WorldWideScience

Sample records for bi-ventricular assist device

  1. Left Ventricular Assist Devices

    Directory of Open Access Journals (Sweden)

    Khuansiri Narajeenron

    2017-04-01

    Full Text Available Audience: The audience for this classic team-based learning (cTBL session is emergency medicine residents, faculty, and students; although this topic is applicable to internal medicine and family medicine residents. Introduction: A left ventricular assist device (LVAD is a mechanical circulatory support device that can be placed in critically-ill patients who have poor left ventricular function. After LVAD implantation, patients have improved quality of life.1 The number of LVAD patients worldwide continues to rise. Left-ventricular assist device patients may present to the emergency department (ED with severe, life-threatening conditions. It is essential that emergency physicians have a good understanding of LVADs and their complications. Objectives: Upon completion of this cTBL module, the learner will be able to: 1 Properly assess LVAD patients’ circulatory status; 2 appropriately resuscitate LVAD patients; 3 identify common LVAD complications; 4 evaluate and appropriately manage patients with LVAD malfunctions. Method: The method for this didactic session is cTBL.

  2. Cerebrovascular accidents in patients with a ventricular assist device.

    Science.gov (United States)

    Tsukui, Hiroyuki; Abla, Adib; Teuteberg, Jeffrey J; McNamara, Dennis M; Mathier, Michael A; Cadaret, Linda M; Kormos, Robert L

    2007-07-01

    A cerebrovascular accident is a devastating adverse event in a patient with a ventricular assist device. The goal was to clarify the risk factors for cerebrovascular accident. Prospectively collected data, including medical history, ventricular assist device type, white blood cell count, thrombelastogram, and infection, were reviewed retrospectively in 124 patients. Thirty-one patients (25%) had 48 cerebrovascular accidents. The mean ventricular assist device support period was 228 and 89 days in patients with and without cerebrovascular accidents, respectively (P cerebrovascular accidents occurred within 4 months after implantation. Actuarial freedom from cerebrovascular accident at 6 months was 75%, 64%, 63%, and 33% with the HeartMate device (Thoratec Corp, Pleasanton, Calif), Thoratec biventricular ventricular assist device (Thoratec Corp), Thoratec left ventricular assist device (Thoratec), and Novacor device (WorldHeart, Oakland, Calif), respectively. Twenty cerebrovascular accidents (42%) occurred in patients with infections. The mean white blood cell count at the cerebrovascular accident was greater than the normal range in patients with infection (12,900/mm3) and without infection (9500/mm3). The mean maximum amplitude of the thrombelastogram in the presence of infection (63.6 mm) was higher than that in the absence of infection (60.7 mm) (P = .0309). The risk of cerebrovascular accident increases with a longer ventricular assist device support period. Infection may activate platelet function and predispose the patient to a cerebrovascular accident. An elevation of the white blood cell count may also exacerbate the risk of cerebrovascular accident even in patients without infection. Selection of device type, prevention of infection, and meticulous control of anticoagulation are key to preventing cerebrovascular accident.

  3. High pulmonary vascular resistance in addition to low right ventricular stroke work index effectively predicts biventricular assist device requirement.

    Science.gov (United States)

    Imamura, Teruhiko; Kinugawa, Koichiro; Kinoshita, Osamu; Nawata, Kan; Ono, Minoru

    2016-03-01

    Although the right ventricular stroke work index (RVSWI) is a good index for RV function, a low RVSWI is not necessarily an indicator for the need for a right ventricular assist device at the time of left VAD implantation. We here aimed to determine a more precise indicator for the need for a biventricular assist device (BiVAD). In total, 116 patients (mean age, 38 ± 14 years), who underwent hemodynamic assessments preoperatively including 12 BiVAD patients, and had been followed at our institute from 2003 to 2015, were included. Multivariate logistic regression analysis indicated that RVSWI and pulmonary vascular resistance (PVR) were independent predictors of BiVAD requirement (P 5 g/m, PVR 5, PVR > 3.7), (3) RV failure (RVSWI 3.7), and examined. Most of the patients in Group 4 (75 %), with acutely depressed hemodynamics and inflammatory responses in the myocardium, required BiVAD. Overall, patients with BiVAD had a worse survival rate as compared with those with LVAD alone. In conclusion, high PVR in addition to low RVSWI effectively predicts BiVAD requirement.

  4. Ethical challenges with the left ventricular assist device as a destination therapy

    Directory of Open Access Journals (Sweden)

    Rady Mohamed Y

    2008-08-01

    Full Text Available Abstract The left ventricular assist device was originally designed to be surgically implanted as a bridge to transplantation for patients with chronic end-stage heart failure. On the basis of the REMATCH trial, the US Food and Drug Administration and the US Centers for Medicare & Medicaid Services approved permanent implantation of the left ventricular assist device as a destination therapy in Medicare beneficiaries who are not candidates for heart transplantation. The use of the left ventricular assist device as a destination therapy raises certain ethical challenges. Left ventricular assist devices can prolong the survival of average recipients compared with optimal medical management of chronic end-stage heart failure. However, the overall quality of life can be adversely affected in some recipients because of serious infections, neurologic complications, and device malfunction. Left ventricular assist devices alter end-of-life trajectories. The caregivers of recipients may experience significant burden (e.g., poor physical health, depression, anxiety, and posttraumatic stress disorder from destination therapy with left ventricular assist devices. There are also social and financial ramifications for recipients and their families. We advocate early utilization of a palliative care approach and outline prerequisite conditions so that consenting for the use of a left ventricular assist device as a destination therapy is a well informed process. These conditions include: (1 direct participation of a multidisciplinary care team, including palliative care specialists, (2 a concise plan of care for anticipated device-related complications, (3 careful surveillance and counseling for caregiver burden, (4 advance-care planning for anticipated end-of-life trajectories and timing of device deactivation, and (5 a plan to address the long-term financial burden on patients, families, and caregivers. Short-term mechanical circulatory devices (e

  5. Analysis of Contemporary Methods for Designing Rotary Type Ventricular Assist Devices

    Directory of Open Access Journals (Sweden)

    E. P. Banin

    2015-01-01

    Full Text Available The research object is inlet apparatus of ventricular assist device, namely inlet cannula and straightener.The purpose of the study is to reveal features of blood flow in inlet apparatus of ventricular assist device. The mathematical modeling is carried out by computational fluid dynamics analysis in a stationary setting.The first part of study concerns the analysis of existing approaches to the numerical and experimental studies in designing the ventricular assist devices of rotary type. It reveals the features of each approach for their further application in practice. The article presents an original design of developed hydraulic test bench to verify the results of mathematical modeling. Analysis of foreign authors’ studies showed that there is no enough attention paid to design of the adjacent pump assemblies of ventricular assist device. The second part of study considers direct mathematical modeling of input apparatus of ventricular assist device. The study examined straightener with three or four blades. Mathematical modeling has revealed the presence of potentially dangerous stagnation zones and essential asymmetry of the outlet flow from the input unit. The found features must be taken in consideration in designing the ventricular assist device pumps. In the future we plan to use obtained data to create a parametric model of the rotor and the diffuser considering the abovementioned features.

  6. A novel implantable electromechanical ventricular assist device - First acute animal testing

    NARCIS (Netherlands)

    Kaufmann, R; Rakhorst, G; Mihaylov, D; Elstrodt, J; Nix, C; Reul, H; Rau, G

    1997-01-01

    A novel ventricular assist device (HIA-EMLVAD-AT1, Helmholtz Institute Aachen-electromechanical Left Ventricular Assist Device-Animal Test Version 1), driven by a uniformly and unidirectionally rotating actuator and a patented hypocycloidic pusherplate displacement gear unit, was developed and

  7. Percutaneous Repair of Postoperative Mitral Regurgitation After Left Ventricular Assist Device Implant.

    Science.gov (United States)

    Cork, David P; Adamson, Robert; Gollapudi, Raghava; Dembitsky, Walter; Jaski, Brian

    2018-02-01

    Mitral regurgitation commonly improves after implantation of a left ventricular assist device without concomitant valvular repair owing to the mechanical unloading of the left ventricle. However, the development (or persistence) of significant mitral regurgitation after implantation of a left ventricular assist device is associated with adverse clinical events. We present a case of a left ventricular assist device patient who successfully underwent a percutaneous MitraClip procedure for repair of persistent late postoperative mitral insufficiency with demonstrable clinical and hemodynamic improvement. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  8. Right ventricular failure after implantation of a continuous-flow left ventricular assist device

    DEFF Research Database (Denmark)

    Cordtz, Johan Joakim; Nilsson, Jens C; Hansen, Peter B

    2014-01-01

    Right ventricular failure (RVF) is a significant complication after implantation of a left ventricular assist device. We aimed to identify haemodynamic changes in the early postoperative phase that predicted subsequent development of RVF in a cohort of HeartMate II (HMII) implanted patients....

  9. Comparison of Transplant Waitlist Outcomes for Pediatric Candidates Supported by Ventricular Assist Devices Versus Medical Therapy.

    Science.gov (United States)

    Law, Sabrina P; Oron, Assaf P; Kemna, Mariska S; Albers, Erin L; McMullan, D Michael; Chen, Jonathan M; Law, Yuk M

    2018-05-01

    Ventricular assist devices have gained popularity in the management of refractory heart failure in children listed for heart transplantation. Our primary aim was to compare the composite endpoint of all-cause pretransplant mortality and loss of transplant eligibility in children who were treated with a ventricular assist device versus a medically managed cohort. This was a retrospective cohort analysis. Data were obtained from the Scientific Registry of Transplant Recipients. The at-risk population (n = 1,380) was less than 18 years old, either on a ventricular assist device (605 cases) or an equivalent-severity, intensively medically treated group (referred to as MED, 775 cases). None. The impact of ventricular assist devices was estimated via Cox proportional hazards regression (hazard ratio), dichotomizing 1-year outcomes to "poor" (22%: 193 deaths, 114 too sick) versus all others (940 successful transplants, 41 too healthy, 90 censored), while adjusting for conventional risk factors. Among children 0-12 months old, ventricular assist device was associated with a higher risk of poor outcomes (hazard ratio, 2.1; 95% CI, 1.5-3.0; p comparative study of ventricular assist devices versus medical therapy in children. Age is a significant modulator of waitlist outcomes for children with end-stage heart failure supported by ventricular assist device, with the impact of ventricular assist devices being more beneficial in adolescents.

  10. Ethical Analysis of Withdrawing Ventricular Assist Device Support

    OpenAIRE

    Mueller, Paul S.; Swetz, Keith M.; Freeman, Monica R.; Carter, Kari A.; Crowley, Mary Eliot; Severson, Cathy J. Anderson; Park, Soon J.; Sulmasy, Daniel P.

    2010-01-01

    OBJECTIVE: To describe a series of patients with heart failure supported with a ventricular assist device (VAD) who requested (or whose surrogates requested) withdrawal of VAD support and the legal and ethical aspects pertaining to these requests.

  11. Durability of central aortic valve closure in patients with continuous flow left ventricular assist devices.

    Science.gov (United States)

    McKellar, Stephen H; Deo, Salil; Daly, Richard C; Durham, Lucian A; Joyce, Lyle D; Stulak, John M; Park, Soon J

    2014-01-01

    A competent aortic valve is essential to providing effective left ventricular assist device support. We have adopted a practice of central aortic valve closure by placing a simple coaptation stitch at left ventricular assist device implantation in patients with significant aortic insufficiency. We conducted a follow-up study to evaluate the efficacy and durability of this procedure. The study included patients who had undergone continuous flow left ventricular assist device implantation. The patients were divided into 2 groups, those who did not require any aortic procedure because the valve was competent and those who underwent central aortic valve closure for mild or greater aortic regurgitation. The clinical endpoints were mortality, progression or recurrence of aortic insufficiency, and reoperation for aortic valve pathologic features. Aortic insufficiency was measured qualitatively from mild to severe on a scale of 0 to 5. A total of 123 patients received continuous flow left ventricular assist devices from February 2007 to August 2011. Of those, 18 (15%) underwent central aortic valve closure at left ventricular assist device implantation because of significant aortic insufficiency (1.8 ± 1.4) and 105 who did not (competent aortic valve, 0.15 ± 0.43; P assist device-supported patients, with follow-up extending into 2 years. Although aortic insufficiency progressed over time in those with minimal native valve regurgitation initially, no such progression was noted in those with central aortic valve closure. Additional investigation is needed to evaluate whether prophylactic central aortic valve closure should be performed at left ventricular assist device implantation to avoid problematic aortic regurgitation developing over time, in particular in patients undergoing left ventricular assist device implantation for life-long (destination therapy) support. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights

  12. Management of severe ischemic cardiomyopathy: left ventricular assist device as destination therapy versus conventional bypass and mitral valve surgery.

    Science.gov (United States)

    Maltais, Simon; Tchantchaleishvili, Vahtang; Schaff, Hartzell V; Daly, Richard C; Suri, Rakesh M; Dearani, Joseph A; Topilsky, Yan; Stulak, John M; Joyce, Lyle D; Park, Soon J

    2014-04-01

    Patients with severe ischemic cardiomyopathy (left ventricular ejection fraction assist device as destination therapy is reserved for patients who are too high risk for conventional surgery. We evaluated our outcomes with conventional surgery within this population and the comparative effectiveness of these 2 therapies. We identified patients who underwent conventional surgery or left ventricular assist device as destination therapy for severe ischemic cardiomyopathy (left ventricular ejection fraction assist device as destination therapy. We compared baseline patient characteristics and outcomes in terms of end-organ function and survival. A total of 88 patients were identified; 55 patients underwent conventional surgery (63%), and 33 patients (37%) received a left ventricular assist device as destination therapy. Patients who received left ventricular assist device as destination therapy had the increased prevalence of renal failure, inotrope dependency, and intra-aortic balloon support. Patients undergoing conventional surgery required longer ventilatory support, and patients receiving a left ventricular assist device required more reoperation for bleeding. Mortality rates were similar between the 2 groups at 30 days (7% in the conventional surgery group vs 3% in the left ventricular assist device as destination therapy group, P = .65) and at 1 year (22% in the conventional surgery group vs 15% in the left ventricular assist device as destination therapy group, P = .58). There was a trend toward improved survival in patients receiving a left ventricular assist device compared with the propensity-matched groups at 1 year (94% vs 71%, P = .171). The operative mortality and early survival after conventional surgery seem to be acceptable. For inoperable or prohibitive-risk patients, left ventricular assist device as destination therapy can be offered with similar outcomes. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby

  13. Mycobacterium chimaera left ventricular assist device infections.

    Science.gov (United States)

    Balsam, Leora B; Louie, Eddie; Hill, Fred; Levine, Jamie; Phillips, Michael S

    2017-06-01

    A global outbreak of invasive Mycobacterium chimaera infections after cardiac surgery has recently been linked to bioaerosols from contaminated heater-cooler units. The majority of cases have occurred after valvular surgery or aortic graft surgery and nearly half have resulted in death. To date, infections in patients with left ventricular assist devices (LVADs) have not been characterized in the literature. We report two cases of device-associated M. chimaera infection in patients with continuous-flow LVADs and describe challenges related to diagnosis and management in this population. © 2017 Wiley Periodicals, Inc.

  14. COST-EFFECTIVENESS OF CONTINUOUS-FLOW LEFT VENTRICULAR ASSIST DEVICES

    NARCIS (Netherlands)

    Neyt, Mattias; Van den Bruel, Ann; Smit, Yolba; De Jonge, Nicolaas; Erasmus, Michiel; Van Dijk, Diederik; Vlayen, Joan

    Objectives: Mechanical circulatory support through left ventricular assist devices (LVADs) improves survival and quality of life for patients with end-stage heart failure who are ineligible for cardiac transplantation. Our aim was to calculate the cost-effectiveness of continuous-flow LVADs.

  15. Association of HeartMate II left ventricular assist device flow estimate with thermodilution cardiac output.

    Science.gov (United States)

    Hasin, Tal; Huebner, Marianne; Li, Zhuo; Brown, Daniel; Stulak, John M; Boilson, Barry A; Joyce, Lyle; Pereira, Naveen L; Kushwaha, Sudhir S; Park, Soon J

    2014-01-01

    Cardiac output (CO) assessment is important in treating patients with heart failure. Durable left ventricular assist devices (LVADs) provide essentially all CO. In currently used LVADs, estimated device flow is generated by a computerized algorithm. However, LVAD flow estimate may be inaccurate in tracking true CO. We correlated LVAD (HeartMate II) flow with thermodilution CO during postoperative care (day 2-10 after implant) in 81 patients (5,616 paired measurements). Left ventricular assist device flow and CO correlated with a low correlation coefficient (r = 0.42). Left ventricular assist device readings were lower than CO measurements by approximately 0.36 L/min, trending for larger difference with higher values. Left ventricular assist device flow measurements showed less temporal variability compared with CO. Grouping for simultaneous measured blood pressure (BP device flow generally trends with measured CO, but large variability exists, hence flow measures should not be assumed to equal with CO. Clinicians should take into account variables such as high CO, BP, and opening of the aortic valve when interpreting LVAD flow readout. Direct flow sensors incorporated in the LVAD system may allow for better estimation.

  16. Left Ventricular Assist Devices: The Adolescence of a Disruptive Technology.

    Science.gov (United States)

    Pinney, Sean P

    2015-10-01

    Clinical outcomes for patients with advanced heart failure receiving left ventricular assist devices are driven by appropriate patient selection, refined surgical technique, and coordinated medical care. Perhaps even more important is innovative pump design. The introduction and widespread adoption of continuous-flow ventricular assist devices has led to a paradigm shift within the field of mechanical circulatory support, making the promise of lifetime device therapy closer to reality. The disruption caused by this new technology, on the one hand, produced meaningful improvements in patient survival and quality of life, but also introduced new clinical challenges, such as bleeding, pump thrombosis, and acquired valvular heart disease. Further evolution within this field will require financial investment to sustain innovation leading to a fully implantable, durable, and cost-effective pump for a larger segment of patients with advanced heart failure. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. Inhaled Milrinone After Left Ventricular Assist Device Implantation.

    Science.gov (United States)

    Haglund, Nicholas A; Burdorf, Adam; Jones, Tara; Shostrom, Valerie; Um, John; Ryan, Timothy; Shillcutt, Sasha; Fischer, Patricia; Cox, Zachary L; Raichlin, Eugenia; Anderson, Daniel R; Lowes, Brian D; Dumitru, Ioana

    2015-10-01

    Proven strategies to reduce right ventricular (RV) dysfunction after continuous-flow left ventricular assist device (CF-LVAD) implantation are lacking. We sought to evaluate the tolerability, feasibility, efficacy, and pharmacokinetics of inhaled milrinone (iMil) delivery after CF-LVAD implantation. We prospectively evaluated fixed-dose nebulized iMil delivered into a ventilator circuit for 24 hours in 10 postoperative CF-LVAD (Heartmate-II) patients. Tolerability (arrhythmias, hypotension, and hypersensitivity reaction), efficacy (hemodynamics), pharmacokinetics (plasma milrinone levels), and cost data were collected.Mean age was 56 ± 9 years, 90% were male, and mean INTERMACS profile was 2.5 ± 0.8. No new atrial arrhythmia events occurred, although 3 (30%) ventricular tachycardia (1 nonsustained, 2 sustained) events occurred. Sustained hypotension, drug hypersensitivity, death, or need for right ventricular assist device were not observed. Invasive mean pulmonary arterial pressure from baseline to during iMil therapy was improved (P = .017). Mean plasma milrinone levels (ng/mL) at baseline, and 1, 4, 8, 12, and 24 hours were 74.2 ± 35.4, 111.3 ± 70.9, 135.9 ± 41.5, 205.0 ± 86.7, 176.8 ± 61.3 187.6 ± 105.5, respectively. Reduced institutional cost was observed when iMil was compared with nitric oxide therapy over 24 hours ($165.29 vs $1,944.00, respectively). iMil delivery after CF-LVAD implantation was well tolerated, feasible, and demonstrated favorable hemodynamic, pharmacokinetic, and cost profiles. iMil therapy warrants further study in larger clinical trials. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. The Achilles' heel of left ventricular assist device therapy: right ventricle.

    Science.gov (United States)

    Ranganath, Neel K; Smith, Deane E; Moazami, Nader

    2018-06-01

    Many patients suffer from either persistent right ventricular failure (RVF) at the time of left ventricular assist device (LVAD) or have ongoing symptoms consistent with RVF during chronic mechanical circulatory support. The lack of long-term right ventricular assist devices (RVADs) has limited the impact that mechanical circulatory support can provide to patients with biventricular failure. We aim to review the entire spectrum of RVF in patients receiving LVADs and reflect on why this entity remains the Achilles' heel of LVAD therapy. In the early postoperative period, LVAD implantation reduces right ventricle (RV) afterload, but RV dysfunction may be exacerbated secondary to increased venous return. With prolonged therapy, the decreased RV afterload leads to improved RV contractile function. Bayesian statistical models outperform previously published preoperative risk scores by considering inter-relationships and conditional probabilities amongst independent variables. Various echocardiographic parameters and the pulmonary artery pulsatility index have shown promise in predicting post-LVAD RVF. Recent publications have delineated the emergence of 'delayed' RVF. Several devices are currently being investigated for use as RVADs. Post-LVAD RVF depends on the RV's ability to adapt to acute hemodynamic changes imposed by the LVAD. Management options are limited due to the lack of an easily implantable, chronic-use RVAD.

  19. Our experience with implantation of VentrAssist left ventricular assist device

    Directory of Open Access Journals (Sweden)

    Hiriyur Shivalingappa Jayanthkumar

    2013-01-01

    Full Text Available Perioperative anaesthetic management of the VentrAssist TM left ventricular assist device (LVAD is a challenge for anaesthesiologists because patients presenting for this operation have long-standing cardiac failure and often have associated hepatic and renal impairment, which may significantly alter the pharmacokinetics of administered drugs and render the patients coagulopathic. The VentrAssist is implanted by midline sternotomy. A brief period of cardiopulmonary bypass (CPB for apical cannulation of left ventricle is needed. The centrifugal pump, which produces non-pulsatile, continuous flow, is positioned in the left sub-diaphragmatic pocket. This LVAD is preload dependent and afterload sensitive. Transoesophageal echocardiography is an essential tool to rule out contraindications and to ensure proper inflow cannula position, and following the implantation of LVAD, to ensure right ventricular (RV function. The anaesthesiologist should be prepared to manage cardiac decompensation and acute desaturation before initiation of CPB, as well as RV failure and severe coagulopathic bleeding after CPB. Three patients had undergone implantation of VentrAssist in our hospital. This pump provides flow of 5 l/min depending on preload, afterload and pump speed. All the patients were discharged after an average of 30 days. There was no perioperative mortality.

  20. Intraoperative bronchoscopic visualization of left ventricular assist device thrombus.

    Science.gov (United States)

    Yost, Gardner; Bhat, Geetha; Modi, Sejal; Pappas, Pat; Tatooles, Antone

    2016-07-01

    Despite advancements in left ventricular assist device (LVAD) design and clinical management, device thrombosis remains a pertinent complication. Limited imaging makes precise visualization of clot location and shape very challenging. We report the usage of videobronchoscopic exploration of explanted LVADs for direct visualization of clot in two patients. This technique is a rapid and inexpensive means of improving our understanding of LVAD clot formation and may be useful in surgical exploration of inflow and outflow tracts during LVAD exchange. © The Author(s) 2015.

  1. Perioperative management of calves undergoing implantation of a left ventricular assist device.

    Science.gov (United States)

    Wilson, D V; Kantrowitz, A; Pacholewicz, J; Salat, O; Paules, B R; Zhou, Y; Dawe, E J

    2000-01-01

    To describe perioperative management of calves that underwent left lateral thoracotomy, aortic cross-clamping, partial left heart bypass and implantation of a left ventricular assist device. A total of 43 healthy castrated male calves, weighing 121 +/- 24 kg. Diazepam (mean +/- SD, 0.26 +/- 0.07 mg/kg), ketamine (5.9 +/- 2.17 mg/kg) and isoflurane were used in the anesthetic management of calves undergoing implantation of a left ventricular assist device in the descending thoracic aorta. Other adjunctive agents administered were fentanyl (11 +/- 5.4 microg/kg), lidocaine (4.9 +/- 3.19 mg/kg), bupivacaine (0.75%) and butorphanol (0.49 +/- 0.13 mg/kg). None of the calves regurgitated at induction or during intubation. A tube was used to drain the rumen and prevent bloat during the procedure. Partial left heart bypass was used to perfuse the caudal half of the body during the period of aortic cross clamp and device implantation. Initial mean systemic blood pressure was 96 +/- 25 mm Hg, and pressures measured in the auricular artery increased during aortic cross-clamping and bypass. Vasoconstrictor therapy was required to treat caudal arterial hypotension during the procedure in 9 calves. Mean systemic arterial pressures returned to baseline values by the end of the anesthetic period. Initial mean pulmonary arterial pressures (PAP) were 22 +/- 3 mm Hg. A significant but transient increase in pulmonary arterial pressure occurred after both heparin and protamine administration. The described anesthetic protocol was effective for thoracotomy and implantation of an intra-aortic left ventricular assist device in normal calves. Partial left ventricular bypass was a useful adjunct during the period of aortic cross clamp. The doses of heparin and protamine administered were effective. Responsibility to monitor oxygenation of the cranial half of the animal continues during the bypass period as hypoxemia due to pulmonary dysfunction will not be detected by the perfusionist.

  2. Outcomes of patients with right ventricular failure on milrinone after left ventricular assist device implantation.

    Science.gov (United States)

    Tsiouris, Athanasios; Paone, Gaetano; Brewer, Robert J; Nemeh, Hassan W; Borgi, Jamil; Morgan, Jeffrey A

    2015-01-01

    Previous studies have grouped together both patients requiring right ventricular assist devices (RVADs) with patients requiring prolonged milrinone therapy after left ventricular assist device (LVAD) implantation. We retrospectively identified 149 patients receiving LVADs and 18 (12.1%) of which developed right ventricular (RV) failure. We then separated these patients into those requiring RVADs versus prolonged milrinone therapy. This included 10 patients who were treated with prolonged milrinone and eight patients who underwent RVAD placement. Overall, the RV failure group had worse survival compared with the non-RV failure cohort (p = 0.038). However, this was only for the subgroup of patients who required RVADs, who had a 1, 6, 12, and 24 month survival of 62.5%, 37.5%, 37.5%, and 37.5%, respectively, versus 96.8%, 92.1%, 86.7%, and 84.4% for patients without RV failure (p milrinone therapy for RV failure had similar survivals compared with patients without RV failure. In the RV failure group, age, preoperative renal failure, and previous cardiac surgery were predictors of the need for prolonged postoperative milrinone. As LVADs become a more widely used therapy for patients with refractory, end-stage heart failure, it will be important to reduce the incidence of RV failure, as it yields significant morbidity and increases cost.

  3. Ventricular fibrillation in an ambulatory patient supported by a left ventricular assist device: highlighting the ICD controversy.

    Science.gov (United States)

    Boilson, Barry A; Durham, Lucian A; Park, Soon J

    2012-01-01

    Left ventricular assist devices (LVADs) provide an effective means of managing advanced pump failure as a means of bridging to cardiac transplantation or as permanent therapy. Although ventricular arrhythmias remain common post-LVAD implantation, such therapy may allow malignant arrhythmias to be tolerated hemodynamically. This report describes the clinical findings in a patient who had likely been in a ventricular tachyarrhythmia for several days and presented in ventricular fibrillation, ambulatory, and mentating normally. This report, with previous similar reports, is additive to the body of evidence that LVADs alter the physiologic impact of ventricular arrhythmias in advanced heart failure and highlights the need for thoughtful programming of implantable cardioverter defibrillator therapies in these patients.

  4. Endocarditis in left ventricular assist device

    Science.gov (United States)

    Thyagarajan, Braghadheeswar; Kumar, Monisha Priyadarshini; Sikachi, Rutuja R; Agrawal, Abhinav

    2016-01-01

    Summary Heart failure is one of the leading causes of death in developed nations. End stage heart failure often requires cardiac transplantation for survival. The left ventricular assist device (LVAD) has been one of the biggest evolvements in heart failure management often serving as bridge to transplant or destination therapy in advanced heart failure. Like any other medical device, LVAD is associated with complications with infections being reported in many patients. Endocarditis developing secondary to the placement of LVAD is not a frequent, serious and difficult to treat condition with high morbidity and mortality. Currently, there are few retrospective studies and case reports reporting the same. In our review, we found the most common cause of endocarditis in LVAD was due to bacteria. Both bacterial and fungal endocarditis were associated with high morbidity and mortality. In this review we will be discussing the risk factors, organisms involved, diagnostic tests, management strategies, complications, and outcomes in patients who developed endocarditis secondary to LVAD placement. PMID:27672540

  5. Intraoperative Transesophageal Echocardiography and Right Ventricular Failure After Left Ventricular Assist Device Implantation.

    Science.gov (United States)

    Silverton, Natalie A; Patel, Ravi; Zimmerman, Josh; Ma, Jianing; Stoddard, Greg; Selzman, Craig; Morrissey, Candice K

    2018-02-15

    To determine whether intraoperative measures of right ventricular (RV) function using transesophageal echocardiography are associated with subsequent RV failure after left ventricular assist device (LVAD) implantation. Retrospective, nonrandomized, observational study. Single tertiary-level, university-affiliated hospital. The study comprised 100 patients with systolic heart failure undergoing elective LVAD implantation. Transesophageal echocardiographic images before and after cardiopulmonary bypass were analyzed to quantify RV function using tricuspid annular plane systolic excursion (TAPSE), tricuspid annular systolic velocity (S'), fractional area change (FAC), RV global longitudinal strain, and RV free wall strain. A chart review was performed to determine which patients subsequently developed RV failure (right ventricular assist device placement or prolonged inotrope requirement ≥14 days). Nineteen patients (19%) subsequently developed RV failure. Postbypass FAC was the only measure of RV function that distinguished between the RV failure and non-RV failure groups (21.2% v 26.5%; p = 0.04). The sensitivity, specificity, and area under the curve of an abnormal RV FAC (failure after LVAD implantation were 84%, 20%, and 0.52, respectively. No other intraoperative measure of RV function was associated with subsequent RV failure. RV failure increased ventilator time, intensive care unit and hospital length of stay, and mortality. Intraoperative measures of RV function such as tricuspid annular plane systolic excursion, tricuspid annular systolic velocity, and RV strain were not associated with RV failure after LVAD implantation. Decreased postbypass FAC was significantly associated with RV failure but showed poor discrimination. Copyright © 2018 Elsevier Inc. All rights reserved.

  6. Novel nonsurgical left ventricular assist device and system.

    Science.gov (United States)

    Misiri, Juna; DeSimone, Christopher V; Park, Soon J; Kushwaha, Sudhir S; Friedman, Paul A; Bruce, Charles J; Asirvatham, Samuel J

    2013-01-01

    Treatment options for advanced stages of congestive heart failure remain limited. Left ventricular assist devices (LVADs) have emerged as a means to support failing circulation. However, these devices are not without significant risk such as major open chest surgery. We utilized a novel approach for device placement at the aorto-left atria continuity as a site to create a conduit capable of accommodating a percutaneous LVAD system. We designed and developed an expandable nitinol based device for placement at this site to create a shunt between the LA and aorta. Our experiments support this anatomic location as an accessible and feasible site for accommodation of an entirely percutaneous LVAD. The novelty of this approach would bypass the left ventricle, and thereby minimize complications and morbidities associated with current LVAD placement. Copyright © 2013 Elsevier Inc. All rights reserved.

  7. Ventricular assist device implantation in a young patient with non-compaction cardiomyopathy and hereditary spherocytosis.

    Science.gov (United States)

    Huenges, Katharina; Panholzer, Bernd; Cremer, Jochen; Haneya, Assad

    2018-04-01

    A case of a 15-year-old female patient with acute heart failure due to non-compaction cardiomyopathy and hereditary anaemia (hereditary spherocytic elliptocytosis) requiring ventricular assist device implantation as a bridge to transplantation is presented. The possible effects of mechanical stress on erythrocytes potentially induced by mechanical circulatory support remains unclear, but it may lead to haemolytic crisis in patients suffering from hereditary anaemia. In our case, ventricular assist device therapy was feasible, and haematological complications did not occur within 6 weeks of bridging our patient to heart transplantation.

  8. Right ventricular functional analysis utilizing first pass radionuclide angiography for pre-operative ventricular assist device planning: a multi-modality comparison.

    Science.gov (United States)

    Avery, Ryan; Day, Kevin; Jokerst, Clinton; Kazui, Toshinobu; Krupinski, Elizabeth; Khalpey, Zain

    2017-10-10

    Advanced heart failure treated with a left ventricular assist device is associated with a higher risk of right heart failure. Many advanced heart failures patients are treated with an ICD, a relative contraindication to MRI, prior to assist device placement. Given this limitation, left and right ventricular function for patients with an ICD is calculated using radionuclide angiography utilizing planar multigated acquisition (MUGA) and first pass radionuclide angiography (FPRNA), respectively. Given the availability of MRI protocols that can accommodate patients with ICDs, we have correlated the findings of ventricular functional analysis using radionuclide angiography to cardiac MRI, the reference standard for ventricle function calculation, to directly correlate calculated ejection fractions between these modalities, and to also assess agreement between available echocardiographic and hemodynamic parameters of right ventricular function. A retrospective review from January 2012 through May 2014 was performed to identify advanced heart failure patients who underwent both cardiac MRI and radionuclide angiography for ventricular functional analysis. Nine heart failure patients (8 men, 1 woman; mean age of 57.0 years) were identified. The average time between the cardiac MRI and radionuclide angiography exams was 38.9 days (range: 1 - 119 days). All patients undergoing cardiac MRI were scanned using an institutionally approved protocol for ICD with no device-related complications identified. A retrospective chart review of each patient for cardiomyopathy diagnosis, clinical follow-up, and echocardiogram and right heart catheterization performed during evaluation was also performed. The 9 patients demonstrated a mean left ventricular ejection fraction (LVEF) using cardiac MRI of 20.7% (12 - 40%). Mean LVEF using MUGA was 22.6% (12 - 49%). The mean right ventricular ejection fraction (RVEF) utilizing cardiac MRI was 28.3% (16 - 43%), and the mean RVEF calculated by

  9. Surgical treatment of tricuspid valve insufficiency promotes early reverse remodeling in patients with axial-flow left ventricular assist devices.

    Science.gov (United States)

    Maltais, Simon; Topilsky, Yan; Tchantchaleishvili, Vakhtang; McKellar, Stephen H; Durham, Lucian A; Joyce, Lyle D; Daly, Richard C; Park, Soon J

    2012-06-01

    The HeartMate II (Thoratec Corp, Pleasanton, Calif) continuous-flow left ventricular assist device has emerged as the standard of care for patients with advanced heart failure. The objective of this study was to assess the safety and early effectiveness of concomitant tricuspid valve procedures in patients undergoing implantation of a HeartMate II device. From February 2007 to April 2010, 83 patients underwent HeartMate II left ventricular assist device implantation. Of these, 37 patients had concomitant tricuspid valve procedures (32 repairs, 5 replacements) for severe tricuspid regurgitation. The effects of a tricuspid valve procedure on tricuspid regurgitation and right ventricular remodeling were assessed comparing echocardiographic findings at baseline and 30 days after left ventricular assist device implantation. Overall survival was also compared. Patients undergoing a concomitant tricuspid valve procedure had more tricuspid regurgitation (vena contracta, 5.6 ± 2.1 mm vs 2.9 ± 2.0 mm; P tricuspid regurgitation was worse in patients who underwent left ventricular assist device implantation alone (+18.6%), whereas it improved significantly in patients undergoing a concomitant tricuspid valve procedure (-50.2%) (P = .005). A corresponding significant reduction in right ventricular end-diastolic area (33.6% ± 6.2% vs 30.1% ± 9.7%; P = .03) and a trend toward better right ventricular function (55.5% ± 79.7% vs 35.7% ± 60.5%; P = .28) were noted in patients undergoing a concomitant tricuspid valve procedure. Survival was comparable between the 2 groups. In patients with severe tricuspid regurgitation undergoing left ventricular assist device implantation, a concomitant tricuspid valve procedure effectively reduces tricuspid regurgitation and promotes reverse remodeling of the right ventricle. Copyright © 2012 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  10. The Use of Pediatric Ventricular Assist Devices in Children's Hospitals From 2000 to 2010: Morbidity, Mortality, and Hospital Charges.

    Science.gov (United States)

    Mansfield, Robert T; Lin, Kimberly Y; Zaoutis, Theoklis; Mott, Antonio R; Mohamad, Zeinab; Luan, Xianqun; Kaufman, Beth D; Ravishankar, Chitra; Gaynor, J William; Shaddy, Robert E; Rossano, Joseph W

    2015-07-01

    The use of ventricular assist devices has increased dramatically in adult heart failure patients. However, the overall use, outcome, comorbidities, and resource utilization of ventricular assist devices in pediatric patients have not been well described. We sought to demonstrate that the use of ventricular assist devices in pediatric patients has increased over time and that mortality has decreased. A retrospective study of the Pediatric Health Information System database was performed for patients 20 years old or younger undergoing ventricular assist device placement from 2000 to 2010. None. Four hundred seventy-five pediatric patients were implanted with ventricular assist devices during the study period: 69 in 2000-2003 (era 1), 135 in 2004-2006 (era 2), and 271 in 2007-2010 (era 3). Median age at ventricular assist device implantation was 6.0 years (interquartile range, 0.5-13.8), and the proportion of children who were 1-12 years old increased from 29% in era 1 to 47% in era 3 (p = 0.002). The majority of patients had a diagnosis of cardiomyopathy; this increased from 52% in era 1 to 72% in era 3 (p = 0.003). Comorbidities included arrhythmias (48%), pulmonary hypertension (16%), acute renal failure (34%), cerebrovascular disease (28%), and sepsis/systemic inflammatory response syndrome (34%). Two hundred forty-seven patients (52%) underwent heart transplantation and 327 (69%) survived to hospital discharge. Hospital mortality decreased from 42% in era 1 to 25% in era 3 (p = 0.004). Median hospital length of stay increased (37 d [interquartile range, 12-64 d] in era 1 vs 69 d [interquartile range, 35-130] in era 3; p interquartile range, $227,052-$853,318] in era 1 vs $1,577,983 [interquartile range, $874,463-$2,280,435] in era 3; p < 0.001). Factors associated with increased mortality include age less than 1 year (odds ratio, 2.04; 95% CI, 1.01-3.83), acute renal failure (odds ratio, 2.1; 95% CI, 1.26-3.65), cerebrovascular disease (odds ratio, 2.1; 95% CI, 1

  11. Central-Approach Surgical Repair of Coarctation of the Aorta with a Back-up Left Ventricular Assist Device for an Infant Presenting with Severe Left Ventricular Dysfunction

    Directory of Open Access Journals (Sweden)

    Tae Hoon Kim

    2015-12-01

    Full Text Available A two-month-old infant presented with coarctation of the aorta, severe left ventricular dysfunction, and moderate to severe mitral regurgitation. Through median sternotomy, the aortic arch was repaired under cardiopulmonary bypass and regional cerebral perfusion. The patient was postoperatively supported with a left ventricular assist device for five days. Left ventricular function gradually improved, eventually recovering with the concomitant regression of mitral regurgitation. Prompt surgical repair of coarctation of the aorta is indicated for patients with severe left ventricular dysfunction. A central approach for surgical repair with a back-up left ventricular assist device is a safe and effective treatment strategy for these patients.

  12. Central-Approach Surgical Repair of Coarctation of the Aorta with a Back-up Left Ventricular Assist Device for an Infant Presenting with Severe Left Ventricular Dysfunction.

    Science.gov (United States)

    Kim, Tae Hoon; Shin, Yu Rim; Kim, Young Sam; Kim, Do Jung; Kim, Hyohyun; Shin, Hong Ju; Htut, Aung Thein; Park, Han Ki

    2015-12-01

    A two-month-old infant presented with coarctation of the aorta, severe left ventricular dysfunction, and moderate to severe mitral regurgitation. Through median sternotomy, the aortic arch was repaired under cardiopulmonary bypass and regional cerebral perfusion. The patient was postoperatively supported with a left ventricular assist device for five days. Left ventricular function gradually improved, eventually recovering with the concomitant regression of mitral regurgitation. Prompt surgical repair of coarctation of the aorta is indicated for patients with severe left ventricular dysfunction. A central approach for surgical repair with a back-up left ventricular assist device is a safe and effective treatment strategy for these patients.

  13. De novo development of eosinophilic myocarditis with left ventricular assist device support as bridge to transplant.

    Science.gov (United States)

    Pereira, Naveen L; Park, Soon J; Daly, Richard C; Kushwaha, Sudhir S; Edwards, William D

    2010-10-01

    The de novo development of myocarditis during left ventricular assist device support for dilated cardiomyopathy has not been previously described. We report a case of severe eosinophilic myocarditis associated with the use of leukotriene-receptor antagonist montelukast that developed during left ventricular assist device support accompanied by intra-device thrombus formation that was hemodynamically tolerated and subsequently discovered in the explanted heart. There may be no visible change in cardiac function as assessed by echocardiography, but the diagnosis should be entertained with the development of peripheral eosinophilia. Copyright © 2010 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  14. Left ventricular assist device as destination therapy: application of the payment-by-results approach for the device reimbursement.

    Science.gov (United States)

    Messori, Andrea; Trippoli, Sabrina; Bonacchi, Massimo; Sani, Guido

    2009-08-01

    Value-based methods are increasingly used to reimburse therapeutic innovation, and the payment-by-results approach has been proposed for handling interventions with limited therapeutic evidence. Because most left ventricular assist devices are supported by preliminary efficacy data, we examined the effectiveness data of the HeartMate (Thoratec Corp, Pleasanton, CA) device to explore the application of the payment-by-results approach to these devices and to develop a model for handling reimbursements. According to our model, after establishing the societal economic countervalue for each month of life saved, each patient treated with one such device is associated to the payment of this countervalue for every month of survival lived beyond the final date of estimated life expectancy without left ventricular assist devices. Our base-case analysis, which used the published data of 68 patients who received the HeartMate device, was run with a monthly countervalue of euro 5000, no adjustment for quality of life, and a baseline life expectancy of 150 days without left ventricular assist devices. Sensitivity analysis was aimed at testing the effect of quality of life adjustments and changes in life expectancy without device. In our base-case analysis, the mean total reimbursement per patient was euro 82,426 (range, euro 0 to euro 250,000; N = 68) generated as the sum of monthly payments. This average value was close to the current price of the HeartMate device (euro 75,000). Sensitivity testing showed that the base-case reimbursement of euro 82,426 was little influenced by variations in life expectancy, whereas variations in utility had a more pronounced impact. Our report delineates an innovative procedure for appropriately allocating economic resources in this area of invasive cardiology.

  15. The successful implantation of continuous-flow left ventricular assist device as a destination therapy in Korea: echocardiographic assessment.

    Science.gov (United States)

    Lee, Ga Yeon; Park, Sung-Ji; Kim, Sujin; Choi, Namgyung; Jeong, Dong Seop; Jeon, Eun-Seok; Lee, Young Tak

    2014-01-01

    Left ventricular assist device (LVAD) is a good treatment option for the patients ineligible for cardiac transplantation. Several studies have demonstrated that a ventricular assist device improves the quality of life and prognosis of the patients with end-stage heart failure. A 75-yr-old man debilitated with New York Heart Association (NYHA) functional class III-IV due to severe left ventricular systolic dysfunction received LVAD implantation as a destination therapy. The patient was discharged with improved functional status (NYHA functional class II) after appropriate cardiac rehabilitation and education about how to manage the device and potential emergency situations. This is the first case of successful continuous-flow LVAD implantation as a destination therapy in Korea.

  16. Current Trends in Implantable Left Ventricular Assist Devices

    Directory of Open Access Journals (Sweden)

    Jens Garbade

    2011-01-01

    Full Text Available The shortage of appropriate donor organs and the expanding pool of patients waiting for heart transplantation have led to growing interest in alternative strategies, particularly in mechanical circulatory support. Improved results and the increased applicability and durability with left ventricular assist devices (LVADs have enhanced this treatment option available for end-stage heart failure patients. Moreover, outcome with newer pumps have evolved to destination therapy for such patients. Currently, results using nonpulsatile continuous flow pumps document the evolution in outcomes following destination therapy achieved subsequent to the landmark Randomized Evaluation of Mechanical Assistance for the Treatment of Congestive Heart Failure Trial (REMATCH, as well as the outcome of pulsatile designed second-generation LVADs. This review describes the currently available types of LVADs, their clinical use and outcomes, and focuses on the patient selection process.

  17. Synergy of first principles modelling with predictive control for a biventricular assist device: In silico evaluation study.

    Science.gov (United States)

    Koh, Vivian C A; Yong Kuen Ho; Stevens, Michael C; Salamonsen, Robert F; Lovell, Nigel H; Lim, Einly

    2017-07-01

    Control for dual rotary left ventricular assist devices (LVADs) used as a biventricular assist device (BiVAD) is challenging. If the control system fails, flow imbalance between the systemic and the pulmonary circulations would result, subsequently leading to ventricular suction or pulmonary congestion. With the expectation that advanced control approaches such as model predictive control could address the challenges naturally and effectively, we developed a synergistic first principles model predictive controller (MPC) for the BiVAD. The internal model of the MPC is a simplified state-space model that has been developed and validated in a previous study. A single Frank-Starling (FS) control curve was used to define the target pump flow corresponding to the preload on each side of the heart. The MPC was evaluated in a validated numerical model using three clinical scenarios: blood loss, myocardial recovery, and exercise. Simulation results showed that the MPC was effective in adapting to changes in physiological states without causing ventricular suction or pulmonary congestion. The use of MPC for a BiVAD eliminates the need for two controllers of dual LVADs thus making the task of controller tuning easier.

  18. Verification of a computational cardiovascular system model comparing the hemodynamics of a continuous flow to a synchronous valveless pulsatile flow left ventricular assist device.

    Science.gov (United States)

    Gohean, Jeffrey R; George, Mitchell J; Pate, Thomas D; Kurusz, Mark; Longoria, Raul G; Smalling, Richard W

    2013-01-01

    The purpose of this investigation is to use a computational model to compare a synchronized valveless pulsatile left ventricular assist device with continuous flow left ventricular assist devices at the same level of device flow, and to verify the model with in vivo porcine data. A dynamic system model of the human cardiovascular system was developed to simulate the support of a healthy or failing native heart from a continuous flow left ventricular assist device or a synchronous pulsatile valveless dual-piston positive displacement pump. These results were compared with measurements made during in vivo porcine experiments. Results from the simulation model and from the in vivo counterpart show that the pulsatile pump provides higher cardiac output, left ventricular unloading, cardiac pulsatility, and aortic valve flow as compared with the continuous flow model at the same level of support. The dynamic system model developed for this investigation can effectively simulate human cardiovascular support by a synchronous pulsatile or continuous flow ventricular assist device.

  19. Left ventricular assist device implantation via left thoracotomy: alternative to repeat sternotomy.

    Science.gov (United States)

    Pierson, Richard N; Howser, Renee; Donaldson, Terri; Merrill, Walter H; Dignan, Rebecca J; Drinkwater, Davis C; Christian, Karla G; Butler, Javed; Chomsky, Don; Wilson, John R; Clark, Rick; Davis, Stacy F

    2002-03-01

    Repeat sternotomy for left ventricular assist device insertion may result in injury to the right heart or patent coronary grafts, complicating intraoperative and postoperative management. In 4 critically ill patients, left thoracotomy was used as an alternative to repeat sternotomy. Anastomosis of the outflow conduit to the descending thoracic aorta provided satisfactory hemodynamic support.

  20. The medical physics of ventricular assist devices

    International Nuclear Information System (INIS)

    Wood, Houston G; Throckmorton, Amy L; Untaroiu, Alexandrina; Song Xinwei

    2005-01-01

    Millions of patients, from infants to adults, are diagnosed with congestive heart failure each year all over the world. A limited number of donor hearts available for these patients results in a tremendous demand for alternative, supplemental circulatory support in the form of artificial heart pumps or ventricular assist devices (VADs). The development procedure for such a device requires careful consideration of biophysical factors, such as biocompatibility, haemolysis, thrombosis, implantability, physiologic control feasibility and pump performance. Conventional pump design equations based on Newton's law and computational fluid dynamics (CFD) are readily used for the initial design of VADs. In particular, CFD can be employed to predict the pressure-flow performance, hydraulic efficiencies, flow profile through the pump, stress levels and biophysical factors, such as possible blood cell damage. These computational flow simulations may involve comprehensive steady and transient flow analyses. The transient simulations involve time-varying boundary conditions and virtual modelling of the impeller rotation in the blood pumps. After prototype manufacture, laser flow measurements with sophisticated optics and mock circulatory flow loop testing assist with validation of pump design and identification of irregular flow patterns for optimization. Additionally, acute and chronic animal implants illustrate the blood pump's ability to support life physiologically. These extensive design techniques, coupled with fundamental principles of physics, ensure a reliable and effective VAD for thousands of heart failure patients each year

  1. Noninvasive arterial blood pressure waveforms in patients with continuous-flow left ventricular assist devices

    NARCIS (Netherlands)

    Martina, Jerson R.; Westerhof, Berend E.; de Jonge, Nicolaas; van Goudoever, Jeroen; Westers, Paul; Chamuleau, Steven; van Dijk, Diederik; Rodermans, Ben F. M.; de Mol, Bas A. J. M.; Lahpor, Jaap R.

    2014-01-01

    Arterial blood pressure and echocardiography may provide useful physiological information regarding cardiac support in patients with continuous-flow left ventricular assist devices (cf-LVADs). We investigated the accuracy and characteristics of noninvasive blood pressure during cf-LVAD support.

  2. Early Right Ventricular Assist Device Use in Patients Undergoing Continuous-Flow Left Ventricular Assist Device Implantation: Incidence and Risk Factors From the Interagency Registry for Mechanically Assisted Circulatory Support.

    Science.gov (United States)

    Kiernan, Michael S; Grandin, E Wilson; Brinkley, Marshall; Kapur, Navin K; Pham, Duc Thinh; Ruthazer, Robin; Rame, J Eduardo; Atluri, Pavan; Birati, Edo Y; Oliveira, Guilherme H; Pagani, Francis D; Kirklin, James K; Naftel, David; Kormos, Robert L; Teuteberg, Jeffrey J; DeNofrio, David

    2017-10-01

    To investigate preimplant risk factors associated with early right ventricular assist device (RVAD) use in patients undergoing continuous-flow left ventricular assist device (LVAD) surgery. Patients in the Interagency Registry for Mechanically Assisted Circulatory Support who underwent primary continuous-flow-LVAD surgery were examined for concurrent or subsequent RVAD implantation within 14 days of LVAD. Risk factors for RVAD implantation and the combined end point of RVAD or death within 14 days of LVAD were assessed with stepwise logistic regression. We compared survival between patients with and without RVAD using Kaplan-Meier method and Cox proportional hazards modeling. Of 9976 patients undergoing continuous-flow-LVAD implantation, 386 patients (3.9%) required an RVAD within 14 days of LVAD surgery. Preimplant characteristics associated with RVAD use included interagency registry for mechanically assisted circulatory support patient profiles 1 and 2, the need for preoperative extracorporeal membrane oxygenation or renal replacement therapy, severe preimplant tricuspid regurgitation, history of cardiac surgery, and concomitant procedures other than tricuspid valve repair at the time of LVAD. Hemodynamic determinants included elevated right atrial pressure, reduced pulmonary artery pulse pressure, and reduced stroke volume. The final model demonstrated good performance for both RVAD implant (area under the curve, 0.78) and the combined end point of RVAD or death within 14 days (area under the curve, 0.73). Compared with patients receiving an isolated LVAD, patients requiring RVAD had decreased 1- and 6-month survival: 78.1% versus 95.8% and 63.6% versus 87.9%, respectively ( P The need for RVAD implantation after LVAD is associated with indices of global illness severity, markers of end-organ dysfunction, and profiles of hemodynamic instability. © 2017 American Heart Association, Inc.

  3. Multicenter Evaluation of Octreotide as Secondary Prophylaxis in Patients With Left Ventricular Assist Devices and Gastrointestinal Bleeding.

    Science.gov (United States)

    Shah, Keyur B; Gunda, Sampath; Emani, Sitaramesh; Kanwar, Manreet K; Uriel, Nir; Colombo, Paolo C; Uber, Patricia A; Sears, Melissa L; Chuang, Joyce; Farrar, David J; Brophy, Donald F; Smallfield, George B

    2017-11-01

    Gastrointestinal (GI) bleeding is one of the most common complications after continuous-flow left ventricular assist device implantation. More than one third of patients with incident bleed go on to develop recurrent GI bleeding. Octreotide, a somatostatin analog, is proposed to reduce the risk of recurrent GI bleeding in this population. This multicenter, retrospective analysis evaluated 51 continuous-flow left ventricular assist device patients who received secondary prophylaxis with octreotide after their index GI bleed from 2009 to 2015. All patients had a hospitalization for GI bleed and received octreotide after discharge. Patient demographics, medical and medication history, and clinical characteristics of patients who rebled after receiving octreotide were compared with non-rebleeders. These data were also compared with matched historical control patients previously enrolled in the HMII (HeartMate II) clinical trials, none of whom received octreotide, to provide a context for the bleeding rates. Twelve patients (24%) who received secondary octreotide prophylaxis developed another GI bleed, whereas 39 (76%) did not. There were similar intergroup demographics; however, significantly more bleeders had a previous GI bleeding history before left ventricular assist device placement (33% versus 5%; P =0.02) and greater frequency of angiodysplasia confirmed during endoscopy (58% versus 23%; P =0.03). Fewer patients in this study experienced a recurrent GI bleed compared with a matched historical control group that did not receive octreotide (24% versus 43%; P =0.04). Patients with continuous-flow left ventricular assist device receiving secondary prophylaxis with octreotide had a significantly lower GI bleed recurrence compared with historical controls not treated with octreotide. Additional prospective studies are needed to confirm these data. © 2017 American Heart Association, Inc.

  4. Management issues during HeartWare left ventricular assist device implantation and the role of transesophageal echocardiography

    Directory of Open Access Journals (Sweden)

    Sanjay Orathi Patangi

    2013-01-01

    Full Text Available Left ventricular assist devices (LVAD are increasingly used for mechanical circulatory support of patients with severe heart failure, primarily as a bridge to heart transplantation. Transesophageal echocardiography (TEE plays a major role in the clinical decision making during insertion of the devices and in the post-operative management of these patients. The detection of structural and device-related mechanical abnormalities is critical for optimal functioning of assist device. In this review article, we describe the usefulness of TEE for optimal perioperative management of patients presenting for HeartWare LVAD insertion.

  5. Late outcomes of subcostal exchange of the HeartMate II left ventricular assist device: a word of caution.

    Science.gov (United States)

    Yu, Sarah N; Takayama, Hiroo; Han, Jiho; Garan, Arthur R; Kurlansky, Paul; Yuzefpolskaya, Melana; Colombo, Paolo C; Naka, Yoshifumi; Takeda, Koji

    2018-04-10

    Previous studies have shown the usefulness of the subcostal exchange of the HeartMate II left ventricular assist device for device malfunction. However, long-term data are still limited. Between March 2004 and July 2017, 41 of 568 (7.2%) patients who had received a HeartMate II implant at our institution had a device exchange via a subcostal incision. We summarized early and late outcomes. Forty-one patients had a total of 48 subcostal pump exchanges. Indications for device exchange included device thrombosis (n = 31, 76%), driveline infection (n = 2, 5%) and driveline injury (n = 8, 19%). All of the procedures were successful, and there were no in-hospital deaths. A Kaplan-Meier survival curve showed 30-day and 1-year survival rates after subcostal exchange of 100% and 94.6%, respectively. However, 10 (25%) patients had left ventricular assist device-related infections following subcostal exchange that included 7 pump pocket infections and 3 driveline infections. Freedom from left ventricular assist device-related infection at 1 year after subcostal exchange was 79.3%. Thirteen (32%) patients had device malfunction due to pump thrombosis that required a 2nd device exchange. Seven patients had recurrent thrombosis. Three (7%) patients had a stroke. Freedom from device thrombosis and from a stroke event at 1 year was 74.4%. Subcostal pump exchange can be safely performed. However, there is a substantial risk of infection and recurrent thrombosis. Careful follow-up for late complications is mandatory.

  6. Wave Intensity Analysis of Right Ventricular Function during Pulsed Operation of Rotary Left Ventricular Assist Devices.

    Science.gov (United States)

    Bouwmeester, J Christopher; Park, Jiheum; Valdovinos, John; Bonde, Pramod

    2018-05-29

    Changing the speed of left ventricular assist devices (LVADs) cyclically may be useful to restore aortic pulsatility; however, the effects of this pulsation on right ventricular (RV) function are unknown. This study investigates the effects of direct ventricular interaction by quantifying the amount of wave energy created by RV contraction when axial and centrifugal LVADs are used to assist the left ventricle. In 4 anesthetized pigs, pressure and flow were measured in the main pulmonary artery and wave intensity analysis was used to identify and quantify the energy of waves created by the RV. The axial pump depressed the intensity of waves created by RV contraction compared with the centrifugal pump. In both pump designs, there were only minor and variable differences between the continuous and pulsed operation on RV function. The axial pump causes the RV to contract with less energy compared with a centrifugal design. Diminishing the ability of the RV to produce less energy translates to less pressure and flow produced, which may lead to LVAD-induced RV failure. The effects of pulsed LVAD operation on the RV appear to be minimal during acute observation of healthy hearts. Further study is necessary to uncover the effects of other modes of speed modulation with healthy and unhealthy hearts to determine if pulsed operation will benefit patients by reducing LVAD complications.

  7. Calculation of the ALMA Risk of Right Ventricular Failure After Left Ventricular Assist Device Implantation.

    Science.gov (United States)

    Loforte, Antonio; Montalto, Andrea; Musumeci, Francesco; Amarelli, Cristiano; Mariani, Carlo; Polizzi, Vincenzo; Lilla Della Monica, Paola; Grigioni, Francesco; Di Bartolomeo, Roberto; Marinelli, Giuseppe

    2018-05-08

    Right ventricular failure after continuous-flow left ventricular assist device (LVAD) implantation is still an unsolved issue and remains a life-threatening event for patients. We undertook this study to determine predictors of the patients who are candidates for isolated LVAD therapy as opposed to biventricular support (BVAD). We reviewed demographic, echocardiographic, hemodynamic, and laboratory variables for 258 patients who underwent both isolated LVAD implantation and unplanned BVAD because of early right ventricular failure after LVAD insertion, between 2006 and 2017 (LVAD = 170 and BVAD = 88). The final study patients were randomly divided into derivation (79.8%, n = 206) and validation (20.1%, n = 52) cohorts. Fifty-seven preoperative risk factors were compared between patients who were successfully managed with an LVAD and those who required a BVAD. Nineteen variables demonstrated statistical significance on univariable analysis. Multivariable logistic regression analysis identified destination therapy (odds ratio [OR] 2.0 [1.7-3.9], p = 0.003), a pulmonary artery pulsatility index right ventricle/left ventricle end-diastolic diameter ratio >0.75 (OR 2.7 [1.5-5.5], p = 0.001), an right ventricle stroke work index 17 (OR 3.5 [1.9-6.9], p the major predictors of the need for BVAD. Using these data, we propose a simple risk calculator to determine the suitability of patients for isolated LVAD support in the era of continuous-flow mechanical circulatory support devices.

  8. Left Ventricular Assist Device Implantation with Concomitant Aortic Valve and Ascending Aortic Replacement.

    Science.gov (United States)

    Huenges, Katharina; Panholzer, Bernd; Cremer, Jochen; Haneya, Assad

    2018-01-01

    Left ventricular assist device (LVAD) is nowadays a routine therapy for patients with advanced heart failure. We present the case of a 74-year-old male patient who was admitted to our center with terminal heart failure in dilated cardiomyopathy and ascending aortic aneurysm with aortic valve regurgitation. The LVAD implantation with simultaneous aortic valve and supracoronary ascending aortic replacement was successfully performed.

  9. Beneficial aspects of real time flow measurements for the management of acute right ventricular heart failure following continuous flow ventricular assist device implantation

    Directory of Open Access Journals (Sweden)

    Spiliopoulos Sotirios

    2012-11-01

    Full Text Available Abstract Background Optimal management of acute right heart failure following the implantation of a left ventricular assist device requires a reliable estimation of left ventricular preload and contractility. This is possible by real-time pump blood flow measurements. Clinical case We performed implantation of a continuous flow left ventricular assist device in a 66 years old female patient with an end-stage heart failure on the grounds of a dilated cardiomyopathy. Real-time pump blood flow was directly measured by an ultrasonic flow probe placed around the outflow graft. Diagnosis The progressive decline of real time flow and the loss of pulsatility were associated with an increase of central venous pressure, inotropic therapy and progressive renal failure suggesting the presence of an acute right heart failure. Diagnosis was validated by echocardiography and thermodilution measurements. Treatment Temporary mechanical circulatory support of the right ventricle was successfully performed. Real time flow measurement proved to be a useful tool for the diagnosis and ultimately for the management of right heart failure including the weaning from extracorporeal membrane oxygenation.

  10. Impact of Tricuspid Valve Surgery at the Time of Left Ventricular Assist Device Insertion on Postoperative Outcomes

    OpenAIRE

    Dunlay, Shannon M.; Deo, Salil V.; Park, Soon J.

    2015-01-01

    Tricuspid regurgitation (TR) is common in patients with heart failure undergoing left ventricular assist device (LVAD) implantation. Whether the TR should be surgically managed at the time of LVAD surgery is controversial.

  11. Left ventricular assist device management in patients chronically supported for advanced heart failure.

    Science.gov (United States)

    Cowger, Jennifer; Romano, Matthew A; Stulak, John; Pagani, Francis D; Aaronson, Keith D

    2011-03-01

    This review summarizes management strategies to reduce morbidity and mortality in heart failure patients supported chronically with implantable left ventricular assist devices (LVADs). As the population of patients supported with long-term LVADs has grown, patient selection, operative technique, and patient management strategies have been refined, leading to improved outcomes. This review summarizes recent findings on LVAD candidate selection, and discusses outpatient strategies to optimize device performance and heart failure management. It also reviews important device complications that warrant close outpatient monitoring. Managing patients on chronic LVAD support requires regular patient follow-up, multidisciplinary care teams, and frequent laboratory and echocardiographic surveillance to ensure optimal outcomes.

  12. Psychological distress in patients with a left ventricular assist device and their partners : An exploratory study

    NARCIS (Netherlands)

    Brouwers, C.J.; Denollet, J.; Caliskan, K.; de Jonge, N.; Constantinescu, A.; Young, Q.; Kaan, A.; Pedersen, S.S.

    2015-01-01

    Background: Left ventricular assist device (LVAD) therapy is increasingly used in patients with advanced heart failure,and may have a significant psychological impact on both patients and their partners. Hence, we examined the distress levels of LVAD patients and their partners. Methods: Anxiety,

  13. Psychological distress in patients with a left ventricular assist device and their partners : an exploratory study

    NARCIS (Netherlands)

    Brouwers, Corline; Denollet, Johan; Caliskan, Kadir; de Jonge, N; Constantinescu, Alina; Young, Quincy; Kaan, Annemarie; Pedersen, Susanne S

    BACKGROUND: Left ventricular assist device (LVAD) therapy is increasingly used in patients with advanced heart failure, and may have a significant psychological impact on both patients and their partners. Hence, we examined the distress levels of LVAD patients and their partners. METHODS: Anxiety,

  14. Risk assessment and comparative effectiveness of left ventricular assist device and medical management in ambulatory heart failure patients: design and rationale of the ROADMAP clinical trial.

    Science.gov (United States)

    Rogers, Joseph G; Boyle, Andrew J; O'Connell, John B; Horstmanshof, Douglas A; Haas, Donald C; Slaughter, Mark S; Park, Soon J; Farrar, David J; Starling, Randall C

    2015-02-01

    Mechanical circulatory support is now a proven therapy for the treatment of patients with advanced heart failure and cardiogenic shock. The role for this therapy in patients with less severe heart failure is unknown. The objective of this study is to examine the impact of mechanically assisted circulation using the HeartMate II left ventricular assist device in patients who meet current US Food and Drug Administration-defined criteria for treatment but are not yet receiving intravenous inotropic therapy. This is a prospective, nonrandomized clinical trial of 200 patients treated with either optimal medical management or a mechanical circulatory support device. This trial will be the first prospective clinical evaluation comparing outcomes of patients with advanced ambulatory heart failure treated with either ongoing medical therapy or a left ventricular assist device. It is anticipated to provide novel insights regarding relative outcomes with each treatment and an understanding of patient and provider acceptance of the ventricular assist device therapy. This trial will also provide information regarding the risk of events in "stable" patients with advanced heart failure and guidance for the optimal timing of left ventricular assist device therapy. Copyright © 2014 Elsevier Inc. All rights reserved.

  15. The influence of device position on the flow within the Penn State 12 cc pediatric ventricular assist device.

    Science.gov (United States)

    Schönberger, Markus; Deutsch, Steven; Manning, Keefe B

    2012-01-01

    Ventricular assist devices are a commonly used heart failure therapy for adult patients as bridge-to-transplant or bridge-to-recovery tools. The application of adult ventricular assist devices in pediatric patients has led to increased thrombotic events. Therefore, we have been developing a pediatric ventricular assist device (PVAD), the Penn State 12 cc PVAD. It is designed for patients with a body weight of 5-15 kg and has a stroke volume of 12 cc. Clot formation is the major concern. It is correlated to the coagulability of blood, the blood contacting materials and the fluid dynamics within the system. The intent is for the PVAD to be a long term therapy. Therefore, the system may be oriented in different positions according to the patient's behavior. This study evaluates for the first time the impact of position on the flow patterns within the Penn State 12 cc PVAD, which may help to improve the PVAD design concerning chamber and ports geometries. The fluid dynamics are visualized by particle image velocimetry. The evaluation is based on inlet jet behavior and calculated wall shear rates. Vertical and horizontal model orientations are compared, both with a beat rate of 75, outlet pressures of 90/60 mm Hg and a flow rate of 1.3 l/min. The results show a significant change of the inlet jet behavior and the development of a rotational flow pattern. Vertically, the inlet jet is strong along the wall. It initiates a rotational flow pattern with a wandering axis of rotation. In contrast, the horizontal model orientation results show a weaker inlet jet along the wall with a nearly constant center of rotation location, which can be correlated to a higher risk of thrombotic events. In addition, high speed videography illustrates differences in the diaphragm motion during diastole. Diaphragm opening trajectories measurements determine no significant impact of the density of the blood analog fluids. Hence, the results correlate to human blood.

  16. Implantation of a HeartMate II left ventricular assist device via left thoracotomy.

    Science.gov (United States)

    Cho, Yang Hyun; Deo, Salil V; Schirger, John A; Pereira, Naveen L; Stulak, John M; Park, Soon J

    2012-11-01

    Left thoracotomy was used as an approach for the implantation of pulsatile ventricular assist devices. Avoiding the standard approach of median sternotomy is attractive in patients undergoing complicated redo cardiac surgery, especially with prior mediastinal radiation. We report a case of the use of left thoracotomy for the implantation of the HeartMate II axial-flow pump. Copyright © 2012 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  17. Minimally Invasive Cochlear Implantation Assisted by Bi-planar Device: An Exploratory Feasibility Study in vitro

    Directory of Open Access Journals (Sweden)

    Jia Ke

    2016-01-01

    Conclusions: This exploratory study demonstrated the safety of the newly developed image-guided minimally invasive cochlear implantation assisted by the bi-planar device and established the operational procedures. Further, more in vitro experiments are needed to improve the system operation and its safety.

  18. Detection of premature ventricular contractions on a ventricular electrocardiogram for patients with left ventricular assist devices.

    Science.gov (United States)

    Park, Sung Min; Lee, Jin Hong; Choi, Seong Wook

    2014-12-01

    The ventricular electrocardiogram (v-ECG) was developed for long-term monitoring of heartbeats in patients with a left ventricular assist device (LVAD) and does not normally have the functionality necessary to detect additional heart irregularities that can progress to critical arrhythmias. Although the v-ECG has the benefits of physiological optimization and counterpulsation control, when abnormal heartbeats occur, the v-ECG does not show the distinct abnormal waveform that enables easy detection of an abnormal heartbeat among normal heartbeats on the conventional ECG. In this study, the v-ECGs of normal and abnormal heartbeats are compared with each other with respect to peak-to-peak voltage, area, and maximal slopes, and a new method to detect abnormal heartbeats is suggested. In a series of animal experiments with three porcine models (Yorkshire pigs weighing 30-40 kg), a v-ECG and conventional ECG were taken simultaneously during LVAD perfusion. Clinical experts found 104 abnormal heartbeats from the saved conventional ECG data and confirmed that the other 3159 heartbeats were normal. Almost all of the abnormal heartbeats were premature ventricular contractions (PVCs), and there was short-term tachycardia for 3 s. A personal computer was used to automatically detect abnormal heartbeats with the v-ECG according to the new method, and its results were compared with the clinicians' results. The new method found abnormal heartbeats with 90% accuracy, and less than 15% of the total PVCs were missed. Copyright © 2014 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  19. Extracorporeal Life Support Bridge to Ventricular Assist Device: The Double Bridge Strategy.

    Science.gov (United States)

    Marasco, Silvana F; Lo, Casey; Murphy, Deirdre; Summerhayes, Robyn; Quayle, Margaret; Zimmet, Adam; Bailey, Michael

    2016-01-01

    In patients requiring left ventricular assist device (LVAD) support, it can be difficult to ascertain suitability for long-term mechanical support with LVAD and eventual transplantation. LVAD implantation in a shocked patient is associated with increased morbidity and mortality. Interest is growing in the utilization of extracorporeal life support (ECLS) as a bridge-to-bridge support for these critically unwell patients. Here, we reviewed our experience with ECLS double bridging. We hypothesized that ECLS double bridging would stabilize end-organ dysfunction and reduce ventricular assist device (VAD) implant perioperative mortality. We conducted a retrospective review of prospectively collected data for 58 consecutive patients implanted with a continuous-flow LVAD between January 2010 and December 2013 at The Alfred Hospital, Melbourne, Victoria, Australia. Twenty-three patients required ECLS support pre-LVAD while 35 patients underwent LVAD implantation without an ECLS bridge. Preoperative morbidity in the ECLS bridge group was reflected by increased postoperative intensive care duration, blood loss, blood product use, and postoperative renal failure, but without negative impact upon survival when compared with the no ECLS group. ECLS stabilization improved end-organ function pre-VAD implant with significant improvements in hepatic and renal dysfunction. This series demonstrates that the use of ECLS bridge to VAD stabilizes end-organ dysfunction and reduces VAD implant perioperative mortality from that traditionally reported in these "crash and burn" patients. Copyright © 2015 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  20. Use of Ventricular Assist Device in Univentricular Physiology: The Role of Lumped Parameter Models.

    Science.gov (United States)

    Di Molfetta, Arianna; Ferrari, Gianfranco; Filippelli, Sergio; Fresiello, Libera; Iacobelli, Roberta; Gagliardi, Maria G; Amodeo, Antonio

    2016-05-01

    Failing single-ventricle (SV) patients might benefit from ventricular assist devices (VADs) as a bridge to heart transplantation. Considering the complex physiopathology of SV patients and the lack of established experience, the aim of this work was to realize and test a lumped parameter model of the cardiovascular system, able to simulate SV hemodynamics and VAD implantation effects. Data of 30 SV patients (10 Norwood, 10 Glenn, and 10 Fontan) were retrospectively collected and used to simulate patients' baseline. Then, the effects of VAD implantation were simulated. Additionally, both the effects of ventricular assistance and cavopulmonary assistance were simulated in different pathologic conditions on Fontan patients, including systolic dysfunction, diastolic dysfunction, and pulmonary vascular resistance increment. The model can reproduce patients' baseline well. Simulation results suggest that the implantation of VAD: (i) increases the cardiac output (CO) in all the three palliation conditions (Norwood 77.2%, Glenn 38.6%, and Fontan 17.2%); (ii) decreases the SV external work (SVEW) (Norwood 55%, Glenn 35.6%, and Fontan 41%); (iii) increases the mean pulmonary arterial pressure (Pap) (Norwood 39.7%, Glenn 12.1%, and Fontan 3%). In Fontan circulation, with systolic dysfunction, the left VAD (LVAD) increases CO (35%), while the right VAD (RVAD) determines a decrement of inferior vena cava pressure (Pvci) (39%) with 34% increment of CO. With diastolic dysfunction, the LVAD increases CO (42%) and the RVAD decreases the Pvci. With pulmonary vascular resistance increment, the RVAD allows the highest CO (50%) increment with the highest decrement of Pvci (53%). The single ventricular external work (SVEW) increases (decreases) increasing the VAD speed in cavopulmonary (ventricular) assistance. Numeric models could be helpful in this challenging and innovative field to support patients and VAD selection to optimize the clinical outcome and personalize the therapy

  1. Bridge to transplantation with a left ventricular assist device.

    Science.gov (United States)

    Jung, Jae Jun; Sung, Kiick; Jeong, Dong Seop; Kim, Wook Sung; Lee, Young Tak; Park, Pyo Won

    2012-04-01

    A 61-year-old female patient was diagnosed with dilated cardiomyopathy with severe left ventricle dysfunction. Two days after admission, continuous renal replacement therapy was performed due to oliguria and lactic acidosis. On the fifth day, an intra-aortic balloon pump was inserted due to low cardiac output syndrome. Beginning 4 days after admission, she was supported for 15 days thereafter with an extracorporeal left ventricular assist device (LVAD) because of heart failure with multi-organ failure. A heart transplant was performed while the patient was stabilized with the LVAD. She developed several complications after the surgery, such as cytomegalovirus pneumonia, pulmonary tuberculosis, wound dehiscence, and H1N1 infection. On postoperative day 19, she was discharged from the hospital with close follow-up and treatment for infection. She received follow-up care for 10 months without any immune rejection reaction.

  2. An optimal controller for an electric ventricular-assist device: theory, implementation, and testing.

    Science.gov (United States)

    Klute, G K; Tasch, U; Geselowitz, D B

    1992-04-01

    This paper addresses the development and testing of an optimal position feedback controller for the Penn State electric ventricular-assist device (EVAD). The control law is designed to minimize the expected value of the EVAD's power consumption for a targeted patient population. The closed-loop control law is implemented on an Intel 8096 microprocessor and in vitro test runs show that this controller improves the EVAD's efficiency by 15-21%, when compared with the performance of the currently used feedforward control scheme.

  3. Flow Visualization of Three-Dimensionality Inside the 12 cc Penn State Pulsatile Pediatric Ventricular Assist Device

    OpenAIRE

    Roszelle, Breigh N.; Deutsch, Steven; Manning, Keefe B.

    2010-01-01

    In order to aid the ongoing concern of limited organ availability for pediatric heart transplants, Penn State has continued development of a pulsatile Pediatric Ventricular Assist Device (PVAD). Initial studies of the PVAD observed an increase in thrombus formation due to differences in flow field physics when compared to adult sized devices, which included a higher degree of three-dimensionality. This unique flow field brings into question the use of 2D planar particle image velocimetry (PIV...

  4. Exercise therapy for an older patient with left ventricular assist device.

    Science.gov (United States)

    Park, Won Hah; Seo, Yong Gon; Sung, Ji Dong

    2014-06-01

    A left ventricular assist device (LVAD) is a mechanical circulation support implanted for patients with end-stage heart failure. It may be used either as a bridge to cardiac transplantation or as a destination therapy. The health of a 75-year-old man with a medical history of systolic heart failure worsened. Therefore, he was recommended to have implanted a LVAD (Thoratec Corp.) as a destination therapy. After the surgery, he was enrolled in patient cardiac rehabilitation for the improvement of dyspnea and exercise capacity. In results, there is an improvement on his exercise capacity and quality of life. For the first time in Korea, we reported a benefit of exercise therapy after being implanted with a LVAD.

  5. Left ventricular assist device implantation in a patient who had previously undergone apical myectomy for hypertrophic cardiomyopathy.

    Science.gov (United States)

    Cho, Yang Hyun; Deo, Salil V; Topilsky, Yan; Grogan, Martha A; Park, Soon J

    2012-03-01

    Apical hypertrophy is a rare variant of hypertropic cardiomyopathy. These patients may present with end-stage congestive heart failure subsequent to long standing diastolic dysfunction. We report the technique for left ventricular assist device insertion in a patient with previous apical myectomy for hypertrophic cardiomyopathy. © 2012 Wiley Periodicals, Inc.

  6. Focused review on transthoracic echocardiographic assessment of patients with continuous axial left ventricular assist devices.

    Science.gov (United States)

    Topilsky, Yan; Maltais, Simon; Oh, Jae K; Atchison, Fawn W; Perrault, Louis P; Carrier, Michel; Park, Soon J

    2011-02-08

    Left ventricular assist devices (LVADs) are systems for mechanical support for patients with end-stage heart failure. Preoperative, postoperative and comprehensive followup with transthoracic echocardiography has a major role in LVAD patient management. In this paper, we will present briefly the hemodynamics of axial-flow LVAD, the rationale, and available data for a complete and organized echocardiographic assessment in these patients including preoperative assessment, postoperative and long-term evaluation.

  7. The effect of heart failure and left ventricular assist device treatment on right ventricular mechanics: a computational study.

    Science.gov (United States)

    Park, Jun I K; Heikhmakhtiar, Aulia Khamas; Kim, Chang Hyun; Kim, Yoo Seok; Choi, Seong Wook; Song, Kwang Soup; Lim, Ki Moo

    2018-05-22

    Although it is important to analyze the hemodynamic factors related to the right ventricle (RV) after left ventricular assist device (LVAD) implantation, previous studies have focused only on the alteration of the ventricular shape and lack quantitative analysis of the various hemodynamic parameters. Therefore, we quantitatively analyzed various hemodynamic parameters related to the RV under normal, heart failure (HF), and HF incorporated with continuous flow LVAD therapy by using a computational model. In this study, we combined a three-dimensional finite element electromechanical model of ventricles, which is based on human ventricular morphology captured by magnetic resonance imaging (MRI) with a lumped model of the circulatory system and continuous flow LVAD function in order to construct an integrated model of an LVAD implanted-cardiovascular system. To induce systolic dysfunction, the magnitude of the calcium transient function under HF condition was reduced to 70% of the normal value, and the time constant was reduced by 30% of the normal value. Under the HF condition, the left ventricular end systolic pressure decreased, the left ventricular end diastolic pressure increased, and the pressure in the right atrium (RA), RV, and pulmonary artery (PA) increased compared with the normal condition. The LVAD therapy decreased the end-systolic pressure of the LV by 41%, RA by 29%, RV by 53%, and PA by 71%, but increased the right ventricular ejection fraction by 52% and cardiac output by 40%, while the stroke work was reduced by 67% compared with the HF condition without LVAD. The end-systolic ventricular tension and strain decreased with the LVAD treatment. LVAD enhances CO and mechanical unloading of the LV as well as those of the RV and prevents pulmonary hypertension which can be induced by HF.

  8. Relation Between Pressure and Volume Unloading During Ramp Testing in Patients Supported with a Continuous-Flow Left Ventricular Assist Device

    DEFF Research Database (Denmark)

    Jung, Mette H; Hassager, Christian; Balling, Louise

    2015-01-01

    Pulmonary capillary wedge pressure (PCWP) is the key to describing left ventricular (LV) unloading, however, the relation between pressure and the echocardiography-derived surrogate of LV volume (left ventricular end-diastolic diameter (LVEDD)) as a function of pump speed (RPM) in continuous......-flow left ventricular assist device (CF-LVAD) patients is unknown. In this study the pressure-volume relationship as a function of RPM during ramp testing was investigated by simultaneously measuring PCWP by Swan-Ganz catheter and LVEDD by echocardiography. The ramp protocol started at usual pump setting...

  9. Enhancement of arterial pressure pulsatility by controlling continuous-flow left ventricular assist device flow rate in mock circulatory system

    NARCIS (Netherlands)

    Bozkurt, S.; van de Vosse, F.N.; Rutten, M.C.M.

    Continuous-flow left ventricular assist devices (CF-LVADs) generally operate at a constant speed, which reduces pulsatility in the arteries and may lead to complications such as functional changes in the vascular system, gastrointestinal bleeding, or both. The purpose of this study is to increase

  10. Computational fluid dynamics analysis of a maglev centrifugal left ventricular assist device.

    Science.gov (United States)

    Burgreen, Greg W; Loree, Howard M; Bourque, Kevin; Dague, Charles; Poirier, Victor L; Farrar, David; Hampton, Edward; Wu, Z Jon; Gempp, Thomas M; Schöb, Reto

    2004-10-01

    The fluid dynamics of the Thoratec HeartMate III (Thoratec Corp., Pleasanton, CA, U.S.A.) left ventricular assist device are analyzed over a range of physiological operating conditions. The HeartMate III is a centrifugal flow pump with a magnetically suspended rotor. The complete pump was analyzed using computational fluid dynamics (CFD) analysis and experimental particle imaging flow visualization (PIFV). A comparison of CFD predictions to experimental imaging shows good agreement. Both CFD and experimental PIFV confirmed well-behaved flow fields in the main components of the HeartMate III pump: inlet, volute, and outlet. The HeartMate III is shown to exhibit clean flow features and good surface washing across its entire operating range.

  11. An Implantable Intravascular Pressure Sensor for a Ventricular Assist Device

    Directory of Open Access Journals (Sweden)

    Luigi Brancato

    2016-08-01

    Full Text Available The aim of this study is to investigate the intravascular application of a micro-electro-mechanical system (MEMS pressure sensor to directly measure the hemodynamic characteristics of a ventricular assist device (VAD. A bio- and hemo-compatible packaging strategy is implemented, based on a ceramic thick film process. A commercial sub-millimeter piezoresistive sensor is attached to an alumina substrate, and a double coating of polydimethylsiloxane (PDMS and parylene-C is applied. The final size of the packaged device is 2.6 mm by 3.6 mm by 1.8 mm. A prototype electronic circuit for conditioning and read-out of the pressure signal is developed, satisfying the VAD-specific requirements of low power consumption (less than 14.5 mW in continuous mode and small form factor. The packaged sensor has been submitted to extensive in vitro tests. The device displayed a temperature-independent sensitivity (12 μ V/V/mmHg and good in vitro stability when exposed to the continuous flow of saline solution (less than 0.05 mmHg/day drift after 50 h. During in vivo validation, the transducer has been successfully used to record the arterial pressure waveform of a female sheep. A small, intravascular sensor to continuously register the blood pressure at the inflow and the outflow of a VAD is developed and successfully validated in vivo.

  12. Myocardial fibrosis and pro-fibrotic markers in end-stage heart failure patients during continuous-flow left ventricular assist device support

    NARCIS (Netherlands)

    Lok, Sjoukje I.; Nous, Fay M. A.; van Kuik, Joyce; van der Weide, Petra; Winkens, Bjorn; Kemperman, Hans; Huisman, Andre; Lahpor, Jaap R; de Weger, Roel A.; de Jonge, Nicolaas

    OBJECTIVES: During support with a left ventricular assist device (LVAD), partial reverse remodelling takes place in which fibrosis plays an important role. In this study, we analysed the histological changes and expression of fibrotic markers in patients with advanced heart failure (HF) during

  13. Successful Implantation of a Left Ventricular Assist Device After Treatment With the Paracor HeartNet.

    Science.gov (United States)

    Schweiger, Martin; Stepanenko, Alexander; Potapov, Evgenji; Drews, Thorsten; Hetzer, Roland; Krabatsch, Thomas

    2010-01-01

    The Paracor HeartNet, a ventricular constraint device for the treatment of heart failure (HF), is implanted through a left lateral thoracotomy. It envelopes the heart like a mesh "bag." This method of application raises the question of whether adhesions with the pericardium allow the safe implantation of a left ventricular assist device (LVAD) if HF worsens. A male patient who had undergone implantation of the Paracor HeartNet 42 months earlier presented with advanced HF for cardiac transplantation. The patient's condition deteriorated, and because no suitable organ for transplantation was available, implantation of an LVAD became necessary. Surgery was performed via a median sternotomy without complications. No severe adhesions were found. This is the first report on "how to do" LVAD implantation after Paracor HeartNet implantation with images and information about cutting the constraint. Because the Paracor HeartNet is "wrapped" around the heart, concerns persist that severe adhesions with the pericardium might occur. In this case, LVAD implantation after therapy with the Paracor HeartNet was without complications, and the expected massive adhesions were absent.

  14. Intraoperative Hemodynamic and Echocardiographic Measurements Associated With Severe Right Ventricular Failure After Left Ventricular Assist Device Implantation.

    Science.gov (United States)

    Gudejko, Michael D; Gebhardt, Brian R; Zahedi, Farhad; Jain, Ankit; Breeze, Janis L; Lawrence, Matthew R; Shernan, Stanton K; Kapur, Navin K; Kiernan, Michael S; Couper, Greg; Cobey, Frederick C

    2018-06-05

    Severe right ventricular failure (RVF) after left ventricular assist device (LVAD) implantation increases morbidity and mortality. We investigated the association between intraoperative right heart hemodynamic data, echocardiographic parameters, and severe versus nonsevere RVF. A review of LVAD patients between March 2013 and March 2016 was performed. Severe RVF was defined by the need for a right ventricular mechanical support device, inotropic, and/or inhaled pulmonary vasodilator requirements for >14 days. From a chart review, the right ventricular failure risk score was calculated and right heart hemodynamic data were collected. Pulmonary artery pulsatility index (PAPi) [(pulmonary artery systolic pressure - pulmonary artery diastolic pressure)/central venous pressure (CVP)] was calculated for 2 periods: (1) 30 minutes before cardiopulmonary bypass (CPB) and (2) after chest closure. Echocardiographic data were recorded pre-CPB and post-CPB by a blinded reviewer. Univariate logistic regression models were used to examine the performance of hemodynamic and echocardiographic metrics. A total of 110 LVAD patients were identified. Twenty-five did not meet criteria for RVF. Of the remaining 85 patients, 28 (33%) met criteria for severe RVF. Hemodynamic factors associated with severe RVF included: higher CVP values after chest closure (18 ± 9 vs 13 ± 5 mm Hg; P = .0008) in addition to lower PAPi pre-CPB (1.2 ± 0.6 vs 1.7 ± 1.0; P = .04) and after chest closure (0.9 ± 0.5 vs 1.5 ± 0.8; P = .0008). Post-CPB echocardiographic findings associated with severe RVF included: larger right atrial diameter major axis (5.4 ± 0.9 vs 4.9 ± 1.0 cm; P = .03), larger right ventricle end-systolic area (22.6 ± 8.4 vs 18.5 ± 7.9 cm; P = .03), lower fractional area of change (20.2 ± 10.8 vs 25.9 ± 12.6; P = .04), and lower tricuspid annular plane systolic excursion (0.9 ± 0.2 vs 1.1 ± 0.3 cm; P = .008). Right ventricular failure risk score was not a significant predictor of

  15. App-assisted external ventricular drain insertion.

    Science.gov (United States)

    Eftekhar, Behzad

    2016-09-01

    The freehand technique for insertion of an external ventricular drain (EVD) is based on fixed anatomical landmarks and does not take individual variations into consideration. A patient-tailored approach based on augmented-reality techniques using devices such as smartphones can address this shortcoming. The Sina neurosurgical assist (Sina) is an Android mobile device application (app) that was designed and developed to be used as a simple intraoperative neurosurgical planning aid. It overlaps the patient's images from previously performed CT or MRI studies on the image seen through the device camera. The device is held by an assistant who aligns the images and provides information about the relative position of the target and EVD to the surgeon who is performing EVD insertion. This app can be used to provide guidance and continuous monitoring during EVD placement. The author describes the technique of Sina-assisted EVD insertion into the frontal horn of the lateral ventricle and reports on its clinical application in 5 cases as well as the results of ex vivo studies of ease of use and precision. The technique has potential for further development and use with other augmented-reality devices.

  16. Carotid Doppler ultrasound findings in patients with left ventricular assist devices.

    Science.gov (United States)

    Cervini, Patrick; Park, Soon J; Shah, Dipesh K; Penev, Irina E; Lewis, Bradley D

    2010-12-01

    Left ventricular assist devices (LVADs) have been used to treat advanced heart failure refractory to medical management, as bridge therapy to myocardial recovery, as bridge therapy to cardiac transplantation, or as destination therapy for patients with unfavorable transplant candidacy. Neurologic complications are some of the most common and devastating complications in these patients. Preoperative carotid ultrasound is, therefore, a standard evaluation in patients at risk for cerebrovascular disease. Postoperative carotid artery Doppler sonography is performed in those patients with neurologic symptoms. It is likely, therefore, that sonographers, radiologists, and other physicians working in a center where LVADs are implanted will likely encounter a carotid artery Doppler study in this patient group. To our knowledge, the carotid Doppler findings in these patients have never been published. We review the Doppler ultrasound findings in 6 patients after LVAD insertion.

  17. "Pseudo" Faraday cage: a solution for telemetry link interaction between a left ventricular assist device and an implantable cardioverter defibrillator.

    Science.gov (United States)

    Jacob, Sony; Cherian, Prasad K; Ghumman, Waqas S; Das, Mithilesh K

    2010-09-01

    Patients implanted with left ventricular assist devices (LVAD) may have implantable cardioverter defibrillators (ICD) implanted for sudden cardiac death prevention. This opens the possibility of device-device communication interactions and thus interferences. We present a case of such interaction that led to ICD communication failure following the activation of an LVAD. In this paper, we describe a practical solution to circumvent the communication interference and review the communication links of ICDs and possible mechanisms of ICD-LVAD interactions.

  18. Prospective Randomized Evaluation of Implantable Cardioverter-Defibrillator Programming in Patients With a Left Ventricular Assist Device.

    Science.gov (United States)

    Richardson, Travis D; Hale, Leslie; Arteaga, Christopher; Xu, Meng; Keebler, Mary; Schlendorf, Kelly; Danter, Matthew; Shah, Ashish; Lindenfeld, JoAnn; Ellis, Christopher R

    2018-02-23

    Ventricular arrhythmias are common in patients with left ventricular assist devices (LVADs) but are often hemodynamically tolerated. Optimal implantable cardioverter defibrillator (ICD) tachy-programming strategies in patients with LVAD have not been determined. We sought to determine if an ultra-conservative ICD programming strategy in patients with LVAD affects ICD shocks. Adult patients with an existing ICD undergoing continuous flow LVAD implantation were randomized to standard ICD programming by their treating physician or an ultra-conservative ICD programming strategy utilizing maximal allowable intervals to detection in the ventricular fibrillation and ventricular tachycardia zones with use of ATP. Patients with cardiac resynchronization therapy (CRT) devices were also randomized to CRT ON or OFF. Patients were followed a minimum of 6 months. The primary outcome was time to first ICD shock. Among the 83 patients studied, we found no statistically significant difference in time to first ICD shock or total ICD shocks between groups. In the ultra-conservative group 16% of patients experienced at least one shock compared with 21% in the control group ( P =0.66). There was no difference in mortality, arrhythmic hospitalization, or hospitalization for heart failure. In the 41 patients with CRT ICDs fewer shocks were observed with CRT-ON but this was not statistically significant: 10% of patients with CRT-ON (n=21) versus 38% with CRT-OFF (n=20) received shocks ( P =0.08). An ultra-conservative programming strategy did not reduce ICD shocks. Programming restrictions on ventricular tachycardia and ventricular fibrillation zone therapy should be reconsidered for the LVAD population. The role of CRT in patients with LVAD warrants further investigation. URL: https://www.clinicaltrials.gov. Unique identifier: NCT01977703. © 2018 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  19. Cardiac transplantation after bridged therapy with continuous flow left ventricular assist devices.

    Science.gov (United States)

    Deo, Salil V; Sung, Kiick; Daly, Richard C; Shah, Ishan K; Altarabsheh, Salah E; Stulak, John M; Joyce, Lyle D; Boilson, Barry A; Kushwaha, Sudhir S; Park, Soon J

    2014-03-01

    Cardiac transplantation is an effective surgical therapy for end-stage heart failure. Patients (pts) may need to be bridged with a continuous flow left ventricular assist device (CF-LVAD) while on the transplant list as logistic factors like organ availability are unknown. Cardiac transplantation post-LVAD can be a surgically challenging procedure and outcome in these pts is perceived to be poorer based on experience with earlier generation pulsatile flow pumps. Data from a single institution comparing these pts with those undergoing direct transplantation in the present era of continuous flow device therapy are limited. Evaluate results of cardiac transplantation in pts bridged with a CF-LVAD (BTx) and compare outcomes with pts undergoing direct transplantation (Tx) in a single institution. From June 2007 till January 2012, 106 pts underwent cardiac transplantation. Among these, 37 (35%) pts (51±11 years; 85% male) were bridged with a CF-LVAD (BTx), while 70 (65%) comprised the Tx group (53±12 years; 72% males). The median duration of LVAD support was 227 (153,327) days. During the period of LVAD support, 10/37 (27%) pts were upgraded to status 1A and all were successfully transplanted. Median hospital stay in the BTx (14 days) was slightly longer than the Tx group (12 days) but not statistically significant (p=0.21). In-hospital mortality in the BTx (5%) and Tx (1%) were comparable (p=0.25). Estimated late survival in the BTx cohort was 94±7, 90±10 and 83±16% at the end of one, two and three years, respectively which was comparable to 97±4%, 93±6% and 89±9% for the Tx group (p=0.50). Cardiac transplantation after LVAD implant can be performed with excellent results. Patients can be supported on the left ventricular assist device even for periods close to a year with good outcome after cardiac transplantation. Copyright © 2013 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand

  20. Clinical Manifestations and Management of Left Ventricular Assist Device–Associated Infections

    OpenAIRE

    Nienaber, Juhsien Jodi C.; Kusne, Shimon; Riaz, Talha; Walker, Randall C.; Baddour, Larry M.; Wright, Alan J.; Park, Soon J.; Vikram, Holenarasipur R.; Keating, Michael R.; Arabia, Francisco A.; Lahr, Brian D.; Sohail, M. Rizwan

    2013-01-01

    We report the clinical manifestations and management of continuous-flow left ventricular assist device (LVAD) infections from a large multicenter cohort. On the basis of these observations, a management algorithm is derived to assist clinical decision making for LVAD infection.

  1. The pharmacotherapy implications of ventricular assist device in the patient with end-stage heart failure.

    Science.gov (United States)

    Von Ruden, Serena A S; Murray, Margaret A; Grice, Jennifer L; Proebstle, Amy K; Kopacek, Karen J

    2012-04-01

    Advances in mechanical circulatory support, such as the use of ventricular assist devices (VADs), have become a means for prolonging survival in end-stage heart failure (HF). VADs decrease the symptoms of HF and improve quality of life by replacing some of the work of a failing heart. They unload the ventricle to provide improved cardiac output and end-organ perfusion, resulting in improvement in cardiorenal syndromes and New York Heart Association functional class rating. VADs are currently used asa bridge to heart transplantation, a bridge to recovery of cardiac function, or as destination therapy. Complications of VAD include bleeding, infections, arrhythmias, multiple organ failure, right ventricular failure, and neurological dysfunction. Patients with VAD have unique pharmacotherapeutic requirements in terms of anticoagulation, appropriate antibiotic selection, and continuation of HF medications. Pharmacists in acute care and community settings are well prepared to care for the patient with VAD. These patients require thorough counseling and follow-up with regard to prevention and treatment of infections, appropriate levels of anticoagulation, and maintenance of fluid balance. A basic understanding of this unique therapy can assist pharmacists in attending to the needs of patients with VAD.

  2. Experience With a Long-term Pulsatile Ventricular Assist Device as a Bridge to Heart Transplant in Adults.

    Science.gov (United States)

    Gómez Bueno, Manuel; Segovia Cubero, Javier; Serrano Fiz, Santiago; Ugarte Basterrechea, Juan; Hernández Pérez, Francisco José; Goirigolzarri Artaza, Josebe; Castedo Mejuto, Evaristo; Burgos Lázaro, Raúl; García Montero, Carlos; Moñivas Palomero, Vanessa; Mingo Santos, Susana; González Román, Ana Isabel; Álvarez Avelló, José Manuel; Vidal Fernández, Mercedes; Forteza Gil, Alberto; Alonso-Pulpón, Luis

    2017-09-01

    Most long-term ventricular assist devices (VADs) that are currently implanted are intracorporeal continuous-flow devices. Their main limitations include their high cost and inability to provide biventricular support. The aim of this study was to describe the results of using paracorporeal pulsatile-flow VADs as a bridge to transplant (BTT) in adult patients. Retrospective analysis of the characteristics, complications, and outcomes of a single-center case series of consecutive patients treated with the EXCOR VAD as BTT between 2009 and 2015. During the study period, 25 VADs were implanted, 6 of them biventricular. Ventricular assist devices were indicated directly as a BTT in 12 patients and as a bridge to decision in 13 due to the presence of potentially reversible contraindications or chance of heart function recovery. Twenty patients (80%) were successfully bridged to heart transplant after a median of 112 days (range, 8-239). The main complications included infectious (52% of patients), neurological events (32%, half of them fatal), bleeding (28%), and VAD malfunction requiring component replacement (28%). Eighty percent of patients with the EXCOR VAD as BTT achieved the goal after an average of almost 4 months of support. The most frequent complications were infectious, and the most severe were neurological. In our enivonment, the use of these pulsatile-flow VAD as BTT is a feasible strategy that obtains similar outcomes to those of intracorporeal continuous-flow devices. Copyright © 2016 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  3. Impact of tricuspid valve surgery at the time of left ventricular assist device insertion on postoperative outcomes.

    Science.gov (United States)

    Dunlay, Shannon M; Deo, Salil V; Park, Soon J

    2015-01-01

    Tricuspid regurgitation (TR) is common in patients with heart failure undergoing left ventricular assist device (LVAD) implantation. Whether the TR should be surgically managed at the time of LVAD surgery is controversial. We searched SCOPUS, Web of Science, Ovid EMBASE, and Ovid MEDLINE (through May 10, 2014) for randomized controlled trials and observational studies comparing postoperative outcomes in patients treated with LVAD with concomitant tricuspid valve surgery (TVS) compared with LVAD alone. Six observational studies including 3,249 patients compared outcomes following LVAD + TVS versus LVAD. Four studies were single-center and most did not adjust for potential confounders. Addition of TVS prolonged cardiopulmonary bypass times by an average of 31 minutes (three studies, 95% CI 20-42). There was no difference in need for right ventricular assist device (six studies, HR 1.42, 95% CI 0.54-3.76), acute renal failure (four studies, HR 1.07, 95% CI 0.55-2.10), or early mortality (six studies, HR 1.28, 95% CI 0.78-2.08) in patients treated with LVAD + TVS versus LVAD alone. TVS prolongs cardiopulmonary bypass times, but available data demonstrate no significant association with early postoperative outcomes. However, differences in baseline risk of patients treated with TVS versus not limit our ability to draw conclusions.

  4. Hybrid approach of ventricular assist device and autologous bone marrow stem cells implantation in end-stage ischemic heart failure enhances myocardial reperfusion

    Directory of Open Access Journals (Sweden)

    Khayat Andre

    2011-01-01

    Full Text Available Abstract We challenge the hypothesis of enhanced myocardial reperfusion after implanting a left ventricular assist device together with bone marrow mononuclear stem cells in patients with end-stage ischemic cardiomyopathy. Irreversible myocardial loss observed in ischemic cardiomyopathy leads to progressive cardiac remodelling and dysfunction through a complex neurohormonal cascade. New generation assist devices promote myocardial recovery only in patients with dilated or peripartum cardiomyopathy. In the setting of diffuse myocardial ischemia not amenable to revascularization, native myocardial recovery has not been observed after implantation of an assist device as destination therapy. The hybrid approach of implanting autologous bone marrow stem cells during assist device implantation may eventually improve native cardiac function, which may be associated with a better prognosis eventually ameliorating the need for subsequent heart transplantation. The aforementioned hypothesis has to be tested with well-designed prospective multicentre studies.

  5. Developing an Anti-Xa-Based Anticoagulation Protocol for Patients with Percutaneous Ventricular Assist Devices.

    Science.gov (United States)

    Sieg, Adam; Mardis, B Andrew; Mardis, Caitlin R; Huber, Michelle R; New, James P; Meadows, Holly B; Cook, Jennifer L; Toole, J Matthew; Uber, Walter E

    2015-01-01

    Because of the complexities associated with anticoagulation in temporary percutaneous ventricular assist device (pVAD) recipients, a lack of standardization exists in their management. This retrospective analysis evaluates current anticoagulation practices at a single center with the aim of identifying an optimal anticoagulation strategy and protocol. Patients were divided into two cohorts based on pVAD implanted (CentriMag (Thoratec; Pleasanton, CA) / TandemHeart (CardiacAssist; Pittsburgh, PA) or Impella (Abiomed, Danvers, MA)), with each group individually analyzed for bleeding and thrombotic complications. Patients in the CentriMag/TandemHeart cohort were subdivided based on the anticoagulation monitoring strategy (activated partial thromboplastin time (aPTT) or antifactor Xa unfractionated heparin (anti-Xa) values). In the CentriMag/TandemHeart cohort, there were five patients with anticoagulation titrated based on anti-Xa values; one patient developed a device thrombosis and a major bleed, whereas another patient experienced major bleeding. Eight patients received an Impella pVAD. Seven total major bleeds in three patients and no thrombotic events were detected. Based on distinct differences between the devices, anti-Xa values, and outcomes, two protocols were created to guide anticoagulation adjustments. However, anticoagulation in patients who require pVAD support is complex with constantly evolving anticoagulation goals. The ideal level of anticoagulation should be individually determined using several coagulation laboratory parameters in concert with hemodynamic changes in the patient's clinical status, the device, and the device cannulation.

  6. First pediatric transatlantic air ambulance transportation on a Berlin Heart EXCOR left ventricular assist device as a bridge to transplantation.

    Science.gov (United States)

    Tissot, Cecile; Buchholz, Holger; Mitchell, Max B; da Cruz, Eduardo; Miyamoto, Shelley D; Pietra, Bill A; Charpentier, Arnaud; Ghez, Olivier

    2010-03-01

    Mechanical circulatory devices are indicated in patients with refractory cardiac failure as a bridge to recovery or to transplantation. Whenever required, transportation while on mechanical support is a challenge and still limited by technical restrictions or distance. We report the first pediatric case of transatlantic air transportation on a Berlin Heart EXCOR ventricular assist device (Berlin Heart, Berlin, Germany) of a 13-yr-old American female who presented in cardiogenic shock with severe systolic dysfunction while vacationing in France. Rapid hemodynamic deterioration occurred despite maximal medical treatment, and she was supported initially with extracorporeal membrane oxygenation converted to a Berlin Heart EXCOR left ventricular assist device. Long-distance air transportation of the patient was accomplished 3 wks after implantation from Marseille, France, to Denver, Colorado. No adverse hemodynamic effects were encountered during the 13.5-hr flight (8770 km). The patient did not recover sufficient cardiac function and underwent successful orthotopic heart transplantation 3 months after the initial event. Our experience suggests that long-distance air transportation of pediatric patients using the Berlin Heart EXCOR mobile unit as a bridge to recovery or transplantation is feasible and appears safe.

  7. Pump speed modulations and sub-maximal exercise tolerance in left ventricular assist device recipients

    DEFF Research Database (Denmark)

    Jung, Mette Holme; Houston, Brian; Russell, Stuart D

    2017-01-01

    of the 2 sub-maximal tests was determined by randomization. Both patient and physician were blinded to the sequence. Exercise duration, oxygen consumption (VO2) and rate of perceived exertion (RPE), using the Borg scale (score 6 to 20), were recorded. RESULTS: Nineteen patients (all with a HeartMate II...... ventricular assist device) completed 57 exercise tests. Baseline pump speed was 9,326 ± 378 rpm. At AT, workload was 63 ± 26 W (25 to 115 W) and VO2 was 79 ± 14% of maximum. Exercise duration improved by 106 ± 217 seconds (~13%) in Speedinc compared with Speedbase (837 ± 358 vs 942 ± 359 seconds; p = 0...

  8. Evolution of general surgical problems in patients with left ventricular assist devices.

    Science.gov (United States)

    McKellar, Stephen H; Morris, David S; Mauermann, William J; Park, Soon J; Zietlow, Scott P

    2012-11-01

    Left ventricular assist devices (LVADs) are increasingly used to treat patients with end-stage heart failure. These patients may develop acute noncardiac surgical problems around the time of LVAD implantation or, as survival continues to improve, chronic surgical problems as ambulatory patients remote from the LVAD implant. Previous reports of noncardiac surgical problems in LVAD patients included patients with older, first-generation devices and do not address newer, second-generation devices. We describe the frequency and management of noncardiac surgical problems encountered during LVAD support with these newer-generation devices to assist noncardiac surgeons involved in the care of patients with LVADs. We retrospectively reviewed the medical records of consecutive patients receiving LVADs at our institution. We collected data for any consultation by noncardiac surgeons within the scope of general surgery during LVAD support and subsequent treatment. Ninety-nine patients received implantable LVADs between 2003 and 2009 (first-generation, n = 19; second-generation, n = 80). Excluding intestinal hemorrhage, general surgical opinions were rendered for 34 patients with 49 problems, mostly in the acute recovery phase after LVAD implantation. Of those, 27 patients underwent 28 operations. Respiratory failure and intra-abdominal pathologies were the most common problems addressed, and LVAD rarely precluded operation. Patients with second-generation LVADs were more likely to survive hospitalization (P = .04) and develop chronic, rather than emergent, surgical problems. Patients with LVADs frequently require consultation from noncardiac surgeons within the scope of general surgeons and often require operation. Patients with second-generation LVADs are more likely to become outpatients and develop more elective surgical problems. Noncardiac surgeons will be increasingly involved in caring for patients with LVADs and should anticipate the problems unique to this patient

  9. Development of ventricular assist devices in China: present status, opportunities and challenges.

    Science.gov (United States)

    Gu, Kaiyun; Chang, Yu; Gao, Bin; Wan, Feng; Loisance, Daniel; Zeng, Yi

    2014-08-01

    The growing number of heart failure patients and the scarcity of organ donors account for the huge need for the development of mechanical circulatory systems, including ventricular assist devices (VADs) and artificial hearts, in China. Several research programmes on blood pumps have been under way for the last three decades. However, unlike in other countries, the development of VADs has been extremely slow, and no system is currently approved and available for clinical application. There are many reasons for this situation. This article provides an overview of the present development of experimental and clinical research on VADs in China. In addition, the challenges for the clinical development of mechanical circulatory support in China are discussed. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  10. The Ventricular Assist Device in the Life of the Child: A Phenomenological Pediatric Study.

    Science.gov (United States)

    van Manen, Michael A

    2017-05-01

    What is it like for a child to live with an artificial heart? The use of some medical therapies in children requires developmental considerations, is associated with psychosocial consequences, and calls for ethical sensitivities. A critical case is the ventricular assist device (VAD), a mechanical pump used to support the functioning of a failing heart. As a pediatric therapy, the device can be used as a temporary solution for poor heart function, a bridge to transplantation or recovery, or as a destination therapy. While the mechanical-technical operation of the VAD is well understood, the clinical-technical aspects of young people living with this device are largely unexplored. Drawing on interviews of school-aged children, the aim of this phenomenological study is to explore how a VAD may structure or condition a child's meaningful experience of their world outside the hospital. The driveline of an implanted VAD is the peripheral attachment, extruding through the skin to connect the controller-power supply. The materiality of the device may be interruptive, restrictive, and disturbing to the psycho-physical being and sense of self-identity of the child as a child. And while a child equipped with a VAD is not necessarily conspicuous among other children, the child may experience the device as an exposing presence, while living with the worry of a caregiver who takes on the role not simply of parent but of watchful health professional. A phenomenological understanding of the VAD should assist parents and caregiving health professionals knowing how to deal with specific issues arising in the life of the VAD child.

  11. Anchoring in Destination-Therapy Left Ventricular Assist Device Decision Making: A Mechanical Turk Survey.

    Science.gov (United States)

    Paine, Arcadia M; Allen, Larry A; Thompson, Jocelyn S; McIlvennan, Colleen K; Jenkins, Amy; Hammes, Andrew; Kroehl, Miranda; Matlock, Daniel D

    2016-11-01

    People with end-stage heart failure may have to decide about destination-therapy left ventricular assist device (DT-LVAD). Individuals facing difficult decisions often rely on heuristics, such as anchoring, which predictably bias decision outcomes. We aimed to investigate whether showing a larger historical Heartmate XVE creates an anchoring effect, making the smaller Heartmate II (HMII) appear more favorable. With the use of Amazon Mechanical Turk, participants watched videos asking them to imagine themselves dying of end-stage heart failure, then were presented the option of LVAD as potentially life-prolonging therapy. Participants were randomized to a control group who were only shown the HMII device, and the intervention group who saw the XVE device before the HMII. Participants then completed surveys. A total of 487 participants completed the survey (control = 252; intervention = 235); 79% were affect likelihood of accepting the LVAD, it did affect device perception. This article highlights an important point with clinical implications: factors such as anchoring have the potential to inappropriately influence perceptions and decisions and should be carefully considered in research and practice. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Multidrug Resistant Pseudomonas Mycotic Pseudoaneurysm following Cardiac Transplant Bridged by Ventricular Assistant Device

    Directory of Open Access Journals (Sweden)

    C. Aye

    2017-01-01

    Full Text Available Mycotic pseudoaneurysm of aorta following cardiac surgery is rare but is highly fatal if it is unrecognized and untreated. Here, we report a case of a 45-year-old male patient who presented with rapidly progressive multiple pseudoaneurysms of the ascending aorta infected with multidrug resistant (MDR Pseudomonas aeruginosa at 5 weeks after cardiac transplantation, on a background of prior bridging therapy with left ventricular assistant device (LVAD. The patient was successfully treated with the newer cephalosporin, Ceftolozane/Tazobactam, in combination with surgery. This is the first reported case of mycotic pseudoaneurysm infected with MDR Pseudomonas. This case also highlights the importance of high vigilance and timely multimodality treatment in the diagnosis and management of mycotic pseudoaneurysm following cardiac transplant, especially in patients who had LVAD.

  13. Anesthesia for left ventricular assist device insertion: a case series and review.

    Science.gov (United States)

    Broussard, David; Donaldson, Emilie; Falterman, Jason; Bates, Michael

    2011-01-01

    From October 2008 to June 2010, a total of 42 patients had the HeartMate II left ventricular assist device inserted surgically at Ochsner Medical Center in New Orleans, LA. A retrospective electronic record review was conducted on this series of patients to analyze elements of perioperative anesthetic care, including general anesthetic care, echocardiographic considerations, and blood product usage. Etomidate was used to induce anesthesia for 34 of 42 patients (81%) in this series, with an average dose of 16.5 mg (±6 mg). The average intraoperative fentanyl dose was 1,318 µg (±631 µg). On average, patients were extubated 91 hours (±72 hours) after arrival to the intensive care unit and left on day 9 (±5 days). The average left ventricular ejection fraction of the patients in this series was 13% (±5%). Sixteen patients were evaluated as having severe right-heart dysfunction preoperatively. Two of 42 patients required surgical closure of echocardiographically identified patent foramen ovale. Twelve of 42 patients underwent surgical correction of tricuspid regurgitation. On average, 3 units (±2.6 units) of fresh frozen plasma were transfused intraoperatively and 10 units postoperatively. Intraoperative red blood cell usage averaged 1.1 units (maximum, 7 units), with an average 9.3 units administered in the first 48 hours postoperatively.

  14. The Ventricular Assist Device in the Life of the Child: A Phenomenological Pediatric Study

    Science.gov (United States)

    van Manen, Michael A.

    2017-01-01

    What is it like for a child to live with an artificial heart? The use of some medical therapies in children requires developmental considerations, is associated with psychosocial consequences, and calls for ethical sensitivities. A critical case is the ventricular assist device (VAD), a mechanical pump used to support the functioning of a failing heart. As a pediatric therapy, the device can be used as a temporary solution for poor heart function, a bridge to transplantation or recovery, or as a destination therapy. While the mechanical-technical operation of the VAD is well understood, the clinical-technical aspects of young people living with this device are largely unexplored. Drawing on interviews of school-aged children, the aim of this phenomenological study is to explore how a VAD may structure or condition a child’s meaningful experience of their world outside the hospital. The driveline of an implanted VAD is the peripheral attachment, extruding through the skin to connect the controller-power supply. The materiality of the device may be interruptive, restrictive, and disturbing to the psycho-physical being and sense of self-identity of the child as a child. And while a child equipped with a VAD is not necessarily conspicuous among other children, the child may experience the device as an exposing presence, while living with the worry of a caregiver who takes on the role not simply of parent but of watchful health professional. A phenomenological understanding of the VAD should assist parents and caregiving health professionals knowing how to deal with specific issues arising in the life of the VAD child. PMID:28682718

  15. Is exercise training safe and beneficial in patients receiving left ventricular assist device therapy?

    Science.gov (United States)

    Alsara, Osama; Perez-Terzic, Carmen; Squires, Ray W; Dandamudi, Sanjay; Miranda, William R; Park, Soon J; Thomas, Randal J

    2014-01-01

    Because a limited number of patients receive heart transplantation, alternative therapies, such as left ventricular assist device (LVAD) therapy, have emerged. Published studies have shown that LVAD implantation, by itself, improves exercise tolerance to the point where it is comparable to those with mild heart failure. The improvement in exercise capacity is maximally achieved 12 weeks after LVAD therapy and can continue even after explantation of the device. This effect varies, depending on the type of LVAD and exercise training. The available data in the literature on safety and benefits of exercise training in patients after LVAD implantation are limited, but the data that are available suggest that training trends to be safe and have an impact on exercise capacity in LVAD patients. Although no studies were identified on the role of cardiac rehabilitation programs in the management of LVAD patients, it appears that cardiac rehabilitation programs offer an ideal setting for the provision of supervised exercise training in this patient group.

  16. Right ventricular longitudinal strain and right ventricular stroke work index in patients with severe heart failure: left ventricular assist device suitability for transplant candidates.

    Science.gov (United States)

    Cameli, M; Bernazzali, S; Lisi, M; Tsioulpas, C; Croccia, M G; Lisi, G; Maccherini, M; Mondillo, S

    2012-09-01

    Right ventricular (RV) systolic function has a critical role in determining the clinical outcome and the success of using left ventricular assist devices in patients with refractory heart failure. RV deformation analysis by speckle tracking echocardiography (STE) has recently allowed the analysis of RV longitudinal function. Using cardiac catheterization as the reference standard, this study aimed to explore the correlation between RV longitudinal function by STE and RV stroke work index (RVSWI) among patients referred for cardiac transplantation. Right heart catheterization and transthoracic echo-Doppler were simultaneously performed in 47 patients referred for cardiac transplant assessment due to refractory heart failure (ejection fraction 25.1 ± 4.5%). Thermodilution RV stroke volume and invasive pulmonary pressures were used to obtain RVSWI. RV longitudinal strain (RVLS) by STE was assessed averaging RV free-wall segments (free-wall RVLS). We also calculated. Tricuspid S' and tricuspid annular plane systolic excursion (TAPSE). No significant correlation was observed for TAPSE on tricuspid S' with RV stroke volume (r = 0.14 and r = 0.06, respectively). A close negative correlation between free-wall RVLS and RVSWI was found (r = -0.82; P rights reserved.

  17. Experimental Assessment of the Hydraulics of a Miniature Axial-Flow Left Ventricular Assist Device

    Science.gov (United States)

    Smith, P. Alex; Cohn, William; Metcalfe, Ralph

    2017-11-01

    A minimally invasive partial-support left ventricular assist device (LVAD) has been proposed with a flow path from the left atrium to the arterial system to reduce left ventricular stroke work. In LVAD design, peak and average efficiency must be balanced over the operating range to reduce blood trauma. Axial flow pumps have many geometric parameters. Until recently, testing all these parameters was impractical, but modern 3D printing technology enables multi-parameter studies. Following theoretical design, experimental hydraulic evaluation in steady state conditions examines pressure, flow, pressure-flow gradient, efficiency, torque, and axial force as output parameters. Preliminary results suggest that impeller blades and stator vanes with higher inlet angles than recommended by mean line theory (MLT) produce flatter gradients and broader efficiency curves, increasing compatibility with heart physiology. These blades also produce less axial force, which reduces bearing load. However, they require slightly higher torque, which is more demanding of the motor. MLT is a low order, empirical model developed on large pumps. It does not account for the significant viscous losses in small pumps like LVADs. This emphasizes the importance of experimental testing for hydraulic design. Roderick D MacDonald Research Fund.

  18. Left ventricular assist device: exercise capacity evolution and rehabilitation added value.

    Science.gov (United States)

    Lamotte, Michel X; Chimenti, Sara; Deboeck, Gael; Gillet, Alexis; Kacelenenbogen, Raymond; Strapart, Jonathan; Vandeneynde, Frédéric; Van Nooten, Guido; Antoine, Martine

    2018-06-01

    With more than 15,000 implanted patients worldwide and a survival rate of 80% at 1-year and 59% at 5-years, left ventricular assist device (LVAD) implantation has become an interesting strategy in the management of heart failure patients who are resistant to other kinds of treatment. There are limited data in the literature on the change over time of exercise capacity in LVAD patients, as well as limited knowledge about the beneficial effects that rehabilitation might have on these patients. Therefore, the aim of our study was to evaluate the evolution of exercise capacity on a cohort of patients implanted with the same device (HeartWare © ) and to analyse the potential impact of rehabilitation. Sixty-two patients implanted with a LVAD between June 2011 and June 2015 were screened. Exercise capacity was evaluated by cardiopulmonary exercise testing at 6 weeks, 6 and 12 months after implantation. We have observed significant differences in the exercise capacity and evolution between the trained and non-trained patients. Some of the trained patients nearly normalised their exercise capacity at the end of the rehabilitation programme. Exercise capacity of patient implanted with a HeartWare © LVAD increased in the early period after implantation. Rehabilitation allowed implanted patients to have a significantly better evolution compared to non-rehabilitated patients.

  19. Heat Generation in Axial and Centrifugal Flow Left Ventricular Assist Devices.

    Science.gov (United States)

    Yost, Gardner; Joseph, Christine Rachel; Royston, Thomas; Tatooles, Antone; Bhat, Geetha

    Despite increasing use of left ventricular assist devices (LVADs) as a surgical treatment for advanced heart failure in an era of improved outcomes with LVAD support, the mechanical interactions between these pumps and the cardiovascular system are not completely understood. We utilized an in vitro mock circulatory loop to analyze the heat production incurred by operation of an axial flow and centrifugal flow LVAD. A HeartMate II and a HeartWare HVAD were connected to an abbreviated flow loop and were implanted in a viscoelastic gel. Temperature was measured at the surface of each LVAD. Device speed and fluid viscosity were altered and, in the HeartMate II, as artificial thrombi were attached to the inflow stator, impeller, and outflow stator. The surface temperatures of both LVADs increased in all trials and reached a plateau within 80 minutes of flow initiation. Rate of heat generation and maximum system temperature were greater when speed was increased, when viscosity was increased, and when artificial thrombi were attached to the HeartMate II impeller. Normal operation of these two widely utilized LVADs results in appreciable heat generation in vitro. Increased pump loading resulted in more rapid heat generation, which was particularly severe when a large thrombus was attached to the impeller of the HeartMate II. While heat accumulation in vivo is likely minimized by greater dissipation in the blood and soft tissues, focal temperature gains with the pump housing of these two devices during long-term operation may have negative hematological consequences.

  20. Fluoroscopy-Guided Resolution of Ingested Thrombus Leading to Functional Disturbance of a Continuous-Flow Left Ventricular Assist Device

    Directory of Open Access Journals (Sweden)

    Jens Garbade

    2012-01-01

    Full Text Available The third generation of left ventricular assist devices (LVADs has been shown to improve outcome and quality of life in patients suffering from acute and chronic heart failure. However, VAD-associated complications are still a challenge in the clinical practice. Here we report the resolution of a mobile thrombus formation in the proximity of the inflow cannula of a third generation of LVADs (HVAD Pump, HeartWare, Inc. in a patient with chronic heart failure 4 months after implantation.

  1. Assessment of Safety and Effectiveness of the Extracorporeal Continuous-Flow Ventricular Assist Device (BR16010) Use as a Bridge-to-Decision Therapy for Severe Heart Failure or Refractory Cardiogenic Shock: Study Protocol for Single-Arm Non-randomized, Uncontrolled, and Investigator-Initiated Clinical Trial.

    Science.gov (United States)

    Fukushima, Norihide; Tatsumi, Eisuke; Seguchi, Osamu; Takewa, Yoshiaki; Hamasaki, Toshimitsu; Onda, Kaori; Yamamoto, Haruko; Hayashi, Teruyuki; Fujita, Tomoyuki; Kobayashi, Junjiro

    2018-06-08

    The management of heart failure patients presenting in a moribund state remains challenging, despite significant advances in the field of ventricular assist systems. Bridge to decision involves using temporary devices to stabilize the hemodynamic state of such patients while further assessment is performed and a decision can be made regarding patient management. The purpose of this study (NCVC-BTD_01, National Cerebral and Cardiovascular Center-Bridge to Dicision_01) is to assess the safety and effectiveness of the newly developed extracorporeal continuous-flow ventricular assist system employing a disposable centrifugal pump with a hydrodynamically levitated bearing (BR16010) use as a bridge-to-decision therapy for patients with severe heart failure or refractory cardiogenic shock. NCVC-BTD_01 is a single-center, single-arm, open-label, exploratory, medical device, investigator-initiated clinical study. It is conducted at the National Cerebral and Cardiovascular Center in Japan. A total of nine patients will be enrolled in the study. The study was planned using Simon's minimax two-stage phase design. The primary endpoint is a composite of survival free of device-related serious adverse events and complications during device support. For left ventricular assistance, withdrawal of a trial device due to cardiac function recovery or exchange to other ventricular assist devices (VADs) for the purpose of bridge to transplantation (BTT) during 30 days after implantation will be considered study successes. For right ventricular assistance, withdrawal of tal device due to right ventricular function recovery within 30 days after implantation will be considered a study success. Secondary objectives include changes in brain natriuretic peptide levels (7 days after implantation of a trial device and the day of withdrawal of a trial device), period of mechanical ventricular support, changes in left ventricular ejection fraction (7 days after implantation of a trial device

  2. Carotid Artery Stenting in a Patient With a Continuous-Flow Left Ventricular Assist Device.

    Science.gov (United States)

    Piazza, Michele; Squizzato, Francesco; Grego, Franco; Bottio, Tommaso; Gerosa, Gino; Antonello, Michele

    2016-08-01

    To demonstrate the safety and feasibility of carotid artery stenting (CAS) in a patient with a continuous-flow left ventricular assist device (LVAD). A 54-year-old woman with a LVAD was referred for a 90% stenosis of the right internal carotid artery (ICA). The patient was offered CAS, and oral anticoagulant was not discontinued in the periprocedural period. Because of absent arterial pulses, percutaneous transfemoral access was obtained under ultrasound guidance. Particular attention was paid to cannulation of the innominate artery; a 7-F guiding catheter was advanced from the descending aorta into the innominate artery under road-mapping, avoiding maneuvers in the ascending aorta where the outflow Dacron graft of the LVAD was anastomosed. To avoid cerebral flow modifications, the Angioguard RX was used as the cerebral protection device rather than other devices such as the flow reversal or flow-clamping systems. At this point, CAS was performed in a standard fashion using the 7×30-mm Precise ProRX stent. The computed tomography angiogram at 6 months showed patency of the stented right ICA. With adequate planning, CAS appears feasible in patients with a LVAD. © The Author(s) 2016.

  3. Pulsatile operation of a continuous-flow right ventricular assist device (RVAD) to improve vascular pulsatility.

    Science.gov (United States)

    Ng, Boon C; Kleinheyer, Matthias; Smith, Peter A; Timms, Daniel; Cohn, William E; Lim, Einly

    2018-01-01

    Despite the widespread acceptance of rotary blood pump (RBP) in clinical use over the past decades, the diminished flow pulsatility generated by a fixed speed RBP has been regarded as a potential factor that may lead to adverse events such as vasculature stiffening and hemorrhagic strokes. In this study, we investigate the feasibility of generating physiological pulse pressure in the pulmonary circulation by modulating the speed of a right ventricular assist device (RVAD) in a mock circulation loop. A rectangular pulse profile with predetermined pulse width has been implemented as the pump speed pattern with two different phase shifts (0% and 50%) with respect to the ventricular contraction. In addition, the performance of the speed modulation strategy has been assessed under different cardiovascular states, including variation in ventricular contractility and pulmonary arterial compliance. Our results indicated that the proposed pulse profile with optimised parameters (Apulse = 10000 rpm and ωmin = 3000 rpm) was able to generate pulmonary arterial pulse pressure within the physiological range (9-15 mmHg) while avoiding undesirable pump backflow under both co- and counter-pulsation modes. As compared to co-pulsation, stroke work was reduced by over 44% under counter-pulsation, suggesting that mechanical workload of the right ventricle can be efficiently mitigated through counter-pulsing the pump speed. Furthermore, our results showed that improved ventricular contractility could potentially lead to higher risk of ventricular suction and pump backflow, while stiffening of the pulmonary artery resulted in increased pulse pressure. In conclusion, the proposed speed modulation strategy produces pulsatile hemodynamics, which is more physiologic than continuous blood flow. The findings also provide valuable insight into the interaction between RVAD speed modulation and the pulmonary circulation under various cardiovascular states.

  4. Noninvasive arterial blood pressure waveforms in patients with continuous-flow left ventricular assist devices.

    Science.gov (United States)

    Martina, Jerson R; Westerhof, Berend E; de Jonge, Nicolaas; van Goudoever, Jeroen; Westers, Paul; Chamuleau, Steven; van Dijk, Diederik; Rodermans, Ben F M; de Mol, Bas A J M; Lahpor, Jaap R

    2014-01-01

    Arterial blood pressure and echocardiography may provide useful physiological information regarding cardiac support in patients with continuous-flow left ventricular assist devices (cf-LVADs). We investigated the accuracy and characteristics of noninvasive blood pressure during cf-LVAD support. Noninvasive arterial pressure waveforms were recorded with Nexfin (BMEYE, Amsterdam, The Netherlands). First, these measurements were validated simultaneously with invasive arterial pressures in 29 intensive care unit patients. Next, the association between blood pressure responses and measures derived by echocardiography, including left ventricular end-diastolic dimensions (LVEDDs), left ventricular end-systolic dimensions (LVESDs), and left ventricular shortening fraction (LVSF) were determined during pump speed change procedures in 30 outpatients. Noninvasive arterial blood pressure waveforms by the Nexfin monitor slightly underestimated invasive measures during cf-LVAD support. Differences between noninvasive and invasive measures (mean ± SD) of systolic, diastolic, mean, and pulse pressures were -7.6 ± 5.8, -7.0 ± 5.2, -6.9 ± 5.1, and -0.6 ± 4.5 mm Hg, respectively (all blood pressure responses did not correlate with LVEDD, LVESD, or LVSF, while LVSF correlated weakly with both pulse pressure (r = 0.24; p = 0.005) and (dP(art)/dt)max (r = 0.25; p = 0.004). The dicrotic notch in the pressure waveform was a better predictor of aortic valve opening (area under the curve [AUC] = 0.87) than pulse pressure (AUC = 0.64) and (dP(art)/dt)max (AUC = 0.61). Patients with partial support rather than full support at 9,000 rpm had a significant change in systolic pressure, pulse pressure, and (dP(art)/dt)max during ramp studies, while echocardiographic measures did not change. Blood pressure measurements by Nexfin were reliable and may thereby act as a compliment to the assessment of the cf-LVAD patient.

  5. Identification of non-HLA antibodies in ventricular assist device recipients

    Directory of Open Access Journals (Sweden)

    Sandy von Salisch

    2013-11-01

    Full Text Available Aims Recipients of ventricular assist devices (VADR have a higher incidence to develop antibodies (Abs against human leukocyte antigens (HLA. Non-HLA antibodies like major histocompatibility complex class I-related chain A (MICA and autoantibodies against angiotensin type 1 receptor (AT1R and endothelin receptor A (ETAR are also implicated in the pathogenesis of acute rejection and allograft vasculopathy. We monitored non-HLA- and HLA-Abs in VADR up to one year after implantation. Materials and methods Sera of 56 VADR (54.1±12.8 years old, 50 men were analyzed for Abs against HLA-, MICA-, AT1R- and ETAR several times over one year after implantation using ELISA and Luminex xMAP technology. Blood transfusions, gender and age were reviewed. Results Sera of 56 VADR (54.1±12.8 years old, 50 men were analyzed for Abs against HLA-, MICA-, AT1R- and ETAR several times over one year after implantation using ELISA and Luminex xMAP technology. Blood transfusions, gender and age were reviewed. Conclusion Beside HLA- and MICA-Abs, VADR showed high titres of Abs against AT1R or ETAR, which underlines the necessity for monitoring non-HLA antibodies in VADR prior heart transplantation.

  6. Exercise physiology, testing, and training in patients supported by a left ventricular assist device.

    Science.gov (United States)

    Loyaga-Rendon, Renzo Y; Plaisance, Eric P; Arena, Ross; Shah, Keyur

    2015-08-01

    The left ventricular assist device (LVAD) is an accepted treatment alternative for the management of end-stage heart failure. As we move toward implantation of LVADs in less severe cases of HF, scrutiny of functional capacity and quality of life becomes more important. Patients demonstrate improvements in exercise capacity after LVAD implantation, but the effect is less than predicted. Exercise training produces multiple beneficial effects in heart failure patients, which would be expected to improve quality of life. In this review, we describe factors that are thought to participate in the persistent exercise impairment in LVAD-supported patients, summarize current knowledge about the effect of exercise training in LVAD-supported patients, and suggest areas for future research. Copyright © 2015 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

  7. The NHLBI REVIVE-IT study: Understanding its discontinuation in the context of current left ventricular assist device therapy.

    Science.gov (United States)

    Pagani, Francis D; Aaronson, Keith D; Kormos, Robert; Mann, Douglas L; Spino, Cathie; Jeffries, Neal; Taddei-Peters, Wendy C; Mancini, Donna M; McNamara, Dennis M; Grady, Kathleen L; Gorcsan, John; Petrucci, Ralph; Anderson, Allen S; Glick, Henry A; Acker, Michael A; Eduardo Rame, J; Goldstein, Daniel J; Pamboukian, Salpy V; Miller, Marissa A; Timothy Baldwin, J

    2016-11-01

    The National Institutes of Health National Heart, Lung, and Blood Institute convened a working group in March 2008 to discuss how therapies for heart failure (HF) might be best advanced using clinical trials involving left ventricular assist devices (LVAD). This group opined that the field was ready for a trial to assess the use of long-term ventricular assist device therapy in patients who are less ill than patients currently eligible for destination therapy, which resulted in the Randomized Evaluation of VAD InterVEntion before Inotropic Therapy (REVIVE-IT) pilot study. The specific objective of REVIVE-IT was to compare LVAD therapy with optimal medical management in patients with less advanced HF than current LVAD indications to determine if wider application of permanent LVAD use to less ill patients would be associated with improved survival, quality of life, or functional capacity. REVIVE-IT represented an extraordinary effort to provide data from a randomized clinical trial to inform clinicians, scientists, industry, and regulatory agencies about the efficacy and safety of LVAD therapy in a population with less advanced HF. Despite significant support from the medical community, industry, and governmental agencies, REVIVE-IT failed to accomplish its goal. The reasons for its failure are instructive, and the lessons learned from the REVIVE-IT experience are likely to be relevant to any future study of LVAD therapy in a population with less advanced HF. Copyright © 2016 International Society for Heart and Lung Transplantation. All rights reserved.

  8. Left ventricular assist device exchange: the Toronto General Hospital experience.

    Science.gov (United States)

    Tsubota, Hideki; Ribeiro, Roberto V P; Billia, Filio; Cusimano, Robert J; Yau, Terrence M; Badiwala, Mitesh V; Stansfield, William E; Rao, Vivek

    2017-08-01

    As support times for left ventricular assist devices (LVADs) become longer, several complications requiring device exchange may occur. To our knowledge, this is the first Canadian report regarding implantable LVAD exchange. We retrospectively reviewed the cases of consecutive, unique patients implanted with an LVAD between June 2006 and October 2015 at Toronto General Hospital. In total, 122 patients were impanted with an LVAD during the study period. Eight patients required LVAD exchange, and 1 patient had 2 replacements (9 of 122, 7.3%). There were 7 HeartMate II (HMII), 1 HVAD and 1 DuraHeart pumps exchanged. Two of these exchanges occurred early at the time of initial implant, whereas 7 occurred late (range 8-623 d). Six exchanges were made owing to pump thrombosis. Of the 3 exchanges made for other causes, 1 HMII exchange was owing to a driveline fracture, 1 DuraHeart patient had early inflow obstruction requiring exchange to HMII at the initial implant, and the third had a suspected inflow obstruction with no evidence of thrombosis at the time of the procedure. The mean support time before exchange was 225 days, and time from exchange to transplant, death or ongoing support was 245 days. Three patients were successfully bridged to transplant, and at the time of data collection 2 were supported awaiting transplant. Three patients died after a mean duration of 394.3 days (range 78-673 d) of support postreplacement. Four cases were successfully performed using a subcostal approach. Pump thrombosis is the most common cause for LVAD exchange, which can be performed with acceptable morbidity and mortality. The subcostal approach may be the preferred procedure for an HMII exchange when indicated.

  9. Outflow monitoring of a pneumatic ventricular assist device using external pressure sensors.

    Science.gov (United States)

    Kang, Seong Min; Her, Keun; Choi, Seong Wook

    2016-08-25

    In this study, a new algorithm was developed for estimating the pump outflow of a pneumatic ventricular assist device (p-VAD). The pump outflow estimation algorithm was derived from the ideal gas equation and determined the change in blood-sac volume of a p-VAD using two external pressure sensors. Based on in vitro experiments, the algorithm was revised to consider the effects of structural compliance caused by volume changes in an implanted unit, an air driveline, and the pressure difference between the sensors and the implanted unit. In animal experiments, p-VADs were connected to the left ventricles and the descending aorta of three calves (70-100 kg). Their outflows were estimated using the new algorithm and compared to the results obtained using an ultrasonic blood flow meter (UBF) (TS-410, Transonic Systems Inc., Ithaca, NY, USA). The estimated and measured values had a Pearson's correlation coefficient of 0.864. The pressure sensors were installed at the external controller and connected to the air driveline on the same side as the external actuator, which made the sensors easy to manage.

  10. Clinical manifestations and management of left ventricular assist device-associated infections.

    Science.gov (United States)

    Nienaber, Juhsien Jodi C; Kusne, Shimon; Riaz, Talha; Walker, Randall C; Baddour, Larry M; Wright, Alan J; Park, Soon J; Vikram, Holenarasipur R; Keating, Michael R; Arabia, Francisco A; Lahr, Brian D; Sohail, M Rizwan

    2013-11-01

    Infection is a serious complication of left ventricular assist device (LVAD) therapy. Published data regarding LVAD-associated infections (LVADIs) are limited by single-center experiences and use of nonstandardized definitions. We retrospectively reviewed 247 patients who underwent continuous-flow LVAD implantation from January 2005 to December 2011 at Mayo Clinic campuses in Minnesota, Arizona, and Florida. LVADIs were defined using the International Society for Heart and Lung Transplantation criteria. We identified 101 episodes of LVADI in 78 patients (32%) from this cohort. Mean age (± standard deviation [SD]) was 57±15 years. The majority (94%) underwent Heartmate II implantation, with 62% LVADs placed as destination therapy. The most common type of LVADIs were driveline infections (47%), followed by bloodstream infections (24% VAD related, and 22% non-VAD related). The most common causative pathogens included gram-positive cocci (45%), predominantly staphylococci, and nosocomial gram-negative bacilli (27%). Almost half (42%) of the patients were managed by chronic suppressive antimicrobial therapy. While 14% of the patients had intraoperative debridement, only 3 underwent complete LVAD removal. The average duration (±SD) of LVAD support was 1.5±1.0 years. At year 2 of follow-up, the cumulative incidence of all-cause mortality was estimated to be 43%. Clinical manifestations of LVADI vary on the basis of the type of infection and the causative pathogen. Mortality remained high despite combined medical and surgical intervention and chronic suppressive antimicrobial therapy. Based on clinical experiences, a management algorithm for LVADI is proposed to assist in the decision-making process.

  11. A modified Glenn shunt reduces right ventricular stroke work during left ventricular assist device therapy.

    Science.gov (United States)

    Schiller, Petter; Vikholm, Per; Hellgren, Laila

    2016-03-01

    Right ventricular (RV) failure is a major cause of morbidity and mortality after left ventricular assist device (LVAD) placement and remains hard to predict. We hypothesized that partial surgical exclusion of the RV with a modified Glenn shunt during LVAD treatment would reduce RV stroke work. An LVAD was implanted in eight pigs and a modified Glenn shunt was constructed. A conductance pressure-volume catheter was placed in the right ventricle through the apex. Haemodynamic data and pressure-volume loops were obtained at the following time periods: (i) baseline, (ii) open shunt, (iii) LVAD with closed shunt and (iii) LVAD and open shunt. During LVAD therapy, the right atrial (RA) pressure increased from 9 mmHg (9-9) to 15 mmHg (12-15), P = 0.01. RV stroke volume increased from 30 ml (29-40) to 51 ml (42-53), P work increased to 708 mmHg ml (654-1193) from 535 mmHg ml (424-717), P = 0.04, compared with baseline. During LVAD therapy in combination with a Glenn shunt, the RA pressure decreased from 15 mmHg (12-15) to 10 mmHg (7-11) when compared with LVAD therapy only, P = 0.01. A decrease in RV stroke work from 708 mmHg ml (654-1193) to 465 mmHg ml (366-711), P = 0.04, was seen when the LVAD was combined with a shunt, not significantly different from the baseline value (535 mmHg ml). The developed pressure in the right ventricle decreased from 29 mmHg (26-32) to 21 mmHg (20-24), P work during the use of the shunt with LVAD treatment. A modified Glenn shunt reduced RV volumes, RV stroke work and RA pressure during LVAD therapy in an experimental model of heart failure in pigs. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  12. Ramp Study Hemodynamics, Functional Capacity, and Outcome in Heart Failure Patients with Continuous-Flow Left Ventricular Assist Devices

    DEFF Research Database (Denmark)

    Jung, Mette H; Gustafsson, Finn; Houston, Brian

    2016-01-01

    Ramp studies-measuring changes in cardiac parameters as a function of serial pump speed changes (revolutions per minute [rpm])-are increasingly used to evaluate function and malfunction of continuous-flow left ventricular assist devices (CF-LVADs). We hypothesized that ramp studies can predict...... patients (HeartMate II, Thoratec Corporation, Pleasanton, CA). Functional status was evaluated in 70% (31/44); average 6 minute walk test (6MWT) was 312 ± 220 min, New York Heart Association (NYHA) I-II/III-IV (70/30%) and activity scores very low-low/moderate-very high (55/45%). Decrease in pulmonary...

  13. SdrF, a Staphylococcus epidermidis surface protein, contributes to the initiation of ventricular assist device driveline-related infections.

    Directory of Open Access Journals (Sweden)

    Carlos Arrecubieta

    2009-05-01

    Full Text Available Staphylococcus epidermidis remains the predominant pathogen in prosthetic-device infections. Ventricular assist devices, a recently developed form of therapy for end-stage congestive heart failure, have had considerable success. However, infections, most often caused by Staphylococcus epidermidis, have limited their long-term use. The transcutaneous driveline entry site acts as a potential portal of entry for bacteria, allowing development of either localized or systemic infections. A novel in vitro binding assay using explanted drivelines obtained from patients undergoing transplantation and a heterologous lactococcal system of surface protein expression were used to identify S. epidermidis surface components involved in the pathogenesis of driveline infections. Of the four components tested, SdrF, SdrG, PIA, and GehD, SdrF was identified as the primary ligand. SdrF adherence was mediated via its B domain attaching to host collagen deposited on the surface of the driveline. Antibodies directed against SdrF reduced adherence of S. epidermidis to the drivelines. SdrF was also found to adhere with high affinity to Dacron, the hydrophobic polymeric outer surface of drivelines. Solid phase binding assays showed that SdrF was also able to adhere to other hydrophobic artificial materials such as polystyrene. A murine model of infection was developed and used to test the role of SdrF during in vivo driveline infection. SdrF alone was able to mediate bacterial adherence to implanted drivelines. Anti-SdrF antibodies reduced S. epidermidis colonization of implanted drivelines. SdrF appears to play a key role in the initiation of ventricular assist device driveline infections caused by S. epidermidis. This pluripotential adherence capacity provides a potential pathway to infection with SdrF-positive commensal staphylococci first adhering to the external Dacron-coated driveline at the transcutaneous entry site, then spreading along the collagen

  14. Stroke Risk and Mortality in Patients With Ventricular Assist Devices.

    Science.gov (United States)

    Parikh, Neal S; Cool, Joséphine; Karas, Maria G; Boehme, Amelia K; Kamel, Hooman

    2016-11-01

    Ventricular assist devices (VADs) have advanced the management of end-stage heart failure. However, these devices are associated with hemorrhagic and thrombotic complications, including stroke. We assessed the incidence, risk factors, and outcomes of ischemic and hemorrhagic stroke after VAD placement. Using administrative claims data from acute care hospitals in California, Florida, and New York from 2005 to 2013, we identified patients who underwent VAD placement, defined by the International Classification of Diseases, Ninth Revision, Clinical Modification code 37.66. Ischemic and hemorrhagic strokes were identified by previously validated coding algorithms. We used survival statistics to determine the incidence rates and Cox proportional hazard analyses to examine the associations. Among 1813 patients, we identified 201 ischemic strokes and 116 hemorrhagic strokes during 3.4 (±2.0) years of follow-up after implantation of a VAD. The incidence of stroke was 8.7% per year (95% confidence interval [CI], 7.7-9.7). The annual incidence of ischemic stroke (5.5%; 95% CI, 4.8-6.4) was nearly double that of hemorrhagic stroke (3.1%; 95% CI, 2.6-3.8). Women faced a higher hazard of stroke than men (hazard ratio, 1.6; 95% CI, 1.2-2.1), particularly hemorrhagic stroke (hazard ratio, 2.2; 95% CI, 1.4-3.4). Stroke was strongly associated with subsequent in-hospital mortality (hazard ratio, 6.1; 95% CI, 4.6-7.9). The incidence of stroke after VAD implantation was 8.7% per year, and incident stroke was strongly associated with subsequent in-hospital mortality. Notably, ischemic stroke occurred at nearly twice the rate of hemorrhagic stroke. Women seemed to face a higher risk for hemorrhagic stroke than men. © 2016 American Heart Association, Inc.

  15. General and acute care surgical procedures in patients with left ventricular assist devices.

    Science.gov (United States)

    Arnaoutakis, George J; Bittle, Gregory J; Allen, Jeremiah G; Weiss, Eric S; Alejo, Jennifer; Baumgartner, William A; Shah, Ashish S; Wolfgang, Christopher L; Efron, David T; Conte, John V

    2014-04-01

    Left ventricular assist devices (LVADs) have become common as a bridge to heart transplant as well as destination therapy. Acute care surgical (ACS) problems in this population are prevalent but remain ill-defined. Therefore, we reviewed our experience with ACS interventions in LVAD patients. A total of 173 patients who received HeartMate(®) XVE or HeartMate(®) II (HMII) LVADs between December 2001 and March 2010 were studied. Patient demographics, presentation of ACS problem, operative intervention, co-morbidities, transplantation, complications, and survival were analyzed. A total of 47 (27 %) patients underwent 67 ACS procedures at a median of 38 days after device implant (interquartile range 15-110), with a peri-operative mortality rate of 5 % (N = 3). Demographics, device type, and acuity were comparable between the ACS and non-ACS groups. A total of 21 ACS procedures were performed emergently, eight were urgent, and 38 were elective. Of 29 urgent and emergent procedures, 28 were for abdominal pathology. In eight patients, the cause of the ACS problem was related to LVADs or anticoagulation. Cumulative survival estimates revealed no survival differences if patients underwent ACS procedures (p = 0.17). Among HMII patients, transplantation rates were unaffected by an ACS intervention (p = 0.2). ACS problems occur frequently in LVAD patients and are not associated with adverse outcomes in HMII patients. The acute care surgeon is an integral member of a comprehensive approach to effective LVAD management.

  16. Reduced Anxiety and Depression in Patients With Advanced Heart Failure After Left Ventricular Assist Device Implantation.

    Science.gov (United States)

    Yost, Gardner; Bhat, Geetha; Mahoney, Edward; Tatooles, Antone

    Despite the high prevalence of depression and anxiety in patients with advanced heart failure, the effects of left ventricular assist device (LVAD) implantation on these critically important aspects of mental health are not well understood. We sought to assess changes in depression and anxiety following LVAD implantation. The Beck Depression Inventory-II (BDI-II) and Beck Anxiety Inventory (BAI) were administered to 54 patients by a clinical psychologist at a mean of 12 days before LVAD implantation and 251 days after implantation. Patient demographics and clinical data were collected concurrently to psychologic testing. Changes in BDI-II, BAI, and clinical markers of heart failure were assessed using paired t-tests. A p Psychosomatic Medicine. Published by Elsevier Inc. All rights reserved.

  17. Simulation of Ventricular, Cavo-Pulmonary, and Biventricular Ventricular Assist Devices in Failing Fontan.

    Science.gov (United States)

    Di Molfetta, Arianna; Amodeo, Antonio; Fresiello, Libera; Trivella, Maria Giovanna; Iacobelli, Roberta; Pilati, Mara; Ferrari, Gianfranco

    2015-07-01

    Considering the lack of donors, ventricular assist devices (VADs) could be an alternative to heart transplantation for failing Fontan patients, in spite of the lack of experience and the complex anatomy and physiopathology of these patients. Considering the high number of variables that play an important role such as type of Fontan failure, type of VAD connection, and setting (right VAD [RVAD], left VAD [LVAD], or biventricular VAD [BIVAD]), a numerical model could be useful to support clinical decisions. The aim of this article is to develop and test a lumped parameter model of the cardiovascular system simulating and comparing the VAD effects on failing Fontan. Hemodynamic and echocardiographic data of 10 Fontan patients were used to simulate the baseline patients' condition using a dedicated lumped parameter model. Starting from the simulated baseline and for each patient, a systolic dysfunction, a diastolic dysfunction, and an increment of the pulmonary vascular resistance were simulated. Then, for each patient and for each pathology, the RVAD, LVAD, and BIVAD implantations were simulated. The model can reproduce patients' baseline well. In the case of systolic dysfunction, the LVAD unloads the single ventricle and increases the cardiac output (CO) (35%) and the arterial systemic pressure (Pas) (25%). With RVAD, a decrement of inferior vena cava pressure (Pvci) (39%) was observed with 34% increment of CO, but an increment of the single ventricle external work (SVEW). With the BIVAD, an increment of Pas (29%) and CO (37%) was observed. In the case of diastolic dysfunction, the LVAD increases CO (42%) and the RVAD decreases the Pvci, while both increase the SVEW. In the case of pulmonary vascular resistance increment, the highest CO (50%) and Pas (28%) increment is obtained with an RVAD with the highest decrement of Pvci (53%) and an increment of the SVEW but with the lowest VAD power consumption. The use of numerical models could be helpful in this innovative

  18. Successful Implantation of a Left Ventricular Assist Device in a Patient with Heparin-Induced Thrombocytopenia and Thrombosis

    Science.gov (United States)

    Garland, Cassandra; Somogyi, David

    2014-01-01

    Abstract: We report the case of a 27-year-old woman with signs of heparin-induced thrombocytopenia and thrombosis (HITT) and left heart failure presenting for urgent implantation of a left ventricular assist device (LVAD). HITT can occur in 4.2–6.1% of patients with LVADs. If the patient remains hemodynamically stable, implantation can be delayed for several months until the heparin/PF-4 antibodies decline allowing the use of heparin on cardiopulmonary bypass, However, in most cases related to cardiogenic shock, surgery cannot be delayed. We present the case of a patient who underwent implantation of a HeartMate II LVAD and discuss management strategy using bivalirudin during cardiopulmonary bypass. PMID:25208434

  19. The role of cerebral hyperperfusion in postoperative neurologic dysfunction after left ventricular assist device implantation for end-stage heart failure.

    Science.gov (United States)

    Lietz, Katherine; Brown, Kevin; Ali, Syed S; Colvin-Adams, Monica; Boyle, Andrew J; Anderson, David; Weinberg, Alan D; Miller, Leslie W; Park, Soon; John, Ranjit; Lazar, Ronald M

    2009-04-01

    Cerebral hyperperfusion is a life-threatening syndrome that can occur in patients with chronically hypoperfused cerebral vasculature whose normal cerebral circulation was re-established after carotid endarterectomy or angioplasty. We sought to determine whether the abrupt restoration of perfusion to the brain after left ventricular assist device (LVAD) implantation produced similar syndromes. We studied the role of increased systemic flow after LVAD implantation on neurologic dysfunction in 69 consecutive HeartMate XVE LVAD (Thoratec, Pleasanton, Calif) recipients from October 2001 through June 2006. Neurologic dysfunction was defined as postoperative permanent or transient central change in neurologic status, including confusion, focal neurologic deficits, visual changes, seizures, or coma for more than 24 hours within 30 days after LVAD implantation. We found that 19 (27.5%) patients had neurologic dysfunction, including encephalopathy (n = 11), coma (n = 3), and other complications (n = 5). The multivariate analysis showed that an increase in cardiac index from the preoperative baseline value (relative risk, 1.33 per 25% cardiac index increase; P = .01) and a previous coronary bypass operation (relative risk, 4.53; P = .02) were the only independent predictors of neurologic dysfunction. Reduction of left ventricular assist device flow in 16 of the 19 symptomatic patients led to improvement of symptoms in 14 (87%) patients. Our findings showed that normal flow might overwhelm cerebral autoregulation in patients with severe heart failure, suggesting that cerebral hyperperfusion is possible in recipients of mechanical circulatory support with neurologic dysfunction.

  20. Continuous flow left ventricular assist devices: shared care goals of monitoring and treating patients.

    Science.gov (United States)

    Estep, Jerry D; Trachtenberg, Barry H; Loza, Laurie P; Bruckner, Brian A

    2015-01-01

    Continuous-flow left ventricular assist devices (CF-LVADs) have been clinically adopted as a long-term standard of care therapy option for patients with end-stage heart failure. For many patients, shared care between the care providers at the implanting center and care providers in the community in which the patient resides is a clinical necessity. The aims of this review are to (1) provide a rationale for the outpatient follow-up exam and surveillance testing used at our center to monitor patients supported by the HeartMate II(®) CF-LVAD (Thoratec Corporation, Pleasanton, CA) and (2) provide the protocol/algorithms we use for blood pressure, driveline exit site, LVAD alarm history, surveillance blood work, and echocardiography monitoring in this patient population. In addition, we define our partnership outpatient follow-up protocol and the "shared care" specific responsibilities we use with referring health care providers to best manage many of our patients.

  1. Bridge to transplantation using paracorporeal biventricular assist devices or the syncardia temporary total artificial heart: is there a difference?

    Science.gov (United States)

    Nguyen, A; Pozzi, M; Mastroianni, C; Léger, P; Loisance, D; Pavie, A; Leprince, P; Kirsch, M

    2015-06-01

    Biventricular support can be achieved using paracorporeal ventricular assist devices (p-BiVAD) or the Syncardia temporary total artificial heart (t-TAH). The purpose of the present study was to compare survival and morbidity between these devices. Data from 2 French neighboring hospitals were reviewed. Between 1996 and 2009, 148 patients (67 p-BiVADs and 81 t-TAH) underwent primary, planned biventricular support. There were 128 (86%) males aged 44±13 years. Preoperatively, p-BiVAD recipients had significantly lower systolic and diastolic blood pressures, more severe hepatic cytolysis and higher white blood cell counts than t-TAH recipients. In contrast, t-TAH patients had significantly higher rates of pre-implant ECLS and hemofiltration. Mean support duration was 79±100 days for the p-BiVAD group and 71±92 for t-TAH group (P=0.6). Forty two (63%) p-BiVAD recipients were bridged to transplantation (39, 58%) or recovery (3, 5%), whereas 51 (63%) patients underwent transplantation in the t-TAH group. Death on support was similar between groups (p-BiVAD, 26 (39%); t-TAH, 30 (37%); P=0.87). Survival while on device was not significantly different between patient groups and multivariate analysis showed that only preimplant diastolic blood pressure and alanine amino-transferase levels were significant predictors of death. Post-transplant survival in the p-BiVAD group was 76±7%, 70±8%, and 58±9% at 1, 3, and 5 years after transplantation, respectively, and was similar to that of the t-TAH group (77±6%, 72±6%, and 70±7%, P=0.60). Survival while on support and up to 5 years after heart transplantation was not significantly different in patients supported by p-BiVADs or t-TAH. Multivariate analysis revealed that survival while on transplantation was not affected by the type of device implanted.

  2. Non-Invasive Mapping of Intraventricular Flow Patterns in Patients Treated with Left Ventricular Assist Devices

    Science.gov (United States)

    Miramontes, Marissa; Rossini, Lorenzo; Braun, Oscar; Brambatti, Michela; Almeida, Shone; Mizeracki, Adam; Martinez-Legazpi, Pablo; Benito, Yolanda; Bermejo, Javier; Kahn, Andrew; Adler, Eric; Del Álamo, Juan C.

    2017-11-01

    In heart failure patients, left ventricular (LV) assist devices (LVADs) decrease mortality and improve quality of life. We hypothesize echo color Doppler velocimetry (echo-CDV), an echocardiographic flow mapping modality, can non-invasively characterize the effect of LVAD support, optimize the device, thereby decreasing the stoke rate present in these patients. We used echo-CDV to image LV flow at baseline LVAD speed and during a ramp test in LVAD patients (Heartmate II, N =10). We tracked diastolic vortices and mapped blood stasis and cumulative shear. Compared to dilated cardiomyopathy (DCM) patients without LVADs, the flow had a less prominent diastolic vortex ring, and transited directly from mitral valve to cannula. Residence time and shear were significantly lower compared to healthy controls and DCMs. Aortic regurgitation and a large LV vortex presence or a direct mitral jet towards the cannula affected blood stasis region location and size. Flow patterns, residence time and shear depended on LV geometry, valve function and LVAD speed in a patient specific manner. This new methodology could be used with standard echo, hemodynamics and clinical information to find the flow optimizing LAVD setting minimizing stasis for each patient.

  3. Outcomes of ventricular assist device implantation in children and young adults: the Melbourne experience.

    Science.gov (United States)

    Shi, William Y; Marasco, Silvana F; Saxena, Pankaj; d'Udekem, Yves; Yong, Matthew S; Mitnovetski, Sergei; Brizard, Christian P; McGiffin, David C; Weintraub, Robert G; Konstantinov, Igor E

    2016-12-01

    We evaluated our experience with ventricular assist device (VAD) implantation in children and young adults. A total of 64 patients underwent VAD implantation in two centres. The mean age was 15 ± 7.2 years. Thirty-five (55%) patients were under 18 years of age. Devices implanted included the Thoratec Paracorporeal in 30 (47%) patients, Berlin Heart EXCOR in 11 (17%) and VentrAssist in 14 (22%). The diagnosis was cardiomyopathy in 53, congenital heart disease in 11, and graft failure in four patients. There were 10 (16%) in-hospital deaths. Mortality was higher in patients <18 years of age (26% compared with 3.4% for those ≥18 years, P = 0.02). The use of extracorporeal membrane oxygenation prior to VAD implantation was associated with higher mortality (P = 0.006). Seventeen (27%) patients experienced stroke. Nine patients (14%) required change of VAD because of thrombosis. Transplantation was performed in 44 patients after a mean of 131 ± 141 days on VAD, 11 patients died without transplantation and three patients currently await transplantation. The VAD was explanted in six patients because of recovery. Overall survival from VAD implantation was 69% and 61% at 5 and 10 years, respectively. The 5-year post-transplant survival for those bridged with VAD support was 91% and was comparable with a cohort of patients who did not receive a pre-transplant VAD. Children requiring pre-transplant VAD support have a higher mortality and morbidity compared with young adults. Survival after heart transplantation those supported with VADs was similar to patients of similar age who did not require pre-transplant support. © 2015 Royal Australasian College of Surgeons.

  4. Neurohormonal activation and exercise tolerance in patients supported with a continuous-flow left ventricular assist device

    DEFF Research Database (Denmark)

    Jung, Mette Holme; Goetze, Jens Peter; Boesgaard, Soeren

    2016-01-01

    BACKGROUND: Neurohormones play a key role in regulating hemodynamics in heart failure (HF) both at rest and during exercise. In contrast, little is known about the importance of neurohormonal regulation for exercise capacity in continuous-flow left ventricular assist device (CF-LVAD) patients....... The aim of this study was to assess the relation between neurohormonal activation patterns in CF-LVAD patients and exercise capacity. METHODS: Plasma concentrations of the C-terminal portion of pro-arginine vasopressin precursor (copeptin), pro-adrenomedullin (proADM), pro-B-type (proBNP) and pro......-atrial (proANP) natriuretic peptides were measured in 25 CF-LVAD patients (HeartMate II) in the morning prior to maximal cardiopulmonary exercise testing determining peak oxygen uptake (peak VO2). Quality of life (QOL) was determined by questionnaires. RESULTS: Peak VO2 was severely reduced averaging 13...

  5. Global Bi-ventricular endocardial distribution of activation rate during long duration ventricular fibrillation in normal and heart failure canines.

    Science.gov (United States)

    Luo, Qingzhi; Jin, Qi; Zhang, Ning; Han, Yanxin; Wang, Yilong; Huang, Shangwei; Lin, Changjian; Ling, Tianyou; Chen, Kang; Pan, Wenqi; Wu, Liqun

    2017-04-13

    The objective of this study was to detect differences in the distribution of the left and right ventricle (LV & RV) activation rate (AR) during short-duration ventricular fibrillation (SDVF, 1 min) in normal and heart failure (HF) canine hearts. Ventricular fibrillation (VF) was electrically induced in six healthy dogs (control group) and six dogs with right ventricular pacing-induced congestive HF (HF group). Two 64-electrode basket catheters deployed in the LV and RV were used for global endocardium electrical mapping. The AR of VF was estimated by fast Fourier transform analysis from each electrode. In the control group, the LV was activated faster than the RV in the first 20 s, after which there was no detectable difference in the AR between them. When analyzing the distribution of the AR within the bi-ventricles at 3 min of LDVF, the posterior LV was activated fastest, while the anterior was slowest. In the HF group, a detectable AR gradient existed between the two ventricles within 3 min of VF, with the LV activating more quickly than the RV. When analyzing the distribution of the AR within the bi-ventricles at 3 min of LDVF, the septum of the LV was activated fastest, while the anterior was activated slowest. A global bi-ventricular endocardial AR gradient existed within the first 20 s of VF but disappeared in the LDVF in healthy hearts. However, the AR gradient was always observed in both SDVF and LDVF in HF hearts. The findings of this study suggest that LDVF in HF hearts can be maintained differently from normal hearts, which accordingly should lead to the development of different management strategies for LDVF resuscitation.

  6. Singularity now: using the ventricular assist device as a model for future human-robotic physiology.

    Science.gov (United States)

    Martin, Archer K

    2016-04-01

    In our 21 st century world, human-robotic interactions are far more complicated than Asimov predicted in 1942. The future of human-robotic interactions includes human-robotic machine hybrids with an integrated physiology, working together to achieve an enhanced level of baseline human physiological performance. This achievement can be described as a biological Singularity. I argue that this time of Singularity cannot be met by current biological technologies, and that human-robotic physiology must be integrated for the Singularity to occur. In order to conquer the challenges we face regarding human-robotic physiology, we first need to identify a working model in today's world. Once identified, this model can form the basis for the study, creation, expansion, and optimization of human-robotic hybrid physiology. In this paper, I present and defend the line of argument that currently this kind of model (proposed to be named "IshBot") can best be studied in ventricular assist devices - VAD.

  7. Design and Development of a Miniaturized Percutaneously Deployable Wireless Left Ventricular Assist Device: Early Prototypes and Feasibility Testing.

    Science.gov (United States)

    Letzen, Brian; Park, Jiheum; Tuzun, Zeynep; Bonde, Pramod

    The current left ventricular assist devices (LVADs) are limited by a highly invasive implantation procedure in a severely unstable group of advanced heart failure patients. Additionally, the current transcutaneous power drive line acts as a nidus for infection resulting in significant morbidity and mortality. In an effort to decrease this invasiveness and eliminate drive line complications, we have conceived a wireless miniaturized percutaneous LVAD, capable of being delivered endovascularly with a tether-free operation. The system obviates the need for a transcutaneous fluid purge line required in existing temporary devices by utilizing an incorporated magnetically coupled impeller for a complete seal. The objective of this article was to demonstrate early development and proof-of-concept feasibility testing to serve as the groundwork for future formalized device development. Five early prototypes were designed and constructed to iteratively minimize the pump size and improve fluid dynamic performance. Various magnetic coupling configurations were tested. Using SolidWorks and ANSYS software for modeling and simulation, several geometric parameters were varied. HQ curves were constructed from preliminary in vitro testing to characterize the pump performance. Bench top tests showed no-slip magnetic coupling of the impeller to the driveshaft up to the current limit of the motor. The pump power requirements were tested in vitro and were within the appropriate range for powering via a wireless energy transfer system. Our results demonstrate the proof-of-concept feasibility of a novel endovascular cardiac assist device with the potential to eventually offer patients an untethered, minimally invasive support.

  8. Quality of Life, Depression, and Anxiety in Ventricular Assist Device Therapy: Longitudinal Outcomes for Patients and Family Caregivers.

    Science.gov (United States)

    Bidwell, Julie T; Lyons, Karen S; Mudd, James O; Gelow, Jill M; Chien, Christopher V; Hiatt, Shirin O; Grady, Kathleen L; Lee, Christopher S

    Patients who receive ventricular assist device (VAD) therapy typically rely on informal caregivers (family members or friends) to assist them in managing their device. The purpose of this study is to characterize changes in person-oriented outcomes (quality of life [QOL], depression, and anxiety) for VAD patients and their caregivers together from pre-implantation to 3 months post-implantation. This was a formal interim analysis from an ongoing prospective study of VAD patients and caregivers (n = 41 dyads). Data on person-oriented outcomes (QOL: EuroQol 5 Dimensions Visual Analog Scale; depression: Patient Health Questionnaire-8; anxiety: Brief Symptom Inventory) were collected at 3 time points (just prior to implantation and at 1 and 3 months post-implantation). Trajectories of change for patients and caregivers on each measure were estimated using latent growth modeling with parallel processes. Patients' QOL improved significantly over time, whereas caregiver QOL worsened. Depression and anxiety also improved significantly among patients but did not change among caregivers. There was substantial variability in change on all outcomes for both patients and their caregivers. This is the first quantitative study of VAD patient-caregiver dyads in modern devices that describes change in person-oriented outcomes from pre-implantation to post-implantation. This work supports the need for future studies that account for the inherent relationships between patient and caregiver outcomes and examine variability in patient and caregiver responses to VAD therapy.

  9. Developments in control systems for rotary left ventricular assist devices for heart failure patients: a review.

    Science.gov (United States)

    AlOmari, Abdul-Hakeem H; Savkin, Andrey V; Stevens, Michael; Mason, David G; Timms, Daniel L; Salamonsen, Robert F; Lovell, Nigel H

    2013-01-01

    From the moment of creation to the moment of death, the heart works tirelessly to circulate blood, being a critical organ to sustain life. As a non-stopping pumping machine, it operates continuously to pump blood through our bodies to supply all cells with oxygen and necessary nutrients. When the heart fails, the supplement of blood to the body's organs to meet metabolic demands will deteriorate. The treatment of the participating causes is the ideal approach to treat heart failure (HF). As this often cannot be done effectively, the medical management of HF is a difficult challenge. Implantable rotary blood pumps (IRBPs) have the potential to become a viable long-term treatment option for bridging to heart transplantation or destination therapy. This increases the potential for the patients to leave the hospital and resume normal lives. Control of IRBPs is one of the most important design goals in providing long-term alternative treatment for HF patients. Over the years, many control algorithms including invasive and non-invasive techniques have been developed in the hope of physiologically and adaptively controlling left ventricular assist devices and thus avoiding such undesired pumping states as left ventricular collapse caused by suction. In this paper, we aim to provide a comprehensive review of the developments of control systems and techniques that have been applied to control IRBPs.

  10. Developments in control systems for rotary left ventricular assist devices for heart failure patients: a review

    International Nuclear Information System (INIS)

    AlOmari, Abdul-Hakeem H; Savkin, Andrey V; Lovell, Nigel H; Stevens, Michael; Mason, David G; Timms, Daniel L; Salamonsen, Robert F

    2013-01-01

    From the moment of creation to the moment of death, the heart works tirelessly to circulate blood, being a critical organ to sustain life. As a non-stopping pumping machine, it operates continuously to pump blood through our bodies to supply all cells with oxygen and necessary nutrients. When the heart fails, the supplement of blood to the body's organs to meet metabolic demands will deteriorate. The treatment of the participating causes is the ideal approach to treat heart failure (HF). As this often cannot be done effectively, the medical management of HF is a difficult challenge. Implantable rotary blood pumps (IRBPs) have the potential to become a viable long-term treatment option for bridging to heart transplantation or destination therapy. This increases the potential for the patients to leave the hospital and resume normal lives. Control of IRBPs is one of the most important design goals in providing long-term alternative treatment for HF patients. Over the years, many control algorithms including invasive and non-invasive techniques have been developed in the hope of physiologically and adaptively controlling left ventricular assist devices and thus avoiding such undesired pumping states as left ventricular collapse caused by suction. In this paper, we aim to provide a comprehensive review of the developments of control systems and techniques that have been applied to control IRBPs. (topical review)

  11. Personal digital assistant-based, internet-enabled remote communication system for a wearable pneumatic biventricular assist device.

    Science.gov (United States)

    Nam, Kyoung Won; Lee, Jung Joo; Hwang, Chang Mo; Choi, Seong Wook; Son, Ho Sung; Sun, Kyung

    2007-11-01

    Currently, personal mobile communication devices have become quite common, and the applications of such devices have expanded quickly. Remote communication systems might be employed for the telemonitoring of patients or the operating status of their medical devices. In this article, we describe the development of a mobile-based artificial heart telemanagement system for use in a wearable extracorporeal pneumatic biventricular assist device, which is capable of telemonitoring and telecontrolling the operating status of the ventricular assist device from any site. The system developed herein utilized small mobile phones for the client device and adopted a standard transmission control protocol/Internet protocol communication protocol for the purposes of telecommunication. The results of in vitro and animal experiments showed that the telemanagement system developed herein operated in accordance with the desired parameters.

  12. Validity and reliability of a novel slow cuff-deflation system for noninvasive blood pressure monitoring in patients with continuous-flow left ventricular assist device.

    Science.gov (United States)

    Lanier, Gregg M; Orlanes, Khristine; Hayashi, Yacki; Murphy, Jennifer; Flannery, Margaret; Te-Frey, Rosie; Uriel, Nir; Yuzefpolskaya, Melana; Mancini, Donna M; Naka, Yoshifumi; Takayama, Hiroo; Jorde, Ulrich P; Demmer, Ryan T; Colombo, Paolo C

    2013-09-01

    Doppler ultrasound is the clinical gold standard for noninvasive blood pressure (BP) measurement among continuous-flow left ventricular assist device patients. The relationship of Doppler BP to systolic BP (SBP) and mean arterial pressure (MAP) is uncertain and Doppler measurements require a clinic visit. We studied the relationship between Doppler BP and both arterial-line (A-line) SBP and MAP. Validity and reliability of the Terumo Elemano BP Monitor, a novel slow cuff-deflation device that could potentially be used by patients at home, were assessed. Doppler and Terumo BP measurements were made in triplicate among 60 axial continuous-flow left ventricular assist device (HeartMate II) patients (30 inpatients and 30 outpatients) at 2 separate exams (360 possible measurements). A-line measures were also obtained among inpatients. Mean absolute differences (MADs) and correlations were used to determine within-device reliability (comparison of second and third BP measures) and between-device validity. Bland-Altman plots assessed BP agreement between A-line, Doppler BP, and Terumo Elemano. Success rates for Doppler and Terumo Elemano were 100% and 91%. Terumo Elemano MAD for repeat SBP and MAP were 4.6±0.6 and 4.2±0.6 mm Hg; repeat Doppler BP MAD was 2.9±0.2 mm Hg. Mean Doppler BP was lower than A-line SBP by 4.1 (MAD=6.4±1.4) mm Hg and higher than MAP by 9.5 (MAD=11.0±1.2) mm Hg; Terumo Elemano underestimated A-line SBP by 0.3 (MAD=5.6±0.9) mm Hg and MAP by 1.7 (MAD=6.0±1.0) mm Hg. Doppler BP more closely approximates SBP than MAP. Terumo Elemano was successful, reliable, and valid when compared with A-line and Doppler.

  13. Impact of left ventricular assist device speed adjustment on exercise tolerance and markers of wall stress.

    Science.gov (United States)

    Hayward, Christopher S; Salamonsen, Robert; Keogh, Anne M; Woodard, John; Ayre, Peter; Prichard, Roslyn; Kotlyar, Eugene; Macdonald, Peter S; Jansz, Paul; Spratt, Phillip

    2015-09-01

    Left ventricular assist devices are crucial in rehabilitation of patients with end-stage heart failure. Whether cardiopulmonary function is enhanced with higher pump output is unknown. 10 patients (aged 39±16 years, mean±SD) underwent monitored adjustment of pump speed to determine minimum safe low speed and maximum safe high speed at rest. Patients were then randomized to these speed settings and underwent three 6-minute walk tests (6MWT) and symptom-limited cardiopulmonary stress tests (CPX) on separate days. Pump speed settings (low, normal and high) resulted in significantly different resting pump flows of 4.43±0.6, 5.03±0.94, and 5.72±1.2 l/min (Pexercise (Pexercise time (p=.27). Maximum workload achieved and peak oxygen consumption were significantly different comparing low to high pump speed settings only (Prelease was significantly reduced at higher pump speed with exercise (Prelease consistent with lower myocardial wall stress. This did not, however, improve exercise tolerance.

  14. Risk Stratification of Patients With Current Generation Continuous-Flow Left Ventricular Assist Devices Being Bridged to Heart Transplantation.

    Science.gov (United States)

    Guha, Ashrith; Nguyen, Duc; Cruz-Solbes, Ana S; Amione-Guerra, Javier; Schutt, Robert C; Bhimaraj, Arvind; Trachtenberg, Barry H; Park, Myung H; Graviss, Edward A; Gaber, Osama; Suarez, Erik; Montane, Eva; Torre-Amione, Guillermo; Estep, Jerry D

    Patients bridged to transplant (BTT) with continuous-flow left ventricular assist devices (CF-LVADs) have increased in the past decade. Decision support tools for these patients are limited. We developed a risk score to estimate prognosis and guide decision-making. We included heart transplant recipients bridged with CF-LVADs from the United Network for Organ Sharing (UNOS) database and divided them into development (2,522 patients) and validation cohorts (1,681 patients). Univariate and multivariate Cox proportional hazards models were performed. Variables that independently predicted outcomes (age, African American race, recipient body mass index [BMI], intravenous [IV] antibiotic use, pretransplant dialysis, and total bilirubin) were assigned weight using linear transformation, and risk scores were derived. Patients were grouped by predicted posttransplant mortality: low risk (≤ 38 points), medium risk (38-41 points), and high risk (≥ 42 points). We performed Cox proportional hazards analysis on wait-listed CF-LVAD patients who were not transplanted. Score significantly discriminated survival among the groups in the development cohort (6.7, 12.9, 20.7; p = 0.001), validation cohort (6.4, 10.1, 13.6; p assist device (LVAD) BTT risk score that effectively identifies CF-LVAD patients who are at higher risk for worse outcomes after heart transplant. This score may help physicians weigh the risks of transplantation in patients with CF-LVAD.

  15. Anesthesia for gastrointestinal endoscopy in patients with left ventricular assist devices: Initial experience with 68 procedures

    Directory of Open Access Journals (Sweden)

    Basavana G Goudra

    2013-01-01

    Full Text Available Aims and Objectives: Continuous flow left ventricular assist devices (LVAD have emerged as a reliable treatment option for heart failure. Because of bleeding secondary to anticoagulation, these patients present frequently for gastrointestinal (GI endoscopy. The presently available literature on perioperative management of these patients is extremely limited and is primarily based upon theoretical principles. Materials and Methods: Perioperative records of patients with LVAD undergoing (GI endoscopy between 2008 and 2012 were reviewed. Patient, device and procedure specific information was analyzed. Results: A total of 105 LVADs were implanted, and 68 procedures were performed in 39 patients. The most common indication was GI bleed (48/68, with yearly risk of 8.57% per patient. A total of 63 procedures were performed under deep sedation, with five procedures requiring general anesthesia. Intra-procedure hypotension was managed by fluids and (or vasopressors/inotropes (phenylephrine, ephedrine or milrinone guided by plethysmographic waveform, non-invasive blood pressure (NIBP and LVADs pulsatility index (for HeartMate II/flow pulsatility (for HeartWare. No patient required invasive monitoring and both NIBP and pulse oximeter could be reliably used for monitoring (and guided management in all patients due to the presence of native heart′s pulsatile output. Conclusion: In the presence of residual heart function, with optimal device settings, non-invasive hemodynamic monitoring can be reliably used in these patients while undergoing GI endoscopy under general anesthesia or monitored anesthesia care. Transient hypotensive episodes respond well to fluids/vasopressors without the need of increasing device speed that can be detrimental.

  16. A practical review for cardiac rehabilitation professionals of continuous-flow left ventricular assist devices: historical and current perspectives.

    Science.gov (United States)

    Compostella, Leonida; Russo, Nicola; Setzu, Tiziana; Bottio, Tomaso; Compostella, Caterina; Tarzia, Vincenzo; Livi, Ugolino; Gerosa, Gino; Iliceto, Sabino; Bellotto, Fabio

    2015-01-01

    An increasing number of patients with end-stage heart failure are being treated with continuous-flow left ventricular assist devices (cf-LVADs). These patients provide new challenges to the staff in exercise-based cardiac rehabilitation (CR) programs. Even though experience remains limited, it seems that patients supported by cf-LVADs may safely engage in typical rehabilitative activities, provided that some attention is paid to specific aspects, such as the presence of a short external drive line. In spite of initial physical deconditioning, CR allows progressive improvement of symptoms such as fatigue and dyspnea. Intensity of rehabilitative activities should ideally be based on measured aerobic capacity and increased appropriately over time. Regular, long-term exercise training results in improved physical fitness and survival rates. Appropriate adjustment of cf-LVAD settings, together with maintenance of adequate blood volume, provides maximal output, while avoiding suction effects. Ventricular arrhythmias, although not necessarily constituting an immediate life-threatening situation, deserve treatment as they could lead to an increased rate of hospitalization and poorer quality of life. Atrial fibrillation may worsen symptoms of right ventricular failure and reduce exercise tolerance. Blood pressure measurements are possible in cf-LVAD patients only using a Doppler technique, and a mean blood pressure ≤80 mmHg is considered "ideal." Some patients may present with orthostatic intolerance, related to autonomic dysfunction. While exercise training constitutes the basic rehabilitative tool, a comprehensive intervention that includes psychological and social support could better meet the complex needs of patients in which cf-LVAD may offer prolonged survival.

  17. Flow visualization of three-dimensionality inside the 12 cc Penn State pulsatile pediatric ventricular assist device.

    Science.gov (United States)

    Roszelle, Breigh N; Deutsch, Steven; Manning, Keefe B

    2010-02-01

    In order to aid the ongoing concern of limited organ availability for pediatric heart transplants, Penn State has continued development of a pulsatile Pediatric Ventricular Assist Device (PVAD). Initial studies of the PVAD observed an increase in thrombus formation due to differences in flow field physics when compared to adult sized devices, which included a higher degree of three-dimensionality. This unique flow field brings into question the use of 2D planar particle image velocimetry (PIV) as a flow visualization technique, however the small size and high curvature of the PVAD make other tools such as stereoscopic PIV impractical. In order to test the reliability of the 2D results, we perform a pseudo-3D PIV study using planes both parallel and normal to the diaphragm employing a mock circulatory loop containing a viscoelastic fluid that mimics 40% hematocrit blood. We find that while the third component of velocity is extremely helpful to a physical understanding of the flow, particularly of the diastolic jet and the development of a desired rotational pattern, the flow data taken parallel to the diaphragm is sufficient to describe the wall shear rates, a critical aspect to the study of thrombosis and design of such pumps.

  18. Biventricular assist using a portable driver in combination with implanted devices: preliminary experience.

    Science.gov (United States)

    von Segesser, L K; Tkebuchava, T; Leskosek, B; Marty, B; Pei, Y C; Turina, M

    1997-01-01

    Left ventricular assist systems with portable drive units are increasingly used in the clinical setting. However, such systems usually are not suitable for right ventricular support, and therefore, in the case of biventricular heart failure, they must be combined with other support devices that require additional drive consoles. As a result, most of the benefits of the wearable drive units (early mobilization and outpatient care) are lost. This present study was performed to evaluate biventricular support with implanted assist devices and a portable DC/battery-powered driver (Thoratec TLC-II). Electronic control by nonvolatile RAM accessible via RS232 interface, internal backup emergency battery, and optional manual activation are additional features of this 6 kg biventricular drive unit. In 3 bovine experiments (body weight 70 +/- 5 kg) partial cardiopulmonary bypass (CPB) was established, and two ventricular assist devices were implanted into a preperitoneal pocket on each side after connection to the right atrium and the pulmonary artery and to the left atrium and aorta, respectively. After weaning the patient from CPB, activated coagulation time (ACT) was kept at greater than 180 s, and biventricular support with the portable driver was activated. After 10 min, mean device flow stabilized at 3.5 +/- 0 L/min and remained at that level throughout the ensuing 6 h (3.5 +/- 0.3 L/min; NS). The heart rate moved from 130 +/- 13 beats per minute (bpm) at the end of CPB to 116 +/- 13 bpm after 10 min of assist (p < 0.05). Right atrial pressure moved from 11 +/- 2 mm Hg at the end of CPB to 13 +/- 3 mm Hg after 10 min of assist (not significant [NS]). Mean pulmonary artery pressure was 18 +/- mm Hg at the end of CPB and 17 +/- 5 mm Hg after 10 min of assist (NS). Left atrial pressure was 10 +/- 1 mm Hg at the end of CPB and 13 +/- 3 mm Hg after 10 min of assist (NS). Mean aortic pressure was 73 +/- 11 mm Hg at the end of CPB and 77 +/- 3 mm Hg after 10 min of assist (NS

  19. The Effect of Preoperative Cognitive Behavior and Exercise Therapy for a Patient With an Implanted Left Ventricular Assist Device in Korea.

    Science.gov (United States)

    Seo, Yong Gon; Park, Won Hah; Jeon, Eun Seok; Sung, Ji Dong; Jang, Mi Ja

    2017-10-01

    Left ventricular assist devices (LVADs) are used in patients with progressive heart failure symptoms to provide circulatory support. Patients with LVADs are referred to inpatient cardiac rehabilitation to prevent postoperative complications and improve aerobic capacity and quality of life. Preoperative exercise therapy for cardiac patients is an emerging treatment modality, and several studies have reported that it improves postoperative outcomes, such as length of hospital stay and postoperative complications. This case report describes the benefits of preoperative cognitive behavioral and exercise therapy in a Korean patient undergoing LVAD implantation. V. Copyright © 2017 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  20. The pharmacotherapy of the HeartMate II, a continuous flow left ventricular assist device, in patients with advanced heart failure: integration of disease, device, and drug.

    Science.gov (United States)

    Jennings, Douglas L; Chambers, Rachel M; Schillig, Jessica M

    2010-10-01

    Advanced heart failure continues to be a significant cause of morbidity and mortality in the US. Patients with advanced heart failure have a poor prognosis without cardiac transplantation. The use of left ventricular assist devices (LVADs) as destination therapy for these patients is therefore expected to increase in the coming years as technology advances. The HeartMate II, a continuous flow implantable device, is currently the only LVAD that has been approved by the Food and Drug Administration for destination therapy in patients with advanced heart failure. The pharmacotherapy associated with this device is very complex and, therefore, the need for expertly trained clinical pharmacists to care for this expanding patient population will also likely increase. Unfortunately, most pharmacists are unfamiliar with the effect of LVADs on the physiology and pharmacotherapy of a patient's heart failure. The purpose of this article is to give clinical pharmacists an introduction to the most common pharmacotherapeutic issues for patients with LVADs and present practical solutions for managing common drug therapy problems.

  1. Impact of long term left ventricular assist device therapy on donor allocation in cardiac transplantation.

    Science.gov (United States)

    Uriel, Nir; Jorde, Ulrich P; Woo Pak, Sang; Jiang, Jeff; Clerkin, Kevin; Takayama, Hiroo; Naka, Yoshifumi; Schulze, P Christian; Mancini, Donna M

    2013-02-01

    Left Ventricular Assist Devices (LVAD) are increasingly used as a bridge to transplant (BTT) for patients with advanced congestive heart failure (CHF) and are assigned United Network for Organ Sharing (UNOS) high priority status (1B or 1A). The purpose of our study was asses the effect of organ allocation in the era of continuous flow pumps. A retrospective chart review was performed of all patients transplanted between 1/2001-1/2011 at Columbia University Medical Center. Seven hundred twenty six adult heart transplantations were performed. Two hundred seventy four BTT patients were implanted with LVAD; of which 227 patients were transplanted. Sixty three patients were transplanted as UNOS-1B, while 164 were transplanted as UNOS-1A (72%). Of these 164 patients, 65 were transplanted during their 30-day 1A period (43%) and 96 after upgrading to UNOS-1A for device complication (56%). For 452 non-device patients 139 (31%) were transplanted as UNOS-1A, 233 as UNOS-1B (52%), and 80 as UNOS-2 (17%). The percentage of patients bridged with LVAD increased from 19% in 2001 to 64% in 2010 while the number transplanted during their 30 day 1A grace period declined from 57% in 2005 to 16% in 2011; i.e. 84% of BTT patients in 2011 needed more than 30 days 1A time to be transplanted. Most LVAD patients are now transplanted while suffering device complication. There was no difference in post transplant survival between LVAD patients transplanted as UNOS 1B, 1A grace period or for a device complication As wait time for cardiac transplantation increased the percentage of patients being bridged to transplant with an LVAD has increased with the majority of them transplanted in the setting of device complication. Copyright © 2013 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

  2. Optimal Timing of Heart Transplant After HeartMate II Left Ventricular Assist Device Implantation.

    Science.gov (United States)

    Steffen, Robert J; Blackstone, Eugene H; Smedira, Nicholas G; Soltesz, Edward G; Hoercher, Katherine J; Thuita, Lucy; Starling, Randall C; Mountis, Maria; Moazami, Nader

    2017-11-01

    Optimal timing of heart transplantation in patients supported with second-generation left ventricular assist devices (LVADs) is unknown. Despite this, patients with LVADs continue to receive priority on the heart transplant waiting list. Our objective was to determine the optimal timing of transplantation for patients bridged with continuous-flow LVADs. A total of 301 HeartMate II LVADs (Thoratec Corp, Pleasanton, CA) were implanted in 285 patients from October 2004 to June 2013, and 86 patients underwent transplantation through the end of follow-up. Optimal transplantation timing was the product of surviving on LVAD support and surviving transplant. Three-year survival after both HeartMate II implantation and heart transplantation was unchanged when transplantation occurred within 9 months of implantation. Survival decreased as the duration of support exceeded this. Preoperative risk factors for death on HeartMate II support were prior valve operation, prior coronary artery bypass grafting, low albumin, low glomerular filtration rate, higher mean arterial pressure, hypertension, and earlier date of implant. Survival for patients without these risk factors was lowest when transplant was performed within 3 months but was relatively constant with increased duration of support. Longer duration of support was associated with poorer survival for patients with many of these risk factors. Device reimplantation, intracranial hemorrhage, and postimplant dialysis during HeartMate II support were associated with decreased survival. Survival of patients supported by the HeartMate II is affected by preoperative comorbidities and postoperative complications. Transplantation before complications is imperative in optimizing survival. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  3. Predictors of changes in health status between and within patients 12 months post left ventricular assist device implantation

    DEFF Research Database (Denmark)

    Brouwers, Corline; de Jonge, Nicolaas; Caliskan, Kadir

    2014-01-01

    improvements in health status between baseline and 3 months follow-up as assessed by the KCCQ (clinical summary score: F = 33.49, P physical component score: F = 31.59, P ... 3 months and 12 months follow-up (P > 0.05 for all). Higher scores on anxiety and depression over time, older age, lower ejection fraction, and more co-morbidity were associated with poorer health status scores on one or both of the KCCQ and SF-12 subscales. The majority of the between......BACKGROUND: Improving patient-reported outcomes (e.g. health status) has become an important goal in left ventricular assist device (LVAD) therapy, in addition to reducing mortality and morbidity. We examined predictors of changes in health status scores between and within patients 12 months post...

  4. Performance of Noninvasive Assessment in the Diagnosis of Right Heart Failure After Left Ventricular Assist Device.

    Science.gov (United States)

    Joly, Joanna M; El-Dabh, Ashraf; Marshell, Ramey; Chatterjee, Arka; Smith, Michelle G; Tresler, Margaret; Kirklin, James K; Acharya, Deepak; Rajapreyar, Indranee N; Tallaj, José A; Pamboukian, Salpy V

    2018-06-01

    Right heart failure (RHF) after left ventricular assist device (LVAD) is associated with poor outcomes. Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) defines RHF as elevated right atrial pressure (RAP) plus venous congestion. The purpose of this study was to examine the diagnostic performance of the noninvasive INTERMACS criteria using RAP as the gold standard. We analyzed 108 patients with LVAD who underwent 341 right heart catheterizations (RHC) between January 1, 2006, and December 31, 2013. Physical exam, echocardiography, and laboratory data at the time of RHC were collected. Conventional two-by-two tables were used and missing data were excluded. The noninvasive INTERMACS definition of RHF is 32% sensitive (95% CI, 0.21-0.44) and 97% specific (95% CI, 0.95-0.99) for identifying elevated RAP. Clinical assessment failed to identify two-thirds of LVAD patients with RAP > 16 mm Hg. More than half of patients with elevated RAP did not have venous congestion, which may represent a physiologic opportunity to mitigate the progression of disease before end-organ damage occurs. One-quarter of patients who met the noninvasive definition of RHF did not actually have elevated RAP, potentially exposing patients to unnecessary therapies. In practice, if any component of the INTERMACS definition is present or equivocal, our data suggest RHC is warranted to establish the diagnosis.

  5. Magnetic suspension of the rotor of a ventricular assist device of mixed flow type.

    Science.gov (United States)

    Horikawa, Oswaldo; de Andrade, Aron José Pazin; da Silva, Isaías; Bock, Eduardo Guy Perpetuo

    2008-04-01

    This work presents results of preliminary studies concerning application of magnetic bearing in a ventricular assist device (VAD) being developed by Dante Pazzanese Institute of Cardiology-IDPC (São Paulo, Brazil). The VAD-IDPC has a novel architecture that distinguishes from other known VADs. In this, the rotor has a conical geometry with spiral impellers, showing characteristics that are intermediate between a centrifugal VAD and an axial VAD. The effectiveness of this new type of blood pumping principle was showed by tests and by using it in heart surgery for external blood circulation. However, the developed VAD uses a combination of ball bearings and mechanical seals, limiting the life for some 10 h, making impossible its long-term use or its use as an implantable VAD. As a part of development of an implantable VAD, this work aims at the replacement of ball bearings by a magnetic bearing. The most important magnetic bearing principles are studied and the magnetic bearing developed by Escola Politécnica of São Paulo University (EPUSP-MB) is elected because of its very simple architecture. Besides presenting the principle of the EPUSP-MB, this work presents one possible alternative for applying the EPUSP-MB in the IDPC-VAD.

  6. Palliative medicine consultation for preparedness planning in patients receiving left ventricular assist devices as destination therapy.

    Science.gov (United States)

    Swetz, Keith M; Freeman, Monica R; AbouEzzeddine, Omar F; Carter, Kari A; Boilson, Barry A; Ottenberg, Abigale L; Park, Soon J; Mueller, Paul S

    2011-06-01

    To assess the benefit of proactive palliative medicine consultation for delineation of goals of care and quality-of-life preferences before implantation of left ventricular assist devices as destination therapy (DT). We retrospectively reviewed the cases of patients who received DT between January 15, 2009, and January 1, 2010. Of 19 patients identified, 13 (68%) received proactive palliative medicine consultation. Median time of palliative medicine consultation was 1 day before DT implantation (range, 5 days before to 16 days after). Thirteen patients (68%) completed advance directives. The DT implantation team and families reported that preimplantation discussions and goals of care planning made postoperative care more clear and that adverse events were handled more effectively. Currently, palliative medicine involvement in patients receiving DT is viewed as routine by cardiac care specialists. Proactive palliative medicine consultation for patients being considered for or being treated with DT improves advance care planning and thus contributes to better overall care of these patients. Our experience highlights focused advance care planning, thorough exploration of goals of care, and expert symptom management and end-of-life care when appropriate.

  7. A Novel Mean-Value Model of the Cardiovascular System Including a Left Ventricular Assist Device.

    Science.gov (United States)

    Ochsner, Gregor; Amacher, Raffael; Schmid Daners, Marianne

    2017-06-01

    Time-varying elastance models (TVEMs) are often used for simulation studies of the cardiovascular system with a left ventricular assist device (LVAD). Because these models are computationally expensive, they cannot be used for long-term simulation studies. In addition, their equilibria are periodic solutions, which prevent the extraction of a linear time-invariant model that could be used e.g. for the design of a physiological controller. In the current paper, we present a new type of model to overcome these problems: the mean-value model (MVM). The MVM captures the behavior of the cardiovascular system by representative mean values that do not change within the cardiac cycle. For this purpose, each time-varying element is manually converted to its mean-value counterpart. We compare the derived MVM to a similar TVEM in two simulation experiments. In both cases, the MVM is able to fully capture the inter-cycle dynamics of the TVEM. We hope that the new MVM will become a useful tool for researchers working on physiological control algorithms. This paper provides a plant model that enables for the first time the use of tools from classical control theory in the field of physiological LVAD control.

  8. Enhancement of Arterial Pressure Pulsatility by Controlling Continuous-Flow Left Ventricular Assist Device Flow Rate in Mock Circulatory System.

    Science.gov (United States)

    Bozkurt, Selim; van de Vosse, Frans N; Rutten, Marcel C M

    Continuous-flow left ventricular assist devices (CF-LVADs) generally operate at a constant speed, which reduces pulsatility in the arteries and may lead to complications such as functional changes in the vascular system, gastrointestinal bleeding, or both. The purpose of this study is to increase the arterial pulse pressure and pulsatility by controlling the CF-LVAD flow rate. A MicroMed DeBakey pump was used as the CF-LVAD. A model simulating the flow rate through the aortic valve was used as a reference model to drive the pump. A mock circulation containing two synchronized servomotor-operated piston pumps acting as left and right ventricles was used as a circulatory system. Proportional-integral control was used as the control method. First, the CF-LVAD was operated at a constant speed. With pulsatile-speed CF-LVAD assistance, the pump was driven such that the same mean pump output was generated. Continuous and pulsatile-speed CF-LVAD assistance provided the same mean arterial pressure and flow rate, while the index of pulsatility increased significantly for both arterial pressure and pump flow rate signals under pulsatile speed pump support. This study shows the possibility of improving the pulsatility of CF-LVAD support by regulating pump speed over a cardiac cycle without reducing the overall level of support.

  9. In vivo evaluation of zirconia ceramic in the DexAide right ventricular assist device journal bearing.

    Science.gov (United States)

    Saeed, Diyar; Shalli, Shanaz; Fumoto, Hideyuki; Ootaki, Yoshio; Horai, Tetsuya; Anzai, Tomohiro; Zahr, Roula; Horvath, David J; Massiello, Alex L; Chen, Ji-Feng; Dessoffy, Raymond; Catanese, Jacquelyn; Benefit, Stephen; Golding, Leonard A R; Fukamachi, Kiyotaka

    2010-06-01

    Zirconia is a ceramic with material properties ideal for journal bearing applications. The purpose of this study was to evaluate the use of zirconium oxide (zirconia) as a blood journal bearing material in the DexAide right ventricular assist device. Zirconia ceramic was used instead of titanium to manufacture the DexAide stator housing without changing the stator geometry or the remaining pump hardware components. Pump hydraulic performance, journal bearing reliability, biocompatibility, and motor efficiency data of the zirconia stator were evaluated in six chronic bovine experiments for 14-91 days and compared with data from chronic experiments using the titanium stator. Pump performance data including average in vivo pump flows and speeds using a zirconia stator showed no statistically significant difference to the average values for 16 prior titanium stator in vivo studies, with the exception of a 19% reduction in power consumption. Indices of hemolysis were comparable for both stator types. Results of coagulation assays and platelet aggregation tests for the zirconia stator implants showed no device-induced increase in platelet activation. Postexplant evaluation of the zirconia journal bearing surfaces showed no biologic deposition in any of the implants. In conclusion, zirconia ceramic can be used as a hemocompatible material to improve motor efficiency while maintaining hydraulic performance in a blood journal bearing application.

  10. Discontinuation of antithrombotic therapy for a year or more in patients with continuous-flow left ventricular assist devices.

    Science.gov (United States)

    Pereira, Naveen L; Chen, Dong; Kushwaha, Sudhir S; Park, Soon J

    2010-10-01

    The recommended anticoagulation regimen during continuous-flow axial left ventricular assist device (LVAD) support is aspirin and warfarin with a targeted international normalized ratio of 2.0-3.0. We report two patients in whom recurrent gastrointestinal bleeding during LVAD support necessitated discontinuation of this anti-thrombotic regimen for a year or more. Despite this, neither patients developed thrombotic complications during 29 patient-months of follow-up. An acquired von Willebrand factor (VWF) abnormality reflected by the absence or decreased abundance of the highest molecular weight multimers was demonstrated in both patients. The gold standard test for platelet function, light transmission platelet aggregometry was measured in one patient and was normal, indicative that the predominant abnormality in the coagulation profile of these patients is an acquired VWF syndrome. Clinical trials are required to address the question whether it is safe to discontinue anticoagulation in LVAD patients with acquired VWF abnormalities.

  11. Sex and intimacy among patients with implantable left-ventricular assist devices.

    Science.gov (United States)

    Marcuccilli, Linda; Casida, Jesus Jessie; Peters, Rosalind M; Wright, Susan

    2011-01-01

    Left-ventricular assist devices (LVADs) sustain and improve the quality of life of people living with an advanced stage of heart failure. Past research focused on the development and advancement of LVAD technology, complications, and survival rates. Limited research addressed the psychosocial aspects of living with an LVAD, yet research related to sexual functioning and intimacy is lacking. The purpose of this study was to explore and describe sex and intimacy among adults living with an LVAD. We used an interpretive phenomenological study to explore the experiences of adults living with a long-term implantable LVAD, including the effect of the LVAD on their intimate and sexual functioning. Semistructured interviews were conducted with 7 men and 2 women, 31 to 70 years of age, who had lived with the LVAD at home for at least 3 months. Interviews were audiorecorded and transcribed. The wholistic and selective approach by van Manen (Researching Lived Experience: Human Science for an Action Sensitive Pedagogy. Albany, NY: SUNY Press; 1990) guided the analysis and interpretation of the transcribed interviews. Data were organized and coded into words and phrases using qualitative software. Three themes emerged from the data: (a) improved sexual relations with LVAD, (b) sexual adjustment, and (c) nonsexual intimacy. The themes identified were consistent with the concept of normalcy from the theory of self-care. Participants reported that as the LVAD improved their overall health, their sexual functioning also improved. Participants also reported an increased sense of connectedness and intimacy with their partners even in the absence of sexual intercourse. Participants discussed ways in which they continued to develop intimate relationships even in the presence of limitations in structural and functional integrity. The knowledge derived from this study can be used as a guide for healthcare providers in counseling LVAD recipients on psychosocial and sexual health essential

  12. Implant Strategy-Specific Changes in Symptoms in Response to Left Ventricular Assist Devices.

    Science.gov (United States)

    Lee, Christopher S; Gelow, Jill M; Chien, Christopher V; Hiatt, Shirin O; Bidwell, Julie T; Denfeld, Quin E; Grady, Kathleen L; Mudd, James O

    Although we know that the quality of life generally improves after left ventricular assist device (LVAD) implantation, we know little about how symptoms change in response to LVAD. The purpose of this study was to compare the changes in symptoms between bridge and destination therapy patients as part of a prospective cohort study. Physical (dyspnea and wake disturbances) and affective symptoms (depression and anxiety) were measured before LVAD and at 1, 3, and 6 months after LVAD. Multiphase growth modeling was used to capture the 2 major phases of change: initial improvements between preimplant and 1 month after LVAD and subsequent improvements between 1 and 6 months after LVAD. The sample included 64 bridge and 22 destination therapy patients as the preimplant strategy. Destination patients had worse preimplant dyspnea and wake disturbances, and they experienced greater initial improvements in these symptoms compared with bridge patients (all P .05). Destination patients had worse preimplant depression (P = .042) but experienced similar initial and subsequent improvements in depression in response to LVAD compared with bridge patients (both P > .05). Destination patients had similar preimplant anxiety (P = .279) but experienced less initial and greater subsequent improvements in anxiety after LVAD compared with bridge patients (both P < .05). There are many differences in the magnitude and timing of change in symptom responses to LVAD between bridge and destination therapy patients. Detailed information on changes in specific symptoms may better inform shared decision-making regarding LVAD.

  13. Right ventricular dysfunction following continuous flow left ventriccular assist device placement in 51 patients: predicators and outcomes

    Directory of Open Access Journals (Sweden)

    Neragi-Miandoab Siyamek

    2012-06-01

    Full Text Available Abstract Background Right ventricular (RV dysfunction following implantation of a left ventricular assist device (LVAD is a serious condition and is associated with increased mortality. Methods The aim of the study is to investigate the significance of pre-existing RV dysfunction, tricuspid valve (TV insufficiency, and the severity of septal deviation following LVAD implantation on RV dysfunction, as well as the outcome and short-term complications in 51 patients from June 2006 to August 2010. Student t test was used to compare the data and estimate the p value. Results Mean age was 55.1 ± 13, with a male to female ratio of 3.25. The 30-day mortality was 13.7% (7/51 patients, and the overall mortality was 23.5% (12/51 patients. Meanwhile, 21 patients (21/51; 41.2% have undergone orthotopic heart transplantation. The mean time of support was 314.5±235 days with a median of 240 days at the time of closing this study. Echocardiographic evaluation of RV function pre- and post-implantation of an LVAD demonstrated septal deviation towards the left ventricle in immediate postoperative phase, which correlated with acute RV dysfunction (p = 0.002. Preoperative RV dysfunction was a significant predictor of postoperative right heart dysfunction following implantation of an LVAD (p = 0.001. Conclusion Preoperative RV dysfunction is a predictor of RV failure in LVAD patients. The adjustment of septal deviation through gradual increase of the LVAD flow can prevent the acute RV dysfunction following LVAD placement.

  14. Left ventricular assist device (lvad design features: literature review

    Directory of Open Access Journals (Sweden)

    Yu. V. Bogdanova

    2014-01-01

    Full Text Available More than 8 million people in our country suffer from heart failure. About one million of these people die each year [1]. The problem of ventricular assist device creating - a mechanical device used for partial or complete replacement of heart function - is investigated for a long time (according to [2] just in our country since the 1970s. Today plenty of encouraging results are received. There is a number of VAD models which are successfully applied to patients with heart failure. After implantation, patients conduct a way of life that is normal in many respects: they are in the family, often they have an opportunity to work in their former specialty. Some of them live with the device about 8 years [3].According to [4] for 2010 the estimated total number of long-term devices implanted in the United States per year is over 1,700 (the population of the U.S. is 305 million, compared with over 430 per year in Europe (the population of Europe is 731 million. Unfortunately, people who need a heart transplant are much more.The principle of VAD is that being connected to the left ventricle with one cannula and to the ascending aorta with the other cannula the pump fully or partially replaces the function of the natural heart. This scheme allows the use of VAD in two ways: as a "bridge to transplantation" when the device is used temporarily until the donor heart is found, and a "bridge to recovery", when through the use of VAD the function of the heart muscle is recovered.VAD system can be divided into three subsystems: blood pump, power supply system and control system (Fig. 1.Each subsystem can be the subject of separate study. Special role in the development of VAD plays medical side of the issue. Successful research and development require interaction with qualified professionals in this field. The development of VAD is a multidisciplinary problem which demands fulfilment of a number of requirements.One of the most active programs in implantation of

  15. Exercise guidelines for inpatients following ventricular assist device placement: a systematic review of the literature.

    Science.gov (United States)

    Scheiderer, Rachel; Belden, Courtney; Schwab, Darla; Haney, Casey; Paz, Jaime

    2013-06-01

    For patients with end-stage heart failure awaiting transplantation, lack of donor organs has created an increased need for alternatives such as left ventricular assist device (LVAD) implantation. The purpose of this study is to determine safe and effective exercise parameters for physical therapy in the acute care setting. A systematic literature review was conducted according to PRISMA guidelines using Sackett's Levels of Evidence to rate the evidence. Multiple databases were searched with inclusion criteria of: available in English, inpatient care up to 6 months postoperatively, description of intervention type and exercise parameters. no defined exercise parameters, outpatient treatment, infection post VAD, or palliative or hospice care post VAD. Six studies out of 1,291 articles met inclusion criteria. Common exercise parameters used were the Borg Rating of Perceived Exertion scale 11-13 (6-20 scale) or > 4 (0-10 scale), Dyspnea scale > 2 (0-4 scale) and > 5 (0-10 scale), mean arterial pressure (MAP) 70-95 mmHg, and LVAD flow > 3L/min. Levels of evidence ranged from case controlled to expert opinion. Current evidence on inpatient exercise parameters for patient's status post LVAD implantation is not sufficient to suggest definitive guidelines; however, these exercise parameters provide a reference for patient care.

  16. Myocardial changes in patients with end-stage heart failure during continuous flow left ventricular assist device support

    NARCIS (Netherlands)

    Lok, S.I.

    2013-01-01

    With respect to the clinical outcome, cf-LVADs provide sufficient ventricular unloading and circulatory support. The post-operative mortality and morbidity in our centre are comparable with other recent experiences with this device. Based on these data, Heart Mate II (HM II) LVAD therapy can be

  17. Impact of Vice President Cheney on public interest in left ventricular assist devices and heart transplantation.

    Science.gov (United States)

    Pandey, Ambarish; Abdullah, Kazeen; Drazner, Mark H

    2014-05-01

    Although celebrity illnesses attract a significant amount of media attention in the United States, there are few studies that have looked at how celebrity health conditions impact the awareness of the illness in the general population. Recently, Vice President Cheney underwent left ventricular assist device (LVAD) implantation and subsequently a cardiac transplant. The aim of this study was to determine whether there was evidence of increased interest in these 2 procedures as assessed by social media. We determined the relative frequency of Google searches for LVAD and heart transplantation from 2004 to 2013 using Google trends. We also counted the number of YouTube videos and Twitter messages posted monthly concerning LVADs over a 7-year time frame. There was a significant spike in the Google search interest for LVAD and heart transplantation in the month when Vice President Cheney underwent the respective procedure. Similarly, there was a large increase in YouTube videos and Twitter messages concerning LVADs shortly after he was implanted. In total, these data support the concept that a public figure's illness can significantly influence the public's interest in that condition and its associated therapies. Copyright © 2014 Elsevier Inc. All rights reserved.

  18. Improving hemodynamics of cardiovascular system under a novel intraventricular assist device support via modeling and simulations.

    Science.gov (United States)

    Zhu, Shidong; Luo, Lin; Yang, Bibo; Li, Xinghui; Wang, Xiaohao

    2017-12-01

    Ventricular assist devices (LVADs) are increasingly recognized for supporting blood circulation in heart failure patients who are non-transplant eligible. Because of its volume, the traditional pulsatile device is not easy to implant intracorporeally. Continuous flow LVADs (CF-LVADs) reduce arterial pulsatility and only offer continuous flow, which is different from physiological flow, and may cause long-term complications in the cardiovascular system. The aim of this study was to design a new pulsatile assist device that overcomes this disadvantage, and to test this device in the cardiovascular system. Firstly, the input and output characteristics of the new device were tested in a simple cardiovascular mock system. A detailed mathematical model was established by fitting the experimental data. Secondly, the model was tested in four pathological cases, and was simulated and coupled with a fifth-order cardiovascular system and a new device model using Matlab software. Using assistance of the new device, we demonstrated that the left ventricle pressure, aortic pressure, and aortic flow of heart failure patients improved to the levels of a healthy individual. Especially, in state IV level heart failure patients, the systolic blood pressure increased from 81.34 mmHg to 132.1 mmHg, whereas the diastolic blood pressure increased from 54.28 mmHg to 78.7 mmHg. Cardiac output increased from 3.21 L/min to 5.16 L/min. The newly-developed assist device not only provided a physiological flow that was similar to healthy individuals, but also effectively improved the ability of the pathological ventricular volume. Finally, the effects of the new device on other hemodynamic parameters are discussed.

  19. Association between cell-derived microparticles and adverse events in patients with nonpulsatile left ventricular assist devices.

    Science.gov (United States)

    Nascimbene, Angelo; Hernandez, Ruben; George, Joggy K; Parker, Anita; Bergeron, Angela L; Pradhan, Subhashree; Vijayan, K Vinod; Civitello, Andrew; Simpson, Leo; Nawrot, Maria; Lee, Vei-Vei; Mallidi, Hari R; Delgado, Reynolds M; Dong, Jing Fei; Frazier, O H

    2014-05-01

    Continuous-flow left ventricular assist devices (LVADs) expose blood cells to high shear stress, potentially resulting in the production of microparticles that express phosphatidylserine (PS+) and promote coagulation and inflammation. In this prospective study, we attempted to determine whether PS+ microparticle levels correlate with clinical outcomes in LVAD-supported patients. We enrolled 20 patients undergoing implantation of the HeartMate II LVAD (Thoratec Corp, Pleasanton, CA) and 10 healthy controls who provided reference values for the microparticle assays. Plasma was collected before LVAD implantation, at discharge, at the 3-month follow-up, and when an adverse clinical event occurred. We quantified PS+ microparticles in the plasma using flow cytometry. During the study period, 8 patients developed adverse clinical events: ventricular tachycardia storm in 1, non-ST-elevation myocardial infarction in 2, arterial thrombosis in 2, gastrointestinal bleeding in 2, and stroke in 3. Levels of PS+ microparticles were higher in patients at baseline than in healthy controls (2.11% ± 1.26% vs 0.69% ± 0.46%, p = 0.007). After LVAD implantation, patient PS+ microparticle levels increased to 2.39% ± 1.22% at discharge and then leveled to 1.97% ± 1.25% at the 3-month follow-up. Importantly, levels of PS+ microparticles were significantly higher in patients who developed an adverse event than in patients with no events (3.82% ± 1.17% vs 1.57% ± 0.59%, p microparticle levels may be associated with adverse clinical events. Thus, measuring PS+ microparticle levels in LVAD-supported patients may help identify patients at increased risk for adverse events. Copyright © 2014 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

  20. A numerical method to enhance the performance of a cam-type electric motor-driven left ventricular assist device.

    Science.gov (United States)

    Huang, Huan; Yang, Ming; Lu, Cunyue; Xu, Liang; Zhuang, Xiaoqi; Meng, Fan

    2013-10-01

    Pulsatile left ventricular assist devices (LVADs) driven by electric motors have been widely accepted as a treatment of heart failure. Performance enhancement with computer assistance for this kind of LVAD has seldom been reported. In this article, a numerical method is proposed to assist the design of a cam-type pump. The method requires an integrated model of an LVAD system, consisting of a motor, a transmission mechanism, and a cardiovascular circulation. Performance indices, that is, outlet pressure, outlet flow, and pump efficiency, were used to select the best cam profile from six candidates. A prototype pump connected to a mock circulatory loop (MCL) was used to calibrate the friction coefficient of the cam groove and preliminarily evaluate modeling accuracy. In vitro experiments show that the mean outlet pressure and flow can be predicted with high accuracy by the model, and gross geometries of the measurements can also be reproduced. Simulation results demonstrate that as the total peripheral resistance (TPR) is fixed at 1.1 mm Hg.s/mL, the two-cycle 2/3-rise profile is the best. Compared with other profiles, the maximum increases of pressure and flow indices are 75 and 76%, respectively, and the maximum efficiency increase is over 51%. For different TPRs (0.5∼1.5 mm Hg.s/mL) and operation intervals (0.1∼0.4 s) in counterpulsation, the conclusion is also acceptable. © 2013 Wiley Periodicals, Inc. and International Center for Artificial Organs and Transplantation.

  1. Ventricular Assist Device implant (AB 5000 prototype cannula: In vitro assessment of MRI issues at 3-Tesla

    Directory of Open Access Journals (Sweden)

    Valencerina Samuel

    2008-05-01

    Full Text Available Abstract Purpose To evaluate MRI issues at 3-Tesla for a ventricular assist device (VAD. Methods The AB5000 Ventricle with a prototype Nitinol wire-reinforced In-Flow Cannula and Out-Flow Cannula attached (Abiomed, Inc., Danvers, MA was evaluated for magnetic field interactions, heating, and artifacts at 3-Tesla. MRI-related heating was assessed with the device in a gelled-saline-filled, head/torso phantom using a transmit/received RF body coil while performing MRI at a whole body averaged SAR of 3-W/kg for 15-min. Artifacts were assessed for the main metallic component of this VAD (atrial cannula using T1-weighted, spin echo and gradient echo pulse sequences. Results The AB5000 Ventricle with the prototype In-Flow Cannula and Out-Flow Cannula attached showed relatively minor magnetic field interactions that will not cause movement in situ. Heating was not excessive (highest temperature change, +0.8°C. Artifacts may create issues for diagnostic imaging if the area of interest is in the same area or close to the implanted metallic component of this VAD (i.e., the venous cannula. Conclusion The results of this investigation demonstrated that it would be acceptable for a patient with this VAD (AB5000 Ventricle with a prototype Nitinol wire-reinforced In-Flow Cannula and Out-Flow Cannula attached to undergo MRI at 3-Tesla or less. Notably, it is likely that the operation console for this device requires positioning a suitable distance (beyond the 100 Gauss line or in the MR control room from the 3-Tesla MR system to ensure proper function of the VAD.

  2. Comparison of total artificial heart and biventricular assist device support as bridge-to-transplantation.

    Science.gov (United States)

    Cheng, Allen; Trivedi, Jaimin R; Van Berkel, Victor H; Massey, H Todd; Slaughter, Mark S

    2016-10-01

    The use of left ventricular assist devices (LVAD) has increased significantly in the last decade. However, right heart dysfunction remains a problem despite the improved outcomes with continuous-flow LVADs. Surgical options for bridge to transplantation (BTT) in patients with biventricular failure are total artificial heart (TAH) or biventricular support (BiVAD). This study examines the differences in pre- and post-transplantation outcomes and survival in patients with TAH or BiVAD support as BTT. The United Network of Organ Sharing database was retrospectively queried from January 2005 to December 2014 to identify adult patients undergoing heart transplantation (n = 17,022). Patients supported with either TAH (n = 212) or BiVAD (n = 366) at the time of transplantation were evaluated. Pre- and post-transplantation Kaplan-Meier survival curves were examined. Cox regression model was used to study the hazard ratios of the association between TAH versus BiVAD support and post-transplant survival. The median age of the study groups was 49.8 ± 12.9 (TAH) and 47.2 ± 13.9 (BiVAD) years (range 18-74 years). There were more men, 87% versus 74%, in the TAH group (p < 0.0001) with greater body mass index, 27.3 ± 5.2 versus 25.6 ± 4.7 (p < 0.0001), compared to those with BiVADs. Creatinine was higher, 1.7 + 1.2 versus 1.3 + 0.8 mg/dL (p < 0.0001), in the TAH group before transplant. The 30-day, one-, and three-year post-transplantation survival was 88%, 78%, and 67%, respectively, for patients with TAH support versus 93%, 83%, and 73% (p = 0.06) for patients with BiVAD support. Cox regression model shows pre-transplant creatinine (HR = 1.21, p = 0.008) is associated with a lower post-transplant survival. TAH is not associated with a worse post-transplant survival (p = 0.1). There was no difference in wait-list survival in patients supported with TAH or BiVAD (p = 0.8). Although there has been a recent

  3. When withdrawal of life-sustaining care does more than allow death to take its course: the dilemma of left ventricular assist devices.

    Science.gov (United States)

    Bramstedt, K A; Wenger, N S

    2001-05-01

    Left ventricular assist devices (LVADs) are a relatively new technology that is increasingly used to preserve cardiac function. These devices work by a mechanism that may complicate ethical decision-making for patients who subsequently lose decision-making capacity and are no longer considered transplant candidates. Using a clinical case from our medical center, we explored the complex ethical issues associated with the discontinuation of LVAD therapy by discussing how this device is distinct from the withdrawal of other treatments. While halting an implanted LVAD may permit a patient to die, the deactivated device itself may contribute to patient death due to the potential for blood backflow and pooling, as well as the disruption of heart contractility. Inadequate informed consent and failure to appoint a surrogate decision-maker in advance of the implant procedure resulted in a complex ethical dilemma for the patient's family and the medical team. Clinicians and families must consider the benefits and burdens of LVAD therapy as they do when considering removal of other life-sustaining treatment. The informed consent process associated with LVADs as bridging technology should include extensive consideration of the purpose of the device, future circumstances in which it may be halted, and how such situations would be recognized and handled. Appointment of a surrogate decision-maker before the surgical procedure is essential.

  4. Sodium citrate-assisted anion exchange strategy for construction of Bi2O2CO3/BiOI photocatalysts

    International Nuclear Information System (INIS)

    Song, Peng-Yuan; Xu, Ming; Zhang, Wei-De

    2015-01-01

    Highlights: • Heterostructured Bi 2 O 2 CO 3 /BiOI microspheres were prepared via anion exchange. • Sodium citrate-assisted anion exchange for construction of composite photocatalysts. • Bi 2 O 2 CO 3 /BiOI composites show high visible light photocatalytic activity. - Abstract: Bi 2 O 2 CO 3 /BiOI heterojuncted photocatalysts were constructed through a facile partial anion exchange strategy starting from BiOI microspheres and urea with the assistance of sodium citrate. The content of Bi 2 O 2 CO 3 in the catalysts was regulated by modulating the amount of urea as a precursor, which was decomposed to generate CO 3 2− in the hydrothermal process. Citrate anion plays a key role in controlling the morphology and composition of the products. The Bi 2 O 2 CO 3 /BiOI catalysts display much higher photocatalytic activity than pure BiOI and Bi 2 O 2 CO 3 towards the degradation of rhodamine B (RhB) and bisphenol A (BPA). The enhancement of photocatalytic activity of the heterojuncted catalysts is attributed to the formation of p–n junction between p-BiOI and n-Bi 2 O 2 CO 3 , which is favorable for retarding the recombination of photoinduced electron-hole pairs. Moreover, the holes are demonstrated to be the main active species for the degradation of RhB and BPA

  5. Development of a compact wearable pneumatic drive unit for a ventricular assist device.

    Science.gov (United States)

    Homma, Akihiko; Taenaka, Yoshiyuki; Tatsumi, Eisuke; Akagawa, Eiki; Lee, Hwansung; Nishinaka, Tomohiro; Takewa, Yoshiaki; Mizuno, Toshihide; Tsukiya, Tomonori; Kakuta, Yukihide; Katagiri, Nobumasa; Shimosaki, Isao; Hamada, Shigeru; Mukaibayashi, Hiroshi; Iwaoka, Wataru

    2008-01-01

    The purpose of this study was to develop a compact wearable pneumatic drive unit for a ventricular assist device (VAD). This newly developed drive unit, 20 x 8.5 x 20 cm in size and weighing approximately 1.8 kg, consists of a brushless DC motor, noncircular gears, a crankshaft, a cylinder-piston, and air pressure regulation valves. The driving air pressure is generated by the reciprocating motion of the piston and is controlled by the air pressure regulation valves. The systolic ratio is determined by the noncircular gears, and so is fixed for a given configuration. As a result of an overflow-type mock circulation test, a drive unit with a 44% systolic ratio connected to a Toyobo VAD blood pump with a 70-ml stroke volume achieved a pump output of more than 7 l/min at 100 bpm against a 120 mmHg afterload. Long-term animal tests were also performed using drive units with systolic ratios of 45% and 53% in two Holstein calves weighing 62 kg and 74 kg; the tests were terminated on days 30 and 39, respectively, without any malfunction. The mean aortic pressure, bypass flow, and power consumption for the first calf were maintained at 90 x 13 mmHg, 3.9 x 0.9 l/min, and 12 x 1 W, and those for the second calf were maintained at 88 x 13 mmHg, 5.0 x 0.5 l/min, and 16 x 2 W, respectively. These results indicate that the newly developed drive unit may be used as a wearable pneumatic drive unit for the Toyobo VAD blood pump.

  6. Trends in the Management of Patients With Left Ventricular Assist Devices Presenting for Noncardiac Surgery: A 10-Year Institutional Experience.

    Science.gov (United States)

    Stone, Marc; Hinchey, Joseph; Sattler, Christopher; Evans, Adam

    2016-09-01

    In our institution, the vast majority of patients presenting for noncardiac surgery (NCS) while supported by a left ventricular assist device (LVAD) are now cared for by noncardiac-trained anesthesiologists as the result of a decade of educational intervention to effect this transition. This represents a significant departure from the published experiences of other institutions. With institutional review board approval, we queried the database of our anesthesia record keeping system (CompuRecord) to determine various aspects of the perioperative management of these patients from July 1, 2003, through June 30, 2013, during which time 271 NCS procedures were performed on adult patients supported by LVADs. Over the entire study period (2003-2013), anesthetic care was provided by a cardiac anesthesiologist 47% of the time and by a noncardiac anesthesiologist 53% of the time. However, by the time period 2012-2013, 88% of the NCS procedures were staffed by a noncardiac anesthesiologist. Despite the prevalence of continuous flow devices in this series, the use of invasive blood pressure monitoring decreased dramatically by the later years of the study. Vasoactive and inotropic medications were rarely required intraoperatively. No intraoperative cardiac arrests, thromboembolic complications, or device malfunctions occurred. Our conclusion is that NCS procedures on LVAD-supported patients can be safely managed by educated noncardiac anesthesiologists. © The Author(s) 2015.

  7. Modification of self-concept in patients with a left-ventricular assist device: an initial exploration.

    Science.gov (United States)

    Marcuccilli, Linda; Casida, Jesus; Peters, Rosalind M

    2013-09-01

    To explore how patients with left-ventricular assist devices (LVAD) meet the health-deviation requisite of modifying self-concept to accept this form of treatment and restore normalcy. LVAD are becoming a standard option to improve the quality of life for patients with advanced heart failure. Past research focused on technology issues and survival rates, but limited research has addressed the effect of LVADs on patients' perceptions of self. Orem's theory of self-care provides a framework to investigate how patients manage threats to self-concept to safely live with such a device. Hermeneutic phenomenology based on van Manen's method. Data were collected using semi-structured interviews. Data saturation was achieved with nine participants (seven men; two women), 31-70 years of age who lived with a LVAD at home for at least three months. Thematic analysis was ongoing, and final themes were consensually validated. Two themes constructed from the data were consistent with the requisite of modifying self-concept. First, Having a LVAD means living. Participants described they 'feel alive again', and they 'had the rest of [their] lives that they didn't have before'. The second theme: A desire to be 'normal' in public, arose from participants descriptions of how the LVAD brought unwanted attention to them and that their appearance was 'shocking' to others. Participants accepted the LVAD as necessary to live making it easier for them to modify their self-concept and accept the changes to their bodies and daily lives. Attaining a sense of normalcy was more difficult in public and required additional lifestyle modifications. Findings advance self-care knowledge in LVAD management and can heighten nurses' awareness about self-concept as a vital component for maintenance of health and well-being. © 2013 Blackwell Publishing Ltd.

  8. Prologue: ventricular assist devices and total artificial hearts. A historical perspective.

    Science.gov (United States)

    Frazier, O H

    2003-02-01

    In the 1960s, when LVADs and TAHs were introduced into clinical use, researchers estimated that, with this technology, the problem of heart failure could be solved within 20 years. Unfortunately, the evolution of these devices has taken much longer than anticipated. Nevertheless, significant advances have been achieved in both cardiac assistance and replacement, and today's cardiac surgeons have a wide range of devices from which to choose (Table 4). This progress has largely been due to the support of the NHLBI, especially the Devices and Technology Division headed by John Watson, and of the devoted commitment of the investigators. Because of the long-term commitment required for both basic and clinical research, commercial medical technology companies are unable to assume this burden. Advances in mechanical circulatory support and replacement have benefited numerous patients worldwide who would otherwise have died of heart failure, and devices now exist for use as bridges to recovery, bridges to transplant, and destination therapy. The current challenge is to refine what we have and to apply these technologies to broader patient populations with maximal safety and at a reasonable cost.

  9. Exertional Angina Due To Fused Aortic Bioprosthesis During Left Ventricular Assist Device Support: Two Cases and Review of the Literature.

    Science.gov (United States)

    Bonios, Michael J; Selzman, Craig H; Gilbert, Edward M; McKellar, Stephen H; Koliopoulou, Antigoni; Strege, Jennifer L; Nativi, Jose N; Fang, James C; Stehlik, Josef; Drakos, Stavros G

    We present the case of two patients with idiopathic dilated cardiomyopathy and moderate aortic valve regurgitation that were treated with a bioprosthetic valve at the time of the left ventricular assist device (LVAD) implantation. A few months later, patients revealed partial recovery in the left ventricle systolic function. Both patients, during the LVAD turndown protocol, reported the onset of chest pain. The transthoracic echocardiography revealed the presence of a new transaortic pressure gradient. We confirmed the presence of a fused bioprosthetic valve by further performing a transesophageal echocardiogram and a left and right heart catheterization. Replacement of aortic valve at the time of an LVAD implantation constitutes a challenging case. Although a mechanical valve is contraindicated due to the increased thromboembolic risk, selecting a bioprosthetic valve increases the risk of valve leaflets fusion. The consequences of this phenomenon should be acknowledged in LVAD patients undergoing aortic valve replacement with a bioprosthetic, especially under the view of LVAD explantation for those revealing myocardial recovery under mechanical unloading.

  10. The effect of ventricular assist devices on cerebral blood flow and blood pressure fractality

    International Nuclear Information System (INIS)

    Bellapart, Judith; Fraser, John F; Chan, Gregory S H; Tzeng, Yu-Chieh; Ainslie, Philip N; Dunster, Kimble R; Barnett, Adrian G; Boots, Rob

    2011-01-01

    Biological signals often exhibit self-similar or fractal scaling characteristics which may reflect intrinsic adaptability to their underlying physiological system. This study analysed fractal dynamics of cerebral blood flow in patients supported with ventricular assist devices (VAD) to ascertain if sustained modifications of blood pressure waveform affect cerebral blood flow fractality. Simultaneous recordings of arterial blood pressure and cerebral blood flow velocity using transcranial Doppler were obtained from five cardiogenic shock patients supported by VAD, five matched control patients and five healthy subjects. Computation of a fractal scaling exponent (α) at the low-frequency time scale by detrended fluctuation analysis showed that cerebral blood flow velocity exhibited 1/f fractal scaling in both patient groups (α = 0.95 ± 0.09 and 0.97 ± 0.12, respectively) as well as in the healthy subjects (α = 0.86 ± 0.07). In contrast, fluctuation in blood pressure was similar to non-fractal white noise in both patient groups (α = 0.53 ± 0.11 and 0.52 ± 0.09, respectively) but exhibited 1/f scaling in the healthy subjects (α = 0.87 ± 0.04, P < 0.05 compared with the patient groups). The preservation of fractality in cerebral blood flow of VAD patients suggests that normal cardiac pulsation and central perfusion pressure changes are not the integral sources of cerebral blood flow fractality and that intrinsic vascular properties such as cerebral autoregulation may be involved. However, there is a clear difference in the fractal scaling properties of arterial blood pressure between the cardiogenic shock patients and the healthy subjects

  11. Right heart failure and "failure to thrive" after left ventricular assist device: clinical predictors and outcomes.

    Science.gov (United States)

    Baumwol, Jay; Macdonald, Peter S; Keogh, Anne M; Kotlyar, Eugene; Spratt, Phillip; Jansz, Paul; Hayward, Christopher S

    2011-08-01

    This study determined predictors of early post-operative right heart failure (RHF) and its consequences, as well as predictors of those who clinically thrive longer term after insertion of a continuous-flow left ventricular assist device (LVAD). Pre-operative and latest follow-up data were analyzed for 40 consecutive patients who received third-generation centrifugal-flow LVADs. RHF was defined using previously described criteria, including post-operative inotropes, pulmonary vasodilator use, or right-sided mechanical support. Patients were also categorized according to clinical outcomes after LVAD insertion. LVADs were implanted as a bridge to transplantation (BTT) in 33 patients and as destination therapy in 7. Before LVAD implant, 22 patients were Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) level 1, and 17 were at level 2. Temporary mechanical assistance was present in 50% of the cohort at LVAD implantation. The 6-month survival/progression to transplant was 92.5%. Average LVAD support time was 385 days (range, 21-1,011 days). RHF developed postoperatively in 13 of 40 patients (32.5%). RHF patients had more severe pre-operative tricuspid incompetence than non-RHF patients. The BTT patients with evidence of RHF had poorer survival to transplant (6 of 11 [54.5%]) than those without RHF (20 of 22 [90.9%]), p = 0.027). There were no other hemodynamic or echocardiographic predictors of short-term RHF. After LVAD, 22 of the 40 patients (55%) thrived clinically. For BTT patients, 20 of 21 (95%) of those who thrived progressed to transplant or were alive at latest follow-up vs 6 of 12 (50%) of those who failed to thrive (FTT; p thrived. Early post-operative RHF results in poorer survival/progression to transplantation for BTT patients and is predicted by greater pre-operative tricuspid incompetence. The most important predictor for those who will clinically thrive longer-term after LVAD insertion is younger age. Crown Copyright © 2011

  12. Hepatic and renal function with successful long-term support on a continuous flow left ventricular assist device.

    Science.gov (United States)

    Deo, Salil V; Sharma, Vikas; Altarabsheh, Salah E; Hasin, Tal; Dillon, John; Shah, Ishan K; Durham, Lucian A; Stulak, John M; Daly, Richard C; Joyce, Lyle D; Park, Soon J

    2014-03-01

    Data regarding the long-term clinical effects of a continuous flow left ventricular assist device (CF-LVAD) on hepato-renal function is limited. Hence our aim was to assess changes in hepato-renal function over a one-year period in patients supported on a CF-LVAD. During the study period 126 patients underwent CF-LVAD implant. Changes in hepato-renal laboratory parameters were studied in 61/126 patients successfully supported on a CF-LVAD for period of one year. A separate cohort of a high-risk group (HCrB) of patients (56/126) with a serum creat>1.9 mg/dL (168 μmol/L) (75th percentile) or a serum bil>1.5 mg/dL (25.65 μmol/L) (75th percentile) was created. Changes in serum creatinine and bilirubin were analysed at regular intervals for this group along with the need for renal replacement therapy. Baseline creatinine and blood urea nitrogen (BUN) for the entire cohort was 1.4[1.2,1.9 mg/dL] [123.7(106,168) μmol/L) and 27[20,39.5 mg/dL] [9.6(7.1,14.1) mmol/L] respectively. After an initial reduction at the end of one month [1(0.8,1.2) mg/dL; 88(70,105) μmol/L] (passist device support for one year. High-risk patients demonstrate a higher 30-day mortality and temporary need for renal replacement therapy. Yet even in this cohort, improvement is present over a period of one year on the device, with a minimal need for permanent haemodialysis. Copyright © 2013 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.

  13. Postoperative B-Type Natriuretic Peptide as Predictor for Postoperative Outcomes in Patients Implanted With Left Ventricular Assist Devices.

    Science.gov (United States)

    Yost, Gardner; Bhat, Geetha; Pappas, Patroklos; Tatooles, Antone

    2018-04-18

    Brain natriuretic peptide (BNP) is a cardiac neurohormone known to correlate with left ventricular (LV) dilation, decreased contractility, and increased stiffness. Consequently, BNP has been used as a prognostic tool to assess the degree of LV unloading for patients supported by continuous-flow LV assist devices (LVADs). We assessed the prognostic value of changes in BNP in the 2 weeks after LVAD implantation. This retrospective study analyzed laboratory findings and outcomes of 189 LVAD patients. Patients were separated into two groups based on whether serum BNP levels had improved from preoperative levels by postoperative day 14. Group 1 had improvement in BNP levels, whereas group 2 had no improvement or worsening in BNP. There were no significant differences between the groups in age, gender, race, body mass index, or comorbidities. Group 1 had preoperative BNP 1,125 ± 1,078.3 pg/dl and postoperative BNP 440.2 ± 267.7 pg/dl (ΔBNP = -693.09 ± 942.4 pg/dl), whereas group 2 had preoperative BNP 346.0 ± 309.1 pg/dl and postoperative BNP 631.57 ± 483.4 pg/dl (ΔBNP = 289.32 ± 329.7 pg/dl). Postoperative survival in group 2 was significantly worse than in group 1. Rates of right ventricular failure (RVF) were significantly higher in group 2 (group 1: 39%, group 2: 52.7%; p = 0.01). In most patients implanted with a LVAD, BNP improves significantly in the postoperative period as the LV is unloaded. Our results indicate that lack of improvement in postoperative BNP is associated with longer length of stay, increased rates of RVF, and is an independent risk factor for reduced postoperative survival.

  14. Costs and reimbursement gaps after implementation of third-generation left ventricular assist devices.

    Science.gov (United States)

    Mishra, Vinod; Geiran, Odd; Fiane, Arnt E; Sørensen, Gro; Andresen, Sølvi; Olsen, Ellen K; Khushi, Ishtiaq; Hagen, Terje P

    2010-01-01

    The purpose of this study was to compare and contrast total hospital costs and subsequent reimbursement of implementing a new program using a third-generation left ventricular assist device (LVAD) in Norway. Between July 2005 and March 2008, the total costs of treatment for 9 patients were examined. Costs were calculated for three periods-the pre-implantation LVAD phase, the LVAD implantation phase and the post-implantation LVAD phase-as well as for total hospital care. Patient-specific costs were obtained prospectively from patient records and included personnel resources, medication, blood products, blood chemistry and microbiology, imaging, and procedure costs including operating room costs. Overhead costs were registered retrospectively and allocated to the specific patient by pre-defined allocation keys. Finally, patient-specific costs and overhead costs were aggregated into total patient costs. The average total patient cost in 2007 U.S. dollars was $735,342 and the median was $613,087 (range $342,581 to $1,256,026). The mean length of stay was 77 days (range 40 to 127 days). For the LVAD implantation phase, the mean cost was $457,795 and median cost was $458,611 (range $246,239 to $677,680). The mean length of stay for the LVAD implantation phase was 55 days (range 25 to 125 days). The diagnosis-related group (DRG) reimbursement (2007) was $143,192. There is significant discrepancy between actual hospital costs and the current Norwegian DRG reimbursement for the LVAD procedure. This discrepancy can be partly explained by excessive costs related to the introduction of a new program with new technology. Costly innovations should be considered in price setting of reimbursement for novel technology. Copyright (c) 2010 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

  15. Frailty and outcomes after implantation of left ventricular assist device as destination therapy.

    Science.gov (United States)

    Dunlay, Shannon M; Park, Soon J; Joyce, Lyle D; Daly, Richard C; Stulak, John M; McNallan, Sheila M; Roger, Véronique L; Kushwaha, Sudhir S

    2014-04-01

    Frailty is recognized as a major prognostic indicator in heart failure. There has been interest in understanding whether pre-operative frailty is associated with worse outcomes after implantation of a left ventricular assist device (LVAD) as destination therapy. Patients undergoing LVAD implantation as destination therapy at the Mayo Clinic, Rochester, Minnesota, from February 2007 to June 2012, were included in this study. Frailty was assessed using the deficit index (31 impairments, disabilities and comorbidities) and defined as the proportion of deficits present. We divided patients based on tertiles of the deficit index (>0.32 = frail, 0.23 to 0.32 = intermediate frail, <0.23 = not frail). Cox proportional hazard regression models were used to examine the association between frailty and death. Patients were censored at death or last follow-up through October 2013. Among 99 patients (mean age 65 years, 18% female, 55% with ischemic heart failure), the deficit index ranged from 0.10 to 0.65 (mean 0.29). After a mean follow-up of 1.9 ± 1.6 years, 79% of the patients had been rehospitalized (range 0 to 17 hospitalizations, median 1 per person) and 45% had died. Compared with those who were not frail, patients who were intermediate frail (adjusted HR 1.70, 95% CI 0.71 to 4.31) and frail (HR 3.08, 95% CI 1.40 to 7.48) were at increased risk for death (p for trend = 0.004). The mean (SD) number of days alive out of hospital the first year after LVAD was 293 (107) for not frail, 266 (134) for intermediate frail and 250 (132) for frail patients. Frailty before destination LVAD implantation is associated with increased risk of death and may represent a significant patient selection consideration. Copyright © 2014 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

  16. Pre- and post-operative risk factors associated with cerebrovascular accidents in patients supported by left ventricular assist device. -Single center's experience in japan-.

    Science.gov (United States)

    Nakajima, Ikutaro; Kato, Tomoko S; Komamura, Kazuo; Takahashi, Ayako; Oda, Noboru; Sasaoka, Taro; Asakura, Masanori; Hashimura, Kazuhiko; Kitakaze, Masafumi

    2011-01-01

    Cerebrovascular accident (CVA) is a major adverse event following left ventricular assist device (LVAD) surgery. This study investigates pre- and post-operative factors associated with CVA in this population. A total of 118 consecutive patients who underwent LVAD surgery at our institution between April 1994 and April 2009 were retrospectively reviewed. Clinical characteristics, hemodynamic data, and laboratory indexes associated with CVA after LVAD surgery were analyzed. In total, 57 (48.3%) patients developed CVA 133.5 ± 184.7 days after surgery. The combination of baseline heart disease, type of LVAD surgery, mean right atrial pressure (mRA), serum total bilirubin and total protein concentration, and right ventricular end-diastolic dimension (RVEDd) was associated with CVA at any time after LVAD surgery, with a discriminant probability of 718%. With regard to CVA development later than 3 months after surgery, the combination of mRA and RVEDd before surgery [odds ratio (OR), 1.24, 1.20; 95% confidential interval (CI), 1.07-1.42, 1.06-1.34; P = 0.004, P = 0.006, respectively], positive blood culture, and C-reactive protein after surgery (OR, 7.66, 2.19; 95%CI, 1.50-39.0, 1.47-3.25; P = 0.015, P < 0.0001, respectively) was associated with CVA with a discriminant probability of 85.9%. Patients' general condition including malnutrition, in addition to device selection, contributed to overall CVA development after surgery. In the chronic phase after surgery, pre-LVAD right heart failure and post-LVAD systemic infection were highly associated with CVA development.

  17. A new "twist" on right heart failure with left ventricular assist systems.

    Science.gov (United States)

    Houston, Brian A; Shah, Keyur B; Mehra, Mandeep R; Tedford, Ryan J

    2017-07-01

    Despite significant efforts to predict and prevent right heart failure, it remains a leading cause of morbidity and mortality after implantation of left ventricular assist systems (LVAS). In this Perspective, we review the underappreciated anatomic and physiologic principles that govern the relationship between left and right heart function and contribute to this phenomenon. This includes the importance of considering the right ventricle (RV) and pulmonary arterial circuit as a coupled system; the contribution of the left ventricle (LV) to RV contractile function and the potential negative impact of acutely unloading the LV; the influence of the pericardium and ventricular twist on septal function; the role of RV deformation in reduced mechanical efficiency after device placement; and the potential of ongoing stressors of an elevated right-sided preload. We believe an appreciation of these complex issues is required to fully understand the expression of the unique phenotypes of right heart failure after LVAS implantation and for developing better prognostic and therapeutic strategies. Copyright © 2017 International Society for the Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

  18. Preoperative atrial fibrillation increases risk of thromboembolic events after left ventricular assist device implantation.

    Science.gov (United States)

    Stulak, John M; Deo, Salil; Schirger, John; Aaronson, Keith D; Park, Soon J; Joyce, Lyle D; Daly, Richard C; Pagani, Francis D

    2013-12-01

    Because no series has specifically analyzed the impact of preoperative atrial fibrillation (AF) on patients already at higher risk of thromboembolism after implantation of a left ventricular assist device (LVAD), we review our experience with these patients. Between July 2003 and September 2011, 389 patients (308 male) underwent implantation of a continuous flow LVAD at University of Michigan Hospital and Mayo Clinic. Median age at implant was 60 years (range, 18 to 79 years). Preoperative AF was present in 120 patients (31%). Outcomes were analyzed for the association of preoperative AF and postoperative thromboembolic (TE) events defined as stroke, transient ischemic attack, hemolysis, or pump thrombosis. Thromboembolic events occurring within the first 30 days were not counted. One hundred thirty-eight TEs events occurred in 97/389 patients (25%) for an event rate of 0.31 TE events/patient-years of support. Freedom from a TE event in patients with preoperative AF was 62% at 1 year and 46% at 2 years compared with 79% and 72% at 1 and 2 years, respectively, in patients without preoperative AF (p < 0.001). Median survival was 10 months (maximum 7.2 years, total 439 patient-years). Preoperative AF did not decrease late survival at 1 and 2 years after LVAD implant (preop AF: 85% and 70% versus no preop AF: 82% and 70%, respectively; p = 0.55). Patients with preoperative AF have a lower freedom from TE events after LVAD implant. While overall late survival was not significantly reduced in these patients, refinement in anticoagulation strategies after VAD implant may be required. Copyright © 2013 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  19. Implantable Cardioverter-Defibrillators in Patients With a Continuous-Flow Left Ventricular Assist Device: An Analysis of the INTERMACS Registry.

    Science.gov (United States)

    Clerkin, Kevin J; Topkara, Veli K; Demmer, Ryan T; Dizon, Jose M; Yuzefpolskaya, Melana; Fried, Justin A; Mai, Xingchen; Mancini, Donna M; Takeda, Koji; Takayama, Hiroo; Naka, Yoshifumi; Colombo, Paolo C; Garan, A Reshad

    2017-12-01

    This study sought to determine if the presence of implantable cardioverter-defibrillators (ICD) provided a mortality benefit during continuous-flow left ventricular assist device (LVAD) support. An ICD decreases mortality in selected patients with advanced heart failure and have been associated with reduced mortality in patients with pulsatile LVAD. However, it is unclear whether that benefit extends to patients with a contemporary continuous-flow LVAD. Propensity score matching was used to generate a cohort of patients with similar baseline characteristics. The primary outcome was freedom from death during LVAD support. Secondary endpoints included freedom from unexpected death, likelihood of transplantation and recovery, and adverse events. Among 16,384 eligible patients in the Interagency Registry for Mechanically Assisted Circulatory Support registry, 2,209 patients with an ICD and 2,209 patients without one had similar propensity scores and were included. The presence of an ICD was associated with an increased mortality risk (hazard ratio: 1.20; 95% confidence interval [CI]: 1.04 to 1.39; p = 0.013) and an increased risk of unexpected death during device support (HR: 1.33; 95% CI: 1.03 to 1.71; p = 0.03). Patients with an ICD were more likely to undergo transplantation (HR: 1.16; 95% CI: 0.99 to 1.35; p = 0.06) and less likely to have LVAD explant for recovery (HR: 0.53, 95% CI: 0.29 to 0.98; p = 0.04). Patients with an ICD had a higher rate of treated ventricular arrhythmias (rate ratio: 1.27; 95% CI: 1.10 to 1.48; p = 0.001) and rehospitalization (rate ratio: 1.08; 95% CI: 1.04 to 1.12; p < 0.0001), but rates of hemorrhagic stroke were similar (rate ratio: 1.01; 95% CI: 0.81 to 1.26; p = 0.98). Among patients with a continuous flow LVAD, the presence of an ICD was not associated with reduced mortality. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  20. Epicardial deployment of right ventricular disk during perventricular device closure in a child with apical muscular ventricular septal defect

    Directory of Open Access Journals (Sweden)

    Nageswara Rao Koneti

    2013-01-01

    Full Text Available We report a successful perventricular closure of an apical muscular ventricular septal defect (mVSD by a modified technique. An eight-month-old infant, weighing 6.5 kilograms, presented with refractory heart failure. The transthoracic echocardiogram showed multiple apical mVSDs with the largest one measuring 10 mm. perventricular device closure using a 12 mm Amplatzer mVSD occluder was planned. The left ventricular disk was positioned approximating the interventricular septum; however, the right ventricular (RV disk was deployed on the free wall of the RV due to an absent apical muscular septum and a small cavity at the apex. The RV disk of the device was covered using an autologous pericardium. His heart failure improved during follow-up.

  1. Hexamethylenetetramine assisted hydrothermal synthesis of BiPO4 and its electrochemical properties for supercapacitors

    Science.gov (United States)

    Nithya, V. D.; Kalai Selvan, R.; Vasylechko, Leonid

    2015-11-01

    The well defined microstructures of BiPO4 were successfully synthesized by the facile hexamethylenetetramine (HMT) assisted hydrothermal method. The low temperature monoclinic BiPO4 structure with space group P21/n, were obtained from X-ray diffraction (XRD) for the pristine and HMT-assisted BiPO4 with 1, 3, 5 and 10 mmole concentration. A transformation from low temperature monazite-type phase to the high temperature SbPO4-type phase of BiPO4 was observed at the 10 mmole concentration. There was a variation in the morphology from polyhedron to octahedra-like and finally into cube shape upon an increase in concentration of HMT. The role of reaction time in the morphology of BiPO4 particles was investigated. The selected area electron diffraction (SAED) pattern elucidated the ordered dot pattern and the calculated d-spacing revealed the formation of BiPO4. An increased specific capacitance of HMT assisted materials (202 F/g) compared with pristine BiPO4 (89 F/g) at 5 mA/cm2 was observed upon morphological variation due to HMT addition.

  2. Pulse Oximeter Derived Blood Pressure Measurement in Patients With a Continuous Flow Left Ventricular Assist Device.

    Science.gov (United States)

    Hellman, Yaron; Malik, Adnan S; Lane, Kathleen A; Shen, Changyu; Wang, I-Wen; Wozniak, Thomas C; Hashmi, Zubair A; Munson, Sarah D; Pickrell, Jeanette; Caccamo, Marco A; Gradus-Pizlo, Irmina; Hadi, Azam

    2017-05-01

    Currently, blood pressure (BP) measurement is obtained noninvasively in patients with continuous flow left ventricular assist device (LVAD) by placing a Doppler probe over the brachial or radial artery with inflation and deflation of a manual BP cuff. We hypothesized that replacing the Doppler probe with a finger-based pulse oximeter can yield BP measurements similar to the Doppler derived mean arterial pressure (MAP). We conducted a prospective study consisting of patients with contemporary continuous flow LVADs. In a small pilot phase I inpatient study, we compared direct arterial line measurements with an automated blood pressure (ABP) cuff, Doppler and pulse oximeter derived MAP. Our main phase II study included LVAD outpatients with a comparison between Doppler, ABP, and pulse oximeter derived MAP. A total of five phase I and 36 phase II patients were recruited during February-June 2014. In phase I, the average MAP measured by pulse oximeter was closer to arterial line MAP rather than Doppler (P = 0.06) or ABP (P < 0.01). In phase II, pulse oximeter MAP (96.6 mm Hg) was significantly closer to Doppler MAP (96.5 mm Hg) when compared to ABP (82.1 mm Hg) (P = 0.0001). Pulse oximeter derived blood pressure measurement may be as reliable as Doppler in patients with continuous flow LVADs. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  3. The Heartmate III: design and in vivo studies of a maglev centrifugal left ventricular assist device.

    Science.gov (United States)

    Loree, H M; Bourque, K; Gernes, D B; Richardson, J S; Poirier, V L; Barletta, N; Fleischli, A; Foiera, G; Gempp, T M; Schoeb, R; Litwak, K N; Akimoto, T; Kameneva, M; Watach, M J; Litwak, P

    2001-05-01

    A compact implantable centrifugal left ventricular assist device (LVAD) (HeartMate III) featuring a magnetically levitated impeller is under development. The goal of our ongoing work is to demonstrate feasibility, low hemolysis, and low thrombogenicity of the titanium pump in chronic bovine in vivo studies. The LVAD is based on so-called bearingless motor technology and combines pump rotor, drive, and magnetic bearing functions in a single unit. The impeller is rotated (theta z) and levitated with both active (X, Y) and passive (Z, theta x, theta y) suspension. Six prototype systems have been built featuring an implantable titanium pump (69 mm diameter, 30 mm height) with textured blood contacting surfaces and extracorporeal electronics. The pumps were implanted in 9 calves (< or = 100 kg at implant) that were anticoagulated with Coumadin (2.5 < or = INR < or = 4.0) throughout the studies. Six studies were electively terminated (at 27-61 days), 1 study was terminated after the development of severe pneumonia and lung atelectasis (at 27 days) another study was terminated after cardiac arrest (at 2 days) while a final study is ongoing (at approximately 100 days). Mean pump flows ranged from 2 to 7 L/min, except for brief periods of exercise at 6 to 9 L/min. Plasma free hemoglobin ranged from 4 to 10 mg/dl. All measured biochemical indicators of end organ function remained within normal range. The pumps have met performance requirements in all 9 implants with acceptable hemolysis and no mechanical failures.

  4. Stabilization of metal-oxide bulk switching device with diffused Bi contacts

    International Nuclear Information System (INIS)

    Lalevic, B.; Shoga, M.; Gvishi, M.; Levy, S.; Army ERADCOM, Ft. Monmouth, NJ)

    1979-01-01

    Threshold switching from the high to low resistance state has been investigated in the polycrystalline and single crystal NbO/sub x/ (where x is approximately = 2) metal-oxide devices. Stable and reproducible switching performance is observed in a configuration Bi-NbO 2 -Bi where Bi electrodes were covered with Au films. Improvement in the device performance is attributed to the Bi diffusion into NbO/sub x/ which has been confirmed by the Auger electron spectroscopy. Typical off state resistance of these devices is approx.100 KΩ and threshold switching voltage in the range from 100 to 2500 V. The delay time tau/sub d/ is exponentially dependent on the applied voltage V/sub appl/ and at larger V/sub appl'/ the delay time is less than a nanosecond. Recovery time of a device is approx.0.5 μsec as determined by the method of decreasing time interval between two successive pulses. Holding voltage is approx.40 V. The pulsed switched devices can withstand pulse durations between 0.1 to 3 μsec, repetition rate of 100 C/s and current intensities of 10 to 15 A, or 25 A peak with the applied pulse duration of 20 μsec, single shot

  5. Energy transmission and power sources for mechanical circulatory support devices to achieve total implantability.

    Science.gov (United States)

    Wang, Jake X; Smith, Joshua R; Bonde, Pramod

    2014-04-01

    Left ventricular assist device therapy has radically improved congestive heart failure survival with smaller rotary pumps. The driveline used to power today's left ventricular assist devices, however, continues to be a source of infection, traumatic damage, and rehospitalization. Previous attempts to wirelessly power left ventricular assist devices using transcutaneous energy transfer systems have been limited by restrictions on separation distance and alignment between the transmit and receive coils. Resonant electrical energy transfer allows power delivery at larger distances without compromising safety and efficiency. This review covers the efforts to wirelessly power mechanical circulatory assist devices and the progress made in enhancing their energy sources. Copyright © 2014 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  6. Photocatalytic perfermance of sandwich-like BiVO_4 sheets by microwave assisted synthesis

    International Nuclear Information System (INIS)

    Liu, Suqin; Tang, Huiling; Zhou, Huan; Dai, Gaopeng; Wang, Wanqiang

    2017-01-01

    Graphical abstract: Sandwich-like BiVO_4 sheets were successfully synthesized via a facile microwave-assisted method. The as-prepared samples exhibit a high activity for the degradation of methyl orange under visible light irradiation. - Highlights: • Sandwich-like BiVO_4 sheets were synthesized by a facile microwave-assisted method. • The presence of PEG-10000 plays a critical role in the formation of BiVO_4 sheets. • Ostwald ripening is the primary driving force for the formation of sandwich-like BiVO_4. • The sandwich-like BiVO_4 sheets exhibit a high visible-light photocatalytic activity. - Abstract: Sandwich-like BiVO_4 sheets were successfully synthesized in an aqueous solution containing bismuth nitrate, ammonium metavanadate and polyethylene glycol with a molecular weight of 10,000 (PEG-10000) using a facile microwave-assisted method. The as-prepared samples were characterized by scanning electron microscopy, N_2 adsorption-desorption, X-ray diffraction, X-ray photoelectron spectroscopy (XPS), and UV–vis diffuse reflectance spectroscopy. The results show that the presence of PEG-10000 plays a critical role in the formation of BiVO_4 sheets, and Ostwald ripening is the primary driving force for the formation of sandwich-like structures. The sandwich-like BiVO_4 sheets exhibit a high activity for the degradation of methyl orange under visible light irradiation (λ ≥ 420 nm). The enhancement of photocatalytic activity of sandwich-like BiVO_4 sheets can be attributed to its large surface area over the irregular BiVO_4 particles.

  7. Exploring cognitive bias in destination therapy left ventricular assist device decision making: A retrospective qualitative framework analysis.

    Science.gov (United States)

    Magid, Molly; McIlvennan, Colleen K; Jones, Jaqueline; Nowels, Carolyn T; Allen, Larry A; Thompson, Jocelyn S; Matlock, Dan

    2016-10-01

    Cognitive biases are psychological influences, which cause humans to make decisions, which do not seemingly maximize utility. For people with heart failure, the left ventricular assist device (LVAD) is a surgically implantable device with complex tradeoffs. As such, it represents an excellent model within which to explore cognitive bias in a real-world decision. We conducted a framework analysis to examine for evidence of cognitive bias among people deciding whether or not to get an LVAD. The aim of this study was to explore the influence of cognitive bias on the LVAD decision-making process. We analyzed previously conducted interviews of patients who had either accepted or declined an LVAD using a deductive, predetermined framework of cognitive biases. We coded and analyzed the interviews using an inductive-deductive framework approach, which also allowed for other themes to emerge. We interviewed a total of 22 heart failure patients who had gone through destination therapy LVAD decision making (15 who had accepted the LVAD and 7 who had declined). All patients appeared influenced by state dependence, where both groups described high current state of suffering, but the groups differed in whether they believed LVAD would relieve suffering or not. We found evidence of cognitive bias that appeared to influence decision making in both patient groups, but groups differed in terms of which cognitive biases were present. Among accepters, we found evidence of anchoring bias, availability bias, optimism bias, and affective forecasting. Among decliners, we found evidence of errors in affective forecasting. Medical decision making is often a complicated and multifaceted process that includes cognitive bias as well as other influences. It is important for clinicians to recognize that patients can be affected by cognitive bias, so they can better understand and improve the decision-making process to ensure that patients are fully informed. Published by Elsevier Inc.

  8. A comparison of the health status and psychological distress of partners of patients with a left ventricular assist device versus an implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Brouwers, Corline; Caliskan, Kadir; de Jonge, Nicolaas

    2014-01-01

    (F = 10.71, p = .001) but poorer mental health status (F = 14.82, p depression scores compared to ICD partners (F = 3.68, p = .05) at 6 months follow-up, also in adjusted analyses. There was no significant difference between groups on anxiety. CONCLUSION: Caregivers of LVAD......OBJECTIVE: To examine if the caregiving for patients with a left ventricular assist device (LVAD) is related to a poorer health status and more distress compared to patients with an implantable cardioverter defibrillator (ICD). BACKGROUND: Partners distress may influence patient outcomes...... and is therefore an important aspect in the care of LVAD and ICD patients. METHODS: Multi-center prospective observational study with 6 months follow-up of 33 LVAD partners (27% men; mean age = 54 ± 10 years) and 414 ICD partners (22% men; mean age = 60 ± 12 years). RESULTS: LVAD partners reported better physical...

  9. Using medical imaging for the detection of adverse events ("incidents") during the utilization of left ventricular assist devices in adult patients with advanced heart failure.

    Science.gov (United States)

    Kaufmann, Friedrich; Krabatsch, Thomas

    2016-05-01

    Ventricular assist devices (VAD) are used for mechanical support of the terminally failing heart. Failure of these life supporting systems can be fatal. Early and reliable detection of any upcoming problems is mandatory and is crucial for the outcome. Medical imaging methods are described within this review, which are not only essential for diagnosis of typically VAD-related complications but also for the detection or verification of technical issues. Within this review the utilization of medical imaging equipment for the diagnosis of technical malfunctions or damages of implanted system components is discussed. A newly developed specialized acoustic imaging method for pump thrombosis detection will also be described along with the most common VAD-related medical complications and their respective imaging methods and the limitations induced by the use of the VAD-system.

  10. Identification and Management of Pump Thrombus in the HeartWare Left Ventricular Assist Device System: A Novel Approach Using Log File Analysis.

    Science.gov (United States)

    Jorde, Ulrich P; Aaronson, Keith D; Najjar, Samer S; Pagani, Francis D; Hayward, Christopher; Zimpfer, Daniel; Schlöglhofer, Thomas; Pham, Duc T; Goldstein, Daniel J; Leadley, Katrin; Chow, Ming-Jay; Brown, Michael C; Uriel, Nir

    2015-11-01

    The study sought to characterize patterns in the HeartWare (HeartWare Inc., Framingham, Massachusetts) ventricular assist device (HVAD) log files associated with successful medical treatment of device thrombosis. Device thrombosis is a serious adverse event for mechanical circulatory support devices and is often preceded by increased power consumption. Log files of the pump power are easily accessible on the bedside monitor of HVAD patients and may allow early diagnosis of device thrombosis. Furthermore, analysis of the log files may be able to predict the success rate of thrombolysis or the need for pump exchange. The log files of 15 ADVANCE trial patients (algorithm derivation cohort) with 16 pump thrombus events treated with tissue plasminogen activator (tPA) were assessed for changes in the absolute and rate of increase in power consumption. Successful thrombolysis was defined as a clinical resolution of pump thrombus including normalization of power consumption and improvement in biochemical markers of hemolysis. Significant differences in log file patterns between successful and unsuccessful thrombolysis treatments were verified in 43 patients with 53 pump thrombus events implanted outside of clinical trials (validation cohort). The overall success rate of tPA therapy was 57%. Successful treatments had significantly lower measures of percent of expected power (130.9% vs. 196.1%, p = 0.016) and rate of increase in power (0.61 vs. 2.87, p file parameters can potentially predict the likelihood of successful tPA treatments and if validated prospectively, could substantially alter the approach to thrombus management. Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  11. A difficult decision: what should we do when malignant tumours are diagnosed in patients supported by left ventricular assist devices?

    Science.gov (United States)

    Smail, Hassiba; Pfister, Christian; Baste, Jean-Marc; Nafeh-Bizet, Catherine; Gay, Arnaud; Barbay, Virginie; Bessou, Jean-Paul; Peillon, Christophe; Litzler, Pierre-Yves

    2015-09-01

    Left ventricular assist devices (LVADs) are used as a bridge to heart transplantation. During the preimplantation or pretransplantation screening, malignant tumours can be discovered. Owing to the lack of guidelines, the management is difficult. We describe our perioperative approach and the patients' outcomes. Between 2006 and 2014, 55 patients underwent implantation of HeartMate II LVAD. Five were diagnosed with malignant tumours: 2 renal, 2 lung and 1 breast tumours. The renal tumours were diagnosed during the preimplantation screening. An LVAD was implanted in both followed by partial nephrectomies 8 and 9 months later. The lung cancers were diagnosed after device implantation, a left pulmonary segmentectomy and a right upper sleeve lobectomy were performed. The breast cancer was diagnosed few months after support and a tumourectomy with lymphadenectomy was performed. Tumour resection was performed successfully in all patients. Prior to surgery haemostasis, device and heart function were evaluated. During surgery, haemodynamics and anticoagulation were monitored. Reoperations were necessary to evacuate haemothorax after lobectomy and an abdominal haematoma post-nephrectomy. After discussion with oncologists, 3 patients were relisted for heart transplantation. Two were successfully transplanted 2 and 3 years after partial nephrectomy with an actual survival of 56 and 59 months after the cancer diagnosis. The follow-up revealed no cancer recurrences. Malignant tumours during support with LVAD can be successfully resected. A multidisciplinary evaluation in these high-risk patients is mandatory. After careful evaluation, regaining the patient's heart transplant candidacy is possible. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  12. Metabolic volume performs better than SUVmax in the detection of left ventricular assist device driveline infection

    Energy Technology Data Exchange (ETDEWEB)

    Avramovic, Nemanja; Weckesser, Matthias; Milankovic, Danka; Vrachimis, Alexis; Wenning, Christian [University Hospital Muenster, Department of Nuclear Medicine, Muenster (Germany); Dell' Aquila, Angelo Maria; Sindermann, Juergen R. [University Hospital Muenster, Department of Cardiac Surgery, Muenster (Germany)

    2017-10-15

    A continuous-flow left ventricular assist device (LVAD) is a new and highly promising therapy in supporting end-stage heart failure patients, either bridging them to heart transplantation or as a destination therapy. Infection is one of the major complications associated with LVAD implants. {sup 18}F-FDG PET/CT has already been shown to be useful in the detection of LVAD infection. The goal of this study was to compare the diagnostic accuracy of different PET analysis techniques (visual grading versus SUVmax and metabolic volume). We retrospectively analyzed 48 patients with implanted LVAD who underwent an {sup 18}F-FDG PET/CT that were either suspected to have a driveline or device infection or inflammation of unknown origin. PET/CT was analyzed qualitatively (visual grading) and quantitatively (SUVmax and metabolic volume) and matched to the final clinical diagnosis concerning driveline infection. The final diagnosis (standard of reference) was made at the end of clinically recorded follow-up or transplantation and included microbiological cultures of the driveline exit site and/or surgical samples, and clinical signs of infection despite negative cultures as well as recurrence of symptoms. Sensitivity, specificity, positive and negative predictive value were 87.5%, 79%, 81% and 86% for visual score, 87.5%, 87.5%, 87.5% and 87.5% for SUVmax and 96%, 87.5%, 88.5%, 95.5% for metabolic volume, respectively. ROC analysis revealed an AUC of.929 for SUVmax and.969 for metabolic volume. Both SUVmax and metabolic volume had a high detection rate of patients with driveline infection (21/24 = 91.5% true positive vs. 23/26 = 88.5% true positive, respectively). However, metabolic volume detected more patients without any infection correctly (1/22 = 4.5% false negative vs. 3/24 = 12.5% false negative). {sup 18}F-FDG PET/CT is a valuable tool for the diagnosis of LVAD driveline infection with high diagnostic accuracy. Particularly the use of the metabolic volume yields very

  13. Bi-directional magnetic resonance based wireless power transfer for electronic devices

    International Nuclear Information System (INIS)

    Kar, Durga P.; Nayak, Praveen P.; Bhuyan, Satyanarayan; Mishra, Debasish

    2015-01-01

    In order to power or charge electronic devices wirelessly, a bi-directional wireless power transfer method has been proposed and experimentally investigated. In the proposed design, two receiving coils are used on both sides of a transmitting coil along its central axis to receive the power wirelessly from the generated magnetic fields through strongly coupled magnetic resonance. It has been observed experimentally that the maximum power transfer occurs at the operating resonant frequency for optimum electric load connected across the receiving coils on both side. The optimum wireless power transfer efficiency is 88% for the bi-directional power transfer technique compared 84% in the one side receiver system. By adopting the developed bi-directional power transfer method, two electronic devices can be powered up or charged simultaneously instead of a single device through usual one side receiver system without affecting the optimum power transfer efficiency

  14. Bi-directional magnetic resonance based wireless power transfer for electronic devices

    Energy Technology Data Exchange (ETDEWEB)

    Kar, Durga P.; Nayak, Praveen P.; Bhuyan, Satyanarayan; Mishra, Debasish [Department of Electronics and Instrumentation Engineering, Institute of Technical Education and Research, Siksha ‘O’ Anushandhan University, Bhubaneswar 751030 (India)

    2015-09-28

    In order to power or charge electronic devices wirelessly, a bi-directional wireless power transfer method has been proposed and experimentally investigated. In the proposed design, two receiving coils are used on both sides of a transmitting coil along its central axis to receive the power wirelessly from the generated magnetic fields through strongly coupled magnetic resonance. It has been observed experimentally that the maximum power transfer occurs at the operating resonant frequency for optimum electric load connected across the receiving coils on both side. The optimum wireless power transfer efficiency is 88% for the bi-directional power transfer technique compared 84% in the one side receiver system. By adopting the developed bi-directional power transfer method, two electronic devices can be powered up or charged simultaneously instead of a single device through usual one side receiver system without affecting the optimum power transfer efficiency.

  15. The miRNA Expression Profile in Acute Myocardial Infarct Using Sheep Model with Left Ventricular Assist Device Unloading

    Directory of Open Access Journals (Sweden)

    Xiaoqian Yan

    2017-01-01

    Full Text Available This study attempted to establish miRNA expression profiles in acute myocardial infarct (AMI sheep model with left ventricular assist device (LVAD unloading. AMI was established in sheep model and FW-II type axial flow pump was implanted to maintain continuous unloading for 3 days. The cardiomyocyte survival, inflammatory cell infiltration, and myocardial fibrosis were detected by tissue staining, and cardiomyocyte apoptosis was detected by TUNEL assay. High throughput sequencing technique was used to detect miRNA expression in cardiomyocytes and to establish miRNA expression profile. The Gene Ontology (GO and Kyoto Encyclopedia of Genes and Genomes (KEGG analyses were established. miRNA sequencing results identified 152 known mature miRNAs and 1582 new mature miRNAs. The unloading and control groups differentially expressed genes, of which RT-PCR verified oar-miR-19b and oar-miR-26a. The GO and KEGG pathway annotation and enrichment established that the regulating functions and signaling pathways of these miRNAs were closely related to cardiovascular diseases (CVD. In this study, LVAD effectively reduced the cell death degree of cardiomyocyte in MI. The established miRNA expression profiles of AMI and LVAD intervention in this study suggest that the expression profile could be used to explore the unknown miRNA and the regulatory mechanisms involved in AMI.

  16. Cost-effectiveness of left ventricular assist devices for patients with end-stage heart failure: analysis of the French hospital discharge database.

    Science.gov (United States)

    Tadmouri, Abir; Blomkvist, Josefin; Landais, Cécile; Seymour, Jerome; Azmoun, Alexandre

    2018-02-01

    Although left ventricular assist devices (LVADs) are currently approved for coverage and reimbursement in France, no French cost-effectiveness (CE) data are available to support this decision. This study aimed at estimating the CE of LVAD compared with medical management in the French health system. Individual patient data from the 'French hospital discharge database' (Medicalization of information systems program) were analysed using Kaplan-Meier method. Outcomes were time to death, time to heart transplantation (HTx), and time to death after HTx. A micro-costing method was used to calculate the monthly costs extracted from the Program for the Medicalization of Information Systems. A multistate Markov monthly cycle model was developed to assess CE. The analysis over a lifetime horizon was performed from the perspective of the French healthcare payer; discount rates were 4%. Probabilistic and deterministic sensitivity analyses were performed. Outcomes were quality-adjusted life years (QALYs) and incremental CE ratio (ICER). Mean QALY for an LVAD patient was 1.5 at a lifetime cost of €190 739, delivering a probabilistic ICER of €125 580/QALY [95% confidence interval: 105 587 to 150 314]. The sensitivity analysis showed that the ICER was mainly sensitive to two factors: (i) the high acquisition cost of the device and (ii) the device performance in terms of patient survival. Our economic evaluation showed that the use of LVAD in patients with end-stage heart failure yields greater benefit in terms of survival than medical management at an extra lifetime cost exceeding the €100 000/QALY. Technological advances and device costs reduction shall hence lead to an improvement in overall CE. © 2017 The Authors. ESC Heart Failure published by John Wiley & Sons Ltd on behalf of the European Society of Cardiology.

  17. Totally implantable total artificial heart and ventricular assist device with multipurpose miniature electromechanical energy system.

    Science.gov (United States)

    Takatani, S; Orime, Y; Tasai, K; Ohara, Y; Naito, K; Mizuguchi, K; Makinouchi, K; Damm, G; Glueck, J; Ling, J

    1994-01-01

    A multipurpose miniature electromechanical energy system has been developed to yield a compact, efficient, durable, and biocompatible total artificial heart (TAH) and ventricular assist device (VAD). Associated controller-driver electronics were recently miniaturized and converted into hybrid circuits. The hybrid controller consists of a microprocessor and controller, motor driver, Hall sensor, and commutation circuit hybrids. The sizing study demonstrated that all these components can be incorporated in the pumping unit of the TAH and VAD, particularly in the centerpiece of the TAH and the motor housing of the VAD. Both TAH and VAD pumping units will start when their power line is connected to either the internal power pack or the external battery unit. As a redundant driving and diagnostic port, an emergency port was newly added and will be placed in subcutaneous location. In case of system failure, the skin will be cut down, and an external motor drive or a pneumatic driver will be connected to this port to run the TAH. This will minimize the circulatory arrest time. Overall efficiency of the TAH without the transcutaneous energy transmission system was 14-18% to deliver pump outputs of 4-9 L/min against the right and left afterload pressures of 25 and 100 mm Hg. The internal power requirement ranged from 6 to 13 W. The rechargeable batteries such as NiCd or NiMH with 1 AH capacity can run the TAH for 30-45 min. The external power requirement, when TETS efficiency of 75% was assumed, ranged from 8 to 18 W. The accelerated endurance test in the 42 degrees C saline bath demonstrated stable performance over 4 months. Long-term endurance and chronic animal studies will continue toward a system with 5 years durability by the year 2000.

  18. Risk factors, mortality, and timing of ischemic and hemorrhagic stroke with left ventricular assist devices.

    Science.gov (United States)

    Frontera, Jennifer A; Starling, Randall; Cho, Sung-Min; Nowacki, Amy S; Uchino, Ken; Hussain, M Shazam; Mountis, Maria; Moazami, Nader

    2017-06-01

    Stroke is a major cause of mortality after left ventricular assist device (LVAD) placement. Prospectively collected data of patients with HeartMate II (n = 332) and HeartWare (n = 70) LVADs from October 21, 2004, to May 19, 2015, were reviewed. Predictors of early (during index hospitalization) and late (post-discharge) ischemic and hemorrhagic stroke and association of stroke subtypes with mortality were assessed. Of 402 patients, 83 strokes occurred in 69 patients (17%; 0.14 events per patient-year [EPPY]): early ischemic stroke in 18/402 (4%; 0.03 EPPY), early hemorrhagic stroke in 11/402 (3%; 0.02 EPPY), late ischemic stroke in 25/402 (6%; 0.04 EPPY) and late hemorrhagic stroke in 29/402 (7%; 0.05 EPPY). Risk of stroke and death among patients with stroke was bimodal with highest risks immediately post-implant and increasing again 9-12 months later. Risk of death declined over time in patients without stroke. Modifiable stroke risk factors varied according to timing and stroke type, including tobacco use, bacteremia, pump thrombosis, pump infection, and hypertension (all p hemorrhagic stroke (adjusted odds ratio [aOR] 4.3, 95% confidence interval [CI] 1.0-17.8, p = 0.04), late ischemic stroke (aOR 3.2, 95% CI 1.1-9.0, p = 0.03), and late hemorrhagic stroke (aOR 3.7, 95% CI 1.5-9.2, p = 0.005) predicted death, whereas early ischemic stroke did not. Stroke is a leading cause and predictor of death in patients with LVADs. Risk of stroke and death among patients with stroke is bimodal, with highest risk at time of implant and increasing risk again after 9-12 months. Management of modifiable risk factors may reduce stroke and mortality rates. Copyright © 2017 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

  19. Post-transplant outcomes in pediatric ventricular assist device patients: A PediMACS-Pediatric Heart Transplant Study linkage analysis.

    Science.gov (United States)

    Sutcliffe, David L; Pruitt, Elizabeth; Cantor, Ryan S; Godown, Justin; Lane, John; Turrentine, Mark W; Law, Sabrina P; Lantz, Jodie L; Kirklin, James K; Bernstein, Daniel; Blume, Elizabeth D

    2017-12-13

    Pediatric ventricular assist device (VAD) support as bridge to transplant has improved waitlist survival, but the effects of pre-implant status and VAD-related events on post-transplant outcomes have not been assessed. This study is a linkage analysis between the PediMACS and Pediatric Heart Transplant Study databases to determine the effects of VAD course on post-transplant outcomes. Database linkage between October 1, 2012 and December 31, 2015 identified 147 transplanted VAD patients, the primary study group. The comparison cohort was composed of 630 PHTS patients without pre-transplant VAD support. The primary outcome was post-transplant survival, with secondary outcomes of post-transplant length of stay, freedom from infection and freedom from rejection. At implant, the VAD cohort was INTERMACS Profile 1 in 33 (23%), Profile 2 in 89 (63%) and Profile 3 in 14 (10%) patients. The VAD cohort was older, larger, and less likely to have congenital heart disease (p < 0.0001). However, they had greater requirements for inotrope and ventilator support and increased liver and renal dysfunction (p < 0.0001), both of which normalized at transplant after device support. Importantly, there were no differences in 1-year post-transplant survival (96% vs 93%, p = 0.3), freedom from infection (81% vs 79%, p = 0.9) or freedom from rejection (71% vs 74%, p = 0.87) between cohorts. Pediatric VAD patients have post-transplant outcomes equal to that of medically supported patients, despite greater pre-implant illness severity. Post-transplant survival, hospital length of stay, infection and rejection were not affected by patient acuity at VAD implantation or VAD-related complications. Therefore, VAD as bridge to transplant mitigates severity of illness in children. Copyright © 2017 International Society for the Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

  20. Photocatalytic perfermance of sandwich-like BiVO{sub 4} sheets by microwave assisted synthesis

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Suqin, E-mail: liusuqin888@126.com [Department of Chemical engineering and Food Science, Hubei University of arts and science, Xiangyang 441053 (China); Hubei Key Laboratory of Low Dimensional Optoelectronic Materials and Devices, Xiangyang 441053 (China); Tang, Huiling; Zhou, Huan [Department of Chemical engineering and Food Science, Hubei University of arts and science, Xiangyang 441053 (China); Dai, Gaopeng, E-mail: dgp2000@126.com [Department of Chemical engineering and Food Science, Hubei University of arts and science, Xiangyang 441053 (China); Wang, Wanqiang [Department of Chemical engineering and Food Science, Hubei University of arts and science, Xiangyang 441053 (China)

    2017-01-01

    Graphical abstract: Sandwich-like BiVO{sub 4} sheets were successfully synthesized via a facile microwave-assisted method. The as-prepared samples exhibit a high activity for the degradation of methyl orange under visible light irradiation. - Highlights: • Sandwich-like BiVO{sub 4} sheets were synthesized by a facile microwave-assisted method. • The presence of PEG-10000 plays a critical role in the formation of BiVO{sub 4} sheets. • Ostwald ripening is the primary driving force for the formation of sandwich-like BiVO{sub 4}. • The sandwich-like BiVO{sub 4} sheets exhibit a high visible-light photocatalytic activity. - Abstract: Sandwich-like BiVO{sub 4} sheets were successfully synthesized in an aqueous solution containing bismuth nitrate, ammonium metavanadate and polyethylene glycol with a molecular weight of 10,000 (PEG-10000) using a facile microwave-assisted method. The as-prepared samples were characterized by scanning electron microscopy, N{sub 2} adsorption-desorption, X-ray diffraction, X-ray photoelectron spectroscopy (XPS), and UV–vis diffuse reflectance spectroscopy. The results show that the presence of PEG-10000 plays a critical role in the formation of BiVO{sub 4} sheets, and Ostwald ripening is the primary driving force for the formation of sandwich-like structures. The sandwich-like BiVO{sub 4} sheets exhibit a high activity for the degradation of methyl orange under visible light irradiation (λ ≥ 420 nm). The enhancement of photocatalytic activity of sandwich-like BiVO{sub 4} sheets can be attributed to its large surface area over the irregular BiVO{sub 4} particles.

  1. Study of photocatalytic activities of Bi2WO6 nanoparticles synthesized by fast microwave-assisted method

    International Nuclear Information System (INIS)

    Phu, Nguyen Dang; Hoang, Luc Huy; Chen, Xiang-Bai; Kong, Meng-Hong; Wen, Hua-Chiang; Chou, Wu Ching

    2015-01-01

    We present a study of photocatalytic activities of Bi 2 WO 6 nanoparticles synthesized by fast microwave-assisted method. The photocatalytic activities of the nanoparticles were evaluated by the decolorization of methylene-blue under visible-light-irradiation. Our results show that the surface area of Bi 2 WO 6 nanoparticles plays a major role for improving photocatalytic activity, while visible-light absorption has only a weak effect on photocatalytic activity. This suggests efficient transportation of photo-generated electrons and holes to the oxidation active sites on the surface of nanoparticles, indicating Bi 2 WO 6 nanoparticles synthesized by fast microwave-assisted method are promising for achieving high photocatalytic activity under visible-light-irradiation. - Highlights: • The Bi 2 WO 6 nanoparticles were synthesized via fast microwave-assisted method. • The obtained Bi 2 WO 6 nanoparticles exhibited visible-light absorbance. • The surface area of Bi 2 WO 6 nanoparticles plays major role for improving photocatalytic activity. • The Bi 2 WO 6 nanoparticles are promising for achieving high photocatalytic activity under visible-light-irradiation

  2. Avaliação do desempenho hemodinâmico do dispositivo de assistência ventricular InCor como substituto do coração esquerdo Analysis of the hemodynamic performance of the InCor ventricular assist device as a substitute for the left heart

    Directory of Open Access Journals (Sweden)

    Anderson BENÍCIO

    1999-07-01

    dispositivo foi melhor quanto maior o nível de vácuo no sistema de drenagem e com a utilização de cânula ventricular.BACKGROUND: The mechanical circulatory assistance is a therapeutic option in cases of cardiogenic shock refractory to the pharmacological treatment, and is frequently used as a bridge for heart transplantation. OBJECTIVE: To evaluate the action of the Ventricular Assist Device (VAD developed by the Bioengineering Division of the Instituto do Coração, implanted as a substitute of the left heart. PATIENTS AND METHODS: Ten Girolando calves with medium weight of 73 kg were studied. The VAD-InCor implant was accomplished with the drainage cannula positioned in the left atrium (LA or in the apex of the left ventricle and the replacement cannula implanted in the descending thoracic aorta. The pressures of the right and left heart, cardiac output and the flow of VAD were determined before and after the pharmacological induction of myocardial failure, at different levels of vacuum of the drainage system. RESULTS: Values of the flow of VAD with the drainage in LA were of 2.2 ± 0.5 l/min without vacuum, of 3.7 ± 0.4 with vacuum of 10 mmHg, of 4.3 ± 0.4 with vacuum of 20 mmHg and of 4.8 ± 0.6 with vacuum of 30 mmHg. The values of the pressure of LA were: 11.7 ± 6; 9.8 ± 5.3; 8.5 ± 4.4 and 5.6 ± 3.3 mmHg under the same conditions, respectively. With the ventricular cannula, the VAD flow was 4.2 ± 0.6 without vacuum and of 4.4 ± 0.7 with vacuum of 10 mmHg, with of LA pressure of 11.1 ± 2 and 10.3 ± 3.5 mmHg in the two conditions. Those results were observed in similar hemodynamic conditions, with the VAD flow responsible for a greater percentile of the total cardiac output according to the level of vacuum. That percentile was of 86 ± 13% with the atrial cannula and vacuum of 30 mmHg and of 97 ± 3% with the ventricular drainage and vacuum of 10 mmHg. CONCLUSIONS: The VAD-InCor demonstrated its effectiveness as a substitute of the left heart. The

  3. Processing of magnetically anisotropic MnBi particles by surfactant assisted ball milling

    Energy Technology Data Exchange (ETDEWEB)

    Kanari, K. [Department of Physics, Aristotle University of Thessaloniki, 54124 Thessaloniki (Greece); Sarafidis, C., E-mail: hsara@physics.auth.gr [Department of Physics, Aristotle University of Thessaloniki, 54124 Thessaloniki (Greece); Gjoka, M.; Niarchos, D. [INN, NCSR Demokritos, Athens 15310 (Greece); Kalogirou, O. [Department of Physics, Aristotle University of Thessaloniki, 54124 Thessaloniki (Greece)

    2017-03-15

    MnBi particles are obtained from bulk MnBi using mechanochemical processing. The structure and magnetic properties of the MnBi particles are investigated by means of X-ray diffraction analysis, scanning electron microscopy and magnetometry. Surfactant assisted high energy ball milling results to the samples’ degradation even after one hour of milling. In the case of surfactant assisted low energy ball milling the increase of ball milling duration decreases the average particle size while the particles seem to be more separated. The saturation magnetization (M{sub s}) was found to decrease for large milling times beginning from 61 Am{sup 2}/kg, while the coercivity (μ{sub 0}H{sub c}) increases with the increase of ball milling duration up to 35 min where it reaches 1.62 T and thereafter it decreases. - Highlights: • Effect of surfactants in processing of MnBi. • Magnetization degradation due to air storage and due to processing. • Coercivity of 1.6 T in epoxy resin oriented material.

  4. De novo aortic insufficiency during long-term support on a left ventricular assist device: a systematic review and meta-analysis.

    Science.gov (United States)

    Deo, Salil V; Sharma, Vikas; Cho, Yang Hyun; Shah, Ishan K; Park, Soon J

    2014-01-01

    Aortic insufficiency (AI) may occur while supported on a left ventricular assist device (LVAD). We conducted a systematic review to determine the incidence, predictors, and consequences of AI during LVAD support. MEDLINE was searched for original studies presenting clinical data regarding patients who developed AI during LVAD implant. Seven observational studies (657 patients) were selected for review; 65% of patients underwent implantation with a continuous-flow device (Cf-LVAD). The incidence of AI was 25% (11-42%) (Support period: 412 ± 281 days). AI increased by 4% (1-6%) per month of support (p < 0.01). AI-positive patients were older at implant (weighted mean difference, 7.7 [4.3; 11.1]; p < 0.01). Female sex (0.002 ± 0.001; p = 0.01) and smaller body surface area (-0.003 ± 0.001 per m; p < 0.01) correlated with progressive AI. Destination therapy patients (odds ratio [OR], 5.3 [1.2, 24]; p = 0.02) and those with Cf-LVAD pumps were likely to develop AI (hazard ratio [HR], 2.2 [1.2, 3.8]; p < 0.01). A closed aortic valve was associated with AI (OR, 4.7 [1.9, 11.8]; p < 0.01). Survival was comparable in both cohorts (HR, 1.5 [0.81, 2.8]; p = 0.2). A significant number of patients develop de novo AI during LVAD support. Advanced age, longer support duration, continuous-flow pumps, and a closed aortic valve are associated with AI. Large cohort studies would improve our understanding of this condition.

  5. Cost-Effectiveness of Ventricular Assist Device Destination Therapy for Advanced Heart Failure in Duchenne Muscular Dystrophy.

    Science.gov (United States)

    Magnetta, Defne A; Kang, JaHyun; Wearden, Peter D; Smith, Kenneth J; Feingold, Brian

    2018-05-17

    Destination ventricular assist device therapy (DT-VAD) is well accepted in select adults with medically refractory heart failure (HF) who are not transplant candidates; however, its use in younger patients with progressive diseases is unclear. We sought to evaluate the cost-effectiveness of DT-VAD in Duchenne muscular dystrophy (DMD) patients with advanced HF. We created a Markov-state transition model (5-year horizon) to compare survival, costs, and quality of life (QOL) between medical management and DT-VAD in DMD with advanced HF. Model input parameters were derived from the literature. We used sensitivity analyses to explore uncertainty around model assumptions. DT-VAD had higher costs ($435,602 vs. $125,696), survival (3.13 vs. 0.60 years), and quality-adjusted survival (1.99 vs. 0.26 years) than medical management. The incremental cost-effectiveness ratio (ICER) for DT-VAD was $179,086 per quality-adjusted life year (QALY). In sensitivity analyses that were widely varied to account for uncertainty in model assumptions, the DT-VAD strategy generally remained more costly and effective than medical management. Only when VAD implantation costs were <$113,142 did the DT-VAD strategy fall below the $100,000/QALY willingness-to-pay threshold commonly considered to be "cost-effective." In this exploratory analysis, DT-VAD for patients with DMD and advanced HF exceeded societal expectations for cost-effectiveness but had an ICER similar to the accepted practice of DT-VAD in adult HF patients. While more experience and research in this population is needed, our analysis suggests that DT-VAD for advanced HF in DMD should not be dismissed solely based on cost.

  6. Exercise physiology with a left ventricular assist device: Analysis of heart-pump interaction with a computational simulator.

    Science.gov (United States)

    Fresiello, Libera; Rademakers, Frank; Claus, Piet; Ferrari, Gianfranco; Di Molfetta, Arianna; Meyns, Bart

    2017-01-01

    Patients with a Ventricular Assist Device (VAD) are hemodynamically stable but show an impaired exercise capacity. Aim of this work is to identify and to describe the limiting factors of exercise physiology with a VAD. We searched for data concerning exercise in heart failure condition and after VAD implantation from the literature. Data were analyzed by using a cardiorespiratory simulator that worked as a collector of inputs coming from different papers. As a preliminary step the simulator was used to reproduce the evolution of hemodynamics from rest to peak exercise (ergometer cycling) in heart failure condition. Results evidence an increase of cardiac output of +2.8 l/min and a heart rate increase to 67% of the expected value. Then, we simulated the effect of a continuous-flow VAD at both rest and exercise. Total cardiac output increases of +3.0 l/min (+0.9 l/min due to the VAD and +2.1 l/min to the native ventricle). Since the left ventricle works in a non-linear portion of the diastolic stiffness line, we observed a consistent increase of pulmonary capillary wedge pressure (from 14 to 20 mmHg) for a relatively small increase of end-diastolic volume (from 182 to 189 cm3). We finally increased VAD speed during exercise to the maximum possible value and we observed a reduction of wedge pressure (-4.5 mmHg), a slight improvement of cardiac output (8.0 l/min) and a complete unloading of the native ventricle. The VAD can assure a proper hemodynamics at rest, but provides an insufficient unloading of the left ventricle and does not prevent wedge pressure from rising during exercise. Neither the VAD provides major benefits during exercise in terms of total cardiac output, which increases to a similar extend to an unassisted heart failure condition. VAD speed modulation can contribute to better unload the ventricle but the maximal flow reachable with the current devices is below the cardiac output observed in a healthy heart.

  7. Single axis controlled hybrid magnetic bearing for left ventricular assist device: hybrid core and closed magnetic circuit.

    Science.gov (United States)

    da Silva, Isaias; Horikawa, Oswaldo; Cardoso, Jose R; Camargo, Fernando A; Andrade, Aron J P; Bock, Eduardo G P

    2011-05-01

    In previous studies, we presented main strategies for suspending the rotor of a mixed-flow type (centrifugal and axial) ventricular assist device (VAD), originally presented by the Institute Dante Pazzanese of Cardiology (IDPC), Brazil. Magnetic suspension is achieved by the use of a magnetic bearing architecture in which the active control is executed in only one degree of freedom, in the axial direction of the rotor. Remaining degrees of freedom, excepting the rotation, are restricted only by the attraction force between pairs of permanent magnets. This study is part of a joint project in development by IDPC and Escola Politecnica of São Paulo University, Brazil. This article shows advances in that project, presenting two promising solutions for magnetic bearings. One solution uses hybrid cores as electromagnetic actuators, that is, cores that combine iron and permanent magnets. The other solution uses actuators, also of hybrid type, but with the magnetic circuit closed by an iron core. After preliminary analysis, a pump prototype has been developed for each solution and has been tested. For each prototype, a brushless DC motor has been developed as the rotor driver. Each solution was evaluated by in vitro experiments and guidelines are extracted for future improvements. Tests have shown good results and demonstrated that one solution is not isolated from the other. One complements the other for the development of a single-axis-controlled, hybrid-type magnetic bearing for a mixed-flow type VAD. © 2011, Copyright the Authors. Artificial Organs © 2011, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  8. Impact of ventricular assist device placement on longitudinal renal function in children with end-stage heart failure.

    Science.gov (United States)

    May, Lindsay J; Montez-Rath, Maria E; Yeh, Justin; Axelrod, David M; Chen, Sharon; Maeda, Katsuhide; Almond, Christopher S D; Rosenthal, David N; Hollander, Seth A; Sutherland, Scott M

    2016-04-01

    Although ventricular assist devices (VADs) restore hemodynamics in those with heart failure, reversibility of end-organ dysfunction with VAD support is not well characterized. Renal function often improves in adults after VAD placement, but this has not been comprehensively explored in children. Sixty-three children on VAD support were studied. Acute kidney injury (AKI) was defined by Kidney Disease: Improving Global Outcomes criteria. Estimated glomerular filtration rate (eGFR) was determined by the Schwartz method. Generalized linear mixed-effects models compared the pre-VAD and post-VAD eGFR for the cohort and sub-groups with and without pre-VAD renal dysfunction (pre-VAD eGFR renal dysfunction. AKI affected 60.3% (38 of 63), with similar rates in those with and without pre-existing renal dysfunction. Within the cohort, the nadir eGFR occurred 1 day post-operatively (62.9 ml/min/1.73 m(2); IQR, 51.2-88.9 ml/min/1.73 m(2); p renal dysfunction experienced the greatest improvement in the eGFR (β = 0.0051 vs β = 0.0013, p Renal dysfunction is prevalent in children with heart failure undergoing VAD placement. Although peri-operative AKI is common, renal function improves substantially in the first post-operative week and for months thereafter. This is particularly pronounced in those with pre-VAD renal impairment, suggesting that VADs may facilitate recovery and maintenance of kidney function in children with advanced heart failure. Copyright © 2016 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

  9. Pathology in patients with ventricular assist devices: a study of 21 autopsies, 24 ventricular apical core biopsies and 24 explanted hearts.

    Science.gov (United States)

    Rose, Alan G; Park, Soon J

    2005-01-01

    Ventricular assist devices (VADs) are used as a bridge to cardiac transplantation or as a permanent or sometimes temporary treatment for end stage heart failure. Our autopsy and surgical pathology experience with VADs prior to August 2002 was reviewed. Noted were patient's age, sex, underlying (UCOD) and proximate causes of death (PCOD), duration of VAD implantation, presence of native or prosthetic valvar disease and organ complications. Myocardium from biopsies and explanted hearts were blindly assessed for coagulative necrosis (CN), contraction bands (CB), myocytolysis (MC), increased eosinophilia (IE), myocyte waviness (MW) and fibrosis (F). Each was graded as either mild (score 1), moderate (score 2) or severe (score 3). Autopsy patients: Twenty-one patients, with mean age 55 years (range 10-73), comprised 10 women and 11 men. UCOD was ischemic disease in 16 patients, dilated cardiomyopathy in 4 and aortic valve disease in 1. The mean duration of VAD implantation was 125.7 days (range 1-1095 days, S.D.=253.6). Five patients had biventricular VADs, and 16 had LVAD only. Acquired aortic valve fusion was noted in three patients. PCOD was VAD related in six, donor heart problem in four, cerebrovascular accident in four, miscellaneous in three, pulmonary hypertension in two and aortic disease in two patients. Morbidity: local liver necrosis in seven, acquired aortic valve disease in four, gut infarction in three, abdominal aortic aneurysm in two and host cell assault against VAD porcine aortic valves in one case. Biopsies and explanted hearts: Twenty-four patients had a mean age of 53 years (range 38-68, S.D.=8.6). VADs were implanted for 177.8 days (range 7-593 days, S.D.=151.1). Comparison of histologic scores of biopsies with explanted hearts showed the following: CN 1.33 (S.D.=1.4)/0.21 (S.D.=0.66; P<.001); CB: 2.1 (S.D.=0.93)/0.83 (S.D.=0.28; NS); MC: 0.88 (S.D.=1.19)/0.13 (S.D.=0.34; P<.01); IE: 1.71 (S.D.=1.27)/0.38 (S.D.=0.65; NS); fibrosis: 1.08 (S.D.=1

  10. The Impact of Obesity on Patients Bridged to Transplantation With Continuous-Flow Left Ventricular Assist Devices.

    Science.gov (United States)

    Clerkin, Kevin J; Naka, Yoshifumi; Mancini, Donna M; Colombo, Paolo C; Topkara, Veli K

    2016-10-01

    This study sought to determine if obese patients had worse post-left ventricular assist device (LVAD) implantation outcomes and if the implantation of an LVAD allowed for weight loss. Obesity is a risk factor for cardiovascular disease including heart failure. Obese heart failure patients have better outcomes than those with normal weight; however, obese patients have worse outcomes after heart transplantation. Patients were identified in the United Network for Organ Sharing (UNOS) database that underwent LVAD implantation as bridge to transplantation from May 2004 and April 2014, with follow-up through June 2014. Patients were grouped according to body mass index (BMI) based on the World Health Organization classification. Among 3,856 patients, the risk of death or delisting was not significantly different between BMI groups (p = 0.347). There was no increased risk of death (p = 0.234) or delisting (p = 0.918). The risk of complication requiring UNOS status upgrade was increased for those with class II obesity or greater (hazard ratio: 1.48; p = 0.004), driven by increased infection and thromboembolism. Obese patients had worse post-transplantation outcomes. Weight loss substantial enough to decrease BMI group was achieved by a small proportion of patients listed with class I obesity or greater (9.6% to 15.5%). Patients with obesity had similar freedom from death or delisting while on LVAD support. However, class II obese or greater patients had an increased risk of complications requiring UNOS status upgrade compared with those with normal BMI during LVAD support and decreased post-transplantation survival. Weight loss on device therapy was possible, but uncommon. Careful consideration is needed when a bridge to weight loss strategy is proposed. Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  11. Ambient hemolysis and activation of coagulation is different between HeartMate II and HeartWare left ventricular assist devices.

    Science.gov (United States)

    Birschmann, Ingvild; Dittrich, Marcus; Eller, Thomas; Wiegmann, Bettina; Reininger, Armin J; Budde, Ulrich; Strüber, Martin

    2014-01-01

    Thromboembolic and bleeding events in patients with a left ventricular assist device (LVAD) are still a major cause of complications. Therefore, the balance between anti-coagulant and pro-coagulant factors needs to be tightly controlled. The principle hypothesis of this study is that different pump designs may have an effect on hemolysis and activation of the coagulation system. Referring to this, the HeartMate II (HMII; Thoratec Corp, Pleasanton, CA) and the HeartWare HVAD (HeartWare International Inc, Framingham, MA) were investigated. For 20 patients with LVAD support (n = 10 each), plasma coagulation, full blood count, and clinical chemistry parameters were measured. Platelet function was monitored using platelet aggregometry, platelet function analyzer-100 system ( Siemens, Marburg, Germany), vasodilator-stimulated phosphoprotein phosphorylation assay, immature platelet fraction, platelet-derived microparticles, and von Willebrand diagnostic. Acquired von Willebrand syndrome could be detected in all patients. Signs of hemolysis, as measured by lactate dehydrogenase levels (mean, 470 U/liter HMII, 250 U/liter HVAD; p < 0.001), were more pronounced in the HMII patients. In contrast, D-dimer analysis indicated a significantly higher activation of the coagulation system in HVAD patients (mean, 0.94 mg/liter HMII, 2.01 mg/liter HVAD; p < 0.01). The efficacy of anti-platelet therapy using clopidogrel was not sufficient in more than 50% of the patients. Our results support the finding that all patients with rotary blood pumps suffered from von Willebrand syndrome. In addition, a distinct footprint of effects on hemolysis and the coagulation system can be attributed to different devices. As a consequence, the individual status of the coagulation system needs to be controlled in long-term patients. © 2013 Published by International Society for the Heart and Lung Transplantation on behalf of International Society for Heart and Lung Transplantation.

  12. Multicentre clinical trial experience with the HeartMate 3 left ventricular assist device: 30-day outcomes.

    Science.gov (United States)

    Zimpfer, Daniel; Netuka, Ivan; Schmitto, Jan D; Pya, Yuriy; Garbade, Jens; Morshuis, Michiel; Beyersdorf, Friedhelm; Marasco, Silvana; Rao, Vivek; Damme, Laura; Sood, Poornima; Krabatsch, Thomas

    2016-09-01

    The objective of this study was to describe the operative experience and 30-day outcomes of patients implanted with the HeartMate 3 Left Ventricular Assist System (LVAS) during the Conformité Européenne (CE) Mark clinical trial. Adult patients met inclusion and exclusion criteria defining advanced-stage heart failure and included the indications of bridge to transplant and destination therapy. Operative parameters, outcomes, adverse events, physical status and quality-of-life parameters were assessed in the first 30 days after LVAS implant. Fifty patients were implanted with the HeartMate 3 at 10 centres in 6 countries. The 30-day survival rate was 98%. The median operative and cardiopulmonary bypass times were 200 (range: 95-585) min and 84 (range: 47-250) min, respectively. Patients required transfusion with packed red blood cells (3.6 ± 2.3 units), fresh frozen plasma (6.5 ± 5 units) and platelets (2 ± 1 units). Six patients (12%) required reoperation for postoperative bleeding and 10 patients (20%) did not require blood transfusion. The median intensive care time was 6 days (range: 1-112 days) and the total hospital stay was 28 days (range: 14-116 days). The most common adverse events were bleeding (15, 30%), arrhythmia (14, 28%) and infection (10, 20%). There were 2 (4%) strokes. The 30-day outcomes following implantation of the HeartMate 3 demonstrates excellent survival with low adverse event rates. The LVAD performed as intended with no haemolysis or device failure. NCT02170363. HeartMate 3™ CE Mark Clinical Investigation Plan (HM3 CE Mark). © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  13. Decision making for destination therapy left ventricular assist devices: "there was no choice" versus "I thought about it an awful lot".

    Science.gov (United States)

    McIlvennan, Colleen K; Allen, Larry A; Nowels, Carolyn; Brieke, Andreas; Cleveland, Joseph C; Matlock, Daniel D

    2014-05-01

    Destination therapy left ventricular assist devices (DT LVADs) are one of the most invasive medical interventions for end-stage illness. How patients decide whether or not to proceed with device implantation is unknown. We aimed to understand the decision-making processes of patients who either accept or decline DT LVADs. Between October 2012 and September 2013, we conducted semistructured, in-depth interviews to understand patients' decision-making experiences. Data were analyzed using a mixed inductive and deductive approach. Twenty-two eligible patients were interviewed, 15 with DT LVADs and 7 who declined. We found a strong dichotomy between decision processes with some patients (11 accepters) being automatic and others (3 accepters, 7 decliners) being reflective in their approach to decision making. The automatic group was characterized by a fear of dying and an over-riding desire to live as long as possible: "[LVAD] was the only option I had…that or push up daisies…so I automatically took this." By contrast, the reflective group went through a reasoned process of weighing risks, benefits, and burdens: "There are worse things than death." Irrespective of approach, most patients experienced the DT LVAD decision as a highly emotional process and many sought support from their families or spiritually. Some patients offered a DT LVAD face the decision by reflecting on a process and reasoning through risks and benefits. For others, the desire to live supersedes such reflective processing. Acknowledging this difference is important when considering how to support patients who are faced with this complex decision. © 2014 American Heart Association, Inc.

  14. Simulation of dilated heart failure with continuous flow circulatory support.

    Directory of Open Access Journals (Sweden)

    Yajuan Wang

    Full Text Available Lumped parameter models have been employed for decades to simulate important hemodynamic couplings between a left ventricular assist device (LVAD and the native circulation. However, these studies seldom consider the pathological descending limb of the Frank-Starling response of the overloaded ventricle. This study introduces a dilated heart failure model featuring a unimodal end systolic pressure-volume relationship (ESPVR to address this critical shortcoming. The resulting hemodynamic response to mechanical circulatory support are illustrated through numerical simulations of a rotodynamic, continuous flow ventricular assist device (cfVAD coupled to systemic and pulmonary circulations with baroreflex control. The model further incorporated septal interaction to capture the influence of left ventricular (LV unloading on right ventricular function. Four heart failure conditions were simulated (LV and bi-ventricular failure with/without pulmonary hypertension in addition to normal baseline. Several metrics of LV function, including cardiac output and stroke work, exhibited a unimodal response whereby initial unloading improved function, and further unloading depleted preload reserve thereby reducing ventricular output. The concept of extremal loading was introduced to reflect the loading condition in which the intrinsic LV stroke work is maximized. Simulation of bi-ventricular failure with pulmonary hypertension revealed inadequacy of LV support alone. These simulations motivate the implementation of an extremum tracking feedback controller to potentially optimize ventricular recovery.

  15. The Myosuit: Bi-articular Anti-gravity Exosuit That Reduces Hip Extensor Activity in Sitting Transfers.

    Science.gov (United States)

    Schmidt, Kai; Duarte, Jaime E; Grimmer, Martin; Sancho-Puchades, Alejandro; Wei, Haiqi; Easthope, Chris S; Riener, Robert

    2017-01-01

    Muscle weakness-which can result from neurological injuries, genetic disorders, or typical aging-can affect a person's mobility and quality of life. For many people with muscle weakness, assistive devices provide the means to regain mobility and independence. These devices range from well-established technology, such as wheelchairs, to newer technologies, such as exoskeletons and exosuits. For assistive devices to be used in everyday life, they must provide assistance across activities of daily living (ADLs) in an unobtrusive manner. This article introduces the Myosuit, a soft, wearable device designed to provide continuous assistance at the hip and knee joint when working with and against gravity in ADLs. This robotic device combines active and passive elements with a closed-loop force controller designed to behave like an external muscle (exomuscle) and deliver gravity compensation to the user. At 4.1 kg (4.6 kg with batteries), the Myosuit is one of the lightest untethered devices capable of delivering gravity support to the user's knee and hip joints. This article presents the design and control principles of the Myosuit. It describes the textile interface, tendon actuators, and a bi-articular, synergy-based approach for continuous assistance. The assistive controller, based on bi-articular force assistance, was tested with a single subject who performed sitting transfers, one of the most gravity-intensive ADLs. The results show that the control concept can successfully identify changes in the posture and assist hip and knee extension with up to 26% of the natural knee moment and up to 35% of the knee power. We conclude that the Myosuit's novel approach to assistance using a bi-articular architecture, in combination with the posture-based force controller, can effectively assist its users in gravity-intensive ADLs, such as sitting transfers.

  16. The Myosuit: Bi-articular Anti-gravity Exosuit That Reduces Hip Extensor Activity in Sitting Transfers

    Directory of Open Access Journals (Sweden)

    Kai Schmidt

    2017-10-01

    Full Text Available Muscle weakness—which can result from neurological injuries, genetic disorders, or typical aging—can affect a person's mobility and quality of life. For many people with muscle weakness, assistive devices provide the means to regain mobility and independence. These devices range from well-established technology, such as wheelchairs, to newer technologies, such as exoskeletons and exosuits. For assistive devices to be used in everyday life, they must provide assistance across activities of daily living (ADLs in an unobtrusive manner. This article introduces the Myosuit, a soft, wearable device designed to provide continuous assistance at the hip and knee joint when working with and against gravity in ADLs. This robotic device combines active and passive elements with a closed-loop force controller designed to behave like an external muscle (exomuscle and deliver gravity compensation to the user. At 4.1 kg (4.6 kg with batteries, the Myosuit is one of the lightest untethered devices capable of delivering gravity support to the user's knee and hip joints. This article presents the design and control principles of the Myosuit. It describes the textile interface, tendon actuators, and a bi-articular, synergy-based approach for continuous assistance. The assistive controller, based on bi-articular force assistance, was tested with a single subject who performed sitting transfers, one of the most gravity-intensive ADLs. The results show that the control concept can successfully identify changes in the posture and assist hip and knee extension with up to 26% of the natural knee moment and up to 35% of the knee power. We conclude that the Myosuit's novel approach to assistance using a bi-articular architecture, in combination with the posture-based force controller, can effectively assist its users in gravity-intensive ADLs, such as sitting transfers.

  17. Outcomes of pediatric patients supported with continuous-flow ventricular assist devices: A report from the Pediatric Interagency Registry for Mechanical Circulatory Support (PediMACS).

    Science.gov (United States)

    Rossano, Joseph W; Lorts, Angela; VanderPluym, Christina J; Jeewa, Aamir; Guleserian, Kristine J; Bleiweis, Mark S; Reinhartz, Olaf; Blume, Elizabeth D; Rosenthal, David N; Naftel, David C; Cantor, Ryan S; Kirklin, James K

    2016-05-01

    Continuous-flow (CF) ventricular assist devices (VADs) have largely replaced pulsatile-flow VADs in adult patients. However, there are few data on CF VADs among pediatric patients. In this study we aimed to describe the overall use, patients' characteristics and outcomes of CF VADs in this population. The Pediatric Interagency Registry for Mechanical Circulatory Support (PediMACS) is a national registry for U.S. Food and Drug Adminstration (FDA)-approved VADs in patients <19 years of age. Patients undergoing placement of durable CF VADs between September 2012 and June 2015 were included and outcomes were compared with those of adults from the Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS). CF VADs were implanted in 109 patients at 35 hospitals. The median age at implantation was 15 years (2.8 to 18.9 years) and median weight was 62 kg (range 16 to 141 kg). The underlying disease was cardiomyopathy in 89 (82%) patients. The INTERMACS level at time of implant was Level 1 in 20 (19%), Level 2 in 64 (61%) and Levels 3 to 7 in 21 (20%) patients. Most were implanted as LVADs (n = 102, 94%). Median duration of support was 2.3 months (range <1 day to 28 months). Serious adverse event rates were low, including neurologic dysfunction (early event rate 4.1 per 100 patient-months with 2 late events). Competing outcomes analysis at 6 months post-implant indicated 61% transplanted, 31% alive with device in place and 8% death before transplant. These outcomes compared favorably with the 3,894 adults supported with CF VADs as a bridge to transplant. CF VADs are commonly utilized in older children and adolescents, with excellent survival rates. Further study is needed to understand impact of patient and device characteristics on outcomes in pediatric patients. Copyright © 2016 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

  18. Fluid force predictions and experimental measurements for a magnetically levitated pediatric ventricular assist device.

    Science.gov (United States)

    Throckmorton, Amy L; Untaroiu, Alexandrina; Lim, D Scott; Wood, Houston G; Allaire, Paul E

    2007-05-01

    The latest generation of artificial blood pumps incorporates the use of magnetic bearings to levitate the rotating component of the pump, the impeller. A magnetic suspension prevents the rotating impeller from contacting the internal surfaces of the pump and reduces regions of stagnant and high shear flow that surround fluid or mechanical bearings. Applying this third-generation technology, the Virginia Artificial Heart Institute has developed a ventricular assist device (VAD) to support infants and children. In consideration of the suspension design, the axial and radial fluid forces exerted on the rotor of the pediatric VAD were estimated using computational fluid dynamics (CFD) such that fluid perturbations would be counterbalanced. In addition, a prototype was built for experimental measurements of the axial fluid forces and estimations of the radial fluid forces during operation using a blood analog mixture. The axial fluid forces for a centered impeller position were found to range from 0.5 +/- 0.01 to 1 +/- 0.02 N in magnitude for 0.5 +/- 0.095 to 3.5 +/- 0.164 Lpm over rotational speeds of 6110 +/- 0.39 to 8030 +/- 0.57% rpm. The CFD predictions for the axial forces deviated from the experimental data by approximately 8.5% with a maximum difference of 18% at higher flow rates. Similarly for the off-centered impeller conditions, the maximum radial fluid force along the y-axis was found to be -0.57 +/- 0.17 N. The maximum cross-coupling force in the x direction was found to be larger with a maximum value of 0.74 +/- 0.22 N. This resulted in a 25-35% overestimate of the radial fluid force as compared to the CFD predictions; this overestimation will lead to a far more robust magnetic suspension design. The axial and radial forces estimated from the computational results are well within a range over which a compact magnetic suspension can compensate for flow perturbations. This study also serves as an effective and novel design methodology for blood pump

  19. Comparative analysis of von Willebrand factor profiles after implantation of left ventricular assist device and total artificial heart.

    Science.gov (United States)

    Reich, H J; Morgan, J; Arabia, F; Czer, L; Moriguchi, J; Ramzy, D; Esmailian, F; Lam, L; Dunhill, J; Volod, O

    2017-08-01

    Essentials Bleeding is a major source of morbidity during mechanical circulatory support. von Willebrand factor (VWF) multimer loss may contribute to bleeding. Different patterns of VWF multimer loss were seen with the two device types. This is the first report of total artificial heart associated VWF multimer loss. Background Bleeding remains a challenge during mechanical circulatory support and underlying mechanisms are incompletely understood. Functional von Willebrand factor (VWF) impairment because of loss of high-molecular-weight multimers (MWMs) produces acquired von Willebrand disease (VWD) after left ventricular assist device (LVAD). Little is known about VWF multimers with total artificial hearts (TAHs). Here, VWF profiles with LVADs and TAHs are compared using a VWD panel. Methods VWD evaluations for patients with LVAD or TAH (2013-14) were retrospectively analyzed and included: VWF activity (ristocetin cofactor, VWF:RCo), VWF antigen (VWF:Ag), ratio of VWF:RCo to VWF:Ag, and quantitative VWF multimeric analysis. Results Twelve patients with LVADs and 12 with TAHs underwent VWD evaluation. All had either normal (47.8%) or elevated (52.2%) VWF:RCo, normal (26.1%) or elevated (73.9%) VWF:Ag and 50.0% were disproportional (ratio ≤ 0.7). Multimeric analysis showed abnormal patterns in all patients with LVADs: seven with high MWM loss; five with highest MWM loss. With TAH, 10/12 patients had abnormal patterns: all with highest MWM loss. High MWM loss correlated with presence of LVAD and highest MWM loss with TAH. Increased low MWMs were detected in 22/24. Conclusion Using VWF multimeric analysis, abnormalities after LVAD or TAH were detected that would be missed with measurements of VWF level alone: loss of high MWM predominantly in LVAD, loss of highest MWM in TAH, and elevated levels of low MWM in both. This is the first study to describe TAH-associated highest MWM loss, which may contribute to bleeding. © 2017 International Society on Thrombosis and

  20. 76 FR 36548 - Circulatory System Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting

    Science.gov (United States)

    2011-06-22

    ... information related to the humanitarian device exemption for the Berlin Heart EXCOR Pediatric Ventricular Assist Device (VAD) sponsored by Berlin Heart, Inc. The Berlin Heart EXCOR Pediatric VAD device is a..., please contact AnnMarie Williams, Conference Management Staff, at 301-796-5966, at least 7 days in...

  1. Flow visualization of a monoleaflet and bileaflet mechanical heart valve in a pneumatic ventricular assist device using a PIV system.

    Science.gov (United States)

    Lee, Hwansung; Tatsumi, Eisuke; Taenaka, Yoshiyuki

    2010-01-01

    Our group is developing a new type of pulsatile pneumatic ventricular assist device (PVAD) that uses the Medtronic Hall tilting disc valve (M-H valve). Although tilting disc valves have good washout effect inside the blood pump, they are no longer in common clinical use and may be difficult to obtain in the future. To investigate the stability of the Sorin Bicarbon valve (S-B valve) in our PVAD, we constructed a model pump made of an acrylic resin with the same configuration as our PVAD and attempted to compare the flow visualization upstream and downstream of the outlet position valve between the M-H valve and the S-B valve using a particle image velocimetry (PIV) method. The outlet S-B valve had faster closure than the M-H valve. The maximum flow velocity was greater than with the M-H valve. The maximum Reynolds shear stress (RSS) of the M-H valve reached 150 N/m(2) and that of the S-B valve reached 300 N/m(2) upstream during the end-systolic and early-diastolic phases. In both valves, the maximum RSS upstream of the valve was higher than downstream of the valve because of the regurgitation flow during valve closure. In addition, the maximum viscous shear stress reached above 2 N/m(2), which occupied only about 1%-1.5% of the maximum RSS.

  2. Quality of life and functional capacity outcomes in the MOMENTUM 3 trial at 6 months: A call for new metrics for left ventricular assist device patients.

    Science.gov (United States)

    Cowger, Jennifer A; Naka, Yoshifumi; Aaronson, Keith D; Horstmanshof, Douglas; Gulati, Sanjeev; Rinde-Hoffman, Debbie; Pinney, Sean; Adatya, Sirtaz; Farrar, David J; Jorde, Ulrich P

    2018-01-01

    The Multicenter Study of MAGLEV Technology in Patients Undergoing Mechanical Circulatory Support Therapy with HeartMate 3 (MOMENTUM 3) clinical trial demonstrated improved 6-month event-free survival, but a detailed analysis of health-related quality of life (HR-QOL) and functional capacity (FC) was not presented. Further, the effect of early serious adverse events (SAEs) on these metrics and on the general ability to live well while supported with a left ventricular assist system (LVAS) warrants evaluation. FC (New York Heart Association [NYHA] and 6-minute walk test [6MWT]) and HR-QOL (European Quality of Life [EQ-5D-5L] and the Kansas City Cardiomyopathy [KCCQ]) assessments were obtained at baseline and 6 months after HeartMate 3 (HM3, n = 151; Abbott, Abbott Park, IL) or HeartMate II (HMII, n = 138; Abbott) implant as part of the MOMENTUM 3 clinical trial. Metrics were compared between devices and in those with and without events. The proportion of patients "living well on an LVAS" at 6 months, defined as alive with satisfactory FC (NYHA I/II or 6MWT > 300 meters) and HR-QOL (overall KCCQ > 50), was evaluated. Although the median (25th-75th percentile) patient KCCQ (change for HM3: +28 [10-46]; HMII: +29 [9-48]) and EQ-5D-5L (change for HM3: -1 [-5 to 0]; HMII: -2 [-6 to 0]) scores improved from baseline to 6 months (p 0.05). Likewise, there was an equivalent improvement in 6MWT distance at 6 months in HM3 (+94 [1-274] meters] and HMII (+188[43-340 meters]) from baseline. In patients with SAEs (n = 188), 6MWTs increased from baseline (p < 0.001), but gains for both devices were less than those without SAE (HM3: +74 [-9 to 183] meters with SAE vs +140 [35-329] meters without SAE; HMII: +177 [47-356] meters with SAE vs +192 [23-337] meters without SAE, both p < 0.003). SAEs did not affect the 6-month HR-QOL scores. The "living well" end point was achieved in 145 HM3 (63%) and 120 HMII (68%) patients (p = 0.44). Gains in HR-QOL and FC were similar early after HM3

  3. Assistive Devices

    Science.gov (United States)

    If you have a disability or injury, you may use a number of assistive devices. These are tools, products or types of equipment that help you perform tasks and activities. They may help you move around, see, communicate, eat, or get ...

  4. Impact of pacing on systemic ventricular function in L-transposition of the great arteries.

    Science.gov (United States)

    Hofferberth, Sophie C; Alexander, Mark E; Mah, Douglas Y; Bautista-Hernandez, Victor; del Nido, Pedro J; Fynn-Thompson, Francis

    2016-01-01

    To assess the impact of univentricular versus biventricular pacing (BiVP) on systemic ventricular function in patients with congenitally corrected transposition of the great arteries (ccTGA). We performed a retrospective review of all patients with a diagnosis of ccTGA who underwent pacemaker insertion. From 1993 to 2014, 53 patients were identified from the cardiology database and surgical records. Overall mortality was 7.5% (n = 4). One patient required transplantation and 3 late deaths occurred secondary to end-stage heart failure. Median follow-up was 3.7 years (range, 4 days to 22.5 years). Twenty-five (47%) underwent univentricular pacing only, of these, 8 (32%) developed significant systemic ventricular dysfunction. Twenty-eight (53%) received BiVP, 17 (26%) were upgraded from a dual-chamber system, 11 (21%) received primary BiVP. Fourteen (82%) of the 17 undergoing secondary BiVP demonstrated systemic ventricular dysfunction at the time of pacer upgrade, with 7 (50%) demonstrating improved systemic ventricular function after pacemaker upgrade. Overall, 42 (79%) patients underwent univentricular pacing, with 22 (52%) developing significant systemic ventricular dysfunction. In contrast, the 11 (21%) who received primary BiVP had preserved systemic ventricular function at latest follow-up. Late-onset systemic ventricular dysfunction is a major complication associated with the use of univentricular pacing in patients with ccTGA. All patients with ccTGA who develop heart block should undergo primary biventricular pacing, as this prevents late systemic ventricular dysfunction. Preemptive placement of BiVP leads at the time of anatomical repair or other permanent palliative procedure will facilitate subsequent BiVP should heart block develop. Copyright © 2016 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  5. BiFeO3 epitaxial thin films and devices: past, present and future

    Science.gov (United States)

    Sando, D.; Barthélémy, A.; Bibes, M.

    2014-11-01

    The celebrated renaissance of the multiferroics family over the past ten years has also been that of its most paradigmatic member, bismuth ferrite (BiFeO3). Known since the 1960s to be a high temperature antiferromagnet and since the 1970s to be ferroelectric, BiFeO3 only had its bulk ferroic properties clarified in the mid-2000s. It is however the fabrication of BiFeO3 thin films and their integration into epitaxial oxide heterostructures that have fully revealed its extraordinarily broad palette of functionalities. Here we review the first decade of research on BiFeO3 films, restricting ourselves to epitaxial structures. We discuss how thickness and epitaxial strain influence not only the unit cell parameters, but also the crystal structure, illustrated for instance by the discovery of the so-called T-like phase of BiFeO3. We then present its ferroelectric and piezoelectric properties and their evolution near morphotropic phase boundaries. Magnetic properties and their modification by thickness and strain effects, as well as optical parameters, are covered. Finally, we highlight various types of devices based on BiFeO3 in electronics, spintronics, and optics, and provide perspectives for the development of further multifunctional devices for information technology and energy harvesting.

  6. Study of photocatalytic activities of Bi{sub 2}WO{sub 6} nanoparticles synthesized by fast microwave-assisted method

    Energy Technology Data Exchange (ETDEWEB)

    Phu, Nguyen Dang [Faculty of Physics, Hanoi National University of Education, 136 Xuanthuy, Cau Giay, Hanoi (Viet Nam); Hoang, Luc Huy, E-mail: hoanglhsp@hnue.edu.vn [Faculty of Physics, Hanoi National University of Education, 136 Xuanthuy, Cau Giay, Hanoi (Viet Nam); Chen, Xiang-Bai, E-mail: xchen@wit.edu.cn [School of Science and Laboratory of Optical Information Technology, Wuhan Institute of Technology, Wuhan 430205 (China); Kong, Meng-Hong [School of Science and Laboratory of Optical Information Technology, Wuhan Institute of Technology, Wuhan 430205 (China); Wen, Hua-Chiang; Chou, Wu Ching [Department of Electrophysics, National Chiao Tung University, Hsin-Chu 30010, Taiwan (China)

    2015-10-25

    We present a study of photocatalytic activities of Bi{sub 2}WO{sub 6} nanoparticles synthesized by fast microwave-assisted method. The photocatalytic activities of the nanoparticles were evaluated by the decolorization of methylene-blue under visible-light-irradiation. Our results show that the surface area of Bi{sub 2}WO{sub 6} nanoparticles plays a major role for improving photocatalytic activity, while visible-light absorption has only a weak effect on photocatalytic activity. This suggests efficient transportation of photo-generated electrons and holes to the oxidation active sites on the surface of nanoparticles, indicating Bi{sub 2}WO{sub 6} nanoparticles synthesized by fast microwave-assisted method are promising for achieving high photocatalytic activity under visible-light-irradiation. - Highlights: • The Bi{sub 2}WO{sub 6} nanoparticles were synthesized via fast microwave-assisted method. • The obtained Bi{sub 2}WO{sub 6} nanoparticles exhibited visible-light absorbance. • The surface area of Bi{sub 2}WO{sub 6} nanoparticles plays major role for improving photocatalytic activity. • The Bi{sub 2}WO{sub 6} nanoparticles are promising for achieving high photocatalytic activity under visible-light-irradiation.

  7. Novel Left Ventricular Assist Systems® I and II for Cardiac Recovery: The Driver

    OpenAIRE

    Cervino, Claudio; Nasini, Victor; Sroka, Agnieszka; Diluch, Armando; Cáceres, Miguel; Sellanes, Miguel; Malusardi, Adriano; del Rio, Miguel; Pham, Si M.; Liotta, Domingo

    2005-01-01

    We have recently described the Novel Left Ventricular Assist Systems® (Novel LVAS®) I and II, which avoid cannulation of cardiac chambers and synchronize pumping with the patient's electrocardiogram.

  8. Screening for heart transplantation and left ventricular assist system

    DEFF Research Database (Denmark)

    Lund, Lars H; Trochu, Jean-Noel; Meyns, Bart

    2018-01-01

    BACKGROUND: Heart transplantation (HTx) and implantable left ventricular assist systems (LVAS) improve outcomes in advanced heart failure but may be underutilized. We hypothesized that screening can identify appropriate candidates. METHODS AND RESULTS: The ScrEEning for advanced Heart Failure...... treatment (SEE-HF) study was a multicentre prospective study screening patients with existing cardiac resynchronization therapy (CRT) and/or implantable cardioverter-defibrillator (ICD) for ejection fraction ≤40% and New York Heart Association (NYHA) class III-IV, and subsequently for guideline-based HTx...

  9. Design of wheel-type walking-assist device

    International Nuclear Information System (INIS)

    Jung, Seung Ho; Kim, Seung Ho; Kim, Chang Hoi; Seo, Yong Chil; Jung, Kyung Min; Lee, Sung Uk

    2006-03-01

    In this research, a outdoor wheel-type walking-assist device is developed to help an elder having a poor muscular strength at legs for walking, sitting and standing up easily at outdoors, and also for going and downing stairs. In conceptually designing, the environments of an elder's activity, the size of an elder's body and a necessary function of helping an elder are considered. This device has 4 wheels for stability. When an elder walks in incline plane with the proposed device, a rear-wing is rotated to keep the supporting device horizontal, regardless of an angle of inclination. A height-controlling device, which can control the height of the supporting device for adjusting an elder's height, is varied vertically to help an elder to sit and stand-up easily. Moreover, a outdoor wheel-type walking-assist device is conceptually designed and is made. In order to design it, the preview research is investigated firstly. On the basis of the proposed walking-assist device, the outdoor walking-assist device is designed and made. The outdoor wheel-type walking-assist device can go and down stairs automatically. This device go up and down the stair of having maximum 20cm height and an angle of 25 degrees with maximum 4 sec/stairs speed, and move at flatland with 60cm/sec speed

  10. Social Support Moderates the Relationship Between Perceived Stress and Quality of Life in Patients With a Left Ventricular Assist Device.

    Science.gov (United States)

    Abshire, Martha; Russell, Stuart D; Davidson, Patricia M; Budhathoki, Chakra; Han, Hae-Ra; Grady, Kathleen L; Desai, Shashank; Dennison Himmelfarb, Cheryl

    2018-04-20

    Living with a left ventricular assist device has significant psychosocial sequelae that affect health-related quality of life (HRQOL). The purpose of this study was to (1) describe psychosocial indicators of stress including perceived stress, depression, fatigue, and coping; (2) examine relationships among stress indicators by level of perceived stress; (3) examine relationships among indicators of stress and clinical outcomes; and (4) test the moderation of social support on the relationship between stress and clinical outcomes. Participants were recruited from 2 outpatient clinics in a cross-sectional study design. Standardized measures were self-administered via survey. Descriptive statistics, correlation, and multiple linear regression analysis were conducted. The sample (N = 62) was mostly male (78%), black (47%), and married (66%), with a mean age of 56.5 ± 13 years. The overall sample had a moderate stress profile: moderate perceived stress (mean, 11.7 ± 7), few depressive symptoms (mean, 3.2 ± 3.9), and moderate fatigue (mean, 14.3 ± 9.1). Increased perceived stress was associated with fatigue, depressive symptoms, and maladaptive coping (P stress and fatigue were significant correlates of overall HRQOL (adj. R = 0.41, P relationship between perceived stress and HRQOL, controlling for fatigue (R = 0.49, P stress have worse depressive symptoms, fatigue, and coping. The influence of high social support to improve the relationship between stress and HRQOL underscores the importance of a comprehensive plan to address psychosocial factors.

  11. Improved Approach With Subcostal Exchange of the HeartMate II Left Ventricular Assist Device: Difference in On and Off Pump?

    Science.gov (United States)

    Gaffey, Ann C; Chen, Carol W; Chung, Jennifer J; Phillips, Emily; Wald, Joyce; Williams, Matthew L; Low, David W; Acker, Michael A; Atluri, Pavan

    2017-11-01

    The HeartMate II (St. Jude Medical, Inc, St. Paul, MN [previously Thoratec]) left ventricular assist device (LVAD) exchange has traditionally involved a redo sternotomy. Alternate minimally invasive subcostal approaches have the advantage of avoiding sternal reentry, excessive bleeding, and prolonged recovery. This retrospective review included patients who underwent an exchange from May 2009 to March 2016. The patients were divided into three cohorts: (1) redo sternotomy, (2) subcostal approach involving cardiopulmonary bypass (CPB) (ON-CPB SC), and (3) subcostal approach off the CPB pump (OFF-CPB SC). Data pertaining to patients' baseline characteristics and outcomes were collected and analyzed. From May 1, 2009 to July 31, 2016, 33 HeartMate II LVAD exchanges were performed. There were 11 redo sternotomies and 22 subcostal exchanges, 12 of which were in the OFF-CPB SC group. There was no significant difference among the groups in terms of age (p = 0.75), sex (p = 0.95), and indication for exchange (p = 0.94). There was a higher red blood cell transfusion requirement within the sternotomy cohort (p rates were equivalent among the cohorts. Exchange of the HeartMate II LVAD can be accomplished with significantly improved recovery time and transfusion requirement through a less invasive subcostal approach when compared with sternotomy. The subcostal approach can be performed safely both on and off cardiopulmonary bypass. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  12. Brain-controlled body movement assistance devices and methods

    Energy Technology Data Exchange (ETDEWEB)

    Leuthardt, Eric C.; Love, Lonnie J.; Coker, Rob; Moran, Daniel W.

    2017-01-10

    Methods, devices, systems, and apparatus, including computer programs encoded on a computer storage medium, for brain-controlled body movement assistance devices. In one aspect, a device includes a brain-controlled body movement assistance device with a brain-computer interface (BCI) component adapted to be mounted to a user, a body movement assistance component operably connected to the BCI component and adapted to be worn by the user, and a feedback mechanism provided in connection with at least one of the BCI component and the body movement assistance component, the feedback mechanism being configured to output information relating to a usage session of the brain-controlled body movement assistance device.

  13. Magnetic properties in MnBi alloy of small crystallites for permanent magnet devices

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, S. K.; Prakash, H. R.; Ram, S., E-mail: jms.sanjeev@gmail.com [Materials Science Centre, Indian Institute of Technology, Kharagpur-721302 (India)

    2016-05-06

    A rare-earth free alloy like MnBi is a potential candidate for developing small magnets and devices. In a commercially viable method, a MnBi alloy was prepared by arc melting Mn and Bi metals in a 1:1 ratio. In terms of the X-ray diffraction a single crystalline MnBi phase is formed of the as prepared alloy. FESEM images delineate thin MnBi layers (25 – 40 nm thickness) of average EDX composition throughout the specimen. A large coercivity 5.501 kOe (6.5 emu/g magnetization) observed in an M-H at 300 K is decreased to 0.171 (9.0 emu/g magnetization) at 100 K in decreasing upon cooling.

  14. Microwave-assisted hydrothermal synthesis of Bi2S3 nanorods in flower-shaped bundles

    International Nuclear Information System (INIS)

    Thongtem, Titipun; Pilapong, Chalermchai; Kavinchan, Jutarat; Phuruangrat, Anukorn; Thongtem, Somchai

    2010-01-01

    Bi 2 S 3 nanorods in flower-shaped bundles were successfully synthesized from the decomposition of Bi-thiourea complexes under the microwave-assisted hydrothermal process. X-ray powder diffraction (XRD) patterns and field emission scanning electron microscopy (FE-SEM) show that Bi 2 S 3 has the orthorhombic phase and appears as nanorods in flower-shaped bundles. A transmission electron microscopic (TEM) study reveals the independent single Bi 2 S 3 nanorods with their growth along the [0 0 1] direction. A possible formation mechanism of Bi 2 S 3 nanorods in flower-shaped bundles is also proposed and discussed. Their UV-vis spectrum shows the absorbance at 596 nm, with its direct energy band gap of 1.82 eV.

  15. Facile Br- assisted hydrothermal synthesis of Bi2MoO6 nanoplates with enhanced visible-light photocatalytic activity

    International Nuclear Information System (INIS)

    Zhang, Peng; Teng, Xiaoxu; Liu, Dongsheng; Fu, Liang; Xie, Hualin; Zhang, Guoqing; Ding, Shimin

    2017-01-01

    Bi 2 MoO 6 nanoplates have been controllably synthesized via a facile hydrothermal process with the assistance of Br - containing surfactant cetyltrimethylammonium bromide (CTAB) or KBr. A remarkable enhancement in the visible-light-driven photocatalytic degradation of Rhodamine B was observed. It was found that reaction temperature and surfactant play crucial roles in the formation and properties of the Bi 2 MoO 6 nanoplates. The best results as photocatalyst were obtained with the sample hydrothermally synthesized at 150 C with the assistance of CTAB. The improved photocatalytic performance could be ascribed to the {001}-oriented nanostructure of the Bi 2 MoO 6 nanoplates. KBr-templated Bi 2 MoO 6 nanoplates also showed better photocatalytic efficiency compared with that of flower-like Bi 2 MoO 6 but inferior to that of CTAB-templated Bi 2 MoO 6 nanoplates. (orig.)

  16. Wearable Assistive Devices for the Blind

    OpenAIRE

    Velazquez, Ramiro

    2016-01-01

    Assistive devices are a key aspect in wearable systems for biomedical applications, as they represent potential aids for people with physical and sensory disabilities that might lead to improvements in the quality of life. This chapter focuses on wearable assistive devices for the blind. It intends to review the most significant work done in this area, to present the latest approaches for assisting this population and to understand universal design concepts for the development of wearable ass...

  17. Transesophageal Echocardiography-Guided Epicardial Left Ventricular Lead Placement by Video-Assisted Thoracoscopic Surgery in Nonresponders to Biventricular Pacing and Previous Chest Surgery.

    Science.gov (United States)

    Schroeder, Carsten; Chung, Jane M; Mackall, Judith A; Cakulev, Ivan T; Patel, Aaron; Patel, Sunny J; Hoit, Brian D; Sahadevan, Jayakumar

    2018-06-14

    The aim of the study was to study the feasibility, safety, and efficacy of transesophageal echocardiography-guided intraoperative left ventricular lead placement via a video-assisted thoracoscopic surgery approach in patients with failed conventional biventricular pacing. Twelve patients who could not have the left ventricular lead placed conventionally underwent epicardial left ventricular lead placement by video-assisted thoracoscopic surgery. Eight patients had previous chest surgery (66%). Operative positioning was a modified far lateral supine exposure with 30-degree bed tilt, allowing for groin and sternal access. To determine the optimal left ventricular location for lead placement, the left ventricular surface was divided arbitrarily into nine segments. These segments were transpericardially paced using a hand-held malleable pacing probe identifying the optimal site verified by transesophageal echocardiography. The pacing leads were screwed into position via a limited pericardiotomy. The video-assisted thoracoscopic surgery approach was successful in all patients. Biventricular pacing was achieved in all patients and all reported symptomatic benefit with reduction in New York Heart Association class from III to I-II (P = 0.016). Baseline ejection fraction was 23 ± 3%; within 1-year follow-up, the ejection fraction increased to 32 ± 10% (P = 0.05). The mean follow-up was 566 days. The median length of hospital stay was 7 days with chest tube removal between postoperative days 2 and 5. In patients who are nonresponders to conventional biventricular pacing, intraoperative left ventricular lead placement using anatomical and functional characteristics via a video-assisted thoracoscopic surgery approach is effective in improving heart failure symptoms. This optimized left ventricular lead placement is feasible and safe. Previous chest surgery is no longer an exclusion criterion for a video-assisted thoracoscopic surgery approach.

  18. The Role of Implantable Cardioverter Defibrillators in Patients Bridged to Transplantation with a Continuous Flow Left Ventricular Assist Device: A Propensity Score Matched Analysis

    Science.gov (United States)

    Clerkin, Kevin J.; Topkara, Veli K.; Mancini, Donna M.; Yuzefpolskaya, Melana; Demmer, Ryan T.; Dizon, Jose M.; Takeda, Koji; Takayama, Hiroo; Naka, Yoshifumi; Colombo, Paolo C.; Garan, A. Reshad

    2016-01-01

    Background Implantable cardioverter defibrillators (ICD) provide a significant mortality benefit for appropriately selected patients with advanced heart failure. ICDs are associated with a mortality benefit when used in patients with a pulsatile left ventricular assist device (LVAD). However it is unclear whether patients with a continuous flow LVAD (CF-LVAD) derive the same benefit. This study sought to determine if the presence of an ICD provided a mortality benefit during CFLVAD support as a bridge to transplantation. Methods Patients were identified in the United Network for Organ Sharing (UNOS) registry that underwent LVAD implantation as bridge to transplantation from May 2004 and April 2014, with follow-up through June 2014. The primary outcome was freedom from death while on CF-LVAD support with adjustment for complications requiring UNOS listing status upgrade. Secondary endpoints included freedom from delisting while on CF-LVAD support and incidence of transplantation. Results 2,990 patients composed the study cohort and propensity score matching identified 1,012 patients with similar propensity scores. There was no difference in survival during device support between patients with and without an ICD (Hazard Ratio [HR] 1.20, 95% Confidence Interval [CI] 0.66-2.17, p=0.55). Adjusting for device complications requiring a UNOS listing status upgrade had minimal influence (HR 1.11, 95% CI 0.60-2.05, p=0.74). There was no increased risk of delisting due to being too sick for those with an ICD (HR 1.08, 95% CI 0.63-1.86, p=0.78). Likewise, the probability of transplantation was similar (HR 1.05, 95% CI 0.87-1.27, p=0.62). Conclusions Among patients bridged to transplantation with a CF-LVAD, the presence of an ICD did not reduce mortality. PMID:28089072

  19. The role of implantable cardioverter defibrillators in patients bridged to transplantation with a continuous-flow left ventricular assist device: A propensity score matched analysis.

    Science.gov (United States)

    Clerkin, Kevin J; Topkara, Veli K; Mancini, Donna M; Yuzefpolskaya, Melana; Demmer, Ryan T; Dizon, Jose M; Takeda, Koji; Takayama, Hiroo; Naka, Yoshifumi; Colombo, Paolo C; Garan, A Reshad

    2017-06-01

    Implantable cardioverter defibrillators (ICDs) provide a significant mortality benefit for appropriately selected patients with advanced heart failure. ICDs are associated with a mortality benefit when used in patients with a pulsatile left ventricular assist device (LVAD). It is unclear whether patients with a continuous-flow LVAD (CF-LVAD) derive the same benefit. We sought to determine if the presence of an ICD provided a mortality benefit during CF-LVAD support as a bridge to transplantation. Patients were identified in the United Network for Organ Sharing (UNOS) registry who underwent LVAD implantation as bridge to transplantation between May 2004 and April 2014, with follow-up through June 2014. Primary outcome was freedom from death while on CF-LVAD support with adjustment for complications requiring UNOS listing status upgrade. Secondary end-points included freedom from delisting while on CF-LVAD support and incidence of transplantation. The study cohort comprised 2,990 patients, and propensity score matching identified 1,012 patients with similar propensity scores. There was no difference in survival during device support between patients with and without an ICD (hazard ratio [HR] = 1.20; 95% confidence interval [CI], 0.66-2.17; p = 0.55). Adjusting for device complications requiring a UNOS listing status upgrade had minimal influence (HR = 1.11; 95% CI, 0.60-2.05; p = 0.74). There was no increased risk of delisting owing to being too sick for patients with an ICD (HR = 1.08; 95% CI, 0.63-1.86; p = 0.78). Likewise, the probability of transplantation was similar (HR = 1.05; 95% CI, 0.87-1.27; p = 0.62). Among patients bridged to transplantation with a CF-LVAD, the presence of an ICD did not reduce mortality. Copyright © 2017 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

  20. Innovative Free-range Resonant Electrical Energy Delivery system (FREE-D System) for a ventricular assist device using wireless power.

    Science.gov (United States)

    Waters, Benjamin H; Smith, Joshua R; Bonde, Pramod

    2014-01-01

    Technological innovation of a smaller, single moving part has an advantage over earlier large pulsatile ventricular assist devices (VADs) prone to mechanical failure. Drivelines limit the potential for extended patient survival durations with newer pumps and act as source for infection, increased morbidity, rehospitalizations, and reduced quality of life. The Free-range Resonant Electrical Energy Delivery (FREE-D) wireless power system uses magnetically coupled resonators to efficiently transfer power. We demonstrate the efficiency over distance of this system. The experimental setup consists of an radiofrequency amplifier and control board which drives the transmit resonator coil, and a receiver unit consisting of a resonant coil attached to a radiofrequency rectifier and power management module. The power management module supplies power to the axial pump, which was set at 9,600 rpm. To achieve a seamless wireless delivery in any room size, we introduced a third relay coil. This relay coil can be installed throughout a room, whereas a single relay coil could be built into a jacket worn by the patient, which would always be within range of the receive coil implanted in the patient's body. The power was delivered over a meter distance without interruptions or fluctuations with coil, rectifier, and regulator efficiency more than 80% and overall system efficiency of 61%. The axial pump worked well throughout the 8 hours of continuous operation. Having same setup on the opposite side can double the distance. A tether-free operation of a VAD can be achieved by FREE-D system in room-size distances. It has the potential to make the VAD therapy more acceptable from the patient perspective.

  1. Usefulness of Tricuspid Annular Diameter to Predict Late Right Sided Heart Failure in Patients With Left Ventricular Assist Device.

    Science.gov (United States)

    Nakanishi, Koki; Homma, Shunichi; Han, Jiho; Takayama, Hiroo; Colombo, Paolo C; Yuzefpolskaya, Melana; Garan, Arthur R; Farr, Maryjane A; Kurlansky, Paul; Di Tullio, Marco R; Naka, Yoshifumi; Takeda, Koji

    2018-07-01

    Although late-onset right-sided heart failure is recognized as a clinical problem in the treatment of patients with left ventricular assist devices (LVADs), the mechanism and predictors are unknown. Tricuspid valve (TV) deformation leads to the restriction of the leaflet motion and decreased coaptation, resulting in a functional tricuspid regurgitation that may act as a surrogate marker of late right-sided heart failure. This study aimed to investigate the association of preoperative TV deformation (annulus dilatation and leaflet tethering) with late right-sided heart failure development after continuous-flow LVAD implantation. The study cohort consisted of 274 patients who underwent 2-dimensional echocardiography before LVAD implantation. TV annulus diameter and tethering distance were measured in an apical 4-chamber view. Late right-sided heart failure was defined as right-sided heart failure requiring readmission and medical and/or surgical treatment after initial LVAD implantation. During a mean follow-up of 25.1 ± 19.0 months after LVAD implantation, late right-sided heart failure occurred in 33 patients (12.0%). Multivariate Cox proportional hazard analysis demonstrated that TV annulus diameter (hazard ratio 1.221 per 1 mm, p right-sided heart failure development, whereas leaflet tethering distance was not. The best cut-off value of the TV annular diameter was 41 mm (area under the curve 0.787). Kaplan-Meier analysis showed that patients with dilated TV annulus (TV annular diameter ≥41 mm) exhibited a significantly higher late right-sided heart failure occurrence than those without TV annular enlargement (log-rank p right-sided heart failure after LVAD implantation. Copyright © 2018 Elsevier Inc. All rights reserved.

  2. Local electric field screening in bi-layer graphene devices

    Directory of Open Access Journals (Sweden)

    Vishal ePanchal

    2014-02-01

    Full Text Available We present experimental studies of both local and macroscopic electrical effects in uniform single- (1LG and bi-layer graphene (2LG devices as well as in devices with non-uniform graphene coverage, under ambient conditions. DC transport measurements on sub-micron scale Hall bar devices were used to show a linear rise in carrier density with increasing amounts of 2LG coverage. Electrical scanning gate microscopy was used to locally top gate uniform and non-uniform devices in order to observe the effect of local electrical gating. We experimentally show a significant level of electric field screening by 2LG. We demonstrate that SGM technique is an extremely useful research tool for studies of local screening effects, which provides a complementary view on phenomena that are usually considered only within a macroscopic experimental scheme.

  3. Predictors of survival and ability to wean from short-term mechanical circulatory support device following acute myocardial infarction complicated by cardiogenic shock.

    Science.gov (United States)

    Garan, A Reshad; Eckhardt, Christina; Takeda, Koji; Topkara, Veli K; Clerkin, Kevin; Fried, Justin; Masoumi, Amirali; Demmer, Ryan T; Trinh, Pauline; Yuzefpolskaya, Melana; Naka, Yoshifumi; Burkhoff, Dan; Kirtane, Ajay; Colombo, Paolo C; Takayama, Hiroo

    2017-11-01

    Cardiogenic shock following acute myocardial infarction (AMI-CS) portends a poor prognosis. Short-term mechanical circulatory support devices (MCSDs) provide hemodynamic support for patients with cardiogenic shock but predictors of survival and the ability to wean from short-term MCSDs remain largely unknown. All patients > 18 years old treated at our institution with extra-corporeal membrane oxygenation or short-term surgical ventricular assist device for AMI-CS were studied. We collected acute myocardial infarction details with demographic and hemodynamic variables. Primary outcomes were survival to discharge and recovery from MCSD (i.e. survival without heart replacement therapy including durable ventricular assist device or heart transplant). One hundred and twenty-four patients received extra-corporeal membrane oxygenation or short-term surgical ventricular assist device following acute myocardial infarction from 2007 to 2016; 89 received extra-corporeal membrane oxygenation and 35 short-term ventricular assist device. Fifty-five (44.4%) died in the hospital and 69 (55.6%) survived to discharge. Twenty-six (37.7%) required heart replacement therapy (four transplant, 22 durable ventricular assist device) and 43 (62.3%) were discharged without heart replacement therapy. Age and cardiac index at MCSD implantation were predictors of survival to discharge; patients over 60 years with cardiac index <1.5 l/min per m 2 had a low likelihood of survival. The angiographic result after revascularization predicted recovery from MCSD (odds ratio 9.00, 95% confidence interval 2.45-32.99, p=0.001), but 50% of those optimally revascularized still required heart replacement therapy. Cardiac index predicted recovery from MCSD among this group (odds ratio 4.06, 95% confidence interval 1.45-11.55, p=0.009). Among AMI-CS patients requiring short-term MCSDs, age and cardiac index predict survival to discharge. Angiographic result and cardiac index predict ventricular recovery but 50

  4. Josephson effect in Al/Bi{sub 2}Se{sub 3}/Al coplanar hybrid devices

    Energy Technology Data Exchange (ETDEWEB)

    Galletti, L., E-mail: luca.galletti@unina.it [Dipartimento di Scienze Fisiche, Università degli Studi di Napoli Federico II, I-80126 Napoli (Italy); CNR-SPIN Napoli, Complesso Universitario di Monte Sant’Angelo, 80126 Napoli (Italy); Charpentier, S. [Department of Microtechnology and Nanoscience, Chalmers University of Technology, SE-41296 Göteborg (Sweden); Lucignano, P.; Massarotti, D. [Dipartimento di Scienze Fisiche, Università degli Studi di Napoli Federico II, I-80126 Napoli (Italy); CNR-SPIN Napoli, Complesso Universitario di Monte Sant’Angelo, 80126 Napoli (Italy); Arpaia, R. [Dipartimento di Scienze Fisiche, Università degli Studi di Napoli Federico II, I-80126 Napoli (Italy); Department of Microtechnology and Nanoscience, Chalmers University of Technology, SE-41296 Göteborg (Sweden); Tafuri, F. [CNR-SPIN Napoli, Complesso Universitario di Monte Sant’Angelo, 80126 Napoli (Italy); Dipartimento di Ingegneria Industriale e dell’Informazione, Seconda Università di Napoli, I-81031 Aversa (CE) (Italy); Bauch, T. [Department of Microtechnology and Nanoscience, Chalmers University of Technology, SE-41296 Göteborg (Sweden); Suzuki, Y. [University of Tsukuba, Institute of Materials Science, Tsukuba 305, Ibaraki (Japan); Tagliacozzo, A. [Dipartimento di Scienze Fisiche, Università degli Studi di Napoli Federico II, I-80126 Napoli (Italy); Kadowaki, K. [University of Tsukuba, Institute of Materials Science, Tsukuba 305, Ibaraki (Japan); Lombardi, F. [Department of Microtechnology and Nanoscience, Chalmers University of Technology, SE-41296 Göteborg (Sweden)

    2014-08-15

    Highlights: • Superconducting proximity effect induced in Al/Bi{sub 2}Se{sub 3}/Al coplanar hybrid devices. • Comparative study of Al/Bi{sub 2}Se{sub 3} interfaces with various buffer layers. • Towards a Josephson super-current through the edge states of topological insulators. - Abstract: The edge states of Topological Insulators (TI) are protected against backscattering, thanks to the topological properties arising from their band structure. Coupling a TI to a superconductor (S) can induce unconventional effects, including the creation of Majorana bound states (MBS). The fabrication of coplanar hybrid devices is a fundamental step to pave the way to the understanding of proximity effects in topologically non-trivial systems, and to a large variety of experiments aimed at the possible detection of MBS. We discuss the feasibility and some relevant properties of Al–Bi{sub 2}Se{sub 3}–Al coplanar proximity devices. Special attention is devoted to the design of the junction, aimed at enhancing the coupling between the electrodes and the TI.

  5. Is anti-platelet therapy needed in continuous flow left ventricular assist device patients? A single-centre experience.

    Science.gov (United States)

    Litzler, Pierre-Yves; Smail, Hassiba; Barbay, Virginie; Nafeh-Bizet, Catherine; Bouchart, François; Baste, Jean-Marc; Abriou, Caroline; Bessou, Jean-Paul

    2014-01-01

    We report our 5-year experience of continuous flow left ventricular assist device (LVAD) implantation without the use of anti-platelet therapy. Between February 2006 and September 2011, 27 patients (26 men; 1 woman) were implanted with a continuous flow LVAD (HeartMate II, Thoratec Corporation, Pleasanton, CA, USA). The mean age was 55.7 ± 9.9 years. The mean duration of support was 479 ± 436 (1-1555) days with 35.4 patient-years on support. Twenty-one patients were implanted as a bridge to transplantation and 6 for destination therapy. The anticoagulation regimen was fluindione for all patients, with aspirin for only 4 patients. At the beginning of our experience, aspirin was administered to 4 patients for 6, 15, 60 and 460 days. Due to gastrointestinal (GI) bleeding and epistaxis, aspirin was discontinued, and since August 2006, no patients have received anti-platelet therapy. At 3 years, the survival rate during support was 76%. The most common postoperative adverse event was GI bleeding (19%) and epistaxis (30%) (median time: 26 days) for patients receiving fluindione and aspirin. The mean International Normalized Ratio (INR) was 2.58 ± 0.74 during support. Fifteen patients have been tested for acquired Von Willebrand disease. A diminished ratio of collagen-binding capacity and ristocetin cofactor activity to Von Willebrand factor antigen was observed in 7 patients. In the postoperative period, 2 patients presented with ischaemic stroke at 1 and 8 months. One of these 2 patients had a previous history of carotid stenosis with ischaemic stroke. There were no patients with haemorrhagic stroke, transient ischaemic attack or pump thrombosis. The event rate of stroke (ischaemic and haemorrhagic) per patient-year was 0.059 among the patients without aspirin with fluindione regimen only. A fluindione regimen without aspirin in long-duration LVAD support appears to not increase thromboembolic events and could lead to a diminished risk of haemorrhagic stroke.

  6. Decision Making for Destination Therapy Left Ventricular Assist Devices: “There was no choice” versus “I thought about it an awful lot”

    Science.gov (United States)

    McIlvennan, Colleen K.; Allen, Larry A.; Nowels, Carolyn; Brieke, Andreas; Cleveland, Joseph C.; Matlock, Daniel D.

    2014-01-01

    Background Destination therapy left ventricular assist devices (DT LVAD) are one of the most invasive medical interventions for end-stage illness. How patients decide whether or not to proceed with device implantation is unknown. We aimed to understand the decision-making processes of patients who either accept or decline DT LVADs. Methods and Results Between October 2012–September 2013, we conducted semi-structured, in-depth interviews to understand patients’ decision-making experiences. Data were analyzed using a mixed inductive and deductive approach. Twenty-two eligible patients were interviewed, 15 with DT LVADs and 7 who declined. We found a strong dichotomy between decision processes with some patients (11 accepters) being “automatic” and others (3 accepters, 7 decliners) being “reflective” in their approach to decision making. The automatic group was characterized by a fear of dying and an overriding desire to live as long as possible: “[LVAD] was the only option I had…that or push up daisies…so I automatically took this”. In contrast, the reflective group went through a reasoned process of weighing risks, benefits, and burdens: “There are worse things than death.” Irrespective of approach, most patients experienced the DT LVAD decision as a highly emotional process and many sought support from their families or spiritually. Conclusion Some patients offered a DT LVAD face the decision by reflecting on a process and reasoning through risks and benefits. For others, the desire to live supersedes such reflective processing. Acknowledging this difference is important when considering how to support patients who are faced with this complex decision. PMID:24823949

  7. Dynamics of device innovation: implications for assessing value.

    Science.gov (United States)

    Gelijns, Annetine C; Russo, Mark J; Hong, Kimberly N; Brown, Lawrence D; Ascheim, Deborah D; Moskowitz, Alan J

    2013-10-01

    In recent years, there has been growing interest in evaluating the health and economic impact of medical devices. Payers increasingly rely on cost-effectiveness analyses in making their coverage decisions, and are adopting value-based purchasing initiatives. These analytic approaches, however, have been shaped heavily by their use in the pharmaceutical realm, and are ill-adapted to the medical device context. This study focuses on the development and evaluation of left ventricular assist devices (LVADs) to highlight the unique challenges involved in the design and conduct of device trials compared with pharmaceuticals. Devices are moving targets characterized by a much higher degree of post-introduction innovation and "learning by using" than pharmaceuticals. The cost effectiveness ratio of left ventricular assist devices for destination therapy, for example, decreased from around $600,000 per life year saved based on results from the pivotal trial to around $100,000 within a relatively short time period. These dynamics pose fundamental challenges to the evaluation enterprise as well as the policy-making world, which this paper addresses.

  8. Anesthetic management of Amplatzer atrial septal defect closure device embolization to right ventricular outflow tract

    Directory of Open Access Journals (Sweden)

    S Das

    2016-01-01

    Full Text Available Percutaneous device closure of atrial septal defect (ASD is an alternative treatment to surgery with advantages of avoidance of surgery, short procedure time, early discharge from hospital, and lower rates of complications. However, percutaneous device closure is associated with infrequent life-threatening complications such as device embolization. We report a case device embolization of the ASD occlude device into right ventricular outflow tract resulting progressive hypoxia. The role of anesthesiologist as a team leader in managing such emergency is discussed.

  9. Hemodynamic Effects of Ventricular Assist Device Implantation on Norwood, Glenn, and Fontan Circulation: A Simulation Study.

    Science.gov (United States)

    Di Molfetta, Arianna; Amodeo, Antonio; Gagliardi, Maria G; Trivella, Maria G; Fresiello, Libera; Filippelli, Sergio; Toscano, Alessandra; Ferrari, Gianfranco

    2016-01-01

    The growing population of failing single-ventricle (SV) patients might benefit from ventricular assist device (VAD) support as a bridge to heart transplantation. However, the documented experience is limited to isolated case reports. Considering the complex and different physiopathology of Norwood, Glenn, and Fontan patients and the lack of established experience, the aim of this work is to realize and test a lumped parameter model of the cardiovascular system able to simulate SV hemodynamics and VAD implantation effects to support clinical decision. Hemodynamic and echocardiographic data of 30 SV patients (10 Norwood, 10 Glenn, and 10 Fontan) were retrospectively collected and used to simulate patients' baseline. Then, the effects of VAD implantation were simulated. Simulation results suggest that the implantation of VAD: (i) increases the cardiac output and the mean arterial systemic pressure in all the three palliation conditions (Norwood 77.2 and 19.7%, Glenn 38.6 and 32.2%, and Fontan 17.2 and 14.2%); (ii) decreases the SV external work (Norwood 55%, Glenn 35.6%, and Fontan 41%); (iii) decreases the pressure pulsatility index (Norwood 65.2%, Glenn 81.3%, and Fontan 64.8%); (iv) increases the pulmonary arterial pressure in particular in the Norwood circulation (Norwood 39.7%, Glenn 12.1% and Fontan 3%); and (v) decreases the atrial pressure (Norwood 2%, Glenn 10.6%, and Fontan 8.6%). Finally, the VAD work is lower in the Norwood circulation (30.4 mL·mm Hg) in comparison with Fontan (40.3 mL·mm Hg) and to Glenn (64.5 mL·mm Hg) circulations. The use of VAD in SV physiology could be helpful to bridge patients to heart transplantations by increasing the CO and unloading the SV with a decrement of the atrial pressure and the SV external work. The regulation of the pulmonary flow is challenging because the Pap is increased by the presence of VAD. The hemodynamic changes are different in the different SV palliation step. The use of numerical models

  10. Management of single-ventricle patients with Berlin Heart EXCOR Ventricular Assist Device: single-center experience.

    Science.gov (United States)

    Mackling, Tracey; Shah, Tejas; Dimas, Vivian; Guleserian, Kristine; Sharma, Mahesh; Forbess, Joseph; Ardura, Monica; Gross-Toalson, Jami; Lee, Ying; Journeycake, Janna; Barnes, Aliessa

    2012-06-01

    There are minimal data regarding chronic management of single-ventricle ventricular assist device (VAD) patients. This study aims to describe our center's multidisciplinary team management of single-ventricle patients supported long term with the Berlin Heart EXCOR Pediatric VAD. Patient #1 was a 4-year-old with double-outlet right ventricle with aortic atresia, L-looped ventricles, and heart block who developed heart failure 1 year after Fontan. She initially required extracorporeal membrane oxygenation support and was transitioned to Berlin Heart systemic VAD. She was supported for 363 days (cardiac intensive care unit [CICU] 335 days, floor 28 days). The postoperative course was complicated by intermittent infection including methicillin-resistant Staphylococcus aureus, intermittent hepatic and renal insufficiencies, and transient antithrombin, protein C, and protein S deficiencies resulting in multiple thrombi. She had a total of five pump changes over 10 months. Long-term medical management included anticoagulation with enoxaparin, platelet inhibition with aspirin and dipyridamole, and antibiotic prophylaxis using trimethoprim/sulfamethoxazole. She developed sepsis of unknown etiology and subsequently died from multiorgan failure. Patient #2 was a 4-year-old with hypoplastic left heart syndrome who developed heart failure 2 years after bidirectional Glenn shunt. At systemic VAD implantation, he was intubated with renal insufficiency. Post-VAD implantation, his renal insufficiency resolved, and he was successfully extubated to daytime nasal cannula and biphasic positive airway pressure at night. He was supported for 270 days (CICU 143 days, floor 127 days). The pump was upsized to a 50-mL pump in May 2011 for increased central venous pressures (29 mm Hg). Long-term medical management included anticoagulation with warfarin and single-agent platelet inhibition using dipyridamole due to aspirin resistance. He developed increased work of breathing requiring

  11. Short-term mechanical circulatory support as a bridge to durable left ventricular assist device implantation in refractory cardiogenic shock: a systematic review and meta-analysis.

    Science.gov (United States)

    den Uil, Corstiaan A; Akin, Sakir; Jewbali, Lucia S; Dos Reis Miranda, Dinis; Brugts, Jasper J; Constantinescu, Alina A; Kappetein, Arie Pieter; Caliskan, Kadir

    2017-07-01

    Short-term mechanical circulatory support (MCS) is increasingly used as a bridge to decision in patients with refractory cardiogenic shock. Subsequently, these patients might be bridged to durable MCS either as a bridge to candidacy/transplantation, or as destination therapy. The aim of this study was to review support duration and clinical outcome of short-term MCS in cardiogenic shock, and to analyse application of this technology as a bridge to long-term cardiac support (left ventricular assist device, LVAD) from 2006 till June 2016. Using Cochrane Register of Trials, Embase and Medline, a systematic review was performed on patients with cardiogenic shock from acute myocardial infarction, end-stage cardiomyopathy, or acute myocarditis, receiving short-term MCS. Studies on periprocedural, post-cardiotomy and cardiopulmonary resuscitation support were excluded. Thirty-nine studies, mainly registries of heterogeneous patient populations (n = 4151 patients), were identified. Depending on the device used (intra-aortic balloon pump, TandemHeart, Impella 2.5, Impella 5.0, CentriMag and peripheral veno-arterial extracorporeal membrane oxygenation), mean support duration was (range) 1.6-25 days and the mean proportion of short-term MCS patients discharged was (range) 45-66%. The mean proportion of bridge to durable LVAD was (range) 3-30%. Bridge to durable LVAD was most frequently performed in patients with end-stage cardiomyopathy (22 [12-35]%). We conclude that temporary MCS can be used to bridge patients with cardiogenic shock towards durable LVAD. Clinicians are encouraged to share their results in a large multicentre registry in order to investigate optimal device selection and best duration of support. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  12. Preoperative Right-Sided Cardiac Congestion Is Associated with Gastrointestinal Bleeding in Patients with Continuous-Flow Left Ventricular Assist Devices.

    Science.gov (United States)

    Tomizawa, Yutaka; Tanaka, Akiko; Kitahara, Hiroto; Sakuraba, Atsushi; Uriel, Nir; Jeevanandam, Valluvan; Ota, Takeyoshi

    2018-06-01

    Large scale data on preoperative risk stratification for gastrointestinal bleeding (GIB) following continuous-flow left ventricular assist device (CF-LVAD) implantation are scarce. To identify independent predictors for GIB following CF-LVAD implantation. We conducted a retrospective cohort study of consecutive 243 patients who underwent CF-LVAD implantation (HeartMateII) from January 2009 to March 2015 at the University of Chicago Medical Center. GIB was defined as the presence of overt bleeding or occult GIB with ≥ 2 g/dl drop in hemoglobin (Hgb) from recorded baseline values and hemoccult-positive stool. The preoperative and postoperative data were reviewed. Within a median follow-up duration of 408 (IQR 113-954) days, 83 (34%) patients developed GIB after a median of 149 (IQR 27-615) days after implantation of CF-LVAD. There were no significant differences between the groups of GIB and non-GIB with respect to preoperative demographics and comorbidity except for ethnicity. The source of bleeding was identified in 39 (47%) patients and arteriovenous malformation or submucosal streaming vessel was the most frequent cause of bleeding (18/39, 46%). Multivariate-adjusted analysis demonstrated preoperative central venous pressure (CVP) ≥ 18 mmHg (HR 3.56; 95% CI 1.16-10.9; p = 0.026), mean pulmonary artery pressure (mPA) ≥ 36 mmHg (HR 4.14; 95% CI 1.35-12.7; p = 0.013), and the presence of moderate/severe tricuspid valve disease (HR 1.01; 95% CI 1.01-3.86; p = 0.046) were associated with the risk of GIB. In this study, preoperative right-sided cardiac congestion (i.e., increased CVP, mPA and the presence of moderate/severe tricuspid valve disease) was associated with GIB in patients with CF-LVAD.

  13. Interdependence of right ventricular systolic function and left ventricular filling and its association with outcome for patients with pulmonary hypertension.

    Science.gov (United States)

    Motoji, Yoshiki; Tanaka, Hidekazu; Fukuda, Yuko; Sano, Hiroyuki; Ryo, Keiko; Imanishi, Junichi; Miyoshi, Tatsuya; Sawa, Takuma; Mochizuki, Yasuhide; Matsumoto, Kensuke; Emoto, Noriaki; Hirata, Ken-ichi

    2015-04-01

    Although impaired right ventricular (RV) performance has been associated with adverse outcomes for pulmonary hypertension (PH) patients, the relationship between bi-ventricular interdependence and outcomes is not yet fully understood. We studied 96 PH patients. RV systolic function was assessed by means of RV free-wall longitudinal speckle-tracking strain (RV-free), and left ventricular (LV) filling as early diastolic transmitral flow velocity (TMF-E). RV-free ≤19 % and TMF-E functional class IV and brain natriuretic peptide >150 pg/dl (χ(2) = 1.2) was improved by the addition of RV-free (χ(2) = 5.5, p = 0.04) as well as of TMF-E (χ(2) = 11.5, p = 0.01). In conclusions, RV systolic function was shown to correlate significantly with LV filling in PH patients. In addition, not only assessment of RV systolic function, but also of a combined bi-ventricular parameter comprising RV systolic function and LV filling may well have clinical implications for more successful management of PH patients.

  14. Assistive Devices for Students with Disabilities.

    Science.gov (United States)

    Wisniewski, Lech; Sedlak, Robert

    1992-01-01

    Describes a variety of devices that can assist students with disabilities. Highlights recently developed devices for students with specific learning disabilities, and with vision, hearing, health, physical, and speech and language impairments. The devices can help rehabilitate, reeducate, facilitate normalcy, or augment current functioning. (GLR)

  15. Comparison of early versus delayed timing of left ventricular assist device implantation as a bridge-to-transplantation: An analysis of the UNOS dataset.

    Science.gov (United States)

    Kitada, Shuichi; Schulze, P Christian; Jin, Zhezhen; Clerkin, Kevin; Homma, Shunichi; Mancini, Donna M

    2016-01-15

    Placement of left ventricular assist devices (LVAD) as a bridge-to-heart transplantation (HTx) has rapidly expanded due to organ donor shortage. However, the timing of LVAD implantation is variable and it remains unclear if earlier implantation improves survival. We analyzed 14,187 adult candidates from the United Network of Organ Sharing database. Patients were classified by 3 treatment strategies including patients medically treated alone (MED, n=11,009), patients on LVAD support at listing (Early-LVAD, n=1588) and patients undergoing LVAD placement while awaiting HTx (Delayed-LVAD, n=1590). Likelihood of HTx and event-free survival were assessed in patients subcategorized by clinical strategies and UNOS status at listing. The device support strategy, despite the timing of placement, was not associated with increased likelihood of HTx compared to MED group. However, both LVAD implantation strategies showed better survival compared to MED group (Early-LVAD: HR 0.811 and 0.633, 95% CI 0.668-0.984 and 0.507-0.789, for 1A and 1B; p=0.034 and p<0.001, Delayed-LVAD: HR 0.553 and 0.696, 95% CI 0.415-0.736 and 0.571-0.847, for 1A and 1B; both p<0.001, respectively). Furthermore, there was no significant difference in survival between these LVAD implantation strategies in patients listed as 1B (p=0.500), although Early-LVAD implantation showed worse survival in patients listed as 1A (HR 1.467, 95% CI 1.076-2.000; p=0.015). LVAD support strategies offer a safe bridge-to-HTx. Those candidates who receive urgent upfront LVAD implantation for HTx, and improve to 1B status, would achieve competitive survival with those who receive elective LVAD implantation. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  16. Avaliação de um dispositivo portátil para biópsia vácuo-assistida de microcalcificações mamárias Evaluation of a portable device for vacuum-assisted biopsy of breast microcalcifications

    Directory of Open Access Journals (Sweden)

    Hélio Sebastião Amâncio de Camargo Júnior

    2010-04-01

    Full Text Available OBJETIVO: A biópsia vácuo-assistida é a forma percutânea de biópsia de microcalcificações que obtém a menor taxa de subestimação, porém, seu custo é alto, havendo interesse em se conseguir formas mais baratas de biópsia vácuo-assistida. O objetivo deste trabalho foi testar um dispositivo portátil de biópsia vácuo-assistida que apresenta custo menor. MATERIAIS E MÉTODOS: Foram biopsiadas 35 pacientes que apresentavam agrupamentos de microcalcificações BI-RADS® 4 ou 5. Foram testados a representatividade dos fragmentos colhidos, as dificuldades na reintrodução da cânula e o número de ciclos de colheita. RESULTADOS: Houve obtenção de calcificações representativas em todas as pacientes. Não houve discordância anatomorradiológica, dificuldade na reintrodução da cânula ou complicações graves. CONCLUSÃO: Os dados permitem concluir que o sistema apresenta boa eficácia na obtenção das amostras e com relação de custo-benefício favorável em relação a outros sistemas para a biópsia de microcalcificações, achados em concordância com outras publicações da literatura.OBJECTIVE: Vacuum-assisted biopsy is the percutaneous technique of breast biopsy with the lowest underestimation rate. However, the cost of such procedure is high and currently there is a considerable interest in developing less expensive techniques. The present study was aimed at testing a less expensive device for vacuum-assisted biopsy of breast microcalcifications. MATERIALS AND METHODS: Thirty-five patients with clustered microcalcifications classified as BI-RADS® 4 or 5 were submitted to biopsy. Collected specimen appropriateness, difficulties in the reinsertion of the cannula and number of biopsy passes were evaluated. RESULTS: Successful specimens collection was achieved in all of the patients. Histo-radiological disagreement, difficulties in the cannula reinsertion or severe complications were not observed. CONCLUSION: The authors

  17. Introduction of assistive devices: home nurses' practices and beliefs.

    Science.gov (United States)

    Roelands, Marc; Van Oost, Paulette; Depoorter, Anne Marie; Buysse, Ann; Stevens, Veerle

    2006-04-01

    This paper reports a study describing home nurses' intention and current practices regarding introducing assistive devices, and investigating whether their practice is related to social cognitive factors (attitudes, subjective norms and self-efficacy). Home nurses not only care for patients in particular medical domains, but also educate and guide them towards more independence. Patients with age-related disabilities in mobility and self-care might benefit from the use of assistive devices. A home nurse might be the first and only person to discuss the disability and use of an assistive device. Therefore, home nurses' beliefs about the introduction of assistive devices could affect their daily practices. A cross-sectional study was conducted with a convenience sample of 64 home nurses chosen from a random sample of home nursing departments. The home nurses completed a self-administered questionnaire. The Theory of Planned Behaviour framework was used to develop the social cognitive measures regarding each of the six steps distinguished in the introduction of assistive devices. Home nurses had positive attitudes and high levels of intention, subjective norm and self-efficacy towards most steps of the decision process to introduce assistive devices. In a multiple linear regression analysis, attitude and self-efficacy predicted intention to introduce assistive devices to older clients with disabilities. Intention was correlated to home nurses' current practices. The findings suggest that conditions are present to involve home nurses more explicitly in the introduction of assistive devices to their patients. Social cognitive factors should be taken into account when developing interventions that aim to support home nurses to do this.

  18. Role of ventricular assist therapy for patients with heart failure and restrictive physiology: Improving outcomes for a lethal disease.

    Science.gov (United States)

    Grupper, Avishay; Park, Soon J; Pereira, Naveen L; Schettle, Sarah D; Gerber, Yariv; Topilsky, Yan; Edwards, Brooks S; Daly, Richard C; Stulak, John M; Joyce, Lyle D; Kushwaha, Sudhir S

    2015-08-01

    Restrictive cardiomyopathy (RCM) patients have poor prognosis due to progressive heart failure characterized by impaired ventricular filling of either or both ventricles. The goal of this study was to evaluate the outcome of end-stage RCM patients after left ventricular assist device (LVAD) implantation and to determine factors that may be associated with improved survival. This investigation is a retrospective study of prospectively collected data that include 28 consecutive patients with end-stage RCM who received continuous-flow LVADs at the Mayo Clinic, Rochester, Minnesota. Outcome was assessed by survival with LVAD support until heart transplantation or all-cause mortality. The mean follow-up time post-LVAD implantation was 448 ± 425 days. The mean hospitalization time was 29 ± 19 days and was complicated mainly by post-operative right ventricular (RV) failure requiring short-term medical support. The short-term in-hospital mortality was 14%. Ten patients underwent heart transplantation with 100% survival post-transplant during the follow-up period. One-year survival for patients with LVADs without transplantation was 64%, and was not significantly different between amyloidosis and non-amyloidosis patients. Larger left ventricle (LV) end-diastolic and end-systolic dimensions were significantly associated with improved survival rates (RR = 0.94 and 0.95, p < 0.05, respectively), and left ventricular end-diastolic diameter (LVEDD) ≤46 mm was associated with increased mortality post-LVAD implantation. LVAD is a feasible, life-saving therapy for end-stage heart failure related to RCM, especially as a bridge to transplant and in patients with larger LV dimensions. Copyright © 2015 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

  19. A durability study of a paracorporeal pulsatile electro-mechanical pneumatic biventricular assist device.

    Science.gov (United States)

    Choi, Hyuk; Lee, Heung-Man; Nam, Kyoung Won; Choi, Jaesoon; Lee, Jung-Joo; Kim, Ho Chul; Song, Seung Joon; Ahn, Chi Bum; Son, Ho Sung; Lim, Choon Hak; Son, Kuk Hui; Park, Yong Doo; Jeong, Gi Seok; Sun, Kyung

    2011-06-01

    In 2002, the paracorporeal pulsatile electro-mechanical pneumatic ventricular assist device (VAD) began to be developed by the Korea Artificial Organ Center at Korea University under a Health & Medical Technology Research and Development program which finished in 2008. In vitro durability testing was conducted on the paracorporeal pulsatile pneumatic VAD to determine device durability and to evaluate device failures. The 1- and 2-year reliability of the paracorporeal pulsatile pneumatic VAD was shown to be 91.2% and 54.9%, respectively, with an 80% confidence level. Failure modes were analyzed using fault tree analysis, with customized software continuously acquiring data during the test period. After this period, 21 in vivo animal tests were done, with 14 cases of left atrium to left ventricle (LV) inflow cannulation (36Fr)/outflow grafting to descending aorta, and seven cases of apex cannulation of LV to descending aorta (12 mm). The longest postoperative day (182 days) in Korea was recently recorded in in vivo animal testing (bovine, 90 kg, male, 3.5-4.0 L/min flow rate, and 55 bpm). © 2011, Copyright the Authors. Artificial Organs © 2011, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  20. Mechanical circulatory assist device development at the Texas Heart Institute: a personal perspective.

    Science.gov (United States)

    Frazier, O H

    2014-01-01

    In December 2013, we performed our 1000th ventricular assist device implantation at the Texas Heart Institute. In my professional career, I have been fortunate to see the development of numerous mechanical circulatory support devices for the treatment of patients with advanced heart failure. In fact, most of the cardiac pumps in wide use today were developed in the Texas Heart Institute research laboratories in cooperation with the National Heart, Lung and Blood Institute or device innovators and manufacturers and implanted clinically at our partner St. Luke's Episcopal Hospital. My early involvement in this field was guided by my mentors, Dr Michael E. DeBakey and, especially, Dr Denton A. Cooley. Also, many of the advances are directly attributable to my ongoing clinical experience. What I learned daily in my surgical practice allowed me to bring insights to the development of this technology that a laboratory researcher alone might not have had. Young academic surgeons interested in this field might be well served to be active not only in laboratory research but also in clinical practice. Copyright © 2014 Elsevier Inc. All rights reserved.

  1. Efficient adders for assistive devices

    Directory of Open Access Journals (Sweden)

    Mansi Jhamb

    2017-02-01

    Full Text Available The Body sensor network [IEEE 802.15] is a wireless communication network consisting of assistive devices which are of prime importance in medical applications. The delay critical and power hungry blocks in these assistive devices are designed so that they consume less power, have low latency and require a lesser area on chip. In this paper, we present a qualitative as well as a quantitative analysis of an asynchronous pipelined adder design with two latest computation completion sensing approaches based on Pseudo NMOS logic and other based on C-element. The Pseudo NMOS based completion sensing approach provides a maximum improvement of 76.92% in critical path delay at supply voltage of 1.2 V and the maximum drop in power dissipation has been observed at a supply voltage of 1.1 V which is 85.60% as compared to C-element based completion sensing approach. Even at low voltages such as 0.8 V, there is a significant improvement in speed and power which is 75.64% and 74.79% respectively. Since the adder is the most widely used component in all present day assistive devices, this analysis acts as a pointer for the application of asynchronous pipelined circuits with efficient Pseudo NMOS based completion sensing approach in low voltage/low power rehabilitative devices.

  2. Influence of surgical implantation angle of left ventricular assist device outflow graft and management of aortic valve opening on the risk of stroke in heart failure patients

    Science.gov (United States)

    Chivukula, V. Keshav; McGah, Patrick; Prisco, Anthony; Beckman, Jennifer; Mokadam, Nanush; Mahr, Claudius; Aliseda, Alberto

    2016-11-01

    Flow in the aortic vasculature may impact stroke risk in patients with left ventricular assist devices (LVAD) due to severely altered hemodynamics. Patient-specific 3D models of the aortic arch and great vessels were created with an LVAD outflow graft at 45, 60 and 90° from centerline of the ascending aorta, in order to understand the effect of surgical placement on hemodynamics and thrombotic risk. Intermittent aortic valve opening (once every five cardiac cycles) was simulated and the impact of this residual native output investigated for the potential to wash out stagnant flow in the aortic root region. Unsteady CFD simulations with patient-specific boundary conditions were performed. Particle tracking for 10 cardiac cycles was used to determine platelet residence times and shear stress histories. Thrombosis risk was assessed by a combination of Eulerian and Lagrangian metrics and a newly developed thrombogenic potential metric. Results show a strong influence of LVAD outflow graft angle on hemodynamics in the ascending aorta and consequently on stroke risk, with a highly positive impact of aortic valve opening, even at low frequencies. Optimization of LVAD implantation and management strategies based on patient-specific simulations to minimize stroke risk will be presented

  3. Bi-level positive airway pressure ventilation for treating heart failure with central sleep apnea that is unresponsive to continuous positive airway pressure.

    Science.gov (United States)

    Dohi, Tomotaka; Kasai, Takatoshi; Narui, Koji; Ishiwata, Sugao; Ohno, Minoru; Yamaguchi, Tetsu; Momomura, Shin-Ichi

    2008-07-01

    Cheyne-Stokes respiration with central sleep apnea (CSR-CSA) is associated with a poor prognosis in patients with heart failure (HF). However, some patients do not respond to continuous positive airway pressure (CPAP), so other therapeutic modalities should be considered, such as bi-level positive airway pressure (PAP), which also assists respiration and might be effective for such patients. The 20 patients with HF because of left ventricular systolic dysfunction were assessed: 8 had ischemic etiology, and all had severe CSA according to the apnea - hypopnea index (AHI) determined by polysomnography. All diagnosed patients underwent repeat polysomnography using CPAP. The AHI improved significantly in 11 (AHI or=15). Bi-level PAP titration significantly improved the AHI in the latter group. Those who were unresponsive to CPAP had significantly lower PaCO(2), higher plasma brain natriuretic peptide (BNP), longer mean duration of CSR and fewer obstructive episodes than CPAP responders. After 6 months of positive airway support with either CPAP (n=9) or bi-level PAP (n=7), BNP levels significantly decreased and left ventricular ejection fraction significantly increased. Bi-level PAP could be an effective alternative for patients with HF and pure CSR-CSA who are unresponsive to CPAP.

  4. Ventricular assist device elicits serum natural IgG that correlates with the development of primary graft dysfunction following heart transplantation.

    Science.gov (United States)

    See, Sarah B; Clerkin, Kevin J; Kennel, Peter J; Zhang, Feifan; Weber, Matthew P; Rogers, Kortney J; Chatterjee, Debanjana; Vasilescu, Elena R; Vlad, George; Naka, Yoshifumi; Restaino, Susan W; Farr, Maryjane A; Topkara, Veli K; Colombo, Paolo C; Mancini, Donna M; Schulze, P Christian; Levin, Bruce; Zorn, Emmanuel

    2017-08-01

    Pre-transplant sensitization is a limiting factor in solid-organ transplantation. In heart transplants, ventricular assist device (VAD) implantation has been associated with sensitization to human leukocyte antigens (HLA). The effect of VAD on non-HLA antibodies is unclear. We have previously shown that polyreactive natural antibodies (Nabs) contribute to pre-sensitization in kidney allograft recipients. Here we assessed generation of Nabs after VAD implantation in pre-transplant sera and examined their contribution to cardiac allograft outcome. IgM and IgG Nabs were tested in pre-transplant serum samples collected from 206 orthotopic heart transplant recipients, including 128 patients with VAD (VAD patients) and 78 patients without VAD (no-VAD patients). Nabs were assessed by testing serum reactivity to apoptotic cells by flow cytometry and to the generic oxidized epitope, malondialdehyde, by enzyme-linked immunosorbent assay. No difference was observed in serum levels of IgM Nabs between VAD and no-VAD patients. However, serum IgG Nabs levels were significantly increased in VAD compared with no-VAD patients. This increase was likely due to the presence of the VAD, as revealed by lower serum IgG Nabs levels before implantation. Elevated pre-transplant IgG Nabs level was associated with development of primary graft dysfunction (PGD). Our study demonstrates that VAD support elicits IgG Nabs reactive to apoptotic cells and oxidized epitopes. These findings further support broad and non-specific B-cell activation by VAD, resulting in IgG sensitization. Moreover, the association of serum IgG Nabs levels with development of PGD suggests a possible role for these antibodies in the inflammatory reaction accompanying this complication. Copyright © 2017 International Society for the Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

  5. A Passively-Suspended Tesla Pump Left Ventricular Assist Device

    Science.gov (United States)

    Izraelev, Valentin; Weiss, William J.; Fritz, Bryan; Newswanger, Raymond K.; Paterson, Eric G.; Snyder, Alan; Medvitz, Richard B.; Cysyk, Joshua; Pae, Walter E.; Hicks, Dennis; Lukic, Branka; Rosenberg, Gerson

    2009-01-01

    The design and initial test results of a new passively suspended Tesla type LAVD blood pump are described. CFD analysis was used in the design of the pump. Overall size of the prototype device is 50 mm in diameter and 75 mm in length. The pump rotor has a density lower than that of blood and when spinning inside the stator in blood it creates a buoyant centering force that suspends the rotor in the radial direction. The axial magnetic force between the rotor and stator restrain the rotor in the axial direction. The pump is capable of pumping up to 10 liters/min at a 70 mmHg head rise at 8000 RPM. The pump has demonstrated a normalized index of hemolysis level below .02 mg/dL for flows between 2 and 9.7 L/min. An inlet pressure sensor has also been incorporated into the inlet cannula wall and will be used for control purposes. One initial in vivo study showed an encouraging result. Further CFD modeling refinements are planned as well as endurance testing of the device. PMID:19770799

  6. Facile Br{sup -} assisted hydrothermal synthesis of Bi{sub 2}MoO{sub 6} nanoplates with enhanced visible-light photocatalytic activity

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Peng [Yangtze Normal University, Chongqing Key Laboratory of Inorganic Special Functional Materials, Chongqing (China); Yangtze Normal University, College of Chemistry and Chemical Engineering, Chongqing (China); Teng, Xiaoxu; Liu, Dongsheng; Fu, Liang; Xie, Hualin [Yangtze Normal University, College of Chemistry and Chemical Engineering, Chongqing (China); Zhang, Guoqing [Yangtze Normal University, Chongqing Key Laboratory of Inorganic Special Functional Materials, Chongqing (China); Ding, Shimin [Yangtze Normal University, Collaborative Innovation Center for Green Development in Wuling Mountain Areas, Chongqing (China)

    2017-10-15

    Bi{sub 2}MoO{sub 6} nanoplates have been controllably synthesized via a facile hydrothermal process with the assistance of Br{sup -} containing surfactant cetyltrimethylammonium bromide (CTAB) or KBr. A remarkable enhancement in the visible-light-driven photocatalytic degradation of Rhodamine B was observed. It was found that reaction temperature and surfactant play crucial roles in the formation and properties of the Bi{sub 2}MoO{sub 6} nanoplates. The best results as photocatalyst were obtained with the sample hydrothermally synthesized at 150 C with the assistance of CTAB. The improved photocatalytic performance could be ascribed to the {001}-oriented nanostructure of the Bi{sub 2}MoO{sub 6} nanoplates. KBr-templated Bi{sub 2}MoO{sub 6} nanoplates also showed better photocatalytic efficiency compared with that of flower-like Bi{sub 2}MoO{sub 6} but inferior to that of CTAB-templated Bi{sub 2}MoO{sub 6} nanoplates. (orig.)

  7. Impact of Socioeconomic Status on Patients Supported With a Left Ventricular Assist Device: An Analysis of the UNOS Database (United Network for Organ Sharing).

    Science.gov (United States)

    Clerkin, Kevin J; Garan, Arthur Reshad; Wayda, Brian; Givens, Raymond C; Yuzefpolskaya, Melana; Nakagawa, Shunichi; Takeda, Koji; Takayama, Hiroo; Naka, Yoshifumi; Mancini, Donna M; Colombo, Paolo C; Topkara, Veli K

    2016-10-01

    Low socioeconomic status (SES) is a known risk factor for heart failure, mortality among those with heart failure, and poor post heart transplant (HT) outcomes. This study sought to determine whether SES is associated with decreased waitlist survival while on left ventricular assist device (LVADs) support and after HT. A total of 3361 adult patients bridged to primary HT with an LVAD between May 2004 and April 2014 were identified in the UNOS database (United Network for Organ Sharing). SES was measured using the Agency for Healthcare Research and Quality SES index using data from the 2014 American Community Survey. In the study cohort, SES did not have an association with the combined end point of death or delisting on LVAD support (P=0.30). In a cause-specific unadjusted model, those in the top (hazard ratio, 1.55; 95% confidence interval, 1.14-2.11; P=0.005) and second greatest SES quartile (hazard ratio 1.50; 95% confidence interval, 1.10-2.04; P=0.01) had an increased risk of death on device support compared with the lowest SES quartile. Adjusting for clinical risk factors mitigated the increased risk. There was no association between SES and complications. Post-HT survival, both crude and adjusted, was decreased for patients in the lowest quartile of SES index compared with all other SES quartiles. Freedom from waitlist death or delisting was not affected by SES. Patients with a higher SES had an increased unadjusted risk of waitlist mortality during LVAD support, which was mitigated by adjusting for increased comorbid conditions. Low SES was associated with worse post-HT outcomes. Further study is needed to confirm and understand a differential effect of SES on post-transplant outcomes that was not seen during LVAD support before HT. © 2016 American Heart Association, Inc.

  8. Mixed bi-material electrodes based on LiMn2O4 and activated carbon for hybrid electrochemical energy storage devices

    International Nuclear Information System (INIS)

    Cericola, Dario; Novak, Petr; Wokaun, Alexander; Koetz, Ruediger

    2011-01-01

    Highlights: → Bi-material electrodes for electrochemical hybrid devices were characterized. → Bi-material electrodes have higher specific charge than capacitor electrodes. → Bi-material electrodes have better rate capability than battery electrodes. → Bi-material systems outperform batteries and capacitors in pulsed applications. - Abstract: The performance of mixed bi-material electrodes composed of the battery material, LiMn 2 O 4 , and the electrochemical capacitor material, activated carbon, for hybrid electrochemical energy storage devices is investigated by galvanostatic charge/discharge and pulsed discharge experiments. Both, a high and a low conductivity lithium-containing electrolyte are used. The specific charge of the bi-material electrode is the linear combination of the specific charges of LiMn 2 O 4 and activated carbon according to the electrode composition at low discharge rates. Thus, the specific charge of the bi-material electrode falls between the specific charge of the activated carbon electrode and the LiMn 2 O 4 battery electrode. The bi-material electrodes have better rate capability than the LiMn 2 O 4 battery electrode. For high current pulsed applications the bi-material electrodes typically outperform both the battery and the capacitor electrode.

  9. Graves' disease presenting as bi-ventricular heart failure with severe pulmonary hypertension and pre-eclampsia in pregnancy--a case report and review of the literature.

    Science.gov (United States)

    Sabah, Khandker Mohammad Nurus; Chowdhury, Abdul Wadud; Islam, Mohammad Shahidul; Cader, Fathima Aaysha; Kawser, Shamima; Hosen, Md Imam; Saleh, Mohammed Abaye Deen; Alam, Md Shariful; Chowdhury, Mohammad Monjurul Kader; Tabassum, Humayara

    2014-11-18

    Graves' disease, a well-known cause of hyperthyroidism, is an autoimmune disease with multi-system involvement. More prevalent among young women, it appears as an uncommon cardiovascular complication during pregnancy, posing a diagnostic challenge, largely owing to difficulty in detecting the complication, as a result of a low index of suspicion of Graves' disease presenting during pregnancy. Globally, cardiovascular disease is an important factor for pregnancy-related morbidity and mortality. Here, we report a case of Graves' disease detected for the first time in pregnancy, in a patient presenting with bi- ventricular heart failure, severe pulmonary hypertension and pre- eclampsia. Emphasis is placed on the spectrum of clinical presentations of Graves' disease, and the importance of considering this thyroid disorder as a possible aetiological factor for such a presentation in pregnancy. A 30-year-old Bangladeshi-Bengali woman, in her 28th week of pregnancy presented with severe systemic hypertension, bi-ventricular heart failure and severe pulmonary hypertension with a moderately enlarged thyroid gland. She improved following the administration of high dose intravenous diuretics, and delivered a premature female baby of low birth weight per vaginally, twenty four hours later. Pre-eclampsia was diagnosed on the basis of hypertension first detected in the third trimester, 3+ oedema and mild proteinuria. Electrocardiography revealed sinus tachycardia with incomplete right bundle branch block and echocardiography showed severe pulmonary hypertension with an estimated pulmonary arterial systolic pressure of 73 mm Hg, septal and anterior wall hypokinesia with an ejection fraction of 51%, grade I mitral and tricuspid regurgitation. Thyroid function tests revealed a biochemically hyperthyroid state and positive anti- thyroid peroxidase antibodies was found. (99m)Technetium pertechnetate thyroid scans demonstrated diffuse toxic goiter as evidenced by an enlarged thyroid

  10. Patent ductus arteriosus closure using an Amplatzer™ ventricular septal defect closure device

    Science.gov (United States)

    Fernando, Rajeev; Koranne, Ketan; Loyalka, Pranav; Kar, Biswajit; Gregoric, Igor

    2013-01-01

    The ductus arteriosus originates from the persistence of the distal portion of the left sixth aortic arch. It connects the descending aorta (immediately distal to the left subclavian artery) to the roof of the main pulmonary artery, near the origin of the left pulmonary artery. Persistence of the duct beyond 48 h after birth is abnormal and results in patent ductus arteriosus (PDA). PDA is rare in adults because it is usually discovered and treated in childhood. Mechanical closure remains the definitive therapy because the patency of ductus arteriosus may lead to multiple complications, depending on the size and flow through the ductus. PDA closure is indicated in patients with symptoms and evidence of left heart enlargement, and in patients with elevated pulmonary pressures when reversal is possible. Transcatheter closure is the preferred technique in adults because it avoids sternotomy, reduces the length of hospital stay and is associated with fewer complications compared with surgery. First demonstrated in 1967, both the technique and the occluder devices used have since evolved. However, designing an ideal PDA occluder has been a challenge due to the variability in size, shape and orientation of PDAs. The present article describes a case involving a 35-year-old woman who presented to the Center for Advanced Heart Failure (Houston, USA) with congestive heart failure due to a large PDA, which was successfully occluded using an Amplatzer (St Jude Medical, USA) muscular ventricular septal defect closure device. The wider waist and dual-retention discs of these ventricular septal defect closure devices may be important factors to consider in the future development of devices for the occlusion of large PDAs. PMID:24294051

  11. Hemodynamic stress echocardiography in patients supported with a continuous-flow left ventricular assist device

    DEFF Research Database (Denmark)

    Andersen, Mads Jønsson; Gustafsson, Finn; Madsen, Per Lav

    2010-01-01

    exercise. Exercise induced an increase in cardiac output, systolic pulmonary artery pressure, and diastolic pulmonary artery pressure. Although no changes in left ventricular dimensions or fractional shortening were seen on echocardiography, systolic mitral annular motion (S') increased significantly (in...... parallel with cardiac output) and diastolic E/e' ratio decreased (correlating inversely with diastolic pulmonary artery pressure). These findings emphasize the potential role of exercise echocardiography in studying exercise hemodynamics in LVAD patients....

  12. Rapid adsorption properties of flower-like BiOI nanoplates synthesized via a simple EG-assisted solvothermal process

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Bin; Ji, Guangbin, E-mail: gbji@nuaa.edu.cn [Nanjing University of Aeronautics and Astronautics, College of Materials Science and Technology (China); Gondal, M. A. [King Fahd University of Petroleum and Minerals, Physics Department (Saudi Arabia); Liu, Yousong; Zhang, Xingmiao; Chang, Xiaofeng; Li, Nianwu [Nanjing University of Aeronautics and Astronautics, College of Materials Science and Technology (China)

    2013-07-15

    Uniform well-crystallized flower-like BiOI nanoplates contained 3.7 nm mesopores, which may be attributed to the internanosheet spaces of BiOI with maximum pore diameters of about 30 nm, were successfully synthesized via a simple ethylene glycol-assisted solvothermal method. The as-prepared porous BiOI nanoplates exhibited excellent adsorption ability, and the saturated extent of adsorption of BiOI over an RhB solution was as high as 197 mg/g, which is much higher than those for BiOCl and BiOBr prepared via the same method and with a similar surface area. The probable adsorption mechanism could have originated from the interaction between the I atom in BiOI and a proton in RhB at different pH values and temperatures. With visible light irradiation ({lambda} > 420 nm), 80 % of the RhB was degraded in 4 h, while BiOI still demonstrated reasonably outstanding photocatalytic ability under green light ({lambda} = 550 {+-} 15 nm) because of its low-energy gap (1.72 eV). The degradation test for BiOI under irradiation at {lambda} = 550 {+-} 15 nm is an excellent achievement for field applications because the catalyst can be applied in solar irradiation to remove organic pollutants, which may be of great value BiOI complex.

  13. Exercise Capacity and Functional Performance in Heart Failure Patients Supported by a Left Ventricular Assist Device at Discharge From Inpatient Rehabilitation.

    Science.gov (United States)

    Schmidt, Thomas; Bjarnason-Wehrens, Birna; Bartsch, Petra; Deniz, Ezin; Schmitto, Jan; Schulte-Eistrup, Sebastian; Willemsen, Detlev; Reiss, Nils

    2018-01-01

    Adequate physical and functional performance is an important prerequisite for renewed participation and integration in self-determined private and (where appropriate) professional lives following left ventricular assist device (LVAD) implantation. During cardiac rehabilitation (CR), individually adapted exercise programs aim to increase exercise capacity and functional performance. A retrospective analysis of cardiopulmonary exercise capacity and functional performance in LVAD patients at discharge from a cardiac rehabilitation program was conducted. The results from 68 LVAD patients (59 males, 9 females; 55.9 ± 11.7 years; 47 HVAD, 2 MVAD, 15 HeartMate II, 4 HeartMate 3, and 4 different implanting centers) were included in the analysis. Exercise capacity was assessed using a cardiopulmonary exercise test on a bicycle ergometer (ramp protocol; 10 W/min). The 6-min walk test was used to determine functional performance. At discharge from CR (53 ± 17 days after implantation), the mean peak work load achieved was 62.2 ± 19.3 W (38% of predicted values) or 0.79 ± 0.25 W/kg body weight. The mean cardiopulmonary exercise capacity (relative peak oxygen uptake) was 10.6 ± 5.3 mL/kg/min (37% of predicted values). The 6-min walk distance improved significantly during CR (325 ± 106 to 405 ± 77 m; P exercise capacity remains considerably restricted. In contrast, functional performance, measured by the 6-min walk distance, reaches an acceptable level. Light everyday tasks seem to be realistically surmountable for patients, making discharge from inpatient rehabilitation possible. Long-term monitoring is required in order to evaluate the situation and how it develops further. © 2017 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  14. Flow Visualization Studies in the Novacor Left Ventricular Assist System CRADA PC91-002, Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Borovetz, H.S.; Shaffer, F.; Schaub, R.; Lund, L.; Woodard, J.

    1999-01-01

    This paper discusses a series of experiments to visualize and measure flow fields in the Novacor left ventricular assist system (LVAS). The experiments utilize a multiple exposure, optical imaging technique called fluorescent image tracking velocimetry (FITV) to hack the motion of small, neutrally-buoyant particles in a flowing fluid.

  15. Advances in bioartificial liver assist devices.

    Science.gov (United States)

    Patzer, J F

    2001-11-01

    Rapid advances in development of bioartificial liver assist devices (BLADs) are exciting clinical interest in the application of BLAD technology for support of patients with acute liver failure. Four devices (Circe Biomedical HepatAssist, Vitagen ELAD, Gerlach BELS, and Excorp Medical BLSS) that rely on hepatocytes cultured in hollow-fiber membrane technology are currently in various stages of clinical evaluation. Several alternative approaches for culture and perfusion of hepatocytes have been evaluated in preclinical, large animal models of liver failure, or at a laboratory scale. Engineering design issues with respect to xenotransplantation, BLAD perfusion, hepatocyte functionality and culture maintenance, and ultimate distribution of a BLAD to a clinical site are delineated.

  16. Single-center experience of the bridge-to-bridge strategy using the Nipro paracorporeal ventricular assist device.

    Science.gov (United States)

    Yoshitake, Shuichi; Kinoshita, Osamu; Nawata, Kan; Hoshino, Yasuhiro; Itoda, Yoshifumi; Kimura, Mitsutoshi; Yamauchi, Haruo; Ono, Minoru

    2018-06-25

    Currently, we use the Nipro paracorporeal VAD (p-VAD) for initial short-term ventricular support, as a bridge to decision (BTD) or a bridge to candidacy (BTC) treatment, in Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) levels 1 and 2 patients. However, it is possible that compared to patients with primary implantable-VADs (P-iVAD), the bridge-to-bridge (BTB) patients are more likely to develop complications. This retrospective study used data from 24 consecutive BTB patients who were initially implanted with Nipro p-VAD as BTD or BTC treatments between April 2011 and March 2016, and subsequently underwent conversion to an i-VAD. The data from 72 patients who underwent a primary i-VAD (P-iVAD) procedure were used for comparison. Between the two groups, there was no significant difference in the incidence of infectious events (p = 0.72) or stroke (p = 0.44). Orthotropic heart transplantation was performed in 6 of the 24 patients in the BTB group and in 21 of the 72 patients in the P-iVAD group. The 1- and 2-year survival rates were 95.8% and 95.8% in the BTB group and 91% and 85.8% in the P-iVAD group; these values were not significantly different between groups (p = 0.91). Based on these results we conclude that BTB using Nipro p-VAD is a reasonable strategy for treating patients with severe decompensated end-stage heart failure.

  17. Patent ductus arteriosus closure using an Amplatzer(™) ventricular septal defect closure device.

    Science.gov (United States)

    Fernando, Rajeev; Koranne, Ketan; Loyalka, Pranav; Kar, Biswajit; Gregoric, Igor

    2013-01-01

    The ductus arteriosus originates from the persistence of the distal portion of the left sixth aortic arch. It connects the descending aorta (immediately distal to the left subclavian artery) to the roof of the main pulmonary artery, near the origin of the left pulmonary artery. Persistence of the duct beyond 48 h after birth is abnormal and results in patent ductus arteriosus (PDA). PDA is rare in adults because it is usually discovered and treated in childhood. Mechanical closure remains the definitive therapy because the patency of ductus arteriosus may lead to multiple complications, depending on the size and flow through the ductus. PDA closure is indicated in patients with symptoms and evidence of left heart enlargement, and in patients with elevated pulmonary pressures when reversal is possible. Transcatheter closure is the preferred technique in adults because it avoids sternotomy, reduces the length of hospital stay and is associated with fewer complications compared with surgery. First demonstrated in 1967, both the technique and the occluder devices used have since evolved. However, designing an ideal PDA occluder has been a challenge due to the variability in size, shape and orientation of PDAs. The present article describes a case involving a 35-year-old woman who presented to the Center for Advanced Heart Failure (Houston, USA) with congestive heart failure due to a large PDA, which was successfully occluded using an Amplatzer (St Jude Medical, USA) muscular ventricular septal defect closure device. The wider waist and dual-retention discs of these ventricular septal defect closure devices may be important factors to consider in the future development of devices for the occlusion of large PDAs.

  18. Translation and validation of the assistive technology device predisposition assessment in Greek in order to assess satisfaction with use of the selected assistive device.

    Science.gov (United States)

    Koumpouros, Yiannis; Papageorgiou, Effie; Karavasili, Alexandra; Alexopoulou, Despoina

    2017-07-01

    To examine the Assistive Technology Device Predisposition Assessment scale and provide evidence of validity and reliability of the Greek version. We translated and adapted the original instrument in Greek according to the most well-known guidelines recommendations. Field test studies were conducted in a rehabilitation hospital to validate the appropriateness of the final results. Ratings of the different items were statistically analyzed. We recruited 115 subjects who were administered the Form E of the original questionnaire. The experimental analysis conducted revealed a three subscales structure: (i) Adaptability, (ii) Fit to Use, and (iii) Socializing. According to the results of our study the three subscales measure different constructs. Reliability measures (ICC = 0.981, Pearson's correlation = 0.963, Cronbach's α = 0.701) yielded high values. Test-retest outcome showed great stability. This is the first study, at least to the knowledge of the authors, which focuses merely on measuring the satisfaction of the users from the used assistive device, while exploring the Assistive Technology Device Predisposition Assessment - Device Form in such depth. According to the results, it is a stable, valid and reliable instrument and applicable to the Greek population. Thus, it can be used to measure the satisfaction of patients with assistive devices. Implications for Rehabilitation The paper explores the cultural adaptability and applicability of ATD PA - Device Form. ATD PA - Device Form can be used to assess user satisfaction by the selected assistive device. ATD PA - Device Form is a valid and reliable instrument in measuring users' satisfaction in Greekreality.

  19. Fabrication and Characterization of Bi2Te3-Based Chip-Scale Thermoelectric Energy Harvesting Devices

    Science.gov (United States)

    Cornett, Jane; Chen, Baoxing; Haidar, Samer; Berney, Helen; McGuinness, Pat; Lane, Bill; Gao, Yuan; He, Yifan; Sun, Nian; Dunham, Marc; Asheghi, Mehdi; Goodson, Ken; Yuan, Yi; Najafi, Khalil

    2017-05-01

    Thermoelectric energy harvesters convert otherwise wasted heat into electrical energy. As a result, they have the potential to play a critical role in the autonomous wireless sensor network signal chain. In this paper, we present work carried out on the development of Bi2Te3-based thermoelectric chip-scale energy harvesting devices. Process flow, device demonstration and characterization are highlighted.

  20. VENTRICLE ASSIST DEVICE: PAST, PRESENT, AND FUTURE NONPULSATILE PUMPS

    Directory of Open Access Journals (Sweden)

    G. Р. Itkin

    2009-01-01

    Full Text Available The article briefly describes the history of the non-pulsating type blood pumps for ventricular assist circulation and heart-lung machine. Disclosed the main advantages of these pumps before pulsating type, especially for implantable systems development. However, disadvantages of these pumps and the directions of minimize or eliminate ones have shown. Specific examples of our implantable centrifugal and axial pump developments are presented. Declare the ways to further improve the pumps. 

  1. Non-Exposure, Device-Assisted Endoscopic Full-thickness Resection.

    Science.gov (United States)

    Bauder, Markus; Schmidt, Arthur; Caca, Karel

    2016-04-01

    Recent developments have expanded the frontier of interventional endoscopy toward more extended resections following surgical principles. This article presents two new device-assisted techniques for endoscopic full-thickness resection in the upper and lower gastrointestinal tract. Both methods are nonexposure techniques avoiding exposure of gastrointestinal contents to the peritoneal cavity by a "close first-cut later" principle. The full-thickness resection device is a novel over-the-scope device designed for clip-assisted full-thickness resection of colorectal lesions. Endoscopic full-thickness resection of gastric subepithelial tumors can be performed after placing transmural sutures underneath the tumor with a suturing device originally designed for endoscopic antireflux therapy. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Proximal thoracic aorta dimensions after continuous-flow left ventricular assist device implantation: Longitudinal changes and relation to aortic valve insufficiency.

    Science.gov (United States)

    Fine, Nowell M; Park, Soon J; Stulak, John M; Topilsky, Yan; Daly, Richard C; Joyce, Lyle D; Pereira, Naveen L; Schirger, John A; Edwards, Brooks S; Lin, Grace; Kushwaha, Sudhir S

    2016-04-01

    In this study we examined the impact of continuous-flow left ventricular assist device (CF-LVAD) support on proximal thoracic aorta dimensions. Aortic root and ascending aorta diameter were measured from serial echocardiograms before and after CF-LVAD implantation in patients with ≥6 months of support, and correlated with the development of >mild aortic valve insufficiency (AI). Of 162 patients included, mean age was 58 ± 11 years and 128 (79%) were male. Seventy-nine (63%) were destination therapy patients. Mean aortic root and ascending aorta diameters at baseline, 1 month, 6 months, 12 months and long-term follow-up (mean 2.0 ± 1.4 years) were 3.5 ± 0.4, 3.5 ± 0.3, 3.9 ± 0.3, 3.9 ± 0.2 and 4.0 ± 0.3, and 3.3 ± 0.2, 3.3 ± 0.3, 3.6 ± 0.2, 3.6 ± 0.3 and 3.6 ± 0.3 cm, respectively. Only change in aortic root diameter from 1-month to 6-month follow-up reached statistical significance (p = 0.03). Nine (6%) patients had accelerated proximal thoracic aorta expansion (>0.5 cm/year), occurring predominantly in the first 6 months after implantation. These patients were older and more likely to have hypertension and baseline proximal thoracic aorta dilation. Forty-five (28%) patients developed >mild AI at long-term follow-up, including 7 of 9 (78%) of those with accelerated proximal thoracic aorta expansion. All 7 had aortic valves that remained closed throughout the cardiac cycle, and this, along with duration of CF-LVAD support and increase in aortic root diameter, were significantly associated with developing >mild AI. CF-LVAD patients have small increases in proximal thoracic aorta dimensions that predominantly occur within the first 6 months after implantation and then stabilize. Increasing aortic root diameter was associated with AI development. Copyright © 2016 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

  3. Hemodynamic deterioration precedes onset of ventricular tachyarrhythmia after Heartmate II implantation.

    Science.gov (United States)

    Yaksh, Ameeta; Kik, Charles; Knops, Paul; Zwiers, Korinne; van Ettinger, Maarten J B; Manintveld, Olivier C; de Wijs, Marcel C J; van der Kemp, Peter; Bogers, Ad J J C; de Groot, Natasja M S

    2016-07-08

    Early postoperative ventricular tachyarrhythmia (PoVT) after left ventricular assist device (LVAD) implantation are common and associated with higher mortality-rates. At present, there is no data on initiation of these PoVT and the role of alterations in cardiac hemodynamics. A LVAD was implanted in a patient with end-stage heart failure due to a ischemic cardiomyopathy. Alterations in cardiac rhythm and hemodynamics preceding PoVT-episodes during the first five postoperative days were examined by using continuous recordings of cardiac rhythm and various hemodynamic parameters. All PoVT (N=120) were monomorphic, most often preceded by short-long-short-sequences or regular SR and initiated by ventricular runs. Prior to PoVT, mean arterial pressure decreased; heart rate and ST-segments deviations increased. PoVT are caused by different underlying electrophysiological mechanisms. Yet, they are all monomorphic and preceded by hemodynamic deterioration due to myocardial ischemia.

  4. Renal Function and Outcomes With Use of Left Ventricular Assist Device Implantation and Inotropes in End-Stage Heart Failure: A Retrospective Single Center Study.

    Science.gov (United States)

    Verma, Sean; Bassily, Emmanuel; Leighton, Shane; Mhaskar, Rahul; Sunjic, Igor; Martin, Angel; Rihana, Nancy; Jarmi, Tambi; Bassil, Claude

    2017-07-01

    Left ventricular assist device (LVAD) and inotrope therapy serve as a bridge to transplant (BTT) or as destination therapy in patients who are not heart transplant candidates. End-stage heart failure patients often have impaired renal function, and renal outcomes after LVAD therapy versus inotrope therapy have not been evaluated. In this study, 169 patients with continuous flow LVAD therapy and 20 patients with continuous intravenous inotrope therapy were analyzed. The two groups were evaluated at baseline and at 3 and 6 months after LVAD or inotrope therapy was started. The incidence of acute kidney injury (AKI), need for renal replacement therapy (RRT), BTT rate, and mortality for 6 months following LVAD or inotrope therapy were studied. Results between the groups were compared using Mann-Whitney U test and Chi-square with continuity correction or Fischer's exact at the significance level of 0.05. Mean glomerular filtration rate (GFR) was not statistically different between the two groups, with P = 0.471, 0.429, and 0.847 at baseline, 3 and 6 months, respectively. The incidence of AKI, RRT, and BTT was not statistically different. Mortality was less in the inotrope group (P < 0.001). Intravenous inotrope therapy in end-stage heart failure patients is non-inferior for mortality, incidence of AKI, need for RRT, and renal function for 6-month follow-up when compared to LVAD therapy. Further studies are needed to compare the effectiveness of inotropes versus LVAD implantation on renal function and outcomes over a longer time period.

  5. Comparison between mono-bloc and bi-bloc mandibular advancement devices for obstructive sleep apnea.

    Science.gov (United States)

    Lee, Woo Hyun; Wee, Jee Hye; Lee, Chul Hee; Kim, Min-Su; Rhee, Chae-Seo; Yun, Pil-Young; Yoon, In-Young; Kim, Jeong-Whun

    2013-11-01

    Although mandibular advancement device (MAD) is widely used, there are a few papers comparing the efficacy and compliance at the same time according to the type of MAD. The aim of this study is to compare the efficacy and compliance between mono-bloc and bi-bloc MAD in the treatment of obstructive sleep apnea (OSA). Ninety-three patients who treated with mono-bloc MAD and 60 patients with bi-bloc MAD from January 2007 through September 2011 were retrospectively enrolled. All the patients underwent full-night polysomnography(PSG) before and 3 months after MAD was applied. The response rate was significantly higher in the patients using mono-bloc than those using bi-bloc MAD (77.4 vs. 58.3 %; P = 0.012). In contrast, the compliance rate of MAD use was significantly higher in the patients using bi-bloc than those using mono-bloc MAD (68.8 vs. 83.3 %; P = 0.044) at 1 year. According to the severity of OSA, the response rate was significantly higher in severe OSA than in mild to moderate OSA (P = 0.033 for mono-bloc MAD and P = 0.048 for bi-bloc MAD). However, there was no difference in the compliance between mild to moderate OSA and severe OSA. Our study showed that mono-bloc MAD was superior to bi-bloc MAD in efficacy while bi-bloc MAD is superior to mono-bloc MAD in compliance. We propose that both the efficacy and compliance should be considered in using MAD for treatment of OSA.

  6. Novel Method for Exchange of Impella Circulatory Assist Catheter: The "Trojan Horse" Technique.

    Science.gov (United States)

    Phillips, Colin T; Tamez, Hector; Tu, Thomas M; Yeh, Robert W; Pinto, Duane S

    2017-07-01

    Patients with an indwelling Impella may require escalation of hemodynamic support or exchange to another circulatory assistance platform. As such, preservation of vascular access is preferable in cases where anticoagulation cannot be discontinued or to facilitate exchange to an alternative catheter or closure device. Challenges exist in avoiding bleeding and loss of wire access in these situations. We describe a single-access "Trojan Horse" technique that minimizes bleeding while maintaining arterial access for rapid exchange of this percutaneous ventricular assist device.

  7. Biomolecule-Assisted Hydrothermal Synthesis and Self-Assembly of Bi2Te3 Nanostring-Cluster Hierarchical Structure

    DEFF Research Database (Denmark)

    Mi, Jianli; Lock, Nina; Sun, Ting

    2010-01-01

    A simple biomolecule-assisted hydrothermal approach has been developed for the fabrication of Bi2Te3 thermoelectric nanomaterials. The product has a nanostring-cluster hierarchical structure which is composed of ordered and aligned platelet-like crystals. The platelets are100 nm in diameter...

  8. Partial LVAD restores ventricular outputs and normalizes LV but not RV stress distributions in the acutely failing heart in silico

    OpenAIRE

    Sack, Kevin L.; Baillargeon, Brian; Acevedo-Bolton, Gabriel; Genet, Martin; Rebelo, Nuno; Kuhl, Ellen; Klein, Liviu; Weiselthaler, Georg M.; Burkhoff, Daniel; Franz, Thomas; Guccione, Julius M.

    2016-01-01

    Purpose: Heart failure is a worldwide epidemic that is unlikely to change as the population ages and life expectancy increases. We sought to detail significant recent improvements to the Dassault Systèmes Living Heart Model (LHM) and use the LHM to compute left ventricular (LV) and right ventricular (RV) myofiber stress distributions under the following 4 conditions: (1) normal cardiac function; (2) acute left heart failure (ALHF); (3) ALHF treated using an LV assist device (LVAD) flow rate o...

  9. Evaluation of Automated Flagger Assistance Devices

    Science.gov (United States)

    2018-02-01

    Automated flagger assistance devices (AFADs) are designed to improve worker safety by replacing flaggers who are typically located near traffic approaching a work zone. In this study, a new AFAD developed by the Missouri Department of Transportation ...

  10. Microwave-assisted solvothermal synthesis of flower-like Ag/AgBr/BiOBr microspheres and their high efficient photocatalytic degradation for p-nitrophenol

    International Nuclear Information System (INIS)

    Li, Tingting; Luo, Shenglian; Yang, Lixia

    2013-01-01

    Flower-like Ag/AgBr/BiOBr microspheres were successfully fabricated by the approach of microwave-assisted solvothermal and in situ photo-assisted reduction. A reactive ionic liquid 1-hexadecyl-3-methylimidazolium bromide ([C 16 mim]Br) was employed as Br source in the presence of surfactant polyvinylpyrrolidone (PVP). The photocatalytic activity of Ag/AgBr/BiOBr towards the decomposition of p-nitrophenol under visible light irradiation was evaluated. The results indicated that Ag/AgBr/BiOBr showed enhanced photocatalytic activity towards p-nitrophenol, comparing with P25, BiOBr and Ag/AgBr. More than 96% of p-nitrophenol was decomposed in 3.5 h under visible-light irradation. The excellent photocatalytic activity of flower-like Ag/AgBr/BiOBr microspheres can be attributed to the large specific surface area, strong visible-light absorption, suitable energy band structure and surface plasmon resonance effect of Ag nanoparticles. The possible photocatalytic mechanism was proposed based on the active species test and band gap structure analysis. - Graphical abstract: The photocatalytic reaction mechanisms of the as-prepared Ag/AgBr/BiOBr. Display Omitted - Highlights: • Successful synthesis of flower-like Ag/AgBr/BiOBr microspheres. • The Ag/AgBr/BiOBr showed much higher photocatalytic activity towards p-nitrophenol as compared to BiOBr and Ag/AgBr. • The reasons for the excellent photocatalytic activity are the large specific surface area, strong visible-light absorption and surface plasmon resonance effect of Ag nanoparticles. • The O 2 · − , Br 0 and photogenerated h + play key roles in the photocatalytic degradation process

  11. A monitoring device for pressurised-air-driven diaphragm-based artificial heart assist devices

    NARCIS (Netherlands)

    Hoeben, F.P.; Hoeben, F.P.; de Mul, F.F.M.; Stokkink, J.S.D.; Stokkink, H.S.D.; Koelink, M.H.; Koelink, M.H.; Greve, Jan

    1992-01-01

    A non-invasive device has been developed to monitor the diaphragm position and the blood flow in artificial heart assist devices equipped with a pressurised-air-driven diaphragm. Light scattering from the diaphragm is used as a mechanism for measuring. Information about the position of several

  12. Amiodarone for the treatment and prevention of ventricular fibrillation and ventricular tachycardia

    Directory of Open Access Journals (Sweden)

    Hugo Van Herendael

    2010-06-01

    Full Text Available Hugo Van Herendael, Paul DorianDivision of Cardiology, St. Michael’s Hospital, University of Toronto, Toronto, CanadaAbstract: Amiodarone has emerged as the leading antiarrhythmic therapy for termination and prevention of ventricular arrhythmia in different clinical settings because of its proven efficacy and safety. In patients with shock refractory out-of-hospital cardiac arrest and hemodynamically destabilizing ventricular arrhythmia, amiodarone is the most effective drug available to assist in resuscitation. Although the superiority of the transvenous implantable cardioverter defibrillator (ICD over amiodarone has been well established in the preventive treatment of patients at high risk of life-threatening ventricular arrhythmias, amiodarone (if used with a beta-blocker is the most effective antiarrhythmic drug to prevent ICD shocks and treat electrical storm. Both the pharmacokinetics and the electrophysiologic profile of amiodarone are complex, and its optimal and safe use requires careful patient surveillance with respect to potential adverse effects.Keywords: amiodarone, ventricular fibrillation, unstable ventricular tachycardia

  13. Microwave-assisted in situ synthesis of reduced graphene oxide-BiVO{sub 4} composite photocatalysts and their enhanced photocatalytic performance for the degradation of ciprofloxacin

    Energy Technology Data Exchange (ETDEWEB)

    Yan, Yan [School of Chemistry and Chemical Engineering, Jiangsu University, Xuefu Road 301, Zhenjiang, 212013 (China); Sun, Shaofang [School of Chemistry and Chemical Engineering, Jiangsu University, Xuefu Road 301, Zhenjiang, 212013 (China); School of Environmental Science and Engineering, Chang’an University, Yanta Road 126, Xi’an, 710054 (China); Song, Yang; Yan, Xu [School of Chemistry and Chemical Engineering, Jiangsu University, Xuefu Road 301, Zhenjiang, 212013 (China); Guan, Weisheng [School of Environmental Science and Engineering, Chang’an University, Yanta Road 126, Xi’an, 710054 (China); Liu, Xinlin [School of Material Science and Engineering, Jiangsu University, Xuefu Road 301, Zhenjiang, 212013 (China); Shi, Weidong, E-mail: swd1978@ujs.edu.cn [School of Chemistry and Chemical Engineering, Jiangsu University, Xuefu Road 301, Zhenjiang, 212013 (China)

    2013-04-15

    Highlights: ► Microwave-assisted in situ growth of RGO-BiVO{sub 4} composite was proposed. ► A relatively small particle size with organic-additives free. ► Graphene was formed during the microwave-heating by oxygen capture. ► GB-2 sample exhibits the highest CIP degradation ratio (3 times over pure BiVO{sub 4}). ► The enhancements of activities result from the effective charge separation. -- Abstract: To improve the photodegradation efficiency for ciprofloxacin (CIP), a new-type microwave-assisted in situ growth method is developed for the preparation of reduced graphene oxide (RGO) -BiVO{sub 4} composite photocatalysts. The as-produced RGO-BiVO{sub 4} composite photocatalysts show extremely high enhancement of CIP degradation ratio over the pure BiVO{sub 4} photocatalyst under visible light. Specially, the 2 wt% RGO-BiVO{sub 4} composite photocatalyst exhibits the highest CIP degradation ratio (68.2%) in 60 min, which is over 3 times than that (22.7%) of the pure BiVO{sub 4} particles. The enhancement of photocatalytic activities of RGO-BiVO{sub 4} photocatalysts can be attributed to the effective separation of electron–hole pairs rather than the improvement of light absorption.

  14. A case of appropriate inappropriate device therapy: Hyperkalemia-induced ventricular oversensing

    Science.gov (United States)

    Oudit, Gavin Y; Cameron, Doug; Harris, Louise

    2008-01-01

    The present case describes a patient who received inappropriate, but potentially life-saving, therapy from her implantable cardioverter defibrillator (ICD) in the setting of acute hyperkalemia (plasma potassium concentration = 8 mM). Hyperkalemia was associated with the development of a slow sinusoidal ventricular tachycardia, at a rate of 100 beats/min to 125 beats/min (610 ms to 480 ms) in a patient who is pacemaker-dependent. There was associated fractionation of the ICD electrogram and T wave oversensing, leading to ventricular oversensing with resultant detection in the ventricular fibrillation rate zone. This was followed by shock therapy, even though the ventricular tachycardia rate was below the programmed detection rate of the ICD. The subsequent emergency treatment of the hyperkalemia normalized the electrogram, corrected the ventricular oversensing and arrhythmia, and restored rate-adaptive single-chamber ventricular pacing. PMID:18340383

  15. Continuous-flow cardiac assistance : effects on aortic valve function in a mock loop

    NARCIS (Netherlands)

    Tuzun, E.; Rutten, M.C.M.; Dat, M.; Kadipasaoglu, C.; Vosse, van de F.N.; Mol, de B.A.J.M.

    2011-01-01

    Background As the use of left ventricular assist devices (LVADs) to treat end-stage heart failure has become more widespread, leaflet fusion—with resul-tant aortic regurgitation—has been observed more frequently. To quantitatively assess the effects of nonpulsatile flow on aortic valve function, we

  16. Persistent blood stream infection in patients supported with a continuous-flow left ventricular assist device is associated with an increased risk of cerebrovascular accidents.

    Science.gov (United States)

    Trachtenberg, Barry H; Cordero-Reyes, Andrea M; Aldeiri, Molham; Alvarez, Paulino; Bhimaraj, Arvind; Ashrith, Guha; Elias, Barbara; Suarez, Erik E; Bruckner, Brian; Loebe, Matthias; Harris, Richard L; Zhang, J Yi; Torre-Amione, Guillermo; Estep, Jerry D

    2015-02-01

    Common adverse events in patients supported with Continuous-flow left ventricular assist devices (CF-LVAD) include infections and cerebrovascular accidents (CVA). Some studies have suggested a possible association between blood stream infection (BSI) and CVA. Medical records of patients who received Heartmate II (HMII) CF-LVADs in 2008-2012 at a single center were reviewed. CVA was categorized as either hemorrhagic (HCVA) or ischemic (ICVA). BSI was divided into persistent (pBSI) and nonpersistent (non-pBSI). pBSI was defined as BSI with the same organism on repeated blood culture >72 hours from initial blood culture despite antibiotics. Univariate and multivariate analyses were performed to determine predictors. A total of 149 patients had HMII implanted; 76% were male, and the overall mean age was 55.4 ± 13 years. There were a total of 19 (13%) patients who had CVA (7 HCVA and 12 ICVA) at a median of 295 days (range 5-1,096 days) after implantation. There were a total of 28 (19%) patients with pBSI and 17 (11%) patients with non-pBSI. Patients with pBSI had a trend toward greater BMI (31 kg/m(2) vs 27 kg/m(2); P = .09), and longer duration of support (1,019 d vs 371 d; P < .001) compared with those with non-pBSI. Persistent BSI was associated with an increased risk of mortality and with all-cause CVA on multivariate analysis (odds ratio [OR] 5.97; P = .003) as well as persistent Pseudomonas aeruginosa infection (OR 4.54; P = .048). Persistent BSI is not uncommon in patients supported by CF-LVAD and is highly associated with all-cause CVA and increased all-cause mortality. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. Clinical assessment of the effect of digital filtering on the detection of ventricular late potentials

    Directory of Open Access Journals (Sweden)

    P.R. Benchimol-Barbosa

    2002-11-01

    Full Text Available Ventricular late potentials are low-amplitude signals originating from damaged myocardium and detected on the body surface by ECG filtering and averaging. Digital filters present in commercial equipment may interfere with the ability of arrhythmia stratification. We compared 40-Hz BiSpec (BI and classical 40- to 250-Hz band-pass Butterworth bidirectional (BD filters in terms of impact on time domain variables and diagnostic properties. In a transverse retrospective age-adjusted case-control study, 221 subjects with sinus rhythm without bundle branch block were divided into three groups after signal-averaged ECG acquisition: GI (N = 40, clinically normal controls, GII (N = 158, subjects with coronary heart disease without sustained monomorphic ventricular tachycardia (SMVT, and GIII (N = 23, subjects with heart disease and documented SMVT. Conventional variables analyzed from vector magnitude data after averaging to 0.3 µV final noise were obtained by application of each filter to the averaged signal, and evaluated in pairs by numerical comparison and by diagnostic agreement assessment, using conventional and optimized thresholds of normality. Significant differences were found between BI and BD variables in all groups, with diagnostic results showing significant disagreement between both filters [kappa value of 0.61 (P<0.05 for GII and 0.31 for GIII (P = NS]. Sensitivity for SMVT was lower with BI than with BD (65.2 vs 91.3%, respectively, P<0.05. Filters provided significantly different numerical and diagnostic results and the BI filter showed only limited clinical application to risk stratification of ventricular arrhythmia.

  18. Minimally Invasive Implantation of HeartWare Assist Device and Simultaneous Tricuspid Valve Reconstruction Through Partial Upper Sternotomy.

    Science.gov (United States)

    Hillebrand, Julia; Hoffmeier, Andreas; Djie Tiong Tjan, Tonny; Sindermann, Juergen R; Schmidt, Christoph; Martens, Sven; Scherer, Mirela

    2017-05-01

    Left ventricular assist device (LVAD) implantation is a well-established therapy to support patients with end-stage heart failure. However, the operative procedure is associated with severe trauma. Third generation LVADs like the HeartWare assist device (HeartWare, Inc., Framingham, MA, USA) are characterized by enhanced technology despite smaller size. These devices offer new minimally invasive surgical options. Tricuspid regurgitation requiring valve repair is frequent in patients with the need for mechanical circulatory support as it is strongly associated with ischemic and nonischemic cardiomyopathy. We report on HeartWare LVAD implantation and simultaneous tricuspid valve reconstruction through minimally invasive access by partial upper sternotomy to the fifth left intercostal space. Four male patients (mean age 51.72 ± 11.95 years) suffering from chronic heart failure due to dilative (three patients) and ischemic (one patient) cardiomyopathy and also exhibiting concomitant tricuspid valve insufficiency due to annular dilation underwent VAD implantation and tricuspid valve annuloplasty. Extracorporeal circulation was established via the ascending aorta, superior vena cava, and right atrium. In all four cases the LVAD implantation and tricuspid valve repair via partial median sternotomy was successful. During the operative procedure, no conversion to full sternotomy was necessary. One patient needed postoperative re-exploration because of pericardial effusion. No postoperative focal neurologic injury was observed. New generation VADs are advantageous because of the possibility of minimally invasive implantation procedure which can therefore minimize surgical trauma. Concomitant tricuspid valve reconstruction can also be performed simultaneously through partial upper sternotomy. Nevertheless, minimally invasive LVAD implantation is a challenging operative technique. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals

  19. Development and evaluation of totally implantable ventricular assist system using a vibrating flow pump and transcutaneous energy transmission system with amorphous fibers.

    Science.gov (United States)

    Yambe, T; Hashimoto, H; Kobayashi, S; Sonobe, T; Naganuma, S; Nanka, S S; Matsuki, H; Yoshizawa, M; Tabayashi, K; Takayasu, H; Takeda, H; Nitta, S

    1997-01-01

    We have developed a vibrating flow pump (VFP) that can generate oscillated blood flow with a relatively high frequency (10-50 Hz) for a totally implantable ventricular assist system (VAS). To evaluate the newly developed VAS, left heart bypasses, using the VFP, were performed in chronic animal experiments. Hemodynamic parameters were recorded in a data recorder in healthy adult goats during an awake condition and analyzed in a personal computer system through an alternating-direct current converter. Basic performance of the total system with a transcutaneous energy transmission system were satisfactory. During left ventricular assistance with the VFP, Mayer wave fluctuations of hemodynamics were decreased in the power spectrum, the fractal dimensions of the hemodynamics were significantly decreased, and peripheral vascular resistance was significantly decreased. These results suggest that cardiovascular regulatory nonlinear dynamics, which mediate the hemodynamics, may be affected by left ventricular bypass with oscillated flow. The decreased power of the Mayer wave in the spectrum caused the limit cycle attractor of the hemodynamics and decreased peripheral resistance. These results suggest that this newly developed VAS is useful for the totally implantable system with unique characteristics that can control hemodynamic properties.

  20. Internet-Based Device-Assisted Remote Monitoring of Cardiovascular Implantable Electronic Devices

    Science.gov (United States)

    Pron, G; Ieraci, L; Kaulback, K

    2012-01-01

    Executive Summary Objective The objective of this Medical Advisory Secretariat (MAS) report was to conduct a systematic review of the available published evidence on the safety, effectiveness, and cost-effectiveness of Internet-based device-assisted remote monitoring systems (RMSs) for therapeutic cardiac implantable electronic devices (CIEDs) such as pacemakers (PMs), implantable cardioverter-defibrillators (ICDs), and cardiac resynchronization therapy (CRT) devices. The MAS evidence-based review was performed to support public financing decisions. Clinical Need: Condition and Target Population Sudden cardiac death (SCD) is a major cause of fatalities in developed countries. In the United States almost half a million people die of SCD annually, resulting in more deaths than stroke, lung cancer, breast cancer, and AIDS combined. In Canada each year more than 40,000 people die from a cardiovascular related cause; approximately half of these deaths are attributable to SCD. Most cases of SCD occur in the general population typically in those without a known history of heart disease. Most SCDs are caused by cardiac arrhythmia, an abnormal heart rhythm caused by malfunctions of the heart’s electrical system. Up to half of patients with significant heart failure (HF) also have advanced conduction abnormalities. Cardiac arrhythmias are managed by a variety of drugs, ablative procedures, and therapeutic CIEDs. The range of CIEDs includes pacemakers (PMs), implantable cardioverter-defibrillators (ICDs), and cardiac resynchronization therapy (CRT) devices. Bradycardia is the main indication for PMs and individuals at high risk for SCD are often treated by ICDs. Heart failure (HF) is also a significant health problem and is the most frequent cause of hospitalization in those over 65 years of age. Patients with moderate to severe HF may also have cardiac arrhythmias, although the cause may be related more to heart pump or haemodynamic failure. The presence of HF, however

  1. 78 FR 34922 - Definition of Auditory Assistance Device

    Science.gov (United States)

    2013-06-11

    ... permitting such use of these devices would increase the comprehension of persons that need language... communications (including but not limited to applications such as assistive listening, auricular training, audio...

  2. Microwave-assisted in situ synthesis of reduced graphene oxide-BiVO4 composite photocatalysts and their enhanced photocatalytic performance for the degradation of ciprofloxacin.

    Science.gov (United States)

    Yan, Yan; Sun, Shaofang; Song, Yang; Yan, Xu; Guan, Weisheng; Liu, Xinlin; Shi, Weidong

    2013-04-15

    To improve the photodegradation efficiency for ciprofloxacin (CIP), a new-type microwave-assisted in situ growth method is developed for the preparation of reduced graphene oxide (RGO) -BiVO4 composite photocatalysts. The as-produced RGO-BiVO4 composite photocatalysts show extremely high enhancement of CIP degradation ratio over the pure BiVO4 photocatalyst under visible light. Specially, the 2 wt% RGO-BiVO4 composite photocatalyst exhibits the highest CIP degradation ratio (68.2%) in 60 min, which is over 3 times than that (22.7%) of the pure BiVO4 particles. The enhancement of photocatalytic activities of RGO-BiVO4 photocatalysts can be attributed to the effective separation of electron-hole pairs rather than the improvement of light absorption. Copyright © 2013 Elsevier B.V. All rights reserved.

  3. Assistive acting movement therapy devices with pneumatic rotary-type soft actuators.

    Science.gov (United States)

    Wilkening, André; Baiden, David; Ivlev, Oleg

    2012-12-01

    Inherent compliance and assistive behavior are assumed to be essential properties for safe human-robot interaction. Rehabilitation robots demand the highest standards in this respect because the machine interacts directly with weak persons who are often sensitive to pain. Using novel soft fluidic actuators with rotary elastic chambers (REC actuators), compact, lightweight, and cost-effective therapeutic devices can be developed. This article describes modular design and control strategies for new assistive acting robotic devices for upper and lower extremities. Due to the inherent compliance and natural back-drivability of pneumatic REC actuators, these movement therapy devices provide gentle treatment, whereby the interaction forces between humans and the therapy device are estimated without the use of expensive force/torque sensors. An active model-based gravity compensation based on separated models of the robot and of the individual patient's extremity provides the basis for effective assistive control. The utilization of pneumatic actuators demands a special safety concept, which is merged with control algorithms to provide a sufficient level of safeness and to catch any possible system errors and/or emergency situations. A self-explanatory user interface allows for easy, intuitive handling. Prototypes are very comfortable for use due to several control routines that work in the background. Assistive devices have been tested extensively with several healthy persons; the knee/hip movement therapy device is now under clinical trials at the Clinic for Orthopaedics and Trauma Surgery at the Klinikum Stuttgart.

  4. Synthesis of BiFeO3 thin films on single-terminated Nb : SrTiO3 (111 substrates by intermittent microwave assisted hydrothermal method

    Directory of Open Access Journals (Sweden)

    Ivan Velasco-Davalos

    2016-06-01

    Full Text Available We report on a simple and fast procedure to create arrays of atomically flat terraces on single crystal SrTiO3 (111 substrates and the deposition of ferroelectric BiFeO3 thin films on such single-terminated surfaces. A microwave-assisted hydrothermal method in deionized water and ammonia solution selectively removes either (SrO34− or Ti4+ layers to ensure the same chemical termination on all terraces. Measured step heights of 0.225 nm (d111 and uniform contrast in the phase image of the terraces confirm the single termination in pure and Nb doped SrTiO3 single crystal substrates. Multiferroic BiFeO3 thin films were then deposited by the same microwave assisted hydrothermal process on Nb : SrTiO3 (111 substrates. Bi(NO33 and Fe(NO33 along with KOH served as the precursors solution. Ferroelectric behavior of the BiFeO3 films on Nb : SrTiO3 (100 substrates was verified by piezoresponse force microscopy.

  5. Flecainide attenuates rate adaptation of ventricular repolarization in guinea-pig heart

    DEFF Research Database (Denmark)

    Osadchii, Oleg E.

    2016-01-01

    examined flecainide effect on adaptation of the QT interval and ventricular action potential duration (APD) to abrupt reductions of the cardiac cycle length. DESIGN: ECG and ventricular epicardial and endocardial monophasic APD were recorded in isolated, perfused guinea-pig heart preparations upon...... a sustained cardiac acceleration (rapid pacing for 30 s), and following a single perturbation of the cycle length evoked by extrasystolic stimulation. RESULTS: Sustained increase in heart rate was associated with progressive bi-exponential shortening of the QT interval and APD. Flecainide prolonged...

  6. Effect of right ventricular electrode location (outflow tract vs. apex) on mechanical Ventricular synchrony in patients that underwent pacemaker implant therapy

    International Nuclear Information System (INIS)

    Rincon, Oscar S; Saenz, Luis C; Salazar, Gabriel; Hernandez, Edgar

    2008-01-01

    Objective: to assess in depth the effect of ventricular stimulation from the right ventricular outflow tract and the apex on mechanical ventricular synchrony. Materials And Methods: cohort analytical study. 20 patients with indication of definitive pacemaker indication underwent trans thoracic echocardiogram before and after pacemaker implant with electrode implantation in the right ventricular outflow tract and in the apex (10 patients in each group). There was no structural cardiopathy, ejection fraction was ? 50%, QRS and AV conduction were normal. Mechanical ventricular asynchrony (M mode and tissue doppler) and implant and device parameters were evaluated. Statistical Analysis: results are given as mean values, standard deviation or percentages.Continuous variables were compared using Chi-square test and ANOVA. A p <0.05 value was considered statistically significant. Results: in five patients (25%) a pre-implant ventricular asynchrony was found; in seven (70%) ventricular asynchrony post-implant in the right ventricle outflow tract and in 5 (50%) in the apex. Mean interventricular pot-implant delay was 21,6 ms in the right ventricular outflow tract and 11,5 ms in the apex (p = 0,8); mean septal to lateral wall delay was 73 ms in the right ventricular outflow tract and 26 ms in the apex (p = 0,8). QRS post-implant delay was 134 ms in the right ventricular outflow tract and 140 ms in the apex (p = 0,1). No differences between implant parameters and device programming were found. Conclusions: presence of ventricular asynchrony was evidenced in patients with normal QRS and structurally healthy heart. Ventricular stimulation with pacemaker from the apex or the right ventricular outflow tract suggests acute ventricular asynchrony at least in 60% of the cases, without statistically significant difference between both groups.

  7. Left ventricular function and visual phase analysis with equilibrium radionuclide angiography in patients with biventricular device

    International Nuclear Information System (INIS)

    Muxi, Africa; Setoain, Francisco J.; Pons, Francisca; Paredes, Pilar; Duch, Joan; Fuertes, Silvia; Ortin, Jaime; Mont, Lluis; Diaz-Infante, Ernesto

    2008-01-01

    Cardiac resynchronisation therapy (CRT) is a technique indicated in patients with moderate to severe heart failure and ventricular dyssynchrony. To evaluate left ventricular ejection fraction (LVEF) and synchronisation changes after CRT with a biventricular pacing implant, we used an equilibrium radionuclide angiography (ERNA). Fifty patients were studied. An ERNA was made 72 h and 6 months after the implant. Two acquisitions were performed: with the CRT device connected and after disconnecting it. In the follow-up, responders were defined as those who had improved in accordance with various clinical variables. Quantitative changes in LVEF and visual changes in synchronisation (phase analysis) were studied comparing the two studies and also comparing the connected and disconnected modes. At 6 months, 30 patients were defined as responders. LVEF increased significantly at 6 months compared with the 72-h study only in responders. At 72 h, the number of patients showing a decrease in LVEF (p < 0.05) or a synchronisation worsening after disconnecting the device was higher in responders than in nonresponders. At 6 months, 57% of responders had no synchronisation changes between the connected and disconnected modes, suggesting a resynchronisation process. ERNA permits the study of resynchronisation patients, showing a statistical LVEF improvement at 6 months. Moreover, visual phase analysis permits the study of the mechanism involved in the response, with an important number of responders with no changes between the two modes at 6 months. In the 72-h study, after disconnection of the device, LVEF and resynchronisation worsening can predict patient improvement at 6 months. (orig.)

  8. Levosimendan in Patients with Left Ventricular Dysfunction Undergoing Cardiac Surgery.

    Science.gov (United States)

    Mehta, Rajendra H; Leimberger, Jeffrey D; van Diepen, Sean; Meza, James; Wang, Alice; Jankowich, Rachael; Harrison, Robert W; Hay, Douglas; Fremes, Stephen; Duncan, Andra; Soltesz, Edward G; Luber, John; Park, Soon; Argenziano, Michael; Murphy, Edward; Marcel, Randy; Kalavrouziotis, Dimitri; Nagpal, Dave; Bozinovski, John; Toller, Wolfgang; Heringlake, Matthias; Goodman, Shaun G; Levy, Jerrold H; Harrington, Robert A; Anstrom, Kevin J; Alexander, John H

    2017-05-25

    Levosimendan is an inotropic agent that has been shown in small studies to prevent or treat the low cardiac output syndrome after cardiac surgery. In a multicenter, randomized, placebo-controlled, phase 3 trial, we evaluated the efficacy and safety of levosimendan in patients with a left ventricular ejection fraction of 35% or less who were undergoing cardiac surgery with the use of cardiopulmonary bypass. Patients were randomly assigned to receive either intravenous levosimendan (at a dose of 0.2 μg per kilogram of body weight per minute for 1 hour, followed by a dose of 0.1 μg per kilogram per minute for 23 hours) or placebo, with the infusion started before surgery. The two primary end points were a four-component composite of death through day 30, renal-replacement therapy through day 30, perioperative myocardial infarction through day 5, or use of a mechanical cardiac assist device through day 5; and a two-component composite of death through day 30 or use of a mechanical cardiac assist device through day 5. A total of 882 patients underwent randomization, 849 of whom received levosimendan or placebo and were included in the modified intention-to-treat population. The four-component primary end point occurred in 105 of 428 patients (24.5%) assigned to receive levosimendan and in 103 of 421 (24.5%) assigned to receive placebo (adjusted odds ratio, 1.00; 99% confidence interval [CI], 0.66 to 1.54; P=0.98). The two-component primary end point occurred in 56 patients (13.1%) assigned to receive levosimendan and in 48 (11.4%) assigned to receive placebo (adjusted odds ratio, 1.18; 96% CI, 0.76 to 1.82; P=0.45). The rate of adverse events did not differ significantly between the two groups. Prophylactic levosimendan did not result in a rate of the short-term composite end point of death, renal-replacement therapy, perioperative myocardial infarction, or use of a mechanical cardiac assist device that was lower than the rate with placebo among patients with a

  9. A novel ventricular restraint device (ASD) repetitively deliver Salvia miltiorrhiza to epicardium have good curative effects in heart failure management.

    Science.gov (United States)

    Naveed, Muhammad; Wenhua, Li; Gang, Wang; Mohammad, Imran Shair; Abbas, Muhammad; Liao, Xiaoqian; Yang, Mengqi; Zhang, Li; Liu, Xiaolin; Qi, Xiaoming; Chen, Yineng; Jiadi, Lv; Ye, Linlan; Zhijie, Wang; Ding, Chen Ding; Feng, Yu; Xiaohui, Zhou

    2017-11-01

    A novel ventricular restraint is the non-transplant surgical option for the management of an end-stage dilated heart failure (HF). To expand the therapeutic techniques we design a novel ventricular restraint device (ASD) which has the ability to deliver a therapeutic drug directly to the heart. We deliver a Traditional Chinese Medicine (TCM) Salvia miltiorrhiza (Danshen Zhusheye) through active hydraulic ventricular support drug delivery system (ASD) and we hypothesize that it will show better results in HF management than the restraint device and drug alone. SD rats were selected and divided into five groups (n=6), Normal, HF, HF+SM (IV), HF+ASD, HF+ASD+SM groups respectively. Post myocardial infarction (MI), electrocardiography (ECG) showed abnormal heart function in all groups and HF+ASD+SM group showed a significant therapeutic improvement with respect to other treatment HF, HF+ASD, and HF+SM (IV) groups on day 30. The mechanical functions of the heart such as heart rate, LVEDP, and LVSP were brought to normal when treated with ASD+SM and show significant (P valueASD+SM group animals compared with other treatment groups. Masson's Trichrome staining was used to study histopathology of cardiac myocytes and quantification of fibrosis was assessed. The large blue fibrotic area was observed in HF, HF+ASD, and HF+SM (IV) groups while HF+ASD+SM showed negligible fibrotic myocyte at the end of study period (30days). This study proves that novel ASD device augments the therapeutic effect of the drug and delivers Salvia miltiorrhiza to the cardiomyocytes significantly as well as provides additional support to the dilated ventricle by the heart failure. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  10. Bi-stable optical actuator

    Science.gov (United States)

    Holdener, Fred R.; Boyd, Robert D.

    2000-01-01

    The present invention is a bi-stable optical actuator device that is depowered in both stable positions. A bearing is used to transfer motion and smoothly transition from one state to another. The optical actuator device may be maintained in a stable position either by gravity or a restraining device.

  11. Experience of a patient with an extracorporeal ventricular assist system who participated in a sleepover program.

    Science.gov (United States)

    Gon, Shigeyoshi; Suematsu, Yoshihito; Morizumi, Sei; Shimizu, Tsuyoshi

    2011-09-01

    A 19-year-old woman suffered fulminant myocarditis owing to a mycoplasma infection and was inserted with an intra-aortic balloon pump and a percutaneous cardiopulmonary support. Antibiotics and gamma globulin were administered, however, the patient's cardiac function did not recover, and the TOYOBO ventricular assist device (VAD) was implanted. She had rehabilitation training such as maintaining a standing position at the bedside and walking in the hospital, and a hospital outing program to a family restaurant was conducted two times with the VAD. The patient wished to attend the coming-of-age ceremony in Tachikawa city, which is 3 h away from our hospital by car. Therefore, we planned the program including a night stay at her home. The patient and her family fully understood the risks and wished to participate in the sleepover program. In preparing for the sleepover, the patient and her family learned to operate the VAD, and she was able to move to the lavatory and through the house with the help of only her family. A physician and a clinical engineer stayed at her house for infusion of antibiotics and management of sudden changes. There was no adverse event. In Japan, the community support of patients with VAD is not yet established, and we hope that our experience becomes a help to support return to society for patients with VAD.

  12. One-step growth of nanosheet-assembled BiOCl/BiOBr microspheres for highly efficient visible photocatalytic performance

    Science.gov (United States)

    Zhang, Jinfeng; Lv, Jiali; Dai, Kai; Liang, Changhao; Liu, Qi

    2018-02-01

    In this work, we have developed a simple synthetic approach of nanosheet-assembled BiOCl/BiOBr microspheres by an ethylene glycol (EG)-assisted hydrothermal method. The crystalline form, morphology, chemical composition, optical performance and surface area of BiOCl/BiOBr microspheres were identified using X-ray diffraction (XRD), transmission electron microscopy (TEM), high resolution TEM (HRTEM), scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy spectra (EDX), UV-vis diffuse reflectance spectroscopy (DRS) analysis, high resolution X-ray photoelectron spectra (XPS) and N2 adsorption-desorption isotherms. BiOCl/BiOBr microspheres were nanosheet-assembled particles, which possessed visible light absorption under LED light irridation. Additionally, the methylene blue (MB) photodegradation performance of different BiOCl/BiOBr microspheres irradiated under 410 nm LED light arrays were investigated, the results exhibited that as-prepared BiOCl/BiOBr products showed higher catalytic effiency than pure BiOCl or BiOBr. By optimizing the composition ration of the BiOCl and BiOBr, up to 93% degradation rate can be obtained in the 40%BiOCl/BiOBr microspheres. Finally, the photocatalytic mechanism of BiOCl/BiOBr microspheres had been proposed.

  13. Transthoracic device closure of ventricular septal defects without cardiopulmonary bypass: experience in infants weighting less than 8 kg.

    Science.gov (United States)

    Xing, Quansheng; Wu, Qin; Pan, Silin; Ren, Yueyi; Wan, Hao

    2011-09-01

    Both surgical and percutaneous device closure of ventricular septal defect (VSD) have drawbacks and limitations in infants. We report our experiences and midterm results of transthoracic device closure of VSDs (TDCVs) without cardiopulmonary bypass (CPB) in infants. Between September 2007 and September 2009, 32 patients, with a mean age of 7.2 ± 4.7 months, body weight of 6.8 ± 2.8 kg, underwent this procedure. The procedure was performed in the operating room. A small subxiphoid incision was made. A purse-string suture was placed on the right ventricular free wall. The free wall was punctured using a trocar, then a guide wire was inserted and advanced to cross the VSD into the left ventricle under transesophageal echocardiographic guidance. A modified delivery sheath was then introduced over the guide wire. The device was delivered and deployed in position along the sheath to close the defect. A total of 30 cases (94%) were successfully closed, and the remaining two cases (6%) were converted to open heart repair. No patients received transfusion. There was no perioperative mortality, or any major complication. The mean size of the devices was 7.6 ± 3.4mm. The total operative time was less than 60 min, and the mean time for device implantation was 18.3 ± 9.4 min. All patients were extubated within 2h, and were discharged within 5 days after operation. The follow-up period ranged from 6 to 31 months (18.3 ± 9.6 months). There was no late major complication detected. Minimally invasive TDCV without CPB is a safe and effective alternative to the conventional operation in low-body-weight infants. Copyright © 2010 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.

  14. The Impact of Ventricular Assist Device Prior to Transplantation on Morphological Parameters in Cardiac Allografts

    DEFF Research Database (Denmark)

    Wassilew, Katharina

    2017-01-01

    . The Cochran-Mantel-Haenzsel test was applied to assess significance of the differences in interactions between groups. To evaluate the impact of bridge- to- transplant mechanical circulatory support on development on transplant vasculopathy in cardiac allografts, the intramyocardial terminal arterial network...... allograft dysfunction, as MCS patients show a higher frequency of antibody-mediated rejection (AMR) episodes. We aimed to analyze the effects of MCS on cardiac AMR with regards to capillary C3d and C4d depositions. Regarding the functional parameters, both acute cellular rejection (ACR) and an increase...... of interstitial fibrosis (IF) often correlate with impaired ventricular function. The innate immune system, in particular macrophages, plays an important role in the resorptive process of ACR and is, on the other hand, known to promote IF. In this study we aimed to analyze the effect of ACR and specifically...

  15. Assistive device use and mobility-related factors among adults aged≥65years.

    Science.gov (United States)

    West, Bethany A; Bhat, Geeta; Stevens, Judy; Bergen, Gwen

    2015-12-01

    Examining how assistive device (cane, walker) use relates to other mobility factors can provide insight into older adults' future mobility needs. Data come from the Second Injury Control and Risk Survey, Phase 2 (ICARIS2-P2), conducted from March 2007 to May 2008. Prevalence estimates were calculated for older adults (aged ≥65) and multivariable logistic regression was used to explore associations between assistive device use and mobility-related characteristics. Compared with non-users, assistive device users were more likely to report a recent fall (AOR 12.0; 95% CI 4.9-29.3), limit walking outside due to concerns about falling (AOR 7.1; 95% CI 2.6-19.1), be unable to walk outside for 10min without resting (AOR 3.3; 95% CI 1.1-9.3), and be no longer driving (AOR 6.7; 95% CI 2.0-22.3). Assistive device users have limited mobility and an increased risk for fall injury compared with non-users. Effective fall prevention interventions, and innovative transportation options, are needed to protect the mobility of this high-risk group. Published by Elsevier Ltd.

  16. A bi-ventricular cardiac atlas built from 1000+ high resolution MR images of healthy subjects and an analysis of shape and motion.

    Science.gov (United States)

    Bai, Wenjia; Shi, Wenzhe; de Marvao, Antonio; Dawes, Timothy J W; O'Regan, Declan P; Cook, Stuart A; Rueckert, Daniel

    2015-12-01

    Atlases encode valuable anatomical and functional information from a population. In this work, a bi-ventricular cardiac atlas was built from a unique data set, which consists of high resolution cardiac MR images of 1000+ normal subjects. Based on the atlas, statistical methods were used to study the variation of cardiac shapes and the distribution of cardiac motion across the spatio-temporal domain. We have shown how statistical parametric mapping (SPM) can be combined with a general linear model to study the impact of gender and age on regional myocardial wall thickness. Finally, we have also investigated the influence of the population size on atlas construction and atlas-based analysis. The high resolution atlas, the statistical models and the SPM method will benefit more studies on cardiac anatomy and function analysis in the future. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Wireless patient monitoring system for a moving-actuator type artificial heart.

    Science.gov (United States)

    Nam, K W; Chung, J; Choi, S W; Sun, K; Min, B G

    2006-10-01

    In this study, we developed a wireless monitoring system for outpatients equipped with a moving-actuator type pulsatile bi-ventricular assist device, AnyHeart. The developed monitoring system consists of two parts; a Bluetooth-based short-distance self-monitoring system that can monitor and control the operating status of a VAD using a Bluetooth-embedded personal digital assistant or a personal computer within a distance of 10 meters, and a cellular network-based remote monitoring system that can continuously monitor and control the operating status of AnyHeart at any location. Results of in vitro experiments demonstrate the developed system's ability to monitor the operational status of an implanted AnyHeart.

  18. Left ventricular epicardial activation increases transmural dispersion of repolarization in healthy, long QT, and dilated cardiomyopathy dogs.

    Science.gov (United States)

    Bai, Rong; Lü, Jiagao; Pu, Jun; Liu, Nian; Zhou, Qiang; Ruan, Yanfei; Niu, Huiyan; Zhang, Cuntai; Wang, Lin; Kam, Ruth

    2005-10-01

    Benefits of cardiac resynchronization therapy (CRT) are well established. However, less is understood concerning its effects on myocardial repolarization and the potential proarrhythmic risk. Healthy dogs (n = 8) were compared to a long QT interval (LQT) model (n = 8, induced by cesium chloride, CsCl) and a dilated cardiomyopathy with congestive heart failure (DCM-CHF, induced by rapid ventricular pacing, n = 5). Monophasic action potential (MAP) recordings were obtained from the subendocardium, midmyocardium, subepicardium, and the transmural dispersion of repolarization (TDR) was calculated. The QT interval and the interval from the peak to the end of the T wave (T(p-e)) were measured. All these characteristics were compared during left ventricular epicardial (LV-Epi), right ventricular endocardial (RV-Endo), and biventricular (Bi-V) pacing. In healthy dogs, TDR prolonged to 37.54 ms for Bi-V pacing and to 47.16 ms for LV-Epi pacing as compared to 26.75 ms for RV-Endo pacing (P canine models in addition to their intrinsic transmural heterogeneity in the intact heart. This mechanism may contribute to the development of malignant ventricular arrhythmias, such as torsades de pointes (TdP) in congestive heart failure (CHF) patients treated with CRT.

  19. Development of Hand Grip Assistive Device Control System for Old People through Electromyography (EMG) Signal Acquisitions

    OpenAIRE

    Khamis Herman; Mohamaddan Shahrol; Komeda Takashi; Alias Aidil Azli; Tanjong Shirley Jonathan; Julai Norhuzaimin; Hashim Nurul ‘Izzati

    2017-01-01

    The hand grip assistive device is a glove to assist old people who suffer from hand weakness in their daily life activities. The device earlier control system only use simple on and off switch. This required old people to use both hand to activate the device. The new control system of the hand grip assistive device was developed to allow single hand operation for old people. New control system take advantages of electromyography (EMG) and flex sensor which was implemented to the device. It wa...

  20. Monitoring ventricular function at rest and during exercise with a nonimaging nuclear detector

    International Nuclear Information System (INIS)

    Wagner, H.N. Jr.; Rigo, P.; Baxter, R.H.; Alderson, P.O.; Douglass, K.H.; Housholder, D.F.

    1979-01-01

    A portable nonimaging device, the nuclear stethoscope, for measuring beat to beat ventricular time-activity curves in normal people and patients with heart disease, both at rest and during exercise, is being developed and evaluated. The latest device has several operting modes that facilitate left ventricular and background localization, measurement of transit times and automatic calculation and display of left ventricular ejection fraction. The correlation coefficient of left ventricular ejection fraction obtained with the device and with a camera-computer system was 0.92 in 35 subjects. During bicycle exercise the ejection fraction in 15 normal persons increased from 44 to 64% (P less than 0.001), whereas among 12 patients with heart disease it was unchanged in 5 and decreased in 7

  1. Monitoring ventricular function at rest and during exercise with a nonimaging nuclear detector.

    Science.gov (United States)

    Wagner, H N; Rigo, P; Baxter, R H; Alderson, P O; Douglass, K H; Housholder, D F

    1979-05-01

    A portable nonimaging device, the nuclear stethoscope, for measuring beat to beat ventricular time-activity curves in normal people and patients with heart disease, both at rest and during exercise, is being developed and evaluated. The latest device has several operating modes that facilitate left ventricular and background localization, measurement of transit times and automatic calculation and display of left ventricular ejection fraction. The correlation coefficient of left ventricular ejection fraction obtained with the device and with a camera-computer system was 0.92 in 35 subjects. During bicycle exercise the ejection fraction in 15 normal persons increased from 44 to 64 percent (P less than 0.001), whereas among 12 patients with heart disease it was unchanged in 5 and decreased in 7.

  2. Evaluation of a novel ventricular support device with defibrillation capabilities in canine and porcine animal models.

    Science.gov (United States)

    Killingsworth, Cheryl R; Rippy, Marian K; Virmani, Renu; Rollins, Dennis L; McGiffin, David C; Ideker, Raymond E

    2008-08-01

    Sudden death is prevalent in heart failure patients. We tested an implantable ventricular support device consisting of a wireform harness with one or two pairs of integrated defibrillation electrode coils. The device was implanted into six pigs (36-44 kg) through a subxiphoid incision. Peak voltage (V) defibrillation thresholds (DFT) were determined for five test configurations compared with a control transvenous lead (RV to CanPect). Defibrillator can location (abdominal or pectoral) and common coil separation on the implant (0 degrees or 60 degrees ) were studied.(.) The DFT for RV60 to LV60 + CanPect was significantly less than control (348 +/- 57 vs 473 +/- 27 V, P < 0.05). The DFTs for other vectors were similar to control except for RV0 to LV0 + CanAbd (608 +/- 159 V). The device was implanted into 12 adult dogs for 42, 90, or 180 days with DFT and pathological examination performed at the terminal study. Cardiac pressures were determined at baseline, after implantation, and at the terminal study. The DFT was also determined in a separate group of four dogs at 42 days following implantation of the support device with one pair of defibrillation electrodes. The DFTs at implant and explant in dogs with one pair (8 +/- 1.5 Joules [J] and 6 +/- 1.9 J) or two pairs (8 +/- 3.4 J and 7 +/- 1.9 J) of defibrillation electrodes were not significantly different from each other but significantly less than control measured at the terminal study (18 +/- 3.4 J). Left-sided pressures were significantly decreased at explant but within expected normal ranges. Right-sided pressures were not different except for RV systolic. Histopathology indicated mild to moderate epicardial inflammation and fibrosis, consistent with a foreign body healing response. This defibrillation-enabled ventricular support system maintained mechanical functionality for up to 6 months while inducing typical chronic healing responses. The DFT was equal to or lower than a standard transvenous vector.

  3. Physiological control of dual rotary pumps as a biventricular assist device using a master/slave approach.

    Science.gov (United States)

    Stevens, Michael C; Wilson, Stephen; Bradley, Andrew; Fraser, John; Timms, Daniel

    2014-09-01

    Dual rotary left ventricular assist devices (LVADs) can provide biventricular mechanical support during heart failure. Coordination of left and right pump speeds is critical not only to avoid ventricular suction and to match cardiac output with demand, but also to ensure balanced systemic and pulmonary circulatory volumes. Physiological control systems for dual LVADs must meet these objectives across a variety of clinical scenarios by automatically adjusting left and right pump speeds to avoid catastrophic physiological consequences. In this study we evaluate a novel master/slave physiological control system for dual LVADs. The master controller is a Starling-like controller, which sets flow rate as a function of end-diastolic ventricular pressure (EDP). The slave controller then maintains a linear relationship between right and left EDPs. Both left/right and right/left master/slave combinations were evaluated by subjecting them to four clinical scenarios (rest, postural change, Valsalva maneuver, and exercise) simulated in a mock circulation loop. The controller's performance was compared to constant-rotational-speed control and two other dual LVAD control systems: dual constant inlet pressure and dual Frank-Starling control. The results showed that the master/slave physiological control system produced fewer suction events than constant-speed control (6 vs. 62 over a 7-min period). Left/right master/slave control had lower risk of pulmonary congestion than the other control systems, as indicated by lower maximum EDPs (15.1 vs. 25.2-28.4 mm Hg). During exercise, master/slave control increased total flow from 5.2 to 10.1 L/min, primarily due to an increase of left and right pump speed. Use of the left pump as the master resulted in fewer suction events and lower EDPs than when the right pump was master. Based on these results, master/slave control using the left pump as the master automatically adjusts pump speed to avoid suction and increases pump flow

  4. Network-Assisted Device-to-Device (D2D) Direct Proximity Discovery with Underlay Communication

    DEFF Research Database (Denmark)

    Pratas, Nuno; Popovski, Petar

    2015-01-01

    ) direct communication between proximate devices. While (ii) is treated extensively in the recent literature, (i) has received relatively little attention. In this paper we analyze a network-assisted underlay proximity discovery protocol, where a cellular device can take the role of: announcer (which......Device-to-Device communications are expected to play an important role in current and future cellular generations, by increasing the spatial reuse of spectrum resources and enabling lower latency communication links. This paradigm has two fundamental building blocks: (i) proximity discovery and (ii......, we consider the case where the announcers underlay their messages in the downlink transmissions that are directed towards the monitoring devices. We propose a power control scheme applied to the downlink transmission, which copes with the underlay transmission via additional power expenditure, while...

  5. The SiBI connector: a new medical device to facilitate preoxygenation and reduce waste anesthetic gases during inhaled induction with sevoflurane.

    Science.gov (United States)

    Colas, M J; Tétrault, J P; Dumais, L; Truong, P; Claprood, Y; Martin, R

    2000-12-01

    The SiBI connector is a new medical device used for vital capacity inhaled induction with sevoflurane. It allows efficient preoxygenation of patients and reduces waste anesthetic gases in the operation room during induction.

  6. Heartmate 3 fully magnetically levitated left ventricular assist device for the treatment of advanced heart failure -1 year results from the Ce mark trial.

    Science.gov (United States)

    Krabatsch, Thomas; Netuka, Ivan; Schmitto, Jan D; Zimpfer, Daniel; Garbade, Jens; Rao, Vivek; Morshuis, Michiel; Beyersdorf, Friedhelm; Marasco, Silvana; Damme, Laura; Pya, Yuriy

    2017-04-04

    The HeartMate 3 Left Ventricular Assist System (LVAS) (St. Jude Medical Inc., St Paul, MN) with full magnetic levitation allows for wide and consistent blood flow paths and an artificial pulse designed for enhanced hemocompatibility. The HeartMate 3 received market approval in the European Union in 2015 following completion of a multicenter study. After reaching the 6-month study endpoint, patients continue to be followed for 2 years with the 1-year results presented herein. A prospective, non-randomized study included adults with advanced heart failure and ejection fraction (EF) ≤ 25%, cardiac index (CI) ≤ 2.2 L/min/m2 while not on inotropes, or inotrope dependent, or on optimal medical management for 45/60 days. Fifty patients-54% bridge to transplant (BTT) and 46% destination therapy (DT)-were enrolled and implanted with the HeartMate 3. At baseline, 92% of the patients were INTERMACS profiles 2-4, with cardiac index 1.8 + 0.5 L/min/m 2 and 58% were supported with inotropes. At 1 year, 74% of the patients remain on support, 18% expired, 6% transplanted, and 2% explanted. The adverse events include 12% gastrointestinal bleeding, 16% driveline infections, 18% strokes, and 2% outflow graft thrombosis. There was no hemolysis, pump thrombosis or pump malfunction through 1 year. The six-minute walk test distance increased from a mean of 273 m to 371 m (P <0.0001). EQ-5D quality-of-life score increased from a mean of 52.7 to 70.8 (P = 0.0006). The 1-year HeartMate 3 LVAS results show survival and adverse-event profile are similar to other approved devices, with no pump thrombosis or pump failure. Patient's functional status and quality of life significantly improved over time. Clinicaltrials.gov registration number: NCT02170363 . Registered June 19, 2014.

  7. Superstrengthening Bi2Te3 through Nanotwinning

    Science.gov (United States)

    Li, Guodong; Aydemir, Umut; Morozov, Sergey I.; Wood, Max; An, Qi; Zhai, Pengcheng; Zhang, Qingjie; Goddard, William A.; Snyder, G. Jeffrey

    2017-08-01

    Bismuth telluride (Bi2Te3 ) based thermoelectric (TE) materials have been commercialized successfully as solid-state power generators, but their low mechanical strength suggests that these materials may not be reliable for long-term use in TE devices. Here we use density functional theory to show that the ideal shear strength of Bi2Te3 can be significantly enhanced up to 215% by imposing nanoscale twins. We reveal that the origin of the low strength in single crystalline Bi2Te3 is the weak van der Waals interaction between the Te1 coupling two Te 1 - Bi - Te 2 - Bi - Te 1 five-layer quint substructures. However, we demonstrate here a surprising result that forming twin boundaries between the Te1 atoms of adjacent quints greatly strengthens the interaction between them, leading to a tripling of the ideal shear strength in nanotwinned Bi2Te3 (0.6 GPa) compared to that in the single crystalline material (0.19 GPa). This grain boundary engineering strategy opens a new pathway for designing robust Bi2Te3 TE semiconductors for high-performance TE devices.

  8. Programming Cardiac Resynchronization Therapy for Electrical Synchrony: Reaching Beyond Left Bundle Branch Block and Left Ventricular Activation Delay.

    Science.gov (United States)

    Varma, Niraj; O'Donnell, David; Bassiouny, Mohammed; Ritter, Philippe; Pappone, Carlo; Mangual, Jan; Cantillon, Daniel; Badie, Nima; Thibault, Bernard; Wisnoskey, Brian

    2018-02-06

    QRS narrowing following cardiac resynchronization therapy with biventricular (BiV) or left ventricular (LV) pacing is likely affected by patient-specific conduction characteristics (PR, qLV, LV-paced propagation interval), making a universal programming strategy likely ineffective. We tested these factors using a novel, device-based algorithm (SyncAV) that automatically adjusts paced atrioventricular delay (default or programmable offset) according to intrinsic atrioventricular conduction. Seventy-five patients undergoing cardiac resynchronization therapy (age 66±11 years; 65% male; 32% with ischemic cardiomyopathy; LV ejection fraction 28±8%; QRS duration 162±16 ms) with intact atrioventricular conduction (PR interval 194±34, range 128-300 ms), left bundle branch block, and optimized LV lead position were studied at implant. QRS duration (QRSd) reduction was compared for the following pacing configurations: nominal simultaneous BiV (Mode I: paced/sensed atrioventricular delay=140/110 ms), BiV+SyncAV with 50 ms offset (Mode II), BiV+SyncAV with offset that minimized QRSd (Mode III), or LV-only pacing+SyncAV with 50 ms offset (Mode IV). The intrinsic QRSd (162±16 ms) was reduced to 142±17 ms (-11.8%) by Mode I, 136±14 ms (-15.6%) by Mode IV, and 132±13 ms (-17.8%) by Mode II. Mode III yielded the shortest overall QRSd (123±12 ms, -23.9% [ P <0.001 versus all modes]) and was the only configuration without QRSd prolongation in any patient. QRS narrowing occurred regardless of QRSd, PR, or LV-paced intervals, or underlying ischemic disease. Post-implant electrical optimization in already well-selected patients with left bundle branch block and optimized LV lead position is facilitated by patient-tailored BiV pacing adjusted to intrinsic atrioventricular timing using an automatic device-based algorithm. © 2018 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  9. Real-time adjustment of ventricular restraint therapy in heart failure.

    Science.gov (United States)

    Ghanta, Ravi K; Lee, Lawrence S; Umakanthan, Ramanan; Laurence, Rita G; Fox, John A; Bolman, Ralph Morton; Cohn, Lawrence H; Chen, Frederick Y

    2008-12-01

    Current ventricular restraint devices do not allow for either the measurement or adjustment of ventricular restraint level. Periodic adjustment of restraint level post-device implantation may improve therapeutic efficacy. We evaluated the feasibility of an adjustable quantitative ventricular restraint (QVR) technique utilizing a fluid-filled polyurethane epicardial balloon to measure and adjust restraint level post-implantation guided by physiologic parameters. QVR balloons were implanted in nine ovine with post-infarction dilated heart failure. Restraint level was defined by the maximum restraint pressure applied by the balloon to the epicardium at end-diastole. An access line connected the balloon lumen to a subcutaneous portacath to allow percutaneous access. Restraint level was adjusted while left ventricular (LV) end-diastolic volume (EDV) and cardiac output was assessed with simultaneous transthoracic echocardiography. All nine ovine successfully underwent QVR balloon implantation. Post-implantation, restraint level could be measured percutaneously in real-time and dynamically adjusted by instillation and withdrawal of fluid from the balloon lumen. Using simultaneous echocardiography, restraint level could be adjusted based on LV EDV and cardiac output. After QVR therapy for 21 days, LV EDV decreased from 133+/-15 ml to 113+/-17 ml (p<0.05). QVR permits real-time measurement and physiologic adjustment of ventricular restraint therapy after device implantation.

  10. New Innovations in Circulatory Support With Ventricular Assist Device and Extracorporeal Membrane Oxygenation Therapy.

    Science.gov (United States)

    Sladen, Robert N

    2017-04-01

    The past decade has seen an exponential increase in the application and development of durable long-term as well as nondurable short-term mechanical circulatory support for cardiogenic shock and acute or chronic heart failure. Support has evolved from bridge-to-transplant to destination therapy, bridge to rescue, bridge to decision making, and bridge to a bridge. Notable trends include device miniaturization, minimally invasive and/or percutaneous insertion, and efforts to superimpose pulsatility on continuous flow. We can certainly anticipate that innovation will accelerate in the months and years to come. However, despite-or perhaps because of-the enhanced equipment now available, mechanical circulatory support is an expensive, complex, resource-intensive modality. It requires considerable expertise that should preferably be centralized to highly specialized centers. Formidable challenges remain: systemic inflammatory response syndromes and vasoplegia after device insertion; postoperative sepsis; optimal anticoagulation regimens to prevent device-induced thrombosis and cerebral thromboembolism; wound site, intracranial, and gastrointestinal bleeding; multisystem injury and failure; patient dissatisfaction (even when providers consider the procedure a "success"); and ethical decision making in conditions of futility.

  11. Vocational Reintegration of Handicapped Workers with Assistive Devices

    Science.gov (United States)

    Cooper, N. E.

    1977-01-01

    Two approaches to vocational reintegration of handicapped workers are described: (1) adapting the disabled to the working environment through treatment, therapy, counseling, selective placement, and prostheses, and (2) adapting the working environment to particular handicaps, with the assistive device fitted to the machine or tool rather than to…

  12. Synthesis of BiFeO{sub 3} thin films on single-terminated Nb : SrTiO{sub 3} (111) substrates by intermittent microwave assisted hydrothermal method

    Energy Technology Data Exchange (ETDEWEB)

    Velasco-Davalos, Ivan; Ambriz-Vargas, Fabian; Kolhatkar, Gitanjali; Thomas, Reji, E-mail: ruediger@emt.inrs.ca, E-mail: reji.thomas@emt.inrs.ca; Ruediger, Andreas, E-mail: ruediger@emt.inrs.ca, E-mail: reji.thomas@emt.inrs.ca [Centre Énergie, Matériaux et Télécommunications, INRS, 1650 Lionel-Boulet, Varennes, Québec, J3X1S2 (Canada)

    2016-06-15

    We report on a simple and fast procedure to create arrays of atomically flat terraces on single crystal SrTiO{sub 3} (111) substrates and the deposition of ferroelectric BiFeO{sub 3} thin films on such single-terminated surfaces. A microwave-assisted hydrothermal method in deionized water and ammonia solution selectively removes either (SrO{sub 3}){sup 4−} or Ti{sup 4+} layers to ensure the same chemical termination on all terraces. Measured step heights of 0.225 nm (d{sub 111}) and uniform contrast in the phase image of the terraces confirm the single termination in pure and Nb doped SrTiO{sub 3} single crystal substrates. Multiferroic BiFeO{sub 3} thin films were then deposited by the same microwave assisted hydrothermal process on Nb : SrTiO{sub 3} (111) substrates. Bi(NO{sub 3}){sub 3} and Fe(NO{sub 3}){sub 3} along with KOH served as the precursors solution. Ferroelectric behavior of the BiFeO{sub 3} films on Nb : SrTiO{sub 3} (100) substrates was verified by piezoresponse force microscopy.

  13. Surfactant-assisted hydrothermal fabrication and visible-light-driven photocatalytic degradation of methylene blue over multiple morphological BiVO4 single-crystallites

    International Nuclear Information System (INIS)

    Meng Xue; Zhang Lei; Dai Hongxing; Zhao Zhenxuan; Zhang Ruzhen; Liu Yuxi

    2011-01-01

    Monoclinic BiVO 4 single-crystallites with polyhedral, rod-like, tubular, leaf-like, and spherical morphologies have been fabricated using the triblock copolymer P123-assisted hydrothermal strategy with bismuth nitrate and ammonium metavanadate as metal source and various bases as pH adjustor. The physicochemical properties of the materials were characterized by means of the XRD, TGA/DSC, Raman, HRSEM, HRTEM/SAED, XPS, and UV-vis techniques. The photocatalytic activities of the as-fabricated BiVO 4 samples were measured for the photodegradation of methylene blue (MB) under visible-light irradiation. It is shown that factors, such as the pH value of precursor solution, the introduction of surfactant, the nature of alkaline source, and the hydrothermal temperature, have a crucial influence on the particle architecture of the BiVO 4 product. Among the as-fabricated BiVO 4 samples, the ones derived hydrothermally with P123 at pH = 6 or 10 possessed excellent optical absorption performance both in UV- and visible-light regions and hence showed outstanding photocatalytic activities for the addressed reaction. The unusually high visible-light-driven catalytic performance of monoclinically crystallized rod-like and tubular BiVO 4 single-crystallites is associated with the higher surface areas and concentrations of surface oxygen defects, and unique particle morphologies. The possible formation mechanisms of such multiple morphological BiVO 4 materials have also been discussed.

  14. Factors associated with anti-human leukocyte antigen antibodies in patients supported with continuous-flow devices and effect on probability of transplant and post-transplant outcomes

    DEFF Research Database (Denmark)

    Alba, Ana C; Tinckam, Kathryn; Foroutan, Farid

    2015-01-01

    BACKGROUND: One major disadvantage of ventricular assist device (VAD) therapy is the development of human-leukocyte antigen (HLA) antibodies. We aimed to identify factors associated with HLA antibodies during continuous flow (CF)-VAD support and assess the effect on transplant probability...

  15. Monitoring mobility assistive device use in post-stroke patients

    DEFF Research Database (Denmark)

    Boissy, Patrice; Hester, Todd; Sherrill, Delsey

    2007-01-01

    Mobility assistive devices (MAD) such as canes can improve mobility and allow independence in the performance of mobility-related tasks. The use of MAD is often prescribed for stroke survivors. Despite their acknowledged qualities, MAD in real life conditions are typically underutilized, misused...

  16. PediaFlow™ Maglev Ventricular Assist Device: A Prescriptive Design Approach.

    Science.gov (United States)

    Antaki, James F; Ricci, Michael R; Verkaik, Josiah E; Snyder, Shaun T; Maul, Timothy M; Kim, Jeongho; Paden, Dave B; Kameneva, Marina V; Paden, Bradley E; Wearden, Peter D; Borovetz, Harvey S

    2010-03-01

    This report describes a multi-disciplinary program to develop a pediatric blood pump, motivated by the critical need to treat infants and young children with congenital and acquired heart diseases. The unique challenges of this patient population require a device with exceptional biocompatibility, miniaturized for implantation up to 6 months. This program implemented a collaborative, prescriptive design process, whereby mathematical models of the governing physics were coupled with numerical optimization to achieve a favorable compromise among several competing design objectives. Computational simulations of fluid dynamics, electromagnetics, and rotordynamics were performed in two stages: first using reduced-order formulations to permit rapid optimization of the key design parameters; followed by rigorous CFD and FEA simulations for calibration, validation, and detailed optimization. Over 20 design configurations were initially considered, leading to three pump topologies, judged on the basis of a multi-component analysis including criteria for anatomic fit, performance, biocompatibility, reliability, and manufacturability. This led to fabrication of a mixed-flow magnetically levitated pump, the PF3, having a displaced volume of 16.6 cc, approximating the size of a AA battery and producing a flow capacity of 0.3-1.5 L/min. Initial in vivo evaluation demonstrated excellent hemocompatibility after 72 days of implantation in an ovine. In summary, combination of prescriptive and heuristic design principles have proven effective in developing a miniature magnetically levitated blood pump with excellent performance and biocompatibility, suitable for integration into chronic circulatory support system for infants and young children; aiming for a clinical trial within 3 years.

  17. Preliminary design of the internal geometry in a minimally invasive left ventricular assist device under pulsatile-flow conditions.

    Science.gov (United States)

    Smith, P Alex; Wang, Yaxin; Metcalfe, Ralph W; Sampaio, Luiz C; Timms, Daniel L; Cohn, William E; Frazier, O H

    2018-03-01

    A minimally invasive, partial-assist, intra-atrial blood pump has been proposed, which would unload the left ventricle with a flow path from the left atrium to the arterial system. Flow modulation is a common strategy for ensuring washout in the pump, but it can increase power consumption because it is typically achieved through motor-speed variation. However, if a pump's performance curve had the proper gradient, flow modulation could be realized passively. To achieve this goal, we propose a pump performance operating curve as an alternative to the more standard operating point. Mean-line theory was employed to generate an initial set of geometries that were then tested on a hydraulic test rig at ~20,000 r/min. Experimental results show that the intra-atrial blood pump performed below the operating region; however, it was determined that smaller hub diameter and longer chord length bring the performance of the intra-atrial blood pump device closer to the operating curve. We found that it is possible to shape the pump performance curve for specifically targeted gradients over the operating region through geometric variations inside the pump.

  18. Phase-Pure of BiFeO3 Ceramic Based on Citric Acid - Assisted Gel by Sintering Time Variation

    Science.gov (United States)

    Suastiyanti, Dwita; Ismojo

    2017-07-01

    Bismuth ferrite powder (BiFeO3/BFO) with high purity was synthesized by sol-gel process. It was used Bi5O(OH)9(NO3)4 and Fe(NO3)3.9H2O as main compound sources. Citric acid (C6H8O7) was used as fuell. As multiferroic material, BFO promises important technological applications in several devices like data strorage, spinotronics, sensor, actuator devices etc. This research would know the optimum process condition of sol-gel process to produce BFO powder by varying of sintering time. The novelty of this research is how to produce BFO in single phase by simple method. It was used calcination condition at 160°C for 4 hours and sintering condition at 600°C with varying of sintering time of 4, 6 and 8 hours. Thermogravimetric Analysis/Differential Thermal Analysis (TGA/DTA), X Ray Diffraction (XRD) and Scanning Electron Microscope (SEM) were used to characterize the powder. Loss of mass and heat flow were seen at TGA/DTA test at 160°C approximately (used as reference of calcination temperature). BFO powder sintered at for 8 hours has no secondary phase, meanwhile for another sintering time (4 and 6 hours) it has Bi2O3 as secondary phase. It is also show at SEM observation result that powder with sintering time of 8 hours has finer grain than of 4 and 6 hours sintering at the same temperature. The grains of BFO powder has heterogenous in size, shape and still agglomerated.

  19. Measurement of blood flow from an assist ventricle by computation of pneumatic driving parameters.

    Science.gov (United States)

    Qian, K X

    1992-03-01

    The measurement of blood flow from an assist ventricle is important but sometimes difficult in artificial heart experiments. Along with the development of a pneumatic cylinder-piston driver coupled with a ventricular assist device, a simplified method for measuring pump flow was established. From driving parameters such as the piston (or cylinder) displacement and air pressure, the pump flow could be calculated by the use of the equation of state for an ideal gas. The results of this method are broadly in agreement with electromagnetic and Doppler measurements.

  20. Magnet-assisted device-level alignment for the fabrication of membrane-sandwiched polydimethylsiloxane microfluidic devices

    International Nuclear Information System (INIS)

    Lu, J-C; Liao, W-H; Tung, Y-C

    2012-01-01

    Polydimethylsiloxane (PDMS) microfluidic device is one of the most essential techniques that advance microfluidics research in recent decades. PDMS is broadly exploited to construct microfluidic devices due to its unique and advantageous material properties. To realize more functionalities, PDMS microfluidic devices with multi-layer architectures, especially those with sandwiched membranes, have been developed for various applications. However, existing alignment methods for device fabrication are mainly based on manual observations, which are time consuming, inaccurate and inconsistent. This paper develops a magnet-assisted alignment method to enhance device-level alignment accuracy and precision without complicated fabrication processes. In the developed alignment method, magnets are embedded into PDMS layers at the corners of the device. The paired magnets are arranged in symmetric positions at each PDMS layer, and the magnetic attraction force automatically pulls the PDMS layers into the aligned position during assembly. This paper also applies the method to construct a practical microfluidic device, a tunable chaotic micromixer. The results demonstrate the successful operation of the device without failure, which suggests the accurate alignment and reliable bonding achieved by the method. Consequently, the fabrication method developed in this paper is promising to be exploited to construct various membrane-sandwiched PDMS microfluidic devices with more integrated functionalities to advance microfluidics research. (paper)

  1. Radionuclide assessment of left ventricular function in patients requiring intraoperative balloon pump assistance

    International Nuclear Information System (INIS)

    Davies, R.A.; Laks, H.; Wackers, F.J.; Berger, H.J.; Williams, B.; Hammond, G.L.; Geha, A.S.; Gottschalk, A.; Zaret, B.L.

    1982-01-01

    Twenty-three surviving patients who were weaned from cardiopulmonary bypass with intraaortic balloon pump assistance returned for follow-up radionuclide left ventricular (LV) function and thallium 201 perfusion studies at a mean of 23 +/- 3 months following operation. It was found that despite profound intraoperative myocardial depression requiring intraaortic balloon assistance, 13 patients had no change (within 10%) in the resting LV ejection fraction compared with the preoperative measurement. Among all 23 patients, there was no difference between mean (+/- standard error of the mean) preoperative and postoperative resting LV ejection fraction (48 +/- 4 vs 46 +/- 4%, p . not significant [NS]). Only 11 patients had perioperative myocardial infarction documented by new Q waves in the electrocardiogram, by elevation of creatine kinase-MB fraction, or by defects on thallium 201 imaging not explained by documented myocardial infarction before operation. Overall, postoperative resting LV ejection fraction was not different from the preoperative value in patients with perioperative myocardial infarction (44 +/- 7 vs 47 +/- 5%, p . NS). Postoperative resting LV ejection fraction rose by greater than 10% compared with preoperative values in 4 patients (3 with aortic valve replacement), remained within the 10% limit in 9 patients, and fell by greater than 10% in 10 patients (7 with perioperative myocardial infarction). Only 4 out of 16 patients studied at follow-up with exercise radionuclide studies demonstrated a normal LV response to exercise (greater than 5% increase in LV ejection fraction). Thus, among survivors requiring intraaortic balloon pump assistance for weaning from cardiopulmonary bypass, LV performance at rest is frequently preserved. In addition, 11 of the 23 patients had evidence of perioperative myocardial infarction, indicating a component of reversible intraoperative LV dysfunction

  2. Evaluation of ventricular function in patients with coronary artery disease

    International Nuclear Information System (INIS)

    Rocco, T.P.; Dilsizian, V.; Fischman, A.J.; Strauss, H.W.

    1989-01-01

    The recent expansion of interventional cardiovascular technologies has stimulated a concomitant expansion of noninvasive cardiac studies, both to assist in diagnosis and to evaluate treatment outcomes. Radionuclide ventricular function studies provide a reliable, reproducible means to quantify global left ventricular systolic performance, a critical determinant of prognosis in patients with cardiovascular disease. In addition, the ability to evaluate regional left ventricular wall motion and to assess ventricular performance during exercise have secured a fundamental role for such studies in the screening and treatment of patients with coronary artery disease. Radionuclide techniques have been extended to the evaluation of left ventricular relaxation/filling events, left ventricular systolic/diastolic function in the ambulatory setting, and with appropriate technical modifications, to the assessment of right ventricular performance at rest and with exercise. As a complement to radionuclide perfusion studies, cardiac blood-pool imaging allows for thorough noninvasive description of cardiac physiology and function in both normal subjects and in patients with a broad range of cardiovascular diseases. 122 references

  3. Investigation of the visible light photocatalytic activity of BiVO4 prepared by sol gel method assisted by ultrasonication.

    Science.gov (United States)

    Deebasree, J P; Maheskumar, V; Vidhya, B

    2018-07-01

    Visible light induced photocatalyst BiVO 4 with monoclinic scheelite structure has been synthesised via sol gel method assisted by ultrasonication. The prepared samples were characterised using X-ray diffraction (XRD), scanning electron microscope (SEM), UV-Vis diffused reflectance spectroscopy (DRS) techniques. The photocatalytic efficiency was evaluated by decolourisation of MB under visible light irradiation. The effect of ultrasound output power on the properties of BiVO 4 during and after preparation by sol-gel method has been compared with normal agitated sample (As prepared). The power of ultrasonic vibration has been varied and an ideal output power which yields better catalytic efficiency is determined. BiVO 4 sonicated with 80 W during preparation 80 W (D) exhibited relatively high surface area, better surface morphology and better catalytic efficiency compared to other samples which were sonicated with 100, 160 and 200 W. The results signify that the photodegradation rate of BiVO 4 80 W (D) sample is high up to 96% in 90 min compared to other samples. Change in morphology leading to better catalytic efficiency was obtained just by exposing the sample to ultrasonic radiation without addition of any surfactant. The recovery test showed that the sample was stable for four consecutive cycles. Using radical test, a reasonable mechanism for photodegradation has been proposed. Copyright © 2018 Elsevier B.V. All rights reserved.

  4. Development of Hand Grip Assistive Device Control System for Old People through Electromyography (EMG Signal Acquisitions

    Directory of Open Access Journals (Sweden)

    Khamis Herman

    2017-01-01

    Full Text Available The hand grip assistive device is a glove to assist old people who suffer from hand weakness in their daily life activities. The device earlier control system only use simple on and off switch. This required old people to use both hand to activate the device. The new control system of the hand grip assistive device was developed to allow single hand operation for old people. New control system take advantages of electromyography (EMG and flex sensor which was implemented to the device. It was programmed into active and semi-active mode operation. EMG sensors were placed on the forearm to capture EMG signal of Flexor Digitorum Profundus muscle to activate the device. Flex sensor was used to indicate the finger position and placed on top of the finger. The signal from both sensors then used to control the device. The new control system allowed single hand operation and designed to prevent user from over depended on the device by activating it through moving their fingers.

  5. High-risk medical devices, children and the FDA: regulatory challenges facing pediatric mechanical circulatory support devices.

    Science.gov (United States)

    Almond, Christopher S D; Chen, Eric A; Berman, Michael R; Less, Joanne R; Baldwin, J Timothy; Linde-Feucht, Sarah R; Hoke, Tracey R; Pearson, Gail D; Jenkins, Kathy; Duncan, Brian W; Zuckerman, Bram D

    2007-01-01

    Pediatric mechanical circulatory support is a critical unmet need in the United States. Infant- and child-sized ventricular assist devices are currently being developed largely through federal contracts and grants through the National Heart, Lung, and Blood Institute (NHLBI). Human testing and marketing of high-risk devices for children raises epidemiologic and regulatory issues that will need to be addressed. Leaders from the US Food and Drug Administration (FDA), NHLBI, academic pediatric community, and industry convened in January 2006 for the first FDA Workshop on the Regulatory Process for Pediatric Mechanical Circulatory Support Devices. The purpose was to provide the pediatric community with an overview of the federal regulatory process for high-risk medical devices and to review the challenges specific to the development and regulation of pediatric mechanical circulatory support devices. Pediatric mechanical circulatory support present significant epidemiologic, logistic, and financial challenges to industry, federal regulators, and the pediatric community. Early interactions with the FDA, shared appreciation of challenges, and careful planning will be critical to avoid unnecessary delays in making potentially life-saving devices available for children. Collaborative efforts to address these challenges are warranted.

  6. Beyond the VAD: Human Factors Engineering for Mechanically Assisted Circulation in the 21st Century.

    Science.gov (United States)

    Throckmorton, Amy L; Patel-Raman, Sonna M; Fox, Carson S; Bass, Ellen J

    2016-06-01

    Thousands of ventricular assist devices (VADs) currently provide circulatory support to patients worldwide, and dozens of heart pump designs for adults and pediatric patients are under various stages of development in preparation for translation to clinical use. The successful bench-to-bedside development of a VAD involves a structured evaluation of possible system states, including human interaction with the device and auxiliary component usage in the hospital or home environment. In this study, we review the literature and present the current landscape of preclinical design and assessment, decision support tools and procedures, and patient-centered therapy. Gaps of knowledge are identified. The study findings support the need for more attention to user-centered design approaches for medical devices, such as mechanical circulatory assist systems, that specifically involve detailed qualitative and quantitative assessments of human-device interaction to mitigate risk and failure. Copyright © 2015 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  7. Echocardiographic evaluation of right ventricular stroke work index in advanced heart failure: a new index?

    Science.gov (United States)

    Frea, Simone; Bovolo, Virginia; Bergerone, Serena; D'Ascenzo, Fabrizio; Antolini, Marina; Capriolo, Michele; Canavosio, Federico Giovanni; Morello, Mara; Gaita, Fiorenzo

    2012-12-01

    Right ventricular (RV) function plays a pivotal role in advanced heart failure patients, especially for screening those who may benefit from left ventricular assist device (LVAD) implantation. We introduce RV contraction pressure index (RVCPI) as a new echo-Doppler parameter of RV function. The accuracy of RVCPI in detecting RV failure was compared with the criterion standard, the RV stroke work index (RVSWI) obtained through right heart catheterization in advanced heart failure patients referred for heart transplantation or LVAD implantation. Right heart catheterization and echo-Doppler were simultaneously performed in 94 consecutive patients referred to our center for advanced heart failure (ejection fraction (EF) 24 ± 8.8%, 40% NYHA functional class IV). RV stroke volume and invasive pulmonary pressures were used to obtain RVSWI. Simplified RVCPI (sRVCPI) was derived as TAPSE × (RV - right atrial pressure gradient). Close positive correlation between sRVCPI and RVSWI was found (r = 0.68; P rights reserved.

  8. Electrochemical detection of volatile organic compounds using a Na{sub 3}Zr{sub 2}Si{sub 2}PO{sub 12}/Bi{sub 2}Cu{sub 0.1}V{sub 0.9}O{sub 5.35} heterojunction device

    Energy Technology Data Exchange (ETDEWEB)

    Kida, Tetsuya, E-mail: kida@mm.kyushu-u.ac.jp [Department of Energy and Material Sciences, Faculty of Engineering Sciences, Kyushu University, Kasuga-koen, Kasuga, Fukuoka 816-8580 (Japan); Morinaga, Naoki; Kishi, Shotaro [Department of Molecular and Material Sciences, Interdisciplinary Graduate School of Engineering Science, Kyushu University, Kasuga-Koen 6-1, Kasuga, Fukuoka 816-8580 (Japan); An, Ki-Mun; Sim, Kyoung-Won; Chae, Bu-Young [Department of Materials Science and Engineering, Pusan National University, 30 Jangjeon-dong, Geumjeong-gu, Busan 609-735 (Korea, Republic of); Kim, Jung-kwan [Education Center for Green Industry-friendly Fusion Technology (GIFT), Pusan National University, 30 Jangjeon-dong, Geumjeong-gu, Busan 609-735 (Korea, Republic of); Ryu, Bong-Ki [Department of Materials Science and Engineering, Pusan National University, 30 Jangjeon-dong, Geumjeong-gu, Busan 609-735 (Korea, Republic of); Shimanoe, Kengo [Department of Energy and Material Sciences, Faculty of Engineering Sciences, Kyushu University, Kasuga-koen, Kasuga, Fukuoka 816-8580 (Japan)

    2011-09-01

    Highlights: > A device combining a sodium ion conductor of NASICON (Na{sub 3}Zr{sub 2}Si{sub 2}PO{sub 12}) with an oxygen ion conductor of BiCuVOx (Bi{sub 2}Cu{sub 0.1}V{sub 0.9}O{sub 5.35}) was fabricated. > The device can electrochemically detect volatile organic compounds (VOCs). > The electrochemical oxidation of VOCs with oxide ions occurred as the sensing reaction. > The formation of an oxygen ion-conductive layer at the interface between NASICON and BiCuVOx was suggested. - Abstract: A fast sodium ion conductor, NASICON (Na{sub 3}Zr{sub 2}Si{sub 2}PO{sub 12}), has been widely used for gas sensor applications. In this study, we demonstrate that a device combining NASICON with an oxygen-ion conductor of BiCuVOx (Bi{sub 2}Cu{sub 0.1}V{sub 0.9}O{sub 5.35}) can electrochemically detect volatile organic compounds (VOCs), such as ethanol, formaldehyde, and toluene. The sensing electrode made of BiCuVOx was attached onto a sintered NASICON disk at high temperature to produce an interfacial layer that had a different morphology and composition from those of NASICON and BiCuVOx, as observed by scanning electron microscopy-energy dispersive X-ray spectroscopy analysis. The device in which NASICON was fitted with the BiCuVOx-based electrode was found to efficiently detect VOCs in ppm concentrations. The sensor signal (electromotive force) exceeded 100 mV in response to 10 ppm HCOH at 400 deg. C, demonstrating the high sensitivity of the device. It also exhibited a relatively quick response, reproducible and stable sensor signals, and high selectivity to VOCs. The sensor responses followed behavior typical for mixed-potential-type gas sensors based on oxygen-ion conductors. It was thus suggested that the electrochemical oxidation of VOCs with oxide ions took place at the interfacial oxygen ion-conductive layer that was formed by the reaction of NASICON with BiCuVOx.

  9. Optical spectroscopy and Fermi surface studies of BiTeCl and BiTeBr

    Science.gov (United States)

    Martin, Catalin; Suslov, A. V.; Buvaev, S.; Hebard, A. F.; Bugnon, Philippe; Berger, Helmuth; Magrez, Arnaud; Tanner, D. B.

    2014-03-01

    The observation of a large bulk Rashba effect in the non-centrosymmetric semiconductors BiTeX(X=Cl, Br, I) has stimulated the interest in these sys- tems, as promising candidates for studying spin related phenomena and for the realization of spin devices. Here we present a comparative study of the electronic properties of BiTeCl and BiTeBr, determined from temperature dependent infrared spectroscopy and Shubnikov-de Haas oscillations. In par- ticular, we compare the angle dependence of quantum oscillations between the two compounds and discuss possible differences between the topology of their Fermi surfaces. Supported by NSF Cooperative Agreement DMR-1157490 to the National High Magnetic Field Laboratory.

  10. Stroke rehabilitation: assistive technology devices and environmental modifications following primary rehabilitation in hospital--a therapeutic perspective

    DEFF Research Database (Denmark)

    Sørensen, Hanne Vinkel; Lendal, Susie; Schultz-Larsen, Kirsten

    2003-01-01

    The aim of this article is to describe the need for assistive devices and environmental modifications among long-living stroke survivors and to investigate if the need is continued and growing over time. The study sample of 155 consecutive stroke patients with stroke-related impairment, discharged...... home from three hospitals in Copenhagen from 1996 through 1998, constituted 20% of the total population of stroke survivors in this area. The results showed that 75% of these patients were provided with assistive devices and/or environmental modifications at discharge. Six months after discharge...... be required in order to target stroke survivors' changing needs for assistive devices and environmental modifications....

  11. Intraoperative device closure of perimembranous ventricular septal defects in the young children under transthoracic echocardiographic guidance; initial experience

    Directory of Open Access Journals (Sweden)

    Cao Hua

    2011-12-01

    Full Text Available Abstract Objectives This study aimed to assess the safety and feasibility of intraoperative device closure of perimembranous ventricular septal defects (VSD in young children guided by transthoracic echocardiography (TTE. Methods We enrolled 18 patients from our hospital to participate in the study from June 2011 to September 2011. A minimal inferior median incision was performed after full evaluation of the perimembranous VSD by real-time TTE, and a domestically made device was inserted to occlude the perimembranous VSD. The proper size of the device was determined by means of transthoracic echocardiographic analysis. Results Implantation was ultimately successful in 16 patients using TTE guidance. In these cases, the complete closure rate immediately following the operation and on subsequent follow-up was 100%. Symmetric devices were used in 14 patients, and asymmetric devices were used in two patients. Two patient were transformed to surgical treatment, one for significant residual shunting, and the other for unsuccessful wire penetration of the VSD. The follow-up periods were less than nine months, and only one patient had mild aortic regurgitation. There were no instances of residual shunt, noticeable aortic regurgitation, significant arrhythmia, thrombosis, or device failure. Conclusions Minimally invasive transthoracic device closure of perimembranous VSDs is safe and feasible, using a domestically made device under transthoracic echocardiographic guidance, without the need for cardiopulmonary bypass. This technique should be considered an acceptable alternative to surgery or device closure guided by transesophageal echocardiography in selected young children. However, a long-term evaluation of outcomes is necessary.

  12. Morphological evolution of Bi2Se3 nanocrystalline materials synthesized by microwave assisted solvothermal method

    Science.gov (United States)

    Bera, Sumit; Behera, P.; Mishra, A. K.; Krishnan, M.; Patidar, M. M.; Singh, D.; Gangrade, M.; Venkatesh, R.; Deshpande, U. P.; Phase, D. M.; Ganesan, V.

    2018-04-01

    Structural, morphological and spectroscopic properties of Bi2Se3 nanoparticles synthesized by microwave assisted solvothermal method were investigated systematically. A controlled synthesis of different morphologies by a small variation in synthesis procedure is demonstrated. Powder X-ray diffraction (XRD) confirmed the formation of single phase. Crystallite and particle size reductions were studied with XRD and AFM (Atomic Force Microscopy). Different morphologies such as hexagonal nanoflakes with cross section of around˜6µm, nanoflower and octahedral agglomerated crystals of nearly ˜60 nm size have been observed in scanning electron microscope while varying the microwave assisted synthesis procedures. A significant blue shift observed in diffuse reflectance spectroscopy evidences the energy gap tuning as a result of morphological evolution. The difference in morphology observed in this three fast, facile and scalable synthesis is advantageous for tuning the thermoelectric figure of merit and for probing the surface states of these topological insulators. Low temperature resistivity remains similar for all three variants depicting a 2D character as evidenced by a -lnT term of localization.

  13. Impact of interface charge on the electrostatics of field-plate assisted RESURF devices

    NARCIS (Netherlands)

    Boksteen, B.K.; Ferrara, A.; Heringa, A.; Steeneken, P.G.; Hueting, Raymond Josephus Engelbart

    2014-01-01

    A systematic study on the effects of arbitrary parasitic charge profiles, such as trapped or fixed charge, on the 2-D potential distribution in the drain extension of reverse-biased field-plate-assisted reduced surface field (RESURF) devices is presented. Using TCAD device simulations and analytical

  14. Sensor-Based Assistive Devices for Visually-Impaired People: Current Status, Challenges, and Future Directions

    Directory of Open Access Journals (Sweden)

    Wafa Elmannai

    2017-03-01

    Full Text Available The World Health Organization (WHO reported that there are 285 million visuallyimpaired people worldwide. Among these individuals, there are 39 million who are totally blind. There have been several systems designed to support visually-impaired people and to improve the quality of their lives. Unfortunately, most of these systems are limited in their capabilities. In this paper, we present a comparative survey of the wearable and portable assistive devices for visuallyimpaired people in order to show the progress in assistive technology for this group of people. Thus, the contribution of this literature survey is to discuss in detail the most significant devices that are presented in the literature to assist this population and highlight the improvements, advantages, disadvantages, and accuracy. Our aim is to address and present most of the issues of these systems to pave the way for other researchers to design devices that ensure safety and independent mobility to visually-impaired people.

  15. Sensor-Based Assistive Devices for Visually-Impaired People: Current Status, Challenges, and Future Directions

    Science.gov (United States)

    Elmannai, Wafa; Elleithy, Khaled

    2017-01-01

    The World Health Organization (WHO) reported that there are 285 million visually-impaired people worldwide. Among these individuals, there are 39 million who are totally blind. There have been several systems designed to support visually-impaired people and to improve the quality of their lives. Unfortunately, most of these systems are limited in their capabilities. In this paper, we present a comparative survey of the wearable and portable assistive devices for visually-impaired people in order to show the progress in assistive technology for this group of people. Thus, the contribution of this literature survey is to discuss in detail the most significant devices that are presented in the literature to assist this population and highlight the improvements, advantages, disadvantages, and accuracy. Our aim is to address and present most of the issues of these systems to pave the way for other researchers to design devices that ensure safety and independent mobility to visually-impaired people. PMID:28287451

  16. Late deterioration of left ventricular function after right ventricular pacemaker implantation.

    Science.gov (United States)

    Bellmann, Barbara; Muntean, Bogdan G; Lin, Tina; Gemein, Christopher; Schmitz, Kathrin; Schauerte, Patrick

    2016-09-01

    Right ventricular (RV) pacing induces a left bundle branch block pattern on ECG and may promote heart failure. Patients with dual chamber pacemakers (DCPs) who present with progressive reduction in left ventricular ejection fraction (LVEF) secondary to RV pacing are candidates for cardiac resynchronization therapy (CRT). This study analyzes whether upgrading DCP to CRT with the additional implantation of a left ventricular (LV) lead improves LV function in patients with reduced LVEF following DCP implantation. Twenty-two patients (13 males) implanted with DCPs and a high RV pacing percentage (>90%) were evaluated in term of new-onset heart failure symptoms. The patients were enrolled in this retrospective single-center study after obvious causes for a reduced LVEF were excluded with echocardiography and coronary angiography. In all patients, DCPs were then upgraded to biventricular devices. LVEF was analyzed with a two-sided t-test. QRS duration and brain natriuretic peptide (BNP) levels were analyzed with the unpaired t-test. LVEF declined after DCP implantation from 54±10% to 31±7%, and the mean QRS duration was 161±20 ms during RV pacing. NT-pro BNP levels were elevated (3365±11436 pmol/L). After upgrading to a biventricular device, a biventricular pacing percentage of 98.1±2% was achieved. QRS duration decreased to 108±16 ms and 106±20 ms after 1 and 6 months, respectively. There was a significant increase in LVEF to 38±8% and 41±11% and a decrease in NT-pro BNP levels to 3088±2326 pmol/L and 1860±1838 pmol/L at 1 and 6 months, respectively. Upgrading to CRT may be beneficial in patients with DCPs and heart failure induced by a high RV pacing percentage.

  17. The impact of mobility assistive technology devices on participation for individuals with disabilities.

    Science.gov (United States)

    Carver, Jordan; Ganus, Ashley; Ivey, Jon Mark; Plummer, Teresa; Eubank, Ann

    2016-08-01

    This study aims to address the gap in research and contribute to the body of knowledge on the perspectives assistive technology device users have toward their devices. Mixed methods were used to better understand the impact of mobility assistive technology devices (MATDs) on participation for individuals with disabilities. The Functional Mobility Assessment was administered in conjunction with two qualitative questions developed by the research team allowing participants to expound on the impact of their MATD experience. Participants were recruited online via the National Spinal Cord Injury Association website and in-person at Abilities Expo in Atlanta, Georgia, and the International Seating Symposium in Nashville, Tennessee. Results are consistent with findings from prior research regarding accessibility for individuals with disabilities. Corresponding findings were found in both the quantitative and qualitative data and are categorized into several major themes: environment (indoor and outdoor), surface heights, transportation, dependence, independence, quality of life and participation. Quantitative data from this study indicate that users of MATD are satisfied with the way in which their devices enable maneuvering indoors, while qualitative data suggest otherwise. Implications for healthcare practitioners are described and future recommendations are provided. Implications for Rehabilitation Healthcare professionals should advocate for proper mobility assistive technology devices (MATDs) for their patients in order to enable increased independence, safety and efficiency. Healthcare professionals must be cognizant of the impact of the environment and/or environmental barriers when prescribing MATD. Additional areas of interest for future research may include investigating the impact of MATD in association with date of onset of disability, according to diagnoses, or specific to length of time since acquiring the device.

  18. 14 CFR 382.121 - What mobility aids and other assistive devices may passengers with a disability bring into the...

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 4 2010-01-01 2010-01-01 false What mobility aids and other assistive... Aids, and Other Assistive Devices § 382.121 What mobility aids and other assistive devices may... or collapsible wheelchairs; (2) Other mobility aids, such as canes (including those used by persons...

  19. Risk stratification in patients with advanced heart failure requiring biventricular assist device support as a bridge to cardiac transplantation.

    Science.gov (United States)

    Cheng, Richard K; Deng, Mario C; Tseng, Chi-hong; Shemin, Richard J; Kubak, Bernard M; MacLellan, W Robb

    2012-08-01

    Prior studies have identified risk factors for survival in patients with end-stage heart failure (HF) requiring left ventricular assist device (LVAD) support. However, patients with biventricular HF may represent a unique cohort. We retrospectively evaluated a consecutive cohort of 113 adult, end-stage HF patients at University of California Los Angeles Medical Center who required BIVAD support between 2000 and 2009. Survival to transplant was 66.4%, with 1-year actuarial survival of 62.8%. All patients were Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) Level 1 or 2 and received Thoratec (Pleasanton, CA) paracorporeal BIVAD as a bridge to transplant. Univariate analyses showed dialysis use, ventilator use, extracorporal membrane oxygenation use, low cardiac output, preserved LV ejection fraction (restrictive physiology), normal-to-high sodium, low platelet count, low total cholesterol, low high-density and high-density lipoprotein, low albumin, and elevated aspartate aminotransferase were associated with increased risk of death. We generated a scoring system for survival to transplant. Our final model, with age, sex, dialysis, cholesterol, ventilator, and albumin, gave a C-statistic of 0.870. A simplified system preserved a C-statistic of 0.844. Patients were divided into high-risk or highest-risk groups (median respective survival, 367 and 17 days), with strong discrimination between groups for death. We have generated a scoring system that offers high prognostic ability for patients requiring BIVAD support and hope that it may assist in clinical decision making. Further studies are needed to prospectively validate our scoring system. Copyright © 2012 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

  20. Development and Validation of a Mobile Device-based External Ventricular Drain Simulator.

    Science.gov (United States)

    Morone, Peter J; Bekelis, Kimon; Root, Brandon K; Singer, Robert J

    2017-10-01

    Multiple external ventricular drain (EVD) simulators have been created, yet their cost, bulky size, and nonreusable components limit their accessibility to residency programs. To create and validate an animated EVD simulator that is accessible on a mobile device. We developed a mobile-based EVD simulator that is compatible with iOS (Apple Inc., Cupertino, California) and Android-based devices (Google, Mountain View, California) and can be downloaded from the Apple App and Google Play Store. Our simulator consists of a learn mode, which teaches users the procedure, and a test mode, which assesses users' procedural knowledge. Twenty-eight participants, who were divided into expert and novice categories, completed the simulator in test mode and answered a postmodule survey. This was graded using a 5-point Likert scale, with 5 representing the highest score. Using the survey results, we assessed the module's face and content validity, whereas construct validity was evaluated by comparing the expert and novice test scores. Participants rated individual survey questions pertaining to face and content validity a median score of 4 out of 5. When comparing test scores, generated by the participants completing the test mode, the experts scored higher than the novices (mean, 71.5; 95% confidence interval, 69.2 to 73.8 vs mean, 48; 95% confidence interval, 44.2 to 51.6; P mobile-based EVD simulator that is inexpensive, reusable, and accessible. Our results demonstrate that this simulator is face, content, and construct valid. Copyright © 2017 by the Congress of Neurological Surgeons

  1. Association between percutaneous hemodynamic support device and survival from cardiac arrest in the state of Michigan.

    Science.gov (United States)

    Pressman, Andrew; Sawyer, Kelly N; Devlin, William; Swor, Robert

    2018-05-01

    The role of circulatory support in the post-cardiac arrest period remains controversial. Our objective was to investigate the association between treatment with a percutaneous hemodynamic support device and outcome after admission for cardiac arrest. We performed a retrospective study of adult patients with admission diagnosis of cardiac arrest or ventricular fibrillation (VF) from the Michigan Inpatient Database, treated between July 1, 2010, and June 30, 2013. Patient demographics, clinical characteristics, treatments, and disposition were electronically abstracted based on ICD-9 codes at the hospital level. Mixed-effects logistic regression models were fit to test the effect of percutaneous hemodynamic support device defined as either percutaneous left ventricular assist device (pLVAD) or intra-aortic balloon pump (IABP) on survival. These models controlled for age, sex, VF, myocardial infarction (MI), and cardiogenic shock with hospital modeled as a random effect. A total of 103 hospitals contributed 4393 patients for analysis, predominately male (58.8%) with a mean age of 64.1years (SD 15.5). On univariate analysis, younger age, male sex, VF as the initial rhythm, acute MI, percutaneous coronary intervention, percutaneous hemodynamic support device, and absence of cardiogenic shock were associated with survival to discharge (each p<0.001). Mixed-effects logistic regressions revealed use of percutaneous hemodynamic support device was significantly associated with survival among all patients (OR 1.8 (1.28-2.54)), and especially in those with acute MI (OR 1.95 (1.31-2.93)) or cardiogenic shock (OR 1.96 (1.29-2.98)). Treatment with percutaneous hemodynamic support device in the post-arrest period may provide left ventricular support and improve outcome. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Advantages and disadvantages of using intravenous tissue Plasminogen activator as salvage therapy for inoperable HeartWare thrombosis.

    Science.gov (United States)

    Basken, Robyn; Bazzell, Charles M; Smith, Richard; Janardhanan, Rajesh; Khalpey, Zain

    2017-07-01

    Device thrombosis is a devastating complication of left ventricular assist devices. The definitive treatment has been device exchange or explant. Evidence of increasing morbidity and mortality with device exchange has shifted strategies toward conservative management. In this report, we detail the use of thrombolytics as salvage therapy in a patient with an occlusive HeartWare ventricular assist device (HeartWare Inc., Framingham, MA) thrombus, resulting in long-term survival without further intervention. © 2017 Wiley Periodicals, Inc.

  3. Resistance–temperature relation and atom cluster estimation of In–Bi system melts

    International Nuclear Information System (INIS)

    Geng, Haoran; Wang Zhiming; Zhou Yongzhi; Li Cancan

    2012-01-01

    Highlights: ► A testing device was adopted to measure the electrical resistivity of In–Bi system melts. ► A basically linear relation exists between the resistivity and temperature of In x Bi 100−x melts in measured temperature range. ► Based on Novakovic's assumption, the content of InBi atomic cluster in In x Bi 100−x melt is estimated with ρ ≈ ρ InBi x InBi + ρ m (1 − x InBi ) equation. - Abstract: A testing device for the resistivity of high-temperature melt was adopted to measure the l resistivity of In–Bi system melts at different temperatures. It can be concluded from the analysis and calculation of the experimental results that the resistivity of In x Bi 100−x (x = 0–100) melt is in linear relationship with temperature within the experiment temperature range. The resistivity of the melt decreases with the increasing content of In. The fair consistency of resistivity of In–Bi system melt is found in the heating and cooling processes. On the basis of Novakovic's assumption, we approximately estimated the content of InBi atom clusters in In x Bi 100−x melts with the resistivity data by equation ρ ≈ ρ InBi x InBi + ρ m (1 − x InBi ). In the whole components interval, the content corresponds well with the mole fraction of InBi clusters calculated by Novakovic in the thermodynamic approach. The mole fraction of InBi type atom clusters in the melts reaches the maximum at the point of stoichiometric composition In 50 Bi 50 .

  4. Transcatheter closure of ventricular septal defect with Occlutech Duct Occluder.

    Science.gov (United States)

    Atik-Ugan, Sezen; Saltik, Irfan Levent

    2018-04-01

    Patent ductus arteriosus occluders are used for transcatheter closure of ventricular septal defects, as well as for closure of patent ductus arteriosus. The Occlutech Duct Occluder is a newly introduced device for transcatheter closure of patent ductus arteriosus. Here, we present a case in which the Occlutech Duct Occluder was successfully used on a patient for the closure of a perimembraneous ventricular septal defect.

  5. Intelligent speed adaptation as an assistive device for drivers with acquired brain injury

    DEFF Research Database (Denmark)

    Klarborg, Brith; Lahrmann, Harry Spaabæk; Agerholm, Niels

    2012-01-01

    Intelligent speed adaptation (ISA) was tested as an assistive device for drivers with an acquired brain injury (ABI). The study was part of the “Pay as You Speed” project (PAYS) and used the same equipment and technology as the main study (Lahrmann et al., in press-a, in press-b). Two drivers......, and in general they described driving with ISA as relaxed. ISA reduced the percentage of the total distance that was driven with a speed above the speed limit (PDA), but the subjects relapsed to their previous PDA level in Baseline 2. This suggests that ISA is more suited as a permanent assistive device (i...

  6. Double-chambered right ventricle, ventricular septal defect, patent ductus arteriosus in a dog

    Energy Technology Data Exchange (ETDEWEB)

    Morozumi, M. [Togasaki Animal Hospital, Misato, Saitama (Japan); Kurosu, Y.; Kogure, K.; Chimura, S.; Shibata, S.; Kanemoto, I.

    1989-12-15

    A 4-month-old female mongrel puppy was presented with an anophthalmos. On physical examination, systolic murmur was heard at the 4th left intercostal space near the sternum. However the dog appeared healthy without cyanosis and had no history of exercise intolerance. The phonocardiogram revealed a pansystolic murmur and a continuous murmur on the mitral area. A systolic ejection murmur was also recorded on the pulmonic area. The electrocardiogram indicated bi-ventricular hypertrophy. Left ventricular enlargement was seen on chest radiographs. Ventricular septal defect (VSD) and patent ductus arteriosus (PDA) were diagnosed from these findings. PDA closure was performed at 2 years of age. After 2 months from the operation, the dog died during an attempted repair of the VSD. At necropsy, it was found that the double-chambered right ventricle (DCRV) was formed by an anomalous septal band. The VSD was localized on the proximal conus and was 8 mm in diameter. (author)

  7. Double-chambered right ventricle, ventricular septal defect, patent ductus arteriosus in a dog

    International Nuclear Information System (INIS)

    Morozumi, M.; Kurosu, Y.; Kogure, K.; Chimura, S.; Shibata, S.; Kanemoto, I.

    1989-01-01

    A 4-month-old female mongrel puppy was presented with an anophthalmos. On physical examination, systolic murmur was heard at the 4th left intercostal space near the sternum. However the dog appeared healthy without cyanosis and had no history of exercise intolerance. The phonocardiogram revealed a pansystolic murmur and a continuous murmur on the mitral area. A systolic ejection murmur was also recorded on the pulmonic area. The electrocardiogram indicated bi-ventricular hypertrophy. Left ventricular enlargement was seen on chest radiographs. Ventricular septal defect (VSD) and patent ductus arteriosus (PDA) were diagnosed from these findings. PDA closure was performed at 2 years of age. After 2 months from the operation, the dog died during an attempted repair of the VSD. At necropsy, it was found that the double-chambered right ventricle (DCRV) was formed by an anomalous septal band. The VSD was localized on the proximal conus and was 8 mm in diameter. (author)

  8. Bioartificial liver assist devices in support of patients with liver failure.

    Science.gov (United States)

    Patzer II, John F; Lopez, Roberto C; Zhu, Yue; Wang, Zi-Fa; Mazariegos, George V; Fung, John J

    2002-02-01

    Bioartificial liver assist devices (BALs) offer an opportunity for critical care physicians and transplant surgeons to stabilize patients prior to orthotopic liver transplantation. Such devices may also act as a bridge to transplant, providing liver support to patients awaiting transplant, or as support for patients post living-related donor transplant. Four BAL devices that rely on hepatocytes cultured in hollow fiber membrane cartridges (Circe Biomedical HepatAssist(r), Vitagen ELADTM, Gerlach BELS, and Excorp Medical BLSS) are currently in various stages of clinical evaluation. Comparison of the four devices shows that several unique approaches based upon the same overall system architecture are possible. Preliminary results of the Excorp Medical BLSS Phase I safety evaluation at the University of Pittsburgh, after treating four patients (F, 41, acetominophen-induced, two support periods; M, 50, Wilson's disease, one support period; F, 53, acute alcoholic hepatitis, two support periods; F, 24, chemotherapy-induced, one support period, are presented. All patients presented with hypoglycemia and transient hypotension at the start of extracorporeal perfusion. Hypoglycemia was treated by IV dextrose and the transient hypotension responded positively to IV fluid bolus. Heparin anticoagulation was used only in the second patient. No serious or adverse events were noted in the four patients. Moderate Biochemical response to support was noted in all patients. More complete characterization of the safety of the BLSS requires completion of the Phase I safety evaluation.

  9. Fiber Bragg grating sensor-based communication assistance device

    Science.gov (United States)

    Padma, Srivani; Umesh, Sharath; Pant, Shweta; Srinivas, Talabattula; Asokan, Sundarrajan

    2016-08-01

    Improvements in emergency medicine in the form of efficient life supporting systems and intensive care have increased the survival rate in critically injured patients; however, in some cases, severe brain and spinal cord injuries can result in a locked-in syndrome or other forms of paralysis, and communication with these patients may become restricted or impossible. The present study proposes a noninvasive, real-time communication assistive methodology for those with restricted communication ability, employing a fiber Bragg grating (FBG) sensor. The communication assistive methodology comprises a breath pattern analyzer using an FBG sensor, which acquires the exhalation force that is converted into strain variations on a cantilever. The FBG breath pattern analyzer along with specific breath patterns, which are programmed to give specific audio output commands, constitutes the proposed fiber Bragg grating sensor-based communication assistive device. The basic communication can be carried out by instructing the patients with restricted communication ability to perform the specific breath patterns. The present approach is intended to be an alternative to the common approach of brain-computer interface in which an instrument is utilized for learning of brain responses.

  10. The HeartShield device reduces the risk for right ventricular damage in patients with deep sternal wound infection.

    Science.gov (United States)

    Ingemansson, Richard; Malmsjö, Malin; Lindstedt, Sandra

    2014-01-01

    Right ventricular rupture, resulting in serious bleeding, is a life-threatening complication associated with negative-pressure wound therapy (NPWT) in cardiac surgery. The use of a rigid barrier between the heart and the sharp sternal edges has been successfully tested on pigs. In the present article, we demonstrate increased safety in NPWT through the use of the HeartShield device. Six patients were treated with a specially designed device in combination with NPWT. The device consists of a horizontally placed disk covered in foam. The back of the T-shaped device sticks up between the sternal edges and up above skin level. This part of the device is also covered in foam. Drainage is performed through two holes at the top of the device. The device and foam are changed every second to third day, and -120 mm Hg of continuous therapy is used. Six patients were treated with traditional NPWT, serving as control group. No signs of calluslike formation were seen on the right ventricle in the group treated with the HeartShield device. In the conventional NPWT control group, all six patients had calluslike formation (>1 × 2 cm2) on the anterior part of the right ventricle. All patients in the HeartShield group had grade 1 epicardial petechial bleeding (the right ventricle. In the control group, one patient had grade 1 (2.0 cm2) epicardial petechial bleeding on the right ventricle. No major bleeding or mortality was observed in either group during the course of the study. The use of the HeartShield device significantly minimizes the contact between the right ventricle and the sternal edges, thereby decreasing the risk for life-threatening complications due to bleeding.

  11. The Communication and Bioethical Training (CoBiT) Program for assisting dialysis decision-making in Spanish ACKD units.

    Science.gov (United States)

    García-Llana, Helena; Bajo, Maria-Auxiliadora; Barbero, Javier; Selgas, Rafael; Del Peso, Gloria

    2017-04-01

    Healthcare professionals currently working in Advanced Chronic Kidney Disease (ACKD) units must cope with difficult situations regarding assisting patients with the dialysis decision-making process, and they are often untrained for these conversations. Although we have evidence from the literature that these skills can be learned, few professionals feel confident in this area. A Communication and Bioethical Training (CoBiT) Program for ACKD staff (physicians, nurses and allied health professionals) was developed to improve their ability and self-confidence in conducting these conversations. A four-stage study was conducted: (1) development of the CoBiT program, beginning with the creation of an interdisciplinary focus group (N = 10); (2) design of a questionnaire to assess self-confidence based on the areas identified by the focus group. The face validity of the instrument was tested using an inter-judge methodology (N = 6); (3) design of the format and contents of the program; (4) piloting the program. Thirty-six health professionals took an 8-h workshop based on role-playing methodology. Participants assessed their self-confidence in their communication skills before and after the program using self-report measures. The results show that after the program, participants reported significantly higher levels of self-confidence measured with a five-point Likert scale (p CoBiT program improves ACKD Unit healthcare professionals' self-confidence in their ability to perform a specific communication task.

  12. Design, analysis, and testing of a flexure-based vibration-assisted polishing device

    Science.gov (United States)

    Gu, Yan; Zhou, Yan; Lin, Jieqiong; Lu, Mingming; Zhang, Chenglong; Chen, Xiuyuan

    2018-05-01

    A vibration-assisted polishing device (VAPD) composed of leaf-spring and right-circular flexure hinges is proposed with the aim of realizing vibration-assisted machining along elliptical trajectories. To design the structure, energy methods and the finite-element method are used to calculate the performance of the proposed VAPD. An improved bacterial foraging optimization algorithm is used to optimize the structural parameters. In addition, the performance of the VAPD is tested experimentally. The experimental results indicate that the maximum strokes of the two directional mechanisms operating along the Z1 and Z2 directions are 29.5 μm and 29.3 μm, respectively, and the maximum motion resolutions are 10.05 nm and 10.01 nm, respectively. The maximum working bandwidth is 1,879 Hz, and the device has a good step response.

  13. TongueToSpeech (TTS): Wearable wireless assistive device for augmented speech.

    Science.gov (United States)

    Marjanovic, Nicholas; Piccinini, Giacomo; Kerr, Kevin; Esmailbeigi, Hananeh

    2017-07-01

    Speech is an important aspect of human communication; individuals with speech impairment are unable to communicate vocally in real time. Our team has developed the TongueToSpeech (TTS) device with the goal of augmenting speech communication for the vocally impaired. The proposed device is a wearable wireless assistive device that incorporates a capacitive touch keyboard interface embedded inside a discrete retainer. This device connects to a computer, tablet or a smartphone via Bluetooth connection. The developed TTS application converts text typed by the tongue into audible speech. Our studies have concluded that an 8-contact point configuration between the tongue and the TTS device would yield the best user precision and speed performance. On average using the TTS device inside the oral cavity takes 2.5 times longer than the pointer finger using a T9 (Text on 9 keys) keyboard configuration to type the same phrase. In conclusion, we have developed a discrete noninvasive wearable device that allows the vocally impaired individuals to communicate in real time.

  14. Postinfarction Ventricular Septal Rupture – A Rare Complication Remains Challenge for Cardiac Surgical Team

    Directory of Open Access Journals (Sweden)

    Vilém Rohn

    2013-01-01

    Full Text Available The incidence of post infarction ventricular septal rupture (PIVSR is decreasing in the last years due to aggressive treatment of myocardial infarction with early percutaneous coronary interventions. As a consequence patients with PIVSR are referred to surgery more often with significant heart failure. The aim of this retrospective study was to assess the influence of these on the operative results and to identify the risk factors of operative mortality. A retrospective analysis of prospectively collected data of patients with the PIVSR admitted to our center from November 2004 to February 2012 was performed. Variables were analyzed using two-dimensional correspondence analysis. There were 25 patients (12 males and 13 females with mean age 70.2 years (47–82 operated on; 17 (68% presented with anterior and 8 (32% with posterior PIVSR. Eighteen patients (72% had acute heart failure, 13 (52% presented with cardiogenic shock. Before surgery, intraaortic balloon pump (IABP had 20 (80% patients; in 4 (16% a ventricular assist device was used, either Extracorporeal Membrane Oxygenation (ECMO or centrifugal pumps as biventricular assist. Operative mortality was 40% (10 pts.. Four patients (12% had small non-significant recurrent shunt on postoperative echocardiography. Although majority of patients with PIVSR have significant heart failure prior to surgery the operative mortality remains comparable to older studies. Predictors of perioperative death were concomitant surgical reconstruction of the left ventricle, renal impairment before operation, male gender, history of coronary artery disease, PIVSR location posterior, and shock at surgery.

  15. Conventional radiography and computed tomography of cardiac assist devices

    Energy Technology Data Exchange (ETDEWEB)

    Scheffel, Hans; Stolzmann, Paul; Desbiolles, Lotus; Leschka, Sebastian; Frauenfelder, Thomas; Schertler, Thomas; Marincek, Borut; Alkadhi, Hatem [University Hospital Zurich, Institute of Diagnostic Radiology, Zurich (Switzerland); Wilhelm, Markus J.; Lachat, Mario [University Hospital Zurich, Clinic for Cardiovascular Surgery, Zurich (Switzerland)

    2009-09-15

    Patients intended for circulatory support by cardiac assist devices (CAD) usually suffer from end-stage acute or chronic heart failure. Since the introduction of CAD in 1963 by DeBakey and coworkers, the systems have gone through a substantial evolution and have been increasingly used in the intervening decades. The spectrum of CAD includes a variety of systems serving to assist the systolic function of the left ventricle, the right ventricle, or both. Conventional radiography and multislice spiral computed tomography (CT) are the most commonly used radiological techniques for imaging patients with a CAD. CT is very useful for evaluating CAD systems by using both two- and three-dimensional reconstructions of the volumetric data sets. The two techniques together allow for the comprehensive assessment of patients with devices by imaging the in- and outflow cannulae, the anastomoses, the position of the pump, as well as associated complications. A close collaboration with cardiac surgeons with expertise in the field of circulatory support is deemed necessary for adequate image interpretation. This article describes the technical diversity of the currently available CAD systems. The imaging characteristics on conventional radiography and multislice spiral CT as well as the typical complications of their use are demonstrated. (orig.)

  16. Cross-cultural adaptation of the assistive technology device - Predisposition assessment (ATD PA) for use in Brazil (ATD PA Br).

    Science.gov (United States)

    Alves, Ana Cristina de Jesus; Matsukura, Thelma Simões; Scherer, Marcia J

    2017-02-01

    The purpose of this study is to conduct a cross-cultural adaptation of the Assistive Technology Device Predisposition Assessment (ATD PA) for use in Brazil. The selection of the Assistive Technology Device Predisposition Assessment (ATD PA) was determined by previous literature reviews of articles published in 2014 and 2016 in six databases with the terms "assistive device" or "assistive technology" or "self-help device" combined with "evidence-based practice" or "framework" or "measurement scale" or "model and outcome assessment". This review indicated that the conceptual model of Assistive Technology (AT) most discussed in the literature was the Matching Person and Technology (MPT) model, and this finding determined the selection of ATD PA as an assessment within the MPT portfolio of measures. The procedures for cross-cultural adaptation were as follows: Equivalence of Concept, Semantic and Operational. Five experts were asked to translate 725 items and these translations were evaluated and a high level of agreement was demonstrated. The Portuguese version, Avaliação de Tecnologia Assistiva - Predisposição ao Uso - ATD PA Br, was derived from the original version in English (ATD PA). The ATD PA Br will support professionals and people with disabilities in Brazil to better select AT devices according to the clients' needs. Implications for rehabilitation Provides a systematic way of selecting assistive technology devices for the use of individuals with disabilities according to the Brazilian reality. A systematic way of selecting the assistive technology that can help decrease the abandonment of the assistive technology use. The use of the Matching Person and Technology theorical model and of the assessment ATD PA Br is essential to guide the researches and clinical practice in Brazil.

  17. Taking a back seat

    DEFF Research Database (Denmark)

    Egerod, Ingrid; Overgaard, Dorthe

    2012-01-01

    As more patients with cardiac failure are being bridged to transplantation with left ventricular assist devices (LVAD), more insight into the lives of their close relatives is needed.......As more patients with cardiac failure are being bridged to transplantation with left ventricular assist devices (LVAD), more insight into the lives of their close relatives is needed....

  18. A Systematic Review on Existing Measures for the Subjective Assessment of Rehabilitation and Assistive Robot Devices

    Directory of Open Access Journals (Sweden)

    Yiannis Koumpouros

    2016-01-01

    Full Text Available The objective of the current study is to identify and classify outcome measures currently used for the assessment of rehabilitation or assistive robot devices. We conducted a systematic review of the literature using PubMed, MEDLINE, CIRRIE, and Scopus databases for studies that assessed rehabilitation or assistive robot devices from 1980 through January 2016. In all, 31 articles met all inclusion criteria. Tailor-made questionnaires were the most commonly used tool at 66.7%, while the great majority (93.9% of the studies used nonvalidated instruments. The study reveals the absence of a standard scale which makes it difficult to compare the results from different researchers. There is a great need, therefore, for a valid and reliable instrument to be available for use by the intended end users for the subjective assessment of robot devices. The study concludes by identifying two scales that have been validated in general assistive technology devices and could support the scope of subjective assessment in rehabilitation or assistive robots (however, with limited coverage and a new one called PYTHEIA, recently published. The latter intends to close the gap and help researchers and developers to evaluate, assess, and produce products that satisfy the real needs of the end users.

  19. Efecto de la localización del electrodo ventricular derecho (tracto de salida vs. ápex sobre la sincronía ventricular mecánica, en pacientes sometidos a terapia de implante de marcapaso cardiaco Effect of right ventricular electrode location (outflow tract vs. apex on mechanical ventricular synchrony in patients that underwent pacemaker implant therapy

    Directory of Open Access Journals (Sweden)

    Oscar S Rincón

    2008-12-01

    Full Text Available Objetivo: evaluar a profundidad el efecto de la estimulación ventricular desde el tracto de salida del ventrículo derecho y el ápex, sobre la sincronía ventricular mecánica. Materiales y métodos: estudio analítico de cohorte, en el que se realizó ecocardiograma transtorácico pre y post implante de marcapaso a 20 pacientes (diez por cada grupo con indicación de marcapaso definitivo, con implante del electrodo en el tracto de salida del ventrículo derecho y el ápex, sin cardiopatía estructural, fracción de eyección > 50%; QRS y conducción aurículo-ventricular normal, con el fin de evaluar la asincronía ventricular mecánica (modo M y Doppler tisular y los parámetros de implante y programación del dispositivo. Análisis estadístico: los resultados se presentan como promedios, desviación estándar o porcentajes. Las variables continuas se compararon utilizando prueba Chi cuadrado y ANOVA. Se consideró como estadísticamente significativa una p Objective: to assess in depth the effect of ventricular stimulation from the right ventricular outflow tract and the apex on mechanical ventricular synchrony. Materials and Methods: cohort analytical study. 20 patients with indication of definitive pacemaker indication underwent transthoracic echocardiogram before and after pacemaker implant with electrode implantation in the right ventricular outflow tract and in the apex (10 patients in each group. There was no structural cardiopathy, ejection fraction was > 50%, QRS and AV conduction were normal. Mechanical ventricular asynchrony (M mode and tissue doppler and implant and device parameters were evaluated. Statistical Analysis: results are given as mean values, standard deviation or percentages. Continuous variables were compared using Chi-square test and ANOVA. A p <0.05 value was considered statistically significant. Results: in five patients (25% a pre-implant ventricular asynchrony was found; in seven (70% ventricular asynchrony

  20. A wound retraction device for laparoscopic-assisted intestinal surgery in dogs and cats.

    Science.gov (United States)

    Gower, Sara B; Mayhew, Philipp D

    2011-06-01

    To report experience with laparoscopic-assisted intestinal resection and anastomosis for treatment of discrete intestinal masses using a novel wound retraction device. Case series. Dogs (n=2) and cats (6). Dogs and cats with discrete intestinal masses identified by ultrasonography without evidence of intestinal perforation or peritonitis, were included. A 2 portal technique was used; 1 portal was enlarged for insertion of the wound retraction device through which the intestine was examined as thoroughly as possible. The diseased portion of the intestine was exteriorized through the wound retractor and resection and anastomosis of the intestinal mass performed. Of the 8 animals, laparoscopic-assisted intestinal resection and anastomosis through the wound retractor was performed in 2 dogs and 3 cats. In 3 cats, based on either location or extent of the lesion, 2 were converted to laparoscopic-assisted intestinal biopsies and 1 to an open colocolostomy. No other intra- or perioperative complications were encountered and all animals survived to discharge. Laparoscopic-assisted intestinal resection and anastomosis can be performed in select canine and feline patients with modestly sized, discrete intestinal masses. © Copyright 2011 by The American College of Veterinary Surgeons.

  1. Percutaneous excisional biopsy of clinically benign breast lesions with vacuum-assisted system: comparison of three devices.

    Science.gov (United States)

    Wang, Zhi Li; Liu, Gang; Huang, Yan; Wan, Wen Bo; Li, Jun Lai

    2012-04-01

    The aim of this study was to compare three devices in percutaneous excisional biopsy of clinically benign breast lesions in terms of complete excision rate, duration of procedure and complications. In a retrospective study from March 2005 to May 2009, 983 lesions underwent ultrasound-guided excisional biopsy with three vacuum-assisted systems, respectively. The lesions were category 3 lesions as determined by ultrasound imaging according to Breast Imaging Reporting and Data System (BI-RADS) (n=951) or had been confirmed as benign by a previous core needle biopsy (n=32). The completely excision rate, duration of procedure and complications (hematoma, pain and ecchymosis) were recorded. 99.7% (980/983) lesions were demonstrated to be benign by pathology after percutaneous excisional biopsy. The overall complete excision rate was 94.8% (932/983). In lesions whose largest diameter equal to or larger than 1.5cm, the complete excision rates of EnCor(®) group (97.8%, 348/356) and Mammotome(®) group (97.2%, 139/143) were significantly higher than that of Vacora(®) group (91.9%, 445/484) (P<0.05). The EnCor(®) group (6.6±6.5min) had a significant less duration than Mammotome(®) (10.6±9.3min) and Vacora(®) group (25.6±23.3min) (P<0.05). Hematoma occurred more in EnCor(®) group and Mammotome(®) group than in Vacora(®) group (P<0.05). All these three vacuum-assisted systems are highly successful for excisional biopsy of benign breast lesions. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  2. 49 CFR 39.93 - What wheelchairs and other assistive devices may passengers with a disability bring onto a...

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 1 2010-10-01 2010-10-01 false What wheelchairs and other assistive devices may passengers with a disability bring onto a passenger vessel? 39.93 Section 39.93 Transportation Office of the... and Services to Passengers With Disabilities § 39.93 What wheelchairs and other assistive devices may...

  3. Bistable minimum energy structures (BiMES) for binary robotics

    International Nuclear Information System (INIS)

    Follador, M; Conn, A T; Rossiter, J

    2015-01-01

    Bistable minimum energy structures (BiMES) are devices derived from the union of the concepts of dielectric elastomer minimum energy structures and bistable systems. This article presents this novel approach to active, elastic and bistable structures. BiMES are based on dielectric elastomer actuators (DEAs), which act as antagonists and provide the actuation for switching between the two equilibrium positions. A central elastic beam is the backbone of the structure and is buckled into the minimum energy configurations by the action of the two DEAs. The theory and the model of the device are presented, and also its fabrication process. BiMES are considered as fundamental units for more complex structures, which are presented and fabricated as proof of concept. Two different ways of combining the multiple units are proposed: a parallel configuration, to make a simple gripper, and a serial configuration, to generate a binary device. The possibility of using the bistable system as a continuous bender actuator, by modulating the actuation voltage of the two DEAs, was also investigated. (paper)

  4. Extraction of the Electric Field in Field Plate Assisted RESURF Devices

    NARCIS (Netherlands)

    Boksteen, B.K.; Dhar, S.; Heringa, A.; Koops, G.E.J.; Hueting, Raymond Josephus Engelbart

    2012-01-01

    It has previously been reported that the lateral electric field (Ex) in the drain extension of thin SOI HV (700V) field plate assisted RESURF devices can be extracted from their ID-VD characteristics in the subthreshold regime. In this work the prerequisites for valid field extraction and the

  5. Ab initio assisted process modeling for Si-based nanoelectronic devices

    International Nuclear Information System (INIS)

    Windl, Wolfgang

    2005-01-01

    In this paper, we discuss concepts and examples of ab initio calculations assisting physics-based process simulation. We focus on how to determine diffusion and reaction constants, where modern methods such as the nudged elastic band method allow a systematic and reliable search for the minimum energy migration path and barrier. We show that once the saddle point is determined, the underlying harmonic transition state theory also allows to calculate the prefactors. The discussed examples include nitrogen diffusion, boron deactivation and boron interface segregation. Finally, some concepts are discussed for future device technologies such as molecular devices, where the currently prevalent multiscale approach (kinetic parameters used in higher level models like diffusion-reaction or kinetic Monte Carlo modeling) would not be sensible anymore. As an example, we described the ab initio temperature-accelerated dynamics modeling of contact formation in carbon nanotube devices

  6. Wireless sEMG-Based Body-Machine Interface for Assistive Technology Devices.

    Science.gov (United States)

    Fall, Cheikh Latyr; Gagnon-Turcotte, Gabriel; Dube, Jean-Francois; Gagne, Jean Simon; Delisle, Yanick; Campeau-Lecours, Alexandre; Gosselin, Clement; Gosselin, Benoit

    2017-07-01

    Assistive technology (AT) tools and appliances are being more and more widely used and developed worldwide to improve the autonomy of people living with disabilities and ease the interaction with their environment. This paper describes an intuitive and wireless surface electromyography (sEMG) based body-machine interface for AT tools. Spinal cord injuries at C5-C8 levels affect patients' arms, forearms, hands, and fingers control. Thus, using classical AT control interfaces (keypads, joysticks, etc.) is often difficult or impossible. The proposed system reads the AT users' residual functional capacities through their sEMG activity, and converts them into appropriate commands using a threshold-based control algorithm. It has proven to be suitable as a control alternative for assistive devices and has been tested with the JACO arm, an articulated assistive device of which the vocation is to help people living with upper-body disabilities in their daily life activities. The wireless prototype, the architecture of which is based on a 3-channel sEMG measurement system and a 915-MHz wireless transceiver built around a low-power microcontroller, uses low-cost off-the-shelf commercial components. The embedded controller is compared with JACO's regular joystick-based interface, using combinations of forearm, pectoral, masseter, and trapeze muscles. The measured index of performance values is 0.88, 0.51, and 0.41 bits/s, respectively, for correlation coefficients with the Fitt's model of 0.75, 0.85, and 0.67. These results demonstrate that the proposed controller offers an attractive alternative to conventional interfaces, such as joystick devices, for upper-body disabled people using ATs such as JACO.

  7. Right ventricular longitudinal strain correlates well with right ventricular stroke work index in patients with advanced heart failure referred for heart transplantation.

    Science.gov (United States)

    Cameli, Matteo; Lisi, Matteo; Righini, Francesca Maria; Tsioulpas, Charilaos; Bernazzali, Sonia; Maccherini, Massimo; Sani, Guido; Ballo, Piercarlo; Galderisi, Maurizio; Mondillo, Sergio

    2012-03-01

    Right ventricular (RV) systolic function has a critical role in determining the clinical outcome and success of using left ventricular assist devices (LVADs) in patients with refractory heart failure. Tissue Doppler and M-mode measurements of tricuspid systolic motion (tricuspid S' and tricuspid annular plane systolic excursion [TAPSE]) are the most currently used methods for the quantification of RV longitudinal function; RV deformation analysis by speckle-tracking echocardiography (STE) has recently allowed the analysis of global RV longitudinal function. Using cardiac catheterization as the reference standard, this study aimed at exploring the correlation between RV longitudinal function by STE and RV stroke work index (RVSWI) in patients referred for cardiac transplantation. Right-side heart catheterization and transthoracic echo Doppler were simultaneously performed in 41 patients referred for cardiac transplantation evaluation for advanced systolic heart failure. Thermodilution RV stroke volume and invasive pulmonary pressures were used to obtain RVSWI. RV longitudinal strain (RVLS) by STE was assessed averaging all segments in apical 4-chamber view (global RVLS) and by averaging RV free-wall segments (free-wall RVLS). Tricuspid S' and TAPSE were also calculated. No significant correlations were found for TAPSE or tricuspid S' with RVSWI (r = 0.14; r = 0.06; respectively). Close negative correlations between global RVLS and free-wall RVLS with the RVSWI were found (r = -0.75; r = -0.82; respectively; both P rights reserved.

  8. Integrating medical, assistive, and universally designed products and technologies: assistive technology device classification (ATDC).

    Science.gov (United States)

    Bauer, Stephen; Elsaesser, Linda-Jeanne

    2012-09-01

    ISO26000:2010 International Guidance Standard on Organizational Social Responsibility requires that effective organizational performance recognize social responsibility, including the rights of persons with disabilities (PWD), engage stakeholders and contribute to sustainable development. Millennium Development Goals 2010 notes that the most vulnerable people require special attention, while the World Report on Disability 2011 identifies improved data collection and removal of barriers to rehabilitation as the means to empower PWD. The Assistive Technology Device Classification (ATDC), Assistive Technology Service Method (ATSM) and Matching Person and Technology models provide an evidence-based, standardized, internationally comparable framework to improve data collection and rehabilitation interventions. The ATDC and ATSM encompass and support universal design (UD) principles, and use the language and concepts of the International Classification of Functioning, Disability and Health (ICF). Use ATDC and ICF concepts to differentiate medical, assistive and UD products and technology; relate technology "types" to markets and costs; and support provision of UD products and technologies as sustainable and socially responsible behavior. Supply-side and demand-side incentives are suggested to foster private sector development and commercialization of UD products and technologies. Health and health-related professionals should be knowledgeable of UD principles and interventions.

  9. [Intelligent operating room suite : From passive medical devices to the self-thinking cognitive surgical assistant].

    Science.gov (United States)

    Kenngott, H G; Wagner, M; Preukschas, A A; Müller-Stich, B P

    2016-12-01

    Modern operating room (OR) suites are mostly digitally connected but until now the primary focus was on the presentation, transfer and distribution of images. Device information and processes within the operating theaters are barely considered. Cognitive assistance systems have triggered a fundamental rethinking in the automotive industry as well as in logistics. In principle, tasks in the OR, some of which are highly repetitive, also have great potential to be supported by automated cognitive assistance via a self-thinking system. This includes the coordination of the entire workflow in the perioperative process in both the operating theater and the whole hospital. With corresponding data from hospital information systems, medical devices and appropriate models of the surgical process, intelligent systems could optimize the workflow in the operating theater in the near future and support the surgeon. Preliminary results on the use of device information and automatically controlled OR suites are already available. Such systems include, for example the guidance of laparoscopic camera systems. Nevertheless, cognitive assistance systems that make use of knowledge about patients, processes and other pieces of information to improve surgical treatment are not yet available in the clinical routine but are urgently needed in order to automatically assist the surgeon in situation-related activities and thus substantially improve patient care.

  10. Preparation and Faraday rotation of Bi-YIG/PMMA nanocomposite

    Science.gov (United States)

    Fu, H. P.; Hong, R. Y.; Wu, Y. J.; Di, G. Q.; Xu, B.; Zheng, Y.; Wei, D. G.

    Bismuth-substituted yttrium iron garnet (Bi-YIG) nanoparticles (NPs) were prepared by coprecipitation and subsequent heating treatment. Thermal gravity-differential thermal analysis was performed to investigate the thermal behavior of the Bi-YIG precursors and to decide the best annealing temperature. Phase formation of garnet NPs was investigated by X-ray powder diffraction. The size of Bi-YIG NPs was investigated by transmission electron microscopy, and the magnetic properties of Bi-YIG NPs were measured using a vibrating sample magnetometer. The results show that the temperature needed for the transformation of Bi-YIG from the amorphous phase to the garnet phase decreases with increasing Bi content, and Bi-YIG NPs with sizes of 28-78 nm are obtained after heating treatment at 650-1000 °C. The saturation magnetization of Bi-YIG NPs increases as the Bi content increases. Moreover, the Faraday rotation of polymethyl methacrylate (PMMA) slices doped with Bi-YIG NPs was investigated. The results indicate that the angle of Faraday rotation increases with increasing Bi content in PMMA composites, and the maximum value of the figure of merit is 1.46°, which is comparable to the value of a sputtered film. The Bi-YIG NPs-doped PMMA slices are new promising materials for magneto-optical devices.

  11. Modification of a Volume-Overload Heart Failure Model to Track Myocardial Remodeling and Device-Related Reverse Remodeling

    Science.gov (United States)

    Tuzun, Egemen; Bick, Roger; Kadipasaoglu, Cihan; Conger, Jeffrey L.; Poindexter, Brian J.; Gregoric, Igor D.; Frazier, O. H.; Towbin, Jeffrey A.; Radovancevic, Branislav

    2011-01-01

    Purpose. To provide an ovine model of ventricular remodeling and reverse remodeling by creating congestive heart failure (CHF) and then treating it by implanting a left ventricular assist device (LVAD). Methods. We induced volume-overload heart failure in 2 sheep; 20 weeks later, we implanted an LVAD and assessed recovery 11 weeks thereafter. We examined changes in histologic and hemodynamic data and levels of cellular markers of CHF. Results. After CHF induction, we found increases in LV end-diastolic pressure, LV systolic and diastolic dimensions, wall thickness, left atrial diameter, and atrial natriuretic protein (ANP) and endothelin-1 (ET-1) levels; β-adrenergic receptor (BAR) and dystrophin expression decreased markedly. Biopsies confirmed LV remodeling. After LVAD support, LV systolic and diastolic dimensions, wall thickness, and mass, and ANP and ET-1 levels decreased. Histopathologic and hemodynamic markers improved, and BAR and dystrophin expression normalized. Conclusions. We describe a successful sheep model for ventricular and reverse remodeling. PMID:22347659

  12. Shape Optimization of the Assisted Bi-directional Glenn surgery for stage-1 single ventricle palliation

    Science.gov (United States)

    Verma, Aekaansh; Shang, Jessica; Esmaily-Moghadam, Mahdi; Wong, Kwai; Marsden, Alison

    2016-11-01

    Babies born with a single functional ventricle typically undergo three open-heart surgeries starting as neonates. The first of these stages (BT shunt or Norwood) has the highest mortality rates of the three, approaching 30%. Proceeding directly to a stage-2 Glenn surgery has historically demonstrated inadequate pulmonary flow (PF) & high mortality. Recently, the Assisted Bi-directional Glenn (ABG) was proposed as a promising means to achieve a stable physiology by assisting the PF via an 'ejector pump' from the systemic circulation. We present preliminary parametrization and optimization results for the ABG geometry, with the goal of increasing PF. To limit excessive pressure increases in the Superior Vena Cava (SVC), the SVC pressure is included as a constraint. We use 3-D finite element flow simulations coupled with a single ventricle lumped parameter network to evaluate PF & the pressure constraint. We employ a derivative free optimization method- the Surrogate Management Framework, in conjunction with the OpenDIEL framework to simulate multiple simultaneous evaluations. Results show that nozzle diameter is the most important design parameter affecting ABG performance. The application of these results to patient specific situations will be discussed. This work was supported by an NSF CAREER award (OCI1150184) and by the XSEDE National Computing Resource.

  13. Importance of the atrial channel for ventricular arrhythmia therapy in the dual chamber implantable cardioverter defibrillator.

    Science.gov (United States)

    Dijkman, B; Wellens, H J

    2000-12-01

    Performance of dual chamber implantable cardioverter defibrillator (ICD) systems has been judged based on functioning of the ventricular tachycardia:supraventricular tachycardia (VT:SVT) discrimination criteria and DDD pacing. The purpose of this study was to evaluate the use of dual chamber diagnostics to improve the electrical and antiarrhythmic therapy of ventricular arrhythmias. Information about atrial and ventricular rhythm in relation to ventricular arrhythmia occurrence and therapy was evaluated in 724 spontaneous arrhythmia episodes detected and treated by three types of dual chamber ICDs in 41 patients with structural heart disease. Device programming was based on clinically documented and induced ventricular arrhythmias. In ambulatory patients, sinus tachycardia preceded ventricular arrhythmias more often than in the hospital during exercise testing. The incidence of these VTs could be reduced by increasing the dose of a beta-blocking agent in only two patients. In five patients in whom sinus tachycardia developed after onset of hemodynamic stable VT, propranolol was more effective than Class III antiarrhythmics combined with another beta-blocking agent with regard to the incidence of VT and pace termination. In all but three cases, atrial arrhythmias were present for a longer time before the onset of ventricular arrhythmias. During atrial arrhythmias, fast ventricular rates before the onset of ventricular rate were observed more often than RR irregularities and short-long RR sequences. Dual chamber diagnostics allowed proper interpretation of detection and therapy outcome in patients with different types of ventricular arrhythmia. The advantages of the dual chamber ICD system go further than avoiding the shortcomings of the single chamber system. Information from the atrial chamber allows better device programming and individualization of drug therapy for ventricular arrhythmia.

  14. Light regulated I–V hysteresis loop of Ag/BiFeO{sub 3}/FTO thin film

    Energy Technology Data Exchange (ETDEWEB)

    Wei, Lujun; Sun, Bai; Zhao, Wenxi; Li, Hongwei; Chen, Peng, E-mail: pchen@swu.edu.cn

    2017-01-30

    A hysteresis loop of current–voltage characteristics based multiferroic BiFeO{sub 3} nanoribbons memory device is observed. Moreover, the white-light can greatly regulate both the current–voltage hysteresis loop and the ferroelectric hysteresis loop. The stored space charges within the electrodes/BiFeO{sub 3} interface can lead to hysteresis-type I–V characteristics of Ag/BiFeO{sub 3}/FTO devices. The white-light controlled I–V loop and ferroelectric loop result from photon-generated carries. Since the I–V hysteresis loop and ferroelectric hysteresis loop have a potential application prospect to the memory devices, these two white-light controlled the hysteresis loops curves are likely to provide promising opportunity for developing the multi-functional memory devices.

  15. Physiological Effects of Early Incremental Mobilization of a Patient with Acute Intracerebral and Intraventricular Hemorrhage Requiring Dual External Ventricular Drainage.

    Science.gov (United States)

    Kumble, Sowmya; Zink, Elizabeth K; Burch, Mackenzie; Deluzio, Sandra; Stevens, Robert D; Bahouth, Mona N

    2017-08-01

    Recent trials have challenged the notion that very early mobility benefits patients with acute stroke. It is unclear how cerebral autoregulatory impairments, prevalent in this population, could be affected by mobilization. The safety of mobilizing patients who have external ventricular drainage (EVD) devices for cerebrospinal fluid diversion and intracranial pressure (ICP) monitoring is another concern due to risk of device dislodgment and potential elevation in ICP. We report hemodynamic and ICP responses during progressive, device-assisted mobility interventions performed in a critically ill patient with intracerebral hemorrhage (ICH) requiring two EVDs. A 55-year-old man was admitted to the Neuroscience Critical Care Unit with an acute thalamic ICH and complex intraventricular hemorrhage requiring placement of two EVDs. Progressive mobilization was achieved using mobility technology devices. Range of motion exercises were performed initially, progressing to supine cycle ergometry followed by incremental verticalization using a tilt table. Physiological parameters were recorded before and after the interventions. All mobility interventions were completed without any adverse event or clinically detectable change in the patient's neurological state. Physiological parameters including hemodynamic variables and ICP remained within prescribed goals throughout. Progressive, device-assisted early mobilization was feasible and safe in this critically ill patient with hemorrhagic stroke when titrated by an interdisciplinary team of skilled healthcare professionals. Studies are needed to gain insight into the hemodynamic and neurophysiological responses associated with early mobility in acute stroke to identify subsets of patients who are most likely to benefit from this intervention.

  16. Modeling Users, Context and Devices for Ambient Assisted Living Environments

    Science.gov (United States)

    Castillejo, Eduardo; Almeida, Aitor; López-de-Ipiña, Diego; Chen, Liming

    2014-01-01

    The participation of users within AAL environments is increasing thanks to the capabilities of the current wearable devices. Furthermore, the significance of considering user's preferences, context conditions and device's capabilities help smart environments to personalize services and resources for them. Being aware of different characteristics of the entities participating in these situations is vital for reaching the main goals of the corresponding systems efficiently. To collect different information from these entities, it is necessary to design several formal models which help designers to organize and give some meaning to the gathered data. In this paper, we analyze several literature solutions for modeling users, context and devices considering different approaches in the Ambient Assisted Living domain. Besides, we remark different ongoing standardization works in this area. We also discuss the used techniques, modeled characteristics and the advantages and drawbacks of each approach to finally draw several conclusions about the reviewed works. PMID:24643006

  17. The use of mobile devices as assistive technology in resource-limited environments: access for learners with visual impairments in Kenya.

    Science.gov (United States)

    Foley, Alan R; Masingila, Joanna O

    2015-07-01

    In this paper, the authors explore the use of mobile devices as assistive technology for students with visual impairments in resource-limited environments. This paper provides initial data and analysis from an ongoing project in Kenya using tablet devices to provide access to education and independence for university students with visual impairments in Kenya. The project is a design-based research project in which we have developed and are refining a theoretically grounded intervention--a model for developing communities of practice to support the use of mobile technology as an assistive technology. We are collecting data to assess the efficacy and improve the model as well as inform the literature that has guided the design of the intervention. In examining the impact of the use of mobile devices for the students with visual impairments, we found that the devices provide the students with (a) access to education, (b) the means to participate in everyday life and (c) the opportunity to create a community of practice. Findings from this project suggest that communities of practice are both a viable and a valuable approach for facilitating the diffusion and support of mobile devices as assistive technology for students with visual impairments in resource-limited environments. Implications for Rehabilitation The use of mobile devices as assistive technology in resource-limited environments provides students with visual impairments access to education and enhanced means to participate in everyday life. Communities of practice are both a viable and a valuable approach for facilitating the diffusion and support of mobile devices as assistive technology for students with visual impairments in resource-limited environments. Providing access to assistive technology early and consistently throughout students' schooling builds both their skill and confidence and also demonstrates the capabilities of people with visual impairments to the larger society.

  18. The Syncardia™ total artificial heart: in vivo, in vitro, and computational modeling studies

    Science.gov (United States)

    Slepian, Marvin J.; Alemu, Yared; Soares, João Silva; Smith, Richard G.; Einav, Shmuel; Bluestein, Danny

    2014-01-01

    The SynCardia™ total artificial heart (TAH) is the only FDA-approved TAH in the world. The SynCardia™ TAH is a pneumatically driven, pulsatile system capable of flows of >9 L/min. The TAH is indicated for use as a bridge to transplantation (BTT) in patients at imminent risk of death from non-reversible bi-ventricular failure. In the Pivotal US approval trial the TAH achieved a BTT rate of >79%. Recently a multi-center, post-market approval study similarly demonstrated a comparable BTT rate. A major milestone was recently achieved for the TAH, with over 1100 TAHs having been implanted to date, with the bulk of implantation occurring at an ever increasing rate in the past few years. The TAH is most commonly utilized to save the lives of patients dying from end-stage bi-ventricular heart failure associated with ischemic or non-ischemic dilated cardiomyopathy. Beyond progressive chronic heart failure, the TAH has demonstrated great efficacy in supporting patients with acute irreversible heart failure associated with massive acute myocardial infarction. In recent years several diverse clinical scenarios have also proven to be well served by the TAH including severe heart failure associated with advanced congenital heart disease. failed or burned-out transplants, infiltrative and restrictive cardiomyopathies and failed ventricular assist devices. Looking to the future a major unmet need remains in providing total heart support for children and small adults. As such, the present TAH design must be scaled to fit the smaller patient, while providing equivalent, if not superior flow characteristics, shear profiles and overall device thrombogenicity. To aid in the development of a new “pediatric,” TAH an engineering methodology known as “Device Thrombogenicity Emulation (DTE)”, that we have recently developed and described, is being employed. Recently, to further our engineering understanding of the TAH, as steps towards next generation designs we have: (1

  19. Understanding the C-pulse device and its potential to treat heart failure.

    Science.gov (United States)

    Sales, Virna L; McCarthy, Patrick M

    2010-03-01

    The Sunshine Heart C-Pulse (C-Pulse; Sunshine Heart Inc., Tustin, CA) device is an extra-aortic implantable counterpulsation pump designed as a non-blood contacting ambulatory heart assist device, which may provide relief from symptoms for class II-III congestive heart failure patients. It has a comparable hemodynamic augmentation to intra-aortic balloon counterpulsation devices. The C-Pulse cuff is implanted through a median sternotomy, secured around the ascending aorta, and pneumatically driven by an external system controller. Pre-clinical studies in the acute pig model, and initial temporary clinical studies in patients undergoing off-pump coronary bypass surgery have shown substantial increase in diastolic perfusion of the coronary vessels, which translated to a favorable improvement in ventricular function. A U.S. prospective multi-center trial to evaluate the safety and efficacy of the C-Pulse in class III patients with moderate heart failure is now in progress.

  20. Effects of Percutaneous LVAD Support on Right Ventricular Load and Adaptation.

    Science.gov (United States)

    Yourshaw, Jeffrey P; Mishra, Prabodh; Armstrong, M Christopher; Ramu, Bhavadharini; Craig, Michael L; Van Bakel, Adrian B; Steinberg, Daniel H; DiSalvo, Thomas G; Tedford, Ryan J; Houston, Brian A

    2018-04-30

    Both operative and hemodynamic mechanisms have been implicated in right heart failure (RHF) following surgical left ventricular assist device (LVAD) implantation. We investigated the effects of percutaneous LVAD (pLVAD; Impella®, Abiomed) support on right ventricular (RV) load and adaptation. We reviewed all patients receiving a pLVAD for cardiogenic shock at our institution between July 2014 and April 2017, including only those with pre- and post-pLVAD invasive hemodynamic measurements. Hemodynamic data was recorded immediately prior to pLVAD implantation and up to 96 h post-implantation. Twenty-five patients were included. Cardiac output increased progressively during pLVAD support. PAWP improved early post-pLVAD but did not further improve during continued support. Markers of RV adaptation (right ventricular stroke work index, right atrial pressure (RAP), and RAP to pulmonary artery wedge pressure ratio (RAP:PAWP)) were unchanged acutely implant but progressively improved during continued pLVAD support. Total RV load (pulmonary effective arterial elastance; E A ) and resistive RV load (pulmonary vascular resistance; PVR) both declined progressively. The relationship between RV load and RV adaptation (E A /RAP and E A /RAP:PAWP) was constant throughout. Median vasoactive-inotrope score declined after pLVAD placement and continued to decline throughout support. Percutaneous LVAD support in patients with cardiogenic shock did not acutely worsen RV adaptation, in contrast to previously described hemodynamic effects of surgically implanted durable LVADs. Further, RV load progressively declined during support, and the noted RV adaptation improvement was load-dependent as depicted by constant E A /RA and E A /RAP:PAWP relationships. These findings further implicate the operative changes associated with surgical LVAD implantation in early RHF following durable LVAD.

  1. Falls and Use of Assistive Devices in Stroke Patients with Hemiparesis: Association with Balance Ability and Fall Efficacy.

    Science.gov (United States)

    Kim, Oksoo; Kim, Jung-Hee

    2015-01-01

    This study investigates balance ability and the fall efficacy with regard to the experiences of stroke patients with hemiparesis. The experience of falling, the use of assistive devices, and each disease-related characteristic were assessed using face-to-face interviews and a self-reported questionnaire. The Berg Balance Scale and Fall Efficacy Scale were used to measure balance ability and confidence. The fall efficacy was significantly lower in participants who had experienced falls than those who had not. The participants who used assistive devices exhibited low balance ability and fall efficacy compared to those who did not use assistive devices. Stroke patients with fall experience and walking aids might be considered at increased risk of falling. Preventive measures for individuals using walking aids may be beneficial in reducing the fall rate of community-dwelling stroke patients. © 2014 Association of Rehabilitation Nurses.

  2. Transcatheter device closure of perimembranous ventricular septal defect in children treated with prophylactic oral steroids: acute and mid-term results of a single-centre, prospective, observational study.

    Science.gov (United States)

    Thakkar, Bhavesh; Patel, Nehal; Bohora, Shomu; Bhalodiya, Dharmin; Singh, Tarandeep; Madan, Tarun; Shah, Saurin; Poptani, Vishal; Shukla, Anand

    2016-04-01

    Background and Objective Although transcatheter closure of perimembranous ventricular septal defect is emerging as an accepted, viable alternative, conduction disturbances still remain a major concern. Although steroid treatment has shown encouraging results with complete recovery, efficacy of prophylactic use of steroids is still speculative. We aim to study the mid-term outcome of perimembranous ventricular septal defect closure in children who received prophylactic oral steroids. Materials and methods A prospective study was designed and antegrade device closure was attempted in eligible children who met the following inclusion criteria: age 3-18 years and weight >10 kg, defect diameter ⩽12 mm, and symptomatic, haemodynamic changes or history of infective endocarditis. Prophylactic steroid protocol consisted of 2 weeks oral prednisolone (1 mg/kg/day) initiated immediately after the procedure, and in the event of bradyarrhythmia it was escalated to 2 mg/kg. Patients were regularly followed-up at 1, 6, and 12 months and then annually. Patients with post-procedure heart block underwent Holter monitoring after a minimum of 1 year interval. Between May, 2007 and August, 2012, successful device closure was accomplished in 290/297 patients. Mean age and weight were 9±3.12 years and 21±8.27 kg, respectively. The defect measured 5±1.38 mm on echocardiography. Mean fluoroscopy time was 12.98±8.64 minutes. Eight patients with major complications included one each with device embolisation, haemolysis, severe aortic regurgitation, and five with bradyarrhythmias, including complete atrioventricular block in three, Mobitz II in one, and bifascicular block in one. Patients with complete atrioventricular block responded to high-dose steroid and temporary pacemaker. Minor complications included post-procedure heart block (n=22) and blood loss (n=2). At 18.23±13.15 months follow-up, 8/27 (five major, 22 minor) with arrhythmia had persistent post-procedure heart block of no

  3. The effect of acute mechanical left ventricular unloading on ovine tricuspid annular size and geometry.

    Science.gov (United States)

    Malinowski, Marcin; Wilton, Penny; Khaghani, Asghar; Brown, Michael; Langholz, David; Hooker, Victoria; Eberhart, Lenora; Hooker, Robert L; Timek, Tomasz A

    2016-09-01

    Left ventricular assist device (LVAD) implantation may alter right ventricular shape and function and lead to tricuspid regurgitation. This in turn has been reported to be a determinant of right ventricular (RV) failure after LVAD implantation, but the effect of mechanical left ventricular (LV) unloading on the tricuspid annulus is unknown. The aim of the study was to provide insight into the effect of LVAD support on tricuspid annular geometry and dynamics that may help to optimize LV unloading with the least deleterious effect on the right-sided geometry. In seven open-chest anaesthetized sheep, nine sonomicrometry crystals were implanted on the right ventricle. Additional nine crystals were implanted around the tricuspid annulus, with one crystal at each commissure defining three separate annular regions: anterior, posterior and septal. Left ventricular unloading was achieved by connecting a cannula in the left atrium and the aorta to a continuous-flow pump. The pump was used for 15 min at a full flow of 3.8 ± 0.3 l/min. Epicardial echocardiography was used to assess the degree of tricuspid insufficiency. Haemodynamic, echocardiographic and sonomicrometry data were collected before and during full unloading. Tricuspid annular area, and the regional and total perimeter were calculated from crystal coordinates, while 3D annular geometry was expressed as the orthogonal distance of each annular crystal to the least squares plane of all annular crystals. There was no significant tricuspid regurgitation observed either before or during LV unloading. Right ventricular free wall to septum diameter increased significantly at end-diastole during unloading from 23.6 ± 5.8 to 26.3 ± 6.5 mm (P = 0.009), but the right ventricular volume, tricuspid annular area and total perimeter did not change from baseline. However, the septal part of the annulus significantly decreased its maximal length (38.6 ± 8.1 to 37.9 ± 8.2 mm, P = 0.03). Annular contraction was not altered. The

  4. Multistate storage nonvolatile memory device based on ferroelectricity and resistive switching effects of SrBi2Ta2O9 films

    Science.gov (United States)

    Song, Zhiwei; Li, Gang; Xiong, Ying; Cheng, Chuanpin; Zhang, Wanli; Tang, Minghua; Li, Zheng; He, Jiangheng

    2018-05-01

    A memory device with a Pt/SrBi2Ta2O9(SBT)/Pt(111) structure was shown to have excellent combined ferroelectricity and resistive switching properties, leading to higher multistate storage memory capacity in contrast to ferroelectric memory devices. In this device, SBT polycrystalline thin films with significant (115) orientation were fabricated on Pt(111)/Ti/SiO2/Si(100) substrates using CVD (chemical vapor deposition) method. Measurement results of the electric properties exhibit reproducible and reliable ferroelectricity switching behavior and bipolar resistive switching effects (BRS) without an electroforming process. The ON/OFF ratio of the resistive switching was found to be about 103. Switching mechanisms for the low resistance state (LRS) and high resistance state (HRS) currents are likely attributed to the Ohmic and space charge-limited current (SCLC) behavior, respectively. Moreover, the ferroelectricity and resistive switching effects were found to be mutually independent, and the four logic states were obtained by controlling the periodic sweeping voltage. This work holds great promise for nonvolatile multistate memory devices with high capacity and low cost.

  5. Prediction of left ventricular dysfunction after device closure of patent ductus arteriosus: proposal for a new functional classification.

    Science.gov (United States)

    Kiran, Viralam S; Tiwari, Ashish

    2018-04-06

    The aims of this study were to determine the incidence and correlates of left ventricular (LV) dysfunction amongst percutaneous patent ductus arteriosus (PDA) device closure patients, and to propose an indexed parameter for predicting LV dysfunction. In a retrospective cross-sectional analysis of 30 months duration, 447 patients who underwent PDA device closure were studied. The diameter of the PDA at the pulmonary artery end was measured in the angiograms in all patients and was indexed for their body surface area. The indexed PDA size was categorised into group A (1-2.9 mm/m², 35/447), B (3-5.9 mm/m², 254/447), C (6-8.9 mm/m², 66/447) and D (>9 mm/m², 35/447). Systolic LV function was evaluated using echocardiography at frequent intervals. Overall, 62.63% of the patients were female (280/447). At baseline, all 447 patients had normal LV function. LV dysfunction was seen in 102/447 (22.8%) patients with 2.8% in category A (1/35), 10.6% in category B (27/254), 34.1% in category C (42/123) and 91.4% in category D (32/35) after PDA device closure. Correlation of indexed PDA size and LV dysfunction was statistically significant (pclosures. Indexed PDA size correlates well with post-procedural LV dysfunction. The authors propose a new classification of PDA utilising this accurate, reproducible and easy to perform parameter, which does not involve any extra cost, for risk stratification and early management in device closure of PDA.

  6. Embodying prostheses - how to let the body welcome assistive devices. Comment on "The embodiment of assistive devices-from wheelchair to exoskeleton" by M. Pazzaglia and M. Molinari

    Science.gov (United States)

    Longo, Matthew R.; Sadibolova, Renata; Tamè, Luigi

    2016-03-01

    A growing body of research has focused on the development of assistive devises to improve the recovery and ameliorate the quality of life of people suffering from spinal cord injuries (SCI). In their stimulating and timely paper, Pazzaglia and Molinari [1] review the significant progress made by biotechnology studies in providing increasing sophisticated assistive tools (e.g., prostheses and exoskeletons) that extend the functionality of patients' bodies. However, despite this extraordinary technological effort [2], it remains uncertain how these devices can be appropriately embedded into the mental representation of the body. Here, we wish to amplify the points raised by Pazzaglia and Molinari by discussing three challenges facing work on embodying prostheses raised by experimental research on body representation.

  7. On atomic mechanisms governing the oxidation of Bi2Te3

    Science.gov (United States)

    Music, Denis; Chang, Keke; Schmidt, Paul; Braun, Felix N.; Heller, Martin; Hermsen, Steffen; Pöllmann, Peter J.; Schulzendorff, Till; Wagner, Cedric

    2017-12-01

    Oxidation of Bi2Te3 (space group R \\overline{3} m) has been investigated using experimental and theoretical means. Based on calorimetry, x-ray photoelectron spectroscopy and thermodynamic modelling, Bi2Te3 is at equilibrium with Bi2O3 and TeO2, whereby the most stable compound is Bi2Te3, followed by Bi2O3. The reactivity of Bi towards oxygen is expected to be higher than that of Te. This notion is supported by density functional theory. The strongest bond is formed between Bi and Te, followed by Bi-O. This gives rise to unanticipated atomic processes. Dissociatively adsorbed oxygen diffuses through Bi and Te basal planes of Bi2Te3(0 0 0 1) and preferably interacts with Bi. The Te termination considerably retards this process. These findings may clarify conflicting literature data. Any basal plane off-cut or Bi terminations trigger oxidation, but a perfect basal cleavage, where only Te terminations are exposed to air, may be stable for a longer period of time. These results are of relevance for applications in which surfaces are of key importance, such as nanostructured Bi2Te3 thermoelectric devices.

  8. Ventricular arrhythmias and sudden cardiac arrest in Takotsubo cardiomyopathy: Incidence, predictive factors, and clinical implications.

    Science.gov (United States)

    Jesel, Laurence; Berthon, Charlotte; Messas, Nathan; Lim, Han S; Girardey, Mélanie; Marzak, Halim; Marchandot, Benjamin; Trinh, Annie; Ohlmann, Patrick; Morel, Olivier

    2018-04-06

    Takotsubo cardiomyopathy (TTC) is a stress-related transient cardiomyopathy. Life-threatening arrhythmias (LTA) can occur and worsen prognosis. The purpose of this study was to assess the incidence and outcome of LTA in TTC, as well as its predictive factors and clinical implications. We studied 214 consecutive cases of TTC over 8 years. The study cohort was divided into 2 groups: those with LTA (LTA group) and those without (non-LTA group). LTA was defined as ventricular tachycardia, ventricular fibrillation, or cardiac arrest. LTA occurred in 10.7% of patients mainly in the first 24 hours of hospitalization: ventricular tachycardia (n = 2), ventricular fibrillation (n = 11), cardiac arrest (n = 10: 5 asystole, 3 complete heart block, and 2 sinoatrial block). LTA were associated with lower left ventricular ejection fraction (LVEF) and a high rate of conduction disturbances. In-hospital (39.1% vs 8.9%; P 105 ms were independent predictors of LTA. In cases where a device was implanted, conduction disturbances persisted after the index event despite complete recovery of LVEF. There was no ventricular arrhythmia recurrence during follow-up. LTA occur early in patients presenting with TTC and is associated with significantly worse short- and long-term prognosis. Left ventricular impairment and QRS duration >105 ms are independent predictors of LTA. Ventricular arrhythmias occurred in the acute phase without further recurrence recorded in hospital survivors, whereas severe conduction disorders persisted during long-term follow-up. These findings may have implications on the choice of device therapy for this specific patient subgroup. Copyright © 2018 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  9. Internal vacuum-assisted closure device in the swine model of severe liver injury

    Directory of Open Access Journals (Sweden)

    Everett Christopher B

    2012-12-01

    Full Text Available Abstract Objectives The authors present a novel approach to nonresectional therapy in major hepatic trauma utilizing intraabdominal perihepatic vacuum assisted closure (VAC therapy in the porcine model of Grade V liver injury. Methods A Grade V injury was created in the right lobe of the liver in a healthy pig. A Pringle maneuver was applied (4.5 minutes total clamp time and a vacuum assisted closure device was placed over the injured lobe and connected to suction. The device consisted of a perforated plastic bag placed over the liver, followed by a 15 cm by 15cm VAC sponge covered with a nonperforated plastic bag. The abdomen was closed temporarily. Blood loss, cardiopulmonary parameters and bladder pressures were measured over a one-hour period. The device was then removed and the animal was euthanized. Results Feasibility of device placement was demonstrated by maintenance of adequate vacuum suction pressures and seal. VAC placement presented no major technical challenges. Successful control of ongoing liver hemorrhage was achieved with the VAC. Total blood loss was 625 ml (20ml/kg. This corresponds to class II hemorrhagic shock in humans and compares favorably to previously reported estimated blood losses with similar grade liver injuries in the swine model. No post-injury cardiopulmonary compromise or elevated abdominal compartment pressures were encountered, while hepatic parenchymal perfusion was maintained. Conclusion These data demonstrate the feasibility and utility of a perihepatic negative pressure device for the treatment of hemorrhage from severe liver injury in the porcine model.

  10. Higher critical current density achieved in Bi-2223 High-Tc superconductors

    Directory of Open Access Journals (Sweden)

    M.S. Shalaby

    2016-07-01

    Full Text Available Bi2Sr2Ca2Cu3Ox (Bi-2223 were prepared using a solid state reaction method at different sintering times and temperatures. Structural phase identifications have been done using X-Ray analysis and refinement by Reitveld method which proves the coexistence of Bi-2223 and Bi-2212 phases. The critical transition temperature Tc and critical current density Jc values were measured using superconducting quantum interference device magnetometer (SQUID and by the magneto-optics technique. A remarkable rapid decrease to the diamagnetic signal in the magnetization versus temperature M(T at 110 K and Jc around 1.2 × 107 A/m2 at 5 K are confirmed for the Bi-2223 compound.

  11. Lung assist devices influence cardio-energetic parameters: Numerical simulation study.

    Science.gov (United States)

    De Lazzari, C; Quatember, B; Recheis, W; Mayr, M; Demertzis, S; Allasia, G; De Rossi, A; Cavoretto, R; Venturino, E; Genuini, I

    2015-08-01

    We aim at an analysis of the effects mechanical ventilators (MVs) and thoracic artificial lungs (TALs) will have on the cardiovascular system, especially on important quantities, such as left and right ventricular external work (EW), pressure-volume area (PVA) and cardiac mechanical efficiency (CME). Our analyses are based on simulation studies which were carried out by using our CARDIOSIM(©) software simulator. At first, we carried out simulation studies of patients undergoing mechanical ventilation (MV) without a thoracic artificial lung (TAL). Subsequently, we conducted simulation studies of patients who had been provided with a TAL, but did not undergo MV. We aimed at describing the patient's physiological characteristics and their variations with time, such as EW, PVA, CME, cardiac output (CO) and mean pulmonary arterial/venous pressure (PAP/PVP). We were starting with a simulation run under well-defined initial conditions which was followed by simulation runs for a wide range of mean intrathoracic pressure settings. Our simulations of MV without TAL showed that for mean intrathoracic pressure settings from negative (-4 mmHg) to positive (+5 mmHg) values, the left and right ventricular EW and PVA, right ventricular CME and CO decreased, whereas left ventricular CME and the PAP increased. The simulation studies of patients with a TAL, comprised all the usual TAL arrangements, viz. configurations "in series" and in parallel with the natural lung and, moreover, hybrid configurations. The main objective of the simulation studies was, as before, the assessment of the hemodynamic response to the application of a TAL. We could for instance show that, in case of an "in series" configuration, a reduction (an increase) in left (right) ventricular EW and PVA values occurred, whereas the best performance in terms of CO can be achieved in the case of an in parallel configuration.

  12. Magnetic force driven magnetoelectric effect in bi-cantilever composites

    Science.gov (United States)

    Zhang, Ru; Wu, Gaojian; Zhang, Ning

    2017-12-01

    The magnetic force driven magnetoelectric (ME) effect in bi-cantilever Mn-Zn-Ferrite /PZT composites is presented. Compared with single cantilever, the ME voltage coefficient in bi-cantilever composite is a little lower and the resonance frequency is higher, but the bi-cantilever structure is advantageous for integration. When the magnetic gap is 3 mm, the ME voltage coefficient can achieve 6.2 Vcm-1Oe-1 at resonance under optimum bias field Hm=1030 Oe; when the magnetic gap is 1.5 mm, the ME voltage coefficient can get the value as high as 4.4 Vcm-1Oe-1 under much lower bias field H=340 Oe. The stable ME effect in bi-cantilever composites has important potential application in the design of new type ME device.

  13. Assistive devices alter gait patterns in Parkinson disease: advantages of the four-wheeled walker.

    Science.gov (United States)

    Kegelmeyer, Deb A; Parthasarathy, Sowmya; Kostyk, Sandra K; White, Susan E; Kloos, Anne D

    2013-05-01

    Gait abnormalities are a hallmark of Parkinson's disease (PD) and contribute to fall risk. Therapy and exercise are often encouraged to increase mobility and decrease falls. As disease symptoms progress, assistive devices are often prescribed. There are no guidelines for choosing appropriate ambulatory devices. This unique study systematically examined the impact of a broad range of assistive devices on gait measures during walking in both a straight path and around obstacles in individuals with PD. Quantitative gait measures, including velocity, stride length, percent swing and double support time, and coefficients of variation were assessed in 27 individuals with PD with or without one of six different devices including canes, standard and wheeled walkers (two, four or U-Step). Data were collected using the GAITRite and on a figure-of-eight course. All devices, with the exception of four-wheeled and U-Step walkers significantly decreased gait velocity. The four-wheeled walker resulted in less variability in gait measures and had less impact on spontaneous unassisted gait patterns. The U-Step walker exhibited the highest variability across all parameters followed by the two-wheeled and standard walkers. Higher variability has been correlated with increased falls. Though subjects performed better on a figure-of-eight course using either the four-wheeled or the U-Step walker, the four-wheeled walker resulted in the most consistent improvement in overall gait variables. Laser light use on a U-Step walker did not improve gait measures or safety in figure-of-eight compared to other devices. Of the devices tested, the four-wheeled-walker offered the most consistent advantages for improving mobility and safety. Copyright © 2012 Elsevier B.V. All rights reserved.

  14. Subjective and objective outcomes from new BiCROS technology in a veteran sample.

    Science.gov (United States)

    Williams, Victoria A; McArdle, Rachel A; Chisolm, Theresa H

    2012-01-01

    Patients with single-sided deafness (SSD), where one ear has an unaidable hearing loss and the other ear has normal or aidable hearing, often complain of difficulties understanding speech and localizing sound sources, and report a higher self-perceived hearing disability. Patients with SSD may benefit from using contralateral routing of signal (CROS) or bilateral contralateral routing of the signal (BiCROS) amplification. Dissatisfaction of previously available (Bi)CROS devices has been reported, such as, interfering transmissions, low-fidelity sound quality, poor "user-friendly" set-up, and a bulky and cosmetically cumbersome appearance. Recent advances in hearing aid technology have improved (Bi)CROS hearing aids; however, these devices have not been experimentally evaluated. We hypothesized that newer technology with reports of improved digital signal processing, wireless transmission, and physical design would be as good, or better than, our participants' previous-generation BiCROS systems. A within-subjects, pretest-posttest design was executed. Thirty-nine veterans (one female, 38 males; mean age = 74 yr, range = 49-85 yr) from the Audiology Section of the Bay Pines Veterans Affair Healthcare System participated. All participants were previously experienced BiCROS hearing aid users with varying degrees of sensorinerual hearing impairment in their better ear. Participants were provided at least 4 wk of consistent use with the new BiCROS. DATA COLLECTION AND ANALYSES: Participants completed three research visits. At Visit 1, with their previous BiCROS, and at Visit 3, with their new BiCROS, the following objective and subjective measures were obtained: (1) soundfield speech-in-noise testing using the Words-In-Noise (WIN) test; (2) speech, spatial, and qualities of the hearing scale (SSQ) questionnaire; (3) selected questions from the MarkeTrak questionnaire; and, (4) three open-ended questions. Data were analyzed using parametric and nonparametric statistics

  15. Quantum spin Hall insulator BiXH (XH = OH, SH) monolayers with a large bulk band gap.

    Science.gov (United States)

    Hu, Xing-Kai; Lyu, Ji-Kai; Zhang, Chang-Wen; Wang, Pei-Ji; Ji, Wei-Xiao; Li, Ping

    2018-05-16

    A large bulk band gap is critical for the application of two-dimensional topological insulators (TIs) in spintronic devices operating at room temperature. On the basis of first-principles calculations, we predict BiXH (X = OH, SH) monolayers as TIs with an extraordinarily large bulk gap of 820 meV for BiOH and 850 meV for BiSH, and propose a tight-binding model considering spin-orbit coupling to describe the electronic properties of BiXH. These large gaps are entirely due to the strong spin-orbit interaction related to the pxy orbitals of the Bi atoms of the honeycomb lattice. The orbital filtering mechanism can be used to understand the topological properties of BiXH. The XH groups simply remove one branch of orbitals (pz of Bi) and reduce the trivial 6-band lattice into a 4-band, which is topologically non-trivial. The topological characteristics of BiXH monolayers are confirmed by nonzero topological invariant Z2 and a single pair of gapless helical edge states in the bulk gap. Owing to these features, the BiXH monolayers of the large-gap TIs are an ideal platform to realize many exotic phenomena and fabricate new quantum devices working at room temperature.

  16. Layer structured bismuth selenides Bi2Se3 and Bi3Se4 for high energy and flexible all-solid-state micro-supercapacitors

    Science.gov (United States)

    Hao, Chunxue; Wang, Lidan; Wen, Fusheng; Xiang, Jianyong; Li, Lei; Hu, Wentao; Liu, Zhongyuan

    2018-02-01

    In this work, bismuth selenides (Bi2Se3 and Bi3Se4), both of which have a layered rhombohedral crystal structure, have been found to be useful as electrode materials for supercapacitor applications. In a liquid electrolyte system (6M KOH), Bi2Se3 nanoplates exhibit much better performance as an electrode material than Bi3Se4 nanoparticles do, delivering a higher specific capacitance (272.9 F g-1) than that of Bi3Se4 (193.6 F g-1) at 5 mV s-1. This result may be attributed to the fact that Bi2Se3 nanoplates possess more active electrochemical surfaces for the reversible surface redox reactions owing to their planar quintuple stacked layers (septuple layers for Bi3Se4). To meet the demands of electronic skin, we used a novel flexible annular interdigital structure electrode to support the all-solid-state micro-supercapacitors (AMSCs). The Bi2Se3 AMSC device delivers a much better supercapacitor performance, exhibits a large stack capacitance of 89.5 F cm-3 at 20 mV s-1 (Bi3Se4: 79.1 F cm-3), a high energy density of 17.9 mWh cm-3 and a high power density of 18.9 W cm-3. The bismuth selenides also exhibit good cycle stability, with 95.5% retention after 1000 c for Bi2Se3 (Bi3Se4:90.3%). Clearly, Bi2Se3 nanoplates can be promising electrode materials for flexible annular interdigital AMSCs.

  17. Development of a fixation device for robot assisted fracture reduction of femoral shaft fractures: a biomechanical study.

    Science.gov (United States)

    Weber-Spickschen, T S; Oszwald, M; Westphal, R; Krettek, C; Wahl, F; Gosling, T

    2010-01-01

    Robot assisted fracture reduction of femoral shaft fractures provides precise alignment while reducing the amount of intraoperative imaging. The connection between the robot and the fracture fragment should allow conventional intramedullary nailing, be minimally invasive and provide interim fracture stability. In our study we tested three different reduction tools: a conventional External Fixator, a Reposition-Plate and a Three-Point-Device with two variations (a 40 degrees and a 90 degrees version). We measured relative movements between the tools and the bone fragments in all translation and rotation planes. The Three-Point-Device 90 degrees showed the smallest average relative displacement and was the only device able to withstand the maximum applied load of 70 Nm without failure of any bone fragment. The Three-Point-Device 90 degrees complies with all the stipulated requirements and is a suitable interface for robot assisted fracture reduction of femoral shaft fractures.

  18. A Numerical Analysis of Phononic-Assisted Control of Ultrasound Waves in Acoustofluidic Device

    DEFF Research Database (Denmark)

    Moiseyenko, Rayisa; Bruus, Henrik

    2015-01-01

    and streaming has received much attention, since it relies solely on mechanical properties such as particle size and contrast in density and compressibility. We present a theoretical study of phononic-assisted control of ultrasound waves in acoustofluidic devices. We propose the use of phononic crystal...... diffractors, which can be introduced in acoustofluidic structures. These diffractors can be applied in the design of efficient resonant cavities, directional sound waves for new types of particle sorting methods, or acoustically controlled deterministic lateral displacement. The PnC-diffractor-based devices...... can be made configurable, by embedding the diffractors, all working at the same excitation frequency but with different resulting diffraction patterns, in exchangeable membranes on top of the device....

  19. Loose-Lipped Mobile Device Intelligent Personal Assistants: A Discussion of Information Gleaned from Siri on Locked iOS Devices.

    Science.gov (United States)

    Horsman, Graeme

    2018-04-23

    The forensic analysis of mobile handsets is becoming a more prominent factor in many criminal investigations. Despite such devices frequently storing relevant evidential content to support an investigation, accessing this information is becoming an increasingly difficult task due to enhanced effective security features. Where access to a device's resident data is not possible via traditional mobile forensic methods, in some cases it may still be possible to extract user information via queries made to an installed intelligent personal assistant. This article presents an evaluation of the information which is retrievable from Apple's Siri when interacted with on a locked iOS device running iOS 11.2.5 (the latest at the time of testing). The testing of verbal commands designed to elicit a response from Siri demonstrate the ability to recover call log, SMS, Contacts, Apple Maps, Calendar, and device information which may support any further investigation. © 2018 American Academy of Forensic Sciences.

  20. X-ray standing wave study of the Bi/GaAs and Bi/GaP interfaces

    International Nuclear Information System (INIS)

    Herrera-Gomez, A.

    1994-04-01

    Interfaces are one of the most important elements determining the characteristics of electronic devices. Composite semiconductors, specifically the III-V family, are technologically attractive because of their mobility and optical properties, and also because they offer the possibility of engineering such properties as the size of the band gap. Nevertheless, Si has remained the most utilized semiconductor material, primarily because the fabrication of practical MOSFETs with III-V semiconductors remains elusive. Examples of such complex interfaces are the structures formed by one monolayer of Bi on the (110) surface of GaAs and GaP. While better matched Column V elements form epitaxial continuous monolayers on III-V semiconductor (110) surfaces, Bi is too large to accommodate on GaAs and GaP surfaces with long range order, and vacancies appear to allow relaxation. For the ideal systems, symmetry imposes the presence of only two nonequivalent adatom sites. However, for Bi/GaAs and Bi/GaP, more than two different sites are present because the position of Bi atoms next to a vacancy is not necessarily equivalent to that between other Bi atoms. The geometry of the Bi/GaAs and Bi/GaP systems was determined here by triangulating XSW results from three Bragg planes. A methodology was developed that provides an intrinsic check of the validity of assuming two sites for the overlayer structures. An experimental method was developed that allows the three reflections to be measured on the same sample, thus reducing the number of experimental variables, such as the degree of disorder. The traditional method of analysis was not accurate enough for this data, so a more reliable and faster method of data fitting was developed. A configuration used in the present work, which previously has been widely used, presents an intrinsic multireflection problem. This issue is discussed in depth, and the appropriate method is determined for analyzing the data obtained with this configuration

  1. Surgical ablation of ventricular tachycardia secondary to congenital ventricular septal aneurysm.

    Science.gov (United States)

    Graffigna, A; Minzioni, G; Ressia, L; Vigano, M

    1994-04-01

    Three patients underwent surgical ablation for ventricular tachycardia resulting from an aneurysm of the membranous portion of the ventricular septum. Two patients had a definite history of cardiac murmur during infancy, and one of them was found at the time of operation to have a left-to-right shunt through the apex of the aneurysm. The earliest ventricular activation sites were located around the neck of the aneurysm and were ablated in 1 patient by encircling the endocardial ventriculotomy and by cryoablation in the remaining 2. After focus resection had been completed, aneurysm resection and ventricular septal reconstruction were performed. All patients were alive and free of ventricular tachycardia and did not need medication as of 61, 66, and 88 months postoperatively. Spontaneous closure of a ventricular septal defect may lead to the formation of an aneurysm in the ventricular septum that may sustain ventricular tachycardias. Such arrhythmias can be effectively treated using electrically guided surgical techniques.

  2. Annealing effect on the bipolar resistive switching behaviors of BiFeO3 thin films on LaNiO3-buffered Si substrates

    International Nuclear Information System (INIS)

    Chen Xinman; Zhang Hu; Ruan Kaibin; Shi Wangzhou

    2012-01-01

    Highlights: ► Annealing effect on the bipolar resistive switching behaviors of BiFeO 3 thin films with Pt/BiFeO 3 /LNO was reported. ► Rectification property was explained from the asymmetrical contact between top and bottom interfaces and the distinct oxygen vacancy density. ► The modification of Schottky-like barrier was suggested to be responsible for the resistance switching behaviors of Pt/BiFeO 3 /LNO devices. - Abstract: We reported the annealing effect on the electrical behaviors of BiFeO 3 thin films integrated on LaNiO 3 (LNO) layers buffered Si substrates by sol–gel spin-coating technique. All the BiFeO 3 thin films exhibit the reversible bipolar resistive switching behaviors with Pt/BiFeO 3 /LNO configuration. The electrical conduction mechanism of the devices was dominated by the Ohmic conduction in the low resistance state and trap-controlled space charged limited current in the high resistance state. Good diode-like rectification property was observed in device with BiFeO 3 film annealed at 500 °C, but vanished in device with BiFeO 3 film annealed at 600 °C. This was attributed to the asymmetrical contact between top and bottom interfaces as well as the distinct oxygen vacancy density verified by XPS. Furthermore, the modification of Schottky-like barrier due to the drift of oxygen vacancies was suggested to be responsible for the resistance switching behaviors of Pt/BiFeO 3 /LNO devices.

  3. Quantum confinement of Bi2S3 in glass with magnetic behavior

    Directory of Open Access Journals (Sweden)

    Rajendra P. Panmand

    2013-02-01

    Full Text Available The novel Bi2S3 quantum dots (QDs glass nanosystems with unique magnetic properties have been investigated. The monodispersed QDs of size in the range of 3 to 15 nm were grown in the glass matrix. The optical study of these nanosystems clearly demonstrated the size quantization effect resulting in a pronounced band gap variation with QD size. The magnetic properties of the pristine glass and the Bi2S3 QD glass nanosystems were investigated by VSM and SQUID magnetometer. The pristine glass did not show any ferromagnetism while the Bi2S3 glass nanosystems showed significant and reproducible ferromagnetism. We also investigated the effect of the size of Bi2S3 QDs on the magnetic properties. The saturation magnetization for the 15 nm QD glass-nanosystem (124 memu/g was observed to be higher as compared to the 3nm QD glass nanosystem (58.2 memu/g. The SQUID measurement gave the excellent hysteresis up to 300K. Surprisingly, the bulk Bi2S3 powder is diamagnetic in nature but Bi2S3 quantum dots glass nanosystem showed the ferromagnetic behavior for the first time. The investigated novel QD glass-nanosystem may have a potential application in spintronic devices and most importantly, this nanosystem can be fabricated in any usable shape as per the device requirement.

  4. LaBiTe3: An unusual thermoelectric material

    KAUST Repository

    Singh, Nirpendra

    2014-06-18

    Using first-principles calculations and semi-classical Boltzmann transport theory, the thermoelectric properties of LaBiTe3 are studied. The band gap and, hence, the thermoelectric response are found to be easily tailored by application of strain. Independent of the temperature, the figure of merit turns out to be maximal at a doping of about 1.6 × 1021 cm-3. At room temperature we obtain values of 0.4 and 0.5 for unstrained and moderately strained LaBiTe3, which increases to 1.1 and 1.3 at 800 K. A large spin splitting is observed in the conduction band at the T point. Therefore, LaBiTe3 merges characteristics that are interesting for thermoelectric as well as spintronic devices.

  5. LaBiTe3: An unusual thermoelectric material

    KAUST Repository

    Singh, Nirpendra; Schwingenschlö gl, Udo

    2014-01-01

    Using first-principles calculations and semi-classical Boltzmann transport theory, the thermoelectric properties of LaBiTe3 are studied. The band gap and, hence, the thermoelectric response are found to be easily tailored by application of strain. Independent of the temperature, the figure of merit turns out to be maximal at a doping of about 1.6 × 1021 cm-3. At room temperature we obtain values of 0.4 and 0.5 for unstrained and moderately strained LaBiTe3, which increases to 1.1 and 1.3 at 800 K. A large spin splitting is observed in the conduction band at the T point. Therefore, LaBiTe3 merges characteristics that are interesting for thermoelectric as well as spintronic devices.

  6. Laparoscopy-assisted percutaneous endoscopic gastrostomy using a "Funada-kit II" device.

    Science.gov (United States)

    Takahashi, Toshiaki; Miyano, Go; Shiyanagi, Satoko; Lane, Geoffrey J; Yamataka, Atsuyuki

    2012-09-01

    We aimed at assessing the effect of using a "Funada-kit II" device during laparoscopy-assisted percutaneous endoscopic gastrostomy (Lap-PEG), by reviewing 29 cases of Lap-PEG we performed from 2001 to 2011. We started using the "Funada-kit II" (CREATE MEDIC CO., Kanagawa, Japan) device with two parallel needles to puncture the stomach and assist suturing the anterior gastric wall to the anterior abdominal wall during Lap-PEG in 2011 (F-PEG). By introducing a loop through the lumen of one needle which allows placement of a suture introduced through the lumen of the other needle. Once repeated, the stomach can be pexied at two points, approximately 2 cm apart. We compared Lap-PEG (n = 23) with F-PEG (n = 6) where the mean ages and weights at surgery and sex ratios were similar. All cases were uneventful without intraoperative complications, although one postoperative wound infection occurred in a Lap-PEG case. There were no differences in the duration of analgesia, time taken to commence tube feeding, and return to full feeding. However, mean operating time was significantly shorter in F-PEG (28.1 min) versus Lap-PEG (46.1 min) p < 0.05. As per results F-PEG would appear to be as safe as Lap-PEG, but much quicker.

  7. Older individuals' experiences during the assistive technology device service delivery process.

    Science.gov (United States)

    Gramstad, Astrid; Storli, Sissel Lisa; Hamran, Torunn

    2014-07-01

    Providing assistive technology devices to older individuals living in their ordinary homes is an important intervention to increase and sustain independence and to enable ageing at home. However, little is known about older individuals' experiences and needs in the assistive technology device (ATD) service delivery process. The purpose of this study was to investigate older individuals' experiences during the service delivery process of ATDs. Nine older individuals were interviewed three times each throughout the ATD service delivery process. The interviews were analysed within a hermeneutical phenomenological perspective. The results show that the service delivery process could be interpreted as an enigmatic journey and described using four themes: "hope and optimistic expectations", "managing after delivery or needing additional help", "having available help versus being abandoned", and "taking charge or putting up". The results emphasize the need for occupational therapists to maintain an individualized approach towards older clients throughout the service delivery process. The experiences of older individuals were diverse and related to expectations that were not necessarily articulated to the occupational therapist. The situation when the ATD is delivered to the client was highlighted by the clients as an important event with the potential to facilitate a successful service delivery process.

  8. Watt-Level Continuous-Wave Emission from a Bi-Functional Quantum Cascade Laser/Detector

    Science.gov (United States)

    2017-04-18

    cally authorized by the U.S. Government may violate any copyrights that exist in this work. Watt-level continuous- wave emission from a bi- functional ... wave bi- functional devices, opens the perspective of on-chip dual comb spectroscopy. Also for discrete sens- ing setups, one can switch to lasers...seas.harvard.edu Abstract Bi- functional active regions, capable of light generation and detection at the same wavelength, allow a straightforward realization of

  9. Modeling the Link between Left Ventricular Flow and Thromboembolic Risk Using Lagrangian Coherent Structures

    Directory of Open Access Journals (Sweden)

    Karen May-Newman

    2016-11-01

    Full Text Available A thrombus is a blood clot that forms on a surface, and can grow and detach, presenting a high risk for stroke and pulmonary embolism. This risk increases with blood-contacting medical devices, due to the immunological response to foreign surfaces and altered flow patterns that activate the blood and promote thromboembolism (TE. Abnormal blood transport, including vortex behavior and regional stasis, can be assessed from Lagrangian Coherent Structures (LCS. LCS are flow structures that bound transport within a flow field and divide the flow into regions with maximally attracting/repelling surfaces that maximize local shear. LCS can be identified from finite time Lyapunov exponent (FTLE fields, which are computed from velocity field data. In this study, the goal was to use FTLE analysis to evaluate LCS in the left ventricle (LV using velocity data obtained from flow visualization of a mock circulatory loop. A model of dilated cardiomyopathy (DCM was used to investigate the effect of left ventricular assist device (LVAD support on diastolic filling and transport in the LV. A small thrombus in the left ventricular outflow tract was also considered using data from a corresponding LV model. The DCM LV exhibited a direct flow of 0.8 L/cardiac cycle, which was tripled during LVAD support Delayed ejection flow was doubled, further illustrating the impact of LVAD support on blood transport. An examination of the attracting LCS ridges during diastolic filling showed that the increase is due primarily to augmentation of A wave inflow, which is associated with increased vortex circulation, kinetic energy and Forward FTLE. The introduction of a small thrombus in the left ventricular outflow tract (LVOT of the LV had a minimal effect on diastolic inflow, but obstructed systolic outflow leading to decreased transport compared with the unobstructed LVOT geometry. Localized FTLE in the LVOT increased dramatically with the small thrombus model, which reflects

  10. Post-operative ventricular flow dynamics following atrioventricular valve surgical and device therapies: A review.

    Science.gov (United States)

    Nguyen, Yen Ngoc; Ismail, Munirah; Kabinejadian, Foad; Tay, Edgar Lik Wui; Leo, Hwa Liang

    2018-04-01

    Intra-ventricular flow dynamics has recently emerged as an important evaluation and diagnosis tool in different cardiovascular conditions. The formation of vortex pattern during the cardiac cycle has been suggested to play important epigenetic and energy-modulation roles in cardiac remodelling, adaptations and mal-adaptations. In this new perspective, flow alterations due to different cardiovascular procedures can affect the long-term outcome of those procedures. Especially, repairs and replacements performed on atrioventricular valves are likely to exert direct impact on intra-ventricular flow pattern. In this review, current consensus around the roles of vortex dynamics in cardiac function is discussed. An overview of physiological vortex patterns found in healthy left and right ventricles as well as post-operative ventricular flow phenomenon owing to different atrioventricular valvular procedures are reviewed, followed by the summary of different vortex identification schemes used to characterise intraventricular flow. This paper also emphasises on future research directions towards a comprehensive understanding of intra-cardiac flow and its clinical relevance. The knowledge could encourage more effective pre-operative planning and better outcomes for current clinical practices. Copyright © 2018. Published by Elsevier Ltd.

  11. Percutaneous closure of postoperative ventricular septal residual left-to-right shunt with the China made device

    International Nuclear Information System (INIS)

    Qin Yongwen; Zhao Xianxian; Wu Hong; Ding Jijun; Cao Jiang; Zheng Xin

    2007-01-01

    Objective: To evaluate the feasibility and efficacy of percutaneous transcatheter closure of residual ventricular septal defect (VSD)after surgical closure using China made-nitinol VSD device. Methods: Transcatheter closure was attempted in 11 patients (5 males, 6 females)with a residual VSD following surgical closure. The mean residual VSD narrowest diameter was(5.82 ± 2.09) mm (range from 3 to 9 mm)by echocardiography. A 6 F-9 F delivery sheath was advanced across the residual VSD over a guidewire from femoral vein to deploy the occluder under guidance of left ventriculography and transthoracic echocardiography. Results: The left ventriculography showed membranous part aneurism-like residual VSD in 8 patients and funnel type in 3 cases. There were multiple outlet in 5 cases and one outlets in 6 cases, with mean residual VSD narrowest diameter of (6.09 ± 1.58) mm (range from 3 to 9 mm)measured by left ventriculography. The diameter of occluder was (9.18 ± 2.79) mm (range from 8 to 12 mm). Complete closure of the defect was obtained in 10 cases, and another small residual shunt still remained in one case who had four outlets been treated by 2 occluders. No aortic valvular regurgitation occured in all patients except 1 patient presented complete atrioventricular block within 3 days after the procedure and recovered 2 weeks later with intravenous steroids therapy; and no other complications occured. The fluoroscopy time was(16.91 ± 4.23) min (range from 8 to 30 min). During follow-up from 1 m - 4 y, only 1 case showed residual shunt, and the other had no episodes of endocarditis, thromboembolism, hemolysis, infectious endocarditis, displacement of the occluder and aortic valvular regurgitation. Conclusion: Transcatheter closure of postoperative ventricular septal residual left-to-right shunt with China made-nitinol occluder is safe and effective. (authors)

  12. First Turkish Experience with the MicroMed DeBakey VAD®

    OpenAIRE

    Kucukaksu, Deniz Suha; Sener, Erol; Undar, Akif; Noon, George P.; Tasdemir, Oguz

    2003-01-01

    Mechanical bridging to cardiac transplantation with a ventricular assist device may be a life-saving procedure for patients with end-stage heart failure. Here we report our 3 cases of patients implanted with the MicroMed DeBakey VA® (ventricular assist device). Three male patients, aged 37, 41, and 40, had end-stage left heart failure due to idiopathic cardiomyopathy and were listed for cardiac transplantation. They had progressive hemodynamic deterioration. Although Patient 1 underwent surge...

  13. Layer Structured Bismuth Selenides of Bi2Se3 and Bi3Se4 for High Energy and Flexible All-Solid-State Micro-Supercapacitors.

    Science.gov (United States)

    Hao, Chunxue; Wang, Lidan; Wen, Fusheng; Xiang, Jianyong; Li, Lei; Hu, Wentao; Liu, Zhongyuan

    2017-12-20

    Bismuth selenides (Bi2Se3 and Bi3Se4), both of which have the layered rhombohedral crystal structure, and found to be useful as electrode materials for supercapacitor application in this work. Bi2Se3 nanoplates as electrode material exhibit much better performance than that of Bi3Se4 nanoparticles in liquid electrolyte system (6 M KOH), which delivers a higher specific capacitance (272.9 F/g) than that of Bi3Se4 (193.6 F/g) at 5 mV/s. This result would may be attributed to that Bi2Se3 nanoplates possess more active electrochemical surfaces for the reversible surface redox reactions owing to its planar quintuple stacked layers (septuple layers for Bi3Se4). For the demand of electronic skin, we used a novel flexible annular interdigital structure electrode applying for all-solid-state micro-supercapacitors (AMSCs). Bi2Se3 AMSCs device delivers a much more excellent supercapacitor performance, exhibits a large stack capacitance 89.5 F/cm3 (Bi3Se4: 79.1 F/cm3) at 20 mV/s, a high energy density 17.9 mWh/cm3 and high power density 18.9 W/cm3. The bismuth selenides also exhibit good cycle stability, retention 95.5% (90.3%) after 1000 c for Bi2Se3 (Bi3Se4). Obviously, Bi2Se3 nanoplates can be promising electrode materials for flexible annular interdigital all-solid-sate supercapacitor. © 2017 IOP Publishing Ltd.

  14. Physical interface dynamics alter how robotic exosuits augment human movement: implications for optimizing wearable assistive devices.

    Science.gov (United States)

    Yandell, Matthew B; Quinlivan, Brendan T; Popov, Dmitry; Walsh, Conor; Zelik, Karl E

    2017-05-18

    Wearable assistive devices have demonstrated the potential to improve mobility outcomes for individuals with disabilities, and to augment healthy human performance; however, these benefits depend on how effectively power is transmitted from the device to the human user. Quantifying and understanding this power transmission is challenging due to complex human-device interface dynamics that occur as biological tissues and physical interface materials deform and displace under load, absorbing and returning power. Here we introduce a new methodology for quickly estimating interface power dynamics during movement tasks using common motion capture and force measurements, and then apply this method to quantify how a soft robotic ankle exosuit interacts with and transfers power to the human body during walking. We partition exosuit end-effector power (i.e., power output from the device) into power that augments ankle plantarflexion (termed augmentation power) vs. power that goes into deformation and motion of interface materials and underlying soft tissues (termed interface power). We provide empirical evidence of how human-exosuit interfaces absorb and return energy, reshaping exosuit-to-human power flow and resulting in three key consequences: (i) During exosuit loading (as applied forces increased), about 55% of exosuit end-effector power was absorbed into the interfaces. (ii) However, during subsequent exosuit unloading (as applied forces decreased) most of the absorbed interface power was returned viscoelastically. Consequently, the majority (about 75%) of exosuit end-effector work over each stride contributed to augmenting ankle plantarflexion. (iii) Ankle augmentation power (and work) was delayed relative to exosuit end-effector power, due to these interface energy absorption and return dynamics. Our findings elucidate the complexities of human-exosuit interface dynamics during transmission of power from assistive devices to the human body, and provide insight into

  15. Annealing Effect on the Photoelectrochemical Properties of BiVO_4 Thin Film Electrodes

    International Nuclear Information System (INIS)

    Siti Nur Farhana Mohd Nasir; Mohd Asri Mat Teridi; Mehdi Ebadi; Sagu, J.S.

    2015-01-01

    Monoclinic bismuth vanadate (BiVO_4) thin film electrodes were fabricated on fluorine-doped tin oxide via aerosol-assisted chemical vapour deposition (AACVD). Annealing and without annealing effect of thin films were analysed by X-ray diffraction (XRD), field emission scanning electron microscopy (FESEM), ultraviolet-visible spectrophotometry (UV-Vis) and current voltage measurement. All BiVO_4 thin films showed an anodic photocurrent. The sample of BiVO_4 annealed at 400 degree Celsius exhibited the highest photocurrent density of 0.44 mAcm"-"2 vs. Ag/ AgCl at 1.23 V. (author)

  16. Utilization of assistive devices for students with disabilities in the public schools

    Directory of Open Access Journals (Sweden)

    Carolina Bastos Plotegher

    2013-04-01

    Full Text Available Introduction: Assistive technology is an area of expanding knowledge in Brazil. Its use in school can help students with disabilities in performing important tasks to participate in different activities. Objectives: to report the experience of using assistive devices in the academic achievement of students with disabilities included in the regular school system of the municipality of Sao Carlos, state of Sao Paulo. Method: it was developed from an extension project conducted in 2010. Thirteen students with various types of disabilities participated in the project. The interventions were based on the School Function Assessment with the teachers to know the students’ difficulties. The students were also observed performing school tasks. Results: Forty-seven adaptations were made: thickeners, rings for zippers, slants, communication boards, non-slip mats, among others. Besides the adjustments, orientation regarding use of the devices was provided for teachers and persons responsible for the students. Conclusion: we believe that the project benefited the students, because it produced higher academic achievement and provided better school conditions for their school inclusion. For the undergraduate students of Occupational Therapy, the project enabled the dealing with real issues of inclusion and school interventions, thus approaching theory to practice.

  17. Electrochemically deposited BiTe-based nano wires for thermoelectric applications

    International Nuclear Information System (INIS)

    Inn-Khuan, N.; Kuan-Ying, K.; Che Zuraini Che Abdul Rahman; Nur Ubaidah Saidin; Suhaila Hani Ilias; Thye-Foo, C.

    2013-01-01

    Full-text: Nano structured materials systems such as thin-films and nano wires (NWs) are promising for thermoelectric power generation and refrigeration compared to traditional counterparts in bulk, due to their enhanced thermoelectric figures-of-merit. BiTe and its derivative compounds, in particular, are well-known for their near-room temperature thermoelectric performance. In this work, both the binary and ternary BiTe-based nano wires namely, BiTe and BiSbTe, were synthesized using template-assisted electrodeposition. Diameters of the nano wires were controlled by the pore sizes of the anodised alumina (AAO) templates used. Systematic study on the compositional change as a function of applied potential was carried out via Linear Sweep Voltametry (LSV). Chemical compositions of the nano wires were studied using Energy Dispersive X-ray Spectrometry (EDXS) and their microstructures evaluated using diffraction and imaging techniques. Results from chemical analysis on the nano wires indicated that while the Sb content in BiSbTe nano wires increased with more negative deposition potentials, the formation of Te 0 and Bi 2 Te 3 were favorable at more positive potentials. (author)

  18. Effect of Smaller Left Ventricular Capture Threshold Safety Margins to Improve Device Longevity in Recipients of Cardiac Resynchronization-Defibrillation Therapy.

    Science.gov (United States)

    Steinhaus, Daniel A; Waks, Jonathan W; Collins, Robert; Kleckner, Karen; Kramer, Daniel B; Zimetbaum, Peter J

    2015-07-01

    Device longevity in cardiac resynchronization therapy (CRT) is affected by the pacing capture threshold (PCT) and programmed pacing amplitude of the left ventricular (LV) pacing lead. The aims of this study were to evaluate the stability of LV pacing thresholds in a nationwide sample of CRT defibrillator recipients and to determine potential longevity improvements associated with a decrease in the LV safety margin while maintaining effective delivery of CRT. CRT defibrillator patients in the Medtronic CareLink database were eligible for inclusion. LV PCT stability was evaluated using ≥2 measurements over a 14-day period. Separately, a random sample of 7,250 patients with programmed right atrial and right ventricular amplitudes ≤2.5 V, LV thresholds ≤ 2.5 V, and LV pacing ≥90% were evaluated to estimate theoretical battery longevity improvement using LV safety margins of 0.5 and 1.5 V. Threshold stability analysis in 43,256 patients demonstrated LV PCT stability of 1 V had the greatest increases in battery life (mean increase 0.86 years, 95% confidence interval 0.85 to 0.87). In conclusion, nearly all CRT defibrillator patients had LV PCT stability <1.0 V. Decreasing the LV safety margin from 1.5 to 0.5 V provided consistent delivery of CRT for most patients and significantly improved battery longevity. Copyright © 2015 Elsevier Inc. All rights reserved.

  19. Left ventricular remodeling and change of systolic function after closure of patent ductus arteriosus in adults: device and surgical closure.

    Science.gov (United States)

    Jeong, Young-Hoon; Yun, Tae-Jin; Song, Jong-Min; Park, Jung-Jun; Seo, Dong-Man; Koh, Jae-Kon; Lee, Se-Whan; Kim, Mi-Jeong; Kang, Duk-Hyun; Song, Jae-Kwan

    2007-09-01

    Left ventricular (LV) remodeling and predictors of LV systolic function late after closure of patent ductus arteriosus (PDA) in adults remain to be clearly demonstrated. In 45 patients with PDA, including 28 patients who received successful occlusion using the Amplatzer device (AD group) (AGA, Golden Valley, MN) and 17 patients who received surgical closure (OP group), echocardiography studies were performed before closure and 1 day (AD group) or within 7 days (OP group) after closure, and then were repeated at > or = 6 months (17 +/- 13 months). In both groups, LV ejection fraction (EF) and end-diastolic volume index were significantly decreased immediately after closure, whereas end-systolic volume index did not change. During the long-term follow-up period, end-systolic as well as end-diastolic volume indices decreased significantly in both groups and LV EF recovered compared to the immediate postclosure state. However, LV EF remained low compared to the preclosure state. Five patients (11.1%) including 3 patients in the AD group and 2 patients in the OP group showed persistent late LV systolic dysfunction (EF or = 62% had a sensitivity of 72% and a specificity of 83% for predicting late normal LV EF after closure. Left ventricular EF remains low late after PDA closure compared with preclosure state in adults. Preclosure LV EF is the best index to predict late postclosure LV EF.

  20. Processing of bulk Bi-2223 high-temperature superconductor

    Directory of Open Access Journals (Sweden)

    Alexander Polasek

    2005-12-01

    Full Text Available The Bi2Sr2Ca2Cu3 O10+x (Bi-2223 is one of the main high temperature superconductors for applications. One of these applications is the Superconductor Fault Current Limiter (SCFCL, which is a very promising high temperature superconducting device. SCFCL's can be improved by using bulk superconductors with high critical currents, which requires a sufficiently dense and textured material. In the present work, a process for improving the microstructure of Bi-2223 bulk samples is investigated. Pressed precursor blocks are processed by sintering with a further partial melting step, in order to enhance the Bi-2223 grain texture and to healing cracks induced by pressing. In order to improve the microstructure, the precursor is mixed with silver powder before pressing. Samples with and without silver powder have been studied, with the aim of investigating the influence of silver on the microstructure evolution. The phase contents and the microstructure obtained have been analyzed through XRD and SEM/EDS. The electromagnetic characterization has been performed by Magnetic Susceptibility Analysis. We present and discuss the process and the properties of the superconducting blocks. High fractions of textured Bi-2223 grains have been obtained.

  1. Surface Modifications of Polymeric Materials for Application in Artificial Heart and Circulatory Assist Devices

    NARCIS (Netherlands)

    Feijen, J.; Engbers, G.H.M.; Terlingen, J.G.A.; van Delden, C.J.; Poot, A.A.; Vaudaux, P.; Akutsu, Tetsuzo; Koyanagi, Hitoshi

    1996-01-01

    Several methods have been developed to modify the surfaces of materials used in artificial hearts and circulatory assist devices to suppress the host response, especially with respect to the occurrence of clotting, cellular damage, and infections. In this review, special attention is paid to

  2. Modification of photosensing property of CdS–Bi{sub 2}S{sub 3} bi-layer by thermal annealing and swift heavy ion irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Shaikh, Shaheed U.; Siddiqui, Farha Y. [Thin Film and Nanotechnology Laboratory, Department of Physics (India); Department of Nanotechnology, Dr. Babasaheb Ambedkar Marathwada University, Aurangabad 431004 (India); Singh, Fouran; Kulriya, Pawan K. [Inter University Accelerator Center, Aruna Asaf Ali Marg, New Delhi 110 067 (India); Phase, D.M. [UGC DAE Consortium for Scientific Research, Khandwa Road, Indore 452017 (India); Sharma, Ramphal, E-mail: ramphalsharma@yahoo.com [Thin Film and Nanotechnology Laboratory, Department of Physics (India); Department of Nanotechnology, Dr. Babasaheb Ambedkar Marathwada University, Aurangabad 431004 (India)

    2016-02-01

    The CdS–Bi{sub 2}S{sub 3} bi-layer thin films have been deposited on Indium Tin Oxide (ITO) glass substrates at room temperature by Chemical Bath Deposition Technique (CBD) and bi-layer thin films were annealed in air atmosphere for 1 h at 250 {sup °}C. The air annealed sample was irradiated using Au{sup 9+} ions at the fluence 5 × 10{sup 11} ion/cm{sup 2} with 120 MeV energy. Effects of Swift Heavy Ion (SHI) irradiation on CdS–Bi{sub 2}S{sub 3} bi-layer thin films were studied. The results are explained on the basis annealing and high electronic excitation, using X-ray diffraction (XRD), Selective Electron Area Diffraction (SEAD), Atomic Force Microscopy (AFM), Raman Spectroscopy, UV spectroscopy and I–V characteristics. The photosensing property after illumination of visible light over the samples is studied. These as-deposited, annealed and irradiated bi-layer thin films are used to sense visible light at room temperature. - Graphical abstract: Schematic illustration of CdS–Bi{sub 2}S{sub 3} bi-layer thin film (a) As-deposited (b) Annealed (c) irradiated sample respectively (d) Model of bi-layer photosensor device (e) Graph of illumination intensity verses photosensitivity. - Highlights: • CdS–Bi{sub 2}S{sub 3} bi-layer thin film prepared at room temperature. • Irradiated using Au{sup 9+} ions at the fluence of 5 × 10{sup 11} ion/cm{sup 2} with 120 MeV energy. • Study of modification induced by irradiations. • Study of Photosensitivity after annealing and irradiation.

  3. Systolic left ventricular function according to left ventricular concentricity and dilatation in hypertensive patients

    DEFF Research Database (Denmark)

    Bang, Casper; Gerdts, Eva; Aurigemma, Gerard P

    2013-01-01

    Left ventricular hypertrophy [LVH, high left ventricular mass (LVM)] is traditionally classified as concentric or eccentric based on left ventricular relative wall thickness. We evaluated left ventricular systolic function in a new four-group LVH classification based on left ventricular dilatation...... [high left ventricular end-diastolic volume (EDV) index and concentricity (LVM/EDV)] in hypertensive patients....

  4. Left ventricular function in patients with ventricular arrhythmias and aortic valve disease

    International Nuclear Information System (INIS)

    Santinga, J.T.; Kirsh, M.M.; Brady, T.J.; Thrall, J.; Pitt, B.

    1983-01-01

    Forty patients having aortic valve replacement were evaluated preoperatively for ventricular arrhythmia and left ventricular ejection fraction. Arrhythmias were classified as complex or simple using the Lown criteria on the 24-hour ambulatory electrocardiogram; ejection fractions were determined by radionuclide gated blood pool analysis and contrast angiography. The ejection fractions determined by radionuclide angiography were 59.1 +/- 13.1% for 26 patients with simple or no ventricular arrhythmias, and 43.9 +/- 20.3% for 14 patients with complex ventricular arrhythmias (p less than 0.01). Ejection fractions determined by angiography, available for 31 patients, were also lower in patients with complex ventricular arrhythmias (61.1 +/- 16.3% versus 51.4 +/- 13.4%; p less than 0.05). Seven of 9 patients showing conduction abnormalities on the electrocardiogram had complex ventricular arrhythmias. Eight of 20 patients with aortic stenosis had complex ventricular arrhythmias, while 2 of 13 patients with aortic insufficiency had such arrhythmias. It is concluded that decreased left ventricular ejection fraction, intraventricular conduction abnormalities, and aortic stenosis are associated with an increased frequency of complex ventricular arrhythmias in patients with aortic valve disease

  5. Rest and exercise ventricular function in adults with congenital ventricular septal defects

    International Nuclear Information System (INIS)

    Jablonsky, G.; Hilton, J.D.; Liu, P.P.; Morch, J.E.; Druck, M.N.; Bar-Shlomo, B.Z.; McLaughlin, P.R.

    1983-01-01

    Rest and exercise right and left ventricular function were compared using equilibrium gated radionuclide angiography in 19 normal sedentary control subjects and 34 patients with hemodynamically documented congenital ventricular septal defect (VSD). Gated radionuclide angiography was performed at rest and during each level of graded supine bicycle exercise to fatigue. Heart rate, blood pressure, maximal work load achieved, and right and left ventricular ejection fractions were assessed. The control subjects demonstrated an increase in both the left and right ventricular ejection fractions with exercise. All study groups failed to demonstrate an increase in ejection fraction in either ventricle with exercise. Furthermore, resting left ventricular ejection fraction in Groups 2 and 3 was lower than that in the control subjects and resting right ventricular ejection fraction was lower in Group 3 versus control subjects. Thus left and right ventricular function on exercise were abnormal in patients with residual VSD as compared with control subjects; rest and exercise left ventricular ejection fractions remained abnormal despite surgical closure of VSD in the remote past; resting left and right ventricular function was abnormal in patients with Eisenmenger's complex; lifelong volume overload may be detrimental to myocardial function

  6. Prognostic significance of nonsustained ventricular tachycardia after revascularization.

    Science.gov (United States)

    Mittal, Suneet; Lomnitz, David J; Mirchandani, Sunil; Stein, Kenneth M; Markowitz, Steven M; Slotwiner, David J; Iwai, Sei; Das, Mithilesh K; Lerman, Bruce B

    2002-04-01

    Two randomized trials (Multicenter Automatic Defibrillator Implantation Trial [MADIT] and Multicenter Unsustained Tachycardia Trial [MUSTT]) suggest that implantable cardioverter defibrillator (ICD) placement is associated with improved survival in patients with coronary artery disease, depressed left ventricular function, and nonsustained ventricular tachycardia (VT) who also have inducible sustained VT. However, neither study directly addresses the management of such patients who develop nonsustained VT early after revascularization. We evaluated 109 consecutive patients who underwent electrophysiologic testing to evaluate nonsustained VT, which occurred 5 +/- 4 days following revascularization. Sustained monomorphic VT was inducible in 46 (42%) patients; these patients received an ICD. The remaining 63 (58%) noninducible patients received neither antiarrhythmic drug therapy nor an ICD. During 27 +/- 12 months of follow-up, 15 (33%) of 45 patients with an implanted ICD received at least one appropriate therapy from the device and 26 (24%) of the 109 study patients died. The 1- and 2-year freedom from ventricular tachycardia/fibrillation or sudden death in noninducible patients (97% and 93%) was significantly greater than that of inducible patients (84% and 71%; P = 0.001). However, no difference was observed in total mortality. Patients with nonsustained VT during the early postrevascularization period who have inducible VT have a high incidence of arrhythmic events. Although this study was not designed to assess the impact of ICD placement on the total mortality of inducible patients, the finding that one third of these patients received appropriate ICD therapy suggests that the device may have a protective effect in these patients.

  7. Interacting with and via mobile devices and mobile robots in an assisted living setting

    Directory of Open Access Journals (Sweden)

    Maria Dagioglou

    2015-05-01

    Full Text Available Using robotic home assistants as a platform for remote health monitoring offers several advantages, but also presents considerable challenges related to both the technical immaturity of home robotics and to user acceptance issues. In this paper we explore tablets and similar mobile devices as the medium of communication between robots and their users, presenting relevant current and planned research in humanrobot interaction that can help the telehealth community circumvent technical shortcomings, improve user acceptance, and maximize the quality of the data collected by robotic home assistants.

  8. Network-Assisted Distributed Fairness-Aware Interference Coordination for Device-to-Device Communication Underlaid Cellular Networks

    Directory of Open Access Journals (Sweden)

    Francis Boabang

    2017-01-01

    Full Text Available Device-to-device (D2D communication underlaid cellular network is considered a key integration feature in future cellular network. However, without properly designed interference management, the interference from D2D transmission tends to degrade the performance of cellular users and D2D pairs. In this work, we proposed a network-assisted distributed interference mitigation scheme to address this issue. Specifically, the base station (BS acts as a control agent that coordinates the cross-tier interference from D2D transmission through a taxation scheme. The cotier interference is controlled by noncooperative game amongst D2D pairs. In general, the outcome of noncooperative game is inefficient due to the selfishness of each player. In our game formulation, reference user who is the victim of cotier interference is factored into the payoff function of each player to obtain fair and efficient outcome. The existence, uniqueness of the Nash Equilibrium (NE, and the convergence of the proposed algorithm are characterized using Variational Inequality theory. Finally, we provide simulation results to evaluate the efficiency of the proposed algorithm.

  9. Towards Next Generation BI Systems

    DEFF Research Database (Denmark)

    Varga, Jovan; Romero, Oscar; Pedersen, Torben Bach

    2014-01-01

    Next generation Business Intelligence (BI) systems require integration of heterogeneous data sources and a strong user-centric orientation. Both needs entail machine-processable metadata to enable automation and allow end users to gain access to relevant data for their decision making processes....... This framework is based on the findings of a survey of current user-centric approaches mainly focusing on query recommendation assistance. Finally, we discuss the benefits of the framework and present the plans for future work....

  10. LVAD pannus complicating destination therapy

    Directory of Open Access Journals (Sweden)

    Maya Ignaszewski

    2017-11-01

    Full Text Available Despite advances in technology, ventricular assist devices still experience a number of complications limiting their long-term use. We present a 73-year-old woman implanted with a left ventricular assist device (LVAD five years prior due to end-stage dilated cardiomyopathy, who died several weeks after admission to the hospital. Post-mortem examination revealed a large obstructing pannus in the LVAD inflow. As a result of increased LVAD use, complications such as infection, device thrombosis and pannus must be promptly recognized and managed appropriately to ensure the greatest chance of patient survival.

  11. A novel vibration assisted polishing device based on the flexural mechanism driven by the piezoelectric actuators

    Directory of Open Access Journals (Sweden)

    Guilian Wang

    2018-01-01

    Full Text Available The vibration assisted polishing has widely application fields because of higher machining frequency and better polishing quality, especially the polishing with the non-resonant mode that is regarded as a kind of promising polishing method. This paper reports a novel vibration assisted polishing device, consisting of the flexible hinge mechanism driven by the piezoelectric actuators, which is suitable for polishing planes or curve surfaces with slow curvature. Firstly, the generation methods of vibration trajectory are investigated for the same frequency and different frequency signals’ inputs, respectively, and then the types of elliptic and Lissajous’s vibration trajectories are generated respectively. Secondly, a flexural mechanism consisting of the right circular flexible hinges and the leaf springs is developed to produce two-dimensional vibration trajectory. Statics and dynamics investigating of this flexible mechanism are finished in detail. The analytical models about input and output compliances of the flexural mechanism are established according to the matrix-based compliance modeling, and the dynamic model of the flexural mechanism based on the Euler-Lagrange equation is also presented. The finite element model of the flexural mechanism was established to carry out the numerical simulation in order to testify the rationality of device design. Finally, the polishing experiment is carried out to prove the effectiveness of the vibration device. The experimental results show that this novel vibration assisted polishing device developed in this study can remove more effectively the cutting marks left by last process and obviously reduce the workpiece surface roughness.

  12. Arrhythmogenic Right Ventricular Cardiomyopathy in an Endurance Athlete Presenting with Ventricular Tachycardia and Normal Right Ventricular Function.

    Science.gov (United States)

    Hedley, Jeffrey S; Al Mheid, Ibhar; Alikhani, Zoubin; Pernetz, Maria A; Kim, Jonathan H

    2017-08-01

    Arrhythmogenic right ventricular cardiomyopathy, a genetically inherited disease that results in fibrofatty replacement of normal cardiac myocytes, has been associated with sudden cardiac death in athletes. Long-term participation in endurance exercise hastens the development of both the arrhythmic and structural arrhythmogenic right ventricular cardiomyopathy phenotypes. We describe the unusual case of a 34-year-old, symptomatic, female endurance athlete who had arrhythmogenic right ventricular cardiomyopathy in the presence of a structurally normal right ventricle. Clinicians should be aware of this infrequent presentation when evaluating athletic patients who have ventricular arrhythmias and normal findings on cardiac imaging studies.

  13. Prophylactic implantable defibrillator in patients with arrhythmogenic right ventricular cardiomyopathy/dysplasia and no prior ventricular fibrillation or sustained ventricular tachycardia.

    LENUS (Irish Health Repository)

    Corrado, Domenico

    2010-09-21

    The role of implantable cardioverter-defibrillator (ICD) in patients with arrhythmogenic right ventricular cardiomyopathy\\/dysplasia and no prior ventricular fibrillation (VF) or sustained ventricular tachycardia is an unsolved issue.

  14. Improvement of reliability and speed of phase change memory devices with N7.9(Ge46.9Bi7.2Te45.9) films

    Science.gov (United States)

    Park, J. H.; Kim, S.-W.; Kim, J. H.; Ko, D.-H.; Wu, Z.; Cho, S. L.; Ahn, D.; Ahn, D. H.; Lee, J. M.; Nam, S. W.

    2015-08-01

    In this study, we propose a nitrogen-incorporated GeBiTe ternary phase of N7.9(Ge46.9Bi7.2Te45.9) as a phase change material for reliable PCM (Phase Change Memory) with high speed operation. We found that the N7.9(Ge46.9Bi7.2Te45.9) film shows the resistance value of 40 kΩ after annealing at 440oC for 10 minutes, which is much higher than the value of 3.4 kΩ in the case of conventional N7.0(Ge22.0Sb22.0Te56.0) films. A set operation time of 14 nsec was achieved in the devices due to the increased probability of the nucleation by the addition of the elemental Bi. The long data retention time of 10 years at 85oC on the base of 1% failure was obtained as the result of higher activation energy of 2.52 eV for the crystallization compared to the case of N7.0(Ge22.0Sb22.0Te56.0) film, in which the activation energy is 2.1 eV. In addition, a reset current reduction of 27% and longer cycles of endurance as much as 2 order of magnitude compared to the case of N7.0(Ge22.0Sb22.0Te56.0) were observed at a set operation time of 14 nsec. Our results show that N7.9(Ge46.9Bi7.2Te45.9) is highly promising for use as a phase change material in reliable PCMs with high performance and also in forthcoming storage class memory applications, too.

  15. Improvement of reliability and speed of phase change memory devices with N7.9(Ge46.9Bi7.2Te45.9 films

    Directory of Open Access Journals (Sweden)

    J. H. Park

    2015-08-01

    Full Text Available In this study, we propose a nitrogen-incorporated GeBiTe ternary phase of N7.9(Ge46.9Bi7.2Te45.9 as a phase change material for reliable PCM (Phase Change Memory with high speed operation. We found that the N7.9(Ge46.9Bi7.2Te45.9 film shows the resistance value of 40 kΩ after annealing at 440oC for 10 minutes, which is much higher than the value of 3.4 kΩ in the case of conventional N7.0(Ge22.0Sb22.0Te56.0 films. A set operation time of 14 nsec was achieved in the devices due to the increased probability of the nucleation by the addition of the elemental Bi. The long data retention time of 10 years at 85oC on the base of 1% failure was obtained as the result of higher activation energy of 2.52 eV for the crystallization compared to the case of N7.0(Ge22.0Sb22.0Te56.0 film, in which the activation energy is 2.1 eV. In addition, a reset current reduction of 27% and longer cycles of endurance as much as 2 order of magnitude compared to the case of N7.0(Ge22.0Sb22.0Te56.0 were observed at a set operation time of 14 nsec. Our results show that N7.9(Ge46.9Bi7.2Te45.9 is highly promising for use as a phase change material in reliable PCMs with high performance and also in forthcoming storage class memory applications, too.

  16. Development of mechanical circulatory support devices in China.

    Science.gov (United States)

    Wang, Wei; Zhu, De-Ming; Ding, Wen-Xiang

    2009-11-01

    Myocardial dysfunction leading to low cardiac output syndrome is a common clinical pathophysiological state. Currently, the use of mechanical circulatory support (MCS) is an essential aspect of the treatment of patients with cardiac failure. Several groups in China are engaged in the design and development of MCS devices. These devices can be classified as pulsatile, rotary, and total artificial heart (TAH). There are two types of pulsatile pump, which are driven by air (pneumatic). One of these pumps, the Luo-Ye pump, has been used clinically for short-term support since 1998. The other is a push-plate left ventricular device, which has a variable rate mode. Various rotary devices are classified into axial and centrifugal pumps, depending on the impeller geometry. Most rotary pumps are based on the maglev principle, and some types have been used clinically. Others are still being studied in the laboratory or in animal experiments. Furthermore, certain types of total implantable pump, such as the UJS-III axial pump and the UJS-IV aortic valvo-pump, have been developed. Only one type of TAH has been developed in China. The main constituents of this artificial heart are two axial pumps, two reservoir tanks mimicking the right and left atria, flow meters, two pressure gauges, and a resistance adaptor. Although the development of mechanical assist devices in China is still in a nascent stage, a number of different types of MCS devices are currently being studied.

  17. Hollow mandrin facilitates external ventricular drainage placement.

    Science.gov (United States)

    Heese, O; Regelsberger, J; Kehler, U; Westphal, M

    2005-07-01

    Placement of ventricular catheters is a routine procedure in neurosurgery. Ventricle puncture is done using a flexible ventricular catheter stabilised by a solid steel mandrin in order to improve stability during brain penetration. A correct catheter placement is confirmed after removing the solid steel mandrin by observation of cerebrospinal fluid (CSF) flow out of the flexible catheter. Incorrect placement makes further punctures necessary. The newly developed device allows CSF flow observation during the puncture procedure and in addition precise intracranial pressure (ICP) measurement. The developed mandrin is hollow with a blunt tip. On one side 4-5 small holes with a diameter of 0.8 mm are drilled corresponding exactly with the holes in the ventricular catheter, allowing CSF to pass into the hollow mandrin as soon as the ventricle is reached. By connecting a small translucent tube at the distal portion of the hollow mandrin ICP can be measured without loss of CSF. The system has been used in 15 patients with subarachnoid haemorrhage (SAH) or intraventricular haemeorrhage (IVH) and subsequent hydrocephalus. The new system improved the external ventricular drainage implantation procedure. In all 15 patients catheter placement was correct. ICP measurement was easy to perform immediately at ventricle puncture. In 4 patients at puncture no spontaneous CSF flow was observed, therefore by connecting a syringe and gentle aspiration of CSF correct placement was confirmed in this unexpected low pressure hydrocephalus. Otherwise by using the conventional technique further punctures would have been necessary. Advantages of the new technique are less puncture procedures with a lower risk of damage to neural structures and reduced risk of intracranial haemorrhages. Implantation of the ventricular catheter to far into the brain can be monitored and this complication can be overcome. Using the connected pressure monitoring tube an exact measurement of the opening

  18. General surgical complications associated with the use of long-term mechanical circulatory support devices: are we 'under-reporting' problems?

    Science.gov (United States)

    Tchantchaleishvili, Vakhtang; Umakanthan, Ramanan; Karp, Seth; Stulak, John M; Keebler, Mary E; Maltais, Simon

    2013-05-01

    Multiple complications are associated with use of ventricular assist devices (VADs). Cardiac-related complications and infections are most frequently reported. VADs, however, can also lead to a number of general surgical complications equally significant in terms of morbidity and mortality. The authors performed a systematic literature search to review current data that specifically relate general surgical complications to patients who undergo left VAD implantation. The review provides a relatively clear understanding of the spectrum of general surgical complications and shows that they contribute significantly to morbidity and mortality in these patients.

  19. Atrioventricular and ventricular-to-ventricular programming in patients with cardiac resynchronization therapy: results from ALTITUDE.

    Science.gov (United States)

    Steinberg, Benjamin A; Wehrenberg, Scott; Jackson, Kevin P; Hayes, David L; Varma, Niraj; Powell, Brian D; Day, John D; Frazier-Mills, Camille G; Stein, Kenneth M; Jones, Paul W; Piccini, Jonathan P

    2015-12-01

    Cardiac resynchronization therapy (CRT) improves outcomes in patients with heart failure, yet response rates are variable. We sought to determine whether physician-specified CRT programming was associated with improved outcomes. Using data from the ALTITUDE remote follow-up cohort, we examined sensed atrioventricular (AV) and ventricular-to-ventricular (VV) programming and their associated outcomes in patients with de novo CRT from 2009-2010. Outcomes included arrhythmia burden, left ventricular (LV) pacing, and all-cause mortality at 4 years. We identified 5709 patients with de novo CRT devices; at the time of implant, 34% (n = 1959) had entirely nominal settings programmed, 40% (n = 2294) had only AV timing adjusted, 11% (n = 604) had only VV timing adjusted, and 15% (n = 852) had both AV and VV adjusted from nominal programming. Suboptimal LV pacing (5% was lowest in the AV-only adjusted group (17.9%) and highest in the nominal (27.7%) and VV-only adjusted (28.3%) groups. Adjusted all-cause mortality was significantly higher among patients with non-nominal AV delay >120 vs. 180 vs. ≤180 ms, p = 0.4). Nominal settings for de novo CRT implants are frequently altered, most commonly the AV delay. There is wide variability in reprogramming. Patients with nominal or AV-only adjustments appear to have favorable pacing and arrhythmia outcomes. Sensed AV delays less than 120 ms are associated with improved survival.

  20. A case of appropriate inappropriate device therapy: Hyperkalemia-induced ventricular oversensing

    OpenAIRE

    Oudit, Gavin Y; Cameron, Doug; Harris, Louise

    2008-01-01

    The present case describes a patient who received inappropriate, but potentially life-saving, therapy from her implantable cardioverter defibrillator (ICD) in the setting of acute hyperkalemia (plasma potassium concentration = 8 mM). Hyperkalemia was associated with the development of a slow sinusoidal ventricular tachycardia, at a rate of 100 beats/min to 125 beats/min (610 ms to 480 ms) in a patient who is pacemaker-dependent. There was associated fractionation of the ICD electrogram and T ...

  1. Transcatheter closure of post-operative residual ventricular septal defect using a patent ductus arteriosus closure device in an adult: a case report.

    Science.gov (United States)

    Djer, Mulyadi M; Idris, Nikmah S; Alwi, Idrus; Wijaya, Ika P

    2014-07-01

    Transcatheter closure of perimembranous and muscular ventricular septal defect (VSD) has been performed widely and it has more advantages compare to surgery. However, transcatheter closure of residual VSD post operation of complex congenital heart disease is still challenging because of the complexity of anatomy and concern about device stability, so the operator should meticulously choose the most appropriate technique and device. We would like to report a case of transcatheter closure of residual VSD post Rastelli operation in a patient with double outlet right ventricle (DORV), sub-aortic VSD, severe infundibulum pulmonary stenosis (PS) and single coronary artery. The patient had undergone operations for four times, but he still had intractable heart failure that did not response to medications. On the first attempt. we closed the VSD using a VSD occluder, unfortunately the device embolized into the descending aorta, but fortunately we was able to snare it out. Then we decided to close the VSD using a patent ductus arteriosus (PDA occluder). On transesophageal echocardiography (TEE) and angiography evaluation, the device position was stable. Post transcatheter VSD closure, the patient clinical condition improved significantly and he could finally be discharged after a long post-surgery hospitalization. Based on this experience we concluded that the transcatheter closure of residual VSD in complex CHD using PDA occluder could be an effective alternative treatment.

  2. Selenium-assisted controlled growth of graphene–Bi_2Se_3 nanoplates hybrid Dirac materials by chemical vapor deposition

    International Nuclear Information System (INIS)

    Sun, Zhencui; Man, Baoyuan; Yang, Cheng; Liu, Mei; Jiang, Shouzhen; Zhang, Chao; Zhang, Jiaxin; Liu, Fuyan; Xu, Yuanyuan

    2016-01-01

    Graphical abstract: - Highlights: • We synthesize the graphene–Bi_2Se_3 nanoplates hybrid Dirac materials via CVD. • The Se seed layer impels the Bi_2Se_3 plates growing along the lateral direction. • The Se seed layer can supply enough Se atoms to fill the Se vacancies. • The Se seed layer can effectively avoid the interaction of Bi_2Se_3 and the graphene. • The Se seed layer can be used to control the density of the Bi_2Se_3 nanoplates. - Abstract: Se seed layers were used to synthesize the high-quality graphene–Bi_2Se_3 nanoplates hybrid Dirac materials via chemical vapor deposition (CVD) method. The morphology, crystallization and structural properties of the hybrid Dirac materials were characterized by SEM, EDS, Raman, XRD, AFM and HRTEM. The measurement results verify that the Se seed layer on the graphene surface can effectively saturate the surface dangling bonds of the graphene, which not only impel the uniform Bi_2Se_3 nanoplates growing along the horizontal direction but also can supply enough Se atoms to fill the Se vacancies. We also demonstrate the Se seed layer can effectively avoid the interaction of Bi_2Se_3 and the graphene. Further experiments testify the different Se seed layer on the graphene surface can be used to control the density of the Bi_2Se_3 nanoplates.

  3. Prototype of a mechanical assistance device for the wrists' flexion-extension movement

    International Nuclear Information System (INIS)

    Politti, Julio C; Puglisi, Lisandro J; Farfan, Fernando D

    2007-01-01

    Using CMU actuators, a Prototype of Mechanical Assistance Device for the Wrist's Flexion Movement (PMA) was developed and probed in a mechanical model, in order to be implemented in a future as a dynamic powered orthosis or as a rehabilitation assistant instrument. Two Mayor Actuators conformed by three CMU actuators arranged in a series configuration, allows to an artificial hand to be placed in four predefined positions: 0 0 , 20 0 , 40 0 and 60 0 . The synchronism and control of the actuators is achieved with the Programmable Control Module (PCM). It is capable to drive up to six CMU actuators, and possess two different modes of execution: a Manual mode and an Exercise mode. In the Manual Mode, the position of the hand responds directly to the commands of the keyboard of the front panel, and in the Exercise mode, the hand realizes a repetitive and programmed movement. The prototype was tested in 100 positions in the Manual Mode and for 225 works cycles in the Exercise Mode. The relative repetition error was less than 5% for both test. This prototype only consumes 4,15W, which makes it possible to be powered by small rechargeable batteries, allowing its use as a portable device

  4. Does reduced movement restrictions and use of assistive devices affect rehabilitation outcome after total hip replacement?

    DEFF Research Database (Denmark)

    Mikkelsen, Lone Ramer; Petersen, Annemette Krintel; Søballe, Kjeld

    2014-01-01

    slower recovery in patient-reported function after reduction in movement restrictions and use of assistive devices, but the difference was eliminated after 6 weeks. Reduced movement restrictions did not affect the other patient-reported outcomes and led to earlier return to work. CLINICAL REHABILITATION......). This group was compared to patients included the following 3 months with less restricted hip movement and use of assistive devices according to individual needs (unrestricted group). Questionnaires on function, pain, quality of life (HOOS), anxiety (HADS), working status and patient satisfaction were.......004). Return to work 6 weeks after THR for the unrestricted group compared to restricted group was: 53% versus 32% (P=0.045). No significant differences between groups in pain, symptoms, quality of life, anxiety/depression, hip dislocations and patient satisfaction. CONCLUSION: This study showed slightly...

  5. Surface coating for blood-contacting devices

    Science.gov (United States)

    Nair, Ajit Kumar Balakrishnan

    The major problems always encountered with the blood-contacting surfaces are their compatibility, contact blood damage, and thrombogenicity. Titanium nitride (TiN) is a hard, inert, ceramic material that is widely used in the engineering industry. TiN has been proven to be a good biomaterial in its crystalline form, in orthopedic, and in tissue implant applications. This dissertation describes a method to coat amorphous TiN on the blood-contacting surfaces of certain medical devices using the room-temperature sputtering process and to characterize, to test, and to evaluate the coating for a reliable, durable, and compatible blood-contacting surface The blood-compatibility aspects were evaluated with standard, established protocols and procedures to prove the feasibility. An amorphous TiN coating is developed, characterized, tested, and blood compatibility evaluated by applying to the blood-contacting surfaces of stainless steel, catheters, and blood filters. The flexibility characteristics were proven by applying it to the diaphragms of the pulsatile pneumatic ventricular assist device. The results show that amorphous titanium nitride is flexible and adherent to polymeric substrates like polyurethane and polyester. Blood compatibility evaluation showed comparable results with catheters and superior behavior with stainless steel and polyester filters. It is concluded that amorphous titanium nitride can be considered to be applied to the surfaces of some of the medical devices in order to improve blood compatibility.

  6. CTAB-Assisted Hydrothermal Synthesis of Bi2Sn2O7 Photocatalyst and Its Highly Efficient Degradation of Organic Dye under Visible-Light Irradiation

    Directory of Open Access Journals (Sweden)

    Weicheng Xu

    2013-01-01

    Full Text Available Pyrochlore-type Bi2Sn2O7 (BSO nanoparticles have been prepared by a hydrothermal method assisted with a cationic surfactant cetyltrimethylammonium bromide (CTAB. These BSO products were characterized by powder X-ray diffraction (XRD, infrared spectroscopy (IR, scanning electron microscopy (SEM, transmission electron microscopy (TEM, Brunauer-Emmett-Teller (BET, and UV-visible diffuse reflectance spectroscopy (DRS. The results indicated that CTAB alters the surface parameters and the morphology and enhances the photoinduced charge separation rate of BSO. The photocatalytic degradation test using rhodamine B as a model pollutant showed that the photocatalytic activity of the BSO assisted with CTAB was two times that of the reference BSO. Close investigation revealed that the size, the band gap, the structure, and the existence of impurity level played an important role in the photocatalytic activities.

  7. Left thoracotomy HeartWare implantation with outflow graft anastomosis to the descending aorta: a simplified bridge for patients with multiple previous sternotomies.

    Science.gov (United States)

    Umakanthan, Ramanan; Haglund, Nicholas A; Stulak, John M; Joyce, Lyle D; Ahmad, Rashid; Keebler, Mary E; Maltais, Simon

    2013-01-01

    Advances in mechanical circulatory support have been critical in bridging patients awaiting heart transplantation. In addition, improvement in device durability has enabled left ventricular assist device therapy to be applied as destination therapy in those not felt to be transplant candidate. Because of the increasing complexity of patients, there continues to be a need for alternative strategies for device implantation to bridge high-risk patients awaiting heart transplantation, wherein the risks of numerous previous sternotomies may be prohibitive. We present a unique technique for placement of the HeartWare ventricular assist device via left anterior thoracotomy to the descending aorta in a patient awaiting heart transplantation with a history of multiple previous sternotomies.

  8. Stress induced right ventricular dysfunction: An indication of reversible right ventricular ischaemia

    International Nuclear Information System (INIS)

    Underwood, S.R.; Walton, S.; Emanuel, R.W.; Swanton, R.H.; Campos Costa, D.; Laming, P.J.; Ell, P.J.

    1987-01-01

    Stress induced changes in left ventricular ejection fraction are widely used in the detection and assessment of coronary artery disease. This study demonstrates that right ventricular dysfunction may also occur, and assesses its significance in terms of coronary artery anatomy. This study involved 14 normal subjects and 26 with coronary artery disease investigated by equilibrium radionuclide ventriculography, at rest and during maximal dynamic exercise. Mean normal resting right ventricular ejection fraction (RVEF) was 0.40 (SD 0.118), and all normal subjects increased RVEF with stress (mean ΔRVEF+0.13 SD 0.099). Mean ΔRVEF in the subjects with coronary artery disease was significantly lower at 0.00 (SD 0.080), but there was overlap between the two groups. The largest falls in RVEF were seen if the right coronary artery was occluded without retrograde filling. In this subgroup with the most severely compromised right ventricular perfusion (nine subjects), RVEF always fell with stress, and mean ΔRVEF was -0.08 (SD 0.050). There was no significant correlation between ΔLVEF and ΔRVEF, implying that the right ventricular dysfunction was due to right ventricular ischaemia, rather than secondary to left ventricular dysfunction. Stress induced right ventricular ischaemia can therefore be detected readily by radionuclide ventriculography. (orig.)

  9. Design of a Code-Maker Translator Assistive Input Device with a Contest Fuzzy Recognition Algorithm for the Severely Disabled

    Directory of Open Access Journals (Sweden)

    Chung-Min Wu

    2015-01-01

    Full Text Available This study developed an assistive system for the severe physical disabilities, named “code-maker translator assistive input device” which utilizes a contest fuzzy recognition algorithm and Morse codes encoding to provide the keyboard and mouse functions for users to access a standard personal computer, smartphone, and tablet PC. This assistive input device has seven features that are small size, easy installing, modular design, simple maintenance, functionality, very flexible input interface selection, and scalability of system functions, when this device combined with the computer applications software or APP programs. The users with severe physical disabilities can use this device to operate the various functions of computer, smartphone, and tablet PCs, such as sending e-mail, Internet browsing, playing games, and controlling home appliances. A patient with a brain artery malformation participated in this study. The analysis result showed that the subject could make himself familiar with operating of the long/short tone of Morse code in one month. In the future, we hope this system can help more people in need.

  10. An assistance device to help people with trunk impairment maintain posture.

    Science.gov (United States)

    Ogura, Tomoka; Itami, Taku; Yano, Ken'ichi; Mori, Ichidai; Kameda, Kazuhiro

    2017-07-01

    People with trunk impairment cannot lean forward because of the dysfunction of the trunk resulting from events such as cervical cord injury (CCI). It is therefore difficult for such people to work at a table because they may easily fall from their wheelchair, and it is also hard for them to return to their original position. This limits the activities of daily living (ADLs) of people with trunk impairment. These problems can be solved to some extent with equipment such as a wheelchair belt or a spinal orthosis that can help the person to maintain his or her posture. However, people cannot move freely with this equipment. Furthermore, if this equipment is used for a long time, there is a risk of physical pain and skin issues. In this study, we developed a device that assists the trunk of people with trunk impairment when they lean forward. This device supports people with trunk impairment so that they may take their meals at the table and prevents them from falling over their wheelchair without hindering their daily performance when they are sitting normally. The effectiveness of our proposed device was verified by experiments involving having a meal, operating a wheelchair, and colliding with a curb. Our device can help people with trunk impairment by improving their ADLs and quality of life (QOL).

  11. Synthesis and magnetic properties of rare-earth free MnBi alloy: A high-energy hard magnetic material

    Science.gov (United States)

    Sharma, Sanjeev Kumar; Prakash, H. R.; Ram, S.; Pradhan, D.

    2018-04-01

    MnBi is a rare-earth free high-energy magnetic material useful for the permanent magnet based devices. In a simple method, a MnBi alloy was prepared by arc melting method using Mn and Bi metals in 60:40 atomic ratio. In terms of the X-ray diffraction, a crystalline MnBi phase is formed with Bi as impurity phase of the as-prepared alloy. FESEM image of chemically etched sample shows small grains throughout the alloy. SEAD pattern and lattice image were studied to understand the internal microstructure of the alloy. The thermomagnetic curves measured in ZFC-FC cycles over 5-380 K temperatures at 500 Oe field, shows the induced magnetization of 5-25 % in the sample. The coercivity values, 7.455 kOe (13.07 emu/g magnetization) at 380 K, and 5.185k Oe (14.75 emu/g magnetization) at 300 K, are observed in the M-H hysteresis loops. A decreased value 0.181kOe (18.05 emu/g magnetization) appears at 100 K due to the change in the magnetocrystalline anisotropy. The results are useful to fabricate small MnBi magnets for different permanent magnets based devices.

  12. Management and outcomes in patients with moderate or severe functional mitral regurgitation and severe left ventricular dysfunction

    DEFF Research Database (Denmark)

    Samad, Zainab; Shaw, Linda K; Phelan, Matthew

    2015-01-01

    AIMS: The management and outcomes of patients with functional moderate/severe mitral regurgitation and severe left ventricular (LV) systolic dysfunction are not well defined. We sought to determine the characteristics, management strategies, and outcomes of patients with moderate or severe mitral...... fraction ≤ 30% or LV end-systolic diameter > 55 mm). We examined treatment effects in two ways. (i) A multivariable Cox proportional hazards model was used to assess the independent relationship of different treatment strategies and long-term event (death, LV assist device, or transplant)-free survival...... [hazard ratio (HR) 0.56, 95% confidence interval (CI) 0.42-0.76] and CABG with MV surgery (HR 0.58, 95% CI 0.44-0.78) were associated with long-term, event-free survival benefit. Percutaneous intervention treatment produced a borderline result (HR 0.78, 95% CI 0.61-1.00). However, the relationship...

  13. Recent progress in the development of Terumo implantable left ventricular assist system.

    Science.gov (United States)

    Nojiri, C; Kijima, T; Maekawa, J; Horiuchi, K; Kido, T; Sugiyama, T; Mori, T; Sugiura, N; Asada, T; Shimane, H; Ozaki, T; Suzuki, M; Akamatsu, T; Akutsu, T

    1999-01-01

    The research group of the Terumo Corporation, the NTN Corporation, and Setsunan University (T. Akamatsu) has been developing an implantable left ventricular assist system (ILVAS) featuring a centrifugal blood pump with a magnetically suspended impeller (MSCP). The impeller of the MSCP is suspended by a magnetic bearing, providing contact-free rotation of the impeller inside the pump housing. Thus the MSCP is expected to provide years of long-term durability. Ex vivo chronic sheep experiments using the extracorporeal model (Model I) demonstrated long-term durability, nonthrombogenicity, and a low hemolysis rate (plasma free Hb model (Model II; 196 ml, 400 g) was evaluated ex vivo in 2 sheep and intrathoracically implanted in a small sheep (45 kg). These experiments were terminated at 70, 79, and 17 days, respectively, because of blood leakage through the connector system within the housing of Model II. There was no thrombus formation on the retrieved pump surfaces. A new connector system was introduced to the Model II pump (modified Model II), and the pump was intrathoracically implanted in a sheep. Pump flow rate was maintained at 3-7 L/min at 1700-1800 rpm. The temperature elevation on the surfaces of the motor and the electromagnet inside the pump casing was kept less than 6 degrees C. The temperature of the tissue adjacent to the pump casing became normal 10 days postoperatively. The sheep survived for more than 5 months without any sign of mechanical failure or thromboembolic complication. In vitro real-time endurance tests of motor bearings made of stainless steel and silicone nitride have been conducted for more than 1 year without any sign of bearing wear. The next prototype system (Model III), with an implantable controller and a new MSCP with reduced input power, has been developed with a view toward a totally implantable LVAS.

  14. Photoelectrochemical solar cells based on Bi{sub 2}WO{sub 6}; Celdas solares fotoelectroquimicas basadas en Bi{sub 2}WO{sub 6}

    Energy Technology Data Exchange (ETDEWEB)

    Madriz, Lorean; Tata, Jose; Cuartas, Veronica; Cuellar, Alejandra; Vargas, Ronald, E-mail: lmadriz@usb.ve [Departamento de Quimica, Universidad Simon Bolivar, Caracas (Venezuela, Bolivarian Republic of)

    2014-04-15

    In this study, photoelectrochemical solar cells based on bismuth tungstate electrodes were evaluated. Bi{sub 2}WO{sub 6} was synthesized by a hydrothermal method and characterized by scanning electron microscopy, UV-Vis reflectance spectroscopy, and X-ray powder diffraction. For comparison, solar cells based on TiO{sub 2} semiconductor electrodes were evaluated. Photoelectrochemical response of Grätzel-type solar cells based on these semiconductors and their corresponding sensitization with two inexpensive phthalocyanines dyes were determined. Bi{sub 2}WO{sub 6}-based solar cells presented higher values of photocurrent and efficiency than those obtained with TiO{sub 2} electrodes, even without sensitization. These results portray solar cells based on Bi{sub 2}WO{sub 6} as promising devices for solar energy conversion owing to lower cost of production and ease of acquisition. (author)

  15. Diffractive optical devices produced by light-assisted trapping of nanoparticles.

    Science.gov (United States)

    Muñoz-Martínez, J F; Jubera, M; Matarrubia, J; García-Cabañes, A; Agulló-López, F; Carrascosa, M

    2016-01-15

    One- and two-dimensional diffractive optical devices have been fabricated by light-assisted trapping and patterning of nanoparticles. The method is based on the dielectrophoretic forces appearing in the vicinity of a photovoltaic crystal, such as Fe:LiNbO3, during or after illumination. By illumination with the appropriate light distribution, the nanoparticles are organized along patterns designed at will. One- and two-dimensional diffractive components have been achieved on X- and Z-cut Fe:LiNbO3 crystals, with their polar axes parallel and perpendicular to the crystal surface, respectively. Diffraction gratings with periods down to around a few micrometers have been produced using metal (Al, Ag) nanoparticles with radii in the range of 70-100 nm. Moreover, several 2D devices, such as Fresnel zone plates, have been also produced showing the potential of the method. The diffractive particle patterns remain stable when light is removed. A method to transfer the diffractive patterns to other nonphotovoltaic substrates, such as silica glass, has been also reported.

  16. Systolic ventricular filling.

    Science.gov (United States)

    Torrent-Guasp, Francisco; Kocica, Mladen J; Corno, Antonio; Komeda, Masashi; Cox, James; Flotats, A; Ballester-Rodes, Manel; Carreras-Costa, Francesc

    2004-03-01

    The evidence of the ventricular myocardial band (VMB) has revealed unavoidable coherence and mutual coupling of form and function in the ventricular myocardium, making it possible to understand the principles governing electrical, mechanical and energetical events within the human heart. From the earliest Erasistratus' observations, principal mechanisms responsible for the ventricular filling have still remained obscured. Contemporary experimental and clinical investigations unequivocally support the attitude that only powerful suction force, developed by the normal ventricles, would be able to produce an efficient filling of the ventricular cavities. The true origin and the precise time frame for generating such force are still controversial. Elastic recoil and muscular contraction were the most commonly mentioned, but yet, still not clearly explained mechanisms involved in the ventricular suction. Classical concepts about timing of successive mechanical events during the cardiac cycle, also do not offer understandable insight into the mechanism of the ventricular filling. The net result is the current state of insufficient knowledge of systolic and particularly diastolic function of normal and diseased heart. Here we summarize experimental evidence and theoretical backgrounds, which could be useful in understanding the phenomenon of the ventricular filling. Anatomy of the VMB, and recent proofs for its segmental electrical and mechanical activation, undoubtedly indicates that ventricular filling is the consequence of an active muscular contraction. Contraction of the ascendent segment of the VMB, with simultaneous shortening and rectifying of its fibers, produces the paradoxical increase of the ventricular volume and lengthening of its long axis. Specific spatial arrangement of the ascendent segment fibers, their interaction with adjacent descendent segment fibers, elastic elements and intra-cavitary blood volume (hemoskeleton), explain the physical principles

  17. Fabrication, Characterization, Properties, and Applications of Low-Dimensional BiFeO3 Nanostructures

    Directory of Open Access Journals (Sweden)

    Heng Wu

    2014-01-01

    Full Text Available Low-dimensional BiFeO3 nanostructures (e.g., nanocrystals, nanowires, nanotubes, and nanoislands have received considerable attention due to their novel size-dependent properties and outstanding multiferroic properties at room temperature. In recent years, much progress has been made both in fabrications and (microstructural, electrical, and magnetic in characterizations of BiFeO3 low-dimensional nanostructures. An overview of the state of art in BiFeO3 low-dimensional nanostructures is presented. First, we review the fabrications of high-quality BiFeO3 low-dimensional nanostructures via a variety of techniques, and then the structural characterizations and physical properties of the BiFeO3 low-dimensional nanostructures are summarized. Their potential applications in the next-generation magnetoelectric random access memories and photovoltaic devices are also discussed. Finally, we conclude this review by providing our perspectives to the future researches of BiFeO3 low-dimensional nanostructures and some key problems are also outlined.

  18. Auger recombination suppression and band alignment in GaAsBi/GaAs heterostructures

    Energy Technology Data Exchange (ETDEWEB)

    Hild, K.; Batool, Z.; Jin, S. R.; Hossain, N.; Marko, I. P.; Sweeney, S. J. [Advanced Technology Institute and Department of Physics, University of Surrey, Guildford, GU2 7XH (United Kingdom); Hosea, T. JC. [1 Advanced Technology Institute and Department of Physics, University of Surrey, Guildford, GU2 7XH, UK and also, Ibnu Sina Institute, Universiti Teknologi Malaysia, Johor Bahru, 81310 (Malaysia); Lu, X. [Department of Electrical and Computer Engineering, University of Victoria, Victoria BC, V8W 3P6, Canada and now VarianSemiconductor Equipment Associates, Gloucester, MA 01930 (United States); Tiedje, T. [Department of Electrical and Computer Engineering, University of Victoria, Victoria BC, V8W 3P6 (Canada)

    2013-12-04

    Using a combination of experimental and theoretical techniques we present the dependence of the bandgap E{sub g} and the spin orbit splitting energy Δ{sub so}, with Bi concentration in GaAsBi/GaAs samples. We find that the concentration at which Δ{sub so},> E{sub g} occurs at 9%. Both spectroscopic as well as first device results indicate a type I alignment.

  19. An Examination of the Impact of an Assistive Technology Device on the Quality of Adult/Young Child Interactions

    Science.gov (United States)

    Plunkett, Diane M.

    2013-01-01

    The purpose of this study was to gain greater understanding of the potential benefits of assistive technology (AT) devices on young children's social development. Specifically, changes to the quality of the adult/young child social interactions as a function of the child's access to and use of his/her personal AT device was examined. Using a…

  20. Left ventricular assist device therapy in advanced heart failure

    DEFF Research Database (Denmark)

    Gustafsson, Finn; Rogers, Joseph G

    2017-01-01

    Despite improvements in pharmacological therapy and pacing, prognosis in advanced heart failure (HF) remains poor, with a 1-year mortality of 25-50%. While heart transplantation provides excellent survival and quality of life for eligible patients, only a few can be offered this treatment due...

  1. Development of a power-assisted lifting device for construction and periodic inspection

    International Nuclear Information System (INIS)

    Hayatsu, M.; Yamada, M.; Takasu, H.; Tagawa, Y.; Kajiwara, K.

    2001-01-01

    This study focuses on the control system design and control performance of a power-assisted lifting device. The device consists of several electric chain-blocks, each controlled by force sensors and a CPU. The mechanism is as follows: (1) Force sensors detect any chain tension changes (by human force), (2) The CPU calculates the required output, (3) Electric chain-blocks move the object in the intended direction. The feature of this device is that it does not require any information related to the suspension points of the electric chain-blocks. The controller was designed using the H method, which considers disturbances and aims to provide robust stability under the operation conditions of construction verified through experiments using a 700 kg steel dummy mass (control object) suspended by four electric chain-blocks. In the experiments, the controller, which was designed using the H method, was compared to the PI controller method, and the effectiveness of the H controller was proven. A control object could be moved, translated, and rotated by human force (of less than 10 kg). Positioning performance errors were suppressed to less than 0.5 mm, and operation time was reduced by about 50%. This device will improve working efficiency and rationalize lifting operations in nuclear power plants. (author)

  2. Development of a power-assisted lifting device for construction and periodic inspection

    Energy Technology Data Exchange (ETDEWEB)

    Hayatsu, M.; Yamada, M.; Takasu, H. [Hitachi Plant Engineering and Construction, Chiba-ken (Japan); Tagawa, Y. [Tokyo Univ. of Agriculture and Technology (Japan); Kajiwara, K. [National Research Institute for Earth Science and Disaster Prevention, Tokyo (Japan)

    2001-07-01

    This study focuses on the control system design and control performance of a power-assisted lifting device. The device consists of several electric chain-blocks, each controlled by force sensors and a CPU. The mechanism is as follows: (1) Force sensors detect any chain tension changes (by human force), (2) The CPU calculates the required output, (3) Electric chain-blocks move the object in the intended direction. The feature of this device is that it does not require any information related to the suspension points of the electric chain-blocks. The controller was designed using the H method, which considers disturbances and aims to provide robust stability under the operation conditions of construction verified through experiments using a 700 kg steel dummy mass (control object) suspended by four electric chain-blocks. In the experiments, the controller, which was designed using the H method, was compared to the PI controller method, and the effectiveness of the H controller was proven. A control object could be moved, translated, and rotated by human force (of less than 10 kg). Positioning performance errors were suppressed to less than 0.5 mm, and operation time was reduced by about 50%. This device will improve working efficiency and rationalize lifting operations in nuclear power plants. (author)

  3. Impact of fixed pulmonary hypertension on post-heart transplant outcomes in bridge-to-transplant patients

    DEFF Research Database (Denmark)

    Alba, Ana Carolina; Rao, Vivek; Ross, Heather J

    2010-01-01

    Fixed pulmonary hypertension (FPH) is considered a contraindication to cardiac transplantation. Ventricular assist device (VAD) therapy through prolonged left ventricular unloading may reverse FPH. Our aim was to assess post-transplant outcomes and survival in patients with and without FPH...

  4. Formation of ZnSe/Bi2Se3 QDs by surface cation exchange and high photothermal conversion

    Directory of Open Access Journals (Sweden)

    Guozhi Jia

    2015-08-01

    Full Text Available Water-dispersed core/shell structure ZnSe/Bi2Se3 quantum dots were synthesized by ultrasonicwave-assisted cation exchange reaction. Only surface Zn ion can be replaced by Bi ion in ZnSe quantum dots, which lead to the ultrathin Bi2Se3 shell layer formed. It is significance to find to change the crystal of QDs due to the acting of ultrasonicwave. Cation exchange mechanism and excellent photothermal conversion properties are discussed in detail.

  5. Observation of hidden atomic order at the interface between Fe and topological insulator Bi2Te3.

    Science.gov (United States)

    Sánchez-Barriga, Jaime; Ogorodnikov, Ilya I; Kuznetsov, Mikhail V; Volykhov, Andrey A; Matsui, Fumihiko; Callaert, Carolien; Hadermann, Joke; Verbitskiy, Nikolay I; Koch, Roland J; Varykhalov, Andrei; Rader, Oliver; Yashina, Lada V

    2017-11-22

    To realize spintronic devices based on topological insulators (TIs), well-defined interfaces between magnetic metals and TIs are required. Here, we characterize atomically precisely the interface between the 3d transition metal Fe and the TI Bi 2 Te 3 at different stages of its formation. Using photoelectron diffraction and holography, we show that after deposition of up to 3 monolayers Fe on Bi 2 Te 3 at room temperature, the Fe atoms are ordered at the interface despite the surface disorder revealed by our scanning-tunneling microscopy images. We find that Fe occupies two different sites: a hollow adatom deeply relaxed into the Bi 2 Te 3 quintuple layers and an interstitial atom between the third (Te) and fourth (Bi) atomic layers. For both sites, our core-level photoemission spectra and density-functional theory calculations demonstrate simultaneous chemical bonding of Fe to both Te and Bi atoms. We further show that upon deposition of Fe up to a thickness of 20 nm, the Fe atoms penetrate deeper into the bulk forming a 2-5 nm interface layer containing FeTe. In addition, excessive Bi is pushed down into the bulk of Bi 2 Te 3 leading to the formation of septuple layers of Bi 3 Te 4 within a distance of ∼25 nm from the interface. Controlling the magnetic properties of the complex interface structures revealed by our work will be of critical importance when optimizing the efficiency of spin injection in TI-based devices.

  6. A brief intervention for at-risk drinking in an employee assistance program.

    Science.gov (United States)

    Osilla, Karen Chan; Zellmer, Steven P; Larimer, Mary E; Neighbors, Clayton; Marlatt, G Alan

    2008-01-01

    The current pilot study examined the preliminary efficacy of a brief intervention (BI) for at-risk drinking in an employee assistance program. Clients (N = 107) entering the employee assistance program (EAP) for mental health services were screened and met criteria for at-risk drinking. EAP therapists were randomly assigned to deliver either the BI plus EAP services as usual (SAU) or SAU only. Participants in the final analyses consisted of 44 BI + SAU (30 women, 14 men) and 30 SAU (21 women, 9 men) EAP clients who completed a 3-month follow-up. Results suggested that participants in the BI + SAU group had significant reductions in peak blood alcohol concentration, peak quantity, and alcohol-related consequences compared with the SAU group. Men in the BI + SAU group had greater reductions in alcohol-related problems compared with men in the SAU group. Groups did not differ by number of total EAP sessions attended or rates of presenting problem resolution. Results provide preliminary evidence to support the integration of alcohol screening and BI as a low-cost method of intervening with clients with at-risk drinking in the context of co-occurring presenting problems.

  7. Biomolecule-assisted hydrothermal synthesis of silver bismuth sulfide with nanostructures

    International Nuclear Information System (INIS)

    Kaowphong, Sulawan

    2012-01-01

    Silver bismuth sulfide (AgBiS 2 ) nanostructures were successfully prepared via a simple biomolecule-assisted hydrothermal synthesis at 200 °C for 12–72 h. Silver nitrate, bismuth nitrate and L-cysteine were used as starting materials. Here, the biomolecule, L-cysteine, was served as the sulfide source and a complexing agent. The products, characterized by X-ray powder diffraction (XRD), scanning electron microscopy (SEM) and transmission electron microscopy (TEM), were cubic AgBiS 2 nanoparticles with a diameter range of about 20–75 nm. It was found that their crystallinity and particle size increased with increasing reaction time. The energy dispersive X-ray spectroscopy (EDX) and inductively coupled plasma optical emission spectrophotometry (ICP-OES) analyses were used to confirm the stoichiometry of AgBiS 2 . The optical band gap of the AgBiS 2 nanoparticles, calculated from UV–vis spectra, was 3.0 eV which indicated a strong blue shift because of the quantum confinement effect. A possible formation mechanism of the AgBiS 2 nanoparticles was also discussed. - Graphical abstract: The optical band gap of the as-prepared AgBiS 2 nanoparticles displays a strong blue shift comparing to the 2.46 eV of bulk AgBiS 2 caused by the quantum confinement effects. Highlights: ► A simple biomolecule-assisted hydrothermal method is developed to prepare AgBiS 2 . ► L-Cysteine is served as the sulfide source and a complexing agent. ► Increase in band gap of the AgBiS 2 nanoparticles attributes to the quantum confinement effects.

  8. Bi-module sensing device to in situ quantitatively detect hydrogen peroxide released from migrating tumor cells.

    Directory of Open Access Journals (Sweden)

    Ling Yu

    Full Text Available Cell migration is one of the key cell functions in physiological and pathological processes, especially in tumor metastasis. However, it is not feasible to monitor the important biochemical molecules produced during cell migrations in situ by conventional cell migration assays. Herein, for the first time a device containing both electrochemical sensing and trans-well cell migration modules was fabricated to sensitively quantify biochemical molecules released from the cell migration process in situ. The fully assembled device with a multi-wall carbon nanotube/graphene/MnO2 nanocomposite functionalized electrode was able to successfully characterize hydrogen peroxide (H2O2 production from melanoma A375 cells, larynx carcinoma HEp-2 cells and liver cancer Hep G2 under serum established chemotaxis. The maximum concentration of H2O2 produced from A375, HEp-2 and Hep G2 in chemotaxis was 130 ± 1.3 nM, 70 ± 0.7 nM and 63 ± 0.7 nM, respectively. While the time required reaching the summit of H2O2 production was 3.0, 4.0 and 1.5 h for A375, HEp-2 and Hep G2, respectively. By staining the polycarbonate micropore membrane disassembled from the device, we found that the average migration rate of the A375, HEp-2 and Hep G2 cells were 98 ± 6%, 38 ± 4% and 32 ± 3%, respectively. The novel bi-module cell migration platform enables in situ investigation of cell secretion and cell function simultaneously, highlighting its potential for characterizing cell motility through monitoring H2O2 production on rare samples and for identifying underlying mechanisms of cell migration.

  9. CMOS and BiCMOS process integration and device characterization

    CERN Document Server

    El-Kareh, Badih

    2009-01-01

    Covers both the theoretical and practical aspects of modern silicon devices and the relationship between their electrical properties and processing conditions. This book also covers silicon devices and integrated process technologies. It discusses modern silicon devices, their characteristics, and interactions with process parameters.

  10. Unmappable ventricular tachycardia after an old myocardial infarction. Long-term results of substrate modification in patients with an implantable cardioverter defibrillator

    OpenAIRE

    Alzand, B. S. N.; Timmermans, C. C. M. M.; Wellens, H. J. J.; Dennert, R.; Philippens, S. A. M.; Portegijs, P. J. M.; Rodriguez, LM.

    2011-01-01

    Purpose The frequent occurrence of ventricular tachycardia can create a serious problem in patients with an implantable cardioverter defibrillator. We assessed the long-term efficacy of catheter-based substrate modification using the voltage mapping technique of infarct-related ventricular tachycardia and recurrent device therapy. Methods The study population consisted of 27 consecutive patients (age 68 ± 8 years, 25 men, mean left ventricular ejection fraction 31 ± 9%) with an old myocardial...

  11. Bi-articular Knee-Ankle-Foot Exoskeleton Produces Higher Metabolic Cost Reduction than Weight-Matched Mono-articular Exoskeleton

    Science.gov (United States)

    Malcolm, Philippe; Galle, Samuel; Derave, Wim; De Clercq, Dirk

    2018-01-01

    The bi-articular m. gastrocnemius and the mono-articular m. soleus have different and complementary functions during walking. Several groups are starting to use these biological functions as inspiration to design prostheses with bi-articular actuation components to replace the function of the m. gastrocnemius. Simulation studies indicate that a bi-articular configuration and spring that mimic the m. gastrocnemius could be beneficial for orthoses or exoskeletons. Our aim was to test the effect of a bi-articular and spring configuration that mimics the m. gastrocnemius and compare this to a no-spring and mono-articular configuration. We tested nine participants during walking with knee-ankle-foot exoskeletons with dorsally mounted pneumatic muscle actuators. In the bi-articular plus spring condition the pneumatic muscles were attached to the thigh segment with an elastic cord. In the bi-articular no-spring condition the pneumatic muscles were also attached to the thigh segment but with a non-elastic cord. In the mono-articular condition the pneumatic muscles were attached to the shank segment. We found the highest reduction in metabolic cost of 13% compared to walking with the exoskeleton powered-off in the bi-articular plus spring condition. Possible explanations for this could be that the exoskeleton delivered the highest total positive work in this condition at the ankle and the knee and provided more assistance during the isometric phase of the biological plantarflexors. As expected we found that the bi-articular conditions reduced m. gastrocnemius EMG more than the mono-articular condition but this difference was not significant. We did not find that the mono-articular condition reduces the m. soleus EMG more than the bi-articular conditions. Knowledge of specific effects of different exoskeleton configurations on metabolic cost and muscle activation could be useful for providing customized assistance for specific gait impairments. PMID:29551959

  12. Bi-articular Knee-Ankle-Foot Exoskeleton Produces Higher Metabolic Cost Reduction than Weight-Matched Mono-articular Exoskeleton

    Directory of Open Access Journals (Sweden)

    Philippe Malcolm

    2018-03-01

    Full Text Available The bi-articular m. gastrocnemius and the mono-articular m. soleus have different and complementary functions during walking. Several groups are starting to use these biological functions as inspiration to design prostheses with bi-articular actuation components to replace the function of the m. gastrocnemius. Simulation studies indicate that a bi-articular configuration and spring that mimic the m. gastrocnemius could be beneficial for orthoses or exoskeletons. Our aim was to test the effect of a bi-articular and spring configuration that mimics the m. gastrocnemius and compare this to a no-spring and mono-articular configuration. We tested nine participants during walking with knee-ankle-foot exoskeletons with dorsally mounted pneumatic muscle actuators. In the bi-articular plus spring condition the pneumatic muscles were attached to the thigh segment with an elastic cord. In the bi-articular no-spring condition the pneumatic muscles were also attached to the thigh segment but with a non-elastic cord. In the mono-articular condition the pneumatic muscles were attached to the shank segment. We found the highest reduction in metabolic cost of 13% compared to walking with the exoskeleton powered-off in the bi-articular plus spring condition. Possible explanations for this could be that the exoskeleton delivered the highest total positive work in this condition at the ankle and the knee and provided more assistance during the isometric phase of the biological plantarflexors. As expected we found that the bi-articular conditions reduced m. gastrocnemius EMG more than the mono-articular condition but this difference was not significant. We did not find that the mono-articular condition reduces the m. soleus EMG more than the bi-articular conditions. Knowledge of specific effects of different exoskeleton configurations on metabolic cost and muscle activation could be useful for providing customized assistance for specific gait impairments.

  13. Bi-articular Knee-Ankle-Foot Exoskeleton Produces Higher Metabolic Cost Reduction than Weight-Matched Mono-articular Exoskeleton.

    Science.gov (United States)

    Malcolm, Philippe; Galle, Samuel; Derave, Wim; De Clercq, Dirk

    2018-01-01

    The bi-articular m. gastrocnemius and the mono-articular m. soleus have different and complementary functions during walking. Several groups are starting to use these biological functions as inspiration to design prostheses with bi-articular actuation components to replace the function of the m. gastrocnemius. Simulation studies indicate that a bi-articular configuration and spring that mimic the m. gastrocnemius could be beneficial for orthoses or exoskeletons. Our aim was to test the effect of a bi-articular and spring configuration that mimics the m. gastrocnemius and compare this to a no-spring and mono-articular configuration. We tested nine participants during walking with knee-ankle-foot exoskeletons with dorsally mounted pneumatic muscle actuators. In the bi-articular plus spring condition the pneumatic muscles were attached to the thigh segment with an elastic cord. In the bi-articular no-spring condition the pneumatic muscles were also attached to the thigh segment but with a non-elastic cord. In the mono-articular condition the pneumatic muscles were attached to the shank segment. We found the highest reduction in metabolic cost of 13% compared to walking with the exoskeleton powered-off in the bi-articular plus spring condition . Possible explanations for this could be that the exoskeleton delivered the highest total positive work in this condition at the ankle and the knee and provided more assistance during the isometric phase of the biological plantarflexors. As expected we found that the bi-articular conditions reduced m. gastrocnemius EMG more than the mono-articular condition but this difference was not significant. We did not find that the mono-articular condition reduces the m. soleus EMG more than the bi-articular conditions . Knowledge of specific effects of different exoskeleton configurations on metabolic cost and muscle activation could be useful for providing customized assistance for specific gait impairments.

  14. Identification of tasks performed by stroke patients using a mobility assistive device

    DEFF Research Database (Denmark)

    Hester, Todd; Sherrill, Delsey M; Hamel, Mathieu

    2006-01-01

    of these devices. In this study, we propose the use of wearable sensors to identify tasks performed by stroke patients with a mobility assistive device. Subjects performed ten tasks with a three-axis accelerometer attached to their ankle and a neural network was trained to identify the task being performed...... tasks associated with the use of a cane. Therefore, we envision that the methodology presented in this paper could be used to evaluate the use of a cane in the context of the task being performed........ Results from 15 stroke patients indicated that these motor tasks can be reliably identified with a median sensitivity of 90 % at a median specificity of 95%. These results indicate that it is possible to use a single module with a three-axis accelerometer attached to the ankle to reliably identify motor...

  15. Grasp Assist Device with Shared Tendon Actuator Assembly

    Science.gov (United States)

    Ihrke, Chris A. (Inventor); Bergelin, Bryan J. (Inventor); Bridgwater, Lyndon (Inventor)

    2015-01-01

    A grasp assist device includes a glove with first and second tendon-driven fingers, a tendon, and a sleeve with a shared tendon actuator assembly. Tendon ends are connected to the respective first and second fingers. The actuator assembly includes a drive assembly having a drive axis and a tendon hook. The tendon hook, which defines an arcuate surface slot, is linearly translatable along the drive axis via the drive assembly, e.g., a servo motor thereof. The flexible tendon is routed through the surface slot such that the surface slot divides the flexible tendon into two portions each terminating in a respective one of the first and second ends. The drive assembly may include a ball screw and nut. An end cap of the actuator assembly may define two channels through which the respective tendon portions pass. The servo motor may be positioned off-axis with respect to the drive axis.

  16. Memory-assisted measurement-device-independent quantum key distribution

    Science.gov (United States)

    Panayi, Christiana; Razavi, Mohsen; Ma, Xiongfeng; Lütkenhaus, Norbert

    2014-04-01

    A protocol with the potential of beating the existing distance records for conventional quantum key distribution (QKD) systems is proposed. It borrows ideas from quantum repeaters by using memories in the middle of the link, and that of measurement-device-independent QKD, which only requires optical source equipment at the user's end. For certain memories with short access times, our scheme allows a higher repetition rate than that of quantum repeaters with single-mode memories, thereby requiring lower coherence times. By accounting for various sources of nonideality, such as memory decoherence, dark counts, misalignment errors, and background noise, as well as timing issues with memories, we develop a mathematical framework within which we can compare QKD systems with and without memories. In particular, we show that with the state-of-the-art technology for quantum memories, it is potentially possible to devise memory-assisted QKD systems that, at certain distances of practical interest, outperform current QKD implementations.

  17. Memory-assisted measurement-device-independent quantum key distribution

    International Nuclear Information System (INIS)

    Panayi, Christiana; Razavi, Mohsen; Ma, Xiongfeng; Lütkenhaus, Norbert

    2014-01-01

    A protocol with the potential of beating the existing distance records for conventional quantum key distribution (QKD) systems is proposed. It borrows ideas from quantum repeaters by using memories in the middle of the link, and that of measurement-device-independent QKD, which only requires optical source equipment at the user's end. For certain memories with short access times, our scheme allows a higher repetition rate than that of quantum repeaters with single-mode memories, thereby requiring lower coherence times. By accounting for various sources of nonideality, such as memory decoherence, dark counts, misalignment errors, and background noise, as well as timing issues with memories, we develop a mathematical framework within which we can compare QKD systems with and without memories. In particular, we show that with the state-of-the-art technology for quantum memories, it is potentially possible to devise memory-assisted QKD systems that, at certain distances of practical interest, outperform current QKD implementations. (paper)

  18. Normal left ventricular emptying in coronary artery disease at rest: analysis by radiographic and equilibrium radionuclide ventriculography

    International Nuclear Information System (INIS)

    Denenberg, B.S.; Makler, P.T.; Bove, A.A.; Spann, J.F.

    1981-01-01

    The volume ejected early in systole has been proposed as an indicator of abnormal left ventricular function that is present at rest in patients with coronary artery disease with a normal ejection fraction and normal wall motion. The volume ejected in systole was examined by calculating the percent change in ventricular volume using both computer-assisted analysis of biplane radiographic ventriculograms at 60 frames/s and equilibrium gated radionuclide ventriculograms. Ventricular emptying was examined with radiographic ventriculography in 33 normal patients and 23 patients with coronary artery disease and normal ejection fraction. Eight normal subjects and six patients with coronary artery disease had both radiographic ventriculography and equilibrium gated radionuclide ventriculography. In all patients, there was excellent correlation between the radiographic and radionuclide ventricular emptying curves (r . 0.971). There were no difference in the ventricular emptying curves of normal subjects and patients with coronary artery disease whether volumes were measured by radiographic or equilibrium gated radionuclide ventriculography. It is concluded that the resting ventricular emptying curves are identical in normal subjects and patients with coronary artery disease who have a normal ejection fraction and normal wall motion

  19. Bi-Force

    DEFF Research Database (Denmark)

    Sun, Peng; Speicher, Nora K; Röttger, Richard

    2014-01-01

    of pairwise similarities. We first evaluated the power of Bi-Force to solve dedicated bicluster editing problems by comparing Bi-Force with two existing algorithms in the BiCluE software package. We then followed a biclustering evaluation protocol in a recent review paper from Eren et al. (2013) (A...... comparative analysis of biclustering algorithms for gene expressiondata. Brief. Bioinform., 14:279-292.) and compared Bi-Force against eight existing tools: FABIA, QUBIC, Cheng and Church, Plaid, BiMax, Spectral, xMOTIFs and ISA. To this end, a suite of synthetic datasets as well as nine large gene expression...

  20. 21 CFR 884.6130 - Assisted reproduction microtools.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Assisted reproduction microtools. 884.6130 Section... (CONTINUED) MEDICAL DEVICES OBSTETRICAL AND GYNECOLOGICAL DEVICES Assisted Reproduction Devices § 884.6130 Assisted reproduction microtools. (a) Identification. Assisted reproduction microtools are pipettes or...