WorldWideScience

Sample records for biased electrode experiment

  1. Dual-electrode biasing experiments in KT-5C device

    International Nuclear Information System (INIS)

    Yu Yi; Lu Ronghua; Wang Chen; Pan Geshen; Wen Yizhi; Yu Changxuan; Ma Jinxiu; Wan Shude; Liu Wandong

    2005-01-01

    Based on the single biasing electrode experiments to optimize the confinement of plasma in the device of KT-5C tokamak, dual-biasing electrodes were inserted into the KT5C plasma for the first time to explore the enhancement of the effects of biasing and the mechanisms of the biasing. By means of applying different combinations of biasing voltages to the dual electrodes, the changes in E r , which is the key factor for boosting up the Er x B flow shear, were observed. The time evolution showed the inner electrode played a major role in dual-biasing, for it always drew a larger current than the outer one. The outer electrode made little influence. It turned out that the dual-biasing electrodes were as effective as a single one, in improving plasma confinement, for the mechanism of biasing was essentially an edge effect. (author)

  2. Diagnostics for the Biased Electrode Experiment on NSTX

    International Nuclear Information System (INIS)

    Roquemore, A.L.; Zweben, S.J.; Bush, C.E.; Kaita, R.; Marsalsa, R.J.; Maqueda, R.J.

    2009-01-01

    A linear array of four small biased electrodes was installed in NSTX in an attempt to control the width of the scrape-off layer (SOL) by creating a strong local poloidal electric field. The set of electrodes were separated poloidally by a 1 cm gap between electrodes and were located slightly below the midplane of NSTX, 1 cm behind the RF antenna and oriented so that each electrode is facing approximately normal to the magnetic field. Each electrode can be independently biased to ± 100 volts. Present power supplies limit the current on two electrodes to 30 amps the other two to 10 amps each. The effect of local biasing was measured with a set of Langmuir probes placed between the electrodes and another set extending radially outward from the electrodes, and also by the gas puff imaging diagnostic (GPI) located 1 m away along the magnetic field lines intersecting the electrodes. Two fast cameras were also aimed directly at the electrode array. The hardware and controls of the biasing experiment will be presented and the initial effects on local plasma parameters will be discussed

  3. Electrode and limiter biasing experiments on the tokamak ISTTOK

    International Nuclear Information System (INIS)

    Silva, C.; Figueiredo, H.; Cabral, J.A.C.; Nedzelsky, I.; Varandas, C.A.F.

    2003-01-01

    In this contribution limiter and electrode biasing experiments are compared, in particular in what concerns their effects on the edge plasma parameters. For electrode AC bias a substantial increase (>50%) in the average plasma density is observed with positive voltage, without significant changes in the edge density, leading to steeper profiles. The ratio n e /Hα also increases significantly (>20%), indicating an improvement in gross particle confinement. The plasma potential profile is strongly modified as both the edge E r and its shear increase significantly. For positive limiter bias an increase in the average plasma density and the radiation losses is observed, resulting in almost no modification, or a slight, in particle confinement. Preliminary results of simultaneous electrode and limiter bias experiments show that the control of the plasma potential profile is very limited, since negative voltages do not modify the plasma parameters significantly. (author)

  4. Observation of intermittent transition by electrode biasing in Heliotron J

    International Nuclear Information System (INIS)

    Shimizu, Kosuke; Kitajima, Sumio; Okamoto, Atsushi

    2015-01-01

    We observed intermittent increases in the electrode current in electrode biasing experiments in Heliotron J. In addition, electron density and floating potential showed pulsating behavior associated with the electrode current. The relation between line density and electrode current and that between floating potential and electrode current showed a hysteresis feature in transitions. Then it is evident that the pulsating behavior was the intermittent transition between two distinctive states. We also observed the mode (∼10 kHz) that accompanied the pulsating behavior in the power spectrum density of the floating potential and ion saturation current obtained via fast Fourier transform. The electron density gradient increased, and subsequently the power spectrum density of the fluctuation increased. (author)

  5. Plasma confinement using biased electrode in the TCABR tokamak

    International Nuclear Information System (INIS)

    Nascimento, I.C.; Kuznetsov, Y.K.; Severo, J.H.F.; Fonseca, A.M.M.; Elfimov, A.; Bellintani, V.; Machida, M.; Heller, M.V.A.P.; Galvao, R.M.O.; Sanada, E.K.; Elizondo, J.I.

    2005-01-01

    Experimental data obtained on the TCABR tokamak (R = 0.61 m, a = 0.18 m) with an electrically polarized electrode, placed at r = 0.16 m, is reported in this paper. The experiment was performed with plasma current of 90 kA (q 3.1) and hydrogen gas injection adjusted for keeping the electron density at 1.0 x 10 19 m -3 without bias. Time evolution and radial profiles of plasma parameters with and without bias were measured. The comparison of the profiles shows an increase of the central line-averaged density, up to a maximum factor of 2.6, while H α hydrogen spectral line intensity decreases and the C III impurity stays on the same level. The analysis of temporal behaviour and radial profiles of plasma parameters indicates that the confined plasma enters the H-mode regime. The data analysis shows a maximum enhanced energy confinement factor of 1.95, decaying to 1.5 at the maximum of the density, in comparison with predicted Neo-Alcator scaling law values. Indications of transient increase of the density gradient near the plasma edge were obtained with measurements of density profiles. Calculations of turbulence and transport at the Scrape-Off-Layer, using measured floating potentials and ion saturation currents, show a strong decrease in the power spectra and transport. Bifurcation was not observed and the decrease in the saturation current occurs in 50 μs

  6. Plasma confinement using biased electrode in the TCABR tokamak

    International Nuclear Information System (INIS)

    Nascimento, I.C.; Kuznetsov, Y.K.; Severo, J.H.F.; Fonseca, A.M.M.; Elfimov, A.; Bellintani, V.; Heller, M.V.A.P.; Galvao, R.M.O.; Sanada, E.K.; Elizondo, J.I.; Machida, M.

    2005-01-01

    Experimental data obtained on the TCABR tokamak (R = 0.61 m, r = 0.18 m) with an electrally polarized electrode, placed at r = 0.16 m, is reported in this paper. The experiment was performed with plasma current of 90 kA (q 3.1), and hydrogen gas injection adjusted for keeping the electron density at 1.0x10(19) m(-3) without bias. Temporal and radial profiles of plasma parameters with and without bias were measured. The comparison of the profiles shows an increase of the density, up to a maximum factor of 2.6, while H-alpha hydrogen spectral line intensity decreases, and the CIII impurity stays on the same level. The analysis of temporal and radial profiles of plasma parameters indicates that the confined plasma entered in the H-mode regime. The data analysis shows a maximum enhanced confinement factor of 1.95, decaying to 1.5 at the maximum of the density, in comparison with predicted Neo-Alcator scaling law values. Indications of transient increase of the density gradient near the plasma edge were obtained with measurements of density profiles. Calculations of turbulence and transport at the plasma edge, using measured floating potentials and ion saturation currents, show strong decrease in the power spectra and transport. Bifurcation was not observed, and the decrease in the saturation current occurs in 50 microseconds. (author)

  7. Biased limiter experiments on text

    International Nuclear Information System (INIS)

    Phillips, P.E.; Wootton, A.J.; Rowan, W.L.; Ritz, C.P.; Rhodes, T.L.; Bengtson, R.D.; Hodge, W.L.; Durst, R.D.; McCool, S.C.; Richards, B.; Gentle, K.W.; Schoch, P.; Forster, J.C.; Hickok, R.L.; Evans, T.E.

    1987-01-01

    Experiments using an electrically biased limiter have been performed on the Texas Experimental Tokamak (TEXT). A small movable limiter is inserted past the main poloidal ring limiter (which is electrically connected to the vacuum vessel) and biased at V Lim with respect to it. The floating potential, plasma potential and shear layer position can be controlled. With vertical strokeV Lim vertical stroke ≥ 50 V the plasma density increases. For V Lim Lim > 0 the results obtained are inconclusive. Variation of V Lim changes the electrostatic turbulence which may explain the observed total flux changes. (orig.)

  8. Transition of poloidal viscosity by electrode biasing in the Large Helical Device

    International Nuclear Information System (INIS)

    Kitajima, S.; Ishii, K.; Sato, Y.; Kanno, M.; Tachibana, J.; Okamoto, A.; Sasao, M.; Takahashi, H.; Masuzaki, S.; Shoji, M.; Ashikawa, N.; Tokitani, M.; Yokoyama, M.; Suzuki, Y.; Satake, S.; Ido, T.; Shimizu, A.; Suzuki, C.; Inagaki, S.; Takayama, M.

    2013-01-01

    Electrode biasing experiments were carried out in various magnetic configurations on the Large Helical Device (LHD). The transitions of poloidal viscosity, which were accompanied with bifurcation phenomena characterized by a negative resistance in an electrode characteristic, were clearly observed on LHD by the electrode biasing. The critical external driving force required for transition was compared with the local maximum in ion viscosity, and the radial resistivity before the transition also compared with the expected value from a neoclassical theory. The critical driving force increased and the radial resistivity decreased with the major radius of the magnetic axis R ax going outwards. The configuration dependence of the transition condition and the radial resistivity qualitatively agreed with neoclassical theories. The radial electric field and the viscosity were also evaluated by the neoclassical transport code for a non-axisymmetric system, and estimated electrode voltage required for the transition, which was consistent with the experimental results. (paper)

  9. Low-bias negative differential conductance controlled by electrode separation

    Science.gov (United States)

    Yi, Xiao-Hua; Liu, Ran; Bi, Jun-Jie; Jiao, Yang; Wang, Chuan-Kui; Li, Zong-Liang

    2016-12-01

    The electronic transport properties of a single thiolated arylethynylene molecule with 9,10-dihydroanthracene core, denoted as TADHA, is studied by using non-equilibrium Green’s function formalism combined with ab initio calculations. The numerical results show that the TADHA molecule exhibits excellent negative differential conductance (NDC) behavior at lower bias regime as probed experimentally. The NDC behavior of TADHA molecule originates from the Stark effect of the applied bias voltage, by which the highest occupied molecular orbital (HOMO) and the HOMO-1 are pulled apart and become localized. The NDC behavior of TADHA molecular system is tunable by changing the electrode distance. Shortening the electrode separation can enhance the NDC effect which is attributed to the possible increase of coupling between the two branches of TADHA molecule. Project supported by the National Natural Science Foundation of China (Grant Nos. 11374195 and 11405098) and the Natural Science Foundation of Shandong Province, China (Grant No. ZR2013FM006).

  10. Low-bias negative differential conductance controlled by electrode separation

    International Nuclear Information System (INIS)

    Yi Xiao-Hua; Liu Ran; Bi Jun-Jie; Jiao Yang; Wang Chuan-Kui; Li Zong-Liang

    2016-01-01

    The electronic transport properties of a single thiolated arylethynylene molecule with 9,10-dihydroanthracene core, denoted as TADHA, is studied by using non-equilibrium Green’s function formalism combined with ab initio calculations. The numerical results show that the TADHA molecule exhibits excellent negative differential conductance (NDC) behavior at lower bias regime as probed experimentally. The NDC behavior of TADHA molecule originates from the Stark effect of the applied bias voltage, by which the highest occupied molecular orbital (HOMO) and the HOMO-1 are pulled apart and become localized. The NDC behavior of TADHA molecular system is tunable by changing the electrode distance. Shortening the electrode separation can enhance the NDC effect which is attributed to the possible increase of coupling between the two branches of TADHA molecule. (paper)

  11. Development of a power electrode for plasma biasing on RFX

    International Nuclear Information System (INIS)

    Desideri, D.; Lorenzi, A. de; Zaccaria, P.

    1999-01-01

    A movable power electrode has been developed on the RFX experiment to modify the radial electric field at the edge of the plasma configuration. The electrode insertion head is a mushroom shaped limiter made of a carbon-carbon composite, and boron nitride is used as insulating material to be exposed to the plasma. The power electrode is designed to carry a 10 kA impulsive current and is insulated for 10 kV DC. The current into the electrode is driven by a power supply based on capacitor banks, and protective actions to cope with fault conditions have been implemented. The design of the electrode supporting structure has been done by using 3D finite element analyses, performed to evaluate the dynamic response of the system subjected to impulsive electromagnetic loads. The system has been used on the RFX experiment, showing the expected capability and flexibility. The current and voltage electrode waveforms are reported and discussed as far as the experimental results are concerned. Displacements of the electrode stiffening structure under electromagnetic load have been measured and compared to the numerical results. (orig.)

  12. Transition of poloidal viscosity by electrode biasing in the Large Helical Device

    International Nuclear Information System (INIS)

    Kitajima, S.; Ishii, K.; Takahashi, H.

    2012-11-01

    Electrode biasing experiments were tried in various magnetic configurations on the Large Helical Device (LHD). The transitions of poloidal viscosity, which were accompanied with bifurcation phenomena characterized by a negative resistance, were clearly observed on LHD by the electrode biasing. The critical external driving force required for transition were compared with the local maximum in ion viscosity, and the radial resistivity before the transition also compared with the expected value from a neoclassical theory. The critical driving force increased and the radial resistivity decreased with the major radius of the magnetic axis R ax going outward. The configuration dependence of the transition condition and the radial resistivity qualitatively agreed with neoclassical theories. The radial electric field and the viscosity were also evaluated by the neoclassical transport code for a non-axisymmetric system, and estimated electrode voltage required for the transition, which was consistent with the experimental results. (author)

  13. Hot Cathode Biasing Experiment in Compact Helical System

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, H.; Utoh, H.; Kitajima, S.; Isobe, M.; Suzuki, C.; Takeuchi, M.; Ikeda, R.; Tanaka, Y.; Yokoyama, M.; Toi, K.; Okamura, S.; Sasao, M.

    2005-07-01

    One of the H mode characteristics is a sudden formation of a radial electric field at LH transition. To date, H mode was widely observed in various tokamaks [1-3] and stellarator devices [4, 5], and the importance of the radial electric field has been shown in both experiments and in theory. However, it is difficult to investigate the behaviour of a radial electric field in detail at LH transition induced by NBI heating because the radial electric field is self-organised and changes suddenly. Electrode bias experiments are methods for active control of the radial electric field. The electrode bias experiment has the advantage of the ability to control the radial electric field externally by controlling the electrode voltage and/or the electrode current and to estimate the driving force from the electrode current. The neoclassical theory indicates the criterion of LH transition from the viewpoint of the ion viscosity. In this theory, the ion viscosity has local maxima against the rotation velocity [6-8]. When the driving force in the poloidal direction exceeds a critical value, the poloidal rotation velocity increases rapidly and the plasma undergoes a transition to the H mode. This means that the LH transition mechanism is a bifurcation phenomenon due to the existence of local maxima in the ion viscosity. Here, we carried out the electrode biasing experiment in TU-Heliac and CHS to investigate the effect of ripple structure on ion viscosity and to clarify the role of ion viscosity in triggering the transition from the degraded state to enhanced confinement. (Author)

  14. Reducing status quo bias in choice experiments

    DEFF Research Database (Denmark)

    Bonnichsen, Ole; Ladenburg, Jacob

    In stated preference literature, the tendency to choose the alternative representing the status quo situation seems to exceed real life status quo effects. Accordingly, status quo bias can be a problem. In Choice Experiments, status quo bias is found to be strongly correlated with protest attitudes...... toward the cost attribute. If economic values are to be elicited, this problem is difficult to remedy. In a split sample framework we test a novel ex-ante entreaty aimed specifically at the cost attribute and find that it effectively reduces status quo bias and improves the internal validity...

  15. Response of the plasma to the size of an anode electrode biased near the plasma potential

    International Nuclear Information System (INIS)

    Barnat, E. V.; Laity, G. R.; Baalrud, S. D.

    2014-01-01

    As the size of a positively biased electrode increases, the nature of the interface formed between the electrode and the host plasma undergoes a transition from an electron-rich structure (electron sheath) to an intermediate structure containing both ion and electron rich regions (double layer) and ultimately forms an electron-depleted structure (ion sheath). In this study, measurements are performed to further test how the size of an electron-collecting electrode impacts the plasma discharge the electrode is immersed in. This is accomplished using a segmented disk electrode in which individual segments are individually biased to change the effective surface area of the anode. Measurements of bulk plasma parameters such as the collected current density, plasma potential, electron density, electron temperature and optical emission are made as both the size and the bias placed on the electrode are varied. Abrupt transitions in the plasma parameters resulting from changing the electrode surface area are identified in both argon and helium discharges and are compared to the interface transitions predicted by global current balance [S. D. Baalrud, N. Hershkowitz, and B. Longmier, Phys. Plasmas 14, 042109 (2007)]. While the size-dependent transitions in argon agree, the size-dependent transitions observed in helium systematically occur at lower electrode sizes than those nominally derived from prediction. The discrepancy in helium is anticipated to be caused by the finite size of the interface that increases the effective area offered to the plasma for electron loss to the electrode

  16. High plasma rotation velocity and density transitions by biased electrodes in RF produced, magnetized plasma

    International Nuclear Information System (INIS)

    Matsuyama, Shoichiro; Shinohara, Shunjiro

    2001-01-01

    A large density profile modification was successfully obtained by voltage biasing to electrodes inserted in a RF (radio frequency) produced, magnetized plasma, and formation of strong shear of azimuthal plasma rotation velocity in a supersonic regime was found. For the case of biasing to an electrode near the central plasma region, two types of density transitions were observed in the outer plasma region: one was an oscillatory transition between two states, and the other was a transition from high to low density states with a large reduction of density fluctuations. (author)

  17. High plasma rotation velocity and density transitions by biased electrodes in RF produced, magnetized plasma

    Energy Technology Data Exchange (ETDEWEB)

    Matsuyama, Shoichiro; Shinohara, Shunjiro [Kyushu Univ., Interdisciplinary Graduate School of Engineering Sciences, Fukuoka (Japan)

    2001-07-01

    A large density profile modification was successfully obtained by voltage biasing to electrodes inserted in a RF (radio frequency) produced, magnetized plasma, and formation of strong shear of azimuthal plasma rotation velocity in a supersonic regime was found. For the case of biasing to an electrode near the central plasma region, two types of density transitions were observed in the outer plasma region: one was an oscillatory transition between two states, and the other was a transition from high to low density states with a large reduction of density fluctuations. (author)

  18. Asymmetry of edge plasma turbulence in biasing experiments on tokamak TF-2

    International Nuclear Information System (INIS)

    Budaev, V.P.

    1994-01-01

    It was observed in tokamaks the suppression of edge turbulence causes by setting a radial electric field at the plasma edge. The poloidal plasma rotation governed by this electric field is likely to result in changes in edge convention and poloidal asymmetry, however there is no experimental evidence about that of the experimental database concerning the biasing and conditions of edge plasma electrostatic turbulence excitation is not still complete. Also a relation between macroscopic convection and small-scale electrostatic turbulence have not yet revealed both in biasing and non biasing plasmas. In this paper results from biasing experiments carried on on ohmically heated tokamak TF-2 are presented. Changes in both equilibrium and fluctuated edge plasma parameters also convection and turbulence driven particle flux were demonstrated in probe measurements with biasing of electrode immersed within Last Closed Flux Surface (LCFS). Poloidal edge plasma structure and charge in asymmetry have demonstrated in the biasing experiments. (author). 6 refs, 4 figs

  19. Social influence bias: a randomized experiment.

    Science.gov (United States)

    Muchnik, Lev; Aral, Sinan; Taylor, Sean J

    2013-08-09

    Our society is increasingly relying on the digitized, aggregated opinions of others to make decisions. We therefore designed and analyzed a large-scale randomized experiment on a social news aggregation Web site to investigate whether knowledge of such aggregates distorts decision-making. Prior ratings created significant bias in individual rating behavior, and positive and negative social influences created asymmetric herding effects. Whereas negative social influence inspired users to correct manipulated ratings, positive social influence increased the likelihood of positive ratings by 32% and created accumulating positive herding that increased final ratings by 25% on average. This positive herding was topic-dependent and affected by whether individuals were viewing the opinions of friends or enemies. A mixture of changing opinion and greater turnout under both manipulations together with a natural tendency to up-vote on the site combined to create the herding effects. Such findings will help interpret collective judgment accurately and avoid social influence bias in collective intelligence in the future.

  20. “Virtual IED sensor” at an rf-biased electrode in low-pressure plasma

    Energy Technology Data Exchange (ETDEWEB)

    Bogdanova, M. A.; Zyryanov, S. M. [Skobeltsyn Institute of Nuclear Physics, Moscow State University, SINP MSU, Moscow (Russian Federation); Faculty of Physics, Moscow State University, MSU, Moscow (Russian Federation); Lopaev, D. V.; Rakhimov, A. T. [Skobeltsyn Institute of Nuclear Physics, Moscow State University, SINP MSU, Moscow (Russian Federation)

    2016-07-15

    Energy distribution and the flux of the ions coming on a surface are considered as the key-parameters in anisotropic plasma etching. Since direct ion energy distribution (IED) measurements at the treated surface during plasma processing are often hardly possible, there is an opportunity for virtual ones. This work is devoted to the possibility of such indirect IED and ion flux measurements at an rf-biased electrode in low-pressure rf plasma by using a “virtual IED sensor” which represents “in-situ” IED calculations on the absolute scale in accordance with a plasma sheath model containing a set of measurable external parameters. The “virtual IED sensor” should also involve some external calibration procedure. Applicability and accuracy of the “virtual IED sensor” are validated for a dual-frequency reactive ion etching (RIE) inductively coupled plasma (ICP) reactor with a capacitively coupled rf-biased electrode. The validation is carried out for heavy (Ar) and light (H{sub 2}) gases under different discharge conditions (different ICP powers, rf-bias frequencies, and voltages). An EQP mass-spectrometer and an rf-compensated Langmuir probe (LP) are used to characterize plasma, while an rf-compensated retarded field energy analyzer (RFEA) is applied to measure IED and ion flux at the rf-biased electrode. Besides, the pulsed selfbias method is used as an external calibration procedure for ion flux estimating at the rf-biased electrode. It is shown that pulsed selfbias method allows calibrating the IED absolute scale quite accurately. It is also shown that the “virtual IED sensor” based on the simplest collisionless sheath model allows reproducing well enough the experimental IEDs at the pressures when the sheath thickness s is less than the ion mean free path λ{sub i} (s < λ{sub i}). At higher pressure (when s > λ{sub i}), the difference between calculated and experimental IEDs due to ion collisions in the sheath is observed in the low

  1. Reducing hypothetical bias in choice experiments

    DEFF Research Database (Denmark)

    Ladenburg, Jacob; Olsen, Søren Bøye; Nielsen, Rasmus Christian Fejer

    eliminate some of the hypothetical bias. The present paper tests an addition to Cheap Talk, an Opt-Out Reminder. The Opt-Out Reminder is an objective short script presented prior to the choice sets, prompting the respondent to choose the opt-out alternative, if he/she finds the proposed policy generated...... alternatives in a choice set too expensive. The results suggest that adding an Opt-Out Reminder to Cheap Talk can in fact reduce hypothetical bias even further and reduces some of the ineffectiveness of CT in relation to the survey bid range and experienced respondents....

  2. Atomic-Scale Simulation of Electrochemical Processes at Electrode/Water Interfaces under Referenced Bias Potential.

    Science.gov (United States)

    Bouzid, Assil; Pasquarello, Alfredo

    2018-04-19

    Based on constant Fermi-level molecular dynamics and a proper alignment scheme, we perform simulations of the Pt(111)/water interface under variable bias potential referenced to the standard hydrogen electrode (SHE). Our scheme yields a potential of zero charge μ pzc of ∼0.22 eV relative to the SHE and a double layer capacitance C dl of ≃19 μF cm -2 , in excellent agreement with experimental measurements. In addition, we study the structural reorganization of the electrical double layer for bias potentials ranging from -0.92 eV to +0.44 eV and find that O down configurations, which are dominant at potentials above the pzc, reorient to favor H down configurations as the measured potential becomes negative. Our modeling scheme allows one to not only access atomic-scale processes at metal/water interfaces, but also to quantitatively estimate macroscopic electrochemical quantities.

  3. Limiter biasing experiments on the tokamak ISTTOK

    Czech Academy of Sciences Publication Activity Database

    Silva, C.; Nedzelskiy, I.; Figueiredo, H.; Cabral, J. A. C.; Varandas, C. A. F.; Stöckel, Jan

    2003-01-01

    Roč. 53, č. 10 (2003), s. 937-944 ISSN 0011-4626. [Workshop "Electric Fields Structures and Relaxation in Edge Plasmas"/6th./. St. Petersburg, 13.06.2003-14.06.2003] Institutional research plan: CEZ:AV0Z2043910 Keywords : biasing, edge plasma, particle confinement Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 0.263, year: 2003

  4. Disruption avoidance in the SINP-Tokamak by means of electrode-biasing at the plasma edge

    Energy Technology Data Exchange (ETDEWEB)

    Basu, Debjyoti [Saha Institute of Nuclear Physics, 1/AF-Bidhannagar, Kolkata 700064, WB (India); Instituto de Ciencias Nucleares-UNAM, Mexico D.F. 04510 (Mexico); Pal, Rabindranath [Saha Institute of Nuclear Physics, 1/AF-Bidhannagar, Kolkata 700064, WB (India); Martinell, Julio J. [Instituto de Ciencias Nucleares-UNAM, Mexico D.F. 04510 (Mexico); Ghosh, Joydeep; Chattopadhyay, Prabal K. [Institute for Plasma Research, Gandhinagar (India)

    2013-05-15

    Control of plasma disruption by a biased edge electrode is reported in SINP-Tokamak. The features that characterize a plasma disruption are reduced with increasing bias potential. The disruption can be completely suppressed with the concomitant stabilization of observed MHD modes that are allegedly precursors of the disruption. An m = 3/n = 1 tearing mode, which apparently causes disruption can be stabilized when a negative biasing potential is applied near the edge. These changes in the disruptive behavior with edge biasing are hypothesized to be due to changes in the current density profile.

  5. Disruption avoidance in the SINP-Tokamak by means of electrode-biasing at the plasma edge

    International Nuclear Information System (INIS)

    Basu, Debjyoti; Pal, Rabindranath; Martinell, Julio J.; Ghosh, Joydeep; Chattopadhyay, Prabal K.

    2013-01-01

    Control of plasma disruption by a biased edge electrode is reported in SINP-Tokamak. The features that characterize a plasma disruption are reduced with increasing bias potential. The disruption can be completely suppressed with the concomitant stabilization of observed MHD modes that are allegedly precursors of the disruption. An m = 3/n = 1 tearing mode, which apparently causes disruption can be stabilized when a negative biasing potential is applied near the edge. These changes in the disruptive behavior with edge biasing are hypothesized to be due to changes in the current density profile

  6. Target selection biases from recent experience transfer across effectors.

    Science.gov (United States)

    Moher, Jeff; Song, Joo-Hyun

    2016-02-01

    Target selection is often biased by an observer's recent experiences. However, not much is known about whether these selection biases influence behavior across different effectors. For example, does looking at a red object make it easier to subsequently reach towards another red object? In the current study, we asked observers to find the uniquely colored target object on each trial. Randomly intermixed pre-trial cues indicated the mode of action: either an eye movement or a visually guided reach movement to the target. In Experiment 1, we found that priming of popout, reflected in faster responses following repetition of the target color on consecutive trials, occurred regardless of whether the effector was repeated from the previous trial or not. In Experiment 2, we examined whether an inhibitory selection bias away from a feature could transfer across effectors. While priming of popout reflects both enhancement of the repeated target features and suppression of the repeated distractor features, the distractor previewing effect isolates a purely inhibitory component of target selection in which a previewed color is presented in a homogenous display and subsequently inhibited. Much like priming of popout, intertrial suppression biases in the distractor previewing effect transferred across effectors. Together, these results suggest that biases for target selection driven by recent trial history transfer across effectors. This indicates that representations in memory that bias attention towards or away from specific features are largely independent from their associated actions.

  7. Electrode Conduction Processes Segmented Electrode-Insulator Ratio Effects in MHD Power Generation Experiments

    Energy Technology Data Exchange (ETDEWEB)

    Pain, H. J.; Fearn, D. G.; Distefano, E. [Imperial College. London (United Kingdom)

    1966-10-15

    (a) Electrode conduction processes have been investigated using a plasma produced in an electromagnetic shock tube operating with argon at 70 {mu}mHg pressure. Complete voltage-current characteristics were obtained by the variation of load and applied voltage. These indicated the existence of two conduction regimes with a complex transition region. In the first regime the current, controlled by ion mobility, rose linearly with voltage to saturate between 10 mA and 1 A depending on conditions. Electrode contamination was significant. The second regime involved large currents controlled by electron mobility and emission from the cathode. The current again increased linearly with voltage and reached 200 A. Observation of induced voltages in transverse magnetic fields and of plasma deceleration in non-uniform fields showed that in the electromagnetic shock tube the plasma was heated predominantly by the driver discharge. Its conductivity was calculated using properties measured by a Langmuir double probe. In both regimes the plasma conductivity was also found from the gradient of the voltage current characteristics using experimental electric field fringing factors and the experimental values were compared with theory. (b) Larger-scale experiments used a combustion-driven shock tube where argon plasma flow, magnetic field and induced current flow were mutually orthogonal. The supersonic flow velocity and thermodynamic parameters of the plasma were accurately known. The electrode channel consisted of a segmented system of 12 electrode pairs with an electrode insulator ratio ranging from 1 to 21, with electrode plus insulator length remaining constant, and with maximum Hall parameter values of unity. Different electrode load combinations (Faraday and Hall generators) have been studied in measuring the power generated and the flow of longitudinal currents between adjacent electrodes. A maximum power of 0,8 MW was obtained, the power output decreasing inversely with the

  8. Electrode Conduction Processes Segmented Electrode-Insulator Ratio Effects in MHD Power Generation Experiments

    International Nuclear Information System (INIS)

    Pain, H.J.; Fearn, D.G.; Distefano, E.

    1966-01-01

    (a) Electrode conduction processes have been investigated using a plasma produced in an electromagnetic shock tube operating with argon at 70 μmHg pressure. Complete voltage-current characteristics were obtained by the variation of load and applied voltage. These indicated the existence of two conduction regimes with a complex transition region. In the first regime the current, controlled by ion mobility, rose linearly with voltage to saturate between 10 mA and 1 A depending on conditions. Electrode contamination was significant. The second regime involved large currents controlled by electron mobility and emission from the cathode. The current again increased linearly with voltage and reached 200 A. Observation of induced voltages in transverse magnetic fields and of plasma deceleration in non-uniform fields showed that in the electromagnetic shock tube the plasma was heated predominantly by the driver discharge. Its conductivity was calculated using properties measured by a Langmuir double probe. In both regimes the plasma conductivity was also found from the gradient of the voltage current characteristics using experimental electric field fringing factors and the experimental values were compared with theory. (b) Larger-scale experiments used a combustion-driven shock tube where argon plasma flow, magnetic field and induced current flow were mutually orthogonal. The supersonic flow velocity and thermodynamic parameters of the plasma were accurately known. The electrode channel consisted of a segmented system of 12 electrode pairs with an electrode insulator ratio ranging from 1 to 21, with electrode plus insulator length remaining constant, and with maximum Hall parameter values of unity. Different electrode load combinations (Faraday and Hall generators) have been studied in measuring the power generated and the flow of longitudinal currents between adjacent electrodes. A maximum power of 0,8 MW was obtained, the power output decreasing inversely with the

  9. Bias induced transition from an ohmic to a non-ohmic interface in supramolecular tunneling junctions with Ga2O3/EGaIn top electrodes.

    Science.gov (United States)

    Wimbush, Kim S; Fratila, Raluca M; Wang, Dandan; Qi, Dongchen; Liang, Cao; Yuan, Li; Yakovlev, Nikolai; Loh, Kian Ping; Reinhoudt, David N; Velders, Aldrik H; Nijhuis, Christian A

    2014-10-07

    This study describes that the current rectification ratio, R ≡ |J|(-2.0 V)/|J|(+2.0 V) for supramolecular tunneling junctions with a top-electrode of eutectic gallium indium (EGaIn) that contains a conductive thin (0.7 nm) supporting outer oxide layer (Ga2O3), increases by up to four orders of magnitude under an applied bias of >+1.0 V up to +2.5 V; these junctions did not change their electrical characteristics when biased in the voltage range of ±1.0 V. The increase in R is caused by the presence of water and ions in the supramolecular assemblies which react with the Ga2O3/EGaIn layer and increase the thickness of the Ga2O3 layer. This increase in the oxide thickness from 0.7 nm to ∼2.0 nm changed the nature of the monolayer-top-electrode contact from an ohmic to a non-ohmic contact. These results unambiguously expose the experimental conditions that allow for a safe bias window of ±1.0 V (the range of biases studies of charge transport using this technique are normally conducted) to investigate molecular effects in molecular electronic junctions with Ga2O3/EGaIn top-electrodes where electrochemical reactions are not significant. Our findings also show that the interpretation of data in studies involving applied biases of >1.0 V may be complicated by electrochemical side reactions which can be recognized by changes of the electrical characteristics as a function voltage cycling or in current retention experiments.

  10. Effects of the molecule-electrode interface on the low-bias conductance of Cu-H2-Cu single-molecule junctions.

    Science.gov (United States)

    Jiang, Zhuoling; Wang, Hao; Shen, Ziyong; Sanvito, Stefano; Hou, Shimin

    2016-07-28

    The atomic structure and electronic transport properties of a single hydrogen molecule connected to both symmetric and asymmetric Cu electrodes are investigated by using the non-equilibrium Green's function formalism combined with the density functional theory. Our calculations show that in symmetric Cu-H2-Cu junctions, the low-bias conductance drops rapidly upon stretching, while asymmetric ones present a low-bias conductance spanning the 0.2-0.3 G0 interval for a wide range of electrode separations. This is in good agreement with experiments on Cu atomic contacts in a hydrogen environment. Furthermore, the distribution of the calculated vibrational energies of the two hydrogen atoms in the asymmetric Cu-H2-Cu junction is also consistent with experiments. These findings provide clear evidence for the formation of asymmetric Cu-H2-Cu molecular junctions in breaking Cu atomic contacts in the presence of hydrogen and are also helpful for the design of molecular devices with Cu electrodes.

  11. Can decision biases improve insurance outcomes? An experiment on status quo bias in health insurance choice.

    Science.gov (United States)

    Krieger, Miriam; Felder, Stefan

    2013-06-19

    Rather than conforming to the assumption of perfect rationality in neoclassical economic theory, decision behavior has been shown to display a host of systematic biases. Properly understood, these patterns can be instrumentalized to improve outcomes in the public realm. We conducted a laboratory experiment to study whether decisions over health insurance policies are subject to status quo bias and, if so, whether experience mitigates this framing effect. Choices in two treatment groups with status quo defaults are compared to choices in a neutrally framed control group. A two-step design features sorting of subjects into the groups, allowing us to control for selection effects due to risk preferences. The results confirm the presence of a status quo bias in consumer choices over health insurance policies. However, this effect of the default framing does not persist as subjects repeat this decision in later periods of the experiment. Our results have implications for health care policy, for example suggesting that the use of non-binding defaults in health insurance can facilitate the spread of co-insurance policies and thereby help contain health care expenditure.

  12. Can Decision Biases Improve Insurance Outcomes? An Experiment on Status Quo Bias in Health Insurance Choice

    Science.gov (United States)

    Krieger, Miriam; Felder, Stefan

    2013-01-01

    Rather than conforming to the assumption of perfect rationality in neoclassical economic theory, decision behavior has been shown to display a host of systematic biases. Properly understood, these patterns can be instrumentalized to improve outcomes in the public realm. We conducted a laboratory experiment to study whether decisions over health insurance policies are subject to status quo bias and, if so, whether experience mitigates this framing effect. Choices in two treatment groups with status quo defaults are compared to choices in a neutrally framed control group. A two-step design features sorting of subjects into the groups, allowing us to control for selection effects due to risk preferences. The results confirm the presence of a status quo bias in consumer choices over health insurance policies. However, this effect of the default framing does not persist as subjects repeat this decision in later periods of the experiment. Our results have implications for health care policy, for example suggesting that the use of non-binding defaults in health insurance can facilitate the spread of co-insurance policies and thereby help contain health care expenditure. PMID:23783222

  13. Can Decision Biases Improve Insurance Outcomes? An Experiment on Status Quo Bias in Health Insurance Choice

    Directory of Open Access Journals (Sweden)

    Stefan Felder

    2013-06-01

    Full Text Available Rather than conforming to the assumption of perfect rationality in neoclassical economic theory, decision behavior has been shown to display a host of systematic biases. Properly understood, these patterns can be instrumentalized to improve outcomes in the public realm. We conducted a laboratory experiment to study whether decisions over health insurance policies are subject to status quo bias and, if so, whether experience mitigates this framing effect. Choices in two treatment groups with status quo defaults are compared to choices in a neutrally framed control group. A two-step design features sorting of subjects into the groups, allowing us to control for selection effects due to risk preferences. The results confirm the presence of a status quo bias in consumer choices over health insurance policies. However, this effect of the default framing does not persist as subjects repeat this decision in later periods of the experiment. Our results have implications for health care policy, for example suggesting that the use of non-binding defaults in health insurance can facilitate the spread of co-insurance policies and thereby help contain health care expenditure.

  14. ALT-II toroidal belt limiter biasing experiments on TEXTOR

    International Nuclear Information System (INIS)

    Doerner, R.; Boedo, J.A.; Gray, D.S.

    1991-01-01

    Edge electric fields have been related to H-mode-like behaviour. The experiments reported here are an attempt to control the SOL profiles by electrostatic biasing of the full toroidal-belt limiter ALT-II. The specific goals are: influencing the edge particle flows, particle removal, power deposition and the global confinement. The ALT-II pump limiter is a full toroidal belt located at 45 o below the outer midplane and consisting of eight graphite covered blades which can be independently biased. Particle scoops located behind the limiter neutralize and direct the incoming plasma into the pumping ducts. (author) 5 refs., 3 figs

  15. Hispanic nurses' experiences of bias in the workplace.

    Science.gov (United States)

    Moceri, Joane T

    2014-01-01

    The continuing issue of health inequity for Hispanics highlights the importance of retaining Hispanic nurses in the workplace. This article describes the use of short answers such as "Describe the bias you experienced" and "If a patient refused care, what was the reason given?" to increase understandings about bias through the descriptions of Hispanic nurses. In this study, bias was defined as those implicit negative stereotypes and attitudes that negatively affect judgments about, evaluations of, and actions toward others. For this qualitative component of a descriptive study employing both qualitative and quantitative methods, 111 Hispanic nurses responded to open-ended questions about experiences of bias that were included with a survey tool and demographic questionnaire. Three themes emerged: being overlooked and undervalued, having to prove competency, and living with "only-ness." Respect was an overarching concept. The written descriptions of bias provided depth and understanding to the quantitative findings. Nurse leaders are well positioned to develop and implement strategies to more effectively support Hispanic nurses and to promote nonbiased interactions in the workplace. Retaining Hispanic nurses is a vital component to address issues of health inequity for Hispanic patients.

  16. Emissive limiter bias experiment for improved confinement of tokamaks

    International Nuclear Information System (INIS)

    Choe, W.; Ono, M.; Darrow, D.S.; Pribyl, P.A.; Liberati, J.R.; Taylor, R.J.

    1992-01-01

    Experiments have been performed in Ohmic discharges of the UCLA CCT tokamak with a LaB 6 biased limiter, capable of emitting energetic electrons as a technique to improve confinement in tokamaks. To study the effects of emitted electrons, the limiter position, bias voltage, and plasma position were varied. The results have shown that the plasma positioning with respect to the emissive limiter plays an important role in obtaining H-mode plasmas. The emissive cathode must be located close to the last closed flux surface in order to charge up the plasma. As the cathode is moved closer to the wall, the positioning of the plasma becomes more critical since the plasma can easily detach from the cathode and reattach to the wall, resulting in the termination of H-mode. The emissive capability appears to be important for operating at lower bias voltage and reducing impurity levels in the plasma. With a heated cathode, transition to H-mode was observed for V bias ≤ 50 V and I inj ≥ 30 A. At a lower cathode heater current, a higher bias voltage is required for the transition. Moreover, with a lower cathode heater current, the time delay for inducing H-mode becomes longer, which can be attributed to the required time for the self-heating of the cathode to reach the emissive temperature. From this result, we conclude that the capacity for emission can significantly improve the performance of limiter biasing for inducing H-mode transition. With L-mode plasmas, the injection current flowing out of the cathode was generally higher than 100 A

  17. Multicultural experiences reduce intergroup bias through epistemic unfreezing.

    Science.gov (United States)

    Tadmor, Carmit T; Hong, Ying-Yi; Chao, Melody M; Wiruchnipawan, Fon; Wang, Wei

    2012-11-01

    In 6 studies, we systematically explored for the 1st time the ameliorative effects of multicultural experience on intergroup bias and investigated the role of epistemic unfreezing as the motivational mechanism underlying these effects. We found that multicultural exposure led to a reduction in stereotype endorsement (Studies 1, 4, and 6), symbolic racism (Study 5), and discriminatory hiring decisions (Study 2). We further demonstrated that experimental exposure to multicultural experience caused a reduction in need for cognitive closure (NFCC; Studies 3 and 6) and that the ameliorative effects of multiculturalism experience on intergroup bias were fully mediated by lower levels of NFCC (Studies 4, 5, and 6). The beneficial effects of multiculturalism were found regardless of the targeted stereotype group (African Americans, Ethiopians, homosexuals, and native Israelis), regardless of whether multicultural experience was measured or manipulated, and regardless of the population sampled (Caucasian Americans or native Israelis), demonstrating the robustness of this phenomenon. Overall, these results demonstrate that multicultural experience plays a critical role in increasing social tolerance through its relationship to motivated cognitive processes.

  18. Observation of self-organized criticality (SOC) behavior during edge biasing experiment on TEXTOR

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Y.H.; Jachmich, S.; Weynants, R.R. [Ecole Royale Militaire/Koninklijke Militaire School, Laboratory for Plasma Physics, Euratom-Belgian State Association, Brussels, Belgium, Partner in the Trilateral Euregio Cluster (Belgium)

    2004-07-01

    The self-organized criticality (SOC) behavior of the edge plasma transport has been investigated using the fluctuation data measured in the plasma edge and the scrape-off layer of TEXTOR tokamak before and during the edge electrode biasing experiments. In the 'non-shear' discharge phase before biasing, both the potential and density fluctuations clearly exhibit some of the characteristics associated with SOC: (1) existence of f{sup -1} power-law dependence in the frequency spectrum, (2) slowly decaying long tails in the autocorrelation function, (3) values of Hurst parameters larger than 0.5 at all the detected radial locations, (4) non-Gaussian probability density function of fluctuations and (5) radial propagation of avalanche-like events in the edge plasma area. During the biasing phase, with the generation of an edge radial electric field E{sub r} and hence a sheared E{sub r} x B flow, the local turbulence is found to be well de-correlated by the E{sub r} x B velocity shear, consistent with theoretical predictions. Nevertheless, it is concomitantly found that the Hurst parameters are substantially enhanced in the negative flow shear region and in the scrape-off layer as well, which is contrary to theoretical expectation. Implication of these observations to our understanding of plasma transport mechanisms is discussed. (authors)

  19. Bias-polarity-dependent UV/visible transferable electroluminescence from ZnO nanorod array LED with graphene oxide electrode supporting layer

    Science.gov (United States)

    Liu, Weizhen; Wang, Wei; Xu, Haiyang; Li, Xinghua; Yang, Liu; Ma, Jiangang; Liu, Yichun

    2015-09-01

    A simple top electrode preparation process, employing continuous graphene oxide films as electrode supporting layers, was adopted to fabricate a ZnO nanorod array/p-GaN heterojunction LED. The achieved LED demonstrated different electroluminescence behaviors under forward and reverse biases: a yellow-red emission band was observed under forward bias, whereas a blue-UV emission peak was obtained under reverse bias. Electroluminescence spectra under different currents and temperatures, as well as heterojunction energy-band alignments, reveal that the yellow-red emission under forward bias originates from recombinations related to heterointerface defects, whereas the blue-UV electroluminescence under reverse bias is ascribed to transitions from near-band-edge and Mg-acceptor levels in p-GaN.

  20. Profile Control by Biased Electrodes in Large Diameter RF Produced Pl asma

    Science.gov (United States)

    Shinohara, Shunjiro; Matsuoka, Norikazu; Yoshinaka, Toshiro

    1998-10-01

    Control of the plasma profile has been carried out, using the voltage biasing method in the large diameter (45 cm) RF (radio frequency) produced plasma in the presence of the uniform magnetic field (less than 1200 G). Under the low filling pressure condition of 0.16 mTorr, changing the biasing voltages to the three individual end plates with concentric circular ring shapes, the radial electron density (about 10^10 cm-3) profile could be changed from the hollow to the peaked one. On the contrary, the nearly flat electron temperature (several eV) profile did not change appreciably. The azimuthal rotation velocity measured by the Mach probe, i.e. directional probe, showed the different radial profiles (but nearly uniform along the axis) depending on the biasing voltage. This velocity became slower with the low magnetic field (less than 200 G) or in the higher pressure regime up to 20 mTorr with the higher electron density. The experimental results by other biasing methods will also be presented.

  1. Effect of Particle Size on Electrode Potential and Thermodynamics of Nanoparticles Electrode in Theory and Experiment

    International Nuclear Information System (INIS)

    Yunfeng, Yang; Yongqiang, Xue; Zixiang, Cui; Miaozhi, Zhao

    2014-01-01

    The particle size of electrode materials has a significant influence on the standard electrode potential and the thermodynamic properties of electrode reactions. In this paper, the size-dependent electrochemical thermodynamics has been theoretically investigated and successfully deduced electrochemical thermodynamics equations for nanoparticles electrode. At the same time, the electrode potential and thermodynamical properties of Ag 2 O/Ag nanoparticles electrode constructed by the solid and spherical Ag 2 O nanoparticles with different sizes further testified that the particle size of nanoparticles has a significant effect on electrochemical thermodynamics. The results show that the electrode potential depends on that of the smallest nanoparticle in a nanoparticles electrode which consisted of different particle sizes of nano-Ag 2 O. When the size of Ag 2 O nanoparticles reduces, the standard electrode potentials and the equilibrium constants of the corresponding electrode reactions increase, and the temperature coefficient, the mole Gibbs energy change, the mole enthalpy change and the mole entropy change decrease. Moreover, these physical quantities are all linearly related with the reciprocal of average particle size (r > 10 nm). The experimental regularities coincide with the theoretical equations

  2. Monte Carlo learning/biasing experiment with intelligent random numbers

    International Nuclear Information System (INIS)

    Booth, T.E.

    1985-01-01

    A Monte Carlo learning and biasing technique is described that does its learning and biasing in the random number space rather than the physical phase-space. The technique is probably applicable to all linear Monte Carlo problems, but no proof is provided here. Instead, the technique is illustrated with a simple Monte Carlo transport problem. Problems encountered, problems solved, and speculations about future progress are discussed. 12 refs

  3. Collisional effects on ion energy and angular distributions incident on RF-biased electrodes

    International Nuclear Information System (INIS)

    Qiu Huatan; Wang Younian; Ma Tengcai

    2002-01-01

    Taking into account elastic collisions and charge-exchange collisions between ions and neutral particles, the authors established a self-consistent model describing the dynamics of radio-frequency (RF) sheath driven by a sinusoidal current source, and also, using the Monte-Carlo Method, simulated energy and angle distributions of ions bombarding on RF-biased substrates. It has been shown from numerical results that as increasing the discharge pressure, bimodal-peaks distributions for the ion energy become gradually a single-peak distribution, and low-energy ions increase. The authors also found that the angle distribution of ions is narrow and almost do not change with increasing the discharge pressure

  4. Rotating ring-ring electrode theory and experiment

    NARCIS (Netherlands)

    Kuiken, H.K.; Bakkers, E.P.A.M.; Ligthart, H.; Kellyb, J.J.

    2000-01-01

    A model is presented for the rotating ring-ring electrode. Although the electrode is defined by four characteristic lengths, it is shown that the collection efficiency depends on only two dimensionless parameters. A simple relationship between these and the corresponding parameters for the rotating

  5. The Rotating Ring-Ring Electrode. Theory and Experiment

    NARCIS (Netherlands)

    Kuiken, H.K.; Bakkers, E.P.A.M.; Ligthart, H.; Kelly, J.J.

    2000-01-01

    A model is presented for the rotating ring-ring electrode. Although the electrode is defined by four characteristic lengths, it is shown that the collection efficiency depends on only two dimensionless parameters. A simple relationship between these and the corresponding parameters for the rotating

  6. EXPERIMENT WITH A BIASED DISK AT THE KVI ECRIS

    NARCIS (Netherlands)

    GAMMINO, S; SIJBRING, J; DRENTJE, AG

    Some measurements have been done on the source ECRIS 1 at K.V.I., showing the beneficial effect to the output currents when a biased disk is positioned in the first stage, as reported by the Grenoble ECRIS group. The increase is in the order of 40% and it can be explained by the enrichment of the

  7. Differential effects of weight bias experiences and internalization on exercise among women with overweight and obesity.

    Science.gov (United States)

    Pearl, Rebecca L; Puhl, Rebecca M; Dovidio, John F

    2015-12-01

    This study investigated the effects of experiences with weight stigma and weight bias internalization on exercise. An online sample of 177 women with overweight and obesity (M(age) = 35.48 years, M(BMI) = 32.81) completed questionnaires assessing exercise behavior, self-efficacy, and motivation; experiences of weight stigmatization; weight bias internalization; and weight-stigmatizing attitudes toward others. Weight stigma experiences positively correlated with exercise behavior, but weight bias internalization was negatively associated with all exercise variables. Weight bias internalization was a partial mediator between weight stigma experiences and exercise behavior. The distinct effects of experiencing versus internalizing weight bias carry implications for clinical practice and public health. © The Author(s) 2014.

  8. Advanced Biasing Experiments on the C-2 Field-Reversed Configuration Device

    Science.gov (United States)

    Thompson, Matthew; Korepanov, Sergey; Garate, Eusebio; Yang, Xiaokang; Gota, Hiroshi; Douglass, Jon; Allfrey, Ian; Valentine, Travis; Uchizono, Nolan; TAE Team

    2014-10-01

    The C-2 experiment seeks to study the evolution, heating and sustainment effects of neutral beam injection on field-reversed configuration (FRC) plasmas. Recently, substantial improvements in plasma performance were achieved through the application of edge biasing with coaxial plasma guns located in the divertors. Edge biasing provides rotation control that reduces instabilities and E × B shear that improves confinement. Typically, the plasma gun arcs are run at ~ 10 MW for the entire shot duration (~ 5 ms), which will become unsustainable as the plasma duration increases. We have conducted several advanced biasing experiments with reduced-average-power plasma gun operating modes and alternative biasing cathodes in an effort to develop an effective biasing scenario applicable to steady state FRC plasmas. Early results show that several techniques can potentially provide effective, long-duration edge biasing.

  9. The role of experience on techno-entrepreneurs’ decision making biases

    Directory of Open Access Journals (Sweden)

    Pouria Nouri

    2012-10-01

    Full Text Available Entrepreneurs are the driving force behind the prospect and growth of the societies. Sound and wise decisions pave the way for them to carry out these highly important functions. Entrepreneurs are to discover and exploit opportunities. Therefore, they must gather sufficient and pertinent information. Entrepreneurs, like most human beings face complex and ambiguous decision-making situations, not to mention their lack of time and source to gather and process the data. Under these circumstances, entrepreneurs are prone making biases decisions. There are many reasons identified for this entrepreneurial decision making biases, such as the high cost of rational decision making, limitations in information processing, differences in their styles and procedures, or information overload, environmental complexity, environmental uncertainty. These biases are neither totally harmful nor completely useful and have to be seen as natural human characteristics. What makes entrepreneurial decision-making biases important is their effects on the decisions and thus the outcome of the enterprises. Entrepreneurial decision-making biases, deliberate or unintentional can seal the fate of the enterprises, therefore studying them meticulously is crucial. Literature has shown that experience could be an effective factor in decision-making biases. In this paper, we try to find out the impact of experience in Iranian high tech entrepreneurs’ major decision-making biases by a qualitative approach. Finally, it was concluded that experience is influential in shaping overconfidence bias.

  10. Experiment study on four button electrode used to monitor position of high current electron-beam

    International Nuclear Information System (INIS)

    Xu Tiezheng; Wang Huacen; Xie Yutong; Zhang Wenwei

    2004-01-01

    The button electrode is one that widely used in high energy accelerators, such as storage ring, and the button electrode has many merit like high accuracy, high resolution, resisting magnetic field, simple machinery, without magnetic core and low cost, etc. It's helpful that the button electrode is used as the beam position monitor in the linear induction accelerator. The experimental facilities have been designed and set up and it can simulate the beam of linear induction accelerator. The button electrode beam position monitor experiment have been done on the experimental facilities. The result of the experiment prove that the button electrode has an accuracy of 0.5 mm, and can reflect the wave of electron-beam accurately

  11. Studying Gender Bias in Physics Grading: The Role of Teaching Experience and Country

    Science.gov (United States)

    Hofer, Sarah I.

    2015-01-01

    The existence of gender-STEM (science, technology, engineering, and mathematics) stereotypes has been repeatedly documented. This article examines physics teachers' gender bias in grading and the influence of teaching experience in Switzerland, Austria, and Germany. In a 2?×?2 between-subjects design, with years of teaching experience included as…

  12. Can a Repeated Opt-Out Reminder mitigate hypothetical bias in discrete choice experiments?

    DEFF Research Database (Denmark)

    Alemu, Mohammed Hussen; Olsen, Søren Bøye

    2018-01-01

    In this paper, we test whether a Repeated Opt-Out Reminder (ROOR) can mitigate hypothetical bias in stated discrete choice experiments (DCE). The data originate from a field experiment concerning consumer preferences for a novel food product made from cricket flour. Utilising a between...

  13. Perceptual expertise: can sensorimotor experience change holistic processing and left-side bias?

    Science.gov (United States)

    Tso, Ricky Van-yip; Au, Terry Kit-fong; Hsiao, Janet Hui-wen

    2014-09-01

    Holistic processing and left-side bias are both behavioral markers of expert face recognition. By contrast, expert recognition of characters in Chinese orthography involves left-side bias but reduced holistic processing, although faces and Chinese characters share many visual properties. Here, we examined whether this reduction in holistic processing of Chinese characters can be better explained by writing experience than by reading experience. Compared with Chinese nonreaders, Chinese readers who had limited writing experience showed increased holistic processing, whereas Chinese readers who could write characters fluently showed reduced holistic processing. This result suggests that writing and sensorimotor experience can modulate holistic-processing effects and that the reduced holistic processing observed in expert Chinese readers may depend mostly on writing experience. However, both expert writers and writers with limited experience showed similarly stronger left-side bias than novices did in processing mirror-symmetric Chinese characters; left-side bias may therefore be a robust expertise marker for object recognition that is uninfluenced by sensorimotor experience. © The Author(s) 2014.

  14. No Girls Allowed: Women in Male-Dominated Majors Experience Increased Gender Harassment and Bias.

    Science.gov (United States)

    Dresden, Brooke E; Dresden, Alexander Y; Ridge, Robert D; Yamawaki, Niwako

    2018-06-01

    The prevalence of gender harassment in male-dominated workforces has been well established, but little is known regarding the experiences of women in male-dominated majors within academia. The current study examines the experiences and gender-related biases of 146 male and female students in male-dominated (MD) and gender-equivalent (GE) majors. This study hypothesizes that men from MD majors, as opposed to GE majors, will exhibit more explicit and implicit bias regarding women in positions of power and authority, resulting in a higher prevalence of gender harassment towards women in MD majors. Results showed that there was no significant difference in self-reported explicit bias against women in positions of power and authority between men from MD and GE majors, but there was significantly more implicit bias among men from MD majors as opposed to GE majors. Additionally, women from MD majors experienced significantly more gender harassment than women from GE majors. Implications of these findings and suggestions to assist those working in education to combat these biases and instances of harassment are discussed.

  15. Using respondent uncertainty to mitigate hypothetical bias in a stated choice experiment

    Science.gov (United States)

    Richard C. Ready; Patricia A. Champ; Jennifer L. Lawton

    2010-01-01

    In a choice experiment study, willingness to pay for a public good estimated from hypothetical choices was three times as large as willingness to pay estimated from choices requiring actual payment. This hypothetical bias was related to the stated level of certainty of respondents. We develop protocols to measure respondent certainty in the context of a choice...

  16. Can a Repeated Opt-Out Reminder remove hypothetical bias in discrete choice experiments?

    DEFF Research Database (Denmark)

    Alemu, Mohammed Hussen; Olsen, Søren Bøye

    hypothetical bias in stated DCE. The data originates from a field experiment concerning consumer preferences for a novel food product made from cricket flour. Utilizing a between-subject design with three treatments, we find significantly higher marginal willingness to pay values in hypothetical than...

  17. High density plasma productions by hydrogen storage electrode in the Tohoku University Heliac

    International Nuclear Information System (INIS)

    Utoh, H.; Takahashi, H.; Tanaka, Y.; Takenaga, M.; Ogawa, M.; Shinde, J.; Iwazaki, K.; Shinto, K.; Kitajima, S.; Sasao, M.; Nishimura, K.; Inagaki, S.

    2005-01-01

    In the Tohoku University Heliac (TU-Heliac), the influence of a radial electric field on improved modes has been investigated by an electrode biasing. In both positive and negative biasing experiments by the stainless steel (SUS) electrode (cold-electron or ion collection), the improvement of plasma confinement was clearly observed. Furthermore, by negative biasing with a hot cathode (electron injection), the radial electric fields can be actively controlled as a consequence of the control of the electrode current I E . By using the electrode made of a hydrogen storage metal, for example Titanium (Ti) or Vanadium (V), the following possibility can be expected: (1) ions accelerated from the positive biased electrode allow the simulation for the orbit loss of high-energy particles, (2) the electrons/neutral- particles injected from the negative biased electrode provide the production of the high- density plasma, if hydrogen are successfully stored in the electrode. In this present work, several methods were tried as the treatment for hydrogen storage. In the case of the Ti electrode biased positively after the treatment, the improvement of plasma confinement was observed in He plasma, which were same as the experimental results of the SUS electrode. However, in the electron density profiles inside the electrode position there was difference between the biased plasma by the Ti electrode and that by the SUS electrode. In some of Ar discharges biased negatively with the Ti electrode after the treatment, the electron density and the line intensity of H α increased about 10 times of those before biasing. This phenomenon has not been observed in the Ar plasma biased by the SUS electrode. This result suggested that the Ti electrode injected electrons/neutral-hydrogen into the plasma. This high-density plasma productions were observed only 1 ∼ 3 times in the one treatment for hydrogen storage. By using a Vanadium (V) electrode, productions of the high-density plasma

  18. Evaluation of the tripolar electrode stimulation method by numerical analysis and animal experiments for cochlear implants.

    Science.gov (United States)

    Miyoshi, S; Sakajiri, M; Ifukube, T; Matsushima, J

    1997-01-01

    We have proposed the Tripolar Electrode Stimulation Method (TESM) which may enable us to narrow the stimulation region and to move continuously the stimulation site for the cochlear implants. We evaluated whether or not TESM works according to a theory based on numerical analysis using the auditory nerve fiber model. In this simulation, the sum of the excited model fibers were compared with the compound actions potentials obtained from animal experiments. As a result, this experiment showed that TESM could narrow a stimulation region by controlling the sum of the currents emitted from the electrodes on both sides, and continuously move a stimulation site by changing the ratio of the currents emitted from the electrodes on both sides.

  19. Theory and experiment on charging and discharging a capacitor through a reverse-biased diode

    Science.gov (United States)

    Roy, Arijit; Mallick, Abhishek; Adhikari, Aparna; Guin, Priyanka; Chatterjee, Dibyendu

    2018-06-01

    The beauty of a diode lies in its voltage-dependent nonlinear resistance. The voltage on a charging and discharging capacitor through a reverse-biased diode is calculated from basic equations and is found to be in good agreement with experimental measurements. Instead of the exponential dependence of charging and discharging voltages with time for a resistor-capacitor circuit, a linear time dependence is found when the resistor is replaced by a reverse-biased diode. Thus, well controlled positive and negative ramp voltages are obtained from the charging and discharging diode-capacitor circuits. This experiment can readily be performed in an introductory physics and electronics laboratory.

  20. Studying Gender Bias in Physics Grading: The role of teaching experience and country

    Science.gov (United States)

    Hofer, Sarah I.

    2015-11-01

    The existence of gender-STEM (science, technology, engineering, and mathematics) stereotypes has been repeatedly documented. This article examines physics teachers' gender bias in grading and the influence of teaching experience in Switzerland, Austria, and Germany. In a 2 × 2 between-subjects design, with years of teaching experience included as moderating variable, physics teachers (N = 780) from Switzerland, Austria, and Germany graded a fictive student's answer to a physics test question. While the answer was exactly the same for each teacher, only the student's gender and specialization in languages vs. science were manipulated. Specialization was included to gauge the relative strength of potential gender bias effects. Multiple group regression analyses, with the grade that was awarded as the dependent variable, revealed only partial cross-border generalizability of the effect pattern. While the overall results in fact indicated the existence of a consistent and clear gender bias against girls in the first part of physics teachers' careers that disappeared with increasing teaching experience for Swiss teachers, Austrian teachers, and German female teachers, German male teachers showed no gender bias effects at all. The results are discussed regarding their relevance for educational practice and research.

  1. Explicit Bias Toward High-Income-Country Research: A Randomized, Blinded, Crossover Experiment Of English Clinicians.

    Science.gov (United States)

    Harris, Matthew; Marti, Joachim; Watt, Hillary; Bhatti, Yasser; Macinko, James; Darzi, Ara W

    2017-11-01

    Unconscious bias may interfere with the interpretation of research from some settings, particularly from lower-income countries. Most studies of this phenomenon have relied on indirect outcomes such as article citation counts and publication rates; few have addressed or proven the effect of unconscious bias in evidence interpretation. In this randomized, blinded crossover experiment in a sample of 347 English clinicians, we demonstrate that changing the source of a research abstract from a low- to a high-income country significantly improves how it is viewed, all else being equal. Using fixed-effects models, we measured differences in ratings for strength of evidence, relevance, and likelihood of referral to a peer. Having a high-income-country source had a significant overall impact on respondents' ratings of relevance and recommendation to a peer. Unconscious bias can have far-reaching implications for the diffusion of knowledge and innovations from low-income countries.

  2. Reducing Bias in Citizens’ Perception of Crime Rates: Evidence From a Field Experiment on Burglary Prevalence

    DEFF Research Database (Denmark)

    Larsen, Martin Vinæs; Olsen, Asmus Leth

    2018-01-01

    Citizens are on average too pessimistic when assessing the trajectory of current crime trends. In this study, we examine whether we can correct this perceptual bias with respect to burglaries. Using a field experiment coupled with a large panel survey (n=4,895), we explore whether a public...... information campaign can reduce misperceptions about the prevalence of burglaries. Embedding the correct information about burglary rates in a direct mail campaign, we find that it is possible to substantially reduce citizens’ misperceptions. The effects are not short lived – they are detectable several weeks...... after the mailer was sent, but they are temporary. Eventually the perceptual bias re-emerges. Our results suggest that if citizens were continually supplied with correct information about crime rates they would be less pessimistic. Reducing bias in citizens’ perception of crime rates might therefore...

  3. Looking into the future: An inward bias in aesthetic experience driven only by gaze cues.

    Science.gov (United States)

    Chen, Yi-Chia; Colombatto, Clara; Scholl, Brian J

    2018-07-01

    The inward bias is an especially powerful principle of aesthetic experience: In framed images (e.g. photographs), we prefer peripheral figures that face inward (vs. outward). Why does this bias exist? Since agents tend to act in the direction in which they are facing, one intriguing possibility is that the inward bias reflects a preference to view scenes from a perspective that will allow us to witness those predicted future actions. This account has been difficult to test with previous displays, in which facing direction is often confounded with either global shape profiles or the relative locations of salient features (since e.g. someone's face is generally more visually interesting than the back of their head). But here we demonstrate a robust inward bias in aesthetic judgment driven by a cue that is socially powerful but visually subtle: averted gaze. Subjects adjusted the positions of people in images to maximize the images' aesthetic appeal. People with direct gaze were not placed preferentially in particular regions, but people with averted gaze were reliably placed so that they appeared to be looking inward. This demonstrates that the inward bias can arise from visually subtle features, when those features signal how future events may unfold. Copyright © 2018. Published by Elsevier B.V.

  4. Correspondence between Experiment and Theory of Bulk Electrocrystallisation at Solid Electrodes in Aqueous Electrolyte

    DEFF Research Database (Denmark)

    Andersen, Jens Enevold Thaulov

    2009-01-01

    A model of electrodeposition and electrodissolution at electrode surfaces in aqueous solution is presented. The description is based on the assumption that redox reaction of water is the more important process controlling the electrode kinetics. Chronoamperometric measurements and experiments...... of cyclic voltammetry indicate that the current fundamentally is proportional to inverse time. It was proposed that redox-active species different from water never touch the surface but they predominantly interact with surface-active hydrogen or oxygen formed at the surface by redox processes of water...

  5. Gender bias in hospital leadership: a qualitative study on the experiences of women CEOs.

    Science.gov (United States)

    Soklaridis, Sophie; Kuper, Ayelet; Whitehead, Cynthia R; Ferguson, Genevieve; Taylor, Valerie H; Zahn, Catherine

    2017-04-10

    Purpose The purpose of this paper is to examine the experiences of gender bias among women hospital CEOs and explore to what these female leaders attribute their success within a male-dominated hospital executive leadership milieu. Design/methodology/approach This qualitative study involved 12 women hospital CEOs from across Ontario, Canada. Purposeful sampling techniques and in-depth qualitative interview methods were used to facilitate discussion around experiences of gender and leadership. Findings Responses fell into two groups: the first group represented the statement "Gender inequality is alive and well". The second group reflected the statement "Gender inequity is not significant, did not happen to me, and things are better now". This group contained a sub-group with no consciousness of systemic discrimination and that claimed having no gendered experiences in their leadership journey. The first group described gender issues in various contexts, from the individual to the systemic. The second group was ambivalent about gender as a factor impacting leadership trajectories. Originality/value Representations of women's leadership have become detached from feminism, with major consequences for women. This study reveals how difficult it is for some women CEOs to identify gender bias. The subtle everyday norms and practices within the workplace make it difficult to name and explain gender bias explicitly and may explain the challenges in understanding how it might affect a woman's career path.

  6. Multicenter surgical experience evaluation on the Mid-Scala electrode and insertion tools.

    Science.gov (United States)

    Gazibegovic, Dzemal; Bero, Eva M

    2017-02-01

    The HiFocus Mid-Scala electrode is intended to improve hearing for individuals with severe-to-profound hearing loss by providing extended electrical coverage of the cochlea while minimizing trauma related to insertion. The electrode is appropriate for use with a wide range of surgical techniques, including either a cochleostomy or round window insertion, and the use of either a free-hand or tool-assisted approach. The objective of this survey was to evaluate how the HiFocus Mid-Scala electrode and insertion tools was used across a population of cochlear implant recipients of differing ages, audiologic profiles, and anatomical characteristics. The intent was to understand the type and frequency of surgical techniques applicable with the electrode, and to provide guidelines for clinical practice. Two questionnaires were completed by surgeons at implant centres located in the United States, Europe, and Asia. Before any surgeries were conducted, surgeons completed a questionnaire that assessed their overall cochlear implant surgical practice and preferences. Following each HiFocus Mid-Scala electrode insertion, surgeons completed a questionnaire that summarized their experience during that surgical procedure. Questionnaires were completed by 32 surgeons from 16 centres for a total of 143 surgeries (112 adults, 31 children). Most surgeons (62 %) preferred to insert the electrode via the round window or an extended round window compared with a cochleostomy (16 %), whereas the remaining 22 % indicated that they made an insertion choice based on presenting anatomy. Sixty-nine percent preferred a free-hand approach over using insertion tools. In 32 procedures, surgeons elected to deviate from an intended round window insertion to either an extended round window or cochleostomy approach.

  7. Characterization of 3 mm glass electrodes and development of RPC detectors for INO-ICAL experiment

    Energy Technology Data Exchange (ETDEWEB)

    Kaur, Daljeet; Kumar, Ashok; Gaur, Ankit; Kumar, Purnendu; Hasbuddin, Md.; Mishra, Swati; Kumar, Praveen; Naimuddin, Md., E-mail: nayeem@cern.ch

    2015-02-21

    India-based Neutrino Observatory (INO) is a multi-institutional facility, planned to be built up in South India. The INO facility will host a 51 kton magnetized Iron CALorimeter (ICAL) detector to study atmospheric muon neutrinos. Iron plates have been chosen as the target material whereas Resistive Plate Chambers (RPCs) have been chosen as the active detector element for the ICAL experiment. Due to the large number of RPCs needed (∼28,000 of 2 m×2 m in size) for ICAL experiment and for the long lifetime of the experiment, it is necessary to perform a detailed R and D such that each and every parameter of the detector performance can be optimized to improve the physics output. In this paper, we report on the detailed material and electrical properties studies for various types of glass electrodes available locally. We also report on the performance studies carried out on the RPCs made with these electrodes as well as the effect of gas composition and environmental temperature on the detector performance. We also lay emphasis on the usage of materials for RPC electrodes and the suitable environmental conditions applicable for operating the RPC detector for optimal physics output at INO-ICAL experiment.

  8. No Own-Age Bias in 3-Year-Old Children: More Evidence for the Role of Early Experience in Building Face-Processing Biases

    Science.gov (United States)

    Cassia, Viola Macchi; Pisacane, Antonella; Gava, Lucia

    2012-01-01

    This study aimed to investigate the presence of an own-age bias in young children who accumulated different amounts of early experience with child faces. Discrimination abilities for upright and inverted adult and child faces were tested using a delayed two-alternative, forced-choice matching-to-sample task in two groups of 3-year-old children,…

  9. Numerical experiment on variance biases and Monte Carlo neutronics analysis with thermal hydraulic feedback

    International Nuclear Information System (INIS)

    Hyung, Jin Shim; Beom, Seok Han; Chang, Hyo Kim

    2003-01-01

    Monte Carlo (MC) power method based on the fixed number of fission sites at the beginning of each cycle is known to cause biases in the variances of the k-eigenvalue (keff) and the fission reaction rate estimates. Because of the biases, the apparent variances of keff and the fission reaction rate estimates from a single MC run tend to be smaller or larger than the real variances of the corresponding quantities, depending on the degree of the inter-generational correlation of the sample. We demonstrate this through a numerical experiment involving 100 independent MC runs for the neutronics analysis of a 17 x 17 fuel assembly of a pressurized water reactor (PWR). We also demonstrate through the numerical experiment that Gelbard and Prael's batch method and Ueki et al's covariance estimation method enable one to estimate the approximate real variances of keff and the fission reaction rate estimates from a single MC run. We then show that the use of the approximate real variances from the two-bias predicting methods instead of the apparent variances provides an efficient MC power iteration scheme that is required in the MC neutronics analysis of a real system to determine the pin power distribution consistent with the thermal hydraulic (TH) conditions of individual pins of the system. (authors)

  10. Simulation of a two-dimensional sheath over a flat insulator-conductor interface on a radio-frequency biased electrode in a high-density plasma

    International Nuclear Information System (INIS)

    Kim, Doosik; Economou, Demetre J.

    2004-01-01

    A combined fluid/Monte Carlo (MC) simulation was developed to study the two-dimensional (2D) sheath over a flat insulator/conductor interface on a radio-frequency (rf) biased electrode in a high-density plasma. The insulator capacitance increased the local impedance between the plasma and the bias voltage source. Thus, for uniform ion density and electron temperature far away from the wall, the sheath potential over the insulator was only a fraction of that over the conductor, resulting in a thinner sheath over the insulator. The fluid model provided the spatiotemporal profiles of the 2D sheath electric field. These were used as input to the MC simulation to compute the ion energy distribution (IED) and ion angular distribution (IAD) at different locations on the surface. The ion flux, IED, and IAD changed drastically across the insulator/conductor interface due to the diverging rf electric field in the distorted sheath. The ion flux was larger on the conductor at the expense of that on the insulator. Both the ion impact angle and angular spread increased progressively as the material interface was approached. The ion impact energy and energy spread were smaller on the insulator as compared to the conductor. For given plasma parameters, as the insulator thickness was increased, the sheath potential and thickness over the insulator decreased, and sheath distortion became more pronounced

  11. Three-dimensional modeling of a negative ion source with a magnetic filter: impact of biasing the plasma electrode on the plasma asymmetry

    Science.gov (United States)

    Fubiani, G.; Boeuf, J. P.

    2015-10-01

    The effect on the plasma characteristics of biasing positively the plasma electrode (PE) in negative ion sources with a magnetic filter is analysed using a 3D particle-in-cell model with Monte-Carlo collisions (PIC-MCC). We specialize to the one driver (i.e. one inductively coupled radio-frequency discharge) BATMAN negative ion source and the 4-drivers (large volume) ELISE device. Both are ITER prototype high power tandem-type negative ion sources developed for the neutral beam injector (NBI) system. The plasma is generated in the driver and diffuses inside the second chamber which is magnetized. Asymmetric plasma profiles originate from the formation of an electric field transverse to the electron current flowing through the magnetic filter (Hall effect). The model shows that the importance of the asymmetry increases with the PE bias potential, i.e. with the electron flow from the driver to the extraction region and depends on the shape of the magnetic filter field. We find that although the plasma density and potential profiles may be more or less asymmetric depending on the filter field configuration, the electron current to the plasma grid is always strongly asymmetric.

  12. Three-dimensional modeling of a negative ion source with a magnetic filter: impact of biasing the plasma electrode on the plasma asymmetry

    International Nuclear Information System (INIS)

    Fubiani, G; Boeuf, J P

    2015-01-01

    The effect on the plasma characteristics of biasing positively the plasma electrode (PE) in negative ion sources with a magnetic filter is analysed using a 3D particle-in-cell model with Monte-Carlo collisions (PIC-MCC). We specialize to the one driver (i.e. one inductively coupled radio-frequency discharge) BATMAN negative ion source and the 4-drivers (large volume) ELISE device. Both are ITER prototype high power tandem-type negative ion sources developed for the neutral beam injector (NBI) system. The plasma is generated in the driver and diffuses inside the second chamber which is magnetized. Asymmetric plasma profiles originate from the formation of an electric field transverse to the electron current flowing through the magnetic filter (Hall effect). The model shows that the importance of the asymmetry increases with the PE bias potential, i.e. with the electron flow from the driver to the extraction region and depends on the shape of the magnetic filter field. We find that although the plasma density and potential profiles may be more or less asymmetric depending on the filter field configuration, the electron current to the plasma grid is always strongly asymmetric. (paper)

  13. Initial Operative Experience and Short-term Hearing Preservation Results With a Mid-scala Cochlear Implant Electrode Array.

    Science.gov (United States)

    Svrakic, Maja; Roland, J Thomas; McMenomey, Sean O; Svirsky, Mario A

    2016-12-01

    To describe our initial operative experience and hearing preservation results with the Advanced Bionics (AB) Mid Scala Electrode (MSE). Retrospective review. Tertiary referral center. Sixty-three MSE implants in pediatric and adult patients were compared with age- and sex-matched 1j electrode implants from the same manufacturer. All patients were severe to profoundly deaf. Cochlear implantation with either the AB 1j electrode or the AB MSE. The MSE and 1j electrodes were compared in their angular depth of insertion and pre to postoperative change in hearing thresholds. Hearing preservation was analyzed as a function of angular depth of insertion. Secondary outcome measures included operative time, incidence of abnormal intraoperative impedance and telemetry values, and incidence of postsurgical complications. Depth of insertion was similar for both electrodes, but was more consistent for the MSE array and more variable for the 1j array. Patients with MSE electrodes had better hearing preservation. Thresholds shifts at four audiometric frequencies ranging from 250 to 2000 Hz were 10, 7, 2, and 6 dB smaller for the MSE electrode than for the 1j (p < 0.05). Hearing preservation at low frequencies was worse with deeper insertion, regardless of array. Secondary outcome measures were similar for both electrodes. The MSE electrode resulted in more consistent insertion depth and somewhat better hearing preservation than the 1j electrode. Differences in other surgical outcome measures were small or unlikely to have a meaningful effect.

  14. Thermophysical Property Estimation by Transient Experiments: The Effect of a Biased Initial Temperature Distribution

    Directory of Open Access Journals (Sweden)

    Federico Scarpa

    2015-01-01

    Full Text Available The identification of thermophysical properties of materials in dynamic experiments can be conveniently performed by the inverse solution of the associated heat conduction problem (IHCP. The inverse technique demands the knowledge of the initial temperature distribution within the material. As only a limited number of temperature sensors (or no sensor at all are arranged inside the test specimen, the knowledge of the initial temperature distribution is affected by some uncertainty. This uncertainty, together with other possible sources of bias in the experimental procedure, will propagate in the estimation process and the accuracy of the reconstructed thermophysical property values could deteriorate. In this work the effect on the estimated thermophysical properties due to errors in the initial temperature distribution is investigated along with a practical method to quantify this effect. Furthermore, a technique for compensating this kind of bias is proposed. The method consists in including the initial temperature distribution among the unknown functions to be estimated. In this way the effect of the initial bias is removed and the accuracy of the identified thermophysical property values is highly improved.

  15. Critical bias fields for tilting stability in the BETA-II experiment

    International Nuclear Information System (INIS)

    Dalhed, H.E.

    1981-01-01

    The PEST equilibrium code and the GATO ideal MHD stability code have been modified to study stability properties of Spheromak configurations. Of particular interest is the effect on tilting modes of perfectly conducting walls which do not link the plasma. This paper makes use of equilibria and conducting walls specifically designed to model the BETA-II experiment at LLNL. Onset of the tilting mode is determined as a function of the bias magnetic field. Comparison with available experimental data shows promising agreement with the numerical results

  16. Experience of automation failures in training: effects on trust, automation bias, complacency and performance.

    Science.gov (United States)

    Sauer, Juergen; Chavaillaz, Alain; Wastell, David

    2016-06-01

    This work examined the effects of operators' exposure to various types of automation failures in training. Forty-five participants were trained for 3.5 h on a simulated process control environment. During training, participants either experienced a fully reliable, automatic fault repair facility (i.e. faults detected and correctly diagnosed), a misdiagnosis-prone one (i.e. faults detected but not correctly diagnosed) or a miss-prone one (i.e. faults not detected). One week after training, participants were tested for 3 h, experiencing two types of automation failures (misdiagnosis, miss). The results showed that automation bias was very high when operators trained on miss-prone automation encountered a failure of the diagnostic system. Operator errors resulting from automation bias were much higher when automation misdiagnosed a fault than when it missed one. Differences in trust levels that were instilled by the different training experiences disappeared during the testing session. Practitioner Summary: The experience of automation failures during training has some consequences. A greater potential for operator errors may be expected when an automatic system failed to diagnose a fault than when it failed to detect one.

  17. Maritime Continent seasonal climate biases in AMIP experiments of the CMIP5 multimodel ensemble

    Science.gov (United States)

    Toh, Ying Ying; Turner, Andrew G.; Johnson, Stephanie J.; Holloway, Christopher E.

    2018-02-01

    The fidelity of 28 Coupled Model Intercomparison Project phase 5 (CMIP5) models in simulating mean climate over the Maritime Continent in the Atmospheric Model Intercomparison Project (AMIP) experiment is evaluated in this study. The performance of AMIP models varies greatly in reproducing seasonal mean climate and the seasonal cycle. The multi-model mean has better skill at reproducing the observed mean climate than the individual models. The spatial pattern of 850 hPa wind is better simulated than the precipitation in all four seasons. We found that model horizontal resolution is not a good indicator of model performance. Instead, a model's local Maritime Continent biases are somewhat related to its biases in the local Hadley circulation and global monsoon. The comparison with coupled models in CMIP5 shows that AMIP models generally performed better than coupled models in the simulation of the global monsoon and local Hadley circulation but less well at simulating the Maritime Continent annual cycle of precipitation. To characterize model systematic biases in the AMIP runs, we performed cluster analysis on Maritime Continent annual cycle precipitation. Our analysis resulted in two distinct clusters. Cluster I models are able to capture both the winter monsoon and summer monsoon shift, but they overestimate the precipitation; especially during the JJA and SON seasons. Cluster II models simulate weaker seasonal migration than observed, and the maximum rainfall position stays closer to the equator throughout the year. The tropics-wide properties of these clusters suggest a connection between the skill of simulating global properties of the monsoon circulation and the skill of simulating the regional scale of Maritime Continent precipitation.

  18. Judging Managerial Actions as Ethical or Unethical: Decision Bias and Domain Relevant Experience

    Directory of Open Access Journals (Sweden)

    Jeffrey J. Bailey, Ph.D.

    2013-07-01

    Full Text Available This is an empirical study comparing the susceptibility of managers and students to a decision-making bias when making judgments about ethical business practices. The managers and students read through vignettes and made judgments about how ethical they perceived the described business actions to be. Half of the participants (half of the managers and half of the students were exposed to three situations in which the actions being judged were clearly unethical. The other half of each group was exposed to situations in which the actions being judged were clearly ethical. All were exposed to the same fourth situation of a business decision. In this ambiguous situation it was not clear if the business decision being evaluated was ethical or unethical. The decision bias examined here addressed the question of ‘to what extent does exposure to prior unethical (or ethical actions influence one’s evaluation of how ethical a particular business decision is when it is not a clearly right or wrong action. The results demonstrated that students’ ethical judgments about the action in the fourth scenario (the same scenario for everyone differed depending on what they were previously exposed to. Significant assimilation effects were found in the student sample suggesting support for the perceptual readiness models. The managerial sample yielded differences in the opposite direction, one of a contrast effect, but these did not reach statistical significance. Assimilation effects occurred in the sample without domain relevant experience and contrast effects occurred with the experienced sample. Implications are discussed.

  19. The risk of bias of animal experiments in implant dentistry: a methodological study.

    Science.gov (United States)

    Faggion, Clovis Mariano; Diaz, Karla Tatiana; Aranda, Luisiana; Gabel, Frank; Listl, Stefan; Alarcón, Marco Antonio

    2017-07-01

    To evaluate the risk of bias (ROB) in reports of randomised controlled trials (RCTs) of animal experiments published in implant dentistry, and to explore the association between animal experiment characteristics and ROB. We searched the MEDLINE (via PubMed), SCOPUS and SciELO databases from 2010 to March 2015 for reports of RCTs of animal experiments published in implant dentistry. We evaluated independently and in duplicate the ROB of these experiments by the use of a tool specifically developed to evaluate ROB in animal studies, the SYRCLE's tool. ROB was judged as low, high or unclear (when there was not enough information to judge ROB). We used univariate and multivariate logistic regression analyses to evaluate the association of specific study characteristics and extent of ROB. We initially selected 850 publications and 161 reports of animal experiments were included. For a total of 1449 entries (records), 486 (34%) were rated as low ROB. High ROB was attributed to 80 (6%) of entries, and 883 (60%) entries were rated as unclear ROB. The characteristics "impact factor" (IF), reporting of standard error (SE) and reporting of confidence interval (CI) were significantly associated with low ROB in some SYRCLE domains. A substantial number of items with unclear ROB were observed in this sample of animal experiments in implant dentistry. Furthermore, the present findings suggest that implant dentistry animal experiments published in journals with higher IF and better report of measures of precision; that is, CI and SE may have lower ROB than those not having these characteristics. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  20. Initial Operative Experience and Short Term Hearing Preservation Results with a Mid-Scala Cochlear Implant Electrode Array

    Science.gov (United States)

    Svrakic, Maja; Roland, J. Thomas; McMenomey, Sean O.; Svirsky, Mario A.

    2016-01-01

    OBJECTIVE To describe our initial operative experience and hearing preservation results with the Advanced Bionics (AB) Mid Scala Electrode (MSE) STUDY DESIGN Retrospective review. SETTING Tertiary referral center. PATIENTS Sixty-three MSE implants in pediatric and adult patients were compared to age- and gender-matched 1j electrode implants from the same manufacturer. All patients were severe to profoundly deaf. INTERVENTION Cochlear implantation with either the AB 1j electrode or the AB MSE. MAIN OUTCOME MEASURES The MSE and 1j electrode were compared in their angular depth of insertion (aDOI) and pre- to post-operative change in hearing thresholds. Hearing preservation was analyzed as a function of aDOI. Secondary outcome measures included operative time, incidence of abnormal intraoperative impedance and telemetry values, and incidence of postsurgical complications. RESULTS Depth of insertion was similar for both electrodes, but was more consistent for the MSE array and more variable for the 1j array. Patients with MSE electrodes had better hearing preservation. Thresholds shifts at four audiometric frequencies ranging from 250 to 2,000 Hz were 10 dB, 7 dB, 2 dB and 6 dB smaller for the MSE electrode than for the 1j (p<0.05). Hearing preservation at low frequencies was worse with deeper insertion, regardless of array. Secondary outcome measures were similar for both electrodes. CONCLUSIONS The MSE electrode resulted in more consistent insertion depth and somewhat better hearing preservation than the 1j electrode. Differences in other surgical outcome measures were small or unlikely to have a meaningful effect. PMID:27755356

  1. A LabVIEW based experiment system for the efficient collection and analysis of cyclic voltametry and electrode charge capacity measurements.

    Science.gov (United States)

    Detlefsen, D; Hu, Z; Troyk, P R

    2006-01-01

    Cyclic voltametry and recording of stimulation electrode voltage excursions are two critical methods of measurement for understanding the performance of implantable electrodes. Because implanted electrodes cannot easily be replaced, it is necessary to have an a-priori understanding of an electrode's implanted performance and capabilities. In-vitro exhaustive tests are often needed to quantify an electrodes performance. Using commonly available equipment, the human labor cost to conduct this work is immense. Presented is an automated experiment system that is highly configurable that can efficiently conduct a battery of repeatable CV and stimulation recording measurements. Results of preparing 96 electrodes prior to an animal implantation are also discussed.

  2. The professional socialization of collegiate female athletic trainers: navigating experiences of gender bias.

    Science.gov (United States)

    Mazerolle, Stephanie M; Borland, John F; Burton, Laura J

    2012-01-01

    Female athletic trainers (ATs) experience gender discrimination in the workplace due to stereotypical gender roles, but limited information is available regarding the topic. To understand the challenges and obstacles faced by young female ATs working in National Collegiate Athletic Association Division I athletics. Exploratory study using semistructured interviews. Division I clinical setting. A total of 14 female ATs were included in the study, using both criterion and snowball-sampling techniques. Their mean age was 27 ± 2 years, with 5 ± 2 years of overall clinical experience. Criteria included employment at the Division I clinical setting, being a full-time assistant AT, and at least 3 years of working experience but no more than 9 years to avoid role continuance. Analysis of the interview data followed inductive procedures as outlined by a grounded theory approach. Credibility was established by member checks, multiple-analyst triangulation, and peer review. Clear communication with both coaches and players about expectations and philosophies regarding medical care, a supportive head AT in terms of clinical competence, and having and serving as a role model were cited as critical tools to alleviate gender bias in the workplace. The female ATs in this study stressed the importance of being assertive with coaches early in the season with regard to the AT's role on the team. They reasoned that these actions brought forth a greater perception of congruity between their roles as ATs and their gender and age. We suggest that female athletic training students seek mentors in their field while they complete their coursework and practicums. The ATs in the current study indicated that a mentor, regardless of sex, helped them feel empowered to navigate the male-centric terrain of athletic departments by encouraging them to be assertive and not second-guess their decisions.

  3. Interior renovation of a general practitioner office leads to a perceptual bias on patient experience for over one year.

    Science.gov (United States)

    Gauthey, Jérôme; Tièche, Raphaël; Streit, Sven

    2018-01-01

    Measuring patient experience is key when assessing quality of care but can be biased: A perceptual bias occurs when renovations of the interior design of a general practitioner (GP) office improves how patients assessed quality of care. The aim was to assess the length of perceptual bias and if it could be reproduced after a second renovation. A GP office with 2 GPs in Switzerland was renovated twice within 3 years. We assessed patient experience at baseline, 2 months and 14 months after the first and 3 months after the second renovation. Each time, we invited a sample of 180 consecutive patients that anonymously graded patient experience in 4 domains: appearance of the office; qualities of medical assistants and GPs; and general satisfaction. We compared crude mean scores per domain from baseline until follow-up. In a multivariate model, we adjusted for patient's age, gender and for how long patients had been their GP. At baseline, patients aged 60.9 (17.7) years, 52% females. After the first renovation, we found a regression to the baseline level of patient experience after 14 months except for appearance of the office (pInterior renovation of a GP office probably causes a perceptual bias for >1 year that improves how patients rate quality of care. This bias could be reproduced after a second renovation strengthening a possible causal relationship. These findings imply to appropriately time measurement of patient experience to at least one year after interior renovation of GP practices to avoid environmental changes influences the estimates when measuring patient experience.

  4. Window of cold nuclear fusion and biased-pulse electrolysis experiment

    International Nuclear Information System (INIS)

    Takahashi, Akito; Jida, Toshiyuki; Maekawa, Fujio; Sugimoto, Hisashi; Yoshida, Shigeo

    1989-01-01

    Based on the electron screening effect and the excitation of deuteron harmonic oscillators in palladium lattice, theoretical aspects are given to explain the cold fusion phenomena and the possibility of nuclear heating. A narrow window is proposed to meet ≅ 10 watts per cubic centimeter for the nuclear heating, by the hypothetical excitation-screening model. A relatively wide window is feasible to meet a few fusion events per second per cc under the non-stationary conditions of deuteron-charging and discharging. For stationary lattice conditions, the probability of cold fusion is not feasible at all. To confirm the cold fusion phenomena, a heavy water electrolysis experiment was carried out using biased-pulse-electrolytic currents, expecting the enhancement of cold fusion events under charging and discharging of deuterons. For the neutron detection, a cross-checking system between a recoil-proton scintillation detector and a 3 He thermal neutron detector was employed to see coincident time-patterns of neutron emission from an electrolysis cell. To check the energy of emitted neutrons, pulse height spectrum of the recoil-proton detector was monitored. Up to the D-charging time of 300 hr, neutron yields of 1-2 n/s/cc were obtained for time-intervals of 60-200 hr. From the recoil-proton spectra, it was confirmed that 2.45 MeV neutrons by the D(d, n) 3 He fusion branch were emitted. The observed time-patterns of neutron emission suggest the existence of cold fusion under the charging and discharging conditions. (orig.)

  5. Fair Play: A Study of Scientific Workforce Trainers’ Experience Playing an Educational Video Game about Racial Bias

    Science.gov (United States)

    Kaatz, Anna; Carnes, Molly; Gutierrez, Belinda; Savoy, Julia; Samuel, Clem; Filut, Amarette; Pribbenow, Christine Maidl

    2017-01-01

    Explicit racial bias has decreased in the United States, but racial stereotypes still exist and conspire in multiple ways to perpetuate the underparticipation of Blacks in science careers. Capitalizing on the potential effectiveness of role-playing video games to promote the type of active learning required to increase awareness of and reduce subtle racial bias, we developed the video game Fair Play, in which players take on the role of Jamal, a Black male graduate student in science, who experiences discrimination in his PhD program. We describe a mixed-methods evaluation of the experience of scientific workforce trainers who played Fair Play at the National Institutes of Health Division of Training Workforce Development and Diversity program directors’ meeting in 2013 (n = 47; 76% female, n = 34; 53% nonwhite, n = 26). The evaluation findings suggest that Fair Play can promote perspective taking and increase bias literacy, which are steps toward reducing racial bias and affording Blacks equal opportunities to excel in science. PMID:28450447

  6. Theoretical study on new bias factor methods to effectively use critical experiments for improvement of prediction accuracy of neutronic characteristics

    International Nuclear Information System (INIS)

    Kugo, Teruhiko; Mori, Takamasa; Takeda, Toshikazu

    2007-01-01

    Extended bias factor methods are proposed with two new concepts, the LC method and the PE method, in order to effectively use critical experiments and to enhance the applicability of the bias factor method for the improvement of the prediction accuracy of neutronic characteristics of a target core. Both methods utilize a number of critical experimental results and produce a semifictitious experimental value with them. The LC and PE methods define the semifictitious experimental values by a linear combination of experimental values and the product of exponentiated experimental values, respectively, and the corresponding semifictitious calculation values by those of calculation values. A bias factor is defined by the ratio of the semifictitious experimental value to the semifictitious calculation value in both methods. We formulate how to determine weights for the LC method and exponents for the PE method in order to minimize the variance of the design prediction value obtained by multiplying the design calculation value by the bias factor. From a theoretical comparison of these new methods with the conventional method which utilizes a single experimental result and the generalized bias factor method which was previously proposed to utilize a number of experimental results, it is concluded that the PE method is the most useful method for improving the prediction accuracy. The main advantages of the PE method are summarized as follows. The prediction accuracy is necessarily improved compared with the design calculation value even when experimental results include large experimental errors. This is a special feature that the other methods do not have. The prediction accuracy is most effectively improved by utilizing all the experimental results. From these facts, it can be said that the PE method effectively utilizes all the experimental results and has a possibility to make a full-scale-mockup experiment unnecessary with the use of existing and future benchmark

  7. Face Experience and the Attentional Bias for Fearful Expressions in 6- and 9-Month-Old Infants

    Directory of Open Access Journals (Sweden)

    Kristina Safar

    2017-09-01

    Full Text Available Infants demonstrate an attentional bias toward fearful facial expressions that emerges in the first year of life. The current study investigated whether this attentional bias is influenced by experience with particular face types. Six-month-old (n = 33 and 9-month-old (n = 31 Caucasian infants' spontaneous preference for fearful facial expressions when expressed by own-race (Caucasian or other-race (East Asian faces was examined. Six-month-old infants showed a preference for fearful expressions when expressed by own-race faces, but not when expressed by other-race faces. Nine-month-old infants showed a preference for fearful expressions when expressed by both own-race faces and other-race faces. These results suggest that how infants deploy their attention to different emotional expressions is shaped by experience: Attentional biases might initially be restricted to faces with which infants have the most experience, and later be extended to faces with which they have less experience.

  8. Particle and power balances of hot-filament discharge plasmas in a multi-dipole device in the presence of a positively biased electrode

    International Nuclear Information System (INIS)

    Cho, M.H.; Hershkowitz, N.; Intrator, T.

    1989-01-01

    The plasma potential is typically assumed to float above an anode potential by a few times of an electron temperature (T /e). The difference between the plasma potential and the anode potential can be estimated by considering the particle production and loss. However, it has been reported experimentally that the plasma potential of a steady state plasma can be more negative than the anode potential with a potential dip (-- T /e) in front of the anode. This paper describes particle and power balances to estimate the bulk plasma potential of a hot-filament discharge plasma produced in a multi-dipole plasma device. The bulk plasma potential dependence on positive DC bias applied to an anode is analyzed, and the predicted characteristics of the plasma potential dependence are compared to the experiment. A steady state potential dip in front of an anode is experimentally observed using emissive probes with the zero emission inflection point method, and the conditions for the potential dip formation are derived

  9. Experimental studies of influence of different electrodes on bridging in contaminated transformer oil

    OpenAIRE

    Mahmud, S.; Chen, G.; Golosnoy, I.O.; Wilson, G.; Jarman, P.

    2015-01-01

    Contaminated transformer oil has been tested under non uniform electric fields and the effect of different electrode systems presented in this paper. Three different electric fields were examined i.e. DC, AC and DC biased AC. These experiments revealed that with all the different electrodes arrangements, contaminated particles always formed bridges between electrodes under DC electric field. The bridges were thicker and more particles were attracted with more uniform electric field (spherical...

  10. Effect of combined external uniaxial stress and dc bias on the dielectric property of BaTiO3-based dielectrics in multilayer ceramic capacitor: thermodynamics and experiments

    International Nuclear Information System (INIS)

    Yang Gang; Yue Zhenxing; Sun Tieyu; Gou Huanlin; Li Longtu

    2008-01-01

    The dielectric properties of (Nb, Y)-doped BaTiO 3 in a multilayer ceramic capacitor (MLCC) under combined external uniaxial compressive stress and dc bias field were investigated at room temperature by using a modified Ginsburg-Landau-Devonshire thermodynamic theory and the dielectric measurement. It is found that although dc bias decreases the dielectric properties dominantly, the influence of the external uniaixial compressive stress should not be neglected. When applied along a direction perpendicular to the internal electrode layer in the MLCC, the external uniaixal compressive stress will strengthen the negative effect of dc bias. In contrast, the external uniaxial compressive stress along a direction parallel to the internal electrode layer in the MLCC will increase the dielectric permittivity under dc bias field, i.e. improve the ε-V response of the MLCC. Furthermore, although there is a difference between the calculated permittivity and the measured permittivity, the effects of the combined external uniaxial compressive stress and dc bias field on the dielectric permittivity described through two approaches are in good agreement

  11. Dismissing Children's Perceptions of Their Emotional Experience and Parental Care: Preliminary Evidence of Positive Bias

    Science.gov (United States)

    Borelli, Jessica L.; David, Daryn H.; Crowley, Michael J.; Snavely, Jonathan E.; Mayes, Linda C.

    2013-01-01

    The tendency to perceive caregivers in highly positive terms and to perceive the self as strong and problem-free are two facets of the positive bias characteristic of a dismissing attachment classification in adulthood. However, this link has not yet been examined in children. We evaluated the association between dismissing attachment and positive…

  12. Gate-bias and temperature dependence of charge transport in dinaphtho[2,3-b:2‧,3‧-d]thiophene thin-film transistors with MoO3/Au electrodes

    Science.gov (United States)

    Shaari, Safizan; Naka, Shigeki; Okada, Hiroyuki

    2018-04-01

    We investigated the gate-bias and temperature dependence of the voltage-current (V-I) characteristics of dinaphtho[2,3-b:2‧,3‧-d]thiophene with MoO3/Au electrodes. The insertion of the MoO3 layer significantly improved the device performance. The temperature dependent V-I characteristics were evaluated and could be well fitted by the Schottky thermionic emission model with barrier height under forward- and reverse-biased regimes in the ranges of 33-57 and 49-73 meV, respectively. However, at a gate voltage of 0 V, at which a small activation energy was obtained, we needed to consider another conduction mechanism at the grain boundary. From the obtained results, we concluded that two possible conduction mechanisms governed the charge injection at the metal electrode-organic semiconductor interface: the Schottky thermionic emission model and the conduction model in the organic thin-film layer and grain boundary.

  13. Enhancing emotional experiences to dance through music: the role of valence and arousal in the cross-modal bias.

    Science.gov (United States)

    Christensen, Julia F; Gaigg, Sebastian B; Gomila, Antoni; Oke, Peter; Calvo-Merino, Beatriz

    2014-01-01

    It is well established that emotional responses to stimuli presented to one perceptive modality (e.g., visual) are modulated by the concurrent presentation of affective information to another modality (e.g., auditory)-an effect known as the cross-modal bias. However, the affective mechanisms mediating this effect are still not fully understood. It remains unclear what role different dimensions of stimulus valence and arousal play in mediating the effect, and to what extent cross-modal influences impact not only our perception and conscious affective experiences, but also our psychophysiological emotional response. We addressed these issues by measuring participants' subjective emotion ratings and their Galvanic Skin Responses (GSR) in a cross-modal affect perception paradigm employing videos of ballet dance movements and instrumental classical music as the stimuli. We chose these stimuli to explore the cross-modal bias in a context of stimuli (ballet dance movements) that most participants would have relatively little prior experience with. Results showed (i) that the cross-modal bias was more pronounced for sad than for happy movements, whereas it was equivalent when contrasting high vs. low arousal movements; and (ii) that movement valence did not modulate participants' GSR, while movement arousal did, such that GSR was potentiated in the case of low arousal movements with sad music and when high arousal movements were paired with happy music. Results are discussed in the context of the affective dimension of neuroentrainment and with regards to implications for the art community.

  14. Enhancing emotional experiences to dance through music: the role of valence and arousal in the cross-modal bias

    Directory of Open Access Journals (Sweden)

    Julia F. Christensen

    2014-10-01

    Full Text Available It is well established that emotional responses to stimuli presented to one perceptive modality (e.g. visual are modulated by the concurrent presentation of affective information to another modality (e.g. auditory – an effect known as the cross-modal bias. However, the affective mechanisms mediating this effect are still not fully understood. It remains unclear what role different dimensions of stimulus valence and arousal play in mediating the effect, and to what extent cross-modal influences impact not only our perception and conscious affective experiences, but also our psychophysiological emotional response. We addressed these issues by measuring participants’ subjective emotion ratings and their Galvanic Skin Responses in a cross-modal affect perception paradigm employing videos of ballet dance movements and instrumental classical music as the stimuli. We chose these stimuli to explore the cross-modal bias in a context of stimuli (ballet dance movements that most participants would have relatively little prior experience with. Results showed (i that the cross-modal bias was more pronounced for sad than for happy movements, whereas it was equivalent when contrasting high vs. low arousal movements, and (ii that movement valence did not modulate participants’ GSR, while movement arousal did such that GSR was potentiated in the case of low arousal movements with sad music and when high arousal movements were paired with happy music. Results are discussed in the context of the cross-modal affect perception literature and with regards to implications for the art community.

  15. Bias induced transition from an ohmic to a non-ohmic interface in supramolecular tunneling junctions with Ga2O3/EGaIn top electrodes

    NARCIS (Netherlands)

    Wimbush, K.S.; Fratila, R.M.; Wang, D.D.; Qi, D.C.; Liang, C.; Yuan, L.; Yakovlev, N.; Loh, K.P.; Reinhoudt, D.N.; Velders, A.H.; Nijhuis, C.A.

    2014-01-01

    This study describes that the current rectification ratio, R h equivalent to vertical bar J vertical bar(+2.0 V)/vertical bar J vertical bar(+2.0 V) for supramolecular tunneling junctions with a top-electrode of eutectic gallium indium (EGaIn) that contains a conductive thin (0.7 nm) supporting

  16. The foreign language effect on the self-serving bias: A field experiment in the high school classroom.

    Science.gov (United States)

    van Hugten, Joeri; van Witteloostuijn, Arjen

    2018-01-01

    The rise of bilingual education triggers an important question: which language is preferred for a particular school activity? Our field experiment (n = 120) shows that students (aged 13-15) who process feedback in non-native English have greater self-serving bias than students who process feedback in their native Dutch. By contrast, literature on the foreign-language emotionality effect suggests a weaker self-serving bias in the non-native language, so our result adds nuance to that literature. The result is important to schools as it suggests that teachers may be able to reduce students' defensiveness and demotivation by communicating negative feedback in the native language, and teachers may be able to increase students' confidence and motivation by communicating positive feedback in the foreign language.

  17. Bias polarization study of steam electrolysis by composite oxygen electrode Ba0.5Sr0.5Co0.8Fe0.2O3-δ/BaCe0.4Zr0.4Y0.2O3-δ

    Science.gov (United States)

    Yang, Tao; Shaula, Aliaksandr; Pukazhselvan, D.; Ramasamy, Devaraj; Deng, Jiguang; da Silva, E. L.; Duarte, Ricardo; Saraiva, Jorge A.

    2017-12-01

    The polarization behavior of Ba0.5Sr0.5Co0.8Fe0.2O3-δ-BaCe0.4Zr0.4Y0.2O3-δ (BSCF-BCZY) electrode under steam electrolysis conditions was studied in detail. The composite oxygen electrode supported by BCZY electrolyzer has been assessed as a function of temperature (T), water vapor partial pressures (pH2O), and bias polarization voltage for electrodes of comparable microstructure. The Electrochemical impedance spectra show two depressed arcs in general without bias polarization. And the electrode resistance became smaller with the increase of the bias polarization under the same water vapor partial pressures. The total resistance of the electrode was shown to be significantly affected by temperature, with the same level of pH2O and bias polarization voltage. This result highlights BSCF-BCZY as an effective oxygen electrode under moderate polarization and pH2O conditions.

  18. Experiment of bias probe method at NIRS-18 GHz ECR ion source

    Energy Technology Data Exchange (ETDEWEB)

    Jincho, Kaoru; Yamamoto, Mitsugu; Okada, Takanori; Takasugi, Wataru; Sakuma, Tetsuya; Miyoshi, Tomohiro [Accelerator Engineering Corp., Chiba (Japan); Kitagawa, Atsushi; Muramatsu, Masayuki [National Inst. of Radiological Sciences, Chiba (Japan); Biri, Sandor [Institute of Nuclear Research (ATOMKI), Debrecen (Hungary)

    2000-11-01

    An 18 GHz ECR ion source (NIRS-HEC) has been developed to produce highly charged heavy ions from Ar to Xe. In order to increase the beam intensity of highly charged ion, we tried a technique of supplying cold electrons into the ECR plasma. In this paper, enhancement of the beam intensity is discussed in detail. The bias voltage is applied on the probe to repel cold electrons which flow from a plasma. The output beam current is 130 e{mu}A for Ar{sup 11+}. (J.P.N.)

  19. Experiment of bias probe method at NIRS-18 GHz ECR ion source

    International Nuclear Information System (INIS)

    Jincho, Kaoru; Yamamoto, Mitsugu; Okada, Takanori; Takasugi, Wataru; Sakuma, Tetsuya; Miyoshi, Tomohiro; Kitagawa, Atsushi; Muramatsu, Masayuki; Biri, Sandor

    2000-01-01

    An 18 GHz ECR ion source (NIRS-HEC) has been developed to produce highly charged heavy ions from Ar to Xe. In order to increase the beam intensity of highly charged ion, we tried a technique of supplying cold electrons into the ECR plasma. In this paper, enhancement of the beam intensity is discussed in detail. The bias voltage is applied on the probe to repel cold electrons which flow from a plasma. The output beam current is 130 eμA for Ar 11+ . (J.P.N.)

  20. Observational Evidence for the Effect of Amplification Bias in Gravitational Microlensing Experiments

    Science.gov (United States)

    Han, Cheongho; Jeong, Youngjin; Kim, Ho-Il

    1998-11-01

    Recently Alard, Mao, & Guibert and Alard proposed to detect the shift of a star's image centroid, δx, as a method to identify the lensed source among blended stars. Goldberg & Woźniak actually applied this method to the OGLE-1 database and found that seven of 15 events showed significant centroid shifts of δx >~ 0.2". The amount of centroid shift has been estimated theoretically by Goldberg; however, he treated the problem in general and did not apply it to a particular survey or field and therefore based his estimate on simple toy model luminosity functions (i.e., power laws). In this paper, we construct the expected distribution of δx for Galactic bulge events based on the precise stellar luminosity function observed by Holtzman et al. using the Hubble Space Telescope. Their luminosity function is complete up to MI ~ 9.0 (MV ~ 12), which corresponds to faint M-type stars. In our analysis we find that regular blending cannot produce a large fraction of events with measurable centroid shifts. By contrast, a significant fraction of events would have measurable centroid shifts if they are affected by amplification-bias blending. Therefore, the measurements of large centroid shifts for an important fraction of microlensing events of Goldberg & Woźniak confirm the prediction of Han & Alard that a large fraction of Galactic bulge events are affected by amplification-bias blending.

  1. Through the Eyes of the Beholder: Simulated Eye-movement Experience ("SEE") Modulates Valence Bias in Response to Emotional Ambiguity.

    Science.gov (United States)

    Neta, Maital; Dodd, Michael D

    2018-02-01

    Although some facial expressions provide clear information about people's emotions and intentions (happy, angry), others (surprise) are ambiguous because they can signal both positive (e.g., surprise party) and negative outcomes (e.g., witnessing an accident). Without a clarifying context, surprise is interpreted as positive by some and negative by others, and this valence bias is stable across time. When compared to fearful expressions, which are consistently rated as negative, surprise and fear share similar morphological features (e.g., widened eyes) primarily in the upper part of the face. Recently, we demonstrated that the valence bias was associated with a specific pattern of eye movements (positive bias associated with faster fixation to the lower part of the face). In this follow-up, we identified two participants from our previous study who had the most positive and most negative valence bias. We used their eye movements to create a moving window such that new participants viewed faces through the eyes of one our previous participants (subjects saw only the areas of the face that were directly fixated by the original participants in the exact order they were fixated; i.e., Simulated Eye-movement Experience). The input provided by these windows modulated the valence ratings of surprise, but not fear faces. These findings suggest there are meaningful individual differences in how people process faces, and that these differences impact our emotional perceptions. Furthermore, this study is unique in its approach to examining individual differences in emotion by creating a new methodology adapted from those used primarily in the vision/attention domain. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  2. Pulse-voltammetric glucose detection at gold junction electrodes.

    Science.gov (United States)

    Rassaei, Liza; Marken, Frank

    2010-09-01

    A novel glucose sensing concept based on the localized change or "modulation" in pH within a symmetric gold-gold junction electrode is proposed. A paired gold-gold junction electrode (average gap size ca. 500 nm) is prepared by simultaneous bipotentiostatic electrodeposition of gold onto two closely spaced platinum disk electrodes. For glucose detection in neutral aqueous solution, the potential of the "pH-modulator" electrode is set to -1.5 V vs saturated calomel reference electrode (SCE) to locally increase the pH, and simultaneously, either cyclic voltammetry or square wave voltammetry experiments are conducted at the sensor electrode. A considerable improvement in the sensor electrode response is observed when a normal pulse voltammetry sequence is applied to the modulator electrode (to generate "hydroxide pulses") and the glucose sensor electrode is operated with fixed bias at +0.5 V vs SCE (to eliminate capacitive charging currents). Preliminary data suggest good linearity for the glucose response in the medically relevant 1-10 mM concentration range (corresponding to 0.18-1.8 g L(-1)). Future electroanalytical applications of multidimensional pulse voltammetry in junction electrodes are discussed.

  3. Learning about larceny: experience can bias bumble bees to rob nectar

    DEFF Research Database (Denmark)

    Barker, Jessica Livia; Dornhaus, Anna; Bronstein, Judith

    2018-01-01

    switch between these behaviors. We investigated whether the tendency to rob nectar through previously-made holes (secondary robbing) is influenced by prior foraging experience. In a laboratory experiment, we trained groups of bumble bees (Bombus impatiens) either to visit artificial flowers legitimately...

  4. A Simple Hydrogen Electrode

    Science.gov (United States)

    Eggen, Per-Odd

    2009-01-01

    This article describes the construction of an inexpensive, robust, and simple hydrogen electrode, as well as the use of this electrode to measure "standard" potentials. In the experiment described here the students can measure the reduction potentials of metal-metal ion pairs directly, without using a secondary reference electrode. Measurements…

  5. A potential gender bias in assessing quality of life - a standard gamble experiment among university students.

    Science.gov (United States)

    Obaidi, Leath Al; Mahlich, Jörg

    2015-01-01

    There are several methodologies that can be used for evaluating patients' perception of their quality of life. Most commonly, utilities are directly elicited by means of either the time-trade-off or the standard-gamble method. In both methods, risk attitudes determine the quality of life values. Quality of life values among 31 Austrian undergraduate students were elicited by means of the standard gamble approach. The impact of several variables such as gender, side job, length of study, and living arrangements on the quality of life were identified using different types of regression techniques (ordinary least squares, generalized linear model, Betafit). Significant evidence was found that females are associated with a higher quality of life in all specifications of our estimations. The observed gender differences in quality of life can be attributed to a higher degree of risk aversion of women. A higher risk aversion leads to a higher valuation of given health states and a potential gender bias in health economic evaluations. This result could have implications for health policy planners when it comes to budget allocation decisions.

  6. Understanding Biases in Ribosome Profiling Experiments Reveals Signatures of Translation Dynamics in Yeast.

    Directory of Open Access Journals (Sweden)

    Jeffrey A Hussmann

    2015-12-01

    Full Text Available Ribosome profiling produces snapshots of the locations of actively translating ribosomes on messenger RNAs. These snapshots can be used to make inferences about translation dynamics. Recent ribosome profiling studies in yeast, however, have reached contradictory conclusions regarding the average translation rate of each codon. Some experiments have used cycloheximide (CHX to stabilize ribosomes before measuring their positions, and these studies all counterintuitively report a weak negative correlation between the translation rate of a codon and the abundance of its cognate tRNA. In contrast, some experiments performed without CHX report strong positive correlations. To explain this contradiction, we identify unexpected patterns in ribosome density downstream of each type of codon in experiments that use CHX. These patterns are evidence that elongation continues to occur in the presence of CHX but with dramatically altered codon-specific elongation rates. The measured positions of ribosomes in these experiments therefore do not reflect the amounts of time ribosomes spend at each position in vivo. These results suggest that conclusions from experiments in yeast using CHX may need reexamination. In particular, we show that in all such experiments, codons decoded by less abundant tRNAs were in fact being translated more slowly before the addition of CHX disrupted these dynamics.

  7. Influence of the RF electrode cleanliness on plasma characteristics and dust-particle generation in methane dusty plasmas

    Science.gov (United States)

    Géraud-Grenier, I.; Desdions, W.; Faubert, F.; Mikikian, M.; Massereau-Guilbaud, V.

    2018-01-01

    The methane decomposition in a planar RF discharge (13.56 MHz) leads both to a dust-particle generation in the plasma bulk and to a coating growth on the electrodes. Growing dust-particles fall onto the grounded electrode when they are too heavy. Thus, at the end of the experiment, the grounded electrode is covered by a coating and by fallen dust-particles. During the dust-particle growth, the negative DC self-bias voltage (VDC) increases because fewer electrons reach the RF electrode, leading to a more resistive plasma and to changes in the plasma chemical composition. In this paper, the cleanliness influence of the RF electrode on the dust-particle growth, on the plasma characteristics and composition is investigated. A cleanliness electrode is an electrode without coating and dust-particles on its surface at the beginning of the experiment.

  8. Comprehensive ecosystem model-experiment synthesis using multiple datasets at two temperate forest free-air CO2 enrichment experiments: model performance and compensating biases

    Energy Technology Data Exchange (ETDEWEB)

    Walker, Anthony P [ORNL; Hanson, Paul J [ORNL; DeKauwe, Martin G [Macquarie University; Medlyn, Belinda [Macquarie University; Zaehle, S [Max Planck Institute for Biogeochemistry; Asao, Shinichi [Colorado State University, Fort Collins; Dietze, Michael [University of Illinois, Urbana-Champaign; Hickler, Thomas [Goethe University, Frankfurt, Germany; Huntinford, Chris [Centre for Ecology and Hydrology, Wallingford, United Kingdom; Iversen, Colleen M [ORNL; Jain, Atul [University of Illinois, Urbana-Champaign; Lomas, Mark [University of Sheffield; Luo, Yiqi [University of Oklahoma; McCarthy, Heather R [Duke University; Parton, William [Colorado State University, Fort Collins; Prentice, I. Collin [Macquarie University; Thornton, Peter E [ORNL; Wang, Shusen [Canada Centre for Remote Sensing (CCRS); Wang, Yingping [CSIRO Marine and Atmospheric Research; Warlind, David [Lund University, Sweden; Weng, Ensheng [University of Oklahoma, Norman; Warren, Jeffrey [ORNL; Woodward, F. Ian [University of Sheffield; Oren, Ram [Duke University; Norby, Richard J [ORNL

    2014-01-01

    Free Air CO2 Enrichment (FACE) experiments provide a remarkable wealth of data to test the sensitivities of terrestrial ecosystem models (TEMs). In this study, a broad set of 11 TEMs were compared to 22 years of data from two contrasting FACE experiments in temperate forests of the south eastern US the evergreen Duke Forest and the deciduous Oak Ridge forest. We evaluated the models' ability to reproduce observed net primary productivity (NPP), transpiration and Leaf Area index (LAI) in ambient CO2 treatments. Encouragingly, many models simulated annual NPP and transpiration within observed uncertainty. Daily transpiration model errors were often related to errors in leaf area phenology and peak LAI. Our analysis demonstrates that the simulation of LAI often drives the simulation of transpiration and hence there is a need to adopt the most appropriate of hypothesis driven methods to simulate and predict LAI. Of the three competing hypotheses determining peak LAI (1) optimisation to maximise carbon export, (2) increasing SLA with canopy depth and (3) the pipe model the pipe model produced LAI closest to the observations. Modelled phenology was either prescribed or based on broader empirical calibrations to climate. In some cases, simulation accuracy was achieved through compensating biases in component variables. For example, NPP accuracy was sometimes achieved with counter-balancing biases in nitrogen use efficiency and nitrogen uptake. Combined analysis of parallel measurements aides the identification of offsetting biases; without which over-confidence in model abilities to predict ecosystem function may emerge, potentially leading to erroneous predictions of change under future climates.

  9. L1-Penalized N-way PLS for subset of electrodes selection in BCI experiments

    Science.gov (United States)

    Eliseyev, Andrey; Moro, Cecile; Faber, Jean; Wyss, Alexander; Torres, Napoleon; Mestais, Corinne; Benabid, Alim Louis; Aksenova, Tetiana

    2012-08-01

    Recently, the N-way partial least squares (NPLS) approach was reported as an effective tool for neuronal signal decoding and brain-computer interface (BCI) system calibration. This method simultaneously analyzes data in several domains. It combines the projection of a data tensor to a low dimensional space with linear regression. In this paper the L1-Penalized NPLS is proposed for sparse BCI system calibration, allowing uniting the projection technique with an effective selection of subset of features. The L1-Penalized NPLS was applied for the binary self-paced BCI system calibration, providing selection of electrodes subset. Our BCI system is designed for animal research, in particular for research in non-human primates.

  10. Operator Bias in the Estimation of Arc Efficiency in Gas Tungsten Arc Welding

    Directory of Open Access Journals (Sweden)

    Fredrik Sikström

    2015-03-01

    Full Text Available In this paper the operator bias in the measurement process of arc efficiency in stationary direct current electrode negative gas tungsten arc welding is discussed. An experimental study involving 15 operators (enough to reach statistical significance has been carried out with the purpose to estimate the arc efficiency from a specific procedure for calorimetric experiments. The measurement procedure consists of three manual operations which introduces operator bias in the measurement process. An additional relevant experiment highlights the consequences of estimating the arc voltage by measuring the potential between the terminals of the welding power source instead of measuring the potential between the electrode contact tube and the workpiece. The result of the study is a statistical evaluation of the operator bias influence on the estimate, showing that operator bias is negligible in the estimate considered here. On the contrary the consequences of neglecting welding leads voltage drop results in a significant under estimation of the arc efficiency.

  11. Gas shielded metal arc welding with fusible electrode wire. First returns on experience and opportunities in nuclear maintenance and fabrication

    International Nuclear Information System (INIS)

    Huguet, Fr.; Joly, P.; Leconte, F.; Baritaux, S.; Prin, C.

    2013-06-01

    In a brief text and a Power Point Presentation, the authors report a return on experience for the implementation of two applications using gas shielded metal arc welding process (GMAW): the on-site welding of the final joint of steam generators, and the coating of a tubing flare. In the first case, the authors analyze not only the compliance with specified technical requirements, but also outline the need to support the process with new verification methods in real time, associated development and validation efforts, and organisational and decisional measures to guarantee a good implementation of the process on site. In the second case, they analyze the process ability to meet technical specifications requiring dilution control, a perfect reproducibility, as well a good control of the welding bath. The authors outline that these two applications which are both using the same term (gas shielded metal arc welding with fusible electrode wire), implement two different transfer regimes and processes. They also discuss operational constraints, and technical opportunities and constraints of fusible electrode wire

  12. INTERPRETATION OF POTENTIAL INTERMITTENCE TITRATION TECHNIQUE EXPERIMENTS FOR VARIOUS Li-INTERCALATION ELECTRODES

    Directory of Open Access Journals (Sweden)

    M.D.Levi

    2002-01-01

    Full Text Available In this paper we compare two different approaches for the calculation of the enhancement factor Wi, based on its definition as the ratio of the chemical and the component diffusion coefficients for species in mixed-conduction electrodes, originated from the "dilute solution" or "lattice gas" models for the ion system. The former approach is only applicable for small changes of the ion concentration while the latter allows one to consider a broad range of intercalation levels. The component diffusion coefficient of lithium ions has been determined for a series of lithium intercalation anodes and cathodes. A new "enhancement factor" for the ion transport has been defined and its relations to the intercalation capacitance and the intercalation isotherm have been established. A correlation between the dependences of the differential capacitance and the partial ion conductivity on the potential has been observed. It is considered as a prove that the intercalation process is controlled by the availability of sites for Li-ion insertion rather than by the concurrent insertion of the counter-balancing electronic species.

  13. Development and deployment of an inner detector minimum bias trigger and analysis of minimum bias data of the ATLAS experiment at the large hadron collider

    International Nuclear Information System (INIS)

    Kwee, Regina Esther

    2012-01-01

    Soft inelastic QCD processes are the dominant proton-proton interaction type at the LHC. More than 20 of such collisions pile up within a single bunch-crossing at ATLAS, when the LHC is operated at design luminosity of L=10 34 cm -2 s -1 colliding proton bunches with an energy of √(s)=14 TeV. Inelastic interactions are characterised by a small transverse momentum transfer and can only be approximated by phenomenological models that need experimental data as input. The initial phase of LHC beam operation in 2009, with luminosities ranging from L=10 27 to 10 31 cm -2 s -1 , offered an ideal period to select single proton-proton interactions and study general aspects of their properties. As first part of this thesis, a Minimum Bias trigger was developed and used for data-taking in ATLAS. This trigger, mbSpTrk, processes signals of the silicon tracking detectors of ATLAS and was designed to fulfill efficiently reject empty events, while possible biases in the selection of proton-proton collisions is reduced to a minimum. The trigger is flexible enough to cope also with changing background conditions allowing to retain low-p T events while machine background is highly suppressed. As second part, measurements of inelastic charged particles were performed in two phase-space regions. Centrally produced charged particles were considered with a pseudorapidity smaller than 0.8 and a transverse momentum of at least 0.5 or 1 GeV. Four characteristic distributions were measured at two centre-of-mass energies of √(s)=0.9 and 7 TeV. The results are presented with minimal model dependency to compare them to predictions of different Monte Carlo models for soft particle production. This analysis represents also the ATLAS contribution for the first common LHC analysis to which the ATLAS, CMS and ALICE collaborations agreed. The pseudorapidity distributions for both energies and phase-space regions are compared to the respective results of ALICE and CMS.

  14. Development and deployment of an inner detector minimum bias trigger and analysis of minimum bias data of the ATLAS experiment at the large hadron collider

    Energy Technology Data Exchange (ETDEWEB)

    Kwee, Regina Esther

    2012-01-13

    Soft inelastic QCD processes are the dominant proton-proton interaction type at the LHC. More than 20 of such collisions pile up within a single bunch-crossing at ATLAS, when the LHC is operated at design luminosity of L=10{sup 34} cm{sup -2}s{sup -1} colliding proton bunches with an energy of {radical}(s)=14 TeV. Inelastic interactions are characterised by a small transverse momentum transfer and can only be approximated by phenomenological models that need experimental data as input. The initial phase of LHC beam operation in 2009, with luminosities ranging from L=10{sup 27} to 10{sup 31} cm{sup -2}s{sup -1}, offered an ideal period to select single proton-proton interactions and study general aspects of their properties. As first part of this thesis, a Minimum Bias trigger was developed and used for data-taking in ATLAS. This trigger, mbSpTrk, processes signals of the silicon tracking detectors of ATLAS and was designed to fulfill efficiently reject empty events, while possible biases in the selection of proton-proton collisions is reduced to a minimum. The trigger is flexible enough to cope also with changing background conditions allowing to retain low-p{sub T} events while machine background is highly suppressed. As second part, measurements of inelastic charged particles were performed in two phase-space regions. Centrally produced charged particles were considered with a pseudorapidity smaller than 0.8 and a transverse momentum of at least 0.5 or 1 GeV. Four characteristic distributions were measured at two centre-of-mass energies of {radical}(s)=0.9 and 7 TeV. The results are presented with minimal model dependency to compare them to predictions of different Monte Carlo models for soft particle production. This analysis represents also the ATLAS contribution for the first common LHC analysis to which the ATLAS, CMS and ALICE collaborations agreed. The pseudorapidity distributions for both energies and phase-space regions are compared to the respective

  15. On a problematic procedure to manipulate response biases in recognition experiments: the case of "implied" base rates.

    Science.gov (United States)

    Bröder, Arndt; Malejka, Simone

    2017-07-01

    The experimental manipulation of response biases in recognition-memory tests is an important means for testing recognition models and for estimating their parameters. The textbook manipulations for binary-response formats either vary the payoff scheme or the base rate of targets in the recognition test, with the latter being the more frequently applied procedure. However, some published studies reverted to implying different base rates by instruction rather than actually changing them. Aside from unnecessarily deceiving participants, this procedure may lead to cognitive conflicts that prompt response strategies unknown to the experimenter. To test our objection, implied base rates were compared to actual base rates in a recognition experiment followed by a post-experimental interview to assess participants' response strategies. The behavioural data show that recognition-memory performance was estimated to be lower in the implied base-rate condition. The interview data demonstrate that participants used various second-order response strategies that jeopardise the interpretability of the recognition data. We thus advice researchers against substituting actual base rates with implied base rates.

  16. In-line monitoring of Li-ion battery electrode porosity and areal loading using active thermal scanning - modeling and initial experiment

    Science.gov (United States)

    Rupnowski, Przemyslaw; Ulsh, Michael; Sopori, Bhushan; Green, Brian G.; Wood, David L.; Li, Jianlin; Sheng, Yangping

    2018-01-01

    This work focuses on a new technique called active thermal scanning for in-line monitoring of porosity and areal loading of Li-ion battery electrodes. In this technique a moving battery electrode is subjected to thermal excitation and the induced temperature rise is monitored using an infra-red camera. Static and dynamic experiments with speeds up to 1.5 m min-1 are performed on both cathodes and anodes and a combined micro- and macro-scale finite element thermal model of the system is developed. It is shown experimentally and through simulations that during thermal scanning the temperature profile generated in an electrode depends on both coating porosity (or area loading) and thickness. It is concluded that by inverting this relation the porosity (or areal loading) can be determined, if thermal response and thickness are simultaneously measured.

  17. Studying the thermal performance of a bipolar radiofrequency ablation with an improved electrode matrix system: In vitro experiments and modelling

    International Nuclear Information System (INIS)

    Shao, Y.L.; Leo, H.L.; Chua, K.J.

    2017-01-01

    Highlights: • We made judicious modification to the Penne’s equation in the process of developing our model. We consider the liver to consist of tumor and health tissue. The model has been validated with experimental data. • The proposed electrode system can reduce the tissue volume damage outside the electrodes. The designed building unit with 10 mm inter-electrode distance is the optimal choice to achieve desired ablation zone. • The influence of blood vessel is relatively small for using this electrode system. A spatial distance of 13 mm is deemed as the safe distance between the wall of the central probe and the large vessel. • This proposed electrode system demonstrated higher ablation stability even for tissue regions that are close to blood vessels. The system is better suited for matrix-type RFA. - Abstract: Radiofrequency ablation (RFA) is becoming an effective treatment method for both primary tumors and tumors that have metastasized. Large tumors in difficult anatomic locations can be treated by RFA technologies. However, constant size and regular shape of damage zones cannot be obtained by recent RFA technologies. The aim of this study is to optimize the stability of RFA treatment by employing a newly proposed bipolar electrode system. A hepatic RFA mathematical model is developed by the finite element method approach. The model is validated with the experimental data. This model is then used to verify the reliability and stability of the proposed electrode system. Simulated results showed the cross section of the ablation zone utilizing designed electrode system approximates a square. In addition, the fraction of the necrosed tissue with this electrode pattern turned out to be larger than the fraction with single-probe RFA techniques. This system demonstrated higher ablation stability even for tissue regions that are close to blood vessels. The proposed electrode system is better suited for matrix-type RFA.

  18. Large gap plasma display cell with auxiliary electrodes: macro-cell experiments and two-dimensional modelling

    International Nuclear Information System (INIS)

    Ouyang, J T; Callegari, Th; Caillier, B; Boeuf, J-P

    2003-01-01

    In this paper we use a two-dimensional fluid model and a 'macroscopic' PDP cell to investigate the possibility of using large gap configurations with auxiliary electrodes to improve the efficiency of PDP discharge cells. The large gap allows operation in a transient positive column regime where energy is more efficiently deposited into xenon excitation, while the auxiliary electrodes are used to keep reasonable values of the operating voltage. Two types of auxiliary electrode configurations (floating and powered) are considered. The discharge characteristics and the discharge efficiency in exciting xenon are studied with simulations and by measuring the intensity of infrared emission from xenon and visible emission from neon in a macroscopic PDP cell. The results show that an efficient positive column regime can be achieved at reasonably low operating voltages when the auxiliary electrode configuration is carefully designed

  19. Fair Play: A Study of Scientific Workforce Trainers' Experience Playing an Educational Video Game about Racial Bias

    Science.gov (United States)

    Katz, Anna; Carnes, Molly; Gutierrez, Belinda; Savoy, Julia; Samuel, Clem; Filut, Amarette; Pribbenow, Christine Maidl

    2017-01-01

    Explicit racial bias has decreased in the United States, but racial stereotypes still exist and conspire in multiple ways to perpetuate the underparticipation of Blacks in science careers. Capitalizing on the potential effectiveness of role-playing video games to promote the type of active learning required to increase awareness of and reduce…

  20. Open-Source Low-Cost Wireless Potentiometric Instrument for pH Determination Experiments

    Science.gov (United States)

    Jin, Hao; Qin, Yiheng; Pan, Si; Alam, Arif U.; Dong, Shurong; Ghosh, Raja; Deen, M. Jamal

    2018-01-01

    pH determination is an essential experiment in many chemistry laboratories. It requires a potentiometric instrument with extremely low input bias current to accurately measure the voltage between a pH sensing electrode and a reference electrode. In this technology report, we propose an open-source potentiometric instrument for pH determination…

  1. Sympathetic bias.

    Science.gov (United States)

    Levy, David M; Peart, Sandra J

    2008-06-01

    We wish to deal with investigator bias in a statistical context. We sketch how a textbook solution to the problem of "outliers" which avoids one sort of investigator bias, creates the temptation for another sort. We write down a model of the approbation seeking statistician who is tempted by sympathy for client to violate the disciplinary standards. We give a simple account of one context in which we might expect investigator bias to flourish. Finally, we offer tentative suggestions to deal with the problem of investigator bias which follow from our account. As we have given a very sparse and stylized account of investigator bias, we ask what might be done to overcome this limitation.

  2. Safety of atrial fibrillation ablation with novel multi-electrode array catheters on uninterrupted anticoagulation-a single-center experience.

    LENUS (Irish Health Repository)

    Hayes, Christopher Ruslan

    2012-02-01

    INTRODUCTION: A recent single-center report indicated that the performance of atrial fibrillation ablation in patients on uninterrupted warfarin using a conventional deflectable tip electrode ablation catheter may be as safe as periprocedural discontinuation of warfarin and bridging with heparin. Novel multi-electrode array catheters for atrial fibrillation ablation are currently undergoing clinical evaluation. While offering the possibility of more rapid atrial fibrillation ablation, they are stiffer and necessitate the deployment of larger deflectable transseptal sheaths, and it remains to be determined if they increase the risk of cardiac perforation and vascular injury. Such potential risks would have implications for a strategy of uninterrupted periprocedural anticoagulation. METHOD AND RESULTS: We audited the safety outcomes of our atrial fibrillation ablation procedures using multi-electrode array ablation catheters in patients on uninterrupted warfarin (CHADS2 score>or=2) and in patients not on warfarin (uninterrupted aspirin). Two bleeding complications occurred in 49 patients on uninterrupted warfarin, both of which were managed successfully without longterm sequelae, and no bleeding complication occurred in 32 patients not on warfarin (uninterrupted aspirin). There were no thromboembolic events or other complication with either anticoagulant regimen. CONCLUSION: Despite the larger diameter and increased stiffness of multi-electrode array catheters and their deflectable transseptal sheaths, their use for catheter ablation in patients with atrial fibrillation on uninterrupted warfarin in this single-center experience does not appear to be unsafe, and thus, an adequately powered multicenter prospective randomized controlled trial should be considered.

  3. Nonresponse bias in randomized controlled experiments in criminology: Putting the Queensland Community Engagement Trial (QCET) under a microscope.

    Science.gov (United States)

    Antrobus, Emma; Elffers, Henk; White, Gentry; Mazerolle, Lorraine

    2013-01-01

    The goal of this article is to examine whether or not the results of the Queensland Community Engagement Trial (QCET)-a randomized controlled trial that tested the impact of procedural justice policing on citizen attitudes toward police-were affected by different types of nonresponse bias. We use two methods (Cochrane and Elffers methods) to explore nonresponse bias: First, we assess the impact of the low response rate by examining the effects of nonresponse group differences between the experimental and control conditions and pooled variance under different scenarios. Second, we assess the degree to which item response rates are influenced by the control and experimental conditions. Our analysis of the QCET data suggests that our substantive findings are not influenced by the low response rate in the trial. The results are robust even under extreme conditions, and statistical significance of the results would only be compromised in cases where the pooled variance was much larger for the nonresponse group and the difference between experimental and control conditions was greatly diminished. We also find that there were no biases in the item response rates across the experimental and control conditions. RCTs that involve field survey responses-like QCET-are potentially compromised by low response rates and how item response rates might be influenced by the control or experimental conditions. Our results show that the QCET results were not sensitive to the overall low response rate across the experimental and control conditions and the item response rates were not significantly different across the experimental and control groups. Overall, our analysis suggests that the results of QCET are robust and any biases in the survey responses do not significantly influence the main experimental findings.

  4. Does attention bias modification improve attentional control? A double-blind randomized experiment with individuals with social anxiety disorder.

    Science.gov (United States)

    Heeren, Alexandre; Mogoaşe, Cristina; McNally, Richard J; Schmitz, Anne; Philippot, Pierre

    2015-01-01

    People with anxiety disorders often exhibit an attentional bias for threat. Attention bias modification (ABM) procedure may reduce this bias, thereby diminishing anxiety symptoms. In ABM, participants respond to probes that reliably follow non-threatening stimuli (e.g., neutral faces) such that their attention is directed away from concurrently presented threatening stimuli (e.g., disgust faces). Early studies showed that ABM reduced anxiety more than control procedures lacking any contingency between valenced stimuli and probes. However, recent work suggests that no-contingency training and training toward threat cues can be as effective as ABM in reducing anxiety, implying that any training may increase executive control over attention, thereby helping people inhibit their anxious thoughts. Extending this work, we randomly assigned participants with DSM-IV diagnosed social anxiety disorder to either training toward non-threat (ABM), training toward threat, or no-contingency condition, and we used the attention network task (ANT) to assess all three components of attention. After two training sessions, subjects in all three conditions exhibited indistinguishably significant declines from baseline to post-training in self-report and behavioral measures of anxiety on an impromptu speech task. Moreover, all groups exhibited similarly significant improvements on the alerting and executive (but not orienting) components of attention. Implications for ABM research are discussed. Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. Are Health State Valuations from the General Public Biased? A Test of Health State Reference Dependency Using Self-assessed Health and an Efficient Discrete Choice Experiment.

    Science.gov (United States)

    Jonker, Marcel F; Attema, Arthur E; Donkers, Bas; Stolk, Elly A; Versteegh, Matthijs M

    2017-12-01

    Health state valuations of patients and non-patients are not the same, whereas health state values obtained from general population samples are a weighted average of both. The latter constitutes an often-overlooked source of bias. This study investigates the resulting bias and tests for the impact of reference dependency on health state valuations using an efficient discrete choice experiment administered to a Dutch nationally representative sample of 788 respondents. A Bayesian discrete choice experiment design consisting of eight sets of 24 (matched pairwise) choice tasks was developed, with each set providing full identification of the included parameters. Mixed logit models were used to estimate health state preferences with respondents' own health included as an additional predictor. Our results indicate that respondents with impaired health worse than or equal to the health state levels under evaluation have approximately 30% smaller health state decrements. This confirms that reference dependency can be observed in general population samples and affirms the relevance of prospect theory in health state valuations. At the same time, the limited number of respondents with severe health impairments does not appear to bias social tariffs as obtained from general population samples. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  6. Entrapment bias of arthropods in Miocene amber revealed by trapping experiments in a tropical forest in Chiapas, Mexico.

    Science.gov (United States)

    Solórzano Kraemer, Mónica M; Kraemer, Mónica M Solórzano; Kraemer, Atahualpa S; Stebner, Frauke; Bickel, Daniel J; Rust, Jes

    2015-01-01

    All entomological traps have a capturing bias, and amber, viewed as a trap, is no exception. Thus the fauna trapped in amber does not represent the total existing fauna of the former amber forest, rather the fauna living in and around the resin producing tree. In this paper we compare arthropods from a forest very similar to the reconstruction of the Miocene Mexican amber forest, and determine the bias of different trapping methods, including amber. We also show, using cluster analyses, measurements of the trapped arthropods, and guild distribution, that the amber trap is a complex entomological trap not comparable with a single artificial trap. At the order level, the most similar trap to amber is the sticky trap. However, in the case of Diptera, at the family level, the Malaise trap is also very similar to amber. Amber captured a higher diversity of arthropods than each of the artificial traps, based on our study of Mexican amber from the Middle Miocene, a time of climate optimum, where temperature and humidity were probably higher than in modern Central America. We conclude that the size bias is qualitatively independent of the kind of trap for non-extreme values. We suggest that frequent specimens in amber were not necessarily the most frequent arthropods in the former amber forest. Selected taxa with higher numbers of specimens appear in amber because of their ecology and behavior, usually closely related with a tree-inhabiting life. Finally, changes of diversity from the Middle Miocene to Recent time in Central and South America can be analyzed by comparing the rich amber faunas from Mexico and the Dominican Republic with the fauna trapped using sticky and Malaise traps in Central America.

  7. Flexible electrode belt for EIT using nanofiber web dry electrodes.

    Science.gov (United States)

    Oh, Tong In; Kim, Tae Eui; Yoon, Sun; Kim, Kap Jin; Woo, Eung Je; Sadleir, Rosalind J

    2012-10-01

    Efficient connection of multiple electrodes to the body for impedance measurement and voltage monitoring applications is of critical importance to measurement quality and practicality. Electrical impedance tomography (EIT) experiments have generally required a cumbersome procedure to attach the multiple electrodes needed in EIT. Once placed, these electrodes must then maintain good contact with the skin during measurements that may last several hours. There is usually also the need to manage the wires that run between the electrodes and the EIT system. These problems become more severe as the number of electrodes increases, and may limit the practicality and portability of this imaging method. There have been several trials describing human-electrode interfaces using configurations such as electrode belts, helmets or rings. In this paper, we describe an electrode belt we developed for long-term EIT monitoring of human lung ventilation. The belt included 16 embossed electrodes that were designed to make good contact with the skin. The electrodes were fabricated using an Ag-plated PVDF nanofiber web and metallic threads. A large contact area and padding were used behind each electrode to improve subject comfort and reduce contact impedances. The electrodes were incorporated, equally spaced, into an elasticated fabric belt. We tested the electrode belt in conjunction with the KHU Mark1 multi-frequency EIT system, and demonstrate time-difference images of phantoms and human subjects during normal breathing and running. We found that the Ag-plated PVDF nanofiber web electrodes were suitable for long-term measurement because of their flexibility and durability. Moreover, the contact impedance and stability of the Ag-plated PVDF nanofiber web electrodes were found to be comparable to similarly tested Ag/AgCl electrodes.

  8. Ex Vivo Experiment of Saline-Enhanced Hepatic Bipolar Radiofrequency Ablation with a Perfused Needle Electrode: Comparison with Conventional Monopolar and Simultaneous Monopolar Modes

    International Nuclear Information System (INIS)

    Lee, Jeong Min; Kim, Se Hyung; Han, Joon Koo; Sohn, Kyu Li; Choi, Byung Ihn

    2005-01-01

    The purpose of this study was to validate the saline-enhanced bipolar radiofrequency ablation (RFA) technique using a perfused electrode to increase RF-created coagulation necrosis, to compare that technique with monopolar RFAs and to find appropriate concentrations and volumes of perfused NaCl solution for the bipolar RFA. A total of 90 ablations were performed in explanted bovine livers. In the initial experiments to determine appropriate conditions for bipolar RFA, we created five thermal ablation zones in each condition, with instillations of varied concentrations (0.9-36%) or injection rates (30 mL/hr-120 mL/hr) of NaCl solution. After placement of one or two 16-gauge open-perfused electrodes into bovine livers, the NaCl solution was instilled into the tissue through the electrode. In the second part of the study, 10 ablation zones were created using one or two perfused electrodes for each of five groups under different conditions: a conventional monopolar mode with 0.9% NaCl solution (group A) or with 6% NaCl solution (group B), a simultaneous monopolar mode with 6% NaCl solution (group C) and a bipolar mode with 6% NaCl solution (groups D and E). RF was applied to each electrode for 20 min in groups A, B, C, and E, or for 10 min in group D. During RFA, we measured the tissue temperature 15 mm from the electrode. The temperature changes during the RFA and the dimensions of the ablation zones were compared among the groups. Bipolar RFA created larger short-axis diameters of coagulation necrosis with 6% NaCl solution (35.8 ± 15 mm) than with 0.9% NaCl solution (17 ± 9.7 mm) (P 0.05): 31.0 ± 5.4 mm (group A); 28.8 ± 3.8 mm (group B); 25.5 ± 6.4 mm (group C); 32.6 ± 4.2 mm (group D); 49.4 ± 5.0 mm (group E). Bipolar RFA with instillation of 6% NaCl solution through an open perfusion system demonstrates better efficacy in creating a larger ablation zone than does conventional or simultaneous monopolar modes at the various times examined. Therefore

  9. Inappropriate Use of the Quasi-Reversible Electrode Kinetic Model in Simulation-Experiment Comparisons of Voltammetric Processes That Approach the Reversible Limit

    KAUST Repository

    Simonov, Alexandr N.; Morris, Graham P.; Mashkina, Elena A.; Bethwaite, Blair; Gillow, Kathryn; Baker, Ruth E.; Gavaghan, David J.; Bond, Alan M.

    2014-01-01

    Many electrode processes that approach the "reversible" (infinitely fast) limit under voltammetric conditions have been inappropriately analyzed by comparison of experimental data and theory derived from the "quasi-reversible" model. Simulations based on "reversible" and "quasi-reversible" models have been fitted to an extensive series of a.c. voltammetric experiments undertaken at macrodisk glassy carbon (GC) electrodes for oxidation of ferrocene (Fc0/+) in CH3CN (0.10 M (n-Bu)4NPF6) and reduction of [Ru(NH 3)6]3+ and [Fe(CN)6]3- in 1 M KCl aqueous electrolyte. The confidence with which parameters such as standard formal potential (E0), heterogeneous electron transfer rate constant at E0 (k0), charge transfer coefficient (α), uncompensated resistance (Ru), and double layer capacitance (CDL) can be reported using the "quasi- reversible" model has been assessed using bootstrapping and parameter sweep (contour plot) techniques. Underparameterization, such as that which occurs when modeling CDL with a potential independent value, results in a less than optimal level of experiment-theory agreement. Overparameterization may improve the agreement but easily results in generation of physically meaningful but incorrect values of the recovered parameters, as is the case with the very fast Fc0/+ and [Ru(NH3)6]3+/2+ processes. In summary, for fast electrode kinetics approaching the "reversible" limit, it is recommended that the "reversible" model be used for theory-experiment comparisons with only E0, R u, and CDL being quantified and a lower limit of k 0 being reported; e.g., k0 ≥ 9 cm s-1 for the Fc0/+ process. © 2014 American Chemical Society.

  10. Inappropriate Use of the Quasi-Reversible Electrode Kinetic Model in Simulation-Experiment Comparisons of Voltammetric Processes That Approach the Reversible Limit

    KAUST Repository

    Simonov, Alexandr N.

    2014-08-19

    Many electrode processes that approach the "reversible" (infinitely fast) limit under voltammetric conditions have been inappropriately analyzed by comparison of experimental data and theory derived from the "quasi-reversible" model. Simulations based on "reversible" and "quasi-reversible" models have been fitted to an extensive series of a.c. voltammetric experiments undertaken at macrodisk glassy carbon (GC) electrodes for oxidation of ferrocene (Fc0/+) in CH3CN (0.10 M (n-Bu)4NPF6) and reduction of [Ru(NH 3)6]3+ and [Fe(CN)6]3- in 1 M KCl aqueous electrolyte. The confidence with which parameters such as standard formal potential (E0), heterogeneous electron transfer rate constant at E0 (k0), charge transfer coefficient (α), uncompensated resistance (Ru), and double layer capacitance (CDL) can be reported using the "quasi- reversible" model has been assessed using bootstrapping and parameter sweep (contour plot) techniques. Underparameterization, such as that which occurs when modeling CDL with a potential independent value, results in a less than optimal level of experiment-theory agreement. Overparameterization may improve the agreement but easily results in generation of physically meaningful but incorrect values of the recovered parameters, as is the case with the very fast Fc0/+ and [Ru(NH3)6]3+/2+ processes. In summary, for fast electrode kinetics approaching the "reversible" limit, it is recommended that the "reversible" model be used for theory-experiment comparisons with only E0, R u, and CDL being quantified and a lower limit of k 0 being reported; e.g., k0 ≥ 9 cm s-1 for the Fc0/+ process. © 2014 American Chemical Society.

  11. Inappropriate use of the quasi-reversible electrode kinetic model in simulation-experiment comparisons of voltammetric processes that approach the reversible limit.

    Science.gov (United States)

    Simonov, Alexandr N; Morris, Graham P; Mashkina, Elena A; Bethwaite, Blair; Gillow, Kathryn; Baker, Ruth E; Gavaghan, David J; Bond, Alan M

    2014-08-19

    Many electrode processes that approach the "reversible" (infinitely fast) limit under voltammetric conditions have been inappropriately analyzed by comparison of experimental data and theory derived from the "quasi-reversible" model. Simulations based on "reversible" and "quasi-reversible" models have been fitted to an extensive series of a.c. voltammetric experiments undertaken at macrodisk glassy carbon (GC) electrodes for oxidation of ferrocene (Fc(0/+)) in CH3CN (0.10 M (n-Bu)4NPF6) and reduction of [Ru(NH3)6](3+) and [Fe(CN)6](3-) in 1 M KCl aqueous electrolyte. The confidence with which parameters such as standard formal potential (E(0)), heterogeneous electron transfer rate constant at E(0) (k(0)), charge transfer coefficient (α), uncompensated resistance (Ru), and double layer capacitance (CDL) can be reported using the "quasi-reversible" model has been assessed using bootstrapping and parameter sweep (contour plot) techniques. Underparameterization, such as that which occurs when modeling CDL with a potential independent value, results in a less than optimal level of experiment-theory agreement. Overparameterization may improve the agreement but easily results in generation of physically meaningful but incorrect values of the recovered parameters, as is the case with the very fast Fc(0/+) and [Ru(NH3)6](3+/2+) processes. In summary, for fast electrode kinetics approaching the "reversible" limit, it is recommended that the "reversible" model be used for theory-experiment comparisons with only E(0), Ru, and CDL being quantified and a lower limit of k(0) being reported; e.g., k(0) ≥ 9 cm s(-1) for the Fc(0/+) process.

  12. Ultralow-Power Electronic Trapping of Nanoparticles with Sub-10 nm Gold Nanogap Electrodes.

    Science.gov (United States)

    Barik, Avijit; Chen, Xiaoshu; Oh, Sang-Hyun

    2016-10-12

    We demonstrate nanogap electrodes for rapid, parallel, and ultralow-power trapping of nanoparticles. Our device pushes the limit of dielectrophoresis by shrinking the separation between gold electrodes to sub-10 nm, thereby creating strong trapping forces at biases as low as the 100 mV ranges. Using high-throughput atomic layer lithography, we manufacture sub-10 nm gaps between 0.8 mm long gold electrodes and pattern them into individually addressable parallel electronic traps. Unlike pointlike junctions made by electron-beam lithography or larger micron-gap electrodes that are used for conventional dielectrophoresis, our sub-10 nm gold nanogap electrodes provide strong trapping forces over a mm-scale trapping zone. Importantly, our technology solves the key challenges associated with traditional dielectrophoresis experiments, such as high voltages that cause heat generation, bubble formation, and unwanted electrochemical reactions. The strongly enhanced fields around the nanogap induce particle-transport speed exceeding 10 μm/s and enable the trapping of 30 nm polystyrene nanoparticles using an ultralow bias of 200 mV. We also demonstrate rapid electronic trapping of quantum dots and nanodiamond particles on arrays of parallel traps. Our sub-10 nm gold nanogap electrodes can be combined with plasmonic sensors or nanophotonic circuitry, and their low-power electronic operation can potentially enable high-density integration on a chip as well as portable biosensing.

  13. Journal bias or author bias?

    Science.gov (United States)

    Harris, Ian

    2016-01-01

    I read with interest the comment by Mark Wilson in the Indian Journal of Medical Ethics regarding bias and conflicts of interest in medical journals. Wilson targets one journal (the New England Journal of Medicine: NEJM) and one particular "scandal" to make his point that journals' decisions on publication are biased by commercial conflicts of interest (CoIs). It is interesting that he chooses the NEJM which, by his own admission, had one of the strictest CoI policies and had published widely on this topic. The feeling is that if the NEJM can be guilty, they can all be guilty.

  14. The illogicality of stock-brokers: psychological experiments on the effects of prior knowledge and belief biases on logical reasoning in stock trading.

    Science.gov (United States)

    Knauff, Markus; Budeck, Claudia; Wolf, Ann G; Hamburger, Kai

    2010-10-18

    Explanations for the current worldwide financial crisis are primarily provided by economists and politicians. However, in the present work we focus on the psychological-cognitive factors that most likely affect the thinking of people on the economic stage and thus might also have had an effect on the progression of the crises. One of these factors might be the effect of prior beliefs on reasoning and decision-making. So far, this question has been explored only to a limited extent. We report two experiments on logical reasoning competences of nineteen stock-brokers with long-lasting vocational experiences at the stock market. The premises of reasoning problems concerned stock trading and the experiments varied whether or not their conclusions--a proposition which is reached after considering the premises--agreed with the brokers' prior beliefs. Half of the problems had a conclusion that was highly plausible for stock-brokers while the other half had a highly implausible conclusion. The data show a strong belief bias. Stock-brokers were strongly biased by their prior knowledge. Lowest performance was found for inferences in which the problems caused a conflict between logical validity and the experts' belief. In these cases, the stock-brokers tended to make logically invalid inferences rather than give up their existing beliefs. Our findings support the thesis that cognitive factors have an effect on the decision-making on the financial market. In the present study, stock-brokers were guided more by past experience and existing beliefs than by logical thinking and rational decision-making. They had difficulties to disengage themselves from vastly anchored thinking patterns. However, we believe, that it is wrong to accuse the brokers for their "malfunctions", because such hard-wired cognitive principles are difficult to suppress even if the person is aware of them.

  15. The illogicality of stock-brokers: psychological experiments on the effects of prior knowledge and belief biases on logical reasoning in stock trading.

    Directory of Open Access Journals (Sweden)

    Markus Knauff

    Full Text Available BACKGROUND: Explanations for the current worldwide financial crisis are primarily provided by economists and politicians. However, in the present work we focus on the psychological-cognitive factors that most likely affect the thinking of people on the economic stage and thus might also have had an effect on the progression of the crises. One of these factors might be the effect of prior beliefs on reasoning and decision-making. So far, this question has been explored only to a limited extent. METHODS: We report two experiments on logical reasoning competences of nineteen stock-brokers with long-lasting vocational experiences at the stock market. The premises of reasoning problems concerned stock trading and the experiments varied whether or not their conclusions--a proposition which is reached after considering the premises--agreed with the brokers' prior beliefs. Half of the problems had a conclusion that was highly plausible for stock-brokers while the other half had a highly implausible conclusion. RESULTS: The data show a strong belief bias. Stock-brokers were strongly biased by their prior knowledge. Lowest performance was found for inferences in which the problems caused a conflict between logical validity and the experts' belief. In these cases, the stock-brokers tended to make logically invalid inferences rather than give up their existing beliefs. CONCLUSIONS: Our findings support the thesis that cognitive factors have an effect on the decision-making on the financial market. In the present study, stock-brokers were guided more by past experience and existing beliefs than by logical thinking and rational decision-making. They had difficulties to disengage themselves from vastly anchored thinking patterns. However, we believe, that it is wrong to accuse the brokers for their "malfunctions", because such hard-wired cognitive principles are difficult to suppress even if the person is aware of them.

  16. A potential gender bias in assessing quality of life – a standard gamble experiment among university students

    Directory of Open Access Journals (Sweden)

    Al Obaidi L

    2015-04-01

    Full Text Available Leath Al Obaidi,1 Jörg Mahlich2,3 1University of Nottingham, School of Economics, Nottingham, UK; 2Health Economics, Janssen KK, Tokyo, Japan; 3Düsseldorf Institute for Competition Economics (DICE, University of Düsseldorf, Düsseldorf, Germany Background: There are several methodologies that can be used for evaluating patients' perception of their quality of life. Most commonly, utilities are directly elicited by means of either the time-trade-off or the standard-gamble method. In both methods, risk attitudes determine the quality of life values. Methods: Quality of life values among 31 Austrian undergraduate students were elicited by means of the standard gamble approach. The impact of several variables such as gender, side job, length of study, and living arrangements on the quality of life were identified using different types of regression techniques (ordinary least squares, generalized linear model, Betafit. Results: Significant evidence was found that females are associated with a higher quality of life in all specifications of our estimations. Discussion: The observed gender differences in quality of life can be attributed to a higher degree of risk aversion of women. A higher risk aversion leads to a higher valuation of given health states and a potential gender bias in health economic evaluations. This result could have implications for health policy planners when it comes to budget allocation decisions. Keywords: quality of life, gender, risk aversion, standard gamble, students 

  17. Liquid electrode

    Science.gov (United States)

    Ekechukwu, A.A.

    1994-07-05

    A dropping electrolyte electrode is described for use in electrochemical analysis of non-polar sample solutions, such as benzene or cyclohexane. The liquid electrode, preferably an aqueous salt solution immiscible in the sample solution, is introduced into the solution in dropwise fashion from a capillary. The electrolyte is introduced at a known rate, thus, the droplets each have the same volume and surface area. The electrode is used in making standard electrochemical measurements in order to determine properties of non-polar sample solutions. 2 figures.

  18. Cognitive Biases and Nonverbal Cue Availability in Detecting Deception

    Science.gov (United States)

    Burgoon, Judee K.; Blair, J. Pete; Strom, Renee E.

    2008-01-01

    In potentially deceptive situations, people rely on mental shortcuts to help process information. These heuristic judgments are often biased and result in inaccurate assessments of sender veracity. Four such biases--truth bias, visual bias, demeanor bias, and expectancy violation bias--were examined in a judgment experiment that varied nonverbal…

  19. electrode array

    African Journals Online (AJOL)

    PROF EKWUEME

    A geoelectric investigation employing vertical electrical soundings (VES) using the Ajayi - Makinde Two-Electrode array and the ... arrangements used in electrical D.C. resistivity survey. These include ..... Refraction Tomography to Study the.

  20. Biased Supervision

    OpenAIRE

    Josse Delfgaauw; Michiel Souverijn

    2014-01-01

    markdownabstract__Abstract__ When verifiable performance measures are imperfect, organizations often resort to subjective performance pay. This may give supervisors the power to direct employees towards tasks that mainly benefit the supervisor rather than the organization. We cast a principal-supervisor-agent model in a multitask setting, where the supervisor has an intrinsic preference towards specific tasks. We show that subjective performance pay based on evaluation by a biased supervisor ...

  1. Novel corrosion experiments using the wire beam electrode: (III) Measuring electrochemical corrosion parameters from both the metallic and electrolytic phases

    International Nuclear Information System (INIS)

    Tan, Yong-Jun; Liu, Tie; Aung, Naing Naing

    2006-01-01

    The wire beam electrode (WBE) and the scanning reference electrode technique (SRET) have been applied in a novel combination to measure, for the first time, electrochemical parameters simultaneously from both the metallic and electrolytic phases of a corroding metal surface. The objective of this work is to demonstrate the application of this combined WBE-SRET method in obtaining unique information on localised corrosion mechanism, by investigating typical corrosion processes occurring over a mild steel WBE surface exposed to the classic Evans solution. The WBE method was used to map current and potential distributions in the metallic phase, and the SRET was used to map current or potential distribution in the electrolytic phase. It has been found that the combined WBE-SRET method is able to gain useful information on macro-cell electrochemical corrosion processes that involve macro-scale separation of anodes and cathodes. In such macro-cell corrosion systems, maps measured using WBE and SRET were found to correlate with each other and both methods were able to detect the locations of anodic sites. However the movement of the scanning probe during SRET measurements was found to affect the SRET detection of cathodic sites. In micro-cell corrosion systems where the separation of anodic and cathodic sites were less distinct, SRET measurement was found to be insensitive in detecting anodic and cathodic sites, while the WBE method was still able to produce results that correlated well with observed corrosion behaviour. Results obtained from this work suggest that the WBE-SRET method is applicable for understanding the initiation, propagation and electrochemical behaviour of localised corrosion anodes and cathodes, and also their dependence on externally controllable variables, such as solution pH changes and the existence of surface coatings

  2. Avoiding bias effects in NMR experiments for heteronuclear dipole-dipole coupling determinations: principles and application to organic semiconductor materials.

    Science.gov (United States)

    Kurz, Ricardo; Cobo, Marcio Fernando; de Azevedo, Eduardo Ribeiro; Sommer, Michael; Wicklein, André; Thelakkat, Mukundan; Hempel, Günter; Saalwächter, Kay

    2013-09-16

    Carbon-proton dipole-dipole couplings between bonded atoms represent a popular probe of molecular dynamics in soft materials or biomolecules. Their site-resolved determination, for example, by using the popular DIPSHIFT experiment, can be challenged by spectral overlap with nonbonded carbon atoms. The problem can be solved by using very short cross-polarization (CP) contact times, however, the measured modulation curves then deviate strongly from the theoretically predicted shape, which is caused by the dependence of the CP efficiency on the orientation of the CH vector, leading to an anisotropic magnetization distribution even for isotropic samples. Herein, we present a detailed demonstration and explanation of this problem, as well as providing a solution. We combine DIPSHIFT experiments with the rotor-directed exchange of orientations (RODEO) method, and modifications of it, to redistribute the magnetization and obtain undistorted modulation curves. Our strategy is general in that it can also be applied to other types of experiments for heteronuclear dipole-dipole coupling determinations that rely on dipolar polarization transfer. It is demonstrated with perylene-bisimide-based organic semiconductor materials, as an example, in which measurements of dynamic order parameters reveal correlations of the molecular dynamics with the phase structure and functional properties. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Study of Mn dissolution from LiMn{sub 2}O{sub 4} spinel electrodes using rotating ring-disk collection experiments

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Li-Fang; Ou, Chin-Ching; Striebel, Kathryn A.; Chen, Jenn-Shing

    2003-07-01

    The goal of this research was to measure Mn dissolution from a thin porous spinel LiMn{sub 2}O{sub 4} electrode by rotating ring-disk collection experiments. The amount of Mn dissolution from the spinel LiMn{sub 2}O{sub 4} electrode under various conditions was detected by potential step chronoamperometry. The concentration of dissolved Mn was found to increase with increasing cycle numbers and elevated temperature. The dissolved Mn was not dependent on disk rotation speed, which indicated that the Mn dissolution from the disk was under reaction control. The in situ monitoring of Mn dissolution from the spinel was carried out under various conditions. The ring currents exhibited maxima corresponding to the end-of-charge (EOC) and end-of-discharge (EOD), with the largest peak at EOC. The results suggest that the dissolution of Mn from spinel LiMn{sub 2}O{sub 4} occurs during charge/discharge cycling, especially in a charged state (at >4.1 V) and in a discharged state (at <3.1 V). The largest peak at EOC demonstrated that Mn dissolution took place mainly at the top of charge. At elevated temperatures, the ring cathodic currents were larger due to the increase of Mn dissolution rate.

  4. A MEMS-based heating holder for the direct imaging of simultaneous in-situ heating and biasing experiments in scanning/transmission electron microscopes.

    Science.gov (United States)

    Mele, Luigi; Konings, Stan; Dona, Pleun; Evertz, Francis; Mitterbauer, Christoph; Faber, Pybe; Schampers, Ruud; Jinschek, Joerg R

    2016-04-01

    The introduction of scanning/transmission electron microscopes (S/TEM) with sub-Angstrom resolution as well as fast and sensitive detection solutions support direct observation of dynamic phenomena in-situ at the atomic scale. Thereby, in-situ specimen holders play a crucial role: accurate control of the applied in-situ stimulus on the nanostructure combined with the overall system stability to assure atomic resolution are paramount for a successful in-situ S/TEM experiment. For those reasons, MEMS-based TEM sample holders are becoming one of the preferred choices, also enabling a high precision in measurements of the in-situ parameter for more reproducible data. A newly developed MEMS-based microheater is presented in combination with the new NanoEx™-i/v TEM sample holder. The concept is built on a four-point probe temperature measurement approach allowing active, accurate local temperature control as well as calorimetry. In this paper, it is shown that it provides high temperature stability up to 1,300°C with a peak temperature of 1,500°C (also working accurately in gaseous environments), high temperature measurement accuracy (in-situ S/TEM imaging experiments, but also elemental mapping at elevated temperatures using energy-dispersive X-ray spectroscopy (EDS). Moreover, it has the unique capability to enable simultaneous heating and biasing experiments. © 2016 Wiley Periodicals, Inc.

  5. Cermet electrode

    Science.gov (United States)

    Maskalick, Nicholas J.

    1988-08-30

    Disclosed is a cermet electrode consisting of metal particles of nickel, cobalt, iron, or alloys or mixtures thereof immobilized by zirconia stabilized in cubic form which contains discrete deposits of about 0.1 to about 5% by weight of praseodymium, dysprosium, terbium, or a mixture thereof. The solid oxide electrode can be made by covering a substrate with particles of nickel, cobalt, iron, or mixtures thereof, growing a stabilized zirconia solid oxide skeleton around the particles thereby immobilizing them, contacting the skeleton with a compound of praseodymium, dysprosium, terbium, or a mixture thereof, and heating the skeleton to a temperature of at least 500.degree. C. The electrode can also be made by preparing a slurry of nickel, cobalt, iron, or mixture and a compound of praseodymium, dysprosium, terbium, or a mixture thereof, depositing the slurry on a substrate, heating the slurry to dryness, and growing a stabilized zirconia skeleton around the metal particles.

  6. An apparatus for studying electrical breakdown in liquid helium at 0.4 K and testing electrode materials for the neutron electric dipole moment experiment at the Spallation Neutron Source.

    Science.gov (United States)

    Ito, T M; Ramsey, J C; Yao, W; Beck, D H; Cianciolo, V; Clayton, S M; Crawford, C; Currie, S A; Filippone, B W; Griffith, W C; Makela, M; Schmid, R; Seidel, G M; Tang, Z; Wagner, D; Wei, W; Williamson, S E

    2016-04-01

    We have constructed an apparatus to study DC electrical breakdown in liquid helium at temperatures as low as 0.4 K and at pressures between the saturated vapor pressure and ∼600 Torr. The apparatus can house a set of electrodes that are 12 cm in diameter with a gap of 1-2 cm between them, and a potential up to ±50 kV can be applied to each electrode. Initial results demonstrated that it is possible to apply fields exceeding 100 kV/cm in a 1 cm gap between two electropolished stainless steel electrodes 12 cm in diameter for a wide range of pressures at 0.4 K. We also measured the current between two electrodes. Our initial results, I 5 × 10(18) Ω cm. This lower bound is 5 times larger than the bound previously measured. We report the design, construction, and operational experience of the apparatus, as well as initial results.

  7. Ion-selective electrodes

    Energy Technology Data Exchange (ETDEWEB)

    Mikhelson, Konstantin N. [St. Petersburg State Univ. (Russian Federation). Ion-Selective Electrode Laboratory

    2013-06-01

    Ion-selective electrodes (ISEs) have a wide range of applications in clinical, environmental, food and pharmaceutical analysis as well as further uses in chemistry and life sciences. Based on his profound experience as a researcher in ISEs and a course instructor, the author summarizes current knowledge for advanced teaching and training purposes with a particular focus on ionophore-based ISEs. Coverage includes the basics of measuring with ISEs, essential membrane potential theory and a comprehensive overview of the various classes of ion-selective electrodes. The principles of constructing ISEs are outlined, and the transfer of methods into routine analysis is considered.

  8. Ion-selective electrodes

    CERN Document Server

    Mikhelson, Konstantin N

    2013-01-01

    Ion-selective electrodes (ISEs) have a wide range of applications in clinical, environmental, food and pharmaceutical analysis as well as further uses in chemistry and life sciences. Based on his profound experience as a researcher in ISEs and a course instructor, the author summarizes current knowledge for advanced teaching and training purposes with a particular focus on ionophore-based ISEs. Coverage includes the basics of measuring with ISEs, essential membrane potential theory and a comprehensive overview of the various classes of ion-selective electrodes. The principles of constructing I

  9. What happens before? A field experiment exploring how pay and representation differentially shape bias on the pathway into organizations.

    Science.gov (United States)

    Milkman, Katherine L; Akinola, Modupe; Chugh, Dolly

    2015-11-01

    Little is known about how discrimination manifests before individuals formally apply to organizations or how it varies within and between organizations. We address this knowledge gap through an audit study in academia of over 6,500 professors at top U.S. universities drawn from 89 disciplines and 259 institutions. In our experiment, professors were contacted by fictional prospective students seeking to discuss research opportunities prior to applying to a doctoral program. Names of students were randomly assigned to signal gender and race (White, Black, Hispanic, Indian, Chinese), but messages were otherwise identical. We hypothesized that discrimination would appear at the informal "pathway" preceding entry to academia and would vary by discipline and university as a function of faculty representation and pay. We found that when considering requests from prospective students seeking mentoring in the future, faculty were significantly more responsive to White males than to all other categories of students, collectively, particularly in higher-paying disciplines and private institutions. Counterintuitively, the representation of women and minorities and discrimination were uncorrelated, a finding that suggests greater representation cannot be assumed to reduce discrimination. This research highlights the importance of studying decisions made before formal entry points into organizations and reveals that discrimination is not evenly distributed within and between organizations. (c) 2015 APA, all rights reserved).

  10. Magnetohydrodynamic electrode

    International Nuclear Information System (INIS)

    1980-01-01

    The object of the invention is the provision of a material capable of withstanding a high-temperature, corrosive and erosive environment for use as a ceramic-metal composite electrode current collector in the channel of a magnetohydrodynamic generator. (U.K.)

  11. Microbial electrode sensor for alcohols

    Energy Technology Data Exchange (ETDEWEB)

    Hikuma, M [Ajinomoto Co., Inc., Kawasaki, Japan; Kubo, T; Yasuda, T; Karube, I; Suzuki, S

    1979-10-01

    A microbial electrode consisting of immobilized microorganisms, a gas permeable Teflon membrane, and an oxygen electrode was prepared for the continuous determination of methyl and ethyl alcohols. Immobilized Trichosporon brassicae was employed for a microbial electrode sensor for ethyl alcohol. When a sample solution containing ethyl alcohol was injected into a microbial electrode system, the current of the electrode decreased markedly with time until a steady state was reached. The response time was within 10 min by the steady state method and within 6 min by the pulse method. A linear relationship was observed between the current decrease and the concentration of ethyl alcohol below 22.5 mg/liter. The current was reproducible within +- 6% of the relative error when a sample solution containing 16.5 mg/liter ethyl alcohol. The standard deviation was 0.5 mg/liter in 40 experiments. The selectivity of the microbial electrode sensor for ethyl alcohol was satisfactory. The microbial electrode sensor was applied to a fermentation broth of yeasts and satisfactory comparative results were obtained (correlation coefficient 0.98). The current output of the microbial electrode sensor was almost constant for more than three weeks and 2100 assays. A microbial electrode sensor using immobilized bacteria for methyl alcohol was also described.

  12. Photoelectrocatalytic property of microporous Pt-TiO2/Ti electrodes

    International Nuclear Information System (INIS)

    Hung, Chung-Hsuang; Wu, Kee-Rong; Yeh, Chung-Wei; Sun, Jui-Ching; Hsu, Chuan-Jen

    2013-01-01

    This study investigates the photoelectrocatalytic (PEC) property of microporous WO 3 -loaded TiO 2 /Ti layer, prepared via micro-arc oxidation (MAO) of Ti plate, followed by sputtering deposition of a thin Pt layer as a Pt-TiO 2 /Ti electrode. The WO 3 -loaded TiO 2 layer which is associated with a more acidic surface forms many local electrochemical cells on its micro-pores immersed in cationic dye solution. The electrocatalytic (EC) reactions can take place in the local cells by the applied electrons. A low resistivity that is accomplished by MAO technique and by platinization offers an easy path for the electron motions in the Pt-TiO 2 /Ti electrode. All these features make the EC oxidation of aqueous dye pollutants practically feasible without using counter electrodes and supporting electrolytes. Our experiments demonstrate that, under PEC condition, the Pt-TiO 2 /Ti shows the highest degradation rate constant of 0.83 h − 1 at an applied bias of 1.0 V and exhibits significantly high PEC and EC oxidation activities at a low applied bias of 0.25 V. This is attributable to high anodic currents generated in the Pt-TiO 2 /Ti even at low bias. The modified microporous electrodes conclusively reveal a very interesting EC property as a two double-sided device that functions the PEC and EC oxidation simultaneously without a need of supporting electrolyte and expensive Pt cathode. - Highlights: ► Pt-TiO 2 /Ti exhibits enhanced photoelectrocatalytic (PEC) activity at low applied bias. ► The proposed device uses low applied bias (< 1.0 V) with no explicit cathode. ► PEC oxidation can be performed without supporting electrolyte and Pt cathode

  13. Electrode Processes in Porous Electrodes.

    Science.gov (United States)

    1985-11-26

    F104470 2.0 MASS SPECTROMETRY One part of activity for this year is an investigation of the behavior of silver electrodes through the distribution of...al. (2)). These, in some cases, involve tedious and time comsuming procedures and discrepencies of as much as 15% have been observed in the results. As

  14. Light addressable gold electrodes

    Energy Technology Data Exchange (ETDEWEB)

    Khalid, Waqas

    2011-07-01

    The main objective carried out in this dissertation was to fabricate Light Amplified Potentiometric sensors (LAPS) based upon the semiconductor nanoparticles (quantum dots) instead of its bulk form. Quantum dots (QDs) were opted for this device fabrication because of their superior fluorescent, electric and catalytic properties. Also in comparison to their bulk counterparts they will make device small, light weighted and power consumption is much lower. QDs were immobilized on a Au substrate via 1,4 benzene dithiol (BDT) molecule. Initially a self-assembled monolayer (SAM) of BDT was established on Au substrate. Because of SAM, the conductivity of Au substrate decreased dramatically. Furthermore QDs were anchored with the help of BDT molecule on Au substrate. When QDs immobilized on Au substrate (QD/Au) via BDT molecule were irradiated with UV-visible light, electron-hole pairs were generated in QDs. The surface defect states in QDs trapped the excited electrons and long lived electron-hole pairs were formed. By the application of an appropriate bias potential on Au substrate the electrons could be supplied or extracted from the QDs via tunneling through BDT. Thus a cathodic or anodic current could be observed depending upon bias potential under illumination. However without light illumination the QD/Au electrode remained an insulator. To improve the device different modifications were made, including different substrates (Au evaporated on glass, Au evaporated on mica sheets and Au sputtered on SiO{sub 2}/Si) and different dithiol molecules (capped and uncapped biphenyl 4,4' dithiol and capped and uncapped 4,4' dimercaptostilbenes) were tried. Also different QD immobilization techniques (normal incubation, spin coating, layer by layer assembly (LbL) of polyelectrolytes and heat immobilization) were employed. This device was able to detect electrochemically different analytes depending upon the QDs incorporated. For example CdS QDs were able to detect 4

  15. The cultivation bias: different communities of arbuscular mycorrhizal fungi detected in roots from the field, from bait plants transplanted to the field, and from a greenhouse trap experiment.

    Science.gov (United States)

    Sýkorová, Zuzana; Ineichen, Kurt; Wiemken, Andres; Redecker, Dirk

    2007-12-01

    The community composition of arbuscular mycorrhizal fungi (AMF) was investigated in roots of four different plant species (Inula salicina, Medicago sativa, Origanum vulgare, and Bromus erectus) sampled in (1) a plant species-rich calcareous grassland, (2) a bait plant bioassay conducted directly in that grassland, and (3) a greenhouse trap experiment using soil and a transplanted whole plant from that grassland as inoculum. Roots were analyzed by AMF-specific nested polymerase chain reaction, restriction fragment length polymorphism screening, and sequence analyses of rDNA small subunit and internal transcribed spacer regions. The AMF sequences were analyzed phylogenetically and used to define monophyletic phylotypes. Overall, 16 phylotypes from several lineages of AMF were detected. The community composition was strongly influenced by the experimental approach, with additional influence of cultivation duration, substrate, and host plant species in some experiments. Some fungal phylotypes, e.g., GLOM-A3 (Glomus mosseae) and several members of Glomus group B, appeared predominantly in the greenhouse experiment or in bait plants. Thus, these phylotypes can be considered r strategists, rapidly colonizing uncolonized ruderal habitats in early successional stages of the fungal community. In the greenhouse experiment, for instance, G. mosseae was abundant after 3 months, but could not be detected anymore after 10 months. In contrast, other phylotypes as GLOM-A17 (G. badium) and GLOM-A16 were detected almost exclusively in roots sampled from plants naturally growing in the grassland or from bait plants exposed in the field, indicating that they preferentially occur in late successional stages of fungal communities and thus represent the K strategy. The only phylotype found with high frequency in all three experimental approaches was GLOM A-1 (G. intraradices), which is known to be a generalist. These results indicate that, in greenhouse trap experiments, it is difficult

  16. First Step to Understand Intergroup Bias and Cohesion from the One World Experiment: A Pilot Project to Evaluate the Effect of the 'Pale Blue Dot' Hypothesis

    Science.gov (United States)

    Fukushima, K.; Venugopal, R.

    2018-02-01

    The One World Experiment was carried out as a pilot effort in Cape Town, South Africa, to test whether exposure to an astronomy intervention affects empathy and altruism in children. The intervention focused on introducing children to knowledge around the Earth's position in the Universe and collecting data to assess the effect. This paper presents the project background as well as the methodology and results from the project's first phase, designed to understand the possible difference in empathetic response between a child and other 'ingroup' and 'outgroup' children; for any child, an 'ingroup' child is one belonging to their own social group (in this case, nationality), and an 'outgroup' child is one belonging to a social group other than their own. It is found that the students across the study have a strong cohesion to those of the same nationality but that there is no nationality bias in their feelings towards how other children share their joy with them. Full analysis of the data, which will compare the control group and experimental group results and focuses on the impact of astronomy intervention, is underway for future publication.

  17. Bias against research on gender bias.

    Science.gov (United States)

    Cislak, Aleksandra; Formanowicz, Magdalena; Saguy, Tamar

    2018-01-01

    The bias against women in academia is a documented phenomenon that has had detrimental consequences, not only for women, but also for the quality of science. First, gender bias in academia affects female scientists, resulting in their underrepresentation in academic institutions, particularly in higher ranks. The second type of gender bias in science relates to some findings applying only to male participants, which produces biased knowledge. Here, we identify a third potentially powerful source of gender bias in academia: the bias against research on gender bias. In a bibliometric investigation covering a broad range of social sciences, we analyzed published articles on gender bias and race bias and established that articles on gender bias are funded less often and published in journals with a lower Impact Factor than articles on comparable instances of social discrimination. This result suggests the possibility of an underappreciation of the phenomenon of gender bias and related research within the academic community. Addressing this meta-bias is crucial for the further examination of gender inequality, which severely affects many women across the world.

  18. Elements of a pragmatic approach for dealing with bias and uncertainty in experiments through predictions : experiment design and data conditioning; %22real space%22 model validation and conditioning; hierarchical modeling and extrapolative prediction.

    Energy Technology Data Exchange (ETDEWEB)

    Romero, Vicente Jose

    2011-11-01

    This report explores some important considerations in devising a practical and consistent framework and methodology for utilizing experiments and experimental data to support modeling and prediction. A pragmatic and versatile 'Real Space' approach is outlined for confronting experimental and modeling bias and uncertainty to mitigate risk in modeling and prediction. The elements of experiment design and data analysis, data conditioning, model conditioning, model validation, hierarchical modeling, and extrapolative prediction under uncertainty are examined. An appreciation can be gained for the constraints and difficulties at play in devising a viable end-to-end methodology. Rationale is given for the various choices underlying the Real Space end-to-end approach. The approach adopts and refines some elements and constructs from the literature and adds pivotal new elements and constructs. Crucially, the approach reflects a pragmatism and versatility derived from working many industrial-scale problems involving complex physics and constitutive models, steady-state and time-varying nonlinear behavior and boundary conditions, and various types of uncertainty in experiments and models. The framework benefits from a broad exposure to integrated experimental and modeling activities in the areas of heat transfer, solid and structural mechanics, irradiated electronics, and combustion in fluids and solids.

  19. Determination and Correction of Persistent Biases in Quantum Annealers

    Science.gov (United States)

    2016-08-25

    for all of the qubits. Narrowing of the bias distribution. To show the correctability of the persistent biases , we ran the experiment described above...this is a promising application for bias correction . Importantly, while the J biases determined here are in general smaller than the h biases , numerical...1Scientific RepoRts | 6:18628 | DOI: 10.1038/srep18628 www.nature.com/scientificreports Determination and correction of persistent biases in quantum

  20. Insulating electrodes: a review on biopotential front ends for dielectric skin–electrode interfaces

    International Nuclear Information System (INIS)

    Spinelli, Enrique; Haberman, Marcelo

    2010-01-01

    Insulating electrodes, also known as capacitive electrodes, allow acquiring biopotentials without galvanic contact with the body. They operate with displacement currents instead of real charge currents, and the electrolytic electrode–skin interface is replaced by a dielectric film. The use of insulating electrodes is not the end of electrode interface problems but the beginning of new ones: coupling capacitances are of the order of pF calling for ultra-high input impedance amplifiers and careful biasing, guarding and shielding techniques. In this work, the general requirements of front ends for capacitive electrodes are presented and the different contributions to the overall noise are discussed and estimated. This analysis yields that noise bounds depend on features of the available devices as current and voltage noise, but the final noise level also depends on parasitic capacitances, requiring a careful shield and printed circuit design. When the dielectric layer is placed on the skin, the present-day amplifiers allow achieving noise levels similar to those provided by wet electrodes. Furthermore, capacitive electrode technology allows acquiring high quality ECG signals through thin clothes. A prototype front end for capacitive electrodes was built and tested. ECG signals were acquired with these electrodes in direct contact with the skin and also through cotton clothes 350 µm thick. They were compared with simultaneously acquired signals by means of wet electrodes and no significant differences were observed between both output signals

  1. An electrode polarization impedance based flow sensor for low water flow measurement

    International Nuclear Information System (INIS)

    Yan, Tinghu; Sabic, Darko

    2013-01-01

    This note describes an electrode polarization impedance based flow sensor for low water flow measurement. It consists of two pairs of stainless steel electrodes set apart and inserted into a non-conductive flow tube with each pair of electrodes placed diametrically at the opposite sides. The flow sensor is modeled as a typical four-electrode system of which two electrodes are current-carrying and the other two serve as output pick ups. The polarization impedances of the two current carrying electrodes are affected by water flows resulting in changes of differential potential between the two pick-up electrodes which are separated by the same fluid. The interrogation of the two excitation electrodes with dc biased ac signals offers significantly higher sensor sensitivities to flow. The prototype flow sensor constructed for a 20 mm diameter pipeline was able to measure water flow rate as low as tested at 1.06 l h −1 and remained sensitive at a flow rate of 25.18 l h −1 when it was driven with a sinusoidal voltage at 1000 Hz with a peak ac amplitude of 2 V and a dc offset of +8 V. The nonlinear characteristics of the sensor response indicate that the sensor is more sensitive at low flows and will not be able to measure at very high flows. Additional experiments are needed to evaluate the influences of impurities, chemical species, ions constituents, conductivity and temperature over a practical range of residential water conditions, the effects of fluctuating ground signals, measurement uncertainty, power consumption, compensation of effects and practical operations. The flow sensor (principle) presented may be used as (in) a secondary sensor in combination with an existing electronic water meter to extend the low end of measurement range in residential water metering. (technical design note)

  2. Junction Potentials Bias Measurements of Ion Exchange Membrane Permselectivity.

    Science.gov (United States)

    Kingsbury, Ryan S; Flotron, Sophie; Zhu, Shan; Call, Douglas F; Coronell, Orlando

    2018-04-17

    Ion exchange membranes (IEMs) are versatile materials relevant to a variety of water and waste treatment, energy production, and industrial separation processes. The defining characteristic of IEMs is their ability to selectively allow positive or negative ions to permeate, which is referred to as permselectivity. Measured values of permselectivity that equal unity (corresponding to a perfectly selective membrane) or exceed unity (theoretically impossible) have been reported for cation exchange membranes (CEMs). Such nonphysical results call into question our ability to correctly measure this crucial membrane property. Because weighing errors, temperature, and measurement uncertainty have been shown to not explain these anomalous permselectivity results, we hypothesized that a possible explanation are junction potentials that occur at the tips of reference electrodes. In this work, we tested this hypothesis by comparing permselectivity values obtained from bare Ag/AgCl wire electrodes (which have no junction) to values obtained from single-junction reference electrodes containing two different electrolytes. We show that permselectivity values obtained using reference electrodes with junctions were greater than unity for CEMs. In contrast, electrodes without junctions always produced permselectivities lower than unity. Electrodes with junctions also resulted in artificially low permselectivity values for AEMs compared to electrodes without junctions. Thus, we conclude that junctions in reference electrodes introduce two biases into results in the IEM literature: (i) permselectivity values larger than unity for CEMs and (ii) lower permselectivity values for AEMs compared to those for CEMs. These biases can be avoided by using electrodes without a junction.

  3. Study of new germanium bolometers with interleaved concentric electrodes for non-baryonic cold dark matter direct detection in the Edelweiss-II experiment

    International Nuclear Information System (INIS)

    Domange, J.

    2011-09-01

    EDELWEISS is a direct non-baryonic cold dark matter detection experiment in the form of weakly interacting massive particles (also known as WIMPs), which currently constitute the most popular candidates to account for the missing mass in the Universe. To this purpose, EDELWEISS uses germanium bolometers at cryogenic temperature (20 mK approximately) in the Underground Laboratory of Modane (LSM) at the French-Italian border. Since 2008, a new type of detector is operated, equipped with concentric electrodes to optimize the rejection of surface events (coplanar-grid detectors). This thesis work is divided into several research orientations. First, we carried out measurements concerning charge collection in the crystals. The velocity laws of the carriers (electrons and holes) have been determined in germanium at 20 mK in the orientation, and a complete study of charge sharing has been done, including an evaluation of the transport anisotropy and of the straggling of the carriers. These results lead to a better understanding of the inner properties of the EDELWEISS detectors. Then, studies relating to the improvement of the performances were carried out. In particular, we have optimized the space-charge cancellation procedure in the crystals and improved the passive rejection of surface events (β). The fiducial volume of the detectors has been evaluated using two X-ray lines from cosmically activated radionuclides: 68 Ge and 65 Zn. Finally, an exhaustive study of the low energy spectra has been carried out, which makes it possible to develop a systematic analysis method for the search of low-mass WIMPs in EDELWEISS. (author)

  4. An apparatus for studying electrical breakdown in liquid helium at 0.4 K and testing electrode materials for the neutron electric dipole moment experiment at the Spallation Neutron Source

    Energy Technology Data Exchange (ETDEWEB)

    Ito, T. M., E-mail: ito@lanl.gov; Ramsey, J. C.; Clayton, S. M.; Currie, S. A.; Griffith, W. C.; Makela, M.; Tang, Z.; Wei, W. [Los Alamos National Laboratory, Los Alamos, New Mexico 87545 (United States); Yao, W.; Cianciolo, V. [Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831 (United States); Beck, D. H.; Williamson, S. E. [Loomis Laboratory of Physics, University of Illinois, Urbana, Illinois 61801 (United States); Crawford, C.; Wagner, D. [Department of Physics and Astronomy, University of Kentucky, Lexington, Kentucky 40506 (United States); Filippone, B. W.; Schmid, R. [W. K. Kellogg Radiation Laboratory, California Institute of Technology, Pasadena, California 91125 (United States); Seidel, G. M. [Department of Physics, Brown University, Providence, Rhode Island 02912 (United States)

    2016-04-15

    We have constructed an apparatus to study DC electrical breakdown in liquid helium at temperatures as low as 0.4 K and at pressures between the saturated vapor pressure and ∼600 Torr. The apparatus can house a set of electrodes that are 12 cm in diameter with a gap of 1–2 cm between them, and a potential up to ±50 kV can be applied to each electrode. Initial results demonstrated that it is possible to apply fields exceeding 100 kV/cm in a 1 cm gap between two electropolished stainless steel electrodes 12 cm in diameter for a wide range of pressures at 0.4 K. We also measured the current between two electrodes. Our initial results, I < 1 pA at 45 kV, correspond to a lower bound on the effective volume resistivity of liquid helium of ρ{sub V} > 5 × 10{sup 18} Ω cm. This lower bound is 5 times larger than the bound previously measured. We report the design, construction, and operational experience of the apparatus, as well as initial results.

  5. Combination of biased forecasts: Bias correction or bias based weights?

    OpenAIRE

    Wenzel, Thomas

    1999-01-01

    Most of the literature on combination of forecasts deals with the assumption of unbiased individual forecasts. Here, we consider the case of biased forecasts and discuss two different combination techniques resulting in an unbiased forecast. On the one hand we correct the individual forecasts, and on the other we calculate bias based weights. A simulation study gives some insight in the situations where we should use the different methods.

  6. On the relative independence of thinking biases and cognitive ability.

    Science.gov (United States)

    Stanovich, Keith E; West, Richard F

    2008-04-01

    In 7 different studies, the authors observed that a large number of thinking biases are uncorrelated with cognitive ability. These thinking biases include some of the most classic and well-studied biases in the heuristics and biases literature, including the conjunction effect, framing effects, anchoring effects, outcome bias, base-rate neglect, "less is more" effects, affect biases, omission bias, myside bias, sunk-cost effect, and certainty effects that violate the axioms of expected utility theory. In a further experiment, the authors nonetheless showed that cognitive ability does correlate with the tendency to avoid some rational thinking biases, specifically the tendency to display denominator neglect, probability matching rather than maximizing, belief bias, and matching bias on the 4-card selection task. The authors present a framework for predicting when cognitive ability will and will not correlate with a rational thinking tendency. (c) 2008 APA, all rights reserved.

  7. Benefits of being biased!

    Indian Academy of Sciences (India)

    Administrator

    Journal of Genetics, Vol. 83, No. 2, August 2004. Keywords. codon bias; alcohol dehydrogenase; Darwinian ... RESEARCH COMMENTARY. Benefits of being biased! SUTIRTH DEY*. Evolutionary Biology Laboratory, Evolutionary & Organismal Biology Unit,. Jawaharlal Nehru Centre for Advanced Scientific Research,.

  8. HVDC Ground Electrodes and Tectonic Setting

    Science.gov (United States)

    Freire, P. F.; Pereira, S. Y.

    2017-12-01

    Ground electrodes in HVDC transmission are huge grounding systems for the DC part of the converter substation, about 1 km wide, sized to inject in the ground DC currents up to 3.5 kA. This work presents an analysis of how the tectonic setting at converter substation location is determinant for the search of the best electrode location (Site Selection) and on its design and performance. It will briefly present the author experience on HVDC electrode design, summarized as follows: Itaipu - Foz do Iguaçu electrodes (transmitter side) located in the middle of Paraná Sedimentary Basin, and Ibiúna electrodes (receiving side) on the border of the basin, 6 km from the geological strike, where the crystalline basement outcrops in São Paulo state; Madeira River - North electrodes (transmitting side) located on the Northwest border of South Amazon Craton, where the crystalline basement is below a shallow sediments layer, and South electrodes (receiving side) located within Paraná Sedimentary Basin; Chile - electrodes located on the Andean forearc, where the Nazca Plate plunges under the South American Plate; Kenya - Ethiopia - electrodes located in the African Rift; Belo Monte - North electrodes (transmitter side) located within the Amazonian Sedimentary Basin, about 35 km of its South border, and South electrodes (receiving side) within Paraná Sedimentary Basin (bipole 1) and on crystalline metamorphic terrain "Brasília Belt" (bipole 2). This diversity of geological conditions results on ground electrodes of different topologies and dimensions, with quite different electrical and thermal performances. A brief study of the geology of the converter stations regions, the so-called Desktop Study, allows for the preview of several important parameters for the site selection and design of the electrodes, such as localization, type, size and estimate of the interference area, which are important predictors of the investment to be made and indications of the design to be

  9. Cognitive biases and decision making in gambling.

    Science.gov (United States)

    Chóliz, Mariano

    2010-08-01

    Heuristics and cognitive biases can occur in reasoning and decision making. Some of them are very common in gamblers (illusion of control, representativeness, availability, etc.). Structural characteristics and functioning of games of chance favor the appearance of these biases. Two experiments were conducted with nonpathological gamblers. The first experiment was a game of dice with wagers. In the second experiment, the participants played two bingo games. Specific rules of the games favored the appearance of cognitive bias (illusion of control) and heuristics (representativeness and availability) and influence on the bets. Results and implications for gambling are discussed.

  10. Polymeric electrodes

    Science.gov (United States)

    Appel, G.; Mikalo, R.; Henkel, K.; Oprea, A.; Yfantis, A.; Paloumpa, I.; Schmeißer, D.

    2000-05-01

    We report experiments on conducting polymer polypyrrole leading to sensor applications. The resonance frequency, stability and sensitivity of AT-cut quartz crystals, electrochemically covered with polypyrrole tosylate, were tested under various operating conditions. The interaction of this organic semiconductor with thin metallic films was analysed by photoelectron investigations. Shifts of the valence band spectra during silver deposition are explained by the neutralization of positive charged surface defects. Thus the existence of a space charge region in polypyrrole is demonstrated spectroscopically.

  11. Biased lineups: sequential presentation reduces the problem.

    Science.gov (United States)

    Lindsay, R C; Lea, J A; Nosworthy, G J; Fulford, J A; Hector, J; LeVan, V; Seabrook, C

    1991-12-01

    Biased lineups have been shown to increase significantly false, but not correct, identification rates (Lindsay, Wallbridge, & Drennan, 1987; Lindsay & Wells, 1980; Malpass & Devine, 1981). Lindsay and Wells (1985) found that sequential lineup presentation reduced false identification rates, presumably by reducing reliance on relative judgment processes. Five staged-crime experiments were conducted to examine the effect of lineup biases and sequential presentation on eyewitness recognition accuracy. Sequential lineup presentation significantly reduced false identification rates from fair lineups as well as from lineups biased with regard to foil similarity, instructions, or witness attire, and from lineups biased in all of these ways. The results support recommendations that police present lineups sequentially.

  12. Multi electrode semiconductors detectors

    CERN Document Server

    Amendolia, S R; Bertolucci, Ennio; Bosisio, L; Bradaschia, C; Budinich, M; Fidecaro, F; Foà, L; Focardi, E; Giazotto, A; Giorgi, M A; Marrocchesi, P S; Menzione, A; Ristori, L; Rolandi, Luigi; Scribano, A; Stefanini, A; Vincelli, M L

    1981-01-01

    Detectors with very high space resolution have been built in this laboratory and tested at CERN in order to investigate their possible use in high energy physics experiments. These detectors consist of thin layers of silicon crystals acting as ionization chambers. Thin electrodes, structured in strips or in more fancy shapes are applied to their surfaces by metal coating. The space resolution which could be reached is of the order of a few microns. An interesting feature of these solid state detectors is that they can work under very high or low external pressure or at very low temperature. The use of these detectors would strongly reduce the dimensions and the cost of high energy experiments. (3 refs).

  13. Multi electrode semiconductor detectors

    International Nuclear Information System (INIS)

    Amendolia, S.R.; Batignani, G.; Bertolucci, E.; Bosisio, L.; Budinich, M.; Bradaschia, C.; Fidecaro, F.; Foa, L.; Focardi, E.; Giazotto, A.; Giorgi, M.A.; Marrocchesi, P.S.; Menzione, A.; Ristori, L.; Rolandi, L.; Scribano, A.; Stefanini, A.; Vincelli, M.L.

    1981-01-01

    Detectors with very high space resolution have been built in the laboratory and tested at CERN in order to investigate their possible use in high energy physics experiments. These detectors consist of thin layers of silicon crystals acting as ionization chambers. Thin electrodes, structured in strips or in more fancy shapes are applied to their surfaces by metal coating. The space resolution which could be reached is of the order of a few microns. An interesting feature of these solid state detectors is that they can work under very high or low external pressure or at very low temperature. The use of these detectors would strongly reduce the dimensions and the cost of high energy experiments. (Auth.)

  14. Numerical value biases sound localization.

    Science.gov (United States)

    Golob, Edward J; Lewald, Jörg; Getzmann, Stephan; Mock, Jeffrey R

    2017-12-08

    Speech recognition starts with representations of basic acoustic perceptual features and ends by categorizing the sound based on long-term memory for word meaning. However, little is known about whether the reverse pattern of lexical influences on basic perception can occur. We tested for a lexical influence on auditory spatial perception by having subjects make spatial judgments of number stimuli. Four experiments used pointing or left/right 2-alternative forced choice tasks to examine perceptual judgments of sound location as a function of digit magnitude (1-9). The main finding was that for stimuli presented near the median plane there was a linear left-to-right bias for localizing smaller-to-larger numbers. At lateral locations there was a central-eccentric location bias in the pointing task, and either a bias restricted to the smaller numbers (left side) or no significant number bias (right side). Prior number location also biased subsequent number judgments towards the opposite side. Findings support a lexical influence on auditory spatial perception, with a linear mapping near midline and more complex relations at lateral locations. Results may reflect coding of dedicated spatial channels, with two representing lateral positions in each hemispace, and the midline area represented by either their overlap or a separate third channel.

  15. High performance cermet electrodes

    Science.gov (United States)

    Isenberg, Arnold O.; Zymboly, Gregory E.

    1986-01-01

    Disclosed is a method of increasing the operating cell voltage of a solid oxide electrochemical cell having metal electrode particles in contact with an oxygen-transporting ceramic electrolyte. The metal electrode is heated with the cell, and oxygen is passed through the oxygen-transporting ceramic electrolyte to the surface of the metal electrode particles so that the metal electrode particles are oxidized to form a metal oxide layer between the metal electrode particles and the electrolyte. The metal oxide layer is then reduced to form porous metal between the metal electrode particles and the ceramic electrolyte.

  16. Probing Biased Signaling in Chemokine Receptors

    DEFF Research Database (Denmark)

    Amarandi, Roxana Maria; Hjortø, Gertrud Malene; Rosenkilde, Mette Marie

    2016-01-01

    The chemokine system mediates leukocyte migration during homeostatic and inflammatory processes. Traditionally, it is described as redundant and promiscuous, with a single chemokine ligand binding to different receptors and a single receptor having several ligands. Signaling of chemokine receptors...... of others has been termed signaling bias and can accordingly be grouped into ligand bias, receptor bias, and tissue bias. Bias has so far been broadly overlooked in the process of drug development. The low number of currently approved drugs targeting the chemokine system, as well as the broad range...... of failed clinical trials, reflects the need for a better understanding of the chemokine system. Thus, understanding the character, direction, and consequence of biased signaling in the chemokine system may aid the development of new therapeutics. This review describes experiments to assess G protein...

  17. Cobalt phthalocyanine modified electrodes utilised in electroanalysis: nano-structured modified electrodes vs. bulk modified screen-printed electrodes.

    Science.gov (United States)

    Foster, Christopher W; Pillay, Jeseelan; Metters, Jonathan P; Banks, Craig E

    2014-11-19

    Cobalt phthalocyanine (CoPC) compounds have been reported to provide electrocatalytic performances towards a substantial number of analytes. In these configurations, electrodes are typically constructed via drop casting the CoPC onto a supporting electrode substrate, while in other cases the CoPC complex is incorporated within the ink of a screen-printed sensor, providing a one-shot economical and disposable electrode configuration. In this paper we critically compare CoPC modified electrodes prepared by drop casting CoPC nanoparticles (nano-CoPC) onto a range of carbon based electrode substrates with that of CoPC bulk modified screen-printed electrodes in the sensing of the model analytes L-ascorbic acid, oxygen and hydrazine. It is found that no "electrocatalysis" is observed towards L-ascorbic acid using either of these CoPC modified electrode configurations and that the bare underlying carbon electrode is the origin of the obtained voltammetric signal, which gives rise to useful electroanalytical signatures, providing new insights into literature reports where "electrocatalysis" has been reported with no clear control experiments undertaken. On the other hand true electrocatalysis is observed towards hydrazine, where no such voltammetric features are witnessed on the bare underlying electrode substrate.

  18. Cobalt Phthalocyanine Modified Electrodes Utilised in Electroanalysis: Nano-Structured Modified Electrodes vs. Bulk Modified Screen-Printed Electrodes

    Directory of Open Access Journals (Sweden)

    Christopher W. Foster

    2014-11-01

    Full Text Available Cobalt phthalocyanine (CoPC compounds have been reported to provide electrocatalytic performances towards a substantial number of analytes. In these configurations, electrodes are typically constructed via drop casting the CoPC onto a supporting electrode substrate, while in other cases the CoPC complex is incorporated within the ink of a screen-printed sensor, providing a one-shot economical and disposable electrode configuration. In this paper we critically compare CoPC modified electrodes prepared by drop casting CoPC nanoparticles (nano-CoPC onto a range of carbon based electrode substrates with that of CoPC bulk modified screen-printed electrodes in the sensing of the model analytes L-ascorbic acid, oxygen and hydrazine. It is found that no “electrocatalysis” is observed towards L-ascorbic acid using either of these CoPC modified electrode configurations and that the bare underlying carbon electrode is the origin of the obtained voltammetric signal, which gives rise to useful electroanalytical signatures, providing new insights into literature reports where “electrocatalysis” has been reported with no clear control experiments undertaken. On the other hand true electrocatalysis is observed towards hydrazine, where no such voltammetric features are witnessed on the bare underlying electrode substrate.

  19. RETGEM with polyvinylchloride (PVC) electrodes

    CERN Document Server

    Razin, V I; Reshetin, A I; Filippov, S N

    2009-01-01

    This paper presents a new design of the RETGEM (Resistive Electrode Thick GEM) based on electrodes made of a polyvinylchloride material (PVC). Our device can operate with gains of 10E5 as a conventional TGEM at low counting rates and as RPC in the case of high counting rates without of the transit to the violent sparks. The distinct feature of present RETGEM is the absent of the metal coating and lithographic technology for manufacturing of the protective dielectric rms. The electrodes from PVC permit to do the holes by a simple drilling machine. Detectors on a RETGEM basis could be useful in many fields of an application requiring a more cheap manufacturing and safe operation, for example, in a large neutrino experiments, in TPC, RICH systems.

  20. TCABR Tokamak scrape-off layer turbulence with DC biasing

    International Nuclear Information System (INIS)

    Heller, M.V.A.P.; Ferreira, A.A.; Caldas, I.L.; Nascimento, I.C.

    2004-01-01

    Turbulence and particle transport in plasma scrape-off layer have been controlled by external electric fields. This control can be achieved by a biasing electrode located inside the plasma. We investigate plasma turbulence changes in the scrape-off layer of TCABR tokamak introduced by DC biasing an electrode inside the plasma. Our investigation is based on the alterations observed on the wavelet power spectra and on the intermittent burst sequences of plasma potential and density fluctuations measured by a set of Langmuir probes. Biasing the electrode changes the turbulence statistics and the bursts intermittence. With the imposed external electric field, fluctuation amplitudes, phase velocities, and anomalous particle transport are modified. Transport reduction for higher frequencies induced by the biasing could be due to the strong de-phasing between density and potential fluctuations. The mode coupling increases with the perturbation for the high frequency broadband fluctuations. The total (laminar and bursting) radial particle transport is reduced by about 25% by DC biasing. Bursts contribution to total transport is 15% and for the studied conditions this contribution does not change much with the bias perturbation

  1. The Electrode Modality Development in Pulsed Electric Field Treatment Facilitates Biocellular Mechanism Study and Improves Cancer Ablation Efficacy.

    Science.gov (United States)

    Cen, Chao; Chen, Xinhua

    2017-01-01

    Pulsed electric field treatment is now widely used in diverse biological and medical applications: gene delivery, electrochemotherapy, and cancer therapy. This minimally invasive technique has several advantages over traditional ablation techniques, such as nonthermal elimination and blood vessel spare effect. Different electrodes are subsequently developed for a specific treatment purpose. Here, we provide a systematic review of electrode modality development in pulsed electric field treatment. For electrodes invented for experiment in vitro, sheet electrode and electrode cuvette, electrodes with high-speed fluorescence imaging system, electrodes with patch-clamp, and electrodes with confocal laser scanning microscopy are introduced. For electrodes invented for experiment in vivo, monopolar electrodes, five-needle array electrodes, single-needle bipolar electrode, parallel plate electrodes, and suction electrode are introduced. The pulsed electric field provides a promising treatment for cancer.

  2. Advanced divertor experiments on DIII-D

    International Nuclear Information System (INIS)

    Schaffer, M.J.; Mahdavi, M.A.; Osborne, T.; Petrie, T.W.; Stambaugh, R.D.; Buchenauer, D.; Hill, D.N.; Klepper, C.C.

    1991-01-01

    The poloidal divertor is presently favored for next-step, high-power tokamaks. The DIII-D Advanced Divertor Program (ADP) aims to gain increased control over the divertor plasma and tokamak boundary conditions. This paper reports experiments done in the first phase of the ADP. The DIII-D lower divertor was modified by the addition of a toroidally symmetric, graphite-armoured, water-cooled divertor-biasing ring electrode at the entrance to a gas plenum. (In the past DIII-D operated with an open divertor.) The plenum will eventually contain a He cryogenic loop for active divertor pumping. The separatrix 'strike' position is controlled by the lower poloidal field shaping coils and can be varied smoothly from the ring electrode upper surface to the divertor floor far from the entrance aperture. External power, at up to 550 V and 8 kA separately, has been applied to the electrode to date. (author) 5 refs., 5 figs

  3. Advanced divertor experiments on DIII-D

    International Nuclear Information System (INIS)

    Schaffer, M.J.; Mahdavi, M.A.; Osborne, T.; Petrie, T.W.; Stambaugh, R.D.; Buchenauer, D.; Hill, D.N.; Klepper, C.C.

    1991-04-01

    The poloidal divertor is presently favored for next-step, high-power tokamaks. The DIII-D Advanced Divertor Program (ADP) aims to gain increased control over the divertor plasma and tokamak boundary conditions. This paper reports experiments done in the first phase of the ADP. The DIII-D lower divertor was modified by the addition of a toroidally symmetric, graphite-armoured, water-cooled divertor-biasing ring electrode at the entrance to a gas plenum. The plenum will eventually contain a He cryogenic loop for active divertor pumping. The separatrix ''strike'' position is controlled by the lower poloidal field shaping coils and can be varied smoothly from the ring electrode upper surface to the divertor floor far from the entrance aperture. External power, at up to 550 V and 8 kA separately, has been applied to the electrode to date. 5 refs., 5 figs

  4. Development of AC-coupled, poly-silicon biased, p-on-n silicon strip detectors in India for HEP experiments

    Science.gov (United States)

    Jain, Geetika; Dalal, Ranjeet; Bhardwaj, Ashutosh; Ranjan, Kirti; Dierlamm, Alexander; Hartmann, Frank; Eber, Robert; Demarteau, Marcel

    2018-02-01

    P-on-n silicon strip sensors having multiple guard-ring structures have been developed for High Energy Physics applications. The study constitutes the optimization of the sensor design, and fabrication of AC-coupled, poly-silicon biased sensors of strip width of 30 μm and strip pitch of 55 μm. The silicon wafers used for the fabrication are of 4 inch n-type, having an average resistivity of 2-5 k Ω cm, with a thickness of 300 μm. The electrical characterization of these detectors comprises of: (a) global measurements of total leakage current, and backplane capacitance; (b) strip and voltage scans of strip leakage current, poly-silicon resistance, interstrip capacitance, interstrip resistance, coupling capacitance, and dielectric current; and (c) charge collection measurements using ALiBaVa setup. The results of the same are reported here.

  5. Long Life Nickel Electrodes for Nickel-Hydrogen Cells: Fiber Substrates Nickel Electrodes

    Science.gov (United States)

    Rogers, Howard H.

    2000-01-01

    Samples of nickel fiber mat electrodes were investigated over a wide range of fiber diameters, electrode thickness, porosity and active material loading levels. Thickness' were 0.040, 0.060 and 0.080 inches for the plaque: fiber diameters were primarily 2, 4, and 8 micron and porosity was 85, 90, and 95%. Capacities of 3.5 in. diameter electrodes were determined in the flooded condition with both 26 and 31% potassium hydroxide solution. These capacity tests indicated that the highest capacities per unit weight were obtained at the 90% porosity level with a 4 micron diameter fiber plaque. It appeared that the thinner electrodes had somewhat better performance, consistent with sintered electrode history. Limited testing with two-positive-electrode boiler plate cells was also carried out. Considerable difficulty with constructing the cells was encountered with short circuits the major problem. Nevertheless, four cells were tested. The cell with 95% porosity electrodes failed during conditioning cycling due to high voltage during charge. Discharge showed that this cell had lost nearly all of its capacity. The other three cells after 20 conditioning cycles showed capacities consistent with the flooded capacities of the electrodes. Positive electrodes made from fiber substrates may well show a weight advantage of standard sintered electrodes, but need considerably more work to prove this statement. A major problem to be investigated is the lower strength of the substrate compared to standard sintered electrodes. Problems with welding of leads were significant and implications that the electrodes would expand more than sintered electrodes need to be investigated. Loading levels were lower than had been expected based on sintered electrode experiences and the lower loading led to lower capacity values. However, lower loading causes less expansion and contraction during cycling so that stress on the substrate is reduced.

  6. The Composite Insertion Electrode

    DEFF Research Database (Denmark)

    Atlung, Sven; Zachau-Christiansen, Birgit; West, Keld

    1984-01-01

    The specific energy obtainable by discharge of porous insertion electrodes is limited by electrolyte depletion in thepores. This can be overcome using a solid ion conductor as electrolyte. The term "composite" is used to distinguishthese electrodes from porous electrodes with liquid electrolyte...

  7. Near-Electrode Imager

    Energy Technology Data Exchange (ETDEWEB)

    Rathke, Jerome W.; Klingler, Robert J.; Woelk, Klaus; Gerald, Rex E.,II

    1999-05-01

    An apparatus, near-electrode imager, for employing nuclear magnetic resonance imaging to provide in situ measurements of electrochemical properties of a sample as a function of distance from a working electrode. The near-electrode imager use the radio frequency field gradient within a cylindrical toroid cavity resonator to provide high-resolution nuclear magnetic resonance spectral information on electrolyte materials.

  8. CPI Bias in Korea

    Directory of Open Access Journals (Sweden)

    Chul Chung

    2007-12-01

    Full Text Available We estimate the CPI bias in Korea by employing the approach of Engel’s Law as suggested by Hamilton (2001. This paper is the first attempt to estimate the bias using Korean panel data, Korean Labor and Income Panel Study(KLIPS. Following Hamilton’s model with non­linear specification correction, our estimation result shows that the cumulative CPI bias over the sample period (2000-2005 was 0.7 percent annually. This CPI bias implies that about 21 percent of the inflation rate during the period can be attributed to the bias. In light of purchasing power parity, we provide an interpretation of the estimated bias.

  9. Insulated electrocardiographic electrodes. [without paste electrolyte

    Science.gov (United States)

    David, R. M.; Portnoy, W. A. (Inventor)

    1975-01-01

    An integrated system is disclosed including an insulated electrode and an impedance transformer which can be assembled in a small plastic housing and used for the acquisition of electrocardiographic data. The electrode may be employed without a paste electrolyte and may be attached to the body for extended usage without producing skin reaction. The electrode comprises a thin layer of suitable nontoxic dielectric material preferably deposited by radio frequency sputtering onto a conductive substrate. The impedance transformer preferably comprises an operational amplifier having an FET input stage connected in the unity gain configuration which provides a very low lower cut-off frequency, a high input impedance with a very small input bias current, a low output impedance, and a high signal-to-noise ratio.

  10. DNA-FET using carbon nanotube electrodes

    International Nuclear Information System (INIS)

    Sasaki, T K; Ikegami, A; Aoki, N; Ochiai, Y

    2006-01-01

    We demonstrate DNA field effect transistor (DNA-FET) using multiwalled carbon nanotube (MWNT) as nano-structural source and drain electrodes. The MWNT electrodes have been fabricated by focused ion-beam bombardment (FIBB). A very short channel, approximately 50 nm, was easily formed between the severed MWNT. The current-voltage (I-V) characteristics of DNA molecules between the MWNT electrodes showed hopping transport property. We have also measured the gate-voltage dependence in the I-V characteristics and found that poly DNA molecules exhibits p-type conduction. The transport of DNA-FET can be explained by two hopping lengths which depend on the range of the source-drain bias voltages

  11. Adaptable history biases in human perceptual decisions.

    Science.gov (United States)

    Abrahamyan, Arman; Silva, Laura Luz; Dakin, Steven C; Carandini, Matteo; Gardner, Justin L

    2016-06-21

    When making choices under conditions of perceptual uncertainty, past experience can play a vital role. However, it can also lead to biases that worsen decisions. Consistent with previous observations, we found that human choices are influenced by the success or failure of past choices even in a standard two-alternative detection task, where choice history is irrelevant. The typical bias was one that made the subject switch choices after a failure. These choice history biases led to poorer performance and were similar for observers in different countries. They were well captured by a simple logistic regression model that had been previously applied to describe psychophysical performance in mice. Such irrational biases seem at odds with the principles of reinforcement learning, which would predict exquisite adaptability to choice history. We therefore asked whether subjects could adapt their irrational biases following changes in trial order statistics. Adaptability was strong in the direction that confirmed a subject's default biases, but weaker in the opposite direction, so that existing biases could not be eradicated. We conclude that humans can adapt choice history biases, but cannot easily overcome existing biases even if irrational in the current context: adaptation is more sensitive to confirmatory than contradictory statistics.

  12. Manufacturing process and electrode properties of palladium-electroded ionic polymer–metal composite

    International Nuclear Information System (INIS)

    Chang, Longfei; Chen, Hualing; Zhu, Zicai; Li, Bo

    2012-01-01

    This paper primarily focuses on the manufacturing process of palladium-electroded ionic polymer–metal composite (IPMC). First, according to the special properties of Pd, many experiments were done to determine several specific procedures, including the addition of a reducing agent and the time consumed. Subsequently, the effects of the core manufacturing steps on the electrode morphology were revealed by scanning electron microscopy studies of 22 IPMC samples treated with different combinations of manufacturing steps. Finally, the effects of electrode characteristics on the electromechanical properties, including the sheet resistivity, the elastic modulus and the electro-active performance, of IPMCs were evaluated experimentally and analyzed according to the electrode morphology. (paper)

  13. Electrodes for bio-application: recording and stimulation

    International Nuclear Information System (INIS)

    Fontes, M B A

    2013-01-01

    Recording and stimulation electrodes applied on excitable tissue are the basis of electrophysiological research, such as brain, muscles, peripheral nerves or sensory systems. Electrode-electrolyte impedance is one of the important characteristics due to its influence on the signal/noise ratio, signal distortion and built-up voltage. Strategies to lowering and tuning the impedance are achieved by biasing iridium oxide modified platinum microelectrodes. Surface and impedance analysis after pulse stimulation are also addressed.

  14. Effects of attention bias modification with short and long stimulus-duration: A randomized experiment with individuals with subclinical social anxiety.

    Science.gov (United States)

    Liang, Chi-Wen; Hsu, Wen-Yau

    2016-06-30

    This study investigated the differential effects of two attention bias modification (ABM) with different stimulus durations. Seventy-two undergraduates with subclinical social anxiety were randomly assigned to one of four conditions: an ABM condition with either a 100-ms or a 500-ms stimulus duration (ABM-100/ ABM-500) or an attention placebo (AP) condition with either a 100-ms or a 500-ms stimulus duration (AP-100/ AP-500). Participants completed the pre-assessments, eight attentional training sessions, and post-assessments. A modified Posner paradigm was used to assess changes in attentional processing. After completion of attentional training, the ABM-100 group significantly speeded up their responses to 100-ms invalid trials, regardless of the word type. The ABM-100 group also exhibited significant reduced latencies to 500-ms invalid social threat trials and a marginally significant reduced latencies to 500-ms invalid neutral trials. The ABM-500 group showed significant reduced latencies to 500-ms invalid social threat trials. Both ABMs significantly reduced participants' fear of negative evaluations and interactional anxiousness relative to their comparative AP. The effects on social anxiety did not differ between the two ABMs. This study suggests that although both ABMs using short and long stimulus durations reduce some aspects of social anxiety, they influence participants' attentional disengagement in different ways. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  15. Sampler bias -- Phase 1

    International Nuclear Information System (INIS)

    Blanchard, R.J.

    1995-01-01

    This documents Phase 1 determinations on sampler induced bias for four sampler types used in tank characterization. Each sampler, grab sampler or bottle-on-a-string, auger sampler, sludge sampler and universal sampler, is briefly discussed and their physical limits noted. Phase 2 of this document will define additional testing and analysis to further define Sampler Bias

  16. Photovoltaic Bias Generator

    Science.gov (United States)

    2018-02-01

    Department of the Army position unless so designated by other authorized documents. Citation of manufacturer’s or trade names does not constitute an... Interior view of the photovoltaic bias generator showing wrapped-wire side of circuit board...3 Fig. 4 Interior view of the photovoltaic bias generator showing component side of circuit board

  17. Biases in categorization

    NARCIS (Netherlands)

    Das-Smaal, E.A.

    1990-01-01

    On what grounds can we conclude that an act of categorization is biased? In this chapter, it is contended that in the absence of objective norms of what categories actually are, biases in categorization can only be specified in relation to theoretical understandings of categorization. Therefore, the

  18. A Principal Components Analysis of Dynamic Spatial Memory Biases

    Science.gov (United States)

    Motes, Michael A.; Hubbard, Timothy L.; Courtney, Jon R.; Rypma, Bart

    2008-01-01

    Research has shown that spatial memory for moving targets is often biased in the direction of implied momentum and implied gravity, suggesting that representations of the subjective experiences of these physical principles contribute to such biases. The present study examined the association between these spatial memory biases. Observers viewed…

  19. Whiteliness and Institutional Racism: Hiding behind (Un)Conscious Bias

    Science.gov (United States)

    Tate, Shirley Anne; Page, Damien

    2018-01-01

    'Unconscious bias happens by our brains making incredibly quick judgements and assessments without us realising. Biases are influenced by background, cultural environment and experiences and we may not be aware of these views and opinions, or of their full impact and implications. This article opposes this point of view by arguing that bias is not…

  20. Approximate Bias Correction in Econometrics

    OpenAIRE

    James G. MacKinnon; Anthony A. Smith Jr.

    1995-01-01

    This paper discusses ways to reduce the bias of consistent estimators that are biased in finite samples. It is necessary that the bias function, which relates parameter values to bias, should be estimable by computer simulation or by some other method. If so, bias can be reduced or, in some cases that may not be unrealistic, even eliminated. In general, several evaluations of the bias function will be required to do this. Unfortunately, reducing bias may increase the variance, or even the mea...

  1. Effect of Reverse Bias Stress on Leakage Currents and Breakdown Voltages of Solid Tantalum Capacitors

    Science.gov (United States)

    Teverovsky, Alexander A.

    2011-01-01

    The majority of solid tantalum capacitors are produced by high-temperature sintering of a fine tantalum powder around a tantalum wire followed by electrolytic anodization that forms a thin amorphous Ta2O5 dielectric layer and pyrolysis of manganese nitrite on the oxide to create a conductive manganese dioxide electrode. A contact to tantalum wire is used as anode terminal and to the manganese layer as a cathode terminal of the device. This process results in formation of an asymmetric Ta -- Ta2O5 -- MnO2 capacitor that has different characteristics at forward (positive bias applied to tantalum) and reverse (positive bias applied to manganese cathode) voltages. Reverse bias currents might be several orders of magnitude larger than forward leakage currents so I-V characteristics of tantalum capacitors resemble characteristics of semiconductor rectifiers. Asymmetric I-V characteristics of Ta -- anodic Ta2O5 systems have been observed at different top electrode materials including metals, electrolytes, conductive polymers, and manganese oxide thus indicating that this phenomenon is likely related to the specifics of the Ta -- Ta2O5 interface. There have been multiple attempts to explain rectifying characteristics of capacitors employing anodic tantalum pentoxide dielectrics. A brief review of works related to reverse bias (RB) behavior of tantalum capacitors shows that the mechanism of conduction in Ta -- Ta2O5 systems is still not clear and more testing and analysis is necessary to understand the processes involved. If tantalum capacitors behave just as rectifiers, then the assessment of the safe reverse bias operating conditions would be a relatively simple task. Unfortunately, these parts can degrade with time under reverse bias significantly, and this further complicates analysis of the I-V characteristics and establishing safe operating areas of the parts. On other hand, time dependence of reverse currents might provide additional information for investigation of

  2. Uncharged positive electrode composition

    Science.gov (United States)

    Kaun, Thomas D.; Vissers, Donald R.; Shimotake, Hiroshi

    1977-03-08

    An uncharged positive-electrode composition contains particulate lithium sulfide, another alkali metal or alkaline earth metal compound other than sulfide, e.g., lithium carbide, and a transition metal powder. The composition along with a binder, such as electrolytic salt or a thermosetting resin is applied onto an electrically conductive substrate to form a plaque. The plaque is assembled as a positive electrode within an electrochemical cell opposite to a negative electrode containing a material such as aluminum or silicon for alloying with lithium. During charging, lithium alloy is formed within the negative electrode and transition metal sulfide such as iron sulfide is produced within the positive electrode. Excess negative electrode capacity over that from the transition metal sulfide is provided due to the electrochemical reaction of the other than sulfide alkali metal or alkaline earth metal compound.

  3. Handbook of reference electrodes

    CERN Document Server

    Inzelt, György; Scholz, Fritz

    2013-01-01

    Reference Electrodes are a crucial part of any electrochemical system, yet an up-to-date and comprehensive handbook is long overdue. Here, an experienced team of electrochemists provides an in-depth source of information and data for the proper choice and construction of reference electrodes. This includes all kinds of applications such as aqueous and non-aqueous solutions, ionic liquids, glass melts, solid electrolyte systems, and membrane electrodes. Advanced technologies such as miniaturized, conducting-polymer-based, screen-printed or disposable reference electrodes are also covered. Essen

  4. Why some women have an optimistic or a pessimistic bias about their breast cancer risk? Experiences, heuristics, and knowledge of risk factors

    OpenAIRE

    Katapodi, Maria C.; Dodd, Marylin J.; Facione, Noreen C.; Humphreys, Janice C.; Lee, Kathryn A.

    2010-01-01

    Perceived risk to a health problem is formed by inferential rules called heuristics and by comparative judgments that assess how one's risk compares to the risk of others. The purpose of this cross-sectional, community-based survey was to examine how experiences with breast cancer, knowledge of risk factors, and specific heuristics inform risk judgments for oneself, for friends/peers, and comparative judgments for breast cancer (risk friends/peers - risk self). We recruited an English-speakin...

  5. Tapping to a slow tempo in the presence of simple and complex meters reveals experience-specific biases for processing music.

    Directory of Open Access Journals (Sweden)

    Sangeeta Ullal-Gupta

    Full Text Available Musical meters vary considerably across cultures, yet relatively little is known about how culture-specific experience influences metrical processing. In Experiment 1, we compared American and Indian listeners' synchronous tapping to slow sequences. Inter-tone intervals contained silence or to-be-ignored rhythms that were designed to induce a simple meter (familiar to Americans and Indians or a complex meter (familiar only to Indians. A subset of trials contained an abrupt switch from one rhythm to another to assess the disruptive effects of contradicting the initially implied meter. In the unfilled condition, both groups tapped earlier than the target and showed large tap-tone asynchronies (measured in relative phase. When inter-tone intervals were filled with simple-meter rhythms, American listeners tapped later than targets, but their asynchronies were smaller and declined more rapidly. Likewise, asynchronies rose sharply following a switch away from simple-meter but not from complex-meter rhythm. By contrast, Indian listeners performed similarly across all rhythm types, with asynchronies rapidly declining over the course of complex- and simple-meter trials. For these listeners, a switch from either simple or complex meter increased asynchronies. Experiment 2 tested American listeners but doubled the duration of the synchronization phase prior to (and after the switch. Here, compared with simple meters, complex-meter rhythms elicited larger asynchronies that declined at a slower rate, however, asynchronies increased after the switch for all conditions. Our results provide evidence that ease of meter processing depends to a great extent on the amount of experience with specific meters.

  6. Tapping to a slow tempo in the presence of simple and complex meters reveals experience-specific biases for processing music.

    Science.gov (United States)

    Ullal-Gupta, Sangeeta; Hannon, Erin E; Snyder, Joel S

    2014-01-01

    Musical meters vary considerably across cultures, yet relatively little is known about how culture-specific experience influences metrical processing. In Experiment 1, we compared American and Indian listeners' synchronous tapping to slow sequences. Inter-tone intervals contained silence or to-be-ignored rhythms that were designed to induce a simple meter (familiar to Americans and Indians) or a complex meter (familiar only to Indians). A subset of trials contained an abrupt switch from one rhythm to another to assess the disruptive effects of contradicting the initially implied meter. In the unfilled condition, both groups tapped earlier than the target and showed large tap-tone asynchronies (measured in relative phase). When inter-tone intervals were filled with simple-meter rhythms, American listeners tapped later than targets, but their asynchronies were smaller and declined more rapidly. Likewise, asynchronies rose sharply following a switch away from simple-meter but not from complex-meter rhythm. By contrast, Indian listeners performed similarly across all rhythm types, with asynchronies rapidly declining over the course of complex- and simple-meter trials. For these listeners, a switch from either simple or complex meter increased asynchronies. Experiment 2 tested American listeners but doubled the duration of the synchronization phase prior to (and after) the switch. Here, compared with simple meters, complex-meter rhythms elicited larger asynchronies that declined at a slower rate, however, asynchronies increased after the switch for all conditions. Our results provide evidence that ease of meter processing depends to a great extent on the amount of experience with specific meters.

  7. Bias aware Kalman filters

    DEFF Research Database (Denmark)

    Drecourt, J.-P.; Madsen, H.; Rosbjerg, Dan

    2006-01-01

    This paper reviews two different approaches that have been proposed to tackle the problems of model bias with the Kalman filter: the use of a colored noise model and the implementation of a separate bias filter. Both filters are implemented with and without feedback of the bias into the model state....... The colored noise filter formulation is extended to correct both time correlated and uncorrelated model error components. A more stable version of the separate filter without feedback is presented. The filters are implemented in an ensemble framework using Latin hypercube sampling. The techniques...... are illustrated on a simple one-dimensional groundwater problem. The results show that the presented filters outperform the standard Kalman filter and that the implementations with bias feedback work in more general conditions than the implementations without feedback. 2005 Elsevier Ltd. All rights reserved....

  8. Biases in casino betting

    Directory of Open Access Journals (Sweden)

    James Sundali

    2006-07-01

    Full Text Available We examine two departures of individual perceptions of randomness from probability theory: the hot hand and the gambler's fallacy, and their respective opposites. This paper's first contribution is to use data from the field (individuals playing roulette in a casino to demonstrate the existence and impact of these biases that have been previously documented in the lab. Decisions in the field are consistent with biased beliefs, although we observe significant individual heterogeneity in the population. A second contribution is to separately identify these biases within a given individual, then to examine their within-person correlation. We find a positive and significant correlation across individuals between hot hand and gambler's fallacy biases, suggesting a common (root cause of the two related errors. We speculate as to the source of this correlation (locus of control, and suggest future research which could test this speculation.

  9. Introduction to Unconscious Bias

    Science.gov (United States)

    Schmelz, Joan T.

    2010-05-01

    We all have biases, and we are (for the most part) unaware of them. In general, men and women BOTH unconsciously devalue the contributions of women. This can have a detrimental effect on grant proposals, job applications, and performance reviews. Sociology is way ahead of astronomy in these studies. When evaluating identical application packages, male and female University psychology professors preferred 2:1 to hire "Brian” over "Karen” as an assistant professor. When evaluating a more experienced record (at the point of promotion to tenure), reservations were expressed four times more often when the name was female. This unconscious bias has a repeated negative effect on Karen's career. This talk will introduce the concept of unconscious bias and also give recommendations on how to address it using an example for a faculty search committee. The process of eliminating unconscious bias begins with awareness, then moves to policy and practice, and ends with accountability.

  10. Enhanced confinement with plasma biasing in the MST reversed field pinch

    International Nuclear Information System (INIS)

    Craig, D.; Almagri, A.F.; Anderson, J.K.

    1997-06-01

    We report an increase in particle confinement with plasma biasing in a reversed field pinch. Miniature plasma sources are used as electrodes to negatively bias the plasma at the edge (r/a ∼ 0.9). Particle content increases and H α radiation decreases upon application of bias and global particle confinement roughly doubles as a result. Measurements of plasma potential, impurity flow, and floating potential fluctuations indicate that strong flows are produced and that electrostatic fluctuations are reduced

  11. Australia's Bond Home Bias

    OpenAIRE

    Anil V. Mishra; Umaru B. Conteh

    2014-01-01

    This paper constructs the float adjusted measure of home bias and explores the determinants of bond home bias by employing the International Monetary Fund's high quality dataset (2001 to 2009) on cross-border bond investment. The paper finds that Australian investors' prefer investing in countries with higher economic development and more developed bond markets. Exchange rate volatility appears to be an impediment for cross-border bond investment. Investors prefer investing in countries with ...

  12. Analysis of the data from the NEMO3 experiment and search for neutrinoless double beta decay - Study of systematic bias of the calorimeter and development of analysis tools

    International Nuclear Information System (INIS)

    Hugon, C.

    2012-11-01

    The NEMO3 experiment was researching the neutrinoless double-β (0ndb) decay by using various sources of double beta decay isotopes (mainly 100 Mo, 82 Se, 116 Cd and 130 Te for about 10 kg in total). The detector was located in the underground laboratory of Modane (Italy) in the halfway point of the Frejus tunnel. This experiment demonstrated that the 'tracko-calo' technology is really competitive and, in addition, it gives new results for the 2-neutrinos double-β (2ndb) decay and the (0ndb) decays research. Moreover it opened an new way for its successor SuperNEMO, which aim is to reach a mass of 100 kg of 82 Se (for a sensitivity of 10 26 years). The main goal of the thesis is to measure the 2ndb and 0ndb decay of the 100 Mo to the excited state 0 1 + of the 100 Ru thanks to the whole NEMO3 data, with new original methods of analysis and through the development of the collaboration analysis software. The results obtained for the ground states (gs) and excited states 2ndb of the 100 Mo are for the half-lives: T(2nbd, gs)=[7.05±0.01(stat)±0.54(syst)]*10 18 years and T(2ndb, 0 1 + )=[6.15±1.1(sta)±0.78]*10 20 years. Those results are compatibles with the last ones published by the collaboration. For the 0ndb(0 1 + ), this work gave a half-life of T(0ndb, 0 1 + ) > 2.6*10 23 years, improving significantly the last published results. Furthermore those methods also allowed to present a new and more exhaustive background noise model for this experiment. The second point of this work was to measure the systematics errors of the NEMO3 calorimeter, among others due to the wavelength of the NEMO3 calibration systems. This work was done using a new test bench based on LED. This bench also allowed to contribute to the development of the SuperNEMO calorimeter, especially in the time characteristic and the energy linearity measurement of the photomultiplier intended to the demonstrator of the experiments. (author)

  13. Why some women have an optimistic or a pessimistic bias about their breast cancer risk: experiences, heuristics, and knowledge of risk factors.

    Science.gov (United States)

    Katapodi, Maria C; Dodd, Marylin J; Facione, Noreen C; Humphreys, Janice C; Lee, Kathryn A

    2010-01-01

    Perceived risk to a health problem is formed by inferential rules called heuristics and by comparative judgments that assess how one's risk compares to the risk of others. The purpose of this cross-sectional, community-based survey was to examine how experiences with breast cancer, knowledge of risk factors, and specific heuristics inform risk judgments for oneself, for friends/peers, and comparative judgments for breast cancer (risk friends/peers - risk self). We recruited an English-speaking, multicultural (57% nonwhite) sample of 184 middle-aged (47 + or - 12 years old), well-educated women. Fifty percent of participants perceived that their breast cancer risk was the same as the risk of their friends/peers; 10% were pessimistic (risk friends/peers - risk self 0). Family history of breast cancer and worry informed risk judgments for oneself. The availability and cultural heuristics specific for black women informed risk judgments for friends/peers. Knowledge of risk factors and interactions of knowledge with the availability, representativeness, and simulation heuristics informed comparative judgments (risk friends/peers - risk self). We discuss cognitive mechanisms with which experiences, knowledge, and heuristics influence comparative breast cancer risk judgments. Risk communication interventions should assess knowledge deficits, contextual variables, and specific heuristics that activate differential information processing mechanisms.

  14. [Verification of skin paste electrodes used in wireless polysomnography].

    Science.gov (United States)

    Ma, Y D; Huang, D; Chen, Y F; Jiang, H Y; Liu, J H; Sun, H Q; Li, Z H

    2018-04-18

    To explore an electrode suitable for wireless portable sleep monitoring equipment and analyze the result of the signals of electrooculogram (EOG) and electroencephalography (EEG) collected by this kind of flexible electrodes. The flexible electrodes were prepared by microelectromechanical systems (MEMS) technology. This kind of electrodes consisted parylene, chromium, and gold. Parylene, the flexible substrate of this kind of flexible electrodes, was of biocompatibility. Between parylene and gold there was an adhesion layer of chromium, which connected parylene and gold tightly. Then the flexible electrodes were stuck to medical adhesive tape. The electrodes were designed and made into a grid to make sure that the medical adhesive tape could tape on the skin tightly, so that the contact impedance between the electrodes and the skin would be reduced. Then the alternating current impedance of the electrode were tested by the CHI660E electrochemical workstation after the electrode was achieved. To make sure that this kind of electrodes could be used in EOG monitoring, the electrodes were connected to a wireless signal acquisition suite containing special biological signal acquisition and digital processing chip to gather different sites around the eyes and the electrical signals of different directions of the eye movements, then analyzed the signal-to-noise ratio of the EOG. At the end, the Philips A6 polysomnography was used to compare the noise amplitude of the EEG signals collected by the flexible electrode and the gold cup electrode. The electrodes stuck to the skin tightly, and these electrodes could collect signals that we wanted while the experiment was performed. The alternating current impedance of the flexible electrode was between 4 kΩ and 13 kΩ while with the frequency of alternating current under 100 Hz, most EEG signal frequencies were at this range. The EOG signals collected by the flexible electrodes were in line with the clinical requirements. The

  15. Electrode stabilizing materials

    Science.gov (United States)

    Amine, Khalil; Abouimrane, Ali; Moore, Jeffrey S.; Odom, Susan A.

    2015-11-03

    An electrolyte includes a polar aprotic solvent; an alkali metal salt; and an electrode stabilizing compound that is a monomer, which when polymerized forms an electrically conductive polymer. The electrode stabilizing compound is a thiophene, a imidazole, a anilines, a benzene, a azulene, a carbazole, or a thiol. Electrochemical devices may incorporate such electrolytes.

  16. Durable fuel electrode

    DEFF Research Database (Denmark)

    2017-01-01

    the composite. The invention also relates to the use of the composite as a fuel electrode, solid oxide fuel cell, and/or solid oxide electrolyser. The invention discloses a composite for an electrode, comprising a three-dimensional network of dispersed metal particles, stabilised zirconia particles and pores...

  17. Multi-Electrode Resistivity Probe for Investigation of Local Temperature Inside Metal Shell Battery Cells via Resistivity: Experiments and Evaluation of Electrical Resistance Tomography

    Directory of Open Access Journals (Sweden)

    Xiaobin Hong

    2015-01-01

    Full Text Available Direct Current (DC electrical resistivity is a material property that is sensitive to temperature changes. In this paper, the relationship between resistivity and local temperature inside steel shell battery cells (two commercial 10 Ah and 4.5 Ah lithium-ion cells is innovatively studied by Electrical Resistance Tomography (ERT. The Schlumberger configuration in ERT is applied to divide the cell body into several blocks distributed in different levels, where the apparent resistivities are measured by multi-electrode surface probes. The investigated temperature ranges from −20 to 80 °C. Experimental results have shown that the resistivities mainly depend on temperature changes in each block of the two cells used and the function of the resistivity and temperature can be fitted to the ERT-measurement results in the logistical-plot. Subsequently, the dependence of resistivity on the state of charge (SOC is investigated, and the SOC range of 70%–100% has a remarkable impact on the resistivity at low temperatures. The proposed approach under a thermal cool down regime is demonstrated to monitor the local transient temperature.

  18. The source of the truth bias: Heuristic processing?

    Science.gov (United States)

    Street, Chris N H; Masip, Jaume

    2015-06-01

    People believe others are telling the truth more often than they actually are; this is called the truth bias. Surprisingly, when a speaker is judged at multiple points across their statement the truth bias declines. Previous claims argue this is evidence of a shift from (biased) heuristic processing to (reasoned) analytical processing. In four experiments we contrast the heuristic-analytic model (HAM) with alternative accounts. In Experiment 1, the decrease in truth responding was not the result of speakers appearing more deceptive, but was instead attributable to the rater's processing style. Yet contrary to HAMs, across three experiments we found the decline in bias was not related to the amount of processing time available (Experiments 1-3) or the communication channel (Experiment 2). In Experiment 4 we found support for a new account: that the bias reflects whether raters perceive the statement to be internally consistent. © 2015 Scandinavian Psychological Associations and John Wiley & Sons Ltd.

  19. Electrode placement during electro-desalination of

    DEFF Research Database (Denmark)

    Ottosen, Lisbeth M.; Andersson, Lovisa C. H.

    2017-01-01

    Carved stone sculptures and ornaments can be severely damaged by salt induced decay. Often the irregular surfaces are decomposed, and the artwork is lost. The present paper is an experimental investigation on the possibility for using electro-desalination for treatment of stone with irregular shape....... Electro-desalination experiments were made with different duration to follow the progress. Successful desalination of the whole stone piece was obtained, showing that also parts not being placed directly between the electrodes were desalinated. This is important in case of salt damaged carved stones......, where the most fragile parts thus can be desalinated without physically placing electrodes on them. The Cl removal rate was higher in the areas closest to the electrodes and slowest in the part, which was not placed directly between the electrodes. This is important to incorporate in the monitoring...

  20. Simulating publication bias

    DEFF Research Database (Denmark)

    Paldam, Martin

    is censoring: selection by the size of estimate; SR3 selects the optimal combination of fit and size; and SR4 selects the first satisficing result. The last four SRs are steered by priors and result in bias. The MST and the FAT-PET have been developed for detection and correction of such bias. The simulations......Economic research typically runs J regressions for each selected for publication – it is often selected as the ‘best’ of the regressions. The paper examines five possible meanings of the word ‘best’: SR0 is ideal selection with no bias; SR1 is polishing: selection by statistical fit; SR2...... are made by data variation, while the model is the same. It appears that SR0 generates narrow funnels much at odds with observed funnels, while the other four funnels look more realistic. SR1 to SR4 give the mean a substantial bias that confirms the prior causing the bias. The FAT-PET MRA works well...

  1. Minimally Invasive Placement of Spinal Cord Stimulator Paddle Electrodes Is Associated With Improved Perioperative and Long-Term Experience Among Neuropathic Pain Patients.

    Science.gov (United States)

    Shamji, Mohammed F; Paul, Darcia; Mednikov, Alina

    2018-03-01

    Prospective, observational cohort study. This study compared in-hospital and long-term outcomes among spinal cord stimulation (SCS) patients undergoing paddle insertion by open or minimally invasive surgery (MIS) approaches. Patients with treatment-refractory extremity neuropathic pain may benefit from SCS. Conventional placement of surgical paddles for an external neurostimulation trial is through open laminectomy, but MIS techniques may offer advantages. Twenty SCS patients were prospectively assessed. Open patients underwent caudal thoracic laminectomy for multicolumnar electrode paddle placement. MIS patients underwent paddle placement through interlaminar flavectomy using tubular retractors. Demographic data included age, sex, underlying diagnosis, and preoperative visual analog scale (VAS) extremity scores. Intraoperative data included operative duration, blood loss, and number of device passages to achieve final position. Perioperative data included VAS back pain scores; trial data included time-to-trial and time-to-decision. Postoperative data included 1 month VAS back pain scores and 1 year follow-up device complications. No demographic differences were observed among surgical cohorts. MIS procedures had shorter operative duration (P = 0.03), less blood loss (P patients reported less perioperative surgical back pain (P patients who also made sooner decision whether to implant the SCS device (2.8 ± 1.4 vs 4.3 ± 1.0 days, P = 0.013). Similar 1 month back pain scores were reported between surgical cohorts (P = 0.08). MIS techniques for SCS surgical paddle implantation is associated with less perioperative morbidity and surgical site back pain, shorter external neurostimulator trial duration, and long-term device stability benefits. 2.

  2. Bias-dependent oscillatory electron transport of monatomic sulfur chains

    KAUST Repository

    Yu, Jing-Xin; Cheng, Yan; Sanvito, Stefano; Chen, Xiang-Rong

    2012-01-01

    The bias-dependent oscillatory electron transport of monatomic sulfur chains sandwiched between gold electrodes is investigated with density functional theory and non-equilibrium Green's function method. At zero bias, in contrast to the typical odd-even oscillations observed in most metallic chains, we find that the conductance oscillates with a period of four atoms. However, as the bias voltage is increased the current displays a two-atom periodicity. This emerges gradually, first for the longer chains and then, at voltages larger than 0.7 V, for lengths. The oscillatory behaviors are analyzed by the density of states and the energy-dependent and bias-dependent transmission coefficients. © 2012 American Institute of Physics.

  3. Bias-dependent oscillatory electron transport of monatomic sulfur chains

    KAUST Repository

    Yu, Jing-Xin

    2012-01-01

    The bias-dependent oscillatory electron transport of monatomic sulfur chains sandwiched between gold electrodes is investigated with density functional theory and non-equilibrium Green\\'s function method. At zero bias, in contrast to the typical odd-even oscillations observed in most metallic chains, we find that the conductance oscillates with a period of four atoms. However, as the bias voltage is increased the current displays a two-atom periodicity. This emerges gradually, first for the longer chains and then, at voltages larger than 0.7 V, for lengths. The oscillatory behaviors are analyzed by the density of states and the energy-dependent and bias-dependent transmission coefficients. © 2012 American Institute of Physics.

  4. Measuring Agricultural Bias

    DEFF Research Database (Denmark)

    Jensen, Henning Tarp; Robinson, Sherman; Tarp, Finn

    The measurement issue is the key issue in the literature on trade policy-induced agri-cultural price incentive bias. This paper introduces a general equilibrium effective rate of protection (GE-ERP) measure, which extends and generalizes earlier partial equilibrium nominal protection measures...... shares and intersectoral linkages - are crucial for determining the sign and magnitude of trade policy bias. The GE-ERP measure is therefore uniquely suited to capture the full impact of trade policies on agricultural price incentives. A Monte Carlo procedure confirms that the results are robust....... For the 15 sample countries, the results indicate that the agricultural price incentive bias, which was generally perceived to exist during the 1980s, was largely eliminated during the 1990s. The results also demonstrate that general equilibrium effects and country-specific characteristics - including trade...

  5. Current-Induced Forces and Hot Spots in Biased Nanojunctions

    DEFF Research Database (Denmark)

    Lu, Jing Tao; Christensen, Rasmus Bjerregaard; Wang, Jian-Sheng

    2015-01-01

    We investigate theoretically the interplay of current-induced forces (CIFs), Joule heating, and heat transport inside a current-carrying nanoconductor. We find that the CIFs, due to the electron-phonon coherence, can control the spatial heat dissipation in the conductor. This yields a significant...... asymmetric concentration of excess heating (hot spot) even for a symmetric conductor. When coupled to the electrode phonons, CIFs drive different phonon heat flux into the two electrodes. First-principles calculations on realistic biased nanojunctions illustrate the importance of the effect....

  6. Assessing the degradation of compliant electrodes for soft actuators

    Science.gov (United States)

    Rosset, Samuel; de Saint-Aubin, Christine; Poulin, Alexandre; Shea, Herbert R.

    2017-10-01

    We present an automated system to measure the degradation of compliant electrodes used in dielectric elastomer actuators (DEAs) over millions of cycles. Electrodes for DEAs generally experience biaxial linear strains of more than 10%. The decrease in electrode conductivity induced by this repeated fast mechanical deformation impacts the bandwidth of the actuator and its strain homogeneity. Changes in the electrode mechanical properties lead to reduced actuation strain. Rather than using an external actuator to periodically deform the electrodes, our measurement method consists of measuring the properties of an electrode in an expanding circle DEA. A programmable high voltage power supply drives the actuator with a square signal up to 1 kHz, periodically actuating the DEA, and thus stretching the electrodes. The DEA strain is monitored with a universal serial bus camera, while the resistance of the ground electrode is measured with a multimeter. The system can be used for any type of electrode. We validated the test setup by characterising a carbon black/silicone composite that we commonly use as compliant electrode. Although the composite is well-suited for tens of millions of cycles of actuation below 5%, we observe important degradation for higher deformations. When activated at a 20% radial strain, the electrodes suffer from important damage after a few thousand cycles, and an inhomogeneous actuation is observed, with the strain localised in a sub-region of the actuator only.

  7. Electrode-electrolyte interface model of tripolar concentric ring electrode and electrode paste.

    Science.gov (United States)

    Nasrollaholhosseini, Seyed Hadi; Steele, Preston; Besio, Walter G

    2016-08-01

    Electrodes are used to transform ionic currents to electrical currents in biological systems. Modeling the electrode-electrolyte interface could help to optimize the performance of the electrode interface to achieve higher signal to noise ratios. There are previous reports of accurate models for single-element biomedical electrodes. In this paper we develop a model for the electrode-electrolyte interface for tripolar concentric ring electrodes (TCRE) that are used to record brain signals.

  8. Tailored ion energy distributions on plasma electrodes

    International Nuclear Information System (INIS)

    Economou, Demetre J.

    2013-01-01

    As microelectronic device features continue to shrink approaching atomic dimensions, control of the ion energy distribution on the substrate during plasma etching and deposition becomes increasingly critical. The ion energy should be high enough to drive ion-assisted etching, but not too high to cause substrate damage or loss of selectivity. In many cases, a nearly monoenergetic ion energy distribution (IED) is desired to achieve highly selective etching. In this work, the author briefly reviews: (1) the fundamentals of development of the ion energy distribution in the sheath and (2) methods to control the IED on plasma electrodes. Such methods include the application of “tailored” voltage waveforms on an electrode in continuous wave plasmas, or the application of synchronous bias on a “boundary electrode” during a specified time window in the afterglow of pulsed plasmas

  9. Electrode phenomena, tensor conductivity and electrode heating in seeded argon

    Energy Technology Data Exchange (ETDEWEB)

    Croitoru, Z.; de Montardy, A.

    1963-04-15

    Contact potential drops along the electrodes often prevent measurements of ionized gas conductivity. In order to avoid such potential drops, a measurement cell using double probe technique was realized. By adding a third probe, it is also possible to measure the conductivity tensor components. Formulas commonly used are shown to be incorrect. In order to evaluate non- equilibrium conductivity, the excitation temperature of the seed is to be considered, rather than electron temperature, especially in small scale experiments, where charged particle losses by ambipolar diffusion are to be expected. (auth)

  10. Measuring agricultural policy bias

    DEFF Research Database (Denmark)

    Jensen, Henning Tarp; Robinson, Sherman; Tarp, Finn

    2010-01-01

    Measurement is a key issue in the literature on price incentive bias induced by trade policy. We introduce a general equilibrium measure of the relative effective rate of protection, which generalizes earlier protection measures. For our fifteen sample countries, results indicate that the agricul...

  11. Assessment of the production of J/psi, related to minimum bias events, in In-In collisions at 158 GeV/c per nucleon detected with the vertex telescope at the N60 experiment

    International Nuclear Information System (INIS)

    Chapsal, L.

    2009-01-01

    Theoretical physics considers, at the first start of the world, that matter may have existed as a Quark and Gluon Plasma (QGP). The heavy ion collisions in ultra-relativist energies are used to recreate this deconfined state of matter. NA50 experiment at CERN put into evidence, between others, the existence of an abnormal J/ψ suppression in its dimuon channel for the most central lead-lead collisions. NA60 collaboration allowed, with an improved precision, to ameliorate and to supplement NA50 results. One of the most remarkable results of this experiment was to show that the dimuon excess, noticed in the intermediate masses, was induced by direct dimuons what could be the first evidence for thermal dimuons. The job of this work is related to NA60 experiment for In-In collisions at 158 GeV/c by nucleon and concerns the production of the resonance J/ψ according to centrality. After corrections of the effects of acceptance and efficiencies, the centrality is deduced from the trace multiplicity by using the code of simulation VENUS. Production of J/ψ is normalized to minimum bias events which are insensible to the production of QGP. Results point out that production of J/ψ in In-In collisions is compatible with nuclear absorption with a cross section σ = (4.18 ± 0.35) mb. There is no therefore abnormal suppression, whatever the centrality is. This study concerned only a fraction of In-In data, complete statistics would allow more accuracy in this result. (author)

  12. Sensor employing internal reference electrode

    DEFF Research Database (Denmark)

    2013-01-01

    The present invention concerns a novel internal reference electrode as well as a novel sensing electrode for an improved internal reference oxygen sensor and the sensor employing same.......The present invention concerns a novel internal reference electrode as well as a novel sensing electrode for an improved internal reference oxygen sensor and the sensor employing same....

  13. Bias correction of daily satellite precipitation data using genetic algorithm

    Science.gov (United States)

    Pratama, A. W.; Buono, A.; Hidayat, R.; Harsa, H.

    2018-05-01

    Climate Hazards Group InfraRed Precipitation with Stations (CHIRPS) was producted by blending Satellite-only Climate Hazards Group InfraRed Precipitation (CHIRP) with Stasion observations data. The blending process was aimed to reduce bias of CHIRP. However, Biases of CHIRPS on statistical moment and quantil values were high during wet season over Java Island. This paper presented a bias correction scheme to adjust statistical moment of CHIRP using observation precipitation data. The scheme combined Genetic Algorithm and Nonlinear Power Transformation, the results was evaluated based on different season and different elevation level. The experiment results revealed that the scheme robustly reduced bias on variance around 100% reduction and leaded to reduction of first, and second quantile biases. However, bias on third quantile only reduced during dry months. Based on different level of elevation, the performance of bias correction process is only significantly different on skewness indicators.

  14. Decoupling Action Potential Bias from Cortical Local Field Potentials

    Directory of Open Access Journals (Sweden)

    Stephen V. David

    2010-01-01

    Full Text Available Neurophysiologists have recently become interested in studying neuronal population activity through local field potential (LFP recordings during experiments that also record the activity of single neurons. This experimental approach differs from early LFP studies because it uses high impendence electrodes that can also isolate single neuron activity. A possible complication for such studies is that the synaptic potentials and action potentials of the small subset of isolated neurons may contribute disproportionately to the LFP signal, biasing activity in the larger nearby neuronal population to appear synchronous and cotuned with these neurons. To address this problem, we used linear filtering techniques to remove features correlated with spike events from LFP recordings. This filtering procedure can be applied for well-isolated single units or multiunit activity. We illustrate the effects of this correction in simulation and on spike data recorded from primary auditory cortex. We find that local spiking activity can explain a significant portion of LFP power at most recording sites and demonstrate that removing the spike-correlated component can affect measurements of auditory tuning of the LFP.

  15. Reducing status quo bias in choice experiments

    DEFF Research Database (Denmark)

    Bonnichsen, Ole; Ladenburg, Jacob

    2015-01-01

    To secure the validity and applicability of stated preference measures in economic analysis, hypothetical preferences must mimic real life preferences. For instance, people have a propensity to prefer what they already have when presented with alternatives that, all things being equal, seem to be...... preferences in our data based on Swedish ostomates’ preferences for ostomy pouch quality changes....

  16. The characteristic of twin-electrode TIG coupling arc pressure

    International Nuclear Information System (INIS)

    Leng Xuesong; Zhang Guangjun; Wu Lin

    2006-01-01

    The coupling arc of twin-electrode TIG (T-TIG) is a particular kind of arc, which is achieved through the coupling of two arcs generated from two insulated electrodes in the same welding torch. It is therefore different from the single arc of conventional TIG in its physical characteristics. This paper studies the distribution of T-TIG coupling arc pressure, and analyses the influences of welding current, arc length, the distance between electrode tips and electrode shape upon arc pressure on the basis of experiment. It is expected that the T-TIG welding method can be applied in high efficiency welding according to its low arc pressure

  17. Lithium manganese oxide spinel electrodes

    Science.gov (United States)

    Darling, Robert Mason

    Batteries based oil intercalation eletrodes are currently being considered for a variety of applications including automobiles. This thesis is concerned with the simulation and experimental investigation of one such system: spinel LiyMn2O4. A mathematical model simulating the behavior of an electrochemical cell containing all intercalation electrode is developed and applied to Li yMn2O4 based systems. The influence of the exchange current density oil the propagation of the reaction through the depth of the electrode is examined theoretically. Galvanostatic cycling and relaxation phenomena on open circuit are simulated for different particle-size distributions. The electrode with uniformly sized particles shows the best performance when the current is on, and relaxes towards equilibrium most quickly. The impedance of a porous electrode containing a particle-size distribution at low frequencies is investigated with all analytic solution and a simplified version of the mathematical model. The presence of the particle-size distribution leads to an apparent diffusion coefficient which has all incorrect concentration dependence. A Li/1 M LiClO4 in propylene carbonate (PC)/ LiyMn 2O4 cell is used to investigate the influence of side reactions oil the current-potential behavior of intercalation electrodes. Slow cyclic voltammograms and self-discharge data are combined to estimate the reversible potential of the host material and the kinetic parameters for the side reaction. This information is then used, together with estimates of the solid-state diffusion coefficient and main-reaction exchange current density, in a mathematical model of the system. Predictions from the model compare favorably with continuous cycling results and galvanostatic experiments with periodic current interruptions. The variation with respect to composition of' the diffusion coefficient of lithium in LiyMn2O4 is estimated from incomplete galvanostatic discharges following open-circult periods. The

  18. Estimation bias and bias correction in reduced rank autoregressions

    DEFF Research Database (Denmark)

    Nielsen, Heino Bohn

    2017-01-01

    This paper characterizes the finite-sample bias of the maximum likelihood estimator (MLE) in a reduced rank vector autoregression and suggests two simulation-based bias corrections. One is a simple bootstrap implementation that approximates the bias at the MLE. The other is an iterative root...

  19. Suppression and excitation of MHD activity with an electrically polarized electrode at the TCABR tokamak plasma edge

    International Nuclear Information System (INIS)

    Nascimento, I.C.; Kuznetsov, Yu.K.; Guimaraes-Filho, Z.O.; Chamaa-Neto, I. El; Usuriaga, O.; Fonseca, A.M.M.; Galvao, R.M.O.; Caldas, I.L.; Severo, J.H.F.; Semenov, I.B.; Ribeiro, C.; Heller, M.V.P.; Bellintani, V.; Elizondo, J.I.; Sanada, E.

    2007-01-01

    Two reproducible regimes of tokamak operation, with excitation or suppression of MHD activity can be obtained using a voltage-biased electrode inside the edge of the TCABR tokamak. The experiment was carried out adjusting the tokamak parameters to obtain two types of discharges: with strong or weak MHD activity, without biasing in both cases. The plasma current was adjusted to cover a range of safety factor from 2.9 up to 3.5, so that when biasing was applied the magnetic island (3,1) could interact with the edge barrier. The application of biasing in subsequent discharges of each type resulted in excitation or suppression of the MHD activity. The results show that the dominant modes are m = 2, n = 1 and m = 3, n = 1 for excitation and partial suppression, respectively. In both regimes a strong decrease in the radial electric field is detected with destruction of the transport barrier and of the improved confinement caused by different mechanisms. The measurements include temporal behaviour of edge transport, turbulence, poloidal electric and magnetic fields, edge density, radial electric fields and radial profile of H α line intensity. The explanation of the excitation and suppression processes is discussed in the paper

  20. Composite carbon foam electrode

    Science.gov (United States)

    Mayer, Steven T.; Pekala, Richard W.; Kaschmitter, James L.

    1997-01-01

    Carbon aerogels used as a binder for granularized materials, including other forms of carbon and metal additives, are cast onto carbon or metal fiber substrates to form composite carbon thin film sheets. The thin film sheets are utilized in electrochemical energy storage applications, such as electrochemical double layer capacitors (aerocapacitors), lithium based battery insertion electrodes, fuel cell electrodes, and electrocapacitive deionization electrodes. The composite carbon foam may be formed by prior known processes, but with the solid particles being added during the liquid phase of the process, i.e. prior to gelation. The other forms of carbon may include carbon microspheres, carbon powder, carbon aerogel powder or particles, graphite carbons. Metal and/or carbon fibers may be added for increased conductivity. The choice of materials and fibers will depend on the electrolyte used and the relative trade off of system resistivty and power to system energy.

  1. Porous electrode preparation method

    Science.gov (United States)

    Arons, R.M.; Dusek, J.T.

    1983-10-18

    A porous sintered plaque is provided with a bimodal porosity that is especially well suited for use as an electrode within a molten carbonate fuel cell. The coarse porosity is sufficient for admitting gases into contact with the reaction surfaces while the fine porosity is wetted with and retains molten electrolyte on the reaction sites. The electrode structure is prepared by providing a very fine powder of such as nickel oxide and blending the powder with a suitable decomposable binder to form a solid mass. The mass is comminuted into agglomerate size particles substantially larger than the fine oxide particles and formed into a cohesive compact for subsequent sintering. Sintering is carried out at sufficient conditions to bind the agglomerates together into a porous structure having both coarse and fine porosity. Where lithiated nickel oxide cathodes are prepared, the sintering conditions can be moderate enough to retain substantial quantities of lithium within the electrode for adequate conductivity. 2 figs.

  2. Ratio Bias and Policy Preferences

    DEFF Research Database (Denmark)

    Pedersen, Rasmus Tue

    2017-01-01

    Numbers permeate modern political communication. While current scholarship on framing effects has focused on the persuasive effects of words and arguments, this article shows that framing of numbers can also substantially affect policy preferences. Such effects are caused by ratio bias, which...... is a general tendency to focus on numerators and pay insufficient attention to denominators in ratios. Using a population-based survey experiment, I demonstrate how differently framed but logically equivalent representations of the exact same numerical value can have large effects on citizens’ preferences...... regarding salient political issues such as education and taxes. Furthermore, the effects of numerical framing are found across most groups of the population, largely regardless of their political predisposition and their general ability to understand and use numerical information. These findings have...

  3. Sandwich-type electrode

    Science.gov (United States)

    Lu, Wen-Tong P.; Garcia, Earl R.

    1983-01-01

    Disclosed is an improvement on a method of making an electrode wherein a suspension in a liquid is prepared of a powdered catalyst containing a noble metal, carbon powder and a binder, and the suspension is poured over a carbon substrate dried, compressed and sintered to form a solid catalyst layer bonded to the carbon substrate. The improvement is placing a carbon paper on the catalyst layer prior to compressing. The improved electrode can be used as either a cathode or an anode in a sulfur dioxide depolarized electrolyzer in a process for producing hydrogen from water.

  4. Single Electrode Heat Effects

    DEFF Research Database (Denmark)

    Jacobsen, Torben; Broers, G. H. J.

    1977-01-01

    The heat evolution at a single irreversibly working electrode is treated onthe basis of the Brønsted heat principle. The resulting equation is analogous to the expression for the total heat evolution in a galvanic cellwith the exception that –DeltaS is substituted by the Peltier entropy, Delta......SP, of theelectrode reaction. eta is the overvoltage at the electrode. This equation is appliedto a high temperature carbonate fuel cell. It is shown that the Peltier entropyterm by far exceeds the heat production due to the irreversible losses, and thatthe main part of heat evolved at the cathode is reabsorbed...

  5. Evaluation of niobium as candidate electrode material for dc high voltage photoelectron guns

    Directory of Open Access Journals (Sweden)

    M. BastaniNejad

    2012-08-01

    Full Text Available The field emission characteristics of niobium electrodes were compared to those of stainless steel electrodes using a DC high voltage field emission test apparatus. A total of eight electrodes were evaluated: two 304 stainless steel electrodes polished to mirrorlike finish with diamond grit and six niobium electrodes (two single-crystal, two large-grain, and two fine-grain that were chemically polished using a buffered-chemical acid solution. Upon the first application of high voltage, the best large-grain and single-crystal niobium electrodes performed better than the best stainless steel electrodes, exhibiting less field emission at comparable voltage and field strength. In all cases, field emission from electrodes (stainless steel and/or niobium could be significantly reduced and sometimes completely eliminated, by introducing krypton gas into the vacuum chamber while the electrode was biased at high voltage. Of all the electrodes tested, a large-grain niobium electrode performed the best, exhibiting no measurable field emission (<10  pA at 225 kV with 20 mm cathode/anode gap, corresponding to a field strength of 18.7  MV/m.

  6. Evaluation of Niobium as Candidate Electrode Material for DC High Voltage Photoelectron Guns

    Science.gov (United States)

    BastaniNejad, M.; Mohamed, Abdullah; Elmustafa, A. A.; Adderley, P.; Clark, J.; Covert, S.; Hansknecht, J.; Hernandez-Garcia, C.; Poelker, M.; Mammei, R.; hide

    2012-01-01

    The field emission characteristics of niobium electrodes were compared to those of stainless steel electrodes using a DC high voltage field emission test apparatus. A total of eight electrodes were evaluated: two 304 stainless steel electrodes polished to mirror-like finish with diamond grit and six niobium electrodes (two single-crystal, two large-grain, and two fine-grain) that were chemically polished using a buffered-chemical acid solution. Upon the first application of high voltage, the best large-grain and single-crystal niobium electrodes performed better than the best stainless steel electrodes, exhibiting less field emission at comparable voltage and field strength. In all cases, field emission from electrodes (stainless steel and/or niobium) could be significantly reduced and sometimes completely eliminated, by introducing krypton gas into the vacuum chamber while the electrode was biased at high voltage. Of all the electrodes tested, a large-grain niobium electrode performed the best, exhibiting no measurable field emission (< 10 pA) at 225 kV with 20 mm cathode/anode gap, corresponding to a field strength of 18:7 MV/m.

  7. Internal bias field in glycine phosphite crystal

    International Nuclear Information System (INIS)

    Nayeem, Jannatul; Wakabayashi, Hiroshi; Kikuta, Toshio; Yamazaki, Toshinari; Nakatani, Noriyuki

    2003-01-01

    The distributions of internal bias field E b have been investigated under the carbon-powder pattern and mercury electrode techniques in GPI ferroelectric crystals. Polarity and intensity of E b are distributed depending on crystal growth sectors. Crystal symmetry 2/m is observed obviously in the distribution of E b . The polarities of E b are head-to-head manner in those growth sectors where a surface is growing parallel to the crystallographic a-axis and tail-to-tail manner in the other growth sectors in the crystal. The maximum intensity of E b is found in the sectors (010) where the growing surfaces are perpendicular to the ferroelectric b-axis

  8. Impact of Selection Bias on Estimation of Subsequent Event Risk

    NARCIS (Netherlands)

    Hu, Yi Juan; Schmidt, Amand F.; Dudbridge, Frank; Holmes, Michael V; Brophy, James M.; Tragante, Vinicius; Li, Ziyi; Liao, Peizhou; Quyyumi, Arshed A.; McCubrey, Raymond O.; Horne, Benjamin D.; Hingorani, Aroon D; Asselbergs, Folkert W; Patel, Riyaz S.; Long, Qi; Åkerblom, Axel; Algra, Ale; Allayee, Hooman; Almgren, Peter; Anderson, Jeffrey L.; Andreassi, Maria G.; Anselmi, Chiara V.; Ardissino, Diego; Arsenault, Benoit J.; Ballantyne, Christie M.; Baranova, Ekaterina V.; Behloui, Hassan; Bergmeijer, Thomas O; Bezzina, Connie R; Bjornsson, Eythor; Body, Simon C.; Boeckx, Bram; Boersma, Eric H.; Boerwinkle, Eric; Bogaty, Peter; Braund, Peter S; Breitling, Lutz P.; Brenner, Hermann; Briguori, Carlo; Brugts, Jasper J.; Burkhardt, Ralph; Cameron, Vicky A.; Carlquist, John F.; Carpeggiani, Clara; Carruthers, Kathryn F.; Casu, Gavino; Condorelli, Gianluigi; Cresci, Sharon; Danchin, Nicolas; de Faire, Ulf; Deanfield, John; Delgado, Graciela; Deloukas, Panos; Direk, Kenan; Doughty, Robert N.; Drexel, Heinz; Duarte, Nubia E.; Dubé, Marie Pierre; Dufresne, Line; Engert, James C; Eriksson, Niclas; Fitzpatrick, Natalie; Foco, Luisa; Ford, Ian; Fox, Keith A; Gigante, Bruna; Gijsberts, Crystel M.; Girelli, Domenico; Gong, Yan; Gudbjartsson, Daniel F.; Hagström, Emil; Hartiala, Jaana; Hazen, Stanley L.; Held, Claes; Helgadottir, Anna; Hemingway, Harry; Heydarpour, Mahyar; Hoefer, Imo E.; Hovingh, G. Kees; Hubacek, Jaroslav A; James, Stefan; Johnson, Julie A; Jukema, J Wouter; Kaczor, Marcin P.; Kaminski, Karol A.; Kettner, Jiri; Kiliszek, Marek; Kleber, Marcus; Klungel, Olaf H.; Kofink, Daniel; Kohonen, Mika; Kotti, Salma; Kuukasjärvi, Pekka; Lagerqvist, Bo; Lambrechts, Diether; Lang, Chim C; Laurikka, Jari O.; Leander, Karin; Lee, Vei Vei; Lehtimäki, Terho; Leiherer, Andreas; Lenzini, Petra A.; Levin, Daniel; Lindholm, Daniel; Lokki, Marja-Liisa; Lotufo, Paulo A; Lyytikäinen, Leo-Pekka; Mahmoodi, B. Khan; Maitland-Van Der Zee, Anke H.; Martinelli, Nicola; März, Winfried; Marziliano, Nicola; McPherson, Ruth; Melander, Olle; Mons, Ute; Muehlschlegel, Jochen D.; Muhlestein, Joseph B.; Nelson, Cristopher P.; Cheh, Chris Newton; Olivieri, Oliviero; Opolski, Grzegorz; Palmer, Colin Na; Pare, Guillaume; Pasterkamp, Gerard; Pepine, Carl J; Pepinski, Witold; Pereira, Alexandre C.; Pilbrow, Anna P.; Pilote, Louise; Pitha, Jan; Ploski, Rafal; Richards, A. Mark; Saely, Christoph H.; Samani, Nilesh J; Samman-Tahhan, Ayman; Sanak, Marek; Sandesara, Pratik B.; Sattar, Naveed; Scholz, Markus; Siegbahn, Agneta; Simon, Tabassome; Sinisalo, Juha; Smith, J. Gustav; Spertus, John A.; Stefansson, Kari; Stewart, Alexandre F R; Stott, David J.; Szczeklik, Wojciech; Szpakowicz, Anna; Tanck, Michael W.T.; Tang, Wilson H.; Tardif, Jean-Claude; Ten Berg, Jur M.; Teren, Andrej; Thanassoulis, George; Thiery, Joachim; Thorgeirsson, Gudmundur; Thorleifsson, Gudmar; Thorsteinsdottir, Unnur; Timmis, Adam; Trompet, Stella; Van de Werf, Frans; van der Graaf, Yolanda; Van Der Haarst, Pim; van der Laan, Sander W; Vilmundarson, Ragnar O.; Virani, Salim S.; Visseren, Frank L J; Vlachopoulou, Efthymia; Wallentin, Lars; Waltenberger, Johannes; Wauters, Els; Wilde, Arthur A M

    2017-01-01

    Background - Studies of recurrent or subsequent disease events may be susceptible to bias caused by selection of subjects who both experience and survive the primary indexing event. Currently, the magnitude of any selection bias, particularly for subsequent time-to-event analysis in genetic

  9. A retrieval-based approach to eliminating hindsight bias.

    Science.gov (United States)

    Van Boekel, Martin; Varma, Keisha; Varma, Sashank

    2017-03-01

    Individuals exhibit hindsight bias when they are unable to recall their original responses to novel questions after correct answers are provided to them. Prior studies have eliminated hindsight bias by modifying the conditions under which original judgments or correct answers are encoded. Here, we explored whether hindsight bias can be eliminated by manipulating the conditions that hold at retrieval. Our retrieval-based approach predicts that if the conditions at retrieval enable sufficient discrimination of memory representations of original judgments from memory representations of correct answers, then hindsight bias will be reduced or eliminated. Experiment 1 used the standard memory design to replicate the hindsight bias effect in middle-school students. Experiments 2 and 3 modified the retrieval phase of this design, instructing participants beforehand that they would be recalling both their original judgments and the correct answers. As predicted, this enabled participants to form compound retrieval cues that discriminated original judgment traces from correct answer traces, and eliminated hindsight bias. Experiment 4 found that when participants were not instructed beforehand that they would be making both recalls, they did not form discriminating retrieval cues, and hindsight bias returned. These experiments delineate the retrieval conditions that produce-and fail to produce-hindsight bias.

  10. The Role of Biased Scanning in Counterattitudinal Advocacy

    Science.gov (United States)

    Cunningham, John D.; Collins, Barry E.

    1977-01-01

    Experiments tested biased-scanning hypothesis that high financial inducement leads to greater cognitive contact with counterattitudinal arguments and thus to greater attitude change. No differences in biased scanning or attitude change were observed as a function of financial inducement. Results were interpreted in framework of reactance and…

  11. Virtual electrodes for high-density electrode arrays

    Science.gov (United States)

    Cela, Carlos J.; Lazzi, Gianluca

    2015-10-13

    The present embodiments are directed to implantable electrode arrays having virtual electrodes. The virtual electrodes may improve the resolution of the implantable electrode array without the burden of corresponding complexity of electronic circuitry and wiring. In a particular embodiment, a virtual electrode may include one or more passive elements to help steer current to a specific location between the active electrodes. For example, a passive element may be a metalized layer on a substrate that is adjacent to, but not directly connected to an active electrode. In certain embodiments, an active electrode may be directly coupled to a power source via a conductive connection. Beneficially, the passive elements may help to increase the overall resolution of the implantable array by providing additional stimulation points without requiring additional wiring or driver circuitry for the passive elements.

  12. Recognition bias and the physical attractiveness stereotype.

    Science.gov (United States)

    Rohner, Jean-Christophe; Rasmussen, Anders

    2012-06-01

    Previous studies have found a recognition bias for information consistent with the physical attractiveness stereotype (PAS), in which participants believe that they remember that attractive individuals have positive qualities and that unattractive individuals have negative qualities, regardless of what information actually occurred. The purpose of this research was to examine whether recognition bias for PAS congruent information is replicable and invariant across a variety of conditions (i.e. generalizable). The effects of nine different moderator variables were examined in two experiments. With a few exceptions, the effect of PAS congruence on recognition bias was independent of the moderator variables. The results suggest that the tendency to believe that one remembers information consistent with the physical attractiveness stereotype is a robust phenomenon. © 2012 The Authors. Scandinavian Journal of Psychology © 2012 The Scandinavian Psychological Associations.

  13. Motion, identity and the bias toward agency

    Directory of Open Access Journals (Sweden)

    Chris eFields

    2014-08-01

    Full Text Available The well-documented human bias toward agency as a cause and therefore an explanation of observed events is typically attributed to evolutionary selection for a social brain. Based on a review of developmental and adult behavioral and neurocognitive data, it is argued that the bias toward agency is a result of the default human solution, developed during infancy, to the computational requirements of object re-identification over gaps in observation of more than a few seconds. If this model is correct, overriding the bias toward agency to construct mechanistic explanations of observed events requires structure-mapping inferences, implemented by the pre-motor action planning system, that replace agents with mechanisms as causes of unobserved changes in contextual or featural properties of objects. Experiments that would test this model are discussed.

  14. Attentional bias for craving-related (chocolate) food cues.

    Science.gov (United States)

    Kemps, Eva; Tiggemann, Marika

    2009-12-01

    In this study, we investigated attentional biases for craving-related food cues. A pictorial dot probe task was used to assess selective attentional processing of one particular highly desired food, namely chocolate, relative to that of other highly desired foods. In Experiment 1, we examined biased processing of chocolate cues in habitual (trait) chocolate cravers, whereas in Experiment 2 we investigated the effect of experimentally induced (state) chocolate cravings on such processing. As predicted, habitual chocolate cravers (Experiment 1) and individuals in whom a craving for chocolate was temporarily induced (Experiment 2) showed speeded detection of probes replacing chocolate-related pictures, demonstrating an attentional bias for chocolate cues. Subsequent examination indicated that in both experiments the observed attentional biases stemmed from difficulty in disengaging attention from chocolate cues rather than from a shift of attention toward such cues. The findings have important theoretical and practical implications.

  15. Confinement of nonneutral spheroidal plasmas in multi-ring electrode traps

    International Nuclear Information System (INIS)

    Mohri, Akihiro; Yuyama, Tetsumori; Michishita, Toshinori; Higaki, Hiroyuki; Tanaka, Hitoshi; Yamazawa, Yohei; Aoyagi, Masayuki

    1998-01-01

    A nonneutral spheroidal plasma can be settled in a rigid rotor equilibrium inside a closed conducting cell independently of induced image charges on the cell wall if the electrostatic potential distribution on the wall surface is set equal to the sum of the external hyperbolic potential (r 2 -2z 2 ) and the self-potential produced by the plasma. A confinement system equipped with a train of properly biased ring electrodes can approximately generate any axisymmetric potential, including the above field. Experiments on confinement of electron spheroids in such a system showed that the confinement time became the longest when the condition to diminish the image charge effects was satisfied. The observed frequency of the centre-of-mass harmonic oscillation of the plasma in this configuration was in good agreement with the estimated one. (author)

  16. Raman mapping and in situ SERS spectroelectrochemical studies of 6-mercaptopurine SAMs on the gold electrode.

    Science.gov (United States)

    Yang, Haifeng; Liu, Yanli; Liu, Zhimin; Yang, Yu; Jiang, Jianhui; Zhang, Zongrang; Shen, Guoli; Yu, Ruqin

    2005-02-24

    The self-assembled monolayers (SAMs) of 6-mercaptopurine (6MP) were formed at the roughened polycrystalline gold surfaces in acid and alkaline media. The time-dependent Raman mapping spectral analysis in conjunction with the quantum calculations for the vibrational modes using ab initio BLYP/6-31G method suggested that both of the resulted 6MP SAMs adopted the same adsorption mode through the S atom of pyrimidine moiety and the N7 atom of the imidazole moiety anchoring the gold surface in a vertical way. The in situ surface-enhanced Raman scattering spectroelectrochemical experiment was conducted to examine the stability of the SAMs at various bias potentials. It was found that the detaching process of the 6MP SAMs from the surface involved one electron reduction as the voltage was applied at ca. 0.7 V vs a standard calomel electrode.

  17. High Efficient THz Emission From Unbiased and Biased Semiconductor Nanowires Fabricated Using Electron Beam Lithography

    Energy Technology Data Exchange (ETDEWEB)

    Balci, Soner; Czaplewski, David A.; Jung, Il Woong; Kim, Ju-Hyung; Hatami, Fariba; Kung, Patrick; Kim, Seongsin Margaret

    2017-07-01

    Besides having perfect control on structural features, such as vertical alignment and uniform distribution by fabricating the wires via e-beam lithography and etching process, we also investigated the THz emission from these fabricated nanowires when they are applied DC bias voltage. To be able to apply a voltage bias, an interdigitated gold (Au) electrode was patterned on the high-quality InGaAs epilayer grown on InP substrate bymolecular beam epitaxy. Afterwards, perfect vertically aligned and uniformly distributed nanowires were fabricated in between the electrodes of this interdigitated pattern so that we could apply voltage bias to improve the THz emission. As a result, we achieved enhancement in the emitted THz radiation by ~four times, about 12 dB increase in power ratio at 0.25 THz with a DC biased electric field compared with unbiased NWs.

  18. Altering attentional control settings causes persistent biases of visual attention.

    Science.gov (United States)

    Knight, Helen C; Smith, Daniel T; Knight, David C; Ellison, Amanda

    2016-01-01

    Attentional control settings have an important role in guiding visual behaviour. Previous work within cognitive psychology has found that the deployment of general attentional control settings can be modulated by training. However, research has not yet established whether long-term modifications of one particular type of attentional control setting can be induced. To address this, we investigated persistent alterations to feature search mode, also known as an attentional bias, towards an arbitrary stimulus in healthy participants. Subjects were biased towards the colour green by an information sheet. Attentional bias was assessed using a change detection task. After an interval of either 1 or 2 weeks, participants were then retested on the same change detection task, tested on a different change detection task where colour was irrelevant, or were biased towards an alternative colour. One experiment included trials in which the distractor stimuli (but never the target stimuli) were green. The key finding was that green stimuli in the second task attracted attention, despite this impairing task performance. Furthermore, inducing a second attentional bias did not override the initial bias toward green objects. The attentional bias also persisted for at least two weeks. It is argued that this persistent attentional bias is mediated by a chronic change to participants' attentional control settings, which is aided by long-term representations involving contextual cueing. We speculate that similar changes to attentional control settings and continuous cueing may relate to attentional biases observed in psychopathologies. Targeting these biases may be a productive approach to treatment.

  19. Protected electrodes for plasma panels

    International Nuclear Information System (INIS)

    Hall, S.W.

    1984-01-01

    A metal oxide coating is applied between the conductive base and the magnesium oxide dielectric of the input and/or erase electrode(s) in a plasma display device to prevent break-down of the dielectric

  20. Transparent electrodes in the terahertz regime – a new approach

    DEFF Research Database (Denmark)

    Malureanu, Radu; Song, Z.; Zalkovskij, Maksim

    We suggest a new possibility for obtaining a transparent metallic film, thus allowing for completely transparent electrodes. By placing a complementary composite layer on top of the electrode, we can cancel the back-scattering of the latter thus obtaining a perfectly transparent structure. For ea...... of fabrication, we performed the first experiments in the THz regime, but the concept is applicable to the entire electromagnetic waves spectrum. We show that the experiments and theory match each other perfectly....

  1. Ion-selective electrode reviews

    CERN Document Server

    Thomas, J D R

    1985-01-01

    Ion-Selective Electrode Reviews, Volume 7 is a collection of papers that covers the applications of electrochemical sensors, along with the versatility of ion-selective electrodes. The coverage of the text includes solid contact in membrane ion-selective electrodes; immobilized enzyme probes for determining inhibitors; potentiometric titrations based on ion-pair formation; and application of ion-selective electrodes in soil science, kinetics, and kinetic analysis. The text will be of great use to chemists and chemical engineers.

  2. Ceramic carbon electrode-based anodes for use in the Cu-Cl thermochemical cycle

    Energy Technology Data Exchange (ETDEWEB)

    Ranganathan, Santhanam; Easton, E. Bradley [Faculty of Science, University of Ontario Institute of Technology, 2000 Simcoe Street North, Oshawa, Ontario (Canada)

    2010-05-15

    We have investigated CCE materials prepared using 3-aminopropyl trimethoxysilane. Electrochemical experiments were performed to characterize their suitability as anode electrode materials for use in the electrochemical step of the Cu-Cl thermochemical cycle. CCE-based electrodes vastly outperform a bare carbon electrode. Optimization of the organosilicate loading revealed maximum electrode performance was achieved with 36 wt% and was explained in terms of the optimal balance of active area and anion transport properties. (author)

  3. Visual attention and the neuroimage bias.

    Directory of Open Access Journals (Sweden)

    D A Baker

    Full Text Available Several highly-cited experiments have presented evidence suggesting that neuroimages may unduly bias laypeople's judgments of scientific research. This finding has been especially worrisome to the legal community in which neuroimage techniques may be used to produce evidence of a person's mental state. However, a more recent body of work that has looked directly at the independent impact of neuroimages on layperson decision-making (both in legal and more general arenas, and has failed to find evidence of bias. To help resolve these conflicting findings, this research uses eye tracking technology to provide a measure of attention to different visual representations of neuroscientific data. Finding an effect of neuroimages on the distribution of attention would provide a potential mechanism for the influence of neuroimages on higher-level decisions. In the present experiment, a sample of laypeople viewed a vignette that briefly described a court case in which the defendant's actions might have been explained by a neurological defect. Accompanying these vignettes was either an MRI image of the defendant's brain, or a bar graph depicting levels of brain activity-two competing visualizations that have been the focus of much of the previous research on the neuroimage bias. We found that, while laypeople differentially attended to neuroimagery relative to the bar graph, this did not translate into differential judgments in a way that would support the idea of a neuroimage bias.

  4. Nonequilibrium Kondo effect by the equilibrium numerical renormalization group method: The hybrid Anderson model subject to a finite spin bias

    Science.gov (United States)

    Fang, Tie-Feng; Guo, Ai-Min; Sun, Qing-Feng

    2018-06-01

    We investigate Kondo correlations in a quantum dot with normal and superconducting electrodes, where a spin bias voltage is applied across the device and the local interaction U is either attractive or repulsive. When the spin current is blockaded in the large-gap regime, this nonequilibrium strongly correlated problem maps into an equilibrium model solvable by the numerical renormalization group method. The Kondo spectra with characteristic splitting due to the nonequilibrium spin accumulation are thus obtained at high precision. It is shown that while the bias-induced decoherence of the spin Kondo effect is partially compensated by the superconductivity, the charge Kondo effect is enhanced out of equilibrium and undergoes an additional splitting by the superconducting proximity effect, yielding four Kondo peaks in the local spectral density. In the charge Kondo regime, we find a universal scaling of charge conductance in this hybrid device under different spin biases. The universal conductance as a function of the coupling to the superconducting lead is peaked at and hence directly measures the Kondo temperature. Our results are of direct relevance to recent experiments realizing a negative-U charge Kondo effect in hybrid oxide quantum dots [Nat. Commun. 8, 395 (2017), 10.1038/s41467-017-00495-7].

  5. Exchange bias theory

    International Nuclear Information System (INIS)

    Kiwi, Miguel

    2001-01-01

    Research on the exchange bias (EB) phenomenon has witnessed a flurry of activity during recent years, which stems from its use in magnetic sensors and as stabilizers in magnetic reading heads. EB was discovered in 1956 but it attracted only limited attention until these applications, closely related to giant magnetoresistance, were developed during the last decade. In this review, I initially give a short introduction, listing the most salient experimental results and what is required from an EB theory. Next, I indicate some of the obstacles in the road towards a satisfactory understanding of the phenomenon. The main body of the text reviews and critically discusses the activity that has flourished, mainly during the last 5 years, in the theoretical front. Finally, an evaluation of the progress made, and a critical assessment as to where we stand nowadays along the road to a satisfactory theory, is presented

  6. Bias modification training can alter approach bias and chocolate consumption.

    Science.gov (United States)

    Schumacher, Sophie E; Kemps, Eva; Tiggemann, Marika

    2016-01-01

    Recent evidence has demonstrated that bias modification training has potential to reduce cognitive biases for attractive targets and affect health behaviours. The present study investigated whether cognitive bias modification training could be applied to reduce approach bias for chocolate and affect subsequent chocolate consumption. A sample of 120 women (18-27 years) were randomly assigned to an approach-chocolate condition or avoid-chocolate condition, in which they were trained to approach or avoid pictorial chocolate stimuli, respectively. Training had the predicted effect on approach bias, such that participants trained to approach chocolate demonstrated an increased approach bias to chocolate stimuli whereas participants trained to avoid such stimuli showed a reduced bias. Further, participants trained to avoid chocolate ate significantly less of a chocolate muffin in a subsequent taste test than participants trained to approach chocolate. Theoretically, results provide support for the dual process model's conceptualisation of consumption as being driven by implicit processes such as approach bias. In practice, approach bias modification may be a useful component of interventions designed to curb the consumption of unhealthy foods. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. Ion-selective electrode reviews

    CERN Document Server

    Thomas, J D R

    1983-01-01

    Ion-Selective Electrode Reviews, Volume 5 is a collection of articles that covers ion-speciation. The book aims to present the advancements of the range and capabilities of selective ion-sensors. The topics covered in the selection are neutral carrier based ion-selective electrodes; reference electrodes and liquid junction effects in ion-selective electrode potentiometry; ion transfer across water/organic phase boundaries and analytical; and carbon substrate ion-selective electrodes. The text will be of great use to chemists and chemical engineers.

  8. Biasing of Capacitive Micromachined Ultrasonic Transducers.

    Science.gov (United States)

    Caliano, Giosue; Matrone, Giulia; Savoia, Alessandro Stuart

    2017-02-01

    Capacitive micromachined ultrasonic transducers (CMUTs) represent an effective alternative to piezoelectric transducers for medical ultrasound imaging applications. They are microelectromechanical devices fabricated using silicon micromachining techniques, developed in the last two decades in many laboratories. The interest for this novel transducer technology relies on its full compatibility with standard integrated circuit technology that makes it possible to integrate on the same chip the transducers and the electronics, thus enabling the realization of extremely low-cost and high-performance devices, including both 1-D or 2-D arrays. Being capacitive transducers, CMUTs require a high bias voltage to be properly operated in pulse-echo imaging applications. The typical bias supply residual ripple of high-quality high-voltage (HV) generators is in the millivolt range, which is comparable with the amplitude of the received echo signals, and it is particularly difficult to minimize. The aim of this paper is to analyze the classical CMUT biasing circuits, highlighting the features of each one, and to propose two novel HV generator architectures optimized for CMUT biasing applications. The first circuit proposed is an ultralow-residual ripple (generator that uses an extremely stable sinusoidal power oscillator topology. The second circuit employs a commercially available integrated step-up converter characterized by a particularly efficient switching topology. The circuit is used to bias the CMUT by charging a buffer capacitor synchronously with the pulsing sequence, thus reducing the impact of the switching noise on the received echo signals. The small area of the circuit (about 1.5 cm 2 ) makes it possible to generate the bias voltage inside the probe, very close to the CMUT, making the proposed solution attractive for portable applications. Measurements and experiments are shown to demonstrate the effectiveness of the new approaches presented.

  9. Liberal bias and the five-factor model.

    Science.gov (United States)

    Charney, Evan

    2015-01-01

    Duarte et al. draw attention to the "embedding of liberal values and methods" in social psychological research. They note how these biases are often invisible to the researchers themselves. The authors themselves fall prey to these "invisible biases" by utilizing the five-factor model of personality and the trait of openness to experience as one possible explanation for the under-representation of political conservatives in social psychology. I show that the manner in which the trait of openness to experience is conceptualized and measured is a particularly blatant example of the very liberal bias the authors decry.

  10. Control of secondary electrons from ion beam impact using a positive potential electrode

    Energy Technology Data Exchange (ETDEWEB)

    Crowley, T. P., E-mail: tpcrowley@xanthotechnologies.com; Demers, D. R.; Fimognari, P. J. [Xantho Technologies, LLC, Madison, Wisconsin 53705 (United States)

    2016-11-15

    Secondary electrons emitted when an ion beam impacts a detector can amplify the ion beam signal, but also introduce errors if electrons from one detector propagate to another. A potassium ion beam and a detector comprised of ten impact wires, four split-plates, and a pair of biased electrodes were used to demonstrate that a low-voltage, positive electrode can be used to maintain the beneficial amplification effect while greatly reducing the error introduced from the electrons traveling between detector elements.

  11. Electrostatic Levitator Electrode Layout

    Science.gov (United States)

    1998-01-01

    Schematic of Electrostatic Levitator (ESL) electrodes and controls system. The ESL uses static electricity to suspend an object (about 2-3 mm in diameter) inside a vacuum chamber while a laser heats the sample until it melts. This lets scientists record a wide range of physical properties without the sample contacting the container or any instruments, conditions that would alter the readings. The Electrostatic Levitator is one of several tools used in NASA's microgravity materials science program.

  12. On the hydrophilicity of electrodes for capacitive energy extraction

    International Nuclear Information System (INIS)

    Lian, Cheng; East China University of Science and Technology, Shanghai; Kong, Xian; Tsinghua University, Beijing; Liu, Honglai; Wu, Jianzhong

    2016-01-01

    The so-called Capmix technique for energy extraction is based on the cyclic expansion of electrical double layers to harvest dissipative energy arising from the salinity difference between freshwater and seawater. Its optimal performance requires a careful selection of the electrical potentials for the charging and discharging processes, which must be matched with the pore characteristics of the electrode materials. While a number of recent studies have examined the effects of the electrode pore size and geometry on the capacitive energy extraction processes, there is little knowledge on how the surface properties of the electrodes affect the thermodynamic efficiency. In this paper, we investigate the Capmix processes using the classical density functional theory for a realistic model of electrolyte solutions. The theoretical predictions allow us to identify optimal operation parameters for capacitive energy extraction with porous electrodes of different surface hydrophobicity. Finally, in agreement with recent experiments, we find that the thermodynamic efficiency can be much improved by using most hydrophilic electrodes.

  13. Religious Attitudes and Home Bias

    OpenAIRE

    C. Reggiani; G. Rossini

    2008-01-01

    Home bias affects trade in goods, services and financial assets. It is mostly generated by "natural" trade barriers. Among these dividers we may list many behavioral and sociological factors, such as status quo biases and a few kind of ‘embeddedness’. Unfortunately these factors are difficult to measure. An important part of ‘embeddedness’ may be related to religious attitudes. Is there any relation between economic home bias and religious attitudes at the individual tier? Our aim is to provi...

  14. Flexible transparent electrode

    Science.gov (United States)

    Demiryont, Hulya; Shannon, Kenneth C., III; Moorehead, David; Bratcher, Matthew

    2011-06-01

    This paper presents the properties of the EclipseTECTM transparent conductor. EclipseTECTM is a room temperature deposited nanostructured thin film coating system comprised of metal-oxide semiconductor elements. The system possesses metal-like conductivity and glass-like transparency in the visible region. These highly conductive TEC films exhibit high shielding efficiency (35dB at 1 to 100GHz). EclipseTECTM can be deposited on rigid or flexible substrates. For example, EclipseTECTM deposited on polyethylene terephthalate (PET) is extremely flexible that can be rolled around a 9mm diameter cylinder with little or no reduction in electrical conductivity and that can assume pre-extension states after an applied stress is relieved. The TEC is colorless and has been tailored to have high visible transmittance which matches the eye sensitivity curve and allows the viewing of true background colors through the coating. EclipseTECTM is flexible, durable and can be tailored at the interface for applications such as electron- or hole-injecting OLED electrodes as well as electrodes in flexible displays. Tunable work function and optical design flexibility also make EclipseTECTM well-suited as a candidate for grid electrode replacement in next-generation photovoltaic cells.

  15. Bias in clinical intervention research

    DEFF Research Database (Denmark)

    Gluud, Lise Lotte

    2006-01-01

    Research on bias in clinical trials may help identify some of the reasons why investigators sometimes reach the wrong conclusions about intervention effects. Several quality components for the assessment of bias control have been suggested, but although they seem intrinsically valid, empirical...... evidence is needed to evaluate their effects on the extent and direction of bias. This narrative review summarizes the findings of methodological studies on the influence of bias in clinical trials. A number of methodological studies suggest that lack of adequate randomization in published trial reports...

  16. 3 keys to defeating unconscious bias watch, think, act

    CERN Document Server

    Thiederman, Sondra

    2015-01-01

    Have you ever had a biased thought? If the answer is “yes,” join the club. Everybody has biases and, although that doesn’t make us bad people, it does mean we compromise our ability to get along with people who are different from us. The good news is, there’s a lot we can do to defeat bias. Calling on Dr. Sondra Thiederman’s twenty-five years of experience in the diversity/inclusion field, the book lays out an innovative WATCH, THINK, ACT strategy that each of us can immediately apply to the task. Easy-to-read and filled with anecdotes and activities, 3 Keys shows the reader: • How to WATCH their thoughts, experiences, and actions to identify unconscious biases and target them for extinction. • How to THINK in such a way as to weaken and control our biases. • How to ACT to defeat our biases and cultivate the kind of common ground that we know to be inhospitable to the survival of bias. Designed to motivate real change, the answer to defeating our biases is in these pages. The rest is up to you...

  17. Automation bias: empirical results assessing influencing factors.

    Science.gov (United States)

    Goddard, Kate; Roudsari, Abdul; Wyatt, Jeremy C

    2014-05-01

    To investigate the rate of automation bias - the propensity of people to over rely on automated advice and the factors associated with it. Tested factors were attitudinal - trust and confidence, non-attitudinal - decision support experience and clinical experience, and environmental - task difficulty. The paradigm of simulated decision support advice within a prescribing context was used. The study employed within participant before-after design, whereby 26 UK NHS General Practitioners were shown 20 hypothetical prescribing scenarios with prevalidated correct and incorrect answers - advice was incorrect in 6 scenarios. They were asked to prescribe for each case, followed by being shown simulated advice. Participants were then asked whether they wished to change their prescription, and the post-advice prescription was recorded. Rate of overall decision switching was captured. Automation bias was measured by negative consultations - correct to incorrect prescription switching. Participants changed prescriptions in 22.5% of scenarios. The pre-advice accuracy rate of the clinicians was 50.38%, which improved to 58.27% post-advice. The CDSS improved the decision accuracy in 13.1% of prescribing cases. The rate of automation bias, as measured by decision switches from correct pre-advice, to incorrect post-advice was 5.2% of all cases - a net improvement of 8%. More immediate factors such as trust in the specific CDSS, decision confidence, and task difficulty influenced rate of decision switching. Lower clinical experience was associated with more decision switching. Age, DSS experience and trust in CDSS generally were not significantly associated with decision switching. This study adds to the literature surrounding automation bias in terms of its potential frequency and influencing factors. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  18. Information environment, behavioral biases, and home bias in analysts’ recommendations

    DEFF Research Database (Denmark)

    Farooq, Omar; Taouss, Mohammed

    2012-01-01

    Can information environment of a firm explain home bias in analysts’ recommendations? Can the extent of agency problems explain optimism difference between foreign and local analysts? This paper answers these questions by documenting the effect of information environment on home bias in analysts’...

  19. Threat bias, not negativity bias, underpins differences in political ideology.

    Science.gov (United States)

    Lilienfeld, Scott O; Latzman, Robert D

    2014-06-01

    Although disparities in political ideology are rooted partly in dispositional differences, Hibbing et al.'s analysis paints with an overly broad brush. Research on the personality correlates of liberal-conservative differences points not to global differences in negativity bias, but to differences in threat bias, probably emanating from differences in fearfulness. This distinction bears implications for etiological research and persuasion efforts.

  20. Bias voltage induced resistance switching effect in single-molecule magnets' tunneling junction.

    Science.gov (United States)

    Zhang, Zhengzhong; Jiang, Liang

    2014-09-12

    An electric-pulse-induced reversible resistance change effect in a molecular magnetic tunneling junction, consisting of a single-molecule magnet (SMM) sandwiched in one nonmagnetic and one ferromagnetic electrode, is theoretically investigated. By applying a time-varying bias voltage, the SMM's spin orientation can be manipulated with large bias voltage pulses. Moreover, the different magnetic configuration at high-resistance/low-resistance states can be 'read out' by utilizing relative low bias voltage. This device scheme can be implemented with current technologies (Khajetoorians et al 2013 Science 339 55) and has potential application in molecular spintronics and high-density nonvolatile memory devices.

  1. Bias voltage induced resistance switching effect in single-molecule magnets’ tunneling junction

    Science.gov (United States)

    Zhang, Zhengzhong; Jiang, Liang

    2014-09-01

    An electric-pulse-induced reversible resistance change effect in a molecular magnetic tunneling junction, consisting of a single-molecule magnet (SMM) sandwiched in one nonmagnetic and one ferromagnetic electrode, is theoretically investigated. By applying a time-varying bias voltage, the SMM's spin orientation can be manipulated with large bias voltage pulses. Moreover, the different magnetic configuration at high-resistance/low-resistance states can be ‘read out’ by utilizing relative low bias voltage. This device scheme can be implemented with current technologies (Khajetoorians et al 2013 Science 339 55) and has potential application in molecular spintronics and high-density nonvolatile memory devices.

  2. Case matching and the reduction of selection bias in quasi-experiments: The relative importance of pretest measures of outcome, of unreliable measurement, and of mode of data analysis.

    Science.gov (United States)

    Cook, Thomas D; Steiner, Peter M

    2010-03-01

    In this article, we note the many ontological, epistemological, and methodological similarities between how Campbell and Rubin conceptualize causation. We then explore 3 differences in their written emphases about individual case matching in observational studies. We contend that (a) Campbell places greater emphasis than Rubin on the special role of pretest measures of outcome among matching variables; (b) Campbell is more explicitly concerned with unreliability in the covariates; and (c) for analyzing the outcome, only Rubin emphasizes the advantages of using propensity score over regression methods. To explore how well these 3 factors reduce bias, we reanalyze and review within-study comparisons that contrast experimental and statistically adjusted nonexperimental causal estimates from studies with the same target population and treatment content. In this context, the choice of covariates counts most for reducing selection bias, and the pretest usually plays a special role relative to all the other covariates considered singly. Unreliability in the covariates also influences bias reduction but by less. Furthermore, propensity score and regression methods produce comparable degrees of bias reduction, though these within-study comparisons may not have met the theoretically specified conditions most likely to produce differences due to analytic method.

  3. Design of a new electrode array for cochlear implants

    International Nuclear Information System (INIS)

    Kha, H.; Chen, B.

    2010-01-01

    Full text: This study aims to design a new electrode array which can be precisely located beneath the basilar membrane within the cochlear scala tympani. This placement of the electrode array is beneficial for increasing the effectiveness of the electrical stimulation of the audi tory nerves and maximising the growth factors delivered into the cochlea for regenerating the progressively lost auditory neurons, thereby significantly improving performance of the cochlear implant systems. Methods The design process involved two steps. First, the biocom patible nitinol-based shape memory alloy, of which mechanical deformation can be controlled using electrical cUTents/fields act vated by body temperature, was selected. Second, five different designs of the electrode array with embedded nitinol actuators were studied (Table I). The finite element method was employed to predict final positions of these electrode arrays. Results The electrode array with three 6 mm actuators at 2-8, 8-J4 and 14-20 mm from the tip (Fig. I) was found to be located most closely to the basilar membrane, compared with those in the other four cases. Conclusions A new nitinol cochlear implant electrode array with three embedded nitinol actuators has been designed. This electrode array is expected to be located beneath the basilar membrane for maximising the delivery of growth factors. Future research will involve the manufacturing of a prototype of this electrode array for use in insertion experiments and neurotrophin release tests.

  4. Biased Monte Carlo optimization: the basic approach

    International Nuclear Information System (INIS)

    Campioni, Luca; Scardovelli, Ruben; Vestrucci, Paolo

    2005-01-01

    It is well-known that the Monte Carlo method is very successful in tackling several kinds of system simulations. It often happens that one has to deal with rare events, and the use of a variance reduction technique is almost mandatory, in order to have Monte Carlo efficient applications. The main issue associated with variance reduction techniques is related to the choice of the value of the biasing parameter. Actually, this task is typically left to the experience of the Monte Carlo user, who has to make many attempts before achieving an advantageous biasing. A valuable result is provided: a methodology and a practical rule addressed to establish an a priori guidance for the choice of the optimal value of the biasing parameter. This result, which has been obtained for a single component system, has the notable property of being valid for any multicomponent system. In particular, in this paper, the exponential and the uniform biases of exponentially distributed phenomena are investigated thoroughly

  5. Assessing Projection Bias in Consumers' Food Preferences.

    Directory of Open Access Journals (Sweden)

    Tiziana de-Magistris

    Full Text Available The aim of this study is to test whether projection bias exists in consumers' purchasing decisions for food products. To achieve our aim, we used a non-hypothetical experiment (i.e., experimental auction, where hungry and non-hungry participants were incentivized to reveal their willingness to pay (WTP. The results confirm the existence of projection bias when consumers made their decisions on food products. In particular, projection bias existed because currently hungry participants were willing to pay a higher price premium for cheeses than satiated ones, both in hungry and satiated future states. Moreover, participants overvalued the food product more when they were delivered in the future hungry condition than in the satiated one. Our study provides clear, quantitative and meaningful evidence of projection bias because our findings are based on economic valuation of food preferences. Indeed, the strength of this study is that findings are expressed in terms of willingness to pay which is an interpretable amount of money.

  6. Electron beam dynamics in an ultrafast transmission electron microscope with Wehnelt electrode.

    Science.gov (United States)

    Bücker, K; Picher, M; Crégut, O; LaGrange, T; Reed, B W; Park, S T; Masiel, D J; Banhart, F

    2016-12-01

    High temporal resolution transmission electron microscopy techniques have shown significant progress in recent years. Using photoelectron pulses induced by ultrashort laser pulses on the cathode, these methods can probe ultrafast materials processes and have revealed numerous dynamic phenomena at the nanoscale. Most recently, the technique has been implemented in standard thermionic electron microscopes that provide a flexible platform for studying material's dynamics over a wide range of spatial and temporal scales. In this study, the electron pulses in such an ultrafast transmission electron microscope are characterized in detail. The microscope is based on a thermionic gun with a Wehnelt electrode and is operated in a stroboscopic photoelectron mode. It is shown that the Wehnelt bias has a decisive influence on the temporal and energy spread of the picosecond electron pulses. Depending on the shape of the cathode and the cathode-Wehnelt distance, different emission patterns with different pulse parameters are obtained. The energy spread of the pulses is determined by space charge and Boersch effects, given by the number of electrons in a pulse. However, filtering effects due to the chromatic aberrations of the Wehnelt electrode allow the extraction of pulses with narrow energy spreads. The temporal spread is governed by electron trajectories of different length and in different electrostatic potentials. High temporal resolution is obtained by excluding shank emission from the cathode and aberration-induced halos in the emission pattern. By varying the cathode-Wehnelt gap, the Wehnelt bias, and the number of photoelectrons in a pulse, tradeoffs between energy and temporal resolution as well as beam intensity can be made as needed for experiments. Based on the characterization of the electron pulses, the optimal conditions for the operation of ultrafast TEMs with thermionic gun assembly are elaborated. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. On biases in precise point positioning with multi-constellation and multi-frequency GNSS data

    International Nuclear Information System (INIS)

    El-Mowafy, A; Deo, M; Rizos, C

    2016-01-01

    Various types of biases in Global Navigation Satellite System (GNSS) data preclude integer ambiguity fixing and degrade solution accuracy when not being corrected during precise point positioning (PPP). In this contribution, these biases are first reviewed, including satellite and receiver hardware biases, differential code biases, differential phase biases, initial fractional phase biases, inter-system receiver time biases, and system time scale offset. PPP models that take account of these biases are presented for two cases using ionosphere-free observations. The first case is when using primary signals that are used to generate precise orbits and clock corrections. The second case applies when using additional signals to the primary ones. In both cases, measurements from single and multiple constellations are addressed. It is suggested that the satellite-related code biases be handled as calibrated quantities that are obtained from multi-GNSS experiment products and the fractional phase cycle biases obtained from a network to allow for integer ambiguity fixing. Some receiver-related biases are removed using between-satellite single differencing, whereas other receiver biases such as inter-system biases are lumped with differential code and phase biases and need to be estimated. The testing results show that the treatment of biases significantly improves solution convergence in the float ambiguity PPP mode, and leads to ambiguity-fixed PPP within a few minutes with a small improvement in solution precision. (paper)

  8. Heuristic Biases in Mathematical Reasoning

    Science.gov (United States)

    Inglis, Matthew; Simpson, Adrian

    2005-01-01

    In this paper we briefly describe the dual process account of reasoning, and explain the role of heuristic biases in human thought. Concentrating on the so-called matching bias effect, we describe a piece of research that indicates a correlation between success at advanced level mathematics and an ability to override innate and misleading…

  9. Gender bias affects forests worldwide

    Science.gov (United States)

    Marlène Elias; Susan S Hummel; Bimbika S Basnett; Carol J.P. Colfer

    2017-01-01

    Gender biases persist in forestry research and practice. These biases result in reduced scientific rigor and inequitable, ineffective, and less efficient policies, programs, and interventions. Drawing from a two-volume collection of current and classic analyses on gender in forests, we outline five persistent and inter-related themes: gendered governance, tree tenure,...

  10. Anti-Bias Education: Reflections

    Science.gov (United States)

    Derman-Sparks, Louise

    2011-01-01

    It is 30 years since NAEYC published "Anti-Bias Curriculum Tools for Empowering Young Children" (Derman-Sparks & ABC Task Force, 1989). Since then, anti-bias education concepts have become part of the early childhood education (ECE) narrative in the United States and many other countries. It has brought a fresh way of thinking about…

  11. Correlation between photoelectrochemical behaviour and photoelectrocatalytic activity and scaling-up of P25-TiO2 electrodes

    International Nuclear Information System (INIS)

    Pablos, Cristina; Marugán, Javier; Grieken, Rafael van; Adán, Cristina; Riquelme, Ainhoa; Palma, Jesús

    2014-01-01

    The use of TiO 2 electrodes may solve the two main drawbacks of photocatalytic processes: i) the necessity of recovering the catalyst and ii) the low quantum yield in the use of the radiation. This work focuses on the correlation between the photoelectrochemical properties of TiO 2 electrodes and their activity for the photoelectrocatalytic oxidation of methanol. Particulate TiO 2 electrodes prepared by deposition of P25-TiO 2 nanoparticles on titanium (TiO 2 /Ti) or conductive glass support (TiO 2 /ITO) seem to be effective for charge carrier transference on TiO 2 surface favouring the formation of ·OH radicals and consequently, the oxidation of molecules. In contrast, thermal TiO 2 electrodes prepared by annealing of titanium (Ti) present better properties for charge carrier separation as a consequence of the application of a potential bias. Despite reducing charge carrier recombination by applying an electric potential bias, the activity of thermal electrodes remains lower than that of P25-particulate electrodes. TiO 2 structure of P25-particulate electrodes does not completely allow developing a potential gradient. However, their adequate TiO 2 layer characteristics for charge carrier transfer lead to a reduction in charge carrier recombination making up for the lack of charge carrier separation when applying an electric potential bias. TiO 2 /Ti showed the highest values of activity. Therefore, the combination of the suitable TiO 2 surface properties for charge carrier transfer with an adequate conductive support seems to increase the properties of the electrode for allowing charge carrier separation. The scaling-up calculations for a TiO 2 /ITO electrode do lead to good estimations of the activity and photocurrent of larger electrodes since this photoanode made from ITO as conductive support does not seem to be significantly affected by the applied potential bias

  12. The SDT Model of Belief Bias: Complexity, Time, and Cognitive Ability Mediate the Effects of Believability

    Science.gov (United States)

    Trippas, Dries; Handley, Simon J.; Verde, Michael F.

    2013-01-01

    When people evaluate conclusions, they are often influenced by prior beliefs. Prevalent theories claim that "belief bias" affects the quality of syllogistic reasoning. However, recent work by Dube, Rotello, and Heit (2010) has suggested that belief bias may be a simple response bias. In Experiment 1, receiver operating characteristic…

  13. Surprise, Memory, and Retrospective Judgment Making: Testing Cognitive Reconstruction Theories of the Hindsight Bias Effect

    Science.gov (United States)

    Ash, Ivan K.

    2009-01-01

    Hindsight bias has been shown to be a pervasive and potentially harmful decision-making bias. A review of 4 competing cognitive reconstruction theories of hindsight bias revealed conflicting predictions about the role and effect of expectation or surprise in retrospective judgment formation. Two experiments tested these predictions examining the…

  14. [Detection of surface EMG signal using active electrode].

    Science.gov (United States)

    He, Qinghua; Peng, Chenglin; Wu, Baoming; Wang, He

    2003-09-01

    Research of surface electromyogram(EMG) signal is important in rehabilitation medicine, sport medicine and clinical diagnosis, accurate detection of signal is the base of quantitative analysis of surface EMG signal. In this article were discussed how to reduce possible noise in the detection of surface EMG. Considerations on the design of electrode unit were presented. Instrumentation amplifier AD620 was employed to design a bipolar active electrode for use in surface EMG detection. The experiments showed that active electrode could be used to improve signal/noise ratio, reduce noise and detect surface EMG signal effectively.

  15. Dipole-induced exchange bias.

    Science.gov (United States)

    Torres, Felipe; Morales, Rafael; Schuller, Ivan K; Kiwi, Miguel

    2017-11-09

    The discovery of dipole-induced exchange bias (EB), switching from negative to positive sign, is reported in systems where the antiferromagnet and the ferromagnet are separated by a paramagnetic spacer (AFM-PM-FM). The magnitude and sign of the EB is determined by the cooling field strength and the PM thickness. The same cooling field yields negative EB for thin spacers, and positive EB for thicker ones. The EB decay profile as a function of the spacer thickness, and the change of sign, are attributed to long-ranged dipole coupling. Our model, which accounts quantitatively for the experimental results, ignores the short range interfacial exchange interactions of the usual EB theories. Instead, it retains solely the long range dipole field that allows for the coupling of the FM and AFM across the PM spacer. The experiments allow for novel switching capabilities of long range EB systems, while the theory allows description of the structures where the FM and AFM are not in atomic contact. The results provide a new approach to design novel interacting heterostructures.

  16. Large-scale galaxy bias

    Science.gov (United States)

    Desjacques, Vincent; Jeong, Donghui; Schmidt, Fabian

    2018-02-01

    This review presents a comprehensive overview of galaxy bias, that is, the statistical relation between the distribution of galaxies and matter. We focus on large scales where cosmic density fields are quasi-linear. On these scales, the clustering of galaxies can be described by a perturbative bias expansion, and the complicated physics of galaxy formation is absorbed by a finite set of coefficients of the expansion, called bias parameters. The review begins with a detailed derivation of this very important result, which forms the basis of the rigorous perturbative description of galaxy clustering, under the assumptions of General Relativity and Gaussian, adiabatic initial conditions. Key components of the bias expansion are all leading local gravitational observables, which include the matter density but also tidal fields and their time derivatives. We hence expand the definition of local bias to encompass all these contributions. This derivation is followed by a presentation of the peak-background split in its general form, which elucidates the physical meaning of the bias parameters, and a detailed description of the connection between bias parameters and galaxy statistics. We then review the excursion-set formalism and peak theory which provide predictions for the values of the bias parameters. In the remainder of the review, we consider the generalizations of galaxy bias required in the presence of various types of cosmological physics that go beyond pressureless matter with adiabatic, Gaussian initial conditions: primordial non-Gaussianity, massive neutrinos, baryon-CDM isocurvature perturbations, dark energy, and modified gravity. Finally, we discuss how the description of galaxy bias in the galaxies' rest frame is related to clustering statistics measured from the observed angular positions and redshifts in actual galaxy catalogs.

  17. Large-scale galaxy bias

    Science.gov (United States)

    Jeong, Donghui; Desjacques, Vincent; Schmidt, Fabian

    2018-01-01

    Here, we briefly introduce the key results of the recent review (arXiv:1611.09787), whose abstract is as following. This review presents a comprehensive overview of galaxy bias, that is, the statistical relation between the distribution of galaxies and matter. We focus on large scales where cosmic density fields are quasi-linear. On these scales, the clustering of galaxies can be described by a perturbative bias expansion, and the complicated physics of galaxy formation is absorbed by a finite set of coefficients of the expansion, called bias parameters. The review begins with a detailed derivation of this very important result, which forms the basis of the rigorous perturbative description of galaxy clustering, under the assumptions of General Relativity and Gaussian, adiabatic initial conditions. Key components of the bias expansion are all leading local gravitational observables, which include the matter density but also tidal fields and their time derivatives. We hence expand the definition of local bias to encompass all these contributions. This derivation is followed by a presentation of the peak-background split in its general form, which elucidates the physical meaning of the bias parameters, and a detailed description of the connection between bias parameters and galaxy (or halo) statistics. We then review the excursion set formalism and peak theory which provide predictions for the values of the bias parameters. In the remainder of the review, we consider the generalizations of galaxy bias required in the presence of various types of cosmological physics that go beyond pressureless matter with adiabatic, Gaussian initial conditions: primordial non-Gaussianity, massive neutrinos, baryon-CDM isocurvature perturbations, dark energy, and modified gravity. Finally, we discuss how the description of galaxy bias in the galaxies' rest frame is related to clustering statistics measured from the observed angular positions and redshifts in actual galaxy catalogs.

  18. Feasibility of Parylene Coating for Planar Electroporation Copper Electrodes

    Directory of Open Access Journals (Sweden)

    Vitalij NOVICKIJ

    2017-08-01

    Full Text Available This paper is focused on the feasibility study of parylene as a biocompatible coating for planar electroporation microelectrodes. The planar parallel and the circular interdigitated electrodes are applied in the analysis. The electrodes feature 100 μm width with a 300 μm gap between anode and cathode. The parylene coating thickness was varied in the 250 nm – 2 μm range. The resultant electric field distribution evaluation has been performed using the finite element method. The electrodes have been applied in electroporation experiments with Saprolegnia parasitica. For reference the additional experiments using conventional electroporation cuvette (1 mm gap have been performed. It has been determined that the parylene coating with hydrophobic properties has limited applicability for the passivation of the planar electroporation electrodes.DOI: http://dx.doi.org/10.5755/j01.ms.23.2.14953

  19. Transparent Electrodes for Efficient Optoelectronics

    KAUST Repository

    Morales-Masis, Monica

    2017-03-30

    With the development of new generations of optoelectronic devices that combine high performance and novel functionalities (e.g., flexibility/bendability, adaptability, semi or full transparency), several classes of transparent electrodes have been developed in recent years. These range from optimized transparent conductive oxides (TCOs), which are historically the most commonly used transparent electrodes, to new electrodes made from nano- and 2D materials (e.g., metal nanowire networks and graphene), and to hybrid electrodes that integrate TCOs or dielectrics with nanowires, metal grids, or ultrathin metal films. Here, the most relevant transparent electrodes developed to date are introduced, their fundamental properties are described, and their materials are classified according to specific application requirements in high efficiency solar cells and flexible organic light-emitting diodes (OLEDs). This information serves as a guideline for selecting and developing appropriate transparent electrodes according to intended application requirements and functionality.

  20. Transparent Electrodes for Efficient Optoelectronics

    KAUST Repository

    Morales-Masis, Monica; De Wolf, Stefaan; Woods-Robinson, Rachel; Ager, Joel W.; Ballif, Christophe

    2017-01-01

    With the development of new generations of optoelectronic devices that combine high performance and novel functionalities (e.g., flexibility/bendability, adaptability, semi or full transparency), several classes of transparent electrodes have been developed in recent years. These range from optimized transparent conductive oxides (TCOs), which are historically the most commonly used transparent electrodes, to new electrodes made from nano- and 2D materials (e.g., metal nanowire networks and graphene), and to hybrid electrodes that integrate TCOs or dielectrics with nanowires, metal grids, or ultrathin metal films. Here, the most relevant transparent electrodes developed to date are introduced, their fundamental properties are described, and their materials are classified according to specific application requirements in high efficiency solar cells and flexible organic light-emitting diodes (OLEDs). This information serves as a guideline for selecting and developing appropriate transparent electrodes according to intended application requirements and functionality.

  1. Extraction of network topology from multi-electrode recordings: Is there a small-world effect?

    Directory of Open Access Journals (Sweden)

    Felipe eGerhard

    2011-02-01

    Full Text Available The simultaneous recording of the activity of many neurons poses challenges for multivariate data analysis. Here, we propose a general scheme of reconstruction of the functional network from spike train recordings. Effective, causal interactions are estimated by fitting Generalized Linear Models (GLMs on the neural responses, incorporating effects of the neurons' self-history, of input from other neurons in the recorded network and of modulation by an external stimulus. The coupling terms arising from synaptic input can be transformed by thresholding into a binary connectivity matrix which is directed. Each link between two neurons represents a causal influence from one neuron to the other, given the observation of all other neurons from the population. The resulting graph is analyzed with respect to small-world and scale-free properties using quantitative measures for directed networks. Such graph-theoretic analyses have been performed on many complex dynamic networks, including the connectivity structure between different brain areas. Only few studies have attempted to look at the structure of cortical neural networks on the level of individual neurons. Here, using multi-electrode recordings from the visual system of the awake monkey, we find that cortical networks lack scale-free behavior, but show a small, but significant small-world structure. Assuming a simple distance-dependent probabilistic wiring between neurons, we find that this connectivity structure can account for all of the networks' observed small-world-ness. Moreover, for multi-electrode recordings the sampling of neurons is not uniform across the population. We show that the small-world-ness obtained by such a localized sub-sampling overestimates the strength of the true small-world-structure of the network. This bias is likely to be present in all previous experiments based on multi-electrode recordings.

  2. Electrode for disintegrating metallic material

    International Nuclear Information System (INIS)

    Persang, J.C.

    1985-01-01

    A graphite electrode is provided for disintegrating and removing metallic material from a workpiece, e.g., such as portions of a nuclear reactor to be repaired while in an underwater and/or radioactive environment. The electrode is provided with a plurality of openings extending outwardly, and a manifold for supplying a mixture of water and compressed gas to be discharged through the openings for sweeping away the disintegrated metallic material during use of the electrode

  3. In-situ Raman spectroscopy as a characterization tool for carbon electrodes

    Energy Technology Data Exchange (ETDEWEB)

    Panitz, J -C; Joho, F B; Novak, P [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    1999-08-01

    Lithium intercalation and de-intercalation into/from graphite electrodes in a nonaqueous electrolyte has been studied using in-situ Raman spectroscopy. Our experiments give information on the electrode-electrolyte interface with improved spatial resolution. The spectra taken from the electrode surface change with electrode potential. In this way, information on the nature of the chemical species present during charging and discharging half cycles is gained. For the first time, mapping techniques were applied to investigate if lithium intercalation proceeds homogeneously on the carbon electrode. (author) 3 figs., 1 tab., 4 refs.

  4. Comparison of unusual carbon-based working electrodes for electrochemiluminescence sensors.

    Science.gov (United States)

    Noman, Muhammad; Sanginario, Alessandro; Jagadale, Pravin; Demarchi, Danilo; Tagliaferro, Alberto

    2017-06-01

    In this work, unconventional carbon-based materials were investigated for use in electrochemiluminescence (ECL) working electrodes. Precursors such as bamboo, pistachio shells, kevlar ® fibers and camphor were differently treated and used as working electrodes in ECL experiments. After a proper process they were assembled as electrodes and tested in an electrochemical cell. Comparison among them and with a commercial glassy carbon electrode (GCE) shows a very good response for all of them thus demonstrating their potential use as disposable low-cost electrodes for early detection electrochemical analysis. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Cognitive bias in action: evidence for a reciprocal relation between confirmation bias and fear in children.

    Science.gov (United States)

    Remmerswaal, Danielle; Huijding, Jorg; Bouwmeester, Samantha; Brouwer, Marlies; Muris, Peter

    2014-03-01

    Some cognitive models propose that information processing biases and fear are reciprocally related. This idea has never been formally tested. Therefore, this study investigated the existence of a vicious circle by which confirmation bias and fear exacerbate each other. One-hundred-and-seventy-one school children (8-13 years) were first provided with threatening, ambiguous, or positive information about an unknown animal. Then they completed a computerized information search task during which they could collect additional (negative, positive, or neutral) information about the novel animal. Because fear levels were repeatedly assessed during the task, it was possible to examine the reciprocal relationship between confirmation bias and fear. A reciprocal relation of mutual reinforcement was found between confirmation bias and fear over the course of the experiment: increases in fear predicted subsequent increases in the search for negative information, and increases in the search for negative information further enhanced fear on a later point-in-time. In addition, the initial information given about the animals successfully induced diverging fear levels in the children, and determined their first inclination to search for additional information. As this study employed a community sample of primary school children, future research should test whether these results can be generalized to clinically anxious youth. These findings provide first support for the notion that fearful individuals may become trapped in a vicious circle in which fear and a fear-related confirmation bias mutually strengthen each other, thereby maintaining the anxiety pathology. Copyright © 2013 Elsevier Ltd. All rights reserved.

  6. Sheath and bulk expansion induced by RF bias in atmospheric pressure microwave plasma

    Science.gov (United States)

    Lee, Jimo; Nam, Woojin; Lee, Jae Koo; Yun, Gunsu

    2017-10-01

    A large axial volume expansion of microwave-driven plasma at atmospheric pressure is achieved by applying a low power radio frequency (RF) bias at an axial location well isolated from the original plasma bulk. The evolution of the plasma plume visualized by high speed ICCD imaging suggest that the free electrons drifting toward the bias electrode cause the prodigious expansion of the sheath, creating a stable plasma stream channel between the microwave and the RF electrodes. For argon plasma in ambient air, enhanced emissions of OH and N2 spectral lines are measured in the extended plume region, supporting the acceleration of electrons and subsequent generation of radical species. The coupling of RF bias with microwave provides an efficient way of enlarging the plasma volume and enhancing the production of radicals. Work supported by the National Research Foundation of Korea under BK21+ program and Grant No. 2015R1D1A1A01061556 (Ministry of Education).

  7. AC bias operation of the perpendicular biased ferrite tuned cavity for the TRIUMF KAON Factory booster synchrotron

    International Nuclear Information System (INIS)

    Poirier, R.L.; Enegren, T.A.; Enchevich, I.B.

    1991-05-01

    The RF cavity for the booster synchrotron requires a frequency swing from 46 MHz at a repetition rate of 50 Hz and a maximum accelerating gap voltage of 65 kV. A DC biased prototype cavity built at LANL using perpendicular-biased yttrium-garnet ferrites, rather than the more conventional parallel-biased NiZn ferrites, has now undergone major reconstruction at TRIUMF for AC bias operation. RF signal level measurements have shown that the frequency swing at a repetition rate of 50 Hz can be accomplished and still handle the eddy current losses in the cavity structures with minimal effect on the magnetizing field. The prototype cavity is now undergoing high power RF tests with full power AC bias operation. The results of these tests and operational experience is reported. (Author) ref., 6 figs

  8. Ion-selective electrode reviews

    CERN Document Server

    Thomas, J D R

    1982-01-01

    Ion-Selective Electrode Reviews, Volume 3, provides a review of articles on ion-selective electrodes (ISEs). The volume begins with an article on methods based on titration procedures for surfactant analysis, which have been developed for discrete batch operation and for continuous AutoAnalyser use. Separate chapters deal with detection limits of ion-selective electrodes; the possibility of using inorganic ion-exchange materials as ion-sensors; and the effect of solvent on potentials of cells with ion-selective electrodes. Also included is a chapter on advances in calibration procedures, the d

  9. Field testing of sulphide electrodes

    International Nuclear Information System (INIS)

    Singh, P.R.; Gaonkar, K.B.; Gadiyar, H.S.

    1993-01-01

    Sulphide ion selective electrodes have been developed at BARC, for determination of Ag + and S - ions directly and Cl - and CN - ions indirectly. The electrodes were tested for their use in sulphide environments in the EAD (Effluent After Dilution) stream at the Heavy Water Plant, Kota. The electrodes are suitable in the concentration range of 16000 ppm to 0.002 ppm, with a slope of 29-31 mV per decade change in the sulphide ion concentration. The response time is less than 10 seconds. These electrodes are reliable for continuous on-line use for a long period. (author). 7 refs., 11 figs., 1 tab

  10. Coated carbon nanotube array electrodes

    Science.gov (United States)

    Ren, Zhifeng [Newton, MA; Wen, Jian [Newton, MA; Chen, Jinghua [Chestnut Hill, MA; Huang, Zhongping [Belmont, MA; Wang, Dezhi [Wellesley, MA

    2008-10-28

    The present invention provides conductive carbon nanotube (CNT) electrode materials comprising aligned CNT substrates coated with an electrically conducting polymer, and the fabrication of electrodes for use in high performance electrical energy storage devices. In particular, the present invention provides conductive CNTs electrode material whose electrical properties render them especially suitable for use in high efficiency rechargeable batteries. The present invention also provides methods for obtaining surface modified conductive CNT electrode materials comprising an array of individual linear, aligned CNTs having a uniform surface coating of an electrically conductive polymer such as polypyrrole, and their use in electrical energy storage devices.

  11. Lithium alloy negative electrodes

    Science.gov (United States)

    Huggins, Robert A.

    The 1996 announcement by Fuji Photo Film of the development of lithium batteries containing convertible metal oxides has caused a great deal of renewed interest in lithium alloys as alternative materials for use in the negative electrode of rechargeable lithium cells. The earlier work on lithium alloys, both at elevated and ambient temperatures is briefly reviewed. Basic principles relating thermodynamics, phase diagrams and electrochemical properties under near-equilibrium conditions are discussed, with the Li-Sn system as an example. Second-phase nucleation, and its hindrance under dynamic conditions plays an important role in determining deviations from equilibrium behavior. Two general types of composite microstructure electrodes, those with a mixed-conducting matrix, and those with a solid electrolyte matrix, are discussed. The Li-Sn-Si system at elevated temperatures, and the Li-Sn-Cd at ambient temperatures are shown to be examples of mixed-conducting matrix microstructures. The convertible oxides are an example of the solid electrolyte matrix type. Although the reversible capacity can be very large in this case, the first cycle irreversible capacity required to convert the oxides to alloys may be a significant handicap.

  12. Cognitive Bias in Systems Verification

    Science.gov (United States)

    Larson, Steve

    2012-01-01

    Working definition of cognitive bias: Patterns by which information is sought and interpreted that can lead to systematic errors in decisions. Cognitive bias is used in diverse fields: Economics, Politics, Intelligence, Marketing, to name a few. Attempts to ground cognitive science in physical characteristics of the cognitive apparatus exceed our knowledge. Studies based on correlations; strict cause and effect is difficult to pinpoint. Effects cited in the paper and discussed here have been replicated many times over, and appear sound. Many biases have been described, but it is still unclear whether they are all distinct. There may only be a handful of fundamental biases, which manifest in various ways. Bias can effect system verification in many ways . Overconfidence -> Questionable decisions to deploy. Availability -> Inability to conceive critical tests. Representativeness -> Overinterpretation of results. Positive Test Strategies -> Confirmation bias. Debiasing at individual level very difficult. The potential effect of bias on the verification process can be managed, but not eliminated. Worth considering at key points in the process.

  13. Administrative bias in South Africa

    Directory of Open Access Journals (Sweden)

    E S Nwauche

    2005-01-01

    Full Text Available This article reviews the interpretation of section 6(2(aii of the Promotion of Administrative Justice Act which makes an administrator “biased or reasonably suspected of bias” a ground of judicial review. In this regard, the paper reviews the determination of administrative bias in South Africa especially highlighting the concept of institutional bias. The paper notes that inspite of the formulation of the bias ground of review the test for administrative bias is the reasonable apprehension test laid down in the case of President of South Africa v South African Rugby Football Union(2 which on close examination is not the same thing. Accordingly the paper urges an alternative interpretation that is based on the reasonable suspicion test enunciated in BTR Industries South Africa (Pty Ltd v Metal and Allied Workers Union and R v Roberts. Within this context, the paper constructs a model for interpreting the bias ground of review that combines the reasonable suspicion test as interpreted in BTR Industries and R v Roberts, the possibility of the waiver of administrative bias, the curative mechanism of administrative appeal as well as some level of judicial review exemplified by the jurisprudence of article 6(1 of the European Convention of Human Rights, especially in the light of the contemplation of the South African Magistrate Court as a jurisdictional route of judicial review.

  14. Moisture Forecast Bias Correction in GEOS DAS

    Science.gov (United States)

    Dee, D.

    1999-01-01

    Data assimilation methods rely on numerous assumptions about the errors involved in measuring and forecasting atmospheric fields. One of the more disturbing of these is that short-term model forecasts are assumed to be unbiased. In case of atmospheric moisture, for example, observational evidence shows that the systematic component of errors in forecasts and analyses is often of the same order of magnitude as the random component. we have implemented a sequential algorithm for estimating forecast moisture bias from rawinsonde data in the Goddard Earth Observing System Data Assimilation System (GEOS DAS). The algorithm is designed to remove the systematic component of analysis errors and can be easily incorporated in an existing statistical data assimilation system. We will present results of initial experiments that show a significant reduction of bias in the GEOS DAS moisture analyses.

  15. Calibration biases in logical reasoning tasks

    Directory of Open Access Journals (Sweden)

    Guillermo Macbeth

    2013-08-01

    Full Text Available The aim of this contribution is to present an experimental study about calibration in deductive reasoning tasks. Calibration is defi ned as the empirical convergence or divergence between the objective and the subjective success. The underconfi dence bias is understood as the dominance of the former over the latter. The hypothesis of this study states that the form of the propositions presented in the experiment is critical for calibration phenomena. Affi rmative and negative propositions are distinguished in their cognitive processing. Results suggests that monotonous compound propositions are prone to underconfi dence. An heuristic approach to this phenomenon is proposed. The activation of a monotony heuristic would produce an illusion of simplicity that generates the calibration bias. These evidence is analysed in the context of the metacognitive modeling of calibration phenomena.

  16. Bias During the Evaluation of Animal Studies?

    Science.gov (United States)

    Knight, Andrew

    2012-02-23

    My recent book entitled The Costs and Benefits of Animal Experiments seeks to answer a key question within animal ethics, namely: is animal experimentation ethically justifiable? Or, more precisely, is it justifiable within the utilitarian cost:benefit framework that fundamentally underpins most regulations governing animal experimentation? To answer this question I reviewed more than 500 scientific publications describing animal studies, animal welfare impacts, and alternative research, toxicity testing and educational methodologies. To minimise bias I focused primarily on large-scale systematic reviews that had examined the human clinical and toxicological utility of animal studies. Despite this, Dr. Susanne Prankel recently reviewed my book in this journal, essentially accusing me of bias. However, she failed to provide any substantive evidence to refute my conclusions, let alone evidence of similar weight to that on which they are based. Those conclusions are, in fact, firmly based on utilitarian ethical reasoning, informed by scientific evidence of considerable strength, and I believe they are robust.

  17. Gas sensor with multiple internal reference electrodes and sensing electrodes

    DEFF Research Database (Denmark)

    2016-01-01

    The invention relates to a potentiometric gas sensor, or potentiometric gas detection element, with multiple internal reference electrodes and multiple sensing electrodes for determining the concentrations of gas components in a gaseous mixture. The sensor for gas detection comprises: a solid...

  18. Critical Thinking and Cognitive Bias

    Directory of Open Access Journals (Sweden)

    Jeffrey Maynes

    2015-05-01

    Full Text Available Teaching critical thinking skill is a central pedagogical aim in many courses. These skills, it is hoped, will be both portable (applicable in a wide range of contexts and durable (not forgotten quickly. Yet, both of these virtues are challenged by pervasive and potent cognitive biases, such as motivated reasoning, false consensus bias and hindsight bias. In this paper, I argue that a focus on the development of metacognitive skill shows promise as a means to inculcate debiasing habits in students. Such habits will help students become more critical reasoners. I close with suggestions for implementing this strategy.

  19. Role of the antiferromagnetic bulk spins in exchange bias

    Energy Technology Data Exchange (ETDEWEB)

    Schuller, Ivan K. [Center for Advanced Nanoscience and Physics Department, University of California San Diego, La Jolla, CA 92093 (United States); Morales, Rafael, E-mail: rafael.morales@ehu.es [Department of Chemical-Physics & BCMaterials, University of the Basque Country UPV/EHU (Spain); IKERBASQUE, Basque Foundation for Science, 48011 Bilbao (Spain); Batlle, Xavier [Departament Física Fonamental and Institut de Nanociència i Nanotecnologia, Universitat de Barcelona, c/ Martí i Franqués s/n, 08028 Barcelona, Catalonia (Spain); Nowak, Ulrich [Department of Physics, University of Konstanz, 78464 Konstanz (Germany); Güntherodt, Gernot [Physics Institute (IIA), RWTH Aachen University, Campus RWTH-Melaten, 52074 Aachen (Germany)

    2016-10-15

    This “Critical Focused Issue” presents a brief review of experiments and models which describe the origin of exchange bias in epitaxial or textured ferromagnetic/antiferromagnetic bilayers. Evidence is presented which clearly indicates that inner, uncompensated, pinned moments in the bulk of the antiferromagnet (AFM) play a very important role in setting the magnitude of the exchange bias. A critical evaluation of the extensive literature in the field indicates that it is useful to think of this bulk, pinned uncompensated moments as a new type of a ferromagnet which has a low total moment, an ordering temperature given by the AFM Néel temperature, with parallel aligned moments randomly distributed on the regular AFM lattice. - Highlights: • We address the role of bulk antiferromagnetic spins in the exchange bias phenomenon. • Significant experiments on how bulk AFM spins determine exchange bias are highlighted. • We explain the model that accounts for experimental results.

  20. Role of the antiferromagnetic bulk spins in exchange bias

    International Nuclear Information System (INIS)

    Schuller, Ivan K.; Morales, Rafael; Batlle, Xavier; Nowak, Ulrich; Güntherodt, Gernot

    2016-01-01

    This “Critical Focused Issue” presents a brief review of experiments and models which describe the origin of exchange bias in epitaxial or textured ferromagnetic/antiferromagnetic bilayers. Evidence is presented which clearly indicates that inner, uncompensated, pinned moments in the bulk of the antiferromagnet (AFM) play a very important role in setting the magnitude of the exchange bias. A critical evaluation of the extensive literature in the field indicates that it is useful to think of this bulk, pinned uncompensated moments as a new type of a ferromagnet which has a low total moment, an ordering temperature given by the AFM Néel temperature, with parallel aligned moments randomly distributed on the regular AFM lattice. - Highlights: • We address the role of bulk antiferromagnetic spins in the exchange bias phenomenon. • Significant experiments on how bulk AFM spins determine exchange bias are highlighted. • We explain the model that accounts for experimental results.

  1. Bias and Causation Models and Judgment for Valid Comparisons

    CERN Document Server

    Weisberg, Herbert I

    2010-01-01

    A one-of-a-kind resource on identifying and dealing with bias in statistical research on causal effects. Do cell phones cause cancer? Can a new curriculum increase student achievement? Determining what the real causes of such problems are, and how powerful their effects may be, are central issues in research across various fields of study. Some researchers are highly skeptical of drawing causal conclusions except in tightly controlled randomized experiments, while others discount the threats posed by different sources of bias, even in less rigorous observational studies. Bias and Causation pre

  2. Estimating Production Potentials: Expert Bias in Applied Decision Making

    International Nuclear Information System (INIS)

    Matthews, L.J.; Burggraf, L.K.; Reece, W.J.

    1998-01-01

    A study was conducted to evaluate how workers predict manufacturing production potentials given positively and negatively framed information. Findings indicate the existence of a bias toward positive information and suggest that this bias may be reduced with experience but is never the less maintained. Experts err in the same way non experts do in differentially processing negative and positive information. Additionally, both experts and non experts tend to overestimate production potentials in a positive direction. The authors propose that these biases should be addressed with further research including cross domain analyses and consideration in training, workplace design, and human performance modeling

  3. Molybdenum coated SU-8 microneedle electrodes for transcutaneous electrical nerve stimulation.

    Science.gov (United States)

    Soltanzadeh, Ramin; Afsharipour, Elnaz; Shafai, Cyrus; Anssari, Neda; Mansouri, Behzad; Moussavi, Zahra

    2017-11-21

    Electrophysiological devices are connected to the body through electrodes. In some applications, such as nerve stimulation, it is needed to minimally pierce the skin and reach the underneath layers to bypass the impedance of the first layer called stratum corneum. In this study, we have designed and fabricated surface microneedle electrodes for applications such as electrical peripheral nerve stimulation. We used molybdenum for microneedle fabrication, which is a biocompatible metal; it was used for the conductive layer of the needle array. To evaluate the performance of the fabricated electrodes, they were compared with the conventional surface electrodes in nerve conduction velocity experiment. The recorded signals showed a much lower contact resistance and higher bandwidth in low frequencies for the fabricated microneedle electrodes compared to those of the conventional electrodes. These results indicate the electrode-tissue interface capacitance and charge transfer resistance have been increased in our designed electrodes, while the contact resistance decreased. These changes will lead to less harmful Faradaic current passing through the tissue during stimulation in different frequencies. We also compared the designed microneedle electrodes with conventional ones by a 3-dimensional finite element simulation. The results demonstrated that the current density in the deep layers of the skin and the directivity toward a target nerve for microneedle electrodes were much more than those for the conventional ones. Therefore, the designed electrodes are much more efficient than the conventional electrodes for superficial transcutaneous nerve stimulation purposes.

  4. Catoptric electrodes: transparent metal electrodes using shaped surfaces.

    Science.gov (United States)

    Kik, Pieter G

    2014-09-01

    An optical electrode design is presented that theoretically allows 100% optical transmission through an interdigitated metallic electrode at 50% metal areal coverage. This is achieved by redirection of light incident on embedded metal electrode lines to an angle beyond that required for total internal reflection. Full-field electromagnetic simulations using realistic material parameters demonstrate 84% frequency-averaged transmission for unpolarized illumination across the entire visible spectral range using a silver interdigitated electrode at 50% areal coverage. The redirection is achieved through specular reflection, making it nonresonant and arbitrarily broadband, provided the electrode width exceeds the optical wavelength. These findings could significantly improve the performance of photovoltaic devices and optical detectors that require high-conductivity top contacts.

  5. TiN coated aluminum electrodes for DC high voltage electron guns

    International Nuclear Information System (INIS)

    Mamun, Md Abdullah A.; Elmustafa, Abdelmageed A.; Taus, Rhys; Forman, Eric; Poelker, Matthew

    2015-01-01

    Preparing electrodes made of metals like stainless steel, for use inside DC high voltage electron guns, is a labor-intensive and time-consuming process. In this paper, the authors report the exceptional high voltage performance of aluminum electrodes coated with hard titanium nitride (TiN). The aluminum electrodes were comparatively easy to manufacture and required only hours of mechanical polishing using silicon carbide paper, prior to coating with TiN by a commercial vendor. The high voltage performance of three TiN-coated aluminum electrodes, before and after gas conditioning with helium, was compared to that of bare aluminum electrodes, and electrodes manufactured from titanium alloy (Ti-6Al-4V). Following gas conditioning, each TiN-coated aluminum electrode reached −225 kV bias voltage while generating less than 100 pA of field emission (<10 pA) using a 40 mm cathode/anode gap, corresponding to field strength of 13.7 MV/m. Smaller gaps were studied to evaluate electrode performance at higher field strength with the best performing TiN-coated aluminum electrode reaching ∼22.5 MV/m with field emission less than 100 pA. These results were comparable to those obtained from our best-performing electrodes manufactured from stainless steel, titanium alloy and niobium, as reported in references cited below. The TiN coating provided a very smooth surface and with mechanical properties of the coating (hardness and modulus) superior to those of stainless steel, titanium-alloy, and niobium electrodes. These features likely contributed to the improved high voltage performance of the TiN-coated aluminum electrodes

  6. How we categorize objects is related to how we remember them: The shape bias as a memory bias.

    Science.gov (United States)

    Vlach, Haley A

    2016-12-01

    The "shape bias" describes the phenomenon that, after a certain point in development, children and adults generalize object categories based on shape to a greater degree than other perceptual features. The focus of research on the shape bias has been to examine the types of information that learners attend to in one moment in time. The current work takes a different approach by examining whether learners' categorical biases are related to their retention of information across time. In three experiments, children's (N=72) and adults' (N=240) memory performance for features of objects was examined in relation to their categorical biases. The results of these experiments demonstrated that the number of shape matches chosen during the shape bias task significantly predicted shape memory. Moreover, children and adults with a shape bias were more likely to remember the shape of objects than the color and size of objects. Taken together, this work suggests that the development of a shape bias may engender better memory for shape information. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. EDM Electrode for Internal Grooves

    Science.gov (United States)

    Ramani, V.; Werner, A.

    1985-01-01

    Electroerosive process inexpensive alternative to broaching. Hollow brass electrodes, soldered at one end to stainless-steel holding ring, held in grooves in mandrel. These electrodes used to machine grooves electrically in stainless-steel tube three-eights inch (9.5 millimeters) in diameter. Tool used on tubes already in place in equipment.

  8. Making EDM Electrodes By Stereolithography

    Science.gov (United States)

    Barlas, Philip A.

    1988-01-01

    Stereolithography is computer-aided manufacturing technique. Used to make models and molds of electrodes for electrical-discharge machining (EDM). Eliminates intermediate steps in fabrication of plastic model of object used in making EDM electrode to manufacture object or mold for object.

  9. Surface-modified electrodes (SME)

    NARCIS (Netherlands)

    Schreurs, J.P.G.M.; Barendrecht, E.

    1984-01-01

    This review deals with the literature (covered up to August 1983), the characterization and the applications of Surface-Modified Electrodes (SME). As a special class of SME's, the Enzyme-Modified Electrode (EME) is introduced. Three types of modification procedures are distinguished; i.e. covalent

  10. Storage-battery electrodes. [preparation

    Energy Technology Data Exchange (ETDEWEB)

    1961-12-29

    Two incompatible thermoplastic resins are mixed with a powdered electrochemical active substance. The substance may be, for example, an oxide of cadmium, iron, lead, or zinc or nickel hydroxide. After the mixture is shaped into elements which are inserted into conducting sheaths for an electrode, the one resin is washed out to form a porous electrode. (RWR)

  11. Electrochemical photovoltaic cells and electrodes

    Science.gov (United States)

    Skotheim, Terje A.

    1984-01-01

    Improved electrochemical photovoltaic cells and electrodes for use therein, particularly electrodes employing amorphous silicon or polyacetylene coating are produced by a process which includes filling pinholes or porous openings in the coatings by electrochemical oxidation of selected monomers to deposit insulating polymer in the openings.

  12. Improved photovoltaic cells and electrodes

    Science.gov (United States)

    Skotheim, T.A.

    1983-06-29

    Improved photovoltaic cells and electrodes for use therein, particularly electrodes employing amorphous silicon or polyacetylene coating are produced by a process which includes filling pinholes or porous openings in the coatings by electrochemical oxidation of selected monomers to deposit insulating polymer in the openings.

  13. A MORET tool to assist code bias estimation

    International Nuclear Information System (INIS)

    Fernex, F.; Richet, Y.; Letang, E.

    2003-01-01

    This new Graphical User Interface (GUI) developed in JAVA is one of the post-processing tools for MORET4 code. It aims to help users to estimate the importance of the k eff bias due to the code in order to better define the upper safety limit. Moreover, it allows visualizing the distance between an actual configuration case and evaluated critical experiments. This tool depends on a validated experiments database, on sets of physical parameters and on various statistical tools allowing interpolating the calculation bias of the database or displaying the projections of experiments on a reduced base of parameters. The development of this tool is still in progress. (author)

  14. Adsorption at electrodes

    International Nuclear Information System (INIS)

    Hubbard, A.T.; Ping Gao

    1991-01-01

    Surface electrochemical studies are described and summarized in which atomic, ionic or molecular layers were allowed to form from aqueous solutions at well-defined Pt(111) surfaces. The resulting adsorbed layers were chemisorbed in most cases and stable in vacuum, permitting identification and quantitation by Auger spectroscopy, EELS, LEED and electrochemistry. Adsorbed atomic, ionic, or molecular layers formed at metal-solution interfaces frequently display long-range order. Molecular properties of the adsorbed layers correlate with their electrochemical properties. The molecular orientation of organic adsorbates was deduced from packing density measurements, supplemented with vibrational spectra. Interfacial variables such as electrode potential have a strong influence on interfacial structure along with the nature and mode of surface attachment of adsorbates. The angular distribution of Auger electron emission from metal single crystals and atomic adsorbed layers has proved to be useful for direct imaging of surface crystal and interfacial structure. (author). 14 refs, 11 figs

  15. Gel electrolytes and electrodes

    Science.gov (United States)

    Fleischmann, Sven; Bunte, Christine; Mikhaylik, Yuriy V.; Viner, Veronika G.

    2017-09-05

    Gel electrolytes, especially gel electrolytes for electrochemical cells, are generally described. In some embodiments, the gel electrolyte layers comprise components a) to c). Component a) may be at least one layer of at least one polymer comprising polymerized units of: a1) at least one monomer containing an ethylenically unsaturated unit and an amido group and a2) at least one crosslinker. Component b) may be at least one conducting salt and component c) may be at least one solvent. Electrodes may comprise the components a), d) and e), wherein component a) may be at least one layer of at least one polymer as described herein. Component d) may be at least one electroactive layer and component e) may be at least one ceramic layer. Furthermore, electrochemical cells comprising component a) which may be at least one layer of at least one polymer as described herein, are also provided.

  16. Electrode for a lithium cell

    Science.gov (United States)

    Thackeray, Michael M [Naperville, IL; Vaughey, John T [Elmhurst, IL; Dees, Dennis W [Downers Grove, IL

    2008-10-14

    This invention relates to a positive electrode for an electrochemical cell or battery, and to an electrochemical cell or battery; the invention relates more specifically to a positive electrode for a non-aqueous lithium cell or battery when the electrode is used therein. The positive electrode includes a composite metal oxide containing AgV.sub.3O.sub.8 as one component and one or more other components consisting of LiV.sub.3O.sub.8, Ag.sub.2V.sub.4O.sub.11, MnO.sub.2, CF.sub.x, AgF or Ag.sub.2O to increase the energy density of the cell, optionally in the presence of silver powder and/or silver foil to assist in current collection at the electrode and to improve the power capability of the cell or battery.

  17. Preferences, country bias, and international trade

    NARCIS (Netherlands)

    S. Roy (Santanu); J.M.A. Viaene (Jean-Marie)

    1998-01-01

    textabstractAnalyzes international trade where consumer preferences exhibit country bias. Why country biases arise; How trade can occur in the presence of country bias; Implication for the pattern of trade and specialization.

  18. Examining Event-Related Potential (ERP) correlates of decision bias in recognition memory judgments.

    Science.gov (United States)

    Hill, Holger; Windmann, Sabine

    2014-01-01

    Memory judgments can be based on accurate memory information or on decision bias (the tendency to report that an event is part of episodic memory when one is in fact unsure). Event related potentials (ERP) correlates are important research tools for elucidating the dynamics underlying memory judgments but so far have been established only for investigations of accurate old/new discrimination. To identify the ERP correlates of bias, and observe how these interact with ERP correlates of memory, we conducted three experiments that manipulated decision bias within participants via instructions during recognition memory tests while their ERPs were recorded. In Experiment 1, the bias manipulation was performed between blocks of trials (automatized bias) and compared to trial-by-trial shifts of bias in accord with an external cue (flexibly controlled bias). In Experiment 2, the bias manipulation was performed at two different levels of accurate old/new discrimination as the memory strength of old (studied) items was varied. In Experiment 3, the bias manipulation was added to another, bottom-up driven manipulation of bias induced via familiarity. In the first two Experiments, and in the low familiarity condition of Experiment 3, we found evidence of an early frontocentral ERP component at 320 ms poststimulus (the FN320) that was sensitive to the manipulation of bias via instruction, with more negative amplitudes indexing more liberal bias. By contrast, later during the trial (500-700 ms poststimulus), bias effects interacted with old/new effects across all three experiments. Results suggest that the decision criterion is typically activated early during recognition memory trials, and is integrated with retrieved memory signals and task-specific processing demands later during the trial. More generally, the findings demonstrate how ERPs can help to specify the dynamics of recognition memory processes under top-down and bottom-up controlled retrieval conditions.

  19. Examining Event-Related Potential (ERP) Correlates of Decision Bias in Recognition Memory Judgments

    Science.gov (United States)

    Hill, Holger; Windmann, Sabine

    2014-01-01

    Memory judgments can be based on accurate memory information or on decision bias (the tendency to report that an event is part of episodic memory when one is in fact unsure). Event related potentials (ERP) correlates are important research tools for elucidating the dynamics underlying memory judgments but so far have been established only for investigations of accurate old/new discrimination. To identify the ERP correlates of bias, and observe how these interact with ERP correlates of memory, we conducted three experiments that manipulated decision bias within participants via instructions during recognition memory tests while their ERPs were recorded. In Experiment 1, the bias manipulation was performed between blocks of trials (automatized bias) and compared to trial-by-trial shifts of bias in accord with an external cue (flexibly controlled bias). In Experiment 2, the bias manipulation was performed at two different levels of accurate old/new discrimination as the memory strength of old (studied) items was varied. In Experiment 3, the bias manipulation was added to another, bottom-up driven manipulation of bias induced via familiarity. In the first two Experiments, and in the low familiarity condition of Experiment 3, we found evidence of an early frontocentral ERP component at 320 ms poststimulus (the FN320) that was sensitive to the manipulation of bias via instruction, with more negative amplitudes indexing more liberal bias. By contrast, later during the trial (500–700 ms poststimulus), bias effects interacted with old/new effects across all three experiments. Results suggest that the decision criterion is typically activated early during recognition memory trials, and is integrated with retrieved memory signals and task-specific processing demands later during the trial. More generally, the findings demonstrate how ERPs can help to specify the dynamics of recognition memory processes under top-down and bottom-up controlled retrieval conditions. PMID

  20. Examining Event-Related Potential (ERP correlates of decision bias in recognition memory judgments.

    Directory of Open Access Journals (Sweden)

    Holger Hill

    Full Text Available Memory judgments can be based on accurate memory information or on decision bias (the tendency to report that an event is part of episodic memory when one is in fact unsure. Event related potentials (ERP correlates are important research tools for elucidating the dynamics underlying memory judgments but so far have been established only for investigations of accurate old/new discrimination. To identify the ERP correlates of bias, and observe how these interact with ERP correlates of memory, we conducted three experiments that manipulated decision bias within participants via instructions during recognition memory tests while their ERPs were recorded. In Experiment 1, the bias manipulation was performed between blocks of trials (automatized bias and compared to trial-by-trial shifts of bias in accord with an external cue (flexibly controlled bias. In Experiment 2, the bias manipulation was performed at two different levels of accurate old/new discrimination as the memory strength of old (studied items was varied. In Experiment 3, the bias manipulation was added to another, bottom-up driven manipulation of bias induced via familiarity. In the first two Experiments, and in the low familiarity condition of Experiment 3, we found evidence of an early frontocentral ERP component at 320 ms poststimulus (the FN320 that was sensitive to the manipulation of bias via instruction, with more negative amplitudes indexing more liberal bias. By contrast, later during the trial (500-700 ms poststimulus, bias effects interacted with old/new effects across all three experiments. Results suggest that the decision criterion is typically activated early during recognition memory trials, and is integrated with retrieved memory signals and task-specific processing demands later during the trial. More generally, the findings demonstrate how ERPs can help to specify the dynamics of recognition memory processes under top-down and bottom-up controlled retrieval conditions.

  1. A theoretical model for analysing gender bias in medicine

    Directory of Open Access Journals (Sweden)

    Johansson Eva E

    2009-08-01

    Full Text Available Abstract During the last decades research has reported unmotivated differences in the treatment of women and men in various areas of clinical and academic medicine. There is an ongoing discussion on how to avoid such gender bias. We developed a three-step-theoretical model to understand how gender bias in medicine can occur and be understood. In this paper we present the model and discuss its usefulness in the efforts to avoid gender bias. In the model gender bias is analysed in relation to assumptions concerning difference/sameness and equity/inequity between women and men. Our model illustrates that gender bias in medicine can arise from assuming sameness and/or equity between women and men when there are genuine differences to consider in biology and disease, as well as in life conditions and experiences. However, gender bias can also arise from assuming differences when there are none, when and if dichotomous stereotypes about women and men are understood as valid. This conceptual thinking can be useful for discussing and avoiding gender bias in clinical work, medical education, career opportunities and documents such as research programs and health care policies. Too meet the various forms of gender bias, different facts and measures are needed. Knowledge about biological differences between women and men will not reduce bias caused by gendered stereotypes or by unawareness of health problems and discrimination associated with gender inequity. Such bias reflects unawareness of gendered attitudes and will not change by facts only. We suggest consciousness-rising activities and continuous reflections on gender attitudes among students, teachers, researchers and decision-makers.

  2. A theoretical model for analysing gender bias in medicine.

    Science.gov (United States)

    Risberg, Gunilla; Johansson, Eva E; Hamberg, Katarina

    2009-08-03

    During the last decades research has reported unmotivated differences in the treatment of women and men in various areas of clinical and academic medicine. There is an ongoing discussion on how to avoid such gender bias. We developed a three-step-theoretical model to understand how gender bias in medicine can occur and be understood. In this paper we present the model and discuss its usefulness in the efforts to avoid gender bias. In the model gender bias is analysed in relation to assumptions concerning difference/sameness and equity/inequity between women and men. Our model illustrates that gender bias in medicine can arise from assuming sameness and/or equity between women and men when there are genuine differences to consider in biology and disease, as well as in life conditions and experiences. However, gender bias can also arise from assuming differences when there are none, when and if dichotomous stereotypes about women and men are understood as valid. This conceptual thinking can be useful for discussing and avoiding gender bias in clinical work, medical education, career opportunities and documents such as research programs and health care policies. Too meet the various forms of gender bias, different facts and measures are needed. Knowledge about biological differences between women and men will not reduce bias caused by gendered stereotypes or by unawareness of health problems and discrimination associated with gender inequity. Such bias reflects unawareness of gendered attitudes and will not change by facts only. We suggest consciousness-rising activities and continuous reflections on gender attitudes among students, teachers, researchers and decision-makers.

  3. Exposure to sexism can decrease implicit gender stereotype bias

    NARCIS (Netherlands)

    Ramos, Miguel R.; Barreto, Manuela; Ellemers, Naomi; Moya, Miguel; Ferreira, Lucia; Calanchini, Jimmy

    Two studies examined the effect of exposure to sexism on implicit gender bias, focusing specifically on stereotypes of men as competent and women as warm. Male and female participants were exposed to sexism or no sexism. In both Experiment 1 (Implicit Association Task; N = 115) and Experiment 2

  4. Biases in affective forecasting and recall in individuals with depression and anxiety symptoms.

    Science.gov (United States)

    Wenze, Susan J; Gunthert, Kathleen C; German, Ramaris E

    2012-07-01

    The authors used experience sampling to investigate biases in affective forecasting and recall in individuals with varying levels of depression and anxiety symptoms. Participants who were higher in depression symptoms demonstrated stronger (more pessimistic) negative mood prediction biases, marginally stronger negative mood recall biases, and weaker (less optimistic) positive mood prediction and recall biases. Participants who were higher in anxiety symptoms demonstrated stronger negative mood prediction biases, but positive mood prediction biases that were on par with those who were lower in anxiety. Anxiety symptoms were not associated with mood recall biases. Neither depression symptoms nor anxiety symptoms were associated with bias in event prediction. Their findings fit well with the tripartite model of depression and anxiety. Results are also consistent with the conceptualization of anxiety as a "forward-looking" disorder, and with theories that emphasize the importance of pessimism and general negative information processing in depressive functioning.

  5. New Trends in Magnetic Exchange Bias

    Science.gov (United States)

    Mougin, Alexandra; Mangin, Stéphane; Bobo, Jean-Francois; Loidl, Alois

    2005-05-01

    -of-plane exchange bias, depending on the field cooling direction. This is of particular interest since it allows probing of the three-dimensional spin structure of the AF layer. The interface magnetic configuration is extremely important in the perpendicular geometry, as the short-range exchange coupling competes with a long-range dipolar interaction; the induced uniaxial anisotropy must overcome the demagnetization energy to establish perpendicular anisotropy films. Those new studies are of primary importance for the magnetic media industry as perpendicular recording exhibits potential for strongly increased storage densities. 3. Parameters tuning exchange bias in polycrystalline samples and magnetic configurations: Different parameters can be used to tune the exchange bias coupling in polycrystalline samples similar to those used in devices. Particularly fascinating aspects are the questions of the appearance of exchange bias or coercivity in ferromagnet/antiferromagnet heterostructures, and its relation to magnetic configurations formed on either side of the interface. Several papers report on either growth choices or post preparation treatments that enable tuning of the exchange bias in bilayers. The additional complexity and novel features of the exchange coupled interface make the problem particularly rich. 4. Dynamics and magnetization reversal: Linear response experiments, such as ferromagnetic resonance, have been used with great success to identify interface, surface anisotropies and interlayer exchange in multilayer systems. The exchange bias structure is particularly well suited to study because interface driven changes in the spin wave frequencies in the ferromagnet can be readily related to interlayer exchange and anisotropy parameters associated with the antiferromagnet. Because the exchange bias is intimately connected with details of the magnetization process during reversal and the subsequent formation of hysteresis, considerations of time dependence and

  6. Plasma structures in front of a floated emissive electrode

    International Nuclear Information System (INIS)

    Ishiguro, S.; Sato, N.

    1993-01-01

    A particle simulation with plasma source is carried out on plasma structures generated by an electron emissive electrode floated in a collisionless plasma. When low-temperature, high-density thermal electrons are emitted, there appears a negative potential dip in front of the electrode, which is always accompanied by a low-frequency oscillation. On the other hand, three regimes of plasma structures appear for an electron beam injection. When a high-flux electron beam is injected, an electron sheath is generated in front of the electrode. The sheath reflects ions flowing to the electrode, providing an increase in the plasma density. When a low-flux electron beam is injected, no electron sheath is generated. When an intermediate-flux beam is injected, the electron sheath structure appears periodically in time. The lifetime of the sheath is proportional to the system length. These results of beam injection are almost consistent with those of a Q-machine experiment

  7. The electrochemical Peltier heat of the standard hydrogen electrode reaction

    International Nuclear Information System (INIS)

    Fang Zheng; Wang Shaofen; Zhang Zhenghua; Qiu Guanzhou

    2008-01-01

    A method for measuring the electrochemical Peltier heat (EPH) of a single electrode reaction has been developed and an absolute scale is suggested to obtain EPH of the standard hydrogen electrode. The scale is based on φ 0 * = 0 and ΔS 0 * = 0 for any electrode reaction at zero Kelvin, in accord with the third law of thermodynamics. The relationships between entropy, enthalpy and free energy changes on this scale and on the conventional scale are derived. Calorimetric experiments were made on the Fe(CN) 6 3- /Fe(CN) 6 4- system at five different concentrations at 298.15 K, and EPH for the standard hydrogen electrode reaction is obtained. EPHs and the entropy change on the absolute scale for the studied redox are linearly related to concentration of electrolyte. The reversible electric work is almost concentration independent in the range of concentration studied

  8. Recovery Of Electrodic Powder From Spent Lithium Ion Batteries (LIBs

    Directory of Open Access Journals (Sweden)

    Shin S.M.

    2015-06-01

    Full Text Available This study was focused on recycling process newly proposed to recover electrodic powder enriched in cobalt (Co and lithium (Li from spent lithium ion battery. In addition, this new process was designed to prevent explosion of batteries during thermal treatment under inert atmosphere. Spent lithium ion batteries (LIBs were heated over the range of 300°C to 600°C for 2 hours and each component was completely separated inside reactor after experiment. Electrodic powder was successfully recovered from bulk components containing several pieces of metals through sieving operation. The electrodic powder obtained was examined by X-ray diffraction (XRD, energy dispersive X-ray spectroscopy (EDS, and atomic absorption spectroscopy (AA and furthermore image of the powder was taken by scanning electron microscopy (SEM. It was finally found that cobalt and lithium were mainly recovered to about 49 wt.% and 4 wt.% in electrodic powder, respectively.

  9. Bias polarity-sensitive electrical failure characteristics of ZnSe nanowire in metal–semiconductor–metal nanostructure

    Directory of Open Access Journals (Sweden)

    Yu Tan

    2014-04-01

    Full Text Available The effect of bias polarity on the electrical breakdown behavior of the single ZnSe nanowire (NW in the metal–semiconductor–metal (M–S–M nanostructure under high current density and high bias conditions has been studied in the present paper. The experimental results show that the failure of the ZnSe NW in M–S–M nanostructure was sensitive to bias polarity since the NW commonly collapsed at the negatively biased Au metal electrode due to high Joule heat produced in NW at the reversely biased Schottky barrier. Thus, the electrical breakdown behavior of the ZnSe NW was highly dominated by the cathode-controlled mode due to the high resistance of the depletion region of ZnSe NW at the reversely biased Schottky contact.

  10. High voltage performance of a dc photoemission electron gun with centrifugal barrel-polished electrodes

    Science.gov (United States)

    Hernandez-Garcia, C.; Bullard, D.; Hannon, F.; Wang, Y.; Poelker, M.

    2017-09-01

    The design and fabrication of electrodes for direct current (dc) high voltage photoemission electron guns can significantly influence their performance, most notably in terms of maximum achievable bias voltage. Proper electrostatic design of the triple-point junction shield electrode minimizes the risk of electrical breakdown (arcing) along the insulator-cable plug interface, while the electrode shape is designed to maintain work, we describe a centrifugal barrel-polishing technique commonly used for polishing the interior surface of superconducting radio frequency cavities but implemented here for the first time to polish electrodes for dc high voltage photoguns. The technique reduced polishing time from weeks to hours while providing surface roughness comparable to that obtained with diamond-paste polishing and with unprecedented consistency between different electrode samples. We present electrode design considerations and high voltage conditioning results to 360 kV (˜11 MV/m), comparing barrel-polished electrode performance to that of diamond-paste polished electrodes. Tests were performed using a dc high voltage photogun with an inverted-geometry ceramic insulator design.

  11. Negativity Bias in Dangerous Drivers.

    Directory of Open Access Journals (Sweden)

    Jing Chai

    Full Text Available The behavioral and cognitive characteristics of dangerous drivers differ significantly from those of safe drivers. However, differences in emotional information processing have seldom been investigated. Previous studies have revealed that drivers with higher anger/anxiety trait scores are more likely to be involved in crashes and that individuals with higher anger traits exhibit stronger negativity biases when processing emotions compared with control groups. However, researchers have not explored the relationship between emotional information processing and driving behavior. In this study, we examined the emotional information processing differences between dangerous drivers and safe drivers. Thirty-eight non-professional drivers were divided into two groups according to the penalty points that they had accrued for traffic violations: 15 drivers with 6 or more points were included in the dangerous driver group, and 23 drivers with 3 or fewer points were included in the safe driver group. The emotional Stroop task was used to measure negativity biases, and both behavioral and electroencephalograph data were recorded. The behavioral results revealed stronger negativity biases in the dangerous drivers than in the safe drivers. The bias score was correlated with self-reported dangerous driving behavior. Drivers with strong negativity biases reported having been involved in mores crashes compared with the less-biased drivers. The event-related potentials (ERPs revealed that the dangerous drivers exhibited reduced P3 components when responding to negative stimuli, suggesting decreased inhibitory control of information that is task-irrelevant but emotionally salient. The influence of negativity bias provides one possible explanation of the effects of individual differences on dangerous driving behavior and traffic crashes.

  12. Cognitive constraints increase estimation biases: Cognitive load and delay in judgments

    OpenAIRE

    Allred, Sarah; Crawford, L. Elizabeth; Duffy, Sean; Smith, John

    2014-01-01

    Previous work has demonstrated that memory for simple stimuli can be biased by information about the category of which the stimulus is a member. These biases have been interpreted as optimally integrating noisy sensory information with category information. A separate literature has demonstrated that cognitive load can lead to biases in social cognition. Here we link the two, asking whether delay (Experiment 1) and cognitive load (Experiment 2) affect the extent to which observers' memories f...

  13. Preparation and characterization of PbO2–ZrO2 nanocomposite electrodes

    International Nuclear Information System (INIS)

    Yao Yingwu; Zhao Chunmei; Zhu Jin

    2012-01-01

    PbO 2 –ZrO 2 nanocomposite electrodes were prepared by the anodic codeposition in the lead nitrate plating bath containing ZrO 2 nanoparticles. The influences of the ZrO 2 nanoparticles concentration, current density, temperature and stirring rate of the plating bath on the composition of the nanocomposite electrodes were investigated. The surface morphology and the structure of the nanocomposite electrodes were characterized by scanning electronic microscopy (SEM) and X-ray diffraction (XRD), respectively. The experimental results show that the addition of ZrO 2 nanoparticles in the electrodeposition process of lead dioxide significantly increases the lifetime of nanocomposite electrodes. The PbO 2 –ZrO 2 nanocomposite electrodes have a service life of 141 h which is almost four times longer than that of the pure PbO 2 electrodes. The morphology of PbO 2 –ZrO 2 nanocomposite electrodes is more compact and finer than that of PbO 2 electrodes. The relative surface area of the composite electrodes is approximately 2 times that of the pure PbO 2 electrodes. The structure test shows that the addition of ZrO 2 nanoparticles into the plating bath decreases the grain size of the PbO 2 –ZrO 2 nanocomposite electrodes. The anodic polarization curves show that the oxygen evolution overpotential of PbO 2 –ZrO 2 nanocomposite electrodes is higher than PbO 2 electrodes. The pollutant anodic oxidation experiment show that the PbO 2 –ZrO 2 nanocomposite electrode exhibited the better performance for the degradation of 4-chlorophenol than PbO 2 electrode, the removal ratio of COD reached 96.2%.

  14. Affective bias in visual working memory is associated with capacity.

    Science.gov (United States)

    Xie, Weizhen; Li, Huanhuan; Ying, Xiangyu; Zhu, Shiyou; Fu, Rong; Zou, Yingmin; Cui, Yanyan

    2017-11-01

    How does the affective nature of task stimuli modulate working memory (WM)? This study investigates whether WM maintains emotional information in a biased manner to meet the motivational principle of approaching positivity and avoiding negativity by retaining more approach-related positive content over avoidance-related negative content. This bias may exist regardless of individual differences in WM functionality, as indexed by WM capacity (overall bias hypothesis). Alternatively, this bias may be contingent on WM capacity (capacity-based hypothesis), in which a better WM system may be more likely to reveal an adaptive bias. In two experiments, participants performed change localisation tasks with emotional and non-emotional stimuli to estimate the number of items that they could retain for each of those stimuli. Although participants did not seem to remember one type of emotional content (e.g. happy faces) better than the other type of emotional content (e.g. sad faces), there was a significant correlation between WM capacity and affective bias. Specifically, participants with higher WM capacity for non-emotional stimuli (colours or line-drawing symbols) tended to maintain more happy faces over sad faces. These findings demonstrated the presence of a "built-in" affective bias in WM as a function of its systematic limitations, favouring the capacity-based hypothesis.

  15. Bias in the Flesh

    Science.gov (United States)

    Messing, Solomon; Jabon, Maria; Plaut, Ethan

    2016-01-01

    There is strong evidence linking skin complexion to negative stereotypes and adverse real-world outcomes. We extend these findings to political ad campaigns, in which skin complexion can be easily manipulated in ways that are difficult to detect. Devising a method to measure how dark a candidate appears in an image, this paper examines how complexion varied with ad content during the 2008 presidential election campaign (study 1). Findings show that darker images were more frequent in negative ads—especially those linking Obama to crime—which aired more frequently as Election Day approached. We then conduct an experiment to document how these darker images can activate stereotypes, and show that a subtle darkness manipulation is sufficient to activate the most negative stereotypes about Blacks—even when the candidate is a famous counter-stereotypical exemplar—Barack Obama (study 2). Further evidence of an evaluative penalty for darker skin comes from an observational study measuring affective responses to depictions of Obama with varying skin complexion, presented via the Affect Misattribution Procedure in the 2008 American National Election Study (study 3). This study demonstrates that darker images are used in a way that complements ad content, and shows that doing so can negatively affect how individuals evaluate candidates and think about politics. PMID:27257306

  16. Gate-dependent asymmetric transport characteristics in pentacene barristors with graphene electrodes.

    Science.gov (United States)

    Hwang, Wang-Taek; Min, Misook; Jeong, Hyunhak; Kim, Dongku; Jang, Jingon; Yoo, Daekyung; Jang, Yeonsik; Kim, Jun-Woo; Yoon, Jiyoung; Chung, Seungjun; Yi, Gyu-Chul; Lee, Hyoyoung; Wang, Gunuk; Lee, Takhee

    2016-11-25

    We investigated the electrical characteristics and the charge transport mechanism of pentacene vertical hetero-structures with graphene electrodes. The devices are composed of vertical stacks of silicon, silicon dioxide, graphene, pentacene, and gold. These vertical heterojunctions exhibited distinct transport characteristics depending on the applied bias direction, which originates from different electrode contacts (graphene and gold contacts) to the pentacene layer. These asymmetric contacts cause a current rectification and current modulation induced by the gate field-dependent bias direction. We observed a change in the charge injection barrier during variable-temperature current-voltage characterization, and we also observed that two distinct charge transport channels (thermionic emission and Poole-Frenkel effect) worked in the junctions, which was dependent on the bias magnitude.

  17. Probing Electrode Heterogeneity Using Fourier-Transformed Alternating Current Voltammetry: Application to a Dual-Electrode Configuration.

    Science.gov (United States)

    Tan, Sze-Yin; Unwin, Patrick R; Macpherson, Julie V; Zhang, Jie; Bond, Alan M

    2017-03-07

    Quantitative studies of electron transfer processes at electrode/electrolyte interfaces, originally developed for homogeneous liquid mercury or metallic electrodes, are difficult to adapt to the spatially heterogeneous nanostructured electrode materials that are now commonly used in modern electrochemistry. In this study, the impact of surface heterogeneity on Fourier-transformed alternating current voltammetry (FTACV) has been investigated theoretically under the simplest possible conditions where no overlap of diffusion layers occurs and where numerical simulations based on a 1D diffusion model are sufficient to describe the mass transport problem. Experimental data that meet these requirements can be obtained with the aqueous [Ru(NH 3 ) 6 ] 3+/2+ redox process at a dual-electrode system comprised of electrically coupled but well-separated glassy carbon (GC) and boron-doped diamond (BDD) electrodes. Simulated and experimental FTACV data obtained with this electrode configuration, and where distinctly different heterogeneous charge transfer rate constants (k 0 values) apply at the individual GC and BDD electrode surfaces, are in excellent agreement. Principally, because of the far greater dependence of the AC current magnitude on k 0 , it is straightforward with the FTACV method to resolve electrochemical heterogeneities that are ∼1-2 orders of magnitude apart, as applies in the [Ru(NH 3 ) 6 ] 3+/2+ dual-electrode configuration experiments, without prior knowledge of the individual kinetic parameters (k 0 1 and k 0 2 ) or the electrode size ratio (θ 1 :θ 2 ). In direct current voltammetry, a difference in k 0 of >3 orders of magnitude is required to make this distinction.

  18. ELECTROD FLUOR-SELECTIV

    Directory of Open Access Journals (Sweden)

    Mariana DÎRU

    2018-03-01

    Full Text Available A fost preparat un senzor anionic specific, bazat pe pivalatul trinuclear al cromului(III ca material electro­activ încorporat în membrana PVC plastifiată. Senzorul prezintă răspuns Nernstian (55,78 mV/decadă în intervalul de concentrație 10-1-10-4 mol/L cu limita de detecție 2,0∙10-5 mol/L pentru anionul fluorură. Domeniul optim de pH de funcţionare a electrodului asamblat este ˃5. Senzorul dat are un timp de răspuns de 30-60 s și reproductibilitatea rezultatelor se menține timp de 3 luni. Coeficienții potențiometrici ai selectivității au fost determinați prin metoda soluțiilor separate. A fost realizată aplicarea acestor electrozi la analiza pastei de dinți ce conține fluorură și rezultatele experimentale au fost comparate cu datele de pe prospect.FLUORIDE-SELECTIVE ELECTRODEA specific anionic sensor has been prepared, based on trinuclearchromium(III pivalate as sensing material incorpo­rated into the plasticized PVC-membrane. The sensor exhibited Nernstian response (55,78 mV/decade in the region between 10-1-10-4 mol/L with a detection limit of 2,0∙10-5 mol/L for fluoride. The working pH of the electrode was in the 5-6 range. The sensor has a response time 30-60 s and can be used for least 3 month. The potentiometric selectivity coefficients were determined by separate solution method. Application of these electrodes to the analysis of toothpaste containing fluoride has been realized and experimental results have been compared with the data on the prospectus.

  19. Capacitance enhancement via electrode patterning

    International Nuclear Information System (INIS)

    Ho, Tuan A.; Striolo, Alberto

    2013-01-01

    The necessity of increasing the energy density in electric double layer capacitors to meet current demand is fueling fundamental and applied research alike. We report here molecular dynamics simulation results for aqueous electrolytes near model electrodes. Particular focus is on the effect of electrode patterning on the structure of interfacial electrolytes, and on the potential drop between the solid electrodes and the bulk electrolytes. The latter is estimated by numerically integrating the Poisson equation using the charge densities due to water and ions accumulated near the interface as input. We considered uniform and patterned electrodes, both positively and negatively charged. The uniformly charged electrodes are modeled as graphite. The patterned ones are obtained by removing carbon atoms from the top-most graphene layer, yielding nanoscopic squares and stripes patterns. For simplicity, the patterned electrodes are effectively simulated as insulators (the charge remains localized on the top-most layer of carbon atoms). Our simulations show that the patterns alter the structure of water and the accumulation of ions at the liquid-solid interfaces. Using aqueous NaCl solutions, we found that while the capacitance calculated for three positively charged electrodes did not change much, that calculated for the negatively charged electrodes significantly increased upon patterning. We find that both water structure and orientation, as well as ion accumulation affect the capacitance. As electrode patterning affects differently water structure and ion accumulation, it might be possible to observe ion-specific effects. These results could be useful for advancing our understanding of electric double layer capacitors, capacitive desalination processes, as well as of fundamental interfacial electrolytes properties

  20. Studies of pyrrole black electrodes as possible battery positive electrodes

    Energy Technology Data Exchange (ETDEWEB)

    Mengoli, G.; Musiani, M.M.; Fleischmann, M.; Pletcher, D.

    1984-05-01

    It is shown that a polypyrrole, pyrrole black, may be formed anodically in several aqueous acids. The polypyrrole film shows a redox couple at less positive potentials than that required to form the film and the charge associated with these reduction and oxidation processes together with their stabilty to cycling varies with the anion in solution and the potential where the polypyrrole is formed; over-oxidation of the film caused by taking its potential too positive has a particularly disadvantageous affect. In the acids HBr and HI, the polypyrrole films can act as a storage medium for Br/sub 2/ or I/sub 2/ so that they may be used as a substrate for a X/sub 2//X/sup -/ electrode. Such electrodes may be charge/discharge cycled and the pyrrole/Br/sub 2/ electrode shows promise as a battery positive electrode.

  1. Understanding the tropical warm temperature bias simulated by climate models

    Science.gov (United States)

    Brient, Florent; Schneider, Tapio

    2017-04-01

    The state-of-the-art coupled general circulation models have difficulties in representing the observed spatial pattern of surface tempertaure. A majority of them suffers a warm bias in the tropical subsiding regions located over the eastern parts of oceans. These regions are usually covered by low-level clouds scattered from stratus along the coasts to more vertically developed shallow cumulus farther from them. Models usually fail to represent accurately this transition. Here we investigate physical drivers of this warm bias in CMIP5 models through a near-surface energy budget perspective. We show that overestimated solar insolation due to a lack of stratocumulus mostly explains the warm bias. This bias also arises partly from inter-model differences in surface fluxes that could be traced to differences in near-surface relative humidity and air-sea temperature gradient. We investigate the role of the atmosphere in driving surface biases by comparing historical and atmopsheric (AMIP) experiments. We show that some differences in boundary-layer characteristics, mostly those related to cloud fraction and relative humidity, are already present in AMIP experiments and may be the drivers of coupled biases. This gives insights in how models can be improved for better simulations of the tropical climate.

  2. Transmission of Cognitive Bias and Fear From Parents to Children: An Experimental Study.

    Science.gov (United States)

    Remmerswaal, Danielle; Muris, Peter; Huijding, Jorg

    2016-01-01

    This study explored the role of parents in the development of a cognitive bias and subsequent fear levels in children. In Experiment 1, nonclinical children ages 8-13 (N = 122) underwent a training during which they worked together with their mothers on an information search task. Mothers received instructions to induce either a positive or negative information search bias in their children. Experiment 2 investigated to what extent mothers own cognitive bias predicted children's information search bias. Mothers of 49 nonclinical children ages 9-12 received no explicit training instructions before working together with their child on an information search task. Experiment 1 demonstrated that mothers had a significant impact on children's cognitive bias and fear. More precisely, children who had received a negative parental training displayed an increase in negative information search bias and fear, whereas children who had received a positive parental training showed an increase in positive information search bias and a decrease in fear. In Experiment 2, it was found that children's information search biases after working together with their mothers were predicted by their mothers' initial cognitive bias scores. These findings can be taken as support for the intergenerational transmission of cognitive biases from mothers to children.

  3. The self-attribution bias and paranormal beliefs.

    Science.gov (United States)

    van Elk, Michiel

    2017-03-01

    The present study investigated the relation between paranormal beliefs, illusory control and the self-attribution bias, i.e., the motivated tendency to attribute positive outcomes to oneself while negative outcomes are externalized. Visitors of a psychic fair played a card guessing game and indicated their perceived control over randomly selected cards as a function of the congruency and valence of the card. A stronger self-attribution bias was observed for paranormal believers compared to skeptics and this bias was specifically related to traditional religious beliefs and belief in superstition. No relation between paranormal beliefs and illusory control was found. Self-report measures indicated that paranormal beliefs were associated to being raised in a spiritual family and to anomalous experiences during childhood. Thereby this study suggests that paranormal beliefs are related to specific cognitive biases that in turn are shaped by socio-cultural factors. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Reflective Practice: How the World Bank Explored Its Own Biases?

    Science.gov (United States)

    McKee, Martin; Stuckler, David

    2015-12-10

    While many international organisations have independent evaluations, including the International Monetary Fund (IMF) and World Health organization (WHO), uniquely the World Bank in its 2015 World Development Report sought to ascertain the potential biases that influence how its staff interpret evidence and influence policy. Here, we describe the World Bank's study design, including experiments to ascertain the impact on Bank staff's judgements of complexity, confirmation bias, sunk cost bias, and an understanding of the wishes of those whom they seek to help. We then review the Bank's proposed mechanisms to minimise the impact of the biases they identified. We argue that this approach, that we refer to as 'reflective practice,' deserves to be adopted more widely among institutions that seek to use evidence from research to inform policy and practice. © 2016 by Kerman University of Medical Sciences.

  5. Working memory biasing of visual perception without awareness.

    Science.gov (United States)

    Pan, Yi; Lin, Bingyuan; Zhao, Yajun; Soto, David

    2014-10-01

    Previous research has demonstrated that the contents of visual working memory can bias visual processing in favor of matching stimuli in the scene. However, the extent to which such top-down, memory-driven biasing of visual perception is contingent on conscious awareness remains unknown. Here we showed that conscious awareness of critical visual cues is dispensable for working memory to bias perceptual selection mechanisms. Using the procedure of continuous flash suppression, we demonstrated that "unseen" visual stimuli during interocular suppression can gain preferential access to awareness if they match the contents of visual working memory. Strikingly, the very same effect occurred even when the visual cue to be held in memory was rendered nonconscious by masking. Control experiments ruled out the alternative accounts of repetition priming and different detection criteria. We conclude that working memory biases of visual perception can operate in the absence of conscious awareness.

  6. Comparative risk perception and foods: The impact of optimistic bias on risk communication and health promotion

    NARCIS (Netherlands)

    Miles, S.; Frewer, L.J.

    2003-01-01

    Optimistic bias is a phenomenon in which people believe they are less likely to experience negative events, and more likely to experience positive ones, than other people. There is evidence that optimistic bias reduces people's motivation to undertake self-protective behaviour, as well as reducing

  7. Large Magnetoresistance at High Bias Voltage in Double-layer Organic Spin Valves

    Science.gov (United States)

    Subedi, R. C.; Liang, S. H.; Geng, R.; Zhang, Q. T.; Lou, L.; Wang, J.; Han, X. F.; Nguyen, T. D.

    We report studies of magnetoresistance (MR) in double-layer organic spin valves (DOSV) using tris (8-hydroxyquinolinato) aluminum (Alq3) spacers. The device exhibits three distinct resistance levels depending on the relative magnetizations of the ferromagnetic electrodes. We observed a much weaker bias voltage dependence of MR in the device compared to that in the conventional organic spin valve (OSV). The MR magnitude reduces by the factor of two at 0.7 V bias voltage in the DOSV compared to 0.02 V in the conventional OSV. Remarkably, the MR magnitude reaches 0.3% at 6 V bias in the DOSVs, the largest MR response ever reported in OSVs at this bias. Our finding may have a significant impact on achieving high efficient bipolar OSVs strictly performed at high voltages. University of Georgia start-up fund, Ministry of Education, Singapore, National Natural Science Foundation of China.

  8. Challenging stereotyping and bias: a voice simulation study.

    Science.gov (United States)

    Dearing, Karen S; Steadman, Sheryl

    2008-02-01

    Stigma is a barrier to mental health care access for patients with schizophrenia and can interfere with developing therapeutic relationships. This study demonstrates success of a voice simulation experience during orientation in changing the biases of nursing students and the effect on the development of the nurse-patient relationship. Ninety-four individuals participated; 52 received a voice simulation experience during orientation, and 42 received orientation with no voice simulation experience. The Medical Condition Regard Scale was administered before and after orientation. Posttest paired t test results show significant differences in attitudes toward patients with voice hearing experiences between the two groups. The themes of personal growth from the focus groups postorientation include Affective Experience, Physical Experience, and Empathy. Findings demonstrate that the orientation process should include methods to challenge stereotyping and bias to decrease stigma, improve service access, and enhance the ability to develop therapeutic relationships.

  9. News Consumption and Media Bias

    OpenAIRE

    Yi Xiang; Miklos Sarvary

    2007-01-01

    Bias in the market for news is well-documented. Recent research in economics explains the phenomenon by assuming that consumers want to read (watch) news that is consistent with their tastes or prior beliefs rather than the truth. The present paper builds on this idea but recognizes that (i) besides “biased” consumers, there are also “conscientious” consumers whose sole interest is in discovering the truth, and (ii) consistent with reality, media bias is constrained by the truth. These two fa...

  10. How we categorize objects is related to how we remember them: The shape bias as a memory bias

    Science.gov (United States)

    Vlach, Haley A.

    2016-01-01

    The “shape bias” describes the phenomenon that, after a certain point in development, children and adults generalize object categories based upon shape to a greater degree than other perceptual features. The focus of research on the shape bias has been to examine the types of information that learners attend to in one moment in time. The current work takes a different approach by examining whether learners' categorical biases are related to their retention of information across time. In three experiments, children's (N = 72) and adults' (N = 240) memory performance for features of objects was examined in relation to their categorical biases. The results of these experiments demonstrated that the number of shape matches chosen during the shape bias task significantly predicted shape memory. Moreover, children and adults with a shape bias were more likely to remember the shape of objects than they were the color and size of objects. Taken together, this work suggests the development of a shape bias may engender better memory for shape information. PMID:27454236

  11. Fractals in several electrode materials

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Chunyong, E-mail: zhangchy@njau.edu.cn [Department of Chemistry, College of Science, Nanjing Agricultural University, Nanjing 210095 (China); Suzhou Key Laboratory of Environment and Biosafety, Suzhou Academy of Southeast University, Dushuhu lake higher education town, Suzhou 215123 (China); Wu, Jingyu [Department of Chemistry, College of Science, Nanjing Agricultural University, Nanjing 210095 (China); Fu, Degang [Suzhou Key Laboratory of Environment and Biosafety, Suzhou Academy of Southeast University, Dushuhu lake higher education town, Suzhou 215123 (China); State Key Laboratory of Bioelectronics, Southeast University, Nanjing 210096 (China)

    2014-09-15

    Highlights: • Fractal geometry was employed to characterize three important electrode materials. • The surfaces of all studied electrodes were proved to be very rough. • The fractal dimensions of BDD and ACF were scale dependent. • MMO film was more uniform than BDD and ACF in terms of fractal structures. - Abstract: In the present paper, the fractal properties of boron-doped diamond (BDD), mixed metal oxide (MMO) and activated carbon fiber (ACF) electrode have been studied by SEM imaging at different scales. Three materials are self-similar with mean fractal dimension in the range of 2.6–2.8, confirming that they all exhibit very rough surfaces. Specifically, it is found that MMO film is more uniform in terms of fractal structure than BDD and ACF. As a result, the intriguing characteristics make these electrodes as ideal candidates for high-performance decontamination processes.

  12. Electrode materials for rechargeable batteries

    Science.gov (United States)

    Abouimrane, Ali; Amine, Khalil

    2015-04-14

    Selenium or selenium-containing compounds may be used as electroactive materials in electrodes or electrochemical devices. The selenium or selenium-containing compound is mixed with a carbon material.

  13. The coalitional value theory of antigay bias

    NARCIS (Netherlands)

    Winegard, Bo; Reynolds, Tania; Baumeister, Roy F.; Plant, E. Ashby

    2016-01-01

    Research indicates that antigay bias follows a specific pattern (and probably has throughout written history, at least in the West): (a) men evince more antigay bias than women; (b) men who belong to traditionally male coalitions evince more antigay bias than those who do not; (c) antigay bias is

  14. Composite Electrodes for Electrochemical Supercapacitors

    OpenAIRE

    Li, Jun; Yang, QuanMin; Zhitomirsky, Igor

    2010-01-01

    Abstract Manganese dioxide nanofibers with length ranged from 0.1 to 1 μm and a diameter of about 4–6 nm were prepared by a chemical precipitation method. Composite electrodes for electrochemical supercapacitors were fabricated by impregnation of the manganese dioxide nanofibers and multiwalled carbon nanotubes (MWCNT) into porous Ni plaque current collectors. Obtained composite electrodes, containing 85% of manganese dioxide and 15 mass% of MWCNT, as a conductive additive, with to...

  15. Surgical implications of perimodiolar cochlear implant electrode design: avoiding intracochlear damage and scala vestibuli insertion.

    Science.gov (United States)

    Briggs, R J; Tykocinski, M; Saunders, E; Hellier, W; Dahm, M; Pyman, B; Clark, G M

    2001-09-01

    To review the mechanisms and nature of intracochlear damage associated with cochlear implant electrode array insertion, in particular, the various perimodiolar electrode designs. Make recommendations regarding surgical techniques for the Nucleus Contour electrode to ensure correct position and minimal insertion trauma. The potential advantages of increased modiolar proximity of intracochlear multichannel electrode arrays are a reduction in stimulation thresholds, an increase in dynamic range and more localized neural excitation. This may improve speech perception and reduce power consumption. These advantages may be negated if increased intracochlear damage results from the method used to position the electrodes close to the modiolus. A review of the University of Melbourne Department of Otolaryngology experience with temporal bone safety studies using the Nucleus standard straight electrode array and a variety of perimodiolar electrode array designs; comparison with temporal bone insertion studies from other centres and postmortem histopathology studies reported in the literature. Review of our initial clinical experience using the Nucleus Contour electrode array. The nature of intracochlear damage resulting from electrode insertion trauma ranges from minor, localized, spiral ligament tear to diffuse organ of Corti disruption and osseous spiral lamina fracture. The type of damage depends on the mechanical characteristics of the electrode array, the stiffness, curvature and size of the electrode in relation to the scala, and the surgical technique. The narrow, flexible, straight arrays are the least traumatic. Pre-curved or stiffer arrays are associated with an incidence of basilar membrane perforation. The cochleostomy must be correctly sited in relation to the round window to ensure scala tympani insertion. A cochleostomy anterior to the round window rather than inferior may lead to scala media or scala vestibuli insertion. Proximity of electrodes to the modiolus

  16. Cognitive bias in forensic anthropology: visual assessment of skeletal remains is susceptible to confirmation bias.

    Science.gov (United States)

    Nakhaeizadeh, Sherry; Dror, Itiel E; Morgan, Ruth M

    2014-05-01

    An experimental study was designed to examine cognitive biases within forensic anthropological non-metric methods in assessing sex, ancestry and age at death. To investigate examiner interpretation, forty-one non-novice participants were semi randomly divided into three groups. Prior to conducting the assessment of the skeletal remains, two of the groups were given different extraneous contextual information regarding the sex, ancestry and age at death of the individual. The third group acted as a control group with no extraneous contextual information. The experiment was designed to investigate if the interpretation and conclusions of the skeletal remains would differ amongst participants within the three groups, and to assess whether the examiners would confirm or disagree with the given extraneous context when establishing a biological profile. The results revealed a significant biasing effect within the three groups, demonstrating a strong confirmation bias in the assessment of sex, ancestry and age at death. In assessment of sex, 31% of the participants in the control group concluded that the skeleton remains were male. In contrast, in the group that received contextual information that the remains were male, 72% concluded that the remains were male, and in the participant group where the context was that the remains were of a female, 0% of the participants concluded that the remains were male. Comparable results showing bias were found in assessing ancestry and age at death. These data demonstrate that cognitive bias can impact forensic anthropological non-metric methods on skeletal remains and affects the interpretation and conclusions of the forensic scientists. This empirical study is a step in establishing an evidence base approach for dealing with cognitive issues in forensic anthropological assessments, so as to enhance this valuable forensic science discipline. Copyright © 2013 Forensic Science Society. Published by Elsevier Ireland Ltd. All rights

  17. Development of DBD plasma actuators: The double encapsulated electrode

    Science.gov (United States)

    Erfani, Rasool; Zare-Behtash, Hossein; Hale, Craig; Kontis, Konstantinos

    2015-04-01

    Plasma actuators are electrical devices that generate a wall bounded jet without the use of any moving parts. For aerodynamic applications they can be used as flow control devices to delay separation and augment lift on a wing. The standard plasma actuator consists of a single encapsulated (ground) electrode. The aim of this project is to investigate the effect of varying the number and distribution of encapsulated electrodes in the dielectric layer. Utilising a transformer cascade, a variety of input voltages are studied for their effect. In the quiescent environment of a Faraday cage the velocity flow field is recorded using particle image velocimetry. Through understanding of the mechanisms involved in producing the wall jet and the importance of the encapsulated electrode a novel actuator design is proposed. The actuator design distributes the encapsulated electrode throughout the dielectric layer. The experiments have shown that actuators with a shallow initial encapsulated electrode induce velocities greater than the baseline case at the same voltage. Actuators with a deep initial encapsulated electrode are able to induce the highest velocities as they can operate at higher voltages without breakdown of the dielectric.

  18. Amodiaquine polymeric membrane electrode.

    Science.gov (United States)

    Malongo, T Kimbeni; Blankert, B; Kambu, O; Amighi, K; Nsangu, J; Kauffmann, J-M

    2006-04-11

    The construction and electrochemical response characteristics of two types of poly(vinyl chloride) (PVC) membrane sensors for the determination of amodiaquine hydrochloride (ADQ.2HCl) are described. The sensing membrane comprised an ion-pair formed between the cationic drug and sodium tetraphenyl borate (NaTPB) or potassium tetrakis(4-chlorophenyl) borate (KTCPB) in a plasticized PVC matrix. Eight PVC membrane ion-selective electrodes were fabricated and studied. Several plasticizers were studied namely, dioctyl phthalate (DOP), 2-nitrophenyl octyl ether (NPOE), dioctyl phenylphosphonate (DOPP) and bis(2-ethylhexyl)adipate (EHA). The sensors display a fast, stable and near-Nernstian response over a relative wide ADQ concentration range (3.2 x 10(-6) to 2.0 x 10(-2) M), with slopes comprised between 28.5 and 31.4 mV dec(-1) in a pH range comprised between pH 3.7 and 5.5. The assay of amodiaquine hydrochloride in pharmaceutical dosage forms using one of the proposed sensors gave average recoveries of 104.3 and 99.9 with R.S.D. of 0.3 and 0.6% for tablets (Malaritab) and a reconstituted powder containing ADQ.2HCl, respectively. The sensor was also used for dissolution profile studies of two drug formulations. The sensor proved to have a good selectivity for ADQ.2HCl over some inorganic and organic compounds, however, berberine chloride interfered significantly. The results were validated by comparison with a spectrophotometric assay according to the USP pharmacopoeia.

  19. Nickel foam/polyaniline-based carbon/palladium composite electrodes for hydrogen storage

    International Nuclear Information System (INIS)

    Skowronski, Jan M.; Urbaniak, Jan

    2008-01-01

    The sandwich-like nickel/palladium/carbon electrodes exhibiting ability to absorb hydrogen in alkaline solution are presented. Electrodes were prepared by successive deposition of palladium and polyaniline layers on nickel foam substrate followed by heat treatment to give Ni/Pd/C electrode. It was shown that thermal conversion of polymer into carbon layer and subsequent thermal activation of carbon component bring about the modification of the mechanism of reversible hydrogen sorption. It was proven that carbon layer, interacting with Pd catalyst, plays a considerable role in the process of hydrogen storage. In the other series of experiments, Pd particles were dispersed electrochemically on carbon coating leading to Ni/C/Pd system. The adding of the next carbon layer resulted in Ni/C/Pd/C electrodes. Electrochemical properties of the electrodes depend on both the sequence of Pd and C layers and the preparation/activation of carbon coating. Electrochemical behavior of sandwich-like electrodes in the reaction of hydrogen sorption/desorption was characterized in 6 M KOH using the cyclic voltammetry method and the results obtained were compared to those for Ni/Pd electrode. The anodic desorption of hydrogen from electrodes free and containing carbon layer was considered after the potentiodynamic as well as potentiostatic sorption of hydrogen. The influence of the sorption potential and the time of rest of electrodes at a cut-off circuit on the kinetics of hydrogen recovery were examined. The results obtained for Ni/Pd/C electrodes indicate that the displacement of hydrogen between C and Pd phase takes place during the rest at a cut-off circuit. Electrodes containing carbon layer require longer time for hydrogen electrosorption. On the other hand, the presence of carbon layer in electrodes is advantageous because a considerable longer retention of hydrogen is possible, as compared to Pd/Ni electrode. Hydrogen stored in sandwich-like electrodes can instantly be

  20. Data on treatment of sewage wastewater by electrocoagulation using punched aluminum electrode and characterization of generated sludge

    Directory of Open Access Journals (Sweden)

    Vinita Khandegar

    2018-06-01

    Full Text Available The electrocoagulation setup must be optimized in order to design an economically feasible process. Therefore, in this work, the effect of the punched aluminum electrode on the performance of the electrocoagulation (EC has been investigated. A series of experiments were performed for treatment of sewage wastewater using plane electrode and compare with punched electrodes. Effect of contact time, voltage, electrode spacing and stirring speed has been optimized for removal of Biochemical oxygen demand (BOD and Total dissolved solids (TDS. It was observed that the performance of electrocoagulation process increased using punched electrode. Also, the less operating cost noticed in punched electrode as compared to a plane electrode for (70–80% removal of BOD and TDS. These data would be useful in designing of an EC reactor to obtain high removal efficiency at low energy consumption. Keywords: Electrocoagulation, Sewage wastewater, Aluminum, Plane, Punched electrode

  1. Hippocampal morphology mediates biased memories of chronic pain

    Science.gov (United States)

    Berger, Sara E.; Vachon-Presseau, Étienne; Abdullah, Taha B.; Baria, Alex T.; Schnitzer, Thomas J.; Apkarian, A. Vania

    2018-01-01

    Experiences and memories are often mismatched. While multiple studies have investigated psychological underpinnings of recall error with respect to emotional events, the neurobiological mechanisms underlying the divergence between experiences and memories remain relatively unexplored in the domain of chronic pain. Here we examined the discrepancy between experienced chronic low back pain (CBP) intensity (twice daily ratings) and remembered pain intensity (n = 48 subjects) relative to psychometric properties, hippocampus morphology, memory capabilities, and personality traits related to reward. 77% of CBP patients exaggerated remembered pain, which depended on their strongest experienced pain and their most recent mood rating. This bias persisted over nearly 1 year and was related to reward memory bias and loss aversion. Shape displacement of a specific region in the left posterior hippocampus mediated personality effects on pain memory bias, predicted pain memory bias in a validation CBP group (n = 21), and accounted for 55% of the variance of pain memory bias. In two independent groups (n = 20/group), morphology of this region was stable over time and unperturbed by the development of chronic pain. These results imply that a localized hippocampal circuit, and personality traits associated with reward processing, largely determine exaggeration of daily pain experiences in chronic pain patients. PMID:29080714

  2. Biased Brownian dynamics for rate constant calculation.

    OpenAIRE

    Zou, G; Skeel, R D; Subramaniam, S

    2000-01-01

    An enhanced sampling method-biased Brownian dynamics-is developed for the calculation of diffusion-limited biomolecular association reaction rates with high energy or entropy barriers. Biased Brownian dynamics introduces a biasing force in addition to the electrostatic force between the reactants, and it associates a probability weight with each trajectory. A simulation loses weight when movement is along the biasing force and gains weight when movement is against the biasing force. The sampl...

  3. Implied Dynamics Biases the Visual Perception of Velocity

    Science.gov (United States)

    La Scaleia, Barbara; Zago, Myrka; Moscatelli, Alessandro; Lacquaniti, Francesco; Viviani, Paolo

    2014-01-01

    We expand the anecdotic report by Johansson that back-and-forth linear harmonic motions appear uniform. Six experiments explore the role of shape and spatial orientation of the trajectory of a point-light target in the perceptual judgment of uniform motion. In Experiment 1, the target oscillated back-and-forth along a circular arc around an invisible pivot. The imaginary segment from the pivot to the midpoint of the trajectory could be oriented vertically downward (consistent with an upright pendulum), horizontally leftward, or vertically upward (upside-down). In Experiments 2 to 5, the target moved uni-directionally. The effect of suppressing the alternation of movement directions was tested with curvilinear (Experiment 2 and 3) or rectilinear (Experiment 4 and 5) paths. Experiment 6 replicated the upright condition of Experiment 1, but participants were asked to hold the gaze on a fixation point. When some features of the trajectory evoked the motion of either a simple pendulum or a mass-spring system, observers identified as uniform the kinematic profiles close to harmonic motion. The bias towards harmonic motion was most consistent in the upright orientation of Experiment 1 and 6. The bias disappeared when the stimuli were incompatible with both pendulum and mass-spring models (Experiments 3 to 5). The results are compatible with the hypothesis that the perception of dynamic stimuli is biased by the laws of motion obeyed by natural events, so that only natural motions appear uniform. PMID:24667578

  4. Implied dynamics biases the visual perception of velocity.

    Directory of Open Access Journals (Sweden)

    Barbara La Scaleia

    Full Text Available We expand the anecdotic report by Johansson that back-and-forth linear harmonic motions appear uniform. Six experiments explore the role of shape and spatial orientation of the trajectory of a point-light target in the perceptual judgment of uniform motion. In Experiment 1, the target oscillated back-and-forth along a circular arc around an invisible pivot. The imaginary segment from the pivot to the midpoint of the trajectory could be oriented vertically downward (consistent with an upright pendulum, horizontally leftward, or vertically upward (upside-down. In Experiments 2 to 5, the target moved uni-directionally. The effect of suppressing the alternation of movement directions was tested with curvilinear (Experiment 2 and 3 or rectilinear (Experiment 4 and 5 paths. Experiment 6 replicated the upright condition of Experiment 1, but participants were asked to hold the gaze on a fixation point. When some features of the trajectory evoked the motion of either a simple pendulum or a mass-spring system, observers identified as uniform the kinematic profiles close to harmonic motion. The bias towards harmonic motion was most consistent in the upright orientation of Experiment 1 and 6. The bias disappeared when the stimuli were incompatible with both pendulum and mass-spring models (Experiments 3 to 5. The results are compatible with the hypothesis that the perception of dynamic stimuli is biased by the laws of motion obeyed by natural events, so that only natural motions appear uniform.

  5. Implied dynamics biases the visual perception of velocity.

    Science.gov (United States)

    La Scaleia, Barbara; Zago, Myrka; Moscatelli, Alessandro; Lacquaniti, Francesco; Viviani, Paolo

    2014-01-01

    We expand the anecdotic report by Johansson that back-and-forth linear harmonic motions appear uniform. Six experiments explore the role of shape and spatial orientation of the trajectory of a point-light target in the perceptual judgment of uniform motion. In Experiment 1, the target oscillated back-and-forth along a circular arc around an invisible pivot. The imaginary segment from the pivot to the midpoint of the trajectory could be oriented vertically downward (consistent with an upright pendulum), horizontally leftward, or vertically upward (upside-down). In Experiments 2 to 5, the target moved uni-directionally. The effect of suppressing the alternation of movement directions was tested with curvilinear (Experiment 2 and 3) or rectilinear (Experiment 4 and 5) paths. Experiment 6 replicated the upright condition of Experiment 1, but participants were asked to hold the gaze on a fixation point. When some features of the trajectory evoked the motion of either a simple pendulum or a mass-spring system, observers identified as uniform the kinematic profiles close to harmonic motion. The bias towards harmonic motion was most consistent in the upright orientation of Experiment 1 and 6. The bias disappeared when the stimuli were incompatible with both pendulum and mass-spring models (Experiments 3 to 5). The results are compatible with the hypothesis that the perception of dynamic stimuli is biased by the laws of motion obeyed by natural events, so that only natural motions appear uniform.

  6. Exploring Attribution Theory and Bias

    Science.gov (United States)

    Robinson, Jessica A.

    2017-01-01

    Courses: This activity can be used in a wide range of classes, including interpersonal communication, introduction to communication, and small group communication. Objectives: After completing this activity, students should be able to: (1) define attribution theory, personality attribution, situational attribution, and attribution bias; (2)…

  7. Ratio Bias and Policy Preferences

    DEFF Research Database (Denmark)

    Pedersen, Rasmus Tue

    2016-01-01

    Numbers permeate modern political communication. While current scholarship on framing effects has focused on the persuasive effects of words and arguments, this article shows that framing of numbers can also substantially affect policy preferences. Such effects are caused by ratio bias, which...

  8. Bias in Peripheral Depression Biomarkers

    DEFF Research Database (Denmark)

    Carvalho, André F; Köhler, Cristiano A; Brunoni, André R

    2016-01-01

    BACKGROUND: To aid in the differentiation of individuals with major depressive disorder (MDD) from healthy controls, numerous peripheral biomarkers have been proposed. To date, no comprehensive evaluation of the existence of bias favoring the publication of significant results or inflating effect...

  9. Minimum Bias Trigger in ATLAS

    International Nuclear Information System (INIS)

    Kwee, Regina

    2010-01-01

    Since the restart of the LHC in November 2009, ATLAS has collected inelastic pp collisions to perform first measurements on charged particle densities. These measurements will help to constrain various models describing phenomenologically soft parton interactions. Understanding the trigger efficiencies for different event types are therefore crucial to minimize any possible bias in the event selection. ATLAS uses two main minimum bias triggers, featuring complementary detector components and trigger levels. While a hardware based first trigger level situated in the forward regions with 2.2 < |η| < 3.8 has been proven to select pp-collisions very efficiently, the Inner Detector based minimum bias trigger uses a random seed on filled bunches and central tracking detectors for the event selection. Both triggers were essential for the analysis of kinematic spectra of charged particles. Their performance and trigger efficiency measurements as well as studies on possible bias sources will be presented. We also highlight the advantage of these triggers for particle correlation analyses. (author)

  10. Gender bias in teaching evaluations

    NARCIS (Netherlands)

    Mengel, Friederike; Sauermann, Jan; Zölitz, Ulf Zoelitz

    2017-01-01

    This paper provides new evidence on gender bias in teaching evaluations. We exploit a quasi-experimental dataset of 19,952 student evaluations of university faculty in a context where students are randomly allocated to female or male instructors. Despite the fact that neither students’ grades nor

  11. Attentional Bias in Math Anxiety

    Directory of Open Access Journals (Sweden)

    Orly eRubinsten

    2015-10-01

    Full Text Available Cognitive theory from the field of general anxiety suggests that the tendency to display attentional bias toward negative information results in anxiety. Accordingly, the current study aims to investigate whether attentional bias is involved in math anxiety as well (i.e., a persistent negative reaction to math. Twenty seven participants (14 with high levels of math anxiety and 13 with low levels of math anxiety were presented with a novel computerized numerical version of the well established dot probe task. One of 6 types of prime stimuli, either math related or typically neutral, were presented on one side of a computer screen. The prime was preceded by a probe (either one or two asterisks that appeared in either the prime or the opposite location. Participants had to discriminate probe identity (one or two asterisks. Math anxious individuals reacted faster when the probe was at the location of the numerical related stimuli. This suggests the existence of attentional bias in math anxiety. That is, for math anxious individuals, the cognitive system selectively favored the processing of emotionally negative information (i.e., math related words. These findings suggest that attentional bias is linked to unduly intense math anxiety symptoms.

  12. Attentional bias in math anxiety.

    Science.gov (United States)

    Rubinsten, Orly; Eidlin, Hili; Wohl, Hadas; Akibli, Orly

    2015-01-01

    Cognitive theory from the field of general anxiety suggests that the tendency to display attentional bias toward negative information results in anxiety. Accordingly, the current study aims to investigate whether attentional bias is involved in math anxiety (MA) as well (i.e., a persistent negative reaction to math). Twenty seven participants (14 with high levels of MA and 13 with low levels of MA) were presented with a novel computerized numerical version of the well established dot probe task. One of six types of prime stimuli, either math related or typically neutral, was presented on one side of a computer screen. The prime was preceded by a probe (either one or two asterisks) that appeared in either the prime or the opposite location. Participants had to discriminate probe identity (one or two asterisks). Math anxious individuals reacted faster when the probe was at the location of the numerical related stimuli. This suggests the existence of attentional bias in MA. That is, for math anxious individuals, the cognitive system selectively favored the processing of emotionally negative information (i.e., math related words). These findings suggest that attentional bias is linked to unduly intense MA symptoms.

  13. Perception bias in route choice

    NARCIS (Netherlands)

    Vreeswijk, Jacob Dirk; Thomas, Tom; van Berkum, Eric C.; van Arem, Bart

    2014-01-01

    Travel time is probably one of the most studied attributes in route choice. Recently, perception of travel time received more attention as several studies have shown its importance in explaining route choice behavior. In particular, travel time estimates by travelers appear to be biased against

  14. Voltammetry at micro-mesh electrodes

    Directory of Open Access Journals (Sweden)

    Wadhawan Jay D.

    2003-01-01

    Full Text Available The voltammetry at three micro-mesh electrodes is explored. It is found that at sufficiently short experimental durations, the micro-mesh working electrode first behaves as an ensemble of microband electrodes, then follows the behaviour anticipated for an array of diffusion-independent micro-ring electrodes of the same perimeter as individual grid-squares within the mesh. During prolonged electrolysis, the micro-mesh electrode follows that behaviour anticipated theoretically for a cubically-packed partially-blocked electrode. Application of the micro-mesh electrode for the electrochemical determination of carbon dioxide in DMSO electrolyte solutions is further illustrated.

  15. The kinetics of porous insertion electrodes

    Energy Technology Data Exchange (ETDEWEB)

    Atlung, S; West, K [British Columbia Univ., Vancouver (Canada)

    1989-05-01

    The principles of porous electrodes are discussed as well as the discharge of the insertion compound, the working potential, transport in the electrolyte, the time dependence of the electrolyte concentration, and modeling of the porous electrode. The simulation of a TiS2 porous electrode and the composite insertion electrode are considered as well. The influence of electrode thickness and porosity in a typical porous TiS2 electrode is revealed. It is shown that the use of insertion compounds as battery electrodes is limited by the requirement that the inserted ion must be distributed in the interior of the insertion compound particle. 15 refs.

  16. Stimulation and recording electrodes for neural prostheses

    CERN Document Server

    Pour Aryan, Naser; Rothermel, Albrecht

    2015-01-01

    This book provides readers with basic principles of the electrochemistry of the electrodes used in modern, implantable neural prostheses. The authors discuss the boundaries and conditions in which the electrodes continue to function properly for long time spans, which are required when designing neural stimulator devices for long-term in vivo applications. Two kinds of electrode materials, titanium nitride and iridium are discussed extensively, both qualitatively and quantitatively. The influence of the counter electrode on the safety margins and electrode lifetime in a two electrode system is explained. Electrode modeling is handled in a final chapter.

  17. Apparatus bias and place conditioning with ethanol in mice.

    Science.gov (United States)

    Cunningham, Christopher L; Ferree, Nikole K; Howard, MacKenzie A

    2003-12-01

    Although the distinction between "biased" and "unbiased" is generally recognized as an important methodological issue in place conditioning, previous studies have not adequately addressed the distinction between a biased/unbiased apparatus and a biased/unbiased stimulus assignment procedure. Moreover, a review of the recent literature indicates that many reports (70% of 76 papers published in 2001) fail to provide adequate information about apparatus bias. This issue is important because the mechanisms underlying a drug's effect in the place-conditioning procedure may differ depending on whether the apparatus is biased or unbiased. The present studies were designed to assess the impact of apparatus bias and stimulus assignment procedure on ethanol-induced place conditioning in mice (DBA/2 J). A secondary goal was to compare various dependent variables commonly used to index conditioned place preference. Apparatus bias was manipulated by varying the combination of tactile (floor) cues available during preference tests. Experiment 1 used an unbiased apparatus in which the stimulus alternatives were equally preferred during a pre-test as indicated by the group average. Experiment 2 used a biased apparatus in which one of the stimuli was strongly preferred by most mice (mean % time on cue = 67%) during the pre-test. In both studies, the stimulus paired with drug (CS+) was assigned randomly (i.e., an "unbiased" stimulus assignment procedure). Experimental mice received four pairings of CS+ with ethanol (2 g/kg, i.p.) and four pairings of the alternative stimulus (CS-) with saline; control mice received saline on both types of trial. Each experiment concluded with a 60-min choice test. With the unbiased apparatus (experiment 1), significant place conditioning was obtained regardless of whether drug was paired with the subject's initially preferred or non-preferred stimulus. However, with the biased apparatus (experiment 2), place conditioning was apparent only when

  18. A split-cavity design for the incorporation of a DC bias in a 3D microwave cavity

    NARCIS (Netherlands)

    Cohen, M.A.; Yuan, M.; de Jong, B.W.A.; Beukers, Ewout; Bosman, S.J.; Steele, G.A.

    2017-01-01

    We report on a technique for applying a DC bias in a 3D microwave cavity. We achieve this by isolating the two halves of the cavity with a dielectric and directly using them as DC electrodes. As a proof of concept, we embed a variable capacitance diode in the cavity and tune the resonant

  19. Extraction electrode geometry for a calutron

    International Nuclear Information System (INIS)

    Veach, A.M.; Bell, W.A. Jr.

    1975-01-01

    This patent relates to an improved geometry for the extraction electrode and the ground electrode utilized in the operation of a calutron. The improved electrodes are constructed in a partial-picture-frame fashion with the slits of both electrodes formed by two tungsten elongated rods. Additional parallel spaced-apart rods in each electrode are used to establish equipotential surfaces over the rest of the front of the ion source

  20. Orientation- and position-controlled alignment of asymmetric silicon microrod on a substrate with asymmetric electrodes

    Science.gov (United States)

    Shibata, Akihide; Watanabe, Keiji; Sato, Takuya; Kotaki, Hiroshi; Schuele, Paul J.; Crowder, Mark A.; Zhan, Changqing; Hartzell, John W.; Nakatani, Ryoichi

    2014-03-01

    In this paper, we demonstrate the orientation-controlled alignment of asymmetric Si microrods on a glass substrate with an asymmetric pair of electrodes. The Si microrods have the shape of a paddle with a blade and a shaft part, and the pair of electrodes consists of a narrow electrode and a wide electrode. By applying AC bias to the electrodes, the Si microrods suspended in a fluid align in such a way to settle across the electrode pair, and over 80% of the aligned Si microrods have an orientation with the blade and the shaft of the paddle on the wide and the narrow electrodes, respectively. When Si microrods have a shell of dielectric film and its thickness on the top face is thicker than that on the bottom face, 97.8% of the Si microrods are aligned with the top face facing upwards. This technique is useful for orientation-controlled alignment of nano- and microsized devices that have polarity or a distinction between the top and bottom faces.

  1. Effects of Electrode Distances on Geometric Structure and Electronic Transport Properties of Molecular 4,4'-Bipyridine Junction

    International Nuclear Information System (INIS)

    Li Zongliang; Zou Bin; Wang Chuankui; Luo Yi

    2006-01-01

    Influences of electrode distances on geometric structure of molecule and on electronic transport properties of molecular junctions have been investigated by means of a generalized quantum chemical approach based on the elastic scattering Green's function method. Numerical results show that, for organic molecule 4,4'-bipyridine, the geometric structure of the molecule especially the dihedral angle between the two pyridine rings is sensitive to the distances between the two electrodes. The currents of the molecular junction are taken nonlinearly increase with the increase of the bias. Shortening the distance of the metallic electrodes will result in stronger coupling and larger conductance

  2. A surface-electrode quadrupole guide for electrons

    Energy Technology Data Exchange (ETDEWEB)

    Hoffrogge, Johannes Philipp

    2012-12-19

    This thesis reports on the design and first experimental realization of a surface-electrode quadrupole guide for free electrons. The guide is based on a miniaturized, planar electrode layout and is driven at microwave frequencies. It confines electrons in the near-field of the microwave excitation, where strong electric field gradients can be generated without resorting to resonating structures or exceptionally high drive powers. The use of chip-based electrode geometries allows the realization of versatile, microstructured potentials with the perspective of novel quantum experiments with guided electrons. I present the design, construction and operation of an experiment that demonstrates electron confinement in a planar quadrupole guide for the first time. To this end, electrons with kinetic energies from one to ten electron-volts are guided along a curved electrode geometry. The stability of electron guiding as a function of drive parameters and electron energy has been studied. A comparison with numerical particle tracking simulations yields good qualitative agreement and provides a deeper understanding of the electron dynamics in the guiding potential. Furthermore, this thesis gives a detailed description of the design of the surface-electrode layout. This includes the development of an optimized coupling structure to inject electrons into the guide with minimum transverse excitation. I also discuss the extension of the current setup to longitudinal guide dimensions that are comparable to or larger than the wavelength of the drive signal. This is possible with a modified electrode layout featuring elevated signal conductors. Electron guiding in the field of a planar, microfabricated electrode layout allows the generation of versatile and finely structured guiding potentials. One example would be the realization of junctions that split and recombine a guided electron beam. Furthermore, it should be possible to prepare electrons in low-lying quantum mechanical

  3. A surface-electrode quadrupole guide for electrons

    International Nuclear Information System (INIS)

    Hoffrogge, Johannes Philipp

    2012-01-01

    This thesis reports on the design and first experimental realization of a surface-electrode quadrupole guide for free electrons. The guide is based on a miniaturized, planar electrode layout and is driven at microwave frequencies. It confines electrons in the near-field of the microwave excitation, where strong electric field gradients can be generated without resorting to resonating structures or exceptionally high drive powers. The use of chip-based electrode geometries allows the realization of versatile, microstructured potentials with the perspective of novel quantum experiments with guided electrons. I present the design, construction and operation of an experiment that demonstrates electron confinement in a planar quadrupole guide for the first time. To this end, electrons with kinetic energies from one to ten electron-volts are guided along a curved electrode geometry. The stability of electron guiding as a function of drive parameters and electron energy has been studied. A comparison with numerical particle tracking simulations yields good qualitative agreement and provides a deeper understanding of the electron dynamics in the guiding potential. Furthermore, this thesis gives a detailed description of the design of the surface-electrode layout. This includes the development of an optimized coupling structure to inject electrons into the guide with minimum transverse excitation. I also discuss the extension of the current setup to longitudinal guide dimensions that are comparable to or larger than the wavelength of the drive signal. This is possible with a modified electrode layout featuring elevated signal conductors. Electron guiding in the field of a planar, microfabricated electrode layout allows the generation of versatile and finely structured guiding potentials. One example would be the realization of junctions that split and recombine a guided electron beam. Furthermore, it should be possible to prepare electrons in low-lying quantum mechanical

  4. A new method for mapping perceptual biases across visual space.

    Science.gov (United States)

    Finlayson, Nonie J; Papageorgiou, Andriani; Schwarzkopf, D Samuel

    2017-08-01

    How we perceive the environment is not stable and seamless. Recent studies found that how a person qualitatively experiences even simple visual stimuli varies dramatically across different locations in the visual field. Here we use a method we developed recently that we call multiple alternatives perceptual search (MAPS) for efficiently mapping such perceptual biases across several locations. This procedure reliably quantifies the spatial pattern of perceptual biases and also of uncertainty and choice. We show that these measurements are strongly correlated with those from traditional psychophysical methods and that exogenous attention can skew biases without affecting overall task performance. Taken together, MAPS is an efficient method to measure how an individual's perceptual experience varies across space.

  5. 3D finite element modeling of epiretinal stimulation: Impact of prosthetic electrode size and distance from the retina.

    Science.gov (United States)

    Sui, Xiaohong; Huang, Yu; Feng, Fuchen; Huang, Chenhui; Chan, Leanne Lai Hang; Wang, Guoxing

    2015-05-01

    A novel 3-dimensional (3D) finite element model was established to systematically investigate the impact of the diameter (Φ) of disc electrodes and the electrode-to-retina distance on the effectiveness of stimulation. The 3D finite element model was established based on a disc platinum stimulating electrode and a 6-layered retinal structure. The ground electrode was placed in the extraocular space in direct attachment with sclera and treated as a distant return electrode. An established criterion of electric-field strength of 1000 Vm-1 was adopted as the activation threshold for RGCs. The threshold current (TC) increased linearly with increasing Φ and electrode-to-retina distance and remained almost unchanged with further increases in diameter. However, the threshold charge density (TCD) increased dramatically with decreasing electrode diameter. TCD exceeded the electrode safety limit for an electrode diameter of 50 µm at an electrode-to-retina distance of 50 to 200 μm. The electric field distributions illustrated that smaller electrode diameters and shorter electrode-to-retina distances were preferred due to more localized excitation of RGC area under stimulation of different threshold currents in terms of varied electrode size and electrode-to-retina distances. Under the condition of same-amplitude current stimulation, a large electrode exhibited an improved potential spatial selectivity at large electrode-to-retina distances. Modeling results were consistent with those reported in animal electrophysiological experiments and clinical trials, validating the 3D finite element model of epiretinal stimulation. The computational model proved to be useful in optimizing the design of an epiretinal stimulating electrode for prosthesis.

  6. A method for additive bias correction in cross-cultural surveys

    DEFF Research Database (Denmark)

    Scholderer, Joachim; Grunert, Klaus G.; Brunsø, Karen

    2001-01-01

    additive bias from cross-cultural data. The procedure involves four steps: (1) embed a potentially biased item in a factor-analytic measurement model, (2) test for the existence of additive bias between populations, (3) use the factor-analytic model to estimate the magnitude of the bias, and (4) replace......Measurement bias in cross-cultural surveys can seriously threaten the validity of hypothesis tests. Direct comparisons of means depend on the assumption that differences in observed variables reflect differences in the underlying constructs, and not an additive bias that may be caused by cultural...... differences in the understanding of item wording or response category labels. However, experience suggests that additive bias can be found more often than not. Based on the concept of partial measurement invariance (Byrne, Shavelson and Muthén, 1989), the present paper develops a procedure for eliminating...

  7. A procedure for eliminating additive bias from cross-cultural survey data

    DEFF Research Database (Denmark)

    Scholderer, Joachim; Grunert, Klaus G.; Brunsø, Karen

    2005-01-01

    additive bias from cross-cultural data. The procedure involves four steps: (1) embed a potentially biased item in a factor-analytic measurement model, (2) test for the existence of additive bias between populations, (3) use the factor-analytic model to estimate the magnitude of the bias, and (4) replace......Measurement bias in cross-cultural surveys can seriously threaten the validity of hypothesis tests. Direct comparisons of means depend on the assumption that differences in observed variables reflect differences in the underlying constructs, and not an additive bias that may be caused by cultural...... differences in the understanding of item wording or response category labels. However, experience suggests that additive bias can be found more often than not. Based on the concept of partial measurement invariance (Byrne, Shavelson and Muthén 1989), the present paper develops a procedure for eliminating...

  8. Time-dependent ion selectivity in capacitive charging of porous electrodes

    NARCIS (Netherlands)

    Zhao, R.; Soestbergen, M.; Rijnaarts, H.H.M.; Wal, van der A.F.; Bazant, M.Z.; Biesheuvel, P.M.

    2012-01-01

    In a combined experimental and theoretical study, we show that capacitive charging of porous electrodes in multicomponent electrolytes may lead to the phenomenon of time-dependent ion selectivity of the electrical double layers (EDLs) in the electrodes. This effect is found in experiments on

  9. Modifications of plasma edge electric field and confinement properties by limiter biasing on the KT-5C tokamak

    International Nuclear Information System (INIS)

    Hui Gao; Kan Zhai; Yizhi Wen; Shude Wan; Guiding Wang; Changxun Yu

    1995-01-01

    Experiments using a biased multiblock limiter in the KT-5C tokamak show that positive biasing is more effective than negative biasing in modifying the edge electric field, suppressing fluctuations and improving plasma confinement. The biasing effect varies with the limiter area, the toroidal magnetic field and the biasing voltage. By positive biasing, the edge profiles of the plasma potential, the electron temperature and the density become steeper, resulting in a reduced edge particle flux, an increased global particle confinement time and lower fluctuation levels of the edge plasma. (author)

  10. Editorial Bias in Crowd-Sourced Political Information.

    Directory of Open Access Journals (Sweden)

    Joshua L Kalla

    Full Text Available The Internet has dramatically expanded citizens' access to and ability to engage with political information. On many websites, any user can contribute and edit "crowd-sourced" information about important political figures. One of the most prominent examples of crowd-sourced information on the Internet is Wikipedia, a free and open encyclopedia created and edited entirely by users, and one of the world's most accessed websites. While previous studies of crowd-sourced information platforms have found them to be accurate, few have considered biases in what kinds of information are included. We report the results of four randomized field experiments that sought to explore what biases exist in the political articles of this collaborative website. By randomly assigning factually true but either positive or negative and cited or uncited information to the Wikipedia pages of U.S. senators, we uncover substantial evidence of an editorial bias toward positivity on Wikipedia: Negative facts are 36% more likely to be removed by Wikipedia editors than positive facts within 12 hours and 29% more likely within 3 days. Although citations substantially increase an edit's survival time, the editorial bias toward positivity is not eliminated by inclusion of a citation. We replicate this study on the Wikipedia pages of deceased as well as recently retired but living senators and find no evidence of an editorial bias in either. Our results demonstrate that crowd-sourced information is subject to an editorial bias that favors the politically active.

  11. Editorial Bias in Crowd-Sourced Political Information.

    Science.gov (United States)

    Kalla, Joshua L; Aronow, Peter M

    2015-01-01

    The Internet has dramatically expanded citizens' access to and ability to engage with political information. On many websites, any user can contribute and edit "crowd-sourced" information about important political figures. One of the most prominent examples of crowd-sourced information on the Internet is Wikipedia, a free and open encyclopedia created and edited entirely by users, and one of the world's most accessed websites. While previous studies of crowd-sourced information platforms have found them to be accurate, few have considered biases in what kinds of information are included. We report the results of four randomized field experiments that sought to explore what biases exist in the political articles of this collaborative website. By randomly assigning factually true but either positive or negative and cited or uncited information to the Wikipedia pages of U.S. senators, we uncover substantial evidence of an editorial bias toward positivity on Wikipedia: Negative facts are 36% more likely to be removed by Wikipedia editors than positive facts within 12 hours and 29% more likely within 3 days. Although citations substantially increase an edit's survival time, the editorial bias toward positivity is not eliminated by inclusion of a citation. We replicate this study on the Wikipedia pages of deceased as well as recently retired but living senators and find no evidence of an editorial bias in either. Our results demonstrate that crowd-sourced information is subject to an editorial bias that favors the politically active.

  12. Development of a Compact Wireless Laplacian Electrode Module for Electromyograms and Its Human Interface Applications

    Directory of Open Access Journals (Sweden)

    Akira Ichikawa

    2013-02-01

    Full Text Available In this study, we developed a compact wireless Laplacian electrode module for electromyograms (EMGs. One of the advantages of the Laplacian electrode configuration is that EMGs obtained with it are expected to be sensitive to the firing of the muscle directly beneath the measurement site. The performance of the developed electrode module was investigated in two human interface applications: character-input interface and detection of finger movement during finger Braille typing. In the former application, the electrode module was combined with an EMG-mouse click converter circuit. In the latter, four electrode modules were used for detection of finger movements during finger Braille typing. Investigation on the character-input interface indicated that characters could be input stably by contraction of (a the masseter, (b trapezius, (c anterior tibialis and (d flexor carpi ulnaris muscles. This wide applicability is desirable when the interface is applied to persons with physical disabilities because the disability differs one to another. The investigation also demonstrated that the electrode module can work properly without any skin preparation. Finger movement detection experiments showed that each finger movement was more clearly detectable when comparing to EMGs recorded with conventional electrodes, suggesting that the Laplacian electrode module is more suitable for detecting the timing of finger movement during typing. This could be because the Laplacian configuration enables us to record EMGs just beneath the electrode. These results demonstrate the advantages of the Laplacian electrode module.

  13. Testing electrode suitability for field stimulation of high-threshold biological preparations

    Directory of Open Access Journals (Sweden)

    Hugo Fernando Maia Milan

    Full Text Available IntroductionA problem posed by electrical field (E stimulation of biological preparations with high excitation threshold is that the E intensity required for excitation is likely to induce water electrolysis at the electrode surface, which can alter the extracellular medium and cause deleterious effects on the cells. In this study, different electrode materials and geometries were tested aiming at identifying electrode configurations that could transduce the E intensity required for exciting ventricular cardiomyocytes isolated from neonatal rats (threshold E ~30 V/cm without causing water electrolysis.MethodsWire and plate electrodes made of platinum, stainless steel and nickel/chrome alloy were used. The effect of blasting the electrode surface with sand and NaHCO3 solution was also tested. Electrodes were inserted into a cell perfusion chamber containing the saline solution routinely used for physiological experiments. During E application for 5 min, the electrode surface and its surroundings were examined at high magnification for the presence of microbubbles, which indicates the occurrence of water electrolysis. The greatest E intensity applied that failed to generate microbubbles (En was estimated.ResultsWhile nickel/chrome and stainless steel electrodes resulted in low En values, the best performance was observed for sandblasted platinum wire (2 mm diameter and plate (25 mm x 5 mm; 0.1 mm thickness electrodes, for which Enwas ≥40 V/cm.ConclusionThese electrode configurations are suitable for effective and safe stimulation of isolated neonatal cardiomyocytes.

  14. Evaluation of bias associated with high-multiplex, target-specific pre-amplification

    Directory of Open Access Journals (Sweden)

    Steven T. Okino

    2016-01-01

    Full Text Available We developed a novel PCR-based pre-amplification (PreAmp technology that can increase the abundance of over 350 target genes one million-fold. To assess potential bias introduced by PreAmp we utilized ERCC RNA reference standards, a model system that quantifies measurement error in RNA analysis. We assessed three types of bias: amplification bias, dynamic range bias and fold-change bias. We show that our PreAmp workflow introduces only minimal amplification and fold-change bias under stringent conditions. We do detect dynamic range bias if a target gene is highly abundant and PreAmp occurred for 16 or more PCR cycles; however, this type of bias is easily correctable. To assess PreAmp bias in a gene expression profiling experiment, we analyzed a panel of genes that are regulated during differentiation using the NTera2 stem cell model system. We find that results generated using PreAmp are similar to results obtained using standard qPCR (without the pre-amplification step. Importantly, PreAmp maintains patterns of gene expression changes across samples; the same biological insights would be derived from a PreAmp experiment as with a standard gene expression profiling experiment. We conclude that our PreAmp technology can facilitate analysis of extremely limited samples in gene expression quantification experiments.

  15. Reducing Prejudice With Labels: Shared Group Memberships Attenuate Implicit Bias and Expand Implicit Group Boundaries.

    Science.gov (United States)

    Scroggins, W Anthony; Mackie, Diane M; Allen, Thomas J; Sherman, Jeffrey W

    2016-02-01

    In three experiments, we used a novel Implicit Association Test procedure to investigate the impact of group memberships on implicit bias and implicit group boundaries. Results from Experiment 1 indicated that categorizing targets using a shared category reduced implicit bias by increasing the extent to which positivity was associated with Blacks. Results from Experiment 2 revealed that shared group membership, but not mere positivity of a group membership, was necessary to reduce implicit bias. Quadruple process model analyses indicated that changes in implicit bias caused by shared group membership are due to changes in the way that targets are evaluated, not to changes in the regulation of evaluative bias. Results from Experiment 3 showed that categorizing Black targets into shared group memberships expanded implicit group boundaries. © 2015 by the Society for Personality and Social Psychology, Inc.

  16. Study on Carbon Nano composite Counter electrode for Dye-Sensitized Solar Cells

    International Nuclear Information System (INIS)

    Chen, Y.; Zhang, H.; Lin, J.

    2012-01-01

    Carbon nano composite electrodes were prepared by adding carbon nano tubes (CNTs) into carbon black as counter electrodes of dye-sensitized solar cells (DSSCs). The morphology and structure of carbon nano composite electrodes were studied by scanning electron microscopy. The influence of CNTs on the electrochemical performance of carbon nano composite electrodes is investigated by cyclic voltammetry and electrochemical impedance spectroscopy. Carbon nano composite electrodes with CNTs exhibit a highly interconnected network structure with high electrical conductivity and good catalytic activity. The influence of different CNTs content in carbon nano composite electrodes on the open-circuit voltage, short-circuit current, and filling factor of DSSCs is also investigated. DSSCs with 10% CNTs content exhibit the best photovoltaic performance in our experiments.

  17. Sequential injection of domain walls into ferroelectrics at different bias voltages: Paving the way for “domain wall memristors”

    Energy Technology Data Exchange (ETDEWEB)

    Whyte, J. R.; McQuaid, R. G. P.; Einsle, J. F.; Gregg, J. M., E-mail: m.gregg@qub.ac.uk [Centre for Nanostructured Media (CNM), School of Maths and Physics, Queen' s University Belfast, University Road, Belfast BT7 1NN (United Kingdom); Ashcroft, C. M. [Centre for Nanostructured Media (CNM), School of Maths and Physics, Queen' s University Belfast, University Road, Belfast BT7 1NN (United Kingdom); Department of Physics, Cavendish Laboratory, J. J. Thomson Avenue, Cambridge CB3 0HE (United Kingdom); Canalias, C. [Department of Applied Physics, Royal Institute of Technology, Roslagstullsbacken 21, 10691 Stockholm (Sweden); Gruverman, A. [Department of Physics and Astronomy, University of Nebraska Lincoln, Nebraska 68588–0299 (United States)

    2014-08-14

    Simple meso-scale capacitor structures have been made by incorporating thin (∼300 nm) single crystal lamellae of KTiOPO{sub 4} (KTP) between two coplanar Pt electrodes. The influence that either patterned protrusions in the electrodes or focused ion beam milled holes in the KTP have on the nucleation of reverse domains during switching was mapped using piezoresponse force microscopy imaging. The objective was to assess whether or not variations in the magnitude of field enhancement at localised “hot-spots,” caused by such patterning, could be used to both control the exact locations and bias voltages at which nucleation events occurred. It was found that both the patterning of electrodes and the milling of various hole geometries into the KTP could allow controlled sequential injection of domain wall pairs at different bias voltages; this capability could have implications for the design and operation of domain wall electronic devices, such as memristors, in the future.

  18. Magnification bias as a novel probe for primordial magnetic fields

    International Nuclear Information System (INIS)

    Camera, S.; Fedeli, C.; Moscardini, L.

    2014-01-01

    In this paper we investigate magnetic fields generated in the early Universe. These fields are important candidates at explaining the origin of astrophysical magnetism observed in galaxies and galaxy clusters, whose genesis is still by and large unclear. Compared to the standard inflationary power spectrum, intermediate to small scales would experience further substantial matter clustering, were a cosmological magnetic field present prior to recombination. As a consequence, the bias and redshift distribution of galaxies would also be modified. Hitherto, primordial magnetic fields (PMFs) have been tested and constrained with a number of cosmological observables, e.g. the cosmic microwave background radiation, galaxy clustering and, more recently, weak gravitational lensing. Here, we explore the constraining potential of the density fluctuation bias induced by gravitational lensing magnification onto the galaxy-galaxy angular power spectrum. Such an effect is known as magnification bias. Compared to the usual galaxy clustering approach, magnification bias helps in lifting the pathological degeneracy present amongst power spectrum normalisation and galaxy bias. This is because magnification bias cross-correlates galaxy number density fluctuations of nearby objects with weak lensing distortions of high-redshift sources. Thus, it takes advantage of the gravitational deflection of light, which is insensitive to galaxy bias but powerful in constraining the density fluctuation amplitude. To scrutinise the potentiality of this method, we adopt a deep and wide-field spectroscopic galaxy survey. We show that magnification bias does contain important information on primordial magnetism, which will be useful in combination with galaxy clustering and shear. We find we shall be able to rule out at 95.4% CL amplitudes of PMFs larger than 5 × 10 −4 nG for values of the PMF power spectral index n B ∼ 0

  19. Giant rectification in graphene nanoflake molecular devices with asymmetric graphene nanoribbon electrodes

    International Nuclear Information System (INIS)

    Ji, Xiao-Li; Xie, Zhen; Zuo, Xi; Zhang, Guang-Ping; Li, Zong-Liang; Wang, Chuan-Kui

    2016-01-01

    By applying density functional theory based nonequilibrium Green's function method, we theoretically investigate the electron transport properties of a zigzag-edged trigonal graphene nanoflake (ZTGNF) sandwiched between two asymmetric zigzag graphene nanoribbon (zGNR) and armchair graphene nanoribbon (aGNR) electrodes with carbon atomic chains (CACs) as the anchoring groups. Significant rectifying effects have been observed for these molecular devices in low bias voltage regions. Interestingly, the rectifying performance of molecular devices can be optimized by changing the width of the aGNR electrode and the number of anchoring CACs. Especially, the molecular device displays giant rectification ratios up to the order of 10"4 when two CACs are used as the anchoring group between the ZTGNF and the right aGNR electrode. Further analysis indicates that the asymmetric shift of the perturbed molecular energy levels and the spatial parity of the electron wavefunctions in the electrodes around the Fermi level play key roles in determining the rectification performance. And the spatial distributions of tunneling electron wavefunctions under negative bias voltages can be modified to be very localized by changing the number of anchoring CACs, which is found to be the origin of the giant rectification ratios. - Highlights: • The rectification properties of triangular Graphene nanoflakes are investigated. • The rectifying performance can be optimized by changing the width of the right arm-chaired GNR electrode. • The rectifying performance can also be tuned by varying the number of anchoring carbon atomic chains.

  20. Electrode spanning with partial tripolar stimulation mode in cochlear implants.

    Science.gov (United States)

    Wu, Ching-Chih; Luo, Xin

    2014-12-01

    The perceptual effects of electrode spanning (i.e., the use of nonadjacent return electrodes) in partial tripolar (pTP) mode were tested on a main electrode EL8 in five cochlear implant (CI) users. Current focusing was controlled by σ (the ratio of current returned within the cochlea), and current steering was controlled by α (the ratio of current returned to the basal electrode). Experiment 1 tested whether asymmetric spanning with α = 0.5 can create additional channels around standard pTP stimuli. It was found that in general, apical spanning (i.e., returning current to EL6 rather than EL7) elicited a pitch between those of standard pTP stimuli on main electrodes EL8 and EL9, while basal spanning (i.e., returning current to EL10 rather than EL9) elicited a pitch between those of standard pTP stimuli on main electrodes EL7 and EL8. The pitch increase caused by apical spanning was more salient than the pitch decrease caused by basal spanning. To replace the standard pTP channel on the main electrode EL8 when EL7 or EL9 is defective, experiment 2 tested asymmetrically spanned pTP stimuli with various α, and experiment 3 tested symmetrically spanned pTP stimuli with various σ. The results showed that pitch increased with decreasing α in asymmetric spanning, or with increasing σ in symmetric spanning. Apical spanning with α around 0.69 and basal spanning with α around 0.38 may both elicit a similar pitch as the standard pTP stimulus. With the same σ, the symmetrically spanned pTP stimulus was higher in pitch than the standard pTP stimulus. A smaller σ was thus required for symmetric spanning to match the pitch of the standard pTP stimulus. In summary, electrode spanning is an effective field-shaping technique that is useful for adding spectral channels and handling defective electrodes with CIs.

  1. Hybrid biasing approaches for global variance reduction

    International Nuclear Information System (INIS)

    Wu, Zeyun; Abdel-Khalik, Hany S.

    2013-01-01

    A new variant of Monte Carlo—deterministic (DT) hybrid variance reduction approach based on Gaussian process theory is presented for accelerating convergence of Monte Carlo simulation and compared with Forward-Weighted Consistent Adjoint Driven Importance Sampling (FW-CADIS) approach implemented in the SCALE package from Oak Ridge National Laboratory. The new approach, denoted the Gaussian process approach, treats the responses of interest as normally distributed random processes. The Gaussian process approach improves the selection of the weight windows of simulated particles by identifying a subspace that captures the dominant sources of statistical response variations. Like the FW-CADIS approach, the Gaussian process approach utilizes particle importance maps obtained from deterministic adjoint models to derive weight window biasing. In contrast to the FW-CADIS approach, the Gaussian process approach identifies the response correlations (via a covariance matrix) and employs them to reduce the computational overhead required for global variance reduction (GVR) purpose. The effective rank of the covariance matrix identifies the minimum number of uncorrelated pseudo responses, which are employed to bias simulated particles. Numerical experiments, serving as a proof of principle, are presented to compare the Gaussian process and FW-CADIS approaches in terms of the global reduction in standard deviation of the estimated responses. - Highlights: ► Hybrid Monte Carlo Deterministic Method based on Gaussian Process Model is introduced. ► Method employs deterministic model to calculate responses correlations. ► Method employs correlations to bias Monte Carlo transport. ► Method compared to FW-CADIS methodology in SCALE code. ► An order of magnitude speed up is achieved for a PWR core model.

  2. Exploring the electrodes alignment and mushrooming effects on ...

    Indian Academy of Sciences (India)

    effects on weld geometry of dissimilar steels during the spot welding ... purpose for the welding of steels and withstand for high thermal application on ... the electrode alignment during welding process plays a significant role on the formation of weld ... experiment using Ansys 14 (figure 3). .... Materials and Design 68–77.

  3. Simultaneous perceptual and response biases on sequential face attractiveness judgments

    Science.gov (United States)

    Pegors, Teresa K.; Mattar, Marcelo G.; Bryan, Peter B.; Epstein, Russell A.

    2015-01-01

    Face attractiveness is a social characteristic that we often use to make first-pass judgments about the people around us. However, these judgments are highly influenced by our surrounding social world, and researchers still understand little about the mechanisms underlying these influences. In a series of three experiments, we used a novel sequential rating paradigm that enabled us to measure biases on attractiveness judgments from the previous face and the previous rating. Our results revealed two simultaneous and opposing influences on face attractiveness judgments that arise from our past experience of faces: a response bias in which attractiveness ratings shift towards a previously given rating, and a stimulus bias in which attractiveness ratings shift away from the mean attractiveness of the previous face. Furthermore, we provide evidence that the contrastive stimulus bias (but not the assimilative response bias) is strengthened by increasing the duration of the previous stimulus, suggesting an underlying perceptual mechanism. These results demonstrate that judgments of face attractiveness are influenced by information from our evaluative and perceptual history and that these influences have measurable behavioral effects over the course of just a few seconds. PMID:25867223

  4. Biased lineup instructions and face identification from video images.

    Science.gov (United States)

    Thompson, W Burt; Johnson, Jaime

    2008-01-01

    Previous eyewitness memory research has shown that biased lineup instructions reduce identification accuracy, primarily by increasing false-positive identifications in target-absent lineups. Because some attempts at identification do not rely on a witness's memory of the perpetrator but instead involve matching photos to images on surveillance video, the authors investigated the effects of biased instructions on identification accuracy in a matching task. In Experiment 1, biased instructions did not affect the overall accuracy of participants who used video images as an identification aid, but nearly all correct decisions occurred with target-present photo spreads. Both biased and unbiased instructions resulted in high false-positive rates. In Experiment 2, which focused on video-photo matching accuracy with target-absent photo spreads, unbiased instructions led to more correct responses (i.e., fewer false positives). These findings suggest that investigators should not relax precautions against biased instructions when people attempt to match photos to an unfamiliar person recorded on video.

  5. On the Road to Cultural Bias. Media Corner.

    Science.gov (United States)

    Bigelow, Bill, Ed.

    1996-01-01

    Assesses the strengths and weaknesses of the interactive CD-ROM "The Oregon Trail." Maintains that, although the program offers a sympathetic portrayal of Native Americans, it is still rife with cultural bias. The simulation's structure accentuates the white male experience at the expense of others. (MJP)

  6. Taming astrophysical bias in direct dark matter searches

    NARCIS (Netherlands)

    Pato, M.; Strigari, L.E.; Trotta, R.; Bertone, G.

    2013-01-01

    We explore systematic biases in the identification of dark matter in future direct detection experiments and compare the reconstructed dark matter properties when assuming a self-consistent dark matter distribution function and the standard Maxwellian velocity distribution. We find that the

  7. Variable-bias coin tossing

    International Nuclear Information System (INIS)

    Colbeck, Roger; Kent, Adrian

    2006-01-01

    Alice is a charismatic quantum cryptographer who believes her parties are unmissable; Bob is a (relatively) glamorous string theorist who believes he is an indispensable guest. To prevent possibly traumatic collisions of self-perception and reality, their social code requires that decisions about invitation or acceptance be made via a cryptographically secure variable-bias coin toss (VBCT). This generates a shared random bit by the toss of a coin whose bias is secretly chosen, within a stipulated range, by one of the parties; the other party learns only the random bit. Thus one party can secretly influence the outcome, while both can save face by blaming any negative decisions on bad luck. We describe here some cryptographic VBCT protocols whose security is guaranteed by quantum theory and the impossibility of superluminal signaling, setting our results in the context of a general discussion of secure two-party computation. We also briefly discuss other cryptographic applications of VBCT

  8. Probability biases as Bayesian inference

    Directory of Open Access Journals (Sweden)

    Andre; C. R. Martins

    2006-11-01

    Full Text Available In this article, I will show how several observed biases in human probabilistic reasoning can be partially explained as good heuristics for making inferences in an environment where probabilities have uncertainties associated to them. Previous results show that the weight functions and the observed violations of coalescing and stochastic dominance can be understood from a Bayesian point of view. We will review those results and see that Bayesian methods should also be used as part of the explanation behind other known biases. That means that, although the observed errors are still errors under the be understood as adaptations to the solution of real life problems. Heuristics that allow fast evaluations and mimic a Bayesian inference would be an evolutionary advantage, since they would give us an efficient way of making decisions. %XX In that sense, it should be no surprise that humans reason with % probability as it has been observed.

  9. Variable-bias coin tossing

    Science.gov (United States)

    Colbeck, Roger; Kent, Adrian

    2006-03-01

    Alice is a charismatic quantum cryptographer who believes her parties are unmissable; Bob is a (relatively) glamorous string theorist who believes he is an indispensable guest. To prevent possibly traumatic collisions of self-perception and reality, their social code requires that decisions about invitation or acceptance be made via a cryptographically secure variable-bias coin toss (VBCT). This generates a shared random bit by the toss of a coin whose bias is secretly chosen, within a stipulated range, by one of the parties; the other party learns only the random bit. Thus one party can secretly influence the outcome, while both can save face by blaming any negative decisions on bad luck. We describe here some cryptographic VBCT protocols whose security is guaranteed by quantum theory and the impossibility of superluminal signaling, setting our results in the context of a general discussion of secure two-party computation. We also briefly discuss other cryptographic applications of VBCT.

  10. Robust high temperature oxygen sensor electrodes

    DEFF Research Database (Denmark)

    Lund, Anders

    Platinum is the most widely used material in high temperature oxygen sensor electrodes. However, platinum is expensive and the platinum electrode may, under certain conditions, suffer from poisoning, which is detrimental for an oxygen sensor. The objective of this thesis is to evaluate electrode...... materials as candidates for robust oxygen sensor electrodes. The present work focuses on characterising the electrochemical properties of a few electrode materials to understand which oxygen electrode processes are limiting for the response time of the sensor electrode. Three types of porous platinum......-Dansensor. The electrochemical properties of the electrodes were characterised by electrochemical impedance spectroscopy (EIS), and the structures were characterised by x-ray diffraction and electron microscopy. At an oxygen partial pressures of 0.2 bar, the response time of the sensor electrode was determined by oxygen...

  11. Girl child and gender bias.

    Science.gov (United States)

    Chowdhry, D P

    1995-01-01

    This article identifies gender bias against female children and youth in India. Gender bias is based on centuries-old religious beliefs and sayings from ancient times. Discrimination is reflected in denial or ignorance of female children's educational, health, nutrition, and recreational needs. Female infanticide and selective abortion of female fetuses are other forms of discrimination. The task of eliminating or reducing gender bias will involve legal, developmental, political, and administrative measures. Public awareness needs to be created. There is a need to reorient the education and health systems and to advocate for gender equality. The government of India set the following goals for the 1990s: to protect the survival of the girl child and practice safe motherhood; to develop the girl child in general; and to protect vulnerable girl children in different circumstances and in special groups. The Health Authorities should monitor the laws carefully to assure marriage after the minimum age, ban sex determination of the fetus, and monitor the health and nutrition of pre-school girls and nursing and pregnant mothers. Mothers need to be encouraged to breast feed, and to breast feed equally between genders. Every village and slum area needs a mini health center. Maternal mortality must decline. Primary health centers and hospitals need more women's wards. Education must be universally accessible. Enrollments should be increased by educating rural tribal and slum parents, reducing distances between home and school, making curriculum more relevant to girls, creating more female teachers, and providing facilities and incentives for meeting the needs of girl students. Supplementary income could be provided to families for sending girls to school. Recreational activities must be free of gender bias. Dowry, sati, and devdasi systems should be banned.

  12. Competition and Commercial Media Bias

    OpenAIRE

    Blasco, Andrea; Sobbrio, Francesco

    2011-01-01

    This paper reviews the empirical evidence on commercial media bias (i.e., advertisers influence over media accuracy) and then introduces a simple model to summarize the main elements of the theoretical literature. The analysis provides three main policy insights for media regulators: i) Media regulators should target their monitoring efforts towards news contents upon which advertisers are likely to share similar preferences; ii) In advertising industries characterized by high correlation in ...

  13. BEHAVIORAL BIASES IN TRADING SECURITIES

    Directory of Open Access Journals (Sweden)

    Turcan Ciprian Sebastian

    2010-12-01

    Full Text Available The main thesis of this paper represents the importance and the effects that human behavior has over capital markets. It is important to see the link between the asset valuation and investor sentiment that motivate to pay for an asset a certain prices over/below the intrinsic value. The main behavioral aspects discussed are emotional factors such as: fear of regret, overconfidence, perseverance, loss aversion ,heuristic biases, misinformation and thinking errors, herding and their consequences.

  14. Bias-dependent model of the electrical impedance of ionic polymer-metal composites.

    Science.gov (United States)

    Cha, Youngsu; Porfiri, Maurizio

    2013-02-01

    In this paper, we analyze the charge dynamics of ionic polymer-metal composites (IPMCs) in response to voltage inputs composed of a large dc bias and a small superimposed time-varying voltage. The IPMC chemoelectrical behavior is described through the modified Poisson-Nernst-Planck framework, in which steric effects are taken into consideration. The physics of charge build-up and mass transfer in the proximity of the high surface electrodes is modeled by schematizing the IPMC as the stacked sequence of five layers, in which the ionomeric membrane is separated from the metal electrodes by two composite layers. The method of matched asymptotic expansions is used to derive a semianalytical solution for the concentration of mobile counterions and the electric potential in the IPMC, which is, in turn, used to establish an equivalent circuit model for the IPMC electrical response. The circuit model consists of the series connection of a resistor and two complex elements, each constituted by the parallel connection of a capacitor and a Warburg impedance. The resistor is associated with ion transport in the ionomeric membrane and is independent of the dc bias. The capacitors and the Warburg impedance idealize charge build-up and mass transfer in the vicinity of the electrodes and their value is controlled by the dc bias. The proposed approach is validated against experimental results on in-house fabricated IPMCs and the accuracy of the equivalent circuit is assessed through comparison with finite element results.

  15. Significant biases affecting abundance determinations

    Science.gov (United States)

    Wesson, Roger

    2015-08-01

    I have developed two highly efficient codes to automate analyses of emission line nebulae. The tools place particular emphasis on the propagation of uncertainties. The first tool, ALFA, uses a genetic algorithm to rapidly optimise the parameters of gaussian fits to line profiles. It can fit emission line spectra of arbitrary resolution, wavelength range and depth, with no user input at all. It is well suited to highly multiplexed spectroscopy such as that now being carried out with instruments such as MUSE at the VLT. The second tool, NEAT, carries out a full analysis of emission line fluxes, robustly propagating uncertainties using a Monte Carlo technique.Using these tools, I have found that considerable biases can be introduced into abundance determinations if the uncertainty distribution of emission lines is not well characterised. For weak lines, normally distributed uncertainties are generally assumed, though it is incorrect to do so, and significant biases can result. I discuss observational evidence of these biases. The two new codes contain routines to correctly characterise the probability distributions, giving more reliable results in analyses of emission line nebulae.

  16. Galaxy formation and physical bias

    Science.gov (United States)

    Cen, Renyue; Ostriker, Jeremiah P.

    1992-01-01

    We have supplemented our code, which computes the evolution of the physical state of a representative piece of the universe to include, not only the dynamics of dark matter (with a standard PM code), and the hydrodynamics of the gaseous component (including detailed collisional and radiative processes), but also galaxy formation on a heuristic but plausible basis. If, within a cell the gas is Jeans' unstable, collapsing, and cooling rapidly, it is transformed to galaxy subunits, which are then followed with a collisionless code. After grouping them into galaxies, we estimate the relative distributions of galaxies and dark matter and the relative velocities of galaxies and dark matter. In a large scale CDM run of 80/h Mpc size with 8 x 10 exp 6 cells and dark matter particles, we find that physical bias b is on the 8/h Mpc scale is about 1.6 and increases towards smaller scales, and that velocity bias is about 0.8 on the same scale. The comparable HDM simulation is highly biased with b = 2.7 on the 8/h Mpc scale. Implications of these results are discussed in the light of the COBE observations which provide an accurate normalization for the initial power spectrum. CDM can be ruled out on the basis of too large a predicted small scale velocity dispersion at greater than 95 percent confidence level.

  17. Opinion dynamics with confirmation bias.

    Directory of Open Access Journals (Sweden)

    Armen E Allahverdyan

    Full Text Available Confirmation bias is the tendency to acquire or evaluate new information in a way that is consistent with one's preexisting beliefs. It is omnipresent in psychology, economics, and even scientific practices. Prior theoretical research of this phenomenon has mainly focused on its economic implications possibly missing its potential connections with broader notions of cognitive science.We formulate a (non-Bayesian model for revising subjective probabilistic opinion of a confirmationally-biased agent in the light of a persuasive opinion. The revision rule ensures that the agent does not react to persuasion that is either far from his current opinion or coincides with it. We demonstrate that the model accounts for the basic phenomenology of the social judgment theory, and allows to study various phenomena such as cognitive dissonance and boomerang effect. The model also displays the order of presentation effect-when consecutively exposed to two opinions, the preference is given to the last opinion (recency or the first opinion (primacy -and relates recency to confirmation bias. Finally, we study the model in the case of repeated persuasion and analyze its convergence properties.The standard Bayesian approach to probabilistic opinion revision is inadequate for describing the observed phenomenology of persuasion process. The simple non-Bayesian model proposed here does agree with this phenomenology and is capable of reproducing a spectrum of effects observed in psychology: primacy-recency phenomenon, boomerang effect and cognitive dissonance. We point out several limitations of the model that should motivate its future development.

  18. Composite Electrodes for Electrochemical Supercapacitors

    Directory of Open Access Journals (Sweden)

    Yang QuanMin

    2010-01-01

    Full Text Available Abstract Manganese dioxide nanofibers with length ranged from 0.1 to 1 μm and a diameter of about 4–6 nm were prepared by a chemical precipitation method. Composite electrodes for electrochemical supercapacitors were fabricated by impregnation of the manganese dioxide nanofibers and multiwalled carbon nanotubes (MWCNT into porous Ni plaque current collectors. Obtained composite electrodes, containing 85% of manganese dioxide and 15 mass% of MWCNT, as a conductive additive, with total mass loading of 7–15 mg cm−2, showed a capacitive behavior in 0.5-M Na2SO4 solutions. The decrease in stirring time during precipitation of the nanofibers resulted in reduced agglomeration and higher specific capacitance (SC. The highest SC of 185 F g−1 was obtained at a scan rate of 2 mV s−1 for mass loading of 7 mg cm−2. The SC decreased with increasing scan rate and increasing electrode mass.

  19. Composite Electrodes for Electrochemical Supercapacitors

    Science.gov (United States)

    Li, Jun; Yang, Quan Min; Zhitomirsky, Igor

    2010-03-01

    Manganese dioxide nanofibers with length ranged from 0.1 to 1 μm and a diameter of about 4-6 nm were prepared by a chemical precipitation method. Composite electrodes for electrochemical supercapacitors were fabricated by impregnation of the manganese dioxide nanofibers and multiwalled carbon nanotubes (MWCNT) into porous Ni plaque current collectors. Obtained composite electrodes, containing 85% of manganese dioxide and 15 mass% of MWCNT, as a conductive additive, with total mass loading of 7-15 mg cm-2, showed a capacitive behavior in 0.5-M Na2SO4 solutions. The decrease in stirring time during precipitation of the nanofibers resulted in reduced agglomeration and higher specific capacitance (SC). The highest SC of 185 F g-1 was obtained at a scan rate of 2 mV s-1 for mass loading of 7 mg cm-2. The SC decreased with increasing scan rate and increasing electrode mass.

  20. An experimental study of spider-related covariation bias in 8-to 13-year-old children

    NARCIS (Netherlands)

    Muris, Peter; de Jong, Peter J.; Meesters, Cor; Waterreus, Bregje; van Lubeck, Janet

    2005-01-01

    Covariation bias can be defined as phobic subjects' tendency to overestimate the association between phobic stimuli and aversive outcomes. The current study presents two experiments that examined this type of cognitive bias in children aged 8-13 years (N = 147 in Experiment 1, N = 240 in Experiment

  1. Mixed bi-material electrodes based on LiMn2O4 and activated carbon for hybrid electrochemical energy storage devices

    International Nuclear Information System (INIS)

    Cericola, Dario; Novak, Petr; Wokaun, Alexander; Koetz, Ruediger

    2011-01-01

    Highlights: → Bi-material electrodes for electrochemical hybrid devices were characterized. → Bi-material electrodes have higher specific charge than capacitor electrodes. → Bi-material electrodes have better rate capability than battery electrodes. → Bi-material systems outperform batteries and capacitors in pulsed applications. - Abstract: The performance of mixed bi-material electrodes composed of the battery material, LiMn 2 O 4 , and the electrochemical capacitor material, activated carbon, for hybrid electrochemical energy storage devices is investigated by galvanostatic charge/discharge and pulsed discharge experiments. Both, a high and a low conductivity lithium-containing electrolyte are used. The specific charge of the bi-material electrode is the linear combination of the specific charges of LiMn 2 O 4 and activated carbon according to the electrode composition at low discharge rates. Thus, the specific charge of the bi-material electrode falls between the specific charge of the activated carbon electrode and the LiMn 2 O 4 battery electrode. The bi-material electrodes have better rate capability than the LiMn 2 O 4 battery electrode. For high current pulsed applications the bi-material electrodes typically outperform both the battery and the capacitor electrode.

  2. Ombud’s Corner: defeating unconscious bias

    CERN Document Server

    Sudeshna Datta-Cockerill

    2016-01-01

    Do you have a tendency to switch off at meetings every time a particular colleague starts to speak? Is it obvious to you that your colleagues will never accept a peer as a project leader? And doesn’t that candidate from your own alma mater clearly have a definite edge over the others?   How do we come to these conclusions and what can we do to ensure that our decisions are based on objective criteria alone? Can we always be sure that we are not influenced by pre-conceived notions or prejudices that may unconsciously bias our thinking? Unconscious bias is a part of everyday life – it refers to the insidious influences that our backgrounds, cultural environments or personal experiences exert on the way in which we judge or assess people or situations. In the workplace, it has a negative impact on our goals and interactions when it causes us to make decisions based on generalisations or mental associations that we are not even aware of, and that have little or no bearing on the o...

  3. Bias During the Evaluation of Animal Studies?

    Directory of Open Access Journals (Sweden)

    Andrew Knight

    2012-02-01

    Full Text Available My recent book entitled The Costs and Benefits of Animal Experiments seeks to answer a key question within animal ethics, namely: is animal experimentation ethically justifiable? Or, more precisely, is it justifiable within the utilitarian cost:benefit framework that fundamentally underpins most regulations governing animal experimentation? To answer this question I reviewed more than 500 scientific publications describing animal studies, animal welfare impacts, and alternative research, toxicity testing and educational methodologies. To minimise bias I focused primarily on large-scale systematic reviews that had examined the human clinical and toxicological utility of animal studies. Despite this, Dr. Susanne Prankel recently reviewed my book in this journal, essentially accusing me of bias. However, she failed to provide any substantive evidence to refute my conclusions, let alone evidence of similar weight to that on which they are based. Those conclusions are, in fact, firmly based on utilitarian ethical reasoning, informed by scientific evidence of considerable strength, and I believe they are robust.

  4. Electronic properties of a biased graphene bilayer

    International Nuclear Information System (INIS)

    Castro, Eduardo V; Lopes dos Santos, J M B; Novoselov, K S; Morozov, S V; Geim, A K; Peres, N M R; Nilsson, Johan; Castro Neto, A H; Guinea, F

    2010-01-01

    We study, within the tight-binding approximation, the electronic properties of a graphene bilayer in the presence of an external electric field applied perpendicular to the system-a biased bilayer. The effect of the perpendicular electric field is included through a parallel plate capacitor model, with screening correction at the Hartree level. The full tight-binding description is compared with its four-band and two-band continuum approximations, and the four-band model is shown to always be a suitable approximation for the conditions realized in experiments. The model is applied to real biased bilayer devices, made out of either SiC or exfoliated graphene, and good agreement with experimental results is found, indicating that the model is capturing the key ingredients, and that a finite gap is effectively being controlled externally. Analysis of experimental results regarding the electrical noise and cyclotron resonance further suggests that the model can be seen as a good starting point for understanding the electronic properties of graphene bilayer. Also, we study the effect of electron-hole asymmetry terms, such as the second-nearest-neighbour hopping energies t' (in-plane) and γ 4 (inter-layer), and the on-site energy Δ.

  5. Ensemble and Bias-Correction Techniques for Air-Quality Model Forecasts of Surface O3 and PM2.5 during the TEXAQS-II Experiment of 2006

    Science.gov (United States)

    Several air quality forecasting ensembles were created from seven models, running in real-time during the 2006 Texas Air Quality (TEXAQS-II) experiment. These multi-model ensembles incorporated a diverse set of meteorological models, chemical mechanisms, and emission inventories...

  6. Development of large area resistive electrodes for ATLAS NSW Micromegas

    Science.gov (United States)

    Ochi, Atsuhiko

    2018-02-01

    Micromegas with resistive anodes will be used for the NSW upgrades of the ATLAS experiment at LHC. Resistive electrodes are used in MPGD devices to prevent sparks in high-rate operation. Large-area resistive electrodes for Micromegas have been developed using two different technologies: screen printing and carbon sputtering. The maximum resistive foil size is 45 × 220 cm with a printed pattern of 425-μm pitch strips. These technologies are also suitable for mass production. Prototypes of a production model series have been successfully produced. In this paper, we report the development, the production status, and the test results of resistive Micromegas.

  7. Electrodes for Semiconductor Gas Sensors

    Science.gov (United States)

    Lee, Sung Pil

    2017-01-01

    The electrodes of semiconductor gas sensors are important in characterizing sensors based on their sensitivity, selectivity, reversibility, response time, and long-term stability. The types and materials of electrodes used for semiconductor gas sensors are analyzed. In addition, the effect of interfacial zones and surface states of electrode–semiconductor interfaces on their characteristics is studied. This study describes that the gas interaction mechanism of the electrode–semiconductor interfaces should take into account the interfacial zone, surface states, image force, and tunneling effect. PMID:28346349

  8. Matrilateral Bias in Human Grandmothering

    Directory of Open Access Journals (Sweden)

    Martin Daly

    2017-09-01

    Full Text Available Children receive more care and resources from their maternal grandmothers than from their paternal grandmothers. This asymmetry is the “matrilateral bias” in grandmaternal investment. Here, we synopsize the evolutionary theories that predict such a bias, and review evidence of its cross-cultural generality and magnitude. Evolutionists have long maintained that investing in a daughter’s child yields greater fitness returns, on average, than investing in a son’s child because of paternity uncertainty: the son’s putative progeny may have been sired by someone else. Recent theoretical work has identified an additional natural selective basis for the matrilateral bias that may be no less important: supporting grandchildren lightens the load on their mother, increasing her capacity to pursue her fitness in other ways, and if she invests those gains either in her natal relatives or in children of a former or future partner, fitness returns accrue to the maternal, but not the paternal, grandmother. In modern democracies, where kinship is reckoned bilaterally and no postmarital residence norms restrict grandmaternal access to grandchildren, many studies have found large matrilateral biases in contact, childcare, and emotional closeness. In other societies, patrilineal ideology and postmarital residence with the husband’s kin (virilocality might be expected to have produced a patrilateral bias instead, but the available evidence refutes this hypothesis. In hunter-gatherers, regardless of professed norms concerning kinship and residence, mothers get needed help at and after childbirth from their mothers, not their mothers-in-law. In traditional agricultural and pastoral societies, patrilineal and virilocal norms are common, but young mothers still turn to their natal families for crucial help, and several studies have documented benefits, including reduced child mortality, associated with access to maternal, but not paternal, grandmothers. Even

  9. Nanofiber membrane-electrode-assembly and method of fabricating same

    Energy Technology Data Exchange (ETDEWEB)

    Pintauro, Peter N.; Ballengee, Jason; Brodt, Matthew

    2018-01-23

    In one aspect of the present invention, a method of fabricating a fuel cell membrane-electrode-assembly (MEA) having an anode electrode, a cathode electrode, and a membrane disposed between the anode electrode and the cathode electrode, includes fabricating each of the anode electrode, the cathode electrode, and the membrane separately by electrospinning; and placing the membrane between the anode electrode and the cathode electrode, and pressing then together to form the fuel cell MEA.

  10. "Fair Play": A Videogame Designed to Address Implicit Race Bias Through Active Perspective Taking.

    Science.gov (United States)

    Gutierrez, Belinda; Kaatz, Anna; Chu, Sarah; Ramirez, Dennis; Samson-Samuel, Clem; Carnes, Molly

    2014-12-01

    Having diverse faculty in academic health centers will help diversify the healthcare workforce and reduce health disparities. Implicit race bias is one factor that contributes to the underrepresentation of Black faculty. We designed the videogame "Fair Play" in which players assume the role of a Black graduate student named Jamal Davis. As Jamal, players experience subtle race bias while completing "quests" to obtain a science degree. We hypothesized that participants randomly assigned to play the game would have greater empathy for Jamal and lower implicit race bias than participants randomized to read narrative text describing Jamal's experience. University of Wisconsin-Madison graduate students were recruited via e-mail and randomly assigned to play "Fair Play" or read narrative text through an online link. Upon completion, participants took an Implicit Association Test to measure implicit bias and answered survey questions assessing empathy toward Jamal and awareness of bias. As hypothesized, gameplayers showed the least implicit bias but only when they also showed high empathy for Jamal (P=0.013). Gameplayers did not show greater empathy than text readers, and women in the text condition reported the greatest empathy for Jamal (P=0.008). However, high empathy only predicted lower levels of implicit bias among those who actively took Jamal's perspective through gameplay (P=0.014). A videogame in which players experience subtle race bias as a Black graduate student has the potential to reduce implicit bias, possibly because of a game's ability to foster empathy through active perspective taking.

  11. Culture Moderates Biases in Search Decisions.

    Science.gov (United States)

    Pattaratanakun, Jake A; Mak, Vincent

    2015-08-01

    Prior studies suggest that people often search insufficiently in sequential-search tasks compared with the predictions of benchmark optimal strategies that maximize expected payoff. However, those studies were mostly conducted in individualist Western cultures; Easterners from collectivist cultures, with their higher susceptibility to escalation of commitment induced by sunk search costs, could exhibit a reversal of this undersearch bias by searching more than optimally, but only when search costs are high. We tested our theory in four experiments. In our pilot experiment, participants generally undersearched when search cost was low, but only Eastern participants oversearched when search cost was high. In Experiments 1 and 2, we obtained evidence for our hypothesized effects via a cultural-priming manipulation on bicultural participants in which we manipulated the language used in the program interface. We obtained further process evidence for our theory in Experiment 3, in which we made sunk costs nonsalient in the search task-as expected, cross-cultural effects were largely mitigated. © The Author(s) 2015.

  12. Bias-correction in vector autoregressive models

    DEFF Research Database (Denmark)

    Engsted, Tom; Pedersen, Thomas Quistgaard

    2014-01-01

    We analyze the properties of various methods for bias-correcting parameter estimates in both stationary and non-stationary vector autoregressive models. First, we show that two analytical bias formulas from the existing literature are in fact identical. Next, based on a detailed simulation study......, we show that when the model is stationary this simple bias formula compares very favorably to bootstrap bias-correction, both in terms of bias and mean squared error. In non-stationary models, the analytical bias formula performs noticeably worse than bootstrapping. Both methods yield a notable...... improvement over ordinary least squares. We pay special attention to the risk of pushing an otherwise stationary model into the non-stationary region of the parameter space when correcting for bias. Finally, we consider a recently proposed reduced-bias weighted least squares estimator, and we find...

  13. The Probability Distribution for a Biased Spinner

    Science.gov (United States)

    Foster, Colin

    2012-01-01

    This article advocates biased spinners as an engaging context for statistics students. Calculating the probability of a biased spinner landing on a particular side makes valuable connections between probability and other areas of mathematics. (Contains 2 figures and 1 table.)

  14. Short Communication: Gender Bias and Stigmatization against ...

    African Journals Online (AJOL)

    Short Communication: Gender Bias and Stigmatization against Women Living with ... In Ethiopia, HIV/AIDS is highly stigmatized due to the fact that sexual ... bias, socio-economic situations and traditional beliefs contribute, individually and in ...

  15. Demand artifact: objectively detecting biased participants in advertising research.

    Science.gov (United States)

    Miller, Felicia; Schertzer, Susan

    2014-12-01

    Detecting and reducing the effect of biased participants continues to be an important task for researchers. However, the lack of objective measures to assess demand artifact has made it difficult to effectively address this issue. This paper reports two experiments that apply a theory-based post-experimental inquiry that can systematically identify biased participants in consumer research. The results demonstrate how easily and effectively researchers can incorporate this tool into experimental studies of all types and reduce the likelihood of systematic error.

  16. Is there bias in editorial choice? Yes

    OpenAIRE

    Moustafa, Khaled

    2018-01-01

    Nature has recently published a Correspondence claiming the absence of fame biases in the editorial choice. The topic is interesting and deserves a deeper analysis than it was presented because the reported brief analysis and its conclusion are somewhat biased for many reasons, some of them are discussed here. Since the editorial assessment is a form of peer-review, the biases reported on external peer-reviews would, thus, apply to the editorial assessment, too. The biases would be proportion...

  17. Bias-field equalizer for bubble memories

    Science.gov (United States)

    Keefe, G. E.

    1977-01-01

    Magnetoresistive Perm-alloy sensor monitors bias field required to maintain bubble memory. Sensor provides error signal that, in turn, corrects magnitude of bias field. Error signal from sensor can be used to control magnitude of bias field in either auxiliary set of bias-field coils around permanent magnet field, or current in small coils used to remagnetize permanent magnet by infrequent, short, high-current pulse or short sequence of pulses.

  18. In situ electrochemical atomic force microscope study on graphite electrodes

    Energy Technology Data Exchange (ETDEWEB)

    Hirasawa, K.A.; Sato, Tomohiro; Asahina, Hitoshi; Yamaguchi, Shoji; Mori, Shoichiro [Mitsubishi Chemical Corp., Inashiki, Ibaraki (Japan). Tsukuba Research Center

    1997-04-01

    Interest in the formation of the solid electrolyte interphase (SEI) film on graphite electrodes has increased recently in the quest to improve the performance of lithium-ion batteries. Topographic and frictional changes on the surface of a highly oriented pyrolytic graphite electrode in 1 M LiCiO{sub 4} ethylene carbonate/ethylmethyl carbonate (1:1) electrolyte were examined during charge and discharge by in situ electrochemical atomic force microscopy and friction force microscopy simultaneously in real-time. Solid electrolyte interphase film formation commenced at approximately 2 V vs. Li/Li{sup +} and stable film formation with an island-like morphology was observed below approximately 0.9 V vs. Li/Li{sup +}. Further experiments on a KS-44 graphite/polyvinylidene difluoride binder composite electrode showed similar phenomena.

  19. Carbon electrode for desalination purpose in capacitive deionization

    International Nuclear Information System (INIS)

    Endarko,; Fadilah, Nurul; Anggoro, Diky

    2016-01-01

    Carbon electrodes for desalination purpose have been successfully synthesized using activated carbon powder (BET surface area=700 – 1400 m 2 /g), carbon black and polyvinyl alcohol (PVA) binder by cross-linking method with glutaric acid (GA) at 120 °C. The electrochemical properties of the carbon electrodes were analyzed using electrical impedance spectroscopy (EIS) and cyclic voltammetry (CV) whilst the physical properties were observed with scanning electron microscopy with energy dispersive X-ray spectroscopy (SEM/EDX). In order to assess the desalting performance, salt removal experiments were performed by constructing a capacitive deionization unit cell with five pairs of carbon electrodes. For each pair consisted of two parallel carbon electrodes separated by a spacer. Desalination and regeneration processes were also observed in the salt-removal experiments. The salt-removal experiments were carried out in single-pass mode using a solution with 0.1 M NaCl at a flow rate of 10 mL/min. A voltage of 3 V was applied to the cell for 60 minutes for both processes in desalination and regeneration. The result showed that the percentage value of the salt-removal was achieved at 20%.

  20. Carbon electrode for desalination purpose in capacitive deionization

    Energy Technology Data Exchange (ETDEWEB)

    Endarko,, E-mail: endarko@physics.its.ac.id; Fadilah, Nurul; Anggoro, Diky [Physics Department, Institut Teknologi Sepuluh Nopember (ITS) Kampus ITS, Sukolilo Surabaya 60111, Jawa Timur (Indonesia)

    2016-03-11

    Carbon electrodes for desalination purpose have been successfully synthesized using activated carbon powder (BET surface area=700 – 1400 m{sup 2}/g), carbon black and polyvinyl alcohol (PVA) binder by cross-linking method with glutaric acid (GA) at 120 °C. The electrochemical properties of the carbon electrodes were analyzed using electrical impedance spectroscopy (EIS) and cyclic voltammetry (CV) whilst the physical properties were observed with scanning electron microscopy with energy dispersive X-ray spectroscopy (SEM/EDX). In order to assess the desalting performance, salt removal experiments were performed by constructing a capacitive deionization unit cell with five pairs of carbon electrodes. For each pair consisted of two parallel carbon electrodes separated by a spacer. Desalination and regeneration processes were also observed in the salt-removal experiments. The salt-removal experiments were carried out in single-pass mode using a solution with 0.1 M NaCl at a flow rate of 10 mL/min. A voltage of 3 V was applied to the cell for 60 minutes for both processes in desalination and regeneration. The result showed that the percentage value of the salt-removal was achieved at 20%.

  1. Human preferences for symmetry: subjective experience, cognitive conflict and cortical brain activity.

    Directory of Open Access Journals (Sweden)

    David W Evans

    Full Text Available This study examines the links between human perceptions, cognitive biases and neural processing of symmetrical stimuli. While preferences for symmetry have largely been examined in the context of disorders such as obsessive-compulsive disorder and autism spectrum disorders, we examine various these phenomena in non-clinical subjects and suggest that such preferences are distributed throughout the typical population as part of our cognitive and neural architecture. In Experiment 1, 82 young adults reported on the frequency of their obsessive-compulsive spectrum behaviors. Subjects also performed an emotional Stroop or variant of an Implicit Association Task (the OC-CIT developed to assess cognitive biases for symmetry. Data not only reveal that subjects evidence a cognitive conflict when asked to match images of positive affect with asymmetrical stimuli, and disgust with symmetry, but also that their slowed reaction times when asked to do so were predicted by reports of OC behavior, particularly checking behavior. In Experiment 2, 26 participants were administered an oddball Event-Related Potential task specifically designed to assess sensitivity to symmetry as well as the OC-CIT. These data revealed that reaction times on the OC-CIT were strongly predicted by frontal electrode sites indicating faster processing of an asymmetrical stimulus (unparallel lines relative to a symmetrical stimulus (parallel lines. The results point to an overall cognitive bias linking disgust with asymmetry and suggest that such cognitive biases are reflected in neural responses to symmetrical/asymmetrical stimuli.

  2. Electron beam dynamics in an ultrafast transmission electron microscope with Wehnelt electrode

    Energy Technology Data Exchange (ETDEWEB)

    Bücker, K.; Picher, M.; Crégut, O. [Institut de Physique et Chimie des Matériaux de Strasbourg, UMR 7504 CNRS, Université de Strasbourg, 23 rue du Loess, 67034 Strasbourg (France); LaGrange, T. [Interdisciplinary Centre for Electron Microscopy, École Polytechnique Fédérale de Lausanne, 1015 Lausanne (Switzerland); Reed, B.W.; Park, S.T.; Masiel, D.J. [Integrated Dynamic Electron Solutions, Inc., 5653 Stoneridge Drive 117, Pleasanton, CA 94588 (United States); Banhart, F., E-mail: florian.banhart@ipcms.unistra.fr [Institut de Physique et Chimie des Matériaux de Strasbourg, UMR 7504 CNRS, Université de Strasbourg, 23 rue du Loess, 67034 Strasbourg (France)

    2016-12-15

    High temporal resolution transmission electron microscopy techniques have shown significant progress in recent years. Using photoelectron pulses induced by ultrashort laser pulses on the cathode, these methods can probe ultrafast materials processes and have revealed numerous dynamic phenomena at the nanoscale. Most recently, the technique has been implemented in standard thermionic electron microscopes that provide a flexible platform for studying material's dynamics over a wide range of spatial and temporal scales. In this study, the electron pulses in such an ultrafast transmission electron microscope are characterized in detail. The microscope is based on a thermionic gun with a Wehnelt electrode and is operated in a stroboscopic photoelectron mode. It is shown that the Wehnelt bias has a decisive influence on the temporal and energy spread of the picosecond electron pulses. Depending on the shape of the cathode and the cathode-Wehnelt distance, different emission patterns with different pulse parameters are obtained. The energy spread of the pulses is determined by space charge and Boersch effects, given by the number of electrons in a pulse. However, filtering effects due to the chromatic aberrations of the Wehnelt electrode allow the extraction of pulses with narrow energy spreads. The temporal spread is governed by electron trajectories of different length and in different electrostatic potentials. High temporal resolution is obtained by excluding shank emission from the cathode and aberration-induced halos in the emission pattern. By varying the cathode-Wehnelt gap, the Wehnelt bias, and the number of photoelectrons in a pulse, tradeoffs between energy and temporal resolution as well as beam intensity can be made as needed for experiments. Based on the characterization of the electron pulses, the optimal conditions for the operation of ultrafast TEMs with thermionic gun assembly are elaborated. - Highlights: • A detailed characterization of electron

  3. Characterisation of nano-interdigitated electrodes

    Energy Technology Data Exchange (ETDEWEB)

    Skjolding, L H D; Ribayrol, A; Montelius, L [Division of Solid State Physics, Lund University, Box 118, SE-221 00 Lund (Sweden); Spegel, C [Department of Analytical Chemistry Lund University, Box 124, SE-221 00 Lund (Sweden); Emneus, J [MIC - Department of Micro and Nanotechnology, DTU - Building 345 East, DK-2800 Kgs. Lyngby (Denmark)], E-mail: lars_henrik.daehli_skjolding@ftf.lth.se

    2008-03-15

    Interdigitated electrodes made up of two individually addressable interdigitated comb-like electrode structures have frequently been suggested as ultra sensitive electrochemical biosensors. Since the signal enhancement effects due to cycling of the reduced and oxidized species are strongly dependent on the inter electrode distances, since the nature of the enhancement is due to overlying diffusion layers, interdigitated electrodes with an electrode separation of less then one micrometer are desired for maximum signal amplification. Fabrication of submicron structures can only be made by advanced lithography techniques. By use of electron beam lithography we have fabricated arrays of interdigitated electrodes with an electrode separation distance of 200 nm and an electrode finger width of likewise 200 nm. The entire electrode structure is 100 micrometre times 100 micrometre, and the active electrode area is dictated by the opening in the passivation layer, that is defined by UV lithography. Here we report measurements of redox cycling of ferrocyanide by coupled cyclic voltammograms, where the potential at one of the working electrodes are varied and either an oxidising or reducing potential is applied to the complimentary interdigitated electrode. The measurements show fast conversion and high collection efficiency round 87% as expected for nano-interdigitated electrodes.

  4. Angular biasing in implicit Monte-Carlo

    International Nuclear Information System (INIS)

    Zimmerman, G.B.

    1994-01-01

    Calculations of indirect drive Inertial Confinement Fusion target experiments require an integrated approach in which laser irradiation and radiation transport in the hohlraum are solved simultaneously with the symmetry, implosion and burn of the fuel capsule. The Implicit Monte Carlo method has proved to be a valuable tool for the two dimensional radiation transport within the hohlraum, but the impact of statistical noise on the symmetric implosion of the small fuel capsule is difficult to overcome. We present an angular biasing technique in which an increased number of low weight photons are directed at the imploding capsule. For typical parameters this reduces the required computer time for an integrated calculation by a factor of 10. An additional factor of 5 can also be achieved by directing even smaller weight photons at the polar regions of the capsule where small mass zones are most sensitive to statistical noise

  5. The Accuracy Enhancing Effect of Biasing Cues

    NARCIS (Netherlands)

    W. Vanhouche (Wouter); S.M.J. van Osselaer (Stijn)

    2009-01-01

    textabstractExtrinsic cues such as price and irrelevant attributes have been shown to bias consumers’ product judgments. Results in this article replicate those findings in pretrial judgments but show that such biasing cues can improve quality judgments at a later point in time. Initially biasing

  6. Biased managers, organizational design, and incentive provision

    OpenAIRE

    Moreira, Humberto Ataíde; Costa, Cristiano Machado; Ferreira, Daniel Bernardo Soares

    2004-01-01

    Rio de Janeiro We model the tradeoff between the balance and the strength of incentives implicit in the choice between hierarchical and matrix organizational structures. We show that managerial biases determine which structure is optimal: hierarchical forms are preferred when biases are low, while matrix structures are preferred when biases are high.

  7. Can free-viewing perceptual asymmetries be explained by scanning, pre-motor or attentional biases?

    Science.gov (United States)

    Nicholls, Michael E R; Roberts, Georgina R

    2002-04-01

    Judgments of relative magnitude between the left and right sides of a stimulus are generally weighted toward the features contained on the left side. This leftward perceptual bias could be the result of, (a) left-to-right scanning biases, (b) pre-motor activation of the right hemisphere, or (c) a left hemispatial attentional bias. The relative merits of these explanations of perceptual asymmetry were investigated. In Experiment 1, English and Hebrew readers made luminance judgements for two left/right mirror-reversed luminance gradients (greyscales task). Despite different reading/scanning habits, both groups exhibited a leftward perceptual bias. English and Hebrew readers also performed a line bisection task. Scanning biases were controlled by asking participants to follow a marker as it moved left-to-right or right-to-left and then stop it as it reached the midpoint of the line. Despite controlling scanning, a leftward bias was observed in both groups. In Experiment 2, peripheral spatial cues were presented prior to the greyscales stimuli. English readers showed a reduction in the leftward bias for right-sided cues as compared to left-sided and neutral cues. Right-side cues presumably overcame a pre-existing leftward attentional bias. In both experiments, pre-motor activation was controlled using bimanual responses. Despite this control, a leftward bias was observed throughout the study. The data support the attentional bias account of leftward perceptual biases over the scanning and pre-motor activation accounts. Whether or not unilateral hemispheric activation provides an adequate account of this attentional bias is discussed.

  8. High power nickel - cadmium cells with fiber electrodes (FNC)

    International Nuclear Information System (INIS)

    Haschka, F.; Schlieck, D.

    1986-01-01

    Nickel cadmium batteries differ greatly in their mechanical design and construction of the electrodes. Using available electrode constructions, batteries are designed which meet the requirements of specific applications and offer optimum performance. Pocket- and tubular cells are basically developed with the technology of the year 1895. Since then some improvements with todays technology have been made. The sintered cells use the technology of the 1930's and they are still limited to high power application. With this knowledge and the technology of today the fiber-structured nickel electrode (FNC) was developed at DAUG laboratory, a subsidiary company of Mercedes-Benz and Volkswagen. After ten years of experience in light weight prototype batteries for electric vehicles (1-2), the system was brought into production by a new company, DAUG-HOPPECKE. Characteristics of fiber electrodes: thickness and size can be easily changed; pure active materials are used; high conductor density; high elasticity of the structure; high porosity. Since 1983 NiCd-batteries with fiber-structured nickel electrodes (FNC) have been in production. Starting with the highly demanded cell-types for low, medium and high performance called L, M and H according to IEC 623 for low, medium and high performance applications, the program was recently completed with the X-type cell for very high power, as an alternative to sintered cells

  9. Multi-Electrode Impedance Method for Detection of Regional Ventilation

    International Nuclear Information System (INIS)

    Furuya, Norio; Sakamoto, Katsuyuki

    2013-01-01

    By means of computer simulation and experiment, we investigated the feasibility of simultaneously measuring the transfer impedance changes in the right apex, left apex, right base and left base of the lungs using the multi-electrode impedance method. To obtain the transfer impedance in each region, while suppressing the effects of other regions, changing the amplitude and polarity of the applied current must localize the high sensitivity areas in the interest region. Twelve current and eight voltage electrodes were equidistantly arranged on the anterior and posterior chest walls. The amplitudes and polarities of the currents that were simultaneously applied to the current electrodes, and which provided the appropriate sensitivity distribution, were theoretically obtained. The effects of the localized sensitivity distribution were verified by comparing the simulation results of the investigated method with the results of the conventional four-electrode method. From the results of the computer simulation, we developed a multi-electrode impedance pneumography and applied it to healthy adult volunteers who were both in sitting position and in left decubitus. We found that the measurement results were physiologically reasonable.

  10. Broad Considerations Concerning Electrochemical Electrodes in Primarily Fluid Environments

    Directory of Open Access Journals (Sweden)

    Christopher G. Jesudason

    2009-05-01

    Full Text Available This review is variously a presentation, reflection, synthesis and report with reference to more recent developments of an article – in a journal which has ceased publication – entitled “Some Electrode Theorems with Experimental Corroboration, Inclusive of the Ag/AgCl System” Internet Journal of Chemistry, (http://www.ijc.com, Special Issues: Vol. 2 Article 24 (1999. The results from new lemmas relating charge densities and capacitance in a metallic electrode in equilibrium with an ionic solution are used to explain the data and observed effects due to Esin, Markov, Grahame, Lang and Kohn. Size effects that vary the measured e.m.f. of electrodes due to changes in the electronic chemical potential are demonstrated in experiment and theory implying the need for standardization of electrodes with respect to geometry and size. The widely used Stern modification of the Gouy-Chapman theory is shown to be mostly inapplicable for many of the problems where it is employed. Practical consequences of the current development include the possibility of determining the elusive single-ion activity coefficients of solution ions directly from the expression given by a simplified capacitance theorem, the potential of zero charge and the determination of single ion concentrations of active species in the electrode reactions from cell e.m.f. measurements.

  11. High Temperature Electrolysis using Electrode-Supported Cells

    International Nuclear Information System (INIS)

    O'Brien, J.E.; Stoots, C.M.

    2010-01-01

    An experimental study is under way to assess the performance of electrode-supported solid-oxide cells operating in the steam electrolysis mode for hydrogen production. The cells currently under study were developed primarily for the fuel cell mode of operation. Results presented in this paper were obtained from single cells, with an active area of 16 cm2 per cell. The electrolysis cells are electrode-supported, with yttria-stabilized zirconia (YSZ) electrolytes (∼10 (micro)m thick), nickel-YSZ steam/hydrogen electrodes (∼1400 (micro)m thick), and manganite (LSM) air-side electrodes (∼90 (micro)m thick). The purpose of the present study was to document and compare the performance and degradation rates of these cells in the fuel cell mode and in the electrolysis mode under various operating conditions. Initial performance was documented through a series of DC potential sweeps and AC impedance spectroscopy measurements. Degradation was determined through long-duration testing, first in the fuel cell mode, then in the electrolysis mode over more than 500 hours of operation. Results indicate accelerated degradation rates in the electrolysis mode compared to the fuel cell mode, possibly due to electrode delamination. The paper also includes details of the single-cell test apparatus developed specifically for these experiments.

  12. Electrodes Modification Based on Metal-Free Phthalocyanine: Example of Electrochemical Sensors for the Detection of Acetic Acid

    Directory of Open Access Journals (Sweden)

    Amadou L. Ndiaye

    2015-01-01

    Full Text Available Electroanalytical properties of tetra-tert-butyl phthalocyanine (PcH2-tBu modified electrodes are studied by cyclic voltammetry (CV. The modified electrodes are obtained by CV deposition techniques on gold (Au and glassy carbon (C screen-printed electrodes (SPEs and used for the electrochemical detection of acetic acid (AA. Based on the CV experiments, the electrodeposition mechanism is detailed. The modified PcH2-tBu electrodes reveal one oxidation and one reduction peak within the potential window of the working electrodes. In the presence of the analyte (acetic acid, the modified electrodes show sensitivity in the range of 10 mM to 400 mM. For the PcH2-tBu modified Au electrode, a limit of detection (LOD of 5.89 mM (based on the +0.06 V peak was obtained while for the PcH2-tBu modified C electrode a LOD of 17.76 mM (based on the +0.07 V peak was achieved. A signal decay of 17%, based on 20 experiments, is obtained when gold is used as working electrode. If carbon is used as working electrode a value of 7% is attained. A signal decay is observed after more than 50 cycles of experiments and is more pronounced when higher concentrations of acetic acid are used. A mechanism of sensing is proposed at the end.

  13. A fundamental residue pitch perception bias for tone language speakers

    Science.gov (United States)

    Petitti, Elizabeth

    A complex tone composed of only higher-order harmonics typically elicits a pitch percept equivalent to the tone's missing fundamental frequency (f0). When judging the direction of residue pitch change between two such tones, however, listeners may have completely opposite perceptual experiences depending on whether they are biased to perceive changes based on the overall spectrum or the missing f0 (harmonic spacing). Individual differences in residue pitch change judgments are reliable and have been associated with musical experience and functional neuroanatomy. Tone languages put greater pitch processing demands on their speakers than non-tone languages, and we investigated whether these lifelong differences in linguistic pitch processing affect listeners' bias for residue pitch. We asked native tone language speakers and native English speakers to perform a pitch judgment task for two tones with missing fundamental frequencies. Given tone pairs with ambiguous pitch changes, listeners were asked to judge the direction of pitch change, where the direction of their response indicated whether they attended to the overall spectrum (exhibiting a spectral bias) or the missing f0 (exhibiting a fundamental bias). We found that tone language speakers are significantly more likely to perceive pitch changes based on the missing f0 than English speakers. These results suggest that tone-language speakers' privileged experience with linguistic pitch fundamentally tunes their basic auditory processing.

  14. Auditory hindsight bias: Fluency misattribution versus memory reconstruction.

    Science.gov (United States)

    Higham, Philip A; Neil, Greg J; Bernstein, Daniel M

    2017-06-01

    We report 4 experiments investigating auditory hindsight bias-the tendency to overestimate the intelligibility of distorted auditory stimuli after learning their identity. An associative priming manipulation was used to vary the amount of processing fluency independently of prior target knowledge. For hypothetical designs, in which hindsight judgments are made for peers in foresight, we predicted that judgments would be based on processing fluency and that hindsight bias would be greater in the unrelated- compared to related-prime context (differential-fluency hypothesis). Conversely, for memory designs, in which foresight judgments are remembered in hindsight, we predicted that judgments would be based on memory reconstruction and that there would be independent effects of prime relatedness and prior target knowledge (recollection hypothesis). These predictions were confirmed. Specifically, we found support for the differential-fluency hypothesis when a hypothetical design was used in Experiments 1 and 2 (hypothetical group). Conversely, when a memory design was used in Experiments 2 (memory group), 3A, and 3B, we found support for the recollection hypothesis. Together, the results suggest that qualitatively different mechanisms create hindsight bias in the 2 designs. The results are discussed in terms of fluency misattributions, memory reconstruction, anchoring-and-adjustment, sense making, and a multicomponent model of hindsight bias. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  15. Performance capabilities of EDM of high carbon high chromium steel with copper and brass electrodes

    Science.gov (United States)

    Surekha, B.; Swain, Sudiptha; Suleman, Abu Jafar; Choudhury, Suvan Dev

    2017-07-01

    The paper address the statistical modeling of input-output relationships of electric discharge machining. In the present work, peak current (I) pulse on time (T) and gap voltage of electric discharge machining (EDM) process are chosen as control parameters to analyze the performance of the process. The output characteristics, namely radial overcut, electrode wear rate (EWR) and metal removal rate (MRR) are treated as the responses. A full factorial design (FFD) of experiments has been used to conduct the experiments and linear regression models are developed for different process characteristics. While conducting the experiments, high carbon and high chromium steel is considered as work piece material and brass and copper are used as electrode material. It is important to note that the experimental conditions are kept similar while machining with the help of different electrode materials. The data obtained from the experiments has been used to develop the regression models for three process parameters for two electrode materials.

  16. IDENTIFICATION OF CHLOROMETHANE FORMATION PATHS DURING ELECTROCHEMICAL DECHLORINATION OF TCE USING GRAPHITE ELECTRODES

    Science.gov (United States)

    The purpose of this research is to investigate the formation of chloromethane during TCE dechlorination in a mixed electrochemical reactor using graphite electrodes. Chloromethane was the major chlorinated organic compound detected in previous dechlorination experiments. In order...

  17. IDENTIFICATION OF CHLOROMETHANE FROMATION PATHS DURING ELECTROCHEMICAL DECHLORINATION OF TCE USING GRAPHITE ELECTRODES

    Science.gov (United States)

    The purpose of this research is to investigate the formation of chloromethane during TCE dechlorination in a mixed electrochemical reactor using graphite electrodes. Chloromethane was the major chlorinated organic compound detected in previous dechlorination experiments. In order...

  18. Progress in understanding SOFC electrodes

    DEFF Research Database (Denmark)

    Mogensen, Mogens Bjerg; Hansen, Karin Vels; Jørgensen, M.J.

    2002-01-01

    The literature of SOFC electrode kinetics and mechanisms is full of contradicting details in case of both the SOFC anode and cathode processes. Only weak patterns may be identified. One interpretation is that each of the reported data sets reflects a laboratory specific nature of each of the elec...

  19. Anodized Steel Electrodes for Supercapacitors.

    Science.gov (United States)

    Sagu, Jagdeep S; Wijayantha, K G Upul; Bohm, Mallika; Bohm, Siva; Kumar Rout, Tapan

    2016-03-09

    Steel was anodized in 10 M NaOH to enhance its surface texture and internal surface area for application as an electrode in supercapacitors. A mechanism was proposed for the anodization process. Field-emission gun scanning electron microscopy (FEGSEM) studies of anodized steel revealed that it contains a highly porous sponge like structure ideal for supercapacitor electrodes. X-ray photoelectron spectroscopy (XPS) measurements showed that the surface of the anodized steel was Fe2O3, whereas X-ray diffraction (XRD) measurements indicated that the bulk remained as metallic Fe. The supercapacitor performance of the anodized steel was tested in 1 M NaOH and a capacitance of 18 mF cm(-2) was obtained. Cyclic voltammetry measurements showed that there was a large psueudocapacitive contribution which was due to oxidation of Fe to Fe(OH)2 and then further oxidation to FeOOH, and the respective reduction of these species back to metallic Fe. These redox processes were found to be remarkably reversible as the electrode showed no loss in capacitance after 10000 cycles. The results demonstrate that anodization of steel is a suitable method to produce high-surface-area electrodes for supercapacitors with excellent cycling lifetime.

  20. Advanced screening of electrode couples

    Science.gov (United States)

    Giner, J. D.; Cahill, K.

    1980-01-01

    The chromium (Cr(3+)/Cr(2+)) redox couple (electrolyte and electrode) was investigated to determine its suitability as negative electrode for the iron (Fe(3+)/Fe(2+))-chromium (Cr(3+)/Cr(2+)) redox flow battery. Literature search and laboratory investigation established that the solubility and stability of aqueous acidic solutions of chromium(3) chloride and chromium(2) chloride are sufficient for redox battery application. Four categories of electrode materials were tested; namely, metals and metalloid materials (elements and compounds), alloys, plated materials, and Teflon-bonded materials. In all, the relative performance of 26 candidate electrode materials was evaluated on the basis of slow scan rate linear sweep voltammetry in stirred solution. No single material tested gave both acceptable anodic an acceptable cathodic performance. However, the identification of lead as a good cathodic electrocatalyst and gold as a good anodic electrocatalyst led to the invention of the lead/gold combination electrocatalyst. This type of catalyst can be fabricated in several ways and appears to offer the advantages of each metal without the disadvantages associated with their use as single materials. This lead/gold electrocatalyst was tested by NASA-Lewis Research Center in complete, flowing, redox batteries comprising a stack of several cells. A large improvement in the battery's coulombic and energy efficiency was observed.

  1. Emotion Regulation Predicts Attention Bias in Maltreated Children At-Risk for Depression

    Science.gov (United States)

    Romens, Sarah E.; Pollak, Seth D.

    2012-01-01

    Background: Child maltreatment is associated with heightened risk for depression; however, not all individuals who experience maltreatment develop depression. Previous research indicates that maltreatment contributes to an attention bias for emotional cues, and that depressed individuals show attention bias for sad cues. Method: The present study…

  2. Attention Bias to Emotional Faces Varies by IQ and Anxiety in Williams Syndrome

    Science.gov (United States)

    McGrath, Lauren M.; Oates, Joyce M.; Dai, Yael G.; Dodd, Helen F.; Waxler, Jessica; Clements, Caitlin C.; Weill, Sydney; Hoffnagle, Alison; Anderson, Erin; MacRae, Rebecca; Mullett, Jennifer; McDougle, Christopher J.; Pober, Barbara R.; Smoller, Jordan W.

    2016-01-01

    Individuals with Williams syndrome (WS) often experience significant anxiety. A promising approach to anxiety intervention has emerged from cognitive studies of attention bias to threat. To investigate the utility of this intervention in WS, this study examined attention bias to happy and angry faces in individuals with WS (N = 46). Results showed…

  3. Lifting the Curtain on the Wizard of Oz: Biased Voice-Based Impressions of Speaker Size

    Science.gov (United States)

    Rendall, Drew; Vokey, John R.; Nemeth, Christie

    2007-01-01

    The consistent, but often wrong, impressions people form of the size of unseen speakers are not random but rather point to a consistent misattribution bias, one that the advertising, broadcasting, and entertainment industries also routinely exploit. The authors report 3 experiments examining the perceptual basis of this bias. The results indicate…

  4. Attentional and affective biases for attractive females emerge early in development.

    Science.gov (United States)

    Rennels, Jennifer Lynn; Verba, Stephanie Ann

    2017-01-01

    Predominant experience with females early in development results in infants developing an attractive, female-like facial representation that guides children's attention toward and affective preferences for attractive females. When combined with increased interest in the other sex at puberty, these early emerging biases might help explain the robust prosocial and financial biases men exhibit toward attractive women during adulthood.

  5. The Impact of Sexual of Orientation and Gender Expression Bias on African American Students

    Science.gov (United States)

    Majied, Kamilah F.

    2010-01-01

    This article discusses sexual orientation and gender expression bias as they impact the educational experience of African American students. Sexual orientation and gender expression bias have a unique presentation in Black educational settings. The climate in such settings can be metagrobolized by the combination of distorted notions of Black…

  6. Study on the Effect of the Three-Dimensional Electrode in Degradation of Methylene Blue by Lithium Modified Rectorite

    Directory of Open Access Journals (Sweden)

    Jian Huang

    2016-01-01

    Full Text Available This study presents the electrochemical degradation of methylene blue (MB wastewater in a synthetic solution using three-dimensional particle electrodes. The novel particle electrodes were fabricated in this work using the lithium modified rectorite (Li-REC. The adsorption property of the fabricated particle electrodes was studied in a series of experiments. The optimum electrochemical operating conditions of plate distance, cell voltage, and concentration of electrolyte were 2 cm, 9 V, and 0.06 mol L−1, respectively. It was also found that microwave irradiation can effectively improve the adsorption property and electrical property of the fabricated electrodes. In addition, the scanning electron microscope (SEM of the fabricated electrodes was investigated. The experimental results revealed the order of adsorption property and electrical property of the fabricated electrodes. So, fabricated electrodes are not only of low cost and mass produced, but also efficient to achieve decolorization of MB solution.

  7. Highly improved electrocatalytic behavior of sulfite at carbon ionic liquid electrode: Application to the analysis of some real samples

    International Nuclear Information System (INIS)

    Safavi, Afsaneh; Maleki, Norouz; Momeni, Safieh; Tajabadi, Fariba

    2008-01-01

    The electrocatalytic oxidation of sulfite was investigated at carbon ionic liquid electrode (CILE). This electrode is a very good alternative to previously described electrodes because the electrocatalytic effect is achieved without any electrode modification. Comparative experiments were carried out using carbon paste electrode (CPE) and glassy carbon electrode (GCE). At CILE, highly reproducible and well-defined cyclic voltammograms were obtained for sulfite with a peak potential of 0.55 V vs. Ag/AgCl. Sulfite oxidation at CILE does not result in deactivation of the electrode surface. The kinetic parameters for this irreversible heterogeneous electron transfer process were determined. Under optimal experimental conditions, the peak current response increased linearly with sulfite concentration over the range of 6-1000 μM. The detection limit of the method was 4 μM. The method was applied to the determination of sulfite in mineral water, grape juice and non-alcoholic beer samples

  8. An experimental investigation of recruitment bias in eating pathology research.

    Science.gov (United States)

    Moss, Erin L; von Ranson, Kristin M

    2006-04-01

    Previous, uncontrolled research has suggested a bias may exist in recruiting participants for eating disorder research. Recruitment biases may affect sample representativeness and generalizability of findings. This experiment investigated whether revealing that a study's topic was related to eating disorders created a self-selection bias. Young women at a university responded to advertisements containing contrasting information about the nature of a single study. We recruited one group by advertising the study under the title "Disordered Eating in Young Women" (n = 251) and another group using the title "Consumer Preferences" (n = 259). Results indicated similar levels of eating pathology in both groups, so the different recruitment techniques did not engender self-selection. However, the consumer preferences group scored higher in self-reported social desirability. The level of information conveyed in study advertising does not impact reporting of eating disturbances among nonclinical samples, although there is evidence social desirability might. 2006 by Wiley Periodicals, Inc.

  9. Strategi Mengatasi Common Measures Bias dalam Balanced Scorecard

    Directory of Open Access Journals (Sweden)

    Sekar Akrom Faradiza

    2016-06-01

    Balanced Scorecard (BSC is a comprehensive performance measurement. BSC is not only used financial indicators but also non financial indicators there are customer, internal process business and learning and growth perspective. By using BSC, evaluators have common and unique measures. When evaluate manager performance, evaluator tends to only use common measures and ignore unique measures. This is called common measures bias. This study aims to investigate whether dissaggregated and aggregated BSC and management communication can overcome common measures bias and intent to BSC approach. This study also will evaluate whether these approach will affect evaluator decision when allocated compensation. We conduct 2x2x2 experiment of undergraduate accounting students. Participant act as a senior manager and evaluate the performance of two divisions and then allocated the bonus. ANOVA repeated measurement are used to conduct hypothesis test. The results showed that dissaggregated BSC and management communication could not overcome common measures bias but effected  management decision when allocated compensation.

  10. Zero bias thermally stimulated currents in synthetic diamond

    Science.gov (United States)

    Mori, R.; Miglio, S.; Bruzzi, M.; Bogani, F.; De Sio, A.; Pace, E.

    2009-06-01

    Zero bias thermally stimulated currents (ZBTSCs) have been observed in single crystal high pressure high temperature (HPHT) and polycrystalline chemical vapor deposited (pCVD) diamond films. The ZBTSC technique is characterized by an increased sensitivity with respect to a standard TSC analysis. Due to the absence of the thermally activated background current, new TSC peaks have been observed in both HPHT and pCVD diamond films, related to shallow activation energies usually obscured by the emission of the dominant impurities. The ZBTSC peaks are explained in terms of defect discharge in the nonequilibrium potential distribution created by a nonuniform traps filling at the metal-diamond junctions. The electric field due to the charged defects has been estimated in a quasizero bias TSC experiment by applying an external bias.

  11. Selection bias in the reported performances of AD classification pipelines

    Directory of Open Access Journals (Sweden)

    Alex F. Mendelson

    2017-01-01

    Full Text Available The last decade has seen a great proliferation of supervised learning pipelines for individual diagnosis and prognosis in Alzheimer's disease. As more pipelines are developed and evaluated in the search for greater performance, only those results that are relatively impressive will be selected for publication. We present an empirical study to evaluate the potential for optimistic bias in classification performance results as a result of this selection. This is achieved using a novel, resampling-based experiment design that effectively simulates the optimisation of pipeline specifications by individuals or collectives of researchers using cross validation with limited data. Our findings indicate that bias can plausibly account for an appreciable fraction (often greater than half of the apparent performance improvement associated with the pipeline optimisation, particularly in small samples. We discuss the consistency of our findings with patterns observed in the literature and consider strategies for bias reduction and mitigation.

  12. Improvement of stability of sinusoidally driven atmospheric pressure plasma jet using auxiliary bias voltage

    Directory of Open Access Journals (Sweden)

    Hyun-Jin Kim

    2015-12-01

    Full Text Available In this study, we have proposed the auxiliary bias pulse scheme to improve the stability of atmospheric pressure plasma jets driven by an AC sinusoidal waveform excitation source. The stability of discharges can be significantly improved by the compensation of irregular variation in memory voltage due to the effect of auxiliary bias pulse. From the parametric study, such as the width, voltage, and onset time of auxiliary bias pulse, it has been demonstrated that the auxiliary bias pulse plays a significant role in suppressing the irregular discharges caused by the irregular variation in memory voltage and stable discharge can be initiated with the termination of the auxiliary bias pulse. As a result of further investigating the effects of the auxiliary pulse scheme on the jet stability under various process conditions such as the distance between the jet head and the counter electrode, and carrier gas flow, the jet stability can be improved by adjusting the amplitude and number of the bias pulse depending on the variations in the process conditions.

  13. Removal of arsenic from drinking water by the electrocoagulation using Fe and Al electrodes

    International Nuclear Information System (INIS)

    Kobya, M.; Gebologlu, U.; Ulu, F.; Oncel, S.; Demirbas, E.

    2011-01-01

    Highlights: → Removal percentages of arsenic from drinking water at optimum operating conditions in electrocoagulation process were 93.5% for Fe electrode and 95.7% for Al electrode. → Operating costs at the optimum conditions were 0.020 Euro m -3 for Fe and 0.017 Euro m -3 for Al electrodes. → Surface topography of the solid particles at Fe/Al electrodes was analyzed with scanning electron microscope. → The adsorption of arsenic followed pseudo second-order adsorption model. - Abstract: A novel technique of electrocoagulation (EC) was attempted in the present investigation to remove arsenic from drinking waters. Experiments were carried out in a batch electrochemical reactor using Al and Fe electrodes with monopolar parallel electrode connection mode to assess their efficiency. The effects of several operating parameters on arsenic removal such as pH (4-9), current density (2.5-7.5 A m -2 ), initial concentration (75-500 μg L -1 ) and operating time (0-15 min) were examined. Optimum operating conditions were determined as an operating time of 12.5 min and pH 6.5 for Fe electrode (93.5%) and 15 min and pH 7 for Al electrode (95.7%) at 2.5 A m -2 , respectively. Arsenic removal obtained was highest with Al electrodes. Operating costs at the optimum conditions were calculated as 0.020 Euro m -3 for Fe and 0.017 Euro m -3 for Al electrodes. EC was able to bring down aqueous phase arsenic concentration to less than 10 μg L -1 with Fe and Al electrodes. The adsorption of arsenic over electrochemically produced hydroxides and metal oxide complexes was found to follow pseudo second-order adsorption model. Scanning electron microscopy was also used to analyze surface topography of the solid particles at Fe/Al electrodes during the EC process.

  14. Effects of sertraline, duloxetine, vortioxetine, and idazoxan in the rat affective bias test

    DEFF Research Database (Denmark)

    Refsgaard, Louise Konradsen; Haubro, Kia; Pickering, Darryl S

    2016-01-01

    Rationale Affective biases seemingly play a crucial role for the onset and development of depression. Acute treatment with monoamine-based antidepressants positively influence emotional processing, and an early correction of biases likely results in repeated positive experiences that ultimately...... lead to improved mood. Objectives Using two conventional antidepressants, sertraline and duloxetine, we aimed to forward the characterization of a newly developed affective bias test (ABT) for rats. Further, we examined the effect of vortioxetine, a recently approved antidepressant, and the α2...... adrenoceptor antagonist idazoxan on affective biases....

  15. An experimental verification of laser-velocimeter sampling bias and its correction

    Science.gov (United States)

    Johnson, D. A.; Modarress, D.; Owen, F. K.

    1982-01-01

    The existence of 'sampling bias' in individual-realization laser velocimeter measurements is experimentally verified and shown to be independent of sample rate. The experiments were performed in a simple two-stream mixing shear flow with the standard for comparison being laser-velocimeter results obtained under continuous-wave conditions. It is also demonstrated that the errors resulting from sampling bias can be removed by a proper interpretation of the sampling statistics. In addition, data obtained in a shock-induced separated flow and in the near-wake of airfoils are presented, both bias-corrected and uncorrected, to illustrate the effects of sampling bias in the extreme.

  16. Depositing bulk or micro-scale electrodes

    Science.gov (United States)

    Shah, Kedar G.; Pannu, Satinderpall S.; Tolosa, Vanessa; Tooker, Angela C.; Sheth, Heeral J.; Felix, Sarah H.; Delima, Terri L.

    2016-11-01

    Thicker electrodes are provided on microelectronic device using thermo-compression bonding. A thin-film electrical conducting layer forms electrical conduits and bulk depositing provides an electrode layer on the thin-film electrical conducting layer. An insulating polymer layer encapsulates the electrically thin-film electrical conducting layer and the electrode layer. Some of the insulating layer is removed to expose the electrode layer.

  17. Detection of EEG electrodes in brain volumes.

    Science.gov (United States)

    Graffigna, Juan P; Gómez, M Eugenia; Bustos, José J

    2010-01-01

    This paper presents a method to detect 128 EEG electrodes in image study and to merge with the Nuclear Magnetic Resonance volume for better diagnosis. First we propose three hypotheses to define a specific acquisition protocol in order to recognize the electrodes and to avoid distortions in the image. In the second instance we describe a method for segmenting the electrodes. Finally, registration is performed between volume of the electrodes and NMR.

  18. Recovery of fluoride ion selective electrode

    International Nuclear Information System (INIS)

    Monteiro, R.P.G.

    1988-01-01

    A recovery procedure of fluoride ion selective electrode based upon the body radiography of inactive electrode and introduction of suitable internal regeneration solution, is developed. The recovered electrode was tested in standard solutions of fluoride ions (10 sup5) to 10 -1M showing as good performance as the new one. The fluor determination by potentiometric measurements with selective electrode is used in nuclear fuel cycle for quality control of thorium and uranium mixed oxide pellets and pellets of uranium dioxides. (author) [pt

  19. Alkali metal ion battery with bimetallic electrode

    Science.gov (United States)

    Boysen, Dane A; Bradwell, David J; Jiang, Kai; Kim, Hojong; Ortiz, Luis A; Sadoway, Donald R; Tomaszowska, Alina A; Wei, Weifeng; Wang, Kangli

    2015-04-07

    Electrochemical cells having molten electrodes having an alkali metal provide receipt and delivery of power by transporting atoms of the alkali metal between electrode environments of disparate chemical potentials through an electrochemical pathway comprising a salt of the alkali metal. The chemical potential of the alkali metal is decreased when combined with one or more non-alkali metals, thus producing a voltage between an electrode comprising the molten the alkali metal and the electrode comprising the combined alkali/non-alkali metals.

  20. A Variational Approach to Simultaneous Image Segmentation and Bias Correction.

    Science.gov (United States)

    Zhang, Kaihua; Liu, Qingshan; Song, Huihui; Li, Xuelong

    2015-08-01

    This paper presents a novel variational approach for simultaneous estimation of bias field and segmentation of images with intensity inhomogeneity. We model intensity of inhomogeneous objects to be Gaussian distributed with different means and variances, and then introduce a sliding window to map the original image intensity onto another domain, where the intensity distribution of each object is still Gaussian but can be better separated. The means of the Gaussian distributions in the transformed domain can be adaptively estimated by multiplying the bias field with a piecewise constant signal within the sliding window. A maximum likelihood energy functional is then defined on each local region, which combines the bias field, the membership function of the object region, and the constant approximating the true signal from its corresponding object. The energy functional is then extended to the whole image domain by the Bayesian learning approach. An efficient iterative algorithm is proposed for energy minimization, via which the image segmentation and bias field correction are simultaneously achieved. Furthermore, the smoothness of the obtained optimal bias field is ensured by the normalized convolutions without extra cost. Experiments on real images demonstrated the superiority of the proposed algorithm to other state-of-the-art representative methods.