profound hearing impairment (HI) is estimated to affect around 1/2000 young children. Advances in genetics have made it possible to identify several genes related to HI. This information can cast light upon prognostic factors regarding the outcome in cochlear implantation, and provide information both for scientific and genetic counselling purposes. From 1992 to 2005, 273 children from 254 families (probands) were offered cochlear implants in Norway. An evaluation of the causes of HI, especially regarding the genes GJB2, GJB6, SLC26A4, KCNQ1, KCNE1, and the mutation A1555G in mitochondrial DNA was performed in 85% of the families. The number of probands with unknown cause of HI was thus reduced from 120 to 68 (43% reduction). Ninety-eight (46%) of the probands had an identified genetic etiology of their HI. A relatively high prevalence of Jervell and Lange-Nielsen syndrome was found. The main causes of severe and profound HI were similar to those found in other European countries. GJB2 mutations are a common cause of prelingual HI in Norwegian cochlear implanted children.

  4. Temporal stability of music perception and appraisal scores of adult cochlear implant recipients.

    Science.gov (United States)

    Gfeller, Kate; Jiang, Dingfeng; Oleson, Jacob J; Driscoll, Virginia; Knutson, John F

    2010-01-01

    An extensive body of literature indicates that cochlear implants (CIs) are effective in supporting speech perception of persons with severe to profound hearing losses who do not benefit to any great extent from conventional hearing aids. Adult CI recipients tend to show significant improvement in speech perception within 3 mo following implantation as a result of mere experience. Furthermore, CI recipients continue to show modest improvement as long as 5yr postimplantation. In contrast, data taken from single testing protocols of music perception and appraisal indicate that CIs are less than ideal in transmitting important structural features of music, such as pitch, melody, and timbre. However, there is presently little information documenting changes in music perception or appraisal over extended time as a result of mere experience. This study examined two basic questions: (1) Do adult CI recipients show significant improvement in perceptual acuity or appraisal of specific music listening tasks when tested in two consecutive years? (2) If there are tasks for which CI recipients show significant improvement with time, are there particular demographic variables that predict those CI recipients most likely to show improvement with extended CI use? A longitudinal cohort study. Implant recipients return annually for visits to the clinic. The study included 209 adult cochlear implant recipients with at least 9 mo implant experience before their first year measurement. Outcomes were measured on the patient's annual visit in two consecutive years. Paired t-tests were used to test for significant improvement from one year to the next. Those variables demonstrating significant improvement were subjected to regression analyses performed to detect the demographic variables useful in predicting said improvement. There were no significant differences in music perception outcomes as a function of type of device or processing strategy used. Only familiar melody recognition (FMR

  5. Cochlear-implant spatial selectivity with monopolar, bipolar and tripolar stimulation.

    Science.gov (United States)

    Zhu, Ziyan; Tang, Qing; Zeng, Fan-Gang; Guan, Tian; Ye, Datian

    2012-01-01

    Sharp spatial selectivity is critical to auditory performance, particularly in pitch-related tasks. Most contemporary cochlear implants have employed monopolar stimulation that produces broad electric fields, which presumably contribute to poor pitch and pitch-related performance by implant users. Bipolar or tripolar stimulation can generate focused electric fields but requires higher current to reach threshold and, more interestingly, has not produced any apparent improvement in cochlear-implant performance. The present study addressed this dilemma by measuring psychophysical and physiological spatial selectivity with both broad and focused stimulations in the same cohort of subjects. Different current levels were adjusted by systematically measuring loudness growth for each stimulus, each stimulation mode, and in each subject. Both psychophysical and physiological measures showed that, although focused stimulation produced significantly sharper spatial tuning than monopolar stimulation, it could shift the tuning position or even split the tuning tips. The altered tuning with focused stimulation is interpreted as a result of poor electrode-to-neuron interface in the cochlea, and is suggested to be mainly responsible for the lack of consistent improvement in implant performance. A linear model could satisfactorily quantify the psychophysical and physiological data and derive the tuning width. Significant correlation was found between the individual physiological and psychophysical tuning widths, and the correlation was improved by log-linearly transforming the physiological data to predict the psychophysical data. Because the physiological measure took only one-tenth of the time of the psychophysical measure, the present model is of high clinical significance in terms of predicting and improving cochlear-implant performance. Copyright © 2011 Elsevier B.V. All rights reserved.

  6. Strategies for Working with Children with Cochlear Implants

    Science.gov (United States)

    Schraer-Joiner, Lyn; Prause-Weber, Manuela

    2009-01-01

    According to the National Institute on Deafness and Other Communication Disorders, 23,000 individuals in the United States, including 10,000 children, have a cochlear implant. This biomedical electronic device has been a breakthrough in the auditory rehabilitation of individuals diagnosed with severe or profound sensorineural hearing losses who…

  7. Motor Development of Deaf Children with and without Cochlear Implants

    Science.gov (United States)

    Gheysen, Freja; Loots, Gerrit; Van Waelvelde, Hilde

    2008-01-01

    The purpose of this study was to investigate the impact of a cochlear implant (CI) on the motor development of deaf children. The study involved 36 mainstreamed deaf children (15 boys, 21 girls; 4- to 12-years old) without any developmental problems. Of these children, 20 had been implanted. Forty-three hearing children constituted a comparison…

  8. Audiophonological results after cochlear implantation in 40 congenitally deaf patients: preliminary results.

    Science.gov (United States)

    Loundon, N; Busquet, D; Roger, G; Moatti, L; Garabedian, E N

    2000-11-30

    The aim of this study is to evaluate the prognostic factors of audiophonological results in cochlear implant in congenitally deaf patients. Between 1991 and 1996. 40 congenitally deaf children underwent cochlear implantation in our department, at an average age of 7 years (median: 5 years). The results of speech therapy were evaluated with a mean follow-up of 2 years and were classified according to four criteria: perception of sound, speech perception, speech production and the level of oral language. For each criterion, a score was established ranging from zero to four. These scores were weighted according to age such that the results before and after implantation only reflected the changes related to the implantation. The prognostic factors for good results were: a good level of oral communication before implantation, residual hearing, progressive deafness and implantation at a young age. On the other hand, poor prognostic factors were: the presence of behavioral disorders and poor communication skills prior to implantation. Overall, the major prognostic factor for a good outcome appeared to be the preoperative level of oral language, even if this was rudimentary.

  9. An evaluation of preservation of residual hearing using the suprameatal approach for cochlear implantation: can this implantation technique be used for preservation of residual hearing?

    NARCIS (Netherlands)

    Postelmans, Job T. F.; van Spronsen, Erik; Grolman, Wilko; Stokroos, Robert J.; Tange, Rinze A.; Maré, Marcel J.; Dreschler, Wouter A.

    2011-01-01

    The preservation of residual hearing has become a high priority in cochlear implant surgery. This study was designed to substantiate whether conservation of residual hearing can be preserved after cochlear implantation using the suprameatal approach. Retrospective chart review. Retrospective chart

  10. Biomedical engineering principles of modern cochlear implants and recent surgical innovations.

    Science.gov (United States)

    Eshraghi, Adrien A; Gupta, Chhavi; Ozdamar, Ozcan; Balkany, Thomas J; Truy, Eric; Nazarian, Ronen

    2012-11-01

    This review covers the most recent clinical and surgical advances made in the development and application of cochlear implants (CIs). In recent years, dramatic progress has been made in both clinical and basic science aspect of cochlear implantation. Today's modern CI uses multi-channel electrodes with highly miniaturized powerful digital processing chips. This review article describes the function of various components of the modern multi-channel CIs. A selection of the most recent clinical and surgical innovations is presented. This includes the preliminary results with electro-acoustic stimulation or hybrid devices and ongoing basic science research that is focused on the preservation of residual hearing post-implantation. The result of an original device that uses a binaural stimulation mode with a single implanted receiver/stimulator is also presented. The benefit and surgical design of a temporalis pocket technique for the implant's receiver stimulator is discussed. Advances in biomedical engineering and surgical innovations that lead to an increasingly favorable clinical outcome and to an expansion of the indication of CI surgery are presented and discussed. Copyright © 2012 Wiley Periodicals, Inc.

  11. Auditory maturation in premature infants: a potential pitfall for early cochlear implantation.

    Science.gov (United States)

    Hof, Janny R; Stokroos, Robert J; Wix, Eduard; Chenault, Mickey; Gelders, Els; Brokx, Jan

    2013-08-01

    To describe spontaneous hearing improvement in the first years of life of a number of preterm neonates relative to cochlear implant candidacy. Retrospective case study. Hearing levels of 14 preterm neonates (mean gestational age at birth = 29 weeks) referred after newborn hearing screening were evaluated. Initial hearing thresholds ranged from 40 to 105 dBHL (mean = 85 dBHL). Hearing level improved to normal levels for four neonates and to moderate levels for five, whereas for five neonates, no improvement in hearing thresholds was observed and cochlear implantation was recommended. Three of the four neonates in whom the hearing improved to normal levels were born prior to 28 weeks gestational age. Hearing improvement was mainly observed prior to a gestational age of 80 weeks. Delayed maturation of an immature auditory pathway might be an important reason for referral after newborn hearing screening in premature infants. Caution is advised regarding early cochlear implantation in preterm born infants. Audiological follow-ups until at least 80 weeks gestational age are therefore recommended. © 2013 The American Laryngological, Rhinological and Otological Society, Inc.

  12. Clinical evaluation of music perception, appraisal and experience in cochlear implant users.

    Science.gov (United States)

    Drennan, Ward R; Oleson, Jacob J; Gfeller, Kate; Crosson, Jillian; Driscoll, Virginia D; Won, Jong Ho; Anderson, Elizabeth S; Rubinstein, Jay T

    2015-02-01

    The objectives were to evaluate the relationships among music perception, appraisal, and experience in cochlear implant users in multiple clinical settings and to examine the viability of two assessments designed for clinical use. Background questionnaires (IMBQ) were administered by audiologists in 14 clinics in the United States and Canada. The CAMP included tests of pitch-direction discrimination, and melody and timbre recognition. The IMBQ queried users on prior musical involvement, music listening habits pre and post implant, and music appraisals. One-hundred forty-five users of Advanced Bionics and Cochlear Ltd cochlear implants. Performance on pitch direction discrimination, melody recognition, and timbre recognition tests were consistent with previous studies with smaller cohorts, as well as with more extensive protocols conducted in other centers. Relationships between perceptual accuracy and music enjoyment were weak, suggesting that perception and appraisal are relatively independent for CI users. Perceptual abilities as measured by the CAMP had little to no relationship with music appraisals and little relationship with musical experience. The CAMP and IMBQ are feasible for routine clinical use, providing results consistent with previous thorough laboratory-based investigations.

  13. The long-term concerns post cochlear implantation as experienced ...

    African Journals Online (AJOL)

    quality of life of families with children who have a hearing loss or who are fitted with cochlear implants. .... term going into the work force with a severe disability will he be .... balance between professional caution and urgency of treatment.

  14. Intra- and intersubject comparison of cochlear implant systems using the Esprit and the Tempo+ behind-the-ear speech processor.

    Science.gov (United States)

    Kompis, Martin; Jenk, Martin; Vischer, Mattheus W; Seifert, Eberhard; Häusler, Rudolf

    2002-12-01

    A patient with bilateral profound deafness was implanted with a Nucleus CI24M cochlear implant (CI) and used an Esprit behind-the-ear (BTE) speech processor. Thirteen months later, the implant had to be removed because of a cholesteatoma. As the same electrode could not be reinserted, a Medel combi40s CI was implanted in the same ear, and the patient used a Tempo+ BTE processor. After 1 year of use of the Combi40s/Tempo+ system, speech recognition was better and was rated better subjectively than with the CI24M/Esprit system. Speech recognition and subjective ratings were also assessed for two matched groups of nine CI users each, using either an Esprit or a Tempo+ processor. On average, speech recognition scores were higher for the group of Tempo+ users, but the difference was not statistically significant. Users of the Esprit processors rated their device higher in terms of cosmetic appearance and comfort of wearing.

  15. [Effect of rehabilitation for prelingual deaf children who use cochlear implants in conjunction with hearing aids in the opposite ears].

    Science.gov (United States)

    Tian, Yanjing; Zhou, Huifang; Zhang, Jing; Yang, Dong; Xu, Yi; Guo, Yuxi

    2012-10-01

    To compare the effect of rehabilitation of prelingual deaf children who used a cochlear implant (CI) in one ear and a hearing aids in the opposite ear while the hearing level of the opposite ears are different. Hearing ability, language ability and learning ability was included in the content. The aim of this research is to investigate better style of rehabilitation, and to offer the best help to the prelingual deaf children. Accord ing to the hearing level of the ear opposite to the one wearing a cochlear implant and whether the opposite ear wear a hearing aid or not, 30 prelingual deaf children were divided into three groups, including cochlear implant with opposite severe hearing loss and hearing aid ear (CI+SHA), cochlear implant with opposite profound hearing loss and hearing aid ear (CI+PHA), cochlear implant only (CI). The effect of rehabilitation was assessed in six different times (3,6,9,12,15 and 18 months after the cochlear implants and hearing aids began to work). The longer time the rehabilitation spends, the better the hearing ability,language ability and the learning ability were. The hearing ability of CI+SHA was better than those of CI+PHA (Pdeaf children should take much more time on rehabilitation. The effect of rehabilitation for prelingual deaf children who used cochlear implant in one ear and hearing aid in the other depend on the residual hearing level of the other ear. If a prelingual deaf children still has any residual hearing level in the ear opposite to the cochlear implant ear, it is better for him/her to wear a hearing aid in the ear.

  16. Comparison of phonological awareness between children with cochlear implants and children with hearing aids

    Directory of Open Access Journals (Sweden)

    Farzad Weisi

    2013-02-01

    Full Text Available Introduction: Advanced phonological skills are important for the acquisition of reading skills. Children with hearing impairment have reading skills are weaker than others because of auditory inputs and due to the defect in phonological skills. The use of hearing aids and cochlear implants help to collect information on people who are hard of hearing.Material and Methods: This descriptive - analytic study was done on 12 children with cochlear implant and 12 children with hearing aids that was selected from second grades students of Tehran primary schools. Children's phonological performance was assessed by phonological subtests of Nama reading test and the data were analyzed using SPSS 16.Results: The results showed that the means of scores of children with cochlear implants in Rhyme task were significantly greater than the children with hearing aids (P=0.034. But in means of scores of Phone deletion and Nonword reading tasks were not significant different between two groups (P=0.919, P=0.670.Discussion: Cochlear implant with accessibility auditory inputs can facilitated the acquisition of phonological awareness skills in hearing loss children. But whereas the other language inputs such as sight and touch input helped to developing these skills, children with hearing aids too also can acquisition these skills.

  17. Playing Music May Improve the Gait Pattern in Patients with Bilateral Caloric Areflexia Wearing a Cochlear Implant: Results from a Pilot Study

    Directory of Open Access Journals (Sweden)

    Ann Hallemans

    2017-08-01

    Full Text Available HypothesisAuditory information through an active cochlear implant (CI influences gait parameters in adults with bilateral caloric areflexia and profound sensorineural hearing loss.BackgroundPatients with bilateral caloric areflexia suffer from imbalance, resulting in an increased risk of falling. In case of simultaneous deafness, the lack of auditory feedback results in less awareness of the auditory scene. This combination might produce significant challenges while walking and navigating. Auditory cues can be restored to some extent with a CI. Electrical stimulation through a CI can also produce a vestibulocollic reflex through current spread, which can be measured as cervical vestibular-evoked myogenic potentials.MethodsAdults (seven males, one female, mean age 61 ± 14 years, wearing a CI to treat profound sensorineural hearing loss and presenting with bilateral caloric areflexia walked barefoot, over ground, at self-selected speed in three different conditions: with CI turned on, while listening to music and with CI turned off. Spatiotemporal and kinematic parameters of gait were calculated using the conventional gait model.ResultsRemoving auditory feedback by turning off the CI decreased stride time (mean difference 0.03 ± 0.15 s and slightly increased stride length (mean difference 0.5 ± 1.2 cm compared to the control condition with the CI on. Walking while playing music positively affected gait compared to walking with the CI on but without auditory feedback. By increasing the motion of the pelvis (mean difference 1.3° ± 0.4°, the knee (mean difference 3.9° ± 0.8° and the ankle (mean difference 2.2° ± 0.2°, stride length increased (7.8 ± 1.2 cm, while stride time decreased (0.059 ± 0.016 s.ConclusionAlthough a practice effect cannot be completely ruled out, this pilot study suggests that playing music while wearing an active CI may improve gait in patients with bilateral otovestibular

  18. Trends in Intraoperative Testing During Cochlear Implantation.

    Science.gov (United States)

    Page, Joshua Cody; Cox, Matthew D; Hollowoa, Blake; Bonilla-Velez, Juliana; Trinidade, Aaron; Dornhoffer, John L

    2018-03-01

    No consensus guidelines exist regarding intraoperative testing during cochlear implantation and wide variation in practice habits exists. The objective of this observational study was to survey otologists/neurotologists to understand practice habits and overall opinion of usefulness of intraoperative testing. Cross-sectional survey. A web-based survey was sent to 194 practicing Otologists/Neurotologists. Questions included practice setting and experience, habits with respect to electrodes used, intraoperative testing modalities used, overall opinion of intraoperative testing, and practice habits in various scenarios. Thirty-nine of 194 (20%) completed the survey. For routine patients, ECAPs and EIs were most commonly used together (38%) while 33% do not perform testing at all. Eighty-nine percent note that testing "rarely" or "never" changes management. Fifty-one percent marked the most important reason for testing is the reassurance provided to the family and/or the surgeon. Intraoperative testing habits and opinions regarding testing during cochlear implantation vary widely among otologic surgeons. The majority of surgeons use testing but many think there is minimal benefit and that surgical decision-making is rarely impacted. The importance of testing may change as electrodes continue to evolve.

  19. Use of a gentamicin-impregnated collagen sheet (Collatamp(®)) in the management of major soft tissue complications in pediatric cochlear implants.

    Science.gov (United States)

    Benito-González, Fernando; Benito, Jose; Sánchez, Luis Alberto Guardado; Estevez Alonso, Santiago; Muñoz Herrera, Angel; Batuecas-Caletrio, Angel

    2014-09-01

    The objective was to report the effectiveness of salvage treatment in soft tissue infection around cochlear implants with an absorbable gentamicin collagen sheet and a periosteum and skin rotation flaps. Three patients with cochlear implant and persistent surrounding soft tissue infection are included. All of them underwent antibiotic treatment prior to surgery without any response. In this study preoperative and postoperative audiograms were practiced. Surgical excision of infectious skin and a periosteum and skin rotation flaps were performed. The cochlear implant was refixed in the temporal bone and a gentamicin-impregnated collagen sheet was located covering the cochlear implant. headings In all patients with soft tissue infection around the cochlear implant, infection was completely resolved. It was not necessary to remove the device in any case. The use of an absorbable gentamicin-impregnated collagen sheet is not described for the management of soft tissue complications in pediatric cochlear implant patients. The local application of high concentrations of antibiotic administered by this sheet may be effective against resistant bacteria and, in conjunction with surgery, may resolve this type of complications.

  20. [Study on the factors impacting on early cochlear implantation between the eastern and western region of China].

    Science.gov (United States)

    Xiao, Hanqiong; Li, Wei; Ma, Ruixia; Gong, Zhengpeng; Shi, Haibo; Li, Huawei; Chen, Bing; Jiang, Ye; Dai, Chunfu

    2015-06-01

    To describe tne regional different factors which impact on early cochlear implantation in prelingual deaf children between eastern and western regions of China. The charts of 113 children who received the cochlear implantation after 24 months old were reviewed and analyzed. Forty-five of them came from the eastern region (Jiangsu, Zhejiang or Shanghai) while 68 of them came from the western region (Ningxia or Guizhou). Parental interviews were conducted to collect information regarding the factors that impact on early cochlear implantation. Result:Based on the univariate logistic regression analysis, the odds ratio (OR) value of universal newborn hearing screening (UNHS) was 5. 481, which indicated the correlation of UNHS with early cochlear implantation is significant. There was statistical difference between the 2 groups (P0. 05). The multivariate analysis indicated that the UNHS and financial burden are statistically different between the eastern and western regions (P=0. 00 and 0. 040 respectively). The UNHS and financial burden are statistically different between the eastern reinforced in the western region. In addition, the government and society should provide powerful policy and more financial support in the western region of China. The innovation of management system is also helpful to the early cochlear implantation.

  1. Neurotrophic treatment of the degenerating auditory nerve; cochlear implants in deafened guinea pigs

    NARCIS (Netherlands)

    Agterberg, M.J.H.

    2009-01-01

    To date, the cochlear implant is the most successful sensorineural prosthesis. The device consists of a small array with a number of electrodes implanted in the cochlea of profoundly hearing impaired people. Some people with an implant are able to use the telephone. Unfortunately, others hardly

  2. Comparison of Social Interaction between Cochlear-Implanted Children with Normal Intelligence Undergoing Auditory Verbal Therapy and Normal-Hearing Children: A Pilot Study.

    Science.gov (United States)

    Monshizadeh, Leila; Vameghi, Roshanak; Sajedi, Firoozeh; Yadegari, Fariba; Hashemi, Seyed Basir; Kirchem, Petra; Kasbi, Fatemeh

    2018-04-01

    A cochlear implant is a device that helps hearing-impaired children by transmitting sound signals to the brain and helping them improve their speech, language, and social interaction. Although various studies have investigated the different aspects of speech perception and language acquisition in cochlear-implanted children, little is known about their social skills, particularly Persian-speaking cochlear-implanted children. Considering the growing number of cochlear implants being performed in Iran and the increasing importance of developing near-normal social skills as one of the ultimate goals of cochlear implantation, this study was performed to compare the social interaction between Iranian cochlear-implanted children who have undergone rehabilitation (auditory verbal therapy) after surgery and normal-hearing children. This descriptive-analytical study compared the social interaction level of 30 children with normal hearing and 30 with cochlear implants who were conveniently selected. The Raven test was administered to the both groups to ensure normal intelligence quotient. The social interaction status of both groups was evaluated using the Vineland Adaptive Behavior Scale, and statistical analysis was performed using Statistical Package for Social Sciences (SPSS) version 21. After controlling age as a covariate variable, no significant difference was observed between the social interaction scores of both the groups (p > 0.05). In addition, social interaction had no correlation with sex in either group. Cochlear implantation followed by auditory verbal rehabilitation helps children with sensorineural hearing loss to have normal social interactions, regardless of their sex.

  3. Scala vestibuli insertion in cochlear implantation: a valuable alternative for cases with obstructed scala tympani.

    Science.gov (United States)

    Kiefer, J; Weber, A; Pfennigdorff, T; von Ilberg, C

    2000-01-01

    Insertion of a sufficient number of electrodes is important for a successful use of cochlear implants. We investigated the results of scala vestibuli insertion for cochlear implantation in cases of obstructed scala tympani. In a series of 200 cochlear implantations, scala vestibuli insertion was successfully performed in 4 cases with obstruction of the scala tympani. Etiologies included a temporal bone fracture, severe otosclerosis and malformations of the cochlea. The maximum insertion depth obtained via the scala vestibuli was 30 mm. Postoperative results were comparable to patients in whom conventional scala tympani insertion was performed. No adverse effects related to the site of insertion were observed. Scala vestibuli insertion offers a valuable alternative in cases of obstructed scala tympani that can be employed for a variety of etiologies. Copyright 2000 S. Karger AG, Basel

  4. The relationship of theory of mind and executive functions in normal, deaf and cochlear-implanted children

    Directory of Open Access Journals (Sweden)

    Farideh Nazarzadeh

    2014-08-01

    Full Text Available Background and Aim : Theory of mind refers to the ability to understand the others have mental states that can be different from one's own mental states or facts. This study aimed to investigate the relationship of theory of mind and executive functions in normal hearing, deaf, and cochlear-implanted children.Methods: The study population consisted of normal, deaf and cochlear-implanted girl students in Mashhad city, Iran. Using random sampling, 30 children (10 normal, 10 deaf and 10 cochlear-implanted in age groups of 8-12 years old were selected. To measure the theoty of mind, theory of mind 38-item scale and to assess executive function, Coolidge neuropsychological and personality test was used. Research data were analyzed using the Spearman correlation coefficient, analysis of variance and Kruskal-Wallis tests.Results: There was a significant difference between the groups in the theory of mind and executive function subscales, organization, planning-decision-making, and inhibition. Between normal and deaf groups (p=0.01, as well as cochlear-implanted and deaf groups (p=0.01, there was significant difference in planning decision-making subscale. There was not any significant relationship between the theory of mind and executive functions generally or the theory of mind and executive function subscales in these three groups independently.Conclusion: Based on our findings, cochlear-implanted and deaf children have lower performance in theory of mind and executive function compared with normal hearing children.

  5. European multi-centre study of the Nucleus Hybrid L24 cochlear implant

    NARCIS (Netherlands)

    Lenarz, T.; James, C.; Cuda, D.; Fitzgerald O'Connor, A.; Frachet, B.; Frijns, J.H.M.; Klenzner, T.; Laszig, R.; Manrique, M.; Marx, M.; Merkus, P.; Mylanus, E.A.M.; Offeciers, E.; Pesch, J.; Ramos-Macias, A.; Robier, A.; Sterkers, O.; Uziel, A.

    2013-01-01

    Objectives: To investigate the preservation of residual hearing in subjects who received the Nucleus Hybrid L24 cochlear implant. To investigate the performance benefits up to one year post-implantation in terms of speech recognition, sound quality, and quality of life. Design: Prospective, with

  6. Cochlear implant users move in time to the beat of drum music.

    Science.gov (United States)

    Phillips-Silver, Jessica; Toiviainen, Petri; Gosselin, Nathalie; Turgeon, Christine; Lepore, Franco; Peretz, Isabelle

    2015-03-01

    Cochlear implant users show a profile of residual, yet poorly understood, musical abilities. An ability that has received little to no attention in this population is entrainment to a musical beat. We show for the first time that a heterogeneous group of cochlear implant users is able to find the beat and move their bodies in time to Latin Merengue music, especially when the music is presented in unpitched drum tones. These findings not only reveal a hidden capacity for feeling musical rhythm through the body in the deaf and hearing impaired population, but illuminate promising avenues for designing early childhood musical training that can engage implanted children in social musical activities with benefits potentially extending to non-musical domains. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Clinical evaluation of music perception, appraisal and experience in cochlear implant users

    Science.gov (United States)

    Drennan, Ward. R.; Oleson, Jacob J.; Gfeller, Kate; Crosson, Jillian; Driscoll, Virginia D.; Won, Jong Ho; Anderson, Elizabeth S.; Rubinstein, Jay T.

    2014-01-01

    Objectives The objectives were to evaluate the relationships among music perception, appraisal, and experience in cochlear implant users in multiple clinical settings and to examine the viability of two assessments designed for clinical use. Design Background questionnaires (IMBQ) were administered by audiologists in 14 clinics in the United States and Canada. The CAMP included tests of pitch-direction discrimination, and melody and timbre recognition. The IMBQ queried users on prior musical involvement, music listening habits pre and post implant, and music appraisals. Study sample One-hundred forty-five users of Advanced Bionics and Cochlear Ltd cochlear implants. Results Performance on pitch direction discrimination, melody recognition, and timbre recognition tests were consistent with previous studies with smaller cohorts, as well as with more extensive protocols conducted in other centers. Relationships between perceptual accuracy and music enjoyment were weak, suggesting that perception and appraisal are relatively independent for CI users. Conclusions Perceptual abilities as measured by the CAMP had little to no relationship with music appraisals and little relationship with musical experience. The CAMP and IMBQ are feasible for routine clinical use, providing results consistent with previous thorough laboratory-based investigations. PMID:25177899

  8. Predictors of Spoken Language Development Following Pediatric Cochlear Implantation

    NARCIS (Netherlands)

    Johan Frijns; prof. Dr. Louis Peeraer; van Wieringen; Ingeborg Dhooge; Vermeulen; Jan Brokx; Tinne Boons; Wouters

    2012-01-01

    Objectives: Although deaf children with cochlear implants (CIs) are able to develop good language skills, the large variability in outcomes remains a significant concern. The first aim of this study was to evaluate language skills in children with CIs to establish benchmarks. The second aim was to

  9. Cochlear Implant: the complexity involved in the decision making process by the family.

    Science.gov (United States)

    Vieira, Sheila de Souza; Bevilacqua, Maria Cecília; Ferreira, Noeli Marchioro Liston Andrade; Dupas, Giselle

    2014-01-01

    to understand the meanings the family attributes to the phases of the decision-making process on a cochlear implant for their child. qualitative research, using Symbolic Interactionism and Grounded Theory as the theoretical and methodological frameworks, respectively. Data collection instrument: semistructured interview. Nine families participated in the study (32 participants). knowledge deficit, difficulties to contextualize benefits and risks and fear are some factors that make this process difficult. Experiences deriving from interactions with health professionals, other cochlear implant users and their relatives strengthen decision making in favor of the implant. deciding on whether or not to have the implant involves a complex process, in which the family needs to weigh gains and losses, experience feelings of accountability and guilt, besides overcoming the risk aversion. Hence, this demands cautious preparation and knowledge from the professionals involved in this intervention.

  10. Electrode Impedance Fluctuations as a Biomarker for Inner Ear Pathology After Cochlear Implantation.

    Science.gov (United States)

    Choi, June; Payne, Matthew R; Campbell, Luke J; Bester, Christo W; Newbold, Carrie; Eastwood, Hayden; O'Leary, Stephen J

    2017-12-01

    Cochlear implant surgery now aims to preserve residual low frequency hearing. The current research explores whether fluctuations in the electrical impedance of cochlear implant electrodes may act as a biomarker for pathological changes that lead to the delayed loss of residual hearing. Secondary analysis of a double-blinded randomized trial, where methylprednisolone was administered intravenously before cochlear implantation with a view to preserving residual hearing. Seventy-four patients with residual hearing after cochlear implant surgery were investigated for an impedance "spike," defined as a median rise of ≥4 kΩ across all electrodes from the baseline measurements. Spikes were related to objective and subjective hearing loss, dizziness, and tinnitus. An impedance spike occurred in 14% (10/74) of enrolled patients. Three months after surgery, five patients exhibited spikes and three of these patients had a total loss of their residual hearing. 4.3% of the 69 patients without spikes lost residual hearing. At 1 year, 9 of 10 patients who exhibited spikes had lost all their residual hearing. 8.1% of the 37 patients who did not experience a spike lost their residual hearing. Seventy percent of patients exhibiting a spike also experienced vertigo. The administration of steroids at the time of surgery did not influence the occurrence of spikes. Our results suggest that there is a relationship between a spike and the loss of residual hearing. It seems that rises in impedance can reflect pathology within the inner ear and predict the future loss of residual hearing.

  11. Parents' views on the quality of life of their children 2-3 years after cochlear implantation.

    Science.gov (United States)

    Huttunen, K; Rimmanen, S; Vikman, S; Virokannas, N; Sorri, M; Archbold, S; Lutman, M E

    2009-12-01

    Cochlear implants for children are known to have impact on the lives of recipients and their families in a variety of ways. To obtain a clearer picture of these benefits, we explored the quality of life of 36 Finnish children and their families 2-3 years after unilateral cochlear implantation. The studied children were, on average 5 years old, and had received their implant at the median age of 2 years:5 months (range 1:6 to 12:3). Most (67%) of the children used speech, eight (22%) used speech and signs, and four (11%) used sign language as their main communication mode. A third of the children had concomitant problems in addition to their profound hearing impairment. A validated closed-set questionnaire "Children with cochlear implants: parental perspectives" (available, e.g., at http://www.earfoundation.org.uk/research/questionnaires.html) was used to find out parents' views and experiences on implantation and explore life after it. Parents were most satisfied with improved/expanded social relations, improved communication (the development of spoken language), general functioning with the help of hearing and improved self-reliance of the child. Benefit of cochlear implantation was also detected with the Categories of Auditory Performance (CAP), which was concordant with views of the parents on the progress of their child in the areas of communication and education. When deciding on implantation, the parents particularly expected auditory information to enhance their child's safety in traffic, joining socially the hearing world, and better employment prospects as adults. Concerning the process of implantation, parents especially valued the know-how and fluent services of the implant centre, positive attitude within the family and information received from other families during the time they were considering the implant decision. Parents also found it important that they have the possibility to influence the communication mode that is used in their child

  12. Benefit of the UltraZoom beamforming technology in noise in cochlear implant users.

    Science.gov (United States)

    Mosnier, Isabelle; Mathias, Nathalie; Flament, Jonathan; Amar, Dorith; Liagre-Callies, Amelie; Borel, Stephanie; Ambert-Dahan, Emmanuèle; Sterkers, Olivier; Bernardeschi, Daniele

    2017-09-01

    The objectives of the study were to demonstrate the audiological and subjective benefits of the adaptive UltraZoom beamforming technology available in the Naída CI Q70 sound processor, in cochlear-implanted adults upgraded from a previous generation sound processor. Thirty-four adults aged between 21 and 89 years (mean 53 ± 19) were prospectively included. Nine subjects were unilaterally implanted, 11 bilaterally and 14 were bimodal users. The mean duration of cochlear implant use was 7 years (range 5-15 years). Subjects were tested in quiet with monosyllabic words and in noise with the adaptive French Matrix test in the best-aided conditions. The test setup contained a signal source in front of the subject and three noise sources at +/-90° and 180°. The noise was presented at a fixed level of 65 dB SPL and the level of speech signal was varied to obtain the speech reception threshold (SRT). During the upgrade visit, subjects were tested with the Harmony and with the Naída CI sound processors in omnidirectional microphone configuration. After a take-home phase of 2 months, tests were repeated with the Naída CI processor with and without UltraZoom. Subjective assessment of the sound quality in daily environments was recorded using the APHAB questionnaire. No difference in performance was observed in quiet between the two processors. The Matrix test in noise was possible in the 21 subjects with the better performance. No difference was observed between the two processors for performance in noise when using the omnidirectional microphone. At the follow-up session, the median SRT with the Naída CI processor with UltraZoom was -4 dB compared to -0.45 dB without UltraZoom. The use of UltraZoom improved the median SRT by 3.6 dB (p noise and for speech understanding in noise (p noise. The use of UltraZoom beamforming technology, available on the new sound processor Naída CI, improves speech performance in difficult and realistic noisy conditions when the

  13. Cochlear-implanted children from homes where English is an additional language: findings from a recent audit in one London centre.

    Science.gov (United States)

    Mahon, M; Vickers, D; McCarthy, K; Barker, R; Merritt, R; Szagun, G; Mann, W; Rajput, K

    2011-05-01

    A 5-year retrospective audit of demographic, audiological, and other records of 147 children implanted at one London centre was conducted. The aim was to detail the number of children implanted, with a specific focus on children from families with English as an additional language (EAL), and to compare these children with children from monolingual English-speaking families on a variety of characteristics known to affect paediatric cochlear implant outcomes. In all, 28% of children were from families where English is an additional language, with 15 different languages recorded. There were no differences between EAL and English-speaking children with respect to age of implantation; bilateral versus unilateral implants or hearing levels in better ear. There were differences between these groups in aetiology, in the occurrence of additional needs, and in educational placements. Information about speech and language outcomes was difficult to gather. Conclusions indicate the need for more detailed record-keeping especially about children's home languages for purposes of planning intervention and for the inclusion of children with EAL in future studies.

  14. Surgical considerations and safety of cochlear implantation in otitis media with effusion.

    Science.gov (United States)

    Cevizci, Rasit; Dilci, Alper; Celenk, Fatih; Karamert, Recep; Bayazit, Yildirim

    2018-06-01

    To evaluate the effects of otitis media with effusion on surgical parameters, patient safety, perioperative and postoperative complications. Total 890 children who underwent cochlear implantation between 2006 and 2015 were included. The ages ranged from 12 months to 63 months (mean: 32 months). The patients were divided into two groups according to the presence or absence of otitis media with effusion; otitis media with effusion group and non-otitis media group. Of 890 children, 105 had otitis media with effusion prior to surgery. In non-otitis media with group, there were 785 children. The average duration of surgery was 60min (ranged from 28 to 75min) in non-otitis media group, and 90min (ranged from 50 to 135min) in otitis media with effusion group (peffusion during the surgery. There was no significant difference between the complications of groups with or without otitis media with effusion (p>0.05). In 5 of 105 patients, there was a ventilation tube inserted before cochlear implantation, which did not change the outcome of implantation. There is no need for surgical treatment for otitis media with effusion before implantation since otitis media with effusion does not increase the risks associated with cochlear implantation. Operation duration is longer in the presence of otitis media with effusion. However, otitis media with effusion leads to intraoperative difficulties like longer operation duration, bleeding, visualization of the round window membrane, cleansing the middle ear granulations as well as mastoid and petrous air cells. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Deafness-related self-perceptions and psychological well-being in deaf adolescents with cochlear implants.

    Science.gov (United States)

    Mance, Jennifer; Edwards, Lindsey

    2012-05-01

    This study aimed to examine the relationship between psychological well-being and self-perception in adolescents with cochlear implants, in relation to their perceptions of hearing, deaf signing, and orally communicating deaf peers. Self-perceptions were examined in 22 cochlear implant users aged 12-18 years, using the repertory grid technique that allows the respondent to generate personally relevant 'identity' constructs. Psychological well-being was assessed using the Beck Youth Inventory, a series of five self-report questionnaires assessing anxiety, depression, disruptive behaviour, anger, and self-esteem. Correlational analyses indicated that perceiving oneself as close to any peer, irrespective of which peer, was associated with better psychological well-being. There was also a significant positive association between perceived degree of similarity specifically to hearing peers, and psychological well-being. The closer the implanted adolescents perceived themselves to be to their hearing peers, the better their overall psychological well-being. In contrast, perceiving oneself as more similar to deaf signing peers or deaf oral peers was not significantly associated with psychological well-being. The findings are discussed in the context of previous research on social comparison, Deaf identity, and the aims of cochlear implantation.

  16. Factors associated with hearing loss in a normal-hearing guinea pig model of Hybrid cochlear implants.

    Science.gov (United States)

    Tanaka, Chiemi; Nguyen-Huynh, Anh; Loera, Katherine; Stark, Gemaine; Reiss, Lina

    2014-10-01

    The Hybrid cochlear implant (CI), also known as Electro-Acoustic Stimulation (EAS), is a new type of CI that preserves residual acoustic hearing and enables combined cochlear implant and hearing aid use in the same ear. However, 30-55% of patients experience acoustic hearing loss within days to months after activation, suggesting that both surgical trauma and electrical stimulation may cause hearing loss. The goals of this study were to: 1) determine the contributions of both implantation surgery and EAS to hearing loss in a normal-hearing guinea pig model; 2) determine which cochlear structural changes are associated with hearing loss after surgery and EAS. Two groups of animals were implanted (n = 6 per group), with one group receiving chronic acoustic and electric stimulation for 10 weeks, and the other group receiving no direct acoustic or electric stimulation during this time frame. A third group (n = 6) was not implanted, but received chronic acoustic stimulation. Auditory brainstem response thresholds were followed over time at 1, 2, 6, and 16 kHz. At the end of the study, the following cochlear measures were quantified: hair cells, spiral ganglion neuron density, fibrous tissue density, and stria vascularis blood vessel density; the presence or absence of ossification around the electrode entry was also noted. After surgery, implanted animals experienced a range of 0-55 dB of threshold shifts in the vicinity of the electrode at 6 and 16 kHz. The degree of hearing loss was significantly correlated with reduced stria vascularis vessel density and with the presence of ossification, but not with hair cell counts, spiral ganglion neuron density, or fibrosis area. After 10 weeks of stimulation, 67% of implanted, stimulated animals had more than 10 dB of additional threshold shift at 1 kHz, compared to 17% of implanted, non-stimulated animals and 0% of non-implanted animals. This 1-kHz hearing loss was not associated with changes in any of the cochlear measures

  17. Cochlear Implant: the complexity involved in the decision making process by the family

    Directory of Open Access Journals (Sweden)

    Sheila de Souza Vieira

    2014-06-01

    Full Text Available OBJECTIVE: to understand the meanings the family attributes to the phases of the decision-making process on a cochlear implant for their child.METHOD: qualitative research, using Symbolic Interactionism and Grounded Theory as the theoretical and methodological frameworks, respectively. Data collection instrument: semistructured interview. Nine families participated in the study (32 participants.RESULTS: knowledge deficit, difficulties to contextualize benefits and risks and fear are some factors that make this process difficult. Experiences deriving from interactions with health professionals, other cochlear implant users and their relatives strengthen decision making in favor of the implant.CONCLUSION: deciding on whether or not to have the implant involves a complex process, in which the family needs to weigh gains and losses, experience feelings of accountability and guilt, besides overcoming the risk aversion. Hence, this demands cautious preparation and knowledge from the professionals involved in this intervention.

  18. Classroom performance of children with cochlear implants in mainstream education.

    NARCIS (Netherlands)

    Damen, G.W.J.A.; Oever-Goltstein, M.H. van den; Langereis, M.C.; Chute, P.M.; Mylanus, E.A.M.

    2006-01-01

    OBJECTIVES: We compared classroom performance of children with a cochlear implant (CI) with that of their normal-hearing peers in mainstream education. METHODS: Thirty-two CI children in mainstream education, congenitally or prelingually deaf, participated in this study, as did 37 hearing

  19. Simultaneous communication supports learning in noise by cochlear implant users

    NARCIS (Netherlands)

    Blom, H.C.; Marschark, M.; Machmer, E.

    2017-01-01

    Objectives: This study sought to evaluate the potential of using spoken language and signing together (simultaneous communication, SimCom, sign-supported speech) as a means of improving speech recognition, comprehension, and learning by cochlear implant (CI) users in noisy contexts.Methods: Forty

  20. Use of Vaccines to Prevent Meningitis in Persons with Cochlear Implants

    Science.gov (United States)

    ... Before Traveling Related Links Vaccines & Immunizations Use of Vaccines to Prevent Meningitis in Persons with Cochlear Implants ... For More Information References One of the Recommended Vaccines by Disease What You Should Know People with ...

  1. Developmental dysgraphia with profound hearing impairment: intervention by auditory methods enabled by cochlear implant.

    Science.gov (United States)

    Fukushima, Kunihiro; Kawasaki, Akihiro; Nagayasu, Rie; Kunisue, Kazuya; Maeda, Yukihide; Kariya, Shin; Kataoka, Yuko; Nishizaki, Kazunori

    2008-06-01

    Learning disability combined with hearing impairment (LDHI) is a poor prognostic factor for the language development of hearing impaired children after educational intervention. A typical example of a child with LDHI and effective interventions provided by cochlear implants are presented in this report. A case of congenital cytomegaloviral infection that showed dysgraphia as well as profound deafness was reported and an underlying visual processing problem diagnosed in the present case caused the patient's dysgraphia. The dysgraphia could be circumvented by the use of auditory memory fairly established by a cochlear implant.

  2. An image guidance system for positioning robotic cochlear implant insertion tools

    Science.gov (United States)

    Bruns, Trevor L.; Webster, Robert J.

    2017-03-01

    Cochlear implants must be inserted carefully to avoid damaging the delicate anatomical structures of the inner ear. This has motivated several approaches to improve the safety and efficacy of electrode array insertion by automating the process with specialized robotic or manual insertion tools. When such tools are used, they must be positioned at the entry point to the cochlea and aligned with the desired entry vector. This paper presents an image guidance system capable of accurately positioning a cochlear implant insertion tool. An optical tracking system localizes the insertion tool in physical space while a graphical user interface incorporates this with patient- specific anatomical data to provide error information to the surgeon in real-time. Guided by this interface, novice users successfully aligned the tool with an mean accuracy of 0.31 mm.

  3. Cochlear implantation in Mondini's deformity: could the straight electrode array with length of 31 mm be fully inserted?

    Science.gov (United States)

    Sun, Jia-Qiang; Sun, Jing-Wu; Hou, Xiao-Yan

    2017-07-01

    The straight electrode array with length of 31 mm can be fully inserted using round window insertion in cochlear implantation with Mondini's deformity. It is a safe and effective process, but also a challenging task of the full implantation in children with Mondini's deformity. The aim of this study is to discuss whether the straight electrode array with a length of 31 mm could be fully inserted in cochlear implantation with Mondini's deformity. A chart review of 30 patients undergoing cochlear implantation with Mondini's deformity using the electrode array with length of 31 mm was undertaken from January 2012 and December 2015 in Anhui Provincial Hospital. Full insertion of the straight electrode array with length of 31 mm were performed successfully in all patients with Mondini's deformity using round window insertion. Resistance was not encountered while introducing the electrodes. Ten of 30 patients had cerebrospinal fluid drainage during cochlear implantation. Cerebrospinal fluid drainage was controlled with small pieces of temporalis fascia packing round window in all patients. Intra-operative neural response telemetry was performed in all patients, and results were good. The result of X-ray showed proper placement of the cochlear implant electrode array. During surgery, no patients had experienced any immediate or delayed post-operative complications such as wound infection, intracranial complication, extrusion, or migration of the implant during an average follow-up period of 6-36 months.

  4. GDP Matters: Cost Effectiveness of Cochlear Implantation and Deaf Education in Sub-Saharan Africa.

    Science.gov (United States)

    Emmett, Susan D; Tucci, Debara L; Smith, Magteld; Macharia, Isaac M; Ndegwa, Serah N; Nakku, Doreen; Mukara, Kaitesi B; Kaitesi, Mukara B; Ibekwe, Titus S; Mulwafu, Wakisa; Gong, Wenfeng; Francis, Howard W; Saunders, James E

    2015-09-01

    Cochlear implantation and deaf education are cost effective in Sub-Saharan Africa. Cost effectiveness of pediatric cochlear implantation has been well established in developed countries but is unknown in low resource settings, where access to the technology has traditionally been limited. With incidence of severe-to-profound congenital sensorineural hearing loss 5 to 6 times higher in low/middle-income countries than the United States and Europe, developing cost-effective management strategies in these settings is critical. Costs were obtained from experts in Nigeria, South Africa, Kenya, Rwanda, Uganda, and Malawi using known costs and published data, with estimation when necessary. A disability adjusted life years (DALY) model was applied using 3% discounting and 10-year length of analysis. Sensitivity analysis was performed to evaluate the effect of device cost, professional salaries, annual number of implants, and probability of device failure. Cost effectiveness was determined using the WHO standard of cost-effectiveness ratio/gross domestic product per capita (CER/GDP) less than 3. Cochlear implantation was cost effective in South Africa and Nigeria, with CER/GDP of 1.03 and 2.05, respectively. Deaf education was cost effective in all countries investigated, with CER/GDP ranging from 0.55 to 1.56. The most influential factor in the sensitivity analysis was device cost, with the cost-effective threshold reached in all countries using discounted device costs that varied directly with GDP. Cochlear implantation and deaf education are equally cost effective in lower-middle and upper-middle income economies of Nigeria and South Africa. Device cost may have greater impact in the emerging economies of Kenya, Uganda, Rwanda, and Malawi.

  5. [Meta-analysis of the efficacy of cochlear implantation in deaf patients with inner ear malformation].

    Science.gov (United States)

    Xu, Qingqing; Zhai, Suoqiang; Han, Dongyi; Yang, Shiming; Shen, Weidong

    2014-04-01

    Assess and compare the clinical efficacy and safety of cochlear implantation in deaf patients with inner ear malformation and in the ones with normal inner ear structure, so that to clarify whether it is effective to restore hearing for the deaf patients with inner ear malformation. The literature with relevant key words were retrieved in the databases including PubMed, YZ365. com, WANFANG data, CMJD, CHKD and CNKI with language limited to Chinese and English. Extracted data included author, year of publication, diagnosis, treatment, et al. The clinical efficacy of cochlear implantation was assessed by the complications, electrode impedance, behavior T-level, hearing abilities and speech discrimination. Meta-analysis was performed using random or fixed effects model according to the heterogeneity of data. There were 11 randomized control studies involving 655 patients included in this study. There was no statistically significant difference among the deaf patients in mixed inner ear-malformation group, Mondini group and large vestibular aqueduct syndrome group in the aspects of postoperative complications, electrode impedance, behavior T-level, hearing abilities and speech discrimination. Cochlear implantation could be the way of treatment and rehabilitation for deaf patients with inner ear malformation. Further controlled studies with longer follow-up periods and more multiracial cases included may help to evaluate the efficacy of cochlear implantation for deaf patients with inner ear malformation more reliably.

  6. Investigation of Balance Function Using Dynamic Posturography under Electrical-Acoustic Stimulation in Cochlear Implant Recipients

    Directory of Open Access Journals (Sweden)

    B. Schwab

    2010-01-01

    Full Text Available Introduction. The purpose of the present study is to investigate the effect of electrical-acoustic stimulation on vestibular function in CI patients by using the EquiTest and to help answer the question of whether electrically stimulating the inner ear using a cochlear implant influences the balance system in any way. Material and Methods. A test population (=50 was selected at random from among the cochlear implant recipients. Dynamic posturography (using the EquiTest was performed with the device switched off an switched on. Results. In summary, it can be said that an activated cochlear implant affects the function of the vestibular system and may, to an extent, even lead to a stabilization of balance function under the static conditions of dynamic posturography, but nevertheless also to a significant destabilization. Significant improvements in vestibular function were seen mainly in equilibrium scores under conditions 4 and 5, the composite equilibrium score, and the vestibular components as revealed by sensory analysis. Conclusions. Only under the static conditions are significantly poorer scores achieved when stimulation is applied. It may be that the explanation for any symptoms of dizziness lies precisely in the fact that they occur in supposedly noncritical situations, since, when the cochlear implant makes increased demands on the balance system, induced disturbances can be centrally suppressed.

  7. Outcomes and Time to Emergence of Auditory Skills After Cochlear Implantation of Children With Charge Syndrome.

    Science.gov (United States)

    Young, Nancy M; Tournis, Elizabeth; Sandy, Jenelle; Hoff, Stephen R; Ryan, Maura

    2017-09-01

    Review perioperative complications, benefits, and the timeframe over which auditory skills develop in children with CHARGE syndrome who receive a cochlear implant (CI). IRB-approved retrospective chart review of children with CHARGE syndrome who had at least 12 months of cochlear implant use. Tertiary care children's hospital. Twelve children, seven males and five females. Mean age implant = 3.5 years (1.7-8.2 yr); mean duration follow-up = 4.7 years (1.5-10.1 yr). Cochlear implantation. Auditory skills categorized into four levels, temporal bone imaging findings, perioperative complications, time to emergence of speech perception, expressive communication mode. All children imaged with magnetic resonance imaging had cochlear nerve deficiency in at least one ear. Speech awareness threshold improved with the CI compared with aided preoperative in 83% of children, with means of 51.7 dB SAT preoperative and 27.1 dB with the CI (p ≤ 0.002). Overall, four children improved to auditory Level 2 (improved detection), three obtained Level 3 (closed-set speech perception), and three had open-set speech perception with their CIs (Level 4) that was first evident at 3.5, 3.3, and 0.8 years postimplant testing. Two children had minimal or limited improvement. One child with hypoplasia of the cochlear nerve obtained open-set levels. Auditory skills may develop slowly in children with CHARGE syndrome who receive a CI but most can achieve at least improved detection. In our series, half acquired some speech perception ability. Cochlear nerve deficiency is frequent, but should not be a contraindication to implantation.

  8. Vestibular Function After Cochlear Implantation: A Comparison of Three Types of Electrodes.

    Science.gov (United States)

    Frodlund, Jonas; Harder, Henrik; Mäki-Torkko, Elina; Ledin, Torbjörn

    2016-12-01

    To investigate the vestibular function after cochlear implantation with different types of electrode arrays. Retrospective cohort study. Academic tertiary referral center. Forty three adults underwent first cochlear implantation. Three consecutive series of patients: Group 1 (n = 13) implanted with a precurved electrode, Group 2 (n = 15) implanted with a straight electrode, Group 3 (n = 15) implanted with a flexible electrode. Patient's vestibular functions were assessed with pre- and postoperative caloric testing using videonystagmography (VNG). The postoperative reduction of the maximum slow phase velocity (MSPV) in the implanted ear was evaluated. Medical charts were reviewed to evaluate the occurrence of late onset of postoperative vestibular symptoms. Mean reduction of MSPV was 7.6/s (standard deviation [SD] 8.0) in Group 1, 23.1/s (SD 16.6) in Group 2, and 0.1/s (SD 18.5) in Group 3. Significant difference was found between Group 1 and 2 (p < 0.030) and between Group 2 and 3 (p < 0.001). Group 2 showed a higher prevalence of late onset of clinical vertigo (28.6%) than Group 1 (7.7%) and 3 (6.7%). In this prospective study, significantly larger reductions of caloric responses were found in subjects implanted with a straight electrode compared with subjects implanted with a precurved or flexible electrode. These findings seem to correlate to a higher prevalence of postoperative vertigo.

  9. Delayed access to bilateral input alters cortical organization in children with asymmetric hearing

    Directory of Open Access Journals (Sweden)

    Melissa Jane Polonenko

    2018-01-01

    Full Text Available Bilateral hearing in early development protects auditory cortices from reorganizing to prefer the better ear. Yet, such protection could be disrupted by mismatched bilateral input in children with asymmetric hearing who require electric stimulation of the auditory nerve from a cochlear implant in their deaf ear and amplified acoustic sound from a hearing aid in their better ear (bimodal hearing. Cortical responses to bimodal stimulation were measured by electroencephalography in 34 bimodal users and 16 age-matched peers with normal hearing, and compared with the same measures previously reported for 28 age-matched bilateral implant users. Both auditory cortices increasingly favoured the better ear with delay to implanting the deaf ear; the time course mirrored that occurring with delay to bilateral implantation in unilateral implant users. Preference for the implanted ear tended to occur with ongoing implant use when hearing was poor in the non-implanted ear. Speech perception deteriorated with longer deprivation and poorer access to high-frequencies. Thus, cortical preference develops in children with asymmetric hearing but can be avoided by early provision of balanced bimodal stimulation. Although electric and acoustic stimulation differ, these inputs can work sympathetically when used bilaterally given sufficient hearing in the non-implanted ear.

  10. Implicit sequence learning in deaf children with cochlear implants.

    Science.gov (United States)

    Conway, Christopher M; Pisoni, David B; Anaya, Esperanza M; Karpicke, Jennifer; Henning, Shirley C

    2011-01-01

    Deaf children with cochlear implants (CIs) represent an intriguing opportunity to study neurocognitive plasticity and reorganization when sound is introduced following a period of auditory deprivation early in development. Although it is common to consider deafness as affecting hearing alone, it may be the case that auditory deprivation leads to more global changes in neurocognitive function. In this paper, we investigate implicit sequence learning abilities in deaf children with CIs using a novel task that measured learning through improvement to immediate serial recall for statistically consistent visual sequences. The results demonstrated two key findings. First, the deaf children with CIs showed disturbances in their visual sequence learning abilities relative to the typically developing normal-hearing children. Second, sequence learning was significantly correlated with a standardized measure of language outcome in the CI children. These findings suggest that a period of auditory deprivation has secondary effects related to general sequencing deficits, and that disturbances in sequence learning may at least partially explain why some deaf children still struggle with language following cochlear implantation. © 2010 Blackwell Publishing Ltd.

  11. Intracochlear Position of Cochlear Implants Determined Using CT Scanning versus Fitting Levels: Higher Threshold Levels at Basal Turn

    NARCIS (Netherlands)

    Beek, F.B. van der; Briaire, J.J.; Marel, K.S. van der; Verbist, B.M.; Frijns, J.H.

    2016-01-01

    OBJECTIVES: In this study, the effects of the intracochlear position of cochlear implants on the clinical fitting levels were analyzed. DESIGN: A total of 130 adult subjects who used a CII/HiRes 90K cochlear implant with a HiFocus 1/1J electrode were included in the study. The insertion angle and

  12. Word learning in deaf children with cochlear implants: effects of early auditory experience.

    Science.gov (United States)

    Houston, Derek M; Stewart, Jessica; Moberly, Aaron; Hollich, George; Miyamoto, Richard T

    2012-05-01

    Word-learning skills were tested in normal-hearing 12- to 40-month-olds and in deaf 22- to 40-month-olds 12 to 18 months after cochlear implantation. Using the Intermodal Preferential Looking Paradigm (IPLP), children were tested for their ability to learn two novel-word/novel-object pairings. Normal-hearing children demonstrated learning on this task at approximately 18 months of age and older. For deaf children, performance on this task was significantly correlated with early auditory experience: Children whose cochlear implants were switched on by 14 months of age or who had relatively more hearing before implantation demonstrated learning in this task, but later implanted profoundly deaf children did not. Performance on this task also correlated with later measures of vocabulary size. Taken together, these findings suggest that early auditory experience facilitates word learning and that the IPLP may be useful for identifying children who may be at high risk for poor vocabulary development. © 2012 Blackwell Publishing Ltd.

  13. Parametric model of the scala tympani for haptic-rendered cochlear implantation.

    Science.gov (United States)

    Todd, Catherine; Naghdy, Fazel

    2005-01-01

    A parametric model of the human scala tympani has been designed for use in a haptic-rendered computer simulation of cochlear implant surgery. It will be the first surgical simulator of this kind. A geometric model of the Scala Tympani has been derived from measured data for this purpose. The model is compared with two existing descriptions of the cochlear spiral. A first approximation of the basilar membrane is also produced. The structures are imported into a force-rendering software application for system development.

  14. The cochlear nerve canal and internal auditory canal in children with normal cochlea but cochlear nerve deficiency

    International Nuclear Information System (INIS)

    Yan, Fei; Li, Jianhong; Xian, Junfang; Wang, Zhenchang; Mo, Lingyan

    2013-01-01

    Background: There is an increasing frequency of requests for cochlear implantation (CI) in deaf children and more detailed image information is necessary for selecting appropriate candidates. Cochlear nerve deficiency (CND) is a contraindication to CI. Magnetic resonance imaging (MRI) has been used to evaluate the integrity of the cochlear nerve. The abnormalities of the cochlear nerve canal (CNC) and internal auditory canal (IAC) have been reported to be associated with CND. Purpose: To correlate CNC manifestation, size, and IAC diameter on high-resolution CT (HRCT) with CND diagnosed by MRI in children. Material and Methods: HRCT images from 35 sensorineurally deaf children who had normal cochlea but bilateral or unilateral CND diagnosed by MRI were studied retrospectively. The CNC and IAC manifestation and size were assessed and correlated with CND. Results: CND was diagnosed by MRI in 54/70 ears (77.1%). Thirty-two ears had an absent cochlear nerve (59.3%), while 22 ears had a small cochlear nerve (40.7%). The CNC diameter was 2.0 mm in 11 ears (20.4%). The IAC diameter was 3.0 mm in 29 ears (53.7%). Conclusion: The hypoplastic CNC might be more highly indicative of CND than that of a narrow IAC

  15. Design of a new electrode array for cochlear implants

    International Nuclear Information System (INIS)

    Kha, H.; Chen, B.

    2010-01-01

    Full text: This study aims to design a new electrode array which can be precisely located beneath the basilar membrane within the cochlear scala tympani. This placement of the electrode array is beneficial for increasing the effectiveness of the electrical stimulation of the audi tory nerves and maximising the growth factors delivered into the cochlea for regenerating the progressively lost auditory neurons, thereby significantly improving performance of the cochlear implant systems. Methods The design process involved two steps. First, the biocom patible nitinol-based shape memory alloy, of which mechanical deformation can be controlled using electrical cUTents/fields act vated by body temperature, was selected. Second, five different designs of the electrode array with embedded nitinol actuators were studied (Table I). The finite element method was employed to predict final positions of these electrode arrays. Results The electrode array with three 6 mm actuators at 2-8, 8-J4 and 14-20 mm from the tip (Fig. I) was found to be located most closely to the basilar membrane, compared with those in the other four cases. Conclusions A new nitinol cochlear implant electrode array with three embedded nitinol actuators has been designed. This electrode array is expected to be located beneath the basilar membrane for maximising the delivery of growth factors. Future research will involve the manufacturing of a prototype of this electrode array for use in insertion experiments and neurotrophin release tests.

  16. Aspectos bioéticos e médico-legais do implante coclear em crianças Bioethics and medical/legal considerations on cochlear implants in children

    Directory of Open Access Journals (Sweden)

    Ivan Dieb Miziara

    2012-06-01

    Full Text Available Implante coclear é a melhor forma de correção da surdez profunda nas formas congênitas. As crianças "implantáveis" são tidas como "vulneráveis", recaindo a decisão de se implantar sobre os responsáveis. Pelo Código Penal Brasileiro, o surdo-mudo pode ter sua imputabilidade reduzida. Existem controvérsias bioéticas a respeito do implante, pois parcela dos representantes da chamada "comunidade de surdos" vê nele uma maneira de "dizimar" sua cultura e valores intrínsecos. OBJETIVOS: Discutir em termos bioéticos a validade de se realizar implante coclear em criança, analisando a sua vulnerabilidade e os aspectos socioculturais do problema, e discutir aspectos médico-legais a respeito da imputabilidade do surdo-mudo. MATERIAL E MÉTODOS: Forma de estudo: pesquisou-se o tema nas bases de dados Medline e Lilacs e a análise ética foi baseada na Bioética Principialista. RESULTADOS: O implante coclear é a melhor opção terapêutica para correção da surdez profunda, estando moralmente justificado. Quanto à imputabilidade penal do surdo-mudo é necessário analisar seu grau de entendimento e autodeterminação à época dos fatos a ele imputados. CONCLUSÕES: O implante coclear é moralmente válido. Sua aplicação deverá ser analisada em cada caso, cabendo ao otorrinolaringologista a responsabilidade ética pela indicação, após assinatura de termo de consentimento pelos responsáveis pela criança.Cochlear implants are the best treatment for congenital profound deafness. Pediatric candidates to implantation are seen as vulnerable citizens, and the decision of implanting cochlear devices is ultimately in the hands of their parents/guardians. The Brazilian Penal Code dictates that deaf people may enjoy diminished criminal capacity. Many are the bioethical controversies around cochlear implants, as representatives from the deaf community have seen in them a means of decimating their culture and intrinsic values. OBJECTIVE: This

  17. “REPRESENTATION, PROJECTION AND COCHLEAR IMPLANT: A SINGLE CASE STUDY”

    Directory of Open Access Journals (Sweden)

    Carmela Mento

    2014-06-01

    Full Text Available From the psychological point of view hearing is an essential sensory modality for the human species, because it contributes to the formation of the first relational connections and emotions. It is important to make a diagnosis early to intervene and limit negative effects.  Deafness is a particular phenomenon (onset, types,  in this paper we undertake a thorough descriptive analysis on all aspects of deafness, in particular the use of a prosthetic device known as cochlear implant.  We have deepened personality variables in a single case with the use of Rorschach Test and Draw-a-person-Test.  We aimed to study, with the clinical interpretation of instruments, which personality variables could be involved in hearing loss condition and Cochlear Implant (CI.  This observational study highlights the psychological dynamics that should be taken into account by operators team, in order to improve the quality of life of these patients and increase their long-term therapeutic outcome.

  18. Outcomes and benefits of pediatric cochlear implantation in children with additional disabilities: a review and report of family influences on outcomes

    Directory of Open Access Journals (Sweden)

    Cejas I

    2015-05-01

    Full Text Available Ivette Cejas,1 Michael F Hoffman,2 Alexandra L Quittner21Department of Otolaryngology, University of Miami Miller School of Medicine, 2Department of Psychology, University of Miami, Miami, FL, USAAbstract: The number of children with hearing loss with additional disabilities receiving cochlear implantation has increased dramatically over the past decade. However, little is known about their auditory and speech and language development following implantation. The purpose of this review is to evaluate the effects of cochlear implantation on the most common genetic and developmental disorders in children with hearing loss. Benefits of cochlear implantation for children with autism spectrum disorder, developmental delay, CHARGE syndrome, cerebral palsy, learning disorders, Usher syndrome, Waardenburg syndrome, and attention deficit/hyperactivity disorder are reviewed. Our review indicates that children with hearing loss and additional disabilities benefit from cochlear implantation, especially when implanted early. Thus, early interventions seem as important for these children as for deaf children without additional disabilities. Comparisons of outcomes across these disabilities indicate that children with little to no cognitive impairment (eg, Waardenburg sydrome, attention deficit hyperactivity disorder have better outcomes than those with greater deficits in intellectual functioning (eg, autism, CHARGE syndrome. In addition, parents of children with hearing loss and additional disabilities report higher levels of parenting stress and greater child behavior problems than those without comorbid diagnoses. However, these parents are as sensitive when interacting with their children as parents with typically developing children using cochlear implantation. Given these results, it is critical to evaluate these children's developmental milestones to provide early implantation and intervention, appropriately counsel families regarding realistic

  19. Outcomes and benefits of pediatric cochlear implantation in children with additional disabilities: a review and report of family influences on outcomes.

    Science.gov (United States)

    Cejas, Ivette; Hoffman, Michael F; Quittner, Alexandra L

    2015-01-01

    The number of children with hearing loss with additional disabilities receiving cochlear implantation has increased dramatically over the past decade. However, little is known about their auditory and speech and language development following implantation. The purpose of this review is to evaluate the effects of cochlear implantation on the most common genetic and developmental disorders in children with hearing loss. Benefits of cochlear implantation for children with autism spectrum disorder, developmental delay, CHARGE syndrome, cerebral palsy, learning disorders, Usher syndrome, Waardenburg syndrome, and attention deficit/hyperactivity disorder are reviewed. Our review indicates that children with hearing loss and additional disabilities benefit from cochlear implantation, especially when implanted early. Thus, early interventions seem as important for these children as for deaf children without additional disabilities. Comparisons of outcomes across these disabilities indicate that children with little to no cognitive impairment (eg, Waardenburg sydrome, attention deficit hyperactivity disorder) have better outcomes than those with greater deficits in intellectual functioning (eg, autism, CHARGE syndrome). In addition, parents of children with hearing loss and additional disabilities report higher levels of parenting stress and greater child behavior problems than those without comorbid diagnoses. However, these parents are as sensitive when interacting with their children as parents with typically developing children using cochlear implantation. Given these results, it is critical to evaluate these children's developmental milestones to provide early implantation and intervention, appropriately counsel families regarding realistic expectations for the implant, and facilitate family adaptation.

  20. The impact of cochlear implantation on speech understanding, subjective hearing performance, and tinnitus perception in patients with unilateral severe to profound hearing loss.

    Science.gov (United States)

    Távora-Vieira, Dayse; Marino, Roberta; Acharya, Aanand; Rajan, Gunesh P

    2015-03-01

    This study aimed to determine the impact of cochlear implantation on speech understanding in noise, subjective perception of hearing, and tinnitus perception of adult patients with unilateral severe to profound hearing loss and to investigate whether duration of deafness and age at implantation would influence the outcomes. In addition, this article describes the auditory training protocol used for unilaterally deaf patients. This is a prospective study of subjects undergoing cochlear implantation for unilateral deafness with or without associated tinnitus. Speech perception in noise was tested using the Bamford-Kowal-Bench speech-in-noise test presented at 65 dB SPL. The Speech, Spatial, and Qualities of Hearing Scale and the Abbreviated Profile of Hearing Aid Benefit were used to evaluate the subjective perception of hearing with a cochlear implant and quality of life. Tinnitus disturbance was measured using the Tinnitus Reaction Questionnaire. Data were collected before cochlear implantation and 3, 6, 12, and 24 months after implantation. Twenty-eight postlingual unilaterally deaf adults with or without tinnitus were implanted. There was a significant improvement in speech perception in noise across time in all spatial configurations. There was an overall significant improvement on the subjective perception of hearing and quality of life. Tinnitus disturbance reduced significantly across time. Age at implantation and duration of deafness did not influence the outcomes significantly. Cochlear implantation provided significant improvement in speech understanding in challenging situations, subjective perception of hearing performance, and quality of life. Cochlear implantation also resulted in reduced tinnitus disturbance. Age at implantation and duration of deafness did not seem to influence the outcomes.

  1. Assessment of Spectral and Temporal Resolution in Cochlear Implant Users Using Psychoacoustic Discrimination and Speech Cue Categorization.

    Science.gov (United States)

    Winn, Matthew B; Won, Jong Ho; Moon, Il Joon

    This study was conducted to measure auditory perception by cochlear implant users in the spectral and temporal domains, using tests of either categorization (using speech-based cues) or discrimination (using conventional psychoacoustic tests). The authors hypothesized that traditional nonlinguistic tests assessing spectral and temporal auditory resolution would correspond to speech-based measures assessing specific aspects of phonetic categorization assumed to depend on spectral and temporal auditory resolution. The authors further hypothesized that speech-based categorization performance would ultimately be a superior predictor of speech recognition performance, because of the fundamental nature of speech recognition as categorization. Nineteen cochlear implant listeners and 10 listeners with normal hearing participated in a suite of tasks that included spectral ripple discrimination, temporal modulation detection, and syllable categorization, which was split into a spectral cue-based task (targeting the /ba/-/da/ contrast) and a timing cue-based task (targeting the /b/-/p/ and /d/-/t/ contrasts). Speech sounds were manipulated to contain specific spectral or temporal modulations (formant transitions or voice onset time, respectively) that could be categorized. Categorization responses were quantified using logistic regression to assess perceptual sensitivity to acoustic phonetic cues. Word recognition testing was also conducted for cochlear implant listeners. Cochlear implant users were generally less successful at utilizing both spectral and temporal cues for categorization compared with listeners with normal hearing. For the cochlear implant listener group, spectral ripple discrimination was significantly correlated with the categorization of formant transitions; both were correlated with better word recognition. Temporal modulation detection using 100- and 10-Hz-modulated noise was not correlated either with the cochlear implant subjects' categorization of

  2. Cochlear Implantation in Patients with Keratitis-Ichthyosis-Deafness Syndrome: A Report of Two Cases

    Directory of Open Access Journals (Sweden)

    Birgul Gumus

    2017-01-01

    Full Text Available Background. Keratitis-ichthyosis-deafness (KID syndrome is a syndrome which presents with hearing loss and visual and keratinization disorders. In such patients, hearing aids cannot be effectively used in the rehabilitation of hearing loss because of the frequent blockage of the external ear canal with epithelial debris and due to dry and tense skin of the external ear canal. Moreover, severe or profound hearing loss also limits the benefits gained from the conventional hearing aids. On the other hand, cochlear implantation is a method that has been used in limited cases in the literature. Case Report. This study presents the results of cochlear implantation applied in our clinic to two children who had been diagnosed with KID. Audiological assessments before and after the cochlear implant operation were performed using pure-tone audiometry, immittance audiometry, and auditory brainstem response (ABR, and the postoperative follow-up was conducted using pure-tone audiometry. Conclusion. Skin problems, visual disturbances, and other additional problems complicate the short-term and long-term rehabilitation after implantation in individuals with KID syndrome. Close monitoring should be exercised due to possible skin complications that may develop during the postoperative period. The families and rehabilitation teams should be warned about the possible visual disturbances and skin complications.

  3. Research Paper: Relationship of Parent-Child Stress with Cochlear Implanted Children’s Developmental Skills

    Directory of Open Access Journals (Sweden)

    Salar Faramarzi

    2016-07-01

    Conclusion The results of this study showed that parent-child stress had a significant effect on developmental skills of children with cochlear implants. Due to the importance of developmental skills in children with cochlear implants, the results of this study warned the need to provide counseling and psychological support for this group of parents. Accordingly, the programs should be offered in the form of workshops for mothers of these children. Also, psychologists and family counselors and experts in family therapy are recommended to have special attention to the role of stress in parent-child relationships in treatment programs and training.

  4. The effect of different cochlear implant microphones on acoustic hearing individuals’ binaural benefits for speech perception in noise

    Science.gov (United States)

    Aronoff, Justin M.; Freed, Daniel J.; Fisher, Laurel M.; Pal, Ivan; Soli, Sigfrid D.

    2011-01-01

    Objectives Cochlear implant microphones differ in placement, frequency response, and other characteristics such as whether they are directional. Although normal hearing individuals are often used as controls in studies examining cochlear implant users’ binaural benefits, the considerable differences across cochlear implant microphones make such comparisons potentially misleading. The goal of this study was to examine binaural benefits for speech perception in noise for normal hearing individuals using stimuli processed by head-related transfer functions (HRTFs) based on the different cochlear implant microphones. Design HRTFs were created for different cochlear implant microphones and used to test participants on the Hearing in Noise Test. Experiment 1 tested cochlear implant users and normal hearing individuals with HRTF-processed stimuli and with sound field testing to determine whether the HRTFs adequately simulated sound field testing. Experiment 2 determined the measurement error and performance-intensity function for the Hearing in Noise Test with normal hearing individuals listening to stimuli processed with the various HRTFs. Experiment 3 compared normal hearing listeners’ performance across HRTFs to determine how the HRTFs affected performance. Experiment 4 evaluated binaural benefits for normal hearing listeners using the various HRTFs, including ones that were modified to investigate the contributions of interaural time and level cues. Results The results indicated that the HRTFs adequately simulated sound field testing for the Hearing in Noise Test. They also demonstrated that the test-retest reliability and performance-intensity function were consistent across HRTFs, and that the measurement error for the test was 1.3 dB, with a change in signal-to-noise ratio of 1 dB reflecting a 10% change in intelligibility. There were significant differences in performance when using the various HRTFs, with particularly good thresholds for the HRTF based on the

  5. The development of auditory skills in young children with Mondini dysplasia after cochlear implantation.

    Directory of Open Access Journals (Sweden)

    Xueqing Chen

    Full Text Available The aim of this study is to survey and compare the development of auditory skills in young children with Mondini dysplasia and profoundly-deaf young children with radiologically normal inner ears over a period of 3 years after cochlear implantation. A total of 545 young children (age 7 to 36 months with prelingual, severe to profound hearing loss participated in this study. All children received cochlear implantation. Based on whether or not there was a Mondini dysplasia as diagnosed with CT scanning, the subjects were divided into 2 groups: (A 514 young children with radiologically normal inner ears and (B 31 young children with Mondini dysplasia. The Infant-Toddler Meaningful Auditory Integration Scale (IT-MAIS was used to assess the children's auditory skills that include vocalization changes, spontaneous alerting to sounds in everyday living environments, and the ability to derive meaning from sounds. The assessment was performed prior to surgery and at 1, 3, 6, 9, 12, 24, and 36 months after implant device switch-on. The mean scores for overall auditory skills were not significantly different between groups A and B at pre-surgery, 1, 12, 24, and 36 months post-surgery, but were significantly different at 3, 6, and 9 months post-surgery. The mean scores for all auditory skills in children with Mondini dysplasia showed significant improvement over time. The mean scores for the three subcategories of auditory skills in children with Mondini dysplasia also showed significant differences at pre-surgery, 1, 3, 6, and 9 months, however, there were no significant differences at 12, 24, and 36 months. Overall, the auditory skills of young children with Mondini dysplasia developed rapidly after cochlear implantation, in a similar manner to that of young children with radiologically normal inner ears. Cochlear implantation is an effective intervention for young children with Mondini dysplasia.

  6. Auditory brainstem activity and development evoked by apical versus basal cochlear implant electrode stimulation in children.

    Science.gov (United States)

    Gordon, K A; Papsin, B C; Harrison, R V

    2007-08-01

    The role of apical versus basal cochlear implant electrode stimulation on central auditory development was examined. We hypothesized that, in children with early onset deafness, auditory development evoked by basal electrode stimulation would differ from that evoked more apically. Responses of the auditory nerve and brainstem, evoked by an apical and a basal implant electrode, were measured over the first year of cochlear implant use in 50 children with early onset severe to profound deafness who used hearing aids prior to implantation. Responses at initial stimulation were of larger amplitude and shorter latency when evoked by the apical electrode. No significant effects of residual hearing or age were found on initial response amplitudes or latencies. With implant use, responses evoked by both electrodes showed decreases in wave and interwave latencies reflecting decreased neural conduction time through the brainstem. Apical versus basal differences persisted with implant experience with one exception; eIII-eV interlatency differences decreased with implant use. Acute stimulation shows prolongation of basally versus apically evoked auditory nerve and brainstem responses in children with severe to profound deafness. Interwave latencies reflecting neural conduction along the caudal and rostral portions of the brainstem decreased over the first year of implant use. Differences in neural conduction times evoked by apical versus basal electrode stimulation persisted in the caudal but not rostral brainstem. Activity-dependent changes of the auditory brainstem occur in response to both apical and basal cochlear implant electrode stimulation.

  7. Identification and Multiplicity of Double Vowels in Cochlear Implant Users

    Science.gov (United States)

    Kwon, Bomjun J.; Perry, Trevor T.

    2014-01-01

    Purpose: The present study examined cochlear implant (CI) users' perception of vowels presented concurrently (i.e., "double vowels") to further our understanding of auditory grouping in electric hearing. Method: Identification of double vowels and single vowels was measured with 10 CI subjects. Fundamental frequencies (F0s) of…

  8. Impedance and electrically evoked compound action potential (ECAP drop within 24 hours after cochlear implantation.

    Directory of Open Access Journals (Sweden)

    Joshua Kuang-Chao Chen

    Full Text Available Previous animal study revealed that post-implantation electrical detection levels significantly declined within days. The impact of cochlear implant (CI insertion on human auditory pathway in terms of impedance and electrically evoked compound action potential (ECAP variation within hours after surgery remains unclear, since at this time frequency mapping can only commence weeks after implantation due to factors associated with wound conditions. The study presented our experiences with regards to initial switch-on within 24 hours, and thus the findings about the milieus inside cochlea within the first few hours after cochlear implantation in terms of impedance/ECAP fluctuations. The charts of fifty-four subjects with profound hearing impairment were studied. A minimal invasive approach was used for cochlear implantation, characterized by a small skin incision (≈ 2.5 cm and soft techniques for cochleostomy. Impedance/ECAP was measured intro-operatively and within 24 hours post-operatively. Initial mapping within 24 hours post-operatively was performed in all patients without major complications. Impedance/ECAP became significantly lower measured within 24 hours post-operatively as compared with intra-operatively (p<0.001. There were no differences between pre-operative and post-operative threshold for air-conduction hearing. A significant drop of impedance/ECAP in one day after cochlear implantation was revealed for the first time in human beings. Mechanisms could be related to the restoration of neuronal sensitivity to the electrical stimulation, and/or the interaction between the matrix enveloping the electrodes and the electrical stimulation of the initial switch-on. Less wound pain/swelling and soft techniques both contributed to the success of immediate initial mapping, which implied a stable micro-environment inside the cochlea despite electrodes insertion. Our research invites further studies to correlate initial impedance/ECAP changes

  9. International survey of cochlear implant candidacy.

    Science.gov (United States)

    Vickers, D; De Raeve, L; Graham, J

    2016-04-01

    The goal of this work was to determine international differences in candidacy based on audiometric and speech perception measures, and to evaluate the information in light of the funding structure and access to implants within different countries. An online questionnaire was circulated to professionals in 25 countries. There were 28 respondents, representing the candidacy practice in 17 countries. Results showed differences in the funding model between countries. Unilateral implants for both adults and children and bilateral implants for children were covered by national funding in approximately 60% of countries (30% used medical insurance, and 10% self-funding). Fewer countries provided bilateral implants routinely for adults: national funding was available in only 22% (37% used medical insurance and 41% self-funding). Main evolving candidacy areas are asymmetric losses, auditory neuropathy spectrum disorders and electro-acoustic stimulation. For countries using speech-based adult candidacy assessments, the majority (40%) used word tests, 24% used sentence tests, and 36% used a mixture of both. For countries using audiometry for candidacy (70-80% of countries), the majority used levels of 75-85 dB HL at frequencies above 1 kHz. The United Kingdom and Belgium had the most conservative audiometric criteria, and countries such as Australia, Germany, and Italy were the most lenient. Countries with a purely self-funding model had greater flexibility in candidacy requirements.

  10. The Suprameatal Approach: A Safe Alternative Surgical Technique for Cochlear Implantation

    NARCIS (Netherlands)

    Postelmans, Job T. F.; Tange, Rinze A.; Stokroos, Robert J.; Grolman, Wilko

    2010-01-01

    Objective: To report on surgical complications arising post-operatively in 104 patients undergoing cochlear implantation surgery using the suprameatal approach (SMA). Second, to examine the advantages and disadvantages of the SMA technique compared with the classic mastoidectomy using the posterior

  11. Cochlear implant-related three-dimensional characteristics determined by micro-computed tomography reconstruction.

    Science.gov (United States)

    Ni, Yusu; Dai, Peidong; Dai, Chunfu; Li, Huawei

    2017-01-01

    To explore the structural characteristics of the cochlea in three-dimensional (3D) detail using 3D micro-computed tomography (mCT) image reconstruction of the osseous labyrinth, with the aim of improving the structural design of electrodes, the selection of stimulation sites, and the effectiveness of cochlear implantation. Three temporal bones were selected from among adult donors' temporal bone specimens. A micro-CT apparatus (GE eXplore) was used to scan three specimens with a voxel resolution of 45 μm. We obtained about 460 slices/specimen, which produced abundant data. The osseous labyrinth images of three specimens were reconstructed from mCT. The cochlea and its spiral characteristics were measured precisely using Able Software 3D-DOCTOR. The 3D images of the osseous labyrinth, including the cochlea, vestibule, and semicircular canals, were reconstructed. The 3D models of the cochlea showed the spatial relationships and surface structural characteristics. Quantitative data concerning the cochlea and its spiral structural characteristics were analyzed with regard to cochlear implantation. The 3D reconstruction of mCT images clearly displayed the detailed spiral structural characteristics of the osseous labyrinth. Quantitative data regarding the cochlea and its spiral structural characteristics could help to improve electrode structural design, signal processing, and the effectiveness of cochlear implantation. Clin. Anat. 30:39-43, 2017. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  12. Development of a multichannel vestibular prosthesis prototype by modification of a commercially available cochlear implant.

    Science.gov (United States)

    Valentin, Nicolas S; Hageman, Kristin N; Dai, Chenkai; Della Santina, Charles C; Fridman, Gene Y

    2013-09-01

    No adequate treatment exists for individuals who remain disabled by bilateral loss of vestibular (inner ear inertial) sensation despite rehabilitation. We have restored vestibular reflexes using lab-built multichannel vestibular prostheses (MVPs) in animals, but translation to clinical practice may be best accomplished by modification of a commercially available cochlear implant (CI). In this interim report, we describe preliminary efforts toward that goal. We developed software and circuitry to sense head rotation and drive a CI's implanted stimulator (IS) to deliver up to 1 K pulses/s via nine electrodes implanted near vestibular nerve branches. Studies in two rhesus monkeys using the modified CI revealed in vivo performance similar to our existing dedicated MVPs. A key focus of our study was the head-worn unit (HWU), which magnetically couples across the scalp to the IS. The HWU must remain securely fixed to the skull to faithfully sense head motion and maintain continuous stimulation. We measured normal and shear force thresholds at which HWU-IS decoupling occurred as a function of scalp thickness and calculated pressure exerted on the scalp. The HWU remained attached for human scalp thicknesses from 3-7.8 mm for forces experienced during routine daily activities, while pressure on the scalp remained below capillary perfusion pressure.

  13. Cochlear Implant: the complexity involved in the decision making process by the family1

    Science.gov (United States)

    Vieira, Sheila de Souza; Bevilacqua, Maria Cecília; Ferreira, Noeli Marchioro Liston Andrade; Dupas, Giselle

    2014-01-01

    Objective to understand the meanings the family attributes to the phases of the decision-making process on a cochlear implant for their child. Method qualitative research, using Symbolic Interactionism and Grounded Theory as the theoretical and methodological frameworks, respectively. Data collection instrument: semistructured interview. Nine families participated in the study (32 participants). Results knowledge deficit, difficulties to contextualize benefits and risks and fear are some factors that make this process difficult. Experiences deriving from interactions with health professionals, other cochlear implant users and their relatives strengthen decision making in favor of the implant. Conclusion deciding on whether or not to have the implant involves a complex process, in which the family needs to weigh gains and losses, experience feelings of accountability and guilt, besides overcoming the risk aversion. Hence, this demands cautious preparation and knowledge from the professionals involved in this intervention. PMID:25029052

  14. A Systematic Review to Define the Speech and Language Benefit of Early (<12 Months) Pediatric Cochlear Implantation.

    Science.gov (United States)

    Bruijnzeel, Hanneke; Ziylan, Fuat; Stegeman, Inge; Topsakal, Vedat; Grolman, Wilko

    2016-01-01

    This review aimed to evaluate the additional benefit of pediatric cochlear implantation before 12 months of age considering improved speech and language development and auditory performance. We conducted a search in PubMed, EMBASE and CINAHL databases and included studies comparing groups with different ages at implantation and assessing speech perception and speech production, receptive language and/or auditory performance. We included studies with a high directness of evidence (DoE). We retrieved 3,360 articles. Ten studies with a high DoE were included. Four articles with medium DoE were discussed in addition. Six studies compared infants implanted before 12 months with children implanted between 12 and 24 months. Follow-up ranged from 6 months to 9 years. Cochlear implantation before the age of 2 years is beneficial according to one speech perception score (phonetically balanced kindergarten combined with consonant-nucleus-consonant) but not on Glendonald auditory screening procedure scores. Implantation before 12 months resulted in better speech production (diagnostic evaluation of articulation and phonology and infant-toddler meaningful auditory integration scale), auditory performance (Categories of Auditory Performance-II score) and receptive language scores (2 out of 5; Preschool Language Scale combined with oral and written language skills and Peabody Picture Vocabulary Test). The current best evidence lacks level 1 evidence studies and consists mainly of cohort studies with a moderate to high risk of bias. Included studies showed consistent evidence that cochlear implantation should be performed early in life, but evidence is inconsistent on all speech and language outcome measures regarding the additional benefit of implantation before the age of 12 months. Long-term follow-up studies are necessary to provide insight on additional benefits of early pediatric cochlear implantation. © 2016 S. Karger AG, Basel.

  15. Music perception and appraisal: cochlear implant users and simulated cochlear implant listening.

    Science.gov (United States)

    Wright, Rose; Uchanski, Rosalie M

    2012-05-01

    The inability to hear music well may contribute to decreased quality of life for cochlear implant (CI) users. Researchers have reported recently on the generally poor ability of CI users to perceive music, and a few researchers have reported on the enjoyment of music by CI users. However, the relation between music perception skills and music enjoyment is much less explored. Only one study has attempted to predict CI users' enjoyment and perception of music from the users' demographic variables and other perceptual skills (Gfeller et al, 2008). Gfeller's results yielded different predictive relationships for music perception and music enjoyment, and the relationships were weak, at best. The first goal of this study is to clarify the nature and relationship between music perception skills and musical enjoyment for CI users, by employing a battery of music tests. The second goal is to determine whether normal hearing (NH) subjects, listening with a CI simulation, can be used as a model to represent actual CI users for either music enjoyment ratings or music perception tasks. A prospective, cross-sectional observational study. Original music stimuli (unprocessed) were presented to CI users, and music stimuli processed with CI-simulation software were presented to 20 NH listeners (CIsim). As a control, original music stimuli were also presented to five other NH listeners. All listeners appraised 24 musical excerpts, performed music perception tests, and filled out a musical background questionnaire. Music perception tests were the Appreciation of Music in Cochlear Implantees (AMICI), Montreal Battery for Evaluation of Amusia (MBEA), Melodic Contour Identification (MCI), and University of Washington Clinical Assessment of Music Perception (UW-CAMP). Twenty-five NH adults (22-56 yr old), recruited from the local and research communities, participated in the study. Ten adult CI users (46-80 yr old), recruited from the patient population of the local adult cochlear implant

  16. Surgical Results and Complications of Cochlear Implantation in Far-Advanced Otosclerosis

    DEFF Research Database (Denmark)

    West, Niels; Brand, Markus; Foghsgaard, Søren

    2017-01-01

    OBJECTIVE: To report surgical results and complications of cochlear implantation in patients with far-advanced otosclerosis (FAO). MATERIALS AND METHODS: This was a retrospective chart review of surgical results in terms of electrode insertion as well as peri- and postoperative complications. Ten...

  17. Revision surgery due to magnet dislocation in cochlear implant patients: an emerging complication.

    Science.gov (United States)

    Hassepass, Frederike; Stabenau, Vanessa; Maier, Wolfgang; Arndt, Susan; Laszig, Roland; Beck, Rainer; Aschendorff, Antje

    2014-01-01

    To analyze the cause and effect of magnet dislocation in cochlear implant (CI) recipients requiring magnet revision surgery for treatment. Retrospective study. Tertiary referral center. Case reports from 1,706 CI recipients consecutively implanted from January 2000 to December 2011 were reviewed. The number of cases requiring magnet revision surgery was assessed. Revision surgery involving magnet removal or replacement was indicated in 1.23% (21/1,706), of all CI recipients. Magnet dislocation occurring during magnetic resonance tomography (MRI), at 1.5 Tesla (T), with the magnet in place and with the application of compression bandaging around the head, was the main cause for revision surgery in 47.62% (10/21) of the affected cases. All 10 cases were implanted with Cochlear Nucleus cochlear implants. These events occurred, despite adherence to current recommendations of the manufacturer. The present study underlines that MRI examination is the main cause of magnet dislocation. The use of compressive bandaging when using 1.5-T MRI does not eliminate the risk of magnet dislocation. Additional cautionary measures are for required for conditional MRI. We recommend X-ray examination after MRI to determine magnet dislocation and avoid major complications in all cases reporting pain during or after MRI. Additional research regarding silicon magnet pocket design for added retention is needed. Effective communication of guidelines for precautionary measures during MRI examination in CI patients is mandatory for all clinicians involved. MRI in CI recipients should be indicated with caution.

  18. Rehabilitation of deaf persons with cochlear implants; Rehabilitation Hoergeschaedigter mit Cochlearimplantaten

    Energy Technology Data Exchange (ETDEWEB)

    Gstoettner, W.; Hamzavi, J. [Universitaetsklinik fuer Hals-Nasen-Ohrenheilkunde, Wien (Austria); Czerny, C. [Universitaetsklinik fuer Radiologie, Wien (Austria)

    1997-12-01

    In the last decade, the rehabilitation of postlingually deaf adults and prelingually deaf children with cochlear implants has been established as a treatment of deafness. The technological development of the implant devices and improvement of the surgical technique have led to a considerable increase of hearing performance during the last years. The postlingually deaf adults are able to use the telephone and may be integrated in their original job. Prelingually deaf children can even visit normal schools after cochlear implantation and hearing rehabilitation training. In order to preoperatively establish the state of the cochlear, radiological diagnosis of the temporal bone is necessary. High resolution computerized tomography imaging of the temporal bone with coronar and axial 1 mm slices and MRI with thin slice technique (three dimensional, T2 weighted turbo-spinecho sequence with 0.7 mm slices) have proved to be valuable according to our experience. Furthermore a postoperative synoptical X-ray, in a modified Chausse III projection, offers good information about the position of the implant and insertion of the stimulating electrode into the cochlea. (orig.) [Deutsch] In der letzten Dekade hat sich der operative Einsatz von Cochlearimplantaten fuer die Rehabilitation taubgeborener Kinder und ertaubter Erwachsenen als erfolgreiche Therapie etabliert. Durch technische Weiterentwicklung der Implantatsysteme und Verbesserung der Operationstechnik konnten in den letzten Jahren die Hoerleistungen der Patienten deutlich verbessert werden. Postlingual ertaubte Erwachsene koennen nun oftmals wieder ins Berufsleben eingegliedert werden und praelingual ertaubte Kinder koennen regulaere Schulen besuchen. Im Rahmen der Voruntersuchung fuer die Cochlearimplantation ist die radiologische Felsenbeindiagnostik von besonderer Bedeutung. Hochaufloesendes CT des Felsenbeins in koronaren und axialen Ebenen mit 1 mm Schichtdicke und MRT in Duennschichttechnik (dreidimensionale, T2

  19. Age or experience? The influence of age at implantation and social and linguistic environment on language development in children with cochlear implants.

    Science.gov (United States)

    Szagun, Gisela; Stumper, Barbara

    2012-12-01

    The authors investigated the influence of social environmental variables and age at implantation on language development in children with cochlear implants. Participants were 25 children with cochlear implants and their parents. Age at implantation ranged from 6 months to 42 months ( M (age) = 20.4 months, SD = 22.0 months). Linguistic progress was assessed at 12, 18, 24, and 30 months after implantation. At each data point, language measures were based on parental questionnaire and 45-min spontaneous speech samples. Children's language and parents' child-directed language were analyzed. On all language measures, children displayed considerable vocabulary and grammatical growth over time. Although there was no overall effect of age at implantation, younger and older children had different growth patterns. Children implanted by age 24 months made the most marked progress earlier on, whereas children implanted thereafter did so later on. Higher levels of maternal education were associated with faster linguistic progress; age at implantation was not. Properties of maternal language input, mean length of utterance, and expansions were associated with children's linguistic progress independently of age at implantation. In children implanted within the sensitive period for language learning, children's home language environment contributes more crucially to their linguistic progress than does age at implantation.

  20. Expected Test Scores for Preschoolers with a Cochlear Implant Who Use Spoken Language

    Science.gov (United States)

    Nicholas, Johanna G.; Geers, Ann E.

    2008-01-01

    Purpose: The major purpose of this study was to provide information about expected spoken language skills of preschool-age children who are deaf and who use a cochlear implant. A goal was to provide "benchmarks" against which those skills could be compared, for a given age at implantation. We also examined whether parent-completed…

  1. [The evolution of surgical interventions for cochlear implantation at the Russian Research and Practical Centre of Audiology and Hearing Rehabilitation].

    Science.gov (United States)

    Fedoseev, V I; Dmitriev, N S

    2014-01-01

    The objective of the present study was to estimate and analyse the effectiveness and labour intensity of the methods of surgical intervention for cochlear implantation. The analysis of the surgical stage of cochlear implantation was based on the examination of 2073 children and adults during the period from 1991 to 2013. The age of the patients varied between 6 months to 71 years. The cause of deafness was meningitis and an injury in 11% and 6% of the patients respectively. The cochlear implants from Advanced Bionics were inserted in 495 patients, those from Med-El in 9 ones , and from Neurelec in 20, and Nucleus devices from Cochlear in the remaining patents (n=1549) including 37 double-array electrodes and a Hybrid implant for electroacoustic correction of hearing . The implants with a straight and perimodiolar electrode were placed in a roughly equal number of the patients. The rationale for the performance of selected components of the surgical stage of cochlear implantation was developed along with the technical procedures for the purpose applied at this Centre since 1991. The original methods for the fixation and covering of the receiver-stimulator and also for the choice of the place of the electrode array insertion into the cochlea are described. They allowed to significantly decrease the frequency of complications, duration and extent of the surgical intervention as well as to reduce to a minimum post-operative manipulations.

  2. In-vitro characterization of a cochlear implant system for recording of evoked compound action potentials

    Science.gov (United States)

    2012-01-01

    Background Modern cochlear implants have integrated recording systems for measuring electrically evoked compound action potentials of the auditory nerve. The characterization of such recording systems is important for establishing a reliable basis for the interpretation of signals acquired in vivo. In this study we investigated the characteristics of the recording system integrated into the MED-EL PULSARCI100 cochlear implant, especially its linearity and resolution, in order to develop a mathematical model describing the recording system. Methods In-vitro setup: The cochlear implant, including all attached electrodes, was fixed in a tank of physiologic saline solution. Sinusoidal signals of the same frequency but with different amplitudes were delivered via a signal generator for measuring and recording on a single electrode. Computer simulations: A basic mathematical model including the main elements of the recording system, i.e. amplification and digitalization stage, was developed. For this, digital output for sinusoidal input signals of different amplitudes were calculated using in-vitro recordings as reference. Results Using an averaging of 100 measurements the recording system behaved linearly down to approximately -60 dB of the input signal range. Using the same method, a system resolution of 10 μV was determined for sinusoidal signals. The simulation results were in very good agreement with the results obtained from in-vitro experiments. Conclusions The recording system implemented in the MED-EL PULSARCI100 cochlear implant for measuring the evoked compound action potential of the auditory nerve operates reliably. The developed mathematical model provides a good approximation of the recording system. PMID:22531599

  3. Coding strategies for cochlear implants under adverse environments

    Science.gov (United States)

    Tahmina, Qudsia

    Cochlear implants are electronic prosthetic devices that restores partial hearing in patients with severe to profound hearing loss. Although most coding strategies have significantly improved the perception of speech in quite listening conditions, there remains limitations on speech perception under adverse environments such as in background noise, reverberation and band-limited channels, and we propose strategies that improve the intelligibility of speech transmitted over the telephone networks, reverberated speech and speech in the presence of background noise. For telephone processed speech, we propose to examine the effects of adding low-frequency and high- frequency information to the band-limited telephone speech. Four listening conditions were designed to simulate the receiving frequency characteristics of telephone handsets. Results indicated improvement in cochlear implant and bimodal listening when telephone speech was augmented with high frequency information and therefore this study provides support for design of algorithms to extend the bandwidth towards higher frequencies. The results also indicated added benefit from hearing aids for bimodal listeners in all four types of listening conditions. Speech understanding in acoustically reverberant environments is always a difficult task for hearing impaired listeners. Reverberated sounds consists of direct sound, early reflections and late reflections. Late reflections are known to be detrimental to speech intelligibility. In this study, we propose a reverberation suppression strategy based on spectral subtraction to suppress the reverberant energies from late reflections. Results from listening tests for two reverberant conditions (RT60 = 0.3s and 1.0s) indicated significant improvement when stimuli was processed with SS strategy. The proposed strategy operates with little to no prior information on the signal and the room characteristics and therefore, can potentially be implemented in real-time CI

  4. Bilateral Intravitreal Dexamethasone Implant for Retinitis Pigmentosa-Related Macular Edema

    Directory of Open Access Journals (Sweden)

    Ali Osman Saatci

    2013-03-01

    Full Text Available Purpose: To report the efficacy of intravitreal dexamethasone implant in a patient with retinitis pigmentosa and bilateral cystoid macular edema unresponsive to topical carbonic anhydrase inhibitors. Case Report: A 36-year-old man with bilateral cystoid macular edema associated with retinitis pigmentosa that was unresponsive to topical carbonic anhydrase inhibitors underwent bilateral 0.7-mg intravitreal dexamethasone implants two weeks apart. Spectral domain optical coherence tomography revealed resolution of macular edema one week following each injection in both eyes and his visual acuity improved. However, macular edema recurred two months later in OS and three months later in OD. Second implant was considered for both eyes. No implant-related complication was experienced during the follow-up of seven months. Conclusion: Inflammatory process seems to play a role in retinitis pigmentosa. Intravitreal dexamethasone implant may offer retina specialists a therapeutic option especially in cases unresponsive to other treatment regimens in eyes with retinitis pigmentosa-related macular edema.

  5. Suppression of Tinnitus in Chinese Patients Receiving Regular Cochlear Implant Programming.

    Science.gov (United States)

    Liu, Ying; Wang, Hong; Han, Dong Xu; Li, Ming Hua; Wang, Yu; Xiao, Yu Li

    2016-04-01

    To assess the clinical effect of cochlear implant programming on tinnitus. Tinnitus patients (n = 234) were divided into 3 groups: (1) preoperative tinnitus (n = 108), (2) postoperative tinnitus occurring before implant switch-on at week 4 (n = 88), and (3) tinnitus occurring more than 1 year postoperatively (n = 44). Patients in each group were randomly allocated into a programming subgroup that received programming for 12 weeks postoperatively or after tinnitus occurrence or a control subgroup. Impedance testing and the Tinnitus Handicap Inventory (THI) were performed preoperatively and at 4, 6, 8, and 12 weeks postoperatively (groups 1 and 2) or after tinnitus occurrence (group 3). Comparisons were performed using t tests and chi-square tests. Impedance was significantly lower in the programming subgroup than in the control subgroup in groups 1 and 2 at 8 and 12 weeks and in group 3 at 12 weeks. The THI scores decreased in both programming and control subgroups in all groups. However, this decrease was pronounced in the programming subgroup, whereas in the control subgroup, it occurred slowly over time. Cochlear implant programming decreases impedance and improves tinnitus symptoms. © The Author(s) 2015.

  6. Systematic review of compound action potentials as predictors for cochlear implant performance

    NARCIS (Netherlands)

    van Eijl, Ruben H M; Buitenhuis, Patrick J.; Stegeman, Inge; Klis, Sjaak F L; Grolman, Wilko

    2017-01-01

    Objectives/Hypothesis: The variability in speech perception between cochlear implant users is thought to result from the degeneration of the auditory nerve. Degeneration of the auditory nerve, histologically assessed, correlates with electrophysiologically acquired measures, such as electrically

  7. Speech Recognition and Cognitive Skills in Bimodal Cochlear Implant Users

    Science.gov (United States)

    Hua, Håkan; Johansson, Björn; Magnusson, Lennart; Lyxell, Björn; Ellis, Rachel J.

    2017-01-01

    Purpose: To examine the relation between speech recognition and cognitive skills in bimodal cochlear implant (CI) and hearing aid users. Method: Seventeen bimodal CI users (28-74 years) were recruited to the study. Speech recognition tests were carried out in quiet and in noise. The cognitive tests employed included the Reading Span Test and the…

  8. Deaf Parents of Cochlear-Implanted Children: Beliefs on Bimodal Bilingualism

    Science.gov (United States)

    Mitchiner, Julie Cantrell

    2015-01-01

    This study investigated 17 Deaf families in North America with cochlear-implanted children about their attitudes, beliefs, and practices on bimodal bilingualism (defined as using both a visual/manual language and an aural/oral language) in American Sign Language (ASL) and English. A survey and follow-up interviews with 8 families were conducted.…

  9. Effects of maternal sensitivity and cognitive and linguistic stimulation on cochlear implant users' language development over four years.

    Science.gov (United States)

    Quittner, Alexandra L; Cruz, Ivette; Barker, David H; Tobey, Emily; Eisenberg, Laurie S; Niparko, John K

    2013-02-01

    To examine the effects of observed maternal sensitivity (MS), cognitive stimulation (CS), and linguistic stimulation on the 4-year growth of oral language in young, deaf children receiving a cochlear implant. Previous studies of cochlear implants have not considered the effects of parental behaviors on language outcomes. In this prospective, multisite study, we evaluated parent-child interactions during structured and unstructured play tasks and their effects on oral language development in 188 deaf children receiving a cochlear implant and 97 normal-hearing children as controls. Parent-child interactions were rated on a 7-point scale using the National Institute of Child Health and Human Development's Early Childcare Study codes, which have well-established psychometric properties. Language was assessed using the MacArthur Bates Communicative Development Inventories, the Reynell Developmental Language Scales, and the Comprehensive Assessment of Spoken Language. We used mixed longitudinal modeling to test our hypotheses. After accounting for early hearing experience and child and family demographics, MS and CS predicted significant increases in the growth of oral language. Linguistic stimulation was related to language growth only in the context of high MS. The magnitude of effects of MS and CS on the growth of language was similar to that found for age at cochlear implantation, suggesting that addressing parenting behaviors is a critical target for early language learning after implantation. Copyright © 2013 Mosby, Inc. All rights reserved.

  10. A two-microphone noise reduction system for cochlear implant users with nearby microphones. Part II: Performance Evaluation

    OpenAIRE

    Kompis, Martin; Bertram, Matthias; Senn, Pascal; Müller, Joachim; Pelizzone, Marco; Häusler, Rudolf

    2008-01-01

    Users of cochlear implants (auditory aids, which stimulate the auditory nerve electrically at the inner ear) often suffer from poor speech understanding in noise. We evaluate a small (intermicrophone distance 7 mm) and computationally inexpensive adaptive noise reduction system suitable for behind-the-ear cochlear implant speech processors. The system is evaluated in simulated and real, anechoic and reverberant environments. Results from simulations show improvements of 3.4 to 9.3 dB in signa...

  11. Bilateral Changes of Spontaneous Activity Within the Central Auditory Pathway Upon Chronic Unilateral Intracochlear Electrical Stimulation.

    Science.gov (United States)

    Basta, Dietmar; Götze, Romy; Gröschel, Moritz; Jansen, Sebastian; Janke, Oliver; Tzschentke, Barbara; Boyle, Patrick; Ernst, Arne

    2015-12-01

    In recent years, cochlear implants have been applied successfully for the treatment of unilateral hearing loss with quite surprising benefit. One reason for this successful treatment, including the relief from tinnitus, could be the normalization of spontaneous activity in the central auditory pathway because of the electrical stimulation. The present study, therefore, investigated at a cellular level, the effect of a unilateral chronic intracochlear stimulation on key structures of the central auditory pathway. Normal-hearing guinea pigs were mechanically single-sided deafened through a standard HiFocus1j electrode array (on a HiRes 90k cochlear implant) being inserted into the first turn of the cochlea. Four to five electrode contacts could be used for the stimulation. Six weeks after surgery, the speech processor (Auria) was fitted, based on tNRI values and mounted on the animal's back. The two experimental groups were stimulated 16 hours per day for 90 days, using a HiRes strategy based on different stimulation rates (low rate (275 pps/ch), high rate (5000 pps/ch)). The results were compared with those of unilateral deafened controls (implanted but not stimulated), as well as between the treatment groups. All animals experienced a standardized free field auditory environment. The low-rate group showed a significantly lower average spontaneous activity bilaterally in the dorsal cochlear nucleus and the medial geniculate body than the controls. However, there was no difference in the inferior colliculus and the primary auditory cortex. Spontaneous activity of the high-rate group was also reduced bilaterally in the dorsal cochlear nucleus and in the primary auditory cortex. No differences could be observed between the high-rate group and the controls in the contra-lateral inferior colliculus and medial geniculate body. The high-rate group showed bilaterally a higher activity in the CN and the MGB compared with the low-rate group, whereas in the IC and in the

  12. Challenging aspects of contemporary cochlear implant electrode array design.

    Science.gov (United States)

    Mistrík, Pavel; Jolly, Claude; Sieber, Daniel; Hochmair, Ingeborg

    2017-12-01

    A design comparison of current perimodiolar and lateral wall electrode arrays of the cochlear implant (CI) is provided. The focus is on functional features such as acoustic frequency coverage and tonotopic mapping, battery consumption and dynamic range. A traumacity of their insertion is also evaluated. Review of up-to-date literature. Perimodiolar electrode arrays are positioned in the basal turn of the cochlea near the modiolus. They are designed to initiate the action potential in the proximity to the neural soma located in spiral ganglion. On the other hand, lateral wall electrode arrays can be inserted deeper inside the cochlea, as they are located along the lateral wall and such insertion trajectory is less traumatic. This class of arrays targets primarily surviving neural peripheral processes. Due to their larger insertion depth, lateral wall arrays can deliver lower acoustic frequencies in manner better corresponding to cochlear tonotopicity. In fact, spiral ganglion sections containing auditory nerve fibres tuned to low acoustic frequencies are located deeper than 1 and half turn inside the cochlea. For this reason, a significant frequency mismatch might be occurring for apical electrodes in perimodiolar arrays, detrimental to speech perception. Tonal languages such as Mandarin might be therefore better treated with lateral wall arrays. On the other hand, closer proximity to target tissue results in lower psychophysical threshold levels for perimodiolar arrays. However, the maximal comfort level is also lower, paradoxically resulting in narrower dynamic range than that of lateral wall arrays. Battery consumption is comparable for both types of arrays. Lateral wall arrays are less likely to cause trauma to cochlear structures. As the current trend in cochlear implantation is the maximal protection of residual acoustic hearing, the lateral wall arrays seem more suitable for hearing preservation CI surgeries. Future development could focus on combining the

  13. Facilitating Vocabulary Acquisition of Children With Cochlear Implants Using Electronic Storybooks.

    Science.gov (United States)

    Messier, Jane; Wood, Carla

    2015-10-01

    The present intervention study explored the word learning of 18 children with cochlear implants in response to E-book instruction. Capitalizing on the multimedia options available in electronic storybooks, the intervention incorporated videos and definitions to provide a vocabulary intervention that includes evidence-based teaching strategies. The extent of the children's word learning was assessed using three assessment tasks: receptive pointing, expressively labeling, and word defining. Children demonstrated greater immediate expressive labeling gains and definition generation gains for words taught in the treatment condition compared to those in the comparison condition. In addition, the children's performance on delayed posttest vocabulary assessments indicated better retention across the expressive vocabulary task for words taught within the treatment condition as compared to the comparison condition. Findings suggest that children with cochlear implants with functional speech perception can benefit from an oral-only multimedia-enhanced intensive vocabulary instruction. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  14. Speech perception after cochlear implantation in 53 patients with otosclerosis: multicentre results.

    NARCIS (Netherlands)

    Rotteveel, L.J.C.; Snik, A.F.M.; Cooper, H.; Mawman, D.J.; Olphen, A.F. van; Mylanus, E.A.M.

    2010-01-01

    OBJECTIVES: To analyse the speech perception performance of 53 cochlear implant recipients with otosclerosis and to evaluate which factors influenced patient performance in this group. The factors included disease-related data such as demographics, pre-operative audiological characteristics, the

  15. The Acceptance of Background Noise in Adult Cochlear Implant Users

    Science.gov (United States)

    Plyler, Patrick N.; Bahng, Junghwa; von Hapsburg, Deborah

    2008-01-01

    Purpose: The purpose of this study was to determine (a) if acceptable noise levels (ANLs) are different in cochlear implant (CI) users than in listeners with normal hearing, (b) if ANLs are related to sentence reception thresholds in noise in CI users, and (c) if ANLs and subjective outcome measures are related in CI users. Method: ANLs and the…

  16. Perception of Cantonese Lexical Tones by Pediatric Cochlear Implant Users

    Science.gov (United States)

    Holt, Colleen M.; Lee, Kathy Y. S.; Dowell, Richard C.; Vogel, Adam P.

    2018-01-01

    Purpose: The purpose of this study is to assess Cantonese word recognition and the discrimination of Cantonese tones with manipulated contours by child and adolescent cochlear implant (CI) users and a group of peers with normal hearing (NH). It was hypothesized that the CI users would perform more poorly than their counterparts with NH in both…

  17. Factors Affecting Daily Cochlear Implant Use in Children: Datalogging Evidence.

    Science.gov (United States)

    Easwar, Vijayalakshmi; Sanfilippo, Joseph; Papsin, Blake; Gordon, Karen

    Children with profound hearing loss can gain access to sound through cochlear implants (CIs), but these devices must be worn consistently to promote auditory development. Although subjective parent reports have identified several factors limiting long-term CI use in children, it is also important to understand the day-to-day issues which may preclude consistent device use. In the present study, objective measures gathered through datalogging software were used to quantify the following in children: (1) number of hours of CI use per day, (2) practical concerns including repeated disconnections between the external transmission coil and the internal device (termed "coil-offs"), and (3) listening environments experienced during daily use. This study aimed to (1) objectively measure daily CI use and factors influencing consistent device use in children using one or two CIs and (2) evaluate the intensity levels and types of listening environments children are exposed to during daily CI use. Retrospective analysis. Measures of daily CI use were obtained from 146 pediatric users of Cochlear Nucleus 6 speech processors. The sample included 5 unilateral, 40 bimodal, and 101 bilateral CI users (77 simultaneously and 24 sequentially implanted). Daily CI use, duration, and frequency of coil-offs per day, and the time spent in multiple intensity ranges and environment types were extracted from the datalog saved during clinic appointments. Multiple regression analyses were completed to predict daily CI use based on child-related demographic variables, and to evaluate the effects of age on coil-offs and environment acoustics. Children used their CIs for 9.86 ± 3.43 hr on average on a daily basis, with use exceeding 9 hr per day in ∼64% of the children. Daily CI use reduced significantly with increasing durations of coil-off (p = 0.027) and increased significantly with longer CI experience (p Listening environments of all children typically ranged between 50 and 70 d

  18. Bilateral Poly Implant Prothèse Implant Rupture: An Uncommon Presentation

    Directory of Open Access Journals (Sweden)

    Peter Mallon

    2013-07-01

    Full Text Available Summary: A woman in her 50s underwent delayed bilateral Poly Implant Prothèse implant reconstruction following mastectomy for breast cancer. Symptoms of implant rupture developed 43 months after surgery with an erythematous rash on her trunk. The rash then spread to her reconstructed breast mounds. Initial ultrasound scan and magnetic resonance imaging were normal; however, subsequent magnetic resonance imaging demonstrated left implant rupture only. In theater, following removal of both implants, both were found to be ruptured. The rash on her trunk resolved within 3 weeks in the postoperative period. Chemical analyses of silicone in both implants confirmed a nonauthorized silicone source; in addition, the chemical structure was significantly different between the left and right implant, perhaps explaining the variation in presentation.

  19. Beyond hearing : social-emotional outcomes following cochlear implantation in young children

    NARCIS (Netherlands)

    Ketelaar, Lizet

    2014-01-01

    In comparison to hearing children, children with hearing loss more often experience social-emotional problems. This thesis aimed to assess whether this was also true for 1-to-5-year-old children who had received a cochlear implant (CI) to remediate their hearing loss. In comparison to hearing peers,

  20. Speech Rate Normalization and Phonemic Boundary Perception in Cochlear-Implant Users

    Science.gov (United States)

    Jaekel, Brittany N.; Newman, Rochelle S.; Goupell, Matthew J.

    2017-01-01

    Purpose: Normal-hearing (NH) listeners rate normalize, temporarily remapping phonemic category boundaries to account for a talker's speech rate. It is unknown if adults who use auditory prostheses called cochlear implants (CI) can rate normalize, as CIs transmit degraded speech signals to the auditory nerve. Ineffective adjustment to rate…

  1. Concept Formation Skills in Long-Term Cochlear Implant Users

    OpenAIRE

    Castellanos, Irina; Kronenberger, William G.; Beer, Jessica; Colson, Bethany G.; Henning, Shirley C.; Ditmars, Allison; Pisoni, David B.

    2014-01-01

    This study investigated if a period of auditory sensory deprivation followed by degraded auditory input and related language delays affects visual concept formation skills in long-term prelingually deaf cochlear implant (CI) users. We also examined if concept formation skills are mediated or moderated by other neurocognitive domains (i.e., language, working memory, and executive control). Relative to normally hearing (NH) peers, CI users displayed significantly poorer performance in several s...

  2. Magnetic Resonance Imaging With Cochlear Implant Magnet in Place: Safety and Imaging Quality.

    Science.gov (United States)

    Carlson, Matthew L; Neff, Brian A; Link, Michael J; Lane, John I; Watson, Robert E; McGee, Kiaran P; Bernstein, Matt A; Driscoll, Colin L W

    2015-07-01

    To evaluate the safety and image quality of 1.5-T MRI in patients with cochlear implants and retained internal magnets. Retrospective case series from 2012 to 2014. Single tertiary academic referral center. All cochlear implant recipients undergoing 1.5-T MRI without internal magnet removal. MRI after tight headwrap application. Patient tolerance, complications, and characteristics of imaging artifact. Nineteen ears underwent a total of 34 MRI scans. Two patients did not tolerate imaging with the headwrap in place and required magnet removal before rescanning. One subject experienced two separate episodes of polarity reversal in the same device from physical realignment (i.e., flipping) of the internal magnet requiring surgical repositioning. Three patients were discovered to have canting of the internal magnet after imaging. In all three cases, the magnet could be reseated by applying gentle firm pressure to the scalp until the magnet "popped" back into place. These patients continue to use their device without difficulty and have not required surgical replacement. In patients receiving head MRI, the ipsilateral internal auditory canal and cerebellopontine angle could be visualized without difficulty in 94% of cases. There were no episodes of cochlear implant device failure or soft tissue complications. Under controlled conditions, 1.5-T MRI can be successfully performed in most patients without the need for cochlear implant magnet removal. In nearly all cases, imaging artifact does not impede evaluation of the ipsilateral skull base. Patients should be counseled regarding the risk of internal magnet movement that may occur in up to 15% of cases, even with tight headwrap application. If internal magnet polarity reversal occurs, a trial of reversing the external magnet can be considered. If canting or mild displacement of the internal magnet occurs, an attempt at reseating can be made by applying gentle firm pressure to the scalp over the internal magnet. If

  3. Parental perspectives of children using cochlear implant.

    Science.gov (United States)

    Stefanini, Marcela Roselin; Morettin, Marina; Zabeu, Julia Speranza; Bevilacqua, Maria Cecília; Moret, Adriane Lima Mortari

    2014-01-01

    To evaluate the parents' perspective with regard to evolution of their child with cochlear implant (CI). This was a cross-sectional prospective study conducted at the Centro de Pesquisas Audiológicas of Hospital de Reabilitação de Anomalias Craniofaciais of Universidade de São Paulo. The selection of the sample was performed from the spontaneous demand, among the months from July to December 2011. The final sample comprised 50 parents or guardians of children using CI, with minimum 1 year and maximum of 3 years of device use. The translated and adapted to Brazilian Portuguese version of the questionnaire "Perspectives of parents of children with cochlear implants" was applied. This instrument consists of 74 questions and allows quantification of the parents' perspective on subscales that illustrate the situation of the child and family. Each question has five options scored from one to five responses. The Spearman test for comparison of results between the subscales was applied. The social relationships, self-sufficiency, and communication subscales showed the highest mean score, whereas the worst score was for child support subscale, reflecting the independence and autonomy of the patients. The correlation between the child subscales was realized, and the results showed themselves significant and positive for communication subscale of communication with all others subscales. The family subscales also had a positive correlation with the communication, education, and self-sufficiency. These results demonstrate that parents have good expectations regarding communication, independence, and social participation of children after CI surgery, and this questionnaire is a useful tool for use in clinical practice.

  4. Self- and parental assessment of quality of life in child cochlear implant bearers.

    Science.gov (United States)

    Razafimahefa-Raoelina, T; Farinetti, A; Nicollas, R; Triglia, J-M; Roman, S; Anderson, L

    2016-02-01

    The aim of this study was to assess quality of life in children fitted with cochlear implants, using combined self- and parental assessment. Thirty-two children, aged 6 to 17 years, with prelingual hearing loss and receiving cochlear implants at a mean age of 22 months, were included along with their families. The KIDSCREEN-27 questionnaire was implemented, in face-to-face interview, in its parents and children-adolescents versions, with 27 items covering physical well-being ("physical activities and health"), psychological well-being ("general mood and feelings about yourself"), autonomy & parents ("family and free time"), peers & social support ("friends") and school environment ("school and learning"). Parent and child responses were compared with a general population database, and pairwise. Global scores were compared against the general population on Cohen d effect-size. For child self-assessment, the results were: physical well-being, 72.81 (d=0); psychological well-being, 78.13 (d=-0.4); autonomy & parents, 63.84 (d=-0.2); peers & social support, 61.72 (d=-0.4); and school environment 73.83 (d=0). For parent assessment, the respective results were 62.66 (d=-0.8), 74.89 (d=-0.3), 57.37 (d=-1.2), 51.56 (d=-0.8), and 68.95 (d=-0.4). Half of the children could not answer the questionnaire, mainly due to associated disability. Schooling and language performance were poorer in non-respondent than respondent children. Quality of life was comparable between implanted and non-implanted children: Cohen d, 0 to 0.4. Early cochlear implantation in children with pre-lingual hearting loss provides quality of life comparable to that of the general population. Copyright © 2015. Published by Elsevier Masson SAS.

  5. The Summating Potential Is a Reliable Marker of Electrode Position in Electrocochleography: Cochlear Implant as a Theragnostic Probe.

    Science.gov (United States)

    Helmstaedter, Victor; Lenarz, Thomas; Erfurt, Peter; Kral, Andrej; Baumhoff, Peter

    2017-12-14

    For the increasing number of cochlear implantations in subjects with residual hearing, hearing preservation, and thus the prevention of implantation trauma, is crucial. A method for monitoring the intracochlear position of a cochlear implant (CI) and early indication of imminent cochlear trauma would help to assist the surgeon to achieve this goal. The aim of this study was to evaluate the reliability of the different electric components recorded by an intracochlear electrocochleography (ECochG) as markers for the cochleotopic position of a CI. The measurements were made directly from the CI, combining intrasurgical diagnostics with the therapeutical use of the CI, thus, turning the CI into a "theragnostic probe." Intracochlear ECochGs were measured in 10 Dunkin Hartley guinea pigs of either sex, with normal auditory brainstem response thresholds. All subjects were fully implanted (4 to 5 mm) with a custom six contact CI. The ECochG was recorded simultaneously from all six contacts with monopolar configuration (retroauricular reference electrode). The gross ECochG signal was filtered off-line to separate three of its main components: compound action potential, cochlear microphonic, and summating potential (SP). Additionally, five cochleae were harvested and histologically processed to access the spatial position of the CI contacts. Both ECochG data and histological reconstructions of the electrode position were fitted with the Greenwood function to verify the reliability of the deduced cochleotopic position of the CI. SPs could be used as suitable markers for the frequency position of the recording electrode with an accuracy of ±1/4 octave in the functioning cochlea, verified by histology. Cochlear microphonics showed a dependency on electrode position but were less reliable as positional markers. Compound action potentials were not suitable for CI position information but were sensitive to "cochlear health" (e.g., insertion trauma). SPs directly recorded from

  6. Evolution of impedance field telemetry after one day of activation in cochlear implant recipients.

    Directory of Open Access Journals (Sweden)

    Hao-Chun Hu

    Full Text Available Changes in impedance between 24 hours and one month after cochlear implantation have never been explored due to the inability to switch on within one day. This study examined the effect of early activation (within 24 hours on the evolution of electrode impedance with the aim of providing information on the tissue-to-electrode interface when electrical stimulation was commenced one day post implantation.We performed a retrospective review at a single institution. Patients who received a Nucleus 24RECA implant system (Cochlear, Sydney, Australia and underwent initial switch-on within 24 hours postoperatively were included. Impedance measurements were obtained intraoperatively and postoperatively at 1 day, 1 week, 4 weeks, and 8 weeks.A significant drop in impedance was noted 1 day after an initial activation within 24 hours followed by a significant rise in impedance in all channels until 1 week, after which the impedance behaved differently in different segments. Basal and mid-portion electrodes revealed a slight increase while apical electrodes showed a slight decrease in impedance from 1 week to 8 weeks postoperatively. Impedance was relatively stable 4 weeks after surgery.This is the first study to report the evolution of impedance in all channels between initial mapping 1 day and 1 month after cochlear implantation. The underlying mechanism for the differences in behavior between different segments of the electrode may be associated with the combined effect of dynamics among the interplay of cell cover formation, electrical stimulation, and fibrotic reaction.

  7. Music therapy as specific and complementary training for adults after cochlear implantation: A pilot study.

    Science.gov (United States)

    Hutter, E; Argstatter, H; Grapp, M; Plinkert, P K

    2015-09-01

    Although cochlear implant (CI) users achieve good speech comprehension, they experience difficulty perceiving music and prosody in speech. As the provision of music training in rehabilitation is limited, a novel concept of music therapy for rehabilitation of adult CI users was developed and evaluated in this pilot study. Twelve unilaterally implanted, postlingually deafened CI users attended ten sessions of individualized and standardized training. The training started about 6 weeks after the initial activation of the speech processor. Before and after therapy, psychological and musical tests were applied in order to evaluate the effects of music therapy. CI users completed the musical tests in two conditions: bilateral (CI + contralateral, unimplanted ear) and unilateral (CI only). After therapy, improvements were observed in the subjective sound quality (Hearing Implant Sound Quality Index) and the global score on the self-concept questionnaire (Multidimensional Self-Concept Scales) as well as in the musical subtests for melody recognition and for timbre identification in the unilateral condition. Discussion Preliminary results suggest improvements in subjective hearing and music perception, with an additional increase in global self-concept and enhanced daily listening capacities. The novel concept of individualized music therapy seems to provide an effective treatment option in the rehabilitation of adult CI users. Further investigations are necessary to evaluate effects in the area of prosody perception and to separate therapy effects from general learning effects in CI rehabilitation.

  8. Scalar position in cochlear implant surgery and outcome in residual hearing and the vestibular system.

    Science.gov (United States)

    Nordfalk, Karl Fredrik; Rasmussen, Kjell; Hopp, Einar; Greisiger, Ralf; Jablonski, Greg Eigner

    2014-02-01

    To evaluate the effect of the intracochlear electrode position on the residual hearing and VNG- and cVEMP responses. Prospective pilot study. Thirteen adult patients who underwent unilateral cochlear implant surgery were examined with high-resolution rotational tomography after cochlear implantation. All subjects were also tested with VNG, and 12 of the subjects were tested with cVEMP and audiometry before and after surgery. We found that although the electrode was originally planned to be positioned inside the scala tympani, only 8 of 13 had full insertion into the scala tympani. Loss of cVEMP response occurred to the same extent in the group with full scala tympani positioning and the group with scala vestibuli involvement. There was a non-significant difference in the loss of caloric response and residual hearing between the two groups. Interscalar dislocation of the electrode inside the cochlea was observed in two patients. A higher loss of residual hearing could be seen in the group with electrode dislocation between the scalae. Our findings indicate that intracochlear electrode dislocation is a possible cause to loss of residual hearing during cochlear implantation but cannot be the sole cause of postoperative vestibular loss.

  9. Investigating the effects of noise-estimation errors in simulated cochlear implant speech intelligibility

    DEFF Research Database (Denmark)

    Kressner, Abigail Anne; May, Tobias; Malik Thaarup Høegh, Rasmus

    2017-01-01

    A recent study suggested that the most important factor for obtaining high speech intelligibility in noise with cochlear implant recipients is to preserve the low-frequency amplitude modulations of speech across time and frequency by, for example, minimizing the amount of noise in speech gaps....... In contrast, other studies have argued that the transients provide the most information. Thus, the present study investigates the relative impact of these two factors in the framework of noise reduction by systematically correcting noise-estimation errors within speech segments, speech gaps......, and the transitions between them. Speech intelligibility in noise was measured using a cochlear implant simulation tested on normal-hearing listeners. The results suggest that minimizing noise in the speech gaps can substantially improve intelligibility, especially in modulated noise. However, significantly larger...

  10. Cochlear implants in children : development in interaction with the social context

    NARCIS (Netherlands)

    Wiefferink, K.C.

    2012-01-01

    Between 150 and 200 deaf children are born in the Netherlands each year. Deafness has major consequences for these children’s development, as it deprives them of access to spoken language. Since the 1990s, deaf children have been able to have a cochlear implant (CI), which enables them to experience

  11. The Sound Quality of Cochlear Implants: Studies With Single-sided Deaf Patients.

    Science.gov (United States)

    Dorman, Michael F; Natale, Sarah Cook; Butts, Austin M; Zeitler, Daniel M; Carlson, Matthew L

    2017-09-01

    The goal of the present study was to assess the sound quality of a cochlear implant for single-sided deaf (SSD) patients fit with a cochlear implant (CI). One of the fundamental, unanswered questions in CI research is "what does an implant sound like?" Conventional CI patients must use the memory of a clean signal, often decades old, to judge the sound quality of their CIs. In contrast, SSD-CI patients can rate the similarity of a clean signal presented to the CI ear and candidate, CI-like signals presented to the ear with normal hearing. For Experiment 1 four types of stimuli were created for presentation to the normal hearing ear: noise vocoded signals, sine vocoded signals, frequency shifted, sine vocoded signals and band-pass filtered, natural speech signals. Listeners rated the similarity of these signals to unmodified signals sent to the CI on a scale of 0 to 10 with 10 being a complete match to the CI signal. For Experiment 2 multitrack signal mixing was used to create natural speech signals that varied along multiple dimensions. In Experiment 1 for eight adult SSD-CI listeners, the best median similarity rating to the sound of the CI for noise vocoded signals was 1.9; for sine vocoded signals 2.9; for frequency upshifted signals, 1.9; and for band pass filtered signals, 5.5. In Experiment 2 for three young listeners, combinations of band pass filtering and spectral smearing lead to ratings of 10. The sound quality of noise and sine vocoders does not generally correspond to the sound quality of cochlear implants fit to SSD patients. Our preliminary conclusion is that natural speech signals that have been muffled to one degree or another by band pass filtering and/or spectral smearing provide a close, but incomplete, match to CI sound quality for some patients.

  12. Ultra-Wideband Transceivers for Cochlear Implants

    Directory of Open Access Journals (Sweden)

    Reisenzahn Alexander

    2005-01-01

    Full Text Available Ultra-wideband (UWB radio offers low power consumption, low power spectral density, high immunity against interference, and other benefits, not only for consumer electronics, but also for medical devices. A cochlear implant (CI is an electronic hearing apparatus, requiring a wireless link through human tissue. In this paper we propose an UWB link for a data rate of Mbps and a propagation distance up to 500 mm. Transmitters with step recovery diode and transistor pulse generators are proposed. Two types of antennas and their filter characteristics in the UWB spectrum will be discussed. An ultra-low-power back tunnel diode receiver prototype is described and compared with conventional detector receivers.

  13. The quality of life in cochlear implant children after two years from surgery and its impact on the family

    Directory of Open Access Journals (Sweden)

    Seyed Basir Hashemi

    2010-06-01

    Full Text Available Introduction: Cochlear implant has been established as effective option in rehabilitation of individuals with profound hearing impairment. As much of the studies about cochlear implants concentrated on aspects of speech perception and production, so we decided to study the quality of life of pre-lingual deaf children after at least 2 years of implantation. Materials and Methods: Twenty four patients’ parents in Fars Center were selected that had been implanted for at least 2 years and they filled the quality of life questionnaire. Three months later this questionnaire was filled again and results of two stages were analyzed. Results: In part of assessments p-value shows significant change in parent’s satisfaction. They believe that they can be beneficial for their children and in another part of this study, parents believe that the children communicate better, but still they need special care to do school homework and they have some difficulties in articulation. Conclusion: cochlear implantation is associated with improvement in quality of life. The improvement is significant in aspects of social communications and happiness.   

  14. Experiences of adult patients hearing loss postlingually with Cochlear Implant

    Directory of Open Access Journals (Sweden)

    Teresa María Lizcano Tejado

    2013-09-01

    Full Text Available Hearing loss is a significant public health problem. The incidence is difficult to establish because of the lack of data in people under age three, but is estimated about 1 per thousand for severe and profound hearing loss.A cochlear implant (CI is a device that converts sounds into electrical energy that triggers a sensation of hearing. The IC is indicated in patients with severe bilateral sensorineural hearing loss with null or poor benefit use of hearing aids.The general objective of this project is to understand the experiences of adult patients with severe-profound sensorineural hearing loss with IC postlingually throughout the implementation process.A personal vision of those implemented will allow us to learn how to face the possibility to hear and interact with their environment, applying this information to improve health care provided to them and identifying those areas where such assistance should be improved. Also allow us to compare the initial expectations and have been achieved, creating realistic expectations for future candidates.For its development we have designed a qualitative study, based on the principles and procedures of grounded theory, semistructured interviews, participant observation and discussion groups.The data will be analyzed using the software Nudist ViVo 9.

  15. Speech feature discrimination in deaf children following cochlear implantation

    Science.gov (United States)

    Bergeson, Tonya R.; Pisoni, David B.; Kirk, Karen Iler

    2002-05-01

    Speech feature discrimination is a fundamental perceptual skill that is often assumed to underlie word recognition and sentence comprehension performance. To investigate the development of speech feature discrimination in deaf children with cochlear implants, we conducted a retrospective analysis of results from the Minimal Pairs Test (Robbins et al., 1988) selected from patients enrolled in a longitudinal study of speech perception and language development. The MP test uses a 2AFC procedure in which children hear a word and select one of two pictures (bat-pat). All 43 children were prelingually deafened, received a cochlear implant before 6 years of age or between ages 6 and 9, and used either oral or total communication. Children were tested once every 6 months to 1 year for 7 years; not all children were tested at each interval. By 2 years postimplant, the majority of these children achieved near-ceiling levels of discrimination performance for vowel height, vowel place, and consonant manner. Most of the children also achieved plateaus but did not reach ceiling performance for consonant place and voicing. The relationship between speech feature discrimination, spoken word recognition, and sentence comprehension will be discussed. [Work supported by NIH/NIDCD Research Grant No. R01DC00064 and NIH/NIDCD Training Grant No. T32DC00012.

  16. Theory of Mind and Language in Children with Cochlear Implants

    Science.gov (United States)

    Remmel, Ethan; Peters, Kimberly

    2009-01-01

    Thirty children with cochlear implants (CI children), age range 3-12 years, and 30 children with normal hearing (NH children), age range 4-6 years, were tested on theory of mind and language measures. The CI children showed little to no delay on either theory of mind, relative to the NH children, or spoken language, relative to hearing norms. The…

  17. The role of spectral and temporal cues in voice gender discrimination by normal-hearing listeners and cochlear implant users.

    Science.gov (United States)

    Fu, Qian-Jie; Chinchilla, Sherol; Galvin, John J

    2004-09-01

    The present study investigated the relative importance of temporal and spectral cues in voice gender discrimination and vowel recognition by normal-hearing subjects listening to an acoustic simulation of cochlear implant speech processing and by cochlear implant users. In the simulation, the number of speech processing channels ranged from 4 to 32, thereby varying the spectral resolution; the cutoff frequencies of the channels' envelope filters ranged from 20 to 320 Hz, thereby manipulating the available temporal cues. For normal-hearing subjects, results showed that both voice gender discrimination and vowel recognition scores improved as the number of spectral channels was increased. When only 4 spectral channels were available, voice gender discrimination significantly improved as the envelope filter cutoff frequency was increased from 20 to 320 Hz. For all spectral conditions, increasing the amount of temporal information had no significant effect on vowel recognition. Both voice gender discrimination and vowel recognition scores were highly variable among implant users. The performance of cochlear implant listeners was similar to that of normal-hearing subjects listening to comparable speech processing (4-8 spectral channels). The results suggest that both spectral and temporal cues contribute to voice gender discrimination and that temporal cues are especially important for cochlear implant users to identify the voice gender when there is reduced spectral resolution.

  18. Resultados auditivos com o implante coclear multicanal em pacientes submetidos a cirurgia no Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo Auditory results with multicanal cochlear implant in patients submitted to cochlear implant surgery at University of São Paulo Medical School - Hospital das Clínicas

    Directory of Open Access Journals (Sweden)

    Ricardo Ferreira Bento

    2004-10-01

    an important alert for dangerous situations in the daily life. They are also unable to hear their own voices and for this people with profound deaf do not modulate their voices. The hearing aids are the first choice to treat deafness, but there are patients with severe damage of the auditory systems who cannot receive a useful hearing from normal hearing aids. The cochlear implant is the alternative for patients that cannot have good discriminatory ability wearing a powerful hearing aid and wish or need a better hearing. AIM: To study the hearing results of the adult patients who are using a multichannel cochlear implant system at the Department of Otolaryngology - University of Sao Paulo. STUDY DESIGN: Series study. MATERIAL AND METHOD: We selected 61 patients with a severe bilateral hearing loss that have been using the cochlear implant for at least six months. The hearing evaluation performed after using the device for six months included word and sentence recognition tests. RESULTS: The PTA of four patients reached 38.7 dB. Speech perception tests showed 713% recognition of open set sentences, 86.5% of vowels and 52.60% of monosyllabic. Most of our patients are able to speak on the telephone. CONCLUSION: Most of patients showed excellent results in open-set sentence and word tests.

  19. Radiation protection for the eyes of the children experiencing an operation of artificial cochlear implant against CT scan

    International Nuclear Information System (INIS)

    Liu Changsheng; Zheng Xiaohua; Li Maojing; Wei Wenzhou; Pan Ewu; Tang Guangqiao; Zhang Duanlian

    2006-01-01

    Objective: To optimize the CT scanning parameters in pediatric temporal bone examination with artificial cochlear implant and reduce its radiation hazards. Methods: The temporal bones of 87 patients with suspected inner ear disease which include 31 experienced artificial cochlear implant were scanned by HRCT. Regarding adult scan parameters as a criteria, properly adjusted the scanning dose and scanning angle until the quality of CT images was beyond the diagnosis demands. Finally the exposed doses, single scanning CT dose index weighted (CTDI w ) and dose length product (DLP) were analysed. Results: Compared with adult temporal bone scanning, the exposure value and CTDI w were reduced to 66.67%-83.33%, DLP of temporal bone scanning in pediatrics was reduced to 66.67%-83.33%, moreover, the imaging quality of tridimensional reconstruction for inner ear and implant electrode was improved. Conclusion: The proper reduction of CT scan exposure on preoperative and postoperative children with cochlear implants and the proper adjustment of scan angle can significantly reduce the exposure dose to local temporal bone and effectually avoid the damage to lens of children. (authors)

  20. Dichotic Listening Can Improve Perceived Clarity of Music in Cochlear Implant Users

    DEFF Research Database (Denmark)

    Vannson, Nicolas; Innes-Brown, Hamish; Marozeau, Jeremy

    2015-01-01

    Musical enjoyment for cochlear implant (CI) recipients is often reported to be unsatisfactory. Our goal was to determine whether the musical experience of postlingually deafened adult CI recipients could be enriched by presenting the bass and treble clef parts of short polyphonic piano pieces...

  1. Sensitivity to pulse phase duration in cochlear implant listeners: Effects of stimulation mode

    Science.gov (United States)

    Chatterjee, Monita; Kulkarni, Aditya M.

    2014-01-01

    The objective of this study was to investigate charge-integration at threshold by cochlear implant listeners using pulse train stimuli in different stimulation modes (monopolar, bipolar, tripolar). The results partially confirmed and extended the findings of previous studies conducted in animal models showing that charge-integration depends on the stimulation mode. The primary overall finding was that threshold vs pulse phase duration functions had steeper slopes in monopolar mode and shallower slopes in more spatially restricted modes. While the result was clear-cut in eight users of the Cochlear CorporationTM device, the findings with the six user of the Advanced BionicsTM device who participated were less consistent. It is likely that different stimulation modes excite different neuronal populations and/or sites of excitation on the same neuron (e.g., peripheral process vs central axon). These differences may influence not only charge integration but possibly also temporal dynamics at suprathreshold levels and with more speech-relevant stimuli. Given the present interest in focused stimulation modes, these results have implications for cochlear implant speech processor design and protocols used to map acoustic amplitude to electric stimulation parameters. PMID:25096116

  2. Demographic factors influencing educational placement of the hearing-impaired child with a cochlear implant.

    Science.gov (United States)

    Yehudai, Noam; Tzach, Naama; Shpak, Talma; Most, Tova; Luntz, Michal

    2011-08-01

    To analyze educational placement settings of Israeli children with cochlear implants (CIs) and evaluate the prognostic influence of the following demographic variables on mainstreaming: age at implantation, experience with CI, socioeconomic status, ethnicity, and parents' educational level. Retrospective review. Tertiary referral center. The study population comprised 245 children with severe-to-profound hearing impairment and at least 1 year of experience with a unilateral CI. Mean age at implantation was 4.5 ± 3.9 years, and mean duration of CI use was 5.4 ± 2.8 years. Follow-up review and statistical analysis of available data on educational placement after cochlear implantation. Placement in mainstream education. Regular schools were attended by 89 children (36.3%) and special education schools by 156 (63.7%). Variables found to be significantly associated with mainstream educational placement were younger age at implantation, higher level of parental education, higher socioeconomic status, and ethnicity. Multivariate analysis using a logistic regression model revealed that the factor with the highest positive correlation with mainstreaming was parental education level. Our results show that parental education, a variable that the health system cannot control, significantly influences postimplantation results in term of educational placement and can thus limit the chances of implanted children to achieve mainstream placement even when identified and implanted at an early age.

  3. Music enjoyment with cochlear implantation.

    Science.gov (United States)

    Prevoteau, Charlotte; Chen, Stephanie Y; Lalwani, Anil K

    2018-10-01

    Since the advent of cochlear implant (CI) surgery in the 1960s, there have been remarkable technological and surgical advances enabling excellent speech perception in quiet with many CI users able to use the telephone. However, many CI users struggle with music perception, particularly with the pitch-based and melodic elements of music. Yet remarkably, despite poor music perception, many CI users enjoy listening to music based on self-report questionnaires, and prospective studies have suggested a disassociation between music perception and enjoyment. Music enjoyment is arguably a more functional measure of one's listening experience, and thus enhancing one's listening experience is a worthy goal. Recent studies have shown that re-engineering music to reduce its complexity may enhance enjoyment in CI users and also delineate differences in musical preferences from normal hearing listeners. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. The cochlear nerve canal and internal auditory canal in children with normal cochlea but cochlear nerve deficiency

    Energy Technology Data Exchange (ETDEWEB)

    Yan, Fei; Li, Jianhong; Xian, Junfang; Wang, Zhenchang [Dept. of Radiology, Beijing Tongren Hospital, Capital Medical Univ., Beijing (China)], e-mail: cjr.wzhch@vip.163.com; Mo, Lingyan [Dept. of Otorhinolaryngology, Beijing Tongren Hospital, Capital Medical Univ., Beijing (China)

    2013-04-15

    Background: There is an increasing frequency of requests for cochlear implantation (CI) in deaf children and more detailed image information is necessary for selecting appropriate candidates. Cochlear nerve deficiency (CND) is a contraindication to CI. Magnetic resonance imaging (MRI) has been used to evaluate the integrity of the cochlear nerve. The abnormalities of the cochlear nerve canal (CNC) and internal auditory canal (IAC) have been reported to be associated with CND. Purpose: To correlate CNC manifestation, size, and IAC diameter on high-resolution CT (HRCT) with CND diagnosed by MRI in children. Material and Methods: HRCT images from 35 sensorineurally deaf children who had normal cochlea but bilateral or unilateral CND diagnosed by MRI were studied retrospectively. The CNC and IAC manifestation and size were assessed and correlated with CND. Results: CND was diagnosed by MRI in 54/70 ears (77.1%). Thirty-two ears had an absent cochlear nerve (59.3%), while 22 ears had a small cochlear nerve (40.7%). The CNC diameter was <1.5 mm in 36 ears (66.7%). The CNC diameter ranged between 1.5 and 2.0 mm in seven ears (13.0%) and was >2.0 mm in 11 ears (20.4%). The IAC diameter was <3.0 mm in 25 ears (46.3%) and >3.0 mm in 29 ears (53.7%). Conclusion: The hypoplastic CNC might be more highly indicative of CND than that of a narrow IAC.

  5. Living with cochlear implants: experiences of 17 adult patients in Sweden.

    Science.gov (United States)

    Hallberg, Lillemor R M; Ringdahl, Anders

    2004-02-01

    The aim of this grounded theory study was to gain a deeper understanding of what it means to profoundly deaf adults to undergo cochlear implantation and their experience of living with it daily. The aim of grounded theory is theorizing, i.e. constructing from data an explanatory scheme that systematically integrates various concepts and their relationships. The study group consisted of 10 women and seven men (age 29-78 years; mean age 56.5 years), who had had their cochlear implant (CI) for between 1 and 12 years (mean 4.1 years). Open taped interviews were carried out and analysed. The core category, coming back to life, defines a psychological process basic to existence, elucidating the existential value of hearing, including perceived harmony in life and becoming a part of the living world as important dimensions. This core concept is related to four additional emerging categories in a temporal order. Preventing disappointment concerns the decision to undergo the operation governed by the conception of having nothing to lose combined with low expectations of successful outcomes. Waiting in silence relates to experiences during the postoperative period such as sensations from the head and uncertainty about the outcome of surgery. The 'switch-on' was experienced as a significant revelation and the emotionally loaded starting point for their coming back to life. Retraining the brain concerns the lengthy audiovisual learning process. finally resulting in 'a car sounding like a car'. Strengthening of self-worth concerns psychosocial outcomes of cochlear implantation, in terms of less dependency and increased social participation. CIs provide a substantial improvement in the quality of life, as identified in the emerging generic process of coming back to life, fundamental for psychological existence.

  6. Comparative Impacts of Scala Vestibuli Versus Scala Tympani Cochlear Implantation on Auditory Performances and Programming Parameters in Partially Ossified Cochleae.

    Science.gov (United States)

    Trudel, Mathieu; Côté, Mathieu; Philippon, Daniel; Simonyan, David; Villemure-Poliquin, Noémie; Bussières, Richard

    2018-07-01

    To compare scala vestibuli versus scala tympani cochlear implantation in terms of postoperative auditory performances and programming parameters in patients with severe scala tympani ossification. Retrospective case-control study. Tertiary referral center. One hundred three pediatric and adult patients who underwent cochlear implant surgery between 2000 and 2016. Three groups were formed: a scala vestibuli group, a scala tympani with ossification group, and a scala tympani without ossification group. Patients were matched based on their age, sex, duration of deafness, and side of implantation (ratio of 1:2:2). Postoperative evaluation of auditory performances and programming parameters following intensive functional rehabilitation program completion. Multimedia adaptive test (MAT), hearing in noise test (HINT SNR +10 dB, HINT SNR +5 dB, and HINT SNR +0 dB), impedances, neural response telemetry thresholds (NRT), neural response imaging thresholds (NRI), comfortable levels (C-levels), and threshold levels (T-levels) were compared between groups. Twenty-one patients underwent scala vestibuli cochlear implantation: 19 adults and two children. Auditory performances were similar between groups, although sentence recognition in a noisy environment was slightly higher in the scala vestibuli group. Impedance values were also higher in the scala vestibuli group, but all other programming parameters were similar between groups. We present the largest series of patients with scala vestibuli cochlear implantation. This approach provides at least comparable auditory performances without having any deleterious effects on programming parameters. This viable and useful insertion route might be the primary surgical alternative when facing partial cochlear ossification.

  7. Benefits of Music Training in Mandarin-Speaking Pediatric Cochlear Implant Users

    Science.gov (United States)

    Fu, Qian-Jie; Galvin, John J., III; Wang, Xiaosong; Wu, Jiunn-Liang

    2015-01-01

    Purpose: The aims of this study were to assess young (5- to 10-year-old) Mandarin-speaking cochlear implant (CI) users' musical pitch perception and to assess the benefits of computer-based home training on performance. Method: Melodic contour identification (MCI) was used to assess musical pitch perception in 14 Mandarin-speaking pediatric CI…

  8. Optimization of programming parameters in children with the advanced bionics cochlear implant.

    Science.gov (United States)

    Baudhuin, Jacquelyn; Cadieux, Jamie; Firszt, Jill B; Reeder, Ruth M; Maxson, Jerrica L

    2012-05-01

    Cochlear implants provide access to soft intensity sounds and therefore improved audibility for children with severe-to-profound hearing loss. Speech processor programming parameters, such as threshold (or T-level), input dynamic range (IDR), and microphone sensitivity, contribute to the recipient's program and influence audibility. When soundfield thresholds obtained through the speech processor are elevated, programming parameters can be modified to improve soft sound detection. Adult recipients show improved detection for low-level sounds when T-levels are set at raised levels and show better speech understanding in quiet when wider IDRs are used. Little is known about the effects of parameter settings on detection and speech recognition in children using today's cochlear implant technology. The overall study aim was to assess optimal T-level, IDR, and sensitivity settings in pediatric recipients of the Advanced Bionics cochlear implant. Two experiments were conducted. Experiment 1 examined the effects of two T-level settings on soundfield thresholds and detection of the Ling 6 sounds. One program set T-levels at 10% of most comfortable levels (M-levels) and another at 10 current units (CUs) below the level judged as "soft." Experiment 2 examined the effects of IDR and sensitivity settings on speech recognition in quiet and noise. Participants were 11 children 7-17 yr of age (mean 11.3) implanted with the Advanced Bionics High Resolution 90K or CII cochlear implant system who had speech recognition scores of 20% or greater on a monosyllabic word test. Two T-level programs were compared for detection of the Ling sounds and frequency modulated (FM) tones. Differing IDR/sensitivity programs (50/0, 50/10, 70/0, 70/10) were compared using Ling and FM tone detection thresholds, CNC (consonant-vowel nucleus-consonant) words at 50 dB SPL, and Hearing in Noise Test for Children (HINT-C) sentences at 65 dB SPL in the presence of four-talker babble (+8 signal

  9. Waardenburg Syndrome: An Unusual Indication of Cochlear Implantation Experienced in 11 Patients.

    Science.gov (United States)

    Bayrak, Feda; Çatlı, Tolgahan; Atsal, Görkem; Tokat, Taşkın; Olgun, Levent

    2017-08-01

    The aim of this study was to present the surgical findings of children with Waardenburg syndrome (WS) and investigate speech development after cochlear implantation in this unique group of patients. A retrospective chart review of the patients diagnosed with WS and implanted between 1998 and 2015 was performed. Categories of auditory performance (CAP) test were used to assess the auditory skills of these patients. CAP is a nonlinear hierarchical scale used to rate a child's developing auditory abilities. Preoperative test results and intraoperative surgical findings of these patients have been presented. In total, 1835 cases were implanted a tour institution, and 1210 of these were children. Among these implantees, 11 were diagnosed with WS (0.59% of all implantees). Four of the 11 patients showed incomplete partition type 2bony labyrinth abnormality (Mondini deformity) and all patients showed intraoperative gusher during cochleostomy, which was subsided through routine interventions. No other complications occurred during surgery, and all patients showed satisfactory CAP results in the late postoperative period. Our experiences with cochlear implantation in patients with WS showed that the procedure is safe and effective in this group of patients. Surgeons should be aware of possible labyrinth malformations and intraoperative problems such as gusher in these patients. In long term, auditory performances may exhibit satisfactory results with optimal postoperative educational and supportive measures.

  10. Involving young people in decision making about sequential cochlear implantation.

    Science.gov (United States)

    Ion, Rebecca; Cropper, Jenny; Walters, Hazel

    2013-11-01

    The National Institute for Health and Clinical Excellence guidelines recommended young people who currently have one cochlear implant be offered assessment for a second, sequential implant, due to the reported improvements in sound localization and speech perception in noise. The possibility and benefits of group information and counselling assessments were considered. Previous research has shown advantages of group sessions involving young people and their families and such groups which also allow young people opportunity to discuss their concerns separately to their parents/guardians are found to be 'hugely important'. Such research highlights the importance of involving children in decision-making processes. Families considering a sequential cochlear implant were invited to a group information/counselling session, which included time for parents and children to meet separately. Fourteen groups were held with approximately four to five families in each session, totalling 62 patients. The sessions were facilitated by the multi-disciplinary team, with a particular psychological focus in the young people's session. Feedback from families has demonstrated positive support for this format. Questionnaire feedback, to which nine families responded, indicated that seven preferred the group session to an individual session and all approved of separate groups for the child and parents/guardians. Overall the group format and psychological focus were well received in this typically surgical setting and emphasized the importance of involving the young person in the decision-making process. This positive feedback also opens up the opportunity to use a group format in other assessment processes.

  11. Using Zebra-speech to study sequential and simultaneous speech segregation in a cochlear-implant simulation.

    Science.gov (United States)

    Gaudrain, Etienne; Carlyon, Robert P

    2013-01-01

    Previous studies have suggested that cochlear implant users may have particular difficulties exploiting opportunities to glimpse clear segments of a target speech signal in the presence of a fluctuating masker. Although it has been proposed that this difficulty is associated with a deficit in linking the glimpsed segments across time, the details of this mechanism are yet to be explained. The present study introduces a method called Zebra-speech developed to investigate the relative contribution of simultaneous and sequential segregation mechanisms in concurrent speech perception, using a noise-band vocoder to simulate cochlear implants. One experiment showed that the saliency of the difference between the target and the masker is a key factor for Zebra-speech perception, as it is for sequential segregation. Furthermore, forward masking played little or no role, confirming that intelligibility was not limited by energetic masking but by across-time linkage abilities. In another experiment, a binaural cue was used to distinguish the target and the masker. It showed that the relative contribution of simultaneous and sequential segregation depended on the spectral resolution, with listeners relying more on sequential segregation when the spectral resolution was reduced. The potential of Zebra-speech as a segregation enhancement strategy for cochlear implants is discussed.

  12. Comparisons between detection threshold and loudness perception for individual cochlear implant channels

    Science.gov (United States)

    Bierer, Julie Arenberg; Nye, Amberly D

    2014-01-01

    Objective The objective of the present study, performed in cochlear implant listeners, was to examine how the level of current required to detect single-channel electrical pulse trains relates to loudness perception on the same channel. The working hypothesis was that channels with relatively high thresholds, when measured with a focused current pattern, interface poorly to the auditory nerve. For such channels a smaller dynamic range between perceptual threshold and the most comfortable loudness would result, in part, from a greater sensitivity to changes in electrical field spread compared to low-threshold channels. The narrower range of comfortable listening levels may have important implications for speech perception. Design Data were collected from eight, adult cochlear implant listeners implanted with the HiRes90k cochlear implant (Advanced Bionics Corp.). The partial tripolar (pTP) electrode configuration, consisting of one intracochlear active electrode, two flanking electrodes carrying a fraction (σ) of the return current, and an extracochlear ground, was used for stimulation. Single-channel detection thresholds and most comfortable listening levels were acquired using the most focused pTP configuration possible (σ ≥ 0.8) to identify three channels for further testing – those with the highest, median, and lowest thresholds – for each subject. Threshold, equal-loudness contours (at 50% of the monopolar dynamic range), and loudness growth functions were measured for each of these three test channels using various partial tripolar fractions. Results For all test channels, thresholds increased as the electrode configuration became more focused. The rate of increase with the focusing parameter σ was greatest for the high-threshold channel compared to the median- and low-threshold channels. The 50% equal-loudness contours exhibited similar rates of increase in level across test channels and subjects. Additionally, test channels with the highest

  13. Speech Intelligibility and Personality Peer-Ratings of Young Adults with Cochlear Implants

    Science.gov (United States)

    Freeman, Valerie

    2018-01-01

    Speech intelligibility, or how well a speaker's words are understood by others, affects listeners' judgments of the speaker's competence and personality. Deaf cochlear implant (CI) users vary widely in speech intelligibility, and their speech may have a noticeable "deaf" quality, both of which could evoke negative stereotypes or…

  14. Language and Psychosocial Functioning among Deaf Learners with and without Cochlear Implants

    Science.gov (United States)

    Marschark, Marc; Machmer, Elizabeth; Spencer, Linda J.; Borgna, Georgianna; Durkin, Andreana; Convertino, Carol

    2018-01-01

    Various studies have examined psychosocial functioning and language abilities among deaf children with and without cochlear implants (CIs). Few, however, have explored how relations among those abilities might change with age and setting. Most relevant studies also have failed to consider that psychosocial functioning among both CI users and…

  15. Binaural release from masking with single- and multi-electrode stimulation in children with cochlear implantsa)

    Science.gov (United States)

    Todd, Ann E.; Goupell, Matthew J.; Litovsky, Ruth Y.

    2016-01-01

    Cochlear implants (CIs) provide children with access to speech information from a young age. Despite bilateral cochlear implantation becoming common, use of spatial cues in free field is smaller than in normal-hearing children. Clinically fit CIs are not synchronized across the ears; thus binaural experiments must utilize research processors that can control binaural cues with precision. Research to date has used single pairs of electrodes, which is insufficient for representing speech. Little is known about how children with bilateral CIs process binaural information with multi-electrode stimulation. Toward the goal of improving binaural unmasking of speech, this study evaluated binaural unmasking with multi- and single-electrode stimulation. Results showed that performance with multi-electrode stimulation was similar to the best performance with single-electrode stimulation. This was similar to the pattern of performance shown by normal-hearing adults when presented an acoustic CI simulation. Diotic and dichotic signal detection thresholds of the children with CIs were similar to those of normal-hearing children listening to a CI simulation. The magnitude of binaural unmasking was not related to whether the children with CIs had good interaural time difference sensitivity. Results support the potential for benefits from binaural hearing and speech unmasking in children with bilateral CIs. PMID:27475132

  16. Interdependence of linguistic and indexical speech perception skills in school-age children with early cochlear implantation.

    Science.gov (United States)

    Geers, Ann E; Davidson, Lisa S; Uchanski, Rosalie M; Nicholas, Johanna G

    2013-09-01

    This study documented the ability of experienced pediatric cochlear implant (CI) users to perceive linguistic properties (what is said) and indexical attributes (emotional intent and talker identity) of speech, and examined the extent to which linguistic (LSP) and indexical (ISP) perception skills are related. Preimplant-aided hearing, age at implantation, speech processor technology, CI-aided thresholds, sequential bilateral cochlear implantation, and academic integration with hearing age-mates were examined for their possible relationships to both LSP and ISP skills. Sixty 9- to 12-year olds, first implanted at an early age (12 to 38 months), participated in a comprehensive test battery that included the following LSP skills: (1) recognition of monosyllabic words at loud and soft levels, (2) repetition of phonemes and suprasegmental features from nonwords, and (3) recognition of key words from sentences presented within a noise background, and the following ISP skills: (1) discrimination of across-gender and within-gender (female) talkers and (2) identification and discrimination of emotional content from spoken sentences. A group of 30 age-matched children without hearing loss completed the nonword repetition, and talker- and emotion-perception tasks for comparison. Word-recognition scores decreased with signal level from a mean of 77% correct at 70 dB SPL to 52% at 50 dB SPL. On average, CI users recognized 50% of key words presented in sentences that were 9.8 dB above background noise. Phonetic properties were repeated from nonword stimuli at about the same level of accuracy as suprasegmental attributes (70 and 75%, respectively). The majority of CI users identified emotional content and differentiated talkers significantly above chance levels. Scores on LSP and ISP measures were combined into separate principal component scores and these components were highly correlated (r = 0.76). Both LSP and ISP component scores were higher for children who received a CI

  17. High resolution micro-CT scanning as an innovative tool for evaluation of the surgical positioning of cochlear implant electrodes.

    Science.gov (United States)

    Postnov, A; Zarowski, A; De Clerck, N; Vanpoucke, F; Offeciers, F E; Van Dyck, D; Peeters, S

    2006-05-01

    X-ray microtomography (micro-CT) is a new technique allowing for visualization of the internal structure of opaque specimens with a quasi-histological quality. Among multiple potential applications, the use of this technique in otology is very promising. Micro-CT appears to be ideally suited for in vitro visualization of the inner ear tissues as well as for evaluation of the electrode damage and/or surgical insertion trauma during implantation of the cochlear implant electrodes. This technique can greatly aid in design and development of new cochlear implant electrodes and is applicable for temporal bone studies. The main advantage of micro-CT is the practically artefact-free preparation of the samples and the possibility of evaluation of the interesting parameters along the whole insertion depth of the electrode. This paper presents the results of the first application of micro-CT for visualization of the inner ear structures in human temporal bones and for evaluation of the surgical positioning of the cochlear implant electrodes relative to the intracochlear soft tissues.

  18. Anestesia local e sedação para cirurgia de implante coclear: uma alternativa possível Local anesthesia for cochlear implant surgery: a possible alternative

    Directory of Open Access Journals (Sweden)

    Rogério Hamerschmidt

    2010-10-01

    Full Text Available Aanestesia geral sempre foi motivo de dúvida dos pacientes que vão ser submetidos a qualquer cirurgia, especialmente o implante coclear. Como já realizamos as cirurgias otológicas com anestesia local e sedação, julgamos perfeitamente possível a realização da cirurgia do implante coclear também com esse tipo de anestesia, diminuindo os riscos, a morbidade e os custos para o hospital. OBJETIVOS: Estudo prospectivo para demonstrar a técnica anestésica e cirúrgica utilizada em três casos de adultos submetidos ao implante coclear, avaliando a segurança e a eficácia de tal técnica. MATERIAL E MÉTODOS: Foram feitas três cirurgias de implante coclear, duas com implante Cochlear e uma com Med-EL, sem intercorrências transoperatórias, durante a telemetria e no pós-operatório imediato. RESULTADOS: Os três pacientes adultos tiveram alta hospitalar aproximadamente três horas após a cirurgia, deambulando, sem eventos nauseosos, relatando um pós-operatório mais fácil do que esperavam, mesmo no momento da telemetria intraoperatória. CONCLUSÃO: Anestesia local e sedação é uma alternativa para casos selecionados de pacientes para o implante coclear, principalmente naqueles de mais idade ou que apresentem contraindicação para a anestesia geral, os riscos e a morbidade são menores.The aim of this paper is to illustrate the possibility of performing a cochlear implant surgery with local anesthesia and sedation, the anesthetic technique and the advantages of that in comparison to a general anesthesia. AIMS: prospective study demonstrating the possibility of doing cochlear implant surgery under local anesthesia and sedation. MATERIALS AND METHODS: we describe three successful cases operated under local anesthesia, including neural telemetry and the conditions the patient presented after the surgery, with a very good recovery and no complications during and after the procedure. RESULTS: these three surgeries show the possibility of

  19. Cochlear implants and spoken language processing abilities: Review and assessment of the literature

    OpenAIRE

    Peterson, Nathaniel R.; Pisoni, David B.; Miyamoto, Richard T.

    2010-01-01

    Cochlear implants (CIs) process sounds electronically and then transmit electric stimulation to the cochlea of individuals with sensorineural deafness, restoring some sensation of auditory perception. Many congenitally deaf CI recipients achieve a high degree of accuracy in speech perception and develop near-normal language skills. Post-lingually deafened implant recipients often regain the ability to understand and use spoken language with or without the aid of visual input (i.e. lip reading...

  20. Effects of training on recognition of musical instruments presented through cochlear implant simulations.

    Science.gov (United States)

    Driscoll, Virginia D; Oleson, Jacob; Jiang, Dingfeng; Gfeller, Kate

    2009-01-01

    The simulation of the CI (cochlear implant) signal presents a degraded representation of each musical instrument, which makes recognition difficult. To examine the efficiency and effectiveness of three types of training on recognition of musical instruments as presented through simulations of the sounds transmitted through a CI. Participants were randomly assigned to one of three training conditions: repeated exposure, feedback, and direct instruction. Sixty-six adults with normal hearing. Each participant completed three training sessions per week, over a five-week time period, in which they listened to the CI simulations of eight different musical instruments. Analyses on percent of instruments identified correctly showed statistically significant differences between recognition accuracy of the three training conditions (p different types of training are differentially effective with regard to improving recognition of musical instruments presented through a degraded signal, which has practical implications for the auditory rehabilitation of persons who use cochlear implants.

  1. Sensory-motor relationships in speech production in post-lingually deaf cochlear-implanted adults and normal-hearing seniors: Evidence from phonetic convergence and speech imitation.

    Science.gov (United States)

    Scarbel, Lucie; Beautemps, Denis; Schwartz, Jean-Luc; Sato, Marc

    2017-07-01

    Speech communication can be viewed as an interactive process involving a functional coupling between sensory and motor systems. One striking example comes from phonetic convergence, when speakers automatically tend to mimic their interlocutor's speech during communicative interaction. The goal of this study was to investigate sensory-motor linkage in speech production in postlingually deaf cochlear implanted participants and normal hearing elderly adults through phonetic convergence and imitation. To this aim, two vowel production tasks, with or without instruction to imitate an acoustic vowel, were proposed to three groups of young adults with normal hearing, elderly adults with normal hearing and post-lingually deaf cochlear-implanted patients. Measure of the deviation of each participant's f 0 from their own mean f 0 was measured to evaluate the ability to converge to each acoustic target. showed that cochlear-implanted participants have the ability to converge to an acoustic target, both intentionally and unintentionally, albeit with a lower degree than young and elderly participants with normal hearing. By providing evidence for phonetic convergence and speech imitation, these results suggest that, as in young adults, perceptuo-motor relationships are efficient in elderly adults with normal hearing and that cochlear-implanted adults recovered significant perceptuo-motor abilities following cochlear implantation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Durability of Hearing Preservation after Cochlear Implantation with Conventional-Length Electrodes and Scala Tympani Insertion.

    Science.gov (United States)

    Sweeney, Alex D; Hunter, Jacob B; Carlson, Matthew L; Rivas, Alejandro; Bennett, Marc L; Gifford, Rene H; Noble, Jack H; Haynes, David S; Labadie, Robert F; Wanna, George B

    2016-05-01

    To analyze factors that influence hearing preservation over time in cochlear implant recipients with conventional-length electrode arrays located entirely within the scala tympani. Case series with planned chart review. Single tertiary academic referral center. A retrospective review was performed to analyze a subgroup of cochlear implant recipients with residual acoustic hearing. Patients were included in the study only if their electrode arrays remained fully in the scala tympani after insertion and serviceable acoustic hearing (≤80 dB at 250 Hz) was preserved. Electrode array location was verified through a validated radiographic assessment tool. Patients with scala tympani. In this group, the style of electrode array may influence residual hearing preservation over time. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2016.

  3. 3D-Flair sequence at 3T in cochlear otosclerosis

    International Nuclear Information System (INIS)

    Lombardo, Francesco; De Cori, Sara; Aghakhanyan, Gayane; Montanaro, Domenico; De Marchi, Daniele; Frijia, Francesca; Canapicchi, Raffaello; Fortunato, Susanna; Forli, Francesca; Berrettini, Stefano; Chiappino, Dante

    2016-01-01

    To assess the capability of three-dimensional fluid-attenuated inversion recovery (3D-FLAIR) sequences in detecting signal alterations of the endolabyrinthine fluid in patients with otosclerosis. 3D-FLAIR before and after (-/+) gadolinium (Gd) administration was added to the standard MR protocol and acquired in 13 patients with a clinical/audiological diagnosis of severe/profound hearing loss in otosclerosis who were candidates for cochlear implantation and in 11 control subjects using 3-T magnetic resonance imaging (MRI) equipment. The MRI signal of the fluid-filled cochlea was assessed both visually and calculating the signal intensity ratio (SIR = signal intensity cochlea/brainstem). We revealed no endocochlear signal abnormalities on T1-weighted -/+ Gd images for either group, while on 3D-FLAIR we found bilateral hyperintensity with enhancement after Gd administration in eight patients and bilateral hyperintensity without enhancement in one patient. No endocochlear signal abnormalities were detected in other patients or the control group. Using 3-T MRI equipment, the 3D-FLAIR -/+ Gd sequence is able to detect the blood-labyrinth barrier (BLB) breakdown responsible for alterations of the endolabyrinthine fluid in patients with cochlear otosclerosis. We believe that 3D-FLAIR +/- Gd is an excellent imaging modality to assess the intra-cochlear damage in otosclerosis patients. (orig.)

  4. 3D-Flair sequence at 3T in cochlear otosclerosis

    Energy Technology Data Exchange (ETDEWEB)

    Lombardo, Francesco; De Cori, Sara; Aghakhanyan, Gayane; Montanaro, Domenico; De Marchi, Daniele; Frijia, Francesca; Canapicchi, Raffaello [Fondazione CNR Regione Toscana ' ' G. Monasterio' ' , Neuroradiology Unit, Pisa (Italy); Fortunato, Susanna; Forli, Francesca; Berrettini, Stefano [University of Pisa, ENT Audiology Phoniatry Unit, Department of Neuroscience, Pisa (Italy); Chiappino, Dante [Fondazione CNR Regione Toscana ' ' G. Monasterio' ' , Department of Radiology, Massa (Italy)

    2016-10-15

    To assess the capability of three-dimensional fluid-attenuated inversion recovery (3D-FLAIR) sequences in detecting signal alterations of the endolabyrinthine fluid in patients with otosclerosis. 3D-FLAIR before and after (-/+) gadolinium (Gd) administration was added to the standard MR protocol and acquired in 13 patients with a clinical/audiological diagnosis of severe/profound hearing loss in otosclerosis who were candidates for cochlear implantation and in 11 control subjects using 3-T magnetic resonance imaging (MRI) equipment. The MRI signal of the fluid-filled cochlea was assessed both visually and calculating the signal intensity ratio (SIR = signal intensity cochlea/brainstem). We revealed no endocochlear signal abnormalities on T1-weighted -/+ Gd images for either group, while on 3D-FLAIR we found bilateral hyperintensity with enhancement after Gd administration in eight patients and bilateral hyperintensity without enhancement in one patient. No endocochlear signal abnormalities were detected in other patients or the control group. Using 3-T MRI equipment, the 3D-FLAIR -/+ Gd sequence is able to detect the blood-labyrinth barrier (BLB) breakdown responsible for alterations of the endolabyrinthine fluid in patients with cochlear otosclerosis. We believe that 3D-FLAIR +/- Gd is an excellent imaging modality to assess the intra-cochlear damage in otosclerosis patients. (orig.)

  5. Analog Integrated Circuit and System Design for a Compact, Low-Power Cochlear Implant

    NARCIS (Netherlands)

    Ngamkham, W.

    2015-01-01

    Cochlear Implants (CIs) are prosthetic devices that restore hearing in profoundly deaf patients by bypassing the damaged parts of the inner ear and directly stimulating the remaining auditory nerve fibers in the cochlea with electrical pulses. This thesis describs the electronic circuit design of

  6. Bilateral implant reconstruction does not affect the quality of postmastectomy radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Ho, Alice Y., E-mail: hoa1234@mskcc.org [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, NY (United States); Patel, Nisha [Drexel University College of Medicine, Philadelphia, PA (United States); Ohri, Nisha [Department of Radiation Oncology, Mount Sinai School of Medicine, New York, NY (United States); Morrow, Monica [Department of Surgery, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Mehrara, Babak J.; Disa, Joseph J.; Cordeiro, Peter G. [Department of Plastic Surgery, Memorial Sloan-Kettering Cancer Center, New York, NY (United States); Shi, Weiji; Zhang, Zhigang [Department of Biostatistics and Epidemiology, Memorial Sloan-Kettering Cancer Center, New York, NY (United States); Gelblum, Daphna [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, NY (United States); Nerbun, Claire T.; Woch, Katherine M.; Ballangrud, Ase [Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, NY (United States); McCormick, Beryl; Powell, Simon N. [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, NY (United States)

    2014-04-01

    To determine if the presence of bilateral implants, in addition to other anatomic and treatment-related variables, affects coverage of the target volume and dose to the heart and lung in patients receiving postmastectomy radiation therapy (PMRT). A total of 197 consecutive women with breast cancer underwent mastectomy and immediate tissue expander (TE) placement, with or without exchange for a permanent implant (PI) before radiation therapy at our center. PMRT was delivered with 2 tangential beams + supraclavicular lymph node field (50 Gy). Patients were grouped by implant number: 51% unilateral (100) and 49% bilateral (97). The planning target volume (PTV) (defined as implant + chest wall + nodes), heart, and ipsilateral lung were contoured and the following parameters were abstracted from dose-volume histogram (DVH) data: PTV D{sub 95%} > 98%, Lung V{sub 20}Gy > 30%, and Heart V{sub 25}Gy > 5%. Univariate (UVA) and multivariate analyses (MVA) were performed to determine the association of variables with these parameters. The 2 groups were well balanced for implant type and volume, internal mammary node (IMN) treatment, and laterality. In the entire cohort, 90% had PTV D{sub 95%} > 98%, indicating excellent coverage of the chest wall. Of the patients, 27% had high lung doses (V{sub 20}Gy > 30%) and 16% had high heart doses (V{sub 25}Gy > 5%). No significant factors were associated with suboptimal PTV coverage. On MVA, IMN treatment was found to be highly associated with high lung and heart doses (both p < 0.0001), but implant number was not (p = 0.54). In patients with bilateral implants, IMN treatment was the only predictor of dose to the contralateral implant (p = 0.001). In conclusion, bilateral implants do not compromise coverage of the target volume or increase lung and heart dose in patients receiving PMRT. The most important predictor of high lung and heart doses in patients with implant-based reconstruction, whether unilateral or bilateral, is treatment of

  7. Verbal Processing Speed and Executive Functioning in Long-Term Cochlear Implant Users

    Science.gov (United States)

    AuBuchon, Angela M.; Pisoni, David B.; Kronenberger, William G.

    2015-01-01

    Purpose: The purpose of this study was to report how "verbal rehearsal speed" (VRS), a form of covert speech used to maintain verbal information in working memory, and another verbal processing speed measure, perceptual encoding speed, are related to 3 domains of executive function (EF) at risk in cochlear implant (CI) users: verbal…

  8. Probing the Electrode–Neuron Interface With Focused Cochlear Implant Stimulation

    Science.gov (United States)

    Bierer, Julie Arenberg

    2010-01-01

    Cochlear implants are highly successful neural prostheses for persons with severe or profound hearing loss who gain little benefit from hearing aid amplification. Although implants are capable of providing important spectral and temporal cues for speech perception, performance on speech tests is variable across listeners. Psychophysical measures obtained from individual implant subjects can also be highly variable across implant channels. This review discusses evidence that such variability reflects deviations in the electrode–neuron interface, which refers to an implant channel's ability to effectively stimulate the auditory nerve. It is proposed that focused electrical stimulation is ideally suited to assess channel-to-channel irregularities in the electrode–neuron interface. In implant listeners, it is demonstrated that channels with relatively high thresholds, as measured with the tripolar configuration, exhibit broader psychophysical tuning curves and smaller dynamic ranges than channels with relatively low thresholds. Broader tuning implies that frequency-specific information intended for one population of neurons in the cochlea may activate more distant neurons, and a compressed dynamic range could make it more difficult to resolve intensity-based information, particularly in the presence of competing noise. Degradation of both types of cues would negatively affect speech perception. PMID:20724356

  9. Pterygoid implants for maxillofacial rehabilitation of a patient with a bilateral maxillectomy defect.

    Science.gov (United States)

    Bidra, Avinash S; May, George W; Tharp, Greggory E; Chambers, Mark S

    2013-02-01

    Bilateral maxillectomy is known to have serious esthetic and functional consequences. The retention and support of a maxillary obturator prosthesis in these patients is particularly challenging. Surgical placement of implants is also challenging because of the lack of available bone. Therefore, implant placement into remote sites such as zygoma has been advocated. Very few articles in the literature have discussed the use of pterygoid/pterygomaxillary implants in patients undergoing maxillectomy. This case report describes the maxillofacial rehabilitation of an elderly man who underwent a bilateral subtotal maxillectomy due to basaloid squamous cell carcinoma of the hard palate. After initial healing, the patient had a pterygoid implant placed on each side of the oral cavity. Zygomatic implants were also attempted, but they failed to osseointegrate. Both pterygoid implants showed successful osseointegration. These 2 implants significantly helped to retain a hollow maxillary obturator prosthesis that aided in improved swallowing, speech, and esthetics. To the authors' knowledge, this is the first report in the literature that describes usage of pterygoid implants for rehabilitation of a patient undergoing bilateral maxillectomy.

  10. Strengths and difficulties in children with cochlear implants--comparing self-reports with reports from parents and teachers.

    Science.gov (United States)

    Anmyr, Lena; Larsson, Kjerstin; Olsson, Mariann; Freijd, Anders

    2012-08-01

    The aim was to explore and compare how children with cochlear implants, their parents, and their teachers perceive the children's mental health in terms of emotional and behavioral strengths and difficulties. The self-report, parents', and teachers' versions of the Strengths and Difficulties Questionnaire (SDQ) were used to assess the mental health of 22 children with cochlear implants. The children's assessments were then compared to the parents' and 17 teachers' assessments. The data were analyzed using the SPSS software package. Total difficulties (p=.000), emotional symptoms (p=.000), and conduct problems (p=.007) were greater according to the children than according to parents and teachers. Younger children (9 years, n=12) reported more emotional symptoms than older children (12 and 15 years, n=10). Almost a quarter of the children rated themselves in a way indicating mental ill-health. Parents and teachers each indicated mental ill-health for one child. Children with cochlear implants express greater concerns about their mental health than their parents and teachers do. This is important knowledge for adults in families, schools, and health care in order to support these children and offer treatment when needed. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  11. Residual neural processng of musical sound features in adult cochlear implant users

    DEFF Research Database (Denmark)

    Timm, Lydia; Vuust, Peter; Brattico, Elvira

    2014-01-01

    setting lasting only 20 min. The presentation of stimuli did not require the participants' attention, allowing the study of the early automatic stage of feature processing in the auditory cortex. For the CI users, we obtained mismatch negativity (MMN) brain responses to five feature changes...... neural skills for music processing even in CI users who have been implanted in adolescence or adulthood. HIGHLIGHTS: -Automatic brain responses to musical feature changes reflect the limitations of central auditory processing in adult Cochlear Implant users.-The brains of adult CI users automatically...

  12. Dichotic Listening Can Improve Perceived Clarity of Music in Cochlear Implant Users.

    Science.gov (United States)

    Vannson, Nicolas; Innes-Brown, Hamish; Marozeau, Jeremy

    2015-08-26

    Musical enjoyment for cochlear implant (CI) recipients is often reported to be unsatisfactory. Our goal was to determine whether the musical experience of postlingually deafened adult CI recipients could be enriched by presenting the bass and treble clef parts of short polyphonic piano pieces separately to each ear (dichotic). Dichotic presentation should artificially enhance the lateralization cues of each part and help the listeners to better segregate them and thus provide greater clarity. We also hypothesized that perception of the intended emotion of the pieces and their overall enjoyment would be enhanced in the dichotic mode compared with the monophonic (both parts in the same ear) and the diotic mode (both parts in both ears). Twenty-eight piano pieces specifically composed to induce sad or happy emotions were selected. The tempo of the pieces, which ranged from lento to presto covaried with the intended emotion (from sad to happy). Thirty participants (11 normal-hearing listeners, 11 bimodal CI and hearing-aid users, and 8 bilaterally implanted CI users) participated in this study. Participants were asked to rate the perceived clarity, the intended emotion, and their preference of each piece in different listening modes. Results indicated that dichotic presentation produced small significant improvements in subjective ratings based on perceived clarity and preference. We also found that preference and clarity ratings were significantly higher for pieces with fast tempi compared with slow tempi. However, no significant differences between diotic and dichotic presentation were found for the participants' preference ratings, or their judgments of intended emotion. © The Author(s) 2015.

  13. Dichotic Listening Can Improve Perceived Clarity of Music in Cochlear Implant Users

    Directory of Open Access Journals (Sweden)

    Nicolas Vannson

    2015-08-01

    Full Text Available Musical enjoyment for cochlear implant (CI recipients is often reported to be unsatisfactory. Our goal was to determine whether the musical experience of postlingually deafened adult CI recipients could be enriched by presenting the bass and treble clef parts of short polyphonic piano pieces separately to each ear (dichotic. Dichotic presentation should artificially enhance the lateralization cues of each part and help the listeners to better segregate them and thus provide greater clarity. We also hypothesized that perception of the intended emotion of the pieces and their overall enjoyment would be enhanced in the dichotic mode compared with the monophonic (both parts in the same ear and the diotic mode (both parts in both ears. Twenty-eight piano pieces specifically composed to induce sad or happy emotions were selected. The tempo of the pieces, which ranged from lento to presto covaried with the intended emotion (from sad to happy. Thirty participants (11 normal-hearing listeners, 11 bimodal CI and hearing-aid users, and 8 bilaterally implanted CI users participated in this study. Participants were asked to rate the perceived clarity, the intended emotion, and their preference of each piece in different listening modes. Results indicated that dichotic presentation produced small significant improvements in subjective ratings based on perceived clarity. We also found that preference and clarity ratings were significantly higher for pieces with fast tempi compared with slow tempi. However, no significant differences between diotic and dichotic presentation were found for the participants’ preference ratings, or their judgments of intended emotion.

  14. Social Media Utilization in the Cochlear Implant Community

    Science.gov (United States)

    Saxena, Rajeev C.; Lehmann, Ashton E.; Hight, A. Ed; Darrow, Keith; Remenschneider, Aaron; Kozin, Elliott D.; Lee, Daniel J.

    2015-01-01

    Background More than 200,000 individuals worldwide have received a cochlear implant (CI). Social media Websites may provide a paramedical community for those who possess or are interested in a CI. The utilization patterns of social media by the CI community, however, have not been thoroughly investigated. Purpose The purpose of this study was to investigate participation of the CI community in social media Websites. Research Design We conducted a systematic survey of online CI-related social media sources. Using standard search engines, the search terms cochlear implant, auditory implant, forum, and blog identified relevant social media platforms and Websites. Social media participation was quantified by indices of membership and posts. Study Sample Social media sources included Facebook, Twitter, YouTube, blogs, and online forums. Each source was assigned one of six functional categories based on its description. Intervention No intervention was performed. Data Collection and Analysis We conducted all online searches in February 2014. Total counts of each CI-related social media source were summed, and descriptive statistics were calculated. Results More than 350 sources were identified, including 60 Facebook groups, 36 Facebook pages, 48 Twitter accounts, 121 YouTube videos, 13 forums, and 95 blogs. The most active online communities were Twitter accounts, which totaled 35,577 members, and Facebook groups, which totaled 17,971 members. CI users participated in Facebook groups primarily for general information/support (68%). Online forums were the next most active online communities by membership. The largest forum contained approximately 9,500 topics with roughly 127,000 posts. CI users primarily shared personal stories through blogs (92%), Twitter (71%), and YouTube (62%). Conclusions The CI community engages in the use of a wide range of online social media sources. The CI community uses social media for support, advocacy, rehabilitation information, research

  15. Hearing history influences voice gender perceptual performance in cochlear implant users.

    Science.gov (United States)

    Kovačić, Damir; Balaban, Evan

    2010-12-01

    The study was carried out to assess the role that five hearing history variables (chronological age, age at onset of deafness, age of first cochlear implant [CI] activation, duration of CI use, and duration of known deafness) play in the ability of CI users to identify speaker gender. Forty-one juvenile CI users participated in two voice gender identification tasks. In a fixed, single-interval task, subjects listened to a single speech item from one of 20 adult male or 20 adult female speakers and had to identify speaker gender. In an adaptive speech-based voice gender discrimination task with the fundamental frequency difference between the voices as the adaptive parameter, subjects listened to a pair of speech items presented in sequential order, one of which was always spoken by an adult female and the other by an adult male. Subjects had to identify the speech item spoken by the female voice. Correlation and regression analyses between perceptual scores in the two tasks and the hearing history variables were performed. Subjects fell into three performance groups: (1) those who could distinguish voice gender in both tasks, (2) those who could distinguish voice gender in the adaptive but not the fixed task, and (3) those who could not distinguish voice gender in either task. Gender identification performance for single voices in the fixed task was significantly and negatively related to the duration of deafness before cochlear implantation (shorter deafness yielded better performance), whereas performance in the adaptive task was weakly but significantly related to age at first activation of the CI device, with earlier activations yielding better scores. The existence of a group of subjects able to perform adaptive discrimination but unable to identify the gender of singly presented voices demonstrates the potential dissociability of the skills required for these two tasks, suggesting that duration of deafness and age of cochlear implantation could have

  16. Processing of Acoustic Cues in Lexical-Tone Identification by Pediatric Cochlear-Implant Recipients

    Science.gov (United States)

    Peng, Shu-Chen; Lu, Hui-Ping; Lu, Nelson; Lin, Yung-Song; Deroche, Mickael L. D.; Chatterjee, Monita

    2017-01-01

    Purpose: The objective was to investigate acoustic cue processing in lexical-tone recognition by pediatric cochlear-implant (CI) recipients who are native Mandarin speakers. Method: Lexical-tone recognition was assessed in pediatric CI recipients and listeners with normal hearing (NH) in 2 tasks. In Task 1, participants identified naturally…

  17. Speech Recognition in Adults With Cochlear Implants: The Effects of Working Memory, Phonological Sensitivity, and Aging.

    Science.gov (United States)

    Moberly, Aaron C; Harris, Michael S; Boyce, Lauren; Nittrouer, Susan

    2017-04-14

    Models of speech recognition suggest that "top-down" linguistic and cognitive functions, such as use of phonotactic constraints and working memory, facilitate recognition under conditions of degradation, such as in noise. The question addressed in this study was what happens to these functions when a listener who has experienced years of hearing loss obtains a cochlear implant. Thirty adults with cochlear implants and 30 age-matched controls with age-normal hearing underwent testing of verbal working memory using digit span and serial recall of words. Phonological capacities were assessed using a lexical decision task and nonword repetition. Recognition of words in sentences in speech-shaped noise was measured. Implant users had only slightly poorer working memory accuracy than did controls and only on serial recall of words; however, phonological sensitivity was highly impaired. Working memory did not facilitate speech recognition in noise for either group. Phonological sensitivity predicted sentence recognition for implant users but not for listeners with normal hearing. Clinical speech recognition outcomes for adult implant users relate to the ability of these users to process phonological information. Results suggest that phonological capacities may serve as potential clinical targets through rehabilitative training. Such novel interventions may be particularly helpful for older adult implant users.

  18. Auditory and verbal memory predictors of spoken language skills in children with cochlear implants

    NARCIS (Netherlands)

    Hoog, B.E. de; Langereis, M.C.; Weerdenburg, M. van; Keuning, J.; Knoors, H.; Verhoeven, L.

    2016-01-01

    BACKGROUND: Large variability in individual spoken language outcomes remains a persistent finding in the group of children with cochlear implants (CIs), particularly in their grammatical development. AIMS: In the present study, we examined the extent of delay in lexical and morphosyntactic spoken

  19. Auditory and verbal memory predictors of spoken language skills in children with cochlear implants

    NARCIS (Netherlands)

    Hoog, B.E. de; Langereis, M.C.; Weerdenburg, M.W.C. van; Keuning, J.; Knoors, H.E.T.; Verhoeven, L.T.W.

    2016-01-01

    Background: Large variability in individual spoken language outcomes remains a persistent finding in the group of children with cochlear implants (CIs), particularly in their grammatical development. Aims: In the present study, we examined the extent of delay in lexical and morphosyntactic spoken

  20. Simultaneous Communication and Cochlear Implants in the Classroom?

    Science.gov (United States)

    Blom, Helen C; Marschark, Marc

    2015-09-01

    This study was designed to evaluate the potential of simultaneous communication (sign and speech together) to support classroom learning by college students who use cochlear implants (CIs). Metacognitive awareness of learning also was evaluated. A within-subjects design involving 40 implant users indicated that the student participants learned significantly more when material was presented via simultaneous communication than spoken language overall, but a statistical interaction indicated that the difference held only with more difficult material. Learning in the speech-only condition was positively related to the students' spoken language skills, their confidence with spoken language, and their receptive simultaneous communication skills. Learning in that condition was negatively related to the age at which the participants learned to sign. Findings were interpreted to indicate that simultaneous communication can be beneficial for classroom learning by college students with CIs, at least with more complex material or when information redundancy is otherwise important. Further research is needed to determine who is likely to benefit in what settings.