WorldWideScience

Sample records for biceps tendon sheath

  1. Fibroma of the tendon sheath of the long head of the biceps tendon

    International Nuclear Information System (INIS)

    Maeseneer, Michel de; Shahabpour, Maryam; Isacker, Tom van; Lenchik, Leon; Caillie, Marie-Astrid van

    2014-01-01

    Fibroma of the tendon sheath is a benign tumor that is less common than giant cell tumor of the tendon sheath. Both tumors may present as a painless, slowly enlarging mass. Radiological findings may be similar for both tumors. Histologically, fibroma of the tendon sheath lacks the hemosiderin-laden macrophages that are typical for giant cell tumor of the tendon sheath. We report on a 49-year-old woman with fibroma of the tendon sheath of the long head of the biceps tendon. In our case, on MR images, we observed band-like hypointense areas centrally in the tumor, mild patchy contrast enhancement, and most importantly, no decrease of signal intensity on gradient echo images. These characteristics reflected histological findings. (orig.)

  2. Evaluation of the Effusion within Biceps Long Head Tendon Sheath Using Ultrasonography

    Science.gov (United States)

    Park, In; Lee, Hyo-Jin; Kim, Sung-Eun; Bae, Sung-Ho; Lee, Kwang-Yeol; Park, Kwang-Sun

    2015-01-01

    Background Many shoulder diseases are related to glenohumeral joint synovitis and effusion. The purpose of the present study is to detect effusion within the biceps long head tendon sheath as the sign of glenohumeral joint synovitis using ultrasonography, and to evaluate the clinical meaning of effusion within the biceps long head tendon sheath. Methods A consecutive series of 569 patients who underwent ultrasonography for shoulder pain were reviewed retrospectively and ultimately, 303 patients were included. The authors evaluated the incidence and amount of the effusion within the biceps long head tendon sheath on the ultrasonographic short axis view. Furthermore, the authors evaluated the correlation between the amount of effusion within the biceps long head tendon sheath and the range of motion and the functional score. Results The effusion within the biceps long head tendon sheath was detected in 58.42% of the patients studied: 69.23% in adhesive capsulitis, 56.69% in rotator cuff tear, 41.03% in calcific tendinitis, and 33.33% in biceps tendinitis. The average amount of the effusion within the biceps long head tendon sheath was 1.7 ± 1.6 mm, and it was measured to be the largest in adhesive capsulitis. The amount of effusion within biceps long head tendon sheath showed a moderate to high degree of correlation with the range of motion, and a low degree of correlation with the functional score and visual analogue scale for pain in each type of shoulder disease. Conclusions The effusion within the biceps long head tendon sheath is closely related to the range of motion and clinical scores in patients with painful shoulders. Ultrasonographic detection of the effusion within the biceps long head tendon sheath might be a simple and easy method to evaluate shoulder function. PMID:26330958

  3. Arthrography of the biceps tendon

    International Nuclear Information System (INIS)

    Ahovuo, J.; Linden, H.; Hovi, I.; Paavolainen, P.; Bjoerkenheim, J.M.

    1988-01-01

    The purpose of this study was to analyse the factors having an influence on the arthrographic imaging of the biceps tendon. The study comprised 174 patients suffering from chronic shoulder pain. They underwent conventional shoulder arthrography with sodium meglumine metrizoate or metrizamide as a contrast medium. In the patients with a full-thickness tear of the rotator cuff, the biceps tendon sheath failed to fill with contrast medium more often than in those with an intact tendinous cuff. Metrizamide filled the biceps tendon sheath more readily than sodium meglumine metrizoate in patients with a full-thickness tear of the ortator cuff. The volume of the contrast medium injected had no influence on the imaging of the biceps tendon. (orig.)

  4. Correlation of the SLAP lesion with lesions of the medial sheath of the biceps tendon and intra-articular subscapularis tendon

    Directory of Open Access Journals (Sweden)

    Bennett William

    2009-01-01

    Full Text Available Background: Superior labral anterior to posterior (SLAP lesions have been well described in the literature and are thought to be secondary to traction injuries to the biceps anchor and/or falls on the outstretched arm. The pulley has recently been described as a structure that aids in the prevention of biceps instability. The intra-articular subscapularis insertion (IASS has been noted to contribute to the robust nature of the medial sheath. The purpose of the study was to determine a potential correlation of SLAP lesions and pulley lesions with/without IASS lesions, (hereafter referred to as medial sheath as forces that can disrupt the biceps anchor and may also disrupt structures of the medial sheath or vice-versa. Materials and Methods: Three hundred and sixteen consecutive shoulder arthroscopies performed by one surgeon were reviewed retrospectively. Operative reports and arthroscopic pictures were carefully reviewed with particular attention paid to the labral and pulley pathology. Selection bias was noted as the author had never operated primarily for a Type 1 SLAP lesion. Following, however, and as such, the exclusion criteria, was a Type 1 SLAP. Results: There were a total of 30 SLAP lesions and a total of 126 medial sheath lesions. There were 13 patients who had both SLAP and medial sheath lesions. There were 17 patients who had a SLAP lesion without a medial sheath lesion. There were 96 medial sheath lesions without a SLAP. A comparison of rates between patients who had a medial sheath lesion with a SLAP and those who had a medial sheath lesion without a SLAP, for the 316 patients, and when tested with a Fisher exact test revealed that there was no statistical significance, P = 0.673. The prevalence of SLAP lesions in this population of 316 patients was 9.4%, Buford 1%, medial sheath lesions 39%, and SLAP and medial sheath lesions 4%. Interestingly, there were three Buford complexes, all associated with a SLAP and one Buford complex

  5. Tendinopathy of the long head of the biceps tendon: histopathologic analysis of the extra-articular biceps tendon and tenosynovium

    Directory of Open Access Journals (Sweden)

    Streit JJ

    2015-03-01

    Full Text Available Jonathan J Streit,1 Yousef Shishani,1 Mark Rodgers,2 Reuben Gobezie1 1The Cleveland Shoulder Institute, 2Department of Pathology, University Hospitals of Cleveland, Cleveland, OH, USA Background: Bicipital tendinitis is a common cause of anterior shoulder pain, but there is no evidence that acute inflammation of the extra-articular long head of the biceps (LHB tendon is the root cause of this condition. We evaluated the histologic findings of the extra-articular portion of the LHB tendon and synovial sheath in order to compare those findings to known histologic changes seen in other tendinopathies. Methods: Twenty-six consecutive patients (mean age 45.4±13.7 years underwent an open subpectoral biceps tenodesis for anterior shoulder pain localized to the bicipital groove. Excised tendons were sent for histologic analysis. Specimens were graded using a semiquantitative scoring system to evaluate tenocyte morphology, the presence of ground substance, collagen bundle characteristics, and vascular changes. Results: Chronic inflammation was noted in only two of 26 specimens, and no specimen demonstrated acute inflammation. Tenocyte enlargement and proliferation, characterized by increased roundness and size of the cell and nucleus with proteoglycan matrix expansion and myxoid degenerative changes, was found in all 26 specimens. Abundant ground substance, collagen bundle changes, and increased vascularization were visualized in all samples. Conclusion: Anterior shoulder pain attributed to the biceps tendon does not appear to be due to an inflammatory process in most cases. The histologic findings of the extra-articular portion of the LHB tendon and synovial sheath are similar to the pathologic findings in de Quervain tenosynovitis at the wrist, and may be due to a chronic degenerative process similar to this and other tendinopathies of the body. Keywords: biceps tendinitis, biceps tendinopathy, tenosynovium, anterior shoulder pain, long head biceps

  6. Tendinopathy of the long head of the biceps tendon: histopathologic analysis of the extra-articular biceps tendon and tenosynovium.

    Science.gov (United States)

    Streit, Jonathan J; Shishani, Yousef; Rodgers, Mark; Gobezie, Reuben

    2015-01-01

    Bicipital tendinitis is a common cause of anterior shoulder pain, but there is no evidence that acute inflammation of the extra-articular long head of the biceps (LHB) tendon is the root cause of this condition. We evaluated the histologic findings of the extra-articular portion of the LHB tendon and synovial sheath in order to compare those findings to known histologic changes seen in other tendinopathies. Twenty-six consecutive patients (mean age 45.4±13.7 years) underwent an open subpectoral biceps tenodesis for anterior shoulder pain localized to the bicipital groove. Excised tendons were sent for histologic analysis. Specimens were graded using a semiquantitative scoring system to evaluate tenocyte morphology, the presence of ground substance, collagen bundle characteristics, and vascular changes. Chronic inflammation was noted in only two of 26 specimens, and no specimen demonstrated acute inflammation. Tenocyte enlargement and proliferation, characterized by increased roundness and size of the cell and nucleus with proteoglycan matrix expansion and myxoid degenerative changes, was found in all 26 specimens. Abundant ground substance, collagen bundle changes, and increased vascularization were visualized in all samples. Anterior shoulder pain attributed to the biceps tendon does not appear to be due to an inflammatory process in most cases. The histologic findings of the extra-articular portion of the LHB tendon and synovial sheath are similar to the pathologic findings in de Quervain tenosynovitis at the wrist, and may be due to a chronic degenerative process similar to this and other tendinopathies of the body.

  7. Complete rupture of the long head of the biceps tendon and the distal biceps tendon

    Directory of Open Access Journals (Sweden)

    Pieter J. Oberholzer

    2014-12-01

    Full Text Available The most common injury to the biceps muscle is rupture of the long head of the biceps tendon. A tear can occur proximally, distally or at the musculotendinous junction. Two cases are discussed, in both of which the patients felt a sudden sharp pain in the upper arm, at the shoulder and elbow respectively, and presented with a biceps muscle bump (Popeye deformity.

  8. Tendon sheath fibroma in the thigh.

    Science.gov (United States)

    Moretti, Vincent M; Ashana, Adedayo O; de la Cruz, Michael; Lackman, Richard D

    2012-04-01

    Tendon sheath fibromas are rare, benign soft tissue tumors that are predominantly found in the fingers, hands, and wrists of young adult men. This article describes a tendon sheath fibroma that developed in the thigh of a 70-year-old man, the only known tendon sheath fibroma to form in this location. Similar to tendon sheath fibromas that develop elsewhere, our patient's lesion presented as a painless, slow-growing soft tissue nodule. Physical examination revealed a firm, nontender mass with no other associated signs or symptoms. Although the imaging appearance of tendon sheath fibromas varies, our patient's lesion appeared dark on T1- and bright on T2-weighted magnetic resonance imaging. It was well marginated and enhanced with contrast.Histologically, tendon sheath fibromas are composed of dense fibrocollagenous stromas with scattered spindle-shaped fibroblasts and narrow slit-like vascular spaces. Most tendon sheath fibromas can be successfully removed by marginal excision, although 24% of lesions recur. No lesions have metastasized. Our patient's tendon sheath fibroma was removed by marginal excision, and the patient remained disease free 35 months postoperatively. Despite its rarity, tendon sheath fibroma should be included in the differential diagnosis of a thigh mass on physical examination or imaging, especially if it is painless, nontender, benign appearing, and present in men. Copyright 2012, SLACK Incorporated.

  9. Disorders of the long head of the biceps tendon.

    Science.gov (United States)

    Sethi, N; Wright, R; Yamaguchi, K

    1999-01-01

    Without a clear understanding of the functional role of the biceps tendon, treatment recommendations have been a subject of controversy. An objective review of the available information would suggest that some humeral head stability may be imparted through the tendon. However, the magnitude of this function is likely to be small and possibly insignificant. In contrast, the symptomatic significance of the long head of the biceps is less controversial, and it has become increasingly recognized as an important source of persistent shoulder pain when not specifically addressed. When present, persistent pain from the long head of the biceps is likely to have more negative functional consequences than loss of the tendon itself. Given these concerns, evaluation and treatment of patients with long head of the biceps disorders should be individualized, based on the likelihood that biceps-related pain will resolve. Although not universally accepted, we recommend tenodesis of the long head of the biceps in those cases in which there are either chronic inflammatory or structural changes, which would make it unlikely that the pain would resolve. These clinical situations in which tenodesis would be required include greater than 25% partial thickness tearing of the tendon, chronic atrophic changes of the tendon, any luxation of the biceps tendon from the bicipital groove, any disruption of associated bony or ligamentous anatomy of the bicipital groove that would make autotenodesis likely (i.e., 4-part fracture), and any significant reduction or atrophy of the size of the tendon that is more than 25% of the normal tendon width. Relative indications for biceps tenodesis also include biceps disease in the context of a failed decompression for rotator cuff tendinitis. It should be emphasized that routine tenodesis is not recommended during operative treatment for the rotator cuff. Rather, we avoid tenodesis whenever it is believed that inflammatory changes to the biceps tendon are

  10. Surgical treatment of distal biceps tendon rupture: a case report

    Directory of Open Access Journals (Sweden)

    Cristina N. Cozma

    2017-11-01

    Full Text Available Objectives. Distal biceps tendon rupture affects the functional upperextremity movement, impairing supination and flexion strength. According to age, profession and additional risks treatment might be nonoperative or surgical. Methods. We describe the case of a 43 years old male patient who sustained an injury to his right distal biceps and was diagnosed with acute right distal biceps rupture. Surgical treatment was decided and biceps tendon was reinserted to the radius tuberosity using a combination of a cortical button fixation associated with an interference screw. Results. Postoperative functional result was favorable with no complications and with no movement limitation after one month. Conclusions. When possible, distal biceps tendon repair should be realized surgically because this permits restoring of the muscle strength to near normal levels with no loss of motion. Nerve complications are common; therefore the surgery should be realized by experienced upper extremity surgeons.

  11. Surgical treatment of partial biceps tendon ruptures at the elbow.

    Science.gov (United States)

    Dellaero, David T; Mallon, William J

    2006-01-01

    We present the treatment and results of a consecutive series of 7 patients (mean age, 42.7 years) with partial ruptures of the distal biceps tendon. All injuries occurred as the result of either heavy labor or weightlifting. Diagnosis in all cases was made with magnetic resonance imaging. After failure of conservative therapy, the patients were treated with repair of the distal biceps tendon. Mean follow-up was 30.6 months (range, 25-39 months). Results were uniformly good, with all patients satisfied with the outcome. All patients maintained their preoperative range of motion, with none reporting significant postoperative pain. The only complication was transient neurapraxias of the lateral antebrachial cutaneous nerve in 2 cases. We conclude that patients presenting with chronic pain in the cubital fossa should be evaluated for possible partial biceps tendon tear. If the diagnosis of partial tendon tear is made, surgical repair is a safe and effective method of treatment.

  12. Miscellaneous conditions of tendons, tendon sheaths, and ligaments.

    Science.gov (United States)

    Dyson, S J; Dik, K J

    1995-08-01

    The use of diagnostic ultrasonography has greatly enhances our ability to diagnose injuries of tendons and tendon sheaths that were previously either unrecognized or poorly understood. For may of these injuries, there is currently only a small amount of follow-up data. This article considers injuries of the deep digital flexor tendon and its accessory ligament, the carpal tunnel syndrome soft tissue swellings on the dorsal aspect of the carpus, intertubercular (bicipital) bursitis and bicipital tendinitis, injuries of the gastrocnemius tendon, common calcaneal tendinitis, rupture of peroneus (fibularis tertius) and ligaments injuries of the back.

  13. Tendinopathy of the long head of the biceps tendon: histopathologic analysis of the extra-articular biceps tendon and tenosynovium

    OpenAIRE

    Shishani, Yousef; Streit,Jonathan; Rodgers,Mark; Gobezie,Reuben

    2015-01-01

    Jonathan J Streit,1 Yousef Shishani,1 Mark Rodgers,2 Reuben Gobezie1 1The Cleveland Shoulder Institute, 2Department of Pathology, University Hospitals of Cleveland, Cleveland, OH, USA Background: Bicipital tendinitis is a common cause of anterior shoulder pain, but there is no evidence that acute inflammation of the extra-articular long head of the biceps (LHB) tendon is the root cause of this condition. We evaluated the histologic findings of the extra-articular portion of the LHB tendon an...

  14. Osteocalcin expressing cells from tendon sheaths in mice contribute to tendon repair by activating Hedgehog signaling

    OpenAIRE

    Wang, Yi; Zhang, Xu; Huang, Huihui; Xia, Yin; Yao, YiFei; Mak, Arthur Fuk-Tat; Yung, Patrick Shu-Hang; Chan, Kai-Ming; Wang, Li; Zhang, Chenglin; Huang, Yu; Mak, Kingston King-Lun

    2017-01-01

    Both extrinsic and intrinsic tissues contribute to tendon repair, but the origin and molecular functions of extrinsic tissues in tendon repair are not fully understood. Here we show that tendon sheath cells harbor stem/progenitor cell properties and contribute to tendon repair by activating Hedgehog signaling. We found that Osteocalcin (Bglap) can be used as an adult tendon-sheath-specific marker in mice. Lineage tracing experiments show that Bglap-expressing cells in adult sheath tissues pos...

  15. Simultaneous bilateral distal biceps tendon repair: case report

    Directory of Open Access Journals (Sweden)

    Thiago Medeiros Storti

    Full Text Available ABSTRACT Simultaneous bilateral rupture of the distal biceps tendon is a rare clinical entity, seldom reported in the literature and with unclear therapeutic setting. The authors report the case of a 39-year-old white man who suffered a simultaneous bilateral rupture while working out. When weightlifting with elbows at 90° of flexion, he suddenly felt pain on the anterior aspect of the arms, coming for evaluation after two days. He presented bulging contour of the biceps muscle belly and ecchymosis in the antecubital fossa, extending distally to the medial aspect of the forearm, as well as a marked decrease of supination strength and pain in active elbow flexion. MRI confirmed the rupture with retraction of the distal biceps bilaterally. The authors opted for performing the tendon repairs simultaneously through the double incision technique and fixation to the bicipital tuberosity with anchors. The patient progressed quite well, with full return to labor and sports activities, being satisfied with the result after two years of surgery. In the literature search, few reports of simultaneous bilateral rupture of the distal biceps were retrieved, with only one treated in the acute phase of injury. Therefore, the authors consider this procedure to be a good option to solve this complex condition.

  16. Simultaneous bilateral distal biceps tendon repair: case report.

    Science.gov (United States)

    Storti, Thiago Medeiros; Paniago, Alexandre Firmino; Faria, Rafael Salomon Silva

    2017-01-01

    Simultaneous bilateral rupture of the distal biceps tendon is a rare clinical entity, seldom reported in the literature and with unclear therapeutic setting. The authors report the case of a 39-year-old white man who suffered a simultaneous bilateral rupture while working out. When weightlifting with elbows at 90° of flexion, he suddenly felt pain on the anterior aspect of the arms, coming for evaluation after two days. He presented bulging contour of the biceps muscle belly and ecchymosis in the antecubital fossa, extending distally to the medial aspect of the forearm, as well as a marked decrease of supination strength and pain in active elbow flexion. MRI confirmed the rupture with retraction of the distal biceps bilaterally. The authors opted for performing the tendon repairs simultaneously through the double incision technique and fixation to the bicipital tuberosity with anchors. The patient progressed quite well, with full return to labor and sports activities, being satisfied with the result after two years of surgery. In the literature search, few reports of simultaneous bilateral rupture of the distal biceps were retrieved, with only one treated in the acute phase of injury. Therefore, the authors consider this procedure to be a good option to solve this complex condition.

  17. Systematics of injuries of the rotator cuff and biceps tendon

    International Nuclear Information System (INIS)

    Breitenseher, M.J.; Pones, M.; Breitenseher, J.B.

    2015-01-01

    Injuries of the rotator cuff and the biceps tendon demonstrate different patterns, which can be recognized clinically and radiologically. These patterns are impingement syndrome with additional trauma, isolated trauma of the rotator cuff and shoulder dislocation causing rotator cuff tears. Furthermore, it is clinically crucial to evaluate the extent of a rotator cuff injury. Magnetic resonance imaging (MRI) is the modality of choice to differentiate these patterns. (orig.) [de

  18. Ultrasound demonstration of distal biceps tendon bifurcation: normal and abnormal findings

    International Nuclear Information System (INIS)

    Tagliafico, Alberto; Capaccio, Enrico; Derchi, Lorenzo E.; Martinoli, Carlo; Michaud, Johan

    2010-01-01

    We demonstrate the US appearance of the distal biceps tendon bifurcation in normal cadavers and volunteers and in those affected by various disease processes. Three cadaveric specimens, 30 normal volunteers, and 75 patients were evaluated by means of US. Correlative MR imaging was obtained in normal volunteers and patients. In all cases US demonstrated the distal biceps tendon shaped by two separate tendons belonging to the short and long head of the biceps brachii muscle. Four patients had a complete rupture of the distal insertion of the biceps with retraction of the muscle belly. Four patients had partial tear of the distal biceps tendon with different US appearance. In two patients the partial tear involved the short head of the biceps brachii tendon, while in the other two patients, the long head was involved. Correlative MR imaging is also presented both in normal volunteers and patients. US changed the therapeutic management in the patients with partial tears involving the LH of the biceps. This is the first report in which ultrasound considers the distal biceps tendon bifurcation in detail. Isolated tears of one of these components can be identified by US. Knowledge of the distal biceps tendon bifurcation ultrasonographic anatomy and pathology has important diagnostic and therapeutic implications. (orig.)

  19. Contrast material filling of the peroneal tendon sheath

    International Nuclear Information System (INIS)

    Zadravecz, Gy.; Grexa, E.

    1981-01-01

    In case of complaints after fracture of the calcaneus the common sheath of the peroneus tendons was filled up with contrast material. The tendon sheath was punctured Oehind the external ankle. The three-directional radiograms clearly showed the dislocation and compression of the tendons, caused by the exostosis of the calcaneus. The concomitant tendovaginitis caused the complaints. This alteration was observed in 11% of all the calcaneus fractures. (L.E.)

  20. Bilateral congenital absence of the long head of the biceps tendon

    Energy Technology Data Exchange (ETDEWEB)

    Koplas, Monica C. [Cleveland Clinic, Imaging Institute/HB6, Cleveland, OH (United States); Winalski, Carl S. [Cleveland Clinic, Imaging Institute/A21, Cleveland, OH (United States); Ulmer, William H. [Orthopedic and Spine Specialists, York, PA (United States); Recht, Michael [NYU Langone Medical Center, Department of Radiology, New York, NY (United States)

    2009-07-15

    Absence of the long head of the biceps tendon is a rare anomaly particularly when it occurs bilaterally. We present the magnetic resonance and arthroscopy findings in a patient with bilateral congenital absence of the long head of the biceps who presented with bilateral shoulder pain. Identification of a shallow or absent intertubercular groove may aid in differentiating congenital absence of the long head of the biceps from a traumatic tendon rupture. (orig.)

  1. Bilateral giant cell tumor of tendon sheath of tendoachilles

    Directory of Open Access Journals (Sweden)

    Soma Datta

    2014-01-01

    Full Text Available Giant cell tumor of tendon sheath arises from the synovium of tendon sheaths, joints, or bursae, mostly affects adults between 30 and 50 years of age, and is slightly more common in females. We report the case of a 32-years-old male presenting with pain in both ankles without any history of trauma. On clinical examination, tenderness on both tendoachilles and local thickening were observed. Ultrasonography showed thickening of local tendinous area with increase in anteroposterior diameter, and Doppler demonstrated increased flow in peritendinous area. MRI findings showed that most of the tumor had intermediate signal intensity and portions of the tumor had low signal intensity. Fine needle aspiration cytology confirmed the diagnosis of giant cell tumor of tendon sheath. Excision biopsy was done with no recurrence on five month follow-up. Review of literature did not reveal any similar result; so, bilateral giant cell tumor of tendon sheath of tendoachilles is a rare presentation.

  2. Repair of the torn distal biceps tendon by endobutton fixation

    Directory of Open Access Journals (Sweden)

    Ravi K Gupta

    2012-01-01

    Full Text Available Background: A number of techniques have been described to reattach the torn distal biceps tendon to the bicipital tuberosity. We report a retrospective analysis of single incision technique using an endobutton fixation in sports persons. Materials and Methods: The present series include nine torn distal biceps tendons in eight patients, fixed anatomically to the radial tuberosity with an endobutton by using a single incision surgical technique; seven patients had suffered the injuries during contact sports. The passage of the endobutton was facilitated by using a blunt tipped pin in order to avoid injury to the posterior interosseous nerve. The patients were evaluated by Disabilities of the Arm, Shoulder and Hand (DASH score and Mayo elbow score. Results: The average age of the patients was 27.35 years (range 21-42 years. Average follow-up was 41.5 months (range 24-102 months. The final average flexion extension arc was 0°-143°, while the average pronation and supination angles were 77° (range 70°-82° and 81° (range 78°-85°, respectively at the last followup. All the patients had a Disabilities of the Arm, Shoulder and Hand (DASH score of 0 and a Mayo elbow score of 100 each. All the seven active sports persons were able to get back to their respective game. There was no nerve injury or any other complication. Conclusions: The surgical procedure used by us is a simple, safe and reproducible technique giving minimal morbidity and better cosmetic results.

  3. An investigation of tendon sheathing filler migration into concrete

    International Nuclear Information System (INIS)

    Naus, D.J.; Oland, C.B.

    1998-03-01

    During some of the inspections at nuclear power plants with prestressed concrete containments, it was observed that the containments has experienced leakage of the tendon sheathing filler (i.e., streaks). The objective of this activity was to provide an indication of the extent of tendon sheathing filler leakage into the concrete and its affects on concrete properties. Literature was reviewed and concrete core samples were obtained from the Trojan Nuclear Plant and tested. The literature primarily addressed effects of crude or lubricating oils that are known to cause concrete damage. However, these materials have significantly different characteristics relative to the materials used as tendon sheathing fillers. Examination and testing of the concrete cores indicated that the appearance of tendon sheathing filler on the concrete surface was due to leakage from the conduits and its subsequent migration through cracks that were present. Migration of the tendon sheathing filler was confined to the cracks and there was no perceptible movement into the concrete. Results of compressive strength testing indicated that the concrete quality was consistent in the containment and that the strength had increased over 40% in 25.4 years relative to the average compressive strength at 28-days age

  4. Diagnosis and treatment of biceps tendinitis and tendinosis.

    Science.gov (United States)

    Churgay, Catherine A

    2009-09-01

    Biceps tendinitis is inflammation of the tendon around the long head of the biceps muscle. Biceps tendinosis is caused by degeneration of the tendon from athletics requiring overhead motion or from the normal aging process. Inflammation of the biceps tendon in the bicipital groove, which is known as primary biceps tendinitis, occurs in 5 percent of patients with biceps tendinitis. Biceps tendinitis and tendinosis are commonly accompanied by rotator cuff tears or SLAP (superior labrum anterior to posterior) lesions. Patients with biceps tendinitis or tendinosis usually complain of a deep, throbbing ache in the anterior shoulder. Repetitive overhead motion of the arm initiates or exacerbates the symptoms. The most common isolated clinical finding in biceps tendinitis is bicipital groove point tenderness with the arm in 10 degrees of internal rotation. Local anesthetic injections into the biceps tendon sheath may be therapeutic and diagnostic. Ultrasonography is preferred for visualizing the overall tendon, whereas magnetic resonance imaging or computed tomography arthrography is preferred for visualizing the intra-articular tendon and related pathology. Conservative management of biceps tendinitis consists of rest, ice, oral analgesics, physical therapy, or corticosteroid injections into the biceps tendon sheath. Surgery should be considered if conservative measures fail after three months, or if there is severe damage to the biceps tendon.

  5. Mineralized fibroma of the tendon sheath presenting as a bursitis

    Energy Technology Data Exchange (ETDEWEB)

    Le Corroller, Thomas; Champsaur, Pierre [Hopital Sainte-Marguerite, Service de Radiologie, Marseille (France); Faculte de Medecine de Marseille, Departement d' Anatomie, Marseille (France); Bouvier-Labit, Corinne [Hopital La Timone, Service d' Anatomopathologie, Marseille (France); Sbihi, Abderrahmane [Clinique Juge, Service de Chirurgie orthopedique, Marseille (France)

    2008-12-15

    We report on the clinical, imaging - including ultrasound, computed tomography, and magnetic resonance imaging - and histological features of a fibroma of the tendon sheath with mineralized chondroid and osseous metaplasia, presenting as a semimembranosus bursitis. The anatomical characteristics of the semimembranosus bursa are demonstrated by dissection in a cadaveric specimen and correlated with the imaging findings in our patient. (orig.)

  6. Mineralized fibroma of the tendon sheath presenting as a bursitis

    International Nuclear Information System (INIS)

    Le Corroller, Thomas; Champsaur, Pierre; Bouvier-Labit, Corinne; Sbihi, Abderrahmane

    2008-01-01

    We report on the clinical, imaging - including ultrasound, computed tomography, and magnetic resonance imaging - and histological features of a fibroma of the tendon sheath with mineralized chondroid and osseous metaplasia, presenting as a semimembranosus bursitis. The anatomical characteristics of the semimembranosus bursa are demonstrated by dissection in a cadaveric specimen and correlated with the imaging findings in our patient. (orig.)

  7. Brachial biceps tendon injuries in young female high-level tennis players.

    Science.gov (United States)

    Tsur, A; Gillson, S

    2000-06-01

    To evaluate brachial biceps tendon lesions in four young female tennis players who complained about anterior shoulder pain on their dominant side. Medical and sport's activity history, palpation of the painful zone, Ghilchrist (palm-up) test, and brachial biceps contraction against resistance were performed. The two girls who suffered from mild tenderness in the bicipital groove and over the anterior aspect of the upper arm and the shoulder joint, had tendinitis of the long biceps head. The two girls who suffered from severe tenderness just under the groove, had a partial tear in the long head of the biceps. Ghilchrist test was positive in all girls. Tennis players can have shoulder pain without clear history of trauma. Pain occurred probably as a result of technical errors or use of inadequate equipment.

  8. Partial tears of the distal biceps tendon: MR appearance and associated clinical findings

    Energy Technology Data Exchange (ETDEWEB)

    Williams, B.D.; Schweitzer, M.E.; Weishaupt, D.; Miller, L.S. [Thomas Jefferson Univ., Philadelphia, PA (United States). Dept. of Radiology; Lerman, J. [Lerman Imaging, Brooklyn, NY (United States); Rubenstein, D.L. [Orthopaedic Surgery, Thomas Jefferson University Hospital, Philadelphia, PA (United States); Rosenberg, Z.S. [Dept. of Diagnostic Radiology, New York Univ. Medical Center, NY (United States)

    2001-10-01

    Purpose: To describe the magnetic resonance (MR) appearance and associated clinical findings of partial distal biceps tendon tears. Design: Twenty elbow MR images at 1.5 T, performed over a 7 year period, were reviewed for an appearance of partial tears in the distal biceps. These images were assessed by two musculoskeletal radiologists for the extent of: (a) abnormal signal intensity within the tendon, and the presence of (b) bicipitoradial bursitis, and (c) bony microavulsive injury of the radial tuberosity. Medical records for nine of the 20 cases were reviewed for the clinical findings of ecchymosis, trauma, sensation of a ''pop'', loss of function, and acuity of onset. Results: Twenty partial distal biceps tendon tears were seen. All displayed an abnormally increased signal in the distal biceps tendon. Three of 20 (15%) showed a 25% to 50% tear, ten of 20 (50%) showed a 50% tear, and seven of 20 (35%) showed a 75% to 90% tear. Bicipitoradial bursitis was seen in 11 of 20 (55%) cases. Bony microavulsive injury of the radial tuberosity was observed in 10 of 20 (50%). Of the nine cases reviewed for associated clinical findings, surprisingly, only three (33%) experienced an acute traumatic episode with an abrupt onset of pain. An insidious onset was reported in four of nine (44%). Sensation of a ''pop'' was recorded in only two of nine (22%) cases. Ecchymosis and loss of function were not seen in any of the cases. Finally, surgical conformation was obtained for three cases. Conclusion: Partial distal biceps tendon tears have a characteristic MR appearance, demonstrate little functional deficit, and may be attritional in their etiology due to the observation of a low number of patients reporting trauma or an acute onset. (orig.)

  9. Partial tears of the distal biceps tendon: MR appearance and associated clinical findings

    International Nuclear Information System (INIS)

    Williams, B.D.; Schweitzer, M.E.; Weishaupt, D.; Miller, L.S.; Rubenstein, D.L.; Rosenberg, Z.S.

    2001-01-01

    Purpose: To describe the magnetic resonance (MR) appearance and associated clinical findings of partial distal biceps tendon tears. Design: Twenty elbow MR images at 1.5 T, performed over a 7 year period, were reviewed for an appearance of partial tears in the distal biceps. These images were assessed by two musculoskeletal radiologists for the extent of: (a) abnormal signal intensity within the tendon, and the presence of (b) bicipitoradial bursitis, and (c) bony microavulsive injury of the radial tuberosity. Medical records for nine of the 20 cases were reviewed for the clinical findings of ecchymosis, trauma, sensation of a ''pop'', loss of function, and acuity of onset. Results: Twenty partial distal biceps tendon tears were seen. All displayed an abnormally increased signal in the distal biceps tendon. Three of 20 (15%) showed a 25% to 50% tear, ten of 20 (50%) showed a 50% tear, and seven of 20 (35%) showed a 75% to 90% tear. Bicipitoradial bursitis was seen in 11 of 20 (55%) cases. Bony microavulsive injury of the radial tuberosity was observed in 10 of 20 (50%). Of the nine cases reviewed for associated clinical findings, surprisingly, only three (33%) experienced an acute traumatic episode with an abrupt onset of pain. An insidious onset was reported in four of nine (44%). Sensation of a ''pop'' was recorded in only two of nine (22%) cases. Ecchymosis and loss of function were not seen in any of the cases. Finally, surgical conformation was obtained for three cases. Conclusion: Partial distal biceps tendon tears have a characteristic MR appearance, demonstrate little functional deficit, and may be attritional in their etiology due to the observation of a low number of patients reporting trauma or an acute onset. (orig.)

  10. In vivo engineering of a functional tendon sheath in a hen model.

    Science.gov (United States)

    Xu, Liang; Cao, Dejun; Liu, Wei; Zhou, Guangdong; Zhang, Wen Jie; Cao, Yilin

    2010-05-01

    Repair of injured tendon sheath remains a major challenge and this study explored the possibility of in vivo reconstruction of a tendon sheath with tendon sheath derived cells and polyglycolic acid (PGA) fibers in a Leghorn hen model. Total 55 Leghorn hens with a 1cm tendon sheath defect created in the left middle toe of each animal were randomly assigned into: (1) experimental group (n=19) that received a cell-PGA construct; (2) scaffold control group (n=18) that received a cell-free PGA scaffold; (3) blank control group (n=18) with the defect untreated. Tendon sheath cells were isolated, in vitro expanded, and seeded onto PGA scaffolds. After in vitro culture for 7 days, the constructs were in vivo implanted to repair the sheath defects. Alcian blue staining confirmed the ability of cultured cells to produce specific matrices containing acidic carboxyl mucopolysaccharide (mainly hyaluronic acid). In addition, the engineered sheath formed a relatively mature structure at 12 weeks post-surgery, which was similar to that of native counterpart, including a smooth inner surface, a well-developed sheath histological structure with a clear space between the tendon and the engineered sheath. More importantly, Work of Flexion assay revealed that the tendons needed less power consumption to glide inside the engineered sheath when compared to the tendons which were surrounded by scar-repaired tissues, indicating that the engineered sheaths had gained the function to a certain extent of preventing tendon adhesion. Taken together, these results suggest that tendon sheaths that are functionally and structurally similar to native sheaths are possible to be engineered in vivo using tendon sheath cells and PGA scaffolds. Copyright 2010 Elsevier Ltd. All rights reserved.

  11. Degeneration of the long biceps tendon: comparison of MRI with gross anatomy and histology.

    Science.gov (United States)

    Buck, Florian M; Grehn, Holger; Hilbe, Monika; Pfirrmann, Christian W A; Manzanell, Silvana; Hodler, Jürg

    2009-11-01

    The objective of our study was to relate alterations in biceps tendon diameter and signal on MR images to gross anatomy and histology. T1-weighted, T2-weighted fat-saturated, and proton density-weighted fat-saturated spin-echo sequences were acquired in 15 cadaveric shoulders. Biceps tendon diameter (normal, flattened, thickened, and partially or completely torn) and signal intensity (compared with bone, fat, muscle, and joint fluid) were graded by two readers independently and in a blinded fashion. The distance of tendon abnormalities from the attachment at the glenoid were noted in millimeters. MRI findings were related to gross anatomic and histologic findings. On the basis of gross anatomy, there were six normal, five flattened, two thickened, and two partially torn tendons. Reader 1 graded nine diameter changes correctly, missed two, and incorrectly graded four. The corresponding values for reader 2 were seven, one, and five, respectively, with kappa = 0.75. Histology showed mucoid degeneration (n = 13), lipoid degeneration (n = 7), and fatty infiltration (n = 6). At least one type of abnormality was found in each single tendon. Mucoid degeneration was hyperintense compared with fatty infiltration on T2-weighted fat-saturated images and hyperintense compared with magic-angle artifacts on proton density-weighted fat-saturated images. MRI-based localization of degeneration agreed well with histologic findings. Diameter changes are specific but not sensitive in diagnosing tendinopathy of the biceps tendon. Increased tendon signal is most typical for mucoid degeneration but should be used with care as a sign of tendon degeneration.

  12. Free Biceps Tendon Autograft to Augment Arthroscopic Rotator Cuff Repair

    OpenAIRE

    Obma, Padraic R.

    2013-01-01

    Arthroscopic rotator cuff repairs have become the standard of treatment for all sizes of tears over the past several years. Current healing rates reported in the literature are quite good, but improving the healing potential of rotator cuff repairs remains a challenging problem. There has been an increase recently in the use of augmentation of rotator cuff repairs with xenografts or synthetics for large and massive tears. Biceps tenodesis is often indicated as part of the treatment plan while...

  13. Simultaneous bilateral distal biceps tendon rupture during a preacher curl exercise: a case report.

    Science.gov (United States)

    Rokito, Andrew S; lofin, Ilya

    2008-01-01

    Complete rupture of the distal biceps tendon is a rare injury, the overwhelming majority occurring in the dominant arm of males during the fourth to sixth decades of life. Simultaneous bilateral rupture of the distal biceps tendon is an extremely rare occurrence, with only three cases reported in the literature. This unusual injury occurred in a recreational weightlifter during a preacher curl exercise. In this particular case, a 6-week delay in presentation necessitated a staged procedure in which a primary repair was feasible in one elbow, while reconstruction using allograft tissue was required in the contralateral elbow. Satisfactory results for both elbows were achieved, with return to weightlifting by one year following surgery.

  14. Evaluation of the equine digital flexor tendon sheath using diagnostic ultrasound and contrast radiography

    International Nuclear Information System (INIS)

    Redding, W.R.

    1994-01-01

    This study was designed to evaluate the normal anatomy of the digital flexor tendon sheath using contrast radiography and diagnostic ultrasound. Iodinated contrast medium was injected into eight cadaver limbs and the limbs immediately frozen. Lateromedial and dorsopalmar/plantar radiographs were made. These limps were then cut transversely and proximal to distal radiographs of each slab were made. This cross sectional contrast methodology allowed the visualization of the relative size and shape of the superficial and deep digital flexor tendons as well as the potential space taken by effusions of the digital flexor tendon sheath. The second part of the study used twelve live animals with normal digital flexor tendon sheaths. Ultrasonographic measurement of the structures of the digital flexor tendon sheath at each level were compiled. This documented the ability of diagnostic ultrasound to image: 1) the superficial and deep digital flexor tendons, 2) the proximal and distal ring of the manica flexoria, 3) the straight and oblique sesamoidean ligaments, and 4) the mesotendinous attachments to the superficial and deep flexor tendons. Iodinated contrast medium was then injected into the digital flexor tendon sheath and the ultrasonography repeated. These images were compared with those obtained from contrast radiography and prosections of twenty normal limbs. The iodinated contrast medium enhanced sonographic imaging of the structures of the digital tendon sheath, particularly the abaxial borders of the superficial digital flexor tendon branches and the mesotendinous attachments to the superficial and deep digital flexor tendons

  15. Tendon patch grafting using the long head of the biceps for irreparable massive rotator cuff tears

    International Nuclear Information System (INIS)

    Sano, Hirotaka; Itoi, Eiji; Mineta, Mitsuyoshi; Kita, Atsushi

    2010-01-01

    Surgical treatment of massive rotator cuff tears is challenging for shoulder surgeons. The purpose of this study was to investigate both clinical outcomes and cuff integrity after tendon patch grafting using the long head of the biceps (LHB) tendon for irreparable massive rotator cuff tears. A short deltoid splitting approach was used to expose the torn cuff tendon stump. After tenodesis of the LHB tendon, its intraarticular portion was resected. If the size of the harvested tendon was smaller than that of the cuff defect, it was split into two layers. Then, the LHB tendon was sutured to the remnant cuff tendons and fixed to the footprint using the transosseous suture technique. A total of 14 patients (12 men, 2 women; average age 64 years) underwent this procedure. The average postoperative follow-up period was 28 months (range 12-51 months). Active elevation angle of the shoulder as well as the Japanese Orthopaedic Association (JOA) score were assessed before surgery and at the time of follow-up. Postoperative cuff integrity was assessed using T2-weighted magnetic resonance imaging (MRI). All cuff defects were successfully closed with this technique. Average active elevation angle improved from 69deg to 149deg. Total JOA score also improved from 54.7 points to 83.1 points. Thirteen shoulders showed no re-tearing on T2-weighted MRI; a minor discontinuity of the repaired cuff tendon was observed in the other shoulder. The LHB tendon is available in case tenodesis or tenotomy is needed. The resected tendon may be used as a graft for rotator cuff repair without any additional skin incision, which could reduce both the surgical invasion and the risk of infection. The LHB tendon patch grafting may be one of the useful options for surgical treatment of irreparable massive rotator cuff tears. (author)

  16. Assessment of instability of the long head of the biceps tendon by MRI

    International Nuclear Information System (INIS)

    Spritzer, C.E.; Collins, A.J.; Cooperman, A.; Speer, K.P.

    2001-01-01

    Objective. To determine whether MRI can identify instability of the long head of the biceps tendon (LBT) in the rotator interval.Design and patients. A retrospective review was carried out of 19 patients, all arthroscopically examined, nine of whom had surgically confirmed instability of the LBT.Results. A LBT perched on the lesser tuberosity correctly indicated all nine cases of instability with one false positive. In six of seven cases where the LBT was oval in shape, no instability of the biceps tendon existed, whereas LBT instability was present in eight of 12 patients with a flat long head of the biceps tendon. In seven of eight acutely angled intertubercular sulci there was no instability of the LBT while eight of 11 obtusely angled sulci were associated with LBT instability. By consensus impression, instability of the LBT could be determined with 67% sensitivity, 90% specificity, 86% positive predictive value, and 75% negative predictive value.Conclusions. A flat LBT perched on the lesser tuberosity with an obtusely angled intertubercular sulcus suggests the diagnosis of instability of the LBT in the correct clinical setting. (orig.)

  17. Normal tendon sheath of the second to fifth fingers as seen on oblique views

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, E.

    1984-01-01

    Oblique views of the fingers, using a low kilovolt technique, show a portion of the tendon sheaths which can be regarded as representative of the entire sheath. Because of the varying obliquity of each finger, this proportion differs in the fingers. With increasing age the projected portion of the sheath becomes smaller because it is covered by increasing bone formation in the insertion of the tendon sheat. Normal values have been obtained for adults according to their decades; from these, quite minor degrees of tendon sheat thickening can be determined. In camptodactyly of the fifth finger, which is not uncommon, the tendon sheat may be widened in the absence of a tenosynovitis.

  18. Rupture of the Distal Biceps Tendon Combined with a Supinator Muscle Tear in a 51-Year-Old Woman: A Case Report

    OpenAIRE

    Nayyar, Samir; Quirno, Martin; Hasan, Saqib; Rybak, Leon; Meislin, Robert J.

    2011-01-01

    Distal biceps tendon rupture is a relatively uncommon occurrence in the general female population, and to our knowledge, has not been reported in association with a supinator muscle tear. We report a case of 51-year-old woman who experienced sharp pain in her forearm and elbow after lifting a heavy object. History and physical examination raised suspicion for a distal biceps tendon rupture. MRI imaging determined a combined distal biceps tendon tear with a supinator muscle tear with subsequen...

  19. Rupture of the long tendon of the biceps brachi muscle. An unusual case related to use of the pneumatic tourniquet.

    Science.gov (United States)

    Logel, R J

    1976-01-01

    Tourniquet paralysis, arterial spasm, aneurysm formation, and the post-ischemic hand syndrome are all complications of penumatic tourniquet use in surgery of the extremities. This is a case report of another complication of tourniquet use, rupture of the long tendon of the biceps brachii muscle. Some underlying pathologic or degenerative condition usually exists before rupture can occur. Both rheumatoid arthritis and local corticosteroid injections into the long tendon of the biceps probably accounted for weakening the tensile strength of the tendon and subsequent rupture in the case described.

  20. Rupture of the Distal Biceps Tendon Combined with a Supinator Muscle Tear in a 51-Year-Old Woman: A Case Report

    Directory of Open Access Journals (Sweden)

    Samir Nayyar

    2011-01-01

    Full Text Available Distal biceps tendon rupture is a relatively uncommon occurrence in the general female population, and to our knowledge, has not been reported in association with a supinator muscle tear. We report a case of 51-year-old woman who experienced sharp pain in her forearm and elbow after lifting a heavy object. History and physical examination raised suspicion for a distal biceps tendon rupture. MRI imaging determined a combined distal biceps tendon tear with a supinator muscle tear with subsequent confirmation at surgery. Surgical repair was performed for the distal biceps tendon only through a single incision approach using the Endobutton technique.

  1. Giant Cell Tumour of Tendon Sheath Masquerading As Trigger Finger

    Directory of Open Access Journals (Sweden)

    N Rahimawati

    2010-11-01

    Full Text Available We report a case of a 59-year-old female who presented in the general orthopaedic clinic with triggering of her right middle finger. She did not respond to conventional treatment methods; subsequently she underwent surgical open release under local anaesthesia. Five months postoperatively, the patient presented with signs and symptoms of acute flexor tenosynovitis, and was thought to have a postoperative infection. Re-examination by a hand surgeon raised the possibility of a different aetiology. Based on clinical findings and response to initial treatment, giant cell tumour of the flexor tendon sheath was suspected and later confirmed following surgical biopsy. A high index of suspicion and knowledge of the variegated presentations of giant cell tumour in the hand are beneficial in these types of cases.

  2. Rupture Following Biceps-to-Triceps Tendon Transfer in Adolescents and Young Adults With Spinal Cord Injury:

    Science.gov (United States)

    Merenda, Lisa A.; Rutter, Laure; Curran, Kimberly; Kozin, Scott H.

    2012-01-01

    Background: Tendon transfer surgery can restore elbow extension in approximately 70% of persons with tetraplegia and often results in antigravity elbow extension strength. However, we have noted an almost 15% rupture/attenuation rate. Objective: This investigation was conducted to analyze potential causes in adolescents/young adults with spinal cord injury (SCI) who experienced tendon rupture or attenuation after biceps-to-triceps transfer. Methods: Medical charts of young adults with SCI who underwent biceps-to-triceps transfer and experienced tendon rupture or attenuation were reviewed. Data collected by retrospective chart review included general demographics, surgical procedure(s), use and duration of antibiotic treatment, time from tendon transfer surgery to rupture/attenuation, and method of diagnosis. Results: Twelve subjects with tetraplegia (mean age, 19 years) who underwent biceps-to-triceps reconstruction with subsequent tendon rupture or attenuation were evaluated. Mean age at time of tendon transfer was 18 years (range, 14-21 years). A fluoroquinolone was prescribed for 42% (n=5) of subjects. Tendon rupture was noted in 67% (n=8), and attenuation was noted in 33% (n=4). Average length of time from surgery to tendon rupture/attenuation was 5.7 months (range, 3-10 months). Conclusion: Potential contributing causes of tendon rupture/attenuation after transfer include surgical technique, rehabilitation, co-contraction of the transfer, poor patient compliance, and medications. In this cohort, 5 subjects were prescribed fluoroquinolones that have a US Food and Drug Administration black box concerning tendon ruptures. Currently, all candidates for upper extremity tendon transfer reconstruction are counseled on the effects of fluoroquinolones and the potential risk for tendon rupture. PMID:23459326

  3. Diagnostic value of US, CT arthrography, and 0.5-T MR imaging of lesions of the biceps tendon

    International Nuclear Information System (INIS)

    Saez, F.; Elizagaray, E.; Pena, J.M.; Ferrero, A.; Azkuna, I.; Larrea, L.

    1990-01-01

    This paper evaluates the role of US, CT-arthrography, and MR imaging in lesions in the tendon of the long head of the biceps brachii and bicipital groove. One hundred fifty-four patients with painful shoulder were prospectively studied by means of US and axial CT-arthrography, and 45 of them were also examined with 0.5-T MR imaging. Fifty-three (34.4%) patients showed biceps tendon or bicipital groove abnormalities; including 34 bicipital groove bone spurs, 31 cases of tendinitis, eight intraarticular ruptures, four subluxations, and eight medial dislocations

  4. Ganglion of the Flexor Tendon Sheath at the A2 Pulley - Case Report

    Directory of Open Access Journals (Sweden)

    P Gunaseelan

    2015-03-01

    Full Text Available There are few reported cases of flexor tendon sheath ganglion arising from the A2 pulley. We report a case of a flexor tendon sheath ganglion in a 17-year old female who presented with pain, triggering and a swelling at the base of her right ring finger. During the excision biopsy, a ganglion measuring 0.5×0.8×0.4 cm in size was removed from the A2 pulley area.

  5. Augmentation of Distal Biceps Repair With an Acellular Dermal Graft Restores Native Biomechanical Properties in a Tendon-Deficient Model.

    Science.gov (United States)

    Conroy, Christine; Sethi, Paul; Macken, Craig; Wei, David; Kowalsky, Marc; Mirzayan, Raffy; Pauzenberger, Leo; Dyrna, Felix; Obopilwe, Elifho; Mazzocca, Augustus D

    2017-07-01

    The majority of distal biceps tendon injuries can be repaired in a single procedure. In contrast, complete chronic tears with severe tendon substance deficiency and retraction often require tendon graft augmentation. In cases with extensive partial tears of the distal biceps, a human dermal allograft may be used as an alternative to restore tendon thickness and biomechanical integrity. Dermal graft augmentation will improve load to failure compared with nonaugmented repair in a tendon-deficient model. Controlled laboratory study. Thirty-six matched specimens were organized into 1 of 4 groups: native tendon, native tendon with dermal graft augmentation, tendon with an attritional defect, and tendon with an attritional defect repaired with a graft. To mimic a chronic attritional biceps lesion, a defect was created by a complete tear, leaving 30% of the tendon's width intact. The repair technique in all groups consisted of cortical button and interference screw fixation. All specimens underwent cyclical loading for 3000 cycles and were then tested to failure; gap formation and peak load at failure were documented. The mean (±SD) load to failure (320.9 ± 49.1 N vs 348.8 ± 77.6 N, respectively; P = .38) and gap formation (displacement) (1.8 ± 1.4 mm vs 1.6 ± 1.1 mm, respectively; P = .38) did not differ between the native tendon groups with and without graft augmentation. In the tendon-deficient model, the mean load to failure was significantly improved with graft augmentation compared with no graft augmentation (282.1 ± 83.8 N vs 199.7 ± 45.5 N, respectively; P = .04), while the mean gap formation was significantly reduced (1.2 ± 1.0 mm vs 2.7 ± 1.4 mm, respectively; P = .04). The mean load to failure of the deficient tendon with graft augmentation (282.1 N) compared with the native tendon (348.8 N) was not significantly different ( P = .12). This indicates that the native tendon did not perform differently from the grafted deficient tendon. In a tendon

  6. Three-dimensional Doppler ultrasound findings in healthy wrist and finger tendon sheaths

    DEFF Research Database (Denmark)

    Ammitzboll-Danielsen, Mads; Janta, Iustina; Torp-Pedersen, Søren

    2016-01-01

    interpretation of Doppler signals when diagnosing tenosynovitis. Method Forty healthy participants (20 women and 20 men age 23-67 years) without prior history of arthritis, tendon diseases or present pain in their hands were included. Twenty participants had 3D Doppler US of the second and third finger...... participant. No significant difference in feeding vessels was seen between the radial and carpal level in the wrist (p = 0.06) or between the second and third flexor tendon sheath (p = 0.84). Conclusion Doppler findings in or in close proximity to the tendon sheaths were common in wrists and fingers...

  7. REHABILITATION OF A SURGICALLY REPAIRED RUPTURE OF THE DISTAL BICEPS TENDON IN AN ACTIVE MIDDLE AGED MALE: A CASE REPORT

    Science.gov (United States)

    Sayers, Stephen P.; LaFontaine, Tom; Scheussler, Scott

    2012-01-01

    Background: Complete rupture of the distal tendon of the biceps brachii is relatively rare and there is little information to guide therapists in rehabilitation after this injury. The purposes of this case report are to review the rehabilitation concepts used for treating such an injury, and discuss how to modify exercises during rehabilitation based on patient progression while adhering to physician recommended guidelines and standard treatment protocols. Case Presentation: The patient was an active 38‐year old male experienced in weight‐training. He presented with a surgically repaired right distal biceps tendon following an accident on a trampoline adapted with a bungee suspension harness. The intervention focused on restoring range of motion and strengthening of the supporting muscles of the upper extremity without placing undue stress on the biceps brachii. Outcomes: The patient was able to progress from a moderate restriction in ROM to full AROM two weeks ahead of the physician's post‐operative orders and initiate a re‐strengthening protocol by the eighth week of rehabilitation. At the eighth post‐operative week the patient reported no deficits in functional abilities throughout his normal daily activities with his affected upper extremity. Discussion: The results of this case report strengthen current knowledge regarding physical therapy treatment for a distal biceps tendon repair while at the same time providing new insights for future protocol considerations in active individuals. Most current protocols do not advocate aggressive stretching, AROM, or strengthening of a surgically repaired biceps tendon early in the rehabilitation process due to the fear of a re‐rupture. In the opinion of the authors, if full AROM can be achieved before the 6th week of rehabilitation, initiating a slow transition into light strengthening of the biceps brachii may be possible. Level of evidence: 4‐Single Case report PMID:23316429

  8. The normal tendon sheath of the second to fifth fingers as seen on oblique views

    International Nuclear Information System (INIS)

    Fischer, E.

    1984-01-01

    Oblique views of the fingers, using a low kilovolt technique, show a portion of the tendon sheaths which can be regarded as representative of the entire sheath. Because of the varying obliquity of each finger, this proportion differs in the fingers. With increasing age the projected portion of the sheath becomes smaller because it is covered by increasing bone formation in the insertion of the tendon sheat. Normal values have been obtained for adults according to their decades; from these, quite minor degrees of tendon sheat thickening can be determined. In camptodactyly of the fifth finger, which is not uncommon, the tendon sheat may be widened in the absence of a tenosynovitis. (orig.) [de

  9. Slap Lesions in Middle-aged Patients: Biceps Repair or Tenodesis? What Should We Perform for Long Biceps Tendon?

    Directory of Open Access Journals (Sweden)

    Sergi Sastre

    2015-12-01

    Conclusion: Biceps tenodesis is a feasible therapeutic alternative to anatomical repair for the treatment of SLAP lesions in middle-aged patients; the reinsertion failure rates for this type of lesion are rather discouraging due to the high percentage of revision surgeries that must be carried out after the primary intervention.

  10. Floating fat in the wrist joint and in the tendon sheaths

    Energy Technology Data Exchange (ETDEWEB)

    Le Corroller, Thomas; Zink, Jean-Vincent; Champsaur, Pierre [Hopital Sainte-Marguerite, Radiology Department, Marseille (France); Parratte, Sebastien; Argenson, Jean-Noel [Hopital Sainte-Marguerite, Orthopaedic Surgery Department, Marseille (France)

    2010-09-15

    A traumatic fat effusion in a tendon sheath is an unreported entity. We report on the clinical and imaging features, including radiography and computed tomography (CT), of a fat-density effusion in the wrist joint and tendon sheaths of the extensor pollicis longus, extensor carpi radialis longus, and extensor carpi radialis brevis in a 28-year-old patient after a roller-skating accident. Radiographs showed a fracture of the distal radius and a wrist joint effusion. Preoperative CT examination exhibited two distinct layers resulting in a fat-fluid level pathognomonic of lipohemarthrosis in the radiocarpal joint. In addition, a fat-density effusion was noted in the sheaths of the second and third compartment extensor tendons. The lipohemarthrosis depicted on imaging classically results from the extrusion of fat from bone marrow into the joint space after an intraarticular fracture. Similarly, a traumatic fat effusion in a tendon sheath presents characteristic imaging features that may help to diagnose a potentially overlooked fracture. (orig.)

  11. Floating fat in the wrist joint and in the tendon sheaths

    International Nuclear Information System (INIS)

    Le Corroller, Thomas; Zink, Jean-Vincent; Champsaur, Pierre; Parratte, Sebastien; Argenson, Jean-Noel

    2010-01-01

    A traumatic fat effusion in a tendon sheath is an unreported entity. We report on the clinical and imaging features, including radiography and computed tomography (CT), of a fat-density effusion in the wrist joint and tendon sheaths of the extensor pollicis longus, extensor carpi radialis longus, and extensor carpi radialis brevis in a 28-year-old patient after a roller-skating accident. Radiographs showed a fracture of the distal radius and a wrist joint effusion. Preoperative CT examination exhibited two distinct layers resulting in a fat-fluid level pathognomonic of lipohemarthrosis in the radiocarpal joint. In addition, a fat-density effusion was noted in the sheaths of the second and third compartment extensor tendons. The lipohemarthrosis depicted on imaging classically results from the extrusion of fat from bone marrow into the joint space after an intraarticular fracture. Similarly, a traumatic fat effusion in a tendon sheath presents characteristic imaging features that may help to diagnose a potentially overlooked fracture. (orig.)

  12. Giant cell tumor of the tendon sheath of the hand - magnetic resonance image and orthopaedic treatment

    International Nuclear Information System (INIS)

    Kirova, G.; Monovska, T.; Jablanski, V.; Alexieva, K.; Velev, M.

    2009-01-01

    Giant cell tumour of the tendon sheath (GCT-TS), also known as localized nodular tenosynovitis, is a benign neoplasm that occurs dominantly on the digits. These tumours most commonly occur in patients aged 30-50 years and are associated with degenerative joint disease. GCT-TS usually arises from the synovium of tendon sheets, affecting interfalangeal joints of the hand, feet, ankle and knees. Magnetic Resonance Imaging is able to depict characteristic signal intensities and can accurately assess the tumor size and degree of extent around the phalanx. We present a case of a 36 years-old male patient with GCT-TS in the flexor tendon of his left second finger, diagnosed with Magnetic Resonance imaging. The mass was excised widely with preservation of the flexor tendon without recurrence. (authors)

  13. Long head of the biceps brachii tendon: unenhanced MRI versus direct MR arthrography

    Energy Technology Data Exchange (ETDEWEB)

    Tadros, Anthony S.; Huang, Brady K. [University of California, Department of Radiology, San Diego, CA (United States); Wymore, Lucas; Hoenecke, Heinz; Fronek, Jan [Scripps Clinic, Department of Orthopedic Surgery, La Jolla, CA (United States); Chang, Eric Y. [VA San Diego Healthcare System, Radiology Service, San Diego, CA (United States); University of California, Department of Radiology, San Diego, CA (United States)

    2015-09-15

    We sought to determine the diagnostic accuracy of unenhanced MRI and direct MR arthrography (MRA) for evaluation of the intra-articular long head of the biceps brachii tendon (LHBT) using arthroscopy as the gold standard. A retrospective review of patients who underwent shoulder MRI (n = 132) and MRA (n = 67) within 12 months prior to arthroscopy was performed. MR images were independently reviewed by two blinded musculoskeletal radiologists. Routinely recorded arthroscopic photos/videos were reviewed by an orthopedic surgeon. The LHBT was graded as normal, tendinosis, partial thickness tear less or greater than 50 %, and complete tear. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy for tendinosis and tear detection were calculated. MRI correctly diagnosed fewer normal LHBTs compared to MRA (39-54 % versus 74-84 %, respectively; p < 0.005). MRI and MRA did not differ significantly in the diagnosis of tendinosis (18-36 % and 15-38 %, respectively; p > 0.05) and tears (75-83 % and 64-73 %, respectively; p > 0.05). For tendinosis, MRI versus MRA showed 18-36 % and 15-38 % sensitivity, 69-79 % and 83-91 % specificity, 22-28 % and 18-50 % PPV, 74-76 % and 80-86 % NPV, and 61-64 % and 70-81 % accuracy; respectively. For tears, MRI versus MRA showed 75-83 % and 64-73 % sensitivity, 73-75 % and 82-91 % specificity, 66-69 % and 41-62 % PPV, 82-87 % and 92-94 % NPV, and 74-78 % and 79-88 % accuracy; respectively. No significant difference was found between unenhanced MRI and direct MRA for the detection of tendinosis and tears of LHBTs. (orig.)

  14. Long head of the biceps brachii tendon: unenhanced MRI versus direct MR arthrography

    International Nuclear Information System (INIS)

    Tadros, Anthony S.; Huang, Brady K.; Wymore, Lucas; Hoenecke, Heinz; Fronek, Jan; Chang, Eric Y.

    2015-01-01

    We sought to determine the diagnostic accuracy of unenhanced MRI and direct MR arthrography (MRA) for evaluation of the intra-articular long head of the biceps brachii tendon (LHBT) using arthroscopy as the gold standard. A retrospective review of patients who underwent shoulder MRI (n = 132) and MRA (n = 67) within 12 months prior to arthroscopy was performed. MR images were independently reviewed by two blinded musculoskeletal radiologists. Routinely recorded arthroscopic photos/videos were reviewed by an orthopedic surgeon. The LHBT was graded as normal, tendinosis, partial thickness tear less or greater than 50 %, and complete tear. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy for tendinosis and tear detection were calculated. MRI correctly diagnosed fewer normal LHBTs compared to MRA (39-54 % versus 74-84 %, respectively; p < 0.005). MRI and MRA did not differ significantly in the diagnosis of tendinosis (18-36 % and 15-38 %, respectively; p > 0.05) and tears (75-83 % and 64-73 %, respectively; p > 0.05). For tendinosis, MRI versus MRA showed 18-36 % and 15-38 % sensitivity, 69-79 % and 83-91 % specificity, 22-28 % and 18-50 % PPV, 74-76 % and 80-86 % NPV, and 61-64 % and 70-81 % accuracy; respectively. For tears, MRI versus MRA showed 75-83 % and 64-73 % sensitivity, 73-75 % and 82-91 % specificity, 66-69 % and 41-62 % PPV, 82-87 % and 92-94 % NPV, and 74-78 % and 79-88 % accuracy; respectively. No significant difference was found between unenhanced MRI and direct MRA for the detection of tendinosis and tears of LHBTs. (orig.)

  15. An unusual case of cycticercosis of the tendon sheath of the tendoachilles.

    Directory of Open Access Journals (Sweden)

    Sharat Agarwal

    2010-04-01

    Full Text Available Cysticercosis is an infection by the larval stage (cystcercus cellulosae of the cestode, Taenia Solium (pork tape worm, especially in those individuals who live in the endemic areas. After gaining entry into the body, the larvae become encysted and may lie in subcutaneous tissue, striated muscle, the vitreous humor, or other tissues. We report an unusual case of cysticercosis of the the tendon sheath of the tendoachilles that presented as a swelling of the tendoachilles. Upon Fine Needle Aspiration and Cytology (FNAC that were conducted preoperatively, the possibility of villonodular synovitis was identified. However, the cysticercosis diagnosis was confirmed later after an excisional biopsy was performed. We could find no reports in the literature concerning an occurrence of cysticercosis in the tendon sheath of tendoachilles.

  16. Giant cell tumour of tendon sheath and synovial membrane: A review of 26 cases.

    Science.gov (United States)

    Kant, Kumar Shashi; Manav, Ajoy Kumar; Kumar, Rakesh; Abhinav; Sinha, Vishvendra Kumar; Sharma, Akshat

    2017-11-01

    Aim of our study is to highlight the incidence and benign nature of Giant cell tumour of tendon sheath and need for complete removal, thus minimizing the chances of recurrence. A total of 26 cases of Giant cell tumour of tendon sheath operated in the department of Orthopaedics, Patna Medical College & Hospital, Patna from 2003 to 2010 were included in this study. The surgery was performed after clinical evaluation of the lesion and Fine Needle Aspiration Cytology (FNAC). The tumour underwent en bloc marginal excision. The patients were followed up for minimum two year. Our study population consisted of 18 females and 8 males. The mean age at the time of surgery was 38.3 years (range, 18-62 years). Twenty three cases were found in the 3rd and 4th decade. Twenty two cases involved upper extremity and only 4 cases in lower extremity. MRI was done in 2 cases where diagnosis was in doubt. Bony indentation on X-ray film was found in 7 cases and thorough curettage of cortical shell was done. All the cases were treated by marginal excision. Three cases developed post-operative stiffness but regained full range of movement with physiotherapy. Sensory impairment was seen in 3 cases. Recurrence occurred in 2 case and they were treated by repeat marginal excision. Meticulous en-masse marginal excision of the giant cell tumour of tendon sheath in blood less field using magnification is the treatment of choice.

  17. Physical examination tests and imaging studies based on arthroscopic assessment of the long head of biceps tendon are invalid.

    Science.gov (United States)

    Jordan, Robert W; Saithna, Adnan

    2017-10-01

    The aim of this study was to evaluate whether glenohumeral arthroscopy is an appropriate gold standard for the diagnosis of long head of biceps (LHB) tendon pathology. The objectives were to evaluate whether the length of tendon that can be seen at arthroscopy allows visualisation of areas of predilection of pathology and also to determine the rates of missed diagnoses at arthroscopy when compared to an open approach. A systematic review of cadaveric and clinical studies was performed. The search strategy was applied to MEDLINE, PubMed and Google Scholar databases. All relevant articles were included. Critical appraisal of clinical studies was performed using a validated quality assessment scale. Five articles were identified for inclusion in the review. This included both clinical and cadaveric studies. The overall population comprised 18 cadaveric specimens and 575 patients. Out of the five included studies, three reported the length of LHB tendon visualised during arthroscopy and four reported the rate of missed LHB diagnosis. Cadaveric studies showed that the use of a hook probe allowed arthroscopic visualisation of between 34 and 48 % of the overall length of the LHB. In the clinical series, the rate of missed diagnoses at arthroscopy when compared to open exploration ranged between 33 and 49 %. Arthroscopy allows visualisation of only a small part of the extra-articular LHB tendon. This leads to a high rate of missed pathology in the distal part of the tendon. Published figures for sensitivities and specificities of common physical examination and imaging tests for LHB pathology that are based on arthroscopy as the gold standard are therefore invalid. In clinical practice, it is important to note that a "negative" arthroscopic assessment does not exclude a lesion of the LHB tendon as this technique does not allow visualisation of common sites of distal pathology. IV.

  18. Distal biceps brachii tendon repair: a systematic review of patient outcome determination using modified Coleman methodology score criteria.

    Science.gov (United States)

    Nyland, John; Causey, Brandon; Wera, Jeff; Krupp, Ryan; Tate, David; Gupta, Amit

    2017-07-01

    This systematic literature review evaluated the methodological research design quality of studies that evaluated patient outcomes following distal biceps brachii tendon repair and developed evidence-based recommendations for future patient clinical outcomes research. Following the preferred reporting items for systematic reviews and meta-analyses criteria, and using "biceps brachii", "tendon", "repair" and "outcome assessment" search terms, the CINAHL, Academic Search Premier and MEDLINE databases were searched from January 1960-October 2015. The modified Coleman methodology score (MCMS) served as the primary outcome measure. Descriptive statistical analysis was performed for composite and component MCMS and for patient outcome assessment methodology use frequency. A total of 93 studies were evaluated. Overall MCMS was low (57.1 ± 14). Only 12 (12.9 %) had prospective cohort or randomized controlled trial designs. There was a moderate relationship between publication year and MCMS (r = 0.53, P research study methodological scores improved on average since 2008, generally low MCMS scores, retrospective designs, lack of eccentric elbow flexor or supinator strength testing, and poorly described surgical and rehabilitation descriptions remain commonplace. These findings decrease clinical study validity and generalizability. III.

  19. Cadaveric Study of Insertional Anatomy of Distal Biceps Tendon and its Relationship to the Dynamic Proximal Radioulnar Space.

    Science.gov (United States)

    Bhatia, Deepak N; Kandhari, Vikram; DasGupta, Bibhas

    2017-01-01

    To quantify and assess the relationship between the insertional dimensions of the distal biceps tendon (DBT) and radioulnar space (RUS) in 3 rotational positions. We hypothesized that in all positions RUS would be adequate for the DBT and would remain adequate even after an incremental increase (1 to 3 mm) in tendon thickness. Eleven fresh-frozen cadaveric elbows were dissected; DBT dimensions and bicipital tuberosity measurements were performed and insertional footprints were quantified using a distal biceps footprint index. The RUS was measured at 3 levels of the bicipital tuberosity and in 3 positions of forearm rotation. We performed statistical analysis to analyze differences in RUS (positional and inter-level). In addition, significant differences between DBT thickness (native and incremental) and RUS were analyzed to identify potential sites of radioulnar impingement. The DBT had a mean length of 92 mm; thickness ranged from 2.9 to 6.1 mm. Three variations in DBT insertional footprint were observed and quantified. The RUS linear distance reduced significantly from a supinated to a pronated position at each of 3 bicipital tuberosity levels; the reduction was statistically significant at the lower tuberosity level (45%). Pronation RUS distance was adequate for native DBT thickness and was significantly less when DBT thickness increased by 2 and 3 mm. Radioulnar space reduces significantly from the supinated to the pronated position and is most evident in the lower aspect of the tuberosity. In addition, the RUS in pronation is inadequate for incremental increases in DBT thickness. Postoperative DBT impingement in the RUS may be prevented by avoiding techniques that increase the thickness of the tendon and by using a reattachment site at the proximal aspect of the tuberosity. Copyright © 2017 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  20. The incidence of pathologic changes of the long head of the biceps tendon.

    Science.gov (United States)

    Murthi, A M; Vosburgh, C L; Neviaser, T J

    2000-01-01

    The incidence of primary and secondary bicipital tendinitis remains unknown. In our prospective study, 200 consecutive shoulders underwent arthroscopic subacromial decompression for impingement syndrome. A biceps tenodesis was performed in 80 shoulders (40%) featuring macroscopic degeneration of the long head of the biceps; rotator cuff tears were apparent in 91% of these shoulders, the mean patient age being 55 years. In each of 120 shoulders (60%), an extraarticular tenosynovectomy was performed, and histopathologic studies revealed chronic inflammation in 63% and fibrotic degeneration in 13% of the specimens; rotator cuff tears were evident in 70% (23% full thickness) of these cases, the mean patient age being 47 years. In addition, when glenohumeral arthritis was present, it was uniformly associated with pathologic biceps tenosynovium. In summary, the high incidence of chronic inflammation of the long head of the biceps in shoulders with benign-appearing intraarticular portions viewed arthroscopically is significant, and long head of the biceps disease should also be considered in patients with painful rotator cuff disease and arthritic shoulder conditions.

  1. Systematics of injuries of the rotator cuff and biceps tendon; Systematik der Verletzungen von Rotatorenmanschette und Bizepssehne

    Energy Technology Data Exchange (ETDEWEB)

    Breitenseher, M.J. [Landesklinikum Horn, Institut fuer Radiologie und interventionelle Radiologie, Horn (Austria); Pones, M.; Breitenseher, J.B. [Medizinische Universitaet Wien, Univ.-Klinik fuer Radiodiagnostik, Wien (Austria)

    2015-03-01

    Injuries of the rotator cuff and the biceps tendon demonstrate different patterns, which can be recognized clinically and radiologically. These patterns are impingement syndrome with additional trauma, isolated trauma of the rotator cuff and shoulder dislocation causing rotator cuff tears. Furthermore, it is clinically crucial to evaluate the extent of a rotator cuff injury. Magnetic resonance imaging (MRI) is the modality of choice to differentiate these patterns. (orig.) [German] Bei der Verletzung von Rotatorenmanschette und Bizepssehne koennen verschiedene Muster klinisch und radiologisch erkannt werden. Diese Muster sind das Impingementsyndrom mit einem zusaetzlichen Trauma, das isolierte Trauma und die Verletzung der Rotatorenmanschette im Rahmen einer Schulterluxation. Darueber hinaus ist die Beurteilung des Ausmasses einer Verletzung von zentraler klinischer Relevanz. Die MRT kann die Differenzierung dieser Muster bestmoeglich durchfuehren. (orig.)

  2. Abnormal origins of the long head of the biceps tendon can lead to rotator cuff pathology: a report of two cases.

    Science.gov (United States)

    Zhang, Alan L; Gates, Cameron H; Link, Thomas M; Ma, C Benjamin

    2014-11-01

    Previous case reports have highlighted various anomalous origins of the long head of the biceps tendon (LHBT) that do not originate from the superior glenoid labrum or supraglenoid tubercle. Yet, these cases were all reported as incidental findings and were not thought to cause any significant shoulder pathology. We present the magnetic resonance (MR) imaging and clinical treatment of two cases where aberrant intra-articular origins of the long head of the biceps tendon from the anterior edge of the supraspinatus tendon may have contributed to symptomatic rotator cuff pathology. Arthroscopy confirmed MR findings of partial articular-sided supraspinatus lesions in close proximity to the anomalous origins and treatment with tenodesis of the LHBT successfully relieved symptoms. Although rare occurrences with subtle and potentially misleading imaging findings, it is important to be aware of aberrant origins of the LHBT that may contribute to concomitant rotator cuff pathology.

  3. Mapping the articular contact area of the long head of the biceps tendon on the humeral head.

    Science.gov (United States)

    Morris, Brent J; Byram, Ian R; Lathrop, Ray A; Dunn, Warren R; Kuhn, John E

    2014-01-01

    The purpose of this investigation was to calculate the contact surface area of the long head of the biceps (LHB) in neutral position and abduction. We sought to determine whether the LHB articulates with the humeral head in a consistent pattern comparing articular contact area in neutral position and abduction. Eleven fresh frozen matched cadaveric shoulders were analyzed. The path of the biceps tendon on the articular surface of the humeral head and the total articular surface were digitized using a MicronTracker 2 H3-60 three-dimensional optical tracker. Contact surface area was significantly less in abduction than in neutral position (P = 0.002) with a median ratio of 41% (36%, 47.5%). Ratios of contact area in neutral position to full articular surface area were consistent between left and right shoulders (rho = 1, P = 0.017) as were ratios of abduction area to full articular surface area (rho = 0.97, P = 0.005). The articular contact surface area is significantly greater in neutral position than abduction. The ratios of articular contact surface areas to total humeral articular surface areas have a narrow range and are consistent between left and right shoulders of the same cadaver.

  4. Common Peroneal Nerve Palsy with Multiple-Ligament Knee Injury and Distal Avulsion of the Biceps Femoris Tendon

    Directory of Open Access Journals (Sweden)

    Takeshi Oshima

    2015-01-01

    Full Text Available A multiple-ligament knee injury that includes posterolateral corner (PLC disruption often causes palsy of the common peroneal nerve (CPN, which occurs in 44% of cases with PLC injury and biceps femoris tendon rupture or avulsion of the fibular head. Approximately half of these cases do not show functional recovery. This case report aims to present a criteria-based approach to the operation and postoperative management of CPN palsy that resulted from a multiple-ligament knee injury in a 22-year-old man that occurred during judo. We performed a two-staged surgery. The first stage was to repair the injuries to the PLC and biceps femoris. The second stage involved anterior cruciate ligament reconstruction. The outcomes were excellent, with a stable knee, excellent range of motion, and improvement in the palsy. The patient was able to return to judo competition 27 weeks after the injury. To the best of our knowledge, this is the first case report describing a return to sports following CPN palsy with multiple-ligament knee injury.

  5. Mapping the Articular Contact Area of the Long Head of the Biceps Tendon on the Humeral Head

    Directory of Open Access Journals (Sweden)

    Brent J. Morris

    2014-01-01

    Full Text Available The purpose of this investigation was to calculate the contact surface area of the long head of the biceps (LHB in neutral position and abduction. We sought to determine whether the LHB articulates with the humeral head in a consistent pattern comparing articular contact area in neutral position and abduction. Eleven fresh frozen matched cadaveric shoulders were analyzed. The path of the biceps tendon on the articular surface of the humeral head and the total articular surface were digitized using a MicronTracker 2 H3-60 three-dimensional optical tracker. Contact surface area was significantly less in abduction than in neutral position (P=0.002 with a median ratio of 41% (36%, 47.5%. Ratios of contact area in neutral position to full articular surface area were consistent between left and right shoulders (rho=1, P=0.017 as were ratios of abduction area to full articular surface area (rho= 0.97, P=0.005. The articular contact surface area is significantly greater in neutral position than abduction. The ratios of articular contact surface areas to total humeral articular surface areas have a narrow range and are consistent between left and right shoulders of the same cadaver.

  6. MR imaging findings in flexed abducted supinated (FABS) position and clinical presentation following refixation of distal biceps tendon rupture using bioabsorbable suture anchors

    International Nuclear Information System (INIS)

    Marnitz, T.; Steffen, I.G.; Denecke, T.; Elgeti, F.A.; Spiegel, D.; Hug, K.; Hueper, M.; Gerhardt, C; Greiner, S.; Scheibel, M.

    2012-01-01

    Purpose: To correlate MRI findings after suture anchor repair of distal biceps tendons with symptoms. Materials and Methods: 24 men with 25 distal biceps tendon ruptures (one bilateral) treated with suture anchor repair were retrospectively included. Follow-up after a mean of 31 months (range, 12 - 74) included clinical examination and MRI. The pain level and flexion strength compared to the uninvolved arm were recorded. MRI was performed at 1.5 T obtaining FABS position images (both elbows in 7 patients) and evaluated for artifacts, signal abnormalities, and rerupture by two experienced readers in consensus and blinded to symptoms. Pain and loss of flexion strength > 20 % were tested against MRI findings as dichotomous data using Fisher's exact chi-square tests (p 0.05). There was a 2.7-fold mean increase of the tendon cross-sectional area on the repaired side compared to the uninvolved contralateral tendon (p = 0.02). Conclusion: We found good MRI visualization of postoperative tendons, but no correlation between symptoms and MRI signal abnormalities or rerupture. The increase in caliber of the repaired tendon might promote an impingement in pronation. (orig.)

  7. Repair of distal biceps brachii tendon assessed with 3-T magnetic resonance imaging and correlation with functional outcome

    Energy Technology Data Exchange (ETDEWEB)

    Alemann, Guillaume; Dietsch, Emmanuel [University Hospital of Besancon, Department of Musculoskeletal Imaging, Besancon (France); Gallinet, David; Obert, Laurent [University Hospital of Besancon, Department of Orthopedic Surgery, Besancon (France); Kastler, Bruno; Aubry, Sebastien [University Hospital of Besancon, Department of Musculoskeletal Imaging, Besancon (France); Franche Comte University, I4S Laboratory-EA 4268-IFR 133, Besancon (France)

    2015-05-01

    Objectives were to study the MRI appearance of the repaired distal biceps tendon (DBT), anatomically reinserted, and to search for a correlation between tendon measurements and functional results. Twenty-five patients (mean age, 49 ± 4.9 years old) who benefited from 3-T MRI follow-up of the elbow after surgical reinsertion of the DBT were retrospectively included and compared to a control group (n = 25; mean age, 48 ± 10 years old). MRI was performed during the month of clinical follow-up and on average 22 months after surgery. Delayed complications (secondary avulsion, new rupture), intratendinous osteoma, tendinous signal on T1-weighted (T1{sub w}) and fat-suppressed proton density-weighted (FS-PD{sub w}) images as well as DBT measurements were recorded. The maximum isometric elbow flexion strength (MEFS) and range of motion of the elbow were assessed. Repaired DBT demonstrated a heterogeneous but normally fibrillar structure. Its low T1{sub w} signal was less pronounced than that of normal tendons, and the FS-PD{sub W} image signal was similar to that of T1{sub w} images. MRI detected seven osteomas (Se = 53 % vs. plain radiography), one textiloma and one secondary avulsion. Repaired DBT measurements were significantly correlated with MEFS (dominant arm R2: 0.38; nondominant arm R2: 0.54); this correlation involved the insertion surface (Δ = -75.7 mm{sup 2}, p = 0.046), transverse diameter (Δ = -2.6 mm, p = 0.018), anteroposterior diameter at the level of the radial head (Δ = -3.9 mm, p = 0.001) and DBT cross-sectional area (Δ = -50.2 mm{sup 2}, p = 0.003). The quality of functional outcome after anatomical elbow rehabilitation of DBT correlates with the extent of tendinous hypertrophy during the healing process. (orig.)

  8. Repair of distal biceps brachii tendon assessed with 3-T magnetic resonance imaging and correlation with functional outcome

    International Nuclear Information System (INIS)

    Alemann, Guillaume; Dietsch, Emmanuel; Gallinet, David; Obert, Laurent; Kastler, Bruno; Aubry, Sebastien

    2015-01-01

    Objectives were to study the MRI appearance of the repaired distal biceps tendon (DBT), anatomically reinserted, and to search for a correlation between tendon measurements and functional results. Twenty-five patients (mean age, 49 ± 4.9 years old) who benefited from 3-T MRI follow-up of the elbow after surgical reinsertion of the DBT were retrospectively included and compared to a control group (n = 25; mean age, 48 ± 10 years old). MRI was performed during the month of clinical follow-up and on average 22 months after surgery. Delayed complications (secondary avulsion, new rupture), intratendinous osteoma, tendinous signal on T1-weighted (T1 w ) and fat-suppressed proton density-weighted (FS-PD w ) images as well as DBT measurements were recorded. The maximum isometric elbow flexion strength (MEFS) and range of motion of the elbow were assessed. Repaired DBT demonstrated a heterogeneous but normally fibrillar structure. Its low T1 w signal was less pronounced than that of normal tendons, and the FS-PD W image signal was similar to that of T1 w images. MRI detected seven osteomas (Se = 53 % vs. plain radiography), one textiloma and one secondary avulsion. Repaired DBT measurements were significantly correlated with MEFS (dominant arm R2: 0.38; nondominant arm R2: 0.54); this correlation involved the insertion surface (Δ = -75.7 mm 2 , p = 0.046), transverse diameter (Δ = -2.6 mm, p = 0.018), anteroposterior diameter at the level of the radial head (Δ = -3.9 mm, p = 0.001) and DBT cross-sectional area (Δ = -50.2 mm 2 , p = 0.003). The quality of functional outcome after anatomical elbow rehabilitation of DBT correlates with the extent of tendinous hypertrophy during the healing process. (orig.)

  9. Diagnostic accuracy of 3T conventional shoulder MRI in the detection of the long head of the biceps tendon tears associated with rotator cuff tendon tears

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ro Woon; Choi, Soo-Jung; Ahn, Jae Hong; Shin, Dong Rock; Kang, Chae Hoon [University of Ulsan, College of Medicine, Department of Radiology, Asan Foundation, Gangneung Asan Hospital, Gangneung-si, Gangwon-do (Korea, Republic of); Lee, Man Ho [Andong Medical Center, Department of Radiology, Andong-si, Gyeongsangbuk-do (Korea, Republic of); Lee, Ki Won [University of Ulsan, College of Medicine, Department of Orthopedic Surgery, Asan Foundation, Gangneung Asan Hospital, Gangneung-si, Gangwon-do (Korea, Republic of)

    2016-12-15

    To evaluate the diagnostic performance (DP) of 3T (3 Tesla field strength) conventional shoulder magnetic resonance imaging (MRI) in detecting the long head of the biceps tendon (LHBT) tears in association with rotator cuff tendon tears. This study included 80 consecutive patients who underwent arthroscopic surgery for rotator cuff tendon tears. Two radiologists independently evaluated the preoperative 3T shoulder MRI for the presence of LHBT tears. The DP of MRI was evaluated using the results of arthroscopy as the reference standard. We also evaluated the DP of several MR signs of LHBT in detection of partial LHBT tears. Arthroscopic examination revealed 35 partial and 5 complete tears. According to the results of evaluation by reviewers 1 and 2, shoulder MRI exhibited sensitivities of 77.14 and 80 % and specificities of 71.11 and 73.33 % in detection of partial LHBT tears and sensitivities of 80 and 100 % and a specificity of 100% (both) in detection of complete LHBT tears. In detecting partial LHBT tears, increased T2 signal intensity of the LHBT exhibited high sensitivities (reviewers 1 and 2; 82.85 and 80 %, respectively) and the presence of intratendinous defects or C-signs exhibited the highest specificities (reviewers 1 and 2; 95.55 and 93.33 %, respectively), followed by abnormalities in shape and outer margins of the LHBT (reviewers 1 and 2; 91.11 and 82 %; 91.11 and 86.66 %, respectively). Non-contrast-enhanced 3T shoulder MRI is potentially highly accurate in detection of complete LHBT tears, but moderately accurate in detection of partial LHBT tears. (orig.)

  10. Diagnostic accuracy of 3T conventional shoulder MRI in the detection of the long head of the biceps tendon tears associated with rotator cuff tendon tears

    International Nuclear Information System (INIS)

    Lee, Ro Woon; Choi, Soo-Jung; Ahn, Jae Hong; Shin, Dong Rock; Kang, Chae Hoon; Lee, Man Ho; Lee, Ki Won

    2016-01-01

    To evaluate the diagnostic performance (DP) of 3T (3 Tesla field strength) conventional shoulder magnetic resonance imaging (MRI) in detecting the long head of the biceps tendon (LHBT) tears in association with rotator cuff tendon tears. This study included 80 consecutive patients who underwent arthroscopic surgery for rotator cuff tendon tears. Two radiologists independently evaluated the preoperative 3T shoulder MRI for the presence of LHBT tears. The DP of MRI was evaluated using the results of arthroscopy as the reference standard. We also evaluated the DP of several MR signs of LHBT in detection of partial LHBT tears. Arthroscopic examination revealed 35 partial and 5 complete tears. According to the results of evaluation by reviewers 1 and 2, shoulder MRI exhibited sensitivities of 77.14 and 80 % and specificities of 71.11 and 73.33 % in detection of partial LHBT tears and sensitivities of 80 and 100 % and a specificity of 100% (both) in detection of complete LHBT tears. In detecting partial LHBT tears, increased T2 signal intensity of the LHBT exhibited high sensitivities (reviewers 1 and 2; 82.85 and 80 %, respectively) and the presence of intratendinous defects or C-signs exhibited the highest specificities (reviewers 1 and 2; 95.55 and 93.33 %, respectively), followed by abnormalities in shape and outer margins of the LHBT (reviewers 1 and 2; 91.11 and 82 %; 91.11 and 86.66 %, respectively). Non-contrast-enhanced 3T shoulder MRI is potentially highly accurate in detection of complete LHBT tears, but moderately accurate in detection of partial LHBT tears. (orig.)

  11. Visualization of the extra-articular portion of the long head of the biceps tendon during intra-articular shoulder arthroscopy.

    Science.gov (United States)

    Festa, Anthony; Allert, Jesse; Issa, Kimona; Tasto, James P; Myer, Jonathan J

    2014-11-01

    To quantify the amount of the extra-articular long head of the biceps tendon (LHBT) seen during intra-articular shoulder arthroscopy by pulling the tendon into the joint with a probe through an anterior portal while viewing through a standard posterior portal. Intra-articular shoulder arthroscopy was performed on 10 forequarter cadaveric specimens. The extra-articular portion of the LHBT was evaluated by pulling the tendon into the joint with an arthroscopic probe inserted through an anterior portal. The tendon was marked at the pulley insertion on the humerus with a vascular clip before and after the tendon was pulled into the joint. An open deltopectoral approach was performed, and the amount of extra-articular tendon visualized was calculated as an absolute amount and in relation to nearby anatomic structures. An additional 1.9 cm (range, 1.4 to 2.6 cm) of extra-articular LHBT was viewed by pulling the tendon into the joint with an arthroscopic probe through an anterior portal during shoulder arthroscopy. This represented 30.8% of the extra-articular portion of the tendon, 47.7% of tendon in the bicipital groove, and 76.3% of the tendon that lies under the area from the pulley insertion to the distal edge of the transverse humeral ligament. During intra-articular shoulder arthroscopy, the extra-articular portion of the LHBT is incompletely visualized by pulling the tendon into the joint with a probe placed through an anterior portal while viewing through a standard posterior portal. An additional extra-articular portion of the LHBT may be viewed by pulling the tendon into the joint with an arthroscopic probe during shoulder arthroscopy. Copyright © 2014 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  12. Evaluation of the clinical-functional results from repairing extensive rotator cuff injury with inclusion of the tendon of the long head of the biceps

    Directory of Open Access Journals (Sweden)

    Roberto Yukio Ikemoto

    2013-04-01

    Full Text Available OBJECTIVES: To assess the outcomes of the arthroscopic margin convergence of the posterior cuff to the biceps tendon. METHODS: From October 2003 to December 2007, 20 patients with massive rotator cuff tear which include the rotator interval were treated with arthroscopic margin convergence of the posterior cuff to biceps tendon. Sixteen patients were female and four were male. The mean age was 58.95 years old. The dominant side was affected in 16 cases (80%. The outcomes were analysed according to the UCLA Score with a minimum follow-up period of two years. RESULTS: The UCLA score improved, on average, 14 points (p < 0.001. Six patients had excellent results; nine good; three fair and two poor results. The mean improvement of forward flexion was 33º (p < 0.001, 3º of external rotation (p < 0.396 and two vertebral levels for internal rotation (p < 0.025. CONCLUSION: The arthroscopic margin convergence of the posterior cuff to the biceps tendon leads to satisfactory results.

  13. Giant cell tumors of the tendon sheath may present radiologically as intrinsic osseous lesions

    Energy Technology Data Exchange (ETDEWEB)

    Schepper, A.M. de; Bloem, J.L. [Leiden University Medical Center, Department of Radiology, Albinusdreef 2, P.O. Box 9600, RC Leiden (Netherlands); Hogendoorn, P.C.W. [Leiden University Medical Center, Department of Pathology, Albinusdreef 2, P.O. Box 9600, RC Leiden (Netherlands)

    2007-02-15

    The purpose of this study was to explain radiographic features of giant cell tumors of the tendon sheath (GCTTS), in particular, osseous extension, by correlating imaging findings with histology in order to increase the accuracy of radiological diagnosis. In a series of 200 consecutive osseous (pseudo) tumors of the hand, on radiography, six patients presented with an intrinsic osseous lesion caused by a histologically confirmed neighboring GCTTS. Available radiographs, computed tomography (CT), and contrast-enhanced magnetic resonance (MR) images were correlated with histology. Radiography showed osseous lesions consisting of well-defined cortical defects in four (one of whom also demonstrated cortical scalloping) and a slightly expansile, well-defined osteolytic lesion in two patients. MR obtained in four patients showed the extraosseous tumor invading/eroding bone and causing cortical scalloping (three and one patients, respectively). Extension depicted on MR was confirmed on the two available resection specimens. All lesions were polylobular (cauliflower or mushroom like) and neighbored tendon sheaths. Dense collagen and hemosiderin-loaded macrophages explained the high CT attenuation and the low MR signal intensity on T2-weighted images that was observed in all four MR and in all two CT scans. The high density of proliferative capillaries explained the marked enhancement observed in all four patients with gadolinium (Gd)-chelate-enhanced MR imaging. GCTTS is a soft tissue (pseudo) tumor that may invade bone and as a consequence mimick an intrinsic osseous lesion on radiographs. In such cases, specific MR and CT features that can be explained by histological findings can be used to suggest the correct diagnosis. (orig.)

  14. Biceps Tendon Lengthening Surgery for Failed Serial Casting Patients With Elbow Flexion Contractures Following Brachial Plexus Birth Injury.

    Science.gov (United States)

    Nath, Rahul K; Somasundaram, Chandra

    2016-01-01

    Assessment of surgical outcomes of biceps tendon lengthening (BTL) surgery in obstetric brachial plexus injury (OBPI) patients with elbow flexion contractures, who had unsuccessful serial casting. Serial casting and splinting have been shown to be effective in correcting elbow flexion contractures in OBPI. However, the possibilities of radial head dislocations and other complications have been reported in serial casting and splinting. Literature indicates surgical intervention when such nonoperative techniques and range-of-motion exercises fail. Here, we demonstrated a significant reduction of the contractures of the affected elbow and improvement in arm length to more normal after BTL in these patients, who had unsuccessful serial casting. Ten OBPI patients (6 girls and 4 boys) with an average age of 11.2 years (4-17.7 years) had BTL surgery after unsuccessful serial casting. Mean elbow flexion contracture was 40° before and 37° (average) after serial casting. Mean elbow flexion contracture was reduced to 8° (0°-20°) post-BTL surgical procedure with an average follow-up of 11 months. This was 75% improvement and statistically significant (P casting. These OBPI patients in our study had 75% significant reduction in elbow flexion contractures and achieved an improved and more normal length of the affected arm after the BTL surgery when compared to only 7% insignificant reduction and no improvement in arm length after serial casting.

  15. Measurement of the tendon of the biceps brachii after tenotomy: study on cadavers

    Directory of Open Access Journals (Sweden)

    Anderson Cunha Machado

    2015-08-01

    Full Text Available ABSTRACTOBJECTIVE: To evaluate the influence of elbow and forearm range of motion on the distal excursion of the long head of the biceps (LHB. METHODS: The distal excursion of the LHB after tenotomy of the shoulders of eight cadavers was ascertained by measuring the distance between a point marked out on the LHB, 3 cm from the anterolateral border of the acromion, and its position at different degrees of elbow flexion, using a digital pachymeter. The measurements at elbow flexion of 135°, 90°, 45° and 0° were noted: these angles were established using a goniometer. The measurements were made with the forearm in neutral, supination and pronation positions. RESULTS: Differences between the mean measurements of the distal excursion of the LHB (total sample were observed between the degrees of elbow flexion ( p< 0.01. However, no statistical differences were observed between the different forearm positions, between the sides, genders and ages of the cadavers studied. CONCLUSION: Progressive extension of the elbow caused progressive distal excursion of the LHB, but without interference in the forearm position, gender, side or age of the cadavers studied.

  16. Biceps tendinitis and subluxation.

    Science.gov (United States)

    Patton, W C; McCluskey, G M

    2001-07-01

    Since the 17th century, the long head of the biceps tendon as a source of shoulder pain and its functional significance has been a source of debate. Although the term tendinitis is commonly used, overuse tendon injuries infrequently demonstrate inflammatory cells; instead, degenerative changes resulting from the failure of self-repair usually are found. Bicipital tendinitis or bicipital tenosynovitis is most often secondary to impingement beneath the coracoacromical arch. Primary bicipital tendinitis and tendinitis secondary to instability are possible, however. Through a careful history, physical examination, and appropriate imaging studies, the clinician can establish the diagnosis of disorders of the biceps tendon Arthroscopic evaluation greatly improves the diagnosis and treatment of biceps tendon and related shoulder pathology. Although the exact functional role of the biceps tendon remains incompletely defined, a growing body of evidence supports its role as a stabilizer of the glenohumeral joint. This stabilizing function should be incorporated into the treatment of biceps tendon disorders. Routine tenodesis has been replaced by a more individualized approach, taking into consideration physiologic age, activity level, expectations, and exact shoulder pathology present. New repair techniques are under development, and preservation of the biceps-labral complex is now preferred when possible.

  17. Long bicipital tendon of the shoulder: normal anatomy and pathologic findings on MR imaging.

    Science.gov (United States)

    Erickson, S J; Fitzgerald, S W; Quinn, S F; Carrera, G F; Black, K P; Lawson, T L

    1992-05-01

    The tendon of the long head of the biceps muscle (long bicipital tendon) has a complex course from its muscle belly to its insertion onto the supraglenoid tubercle/glenoid labrum. It is stabilized by numerous tendinous and ligamentous structures and is, in turn, partly responsible for maintenance of normal glenohumeral function. In this report we describe the anatomy of this tendon, correlating high-resolution MR images with cryomicrotome sections. We illustrate typical MR findings in pathologic conditions affecting the long bicipital tendon sheath, the substance of the tendon, and finally the tendon position.

  18. Rare muscular variations identified in a single cadaveric upper limb: a four-headed biceps brachii and muscular elevator of the latissimus dorsi tendon.

    Science.gov (United States)

    Moore, Colin W; Rice, Charles L

    2018-03-01

    Supernumerary or accessory heads of the biceps brachii are persistent muscular structures which can vary in number and location in the arm. Variations in other arm muscles, such as the coracobrachialis, can accompany supernumerary biceps brachii musculature in the upper limb. In this case report, we describe two rare muscular variants in a single adult male: a four-headed biceps brachii and the muscular elevator of the latissimus dorsi tendon. Additionally, accessory muscles of the brachialis and flexor digiti minimi brevis were identified in the upper limb. To our knowledge, the muscular variants identified here are considered rare, and their co-occurrence in a single upper limb has not been described previously. Also, a four-headed biceps brachii consisting of both the infero-medial and infero-lateral humeral heads has not been described previously to our knowledge. We postulate that the simultaneous appearance of several muscular variations may indicate a signaling disruption in embryogenesis during muscle patterning of the ventral limb bud. Knowledge of variant musculature in the arm is important for surgeons and clinicians as these muscles and their aberrant innervation patterns can complicate surgical procedures and may compress arteries and nerves producing upper limb pain and paresthesia. The clinical, functional and embryological implications of the upper limb variants are discussed.

  19. Achilles Tendonitis

    Science.gov (United States)

    ... almost impossible. Achilles tendonitis is a very common running injury. But it can also affect basketball players, dancers, ... Proximal Biceps Tendonitis Safety Tips: Basketball Safety Tips: Running Repetitive Stress Injuries Sports and Exercise Safety Dealing With Sports Injuries ...

  20. Frontal plane fractures of the accessory carpal bone and implications for the carpal sheath of the digital flexor tendons.

    Science.gov (United States)

    Minshall, G J; Wright, I M

    2014-09-01

    Accurate radiological and ultrasonographic descriptions of frontal plane fractures of the accessory carpal bone (ACB) are lacking, and implications of these fractures for the carpal sheath and its contents have not previously been reported. Aims were as follows: 1) to describe the location and radiological features of frontal plane fractures of the ACB; 2) to document communication of displaced fractures with the carpal sheath and consequent injury to the deep digital flexor tendon (DDFT); 3) to describe ultrasonographic identification of lesions; and 4) to report tenoscopic evaluation and treatment. Retrospective case series. Analysis of frontal plane fractures of the ACB referred to a single hospital between 2006 and 2012, including review of radiographic, ultrasonographic and tenoscopic images. Nine fractures were identified, of which 8 displaced fractures all communicated with the carpal sheath. Comminuted fragments and/or protruding fracture margins lacerated the lateral margin of the enclosed DDFT. This was identifiable ultrasonographically and confirmed at tenoscopy in 7 cases. Treatment in these horses consisted of removal of torn tendon tissue together with fragmentation and protuberant fracture edges, and 7 of 7 cases returned to work. One horse with a nondisplaced fracture was managed with immobilisation; the fracture healed, and the horse returned to work. One horse with a displaced fracture was retired to stud. Frontal plane fractures of the ACB occur palmar to the groove in its lateral margin for the tendon of insertion of ulnaris lateralis. Comminuted fragments can displace distally within the carpal sheath to a mid-metacarpal level or abaxially to lie extrathecally, lateral to the parent bone. Displaced fractures communicate with the carpal sheath and traumatise the DDFT. © 2013 EVJ Ltd.

  1. Direct lentiviral-cyclooxygenase 2 application to the tendon-bone interface promotes osteointegration and enhances return of the pull-out tensile strength of the tendon graft in a rat model of biceps tenodesis.

    Directory of Open Access Journals (Sweden)

    Charles H Rundle

    Full Text Available This study sought to determine if direct application of the lentiviral (LV-cyclooxygenase 2 (COX2 vector to the tendon-bone interface would promote osteointegration of the tendon graft in a rat model of biceps tenodesis. The LV-COX2 gene transfer strategy was chosen for investigation because a similar COX2 gene transfer strategy promoted bony bridging of the fracture gap during bone repair, which involves similar histologic transitions that occur in osteointegration. Briefly, a 1.14-mm diameter tunnel was drilled in the mid-groove of the humerus of adult Fischer 344 rats. The LV-COX2 or βgal control vector was applied directly into the bone tunnel and onto the end of the tendon graft, which was then pulled into the bone tunnel. A poly-L-lactide pin was press-fitted into the tunnel as interference fixation. Animals were sacrificed at 3, 5, or 8 weeks for histology analysis of osteointegration. The LV-COX2 gene transfer strategy enhanced neo-chondrogenesis at the tendon-bone interface but with only marginal effect on de novo bone formation. The tendon-bone interface of the LV-COX2-treated tenodesis showed the well-defined tendon-to-fibrocartilage-to-bone histologic transitions that are indicative of osteointegration of the tendon graft. The LV-COX2 in vivo gene transfer strategy also significantly enhanced angiogenesis at the tendon-bone interface. To determine if the increased osteointegration was translated into an improved pull-out mechanical strength property, the pull-out tensile strength of the LV-COX2-treated tendon grafts was determined with a pull-out mechanical testing assay. The LV-COX2 strategy yielded a significant improvement in the return of the pull-out strength of the tendon graft after 8 weeks. In conclusion, the COX2-based in vivo gene transfer strategy enhanced angiogenesis, osteointegration and improved return of the pull-out strength of the tendon graft. Thus, this strategy has great potential to be developed into an

  2. Proximal Biceps Tendonitis

    Science.gov (United States)

    ... you to have an X-ray , ultrasound, or magnetic resonance imaging (MRI) scan . How Can I Prevent ... to avoid using your injured arm for any lifting or reaching. Ice the affected area. Apply ice ...

  3. Instability of the long head of the biceps tendon in patients with rotator cuff tear: evaluation on magnetic resonance arthrography of the shoulder with arthroscopic correlation

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Yusuhn; Lee, Joon Woo; Ahn, Joong Mo; Lee, Eugene; Kang, Heung Sik [Seoul National University Bundang Hospital, Department of Radiology, Seongnam-si, Gyeonggi-do (Korea, Republic of)

    2017-10-15

    To evaluate the diagnostic value of MR arthrography (MRA) in diagnosing instability of the LHBT in patients with rotator cuff tendon tear. The MR arthrograms of 101 patients were retrospectively reviewed and correlated with arthroscopic findings as the standard reference. Images were evaluated for (1) the integrity of the LHBT, (2) the position of the LHBT (subluxation/dislocation on axial images, inferior displacement on oblique sagittal image) and (3) the integrity of the biceps pulley (SGHL, supraspinatus and subscapularis tendon adjacent to the rotator interval). The integrity of the LHBT was correctly classified in 74.3% (75/101) and 66.3% (67/101) by readers 1 and 2, respectively. The diagnosis of LHBT instability could be made on axial images with a sensitivity of 82.6% and 73.9% and specificity of 69.9% and 87.7%, whereas the displacement sign on sagittal images had a sensitivity of 73.9% and 78.3% and a specificity of 64.4% and 61.6%, respectively. Assessing the integrity of the SGHL had a sensitivity of 60.9 and 93.3% and a specificity of 70.4 and 75.0%, respectively. By combining the different image findings, the accuracy in assessing LHBT instability was 80.9 and 90.5% with a sensitivity of 60.9 and 86.7% and specificity of 83.1 and 91.8%, respectively. Individual image findings may have a limited role in diagnosing LHBT instability in patients with rotator cuff tendon tear. The accuracy of MRA may be improved by assessing the integrity of the biceps pulley structures along with the position of the LHBT on both axial and sagittal images. (orig.)

  4. Intra-articular fibroma of tendon sheath in a knee joint associated with iliotibial band friction syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Ha, Dong Ho; Choi, Sun Seob; Kim, Soo Jin; Lih, Wang [Dong-A University Medical Center, Busan (Korea, Republic of)

    2015-02-15

    Iliotibial band (ITB) friction syndrome is a common overuse injury typically seen in the active athlete population. A nodular lesion on the inner side of the ITB as an etiology or an accompanying lesion from friction syndrome has been rarely reported. A 45-year-old male presented with recurrent pain and a movable nodule at the lateral joint area, diagnosed as ITB friction syndrome. The nodule was confirmed as a rare intra-articular fibroma of the tendon sheath (FTS) on the basis of histopathologic findings. We describe the MRI findings, arthroscopic and pathologic features, in this case of intra-articular FTS presenting with ITB friction syndrome.

  5. Intra-articular fibroma of tendon sheath in a knee joint associated with iliotibial band friction syndrome

    International Nuclear Information System (INIS)

    Ha, Dong Ho; Choi, Sun Seob; Kim, Soo Jin; Lih, Wang

    2015-01-01

    Iliotibial band (ITB) friction syndrome is a common overuse injury typically seen in the active athlete population. A nodular lesion on the inner side of the ITB as an etiology or an accompanying lesion from friction syndrome has been rarely reported. A 45-year-old male presented with recurrent pain and a movable nodule at the lateral joint area, diagnosed as ITB friction syndrome. The nodule was confirmed as a rare intra-articular fibroma of the tendon sheath (FTS) on the basis of histopathologic findings. We describe the MRI findings, arthroscopic and pathologic features, in this case of intra-articular FTS presenting with ITB friction syndrome.

  6. Calcific tendinitis of the long head of the biceps brachii distal to the glenohumeral joint: plain film radiographic findings.

    Science.gov (United States)

    Goldman, A B

    1989-11-01

    Calcific tendinitis is a painful condition related to deposition of hydroxyapatite crystals; it favors large joints. The shoulder, specifically the tendons of the rotator cuff and the insertion of the long head of the biceps on the superior glenoid rim, is a well-recognized location for this abnormality. The purpose of this article is to describe a second site of calcific tendinitis of the biceps, distal to the joint and corresponding to the junction of the tendon and muscle. Radiographs in 119 cases of calcific tendinitis of the shoulder, obtained between 1980 and 1988, were reviewed. Twenty had calcific tendinitis in the region of the tendon of the long head of the biceps (nine at the glenoid insertion and 11 adjacent to the humeral shaft). All 11 patients with calcific tendinitis at the more distal site had a small, homogeneous deposit adjacent to the proximal humeral shaft. The densities in these 11 cases followed the normal course of the tendon of the long head of the biceps and were therefore medial to the proximal humeral shaft on the internal rotation view, lateral to the proximal humeral shaft on the external rotation view, and anterior to the proximal humeral shaft on the axillary projection. The major differential diagnosis of calcific tendinitis of the tendon of the long head of the biceps is loose bodies trapped in the biceps tendon sheath. Although the position of the soft-tissue densities in these two entities is similar, loose bodies have an appearance of bone, and their source (degenerative arthritis or recurrent dislocations) is usually apparent. A site of calcific tendinitis distal to the glenohumeral joint that is detectable on plain films is reviewed. Accurate diagnosis depends on understanding the anatomy of the tendon of the long head of the biceps brachii. The clinical charts of the 11 patients also are summarized, with emphasis on the association between the roentgen finding and bicipital tendinitis and impingement syndrome.

  7. ARTHROSCOPIC CORRECTION OF THE INJURIES OF THE COMPLEX «TENDON OF THE BICEPS LONG HEAD - THE ARTICULAR LIP» IN TREATMENT OF PATIENTS WITH FULL-LAYER RUPTURES OF THE ROTATOR CUFF

    Directory of Open Access Journals (Sweden)

    S. Y. Dokolin

    2013-01-01

    Full Text Available Damage of the long head of the biceps at the place of attachment to the articular tubercle supraglenoidal lip of shoulder, to the entrance and throughout intertubercle furrows are common causes of pain and dysfunction of the shoulder joint. At the same clinical manifestations of the morphology of such lesions may be different. The current literature discusses various options of surgical correction of the biceps injury. Variety of methods of surgical treatment and the lack of consensus in support of their application in different patients in different types of injuries were the basis for the present study. A prospective analysis of the functional results of surgical treatment of the 34 - year’s patients with associated rotator cuff (SSP+ISP+SSC+ and the tendon of the biceps muscle in age from 34 to 75 years. Options for surgical correction of the damaged part of the biceps were: biceps tenotomy, biceps tenotomy with intraarticular tenodez of the shoulder to the head before entering intertubercle furrow, biceps tenotomy and extraarticular subpectorialtenodez to the proximal humerus is intertubercle interferrent screw groove, as well as its attachment to the tendon suture large pectoral muscle. Choice of surgical approach depended on the patient's age, level of daily physical activity, morphology and localization of lesions. The best results were obtained when the extra-articular subpectorialtenodez of long head of the biceps to the proximal humerus interferrent screw and suture fixation to the pectoralis major muscle, the average follow-up was 16,6 ± 4,7 months.

  8. Arthroscopic Release of Flexor Hallucis Longus Tendon Sheath in Female Ballet Dancers: Dynamic Pathology, Surgical Technique, and Return to Dancing Performance.

    Science.gov (United States)

    Funasaki, Hiroki; Hayashi, Hiroteru; Sakamoto, Kanako; Tsuruga, Rei; Marumo, Keishi

    2015-12-01

    Stenosing tenosynovitis of the flexor hallucis longus (FHL) tendon is known as a major overuse lesion in female dancers. We describe arthroscopic surgical techniques in relation to the dynamic pathology of the disease. Crepitus and pain on moving the great toe with the ankle in plantar flexion on preoperative examination confirm the diagnosis of FHL stenosing tenosynovitis even if the os trigonum is not evident. The ankle is approached through standard posterolateral and posteromedial portals. A 4.0-mm-diameter 30° arthroscope is used. Soft tissues around the talus are cleared with a motorized shaver and a radiofrequency device. The posterior aspects of the talus, os trigonum, and FHL tendon surrounded by the tendon sheath are visualized. The dynamic pathology of the FHL tendon is well observed on passive motion of the great toe. The prominent bone fragment of the talus is removed and the tendon sheath is cut with a retrograde knife and a motorized shaver from the superior border down to the entrance of the fibro-osseous tunnel. Arthroscopic release of the FHL tendon sheath is a useful and easy method to directly approach the dynamic pathology of FHL tenosynovitis in female ballet dancers.

  9. Hypertrophy of the extra-articular tendon of the long head of biceps correlates with the location and size of a rotator cuff tear.

    Science.gov (United States)

    Takahashi, N; Sugaya, H; Matsuki, K; Miyauchi, H; Matsumoto, M; Tokai, M; Onishi, K; Hoshika, S; Ueda, Y

    2017-06-01

    The aim of this study was to assess hypertrophy of the extra-articular tendon of the long head of biceps (LHB) in patients with a rotator cuff tear. The study involved 638 shoulders in 334 patients (175 men, 159 women, mean age 62.6 years; 25 to 81) with unilateral symptomatic rotator cuff tears. The cross-sectional area (CSA) of the LHB tendon in the bicipital groove was measured pre-operatively in both shoulders using ultrasound. There were 154 asymptomatic rotator cuff tears in the contralateral shoulder. Comparisons were made between those with a symptomatic tear, an asymptomatic tear and those with no rotator cuff tear. In the affected shoulders, the CSAs were compared in relation to the location and size of the rotator cuff tear. The mean CSA was 21.0 mm 2 (4 to 71) in those with a symptomatic rotator cuff tear, 19.9 mm 2 (4 to 75) in those with an asymptomatic rotator cuff tear and 14.1 mm 2 (5 to 43) in those with no rotator cuff tear. The mean CSA in patients with both symptomatic and asymptomatic rotator cuff tears was significantly larger than in those with no rotator cuff tear (p cuff tear and those with an antero-superior cuff tear. Regardless of the symptoms, there was significant hypertrophy of the extra-articular LHB tendon in patients with a rotator cuff tear. The values were significantly related to the size of the tear. Cite this article: Bone Joint J 2017;99-B:806-11. ©2017 The British Editorial Society of Bone & Joint Surgery.

  10. US Findings of Biceps Tendinitis: Cross Sectional Area Measurements of Long Head of Biceps Brachii

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Jong Soo; Seo, Kyung Mook; Lee, Hwa Yeon; Song, In Sup [ChungAng University College of Medicine, Seoul (Korea, Republic of); Yoo, Seung Min [Bundang Cha Hospital, Bundang (Korea, Republic of)

    2009-12-15

    The purpose of this study was to describe typical sonographic findings in patients with biceps tendinitis. Seventy five patients who had been clinically diagnosed with biceps tendinitis were included. Of the 75, 37 were male, 38 were female, and their mean age was 56 {+-} 9.74. The patients complained of shoulder pain and ultrasonography was performed for bilateral shoulders in all patients. The cross sectional area of the biceps tendon was measured. The status of fluid collection around the biceps tendon and accompanying rotator cuff disease were also investigated. The cross sectional areas of the diseased biceps tendon were 0.18 {+-} 0.09 cm2 (range: 0.07-0.42), and the areas of the normal side was 0.11 {+-} 0.05 cm2 (0.03-0.24). The cross sectional area of the diseased biceps tendon was 0.075 {+-} 0.062 cm2 greater, on average, than the uninvolved site (p < 0.01). Thirty six patients(48%) had fluid collection around the inflamed biceps tendon, and 30 patients had accompanied rotator cuff disease. During US examination of the shoulder in patients complaining of shoulder pain, if the cross sectional area of the biceps tendon in the painful shoulder is asymmetrically and larger than the contralateral tendon, biceps tendonitis is suggested

  11. US Findings of Biceps Tendinitis: Cross Sectional Area Measurements of Long Head of Biceps Brachii

    International Nuclear Information System (INIS)

    Shin, Jong Soo; Seo, Kyung Mook; Lee, Hwa Yeon; Song, In Sup; Yoo, Seung Min

    2009-01-01

    The purpose of this study was to describe typical sonographic findings in patients with biceps tendinitis. Seventy five patients who had been clinically diagnosed with biceps tendinitis were included. Of the 75, 37 were male, 38 were female, and their mean age was 56 ± 9.74. The patients complained of shoulder pain and ultrasonography was performed for bilateral shoulders in all patients. The cross sectional area of the biceps tendon was measured. The status of fluid collection around the biceps tendon and accompanying rotator cuff disease were also investigated. The cross sectional areas of the diseased biceps tendon were 0.18 ± 0.09 cm2 (range: 0.07-0.42), and the areas of the normal side was 0.11 ± 0.05 cm2 (0.03-0.24). The cross sectional area of the diseased biceps tendon was 0.075 ± 0.062 cm2 greater, on average, than the uninvolved site (p < 0.01). Thirty six patients(48%) had fluid collection around the inflamed biceps tendon, and 30 patients had accompanied rotator cuff disease. During US examination of the shoulder in patients complaining of shoulder pain, if the cross sectional area of the biceps tendon in the painful shoulder is asymmetrically and larger than the contralateral tendon, biceps tendonitis is suggested

  12. Evaluation of the results from arthroscopic tenodesis of the long head of the biceps brachii on the tendon of the subscapularis muscle

    Directory of Open Access Journals (Sweden)

    Marcelo Baggio

    2016-04-01

    Full Text Available OBJECTIVES: The aim of this study was to evaluate the results from arthroscopic tenodesis of the long head of the biceps brachii (LHBB on the tendon of the subscapularis muscle, with regard to the presence of pain, subscapularis lesion, presence of Popeye's sign and patient satisfaction. METHODS: A prospective cohort study was conducted on 32 patients with LHBB lesions, through preoperative interviews and physical examinations, which were repeated six months after the operation. The main variables studied were the belly press, bear hug and lift-off tests, Popeye's sign, anterior pain and satisfaction. The data were entered into Epi Info 3.5.4 and SPSS 18.0. In order to investigate the variables of interest, the chi-square, Student t and Kruskal-Wallis tests were used. The confidence interval was 95% and p values less than 0.05 were taken to be statistically significant. RESULTS: 32 patients of median age 57.5 years were evaluated. Anterior pain was reported by one interviewee after the operation. The tests for evaluating subscapularis lesions did not show any damage to this musculature after the surgery. Popeye's sign was negative in all the patients. The patient satisfaction rate reached 90.6% of the interviewees. CONCLUSION: This study showed that the new surgical technique described here presented excellent performance, without any subscapularis lesion and without identifying Popeye's sign. Only 3.1% of the patients had complaints of residual pain. The high level of satisfaction among the patients after the surgery confirms the results presented.

  13. Investigation of a robust tendon-sheath mechanism for flexible membrane wing application in mini-UAV

    Science.gov (United States)

    Lee, Shian; Tjahjowidodo, Tegoeh; Lee, Hsuchew; Lai, Benedict

    2017-02-01

    Two inherent issues manifest themselves in flying mini-unmanned aerial vehicles (mini-UAV) in the dense area at tropical climate regions, namely disturbances from gusty winds and limited space for deployment tasks. Flexible membrane wing (FMW) UAVs are seen to be potentials to mitigate these problems. FMWs are adaptable to gusty airflow as the wings are able to flex according to the gust load to reduce the effective angle-of-attack, thus, reducing the aerodynamic loads on the wing. On the other hand, the flexible structure is allowing the UAV to fold in a compact package, and later on, the mini-UAV can be deployed instantly from the storage tube, e.g. through a catapult mechanism. This paper discusses the development of an FMW UAV actuated by a tendon-sheath mechanism (TSM). This approach allows the wing to morph to generate a rolling moment, while still allowing the wing to fold. Dynamic characteristics of the mechanism that exhibits the strong nonlinear phenomenon of friction on TSM are modeled and compensated for. A feed-forward controller was implemented based on the identified nonlinear behavior to control the warping position of the wing. The proposed strategy is validated experimentally in a wind tunnel facility by creating a gusty environment that is imitating a realistic gusty condition based upon the results of computational fluid dynamics (CFD) simulation. The results demonstrate a stable and robust wing-warping actuation, even in gusty conditions. Accurate wing-warping can be achieved via the TSM, while also allowing the wings to fold.

  14. Tuberculose refratária disseminada com acometimento do tendão bicipital em paciente imunocompetente Disseminated refractary tuberculosis with biceps tendon involvement in an immunocompetent patient

    Directory of Open Access Journals (Sweden)

    Marcelo dos Reis Oliveira

    2009-06-01

    Full Text Available OBJETIVO: Relatar um caso raro de tuberculose disseminada em paciente imunocompetente, que evoluiu, durante o tratamento medicamentoso padrão, com envolvimento do tendão da porção longa do bíceps e da articulação do ombro. MÉTODOS: À primeira avaliação, o diagnóstico correto não foi feito e o paciente foi tratado com fisioterapia para tendinopatia do manguito rotador. Entretanto, apresentou rápida formação de massa na região anterior do terço proximal do braço e piora da dor. A punção da massa revelou líquido amarelado, cuja análise laboratorial confirmou tratar-se de infecção por M. tuberculosis. RESULTADOS: O paciente foi tratado com desbridamento cirúrgico e troca do esquema medicamentoso e evoluiu com resolução do quadro infeccioso e melhora completa da função do ombro direito. CONCLUSÃO: Devido a sua alta prevalência no Brasil, a tuberculose deve sempre ser considerada no diagnóstico diferencial dos casos de comprometimento crônico e progressivo das articulações, ossos, músculos, tendões e bursas, mesmo em indivíduos imunocompetentes.OBJECTIVE: The authors report a rare case of disseminated tuberculosis which had compromised the long head of biceps tendon and shoulder joint, during standard drug therapy. METHODS: On a first sight, the accurate diagnosis wasn't accomplished and the patient had been treated with physiotherapy for rotator cuff tear. However, the patient presented with a fast growing mass in anterior region of the proximal third of the arm, complaining of pain increase. Aspirative punction of the mass revealed a yellow fluid and the laboratorial analysis confirmed infection by M. Tuberculosis. The patient was treated with surgical debridement and his drug therapy was changed. RESULTS: Resolution of infectious status and complete shoulder function restoration was succeeded. CONCLUSION: Due to its high prevalence in Brazil, tuberculosis must always be considered as a possible cause of

  15. Imaging in a case of giant cell tumor of tendon sheath in foot: A case report with re-view of literature

    Directory of Open Access Journals (Sweden)

    Sujata Patnaik

    2014-07-01

    Full Text Available Large sized Giant cell tumors (GCT of the tendon sheaths of the foot are rare. We present a case with a large tumor over the dor-sum of foot which was diagnosed and studied by plain radiog-raphy, Ultrasound, CT and MRI scans. It was histologically con-firmed on biopsy. When the size of the tumor (like Giant cell tu-mor is too large and spread over multiple bones of the foot MRI is the imaging modality of choice to precisely define the anatomy to help in taking surgical decisions.

  16. Attrition tendinitis of long head of biceps brachii in relation to humeral head osteonecrosis: case report.

    Science.gov (United States)

    Wiesler, Ethan R; Sarlikiotis, Thomas; Mavrogenis, Andreas F; Kokkalis, Zinon T

    2013-01-01

    This case report identifies a 41-year-old male patient who developed anterior shoulder pain in the setting of humeral head osteonecrosis. As a consequence of the cartilage degeneration, multiple loose bodies formed and migrated into the bicipital tendon sheath, causing attrition tendinitis, which was a feature of the clinical presentation. The patient was treated by a combination of arthroscopic glenohumeral joint debridement and open tenodesis of the biceps using a suture anchor. Follow-up revealed asymptomatic shoulder function by 18 months. This is the first report in the literature of bicipital tendinitis in the context of avascular necrosis of the shoulder.

  17. MR arthrographic findings in tenosynovitis of the long bicipital tendon of the shoulder

    International Nuclear Information System (INIS)

    Gueckel, C.; Nidecker, A.

    1998-01-01

    Purpose. To assess the MR arthrographic findings of bicipital tenosynovitis in correlation with arthroscopy. Design and patients. The shoulder MR arthrographies of 500 consecutive patients were retrospectively analyzed for signs of bicipital tenosynovitis and associated pathologies. Forty patients (8%) had MR evidence of bicipital tenosynovitis, but only 17 (3%) with arthroscopic confirmation were included in the study. The MR findings in these patients were compared with those of 10 patients with rotator cuff lesions but arthroscopically normal long biceps tendons. MR arthrography was performed with 10-15 ml of a 250 mmol/l gadoterate meglumine (Gd-DOTA) solution injected under fluoroscopic guidance, and transaxial, oblique coronal and sagittal MR sequences were obtained. Results. All 17 patients showed one or more abnormal findings: signal increase in the tendon with or without fusiform distension was seen in 12, surface irregularities in six, adhesions in 11 and noncommunicating effusions of the tendon sheath in six. Associated abnormalities of the rotator cuff were present in 16 while the seventeenth patient had glenohumeral synovitis without rotator cuff pathology. MR arthrograms correlated with arthroscopic findings in the joint but comparison was not possible in the intertubercular groove portion of the biceps tendon. None of the 10 patients with an arthroscopically normal biceps tendon showed any of the MR findings of bicipital tenosynovitis. Conclusion. Bicipital tenosynovitis is detectable by MR arthrography. In most cases it is an associated finding of rotator cuff abnormalities and likely to have a similar etiology. When lesions of the anterior rotator cuff are recognized, the biceps tendon should be scrutinized for inflammatory changes. (orig.)

  18. MR arthrographic findings in tenosynovitis of the long bicipital tendon of the shoulder

    Energy Technology Data Exchange (ETDEWEB)

    Gueckel, C. [Department of Radiology, University Hospital of Basel, Petersgraben 4, CH-4031 Basel (Switzerland); Nidecker, A. [MRI Institut Rebgasse, Untere Rebgasse 18, CH-4058 Basel (Switzerland)

    1998-01-01

    Purpose. To assess the MR arthrographic findings of bicipital tenosynovitis in correlation with arthroscopy. Design and patients. The shoulder MR arthrographies of 500 consecutive patients were retrospectively analyzed for signs of bicipital tenosynovitis and associated pathologies. Forty patients (8%) had MR evidence of bicipital tenosynovitis, but only 17 (3%) with arthroscopic confirmation were included in the study. The MR findings in these patients were compared with those of 10 patients with rotator cuff lesions but arthroscopically normal long biceps tendons. MR arthrography was performed with 10-15 ml of a 250 mmol/l gadoterate meglumine (Gd-DOTA) solution injected under fluoroscopic guidance, and transaxial, oblique coronal and sagittal MR sequences were obtained. Results. All 17 patients showed one or more abnormal findings: signal increase in the tendon with or without fusiform distension was seen in 12, surface irregularities in six, adhesions in 11 and noncommunicating effusions of the tendon sheath in six. Associated abnormalities of the rotator cuff were present in 16 while the seventeenth patient had glenohumeral synovitis without rotator cuff pathology. MR arthrograms correlated with arthroscopic findings in the joint but comparison was not possible in the intertubercular groove portion of the biceps tendon. None of the 10 patients with an arthroscopically normal biceps tendon showed any of the MR findings of bicipital tenosynovitis. Conclusion. Bicipital tenosynovitis is detectable by MR arthrography. In most cases it is an associated finding of rotator cuff abnormalities and likely to have a similar etiology. When lesions of the anterior rotator cuff are recognized, the biceps tendon should be scrutinized for inflammatory changes. (orig.) With 4 figs., 4 tabs., 22 refs.

  19. Biceps Autograft Augmentation for Rotator Cuff Repair : A Systematic Review

    NARCIS (Netherlands)

    Veen, Egbert J D; Stevens, Martin; Diercks, Ronald L

    Purpose: To improve surgical outcomes in patients with massive cuff defects, different techniques and augmentations are proposed. The biceps tendon is easily available as an autograft. Our aim was to conduct a qualitative systematic review of various methods and surgical techniques that use a biceps

  20. Clinical relevance of distal biceps insertional and footprint anatomy

    NARCIS (Netherlands)

    van den Bekerom, Michel P J; Kodde, Izaäk F.; Aster, Asir; Bleys, Ronald L A W; Eygendaal, Denise

    2016-01-01

    Purpose: The aim of this review was to present an overview, based on a literature search, of surgical anatomy for distal biceps tendon repairs, based on the current literature. Methods: A narrative review was performed using Pubmed/Medline using key words: Search terms were distal biceps,

  1. A meta-analysis comparing tenotomy and tenodesis for treating rotator cuff tears combined with long head of the biceps tendon lesions.

    Directory of Open Access Journals (Sweden)

    Xiliang Shang

    Full Text Available The purpose of this meta-analysis was to assess whether there were differences in the outcomes between tenotomy and tenodesis in treating LHBT lesions combined with rotator cuff repairs.Using Medline, Embase, and Cochrane, we searched for articles comparing tenotomy and tenodesis combined with rotator cuff repair which were published before April 2016 with the terms "biceps", "tenotomy", "tenodesis", and "rotator cuff". The controlled clinical studies that met the inclusion and exclusion criteria were assessed for quality of methodology by utilizing the Coleman score.On the basis of the inclusion and exclusion criteria, ten articles (903 patients were included in this meta-analysis. The Coleman score ranged between 40 and 89 in the included studies. The results showed that the incidence of the popeye sign (OR, 2.777, P = 0.000 were higher in tenotomy group compared with tenodesis group when concomitant rotator cuff repair. Statistically significant difference in favor of tenodesis was observed for Constant score (SMD, -0.230, P = 0.025. As for the arm cramping pain, patient satisfaction, VAS score, ASES score and UCLA increased score, the strength and the range of motion, there were no significant differences between tenodesis and tenotomy of the LHBT, corresponding to the currently available results in the literature.Based on this meta-analysis, both tenotomy and tenodesis are effective in pain relief and function improvement in patients with repairable rotator cuff tears. No significant differences in post-operative functional outcome between tenotomy and tenodesis for the treatment of LHBT lesions were observed except for a lower Constant score and higher risk of Popeye deformity in tenotomy.

  2. Biceps tendinitis caused by an osteochondroma in the bicipital groove: a rare cause of shoulder pain in a baseball player.

    Science.gov (United States)

    Onga, Takafumi; Yamamoto, Tetsuji; Akisue, Toshihiro; Marui, Takashi; Kurosaka, Masahiro

    2005-02-01

    Tendinitis of the long head of the biceps brachii muscle is commonly seen in athletes who do repetitive overhead motions. Common causes of biceps tendinitis include impingement syndrome, subluxation of the biceps tendon, and attrition tendinitis, whereas biceps tendinitis secondary to a bone neoplasm is rare. A case of biceps tendinitis caused by an osteochondroma arising in the left humeral bicipital groove in a 25-year-old male baseball player is reported. The tumor was hook-shaped, originated from the inferomedial portion of the humeral lesser tubercle, and surrounded the biceps tendon. Symptoms of increasing pain and inability to throw resulted from direct irritation of the biceps tendon by the tumor. Total excision of the tumor relieved the symptoms within 3 weeks. To our knowledge, there have been no reported cases in the English-language literature of biceps tendinitis caused by an osteochondroma.

  3. Simultaneous acute rotator cuff tear and distal biceps rupture in a strongman competitor.

    Science.gov (United States)

    George, Michael S

    2010-04-01

    Acute rotator cuff tear is commonly associated with tearing of the proximal biceps tendon, but has never been reported to occur simultaneously with a distal biceps tendon rupture. A 38-year-old right-hand-dominant strongman competitor attempted a 300-pound overhead axle press and experienced immediate pain in the right shoulder and elbow. He had no known systemic risk factors for tendon ruptures including hyperparathyroidism, hemodialysis, alcoholism, rheumatoid arthritis, statin medications, fluoroquinolones, and steroid use.Right shoulder magnetic resonance imaging (MRI) showed a full-thickness supraspinatus tear with 3 cm of retraction. There was minimal fatty infiltration of the supraspinatus on the sagittal cuts consistent with acute rupture. The subscapularis was intact. The long head of the biceps tendon had mild medial subluxation but was completely within the bicipital groove. Right elbow MRI showed a complete distal biceps tendon rupture. Thirteen days after his injury, the patient underwent arthroscopic supraspinatus repair and proximal biceps tenodesis. Distal biceps tendon repair was performed using the modified 2-incision muscle-splitting technique. At 24-month follow-up, the patient was pain free and had returned to full activity including weightlifting but had not returned to strongman competition.This is the first report of simultaneous acute full thickness ruptures of the rotator cuff and distal biceps tendon. This case report underscores the importance of a complete physical examination and a high index of suspicion for additional concomitant injuries, particularly in athletes with unusually high stresses to the body. Copyright 2010, SLACK Incorporated.

  4. Clinical aspects of tendon healing

    NARCIS (Netherlands)

    J.C.H.M. van der Meulen (Jacques)

    1974-01-01

    textabstractWe know that healing of a tendon wound takes place by an invasion of fibreblasts from the surrounding tissues; the tendon itself has no intrinsic healing capacity. lt was Potenza (1962) who proved that a traumatic suture of the tendons within their sheath is followed by disintegration of

  5. Primary tendinitis of the long head of the biceps.

    Science.gov (United States)

    Post, M; Benca, P

    1989-09-01

    Seventeen patients with chronic painful shoulders who showed evidence of isolated bicipital tendinitis involving only the extracapsular, intertubercular portion of the long head of the biceps were chosen for surgical treatment when conservative treatment failed. The patients were thought to have primary bicipital tendinitis. The latter condition is secondary to other shoulder pathologies. Thirteen patients had tenodeses and four patients had transfer of the long head of the biceps to the origin of the conjoined tendon. Overall, excellent and good results were noted in 94% of both groups of patients when the long head of the biceps was tenodesed or transferred. Whether or not the long head of the biceps is a significant depressor of the humeral head requires further investigation.

  6. Acute distal biceps rupture in an adolescent weightlifter on chronic steroid suppression: a case report.

    Science.gov (United States)

    Ding, David Y; LaMartina, Joey A; Zhang, Alan L; Pandya, Nirav K

    2016-09-01

    Distal biceps tendon ruptures are uncommon events in the adult population and exceedingly rare in the adolescent population. To the best of our knowledge, this is the first and only report of a distal biceps tendon rupture in an adolescent with a history of chronic corticosteroid suppression. We present a case of a 17-year-old male on chronic corticosteroid suppression who underwent a successful distal biceps tendon repair after an acute rupture following weightlifting. At the 1-year follow-up, the patient reports full range of motion and strength, and is able to return to his preinjury activity level with sports and weightlifting. Acute distal biceps ruptures are uncommon injuries in the pediatric population, but may occur in conjunction with chronic corticosteroid use. Anatomic repair, when possible, can restore function and strength. level IV, case report.

  7. Tumor de células gigantes de bainha de tendão no LCA Tendon sheath giant cells tumor in ACL

    Directory of Open Access Journals (Sweden)

    André Pedrinelli

    2007-01-01

    Full Text Available Trata-se de um relato de caso de tumor de células gigantes de bainha do ligamento cruzado anterior, uma localização extremamente rara para esse tipo de lesão. O paciente do sexo feminino apresentava dor no joelho, sem relato de trauma anterior. Foi submetido ao exame clínico, ao estudo radiográfico e de ressonância magnética da região. Feita a hipótese diagnóstica de TGC de Bainha, o paciente foi então tratado com ressecção artroscópica do tumor. O diagnóstico foi confirmado com exame anátomo-patológico. O paciente evoluiu bem, com melhora dos sintomas referidos no pré-operatório.The author presents a case report of Tumor Giant Cells (TGC localized on the anterior cruciate ligament sheath, an extremely rare site for this kind of lesion. A 37 y-o female patient presented with knee pain, with no history of previous trauma. She underwent clinical examination, X-ray study and magnetic resonance of the region. The diagnostic hypothesis of Sheath TGC was provided, and the patient was treated with tumor arthroscopy resection. Diagnosis was confirmed by anatomicopathological examination. By the end point assessment, none of the pre-operative symptoms were reported.

  8. Extraarticular variants of the long head of the biceps brachii: a reminder of embryology.

    Science.gov (United States)

    Audenaert, Emmanuel A; Barbaix, Erik J; Van Hoonacker, Petrus; Berghs, Bart M

    2008-01-01

    Developmental anomalies of the long head of the biceps tendon are rare and have been described in the literature mainly dealing with anatomy and embryology. Because most basic embryologic research on this topic was conducted before 1966, a literature search was performed from archived anatomy textbooks and manuscript references. These data were compared with the scarce case descriptions of developmental anomalies of the long head of the biceps tendon. An additional case illustration from our own experience was provided. From the literature, it appears that during the embryologic phase of development, a staged migration of the long head of the biceps tendon occurs from a position between the fibrous capsule and synovial layer to an intraarticular position. Recent anatomic and arthroscopic case reports have shown that interruption of this migration can occur in any of these stages. Given the recent increase in arthroscopic shoulder surgery, anomalies of the long head of the biceps tendon will be encountered more frequently. Knowledge of their existence and origin can help in evaluating unexpected anatomic variations or the absence of the biceps tendon in preoperative medical imaging or during an arthroscopic procedure.

  9. Nonsurgical giant cell tumour of the tendon sheath or of the diffuse type: Are MRI or 18F-FDG PET/CT able to provide an accurate prediction of long-term outcome?

    International Nuclear Information System (INIS)

    Dercle, Laurent; Chisin, Roland; Ammari, Samy; Gillebert, Quentin; Ouali, Monia; Jaudet, Cyril; Dierickx, Lawrence; Zerdoud, Slimane; Courbon, Frederic; Delord, Jean-Pierre; Schlumberger, Martin

    2015-01-01

    To investigate whether MRI (RECIST 1.1, WHO criteria and the volumetric approach) or 18 F-FDG PET/CT (PERCIST 1.0) are able to predict long-term outcome in nonsurgical patients with giant cell tumour of the tendon sheath or of the diffuse type (GCT-TS/DT). Fifteen ''nonsurgical'' patients with a histological diagnosis of GCT-TS/DT were divided into two groups: symptomatic patients receiving targeted therapy and asymptomatic untreated patients. All 15 patients were evaluated by MRI of whom 10 were treated, and a subgroup of 7 patients were evaluated by PET/CT of whom 4 were treated. Early evolution was assessed according to MRI and PET/CT scans at baseline and during follow-up. Cohen's kappa coefficient was used to evaluate the degree of agreement between PERCIST 1.0, RECIST 1.1, WHO criteria, volumetric approaches and the reference standard (long-term outcome, delay 505 ± 457 days). The response rate in symptomatic patients with GCT-TS/DT receiving targeted therapy was also assessed in a larger population that included additional patients obtained from a review of the literature. The kappa coefficients for agreement between RECIST/WHO/volumetric criteria and outcome (15 patients) were respectively: 0.35 (p = 0.06), 0.26 (p = 0.17) and 0.26 (p = 0.17). In the PET/CT subgroup (7 patients), PERCIST was in perfect agreement with the late symptomatic evolution (kappa = 1, p 18 F-FDG PET/CT with PERCIST is a promising approach to the prediction of the long-term outcome in GCT-TS/DT and may avoid unnecessary treatments, toxicity and costs. On MRI, WHO and volumetric approaches are not more effective than RECIST using the current thresholds. (orig.)

  10. Increased muscle belly and tendon stiffness in patients with Parkinson's disease, as measured by myotonometry.

    Science.gov (United States)

    Marusiak, Jarosław; Jaskólska, Anna; Budrewicz, Sławomir; Koszewicz, Magdalena; Jaskólski, Artur

    2011-09-01

    Based on Davis's law, greater tonus of the muscle belly in individuals with Parkinson's disease can create greater tension in the tendon, leading to structural adjustment and an increase in tendon stiffness. Our study aimed to separately assess passive stiffness in the muscle belly and tendon in medicated patients with Parkinson's disease, using myotonometry. We tested 12 patients with Parkinson's disease and 12 healthy matched controls. Passive stiffness of muscle belly and tendon was estimated by myotonometry, electromyography, and mechanomyography in relaxed biceps and triceps brachii muscles. Compared with controls, patients with Parkinson's disease had higher stiffness in the muscle belly and tendon of the biceps brachii and in the tendon of the triceps brachii. In patients with Parkinson's disease, there was a positive correlation between muscle belly stiffness and parkinsonian rigidity in the biceps brachii. Patients with Parkinson's disease have higher passive stiffness of the muscle belly and tendon than healthy matched controls. Copyright © 2011 Movement Disorder Society.

  11. MRI of tibialis anterior tendon rupture

    International Nuclear Information System (INIS)

    Gallo, Robert A.; DeMeo, Patrick J.; Kolman, Brett H.; Daffner, Richard H.; Sciulli, Robert L.; Roberts, Catherine C.

    2004-01-01

    Ruptures of the tibialis anterior tendon are rare. We present the clinical histories and MRI findings of three recent male patients with tibialis anterior tendon rupture aged 58-67 years, all of whom presented with pain over the dorsum of the ankle. Two of the three patients presented with complete rupture showing discontinuity of the tendon, thickening of the retracted portion of the tendon, and excess fluid in the tendon sheath. One patient demonstrated a partial tear showing an attenuated tendon with increased surrounding fluid. Although rupture of the tibialis anterior tendon is a rarely reported entity, MRI is a useful modality in the definitive detection and characterization of tibialis anterior tendon ruptures. (orig.)

  12. Tendoscopy of the peroneal tendons

    NARCIS (Netherlands)

    van Dijk, C. N.; Kort, N.

    1998-01-01

    An anatomic cadaver study was performed. Subsequently, in a prospective study, diagnostic and therapeutic tendoscopy (tendon sheath endoscopy) was performed in nine consecutive patients with a history of persistent posterolateral ankle pain for at least 6 months. All patients had pain on palpation

  13. A comparison of physical examinations with musculoskeletal ultrasound in the diagnosis of biceps long head tendinitis.

    Science.gov (United States)

    Chen, Hung-Sheng; Lin, Shu-Hsien; Hsu, Yen-Hsia; Chen, Shih-Ching; Kang, Jiunn-Horng

    2011-09-01

    Provocative tests are useful in diagnosing biceps tendon tendinitis. This is the first study to establish the reliability of these tests by comparing the resuts with musculoskeletal ultrasound (US) findings. This study examined 125 patients (69 women and 56 men) and 143 shoulders with shoulder pain. Yergason's test, Speed's test and a bicipital groove tenderness test were performed and musculoskeletal US findings were used as standard reference. Biceps tendon tendinitis was diagnosed with US in 39.1% of the patients and, of those, 55.3% had coexisting rotator cuff injury. The sensitivity and specificity of Yergason's test were 32% and 78%, respectively. The sensitivity and specificity of Speed's test were 63% and 58%, respectively. In conclusion, all three tests are limited by poor sensitivity. US can be an image modality choice in diagnosing biceps pathology. Copyright © 2011 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  14. Diagnostic glenohumeral arthroscopy fails to fully evaluate the biceps-labral complex.

    Science.gov (United States)

    Taylor, Samuel A; Khair, M Michael; Gulotta, Lawrence V; Pearle, Andrew D; Baret, Nikolas J; Newman, Ashley M; Dy, Christopher J; O'Brien, Stephen J

    2015-02-01

    The purpose of this study was to define the limits of diagnostic glenohumeral arthroscopy and determine the prevalence and frequency of hidden extra-articular "bicipital tunnel" lesions among chronically symptomatic patients. Eight fresh-frozen cadaveric specimens underwent diagnostic glenohumeral arthroscopy with percutaneous tagging of the long head of the biceps tendon (LHBT) during maximal tendon excursion. The percentage of visualized LHBT was calculated relative to the distal margin of subscapularis tendon and the proximal margin of the pectoralis major tendon. Then, a retrospective review of 277 patients who underwent subdeltoid transfer of the LHBT to the conjoint tendon were retrospectively analyzed for lesions of the biceps-labral complex. Lesions were categorized by anatomic location (inside, junctional, or bicipital tunnel). Inside lesions were labral tears. Junctional lesions were LHBT tears visualized during glenohumeral arthroscopy. Bicipital tunnel lesions were extra-articular lesions hidden from view during standard glenohumeral arthroscopy. Seventy-eight percent of LHBT were visualized relative to the distal margin of the subscapularis tendon and only 55% relative to the proximal margin of the pectoralis major tendon. No portion of the LHBT inferior to the subscapularis tendon was visualized. Forty-seven percent of patients had hidden bicipital tunnel lesions. Scarring was most common and accounted for 48% of all such lesions. Thirty-seven percent of patients had multiple lesion locations. Forty-five percent of patients with junctional lesions also had hidden bicipital tunnel lesions. The only offending lesion was in the bicipital tunnel for 18% of patients. Diagnostic glenohumeral arthroscopy fails to fully evaluate the biceps-labral complex because it visualizes only 55% of the LHBT relative to the proximal margin of the pectoralis major tendon and did not identify extra-articular bicipital tunnel lesions present in 47% of chronically

  15. MR Imaging and US of the Wrist Tendons.

    Science.gov (United States)

    Plotkin, Benjamin; Sampath, Srihari C; Sampath, Srinath C; Motamedi, Kambiz

    2016-10-01

    The tendons of the wrist are commonly symptomatic. They can be injured, infected, or inflamed. Magnetic resonance imaging and ultrasonography are useful tools for evaluating the wrist. Pathologic conditions of the wrist tendons include de Quervain tenosynovitis, extensor carpi ulnaris tendinopathy, rheumatoid tenosynovitis, infectious synovitis, tendon tears, hydroxyapatite deposition disease, intersection syndrome, tenosynovial giant cell tumor, and fibroma of the tendon sheath. In this article, we review the normal appearance of the wrist tendons, discuss relevant anatomy, and give an overview of common pathologic conditions affecting the wrist tendons. Online supplemental material is available for this article. © RSNA, 2016.

  16. Does Additional Biceps Augmentation Improve Rotator Cuff Healing and Clinical Outcomes in Anterior L-Shaped Rotator Cuff Tears? Clinical Comparisons With Arthroscopic Partial Repair.

    Science.gov (United States)

    Jeon, Yoon Sang; Lee, Juyeob; Kim, Rag Gyu; Ko, Young-Won; Shin, Sang-Jin

    2017-11-01

    The repair of anterior L-shaped tears is usually difficult because of the lack of anterior rotator cuff tendon to cover the footprint. The biceps tendon is usually exposed from the retracted anterolateral corner of the torn tendon and can be easily used to augment rotator cuff repair. Hypothesis/Purpose: This study compared the clinical outcomes of the biceps augmentation technique with those of partial tendon repair for the arthroscopic treatment of large anterior L-shaped rotator cuff tears to evaluate the role of additional biceps augmentation in tendon healing. We hypothesized that the biceps augmentation technique would lead to a lower rotator cuff tendon retear rate and provide satisfactory functional outcomes. Cohort study; Level of evidence, 3. This study included 64 patients with anterior L-shaped rotator cuff tears who underwent arthroscopic repair. Patients were divided into 2 groups: group A (31 patients) underwent repair of an anterior L-shaped tear combined with biceps augmentation, and group B (33 patients) had a partially repaired tendon whose footprint was exposed after repair without undue tension on the retracted tendon. Clinical evaluations were performed using the American Shoulder and Elbow Surgeons (ASES) score, Constant score, muscle strength, visual analog scale for pain, and patient satisfaction. Magnetic resonance imaging (MRI) was performed for tendon integrity at 6 months postoperatively. The mean period of follow-up was 29.1 ± 3.5 months (range, 24-40 months). The mean ASES and Constant scores significantly improved from 52.8 ± 10.6 and 43.2 ± 9.9 preoperatively to 88.2 ± 6.9 and 86.8 ± 6.2 at final follow-up in group A ( P rotation [ER]: 57.5 ± 9.9 to 86.8 ± 9.3; internal rotation [IR]: 68.1 ± 10.8 to 88.1 ± 8.4; P rotator cuff tendon on postoperative MRI. The retear rate between the 2 groups showed no significant difference ( P = .552). Regarding clinical outcomes, both groups had no significant difference in the ASES score

  17. IFSSH Flexor Tendon Committee report 2014: from the IFSSH Flexor Tendon Committee (Chairman: Jin Bo Tang).

    Science.gov (United States)

    Tang, Jin Bo; Chang, James; Elliot, David; Lalonde, Donald H; Sandow, Michael; Vögelin, Esther

    2014-01-01

    Hand surgeons continue to search for the best surgical flexor tendon repair and treatment of the tendon sheaths and pulleys, and they are attempting to establish postoperative regimens that fit diverse clinical needs. It is the purpose of this report to present the current views, methods, and suggestions of six senior hand surgeons from six different countries - all experienced in tendon repair and reconstruction. Although certainly there is common ground, the report presents provocative views and approaches. The report reflects an update in the views of the committee. We hope that it is helpful to surgeons and therapists in treating flexor tendon injuries.

  18. Is nonoperative management of partial distal biceps tears really successful?

    Science.gov (United States)

    Bauer, Tyler M; Wong, Justin C; Lazarus, Mark D

    2018-04-01

    The current treatment of partial distal biceps tears is a period of nonoperative management, followed by surgery, if symptoms persist. Little is known about the success rate and outcomes of nonoperative management of this illness. We identified 132 patients with partial distal biceps tears through an International Classification of Diseases, Ninth Revision code query of our institution's database. Patient records were reviewed to abstract demographic information and confirm partial tears of the distal biceps tendon based on clinical examination findings and confirmatory magnetic resonance imaging (MRI). Seventy-four patients completed an outcome survey. In our study, 55.7% of the contacted patients who tried a nonoperative course (34 of 61 patients) ultimately underwent surgery, and 13 patients underwent immediate surgery. High-need patients, as defined by occupation, were more likely to report that they recovered ideally if they underwent surgery, as compared with those who did not undergo surgery (odds ratio, 11.58; P = .0138). For low-need patients, the same analysis was not statistically significant (P = .139). There was no difference in satisfaction scores between patients who tried a nonoperative course before surgery and those who underwent immediate surgery (P = .854). An MRI-diagnosed tear of greater than 50% was a predictor of needing surgery (odds ratio, 3.0; P = .006). This study has identified clinically relevant information for the treatment of partial distal biceps tears, including the following: the failure rate of nonoperative treatment, the establishment of MRI percent tear as a predictor of failing nonoperative management, the benefit of surgery for the high-need occupational group, and the finding that nonoperative management does not negatively affect outcome if subsequent surgery is necessary. Copyright © 2018 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  19. Disorders of the long head of the biceps: tenotomy versus tenodesis.

    Science.gov (United States)

    Ribeiro, Fabiano Rebouças; Ursolino, André Petry Sandoval; Ramos, Vinicius Ferreira Lima; Takesian, Fernando Hovaguim; Tenor Júnior, Antonio Carlos; Costa, Miguel Pereira da

    2017-01-01

    Disorders of the long head of biceps tendon are common in clinical practice. Their causes could be degenerative, inflammatory, instability (subluxation or luxation) or traumatic. They are generally associated to other diseases of the shoulder, mainly rotator cuff injuries. Currently, there is controversy in the literature regarding the indications for surgical treatment and the choice of the best technique for each case, due to the possibility of esthetic deformity, loss of muscle strength, and residual pain. The objective of this study was to identify the indications for surgical treatment, the best surgical technique, and the advantages and disadvantages of each technique described in the orthopedic literature for the treatment of long head of biceps tendon injuries. A revision of the orthopedic medical literature on the following databases: Biblioteca Regional de Medicina (BIREME), Medline, PubMed, Cochrane Library and Google Scholar, comprising articles published in the period from 1991 to 2015.

  20. Bicep2. III. INSTRUMENTAL SYSTEMATICS

    International Nuclear Information System (INIS)

    Ade, P. A. R.; Aikin, R. W.; Bock, J. J.; Brevik, J. A.; Filippini, J. P.; Golwala, S. R.; Hildebrandt, S. R.; Barkats, D.; Benton, S. J.; Bischoff, C. A.; Buder, I.; Karkare, K. S.; Bullock, E.; Dowell, C. D.; Duband, L.; Fliescher, S.; Halpern, M.; Hasselfield, M.; Hilton, G. C.; Irwin, K. D.

    2015-01-01

    In a companion paper, we have reported a >5σ detection of degree scale B-mode polarization at 150 GHz by the Bicep2 experiment. Here we provide a detailed study of potential instrumental systematic contamination to that measurement. We focus extensively on spurious polarization that can potentially arise from beam imperfections. We present a heuristic classification of beam imperfections according to their symmetries and uniformities, and discuss how resulting contamination adds or cancels in maps that combine observations made at multiple orientations of the telescope about its boresight axis. We introduce a technique, which we call “deprojection,” for filtering the leading order beam-induced contamination from time-ordered data, and show that it reduces power in Bicep2's actual and null-test BB spectra consistent with predictions using high signal-to-noise beam shape measurements. We detail the simulation pipeline that we use to directly simulate instrumental systematics and the calibration data used as input to that pipeline. Finally, we present the constraints on BB contamination from individual sources of potential systematics. We find that systematics contribute BB power that is a factor of ∼10× below Bicep2's three-year statistical uncertainty, and negligible compared to the observed BB signal. The contribution to the best-fit tensor/scalar ratio is at a level equivalent to r = (3–6) × 10 −3

  1. Bicep2. III. INSTRUMENTAL SYSTEMATICS

    Energy Technology Data Exchange (ETDEWEB)

    Ade, P. A. R. [School of Physics and Astronomy, Cardiff University, Cardiff, CF24 3AA (United Kingdom); Aikin, R. W.; Bock, J. J.; Brevik, J. A.; Filippini, J. P.; Golwala, S. R.; Hildebrandt, S. R. [Department of Physics, California Institute of Technology, Pasadena, CA 91125 (United States); Barkats, D. [Joint ALMA Observatory, ESO, Santiago (Chile); Benton, S. J. [Department of Physics, University of Toronto, Toronto, ON (Canada); Bischoff, C. A.; Buder, I.; Karkare, K. S. [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street MS 42, Cambridge, MA 02138 (United States); Bullock, E. [Minnesota Institute for Astrophysics, University of Minnesota, Minneapolis, MN 55455 (United States); Dowell, C. D. [Jet Propulsion Laboratory, Pasadena, CA 91109 (United States); Duband, L. [SBT, Commissariat à l’Energie Atomique, Grenoble (France); Fliescher, S. [Department of Physics, University of Minnesota, Minneapolis, MN 55455 (United States); Halpern, M.; Hasselfield, M. [Department of Physics and Astronomy, University of British Columbia, Vancouver, BC (Canada); Hilton, G. C.; Irwin, K. D., E-mail: csheehy@uchicago.edu [National Institute of Standards and Technology, Boulder, CO 80305 (United States); Collaboration: Bicep2 Collaboration; and others

    2015-12-01

    In a companion paper, we have reported a >5σ detection of degree scale B-mode polarization at 150 GHz by the Bicep2 experiment. Here we provide a detailed study of potential instrumental systematic contamination to that measurement. We focus extensively on spurious polarization that can potentially arise from beam imperfections. We present a heuristic classification of beam imperfections according to their symmetries and uniformities, and discuss how resulting contamination adds or cancels in maps that combine observations made at multiple orientations of the telescope about its boresight axis. We introduce a technique, which we call “deprojection,” for filtering the leading order beam-induced contamination from time-ordered data, and show that it reduces power in Bicep2's actual and null-test BB spectra consistent with predictions using high signal-to-noise beam shape measurements. We detail the simulation pipeline that we use to directly simulate instrumental systematics and the calibration data used as input to that pipeline. Finally, we present the constraints on BB contamination from individual sources of potential systematics. We find that systematics contribute BB power that is a factor of ∼10× below Bicep2's three-year statistical uncertainty, and negligible compared to the observed BB signal. The contribution to the best-fit tensor/scalar ratio is at a level equivalent to r = (3–6) × 10{sup −3}.

  2. Arthroscopic proximal versus open subpectoral biceps tenodesis with arthroscopic repair of small- or medium-sized rotator cuff tears.

    Science.gov (United States)

    Yi, Young; Lee, Jong-Myoung; Kwon, Seok Hyun; Kim, Jeong-Woo

    2016-12-01

    The study was aimed to compare arthroscopic proximal biceps tenodesis and open subpectoral biceps tenodesis in repair of small or medium rotator cuff tears. Eighty-five patients underwent biceps tenodesis with arthroscopic repair of a rotator cuff tear, and 66 patients were followed for median of 26.8 (18-42) months with ultrasonography were reviewed. The arthroscopic biceps tenodesis group included 34 cases, and the open subpectoral biceps group included 32 cases. Patients were evaluated using visual analogue scale (VAS), American Shoulder and Elbow Surgeons (ASES), and constant scores. Rotator cuff repair and fixation of the biceps tendon were assessed by ultrasonography. Fixation failure and degree of deformity were evaluated by the pain in the bicipital groove and biceps apex distance (BAD). VAS score and tenderness at the bicipital groove decreased significantly in the open subpectoral group at 3 months postoperative. In both groups, the range of motion, ASES score, and constant score increased significantly (P tendinitis and using intra-bicipital groove tenodesis technique. III.

  3. Tendoscopy of the posterior tibial tendon

    NARCIS (Netherlands)

    van Dijk, C. N.; Kort, N.; Scholten, P. E.

    1997-01-01

    An anatomic cadaver study was performed and subsequently, in a prospective study, diagnostic and therapeutic tendoscopy (tendon sheath endoscopy) was performed in 16 consecutive patients with a history of persistent posteromedial ankle pain for at least 6 months. All patients had pain on palpation

  4. Communication through plasma sheaths

    International Nuclear Information System (INIS)

    Korotkevich, A. O.; Newell, A. C.; Zakharov, V. E.

    2007-01-01

    We wish to transmit messages to and from a hypersonic vehicle around which a plasma sheath has formed. For long distance transmission, the signal carrying these messages must be necessarily low frequency, typically 2 GHz, to which the plasma sheath is opaque. The idea is to use the plasma properties to make the plasma sheath appear transparent

  5. A Review of Recent Advances in the Diagnosis and Treatment Modalities for Long Head of Bicep Tendinopathy

    Directory of Open Access Journals (Sweden)

    Robert B. Lewis

    2016-01-01

    Full Text Available This article reviews the assessment and management of the pathology of the long head of the biceps tendon, a disease commonly encountered by primary care physicians and orthopedic surgeons. We include a discussion of relevant anatomy, function, pathoanatomy, natural history of the disease, diagnostic methods, and treatment options. Recent literature on the function of the long head of the bicep (LHB is reviewed. Literature on our evolving understanding of the pathoanatomy behind LHB tendinopathy is discussed. We also discuss the effectiveness of current diagnostic and treatment modalities.

  6. Role of tissue-engineered artificial tendon in healing of a large Achilles tendon defect model in rabbits.

    Science.gov (United States)

    Moshiri, Ali; Oryan, Ahmad; Meimandi-Parizi, Abdolhamid

    2013-09-01

    Treatment of large Achilles tendon defects is technically demanding. Tissue engineering is an option. We constructed a collagen-based artificial tendon, covered it with a polydioxanon (PDS) sheath, and studied the role of this bioimplant on experimental tendon healing in vivo. A 2-cm tendon gap was created in the left Achilles tendon of rabbits (n = 120). The animals were randomly divided into 3 groups: control (no implant), treated with tridimensional-collagen, and treated with tridimensional-collagen-bidimensional-PDS implants. Each group was divided into 2 subgroups of 60 and 120 days postinjury (DPI). Another 50 pilot animals were used to study the host-implant interaction. Physical activity of the animals was scored and ultrasonographic and bioelectrical characteristics of the injured tendons were investigated weekly. After euthanasia, macro, micro, and nano morphologies and biophysical and biomechanical characteristics of the healing tendons were studied. Treatment improved function of the animals, time dependently. At 60 and 120 DPI, the treated tendons showed significantly higher maximum load, yield, stiffness, stress, and modulus of elasticity compared with controls. The collagen implant induced inflammation and absorbed the migrating fibroblasts in the defect area. By its unique architecture, it aligned the fibroblasts and guided their proliferation and collagen deposition along the stress line of the tendon and resulted in improved collagen density, micro-amp, micro-ohm, water uptake, and delivery of the regenerated tissue. The PDS-sheath covering amplified these characteristics. The implants were gradually absorbed and replaced by a new tendon. Minimum amounts of peritendinous adhesion, muscle atrophy, and fibrosis were observed in the treated groups. Some remnants of the implants were preserved and accepted as a part of the new tendon. The implants were cytocompatible, biocompatible, biodegradable, and effective in tendon healing and regeneration. This

  7. Barrier cell sheath formation

    International Nuclear Information System (INIS)

    Kesner, J.

    1980-04-01

    The solution for electrostatic potential within a simply modeled tandem mirror thermal barrier is seen to exhibit a sheath at each edge of the cell. The formation of the sheath requires ion collisionality and the analysis assmes that the collisional trapping rate into the barrier is considerably slower than the barrier pump rate

  8. Generalization of proposed tendon friction correlation and its application to PCCV structural analysis

    International Nuclear Information System (INIS)

    Kashiwase, Takako; Nagasaka, Hideo

    2000-01-01

    The present paper dealt with the extension of tendon friction coefficient correlation as a function of loading end load and circumferential angle, proposed in the former paper. The extended correlation further included the effects of the number of strands contacted with sheath, tendon diameter, politicization of tendon and tendon local curvature. The validity of the correlation was confirmed by several published measured data. The structural analysis of middle cylinder part of 1/4 PCCV (Prestressed Concrete Containment Vessel) model was conducted using the present friction coefficient correlation. The results were compared with the analysis using constant friction coefficient, focused on the tendon tension force distribution. (author)

  9. No Telescoping Effect with Dual Tendon Vibration.

    Directory of Open Access Journals (Sweden)

    Valeria Bellan

    Full Text Available The tendon vibration illusion has been extensively used to manipulate the perceived position of one's own body part. However, findings from previous research do not seem conclusive sregarding the perceptual effect of the concurrent stimulation of both agonist and antagonist tendons over one joint. On the basis of recent data, it has been suggested that this paired stimulation generates an inconsistent signal about the limb position, which leads to a perceived shrinkage of the limb. However, this interesting effect has never been replicated. The aim of the present study was to clarify the effect of a simultaneous and equal vibration of the biceps and triceps tendons on the perceived location of the hand. Experiment 1 replicated and extended the previous findings. We compared a dual tendon stimulation condition with single tendon stimulation conditions and with a control condition (no vibration on both 'upward-downward' and 'towards-away from the elbow' planes. Our results show a mislocalisation towards the elbow of the position of the vibrated arm during dual vibration, in line with previous results; however, this did not clarify whether the effect was due to arm representation contraction (i.e., a 'telescoping' effect. Therefore, in Experiment 2 we investigated explicitly and implicitly the perceived arm length during the same conditions. Our results clearly suggest that in all the vibration conditions there was a mislocalisation of the entire arm (including the elbow, but no evidence of a contraction of the perceived arm length.

  10. Magnetic Resonance Imaging Currently Fails to Fully Evaluate the Biceps-Labrum Complex and Bicipital Tunnel.

    Science.gov (United States)

    Taylor, Samuel A; Newman, Ashley M; Nguyen, Joseph; Fabricant, Peter D; Baret, Nikolas J; Shorey, Mary; Ramkumar, Prem; O'Brien, Stephen J

    2016-02-01

    To determine the diagnostic accuracy of magnetic resonance imaging (MRI) for biceps-labrum complex (BLC) lesions, including the extra-articular bicipital tunnel. A retrospective review of 277 shoulders with chronic refractory BLC symptoms that underwent arthroscopic subdeltoid transfer of the long head of the biceps tendon (LHBT) to the conjoint tendon was conducted. Intraoperative lesions were categorized as "inside" (labral tears and dynamic LHBT incarceration), "junctional" (LHBT partial tears, LHBT subluxation, and biceps chondromalacia), or "bicipital tunnel" (extra-articular bicipital tunnel scar/stenosis, loose bodies, LHBT instability, and LHBT partial tears) based on anatomic location. Attending radiologist-generated MRI reports were graded dichotomously as positive or negative for biceps and labral damage and then compared with intraoperative findings. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated for MRI with respect to intraoperative findings. With regard to inside lesions, MRI had an overall sensitivity, specificity, PPV, and NPV for labrum lesions of 77.3%, 68.2%, 57.3%, and 84.5% respectively. The sensitivity, specificity, PPV, and NPV of MRI for junctional lesions were 43.3%, 55.6%, 73.1%, and 26.0%, respectively. For the bicipital tunnel, MRI had a sensitivity, specificity, PPV, and NPV of 50.4%, 61.4%, 48.7%, and 63.0%, respectively. MRI was unreliable for ruling out BLC lesions among chronically symptomatic patients, including when the bicipital tunnel was affected. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  11. Neglected ruptured flexor carpi ulnaris tendon mimics a soft tissue tumor in the wrist.

    Science.gov (United States)

    Rau, Chi-Lun; Yen, Tze-Hsun; Wu, Lien-Chen; Huang, Yi-You; Jaw, Fu-Shan; Liou, Tsan-Hon

    2014-04-01

    A wrist mass is rarely caused by a ruptured tendon in the forearm. The common pathologies are ganglia, tendon tenosynovitis, and giant cell tumors of tendon sheaths. Less common causes are nerve sheath tumors, vascular lesions, or an accessory muscle belly. The authors investigated a case of neglected ruptured flexor carpi ulnaris tendon that mimics a mass in the wrist. To the authors' knowledge, this is the first case report in relevant literature. During investigation, the high-resolution musculoskeletal ultrasound suggested a soft tissue tumor or a ruptured flexor carpi ulnaris tendon. The magnetic resonance imaging scan indicated an accessory flexor carpi ulnaris muscle belly. The diagnosis of ruptured flexor carpi ulnaris tendon was confirmed by surgical exploration. This case indicates that ultrasound may be better suited than magnetic resonance imaging in evaluating a wrist mass for its accuracy, availability, and portability.

  12. Healing of the Achilles tendon in rabbits--evaluation by magnetic resonance imaging and histopathology.

    Science.gov (United States)

    Tavares, Wilson Campos; de Castro, Ubiratam Brum; Paulino, Eduardo; Vasconcellos, Leonardo de Souza; Madureira, Ana Paula; Magalhães, Maria Angélica Baron; Mendes, Daniel Victor Moreira; Kakehasi, Adriana Maria; Resende, Vivian

    2014-12-12

    Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) could provide valuable findings for tendon regeneration. A non-invasive image method that can effectively evaluate the quality of the scar tissue has not yet been employed. Thirteen New Zealand rabbits were divided into two groups: group 1--non-treated control (n = 4); group 2--surgical intervention (n = 9). The central portion of the Achilles tendon was resected, and after 30 days, DCE-MRI was performed. Contrast enhancement methods were applied using the region of interest (ROI) technique. In the medium third of the Achilles tendon, the intra-substantial signal intensity and the presence of hyper-intense intra-tendon focus points and of signal heterogeneity were evaluated. Antero-posterior and transversal diameters of the tendon were measured. The Achilles tendon was removed and dissected free from other tissues. Sections from the central part of the tendon were stained for histological analysis. The difference between the contrast enhancement curves of the control and surgical groups (p tendon sheath, which presented irregular contours and intense contrast enhancement. On histology, the Achilles tendon presented diffuse widening of the tendon sheath and wedge-shaped areas with scarring tissue rich in disordered collagen fibres. These findings were related to alteration in the intra-substantial signal intensity, with hyper-signal focus points in the DCE-MRI. MRI with perfusion could be a useful technique for evaluating tissue and fibrous scarring in tendons.

  13. Composite inflation confronts BICEP2 and PLANCK

    International Nuclear Information System (INIS)

    Karwan, Khamphee; Channuie, Phongpichit

    2014-01-01

    We examine observational constraints on single-field inflation in which the inflaton is a composite field stemming from a four-dimensional strongly interacting field theory. We confront the predictions with the Planck and very recent BICEP2 data. In the large non-minimal coupling regions, we discover for the minimal composite inflationary model that the predictions lie well inside the joint 68% CL for the Planck data, but is in tension with the recent BICEP2 observations. In the case of the glueball inflationary model, the predictions satisfy the Planck results. However, this model can produce a large tensor-to-scalar ratio consistent with the recent BICEP2 observations if the number of e-foldings is slightly smaller than the range commonly used. For a super Yang-Mills paradigm, we discover that the predictions satisfy the Planck data, and surprisingly a large tensor-to-scalar ratio consistent with the BICEP2 results can also be produced for an acceptable range of the number of e-foldings and of the confining scale. In the small non-minimal coupling regions, all of the models can satisfy the BICEP2 results. However, the predictions of the glueball and superglueball inflationary models cannot satisfy the observational bound on the amplitude of the curvature perturbation launched by Planck, and the techni-inflaton self-coupling in the minimal composite inflationary model is constrained to be extremely small

  14. Tuberculosis tenosynovitis of the extensor tendons of the wrist

    OpenAIRE

    Mrabet, Dalila; Ouenniche, Kmar; Mizouni, Habiba; Ounaies, Mouna; Khémiri, Chékib; Sahli, Héla; Sellami, Slaheddine

    2011-01-01

    Mycobacterial tuberculous tenosynovitis of the extensor tendon sheath is an extremely rare manifestation of extrapulmonary tuberculosis. The diagnosis may be easily delayed because of its non-specific clinical signs. We report a new case of tuberculous tenosynovitis of the extensor without concomitant pulmonary tuberculosis or documented immunodeficiency.

  15. Tubercular tenosynovitis of extensor tendons of foot--a rare ...

    African Journals Online (AJOL)

    Tuberculosis of soft tissues as a result of spread from adjacent bone or joint is a well recognized entity. However isolated tuberculous pyomyositis, bursitis and tenosynovitis are rare, constituting about 1% of skeletal tuberculosis. Tubercular tenosynovitis commonly involves tendon sheaths of wrist and hand. Cases of ...

  16. Biomechanics of the Proximal Radius Following Drilling of the Bicipital Tuberosity to Mimic Cortical Button Distal Biceps Repair Technique.

    Science.gov (United States)

    Oak, Nikhil R; Lien, John R; Brunfeldt, Alexander; Lawton, Jeffrey N

    2018-05-01

    A fracture through the proximal radius is a theoretical concern after cortical button distal biceps fixation in an active patient. The permanent, nonossified cortical defect and medullary tunnel is at risk during a fall eliciting rotational and compressive forces. We hypothesized that during simulated torsion and compression, in comparison with unaltered specimens, the cortical button distal biceps repair model would have decreased torsional and compressive strength and would fracture in the vicinity of the bicipital tuberosity bone tunnel. Sixteen fourth-generation composite radius Sawbones models were used in this controlled laboratory study. A bone tunnel was created through the bicipital tuberosity to mimic the exact bone tunnel, 8 mm near cortex and 3.2 mm far cortex, made for the BicepsButton distal biceps tendon repair. The radius was then prepared and mounted on either a torsional or compression testing device and compared with undrilled control specimens. Compression tests resulted in average failure loads of 9015.2 N in controls versus 8253.25 N in drilled specimens ( P = .074). Torsional testing resulted in an average failure torque of 27.3 Nm in controls and 19.3 Nm in drilled specimens ( P = .024). Average fracture angle was 35.1° in controls versus 21.1° in drilled. Gross fracture patterns were similar in compression testing; however, in torsional testing all fractures occurred through the bone tunnel in the drilled group. There are weaknesses in the vicinity of the bone tunnel in the proximal radius during biomechanical stress testing which may not be clinically relevant in nature. In cortical button fixation, distal biceps repairs creates a permanent, nonossified cortical defect with tendon interposed in the bone tunnel, which can alter the biomechanical properties of the proximal radius during compressive and torsional loading.

  17. Anterior Interosseous Nerve Neuropraxia Secondary to Shoulder Arthroscopy and Open Subpectoral Long Head Biceps Tenodesis

    Directory of Open Access Journals (Sweden)

    Jeremiah T. Steed

    2017-01-01

    Full Text Available Arthroscopic rotator cuff tendon repair is a common elective procedure performed by trained orthopaedic surgeons with a relatively low complication rate. Specifically, isolated neuropraxia of the anterior interosseous nerve (AIN is a very rare complication of shoulder arthroscopy. An analysis of peer-reviewed published literature revealed only three articles reporting a total of seven cases that describe this specific complication following standard shoulder arthroscopic procedures. This article reports on three patients diagnosed with AIN neuropraxia following routine shoulder arthroscopy done by a single surgeon within a three-year period. All three patients also underwent open biceps tenodesis immediately following completion of the arthroscopic procedures. The exact causal mechanism of AIN neuropraxia following shoulder arthroscopy with biceps tenodesis is not known. This case report reviews possible mechanisms with emphasis on specific factors that make a traction injury the most likely etiology in these cases. We critically analyze our operating room setup and patient positioning practices in light of the existing biomechanical and cadaveric research to propose changes to our standard practices that may help to reduce the incidence of this specific postoperative complication in patients undergoing elective shoulder arthroscopy with biceps tenodesis.

  18. Iliopsoas Tendon Reformation after Psoas Tendon Release

    Directory of Open Access Journals (Sweden)

    K. Garala

    2013-01-01

    Full Text Available Internal snapping hip syndrome, or psoas tendonitis, is a recognised cause of nonarthritic hip pain. The majority of patients are treated conservatively; however, occasionally patients require surgical intervention. The two surgical options for iliopsoas tendinopathy are step lengthening of the iliopsoas tendon or releasing the tendon at the lesser trochanter. Although unusual, refractory snapping usually occurs soon after tenotomy. We report a case of a 47-year-old active female with internal snapping and pain following an open psoas tenotomy. Postoperatively she was symptom free for 13 years. An MRI arthrogram revealed reformation of a pseudo iliopsoas tendon reinserting into the lesser trochanter. The pain and snapping resolved after repeat iliopsoas tendon release. Reformation of tendons is an uncommon sequela of tenotomies. However the lack of long-term studies makes it difficult to calculate prevalence rates. Tendon reformation should be included in the differential diagnosis of failed tenotomy procedures after a period of symptom relief.

  19. A functional-anatomical approach to the spine-pelvis mechanism: interaction between the biceps femoris muscle and the sacrotuberous ligament.

    Science.gov (United States)

    van Wingerden, J P; Vleeming, A; Snijders, C J; Stoeckart, R

    1993-10-01

    Summary. Sacroiliac joint dysfunction is often overlooked as a possible cause of low back pain. This is due to the use of reductionistic anatomical models. From a kinematic point of view, topographic anatomical models are generally inadequate since they categorize pelvis, lower vertebral column and legs as distinct entities. This functional-anatomical study focuses on the question whether anatomical connections between the biceps femoris muscle and the sacrotuberous ligament are kinematically useful. Forces applied to the tendon of the biceps femoris muscle, simulating biceps femoris muscle force, were shown to influence sacrotuberous ligament tension. Since sacrotuberous ligament tension influences sacroiliac joint kinematics, hamstring training could influence the sacroiliac joint and thus low back kinematics. The clinical implications with respect to 'short' hamstrings, pelvic instability and walking are discussed.

  20. Magnetic resonance imaging of the elbow. Part II: Abnormalities of the ligaments, tendons, and nerves

    Energy Technology Data Exchange (ETDEWEB)

    Kijowski, Richard; Tuite, Michael; Sanford, Matthew [University of Wisconsin Hospital, Department of Radiology, Madison, WI (United States)

    2005-01-01

    Part II of this comprehensive review on magnetic resonance imaging of the elbow discusses the role of magnetic resonance imaging in evaluating patients with abnormalities of the ligaments, tendons, and nerves of the elbow. Magnetic resonance imaging can yield high-quality multiplanar images which are useful in evaluating the soft tissue structures of the elbow. Magnetic resonance imaging can detect tears of the ulnar collateral ligament and lateral collateral ligament of the elbow with high sensitivity and specificity. Magnetic resonance imaging can determine the extent of tendon pathology in patients with medial epicondylitis and lateral epicondylitis. Magnetic resonance imaging can detect tears of the biceps tendon and triceps tendon and can distinguishing between partial and complete tendon rupture. Magnetic resonance imaging is also helpful in evaluating patients with nerve disorders at the elbow. (orig.)

  1. Tenodesis of the long head of the biceps brachii for chronic bicipital tendinitis. Long-term results.

    Science.gov (United States)

    Becker, D A; Cofield, R H

    1989-03-01

    Fifty-four shoulders in fifty-one patients were followed for an average of thirteen years (range, two to twenty-three years) after surgical tenodesis of the long head of the biceps brachii for the treatment of chronic tendinitis. At an average of six months postoperatively, in all but three shoulders (forty-eight patients) some benefit was evident. However, after a longer follow-up, a satisfactory result was achieved in only twenty-eight shoulders (approximately 50 per cent). About one-third of the shoulders continued to be pain-free, and in eight shoulders (15 per cent) an additional operation was performed. Tenodesis of the long head of the biceps tendon, therefore, was not an effective treatment for tendinitis over the long term.

  2. Faraday scaling and the Bicep2 observations

    CERN Document Server

    Giovannini, Massimo

    2014-01-01

    As repeatedly speculated in the past, the linear polarization of the Cosmic Microwave Background can be rotated via the Faraday effect. An economic explanation of the recent Bicep2 observations, not relying on long-wavelength tensor modes of the geometry, would stipulate that the detected B mode comes exclusively from a Faraday rotated E mode polarization. We show hereunder that this interpretation is ruled out by the existing upper limits on the B mode polarization obtained by independent experiments at observational frequencies much lower than the operating frequency of the Bicep2 experiment. We then derive the fraction of the observed B mode polarization ascribable to the Faraday effect and suggest a dedicated experimental strategy for its detection.

  3. A practical, evidence-based, comprehensive (PEC) physical examination for diagnosing pathology of the long head of the biceps.

    Science.gov (United States)

    Rosas, Samuel; Krill, Michael K; Amoo-Achampong, Kelms; Kwon, KiHyun; Nwachukwu, Benedict U; McCormick, Frank

    2017-08-01

    Clinical examination of the shoulder joint has gained attention as clinicians aim to use an evidence-based examination of the biceps tendon, with the desire for a proper diagnosis while minimizing costly imaging procedures. The purpose of this study is to create a decision tree analysis that enables the development of a clinical algorithm for diagnosing long head of biceps (LHB) pathology. A literature review of Level I and II diagnostic studies was conducted to extract characteristics of clinical tests for LHB pathology through a systematic review of PubMed, Medline, Ovid, and Cochrane Review databases. Tests were combined in series and parallel to determine sensitivities and specificities, and positive and negative likelihood ratios were determined for each combination using a subjective pretest probability. The "gold standard" for diagnosis in all included studies was arthroscopy or arthrotomy. The optimal testing modality was use of the uppercut test combined with the tenderness to palpation of the biceps tendon test. This combination achieved a sensitivity of 88.4% when performed in parallel and a specificity of 93.8% when performed in series. These tests used in combination optimize post-test probability accuracy greater than any single individual test. Performing the uppercut test and biceps groove tenderness to palpation test together has the highest sensitivity and specificity of known physical examinations maneuvers to aid in the diagnosis of LHB pathology compared with diagnostic arthroscopy (practical, evidence-based, comprehensive examination). A decision tree analysis aides in the practical, evidence-based, comprehensive examination diagnostic accuracy post-testing based on the ordinal scale pretest probability. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  4. Separation and estimation of muscle spindle and tension receptor populations by vibration of the biceps muscle in the frog.

    Science.gov (United States)

    Giszter, S F; Kargo, W J

    2002-10-01

    Frog spinal cord reflex behaviors have been used to test the idea of spinal primitives. We have suggested a significant role for proprioception in regulation of primitives. However the in vivo behavior of spindle and golgi tendon receptors in frogs in response to vibration are not well described and the proportions of these proprioceptors are not established. In this study, we examine the selectivity of muscle vibration in the spinal frog. The aim of the study was (1) to examine how hindlimb muscle spindles and GTO receptors are activated by muscle vibration and (2) to estimate the relative numbers of GTO receptors and spindle afferents in a selected muscle, for comparison with the mammal. Single muscle afferents from the biceps muscle were identified in the dorsal roots. These were tested in response to biceps vibration, intramuscular stimulation and biceps nerve stimulation. Biceps units were categorized into two types: First, spindle afferents which had a high conduction velocity (approximately 20-30 m/s), responded reliably (were entrained 1:1) to muscle vibration, and exhibited distinct pauses to shortening muscle contractions. Second, golgi tendon organ afferents, which had a lower conduction velocity (approximately 10-20 m/s), responded less reliably to muscle vibration at physiologic muscle lengths, but responded more reliably at extended lengths or with background muscle contraction, and exhibited distinct bursts to shortening muscle contractions. Vibration responses of these units were tested with and without muscle curarization. Ensemble (suction electrode) recordings from the dorsal roots were used to provide rough estimates of the proportions of the two muscle afferent types.

  5. Calcaneal tendon: imaging findings

    International Nuclear Information System (INIS)

    Montandon, Cristiano; Fonseca, Cristiano Rezio; Montandon Junior, Marcelo Eustaquio; Lobo, Leonardo Valadares; Ribeiro, Flavia Aparecida de Souza; Teixeira, Kim-Ir-Sen Santos

    2003-01-01

    We reviewed the radiological and clinical features of 23 patients with calcaneal tendon diseases, who were submitted to ultrasound or magnetic resonance imaging. The objective of this study was to characterize the lesions for a precise diagnosis of calcaneal tendon injuries. A wide range of calcaneal tendon diseases include degenerative lesions, inflammation of the peritendinous tissue such as peritendinitis and bursitis, and rupture. Imaging methods are essential in the diagnosis, treatment and follow-up of calcaneal tendon diseases. (author)

  6. Central Tendon Injuries of Hamstring Muscles: Case Series of Operative Treatment.

    Science.gov (United States)

    Lempainen, Lasse; Kosola, Jussi; Pruna, Ricard; Puigdellivol, Jordi; Sarimo, Janne; Niemi, Pekka; Orava, Sakari

    2018-02-01

    As compared with injuries involving muscle only, those involving the central hamstring tendon have a worse prognosis. Limited information is available regarding the surgical treatment of central tendon injuries of the hamstrings. To describe the operative treatment and outcomes of central tendon injuries of the hamstrings among athletes. Case series; Level of evidence, 4. Eight athletes (6 top level, 2 recreational) with central hamstring tendon injuries underwent magnetic resonance imaging and surgical treatment. The indication for surgery was recurrent (n = 6) or acute (n = 2) central hamstring tendon injury. All patients followed the same postoperative rehabilitation protocol, and return to play was monitored. Magnetic resonance imaging found a central tendon injury in all 3 hamstring muscles (long head of the biceps femoris, semimembranosus, and semitendinosus) with disrupted tendon ends. In acute and recurrent central tendon injuries, full return to play was achieved at 2.5 to 4 months. There were no adverse events during follow-up. Central tendon injuries of the hamstrings can be successfully repaired surgically after acute and recurrent ruptures.

  7. Central Tendon Injuries of Hamstring Muscles: Case Series of Operative Treatment

    Science.gov (United States)

    Lempainen, Lasse; Kosola, Jussi; Pruna, Ricard; Puigdellivol, Jordi; Sarimo, Janne; Niemi, Pekka; Orava, Sakari

    2018-01-01

    Background: As compared with injuries involving muscle only, those involving the central hamstring tendon have a worse prognosis. Limited information is available regarding the surgical treatment of central tendon injuries of the hamstrings. Purpose: To describe the operative treatment and outcomes of central tendon injuries of the hamstrings among athletes. Study Design: Case series; Level of evidence, 4. Methods: Eight athletes (6 top level, 2 recreational) with central hamstring tendon injuries underwent magnetic resonance imaging and surgical treatment. The indication for surgery was recurrent (n = 6) or acute (n = 2) central hamstring tendon injury. All patients followed the same postoperative rehabilitation protocol, and return to play was monitored. Results: Magnetic resonance imaging found a central tendon injury in all 3 hamstring muscles (long head of the biceps femoris, semimembranosus, and semitendinosus) with disrupted tendon ends. In acute and recurrent central tendon injuries, full return to play was achieved at 2.5 to 4 months. There were no adverse events during follow-up. Conclusion: Central tendon injuries of the hamstrings can be successfully repaired surgically after acute and recurrent ruptures. PMID:29479545

  8. Tendon Transfer Surgery

    Science.gov (United States)

    ... All Topics A-Z Videos Infographics Symptom Picker Anatomy Bones Joints Muscles Nerves Vessels Tendons About Hand Surgery What is ... Hand Therapist? Media Find a Hand Surgeon Home Anatomy ... DESCRIPTION The tendon is the strong cord at either end of a muscle that is attached to bone. Tendons , combined with ...

  9. Tendon surveillance requirements - average tendon force

    International Nuclear Information System (INIS)

    Fulton, J.F.

    1982-01-01

    Proposed Rev. 3 to USNRC Reg. Guide 1.35 discusses the need for comparing, for individual tendons, the measured and predicted lift-off forces. Such a comparison is intended to detect any abnormal tendon force loss which might occur. Recognizing that there are uncertainties in the prediction of tendon losses, proposed Guide 1.35.1 has allowed specific tolerances on the fundamental losses. Thus, the lift-off force acceptance criteria for individual tendons appearing in Reg. Guide 1.35, Proposed Rev. 3, is stated relative to a lower bound predicted tendon force, which is obtained using the 'plus' tolerances on the fundamental losses. There is an additional acceptance criterion for the lift-off forces which is not specifically addressed in these two Reg. Guides; however, it is included in a proposed Subsection IWX to ASME Code Section XI. This criterion is based on the overriding requirement that the magnitude of prestress in the containment structure be sufficeint to meet the minimum prestress design requirements. This design requirement can be expressed as an average tendon force for each group of vertical hoop, or dome tendons. For the purpose of comparing the actual tendon forces with the required average tendon force, the lift-off forces measured for a sample of tendons within each group can be averaged to construct the average force for the entire group. However, the individual lift-off forces must be 'corrected' (normalized) prior to obtaining the sample average. This paper derives the correction factor to be used for this purpose. (orig./RW)

  10. Ultrasound of the elbow with emphasis on detailed assessment of ligaments, tendons, and nerves

    International Nuclear Information System (INIS)

    De Maeseneer, Michel; Brigido, Monica Kalume; Antic, Marijana; Lenchik, Leon; Milants, Annemieke; Vereecke, Evie; Jager, Tjeerd; Shahabpour, Maryam

    2015-01-01

    Highlights: •Medial and lateral tendons: the different muscles forming these tendons can be followed up to the insertion. The imaging anatomy is reviewed. •Medial and lateral ligaments: the anatomy is complex and specialized imaging planes and arm positions are necessary for accurate assessment. •Biceps tendon: the anatomy of the distal biceps and lacertus fibrosus are discussed and illustrated with cadaveric correlation. •US imaging of the nerves about the elbow and visualization of the possible compression points is discussed. -- Abstract: The high resolution and dynamic capability of ultrasound make it an excellent tool for assessment of superficial structures. The ligaments, tendons, and nerves about the elbow can be fully evaluated with ultrasound. The medial collateral ligament consists of an anterior and posterior band that can easily be identified. The lateral ligament complex consists of the radial collateral ligament, ulnar insertion of the annular ligament, and lateral ulnar collateral ligament, easily identified with specialized probe positioning. The lateral ulnar collateral ligament can best be seen in the cobra position. On ultrasound medial elbow tendons can be followed nearly up to their common insertion. The pronator teres, flexor carpi radialis, palmaris longus, and flexor digitorum superficialis can be identified. The laterally located brachioradialis and extensor carpi radialis longus insert on the supracondylar ridge. The other lateral tendons can be followed up to their common insertion on the lateral epicondyle. The extensor digitorum, extensor carpi radialis brevis, extensor digiti minimi, and extensor carpi ulnaris can be differentiated. The distal biceps tendon is commonly bifid. For a complete assessment of the distal biceps tendon specialized views are necessary. These include an anterior axial approach, medial and lateral approach, and cobra position. In the cubital tunnel the ulnar nerve is covered by the ligament of Osborne

  11. Ultrasound of the elbow with emphasis on detailed assessment of ligaments, tendons, and nerves

    Energy Technology Data Exchange (ETDEWEB)

    De Maeseneer, Michel, E-mail: Michel.demaeseneer@uzbrussel.be [Department of Radiology, Universitair Ziekenhuis Brussel, Brussels (Belgium); Brigido, Monica Kalume, E-mail: Mbrigido@med.umich.edu [Department of Radiology, University of Michigan, Ann Arbor, MI (United States); Antic, Marijana, E-mail: Misscroa@gmail.com [Department of Radiology, Universitair Ziekenhuis Brussel, Brussels (Belgium); Lenchik, Leon, E-mail: Llenchik@wakehealth.edu [Department of Radiology, Wake Forest University, Winston-Salem, NC (United States); Milants, Annemieke, E-mail: Annemieke.Milants@gmail.com [Department of Radiology, Universitair Ziekenhuis Brussel, Brussels (Belgium); Vereecke, Evie, E-mail: Evie.Vereecke@kuleuven-kulak.be [Department of Anatomy, KULAK, Katholieke Universiteit Leuven, Campus Kortrijk, Kortrijk (Belgium); Jager, Tjeerd [Aalsters Stedelijk Ziekenhuis, Aalst (Belgium); Shahabpour, Maryam, E-mail: Maryam.Shahabpour@uzbrussel.be [Department of Radiology, Universitair Ziekenhuis Brussel, Brussels (Belgium)

    2015-04-15

    Highlights: •Medial and lateral tendons: the different muscles forming these tendons can be followed up to the insertion. The imaging anatomy is reviewed. •Medial and lateral ligaments: the anatomy is complex and specialized imaging planes and arm positions are necessary for accurate assessment. •Biceps tendon: the anatomy of the distal biceps and lacertus fibrosus are discussed and illustrated with cadaveric correlation. •US imaging of the nerves about the elbow and visualization of the possible compression points is discussed. -- Abstract: The high resolution and dynamic capability of ultrasound make it an excellent tool for assessment of superficial structures. The ligaments, tendons, and nerves about the elbow can be fully evaluated with ultrasound. The medial collateral ligament consists of an anterior and posterior band that can easily be identified. The lateral ligament complex consists of the radial collateral ligament, ulnar insertion of the annular ligament, and lateral ulnar collateral ligament, easily identified with specialized probe positioning. The lateral ulnar collateral ligament can best be seen in the cobra position. On ultrasound medial elbow tendons can be followed nearly up to their common insertion. The pronator teres, flexor carpi radialis, palmaris longus, and flexor digitorum superficialis can be identified. The laterally located brachioradialis and extensor carpi radialis longus insert on the supracondylar ridge. The other lateral tendons can be followed up to their common insertion on the lateral epicondyle. The extensor digitorum, extensor carpi radialis brevis, extensor digiti minimi, and extensor carpi ulnaris can be differentiated. The distal biceps tendon is commonly bifid. For a complete assessment of the distal biceps tendon specialized views are necessary. These include an anterior axial approach, medial and lateral approach, and cobra position. In the cubital tunnel the ulnar nerve is covered by the ligament of Osborne

  12. FIBRILLINS IN TENDON

    Directory of Open Access Journals (Sweden)

    Betti Giusti

    2016-10-01

    Full Text Available Tendons among connective tissue, mainly collagen, contain also elastic fibres made of fibrillin 1, fibrillin 2 and elastin that are broadly distributed in tendons and represent 1-2% of the dried mass of the tendon. Only in the last years, studies on structure and function of elastic fibres in tendons have been performed. Aim of this review is to revise data on the organization of elastic fibres in tendons, in particular fibrillin structure and function, and on the clinical manifestations associated to alterations of elastic fibres in tendons. Indeed, microfibrils may contribute to tendon mechanics; therefore, their alterations may cause joint hypermobility and contractures which have been found to be clinical features in patients with Marfan syndrome and Beals syndrome. The two diseases are caused by mutations in genes FBN1 and FBN2 encoding fibrillin 1 and fibrillin 2, respectively.

  13. The 'bridging sign', a MR finding for combined full-thickness tears of the subscapularis tendon and the supraspinatus tendon

    International Nuclear Information System (INIS)

    Jung, Jin Young; Yoon, Young Cheol; Cha, Dong Ik; Yoo, Jae-Chul; Jung, Jee Young

    2013-01-01

    Background: In daily practice, we discovered one of the secondary magnetic resonance (MR) findings of the subscapularis (SSC) tendon tear, the 'bridging sign', which has not been previously described. Purpose: To describe the 'bridging sign' on shoulder MR imaging and its radiological and clinical significance in patients with SSC tendon tear. Material and Methods: Twenty-nine patients who had undergone shoulder arthroscopy and had full-thickness tear of the subscapularis tendon were enrolled. The medical records of the 29 patients were retrospectively reviewed for the duration of shoulder pain, rotator cuff tears, and associated arthroscopic findings: biceps tendon abnormality and superior glenoid labral tear. Then, preoperative shoulder MR images were retrospectively reviewed for the presence or absence of the 'bridging sign' and associated MR findings: periarticular fluid and fatty atrophy of the supraspinatus and subscapularis muscles. The type of rotator cuff tear associated with the 'bridging sign' was assessed and the sensitivity, specificity, and accuracy of the 'bridging sign' for the diagnosis of a certain type of rotator cuff tear were calculated. Associated arthroscopic and MR findings and mean duration of the shoulder pain between the patients with and without the 'bridging sign' were compared. Results: The 'bridging sign' was seen in 17 of 29 patients and corresponded to a complex of the torn and superomedially retracted subscapularis tendon, coracohumeral ligament, and superior glenohumeral ligament, adhered to the anterior margin of the torn supraspinatus (SSP) tendon on arthroscopy. All patients with the 'bridging sign' had combined full-thickness tear (FTT) of the cranial 1/2 portion of the subscapularis tendon and anterior 1/2 portion of the SSP tendon. The sensitivity, specificity, and accuracy of the 'bridging sign' for the diagnosis of combined FTTs of the SSC tendon and anterior portion of the SSP tendon were 81.0%, 100%, and 86

  14. Prolonged passive static stretching-induced innervation zone shift in biceps brachii.

    Science.gov (United States)

    Ye, Xin; Beck, Travis W; Wages, Nathan P

    2015-05-01

    The purpose of this study was to examine the influence of a bout of repeated and prolonged passive static stretching on the innervation zone (IZ) location of the human biceps brachii muscle. Eleven men performed 12 sets of 100-s passive stretches on their biceps brachii. Before (Pre) and immediately after (Post) the stretching intervention, isometric strength was tested during the maximal voluntary contractions (MVCs) of the forearm flexors. The subjects also performed several separate isometric forearm flexion muscle actions at 30%, 50%, and 70% of their predetermined MVCs for examining the locations of the IZ at different contraction intensities. The IZ was identified through multi-channel surface electromyographic (EMG) recordings from a linear electrode array. The stretching intervention induced an average of 10% isometric strength loss for the forearm flexors (mean±SD: Pre-MVC vs. Post-MVC=332.12±59.40 N vs. 299.53±70.51 N; p<0.001). In addition, the average IZ shift was nearly 4.5 mm in average in the proximal direction. However, this shift was not specific to the contraction intensity. We believe that the IZ shift was caused by the elongation of the entire muscle-tendon unit in the proximal direction. Therefore, caution should be taken when using surface EMG technique to examine possible changes in the EMG variables after a stretching protocol, as these variables can be contaminated by the shift of the IZ.

  15. The MR arthrographic anatomy of the biceps labral insertion and its morphological significance with labral tears in patients with shoulder instability

    International Nuclear Information System (INIS)

    Jakanani, G.C.; Botchu, R.; Rennie, W.J.

    2012-01-01

    Introduction: Most of the fibres of the long head of biceps tendon attach on the superior labrum just posterior to the supraglenoid tubercle. Aim: Our hypothesis was that posteriorly attached biceps tendons predispose to posterior superior labral tears and SLAP lesions. Methods and materials: A prospective analysis of all MR shoulder arthrograms for shoulder instability referred from the shoulder specialist clinics, performed during a one year period were reviewed by two independent observers who were blinded to clinical history. The biceps attachment was classified into four groups according to the method described in an earlier cadaveric study into four groups; posterior-type 1, predominantly posterior-type 2, equal contributions to both anterior and posterior labrum-type 3 and predominantly anterior labral attachment-type 4. Data was analysed using Kappa statistics and Fischer's exact test. Results: 48 patients (33 males and 15 females) were included in this study with a mean age of 32 years. Majority, 22 patients (46%) had a type 1 attachment of the biceps on the superior labrum. There was moderate intra-observer and good interobserver agreement with a Kappa of 0.58 and 0.63 respectively. There was a significant association between a type 2 attachment and posterior tears (p ≤ 0.04) and also between a type 2 attachment and SLAP tears (p ≤ 0.04). Conclusion: Our results suggest that variation in anatomy of biceps origin influences the type of labral tears that occur in patients with shoulder instability. The importance of these findings could influence selection of individuals in throwing sports like cricket and baseball.

  16. The MR arthrographic anatomy of the biceps labral insertion and its morphological significance with labral tears in patients with shoulder instability

    Energy Technology Data Exchange (ETDEWEB)

    Jakanani, G.C., E-mail: gcjakanani@gmail.com [Leicester Royal Infirmary, Leicester (United Kingdom); Botchu, R., E-mail: drrajeshb@gmail.com [Leicester Royal Infirmary, Leicester (United Kingdom); Rennie, W.J., E-mail: winston.rennie@gmail.com [Leicester Royal Infirmary, Leicester (United Kingdom)

    2012-11-15

    Introduction: Most of the fibres of the long head of biceps tendon attach on the superior labrum just posterior to the supraglenoid tubercle. Aim: Our hypothesis was that posteriorly attached biceps tendons predispose to posterior superior labral tears and SLAP lesions. Methods and materials: A prospective analysis of all MR shoulder arthrograms for shoulder instability referred from the shoulder specialist clinics, performed during a one year period were reviewed by two independent observers who were blinded to clinical history. The biceps attachment was classified into four groups according to the method described in an earlier cadaveric study into four groups; posterior-type 1, predominantly posterior-type 2, equal contributions to both anterior and posterior labrum-type 3 and predominantly anterior labral attachment-type 4. Data was analysed using Kappa statistics and Fischer's exact test. Results: 48 patients (33 males and 15 females) were included in this study with a mean age of 32 years. Majority, 22 patients (46%) had a type 1 attachment of the biceps on the superior labrum. There was moderate intra-observer and good interobserver agreement with a Kappa of 0.58 and 0.63 respectively. There was a significant association between a type 2 attachment and posterior tears (p {<=} 0.04) and also between a type 2 attachment and SLAP tears (p {<=} 0.04). Conclusion: Our results suggest that variation in anatomy of biceps origin influences the type of labral tears that occur in patients with shoulder instability. The importance of these findings could influence selection of individuals in throwing sports like cricket and baseball.

  17. Stability of the plasma sheath

    International Nuclear Information System (INIS)

    Franklin, R.N.

    1979-12-01

    The stability of a collisionless sheath joined to a plasma in the presence of secondary emission of electrons from the sheath boundary is examined in the fluid approximation. Instability is unlikely to occur under floating conditions but if significant currents flow corresponding to increased wall-plasma potentials the system can go unstable. (author)

  18. Achilles tendon and sports

    International Nuclear Information System (INIS)

    Ulreich, N.; Kainberger, F.; Huber, W.; Nehrer, S.

    2002-01-01

    Because of the rising popularity of recreational sports activities achillodynia is an often associated symptom with running, soccer and athletics. Therefore radiologist are frequently asked to image this tendon. The origin of the damage of the Achilles tendon is explained by numerous hypothesis, mainly a decreased perfusion and a mechanical irritation that lead to degeneration of the tendon. High-resolution technics such as sonography and magnetic resonance imaging show alterations in the structure of the tendon which can be graduated and classified. Manifestations like tendinosis, achillobursitis, rupture and Haglunds disease can summarized as the tendon overuse syndrom. A rupture of a tendon is mostly the result of a degeneration of the collagenfibres. The task of the radiologist is to acquire the intrinsic factors for a potential rupture. (orig.) [de

  19. Effect of patient age on accuracy of primary MRI signs of long head of biceps tearing and instability in the shoulder. An MRI-arthroscopy correlation study

    Energy Technology Data Exchange (ETDEWEB)

    Borrero, Camilo G.; Costello, Joanna; Vyas, Dharmesh [University of Pittsburgh Medical Center, Pittsburgh, PA (United States); Bertolet, Marnie [University of Pittsburgh School of Medicine, Pittsburgh, PA (United States)

    2018-02-15

    To determine the effect of patient age on the accuracy of primary MRI signs of long head of biceps (LHB) tendon tearing and instability in the shoulder using arthroscopy as a reference standard. Subjects with MRI studies and subsequent arthroscopy documenting LHB tendon pathology were identified and organized into three age groups (18-40, 41-60, 61-87). Normal and tendinopathic tendons were labeled grade 0, partial tears grade 1 and full tears grade 2. Two radiologists blinded to arthroscopic data graded MRI studies independently. Prevalence of disease, MRI accuracy for outcomes of interest, and inter-reader agreement were calculated. Eighty-nine subjects fulfilled inclusion criteria with 36 grade 0, 36 grade 1 and 17 grade 2 tendons found at arthroscopy. MRI sensitivity, regardless of age, ranged between 67-86% for grade 0, 72-94% for grade 1 and 82-94% for grade 2 tendons. Specificity ranged between 83-96% for grade 0, 75-85% for grade 1 and 99-100% for grade 2 tendons. MRI accuracy for detection of each LHB category was calculated for each age group. MRI was found to be least sensitive for grade 0 and 1 LHB tendons in the middle-aged group with sensitivity between 55-85% for grade 0 and 53-88% for grade 1 tendons. Agreement between MRI readers was moderate with an unweighted kappa statistic of 62%. MRI accuracy was moderate to excellent and agreement between MRI readers was moderate. MRI appears to be less accurate in characterizing lower grades of LHB tendon disease in middle-aged subjects. (orig.)

  20. Segond fracture: involvement of the iliotibial band, anterolateral ligament, and anterior arm of the biceps femoris in knee trauma

    Energy Technology Data Exchange (ETDEWEB)

    Maeseneer, Michel de; Boulet, Cedric; Willekens, Inneke; Mey, Johan de; Shahabpour, Maryam [Universitair Ziekenhuis Brussel, Department of Radiology, Brussels (Belgium); Lenchik, Leon [Wake Forest University, Department of Radiology, Winston Salem, NC (United States); Cattrysse, Erik [Vrije Universiteit Brussel, Department of Experimental Anatomy, Brussels (Belgium)

    2014-12-04

    To evaluate the involvement of the iliotibial band (ITB), the anterolateral ligament (ALL), and the anterior arm of the biceps femoris in MRI-diagnosed Segond fracture and to evaluate other associated findings of Segond fracture. We retrospectively reviewed the MRI of 13 cases of Segond fracture. The studies included proton density-weighted, T2-weighted, and proton density-weighted with fat saturation images in the three planes. We studied 2 cadaveric specimens with emphasis on the ALL. One cadaveric specimen was dissected while the other was sectioned in the sagittal plane. The mean age of the patients was 36 years (range, 17-52). There were 7 men and 6 women. The mean size of the Segond bone fragment was 8 x 10 x 2 mm. The distance from the tibia varied from 2 to 6 mm. Associated findings included anterior cruciate ligament (ACL) tear (n = 13), medial collateral ligament (MCL) tear (n = 8), meniscocapsular tear of the posterior horn of the medial meniscus (n = 5), and posterolateral corner involvement (n = 4). Bone marrow edema involved the mid-lateral femoral condyle and the posterior tibial plateau on both the medial and the lateral side. Edema at the Segond area was seen, but was limited. Fibular head edema was also seen. The ITB (11 out of 13) and ALL (10 out of 13) inserted on the Segond bone fragment. The anterior arm of the biceps tendon did not insert on the Segond fracture. Associated findings of Segond fracture include ACL tear, MCL tear, medial meniscus tear, and posterolateral corner injury. Both the ITB and the ALL may be involved in the Segond avulsion. The anterior arm of the biceps femoris tendon is not involved. (orig.)

  1. Segond fracture: involvement of the iliotibial band, anterolateral ligament, and anterior arm of the biceps femoris in knee trauma

    International Nuclear Information System (INIS)

    Maeseneer, Michel de; Boulet, Cedric; Willekens, Inneke; Mey, Johan de; Shahabpour, Maryam; Lenchik, Leon; Cattrysse, Erik

    2015-01-01

    To evaluate the involvement of the iliotibial band (ITB), the anterolateral ligament (ALL), and the anterior arm of the biceps femoris in MRI-diagnosed Segond fracture and to evaluate other associated findings of Segond fracture. We retrospectively reviewed the MRI of 13 cases of Segond fracture. The studies included proton density-weighted, T2-weighted, and proton density-weighted with fat saturation images in the three planes. We studied 2 cadaveric specimens with emphasis on the ALL. One cadaveric specimen was dissected while the other was sectioned in the sagittal plane. The mean age of the patients was 36 years (range, 17-52). There were 7 men and 6 women. The mean size of the Segond bone fragment was 8 x 10 x 2 mm. The distance from the tibia varied from 2 to 6 mm. Associated findings included anterior cruciate ligament (ACL) tear (n = 13), medial collateral ligament (MCL) tear (n = 8), meniscocapsular tear of the posterior horn of the medial meniscus (n = 5), and posterolateral corner involvement (n = 4). Bone marrow edema involved the mid-lateral femoral condyle and the posterior tibial plateau on both the medial and the lateral side. Edema at the Segond area was seen, but was limited. Fibular head edema was also seen. The ITB (11 out of 13) and ALL (10 out of 13) inserted on the Segond bone fragment. The anterior arm of the biceps tendon did not insert on the Segond fracture. Associated findings of Segond fracture include ACL tear, MCL tear, medial meniscus tear, and posterolateral corner injury. Both the ITB and the ALL may be involved in the Segond avulsion. The anterior arm of the biceps femoris tendon is not involved. (orig.)

  2. Testing hybrid natural inflation with BICEP2

    Energy Technology Data Exchange (ETDEWEB)

    Carrillo-González, Mariana [Instituto de Ciencias Físicas, Universidad Nacional Autónoma de México, Apdo. Postal 48-3, 62251 Cuernavaca, Morelos (Mexico); Germán, Gabriel, E-mail: gabriel@fis.unam.mx [Instituto de Ciencias Físicas, Universidad Nacional Autónoma de México, Apdo. Postal 48-3, 62251 Cuernavaca, Morelos (Mexico); Herrera-Aguilar, Alfredo [Departamento de Física, Universidad Autónoma Metropolitana Iztapalapa, San Rafael Atlixco 186, CP 09340, México D.F. (Mexico); Instituto de Física y Matemáticas, Universidad Michoacana de San Nicolás de Hidalgo, Edificio C-3, Ciudad Universitaria, CP 58040, Morelia, Michoacán (Mexico); Hidalgo, Juan Carlos [Instituto de Ciencias Físicas, Universidad Nacional Autónoma de México, Apdo. Postal 48-3, 62251 Cuernavaca, Morelos (Mexico); Sussman, Roberto A. [Instituto de Ciencias Nucleares, Universidad Nacional Autónoma de México, Apdo. Postal 70-543, 04510 México D.F. (Mexico)

    2014-06-27

    We analyse Hybrid Natural Inflation in view of the recent results for the tensor index reported by BICEP2. We find that it predicts a large running of the scalar spectrum which is potentially detectable by large scale structure through measurements of clustering of galaxies in combination with CMB data and by 21 cm forest observations. The running of the running is also relatively large becoming close to 10{sup −2}. Along the way, we find general consistency relations at which observables are subject if the slow-roll approximation is imposed. Failure to satisfy these equations by the values obtained for the observables in surveys would be a failure of the slow-roll approximation itself.

  3. [Bursitis with severe tendon and muscle necrosis on the lateral stifle area in cattle].

    Science.gov (United States)

    Nuss, K; Räber, M; Sydler, T; Muggli, E; Hässig, M; Guscetti, F

    2011-11-01

    In 21 animals, chronic swelling on the lateral aspect of the stifle also known as «perigonitis», «stable-syndrome» or «bursitis bicipitalis femoris» were evaluated. Ultrasonography showed increased fluid in the distal subtendinous bursa of the biceps femoris muscle and structural changes in the tendons, muscles, subcutis and fasciae. Soft tissue swelling and an irregular contour of the lateral tibial condyle were typical signs on radiographs. Macroscopic changes were found at the insertion of the biceps femoris muscle, the distal subtendinous bursa of the biceps femoris muscle, the lateral collateral ligament of the stifle, the origin of muscles on the lateral femoral condyle and the lateral tibial condyle. They mainly consisted of tendon and muscle tissue necrosis with granulation tissue. Histology revealed areas of coagulation necrosis in tendons and ligaments, in which occasionally Onchocerca spp. were seen. The severity of lesions correlated well with the clinical signs, which were associated with a poor prognosis in advanced cases.

  4. Containment structure tendon investigation

    International Nuclear Information System (INIS)

    Fulton, J.F.; Murray, K.H.

    1983-01-01

    The paper describes an investigation into the possible causes of lower-than-predicted tendon forces which were measured during past tendon surveillances for a concrete containment. The containment is post tensioned by vertical tendons which are anchored into a rock foundation. The tendons were originally stressed in 1969, and lift-off tests were performed on six occasions subsequent to this date over a period of 11 years. The tendon forces measured in these tests were generally lower than predicted, and by 1979 the prestress level in the containment was only marginally above the design requirement. The tendons were retensioned in 1980, and by this time an investigation into the possible causes was underway. Potential causes investigated include the rock anchors and surrounding rock, elastomeric pad creep, wire stresses, thermal effects, stressing equipment and lift-off procedures, and wire stress relaxation. The investigation activities included stress relaxation testing of wires pulled from actual tendons. The stress relaxation test program included wire specimens at several different temperature and initial stress levels and the effect of a varying temperature history on the stress relaxation property of the wires. For purpose of future force predictions of the retensioned tendons, the test program included tests to determine the effect on stress relaxation due to restressing the wires after they had relaxed for 1000 hours and 10,000 hours. (orig./GL)

  5. Extensor Tendon Injuries

    Science.gov (United States)

    ... All Topics A-Z Videos Infographics Symptom Picker Anatomy Bones Joints Muscles Nerves Vessels Tendons About Hand Surgery What is a Hand Surgeon? What is a Hand Therapist? Media Find a Hand Surgeon Home Anatomy Extensor Tendon Injuries Email to a friend * required ...

  6. The frondiform ligament and pseudotenosynovitis of the extensor digitorum longus tendon: MRI evaluation with cadaveric correlation

    International Nuclear Information System (INIS)

    Zember, Jonathan; Rosenberg, Zehava; Mba-Jones, Chimere; Bencardino, Jenny; Rossi, Ignacio

    2016-01-01

    Fluid along the frondiform ligament, the sinus tarsi stem of the inferior extensor retinaculum (IER), can approximate the extensor digitorum longus (EDL), at times simulating tenosynovitis. Our purpose, based on MRI and cadaveric studies, was to further evaluate this scantly described phenomenon, to identify associated findings and to alert the radiologists to the potential pitfall of over diagnosing EDL tenosynovitis. Two musculoskeletal radiologists retrospectively reviewed the radiology reports and MRI studies of 258 ankle MRI exams, performed at our institution, for fluid along the frondiform ligament extending toward the EDL. No patient had EDL pathology clinically. MRI was performed in two cadaveric ankles following injection of the sinus tarsi and EDL tendon sheath, under ultrasound guidance. Altogether, 31 MRIs demonstrated fluid extending from the sinus tarsi along the frondiform ligament toward the EDL. In 30 cases (97 %), the fluid partially surrounded the tendon, without tendon sheath distension. Based on the radiology reports, in 11 of the 31 cases (35 %), the fluid was misinterpreted as abnormal. Most common associated findings included ligamentous injury, posterior tibial tendon (PTT) tear, flat-foot, and osteoarthrosis. In the cadavers, fluid extended along the frondiform ligament toward the EDL after sinus tarsi injection; there was no communication between EDL tendon sheath and the sinus tarsi. Fluid within the sinus tarsi can extend along the frondiform ligament and partially surround the EDL, manifesting as pseudotenosynovitis. This phenomenon, often seen with ligamentous tears or PTT dysfunction, should not be misdiagnosed as true pathology of the EDL. (orig.)

  7. Sex Hormones and Tendon

    DEFF Research Database (Denmark)

    Hansen, Mette; Kjaer, Michael

    2016-01-01

    The risk of overuse and traumatic tendon and ligament injuries differ between women and men. Part of this gender difference in injury risk is probably explained by sex hormonal differences which are specifically distinct during the sexual maturation in the teenage years and during young adulthood....... The effects of the separate sex hormones are not fully elucidated. However, in women, the presence of estrogen in contrast to very low estrogen levels may be beneficial during regular loading of the tissue or during recovering after an injury, as estrogen can enhance tendon collagen synthesis rate. Yet...... has also been linked to a reduced responsiveness to relaxin. The present chapter will focus on sex difference in tendon injury risk, tendon morphology and tendon collagen turnover, but also on the specific effects of estrogen and androgens....

  8. MRI study of associated shoulder pathology in patients with full-thickness subscapularis tendon tears.

    Science.gov (United States)

    Li, Xinning; Fallon, Jonathan; Egge, Natalie; Curry, Emily J; Patel, Ketan; Owens, Brett D; Busconi, Brian D

    2013-01-01

    Subscapularis tendon tears are a well-established cause of shoulder pain. The objective of the current study was to evaluate the associated shoulder pathology in patients with full-thickness subscapularis tendon tears using magnetic resonance imaging. Forty-seven magnetic resonance imaging studies taken between 2008 and 2009 with a diagnosis of full-thickness subscapularis tendon tears were reviewed. The size of the subscapularis tendon tear, amount of muscle volume loss, Goutallier grade, biceps tendon pathology, coracohumeral distance, and associated rotator cuff tears were recorded. Statistical analysis was performed. Patients 55 years and older vs those 54 years and younger had an average subscapularis tear size of 35 vs 19 mm, an average Goutallier grade of 2.7 vs 0.8, and a total muscle volume loss of 25% vs 5%, respectively. Patients with a dislocated vs normal biceps tendons had an average subscapularis tear size of 37 vs 23 mm, an average Goutallier grade of 3 vs 0.9, and a total muscle volume loss of 28% vs 7%, respectively. Patients with vs without concomitant rotator cuff tears had an average subscapularis tear size of 32 vs 17 mm, an average Goutallier grade of 2.3 vs 0.6, and a total muscle volume loss of 21% vs 3%, respectively. Overall average coracohumeral distance measured in the axial plane was 10.8±4.6 mm. Average coracaohumeral distance was 14.8 vs 8.1 mm in patients with a Goutallier grade of 0 vs 3 or 4, resepectively, and 13.6 vs 8.5 mm in patients with no rotator cuff tear vs those with a supra- and infraspinatus tear, respectively. Increased age, dislocated biceps tendons, and concomitant rotator cuff tears in patients with full-thickness subscapularis tendon tears are associated with larger subscapularis tendon tear size, higher Goutallier grades, and increased subscapularis muscle volume loss. Decreased coracohumeral distance is associated with a higher Goutallier grade and rotator cuff tears. Copyright 2013, SLACK Incorporated.

  9. The electrostatic cylindrical sheath in a plasma

    International Nuclear Information System (INIS)

    Wang Chunhua; Sun Xiaoxia; Bai Dongxue

    2004-01-01

    The electrostatic sheath with a cylindrical geometry in an ion-electron plasma is investigated. Assuming a Boltzmann response to electrons and cold ions with bulk flow, it is shown that the radius of the cylindrical geometry do not affect the sheath potential significantly. The authors also found that the sheath potential profile is steeper in the cylindrical sheath compared to the slab sheath. The distinct feature of the cylindrical sheath is that the ion density distribution is not monotonous. The sheath region can be divided into three regions, two ascendant regions and one descendant region. (author)

  10. Condition Assessment of PC Tendon Duct Filling by Elastic Wave Velocity Mapping

    Directory of Open Access Journals (Sweden)

    Kit Fook Liu

    2014-01-01

    Full Text Available Imaging techniques are high in demand for modern nondestructive evaluation of large-scale concrete structures. The travel-time tomography (TTT technique, which is based on the principle of mapping the change of propagation velocity of transient elastic waves in a measured object, has found increasing application for assessing in situ concrete structures. The primary aim of this technique is to detect defects that exist in a structure. The TTT technique can offer an effective means for assessing tendon duct filling of prestressed concrete (PC elements. This study is aimed at clarifying some of the issues pertaining to the reliability of the technique for this purpose, such as sensor arrangement, model, meshing, type of tendon sheath, thickness of sheath, and material type as well as the scale of inhomogeneity. The work involved 2D simulations of wave motions, signal processing to extract travel time of waves, and tomography reconstruction computation for velocity mapping of defect in tendon duct.

  11. Anode sheath in Hall thrusters

    International Nuclear Information System (INIS)

    Dorf, L.; Semenov, V.; Raitses, Y.

    2003-01-01

    A set of hydrodynamic equations is used to describe quasineutral plasma in ionization and acceleration regions of a Hall thruster. The electron distribution function and Poisson equation are invoked for description of a near-anode region. Numerical solutions suggest that steady-state operation of a Hall thruster can be achieved at different anode sheath regimes. It is shown that the anode sheath depends on the thruster operating conditions, namely the discharge voltage and the mass flow rate

  12. Gauged M-flation after BICEP2

    Science.gov (United States)

    Ashoorioon, A.; Sheikh-Jabbari, M. M.

    2014-12-01

    In view of the recent BICEP2 results [arxiv:arXiv:1403.3985] which may be attributed to the observation of B-modes polarization of the CMB with tensor-to-scalar ratio r =0.2-0.05+0.07, we revisit M-flation model. Gauged M-flation is a string theory motivated inflation model with Matrix valued scalar inflaton fields in the adjoint representation of a U (N) Yang-Mills theory. In continuation of our previous works, we show that for a class of M-flation models the action for these inflaton fields can be such that the "effective inflaton field" ϕ has a double-well Higgs-like potential, with minima at ϕ = 0 , μ. We focus on the ϕ > μ, symmetry-breaking region. We thoroughly examine predictions of the model for r in the 2σ region allowed for nS by the Planck experiment. As computed in [arxiv:arXiv:0903.1481], for Ne = 60 and nS = 0.96 we find r ≃ 0.2, which sits in the sweet spot of BICEP2 region for r. We find that with increasing μ arbitrarily, nS cannot go beyond ≃0.9670, the scalar spectral index for the quadratic chaotic potential. As nS varies in the 2σ range which is allowed by Planck and could be reached by the model, r varies in the range [ 0.13 , 0.26 ]. Future cosmological experiments, like the CMBPOL, that confines nS with σ (nS) = 0.0029 can constrain the model further. Also, in this region of potential, for nS = 0.9603, we find that the largest isocurvature mode, which is uncorrelated with curvature perturbations, has a power spectrum with the amplitude of order 10-11 at the end of inflation. We also discuss the range of predictions of r in the hilltop region, ϕ < μ.

  13. Gauged M-flation after BICEP2

    International Nuclear Information System (INIS)

    Ashoorioon, A.; Sheikh-Jabbari, M.M.

    2014-01-01

    In view of the recent BICEP2 results [ (arXiv:1403.3985)] which may be attributed to the observation of B-modes polarization of the CMB with tensor-to-scalar ratio r=0.2 −0.05 +0.07 , we revisit M-flation model. Gauged M-flation is a string theory motivated inflation model with Matrix valued scalar inflaton fields in the adjoint representation of a U(N) Yang–Mills theory. In continuation of our previous works, we show that for a class of M-flation models the action for these inflaton fields can be such that the “effective inflaton field” ϕ has a double-well Higgs-like potential, with minima at ϕ=0,μ. We focus on the ϕ>μ, symmetry-breaking region. We thoroughly examine predictions of the model for r in the 2σ region allowed for n S by the Planck experiment. As computed in [ (arXiv:0903.1481)], for N e =60 and n S =0.96 we find r≃0.2, which sits in the sweet spot of BICEP2 region for r. We find that with increasing μ arbitrarily, n S cannot go beyond ≃0.9670, the scalar spectral index for the quadratic chaotic potential. As n S varies in the 2σ range which is allowed by Planck and could be reached by the model, r varies in the range [0.13,0.26]. Future cosmological experiments, like the CMBPOL, that confines n S with σ(n S )=0.0029 can constrain the model further. Also, in this region of potential, for n S =0.9603, we find that the largest isocurvature mode, which is uncorrelated with curvature perturbations, has a power spectrum with the amplitude of order 10 −11 at the end of inflation. We also discuss the range of predictions of r in the hilltop region, ϕ<μ

  14. S-dual inflation: BICEP2 data without unlikeliness

    International Nuclear Information System (INIS)

    Anchordoqui, Luis A.; Barger, Vernon; Goldberg, Haim; Huang, Xing; Marfatia, Danny

    2014-01-01

    We show that S-dual inflationary potentials solve the unlikeliness problem manifested in Planck data and explain the excess B-mode power observed by the BICEP2 experiment as arising from primordial tensor fluctuations

  15. Tendon 'turnover lengthening' technique.

    Science.gov (United States)

    Cerovac, S; Miranda, B H

    2013-11-01

    Tendon defect reconstruction is amongst the most technically challenging areas in hand surgery. Tendon substance deficiency reconstruction techniques include lengthening, grafting, two-stage reconstruction and tendon transfers, however each is associated with unique challenges over and above direct repair. We describe a novel 'turnover lengthening' technique for hand tendons that has successfully been applied to the repair of several cases, including a case of attritional flexor and traumatic extensor tendon rupture in two presented patients where primary tenorrhaphy was not possible. In both cases a good post-operative outcome was achieved, as the patients were happy having returned back to normal activities of daily living such that they were discharged 12 weeks post-operatively. Our technique avoids the additional morbidity and complications associated with grafting, transfers and two stage reconstructions. It is quick, simple and reproducible for defects not exceeding 3-4 cm, provides a means of immediate one stage reconstruction, no secondary donor site morbidity and does not compromise salvage by tendon transfer and/or two-stage reconstruction in cases of failure. To our knowledge no such technique has been previously been described to reconstruct such hand tendon defects. Crown Copyright © 2013. Published by Elsevier Ltd. All rights reserved.

  16. MR imaging of delamination tears of the rotator cuff tendons

    International Nuclear Information System (INIS)

    Walz, Daniel M.; Chen, Steven; Miller, Theodore T.; Hofman, Josh

    2007-01-01

    The objective was to describe the imaging appearances and location of delamination tears of the rotator cuff tendons on non-contrast conventional MR imaging. This study was reviewed and approved by our Institutional Review Board. The reports of 548 consecutive MR examinations of the shoulder were reviewed, looking for mention or description of delamination tears of the rotator cuff. The images of the identified cases were then reviewed by two radiologists to confirm the findings. Correlation with surgical and arthroscopic information was then performed. Delamination tears were defined as horizontal retraction of either the bursal or articular surface of the tendon, manifest as thickening of the torn retracted edge, and/or interstitial splitting of the tendon, manifest as fluid-like high signal intensity on fat-suppressed T2-weighted oblique coronal images. Fourteen cases of delamination tears were identified in 13 patients. Ten of the cases involved the supraspinatus tendon, all with articular surface involvement. Nine of these supraspinatus cases were isolated tears and one occurred as part of a full thickness tear. All 10 of these supraspinatus cases showed medial retraction of the articular surface of the tendon, with thickening of the retracted edge, and 5 of the 10 had a demonstrable horizontal cleft in the interstitium. Four cases involved the subscapularis tendon, with articular surface disruption in three and pure interstitial delamination in one. Medial subluxation of the tendon of the long head of the biceps was present in all four cases. No delamination tears occurred on the bursal surface. Only three of the 14 shoulders underwent surgical repair with one confirmation of supraspinatus delamination, one confirmation of a subscapularis tear that had become a full thickness tear 10 months after initial imaging and another interstitial subscapularis delamination that was not identified arthroscopically. Delamination tears occur most often in the

  17. MR imaging of delamination tears of the rotator cuff tendons

    Energy Technology Data Exchange (ETDEWEB)

    Walz, Daniel M.; Chen, Steven [North Shore University Hospital, Department of Radiology, Manhasset, NY (United States); Miller, Theodore T. [Hospital for Special Surgery, Department of Radiology and Imaging, New York, NY (United States); Hofman, Josh [Long Island Jewish Medical Center, New Hyde Park, NY (United States)

    2007-05-15

    The objective was to describe the imaging appearances and location of delamination tears of the rotator cuff tendons on non-contrast conventional MR imaging. This study was reviewed and approved by our Institutional Review Board. The reports of 548 consecutive MR examinations of the shoulder were reviewed, looking for mention or description of delamination tears of the rotator cuff. The images of the identified cases were then reviewed by two radiologists to confirm the findings. Correlation with surgical and arthroscopic information was then performed. Delamination tears were defined as horizontal retraction of either the bursal or articular surface of the tendon, manifest as thickening of the torn retracted edge, and/or interstitial splitting of the tendon, manifest as fluid-like high signal intensity on fat-suppressed T2-weighted oblique coronal images. Fourteen cases of delamination tears were identified in 13 patients. Ten of the cases involved the supraspinatus tendon, all with articular surface involvement. Nine of these supraspinatus cases were isolated tears and one occurred as part of a full thickness tear. All 10 of these supraspinatus cases showed medial retraction of the articular surface of the tendon, with thickening of the retracted edge, and 5 of the 10 had a demonstrable horizontal cleft in the interstitium. Four cases involved the subscapularis tendon, with articular surface disruption in three and pure interstitial delamination in one. Medial subluxation of the tendon of the long head of the biceps was present in all four cases. No delamination tears occurred on the bursal surface. Only three of the 14 shoulders underwent surgical repair with one confirmation of supraspinatus delamination, one confirmation of a subscapularis tear that had become a full thickness tear 10 months after initial imaging and another interstitial subscapularis delamination that was not identified arthroscopically. Delamination tears occur most often in the

  18. Achilles tendon healing

    International Nuclear Information System (INIS)

    Dillon, E.H.; Pope, C.F.; Barber, V.; Jokl, P.; Lynch, K.

    1990-01-01

    This paper reports on symptomatic Achilles tendon abnormalities (rupture, tendinitis) evaluated with MR imaging during the healing phase after either surgical or conservative treatment. A total of 21 patients were studied. Fifteen of 21 underwent surgery (13 tendon ruptures) and six were managed conservatively (one rupture). MR studies were obtained before treatment in 11, at 3 months in eight, at 6 months in seven, and at 12 months in 12. The 1.5-T spin-echo and gradient-echo images were correlated with clinical results, planter reflex response times, and calf force measurements. Sequential T2 times were obtained from representative levels in the tendons

  19. Achilles tendon repair

    Science.gov (United States)

    ... your Achilles tendon to point your toes and push off your foot when walking. If your Achilles ... MD, Thompson SR, eds. DeLee and Drez's Orthopaedic Sports Medicine: Principles and Practice . 4th ed. Philadelphia, PA: ...

  20. Achilles Tendon Rupture

    Science.gov (United States)

    ... is a strong fibrous cord that connects the muscles in the back of your calf to your heel bone. If you overstretch your Achilles tendon, it can tear (rupture) completely or just partially. If your Achilles ...

  1. Sheath waves, non collisional dampings

    International Nuclear Information System (INIS)

    Marec, Jean Lucien Ernest

    1974-01-01

    When a metallic conductor is inserted into an ionised gas, an area of electron depletion is formed between the conductor and the plasma: the ionic sheath. Moreover, if the conductor is excited by an electric field, this ionic sheath plays an important role with respect to microwave properties. In this research thesis, the author addresses the range of frequencies smaller than the plasma frequency, and reports the study of resonance phenomena. After a presentation of the problem through a bibliographical study, the author recalls general characteristics of sheath wave propagation and of sheath resonances, and discusses the validity of different hypotheses (for example and among others, electrostatic approximations, cold plasma). Then, the author more particularly addresses theoretical problems related to non collisional dampings: brief bibliographical study, detailed presentation and description of the theoretical model, damping calculation methods. The author then justifies the design and performance of an experiment, indicates measurement methods used to determine plasma characteristics as well as other magnitudes which allow the description of mechanisms of propagation and damping of sheath waves. Experimental results are finally presented with respect to various parameters. The author discusses to which extent the chosen theoretical model is satisfying [fr

  2. Bridging Graft in Irreparable Massive Rotator Cuff Tears: Autogenic Biceps Graft versus Allogenic Dermal Patch Graft.

    Science.gov (United States)

    Rhee, Sung Min; Oh, Joo Han

    2017-12-01

    Few comparative studies have reported on the use of biologic grafts for irreparable massive rotator cuff tears. The purpose of this study was to assess the results of arthroscopic bridging graft in irreparable massive rotator cuff tears using an autogenic long head of biceps tendon (LHBT) or an allogenic dermal patch (ADP). We retrospectively reviewed 24 patients treated using the LHBT (group I) and eight patients with complete rupture of the LHBT treated using an ADP (group II) since 2011. Preoperative Goutallier's fatty degeneration, range of motion (ROM), visual analogue scale (VAS) for pain, American Shoulder and Elbow Surgeons (ASES) score, and Quick Disabilities of the Arm, Shoulder, and Hand (DASH) score were assessed and healing failure was evaluated at 1 year after surgery by ultrasonography or magnetic resonance imaging. The mean fatty degeneration in groups I and II was 3.9 and 3.6 for the supraspinatus ( p = 0.288), 2.7 and 2.9 for the infraspinatus ( p = 0.685), 0.9 and 1.3 for the subscapularis ( p = 0.314), and 1.3 and 3.0 for the teres minor ( p = 0.005), respectively. Subscapularis tears were found in 8 patients (33.3%) in group I and in 7 patients (87.5%) in group II ( p = 0.023). Mean ROMs and functional scores improved significantly in group I (forward flexion: 121.7° to 153.3°, p = 0.010; external rotation: 32.7° to 52.7°, p = 0.001; external rotation at 90°: 63.3° to 74.5°, p = 0.031; internal rotation: T10.5 to T9.3, p = 0.045; VAS: 7.0 to 1.1, p rotator cuff tears, especially in patients with severe fatty degeneration in the teres minor or combined biceps and subscapularis tears.

  3. Self-consistent radial sheath

    International Nuclear Information System (INIS)

    Hazeltine, R.D.

    1988-12-01

    The boundary layer arising in the radial vicinity of a tokamak limiter is examined, with special reference to the TEXT tokamak. It is shown that sheath structure depends upon the self-consistent effects of ion guiding-center orbit modification, as well as the radial variation of E /times/ B-induced toroidal rotation. Reasonable agreement with experiment is obtained from an idealized model which, however simplified, preserves such self-consistent effects. It is argued that the radial sheath, which occurs whenever confining magnetic field-lines lie in the plasma boundary surface, is an object of some intrinsic interest. It differs from the more familiar axial sheath because magnetized charges respond very differently to parallel and perpendicular electric fields. 11 refs., 1 fig

  4. Intrapontine malignant nerve sheath tumor

    DEFF Research Database (Denmark)

    Kozić, Dusko; Nagulić, Mirjana; Samardzić, Miroslav

    2008-01-01

    . On pathological examination, the neoplasm appeared to be an intrapontine nerve sheath tumor originating most likely from the intrapontine segment of one of the cranial nerve fibres. The tumor showed exophytic growth, with consequent spread to adjacent subaracnoid space. MR spectroscopy revealed the presence......The primary source of malignant intracerebral nerve sheath tumors is still unclear We report the imaging and MR spectroscopic findings in a 39-year-old man with a very rare brain stem tumor MR examination revealed the presence of intraaxial brain stem tumor with a partial exophytic growth...

  5. Ulnar-sided pain due to extensor carpi ulnaris tendon subluxation: a case report

    Directory of Open Access Journals (Sweden)

    Cift Hakan

    2012-11-01

    Full Text Available Abstract Introduction We present the case of a patient with extensor carpi ulnaris tendon subluxation who was first treated for distal radioulnar joint sprain. Case presentation A 25-year-old Caucasian man was seen at our policlinic one month after he had fallen on his outstretched hand. A diagnosis of extensor carpi ulnaris subluxation was made clinically but we also had the magnetic resonance imaging scan of the patient’s wrist which displayed an increased signal on T2-weighted images consistent with inflammation around the extensor carpi ulnaris tendon. The extensor carpi ulnaris tendon was found to be dislocating during supination and relocating during pronation. The sheath was reconstructed using extensor retinaculum due to attenuation of subsheath. Conclusion There was no recurrent dislocation of the extensor carpi ulnaris tendon of the patient at his last follow up 12 months after the operation.

  6. [Achilles tendon rupture].

    Science.gov (United States)

    Thermann, H; Hüfner, T; Tscherne, H

    2000-03-01

    The treatment of acute of Achilles tendon rupture experienced a dynamic development in the last ten years. Decisive for this development was the application of MRI and above all the ultrasonography in the diagnostics of the pathological changes and injuries of tendons. The question of rupture morphology as well as different courses of healing could be now evaluated objectively. These advances led consequently to new modalities in treatment concepts and rehabilitation protocols. The decisive input for improvements of the outcome results and particularly the shortening of the rehabilitation period came with introduction of the early functional treatment in contrast to immobilizing plaster treatment. In a prospective randomized study (1987-1989) at the Trauma Dept. of the Hannover Medical School could show no statistical differences comparing functional non-operative with functional operative therapy with a special therapy boot (Variostabil/Adidas). The crucial criteria for therapy selection results from the sonographically measured position of the tendon stumps in plantar flexion (20 degrees). With complete adaptation of the tendons' ends surgical treatment does not achieve better results than non-operative functional treatment in term of tendon healing and functional outcome. Regarding the current therapeutic standards each method has is advantages and disadvantages. Both, the operative and non-operative functional treatment enable a stable tendon healing with a low risk of re-rupture (1-2%). Meanwhile there is consensus for early functional after-treatment of the operated Achilles' tendons. There seems to be a trend towards non-operative functional treatment in cases of adequate sonographical findings, or to minimal invasive surgical techniques.

  7. The 'bridging sign', a MR finding for combined full-thickness tears of the subscapularis tendon and the supraspinatus tendon

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Jin Young [Dept. of Radiology, Saint Paul' s Hospital, The Catholic Univ. of Korea, Seoul (Korea, Republic of); Yoon, Young Cheol; Cha, Dong Ik [Dept. of Radiology, Samsung Medical Center, Sungkyunkwan Univ, School of Medicine, Seoul (Korea, Republic of)], e-mail: ycyoon@skku.edu; Yoo, Jae-Chul [Dept. of Orthopedic Surgery, Samsung Medical Center, Sungkyunkwan Univ. School of Medicine, Seoul (Korea, Republic of); Jung, Jee Young [Dept. of Radiology, School of Medicine, Chung-Ang Univ., Seoul (Korea, Republic of)

    2013-02-15

    Background: In daily practice, we discovered one of the secondary magnetic resonance (MR) findings of the subscapularis (SSC) tendon tear, the 'bridging sign', which has not been previously described. Purpose: To describe the 'bridging sign' on shoulder MR imaging and its radiological and clinical significance in patients with SSC tendon tear. Material and Methods: Twenty-nine patients who had undergone shoulder arthroscopy and had full-thickness tear of the subscapularis tendon were enrolled. The medical records of the 29 patients were retrospectively reviewed for the duration of shoulder pain, rotator cuff tears, and associated arthroscopic findings: biceps tendon abnormality and superior glenoid labral tear. Then, preoperative shoulder MR images were retrospectively reviewed for the presence or absence of the 'bridging sign' and associated MR findings: periarticular fluid and fatty atrophy of the supraspinatus and subscapularis muscles. The type of rotator cuff tear associated with the 'bridging sign' was assessed and the sensitivity, specificity, and accuracy of the 'bridging sign' for the diagnosis of a certain type of rotator cuff tear were calculated. Associated arthroscopic and MR findings and mean duration of the shoulder pain between the patients with and without the 'bridging sign' were compared. Results: The 'bridging sign' was seen in 17 of 29 patients and corresponded to a complex of the torn and superomedially retracted subscapularis tendon, coracohumeral ligament, and superior glenohumeral ligament, adhered to the anterior margin of the torn supraspinatus (SSP) tendon on arthroscopy. All patients with the 'bridging sign' had combined full-thickness tear (FTT) of the cranial 1/2 portion of the subscapularis tendon and anterior 1/2 portion of the SSP tendon. The sensitivity, specificity, and accuracy of the 'bridging sign' for the diagnosis of combined FTTs of

  8. Plasma sheath criterion in thermal electronegative plasmas

    International Nuclear Information System (INIS)

    Ghomi, Hamid; Khoramabadi, Mansour; Ghorannevis, Mahmod; Shukla, Padma Kant

    2010-01-01

    The sheath formation criterion in electronegative plasma is examined. By using a multifluid model, it is shown that in a collisional sheath there will be upper as well as lower limits for the sheath velocity criterion. However, the parameters of the negative ions only affect the lower limit.

  9. An unusual metastasis of lung adenocarcinoma: Biceps brachii muscle

    Directory of Open Access Journals (Sweden)

    Muzaffer Sariaydin

    2016-01-01

    Full Text Available Skeletal muscle metastasis of nonsmall cell lung carcinoma (NSCLC is a rare occurrence, and the most effective treatment modality is currently unknown. In this case presentation, we report a patient with NSCLC who underwent palliative radiotherapy for biceps muscle metastasis of NSLCS. Our case was a 49-year-old woman who had lung adenocarcinoma with biceps muscle metastasis. She had been followed up for 2 years due to Stage IV lung adenocarcinoma from whom a biopsy was taken from a painful mass in right arm that was found to be compatible with metastasis of lung adenocarcinoma. She had palliative radiotherapy for her painful mass and systemic chemotherapy was planned. After palliative radiotherapy, the pain originating from the metastatic mass in right biceps muscle alleviated. Palliative radiotherapy can be a valuable treatment option for cases with skeletal muscle metastasis.

  10. bicep2/KECK ARRAY. IV. OPTICAL CHARACTERIZATION AND PERFORMANCE OF THE bicep2 AND KECK ARRAY EXPERIMENTS

    Energy Technology Data Exchange (ETDEWEB)

    Ade, P. A. R. [School of Physics and Astronomy, Cardiff University, Cardiff, CF24 3AA (United Kingdom); Aikin, R. W.; Bock, J. J.; Brevik, J. A.; Filippini, J. P.; Golwala, S. R.; Hildebrandt, S. R.; Hui, H. [Department of Physics, California Institute of Technology, Pasadena, CA 91125 (United States); Barkats, D. [Joint ALMA Observatory, ESO, Santiago (Chile); Benton, S. J. [Department of Physics, University of Toronto, Toronto, ON (Canada); Bischoff, C. A.; Bradford, K. J.; Buder, I. [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street MS 42, Cambridge, MA 02138 (United States); Bullock, E. [Minnesota Institute for Astrophysics, University of Minnesota, Minneapolis, MN 55455 (United States); Dowell, C. D. [Jet Propulsion Laboratory, Pasadena, CA 91109 (United States); Duband, L. [Université Grenoble Alpes, CEA INAC-SBT, F-38000 Grenoble (France); Fliescher, S. [Department of Physics, University of Minnesota, Minneapolis, MN 55455 (United States); Halpern, M.; Hasselfield, M. [Department of Physics and Astronomy, University of British Columbia, Vancouver, BC (Canada); Hilton, G. C., E-mail: avieregg@kicp.uchicago.edu [National Institute of Standards and Technology, Boulder, CO 80305 (United States); Collaboration: bicep2 and Keck Array Collaborations; and others

    2015-06-20

    bicep2 and the Keck Array are polarization-sensitive microwave telescopes that observe the cosmic microwave background (CMB) from the South Pole at degree angular scales in search of a signature of inflation imprinted as B-mode polarization in the CMB. bicep2 was deployed in late 2009, observed for three years until the end of 2012 at 150 GHz with 512 antenna-coupled transition edge sensor bolometers, and has reported a detection of B-mode polarization on degree angular scales. The Keck Array was first deployed in late 2010 and will observe through 2016 with five receivers at several frequencies (95, 150, and 220 GHz). bicep2 and the Keck Array share a common optical design and employ the field-proven bicep1 strategy of using small-aperture, cold, on-axis refractive optics, providing excellent control of systematics while maintaining a large field of view. This design allows for full characterization of far-field optical performance using microwave sources on the ground. Here we describe the optical design of both instruments and report a full characterization of the optical performance and beams of bicep2 and the Keck Array at 150 GHz.

  11. Efficacy of labral repair, biceps tenodesis, and diagnostic arthroscopy for SLAP Lesions of the shoulder: a randomised controlled trial

    Directory of Open Access Journals (Sweden)

    Mowinckel Petter

    2010-10-01

    Full Text Available Abstract Background Surgery for type II SLAP (superior labral anterior posterior lesions of the shoulder is a promising but unproven treatment. The procedures include labral repair or biceps tenodesis. Retrospective cohort studies have suggested that the benefits of tenodesis include pain relief and improved function, and higher patient satisfaction, which was reported in a prospective non-randomised study. There have been no completed randomised controlled trials of surgery for type II SLAP lesions. The aims of this participant and observer blinded randomised placebo-controlled trial are to compare the short-term (6 months and long-term (2 years efficacy of labral repair, biceps tenodesis, and placebo (diagnostic arthroscopy for alleviating pain and improving function for type II SLAP lesions. Methods/Design A double-blind randomised controlled trial are performed using 120 patients, aged 18 to 60 years, with a history for type II SLAP lesions and clinical signs suggesting type II SLAP lesion, which were documented by MR arthrography and arthroscopy. Exclusion criteria include patients who have previously undergone operations for SLAP lesions or recurrent shoulder dislocations, and ruptures of the rotator cuff or biceps tendon. Outcomes will be assessed at baseline, three, six, 12, and 24 months. Primary outcome measures will be the clinical Rowe Score (1988-version and the Western Ontario Instability Index (WOSI at six and 24 months. Secondary outcome measures will include the Shoulder Instability Questionnaire (SIQ, the generic EuroQol (EQ-5 D and EQ-VAS, return to work and previous sports activity, complications, and the number of reoperations. Discussion The results of this trial will be of international importance and the results will be translatable into clinical practice. Trial Registration [ClinicalTrials.gov NCT00586742

  12. BICEP2. II. Experiment and three-year data set

    Energy Technology Data Exchange (ETDEWEB)

    Ade, P. A. R. [School of Physics and Astronomy, Cardiff University, Cardiff, CF24 3AA (United Kingdom); Aikin, R. W.; Bock, J. J.; Brevik, J. A.; Filippini, J. P.; Golwala, S. R.; Hildebrandt, S. R. [Department of Physics, California Institute of Technology, Pasadena, CA 91125 (United States); Amiri, M.; Davis, G.; Halpern, M.; Hasselfield, M. [Department of Physics and Astronomy, University of British Columbia, Vancouver, BC (Canada); Barkats, D. [Joint ALMA Observatory, ESO, Santiago (Chile); Benton, S. J. [Department of Physics, University of Toronto, Toronto, ON (Canada); Bischoff, C. A.; Buder, I. [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street MS 42, Cambridge, MA 02138 (United States); Bullock, E. [Minnesota Institute for Astrophysics, University of Minnesota, Minneapolis, MN 55455 (United States); Day, P. K.; Dowell, C. D. [Jet Propulsion Laboratory, Pasadena, CA 91109 (United States); Duband, L. [Université Grenoble Alpes, CEA INAC-SBT, F-38000 Grenoble (France); Fliescher, S., E-mail: ogburn@stanford.edu [Department of Physics, University of Minnesota, Minneapolis, MN 55455 (United States); Collaboration: Bicep2 Collaboration; and others

    2014-09-01

    We report on the design and performance of the BICEP2 instrument and on its three-year data set. BICEP2 was designed to measure the polarization of the cosmic microwave background (CMB) on angular scales of 1°-5°(ℓ = 40-200), near the expected peak of the B-mode polarization signature of primordial gravitational waves from cosmic inflation. Measuring B-modes requires dramatic improvements in sensitivity combined with exquisite control of systematics. The BICEP2 telescope observed from the South Pole with a 26 cm aperture and cold, on-axis, refractive optics. BICEP2 also adopted a new detector design in which beam-defining slot antenna arrays couple to transition-edge sensor (TES) bolometers, all fabricated on a common substrate. The antenna-coupled TES detectors supported scalable fabrication and multiplexed readout that allowed BICEP2 to achieve a high detector count of 500 bolometers at 150 GHz, giving unprecedented sensitivity to B-modes at degree angular scales. After optimization of detector and readout parameters, BICEP2 achieved an instrument noise-equivalent temperature of 15.8 μK√s. The full data set reached Stokes Q and U map depths of 87.2 nK in square-degree pixels (5.'2 μK) over an effective area of 384 deg{sup 2} within a 1000 deg{sup 2} field. These are the deepest CMB polarization maps at degree angular scales to date. The power spectrum analysis presented in a companion paper has resulted in a significant detection of B-mode polarization at degree scales.

  13. Ion acceleration in the plasma source sheath

    International Nuclear Information System (INIS)

    Birdsall, C.K.

    1986-01-01

    This note is a calculation of the potential drop for a planar plasma source, across the source sheath, into a uniform plasma region defined by vector E = 0 and/or perhaps ∂ 2 PHI/∂ x 2 = 0. The calculation complements that of Bohm who obtained the potential drop at the other end of a plasma, at a planar collector sheath. The result is a relation between the source ion flux and the source sheath potential drop and the accompanying ion acceleration. This planar source sheath ion acceleration mechanism (or that from a distributed source) can provide the pre-collector-sheath ion acceleration as found necessary by Bohm. 3 refs

  14. Extracorporeal shockwave therapy and therapeutic exercise for supraspinatus and biceps tendinopathies in 29 dogs.

    Science.gov (United States)

    Leeman, J J; Shaw, K K; Mison, M B; Perry, J A; Carr, A; Shultz, R

    2016-10-15

    Supraspinatus tendinopathy (ST) and biceps tendinopathy (BT) are common causes of forelimb lameness in large-breed dogs and have historically been treated with conservative management or surgery. Extracorporeal shockwave therapy (ESWT) and therapeutic exercise (TE) are thought to be treatment options for these conditions. The objectives of this study were to report the clinical presentations of dogs treated with ESWT for shoulder tendinopathies, to determine the association between shoulder lesion severity identified on ultrasonography or MRI and outcome, and to compare the outcomes of dogs treated with ESWT with and without TE. Medical records of 29 dogs diagnosed with shoulder tendinopathies and treated with ESWT were reviewed, and 24 dogs were diagnosed with either unilateral BT or BT and ST. None were found to have unilateral ST. Five dogs were diagnosed with bilateral disease. Eighty-five per cent of dogs had good or excellent outcomes determined by owner assessment 11-220 weeks after therapy. Outcomes were found to be better as tendon lesion severity increased (P=0.0497), regardless if ESWT was performed with or without TE (P=0.92). ESWT should be considered a safe primary therapeutic option for canine shoulder tendinopathies. Larger controlled prospective studies are needed to adequately assess these findings. British Veterinary Association.

  15. Tendon tissue engineering and its role on healing of the experimentally induced large tendon defect model in rabbits: a comprehensive in vivo study.

    Science.gov (United States)

    Meimandi-Parizi, Abdolhamid; Oryan, Ahmad; Moshiri, Ali

    2013-01-01

    Healing of large tendon defects is challenging. We studied the role of collagen implant with or without polydioxanone (PDS) sheath on the healing of a large Achilles tendon defect model, in rabbits. Sixty rabbits were divided into three groups. A 2 cm gap was created in the left Achilles tendon of all rabbits. In the control lesions, no implant was used. The other two groups were reconstructed by collagen and collagen-PDS implants respectively. The animals were clinically examined at weekly intervals and their lesions were observed by ultrasonography. Blood samples were obtained from the animals and were assessed for hematological analysis and determination of serum PDGF level, at 60 days post injury (DPI). The animals were then euthanized and their lesions were assessed for gross and histopathology, scanning electron microscopy, biomechanical testing, dry matter and hydroxyproline content. Another 65 pilot animals were also studied grossly and histopathologically to define the host implant interaction and graft incorporation at serial time points. The treated animals gained significantly better clinical scoring compared to the controls. Treatment with collagen and collagen-PDS implants significantly increased the biomechanical properties of the lesions compared to the control tendons at 60DPI (Ptendon. Implantation of the bioimplants had a significant role in initiating tendon healing and the implants were biocompatible, biodegradable and safe for application in tendon reconstructive surgery. The results of the present study may be valuable in clinical practice.

  16. Chaotic inflation in supergravity after Planck and BICEP2

    International Nuclear Information System (INIS)

    Kallosh, Renata; Linde, Andrei

    2014-05-01

    We discuss the general structure and observational consequences of some of the simplest versions of chaotic inflation in supergravity in relation to the data by Planck 2013 and BICEP2. We show that minimal modifications to the simplest quadratic potential are sufficient to provide a controllable tensor mode signal and a suppression of CMB power at large angular scales.

  17. Inflation in the light of BICEP2 and PLANCK

    Indian Academy of Sciences (India)

    2016-01-13

    Jan 13, 2016 ... The BICEP2/Keck+PLANCK joint analysis of the -model polarization and polarization by foreground dust sets an upper bound on the tensor-to-scalar ratio of 0.05 < 0.12 at 95% CL. The popular Starorbinsky model Higgs-inflation or the conformally equivalent Higgs-inflation model allow low values ...

  18. Flexor Tendon Injuries

    Science.gov (United States)

    ... All Topics A-Z Videos Infographics Symptom Picker Anatomy Bones Joints Muscles Nerves Vessels Tendons About Hand Surgery What is ... Hand Therapist? Media Find a Hand Surgeon Home Anatomy ... fields From * To * DESCRIPTION The muscles that bend (flex) the fingers are called flexor ...

  19. triceps tendon avulsion

    African Journals Online (AJOL)

    GB

    2014-01-01

    Jan 1, 2014 ... trauma. Systemic causes such as chronic renal failure, steriod use, diabetes mellitus, hyperparathyroidism, rheumatoid arthritis, osteogensis imperfecta and local causes like local steriod injection, olecranon bursitis and attritional changes due to degenerative arthritis are associated with tendon weakening.

  20. Non-Maxwellian plasma sheaths

    International Nuclear Information System (INIS)

    Haines, M.G.

    1998-01-01

    There is much experimental evidence that heat flux to divertor plates or to limiters is very asymmetric. For example, Lowry made measurements on poloidal limiters in JET, Stangeby and McCracken reported asymmetries in several experiments. In 1991 Haines considered the effects on the Child-Langmuir sheaths of having a net current flow. It was found that a sheath that receives more ions than electrons receives more energy flux than a sheath that receives more electrons than ions. We now extend the model to include for the electrons departures from a Maxwellian distribution arising from a net current flow, heat flow and thermoelectric effects in the scrape-off layer (SOL). It is envisaged that a net current flows in the SOL due to applied or induced electric fields, and is of a magnitude similar to that in the adjacent bulk plasma, though reduced due to the lower temperature in the SOL. We employ conventional linear transport theory eg. Braginskii, Epperlein and Haines in which the ions are a stationary Maxwellian. (orig.)

  1. Changes in hip joint muscle-tendon lengths with mode of locomotion.

    Science.gov (United States)

    Riley, Patrick O; Franz, Jason; Dicharry, Jay; Kerrigan, D Casey

    2010-02-01

    We have reported that peak hip extension is nearly identical in walking and running, suggesting that anatomical constraints, such as flexor muscle tightness may limit the range of hip extension. To obtain a more mechanistic insight into mobility at the hip and pelvis we examined the lengths of the muscle-tendons units crossing the hip joint. Data defining the three-dimensional kinematics of 26 healthy runners at self-selected walking and running speeds were obtained. These data were used to scale and drive musculoskeletal models using OpenSIM. Muscle-tendon unit (MTU) lengths were calculated for the trailing limb illiacus, rectus femoris, gluteus maximus, and biceps femoris long head and the advancing limb biceps femoris and gluteus maximus. The magnitude and timing of MTU length peaks were each compared between walking and running. The peak length of the right (trailing limb) illiacus MTU, a pure hip flexor, was nearly identical between walking and running, while the maximum length of the rectus femoris MTU, a hip flexor and knee extensor, increased during running. The maximum length of the left (leading limb) biceps femoris was also unchanged between walking and running. Further, the timing of peak illiacus MTU length and peak contralateral biceps femoris MTU length occurred essentially simultaneously during running, at a time during gait when the hamstrings are most vulnerable to stretch injury. This latter finding suggests exploring the role for hip flexor stretching in combination with hamstring stretching to treat and/or prevent running related hamstring injury. Copyright 2009 Elsevier B.V. All rights reserved.

  2. Novel fiber-based pure chitosan scaffold for tendon augmentation: biomechanical and cell biological evaluation.

    Science.gov (United States)

    Nowotny, J; Aibibu, D; Farack, J; Nimtschke, U; Hild, M; Gelinsky, M; Kasten, P; Cherif, Ch

    2016-07-01

    One possibility to improve the mechanical properties after tendon ruptures is augmentation with a scaffold. Based on wet spinning technology, chitosan fibres were processed to a novel pure high-grade multifilament yarn with reproducible quality. The fibres were braided to obtain a 3D tendon scaffold. The CS fibres and scaffolds were evaluated biomechanically and compared to human supraspinatus (SSP) tendons. For the cytobiological characterization, in vitro cell culture experiments with human mesenchymal stem cells (hMSC) were performed. Three types of 3D circular braided scaffolds were fabricated. Significantly, higher ultimate stress values were measured for scaffold with larger filament yarn, compared to scaffold with smaller filament yarn. During cultivation over 28 days, the cells showed in dependence of isolation method and/or donor a doubling or tripling of the cell number or even a six-fold increase on the CS scaffold, which was comparable to the control (polystyrene) or in the case of cells obtained from human biceps tendon even higher proliferation rates. After 14 days, the scaffold surface was covered homogeneously with a cell layer. In summary, the present work demonstrates that braided chitosan scaffolds constitute a straightforward approach for designing tendon analogues, maintaining important flexibility in scaffold design and providing favourable mechanical properties of the resulting construct.

  3. RF sheaths for arbitrary B field angles

    Science.gov (United States)

    D'Ippolito, Daniel; Myra, James

    2014-10-01

    RF sheaths occur in tokamaks when ICRF waves encounter conducting boundaries and accelerate electrons out of the plasma. Sheath effects reduce the efficiency of ICRF heating, cause RF-specific impurity influxes from the edge plasma, and increase the plasma-facing component damage. The rf sheath potential is sensitive to the angle between the B field and the wall, the ion mobility and the ion magnetization. Here, we obtain a numerical solution of the non-neutral rf sheath and magnetic pre-sheath equations (for arbitrary values of these parameters) and attempt to infer the parametric dependences of the Child-Langmuir law. This extends previous work on the magnetized, immobile ion regime. An important question is how the rf sheath voltage distributes itself between sheath and pre-sheath for various B field angles. This will show how generally previous estimates of the rf sheath voltage and capacitance were reasonable, and to improve the RF sheath BC. Work supported by US DOE grants DE-FC02-05ER54823 and DE-FG02-97ER54392.

  4. Fixation Strength of Polyetheretherketone Sheath-and-Bullet Device for Soft Tissue Repair in the Foot and Ankle.

    Science.gov (United States)

    Christensen, Jay; Fischer, Brian; Nute, Michael; Rizza, Robert

    Tendon transfers are often performed in the foot and ankle. Recently, interference screws have been a popular choice owing to their ease of use and fixation strength. Considering the benefits, one disadvantage of such devices is laceration of the soft tissues by the implant threads during placement that potentially weaken the structural integrity of the grafts. A shape memory polyetheretherketone bullet-in-sheath tenodesis device uses circumferential compression, eliminating potential damage from thread rotation and maintaining the soft tissue orientation of the graft. The aim of this study was to determine the pullout strength and failure mode for this device in both a synthetic bone analogue and porcine bone models. Thirteen mature bovine extensor tendons were secured into ten 4.0 × 4.0 × 4.0-cm cubes of 15-pound per cubic foot solid rigid polyurethane foam bone analogue models or 3 porcine femoral condyles using the 5 × 20-mm polyetheretherketone soft tissue anchor. The bullet-in-sheath device demonstrated a mean pullout of 280.84 N in the bone analog models and 419.47 N in the porcine bone models. (p = .001). The bullet-in-sheath design preserved the integrity of the tendon graft, and none of the implants dislodged from their original position. Copyright © 2017 The American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  5. Ultrasound diagnosis of rectus sheath hematoma

    International Nuclear Information System (INIS)

    Hwang, M. S.; Chang, J. C.; Rhee, C. B.

    1984-01-01

    6 cases of rectus sheath hematoma were correctly diagnosed by ultrasound. 2 cases had bilateral rectus sheath hematoma and 4 cases were unilateral. On ultrasound finding, relatively well defined oval or spindle like cystic mass situated in the area of rectus muscle on all cases. Ultrasound examination may give more definite diagnosis and extension rectus sheath hematoma and also helpful to follow up study of hematoma

  6. Contribution of full-thickness supraspinatus tendon tears to acquired subcoracoid impingement

    Energy Technology Data Exchange (ETDEWEB)

    MacMahon, P.J. [Department of Radiology, Cappagh National Orthopaedic Hospital, Finglas, Dublin (Ireland)]. E-mail: petermacmahon@yahoo.com; Taylor, D.H. [Department of Radiology, Cappagh National Orthopaedic Hospital, Finglas, Dublin (Ireland); Duke, D. [Department of Radiology, Cappagh National Orthopaedic Hospital, Finglas, Dublin (Ireland); Brennan, D.D. [Department of Radiology, Cappagh National Orthopaedic Hospital, Finglas, Dublin (Ireland); O' Brien, J. [Department of Radiology, Cappagh National Orthopaedic Hospital, Finglas, Dublin (Ireland); Eustace, S.J. [Department of Radiology, Cappagh National Orthopaedic Hospital, Finglas, Dublin (Ireland)

    2007-06-15

    Aim: To assess the relationship between the severity of full-thickness supraspinatus tendon tears and the development of subcoracoid impingement. Materials and methods: Fifty-one magnetic resonance imaging (MRI) shoulder examination reports with full-thickness supraspinatus tears were retrospectively identified and reviewed by two dedicated musculoskeletal radiologists. The appearances of the rotator cuff muscles, biceps tendon and the lesser tubercle were recorded. The acromio-humeral distance and the axial coraco-humeral distance were measured. The data were recorded and analysed electronically. Results: The kappa values for inter-observer agreement were: 0.91 for acromio-humeral distance and 0.85 for coraco-humeral distance measurements. Twenty-six patients had significant retraction of the supraspinatus tendon, 85% (22 cases) of this group had imaging evidence of tear or tendonopathy of the subscapularis tendon. Twenty-five patients had no significant retraction of the supraspinatus, 56% (14 cases) of this group had imaging evidence of a subscapularis tear or tendonopathy. The acromio-humeral distance was significantly less in patients with supraspinatus tears and retraction (p < 0.05). The subscapularis tendon was significantly more likely to be abnormal if the supraspinatus was retracted than if no retraction was present (p < 0.05). There were no significant differences in coraco-humeral distances between the groups. Conclusion: Subscapularis tendon signal and structural changes are frequently associated with full-thickness supraspinatus tendon tears, particularly if the supraspinatus is significantly retracted. In this static MRI series, the data do not support the occurrence of classical subcoracoid impingement as an aetiology; however, they may support the possibility of a dynamic mechanism, to which future studies could be directed.

  7. Contribution of full-thickness supraspinatus tendon tears to acquired subcoracoid impingement

    International Nuclear Information System (INIS)

    MacMahon, P.J.; Taylor, D.H.; Duke, D.; Brennan, D.D.; O'Brien, J.; Eustace, S.J.

    2007-01-01

    Aim: To assess the relationship between the severity of full-thickness supraspinatus tendon tears and the development of subcoracoid impingement. Materials and methods: Fifty-one magnetic resonance imaging (MRI) shoulder examination reports with full-thickness supraspinatus tears were retrospectively identified and reviewed by two dedicated musculoskeletal radiologists. The appearances of the rotator cuff muscles, biceps tendon and the lesser tubercle were recorded. The acromio-humeral distance and the axial coraco-humeral distance were measured. The data were recorded and analysed electronically. Results: The kappa values for inter-observer agreement were: 0.91 for acromio-humeral distance and 0.85 for coraco-humeral distance measurements. Twenty-six patients had significant retraction of the supraspinatus tendon, 85% (22 cases) of this group had imaging evidence of tear or tendonopathy of the subscapularis tendon. Twenty-five patients had no significant retraction of the supraspinatus, 56% (14 cases) of this group had imaging evidence of a subscapularis tear or tendonopathy. The acromio-humeral distance was significantly less in patients with supraspinatus tears and retraction (p < 0.05). The subscapularis tendon was significantly more likely to be abnormal if the supraspinatus was retracted than if no retraction was present (p < 0.05). There were no significant differences in coraco-humeral distances between the groups. Conclusion: Subscapularis tendon signal and structural changes are frequently associated with full-thickness supraspinatus tendon tears, particularly if the supraspinatus is significantly retracted. In this static MRI series, the data do not support the occurrence of classical subcoracoid impingement as an aetiology; however, they may support the possibility of a dynamic mechanism, to which future studies could be directed

  8. Novel methods for tendon investigations

    DEFF Research Database (Denmark)

    Kjær, Michael; Langberg, Henning; Bojsen-Møller, J.

    2008-01-01

    Purpose. Tendon structures have been studied for decades, but over the last decade, methodological development and renewed interest for metabolic, circulatory and tissue protein turnover in tendon tissue has resulted in a rising amount of investigations. Method. This paper will detail the various...... modern investigative techniques available to study tendons. Results. There are a variety of investigative methods available to study the correlations between mechanics and biology in tendons. Conclusion. The available methodologies not only allow for potential insight into physiological...... and pathophysiological mechanisms in tendon tissue, but also, to some extent, allow for more elaborate studies of the intact human tendon. Read More: http://informahealthcare.com/doi/full/10.1080/09638280701785403...

  9. Ultrastructure of the extracellular matrix of bovine dura mater, optic nerve sheath and sclera.

    Science.gov (United States)

    Raspanti, M; Marchini, M; Della Pasqua, V; Strocchi, R; Ruggeri, A

    1992-10-01

    The sclera, the outermost sheath of the optic nerve and the dura mater have been investigated histologically and ultrastructurally. Although these tissues appear very similar under the light microscope, being dense connective tissues mainly composed of collagen bundles and a limited amount of cells and elastic fibres, they exhibit subtle differences on electron microscopy. In the dura and sclera collagen appears in the form of large, nonuniform fibrils, similar to those commonly found in tendons, while in the optic nerve sheath the fibrils appear smaller and uniform, similar to those commonly observed in reticular tissues, vessel walls and skin. Freeze-fracture also reveals these fibrils to have different subfibrillar architectures, straight or helical, which correspond to 2 distinct forms of collagen fibril previously described (Raspanti et al. 1989). The other extracellular matrix components also vary with the particular collagen fibril structure. Despite their common embryological derivation, the dura mater, optic nerve sheath and sclera exhibit diversification of their extracellular matrix consistent with the mechanical loads to which these tissues are subjected. Our observations indicate that the outermost sheath of the optic nerve resembles the epineurium of peripheral nerves rather than the dura to which it is commonly likened.

  10. Retroperitoneal and rectus sheath hematomas.

    Science.gov (United States)

    Kasotakis, George

    2014-02-01

    The retroperitoneum is rich in vascular structures and can harbor large hematomas, traumatic or spontaneous. The management of retroperitoneal hematomas depends on the mechanism of injury and whether they are pulsatile/expanding. Rectus sheath hematomas are uncommon abdominal wall hematomas secondary to trauma to the epigastric arteries of the rectus muscle. The common risk factors include anticoagulation, strenuous exercise, coughing, coagulation disorders, and invasive procedures on/through the abdominal wall. The management is largely supportive, with the reversal of anticoagulation and transfusions; angioembolization may be necessary. Copyright © 2014 Elsevier Inc. All rights reserved.

  11. Simultaneous bilateral patellar tendon rupture ?

    OpenAIRE

    Moura, Diogo Lino; Marques, Jos? Pedro; Lucas, Francisco Manuel; Fonseca, Fernando Pereira

    2016-01-01

    Bilateral patellar tendon rupture is a rare entity, often associated with systemic diseases and patellar tendinopathy. The authors report a rare case of a 34-year-old man with simultaneous bilateral rupture of the patellar tendon caused by minor trauma. The patient is a retired basketball player with no past complaints of chronic knee pain and a history of steroid use. Surgical management consisted in primary end-to-end tendon repair protected temporarily with cerclage wiring, followed by a s...

  12. Isolated Tuberculous Tenosynovitis of the Anterior Tibial and Extensor Digitorum Longus Tendons

    Directory of Open Access Journals (Sweden)

    Berhan Genç

    2013-01-01

    Full Text Available Musculoskeletal system is involved in 1-5% of extrapulmonary cases of tuberculosis. Tuberculous tenosynovitis is a rare form of musculoskeletal tuberculosis. Tuberculosis of the tendon sheath in the hand has been seen in a few cases. Involvement of the tendons of the leg is less common. Diagnosis is not easy as there are no specific clinical symptoms or signs. A 33-year-old male presented with painful swelling in the distal right lower limb that caused restriction of movement. Imaging studies showed inflammation and infection of the extensor digitorium longus and tibialis anterior tendons. Histopathological studies showed a necrotizing granulomatous inflammation in the synovial tissue. A diagnosis of tuberculosis was made and medical treatment was initiated that proved successful. Patient remained infection-free at 26-month follow-up examination.

  13. Inflation in the light of BICEP2 and PLANCK

    Indian Academy of Sciences (India)

    Abstract. The BICEP2/Keck+PLANCK joint analysis of the B-model polarization and polar- ization by foreground dust sets an upper bound on the tensor-to-scalar ratio of r0.05 < 0.12 at 95%. CL. The popular Starorbinsky model Higgs-inflation or the conformally equivalent Higgs-inflation model allow low r values (∼10−3).

  14. Long head of biceps: from anatomy to treatment

    Directory of Open Access Journals (Sweden)

    Marco Sarmento

    2015-01-01

    Full Text Available The long head of the biceps (LHB, tendinous structure of the proximal brachial biceps, has its well-known anatomy, which contrasts with its current functional characterization. Various forms of proximal anchor and intra–articular route, important for the correct interpretation of its contribution to the pathology of the shoulder as well as the treatment methodology, are described. Knowledge of its biomechanics results mainly from cadaveric studies that contradict each other. Already the few studies in vivo indicate a depressant and stabilizing action, anterior, for the humeral head. Its pathology is rarely isolated because it is almost always correlated with rotator cuff or labrum pathology. It can be divided into 3 major groups (inflammatory, instability and traumatic and subdivided according to its location. The anterior shoulder pain is the initial symptom of pathology of LHB Its perfect characterization is dependent on the associated injuries. Clinical tests are multiple and only their combination allows better sensitivity and specificity for LHB pathology. The arthro-MRI and dynamic ultrasound are able to increase proper diagnostic of the pathology of LHB. Treatment ranges from conservative and surgical. The latter includes the repair, tenotomy and tenodesis of LHB which can be performed by open or arthroscopic methodology. The author intends to review existing literature on all aspects related to the long head of the biceps from anatomy to treatment, presenting the latest results.

  15. Primary optic nerve sheath meningioma

    Energy Technology Data Exchange (ETDEWEB)

    Jeremic, Branislav [International Atomic Energy Agency, Vienna (Austria); Pitz, Susanne (eds.) [University Eye Hospital, Mainz (Germany)

    2008-07-01

    Optic nerve sheath meningioma (ONSM) is a rare tumour. Cases are usually separated into primary ONSM, which arises either intraorbitally or, less commonly, intracanalicularly, and secondary ONSM, which arises intracranially and subsequently invades the optic canal and orbit. This is the first book to cover all important aspects of the diagnosis and treatment of primary ONSM. After a general introduction, individual chapters discuss the clinical presentation, clinical examination and diagnosis, imaging, and histology. Treatment options are then addressed in detail, with special emphasis on external beam radiation therapy, and in particular stereotactic fractionated radiation therapy. The latter has recently produced consistently good results and is now considered the emerging treatment of choice for the vast majority of patients with primary ONSM. This well-illustrated book will prove invaluable to all practitioners who encounter primary ONSM in their clinical work. (orig.)

  16. MR anatomy study of the elbow, with emphasis in ligaments and tendons structure - methodology

    International Nuclear Information System (INIS)

    Vilela, Sonia de Aguiar; Fernandes, Artur da Rocha Correa; Barbieri, Antonio; Turrini, Elisabete; Juliano, Yara

    1999-01-01

    Seventeen MR exams of the elbow joints of fifteen healthy volunteers were obtained on T1 spin-echo sequences in the transversal, coronal and sagital planes. Eight anatomic structures were selected and evaluated by three independent blind readers. The aim of this study was to establish the frequency of visibility as well to determine the best plane to characterize these anatomic structures and also to analyze the interobserver variability. The readers analyzed the exams using the same criteria: degree 0 (structure not visible); degree 1 (structure visible and partially delineated); degree 2 (structure well visible and well delineated). The structure visibility showed variability close related to the degree (1 or 2) chosen by the readers to define the structure visualization and mainly in the transverse plane. The coronal plane was showed to be the ideal to evaluate the collateral ligaments, the common extensor tendon and the com,mon flexor tendon, otherwise the sagital plane was useful to define triceps and braquial tendons. The biceps tendon and annular ligament were well defined in the transverse plane. The usefulness of this study is to establish the ideal planes to evaluate these anatomic structures, and develop faster protocols. (author)

  17. Three-dimensional analysis of antenna sheaths

    International Nuclear Information System (INIS)

    Myra, J.R.; D'Ippolito, D.A.; Ho, Y.L.

    1996-01-01

    The present work is motivated by the importance of r.f. sheaths in determining the antenna-plasma interaction and the sensitivity of the sheaths to the complicated three-dimensional structure of modern ion cyclotron range of frequency (ICRF) antennas. To analyze r.f. sheaths on the plasma facing regions of the launcher, we first calculate the contact points of the tokamak magnetic field lines on the surface of the antenna Faraday screen and nearby limiters for realistic three-dimensional magnetic flux surface and antenna geometries. Next, the r.f. voltage that can drive sheaths at the contact points is determined and used to assess the resulting sheath power dissipation, r.f.-driven sputtering, and r.f.-induced convective cells (which produce edge profile modification). The calculations are embodied in a computer code, ANSAT (antenna sheath analysis tool), and sample ANSAT runs are shown to highlight the physics- and geometry-dependent characteristics of the r.f. sheaths and their relationship to the antenna design. One use of ANSAT is therefore as a design tool, to assess the strengths and weaknesses of a given design with respect to critical voltage handling and edge plasma interaction issues. Additionally, examples are presented where ANSAT has been useful in the analysis and interpretation of ICRF experiments (orig.)

  18. Biceps brachii muscle oxygenation in electrical muscle stimulation.

    Science.gov (United States)

    Muthalib, Makii; Jubeau, Marc; Millet, Guillaume Y; Maffiuletti, Nicola A; Ferrari, Marco; Nosaka, Kazunori

    2010-09-01

    The purpose of this study was to compare between electrical muscle stimulation (EMS) and maximal voluntary (VOL) isometric contractions of the elbow flexors for changes in biceps brachii muscle oxygenation (tissue oxygenation index, TOI) and haemodynamics (total haemoglobin volume, tHb = oxygenated-Hb + deoxygenated-Hb) determined by near-infrared spectroscopy (NIRS). The biceps brachii muscle of 10 healthy men (23-39 years) was electrically stimulated at high frequency (75 Hz) via surface electrodes to evoke 50 intermittent (4-s contraction, 15-s relaxation) isometric contractions at maximum tolerated current level (EMS session). The contralateral arm performed 50 intermittent (4-s contraction, 15-s relaxation) maximal voluntary isometric contractions (VOL session) in a counterbalanced order separated by 2-3 weeks. Results indicated that although the torque produced during EMS was approximately 50% of VOL (P<0.05), there was no significant difference in the changes in TOI amplitude or TOI slope between EMS and VOL over the 50 contractions. However, the TOI amplitude divided by peak torque was approximately 50% lower for EMS than VOL (P<0.05), which indicates EMS was less efficient than VOL. This seems likely because of the difference in the muscles involved in the force production between conditions. Mean decrease in tHb amplitude during the contraction phases was significantly (P<0.05) greater for EMS than VOL from the 10th contraction onwards, suggesting that the muscle blood volume was lower in EMS than VOL. It is concluded that local oxygen demand of the biceps brachii sampled by NIRS is similar between VOL and EMS.

  19. Rectus sheath abscess after laparoscopic appendicectomy

    Directory of Open Access Journals (Sweden)

    Golash Vishwanath

    2007-01-01

    Full Text Available Port site wound infection, abdominal wall hematoma and intraabdominal abscess formation has been reported after laparoscopic appendicectomy. We describe here a rectus sheath abscess which occurred three weeks after the laparoscopic appendicectomy. It was most likely the result of secondary infection of the rectus sheath hematoma due to bleeding into the rectus sheath from damage to the inferior epigastric arteries or a direct tear of the rectus muscle. As far as we are aware this complication has not been reported after laparoscopic appendicectomy.

  20. Nonsingular bouncing cosmologies in light of BICEP2

    International Nuclear Information System (INIS)

    Cai, Yi-Fu; Quintin, Jerome; Saridakis, Emmanuel N.; Wilson-Ewing, Edward

    2014-01-01

    We confront various nonsingular bouncing cosmologies with the recently released BICEP2 data and investigate the observational constraints on their parameter space. In particular, within the context of the effective field approach, we analyze the constraints on the matter bounce curvaton scenario with a light scalar field, and the new matter bounce cosmology model in which the universe successively experiences a period of matter contraction and an ekpyrotic phase. Additionally, we consider three nonsingular bouncing cosmologies obtained in the framework of modified gravity theories, namely the Hořava-Lifshitz bounce model, the f(T) bounce model, and loop quantum cosmology

  1. Bioreactor Design for Tendon/Ligament Engineering

    OpenAIRE

    Wang, Tao; Gardiner, Bruce S.; Lin, Zhen; Rubenson, Jonas; Kirk, Thomas B.; Wang, Allan; Xu, Jiake; Smith, David W.; Lloyd, David G.; Zheng, Ming H.

    2012-01-01

    Tendon and ligament injury is a worldwide health problem, but the treatment options remain limited. Tendon and ligament engineering might provide an alternative tissue source for the surgical replacement of injured tendon. A bioreactor provides a controllable environment enabling the systematic study of specific biological, biochemical, and biomechanical requirements to design and manufacture engineered tendon/ligament tissue. Furthermore, the tendon/ligament bioreactor system can provide a s...

  2. Simultaneous bilateral patellar tendon rupture.

    Science.gov (United States)

    Moura, Diogo Lino; Marques, José Pedro; Lucas, Francisco Manuel; Fonseca, Fernando Pereira

    2017-01-01

    Bilateral patellar tendon rupture is a rare entity, often associated with systemic diseases and patellar tendinopathy. The authors report a rare case of a 34-year-old man with simultaneous bilateral rupture of the patellar tendon caused by minor trauma. The patient is a retired basketball player with no past complaints of chronic knee pain and a history of steroid use. Surgical management consisted in primary end-to-end tendon repair protected temporarily with cerclage wiring, followed by a short immobilization period and intensive rehabilitation program. Five months after surgery, the patient was able to fully participate in sport activities.

  3. Simultaneous bilateral patellar tendon rupture

    Directory of Open Access Journals (Sweden)

    Diogo Lino Moura

    Full Text Available ABSTRACT Bilateral patellar tendon rupture is a rare entity, often associated with systemic diseases and patellar tendinopathy. The authors report a rare case of a 34-year-old man with simultaneous bilateral rupture of the patellar tendon caused by minor trauma. The patient is a retired basketball player with no past complaints of chronic knee pain and a history of steroid use. Surgical management consisted in primary end-to-end tendon repair protected temporarily with cerclage wiring, followed by a short immobilization period and intensive rehabilitation program. Five months after surgery, the patient was able to fully participate in sport activities.

  4. Implantation of a novel biologic and hybridized tissue engineered bioimplant in large tendon defect: an in vivo investigation.

    Science.gov (United States)

    Oryan, Ahmad; Moshiri, Ali; Parizi, Abdolhamid Meimandi; Maffulli, Nicola

    2014-02-01

    Surgical reconstruction of large Achilles tendon defects is technically demanding. There is no standard method, and tissue engineering may be a valuable option. We investigated the effects of 3D collagen and collagen-polydioxanone sheath (PDS) implants on a large tendon defect model in rabbits. Ninety rabbits were divided into three groups: control, collagen, and collagen-PDS. In all groups, 2 cm of the left Achilles tendon were excised and discarded. A modified Kessler suture was applied to all injured tendons to retain the gap length. The control group received no graft, the treated groups were repaired using the collagen only or the collagen-PDS prostheses. The bioelectrical characteristics of the injured areas were measured at weekly intervals. The animals were euthanized at 60 days after the procedure. Gross, histopathological and ultrastructural morphology and biophysical characteristics of the injured and intact tendons were investigated. Another 90 pilot animals were also used to investigate the inflammatory response and mechanism of graft incorporation during tendon healing. The control tendons showed severe hyperemia and peritendinous adhesion, and the gastrocnemius muscle of the control animals showed severe atrophy and fibrosis, with a loose areolar connective tissue filling the injured area. The tendons receiving either collagen or collagen-PDS implants showed lower amounts of peritendinous adhesion, hyperemia and muscle atrophy, and a dense tendon filled the defect area. Compared to the control tendons, application of collagen and collagen-PDS implants significantly improved water uptake, water delivery, direct transitional electrical current and tissue resistance to direct transitional electrical current. Compared to the control tendons, both prostheses showed significantly increased diameter, density and alignment of the collagen fibrils and maturity of the tenoblasts at ultrastructure level. Both prostheses influenced favorably tendon healing

  5. Rectus sheath hematoma: three case reports

    Directory of Open Access Journals (Sweden)

    Kapan Selin

    2008-01-01

    Full Text Available Abstract Introduction Rectus sheath hematoma is an uncommon cause of acute abdominal pain. It is an accumulation of blood in the sheath of the rectus abdominis, secondary to rupture of an epigastric vessel or muscle tear. It could occur spontaneously or after trauma. They are usually located infraumblically and often misdiagnosed as acute abdomen, inflammatory diseases or tumours of the abdomen. Case presentation We reported three cases of rectus sheath hematoma presenting with a mass in the abdomen and diagnosed by computerized tomography. The patients recovered uneventfully after bed rest, intravenous fluid replacement, blood transfusion and analgesic treatment. Conclusion Rectus sheath hematoma is a rarely seen pathology often misdiagnosed as acute abdomen that may lead to unnecessary laparotomies. Computerized tomography must be chosen for definitive diagnosis since ultrasonography is subject to error due to misinterpretation of the images. Main therapy is conservative management.

  6. Joint Analysis of BICEP2/Keck Array and Planck Data

    DEFF Research Database (Denmark)

    Ade, P. A. R.; Aghanim, N.; Ahmed, Z.

    2015-01-01

    We report the results of a joint analysis of data from BICEP2/Keck Array and Planck. BICEP2 and Keck Array have observed the same approximately 400 deg2 patch of sky centered on RA 0 h, Dec. -57.5°. The combined maps reach a depth of 57 nK deg in Stokes Q and U in a band centered at 150 GHz. Planck...... GHz to a lensed-ΛCDM model that includes dust and a possible contribution from inflationary gravitational waves (as parametrized by the tensor-to-scalar ratio r), using a prior on the frequency spectral behavior of polarized dust emission from previous Planck analysis of other regions of the sky. We...... present an alternative analysis which is similar to a map-based cleaning of the dust contribution, and show that this gives similar constraints. The final result is expressed as a likelihood curve for r, and yields an upper limit r 0.05

  7. Tendon overuse syndrome: imaging diagnosis

    International Nuclear Information System (INIS)

    Huber, W.; Nehrer, S.; Muellner, T.; Kainberger, F.; Ulreich, N.; Bernhard, C.; Imhof, H.

    2001-01-01

    Injuries of muscles and tendons occur commonly during various sporting activities and in most cases the athletes feel such an accident to be sudden and unavoidable. The rupture of a tendon, however, has to be considered in many cases as the final stage of a long-standing progressive degeneration of collagen fibers. This process con be described as 'tendon overuse syndrome (TOS)'. Diagnostic imaging modalities, especially sonography and MRI, are suitable to detect and analyse the different stages of this syndrome and the degree of morphological abnormalities. The first stage is painful functional derangement, followed by tendovaginitis, peritendinitis, or bursitis. The third stage is tendinosis resulting from biomechanical or ischaemic injury of tendon fibers which may eventually be followed by partial or complete rupture. Regional or individual specifications of these four stages may occur at anatomically predisposing sites, so-called critical zones, or during periods of specific proneness, the vulnerable phases. (author)

  8. Theory of the Electron Sheath and Presheath

    Science.gov (United States)

    Scheiner, Brett; Baalrud, Scott; Yee, Benjamin; Hopkins, Matthew; Barnat, Edward

    2015-09-01

    Electron sheaths are commonly found near Langmuir probes collecting the electron saturation current. The common assumption is that the probe collects the random flux of electrons incident on the sheath, which tacitly implies that there is no electron presheath and that the flux collected is due to a velocity space truncation of the velocity distribution function (VDF). This work provides a dedicated theory of electron sheaths, which suggests that electron sheaths are not so simple. Motivated by VDFs observed in recent Particle-In-Cell (PIC) simulations, we develop a 1D model for the electron sheath and presheath. In the model, under low temperature plasma conditions, an electron pressure gradient accelerates electrons in the presheath to a flow velocity that exceeds the electron thermal speed at the sheath edge. This pressure gradient allows the generation of large flows compared to those that would be generated by the electric field alone. It is due to this pressure gradient that the electron presheath extends much further into the plasma (nominally by a factor of √{mi /me }) than an analogous ion presheath. Results of the model are compared with PIC simulations. This work was supported by the Office of Fusion Energy Science at the U.S. Department of Energy under contract DE-AC04-94SL85000 and by the Office of Science Graduate Student Research (SCGSR) program under Contract Number DE-AC05-06OR23100.

  9. A sheath model for arbitrary radiofrequency waveforms

    Science.gov (United States)

    Turner, M. M.; Chabert, Pascal

    2012-10-01

    The sheath is often the most important region of a rf plasma, because discharge impedance, power absorption and ion acceleration are critically affected by the behaviour of the sheath. Consequently, models of the sheath are central to any understanding of the physics of rf plasmas. Lieberman has supplied an analytical model for a radio-frequency sheath driven by a single frequency, but in recent years interest has been increasing in radio-frequency discharges excited by increasingly complex wave forms. There has been limited success in generalizing the Lieberman model in this direction, because of mathematical complexities. So there is essentially no sheath model available to describe many modern experiments. In this paper we present a new analytical sheath model, based on a simpler mathematical framework than that of Lieberman. For the single frequency case, this model yields scaling laws that are identical in form to those of Lieberman, differing only by numerical coefficients close to one. However, the new model may be straightforwardly solved for arbitrary current waveforms, and may be used to derive scaling laws for such complex waveforms. In this paper, we will describe the model and present some illustrative examples.

  10. Chiasma crurale: intersection of the tibialis posterior and flexor digitorum longus tendons above the ankle. Magnetic resonance imaging-anatomic correlation in cadavers

    Energy Technology Data Exchange (ETDEWEB)

    Buck, Florian M. [VA San Diego Medical Center, Department of Radiology, San Diego, CA (United States); Institut fuer Diagnostische Radiologie, Zurich (Switzerland); Gheno, Ramon; Nico, Marcelo A.C.; Trudell, Debra J.; Resnick, Donald [VA San Diego Medical Center, Department of Radiology, San Diego, CA (United States); Haghighi, Parviz [VA San Diego Medical Center, Department of Pathology, San Diego, CA (United States)

    2010-06-15

    To determine the precise anatomy and magnetic resonance (MR) imaging appearance of the chiasma crurale in cadavers, paying special attention to degenerative changes Twelve fresh human ankles were harvested from 11 nonembalmed cadavers (mean age at death 77 years) and used according to institutional guidelines. MR imaging and MR tenography were used to investigate the anatomy of the chiasma crurale using proton density-weighted sequences. The gross anatomy of the chiasma crurale was evaluated and compared to the MR imaging findings. Histology was used to elucidate further the structure of the chiasma crurale. Above the chiasma, five specimens had a small amount of fat tissue between the tibialis posterior and flexor digitorum longus tendon. In all specimens both tendons had a sheath below the chiasma but not above it. At the central portion of the chiasma there was no soft tissue between the tendons, except in two specimens that showed an anatomic variant consisting of a thick septum connecting the tibial periosteum and the deep transverse fascia of the leg. In MR images, eight specimens showed what were believed to be degenerative changes in the tendons at the level of the chiasma. However, during gross inspection and histologic analysis of the specimens, there was no tendon degeneration visible. At the central portion of the chiasma, there is no tissue between the tibialis posterior and flexor digitorum longus tendons unless there is an anatomic variant. At the chiasma crurale, areas with irregular tendon surfaces are normal findings and are not associated with tendon degeneration (fraying). (orig.)

  11. How to Patch Active Plasma and Collisionless Sheath: Practical Guide

    International Nuclear Information System (INIS)

    Kaganovich, Igor D.

    2002-01-01

    Most plasmas have a very thin sheath compared with the plasma dimension. This necessitates separate calculations of the plasma and sheath. The Bohm criterion provides the boundary condition for calculation of plasma profiles. To calculate sheath properties, a value of electric field at the plasma-sheath interface has to be specified in addition to the Bohm criterion. The value of the boundary electric field and robust procedure to approximately patch plasma and collisionless sheath with a very good accuracy are reported

  12. Proximal biceps rupture: management of an unusual injury in an arm wrestler

    OpenAIRE

    Pratt, D A; Tennent, T D

    2007-01-01

    Arm wrestling may cause unusual injuries, which may require operative repair in the sporting individual. Injury to the proximal biceps as a consequence of arm wrestling has not been reported previously. The diagnosis and treatment of a 36‐year‐old man who sustained a proximal biceps rupture while arm wrestling and his operative management are described.

  13. Extensor and flexor digit synovial sheath, sac and synovial capsule in the distal part of the limbs in buffalos and camels and its relation of surgical interference

    Directory of Open Access Journals (Sweden)

    S. AL-sadi

    2010-01-01

    Full Text Available Sixty one samples of the distal parts of limbs were obtained from different ages of buffalo and camels of both sex to study the synovial structures to determine the suitable sites for injection of surgical interference. The result showed that extensor digit synovial sheath was extend between middle or distal part of metacarpal (metatarsal to the extensor processes and this formed with synovial capsule dorsal pouches which serve in surgical interference. The flexor digit synovial sheath extended to palmar (planter between distal extremity of metacarpal (metatarsal to the middle of second phalanx in buffalo while in camel it extended to the proximal extremity of second phalanx, that sheath was formed with suspensory ligament and sessamoid bone palmar or planter pouches which were serve the surgical interference. Fourth synovial bursa observed situated dorsally between the extensor digit laterals tendon and capsule of fetlock joint, forms site of injection during surgical interference, while the other two synovial bursa were located to palmer (planter between deep flexor tendon and distal sessamoid bone in buffalo while in camel these bursa were located between deep flexor tendon and cartilage of the second phalanx, these bursa were served for surgical interference. The synovial capsule which serve the surgical interference through digit cushion these were shown extended from the claw capsule. The result show that surgical interference was form six pouches in buffalo and eight pouches in camel, which formed by synovial structures and the tissue associated with them.

  14. Radiative inflation and dark energy RIDEs again after BICEP2

    International Nuclear Information System (INIS)

    Bari, Pasquale Di; King, Stephen F.; Merle, Alexander; Luhn, Christoph; Schmidt-May, Angnis

    2014-01-01

    Following the ground-breaking measurement of the tensor-to-scalar ratio r=0.20 +0.07 -0.05 by the BICEP2 collaboration, we perform a statistical analysis of a model that combines Radiative Inflation with Dark Energy (RIDE) based on the M 2 |Φ| 2 ln(|Φ| 2 /Λ 2 ) potential and compare its predictions to those based on the traditional chaotic inflation M 2 |Φ| 2 potential. We find a best-fit value in the RIDE model of r=0.18 as compared to r=0.17 in the chaotic model, with the spectral index being n S =0.96 in both models

  15. Probing nuclear rates with Planck and BICEP2

    CERN Document Server

    Di Valentino, Eleonora; Lesgourgues, Julien; Mangano, Gianpiero; Melchiorri, Alessandro; Miele, Gennaro; Pisanti, Ofelia

    2014-01-01

    Big Bang Nucleosynthesis (BBN) relates key cosmological parameters to the primordial abundance of light elements. In this paper, we point out that the recent observations of Cosmic Microwave Background anisotropies by the Planck satellite and by the BICEP2 experiment constrain these parameters with such a high level of accuracy that the primordial deuterium abundance can be inferred with remarkable precision. For a given cosmological model, one can obtain independent information on nuclear processes in the energy range relevant for BBN, which determine the eventual ^2H/H yield. In particular, assuming the standard cosmological model, we show that a combined analysis of Planck data and of recent deuterium abundance measurements in metal-poor damped Lyman-alpha systems provides independent information on the cross section of the radiative capture reaction d(p,\\gamma)^3He converting deuterium into helium. Interestingly, the result is higher than the values suggested by a fit of present experimental data in the B...

  16. Quantifying the BICEP2-Planck tension over gravitational waves.

    Science.gov (United States)

    Smith, Kendrick M; Dvorkin, Cora; Boyle, Latham; Turok, Neil; Halpern, Mark; Hinshaw, Gary; Gold, Ben

    2014-07-18

    The recent BICEP2 measurement of B-mode polarization in the cosmic microwave background (r = 0.2(-0.05)(+0.07)), a possible indication of primordial gravity waves, appears to be in tension with the upper limit from WMAP (r < 0.13 at 95% C.L.) and Planck (r < 0.11 at 95% C.L.). We carefully quantify the level of tension and show that it is very significant (around 0.1% unlikely) when the observed deficit of large-scale temperature power is taken into account. We show that measurements of TE and EE power spectra in the near future will discriminate between the hypotheses that this tension is either a statistical fluke or a sign of new physics. We also discuss extensions of the standard cosmological model that relieve the tension and some novel ways to constrain them.

  17. bicep2/ KECK ARRAY . IV. OPTICAL CHARACTERIZATION AND PERFORMANCE OF THE bicep2 AND KECK ARRAY EXPERIMENTS

    Energy Technology Data Exchange (ETDEWEB)

    Ade, P.A.R.; Aikin, R.W.; Barkats, D.; Benton, S.J.; Bischoff, C.A.; Bock, J.J.; Bradford, K.J.; Brevik, J.A.; Buder, I.; Bullock, E.; Dowell, C.D.; Duband, L.; Filippini, J.P.; Fliescher, S.; Golwala, S.R.; Halpern, M.; Hasselfield, M.; Hildebrandt, S.R.; Hilton, G.C.; Hui, H.; Irwin, K.D.

    2015-06-18

    bicep2/KECK ARRAY. IV. OPTICAL CHARACTERIZATION AND PERFORMANCE OF THE bicep2 AND KECK ARRAY EXPERIMENTS P. A. R. Ade1, R. W. Aikin2, D. Barkats3, S. J. Benton4, C. A. Bischoff5, J. J. Bock2,6, K. J. Bradford5, J. A. Brevik2, I. Buder5, E. Bullock7Show full author list Published 2015 June 18 • © 2015. The American Astronomical Society. All rights reserved. The Astrophysical Journal, Volume 806, Number 2 Article PDF Figures Tables References Citations 273 Total downloads Cited by 6 articles Turn on MathJax Share this article Get permission to re-use this article Article information Abstract bicep2 and the Keck Array are polarization-sensitive microwave telescopes that observe the cosmic microwave background (CMB) from the South Pole at degree angular scales in search of a signature of inflation imprinted as B-mode polarization in the CMB. bicep2 was deployed in late 2009, observed for three years until the end of 2012 at 150 GHz with 512 antenna-coupled transition edge sensor bolometers, and has reported a detection of B-mode polarization on degree angular scales. The Keck Array was first deployed in late 2010 and will observe through 2016 with five receivers at several frequencies (95, 150, and 220 GHz). bicep2 and the Keck Array share a common optical design and employ the field-proven bicep1 strategy of using small-aperture, cold, on-axis refractive optics, providing excellent control of systematics while maintaining a large field of view. This design allows for full characterization of far-field optical performance using microwave sources on the ground. Here we describe the optical design of both instruments and report a full characterization of the optical performance and beams of bicep2 and the Keck Array at 150 GHz.

  18. Plasma sheath in non-Maxwellian plasma

    International Nuclear Information System (INIS)

    Shimizu, Takuo; Horigome, Takashi

    1992-01-01

    Reviewing many theoretical and experimental works on the electron-energy distributions (EEDF) of various plasmas, we point out that many plasmas have EEDF of non-Maxwellian in shape. Therefore, the recent treatment of plasma sheath using the Maxwell-Boltzmann distribution approximation should be improved. To do this, we have adopted Rutcher's standard distribution as a generalized form in place of the traditional Maxwellian, and found that the minimum energy of ions entering the sheath edge (Bohm's criterion) varies largely, and have also shown the variation of Debye length with the shape of EEDF. The length is the most important parameter to proceed with more detailed analysis on plasma-sheaths, and also to control them in the future. (author)

  19. Achilles Tendon's Tear

    OpenAIRE

    F. Shahandeh

    2008-01-01

    Introduction: The achilles and plantaris tendons to-gether makeup the posterior grouptendons of ankle. Their seldom confusion in interpreting MR images of the achilles tendon. The achilles tendon should ap-pear informally straight and black on sagital T1 weighted images and on fluid sensitive images."nCase Presentation: After a heavy sport, a 55 year-old woman cannot walk with right foot."nDiscussion: The classic achilles tendon rupture occurs with forced dorsiflexion of planted foo...

  20. The effect of a collagen-elastin matrix on adhesion formation after flexor tendon repair in a rabbit model.

    Science.gov (United States)

    Wichelhaus, Dagmar Alice; Beyersdoerfer, Sascha Tobias; Gierer, Philip; Vollmar, Brigitte; Mittlmeier, Th

    2016-07-01

    The outcome of flexor tendon surgery is negatively affected by the formation of adhesions which can occur during the healing of the tendon repair. In this experimental study, we sought to prevent adhesion formation by wrapping a collagen-elastin scaffold around the repaired tendon segment. In 28 rabbit hind legs, the flexor tendons of the third and fourth digits were cut and then repaired using a two-strand suture technique on the fourth digit and a four-strand technique on the third digit. Rabbits were randomly assigned to study and control groups. In the control group, the operation ended by closing the tendon sheath and the skin. In the study group, a collagen-elastin scaffold was wrapped around the repaired tendon segment in both digits. After 3 and 8 weeks, the tendons were harvested and processed histologically. The range of motion of the digits and the gap formation between the repaired tendon ends were measured. The formation of adhesions, infiltration of leucocytes and extracellular inflammatory response were quantified. At the time of tendon harvesting, all joints of the operated toes showed free range of motion. Four-strand core sutures lead to significantly less diastasis between the repaired tendon ends than two-strand core suture repairs. The collagen-elastin scaffold leads to greater gapping after 3 weeks compared to the controls treated without the matrix. Within the tendons treated with the collagen-elastin matrix, a significant boost of cellular and extracellular inflammation could be stated after 3 weeks which was reflected by a higher level of CAE positive cells and more formation of myofibroblasts in the αSMA stain in the study group. The inflammatory response subsided gradually and significantly until the late stage of the study. Both the cellular and extracellular inflammatory response was emphasized with the amount of material used for the repair. The use of a collagen-elastin matrix cannot be advised for the prevention of adhesion

  1. Pathophysiology of overuse tendon injury

    International Nuclear Information System (INIS)

    Kannus, P.; Paavola, M.; Paakkala, T.; Parkkari, J.; Jaervinen, T.; Jaervinen, M.

    2002-01-01

    Overuse tendon injury is one of the most common injuries in sports.The etiology as well as the pathophysilogical mechanisms leading to tendinopathy are of crucial medical importance.At the moment intrinsic and extrinsic factors are assumed as mechanisms of overuse tendon injury. Except for the acute, extrinsic trauma, the chronic overuse tendon injury is a multifactorial process. There are many other factors, such as local hypoxia, less of nutrition, impaired metabolism and local inflammatory that may also contribute to the development of tissue damage.The exact interaction of these factors cannot be explained entirely at the moment.Further studies will be necessary in order to get more information. (orig.) [de

  2. Isocurvature perturbations and tensor mode in light of Planck and BICEP2

    Energy Technology Data Exchange (ETDEWEB)

    Kawasaki, Masahiro; Yokoyama, Shuichiro [Institute for Cosmic Ray Research, University of Tokyo, Kashiwa 277-8582 (Japan); Sekiguchi, Toyokazu [Helsinki Institute of Physics, University of Helsinki, PO Box 64, FIN-00014 (Finland); Takahashi, Tomo, E-mail: kawasaki@icrr.u-tokyo.ac.jp, E-mail: toyokazu.sekiguchi@helsinki.fi, E-mail: tomot@cc.saga-u.ac.jp, E-mail: shu@icrr.u-tokyo.ac.jp [Department of Physics, Saga University, Saga 840-8502 (Japan)

    2014-08-01

    We investigate the degeneracy of the isocurvature perturbations and the primordial gravitational waves, by using recent observations of the cosmic microwave background (CMB) reported by Planck and BICEP2 collaborations. We show that the tension in the bound on the tensor-to-scalar ratio r between Planck and BICEP2 can be resolved by introducing the anti-correlated isocurvature perturbations. Quantitatively, we find that with the anti-correlated isocurvature perturbations the constraints on r from Planck alone and BICEP2 results can be consistent at 68 % C.L.

  3. Optic Nerve Sheath Meningocele: A Case Report

    Science.gov (United States)

    Halimi, E.; Wavreille, O.; Rosenberg, R.; Bouacha, I.; Lejeune, J.-P.; Defoort-Dhellemmes, S.

    2013-01-01

    Abstract Isolated optic nerve sheath meningocele is a rare affection defined as the cystic enlargement of the optic nerve sheath filled with cerebrospinal fluid. We report the case of a 39-year-old woman presenting with bilateral meningocele uncovered during a routine examination for headache complaints. A 5-year follow-up validated the lesion’s clinical and imaging stability. Magnetic resonance imaging (MRI) is an essential tool in the diagnosis of this pathology, alongside characteristic symptoms indicating that the meningocele might have progressively expanded into the orbit. In this case we present a therapeutic approach based on pathophysiological hypotheses and review of the literature. PMID:28163760

  4. Spontaneous Achilles tendon rupture in alkaptonuria | Mohammed ...

    African Journals Online (AJOL)

    Spontaneous Achilles tendon ruptures are uncommon. We present a 46-year-old man with spontaneous Achilles tendon rupture due to ochronosis. To our knowledge, this has not been previously reported in Sudan literature. The tendon of the reported patient healed well after debridement and primary repairs.

  5. Can PRP effectively treat injured tendons?

    Science.gov (United States)

    Wang, James H-C

    2014-01-01

    PRP is widely used to treat tendon and other tissue injuries in orthopaedics and sports medicine; however, the efficacy of PRP treatment on injured tendons is highly controversial. In this commentary, I reason that there are many PRP- and patient-related factors that influence the outcomes of PRP treatment on injured tendons. Therefore, more basic science studies are needed to understand the mechanism of PRP on injured tendons. Finally, I suggest that better understanding of the PRP action mechanism will lead to better use of PRP for the effective treatment of tendon injuries in clinics.

  6. Arthroscopic sheath design and technical evaluation

    NARCIS (Netherlands)

    Tuijthof, Gabriëlle J. M.; Blankevoort, Leendert; Herder, Just L.; van Dijk, C. Niek

    2009-01-01

    The maintenance of a clear view on the operation area is essential to perform a minimally invasive procedure In arthroscopy, this is achieved by irrigating the Joint with a saline fluid that is pumped through the joint At present the arthroscopic sheaths are not designed for optimal irrigation,

  7. Evaluation of the effectiveness of kinesiotaping in reducing delayed onset muscle soreness of the biceps brachii

    Directory of Open Access Journals (Sweden)

    Boguszewski Dariusz

    2016-07-01

    Full Text Available biological regeneration in athletes. The aim of this study was to evaluate the effectiveness of the application of lymphatic kinesiotaping in reducing delayed onset muscle soreness of biceps brachii.

  8. Bioreactor design for tendon/ligament engineering.

    Science.gov (United States)

    Wang, Tao; Gardiner, Bruce S; Lin, Zhen; Rubenson, Jonas; Kirk, Thomas B; Wang, Allan; Xu, Jiake; Smith, David W; Lloyd, David G; Zheng, Ming H

    2013-04-01

    Tendon and ligament injury is a worldwide health problem, but the treatment options remain limited. Tendon and ligament engineering might provide an alternative tissue source for the surgical replacement of injured tendon. A bioreactor provides a controllable environment enabling the systematic study of specific biological, biochemical, and biomechanical requirements to design and manufacture engineered tendon/ligament tissue. Furthermore, the tendon/ligament bioreactor system can provide a suitable culture environment, which mimics the dynamics of the in vivo environment for tendon/ligament maturation. For clinical settings, bioreactors also have the advantages of less-contamination risk, high reproducibility of cell propagation by minimizing manual operation, and a consistent end product. In this review, we identify the key components, design preferences, and criteria that are required for the development of an ideal bioreactor for engineering tendons and ligaments.

  9. Smart Tendon Actuated Flexible Actuator

    Directory of Open Access Journals (Sweden)

    Md. Masum Billah

    2015-01-01

    Full Text Available We investigate the kinematic feasibility of a tendon-based flexible parallel platform actuator. Much of the research on tendon-driven Stewart platforms is devoted either to the completely restrained positioning mechanism (CRPM or to one particular type of the incompletely restrained positioning mechanism (IRPM where the external force is provided by the gravitational pull on the platform such as in cable-suspended Stewart platforms. An IRPM-based platform is proposed which uses the external force provided by a compliant member. The compliant central column allows the configuration to achieve n DOFs with n tendons. In particular, this investigation focuses on the angular deflection of the upper platform with respect to the lower platform. The application here is aimed at developing a linkable module that can be connected to one another so as to form a “snake robot” of sorts. Since locomotion takes precedence over positioning in this application, a 3-DOF Stewart platform is adopted. For an arbitrary angular displace of the end-effector, the corresponding length of each tendon can be determined through inverse kinematics. Mathematical singularities are investigated using the traditional analytical method of defining the Jacobian.

  10. Adaptive tracking for pneumatic muscle actuators in bicep and tricep configurations.

    Science.gov (United States)

    Lilly, John H

    2003-09-01

    Adaptive tracking techniques are applied to pneumatic muscle actuators arranged in bicep and tricep configurations. The control objective is to force the joint angle to track a specified reference path. Mathematical models are derived for the bicep and tricep configurations. The models are nonlinear and in general time-varying, making adaptive control desirable. Stability results are derived, and the results of simulation studies are presented, contrasting the nonlinear adaptive control to a nonadaptive PID control approach.

  11. Voluntary activation of biceps-to-triceps and deltoid-to-triceps transfers in quadriplegia.

    Science.gov (United States)

    Peterson, Carrie L; Bednar, Michael S; Bryden, Anne M; Keith, Michael W; Perreault, Eric J; Murray, Wendy M

    2017-01-01

    The biceps or the posterior deltoid can be transferred to improve elbow extension function for many individuals with C5 or C6 quadriplegia. Maximum strength after elbow reconstruction is variable; the patient's ability to voluntarily activate the transferred muscle to extend the elbow may contribute to the variability. We compared voluntary activation during maximum isometric elbow extension following biceps transfer (n = 5) and deltoid transfer (n = 6) in three functional postures. Voluntary activation was computed as the elbow extension moment generated during maximum voluntary effort divided by the moment generated with full activation, which was estimated via electrical stimulation. Voluntary activation was on average 96% after biceps transfer and not affected by posture. Individuals with deltoid transfer demonstrated deficits in voluntary activation, which differed by posture (80% in horizontal plane, 69% in overhead reach, and 70% in weight-relief), suggesting inadequate motor re-education after deltoid transfer. Overall, individuals with a biceps transfer better activated their transferred muscle than those with a deltoid transfer. This difference in neural control augmented the greater force-generating capacity of the biceps leading to increased elbow extension strength after biceps transfer (average 9.37 N-m across postures) relative to deltoid transfer (average 2.76 N-m across postures) in our study cohort.

  12. Tenderization effect of soy sauce on beef M. biceps femoris.

    Science.gov (United States)

    Kim, Hyun-Wook; Choi, Yun-Sang; Choi, Ji-Hun; Kim, Hack-Youn; Lee, Mi-Ai; Hwang, Ko-Eun; Song, Dong-Heon; Lim, Yun-Bin; Kim, Cheon-Jei

    2013-08-15

    This study was conducted to evaluate the tenderization effect of soy sauce on beef M. biceps femoris (BF). Five marinades were prepared with 4% (w/v) sodium chloride and 25% (w/v) soy sauce solutions (4% salt concentration) and mixed with the ratios of 100:0 (S0, pH 6.52), 75:25 (S25, 5.40) 50:50 (S50, 5.24), 25:75 (S75, 5.05), and 0:100 (S100, 4.85), respectively. The BF samples which were obtained from Hanwoo cows at 48 h postmortem (n=24) were marinated with five marinades for 72 h at 4°C (1:4 w/w), and the effects of soy sauce on tenderness were evaluated. Soy sauce marination resulted in a decrease in the pH value of the BF sample. However, there were no significant differences in the water holding capacity (Psauce may attribute various mechanisms such as increased collagen solubility or proteolysis which depend on soy sauce level in marinade. Copyright © 2013 Elsevier Ltd. All rights reserved.

  13. Hyperuricemic PRP in Tendon Cells

    Directory of Open Access Journals (Sweden)

    I. Andia

    2014-01-01

    Full Text Available Platelet-rich plasma (PRP is injected within tendons to stimulate healing. Metabolic alterations such as the metabolic syndrome, diabetes, or hyperuricemia could hinder the therapeutic effect of PRP. We hypothesise that tendon cells sense high levels of uric acid and this could modify their response to PRP. Tendon cells were treated with allogeneic PRPs for 96 hours. Hyperuricemic PRP did not hinder the proliferative actions of PRP. The gene expression pattern of inflammatory molecules in response to PRP showed absence of IL-1b and COX1 and modest expression of IL6, IL8, COX2, and TGF-b1. IL8 and IL6 proteins were secreted by tendon cells treated with PRP. The synthesis of IL6 and IL8 proteins induced by PRP is decreased significantly in the presence of hyperuricemia (P = 0.017 and P = 0.012, resp.. Concerning extracellular matrix, PRP-treated tendon cells displayed high type-1 collagen, moderate type-3 collagen, decorin, and hyaluronan synthase-2 expression and modest expression of scleraxis. Hyperuricemia modified the expression pattern of extracellular matrix proteins, upregulating COL1 (P = 0.036 and COMP (P = 0.012 and downregulating HAS2 (P = 0.012. Positive correlations between TGF-b1 and type-1 collagen (R = 0.905, P = 0.002 and aggrecan (R = 0.833, P = 0.010 and negative correlations between TGF-b1 and IL6 synthesis (R = −0.857, P = 0.007 and COX2 (R = −0.810, P = 0.015 were found.

  14. Tendon vibration attenuates superficial venous vessel response of the resting limb during static arm exercise

    Directory of Open Access Journals (Sweden)

    Ooue Anna

    2012-11-01

    Full Text Available Abstract Background The superficial vein of the resting limb constricts sympathetically during exercise. Central command is the one of the neural mechanisms that controls the cardiovascular response to exercise. However, it is not clear whether central command contributes to venous vessel response during exercise. Tendon vibration during static elbow flexion causes primary muscle spindle afferents, such that a lower central command is required to achieve a given force without altering muscle force. The purpose of this study was therefore to investigate whether a reduction in central command during static exercise with tendon vibration influences the superficial venous vessel response in the resting limb. Methods Eleven subjects performed static elbow flexion at 35% of maximal voluntary contraction with (EX + VIB and without (EX vibration of the biceps brachii tendon. The heart rate, mean arterial pressure, and rating of perceived exertion (RPE in overall and exercising muscle were measured. The cross-sectional area (CSAvein and blood velocity of the basilic vein in the resting upper arm were assessed by ultrasound, and blood flow (BFvein was calculated using both variables. Results Muscle tension during exercise was similar between EX and EX + VIB. However, RPEs at EX + VIB were lower than those at EX (P P vein in the resting limb at EX decreased during exercise from baseline (P vein at EX + VIB did not change during exercise. CSAvein during exercise at EX was smaller than that at EX + VIB (P vein did not change during the protocol under either condition. The decreases in circulatory response and RPEs during EX + VIB, despite identical muscle tension, showed that activation of central command was less during EX + VIB than during EX. Abolishment of the decrease in CSAvein during exercise at EX + VIB may thus have been caused by a lower level of central command at EX + VIB rather than EX. Conclusion Diminished central command induced by tendon

  15. Results of treatment of the calcific tendinitis of the shoulder supraspinatus muscle tendon

    Directory of Open Access Journals (Sweden)

    S. S. Strafun

    2017-12-01

    Full Text Available The aim of the study was to identify and compare the results of conservative and surgical treatment of the calcific tendinitis of the shoulder supraspinatus muscle tendon. Materials and methods. The clinical group consisted of 120 patients with calcific tendinitis of supraspinatus tendon. All patients were divided into two groups, according to the operative or conservative treatment, each of these groups have been subdivided into two (with calcific deposits less or more than 1.5 cm in length according to Bosworth radiological classification. Conservative treatment ("needling" included: evacuation of calcific deposits with saline under ultrasound control with subsequent injection of prolonged corticosteroid into the subacromial space, use of nonsteroid anti-inflammatory drugs, physiotherapy. Surgical treatment included: evacuation of calcium deposits from the tendon followed by rotator cuff repair and biceps tendon tenodesis at the proximal third of the intertubercular groove. Results. In the majority of patients, after the "needling" of little - 1.5 cm calcific deposits (55 patients - 45.8% clinical and radiographic healing occurred in 2 weeks after procedure. The level of pain in average was 2,39 ± 0,39 points according to VAS scale and function of the shoulder joint has increased in average to 40,26 ± 4,39 points on Oxford Shoulder Score. In 3 months after treatment begining, the best average results were obtained in patients with calcific deposits less than 1.5 cm - 43 ± 3,8 points on Oxford Shoulder Score, the worst 26 ± 4,8 points - in patients with calcific deposits bigger than 1.5 cm who underwent conservative treatment (р≤0,05. Conclusions. In group of patients after surgical treatment, size of calcific deposits did not significantly affect the treatment result (р≤0,01. Slightly better results were obtained in patients with calcific deposits size less than1.5 cm - 39 ± 3,8 points on Oxford Shoulder Score.

  16. Toward an understanding of foreground emission in the BICEP2 region

    International Nuclear Information System (INIS)

    Flauger, Raphael; Hill, J. Colin; Spergel, David N.

    2014-01-01

    BICEP2 has reported the detection of a degree-scale B-mode polarization pattern in the Cosmic Microwave Background (CMB) and has interpreted the measurement as evidence for primordial gravitational waves. Motivated by the profound importance of the discovery of gravitational waves from the early Universe, we examine to what extent a combination of Galactic foregrounds and lensed E-modes could be responsible for the signal. We reanalyze the BICEP2 results and show that the 100 ×150 GHz and 150 ×150 GHz data are consistent with a cosmology with r=0.2 and negligible foregrounds, but also with a cosmology with r=0 and a significant dust polarization signal. We give independent estimates of the dust polarization signal in the BICEP2 region using a number of different approaches: (1) data-driven models based on Planck 353 GHz intensity, polarization fractions inferred from the same Planck data used by the BICEP2 team but corrected for CMB and CIB contributions, and polarization angles from starlight polarization data or the Planck sky model; (2) the same set of pre-Planck models used by the BICEP2 team but taking into account the higher polarization fractions observed in the CMB- and CIB-corrected map; (3) a measurement of neutral hydrogen gas column density N HI in the BICEP2 region combined with an extrapolation of a relation between HI column density and dust polarization derived by Planck; and (4) a dust polarization map based on digitized Planck data, which we only use as a final cross-check. While these approaches are consistent with each other, the expected amplitude of the dust polarization power spectrum remains uncertain by about a factor of three. The lower end of the prediction leaves room for a primordial contribution, but at the higher end the dust in combination with the standard CMB lensing signal could account for the BICEP2 observations, without requiring the existence of primordial gravitational waves. By measuring the cross-correlations between the

  17. Magnetotherapy: The quest for tendon regeneration.

    Science.gov (United States)

    Pesqueira, Tamagno; Costa-Almeida, Raquel; Gomes, Manuela E

    2018-05-09

    Tendons are mechanosensitive tissues that connect and transmit the forces generated by muscles to bones by allowing the conversion of mechanical input into biochemical signals. These physical forces perform the fundamental work of preserving tendon homeostasis assuring body movements. However, overloading causes tissue injuries, which leads us to the field of tendon regeneration. Recently published reviews have broadly shown the use of biomaterials and different strategies to attain tendon regeneration. In this review, our focus is the use of magnetic fields as an alternative therapy, which has demonstrated clinical relevance in tendon medicine because of their ability to modulate cell fate. Yet the underlying cellular and molecular mechanisms still need to be elucidated. While providing a brief outlook about specific signalling pathways and intracellular messengers as framework in play by tendon cells, application of magnetic fields as a subcategory of physical forces is explored, opening up a compelling avenue to enhance tendon regeneration. We outline here useful insights on the effects of magnetic fields both at in vitro and in vivo levels, particularly on the expression of tendon genes and inflammatory cytokines, ultimately involved in tendon regeneration. Subsequently, the potential of using magnetically responsive biomaterials in tendon tissue engineering is highlighted and future directions in magnetotherapy are discussed. © 2018 Wiley Periodicals, Inc.

  18. Ipsilateral free semitendinosus tendon graft transfer for reconstruction of chronic tears of the Achilles tendon

    Directory of Open Access Journals (Sweden)

    Gougoulias Nikolaos

    2008-07-01

    Full Text Available Abstract Background Many techniques have been developed for the reconstruction of the Achilles tendon in chronic tears. In presence of a large gap (greater than 6 centimetres, tendon augmentation is required. Methods We present our method of minimally invasive semitendinosus reconstruction for the Achilles tendon using one para-midline and one midline incision. Results The first incision is a 5 cm longitudinal incision, made 2 cm proximal and just medial to the palpable end of the residual tendon. The second incision is 3 cm long and is also longitudinal but is 2 cm distal and in the midline to the distal end of the tendon rupture. The distal and proximal Achilles tendon stumps are mobilised. After trying to reduce the gap of the ruptured Achilles tendon, if the gap produced is greater than 6 cm despite maximal plantar flexion of the ankle and traction on the Achilles tendon stumps, the ipsilateral semitendinosus tendon is harvested. The semitendinosus tendon is passed through small incisions in the substance of the proximal stump of the Achilles tendon, and it is sutured to the Achilles tendon. It is then passed beneath the intact skin bridge into the distal incision, and passed from medial to lateral through a transverse tenotomy in the distal stump. With the ankle in maximal plantar flexion, the semitendinosus tendon is sutured to the Achilles tendon at each entry and exit point Conclusion This minimally invasive technique allows reconstruction of the Achilles tendon using the tendon of semitendinosus preserving skin integrity over the site most prone to wound breakdown, and can be especially used to reconstruct the Achilles tendon in the presence of large gap (greater than 6 centimetres.

  19. TWITCH PARAMETERS IN TRANSVERSAL AND LONGITUDINAL BICEPS BRACHII RESPONSE

    Directory of Open Access Journals (Sweden)

    Boštjan Šimunič

    2010-01-01

    Full Text Available Assessment of the contractile properties of skeletal muscles is continuing to be an important issue and a difficult task methodologically. Longitudinal direction of skeletal muscle contraction blurs intrinsic muscle belly contractile properties with many factors. This study evaluates and explains contractile properties such as: delay time (Td, contraction time (Tc, half relaxation time (Tr and maximal amplitude (Dm extracted from twitch transversal response and compare them with torque response. In fifteen healthy males (age 23.7 ± 3.4 years isometric twitch transversal and torque responses were simultaneously recorded during graded electrically elicited contractions in the biceps brachii muscle. The amplitude of electrical stimulation was increased in 5 mA steps from a threshold up to a maximal response. The muscles’ belly transversal response was measured by a high precision mechanical displacement sensor while elbow joint torque was calculated from force readings. Results indicate a parabolic relation between the transversal displacement and the torque Dm. A significantly shorter Tc was found in transversal response without being correlated to torque Tc (r = -0.12; > 0.05. A significant correlation was found between torque Tc and the time occurrence of the second peak in the transversal response (r = 0.83; < 0.001. Electrical stimulation amplitude dependant variation of the Tc was notably different in transversal than in torque response. Td was similar at submaximal and maximal responses but larger in transversal at just above threshold contractions. Tr has a similar linear trend in both responses, however, the magnitude and the slope are much larger in the transversal response. We could conclude that different mechanisms affect longitudinal and transversal twitch skeletal muscle deformations. Contractile properties extracted from the transversal response enable alternative insights into skeletal muscle contraction mechanics.

  20. EFFECT OF THE SHOULDER POSITION ON THE BICEPS BRACHII EMG IN DIFFERENT DUMBBELL CURLS

    Directory of Open Access Journals (Sweden)

    Taian M.M. Vieira

    2009-03-01

    Full Text Available Incline Dumbbell Curl (IDC and Dumbbell Preacher Curl (DPC are two variations of the standard Dumbbell Biceps Curl (DBC, generally applied to optimize biceps brachii contribution for elbow flexion by fixing shoulder at a specific angle. The aim of this study is to identify changes in the neuromuscular activity of biceps brachii long head for IDC, DPC and DBC exercises, by taking into account the changes in load moment arm and muscle length elicited by each dumbbell curl protocol. A single cycle (concentric-eccentric of DBC, IDC and DPC, was applied to 22 subjects using a submaximal load of 40% estimated from an isometric MVC test. The neuromuscular activity of biceps brachii long head was compared by further partitioning each contraction into three phases, according to individual elbow joint range of motion. Although all protocols elicited a considerable level of activation of the biceps brachii muscle (at least 50% of maximum RMS, the contribution of this muscle for elbow flexion/extension varied among exercises. The submaximal elbow flexion (concentric elicited neuro muscular activity up to 95% of the maximum RMS value during the final phase of IDC and DBC and 80% for DPC at the beginning of the movement. All exercises showed significant less muscle activity for the elbow extension (eccentric. The Incline Dumbbell Curl and the classical Dumbbell Biceps Curl resulted in similar patterns of biceps brachii activation for the whole range of motion, whereas Dumbbell Preacher Curl elicited high muscle activation only for a short range of elbow joint angle

  1. Active Achilles tendon kinesitherapy accelerates Achilles tendon repair by promoting neurite regeneration.

    Science.gov (United States)

    Jielile, Jiasharete; Aibai, Minawa; Sabirhazi, Gulnur; Shawutali, Nuerai; Tangkejie, Wulanbai; Badelhan, Aynaz; Nuerduola, Yeermike; Satewalede, Turde; Buranbai, Darehan; Hunapia, Beicen; Jialihasi, Ayidaer; Bai, Jingping; Kizaibek, Murat

    2012-12-15

    Active Achilles tendon kinesitherapy facilitates the functional recovery of a ruptured Achilles tendon. However, protein expression during the healing process remains a controversial issue. New Zealand rabbits, aged 14 weeks, underwent tenotomy followed immediately by Achilles tendon microsurgery to repair the Achilles tendon rupture. The tendon was then immobilized or subjected to postoperative early motion treatment (kinesitherapy). Mass spectrography results showed that after 14 days of motion treatment, 18 protein spots were differentially expressed, among which, 12 were up-regulated, consisting of gelsolin isoform b and neurite growth-related protein collapsing response mediator protein 2. Western blot analysis showed that gelsolin isoform b was up-regulated at days 7-21 of motion treatment. These findings suggest that active Achilles tendon kinesitherapy promotes the neurite regeneration of a ruptured Achilles tendon and gelsolin isoform b can be used as a biomarker for Achilles tendon healing after kinesitherapy.

  2. Active Achilles tendon kinesitherapy accelerates Achilles tendon repair by promoting neurite regeneration☆

    Science.gov (United States)

    Jielile, Jiasharete; Aibai, Minawa; Sabirhazi, Gulnur; Shawutali, Nuerai; Tangkejie, Wulanbai; Badelhan, Aynaz; Nuerduola, Yeermike; Satewalede, Turde; Buranbai, Darehan; Hunapia, Beicen; Jialihasi, Ayidaer; Bai, Jingping; Kizaibek, Murat

    2012-01-01

    Active Achilles tendon kinesitherapy facilitates the functional recovery of a ruptured Achilles tendon. However, protein expression during the healing process remains a controversial issue. New Zealand rabbits, aged 14 weeks, underwent tenotomy followed immediately by Achilles tendon microsurgery to repair the Achilles tendon rupture. The tendon was then immobilized or subjected to postoperative early motion treatment (kinesitherapy). Mass spectrography results showed that after 14 days of motion treatment, 18 protein spots were differentially expressed, among which, 12 were up-regulated, consisting of gelsolin isoform b and neurite growth-related protein collapsing response mediator protein 2. Western blot analysis showed that gelsolin isoform b was up-regulated at days 7–21 of motion treatment. These findings suggest that active Achilles tendon kinesitherapy promotes the neurite regeneration of a ruptured Achilles tendon and gelsolin isoform b can be used as a biomarker for Achilles tendon healing after kinesitherapy. PMID:25317130

  3. Effect of estrogen on tendon collagen synthesis, tendon structural characteristics, and biomechanical properties in postmenopausal women

    DEFF Research Database (Denmark)

    Hansen, Mette; Kongsgaard, Mads; Holm, Lars

    2009-01-01

    and fibril characteristics were determined by MRI and transmission electron microscopy, whereas tendon biomechanical properties were measured during isometric maximal voluntary contraction by ultrasound recording. Tendon FSR was markedly higher in ERT-users (P

  4. Genetic instability in nerve sheath cell tumors

    DEFF Research Database (Denmark)

    Rogatto, Silvia Regina; Casartelli, Cacilda; Rainho, Claudia Aparecida

    1995-01-01

    After in vitro culture, we analyzed cytogenetically four acoustic nerve neurinomas, one intraspinal neurinoma and one neurofibroma obtainedfrom unrelated patients. Monosomy of chromosomes 22 and 16 was an abnormality common to all cases, followed in frequency by loss of chromosomes 18 (three cases...... by the presence of polyploid cells with inconsistent abnormalities, endoreduplications and telomeric associations resulting in dicentric chromosomes. It is probable that these cytogenetic abnormalities represent some kind of evolutionary advantage for the in vitro progression of nerve sheath tumors....

  5. Tendon Force Transmission at the Nanoscale

    DEFF Research Database (Denmark)

    Svensson, René

    2013-01-01

    of connective tissue function that are poorly understood. One such aspect is the microscopic mechanisms of force transmission through tendons over macroscopic distances. Force transmission is at the heart of tendon function, but the large range of scales in the hierarchical structure of tendons has made...... it difficult to tackle. The tendon hierarchy ranges from molecules (2 nm) over fibrils (200 nm), fibers (2 μm) and fascicles (200 μm) to tendons (10 mm), and to derive the mechanisms of force transmission it is necessary to know the mechanical behavior at each hierarchical level. The aim of the present work...... was to elucidate the mechanisms of force transmission in tendons primarily by investigating the mechanical behavior at the hierarchical level of collagen fibrils. To do so we have developed an atomic force microscopy (AFM) method for tensile testing of native collagen fibrils. The thesis contains five papers...

  6. Achilles tendon rupture in badminton.

    Science.gov (United States)

    Kaalund, S; Lass, P; Høgsaa, B; Nøhr, M

    1989-01-01

    The typical badminton player with an Achilles tendon rupture is 36 years old and, despite limbering up, is injured at the rear line in a sudden forward movement. He resumes work within three months and has a slight lack of dorsiflexion in the ankle as the main complication. Most patients resume badminton within one year, but some finish their sports career, mainly due to fear of a new injury. The investigation discusses predisposing factors and prophylactic measures. PMID:2605439

  7. The roentgenographic findings of achilles tendon rupture

    Energy Technology Data Exchange (ETDEWEB)

    Seouk, Kang Hyo; Keun, Rho Yong [Shilla General Hospital, Seoul (Korea, Republic of)

    1999-03-01

    To evaluate the diagnostic value of a lateral view of the ankles in Achilles tendon rupture. We performed a retrospective analysis of the roentgenographic findings of 15 patients with surgically proven Achilles tendon rupture. Four groups of 15 patients(normal, ankle sprain, medial lateral malleolar fracture, and calcaneal fracture) were analysed as reference groups. Plain radiographs were reviewed with regard to Kager's triangle, Arner's sign, Toygar's angle, ill defined radiolucent shadow through the Achilles tendon, sharpness of the anterior margin of Achilles tendon, and meniscoid smooth margin of the posterior skin surface of the ankle. Kager's triangle was deformed and disappeared after rupture of the Achilles tendon in nine patients(60%) with operative verification of the rupture, six patients(40%) had a positive Arner's sign, while none had a diminished Toygars angle. In 13 patients(87%) with a ruptured Achilles tendon, the thickness of this was nonuniform compared with the reference group. The anterior margin of the Achilles tendon became serrated and indistinct in 14 patients(93%) in whom this was ruptured. An abnormal ill defined radiolucent shadow through the Achilles tendon was noted in nine patient(60%), and nonparallelism between the anterior margin of the Achilles tendon and posterior skin surface of the ankle was detected in 11 patients(73%). The posterior skin surface of the ankle had a nodular surface margin in 13 patients(87%). A deformed Kager's triangle and Achilles tendon, and an abnormal ill defined radiolucent shadow through the Achilles tendon in a lateral view of the ankles are important findings for the diagnesis of in diagnosing achilles tendon rupture.

  8. The roentgenographic findings of achilles tendon rupture

    International Nuclear Information System (INIS)

    Seouk, Kang Hyo; Keun, Rho Yong

    1999-01-01

    To evaluate the diagnostic value of a lateral view of the ankles in Achilles tendon rupture. We performed a retrospective analysis of the roentgenographic findings of 15 patients with surgically proven Achilles tendon rupture. Four groups of 15 patients(normal, ankle sprain, medial lateral malleolar fracture, and calcaneal fracture) were analysed as reference groups. Plain radiographs were reviewed with regard to Kager's triangle, Arner's sign, Toygar's angle, ill defined radiolucent shadow through the Achilles tendon, sharpness of the anterior margin of Achilles tendon, and meniscoid smooth margin of the posterior skin surface of the ankle. Kager's triangle was deformed and disappeared after rupture of the Achilles tendon in nine patients(60%) with operative verification of the rupture, six patients(40%) had a positive Arner's sign, while none had a diminished Toygars angle. In 13 patients(87%) with a ruptured Achilles tendon, the thickness of this was nonuniform compared with the reference group. The anterior margin of the Achilles tendon became serrated and indistinct in 14 patients(93%) in whom this was ruptured. An abnormal ill defined radiolucent shadow through the Achilles tendon was noted in nine patient(60%), and nonparallelism between the anterior margin of the Achilles tendon and posterior skin surface of the ankle was detected in 11 patients(73%). The posterior skin surface of the ankle had a nodular surface margin in 13 patients(87%). A deformed Kager's triangle and Achilles tendon, and an abnormal ill defined radiolucent shadow through the Achilles tendon in a lateral view of the ankles are important findings for the diagnesis of in diagnosing achilles tendon rupture

  9. Radio frequency sheaths in an oblique magnetic field

    International Nuclear Information System (INIS)

    Myra, J. R.; D'Ippolito, D. A.

    2015-01-01

    The physics of radio-frequency (rf) sheaths near a conducting surface is studied for plasmas immersed in a magnetic field that makes an oblique angle θ with the surface. A set of one-dimensional equations is developed that describes the dynamics of the time-dependent magnetic presheath and non-neutral Debye sheath. The model employs Maxwell-Boltzmann electrons, and the magnetization and mobility of the ions is determined by the magnetic field strength, and wave frequency, respectively. The angle θ, assumed to be large enough to insure an electron-poor sheath, is otherwise arbitrary. Concentrating on the ion-cyclotron range of frequencies, the equations are solved numerically to obtain the rectified (dc) voltage, the rf voltage across the sheath, and the rf current flowing through the sheath. As an application of this model, the sheath voltage-current relation is used to obtain the rf sheath impedance, which in turn gives an rf sheath boundary condition for the electric field at the sheath-plasma interface that can be used in rf wave codes. In general, the impedance has both resistive and capacitive contributions, and generalizes previous sheath boundary condition models. The resistive part contributes to parasitic power dissipation at the wall

  10. Optic Nerve Sheath Mechanics in VIIP Syndrome

    Science.gov (United States)

    Raykin, Julia; Forte, Taylor E.; Wang, Roy; Feola, Andrew; Samuels, Brian; Myers, Jerry; Nelson, Emily; Gleason, Rudy; Ethier, C. Ross

    2016-01-01

    Visual Impairment Intracranial Pressure (VIIP) syndrome is a major concern in current space medicine research. While the exact pathology of VIIP is not yet known, it is hypothesized that the microgravity-induced cephalad fluid shift increases intracranial pressure (ICP) and drives remodeling of the optic nerve sheath. To investigate this possibility, we are culturing optic nerve sheath dura mater samples under different pressures and investigating changes in tissue composition. To interpret results from this work, it is essential to first understand the biomechanical response of the optic nerve sheath dura mater to loading. Here, we investigated the effects of mechanical loading on the porcine optic nerve sheath.Porcine optic nerves (number: 6) were obtained immediately after death from a local abattoir. The optic nerve sheath (dura mater) was isolated from the optic nerve proper, leaving a hollow cylinder of connective tissue that was used for biomechanical characterization. We developed a custom mechanical testing system that allowed for unconfined lengthening, twisting, and circumferential distension of the dura mater during inflation and under fixed axial loading. To determine the effects of variations in ICP, the sample was inflated (0-60 millimeters Hg) and circumferential distension was simultaneously recorded. These tests were performed under variable axial loads (0.6 grams - 5.6 grams at increments of 1 gram) by attaching different weights to one end of the dura mater. Results and Conclusions: The samples demonstrated nonlinear behavior, similar to other soft connective tissue (Figure 1). Large increases in diameter were observed at lower transmural pressures (approximately 0 to 5 millimeters Hg), whereas only small diameter changes were observed at higher pressures. Particularly interesting was the existence of a cross-over point at a pressure of approximately 11 millimeters Hg. At this pressure, the same diameter is obtained for all axial loads applied

  11. Biology and augmentation of tendon-bone insertion repair

    OpenAIRE

    Lui, PPY; Zhang, P; Chan, KM; Qin, L

    2010-01-01

    Abstract Surgical reattachment of tendon and bone such as in rotator cuff repair, patellar-patella tendon repair and anterior cruciate ligament (ACL) reconstruction often fails due to the failure of regeneration of the specialized tissue ("enthesis") which connects tendon to bone. Tendon-to-bone healing taking place between inhomogenous tissues is a slow process compared to healing within homogenous tissue, such as tendon to tendon or bone to bone healing. Therefore special attention must be ...

  12. Sheath insulator final test report, TFE Verification Program

    International Nuclear Information System (INIS)

    1994-07-01

    The sheath insulator in a thermionic cell has two functions. First, the sheath insulator must electrically isolate the collector form the outer containment sheath tube that is in contact with the reactor liquid metal coolant. Second, The sheath insulator must provide for high uniform thermal conductance between the collector and the reactor coolant to remove away waste heat. The goals of the sheath insulator test program were to demonstrate that suitable ceramic materials and fabrication processes were available, and to validate the performance of the sheath insulator for TFE-VP requirements. This report discusses the objectives of the test program, fabrication development, ex-reactor test program, in-reactor test program, and the insulator seal specifications

  13. Sheath insulator final test report, TFE Verification Program

    Energy Technology Data Exchange (ETDEWEB)

    1994-07-01

    The sheath insulator in a thermionic cell has two functions. First, the sheath insulator must electrically isolate the collector form the outer containment sheath tube that is in contact with the reactor liquid metal coolant. Second, The sheath insulator must provide for high uniform thermal conductance between the collector and the reactor coolant to remove away waste heat. The goals of the sheath insulator test program were to demonstrate that suitable ceramic materials and fabrication processes were available, and to validate the performance of the sheath insulator for TFE-VP requirements. This report discusses the objectives of the test program, fabrication development, ex-reactor test program, in-reactor test program, and the insulator seal specifications.

  14. MRI findings of achilles tendon rupture

    International Nuclear Information System (INIS)

    Zhang Xuezhe

    2009-01-01

    Objective: To evaluate the MRI findings of achilles tendon rupture. Methods: The MRI data of 7 patients with achilles tendon rupture were retrospectively analysed. All 7 patients were male with the age ranging from 34 to 71 years. Routine MR scanning was performed in axial and sagittal planes, including T 1 WI, T 2 WI and a fat suppression MRI (SPIR). Results: Among 7 patients, complete achilles tendon rupture was seen in 6 cases, partial achilles tendon rupture 1 case. The site of tendon disruption were 2.6-11.0 cm( mean 5.4 cm) proximal to the insertion in the calcaneus. The MRI findings of a partial or complete rupture of the achilles tendon included enlarged and thickened achilles tendon (7 cases), wavy lax achilles tendon (2 cases), discontinuity of some or all of its fibers and intratendinous regions of increased signal intensity (7 cases). In the cases of complete tendon rupture, the size of the tendinous gap varied from 3.0-8.0 mm, which was filled with blood and appeared as edema of increase signal intensity on T 2 WI and SPIR. In all 7 patients, MR scanning showed medium signal intensity (7 cases) on T 1 WI, or medium signal intensity (1 cases), medium-high signal intensity (3 cases ), high signal intensity (3 cases) on T 2 WI, and medium-high signal intensity (2 cases), high signal intensity (5 cases) on fat suppression MRI. The preachilles fat pad showed obscure in 6 cases of complete achilles tendon rupture. Conclusion: MRI is an excellent method for revealing achilles tendon rupture and confirming the diagnosis. (authors)

  15. Nonoperative treatment of distal biceps brachii musculotendinous partial rupture: a report of two cases.

    Science.gov (United States)

    López-Zabala, I; Fernández-Valencia, J A

    2013-01-01

    Musculotendinous ruptures of the distal biceps brachii are extremely rare injuries whose clinical presentation is similar to distal biceps avulsion. We describe two cases of patients who suffered a distal biceps brachii musculotendinous partial rupture. The first patient was playing soccer as goalkeeper and experienced sudden pain while throwing the ball overhead with his left arm. The second patient experienced sudden pain while weightlifting with his right arm. The mechanism of injury was the same in the two cases, as both involved glenohumeral elevation with elbow extension and forearm supination. Neither of these two patients underwent surgical repair or rehabilitation, and both had perfect scores of 100 on the Mayo Clinic Performance Index for the Elbow at one-year followup.

  16. Sheath heating in low-pressure capacitive radio frequency discharges

    International Nuclear Information System (INIS)

    Wood, B.P.

    1991-01-01

    Capacitively coupled, parallel plate, r.f. discharges are commonly used for materials processing. The electrons in such a discharge gain and lose energy by reflection from the oscillating sheaths which form at the electrodes. Previous models of the electron heating by this mechanism have assumed that the sheath motion is slow compared to the electron thermal velocity, so that the electron energy change from each reflection is small. Here, the heating rate, density, and sheath width relations are derived analytically in the limit of very fast sheath motion. Numerical results are presented spanning the slow and fast limits. Results from particle-in-cell simulations show that in the large-energy-change regime, an electron beam is produced on each sheath expansion. At low pressure, this beam can traverse the plasma and interact with the sheath at the opposite electrode, producing a beam energy and density dependence on the length of the discharge. The beam produces a time and space varying warm tail on the electron energy distribution. Two revised heating models are derived, assuming power-law and two-temperature electron energy distributions, with temporal variation in electron temperature. These revised models yield new predictions for the variation of the power, density, and sheath thickness with applied r.f. voltage. These predictions are compared with simulation results and laboratory experiment. The electron sheath motion is investigated experimentally by observing the signal on a floating probe in the sheath region. This is compared to the signal product by a non-linear circuit model which accounts for the perturbation of the sheath potential by the probe and includes various forms of sheath motion. The experimental observations are consistent with the analytical predictions. Experimental observations of plasma-sheath resonance oscillations are presented which agree with analytical predictions

  17. Nondestructive testing of metallic sheath for internally cooled superconductor

    International Nuclear Information System (INIS)

    McClung, R.W.; Cook, K.V.; Dodd, C.V.; Smith, J.H.

    1983-01-01

    For quality assurance in the Oak Ridge National Laboratory Large Coil Program, we developed ultrasonic and eddy-current techniques to examine the JBK-75 alloy sheath for superconducting cable for a large magnet. Ultrasound was used to examine the strip before forming into the sheath, and eddy currents were used to examine the seam weld after the sheath had been formed around the cable

  18. The Effect of Sodium Hyaluronate on Ligamentation and Biomechanical Property of Tendon in Repair of Achilles Tendon Defect with Polyethylene Terephthalate Artificial Ligament: A Rabbit Tendon Repair Model

    OpenAIRE

    Li, Shengkun; Ma, Kui; Li, Hong; Jiang, Jia; Chen, Shiyi

    2016-01-01

    The Achilles tendon is the most common ruptured tendon of human body. Reconstruction with polyethylene terephthalate (PET) artificial ligament is recommended in some serious cases. Sodium hyaluronate (HA) is beneficial for the healing of tendon injuries. We aimed to determine the effect of sodium hyaluronate in repair of Achilles tendon defect with PET artificial ligament in an animal tendon repair model. Sixteen New Zealand White rabbits were divided into two groups. Eight rabbits repaired w...

  19. Mechanical Properties of Human Patellar Tendon at the Hierarchical levels of Tendon and Fibril

    DEFF Research Database (Denmark)

    Svensson, Rene Brüggebusch; Hansen, Philip; Hassenkam, Tue

    2012-01-01

    Tendons are strong hierarchical structures, but how tensile forces are transmitted between different levels remains incompletely understood. Collagen fibrils are thought to be primary determinants of whole tendon properties, and therefore we hypothesized that the whole human patellar tendon and its...... distinct collagen fibrils would display similar mechanical properties. Human patellar tendons (n=5) were mechanically tested in vivo by ultrasonography. Biopsies were obtained from each tendon and individual collagen fibrils were dissected and tested mechanically by atomic force microscopy. The Young...... that of tendon supports that fibrillar rather than interfibrillar properties govern sub-failure tendon response, making the fibrillar level a meaningful target of intervention. The lower modulus found in vitro suggests a possible adverse effect of removing the tissue from its natural environment. In addition...

  20. Annihilation model of the Tormac sheath

    International Nuclear Information System (INIS)

    Hammer, J.H.

    1979-02-01

    A one-dimensional, steady state fluid model is developed to describe the boundary layer between plasma and magnetic field that occurs in the Tormac sheath. Similar systems which may be treatable by the same model are tokamaks with divertors and reversed field mirrors. The model includes transport across the magnetic field as well as mirror losses along the field, the latter being represented as annihilation terms in the one-dimensional equations. The model equations are derived from the two-dimensional, time dependent hierarchy of equations generated by taking velocity moments of the kinetic equation including collisions

  1. ICRF antenna Faraday shield plasma sheath model

    International Nuclear Information System (INIS)

    Whealton, J.H.; Ryan, P.M.; Raridon, R.J.

    1990-01-01

    A two-dimensional nonlinear formulation that explicitly considers the plasma edge near a Faraday shield in a self-consistent manner is used in the modeling of the ion motion for a Faraday shield concept and model suggested by Perkins. Two models are considered that may provide significant insight into the generation of impurities for ion cyclotron resonance heating (ICRH) antennas. In one of these models a significant sheath periodically forms next to the Faraday screen, with ion acoustic waves heating the ions in the plasma. (orig.)

  2. Simulation of tendon energy storage in pedaling

    DEFF Research Database (Denmark)

    Rasmussen, John; Damsgaard, Michael; Christensen, Søren Tørholm

    2001-01-01

    The role of elastic energy stored in tendons during pedaling is investigated by means of numerical simulation using the AnyBody body modeling system. The loss of metabolic energy due to tendon elasticity is computed and compared to the mechanical work involved in the process. The AnyBody simulati...

  3. Rupture of Achilles Tendon : Usefulness of Ultrasonography

    International Nuclear Information System (INIS)

    Kim, Nam Hyeon; Ki, Won Woo; Yoon, Kwon Ha; Kim, Song Mun; Shin, Myeong Jin; Kwon, Soon Tae

    1996-01-01

    To differentiate a complete rupture of Achilles tendon from an incomplete one which is important because its treatment is quite different. And it is necessary to know the exact site of the rupture preoperatively. Fifteen cases of fourteen patients which were diagnosed as Achilles tendon rupture by ultrasonography and surgery were reviewed. We compared sonographic rupture site with surgical findings. Ultrasonographic criteria for differentiation of complete and incomplete rupture was defined as follows : the discreteness, which means the proximal intervening hypoechogenicity to the interface echogenicity of distal margin of ruptured tendon : the slant sign, which represents the interface of ruptured distal margin which was seen over the 3/4 of the thickness of the tendon without intervening low echogeneicity : the invagination sign, which means the echogenic invagination from Kager triangle into posterior aspect of Achilles tendon over the half thickness of the tendon. The sites of complete tendon rupture were exactly corresponded to surgical finding in four cases of ten complete ruptures. And the discrepancy between sonographic and surgical findings in the site of complete rupture was 1.2 ± 0.4 cm in six cases. Three of ten complete ruptures showed the discreteness sign, all of ten showed the slant sign and two of ten showed the invagination sign. It is helpful to differentiate a complete from incomplete rupture of the Achilles tendon and to localize the site of the complete rupture with the ultrasonographic evaluation

  4. Measuring Regional Changes in Damaged Tendon

    Science.gov (United States)

    Frisch, Catherine Kayt Vincent

    Mechanical properties of tendon predict tendon health and function, but measuring these properties in vivo is difficult. An ultrasound-based (US) analysis technique called acoustoelastography (AE) uses load-dependent changes in the reflected US signal to estimate tissue stiffness non-invasively. This thesis explores whether AE can provide information about stiffness alteration resulting from tendon tears both ex vivo and in vivo. An ex vivo ovine infraspinatus tendon model suggests that the relative load transmitted by the different tendon layers transmit different fractions of the load and that ultrasound echo intensity change during cyclic loading decreases, becoming less consistent once the tendon is torn. An in vivo human tibialis anterior tendon model using electrically stimulated twitch contractions investigated the feasibility of measuring the effect in vivo. Four of the five subjects showed the expected change and that the muscle contraction times calculated using the average grayscale echo intensity change compared favorably with the times calculated based on the force data. Finally an AE pilot study with patients who had rotator cuff tendon tears found that controlling the applied load and the US view of the system will be crucial to a successful in vivo study.

  5. Bilateral synchronous rupture of the quadriceps tendon.

    LENUS (Irish Health Repository)

    Ellanti, P

    2012-09-01

    Bilateral simultaneous rupture of the quadriceps tendon is a rare entity. They are often associated with degenerative changes of the tendons and predisposing conditions such as diabetes or excessive steroid use. They most commonly tend to occur in patients of 40 years of age or older.

  6. The characteristics of RF modulated plasma boundary sheaths: An analysis of the standard sheath model

    Science.gov (United States)

    Naggary, Schabnam; Brinkmann, Ralf Peter

    2015-09-01

    The characteristics of radio frequency (RF) modulated plasma boundary sheaths are studied on the basis of the so-called ``standard sheath model.'' This model assumes that the applied radio frequency ωRF is larger than the plasma frequency of the ions but smaller than that of the electrons. It comprises a phase-averaged ion model - consisting of an equation of continuity (with ionization neglected) and an equation of motion (with collisional ion-neutral interaction taken into account) - a phase-resolved electron model - consisting of an equation of continuity and the assumption of Boltzmann equilibrium -, and Poisson's equation for the electrical field. Previous investigations have studied the standard sheath model under additional approximations, most notably the assumption of a step-like electron front. This contribution presents an investigation and parameter study of the standard sheath model which avoids any further assumptions. The resulting density profiles and overall charge-voltage characteristics are compared with those of the step-model based theories. The authors gratefully acknowledge Efe Kemaneci for helpful comments and fruitful discussions.

  7. Thompson Test in Achilles Tendon Rupture

    Directory of Open Access Journals (Sweden)

    Spencer Albertson

    2016-07-01

    Full Text Available HPI: A 26-year old male presented to the emergency department after experiencing the acute onset of left ankle pain while playing basketball. Upon jumping, he felt a “pop” in his left posterior ankle, followed by pain and difficulty ambulating. His exam was notable for a defect at the left Achilles tendon on palpation. The practitioner performed a Thompson test, which was positive (abnormal on the left. Significant Findings: The left Achilles tendon had a defect on palpation, while the right Achilles tendon was intact. When squeezing the right (unaffected calf, the ankle spontaneously plantar flexed, indicating a negative (normal Thompson test. Upon squeeze of the left (affected calf, the ankle did not plantar flex, signifying a positive (abnormal Thompson test. The diagnosis of left Achilles tendon rupture was confirmed intraoperatively one week later. Discussion: The Achilles tendon (also: calcaneal tendon or heel cord is derived from the medial and lateral heads of the gastrocnemius muscle, as well as the soleus muscle. Rupture of the Achilles tendon most commonly occurs in the distal tendon, approximately 2-6 cm from its attachment to the calcaneal tuberosity, in an area of hypovascularity known as the “watershed” or “critical” zone.1-3 The Thompson test (also: Simmonds-Thompson test, described by Simmonds in 1957 and Thompson in 1962, is done while the patient is in the prone position, with feet hanging over the end of a table/gurney, or with the patient kneeling on a stool or chair.4-5 Squeezing the calf of an unaffected limb will cause the ankle to plantar flex, but squeezing the calf of a limb with an Achilles tendon rupture will cause no motion. The sensitivity of the Thompson’s test for the diagnosis of a complete Achilles tendon rupture is 96-100% and the specificity is 93-100%, but data is limited.6-8

  8. THE ROLE OF DETRAINING IN TENDON MECHANOBIOLOGY

    Directory of Open Access Journals (Sweden)

    Antonio eFrizziero

    2016-02-01

    Full Text Available Introduction: Several conditions such as training, aging, estrogen deficiency and drugs could affect the biological and anatomo-physiological characteristics of the tendon. Additionally, recent preclinical and clinical studies examined the effect of detraining on tendon, showing alterations in its structure and morphology and in tenocyte mechanobiology. However, there is a paucity of data examining the impact that cessation of training may have on tendon. In practice, we do not fully understand how tendons respond to a period of training followed by sudden detraining. Therefore, within this review, we summarize the studies where tendon detraining was examined.Materials and methods: A descriptive systematic literature review was conducted by searching three databases (PubMed, Scopus and Web of Knowledge on tendon detraining. Original articles in English from 2000 to 2015 were included. In addition, the search was extended to the reference lists of the selected articles. A public reference manager (www.mendeley.com was used to delete duplicate articles.Results: An initial literature search yielded 134 references (www.pubmed.org: 53; www.scopus.com: 11; www.webofknowledge.com: 70. 15 publications were extracted based on the title for further analysis by two independent reviewers. Abstracts and whole articles were then reviewed to detect if they met inclusion criteria.Conclusions: The revised literature comprised 4 clinical studies and an in vitro and three in vivo reports. Overall, the results showed that tendon structure and properties after detraining are compromised, with an alteration in the tissue structural organization and mechanical properties. Clinical studies usually showed a lesser extent of tendon alterations, probably because preclinical studies permit an in-depth evaluation of tendon modifications, which is hard to perform in human subjects. In conclusion, after a period of sudden detraining (e.g. after an injury, physical activity

  9. The plasma-sheath boundary region

    International Nuclear Information System (INIS)

    Franklin, R N

    2003-01-01

    In this review an attempt is made to give a broad coverage of the problem of joining plasma and sheath over a wide range of physical conditions. We go back to the earliest works quoting them, where appropriate, to understand what those who introduced the various terms associated with the structure of the plasma-sheath had in mind. We try to bring out the essence of the insights that have been gained subsequently, by quoting from the literature selectively, indicating how misunderstandings have arisen. In order to make it accessible to the generality of those currently working in low temperature plasmas we have sought to avoid mathematical complexity but retain physical insight, quoting from published work where appropriate. Nevertheless, in clarifying my own ideas I have found it necessary to do additional original work in order to give a consistent picture. In this way I have sought to bring together work in the late 1920s, the 1960s, and now mindful of the commercial importance of plasma processing, work over the past 15 years that adds to the general understanding. (topical review)

  10. Serial superficial digital flexor tendon biopsies for diagnosing and monitoring collagenase-induced tendonitis in horses

    Directory of Open Access Journals (Sweden)

    José C. de Lacerda Neto

    2013-06-01

    Full Text Available The purpose of this investigation was to demonstrate the feasibility of a biopsy technique by performing serial evaluations of tissue samples of the forelimb superficial digital flexor tendon (SDFT in healthy horses and in horses subjected to superficial digital flexor tendonitis induction. Eight adult horses were evaluated in two different phases (P, control (P1 and tendonitis-induced (P2. At P1, the horses were subjected to five SDFT biopsies of the left forelimb, with 24 hours (h of interval. Clinical and ultrasonographic (US examinations were performed immediately before the tendonitis induction, 24 and 48 h after the procedure. The biopsied tendon tissues were analyzed through histology. P2 evaluations were carried out three months later, when the same horses were subjected to tendonitis induction by injection of bacterial collagenase into the right forelimb SDFT. P2 clinical and US evaluations, and SDFT biopsies were performed before, and after injury induction at the following time intervals: after 24, 48, 72 and 96 h, and after 15, 30, 60, 90, 120 and 150 days. The biopsy technique has proven to be easy and quick to perform and yielded good tendon samples for histological evaluation. At P1 the horses did not show signs of localised inflammation, pain or lameness, neither SDFT US alterations after biopsies, showing that the biopsy procedure per se did not risk tendon integrity. Therefore, this procedure is feasible for routine tendon histological evaluations. The P2 findings demonstrate a relation between the US and histology evaluations concerning induced tendonitis evolution. However, the clinical signs of tendonitis poorly reflected the microscopic tissue condition, indicating that clinical presentation is not a reliable parameter for monitoring injury development. The presented method of biopsying SDFT tissue in horses enables the serial collection of material for histological analysis causing no clinical signs and tendon damage seen

  11. Achilles tendon: US diagnosis of pathologic conditions. Work in progress

    International Nuclear Information System (INIS)

    Blei, C.L.; Nirschl, R.P.; Grant, E.G.

    1986-01-01

    Twenty-three patients were prospectively examined with ultra-sound (US) for acute or recurrent Achilles tendon symptoms. Three types of pathologic conditions of the Achilles tendon were found: tendinitis/tenosynovitis, acute tendon trauma, and postoperative changes. US appears to enable differentiation of these conditions and to contribute to the diagnosis of a broad range of Achilles tendon disorders

  12. Achilles tendon: US diagnosis of pathologic conditions. Work in progress

    Energy Technology Data Exchange (ETDEWEB)

    Blei, C.L.; Nirschl, R.P.; Grant, E.G.

    1986-06-01

    Twenty-three patients were prospectively examined with ultra-sound (US) for acute or recurrent Achilles tendon symptoms. Three types of pathologic conditions of the Achilles tendon were found: tendinitis/tenosynovitis, acute tendon trauma, and postoperative changes. US appears to enable differentiation of these conditions and to contribute to the diagnosis of a broad range of Achilles tendon disorders.

  13. Micromechanical properties and collagen composition of ruptured human achilles tendon

    DEFF Research Database (Denmark)

    Hansen, Philip; Kovanen, Vuokko; Hölmich, Per

    2013-01-01

    The Achilles tendon is one of the strongest tendons in the human body, and yet it frequently ruptures, which is a substantial clinical problem. However, the cause of ruptures remains elusive.......The Achilles tendon is one of the strongest tendons in the human body, and yet it frequently ruptures, which is a substantial clinical problem. However, the cause of ruptures remains elusive....

  14. Region-specific mechanical properties of the human patella tendon

    DEFF Research Database (Denmark)

    Haraldsson, B T; Aagaard, P; Krogsgaard, M

    2004-01-01

    The present study investigated the mechanical properties of tendon fascicles from the anterior and posterior human patellar tendon. Collagen fascicles from the anterior and posterior human patellar tendon in healthy young men (mean +/- SD, 29.0 +/- 4.6 yr, n = 6) were tested in a mechanical rig...... portion of the tendon, indicating region-specific material properties....

  15. Embedded cladding surface thermocouples on Zircaloy-sheathed heater rods

    International Nuclear Information System (INIS)

    Wilkins, S.C.

    1977-06-01

    Titanium-sheathed Type K thermocouples embedded in the cladding wall of zircaloy-sheathed heater rods are described. These thermocouples constitute part of a program intended to characterize the uncertainty of measurements made by surface-mounted cladding thermocouples on nuclear fuel rods. Fabrication and installation detail, and laboratory testing of sample thermocouple installations are included

  16. Sheath structure transition controlled by secondary electron emission

    Science.gov (United States)

    Schweigert, I. V.; Langendorf, S. J.; Walker, M. L. R.; Keidar, M.

    2015-04-01

    In particle-in-cell Monte Carlo collision (PIC MCC) simulations and in an experiment we study sheath formation over an emissive floating Al2O3 plate in a direct current discharge plasma at argon gas pressure 10-4 Torr. The discharge glow is maintained by the beam electrons emitted from a negatively biased hot cathode. We observe three types of sheaths near the floating emissive plate and the transition between them is driven by changing the negative bias. The Debye sheath appears at lower voltages, when secondary electron emission is negligible. With increasing applied voltage, secondary electron emission switches on and a first transition to a new sheath type, beam electron emission (BEE), takes place. For the first time we find this specific regime of sheath operation near the floating emissive surface. In this regime, the potential drop over the plate sheath is about four times larger than the temperature of plasma electrons. The virtual cathode appears near the emissive plate and its modification helps to maintain the BEE regime within some voltage range. Further increase of the applied voltage U initiates the second smooth transition to the plasma electron emission sheath regime and the ratio Δφs/Te tends to unity with increasing U. The oscillatory behavior of the emissive sheath is analyzed in PIC MCC simulations. A plasmoid of slow electrons is formed near the plate and transported to the bulk plasma periodically with a frequency of about 25 kHz.

  17. Electrospinning jet behaviors under the constraints of a sheath gas

    Directory of Open Access Journals (Sweden)

    Yang Zhao

    2016-11-01

    Full Text Available Increasing the ejection efficiency and uniformity of nanofibers is the key to applications of electrospinning technology. In this work, a novel electrospinning spinneret with a sheath gas passageway is designed. The frictional resistance that stems from the sheath gas provides additional stretching and restriction forces on the jet. The sheath gas also reduces interference and enhances the stability of the charged jet. A bead-on-strain simulation model is built up to determine the constraint effects of the sheath gas. Simulation results show that the sheath gas decreases the motion area and increases the stretching ratio of the liquid jet. The stretching force from the sheath gas decreases the diameter and increases the uniformity of the nanofiber. As the gas pressure increases from 0 kPa to 50 kPa, the critical voltage of the jet ejection decreases from 8.4 kV to 2.5 kV, the diameter of the nanofiber deposition zone decreases from 40 cm to 10 cm, and the diameter of the nanofibers decreases from 557.97 nm to 277.73 nm. The uniformity of nanofibers can be improved significantly using a sheath gas. The sheath gas contributes to the rapid deposition of a uniform nanofibrous membrane and the industrial applications of electrospinning.

  18. Significance of rice sheath photosynthesis: Yield determination by ...

    African Journals Online (AJOL)

    Using high-yielding hybrid rice Liangyopeijiu (LYP9), its male parent 9311 and hybrid rice Shanyou 63 (SY63) as the experimental materials, the photosynthesis of rice sheath was studied by 14C radio-autography. The results showed that rice sheath could trap sunlight and produce photosynthates, and these ...

  19. Anode Sheath Switching in a Carbon Nanotube Arc Plasma

    International Nuclear Information System (INIS)

    Fetterman, Abe; Raitses, Yevgeny; Keidar, Michael

    2008-01-01

    The anode ablation rate is investigated as a function of anode diameter for a carbon nanotube arc plasma. It is found that anomalously high ablation occurs for small anode diameters. This result is explained by the formation of a positive anode sheath. The increased ablation rate due to this positive anode sheath could imply greater production rate for carbon nanotubes.

  20. High-field MR imaging of the tendons

    International Nuclear Information System (INIS)

    Beltran, J.; Burk, J.M.; Herman, L.J.; Mosure, J.C.

    1987-01-01

    MR imaging was used to investigate normal anatomy and pathologic conditions of the tendons. Tendons of experimental animals, cadaver joints, normal volunteers, and patients with suspected tendon pathology were studied. Tendon anatomy is easily identified because of the hypointensity of the tendons contrasting with the hyperintendensity of the surrounding fat. Pathologic conditions including posttraumatic and postsurgical tendon rupture, peritendinous scarring, tendinitis, and tenosynovitis are well seen with MR imaging. A detailed study of normal and abnormal tendon anatomy of the finger, wrist, shoulder, knee, and ankle is displayed, including MR images, gross specimens, and line drawings

  1. Effect of cooling on thixotropic position-sense error in human biceps muscle.

    Science.gov (United States)

    Sekihara, Chikara; Izumizaki, Masahiko; Yasuda, Tomohiro; Nakajima, Takayuki; Atsumi, Takashi; Homma, Ikuo

    2007-06-01

    Muscle temperature affects muscle thixotropy. However, it is unclear whether changes in muscle temperature affect thixotropic position-sense errors. We studied the effect of cooling on thixotropic position-sense errors induced by short-length muscle contraction (hold-short conditioning) in the biceps of 12 healthy men. After hold-short conditioning of the right biceps muscle in a cooled (5.0 degrees C) or control (36.5 degrees C) environment, subjects perceived greater extension of the conditioned forearm at 5.0 degrees C. The angle differences between the two forearms following hold-short conditioning of the right biceps muscle in normal or cooled conditions were significantly different (-3.335 +/- 1.680 degrees at 36.5 degrees C vs. -5.317 +/- 1.096 degrees at 5.0 degrees C; P=0.043). Induction of a tonic vibration reflex in the biceps muscle elicited involuntary forearm elevation, and the angular velocities of the elevation differed significantly between arms conditioned in normal and cooled environments (1.583 +/- 0.326 degrees /s at 36.5 degrees C vs. 3.100 +/- 0.555 degrees /s at 5.0 degrees C, P=0.0039). Thus, a cooled environment impairs a muscle's ability to provide positional information, potentially leading to poor muscle performance.

  2. Changes in recruitment order of motor units in the human biceps muscle

    NARCIS (Netherlands)

    Haar Romenij, ter B.M.; Denier van der Gon, J.J.; Gielen, C.C.A.M.

    1982-01-01

    Changes in recruitment threshold of individual motor units of the human biceps (caput longum), a multifunctional muscle, were investigated during different tasks, i.e., isometric flexion of the elbow, isometric supination of the forearm, and isometric exorotation of the humerus of the 110° flexed

  3. Supernumerary head of biceps brachii and branching pattern of the musculocutaneous nerve

    Directory of Open Access Journals (Sweden)

    Mohan Basavaraj Angadi

    2016-01-01

    Full Text Available During routine dissection by medical undergraduates, third head of the biceps brachii muscle was found on the left side of a 75-year-old male cadaver in a total of 48 arms dissected in Department of Anatomy Armed Forces Medical College, Pune. Biceps brachii is a muscle of arm having two heads hence the name. The most frequent variation of the muscle is in the number of heads with a prevalence range of 9.1-22.9%. The origin of the supernumerary head in this case was from the humerus, between the insertion of the coracobrachialis and the upper part of the origin of the brachialis, and also from the medial intermuscular septum. The supernumerary head joined the common belly. It was supplied by the musculocutaneous nerve which after emerging from brachialis pierced it near the middle and terminated by finally supplying the biceps belly. In our study, 2.08% (1 of 48 of male cadavers were found to have the third head of biceps. The incidence of this variation can be as much as 10% as, shown in previous studies on Indian population, as reported in standard textbooks of anatomy.

  4. Toward an Understanding of Foreground Emission in the BICEP2 Region

    CERN Multimedia

    CERN. Geneva

    2014-01-01

    BICEP2 has reported the detection of a degree-scale B-mode polarization pattern in the Cosmic Microwave Background (CMB) and has interpreted the measurement as evidence for primordial gravitational waves. Motivated by the profound importance of the discovery of gravitational waves from the early Universe, I will discuss to what extent a combination of Galactic foregrounds and lensed E-modes could be responsible for the signal. I will present independent estimates of the dust polarization signal in the BICEP2 region using several different approaches. These estimates of the dust polarization signal in the BICEP2 region are consistent with each other, but the expected amplitude of the dust polarization power spectrum is uncertain by about a factor of three. The lower end of the prediction leaves room for a primordial contribution, but at the higher end the dust in combination with the standard CMB lensing signal could account for the BICEP2 observations, without requiring the existence of primordial gravitatio...

  5. Histochemistry profile of the biceps brachii muscle fibres of capuchin monkeys (Cebus apella, Linnaeus, 1758

    Directory of Open Access Journals (Sweden)

    CHF Bortoluci

    Full Text Available A general analysis of the behaviour of “Cebus” shows that when this primate moves position to feed or perform another activity, it presents different ways of locomotion. This information shows that the brachial biceps muscle of this animal is frequently used in their locomotion activities, but it should also be remembered that this muscle is also used for other development activities like hiding, searching for objects, searching out in the woods, and digging in the soil. Considering the above, it was decided to research the histoenzimologic characteristics of the brachial biceps muscle to observe whether it is better adpted to postural or phasic function. To that end, samples were taken from the superficial and deep regions, the inserts proximal (medial and lateral and distal brachial biceps six capuchin monkeys male and adult, which were subjected to the reactions of m-ATPase, NADH-Tr. Based on the results of these reactions fibres were classified as in Fast Twitch Glycolitic (FG, Fast Twitch Oxidative Glycolitic (FOG and Slow Twitc (SO. In general, the results, considering the muscle as a whole, show a trend of frequency FOG> FG> SO. The data on the frequency were studied on three superficial regions FOG=FG>SO; the deep regions of the inserts proximal FOG=FG=SO and inserting the distal FOG>FG=SO. In conclusion, the biceps brachii of the capuchin monkey is well adapted for both postural and phasic activities.

  6. Histochemistry profile of the biceps brachii muscle fibres of capuchin monkeys (Cebus apella, Linnaeus, 1758).

    Science.gov (United States)

    Bortoluci, C H F; Simionato, L H; Rosa Junior, G M; Oliveira, J A; Lauris, J R P; Moraes, L H R; Rodrigues, A C; Andreo, J C

    2014-08-01

    A general analysis of the behaviour of "Cebus" shows that when this primate moves position to feed or perform another activity, it presents different ways of locomotion. This information shows that the brachial biceps muscle of this animal is frequently used in their locomotion activities, but it should also be remembered that this muscle is also used for other development activities like hiding, searching for objects, searching out in the woods, and digging in the soil. Considering the above, it was decided to research the histoenzimologic characteristics of the brachial biceps muscle to observe whether it is better adpted to postural or phasic function. To that end, samples were taken from the superficial and deep regions, the inserts proximal (medial and lateral) and distal brachial biceps six capuchin monkeys male and adult, which were subjected to the reactions of m-ATPase, NADH-Tr. Based on the results of these reactions fibres were classified as in Fast Twitch Glycolitic (FG), Fast Twitch Oxidative Glycolitic (FOG) and Slow Twitc (SO). In general, the results, considering the muscle as a whole, show a trend of frequency FOG> FG> SO. The data on the frequency were studied on three superficial regions FOG=FG>SO; the deep regions of the inserts proximal FOG=FG=SO and inserting the distal FOG>FG=SO. In conclusion, the biceps brachii of the capuchin monkey is well adapted for both postural and phasic activities.

  7. Content Analysis Schedule for Bilingual Education Programs: BICEP Intercambio de la Cultura.

    Science.gov (United States)

    Shore, Marietta Saravia; Nafus, Charles

    This content analysis schedule for BICEP Intercambio de la Cultura (San Bernardino, California), presents information on the history, funding, and scope of the project. Included are sociolinguistic process variables such as the native and dominant languages of students and their interaction. Information is provided on staff selection and the…

  8. Solitary cysticercosis of the biceps brachii in a vegetarian: a rare and unusual pseudotumor

    Energy Technology Data Exchange (ETDEWEB)

    Abdelwahab, Ibrahim Fikry [Department of Radiology, New York Methodist Hospital Affiliated with Weill Medical College of Cornell University, 506 Sixth Street, Brooklyn, NY 11215 (United States); Klein, Michael J. [Department of Pathology, Mount Sinai Medical Center, 1 Gustave Levy Place, New York, NY 10029 (United States); Hermann, George [Department of Radiology, Mount Sinai Medical Center, 1 Gustave Levy Place, New York, NY 10029 (United States); Abdul-Quader, Mohammed [Department of Radiology, Columbia Presbyterian Medical Center, 177 Fort Washington Avenue, New York, NY 10032 (United States)

    2003-07-01

    We report a 40-year-old man with cysticercosis presenting as a solitary tumor in the biceps brachii muscle. Physical examination revealed an intramuscular mass and magnetic resonance imaging suggested a cyst. The histologic diagnosis was a cysticercus. Such solitary presentation of muscular cysticercosis is extremely rare with only a handful of sporadic reports in the literature. (orig.)

  9. SUSY see-saw and NMSO(10)GUT inflation after BICEP2

    Indian Academy of Sciences (India)

    2016-01-13

    Jan 13, 2016 ... Recently, BICEP2, a telescope mounted at the south pole for background imaging of cosmic extragalatic polarization claimed the detection of the signal of primordial gravitational waves. The gravitational waves active during the inflationary epoch produce polarization in cosmic microwave background.

  10. Solitary cysticercosis of the biceps brachii in a vegetarian: a rare and unusual pseudotumor

    International Nuclear Information System (INIS)

    Abdelwahab, Ibrahim Fikry; Klein, Michael J.; Hermann, George; Abdul-Quader, Mohammed

    2003-01-01

    We report a 40-year-old man with cysticercosis presenting as a solitary tumor in the biceps brachii muscle. Physical examination revealed an intramuscular mass and magnetic resonance imaging suggested a cyst. The histologic diagnosis was a cysticercus. Such solitary presentation of muscular cysticercosis is extremely rare with only a handful of sporadic reports in the literature. (orig.)

  11. Biceps brachii can add to performance of tasks requiring supination in cerebral palsy patients

    NARCIS (Netherlands)

    de Bruin, M.; Veeger, H.E.J.; Kreulen, M.; Smeulders, M.J.C.; Bus, S.A.

    2013-01-01

    The aim of this study was to assess whether cerebral palsy patients can use biceps brachii for supination during movement tasks requiring supination and pronation. 3D upper extremity kinematic and EMG-data of 12 patients (mean age 13. y 8. mo. ±. 36. mo) were compared to 10 healthy age-matched

  12. Biceps brachii can add to performance of tasks requiring supination in cerebral palsy patients

    NARCIS (Netherlands)

    de Bruin, M.; Veeger, H. E. J.; Kreulen, M.; Smeulders, M. J. C.; Bus, S. A.

    2013-01-01

    The aim of this study was to assess whether cerebral palsy patients can use biceps brachii for supination during movement tasks requiring supination and pronation. 3D upper extremity kinematic and EMG-data of 12 patients (mean age 13 y 8 mo ± 36 mo) were compared to 10 healthy age-matched controls.

  13. Strain sonoelastographic evaluation of biceps muscle intrinsic stiffness after botulinum toxin-A injection.

    Science.gov (United States)

    Aşkın, Ayhan; Kalaycı, Özlem Tuğçe; Bayram, Korhan Barış; Tosun, Aliye; Demirdal, Ümit Seçil; Atar, Emel; İnci, Mehmet Fatih

    2017-01-01

    The most commonly used clinical tools for measuring spasticity are modified Ashworth scale (MAS) and Tardieu scale but both yield subjective rather than objective results. Ultrasound elastography (EUS) provides information on tissue stiffness and allows the qualitative or quantitative measurements of the mechanical properties of tissues. To assess the stiffness of biceps brachialis muscles in stroke patients by strain EUS and to investigate the sonoelastographic changes and its correlations with clinical evaluation parameters after botulinum toxin-A (BTA) injections. This is a prospective study. A total of 48 chronic stroke patients requiring BTA injections to biceps brachialis muscles were included in the study. All patients received injections with BTA to biceps brachialis muscles under ultrasound guidance. MAS, goniometric measurements, and strain EUS assessments were performed at preintervention and at 4-week postintervention. Strain index values of biceps muscle on the affected side were significantly increased compared with those on the unaffected side (p < 0.01). At 4 weeks after BTA injection, significant improvements were observed in MAS grades and goniometric measurements (p < 0.05). Statistically significant differences were also found between the MAS grades and strain index values in both pre-/postintervention period (p < 0.01). No significant correlations were observed between clinical parameters and strain EUS findings. Strain EUS is a promising diagnostic tool for assessing stiffness in spastic muscles, in establishing the treatment plan and monitoring the effectiveness of the therapeutic modality.

  14. Shortened stapedius tendon: a rare cause of conductive hearing loss.

    Science.gov (United States)

    Zawawi, F; Varshney, R; Schloss, M D

    2014-01-01

    Anomalies of the stapedius tendon have been reported to cause conductive hearing loss; in theory, such anomalies limit the movement of the stapes. To demonstrate a rare cause of conductive hearing loss resulting from anomaly of the stapedius tendon and to compare the clinical findings of this patient to other stapedius tendon anomalies reported in the literature. Case report of a single case of shortened stapedius tendon and a review of the English literature on stapedius tendon anomalies. This is a case report of a 15-year-old boy with shortened stapedius tendon causing unilateral hearing loss, accompanied by a review of the literature. Contrary to other reported cases, this patient did not have an ossified tendon, but rather an extremely short tendon. The boy regained normal hearing following excision of the stapedius tendon. A shortened stapedius tendon is a very rare diagnosis, yet it should be considered as a possible cause of conductive hearing loss.

  15. What is the size of a floating sheath? An answer

    Science.gov (United States)

    Voigt, Farina; Naggary, Schabnam; Brinkmann, Ralf Peter

    2016-09-01

    The formation of a non-neutral boundary sheath in front of material surfaces is universal plasma phenomenon. Despite several decades of research, however, not all related issues are fully clarified. In a recent paper, Chabert pointed out that this lack of clarity applies even to the seemingly innocuous question ``What the size of a floating sheath?'' This contribution attempts to provide an answer that is not arbitrary: The size of a floating sheath is defined as the plate separation of an equivalent parallel plate capacitor. The consequences of the definition are explored with the help of a self-consistent sheath model, and a comparison is made with other sheath size definitions. Deutsche Forschungsgemeinschaft within SFB TR 87.

  16. Effect of collisions on photoelectron sheath in a gas

    Science.gov (United States)

    Sodha, Mahendra Singh; Mishra, S. K.

    2016-02-01

    This paper presents a study of the effect of the collision of electrons with atoms/molecules on the structure of a photoelectron sheath. Considering the half Fermi-Dirac distribution of photo-emitted electrons, an expression for the electron density in the sheath has been derived in terms of the electric potential and the structure of the sheath has been investigated by incorporating Poisson's equation in the analysis. The method of successive approximations has been used to solve Poisson's equation with the solution for the electric potential in the case of vacuum, obtained earlier [Sodha and Mishra, Phys. Plasmas 21, 093704 (2014)], being used as the zeroth order solution for the present analysis. The inclusion of collisions influences the photoelectron sheath structure significantly; a reduction in the sheath width with increasing collisions is obtained.

  17. Sheath impedance effects in very high frequency plasma experiments

    International Nuclear Information System (INIS)

    Schwarzenbach, W.; Howling, A.A.; Fivaz, M.; Brunner, S.; Hollenstein, C.

    1995-05-01

    The frequency dependence (13.56 MHz to 70 MHz) of the ion energy distribution at the ground electrode was measured by mass spectrometry in a symmetrical capacitive argon discharge. Reduced sheath impedance at Very High Frequency allows high levels of plasma power and substrate ion flux whilst maintaining low levels of ion energy and electrode voltage. The lower limit of ion bombardment energy is fixed by the sheath floating potential at high frequency, in contrast to low frequencies where only the rf voltage amplitude is determinant. The capacitive sheaths are thinner at high frequencies which accentuates the high frequency reduction in sheath impedance. It is argued that the frequency dependence of sheath impedance is responsible for the principal characteristics of Very High Frequency plasmas. The measurements are summarised by simple physical descriptions and compared with a Particle-In-Cell simulation. (author) figs., tabs., refs

  18. Similarities and distinctions of CIR and Sheath

    Science.gov (United States)

    Yermolaev, Yuri; Lodkina, Irina; Nikolaeva, Nadezhda; Yermolaev, Michael

    2016-04-01

    On the basis of OMNI data and our catalog of large scale solar wind (SW) streams during 1976-2000 [Yermolaev et al., 2009] we study the average temporal profiles for two types of compressed regions: CIR (corotating interaction region - compressed region before High Speed Stream (HSS)) and Sheath (compressed region before fast Interplanetary CMEs (ICMEs), including Magnetic Cloud (MC) and Ejecta). As have been shown by Nikolaeva et al, [2015], the efficiency of magnetic storm generation is ~50% higher for Sheath and CIR than for ICME (MC and Ejecta), i.e. reaction magnetosphere depends on type of driver. To take into account the different durations of SW types, we use the double superposed epoch analysis (DSEA) method: rescaling the duration of the interval for all types in such a manner that, respectively, beginning and end for all intervals of selected type coincide [Yermolaev et al., 2010; 2015]. Obtained data allows us to suggest that the formation of all types of compression regions has the same physical mechanism irrespective of piston (HSS or ICME) type and differences are connected with geometry and full jumps of speed in edges of compression regions. If making the natural assumption that the gradient of speed is directed approximately on normal to the piston, CIR has the largest angle between the gradient of speed and the direction of average SW speed, and ICME - the smallest angle. The work was supported by the Russian Foundation for Basic Research, projects 13-02-00158, 16-02-00125 and by Program of Presidium of the Russian Academy of Sciences. References: Nikolaeva, N. S. , Yu. I. Yermolaev, and I. G. Lodkina (2015), Modeling of the Corrected Dst* Index Temporal Profile on the Main Phase of the Magnetic Storms Generated by Different Types of Solar Wind, Cosmic Research, Vol. 53, No. 2, pp. 119-127. Yermolaev, Yu. I., N. S. Nikolaeva, I. G. Lodkina, and M. Yu. Yermolaev (2009), Catalog of Large-Scale Solar Wind Phenomena during 1976-2000, Cosmic Research

  19. One-stage treatment of delayed 'jersey finger' by Z-step lengthening of the flexor digitorum profundus tendon at the wrist.

    Science.gov (United States)

    Sawaya, Elias T; Choughri, Hussein; Pelissier, Philippe

    2012-02-01

    The authors report the case of a 19-year-old female with delayed presentation of a type II 'jersey finger' of the fourth dominant digit. A surgical approach was performed, revealing a retracted flexor digitorum profundus tendon within a still patent sheath. The resulting loss of tendon length overruled any possibility of direct reinsertion of the tendon. A lengthening "Z-step" tendinoplasty was then performed on the tendon at the wrist, thus enabling reinsertion at the base of the distal phalanx. The patient then underwent conventional splinting and physiotherapy. Total Active Motion was measured at 220° with a 6-month follow-up. Even though there is no clear consensus concerning management of such cases, different techniques have been described, such as one- or two-stage grafting, or tenotomy at the musculotendinous junction. Lengthening tendinoplasties have been applied by certain authors but only to the flexor pollicis longus tendon. To our knowledge, this is the only reported case of lengthening Z-step applied to a long digit for the repair of type II 'jersey finger' lesions. The satisfactory functional and cosmetic outcome encourages us to consider this one-stage technique in other select cases, in order to gather more formal evidence. Copyright © 2011 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  20. Sheath rendezvous method: a novel distal protection technique during endovascular treatment of subclavian artery occlusions.

    Science.gov (United States)

    Haraguchi, Takuya; Urasawa, Kazushi; Nakama, Tatsuya; Nakagawa, Yuya; Tan, Michinao; Koshida, Ryoji; Sato, Katsuhiko

    2016-10-01

    To describe an innovative distal protection technique, "sheath rendezvous method", during endovascular treatment for subclavian arterial occlusions. 4.5F and 6F guiding sheath were inserted from left brachial and common femoral artery, respectively. 0.014″ guidewire retrogradely passed through occlusion and into antegrade sheath to establish a pull-through system. 3.0 mm balloon was used to expand occlusion and anchor to deliver retrograde sheath into antegrade one. Both sheaths locked by balloon dilatation crossed occlusion until antegrade sheath passed over lesion. Balloon expandable stent was delivered within antegrade sheath. Sheath was removed, and stent was implanted. We obtained an excellent outcome without complications.

  1. Reliability of biceps femoris and semitendinosus muscle architecture measurements obtained with ultrasonography

    Directory of Open Access Journals (Sweden)

    Viviane Bastos de Oliveira

    Full Text Available Introduction Currently, little attention is given to the muscle architecture reliability studies of the hamstring using a robust statistical. Our purpose was to determine the reliability of ultrasound measurements of muscle thickness, fascicle length and pennation angle of the biceps femoris and semitendinosus muscles, including heteroskedasticity and internal consistency analyses. Methods Two images of biceps femoris and semitendinosus at 50% of the thigh length were acquired from 21 volunteers, in two visits. The parameters were measured three times in each image, and for each muscle. The reliability was analyzed by the intraclass correlation coefficient (ICC and Cronbach’s alpha (αCronbach. The relative standard error of the measurements (%SEM were calculated and Bland-Altman plots were generated. Results All parameters presented excellent ICC for the three repeated measurements (ICC from 0.93 ‒ 0.99 and moderate to excellent reliability intraday (ICC from 0.70 ‒ 0.95 for both muscles. The present study indicates that ultrasound is a reliable tool to estimate the biceps femoris fascicle length (ICC = 0.97, αCronbach = 0.98, %SEM = 7.86 and semitendinosus (ICC = 0.90, αCronbach = 0.95, %SEM = 7.55, as well as the biceps femoris muscle thickness (ICC = 0.89, αCronbach = 0.94, %SEM = 10.23 and semitendinosus muscle thickness (ICC = 0.87, αCronbach = 0.93, %SEM = 1.35. At last, biceps femoris pennation angle (ICC = 0.93, αCronbach = 0.96 and %SEM = 4.36 and semitendinosus (ICC = 0.96, αCronbach = 0.98 and %SEM = 4.25 also had good repeatability. Conclusion Ultrasonography show good repeatability in estimating of muscle architecture parameters.

  2. Characteristics of metal sheathed thermocouples in thermowell

    International Nuclear Information System (INIS)

    Okuda, Takehiro; Nakase, Tsuyoshi; Tanabe, Yutaka; Yamada, Kunitaka; Yoshizaki, Akio; Roko, Kiyokazu

    1987-01-01

    Static and dynamic characteristics of thermowell type thermocouples which are planned to be used for the High-Temperature engineering Test Reactor (HTTR) have been investigated. A mock-up test section was installed in Kawasaki's Helium Test Loop (KH-200). Thermal characteristics tests were carried out under the 600 ∼ 1000 deg C temperature conditions. The test section was equipped with four types sheathed thermocouples; the well type, the non well type, and ones with and without the thermal radiation shielding plate. The measured temperature by the well type thermocouples with the shielding plate was only about 1.3 deg C higher than the one without the shielding plate at gas temperature 990 deg C. The measured time constant of the well type thermocouples was about 7 seconds in the condition of the heat transfer coefficient 1600 Kcal/m 2 h deg C on the well surface, and coincided with the calculated one by ''TRUMP'' code. (author)

  3. Benign nerve sheath tumor of stomach

    International Nuclear Information System (INIS)

    Chaudry, N.U.; Zafar, S.; Haque, I.U.

    2007-01-01

    Gastrointestinal mesenchymal tumors are a group of tumors, which originate from the mesenchymal stem cells of the gastrointestinal tract. Gastric schwannoma is a very rare gastrointestinal mesenchymal tumor, which represents only 0.2% of all gastric tumors and 4% of all benign gastric neoplasms. We report a 55 years old lady who suffered from pain epigastrium, vomiting, occasionally with blood, loss of appetite and weight loss. Endoscopic examination showed a round submucosal tumor with a central ulceration along the greater curvature of the stomach. The pathological examination revealed a picture of spindle cell tumor. Immunohistochemical stain was strongly positive for S-100 protein stain, and non-reactive for CD34, CD117, consistent with benign nerve sheath tumor of stomach i.e. gastric schwannoma. (author)

  4. Estimation of radiation losses from sheathed thermocouples

    International Nuclear Information System (INIS)

    Roberts, I.L.; Coney, J.E.R.; Gibbs, B.M.

    2011-01-01

    Thermocouples are often used for temperature measurements in heat exchangers. However if the radiation losses from a thermocouple in a high temperature gas flow to colder surroundings are ignored significant errors can occur. Even at moderate temperature differences, these can be significant. Prediction of radiation losses from theory can be problematic, especially in situations where there are large variations in the measured temperatures as the emissivity and radiative heat transfer coefficient of the thermocouple are not constant. The following approach combines experimental results with established empirical relationships to estimate losses due to radiation in an annular heat exchanger at temperatures up to 950 o C. - Highlights: → Sheathed thermocouples are often used to measure temperatures in heat exchangers. → Errors are introduced if radiation losses are ignored. → Radiation losses are environment specific and may be significant. → Experimental and theoretical methods are used to estimate losses. → Hot side maximum temperature 950 o C.

  5. The Sheath-less Planar Langmuir Probe

    Science.gov (United States)

    Cooke, D. L.

    2017-12-01

    The Langmuir probe is one of the oldest plasma diagnostics, provided the plasma density and species temperature from analysis of a current-voltage curve as the voltage is swept over a practically chosen range. The analysis depends on a knowledge or theory of the many factors that influence the current-voltage curve including, probe shape, size, nearby perturbations, and the voltage reference. For applications in Low Earth Orbit, the Planar Langmuir Probe, PLP, is an attractive geometry because the ram ion current is very constant over many Volts of a sweep, allowing the ion density and electron temperature to be determined independently with the same instrument, at different points on the sweep. However, when the physical voltage reference is itself small and electrically floating as with a small spacecraft, the spacecraft and probe system become a double probe where the current collection theory depends on the interaction of the spacecraft with the plasma which is generally not as simple as the probe itself. The Sheath-less PLP, SPLP, interlaces on a single ram facing surface, two variably biased probe elements, broken into many small and intertwined segments on a scale smaller than the plasma Debye length. The SPLP is electrically isolated from the rest of the spacecraft. For relative bias potentials of a few volts, the ion current to all segments of each element will be constant, while the electron currents will vary as a function of the element potential and the electron temperature. Because the segments are small, intertwined, and floating, the assembly will always present the same floating potential to the plasma, with minimal growth as a function of voltage, thus sheath-less and still planar. This concept has been modelled with Nascap, and tested with a physical model inserted into a Low Earth Orbit-like chamber plasma. Results will be presented.

  6. [Flexor tendon repair: a short story].

    Science.gov (United States)

    Moutet, F; Corcella, D; Forli, A; Mesquida, V

    2014-12-01

    This short story of flexor tendon repair aims to illustrate hesitations and wanderings of this surgery. Obviously tendon repair was very early considered, but it developed and diffused rather lately. It became a routine practice only in 20th century. This was due on the one hand, in Occident, to the Galen's dogmatic interdiction, on the other hand, to the repair difficulties of this paradoxical structure. Actually tendon is made of fibroblasts and collagen (sticky substances), and then its only goal is to move. According to this necessity, whatever the used techniques are, gliding is the final purpose. Technical evolutions are illustrated by historical contributions to flexor tendon surgery of several "giants" of hand surgery. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  7. Terminology for Achilles tendon related disorders

    NARCIS (Netherlands)

    van Dijk, C. N.; van Sterkenburg, M. N.; Wiegerinck, J. I.; Karlsson, J.; Maffulli, N.

    2011-01-01

    The terminology of Achilles tendon pathology has become inconsistent and confusing throughout the years. For proper research, assessment and treatment, a uniform and clear terminology is necessary. A new terminology is proposed; the definitions hereof encompass the anatomic location, symptoms,

  8. Endoscopic Treatment of Intrasheath Peroneal Tendon Subluxation

    Directory of Open Access Journals (Sweden)

    Frederick Michels

    2013-01-01

    Full Text Available Intrasheath subluxation of the peroneal tendons within the peroneal groove is an uncommon problem. Open exploration combined with a peroneal groove-deepening procedure and retinacular reefing is the recommended treatment. This extensive lateral approach needs incision of the intact superior peroneal retinaculum and repair afterwards. We treated three patients with a painful intrasheath subluxation using an endoscopic approach. During this tendoscopy both tendons were inspected. The distal muscle fibers of the peroneus brevis tendon were resected in two patients. A partial tear was debrided in the third patient. All patients had a good result. No wound-healing problems or other complications occurred. Early return to work and sports was possible. An endoscopic approach was successful in treatment of an intrasheath subluxation of the peroneal tendons.

  9. Quadriceps Tendon Autograft Medial Patellofemoral Ligament Reconstruction.

    Science.gov (United States)

    Fink, Christian; Steensen, Robert; Gföller, Peter; Lawton, Robert

    2018-06-01

    Critically evaluate the published literature related to quadriceps tendon (QT) medial patellofemoral ligament (MPFL) reconstruction. Hamstring tendon (HT) MPFL reconstruction techniques have been shown to successfully restore patella stability, but complications including patella fracture are reported. Quadriceps tendon (QT) reconstruction techniques with an intact graft pedicle on the patella side have the advantage that patella bone tunnel drilling and fixation are no longer needed, reducing risk of patella fracture. Several QT MPFL reconstruction techniques, including minimally invasive surgical (MIS) approaches, have been published with promising clinical results and fewer complications than with HT techniques. Parallel laboratory studies have shown macroscopic anatomy and biomechanical properties of QT are more similar to native MPFL than hamstring (HS) HT, suggesting QT may more accurately restore native joint kinematics. Quadriceps tendon MPFL reconstruction, via both open and MIS techniques, have promising clinical results and offer valuable alternatives to HS grafts for primary and revision MPFL reconstruction in both children and adults.

  10. Jumper's Knee (Patellar Tendonitis) (For Parents)

    Science.gov (United States)

    ... Safe Videos for Educators Search English Español Jumper's Knee (Patellar Tendonitis) KidsHealth / For Parents / Jumper's Knee (Patellar ... prevent continued damage to the knee. How the Knee Works To understand how jumper's knee happens, it ...

  11. Experimental tests of pretensioned high strength tendons

    International Nuclear Information System (INIS)

    Hajutin, J.G.; Kriczewskij, A.Z.

    1977-01-01

    The tests carried out to estimate the losses of the prestressing force and the real bearing capacity of the parallel wire tendons and seven-wire strands are described. The practical experiences in tenden anchoring etc. are also received. (author)

  12. Investigations related to failure of prestressing tendons

    International Nuclear Information System (INIS)

    Boyadjiev, Z.

    1995-01-01

    Kozloduy NPP units 5 and 6 containment cladding shells are prestressed by the use of tendons 450 φ 5, made of high strength wires, class B-II. The prestressing force for each tendon is 10000 kN and the calculated breakdown force - 14000 kN. There are 96 tendons in the cylindrical part of the shell and 36 ones located in the containment dome. They are located in channel forming tubes of inner diameter of 200 mm, made of dense polyethylene. In order to assure biaxial prestressed condition, the prestressing tendons are located on screw shaped lines, both left and right, with declination to the horizon 35 degrees and 15 minutes. Each prestressing tendon initially forms a knee and following the bending at elevation + 10.80 m forms the other knee, in such a way, that its two ends are anchored in one and the same area-in a common or adjacent upper anchor boxes. The prestressing tendons in the containment dome are located in two perpendicular rows. Both ends of each tendon are anchored in a common fixing, the tendon being bent to the opposite side of the dome. During construction and operation of units 5 and 6, it was found, that the design prestressing force of 10000 kN can not be reached with some tendons, due to separate wires ruptures or due to the anchoring screw spent thread. The 1992 preliminary wires tests on a failed tendon found out deformation properties, different from the systematically obtained ones for the initial steel. Taking into consideration this fact, together with the IAEA regional project, concerning WWER-1000 seismic safety and items 4 and 6 of Kozloduy NPP Technical Council decisions of 10 June 1993, brought to delegation to the Research Construction Institute the performance of the technical analysis of the applied system for shell prestressing of containments of of units 5 and 6. The analysis comprises physical-mechanical and rheological properties of the high strength wires, used for containment shell prestressing and the over all technological

  13. Use of guiding sheaths in peroral fluoroscopic gastroduodenal stent placement

    International Nuclear Information System (INIS)

    Bae, Jae-Ik; Shin, Ji Hoon; Song, Ho-Young; Yoon, Chang Jin; Nam, Deok Ho; Choi, Won-Chan; Lim, Jin-Oh

    2005-01-01

    Our purpose was to assess the safety and usefulness of guiding sheaths in peroral fluoroscopic gastroduodenal stent placement. Two types of guiding sheath were made from straight polytetrafluoroethylene tubes. Type A was 80 cm in length, 4 mm in outer diameter and 3 mm in inner diameter. Type B was 70 cm in length, 6 mm in outer diameter and 5 mm in inner diameter. The type A sheath was used in 18 patients in whom a catheter-guide wire combination failed to pass through a stricture. The type B sheath was used in 22 patients in whom a stent delivery system failed to pass through the stricture due to loop formation within the gastric lumen. The overall success rate for guiding a catheter-guide wire through a stricture after using the type A sheath was 89%. The overall success rate for passing a stent delivery system through a stricture after using the type B sheath was 100%. All procedures were tolerated by the patients without any significant complications. The guiding sheaths were safe and useful in peroral fluoroscopic gastroduodenal stent placement. (orig.)

  14. ALINE: A device dedicated to understanding radio-frequency sheaths

    Directory of Open Access Journals (Sweden)

    S. Devaux

    2017-08-01

    Full Text Available In fusion devices, radiofrequency (RF antennas are used for heating the plasma. Those antennas and the plasma interact with each other through the so-called RF sheaths, layers of plasma where the quasi-neutrality breaks down and large electric fields arise. Among the effects of RF sheaths, there is the enhancement of the particles and energy fluxes toward the surface of the antenna, which in turn generate hot spots and release impurities, which are both deleterious for plasma operations. RF sheaths comprehension stumbles on the difficulty to achieve in situ measurements of the sheath properties, as scrape-off layer plasmas are a harsh environment. The very goal of the ALINE device is to tackle this issue and to fulfil the blank between numerical simulations and full-scale experiment by providing measurements within the RF sheaths in a controlled environment. In this paper we report on the latest experimental results from ALINE, in which a cylindrical Langmuir probe mounted on a remotely controlled and programmable arm allows for plasma characterizations in the three dimensions of space around the stainless steel antenna, including the sheath. We present a series of density and potential profiles and three dimension (3D maps in the plasma surrounding a stainless-steel RF antenna as well as in the sheath itself, for unmagnetized and magnetized plasmas.

  15. Abiotic Deposition of Fe Complexes onto Leptothrix Sheaths

    Science.gov (United States)

    Kunoh, Tatsuki; Hashimoto, Hideki; McFarlane, Ian R.; Hayashi, Naoaki; Suzuki, Tomoko; Taketa, Eisuke; Tamura, Katsunori; Takano, Mikio; El-Naggar, Mohamed Y.; Kunoh, Hitoshi; Takada, Jun

    2016-01-01

    Bacteria classified in species of the genus Leptothrix produce extracellular, microtubular, Fe-encrusted sheaths. The encrustation has been previously linked to bacterial Fe oxidases, which oxidize Fe(II) to Fe(III) and/or active groups of bacterial exopolymers within sheaths to attract and bind aqueous-phase inorganics. When L. cholodnii SP-6 cells were cultured in media amended with high Fe(II) concentrations, Fe(III) precipitates visibly formed immediately after addition of Fe(II) to the medium, suggesting prompt abiotic oxidation of Fe(II) to Fe(III). Intriguingly, these precipitates were deposited onto the sheath surface of bacterial cells as the population was actively growing. When Fe(III) was added to the medium, similar precipitates formed in the medium first and were abiotically deposited onto the sheath surfaces. The precipitates in the Fe(II) medium were composed of assemblies of globular, amorphous particles (ca. 50 nm diameter), while those in the Fe(III) medium were composed of large, aggregated particles (≥3 µm diameter) with a similar amorphous structure. These precipitates also adhered to cell-free sheaths. We thus concluded that direct abiotic deposition of Fe complexes onto the sheath surface occurs independently of cellular activity in liquid media containing Fe salts, although it remains unclear how this deposition is associated with the previously proposed mechanisms (oxidation enzyme- and/or active group of organic components-involved) of Fe encrustation of the Leptothrix sheaths. PMID:27271677

  16. Abiotic Deposition of Fe Complexes onto Leptothrix Sheaths

    Directory of Open Access Journals (Sweden)

    Tatsuki Kunoh

    2016-06-01

    Full Text Available Bacteria classified in species of the genus Leptothrix produce extracellular, microtubular, Fe-encrusted sheaths. The encrustation has been previously linked to bacterial Fe oxidases, which oxidize Fe(II to Fe(III and/or active groups of bacterial exopolymers within sheaths to attract and bind aqueous-phase inorganics. When L. cholodnii SP-6 cells were cultured in media amended with high Fe(II concentrations, Fe(III precipitates visibly formed immediately after addition of Fe(II to the medium, suggesting prompt abiotic oxidation of Fe(II to Fe(III. Intriguingly, these precipitates were deposited onto the sheath surface of bacterial cells as the population was actively growing. When Fe(III was added to the medium, similar precipitates formed in the medium first and were abiotically deposited onto the sheath surfaces. The precipitates in the Fe(II medium were composed of assemblies of globular, amorphous particles (ca. 50 nm diameter, while those in the Fe(III medium were composed of large, aggregated particles (≥3 µm diameter with a similar amorphous structure. These precipitates also adhered to cell-free sheaths. We thus concluded that direct abiotic deposition of Fe complexes onto the sheath surface occurs independently of cellular activity in liquid media containing Fe salts, although it remains unclear how this deposition is associated with the previously proposed mechanisms (oxidation enzyme- and/or active group of organic components-involved of Fe encrustation of the Leptothrix sheaths.

  17. Farris-Tang retractor in optic nerve sheath decompression surgery.

    Science.gov (United States)

    Spiegel, Jennifer A; Sokol, Jason A; Whittaker, Thomas J; Bernard, Benjamin; Farris, Bradley K

    2016-01-01

    Our purpose is to introduce the use of the Farris-Tang retractor in optic nerve sheath decompression surgery. The procedure of optic nerve sheath fenestration was reviewed at our tertiary care teaching hospital, including the use of the Farris-Tang retractor. Pseudotumor cerebri is a syndrome of increased intracranial pressure without a clear cause. Surgical treatment can be effective in cases in which medical therapy has failed and disc swelling with visual field loss progresses. Optic nerve sheath decompression surgery (ONDS) involves cutting slits or windows in the optic nerve sheath to allow cerebrospinal fluid to escape, reducing the pressure around the optic nerve. We introduce the Farris-Tang retractor, a retractor that allows for excellent visualization of the optic nerve sheath during this surgery, facilitating the fenestration of the sheath and visualization of the subsequent cerebrospinal fluid egress. Utilizing a medial conjunctival approach, the Farris-Tang retractor allows for easy retraction of the medial orbital tissue and reduces the incidence of orbital fat protrusion through Tenon's capsule. The Farris-Tang retractor allows safe, easy, and effective access to the optic nerve with good visualization in optic nerve sheath decompression surgery. This, in turn, allows for greater surgical efficiency and positive patient outcomes.

  18. The Tubular Sheaths Encasing Methanosaeta thermophila Filaments Are Functional Amyloids.

    Science.gov (United States)

    Dueholm, Morten S; Larsen, Poul; Finster, Kai; Stenvang, Marcel R; Christiansen, Gunna; Vad, Brian S; Bøggild, Andreas; Otzen, Daniel E; Nielsen, Per Halkjær

    2015-08-14

    Archaea are renowned for their ability to thrive in extreme environments, although they can be found in virtually all habitats. Their adaptive success is linked to their unique cell envelopes that are extremely resistant to chemical and thermal denaturation and that resist proteolysis by common proteases. Here we employ amyloid-specific conformation antibodies and biophysical techniques to show that the extracellular cell wall sheaths encasing the methanogenic archaea Methanosaeta thermophila PT are functional amyloids. Depolymerization of sheaths and subsequent MS/MS analyses revealed that the sheaths are composed of a single major sheath protein (MspA). The amyloidogenic nature of MspA was confirmed by in vitro amyloid formation of recombinant MspA under a wide range of environmental conditions. This is the first report of a functional amyloid from the archaeal domain of life. The amyloid nature explains the extreme resistance of the sheath, the elastic properties that allow diffusible substrates to penetrate through expandable hoop boundaries, and how the sheaths are able to split and elongate outside the cell. The archaeal sheath amyloids do not share homology with any of the currently known functional amyloids and clearly represent a new function of the amyloid protein fold. © 2015 by The American Society for Biochemistry and Molecular Biology, Inc.

  19. Dynamic ultrasound of peroneal tendon instability.

    Science.gov (United States)

    Pesquer, Lionel; Guillo, Stéphane; Poussange, Nicolas; Pele, Eric; Meyer, Philippe; Dallaudière, Benjamin

    2016-07-01

    Ankle snapping may be caused by peroneal tendon instability. Anterior instability occurs after traumatic superior peroneal retinaculum injury, whereas peroneal tendon intrasheath subluxation is atraumatic. Whereas subluxation is mainly dynamic, ultrasound allows for the diagnosis and classification of peroneal instability because it allows for real-time exploration. The purpose of this review is to describe the anatomic and physiologic bases for peroneal instability and to heighten the role of dynamic ultrasound in the diagnosis of snapping.

  20. Optimization of human tendon tissue engineering: peracetic acid oxidation for enhanced reseeding of acellularized intrasynovial tendon.

    Science.gov (United States)

    Woon, Colin Y L; Pridgen, Brian C; Kraus, Armin; Bari, Sina; Pham, Hung; Chang, James

    2011-03-01

    Tissue engineering of human flexor tendons combines tendon scaffolds with recipient cells to create complete cell-tendon constructs. Allogenic acellularized human flexor tendon has been shown to be a useful natural scaffold. However, there is difficulty repopulating acellularized tendon with recipient cells, as cell penetration is restricted by a tightly woven tendon matrix. The authors evaluated peracetic acid treatment in optimizing intratendinous cell penetration. Cadaveric human flexor tendons were harvested, acellularized, and divided into experimental groups. These groups were treated with peracetic acid in varying concentrations (2%, 5%, and 10%) and for varying time periods (4 and 20 hours) to determine the optimal treatment protocol. Experimental tendons were analyzed for differences in tendon microarchitecture. Additional specimens were reseeded by incubation in a fibroblast cell suspension at 1 × 10(6) cells/ml. This group was then analyzed for reseeding efficacy. A final group underwent biomechanical studies for strength. The optimal treatment protocol comprising peracetic acid at 5% concentration for 4 hours produced increased scaffold porosity, improving cell penetration and migration. Treated scaffolds did not show reduced collagen or glycosaminoglycan content compared with controls (p = 0.37 and p = 0.65, respectively). Treated scaffolds were cytotoxic to neither attached cells nor the surrounding cell suspension. Treated scaffolds also did not show inferior ultimate tensile stress or elastic modulus compared with controls (p = 0.26 and p = 0.28, respectively). Peracetic acid treatment of acellularized tendon scaffolds increases matrix porosity, leading to greater reseeding. It may prove to be an important step in tissue engineering of human flexor tendon using natural scaffolds.

  1. Grasp Assist Device with Shared Tendon Actuator Assembly

    Science.gov (United States)

    Ihrke, Chris A. (Inventor); Bergelin, Bryan J. (Inventor); Bridgwater, Lyndon (Inventor)

    2015-01-01

    A grasp assist device includes a glove with first and second tendon-driven fingers, a tendon, and a sleeve with a shared tendon actuator assembly. Tendon ends are connected to the respective first and second fingers. The actuator assembly includes a drive assembly having a drive axis and a tendon hook. The tendon hook, which defines an arcuate surface slot, is linearly translatable along the drive axis via the drive assembly, e.g., a servo motor thereof. The flexible tendon is routed through the surface slot such that the surface slot divides the flexible tendon into two portions each terminating in a respective one of the first and second ends. The drive assembly may include a ball screw and nut. An end cap of the actuator assembly may define two channels through which the respective tendon portions pass. The servo motor may be positioned off-axis with respect to the drive axis.

  2. Natural inflation: consistency with cosmic microwave background observations of Planck and BICEP2

    International Nuclear Information System (INIS)

    Freese, Katherine; Kinney, William H.

    2015-01-01

    Natural inflation is a good fit to all cosmic microwave background (CMB) data and may be the correct description of an early inflationary expansion of the Universe. The large angular scale CMB polarization experiment BICEP2 has announced a major discovery, which can be explained as the gravitational wave signature of inflation, at a level that matches predictions by natural inflation models. The natural inflation (NI) potential is theoretically exceptionally well motivated in that it is naturally flat due to shift symmetries, and in the simplest version takes the form V(φ) = Λ 4  [1 ± cos(Nφ/f)]. A tensor-to-scalar ratio r > 0.1 as seen by BICEP2 requires the height of any inflationary potential to be comparable to the scale of grand unification and the width to be comparable to the Planck scale. The Cosine Natural Inflation model agrees with all cosmic microwave background measurements as long as f ≥ m Pl (where m Pl  = 1.22 × 10 19  GeV) and Λ ∼ m GUT  ∼ 10 16  GeV. This paper also discusses other variants of the natural inflation scenario: we show that axion monodromy with potential V∝ φ 2/3 is inconsistent with the BICEP2 limits at the 95% confidence level, and low-scale inflation is strongly ruled out. Linear potentials V ∝ φ are inconsistent with the BICEP2 limit at the 95% confidence level, but are marginally consistent with a joint Planck/BICEP2 limit at 95%. We discuss the pseudo-Nambu Goldstone model proposed by Kinney and Mahanthappa as a concrete realization of low-scale inflation. While the low-scale limit of the model is inconsistent with the data, the large-field limit of the model is marginally consistent with BICEP2. All of the models considered predict negligible running of the scalar spectral index, and would be ruled out by a detection of running

  3. Microstructural stress relaxation mechanics in functionally different tendons.

    Science.gov (United States)

    Screen, H R C; Toorani, S; Shelton, J C

    2013-01-01

    Tendons experience widely varying loading conditions in vivo. They may be categorised by their function as either positional tendons, which are used for intricate movements and experience lower stress, or as energy storage tendons which act as highly stressed springs during locomotion. Structural and compositional differences between tendons are thought to enable an optimisation of their properties to suit their functional environment. However, little is known about structure-function relationships in tendon. This study adopts porcine flexor and extensor tendon fascicles as examples of high stress and low stress tendons, comparing their mechanical behaviour at the micro-level in order to understand their stress relaxation response. Stress-relaxation was shown to occur predominantly through sliding between collagen fibres. However, in the more highly stressed flexor tendon fascicles, more fibre reorganisation was evident when the tissue was exposed to low strains. By contrast, the low load extensor tendon fascicles appears to have less capacity for fibre reorganisation or shearing than the energy storage tendon, relying more heavily on fibril level relaxation. The extensor fascicles were also unable to sustain loads without rapid and complete stress relaxation. These findings highlight the need to optimise tendon repair solutions for specific tendons, and match tendon properties when using grafts in tendon repairs. Copyright © 2012 IPEM. Published by Elsevier Ltd. All rights reserved.

  4. Ultrasonographic findings of pilar sheath acanthoma: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Dong Joo; Lee, Sun Joo; Kim, Seong Jin [Inje University College of Medicine, Busan Paik Hospital, Busan (Korea, Republic of)

    2017-08-15

    Pilar sheath acanthoma is a rare benign follicular hamartoma that presents with a central sinus containing keratinous material and is lined by epithelium. It typically occurs on the face, especially on the upper lip and forehead. In our case, the ultrasound (US) feature of pilar sheath acanthoma revealed a well-defined, oval hypoechoic nodule with hypoechoic capping within the dermis over the medial aspect of the calf. To the best of our knowledge, despite many reports on the clinicopathological aspects of pilar sheath acanthoma, this entity has not been well described in the radiologic literature, and US findings have not been documented.

  5. Experimental test of models of radio-frequency plasma sheaths

    International Nuclear Information System (INIS)

    Sobolewski, M.A.

    1997-01-01

    The ion current and sheath impedance were measured at the radio-frequency-powered electrode of an asymmetric, capacitively coupled plasma reactor, for discharges in argon at 1.33 endash 133 Pa. The measurements were used to test the models of the radio frequency sheath derived by Lieberman [IEEE Trans. Plasma Sci. 17, 338 (1989)] and Godyak and Sternberg [Phys. Rev. A 42, 2299 (1990)], and establish the range of pressure and sheath voltage in which they are valid. copyright 1997 American Institute of Physics

  6. Dynamics of Dust in a Plasma Sheath with Magnetic Field

    International Nuclear Information System (INIS)

    Duan Ping; Liu Jinyuan; Gon Ye; Liu Yue; Wang Xiaogang

    2007-01-01

    Dynamics of dust in a plasma sheath with a magnetic field was investigated using a single particle model. The result shows that the radius, initial position, initial velocity of the dust particles and the magnetic field do effect their movement and equilibrium position in the plasma sheath. Generally, the dust particles with the same size, whatever original velocity and position they have, will locate at the same position in the end under the net actions of electrostatic, gravitational, neutral collisional, and Lorentz forces. But the dust particles will not locate in the plasma sheath if their radius is beyond a certain value

  7. Local trauma in human patellar tendon leads to widespread changes in the tendon gene expression

    DEFF Research Database (Denmark)

    Heinemeier, Katja Maria; Lorentzen, Marc P; Kildevang Jensen, Jacob

    2016-01-01

    Low cellular activity and slow tissue turnover in human tendon may prolong resolution of tendinopathy. This may be stimulated by moderate localized traumas such as needle penetrations, but whether this results in a widespread cellular response in tendons is unknown. In an initial hypothesis-gener...

  8. Structural tendon changes in patients with acromegaly: assessment of Achilles tendon with sonoelastography.

    Science.gov (United States)

    Onal, Eda Demil; Ipek, Ali; Evranos, Berna; Idilman, Ilkay Sedakat; Cakir, Bekir; Ersoy, Reyhan

    2016-03-01

    To describe the sonoelastographic appearance of the Achilles tendon in acromegalic patients and to determine whether the blood concentrations of growth hormone (GH) and insulin-like growth factor (IGF-1) are associated with the various sonographic elasticity types of Achilles tendons. Eighty-four Achilles tendons of 42 acromegaly patients and 84 Achilles tendons of 42 healthy volunteers were assessed with sonoelastography. The tendons were classified into two main types according to the elasticity features: type 1 blue/green (hard tissue) and type 2 yellow/red within green (intermediate-soft tissue). Two subtypes of these types were also defined. According to the definition, the elasticity of the tissue was in a spectrum ranging from hard to soft as the type progressed from 1a to 2b. The mean thickness of Achilles tendons in patients with acromegaly was significantly higher compared with healthy Achilles tendons (5.1+/-0.7 mm vs. 4.4+/-0.5, pacromegaly patients had type 2 sonoelastographic appearance of the Achilles tendon (124/252 third; 49.2% vs. 81/252 third; 32.1%, p=0.0001). Activity status of acromegaly and GH/IGF-I levels were similar in patients with different types of elasticity (p>0.05). Sonoelastography revealed structural changes in the tendinous tissue of patients with acromegaly, but it was not sensitive enough to reflect changes in the serum levels of GH/IGF-1.

  9. Histological Changes in the Proximal and Distal Tendon Stumps Following Transection of Achilles Tendon in the Rabbits.

    Science.gov (United States)

    Al-Qattan, Mohammad M; Mawlana, Ola Helmi; Mohammed Ahmed, Raeesa Abdel-Twab; Hawary, Khalid

    2016-05-01

    To determine tendon stump changes following unrepaired Achilles tendon lacerations in an animal model. An experimental study. King Saud University, Riyadh, Saudi Arabia, from October 2013 to January 2014. Arabbit model was developed and studied tendon retraction and histological changes in the proximal and distal stumps following transection of the Achilles tendon. Over a period of 12 weeks, retraction of the distal tendon stump was minimal (2 - 3 mm). In contrast, retraction of the proximal tendon stump peaked to reach 6 mm at 4 weeks post-injury and plateaued to reach 7 - 8 mm at the 12-week interval. Following complete transection of the Achilles tendon, tendon retraction correlated with the density of myofibroblast expression within the tendon stump. Further research is needed to investigate the pathophysiology of these findings.

  10. Histological Changes in the Proximal and Distal Tendon Stumps Following Transection of Achilles Tendon in the Rabbits

    International Nuclear Information System (INIS)

    Al-Qattan, M. M.; Hawary, K.; Mawlana, O. H.; Ahmed, R. A. M.

    2016-01-01

    Objective: To determine tendon stump changes following unrepaired Achilles tendon lacerations in an animal model. Study Design: An experimental study. Place and Duration of Study: King Saud University, Riyadh, Saudi Arabia, from October 2013 to January 2014. Methodology: Arabbit model was developed and studied tendon retraction and histological changes in the proximal and distal stumps following transection of the Achilles tendon. Result: Over a period of 12 weeks, retraction of the distal tendon stump was minimal (2 - 3 mm). In contrast, retraction of the proximal tendon stump peaked to reach 6 mm at 4 weeks post-injury and plateaued to reach 7 - 8 mm at the 12-week interval. Conclusion: Following complete transection of the Achilles tendon, tendon retraction correlated with the density of myofibroblast expression within the tendon stump. Further research is needed to investigate the pathophysiology of these findings. (author)

  11. Magnetic resonance imaging appearance of the flexor carpi radialis tendon after harvest in ligamentous reconstruction tendon interposition arthroplasty

    International Nuclear Information System (INIS)

    Beall, Douglas P.; Fish, Jon R.; Ritchie, Eric R.; Tran, Hoang N.; Ingari, John V.; Campbell, Scot E.; Grayson, David E.; Sanders, Timothy G.; Mundis, Gregory; Lehman, Thomas P.

    2006-01-01

    To determine whether the post-harvest magnetic resonance (MR) imaging appearance of flexor carpi radialis (FCR) tendons, harvested during ligamentous reconstruction tendon interposition (LRTI) of the thumb carpometacarpal (CMC) joint arthroplasty, is consistent with tendon regeneration. Operative reports and patient medical records for all patients undergoing LRTI arthroplasty between 1995 and 2003 at our institution were reviewed. MR images of the patients' forearms and wrists were obtained and interpreted by two musculoskeletal radiologists. Using the flexor carpi ulnaris (FCU) tendon as an internal standard, the extent of FCR tendon regeneration was expressed as a percentage by dividing the volume of regenerated FCR tendon by the volume of the FCU tendon. Fourteen patients who had the full thickness of the FCR tendon harvested and who were available for MR imaging were identified and included in the study. At least partial regeneration of the FCR tendon occurred in 11 of the 14 patients (79%). Of these, 2 patients (14%), demonstrated complete, or nearly complete regeneration. Partial regeneration of the FCR tendon was seen in 9 of the 14 patients (64%). In 3 patients (21%), there was no appreciable regeneration of the FCR tendon. Among patients who underwent full-thickness harvest of the FCR tendon for LRTI arthroplasty of the first CMC joint, the follow-up MR imaging appearance of the flexor carpi radialis tendon was consistent with tendon regeneration in 79% of those examined. (orig.)

  12. FRP tendon anchorage in post-tensioned concrete structures

    DEFF Research Database (Denmark)

    Schmidt, Jacob Wittrup; Täljsten, Björn; Bennitz, Anders

    2008-01-01

    effective Young´s modulus and the high stress capacity in the linear elastic range of the material. The use of external tendons increases the requirements on the anchorage systems. This is in particular important when using un-bonded tendon systems, where the anchorage and deviators are the only force...... transfer points. The demand for high capacity anchorage tendons is fulfilled for steel tendons, but no competitive mechanical anchor has yet been developed for FRP tendon. A new small, reliable and more user friendly anchor has to be developed, before FRP tendons can be utilized with all of its capacity...

  13. Mechanical properties of the human Achilles tendon, in vivo

    DEFF Research Database (Denmark)

    Kongsgaard, M; Nielsen, C H; Hegnsvad, S

    2011-01-01

    Ultrasonography has been widely applied for in vivo measurements of tendon mechanical properties. Assessments of human Achilles tendon mechanical properties have received great interest. Achilles tendon injuries predominantly occur in the tendon region between the Achilles-soleus myotendinous...... junction and Achilles-calcaneus osteotendinous junction i.e. in the free Achilles tendon. However, there has been no adequate ultrasound based method for quantifying the mechanical properties of the free human Achilles tendon. This study aimed to: 1) examine the mechanical properties of the free human...

  14. Absence of musculocutaneous nerve and accessory head of biceps brachii: a case report

    Directory of Open Access Journals (Sweden)

    Arora L

    2005-01-01

    Full Text Available During dissection of a 55-year-old female cadaver, we observed that three nerve roots contributed to the formation of Median nerve in her right upper limb. Along with this variation, absence of Musculocutaneous nerve was noticed. The muscles of front of arm i.e. Biceps Brachii, Brachialis and Coracobrachialis received their nerve supply from Median nerve. The Lateral cutaneous nerve of forearm was derived from Median nerve. Also an accessory head of Biceps Brachii muscle was present in the right arm of the same cadaver. It is extremely important to be aware of these variations while planning a surgery in the region of axilla or arm as these nerves are more liable to be injured during operations.

  15. Optimal arm posture control and tendon traction forces of a coupled tendon-driven manipulator

    International Nuclear Information System (INIS)

    Ma, Shugen

    1997-01-01

    In this study, the optimum arm posture of a coupled tendon-driven multijoint manipulator arm (or CT Arm) at maximum payload output was derived and the corresponding tendon traction forces were also analyzed, during management of a heavy payload by the manipulator in a gravity environment. The CT Arm is special tendon traction transmission mechanism in which a pair of tendons used to drive a joint is pulled from base actuators via pulleys mounted on the base-side joints. This mechanism enables optimal utilization of the coupled drive function of tendon traction forces and thus enables the lightweight manipulator to exhibit large payload capability. The properties of the CT Arm mechanism are elucidated by the proposed optimal posture control scheme. Computer simulation was also executed to verify the validity of the proposed control scheme. (author)

  16. Highly Unusual Tendon Abnormality: Spontaneous Rupture of the Distal Iliopsoas Tendon

    Directory of Open Access Journals (Sweden)

    Gokcen Coban

    2014-06-01

    Full Text Available Iliopsoas tendon injuries are not common and usually occur due to avulsion of the iliopsoas tendon with detachment of the lesser trochanter, secondary to an athletic injury or trauma. In the absence of a trauma, avulsion of the lesser trochanter in an adult is regarded as a sign of metastatic disease until proven otherwise. Complete iliopsoas tendon tears have thus far only been described in elderly women, and without trauma or an underlying systemic disease, a hormonal basis may be a reason for the gender differences. In this article, we present an 87-year-old woman with spontaneous rupture of the left distal iliopsoas tendon unassociated with fracture of the lesser trochanter and in the absence of a recent trauma history. This elderly patient presented with acute groin pain and normal plain radiographs. Magnetic resonance imaging must be kept in mind as a modality of choice for identifying iliopsoas tendon abnormalities.

  17. Zircaloy sheathed thermocouples for PWR fuel rod temperature measurements

    International Nuclear Information System (INIS)

    Anderson, J.V.; Wesley, R.D.; Wilkins, S.C.

    1979-01-01

    Small diameter zircaloy sheathed thermocouples have been developed by EG and G Idaho, Inc., at the Idaho National Engineering Laboratory. Surface mounted thermocouples were developed to measure the temperature of zircaloy clad fuel rods used in the Thermal Fuels Behavior Program (TFBP), and embedded thermocouples were developed for use by the Loss-of-Fluid Test (LOFT) Program for support tests using zircaloy clad electrically heated nuclear fuel rod simulators. The first objective of this developmental effort was to produce zircaloy sheathed thermocouples to replace titanium sheathed thermocouples and thereby eliminate the long-term corrosion of the titanium-to-zircaloy attachment weld. The second objective was to reduce the sheath diameter to obtain faster thermal response and minimize cladding temperature disturbance due to thermocouple attachment

  18. significance of rice sheath photosynthesis: yield determination by c ...

    African Journals Online (AJOL)

    ACSS

    1State Key Laboratory of Hybrid Rice, Hunan Hybrid Rice Research Center, Changsha 410125, P.R. China. 2School of ... for contribution rates of sheath photosynthesis to economical yield. ..... related processes during ripening in rice plants.

  19. Malignant Peripheral Nerve Sheath Tumour of the Maxilla

    Directory of Open Access Journals (Sweden)

    Puja Sahai

    2014-01-01

    Full Text Available A 38-year-old man was diagnosed with malignant peripheral nerve sheath tumour of the maxilla. He was treated with total maxillectomy. Histopathological examination of the resected specimen revealed a close resection margin. The tumour was of high grade with an MIB-1 labelling index of almost 60%. At six weeks following the surgery, he developed local tumour relapse. The patient succumbed to the disease at five months from the time of diagnosis. The present report underlines the locally aggressive nature of malignant peripheral nerve sheath tumour of the maxilla which necessitates an early therapeutic intervention. A complete resection with clear margins is the most important prognostic factor for malignant peripheral nerve sheath tumour in the head and neck region. Adjuvant radiotherapy may be considered to improve the local control. Future research may demarcate the role of targeted therapy for patients with malignant peripheral nerve sheath tumour.

  20. Measure Guideline: Guidance on Taped Insulating Sheathing Drainage Planes

    Energy Technology Data Exchange (ETDEWEB)

    Grin, A. [Building Science Corporation, Somerville, MA (United States); Lstiburek, J. [Building Science Corporation, Somerville, MA (United States)

    2014-09-01

    The goal of this research is to provide durable and long-term water management solutions using exterior insulating sheathing as part of the water management system. It is possible to tape or seal the joints in insulating sheathing to create a drainage plane and even an air control layer. There exists the material durability component of the tape as well as the system durability component being the taped insulating sheathing as the drainage plane. This measure guideline provides best practice and product recommendations from the interviewed contractors and homebuilders who collectively have a vast amount of experience. Three significant issues were discussed with the group, which are required to make taped insulating sheathing a simple, long-term, and durable drainage plane: horizontal joints should be limited or eliminated wherever possible; where a horizontal joint exists use superior materials; and frequent installation inspection and regular trade training are required to maintain proper installation.

  1. Stability of the Tonks–Langmuir discharge pre-sheath

    Energy Technology Data Exchange (ETDEWEB)

    Tskhakaya, D. D. [Fusion@ÖAW, Institute of Applied Physics, TU Wien, Wiedner Hauptstraße 8-10, 1040 Vienna (Austria); Kos, L. [LECAD Laboratory, Faculty of Mechanical Engineering, University of Ljubljana, SI-1000 Ljubljana (Slovenia); Tskhakaya, D. [Fusion@ÖAW, Institute of Applied Physics, TU Wien, Wiedner Hauptstraße 8-10, 1040 Vienna (Austria); Institute for Theoretical Physics, University of Innsbruck, A-6020 Innsbruck (Austria)

    2016-03-15

    The article formulates the stability problem of the plasma sheath in the Tonks–Langmuir discharge. Using the kinetic description of the ion gas, i.e., the stability of the potential shape in the quasi-neutral pre-sheath regarding the high and low frequency, the perturbations are investigated. The electrons are assumed to be Maxwell–Boltzmann distributed. Regarding high-frequency perturbations, the pre-sheath is shown to be stable. The stability problem regarding low-frequency perturbations can be reduced to an analysis of the “diffusion like” equation, which results in the instability of the potential distribution in the pre-sheath. By means of the Particle in Cell simulations, also the nonlinear stage of low frequency oscillations is investigated. Comparing the figure obtained with the figure for linear stage, one can find obvious similarity in the spatial-temporal behavior of the potential.

  2. Reconstruction of scalar field theories realizing inflation consistent with the Planck and BICEP2 results

    Directory of Open Access Journals (Sweden)

    Kazuharu Bamba

    2014-10-01

    Full Text Available We reconstruct scalar field theories to realize inflation compatible with the BICEP2 result as well as the Planck. In particular, we examine the chaotic inflation model, natural (or axion inflation model, and an inflationary model with a hyperbolic inflaton potential. We perform an explicit approach to find out a scalar field model of inflation in which any observations can be explained in principle.

  3. Autoradiographic visualization of extrajunctional acetylcholine receptors in whole human biceps brachii muscle

    International Nuclear Information System (INIS)

    Askmark, H.; Gillberg, P.-G.; Aquilonius, S.-M.

    1985-01-01

    The morphological distribution of acetylcholine receptors in the whole biceps brachii muscle from a patient with amyotrophic lateral sclerosis (ALS) and from a control patient was studied by in vitro autoradiography with 3 H-alpha-bungarotoxin alphaBtx). In ALS, 3 H-alpha-Btx binding occurred over the entire muscle, while in the control case the binding was restricted to the motor end-plate region. (author)

  4. Biceps tenodesis is a viable option for salvage of failed SLAP repair.

    Science.gov (United States)

    Werner, Brian C; Pehlivan, Hakan C; Hart, Joseph M; Lyons, Matthew L; Gilmore, C Jan; Garrett, Cara B; Carson, Eric W; Diduch, David R; Miller, Mark D; Brockmeier, Stephen F

    2014-08-01

    Outcomes of arthroscopic superior labral anterior-posterior (SLAP) repairs have been well reported with generally favorable outcomes. Unfortunately, a percentage of patients remain dissatisfied or suffer further injury after SLAP repair and may seek additional treatment. The purpose of this study was to evaluate the surgical outcomes of biceps tenodesis for failed SLAP repairs. A retrospective review of all patients undergoing biceps tenodesis was completed. Inclusion criteria were previous SLAP repair and subsequent revision biceps tenodesis. Exclusion criteria were additional shoulder procedures including rotator cuff repair, instability procedures, and preoperative frozen shoulder. Objective outcomes were postoperative assessments with Constant score, American Shoulder and Elbow Surgeons score, Single Assessment Numeric Evaluation, Simple Shoulder Test, and Veterans RAND 36-Item Health Survey. Physical examination was conducted to determine postoperative range of motion and strength compared with the nonoperative shoulder. A cohort of 24 patients was identified, and of these, 17 patients (71%) completed the study at 2 years' follow-up. The average postoperative Constant score was 84.4; American Shoulder and Elbow Surgeons score, 75.5; Single Assessment Numeric Evaluation score, 73.1%; Simple Shoulder Test score, 9.2; and Veterans RAND 36-Item Health Survey score, 76.1. Postoperative range of motion of the operative shoulder returned to near that of the asymptomatic nonoperative shoulder. Workers' compensation status led to inferior results. Options for patients with a failed prior SLAP repair are limited. As a salvage operation for failed SLAP repair, biceps tenodesis serves the majority of patients well, with favorable outcomes by validated measures and excellent shoulder range of motion and elbow strength at 2 years' follow-up. Workers' compensation status may predispose patients to poorer outcomes. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board

  5. Properties of leaves particleboard for sheathing application

    Science.gov (United States)

    Nuryawan, Arif; Rahmawaty

    2018-03-01

    Manufacturing particleboard (PB) made of leaves was carried out to make non-structural building components, such as insulation, partition, wall, and sheathing. Raw materials used dry leaves originated from plantation (palm oil leaves) and forest plantation (magahony leaves). The adhesive used was interior type thermosetting commercial resins, namely 10% urea-formaldehyde (UF) based on oven dry leaves. Hardener used for UF resin was 1% and 3% ammonium chloride (NH4Cl) 20% (w/w), respectively. Technically, the target density of PB was 0.8 g/cm3 with the dimension’s size of (250 x 250 x 10) mm3. The pressure, temperature, and time of pressing of the hot press were 25 kgf/cm2, 120C, and 10 minutes, respectively. After conditioning for one week, the PB then was evaluated their physical and mechanical properties according to Japanese Industrial Standard (JIS) A 5908 (2003). Results of this work showed: 1) Both types of PB (palm oil and mahagony leaves) were feasible to be produced for non-structural applications; 2) Addition of hardener enhanced the physical and mechanical properties of PB; 3) It was recommended to enhance the performance of the PB by manipulation of the raw materials and the design.

  6. Axial sheath dynamics in a plasma focus

    International Nuclear Information System (INIS)

    Soliman, H.M.; El-Khalafawy, T.A.; Masoud, M.M.

    1990-01-01

    This paper presents the result of investigation with a 10 kJ Mather type plasma focus. It is operated in hydrogen gas at ambient pressure of 0.15--1 torr and charging voltage of 8--11 kV. Radial distribution of the current sheath density with axial distance has been estimated. Plasma rotation in the expansion chamber in the absence of external magnetic field has been detected. A plasma flare from the plasma focus region propagating in the radial direction has been observed. Streak photography shows two plasma streams flowing simultaneously out of the muzzle. The mean energy of the electron beam ejected from the pinch region of the focused plasma, was measured by retarding field analyzer to be 0.32 keV. The electron temperature of the plasma focus at peak compression was determined by measuring the X-ray intensity as a function of absorber thickness at a distance of 62 cm from the focus. The electron temperature has been found to 3 keV

  7. Cell Based Meniscal Repair Using an Aligned Bioactive Nanofibrous Sheath

    Science.gov (United States)

    2017-07-01

    to subsequently guide tissue regeneration , for example, by seeded tissue progenitor cells . To achieve this objective, the first step is to develop...AWARD NUMBER: W81XWH-15-1-0104 TITLE: Cell -Based Meniscal Repair Using an Aligned Bioactive Nanofibrous Sheath PRINCIPAL INVESTIGATOR...SUBTITLE 5a. CONTRACT NUMBER Cell -Based Meniscal Repair Using an Aligned Bioactive Nanofibrous Sheath 5b. GRANT NUMBER W81XWH-15-1-0104 5c. PROGRAM

  8. Composition of the sheath produced by the green alga Chlorella sorokiniana.

    Science.gov (United States)

    Watanabe, K; Imase, M; Sasaki, K; Ohmura, N; Saiki, H; Tanaka, H

    2006-05-01

    To investigate the chemical characterization of the mucilage sheath produced by Chlorella sorokiniana. Algal mucilage sheath was hydrolysed with NaOH, containing EDTA. The purity of the hydrolysed sheath was determined by an ATP assay. The composition of polysaccharide in the sheath was investigated by high-performance anion-exchange chromatography with pulsed amperometric detection. Sucrose, galacturonic acid, xylitol, inositol, ribose, mannose, arabinose, galactose, rhamnose and fructose were detected in the sheath as sugar components. Magnesium was detected in the sheath as a divalent cation using inductively coupled argon plasma. The sheath matrix also contained protein. It appears that the sheath is composed of sugars and metals. Mucilage sheath contains many kinds of saccharides that are produced as photosynthetic metabolites and divalent cations that are contained in the culture medium. This is the first report on chemical characterization of the sheath matrix produced by C. sorokiniana.

  9. Killing the straw man: Does BICEP prove inflation at the GUT scale?

    Energy Technology Data Exchange (ETDEWEB)

    Dent, James B. [Department of Physics, University of Louisiana at Lafayette, Lafayette, LA 70504 (United States); Krauss, Lawrence M. [Department of Physics and School of Earth and Space Exploration, Arizona State University, Tempe, AZ 85287 (United States); Mount Stromlo Observatory, Research School of Astronomy and Astrophysics, Australian National University, Weston, ACT, 2611 (Australia); Mathur, Harsh [Department of Physics, Case Western Reserve University, Cleveland, OH 44106-7079 (United States)

    2014-09-07

    The surprisingly large value of r, the ratio of power in tensor to scalar density perturbations in the CMB reported by the BICEP2 Collaboration, if confirmed, provides strong evidence for Inflation at the GUT scale. While the Inflationary signal remains the best motivated source, a large value of r alone would still allow for the possibility that a comparable gravitational wave background might result from a self ordering scalar field (SOSF) transition that takes place later at somewhat lower energy. We find that even without detailed considerations of the predicted BICEP signature of such a transition, simple existing limits on the isocurvature contribution to CMB anisotropies would definitively rule out a contribution of more than 5% to r≈0.2. We also present a general relation for the allowed fractional SOSF contribution to r as a function of the ultimate measured value of r. These results point strongly not only to an inflationary origin of the BICEP2 signal, if confirmed, but also to the fact that if the GUT scale is of order 10{sup 16} GeV then either the GUT transition happens before Inflation or the Inflationary transition and the GUT transition must be one and the same.

  10. Analysis of the Biceps Brachii Muscle by Varying the Arm Movement Level and Load Resistance Band

    Directory of Open Access Journals (Sweden)

    Nuradebah Burhan

    2017-01-01

    Full Text Available Biceps brachii muscle illness is one of the common physical disabilities that requires rehabilitation exercises in order to build up the strength of the muscle after surgery. It is also important to monitor the condition of the muscle during the rehabilitation exercise through electromyography (EMG signals. The purpose of this study was to analyse and investigate the selection of the best mother wavelet (MWT function and depth of the decomposition level in the wavelet denoising EMG signals through the discrete wavelet transform (DWT method at each decomposition level. In this experimental work, six healthy subjects comprised of males and females (26 ± 3.0 years and BMI of 22 ± 2.0 were selected as a reference for persons with the illness. The experiment was conducted for three sets of resistance band loads, namely, 5 kg, 9 kg, and 16 kg, as a force during the biceps brachii muscle contraction. Each subject was required to perform three levels of the arm angle positions (30°, 90°, and 150° for each set of resistance band load. The experimental results showed that the Daubechies5 (db5 was the most appropriate DWT method together with a 6-level decomposition with a soft heursure threshold for the biceps brachii EMG signal analysis.

  11. Analysis of the Biceps Brachii Muscle by Varying the Arm Movement Level and Load Resistance Band

    Science.gov (United States)

    Abdullah, Shahrum Shah; Jali, Mohd Hafiz

    2017-01-01

    Biceps brachii muscle illness is one of the common physical disabilities that requires rehabilitation exercises in order to build up the strength of the muscle after surgery. It is also important to monitor the condition of the muscle during the rehabilitation exercise through electromyography (EMG) signals. The purpose of this study was to analyse and investigate the selection of the best mother wavelet (MWT) function and depth of the decomposition level in the wavelet denoising EMG signals through the discrete wavelet transform (DWT) method at each decomposition level. In this experimental work, six healthy subjects comprised of males and females (26 ± 3.0 years and BMI of 22 ± 2.0) were selected as a reference for persons with the illness. The experiment was conducted for three sets of resistance band loads, namely, 5 kg, 9 kg, and 16 kg, as a force during the biceps brachii muscle contraction. Each subject was required to perform three levels of the arm angle positions (30°, 90°, and 150°) for each set of resistance band load. The experimental results showed that the Daubechies5 (db5) was the most appropriate DWT method together with a 6-level decomposition with a soft heursure threshold for the biceps brachii EMG signal analysis. PMID:29138687

  12. Killing the straw man: Does BICEP prove inflation at the GUT scale?

    International Nuclear Information System (INIS)

    Dent, James B.; Krauss, Lawrence M.; Mathur, Harsh

    2014-01-01

    The surprisingly large value of r, the ratio of power in tensor to scalar density perturbations in the CMB reported by the BICEP2 Collaboration, if confirmed, provides strong evidence for Inflation at the GUT scale. While the Inflationary signal remains the best motivated source, a large value of r alone would still allow for the possibility that a comparable gravitational wave background might result from a self ordering scalar field (SOSF) transition that takes place later at somewhat lower energy. We find that even without detailed considerations of the predicted BICEP signature of such a transition, simple existing limits on the isocurvature contribution to CMB anisotropies would definitively rule out a contribution of more than 5% to r≈0.2. We also present a general relation for the allowed fractional SOSF contribution to r as a function of the ultimate measured value of r. These results point strongly not only to an inflationary origin of the BICEP2 signal, if confirmed, but also to the fact that if the GUT scale is of order 10 16 GeV then either the GUT transition happens before Inflation or the Inflationary transition and the GUT transition must be one and the same.

  13. Steroid injection for painful shoulder: Usefulness of ultrasound-guided approach

    International Nuclear Information System (INIS)

    Lee, Min Hee

    2004-01-01

    To evaluate the efficacy of steroid injection into the subacromial bursa and biceps tendon sheath for painful shoulders and the usefulness of ultrasound-guided approach. Seventeen shoulders of twelve patients with shoulder pain and limited motion were included, and these patient were clinically diagnosed as a painful arc syndrome. Under ultrasound guidance, steroid injection was performed into the subacormial bursa (13 cases) and biceps tendon sheath (4 cases). In 7 cases, 1 mL of steroid was used while the remaining six patients received a mixture of 1 mL of steroid and 1 ml of lidocaine. Both shoulders of two patients received 0.5 mL of steroid. The location of needle and injection duration of fluid were continuously monitored, and complications such as leakage of steroid were recorded. Medical records were reviewed for the presence of pain relief and increasing range of motion following the injection. On ultrasonogram, the needle within the subacromial bursa and biceps tendon sheath was seen as a linear echogenic structure, and injected fluid was identified. There was neither the leakage of steroid injection nor any other complications. In 16 (94%) of 17 shoulders, there was decreased intensity of shoulder pain while increased range of motion was noted in three patients following the injection. Steroid injection into the subacormial bursa and biceps tendon sheath is effective in treating shoulder pain and limited range of motion of the shoulder, and ultrasound is useful guiding method.

  14. Studies of irradiated zircaloy fuel sheathing using XPS

    International Nuclear Information System (INIS)

    Chan, P.K.; Irving, K.G.; Hocking, W.H.; Duclos, A.M.; Gerwing, A.F.

    1995-01-01

    The preliminary results reported here support the hypothesis that CANLUB graphite coating reduces the rate at which oxygen can react with fuel sheathing. X-ray photoelectron spectroscopic (XPS) characterization of Zircaloy sheathing obtained from extended-burnup Bruce-type elements (BDL-406-XY (555 MW.h/kgU) and BDL-406-AAH (731 MW.h/kgU)) irradiated in NRU indicates that CANLUB may reduce fuel sheath oxidation, and hence that fission-liberated oxygen may remain in the fuel. Chemical shifts in the Zr 3d spectra suggest that a stoichiometric (ZrO 2 ) oxide film was formed only on Zircaloy in direct contact with fuel. Particulate fuel adhering to the sheath was also determined to be systematically more oxidized on surfaces with CANLUB than on those without it. The unique association of tin on sheathing specimens with the non-CANLUB-coated specimens might also suggest that the tin had segregated from the sheathing. It must be emphasized that further experiments are required to better define the effect of CANLUB on fuel oxidation. (author). 14 refs., 1 tab., 3 figs

  15. Effects of emitted electron temperature on the plasma sheath

    International Nuclear Information System (INIS)

    Sheehan, J. P.; Kaganovich, I. D.; Wang, H.; Raitses, Y.; Sydorenko, D.; Hershkowitz, N.

    2014-01-01

    It has long been known that electron emission from a surface significantly affects the sheath surrounding that surface. Typical fluid theory of a planar sheath with emitted electrons assumes that the plasma electrons follow the Boltzmann relation and the emitted electrons are emitted with zero energy and predicts a potential drop of 1.03T e /e across the sheath in the floating condition. By considering the modified velocity distribution function caused by plasma electrons lost to the wall and the half-Maxwellian distribution of the emitted electrons, it is shown that ratio of plasma electron temperature to emitted electron temperature significantly affects the sheath potential when the plasma electron temperature is within an order of magnitude of the emitted electron temperature. When the plasma electron temperature equals the emitted electron temperature the emissive sheath potential goes to zero. One dimensional particle-in-cell simulations corroborate the predictions made by this theory. The effects of the addition of a monoenergetic electron beam to the Maxwellian plasma electrons were explored, showing that the emissive sheath potential is close to the beam energy only when the emitted electron flux is less than the beam flux

  16. Plasma Sheath Behavior in a Coaxial Discharge Device

    International Nuclear Information System (INIS)

    EL-Aragi, G.; Soliman, H.M.; Masoud, M.M.

    2001-01-01

    The behavior of the plasma sheath has been studied experimentally and theoretically for 3 kJ coaxial discharge device. The discharge takes place in argon gas with pressure of 0.8 mbar. The experiments are conducted with a 10 kV bank charging voltage, which corresponds to 110 kA peak discharge current with time period of 34 μs. The experimental investigations have been studied using a magnetic probes and a miniature Rogowsky coil. A snowplough model is used to drive an analytical solution of the plasma sheath behavior in axial direction. Measurements of radial distribution of plasma sheath current density J r at the muzzle, show that J r has the following relation, J r is proportional to r -1.1 . From the experimental results and theoretical calculations of axial distribution of azimuthal magnetic field induction and plasma sheath velocity, the inclination angle between the normal of the plasma sheath with the axial distance at any axial position is evaluated and it has approximately a constant value for most axial distances. Also, the axial motion of plasma sheath acceleration is estimated experimentally a max = 0.13 x 10 12 ' cm / s 2 at z = 11 cm and from theoretical calculations a max = 0.15 x 10 12 cm/ s 2 at max z = 1.6 cm. A comparison of the experimental results with the theoretical calculations, under the assumption of the snowplough model are not in agreement. (author)

  17. Studies of irradiated zircaloy fuel sheathing using XPS

    Energy Technology Data Exchange (ETDEWEB)

    Chan, P K; Irving, K G [Atomic Energy of Canada Ltd., Chalk River, ON (Canada); Hocking, W H; Duclos, A M; Gerwing, A F [Atomic Energy of Canada Ltd., Pinawa, MB (Canada). Whiteshell Labs.

    1996-12-31

    The preliminary results reported here support the hypothesis that CANLUB graphite coating reduces the rate at which oxygen can react with fuel sheathing. X-ray photoelectron spectroscopic (XPS) characterization of Zircaloy sheathing obtained from extended-burnup Bruce-type elements (BDL-406-XY (555 MW.h/kgU) and BDL-406-AAH (731 MW.h/kgU)) irradiated in NRU indicates that CANLUB may reduce fuel sheath oxidation, and hence that fission-liberated oxygen may remain in the fuel. Chemical shifts in the Zr 3d spectra suggest that a stoichiometric (ZrO{sub 2}) oxide film was formed only on Zircaloy in direct contact with fuel. Particulate fuel adhering to the sheath was also determined to be systematically more oxidized on surfaces with CANLUB than on those without it. The unique association of tin on sheathing specimens with the non-CANLUB-coated specimens might also suggest that the tin had segregated from the sheathing. It must be emphasized that further experiments are required to better define the effect of CANLUB on fuel oxidation. (author). 14 refs., 1 tab., 3 figs.

  18. Dynamic sheath studies in plasma source ion implantation

    International Nuclear Information System (INIS)

    Schever, J.T.; Shamim, M.; Conrad, J.R.

    1990-01-01

    Plasma Source Ion Implantation (PSII) is a non-line-of-sight method for materials processing in which a target is immersed in a plasma and pulse biased to a high negative voltage (∼ 50 kV). A model of the dynamic sheath which forms under these conditions has been developed and applied to planar, cylindrical and spherical geometries. This model assumes that the transient sheath obeys the Child-Langmuir law for space charge limited emission at each instant during the propagation. Ions uncovered by the propagating sheath edge supply the space charge limited current. This yields an equation relating sheath edge velocity to position, which can be integrated to obtain the sheath edge position as a function of time. The same procedure used in cylindrical and spherical geometry results in a similar equation which must be integrated numerically. Comparison of results of experimental measurements, our model and simulation will be presented for the dynamic sheath edge position and target current waveform. Measurements of implanted dose uniformity of wedge shaped targets are also presented

  19. Multimodal imaging in neurofibromatosis type 1-associated nerve sheath tumors

    International Nuclear Information System (INIS)

    Salamon, J.; Adam, G.; Mautner, V.F.; Derlin, T.

    2015-01-01

    Neurofibromatosis type 1 (NF1) is a neurogenetic disorder. Individuals with NF1 may develop a variety of benign and malignant tumors of which peripheral nerve sheath tumors represent the most frequent entity. Plexiform neurofibromas may demonstrate a locally destructive growth pattern, may cause severe symptoms and may undergo malignant transformation into malignant peripheral nerve sheath tumors (MPNSTs). Whole-body magnetic resonance imaging (MRI) represents the reference standard for detection of soft tissue tumors in NF1. It allows for identification of individuals with plexiform neurofibromas, for assessment of local tumor extent, and for evaluation of whole-body tumor burden on T2-weighted imaging. Multiparametric MRI may provide a comprehensive characterization of different tissue properties of peripheral nerve sheath tumors, and may identify parameters associated with malignant transformation. Due to the absence of any radiation exposure, whole-body MRI may be used for serial follow-up of individuals with plexiform neurofibromas. 18 F-fluorodeoxyglucose positron-emission-tomography (FDG PET/CT) allows a highly sensitive and specific detection of MPNST, and should be used in case of potential malignant transformation of a peripheral nerve sheath tumor. PET/CT provides a sensitive whole-body tumor staging. The use of contrast-enhanced CT for diagnosis of peripheral nerve sheath tumors is limited to special indications. To obtain the most precise readings, optimized examination protocols and dedicated radiologists and nuclear medicine physicians familiar with the complex and variable morphologies of peripheral nerve sheath tumors are required.

  20. Atomic Structure of Type VI Contractile Sheath from Pseudomonas aeruginosa.

    Science.gov (United States)

    Salih, Osman; He, Shaoda; Planamente, Sara; Stach, Lasse; MacDonald, James T; Manoli, Eleni; Scheres, Sjors H W; Filloux, Alain; Freemont, Paul S

    2018-02-06

    Pseudomonas aeruginosa has three type VI secretion systems (T6SSs), H1-, H2-, and H3-T6SS, each belonging to a distinct group. The two T6SS components, TssB/VipA and TssC/VipB, assemble to form tubules that conserve structural/functional homology with tail sheaths of contractile bacteriophages and pyocins. Here, we used cryoelectron microscopy to solve the structure of the H1-T6SS P. aeruginosa TssB1C1 sheath at 3.3 Å resolution. Our structure allowed us to resolve some features of the T6SS sheath that were not resolved in the Vibrio cholerae VipAB and Francisella tularensis IglAB structures. Comparison with sheath structures from other contractile machines, including T4 phage and R-type pyocins, provides a better understanding of how these systems have conserved similar functions/mechanisms despite evolution. We used the P. aeruginosa R2 pyocin as a structural template to build an atomic model of the TssB1C1 sheath in its extended conformation, allowing us to propose a coiled-spring-like mechanism for T6SS sheath contraction. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  1. Simulations of rf-driven sheath formation in two dimensions

    International Nuclear Information System (INIS)

    Riyopoulos, S.; Grossmann, W.; Drobot, A.; Kress, M.

    1992-01-01

    The results from two-dimensional particle simulations of sheath formation around periodic metal arrays placed inside magnetized plasmas and driven by oscillating voltages are reported. The main goal is the modeling of the plasma interaction with the Faraday bars surrounding the antennas during ion cyclotron tokamak heating. The study of the time-averaged potentials shows that the two-dimensional sheath structure depends on both the sheath length-to-thickness ratio and the inclination of the magnetic lines. The equipotential surfaces form closed, nested cells between adjacent bars. When the magnetic lines are nearly perpendicular to the potential gradients, the ion motion is dominated by the ExB drift, and ion streamlines form vortices around the equipotentials. At larger inclinations of the magnetic lines, the flow decouples from the equipotentials and ion transport is mainly along the potential gradients. The critical angle for the transition from vortex circulation to field aligned flow is computed. The effects of the cross-field ion transport on the sheath properties are discussed. It is shown that the sheath length and the magnetic line inclination affect the sheath scaling in the two-dimensional case. The one-dimensional theory results are recovered in the limit of high length-to-thickness ratio and large inclination of the magnetic lines

  2. Analytical expression for sheath edge around corner cathodes

    International Nuclear Information System (INIS)

    Sheridan, T E

    2009-01-01

    A simple analytical expression for the position of the sheath edge around a two-dimensional corner cathode with included angle θ c has been discovered. This expression is valid for weakly collisional sheaths in the Child-Langmuir regime φ c >> kT e /e, where -φ c e is the electron temperature. In polar coordinates (r, θ), the sheath edge is given by (r/s 0 )sin[πθ/(2π - θ c )] = [π/(2π - θ c )] where s 0 is the planar sheath width far from the vertex of the corner. This result is verified by comparison with previous numerical solutions (Watterson P A 1989 J. Phys. D: Appl. Phys. 22 1300) for the knife edge (θ c = 0) and convex square corner (θ c = π/2). The observed agreement suggests that this expression gives the sheath edge for all corner angles, both concave and convex. The utility of this result is demonstrated by computing the full sheath solution for a knife-edge cathode with φ c = 100kT e /e.

  3. Postoperative US of leg tendon reconstruction

    International Nuclear Information System (INIS)

    Draghi, F.; Calliada, F.; Fulle, I.; Madonia, L.; Bottinelli, O.; Campani, R.

    1999-01-01

    The role of ultrasound (US) in the postoperative assessment of tendon reconstruction is not clearly defined and there is non systematic arrangement of US patterns. The authors examined 34 patients submitted to surgery or conservative treatment for total/partial tear or musculotendinous detachment of patellar or Achilles tendon in the last 5 years. All patients underwent physical and US examinations. The surgical tendon exhibited the same US patterns in 23/28 patients: it was markedly enlarged (three-/fourfold the normal diameter) and more rounded, with inhomogeneous and hypoechoic appearance not only at the tear/surgical site but also above and below it, for some cm. Small hyperechoic images, mainly dots, were seen in 19 cases, which were referable to small calcifications and stitches. More and larger calcifications were found in 8 patients, where they were associated with anechoic degeneration areas. Color Doppler US showed moderate or strong hypervascularization around the tear in the first months post injury. US patterns did not correlate with physical findings, but color Doppler patterns did. In 6 cases of musculotendinous detachment submitted to conservative treatment, US showed enlargement and hypoechogenicity in the injury site only, with no involvement of the remaining tendon. US was also used to time and guide drainage of perilesional hematomas, which were often quite large. US is the method of choice in the postoperative follow-up of tendon tears and musculotendinous detachments because it shows abnormal signs which are missed at clinics and provides additional information needed for treatment planning [it

  4. Genomic and Expression Profiling of Benign and Malignant Nerve Sheath Profiling of Benign and Malignant Nerve Sheath

    Science.gov (United States)

    2007-05-01

    Benign and Malignant Nerve Sheath Tumors in Neurofibromatosis Patients PRINCIPAL INVESTIGATOR: Matt van de Rijn, M.D., Ph.D. Torsten...Annual 3. DATES COVERED 1 May 2006 –30 Apr 2007 4. TITLE AND SUBTITLE 5a. CONTRACT NUMBER Genomic and Expression Profiling of Benign and Malignant Nerve...Award Number: DAMD17-03-1-0297 Title: Genomic and Expression Profiling of Benign and Malignant Nerve Sheath Tumors in Neurofibromatosis

  5. management of open achilles tendon injury: primary repair and early ...

    African Journals Online (AJOL)

    is attributable to increase in both competitive and recreational sports. In most of the literature written on Achilles tendon injuries there were rarely any information about open Achilles tendon ... The most common aetiology was motorbike spoke.

  6. Robot Arm with Tendon Connector Plate and Linear Actuator

    Science.gov (United States)

    Ihrke, Chris A. (Inventor); Diftler, Myron A. (Inventor); Bridgwater, Lyndon (Inventor); Nguyen, Vienny (Inventor); Millerman, Alexander (Inventor)

    2014-01-01

    A robotic system includes a tendon-driven end effector, a linear actuator, a flexible tendon, and a plate assembly. The linear actuator assembly has a servo motor and a drive mechanism, the latter of which translates linearly with respect to a drive axis of the servo motor in response to output torque from the servo motor. The tendon connects to the end effector and drive mechanism. The plate assembly is disposed between the linear actuator assembly and the tendon-driven end effector and includes first and second plates. The first plate has a first side that defines a boss with a center opening. The second plate defines an accurate through-slot having tendon guide channels. The first plate defines a through passage for the tendon between the center opening and a second side of the first plate. A looped end of the flexible tendon is received within the tendon guide channels.

  7. BICEP2, Planck, spinorial space-time, pre-Big Bang.

    Directory of Open Access Journals (Sweden)

    Gonzalez-Mestres Luis

    2015-01-01

    Full Text Available The field of Cosmology is currently undergoing a positive and constructive crisis. Controversies concerning inflation are not really new. But after the 2013-2014 Planck and BICEP2 announcements, and the more recent joint analysis by Planck, BICEP2 and the Keck Array (PBKA, the basic issues can involve more direct links between the Mathematical Physics aspects of cosmological patterns and the interpretation of experimental results. Open questions and new ideas on the foundations of Cosmology can emerge, while future experimental and observational programs look very promising. The BICEP2 result reporting an excess of B-mode polarization signal of the cosmic microwave background (CMB radiation was initially presented as a signature of primordial gravitational waves from cosmic inflation. But polarized dust emission can be at the origin of such a signal, and the evidence claimed by BICEP2 is no longer secure after the PBKA analysis. Furthermore, even assuming that significant CMB B-mode polarization has indeed been generated by the early Universe, its theoretical and cosmological interpretation would be far from obvious. Inflationary gravitational waves are not the only possible source of primordial CMB B-modes. Alternative cosmologies such as pre-Big Bang patterns and the spinorial space-time (SST we introduced in 1996-97 can naturally produce this polarization. Furthermore, the SST automatically generates for each comoving observer a local privileged space direction (PSD whose existence may have been confirmed by Planck data. If such a PSD exists, vector perturbations have most likely been strong in the early Universe and may have produced CMB B-modes. Pre-Big Bang cosmologies can also generate gravitational waves in the early Universe without inflation. After briefly describing detectors devoted to the study of the CMB polarization, we discuss the situation emerging from BICEP2 results, Planck results and the PBKA analysis. In particular, we

  8. Biceps brachii long head overactivity associated with elbow flexion contracture in brachial plexus birth palsy.

    Science.gov (United States)

    Sheffler, Lindsey C; Lattanza, Lisa; Sison-Williamson, Mitell; James, Michelle A

    2012-02-15

    The etiology of elbow flexion contracture in children with brachial plexus birth palsy remains unclear. We hypothesized that the long head of the biceps brachii muscle assists with shoulder stabilization in children with brachial plexus birth palsy and that overactivity of the long head during elbow and shoulder activity is associated with an elbow flexion contracture. Twenty-one patients with brachial plexus birth palsy-associated elbow flexion contracture underwent testing with surface electromyography. Twelve patients underwent repeat testing with fine-wire electromyography. Surface electrodes were placed on the muscle belly, and fine-wire electrodes were inserted bilaterally into the long and short heads of the biceps brachii. Patients were asked to perform four upper extremity tasks: elbow flexion-extension, hand to head, high reach, and overhead ball throw. The mean duration of muscle activity in the affected limb was compared with that in the contralateral, unaffected limb, which was used as a control. Three-dimensional motion analysis, surface dynamometry, and validated function measures were used to evaluate upper extremity kinematics, elbow flexor-extensor muscle imbalance, and function. The mean activity duration of the long head of the biceps brachii muscle was significantly higher in the affected limb as compared with the contralateral, unaffected limb during hand-to-head tasks (p = 0.02) and high-reach tasks (p = 0.03). No significant differences in mean activity duration were observed for the short head of the biceps brachii muscle between the affected and unaffected limbs. Isometric strength of elbow flexion was not significantly higher than that of elbow extension in the affected limb (p = 0.11). Overactivity of the long head of the biceps brachii muscle is associated with and may contribute to the development of elbow flexion contracture in children with brachial plexus birth palsy. Elbow flexion contracture may not be associated with an elbow

  9. Rehabilitation of the elbow extension with motor imagery in a patient with quadriplegia after tendon transfer.

    Science.gov (United States)

    Grangeon, Murielle; Guillot, Aymeric; Sancho, Pierre-Olivier; Picot, Marion; Revol, Patrice; Rode, Gilles; Collet, Christian

    2010-07-01

    To test the effect of a postsurgical motor imagery program in the rehabilitation of a patient with quadriplegia. Crossover design with kinematic analysis. Rehabilitation Hospital of Lyon. Study approved by the local Human Research Ethics Committee. C6-level injured patient (American Spinal Injury Association Impairment Scale grade A) with no voluntary elbow extension (triceps brachialis score 1). The surgical procedure was to transfer the distal insertion of the biceps brachii onto the triceps tendon of both arms. The postsurgical intervention on the left arm included 10 sessions of physical rehabilitation followed by 10 motor imagery sessions of 30 minutes each. The patient underwent 5 sessions a week during 2 consecutive weeks. The motor imagery content included mental representations based on elbow extension involved in goal-directed movements. The rehabilitation period of the right arm was reversed, with motor imagery performed first, followed by physical therapy. The kinematics of upper-limb movements was recorded (movement time and variability) before and after each type of rehabilitation period. A long-term retention test was performed 1 month later. Motor imagery training enhanced motor recovery by reducing hand trajectory variability-that is, improving smoothness. Motor performance then remained stable over 1 month. Motor imagery improved motor recovery when associated with physical therapy, with motor performance remaining stable over the 1-month period. We concluded that motor imagery should be successfully associated with classic rehabilitation procedure after tendon transfer. Physical sessions may thus be shortened if too stressful or painful. Copyright 2010 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  10. Partial tear of the quadriceps tendon in a child

    International Nuclear Information System (INIS)

    Khanna, Geetika; El-Khoury, George

    2008-01-01

    We present a case of partial rupture of the quadriceps tendon in an 8-year-old girl. This is one of the youngest patients reported with a quadriceps tendon rupture, an entity seen predominantly in middle-aged people. The strength of the muscle tendon unit in a child makes tendon injuries extremely unusual as compared to apophyseal avulsions. The MR imaging findings of this unusual pediatric injury are illustrated. (orig.)

  11. Calcaneal tendon: imaging findings; Tendao calcaneo: avaliacao por imagem

    Energy Technology Data Exchange (ETDEWEB)

    Montandon, Cristiano; Fonseca, Cristiano Rezio; Montandon Junior, Marcelo Eustaquio [Colegio Brasileiro de Radiologia e Diagnostico por Imagem, Sao Paulo, SP (Brazil)]. E-mail: crismontandon@hotmail.com; Lobo, Leonardo Valadares; Ribeiro, Flavia Aparecida de Souza; Teixeira, Kim-Ir-Sen Santos [Goias Univ., Goiania, GO (Brazil). Hospital de Clinicas. Dept. de Diagnostico por Imagem e Anatomia Patologica

    2003-12-01

    We reviewed the radiological and clinical features of 23 patients with calcaneal tendon diseases, who were submitted to ultrasound or magnetic resonance imaging. The objective of this study was to characterize the lesions for a precise diagnosis of calcaneal tendon injuries. A wide range of calcaneal tendon diseases include degenerative lesions, inflammation of the peritendinous tissue such as peritendinitis and bursitis, and rupture. Imaging methods are essential in the diagnosis, treatment and follow-up of calcaneal tendon diseases. (author)

  12. MRI in flexor tendon rupture after collagenase injection

    International Nuclear Information System (INIS)

    Khurana, Shruti; Wadhwa, Vibhor; Chhabra, Avneesh; Amirlak, Bardia

    2017-01-01

    Flexor tendon rupture is an unusual complication following collagenase injection to relieve contractures. These patients require a close follow-up and in the event of tendon rupture, a decision has to be made whether to repair the tendon or manage the complication conservatively. The authors report the utility of MRI in the prognostication and management of a patient with Dupuytren's contracture, who underwent collagenase injection and subsequently developed flexor digitorum profundus tendon rupture. (orig.)

  13. p38 MAPK signaling in postnatal tendon growth and remodeling.

    Directory of Open Access Journals (Sweden)

    Andrew J Schwartz

    Full Text Available Tendon is a dynamic tissue whose structure and function is influenced by mechanical loading, but little is known about the fundamental mechanisms that regulate tendon growth and remodeling in vivo. Data from cultured tendon fibroblasts indicated that the p38 MAPK pathway plays an important role in tendon fibroblast proliferation and collagen synthesis in vitro. To gain greater insight into the mechanisms of tendon growth, and explore the role of p38 MAPK signaling in this process, we tested the hypotheses that inducing plantaris tendon growth through the ablation of the synergist Achilles tendon would result in rapid expansion of a neotendon matrix surrounding the original tendon, and that treatment with the p38 MAPK inhibitor SB203580 would prevent this growth. Rats were treated with vehicle or SB203580, and subjected to synergist ablation by bilateral tenectomy of the Achilles tendon. Changes in histological and biochemical properties of plantaris tendons were analyzed 3, 7, or 28 days after overload, and comparisons were made to non-overloaded animals. By 28 days after overload, tendon mass had increased by 30% compared to non-overloaded samples, and cross-sectional area (CSA increased by around 50%, with most of the change occurring in the neotendon. The expansion in CSA initially occurred through the synthesis of a hyaluronic acid rich matrix that was progressively replaced with mature collagen. Pericytes were present in areas of active tendon growth, but never in the original tendon ECM. Inhibition of p38 MAPK resulted in a profound decrease in IL6 expression, and had a modest effect on the expression of other ECM and cell proliferation genes, but had a negligible impact on overall tendon growth. The combined results from this study provided novel insights into tendon mechanobiology, and suggest that p38 MAPK signaling does not appear to be necessary for tendon growth in vivo.

  14. MRI in flexor tendon rupture after collagenase injection

    Energy Technology Data Exchange (ETDEWEB)

    Khurana, Shruti [Lady Hardinge Medical College, New Delhi (India); Wadhwa, Vibhor [University of Arkansas for Medical Sciences, Little Rock, AR (United States); Chhabra, Avneesh [UT Southwestern Medical Center, Dallas, TX (United States); Johns Hopkins University, Baltimore, MD (United States); Amirlak, Bardia [UT Southwestern Medical Center, Dallas, TX (United States)

    2017-02-15

    Flexor tendon rupture is an unusual complication following collagenase injection to relieve contractures. These patients require a close follow-up and in the event of tendon rupture, a decision has to be made whether to repair the tendon or manage the complication conservatively. The authors report the utility of MRI in the prognostication and management of a patient with Dupuytren's contracture, who underwent collagenase injection and subsequently developed flexor digitorum profundus tendon rupture. (orig.)

  15. PERONEAL TENDON LESIONS IN ATHLETES (REVIEW

    Directory of Open Access Journals (Sweden)

    E. E. Achkasov

    2016-01-01

    Full Text Available The authors analyzed scientific literature in respect of various issues in treatment of athletes with peroneal muscles lesions starting from 1987 till 2016. Key search and publications selection was made in PubMed and russian national electronic scientific library eLIBRARY. Peroneal tendons pathology is not the major but the underestimated cause of pain in lateral and hindfoot as well as of foot dysfunction which is difficult to distinguish from lesions of lateral ligaments of the ankle joint. Untreated lesions of peroneal tendons can result in chronic ankle pain and significant functional disorders. The purpose of the present paper is to improve the current comprehension of anatomy, to identify factors contributing to pathology, to perform diagnostic evaluation of peroneal tendons and to review current treatment options of such lesions.

  16. Triple Achilles Tendon Rupture: Case Report.

    Science.gov (United States)

    Saxena, Amol; Hofer, Deann

    We present a case report with 1-year follow-up data of a 57-year-old male soccer referee who had sustained an acute triple Achilles tendon rupture injury during a game. His triple Achilles tendon rupture consisted of a rupture of the proximal watershed region, a rupture of the main body (mid-watershed area), and an avulsion-type rupture of insertional calcific tendinosis. The patient was treated surgically with primary repair of the tendon, including tenodesis with anchors. Postoperative treatment included non-weightbearing for 4 weeks and protected weightbearing until 10 weeks postoperative, followed by formal physical therapy, which incorporated an "antigravity" treadmill. The patient was able to return to full activity after 26 weeks, including running and refereeing, without limitations. Copyright © 2017 The American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  17. Lateral force transmission between human tendon fascicles

    DEFF Research Database (Denmark)

    Haraldsson, Bjarki T; Aagaard, Per; Qvortrup, Klaus

    2008-01-01

    Whether adjacent collagen fascicles transmit force in parallel is unknown. The purpose of the present study was to examine the magnitude of lateral force transmission between adjacent collagen fascicles from the human patellar and Achilles tendon. From each sample two adjacent strands of fascicles...... was transversally cut while the other fascicle and the fascicular membrane were kept intact. Cycle 3: both fascicles were cut in opposite ends while the fascicular membrane was left intact. A decline in peak force of 45% and 55% from cycle 1 to cycle 2, and 93% and 92% from cycle 2 to cycle 3 was observed...... in the patellar and Achilles tendon fascicles, respectively. A decline in stiffness of 39% and 60% from cycle 1 to cycle 2, and of 93% and 100% from cycle 2 to cycle 3 was observed in the patellar and Achilles tendon fascicles, respectively. The present data demonstrate that lateral force transmission between...

  18. Flexor digitorum profundus tendon anatomy in the forearm

    Directory of Open Access Journals (Sweden)

    Teoman Dogan

    2012-04-01

    Methods: We used 11 forearms belonging to cadavers and fixed with formaldehyde. The forearms numbered 1, 2, 8, 9, 10, 11 were the left and right arms of the same cadavers. Those numbered 3, 4, 5, 6, 7 belonged to different cadavers. Dissections were made by using the atraumatic surgical technique. The tendons were studied to identify the structure and number of the fibers forming them. Results: The presence of a large common tendon was found in 10 of the 11 forearms. In 4 of these, the common tendon included the tendons of all four fingers. While the common tendon included 3 fingers in four forearms, it only included tendons belonging to 2 fingers in two forearms. It was not possible in one forearm to separate the common tendon into its fibers. In another forearm, tendons belonging to each digit were separate and independent starting at the muscle-tendon junction to the attachment points. Conclusion: The majority of the cadaver forearms used in the study displayed a single large FDP tendon in the zone between the muscle-tendon joint to the carpal tunnel entry prior to being distributed into each index. This anatomical feature should be considered in choosing materials and surgical technique for Zone V FDP tendon injuries, as well as in planning the rehabilitation process. [Hand Microsurg 2012; 1(1.000: 25-29

  19. Bilateral spontaneous rupture of flexor digitorum profundus tendons.

    LENUS (Irish Health Repository)

    O'Sullivan, S T

    2012-02-03

    Spontaneous tendon rupture is an unusual condition usually associated with underlying disease processes such as rheumatoid arthritis, chronic renal failure or bony abnormalities of the hand. We report a case of spontaneous, non-concurrent bilateral rupture of flexor profundus tendons in an otherwise healthy individual. Treatment was successful and consisted of a two-stage reconstruction of the ruptured tendon.

  20. Ultrasound diagnostics of muscle and tendon injuries

    Directory of Open Access Journals (Sweden)

    Stević Ruža

    2009-01-01

    Full Text Available Introduction. Sonography is a useful technique for the investigation of a number of musculoskeletal disorders. The most common indication for ultrasonography of muscles and tendons is the diagnosis of traumatic lesions, distinguishing them from other disorders and follow-up of healing process. Objective. The purpose of this paper is to show the importance of ultrasound in the diagnosis of muscle and tendon injuries. Methods. The study included 170 patients (148 male and 22 female, mean age 29.6 years (range 14-60 years. All examinations were performed by linear transducer of 7.5-10 MHz, with longitudinal and transverse scanning. Ultrasound examination followed physical examination. Results. Traumatic lesions of muscles were diagnosed in 113 patients (66.7% and tendon injuries in 57 cases (33.2%. The muscle changes detected by ultrasonography were the following: 70 (61.9% partial and two (1.76% complete ruptures, 22 (19.46% haematoma, 9 (7.96% strains grade I, 4 fibroses and 4 ossifying myositis 4 (3.5%, respectively. Complications of muscle injuries were diagnosed in two cases, a muscular hernia and an arteriovenous fistula. Among tendon injuries, 21 (33.8% ruptures and 36 (66.1% tendinitis were diagnosed. Accompanying effusion in the bursa of patients with tendon injuries was found in 9 cases. Conclusion. Ultrasonography allowed visualization and objective assessment of the type and the extent of traumatic pathomorphological changes of muscles and tendons. Such diagnostic possibilities of ultrasonography are especially important in the choice of appropriate therapy.

  1. Spontaneous Achilles tendon rupture in alkaptonuria

    Directory of Open Access Journals (Sweden)

    Omar A. Alajoulin

    2015-12-01

    Full Text Available Alkaptonuria (AKU is a rare inborn metabolic disease characterized by accumulation of homogentisic acid (HGA. Excretion of HGA in urine causes darkening of urine and its deposition in connective tissues causes dark pigmentation (ochronosis, early degeneration of articular cartilage, weakening of the tendons, and subsequent rupture. In this case report, we present a rare case of a patient presented with unilateral spontaneous rupture of Achilles tendon due to AKU. The patient developed most of the orthopedic manifestations of the disease earlier than typical presentations. Alkaptonuria patients should avoid strenuous exercises and foot straining especially in patients developing early orthopedic manifestations.

  2. Spontaneous Achilles tendon rupture in alkaptonuria.

    Science.gov (United States)

    Alajoulin, Omar A; Alsbou, Mohammed S; Ja'afreh, Somayya O; Kalbouneh, Heba M

    2015-12-01

    Alkaptonuria (AKU) is a rare inborn metabolic disease characterized by accumulation of homogentisic acid (HGA). Excretion of HGA in urine causes darkening of urine and its deposition in connective tissues causes dark pigmentation (ochronosis), early degeneration of articular cartilage, weakening of the tendons, and subsequent rupture. In this case report, we present a rare case of a patient presented with unilateral spontaneous rupture of Achilles tendon due to AKU. The patient developed most of the orthopedic manifestations of the disease earlier than typical presentations. Alkaptonuria patients should avoid strenuous exercises and foot straining especially in patients developing early orthopedic manifestations.

  3. [Development of Achilles tendon rupture in skiing].

    Science.gov (United States)

    Suckert, K; Benedetto, K P; Vogel, A

    1983-06-01

    This is an analysis of decline of rupture of the Achilles tendon in skiing while there is a steady increase of skiing injuries. Three groups, equipped with three different types of ski boots were observed once on a plane slope on the other hand on a bump track. The simultaneous size of angle of knee and ankle was measured by telemetry. The high plastic ski boot, which obstructs the ankle forward and lateral is apart from the rise of heel in the boot, the safety binding and the new skiing style the main reason for decline of rupture of the Achilles tendon in skiing.

  4. The Child-Langmuir law and analytical theory of collisionless to collision-dominated sheaths

    International Nuclear Information System (INIS)

    Benilov, M S

    2009-01-01

    This paper is concerned with summarizing simple analytical models of space-charge sheaths and tracing their relation to the Child-Langmuir model of an ion sheath. The topics discussed include the Child-Langmuir law and model of a collisionless ion sheath, the Mott-Gurney law and model of a collision-dominated ion sheath, the Bohm model of a collisionless ion-electron sheath, the Su-Lam-Cohen model of a collision-dominated ion-electron sheath, ion sheaths with arbitrary collisionality, high-accuracy boundary conditions for the Child-Langmuir and Mott-Gurney models of an ion sheath and the mathematical sense of Child-Langmuir type models of an ion sheath from the point of view of modern theoretical physics.

  5. Behavior of collisional sheath in electronegative plasma with q-nonextensive electron distribution

    Science.gov (United States)

    Borgohain, Dima Rani; Saharia, K.

    2018-03-01

    Electronegative plasma sheath is addressed in a collisional unmagnetized plasma consisting of q-nonextensive electrons, Boltzmann distributed negative ions and cold fluid positive ions. Considering the positive ion-neutral collisions and ignoring the effects of ionization and collisions between negative species and positive ions (neutrals), a modified Bohm sheath criterion and hence floating potential are derived by using multifluid model. Using the modified Bohm sheath criterion, the sheath characteristics such as spatial profiles of density, potential and net space charge density have been numerically investigated. It is found that increasing values of q-nonextensivity, electronegativity and collisionality lead to a decrease of the sheath thickness and an increase of the sheath potential and the net space charge density. With increasing values of the electron temperature to negative ion temperature ratio, the sheath thickness increases and the sheath potential as well as the net space charge density in the sheath region decreases.

  6. Coronal mass ejections and their sheath regions in interplanetary space

    Science.gov (United States)

    Kilpua, Emilia; Koskinen, Hannu E. J.; Pulkkinen, Tuija I.

    2017-11-01

    Interplanetary coronal mass ejections (ICMEs) are large-scale heliospheric transients that originate from the Sun. When an ICME is sufficiently faster than the preceding solar wind, a shock wave develops ahead of the ICME. The turbulent region between the shock and the ICME is called the sheath region. ICMEs and their sheaths and shocks are all interesting structures from the fundamental plasma physics viewpoint. They are also key drivers of space weather disturbances in the heliosphere and planetary environments. ICME-driven shock waves can accelerate charged particles to high energies. Sheaths and ICMEs drive practically all intense geospace storms at the Earth, and they can also affect dramatically the planetary radiation environments and atmospheres. This review focuses on the current understanding of observational signatures and properties of ICMEs and the associated sheath regions based on five decades of studies. In addition, we discuss modelling of ICMEs and many fundamental outstanding questions on their origin, evolution and effects, largely due to the limitations of single spacecraft observations of these macro-scale structures. We also present current understanding of space weather consequences of these large-scale solar wind structures, including effects at the other Solar System planets and exoplanets. We specially emphasize the different origin, properties and consequences of the sheaths and ICMEs.

  7. Ontogeny of the sheathing leaf base in maize (Zea mays).

    Science.gov (United States)

    Johnston, Robyn; Leiboff, Samuel; Scanlon, Michael J

    2015-01-01

    Leaves develop from the shoot apical meristem (SAM) via recruitment of leaf founder cells. Unlike eudicots, most monocot leaves display parallel venation and sheathing bases wherein the margins overlap the stem. Here we utilized computed tomography (CT) imaging, localization of PIN-FORMED1 (PIN1) auxin transport proteins, and in situ hybridization of leaf developmental transcripts to analyze the ontogeny of monocot leaf morphology in maize (Zea mays). CT imaging of whole-mounted shoot apices illustrates the plastochron-specific stages during initiation of the basal sheath margins from the tubular disc of insertion (DOI). PIN1 localizations identify basipetal auxin transport in the SAM L1 layer at the site of leaf initiation, a process that continues reiteratively during later recruitment of lateral leaf domains. Refinement of these auxin transport domains results in multiple, parallel provascular strands within the initiating primordium. By contrast, auxin is transported from the L2 toward the L1 at the developing margins of the leaf sheath. Transcripts involved in organ boundary formation and dorsiventral patterning accumulate within the DOI, preceding the outgrowth of the overlapping margins of the sheathing leaf base. We suggest a model wherein sheathing bases and parallel veins are both patterned via the extended recruitment of lateral maize leaf domains from the SAM. © 2014 The Authors. New Phytologist © 2014 New Phytologist Trust.

  8. Revisiting the plasma sheath—dust in plasma sheath

    Energy Technology Data Exchange (ETDEWEB)

    Das, G. C. [Mathematical Science Division, IASST, Guwahati 781014 (India); Deka, R.; Bora, M. P., E-mail: mpbora@gauhati.ac.in [Physics Department, Gauhati University, Guwahati 781014 (India)

    2016-04-15

    In this work, we have considered the formation of warm plasma sheath in the vicinity of a wall in a plasma with considerable presence of dust particles. As an example, we have used the parameters relevant in case of plasma sheath formed around surfaces of various solid bodies in space, though the results obtained in this work can be applied to any other physical situation such as laboratory plasma. In the ion-acoustic time scale, we neglect the dust dynamics. The dust particles affect the sheath dynamics by affecting the Poisson equation which determines the plasma potential in the sheath region. It is important to note that our calculations are valid only when the amount of dust particles is not sufficient so as to affect the plasma dynamics in the dust-acoustic time scale, but enough to affect the plasma sheath. We have assumed the current to a dust particle to be balanced throughout the analysis. This makes the grain potential dependent on plasma potential, which is then incorporated into the Poisson equation. The resultant numerical model becomes an initial value problem, which is described by a 1-D integro-differential equation, which is then solved self-consistently by incorporating the change in plasma potential caused by inclusion of the dust potential in the Poisson equation.

  9. Sheath-accumulating Propagation of Interplanetary Coronal Mass Ejection

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, Takuya; Shibata, Kazunari, E-mail: takahasi@kusastro.kyoto-u.ac.jp [Kwasan and Hida Observatories, Kyoto University, Yamashina, Kyoto 607–8471 (Japan)

    2017-03-10

    Fast interplanetary coronal mass ejections (ICMEs) are the drivers of strong space weather storms such as solar energetic particle events and geomagnetic storms. The connection between the space-weather-impacting solar wind disturbances associated with fast ICMEs at Earth and the characteristics of causative energetic CMEs observed near the Sun is a key question in the study of space weather storms, as well as in the development of practical space weather prediction. Such shock-driving fast ICMEs usually expand at supersonic speeds during the propagation, resulting in the continuous accumulation of shocked sheath plasma ahead. In this paper, we propose a “sheath-accumulating propagation” (SAP) model that describes the coevolution of the interplanetary sheath and decelerating ICME ejecta by taking into account the process of upstream solar wind plasma accumulation within the sheath region. Based on the SAP model, we discuss (1) ICME deceleration characteristics; (2) the fundamental condition for fast ICMEs at Earth; (3) the thickness of interplanetary sheaths; (4) arrival time prediction; and (5) the super-intense geomagnetic storms associated with huge solar flares. We quantitatively show that not only the speed but also the mass of the CME are crucial for discussing the above five points. The similarities and differences between the SAP model, the drag-based model, and the“snow-plow” model proposed by Tappin are also discussed.

  10. Dust crystal in the electrode sheath of a gaseous discharge

    International Nuclear Information System (INIS)

    Schweigert, I.V.; Schweigert, V.A.

    2002-01-01

    The phenomena observed in strongly coupled dusty plasmas in the electrode sheath of gas discharge clearly indicate that the screened Coulomb potential is not valid for inter-particle interaction. The reason why the conventional model breaks down is clear now. The strong electric field, accelerating ions toward the cathode, leads to an asymmetrical particle shielding and the appearance of an attractive component in the inter-particle force. The sheath plasma with micro-particles is non Hamiltonian system because of input of energy from ion flux from the bulk plasma. The models of interaction potential of microparticles in sheath are proposed. The first is the linear effective positive charge (EPC). On the basis of this model the stability of the dust crystal in the sheath is analyzed both analytically and in MD simulations. The scenario of crystal melting is described. The role of different types of defects in the local heating of the crystal is considered. The next non-linear model of sheath plasma with micro-particles allows to find all parameter of plasma crystal: particle charge, inter-particle distance and study the structural transition. We constructed the analytical expression for inter-particle potential and have found the mechanism acceleration of extra particle beneath the monolayer. Recently new more simple analytical kinetic approach, accounting for ion collisions, have been developed. The structural transition in the dust molecular was obtained in simulation with multipole expansion model interaction potential

  11. Coronal mass ejections and their sheath regions in interplanetary space

    Directory of Open Access Journals (Sweden)

    Emilia Kilpua

    2017-11-01

    Full Text Available Abstract Interplanetary coronal mass ejections (ICMEs are large-scale heliospheric transients that originate from the Sun. When an ICME is sufficiently faster than the preceding solar wind, a shock wave develops ahead of the ICME. The turbulent region between the shock and the ICME is called the sheath region. ICMEs and their sheaths and shocks are all interesting structures from the fundamental plasma physics viewpoint. They are also key drivers of space weather disturbances in the heliosphere and planetary environments. ICME-driven shock waves can accelerate charged particles to high energies. Sheaths and ICMEs drive practically all intense geospace storms at the Earth, and they can also affect dramatically the planetary radiation environments and atmospheres. This review focuses on the current understanding of observational signatures and properties of ICMEs and the associated sheath regions based on five decades of studies. In addition, we discuss modelling of ICMEs and many fundamental outstanding questions on their origin, evolution and effects, largely due to the limitations of single spacecraft observations of these macro-scale structures. We also present current understanding of space weather consequences of these large-scale solar wind structures, including effects at the other Solar System planets and exoplanets. We specially emphasize the different origin, properties and consequences of the sheaths and ICMEs.

  12. Sheath-accumulating Propagation of Interplanetary Coronal Mass Ejection

    International Nuclear Information System (INIS)

    Takahashi, Takuya; Shibata, Kazunari

    2017-01-01

    Fast interplanetary coronal mass ejections (ICMEs) are the drivers of strong space weather storms such as solar energetic particle events and geomagnetic storms. The connection between the space-weather-impacting solar wind disturbances associated with fast ICMEs at Earth and the characteristics of causative energetic CMEs observed near the Sun is a key question in the study of space weather storms, as well as in the development of practical space weather prediction. Such shock-driving fast ICMEs usually expand at supersonic speeds during the propagation, resulting in the continuous accumulation of shocked sheath plasma ahead. In this paper, we propose a “sheath-accumulating propagation” (SAP) model that describes the coevolution of the interplanetary sheath and decelerating ICME ejecta by taking into account the process of upstream solar wind plasma accumulation within the sheath region. Based on the SAP model, we discuss (1) ICME deceleration characteristics; (2) the fundamental condition for fast ICMEs at Earth; (3) the thickness of interplanetary sheaths; (4) arrival time prediction; and (5) the super-intense geomagnetic storms associated with huge solar flares. We quantitatively show that not only the speed but also the mass of the CME are crucial for discussing the above five points. The similarities and differences between the SAP model, the drag-based model, and the“snow-plow” model proposed by Tappin are also discussed.

  13. Structural Conservation of the Myoviridae Phage Tail Sheath Protein Fold

    Energy Technology Data Exchange (ETDEWEB)

    Aksyuk, Anastasia A.; Kurochkina, Lidia P.; Fokine, Andrei; Forouhar, Farhad; Mesyanzhinov, Vadim V.; Tong, Liang; Rossmann, Michael G. (SOIBC); (Purdue); (Columbia)

    2012-02-21

    Bacteriophage phiKZ is a giant phage that infects Pseudomonas aeruginosa, a human pathogen. The phiKZ virion consists of a 1450 {angstrom} diameter icosahedral head and a 2000 {angstrom}-long contractile tail. The structure of the whole virus was previously reported, showing that its tail organization in the extended state is similar to the well-studied Myovirus bacteriophage T4 tail. The crystal structure of a tail sheath protein fragment of phiKZ was determined to 2.4 {angstrom} resolution. Furthermore, crystal structures of two prophage tail sheath proteins were determined to 1.9 and 3.3 {angstrom} resolution. Despite low sequence identity between these proteins, all of these structures have a similar fold. The crystal structure of the phiKZ tail sheath protein has been fitted into cryo-electron-microscopy reconstructions of the extended tail sheath and of a polysheath. The structural rearrangement of the phiKZ tail sheath contraction was found to be similar to that of phage T4.

  14. Experimental investigation of plasma sheaths in magnetic mirror and cusp configurations

    Science.gov (United States)

    Jiang, Zhengqi; Wei, Zi-an; Ma, J. X.

    2017-11-01

    Sheath structures near a metal plate in a magnetized plasma were experimentally investigated in magnetic mirror and cusp configurations. Plasma parameters and the sheath potential distributions were probed by a planar and an emissive probe, respectively. The measured sheath profiles in the mirror configuration show that the sheath thickness first decreases and then increases when the magnetic strength is raised. A magnetic flux-tube model was used to explain this result. In the cusp configuration, the measured sheath thickness decreases with the increase of the coil current creating the magnetic cusp. However, when normalized by the electron Debye length, the dependence of the sheath thickness on the coil current is reversed.

  15. The Effect of Sodium Hyaluronate on Ligamentation and Biomechanical Property of Tendon in Repair of Achilles Tendon Defect with Polyethylene Terephthalate Artificial Ligament: A Rabbit Tendon Repair Model.

    Science.gov (United States)

    Li, Shengkun; Ma, Kui; Li, Hong; Jiang, Jia; Chen, Shiyi

    2016-01-01

    The Achilles tendon is the most common ruptured tendon of human body. Reconstruction with polyethylene terephthalate (PET) artificial ligament is recommended in some serious cases. Sodium hyaluronate (HA) is beneficial for the healing of tendon injuries. We aimed to determine the effect of sodium hyaluronate in repair of Achilles tendon defect with PET artificial ligament in an animal tendon repair model. Sixteen New Zealand White rabbits were divided into two groups. Eight rabbits repaired with PET were assigned to PET group; the other eight rabbits repaired with PET along with injection of HE were assigned to HA-PET group. All rabbits were sacrificed at 4 and 8 weeks postoperatively for biomechanical and histological examination. The HA-PET group revealed higher biomechanical property compared with the PET group. Histologically, more collagen tissues grew into the HA-PET group compared with PET group. In conclusion, application of sodium hyaluronate can improve the healing of Achilles tendon reconstruction with polyethylene terephthalate artificial ligament.

  16. Peroneal tendon displacement accompanying intra-articular calcaneal fractures.

    Science.gov (United States)

    Toussaint, Rull James; Lin, Darius; Ehrlichman, Lauren K; Ellington, J Kent; Strasser, Nicholas; Kwon, John Y

    2014-02-19

    Peroneal tendon displacement (subluxation or dislocation) accompanying an intra-articular calcaneal fracture is often undetected and under-treated. The goals of this study were to determine (1) the prevalence of peroneal tendon displacement accompanying intra-articular calcaneal fractures, (2) the association of tendon displacement with fracture classifications, (3) the association of tendon displacement with heel width, and (4) the rate of missed diagnosis of the tendon displacement on radiographs and computed tomography (CT) scans and the resulting treatment rate. A retrospective radiographic review of all calcaneal fractures presenting at three institutions from June 30, 2006, to June 30, 2011, was performed. CT imaging of 421 intra-articular calcaneal fractures involving the posterior facet was available for review. The prevalence of peroneal tendon displacement was noted and its associations with fracture classification and heel width were evaluated. Peroneal tendon displacement was identified in 118 (28.0%) of the 421 calcaneal fracture cases. The presence of tendon displacement was significantly associated with joint-depression fractures compared with tongue-type fractures (p displacement had been identified in the radiology reports. Although sixty-five (55.1%) of the fractures with tendon displacement had been treated with internal fixation, the tendon displacement was treated surgically in only seven (10.8%) of these cases. Analysis of CT images showed a 28% prevalence of peroneal tendon displacement accompanying intra-articular calcaneal fractures. Surgeons and radiologists are encouraged to consider this association.

  17. Plantar tendons of the foot: MR imaging and US.

    Science.gov (United States)

    Donovan, Andrea; Rosenberg, Zehava Sadka; Bencardino, Jenny T; Velez, Zoraida Restrepo; Blonder, David B; Ciavarra, Gina A; Adler, Ronald Steven

    2013-01-01

    Tendon disorders along the plantar aspect of the foot may lead to significant symptoms but are often clinically misdiagnosed. Familiarity with the normal anatomy of the plantar tendons and its appearance at magnetic resonance (MR) imaging and ultrasonography (US) is essential for recognizing plantar tendon disorders. At MR imaging, the course of the plantar tendons is optimally visualized with dedicated imaging of the midfoot and forefoot. This imaging should include short-axis images obtained perpendicular to the long axis of the metatarsal shafts, which allows true cross-sectional evaluation of the plantar tendons. Normal plantar tendons appear as low-signal-intensity structures with all MR sequences. At US, accurate evaluation of the tendons requires that the ultrasound beam be perpendicular to the tendon. The normal tendon appears as a compact linear band of echogenic tissue that contains a fine, mixed hypoechoic and hyperechoic internal fibrillar pattern. Tendon injuries can be grouped into six major categories: tendinosis, peritendinosis, tenosynovitis, entrapment, rupture, and instability (subluxation or dislocation) and can be well assessed with both MR imaging and US. The radiologist plays an important role in the diagnosis of plantar tendon disorders, and recognizing their imaging appearances at MR imaging and US is essential.

  18. Biceps-Related Physical Findings Are Useful to Prevent Misdiagnosis of Cervical Spondylotic Amyotrophy as a Rotator Cuff Tear.

    Science.gov (United States)

    Iwata, Eiichiro; Shigematsu, Hideki; Inoue, Kazuya; Egawa, Takuya; Tanaka, Masato; Okuda, Akinori; Morimoto, Yasuhiko; Masuda, Keisuke; Yamamoto, Yusuke; Sakamoto, Yoshihiro; Koizumi, Munehisa; Tanaka, Yasuhito

    2018-02-01

    Case-control study. The aim of the present study was to identify physical findings useful for differentiating between cervical spondylotic amyotrophy (CSA) and rotator cuff tears to prevent the misdiagnosis of CSA as a rotator cuff tear. CSA and rotator cuff tears are often confused among patients presenting with difficulty in shoulder elevation. Twenty-five patients with CSA and 27 with rotator cuff tears were enrolled. We included five physical findings specific to CSA that were observed in both CSA and rotator cuff tear patients. The findings were as follows: (1) weakness of the deltoid muscle, (2) weakness of the biceps muscle, (3) atrophy of the deltoid muscle, (4) atrophy of the biceps muscle, and (5) swallow-tail sign (assessment of the posterior fibers of the deltoid). Among 25 CSA patients, 10 (40.0%) were misdiagnosed with a rotator cuff tear on initial diagnosis. The sensitivity and specificity of each physical finding were as follows: (1) deltoid weakness (sensitivity, 92.0%; specificity, 55.6%), (2) biceps weakness (sensitivity, 80.0%; specificity, 100%), (3) deltoid atrophy (sensitivity, 96.0%; specificity, 77.8%), (4) biceps atrophy (sensitivity, 88.8%; specificity, 92.6%), and (5) swallow-tail sign (sensitivity, 56.0%; specificity, 74.1%). There were statistically significant differences in each physical finding. CSA is likely to be misdiagnosed as a rotator cuff tear; however, weakness and atrophy of the biceps are useful findings for differentiating between CSA and rotator cuff tears to prevent misdiagnosis.

  19. Variation in the insertion of the palmaris longus tendon

    Science.gov (United States)

    Sunil, Vinutha; Rajanna, Shubha; Gitanjali; Kadaba, Jayanthi

    2015-01-01

    The palmaris longus is harvested as a tendon graft in various surgical procedures. We herein report the variations in the insertion of the palmaris longus tendon. During a routine dissection, a rare variation in the insertion of the palmaris longus tendon was observed. In the left forearm, the palmaris longus tendon bifurcated, while in the right forearm, the palmaris longus tendon trifurcated, giving rise to an accessory muscle, which passed superficial to the ulnar artery and ulnar nerve. The accessory muscle was supplied by a deep branch of the ulnar nerve, and the ulnar artery was observed to be tortuous. During reconstructive surgeries, surgeons should bear in mind the accessory muscle. Also, since the palmaris longus muscle provides a very useful graft in tendon surgery, every surgeon should be aware of the variations in the insertion of the palmaris longus tendon. PMID:25640108

  20. A Rare Case of Simultaneous Acute Bilateral Quadriceps Tendon Rupture and Unilateral Achilles Tendon Rupture

    Directory of Open Access Journals (Sweden)

    Wei Yee Leong

    2013-07-01

    Full Text Available Introduction: There have been multiple reported cases of bilateral quadriceps tendon ruptures (QTR in the literature. These injuries frequently associated with delayed diagnosis, which results in delayed surgical treatment. In very unusual cases, bilateral QTRs can be associated with other simultaneous tendon ruptures. Case Report: We present a rare case of bilateral QTR with a simultaneous Achilles Tendon Rupture involving a 31 years old Caucasian man who is a semi-professional body builder taking anabolic steroids. To date bilateral QTR with additional TA rupture has only been reported once in the literature and to our knowledge this is the first reported case of bilateral QTR and simultaneous TA rupture in a young, fit and healthy individual. Conclusion: The diagnosis of bilateral QTR alone can sometimes be challenging and the possibility of even further tendon injuries should be carefully assessed. A delay in diagnosis could result in delay in treatment and potentially worse outcome for the patient. Keywords: Quadriceps tendon rupture; Achilles tendon rupture; Bilateral.

  1. A posterior tibial tendon skipping rope

    NARCIS (Netherlands)

    van Sterkenburg, M. N.; Haverkamp, D.; van Dijk, C. N.; Kerkhoffs, G. M. M. J.

    2010-01-01

    This report presents an athletic patient with swelling and progressive pain on the posteromedial side of his right ankle on weight bearing. MRI demonstrated tenosynovitis and suspicion of a length rupture. On posterior tibial tendoscopy, there was no rupture, but medial from the tendon a tissue cord

  2. Radiographic Features of Acute Patellar Tendon Rupture.

    Science.gov (United States)

    Fazal, Muhammad Ali; Moonot, Pradeep; Haddad, Fares

    2015-11-01

    The purpose of our study was to assess soft tissue features of acute patellar tendon rupture on lateral knee radiograph that would facilitate early diagnosis. The participants were divided into two groups of 35 patients each. There were 28 men and seven women with a mean age of 46 years in the control group and 26 men and nine women with a mean age of 47 years in the rupture group. The lateral knee radiograph of each patient was evaluated for Insall-Salvati ratio for patella alta, increased density of the infrapatellar fat pad, appearance of the soft tissue margin of the patellar tendon and bony avulsions. In the rupture group there were three consistent soft tissue radiographic features in addition to patellar alta. These were increased density of infrapatellar fat pad; loss of sharp, well-defined linear margins of the patellar tendon and angulated wavy margin of the patellar tendon while in the control group these features were not observed. The soft tissue radiographic features described in the rupture group are consistent and reliable. When coupled with careful clinical assessment, these will aid in early diagnosis and further imaging will be seldom required. © 2015 Chinese Orthopaedic Association and Wiley Publishing Asia Pty Ltd.

  3. Engaging Stem Cells for Customized Tendon Regeneration

    Directory of Open Access Journals (Sweden)

    Hatim Thaker

    2012-01-01

    Full Text Available The need for a consistent therapeutic approach to tendon injury repair is long overdue. Patients with tendon microtears or full ruptures are eligible for a wide range of invasive and non invasive interventions, often subjectively decided by the physician. Surgery produces the best outcomes, and while studies have been conducted to optimize graft constructs and to track outcomes, the data from these studies have been inconclusive on the whole. What has been established is a clear understanding of healthy tendon architecture and the inherent process of healing. With this knowledge, tissue regeneration efforts have achieved immense progress in scaffold design, cell line selection, and, more recently, the appropriate use of cytokines and growth factors. This paper evaluates the plasticity of bone-marrow-derived stem cells and the elasticity of recently developed biomaterials towards tendon regeneration efforts. Mesenchymal stem cells (MSCs, hematopoietic progenitor cells, and poly(1,8-octanediol co-citrate scaffolds (POC are discussed in the context of established grafting strategies. With POC scaffolds to cradle the growth of MSCs and hematopoietic progenitor cells, developing a fibroelastic network guided by cytokines and growth factors may contribute towards consistent graft constructs, enhanced functionality, and better patient outcomes.

  4. [The history of flexor tendon surgery].

    Science.gov (United States)

    Chamay, A

    1997-01-01

    Flexor tendon injuries were already treated in antiquity by Hippocrates, Galien and Avicenne. Since the Renaissance, other surgeons have attempted to repair flexor tendon injuries, but without success due to problems related to unsuitable materials and ignorance of the basic rules of asepsis and the absence of antiseptics until the second half of the 19th century. The first successful flexor tendon grafts in man were performed by K. Biesalski in 1910, E. Lexer in 1912 and L. Mayer in 1916. These three authors published their series of grafts and described in detail the anatomical, physiological and technical principles to be respected. St. Bunnell, in 1918, developed various pull-out direct suture procedures, but faced with the problems of adhesions, he abandoned this technique and proposed not to repair flexors in the digital tunnels but to graft them. He defined the famous zone which he called No man's land, which subsequently became Claude Verdan's zone II, in 1959. In 1960, C. Verdan published his first series of sutures maintained by 2 pins in zone II with comparable results to those obtained after grafting. In 1967, H. Kleinert, with his mobile suture, became the leader of direct tendon repair in zone II. 2-stage grafts were introduced in 1965 under the impetus of J. Hunter, who revised and popularized the studies conducted by A. Bassett and R.E. Caroll in 1950.

  5. Effect of electron emission on an ion sheath structure

    International Nuclear Information System (INIS)

    Mishra, M K; Phukan, A; Chakraborty, M

    2014-01-01

    This article reports on the variations of ion sheath structures due to the emission of both hot and cold electrons in the target plasma region of a double plasma device. The ion sheath is produced in front of a negatively biased plate. The plasma is produced by hot filament discharge in the source region, and no discharge is created in the target region of the device. The plate is placed in the target (diffused plasma) region where cold electron emitting filaments are present. These cold electrons are free from maintenance of discharge, which is sustained in the source region. The hot ionizing electrons are present in the source region. Three important parameters are changed by both hot and cold electrons i.e. plasma density, plasma potential and electron temperature. The decrease in plasma potential and the increase in plasma density lead to the contraction of the sheath. (paper)

  6. Anomalous Capacitive Sheath with Deep Radio Frequency Electric Field Penetration

    International Nuclear Information System (INIS)

    Kaganovich, Igor D.

    2002-01-01

    A novel nonlinear effect of anomalously deep penetration of an external radio-frequency electric field into a plasma is described. A self-consistent kinetic treatment reveals a transition region between the sheath and the plasma. Because of the electron velocity modulation in the sheath, bunches in the energetic electron density are formed in the transition region adjusted to the sheath. The width of the region is of order V(subscript T)/omega, where V(subscript T) is the electron thermal velocity, and w is frequency of the electric field. The presence of the electric field in the transition region results in a cooling of the energetic electrons and an additional heating of the cold electrons in comparison with the case when the transition region is neglected

  7. Plasma sheath axial phase dynamics in coaxial device

    Energy Technology Data Exchange (ETDEWEB)

    Soliman, H.M. (Plasma Physics Dept., NRC, Atomic Energy Authority, Cairo (Egypt)); Masoud, M.M. (Plasma Physics Dept., NRC, Atomic Energy Authority, Cairo (Egypt))

    1994-10-01

    The study of the plasma sheath dynamics in the axial phase has been carried out in a 3 kJ coaxial system of Mather type for two different inner electrode (IE) lengths, 20 cm and 31.5 cm. For both lengths, measurements showed that the plasma sheath is splitted into two layers at the breech, which is referred to as a shock front and its magnetic piston. It has been found that the two layers of the plasma current sheath rotate around the inner electrode. At the muzzle the back layer reverse its rotation direction due to the magnetic field structure of the system. Results showed that the axial velocity of the first layer is greater than the second one all over the axial phase within the range between 1.4 and 1.7. (orig.).

  8. Plasma sheath axial phase dynamics in coaxial device

    International Nuclear Information System (INIS)

    Soliman, H.M.; Masoud, M.M.

    1994-01-01

    The study of the plasma sheath dynamics in the axial phase has been carried out in a 3 kJ coaxial system of Mather type for two different inner electrode (IE) lengths, 20 cm and 31.5 cm. For both lengths, measurements showed that the plasma sheath is splitted into two layers at the breech, which is referred to as a shock front and its magnetic piston. It has been found that the two layers of the plasma current sheath rotate around the inner electrode. At the muzzle the back layer reverse its rotation direction due to the magnetic field structure of the system. Results showed that the axial velocity of the first layer is greater than the second one all over the axial phase within the range between 1.4 and 1.7. (orig.)

  9. Spontaneous rectus sheath hematoma: The utility of CT angiography

    Directory of Open Access Journals (Sweden)

    Antonio Pierro, MD

    2018-04-01

    Full Text Available We described the utility of computed tomography (CT angiography in detection of bleeding vessels for a rapid percutaneous arterial embolization of the spontaneous rectus sheath hematoma. A 70-year-old woman comes to our attention with acute abdominal pain and a low hemoglobin level. An unenhanced CT was performed demonstrating a large rectus sheath hematoma. A conservative management was initially established. Despite this therapy, the abdominal pain increased together with a further decrease of hemoglobin values. A CT angiography was then performed, demonstrating an active bleeding within the hematoma and addressing the patient to a rapid percutaneous arterial embolization. Keywords: Rectus sheath hematoma, Acute abdomen, Arterial embolization, CT angiography, Active bleeding

  10. Scalar perturbation in warm tachyon inflation in LQC in light of Plank and BICEP2

    Energy Technology Data Exchange (ETDEWEB)

    Setare, M.R., E-mail: rezakord@ipm.ir [Department of Science, Campus of Bijar, University of Kurdistan, Bijar (Iran, Islamic Republic of); Kamali, V., E-mail: vkamali1362@gmail.com [Department of Physics, Faculty of Science, Bu-Ali Sina University, Hamedan, 65178 (Iran, Islamic Republic of)

    2014-12-12

    We study warm-tachyon inflationary universe model in the context of the effective field theory of loop quantum cosmology. In slow-roll approximation the primordial perturbation spectrums for this model are calculated. We also obtain the general expressions of the tensor-to-scalar ratio and scalar spectral index. We develop this model by using exponential potential, the characteristics of this model are presented in great details. The parameters of the model are restricted by recent observational data from Planck, WMAP9 and BICEP2.

  11. Higgs inflation is still alive after the results from BICEP2.

    Science.gov (United States)

    Hamada, Yuta; Kawai, Hikaru; Oda, Kin-Ya; Park, Seong Chan

    2014-06-20

    The observed value of the Higgs boson mass indicates that the Higgs potential becomes small and flat at the scale around 10(17)  GeV. Having this fact in mind, we reconsider the Higgs inflation scenario proposed by Bezrukov and Shaposhnikov. It turns out that the nonminimal coupling ξ of the Higgs squared to the Ricci scalar can be smaller than 10. For example, ξ=7 corresponds to the tensor-to-scalar ratio r≃0.2, which is consistent with the recent observation by BICEP2.

  12. Myosin heavy chain composition of single fibres from m. biceps brachii of male body builders

    DEFF Research Database (Denmark)

    Klitgaard, H; Zhou, M.-Y.; Richter, Erik

    1990-01-01

    The myosin heavy chain (MHC) composition of single fibres from m. biceps brachii of young sedentary men (28 +/- 0.4 years, mean +/- SE, n = 4) and male body builders (25 +/- 2.0 years, n = 4) was analysed with a sensitive one-dimensional electrophoretic technique. Compared with sedentary men...... expression of MHC isoforms within histochemical type II fibres of human skeletal muscle with body building. Furthermore, in human skeletal muscle differences in expression of MHC isoforms may not always be reflected in the traditional histochemical classification of types I, IIa, IIb and IIc fibres....

  13. Mineral distributions at the developing tendon enthesis.

    Science.gov (United States)

    Schwartz, Andrea G; Pasteris, Jill D; Genin, Guy M; Daulton, Tyrone L; Thomopoulos, Stavros

    2012-01-01

    Tendon attaches to bone across a functionally graded interface, "the enthesis". A gradient of mineral content is believed to play an important role for dissipation of stress concentrations at mature fibrocartilaginous interfaces. Surgical repair of injured tendon to bone often fails, suggesting that the enthesis does not regenerate in a healing setting. Understanding the development and the micro/nano-meter structure of this unique interface may provide novel insights for the improvement of repair strategies. This study monitored the development of transitional tissue at the murine supraspinatus tendon enthesis, which begins postnatally and is completed by postnatal day 28. The micrometer-scale distribution of mineral across the developing enthesis was studied by X-ray micro-computed tomography and Raman microprobe spectroscopy. Analyzed regions were identified and further studied by histomorphometry. The nanometer-scale distribution of mineral and collagen fibrils at the developing interface was studied using transmission electron microscopy (TEM). A zone (∼20 µm) exhibiting a gradient in mineral relative to collagen was detected at the leading edge of the hard-soft tissue interface as early as postnatal day 7. Nanocharacterization by TEM suggested that this mineral gradient arose from intrinsic surface roughness on the scale of tens of nanometers at the mineralized front. Microcomputed tomography measurements indicated increases in bone mineral density with time. Raman spectroscopy measurements revealed that the mineral-to-collagen ratio on the mineralized side of the interface was constant throughout postnatal development. An increase in the carbonate concentration of the apatite mineral phase over time suggested possible matrix remodeling during postnatal development. Comparison of Raman-based observations of localized mineral content with histomorphological features indicated that development of the graded mineralized interface is linked to endochondral

  14. Photovoltaic building sheathing element with anti-slide features

    Science.gov (United States)

    Keenihan, James R.; Langmaid, Joseph A.; Lopez, Leonardo C.

    2015-09-08

    The present invention is premised` upon an assembly that includes at least a photovoltaic building sheathing element capable of being affixed on a building structure, the photovoltaic building sheathing element. The element including a photovoltaic cell assembly, a body portion attached to one or more portions of the photovoltaic cell assembly; and at feast a first and a second connector assembly capable of directly or indirectly electrically connecting the photovoltaic cell assembly to one or more adjoining devices; wherein the body portion includes one or more geometric features adapted to engage a vertically adjoining device before installation.

  15. Dengue fever with rectus sheath hematoma: A case report

    Directory of Open Access Journals (Sweden)

    Anurag Sharma

    2014-01-01

    Full Text Available Dengue fever, also known as breakbone fever, is an infectious tropical disease caused by the Dengue virus. It is associated with a number of complications, which are well documented. However, Dengue fever associated with rectus sheath hematoma (RSH is a very rare complication. Only one case report has been published prior supporting the association of Dengue fever with RSH. We report a case of Dengue fever who presented with RSH and was successfully treated conservatively. RSH is also an uncommon cause of acute abdominal pain. It is accumulation of blood in the sheath of the rectus abdominis, secondary to rupture of an epigastric vessel or muscle tear.

  16. Use of a hot sheath Tormac for advance fuels

    International Nuclear Information System (INIS)

    Levine, M.A.

    1977-01-01

    The use of hot electrons in a Tormac sheath is predicted to improve stability and increase ntau by an order of magnitude. An effective ntau for energy containment is derived and system parameters for several advance fuels are shown. In none of the advance fuels cases considered is a reactor with fields greater than 10 Wb or major plasma radius of more than 3 m required for ignition. Minimum systems have power output of under 100 MW thermal. System parameters for a hot sheath Tormac have a wide latitude. Sizes, magnetic fields, operating temperatures can be chosen to optimize engineering and economic considerations

  17. Changes in Achilles tendon mechanical properties following eccentric heel drop exercise are specific to the free tendon.

    Science.gov (United States)

    Obst, S J; Newsham-West, R; Barrett, R S

    2016-04-01

    Mechanical loading of the Achilles tendon during isolated eccentric contractions could induce immediate and region-dependent changes in mechanical properties. Three-dimensional ultrasound was used to examine the immediate effect of isolated eccentric exercise on the mechanical properties of the distal (free tendon) and proximal (gastrocnemii) regions of the Achilles tendon. Participants (n = 14) underwent two testing sessions in which tendon measurements were made at rest and during a 30% and 70% isometric plantar flexion contractions immediately before and after either: (a) 3 × 15 eccentric heel drops or (b) 10-min rest. There was a significant time-by-session interaction for free tendon length and strain for all loading conditions (P tendon length and strain at all contraction intensities after eccentric exercise (P tendon for any of the measured parameters. Immediate changes in Achilles tendon mechanical properties were specific to the free tendon and consistent with changes due to mechanical creep. These findings suggest that the mechanical properties of the free tendon may be more vulnerable to change with exercise compared with the gastrocnemii aponeurosis or tendon. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  18. [Reconstruction of the extensor pollicis longus tendon by transposition of the extensor indicis tendon].

    Science.gov (United States)

    Loos, A; Kalb, K; Van Schoonhoven, J; Landsleitner Dagger, B

    2003-12-01

    Rupture of the extensor pollicis longus-tendon (EPL) is a frequent complication after distal radius fractures. Other traumatic and non-traumatic reasons for this tendon lesion are known, including a theory about a disorder in the blood supply to the tendon itself. We examined 40 patients after reconstruction of the EPL-tendon in a mean follow-up time of 30 months. All patients were clinically examined and a DASH questionnaire was answered by all patients. The method to reconstruct the EPL-tendon was the transposition of the extensor indicis-tendon. After the operations the thumb was put in a splint for four weeks in a "hitch-hiker's-position". 31 ruptures of the tendon (77.5 %) were a result of trauma. In 20 of them (50 %) a distal radius fracture had occurred. Clinical examination included measurements of the movement of the thumb- and index-finger joints, the grip strength and the maximal span of the hand. Significant differences were not found. The isolated extension of the index finger was possible in all patients. But it was reduced in ten cases which represent 25 %. Our results were evaluated by the Geldmacher score to evaluate the reconstruction of the EPL-tendon. 20 % excellent, 65 % good, 12.5 % fair and 2.5 % poor results were reached. The Geldmacher score was used critically. We suggest its modification for the evaluation of thumb abduction. The DASH score reached a functional value of ten points which represents a very good result. In conclusion the extensor indicis-transposition is a safe method to reconstruct the EPL-tendon. Its substantial advantage is taking a healthy muscle as the motor, thereby avoiding the risk of using a degenerated muscle in late tendon reconstruction. A powerful extension of the index finger will be maintained by physical education. Generally, the loss of the extension of the index finger is negligible. It does not disturb the patients. But it has to be discussed with the patient before the operation.

  19. A suitable boundary condition for bounded plasma simulation without sheath resolution

    International Nuclear Information System (INIS)

    Parker, S.E.; Procassini, R.J.; Birdsall, C.K.; Cohen, B.I.

    1993-01-01

    We have developed a technique that allows for a sheath boundary layer without having to resolve the inherently small space and time scales of the sheath region. We refer to this technique as the logical sheath boundary condition. This boundary condition, when incorporated into a direct-implicit particle code, permits large space- and time-scale simulations of bounded systems, which would otherwise be impractical on current supercomputers. The lack of resolution of the collector sheath potential drop obtained from conventional implicit simulations at moderate values of ω pe Δt and Δz/λ De provides the motivation for the development of the logical sheath boundary condition. The algorithm for use of the logical sheath boundary condition in a particle simulation is presented. Results from simulations which use the logical sheath boundary condition are shown to compare reasonably well with those from an analytic theory and simulations in which the sheath is resolved

  20. Use of Ultrasound to Monitor Biceps Femoris Mechanical Adaptations after Injury in a Professional Soccer Player

    Directory of Open Access Journals (Sweden)

    Eleftherios Kellis, Nikiforos Galanis, Chrysanthos Chrysanthou, Nikolaos Kofotolis

    2016-03-01

    Full Text Available This study examined the use of ultrasound to monitor changes in the long head of the biceps femoris (BF architecture of aprofessional soccer player with acute first-time hamstring strain. The player followed a 14 session physiotherapy treatment until return to sport. The pennation angle and aponeurosis strain of the long head of the biceps femoris (BF were monitored at 6 occasions (up until 1 year after injury. The size of the scar / hematoma was reduced by 63.56% (length and 67.9% (width after the intervention and it was almost non-traceable one year after injury. The pennation angle of the fascicles underneath the scar showed a decline of 51.4% at the end of the intervention while an increase of 109.2% of the fascicles which were closer to deep aponeurosis was observed. In contrast, pennation angle of fascicles located away from the injury site were relatively unaffected. The treatment intervention resulted in a 57.9% to 77.3% decline of maximum strain per unit of MVC moment and remained similar one year after the intervention. This study provided an example of the potential use of ultrasound-based parameters to link the mechanical adaptations of the injured muscle to specific therapeutic intervention.

  1. Self-unitarization of New Higgs Inflation and compatibility with Planck and BICEP2 data

    International Nuclear Information System (INIS)

    Germani, Cristiano; Wintergerst, Nico; Watanabe, Yuki

    2014-01-01

    In this paper we show that the Germani-Kehagias model of Higgs inflation (or New Higgs Inflation), where the Higgs boson is kinetically non-minimally coupled to the Einstein tensor is in perfect compatibility with the latest Planck and BICEP2 data. Moreover, we show that the tension between the Planck and BICEP2 data can be relieved within the New Higgs inflation scenario by a negative running of the spectral index. Regarding the unitarity of the model, we argue that it is unitary throughout the evolution of the Universe. Weak couplings in the Higgs-Higgs and Higgs-graviton sectors are provided by a large background dependent cut-off scale during inflation. In the same regime, the W and Z gauge bosons acquire a very large mass, thus decouple. On the other hand, if they are also non-minimally coupled to the Higgs boson, their effective masses can be enormously reduced. In this case, the W and Z bosons are no longer decoupled. After inflation, the New Higgs model is well approximated by a quartic Galileon with a renormalizable potential. We argue that this can unitarily create the right conditions for inflation to eventually start

  2. Self-unitarization of New Higgs Inflation and compatibility with Planck and BICEP2 data

    Energy Technology Data Exchange (ETDEWEB)

    Germani, Cristiano; Wintergerst, Nico [Arnold Sommerfeld Center, Ludwig-Maximilians-Universität, Theresienstr. 37, 80333 München (Germany); Watanabe, Yuki, E-mail: cristiano.germani@lmu.de, E-mail: watanabe@resceu.s.u-tokyo.ac.jp, E-mail: nico.wintergerst@physik.lmu.de [Research Center for the Early Universe, University of Tokyo, Tokyo 113-0033 (Japan)

    2014-12-01

    In this paper we show that the Germani-Kehagias model of Higgs inflation (or New Higgs Inflation), where the Higgs boson is kinetically non-minimally coupled to the Einstein tensor is in perfect compatibility with the latest Planck and BICEP2 data. Moreover, we show that the tension between the Planck and BICEP2 data can be relieved within the New Higgs inflation scenario by a negative running of the spectral index. Regarding the unitarity of the model, we argue that it is unitary throughout the evolution of the Universe. Weak couplings in the Higgs-Higgs and Higgs-graviton sectors are provided by a large background dependent cut-off scale during inflation. In the same regime, the W and Z gauge bosons acquire a very large mass, thus decouple. On the other hand, if they are also non-minimally coupled to the Higgs boson, their effective masses can be enormously reduced. In this case, the W and Z bosons are no longer decoupled. After inflation, the New Higgs model is well approximated by a quartic Galileon with a renormalizable potential. We argue that this can unitarily create the right conditions for inflation to eventually start.

  3. SUSY see-saw and NMSO(10)GUT inflation after BICEP2

    International Nuclear Information System (INIS)

    Garg, Ila

    2016-01-01

    Supersymmetric see-saw slow roll inflection point inflation occurs along a MSSM D-flat direction associated with gauge invariant combination of Higgs, s lepton and right-handed s neutrino at a scale set by the right-handed neutrino mass M vc ∼ 10 6 -10 13 GeV. The tensor to scalar perturbation ratio r ∼ 10 -3 can be achieved in this scenario. However, this scenario faced difficulty in being embedded in the realistic new minimal supersymmetric SO(10) grand unified theory (NMSO(10)GUT). The recent discovery of B-mode polarization by BICEP2, changes the prospects of NMSO(10) GUT inflation. Inflection point models become strongly disfavoured, as the trilinear coupling of SUSY see-saw inflation potential gets suppressed relative to the mass parameter favoured by BICEP2. Large values of r ≈ 0.2 can be achieved with super-Planck scale inflaton values and mass scales of inflaton ≥10 13 GeV. In NMSO(10)GUT, this can be made possible with an admixture of heavy Higgs doublet fields, i.e., other than MSSM Higgs field, which are present and have masses of order GUT scale. (author)

  4. Fabrication and use of zircaloy/tantalum-sheathed cladding thermocouples and molybdenum/rhenium-sheathed fuel centerline thermocouples

    International Nuclear Information System (INIS)

    Wilkins, S.C.; Sepold, L.K.

    1985-01-01

    The thermocouples described in this report are zircaloy/tantalum-sheathed and molybdenum/rhenium alloy-sheathed instruments intended for fuel rod cladding and fuel centerline temperature measurements, respectively. Both types incorporate beryllium oxide insulation and tungsten/rhenium alloy thermoelements. These thermocouples, operated at temperatures of 2000 0 C and above, were developed for use in the internationally sponsored Severe Fuel Damage test series in the Power Burst Facility. The fabrication steps for both thermocouple types are described in detail. A laser-welding attachment technique for the cladding-type thermocouple is presented, and experience with alternate materials for cladding and fuel therocouples is discussed

  5. The relationship between shear force, compression, collagen characteristics, desmin degradation and sarcomere length in lamb biceps femoris.

    Science.gov (United States)

    Starkey, Colin P; Geesink, Geert H; van de Ven, Remy; Hopkins, David L

    2017-04-01

    This study aimed to identity the relationships between known variants of tenderness (collagen content (total and soluble), desmin degradation and sarcomere length) and shear force and compression in the biceps femoris aged for 14days from 112 mixed sex lambs. Desmin degradation was related to compression (Pcompression decreased. Sarcomere length (SL) was related to shear force (Pcompression (Pcompression, sarcomere length and soluble collagen. The findings from this experiment indicate that the known variants (soluble collagen, sarcomere length and desmin degradation) are related to shear force and compression in ovine biceps femoris. Crown Copyright © 2016. Published by Elsevier Ltd. All rights reserved.

  6. Effect of radiofrequency on capacitance of low density plasma sheath

    International Nuclear Information System (INIS)

    Carneiro, L.T.; Cunha Rapozo, C. da

    1988-01-01

    It is shown that the influence of induced radiofrequency potential (V RF ) modifies the Bohm theory on ion saturation current, measured with Langmuir probes. The effect of radiofrequency potential on diode type plasma sheath resonance is also investigated. (M.C.K.)

  7. Malignant peripheral nerve sheath tumor of the oculomotor nerve

    DEFF Research Database (Denmark)

    Kozic, D; Nagulic, M; Ostojic, J

    2006-01-01

    We present the short-term follow-up magnetic resonance (MR) studies and 1H-MR spectroscopy in a child with malignant peripheral nerve sheath tumor of the oculomotor nerve associated with other less aggressive cranial nerve schwannomas. The tumor revealed perineural extension and diffuse nerve...

  8. Double polymer sheathed carbon nanotube supercapacitors show enhanced cycling stability

    Science.gov (United States)

    Zhao, Wenqi; Wang, Shanshan; Wang, Chunhui; Wu, Shiting; Xu, Wenjing; Zou, Mingchu; Ouyang, An; Cao, Anyuan; Li, Yibin

    2015-12-01

    Pseudo-materials are effective in boosting the specific capacitance of supercapacitors, but during service their degradation may also be very strong, causing reduced cycling stability. Here, we show that a carbon nanotube sponge grafted by two conventional pseudo-polymer layers in sequence can serve as a porous supercapacitor electrode with significantly enhanced cycling stability compared with single polymer grafting. Creating conformal polymer coatings on the nanotube surface and the resulting double-sheath configuration are important structural factors leading to the enhanced performance. Combining different polymers as double sheaths as reported here might be a potential route to circumvent the dilemma of pseudo-materials, and to simultaneously improve the capacitance and stability for various energy storage devices.Pseudo-materials are effective in boosting the specific capacitance of supercapacitors, but during service their degradation may also be very strong, causing reduced cycling stability. Here, we show that a carbon nanotube sponge grafted by two conventional pseudo-polymer layers in sequence can serve as a porous supercapacitor electrode with significantly enhanced cycling stability compared with single polymer grafting. Creating conformal polymer coatings on the nanotube surface and the resulting double-sheath configuration are important structural factors leading to the enhanced performance. Combining different polymers as double sheaths as reported here might be a potential route to circumvent the dilemma of pseudo-materials, and to simultaneously improve the capacitance and stability for various energy storage devices. Electronic supplementary information (ESI) available. See DOI: 10.1039/c5nr05978j

  9. Extraction of antioxidant pigments from dye sorghum leaf sheaths

    NARCIS (Netherlands)

    Kayode, A.P.P.; Bara, C.A.; Dalode-Vieira, G.; Linnemann, A.R.; Nout, M.J.R.

    2012-01-01

    Extraction of antioxidant biocolorant pigments from leaf sheaths of dye sorghum was optimized. Effects of temperature and ethanol concentration of the extraction solvent on the concentrations of the 3-deoxyanthocyanidins, total phenolics and total anthocyanins, and the colour parameters of the

  10. Ion clusters, REB, and current sheath characteristics in focused discharges

    International Nuclear Information System (INIS)

    Bortolotti, A.; Brzosko, J.; DeChiara, P.; Kilic, H.; Mezzetti, F.; Nardi, V.; Powell, C.; Zeng, D.

    1990-01-01

    Small fluctuations in the current sheath characteristics (peak current density, FWHM of leading sheath, control parameters of sheath internal structure) are linked to wide fluctuations of ion and ion cluster emission from the pinch. Magnetic probe data are used for correlating variations of current sheath parameters with particle emission intensity, Z/M composition, particle energy spectrum. The emission of ion and ion clusters at 90 degrees from the axis of a plasma focus discharge is monitored simultaneously with the 0 degrees emission. The particle energy spectrum is analyzed with a Thomson (parabola) spectrometer (time resolution ∼ 1 nanosec). The cross-sectional structure of the REB at 180 degrees along the discharge axis is monitored via the deposition of collective-field accelerated ions on a target in the REB direction. Etched tracks of ion and ion clusters are in all cases recorded on CR-39 plates. Sharp peaks of the D + -ion spectrum at 90 degrees are found for E > 200 keV/unit charge in all focused discharges. These peaks are due to ion crossing of the azimuthal magnetic field of the pinch region, in a predominant ion cluster structure

  11. Electron sheath collapse in an applied-B ion diode

    International Nuclear Information System (INIS)

    Grechikha, A.V.

    1996-01-01

    The effect of the electron sheath collapse in an applied-B ion diode due to the presence of the resistive anode plasma layer was found. This effect is more damaging at higher diode voltages and may be responsible for the parasitic load effect observed in the experiments. (author). 4 figs., 2 refs

  12. Synovial sarcoma mimicking benign peripheral nerve sheath tumor

    Energy Technology Data Exchange (ETDEWEB)

    Larque, Ana B.; Nielsen, G.P.; Chebib, Ivan [Massachusetts General Hospital and Harvard Medical School, Department of Pathology, Boston, MA (United States); Bredella, Miriam A. [Massachusetts General Hospital and Harvard Medical School, Department of Radiology, Boston, MA (United States)

    2017-11-15

    To assess the radiographic and clinicopathologic features of synovial sarcoma of the nerve that were clinically or radiologically interpreted as benign peripheral nerve sheath tumor. Five patients with synovial sarcoma arising from the peripheral nerve and interpreted clinically and radiologically as peripheral nerve sheath tumors were identified. Clinicopathologic and imaging features were evaluated. There were three females and two males, ranging in age from 28 to 50 (mean 35.8) years. Most patients (4/5) complained of a mass, discomfort or pain. MR images demonstrated a heterogeneous, enhancing, soft tissue mass contiguous with the neurovascular bundle. On histologic examination, most tumors were monophasic synovial sarcoma (4/5). At the time of surgery, all tumors were noted to arise along or within a peripheral nerve. All patients were alive with no evidence of disease with median follow-up of 44 (range 32-237) months. For comparison, approximately 775 benign peripheral nerve sheath tumors of the extremities were identified during the same time period. Primary synovial sarcoma of the nerve can mimic peripheral nerve sheath tumors clinically and on imaging and should be included in the differential diagnosis for tumors arising from peripheral nerves. (orig.)

  13. Charge of a macroscopic particle in a plasma sheath

    International Nuclear Information System (INIS)

    Samarian, A.A.; Vladimirov, S.V.

    2003-01-01

    Charging of a macroscopic body levitating in a rf plasma sheath is studied experimentally and theoretically. The nonlinear charge vs size dependence is obtained. The observed nonlinearity is explained on the basis of an approach taking into account different plasma conditions for the levitation positions of different particles. The importance of suprathermal electrons' contribution to the charging process is demonstrated

  14. The Bohm criterion for a dusty plasma sheath

    Indian Academy of Sciences (India)

    undergo temperature fluctuations due to collision, the mean square fluctuation in their temperature is much less than the equilibrium temperature. The problem of sheath dynamics with the plasma–wall interactions is of great importance in a number of areas, viz., plasma ion implantation, high-density com- puter chip ...

  15. Spine Patterning Is Guided by Segmentation of the Notochord Sheath

    NARCIS (Netherlands)

    Wopat, Susan; Bagwell, Jennifer; Sumigray, Kaelyn D.; Dickson, Amy L.; Huitema, Leonie F.A.; Poss, Kenneth D.; Schulte-Merker, Stefan; Bagnat, Michel

    2018-01-01

    The spine is a segmented axial structure made of alternating vertebral bodies (centra) and intervertebral discs (IVDs) assembled around the notochord. Here, we show that, prior to centra formation, the outer epithelial cell layer of the zebrafish notochord, the sheath, segments into alternating

  16. Malignant Peripheral Nerve Sheath Tumor: MRI and CT Findings

    Directory of Open Access Journals (Sweden)

    K. O. Kragha

    2015-01-01

    important in its diagnosis. A rare case of MPNST that produced urinary retention and bowel incontinence is presented that may aid clinicians in the diagnosis of this rare clinical entity. Motor weakness, central enhancement, and immunohistochemistry may assist in the diagnosis of MPNST and differentiation between benign peripheral nerve sheath tumor (BPNST and MPNST.

  17. On the upper bound in the Bohm sheath criterion

    Energy Technology Data Exchange (ETDEWEB)

    Kotelnikov, I. A., E-mail: I.A.Kotelnikov@inp.nsk.su; Skovorodin, D. I., E-mail: D.I.Skovorodin@inp.nsk.su [Russian Academy of Sciences, Budker Institute of Nuclear Physics, Siberian Branch (Russian Federation)

    2016-02-15

    The question is discussed about the existence of an upper bound in the Bohm sheath criterion, according to which the Debye sheath at the interface between plasma and a negatively charged electrode is stable only if the ion flow velocity in plasma exceeds the ion sound velocity. It is stated that, with an exception of some artificial ionization models, the Bohm sheath criterion is satisfied as an equality at the lower bound and the ion flow velocity is equal to the speed of sound. In the one-dimensional theory, a supersonic flow appears in an unrealistic model of a localized ion source the size of which is less than the Debye length; however, supersonic flows seem to be possible in the two- and three-dimensional cases. In the available numerical codes used to simulate charged particle sources with a plasma emitter, the presence of the upper bound in the Bohm sheath criterion is not supposed; however, the correspondence with experimental data is usually achieved if the ion flow velocity in plasma is close to the ion sound velocity.

  18. Electron sheath collapse in an applied-B ion diode

    Energy Technology Data Exchange (ETDEWEB)

    Grechikha, A V [Forschungszentrum Karlsruhe (Germany). Institut fuer Neutronenphysik und Reaktortechnik

    1997-12-31

    The effect of the electron sheath collapse in an applied-B ion diode due to the presence of the resistive anode plasma layer was found. This effect is more damaging at higher diode voltages and may be responsible for the parasitic load effect observed in the experiments. (author). 4 figs., 2 refs.

  19. Internal pressure effects in the AIRCO-LCT conductor sheath

    International Nuclear Information System (INIS)

    Luton, J.N.; Clinard, J.A.; Lue, J.W.; Gray, W.H.; Summers, L.T.; Kershaw, R.

    1985-01-01

    The large Nb 3 Sn superconducting test coil produced by Westinghouse Electric Corporation for the international Large Coil Task (LCT) utilizes a conductor composed of cabled multifilamentary strands immersed in flowing supercritical helium contained by a square structural sheath made of the high-strength stainless alloy JBX-75. Peak pressures of a few hundred atmospheres are predicted to occur during quench, and measurement of these pressures seems feasible only through penetrations of the sheath wall. Fully processed short lengths of conductor were taken from production ends, fitted with pressure taps and strain gauges, and pressurized with helium gas. Failure, at 1000 atm at liquid nitrogen temperature, was by a catastrophic splitting of the sheath at a corner. Strain measurements and burst pressure agreed with elastic-plastic finite element stress calculations made for the sheath alone. Neither the production seam weld nor the pressure tap penetrations or their fillet welds contributed to the failure, although the finite element calculations show that these areas were also highly stressed, and examination of the failed sample showed that the finite welds were of poor quality. Failure was by tensile overload, with no evidence of fatigue

  20. Malignant peripheral nerve sheath tumour of the bladder associated with neurofibromatosis I.

    LENUS (Irish Health Repository)

    O'Brien, Julie

    2008-12-01

    Neurofibromatosis is a hamartomatous disorder of autonomic peripheral nerve sheaths associated with peripheral nerve sheath tumours. Most tumours are neurofibromas; however, the genitourinary system is rarely involved. We present a rare case of a nerve sheath tumour of the bladder in a young patient, which was discovered to be malignant.

  1. 30 CFR 15.32 - Tolerances for weight of explosive, sheath, wrapper, and specific gravity.

    Science.gov (United States)

    2010-07-01

    ..., wrapper, and specific gravity. 15.32 Section 15.32 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION... explosive, sheath, wrapper, and specific gravity. (a) The weight of the explosive, the sheath, and the outer.... (c) The specific gravity of the explosive and sheath shall be within ±7.5 percent of that specified...

  2. File list: His.Neu.50.AllAg.Nerve_Sheath_Neoplasms [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available His.Neu.50.AllAg.Nerve_Sheath_Neoplasms mm9 Histone Neural Nerve Sheath Neoplasms h...ttp://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/His.Neu.50.AllAg.Nerve_Sheath_Neoplasms.bed ...

  3. File list: ALL.Neu.50.AllAg.Nerve_Sheath_Neoplasms [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available ALL.Neu.50.AllAg.Nerve_Sheath_Neoplasms mm9 All antigens Neural Nerve Sheath Neopla...sms SRX337965 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/ALL.Neu.50.AllAg.Nerve_Sheath_Neoplasms.bed ...

  4. File list: Oth.Neu.05.AllAg.Nerve_Sheath_Neoplasms [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Oth.Neu.05.AllAg.Nerve_Sheath_Neoplasms mm9 TFs and others Neural Nerve Sheath Neop...lasms SRX337965 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/Oth.Neu.05.AllAg.Nerve_Sheath_Neoplasms.bed ...

  5. File list: Pol.Neu.50.AllAg.Nerve_Sheath_Neoplasms [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Pol.Neu.50.AllAg.Nerve_Sheath_Neoplasms mm9 RNA polymerase Neural Nerve Sheath Neop...lasms http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/Pol.Neu.50.AllAg.Nerve_Sheath_Neoplasms.bed ...

  6. File list: Oth.Neu.50.AllAg.Nerve_Sheath_Neoplasms [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Oth.Neu.50.AllAg.Nerve_Sheath_Neoplasms mm9 TFs and others Neural Nerve Sheath Neop...lasms SRX337965 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/Oth.Neu.50.AllAg.Nerve_Sheath_Neoplasms.bed ...

  7. File list: Pol.Neu.20.AllAg.Nerve_Sheath_Neoplasms [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Pol.Neu.20.AllAg.Nerve_Sheath_Neoplasms mm9 RNA polymerase Neural Nerve Sheath Neop...lasms http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/Pol.Neu.20.AllAg.Nerve_Sheath_Neoplasms.bed ...

  8. File list: His.Neu.05.AllAg.Nerve_Sheath_Neoplasms [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available His.Neu.05.AllAg.Nerve_Sheath_Neoplasms mm9 Histone Neural Nerve Sheath Neoplasms h...ttp://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/His.Neu.05.AllAg.Nerve_Sheath_Neoplasms.bed ...

  9. File list: Oth.Neu.20.AllAg.Nerve_Sheath_Neoplasms [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Oth.Neu.20.AllAg.Nerve_Sheath_Neoplasms mm9 TFs and others Neural Nerve Sheath Neop...lasms SRX337965 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/Oth.Neu.20.AllAg.Nerve_Sheath_Neoplasms.bed ...

  10. File list: DNS.Neu.10.AllAg.Nerve_Sheath_Neoplasms [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available DNS.Neu.10.AllAg.Nerve_Sheath_Neoplasms mm9 DNase-seq Neural Nerve Sheath Neoplasms... http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/DNS.Neu.10.AllAg.Nerve_Sheath_Neoplasms.bed ...

  11. File list: Unc.Neu.50.AllAg.Nerve_Sheath_Neoplasms [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Unc.Neu.50.AllAg.Nerve_Sheath_Neoplasms mm9 Unclassified Neural Nerve Sheath Neopla...sms http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/Unc.Neu.50.AllAg.Nerve_Sheath_Neoplasms.bed ...

  12. File list: DNS.Neu.05.AllAg.Nerve_Sheath_Neoplasms [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available DNS.Neu.05.AllAg.Nerve_Sheath_Neoplasms mm9 DNase-seq Neural Nerve Sheath Neoplasms... http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/DNS.Neu.05.AllAg.Nerve_Sheath_Neoplasms.bed ...

  13. File list: ALL.Neu.20.AllAg.Nerve_Sheath_Neoplasms [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available ALL.Neu.20.AllAg.Nerve_Sheath_Neoplasms mm9 All antigens Neural Nerve Sheath Neopla...sms SRX337965 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/ALL.Neu.20.AllAg.Nerve_Sheath_Neoplasms.bed ...

  14. File list: Pol.Neu.10.AllAg.Nerve_Sheath_Neoplasms [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Pol.Neu.10.AllAg.Nerve_Sheath_Neoplasms mm9 RNA polymerase Neural Nerve Sheath Neop...lasms http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/Pol.Neu.10.AllAg.Nerve_Sheath_Neoplasms.bed ...

  15. File list: Unc.Neu.05.AllAg.Nerve_Sheath_Neoplasms [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Unc.Neu.05.AllAg.Nerve_Sheath_Neoplasms mm9 Unclassified Neural Nerve Sheath Neopla...sms http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/Unc.Neu.05.AllAg.Nerve_Sheath_Neoplasms.bed ...

  16. File list: DNS.Neu.50.AllAg.Nerve_Sheath_Neoplasms [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available DNS.Neu.50.AllAg.Nerve_Sheath_Neoplasms mm9 DNase-seq Neural Nerve Sheath Neoplasms... http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/DNS.Neu.50.AllAg.Nerve_Sheath_Neoplasms.bed ...

  17. File list: DNS.Neu.20.AllAg.Nerve_Sheath_Neoplasms [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available DNS.Neu.20.AllAg.Nerve_Sheath_Neoplasms mm9 DNase-seq Neural Nerve Sheath Neoplasms... http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/DNS.Neu.20.AllAg.Nerve_Sheath_Neoplasms.bed ...

  18. File list: His.Neu.20.AllAg.Nerve_Sheath_Neoplasms [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available His.Neu.20.AllAg.Nerve_Sheath_Neoplasms mm9 Histone Neural Nerve Sheath Neoplasms h...ttp://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/His.Neu.20.AllAg.Nerve_Sheath_Neoplasms.bed ...

  19. File list: Oth.Neu.10.AllAg.Nerve_Sheath_Neoplasms [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Oth.Neu.10.AllAg.Nerve_Sheath_Neoplasms mm9 TFs and others Neural Nerve Sheath Neop...lasms SRX337965 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/Oth.Neu.10.AllAg.Nerve_Sheath_Neoplasms.bed ...

  20. File list: ALL.Neu.10.AllAg.Nerve_Sheath_Neoplasms [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available ALL.Neu.10.AllAg.Nerve_Sheath_Neoplasms mm9 All antigens Neural Nerve Sheath Neopla...sms SRX337965 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/ALL.Neu.10.AllAg.Nerve_Sheath_Neoplasms.bed ...

  1. File list: Unc.Neu.20.AllAg.Nerve_Sheath_Neoplasms [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Unc.Neu.20.AllAg.Nerve_Sheath_Neoplasms mm9 Unclassified Neural Nerve Sheath Neopla...sms http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/Unc.Neu.20.AllAg.Nerve_Sheath_Neoplasms.bed ...

  2. File list: His.Neu.10.AllAg.Nerve_Sheath_Neoplasms [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available His.Neu.10.AllAg.Nerve_Sheath_Neoplasms mm9 Histone Neural Nerve Sheath Neoplasms h...ttp://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/His.Neu.10.AllAg.Nerve_Sheath_Neoplasms.bed ...

  3. File list: Pol.Neu.05.AllAg.Nerve_Sheath_Neoplasms [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Pol.Neu.05.AllAg.Nerve_Sheath_Neoplasms mm9 RNA polymerase Neural Nerve Sheath Neop...lasms http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/Pol.Neu.05.AllAg.Nerve_Sheath_Neoplasms.bed ...

  4. File list: ALL.Neu.05.AllAg.Nerve_Sheath_Neoplasms [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available ALL.Neu.05.AllAg.Nerve_Sheath_Neoplasms mm9 All antigens Neural Nerve Sheath Neopla...sms SRX337965 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/ALL.Neu.05.AllAg.Nerve_Sheath_Neoplasms.bed ...

  5. A Tendon Cell Specific RNAi Screen Reveals Novel Candidates Essential for Muscle Tendon Interaction.

    Directory of Open Access Journals (Sweden)

    Prabhat Tiwari

    Full Text Available Tendons are fibrous connective tissue which connect muscles to the skeletal elements thus acting as passive transmitters of force during locomotion and provide appropriate body posture. Tendon-derived cues, albeit poorly understood, are necessary for proper muscle guidance and attachment during development. In the present study, we used dorsal longitudinal muscles of Drosophila and their tendon attachment sites to unravel the molecular nature of interactions between muscles and tendons. We performed a genetic screen using RNAi-mediated knockdown in tendon cells to find out molecular players involved in the formation and maintenance of myotendinous junction and found 21 candidates out of 2507 RNAi lines screened. Of these, 19 were novel molecules in context of myotendinous system. Integrin-βPS and Talin, picked as candidates in this screen, are known to play important role in the cell-cell interaction and myotendinous junction formation validating our screen. We have found candidates with enzymatic function, transcription activity, cell adhesion, protein folding and intracellular transport function. Tango1, an ER exit protein involved in collagen secretion was identified as a candidate molecule involved in the formation of myotendinous junction. Tango1 knockdown was found to affect development of muscle attachment sites and formation of myotendinous junction. Tango1 was also found to be involved in secretion of Viking (Collagen type IV and BM-40 from hemocytes and fat cells.

  6. Motor responses to experimental Achilles tendon pain

    DEFF Research Database (Denmark)

    Henriksen, Marius; Aaboe, Jens; Graven-Nielsen, Thomas

    2011-01-01

    of the exercise are affected by Achilles tendon pain. Objective The authors aimed to determine the effects of experimental Achilles tendon pain on motor function during one-legged weight bearing ankle plantar and dorsal flexion exercises. Methods In a crossover study, with 16 healthy subjects tested on two......Background Achilles tendinopathies are characterised by pain and reduced function, and heavy-load exercises have been shown to be effective in the treatment of painful chronic Achilles tendinopathies. However, basic information is needed on how the biomechanics and neuromuscular control...... different days separated by 1 week, three-dimensional ground reaction forces, ankle joint kinematics and surface electromyography (EMG) of the lower leg muscles were recorded during one-legged full weight-bearing ankle plantar (concentric) and dorsal (eccentric) flexion exercises. Measurements were done...

  7. A passive exoskeleton with artificial tendons: design and experimental evaluation.

    Science.gov (United States)

    van Dijk, Wietse; van der Kooij, Herman; Hekman, Edsko

    2011-01-01

    We developed a passive exoskeleton that was designed to minimize joint work during walking. The exoskeleton makes use of passive structures, called artificial tendons, acting in parallel with the leg. Artificial tendons are elastic elements that are able to store and redistribute energy over the human leg joints. The elastic characteristics of the tendons have been optimized to minimize the mechanical work of the human leg joints. In simulation the maximal reduction was 40 percent. The performance of the exoskeleton was evaluated in an experiment in which nine subjects participated. Energy expenditure and muscle activation were measured during three conditions: Normal walking, walking with the exoskeleton without artificial tendons, and walking with the exoskeleton with the artificial tendons. Normal walking was the most energy efficient. While walking with the exoskeleton, the artificial tendons only resulted in a negligibly small decrease in energy expenditure. © 2011 IEEE

  8. Imaging the infrapatellar tendon in the elite athlete

    International Nuclear Information System (INIS)

    Peace, K.A.L.; Lee, J.C.; Healy, J.

    2006-01-01

    Extensor mechanism injuries constitute a major cause of anterior knee pain in the elite athlete. Sonography and magnetic resonance imaging (MRI) are the imaging methods of choice when assessing the infrapatellar tendon. A comprehensive imaging review of infrapatellar tendon normal anatomy, tendinopathy, and partial/full-thickness tendon tears is provided. The value of imaging the infrapatellar tendon in clinical practice, including whether sonography can predict symptoms in asymptomatic athletes, is discussed. Acute avulsion fractures, including periosteal sleeve avulsion, and chronic avulsion injuries, including Sinding-Larsen-Johansson and Osgood-Schlatter syndromes, are shown. Mimics of infrapatellar tendon pathology, including infrapatellar plica injury, patellar tendon-lateral femoral condyle friction syndrome, and Hoffa's syndrome, are illustrated

  9. About tendon tissue regeneration in experimental radiation disease

    Energy Technology Data Exchange (ETDEWEB)

    Popov, D; Trichkova, P

    1976-01-01

    Under the conditions of experimental acute radiation disease the authors study the tendon tissue regeneration after suture of the lateral part of the gastrocnemius muscle tendon. Tendon auto and alloplasty were applied. In four postoperative periods the histological features are described in details as well as the characteristic phenomena observed during the regeneration influenced to a considerable degree by the irradiation. Round cell infiltration, large necrotic zones, erythrocyte infiltrations as well as predominance of non-specific tendon regeneration long after the surgery characterize the recovery period of the traumatically damaged tendon, nevertheless that at the end there is real tendon regeneration even though in a longer period in comparison with the controls (non-irradiated animals).

  10. Calcaneal Tendon Collagen Fiber Morphometry and Aging

    Czech Academy of Sciences Publication Activity Database

    Hadraba, Daniel; Janáček, Jiří; Filová, Eva; Lopot, F.; Paesen, R.; Fanta, O.; Jarman, A.; Nečas, A.; Ameloot, M.; Jelen, K.

    2017-01-01

    Roč. 23, č. 5 (2017), s. 1040-1047 ISSN 1431-9276 R&D Projects: GA ČR(CZ) GA16-14758S; GA MŠk(CZ) LO1309; GA MŠk(CZ) LM2015062 Institutional support: RVO:67985823 ; RVO:68378041 Keywords : collagen * aging * crimp * fiber orientation * tendon Subject RIV: EB - Genetics ; Molecular Biology; BO - Biophysics (UEM-P) OBOR OECD: Developmental biology; Biophysics (UEM-P) Impact factor: 1.891, year: 2016

  11. An artificial tendon with durable muscle interface.

    Science.gov (United States)

    Melvin, Alan; Litsky, Alan; Mayerson, Joel; Witte, David; Melvin, David; Juncosa-Melvin, Natalia

    2010-02-01

    A coupling mechanism that can permanently fix a forcefully contracting muscle to a bone anchor or any totally inert prosthesis would meet a serious need in orthopaedics. Our group developed the OrthoCoupler device to satisfy these demands. The objective of this study was to test OrthoCoupler's performance in vitro and in vivo in the goat semitendinosus tendon model. For in vitro evaluation, 40 samples were fatigue-tested, cycling at 10 load levels, n = 4 each. For in vivo evaluation, the semitendinosus tendon was removed bilaterally in eight goats. Left sides were reattached with an OrthoCoupler, and right sides were reattached using the Krackow stitch with #5 braided polyester sutures. Specimens were harvested 60 days postsurgery and assigned for biomechanics and histology. Fatigue strength of the devices in vitro was several times the contractile force of the semitendinosus muscle. The in vivo devices were built equivalent to two of the in vitro devices, providing an additional safety factor. In strength testing at necropsy, suture controls pulled out at 120.5 +/- 68.3 N, whereas each OrthoCoupler was still holding after the muscle tore, remotely, at 298 +/- 111.3 N (mean +/- SD) (p < 0.0003). Muscle tear strength was reached with the fiber-muscle composite produced in healing still soundly intact. This technology may be of value for orthopaedic challenges in oncology, revision arthroplasty, tendon transfer, and sports-injury reconstruction. (c) 2009 Orthopaedic Research Society.

  12. Arthroscopically-Asissted Achilles Tendon Repair; Long-Term Results

    OpenAIRE

    Turgut, Ak?n; Asfuro?lu, Mert Zeynel

    2014-01-01

    Objectives: The ruptures of the Achilles tendon (AT) are relatively common. Since there is no consensus on the best method of the repair of the AT; the treatment is determined on the preference of the surgeon and the patient. The study evaluating the cadaveric and short term clinical results done by our clinic in 2002, has shown us that arthroscopically Achilles tendon repair can be good choise in achilles tendon ruptures. Methods: Fortyfour patients who underwent arthroscopically assisted ac...

  13. Reconstruction of Ligament and Tendon Defects Using Cell Technologies.

    Science.gov (United States)

    Chailakhyan, R K; Shekhter, A B; Ivannikov, S V; Tel'pukhov, V I; Suslin, D S; Gerasimov, Yu V; Tonenkov, A M; Grosheva, A G; Panyushkin, P V; Moskvina, I L; Vorob'eva, N N; Bagratashvili, V N

    2017-02-01

    We studied the possibility of restoring the integrity of the Achilles tendon in rabbits using autologous multipotent stromal cells. Collagen or gelatin sponges populated with cells were placed in a resorbable Vicryl mesh tube and this tissue-engineered construct was introduced into a defect of the middle part of the Achilles tendon. In 4 months, histological analysis showed complete regeneration of the tendon with the formation of parallel collagen fibers, spindle-shaped tenocytes, and newly formed vessels.

  14. 77 FR 69508 - Inservice Inspection of Prestressed Concrete Containment Structures With Grouted Tendons

    Science.gov (United States)

    2012-11-19

    ... Containment Structures With Grouted Tendons AGENCY: Nuclear Regulatory Commission. ACTION: Regulatory guide... (RG) 1.90, ``Inservice Inspection of Prestressed Concrete Containment Structures with Grouted Tendons... appropriate surveillance program for prestressed concrete containment structures with grouted tendons...

  15. Nanoparticles for tendon healing and regeneration: literature review.

    Directory of Open Access Journals (Sweden)

    Paolo Domenico Parchi

    2016-08-01

    Full Text Available Tendon injuries are commonly met in the emergency department. Unfortunately, tendon tissue has limited regeneration potential and usually the consequent formation of scar tissue causes inferior mechanical properties Nanoparticles could be used in different way to improve tendon healing and regeneration, ranging from scaffolds manufacturing (increasing the strength and endurance or anti-adhesions, anti-microbial and anti-inflammatory properties to gene therapy. This paper aims to summarize the most relevant studies showing the potential application of nanoparticles for tendon tissue regeneration

  16. Tendon synovial cells secrete fibronectin in vivo and in vitro

    International Nuclear Information System (INIS)

    Banes, A.J.; Link, G.W.; Bevin, A.G.; Peterson, H.D.; Gillespie, Y.; Bynum, D.; Watts, S.; Dahners, L.

    1988-01-01

    The chemistry and cell biology of the tendon have been largely overlooked due to the emphasis on collagen, the principle structural component of the tendon. The tendon must not only transmit the force of muscle contraction to bone to effect movement, but it must also glide simultaneously over extratendonous tissues. Fibronectin is classified as a cell attachment molecule that induces cell spreading and adhesion to substratum. The external surface of intact avian flexor tendon stained positively with antibody to cellular fibronectin. However, if the surface synovial cells were first removed with collagenase, no positive reaction with antifibronectin antibody was detected. Analysis of immunologically stained frozen sections of tendon also revealed fibronectin at the tendon synovium, but little was associated with cells internal in tendon. The staining pattern with isolated, cultured synovial cells and fibroblasts from the tendon interior substantiated the histological observations. Analysis of polyacrylamide gel profiles of 35 S-methionine-labeled proteins synthesized by synovial cells and internal fibroblasts indicated that fibronectin was synthesized principally by synovial cells. Fibronectin at the tendon surface may play a role in cell attachment to prevent cell removal by the friction of gliding. Alternatively, fibronectin, with its binding sites for hyaluronic acid and collagen, may act as a complex for boundary lubrication

  17. Magnetic resonance imaging and computed radiography in Achilles tendon rupture

    International Nuclear Information System (INIS)

    Korenaga, Tateo; Hachiya, Junichi; Miyasaka, Yasuo

    1988-01-01

    Magnetic Resonance Imaging (MRI) and Computed Radiography (CR) were performed in 15 patients with complete Achilles tendon rupture who were treated conservatively without surgery. MRI was obtained using Toshiba MRT 50 A superconductive machine, operaing at 0.5 Tesla. CR was performed by CR-101, Fuji Medical System. In fresh cases, ruptured tendons showed intermediate signal intensity on T1-weighted images and high intensity on T2-weighted images. Thickening of the tendon was observed in all cases except in very acute stage. Configuration of thickend tendons tends to be dumbbell shape in subacute stage and fusiform in chronic stage of more than six months after the initial trauma. In cases which showed high signal intensity at the ruptured area both on T1 and T2 weighted images, migration of fat into the sapces between the ruptured tendons was considered to be the major source of increased signal intensity. Computed radiography showed thickening of the tendon, blurring of anterior margin of the tendon, and decreased translucency of pre-Achilles fat pad. However, MRI better demonstrated the details of ruptured tendons when compared to CR, and thought to be an usefull way of following up the healing process of the ruptured tendon to facilitate more reasonable judgement of the time of removing plaster casts and stating exercise. (author)

  18. Ossification of the bilateral Achilles tendon: a rare entity

    International Nuclear Information System (INIS)

    Arora, Abhishek J; Arora, Richa

    2015-01-01

    Ossification of the Achilles tendon is a rare clinical entity comprising of one or more segments of variable sized ossified masses in the fibrocartilaginous substance of the tendon. The etiology of ossification of the Achilles tendon is multifactorial with recurrent trauma and surgery comprising major predisposing factors, with others being metabolic, systemic, and infectious diseases. The possibility of a genetic predisposition towards this entity has also been raised, but has not yet been proven. We present a rare case of ossification of the bilateral Achilles tendons without any history of trauma or surgery in a 48-year-old female patient

  19. Biology and augmentation of tendon-bone insertion repair

    Directory of Open Access Journals (Sweden)

    Lui PPY

    2010-08-01

    Full Text Available Abstract Surgical reattachment of tendon and bone such as in rotator cuff repair, patellar-patella tendon repair and anterior cruciate ligament (ACL reconstruction often fails due to the failure of regeneration of the specialized tissue ("enthesis" which connects tendon to bone. Tendon-to-bone healing taking place between inhomogenous tissues is a slow process compared to healing within homogenous tissue, such as tendon to tendon or bone to bone healing. Therefore special attention must be paid to augment tendon to bone insertion (TBI healing. Apart from surgical fixation, biological and biophysical interventions have been studied aiming at regeneration of TBI healing complex, especially the regeneration of interpositioned fibrocartilage and new bone at the healing junction. This paper described the biology and the factors influencing TBI healing using patella-patellar tendon (PPT healing and tendon graft to bone tunnel healing in ACL reconstruction as examples. Recent development in the improvement of TBI healing and directions for future studies were also reviewed and discussed.

  20. Numerical models for prestressing tendons in containment structures

    International Nuclear Information System (INIS)

    Kwak, Hyo-Gyoung; Kim, Jae Hong

    2006-01-01

    Two modified stress-strain relations for bonded and unbonded internal tendons are proposed. The proposed relations can simulate the post-cracking behavior and tension stiffening effect in prestressed concrete containment structures. In the case of the bonded tendon, tensile forces between adjacent cracks are transmitted from a bonded tendon to concrete by bond forces. Therefore, the constitutive law of a bonded tendon stiffened by grout needs to be determined from the bond-slip relationship. On the other hand, a stress increase beyond the effective prestress in an unbonded tendon is not section-dependent but member-dependent. It means that the tendon stress unequivocally represents a uniform distribution along the length when the friction loss is excluded. Thus, using a strain reduction factor, the modified stress-strain curve of an unbonded tendon is derived by successive iterations. In advance, the prediction of cracking behavior and ultimate resisting capacity of prestressed concrete containment structures using the introduced numerical models are succeeded, and the need for the consideration of many influencing factors such as the tension stiffening effect, plastic hinge length and modification of stress-strain relation of tendon is emphasized. Finally, the developed numerical models are applied to prestressed concrete containment structures to verify the efficiency and applicability in simulating the structural behavior with bonded and/or unbonded tendons